This MIB module defines objects that describe collections and measurement information for each sensor supporting historical data collection. The sensor measurement either represents a measured value or a SMA (Simple Moving Average) value for a specified interval rate over a period of time. This MIB module defines two tables relating to sensor measured value, including: o ceshCollectionTable - contains data describing a collection of historic data for a sensor. o ceshCollectionIntervalTable - contains zero or more rows containing historic data for a sensor The figure below illustrates the relationship between these two tables. + | ceshCollectionTable | | + | | ceshCollectionEntry | | | | entPhysicalIndex = 3 | | | | ceshCollectionIntervalTime = 60 | | | | ceshCollectionIntervals = 60 | | | | ceshCollectionInvalidIntervals = 0 | | | ceshCollectionMaxIntervals = 60 | | | | | ceshCollectionElapsedTime = 20 | | | | | ceshCollectionAlgorithm = 3 | | | | + | + | | ceshCollectionEntry | | | | | entPhysicalIndex = 3 | | | | | ceshCollectionIntervalTime = 3660 | | | | | ceshCollectionIntervals = 2 | | | ceshCollectionInvalidIntervals = 0 | | | | | | ceshCollectionMaxIntervals = 60 | | | | | | ceshCollectionElapsedTime = 20 | | | | | | ceshCollectionAlgorithm = 4 | | | | | + + | | + | ceshCollectionIntervalTable | | | | + | | ceshCollectionIntervalEntry | | | | | | entPhysicalIndex = 3 |< | | ceshCollectionIntervalTime = 60 | | | | | | ceshCollectionIntervalNumber = 1 | | | | | | ceshCollectionIntervalSensorValue = 54 | | | | | | ceshCollectionIntervalTimeStamp = 1 | | | | | + | .................... < | skipped 58 entries < | .................... < | | | | | + | | ceshCollectionIntervalEntry | | | | | | entPhysicalIndex = 3 |< | | ceshCollectionIntervalTime = 60 | | | | | ceshCollectionIntervalNumber = 60 | | | | | ceshCollectionIntervalSensorValue = 54 | | | | | ceshCollectionIntervalTimeStamp = 60 | | | | + | | | | + | | ceshCollectionIntervalEntry | | | | | entPhysicalIndex = 3 |< | | ceshCollectionIntervalTime = 3660 | | | | ceshCollectionIntervalNumber = 1 | | | | ceshCollectionIntervalSensorValue = 54 | | | | ceshCollectionIntervalTimeStamp = 60 | | | + + If the system samples a sensor every minute for one collection and every hour for another, then the ceshCollectionTable contains two entries describing the two collections.
Imported Objects
CISCO-SMIciscoMgmt
ENTITY-MIBentPhysicalIndex
ENTITY-SENSOR-MIBEntitySensorValue
SNMPv2-CONFMODULE-COMPLIANCE OBJECT-GROUP
SNMPv2-SMIGauge32 MODULE-IDENTITY OBJECT-TYPE Unsigned32
SNMPv2-TCTEXTUAL-CONVENTION TimeStamp
OIDNameAccessStatusDescription
1.3.6.1.4.1.9.9.768IdentityciscoEntitySensorHistoryMIBThis MIB module defines objects that describe collections and measurement information for each sensor supporting historical data collection. The sensor measure…
1.3.6.1.4.1.9.9.768.0NodeciscoEntitySensorHistoryMIBObjects
1.3.6.1.4.1.9.9.768.0.1TableceshCollectionTablenot-accessiblecurrentThis table lists each collection of historic data maintained by the system for each supported sensor. This table has an expansion dependent relationship on the…
1.3.6.1.4.1.9.9.768.0.1.1RowceshCollectionEntrynot-accessiblecurrentEach entry in the ceshCollectionTable contains collection attributes describing the collection. For each supported sensor, the system creates a row for each pr…
1.3.6.1.4.1.9.9.768.0.1.1.1ColumnceshCollectionIntervalTimenot-accessiblecurrentThis object indicates the length of the sampling interval for the collection.
1.3.6.1.4.1.9.9.768.0.1.1.2ColumnceshCollectionIntervalsread-onlycurrentThis object indicates the number of intervals for which data has been collected.
1.3.6.1.4.1.9.9.768.0.1.1.3ColumnceshCollectionInvalidIntervalsread-onlycurrentThis object indicates the number of intervals in the range of '0' to the value of the corresponding instance of ceshCollectionIntervals, for which no data is a…
1.3.6.1.4.1.9.9.768.0.1.1.4ColumnceshCollectionMaxIntervalsread-onlycurrentThis object indicates the maximum number of intervals maintained for the collection.
1.3.6.1.4.1.9.9.768.0.1.1.5ColumnceshCollectionElapsedTimeread-onlycurrentThis object indicates the time that has elapsed since the beginning of the current interval.
1.3.6.1.4.1.9.9.768.0.1.1.6ColumnceshCollectionAlgorithmread-onlycurrentThis object indicates the algorithm used in collecting historic data from the corresponding sensor.
1.3.6.1.4.1.9.9.768.0.2TableceshCollectionIntervalTablenot-accessiblecurrentThis table contains the historic data for each collection maintained by the system. This table has an expansion dependent relationship on the ceshCollectionTab…
1.3.6.1.4.1.9.9.768.0.2.1RowceshCollectionIntervalEntrynot-accessiblecurrentAn entry describes the data collected for an interval. The system creates a row in the ceshCollectionIntervalTable after it has sampled a sample for a given co…
1.3.6.1.4.1.9.9.768.0.2.1.1ColumnceshCollectionIntervalNumbernot-accessiblecurrentThis object indicates the interval number identifying the interval. The interval identified by the value '1' represents the most recent interval, and the inter…
1.3.6.1.4.1.9.9.768.0.2.1.2ColumnceshCollectionIntervalSensorValueread-onlycurrentThis object indicates the sensor value for the corresponding physical entity during the interval. To correctly display or interpret this variable's value, you …
1.3.6.1.4.1.9.9.768.0.2.1.3ColumnceshCollectionIntervalTimeStampread-onlycurrentThis object indicates the value of sysUpTime when the system sampled the corresponding sensor.
1.3.6.1.4.1.9.9.768.1NodeciscoEntitySensorHistoryMIBConform
1.3.6.1.4.1.9.9.768.1.1NodeciscoEntitySensorHistoryMIBCompliances
1.3.6.1.4.1.9.9.768.1.1.1ComplianceciscoEntitySensorHistoryCompliancecurrentDescribes the requirements for conformance to the Entity Sensor History Collection MIB module.
1.3.6.1.4.1.9.9.768.1.2NodeciscoEntitySensorHistoryMIBGroups
1.3.6.1.4.1.9.9.768.1.2.1GroupceshCollectionGroupcurrentThis group contains collection of attribute objects related to entity sensor history collection
1.3.6.1.4.1.9.9.768.1.2.2GroupceshCollectionIntervalGroupcurrentThis group contains collection of interval objects related to entity sensor history collection
Type Definitions
NameSyntaxStatusDescription
SensorHistoryCollectionAlgorithmINTEGER { other(1), unknown(2), measured(3), algoSMA(4) }currentThis textual convention denotes an enumerated integer-value that describing the method used to collect historic data for a sensor. 'other' - The implementation of the MIB module using this textual convention does not re…