MIB Viewer

CISCO-MGX82XX-DSX3-BERT-MIB

27 objects
The MIB Module for BERT (Bit Error Rate Testing) on ds3 interfaces in some of the cards (Service Modules) in MGX products. This MIB is applicable for following T3/E3 Service Modules: FRSM-2T3E3 : Frame Relay Service Module. CESM-T3E3 : Circuit Emulation Service Module.
Imported Objects
BASIS-MIBaxisDiagnostics
CISCOWAN-SMIciscoWan
SNMPv2-CONFMODULE-COMPLIANCE OBJECT-GROUP
SNMPv2-SMIInteger32 MODULE-IDENTITY OBJECT-TYPE
SNMPv2-TCDisplayString
OIDNameAccessStatusDescription
1.3.6.1.4.1.351.110.6.2Nodedsx3bert
1.3.6.1.4.1.351.110.6.2.1Scalardsx3bertControlread-writecurrentThis object controls all the SET operations on this MIB group. noAction : No action is taken. This value can not be written This object contains value noAction…
1.3.6.1.4.1.351.110.6.2.2Scalardsx3bertResourceStatusread-onlycurrentAll of bert resources can be used by only one user at a time. This object provides the status of the resources.
1.3.6.1.4.1.351.110.6.2.3Scalardsx3bertOwnerread-onlycurrentThis refers to the user who owns the BERT resources. If the user is a CLI user, then this is username. If it is SNMP Manager, then this would be the ASCII form…
1.3.6.1.4.1.351.110.6.2.4Scalardsx3bertUserIdread-writecurrentThis identifies the user who wants to do a SET operation on this group. This will be compared against bertOwner and access will be given only if it matches. He…
1.3.6.1.4.1.351.110.6.2.5Scalardsx3bertStatusread-onlycurrentThis object provides the status of BERT in the shelf. The possible values are : inactive (1) : BERT not in progress bertInSync (2) : BERT is activated and rece…
1.3.6.1.4.1.351.110.6.2.6Scalardsx3bertTestMediumread-writecurrentSpecifies whether the BERT is to be tested on a port or an entire T3/E3 line. For a BERT test, this object must be set. For CESM-T3E3 and FRSM-@T3E3, this obje…
1.3.6.1.4.1.351.110.6.2.7Scalardsx3bertPortread-writecurrentThis object specifies the port number for BERT. Port level bert is not supported in CESM-T3E3 and FRSM-2T3E3. So for these cards, the value must be always 1.
1.3.6.1.4.1.351.110.6.2.8Scalardsx3bertLineread-writecurrentThis object specifies the line number for BERT. If the dsx3bertTestMedium is set to port(1), this represents the line to which the port (dsx3bertPort) belongs.…
1.3.6.1.4.1.351.110.6.2.9Scalardsx3bertModeread-writecurrentThis object specifies the mode, the BERT module is to be configured for. The value loopback(2) is not supported in CESM-T3E3 and FRSM-2T3E3 .
1.3.6.1.4.1.351.110.6.2.10Scalardsx3bertPatternread-writecurrentThis variable determines BERT pattern to be transmitted on the interface identified by dsx3bertLine or dsx3bertPort. Bit error measurements are widely used to …
1.3.6.1.4.1.351.110.6.2.11Scalardsx3bertLoopbackread-writecurrentThis object specifies the type of loopback to be established/de-established. The value farEndLoopback(1) is not supported in CESM-T3E3 and FRSM-2T3E3, where th…
1.3.6.1.4.1.351.110.6.2.12Scalardsx3bertStartTimeread-onlycurrentThis object contains the time at which BERT started. The syntax is hh:mm:ss. The time zone is as configured in the shelf. This object contains zero length stri…
1.3.6.1.4.1.351.110.6.2.13Scalardsx3bertStartDateread-onlycurrentThis object contains the date on which BERT started. The syntax is yy/mm/dd. This object contains zero length string for following values of dsx3bertControl: n…
1.3.6.1.4.1.351.110.6.2.14Scalardsx3bertBitCountUpperread-onlycurrentThis number of bits transmitted is represented in an encoded form as a 64-bit counter. This object gives the upper 31 bits of the 64 bit counter. The 32nd bit …
1.3.6.1.4.1.351.110.6.2.15Scalardsx3bertBitCountLowerread-onlycurrentThis number of bits transmitted is represented in an encoded form as a 64-bit counter. This object gives the lower 31 bits of the 64 bit counter. The 32nd bit …
1.3.6.1.4.1.351.110.6.2.16Scalardsx3bertBitErrorCountUpperread-onlycurrentThis number of bits received in error is represented in an encoded form as a 64-bit counter. This object gives the upper 31 bits of the 64 bit counter. The 32n…
1.3.6.1.4.1.351.110.6.2.17Scalardsx3bertBitErrorCountLowerread-onlycurrentThis number of bits received in error is represented in an encoded form as a 64-bit counter. This object gives the lower 31 bits of the 64 bit counter. The 32n…
1.3.6.1.4.1.351.110.6.2.18Scalardsx3bertErrorInsertionRateread-writecurrentThis object is used for injecting continuous errors into transmitted BERT pattern. The errors are inserted in a BERT pattern sent, in order to do sanity check …
1.3.6.1.4.1.351.110.6.2.19Scalardsx3bertErrorInjectCountread-onlycurrentThis shows the number of times error was injected.
1.3.6.1.4.1.351.110.6.2.20Scalardsx3bertCleanupActionread-onlycurrentWhen the BERT has to be stopped or aborted (due to card state changes), this object would give the exact action to take. The bert related changes to the card, …
1.3.6.1.4.1.351.150.39IdentityciscoMgx82xxDsx3BertMIBThe MIB Module for BERT (Bit Error Rate Testing) on ds3 interfaces in some of the cards (Service Modules) in MGX products. This MIB is applicable for following…
1.3.6.1.4.1.351.150.39.2NodecmDsx3BertMIBConformance
1.3.6.1.4.1.351.150.39.2.1NodecmDsx3BertMIBGroups
1.3.6.1.4.1.351.150.39.2.1.1GroupcmDsx3BertConfGroupcurrentThe collection of objects which are used for configuring/running BERT on DSX3 interfaces.
1.3.6.1.4.1.351.150.39.2.2NodecmDsx3BertMIBCompliances
1.3.6.1.4.1.351.150.39.2.2.1CompliancecmDsx3BertCompliancecurrentThe compliance statement for objects related to Bert MIB.