MIB Viewer

CISCO-WAN-VISM-TONE-PLAN-MIB

63 objects
The MIB module is defined to configure the programmable Tone Plan feature on VISM.
Imported Objects
CISCOWAN-SMIciscoWan
SNMPv2-CONFMODULE-COMPLIANCE OBJECT-GROUP
SNMPv2-SMIInteger32 MODULE-IDENTITY OBJECT-TYPE
SNMPv2-TCDisplayString RowStatus
OIDNameAccessStatusDescription
1.3.6.1.4.1.351.150.24IdentityvismTonePlanGrpMIBThe MIB module is defined to configure the programmable Tone Plan feature on VISM.
1.3.6.1.4.1.351.150.24.1NodevismTonePlanGrpMIBObjects
1.3.6.1.4.1.351.150.24.1.1NodevismTonePlan
1.3.6.1.4.1.351.150.24.1.1.1NodevismTonePlanControlGrp
1.3.6.1.4.1.351.150.24.1.1.1.1ScalartonePlanCurrentSizeread-onlycurrentThis object specifies the number of entries in vismTonePlanTable.
1.3.6.1.4.1.351.150.24.1.1.2NodevismTonePlanTableGrp
1.3.6.1.4.1.351.150.24.1.1.2.1TablevismTonePlanTablenot-accessiblecurrentThis table contains configuration information about different Tone Plans. The first 32 entries of the table are 'provisionable' followed by an implementation s…
1.3.6.1.4.1.351.150.24.1.1.2.1.1RowvismTonePlanEntrynot-accessiblecurrentAn entry in the vismTonePlanTable. Each entry consists of configuration information for a specific Tone Plan. The vismTonePlanTable is of fixed size with a pre…
1.3.6.1.4.1.351.150.24.1.1.2.1.1.1ColumntonePlanIndexnot-accessiblecurrentServes as index to this table. However, the maximum entry allowed is specify in tonePlanCurrentSize.
1.3.6.1.4.1.351.150.24.1.1.2.1.1.2ColumntonePlanEntryStatusread-writecurrentThis attribute specifies the status of this entry as to whether this entry (row) contains usable Tone Plan configuration information (object is set to 'configu…
1.3.6.1.4.1.351.150.24.1.1.2.1.1.3ColumntonePlanProvisionFlagread-onlycurrentThis attribute specifies whether this entry contains predefined Tone Plan configuration information from internal firmware code (object is set to 'builtIn') or…
1.3.6.1.4.1.351.150.24.1.1.2.1.1.4ColumntonePlanRegionNameread-writecurrentThe region (or country) for which this tone plan is defined. Any other entry in this table may have an identical name, but the combination of tonePlanRegionNam…
1.3.6.1.4.1.351.150.24.1.1.2.1.1.5ColumntonePlanVersionNumberread-writecurrentThis attribute specifies this entry's version number for a tone plan for a region. Multiple tone plans may be defined for each region, but each of these tone p…
1.3.6.1.4.1.351.150.24.1.1.2.1.1.6ColumntonePlanFileNameread-writecurrentThis is the name of a valid file stored on the TFTP server which contains the tone definitions. A missing or invalid file name will cause a failure in the conf…
1.3.6.1.4.1.351.150.24.1.1.3NodevismConfigToneDetectGrp
1.3.6.1.4.1.351.150.24.1.1.3.1TablevismConfigToneDetectTablenot-accessiblecurrentThis table contains the list of user configurable dual frequency tones that can be detected on VISM. The call agent can request the VISM to detect any of the t…
1.3.6.1.4.1.351.150.24.1.1.3.1.1RowvismConfigToneDetectEntrynot-accessiblecurrentThis is the primary entry in the vismConfigToneDetectTable. Each entry references a User configurable dual frequency tones that can be detected on VISM.
1.3.6.1.4.1.351.150.24.1.1.3.1.1.1ColumnvismConfigToneDetectNumread-onlycurrentThis is the index of this table. Currently only tones 1 to 10 are used and call agent can request up to ten tones to be detected on different endpoints at any …
1.3.6.1.4.1.351.150.24.1.1.3.1.1.2ColumnvismEventCoderead-createcurrentThis is the secondary index of this table. Call agent can request supervision tone detection indexed by this field. The values of event code are mapped from th…
1.3.6.1.4.1.351.150.24.1.1.3.1.1.3ColumnvismConfigToneDetectRowStatusread-createcurrentControls the creation and deletion of a Config Tone. An entry may be created using the 'createAndGo' option. When the row is successfully created, the vismConf…
1.3.6.1.4.1.351.150.24.1.1.3.1.1.4ColumnvismFreqMaxDeviationread-createcurrentSpecifies the maximum frequency deviation to be used by VISM when detecting a specific dual frequency tone. Please refer the VISM configuration guide for stand…
1.3.6.1.4.1.351.150.24.1.1.3.1.1.5ColumnvismFreqMaxPowerread-createcurrentSpecifies the maximum frequency power to be used by VISM when detecting a specific dual frequency tone. Please refer the VISM configuration guide for standard …
1.3.6.1.4.1.351.150.24.1.1.3.1.1.6ColumnvismFreqMinPowerread-createcurrentSpecifies the minimum frequency power to be used by VISM when detecting a specific dual frequency tone. Please refer the VISM configuration guide for standard …
1.3.6.1.4.1.351.150.24.1.1.3.1.1.7ColumnvismFreqPowerTwistread-createcurrentSpecifies the maximum frequency power twist permitted between the two frequencies used by VISM when detecting a dual frequency tone. Please refer the VISM conf…
1.3.6.1.4.1.351.150.24.1.1.3.1.1.8ColumnvismFreqMaxDelayread-createcurrentSpecifies the maximum frequency delay to be used by VISM when detecting a dual frequency tone. Please refer the VISM configuration guide for standard values to…
1.3.6.1.4.1.351.150.24.1.1.3.1.1.9ColumnvismMinOnCadenceread-createcurrentSpecifies the minimum tone cycle ON time that is necessary for the VISM to detect the dual frequency tone. The vismMinOnCadence has to be less than vismFreqOnC…
1.3.6.1.4.1.351.150.24.1.1.3.1.1.10ColumnvismMaxOffCadenceread-createcurrentSpecifies the maximum tone cycle OFF time that is necessary for the VISM to detect the dual frequency tone. The vismMaxOffCadence should be greater than vismFr…
1.3.6.1.4.1.351.150.24.1.1.3.1.1.11ColumnvismFreqNumOfCadenceMatchread-createcurrentSpecifies the number of pairs of the dual frequency that needs to be detected. Currently ten pairs of frequency can be detected by the DSP.
1.3.6.1.4.1.351.150.24.1.1.3.1.1.12ColumnvismFrequency1read-createcurrentSpecifies the 1st frequency component of the dual frequency to be detected by the VISM.
1.3.6.1.4.1.351.150.24.1.1.3.1.1.13ColumnvismFrequency2read-createcurrentSpecifies the 2nd frequency component of the dual frequency to be detected by the DSP. A value of 0 means this is a single frequency. The range of 1 to 279 is …
1.3.6.1.4.1.351.150.24.1.1.3.1.1.14ColumnvismFreqOnCadenceread-createcurrentThe On time in each cycle of the dual frequency to be detected by the DSP. The vismFreqOnCadence has to be less than vismMinOnCadence value. It is measured in …
1.3.6.1.4.1.351.150.24.1.1.3.1.1.15ColumnvismFreqOffCadenceread-createcurrentThe Off time in each cycle of the dual frequency to be detected by the DSP. The vismFreqOffCadence should be lesser than the vismMaxOffCadence value. It is mea…
1.3.6.1.4.1.351.150.24.1.1.4NodevismSequentialToneDetectGrp
1.3.6.1.4.1.351.150.24.1.1.4.1ScalarseqToneNumOfFrequenciesread-writecurrentThe number of single frequencies which have to be detected by the sequential tone detector command on VISM. The frequencies should specified below (seqToneFreq…
1.3.6.1.4.1.351.150.24.1.1.4.2ScalarseqToneEventIDread-writecurrentThe eventID corresponding to the sequential frequency. Currently only supports Event 74 (SIT tone)
1.3.6.1.4.1.351.150.24.1.1.4.3ScalarseqToneDurationOfEachToneread-writecurrentNominal tone duration of each single tone in counts of 10ms used with sequential tone detector on VISM DSP.
1.3.6.1.4.1.351.150.24.1.1.4.4ScalarseqToneGapBetweenEachToneread-writecurrentNominal silence gap duration between each tone in 10ms used with sequential tone detector on VISM DSP.
1.3.6.1.4.1.351.150.24.1.1.4.5ScalarseqToneDurationDeviationread-writecurrentTone duration deviation allowed in 10ms used with sequential tone detector on VISM DSP.
1.3.6.1.4.1.351.150.24.1.1.4.6ScalarseqToneMaximumGapDurationread-writecurrentMaximum tone duration allowed in 10ms used with sequential tone detector on VISM DSP.
1.3.6.1.4.1.351.150.24.1.1.4.7ScalarseqToneGapDurationDeviationread-writecurrentTone duration deviation allowed in 10ms used with sequential tone detector on VISM DSP.
1.3.6.1.4.1.351.150.24.1.1.4.8ScalarseqToneFreqDeviationread-writecurrentFrequency deviation allowed (1 - 1000 Hz) used with sequential tone detector on VISM DSP.
1.3.6.1.4.1.351.150.24.1.1.4.9ScalarseqTonePowerLevelCeilingread-writecurrentMaximum ceiling power level of the sequential frequency tone (absolute value in dBm) used with sequential tone detector on VISM DSP. Range from 0 to 40 (0 to -…
1.3.6.1.4.1.351.150.24.1.1.4.10ScalarseqTonePowerLevelFloorread-writecurrentLowest (floor) power level of the sequential frequency tone (absolute value in dBm) used with sequential tone detector on VISM DSP. Range from 0 to 40 (0 to -4…
1.3.6.1.4.1.351.150.24.1.1.4.11ScalarseqToneFrequency1read-writecurrent1st frequency in the SequentialTone to detect (280 - 3800), used with sequential tone detector on VISM DSP.
1.3.6.1.4.1.351.150.24.1.1.4.12ScalarseqToneFrequency2read-writecurrent2nd frequency in the SequentialTone to detect (280 - 3800), used with sequential tone detector on VISM DSP.
1.3.6.1.4.1.351.150.24.1.1.4.13ScalarseqToneFrequency3read-writecurrent3rd frequency in the SequentialTone to detect (280 - 3800), used with sequential tone detector on VISM DSP.
1.3.6.1.4.1.351.150.24.1.1.4.14ScalarseqToneFrequency4read-writecurrent4th frequency in the SequentialTone to detect (280 - 3800), used with sequential tone detector on VISM DSP.
1.3.6.1.4.1.351.150.24.1.1.4.15ScalarseqToneFrequency5read-writecurrent5th frequency in the SequentialTone to detect (280 - 3800), used with sequential tone detector on VISM DSP.
1.3.6.1.4.1.351.150.24.1.1.4.16ScalarseqToneFrequency6read-writecurrent6th frequency in the SequentialTone to detect (280 - 3800), used with sequential tone detector on VISM DSP.
1.3.6.1.4.1.351.150.24.1.1.4.17ScalarseqToneFrequency7read-writecurrent7th frequency in the SequentialTone to detect (280 - 3800), used with sequential tone detector on VISM DSP.
1.3.6.1.4.1.351.150.24.1.1.4.18ScalarseqToneFrequency8read-writecurrent8th frequency in the SequentialTone to detect (280 - 3800), used with sequential tone detector on VISM DSP.
1.3.6.1.4.1.351.150.24.1.1.4.19ScalarseqToneFrequency9read-writecurrent9th frequency in the SequentialTone to detect (280 - 3800), used with sequential tone detector on VISM DSP.
1.3.6.1.4.1.351.150.24.1.1.4.20ScalarseqToneFrequency10read-writecurrent10th frequency in the SequentialTone to detect (280 - 3800), used with sequential tone detector on VISM DSP.
1.3.6.1.4.1.351.150.24.2NodevismToneNotificationPrefix
1.3.6.1.4.1.351.150.24.2.0NodevismToneNotifications
1.3.6.1.4.1.351.150.24.3NodevismTonePlanMIBConformance
1.3.6.1.4.1.351.150.24.3.1NodevismTonePlanMIBCompliances
1.3.6.1.4.1.351.150.24.3.1.1CompliancevismTonePlanMIBCompliancecurrentThe complaince statement for VISM Tone Plan group which implements vismTonePlanGrp MIB.
1.3.6.1.4.1.351.150.24.3.2NodevismTonePlanMIBGroups
1.3.6.1.4.1.351.150.24.3.2.1GroupvismTonePlanControlGroupcurrentThis group contains objects related to control of VISM Tone Plan Table.
1.3.6.1.4.1.351.150.24.3.2.2GroupvismTonePlanTableGroupcurrentThis group contains objects related to configuration of VISM Tone Plan.
1.3.6.1.4.1.351.150.24.3.2.3GroupvismConfigToneDetectTableGroupcurrentThis group contains objects related to configuration of VISM dual frequency detect tones.
1.3.6.1.4.1.351.150.24.3.2.4GroupvismSequentialToneDetectGroupcurrentThis group contains objects related to configuration of VISM sequential single frequency tone detection.