CISCO-ENTITY-SENSOR-MIB
50 objects
The CISCO-ENTITY-SENSOR-MIB is used to monitor the values of sensors in the Entity-MIB (RFC 2037) entPhysicalTable.
Imported Objects
| CISCO-SMI | ciscoMgmt |
| CISCO-TC | EntPhysicalIndexOrZero |
| ENTITY-MIB | entPhysicalIndex |
| SNMPv2-CONF | MODULE-COMPLIANCE NOTIFICATION-GROUP OBJECT-GROUP |
| SNMPv2-SMI | Integer32 MODULE-IDENTITY NOTIFICATION-TYPE OBJECT-TYPE |
| SNMPv2-TC | TEXTUAL-CONVENTION TimeStamp TruthValue |
| OID | Name | Access | Status | Description |
|---|---|---|---|---|
| 1.3.6.1.4.1.9.9.91 | IdentityciscoEntitySensorMIB | read-write | The CISCO-ENTITY-SENSOR-MIB is used to monitor the values of sensors in the Entity-MIB (RFC 2037) entPhysicalTable. | |
| 1.3.6.1.4.1.9.9.91.1 | NodeentitySensorMIBObjects | |||
| 1.3.6.1.4.1.9.9.91.1.1 | NodeentSensorValues | |||
| 1.3.6.1.4.1.9.9.91.1.1.1 | TableentSensorValueTable | not-accessible | current | This table lists the type, scale, and present value of a sensor listed in the Entity-MIB entPhysicalTable. |
| 1.3.6.1.4.1.9.9.91.1.1.1.1 | RowentSensorValueEntry | not-accessible | current | An entSensorValueTable entry describes the present reading of a sensor, the measurement units and scale, and sensor operational status. |
| 1.3.6.1.4.1.9.9.91.1.1.1.1.1 | ColumnentSensorType | read-only | current | This variable indicates the type of data reported by the entSensorValue. This variable is set by the agent at start-up and the value does not change during ope… |
| 1.3.6.1.4.1.9.9.91.1.1.1.1.2 | ColumnentSensorScale | read-only | current | This variable indicates the exponent to apply to sensor values reported by entSensorValue. This variable is set by the agent at start-up and the value does not… |
| 1.3.6.1.4.1.9.9.91.1.1.1.1.3 | ColumnentSensorPrecision | read-only | current | This variable indicates the number of decimal places of precision in fixed-point sensor values reported by entSensorValue. This variable is set to 0 when entSe… |
| 1.3.6.1.4.1.9.9.91.1.1.1.1.4 | ColumnentSensorValue | read-only | current | This variable reports the most recent measurement seen by the sensor. To correctly display or interpret this variable's value, you must also know entSensorType… |
| 1.3.6.1.4.1.9.9.91.1.1.1.1.5 | ColumnentSensorStatus | read-only | current | This variable indicates the present operational status of the sensor. |
| 1.3.6.1.4.1.9.9.91.1.1.1.1.6 | ColumnentSensorValueTimeStamp | read-only | current | This variable indicates the age of the value reported by entSensorValue |
| 1.3.6.1.4.1.9.9.91.1.1.1.1.7 | ColumnentSensorValueUpdateRate | read-only | current | This variable indicates the rate that the agent updates entSensorValue. |
| 1.3.6.1.4.1.9.9.91.1.1.1.1.8 | ColumnentSensorMeasuredEntity | read-only | current | This object identifies the physical entity for which the sensor is taking measurements. For example, for a sensor measuring the voltage output of a power-suppl… |
| 1.3.6.1.4.1.9.9.91.1.2 | NodeentSensorThresholds | |||
| 1.3.6.1.4.1.9.9.91.1.2.1 | TableentSensorThresholdTable | not-accessible | current | This table lists the threshold severity, relation, and comparison value, for a sensor listed in the Entity-MIB entPhysicalTable. |
| 1.3.6.1.4.1.9.9.91.1.2.1.1 | RowentSensorThresholdEntry | not-accessible | current | An entSensorThresholdTable entry describes the thresholds for a sensor: the threshold severity, the threshold value, the relation, and the evaluation of the th… |
| 1.3.6.1.4.1.9.9.91.1.2.1.1.1 | ColumnentSensorThresholdIndex | not-accessible | current | An index that uniquely identifies an entry in the entSensorThresholdTable. This index permits the same sensor to have several different thresholds. |
| 1.3.6.1.4.1.9.9.91.1.2.1.1.2 | ColumnentSensorThresholdSeverity | read-write | current | This variable indicates the severity of this threshold. |
| 1.3.6.1.4.1.9.9.91.1.2.1.1.3 | ColumnentSensorThresholdRelation | read-write | current | This variable indicates the relation between sensor value (entSensorValue) and threshold value (entSensorThresholdValue), required to trigger the alarm. when e… |
| 1.3.6.1.4.1.9.9.91.1.2.1.1.4 | ColumnentSensorThresholdValue | read-write | current | This variable indicates the value of the threshold. To correctly display or interpret this variable's value, you must also know entSensorType, entSensorScale, … |
| 1.3.6.1.4.1.9.9.91.1.2.1.1.5 | ColumnentSensorThresholdEvaluation | read-only | current | This variable indicates the result of the most recent evaluation of the threshold. If the threshold condition is true, entSensorThresholdEvaluation is true(1).… |
| 1.3.6.1.4.1.9.9.91.1.2.1.1.6 | ColumnentSensorThresholdNotificationEnable | read-write | current | This variable controls generation of entSensorThresholdNotification for this threshold. When this variable is 'true', generation of entSensorThresholdNotificat… |
| 1.3.6.1.4.1.9.9.91.1.3 | NodeentSensorGlobalObjects | |||
| 1.3.6.1.4.1.9.9.91.1.3.1 | ScalarentSensorThreshNotifGlobalEnable | read-write | current | This variable enables the generation of entSensorThresholdNotification globally on the device. If this object value is 'false', then no entSensorThresholdNotif… |
| 1.3.6.1.4.1.9.9.91.2 | NodeentitySensorMIBNotificationPrefix | |||
| 1.3.6.1.4.1.9.9.91.2.0 | NodeentitySensorMIBNotifications | |||
| 1.3.6.1.4.1.9.9.91.2.0.1 | NotificationentSensorThresholdNotification | current | The notification is generated when the sensor value entSensorValue crosses the threshold value entSensorThresholdValue and the value of entSensorThreshNotifGlo… | |
| 1.3.6.1.4.1.9.9.91.2.0.2 | NotificationentSensorThresholdRecoveryNotification | current | This notification is generated as a recovery notification when the sensor value entSensorValue goes below the threshold value entSensorThresholdValue once it h… | |
| 1.3.6.1.4.1.9.9.91.3 | NodeentitySensorMIBConformance | |||
| 1.3.6.1.4.1.9.9.91.3.1 | NodeentitySensorMIBCompliances | |||
| 1.3.6.1.4.1.9.9.91.3.1.1 | ComplianceentitySensorMIBComplianceV01 | deprecated | An Entity-MIB implementation that lists sensors in its entPhysicalTable must implement this group. | |
| 1.3.6.1.4.1.9.9.91.3.1.2 | ComplianceentitySensorMIBComplianceV02 | read-only | deprecated | An Entity-MIB implementation that lists sensors in its entPhysicalTable must implement this group. |
| 1.3.6.1.4.1.9.9.91.3.1.3 | ComplianceentitySensorMIBComplianceV03 | read-only | deprecated | An Entity-MIB implementation that lists sensors in its entPhysicalTable must implement this group. |
| 1.3.6.1.4.1.9.9.91.3.1.4 | ComplianceentitySensorMIBComplianceV04 | read-only | deprecated | An Entity-MIB implementation that lists sensors in its entPhysicalTable must implement this group. |
| 1.3.6.1.4.1.9.9.91.3.1.5 | ComplianceentitySensorMIBComplianceV05 | read-only | current | An Entity-MIB implementation that lists sensors in its entPhysicalTable must implement this group. |
| 1.3.6.1.4.1.9.9.91.3.2 | NodeentitySensorMIBGroups | |||
| 1.3.6.1.4.1.9.9.91.3.2.1 | GroupentitySensorValueGroup | current | The collection of objects which are used to describe and monitor values of Entity-MIB entPhysicalTable entries of sensors. | |
| 1.3.6.1.4.1.9.9.91.3.2.2 | GroupentitySensorThresholdGroup | current | The collection of objects which are used to describe and monitor thresholds for sensors. | |
| 1.3.6.1.4.1.9.9.91.3.2.3 | GroupentitySensorThresholdNotificationGroup | deprecated | The collection of notifications used for monitoring sensor threshold activity. entitySensorThresholdNotificationGroup object is superseded by entitySensorNotif… | |
| 1.3.6.1.4.1.9.9.91.3.2.4 | GroupentitySensorValueGroupSup1 | current | The collection of objects which are used to describe and track the measured entities of ENTITY-MIB entPhysicalTable. | |
| 1.3.6.1.4.1.9.9.91.3.2.5 | GroupentitySensorNotifCtrlGlobalGroup | current | The collection of objects which provide the global notification control on entSensorThresholdNotification. | |
| 1.3.6.1.4.1.9.9.91.3.2.6 | GroupentitySensorNotificationGroup | current | The collection of notifications used for monitoring sensor threshold activity. |
Type Definitions
| Name | Syntax | Status | Description |
|---|---|---|---|
| SensorDataScale | INTEGER { yocto(1), zepto(2), atto(3), femto(4), pico(5), nano(6), micro(7), milli(8), units(9), kilo(10), mega(11), giga(12), tera(13), exa(14), peta(15), zetta(16), yotta(17) } | current | International System of Units (SI) prefixes. |
| SensorDataType | INTEGER { other(1), unknown(2), voltsAC(3), voltsDC(4), amperes(5), watts(6), hertz(7), celsius(8), percentRH(9), rpm(10), cmm(11), truthvalue(12), specialEnum(13), dBm(14), dB(15) } | current | sensor measurement data types. valid values are: other(1): a measure other than those listed below unknown(2): unknown measurement, or arbitrary, relative numbers voltsAC(3): electric potential voltsDC(4): electric pote… |
| SensorPrecision | INTEGER (-8..9) | current | When in the range 1 to 9, SensorPrecision is the number of decimal places in the fractional part of a SensorValue fixed-point number. When in the range -8 to -1, SensorPrecision is the number of accurate digits in a Sen… |
| SensorStatus | INTEGER { ok(1), unavailable(2), nonoperational(3) } | current | Indicates the operational status of the sensor. ok(1) means the agent can read the sensor value. unavailable(2) means that the agent presently can not report the sensor value. nonoperational(3) means that the agent beli… |
| SensorThresholdRelation | INTEGER { lessThan(1), lessOrEqual(2), greaterThan(3), greaterOrEqual(4), equalTo(5), notEqualTo(6) } | current | sensor threshold relational operator types. valid values are: lessThan(1): if the sensor value is less than the threshold value lessOrEqual(2): if the sensor value is less than or equal to the threshold value greaterTha… |
| SensorThresholdSeverity | INTEGER { other(1), minor(10), major(20), critical(30) } | current | sensor threshold severity. Valid values are: other(1) : a severity other than those listed below. minor(10) : Minor Problem threshold. major(20) : Major Problem threshold. critical(30): Critical problem threshold. A sys… |
| SensorValue | INTEGER (-1000000000..1000000000) | current | For sensors that measure voltsAC, voltsDC, amperes, watts, hertz, celsius, cmm this item is a fixed point number ranging from -999,999,999 to +999,999,999. Use the value -1000000000 to indicate underflow. Use the value … |
| SensorValueUpdateRate | INTEGER (0..999999999) | current | Indicates the interval in seconds between updates to the sensor's value. The value zero indicates: - the sensor value is updated on demand (when polled by the agent for a get-request), - or when the sensor value changes… |