CERENT-GENERIC-MIB

992 objects
This module provides the definitions for generic objects and notifications of Cisco ONS network device, ONS 15327, 15310.
OIDNameAccessStatusDescription
1.3.6.1.4.1.3607.1.10.40IdentitycerentGenericMibModuleThis module provides the definitions for generic objects and notifications of Cisco ONS network device, ONS 15327, 15310.
1.3.6.1.4.1.3607.2.10IdentitycerentGenericObjectscurrentAll the generic objects definitions are grouped under this
1.3.6.1.4.1.3607.2.10.10IdentitycerentGenericCommonObjectsGroupcurrentThe group to combine all the Cisco OTBU common objects
1.3.6.1.4.1.3607.2.10.10.10ScalarcerentGenericEnableNotificationread-writecurrentThis variable indicates whether the system produces notifications. A value=FALSE will prevent notifications from being sent by this system.
1.3.6.1.4.1.3607.2.10.10.20ScalarcerentGenericNodeTimeread-onlycurrentIndicates current local time as reflected by the Cisco OTBU equipment. The format this scalar is YYYYMMDDhhmmss{S/D}. E.g., 20011103133453D means 1:34:53 PM PD…
1.3.6.1.4.1.3607.2.10.10.30ScalarcerentGenericSentNotificationsread-onlycurrentA count of v1+v2 notifications sent out by the agent. Resets to zero after cold/warm start.
1.3.6.1.4.1.3607.2.10.10.40ScalarcerentGenericLastChangeTimeread-onlycurrentThe value of sysUpTime at the time a conceptual row is created or deleted in cerentGenericAlarmTable
1.3.6.1.4.1.3607.2.10.10.50ScalarcerentGenericMultishelfEnabledread-onlycurrentThis variable indicates whether the system is configured in multi-shelf mode or single-shelf mode.
1.3.6.1.4.1.3607.2.10.20IdentitycerentGenericGeneralGroupcurrentAnother class of objects found in Cisco ONS 15327, 15310
1.3.6.1.4.1.3607.2.10.20.10ScalarcerentGenericSoftwareVersionread-onlycurrentIndicates the version of software that is used in Cisco ONS Network element, ONS 15327, 15310. E.g., 2.2.03
1.3.6.1.4.1.3607.2.10.30IdentitycerentGenericAlarmGroupcurrentThe group that will represent all the alarm info in the Cisco ONS network element, ONS 15327, 15310
1.3.6.1.4.1.3607.2.10.30.10ScalarcerentGenericAlarmCountread-onlycurrentTotal number of active alarms in the Cisco ONS network element, ONS 15327, 15310. This equals the total number of rows in cerentGenericAlarmTable at any time.
1.3.6.1.4.1.3607.2.10.30.20TablecerentGenericAlarmTablenot-accessiblecurrentThis table has all currently raised conditions for the network node. A Condition is a fault or status detected by hardware or software.
1.3.6.1.4.1.3607.2.10.30.20.1RowcerentGenericAlarmEntrynot-accessiblecurrentRow definition for cerentGenericAlarmTable
1.3.6.1.4.1.3607.2.10.30.20.1.10ColumncerentGenericAlarmIndexnot-accessiblecurrentUniquely identifies each entry in alarm table. May not start with one and there may be some missing numbers.
1.3.6.1.4.1.3607.2.10.30.20.1.20ColumncerentGenericAlarmObjectTyperead-onlycurrentThis will indicate what is the type of the entity which raised this alarm. ( E.g., DS3, etherBridge, VT-TERM, etc ) The NMS is expected to use this value to de…
1.3.6.1.4.1.3607.2.10.30.20.1.30ColumncerentGenericAlarmSlotNumberread-onlycurrentThis will indicate what is the slot of the object which raised this alarm. If not relevant to the alarm, will be zero.
1.3.6.1.4.1.3607.2.10.30.20.1.40ColumncerentGenericAlarmPortNumberread-onlycurrentThis will indicate what is the port of the object which raised this alarm.
1.3.6.1.4.1.3607.2.10.30.20.1.50ColumncerentGenericAlarmLineNumberread-onlycurrentThis will indicate what is the port of the object which raised this alarm. If not relevant to the alarm, will be zero.
1.3.6.1.4.1.3607.2.10.30.20.1.60ColumncerentGenericAlarmObjectIndexread-onlycurrentEvery alarm is raised by an object and this object is an entry in a specific table. This is the index of the object in that table E.g., if the alarm is interfa…
1.3.6.1.4.1.3607.2.10.30.20.1.70ColumncerentGenericAlarmTyperead-onlycurrentIndicates what the exact nature of the alarm. See the CerentGenericAlarmType TC for mapping details
1.3.6.1.4.1.3607.2.10.30.20.1.80ColumncerentGenericAlarmStateread-onlycurrentSpecifies alarm severity and service affecting status ( SA/NSA ). Only {minor|major|critical}+{NA|NSA} alarms and standing conditions will be represented here.…
1.3.6.1.4.1.3607.2.10.30.20.1.90ColumncerentGenericAlarmTimeStampread-onlycurrentThe value of sysUpTime when this entry was created. This is accurate only upto a second.
1.3.6.1.4.1.3607.2.10.30.20.1.100ColumncerentGenericAlarmObjectNameread-onlycurrentTL1-style user-visible name which uniquely identifies an object in the system
1.3.6.1.4.1.3607.2.10.30.20.1.110ColumncerentGenericAlarmAdditionalInforead-onlycurrentAdditional information for the alarm object. In the current version of the MIB, this object contains the following information :- a) Provisioned description fo…
1.3.6.1.4.1.3607.2.10.30.20.1.120ColumncerentGenericAlarmSeverityread-onlycurrentSpecifies severity of the alarm being sent out.
1.3.6.1.4.1.3607.2.10.30.20.1.130ColumncerentGenericAlarmStatusread-onlycurrentRepresents if an alarm is currently raised or cleared.
1.3.6.1.4.1.3607.2.10.30.20.1.140ColumncerentGenericAlarmServiceAffectingread-onlycurrentSpecifies whether the alarm that is being sent out is Service Affecting (SA) or Non- Service Affecting (NSA).
1.3.6.1.4.1.3607.2.10.30.30ScalarcerentGenericReportedAlarmCountread-onlycurrentNumber of alarms currently reported against Cisco ONS platform. This equals the number of rows in cerentGenericReportedAlarmTable.
1.3.6.1.4.1.3607.2.10.30.40TablecerentGenericReportedAlarmTablenot-accessiblecurrentThis table has the list of alarms currently reported for the Cisco ONS node. It does not include any cleared alarms. The alarms in this table are in compliance…
1.3.6.1.4.1.3607.2.10.30.40.1RowcerentGenericReportedAlarmEntrynot-accessiblecurrentRow definition for cerentGenericReportedAlarmTable
1.3.6.1.4.1.3607.2.10.30.40.1.10ColumncerentGenericReportedAlarmIndexnot-accessiblecurrentIdentifies each entry in ReportedAlarm table. May not start with one and there may be some missing numbers.
1.3.6.1.4.1.3607.2.10.30.40.1.20ColumncerentGenericReportedAlarmObjectTyperead-onlycurrentThis will indicate the type of the entity which raised this alarm. ( E.g., DS3, etherBridge, VT-TERM, etc ) The NMS is expected to use this value to decide whi…
1.3.6.1.4.1.3607.2.10.30.40.1.30ColumncerentGenericReportedAlarmSlotNumberread-onlycurrentThis will indicate what is the slot of the object which raised this alarm. If not relevant to the alarm, will be zero.
1.3.6.1.4.1.3607.2.10.30.40.1.40ColumncerentGenericReportedAlarmPortNumberread-onlycurrentThis will indicate what is the port of the object which raised this alarm.
1.3.6.1.4.1.3607.2.10.30.40.1.50ColumncerentGenericReportedAlarmObjectIndexread-onlycurrentEvery alarm is raised by an object and this object is an entry in a specific table. This is the index of the object in that table E.g., if the alarm is interfa…
1.3.6.1.4.1.3607.2.10.30.40.1.60ColumncerentGenericReportedAlarmTyperead-onlycurrentIndicates the exact nature of the alarm.
1.3.6.1.4.1.3607.2.10.30.40.1.70ColumncerentGenericReportedAlarmTimeStampread-onlycurrentThe value of sysUpTime when this entry was created. This is accurate only upto a second.
1.3.6.1.4.1.3607.2.10.30.40.1.80ColumncerentGenericReportedAlarmObjectNameread-onlycurrentTL1-style user-visible name which uniquely identifies an object in the system
1.3.6.1.4.1.3607.2.10.30.40.1.90ColumncerentGenericReportedAlarmAdditionalInforead-onlycurrentAdditional information for the alarm object. In the current version of the MIB, this object contains the following information :- a) Provisioned description fo…
1.3.6.1.4.1.3607.2.10.30.40.1.100ColumncerentGenericReportedAlarmSeverityread-onlycurrentSpecifies severity of the alarm.
1.3.6.1.4.1.3607.2.10.30.40.1.110ColumncerentGenericReportedAlarmStatusread-onlycurrentRepresents if the alarm is currently raised or cleared.
1.3.6.1.4.1.3607.2.10.30.40.1.120ColumncerentGenericReportedAlarmServiceAffectingread-onlycurrentSpecifies whether the alarm that is being sent out is Service Affecting (SA) or Non- Service Affecting (NSA).
1.3.6.1.4.1.3607.2.10.40IdentitycerentGenericThresholdGroupcurrentThe group that will represent all the threshold info in the Cisco ONS network element, ONS 15327, 15310
1.3.6.1.4.1.3607.2.10.40.10TablecerentGenericThresholdTablenot-accessiblecurrentThis table holds all the provisioned Thresholds. This table is currently unimplemented.
1.3.6.1.4.1.3607.2.10.40.10.1RowcerentGenericThresholdEntrynot-accessiblecurrentRow definition for cerentGenericThresholdTable
1.3.6.1.4.1.3607.2.10.40.10.1.10ColumncerentGenericThresholdIndexnot-accessiblecurrentUniquely identifies each entry in Threshold table. May not start with one and there will be some missing numbers.
1.3.6.1.4.1.3607.2.10.40.10.1.20ColumncerentGenericThresholdMonitorTyperead-onlycurrentThis object indicates the type of metric monitored.
1.3.6.1.4.1.3607.2.10.40.10.1.30ColumncerentGenericThresholdLocationread-onlycurrentThis indicates if it near or far end
1.3.6.1.4.1.3607.2.10.40.10.1.40ColumncerentGenericThresholdPeriodread-onlycurrentThe sampling interval period is indicated here
1.3.6.1.4.1.3607.2.10.40.10.1.50ColumncerentGenericThresholdSetValueread-onlycurrentThe value of this object will be threshold that was provisioned by the NMS
1.3.6.1.4.1.3607.2.10.40.10.1.60ColumncerentGenericThresholdCurrentValueread-onlycurrentThe current value of the counter which measures the metric. This column will never be implemented as these values are already accessible through IETF MIB objec…
1.3.6.1.4.1.3607.2.10.40.10.1.70ColumncerentGenericThresholdDetectTyperead-onlycurrentThe value of this object will be the detect type for the threshold.
1.3.6.1.4.1.3607.2.20IdentitycerentGenericEventscurrentPlace holder for all notifications of Cisco ONS network device, ONS 15327, 15310
1.3.6.1.4.1.3607.2.20.0IdentitycerentGenericV2EventscurrentThe sub-identifier has to be zero, as part of the interoperability agreement between SNMPv1 and SNMPv2 worlds.
1.3.6.1.4.1.3607.2.20.0.1NotificationgalarmUnknowncurrentalarm unknown
1.3.6.1.4.1.3607.2.20.0.10NotificationgalarmCutoffIsInManualModecurrentalarm cutoff is in manual mode
1.3.6.1.4.1.3607.2.20.0.20NotificationgfailureDetectedExternalToTheNEcurrentfailure detected External to the NE
1.3.6.1.4.1.3607.2.20.0.30NotificationgexternalErrorcurrentexternal error
1.3.6.1.4.1.3607.2.20.0.40NotificationgexcessiveSwitchingcurrentexcessive switching
1.3.6.1.4.1.3607.2.20.0.50NotificationgsdccTerminationFailurecurrentSDCC Termination failure
1.3.6.1.4.1.3607.2.20.0.60NotificationgincomingFailureConditioncurrentincoming failure condition
1.3.6.1.4.1.3607.2.20.0.70NotificationgalarmIndicationSignalcurrentalarm indication signal
1.3.6.1.4.1.3607.2.20.0.80NotificationgalarmIndicationSignalLinecurrentalarm indication signal LINE
1.3.6.1.4.1.3607.2.20.0.90NotificationgalarmIndicationSignalPathcurrentalarm indication signal Path
1.3.6.1.4.1.3607.2.20.0.100NotificationgalarmIndicationSignalVTcurrentalarm indication signal VT
1.3.6.1.4.1.3607.2.20.0.110NotificationgapsChannelFailurecurrentchannel failure APS
1.3.6.1.4.1.3607.2.20.0.120NotificationgchannelByteFailureAPScurrentchannel Byte failure APS
1.3.6.1.4.1.3607.2.20.0.130NotificationgchannelProtectionSwitchingChannelMatchFailureAPScurrentchannel Protection Switching Channel Match failure APS
1.3.6.1.4.1.3607.2.20.0.140NotificationgchannelAutomaticProtectionSwitchModeMismatchAPScurrentchannel Automatic Protection Switch Mode Mismatch APS
1.3.6.1.4.1.3607.2.20.0.150NotificationgfarEndProtectionLineFailurecurrentchannel far end protection line failure APS
1.3.6.1.4.1.3607.2.20.0.160NotificationginconsistentAPSCodecurrentInconsistent APS code
1.3.6.1.4.1.3607.2.20.0.170NotificationgimproperAPSCodecurrentImproper APS code APS
1.3.6.1.4.1.3607.2.20.0.180NotificationgnodeIdMismatchcurrentNode Id Mismatch APS
1.3.6.1.4.1.3607.2.20.0.190NotificationgchannelDefaultKAPScurrentDefault K APS
1.3.6.1.4.1.3607.2.20.0.200NotificationgconnectionLosscurrentConnection loss APS
1.3.6.1.4.1.3607.2.20.0.210NotificationgbipolarViolationcurrentbipolar Violation
1.3.6.1.4.1.3607.2.20.0.220NotificationgcarrierLossOnTheLANcurrentcarrier Loss on the LAN
1.3.6.1.4.1.3607.2.20.0.230NotificationgconcatenationErrorSTScurrentconcatenation error STS
1.3.6.1.4.1.3607.2.20.0.240NotificationgexcessCollisionsOnTheLANcurrentexcess collisions on the LAN
1.3.6.1.4.1.3607.2.20.0.250NotificationgfacilityFailurecurrentfacility critical alarm caused by DS3 facility failure
1.3.6.1.4.1.3607.2.20.0.260NotificationgfarEndAIScurrentfar end AIS
1.3.6.1.4.1.3607.2.20.0.270NotificationgfarEndMultipleDS1LOSDetectedOnDS3currentfar end Multiple DS1 LOS detected on DS3
1.3.6.1.4.1.3607.2.20.0.280NotificationgfarEndDS1EqptFailNonServiceAffectingcurrentfar end DS1 eqpt fail non service affecting
1.3.6.1.4.1.3607.2.20.0.290NotificationgfarEndDS1EqptFailServiceAffectingcurrentfar end DS1 Eqpt fail service affecting
1.3.6.1.4.1.3607.2.20.0.300NotificationgfarEndSingleDS1LOScurrentfar end Single DS1 LOS
1.3.6.1.4.1.3607.2.20.0.310NotificationgfarEndDS3EqptFailNonServiceAffectingcurrentfar end DS3 Eqpt failure non service affecting
1.3.6.1.4.1.3607.2.20.0.320NotificationgfarEndDS3EqptFailServiceAffectingcurrentfar end DS3 Eqpt failure service affecting
1.3.6.1.4.1.3607.2.20.0.330NotificationgfarEndCommonEquipmentFailureNonServiceAffectingcurrentfar end common Eqpt failure non service affecting
1.3.6.1.4.1.3607.2.20.0.340NotificationgfarEndIDLEcurrentfar end IDLE
1.3.6.1.4.1.3607.2.20.0.350NotificationgfarEndLOScurrentfar end LOS
1.3.6.1.4.1.3607.2.20.0.360NotificationgfarEndLOFcurrentfar end LOF
1.3.6.1.4.1.3607.2.20.0.370NotificationgfarEndBlockErrorcurrentfar End Block Error
1.3.6.1.4.1.3607.2.20.0.380Notificationgds3IdleConditioncurrentidle Condition DS3
1.3.6.1.4.1.3607.2.20.0.390NotificationglossOfFramecurrentloss of Frame
1.3.6.1.4.1.3607.2.20.0.400NotificationglossOfPointercurrentloss of Pointer
1.3.6.1.4.1.3607.2.20.0.410NotificationglossOfPointerPathcurrentloss of Pointer Path
1.3.6.1.4.1.3607.2.20.0.420NotificationglossOfPointerVTcurrentloss of Pointer VT
1.3.6.1.4.1.3607.2.20.0.430NotificationglossOfSignalcurrentloss of Signal
1.3.6.1.4.1.3607.2.20.0.440NotificationgoutOfFramecurrentout of Frame
1.3.6.1.4.1.3607.2.20.0.450NotificationgpathSelectorFailurecurrentpath Selector inability to swtich to a valid signal
1.3.6.1.4.1.3607.2.20.0.460NotificationgremoteAlarmIndicationcurrentremote Alarm Indication
1.3.6.1.4.1.3607.2.20.0.470NotificationgremoteFailureIndicationcurrentremote Failure Indication
1.3.6.1.4.1.3607.2.20.0.480NotificationgremoteFailureIndicationLinecurrentremote Failure Indication LINE
1.3.6.1.4.1.3607.2.20.0.490NotificationgremoteFailureIndicationPathcurrentremote Failure Indication Path
1.3.6.1.4.1.3607.2.20.0.500NotificationgremoteFailureIndicationVTcurrentremote Failure Indication VT
1.3.6.1.4.1.3607.2.20.0.510NotificationgsignalDegradecurrentSignal Degrade
1.3.6.1.4.1.3607.2.20.0.520NotificationgseverelyErroredFramecurrentseverely Errored Frame
1.3.6.1.4.1.3607.2.20.0.530NotificationgsignalFailurecurrentSignal Failure
1.3.6.1.4.1.3607.2.20.0.540NotificationgsignalLabelMismatchFailurecurrentsignal Label Mismatch Failures
1.3.6.1.4.1.3607.2.20.0.550NotificationgpayloadDefectIndicationcurrentPayload Defect Indication
1.3.6.1.4.1.3607.2.20.0.560NotificationgpayloadDefectIndicationPathcurrentPayload Defect Indication - Path
1.3.6.1.4.1.3607.2.20.0.570NotificationgpayloadLabelMismatchPathcurrentPayload Label Mismatch - Path
1.3.6.1.4.1.3607.2.20.0.580NotificationgsignalLabelMismatchFailurePayloadLabelMismatchVTcurrentsignal Label Mismatch Failure Payload Label Mismatch VT
1.3.6.1.4.1.3607.2.20.0.590NotificationgunequippedPathcurrentUnequipped - Path
1.3.6.1.4.1.3607.2.20.0.600NotificationgsignalLabelMismatchFailureUnequippedVTcurrentsignal Label Mismatch Failure Unequipped VT
1.3.6.1.4.1.3607.2.20.0.610NotificationglossOfSynchronizationcurrentLoss of Synchronization
1.3.6.1.4.1.3607.2.20.0.620NotificationgoutOfSynchronizationcurrentOut of Synchronization
1.3.6.1.4.1.3607.2.20.0.630NotificationgprimarySynchronizationReferenceFailurecurrentPrimary Synchronization Reference Failure
1.3.6.1.4.1.3607.2.20.0.640NotificationgsecondarySynchronizationReferenceFailurecurrentSecondary Synchronization Reference Failure
1.3.6.1.4.1.3607.2.20.0.650NotificationgthirdSynchronizationReferenceFailurecurrentThird Synchronization Reference Failure
1.3.6.1.4.1.3607.2.20.0.660NotificationgfourthSynchronizationReferenceFailurecurrentFourth Synchronization Reference Failure
1.3.6.1.4.1.3607.2.20.0.670NotificationgfifthSynchronizationReferenceFailurecurrentFifth Synchronization Reference Failure
1.3.6.1.4.1.3607.2.20.0.680NotificationgsixthSynchronizationReferenceFailurecurrentSixth Synchronization Reference Failure
1.3.6.1.4.1.3607.2.20.0.690NotificationgfailedToReceiveSynchronizationStatusMessagecurrentfailed to receive Synchronization Status Message
1.3.6.1.4.1.3607.2.20.0.700NotificationgsynchronizationStatusMessagesAreDisabledOnThisInterfacecurrentsynchronization Status Messages are disabled on this interface
1.3.6.1.4.1.3607.2.20.0.710Notificationgstratum1PrimaryReferenceSourceTraceablecurrentStratum1 Primary Reference Source Traceable
1.3.6.1.4.1.3607.2.20.0.720NotificationgsynchronizedTraceabilityUnknowncurrentsynchronized Traceability Unknown
1.3.6.1.4.1.3607.2.20.0.730Notificationgstratum2Traceablecurrentstratum 2 Traceable
1.3.6.1.4.1.3607.2.20.0.740NotificationgtransitNodeClockTraceablecurrenttransit Node clock Traceable
1.3.6.1.4.1.3607.2.20.0.750Notificationgstratum3ETraceablecurrentstratum 3E Traceable
1.3.6.1.4.1.3607.2.20.0.760Notificationgstratum3Traceablecurrentstratum 3 Traceable
1.3.6.1.4.1.3607.2.20.0.770NotificationgsonetMinimumClockTraceablecurrentMinimum clock Traceable - SONET
1.3.6.1.4.1.3607.2.20.0.780Notificationgstratum4Traceablecurrentstratum 4 Traceable
1.3.6.1.4.1.3607.2.20.0.790NotificationgdoNotUseForSynchronizationcurrentdo not Use for Synchronization
1.3.6.1.4.1.3607.2.20.0.800NotificationgreservedForNetworkSynchronizationUsecurrentreserved for Network Synchronization Use
1.3.6.1.4.1.3607.2.20.0.810NotificationgoutgoingFailureConditioncurrentoutgoing failure condition
1.3.6.1.4.1.3607.2.20.0.820NotificationgremoteDefectIndicationLinecurrentremote Defect Indication LINE
1.3.6.1.4.1.3607.2.20.0.830NotificationgremoteDefectIndicationPathcurrentremote Defect Indication Path
1.3.6.1.4.1.3607.2.20.0.840NotificationgfreeRunningSynchronizationModecurrentfree Running Synchronization mode
1.3.6.1.4.1.3607.2.20.0.850NotificationgholdoverSynchronizationModecurrentholdover synchronization mode
1.3.6.1.4.1.3607.2.20.0.860NotificationgfastStartSynchronizationModecurrentfast Start synchronization mode
1.3.6.1.4.1.3607.2.20.0.870NotificationginternalFaultcurrentinternal hardware fault or failure
1.3.6.1.4.1.3607.2.20.0.880NotificationginternalErrorcurrenterror Internal to the NE Detected
1.3.6.1.4.1.3607.2.20.0.890NotificationginternalMessageErrorcurrentinternal Message Error
1.3.6.1.4.1.3607.2.20.0.900NotificationgmismatchOfEquipmentAndAttributescurrentmismatch of Equipment and Attributes
1.3.6.1.4.1.3607.2.20.0.910NotificationgwatchdogTimerTimeoutcurrentwatchdog Timer Timeout
1.3.6.1.4.1.3607.2.20.0.920NotificationgsoftwareFaultOrFailurecurrentsoftware Fault or failure
1.3.6.1.4.1.3607.2.20.0.930NotificationgsoftwareFaultDataIntegrityFaultcurrentsoftware Fault - Data integrity fault : The newly added provisioning or hardware has caused the database to grow beyond its limit. That is, the newly added obj…
1.3.6.1.4.1.3607.2.20.0.940NotificationgprogramFailurecurrentprogram failure
1.3.6.1.4.1.3607.2.20.0.950NotificationgcontrolEquipmentFailurecurrentcontrol Equipment failure
1.3.6.1.4.1.3607.2.20.0.960NotificationgprimaryNonVolatileBackupMemoryFailurecurrentcontrol Equipment Primary non volatile Backup Memory failure
1.3.6.1.4.1.3607.2.20.0.970NotificationgsecondaryNonVolatileBackupMemoryFailurecurrentcontrol Equipment Secondary non volatile Backup Memory failure
1.3.6.1.4.1.3607.2.20.0.980NotificationgcontrolBusFailurecurrentcontrol Equipment Control Bus failure
1.3.6.1.4.1.3607.2.20.0.990NotificationgcontrolBus1Failurecurrentcontrol Equipment Control Bus 1 failure
1.3.6.1.4.1.3607.2.20.0.1000NotificationgcontrolBus2Failurecurrentcontrol Equipment Control Bus 2 failure
1.3.6.1.4.1.3607.2.20.0.1010NotificationgtccAToShelfSlot1DROP1CommunicationFailurecurrentcommunication failure Controller A to Shelf SLOT 1
1.3.6.1.4.1.3607.2.20.0.1020NotificationgtccAToShelfSlot2DROP2CommunicationFailurecurrentcommunication failure Controller A to Shelf SLOT 2
1.3.6.1.4.1.3607.2.20.0.1030NotificationgtccAToShelfSlot3DROP3CommunicationFailurecurrentcommunication failure Controller A to Shelf SLOT 3
1.3.6.1.4.1.3607.2.20.0.1040NotificationgtccAToShelfSlot4DROP4CommunicationFailurecurrentcommunication failure Controller A to Shelf SLOT 4
1.3.6.1.4.1.3607.2.20.0.1050NotificationgtccAToShelfSlot5TRUNK1CommunicationFailurecurrentcommunication failure Controller A to Shelf SLOT 5
1.3.6.1.4.1.3607.2.20.0.1060NotificationgtccAToShelfSlot6TRUNK2CommunicationFailurecurrentcommunication failure Controller A to Shelf SLOT 6
1.3.6.1.4.1.3607.2.20.0.1070NotificationgtccAToShelfSlot7TCCACommunicationFailurecurrentcommunication failure Controller A to Shelf SLOT 7
1.3.6.1.4.1.3607.2.20.0.1080NotificationgtccAToShelfSlot8XCONACommunicationFailurecurrentcommunication failure Controller A to Shelf SLOT 8
1.3.6.1.4.1.3607.2.20.0.1090NotificationgtccAToShelfSlot9AICCommunicationFailurecurrentcommunication failure Controller A to Shelf SLOT 9
1.3.6.1.4.1.3607.2.20.0.1100NotificationgtccAToShelfSlot10XCONBCommunicationFailurecurrentcommunication failure Controller A to Shelf SLOT 10
1.3.6.1.4.1.3607.2.20.0.1110NotificationgtccAToShelfSlot11TCCBCommunicationFailurecurrentcommunication failure Controller A to Shelf SLOT 11
1.3.6.1.4.1.3607.2.20.0.1120NotificationgtccAToShelfSlot12TRUNK3CommunicationFailurecurrentcommunication failure Controller A to Shelf SLOT 12
1.3.6.1.4.1.3607.2.20.0.1130NotificationgtccAToShelfSlot13TRUNK4CommunicationFailurecurrentcommunication failure Controller A to Shelf SLOT 13
1.3.6.1.4.1.3607.2.20.0.1140NotificationgtccAToShelfSlot14DROP5CommunicationFailurecurrentcommunication failure Controller A to Shelf SLOT 14
1.3.6.1.4.1.3607.2.20.0.1150NotificationgtccAToShelfSlot15DROP6CommunicationFailurecurrentcommunication failure Controller A to Shelf SLOT 15
1.3.6.1.4.1.3607.2.20.0.1160NotificationgtccAToShelfSlot16DROP7CommunicationFailurecurrentcommunication failure Controller A to Shelf SLOT 16
1.3.6.1.4.1.3607.2.20.0.1170NotificationgtccAToShelfSlot17DROP8CommunicationFailurecurrentcommunication failure Controller A to Shelf SLOT 17
1.3.6.1.4.1.3607.2.20.0.1180NotificationgtccAToDCCAProcessorCommunicationFailurecurrentcommunication failure ControllerP A to ControllerJ A processor
1.3.6.1.4.1.3607.2.20.0.1190NotificationgtccBToShelfSlot1DROP1CommunicationFailurecurrentcommunication failure Controller B to Shelf SLOT 1
1.3.6.1.4.1.3607.2.20.0.1200NotificationgtccBToShelfSlot2DROP2CommunicationFailurecurrentcommunication failure Controller B to Shelf SLOT 2
1.3.6.1.4.1.3607.2.20.0.1210NotificationgtccBToShelfSlot3DROP3CommunicationFailurecurrentcommunication failure Controller B to Shelf SLOT 3
1.3.6.1.4.1.3607.2.20.0.1220NotificationgtccBToShelfSlot4DROP4CommunicationFailurecurrentcommunication failure Controller B to Shelf SLOT 4
1.3.6.1.4.1.3607.2.20.0.1230NotificationgtccBToShelfSlot5TRUNK1CommunicationFailurecurrentcommunication failure Controller B to Shelf SLOT 5
1.3.6.1.4.1.3607.2.20.0.1240NotificationgtccBToShelfSlot6TRUNK2CommunicationFailurecurrentcommunication failure Controller B to Shelf SLOT 6
1.3.6.1.4.1.3607.2.20.0.1250NotificationgtccBToShelfSlot7TCCACommunicationFailurecurrentcommunication failure Controller B to Shelf SLOT 7
1.3.6.1.4.1.3607.2.20.0.1260NotificationgtccBToShelfSlot8XCONACommunicationFailurecurrentcommunication failure Controller B to Shelf SLOT 8
1.3.6.1.4.1.3607.2.20.0.1270NotificationgtccBToShelfSlot9AICCommunicationFailurecurrentcommunication failure Controller B to Shelf SLOT 9
1.3.6.1.4.1.3607.2.20.0.1280NotificationgtccBToShelfSlot10XCONBCommunicationFailurecurrentcommunication failure Controller B to Shelf SLOT 10
1.3.6.1.4.1.3607.2.20.0.1290NotificationgtccBToShelfSlot11TCCBCommunicationFailurecurrentcommunication failure Controller B to Shelf SLOT 11
1.3.6.1.4.1.3607.2.20.0.1300NotificationgtccBToShelfSlot12TRUNK3CommunicationFailurecurrentcommunication failure Controller B to Shelf SLOT 12
1.3.6.1.4.1.3607.2.20.0.1310NotificationgtccBToShelfSlot13TRUNK4CommunicationFailurecurrentcommunication failure Controller B to Shelf SLOT 13
1.3.6.1.4.1.3607.2.20.0.1320NotificationgtccBToShelfSlot14DROP5CommunicationFailurecurrentcommunication failure Controller B to Shelf SLOT 14
1.3.6.1.4.1.3607.2.20.0.1330NotificationgtccBToShelfSlot15DROP6CommunicationFailurecurrentcommunication failure Controller B to Shelf SLOT 15
1.3.6.1.4.1.3607.2.20.0.1340NotificationgtccBToShelfSlot16DROP7CommunicationFailurecurrentcommunication failure Controller B to Shelf SLOT 16
1.3.6.1.4.1.3607.2.20.0.1350NotificationgtccBToShelfSlot17DROP8CommunicationFailurecurrentcommunication failure Controller B to Shelf SLOT 17
1.3.6.1.4.1.3607.2.20.0.1360NotificationgtccBToDCCBProcessorCommunicationFailurecurrentcommunication failure ControllerP B to ControllerJ A processor
1.3.6.1.4.1.3607.2.20.0.1370NotificationgcontrolEquipmentControlCommunicationsEquipmentFailuredeprecatedcontrol Equipment Control Communications equipment failure
1.3.6.1.4.1.3607.2.20.0.1380NotificationgcontrolProcessorFailurecurrentcontrol Equipment Control processor failure
1.3.6.1.4.1.3607.2.20.0.1390NotificationgworkingMemoryFailurecurrentcontrol Equipment Working memory failure
1.3.6.1.4.1.3607.2.20.0.1400NotificationginterconnectionEquipmentFailurecurrentinterconnection Equipment failure
1.3.6.1.4.1.3607.2.20.0.1410NotificationgpayloadBusFailureToIOSlot1XCONSlot8currentinterconnection Equipment failure Payload Bus 1 Working
1.3.6.1.4.1.3607.2.20.0.1420NotificationgpayloadBusFailureToIOSlot2XCONSlot8currentinterconnection Equipment failure Payload Bus 2 Working
1.3.6.1.4.1.3607.2.20.0.1430NotificationgpayloadBusFailureToIOSlot3XCONSlot8currentinterconnection Equipment failure Payload Bus 3 Working
1.3.6.1.4.1.3607.2.20.0.1440NotificationgpayloadBusFailureToIOSlot4XCONSlot8currentinterconnection Equipment failure Payload Bus 4 Working
1.3.6.1.4.1.3607.2.20.0.1450NotificationgpayloadBusFailureToIOSlot5XCONSlot8currentinterconnection Equipment failure Payload Bus 5 Working
1.3.6.1.4.1.3607.2.20.0.1460NotificationgpayloadBusFailureToIOSlot6XCONSlot8currentinterconnection Equipment failure Payload Bus 6 Working
1.3.6.1.4.1.3607.2.20.0.1470NotificationgpayloadBusFailureToIOSlot12XCONSlot8currentinterconnection Equipment failure Payload Bus 7 Working
1.3.6.1.4.1.3607.2.20.0.1480NotificationgpayloadBusFailureToIOSlot13XCONSlot8currentinterconnection Equipment failure Payload Bus 8 Working
1.3.6.1.4.1.3607.2.20.0.1490NotificationgpayloadBusFailureToIOSlot14XCONSlot8currentinterconnection Equipment failure Payload Bus 9 Working
1.3.6.1.4.1.3607.2.20.0.1500NotificationgpayloadBusFailureToIOSlot15XCONSlot8currentinterconnection Equipment failure Payload Bus 10 Working
1.3.6.1.4.1.3607.2.20.0.1510NotificationgpayloadBusFailureToIOSlot16XCONSlot8currentinterconnection Equipment failure Payload Bus 11 Working
1.3.6.1.4.1.3607.2.20.0.1520NotificationgpayloadBusFailureToIOSlot17XCONSlot8currentinterconnection Equipment failure Payload Bus 12 Working
1.3.6.1.4.1.3607.2.20.0.1530NotificationgpayloadBusFailureToIOSlot1XCONSlot10currentinterconnection Equipment failure Payload Bus 1 Protect
1.3.6.1.4.1.3607.2.20.0.1540NotificationgpayloadBusFailureToIOSlot2XCONSlot10currentinterconnection Equipment failure Payload Bus 2 Protect
1.3.6.1.4.1.3607.2.20.0.1550NotificationgpayloadBusFailureToIOSlot3XCONSlot10currentinterconnection Equipment failure Payload Bus 3 Protect
1.3.6.1.4.1.3607.2.20.0.1560NotificationgpayloadBusFailureToIOSlot4XCONSlot10currentinterconnection Equipment failure Payload Bus 4 Protect
1.3.6.1.4.1.3607.2.20.0.1570NotificationgpayloadBusFailureToIOSlot5XCONSlot10currentinterconnection Equipment failure Payload Bus 5 Protect
1.3.6.1.4.1.3607.2.20.0.1580NotificationgpayloadBusFailureToIOSlot6XCONSlot10currentinterconnection Equipment failure Payload Bus 6 Protect
1.3.6.1.4.1.3607.2.20.0.1590NotificationgpayloadBusFailureToIOSlot12XCONSlot10currentinterconnection Equipment failure Payload Bus 7 Protect
1.3.6.1.4.1.3607.2.20.0.1600NotificationgpayloadBusFailureToIOSlot13XCONSlot10currentinterconnection Equipment failure Payload Bus 8 Protect
1.3.6.1.4.1.3607.2.20.0.1610NotificationgpayloadBusFailureToIOSlot14XCONSlot10currentinterconnection Equipment failure Payload Bus 9 Protect
1.3.6.1.4.1.3607.2.20.0.1620NotificationgpayloadBusFailureToIOSlot15XCONSlot10currentinterconnection Equipment failure Payload Bus 10 Protect
1.3.6.1.4.1.3607.2.20.0.1630NotificationgpayloadBusFailureToIOSlot16XCONSlot10currentinterconnection Equipment failure Payload Bus 11 Protect
1.3.6.1.4.1.3607.2.20.0.1640NotificationgpayloadBusFailureToIOSlot17XCONSlot10currentinterconnection Equipment failure Payload Bus 12 Protect
1.3.6.1.4.1.3607.2.20.0.1650NotificationgtimeSlotInterchangeEquipmentFailurecurrentinterconnection Eqpt Time slot interchange eqpt failure
1.3.6.1.4.1.3607.2.20.0.1660NotificationgequipmentFailurecurrentequipment failure
1.3.6.1.4.1.3607.2.20.0.1670NotificationghighTemperaturecurrentHigh Temperature
1.3.6.1.4.1.3607.2.20.0.1680NotificationginvalidMACAddresscurrentequipment failure Invalid MAC Address
1.3.6.1.4.1.3607.2.20.0.1690NotificationgboardFailurecurrentequipment failure Board Failure
1.3.6.1.4.1.3607.2.20.0.1700NotificationgdiagnosticFailurecurrentequipment failure Diagnostics Failure
1.3.6.1.4.1.3607.2.20.0.1710NotificationgmediumAccessControlFailurecurrentequipment failure Medium Access Control
1.3.6.1.4.1.3607.2.20.0.1720NotificationgfacilityTerminationEquipmentFailurecurrentfacility Termination equipment failure
1.3.6.1.4.1.3607.2.20.0.1730NotificationgautomaticLaserShutoffDueToHighTemperaturecurrentAutomatic Laser Shutoff Due To High Temperature
1.3.6.1.4.1.3607.2.20.0.1740NotificationgfailureToReleaseFromProtectioncurrentfailure To Release from protection
1.3.6.1.4.1.3607.2.20.0.1750NotificationgreceiverFailurecurrentfacility Termination equipment Receiver failure
1.3.6.1.4.1.3607.2.20.0.1760NotificationgtransmitFailurecurrentfacility Termination equipment Transmit failure
1.3.6.1.4.1.3607.2.20.0.1770NotificationgfacilityTerminationEquipmentReceiverMissingcurrentfacility Termination equipment Receiver missing
1.3.6.1.4.1.3607.2.20.0.1780NotificationgfacilityTerminationEquipmentTransmitterMissingcurrentfacility Termination equipment Transmitter missing
1.3.6.1.4.1.3607.2.20.0.1790NotificationgfailureToSwitchToProtectioncurrentfailure To Switch to protection
1.3.6.1.4.1.3607.2.20.0.1800NotificationgfailureToSwitchToProtectionRingcurrentfailure To Switch to protection Ring
1.3.6.1.4.1.3607.2.20.0.1810NotificationgfailureToSwitchToProtectionSpancurrentfailure To Switch to protection Span
1.3.6.1.4.1.3607.2.20.0.1820NotificationgfailureToSwitchToProtectionPathcurrentfailure to Switch to protection Path
1.3.6.1.4.1.3607.2.20.0.1830NotificationgfanFailurecurrentfailure of cooling fan tray
1.3.6.1.4.1.3607.2.20.0.1840NotificationgequipmentUnitPlugIncurrentequipment unit plug in
1.3.6.1.4.1.3607.2.20.0.1850NotificationgnePowerFailureAtConnectorcurrentNE Power Failure At Connector
1.3.6.1.4.1.3607.2.20.0.1860NotificationgfuseAlarmcurrentpower failure Fuse Alarm
1.3.6.1.4.1.3607.2.20.0.1870NotificationgsynchronizationUnitFailurecurrentsynchronization unit failure
1.3.6.1.4.1.3607.2.20.0.1880NotificationgsynchronizationSwitchingEquipmentFailurecurrentsynchronization switching Equipment failure
1.3.6.1.4.1.3607.2.20.0.1890NotificationgequipmentUnitUnpluggedcurrentequipment unit un plug
1.3.6.1.4.1.3607.2.20.0.1900Notificationgloopbackcurrentloop back
1.3.6.1.4.1.3607.2.20.0.1910Notificationgds1LoopbackDueToFEACCommandcurrentloopback due to FEAC command DS1
1.3.6.1.4.1.3607.2.20.0.1920NotificationgloopbackCommandSentToFarEndDS1currentloopback Command sent to Far End DS1
1.3.6.1.4.1.3607.2.20.0.1930Notificationgds3LoopbackDueToFEACCommandcurrentloopback due to FEAC command DS3
1.3.6.1.4.1.3607.2.20.0.1940Notificationgds3LoopbackCommandSentToFarEndcurrentloopback Command sent to Far End DS3
1.3.6.1.4.1.3607.2.20.0.1950Notificationgds2LoopbackDueToFarEndCommandcurrentloopback due to Far End Command DS2
1.3.6.1.4.1.3607.2.20.0.1960Notificationgds2LoopbackCommandSentToFarEndcurrentloopback Command sent to Far End DS2
1.3.6.1.4.1.3607.2.20.0.1970NotificationgfacilityLoopbackcurrentloop back facility
1.3.6.1.4.1.3607.2.20.0.1980NotificationgnetworkLoopbackcurrentloop back Network
1.3.6.1.4.1.3607.2.20.0.1990NotificationgterminalLoopbackcurrentloop back Terminal
1.3.6.1.4.1.3607.2.20.0.2000NotificationgmanuallyCausedAbnormalConditioncurrentmanually caused abnormal condition
1.3.6.1.4.1.3607.2.20.0.2010NotificationgethernetBridgeIsNewRootOfSpanningTreecurrentnew Root discovered in bridged network
1.3.6.1.4.1.3607.2.20.0.2020NotificationgethernetBridgeTopologyChangecurrenttopology change discovered in bridged network
1.3.6.1.4.1.3607.2.20.0.2030NotificationgnormalConditioncurrentnormal condition
1.3.6.1.4.1.3607.2.20.0.2040NotificationgembeddedOperationsChannelFailureLinkDowncurrentembedded Operations Channel failure link down
1.3.6.1.4.1.3607.2.20.0.2050NotificationgpeerStateMismatchcurrentpeer state mismatch
1.3.6.1.4.1.3607.2.20.0.2060NotificationgproceduralErrorcurrentprocedural Error
1.3.6.1.4.1.3607.2.20.0.2070NotificationgimproperRemovalcurrentImproper Removal
1.3.6.1.4.1.3607.2.20.0.2080NotificationgduplicateNodeIDcurrentDuplicate Node ID
1.3.6.1.4.1.3607.2.20.0.2090NotificationgblsrOutOfSynccurrentBLSR out of sync
1.3.6.1.4.1.3607.2.20.0.2100NotificationgblsrMultiNodeTableUpdateCompletedcurrentBLSR tables resynchronized
1.3.6.1.4.1.3607.2.20.0.2110NotificationgprotectionUnitNotAvailablecurrentprotection unit not available
1.3.6.1.4.1.3607.2.20.0.2120NotificationgperformanceMonitorThresholdCrossingAlertcurrentperformance Monitor Threshold Crossing Alert
1.3.6.1.4.1.3607.2.20.0.2130NotificationgprotectionSwitchcurrentoccurrence of a protection switching event
1.3.6.1.4.1.3607.2.20.0.2140NotificationgrecoveryOrServiceProtectionActionHasBeenInitiatedcurrentrecovery or service protection action has been initiated
1.3.6.1.4.1.3607.2.20.0.2150NotificationgautomaticSystemResetcurrentautomatic system Reset
1.3.6.1.4.1.3607.2.20.0.2160NotificationgautomaticUPSRSwitchCausedByAIScurrentautomatic UPSR switch caused by AIS
1.3.6.1.4.1.3607.2.20.0.2170NotificationgautomaticUPSRSwitchCausedByLOPcurrentautomatic UPSR switch caused by Lop
1.3.6.1.4.1.3607.2.20.0.2180NotificationgautomaticUPSRSwitchCausedByUNEQcurrentautomatic UPSR switch caused by Uneq
1.3.6.1.4.1.3607.2.20.0.2190NotificationgautomaticUPSRSwitchCausedByPDIcurrentautomatic UPSR switch caused by PDI
1.3.6.1.4.1.3607.2.20.0.2200NotificationgautomaticUPSRSwitchCausedBySFBERcurrentautomatic UPSR switch caused by Sfber
1.3.6.1.4.1.3607.2.20.0.2210NotificationgautomaticUPSRSwitchCausedBySDBERcurrentautomatic UPSR switch caused by Sdber
1.3.6.1.4.1.3607.2.20.0.2220NotificationgcoldRestartcurrentcold Restart
1.3.6.1.4.1.3607.2.20.0.2230NotificationgforcedSwitchBackToWorkingcurrentworking facility or eqpt forced switched to working
1.3.6.1.4.1.3607.2.20.0.2240NotificationgforcedSwitchBackToWorkingRingcurrentworking facility or eqpt forced switched to working Ring
1.3.6.1.4.1.3607.2.20.0.2250NotificationgforcedSwitchBackToWorkingSpancurrentworking facility or eqpt forced switched to working Span
1.3.6.1.4.1.3607.2.20.0.2260NotificationgforcedSwitchToProtectioncurrentworking facility or eqpt forced switched protection unit
1.3.6.1.4.1.3607.2.20.0.2270NotificationgforcedSwitchToProtectionRingcurrentworking facility or eqpt forced switched protection unit Ring
1.3.6.1.4.1.3607.2.20.0.2280NotificationgforcedSwitchToProtectionSpancurrentworking facility or eqpt forced switched protection unit Span
1.3.6.1.4.1.3607.2.20.0.2290NotificationgworkingFacilityOrEquipmentForcedToSwitchToProtectionPathcurrentworking facility or eqpt forced switched protection unit Path
1.3.6.1.4.1.3607.2.20.0.2300NotificationginitializationInitiatedcurrentinitialization initiated
1.3.6.1.4.1.3607.2.20.0.2310NotificationglockoutOfProtectioncurrentlockout of Protection
1.3.6.1.4.1.3607.2.20.0.2320NotificationglockoutOfProtectionRingcurrentlockout of Protection Ring
1.3.6.1.4.1.3607.2.20.0.2330NotificationglockoutOfProtectionSpancurrentlockout of Protection Span
1.3.6.1.4.1.3607.2.20.0.2340NotificationglockoutOfProtectionPathcurrentlockout of Protection Path
1.3.6.1.4.1.3607.2.20.0.2350NotificationglockoutOfWorkingcurrentlockout of working
1.3.6.1.4.1.3607.2.20.0.2360NotificationglockoutOfWorkingRingcurrentlockout of working Ring
1.3.6.1.4.1.3607.2.20.0.2370NotificationglockoutOfWorkingSpancurrentlockout of working Span
1.3.6.1.4.1.3607.2.20.0.2380NotificationgmanualSystemResetcurrentmanual system Reset
1.3.6.1.4.1.3607.2.20.0.2390NotificationgmanualSwitchToInternalClockcurrentmanual switch to internal clock
1.3.6.1.4.1.3607.2.20.0.2400NotificationgmanualSwitchToPrimaryReferencecurrentmanual Switch To Primary refernce
1.3.6.1.4.1.3607.2.20.0.2410NotificationgmanualSwitchToSecondReferencecurrentmanual Switch To Second reference
1.3.6.1.4.1.3607.2.20.0.2420NotificationgmanualSwitchToThirdReferencecurrentmanual Switch To Third refernce
1.3.6.1.4.1.3607.2.20.0.2430NotificationgmanualSwitchToFourthReferencecurrentmanual Switch To Fourth refernce
1.3.6.1.4.1.3607.2.20.0.2440NotificationgmanualSwitchToFifthReferencecurrentmanual Switch To Fifth refernce
1.3.6.1.4.1.3607.2.20.0.2450NotificationgmanualSwitchToSixthReferencecurrentmanual Switch To Sixth refernce
1.3.6.1.4.1.3607.2.20.0.2460NotificationgmanualSwitchBackToWorkingcurrentmanualSwitch of working facility or eqpt to protection Ring
1.3.6.1.4.1.3607.2.20.0.2470NotificationgmanualSwitchBackToWorkingRingcurrentmanualSwitch of working facility or eqpt to protection Span
1.3.6.1.4.1.3607.2.20.0.2480NotificationgmanualSwitchBackToWorkingSpancurrentmanualSwitch of working facility or eqpt to protection
1.3.6.1.4.1.3607.2.20.0.2490NotificationgmanualSwitchToProtectioncurrentmanualSwitch of Working facility or eqpt to Protection unit
1.3.6.1.4.1.3607.2.20.0.2500NotificationgmanualSwitchToProtectionRingcurrentworking facility or eqpt manualSwitch to Protection unit Ring
1.3.6.1.4.1.3607.2.20.0.2510NotificationgmanualSwitchToProtectionSpancurrentworking facility or eqpt manualSwitch to Protection unit Span
1.3.6.1.4.1.3607.2.20.0.2520NotificationgmanualSwitchOfWorkingFacilityOrEquipmentToProtectionPathcurrentmanualSwitch of working facility or eqpt to Protection Path
1.3.6.1.4.1.3607.2.20.0.2530NotificationgpowerfailRestartcurrentPowerfail Restart
1.3.6.1.4.1.3607.2.20.0.2540NotificationgringIsSquelchingTrafficcurrentring is squelching traffic
1.3.6.1.4.1.3607.2.20.0.2550NotificationgsoftwareDownloadInProgresscurrentsoftware download in progress
1.3.6.1.4.1.3607.2.20.0.2560NotificationgswitchToInternalClockcurrentSwitch To Internal clock
1.3.6.1.4.1.3607.2.20.0.2570NotificationgswitchToPrimaryReferencecurrentSwitch To Primary refernce
1.3.6.1.4.1.3607.2.20.0.2580NotificationgswitchToSecondReferencecurrentSwitch To Second refernce
1.3.6.1.4.1.3607.2.20.0.2590NotificationgswitchToThirdReferencecurrentSwitch To Third refernce
1.3.6.1.4.1.3607.2.20.0.2600NotificationgswitchToFourthReferencecurrentSwitch To Fourth refernce
1.3.6.1.4.1.3607.2.20.0.2610NotificationgswitchToFifthReferencecurrentSwitch To Fifth refernce
1.3.6.1.4.1.3607.2.20.0.2620NotificationgswitchToSixthReferencecurrentSwitch To Sixth refernce
1.3.6.1.4.1.3607.2.20.0.2630NotificationgsystemRebootcurrentsystem reboot
1.3.6.1.4.1.3607.2.20.0.2640NotificationgswitchedBackToWorkingcurrentSwitched Back To Working
1.3.6.1.4.1.3607.2.20.0.2650NotificationgswitchedToProtectioncurrentSwitched To Protection
1.3.6.1.4.1.3607.2.20.0.2660NotificationgwarmRestartcurrentwarm Restart
1.3.6.1.4.1.3607.2.20.0.2670NotificationgringIsInWaitToRestoreStatecurrentRing is in Wait To Restore state
1.3.6.1.4.1.3607.2.20.0.2680NotificationgmanualSwitchRequestcurrentManual Switch Request
1.3.6.1.4.1.3607.2.20.0.2690NotificationgforcedSwitchRequestcurrentForced Switch Request
1.3.6.1.4.1.3607.2.20.0.2700NotificationglockoutSwitchRequestcurrentLockout Switch Request
1.3.6.1.4.1.3607.2.20.0.2710NotificationgrmonHistoriesAndAlarmsResetRebootcurrentRMON histories and alarms have been reset due to chipset reboot
1.3.6.1.4.1.3607.2.20.0.2720NotificationgrmonThresholdCrossingAlarmcurrentCrossing of Falling/Rising Threshold detected
1.3.6.1.4.1.3607.2.20.0.2730NotificationgalarmsSuppressedByUserCommandcurrentAlarms Suppressed By User Command
1.3.6.1.4.1.3607.2.20.0.2740NotificationgalarmsSuppressedForMaintenancecurrentAlarms Suppressed For Maintenance
1.3.6.1.4.1.3607.2.20.0.2750NotificationgswitchingMatrixModuleFailurecurrentSwitching Matrix Module Failure
1.3.6.1.4.1.3607.2.20.0.2760NotificationglanConnectionPolarityReversedcurrentLan Connection Polarity Reversed
1.3.6.1.4.1.3607.2.20.0.2780NotificationgautonomousPMReportMessageInhibitedcurrentAutonomous Performance Monitoring Report Message Inhibited
1.3.6.1.4.1.3607.2.20.0.2790NotificationgioSlotToXCONCommunicationFailurecurrentIO Slot To XCON Communication Failure
1.3.6.1.4.1.3607.2.20.0.2800NotificationgstsPathTraceIdentifierMismatchcurrentSTS path trace identifier mismatch
1.3.6.1.4.1.3607.2.20.0.2810NotificationgnePowerFailureAtConnectorAcurrentNE power failure at connector A
1.3.6.1.4.1.3607.2.20.0.2820NotificationgnePowerFailureAtConnectorBcurrentNE power failure at connector B
1.3.6.1.4.1.3607.2.20.0.2830NotificationgfreeMemoryOnCardVeryLowcurrentFree memory on the card is very low
1.3.6.1.4.1.3607.2.20.0.2840NotificationgfreeMemoryOnCardNearZerocurrentFree memory on the card is near zero
1.3.6.1.4.1.3607.2.20.0.2850NotificationgexerciseRequestOnRingcurrentExercise Ring.
1.3.6.1.4.1.3607.2.20.0.2860NotificationgexerciseRequestOnSpancurrentExercise Span.
1.3.6.1.4.1.3607.2.20.0.2870NotificationgsquelchingPathcurrentSquelching Path:
1.3.6.1.4.1.3607.2.20.0.2880NotificationgextraTrafficPreemptedcurrentExtra Traffic Preempted.
1.3.6.1.4.1.3607.2.20.0.2890NotificationgfarEndLockoutOfWorkingRingcurrentFar End Lockout of working - Ring.
1.3.6.1.4.1.3607.2.20.0.2900NotificationgfarEndLockoutOfWorkingSpancurrentFar End Lockout of working - Span.
1.3.6.1.4.1.3607.2.20.0.2910NotificationgfarEndLockoutOfProtectionRingcurrentFar End Lockout of Protection - Ring.
1.3.6.1.4.1.3607.2.20.0.2920NotificationgfarEndLockoutOfProtectionAllSpanscurrentFar End Lockout of Protection - All Spans.
1.3.6.1.4.1.3607.2.20.0.2930NotificationgfarEndWorkingFacilityForcedToSwitchToProtectionRingcurrentFar End Working facility forced to switch to protection unit - Ring.
1.3.6.1.4.1.3607.2.20.0.2940NotificationgfarEndWorkingFacilityForcedToSwitchToProtectionSpancurrentFar End Working facility forced to switch to protection unit - Span.
1.3.6.1.4.1.3607.2.20.0.2950NotificationgfarEndManualSwitchOfWorkingFacilityToProtectionRingcurrentFar End Manual Switch of Working facility to Protection unit - Ring.
1.3.6.1.4.1.3607.2.20.0.2960NotificationgfarEndManualSwitchOfWorkingFacilityToProtectionSpancurrentFar End Manual Switch of Working facility to Protection unit - Span.
1.3.6.1.4.1.3607.2.20.0.2970NotificationgfarEndExercisingRingcurrentFar End Exercise Ring.
1.3.6.1.4.1.3607.2.20.0.2980NotificationgfarEndExercisingSpancurrentFar End Exercise Span.
1.3.6.1.4.1.3607.2.20.0.2990NotificationgfarEndBERThresholdPassedForSignalFailureRingcurrentFar End BER threshold passed for Signal Failure - Ring.
1.3.6.1.4.1.3607.2.20.0.3000NotificationgfarEndBERThresholdPassedForSignalFailureSpancurrentFar End BER threshold passed for Signal Failure - Span.
1.3.6.1.4.1.3607.2.20.0.3010NotificationgfarEndBERThresholdPassedForSignalDegradeRingcurrentFar End BER threshold passed for Signal Degrade - Ring.
1.3.6.1.4.1.3607.2.20.0.3020NotificationgfarEndBERThresholdPassedForSignalDegradeSpancurrentFar End BER threshold passed for Signal Degrade - Span.
1.3.6.1.4.1.3607.2.20.0.3030NotificationgapsChannelFarEndProtectionLineSignalDegradecurrentAPS Channel - Far End Protection Line Signal Degrade.
1.3.6.1.4.1.3607.2.20.0.3040NotificationgringSwitchIsActiveOnTheEastSidecurrentRing Switch is active on the East Side.
1.3.6.1.4.1.3607.2.20.0.3050NotificationgringSwitchIsActiveOnTheWestSidecurrentRing Switch is active on the West Side.
1.3.6.1.4.1.3607.2.20.0.3060NotificationgspanSwitchIsActiveOnTheEastSidecurrentSpan Switch is active on the East Side.
1.3.6.1.4.1.3607.2.20.0.3070NotificationgspanSwitchIsActiveOnTheWestSidecurrentSpan Switch is active on the West Side.
1.3.6.1.4.1.3607.2.20.0.3080NotificationguniDirectionalFullPassThroughIsActivecurrentUni-directional Full Pass Through is active.
1.3.6.1.4.1.3607.2.20.0.3090NotificationgbiDirectionalFullPassThroughIsActivecurrentBi-directional Full Pass Through is active.
1.3.6.1.4.1.3607.2.20.0.3100NotificationgkBytesPassThroughIsActivecurrentK Bytes Pass Through is active.
1.3.6.1.4.1.3607.2.20.0.3110NotificationgringIsSegmentedcurrentRing is Segmented.
1.3.6.1.4.1.3607.2.20.0.3120NotificationgringTopologyIsUnderConstructioncurrentRing Topology is under construction.
1.3.6.1.4.1.3607.2.20.0.3130NotificationglockoutOfProtectionAllSpanscurrentLockout of Protection - All Spans.
1.3.6.1.4.1.3607.2.20.0.3140NotificationgfarEndOfFiberIsProvisionedWithDifferentRingIDcurrentFar end of fiber is provisioned with different ring ID
1.3.6.1.4.1.3607.2.20.0.3150NotificationgbothEndsOfFiberProvisionedAsEastOrBothAsWestcurrentBoth ends of fiber provisioned as East, or both as West
1.3.6.1.4.1.3607.2.20.0.3160NotificationgsecurityInvalidLoginUsernameSeeAuditTraildeprecatedSecurity: Invalid Login Username - See Audit Trail
1.3.6.1.4.1.3607.2.20.0.3170NotificationgautonomousMessagesInhibitedcurrentAutonomous messages inhibited
1.3.6.1.4.1.3607.2.20.0.3180NotificationgtrafficStormOnLANLANTemporarilyDisabledcurrentTraffic storm on LAN. LAN temporarily disabled.
1.3.6.1.4.1.3607.2.20.0.3190NotificationgreptdbchgMessagesInhibitedcurrentREPT^DBCHG messages of TL1 inhibited
1.3.6.1.4.1.3607.2.20.0.3200NotificationgsecurityUserIDHasExpiredcurrentSecurity: user ID has expired
1.3.6.1.4.1.3607.2.20.0.3210NotificationgpartialFanFailurecurrentPartial Fan Failure
1.3.6.1.4.1.3607.2.20.0.3220NotificationgforcedSwitchRequestOnRingcurrentForce switch request on Ring
1.3.6.1.4.1.3607.2.20.0.3230NotificationgforcedSwitchRequestOnSpancurrentForce switch request on Span
1.3.6.1.4.1.3607.2.20.0.3240NotificationglockoutSwitchRequestOnRingcurrentLockout switch request on Ring
1.3.6.1.4.1.3607.2.20.0.3250NotificationglockoutSwitchRequestOnSpancurrentLockout switch request on Span
1.3.6.1.4.1.3607.2.20.0.3260NotificationgmanualSwitchRequestOnRingcurrentManual switch request on Ring
1.3.6.1.4.1.3607.2.20.0.3270NotificationgmanualSwitchRequestOnSpancurrentManual switch request on Span
1.3.6.1.4.1.3607.2.20.0.3280NotificationgcommunicationFailurePeerToPeerSlotControlBusAcurrentPeer to Peer Slot communication failure - Control Bus A
1.3.6.1.4.1.3607.2.20.0.3290NotificationgcommunicationFailurePeerToPeerSlotControlBusBcurrentPeer to Peer Slot communication failure - Control Bus B
1.3.6.1.4.1.3607.2.20.0.3300NotificationgcontrollerAToShelfSlotCommunicationFailurecurrentController A to shelf slot communication failure
1.3.6.1.4.1.3607.2.20.0.3310NotificationgcontrollerBToShelfSlotCommunicationFailurecurrentController B to shelf slot communication failure
1.3.6.1.4.1.3607.2.20.0.3320NotificationginterconnectionEquipmentFailureWorkingPayloadBuscurrentInterconnection Equipment Failure - Working Payload Bus
1.3.6.1.4.1.3607.2.20.0.3330NotificationginterconnectionEquipmentFailureProtectPayloadBuscurrentInterconnection Equipment Failure - Protect Payload Bus
1.3.6.1.4.1.3607.2.20.0.3340NotificationginhibitSwitchToProtectRequestOnEquipmentcurrentInhibit Switch to Protect Request on equipment
1.3.6.1.4.1.3607.2.20.0.3350NotificationginhibitSwitchToWorkingRequestOnEquipmentcurrentInhibit Switch to Working Request on equipment
1.3.6.1.4.1.3607.2.20.0.3360NotificationgberThresholdExceededForSignalDegradeLinecurrentBER Threshold exceeded for Signal Degrade - Line
1.3.6.1.4.1.3607.2.20.0.3370NotificationgberThresholdExceededForSignalDegradePathcurrentBER Threshold exceeded for Signal Degrade - Path
1.3.6.1.4.1.3607.2.20.0.3380NotificationgberThresholdExceededForSignalFailureLinecurrentBER Threshold Exceeded For Signal Failure - Line
1.3.6.1.4.1.3607.2.20.0.3390NotificationgberThresholdExceededForSignalFailurePathcurrentBER Threshold Exceeded For Signal Failure - Path
1.3.6.1.4.1.3607.2.20.0.3400NotificationgexercisingRingSuccessfullycurrentExercising Ring Successfully
1.3.6.1.4.1.3607.2.20.0.3410NotificationgexercisingSpanSuccessfullycurrentExercising Span Successfully
1.3.6.1.4.1.3607.2.20.0.3420NotificationgspanIsInWaitToRestoreStatecurrentSpan is in Wait To Restore state
1.3.6.1.4.1.3607.2.20.0.3430NotificationgexerciseRequestOnRingFailedcurrentExercise Ring Failed
1.3.6.1.4.1.3607.2.20.0.3440NotificationgexerciseRequestOnSpanFailedcurrentExercise Span Failed
1.3.6.1.4.1.3607.2.20.0.3450NotificationgfarEndLockoutOfProtectionSpancurrentFar end Lockout of Protection Channel - Span
1.3.6.1.4.1.3607.2.20.0.3460NotificationgmanufacturingDataMemoryEEPROMFailurecurrentManufacturing EEPROM Failure
1.3.6.1.4.1.3607.2.20.0.3470NotificationgreplaceableEquipmentOrUnitIsMissingcurrentReplaceable Equipment/Unit Is Missing
1.3.6.1.4.1.3607.2.20.0.3480NotificationgsoftwareDownloadFailedcurrentSoftware Download Failed
1.3.6.1.4.1.3607.2.20.0.3490NotificationgextraTrafficPCADroppedcurrentExtra Traffic Dropped
1.3.6.1.4.1.3607.2.20.0.3500NotificationgetherTxOversubscribedcurrentpkt loss due to oversubscribed xmit
1.3.6.1.4.1.3607.2.20.0.3510NotificationgetherRxOverSubscribedcurrentpkt loss due to oversubscribed rcv
1.3.6.1.4.1.3607.2.20.0.3520NotificationgetherTxExcessFlowCtrlcurrentexcessive ethernet flow ctl xmited
1.3.6.1.4.1.3607.2.20.0.3530NotificationgetherRxExcessFlowCtrlcurrentexcessive ethernet flow ctl recvd
1.3.6.1.4.1.3607.2.20.0.3540NotificationgtransportLayerFailurecurrenttransport layer failure
1.3.6.1.4.1.3607.2.20.0.3550NotificationgetherTxUnderruncurrentEther hdge internal fifo underrun
1.3.6.1.4.1.3607.2.20.0.3560NotificationgsynchronizationReferenceFrequencyOutOfBoundscurrentSynchronization reference frequency out of bounds.
1.3.6.1.4.1.3607.2.20.0.3570NotificationgntpOrSntpHostFailurecurrentNTP/SNTP Host Failure.
1.3.6.1.4.1.3607.2.20.0.3580NotificationgpeerCardNotRespondingcurrentPeer Card Not Responding
1.3.6.1.4.1.3607.2.20.0.3590NotificationgalarmsAndEventsSuppressedForThisObjectcurrentAlarms and events suppressed for this object
1.3.6.1.4.1.3607.2.20.0.3600Notificationgds3FrameFormatMismatchcurrentDS3 Frame Format Mismatch
1.3.6.1.4.1.3607.2.20.0.3610NotificationgwaitToRestorecurrentWait To Restore
1.3.6.1.4.1.3607.2.20.0.3620NotificationgextremeHighVoltBatteryAcurrentExtreme High Volt Battery A
1.3.6.1.4.1.3607.2.20.0.3630NotificationgextremeLowVoltBatteryAcurrentExtreme Low Volt Battery A
1.3.6.1.4.1.3607.2.20.0.3640NotificationgextremeHighVoltBatteryBcurrentExtreme High Volt Battery B
1.3.6.1.4.1.3607.2.20.0.3650NotificationgextremeLowVoltBatteryBcurrentExtreme Low Volt Battery B
1.3.6.1.4.1.3607.2.20.0.3660NotificationgiosConfigCopyFailedcurrentIOS config copy failed
1.3.6.1.4.1.3607.2.20.0.3670NotificationgiosConfigCopyInProgresscurrentIOS config copy in progress
1.3.6.1.4.1.3607.2.20.0.3680NotificationgiosConfigCopySuccesscurrentIOS Config Copy Success
1.3.6.1.4.1.3607.2.20.0.3710NotificationgsignalingUnableToSetupCircuitcurrentSignaling Unable to setup circuit
1.3.6.1.4.1.3607.2.20.0.3712NotificationgerrorInStartupConfigcurrentError in Startup Config
1.3.6.1.4.1.3607.2.20.0.3714NotificationgnoStartupConfigcurrentNo Startup Config
1.3.6.1.4.1.3607.2.20.0.3716NotificationgneedToSaveRunningConfigcurrentNeed to Save Running Config
1.3.6.1.4.1.3607.2.20.0.3718NotificationginvalidAlarmcurrentInvalid Alarm
1.3.6.1.4.1.3607.2.20.0.3720NotificationgrsvpHelloFSMToNeighborDowncurrentRSVP Hello FSM to Neighbor down
1.3.6.1.4.1.3607.2.20.0.3722NotificationgsecurityInvalidLoginUsernamecurrentSecurity: Invalid Login - Username - See Audit Log
1.3.6.1.4.1.3607.2.20.0.3724NotificationgdatabaseBackupFailedcurrentDatabase Backup Failed
1.3.6.1.4.1.3607.2.20.0.3726NotificationgdatabaseRestoreFailedcurrentDatabase Restore Failed
1.3.6.1.4.1.3607.2.20.0.3730NotificationglmpHelloFSMToControlChannelDowncurrentLMP Hello FSM to Control Channel down
1.3.6.1.4.1.3607.2.20.0.3740NotificationglmpNeighborDiscoveryHasFailedcurrentLMP Neighbor Discovery has failed
1.3.6.1.4.1.3607.2.20.0.3750NotificationgunauthorizedIncomingSignalingRequestcurrentUnauthorized incoming signaling request
1.3.6.1.4.1.3607.2.20.0.3760NotificationgauditLog80PercentFullcurrentAudit Log 80 Percent Full
1.3.6.1.4.1.3607.2.20.0.3762NotificationgmoduleCommunicationFailurecurrentModule Communication Failure
1.3.6.1.4.1.3607.2.20.0.3764NotificationgauditLog100PercentFullOldestRecordsWillBeLostcurrentAudit Log 100 Percent Full - Oldest records will be lost
1.3.6.1.4.1.3607.2.20.0.3766NotificationgstandbyDatabaseOutOfSynccurrentStandby Database Out of Sync
1.3.6.1.4.1.3607.2.20.0.3768NotificationgredundantPowerCapabilityLostcurrentRedundant Power Capability Lost
1.3.6.1.4.1.3607.2.20.0.3770NotificationgforcedSwitchToPrimaryReferencecurrentForced Switch To Primary Reference
1.3.6.1.4.1.3607.2.20.0.3780NotificationgforcedSwitchToSecondReferencecurrentForced Switch To Second Reference
1.3.6.1.4.1.3607.2.20.0.3790NotificationgforcedSwitchToThirdReferencecurrentForced Switch To Third Reference
1.3.6.1.4.1.3607.2.20.0.3800NotificationgforcedSwitchToInternalClockcurrentForced Switch To Internal Clock
1.3.6.1.4.1.3607.2.20.0.3805NotificationgindustrialHighTemperaturecurrentIndustrial High Temperature
1.3.6.1.4.1.3607.2.20.0.3810NotificationgimproperMatrixEquipmentInsertedcurrentImproper matrix equipment inserted
1.3.6.1.4.1.3607.2.20.0.3820NotificationgeqptProblemOnCarrierOrPIMcurrentEQPT problem on Carrier or PIM
1.3.6.1.4.1.3607.2.20.0.3830NotificationgeqptProblemOnPIMOrPPMcurrentEQPT problem on PIM or PPM
1.3.6.1.4.1.3607.2.20.0.4000NotificationgtimSectionTraceIdentifierMismatchFailurecurrentTIM Section - Trace Identifier Mismatch Failure.
1.3.6.1.4.1.3607.2.20.0.4010NotificationgaisMultiplexSectionAlarmIndicationSignalcurrentSDH Multiplex Section - Alarm Indication Signal.
1.3.6.1.4.1.3607.2.20.0.4020NotificationgrdiMultiplexSectionRemoteDefectOrAlarmIndicationcurrentSDH Multiplex Section - Remote Defect Indication.
1.3.6.1.4.1.3607.2.20.0.4030NotificationgtimHighOrderTraceIdentifierMismatchFailurecurrentSDH High Order - Trace Identifier Mismatch.
1.3.6.1.4.1.3607.2.20.0.4040NotificationgaisAdministrationUnitAlarmIndicationSignalcurrentSDH Administration Unit - Alarm Indication Signal.
1.3.6.1.4.1.3607.2.20.0.4050NotificationglopAdministrationUnitLossOfPointercurrentSDH Administration Unit - Loss of Pointer.
1.3.6.1.4.1.3607.2.20.0.4060NotificationgslmfUnequippedHighOrderPathUnequippedcurrentSDH SLMF High Order - Unequipped Path.
1.3.6.1.4.1.3607.2.20.0.4070NotificationgslmfPLMHighOrderPathLabelMismatchcurrentSDH SLMF High Order - Path Label Mismatch.
1.3.6.1.4.1.3607.2.20.0.4080NotificationgrdiHighOrderRemoteDefectOrAlarmIndicationcurrentSDH High Order - Remote Defect Indication.
1.3.6.1.4.1.3607.2.20.0.4090NotificationglopTributaryUnitLossOfPointercurrentSDH Tributary Unit - Loss of Pointer.
1.3.6.1.4.1.3607.2.20.0.4100NotificationgaisTributaryUnitAlarmIndicationSignalcurrentSDH Tributary Unit - Alarm Indication Signal.
1.3.6.1.4.1.3607.2.20.0.4110NotificationgslmfUnequippedLowOrderPathUnequippedcurrentSDH Low Order - SLMF Unequipped Path.
1.3.6.1.4.1.3607.2.20.0.4120NotificationgslmfPLMLowOrderPathLabelMismatchcurrentSDH Low Order - SLMF Path Label Mismatch.
1.3.6.1.4.1.3607.2.20.0.4130NotificationgtimLowOrderTraceIdentifierMismatchFailurecurrentSDH Low Order - Trace Identifier Mismatch.
1.3.6.1.4.1.3607.2.20.0.4140NotificationgrfiLowOrderRemoteFailureOrAlarmIndicationcurrentSDH Low Order - Remote Failure Indication.
1.3.6.1.4.1.3607.2.20.0.4150Notificationgg811PrimaryReferenceClockTraceablecurrentG811 - Primary Reference Clock traceable.
1.3.6.1.4.1.3607.2.20.0.4160Notificationgg812TransitNodeClockTraceablecurrentG812 - Transit Node Clock traceable.
1.3.6.1.4.1.3607.2.20.0.4170Notificationgg812LocalNodeClockTraceablecurrentG812 - Local Node Clock traceable.
1.3.6.1.4.1.3607.2.20.0.4180Notificationgg813SynchronousEquipmentTimingSourceTraceablecurrentG813 - Synchronous Equipment Timing Source traceable.
1.3.6.1.4.1.3607.2.20.0.4190Notificationge1LoopbackDueToFEACCommandcurrentloopback due to FEAC Command E1
1.3.6.1.4.1.3607.2.20.0.4200Notificationge1LoopbackCommandSentToFarEndcurrentloopback Command sent to Far End E1
1.3.6.1.4.1.3607.2.20.0.4210Notificationge3LoopbackDueToFEACCommandcurrentloopback due to FEAC Command E3
1.3.6.1.4.1.3607.2.20.0.4220NotificationgfarEndMultipleE1LOSDetectedOnE3currentfar end Multiple E1 LOS detected on E3
1.3.6.1.4.1.3607.2.20.0.4230NotificationgfarEndE1EqptFailNonServiceAffectingcurrentfar end E1 eqpt fail non service affecting
1.3.6.1.4.1.3607.2.20.0.4240NotificationgfarEndE1EqptFailServiceAffectingcurrentfar end E1 eqpt fail service affecting
1.3.6.1.4.1.3607.2.20.0.4250NotificationgfarEndSingleE1LOScurrentfar end Single E1 LOS
1.3.6.1.4.1.3607.2.20.0.4260NotificationgfarEndE3EqptFailServiceAffectingcurrentfar end E3 eqpt fail service affecting
1.3.6.1.4.1.3607.2.20.0.4270Notificationge3LoopbackCommandSentToFarEndcurrentloopback Command sent to Far End E3
1.3.6.1.4.1.3607.2.20.0.4280NotificationgfarEndE3EqptFailNonServiceAffectingcurrentfar end E3 eqpt fail non service affecting
1.3.6.1.4.1.3607.2.20.0.4290NotificationglowVoltBatteryAcurrentLow Volt - Battery A
1.3.6.1.4.1.3607.2.20.0.4300NotificationghighVoltBatteryAcurrentHigh Volt - Battery A
1.3.6.1.4.1.3607.2.20.0.4310NotificationglowVoltBatteryBcurrentLow Volt - Battery B
1.3.6.1.4.1.3607.2.20.0.4320NotificationghighVoltBatteryBcurrentHigh Volt - Battery B
1.3.6.1.4.1.3607.2.20.0.4330NotificationgmsspRingOutOfSynccurrentMS-SP ring out of sync
1.3.6.1.4.1.3607.2.20.0.4340NotificationgmsspMultiNodeTableUpdateCompletedcurrentMS-SP ring tables resynchronized
1.3.6.1.4.1.3607.2.20.0.4350NotificationgautomaticSNCPSwitchCausedByAIScurrentautomatic SNCP switch caused by AIS
1.3.6.1.4.1.3607.2.20.0.4360NotificationgautomaticSNCPSwitchCausedByLOPcurrentautomatic SNCP switch caused by Lop
1.3.6.1.4.1.3607.2.20.0.4370NotificationgautomaticSNCPSwitchCausedByUNEQcurrentautomatic SNCP switch caused by Uneq
1.3.6.1.4.1.3607.2.20.0.4380NotificationgautomaticSNCPSwitchCausedByPDIcurrentautomatic SNCP switch caused by PDI
1.3.6.1.4.1.3607.2.20.0.4390NotificationgautomaticSNCPSwitchCausedBySFBERcurrentautomatic SNCP switch caused by Sfber
1.3.6.1.4.1.3607.2.20.0.4400NotificationgautomaticSNCPSwitchCausedBySDBERcurrentautomatic SNCP switch caused by Sdber
1.3.6.1.4.1.3607.2.20.0.4410NotificationgstmConcatenationErrorcurrentconcatenation error STM
1.3.6.1.4.1.3607.2.20.0.4420Notificationge3IdleConditioncurrentidle Condition E3
1.3.6.1.4.1.3607.2.20.0.4430NotificationgchannelMSSPInconsistentAPSCodecurrentchannel MSSP inconsistent APS code
1.3.6.1.4.1.3607.2.20.0.4440NotificationgchannelMSSPImproperAPSCodeAPScurrentchannel MSSP Improper APS code APS
1.3.6.1.4.1.3607.2.20.0.4450NotificationgchannelMSSPNodeIdMismatchAPScurrentchannel MSSP Node Id Mismatch APS
1.3.6.1.4.1.3607.2.20.0.4460NotificationgchannelMSSPDefaultKAPScurrentchannel MSSP Default K APS
1.3.6.1.4.1.3607.2.20.0.4470NotificationgchannelMSSPConnectionLossAPScurrentchannel MSSP Connection loss APS
1.3.6.1.4.1.3607.2.20.0.4480NotificationgminimumClockTraceableSDHcurrentSDH Minimum clock Traceable
1.3.6.1.4.1.3607.2.20.0.4490NotificationglineIsInWaitToRestoreStateSDHcurrentSDH line is in Wait To Restore state
1.3.6.1.4.1.3607.2.20.0.4500NotificationgberThresholdExceededForSignalDegradeHighOrdercurrentBER Threshold exceeded for Signal Degrade - High Order
1.3.6.1.4.1.3607.2.20.0.4510NotificationgberThresholdExceededForSignalFailureHighOrdercurrentBER Threshold exceeded for Signal Failure - High Order
1.3.6.1.4.1.3607.2.20.0.4520NotificationgberThresholdExceededForSignalDegradeLowOrdercurrentBER Threshold exceeded for Signal Degrade - Low Order
1.3.6.1.4.1.3607.2.20.0.4530NotificationgberThresholdExceededForSignalFailureLowOrdercurrentBER Threshold exceeded for Signal Failure - Low Order
1.3.6.1.4.1.3607.2.20.0.4540NotificationgfailureToSwitchToProtectionHighOrderPathcurrentFailure To Switch To Protection - High Order Path
1.3.6.1.4.1.3607.2.20.0.4550NotificationgfailureToSwitchToProtectionLowOrderPathcurrentFailure To Switch To Protection - Low Order Path
1.3.6.1.4.1.3607.2.20.0.4560NotificationglofAdministrationUnitLossOfMultiFramecurrentSDH Administration Unit Loss of Multiframe.
1.3.6.1.4.1.3607.2.20.0.4570NotificationgsdhSpanIsInWaitToRestoreStatecurrentSDH span is in Wait To Restore state
1.3.6.1.4.1.3607.2.20.0.4755Notificationga8b10bOutOfSynccurrent8B10B Out of Sync
1.3.6.1.4.1.3607.2.20.0.4760NotificationgodukPMAlarmIndicationSignalcurrentODUk: Alarm Indication Signal
1.3.6.1.4.1.3607.2.20.0.4765NotificationgotukAlarmIndicationSignalcurrentOTUk: Alarm Indication Signal
1.3.6.1.4.1.3607.2.20.0.4770NotificationgotukSMBackwardDefectIndicationcurrentOTUk: Backward Defect Indication
1.3.6.1.4.1.3607.2.20.0.4780NotificationgfecUncorrectedWordcurrentFEC Uncorrected Word
1.3.6.1.4.1.3607.2.20.0.4785NotificationggccTerminationFailurecurrentGCC Termination Failure
1.3.6.1.4.1.3607.2.20.0.4790NotificationgotukIncomingAlignmentErrorcurrentOTUk: Incoming Alignment Error
1.3.6.1.4.1.3607.2.20.0.4795NotificationgodukLockedDefectPMcurrentODUk: Locked Defect PM
1.3.6.1.4.1.3607.2.20.0.4800NotificationglossOfMultiFramecurrentLoss of Multi-Frame
1.3.6.1.4.1.3607.2.20.0.4805NotificationgodukOpenConnectionIndicationcurrentODUk: Open Connection Indication
1.3.6.1.4.1.3607.2.20.0.4810NotificationgpayloadTypeIdentifierMismatchcurrentPayload Type Identifier Mismatch
1.3.6.1.4.1.3607.2.20.0.4815NotificationgodukTrailTraceIdentifierMismatchcurrentODUk: Trail Trace Identifier Mismatch
1.3.6.1.4.1.3607.2.20.0.4820NotificationgotukTrailTraceIdentifierMismatchcurrentOTUk: Trail Trace Identifier Mismatch
1.3.6.1.4.1.3607.2.20.0.4825NotificationgequipmentHighLaserBiascurrentEquipment High Laser Bias
1.3.6.1.4.1.3607.2.20.0.4830NotificationgequipmentHighLaserTempcurrentEquipment High Laser Temp
1.3.6.1.4.1.3607.2.20.0.4835NotificationgequipmentHighLaserPeltiercurrentEquipment High Laser Peltier
1.3.6.1.4.1.3607.2.20.0.4840NotificationgfacilityHighRxPowercurrentFacility High Rx power
1.3.6.1.4.1.3607.2.20.0.4845NotificationgequipmentHighTxPowercurrentEquipment High Tx power
1.3.6.1.4.1.3607.2.20.0.4850NotificationgequipmentHighTransceiverVoltagecurrentEquipment High Transceiver voltage
1.3.6.1.4.1.3607.2.20.0.4855NotificationgequipmentLowLaserBiascurrentEquipment Low Laser Bias
1.3.6.1.4.1.3607.2.20.0.4860NotificationgequipmentLowLaserTempcurrentEquipment Low Laser Temp
1.3.6.1.4.1.3607.2.20.0.4865NotificationgequipmentLowLaserPeltiercurrentEquipment Low Laser Peltier
1.3.6.1.4.1.3607.2.20.0.4870NotificationgfacilityLowRxPowercurrentFacility Low Rx power
1.3.6.1.4.1.3607.2.20.0.4875NotificationgequipmentLowTxPowercurrentEquipment Low Tx power
1.3.6.1.4.1.3607.2.20.0.4880NotificationgequipmentLowTransceiverVoltagecurrentEquipment Low Transceiver voltage
1.3.6.1.4.1.3607.2.20.0.4885NotificationgequipmentRxLockedcurrentEquipment Rx Locked
1.3.6.1.4.1.3607.2.20.0.4890NotificationgequipmentSquelchedcurrentEquipment Squelched
1.3.6.1.4.1.3607.2.20.0.4895NotificationgequipmentTxLockedcurrentEquipment Tx Locked
1.3.6.1.4.1.3607.2.20.0.4900NotificationgotukSignalFailurecurrentOTUK Signal Failure
1.3.6.1.4.1.3607.2.20.0.4905NotificationgodukSignalFailurecurrentODUK Signal Failure
1.3.6.1.4.1.3607.2.20.0.4910NotificationgotukSignalDegradecurrentOTUK Signal Degrade
1.3.6.1.4.1.3607.2.20.0.4915NotificationgodukSignalDegradecurrentODUK Signal Degrade
1.3.6.1.4.1.3607.2.20.0.4920NotificationgpluggablePortMissingcurrentPluggable Port missing
1.3.6.1.4.1.3607.2.20.0.4925NotificationgpluggablePortRateMismatchcurrentPluggable Port rate mismatch
1.3.6.1.4.1.3607.2.20.0.4930NotificationgpluggablePortSecurityCodeMismatchcurrentPluggable Port security code mismatch
1.3.6.1.4.1.3607.2.20.0.4935NotificationgtciNotSelectedcurrentTci not selected
1.3.6.1.4.1.3607.2.20.0.4940Notificationgtci1ClockFailurecurrentTci 1 Clock Failure
1.3.6.1.4.1.3607.2.20.0.4945NotificationgodukPMBackwardDefectIndicationcurrentODUk: PM Backward Defect Indication
1.3.6.1.4.1.3607.2.20.0.4950NotificationgodukTCM1BackwardDefectIndicationcurrentODUk: TCM1 Backward Defect Indication
1.3.6.1.4.1.3607.2.20.0.4955NotificationgodukTCM2BackwardDefectIndicationcurrentODUk: TCM2 Backward Defect Indication
1.3.6.1.4.1.3607.2.20.0.4960NotificationgequipmentHighRxTemperaturecurrentEquipment High Rx temperature
1.3.6.1.4.1.3607.2.20.0.4965NotificationgequipmentLowRxTemperaturecurrentEquipment Low Rx temperature
1.3.6.1.4.1.3607.2.20.0.4970Notificationgtci2ClockFailurecurrentTci 2 Clock Failure
1.3.6.1.4.1.3607.2.20.0.4975NotificationgequipmentWavelengthMismatchcurrentEquipment Wavelength Mismatch
1.3.6.1.4.1.3607.2.20.0.4980NotificationgdspCommunicationFailurecurrentDSP Communication Failure
1.3.6.1.4.1.3607.2.20.0.4985NotificationgdspFailurecurrentDSP Failure
1.3.6.1.4.1.3607.2.20.0.5000NotificationglaserApproachingEndOfLifecurrentLaser Approaching End of Life
1.3.6.1.4.1.3607.2.20.0.5010NotificationgcrossconnectLoopbackcurrentCross-connect Loopback
1.3.6.1.4.1.3607.2.20.0.5020NotificationgadminLogoutOfUsercurrentAdmin Logout of User
1.3.6.1.4.1.3607.2.20.0.5030NotificationguserLockedOutcurrentUser Locked Out
1.3.6.1.4.1.3607.2.20.0.5040NotificationgadminLockoutOfUsercurrentAdmin Lockout of User
1.3.6.1.4.1.3607.2.20.0.5050NotificationgadminLockoutClearcurrentAdmin Lockout Clear
1.3.6.1.4.1.3607.2.20.0.5060NotificationginvalidLoginUsernamecurrentInvalid Login: Username
1.3.6.1.4.1.3607.2.20.0.5070NotificationgsecurityInvalidLoginPasswordcurrentInvalid Login: Password
1.3.6.1.4.1.3607.2.20.0.5080NotificationgsecurityInvalidLoginLockedOutcurrentInvalid Login: Locked Out
1.3.6.1.4.1.3607.2.20.0.5090NotificationgsecurityInvalidLoginAlreadyLoggedOncurrentInvalid Login: Already Logged On
1.3.6.1.4.1.3607.2.20.0.5100NotificationgloginOfUsercurrentLogin of User
1.3.6.1.4.1.3607.2.20.0.5110NotificationgautomaticLogoutOfIdleUsercurrentAutomatic Logout of IdleUser
1.3.6.1.4.1.3607.2.20.0.5120NotificationglogoutOfUsercurrentLogout of User
1.3.6.1.4.1.3607.2.20.0.5200NotificationgenhancedRemoteFailureIndicationPathServercurrentEnhanced Remote Failure Indication - Path - Server
1.3.6.1.4.1.3607.2.20.0.5210NotificationgenhancedRemoteFailureIndicationPathConnectivitycurrentEnhanced Remote Failure Indication - Path - Connectivity
1.3.6.1.4.1.3607.2.20.0.5220NotificationgenhancedRemoteFailureIndicationPathPayloadcurrentEnhanced Remote Failure Indication - Path - Payload
1.3.6.1.4.1.3607.2.20.0.5230NotificationgfirewallHasBeenDisabledcurrentFirewall Has Been Disabled
1.3.6.1.4.1.3607.2.20.0.5240NotificationgsecurityIntrusionDetPwdcurrentSecurity Intrusion - Incorrect Password
1.3.6.1.4.1.3607.2.20.0.5250NotificationgsecurityIntrusionDetUsercurrentSecurity Intrusion - Incorrect Username
1.3.6.1.4.1.3607.2.20.0.5260NotificationgconnectionEquipmentMismatchcurrentConnection Equipment Mismatch
1.3.6.1.4.1.3607.2.20.0.5270NotificationgdisableInactiveUsercurrentDisable Inactive User
1.3.6.1.4.1.3607.2.20.0.5280NotificationgdisableInactiveClearcurrentDisable Inactive Clear
1.3.6.1.4.1.3607.2.20.0.5290NotificationgbatteryFailurecurrentBattery Failure
1.3.6.1.4.1.3607.2.20.0.5300NotificationgextremeHighVoltcurrentExtreme High Volt
1.3.6.1.4.1.3607.2.20.0.5310NotificationgextremeLowVoltcurrentExtreme Low Volt
1.3.6.1.4.1.3607.2.20.0.5320NotificationghighVoltcurrentHigh Volt
1.3.6.1.4.1.3607.2.20.0.5330NotificationglowVoltcurrentLow Volt
1.3.6.1.4.1.3607.2.20.0.5340NotificationgsuspendUsercurrentSuspend User
1.3.6.1.4.1.3607.2.20.0.5350NotificationgsuspendUserClearcurrentSuspend User Clear
1.3.6.1.4.1.3607.2.20.0.5360NotificationglineDccTerminationFailurecurrentLine DCC Termination Failure
1.3.6.1.4.1.3607.2.20.0.5370NotificationgmultiplexSectionDccTerminationFailurecurrentMultiplex Section DCC Termination Failure
1.3.6.1.4.1.3607.2.20.0.5380NotificationggigaBitEthernetOutOfSynccurrentGigaBit Ethernet Out of Sync
1.3.6.1.4.1.3607.2.20.0.5390NotificationgsequenceMismatchcurrentSequence Mismatch
1.3.6.1.4.1.3607.2.20.0.5400NotificationglossOfAlignmentcurrentLoss of Alignment
1.3.6.1.4.1.3607.2.20.0.5410NotificationgoutOfUseByAdministrativeCommandcurrentOut of Use - Administrative Command
1.3.6.1.4.1.3607.2.20.0.5420NotificationgoutOfUseTransportFailurecurrentOut of Use - Transport Failure
1.3.6.1.4.1.3607.2.20.0.5430NotificationgvcatGroupDowncurrentVCAT Group Down
1.3.6.1.4.1.3607.2.20.0.5440NotificationgvcatGroupDegradedcurrentVCAT Group Degraded
1.3.6.1.4.1.3607.2.20.0.5450NotificationgvcatGroupIncompletecurrentVCAT Group Incomplete
1.3.6.1.4.1.3607.2.20.0.5460NotificationgalarmIndicationSignalInTXcurrentAlarm Indication Signal in TX
1.3.6.1.4.1.3607.2.20.0.5470NotificationgremoteAlarmIndicationInTXcurrentRemote Alarm Indication in TX
1.3.6.1.4.1.3607.2.20.0.5480NotificationgkByteAPSChannelFailurecurrentKbyte Channel Failure
1.3.6.1.4.1.3607.2.20.0.5490NotificationgapsInvalidModecurrentAPS Invalid Mode
1.3.6.1.4.1.3607.2.20.0.5500NotificationgipAddressAlreadyInUseWithinTheSameDccAreacurrentIP address already in use within the same DCC Area
1.3.6.1.4.1.3607.2.20.0.5510NotificationgnodeNameInUseWithinTheSameDccAreacurrentNode name already in use within the same DCC Area
1.3.6.1.4.1.3607.2.20.0.5520NotificationgrearPanelEthernetLinkRemovedcurrentRear Panel Ethernet Link Removed
1.3.6.1.4.1.3607.2.20.0.5530NotificationgmanualSwitchToProtectResultedInNoTrafficSwitchcurrentManual Switch To Protect Resulted in No Traffic Switch
1.3.6.1.4.1.3607.2.20.0.5540NotificationgmanualSwitchBackToWorkingResultedInNoTrafficSwitchcurrentManual Switch Back To Working Resulted in No Traffic Switch
1.3.6.1.4.1.3607.2.20.0.5550NotificationgforcedSwitchToProtectResultedInNoTrafficSwitchcurrentForced Switch To Protection Resulted in No Traffic Switch
1.3.6.1.4.1.3607.2.20.0.5560NotificationgforcedSwitchBackToWorkingResultedInNoTrafficSwitchcurrentForced Switch Back To Working Resulted in No Traffic Switch
1.3.6.1.4.1.3607.2.20.0.5570NotificationgduplicateSerialNumberDetectedOnAPluggableEntitycurrentDuplicate Serial number detected on a pluggable entity
1.3.6.1.4.1.3607.2.20.0.5600NotificationglossOfSignalForOpticalChannelcurrentIncoming Payload Signal Absent
1.3.6.1.4.1.3607.2.20.0.5610NotificationgencapsulationMismatchPathcurrentEncapsulation Type Mismatch
1.3.6.1.4.1.3607.2.20.0.5620NotificationgencapsulationMismatchVTcurrentEncapsulation Mismatch - VT
1.3.6.1.4.1.3607.2.20.0.5630NotificationgencapsulationMismatchHighOrderPathcurrentEncapsulation Mismatch High Order - Path
1.3.6.1.4.1.3607.2.20.0.5640NotificationgencapsulationMismatchLowOrderPathcurrentEncapsulation Mismatch Low Order - Path
1.3.6.1.4.1.3607.2.20.0.5650NotificationggfpUserPayloadMismatchcurrentGFP User Payload Mismatch
1.3.6.1.4.1.3607.2.20.0.5660NotificationggfpFibreChannelDistanceExtensionMismatchcurrentGFP Fibre Channel Distance Extension Mismatch
1.3.6.1.4.1.3607.2.20.0.5670NotificationggfpFibreChannelDistanceExtensionBufferStarvationcurrentGFP Fibre Channel Distance Extension Buffer Starvation
1.3.6.1.4.1.3607.2.20.0.5680NotificationggfpFibreChannelDistanceExtensionCreditStarvationcurrentFibre Channel Distance Extension Credit Starvation
1.3.6.1.4.1.3607.2.20.0.5690NotificationgautomaticWdmAnsFinishedcurrentAutomatic WDM ANS Finished
1.3.6.1.4.1.3607.2.20.0.5700NotificationggfpClientSignalFailDetectedcurrentGFP Client Signal Fail Detected
1.3.6.1.4.1.3607.2.20.0.5710NotificationggfpLossOfFrameDelineationcurrentGFP Loss of Frame Delineation
1.3.6.1.4.1.3607.2.20.0.5730NotificationggfpExtensionHeaderMismatchcurrentGFP Extension Header Mismatch
1.3.6.1.4.1.3607.2.20.0.5740NotificationgincomingOverheadSignalAbsentcurrentLoss of Signal for Overhead
1.3.6.1.4.1.3607.2.20.0.5750NotificationgopticalSafetyRemoteInterlockOncurrentOptical Safety Remote Interlock On
1.3.6.1.4.1.3607.2.20.0.5770NotificationgautomaticPowerControlCorrectionSkippedcurrentAutomatic Power Control Correction Skipped
1.3.6.1.4.1.3607.2.20.0.5780NotificationgapcCannotSetValueDueToRangeLimitscurrentAPC cannot set value due to range limits
1.3.6.1.4.1.3607.2.20.0.5790NotificationglcasVcgMemberTxSideInAddStatecurrentLCAS VCG Member Tx Side In ADD State
1.3.6.1.4.1.3607.2.20.0.5800NotificationgfarEndManualSwitchBackToWorkingSpancurrentFar End Manual Switch Back to Working - Span
1.3.6.1.4.1.3607.2.20.0.5810NotificationgfarEndForcedSwitchBackToWorkingSpancurrentFar End Forced Switch Back to Working - Span
1.3.6.1.4.1.3607.2.20.0.5820NotificationguniversalTransponderModuleHardwareFailurecurrentUniversal Transponder Module Hardware Failure
1.3.6.1.4.1.3607.2.20.0.5830NotificationguniversalTransponderModuleCommunicationFailurecurrentUniversal Transponder Module Communication Failure
1.3.6.1.4.1.3607.2.20.0.5840NotificationgpluginModuleRangeSettingsMismatchcurrentPlug-in Module Range Settings Mismatch
1.3.6.1.4.1.3607.2.20.0.5850NotificationglcasVcgMemberTxSideInDnuStatecurrentLCAS VCG Member Tx Side In DNU State
1.3.6.1.4.1.3607.2.20.0.5860NotificationglcasControlWordCrcCheckFailurecurrentLCAS Control Word CRC Check Failure
1.3.6.1.4.1.3607.2.20.0.5870NotificationglcasVcgMemberRxSideInFailStatecurrentLCAS VCG Member Rx Side In FAIL State
1.3.6.1.4.1.3607.2.20.0.5880NotificationgsignalLossOnDataInterfacecurrentSignal Loss on Data Interface
1.3.6.1.4.1.3607.2.20.0.5890NotificationgsynchronizationLossOnDataInterfacecurrentSynchronization Loss on Data Interface
1.3.6.1.4.1.3607.2.20.0.5900NotificationgportFAILcurrentPORT FAIL
1.3.6.1.4.1.3607.2.20.0.5910NotificationgunreachablePortTargetPowercurrentUnreachable port target power
1.3.6.1.4.1.3607.2.20.0.5920NotificationgportAddPowerDegradeLowcurrentPort Add Power Degrade Low
1.3.6.1.4.1.3607.2.20.0.5930NotificationgportAddPowerDegradeHighcurrentPort Add Power Degrade High
1.3.6.1.4.1.3607.2.20.0.5940NotificationgportAddPowerFailLowcurrentPort Add Power Fail Low
1.3.6.1.4.1.3607.2.20.0.5950NotificationgportAddPowerFailHighcurrentPort Add Power Fail High
1.3.6.1.4.1.3607.2.20.0.6000NotificationgautomaticPowerControlTerminatedOnManualRequestcurrentAutomatic Power Control Terminated on Manual request
1.3.6.1.4.1.3607.2.20.0.6010Notificationgoduk1AlarmIndicationSignalcurrentODUk-1: Alarm Indication Signal
1.3.6.1.4.1.3607.2.20.0.6020Notificationgoduk2AlarmIndicationSignalcurrentODUk-2: Alarm Indication Signal
1.3.6.1.4.1.3607.2.20.0.6030Notificationgoduk3AlarmIndicationSignalcurrentODUk-3: Alarm Indication Signal
1.3.6.1.4.1.3607.2.20.0.6040Notificationgoduk4AlarmIndicationSignalcurrentODUk-4: Alarm Indication Signal
1.3.6.1.4.1.3607.2.20.0.6050NotificationgtemperatureReadingMismatchBetweenSCCardscurrentTemperature Reading Mismatch Between SC Cards
1.3.6.1.4.1.3607.2.20.0.6060NotificationgvoltageReadingMismatchBetweenSCCardscurrentVoltage Reading Mismatch Between SC Cards
1.3.6.1.4.1.3607.2.20.0.6070NotificationgalarmsSuppressedonOutOfGroupVcatMembercurrentAlarms Suppressed on Out-Of-Group VCAT Member
1.3.6.1.4.1.3607.2.20.0.6080NotificationgblsrSoftwareVersionMismatchcurrentBLSR Software Version Mismatch
1.3.6.1.4.1.3607.2.20.0.6090Notificationgoptimized1Plus1ApsPrimaryFacilitycurrentOptimized 1+1 APS Primary Facility
1.3.6.1.4.1.3607.2.20.0.6100Notificationgoptimized1Plus1ApsPrimarySectionMismatchcurrentOptimized 1+1 APS Primary Section Mismatch
1.3.6.1.4.1.3607.2.20.0.6110Notificationgoptimized1Plus1ApsInvalidPrimarySectioncurrentOptimized 1+1 APS Invalid Primary Section
1.3.6.1.4.1.3607.2.20.0.6120NotificationgcompositeClockHighLineVoltagecurrentComposite Clock High Line Voltage
1.3.6.1.4.1.3607.2.20.0.6130NotificationgberThresholdExceededForSignalDegradeVtcurrentBER Threshold Exceeded For Signal Degrade - VT
1.3.6.1.4.1.3607.2.20.0.6140NotificationgberThresholdExceededForSignalFailureVtcurrentBER Threshold Exceeded For Signal Failure - VT
1.3.6.1.4.1.3607.2.20.0.6150NotificationgspanLengthOutOfRangecurrentSpan Length Out of Range
1.3.6.1.4.1.3607.2.20.0.6170NotificationgidleSignalConditioncurrentIdle Signal Condition
1.3.6.1.4.1.3607.2.20.0.6180NotificationgidleSignalConditionInTxcurrentIdle Signal Condition in TX
1.3.6.1.4.1.3607.2.20.0.6190NotificationgvtPathTraceIdentifierMismatchcurrentVT Path Trace Identifier Mismatch
1.3.6.1.4.1.3607.2.20.0.6200NotificationglossOfFrameInTXcurrentLoss of Frame in TX
1.3.6.1.4.1.3607.2.20.0.6210NotificationgprovisioningMismatchcurrentProvisioning Mismatch
1.3.6.1.4.1.3607.2.20.0.6220NotificationgsectionTraceIdentifierMismatchcurrentSection Trace Identifier Mismatch
1.3.6.1.4.1.3607.2.20.0.6230NotificationgregeneratorSectionTraceIdentifierMismatchcurrentRegenerator Section Trace Identifier Mismatch
1.3.6.1.4.1.3607.2.20.0.6240NotificationgswitchingMatrixModuleFailureWorkingcurrentSwitching Matrix Module Failure - Working
1.3.6.1.4.1.3607.2.20.0.6250NotificationgswitchingMatrixModuleFailureProtectcurrentSwitching Matrix Module Failure - Protect
1.3.6.1.4.1.3607.2.20.0.6260NotificationgslotCommunicationDisabledcurrentSlot Communication Disabled
1.3.6.1.4.1.3607.2.20.0.6270NotificationgsessionTimeLimitExpiredcurrentSession Time Limit Expired
1.3.6.1.4.1.3607.2.20.0.6280NotificationguserPasswordChangeRequiredcurrentUser Password Change Required
1.3.6.1.4.1.3607.2.20.0.6290NotificationgisisAdjacencyFailurecurrentISIS Adjacency Failure
1.3.6.1.4.1.3607.2.20.0.6300NotificationgmsspSoftwareVersionMismatchcurrentMSSP Software Version Mismatch
1.3.6.1.4.1.3607.2.20.0.6310NotificationgremoteAuthenticationFailSeeAuditLogcurrentRemote Authentication Fail - See Audit Log
1.3.6.1.4.1.3607.2.20.0.6320NotificationgillegalRouteAdditionToNetworkcurrentIllegal route addition to the Network
1.3.6.1.4.1.3607.2.20.0.6330NotificationgringIsSquelchingStsTrafficcurrentRing Is Squelching STS Traffic
1.3.6.1.4.1.3607.2.20.0.6340NotificationgringIsSquelchingVtTrafficcurrentRing Is Squelching VT Traffic
1.3.6.1.4.1.3607.2.20.0.6350NotificationgarchiveOfAuditLogFailedcurrentArchival of Audit Log Failed
1.3.6.1.4.1.3607.2.20.0.6360NotificationgrprWrappedcurrentRPR Wrapped
1.3.6.1.4.1.3607.2.20.0.6370NotificationgshelfCommunicationFailurecurrentShelf Communication Failure
1.3.6.1.4.1.3607.2.20.0.6380NotificationgduplicatedShelfIdentifiercurrentDuplicated Shelf Identifier
1.3.6.1.4.1.3607.2.20.0.6390NotificationgsoftwareMismatchcurrentSoftware Mismatch
1.3.6.1.4.1.3607.2.20.0.6400NotificationglmpFailurecurrentLMP Failure
1.3.6.1.4.1.3607.2.20.0.6410NotificationgopticalTerminationIncompletecurrentOptical Termination Incomplete
1.3.6.1.4.1.3607.2.20.0.6420NotificationgforwardDefectIndicationcurrentForward Defect Indication
1.3.6.1.4.1.3607.2.20.0.6430NotificationgpayloadMissingIndicationcurrentPayload Missing Indication
1.3.6.1.4.1.3607.2.20.0.6440NotificationgspanMeasurementCannotBePerformedcurrentSpan loss not checked
1.3.6.1.4.1.3607.2.20.0.6450NotificationgringIsSquelchingHighOrderTrafficcurrentRing Is Squelching Higher Order Traffic
1.3.6.1.4.1.3607.2.20.0.6460NotificationgringIsSquelchingLowOrderTrafficcurrentRing Is Squelching Lower Order Traffic
1.3.6.1.4.1.3607.2.20.0.6470NotificationgbadPacketCountExceedsThresholdcurrentBad Packet Count Exceeds Threshold
1.3.6.1.4.1.3607.2.20.0.6480NotificationglinkLayerKeepAliveFailurecurrentLink Layer Keep-Alive Failure
1.3.6.1.4.1.3607.2.20.0.6490NotificationgautonegotiationRemoteFailureIndicationcurrentAuto-Negotiation Remote Failure Indication
1.3.6.1.4.1.3607.2.20.0.6500NotificationgtrailSignalFailcurrentTrail Signal Fail
1.3.6.1.4.1.3607.2.20.0.6510Notificationgds1LoopbackCommandSentToFarEndcurrentDS1 Loopback Command Sent To Far End
1.3.6.1.4.1.3607.2.20.0.6520NotificationgmultiplexSectionSignalDegradedcurrentMultiplex Section - Signal Degraded
1.3.6.1.4.1.3607.2.20.0.6530NotificationgmultiplexSectionExcessiveErrorscurrentMultiplex Section - Excessive Errors
1.3.6.1.4.1.3607.2.20.0.6540NotificationghighOrderPathSignalDegradedcurrentHigh Order Path - Signal Degraded
1.3.6.1.4.1.3607.2.20.0.6550NotificationghighOrderPathExcessiveErrorscurrentHigh Order Path - Excessive Errors
1.3.6.1.4.1.3607.2.20.0.6560NotificationglowOrderPathSignalDegradedcurrentLow Order Path - Signal Degraded
1.3.6.1.4.1.3607.2.20.0.6570NotificationglowOrderPathExcessiveErrorscurrentLow Order Path - Excessive Errors
1.3.6.1.4.1.3607.2.20.0.6580NotificationgregeneratorSectionDccTerminationFailurecurrentRegenerator Section - DCC Termination Failure
1.3.6.1.4.1.3607.2.20.0.6590NotificationgnetworkMemoryPoolLowcurrentNetwork Memory Pool Low
1.3.6.1.4.1.3607.2.20.0.6600NotificationgospfRoutingTableOverflowcurrentOSPF Routing Table Overflow
1.3.6.1.4.1.3607.2.20.0.6610NotificationgautoLaserShutdownDisabledcurrentAuto Laser Shutdown Disabled
1.3.6.1.4.1.3607.2.20.0.6620NotificationgwavelengthOutOfLockcurrentWavelength Out of Lock
1.3.6.1.4.1.3607.2.20.0.6630NotificationgrprProtectionIsActivecurrentRPR Protection Is Active
1.3.6.1.4.1.3607.2.20.0.6640NotificationgmaxRPRStationNumberExceededcurrentMax RPR Station Number Exceeded
1.3.6.1.4.1.3607.2.20.0.6650NotificationgrprProtectionConfigurationMismatchedcurrentRPR Protection Configuration Mismatched
1.3.6.1.4.1.3607.2.20.0.6660NotificationgreservedBandwidthLinkRateExceededOnRinglet0currentReserved Bandwidth Link Rate Exceeded On Ringlet0
1.3.6.1.4.1.3607.2.20.0.6670NotificationgreservedBandwidthLinkRateExceededOnRinglet1currentReserved Bandwidth Link Rate Exceeded On Ringlet1
1.3.6.1.4.1.3607.2.20.0.6680NotificationgrprInterfaceInPassThroughModecurrentRPR Interface In Pass Through Mode
1.3.6.1.4.1.3607.2.20.0.6690NotificationgrprPeerNodeIsMissingcurrentRPR Peer Node is Missing
1.3.6.1.4.1.3607.2.20.0.6700NotificationgrprRiFailurecurrentRPR RI Failure
1.3.6.1.4.1.3607.2.20.0.6710NotificationgrprSignalFailurecurrentRPR Signal Failure
1.3.6.1.4.1.3607.2.20.0.6720NotificationgrprSignalDegradecurrentRPR Signal Degrade
1.3.6.1.4.1.3607.2.20.0.6730NotificationginterlinkFailurecurrentADM Peer Cards Interlink Failure
1.3.6.1.4.1.3607.2.20.0.6740NotificationgapcWrongGaincurrentAPC Wrong Gain Set Point
1.3.6.1.4.1.3607.2.20.0.6750NotificationgrprSpanMismatchcurrentRPR Span Mismatch
1.3.6.1.4.1.3607.2.20.0.6760NotificationgefmRemoteFaultIndicationCriticalEventcurrentEFM Remote Fault Indication- Critical Event
1.3.6.1.4.1.3607.2.20.0.6770NotificationgefmRemoteFaultIndicationDyingGaspcurrentEFM Remote Fault Indication- Dying Gasp
1.3.6.1.4.1.3607.2.20.0.6780NotificationgefmRemoteFaultIndicationLinkFaultcurrentEFM Remote Fault Indication- Link Fault
1.3.6.1.4.1.3607.2.20.0.6790NotificationgefmLinkMonitoringErroredSymbolPeriodEventcurrentEFM Link Monitoring- Errored Symbol Period Event
1.3.6.1.4.1.3607.2.20.0.6800NotificationgefmLinkMonitoringErroredFrameEventcurrentEFM Link Monitoring- Errored Frame Event
1.3.6.1.4.1.3607.2.20.0.6810NotificationgefmLinkMonitoringErroredFramePeriodEventcurrentEFM Link Monitoring- Errored Frame Period Event
1.3.6.1.4.1.3607.2.20.0.6820NotificationgefmLinkMonitoringErroredFrameSecondsSummarycurrentEFM Link Monitoring- Errored Frame Seconds Summary
1.3.6.1.4.1.3607.2.20.0.6830NotificationgefmRemoteLoopbackRequestFailedcurrentEFM Remote Loopback Request Failed
1.3.6.1.4.1.3607.2.20.0.6840NotificationgfastAutomaticProtectionSwitchingcurrentFast Automatic Protection Switching
1.3.6.1.4.1.3607.2.20.0.6850NotificationgfastAutomaticProtectionSwitchingConfigMismatchcurrentFast Automatic Protection Switching Config Mismatch
1.3.6.1.4.1.3607.2.20.0.6860NotificationglcasSinkGroupErrorcurrentLCAS Sink Group Error
1.3.6.1.4.1.3607.2.20.0.6870NotificationglcasVcgMemberRxSideInDnuStatecurrentLCAS VCG Member Rx Side In DNU State
1.3.6.1.4.1.3607.2.20.0.6880NotificationgfcDistanceExtFuncNotEstablishedcurrentFibre Channel Distance Extension Function Not Established
1.3.6.1.4.1.3607.2.20.0.6890NotificationgnonCiscoPPMInsertedcurrentNon Cisco PPM Inserted
1.3.6.1.4.1.3607.2.20.0.6900NotificationgunqualifiedPPMInsertedcurrentUnqualified PPM Inserted
1.3.6.1.4.1.3607.2.20.0.6910NotificationgftaMismatchcurrentFanTray Mismatch
1.3.6.1.4.1.3607.2.20.0.6920NotificationgcardPortsUnableToProvideProtectioncurrentCard/Ports Unable To Provide Protection
1.3.6.1.4.1.3607.2.20.0.6930NotificationglmpSignalDegradecurrentLMP Signal Degrade
1.3.6.1.4.1.3607.2.20.0.6940NotificationglmpSignalFailurecurrentLMP Signal Failure
1.3.6.1.4.1.3607.2.20.0.6950NotificationglmpUnallocatedDataLinkcurrentLMP Unallocated Data Link
1.3.6.1.4.1.3607.2.20.0.6960NotificationgfrontPortLinkLosscurrentTCC Front Port Link Loss
1.3.6.1.4.1.3607.2.20.0.6970NotificationgbertEnblcurrentBERT Enabled
1.3.6.1.4.1.3607.2.20.0.6975NotificationgbertSyncFailcurrentBERT Synchronization Status Failed
1.3.6.1.4.1.3607.2.20.0.6980NotificationgworkQueueFullcurrentWork Queue Full
1.3.6.1.4.1.3607.2.20.0.7000NotificationgequipmentPowerFailureAtConnectorAcurrentEquipment Power Failure At Connector A
1.3.6.1.4.1.3607.2.20.0.7005NotificationgequipmentPowerFailureAtConnectorBcurrentEquipment Power Failure At Connector B
1.3.6.1.4.1.3607.2.20.0.7010NotificationgequipmentPowerFailureAtReturnConnectorAcurrentEquipment Power Failure At Return Connector A
1.3.6.1.4.1.3607.2.20.0.7015NotificationgequipmentPowerFailureAtReturnConnectorBcurrentEquipment Power Failure At Return Connector B
1.3.6.1.4.1.3607.2.20.0.7020NotificationgloginFailThresholdExceededcurrentInvalid login attempt threshold exceeded
1.3.6.1.4.1.3607.2.20.0.7025NotificationgconnectionIdMismatchOnMatrixAcurrentConnection ID mismatch on Matrix A
1.3.6.1.4.1.3607.2.20.0.7030NotificationgconnectionIdMismatchOnMatrixBcurrentConnection ID mismatch on Matrix B
1.3.6.1.4.1.3607.2.20.0.7035NotificationgmanufacturingEepromFailuredeprecatedManufacturing data memory (EEPROM) failure
1.3.6.1.4.1.3607.2.20.0.7040NotificationgequipmentFailureHighTemperaturecurrentEquipment failure high temperature
1.3.6.1.4.1.3607.2.20.0.7045NotificationglaserBiasCurrentHighcurrentLaser bias current high
1.3.6.1.4.1.3607.2.20.0.7050NotificationghighLaserTemperaturecurrentHigh laser temperature
1.3.6.1.4.1.3607.2.20.0.7055NotificationgbridgeAndRollHasOccurredcurrentBridge and Roll Has Occurred
1.3.6.1.4.1.3607.2.20.0.7060NotificationgbridgeAndRollIsPendingAValidSignalcurrentBridge and Roll is Pending a Valid Signal
1.3.6.1.4.1.3607.2.20.0.7065NotificationgairFlowdeprecatedAir Flow
1.3.6.1.4.1.3607.2.20.0.7070NotificationgpartialFanFailurePartsFailurecurrentPartial Fan Failure - Parts Failure
1.3.6.1.4.1.3607.2.20.0.7075NotificationgunprotectedSyncronizationEquipmentcurrentUnprotected Synchronization Equipment
1.3.6.1.4.1.3607.2.20.0.7080NotificationgunprotectedMatrixEquipmentcurrentUnprotected Matrix Equipment
1.3.6.1.4.1.3607.2.20.0.7085NotificationgmatrixEquipmentUnavailablecurrentMatrix Equipment Unavailable
1.3.6.1.4.1.3607.2.20.0.7090NotificationgcontrolBusFailureTscAcurrentControl Bus Failure - TSC A
1.3.6.1.4.1.3607.2.20.0.7095NotificationgcontrolBusFailureTscBcurrentControl Bus Failure - TSC B
1.3.6.1.4.1.3607.2.20.0.7100NotificationgpayloadBusFailureMatrixAcurrentPayload Bus Failure - Matrix A
1.3.6.1.4.1.3607.2.20.0.7105NotificationgpayloadBusFailureMatrixBcurrentPayload Bus Failure - Matrix B
1.3.6.1.4.1.3607.2.20.0.7110NotificationgmatrixOperationSuspendedcurrentMatrix Operation Suspended
1.3.6.1.4.1.3607.2.20.0.7115NotificationgclockFailureTsccurrentClock Module Failure
1.3.6.1.4.1.3607.2.20.0.7120NotificationgpayloadLoopbackcurrentLoopback - Payload
1.3.6.1.4.1.3607.2.20.0.7125NotificationgdccChannelLosscurrentDCC Channel Loss
1.3.6.1.4.1.3607.2.20.0.7130NotificationgreptPmMsgInhibitedcurrentAutonomous PM Report Message Inhibited
1.3.6.1.4.1.3607.2.20.0.7135NotificationgloopbackCrscurrentLoopback - Cross Connect
1.3.6.1.4.1.3607.2.20.0.7140NotificationgsyncRefFreqOutOfBoundcurrentSynchronization Reference Frequency Out Of Bounds
1.3.6.1.4.1.3607.2.20.0.7145NotificationgsystemUpgradeInProgresscurrentSystem Upgrade In Progress
1.3.6.1.4.1.3607.2.20.0.7150NotificationgeqptFailToBootcurrentEquipment Fails To Boot
1.3.6.1.4.1.3607.2.20.0.7155NotificationgeqptPowerFailurecurrentEquipment Power Failure
1.3.6.1.4.1.3607.2.20.0.7160NotificationgclockBusFailureTscAcurrentClock Bus Failure - Shelf Controller A
1.3.6.1.4.1.3607.2.20.0.7165NotificationgclockBusFailureTscBcurrentClock Bus Failure - Shelf Controller B
1.3.6.1.4.1.3607.2.20.0.7170NotificationgpowerFuseFailurecurrentPower Fuse Failure
1.3.6.1.4.1.3607.2.20.0.7175NotificationgcontrolCommunicationsEquipmentFailurecurrentControl Communication Equipment Failure
1.3.6.1.4.1.3607.2.20.0.7180NotificationgdifferentSoftwareVersioncurrentDifferent Software Version
1.3.6.1.4.1.3607.2.20.0.7185NotificationgospfHelloFailcurrentOSPF Hello Fail
1.3.6.1.4.1.3607.2.20.0.7190NotificationgclockModuleFrequencyMismatchcurrentClock Module Frequency Mismatch
1.3.6.1.4.1.3607.2.20.0.7195NotificationgetherPortSwitchcurrentTSC switched to alternate ethernet port
1.3.6.1.4.1.3607.2.20.0.7200NotificationgopenIOSlotscurrentOpen IO Slot(s)
1.3.6.1.4.1.3607.2.20.0.7205NotificationgequipmentBootInProgresscurrentEquipment boot in-progress.
1.3.6.1.4.1.3607.2.20.0.7210NotificationglossOfClockFromMateShelfControllercurrentLoss of Clock from mate Shelf Controller
1.3.6.1.4.1.3607.2.20.0.7225NotificationgvirtualLanAlarmIndicationSignalcurrentVirtual Lan AIS
1.3.6.1.4.1.3607.2.20.0.7230NotificationgdcuLossFailurecurrentDCU Loss Failure
1.3.6.1.4.1.3607.2.20.0.7235NotificationgochncMaintenancecurrentOCHNC Maintenance
1.3.6.1.4.1.3607.2.20.0.7240NotificationgramanLaserShutdowncurrentRaman Laser Shutdown
1.3.6.1.4.1.3607.2.20.0.7245NotificationglosOfRamanSignalcurrentLoss Of Raman Signal
1.3.6.1.4.1.3607.2.20.0.7250NotificationgmcastMacTableFullcurrentMulticast Mac Address Table Full
1.3.6.1.4.1.3607.2.20.0.7255NotificationgmulticastMacAddressAliasingcurrentMulticast Mac Address Aliasing
1.3.6.1.4.1.3607.2.20.0.7260NotificationgramanPwrProtOncurrentRaman Power Protection On
1.3.6.1.4.1.3607.2.20.0.7265NotificationgcppPeerNotRespondingcurrentCPP Peer Not Responding
1.3.6.1.4.1.3607.2.20.0.7275NotificationgvoaControlLoopDisableDueToExcessiveCounterPropagationLightcurrentVOA Control Loop Disable Due To Excessive Counter-Propagation Light
1.3.6.1.4.1.3607.2.20.0.7280NotificationgwizardIsRunningcurrentWizard Is Running
1.3.6.1.4.1.3607.2.20.0.7285NotificationgramanGainNotReachedcurrentRaman Span Not Tuned
1.3.6.1.4.1.3607.2.20.0.7295NotificationgpprForwardDefectIndicationcurrentpprForwardDefectIndication
1.3.6.1.4.1.3607.2.20.0.7300NotificationgpprBackwardDefectIndicationcurrentpprBackwardDefectIndication
1.3.6.1.4.1.3607.2.20.0.7305NotificationgpprCoordinatedMaintenancecurrentpprCoordinatedMaintenance
1.3.6.1.4.1.3607.2.20.0.7310NotificationgpprTriggerThresholdBERExceededcurrentpprTriggerThresholdBERExceeded
1.3.6.1.4.1.3607.2.20.0.7315NotificationglocalFaultcurrentLocal Fault
1.3.6.1.4.1.3607.2.20.0.7320NotificationgremoteFaultcurrentRemote Fault
1.3.6.1.4.1.3607.2.20.0.7325NotificationgefmRemoteLoopbackConfiguredcurrentEFM Port In Remote Loopback
1.3.6.1.4.1.3607.2.20.0.7330NotificationgefmPeerMissingcurrentEFM Link To Peer Missing
1.3.6.1.4.1.3607.2.20.0.7335NotificationgeqptDegradecurrentEquipment Degrade
1.3.6.1.4.1.3607.2.20.0.7340NotificationgexcessiveBackPropagationcurrentExcessive Back Propagation
1.3.6.1.4.1.3607.2.20.0.7345NotificationgremoteMaintenanceEndPointIsDowncurrentCFM Remote Maintenance End Point Is Down
1.3.6.1.4.1.3607.2.20.0.7350NotificationgcrossConnectedCFMServicecurrentCross Connected CFM Service
1.3.6.1.4.1.3607.2.20.0.7355NotificationgcfmLoopcurrentCFM Loop
1.3.6.1.4.1.3607.2.20.0.7360NotificationgcfmConfigurationErrorcurrentCFM Configuration Error
1.3.6.1.4.1.3607.2.20.0.7365NotificationgoutOfChannelGroupBundlecurrentOut Of Channel Group Bundle
1.3.6.1.4.1.3607.2.20.0.7370NotificationgrepNeighborAdjacencyFailurecurrentREP Neighbor Adjacency Failure
1.3.6.1.4.1.3607.2.20.0.7375NotificationgrepLinkFlappingcurrentREP Link Flapping
1.3.6.1.4.1.3607.2.20.0.7380NotificationgfaultInREPSegmentcurrentFault In REP Segment
1.3.6.1.4.1.3607.2.20.0.7385NotificationgprimaryREPEdgePortElectedcurrentPrimary REP Edge Port Elected
1.3.6.1.4.1.3607.2.20.0.7390NotificationgsecondaryREPEdgePortElectedcurrentSecondary REP Edge Port Elected
1.3.6.1.4.1.3607.2.20.0.7395NotificationgstcnREPGeneratedcurrentSTCN REP Generated
1.3.6.1.4.1.3607.2.20.0.7400NotificationgvlbREPActivatedcurrentVLB REP Activated
1.3.6.1.4.1.3607.2.20.0.7405NotificationgvlbREPTriggerSoakingDelayActivecurrentVLB REP Trigger Soaking Delay Active
1.3.6.1.4.1.3607.2.20.0.7410NotificationgwanSynclosscurrentEthernet Syncloss On WAN Port
1.3.6.1.4.1.3607.2.20.0.7415NotificationglaserShutdownDueToWavelengthDriftcurrentlaser Shutdown Due To Wavelength Drift
1.3.6.1.4.1.3607.2.20.0.7420NotificationgmanualLaserRestartcurrentmanual Laser Restart
1.3.6.1.4.1.3607.2.20.0.7425NotificationglaserShutdownDueToNonCiscoPPMInsertedcurrentlaserShutdownDueToNonCiscoPPMInserted
1.3.6.1.4.1.3607.2.20.0.7430NotificationgethernetOSCTerminationFailurecurrentEthernet OSC Termination Failure
1.3.6.1.4.1.3607.2.20.0.7445NotificationgsoftwareSignatureVerificationFailedcurrentsoftware Signature Verification Failed
1.3.6.1.4.1.3607.2.20.0.7450NotificationgprotectVolumeSoftwareSignatureVerificationFailedcurrentProtect Volume Software Signature Verification
1.3.6.1.4.1.3607.2.20.0.7455NotificationgactiveVolumeSoftwareSignatureVerificationFailedcurrentActive Software Signature Verification Failed
1.3.6.1.4.1.3607.2.20.0.7460NotificationgpeerPortClientSignalFailDetectedcurrentPeer Port Client Signal Fail Detected
1.3.6.1.4.1.3607.2.20.0.7465NotificationgchannelShutdownDuetoWavelengthDriftcurrentChannel Shutdown Due to Wavelength Drift
1.3.6.1.4.1.3607.2.20.0.7475NotificationgusbWriteFailurecurrentUSB Write Failure
1.3.6.1.4.1.3607.2.20.0.7480NotificationgusbSyncInProgresscurrentUSB Sync in Progress
1.3.6.1.4.1.3607.2.20.0.7485NotificationgautoSensingUnableToDetectValidPayloadcurrentAuto-Sensing Unable To Detect Valid Payload
1.3.6.1.4.1.3607.2.20.0.7490NotificationgpayloadAutoSensingInProgresscurrentPayload Auto-Sensing In Progress
1.3.6.1.4.1.3607.2.20.0.7495NotificationggfpClientSignalFailDetectedDueToSiglosscurrentGFP Client Signal Fail Detected Due To Sigloss
1.3.6.1.4.1.3607.2.20.0.7500NotificationggfpClientSignalFailDetectedDueToSynclosscurrentGFP Client Signal Fail Detected Due To Syncloss
1.3.6.1.4.1.3607.2.20.0.7510NotificationgpmdDegradecurrentPMD Degrade
1.3.6.1.4.1.3607.2.20.0.7515NotificationgstandbyTccNEClockIsInternalClockcurrentStandby Tcc NE Clock Is Internal Clock
1.3.6.1.4.1.3607.2.20.0.7520NotificationgchromaticDispersionValuecurrentchromatic Dispersion Value
1.3.6.1.4.1.3607.2.20.0.7525NotificationgpacketTransportServiceFailedcurrentpacketTransportServiceFailed
1.3.6.1.4.1.3607.2.20.0.7530NotificationgsatellitePanelDiscoveryFailurecurrentSatellite Panel Discovery Failure
1.3.6.1.4.1.3607.2.20.0.7535NotificationgsatellitePanelActiveLinkFailurecurrentSatellite Panel Active Link Failure
1.3.6.1.4.1.3607.2.20.0.7540NotificationgsatellitePanelCommunicationFailurecurrentSatellite Panel Communication Failure
1.3.6.1.4.1.3607.2.20.0.7545NotificationgsatellitePanelImproperConfigurationcurrentSatellite Panel Improper Configuration
1.3.6.1.4.1.3607.2.20.0.7550NotificationgsatellitePanelFanMismatchOfEquipmentAndAttributescurrentSatellite Panel Fan Mismatch Of Equipment And Attributes
1.3.6.1.4.1.3607.2.20.0.7555NotificationgsatellitePanelFanFailurecurrentSatellite Panel Fan Failure
1.3.6.1.4.1.3607.2.20.0.7560NotificationgsatellitePanelPartialFanFailurecurrentSatellite Panel Partial Fan Failure
1.3.6.1.4.1.3607.2.20.0.7565NotificationgsatellitePanelFANManufacturingDataMemoryEEPROMFailurecurrentSatellite Panel FAN Manufacturing Data Memory (EEPROM) Failure
1.3.6.1.4.1.3607.2.20.0.7570NotificationgsatellitePanelFANUnitIsMissingcurrentSatellite Panel FAN Unit Is Missing
1.3.6.1.4.1.3607.2.20.0.7575NotificationgsatellitePanelIndustrialHighTemperaturecurrentSatellite Panel Industrial High Temperature
1.3.6.1.4.1.3607.2.20.0.7580NotificationgsatellitePanelHighTemperaturecurrentSatellite Panel High Temperature
1.3.6.1.4.1.3607.2.20.0.7585NotificationgsatellitePanelBatteryFailureAcurrentSatellite Panel Battery Failure A
1.3.6.1.4.1.3607.2.20.0.7590NotificationgplannedSwitchOvercurrentPlanned Switch Over
1.3.6.1.4.1.3607.2.20.0.7595NotificationgprotectionCardConfigurationMismatchcurrentprotection Card Configuration Mismatch
1.3.6.1.4.1.3607.2.20.0.7600NotificationgrouterProcessorSwitchOvercurrentRouter Processor Switch Over
1.3.6.1.4.1.3607.2.20.0.7605NotificationgrunningLowOnResourcescurrentRunning Low On Resources
1.3.6.1.4.1.3607.2.20.0.7610NotificationgnoMoreResourcesAreAvailablecurrentNo More Resources Are Available
1.3.6.1.4.1.3607.2.20.0.7615NotificationgesmcFailurecurrentESMC Failure
1.3.6.1.4.1.3607.2.20.0.7620NotificationglicenseWillExpireWithin24Hourscurrentlicense Will Expire Within 24 Hours
1.3.6.1.4.1.3607.2.20.0.7625NotificationglicenseWillExpireAnytimeAfter1DayButBefore14Dayscurrentlicense Will Expire Anytime After 1Day But Before 14 Days
1.3.6.1.4.1.3607.2.20.0.7630NotificationglicenseIsExpiredcurrentlicense Is Expired
1.3.6.1.4.1.3607.2.20.0.7635NotificationglicenseCountViolationcurrentlicense Count Violation
1.3.6.1.4.1.3607.2.20.0.7640NotificationgtemporaryLicenseIsInUsecurrentTemporary License Is In Use
1.3.6.1.4.1.3607.2.20.0.7645NotificationgevaluationLicenseIsInUsecurrentEvaluation License Is In Use
1.3.6.1.4.1.3607.2.20.0.7650NotificationglicenseIsMissingcurrentLicense Is Missing
1.3.6.1.4.1.3607.2.20.0.7655NotificationgpseudowireDowncurrentPseudowire Down
1.3.6.1.4.1.3607.2.20.0.7660NotificationgworkingPseudowireControlPlaneDowncurrentWorking Pseudowire Control Plane Down
1.3.6.1.4.1.3607.2.20.0.7665NotificationgprotectPseudowireControlPlaneDowncurrentProtect Pseudowire Control Plane Down
1.3.6.1.4.1.3607.2.20.0.7670NotificationgworkingPseudowireConnectivityCheckDowncurrentWorking Pseudowire Connectivity Check Down
1.3.6.1.4.1.3607.2.20.0.7675NotificationgprotectPseudowireConnectivityCheckDowncurrentProtect Pseudowire Connectivity Check Down
1.3.6.1.4.1.3607.2.20.0.7680NotificationgpseudowireTrafficSwitchedToPretectioncurrentPseudowire Traffic Switched To Pretection
1.3.6.1.4.1.3607.2.20.0.7685NotificationgworkingPseudowireLocalAcTxPortFaultcurrentWorking Pseudowire Local AcTx Port Fault
1.3.6.1.4.1.3607.2.20.0.7690NotificationgprotectPseudowireLocalAcTxPortFaultcurrentProtect Pseudowire Local AcTx Port Fault
1.3.6.1.4.1.3607.2.20.0.7695NotificationgworkingPseudowireLocalAcRxPortFaultcurrentWorking Pseudowire Local AcRx Port Fault
1.3.6.1.4.1.3607.2.20.0.7700NotificationgprotectPseudowireLocalAcRxPortFaultcurrentProtect Pseudowire Local AcRx Port Fault
1.3.6.1.4.1.3607.2.20.0.7705NotificationgworkingPseudowireRemoteAcTxPortFaultcurrentWorking Pseudowire Remote AcTx Port Fault
1.3.6.1.4.1.3607.2.20.0.7710NotificationgprotectPseudowireRemoteAcTxPortFaultcurrentProtect Pseudowire Remote AcTx Port Fault
1.3.6.1.4.1.3607.2.20.0.7715NotificationgworkingPseudowireRemoteAcRxPortFaultcurrentworking Pseudowire Remote AcRx Port Fault
1.3.6.1.4.1.3607.2.20.0.7720NotificationgprotectPseudowireRemoteAcRxPortFaultcurrentProtect Pseudowire Remote AcRx Port Fault
1.3.6.1.4.1.3607.2.20.0.7725NotificationgslaThresholdCrossAlertcurrentSLA Threshold Cross Alert
1.3.6.1.4.1.3607.2.20.0.7730NotificationgprotectLocalPseudowireNotForwardingcurrentProtect Local Pseudowire Not Forwarding
1.3.6.1.4.1.3607.2.20.0.7735NotificationgworkingRemotePseudowireNotForwardingcurrentWorking Remote Pseudowire Not Forwarding
1.3.6.1.4.1.3607.2.20.0.7740NotificationgprotectRemotePseudowireNotForwardingcurrentProtect Remote Pseudowire Not Forwarding
1.3.6.1.4.1.3607.2.20.0.7745NotificationgtpTunnelDowncurrentTp Tunnel Down
1.3.6.1.4.1.3607.2.20.0.7750NotificationgworkingLabelSwitchedPathDowncurrentWorking Label Switched Path Down
1.3.6.1.4.1.3607.2.20.0.7755NotificationgprotectLabelSwitchedPathDowncurrentProtect Label Switched Path Down
1.3.6.1.4.1.3607.2.20.0.7760NotificationgworkingLabelSwitchedPathAlarmIndicationSignalcurrentWorking Label Switched Path Alarm Indication Signal
1.3.6.1.4.1.3607.2.20.0.7765NotificationgprotectLabelSwitchedPathAlarmIndicationSignalcurrentProtect Label Switched Path Alarm Indication Signal
1.3.6.1.4.1.3607.2.20.0.7770NotificationgworkingLabelSwitchedPathRemoteDefectIndicationcurrentWorking Label Switched Path Remote Defect Indication
1.3.6.1.4.1.3607.2.20.0.7775NotificationgprotectLabelSwitchedPathRemoteDefectIndicationcurrentProtect Label Switched Path Remote Defect Indication
1.3.6.1.4.1.3607.2.20.0.7780NotificationgbidirectionalForwardDetectionDowncurrentBidirectional Forward Detection Down
1.3.6.1.4.1.3607.2.20.0.7785NotificationgtpTrafficSwitchedFromWorkingToProtectioncurrentTp Traffic Switched From Working To Protection
1.3.6.1.4.1.3607.2.20.0.7790NotificationgworkingTpLockoutcurrentworking Tp Lockout
1.3.6.1.4.1.3607.2.20.0.7795NotificationgprotectTpLockoutcurrentprotect Tp Lockout
1.3.6.1.4.1.3607.2.20.0.7800NotificationgethernetFlowPointFailedcurrentEthernet Flow Point Failed
1.3.6.1.4.1.3607.2.20.0.7805NotificationgteTunnelDowncurrentTE Tunnel Down
1.3.6.1.4.1.3607.2.20.0.7810NotificationgmacSystemLimitReachedcurrentMAC System Limit Reached
1.3.6.1.4.1.3607.2.20.0.7815NotificationgmacBridgeDomainLimitReachedcurrentMAC Bridge Domain Limit Reached
1.3.6.1.4.1.3607.2.20.0.7820NotificationgautoSensingDisabledcurrentAuto Sense Disabled
1.3.6.1.4.1.3607.2.20.0.7825NotificationgsmBackwardIncomingAlignmentErrorcurrentSM Backward Incoming Alignment Error
1.3.6.1.4.1.3607.2.20.0.7830NotificationgresourceAllocationFailedcurrentResource Allocation Failed
1.3.6.1.4.1.3607.2.20.0.7835NotificationglossOfDFBSignalcurrentloss Of DFB Signal
1.3.6.1.4.1.3607.2.20.0.7840NotificationgworkingLabelSwitchedPathLinkDownIndicationcurrentWorking Label Switched Path Link Down Indication
1.3.6.1.4.1.3607.2.20.0.7845NotificationgprotectLabelSwitchedPathLinkDownIndicationcurrentProtect Label Switched Path Link Down Indication
1.3.6.1.4.1.3607.2.20.0.7850NotificationgworkingLabelSwitchedPathLockReportcurrentWorking Label Switched Path Lock Report
1.3.6.1.4.1.3607.2.20.0.7855NotificationgprotectLabelSwitchedPathLockReportcurrentProtect Label Switched Path Lock Report
1.3.6.1.4.1.3607.2.20.0.7860NotificationgsatellitePanelBatteryFailureBcurrentsatellite Panel Battery FailureB
1.3.6.1.4.1.3607.2.20.0.7865NotificationghighBitErrorRatecurrentHigh Bit Error Rate
1.3.6.1.4.1.3607.2.20.0.7870NotificationgbackPanelFacilityLoopbackcurrentBack Panel Facility Loopback
1.3.6.1.4.1.3607.2.20.0.7875NotificationgbackPanelTerminalLoopbackcurrentBack Panel Terminal Loopback
1.3.6.1.4.1.3607.2.20.0.7880NotificationgtrunkPayloadTypeMismatchcurrentPayload Mismatch
1.3.6.1.4.1.3607.2.20.0.7885NotificationginvalidMuxponderConfigurationcurrentInvalid Muxponder Configuration
1.3.6.1.4.1.3607.2.20.0.7890NotificationgcoolingProfileMismatchcurrentCooling Profile Mismatch
1.3.6.1.4.1.3607.2.20.0.7895NotificationgtrunkOduAlarmIndicationSignalcurrentTrunk ODU: Alarm Indication Signal
1.3.6.1.4.1.3607.2.20.0.7900NotificationgcompanionCardMissingcurrentCompanion Card Missing
1.3.6.1.4.1.3607.2.20.0.7905NotificationgcontrolPlaneUnverifiedClearedAlarmsPresentcurrentControl Plane Unverified Cleared Alarms Present
1.3.6.1.4.1.3607.2.20.0.7910NotificationgpowerConsumptionLimitHasCrossedcurrentPower Consumption Limit Has Crossed
1.3.6.1.4.1.3607.2.20.0.7915NotificationgmasterKeyExchangeFailedcurrentMaster Key Exchange Failed
1.3.6.1.4.1.3607.2.20.0.7930NotificationgunitHighTemperaturecurrentUnit High Temperature
1.3.6.1.4.1.3607.2.20.0.7935NotificationgoverTemperatureUnitProtectedcurrentOver Temperature Unit Protected
1.3.6.1.4.1.3607.2.20.0.7945NotificationgseqMismatchCountcurrentSequence Mismatch Count
1.3.6.1.4.1.3607.2.20.0.7960NotificationgkeyProgramOnAlteraFpgaFailedcurrentKey Program On Altera FPGA Failed
1.3.6.1.4.1.3607.2.20.0.7970NotificationgduplicateNodeControllerDetectedcurrentDuplicate Node Controller Detected
1.3.6.1.4.1.3607.2.20.0.7975NotificationgrestorationInProgcurrentRestoration in Progress
1.3.6.1.4.1.3607.2.20.0.7980NotificationgramanPumpsCalibrationProcedureIsRunningcurrentRaman Calibration Running
1.3.6.1.4.1.3607.2.20.0.7985NotificationgramanPumpsCalibrationIsScheduledToRunInTheNextMinutescurrentRaman Calibration Pending
1.3.6.1.4.1.3607.2.20.0.13100NotificationgodukTCM1AlarmIndicationSignalcurrentODUk Alarm Indication Signal TCM1
1.3.6.1.4.1.3607.2.20.0.13105NotificationgodukTCM2AlarmIndicationSignalcurrentODUk Alarm Indication Signal TCM2
1.3.6.1.4.1.3607.2.20.0.13110NotificationgodukLockedDefectTCM1currentODUk Locked Defect - TCM1
1.3.6.1.4.1.3607.2.20.0.13115NotificationgodukLockedDefectTCM2currentODUk Locked Defect - TCM2
1.3.6.1.4.1.3607.2.20.0.13120NotificationgotukLossOfFramecurrentOTUk: Loss Of Frame
1.3.6.1.4.1.3607.2.20.0.13125NotificationgodukOpenConnectionIndicationTCM1currentODUk Open Connection Indication TCM1
1.3.6.1.4.1.3607.2.20.0.13130NotificationgodukOpenConnectionIndicationTCM2currentODUk Open Connection Indication TCM2
1.3.6.1.4.1.3607.2.20.0.13135NotificationgodukTrailTraceIdentifierMismatchTCM1currentODUk Trail Trace Identifier Mismatch TCM1
1.3.6.1.4.1.3607.2.20.0.13140NotificationgodukTrailTraceIdentifierMismatchTCM2currentODUk Trail Trace Identifier Mismatch TCM2
1.3.6.1.4.1.3607.2.20.0.13145NotificationgodukSignalFailureTCM1currentODUk Signal Failure - TCM1
1.3.6.1.4.1.3607.2.20.0.13150NotificationgodukSignalFailureTCM2currentODUk Signal Failure - TCM2
1.3.6.1.4.1.3607.2.20.0.13155NotificationgodukSignalDegradeTCM1currentODUk Signal Degrade - TCM1
1.3.6.1.4.1.3607.2.20.0.13160NotificationgodukSignalDegradeTCM2currentODUk Signal Degrade - TCM2
1.3.6.1.4.1.3607.2.20.0.13165NotificationglossOfChannelcurrentLoss of Channel
1.3.6.1.4.1.3607.2.20.0.13170NotificationgfecMismatchcurrentFEC Mismatch
1.3.6.1.4.1.3607.2.20.0.13175NotificationgtimSectionMonitorTraceIdentifierMismatchFailurecurrentTIM Section Monitor - Trace Identifier Mismatch Failure
1.3.6.1.4.1.3607.2.20.0.13180NotificationgautomaticLaserShutdowncurrentAutomatic Laser Shutdown
1.3.6.1.4.1.3607.2.20.0.13200NotificationgshutterInsertionLossVariationDegradeLowcurrentShutter Insertion Loss Variation Degrade Low
1.3.6.1.4.1.3607.2.20.0.13205NotificationgopticalChannelDeactivationFailurecurrentOptical Channel de-activation failure
1.3.6.1.4.1.3607.2.20.0.13210NotificationgshutterInsertionLossVariationDegradeHighcurrentShutter Insertion Loss Variation Degrade High
1.3.6.1.4.1.3607.2.20.0.13215NotificationgnetworkTopologyIncompletecurrentNetwork Topology Incomplete
1.3.6.1.4.1.3607.2.20.0.13220NotificationgpluginModuleCommunicationFailurecurrentPlug-in Module Communication Failure
1.3.6.1.4.1.3607.2.20.0.13225NotificationgopticalNetworkTypeMismatchcurrentOptical Network Type Mismatch
1.3.6.1.4.1.3607.2.20.0.13230NotificationgopticalPowerDegradeLowcurrentLaser Power Degrade Low
1.3.6.1.4.1.3607.2.20.0.13235NotificationgautomaticPowerControlFailurecurrentAutomatic Power Control Failure
1.3.6.1.4.1.3607.2.20.0.13240NotificationgopticalPowerDegradeHighcurrentOptical Power Degrade High
1.3.6.1.4.1.3607.2.20.0.13245NotificationgautomaticPowerControlDisabledcurrentAutomatic Power Control Disabled
1.3.6.1.4.1.3607.2.20.0.13250NotificationgopticalPowerFailureLowcurrentOptical Power Failure Low
1.3.6.1.4.1.3607.2.20.0.13255NotificationgringIdMismatchcurrentRing Id Mismatch
1.3.6.1.4.1.3607.2.20.0.13260NotificationgopticalPowerFailureHighcurrentOptical Power Failure High
1.3.6.1.4.1.3607.2.20.0.13270NotificationglossOfContinuitycurrentLoss Of Continuity
1.3.6.1.4.1.3607.2.20.0.13280NotificationgvariableOpticalAttenuatorDegradeLowcurrentVariable Optical Attenuator Degrade Low
1.3.6.1.4.1.3607.2.20.0.13290NotificationgvariableOpticalAttenuatorDegradeHighcurrentVariable Optical Attenuator Degrade High
1.3.6.1.4.1.3607.2.20.0.13300NotificationgvariableOpticalAttenuatorFailureLowcurrentVariable Optical Attenuator Failure Low
1.3.6.1.4.1.3607.2.20.0.13310NotificationgvariableOpticalAttenuatorFailureHighcurrentVariable Optical Attenuator Failure High
1.3.6.1.4.1.3607.2.20.0.13320NotificationglaserBiasDegradecurrentLaser Bias Degrade
1.3.6.1.4.1.3607.2.20.0.13330NotificationglaserBiasFailurecurrentaser Bias Failure
1.3.6.1.4.1.3607.2.20.0.13340NotificationglaserTemperatureDegradecurrentLaser Temperature Degrade
1.3.6.1.4.1.3607.2.20.0.13350NotificationgopticalAmplifierGainDegradeLowcurrentOptical Amplifier Gain Degrade Low
1.3.6.1.4.1.3607.2.20.0.13360NotificationgopticalAmplifierGainDegradeHighcurrentOptical Amplifier Gain Degrade High
1.3.6.1.4.1.3607.2.20.0.13370NotificationgopticalAmplifierGainFailureLowcurrentOptical Amplifier Gain Failure Low
1.3.6.1.4.1.3607.2.20.0.13380NotificationgopticalAmplifierGainFailureHighcurrentOptical Amplifier Gain Failure High
1.3.6.1.4.1.3607.2.20.0.13390NotificationgopticalChannelConnectionFailurecurrentOptical Channel connection failure
1.3.6.1.4.1.3607.2.20.0.13395NotificationgopticalChannelIncompletecurrentOptical Channel Incomplete
1.3.6.1.4.1.3607.2.20.0.13400NotificationgopticalChannelActivationFailurecurrentOptical Channel activation failure
1.3.6.1.4.1.3607.2.20.0.13410NotificationglaserAutoPowerReductioncurrentLaser Auto Power Reduction
1.3.6.1.4.1.3607.2.20.0.13420NotificationgcaseTemperatureDegradecurrentCase Temperature Degrade
1.3.6.1.4.1.3607.2.20.0.13430NotificationgfiberTemperatureDegradecurrentFiber Temperature Degrade
1.3.6.1.4.1.3607.2.20.0.13440NotificationgshutterOpencurrentShutter Failure
1.3.6.1.4.1.3607.2.20.0.13450NotificationgawgTemperatureDegradecurrentAWG Temperature Degrade
1.3.6.1.4.1.3607.2.20.0.13460NotificationgawgTemperatureFailurecurrentAWG Temperature Failure
1.3.6.1.4.1.3607.2.20.0.13470NotificationgawgOverTemperaturecurrentAWG Over-Temperature
1.3.6.1.4.1.3607.2.20.0.13480NotificationgopticalAmplifierInitializationcurrentOptical Amplifier Initialization
1.3.6.1.4.1.3607.2.20.0.13490NotificationgawgWarmUpcurrentAWG Warm Up
1.3.6.1.4.1.3607.2.20.0.13510NotificationgincSiglosscurrentIncoming Signal Loss on Fibre Channel Interface
1.3.6.1.4.1.3607.2.20.0.13515NotificationgincSynclosscurrentIncoming Synchronization Loss on Fibre Channel Interface
1.3.6.1.4.1.3607.2.20.0.13520NotificationgincGfpOutOfFramecurrentOut Of Frame Detected by GFP Receiver
1.3.6.1.4.1.3607.2.20.0.13525NotificationgincGfpSigLosscurrentClient Signal Loss Frames Detected by GFP Receiver
1.3.6.1.4.1.3607.2.20.0.13530NotificationgincGfpSyncLosscurrentClient Sychronization Loss Frames Detected by GFP Receiver
1.3.6.1.4.1.3607.5.10IdentitycerentConformancecurrentThis node is created for compliance. Has objects as required by the RFCs
1.3.6.1.4.1.3607.5.10.10IdentitycerentGenericGroupscurrentAll the objects and events are grouped under this for conformance
1.3.6.1.4.1.3607.5.10.10.10GroupnodeGenericGroupcurrentThe group for node related objects
1.3.6.1.4.1.3607.5.10.10.20GroupalarmGenericGroupcurrentThe group for node related objects
1.3.6.1.4.1.3607.5.10.10.30GroupeventGenericGroupcurrentThe generic notifications for Cisco ONS network device, ONS 15327, 15310
1.3.6.1.4.1.3607.5.10.10.40GroupcerentGenericCommonGroupcurrentThe objects related to traps dispatch
1.3.6.1.4.1.3607.5.10.10.50GroupcerentThresholdGroupcurrentThe objects for storing all the current alarms
1.3.6.1.4.1.3607.5.10.10.60GroupeventGenericDeprecatedGroupdeprecatedThe deprecated notifications for Cisco ONS network devices
1.3.6.1.4.1.3607.5.10.10.70GroupreportedAlarmGenericGroupcurrentThe group for reported alarm objects
1.3.6.1.4.1.3607.5.10.20IdentitycerentCompliancecurrentThe compliance statements for Cisco ONS 15327, 15310.
1.3.6.1.4.1.3607.5.10.20.10CompliancecerentGenericBasicCompliancecurrentThe basic implementation requirements for Cisco ONS network device, ONS 15327, 15310
Type Definitions
NameSyntaxStatusDescription
CerentGenericAlarmTypeINTEGER { galarmUnknown ( 1 ), galarmCutoffIsInManualMode ( 10 ), gfailureDetectedExternalToTheNE ( 20 ), gexternalError ( 30 ), gexcessiveSwitching ( 40 ), gsdccTerminationFailure ( 50 ), gincomingFailureCondition ( 60 ), galarmIndicationSignal ( 70 ), galarmIndicationSignalLine ( 80 ), galarmIndicationSignalPath ( 90 ), galarmIndicationSignalVT ( 100 ), gapsChannelFailure ( 110 ), gchannelByteFailureAPS ( 120 ), gchannelProtectionSwitchingChannelMatchFailureAPS ( 130 ), gchannelAutomaticProtectionSwitchModeMismatchAPS ( 140 ), gfarEndProtectionLineFailure ( 150 ), ginconsistentAPSCode ( 160 ), gimproperAPSCode ( 170 ), gnodeIdMismatch ( 180 ), gchannelDefaultKAPS ( 190 ), gconnectionLoss ( 200 ), gbipolarViolation ( 210 ), gcarrierLossOnTheLAN ( 220 ), gconcatenationErrorSTS ( 230 ), gexcessCollisionsOnTheLAN ( 240 ), gfacilityFailure ( 250 ), gfarEndAIS ( 260 ), gfarEndMultipleDS1LOSDetectedOnDS3 ( 270 ), gfarEndDS1EqptFailNonServiceAffecting ( 280 ), gfarEndDS1EqptFailServiceAffecting ( 290 ), gfarEndSingleDS1LOS ( 300 ), gfarEndDS3EqptFailNonServiceAffecting ( 310 ), gfarEndDS3EqptFailServiceAffecting ( 320 ), gfarEndCommonEquipmentFailureNonServiceAffecting ( 330 ), gfarEndIDLE ( 340 ), gfarEndLOS ( 350 ), gfarEndLOF ( 360 ), gfarEndBlockError ( 370 ), gds3IdleCondition ( 380 ), glossOfFrame ( 390 ), glossOfPointer ( 400 ), glossOfPointerPath ( 410 ), glossOfPointerVT ( 420 ), glossOfSignal ( 430 ), goutOfFrame ( 440 ), gpathSelectorFailure ( 450 ), gremoteAlarmIndication ( 460 ), gremoteFailureIndication ( 470 ), gremoteFailureIndicationLine ( 480 ), gremoteFailureIndicationPath ( 490 ), gremoteFailureIndicationVT ( 500 ), gsignalDegrade ( 510 ), gseverelyErroredFrame ( 520 ), gsignalFailure ( 530 ), gsignalLabelMismatchFailure ( 540 ), gpayloadDefectIndication ( 550 ), gpayloadDefectIndicationPath ( 560 ), gpayloadLabelMismatchPath ( 570 ), gsignalLabelMismatchFailurePayloadLabelMismatchVT ( 580 ), gunequippedPath ( 590 ), gsignalLabelMismatchFailureUnequippedVT ( 600 ), glossOfSynchronization ( 610 ), goutOfSynchronization ( 620 ), gprimarySynchronizationReferenceFailure ( 630 ), gsecondarySynchronizationReferenceFailure ( 640 ), gthirdSynchronizationReferenceFailure ( 650 ), gfourthSynchronizationReferenceFailure ( 660 ), gfifthSynchronizationReferenceFailure ( 670 ), gsixthSynchronizationReferenceFailure ( 680 ), gfailedToReceiveSynchronizationStatusMessage ( 690 ), gsynchronizationStatusMessagesAreDisabledOnThisInterface ( 700 ), gstratum1PrimaryReferenceSourceTraceable ( 710 ), gsynchronizedTraceabilityUnknown ( 720 ), gstratum2Traceable ( 730 ), gtransitNodeClockTraceable ( 740 ), gstratum3ETraceable ( 750 ), gstratum3Traceable ( 760 ), gsonetMinimumClockTraceable ( 770 ), gstratum4Traceable ( 780 ), gdoNotUseForSynchronization ( 790 ), greservedForNetworkSynchronizationUse ( 800 ), goutgoingFailureCondition ( 810 ), gremoteDefectIndicationLine ( 820 ), gremoteDefectIndicationPath ( 830 ), gfreeRunningSynchronizationMode ( 840 ), gholdoverSynchronizationMode ( 850 ), gfastStartSynchronizationMode ( 860 ), ginternalFault ( 870 ), ginternalError ( 880 ), ginternalMessageError ( 890 ), gmismatchOfEquipmentAndAttributes ( 900 ), gwatchdogTimerTimeout ( 910 ), gsoftwareFaultOrFailure ( 920 ), gsoftwareFaultDataIntegrityFault ( 930 ), gprogramFailure ( 940 ), gcontrolEquipmentFailure ( 950 ), gprimaryNonVolatileBackupMemoryFailure ( 960 ), gsecondaryNonVolatileBackupMemoryFailure ( 970 ), gcontrolBusFailure ( 980 ), gcontrolBus1Failure ( 990 ), gcontrolBus2Failure ( 1000 ), gtccAToShelfSlot1DROP1CommunicationFailure ( 1010 ), gtccAToShelfSlot2DROP2CommunicationFailure ( 1020 ), gtccAToShelfSlot3DROP3CommunicationFailure ( 1030 ), gtccAToShelfSlot4DROP4CommunicationFailure ( 1040 ), gtccAToShelfSlot5TRUNK1CommunicationFailure ( 1050 ), gtccAToShelfSlot6TRUNK2CommunicationFailure ( 1060 ), gtccAToShelfSlot7TCCACommunicationFailure ( 1070 ), gtccAToShelfSlot8XCONACommunicationFailure ( 1080 ), gtccAToShelfSlot9AICCommunicationFailure ( 1090 ), gtccAToShelfSlot10XCONBCommunicationFailure ( 1100 ), gtccAToShelfSlot11TCCBCommunicationFailure ( 1110 ), gtccAToShelfSlot12TRUNK3CommunicationFailure ( 1120 ), gtccAToShelfSlot13TRUNK4CommunicationFailure ( 1130 ), gtccAToShelfSlot14DROP5CommunicationFailure ( 1140 ), gtccAToShelfSlot15DROP6CommunicationFailure ( 1150 ), gtccAToShelfSlot16DROP7CommunicationFailure ( 1160 ), gtccAToShelfSlot17DROP8CommunicationFailure ( 1170 ), gtccAToDCCAProcessorCommunicationFailure ( 1180 ), gtccBToShelfSlot1DROP1CommunicationFailure ( 1190 ), gtccBToShelfSlot2DROP2CommunicationFailure ( 1200 ), gtccBToShelfSlot3DROP3CommunicationFailure ( 1210 ), gtccBToShelfSlot4DROP4CommunicationFailure ( 1220 ), gtccBToShelfSlot5TRUNK1CommunicationFailure ( 1230 ), gtccBToShelfSlot6TRUNK2CommunicationFailure ( 1240 ), gtccBToShelfSlot7TCCACommunicationFailure ( 1250 ), gtccBToShelfSlot8XCONACommunicationFailure ( 1260 ), gtccBToShelfSlot9AICCommunicationFailure ( 1270 ), gtccBToShelfSlot10XCONBCommunicationFailure ( 1280 ), gtccBToShelfSlot11TCCBCommunicationFailure ( 1290 ), gtccBToShelfSlot12TRUNK3CommunicationFailure ( 1300 ), gtccBToShelfSlot13TRUNK4CommunicationFailure ( 1310 ), gtccBToShelfSlot14DROP5CommunicationFailure ( 1320 ), gtccBToShelfSlot15DROP6CommunicationFailure ( 1330 ), gtccBToShelfSlot16DROP7CommunicationFailure ( 1340 ), gtccBToShelfSlot17DROP8CommunicationFailure ( 1350 ), gtccBToDCCBProcessorCommunicationFailure ( 1360 ), gcontrolEquipmentControlCommunicationsEquipmentFailure ( 1370 ), gcontrolProcessorFailure ( 1380 ), gworkingMemoryFailure ( 1390 ), ginterconnectionEquipmentFailure ( 1400 ), gpayloadBusFailureToIOSlot1XCONSlot8 ( 1410 ), gpayloadBusFailureToIOSlot2XCONSlot8 ( 1420 ), gpayloadBusFailureToIOSlot3XCONSlot8 ( 1430 ), gpayloadBusFailureToIOSlot4XCONSlot8 ( 1440 ), gpayloadBusFailureToIOSlot5XCONSlot8 ( 1450 ), gpayloadBusFailureToIOSlot6XCONSlot8 ( 1460 ), gpayloadBusFailureToIOSlot12XCONSlot8 ( 1470 ), gpayloadBusFailureToIOSlot13XCONSlot8 ( 1480 ), gpayloadBusFailureToIOSlot14XCONSlot8 ( 1490 ), gpayloadBusFailureToIOSlot15XCONSlot8 ( 1500 ), gpayloadBusFailureToIOSlot16XCONSlot8 ( 1510 ), gpayloadBusFailureToIOSlot17XCONSlot8 ( 1520 ), gpayloadBusFailureToIOSlot1XCONSlot10 ( 1530 ), gpayloadBusFailureToIOSlot2XCONSlot10 ( 1540 ), gpayloadBusFailureToIOSlot3XCONSlot10 ( 1550 ), gpayloadBusFailureToIOSlot4XCONSlot10 ( 1560 ), gpayloadBusFailureToIOSlot5XCONSlot10 ( 1570 ), gpayloadBusFailureToIOSlot6XCONSlot10 ( 1580 ), gpayloadBusFailureToIOSlot12XCONSlot10 ( 1590 ), gpayloadBusFailureToIOSlot13XCONSlot10 ( 1600 ), gpayloadBusFailureToIOSlot14XCONSlot10 ( 1610 ), gpayloadBusFailureToIOSlot15XCONSlot10 ( 1620 ), gpayloadBusFailureToIOSlot16XCONSlot10 ( 1630 ), gpayloadBusFailureToIOSlot17XCONSlot10 ( 1640 ), gtimeSlotInterchangeEquipmentFailure ( 1650 ), gequipmentFailure ( 1660 ), ghighTemperature ( 1670 ), ginvalidMACAddress ( 1680 ), gboardFailure ( 1690 ), gdiagnosticFailure ( 1700 ), gmediumAccessControlFailure ( 1710 ), gfacilityTerminationEquipmentFailure ( 1720 ), gautomaticLaserShutoffDueToHighTemperature ( 1730 ), gfailureToReleaseFromProtection ( 1740 ), greceiverFailure ( 1750 ), gtransmitFailure ( 1760 ), gfacilityTerminationEquipmentReceiverMissing ( 1770 ), gfacilityTerminationEquipmentTransmitterMissing ( 1780 ), gfailureToSwitchToProtection ( 1790 ), gfailureToSwitchToProtectionRing ( 1800 ), gfailureToSwitchToProtectionSpan ( 1810 ), gfailureToSwitchToProtectionPath ( 1820 ), gfanFailure ( 1830 ), gequipmentUnitPlugIn ( 1840 ), gnePowerFailureAtConnector ( 1850 ), gfuseAlarm ( 1860 ), gsynchronizationUnitFailure ( 1870 ), gsynchronizationSwitchingEquipmentFailure ( 1880 ), gequipmentUnitUnplugged ( 1890 ), gloopback ( 1900 ), gds1LoopbackDueToFEACCommand ( 1910 ), gloopbackCommandSentToFarEndDS1 ( 1920 ), gds3LoopbackDueToFEACCommand ( 1930 ), gds3LoopbackCommandSentToFarEnd ( 1940 ), gds2LoopbackDueToFarEndCommand ( 1950 ), gds2LoopbackCommandSentToFarEnd ( 1960 ), gfacilityLoopback ( 1970 ), gnetworkLoopback ( 1980 ), gterminalLoopback ( 1990 ), gmanuallyCausedAbnormalCondition ( 2000 ), gethernetBridgeIsNewRootOfSpanningTree ( 2010 ), gethernetBridgeTopologyChange ( 2020 ), gnormalCondition ( 2030 ), gembeddedOperationsChannelFailureLinkDown ( 2040 ), gpeerStateMismatch ( 2050 ), gproceduralError ( 2060 ), gimproperRemoval ( 2070 ), gduplicateNodeID ( 2080 ), gblsrOutOfSync ( 2090 ), gblsrMultiNodeTableUpdateCompleted ( 2100 ), gprotectionUnitNotAvailable ( 2110 ), gperformanceMonitorThresholdCrossingAlert ( 2120 ), gprotectionSwitch ( 2130 ), grecoveryOrServiceProtectionActionHasBeenInitiated ( 2140 ), gautomaticSystemReset ( 2150 ), gautomaticUPSRSwitchCausedByAIS ( 2160 ), gautomaticUPSRSwitchCausedByLOP ( 2170 ), gautomaticUPSRSwitchCausedByUNEQ ( 2180 ), gautomaticUPSRSwitchCausedByPDI ( 2190 ), gautomaticUPSRSwitchCausedBySFBER ( 2200 ), gautomaticUPSRSwitchCausedBySDBER ( 2210 ), gcoldRestart ( 2220 ), gforcedSwitchBackToWorking( 2230 ), gforcedSwitchBackToWorkingRing ( 2240 ), gforcedSwitchBackToWorkingSpan ( 2250 ), gforcedSwitchToProtection ( 2260 ), gforcedSwitchToProtectionRing ( 2270 ), gforcedSwitchToProtectionSpan ( 2280 ), gworkingFacilityOrEquipmentForcedToSwitchToProtectionPath( 2290 ), ginitializationInitiated ( 2300 ), glockoutOfProtection ( 2310 ), glockoutOfProtectionRing ( 2320 ), glockoutOfProtectionSpan ( 2330 ), glockoutOfProtectionPath ( 2340 ), glockoutOfWorking ( 2350 ), glockoutOfWorkingRing ( 2360 ), glockoutOfWorkingSpan ( 2370 ), gmanualSystemReset ( 2380 ), gmanualSwitchToInternalClock ( 2390 ), gmanualSwitchToPrimaryReference ( 2400 ), gmanualSwitchToSecondReference ( 2410 ), gmanualSwitchToThirdReference ( 2420 ), gmanualSwitchToFourthReference ( 2430 ), gmanualSwitchToFifthReference ( 2440 ), gmanualSwitchToSixthReference ( 2450 ), gmanualSwitchBackToWorking ( 2460 ), gmanualSwitchBackToWorkingRing ( 2470 ), gmanualSwitchBackToWorkingSpan ( 2480 ), gmanualSwitchToProtection ( 2490 ), gmanualSwitchToProtectionRing ( 2500 ), gmanualSwitchToProtectionSpan ( 2510 ), gmanualSwitchOfWorkingFacilityOrEquipmentToProtectionPath ( 2520 ), gpowerfailRestart ( 2530 ), gringIsSquelchingTraffic ( 2540 ), gsoftwareDownloadInProgress ( 2550 ), gswitchToInternalClock ( 2560 ), gswitchToPrimaryReference ( 2570 ), gswitchToSecondReference ( 2580 ), gswitchToThirdReference ( 2590 ), gswitchToFourthReference ( 2600 ), gswitchToFifthReference ( 2610 ), gswitchToSixthReference ( 2620 ), gsystemReboot ( 2630 ), gswitchedBackToWorking ( 2640 ), gswitchedToProtection ( 2650 ), gwarmRestart ( 2660 ), gringIsInWaitToRestoreState ( 2670 ), gmanualSwitchRequest ( 2680 ), gforcedSwitchRequest ( 2690 ), glockoutSwitchRequest ( 2700 ), grmonHistoriesAndAlarmsResetReboot ( 2710 ), grmonThresholdCrossingAlarm ( 2720 ), galarmsSuppressedByUserCommand ( 2730 ), galarmsSuppressedForMaintenance ( 2740 ), gswitchingMatrixModuleFailure ( 2750 ), glanConnectionPolarityReversed ( 2760 ), gautonomousPMReportMessageInhibited ( 2780 ), gioSlotToXCONCommunicationFailure ( 2790 ), gstsPathTraceIdentifierMismatch ( 2800 ), gnePowerFailureAtConnectorA ( 2810 ), gnePowerFailureAtConnectorB ( 2820 ), gfreeMemoryOnCardVeryLow ( 2830 ), gfreeMemoryOnCardNearZero ( 2840 ), gexerciseRequestOnRing ( 2850 ), gexerciseRequestOnSpan ( 2860 ), gsquelchingPath ( 2870 ), gextraTrafficPreempted ( 2880 ), gfarEndLockoutOfWorkingRing ( 2890 ), gfarEndLockoutOfWorkingSpan ( 2900 ), gfarEndLockoutOfProtectionRing ( 2910 ), gfarEndLockoutOfProtectionAllSpans ( 2920 ), gfarEndWorkingFacilityForcedToSwitchToProtectionRing ( 2930 ), gfarEndWorkingFacilityForcedToSwitchToProtectionSpan ( 2940 ), gfarEndManualSwitchOfWorkingFacilityToProtectionRing ( 2950 ), gfarEndManualSwitchOfWorkingFacilityToProtectionSpan ( 2960 ), gfarEndExercisingRing ( 2970 ), gfarEndExercisingSpan ( 2980 ), gfarEndBERThresholdPassedForSignalFailureRing ( 2990 ), gfarEndBERThresholdPassedForSignalFailureSpan ( 3000 ), gfarEndBERThresholdPassedForSignalDegradeRing ( 3010 ), gfarEndBERThresholdPassedForSignalDegradeSpan ( 3020 ), gapsChannelFarEndProtectionLineSignalDegrade ( 3030 ), gringSwitchIsActiveOnTheEastSide ( 3040 ), gringSwitchIsActiveOnTheWestSide ( 3050 ), gspanSwitchIsActiveOnTheEastSide ( 3060 ), gspanSwitchIsActiveOnTheWestSide ( 3070 ), guniDirectionalFullPassThroughIsActive ( 3080 ), gbiDirectionalFullPassThroughIsActive ( 3090 ), gkBytesPassThroughIsActive ( 3100 ), gringIsSegmented ( 3110 ), gringTopologyIsUnderConstruction ( 3120 ), glockoutOfProtectionAllSpans ( 3130 ), gfarEndOfFiberIsProvisionedWithDifferentRingID ( 3140 ), gbothEndsOfFiberProvisionedAsEastOrBothAsWest ( 3150 ), gsecurityInvalidLoginUsernameSeeAuditTrail ( 3160 ), gautonomousMessagesInhibited ( 3170 ), gtrafficStormOnLANLANTemporarilyDisabled( 3180 ), greptdbchgMessagesInhibited ( 3190 ), gsecurityUserIDHasExpired ( 3200 ), gpartialFanFailure ( 3210 ), gforcedSwitchRequestOnRing ( 3220 ), gforcedSwitchRequestOnSpan ( 3230 ), glockoutSwitchRequestOnRing ( 3240 ), glockoutSwitchRequestOnSpan ( 3250 ), gmanualSwitchRequestOnRing ( 3260 ), gmanualSwitchRequestOnSpan ( 3270 ), gcommunicationFailurePeerToPeerSlotControlBusA ( 3280 ), gcommunicationFailurePeerToPeerSlotControlBusB ( 3290 ), gcontrollerAToShelfSlotCommunicationFailure ( 3300 ), gcontrollerBToShelfSlotCommunicationFailure ( 3310 ), ginterconnectionEquipmentFailureWorkingPayloadBus ( 3320 ), ginterconnectionEquipmentFailureProtectPayloadBus ( 3330 ), ginhibitSwitchToProtectRequestOnEquipment ( 3340 ), ginhibitSwitchToWorkingRequestOnEquipment ( 3350 ), gberThresholdExceededForSignalDegradeLine ( 3360 ), gberThresholdExceededForSignalDegradePath ( 3370 ), gberThresholdExceededForSignalFailureLine ( 3380 ), gberThresholdExceededForSignalFailurePath ( 3390 ), gexercisingRingSuccessfully ( 3400 ), gexercisingSpanSuccessfully ( 3410 ), gspanIsInWaitToRestoreState ( 3420 ), gexerciseRequestOnRingFailed ( 3430 ), gexerciseRequestOnSpanFailed ( 3440 ), gfarEndLockoutOfProtectionSpan ( 3450 ), gmanufacturingDataMemoryEEPROMFailure ( 3460 ), greplaceableEquipmentOrUnitIsMissing ( 3470 ), gsoftwareDownloadFailed ( 3480 ), gextraTrafficPCADropped ( 3490 ), getherTxOversubscribed ( 3500 ), getherRxOverSubscribed ( 3510 ), getherTxExcessFlowCtrl ( 3520 ), getherRxExcessFlowCtrl ( 3530 ), gtransportLayerFailure ( 3540 ), getherTxUnderrun ( 3550 ), gsynchronizationReferenceFrequencyOutOfBounds ( 3560 ), gntpOrSntpHostFailure ( 3570 ), gpeerCardNotResponding ( 3580 ), galarmsAndEventsSuppressedForThisObject ( 3590 ), gds3FrameFormatMismatch ( 3600 ), gwaitToRestore ( 3610 ), gextremeHighVoltBatteryA ( 3620 ), gextremeLowVoltBatteryA ( 3630 ), gextremeHighVoltBatteryB ( 3640 ), gextremeLowVoltBatteryB ( 3650 ), giosConfigCopyFailed ( 3660 ), giosConfigCopyInProgress ( 3670 ), giosConfigCopySuccess ( 3680 ), gsignalingUnableToSetupCircuit ( 3710 ), gerrorInStartupConfig ( 3712 ), gnoStartupConfig ( 3714 ), gneedToSaveRunningConfig ( 3716 ), ginvalidAlarm ( 3718 ), grsvpHelloFSMToNeighborDown ( 3720 ), gsecurityInvalidLoginUsername ( 3722 ), gdatabaseBackupFailed ( 3724 ), gdatabaseRestoreFailed ( 3726 ), glmpHelloFSMToControlChannelDown ( 3730 ), glmpNeighborDiscoveryHasFailed ( 3740 ), gunauthorizedIncomingSignalingRequest ( 3750 ), gauditLog80PercentFull ( 3760 ), gmoduleCommunicationFailure ( 3762 ), gauditLog100PercentFullOldestRecordsWillBeLost ( 3764 ), gstandbyDatabaseOutOfSync ( 3766 ), gredundantPowerCapabilityLost ( 3768 ), gforcedSwitchToPrimaryReference ( 3770 ), gforcedSwitchToSecondReference ( 3780 ), gforcedSwitchToThirdReference ( 3790 ), gforcedSwitchToInternalClock ( 3800 ), gindustrialHighTemperature ( 3805 ), gimproperMatrixEquipmentInserted ( 3810 ), geqptProblemOnCarrierOrPIM ( 3820 ), geqptProblemOnPIMOrPPM ( 3830 ), gtimSectionTraceIdentifierMismatchFailure ( 4000 ), gaisMultiplexSectionAlarmIndicationSignal ( 4010 ), grdiMultiplexSectionRemoteDefectOrAlarmIndication( 4020 ), gtimHighOrderTraceIdentifierMismatchFailure ( 4030 ), gaisAdministrationUnitAlarmIndicationSignal ( 4040 ), glopAdministrationUnitLossOfPointer ( 4050 ), gslmfUnequippedHighOrderPathUnequipped ( 4060 ), gslmfPLMHighOrderPathLabelMismatch ( 4070 ), grdiHighOrderRemoteDefectOrAlarmIndication ( 4080 ), glopTributaryUnitLossOfPointer ( 4090 ), gaisTributaryUnitAlarmIndicationSignal ( 4100 ), gslmfUnequippedLowOrderPathUnequipped ( 4110 ), gslmfPLMLowOrderPathLabelMismatch ( 4120 ), gtimLowOrderTraceIdentifierMismatchFailure ( 4130 ), grfiLowOrderRemoteFailureOrAlarmIndication ( 4140 ), gg811PrimaryReferenceClockTraceable ( 4150 ), gg812TransitNodeClockTraceable ( 4160 ), gg812LocalNodeClockTraceable ( 4170 ), gg813SynchronousEquipmentTimingSourceTraceable ( 4180 ), ge1LoopbackDueToFEACCommand ( 4190 ), ge1LoopbackCommandSentToFarEnd ( 4200 ), ge3LoopbackDueToFEACCommand ( 4210 ), gfarEndMultipleE1LOSDetectedOnE3 ( 4220 ), gfarEndE1EqptFailNonServiceAffecting ( 4230 ), gfarEndE1EqptFailServiceAffecting ( 4240 ), gfarEndSingleE1LOS ( 4250 ), gfarEndE3EqptFailServiceAffecting ( 4260 ), ge3LoopbackCommandSentToFarEnd ( 4270 ), gfarEndE3EqptFailNonServiceAffecting ( 4280 ), glowVoltBatteryA ( 4290 ), ghighVoltBatteryA ( 4300 ), glowVoltBatteryB ( 4310 ), ghighVoltBatteryB ( 4320 ), gmsspRingOutOfSync ( 4330 ), gmsspMultiNodeTableUpdateCompleted ( 4340 ), gautomaticSNCPSwitchCausedByAIS ( 4350 ), gautomaticSNCPSwitchCausedByLOP ( 4360 ), gautomaticSNCPSwitchCausedByUNEQ ( 4370 ), gautomaticSNCPSwitchCausedByPDI ( 4380 ), gautomaticSNCPSwitchCausedBySFBER ( 4390 ), gautomaticSNCPSwitchCausedBySDBER ( 4400 ), gstmConcatenationError ( 4410 ), ge3IdleCondition ( 4420 ), gchannelMSSPInconsistentAPSCode ( 4430 ), gchannelMSSPImproperAPSCodeAPS ( 4440 ), gchannelMSSPNodeIdMismatchAPS ( 4450 ), gchannelMSSPDefaultKAPS ( 4460 ), gchannelMSSPConnectionLossAPS ( 4470 ), gminimumClockTraceableSDH ( 4480 ), glineIsInWaitToRestoreStateSDH ( 4490 ), gberThresholdExceededForSignalDegradeHighOrder ( 4500 ), gberThresholdExceededForSignalFailureHighOrder ( 4510 ), gberThresholdExceededForSignalDegradeLowOrder ( 4520 ), gberThresholdExceededForSignalFailureLowOrder ( 4530 ), gfailureToSwitchToProtectionHighOrderPath ( 4540 ), gfailureToSwitchToProtectionLowOrderPath ( 4550 ), glofAdministrationUnitLossOfMultiFrame ( 4560 ), gsdhSpanIsInWaitToRestoreState ( 4570 ), ga8b10bOutOfSync ( 4755 ), godukPMAlarmIndicationSignal ( 4760 ), gotukAlarmIndicationSignal ( 4765 ), gotukSMBackwardDefectIndication ( 4770 ), gfecUncorrectedWord ( 4780 ), ggccTerminationFailure ( 4785 ), gotukIncomingAlignmentError ( 4790 ), godukLockedDefectPM ( 4795 ), glossOfMultiFrame ( 4800 ), godukOpenConnectionIndication ( 4805 ), gpayloadTypeIdentifierMismatch ( 4810 ), godukTrailTraceIdentifierMismatch ( 4815 ), gotukTrailTraceIdentifierMismatch ( 4820 ), gequipmentHighLaserBias ( 4825 ), gequipmentHighLaserTemp ( 4830 ), gequipmentHighLaserPeltier ( 4835 ), gfacilityHighRxPower ( 4840 ), gequipmentHighTxPower ( 4845 ), gequipmentHighTransceiverVoltage ( 4850 ), gequipmentLowLaserBias ( 4855 ), gequipmentLowLaserTemp ( 4860 ), gequipmentLowLaserPeltier ( 4865 ), gfacilityLowRxPower ( 4870 ), gequipmentLowTxPower ( 4875 ), gequipmentLowTransceiverVoltage ( 4880 ), gequipmentRxLocked ( 4885 ), gequipmentSquelched ( 4890 ), gequipmentTxLocked ( 4895 ), gotukSignalFailure ( 4900 ), godukSignalFailure ( 4905 ), gotukSignalDegrade ( 4910 ), godukSignalDegrade ( 4915 ), gpluggablePortMissing ( 4920 ), gpluggablePortRateMismatch ( 4925 ), gpluggablePortSecurityCodeMismatch ( 4930 ), gtciNotSelected ( 4935 ), gtci1ClockFailure ( 4940 ), godukPMBackwardDefectIndication ( 4945 ), godukTCM1BackwardDefectIndication ( 4950 ), godukTCM2BackwardDefectIndication ( 4955 ), gequipmentHighRxTemperature ( 4960 ), gequipmentLowRxTemperature ( 4965 ), gtci2ClockFailure ( 4970 ), gequipmentWavelengthMismatch ( 4975 ), gdspCommunicationFailure ( 4980 ), gdspFailure ( 4985 ), glaserApproachingEndOfLife ( 5000 ), gcrossconnectLoopback ( 5010 ), gadminLogoutOf …[truncated - parser boundary issue, please report]currentThis TC is used by the NMS to map the alarm type received by the trap and and display the string shown in LHS.
CerentGenericEntityClassINTEGER { unknownEntity ( 1 ), ne ( 10 ), backplane ( 30 ), eqpt ( 50 ), port ( 60 ), ocn ( 70 ), stmn ( 71 ), aip ( 80 ), fanTray ( 90 ), crs ( 100 ), ds3 ( 110 ), almExpPanel ( 120 ), almIfExtnsn ( 130 ), stsMon ( 140 ), vcMonHp ( 141 ), dwdmClient ( 150 ), stsTerm ( 160 ), vcTermHp ( 161 ), dwdmTrunk ( 170 ), dwdmOptics ( 180 ), psSts ( 190 ), rsms ( 200 ), xcSts ( 210 ), bits ( 220 ), dwdmFec ( 230 ), neSynchRef ( 240 ), dwdm8b10b ( 250 ), extSynchRef ( 260 ), dwdmOtn ( 270 ), envAlrm ( 280 ), envCtrl ( 290 ), neRing ( 360 ), ds1 ( 390 ), vtMon ( 410 ), vcMonLp ( 411 ), vtTerm ( 420 ), vcTermLP ( 421 ), fUdc ( 430 ), msUdc ( 440 ), spareSdcc ( 450 ), ucpCircuit ( 480 ), ucpIpcc ( 490 ), ucpNeighbor ( 500 ), ec1 ( 510 ), ps ( 520 ), psVt ( 530 ), e100t ( 540 ), e1000t ( 550 ), etherBridge ( 560 ), e1 ( 600 ), e3 ( 630 ), e4 ( 640 ), stm1E ( 650 ), ds3i ( 660 ), g1000 ( 670 ), ml100t ( 680 ), ml1000 ( 690 ), dwdmSfp ( 700 ), dwdmScl ( 710 ), dwdmTcm1 ( 720 ), dwdmTcm2 ( 730 ), dwdmOcn ( 740 ), dwdmSm ( 750 ), dwdmPm ( 760 ), dwdmTcm ( 770 ), pwr ( 780 ), stsTermVcat ( 790 ), vtTermVcat ( 800 ), vcatGroup ( 810 ), fcmr ( 820 ), entOptics ( 830 ), ce100t ( 840 ), ppm ( 850 ), twor ( 860 ), isc ( 870 ), escon ( 880 ), bic ( 890 ), gfp ( 900 ), gige ( 910 ), pos ( 920 ), cap ( 930 ), dwdmData ( 940 ), logFac ( 950 ), ge ( 960 ), fc ( 970 ), ec1p1 ( 980 ), mlFx ( 990 ), ochTerm ( 1000 ), shelf ( 1010 ), ce1000 ( 1020 ), cemr ( 1030 ), lmp ( 1040 ), lmpControlChannel ( 1050 ), lmpTeLink ( 1060 ), lmpDataLink ( 1070 ), rpr ( 1080 ), ether ( 1090 ), mlmr ( 1100 ), otu ( 1110 ), aots ( 3200 ), ots ( 3210 ), oms ( 3220 ), och ( 3230 ), osc ( 3240 ), ochc ( 3250 ), ib ( 3260 ), chgrp (3270), hdlc ( 3280 ), msISC ( 3290 ), ecu ( 3300 ), lcdFlash ( 3310 ), usb ( 3320 ), fe ( 3330 ), odu0 ( 3350 ), odu1 ( 3360 ) } cerentGenericObjects OBJECT-IDENTITY STATUS current DESCRIPTION "All the generic objects definitions are grouped under this" ::= { cerentGeneric 10 } cerentGenericCommonObjectsGroup OBJECT-IDENTITY STATUS current DESCRIPTION "The group to combine all the Cisco OTBU common objects" ::= { cerentGenericObjects 10 }currentThis is the TC used to find out to which cerentGenericEntityClass an alarm belongs to.