MIB Viewer

CISCO-ITP-MONITOR-MIB

46 objects
The MIB for providing information related to monitoring SS7 links. This information can be used to manage the state of software used to collect all packets transported and received over a SS7 link. Abbreviations: MSU - Message Signalling Unit MTP - Message Transport Protocol SS7 - System No. 7 (SS7) Network
Imported Objects
CISCO-SMIciscoMgmt
INET-ADDRESS-MIBInetPortNumber
SNMP-FRAMEWORK-MIBSnmpAdminString
SNMPv2-CONFMODULE-COMPLIANCE NOTIFICATION-GROUP OBJECT-GROUP
SNMPv2-SMICounter32 Gauge32 MODULE-IDENTITY NOTIFICATION-TYPE OBJECT-TYPE Unsigned32
SNMPv2-TCTruthValue
OIDNameAccessStatusDescription
1.3.6.1.4.1.9.9.379IdentityciscoItpmMIBThe MIB for providing information related to monitoring SS7 links. This information can be used to manage the state of software used to collect all packets tra…
1.3.6.1.4.1.9.9.379.0NodeciscoItpmMIBNotifs
1.3.6.1.4.1.9.9.379.0.1NotificationciscoItpMonitorCongestioncurrentThe notification generated when a connection enters or exits congestion state. The value of cItpmConnCongestion indicates new state.
1.3.6.1.4.1.9.9.379.0.2NotificationciscoItpMonitorStatecurrentThe notification generated when a connection changes states. The value of cItpmConnMonitorState indicates new state.
1.3.6.1.4.1.9.9.379.1NodeciscoItpmMIBObjects
1.3.6.1.4.1.9.9.379.1.1NodecItpmConn
1.3.6.1.4.1.9.9.379.1.1.1TablecItpmConnTablenot-accessiblecurrentThis table provides information on connections used to collect information on SS7 links. Information in this table can be used to customize connection paramete…
1.3.6.1.4.1.9.9.379.1.1.1.1RowcItpmConnTableEntrynot-accessiblecurrentAn entry in the cItpmConnTable table.
1.3.6.1.4.1.9.9.379.1.1.1.1.1ColumncItpmConnPortNumbernot-accessiblecurrentThe port number used to establish TCP connection.
1.3.6.1.4.1.9.9.379.1.1.1.1.2ColumncItpmConnKeepAliveread-writecurrentSpecifies the keepalive time value in milliseconds. Keepalive packets are sent between the monitor and the remote server as a mechanism to ensure the TCP sessi…
1.3.6.1.4.1.9.9.379.1.1.1.1.3ColumncItpmConnMaxQDepthread-writecurrentThe maximum number of packets that can be queued for transmission. If the monitor cannot send a TCP packet immediately, the packet will be queued for retransmi…
1.3.6.1.4.1.9.9.379.1.1.1.1.4ColumncItpmConnCongOnsetread-writecurrentThreshold used to mark onset of congestion. When the cItpmConnQueueDepth object reaches value specified by this object the connection will considered congested…
1.3.6.1.4.1.9.9.379.1.1.1.1.5ColumncItpmConnCongAbateread-writecurrentThreshold used to mark end of congestion. When the cItpmConnQueueDepth object drops below the value specified by this object the connection will exit congestio…
1.3.6.1.4.1.9.9.379.1.1.1.1.6ColumncItpmConnRcvWindowSizeread-writecurrentThe size of TCP receive window. This object defines the number of outstanding (unacknowledged) bytes that the ITP monitor can receive on TCP connection.
1.3.6.1.4.1.9.9.379.1.1.1.1.7ColumncItpmConnFastStartread-writecurrentDefines the fast-start option for establishing TCP connectivity as follows. 'true' - FastStart is enabled. 'false' - FastStart is disabled. Normally, after the…
1.3.6.1.4.1.9.9.379.1.1.1.1.8ColumncItpmConnQueueDepthread-onlycurrentThe number of packets queued for transmission. The maximum value is specified by the cItpmConnMaxQDepth object.
1.3.6.1.4.1.9.9.379.1.1.1.1.9ColumncItpmConnMonitorStateread-onlycurrentThe state of the connection as follows. 'active' - connection is transmitting SS7 link traffic to server. 'inactive' - connection is not transmitting SS7 link …
1.3.6.1.4.1.9.9.379.1.1.1.1.10ColumncItpmConnCongestionread-onlycurrentCongestion indicator for connection as follows. 'true' - connection is congested. 'false' - connection not congested. Congestion onset occurs when the cItpmCon…
1.3.6.1.4.1.9.9.379.1.1.1.1.11ColumncItpmConnCongCountsread-onlycurrentThe number of times the connection has entered congestion.
1.3.6.1.4.1.9.9.379.1.1.2TablecItpmLinkTablenot-accessiblecurrentThis table provides information and measurements on the monitored SS7 links per connection. This table shares the cItpmConnPortNumber index with the cItpmConnT…
1.3.6.1.4.1.9.9.379.1.1.2.1RowcItpmLinkTableEntrynot-accessiblecurrentAn entry in the cItpmLinkTable table.
1.3.6.1.4.1.9.9.379.1.1.2.1.1ColumncItpmLinkNumbernot-accessiblecurrentThis object specifies the secondary index for objects in the cItpmLinkTable table. A unique number is assigned to each link when it is assigned to a connection.
1.3.6.1.4.1.9.9.379.1.1.2.1.2ColumncItpmLinkDescriptionread-onlycurrentBrief customer defined description.
1.3.6.1.4.1.9.9.379.1.1.2.1.3ColumncItpmLinkSlotNumberread-onlycurrentThe slot number support interface used to collect SS7 link traffic.
1.3.6.1.4.1.9.9.379.1.1.2.1.4ColumncItpmLinkStatusread-onlycurrentThe state of the monitored SS7 Link as follows. 'active' - SS7 link is available for monitoring. 'inactive' - SS7 link is unavailable for monitoring.
1.3.6.1.4.1.9.9.379.1.1.2.1.5ColumncItpmLinkRcvdMsusread-onlycurrentThe number of MSUs received on SS7 Link.
1.3.6.1.4.1.9.9.379.1.1.2.1.6ColumncItpmLinkRcvdMsuDropsread-onlycurrentThe number of MSUs that were received on SS7 Link and were dropped due to congestion.
1.3.6.1.4.1.9.9.379.1.1.2.1.7ColumncItpmLinkRcvdMsuRateread-onlycurrentThe number of MSUs received on SS7 Link per second.
1.3.6.1.4.1.9.9.379.1.1.2.1.8ColumncItpmLinkRcvdBitsRateread-onlycurrentThe number of bits received on SS7 Link per second.
1.3.6.1.4.1.9.9.379.1.1.2.1.9ColumncItpmLinkSentMsusread-onlycurrentThe number of MSUs sent on SS7 Link.
1.3.6.1.4.1.9.9.379.1.1.2.1.10ColumncItpmLinkSentMsuDropsread-onlycurrentThe number of MSUs that were sent on SS7 Link and were dropped due to congestion.
1.3.6.1.4.1.9.9.379.1.1.2.1.11ColumncItpmLinkSentMsuRateread-onlycurrentThe number of MSUs sent on SS7 Link per second.
1.3.6.1.4.1.9.9.379.1.1.2.1.12ColumncItpmLinkSentBitsRateread-onlycurrentThe number of bits sent on SS7 Link per second.
1.3.6.1.4.1.9.9.379.1.2NodecItpmLink
1.3.6.1.4.1.9.9.379.1.3ScalarcItpmCongestionNotifEnabledread-writecurrentThe ITP monitor congestion States notification truth value. 'true' Indicates that cItpmCongestionNotifEnabled notification is to be generated when the state ch…
1.3.6.1.4.1.9.9.379.1.4ScalarcItpmMonitorStateNotifEnabledread-writecurrentThe ITP monitor state notification truth value. 'true' - Indicates that ciscoItpMonitorState notification is to be generated when the state of connection chang…
1.3.6.1.4.1.9.9.379.2NodeciscoItpmMIBConform
1.3.6.1.4.1.9.9.379.2.1NodeciscoItpmMIBCompliances
1.3.6.1.4.1.9.9.379.2.1.1ComplianceciscoItpmMIBCompliancedeprecatedThe compliance statement for entities which implement the CISCO-ITP-MONITOR-MIB.my MIB
1.3.6.1.4.1.9.9.379.2.1.2ComplianceciscoItpmMIBComplianceRev1currentThe compliance statement for entities which implement the CISCO-ITP-MONITOR-MIB.my MIB
1.3.6.1.4.1.9.9.379.2.2NodeciscoItpmMIBGroups
1.3.6.1.4.1.9.9.379.2.2.1GroupciscoItpmConnGroupdeprecatedITP Monitor connection group.
1.3.6.1.4.1.9.9.379.2.2.2GroupciscoItpmLinkGroupcurrentITP Monitor SS7 Link group
1.3.6.1.4.1.9.9.379.2.2.3GroupciscoItpmNotificationsGroupdeprecatedITP Monitor notification objects.
1.3.6.1.4.1.9.9.379.2.2.4GroupciscoItpmConnGroupRev1currentITP Monitor connection group
1.3.6.1.4.1.9.9.379.2.2.5GroupciscoItpmNotificationsGroupRev1currentITP Monitor notification objects.