CIENA-CES-TIME-SYNC-MIB
98 objects
This MIB module defines objects and associated notifications for the System Timing feature.
Imported Objects
| CIENA-CES-MODULE-MIB | cienaCesModuleSlotName |
| CIENA-GLOBAL-MIB | cienaGlobalMacAddress cienaGlobalSeverity |
| CIENA-SMI | cienaCesConfig cienaCesNotifications |
| CIENA-TC | CienaGlobalState |
| SNMPv2-SMI | Integer32 MODULE-IDENTITY NOTIFICATION-TYPE OBJECT-TYPE Unsigned32 |
| SNMPv2-TC | DisplayString TEXTUAL-CONVENTION |
| OID | Name | Access | Status | Description |
|---|---|---|---|---|
| 1.3.6.1.4.1.1271.2.1.28 | IdentitycienaCesTimeSyncMIB | This MIB module defines objects and associated notifications for the System Timing feature. | ||
| 1.3.6.1.4.1.1271.2.1.28.1 | NodecienaCesTimeSyncMIBObjects | |||
| 1.3.6.1.4.1.1271.2.1.28.1.1 | NodecienaCesTimeSyncObjects | |||
| 1.3.6.1.4.1.1271.2.1.28.1.1.1 | ScalarcienaCesSyncAdminState | read-only | current | Globally enable/disable Sync |
| 1.3.6.1.4.1.1271.2.1.28.1.1.2 | ScalarcienaCesSyncOptionType | read-only | current | Indication of which set of SSM values being used. Option 1 is for International standard and Option 2 is for North American. |
| 1.3.6.1.4.1.1271.2.1.28.1.1.3 | ScalarcienaCesSyncRevertiveMode | read-only | current | Revertive mode. |
| 1.3.6.1.4.1.1271.2.1.28.1.1.4 | ScalarcienaCesSyncWaitToRestoreTimer | read-only | current | User configured timer for a timing reference source to wait before transitioning from bad to good clock signal. |
| 1.3.6.1.4.1.1271.2.1.28.1.1.5 | TablecienaCesSyncInputProtectionGroupTable | not-accessible | current | A table of protection groups for input timing reference. |
| 1.3.6.1.4.1.1271.2.1.28.1.1.5.1 | RowcienaCesSyncInputProtectionGroupEntry | not-accessible | current | An entry in this table represents information on a protection group for input timing reference |
| 1.3.6.1.4.1.1271.2.1.28.1.1.5.1.1 | ColumncienaCesInputPGEntityId | not-accessible | current | The unique identifier of this input protection group. |
| 1.3.6.1.4.1.1271.2.1.28.1.1.5.1.2 | ColumncienaCesInputPGEntityName | read-only | current | The unique name of this input protection group. |
| 1.3.6.1.4.1.1271.2.1.28.1.1.5.1.3 | ColumncienaCesInputPGPreferredReference | read-only | deprecated | Preferred timing reference source, configured by users. |
| 1.3.6.1.4.1.1271.2.1.28.1.1.5.1.4 | ColumncienaCesInputPGSelectedReference | read-only | current | System selected timing reference source. |
| 1.3.6.1.4.1.1271.2.1.28.1.1.5.1.5 | ColumncienaCesInputPGForcedReference | read-only | current | System was forced to used this timing reference source. |
| 1.3.6.1.4.1.1271.2.1.28.1.1.5.1.6 | ColumncienaCesInputPGThresholdQualityLevel | read-only | current | Specified Quality Level threshold for a reference source being selected. |
| 1.3.6.1.4.1.1271.2.1.28.1.1.5.1.7 | ColumncienaCesInputPGState | read-only | deprecated | Configured state of this protection group. |
| 1.3.6.1.4.1.1271.2.1.28.1.1.5.1.8 | ColumncienaCesInputPGStateDuration | read-only | current | Duration since the system entered current state. |
| 1.3.6.1.4.1.1271.2.1.28.1.1.5.1.9 | ColumncienaCesInputPGReferenceSwitchCount | read-only | current | The number of timing reference switching since the system stared up. |
| 1.3.6.1.4.1.1271.2.1.28.1.1.5.1.10 | ColumncienaCesInputPGOperationalStatus | read-only | current | Operational status of this protection group. |
| 1.3.6.1.4.1.1271.2.1.28.1.1.5.1.11 | ColumncienaCesInputPGTimingType | read-only | current | The timing domain (freq/phase/tod) that this protection group belongs to. |
| 1.3.6.1.4.1.1271.2.1.28.1.1.5.1.12 | ColumncienaCesInputPGOperationalQualityLevel | read-only | current | Operational Quality Level of the protection group. |
| 1.3.6.1.4.1.1271.2.1.28.1.1.6 | TablecienaCesSyncInputProtectionUnitTable | not-accessible | current | A table of protection units for input timing reference. |
| 1.3.6.1.4.1.1271.2.1.28.1.1.6.1 | RowcienaCesSyncInputProtectionUnitEntry | not-accessible | current | An entry in this table represents information on a protection unit for input timing reference. |
| 1.3.6.1.4.1.1271.2.1.28.1.1.6.1.1 | ColumncienaCesInputPUEntityId | not-accessible | current | The unique identifier of this input protection unit. |
| 1.3.6.1.4.1.1271.2.1.28.1.1.6.1.2 | ColumncienaCesInputPUEntityName | read-only | current | The unique name of this input protection unit. |
| 1.3.6.1.4.1.1271.2.1.28.1.1.6.1.3 | ColumncienaCesInputPUPGEntityName | read-only | current | The identifier of the input protection group(s) which this input protection unit belongs to. |
| 1.3.6.1.4.1.1271.2.1.28.1.1.6.1.4 | ColumncienaCesInputPUTimingInterfaceName | read-only | current | The interface name of this input protection unit. |
| 1.3.6.1.4.1.1271.2.1.28.1.1.6.1.5 | ColumncienaCesInputPUTimingInterfaceProtocol | read-only | current | The interface protocol of this input protection unit. |
| 1.3.6.1.4.1.1271.2.1.28.1.1.6.1.6 | ColumncienaCesInputPUUserPriority | read-only | current | The user configured priority of this input protection unit. |
| 1.3.6.1.4.1.1271.2.1.28.1.1.6.1.7 | ColumncienaCesInputPUOperationalQL | read-only | current | Operational clock quality level of this input protection unit. |
| 1.3.6.1.4.1.1271.2.1.28.1.1.6.1.8 | ColumncienaCesInputPUForcedQL | read-only | current | User configured clock quality level that this input protection unit is forced to operate at. |
| 1.3.6.1.4.1.1271.2.1.28.1.1.6.1.9 | ColumncienaCesInputPUReceivedQL | read-only | current | Actual received clock quality level of this input protection unit. |
| 1.3.6.1.4.1.1271.2.1.28.1.1.6.1.10 | ColumncienaCesInputPUSsmEnabled | read-only | current | Enable/disable reading of actual received clock quality level for this input protection unit. |
| 1.3.6.1.4.1.1271.2.1.28.1.1.6.1.11 | ColumncienaCesInputPUOperationalStatus | read-only | current | Operational status of this input protection unit. |
| 1.3.6.1.4.1.1271.2.1.28.1.1.6.1.12 | ColumncienaCesInputPUBITSSignalMode | read-only | current | BITS Signal Mode, set if BITS signal is used as a protection unit. |
| 1.3.6.1.4.1.1271.2.1.28.1.1.6.1.13 | ColumncienaCesInputPUBITSSignalFormat | read-only | current | BITS Signal Format, set if BITS signal is used as a protection unit. |
| 1.3.6.1.4.1.1271.2.1.28.1.1.6.1.14 | ColumncienaCesInputPUBITSSignalEncoding | read-only | current | BITS Signal encoding, set if BITS signal is used as a protection unit. |
| 1.3.6.1.4.1.1271.2.1.28.1.1.6.1.15 | ColumncienaCesInputPUUserOverridePriority | read-only | current | The user configured override-priority of this input protection unit. |
| 1.3.6.1.4.1.1271.2.1.28.1.1.6.1.16 | ColumncienaCesInputPUPTPEncapType | read-only | current | PTP Encapsulation Type, set if a PTP input is used as a protection unit. |
| 1.3.6.1.4.1.1271.2.1.28.1.1.6.1.17 | ColumncienaCesInputPUGPSClockMode | read-only | current | GPS clock mode, set if a GPS input is used as a protection unit. |
| 1.3.6.1.4.1.1271.2.1.28.1.1.6.1.18 | ColumncienaCesInputPUGPSFreqClock | read-only | current | GPS frequency clock, set if a GPS input is used as a protection unit and the cienaCesInputPUGPSClockMode is set to frequency. |
| 1.3.6.1.4.1.1271.2.1.28.1.1.6.1.19 | ColumncienaCesInputPUBITSSignalSsmLocation | read-only | current | BITS Signal Ssm Location, set if BITS signal is used as an input reference. |
| 1.3.6.1.4.1.1271.2.1.28.1.1.7 | TablecienaCesSyncOutputTable | not-accessible | current | A table of output timing references. |
| 1.3.6.1.4.1.1271.2.1.28.1.1.7.1 | RowcienaCesSyncOutputEntry | not-accessible | current | An entry in this table represents information for an output timing reference. |
| 1.3.6.1.4.1.1271.2.1.28.1.1.7.1.1 | ColumncienaCesOutputEntityId | not-accessible | current | The unique identifier of this output reference entity. |
| 1.3.6.1.4.1.1271.2.1.28.1.1.7.1.2 | ColumncienaCesOutputEntityName | read-only | current | The unique name of this output reference entity. |
| 1.3.6.1.4.1.1271.2.1.28.1.1.7.1.3 | ColumncienaCesOutputTimingInterfaceName | read-only | current | The interface name of this output reference. |
| 1.3.6.1.4.1.1271.2.1.28.1.1.7.1.4 | ColumncienaCesOutputTimingInterfaceProtocol | read-only | current | The interface protocol of this output reference. |
| 1.3.6.1.4.1.1271.2.1.28.1.1.7.1.5 | ColumncienaCesOutputOperationalQL | read-only | current | Operational clock quality level of this output reference. |
| 1.3.6.1.4.1.1271.2.1.28.1.1.7.1.6 | ColumncienaCesOutputOperationalStatus | read-only | current | Operational status of this output reference. |
| 1.3.6.1.4.1.1271.2.1.28.1.1.7.1.7 | ColumncienaCesOutputBITSSignalMode | read-only | current | BITS Signal Mode, set if BITS signal is used as an output reference. |
| 1.3.6.1.4.1.1271.2.1.28.1.1.7.1.8 | ColumncienaCesOutputBITSSignalFormat | read-only | current | BITS Signal Format, set if BITS signal is used as an output reference. |
| 1.3.6.1.4.1.1271.2.1.28.1.1.7.1.9 | ColumncienaCesOutputBITSSignalEncoding | read-only | current | BITS Signal encoding, set if BITS signal is used as an output reference. |
| 1.3.6.1.4.1.1271.2.1.28.1.1.7.1.10 | ColumncienaCesOutputBITSSignalLineBuildout | read-only | current | BITS Signal Line Buildout, set if BITS signal is used as an output reference. |
| 1.3.6.1.4.1.1271.2.1.28.1.1.7.1.11 | ColumncienaCesOutputBITSSignalSsmLocation | read-only | current | BITS Signal Ssm Location, set if BITS signal is used as an output reference. |
| 1.3.6.1.4.1.1271.2.1.28.1.1.7.1.12 | ColumncienaCesOutputGPSClockMode | read-only | current | GPS clock mode, set if a GPS signal is used as an output reference. |
| 1.3.6.1.4.1.1271.2.1.28.1.1.7.1.13 | ColumncienaCesOutputGPSFreqClock | read-only | current | GPS frequency clock, set if a GPS signal is used as an output reference and the cienaCesOutputGPSClockMode is set to frequency. |
| 1.3.6.1.4.1.1271.2.1.28.1.1.7.1.14 | ColumncienaCesOutputPTPEncapType | read-only | current | PTP Encapsulation Type, set if a PTP output is used as an output reference. |
| 1.3.6.1.4.1.1271.2.1.28.1.1.8 | NodecienaCesSyncPTPConfig | |||
| 1.3.6.1.4.1.1271.2.1.28.1.1.8.1 | NodecienaCesSyncPTPGlobalConfig | |||
| 1.3.6.1.4.1.1271.2.1.28.1.1.8.1.1 | ScalarcienaCesSyncPTPAddrMode | read-only | current | PTP Address Mode. |
| 1.3.6.1.4.1.1271.2.1.28.1.1.8.1.2 | ScalarcienaCesSyncPTPTagPriority | read-only | current | PTP tag priority |
| 1.3.6.1.4.1.1271.2.1.28.1.1.8.1.3 | ScalarcienaCesSyncPTPProtocolVersion | read-only | current | PTP Protocol Version. |
| 1.3.6.1.4.1.1271.2.1.28.1.1.8.1.4 | ScalarcienaCesSyncPTPProfileVersion | read-only | current | PTP Profile Version. |
| 1.3.6.1.4.1.1271.2.1.28.1.1.8.1.5 | ScalarcienaCesSyncPTPProfileIdentifier | read-only | current | PTP profile identifier address. |
| 1.3.6.1.4.1.1271.2.1.28.1.1.8.1.6 | ScalarcienaCesSyncPTPDomainNumber | read-only | current | PTP domain number. |
| 1.3.6.1.4.1.1271.2.1.28.1.1.8.1.7 | ScalarcienaCesSyncPTPClockType | read-only | current | PTP Clock Type. |
| 1.3.6.1.4.1.1271.2.1.28.1.1.8.1.8 | ScalarcienaCesSyncPTPClockID | read-only | current | PTP clock identifier. |
| 1.3.6.1.4.1.1271.2.1.28.1.1.8.1.9 | ScalarcienaCesSyncPTPDscp | read-only | current | PTP DSCP. |
| 1.3.6.1.4.1.1271.2.1.28.1.1.8.2 | NodecienaCesSyncPTPInputConfig | |||
| 1.3.6.1.4.1.1271.2.1.28.1.1.8.2.1 | ScalarcienaCesSyncPTPInputUnicastReqDuration | read-only | current | PTP input unicast request duration in seconds. |
| 1.3.6.1.4.1.1271.2.1.28.1.1.8.2.2 | ScalarcienaCesSyncPTPInputAnnounceRxLossNum | read-only | current | PTP input announce Rx loss num (announce intervals). |
| 1.3.6.1.4.1.1271.2.1.28.1.1.8.2.3 | ScalarcienaCesSyncPTPInputAnnounceTxRateReq | read-only | current | PTP input announce Tx rate request (pps). |
| 1.3.6.1.4.1.1271.2.1.28.1.1.8.2.4 | ScalarcienaCesSyncPTPInputSyncTxRateReq | read-only | current | PTP input sync Tx rate request (pps). |
| 1.3.6.1.4.1.1271.2.1.28.1.1.8.2.5 | ScalarcienaCesSyncPTPInputDelayReqTxRate | read-only | current | PTP input delay request Tx rate (pps). |
| 1.3.6.1.4.1.1271.2.1.28.1.1.8.3 | NodecienaCesSyncPTPOutputConfig | |||
| 1.3.6.1.4.1.1271.2.1.28.1.1.8.3.1 | ScalarcienaCesSyncPTPOutputMaxSlaveSessions | read-only | current | Maximum number of allowed PTP slave sessions for PTP outputs. |
| 1.3.6.1.4.1.1271.2.1.28.1.1.8.3.2 | ScalarcienaCesSyncPTPOutputTimestampMode | read-only | current | PTP timestamp mode. |
| 1.3.6.1.4.1.1271.2.1.28.1.1.9 | NodecienaCesSyncGPSConfig | |||
| 1.3.6.1.4.1.1271.2.1.28.1.1.9.1 | NodecienaCesSyncGPSOutputConfig | |||
| 1.3.6.1.4.1.1271.2.1.28.1.1.9.1.1 | ScalarcienaCesSyncGPSOutput1ppsPulseWidth | read-only | current | The 1pps pulse width, in microseconds, for GPS output references (applicable to phase). |
| 1.3.6.1.4.1.1271.2.1.28.1.1.10 | ScalarcienaCesSyncHoldoverInterval | read-only | current | User configured interval after which holdover quality level changes. |
| 1.3.6.1.4.1.1271.2.1.28.1.1.11 | ScalarcienaCesSyncModuleSlotClockStatus | accessible-for-notify | current | Lock status of module slot. |
| 1.3.6.1.4.1.1271.2.2.28 | NodecienaCesTimeSyncMIBNotificationPrefix | |||
| 1.3.6.1.4.1.1271.2.2.28.0 | NodecienaCesTimeSyncMIBNotifications | |||
| 1.3.6.1.4.1.1271.2.2.28.0.1 | NotificationcienaCesSyncInputPUStateChangeNotification | current | Sent when a configured timing reference transitions states. | |
| 1.3.6.1.4.1.1271.2.2.28.0.2 | NotificationcienaCesSyncInputProtectionGroupStateChangeNotification | current | Sent when a configured protection-group transitions states. | |
| 1.3.6.1.4.1.1271.2.2.28.0.3 | NotificationcienaCesSyncModuleSlotClockStateChangeNotification | current | Sent when a slot other than the primary CTX experiences a timing state change. Only applicable in SAOS 8.x. |
Type Definitions
| Name | Syntax | Status | Description |
|---|---|---|---|
| SsmStratumLevel | INTEGER { unknown(1), prc(2), ssua(3), ssub(4), sec(5), dnu(6), prs(7), stu(8), st2(9), tnc(10), st3e(11), st3(12), smc(13), st4(14), dus(15), prov(16) } | current | International and North American SSM Values |
| SyncBITSSignalEncoding | INTEGER { unknown(1), b8zs(2), ami(3), hdb3(4) } | current | Encoding method used on T1/E1 BITS signal. |
| SyncBITSSignalFormat | INTEGER { unknown(1), cas(2), cascrc(3), esf(4), fas(5), fascrc(6), sf(7), e1crc(8), e1nocrc(9) } | current | Station Clock BITS signal format. Esf and sf are applied to t1 signal only where as ccs and cas are applied to e1 signal. |
| SyncBITSSignalMode | INTEGER { modeunknown(1), modet1(2), modee1(3), modej1(4), mode2048khz(5), mode64kcc(6), mode6312khz(7) } | current | Station Clock BITS signal mode. |
| SyncGPSFreqClock | INTEGER { unknown(1), clock10mhz(2), clock2048khz(3), clock1544khz(4) } | current | The frequency of the clock for a GPS input/output reference, set when the reference is configured with a clock mode of frequency. |
| SyncInterfaceProtocol | INTEGER { unknown(1), bits(2), synce(3), ptp(4), gps(5), tdm(6) } | current | Interface protocol of an input/output reference. |
| SyncPTPEncapType | INTEGER { unknown(1), udpoveripv4(2), udpoveripv6(3), ieee802dot3(4) } | current | The PTP encapsulation type. |
| SyncPTPRatePps | INTEGER { unknown(1), rate1over16pps(2), rate1over8pps(3), rate1over4pps(4), rate1over2pps(5), rate1pps(6), rate2pps(7), rate4pps(8), rate8pps(9), rate16pps(10), rate32pps(11), rate64pps(12), rate128pps(13) } | current | The PTP rate in pps. |
| SyncRefOperationalStatus | INTEGER { unknown(1), active(2), selected(3), lossofsignal(4), lossofframe(5), alarmindicationsignal(6), hardwarefault(7), hardwarenotconfigured(8), qlbelowthreshold(9), rxtimeout(10), notauthenticated(11), loopbacktx(12), loopbackrx(13), linkflap(14), notready(15), signalfailure(16), warmup(17), qlnotconfigured(18), noconnectivity(19), unsupportedhardware(20), unusable(21) } | current | Operational status of an input/output reference. |
| SyncTimingType | INTEGER { unknown(1), frequency(2), phase(3), tod(4), phaseandtod(5) } | current | The timing domain; frequency, phase or time of day. |