CISCO-6200-MIB
125 objects
This MIB provides CISCO 6200 product information It is structured as following groups: system - not part of indices, defines system, slot and port level scalars.
Imported Objects
| CISCO-SMI | ciscoExperiment |
| SNMPv2-CONF | MODULE-COMPLIANCE OBJECT-GROUP |
| SNMPv2-SMI | Counter32 Gauge32 Integer32 MODULE-IDENTITY OBJECT-TYPE |
| SNMPv2-TC | DateAndTime DisplayString TEXTUAL-CONVENTION |
| OID | Name | Access | Status | Description |
|---|---|---|---|---|
| 1.3.6.1.4.1.9.10.26 | Identitycisco6200MIB | This MIB provides CISCO 6200 product information It is structured as following groups: system - not part of indices, defines system, slot and port level scalar… | ||
| 1.3.6.1.4.1.9.10.26.1 | Nodecisco6200MibObjects | |||
| 1.3.6.1.4.1.9.10.26.1.1 | Nodec62System | |||
| 1.3.6.1.4.1.9.10.26.1.1.1 | ScalarsystemType | read-only | current | This type provides specific details about C6200 system type and what kind of network interface it uses. |
| 1.3.6.1.4.1.9.10.26.1.1.2 | ScalarsystemAlarmLevel | read-only | current | This reflects the alarm level of the C6200 system. It is the aggregation of the slot/port level alarms. Alarm levels supported at the system level are none, mi… |
| 1.3.6.1.4.1.9.10.26.1.1.3 | ScalarsystemAlarmLevelChngCounter | read-only | current | Counter indicating a change in the system alarm level due to change either at the slot or port alarm level. This will be incremented by the system whenever any… |
| 1.3.6.1.4.1.9.10.26.1.1.4 | ScalarsystemReset | read-write | current | This parameter allows user to reboot the system with system configuration from NVRAM (non-volatile memory). It can be used for following purposes: (1) Undo cha… |
| 1.3.6.1.4.1.9.10.26.1.1.5 | ScalarsystemSaveCnfg | read-write | current | This parameter allows user/operator to make system changes permanent. It causes system to write the system configuration on a non-volatile memory (NVRAM). Ther… |
| 1.3.6.1.4.1.9.10.26.1.1.6 | ScalarsystemProvChngCounter | read-only | current | Counter indicating a card or subscriber provisioning change. This will be incremented by the system whenever any change is made. This is used to avoid unnecces… |
| 1.3.6.1.4.1.9.10.26.1.1.7 | ScalarsystemHClockAlarmLevel | read-only | current | This reflects the alarm level of the H-bus backplane clock. H-bus clock error results in critical alarm at the at system level (systemAlarmLevel = critical). |
| 1.3.6.1.4.1.9.10.26.1.1.8 | ScalarsystemFanAlarmLevel | read-only | current | This reflects the alarm level of the fans. Error for this parameter indicates failure of one or more fans. This error results in minor alarm at the system leve… |
| 1.3.6.1.4.1.9.10.26.1.1.9 | ScalarsystemTemperatureAlarmLevel | read-only | current | This reflects the alarm level of the system temperature. When temperature exceeds system preconfigured system allowable limit this parameter indicates an error… |
| 1.3.6.1.4.1.9.10.26.1.1.10 | ScalarsystemACO | read-write | current | This parameter deactivates the audible alarm at the system. Audible alarm is generated by the system to announce detection of new alarm(s). Once deactivated, s… |
| 1.3.6.1.4.1.9.10.26.1.2 | Nodec62Slot | |||
| 1.3.6.1.4.1.9.10.26.1.2.1 | TableslotTable | not-accessible | current | Table contains slot level information such as status, status change time, card type and software version. It is indexed using slot identifier. Empty entries ar… |
| 1.3.6.1.4.1.9.10.26.1.2.1.1 | RowslotEntry | not-accessible | current | Entry in the slot table |
| 1.3.6.1.4.1.9.10.26.1.2.1.1.1 | ColumnslotID | not-accessible | current | Slot Identifier for the selected slot. |
| 1.3.6.1.4.1.9.10.26.1.2.1.1.2 | ColumnslotType | read-only | current | The current type of card in the physical cage, as reported by the system. |
| 1.3.6.1.4.1.9.10.26.1.2.1.1.3 | ColumnslotStatus | read-only | current | The current status of the slot. |
| 1.3.6.1.4.1.9.10.26.1.2.1.1.4 | ColumnslotSwVersion | read-only | current | The currently active firmware version number as a positive whole number, e.g. 100. |
| 1.3.6.1.4.1.9.10.26.1.2.1.1.5 | ColumnslotAlarmLevelChngCounter | read-only | current | Counter indicating change in the port alarm level. This is needed as rising or clearing of an port level alarm may not cause slotAlarmLevel to change. This cou… |
| 1.3.6.1.4.1.9.10.26.1.2.1.1.6 | ColumnslotCnfType | read-write | current | Card type, as provisioned by the operator used to compare against card type reported by the system for monitoring purposes. If slotType and slotCnfType do not … |
| 1.3.6.1.4.1.9.10.26.1.2.1.1.7 | ColumnslotSubscriberChngCounter | read-only | current | Counter indicating change in the subscriber table. This will be incremented by the slot whenever any change is made at the port level. This is used to avoid un… |
| 1.3.6.1.4.1.9.10.26.1.2.1.1.8 | ColumnslotAlarmLevel | read-only | current | This reflects the alarm level of the slot. It is the aggregation of the port level alarms. Alarm levels supported at the slot level are none, minor, major, cri… |
| 1.3.6.1.4.1.9.10.26.1.2.2 | ScalarportID | not-accessible | current | Port Identifier on the targeted slot. PortID value depends on the slot type. |
| 1.3.6.1.4.1.9.10.26.1.3 | Nodec62OCInterface | |||
| 1.3.6.1.4.1.9.10.26.1.3.1 | TableoCInterfaceTable | not-accessible | current | This table contains SONET alarm information. It is indexed using slot and port identifier. Each object represents the alarm level of individual SONET alarm con… |
| 1.3.6.1.4.1.9.10.26.1.3.1.1 | RowoCInterfaceEntry | not-accessible | current | Each entry represents a SONET alarm condition. Following are the definition of SONET level alarms: EQF - Equipment Failure (Local) (causes slotStatus to be cri… |
| 1.3.6.1.4.1.9.10.26.1.3.1.1.2 | ColumnoCIAlarmLevel | read-only | current | The current alarm level on the optical interface, may be none, major, critical or unknown. When the port is experiencing equipment failure or any of the near e… |
| 1.3.6.1.4.1.9.10.26.1.3.1.1.3 | ColumnoCIEQF | read-only | current | Local equipment failure indication. Possible values are none or critical. When this attribute is critical, all other alarm conditions are unknown. |
| 1.3.6.1.4.1.9.10.26.1.3.1.1.4 | ColumnoCILOS | read-only | current | Loss of signal indication. Possible values are none or critical. When this attribute is critical, oCILOF, oCILOP, oCILAIS, oCIPAIS, oCISLM, oCILRFI, oCIPRFI an… |
| 1.3.6.1.4.1.9.10.26.1.3.1.1.5 | ColumnoCILOF | read-only | current | Loss of frame indication. Possible values are none, critical or unknown. When this attribute is critical, oCILAIS, oCILOP, oCIPAIS, oCISLM, oCILRFI, oCIPRFI an… |
| 1.3.6.1.4.1.9.10.26.1.3.1.1.6 | ColumnoCILAIS | read-only | current | Line alarm indication signal. Possible values are none, critical or unknown. When this attribute is critical, oCILOP and oCISLM are unknown. |
| 1.3.6.1.4.1.9.10.26.1.3.1.1.7 | ColumnoCILOP | read-only | current | Loss of pointer indication. Possible values are none, critical or unknown. When this attribute is critical, oCIPAIS, oCISLM and oCILOCD are unknown. |
| 1.3.6.1.4.1.9.10.26.1.3.1.1.8 | ColumnoCIPAIS | read-only | current | Path alarm indication signal. Possible values are none, critical or unknown. When this attribute is critical, oCISLM is unknown. |
| 1.3.6.1.4.1.9.10.26.1.3.1.1.9 | ColumnoCISLM | read-only | current | Signal label mismatch indication. Possible values are none, critical or unknown. |
| 1.3.6.1.4.1.9.10.26.1.3.1.1.10 | ColumnoCILRFI | read-only | current | Line remote failure indication. Possible values are none, critical or unknown. |
| 1.3.6.1.4.1.9.10.26.1.3.1.1.11 | ColumnoCIPRFI | read-only | current | Path remote failure indication. Possible values are none, critical or unknown. |
| 1.3.6.1.4.1.9.10.26.1.3.1.1.12 | ColumnoCILOST | read-only | current | Loss of synchronization indication. Possible values are none, major or unknown. |
| 1.3.6.1.4.1.9.10.26.1.3.1.1.13 | ColumnoCILOCD | read-only | current | Loss of cell delineation. Possible values are none, critical or unknown. |
| 1.3.6.1.4.1.9.10.26.1.3.1.1.14 | ColumnoCILoopMode | read-write | current | This parameter puts the optical interface of C6200 system in facility (far end) loopback mode. It causes the node to loop all the traffic received on the optic… |
| 1.3.6.1.4.1.9.10.26.1.3.2 | TableoCPerfTable | not-accessible | current | This table contains SONET Performance parameters. |
| 1.3.6.1.4.1.9.10.26.1.3.2.1 | RowoCPerfEntry | not-accessible | current | Each entry represents a SONET performance parameters for the targeted port. |
| 1.3.6.1.4.1.9.10.26.1.3.2.1.1 | ColumnoCPTxCellCount | read-only | current | Count of number of non-idle ATM cells inserted into the transmit SONET payload since system start time. This is free running counter and rolls back to zero whe… |
| 1.3.6.1.4.1.9.10.26.1.3.2.1.2 | ColumnoCPRxCellCount | read-only | current | Count of number of ATM cells received at SONET interface since system start time. Idle cells and cells with uncorrectable header errors are not included in the… |
| 1.3.6.1.4.1.9.10.26.1.3.2.1.3 | ColumnoCPHecErrCount | read-only | current | A count of uncorrectable header errors since system start time. This is a free running counter which rolls back to zero when the value exceeds 2^32. |
| 1.3.6.1.4.1.9.10.26.1.4 | Nodec62LineInterface | |||
| 1.3.6.1.4.1.9.10.26.1.4.1 | TablelineInterfaceTable | not-accessible | current | The line table describes basic identification and runtime fault information on the individual subscriber line. A subscriber line consists of a port on the line… |
| 1.3.6.1.4.1.9.10.26.1.4.1.1 | RowlineInterfaceEntry | not-accessible | current | The entry describes the fields being supported by the line table. |
| 1.3.6.1.4.1.9.10.26.1.4.1.1.1 | ColumnlineAlarmLevel | read-only | current | The current alarm level of the port. Refer to TEXTUAL-CONVENTION section for details on AlarmLevel. Only following values for the AlarmLevel are possible for t… |
| 1.3.6.1.4.1.9.10.26.1.4.1.1.2 | ColumnlineDwnSNRMargin | read-only | current | In db, the difference between the current downstream signal to noise ratio and the SNR required for the selected line rate. as seen by the cpe. This object mus… |
| 1.3.6.1.4.1.9.10.26.1.4.1.1.3 | ColumnlineDwnLOCD | read-only | deprecated | Downstream loss of cell delineation. It indicates that the cpe received cells on the line do not contain a valid header error check (HEC). This object is no lo… |
| 1.3.6.1.4.1.9.10.26.1.4.1.1.4 | ColumnlineDwnErrSecs | read-only | current | Downstream count of errored seconds received by the cpe. An error second is a second with line quality problems due to a HEC error in CAP cards or CRC, LOS or … |
| 1.3.6.1.4.1.9.10.26.1.4.1.1.5 | ColumnlineDwnLineRate | read-only | current | Current downstream line rate in kbps. It is adapted by the line card using rate adaptation logic. |
| 1.3.6.1.4.1.9.10.26.1.4.1.1.6 | ColumnlineUpSNRMargin | read-only | current | In db, the difference between the current upstream signal to noise ratio and the SNR required for the selected line rate as seen by the co. This object must be… |
| 1.3.6.1.4.1.9.10.26.1.4.1.1.7 | ColumnlineUpLOCD | read-only | current | Upstream loss of cell delineation. It indicates that the co received cells on the line do not contain a valid header error check (HEC). This alarm will be mark… |
| 1.3.6.1.4.1.9.10.26.1.4.1.1.8 | ColumnlineUpErrSecs | read-only | current | Upstream count of errored seconds recieved by the co. An error second is a second with line quality problems due to a HEC error. or CRC, LOS or SEF events in D… |
| 1.3.6.1.4.1.9.10.26.1.4.1.1.9 | ColumnlineUpLineRate | read-only | current | Current upstream line rate in kbps. This is adapted by the line card using rate adaptation logic. |
| 1.3.6.1.4.1.9.10.26.1.4.1.1.10 | ColumnlineRateAlarm | read-only | current | This parameter is the comparison between actual (lineDwnLineRate/ lineUpLineRate) and the user requested line rates (subscriberDwnLineRate/subscriberUpLineRate… |
| 1.3.6.1.4.1.9.10.26.1.4.1.1.11 | ColumnlineMode | read-only | current | This parameter shows current mode of the line. The possible modes are as shown above. Normally line stays in active mode, if everything is fine. If the line te… |
| 1.3.6.1.4.1.9.10.26.1.4.1.1.12 | ColumnlineDMTDwnAttenuation | read-only | current | Measures downstream attenuation of the line reported by the CPE for the DMT card only. The units for this value are in decibels (dB). This object is instantiat… |
| 1.3.6.1.4.1.9.10.26.1.4.1.1.13 | ColumnlineDMTUpAttenuation | read-only | current | Measures upstream attenuation of the line reported by the CO for the DMT card only. The units for this value are in decibels (dB). This object is instantiated … |
| 1.3.6.1.4.1.9.10.26.1.4.1.1.14 | ColumnlineDMTDwnLPR | read-only | current | Downstream loss of power indicator reported by the CPE for the DMT card only. Valid values are minor, unknown, or none. When this alarm is minor, lineUpLOS, li… |
| 1.3.6.1.4.1.9.10.26.1.4.1.1.15 | ColumnlineDMTUpLOS | read-only | current | Upstream loss of signal alarm indicator reported by the CO for the DMT card only. Valid values are minor or none. When this alarm is minor, lineDMTUpLOF and li… |
| 1.3.6.1.4.1.9.10.26.1.4.1.1.16 | ColumnlineDMTUpLOF | read-only | current | Upstream loss of frame alarm indicator reported by the CO for the DMT card only. Valid values are minor or none. When this alarm is minor, lineUpLOCD is unknow… |
| 1.3.6.1.4.1.9.10.26.1.4.1.1.17 | ColumnlineDMTLoopback | read-write | current | DMT supported ATM layer loopback. dslline loops all ATM cells toward the CO modem back to the CPE. Local loops all ATM cells sent by the ATM trunk card toward … |
| 1.3.6.1.4.1.9.10.26.1.4.2 | TablelinePerfTable | not-accessible | current | This table contains line performance parameters. It contains one entry per subscriber line. Only the ATU-C (local) performance parameters are reported in this … |
| 1.3.6.1.4.1.9.10.26.1.4.2.1 | RowlinePerfEntry | not-accessible | current | Each entry represents a performance parameter for the targeted subscriber line. |
| 1.3.6.1.4.1.9.10.26.1.4.2.1.1 | ColumnlineTxCellCount | read-only | current | Total cell count in the downstream direction (ATU-C->ATU-R) reported by the CPE. The counter value does not include cells with uncorrectable HEC errors. This i… |
| 1.3.6.1.4.1.9.10.26.1.4.2.1.2 | ColumnlineRxCellCount | read-only | current | Total cell count in the upstream direction (ATU-R->ATU-C) reported by the CO. The counter value does not include cells with uncorrectable HEC errors. This is a… |
| 1.3.6.1.4.1.9.10.26.1.4.2.1.3 | ColumnlineHecErrCount | read-only | current | Total HEC error count in the upstream (ATU-R->ATU-C) direction reported by the CO. This is a free running counter which rolls back to zero when the value excee… |
| 1.3.6.1.4.1.9.10.26.1.4.2.1.4 | ColumnlineDMTDwnFECCount | read-only | current | Downstream count of forward error correction (FEC) events reported by the CPE for the DMT card only. |
| 1.3.6.1.4.1.9.10.26.1.4.2.1.5 | ColumnlineDMTUpFECCount | read-only | current | Upstream count of forward error correction (FEC) events reported by the CO for the DMT card only. This object is instantiated for the CAP card. |
| 1.3.6.1.4.1.9.10.26.1.4.2.1.6 | ColumnlineDMTDwnCRCCount | read-only | current | Downstream count of cyclical error correction (CRC) events reported by the CPE for the DMT card only. This object is instantiated for the CAP card. |
| 1.3.6.1.4.1.9.10.26.1.4.2.1.7 | ColumnlineDMTUpCRCCount | read-only | current | Upstream count of cyclical error correction (CRC) events reported by the CO for the DMT card only. This object is instantiated for the CAP card. |
| 1.3.6.1.4.1.9.10.26.1.4.2.1.8 | ColumnlineDMTDwnLOSCount | read-only | current | Downstream count of loss of signal (LOS) events reported by the CPE for the DMT card only. This object is instantiated for the CAP card. |
| 1.3.6.1.4.1.9.10.26.1.4.2.1.9 | ColumnlineDMTUpLOSCount | read-only | current | Upstream count of loss of signal (LOS) events reported by the CO for the DMT card only. This object is instantiated for the CAP card. |
| 1.3.6.1.4.1.9.10.26.1.4.2.1.10 | ColumnlineDMTDwnSEFCount | read-only | current | Downstream count of severly errored frame (SEF) events reported by the CPE for the DMT card only. This object is instantiated for the CAP card. |
| 1.3.6.1.4.1.9.10.26.1.4.2.1.11 | ColumnlineDMTUpRDICount | read-only | current | Upstream count of remote defect indication (RDI) events reported by the CO for the DMT card only. This object is instantiated for the CAP card. |
| 1.3.6.1.4.1.9.10.26.1.4.3 | TablelineTestTable | not-accessible | current | The Line test table contains the line test parameters per subscriber line. It controls access to the testing capabilities at the subscriber line level. This ta… |
| 1.3.6.1.4.1.9.10.26.1.4.3.1 | RowlineTestEntry | not-accessible | current | The entry describes the fields supported by the line test table. |
| 1.3.6.1.4.1.9.10.26.1.4.3.1.1 | ColumnlineTestTrigger | read-write | current | Starts or stops (aborts) a test in progress. The agent will only start a new test, if no test is active on the targeted port. The user must set lineTestTimeInt… |
| 1.3.6.1.4.1.9.10.26.1.4.3.1.2 | ColumnlineTestType | read-write | current | The type of the test to be performed. If capHardware test is selected, time interval is determined by the system. Both the test types are destructive: affects … |
| 1.3.6.1.4.1.9.10.26.1.4.3.1.3 | ColumnlineTestTimeIntvl | read-write | current | Time interval in minutes between 0 - 60 minutes. This parameter is only meaningful, if test type is the line quality test. Default value is 30 minutes. The age… |
| 1.3.6.1.4.1.9.10.26.1.4.3.1.4 | ColumnlineTestStatus | read-only | current | System changes values for this variable based on trigger value as well as based on system reported result. When test completes, system compares lineTestDwnBitE… |
| 1.3.6.1.4.1.9.10.26.1.4.3.1.5 | ColumnlineTestDwnBitErrRate | read-only | current | This is positive integer value representing a negative exponent of 10 for the error rate in the downstream direction. It is only meaningful when the line quali… |
| 1.3.6.1.4.1.9.10.26.1.4.3.1.6 | ColumnlineTestUpBitErrRate | read-only | current | This is positive integer value representing a negative exponent of 10 for the error rate in the upstream direction. It is only meaningful when the line quality… |
| 1.3.6.1.4.1.9.10.26.1.4.3.1.7 | ColumnlineTestStartTime | read-only | current | Time stamp in displayable format. This is the time when the system starts the requested test. |
| 1.3.6.1.4.1.9.10.26.1.4.3.1.8 | ColumnlineTestCmplTime | read-only | current | Time stamp in displayable format. This is the time when the system completes the requested test or when the user aborts the test. |
| 1.3.6.1.4.1.9.10.26.1.4.3.1.9 | ColumnlineTestBitErrRateLimit | read-write | current | This is a positive integer representing a negative exponent of 10. It represents bit error rate limit allowed for the subscriber line quality test. The system … |
| 1.3.6.1.4.1.9.10.26.1.5 | Nodec62Subscriber | |||
| 1.3.6.1.4.1.9.10.26.1.5.1 | TablesubscriberTable | not-accessible | current | The subscriber table contains configuration information per subscriber line. Non-assigned entries are identified by NULL string for the subscriber name. It con… |
| 1.3.6.1.4.1.9.10.26.1.5.1.1 | RowsubscriberEntry | not-accessible | current | The entry describes the fields being supported by the subscriber table. |
| 1.3.6.1.4.1.9.10.26.1.5.1.1.1 | ColumnsubscriberName | read-write | current | The subscriber Id, free format string field. First character can not be a space. Set this field to NULL string to delete a subscriber entry from the database. … |
| 1.3.6.1.4.1.9.10.26.1.5.1.1.2 | ColumnsubscriberUpLineRate | read-write | current | Desired maximum line rate. Actual rate may be lower following training sequence to acquire that rate. Refer to system features document for valid range. When t… |
| 1.3.6.1.4.1.9.10.26.1.5.1.1.3 | ColumnsubscriberDwnLineRate | read-write | current | Desired maximum line rate. Actual rate may be lower following training sequence to acquire that rate. Refer to system features document for valid range. When t… |
| 1.3.6.1.4.1.9.10.26.1.5.1.1.4 | ColumnsubscriberLineState | read-write | current | This parameter reflects current state of the subscriber line. It allows targeted subscriber line to be enabled or disabled. Disabling the line cuts off service… |
| 1.3.6.1.4.1.9.10.26.1.5.1.1.5 | ColumnsubscriberDMTLOSConfig | read-write | current | This value determines whether or not the LOS condition on the subscriber line generates a minor alarm. By default, this value is set to disabled which means th… |
| 1.3.6.1.4.1.9.10.26.2 | NodeciscoC6200MIBConformance | |||
| 1.3.6.1.4.1.9.10.26.2.1 | NodeciscoC6200MIBCompliances | |||
| 1.3.6.1.4.1.9.10.26.2.1.1 | ComplianceciscoC6200MIBCompliance | obsolete | The compliance statement for entities which implement the Cisco C6200 MIB. This device-specific MIB will be implemented only by members of the C6200 product li… | |
| 1.3.6.1.4.1.9.10.26.2.1.2 | ComplianceciscoC6200MIBCompliance2 | current | The compliance statement for entities which implement the Cisco C6200 MIB. This device-specific MIB will be implemented only by members of the C6200 product li… | |
| 1.3.6.1.4.1.9.10.26.2.2 | NodeciscoC6200MIBGroups | |||
| 1.3.6.1.4.1.9.10.26.2.2.1 | GroupciscoC6200SystemGroup | obsolete | System-level information for a C6200 device. | |
| 1.3.6.1.4.1.9.10.26.2.2.2 | GroupciscoC6200SlotGroup | obsolete | Slot-level information for a C6200 device. | |
| 1.3.6.1.4.1.9.10.26.2.2.3 | GroupciscoC6200oCIGroup | obsolete | NTC information for a C6200 device. | |
| 1.3.6.1.4.1.9.10.26.2.2.4 | GroupciscoC6200oCIPerfGroup | obsolete | NTC performance information for a C6200 device. | |
| 1.3.6.1.4.1.9.10.26.2.2.5 | GroupciscoC6200lineGroup | obsolete | Line-level information for a C6200 device. | |
| 1.3.6.1.4.1.9.10.26.2.2.6 | GroupciscoC6200linePerfGroup | obsolete | Line-level performance information for a C6200 device. | |
| 1.3.6.1.4.1.9.10.26.2.2.7 | GroupciscoC6200lineTestGroup | obsolete | Line-level test information for a C6200 device. | |
| 1.3.6.1.4.1.9.10.26.2.2.8 | GroupciscoC6200subscriberGroup | obsolete | Subscriber-level information for a C6200 device. | |
| 1.3.6.1.4.1.9.10.26.2.2.9 | GroupciscoC6200SystemGroup2 | current | System-level information for a C6200 device. | |
| 1.3.6.1.4.1.9.10.26.2.2.10 | GroupciscoC6200SlotGroup2 | current | Slot-level information for a C6200 device. | |
| 1.3.6.1.4.1.9.10.26.2.2.11 | GroupciscoC6200oCIGroup2 | current | NTC information for a C6200 device. | |
| 1.3.6.1.4.1.9.10.26.2.2.12 | GroupciscoC6200oCIPerfGroup2 | current | NTC performance information for a C6200 device. | |
| 1.3.6.1.4.1.9.10.26.2.2.13 | GroupciscoC6200lineGroup2 | current | Line-level information for a C6200 device. | |
| 1.3.6.1.4.1.9.10.26.2.2.14 | GroupciscoC6200linePerfGroup2 | current | Line-level performance information for a C6200 device. | |
| 1.3.6.1.4.1.9.10.26.2.2.15 | GroupciscoC6200lineTestGroup2 | current | Line-level test information for a C6200 device. | |
| 1.3.6.1.4.1.9.10.26.2.2.16 | GroupciscoC6200subscriberGroup2 | current | Subscriber-level information for a C6200 device. |
Type Definitions
| Name | Syntax | Status | Description |
|---|---|---|---|
| AlarmLevel | INTEGER { none (1), minor (2), major (3), critical (4), unknown (5) } | current | Represents error status. |
| C6200CardType | INTEGER { oc3si (1), ctl (2), cap8 (3), cap16 (4), oc3ss (5), oc3mm (6), stm1si (7), stm1mm (8), dmt8 (9), none (-1) } | current | Represents card types contained in the C6200 product lines. oc3si - one port, single mode, intermediate reach OC3 - based interface card ctl - controller card cap8 - eight port CAP RADSL interface card cap16 - sixteen p… |
| CommandValue | INTEGER { ready (1), execute (2) } | current | This parameter controls execution of a command. The intended command can be triggered by setting its value to execute. Its value goes back to ready when intended command execution is complete. |
| InterfaceStatus | INTEGER { enabled (1), disabled (2) } | current | Represents interface status. |
| TestStatus | INTEGER { inactive (1), active (2), pass (3), fail (4), aborted (5), waiting (6) } | current | Represents status of the test per subscriber line. Please refer to lineTestTable for details on how to start a test. Once test completes or aborted, status stays as pass, fail, or aborted respectively until user clears … |
| TestType | INTEGER { none (0), lineQuality (1), capHardware (2), dmtLocalTest (3) } | current | Represents Types of tests support per line. |