MIB Viewer

CISCO-BSC-MIB

47 objects
The MIB module for BSC. Overview of BSC MIB MIB description The BSC MIB provides the configuration and operational information on Cisco's Binary Synchronous Communications implementation. The following entities are managed: 1) BSC ports (serial interfaces) 2) BSC Control Units (stations on a port) The BSC ports are identified by the interface index, and additional information about this interface can be obtained from the Cisco Serial Interface MIB. The BSC Control Units are identified by the Control Unit address; this is the address used by BSTUN to route the BSC traffic - it is therefore equivalent to the bstunRouteStationAddress in the bstunRouteTable MIB.
Imported Objects
CISCO-SMIciscoMgmt
IF-MIBifIndex
SNMPv2-CONFMODULE-COMPLIANCE OBJECT-GROUP
SNMPv2-SMICounter32 Integer32 MODULE-IDENTITY OBJECT-TYPE
SNMPv2-TCTruthValue
OIDNameAccessStatusDescription
1.3.6.1.4.1.9.9.36IdentityciscoBscMIBThe MIB module for BSC. Overview of BSC MIB MIB description The BSC MIB provides the configuration and operational information on Cisco's Binary Synchronous Co…
1.3.6.1.4.1.9.9.36.1NodebscObjects
1.3.6.1.4.1.9.9.36.1.1NodebscPorts
1.3.6.1.4.1.9.9.36.1.1.1TablebscPortTablenot-accessiblecurrentA list of port (serial interfaces) which have been configured to support a BSC BSTUN group.
1.3.6.1.4.1.9.9.36.1.1.1.1RowbscPortEntrynot-accessiblecurrentStatus and parameter values for a port.
1.3.6.1.4.1.9.9.36.1.1.1.1.1ColumnbscPortRoleread-onlycurrentThe router's DLC role to the attached node. If the bscPortRole is primary, this implies that the port is connected to a remote secondary device. If the role is…
1.3.6.1.4.1.9.9.36.1.1.1.1.2ColumnbscPortCodeSetread-onlycurrentThe code set used for the line controls.
1.3.6.1.4.1.9.9.36.1.1.1.1.3ColumnbscPortPauseread-onlycurrentFor primary, it is the minimum time to be taken for a cycle round the active poll table; if this time has not elapsed when the bottom of the poll table is reac…
1.3.6.1.4.1.9.9.36.1.1.1.1.4ColumnbscPortServlimread-onlycurrentThis parameter is valid for primary only. It is the number of times the active poll table will be cycled before a non-responding control unit will be polled. T…
1.3.6.1.4.1.9.9.36.1.1.1.1.5ColumnbscPortPollTimeoutread-onlycurrentThis parameter is valid for primary only. It is the time that the primary will wait for a response to a poll or select. The units are tenths of a second. The d…
1.3.6.1.4.1.9.9.36.1.1.1.1.6ColumnbscPortRecoveryRetriesread-onlycurrentThis is the number of times that a recovery sequence will be retried before the connection is considered to have failed. The default is 5.
1.3.6.1.4.1.9.9.36.1.1.1.1.7ColumnbscPortUnknownControlUnitsReceivedread-onlycurrentCount of frames received from the serial interface with an unsupported control unit address. If this value is non-zero it indicates a problem in the configurat…
1.3.6.1.4.1.9.9.36.1.1.1.1.8ColumnbscPortSoftErrorsread-onlycurrentCount of soft errors; these are errors which have been recovered. This includes CRC errors received, frames which were retransmitted for any reason (NAK receiv…
1.3.6.1.4.1.9.9.36.1.1.1.1.9ColumnbscPortHardErrorsread-onlycurrentCount of hard errors; these are errors which have not been recovered after bscPortRecoveryRetries number of retries, and therefore the connection has been term…
1.3.6.1.4.1.9.9.36.1.1.1.1.10ColumnbscPortProtocolViolationsread-onlycurrentCount of protocol violations. This counter is incremented when an unexpected BSC Data Link Control character is received from the remote device; that is, the c…
1.3.6.1.4.1.9.9.36.1.1.1.1.11ColumnbscPortHostTimeoutread-onlycurrentThis parameter is valid for interfaces configured secondary which additionally are running local-acknowledgement. If the configuration does not match the value…
1.3.6.1.4.1.9.9.36.1.1.1.1.12ColumnbscPortSpecPollread-onlycurrentThis parameter is valid for primary, local-acknowledgement interfaces only. It is set to TRUE when the interface is configured to treat specific polls as gener…
1.3.6.1.4.1.9.9.36.1.1.1.1.13ColumnbscPortVirtualAddressread-onlycurrentThis parameter is valid for contention only. It is the address to be used for this interface when the remote peer router is being used as a concentrator. The d…
1.3.6.1.4.1.9.9.36.1.1.1.1.14ColumnbscPortContentionDialTimeoutread-onlycurrentThis parameter is valid for dialContention only. It is the amount of time an interface can be quiescent before return the interface to the dial-in pool. The de…
1.3.6.1.4.1.9.9.36.1.2NodebscControlUnits
1.3.6.1.4.1.9.9.36.1.2.1TablebscControlUnitTablenot-accessiblecurrentA table containing information about specific Control Units.
1.3.6.1.4.1.9.9.36.1.2.1.1RowbscCUEntrynot-accessiblecurrentThe information regarding a single Control Unit.
1.3.6.1.4.1.9.9.36.1.2.1.1.1ColumnbscCUAddressnot-accessiblecurrentThis value is the poll address of the BSC Control Unit. This address must be unique within a BSTUN Group.
1.3.6.1.4.1.9.9.36.1.2.1.1.2ColumnbscCUStateread-onlycurrentState of the BSC Control Unit; when active this indicates that the remote Control Unit is polling or responding to polls.
1.3.6.1.4.1.9.9.36.1.2.1.1.3ColumnbscCUBytesSentread-onlycurrentCount of sent bytes (octets). Includes all control characters.
1.3.6.1.4.1.9.9.36.1.2.1.1.4ColumnbscCUBytesReceivedread-onlycurrentCount of received bytes (octets). Includes all control characters.
1.3.6.1.4.1.9.9.36.1.2.1.1.5ColumnbscCUTotalFramesSentread-onlycurrentCount of sent frames (blocks). Includes all control frames.
1.3.6.1.4.1.9.9.36.1.2.1.1.6ColumnbscCUTotalFramesReceivedread-onlycurrentCount of received frames (blocks). Includes all control frames.
1.3.6.1.4.1.9.9.36.1.2.1.1.7ColumnbscCUDataFramesSentread-onlycurrentCount of sent data frames (blocks).
1.3.6.1.4.1.9.9.36.1.2.1.1.8ColumnbscCUDataFramesReceivedread-onlycurrentCount of received data frames (blocks).
1.3.6.1.4.1.9.9.36.1.2.1.1.9ColumnbscCUSoftErrorsread-onlycurrentCount of soft errors; these are errors which have been recovered. This includes CRC errors received, frames which were retransmitted for any reason (NAK receiv…
1.3.6.1.4.1.9.9.36.1.2.1.1.10ColumnbscCUHardErrorsread-onlycurrentCount of hard errors; these are errors which have not been recovered after bscPortRecoveryRetries number of retries, and therefore the connection has been term…
1.3.6.1.4.1.9.9.36.1.2.1.1.11ColumnbscCUProtocolViolationsread-onlycurrentCount of protocol violations. This counter is incremented when an unexpected BSC Data Link Control character is received from the remote device; that is, the c…
1.3.6.1.4.1.9.9.36.1.3NodebscExtAddresses
1.3.6.1.4.1.9.9.36.1.3.1TablebscExtAddressTablenot-accessiblecurrentList of all addresses configured by the bsc extended-address command. This applies only to interfaces with an ifType of 'bsc'. The address entries must be uniq…
1.3.6.1.4.1.9.9.36.1.3.1.1RowbscExtAddressEntrynot-accessiblecurrentThe information regarding a single extended addresses.
1.3.6.1.4.1.9.9.36.1.3.1.1.1ColumnbscExtPollAddressnot-accessiblecurrentThe poll address of the station configured by the bsc extended-address command.
1.3.6.1.4.1.9.9.36.1.3.1.1.2ColumnbscExtSelectAddressread-onlycurrentThe select address of the station configured by the bsc extended-address command.
1.3.6.1.4.1.9.9.36.3NodebscMibConformance
1.3.6.1.4.1.9.9.36.3.1NodebscMibCompliances
1.3.6.1.4.1.9.9.36.3.1.1CompliancebscMibComplianceobsoleteThe compliance statement for BSTUN.
1.3.6.1.4.1.9.9.36.3.1.2CompliancebscMibComplianceRev1currentThe compliance statement for all Cisco Systems that implement BSC functions.
1.3.6.1.4.1.9.9.36.3.2NodebscMibGroups
1.3.6.1.4.1.9.9.36.3.2.1GroupbscPortsGroupobsoleteA collection of objects providing information about BSC enabled interfaces.
1.3.6.1.4.1.9.9.36.3.2.2GroupbscControlUnitsGroupcurrentA collection of objects providing information about BSC Control Units .
1.3.6.1.4.1.9.9.36.3.2.3GroupbscPortsGroupRev1currentA collection of objects providing information about BSC enabled interfaces.
1.3.6.1.4.1.9.9.36.3.2.4GroupbscExtAddressGroupcurrentA collection of objects providing information about BSC extended addresses.