CERENT-OPTICAL-MONITOR-MIB
46 objects
This MIB module defines objects to monitor optical characteristics and set corresponding thresholds, on the optical interfaces in a network element. This module is an adaptation of CISCO-OPTICAL-MONITOR-MIB.
Imported Objects
| CERENT-GLOBAL-REGISTRY | cerentGeneric cerentModules cerentRequirements |
| CERENT-TC | CerentPeriod |
| IF-MIB | ifIndex |
| SNMPv2-CONF | MODULE-COMPLIANCE OBJECT-GROUP |
| SNMPv2-SMI | Integer32 MODULE-IDENTITY OBJECT-TYPE |
| SNMPv2-TC | TEXTUAL-CONVENTION TruthValue |
| OID | Name | Access | Status | Description |
|---|---|---|---|---|
| 1.3.6.1.4.1.3607.1.10.70 | IdentitycerentOpticalMonitorMIB | This MIB module defines objects to monitor optical characteristics and set corresponding thresholds, on the optical interfaces in a network element. This modul… | ||
| 1.3.6.1.4.1.3607.2.30 | NodecerentOpticalMonitorMIBObjects | |||
| 1.3.6.1.4.1.3607.2.30.1 | NodecerentOpticalMonGroup | |||
| 1.3.6.1.4.1.3607.2.30.1.1 | TablecOpticalMonTable | not-accessible | current | This table provides objects to monitor optical parameters in a network element. It also provides objects for setting high and low threshold levels, with config… |
| 1.3.6.1.4.1.3607.2.30.1.1.1 | RowcOpticalMonEntry | not-accessible | current | An entry in the cOpticalMonTable provides objects to monitor an optical parameter and set threshold levels on that parameter, at an optical interface. Note tha… |
| 1.3.6.1.4.1.3607.2.30.1.1.1.1 | ColumncOpticalMonDirection | not-accessible | current | This object is an index into the cOpticalMonTable and indicates the direction monitored for the optical interface, in this entry. |
| 1.3.6.1.4.1.3607.2.30.1.1.1.2 | ColumncOpticalMonParameterType | not-accessible | current | This object is an index into the cOpticalMonTable and specifies the optical parameter that is being monitored, in this entry. |
| 1.3.6.1.4.1.3607.2.30.1.1.1.3 | ColumncOpticalParameterValue | read-only | current | This object gives the value measured for the particular optical parameter specified by the cOpticalMonParameterType object. |
| 1.3.6.1.4.1.3607.2.30.1.1.1.4 | ColumncOpticalParamHighAlarmThresh | read-write | current | This object is used to set a high alarm threshold on the optical parameter being monitored. If the measured value of the parameter,is greater than the value co… |
| 1.3.6.1.4.1.3607.2.30.1.1.1.5 | ColumncOpticalParamHighWarning15MinThresh | read-write | current | This object is used to set a high warning 15 minute threshold on the optical parameter being monitored. If the measured value of the parameter,is greater than … |
| 1.3.6.1.4.1.3607.2.30.1.1.1.6 | ColumncOpticalParamHighWarning1DayThresh | read-write | current | This object is used to set a high warning 1 day threshold on the optical parameter being monitored. If the measured value of the parameter,is greater than the … |
| 1.3.6.1.4.1.3607.2.30.1.1.1.7 | ColumncOpticalParamLowAlarmThresh | read-write | current | This object is used to set a low alarm threshold on the optical parameter being monitored. If the measured value of the parameter,goes lower than the value con… |
| 1.3.6.1.4.1.3607.2.30.1.1.1.8 | ColumncOpticalParamLowWarning15MinThresh | read-write | current | This object is used to set a low warning 15 minute threshold on the optical parameter being monitored. If the measured value of the parameter,goes lower than t… |
| 1.3.6.1.4.1.3607.2.30.1.1.1.9 | ColumncOpticalParamLowWarning1DayThresh | read-write | current | This object is used to set a low warning 1 day threshold on the optical parameter being monitored. If the measured value of the parameter,goes lower than the v… |
| 1.3.6.1.4.1.3607.2.30.1.1.1.10 | ColumncOpticalParamLowDegradeThresh | read-write | current | This object is used to set a low degrade threshold on the optical parameter being monitored. If the measured value of the parameter,goes lower than the value c… |
| 1.3.6.1.4.1.3607.2.30.1.1.1.11 | ColumncOpticalParamHighDegradeThresh | read-write | current | This object is used to set a high degrade threshold on the optical parameter being monitored. If the measured value of the parameter,goes lower than the value … |
| 1.3.6.1.4.1.3607.2.30.2 | NodecerentOpticalPMGroup | |||
| 1.3.6.1.4.1.3607.2.30.2.1 | TablecOpticalPMCurrentTable | not-accessible | current | This table stores performance monitoring data for the various optical parameters, collected over the current interval. |
| 1.3.6.1.4.1.3607.2.30.2.1.1 | RowcOpticalPMCurrentEntry | not-accessible | current | An entry in the cOpticalPMCurrentTable. It contains performance monitoring data for an optical parameter, collected over the current interval. Note that the se… |
| 1.3.6.1.4.1.3607.2.30.2.1.1.1 | ColumncOpticalPMCurrentDirection | not-accessible | current | This object is an index into the cOpticalPMCurrentTable and indicates the direction monitored for the optical interface, in this entry. |
| 1.3.6.1.4.1.3607.2.30.2.1.1.2 | ColumncOpticalPMCurrentParamType | not-accessible | current | This object is an index into the cOpticalPMCurrentTable and specifies the optical parameter that is being monitored, in this entry. |
| 1.3.6.1.4.1.3607.2.30.2.1.1.3 | ColumncOpticalPMCurrentPeriod | not-accessible | current | This object is an index into the cOpticalPMCurrentTable and indicates whether the optical parameter values given in this entry, are collected over a period of … |
| 1.3.6.1.4.1.3607.2.30.2.1.1.4 | ColumncOpticalPMCurrentMaxParam | read-only | current | This object gives the maximum value measured for the optical parameter, in the current 15 minute or 24 hour interval. |
| 1.3.6.1.4.1.3607.2.30.2.1.1.5 | ColumncOpticalPMCurrentMinParam | read-only | current | This object gives the minimum value measured for the optical parameter, in the current 15 minute or 24 hour interval. |
| 1.3.6.1.4.1.3607.2.30.2.1.1.6 | ColumncOpticalPMCurrentMeanParam | read-only | current | This object gives the average value of the measured optical parameter, in the current 15 minute or 24 hour interval. |
| 1.3.6.1.4.1.3607.2.30.2.2 | TablecOpticalPMIntervalTable | not-accessible | current | This table stores performance monitoring data for the various optical parameters, collected over current and previous intervals. This table can have entries fo… |
| 1.3.6.1.4.1.3607.2.30.2.2.1 | RowcOpticalPMIntervalEntry | not-accessible | current | An entry in the cOpticalPMIntervalTable. It contains performance monitoring data for an optical parameter, collected over current and previous intervals. Note … |
| 1.3.6.1.4.1.3607.2.30.2.2.1.1 | ColumncOpticalPMIntervalDirection | not-accessible | current | This object is an index into the cOpticalPMIntervalTable and indicates the direction monitored for the optical interface, in this entry. |
| 1.3.6.1.4.1.3607.2.30.2.2.1.2 | ColumncOpticalPMIntervalParamType | not-accessible | current | This object is an index into the cOpticalPMIntervalTable and specifies the optical parameter that is being monitored, in this entry. |
| 1.3.6.1.4.1.3607.2.30.2.2.1.3 | ColumncOpticalPMIntervalPeriod | not-accessible | current | This object is an index into the cOpticalPMIntervalTable and indicates whether the optical parameter values given in this entry, are collected over a period of… |
| 1.3.6.1.4.1.3607.2.30.2.2.1.4 | ColumncOpticalPMIntervalNumber | not-accessible | current | This object is an index into the cOpticalPMIntervalTable. It is a number between 1 and 96, which identifies the interval for which the set of optical parameter… |
| 1.3.6.1.4.1.3607.2.30.2.2.1.5 | ColumncOpticalPMIntervalMaxParam | read-only | current | This object gives the maximum value measured for the optical parameter, in a particular 15 minute or 24 hour interval. |
| 1.3.6.1.4.1.3607.2.30.2.2.1.6 | ColumncOpticalPMIntervalMinParam | read-only | current | This object gives the minimum value measured for the optical parameter, in a particular 15 minute or 24 hour interval. |
| 1.3.6.1.4.1.3607.2.30.2.2.1.7 | ColumncOpticalPMIntervalMeanParam | read-only | current | This object gives the average value of the measured optical parameter, in a particular 15 minute or 24 hour interval. |
| 1.3.6.1.4.1.3607.2.30.2.2.1.8 | ColumncOpticalPMIntervalValidData | read-only | current | This variable indicates if the data for this interval is valid. |
| 1.3.6.1.4.1.3607.5.20 | NodecerentOpticalMonitorMIBConformance | |||
| 1.3.6.1.4.1.3607.5.20.1 | NodecerentOpticalMonitorMIBCompliances | |||
| 1.3.6.1.4.1.3607.5.20.1.1 | CompliancecerentOpticalMonitorMIBCompliance | read-only | current | The compliance statement for network elements that monitor optical characteristics and set thresholds on the optical interfaces in a network element. |
| 1.3.6.1.4.1.3607.5.20.2 | NodecerentOpticalMonitorMIBGroups | |||
| 1.3.6.1.4.1.3607.5.20.2.1 | GroupcerentOpticalMIBMonGroup | current | A mandatory object that provides monitoring of optical characteristics. | |
| 1.3.6.1.4.1.3607.5.20.2.2 | GroupcerentOpticalMIBThresholdGroup | current | A collection of objects that support thresholds on optical parameters and provide status information when the thresholds are exceeded or cleared. | |
| 1.3.6.1.4.1.3607.5.20.2.3 | GroupcerentOpticalMIBPMGroup | current | A collection of objects that provide optical performance monitoring data for 15 minute and 24 hour intervals. | |
| 1.3.6.1.4.1.3607.5.20.2.4 | GroupcerentOpticalDwdmNetworkMIBThresholdGroup | current | A collection of objects that support thresholds on optical DWDM Network parameters and provide status information when the thresholds are exceeded or cleared. |
Type Definitions
| Name | Syntax | Status | Description |
|---|---|---|---|
| OpticalIfDirection | INTEGER { receive(1), transmit(2), notApplicable(3) } | current | This value indicates the direction being monitored at the optical interface. |
| OpticalParameterType | INTEGER { power(1), acPower(2), apdTemp(3), laserTemp(4), biasCurrent(5), peltierCurrent(6), xcvrVoltage(7), voa(8), gain(9), oscPower(10), addPower(11) } | current | This value indicates the optical parameter that is being monitored. Valid values are - power (1) : Optical Power (AC + DC). acPower (2) : Optical AC Power. apdTemp (3) : Avalanche Photo Detector Temperature. laserTemp (… |
| OpticalParameterValue | Integer32 ( -1000000..1000000 ) | current | The value of the optical parameter that is being monitored. The range of values varies depending on the type of optical parameter being monitored, as identified by a corresponding object with syntax OpticalParameterType… |