CISCO-ENTITY-PFE-MIB

65 objects
The Packet Forwarding Engine technology are Cisco developed Network Processors, which accelerates certain features in order to provide better network performance. An agent uses this MIB to monitor the performance history on any active PFE pipeline listed in the ENTITY-MIB (RFC 2737) entPhysicalTable. This monitoring is via measurement periods of actual, 1-minute, 5-minutes and 15-minutes. For the 1-minute and 5-minute measurement periods, perfor- mance statistics are calculated and displayed based on pre- vious 1 minute and 5 minute respectively. For the 15-minute period, the performance statistics are accumulated in fifteen minute intervals. At any one time, an agent maintains one current (incomplete) interval and up to 96 completed intervals (24 hours worth). Fewer than 96 intervals of data will be available if the agent has been restarted within the last 24 hours. In addition, there is a rolling 24-hour total of each performance statistic. There is no requirement for an agent to ensure fixed rela- tionship between the start of a fifteen minute interval and any wall clock; however some agents may align the fifteen minute intervals with quarter hours.
Imported Objects
CISCO-SMIciscoMgmt
ENTITY-MIBentPhysicalIndex PhysicalIndex
SNMPv2-CONFMODULE-COMPLIANCE NOTIFICATION-GROUP OBJECT-GROUP
SNMPv2-SMIGauge32 MODULE-IDENTITY NOTIFICATION-TYPE OBJECT-TYPE Unsigned32
SNMPv2-TCDisplayString TEXTUAL-CONVENTION TimeStamp
OIDNameAccessStatusDescription
1.3.6.1.4.1.9.9.265IdentityciscoEntityPfeMibThe Packet Forwarding Engine technology are Cisco developed Network Processors, which accelerates certain features in order to provide better network performan…
1.3.6.1.4.1.9.9.265.0NodecePfeMIBNotifications
1.3.6.1.4.1.9.9.265.0.1NotificationcePfeHistThldEventcurrentThis notification is generated when a threshold event has occurred and the cePfeHistNotifiesEnable is set to 'notify (3)' or 'logAndNotify(4)'. After generatin…
1.3.6.1.4.1.9.9.265.0.2NotificationcePfeHistRestartEventcurrentThis notification is generated when a restart event has occurred and the cePfeHistNotifiesEnable is set to 'notifyp (3)' or 'logAndNotify(4)'.
1.3.6.1.4.1.9.9.265.1NodecePfeMIBObjects
1.3.6.1.4.1.9.9.265.1.1NodecePfePerformance
1.3.6.1.4.1.9.9.265.1.1.1TablecePfePerfConfigTablenot-accessiblecurrentThis table contains configuration information on a PFE pipeline.
1.3.6.1.4.1.9.9.265.1.1.1.1RowcePfePerfConfigEntrynot-accessiblecurrentAn entry will exist for each entry in the entPhysicalTable that correspond to an active PFE pipeline.
1.3.6.1.4.1.9.9.265.1.1.1.1.1ColumncePfePerfConfigTimeElapsedread-onlycurrentThe number of seconds that have elapsed since the beginning of the current 15 min interval. If for some reason, such as an adjustment in the system's time-of-d…
1.3.6.1.4.1.9.9.265.1.1.1.1.2ColumncePfePerfConfigValidIntervalsread-onlycurrentThe number of completed 15 min intervals for which valid PFE performance data has been collected. The value will be 96 unless the interface was brought online …
1.3.6.1.4.1.9.9.265.1.1.1.1.3ColumncePfePerfConfigThldUtilizationread-writecurrentThis object contains the threshold value for the cePfePerfCurrentUtilization object. If during the last 5 second measurement period the cePfePerfCurrentUtiliza…
1.3.6.1.4.1.9.9.265.1.1.1.1.4ColumncePfePerfConfigThldEfficiencyread-writecurrentThis object contains the threshold value for the cePfePerfCurrentEffciency object. If during the last 5 second measurement period the cePfePerfCurrentEfficienc…
1.3.6.1.4.1.9.9.265.1.1.1.1.5ColumncePfePerfConfigThld1MinUtilizationread-writecurrentThis object contains the threshold value for the cePfePerfCurrent1MinUtilization object. If during the last 1 minute measurement period the cePfePerfCurrent1Mi…
1.3.6.1.4.1.9.9.265.1.1.1.1.6ColumncePfePerfConfigThld1MinEfficiencyread-writecurrentThis object contains the threshold value for the cePfePerfCurrent1MinEfficiency object. If during the last 1 minute measurement period the cePfePerfCurrent1Min…
1.3.6.1.4.1.9.9.265.1.1.1.1.7ColumncePfePerfConfigThld5MinUtilizationread-writecurrentThis object contains the threshold value for the cePfePerfCurrent5MinUtilization object. If during the last 5 minute measurement period the cePfePerfCurrent5Mi…
1.3.6.1.4.1.9.9.265.1.1.1.1.8ColumncePfePerfConfigThld5MinEfficiencyread-writecurrentThis object contains the threshold value for the cePfePerfCurrent5MinEfficiency object. If during the last 5 minute measurement period the cePfePerfCurrent5Min…
1.3.6.1.4.1.9.9.265.1.1.2TablecePfePerfCurrentTablenot-accessiblecurrentThis table maintains PFE current running performance, which are collected at various measurement periods.
1.3.6.1.4.1.9.9.265.1.1.2.1RowcePfePerfCurrentEntrynot-accessiblecurrentAn entry containing performance information applicable to a particular PFE pipeline.
1.3.6.1.4.1.9.9.265.1.1.2.1.1ColumncePfePerfCurrentUtilizationread-onlycurrentThis object provides the actual PFE percentage utilization. It is determined by the number of new work contexts + feedback contexts divided by total number of …
1.3.6.1.4.1.9.9.265.1.1.2.1.2ColumncePfePerfCurrentEfficiencyread-onlycurrentThis object provides the actual PFE percentage efficiency. It is determined by the total number of contexts per second divided by maximum theoretical contexts …
1.3.6.1.4.1.9.9.265.1.1.2.1.3ColumncePfePerfCurrent1MinUtilizationread-onlycurrentThis object provides the PFE percentage utilization over the previous 1 minute period. It is determined by the number of new work contexts + feedback contexts …
1.3.6.1.4.1.9.9.265.1.1.2.1.4ColumncePfePerfCurrent1MinEfficiencyread-onlycurrentThis object provides the PFE percentage efficiency over the previous 1 minute period. It is determined by the totalnumber of contexts per second divided by max…
1.3.6.1.4.1.9.9.265.1.1.2.1.5ColumncePfePerfCurrent5MinUtilizationread-onlycurrentThis object provides the PFE percentage utilization over the previous 5 minutes period. It is determined by the number of new work contexts + feedback contexts…
1.3.6.1.4.1.9.9.265.1.1.2.1.6ColumncePfePerfCurrent5MinEfficiencyread-onlycurrentThis object provides the PFE percentage efficiency over the previous 5 minutes period. It is determined by the total number of contexts per second divided by m…
1.3.6.1.4.1.9.9.265.1.1.3TablecePfePerfIntervalTablenot-accessiblecurrentThis table contains performance statistics for completed 15 minutes intervals, specifically up to 96 such intervals over a 24 hours of operation.
1.3.6.1.4.1.9.9.265.1.1.3.1RowcePfePerfIntervalEntrynot-accessiblecurrentAn entry containing performance information applicable to a particular PFE pipeline at a specific interval.
1.3.6.1.4.1.9.9.265.1.1.3.1.1ColumncePfePerfIntervalNumbernot-accessiblecurrentAn interval number between 1 and 96, where 1 is the most recently completed 15 min interval and 96 is the 15 min interval completed 23 hours and 45 minutes pri…
1.3.6.1.4.1.9.9.265.1.1.3.1.2ColumncePfePerfIntervalUtilizationread-onlycurrentThe percentage of processor utilization by the PFE pipeline during this completed 15 min interval.
1.3.6.1.4.1.9.9.265.1.1.3.1.3ColumncePfePerfIntervalEfficiencyread-onlycurrentThe percentage of processor efficiency by the PFE pipeline during this completed 15 min interval. Under normal conditions, this number will be 100 and when eff…
1.3.6.1.4.1.9.9.265.1.1.4TablecePfePerfTotalTablenot-accessiblecurrentThis table contains the running utilization and efficiency of the PFE pipeline for the 24 hour period preceding the current interval. If the agent was restarte…
1.3.6.1.4.1.9.9.265.1.1.4.1RowcePfePerfTotalEntrynot-accessiblecurrentAn entry containing performance information applicable to a particular PFE pipeline at the end of each interval in the cePfePerfIntervalTable.
1.3.6.1.4.1.9.9.265.1.1.4.1.1ColumncePfePerfTotalUtilizationread-onlycurrentThe running utilization by the PFE pipeline for the prece- ding 24 hrs.
1.3.6.1.4.1.9.9.265.1.1.4.1.2ColumncePfePerfTotalEfficiencyread-onlycurrentThe running efficiency by the PFE pipeline for the preceding 24 hrs. Under normal conditions, this number will be 100 and when efficiency starts degrading, it …
1.3.6.1.4.1.9.9.265.1.2NodecePfeHistory
1.3.6.1.4.1.9.9.265.1.2.1ScalarcePfeHistNotifiesEnableread-writecurrentThis object indicates what type of action should be taken by the agent when a event is generated.
1.3.6.1.4.1.9.9.265.1.2.2ScalarcePfeHistTableSizeread-writecurrentThis object specifies the number of entries that the cePfeHistTable can contain. When a event is generated, and the capacity of the cePfeHistTable has reached …
1.3.6.1.4.1.9.9.265.1.2.3ScalarcePfeHistTableLastIndexread-onlycurrentThis object specifies the value of the cePfeHistIndex object corresponding to the last entry added to the table by the agent. It will return zero if there are …
1.3.6.1.4.1.9.9.265.1.2.4TablecePfeHistTablenot-accessiblecurrentThis table contains a history of events generated by the agent.
1.3.6.1.4.1.9.9.265.1.2.4.1RowcePfeHistEntrynot-accessiblecurrentAn entry will exist for each event that has occured while cePfeHistNotifiesEnable object is set to 'log(2)' or 'logAndNotify(4)'.
1.3.6.1.4.1.9.9.265.1.2.4.1.1ColumncePfeHistIndexnot-accessiblecurrentAn integer value uniquely identifying the entry in the table. The value of this object starts at '1' and monotonically increases for each event condition trans…
1.3.6.1.4.1.9.9.265.1.2.4.1.2ColumncePfeHistEntPhysIndexread-onlycurrentThe value in this object is equal to the value of the entPhysicalIndex, from the Physical Entity Table (RFC 2037), that is associated with the PFE pipeline tha…
1.3.6.1.4.1.9.9.265.1.2.4.1.3ColumncePfeHistTyperead-onlycurrentThis object describes the type of event that has occurred.
1.3.6.1.4.1.9.9.265.1.2.4.1.4ColumncePfeHistThldread-onlycurrentThe configured value of the specific threshold.
1.3.6.1.4.1.9.9.265.1.2.4.1.5ColumncePfeHistValueread-onlycurrentThe actual value of the specific performance objects, at the time of the sample, which is related to the threshold event.
1.3.6.1.4.1.9.9.265.1.2.4.1.6ColumncePfeHistRestartReasonread-onlycurrentThe reason for which the PFE pipeline has restarted.
1.3.6.1.4.1.9.9.265.1.2.4.1.7ColumncePfeHistTimeStampread-onlycurrentThis object specifies the value of the sysUpTime object at the time the event was generated.
1.3.6.1.4.1.9.9.265.2NodecePfeMIBConformance
1.3.6.1.4.1.9.9.265.2.1NodecePfeMIBCompliances
1.3.6.1.4.1.9.9.265.2.1.1CompliancecePfeMIBPerformanceCompliancecurrentAn Entity-MIB implementation can implement this module to provide PFE pipeline performance history.
1.3.6.1.4.1.9.9.265.2.2NodecePfeMIBGroups
1.3.6.1.4.1.9.9.265.2.2.1GroupcePfeMIBPerformanceGroupcurrentThe collection of objects which are used to manage the per- formance history of the PFE pipeline.
1.3.6.1.4.1.9.9.265.2.2.2GroupcePfeMIBCurrentGroupcurrentThe collection of objects which are used to maintain the PFE processor's performance history over a 24 hour of operation.
1.3.6.1.4.1.9.9.265.2.2.3GroupcePfeMIBIntervalGroupcurrentThe collection of objects which are used to maintain the PFE processor's performance history over a 24 hour of operation.
1.3.6.1.4.1.9.9.265.2.2.4GroupcePfeMIBTotalGroupcurrentThe collection of objects which are used to manage the threshold configuration for the PFE pipeline performance.
1.3.6.1.4.1.9.9.265.2.2.5GroupcePfeMIBHistGroupcurrentThe collection of objects which are used to manage the threshold configuration for the PFE pipeline performance.
1.3.6.1.4.1.9.9.265.2.2.6GroupcePfeMIBHistEventGroupcurrentThe collection of objects which are used to generate a threshold event for the PFE pipeline performance.
Type Definitions
NameSyntaxStatusDescription
CurrentEfficiencyGauge32 (0..100)currentA percentage value that represents the actual efficiency performance measurement.
CurrentUtilizationGauge32 (0..100)currentA percentage value that represent the actual utilization performance measurement.
EventTypeINTEGER { none(1), log(2), notify(3), logAndNotify(4) }currentType of action to execute when an event occurs. 'none' Neither log an entry in the cePfeHistTable, nor sent out an SNMP notification. 'log' Create a cePfeHistTable entry, but do not sent out an SNMP notification. 'notif…
HistEventTypeINTEGER { thldUtilizationEvent(1), thldEfficiencyEvent(2), thld1MinUtilizationEvent(3), thld1MinEfficiencyEvent(4), thld5MinUtilizationEvent(5), thld5MinEfficiencyEvent(6), restartEvent(7) }currentType of event that has occurred. 'thldUtilizationEvent' This event is generated if the cePfePerfCurrentUtilization, at the time of sampling, becomes greater than or equal to the cePfePerfThldUtilization. 'thldEfficiency…
IntervalEfficiencyGauge32 (0..100)currentA percentage value that represents the efficiency performance measurement in a previous 15 minute measurement interval. In the case where the agent has no valid data available for a particular interval the corresponding…
IntervalUtilizationGauge32 (0..100)currentA percentage value that represents the utilization perfor- mance measurement in a previous 15 minute measurement interval. In the case where the agent has no valid data available for a particular interval the correspond…
PercentageUnsigned32 (0..100)currentA percentage value.
TotalEfficiencyGauge32 (0..100)currentA percentage value that represents the total running Effi- ciency performance measurements.
TotalUtilizationGauge32 (0..100)currentA percentage value that represents the total running utili- zation performance measurements.