CISCO-CABLE-DIAG-MIB
34 objects
This MIB module defines objects for managing cable diagnostic test capabilites supported by the Cisco devices. Cable diagnostic tests are tests intended to exercise the functional integrity of the cable attached to a physical interface. Examples of cable diagnostic test methods are: PRBS (Pesudo Random Binary Sequence), TDR (Time Domain reflectometery), etc..
Imported Objects
| CISCO-SMI | ciscoMgmt |
| IF-MIB | ifIndex |
| SNMPv2-CONF | MODULE-COMPLIANCE OBJECT-GROUP |
| SNMPv2-SMI | Gauge32 Integer32 MODULE-IDENTITY OBJECT-TYPE Unsigned32 |
| SNMPv2-TC | TimeStamp TruthValue |
| OID | Name | Access | Status | Description |
|---|---|---|---|---|
| 1.3.6.1.4.1.9.9.390 | IdentityciscoCableDiagMIB | This MIB module defines objects for managing cable diagnostic test capabilites supported by the Cisco devices. Cable diagnostic tests are tests intended to exe… | ||
| 1.3.6.1.4.1.9.9.390.0 | NodeciscoCableDiagMIBNotifs | |||
| 1.3.6.1.4.1.9.9.390.1 | NodeciscoCableDiagMIBObjects | |||
| 1.3.6.1.4.1.9.9.390.1.1 | NodeccdPrbsObjects | |||
| 1.3.6.1.4.1.9.9.390.1.1.1 | TableccdPrbsIfTable | not-accessible | current | A table containing information about PRBS (Pesudo Random Binary Sequence) test on the device's interfaces. An entry appears in this table for each interface wh… |
| 1.3.6.1.4.1.9.9.390.1.1.1.1 | RowccdPrbsIfEntry | not-accessible | current | An entry in the ccdPrbsIfTable, containing the information about PRBS test on an interface. |
| 1.3.6.1.4.1.9.9.390.1.1.1.1.1 | ColumnccdPrbsIfAction | read-write | current | Indicates the PRBS test action to be executed on the interface and whether the test is currently running or not. 'start' 'stop' 'errorReset' ccdPrbsIfTestError… |
| 1.3.6.1.4.1.9.9.390.1.1.1.1.2 | ColumnccdPrbsIfActionStatus | read-only | current | Indicates the status of the last PRBS test action set on the interface. |
| 1.3.6.1.4.1.9.9.390.1.1.1.1.3 | ColumnccdPrbsIfTestErrors | read-only | current | Indicates the number of errors which occurred during the current or most recent running of a test. This Gauge is reset to zero each time a test starts (e.g., w… |
| 1.3.6.1.4.1.9.9.390.1.1.1.1.4 | ColumnccdPrbsIfTestErrorsResetTime | read-only | current | Indicates the most recent time that the corresponding instance of ccdPrbsIfTestErrors is reset to zero. If the the corresponding instance of ccdPrbsIfTestError… |
| 1.3.6.1.4.1.9.9.390.1.1.1.1.5 | ColumnccdPrbsIfTestErrorsMaxValue | read-only | current | Indicates the maximum value of the corresponding instance of ccdPrbsIfTestErrors. |
| 1.3.6.1.4.1.9.9.390.1.2 | NodeccdTdrObjects | |||
| 1.3.6.1.4.1.9.9.390.1.2.1 | TableccdTdrIfTable | not-accessible | current | A table containing information about TDR (Time Domain Reflectometery) test on the device's interfaces. An entry appears in this table for each interface which … |
| 1.3.6.1.4.1.9.9.390.1.2.1.1 | RowccdTdrIfEntry | not-accessible | current | An entry in the ccdTdrIfTable, containing the information about TDR test on an interface. |
| 1.3.6.1.4.1.9.9.390.1.2.1.1.1 | ColumnccdTdrIfAction | read-write | current | Indicates the TDR test action to be executed on the interface and whether the test is currently running or not. 'start' 'clear' After this action is executed o… |
| 1.3.6.1.4.1.9.9.390.1.2.1.1.2 | ColumnccdTdrIfActionStatus | read-only | current | Indicates the status of the last TDR test action set on the interface. |
| 1.3.6.1.4.1.9.9.390.1.2.1.1.3 | ColumnccdTdrIfLastTestTime | read-only | current | Indicates the timestamp when TDR test is last run on the interface. If TDR test is never run on an interface, then this object value will be zero. |
| 1.3.6.1.4.1.9.9.390.1.2.1.1.4 | ColumnccdTdrIfResultValid | read-only | current | Indicates whether the TDR test result on the interface is valid for the user to retrieve or not. |
| 1.3.6.1.4.1.9.9.390.1.2.2 | TableccdTdrIfResultTable | not-accessible | current | A table containing information about TDR test result on the device's interfaces. An entry appears in this table for each cable pair on an interface which has v… |
| 1.3.6.1.4.1.9.9.390.1.2.2.1 | RowccdTdrIfResultEntry | not-accessible | current | An entry in the ccdTdrIfResultTable, containing the information about TDR test on an interface. |
| 1.3.6.1.4.1.9.9.390.1.2.2.1.1 | ColumnccdTdrIfResultPairIndex | not-accessible | current | The local cable pair index. 'pair1to2' 'pair3to6' 'pair4to5' 'pair7to8' REFERENCE |
| 1.3.6.1.4.1.9.9.390.1.2.2.1.2 | ColumnccdTdrIfResultPairChannel | read-only | current | |
| 1.3.6.1.4.1.9.9.390.1.2.2.1.3 | ColumnccdTdrIfResultPairLength | read-only | current | The length of the cable pair. A value of -1 indicates the length value is invalid. The unit of this value is indicated by ccdTdrIfResultPairLengthUnit of the s… |
| 1.3.6.1.4.1.9.9.390.1.2.2.1.4 | ColumnccdTdrIfResultPairLenAccuracy | read-only | current | The length accuracy of the cable pair. This value should be added to and deducted from the value of ccdTdrIfResultPairLength of the same cable pair to form the… |
| 1.3.6.1.4.1.9.9.390.1.2.2.1.5 | ColumnccdTdrIfResultPairDistToFault | read-only | current | The distance to the fault point of the cable pair. A value of -1 indicates this value is invalid. The unit of this value is indicated by ccdTdrIfResultPairLeng… |
| 1.3.6.1.4.1.9.9.390.1.2.2.1.6 | ColumnccdTdrIfResultPairDistAccuracy | read-only | current | The accuracy of the distance to the fault point for the cable pair. This value should be added to and deducted from the value of ccdTdrIfResultPairDistToFault … |
| 1.3.6.1.4.1.9.9.390.1.2.2.1.7 | ColumnccdTdrIfResultPairLengthUnit | read-only | current | |
| 1.3.6.1.4.1.9.9.390.1.2.2.1.8 | ColumnccdTdrIfResultPairStatus | read-only | current | |
| 1.3.6.1.4.1.9.9.390.2 | NodeciscoCableDiagMIBConform | |||
| 1.3.6.1.4.1.9.9.390.2.1 | NodeciscoCableDiagMIBCompliances | |||
| 1.3.6.1.4.1.9.9.390.2.1.1 | ComplianceciscoCableDiagMIBComplianceRev1 | current | The compliance statement for SNMP entities that implement the CISCO-CABLE-DIAG-MIB. | |
| 1.3.6.1.4.1.9.9.390.2.2 | NodeciscoCableDiagMIBGroups | |||
| 1.3.6.1.4.1.9.9.390.2.2.1 | GroupccdPrbsGroup | current | A collection of managed objects to support PRBS cable diagnotic test on the interfaces of the device. | |
| 1.3.6.1.4.1.9.9.390.2.2.2 | GroupccdTdrGroup | current | A collection of managed objects to support TDR cable diagnotic test on the interfaces of the device. |