MIB Viewer

CISCO-WAN-MODULE-MIB

34 objects
The MIB to configure Connection Specific parameters and statistics related information in a Service Module. The Service Module(SM) is defined as any Module which provides services such as ATM, Frame Relay or Voice in a Wide Area Network(WAN) switch.
Imported Objects
CISCO-SMIciscoMgmt
SNMPv2-CONFMODULE-COMPLIANCE OBJECT-GROUP
SNMPv2-SMIMODULE-IDENTITY OBJECT-TYPE Unsigned32
SNMPv2-TCDisplayString TEXTUAL-CONVENTION
OIDNameAccessStatusDescription
1.3.6.1.4.1.9.9.145IdentityciscoWanModuleMIBThe MIB to configure Connection Specific parameters and statistics related information in a Service Module. The Service Module(SM) is defined as any Module whi…
1.3.6.1.4.1.9.9.145.1NodecwmMIBObjects
1.3.6.1.4.1.9.9.145.1.1NodecwmConfig
1.3.6.1.4.1.9.9.145.1.1.1TablecwmConfigTablenot-accessiblecurrentThis table contains objects required for configuring module specific parameters. These parameters may be related to the hardware specific parameters which can …
1.3.6.1.4.1.9.9.145.1.1.1.1RowcwmConfigEntrynot-accessiblecurrentEntry containing information for each module.
1.3.6.1.4.1.9.9.145.1.1.1.1.1ColumncwmIndexnot-accessiblecurrentThis object's value generally corresponds to the slot number where the module resides. However, system wide uniqueness is the only true requirement.
1.3.6.1.4.1.9.9.145.1.1.1.1.2ColumncwmIngressSCTFileIdread-writecurrentThe file ID of the Service Class Template(SCT) file. The SCT holds the connection specific parameters for this module in the ingress direction(From Network to …
1.3.6.1.4.1.9.9.145.1.1.1.1.3ColumncwmIngressSCTFileNameread-writecurrentThis variable contains the SCT filename. Write access is not required. The filename has cwmIngressSCTFileId value as the suffix. For example, the value SCT.ING…
1.3.6.1.4.1.9.9.145.1.1.1.1.4ColumncwmAutoLineDiagEnableread-writecurrentThis object enables/disables automatic diagnostic feature of physical lines on module. In case of a line alarm, enabling this feature temporarily suspends traf…
1.3.6.1.4.1.9.9.145.1.1.1.1.5ColumncwmSCTFileVerCfgread-writecurrentThe Configured version of the Service Class Template(SCT) file. This version applies to both the card SCT and the port SCT files in a service module. The port …
1.3.6.1.4.1.9.9.145.1.1.1.1.6ColumncwmSCTFileVerOprread-onlycurrentThe operational version of the Service Class Template(SCT) file. This is sct version currently in use. The operational version could be different from the conf…
1.3.6.1.4.1.9.9.145.1.1.1.1.7ColumncwmUploadCounterread-onlycurrentThis counter is used by the management station to determine if any changes(other than ATM/FR connections) have been done on configuration of a card. The use of…
1.3.6.1.4.1.9.9.145.1.2NodecwmStatsConfig
1.3.6.1.4.1.9.9.145.1.2.1TablecwmStatConfigTablenot-accessiblecurrentThis table has objects required for configuring module statistic collection related parameters. The statistics related to interfaces and ATM Connections are st…
1.3.6.1.4.1.9.9.145.1.2.1.1RowcwmStatConfigEntrynot-accessiblecurrentEntry containing statistics configuration information for the module.
1.3.6.1.4.1.9.9.145.1.2.1.1.1ColumncwmStatBucketIntervalread-writecurrentThis object contains the bucket interval in minutes used in collecting statistics. This specifies the interval over which the module accumulates a sample. This…
1.3.6.1.4.1.9.9.145.1.2.1.1.2ColumncwmStatCollectionIntervalread-writecurrentThe collection interval of statistics. Within a sampling interval, as defined by cwmStatBucketInterval, statistics counters are updated every collection interv…
1.3.6.1.4.1.9.9.145.1.2.1.1.3ColumncwmStatCollectionStatusread-writecurrentEnables or disables statistics collection on the module.
1.3.6.1.4.1.9.9.145.1.2.1.1.4ColumncwmStatCurrentLevelread-onlycurrentThe current statistics level of the module. A change in the card statistic level can take place only after a module reset. This object shows the current module…
1.3.6.1.4.1.9.9.145.1.2.1.1.5ColumncwmStatLevelConfiguredread-writecurrentThis object is used to configure the statistics level for the module. The statistics level value set in this object will take effect only on reset of the modul…
1.3.6.1.4.1.9.9.145.1.2.1.1.6ColumncwmStatMaximumConnectionsread-onlycurrentThe maximum number of connections for which the statistics are being collected.
1.3.6.1.4.1.9.9.145.2NodeciscoWanModuleMIBNotificationPrefix
1.3.6.1.4.1.9.9.145.2.0NodeciscoWanModuleMIBNotifications
1.3.6.1.4.1.9.9.145.3NodeciscoWanModuleMIBConformance
1.3.6.1.4.1.9.9.145.3.1NodeciscoWanModuleMIBCompliances
1.3.6.1.4.1.9.9.145.3.1.1ComplianceciscoWanModuleMIBComplianceread-onlydeprecatedThe Compliance statement for cwmConfigGroup group.
1.3.6.1.4.1.9.9.145.3.1.2ComplianceciscoWanModuleMIBComplianceRev1read-onlydeprecatedThe Compliance statement for cwmConfigGroup group, with addition of SCT file versioning
1.3.6.1.4.1.9.9.145.3.1.3ComplianceciscoWanModuleMIBComplianceRev2read-onlycurrentThe Compliance statement for cwmConfigGroup group, with addition of SCT file versioning
1.3.6.1.4.1.9.9.145.3.2NodeciscoWanModuleMIBGroups
1.3.6.1.4.1.9.9.145.3.2.1GroupcwmConfigGroupcurrentGroup containing Module Specific Parameters.
1.3.6.1.4.1.9.9.145.3.2.2GroupcwmStatConfigGroupcurrentGroup containing statistics configuration.
1.3.6.1.4.1.9.9.145.3.2.3GroupcwmConfigGroup2currentGroup containing additional Module Specific Parameters.
1.3.6.1.4.1.9.9.145.3.2.4GroupcwmUploadGroupcurrentGroup containing objects related to configuration changes in a card.
Type Definitions
NameSyntaxStatusDescription
StatisticsLevelINTEGER{ notApplicable(0), levelOne(1), levelTwo(2), levelThree(3) }currentUsed to configure level statistics on service module. Statistic level on a module dictates the type and amount of statistics that is collected. There is a predefined set of statistics associated with each level and are …