MIB Viewer

CISCO-VOICE-APPS-MIB

33 objects
The MIB Module for the management of Cisco Voice Applications. This MIB is designed to work in conjunction with the SYSAPPL-MIB to provide status monitoring, provisioning and notification.
Imported Objects
CISCO-SMIciscoMgmt
SNMP-FRAMEWORK-MIBSnmpAdminString
SNMPv2-CONFMODULE-COMPLIANCE NOTIFICATION-GROUP OBJECT-GROUP
SNMPv2-SMIMODULE-IDENTITY NOTIFICATION-TYPE OBJECT-TYPE Unsigned32
SNMPv2-TCDisplayString TruthValue
OIDNameAccessStatusDescription
1.3.6.1.4.1.9.9.190IdentityciscoVoiceAppsMIBThe MIB Module for the management of Cisco Voice Applications. This MIB is designed to work in conjunction with the SYSAPPL-MIB to provide status monitoring, p…
1.3.6.1.4.1.9.9.190.1NodeciscoVoiceAppsMIBObjects
1.3.6.1.4.1.9.9.190.1.1NodecvaGeneralInfo
1.3.6.1.4.1.9.9.190.1.1.1TablecvaWorkflowInstallTablenot-accessiblecurrentThe table containing the list of installed Workflow applications provisioned on the media server. For instance, this table may contain an entry for each of the…
1.3.6.1.4.1.9.9.190.1.1.1.1RowcvaWorkflowInstallEntrynot-accessiblecurrentAn entry (conceptual row) in the Workflow Installation Table, containing information associated with the Cisco Workflow Application. This entry is created when…
1.3.6.1.4.1.9.9.190.1.1.1.1.1ColumncvaWorkflowInstallIndexnot-accessiblecurrentAn arbitrary integer which uniquely identifies an Workflow Application.
1.3.6.1.4.1.9.9.190.1.1.1.1.2ColumncvaWorkflowInstallNameread-onlycurrentThe name of the workflow application.
1.3.6.1.4.1.9.9.190.1.1.1.1.3ColumncvaWorkflowInstallLocatorread-onlycurrentThe extension number or CTI (Computer Telephony Integration) route point associated with the workflow application. For instance, 5000 for extension 5000.
1.3.6.1.4.1.9.9.190.1.1.1.1.4ColumncvaWorkflowInstallScriptNameread-onlycurrentThe workflow application script name.
1.3.6.1.4.1.9.9.190.1.1.1.1.5ColumncvaWorkflowInstallEnableread-onlycurrentThe status of the workflow application. true(1): Workflow Application is enabled false(2): Workflow Application is disabled.
1.3.6.1.4.1.9.9.190.1.1.3ScalarcvaNotificationEnableread-writecurrentTo enable(1) or disable(2) generation of the following notifications: cvaModuleStart notification cvaModuleStop notification cvaModuleRunTimeFailure notificati…
1.3.6.1.4.1.9.9.190.1.2NodecvaModuleFailureInfo
1.3.6.1.4.1.9.9.190.1.2.1ScalarcvaAlarmSeverityaccessible-for-notifycurrentThe application alarm notification severity code. emergency: System unusable alert: Immediate response needed critical: Critical condition error: Error conditi…
1.3.6.1.4.1.9.9.190.1.2.2ScalarcvaModuleNameaccessible-for-notifycurrentThe application module or subsystem name.
1.3.6.1.4.1.9.9.190.1.2.3ScalarcvaProcessIdaccessible-for-notifycurrentA unique value for each of the process running on the host. Wherever possible, this should be the system's native, unique Identification number (process id).
1.3.6.1.4.1.9.9.190.1.2.4ScalarcvaModuleFailureNameaccessible-for-notifycurrentThe application module name which causes the failure.
1.3.6.1.4.1.9.9.190.1.2.5ScalarcvaModuleFailureCauseaccessible-for-notifycurrentThe application module failure cause code. This is used by cvaModuleStop to indicate reason of module stop if known. other: Other unspecified failure cause gra…
1.3.6.1.4.1.9.9.190.1.2.6ScalarcvaModuleFailureMessageaccessible-for-notifycurrentThe application module failure message.
1.3.6.1.4.1.9.9.190.1.2.7ScalarcvaModuleRunTimeFailureCauseaccessible-for-notifycurrentThe application module run-time failure cause code. other: Other or unspecified failure readAccessFailure: Read Access failure writeAccessFailure: Write Access…
1.3.6.1.4.1.9.9.190.2NodeciscoVoiceAppsMIBNotificationPrefix
1.3.6.1.4.1.9.9.190.2.0NodeciscoVoiceAppsMIBNotifications
1.3.6.1.4.1.9.9.190.2.0.1NotificationcvaModuleStartcurrentA cvaModuleStart notification signifies that an application module or subsystem has successfully started and transitioned into in-service state. This notificat…
1.3.6.1.4.1.9.9.190.2.0.2NotificationcvaModuleStopcurrentA cvaModuleStop notification signifies that an application module or subsystem has stopped. This notification is working in conjunction with the cvaModuleStart…
1.3.6.1.4.1.9.9.190.2.0.3NotificationcvaModuleRunTimeFailurecurrentA cvaModuleRunTimeFailure notification signifies that a run time failure has occurred. If failure cause is known then it will be specified in the cvaModuleRunT…
1.3.6.1.4.1.9.9.190.2.0.4NotificationcvaProcessStartcurrentA cvaProcessStart notification signifies that a process has just started. This notification is intended to work in conjunction with the caProcessStop notificat…
1.3.6.1.4.1.9.9.190.2.0.5NotificationcvaProcessStopcurrentA cvaProcessStop notification signifies that a process has just stopped. This notification is intended to work in conjunction with the cvaProcessStart notifica…
1.3.6.1.4.1.9.9.190.3NodeciscoVoiceAppsMIBConformance
1.3.6.1.4.1.9.9.190.3.1NodeciscoVoiceAppsMIBCompliances
1.3.6.1.4.1.9.9.190.3.1.1ComplianceciscoVoiceAppsMIBCompliancecurrentThe compliance statement for entities which implement the CISCO APPLICATION MIB.
1.3.6.1.4.1.9.9.190.3.2NodeciscoVoiceAppsMIBGroups
1.3.6.1.4.1.9.9.190.3.2.1GroupcvaModuleInfoGroupcurrentA collection of objects which provide info about the application. It comprises of all the modules and servers associated with the application.
1.3.6.1.4.1.9.9.190.3.2.2GroupcvaNotificationInfoGroupcurrentA collection of notification objects which provide info about the application notification.
1.3.6.1.4.1.9.9.190.3.2.3GroupcvaNotificationGroupcurrentA collection of notifications.