CISCO-ENTITY-SENSOR-HISTORY-MIB
22 objects
This MIB module defines objects that describe collections and measurement information for each sensor supporting historical data collection. The sensor measurement either represents a measured value or a SMA (Simple Moving Average) value for a specified interval rate over a period of time. This MIB module defines two tables relating to sensor measured value, including: o ceshCollectionTable - contains data describing a collection of historic data for a sensor. o ceshCollectionIntervalTable - contains zero or more rows containing historic data for a sensor The figure below illustrates the relationship between these two tables. + | ceshCollectionTable | | + | | ceshCollectionEntry | | | | entPhysicalIndex = 3 | | | | ceshCollectionIntervalTime = 60 | | | | ceshCollectionIntervals = 60 | | | | ceshCollectionInvalidIntervals = 0 | | | ceshCollectionMaxIntervals = 60 | | | | | ceshCollectionElapsedTime = 20 | | | | | ceshCollectionAlgorithm = 3 | | | | + | + | | ceshCollectionEntry | | | | | entPhysicalIndex = 3 | | | | | ceshCollectionIntervalTime = 3660 | | | | | ceshCollectionIntervals = 2 | | | ceshCollectionInvalidIntervals = 0 | | | | | | ceshCollectionMaxIntervals = 60 | | | | | | ceshCollectionElapsedTime = 20 | | | | | | ceshCollectionAlgorithm = 4 | | | | | + + | | + | ceshCollectionIntervalTable | | | | + | | ceshCollectionIntervalEntry | | | | | | entPhysicalIndex = 3 |< | | ceshCollectionIntervalTime = 60 | | | | | | ceshCollectionIntervalNumber = 1 | | | | | | ceshCollectionIntervalSensorValue = 54 | | | | | | ceshCollectionIntervalTimeStamp = 1 | | | | | + | .................... < | skipped 58 entries < | .................... < | | | | | + | | ceshCollectionIntervalEntry | | | | | | entPhysicalIndex = 3 |< | | ceshCollectionIntervalTime = 60 | | | | | ceshCollectionIntervalNumber = 60 | | | | | ceshCollectionIntervalSensorValue = 54 | | | | | ceshCollectionIntervalTimeStamp = 60 | | | | + | | | | + | | ceshCollectionIntervalEntry | | | | | entPhysicalIndex = 3 |< | | ceshCollectionIntervalTime = 3660 | | | | ceshCollectionIntervalNumber = 1 | | | | ceshCollectionIntervalSensorValue = 54 | | | | ceshCollectionIntervalTimeStamp = 60 | | | + + If the system samples a sensor every minute for one collection and every hour for another, then the ceshCollectionTable contains two entries describing the two collections.
Imported Objects
| CISCO-SMI | ciscoMgmt |
| ENTITY-MIB | entPhysicalIndex |
| ENTITY-SENSOR-MIB | EntitySensorValue |
| SNMPv2-CONF | MODULE-COMPLIANCE OBJECT-GROUP |
| SNMPv2-SMI | Gauge32 MODULE-IDENTITY OBJECT-TYPE Unsigned32 |
| SNMPv2-TC | TEXTUAL-CONVENTION TimeStamp |
| OID | Name | Access | Status | Description |
|---|---|---|---|---|
| 1.3.6.1.4.1.9.9.768 | IdentityciscoEntitySensorHistoryMIB | This MIB module defines objects that describe collections and measurement information for each sensor supporting historical data collection. The sensor measure⦠| ||
| 1.3.6.1.4.1.9.9.768.0 | NodeciscoEntitySensorHistoryMIBObjects | |||
| 1.3.6.1.4.1.9.9.768.0.1 | TableceshCollectionTable | not-accessible | current | This table lists each collection of historic data maintained by the system for each supported sensor. This table has an expansion dependent relationship on the⦠|
| 1.3.6.1.4.1.9.9.768.0.1.1 | RowceshCollectionEntry | not-accessible | current | Each entry in the ceshCollectionTable contains collection attributes describing the collection. For each supported sensor, the system creates a row for each pr⦠|
| 1.3.6.1.4.1.9.9.768.0.1.1.1 | ColumnceshCollectionIntervalTime | not-accessible | current | This object indicates the length of the sampling interval for the collection. |
| 1.3.6.1.4.1.9.9.768.0.1.1.2 | ColumnceshCollectionIntervals | read-only | current | This object indicates the number of intervals for which data has been collected. |
| 1.3.6.1.4.1.9.9.768.0.1.1.3 | ColumnceshCollectionInvalidIntervals | read-only | current | This object indicates the number of intervals in the range of '0' to the value of the corresponding instance of ceshCollectionIntervals, for which no data is a⦠|
| 1.3.6.1.4.1.9.9.768.0.1.1.4 | ColumnceshCollectionMaxIntervals | read-only | current | This object indicates the maximum number of intervals maintained for the collection. |
| 1.3.6.1.4.1.9.9.768.0.1.1.5 | ColumnceshCollectionElapsedTime | read-only | current | This object indicates the time that has elapsed since the beginning of the current interval. |
| 1.3.6.1.4.1.9.9.768.0.1.1.6 | ColumnceshCollectionAlgorithm | read-only | current | This object indicates the algorithm used in collecting historic data from the corresponding sensor. |
| 1.3.6.1.4.1.9.9.768.0.2 | TableceshCollectionIntervalTable | not-accessible | current | This table contains the historic data for each collection maintained by the system. This table has an expansion dependent relationship on the ceshCollectionTab⦠|
| 1.3.6.1.4.1.9.9.768.0.2.1 | RowceshCollectionIntervalEntry | not-accessible | current | An entry describes the data collected for an interval. The system creates a row in the ceshCollectionIntervalTable after it has sampled a sample for a given co⦠|
| 1.3.6.1.4.1.9.9.768.0.2.1.1 | ColumnceshCollectionIntervalNumber | not-accessible | current | This object indicates the interval number identifying the interval. The interval identified by the value '1' represents the most recent interval, and the inter⦠|
| 1.3.6.1.4.1.9.9.768.0.2.1.2 | ColumnceshCollectionIntervalSensorValue | read-only | current | This object indicates the sensor value for the corresponding physical entity during the interval. To correctly display or interpret this variable's value, you ⦠|
| 1.3.6.1.4.1.9.9.768.0.2.1.3 | ColumnceshCollectionIntervalTimeStamp | read-only | current | This object indicates the value of sysUpTime when the system sampled the corresponding sensor. |
| 1.3.6.1.4.1.9.9.768.1 | NodeciscoEntitySensorHistoryMIBConform | |||
| 1.3.6.1.4.1.9.9.768.1.1 | NodeciscoEntitySensorHistoryMIBCompliances | |||
| 1.3.6.1.4.1.9.9.768.1.1.1 | ComplianceciscoEntitySensorHistoryCompliance | current | Describes the requirements for conformance to the Entity Sensor History Collection MIB module. | |
| 1.3.6.1.4.1.9.9.768.1.2 | NodeciscoEntitySensorHistoryMIBGroups | |||
| 1.3.6.1.4.1.9.9.768.1.2.1 | GroupceshCollectionGroup | current | This group contains collection of attribute objects related to entity sensor history collection | |
| 1.3.6.1.4.1.9.9.768.1.2.2 | GroupceshCollectionIntervalGroup | current | This group contains collection of interval objects related to entity sensor history collection |
Type Definitions
| Name | Syntax | Status | Description |
|---|---|---|---|
| SensorHistoryCollectionAlgorithm | INTEGER { other(1), unknown(2), measured(3), algoSMA(4) } | current | This textual convention denotes an enumerated integer-value that describing the method used to collect historic data for a sensor. 'other' - The implementation of the MIB module using this textual convention does not re⦠|