MIB Viewer

CME-MIB

2352 objects
No module-level DESCRIPTION found.
Imported Objects
OIDNameAccessStatusDescription
1.3.6.1.4.1.2Nodeibm
1.3.6.1.4.1.2.3NodeibmAgents
1.3.6.1.4.1.2.3.51NodenetfinitySupportProcessorAgent
1.3.6.1.4.1.2.3.51.2NodebladeCenterSnmpMIB
1.3.6.1.4.1.2.3.51.2.2Nodemonitors
1.3.6.1.4.1.2.3.51.2.2.1Nodetemperature
1.3.6.1.4.1.2.3.51.2.2.1.1NodeinternalTemp
1.3.6.1.4.1.2.3.51.2.2.1.1.2ScalarcmmTempread-onlydeprecatedThis field is deprecated. The return value of this field is the same as rearLEDCardTemp. Chassis management module temperature in degrees centigrade(C). An oct…
1.3.6.1.4.1.2.3.51.2.2.1.5NodeambientTemp
1.3.6.1.4.1.2.3.51.2.2.1.5.1ScalarrearLEDCardTempAvgread-onlymandatoryThe average rear LED card temperature in degrees centigrade(C). This is surrounding temperature where the system is installed. An octet string expressed as 'sd…
1.3.6.1.4.1.2.3.51.2.2.1.5.2ScalarrearLEDCardTempMinread-onlymandatoryThe minimum rear LED card temperature in degrees centigrade(C). This is surrounding temperature where the system is installed. An octet string expressed as 'sd…
1.3.6.1.4.1.2.3.51.2.2.1.5.3ScalarrearLEDCardTempMaxread-onlymandatoryThe maximum rear LED card temperature in degrees centigrade(C). This is surrounding temperature where the system is installed. An octet string expressed as 'sd…
1.3.6.1.4.1.2.3.51.2.2.1.9NodemonitorTemp
1.3.6.1.4.1.2.3.51.2.2.1.9.3ScalarhotAirRecircMonitoringread-writemandatoryIf this is enabled, the management module will monitor for Hot Air Recirculation by detecting non-uniform air temperature(s) that may be entering the front of …
1.3.6.1.4.1.2.3.51.2.2.1.9.5ScalarhotAirRecircTempDeltaThreshread-writemandatoryThis object is used to read or change the temperature delta threshold for Hot Air Recirculation detection. Values are enforced to be in the inclusive range bet…
1.3.6.1.4.1.2.3.51.2.2.1.9.7TablehotAirRecircStatusTablenot-accessiblemandatoryTable of hot air recirculation status information.
1.3.6.1.4.1.2.3.51.2.2.1.9.7.1RowhotAirRecircStatusEntrynot-accessiblemandatoryHot air recirculation status entry
1.3.6.1.4.1.2.3.51.2.2.1.9.7.1.2ColumnhotAirRecircStatusTopologyPathread-onlymandatoryThe unique identifier for a component in this table. The chassis and each installed component is represented by a hardware topology tree, where each node in th…
1.3.6.1.4.1.2.3.51.2.2.1.9.7.1.3ColumnhotAirRecircStatusIndexread-onlymandatoryEach component may have one or more sensor associated with it, this index object identifies the particular instance.
1.3.6.1.4.1.2.3.51.2.2.1.9.7.1.4ColumnhotAirRecircStatusNameread-onlymandatoryThe name of the component as a null terminated string
1.3.6.1.4.1.2.3.51.2.2.1.9.7.1.5ColumnhotAirRecircStatusSensorLabelread-onlymandatoryThe text label of the sensor as a null terminated string
1.3.6.1.4.1.2.3.51.2.2.1.9.7.1.6ColumnhotAirRecircStatusSensorReadingread-onlymandatoryAmbient temperature reading for this component in degrees centigrade(C). The string is formatted as 'dd.dd Centigrade'.
1.3.6.1.4.1.2.3.51.2.2.1.9.7.1.7ColumnhotAirRecircStatusExceededread-onlymandatoryIndicates whether this component has exceeded the threshold of the acceptable temperature being monitored for hot air recirculation.
1.3.6.1.4.1.2.3.51.2.2.3NodechassisFans
1.3.6.1.4.1.2.3.51.2.2.3.50TablechassisFansTablenot-accessiblemandatoryTable of chassis Fan information.
1.3.6.1.4.1.2.3.51.2.2.3.50.1RowchassisFansEntrynot-accessiblemandatoryChassis Fan information entry
1.3.6.1.4.1.2.3.51.2.2.3.50.1.1ColumnchassisFanIndexread-onlymandatoryChassis Fans table index.
1.3.6.1.4.1.2.3.51.2.2.3.50.1.2ColumnchassisFanIdread-onlymandatoryThe numeric chassis fan ID.
1.3.6.1.4.1.2.3.51.2.2.3.50.1.3ColumnchassisFanSpeedread-onlymandatoryChassis fan speed expressed in percent(%) of maximum RPM. An octet string expressed as 'ddd% of maximum' where: d is a decimal digit or blank space for a leadi…
1.3.6.1.4.1.2.3.51.2.2.3.50.1.4ColumnchassisFanStateread-onlymandatoryThe health state for the chassis fan. Note that the other UIs may use slightly different terminology for the three health state values, as such: WEB - Normal, …
1.3.6.1.4.1.2.3.51.2.2.3.50.1.5ColumnchassisFanSpeedRPMread-onlymandatoryChassis fan speed expressed in RPM. If the chassis fan is determined not to be running or the chassis fan speed cannot be determined, the string will indicate …
1.3.6.1.4.1.2.3.51.2.2.3.50.1.6ColumnchassisFanControllerStateread-onlymandatoryThe controller health state for the chassis fan.
1.3.6.1.4.1.2.3.51.2.2.3.50.1.7ColumnchassisFanCoolingZoneread-onlymandatoryThe cooling zone for the chassis fan.
1.3.6.1.4.1.2.3.51.2.2.3.51TablechassisCoolingZoneTablenot-accessiblemandatoryTable of chassis cooling zone information.
1.3.6.1.4.1.2.3.51.2.2.3.51.1RowchassisCoolingZoneEntrynot-accessiblemandatoryChassis cooling zone information entry
1.3.6.1.4.1.2.3.51.2.2.3.51.1.1ColumnchassisCoolingIndexread-onlymandatoryChassis Cooling Zones table index.
1.3.6.1.4.1.2.3.51.2.2.3.51.1.2ColumnchassisCoolingZoneread-onlymandatoryThe cooling zone for the chassis component.
1.3.6.1.4.1.2.3.51.2.2.3.51.1.3ColumnchassisCoolingZoneStatusread-onlymandatoryThe health state of the chassis cooling zone. Note: This is the health of the cooling zone, not the health status of the component in chassisCoolingZoneCompone…
1.3.6.1.4.1.2.3.51.2.2.3.51.1.4ColumnchassisCoolingZoneComponentread-onlymandatoryA component within a cooling zone.
1.3.6.1.4.1.2.3.51.2.2.4NodepowerModuleHealth
1.3.6.1.4.1.2.3.51.2.2.4.1TablepowerModuleHealthTablenot-accessiblemandatoryTable of power module health information. Contains the power health information for each power module.
1.3.6.1.4.1.2.3.51.2.2.4.1.1RowpowerModuleHealthEntrynot-accessiblemandatoryPower Module health entry
1.3.6.1.4.1.2.3.51.2.2.4.1.1.1ColumnpowerModuleIndexread-onlymandatoryPower module index.
1.3.6.1.4.1.2.3.51.2.2.4.1.1.2ColumnpowerModuleExistsread-onlymandatoryIndicates whether the power module specified exists or not.
1.3.6.1.4.1.2.3.51.2.2.4.1.1.3ColumnpowerModuleStateread-onlymandatoryThe health state for the power module. Note that the other UIs may use slightly different terminology for the three health state values, as such: WEB - Normal,…
1.3.6.1.4.1.2.3.51.2.2.4.1.1.4ColumnpowerModuleDetailsread-onlymandatoryThe details for this power module.
1.3.6.1.4.1.2.3.51.2.2.4.1.1.9ColumnpowerModuleDescriptionread-onlymandatoryThe description for this power module.
1.3.6.1.4.1.2.3.51.2.2.5NodespStatus
1.3.6.1.4.1.2.3.51.2.2.5.2NodemmBistAndChassisStatus
1.3.6.1.4.1.2.3.51.2.2.5.2.5ScalarbistRtcread-onlymandatoryMM BIST Real Time Clock test result.
1.3.6.1.4.1.2.3.51.2.2.5.2.7ScalarbistLocalI2CBusread-onlymandatoryMM BIST Local I2C bus test result.
1.3.6.1.4.1.2.3.51.2.2.5.2.8ScalarbistPrimaryMainAppFlashImageread-onlymandatoryMM BIST Primary Main Application Firmware test result.
1.3.6.1.4.1.2.3.51.2.2.5.2.9ScalarbistSecondaryMainAppFlashImageread-onlymandatoryMM BIST Secondary Main Application test result.
1.3.6.1.4.1.2.3.51.2.2.5.2.10ScalarbistBootRomFlashImageread-onlymandatoryMM BIST Boot Firmware test result.
1.3.6.1.4.1.2.3.51.2.2.5.2.11ScalarbistEthernetPort1read-onlymandatoryMM BIST external eth0 ethernet port test result.
1.3.6.1.4.1.2.3.51.2.2.5.2.14ScalarbistExternalI2CDevicesread-onlymandatoryMM BIST external I2C devices test result.
1.3.6.1.4.1.2.3.51.2.2.5.2.19ScalarbistInternalEthernetSwitchread-onlymandatoryMM BIST internal external switch test result.
1.3.6.1.4.1.2.3.51.2.2.5.2.25ScalarbistPrimaryKernelread-onlymandatoryMM BIST primary kernel test result.
1.3.6.1.4.1.2.3.51.2.2.5.2.26ScalarbistSecondaryKernelread-onlymandatoryMM BIST secondary kernel test result.
1.3.6.1.4.1.2.3.51.2.2.5.2.29ScalarbistPhysicalNetworkLinkread-onlymandatoryMM BIST Physical Network Link test result.
1.3.6.1.4.1.2.3.51.2.2.5.2.30ScalarbistLogicalNetworkLinkread-onlymandatoryMM BIST Logical Network Link test result.
1.3.6.1.4.1.2.3.51.2.2.5.2.33ScalarbistBladesInstalledread-onlymandatoryThe blades that are installed on the chassis. The blades are listed as a bitmap. The bitmap is a string containing a list of 1's and 0's that is as long as the…
1.3.6.1.4.1.2.3.51.2.2.5.2.49ScalarbistBladesCommunicatingread-onlymandatoryThe blades that are communicating on the chassis. The blades are listed as a bitmap. The bitmap is a string containing a list of 1's and 0's that is as long as…
1.3.6.1.4.1.2.3.51.2.2.5.2.65ScalarbistChassisFansInstalledread-onlymandatoryThe chassis fans that are installed on the chassis. They are listed as a bitmap. The bitmap is a string containing a list of 1's and 0's that is as long as the…
1.3.6.1.4.1.2.3.51.2.2.5.2.73ScalarbistChassisFansFunctionalread-onlymandatoryThe chassis fans installed on the chassis that are functional. They are listed as a bitmap. The bitmap is a string containing a list of 1's and 0's that is as …
1.3.6.1.4.1.2.3.51.2.2.5.2.74ScalarbistRearLEDCardInstalledread-onlymandatoryIndicates whether a rear LED card is installed
1.3.6.1.4.1.2.3.51.2.2.5.2.75ScalarbistRearLEDCardCommunicatingread-onlymandatoryIndicates whether a rear LED card is communicating
1.3.6.1.4.1.2.3.51.2.2.5.2.76ScalarbistOtherMMInstalledread-onlymandatoryIndicates whether a redundant MM is installed.
1.3.6.1.4.1.2.3.51.2.2.5.2.77ScalarbistOtherMMCommunicatingread-onlymandatoryIndicates whether a redundant MM is communicating.
1.3.6.1.4.1.2.3.51.2.2.5.2.81ScalarbistPowerModulesInstalledread-onlymandatoryThe power modules that are installed on the chassis. The power modules are listed as a bitmap. The bitmap is a string containing a list of 1's and 0's that is …
1.3.6.1.4.1.2.3.51.2.2.5.2.89ScalarbistPowerModulesFunctionalread-onlymandatoryThe power modules that are functional on the chassis. The power modules are listed as a bitmap. The bitmap is a string containing a list of 1's and 0's that is…
1.3.6.1.4.1.2.3.51.2.2.5.2.97ScalarbistSwitchModulesInstalledread-onlymandatoryThe switch modules that are installed on the chassis. The switch modules are listed as a bitmap. The bitmap is a string containing a list of 1's and 0's that i…
1.3.6.1.4.1.2.3.51.2.2.5.2.113ScalarbistSwitchModulesCommunicatingread-onlymandatoryThe switch modules that are communicating on the chassis. The switch modules are listed as a bitmap. The bitmap is a string containing a list of 1's and 0's th…
1.3.6.1.4.1.2.3.51.2.2.5.2.120ScalarbistChassisFansMUXAInstalledread-onlymandatoryIndicates whether chassis fan MUX A is installed
1.3.6.1.4.1.2.3.51.2.2.5.2.121ScalarbistChassisFansMUXAFunctionalread-onlymandatoryIndicates whether chassis fan MUX A is functional
1.3.6.1.4.1.2.3.51.2.2.5.2.122ScalarbistChassisFansMUXBInstalledread-onlymandatoryIndicates whether chassis fan MUX B is installed
1.3.6.1.4.1.2.3.51.2.2.5.2.123ScalarbistChassisFansMUXBFunctionalread-onlymandatoryIndicates whether chassis fan MUX B is functional
1.3.6.1.4.1.2.3.51.2.2.5.2.200ScalarbistLastUpdateread-onlymandatoryIt is the time when the primary MM updated the last BIST results.
1.3.6.1.4.1.2.3.51.2.2.5.3NodermmBistAndChassisStatus
1.3.6.1.4.1.2.3.51.2.2.5.3.5ScalarrbistRtcread-onlymandatoryStandby MM BIST Real Time Clock test result. The time of the last update can be obtained by querying rbistUpdateTime object.
1.3.6.1.4.1.2.3.51.2.2.5.3.7ScalarrbistLocalI2CBusread-onlymandatoryStandby MM BIST Local I2C bus test result. The time of the last update can be obtained by querying rbistUpdateTime object.
1.3.6.1.4.1.2.3.51.2.2.5.3.11ScalarrbistEthernetPort1read-onlymandatoryStandby MM BIST external ethernet port test result. The time of the last update can be obtained by querying rbistUpdateTime object.
1.3.6.1.4.1.2.3.51.2.2.5.3.14ScalarrbistExternalI2CDevicesread-onlymandatoryStandby MM BIST external I2C devices test result collected when the standby MM was primary. The time of the last update can be obtained by querying rbistUpdate…
1.3.6.1.4.1.2.3.51.2.2.5.3.19ScalarrbistInternalEthernetSwitchread-onlymandatoryStandby MM BIST internal external switch test result. The time of the last update can be obtained by querying rbistUpdateTime object.
1.3.6.1.4.1.2.3.51.2.2.5.3.29ScalarrbistPhysicalNetworkLinkread-onlymandatoryStandby MM BIST Physical Network Link test result collected when the standby MM was primary. The time of the last update can be obtained by querying rbistUpdat…
1.3.6.1.4.1.2.3.51.2.2.5.3.30ScalarrbistLogicalNetworkLinkread-onlymandatoryStandby MM BIST Logical Network Link test result collected when the standby MM was primary. The time of the last update can be obtained by querying rbistUpdate…
1.3.6.1.4.1.2.3.51.2.2.5.3.33ScalarrbistBladesInstalledread-onlymandatoryThe blades that were installed on the chassis when the standby MM was once primary. The time of the last update can be obtained by querying rbistUpdateTimePrim…
1.3.6.1.4.1.2.3.51.2.2.5.3.49ScalarrbistBladesCommunicatingread-onlymandatoryThe blades that were communicating on the chassis when the standby MM was once primary. The time of the last update can be obtained by querying rbistUpdateTime…
1.3.6.1.4.1.2.3.51.2.2.5.3.65ScalarrbistChassisFansInstalledread-onlymandatoryThe chassis fans that were installed on the chassis when the standby MM was once primary. The time of the last update can be obtained by querying rbistUpdateTi…
1.3.6.1.4.1.2.3.51.2.2.5.3.73ScalarrbistChassisFansFunctionalread-onlymandatoryThe chassis fans installed on the chassis that were functional when the standby MM was once primary. The time of the last update can be obtained by querying rb…
1.3.6.1.4.1.2.3.51.2.2.5.3.74ScalarrbistRearLEDCardInstalledread-onlymandatoryIndicates whether a rear LED card is installed
1.3.6.1.4.1.2.3.51.2.2.5.3.75ScalarrbistRearLEDCardCommunicatingread-onlymandatoryIndicates whether a rear LED card is communicating
1.3.6.1.4.1.2.3.51.2.2.5.3.76ScalarrbistOtherMMInstalledread-onlymandatoryIndicates whether a standby MM was installed when the standby MM was once primary.The time of the last update can be obtained by querying rbistUpdateTimePrimar…
1.3.6.1.4.1.2.3.51.2.2.5.3.77ScalarrbistOtherMMCommunicatingread-onlymandatoryIndicates whether a standby MM was communicating when the standby MM was once primary. The time of the last update can be gotten from the object 'rbistUpdateTi…
1.3.6.1.4.1.2.3.51.2.2.5.3.81ScalarrbistPowerModulesInstalledread-onlymandatoryThe power modules that were installed on the chassis when the standby MM was once primary. The time of the last update can be obtained by querying rbistUpdateT…
1.3.6.1.4.1.2.3.51.2.2.5.3.89ScalarrbistPowerModulesFunctionalread-onlymandatoryThe power modules that were functional on the chassis when the standby MM was once primary. The time of the last update can be obtained by querying rbistUpdate…
1.3.6.1.4.1.2.3.51.2.2.5.3.97ScalarrbistSwitchModulesInstalledread-onlymandatoryThe switch modules that were installed on the chassis when the standby MM was once primary. The time of the last update can be obtained by querying rbistUpdate…
1.3.6.1.4.1.2.3.51.2.2.5.3.113ScalarrbistSwitchModulesCommunicatingread-onlymandatoryThe switch modules that are communicating on the chassis when the standby MM was once primary. The time of the last update can be obtained by querying rbistUpd…
1.3.6.1.4.1.2.3.51.2.2.5.3.120ScalarrbistChassisFansMUXAInstalledread-onlymandatoryIndicates whether chassis fan MUX A is installed
1.3.6.1.4.1.2.3.51.2.2.5.3.121ScalarrbistChassisFansMUXAFunctionalread-onlymandatoryIndicates whether chassis fan MUX A is functional
1.3.6.1.4.1.2.3.51.2.2.5.3.122ScalarrbistChassisFansMUXBInstalledread-onlymandatoryIndicates whether chassis fan MUX B is installed
1.3.6.1.4.1.2.3.51.2.2.5.3.123ScalarrbistChassisFansMUXBFunctionalread-onlymandatoryIndicates whether chassis fan MUX B is functional
1.3.6.1.4.1.2.3.51.2.2.5.3.200ScalarrbistUpdateTimeread-onlymandatoryIt is the time when the standby MM updated the last BIST results.
1.3.6.1.4.1.2.3.51.2.2.5.3.201ScalarrbistLastUpdatePrimaryread-onlymandatoryIt is the time when the standby MM updated the last BIST results when it was still primary.
1.3.6.1.4.1.2.3.51.2.2.6NodefanPack
1.3.6.1.4.1.2.3.51.2.2.6.1TablefanPackTablenot-accessiblemandatoryTable of fan pack information. Contains the information for each fan pack. NOTE: Fan packs are also referred to as Power Module Cooling Devices.
1.3.6.1.4.1.2.3.51.2.2.6.1.1RowfanPackEntrynot-accessiblemandatoryFan Pack entry
1.3.6.1.4.1.2.3.51.2.2.6.1.1.1ColumnfanPackIndexread-onlymandatoryFan Pack sequence index.
1.3.6.1.4.1.2.3.51.2.2.6.1.1.2ColumnfanPackExistsread-onlymandatoryIndicates whether the fan pack specified exists or not.
1.3.6.1.4.1.2.3.51.2.2.6.1.1.3ColumnfanPackStateread-onlymandatoryThe health state for the fan pack. Note that the other UIs may use slightly different terminology for the three health state values, as such: WEB - Normal, Att…
1.3.6.1.4.1.2.3.51.2.2.6.1.1.4ColumnfanPackFanCountread-onlymandatoryThe number of fans in the fan pack.
1.3.6.1.4.1.2.3.51.2.2.6.1.1.5ColumnfanPackAverageSpeedread-onlymandatoryThe average speed of all fans in the fan pack expressed in percent(%) of maximum RPM. If the fan pack is determined not to be running or the fan pack speed can…
1.3.6.1.4.1.2.3.51.2.2.6.1.1.6ColumnfanPackAverageSpeedRPMread-onlymandatoryThe average speed of all fans in the fan pack expressed in RPM. If the fan pack is determined not to be running or the fan pack speed cannot be determined, the…
1.3.6.1.4.1.2.3.51.2.2.6.1.1.7ColumnfanPackControllerStateread-onlymandatoryThe health state for the controller for the fan pack.
1.3.6.1.4.1.2.3.51.2.2.7NodesystemHealth
1.3.6.1.4.1.2.3.51.2.2.7.1ScalarsystemHealthStatread-onlymandatoryIndicates status of system health for the system in which the MM resides. Value of 'critical' indicates a severe error has occurred and the system may not be f…
1.3.6.1.4.1.2.3.51.2.2.7.2TablesystemHealthSummaryTablenot-accessiblemandatoryTable of System Health summary. Contains more detailed information about the reasons for the overall system health status.
1.3.6.1.4.1.2.3.51.2.2.7.2.1RowsystemHealthSummaryEntrynot-accessiblemandatorySystem Health Summary entry
1.3.6.1.4.1.2.3.51.2.2.7.2.1.1ColumnsystemHealthSummaryIndexread-onlymandatorySystem health summary index.
1.3.6.1.4.1.2.3.51.2.2.7.2.1.2ColumnsystemHealthSummarySeverityread-onlymandatorySystem health summary severity.
1.3.6.1.4.1.2.3.51.2.2.7.2.1.3ColumnsystemHealthSummaryDescriptionread-onlymandatorySystem health summary description.
1.3.6.1.4.1.2.3.51.2.2.7.2.1.4ColumnsystemHealthSummaryDateTimeread-onlymandatorySystem health summary date time.
1.3.6.1.4.1.2.3.51.2.2.7.2.1.11ColumnsystemHealthSummaryAuxDataread-onlymandatorySystem health summary auxilliary event data. If auxilliary event data is available, it is device-specific event data provided to the CMM by the device.
1.3.6.1.4.1.2.3.51.2.2.7.2.1.12ColumnsystemHealthSummaryEventIDread-onlymandatorySystem health summary event ID.
1.3.6.1.4.1.2.3.51.2.2.8Nodeleds
1.3.6.1.4.1.2.3.51.2.2.8.1NodefrontPanelLEDs
1.3.6.1.4.1.2.3.51.2.2.8.1.1ScalarfaultLEDread-onlymandatoryIndicates whether the front panel system error LED is on or off.
1.3.6.1.4.1.2.3.51.2.2.8.1.2ScalarcheckLogLEDread-writemandatoryIndicates whether the front panel system information LED is on or off. For Write access, the LED can be turned off only.
1.3.6.1.4.1.2.3.51.2.2.8.1.4ScalaridentifyLEDread-writemandatoryIndicates whether the front panel identity LED is on or off.
1.3.6.1.4.1.2.3.51.2.2.8.2NodebladeLEDs
1.3.6.1.4.1.2.3.51.2.2.8.2.1TablebladeLEDsTablenot-accessiblemandatoryTable of blade status information. NOTE: Querying objects in this table may take significantly longer than normal, so it is recommended that the query timeout …
1.3.6.1.4.1.2.3.51.2.2.8.2.1.1RowbladeLEDsEntrynot-accessiblemandatoryBlade system status entry
1.3.6.1.4.1.2.3.51.2.2.8.2.1.1.1ColumnledBladeIndexread-onlymandatoryBlade LED table index.
1.3.6.1.4.1.2.3.51.2.2.8.2.1.1.2ColumnledBladeIdread-onlymandatoryThe numeric blade ID.
1.3.6.1.4.1.2.3.51.2.2.8.2.1.1.3ColumnledBladeExistsread-onlymandatoryIndicates whether the blade specified exists or not.
1.3.6.1.4.1.2.3.51.2.2.8.2.1.1.4ColumnledBladePowerStateread-onlymandatoryIndicates the power state of the blade specified.
1.3.6.1.4.1.2.3.51.2.2.8.2.1.1.5ColumnledBladeHealthStateread-onlymandatoryThe system health state for the blade. Unknown: Blade is in an undefined state. Good: Blade is operating normally. Warning: One or more outstanding warnings ex…
1.3.6.1.4.1.2.3.51.2.2.8.2.1.1.6ColumnledBladeNameread-onlymandatoryThe name of the blade as a null terminated string.
1.3.6.1.4.1.2.3.51.2.2.8.2.1.1.7ColumnledBladeFaultread-onlymandatoryIndicates whether the blade fault LED is on or off.
1.3.6.1.4.1.2.3.51.2.2.8.2.1.1.8ColumnledBladeCheckLogread-writemandatoryIndicates whether the blade check log information LED is on or off. For Write access, the LED can be turned off only.
1.3.6.1.4.1.2.3.51.2.2.8.2.1.1.11ColumnledBladeIdentifyread-writemandatoryIndicates whether the blade identify LED is on, off, or blinking.
1.3.6.1.4.1.2.3.51.2.2.8.2.2TablebladeLEDsDetailsTablenot-accessiblemandatoryTable of blade LEDs detailed information. NOTE: Querying objects in this table may take significantly longer than normal, so it is recommended that the query t…
1.3.6.1.4.1.2.3.51.2.2.8.2.2.1RowbladeLEDsDetailsEntrynot-accessiblemandatoryBlade LEDs Details entry
1.3.6.1.4.1.2.3.51.2.2.8.2.2.1.1ColumnledIndexread-onlymandatoryThe LED index number.
1.3.6.1.4.1.2.3.51.2.2.8.2.2.1.2ColumnledBladeBayNumberread-onlymandatoryThe bay number of the main server blade that the LED is grouped into.
1.3.6.1.4.1.2.3.51.2.2.8.2.2.1.3ColumnledBladeComponentTyperead-onlymandatoryType of the component/subcomponent grouping for this LED.
1.3.6.1.4.1.2.3.51.2.2.8.2.2.1.4ColumnledBladeLabelread-onlymandatoryText label for a LED.
1.3.6.1.4.1.2.3.51.2.2.8.2.2.1.5ColumnledBladeStateread-onlymandatoryText description which denotes color or on/off/blink state for a LED.
1.3.6.1.4.1.2.3.51.2.2.8.2.2.1.6ColumnledBladeLocationread-onlymandatoryLocation of this LED.
1.3.6.1.4.1.2.3.51.2.2.8.4NodesmLEDs
1.3.6.1.4.1.2.3.51.2.2.8.4.2TablesmLEDsTablenot-accessiblemandatoryTable of switch module LEDs information.
1.3.6.1.4.1.2.3.51.2.2.8.4.2.1RowsmLEDsEntrynot-accessiblemandatorySwitch module LEDs information entry
1.3.6.1.4.1.2.3.51.2.2.8.4.2.1.1ColumnledSMIndexread-onlymandatorySwitch module LEDs table index.
1.3.6.1.4.1.2.3.51.2.2.8.4.2.1.2ColumnledSMSlotread-onlymandatoryThe bay number of the switch.
1.3.6.1.4.1.2.3.51.2.2.8.4.2.1.3ColumnledSMLabelread-onlymandatoryThe name associated with the LED.
1.3.6.1.4.1.2.3.51.2.2.8.4.2.1.4ColumnledSMStateread-writemandatoryNOTE: This table entry is read-write ONLY when Label = 'Enclosure Identity'. All other Label values have read-only access.
1.3.6.1.4.1.2.3.51.2.2.8.4.2.1.5ColumnledSMLocationread-onlymandatoryThe physical location where the LED can be found on the Switch.
1.3.6.1.4.1.2.3.51.2.2.8.5NodechassisFanLEDs
1.3.6.1.4.1.2.3.51.2.2.8.5.1TablechassisFanLEDsTablenot-accessiblemandatoryTable of chassis fan LEDs information.
1.3.6.1.4.1.2.3.51.2.2.8.5.1.1RowchassisFanLEDsEntrynot-accessiblemandatoryChassis fan LEDs information entry
1.3.6.1.4.1.2.3.51.2.2.8.5.1.1.1ColumnledChassisFanIndexread-onlymandatoryChassis fan LEDs table index.
1.3.6.1.4.1.2.3.51.2.2.8.5.1.1.2ColumnledChassisFanIdread-onlymandatoryThe numeric chassis fan ID.
1.3.6.1.4.1.2.3.51.2.2.8.5.1.1.3ColumnledChassisFanExistsread-onlymandatoryIndicates whether the chassis fan specified exists or not.
1.3.6.1.4.1.2.3.51.2.2.8.5.1.1.4ColumnledChassisFanErrorread-onlymandatoryIndicates whether the chassis fan error LED is on, off, or not available.
1.3.6.1.4.1.2.3.51.2.2.8.6NodefanPackLEDs
1.3.6.1.4.1.2.3.51.2.2.8.6.1TablefanPackLEDsTablenot-accessibledeprecatedTable of fan pack LEDs information. This table is deprecated because the LEDs for the power modules' fans are no longer on the fan packs, the LEDs are on the p…
1.3.6.1.4.1.2.3.51.2.2.8.6.1.1RowfanPackLEDsEntrynot-accessibledeprecatedFan Pack LEDs information entry
1.3.6.1.4.1.2.3.51.2.2.8.6.1.1.1ColumnledFanPackIndexread-onlydeprecatedFan Pack LEDs table index.
1.3.6.1.4.1.2.3.51.2.2.8.6.1.1.2ColumnledFanPackIdread-onlydeprecatedThe numeric fan pack ID.
1.3.6.1.4.1.2.3.51.2.2.8.6.1.1.3ColumnledFanPackExistsread-onlydeprecatedIndicates whether the fan pack specified exists or not.
1.3.6.1.4.1.2.3.51.2.2.8.6.1.1.4ColumnledFanPackErrorread-onlydeprecatedIndicates whether the fan pack error LED is on or off.
1.3.6.1.4.1.2.3.51.2.2.10NodefuelGauge
1.3.6.1.4.1.2.3.51.2.2.10.1NodefuelGaugeInformation
1.3.6.1.4.1.2.3.51.2.2.10.1.1TablefuelGaugeTablenot-accessiblemandatoryTable of Fuel Gauge information.
1.3.6.1.4.1.2.3.51.2.2.10.1.1.1RowfuelGaugeEntrynot-accessiblemandatoryFuel Gauge entry
1.3.6.1.4.1.2.3.51.2.2.10.1.1.1.1ColumnfuelGaugeIndexread-onlymandatoryFuel Gauge Table Index.
1.3.6.1.4.1.2.3.51.2.2.10.1.1.1.2ColumnfuelGaugePowerDomainNumberread-onlymandatoryFuel Gauge Table Power Domain Number.
1.3.6.1.4.1.2.3.51.2.2.10.1.1.1.3ColumnfuelGaugeStatusread-onlymandatoryFuel Gauge Table Status for the power domain. The response will start out with a numeric value (0 = unknown, 1 = good, 2 = warning, and 3: bad), followed by a …
1.3.6.1.4.1.2.3.51.2.2.10.1.1.1.4ColumnfuelGaugePowerModulesread-onlymandatoryFuel Gauge Table Power Module capacity in Watts in the power domain.
1.3.6.1.4.1.2.3.51.2.2.10.1.1.1.6ColumnfuelGaugePowerManagementPolicySettingread-onlymandatoryPower Management Policy Setting for each power domain. A new powerPolicyTable has been added which provides more detailed information regarding a domains power…
1.3.6.1.4.1.2.3.51.2.2.10.1.1.1.7ColumnfuelGaugeTotalPowerread-onlymandatoryThis field displays the total available power for each power domain based on installed power modules and the current Power Management Policy Setting.
1.3.6.1.4.1.2.3.51.2.2.10.1.1.1.8ColumnfuelGaugeAllocatedPowerread-onlymandatoryThis field displays the power that has been reserved in each power domain.
1.3.6.1.4.1.2.3.51.2.2.10.1.1.1.9ColumnfuelGaugeRemainingPowerread-onlymandatoryThis field displays the remaining power available in each domain. Remaining Power = Total Power minus Power In Use
1.3.6.1.4.1.2.3.51.2.2.10.1.1.1.10ColumnfuelGaugePowerInUsedread-onlymandatoryThis field displays the total power being used in each power domain.
1.3.6.1.4.1.2.3.51.2.2.10.2NodepowerDomain1
1.3.6.1.4.1.2.3.51.2.2.10.2.1TablepowerDomain1Tablenot-accessiblemandatoryTable of Power Domain 1.
1.3.6.1.4.1.2.3.51.2.2.10.2.1.1RowpowerDomain1Entrynot-accessiblemandatoryFuel Gauge entry
1.3.6.1.4.1.2.3.51.2.2.10.2.1.1.1Columnpd1Indexread-onlymandatoryPower Domain 1 Table Index.
1.3.6.1.4.1.2.3.51.2.2.10.2.1.1.2Columnpd1BayNumberread-onlymandatoryPower Domain 1 Table Bay Number. The following Bay Number IDs are used: notApplicable(1), notApplicable(2), fanPackBay1(3), fanPackBay2(4), fanPackBay3(5), fan…
1.3.6.1.4.1.2.3.51.2.2.10.2.1.1.3Columnpd1BladePrimarySlotread-onlymandatoryPower Domain 1 Table Blade Primary Slot can be useful when a server blade spans multiple slots (e.g. double wide or triple wide). For example if the blade is d…
1.3.6.1.4.1.2.3.51.2.2.10.2.1.1.4Columnpd1ModuleStatusread-onlymandatoryPower Domain 1 Table Module Throttle Status.
1.3.6.1.4.1.2.3.51.2.2.10.2.1.1.5Columnpd1ModuleNameread-onlymandatoryPower Domain 1 Table Module Name.
1.3.6.1.4.1.2.3.51.2.2.10.2.1.1.6Columnpd1ModuleStateread-onlymandatoryPower Domain 1 Table Module State.
1.3.6.1.4.1.2.3.51.2.2.10.2.1.1.7Columnpd1ModuleAllocatedPowerCurrentread-onlymandatoryPower Domain 1 Table Allocated Power Current indicates the current power allocation for the module in Watts. NOTE: When a server blade spans multiple slots (e.…
1.3.6.1.4.1.2.3.51.2.2.10.2.1.1.8Columnpd1ModuleAllocatedPowerMaxread-onlymandatoryPower Domain 1 Table Allocated Power Max indicates the maximum power allocation for the module in Watts. It is indicative of the maximum amount of power the mo…
1.3.6.1.4.1.2.3.51.2.2.10.2.1.1.9Columnpd1ModuleAllocatedPowerMinread-onlymandatoryPower Domain 1 Table Allocated Power Min indicates the minumum power allocation for the module in Watts. It is indicative of the minumum power consumption of t…
1.3.6.1.4.1.2.3.51.2.2.10.2.1.1.10Columnpd1ModuleCPUDutyCyclesread-onlymandatoryPower Domain 1 Table Module CPUs Duty Cycles applies to blade servers only. It displays the duty cycle for each CPU on the blade as a percentage. Note that som…
1.3.6.1.4.1.2.3.51.2.2.10.2.1.1.11Columnpd1ModuleThrottleread-onlymandatoryPower Domain 1 Table Module Throttle indicates whether the server blade may be allowed to throttle or not.
1.3.6.1.4.1.2.3.51.2.2.10.2.1.1.12Columnpd1ModulePowerCapabilitiesread-onlymandatoryPower Domain 1 Table Module Power Capabilities. staticPowerManagement: the module with the static worst case power values. fixedPowermanagement: the module wit…
1.3.6.1.4.1.2.3.51.2.2.10.2.1.1.13Columnpd1ModuleMeasuredOrStaticread-onlymandatoryPower Domain 1 Table Module Measured Or Static.
1.3.6.1.4.1.2.3.51.2.2.10.2.1.1.14Columnpd1TopologyPathread-onlymandatoryThe topology path for the component in this table. The chassis and each installed component is represented by a hardware topology tree, where each node in the …
1.3.6.1.4.1.2.3.51.2.2.10.2.3NodepowerDomain1PowerTrending
1.3.6.1.4.1.2.3.51.2.2.10.2.3.1Scalarpd1PowerTrendingPeriodread-writemandatorySpecify time period for power domain 1 power trending information table view. NOTE: This time period should be configured before displaying the following Power…
1.3.6.1.4.1.2.3.51.2.2.10.2.3.10Tablepd1PowerTrendingSampleTablenot-accessiblemandatoryTable of Power Domain 1 Power Trending Information.
1.3.6.1.4.1.2.3.51.2.2.10.2.3.10.1Rowpd1PowerTrendingSampleEntrynot-accessiblemandatoryPower Domain 1 Power Trending Sample entry.
1.3.6.1.4.1.2.3.51.2.2.10.2.3.10.1.1Columnpd1PowerTrendingSampleIndexread-onlymandatoryPower Domain 1 Power Trending Sample Table Index.
1.3.6.1.4.1.2.3.51.2.2.10.2.3.10.1.2Columnpd1PowerTrendingSampleTimeStampread-onlymandatoryPower Domain 1 Power Trending Sample Table Timestamp.
1.3.6.1.4.1.2.3.51.2.2.10.2.3.10.1.3Columnpd1PowerTrendingSampleAveread-onlymandatoryPower Domain 1 Power Trending Table Average Power.
1.3.6.1.4.1.2.3.51.2.2.10.4NodemoduleInformation
1.3.6.1.4.1.2.3.51.2.2.10.4.1NodebladeDetails
1.3.6.1.4.1.2.3.51.2.2.10.4.1.1TablebladeDetailsTablenot-accessiblemandatoryTable of Blade Module Details.
1.3.6.1.4.1.2.3.51.2.2.10.4.1.1.1RowbladeDetailsEntrynot-accessiblemandatoryBlade Module Details entry.
1.3.6.1.4.1.2.3.51.2.2.10.4.1.1.1.1ColumnbladeDetailsIndexread-onlymandatoryBlade Module Details Table Index.
1.3.6.1.4.1.2.3.51.2.2.10.4.1.1.1.2ColumnbladeDetailsIdread-onlymandatoryBlade Module Details Table Blade Id.
1.3.6.1.4.1.2.3.51.2.2.10.4.1.1.1.3ColumnbladeDetailsMaxPowerConfigread-writemandatoryBlade Module Details Table Maximum Power Configuration. Allow the user to set the maximum power that can be used by the blade. This function is also known as p…
1.3.6.1.4.1.2.3.51.2.2.10.4.1.1.1.4ColumnbladeDetailsEffectiveClockRateread-onlymandatoryBlade Module Details Table Effective CPU Clock Rate applies to DPM blades only. It displays processor's effective clock rate based on sample interval. Note tha…
1.3.6.1.4.1.2.3.51.2.2.10.4.1.1.1.5ColumnbladeDetailsMaximumClockRateread-onlymandatoryBlade Module Details Table Maximum CPU Clock Rate applies to DPM blades only. It displays processor's maximum clock rate based on sample interval. Note that so…
1.3.6.1.4.1.2.3.51.2.2.10.4.1.1.1.6ColumnbladeDetailsPowerSaverModeread-writemandatoryWhen enabled, the static low power saver mode allows the blade to selectively alter its operating voltage and frequency to reduce power consumption. This featu…
1.3.6.1.4.1.2.3.51.2.2.10.4.1.1.1.7ColumnbladeDetailsDynamicPowerSaverread-writemandatoryWhen enabled, Dynamic Power Saver allows the voltage and frequency of the CPUs on the blade to be controlled based on how busy the CPU is. This feature is not …
1.3.6.1.4.1.2.3.51.2.2.10.4.1.1.1.8ColumnbladeDetailsDynamicPowerFavorPerformanceOverPowerread-writemandatoryWhen enabled, Dynamic Power Favor Performance Over Power supports a max performance mode that pushes the system past its nominal CPU frequency when CPU and mem…
1.3.6.1.4.1.2.3.51.2.2.10.4.1.1.1.9ColumnbladeDetailsPowerControlread-writemandatoryThis object is used to get or set the power control setting on a blade. If dynamic power mgmt is not supported on a blade, notApplicable(255) will be returned.…
1.3.6.1.4.1.2.3.51.2.2.10.4.1.1.1.10ColumnbladeDetailsPcapMinread-onlymandatoryBlade Module Details Table power capping Minimum value in watts. The blade must support the advanced power management feature. If the value of Pcap Min is 'not…
1.3.6.1.4.1.2.3.51.2.2.10.4.1.1.1.11ColumnbladeDetailsPcapGuaranteedMinread-onlymandatoryBlade Module Details Table power capping Guaranteed Minimum value in watts. The blade must support the advanced power management feature. If the value of Pcap …
1.3.6.1.4.1.2.3.51.2.2.10.4.1.1.1.12ColumnbladeDetailsPcapMaxread-onlymandatoryBlade Module Details Table power capping Maximum value in watts. The blade must support the advanced power management feature. If the value is '<max1> Watts,<m…
1.3.6.1.4.1.2.3.51.2.2.10.4.1.3NodebladePowerTrending
1.3.6.1.4.1.2.3.51.2.2.10.4.1.3.1ScalarbladePowerTrendingPeriodread-writemandatorySpecify time period for blade module power trending information table view. NOTE: This time period should be configured before displaying the following Power T…
1.3.6.1.4.1.2.3.51.2.2.10.4.1.3.2ScalarbladePowerTrendingBladeIdread-writemandatoryBlade Module Power Trending Blade Id. NOTE: The Blade Id should be configured before displaying the bladePowerTrendingTable.
1.3.6.1.4.1.2.3.51.2.2.10.4.1.3.3ScalarbladePowerTrendingTopologyPathread-writemandatory
1.3.6.1.4.1.2.3.51.2.2.10.4.1.3.10TablebladePowerTrendingSampleTablenot-accessiblemandatoryTable of Blade Module Power Trending Information. Since the power trending data is constantly being computed and saved in the management application database, …
1.3.6.1.4.1.2.3.51.2.2.10.4.1.3.10.1RowbladePowerTrendingSampleEntrynot-accessiblemandatoryBlade Module Power Trending Sample entry.
1.3.6.1.4.1.2.3.51.2.2.10.4.1.3.10.1.1ColumnbladePowerTrendingSampleIndexread-onlymandatoryBlade Module Power Trending Sample Table Index.
1.3.6.1.4.1.2.3.51.2.2.10.4.1.3.10.1.2ColumnbladePowerTrendingSampleIdread-onlymandatoryBlade Module Power Trending Sample Table Blade Id. If the blade is defined using a topology location by using the scalar bladePowerTrendingTopologyPath, a zero…
1.3.6.1.4.1.2.3.51.2.2.10.4.1.3.10.1.3ColumnbladePowerTrendingSampleTimeStampread-onlymandatoryBlade Module Power Trending Sample Table Timestamp.
1.3.6.1.4.1.2.3.51.2.2.10.4.1.3.10.1.4ColumnbladePowerTrendingSampleMaxread-onlymandatoryBlade Module Power Trending Sample Table Maximum Power.
1.3.6.1.4.1.2.3.51.2.2.10.4.1.3.10.1.5ColumnbladePowerTrendingSampleMinread-onlymandatoryBlade Module Power Trending Sample Table Minimum Power.
1.3.6.1.4.1.2.3.51.2.2.10.4.1.3.10.1.6ColumnbladePowerTrendingSampleAveread-onlymandatoryBlade Module Power Trending Sample Table Average Power.
1.3.6.1.4.1.2.3.51.2.2.10.4.1.3.10.1.7ColumnbladePowerTrendingSampleTopologyIdread-onlymandatoryBlade module topology path. This field will have a topology location when a blade is a storage blade or a blade defined with a sub chassis. If the blade is def…
1.3.6.1.4.1.2.3.51.2.2.10.4.2NodeswitchDetails
1.3.6.1.4.1.2.3.51.2.2.10.4.2.3NodeswitchPowerTrending
1.3.6.1.4.1.2.3.51.2.2.10.4.2.3.1ScalarswitchPowerTrendingPeriodread-writemandatorySpecify time period for switch module power trending information table view. NOTE: This time period should be configured before displaying the following Power …
1.3.6.1.4.1.2.3.51.2.2.10.4.2.3.2ScalarswitchPowerTrendingSwitchIdread-writemandatorySwitch Module Power Trending Switch Id. NOTE: The Switch Id should be configured before displaying the switchPowerTrendingTable.
1.3.6.1.4.1.2.3.51.2.2.10.4.2.3.10TableswitchPowerTrendingSampleTablenot-accessiblemandatoryTable of Switch Module Power Trending Information.
1.3.6.1.4.1.2.3.51.2.2.10.4.2.3.10.1RowswitchPowerTrendingSampleEntrynot-accessiblemandatorySwitch Module Power Trending Sample entry.
1.3.6.1.4.1.2.3.51.2.2.10.4.2.3.10.1.1ColumnswitchPowerTrendingSampleIndexread-onlymandatorySwitch Module Power Trending Sample Table Index.
1.3.6.1.4.1.2.3.51.2.2.10.4.2.3.10.1.2ColumnswitchPowerTrendingSampleIdread-onlymandatorySwitch Module Power Trending Sample Table Switch Id.
1.3.6.1.4.1.2.3.51.2.2.10.4.2.3.10.1.3ColumnswitchPowerTrendingSampleTimeStampread-onlymandatorySwitch Module Power Trending Sample Table Timestamp.
1.3.6.1.4.1.2.3.51.2.2.10.4.2.3.10.1.4ColumnswitchPowerTrendingSampleMaxread-onlymandatorySwitch Module Power Trending Sample Table Maximum Power.
1.3.6.1.4.1.2.3.51.2.2.10.4.2.3.10.1.5ColumnswitchPowerTrendingSampleMinread-onlymandatorySwitch Module Power Trending Sample Table Minimum Power.
1.3.6.1.4.1.2.3.51.2.2.10.4.2.3.10.1.6ColumnswitchPowerTrendingSampleAveread-onlymandatorySwitch Module Power Trending Sample Table Average Power.
1.3.6.1.4.1.2.3.51.2.2.10.4.3NodechassisFanDetails
1.3.6.1.4.1.2.3.51.2.2.10.4.3.3NodechassisFanPowerTrending
1.3.6.1.4.1.2.3.51.2.2.10.4.3.3.1ScalarchassisFanPowerTrendingPeriodread-writemandatorySpecify time period for chassis fan module power trending information table view. NOTE: This time period should be configured before displaying the following P…
1.3.6.1.4.1.2.3.51.2.2.10.4.3.3.2ScalarchassisFanPowerTrendingIdread-writemandatoryChass fan mModule power trending fan ID. NOTE: The ID should be configured before displaying the chassisFanPowerTrendingTable.
1.3.6.1.4.1.2.3.51.2.2.10.4.3.3.10TablechassisFanPowerTrendingSampleTablenot-accessiblemandatoryTable of chassis fan Module Power Trending Information.
1.3.6.1.4.1.2.3.51.2.2.10.4.3.3.10.1RowchassisFanPowerTrendingSampleEntrynot-accessiblemandatoryChassis fan Module Power Trending Sample entry.
1.3.6.1.4.1.2.3.51.2.2.10.4.3.3.10.1.1ColumnchassisFanPowerTrendingSampleIndexread-onlymandatoryChassis fan Module Power Trending Sample Table Index.
1.3.6.1.4.1.2.3.51.2.2.10.4.3.3.10.1.2ColumnchassisFanPowerTrendingSampleIdread-onlymandatoryChassis fan Module Power Trending Sample Table Id.
1.3.6.1.4.1.2.3.51.2.2.10.4.3.3.10.1.3ColumnchassisFanPowerTrendingSampleTimeStampread-onlymandatoryChassis fan Module Power Trending Sample Table Timestamp.
1.3.6.1.4.1.2.3.51.2.2.10.4.3.3.10.1.4ColumnchassisFanPowerTrendingSampleMaxread-onlymandatoryChassis fan Module Power Trending Sample Table Maximum Power.
1.3.6.1.4.1.2.3.51.2.2.10.4.3.3.10.1.5ColumnchassisFanPowerTrendingSampleMinread-onlymandatoryChassis fan Module Power Trending Sample Table Minimum Power.
1.3.6.1.4.1.2.3.51.2.2.10.4.3.3.10.1.6ColumnchassisFanPowerTrendingSampleAveread-onlymandatoryChassis fan Module Power Trending Sample Table Average Power.
1.3.6.1.4.1.2.3.51.2.2.10.5NodechassisInformation
1.3.6.1.4.1.2.3.51.2.2.10.5.1NodechassisConfiguration
1.3.6.1.4.1.2.3.51.2.2.10.5.1.1ScalarchassisTotalDCPowerAvailableread-onlymandatoryChassis total DC power available, which displays the total DC power available for the entire chassis. It is the sum of the two power domains.
1.3.6.1.4.1.2.3.51.2.2.10.5.1.2ScalarchassisTotalPowerInUsedread-onlymandatoryChassis total power being used, which displays the total power being consumed by all modules in the chassis. It also includes power consumed by the blowers (ch…
1.3.6.1.4.1.2.3.51.2.2.10.5.1.3ScalarchassisTotalThermalOutputread-onlymandatoryChassis total thermal output, which displays the thermal output (load) in BTUs per hour. It is calculated based on the total input power in use. (1 Watt = 3.41…
1.3.6.1.4.1.2.3.51.2.2.10.5.1.5ScalarchassisPowerServiceread-onlydeprecatedThe chassis power service mode. NOTE: This MIB object is for BCS only. This object has been deprecated. See the object, powerModuleDescription, for similar inf…
1.3.6.1.4.1.2.3.51.2.2.10.5.3NodechassisPowerTrending
1.3.6.1.4.1.2.3.51.2.2.10.5.3.1ScalarchassisPowerTrendingPeriodread-writemandatorySpecify time period of power trending information. NOTE: This time period should be configured before displaying the following Power Trending Information table…
1.3.6.1.4.1.2.3.51.2.2.10.5.3.10TablechassisPowerTrendingSampleTablenot-accessiblemandatoryTable of Chassis Power Trending Sample Information in specified time period.
1.3.6.1.4.1.2.3.51.2.2.10.5.3.10.1RowchassisPowerTrendingSampleEntrynot-accessiblemandatoryChassis Power Trending Sample entry in specified time period.
1.3.6.1.4.1.2.3.51.2.2.10.5.3.10.1.1ColumnchassisPowerTrendingSampleIndexread-onlymandatoryChassis Power Trending Sample Index in specified time period.
1.3.6.1.4.1.2.3.51.2.2.10.5.3.10.1.2ColumnchassisPowerTrendingSampleTimeStampread-onlymandatoryChassis Power Trending Sample Timestamp in specified time period.
1.3.6.1.4.1.2.3.51.2.2.10.5.3.10.1.3ColumnchassisPowerTrendingSampleAveread-onlymandatoryChassis Power Trending Sample Average Power in specified time period.
1.3.6.1.4.1.2.3.51.2.2.10.5.5NodechassisThermalTrending
1.3.6.1.4.1.2.3.51.2.2.10.5.5.1ScalarchassisThermalTrendingPeriodread-writemandatorySpecify time period of thermal trending information. NOTE: This time period should be configured before displaying the following Thermal Trending Information t…
1.3.6.1.4.1.2.3.51.2.2.10.5.5.10TablerearLEDCardThermalTrendingTablenot-accessiblemandatoryTable of rear LED card Thermal Trending Information.
1.3.6.1.4.1.2.3.51.2.2.10.5.5.10.1RowrearLEDCardThermalTrendingEntrynot-accessiblemandatoryRear LED Card Thermal Trending entry.
1.3.6.1.4.1.2.3.51.2.2.10.5.5.10.1.1ColumnrearLEDCardThermalTrendingIndexread-onlymandatoryRear LED Card Thermal Trending Table Index.
1.3.6.1.4.1.2.3.51.2.2.10.5.5.10.1.2ColumnrearLEDCardThermalTrendingTimeStampread-onlymandatoryRear LED Card Thermal Trending Table Sample Timestamp.
1.3.6.1.4.1.2.3.51.2.2.10.5.5.10.1.3ColumnrearLEDCardThermalTrendingTemperatureAvgread-onlymandatoryRear LED Card Thermal Trending Table Average Temperature.
1.3.6.1.4.1.2.3.51.2.2.10.5.5.10.1.4ColumnrearLEDCardThermalTrendingTemperatureMinread-onlymandatoryRear LED Card Thermal Trending Table Minumum Temperature.
1.3.6.1.4.1.2.3.51.2.2.10.5.5.10.1.5ColumnrearLEDCardThermalTrendingTemperatureMaxread-onlymandatoryRear LED Card Thermal Trending Table Maximum Temperature.
1.3.6.1.4.1.2.3.51.2.2.10.5.5.60TablecfmThermalTrendingTablenot-accessiblemandatoryTable of Cubic Feet per Minute Thermal Trending Information.
1.3.6.1.4.1.2.3.51.2.2.10.5.5.60.1RowcfmThermalTrendingEntrynot-accessiblemandatoryChassis CFM Thermal Trending entry.
1.3.6.1.4.1.2.3.51.2.2.10.5.5.60.1.1ColumncfmThermalTrendingIndexread-onlymandatoryCubic Feet per Minute Thermal Trending Table Index.
1.3.6.1.4.1.2.3.51.2.2.10.5.5.60.1.2ColumncfmThermalTrendingTimeStampread-onlymandatoryCubic Feet per Minute Thermal Trending Table Sample Timestamp.
1.3.6.1.4.1.2.3.51.2.2.10.5.5.60.1.3ColumncfmThermalTrendingCurrentCFMread-onlymandatoryCubic Feet per Minute Thermal Trending Table The Current CFM of air flow calculated at this sample time.
1.3.6.1.4.1.2.3.51.2.2.10.5.5.60.1.4ColumncfmThermalTrendingMaxCFMread-onlymandatoryCubic Feet per Minute Thermal Trending Table The Maximum CFM of air flow the chassis can provide at this sample time.
1.3.6.1.4.1.2.3.51.2.2.10.5.5.70TableehiThermalTrendingTablenot-accessiblemandatoryTable of Exhaust Heat Index Thermal Trending Information.
1.3.6.1.4.1.2.3.51.2.2.10.5.5.70.1RowehiThermalTrendingEntrynot-accessiblemandatoryChassis Exhaust Heat Index Thermal Trending entry.
1.3.6.1.4.1.2.3.51.2.2.10.5.5.70.1.1ColumnehiThermalTrendingIndexread-onlymandatoryExhaust Heat Index Thermal Trending Table Index.
1.3.6.1.4.1.2.3.51.2.2.10.5.5.70.1.2ColumnehiThermalTrendingTimeStampread-onlymandatoryChassis Exhaust Heat Index Thermal Trending Table Sample Timestamp.
1.3.6.1.4.1.2.3.51.2.2.10.5.5.70.1.3ColumnehiThermalTrendingMinEHIread-onlymandatoryChassis Exhaust Heat Index Thermal Trending Table Minimum Exhaust Heat Index since last reboot.
1.3.6.1.4.1.2.3.51.2.2.10.5.5.70.1.4ColumnehiThermalTrendingMaxEHIread-onlymandatoryChassis Exhaust Heat Index Thermal Trending Table Maximum Exhaust Heat Index since last reboot.
1.3.6.1.4.1.2.3.51.2.2.10.5.5.70.1.5ColumnehiThermalTrendingAvgEHIread-onlymandatoryChassis Exhaust Heat Index Thermal Trending Table Average of last 2 Exhaust Heat Index calculations since last reboot.
1.3.6.1.4.1.2.3.51.2.2.10.6NodepowerPolicyInformation
1.3.6.1.4.1.2.3.51.2.2.10.6.1TablepowerPolicyTablenot-accessiblemandatoryTable of Power Policy information for all power domains. Reading this table can tell you about the available power policies that can be configured for a domain…
1.3.6.1.4.1.2.3.51.2.2.10.6.1.1RowpowerPolicyEntrynot-accessiblemandatoryPower Policy Entry
1.3.6.1.4.1.2.3.51.2.2.10.6.1.1.1ColumnpowerPolicyIndexread-onlymandatoryThe unique idenitifier of a row in the powerPolicyTable.
1.3.6.1.4.1.2.3.51.2.2.10.6.1.1.2ColumnpowerPolicyPowerDomainNumberread-onlymandatoryThe power domain number which this row is associated with.
1.3.6.1.4.1.2.3.51.2.2.10.6.1.1.3ColumnpowerPolicyNameread-onlymandatoryThe short name of the power policy. The following are the possible names and their detailed description: Power Module Redundancy Intended for a single power so…
1.3.6.1.4.1.2.3.51.2.2.10.6.1.1.4ColumnpowerPolicyPwrSupplyFailureLimitread-onlymandatoryThe maximum number of power supplies that can fail in a chassis while still providing redundancy.
1.3.6.1.4.1.2.3.51.2.2.10.6.1.1.5ColumnpowerPolicyMaxPowerLimitread-onlymandatoryThe maximum power available (in watts), based on the number of power modules and the Power Management Policy setting.
1.3.6.1.4.1.2.3.51.2.2.10.6.1.1.6ColumnpowerPolicyEstimatedUtilizationread-onlymandatoryThe estimated utilization (as a percentage) based on current power usage.
1.3.6.1.4.1.2.3.51.2.2.10.6.1.1.7ColumnpowerPolicyActivateread-writemandatoryWhen read, this object provides the status of this power policy. If the value is enabled(1), it means this is the active power policy for the associated domain…
1.3.6.1.4.1.2.3.51.2.2.17Nodeusers
1.3.6.1.4.1.2.3.51.2.2.17.1NodemmUsers
1.3.6.1.4.1.2.3.51.2.2.17.1.1TablecurrentlyLoggedInTablenot-accessiblemandatoryTable of MM users currently logged in.
1.3.6.1.4.1.2.3.51.2.2.17.1.1.1RowcurrentlyLoggedInEntrynot-accessiblemandatoryMM users currently logged in entries.
1.3.6.1.4.1.2.3.51.2.2.17.1.1.1.1ColumncurrentlyLoggedInEntryIndexread-onlymandatoryIndex for MM users currently logged in.
1.3.6.1.4.1.2.3.51.2.2.17.1.1.1.2ColumncurrentlyLoggedInEntryUserIdread-onlymandatoryName for MM users currently logged in. NOTE: 'Default SNMPv1 user' indicates an internal user used by SNMPv1 agent.
1.3.6.1.4.1.2.3.51.2.2.17.1.1.1.3ColumncurrentlyLoggedInEntryAccMethodread-onlymandatoryAccess method for MM users currently logged in.
1.3.6.1.4.1.2.3.51.2.2.21NodevpdInformation
1.3.6.1.4.1.2.3.51.2.2.21.1NodechassisInfoVpd
1.3.6.1.4.1.2.3.51.2.2.21.1.1NodechassisVpd
1.3.6.1.4.1.2.3.51.2.2.21.1.1.1ScalarchassisVpdMachineTyperead-writedeprecatedMachine type VPD information (from System BIOS). This field must be four alpha numeric characters.
1.3.6.1.4.1.2.3.51.2.2.21.1.1.2ScalarchassisVpdMachineModelread-writedeprecatedMachine model VPD information (from System BIOS). This field must be three alpha numeric characters.
1.3.6.1.4.1.2.3.51.2.2.21.1.1.3ScalarchassisSerialNumberread-writedeprecatedMachine serial number VPD information (from System BIOS). This field must be seven alpha numeric characters.
1.3.6.1.4.1.2.3.51.2.2.21.1.1.4ScalarchassisUUIDread-writedeprecatedMachine UUID (Universal Unique ID information) (from System BIOS). This field must be 32 alpha numeric characters.
1.3.6.1.4.1.2.3.51.2.2.21.1.1.5ScalarchassisManufacturingIdread-onlydeprecatedMachine chassis manufacturing ID.
1.3.6.1.4.1.2.3.51.2.2.21.1.1.6ScalarchassisHardwareRevisionread-onlydeprecatedMachine chassis hardware revision. If a hardware revision is programmed in the OEM VPD area for this component, then the HardwareRevisionString version of this…
1.3.6.1.4.1.2.3.51.2.2.21.1.1.7ScalarchassisFruNumberread-onlydeprecatedMachine chassis FRU number.
1.3.6.1.4.1.2.3.51.2.2.21.1.1.8ScalarchassisManufDateread-onlydeprecatedMachine chassis manufacture date.
1.3.6.1.4.1.2.3.51.2.2.21.1.1.9ScalarchassisPartNumberread-onlydeprecatedMachine chassis part number.
1.3.6.1.4.1.2.3.51.2.2.21.1.1.10ScalarchassisFruSerialread-onlydeprecatedMachine chassis FRU serial number.
1.3.6.1.4.1.2.3.51.2.2.21.1.1.11ScalarchassisManufacturingIDNumberread-onlydeprecatedMachine chassis manufacturer ID Number.
1.3.6.1.4.1.2.3.51.2.2.21.1.1.12ScalarchassisProductIdread-onlydeprecatedMachine chassis product ID.
1.3.6.1.4.1.2.3.51.2.2.21.1.1.13ScalarchassisSubManufacturerIdread-onlydeprecatedMachine chassis subsystem manufacturer.
1.3.6.1.4.1.2.3.51.2.2.21.1.1.14ScalarchassisCleiread-onlydeprecatedMachine chassis Common Language Equipment Identification (CLEI).
1.3.6.1.4.1.2.3.51.2.2.21.1.1.16ScalarchassisHardwareRevisionStringread-onlydeprecatedMachine chassis hardware revision in string format. If a hardware revision is programmed in the OEM VPD area for this component, then this MIB object should be…
1.3.6.1.4.1.2.3.51.2.2.21.2NodemmHardwareVpd
1.3.6.1.4.1.2.3.51.2.2.21.2.1TablemmHardwareVpdTablenot-accessibledeprecatedTable of the management module hardware components. For consistent results, view as a table and not as individual entries.
1.3.6.1.4.1.2.3.51.2.2.21.2.1.1RowmmHardwareVpdEntrynot-accessibledeprecatedManagement module hardware VPD entry. For consistent results, view as a table and not as individual entries.
1.3.6.1.4.1.2.3.51.2.2.21.2.1.1.1ColumnmmHardwareVpdIndexread-onlydeprecatedManagement module hardware VPD index. For consistent results, view as a table and not as individual entries.
1.3.6.1.4.1.2.3.51.2.2.21.2.1.1.2ColumnmmHardwareVpdBayNumberread-onlydeprecatedManagement module hardware VPD Bay number. For consistent results, view as a table and not as individual entries.
1.3.6.1.4.1.2.3.51.2.2.21.2.1.1.3ColumnmmHardwareVpdManufacturingIdread-onlydeprecatedManagement module hardware VPD manufacturing ID. For consistent results, view as a table and not as individual entries.
1.3.6.1.4.1.2.3.51.2.2.21.2.1.1.4ColumnmmHardwareVpdFruNumberread-onlydeprecatedManagement module hardware VPD FRU number. For consistent results, view as a table and not as individual entries.
1.3.6.1.4.1.2.3.51.2.2.21.2.1.1.5ColumnmmHardwareVpdHardwareRevisionread-onlydeprecatedManagement module hardware VPD hardware revision. For consistent results, view as a table and not as individual entries. If a hardware revision is programmed i…
1.3.6.1.4.1.2.3.51.2.2.21.2.1.1.6ColumnmmHardwareVpdUuidread-onlydeprecatedManagement module hardware VPD UUID. For consistent results, view as a table and not as individual entries.
1.3.6.1.4.1.2.3.51.2.2.21.2.1.1.7ColumnmmHardwareVpdManufDateread-onlydeprecatedManagement module hardware VPD manufacture date. For consistent results, view as a table and not as individual entries.
1.3.6.1.4.1.2.3.51.2.2.21.2.1.1.8ColumnmmHardwareVpdPartNumberread-onlydeprecatedManagement module hardware VPD Part number. For consistent results, view as a table and not as individual entries.
1.3.6.1.4.1.2.3.51.2.2.21.2.1.1.9ColumnmmHardwareVpdFruSerialread-onlydeprecatedManagement module hardware VPD FRU serial number. For consistent results, view as a table and not as individual entries.
1.3.6.1.4.1.2.3.51.2.2.21.2.1.1.10ColumnmmHardwareVpdManufacturingIDNumberread-onlydeprecatedManagement module hardware VPD manufacturer ID Number. For consistent results, view as a table and not as individual entries.
1.3.6.1.4.1.2.3.51.2.2.21.2.1.1.11ColumnmmHardwareVpdProductIdread-onlydeprecatedManagement module hardware VPD product ID. For consistent results, view as a table and not as individual entries.
1.3.6.1.4.1.2.3.51.2.2.21.2.1.1.12ColumnmmHardwareVpdSubManufacturerIdread-onlydeprecatedManagement module hardware VPD subsystem manufacturer. For consistent results, view as a table and not as individual entries.
1.3.6.1.4.1.2.3.51.2.2.21.2.1.1.13ColumnmmHardwareVpdCleiread-onlydeprecatedManagement module hardware VPD Common Language Equipment Identification (CLEI). For consistent results, view as a table and not as individual entries.
1.3.6.1.4.1.2.3.51.2.2.21.2.1.1.14ColumnmmHardwareVpdHardwareRevisionStringread-onlydeprecatedManagement module hardware VPD hardware revision in string format. For consistent results, view as a table and not as individual entries. If a hardware revisio…
1.3.6.1.4.1.2.3.51.2.2.21.3NodemmFirmwareVpd
1.3.6.1.4.1.2.3.51.2.2.21.3.1TablemmMainApplVpdTablenot-accessibledeprecatedTable of MM Firmware VPD.
1.3.6.1.4.1.2.3.51.2.2.21.3.1.1RowmmMainApplVpdEntrynot-accessibledeprecatedMM Firmware VPD entry.
1.3.6.1.4.1.2.3.51.2.2.21.3.1.1.1ColumnmmMainApplVpdIndexread-onlydeprecatedFirmware VPD index.
1.3.6.1.4.1.2.3.51.2.2.21.3.1.1.2ColumnmmMainApplVpdNameread-onlydeprecatedFirmware VPD name description. 'MM firmware' indicates the running firmware of the MM. 'MM firmware (pending restart)' indicates the flashed firmware of the MM…
1.3.6.1.4.1.2.3.51.2.2.21.3.1.1.3ColumnmmMainApplVpdBuildIdread-onlydeprecatedFirmware VPD build identification.
1.3.6.1.4.1.2.3.51.2.2.21.3.1.1.4ColumnmmMainApplVpdRevisonNumberread-onlydeprecatedFirmware VPD revision number.
1.3.6.1.4.1.2.3.51.2.2.21.3.1.1.5ColumnmmMainApplVpdFilenameread-onlydeprecatedFirmware VPD file name.
1.3.6.1.4.1.2.3.51.2.2.21.3.1.1.6ColumnmmMainApplVpdBuildDateread-onlydeprecatedFirmware VPD build date.
1.3.6.1.4.1.2.3.51.2.2.21.4NodebladeHardwareVpd
1.3.6.1.4.1.2.3.51.2.2.21.4.1TablebladeHardwareVpdTablenot-accessibledeprecatedTable of VPD information for the blade hardware components. For consistent results, view as a table and not as individual entries.
1.3.6.1.4.1.2.3.51.2.2.21.4.1.1RowbladeHardwareVpdEntrynot-accessibledeprecatedBlade hardware VPD entry. For consistent results, view as a table and not as individual entries.
1.3.6.1.4.1.2.3.51.2.2.21.4.1.1.1ColumnbladeHardwareVpdIndexread-onlydeprecatedBlade hardware VPD index. For consistent results, view as a table and not as individual entries.
1.3.6.1.4.1.2.3.51.2.2.21.4.1.1.2ColumnbladeHardwareVpdBayNumberread-onlydeprecatedBlade hardware VPD Bay number. For consistent results, view as a table and not as individual entries.
1.3.6.1.4.1.2.3.51.2.2.21.4.1.1.3ColumnbladeHardwareVpdManufacturingIdread-onlydeprecatedBlade hardware VPD manufacturing ID. For consistent results, view as a table and not as individual entries.
1.3.6.1.4.1.2.3.51.2.2.21.4.1.1.4ColumnbladeHardwareVpdFruNumberread-onlydeprecatedBlade hardware VPD FRU number. For consistent results, view as a table and not as individual entries.
1.3.6.1.4.1.2.3.51.2.2.21.4.1.1.5ColumnbladeHardwareVpdHardwareRevisionread-onlydeprecatedBlade hardware VPD hardware revision. For consistent results, view as a table and not as individual entries. If a hardware revision is programmed in the OEM VP…
1.3.6.1.4.1.2.3.51.2.2.21.4.1.1.6ColumnbladeHardwareVpdSerialNumberread-onlydeprecatedBlade hardware VPD serial number. For consistent results, view as a table and not as individual entries.
1.3.6.1.4.1.2.3.51.2.2.21.4.1.1.7ColumnbladeHardwareVpdMachineTyperead-onlydeprecatedBlade hardware VPD machine type. For consistent results, view as a table and not as individual entries.
1.3.6.1.4.1.2.3.51.2.2.21.4.1.1.8ColumnbladeHardwareVpdUuidread-onlydeprecatedBlade hardware VPD UUID. For consistent results, view as a table and not as individual entries.
1.3.6.1.4.1.2.3.51.2.2.21.4.1.1.9ColumnbladeHardwareVpdManufDateread-onlydeprecatedBlade hardware VPD Manufacture Date. For consistent results, view as a table and not as individual entries.
1.3.6.1.4.1.2.3.51.2.2.21.4.1.1.10ColumnbladeHardwareVpdPartNumberread-onlydeprecatedBlade hardware VPD Part number. For consistent results, view as a table and not as individual entries.
1.3.6.1.4.1.2.3.51.2.2.21.4.1.1.11ColumnbladeHardwareVpdFruSerialread-onlydeprecatedBlade hardware VPD FRU serial number. For consistent results, view as a table and not as individual entries.
1.3.6.1.4.1.2.3.51.2.2.21.4.1.1.12ColumnbladeHardwareVpdMachineModelread-onlydeprecatedBlade hardware VPD machine model. For consistent results, view as a table and not as individual entries.
1.3.6.1.4.1.2.3.51.2.2.21.4.1.1.13ColumnbladeHardwareVpdManufacturingIDNumberread-onlydeprecatedBlade hardware VPD Manufacturer ID Number. For consistent results, view as a table and not as individual entries.
1.3.6.1.4.1.2.3.51.2.2.21.4.1.1.14ColumnbladeHardwareVpdProductIdread-onlydeprecatedBlade hardware VPD product ID. For consistent results, view as a table and not as individual entries.
1.3.6.1.4.1.2.3.51.2.2.21.4.1.1.15ColumnbladeHardwareVpdSubManufacturerIdread-onlydeprecatedBlade hardware VPD subsystem manufacturer ID. For consistent results, view as a table and not as individual entries.
1.3.6.1.4.1.2.3.51.2.2.21.4.1.1.16ColumnbladeHardwareVpdCleiread-onlydeprecatedBlade hardware VPD Common Language Equipment Identifier (CLEI). For consistent results, view as a table and not as individual entries.
1.3.6.1.4.1.2.3.51.2.2.21.4.1.1.17ColumnbladeHardwareVpdHardwareRevisionStringread-onlydeprecatedBlade hardware VPD hardware revision in string format. For consistent results, view as a table and not as individual entries. If a hardware revision is program…
1.3.6.1.4.1.2.3.51.2.2.21.4.1.1.20ColumnbladeDaughterVpdCardTyperead-onlydeprecatedBlade expansion card (daughter card) VPD type. For consistent results, view as a table and not as individual entries.
1.3.6.1.4.1.2.3.51.2.2.21.4.1.1.21ColumnbladeDaughterVpdManufacturingIdread-onlydeprecatedBlade expansion card (daughter card) VPD manufacturing ID. For consistent results, view as a table and not as individual entries.
1.3.6.1.4.1.2.3.51.2.2.21.4.1.1.22ColumnbladeDaughterVpdFruNumberread-onlydeprecatedBlade expansion card (daughter card) VPD FRU number. For consistent results, view as a table and not as individual entries.
1.3.6.1.4.1.2.3.51.2.2.21.4.1.1.23ColumnbladeDaughterVpdHardwareRevisionread-onlydeprecatedBlade expansion card (daughter card) VPD hardware revision. For consistent results, view as a table and not as individual entries. If a hardware revision is pr…
1.3.6.1.4.1.2.3.51.2.2.21.4.1.1.24ColumnbladeDaughterVpdSerialNumberread-onlydeprecatedBlade expansion card (daughter card) VPD Serial number. For consistent results, view as a table and not as individual entries.
1.3.6.1.4.1.2.3.51.2.2.21.4.1.1.25ColumnbladeDaughterVpdMachineTyperead-onlydeprecatedBlade expansion card (daughter card) VPD Machine type. For consistent results, view as a table and not as individual entries.
1.3.6.1.4.1.2.3.51.2.2.21.4.1.1.26ColumnbladeDaughterVpdUuidread-onlydeprecatedBlade expansion card (daughter card) VPD UUID. For consistent results, view as a table and not as individual entries.
1.3.6.1.4.1.2.3.51.2.2.21.4.1.1.27ColumnbladeDaughterVpdManufDateread-onlydeprecatedBlade expansion card (daughter card) VPD Manufacture date. For consistent results, view as a table and not as individual entries.
1.3.6.1.4.1.2.3.51.2.2.21.4.1.1.28ColumnbladeDaughterVpdPartNumberread-onlydeprecatedBlade expansion card (daughter card) VPD Part number. For consistent results, view as a table and not as individual entries.
1.3.6.1.4.1.2.3.51.2.2.21.4.1.1.29ColumnbladeDaughterVpdFruSerialread-onlydeprecatedBlade expansion card (daughter card) VPD FRU Serial. For consistent results, view as a table and not as individual entries.
1.3.6.1.4.1.2.3.51.2.2.21.4.1.1.30ColumnbladeDaughterVpdManufacturingIDNumberread-onlydeprecatedBlade expansion card (daughter card) VPD manufacturer ID Number. For consistent results, view as a table and not as individual entries.
1.3.6.1.4.1.2.3.51.2.2.21.4.1.1.31ColumnbladeDaughterVpdProductIdread-onlydeprecatedBlade expansion card (daughter card) VPD product ID. For consistent results, view as a table and not as individual entries.
1.3.6.1.4.1.2.3.51.2.2.21.4.1.1.32ColumnbladeDaughterVpdSubManufacturerIdread-onlydeprecatedBlade expansion card (daughter card) VPD subsystem manufacturing ID. For consistent results, view as a table and not as individual entries.
1.3.6.1.4.1.2.3.51.2.2.21.4.1.1.33ColumnbladeDaughterVpdCleiread-onlydeprecatedBlade expansion card (daughter card) VPD Common Language Equipment Identifier (CLEI). For consistent results, view as a table and not as individual entries.
1.3.6.1.4.1.2.3.51.2.2.21.4.1.1.34ColumnbladeDaughterVpdHardwareRevisionStringread-onlydeprecatedBlade expansion card (daughter card) VPD hardware revision in string format. For consistent results, view as a table and not as individual entries. If a hardwa…
1.3.6.1.4.1.2.3.51.2.2.21.4.2TablebladeMACAddressVpdTablenot-accessiblemandatoryTable of MAC addresses of the blade and its expansion cards (daughter cards). For consistent results, view as a table and not as individual entries.
1.3.6.1.4.1.2.3.51.2.2.21.4.2.1RowbladeMACAddressVpdEntrynot-accessiblemandatoryBlade MAC address entry. For consistent results, view as a table and not as individual entries.
1.3.6.1.4.1.2.3.51.2.2.21.4.2.1.1ColumnbladeMACAddressVpdIndexread-onlymandatoryBlade index. For consistent results, view as a table and not as individual entries.
1.3.6.1.4.1.2.3.51.2.2.21.4.2.1.2ColumnbladeMACAddress1Vpdread-onlymandatoryBlade MAC address 1. For consistent results, view as a table and not as individual entries.
1.3.6.1.4.1.2.3.51.2.2.21.4.2.1.3ColumnbladeMACAddress2Vpdread-onlymandatoryBlade MAC address 2. For consistent results, view as a table and not as individual entries.
1.3.6.1.4.1.2.3.51.2.2.21.4.2.1.4ColumnbladeMACAddress3Vpdread-onlymandatoryBlade MAC address 3. For consistent results, view as a table and not as individual entries.
1.3.6.1.4.1.2.3.51.2.2.21.4.2.1.5ColumnbladeMACAddress4Vpdread-onlymandatoryBlade MAC address 4. For consistent results, view as a table and not as individual entries.
1.3.6.1.4.1.2.3.51.2.2.21.4.2.1.6ColumnbladeMACAddress5Vpdread-onlymandatoryBlade MAC address 5. For consistent results, view as a table and not as individual entries.
1.3.6.1.4.1.2.3.51.2.2.21.4.2.1.7ColumnbladeMACAddress6Vpdread-onlymandatoryBlade MAC address 6. For consistent results, view as a table and not as individual entries.
1.3.6.1.4.1.2.3.51.2.2.21.4.2.1.8ColumnbladeMACAddress7Vpdread-onlymandatoryBlade MAC address 7. For consistent results, view as a table and not as individual entries.
1.3.6.1.4.1.2.3.51.2.2.21.4.2.1.9ColumnbladeMACAddress8Vpdread-onlymandatoryBlade MAC address 8. For consistent results, view as a table and not as individual entries.
1.3.6.1.4.1.2.3.51.2.2.21.4.2.1.10ColumnbladeDaughterCard1MACAddress1Vpdread-onlymandatoryBlade expansion card (daughter card) 1 MAC address 1. For consistent results, view as a table and not as individual entries.
1.3.6.1.4.1.2.3.51.2.2.21.4.2.1.11ColumnbladeDaughterCard1MACAddress2Vpdread-onlymandatoryBlade expansion card (daughter card) 1 MAC address 2. For consistent results, view as a table and not as individual entries.
1.3.6.1.4.1.2.3.51.2.2.21.4.2.1.12ColumnbladeDaughterCard1MACAddress3Vpdread-onlymandatoryBlade expansion card (daughter card) 1 MAC address 3. For consistent results, view as a table and not as individual entries.
1.3.6.1.4.1.2.3.51.2.2.21.4.2.1.13ColumnbladeDaughterCard1MACAddress4Vpdread-onlymandatoryBlade expansion card (daughter card) 1 MAC address 4. For consistent results, view as a table and not as individual entries.
1.3.6.1.4.1.2.3.51.2.2.21.4.2.1.14ColumnbladeDaughterCard1MACAddress5Vpdread-onlymandatoryBlade expansion card (daughter card) 1 MAC address 5. For consistent results, view as a table and not as individual entries.
1.3.6.1.4.1.2.3.51.2.2.21.4.2.1.15ColumnbladeDaughterCard1MACAddress6Vpdread-onlymandatoryBlade expansion card (daughter card) 1 MAC address 6. For consistent results, view as a table and not as individual entries.
1.3.6.1.4.1.2.3.51.2.2.21.4.2.1.16ColumnbladeDaughterCard1MACAddress7Vpdread-onlymandatoryBlade expansion card (daughter card) 1 MAC address 7. For consistent results, view as a table and not as individual entries.
1.3.6.1.4.1.2.3.51.2.2.21.4.2.1.17ColumnbladeDaughterCard1MACAddress8Vpdread-onlymandatoryBlade expansion card (daughter card) 1 MAC address 8. For consistent results, view as a table and not as individual entries.
1.3.6.1.4.1.2.3.51.2.2.21.4.2.1.18ColumnbladeDaughterCard2MACAddress1Vpdread-onlymandatoryBlade expansion card (daughter card) 2 MAC address 1. For consistent results, view as a table and not as individual entries.
1.3.6.1.4.1.2.3.51.2.2.21.4.2.1.19ColumnbladeDaughterCard2MACAddress2Vpdread-onlymandatoryBlade expansion card (daughter card) 2 MAC address 2. For consistent results, view as a table and not as individual entries.
1.3.6.1.4.1.2.3.51.2.2.21.4.2.1.20ColumnbladeDaughterCard2MACAddress3Vpdread-onlymandatoryBlade expansion card (daughter card) 2 MAC address 3. For consistent results, view as a table and not as individual entries.
1.3.6.1.4.1.2.3.51.2.2.21.4.2.1.21ColumnbladeDaughterCard2MACAddress4Vpdread-onlymandatoryBlade expansion card (daughter card) 2 MAC address 4. For consistent results, view as a table and not as individual entries.
1.3.6.1.4.1.2.3.51.2.2.21.4.2.1.22ColumnbladeDaughterCard2MACAddress5Vpdread-onlymandatoryBlade expansion card (daughter card) 2 MAC address 5. For consistent results, view as a table and not as individual entries.
1.3.6.1.4.1.2.3.51.2.2.21.4.2.1.23ColumnbladeDaughterCard2MACAddress6Vpdread-onlymandatoryBlade expansion card (daughter card) 2 MAC address 6. For consistent results, view as a table and not as individual entries.
1.3.6.1.4.1.2.3.51.2.2.21.4.2.1.24ColumnbladeDaughterCard2MACAddress7Vpdread-onlymandatoryBlade expansion card (daughter card) 2 MAC address 7. For consistent results, view as a table and not as individual entries.
1.3.6.1.4.1.2.3.51.2.2.21.4.2.1.25ColumnbladeDaughterCard2MACAddress8Vpdread-onlymandatoryBlade expansion card (daughter card) 2 MAC address 8. For consistent results, view as a table and not as individual entries.
1.3.6.1.4.1.2.3.51.2.2.21.4.2.1.26ColumnbladeDaughterCard3MACAddress1Vpdread-onlymandatoryBlade expansion card (daughter card) 3 MAC address 1. For consistent results, view as a table and not as individual entries.
1.3.6.1.4.1.2.3.51.2.2.21.4.2.1.27ColumnbladeDaughterCard3MACAddress2Vpdread-onlymandatoryBlade expansion card (daughter card) 3 MAC address 2. For consistent results, view as a table and not as individual entries.
1.3.6.1.4.1.2.3.51.2.2.21.4.2.1.28ColumnbladeDaughterCard3MACAddress3Vpdread-onlymandatoryBlade expansion card (daughter card) 3 MAC address 3. For consistent results, view as a table and not as individual entries.
1.3.6.1.4.1.2.3.51.2.2.21.4.2.1.29ColumnbladeDaughterCard3MACAddress4Vpdread-onlymandatoryBlade expansion card (daughter card) 3 MAC address 4. For consistent results, view as a table and not as individual entries.
1.3.6.1.4.1.2.3.51.2.2.21.4.2.1.30ColumnbladeDaughterCard3MACAddress5Vpdread-onlymandatoryBlade expansion card (daughter card) 3 MAC address 5. For consistent results, view as a table and not as individual entries.
1.3.6.1.4.1.2.3.51.2.2.21.4.2.1.31ColumnbladeDaughterCard3MACAddress6Vpdread-onlymandatoryBlade expansion card (daughter card) 3 MAC address 6. For consistent results, view as a table and not as individual entries.
1.3.6.1.4.1.2.3.51.2.2.21.4.2.1.32ColumnbladeDaughterCard3MACAddress7Vpdread-onlymandatoryBlade expansion card (daughter card) 3 MAC address 7. For consistent results, view as a table and not as individual entries.
1.3.6.1.4.1.2.3.51.2.2.21.4.2.1.33ColumnbladeDaughterCard3MACAddress8Vpdread-onlymandatoryBlade expansion card (daughter card) 3 MAC address 8. For consistent results, view as a table and not as individual entries.
1.3.6.1.4.1.2.3.51.2.2.21.4.2.1.34ColumnbladeDaughterCard4MACAddress1Vpdread-onlymandatoryBlade expansion card (daughter card) 4 MAC address 1. For consistent results, view as a table and not as individual entries.
1.3.6.1.4.1.2.3.51.2.2.21.4.2.1.35ColumnbladeDaughterCard4MACAddress2Vpdread-onlymandatoryBlade expansion card (daughter card) 4 MAC address 2. For consistent results, view as a table and not as individual entries.
1.3.6.1.4.1.2.3.51.2.2.21.4.2.1.36ColumnbladeDaughterCard4MACAddress3Vpdread-onlymandatoryBlade expansion card (daughter card) 4 MAC address 3. For consistent results, view as a table and not as individual entries.
1.3.6.1.4.1.2.3.51.2.2.21.4.2.1.37ColumnbladeDaughterCard4MACAddress4Vpdread-onlymandatoryBlade expansion card (daughter card) 4 MAC address 4. For consistent results, view as a table and not as individual entries.
1.3.6.1.4.1.2.3.51.2.2.21.4.2.1.38ColumnbladeDaughterCard4MACAddress5Vpdread-onlymandatoryBlade expansion card (daughter card) 4 MAC address 5. For consistent results, view as a table and not as individual entries.
1.3.6.1.4.1.2.3.51.2.2.21.4.2.1.39ColumnbladeDaughterCard4MACAddress6Vpdread-onlymandatoryBlade expansion card (daughter card) 4 MAC address 6. For consistent results, view as a table and not as individual entries.
1.3.6.1.4.1.2.3.51.2.2.21.4.2.1.40ColumnbladeDaughterCard4MACAddress7Vpdread-onlymandatoryBlade expansion card (daughter card) 4 MAC address 7. For consistent results, view as a table and not as individual entries.
1.3.6.1.4.1.2.3.51.2.2.21.4.2.1.41ColumnbladeDaughterCard4MACAddress8Vpdread-onlymandatoryBlade expansion card (daughter card) 4 MAC address 8. For consistent results, view as a table and not as individual entries.
1.3.6.1.4.1.2.3.51.2.2.21.4.2.1.42ColumnbladeDaughterCard5MACAddress1Vpdread-onlymandatoryBlade expansion card (daughter card) 5 MAC address 1. For consistent results, view as a table and not as individual entries.
1.3.6.1.4.1.2.3.51.2.2.21.4.2.1.43ColumnbladeDaughterCard5MACAddress2Vpdread-onlymandatoryBlade expansion card (daughter card) 5 MAC address 2. For consistent results, view as a table and not as individual entries.
1.3.6.1.4.1.2.3.51.2.2.21.4.2.1.44ColumnbladeDaughterCard5MACAddress3Vpdread-onlymandatoryBlade expansion card (daughter card) 5 MAC address 3. For consistent results, view as a table and not as individual entries.
1.3.6.1.4.1.2.3.51.2.2.21.4.2.1.45ColumnbladeDaughterCard5MACAddress4Vpdread-onlymandatoryBlade expansion card (daughter card) 5 MAC address 4. For consistent results, view as a table and not as individual entries.
1.3.6.1.4.1.2.3.51.2.2.21.4.2.1.46ColumnbladeDaughterCard5MACAddress5Vpdread-onlymandatoryBlade expansion card (daughter card) 5 MAC address 5. For consistent results, view as a table and not as individual entries.
1.3.6.1.4.1.2.3.51.2.2.21.4.2.1.47ColumnbladeDaughterCard5MACAddress6Vpdread-onlymandatoryBlade expansion card (daughter card) 5 MAC address 6. For consistent results, view as a table and not as individual entries.
1.3.6.1.4.1.2.3.51.2.2.21.4.2.1.48ColumnbladeDaughterCard5MACAddress7Vpdread-onlymandatoryBlade expansion card (daughter card) 5 MAC address 7. For consistent results, view as a table and not as individual entries.
1.3.6.1.4.1.2.3.51.2.2.21.4.2.1.49ColumnbladeDaughterCard5MACAddress8Vpdread-onlymandatoryBlade expansion card (daughter card) 5 MAC address 8. For consistent results, view as a table and not as individual entries.
1.3.6.1.4.1.2.3.51.2.2.21.4.2.1.100ColumnbladeHSDaughterCard1MACAddress1Vpdread-onlymandatoryBlade high speed expansion card (daughter card) 1 MAC address 1. For consistent results, view as a table and not as individual entries.
1.3.6.1.4.1.2.3.51.2.2.21.4.2.1.101ColumnbladeHSDaughterCard1MACAddress2Vpdread-onlymandatoryBlade high speed expansion card (daughter card) 1 MAC address 2. For consistent results, view as a table and not as individual entries.
1.3.6.1.4.1.2.3.51.2.2.21.4.2.1.102ColumnbladeHSDaughterCard1MACAddress3Vpdread-onlymandatoryBlade high speed expansion card (daughter card) 1 MAC address 3. For consistent results, view as a table and not as individual entries.
1.3.6.1.4.1.2.3.51.2.2.21.4.2.1.103ColumnbladeHSDaughterCard1MACAddress4Vpdread-onlymandatoryBlade high speed expansion card (daughter card) 1 MAC address 4. For consistent results, view as a table and not as individual entries.
1.3.6.1.4.1.2.3.51.2.2.21.4.2.1.104ColumnbladeHSDaughterCard1MACAddress5Vpdread-onlymandatoryBlade high speed expansion card (daughter card) 1 MAC address 5. For consistent results, view as a table and not as individual entries.
1.3.6.1.4.1.2.3.51.2.2.21.4.2.1.105ColumnbladeHSDaughterCard1MACAddress6Vpdread-onlymandatoryBlade high speed expansion card (daughter card) 1 MAC address 6. For consistent results, view as a table and not as individual entries.
1.3.6.1.4.1.2.3.51.2.2.21.4.2.1.106ColumnbladeHSDaughterCard1MACAddress7Vpdread-onlymandatoryBlade high speed expansion card (daughter card) 1 MAC address 7. For consistent results, view as a table and not as individual entries.
1.3.6.1.4.1.2.3.51.2.2.21.4.2.1.107ColumnbladeHSDaughterCard1MACAddress8Vpdread-onlymandatoryBlade high speed expansion card (daughter card) 1 MAC address 8. For consistent results, view as a table and not as individual entries.
1.3.6.1.4.1.2.3.51.2.2.21.4.2.1.164ColumnbladeSideCardMACAddress1Vpdread-onlymandatoryBlade side card MAC address 1. For consistent results, view as a table and not as individual entries.
1.3.6.1.4.1.2.3.51.2.2.21.4.2.1.165ColumnbladeSideCardMACAddress2Vpdread-onlymandatoryBlade side card MAC address 2. For consistent results, view as a table and not as individual entries.
1.3.6.1.4.1.2.3.51.2.2.21.4.2.1.166ColumnbladeSideCardMACAddress3Vpdread-onlymandatoryBlade side card MAC address 3. For consistent results, view as a table and not as individual entries.
1.3.6.1.4.1.2.3.51.2.2.21.4.2.1.167ColumnbladeSideCardMACAddress4Vpdread-onlymandatoryBlade side card MAC address 4. For consistent results, view as a table and not as individual entries.
1.3.6.1.4.1.2.3.51.2.2.21.4.2.1.168ColumnbladeSideCardMACAddress5Vpdread-onlymandatoryBlade side card MAC address 5. For consistent results, view as a table and not as individual entries.
1.3.6.1.4.1.2.3.51.2.2.21.4.2.1.169ColumnbladeSideCardMACAddress6Vpdread-onlymandatoryBlade side card MAC address 6. For consistent results, view as a table and not as individual entries.
1.3.6.1.4.1.2.3.51.2.2.21.4.2.1.170ColumnbladeSideCardMACAddress7Vpdread-onlymandatoryBlade side card MAC address 7. For consistent results, view as a table and not as individual entries.
1.3.6.1.4.1.2.3.51.2.2.21.4.2.1.171ColumnbladeSideCardMACAddress8Vpdread-onlymandatoryBlade side card MAC address 8. For consistent results, view as a table and not as individual entries.
1.3.6.1.4.1.2.3.51.2.2.21.4.5TablebladeExpCardVpdTablenot-accessibledeprecatedTable of VPD information for the blade expansion card components. For consistent results, view as a table and not as individual entries.
1.3.6.1.4.1.2.3.51.2.2.21.4.5.1RowbladeExpCardVpdEntrynot-accessibledeprecatedBlade expansion card VPD entry. For consistent results, view as a table and not as individual entries.
1.3.6.1.4.1.2.3.51.2.2.21.4.5.1.1ColumnbladeExpCardVpdIndexread-onlydeprecatedBlade expansion card VPD index. For consistent results, view as a table and not as individual entries.
1.3.6.1.4.1.2.3.51.2.2.21.4.5.1.2ColumnbladeExpCardVpdBayNumberread-onlydeprecatedBlade expansion card VPD Bay number. For consistent results, view as a table and not as individual entries.
1.3.6.1.4.1.2.3.51.2.2.21.4.5.1.3ColumnbladeExpCardVpdManufacturingIdread-onlydeprecatedBlade expansion card VPD manufacturing ID. For consistent results, view as a table and not as individual entries.
1.3.6.1.4.1.2.3.51.2.2.21.4.5.1.4ColumnbladeExpCardVpdFruNumberread-onlydeprecatedBlade expansion card VPD FRU number. For consistent results, view as a table and not as individual entries.
1.3.6.1.4.1.2.3.51.2.2.21.4.5.1.5ColumnbladeExpCardVpdHardwareRevisionread-onlydeprecatedBlade expansion card VPD hardware revision. For consistent results, view as a table and not as individual entries. If a hardware revision is programmed in the …
1.3.6.1.4.1.2.3.51.2.2.21.4.5.1.6ColumnbladeExpCardVpdSerialNumberread-onlydeprecatedBlade expansion card VPD serial number. For consistent results, view as a table and not as individual entries.
1.3.6.1.4.1.2.3.51.2.2.21.4.5.1.7ColumnbladeExpCardVpdMachineTyperead-onlydeprecatedBlade expansion card VPD machine type. For consistent results, view as a table and not as individual entries.
1.3.6.1.4.1.2.3.51.2.2.21.4.5.1.8ColumnbladeExpCardVpdUuidread-onlydeprecatedBlade expansion card VPD UUID. For consistent results, view as a table and not as individual entries.
1.3.6.1.4.1.2.3.51.2.2.21.4.5.1.9ColumnbladeExpCardVpdManufDateread-onlydeprecatedBlade expansion card VPD Manufacture Date. For consistent results, view as a table and not as individual entries.
1.3.6.1.4.1.2.3.51.2.2.21.4.5.1.10ColumnbladeExpCardVpdPartNumberread-onlydeprecatedBlade expansion card VPD Part number. For consistent results, view as a table and not as individual entries.
1.3.6.1.4.1.2.3.51.2.2.21.4.5.1.11ColumnbladeExpCardVpdFruSerialread-onlydeprecatedBlade expansion card VPD FRU serial number. For consistent results, view as a table and not as individual entries.
1.3.6.1.4.1.2.3.51.2.2.21.4.5.1.12ColumnbladeExpCardVpdMachineModelread-onlydeprecatedBlade expansion card VPD machine model. For consistent results, view as a table and not as individual entries.
1.3.6.1.4.1.2.3.51.2.2.21.4.5.1.13ColumnbladeExpCardVpdManufacturingIDNumberread-onlydeprecatedBlade expansion card VPD Manufacturer ID Number. For consistent results, view as a table and not as individual entries.
1.3.6.1.4.1.2.3.51.2.2.21.4.5.1.14ColumnbladeExpCardVpdProductIdread-onlydeprecatedBlade expansion card VPD Product ID. For consistent results, view as a table and not as individual entries.
1.3.6.1.4.1.2.3.51.2.2.21.4.5.1.15ColumnbladeExpCardVpdSubManufacturerIdread-onlydeprecatedBlade expansion card VPD subsystem manufacturer ID. For consistent results, view as a table and not as individual entries.
1.3.6.1.4.1.2.3.51.2.2.21.4.5.1.16ColumnbladeExpCardVpdCleiread-onlydeprecatedBlade expansion card VPD Common Language Equipment Identifier (CLEI). For consistent results, view as a table and not as individual entries.
1.3.6.1.4.1.2.3.51.2.2.21.4.5.1.19ColumnbladeExpCardVpdBladeBayNumberread-onlydeprecatedBlade bay number of the blade expansion card. For consistent results, view as a table and not as individual entries.
1.3.6.1.4.1.2.3.51.2.2.21.4.5.1.21ColumnbladeExpCardVpdCardTypeInforead-onlydeprecatedBlade expansion card (daughter card) VPD type code that describes the expansion card. For consistent results, view as a table and not as individual entries. NO…
1.3.6.1.4.1.2.3.51.2.2.21.4.5.1.22ColumnbladeExpCardVpdHighSpeedread-onlydeprecatedBlade expansion card (daughter card) VPD high speed that indicates whether the expansion card is high speed or not. For consistent results, view as a table and…
1.3.6.1.4.1.2.3.51.2.2.21.4.5.1.23ColumnbladeExpCardVpdHardwareRevisionStringread-onlydeprecatedBlade expansion card VPD hardware revision in string format. For consistent results, view as a table and not as individual entries. If a hardware revision is p…
1.3.6.1.4.1.2.3.51.2.2.21.4.7TablebladeAndExpCardWwnGuidVpdTablenot-accessibledeprecatedTable of World Wide Names (WWN), Global Unique IDs (GUID) and Serial Attach SCSI IDs (SAS) of the blade server and its expansion cards (daughter cards). For co…
1.3.6.1.4.1.2.3.51.2.2.21.4.7.1RowbladeAndExpCardWwnGuidVpdEntrynot-accessibledeprecatedBlade WWN/GUID entries. For consistent results, view as a table and not as individual entries.
1.3.6.1.4.1.2.3.51.2.2.21.4.7.1.1ColumnbladeAndExpCardWwnGuidVpdIndexread-onlydeprecatedBlade or expansion card index. For consistent results, view as a table and not as individual entries.
1.3.6.1.4.1.2.3.51.2.2.21.4.7.1.2ColumnbladeAndExpCardWwnGuidVpdBayNumberread-onlydeprecatedBlade or expansion card VPD bay number. For consistent results, view as a table and not as individual entries.
1.3.6.1.4.1.2.3.51.2.2.21.4.7.1.3ColumnbladeAndExpCardWwnGuidVpdNameread-onlydeprecatedThe name of the blade or expansion card. For consistent results, view as a table and not as individual entries.
1.3.6.1.4.1.2.3.51.2.2.21.4.7.1.4ColumnbladeAndExpCardWwnGuidVpdBladeBayNumberread-onlydeprecatedFor expansion cards, it's the blade bay number of the blade expansion card. For blades, it's the bay number of the blade. For consistent results, view as a tab…
1.3.6.1.4.1.2.3.51.2.2.21.4.7.1.5ColumnbladeAndExpCardWwnGuidVpdTyperead-onlydeprecatedBlade or expansion card WWN/GUID/SAS Type. For consistent results, view as a table and not as individual entries.
1.3.6.1.4.1.2.3.51.2.2.21.4.7.1.6ColumnbladeAndExpCardWwnGuidVpd1read-onlydeprecatedBlade or expansion card WWN/GUID 1. For consistent results, view as a table and not as individual entries.
1.3.6.1.4.1.2.3.51.2.2.21.4.7.1.7ColumnbladeAndExpCardWwnGuidVpd2read-onlydeprecatedBlade or expansion card WWN/GUID 2. For consistent results, view as a table and not as individual entries.
1.3.6.1.4.1.2.3.51.2.2.21.4.7.1.8ColumnbladeAndExpCardWwnGuidVpd3read-onlydeprecatedBlade or expansion card WWN/GUID 3. For consistent results, view as a table and not as individual entries.
1.3.6.1.4.1.2.3.51.2.2.21.4.7.1.9ColumnbladeAndExpCardWwnGuidVpd4read-onlydeprecatedBlade or expansion card WWN/GUID 4. For consistent results, view as a table and not as individual entries.
1.3.6.1.4.1.2.3.51.2.2.21.4.7.1.10ColumnbladeAndExpCardWwnGuidVpd5read-onlydeprecatedBlade or expansion card WWN/GUID 5. For consistent results, view as a table and not as individual entries.
1.3.6.1.4.1.2.3.51.2.2.21.4.7.1.11ColumnbladeAndExpCardWwnGuidVpd6read-onlydeprecatedBlade or expansion card WWN/GUID 6. For consistent results, view as a table and not as individual entries.
1.3.6.1.4.1.2.3.51.2.2.21.4.7.1.12ColumnbladeAndExpCardWwnGuidVpd7read-onlydeprecatedBlade or expansion card WWN/GUID 7. For consistent results, view as a table and not as individual entries.
1.3.6.1.4.1.2.3.51.2.2.21.4.7.1.13ColumnbladeAndExpCardWwnGuidVpd8read-onlydeprecatedBlade or expansion card WWN/GUID 8. For consistent results, view as a table and not as individual entries.
1.3.6.1.4.1.2.3.51.2.2.21.4.8TablebladeManagementCardVpdTablenot-accessibledeprecatedTable of VPD information for the blade management card component. For consistent results, view as a table and not as individual entries.
1.3.6.1.4.1.2.3.51.2.2.21.4.8.1RowbladeManagementCardVpdEntrynot-accessibledeprecatedBlade management card VPD entry. For consistent results, view as a table and not as individual entries.
1.3.6.1.4.1.2.3.51.2.2.21.4.8.1.1ColumnbladeManagementCardVpdIndexread-onlydeprecatedBlade management card VPD index. For consistent results, view as a table and not as individual entries.
1.3.6.1.4.1.2.3.51.2.2.21.4.8.1.2ColumnbladeManagementCardVpdBayNumberread-onlydeprecatedBlade management card VPD Bay number. For consistent results, view as a table and not as individual entries.
1.3.6.1.4.1.2.3.51.2.2.21.4.8.1.3ColumnbladeManagementCardVpdManufacturingIdread-onlydeprecatedBlade management card VPD manufacturing ID. For consistent results, view as a table and not as individual entries.
1.3.6.1.4.1.2.3.51.2.2.21.4.8.1.4ColumnbladeManagementCardVpdFruNumberread-onlydeprecatedBlade management card VPD FRU number. For consistent results, view as a table and not as individual entries.
1.3.6.1.4.1.2.3.51.2.2.21.4.8.1.5ColumnbladeManagementCardVpdHardwareRevisionread-onlydeprecatedBlade management card VPD hardware revision. For consistent results, view as a table and not as individual entries. If a hardware revision is programmed in the…
1.3.6.1.4.1.2.3.51.2.2.21.4.8.1.6ColumnbladeManagementCardVpdSerialNumberread-onlydeprecatedBlade management card VPD serial number. For consistent results, view as a table and not as individual entries.
1.3.6.1.4.1.2.3.51.2.2.21.4.8.1.7ColumnbladeManagementCardVpdMachineTyperead-onlydeprecatedBlade management card VPD machine type. For consistent results, view as a table and not as individual entries.
1.3.6.1.4.1.2.3.51.2.2.21.4.8.1.8ColumnbladeManagementCardVpdUuidread-onlydeprecatedBlade management card VPD UUID. For consistent results, view as a table and not as individual entries.
1.3.6.1.4.1.2.3.51.2.2.21.4.8.1.9ColumnbladeManagementCardVpdManufDateread-onlydeprecatedBlade management card VPD Manufacture Date. For consistent results, view as a table and not as individual entries.
1.3.6.1.4.1.2.3.51.2.2.21.4.8.1.10ColumnbladeManagementCardVpdPartNumberread-onlydeprecatedBlade management card VPD Part number. For consistent results, view as a table and not as individual entries.
1.3.6.1.4.1.2.3.51.2.2.21.4.8.1.11ColumnbladeManagementCardVpdFruSerialread-onlydeprecatedBlade management card VPD FRU serial number. For consistent results, view as a table and not as individual entries.
1.3.6.1.4.1.2.3.51.2.2.21.4.8.1.12ColumnbladeManagementCardVpdMachineModelread-onlydeprecatedBlade management card VPD machine model. For consistent results, view as a table and not as individual entries.
1.3.6.1.4.1.2.3.51.2.2.21.4.8.1.13ColumnbladeManagementCardVpdManufacturingIDNumberread-onlydeprecatedBlade management card VPD manufacturer ID. For consistent results, view as a table and not as individual entries.
1.3.6.1.4.1.2.3.51.2.2.21.4.8.1.14ColumnbladeManagementCardVpdProductIdread-onlydeprecatedBlade management card VPD Product ID. For consistent results, view as a table and not as individual entries.
1.3.6.1.4.1.2.3.51.2.2.21.4.8.1.15ColumnbladeManagementCardVpdSubManufacturerIdread-onlydeprecatedBlade management card VPD subsystem manufacturer ID. For consistent results, view as a table and not as individual entries.
1.3.6.1.4.1.2.3.51.2.2.21.4.8.1.16ColumnbladeManagementCardVpdCleiread-onlydeprecatedBlade management card VPD Common Language Equipment Identifier (CLEI). For consistent results, view as a table and not as individual entries.
1.3.6.1.4.1.2.3.51.2.2.21.4.8.1.17ColumnbladeManagementCardVpdHardwareRevisionStringread-onlydeprecatedBlade management card VPD hardware revision in string format. For consistent results, view as a table and not as individual entries. If a hardware revision is …
1.3.6.1.4.1.2.3.51.2.2.21.5NodebladeFirmwareVpd
1.3.6.1.4.1.2.3.51.2.2.21.5.1TablebladeBiosVPDTablenot-accessibledeprecatedTable of blade firmware vital product data (VPD) information.
1.3.6.1.4.1.2.3.51.2.2.21.5.1.1RowbladeBiosVPDEntrynot-accessibledeprecatedBlade firmware VPD table entry
1.3.6.1.4.1.2.3.51.2.2.21.5.1.1.1ColumnbladeBiosVpdIndexread-onlydeprecatedBlade firmware VPD table index.
1.3.6.1.4.1.2.3.51.2.2.21.5.1.1.2ColumnbladeBiosVpdIdread-onlydeprecatedThe numeric blade ID.
1.3.6.1.4.1.2.3.51.2.2.21.5.1.1.3ColumnbladeBiosVpdExistsread-onlydeprecatedIndicates whether the server blade specified exists or not.
1.3.6.1.4.1.2.3.51.2.2.21.5.1.1.4ColumnbladeBiosVpdPowerStateread-onlydeprecatedIndicates the power state of the blade specified.
1.3.6.1.4.1.2.3.51.2.2.21.5.1.1.5ColumnbladeBiosVpdNameread-onlydeprecatedThe name of the blade as a null terminated string.
1.3.6.1.4.1.2.3.51.2.2.21.5.1.1.6ColumnbladeBiosVpdBuildIdread-onlydeprecatedThe build ID for the blade firmware.
1.3.6.1.4.1.2.3.51.2.2.21.5.1.1.7ColumnbladeBiosVpdRevisionread-onlydeprecatedThe revision of the blade firmware.
1.3.6.1.4.1.2.3.51.2.2.21.5.1.1.8ColumnbladeBiosVpdDateread-onlydeprecatedThe date of the blade firmware.
1.3.6.1.4.1.2.3.51.2.2.21.5.1.1.9ColumnbladeBiosVpdLevelStatusread-onlydeprecatedThe level status of the blade bios firmware build ID. It has three possible values as Different (mismatch firmware build ID), Match (the same firmware build ID…
1.3.6.1.4.1.2.3.51.2.2.21.5.2TablebladeDiagsVPDTablenot-accessibledeprecatedTable of blade firmware vital product data (VPD) information.
1.3.6.1.4.1.2.3.51.2.2.21.5.2.1RowbladeDiagsVPDEntrynot-accessibledeprecatedBlade firmware VPD table entry
1.3.6.1.4.1.2.3.51.2.2.21.5.2.1.1ColumnbladeDiagsVpdIndexread-onlydeprecatedBlade firmware VPD table index.
1.3.6.1.4.1.2.3.51.2.2.21.5.2.1.2ColumnbladeDiagsVpdIdread-onlydeprecatedThe numeric blade ID.
1.3.6.1.4.1.2.3.51.2.2.21.5.2.1.3ColumnbladeDiagsVpdExistsread-onlydeprecatedIndicates whether the server blade specified exists or not.
1.3.6.1.4.1.2.3.51.2.2.21.5.2.1.4ColumnbladeDiagsVpdPowerStateread-onlydeprecatedIndicates the power state of the blade specified.
1.3.6.1.4.1.2.3.51.2.2.21.5.2.1.5ColumnbladeDiagsVpdNameread-onlydeprecatedThe name of the blade as a null terminated string.
1.3.6.1.4.1.2.3.51.2.2.21.5.2.1.6ColumnbladeDiagsVpdBuildIdread-onlydeprecatedThe build ID for the blade firmware.
1.3.6.1.4.1.2.3.51.2.2.21.5.2.1.7ColumnbladeDiagsVpdRevisionread-onlydeprecatedThe revision of the blade firmware.
1.3.6.1.4.1.2.3.51.2.2.21.5.2.1.8ColumnbladeDiagsVpdDateread-onlydeprecatedThe date of the blade firmware.
1.3.6.1.4.1.2.3.51.2.2.21.5.2.1.9ColumnbladeDiagsVpdLevelStatusread-onlydeprecatedThe level status of the blade diagnostics firmware build ID. It has three possible values as Different (mismatch firmware build ID), Match (the same firmware b…
1.3.6.1.4.1.2.3.51.2.2.21.5.3TablebladeSysMgmtProcVPDTablenot-accessibledeprecatedTable of blade firmware vital product data (VPD) information.
1.3.6.1.4.1.2.3.51.2.2.21.5.3.1RowbladeSysMgmtProcVPDEntrynot-accessibledeprecatedBlade firmware VPD table entry
1.3.6.1.4.1.2.3.51.2.2.21.5.3.1.1ColumnbladeSysMgmtProcVpdIndexread-onlydeprecatedBlade firmware VPD table index.
1.3.6.1.4.1.2.3.51.2.2.21.5.3.1.2ColumnbladeSysMgmtProcVpdIdread-onlydeprecatedThe numeric blade ID.
1.3.6.1.4.1.2.3.51.2.2.21.5.3.1.3ColumnbladeSysMgmtProcVpdExistsread-onlydeprecatedIndicates whether the server blade specified exists or not.
1.3.6.1.4.1.2.3.51.2.2.21.5.3.1.4ColumnbladeSysMgmtProcVpdPowerStateread-onlydeprecatedIndicates the power state of the blade specified.
1.3.6.1.4.1.2.3.51.2.2.21.5.3.1.5ColumnbladeSysMgmtProcVpdNameread-onlydeprecatedThe name of the blade as a null terminated string.
1.3.6.1.4.1.2.3.51.2.2.21.5.3.1.6ColumnbladeSysMgmtProcVpdBuildIdread-onlydeprecatedThe build ID for the blade firmware.
1.3.6.1.4.1.2.3.51.2.2.21.5.3.1.7ColumnbladeSysMgmtProcVpdRevisionread-onlydeprecatedThe revision of the blade firmware.
1.3.6.1.4.1.2.3.51.2.2.21.5.3.1.8ColumnbladeSysMgmtProcVpdLevelStatusread-onlydeprecatedThe level status of the blade system management processor firmware build ID. It has three possible values as Different (mismatch firmware build ID), Match (the…
1.3.6.1.4.1.2.3.51.2.2.21.6NodesmHardwareVpd
1.3.6.1.4.1.2.3.51.2.2.21.6.1TablesmHardwareVpdTablenot-accessibledeprecatedTable of the switch module hardware components. For consistent results, view as a table and not as individual entries.
1.3.6.1.4.1.2.3.51.2.2.21.6.1.1RowsmHardwareVpdEntrynot-accessibledeprecatedSwitch module hardware VPD entry. For consistent results, view as a table and not as individual entries.
1.3.6.1.4.1.2.3.51.2.2.21.6.1.1.1ColumnsmHardwareVpdIndexread-onlydeprecatedSwitch module hardware VPD index. For consistent results, view as a table and not as individual entries.
1.3.6.1.4.1.2.3.51.2.2.21.6.1.1.2ColumnsmHardwareVpdBayNumberread-onlydeprecatedSwitch module hardware VPD Bay number. For consistent results, view as a table and not as individual entries.
1.3.6.1.4.1.2.3.51.2.2.21.6.1.1.3ColumnsmHardwareVpdManufacturingIdread-onlydeprecatedSwitch module hardware VPD manufacturing ID. For consistent results, view as a table and not as individual entries.
1.3.6.1.4.1.2.3.51.2.2.21.6.1.1.4ColumnsmHardwareVpdFruNumberread-onlydeprecatedSwitch module hardware VPD FRU number. For consistent results, view as a table and not as individual entries.
1.3.6.1.4.1.2.3.51.2.2.21.6.1.1.5ColumnsmHardwareVpdHardwareRevisionread-onlydeprecatedSwitch module hardware VPD hardware revision. For consistent results, view as a table and not as individual entries. If a hardware revision is programmed in th…
1.3.6.1.4.1.2.3.51.2.2.21.6.1.1.8ColumnsmHardwareVpdUuidread-onlydeprecatedSwitch module hardware VPD UUID. For consistent results, view as a table and not as individual entries.
1.3.6.1.4.1.2.3.51.2.2.21.6.1.1.9ColumnsmHardwareVpdManufDateread-onlydeprecatedSwitch module hardware VPD manufacture date. For consistent results, view as a table and not as individual entries.
1.3.6.1.4.1.2.3.51.2.2.21.6.1.1.10ColumnsmHardwareVpdPartNumberread-onlydeprecatedSwitch module hardware VPD Part Number. For consistent results, view as a table and not as individual entries.
1.3.6.1.4.1.2.3.51.2.2.21.6.1.1.11ColumnsmHardwareVpdFruSerialread-onlydeprecatedSwitch module hardware VPD FRU Serial. For consistent results, view as a table and not as individual entries.
1.3.6.1.4.1.2.3.51.2.2.21.6.1.1.12ColumnsmHardwareVpdManufacturingIDNumberread-onlydeprecatedSwitch module hardware VPD manufacturer ID. For consistent results, view as a table and not as individual entries.
1.3.6.1.4.1.2.3.51.2.2.21.6.1.1.13ColumnsmHardwareVpdProductIdread-onlydeprecatedSwitch module hardware VPD product ID. For consistent results, view as a table and not as individual entries.
1.3.6.1.4.1.2.3.51.2.2.21.6.1.1.14ColumnsmHardwareVpdSubManufacturerIdread-onlydeprecatedSwitch module hardware VPD subsystem manufacturer ID. For consistent results, view as a table and not as individual entries.
1.3.6.1.4.1.2.3.51.2.2.21.6.1.1.15ColumnsmHardwareVpdCleiread-onlydeprecatedSwitch module hardware VPD Common Language Equipment Identifier (CLEI). For consistent results, view as a table and not as individual entries.
1.3.6.1.4.1.2.3.51.2.2.21.6.1.1.16ColumnsmHardwareVpdWwnGuidread-onlydeprecatedSwitch module hardware VPD World Wide Name or Global Unique ID. For consistent results, view as a table and not as individual entries.
1.3.6.1.4.1.2.3.51.2.2.21.6.1.1.17ColumnsmHardwareVpdWwnGuidTyperead-onlydeprecatedThe WWN/GUID/SAS entry is actually World Wide Name, Global Unique ID or Serial Attach SCSI ID. For consistent results, view as a table and not as individual en…
1.3.6.1.4.1.2.3.51.2.2.21.6.1.1.18ColumnsmHardwareVpdWidthread-onlydeprecatedThe width of the switch module hardware. For consistent results, view as a table and not as individual entries.
1.3.6.1.4.1.2.3.51.2.2.21.6.1.1.20ColumnsmHardwareVpdHardwareRevisionStringread-onlydeprecatedSwitch module hardware VPD hardware revision in string format. For consistent results, view as a table and not as individual entries. If a hardware revision is…
1.3.6.1.4.1.2.3.51.2.2.21.7NodesmFirmwareVpd
1.3.6.1.4.1.2.3.51.2.2.21.7.1TablesmMainAppVpdTablenot-accessibledeprecatedSwitch module main application VPD information table.
1.3.6.1.4.1.2.3.51.2.2.21.7.1.1RowsmMainAppVpdEntrynot-accessibledeprecatedSwitch module main application VPD table entry
1.3.6.1.4.1.2.3.51.2.2.21.7.1.1.1ColumnsmMainAppVpdIndexread-onlydeprecatedSwitch module main application VPD entry index.
1.3.6.1.4.1.2.3.51.2.2.21.7.1.1.2ColumnsmMainAppVpdIdread-onlydeprecatedThe switch module numeric identifier.
1.3.6.1.4.1.2.3.51.2.2.21.7.1.1.3ColumnsmMainAppVpdExistsread-onlydeprecatedIndicates whether the switch module specified exists or not.
1.3.6.1.4.1.2.3.51.2.2.21.7.1.1.4ColumnsmMainAppVpdSwitchTyperead-onlydeprecatedIndicates the type of switch module installed.
1.3.6.1.4.1.2.3.51.2.2.21.7.1.1.5ColumnsmMainApp1VpdBuildIdread-onlydeprecatedSwitch module firmware build id.
1.3.6.1.4.1.2.3.51.2.2.21.7.1.1.6ColumnsmMainApp1VpdBuildDateread-onlydeprecatedSwitch module firmware build date.
1.3.6.1.4.1.2.3.51.2.2.21.7.1.1.7ColumnsmMainApp1VpdRevisionNumberread-onlydeprecatedSwitch module firmware revision number.
1.3.6.1.4.1.2.3.51.2.2.21.7.1.1.8ColumnsmMainApp2VpdBuildIdread-onlydeprecatedSwitch module firmware build id.
1.3.6.1.4.1.2.3.51.2.2.21.7.1.1.9ColumnsmMainApp2VpdBuildDateread-onlydeprecatedSwitch module firmware build date.
1.3.6.1.4.1.2.3.51.2.2.21.7.1.1.10ColumnsmMainApp2VpdRevisionNumberread-onlydeprecatedSwitch module firmware revision number.
1.3.6.1.4.1.2.3.51.2.2.21.7.1.1.11ColumnsmMainApp3VpdBuildIdread-onlydeprecatedI/O Module firmware build id.
1.3.6.1.4.1.2.3.51.2.2.21.7.1.1.12ColumnsmMainApp3VpdBuildDateread-onlydeprecatedI/O Module firmware build date.
1.3.6.1.4.1.2.3.51.2.2.21.7.1.1.13ColumnsmMainApp3VpdRevisionNumberread-onlydeprecatedI/O Module firmware revision number.
1.3.6.1.4.1.2.3.51.2.2.21.7.1.1.20ColumnsmMainAppVpdSwitchSubTyperead-onlydeprecatedIndicates the subtype of switch module installed.
1.3.6.1.4.1.2.3.51.2.2.21.7.2TablesmBootRomVpdTablenot-accessibledeprecatedSwitch module boot ROM VPD information table.
1.3.6.1.4.1.2.3.51.2.2.21.7.2.1RowsmBootRomVpdEntrynot-accessibledeprecatedSwitch module boot ROM VPD table entry
1.3.6.1.4.1.2.3.51.2.2.21.7.2.1.1ColumnsmBootRomVpdIndexread-onlydeprecatedSwitch module boot ROM VPD entry index.
1.3.6.1.4.1.2.3.51.2.2.21.7.2.1.2ColumnsmBootRomVpdIdread-onlydeprecatedThe switch module numeric identifier.
1.3.6.1.4.1.2.3.51.2.2.21.7.2.1.3ColumnsmBootRomVpdExistsread-onlydeprecatedIndicates whether the switch module specified exists or not.
1.3.6.1.4.1.2.3.51.2.2.21.7.2.1.4ColumnsmBootRomVpdSwitchTyperead-onlydeprecatedIndicates the type of switch module installed.
1.3.6.1.4.1.2.3.51.2.2.21.7.2.1.5ColumnsmBootRomVpdBuildIdread-onlydeprecatedSwitch module firmware build ID.
1.3.6.1.4.1.2.3.51.2.2.21.7.2.1.6ColumnsmBootRomVpdBuildDateread-onlydeprecatedSwitch module firmware build date.
1.3.6.1.4.1.2.3.51.2.2.21.7.2.1.7ColumnsmBootRomVpdRevisionNumberread-onlydeprecatedSwitch module firmware revision number.
1.3.6.1.4.1.2.3.51.2.2.21.7.2.1.8ColumnsmBootRomVpdSwitchSubTyperead-onlydeprecatedIndicates the subtype of switch module installed.
1.3.6.1.4.1.2.3.51.2.2.21.8NodepmHardwareVpd
1.3.6.1.4.1.2.3.51.2.2.21.8.1TablepmHardwareVpdTablenot-accessibledeprecatedTable of the power module hardware components. For consistent results, view as a table and not as individual entries.
1.3.6.1.4.1.2.3.51.2.2.21.8.1.1RowpmHardwareVpdEntrynot-accessibledeprecatedPower module hardware VPD entry. For consistent results, view as a table and not as individual entries.
1.3.6.1.4.1.2.3.51.2.2.21.8.1.1.1ColumnpmHardwareVpdIndexread-onlydeprecatedPower module hardware VPD index. For consistent results, view as a table and not as individual entries.
1.3.6.1.4.1.2.3.51.2.2.21.8.1.1.2ColumnpmHardwareVpdBayNumberread-onlydeprecatedPower module hardware VPD Bay number. For consistent results, view as a table and not as individual entries.
1.3.6.1.4.1.2.3.51.2.2.21.8.1.1.3ColumnpmHardwareVpdManufacturingIdread-onlydeprecatedPower module hardware VPD manufacturing ID. For consistent results, view as a table and not as individual entries.
1.3.6.1.4.1.2.3.51.2.2.21.8.1.1.4ColumnpmHardwareVpdFruNumberread-onlydeprecatedPower module hardware VPD FRU number. For consistent results, view as a table and not as individual entries.
1.3.6.1.4.1.2.3.51.2.2.21.8.1.1.5ColumnpmHardwareVpdHardwareRevisionread-onlydeprecatedPower module hardware VPD hardware revision. For consistent results, view as a table and not as individual entries. If a hardware revision is programmed in the…
1.3.6.1.4.1.2.3.51.2.2.21.8.1.1.8ColumnpmHardwareVpdUuidread-onlydeprecatedPower module hardware VPD UUID. For consistent results, view as a table and not as individual entries.
1.3.6.1.4.1.2.3.51.2.2.21.8.1.1.9ColumnpmHardwareVpdManufDateread-onlydeprecatedPower module hardware VPD Manufacture Date. For consistent results, view as a table and not as individual entries.
1.3.6.1.4.1.2.3.51.2.2.21.8.1.1.10ColumnpmHardwareVpdPartNumberread-onlydeprecatedPower module hardware VPD Part Number. For consistent results, view as a table and not as individual entries.
1.3.6.1.4.1.2.3.51.2.2.21.8.1.1.11ColumnpmHardwareVpdFruSerialread-onlydeprecatedPower module hardware VPD FRU Serial. For consistent results, view as a table and not as individual entries.
1.3.6.1.4.1.2.3.51.2.2.21.8.1.1.12ColumnpmHardwareVpdManufacturingIDNumberread-onlydeprecatedPower module hardware VPD manufacturer ID. For consistent results, view as a table and not as individual entries.
1.3.6.1.4.1.2.3.51.2.2.21.8.1.1.13ColumnpmHardwareVpdProductIdread-onlydeprecatedPower module hardware VPD product ID. For consistent results, view as a table and not as individual entries.
1.3.6.1.4.1.2.3.51.2.2.21.8.1.1.14ColumnpmHardwareVpdSubManufacturerIdread-onlydeprecatedPower module hardware VPD subsystem manufacturer ID. For consistent results, view as a table and not as individual entries.
1.3.6.1.4.1.2.3.51.2.2.21.8.1.1.15ColumnpmHardwareVpdCleiread-onlydeprecatedPower module hardware VPD Common Language Equipment Identifier (CLEI). For consistent results, view as a table and not as individual entries.
1.3.6.1.4.1.2.3.51.2.2.21.8.1.1.16ColumnpmHardwareVpdHardwareRevisionStringread-onlydeprecatedPower module hardware VPD hardware revision in string format. For consistent results, view as a table and not as individual entries. If a hardware revision is …
1.3.6.1.4.1.2.3.51.2.2.21.9NoderearLEDCardHardwareVpd
1.3.6.1.4.1.2.3.51.2.2.21.9.3ScalarrearLEDCardHardwareVpdManufacturingIdread-onlydeprecatedRear LED card hardware VPD manufacturing ID. For consistent results, view as a table and not as individual entries.
1.3.6.1.4.1.2.3.51.2.2.21.9.4ScalarrearLEDCardHardwareVpdFruNumberread-onlydeprecatedRear LED card hardware VPD FRU number. For consistent results, view as a table and not as individual entries.
1.3.6.1.4.1.2.3.51.2.2.21.9.5ScalarrearLEDCardHardwareVpdHardwareRevisionread-onlydeprecatedRear LED card hardware VPD hardware revision. For consistent results, view as a table and not as individual entries. If a hardware revision is programmed in th…
1.3.6.1.4.1.2.3.51.2.2.21.9.8ScalarrearLEDCardHardwareVpdUuidread-onlydeprecatedRear LED card hardware VPD UUID. For consistent results, view as a table and not as individual entries.
1.3.6.1.4.1.2.3.51.2.2.21.9.9ScalarrearLEDCardHardwareVpdManufacturingIDNumberread-onlydeprecatedRear LED card hardware VPD manufacturer ID. For consistent results, view as a table and not as individual entries.
1.3.6.1.4.1.2.3.51.2.2.21.9.10ScalarrearLEDCardHardwareVpdProductIdread-onlydeprecatedRear LED card hardware VPD product ID. For consistent results, view as a table and not as individual entries.
1.3.6.1.4.1.2.3.51.2.2.21.9.11ScalarrearLEDCardHardwareVpdSubManufacturerIdread-onlydeprecatedRear LED card hardware VPD subsystem manufacturer ID. For consistent results, view as a table and not as individual entries.
1.3.6.1.4.1.2.3.51.2.2.21.9.12ScalarrearLEDCardHardwareVpdCleiread-onlydeprecatedRear LED card hardware VPD Common Language Equipment Identifier (CLEI). For consistent results, view as a table and not as individual entries.
1.3.6.1.4.1.2.3.51.2.2.21.9.17ScalarrearLEDCardHardwareVpdHardwareRevisionStringread-onlydeprecatedRear LED card hardware VPD hardware revision in string format. For consistent results, view as a table and not as individual entries. If a hardware revision is…
1.3.6.1.4.1.2.3.51.2.2.21.9.18ScalarrearLEDCardHardwareVpdManufDateread-onlydeprecatedRear LED card hardware VPD Manufacture Date.
1.3.6.1.4.1.2.3.51.2.2.21.9.19ScalarrearLEDCardHardwareVpdPartNumberread-onlydeprecatedRear LED card hardware VPD Part Number.
1.3.6.1.4.1.2.3.51.2.2.21.9.20ScalarrearLEDCardHardwareVpdFruSerialread-onlydeprecatedRear LED card hardware VPD FRU Serial.
1.3.6.1.4.1.2.3.51.2.2.21.12NodechassisFanFirmwareVpd
1.3.6.1.4.1.2.3.51.2.2.21.12.1TablechassisFanControllerVPDTablenot-accessibledeprecatedTable of chassis fan controller firmware vital product data (VPD) information.
1.3.6.1.4.1.2.3.51.2.2.21.12.1.1RowchassisFanControllerVPDEntrynot-accessibledeprecatedChassis fan controller firmware VPD table entry
1.3.6.1.4.1.2.3.51.2.2.21.12.1.1.1ColumnchassisFanControllerVpdIndexread-onlydeprecatedChassis fan controller firmware VPD table index.
1.3.6.1.4.1.2.3.51.2.2.21.12.1.1.2ColumnchassisFanControllerVpdIdread-onlydeprecatedThe numeric chassis fan ID.
1.3.6.1.4.1.2.3.51.2.2.21.12.1.1.3ColumnchassisFanControllerVpdExistsread-onlydeprecatedIndicates whether the chassis fan specified exists or not.
1.3.6.1.4.1.2.3.51.2.2.21.12.1.1.7ColumnchassisFanControllerVpdRevisionread-onlydeprecatedThe revision of the chassis fan controller firmware.
1.3.6.1.4.1.2.3.51.2.2.21.13NodechassisFanHardwareVpd
1.3.6.1.4.1.2.3.51.2.2.21.13.1TablechassisFanHardwareVpdTablenot-accessibledeprecatedTable of the chassis fan hardware components.
1.3.6.1.4.1.2.3.51.2.2.21.13.1.1RowchassisFanHardwareVpdEntrynot-accessibledeprecatedChassis fan hardware VPD entry.
1.3.6.1.4.1.2.3.51.2.2.21.13.1.1.1ColumnchassisFanHardwareVpdIndexread-onlydeprecatedChassis fan hardware VPD index.
1.3.6.1.4.1.2.3.51.2.2.21.13.1.1.2ColumnchassisFanHardwareVpdBayNumberread-onlydeprecatedChassis fan hardware VPD Bay number.
1.3.6.1.4.1.2.3.51.2.2.21.13.1.1.3ColumnchassisFanHardwareVpdManufacturingIdread-onlydeprecatedChassis fan hardware VPD manufacturing ID.
1.3.6.1.4.1.2.3.51.2.2.21.13.1.1.4ColumnchassisFanHardwareVpdFruNumberread-onlydeprecatedChassis fan hardware VPD FRU number.
1.3.6.1.4.1.2.3.51.2.2.21.13.1.1.5ColumnchassisFanHardwareVpdHardwareRevisionread-onlydeprecatedChassis fan hardware VPD hardware revision.
1.3.6.1.4.1.2.3.51.2.2.21.13.1.1.8ColumnchassisFanHardwareVpdUuidread-onlydeprecatedChassis fan hardware VPD UUID.
1.3.6.1.4.1.2.3.51.2.2.21.13.1.1.9ColumnchassisFanHardwareVpdManufDateread-onlydeprecatedChassis fan hardware VPD manufacture Date.
1.3.6.1.4.1.2.3.51.2.2.21.13.1.1.10ColumnchassisFanHardwareVpdPartNumberread-onlydeprecatedChassis fan hardware VPD Part Number.
1.3.6.1.4.1.2.3.51.2.2.21.13.1.1.11ColumnchassisFanHardwareVpdFruSerialread-onlydeprecatedChassis fan hardware VPD FRU serial number.
1.3.6.1.4.1.2.3.51.2.2.21.13.1.1.12ColumnchassisFanHardwareVpdManufacturingIDNumberread-onlydeprecatedChassis fan hardware VPD manufacturer ID.
1.3.6.1.4.1.2.3.51.2.2.21.13.1.1.13ColumnchassisFanHardwareVpdProductIdread-onlydeprecatedChassis fan hardware VPD product ID.
1.3.6.1.4.1.2.3.51.2.2.21.13.1.1.14ColumnchassisFanHardwareVpdSubManufacturerIdread-onlydeprecatedChassis fan hardware VPD subsystem manufacturer ID.
1.3.6.1.4.1.2.3.51.2.2.21.13.1.1.15ColumnchassisFanHardwareVpdCleiread-onlydeprecatedChassis fan hardware VPD Common Language Equipment Identifier (CLEI).
1.3.6.1.4.1.2.3.51.2.2.21.13.1.1.16ColumnchassisFanHardwareVpdHardwareRevisionStringread-onlydeprecatedChassis fan hardware VPD hardware revision in string format.
1.3.6.1.4.1.2.3.51.2.2.21.14NodepmFirmwareVpd
1.3.6.1.4.1.2.3.51.2.2.21.14.1TablepmControllerVPDTablenot-accessibledeprecatedTable of Power Module controller firmware vital product data (VPD) information.
1.3.6.1.4.1.2.3.51.2.2.21.14.1.1RowpmControllerVPDEntrynot-accessibledeprecatedPower Module controller firmware VPD table entry
1.3.6.1.4.1.2.3.51.2.2.21.14.1.1.1ColumnpmControllerVpdIndexread-onlydeprecatedPower Module controller firmware VPD table index.
1.3.6.1.4.1.2.3.51.2.2.21.14.1.1.2ColumnpmControllerVpdIdread-onlydeprecatedThe numeric Power Module ID.
1.3.6.1.4.1.2.3.51.2.2.21.14.1.1.3ColumnpmControllerVpdExistsread-onlydeprecatedIndicates whether the Power Module specified exists or not.
1.3.6.1.4.1.2.3.51.2.2.21.14.1.1.7ColumnpmControllerVpdRevisionread-onlydeprecatedThe revision of the Power Module controller firmware.
1.3.6.1.4.1.2.3.51.2.2.21.22TableinventoryManagementActivityVpdTablenot-accessiblemandatoryTable of system component hardware VPD activity log. For consistent results, view as a table and not as individual entries.
1.3.6.1.4.1.2.3.51.2.2.21.22.1RowinventoryManagementActivityVpdEntrynot-accessiblemandatorySystem component hardware VPD activity log entry. For consistent results, view as a table and not as individual entries.
1.3.6.1.4.1.2.3.51.2.2.21.22.1.1ColumncomponentLevelActivityVpdIndexread-onlymandatorySystem component level VPD activity log index. For consistent results, view as a table and not as individual entries.
1.3.6.1.4.1.2.3.51.2.2.21.22.1.2ColumncomponentLevelActivityVpdFruNumberread-onlymandatorySystem component level VPD activity log FRU number. For consistent results, view as a table and not as individual entries.
1.3.6.1.4.1.2.3.51.2.2.21.22.1.3ColumncomponentLevelActivityVpdSerialNumberread-onlymandatorySystem component level VPD activity log serial number. For consistent results, view as a table and not as individual entries.
1.3.6.1.4.1.2.3.51.2.2.21.22.1.4ColumncomponentLevelActivityVpdManufacturingIdread-onlymandatorySystem component level VPD activity log manufacturing ID. For consistent results, view as a table and not as individual entries.
1.3.6.1.4.1.2.3.51.2.2.21.22.1.5ColumncomponentLevelActivityVpdBayNumberread-onlydeprecatedSystem component level VPD activity log Bay number. For consistent results, view as a table and not as individual entries.
1.3.6.1.4.1.2.3.51.2.2.21.22.1.9ColumncomponentLevelActivityVpdActionread-onlymandatorySystem component level VPD activity log action (added/removed). For consistent results, view as a table and not as individual entries.
1.3.6.1.4.1.2.3.51.2.2.21.22.1.10ColumncomponentLevelActivityVpdTimestampread-onlymandatorySystem component level VPD activity log timestamp. For consistent results, view as a table and not as individual entries.
1.3.6.1.4.1.2.3.51.2.2.21.22.1.12ColumncomponentLevelActivityVpdModuleNameread-onlymandatoryThe module name which this row is associated with. For consistent results, view as a table and not as individual entries.
1.3.6.1.4.1.2.3.51.2.2.21.22.1.15ColumncomponentLevelActivityVpdTopologyPathread-onlymandatoryThe chassis and each installed component is represented by a hardware topology tree, where each node in the tree represents a component. As an example, the roo…
1.3.6.1.4.1.2.3.51.2.2.21.23NodereloadVpdData
1.3.6.1.4.1.2.3.51.2.2.21.23.1ScalarreloadAllVpdDataread-writemandatoryReload all VPD data (firmware, hardware, MAC address, WWN/GUID and other Unique ID). NOTE: The value returned for the GET command is meaningless.
1.3.6.1.4.1.2.3.51.2.2.21.23.2ScalarreloadFwVpdDataread-writemandatoryReload firmware VPD data. NOTE: The value returned for the GET command is meaningless.
1.3.6.1.4.1.2.3.51.2.2.21.23.3ScalarreloadHwVpdDataread-writemandatoryReload hardware VPD data. NOTE: The value returned for the GET command is meaningless.
1.3.6.1.4.1.2.3.51.2.2.21.23.4ScalarreloadMACAddressread-writemandatoryReload blade MAC addresses. NOTE: The value returned for the GET command is meaningless.
1.3.6.1.4.1.2.3.51.2.2.21.23.5ScalarreloadWwnGuidVpdDataread-writemandatoryReload blade and I/O module WWN/GUID and other VPD data. NOTE: The value returned for the GET command is meaningless.
1.3.6.1.4.1.2.3.51.2.2.22NodeairFilter
1.3.6.1.4.1.2.3.51.2.2.22.1NodepassiveAirFilter
1.3.6.1.4.1.2.3.51.2.2.22.1.1ScalarpassiveAirFilterStatusread-writemandatoryDisable/Enable/Reset the passive air filter. When enabled, sending an enable or reset will reset the replace date.
1.3.6.1.4.1.2.3.51.2.2.22.1.2ScalarpassiveAirFilterMonthFreqread-writemandatoryThe chassis environment. 1 month indicates high dust, 3 months indicates moderate dust and, 6 months indicates low dust.
1.3.6.1.4.1.2.3.51.2.2.22.1.3ScalarpassiveAirFilterReplaceDateread-onlymandatoryThe scheduled replacement date of the air filter.
1.3.6.1.4.1.2.3.51.2.2.23NodecomponentInformation
1.3.6.1.4.1.2.3.51.2.2.23.1NodecomponentInventory
1.3.6.1.4.1.2.3.51.2.2.23.1.1TablecomponentInventoryTablenot-accessiblemandatoryTable of component inventory information. Not all components will provide every object defined in the ComponentInventoryEntry. Also, if a component does not ha…
1.3.6.1.4.1.2.3.51.2.2.23.1.1.1RowcomponentInventoryEntrynot-accessiblemandatoryComponent inventory information.
1.3.6.1.4.1.2.3.51.2.2.23.1.1.1.1ColumncomponentInventoryTopologyPathread-onlymandatoryThe unique identifier for a row in this table. The chassis and each installed component is represented by a hardware topology tree, where each node in the tree…
1.3.6.1.4.1.2.3.51.2.2.23.1.1.1.2ColumncomponentInventoryInstanceread-onlymandatoryThe slot number or instance of a particular component. Typically, if the component plugs into the chassis, this represents the slot number. However, some compo…
1.3.6.1.4.1.2.3.51.2.2.23.1.1.1.3ColumncomponentInventoryDescriptionread-onlymandatoryA short text string describing the particular component. If a text string is not available, a value of 'Not available' is presented. For more detail, also refe…
1.3.6.1.4.1.2.3.51.2.2.23.1.1.1.4ColumncomponentInventoryMachineTypeModelread-onlymandatoryThe machine type and model number of this component. Typically, the format is XXXXYYY, where XXXX reprsents the machine type and YYY represents the model numbe…
1.3.6.1.4.1.2.3.51.2.2.23.1.1.1.5ColumncomponentInventoryMachineSerialread-onlymandatoryThe machine serial number of this component.
1.3.6.1.4.1.2.3.51.2.2.23.1.1.1.6ColumncomponentInventoryAssetIDread-onlymandatoryThe asset identifier of this component, typically set by some other authority than the manufacturer.
1.3.6.1.4.1.2.3.51.2.2.23.1.1.1.7ColumncomponentInventoryPartNumberread-onlymandatoryThe part number of this component.
1.3.6.1.4.1.2.3.51.2.2.23.1.1.1.8ColumncomponentInventoryFRUNumberread-onlymandatoryThe Field Replaceable Unit (FRU) number of this component.
1.3.6.1.4.1.2.3.51.2.2.23.1.1.1.9ColumncomponentInventoryFRUSerialNumberread-onlymandatoryThe Field Replaceable Unit (FRU) serial number of this component.
1.3.6.1.4.1.2.3.51.2.2.23.1.1.1.10ColumncomponentInventoryManufactureread-onlymandatoryThe text description of the manufacturer of this component.
1.3.6.1.4.1.2.3.51.2.2.23.1.1.1.11ColumncomponentInventoryHardwareRevisionread-onlymandatoryThe hardware revision number of the this component.
1.3.6.1.4.1.2.3.51.2.2.23.1.1.1.12ColumncomponentInventoryManufactureDateread-onlymandatoryThe date when the manufacturer created this component. The format is XXYY, where XX is the week number of the year 20YY.
1.3.6.1.4.1.2.3.51.2.2.23.1.1.1.13ColumncomponentInventoryUUIDread-onlymandatoryThe Universally Unique IDentifier (UUID) of this component, represented as a 16 byte hex number.
1.3.6.1.4.1.2.3.51.2.2.23.1.1.1.14ColumncomponentInventoryProductIDread-onlymandatoryThe product identifier of the component assigned by the manufacturer.
1.3.6.1.4.1.2.3.51.2.2.23.1.1.1.15ColumncomponentInventorySubManufactureIDread-onlymandatoryThe text sub-description of the manufacturer of this component, often used to identify a supplier for a component which has multiple suppliers.
1.3.6.1.4.1.2.3.51.2.2.23.1.1.1.16ColumncomponentInventoryCLEIread-onlymandatoryThe Common Language Equipment Identifier (CLEI) of this component.
1.3.6.1.4.1.2.3.51.2.2.23.1.1.1.17ColumncomponentInventoryAssetTagread-onlymandatoryThe asset tag of this component.
1.3.6.1.4.1.2.3.51.2.2.23.1.1.1.18ColumncomponentInventorySpeedread-onlymandatoryA speed designation for the component, for example, processor speed.
1.3.6.1.4.1.2.3.51.2.2.23.1.1.1.19ColumncomponentInventoryIdentifierread-onlymandatoryA unique identifier assigned by the manufacturer to the component, for example, a processor ID.
1.3.6.1.4.1.2.3.51.2.2.23.1.1.1.20ColumncomponentInventorySizeread-onlymandatoryA size designation for the component, for example, a memory DIMM size or hard drive capacity.
1.3.6.1.4.1.2.3.51.2.2.23.1.1.1.21ColumncomponentInventoryMemoryTyperead-onlymandatoryThe architecture specification of a memory device.
1.3.6.1.4.1.2.3.51.2.2.23.1.1.1.22ColumncomponentInventoryProductNameread-onlymandatoryThe product name assigned by the manufacturer for this component. For more detail, also refer to the componentInventoryDescription object.
1.3.6.1.4.1.2.3.51.2.2.23.1.1.1.23ColumncomponentInventoryProductVersionread-onlymandatoryThe product version assigned by the manufacturer for this component.
1.3.6.1.4.1.2.3.51.2.2.23.1.1.1.24ColumncomponentInventoryProcessorTyperead-onlymandatoryThe type designation for processor components.
1.3.6.1.4.1.2.3.51.2.2.23.1.1.1.25ColumncomponentInventoryProcessorFamilyread-onlymandatoryThe family designation for processor components.
1.3.6.1.4.1.2.3.51.2.2.23.1.1.1.26ColumncomponentInventoryProcessorCoresread-onlymandatoryThe number of cores present on a processor component.
1.3.6.1.4.1.2.3.51.2.2.23.1.1.1.27ColumncomponentInventoryProcessorThreadsread-onlymandatoryThe number of threads present on a processor component.
1.3.6.1.4.1.2.3.51.2.2.23.1.1.1.28ColumncomponentInventoryProcessorL1DCacheread-onlymandatoryThe level 1 data cache size of a processor component.
1.3.6.1.4.1.2.3.51.2.2.23.1.1.1.29ColumncomponentInventoryProcessorL1ICacheread-onlymandatoryThe level 1 instruction cache size of a processor component.
1.3.6.1.4.1.2.3.51.2.2.23.1.1.1.30ColumncomponentInventoryProcessorL2Cacheread-onlymandatoryThe level 2 cache size of a processor component.
1.3.6.1.4.1.2.3.51.2.2.23.1.1.1.31ColumncomponentInventoryProcessorL3Cacheread-onlymandatoryThe level 3 cache size of a processor component.
1.3.6.1.4.1.2.3.51.2.2.23.1.1.1.32ColumncomponentInventoryProcessorVoltageread-onlymandatoryThe voltage rating for a processor component.
1.3.6.1.4.1.2.3.51.2.2.23.1.1.1.33ColumncomponentInventoryProcessorExtClockread-onlymandatoryThe external clock speed of a processor component.
1.3.6.1.4.1.2.3.51.2.2.23.1.1.1.34ColumncomponentInventoryProcessorDataWidthread-onlymandatoryThe maximum data bus width capability of a processor component, expressed typically in bits.
1.3.6.1.4.1.2.3.51.2.2.23.1.1.1.35ColumncomponentInventoryManufactureIDNumread-onlymandatoryThe identification number assigned for the component by the manufacturer.
1.3.6.1.4.1.2.3.51.2.2.23.1.1.1.41ColumncomponentInventoryGlobalIDread-onlymandatoryThe global identifier (GLID) of this component. This ID is a unique identifier for the CMM chassis (midplane), set by the manufacturer. This ID and the associa…
1.3.6.1.4.1.2.3.51.2.2.23.1.2ScalarcomponentInventoryTableCacheTimeoutread-onlymandatoryThe timeout value (in seconds) of the cached data for the table, componentInventoryTable. This value is static (constant) and cannot be set.
1.3.6.1.4.1.2.3.51.2.2.23.2NodecomponentFirmware
1.3.6.1.4.1.2.3.51.2.2.23.2.1TablecomponentFirmwareTablenot-accessiblemandatoryTable of component firmware information. Not all components will provide every object defined in the ComponentFirmwareEntry.
1.3.6.1.4.1.2.3.51.2.2.23.2.1.1RowcomponentFirmwareEntrynot-accessiblemandatoryComponent firmware information.
1.3.6.1.4.1.2.3.51.2.2.23.2.1.1.1ColumncomponentFirmwareTopologyPathread-onlymandatoryThe unique identifier for a component in this table. The chassis and each installed component is represented by a hardware topology tree, where each node in th…
1.3.6.1.4.1.2.3.51.2.2.23.2.1.1.2ColumncomponentFirmwareIndexread-onlymandatoryEach component may have one or more types of firmware associated with it, and this index object identifies the particular instance.
1.3.6.1.4.1.2.3.51.2.2.23.2.1.1.3ColumncomponentFirmwareComponentInstanceread-onlymandatoryThe slot number or instance of a particular component. Typically, if the component plugs into the chassis, this represents the slot number. However, some compo…
1.3.6.1.4.1.2.3.51.2.2.23.2.1.1.4ColumncomponentFirmwareComponentDescriptionread-onlymandatoryA short text string describing the particular component. For the MM and blades, this name will be the configured name or its serial number if no user configure…
1.3.6.1.4.1.2.3.51.2.2.23.2.1.1.5ColumncomponentFirmwareTyperead-onlymandatoryA text description of the type of firmware load.
1.3.6.1.4.1.2.3.51.2.2.23.2.1.1.6ColumncomponentFirmwareBuildIDread-onlymandatoryA text description of the build identifier for this firmware load.
1.3.6.1.4.1.2.3.51.2.2.23.2.1.1.7ColumncomponentFirmwareReleaseDateread-onlymandatoryA text description of the release date for this firmware load.
1.3.6.1.4.1.2.3.51.2.2.23.2.1.1.8ColumncomponentFirmwareFilenameread-onlymandatoryA text description of the filename of this firmware load.
1.3.6.1.4.1.2.3.51.2.2.23.2.1.1.9ColumncomponentFirmwareRevisionread-onlymandatoryA text description of the revision level of this firmware load.
1.3.6.1.4.1.2.3.51.2.2.23.2.1.1.10ColumncomponentFirmwareRevisionMajorread-onlymandatoryA numeric identifier of the revision major number for this firmware load.
1.3.6.1.4.1.2.3.51.2.2.23.2.1.1.11ColumncomponentFirmwareRevisionMinorread-onlymandatoryA numeric identifier of the revision minor number for this firmware load.
1.3.6.1.4.1.2.3.51.2.2.23.2.1.1.12ColumncomponentFirmwareLevelStatusread-onlymandatoryThe level status of the firmware build ID. It has three possible values as Different (mismatch firmware build ID), Match (the same firmware build ID), Unique (…
1.3.6.1.4.1.2.3.51.2.2.23.2.1.1.13ColumncomponentFirmwarePendingBuildIDread-onlymandatoryA text description of the build identifier for this pending firmware load.
1.3.6.1.4.1.2.3.51.2.2.23.2.1.1.14ColumncomponentFirmwarePendingReleaseDateread-onlymandatoryA text description of the release date for this pending firmware load.
1.3.6.1.4.1.2.3.51.2.2.23.2.1.1.15ColumncomponentFirmwarePendingRevisionread-onlymandatoryA text description of the revision level of this pending firmware load.
1.3.6.1.4.1.2.3.51.2.2.23.2.1.1.16ColumncomponentFirmwareReleaseLevelread-onlymandatoryA text description of the firmware release level this firmware load.
1.3.6.1.4.1.2.3.51.2.2.23.2.1.1.17ColumncomponentFirmwareImageStatusread-onlymandatoryThis object indicates whether this firmware image is the active (1) firmware,otherwise this firmware image is inactive (0).
1.3.6.1.4.1.2.3.51.2.2.23.2.1.1.18ColumncomponentFirmwareRoleread-onlymandatoryA text description with the firmware image information.
1.3.6.1.4.1.2.3.51.2.2.23.2.1.1.20ColumncomponentFirmwareTypeIDread-onlymandatoryIndicates the type of firmware load with a numeric identifier.
1.3.6.1.4.1.2.3.51.2.2.23.2.2ScalarcomponentFirmwareTableCacheTimeoutread-onlymandatoryThe timeout value (in seconds) of the cached data for the table, componentFirmwareTable. This value is static (constant) and cannot be set.
1.3.6.1.4.1.2.3.51.2.2.23.2.7TablenodeFirmwareAnalysisTablenot-accessiblemandatoryTable of firmware levels of installed nodes. This information is grouped by Machine Type/Model and includes two or more nodes with the same Type/Model. This in…
1.3.6.1.4.1.2.3.51.2.2.23.2.7.1RownodeFirmwareAnalysisEntrynot-accessiblemandatoryNode firmware analysis information.
1.3.6.1.4.1.2.3.51.2.2.23.2.7.1.1ColumnnodeFirmwareAnalysisIndexread-onlymandatoryThe index for the node firmware levels.
1.3.6.1.4.1.2.3.51.2.2.23.2.7.1.2ColumnnodeFirmwareAnalysisMachineTypeModelread-onlymandatoryThe machine type or model of node firmware.
1.3.6.1.4.1.2.3.51.2.2.23.2.7.1.3ColumnnodeFirmwareAnalysisFirmwareTyperead-onlymandatoryThe firmware type.
1.3.6.1.4.1.2.3.51.2.2.23.2.7.1.4ColumnnodeFirmwareAnalysisBuildIdread-onlymandatoryThe firmware build id.
1.3.6.1.4.1.2.3.51.2.2.23.2.7.1.5ColumnnodeFirmwareAnalysisReleaseDateread-onlymandatoryThe firmware release date.
1.3.6.1.4.1.2.3.51.2.2.23.2.7.1.6ColumnnodeFirmwareAnalysisRevisionLevelread-onlymandatoryThe firmware revision level.
1.3.6.1.4.1.2.3.51.2.2.23.2.7.1.7ColumnnodeFirmwareAnalysisTopologyread-onlymandatoryThe node topology.
1.3.6.1.4.1.2.3.51.2.2.23.2.7.1.8ColumnnodeFirmwareAnalysisDeviceNameread-onlymandatoryThe node device name.
1.3.6.1.4.1.2.3.51.2.2.23.2.11TablesmFirmwareAnalysisTablenot-accessiblemandatoryTable of firmware levels of installed IOMs. This information is grouped by Product Id and includes two or more IOMs with the same product id. This information …
1.3.6.1.4.1.2.3.51.2.2.23.2.11.1RowsmFirmwareAnalysisEntrynot-accessiblemandatoryIOM firmware analysis information.
1.3.6.1.4.1.2.3.51.2.2.23.2.11.1.1ColumnsmFirmwareAnalysisIndexread-onlymandatoryThe index for the IOM firmware levels.
1.3.6.1.4.1.2.3.51.2.2.23.2.11.1.2ColumnsmFirmwareAnalysisProductIdread-onlymandatoryThe IOM product id.
1.3.6.1.4.1.2.3.51.2.2.23.2.11.1.3ColumnsmFirmwareAnalysisProductNameread-onlymandatoryThe IOM product name.
1.3.6.1.4.1.2.3.51.2.2.23.2.11.1.4ColumnsmFirmwareAnalysisFirmwareTyperead-onlymandatoryThe IOM firmware type.
1.3.6.1.4.1.2.3.51.2.2.23.2.11.1.5ColumnsmFirmwareAnalysisFirmwareVersionread-onlymandatoryThe IOM firmware version.
1.3.6.1.4.1.2.3.51.2.2.23.2.11.1.6ColumnsmFirmwareAnalysisReleaseDateread-onlymandatoryThe IOM release date.
1.3.6.1.4.1.2.3.51.2.2.23.2.11.1.7ColumnsmFirmwareAnalysisTopologyread-onlymandatoryThe IOM topology.
1.3.6.1.4.1.2.3.51.2.2.23.3ScalarcomponentInventoryReadyread-onlymandatoryWhen a blade management controller, switch or the MM is reset, the inventory data is refreshed in the MM database. This includes items like IBM VPD (e.g. - ser…
1.3.6.1.4.1.2.3.51.2.2.23.10TablecomponentDriveTablenot-accessiblemandatoryTable of information indicating presence of a disk drive on a component. The management module does not receive any inventory VPD from the component, so only t…
1.3.6.1.4.1.2.3.51.2.2.23.10.1RowcomponentDriveEntrynot-accessiblemandatoryComponent drive information.
1.3.6.1.4.1.2.3.51.2.2.23.10.1.1ColumncomponentDriveTopologyPathread-onlymandatoryThe unique identifier for a row in this table. The chassis and each installed component is represented by a hardware topology tree, where each node in the tree…
1.3.6.1.4.1.2.3.51.2.2.23.10.1.2ColumncomponentDriveDescriptionread-onlymandatoryA short text string describing the particular drive on the component.
1.3.6.1.4.1.2.3.51.2.2.23.11ScalarcomponentDriveTableCacheTimeoutread-onlymandatoryThe timeout value (in seconds) of the cached data for the table, componentDriveTable. This value is static (constant) and cannot be set.
1.3.6.1.4.1.2.3.51.2.2.30NodelicenseKeyInfo
1.3.6.1.4.1.2.3.51.2.2.30.1TablelicenseKeyInfoTablenot-accessiblemandatoryTable of license key information.
1.3.6.1.4.1.2.3.51.2.2.30.1.1RowlicenseKeyInfoEntrynot-accessiblemandatoryLicense key information entry.
1.3.6.1.4.1.2.3.51.2.2.30.1.1.1ColumnlicenseKeyComponentIndexread-onlymandatoryLicense key component table index.
1.3.6.1.4.1.2.3.51.2.2.30.1.1.2ColumnlicenseKeyIndexread-onlymandatoryThe license key index for the chassis component.
1.3.6.1.4.1.2.3.51.2.2.30.1.1.3ColumnlicenseKeyDescriptionread-onlymandatoryThe description for a license key.
1.3.6.1.4.1.2.3.51.2.2.30.1.1.4ColumnlicenseKeyTimestampread-onlymandatoryThe date and time of this license key.
1.3.6.1.4.1.2.3.51.2.2.30.1.1.5ColumnlicenseKeyLicenseIDread-onlymandatoryThe unique identifier for this license key.
1.3.6.1.4.1.2.3.51.2.2.30.1.1.6ColumnlicenseKeyOtherInforead-onlymandatoryAny other information related to this license key.
1.3.6.1.4.1.2.3.51.2.2.30.1.1.7ColumnlicenseKeyStatusread-onlymandatoryThe current status of this license key.
1.3.6.1.4.1.2.3.51.2.2.30.5TablechassisLicenseKeyTablenot-accessiblemandatoryTable of chassis license key information.
1.3.6.1.4.1.2.3.51.2.2.30.5.1RowchassisLicenseKeyEntrynot-accessiblemandatoryChassis License key information entry.
1.3.6.1.4.1.2.3.51.2.2.30.5.1.1ColumnchassisLicenseKeyIndexread-onlymandatoryThe key index for the chassis license keys.
1.3.6.1.4.1.2.3.51.2.2.30.5.1.2ColumnchassisLicenseKeyFeatureread-onlymandatoryThe name of the Feature for the license key.
1.3.6.1.4.1.2.3.51.2.2.30.5.1.3ColumnchassisLicenseKeyFeatureTyperead-onlymandatoryThe Feature Type Code for the license key.
1.3.6.1.4.1.2.3.51.2.2.30.5.1.4ColumnchassisLicenseKeyDescriptionread-onlymandatoryThe description of the license key.
1.3.6.1.4.1.2.3.51.2.2.30.5.1.5ColumnchassisLicenseKeySystemread-onlymandatorySystem information for the license key.
1.3.6.1.4.1.2.3.51.2.2.30.5.1.6ColumnchassisLicenseKeyLicenseIDread-onlymandatoryIdentification of the license key.
1.3.6.1.4.1.2.3.51.2.2.30.5.1.7ColumnchassisLicenseKeyValidationread-onlymandatoryValidation of the license key.
1.3.6.1.4.1.2.3.51.2.2.30.5.1.8ColumnchassisLicenseKeyStatusread-onlymandatoryThe current status of the license key.
1.3.6.1.4.1.2.3.51.2.2.30.5.1.9ColumnchassisLicenseKeyTimeLimitread-onlymandatoryDate and Time (GMT) when license expires.
1.3.6.1.4.1.2.3.51.2.2.30.5.1.10ColumnchassisLicenseKeyUsageLimitread-onlymandatoryNumber of times remaining for license usage. A negative value indicates that there is no Usage Limit for the license.
1.3.6.1.4.1.2.3.51.2.3NodeerrorLogs
1.3.6.1.4.1.2.3.51.2.3.4NodeeventLog
1.3.6.1.4.1.2.3.51.2.3.4.2TablereadEventLogTablenot-accessiblemandatoryTable of event log entry information.
1.3.6.1.4.1.2.3.51.2.3.4.2.1RowreadEventLogEntrynot-accessiblemandatoryEvent log table entry
1.3.6.1.4.1.2.3.51.2.3.4.2.1.1ColumnreadEventLogIndexread-onlymandatoryThe event log index number.
1.3.6.1.4.1.2.3.51.2.3.4.2.1.2ColumnreadEventLogStringread-onlymandatoryA string of data detailing an event.
1.3.6.1.4.1.2.3.51.2.3.4.3ScalarclearEventLogread-writemandatoryClear the event log. NOTE: Value returned for the GET command is meaningless for this MIB object.
1.3.6.1.4.1.2.3.51.2.3.4.4ScalarmonitorLogStateEventsread-writemandatoryIf disabled, it means the info LED will not turn on when the log gets full and no alerts will be sent out. If enabled, the LED will turn on when the log gets f…
1.3.6.1.4.1.2.3.51.2.3.4.6TablereadEnhancedEventLogTablenot-accessiblemandatoryTable of enhanced event log entry information.
1.3.6.1.4.1.2.3.51.2.3.4.6.1RowreadEnhancedEventLogEntrynot-accessiblemandatoryEnhaced Event log table entry, new entries could be added for new items.
1.3.6.1.4.1.2.3.51.2.3.4.6.1.1ColumnreadEnhancedEventLogNumberread-onlymandatoryThe event log number for the enhanced event log.
1.3.6.1.4.1.2.3.51.2.3.4.6.1.2ColumnreadEnhancedEventLogAttributeread-onlymandatoryA string of data detailing an event log's attribute, such as the Event ID and Call Home Flag. The Event ID is a hexadecimal number representing an specific or …
1.3.6.1.4.1.2.3.51.2.3.4.6.1.3ColumnreadEnhancedEventLogMessageread-onlymandatoryA string of data detailing an event log message.
1.3.6.1.4.1.2.3.51.2.3.4.6.1.4ColumnreadEnhancedEventLogSequenceNumread-onlymandatoryThe sequence number for the enhanced event log. This number is the next sequence number when this event record was create. This number continues to grow, even …
1.3.6.1.4.1.2.3.51.2.3.4.10TablereadAuditLogTablenot-accessiblemandatoryTable of audit log entry information. Audit log includes the logs whose source is 'Audit'
1.3.6.1.4.1.2.3.51.2.3.4.10.1RowreadAuditLogEntrynot-accessiblemandatoryAudit log table entry, new entries could be added for new items.
1.3.6.1.4.1.2.3.51.2.3.4.10.1.1ColumnreadAuditLogNumberread-onlymandatoryThe audit log number.
1.3.6.1.4.1.2.3.51.2.3.4.10.1.2ColumnreadAuditLogAttributeread-onlymandatoryA string of data detailing an audit eventlog's attribute.
1.3.6.1.4.1.2.3.51.2.3.4.10.1.3ColumnreadAuditLogMessageread-onlymandatoryA string of data detailing an audit event log message.
1.3.6.1.4.1.2.3.51.2.3.4.10.1.4ColumnreadAuditLogSequenceNumread-onlymandatoryThe sequence number for the audit event log. This number is the next sequence number when this event record was create. This number continues to grow, even if …
1.3.6.1.4.1.2.3.51.2.3.4.11ScalarclearAuditLogread-writemandatoryClear the audit log. NOTE: Value returned for the GET command is meaningless for this MIB object.
1.3.6.1.4.1.2.3.51.2.3.4.12TablereadSystemLogTablenot-accessiblemandatoryTable of system log entry information. System log includes the logs whose source is other than 'Audit'
1.3.6.1.4.1.2.3.51.2.3.4.12.1RowreadSystemLogEntrynot-accessiblemandatorySystem log table entry, new entries could be added for new items.
1.3.6.1.4.1.2.3.51.2.3.4.12.1.1ColumnreadSystemLogNumberread-onlymandatoryThe system log index number.
1.3.6.1.4.1.2.3.51.2.3.4.12.1.2ColumnreadSystemLogAttributeread-onlymandatoryA string of data detailing an system event log's attribute.
1.3.6.1.4.1.2.3.51.2.3.4.12.1.3ColumnreadSystemLogMessageread-onlymandatoryA string of data detailing an system event log message.
1.3.6.1.4.1.2.3.51.2.3.4.12.1.4ColumnreadSystemLogSequenceNumread-onlymandatoryThe sequence number for the system event log. This number is the next sequence number when this event record was create. This number continues to grow, even if…
1.3.6.1.4.1.2.3.51.2.3.4.13ScalarclearSystemLogread-writemandatoryClear the system log. NOTE: Value returned for the GET command is meaningless for this MIB object.
1.3.6.1.4.1.2.3.51.2.3.4.14TablereadEventLogAuxTablenot-accessiblemandatoryTable of system log entry auxiliary information.
1.3.6.1.4.1.2.3.51.2.3.4.14.1RowreadEventLogAuxEntrynot-accessiblemandatoryEvent log auxiliary table entry, new entries could be added for new items.
1.3.6.1.4.1.2.3.51.2.3.4.14.1.1ColumnreadEventLogAuxNumberread-onlymandatoryThe system log auxiliary index number. To relate this information to the system log, match Sequence number of this entry to the Sequence number of the system l…
1.3.6.1.4.1.2.3.51.2.3.4.14.1.2ColumnreadEventLogAuxSequenceNumread-onlymandatoryThe sequence number for the system event log that contains this Auxiliary information. Value is from 1 through 4294967295 and then wraps.
1.3.6.1.4.1.2.3.51.2.3.4.14.1.3ColumnreadEventLogAuxMessageread-onlymandatoryA string of data detailing the auxiliary information from the log event.
1.3.6.1.4.1.2.3.51.2.4NodeconfigureSP
1.3.6.1.4.1.2.3.51.2.4.1NoderemoteAccessConfig
1.3.6.1.4.1.2.3.51.2.4.1.1NodegeneralRemoteCfg
1.3.6.1.4.1.2.3.51.2.4.1.1.3ScalarremoteAlertRetryDelayread-writemandatoryNumber in seconds to delay between retries if sending a remote alert is unsuccessful.
1.3.6.1.4.1.2.3.51.2.4.1.1.4ScalarremoteAlertRetryCountread-writemandatoryNumber of additional times a remote alert will be retried if not successfully sent. A value of zero indicates no retries will be attempted.
1.3.6.1.4.1.2.3.51.2.4.1.1.7ScalaruserAuthenticationMethodread-writemandatoryUse this field to specify how users attempting to login should be authenticated. There are two methods: Local authentication. Userid and password are verified …
1.3.6.1.4.1.2.3.51.2.4.1.1.9ScalarmaxSessionsPerLDAPUserread-writemandatoryThe maximum number of simultaneous active sessions allowed for each LDAP user. If the value is 0, this option is disabled. The minimum value is 1 and the maxim…
1.3.6.1.4.1.2.3.51.2.4.1.1.10ScalarauthenticationLoggingTimeoutread-writemandatoryUse this option to set how long, in seconds, MM will not log the authentication events for the same user. The default setting is 5 minutes. 0 indicates log all…
1.3.6.1.4.1.2.3.51.2.4.1.1.11ScalartrackingIPread-writemandatoryThis option indicates tracking different IP addresses for the same user is enabled or not. If it is enabled then an access every second from alternating IP add…
1.3.6.1.4.1.2.3.51.2.4.1.1.20NodeaccountSecurityManagement
1.3.6.1.4.1.2.3.51.2.4.1.1.20.1ScalaraccountSecurityLevelread-writemandatoryThe level of security needed for local user login passwords. The legacy level: - no password required - no password expiration - no password re-use restriction…
1.3.6.1.4.1.2.3.51.2.4.1.1.20.2NodecustomSecuritySettings
1.3.6.1.4.1.2.3.51.2.4.1.1.20.2.2ScalarpasswordExpirationPeriodread-writemandatoryThe number of days before login passwords expire. The minimum value is 1 day and the maximum value is 365 days. The default value is 90 days. A value of 0 disa…
1.3.6.1.4.1.2.3.51.2.4.1.1.20.2.3ScalardefaultAdminPasswordExpiredread-writemandatoryIf enabled, the factory default 'USERID' account password must be changed on next login. The default value is disabled.
1.3.6.1.4.1.2.3.51.2.4.1.1.20.2.4ScalarminimumPasswordReuseCycleread-writemandatoryThe number of unique passwords a user must choose before reusing a password. The default value is none.
1.3.6.1.4.1.2.3.51.2.4.1.1.20.2.5ScalarcomplexPasswordRulesread-writemandatoryIf enabled, the minimum complexity rules will be enforced for all local login passwords and 'User login password required' rule will be enabled. The complex ru…
1.3.6.1.4.1.2.3.51.2.4.1.1.20.2.6ScalarminimumDiffCharsPasswordread-writemandatoryThe required minimum number of characters in the new password different from the previous password. The default value is 2. A SET of this object is ignored unt…
1.3.6.1.4.1.2.3.51.2.4.1.1.20.2.7ScalarchangePasswordFirstAccessread-writemandatoryIf enabled, the login user will be forced to change their password on the first access after the account has been established or on the first access after an a…
1.3.6.1.4.1.2.3.51.2.4.1.1.20.2.8ScalarinactivityAlertPeriodread-writemandatoryThe period of time in days before generating an alert for a dormant account. This value applies to all login accounts, including the administrator account. The…
1.3.6.1.4.1.2.3.51.2.4.1.1.20.2.9ScalarinactivityAlertDisablePeriodread-writemandatoryThe period of time in days before generating an alert and disabling a dormant account. This value applies to all login accounts, excluding the administrator ac…
1.3.6.1.4.1.2.3.51.2.4.1.1.20.2.10ScalarlockoutPeriodread-writemandatoryThe period of time in minutes that a user is locked out after the maximum number of login failures was reached. The minimum value is is 1 minute and the maximu…
1.3.6.1.4.1.2.3.51.2.4.1.1.20.2.11ScalarmaxLoginFailuresread-writemandatoryThe maximum number of login failures before a user account is locked. A value of 0 disables this option. The default value is 5.
1.3.6.1.4.1.2.3.51.2.4.1.1.20.2.12ScalarpasswordChangeIntervalread-writemandatoryA minimum period of time that user is not able to change their own password. The range of acceptable values will be from 0 to 1440 (or 60 days). A value of 0 d…
1.3.6.1.4.1.2.3.51.2.4.1.2NodeserialPortCfg
1.3.6.1.4.1.2.3.51.2.4.1.2.1ScalarportBaudread-writemandatoryBaud rate for the serial port.
1.3.6.1.4.1.2.3.51.2.4.1.2.2ScalarportParityread-writemandatoryParity setting for the serial port.
1.3.6.1.4.1.2.3.51.2.4.1.2.3ScalarportStopBitsread-writemandatoryNumber of stop bits for the serial port.
1.3.6.1.4.1.2.3.51.2.4.1.3NoderemoteAlertIds
1.3.6.1.4.1.2.3.51.2.4.1.3.1TableremoteAlertIdsTablenot-accessiblemandatoryTable of remote alert entries. This table lets you configure remote alert recipients. You can define up to 12 unique recipients. NOTE: All selected alert event…
1.3.6.1.4.1.2.3.51.2.4.1.3.1.1RowremoteAlertIdsEntrynot-accessiblemandatoryRemote alert entries.
1.3.6.1.4.1.2.3.51.2.4.1.3.1.1.1ColumnremoteAlertIdEntryIndexread-onlymandatoryIndex for remote alert entry.
1.3.6.1.4.1.2.3.51.2.4.1.3.1.1.2ColumnremoteAlertIdEntryStatusread-writemandatoryRemote alert entry status, invalid means entry not defined yet, disabledAndValid means entry defined but not enabled to send an alert, enabledAndValid means en…
1.3.6.1.4.1.2.3.51.2.4.1.3.1.1.3ColumnremoteAlertIdEntryIpOrHostAddressread-writemandatoryA null terminated string that either contains an IP address of the form '1.2.3.4' or a host name (if DNS is enabled) for the alert entry.
1.3.6.1.4.1.2.3.51.2.4.1.3.1.1.4ColumnremoteAlertIdEntryTextDescriptionread-writemandatoryA null terminated string that contains a text description of this entry.
1.3.6.1.4.1.2.3.51.2.4.1.3.1.1.5ColumnremoteAlertIdEntryNotificationTyperead-writemandatoryRemote alert entry notification method. Types include unknown when the type can't be determined (read-only), snmpOverLan for an SNMP alert over ethernet, and e…
1.3.6.1.4.1.2.3.51.2.4.1.3.1.1.9ColumnremoteAlertIdEmailAddrread-writemandatoryA null terminated string that contains an E-Mail Address. For example, 'xyz@us.ibm.com'. Used only for an E-mail over LAN notification type.
1.3.6.1.4.1.2.3.51.2.4.1.3.1.1.13ColumnremoteAlertIdEntrySelectiveAlertread-writemandatoryRemote alert entry selective alert setting. A value of critOnlyAlerts will only send critical alerts to this remote alert recipient, a value of allAlerts will …
1.3.6.1.4.1.2.3.51.2.4.1.3.30ScalargenerateTestAlertread-writemandatoryGenerate a Test Alert. This will send a test alert to all configured and enabled remote alert recipients. NOTE: Value returned for the GET command is meaningle…
1.3.6.1.4.1.2.3.51.2.4.1.4NoderemoteAccessIds
1.3.6.1.4.1.2.3.51.2.4.1.4.1TableremoteAccessIdsTablenot-accessiblemandatoryTable of remote access profiles. This table lets you to configure all login profiles. NOTE: By default, the management module comes configured with one login p…
1.3.6.1.4.1.2.3.51.2.4.1.4.1.1RowremoteAccessIdsEntrynot-accessiblemandatoryRemote access entries.
1.3.6.1.4.1.2.3.51.2.4.1.4.1.1.1ColumnremoteAccessIdEntryIndexread-onlymandatoryIndex for Remote access entry.
1.3.6.1.4.1.2.3.51.2.4.1.4.1.1.2ColumnremoteAccessIdEntryUserIdread-writemandatoryRemote access entry null terminated string that contains the userid. It must not be a duplicate of any previously configured ones. This field is only allowed t…
1.3.6.1.4.1.2.3.51.2.4.1.4.1.1.3ColumnremoteAccessIdEntryPasswordread-writemandatoryRemote access password. The password rules are dictated by a combination of the chassis security policy setting (securityPolicySetting) and the user account se…
1.3.6.1.4.1.2.3.51.2.4.1.4.1.1.10ColumnremoteAccessIdEntryPermgroupsread-writemandatoryA list of permission groups for this userid, delmited with a '|'
1.3.6.1.4.1.2.3.51.2.4.1.4.1.1.11ColumnremoteAccessIdEntryLoggedInread-onlymandatoryIndicates if user is currently logged in or not.
1.3.6.1.4.1.2.3.51.2.4.1.4.1.1.12ColumnremoteAccessIdEntryLastLoginread-onlymandatoryTimestamp for the last successful login by the user.
1.3.6.1.4.1.2.3.51.2.4.1.4.1.1.13ColumnremoteAccessIdEntryPwdCompliantread-onlymandatoryIndicates if user complies with all of the password rules currently in effect.
1.3.6.1.4.1.2.3.51.2.4.1.4.1.1.14ColumnremoteAccessIdEntryPwdExpread-onlymandatoryThe number of days until the user's current password expires.
1.3.6.1.4.1.2.3.51.2.4.1.4.1.1.15ColumnremoteAccessIdEntryDormantread-onlymandatoryIndicates if the user account has been inactive for a specified amount of time based on inactivityAlertDisablePeriod in the customSecuritySettings section.
1.3.6.1.4.1.2.3.51.2.4.1.4.1.1.16ColumnremoteAccessIdEntryStateread-onlymandatoryIndicates the state of the user: Active - normal state Disabled - user cannot use account until enabled by a supervisor or chassis user account manager. An acc…
1.3.6.1.4.1.2.3.51.2.4.1.4.1.1.17ColumnremoteAccessIdEntryActionread-writemandatoryActions that only a supervisor or chassis user account manager can perform for each user id: Enable - enables an account in the Disabled state Disable - disabl…
1.3.6.1.4.1.2.3.51.2.4.1.4.1.1.18ColumnremoteAccessIdEntrySessionCountread-onlymandatoryThe number of sessions the user is currently logged in to.
1.3.6.1.4.1.2.3.51.2.4.1.4.1.1.19ColumnremoteAccessIdEntryMaxSessionsread-writemandatoryThe maximum number of simultaneous active sessions allowed for the user. If the value is 0, this option is disabled. The minimum value is 1 and the maximum val…
1.3.6.1.4.1.2.3.51.2.4.1.4.1.1.20ColumnremoteAccessIdEntryStatusread-writemandatoryThis object manages the creation and deletion of this entry. The steps recommended to add a new group are: 1. Create a new entry in this table remoteAccessIdEn…
1.3.6.1.4.1.2.3.51.2.4.1.4.1.1.21ColumnremoteAccessIdEntryIPMIProvisionedread-writemandatoryIndicates if the user has been provisioned as an IPMI account. If this is user is provisioned as an IPMI account, the nodes (scope) and authorities will be det…
1.3.6.1.4.1.2.3.51.2.4.1.4.1.1.22ColumnremoteAccessIdEntrySNMPv3Provisionedread-writemandatoryIndicates if the user has been provisioned as an SNMPv3 account. If this is user is provisioned as an SNMPv3 account, the nodes (scope) and authorities will be…
1.3.6.1.4.1.2.3.51.2.4.1.4.3TableremoteAccessRBSroleTablenot-accessiblemandatoryTable of RBS User Role profiles.
1.3.6.1.4.1.2.3.51.2.4.1.4.3.1RowremoteAccessRBSroleEntrynot-accessiblemandatoryUser Role entries.
1.3.6.1.4.1.2.3.51.2.4.1.4.3.1.1ColumnroleIndexread-onlymandatoryIndex for RBS User Role entry.
1.3.6.1.4.1.2.3.51.2.4.1.4.3.1.2ColumnroleIdread-writemandatoryRemote access RBS role entry null terminated string that contains the permission group ID. It must not be a duplicate of any previously configured ones. This f…
1.3.6.1.4.1.2.3.51.2.4.1.4.3.1.3ColumnrbsSupervisorread-writemandatoryUser has no restrictions.
1.3.6.1.4.1.2.3.51.2.4.1.4.3.1.4ColumnrbsOperatorread-writemandatoryUser has read-only access, and cannot perform any save, modify, clear, or state affecting operations (e.g. restart MM, restore defaults, upgrade the firmware, …
1.3.6.1.4.1.2.3.51.2.4.1.4.3.1.5ColumnrbsChassisOperatorread-writemandatoryUser has ability to browse status and properties of chassis components (MM, chassis fans, midplane, power modules). Ability to backup MM configuration to a fil…
1.3.6.1.4.1.2.3.51.2.4.1.4.3.1.6ColumnrbsChassisAccountManagementread-writemandatoryUser can add/modify/delete user login profiles. Ability to backup MM configuration to a file. Changing global login settings require chassis configuration auth…
1.3.6.1.4.1.2.3.51.2.4.1.4.3.1.7ColumnrbsChassisLogManagementread-writemandatoryUser has ability to clear the MM event log, change log policy settings, and backup MM configuration to a file.
1.3.6.1.4.1.2.3.51.2.4.1.4.3.1.8ColumnrbsChassisConfigurationread-writemandatoryUser can modify and save any chassis configuration parameter (except user profiles and event log settings). Ability to restore MM factory defaults if the user …
1.3.6.1.4.1.2.3.51.2.4.1.4.3.1.9ColumnrbsChassisAdministrationread-writemandatoryUser has ability to do MM firmware updates, modify chassis LEDs, restore MM factory defaults if the user also has chassis configuration permissions. Ability to…
1.3.6.1.4.1.2.3.51.2.4.1.4.3.1.10ColumnrbsBladeOperatorread-writemandatoryUser has ability to browse status and properties of blades.
1.3.6.1.4.1.2.3.51.2.4.1.4.3.1.11ColumnrbsBladeRemotePresenceread-writemandatoryUser has ability to access the blades remote console. The ability to issue the CLI console command to start an SOL session to a blade will also require this au…
1.3.6.1.4.1.2.3.51.2.4.1.4.3.1.12ColumnrbsBladeConfigurationread-writemandatoryUser can modify and save any blade configuration parameter.
1.3.6.1.4.1.2.3.51.2.4.1.4.3.1.13ColumnrbsBladeAdministrationread-writemandatoryUser can power on/off and restart blades, activate standby blades, do firmware updates, and modify blade LEDs.
1.3.6.1.4.1.2.3.51.2.4.1.4.3.1.14ColumnrbsSwitchModuleOperatorread-writemandatoryUser has ability to browse status and properties of I/O Modules, and to ping I/O Modules.
1.3.6.1.4.1.2.3.51.2.4.1.4.3.1.15ColumnrbsSwitchModuleConfigurationread-writemandatoryUser can modify the I/O Module IP address, configure I/O Module Advanced Management parameters, and restore factory defaults on an I/O Module. Note that a user…
1.3.6.1.4.1.2.3.51.2.4.1.4.3.1.16ColumnrbsSwitchModuleAdministrationread-writemandatoryUser can power on/off and restart the I/O Modules, update I/O Module firmware, enable/disable the Fast POST and External Ports of an I/O Module. Note that a us…
1.3.6.1.4.1.2.3.51.2.4.1.4.3.1.23ColumnrbsEntryStatusread-writemandatoryThis object manages the creation and deletion of this entry. The steps recommended to add a new group are: 1. Create a new entry in this table rbsEntryStatus =…
1.3.6.1.4.1.2.3.51.2.4.1.4.4TableremoteAccessRBSscopeTablenot-accessiblemandatoryTable of RBS User Scope profiles.
1.3.6.1.4.1.2.3.51.2.4.1.4.4.1RowremoteAccessRBSscopeEntrynot-accessiblemandatoryUser Scope entries.
1.3.6.1.4.1.2.3.51.2.4.1.4.4.1.1ColumnscopeIndexread-onlymandatoryIndex for RBS User Scope Entry.
1.3.6.1.4.1.2.3.51.2.4.1.4.4.1.2ColumnscopeIdread-onlymandatoryRemote access RBS scope entry null terminated string that contains the permission group ID.
1.3.6.1.4.1.2.3.51.2.4.1.4.4.1.3ColumnrbsChassisread-writemandatoryUser has access to the MM and chassis functions.
1.3.6.1.4.1.2.3.51.2.4.1.4.4.1.4ColumnrbsBlade1read-writemandatoryUser has access to the blade in slot 1.
1.3.6.1.4.1.2.3.51.2.4.1.4.4.1.5ColumnrbsBlade2read-writemandatoryUser has access to the blade in slot 2.
1.3.6.1.4.1.2.3.51.2.4.1.4.4.1.6ColumnrbsBlade3read-writemandatoryUser has access to the blade in slot 3.
1.3.6.1.4.1.2.3.51.2.4.1.4.4.1.7ColumnrbsBlade4read-writemandatoryUser has access to the blade in slot 4.
1.3.6.1.4.1.2.3.51.2.4.1.4.4.1.8ColumnrbsBlade5read-writemandatoryUser has access to the blade in slot 5.
1.3.6.1.4.1.2.3.51.2.4.1.4.4.1.9ColumnrbsBlade6read-writemandatoryUser has access to the blade in slot 6.
1.3.6.1.4.1.2.3.51.2.4.1.4.4.1.10ColumnrbsBlade7read-writemandatoryUser has access to the blade in slot 7.
1.3.6.1.4.1.2.3.51.2.4.1.4.4.1.11ColumnrbsBlade8read-writemandatoryUser has access to the blade in slot 8.
1.3.6.1.4.1.2.3.51.2.4.1.4.4.1.12ColumnrbsBlade9read-writemandatoryUser has access to the blade in slot 9.
1.3.6.1.4.1.2.3.51.2.4.1.4.4.1.13ColumnrbsBlade10read-writemandatoryUser has access to the blade in slot 10.
1.3.6.1.4.1.2.3.51.2.4.1.4.4.1.14ColumnrbsBlade11read-writemandatoryUser has access to the blade in slot 11.
1.3.6.1.4.1.2.3.51.2.4.1.4.4.1.15ColumnrbsBlade12read-writemandatoryUser has access to the blade in slot 12.
1.3.6.1.4.1.2.3.51.2.4.1.4.4.1.16ColumnrbsBlade13read-writemandatoryUser has access to the blade in slot 13.
1.3.6.1.4.1.2.3.51.2.4.1.4.4.1.17ColumnrbsBlade14read-writemandatoryUser has access to the blade in slot 14.
1.3.6.1.4.1.2.3.51.2.4.1.4.4.1.18ColumnrbsSwitch1read-writemandatoryUser has access to I/O module 1.
1.3.6.1.4.1.2.3.51.2.4.1.4.4.1.19ColumnrbsSwitch2read-writemandatoryUser has access to I/O module 2.
1.3.6.1.4.1.2.3.51.2.4.1.4.4.1.20ColumnrbsSwitch3read-writemandatoryUser has access to I/O module 3.
1.3.6.1.4.1.2.3.51.2.4.1.4.4.1.21ColumnrbsSwitch4read-writemandatoryUser has access to I/O module 4.
1.3.6.1.4.1.2.3.51.2.4.1.4.4.1.22ColumnrbsSwitch5read-writemandatoryUser has access to I/O module 5.
1.3.6.1.4.1.2.3.51.2.4.1.4.4.1.23ColumnrbsSwitch6read-writemandatoryUser has access to I/O module 6.
1.3.6.1.4.1.2.3.51.2.4.1.4.4.1.24ColumnrbsSwitch7read-writemandatoryUser has access to I/O module 7.
1.3.6.1.4.1.2.3.51.2.4.1.4.4.1.25ColumnrbsSwitch8read-writemandatoryUser has access to I/O module 8.
1.3.6.1.4.1.2.3.51.2.4.1.4.4.1.26ColumnrbsSwitch9read-writemandatoryUser has access to I/O module 9.
1.3.6.1.4.1.2.3.51.2.4.1.4.4.1.27ColumnrbsSwitch10read-writemandatoryUser has access to I/O module 10.
1.3.6.1.4.1.2.3.51.2.4.1.4.9ScalarcmmCentralManagerIPMISNMPv3read-writemandatoryIndicates whether CMM is the central manager of the IPMI and SNMPv3 accounts. For a write, it can only be set to enabled. Once the CMM state is enabled, it can…
1.3.6.1.4.1.2.3.51.2.4.1.5NodeuserInterfaces
1.3.6.1.4.1.2.3.51.2.4.1.5.1Scalarcliread-writemandatoryEnable/Disable CLI access to the MM (telnet and SSH). The value enabled(3) means both telnet and ssh are enabled.
1.3.6.1.4.1.2.3.51.2.4.1.5.2Scalarsnmpread-writemandatoryEnable/Disable SNMP v1 and v3 access to the MM. The value enabled(3) means both telnet and ssh are enabled.
1.3.6.1.4.1.2.3.51.2.4.1.5.3Scalartcmread-writemandatoryEnable/Disable TCP command mode (TCM) access to the MM. A value of 0 means disabled, any value from 1 to 20 means enabled. NOTE: MM will provide a max of 20 co…
1.3.6.1.4.1.2.3.51.2.4.1.5.4Scalarwebread-writemandatoryEnable/Disable Web access (HTTP/HTTPS) to the MM. NOTE: Disabling web access to the MM will cause all currently active web sessions to disconnect, and you will…
1.3.6.1.4.1.2.3.51.2.4.1.5.5Scalarstcmread-writemandatoryEnable/Disable secure TCP command mode (STCM) access to the MM. A value of 0 means disabled, any value from 1 to 20 means enabled. NOTE: MM will provide a max …
1.3.6.1.4.1.2.3.51.2.4.1.6NodemmSshClientAuth
1.3.6.1.4.1.2.3.51.2.4.1.6.1TablemmSshClientAuthPubKeyTablenot-accessiblemandatoryA table that contains client authentication public key information.
1.3.6.1.4.1.2.3.51.2.4.1.6.1.1RowmmSshClientAuthPubKeyEntrynot-accessiblemandatoryA information list about a particular SSH public key used for client authentication. The primary table index is the same value as the associated remoteAccessId…
1.3.6.1.4.1.2.3.51.2.4.1.6.1.1.1ColumnmmSshClientAuthRemoteAccessIdIndexread-onlymandatoryThe primary table index is the same value as the associated remoteAccessIdEntryIndex used as an index into the remoteAccessIdsTable.
1.3.6.1.4.1.2.3.51.2.4.1.6.1.1.2ColumnmmSshClientAuthPubKeyIndexread-onlymandatoryThe secondary table index used to select one of the client authentication public keys for a particular remote access Id. The index is an integer value from 1 t…
1.3.6.1.4.1.2.3.51.2.4.1.6.1.1.3ColumnmmSshClientAuthPubKeyTyperead-onlymandatoryThe type of the SSH public key represented by this entry.
1.3.6.1.4.1.2.3.51.2.4.1.6.1.1.4ColumnmmSshClientAuthPubKeySizeread-onlymandatoryThe size of the SSH public key represented by this entry.
1.3.6.1.4.1.2.3.51.2.4.1.6.1.1.5ColumnmmSshClientAuthPubKeyFingerprintread-onlymandatoryThe RSA fingerprint of the SSH public key represented by this entry. This value can be used with the SSH client to verify, on the initial connection, that the …
1.3.6.1.4.1.2.3.51.2.4.1.6.1.1.6ColumnmmSshClientAuthPubKeyAcceptFromread-writemandatoryThis is a filter that describes the set of SSH client IP addresses and host names that can establish SSH connections to the MM authenticated by the public key …
1.3.6.1.4.1.2.3.51.2.4.1.6.1.1.7ColumnmmSshClientAuthPubKeyCommentread-writemandatoryThis is a descriptive string that the administrator may use to help identify the public key represented by this entry. It serves no function in the operation o…
1.3.6.1.4.1.2.3.51.2.4.1.6.1.1.8ColumnmmSshClientAuthPubKeyActionread-writemandatoryimport(1) starts the TFTP file transfer of an SSH client authentication public key from the TFTP server to the MM. The import operation is only accepted if the…
1.3.6.1.4.1.2.3.51.2.4.1.6.1.1.9ColumnmmSshClientAuthPubKeyEntryStatusread-writemandatoryThis object manages the creation and deletion of this entry. The steps recommended to install and to activate a new client authorization public key are: 1. Set…
1.3.6.1.4.1.2.3.51.2.4.1.6.1.1.10ColumnmmSshClientAuthPubKeyUserIdread-onlymandatoryThe userid for the key entry.
1.3.6.1.4.1.2.3.51.2.4.1.6.2ScalarmmSshClientAuthPubKeyUnusedread-onlymandatoryThe number of available storage locations that may be used to install additional Client Authentication Public Keys. This number decreases by one when a new key…
1.3.6.1.4.1.2.3.51.2.4.1.6.3ScalarmmSshClientAuthPubKeyTftpServerread-writemandatoryIP address or host name of the TFTP server where an SSH client authentication public key is to be installed from or exported to. The address must be entered in…
1.3.6.1.4.1.2.3.51.2.4.1.6.4ScalarmmSshClientAuthPubKeyFileNameread-writemandatoryFile name on the TFTP server of an SSH client authentication public key.
1.3.6.1.4.1.2.3.51.2.4.1.6.5ScalarmmSshClientAuthPubKeyFileFormatread-writemandatoryFile format of SSH client authentication public key files imported from or exported to the TFTP file server.
1.3.6.1.4.1.2.3.51.2.4.1.7NodegroupProfiles
1.3.6.1.4.1.2.3.51.2.4.1.7.1TablegroupIdsTablenot-accessiblemandatoryTable of Group profiles. This table lets you to configure all group profiles. You can define up to 16 unique profiles.
1.3.6.1.4.1.2.3.51.2.4.1.7.1.1RowgroupIdsEntrynot-accessiblemandatoryGroup ID entries.
1.3.6.1.4.1.2.3.51.2.4.1.7.1.1.1ColumngroupIndexread-onlymandatoryIndex for Group IDs entry.
1.3.6.1.4.1.2.3.51.2.4.1.7.1.1.2ColumngroupIdread-writemandatoryGroup ID. It is a null terminated string that contains the group-id. It must not be a duplicate of any previously configured ones.
1.3.6.1.4.1.2.3.51.2.4.1.7.1.1.3ColumngroupRoleread-onlymandatoryGroup Role. It indicates if the group has supervisor, operator, or custom access.
1.3.6.1.4.1.2.3.51.2.4.1.7.1.1.9ColumngroupEntryStatusread-writemandatoryThis object manages the creation and deletion of this entry. The steps recommended to add a new group are: 1. Create a new entry in this table groupEntryStatus…
1.3.6.1.4.1.2.3.51.2.4.1.7.2TablegroupRBSroleTablenot-accessiblemandatoryTable of Group Role profiles.
1.3.6.1.4.1.2.3.51.2.4.1.7.2.1RowgroupRBSroleEntrynot-accessiblemandatoryGroup Role entries.
1.3.6.1.4.1.2.3.51.2.4.1.7.2.1.1ColumngroupRBSroleIndexread-onlymandatoryIndex for Group Role entry.
1.3.6.1.4.1.2.3.51.2.4.1.7.2.1.2ColumngroupRBSroleIdread-onlymandatoryGroup ID
1.3.6.1.4.1.2.3.51.2.4.1.7.2.1.3ColumngroupRBSSupervisorread-writemandatoryGroup has no restrictions.
1.3.6.1.4.1.2.3.51.2.4.1.7.2.1.4ColumngroupRBSOperatorread-writemandatoryGroup has read-only access, and cannot perform any save, modify, clear, or state affecting operations (e.g. restart MM, restore defaults, upgrade the firmware,…
1.3.6.1.4.1.2.3.51.2.4.1.7.2.1.5ColumngroupRBSChassisOperatorread-writemandatoryGroup has ability to browse status and properties of chassis components (MM, chassis fans, midplane, power modules). Ability to backup MM configuration to a fi…
1.3.6.1.4.1.2.3.51.2.4.1.7.2.1.6ColumngroupRBSChassisAccountManagementread-writemandatoryGroup can add/modify/delete user login profiles. Ability to backup MM configuration to a file. Changing global login settings require chassis configuration aut…
1.3.6.1.4.1.2.3.51.2.4.1.7.2.1.7ColumngroupRBSChassisLogManagementread-writemandatoryGroup has ability to clear the MM event log, change log policy settings, and backup MM configuration to a file.
1.3.6.1.4.1.2.3.51.2.4.1.7.2.1.8ColumngroupRBSChassisConfigurationread-writemandatoryGroup can modify and save any chassis configuration parameter (except user profiles and event log settings). Ability to restore MM factory defaults if the grou…
1.3.6.1.4.1.2.3.51.2.4.1.7.2.1.9ColumngroupRBSChassisAdministrationread-writemandatoryGroup has ability to do MM firmware updates, modify chassis LEDs, restore MM factory defaults if the group also has chassis configuration permissions. Ability …
1.3.6.1.4.1.2.3.51.2.4.1.7.2.1.10ColumngroupRBSBladeOperatorread-writemandatoryGroup has ability to browse status and properties of blades.
1.3.6.1.4.1.2.3.51.2.4.1.7.2.1.11ColumngroupRBSBladeRemotePresenceread-writemandatoryGroup has ability to access the blade remote console The ability to issue the CLI console command to start an SOL session to a blade will also require this aut…
1.3.6.1.4.1.2.3.51.2.4.1.7.2.1.12ColumngroupRBSBladeConfigurationread-writemandatoryGroup can modify and save any blade configuration parameter.
1.3.6.1.4.1.2.3.51.2.4.1.7.2.1.13ColumngroupRBSBladeAdministrationread-writemandatoryGroup can power on/off and restart blades, activate standby blades, do firmware updates, and modify blade LEDs.
1.3.6.1.4.1.2.3.51.2.4.1.7.2.1.14ColumngroupRBSSwitchModuleOperatorread-writemandatoryGroup has ability to browse status and properties of I/O Modules, and to ping I/O Modules.
1.3.6.1.4.1.2.3.51.2.4.1.7.2.1.15ColumngroupRBSSwitchModuleConfigurationread-writemandatoryGroup can modify the I/O Module IP address, configure I/O Module Advanced Management parameters, and restore factory defaults on an I/O Module. Note that a gro…
1.3.6.1.4.1.2.3.51.2.4.1.7.2.1.16ColumngroupRBSSwitchModuleAdministrationread-writemandatoryGroup can power on/off and restart the I/O Modules, update I/O Module firmware, enable/disable the Fast POST and External Ports of an I/O Module. Note that a g…
1.3.6.1.4.1.2.3.51.2.4.1.7.3TablegroupRBSscopeTablenot-accessiblemandatoryTable of Group Scope profiles.
1.3.6.1.4.1.2.3.51.2.4.1.7.3.1RowgroupRBSscopeEntrynot-accessiblemandatoryGroup Scope entries.
1.3.6.1.4.1.2.3.51.2.4.1.7.3.1.1ColumngroupRBSscopeIndexread-onlymandatoryIndex for Group Scope Entry.
1.3.6.1.4.1.2.3.51.2.4.1.7.3.1.2ColumngroupRBSscopeIdread-onlymandatoryGroup ID
1.3.6.1.4.1.2.3.51.2.4.1.7.3.1.3ColumngroupRBSChassisread-writemandatoryGroup has access to the MM and chassis functions.
1.3.6.1.4.1.2.3.51.2.4.1.7.3.1.4ColumngroupRBSBlade1read-writemandatoryGroup has access to the blade in slot 1.
1.3.6.1.4.1.2.3.51.2.4.1.7.3.1.5ColumngroupRBSBlade2read-writemandatoryGroup has access to the blade in slot 2.
1.3.6.1.4.1.2.3.51.2.4.1.7.3.1.6ColumngroupRBSBlade3read-writemandatoryGroup has access to the blade in slot 3.
1.3.6.1.4.1.2.3.51.2.4.1.7.3.1.7ColumngroupRBSBlade4read-writemandatoryGroup has access to the blade in slot 4.
1.3.6.1.4.1.2.3.51.2.4.1.7.3.1.8ColumngroupRBSBlade5read-writemandatoryGroup has access to the blade in slot 5.
1.3.6.1.4.1.2.3.51.2.4.1.7.3.1.9ColumngroupRBSBlade6read-writemandatoryGroup has access to the blade in slot 6.
1.3.6.1.4.1.2.3.51.2.4.1.7.3.1.10ColumngroupRBSBlade7read-writemandatoryGroup has access to the blade in slot 7.
1.3.6.1.4.1.2.3.51.2.4.1.7.3.1.11ColumngroupRBSBlade8read-writemandatoryGroup has access to the blade in slot 8.
1.3.6.1.4.1.2.3.51.2.4.1.7.3.1.12ColumngroupRBSBlade9read-writemandatoryGroup has access to the blade in slot 9.
1.3.6.1.4.1.2.3.51.2.4.1.7.3.1.13ColumngroupRBSBlade10read-writemandatoryGroup has access to the blade in slot 10.
1.3.6.1.4.1.2.3.51.2.4.1.7.3.1.14ColumngroupRBSBlade11read-writemandatoryGroup has access to the blade in slot 11.
1.3.6.1.4.1.2.3.51.2.4.1.7.3.1.15ColumngroupRBSBlade12read-writemandatoryGroup has access to the blade in slot 12.
1.3.6.1.4.1.2.3.51.2.4.1.7.3.1.16ColumngroupRBSBlade13read-writemandatoryGroup has access to the blade in slot 13.
1.3.6.1.4.1.2.3.51.2.4.1.7.3.1.17ColumngroupRBSBlade14read-writemandatoryGroup has access to the blade in slot 14.
1.3.6.1.4.1.2.3.51.2.4.1.7.3.1.18ColumngroupRBSSwitch1read-writemandatoryGroup has access to I/O module 1.
1.3.6.1.4.1.2.3.51.2.4.1.7.3.1.19ColumngroupRBSSwitch2read-writemandatoryGroup has access to I/O module 2.
1.3.6.1.4.1.2.3.51.2.4.1.7.3.1.20ColumngroupRBSSwitch3read-writemandatoryGroup has access to I/O module 3.
1.3.6.1.4.1.2.3.51.2.4.1.7.3.1.21ColumngroupRBSSwitch4read-writemandatoryGroup has access to I/O module 4.
1.3.6.1.4.1.2.3.51.2.4.1.7.3.1.22ColumngroupRBSSwitch5read-writemandatoryGroup has access to I/O module 5.
1.3.6.1.4.1.2.3.51.2.4.1.7.3.1.23ColumngroupRBSSwitch6read-writemandatoryGroup has access to I/O module 6.
1.3.6.1.4.1.2.3.51.2.4.1.7.3.1.24ColumngroupRBSSwitch7read-writemandatoryGroup has access to I/O module 7.
1.3.6.1.4.1.2.3.51.2.4.1.7.3.1.25ColumngroupRBSSwitch8read-writemandatoryGroup has access to I/O module 8.
1.3.6.1.4.1.2.3.51.2.4.1.7.3.1.26ColumngroupRBSSwitch9read-writemandatoryGroup has access to I/O module 9.
1.3.6.1.4.1.2.3.51.2.4.1.7.3.1.27ColumngroupRBSSwitch10read-writemandatoryGroup has access to I/O module 10.
1.3.6.1.4.1.2.3.51.2.4.2NoderemoteAlerts
1.3.6.1.4.1.2.3.51.2.4.2.1NoderemoteAlertsCrit
1.3.6.1.4.1.2.3.51.2.4.2.1.5ScalarcritPowerread-writemandatoryGenerate an alert if any of the system power supplies fail.
1.3.6.1.4.1.2.3.51.2.4.2.1.10ScalarcritBladeread-writemandatoryGenerate an alert for any critical error condition on a blade.
1.3.6.1.4.1.2.3.51.2.4.2.1.11ScalarcritIOread-writemandatoryGenerate an alert for any critical error condition on I/O module.
1.3.6.1.4.1.2.3.51.2.4.2.1.12ScalarcritStorageread-writemandatoryGenerate an alert for any critical error condition on a Storage module.
1.3.6.1.4.1.2.3.51.2.4.2.1.13ScalarcritChassisread-writemandatoryGenerate an alert for any critical error condition on chassis.
1.3.6.1.4.1.2.3.51.2.4.2.1.14ScalarcritFanread-writemandatoryGenerate an alert for any critical error condition on cooling devices.
1.3.6.1.4.1.2.3.51.2.4.2.2NoderemoteAlertsNonCrit
1.3.6.1.4.1.2.3.51.2.4.2.2.10ScalarwarnLogFullread-writemandatoryGenerate an alert if the system log reaches 100% full.
1.3.6.1.4.1.2.3.51.2.4.2.2.15ScalarwarnBladeread-writemandatoryGenerate an alert for any warning condition on a blade.
1.3.6.1.4.1.2.3.51.2.4.2.2.16ScalarwarnIOread-writemandatoryGenerate an alert for any warning condition on I/O module.
1.3.6.1.4.1.2.3.51.2.4.2.2.17ScalarwarnStorageread-writemandatoryGenerate an alert for any warning condition on a Storage module.
1.3.6.1.4.1.2.3.51.2.4.2.2.18ScalarwarnPowerread-writemandatoryGenerate an alert for any warning condition on power module.
1.3.6.1.4.1.2.3.51.2.4.2.2.19ScalarwarnChassisread-writemandatoryGenerate an alert for any warning condition on chassis.
1.3.6.1.4.1.2.3.51.2.4.2.2.20ScalarwarnFanread-writemandatoryGenerate an alert for any warning condition on cooling devices.
1.3.6.1.4.1.2.3.51.2.4.2.3NoderemoteAlertsSystem
1.3.6.1.4.1.2.3.51.2.4.2.3.10ScalarsystemInventoryread-writemandatoryGenerate an alert if the a processor blade or media tray is added or removed.
1.3.6.1.4.1.2.3.51.2.4.2.3.11ScalarsystemLog75PctFullread-writemandatoryGenerate an alert if the system log reaches 75% full.
1.3.6.1.4.1.2.3.51.2.4.2.3.12ScalarnetworkChangeNotificationread-writemandatoryGenerate an alert if the MM has restarted and the internal network has initialized successfully, or if an IP address change via a source other than the managem…
1.3.6.1.4.1.2.3.51.2.4.2.3.15ScalarsystemRemoteLoginread-writemandatoryGenerate an alert if the system detects a new user logged in from a remote site.
1.3.6.1.4.1.2.3.51.2.4.2.3.16ScalarsystemBladeread-writemandatoryGenerate an alert for any informational condition on a blade.
1.3.6.1.4.1.2.3.51.2.4.2.3.17ScalarsystemIOread-writemandatoryGenerate an alert for any informational condition on I/O module.
1.3.6.1.4.1.2.3.51.2.4.2.3.18ScalarsystemStorageread-writemandatoryGenerate an alert for any informational condition on a Storage module.
1.3.6.1.4.1.2.3.51.2.4.2.3.19ScalarsystemPowerread-writemandatoryGenerate an alert for any informational condition on power module.
1.3.6.1.4.1.2.3.51.2.4.2.3.20ScalarsystemChassisread-writemandatoryGenerate an alert for any informational condition on chassis.
1.3.6.1.4.1.2.3.51.2.4.2.3.21ScalarsystemFanread-writemandatoryGenerate an alert for any informational condition on cooling device.
1.3.6.1.4.1.2.3.51.2.4.2.3.22ScalarsystemPWRDOread-writemandatoryGenerate an alert for any informational condition on power on and power off.
1.3.6.1.4.1.2.3.51.2.4.3NodesecuritySettings
1.3.6.1.4.1.2.3.51.2.4.3.2ScalartrespassWarningread-writemandatoryIf enabled, a customizable trespass warning message is displayed via the Web and CLI interfaces.
1.3.6.1.4.1.2.3.51.2.4.3.3ScalartrespassWarningDefaultread-writemandatoryReset the trespass warning to default value. NOTE: Value returned for the GET command is meaningless for this MIB object.
1.3.6.1.4.1.2.3.51.2.4.3.4ScalartrespassMessageread-writemandatoryThe value of the trespass warning message.
1.3.6.1.4.1.2.3.51.2.4.3.5NodechassisSecuritySettings
1.3.6.1.4.1.2.3.51.2.4.3.5.1ScalarsecurityPolicySettingread-writemandatoryDetermines chassis security policy. legacy mode(0) or secure mode(1). unknown(255) returned when policy can't be set or determined.
1.3.6.1.4.1.2.3.51.2.4.3.5.2ScalarsecurityPolicyStateread-onlymandatoryDetermines chassis security policy state. If pending(0), check securityPolicyStatusTable for details on actions needed, to make fully active.
1.3.6.1.4.1.2.3.51.2.4.3.5.3TablesecurityPolicyStatusTablenot-accessiblemandatoryTable of pending security policy status.
1.3.6.1.4.1.2.3.51.2.4.3.5.3.1RowsecurityPolicyStatusEntrynot-accessiblemandatoryPending security policy status entry
1.3.6.1.4.1.2.3.51.2.4.3.5.3.1.1ColumnsecurityPolicyStatusIndexread-onlymandatoryPending Security policy status index.
1.3.6.1.4.1.2.3.51.2.4.3.5.3.1.2ColumnsecurityPolicyStatusComponentTyperead-onlymandatoryIndicates Component type and location with pending security status.
1.3.6.1.4.1.2.3.51.2.4.3.5.3.1.3ColumnsecurityPolicyStatusBayIdread-onlymandatoryBay location of specific component. NOTE: securityPolicyStatusComponentType enumeration also indicates location.
1.3.6.1.4.1.2.3.51.2.4.3.5.3.1.4ColumnsecurityPolicyStatusSummaryread-onlymandatorySummary of pending security status for the component.
1.3.6.1.4.1.2.3.51.2.4.3.5.3.1.5ColumnsecurityPolicyStatusDetailsread-onlymandatoryDetails of pending security status for the component.
1.3.6.1.4.1.2.3.51.2.4.3.5.10Nodecryptography
1.3.6.1.4.1.2.3.51.2.4.3.5.10.5ScalarcryptographySummaryread-onlymandatoryThe current level and summary description of the cryptographic configuration.
1.3.6.1.4.1.2.3.51.2.4.3.5.10.15ScalarcryptographyModeread-writemandatoryThe NIST cryptographic mode setting. A successful setting of this object initiates a reboot of the CMM within a few seconds.
1.3.6.1.4.1.2.3.51.2.4.3.5.10.18TablecryptographyModeDetailsTablenot-accessiblemandatoryA table of information indicating any NIST customization details and any reasons that the CMM cannot transition to the desired NIST mode.
1.3.6.1.4.1.2.3.51.2.4.3.5.10.18.1RowcryptographyModeDetailsEntrynot-accessiblemandatoryCryptography mode status entry
1.3.6.1.4.1.2.3.51.2.4.3.5.10.18.1.1ColumncryptographyModeDetailsIndexread-onlymandatoryCryptography mode details index.
1.3.6.1.4.1.2.3.51.2.4.3.5.10.18.1.2ColumncryptographyModeDetailsTyperead-onlymandatoryIndication of what type of message is reported for this entry.
1.3.6.1.4.1.2.3.51.2.4.3.5.10.18.1.3ColumncryptographyModeDetailsDescriptionread-onlymandatoryMessage containing details for this cryptography entry.
1.3.6.1.4.1.2.3.51.2.4.3.5.10.20TablecryptographyModeComponentTablenot-accessiblemandatoryA table of information listing any IOMs or nodes that require a firmware update in order for the CMM to transition to the new mode.
1.3.6.1.4.1.2.3.51.2.4.3.5.10.20.1RowcryptographyModeComponentEntrynot-accessiblemandatoryCryptography mode component entry
1.3.6.1.4.1.2.3.51.2.4.3.5.10.20.1.1ColumncryptographyModeComponentIndexread-onlymandatoryCryptography mode component index.
1.3.6.1.4.1.2.3.51.2.4.3.5.10.20.1.2ColumncryptographyModeComponentIdread-onlymandatoryA component identifier for an IOM or node in the form: ts:mm. t(type), s(slot number), mm sub-slot number.
1.3.6.1.4.1.2.3.51.2.4.3.5.10.25ScalarcryptographicCipherread-writemandatoryThe cryptographic cipher suite setting.
1.3.6.1.4.1.2.3.51.2.4.3.5.10.30TablecryptographyCipherComponentTablenot-accessiblemandatoryA table of information listing any IOMs or nodes that are out of compliance with regards to the cipher suite setting and are therefore preventing the CMM from …
1.3.6.1.4.1.2.3.51.2.4.3.5.10.30.1RowcryptographyCipherComponentEntrynot-accessiblemandatoryCryptography cipher component entry
1.3.6.1.4.1.2.3.51.2.4.3.5.10.30.1.1ColumncryptographyCipherComponentIndexread-onlymandatoryCryptography cipher component index.
1.3.6.1.4.1.2.3.51.2.4.3.5.10.30.1.2ColumncryptographyCipherComponentIdread-onlymandatoryA component identifier for an IOM or node in the form: ts:mm. t(type), s(slot number), mm sub-slot number.
1.3.6.1.4.1.2.3.51.2.4.3.5.15ScalarcipherStrengthread-writemandatoryStrength level of the NIST signing algorithm for certificate authority. None(0) indicates no signing algorithm has been set. When writing a new value to this o…
1.3.6.1.4.1.2.3.51.2.4.4NodespClock
1.3.6.1.4.1.2.3.51.2.4.4.1ScalarspClockDateAndTimeSettingread-writemandatoryMM clock date and time setting. A date-time specification for the local time of day. For example to set the date and time to March 4, 2001 at 06:00:00AM, set t…
1.3.6.1.4.1.2.3.51.2.4.4.2ScalarspClockTimezoneSettingread-writemandatoryMM clock Greenwich Mean Time(GMT) offset and Daylight Saving Time(DST) settings. For write, the value must be a time zone listed in spClockTimezoneTable. The s…
1.3.6.1.4.1.2.3.51.2.4.4.3TablespClockTimezoneTablenot-accessiblemandatoryTable of all time zones listed in zone.tab file
1.3.6.1.4.1.2.3.51.2.4.4.3.1RowspClockTimezoneEntrynot-accessiblemandatoryTime zone entry
1.3.6.1.4.1.2.3.51.2.4.4.3.1.1ColumnspClockTimezoneIndexread-onlymandatoryTime zone table index.
1.3.6.1.4.1.2.3.51.2.4.4.3.1.2ColumnspClockTimezoneIdread-onlymandatoryTime zone instance id.
1.3.6.1.4.1.2.3.51.2.4.4.3.1.3ColumnspClockTimezoneCaptionread-onlymandatoryTime zone caption.
1.3.6.1.4.1.2.3.51.2.4.4.3.1.4ColumnspClockTimezoneDescriptionread-onlymandatoryTime zone description.
1.3.6.1.4.1.2.3.51.2.4.4.3.1.5ColumnspClockTimezoneNameread-onlymandatoryTime zone name.
1.3.6.1.4.1.2.3.51.2.4.4.3.1.6ColumnspClockTimezoneStandardNameread-onlymandatoryTime zone standard name.
1.3.6.1.4.1.2.3.51.2.4.4.3.1.7ColumnspClockTimezoneStandardCaptionread-onlymandatoryTime zone standard caption.
1.3.6.1.4.1.2.3.51.2.4.4.3.1.8ColumnspClockTimezoneDaylightNameread-onlymandatoryTime zone daylight name.
1.3.6.1.4.1.2.3.51.2.4.4.3.1.9ColumnspClockTimezoneDaylightCaptionread-onlymandatoryTime zone daylight caption.
1.3.6.1.4.1.2.3.51.2.4.4.3.1.10ColumnspClockTimezoneCmmOffsetread-onlymandatoryCMM offset.
1.3.6.1.4.1.2.3.51.2.4.4.3.1.11ColumnspClockTimezoneStandardOffsetMinutesread-onlymandatoryStandard GMT offset in minutes.
1.3.6.1.4.1.2.3.51.2.4.4.3.1.12ColumnspClockTimezoneStandardDaylightOffsetMinutesread-onlymandatoryStandard GMT offset in minutes.
1.3.6.1.4.1.2.3.51.2.4.4.3.1.13ColumnspClockTimezoneDaylightDayread-onlymandatoryThere are two different interpretations for this field, depending on the value of DaylightDayOfWeek. In one case, DaylightDay defines the day-in-month on which…
1.3.6.1.4.1.2.3.51.2.4.4.3.1.14ColumnspClockTimezoneDaylightDayOfWeekread-onlymandatoryDay of week daylight saving begins.
1.3.6.1.4.1.2.3.51.2.4.4.3.1.15ColumnspClockTimezoneDaylightMonthread-onlymandatoryMonth daylight saving begins.
1.3.6.1.4.1.2.3.51.2.4.4.3.1.16ColumnspClockTimezoneDaylightStandardDayread-onlymandatoryThere are two different interpretations for this property, depending on the value of StandardDayOfWeek. In one case, StandardDay defines the day-in-month on wh…
1.3.6.1.4.1.2.3.51.2.4.4.3.1.17ColumnspClockTimezoneDaylightStandardDayOfWeekread-onlymandatoryDay of week daylight saving ends.
1.3.6.1.4.1.2.3.51.2.4.4.3.1.18ColumnspClockTimezoneDaylightStandardMonthread-onlymandatoryMonth daylight saving ends.
1.3.6.1.4.1.2.3.51.2.4.4.3.1.19ColumnspClockTimezoneDaylightIntervalInMinutesread-onlymandatoryInterval in minutes (Daylight saving begins).
1.3.6.1.4.1.2.3.51.2.4.4.3.1.20ColumnspClockTimezoneDaylightStandardInMinutesread-onlymandatoryInterval in minutes (Daylight saving ends).
1.3.6.1.4.1.2.3.51.2.4.4.5ScalarspClockTimezoneDaylightStartread-onlymandatoryDST start.
1.3.6.1.4.1.2.3.51.2.4.4.6ScalarspClockTimezoneDaylightEndread-onlymandatoryDST end.
1.3.6.1.4.1.2.3.51.2.4.5NodespIdentification
1.3.6.1.4.1.2.3.51.2.4.5.1ScalarspTxtIdread-writemandatoryText description of the MM. NOTE: Do not put any 'space characters' at end of the string.
1.3.6.1.4.1.2.3.51.2.4.9NodenetworkConfiguration
1.3.6.1.4.1.2.3.51.2.4.9.1NodenetworkInterfaces
1.3.6.1.4.1.2.3.51.2.4.9.1.1NodeextEthernetInterface
1.3.6.1.4.1.2.3.51.2.4.9.1.1.1ScalarextEthernetInterfaceTyperead-onlymandatoryThe type of interface.
1.3.6.1.4.1.2.3.51.2.4.9.1.1.3ScalarextEthernetInterfaceHostNameread-writemandatoryContains the 64 byte null terminated DNS host name for this interface.
1.3.6.1.4.1.2.3.51.2.4.9.1.1.4ScalarextEthernetInterfaceIPAddressread-writemandatoryContains the IP address for the ethernet interface.
1.3.6.1.4.1.2.3.51.2.4.9.1.1.5ScalarextEthernetInterfaceDataRateread-writemandatorySpecifies the data transfer rate to be used over the ethernet interface: 10Mb, 100Mb, 1G or Auto.
1.3.6.1.4.1.2.3.51.2.4.9.1.1.6ScalarextEthernetInterfaceDuplexSettingread-writemandatorySpecifies the duplex settings for the data transfer rate to be used over the ethernet interface: Half, Full, or Auto.
1.3.6.1.4.1.2.3.51.2.4.9.1.1.7ScalarextEthernetInterfaceLAAread-writemandatorySpecifies the locally administered MAC address. The locally administered address must be a hexadecimal value between 000000000000 - FFFFFFFFFFFF. This value mu…
1.3.6.1.4.1.2.3.51.2.4.9.1.1.8ScalarextEthernetInterfaceDhcpEnabledread-writemandatoryDisable or enable DHCP on this interface.
1.3.6.1.4.1.2.3.51.2.4.9.1.1.9ScalarextEthernetInterfaceGatewayIPAddressread-writemandatoryContains the IP address of the gateway/router for the ethernet interface.
1.3.6.1.4.1.2.3.51.2.4.9.1.1.10ScalarextEthernetInterfaceBIAread-onlymandatorySpecifies the burned-in MAC (BIA) address.
1.3.6.1.4.1.2.3.51.2.4.9.1.1.13ScalarextEthernetInterfaceMTUread-writemandatoryContains the Maximum Transmission Unit(MTU) for the ethernet interface
1.3.6.1.4.1.2.3.51.2.4.9.1.1.14ScalarextEthernetInterfaceSubnetMaskread-writemandatoryContains the subnet mask for the ethernet interface
1.3.6.1.4.1.2.3.51.2.4.9.1.1.16NodedhcpEthernetInterface
1.3.6.1.4.1.2.3.51.2.4.9.1.1.16.1ScalardhcpHostNameread-onlymandatoryContains the 64 byte null terminated DNS host name for this interface, assigned by the DHCP server.
1.3.6.1.4.1.2.3.51.2.4.9.1.1.16.2ScalardhcpIPAddressread-onlymandatoryContains the IP address for the ethernet interface, assigned by the DHCP server.
1.3.6.1.4.1.2.3.51.2.4.9.1.1.16.3ScalardhcpGatewayIPAddressread-onlymandatoryContains the IP address of the gateway/router for the ethernet interface, assigned by the DHCP server.
1.3.6.1.4.1.2.3.51.2.4.9.1.1.16.4ScalardhcpSubnetMaskread-onlymandatoryContains the Subnet Mask for the ethernet interface, assigned by the DHCP server.
1.3.6.1.4.1.2.3.51.2.4.9.1.1.16.5ScalardhcpDomainNameread-onlymandatoryContains the 64 byte null terminated Domain Name for this interface, assigned by the DHCP server.
1.3.6.1.4.1.2.3.51.2.4.9.1.1.16.6ScalardhcpDHCPServerread-onlymandatoryContains the DHCP server IP address used to acquire the DHCP settings.
1.3.6.1.4.1.2.3.51.2.4.9.1.1.16.7ScalardhcpPrimaryDNSServerread-onlymandatoryContains the Primary DNS server, assigned by the DHCP server.
1.3.6.1.4.1.2.3.51.2.4.9.1.1.16.8ScalardhcpSecondaryDNSServerread-onlymandatoryContains the Secondary DNS server, assigned by the DHCP server.
1.3.6.1.4.1.2.3.51.2.4.9.1.1.16.9ScalardhcpTertiaryDNSServerread-onlymandatoryContains the tertiary DNS server, assigned by the DHCP server.
1.3.6.1.4.1.2.3.51.2.4.9.1.1.22ScalarextEthernetInterfaceFloatingIPAddressread-writemandatoryContains the floating IP address for the external ethernet interface.
1.3.6.1.4.1.2.3.51.2.4.9.1.3NodestandbyExtEthernetInterface
1.3.6.1.4.1.2.3.51.2.4.9.1.3.1ScalarstandbyExtEthernetInterfaceTyperead-onlymandatoryThe type of interface. NOTE: This MIB object is only applicable to systems with a standby MM.
1.3.6.1.4.1.2.3.51.2.4.9.1.3.3ScalarstandbyExtEthernetInterfaceHostNameread-writemandatoryContains the 64 byte null terminated DNS host name for this interface. NOTE: This MIB object is only applicable to systems with a standby MM.
1.3.6.1.4.1.2.3.51.2.4.9.1.3.4ScalarstandbyExtEthernetInterfaceIPAddressread-writemandatoryContains the IP address for the ethernet interface. NOTE: This MIB object is only applicable to systems with a standby MM.
1.3.6.1.4.1.2.3.51.2.4.9.1.3.5ScalarstandbyExtEthernetInterfaceDataRateread-writemandatorySpecifies the data transfer rate to be used over the ethernet interface: 10Mb, 100Mb, 1G or Auto. NOTE: This MIB object is only applicable to systems with a st…
1.3.6.1.4.1.2.3.51.2.4.9.1.3.6ScalarstandbyExtEthernetInterfaceDuplexSettingread-writemandatorySpecifies the duplex settings for the data transfer rate to be used over the ethernet interface: Half, Full, or Auto. NOTE: This MIB object is only applicable …
1.3.6.1.4.1.2.3.51.2.4.9.1.3.7ScalarstandbyExtEthernetInterfaceLAAread-writemandatorySpecifies the locally administered MAC address. The locally administered address must be a hexadecimal value between 000000000000 - FFFFFFFFFFFF. This value mu…
1.3.6.1.4.1.2.3.51.2.4.9.1.3.8ScalarstandbyExtEthernetInterfaceDhcpEnabledread-writemandatoryDisable or enable DHCP on this interface. NOTE: This MIB object is only applicable to systems with a standby MM.
1.3.6.1.4.1.2.3.51.2.4.9.1.3.9ScalarstandbyExtEthernetInterfaceGatewayIPAddressread-writemandatoryContains the IP address of the gateway/router for the ethernet interface. NOTE: This MIB object is only applicable to systems with a standby MM.
1.3.6.1.4.1.2.3.51.2.4.9.1.3.10ScalarstandbyExtEthernetInterfaceBIAread-onlymandatorySpecifies the burned-in MAC (BIA) address. NOTE: This MIB object is only applicable to systems with a standby MM.
1.3.6.1.4.1.2.3.51.2.4.9.1.3.13ScalarstandbyExtEthernetInterfaceMTUread-writemandatoryContains the Maximum Transmission Unit (MTU) for the ethernet interface. NOTE: This MIB object is only applicable to systems with a standby MM.
1.3.6.1.4.1.2.3.51.2.4.9.1.3.14ScalarstandbyExtEthernetInterfaceSubnetMaskread-writemandatoryContains the subnet mask for the ethernet interface. NOTE: This MIB object is only applicable to systems with a standby MM.
1.3.6.1.4.1.2.3.51.2.4.9.1.3.15ScalaradvancedFailoverread-writemandatoryUser can enable advanced failover. off : no standby network interface ipswap: Standby network interface, swap IPs during failover ipnoswap: Standby network int…
1.3.6.1.4.1.2.3.51.2.4.9.1.3.16NodestandbyDhcpEthernetInterface
1.3.6.1.4.1.2.3.51.2.4.9.1.3.16.1ScalarstandbyDhcpHostNameread-onlymandatoryContains the 64 byte null terminated DNS host name for this interface, assigned by the DHCP server. NOTE: This MIB object is only applicable to systems with a …
1.3.6.1.4.1.2.3.51.2.4.9.1.3.16.2ScalarstandbyDhcpIPAddressread-onlymandatoryContains the IP address for the ethernet interface, assigned by the DHCP server. NOTE: This MIB object is only applicable to systems with a standby MM.
1.3.6.1.4.1.2.3.51.2.4.9.1.3.16.3ScalarstandbyDhcpGatewayIPAddressread-onlymandatoryContains the IP address of the gateway/router for the ethernet interface, assigned by the DHCP server. NOTE: This MIB object is only applicable to systems with…
1.3.6.1.4.1.2.3.51.2.4.9.1.3.16.4ScalarstandbyDhcpSubnetMaskread-onlymandatoryContains the Subnet Mask for the ethernet interface, assigned by the DHCP server. NOTE: This MIB object is only applicable to systems with a standby MM.
1.3.6.1.4.1.2.3.51.2.4.9.1.3.16.5ScalarstandbyDhcpDomainNameread-onlymandatoryContains the 64 byte null terminated Domain Name for this interface, assigned by the DHCP server. NOTE: This MIB object is only applicable to systems with a st…
1.3.6.1.4.1.2.3.51.2.4.9.1.3.16.6ScalarstandbyDhcpDHCPServerread-onlymandatoryContains the DHCP server IP address used to acquire the DHCP settings. NOTE: This MIB object is only applicable to systems with a standby MM.
1.3.6.1.4.1.2.3.51.2.4.9.1.3.16.7ScalarstandbyDhcpPrimaryDNSServerread-onlymandatoryContains the Primary DNS server, assigned by the DHCP server. NOTE: This MIB object is only applicable to systems with a standby MM.
1.3.6.1.4.1.2.3.51.2.4.9.1.3.16.8ScalarstandbyDhcpSecondaryDNSServerread-onlymandatoryContains the Secondary DNS server, assigned by the DHCP server. NOTE: This MIB object is only applicable to systems with a standby MM.
1.3.6.1.4.1.2.3.51.2.4.9.1.3.16.9ScalarstandbyDhcpTertiaryDNSServerread-onlymandatoryContains the tertiary DNS server, assigned by the DHCP server. NOTE: This MIB object is only applicable to systems with a standby MM.
1.3.6.1.4.1.2.3.51.2.4.9.1.4NodeextEthernetInterfaceIPv6
1.3.6.1.4.1.2.3.51.2.4.9.1.4.1ScalarextEthernetInterfaceIPv6Typeread-onlymandatoryThe type of interface.
1.3.6.1.4.1.2.3.51.2.4.9.1.4.2ScalarextEthernetInterfaceIPv6Enabledread-writemandatoryThe current IPv6 enabled or disabled state of this MM. NOTE: If IPv6 address(es) have been configured for one or more interfaces/protocols/services on this MM,…
1.3.6.1.4.1.2.3.51.2.4.9.1.4.5NodeextEthernetInterfaceIPv6Config
1.3.6.1.4.1.2.3.51.2.4.9.1.4.5.1NodeextEthernetInterfaceIPv6LocalAddress
1.3.6.1.4.1.2.3.51.2.4.9.1.4.5.1.1ScalarextEthernetInterfaceIPv6LinkLocalAddressread-onlymandatoryThe IPv6 link local IP address for the ethernet interface. NOTE: If extEthernetInterfaceIPv6Enabled is currently disabled, this object has the value '0:0:0:0:0…
1.3.6.1.4.1.2.3.51.2.4.9.1.4.5.2NodeextEthernetInterfaceIPv6StaticIPConfig
1.3.6.1.4.1.2.3.51.2.4.9.1.4.5.2.1ScalarextEthernetInterfaceIPv6StaticIPConfigEnabledread-writemandatoryThe IPv6 static IP address enabled or disabled state for the ethernet interface.
1.3.6.1.4.1.2.3.51.2.4.9.1.4.5.2.2ScalarextEthernetInterfaceIPv6StaticIPAddressread-writemandatoryThe IPv6 static IP address for the ethernet interface. NOTE: If extEthernetInterfaceIPv6Enabled is currently disabled, this object has the value '0:0:0:0:0:0:0…
1.3.6.1.4.1.2.3.51.2.4.9.1.4.5.2.3ScalarextEthernetInterfaceIPv6StaticIPAddressPrefixLenread-writemandatoryThe IPv6 static IP address prefix length for the ethernet interface. NOTE: If extEthernetInterfaceIPv6Enabled is currently disabled, this object has the value …
1.3.6.1.4.1.2.3.51.2.4.9.1.4.5.2.4ScalarextEthernetInterfaceIPv6StaticIPDefaultRouteread-writemandatoryThe IPv6 static IP address default route for the ethernet interface. NOTE: If extEthernetInterfaceIPv6Enabled is currently disabled, this object has the value …
1.3.6.1.4.1.2.3.51.2.4.9.1.4.5.2.5ScalarextEthernetInterfaceIPv6LinkFloatingAddressread-writemandatoryThe IPv6 floating IP address for the external ethernet interface. NOTE: If extEthernetInterfaceIPv6Enabled is currently disabled, this object has the value '0:…
1.3.6.1.4.1.2.3.51.2.4.9.1.4.5.3NodeextEthernetInterfaceIPv6AutoIPConfig
1.3.6.1.4.1.2.3.51.2.4.9.1.4.5.3.1ScalarextEthernetInterfaceIPv6AutoIPConfigEnabledread-writemandatoryThe IPv6 automatic IP configuration enabled or disabled state for the ethernet interface. NOTE: extEthernetInterfaceIPv6AutoIPConfigEnabled is the logical OR o…
1.3.6.1.4.1.2.3.51.2.4.9.1.4.5.3.2NodeextEthernetInterfaceDHCPv6Config
1.3.6.1.4.1.2.3.51.2.4.9.1.4.5.3.2.1ScalarextEthernetInterfaceDHCPv6Enabledread-writemandatoryThe DHCPv6 enabled or disabled state for the ethernet interface. NOTE: If extEthernetInterfaceIPv6StatelessAutoConfigEnabled is currently disabled, Disabling e…
1.3.6.1.4.1.2.3.51.2.4.9.1.4.5.3.2.2ScalarextEthernetInterfaceDHCPv6IPAddressread-onlymandatoryThe IPv6 address for the ethernet interface, assigned by DHCPv6 server. NOTE: If extEthernetInterfaceIPv6Enabled or extEthernetInterfaceDHCPv6Enabled is disabl…
1.3.6.1.4.1.2.3.51.2.4.9.1.4.5.3.2.4ScalarextEthernetInterfaceDHCPv6DomainNameread-onlymandatoryThe 64 byte Domain Name for the ethernet interface, assigned by the DHCPv6 server. NOTE: If extEthernetInterfaceIPv6Enabled or extEthernetInterfaceDHCPv6Enable…
1.3.6.1.4.1.2.3.51.2.4.9.1.4.5.3.2.5ScalarextEthernetInterfaceDHCPv6PrimaryDNSServerread-onlymandatoryThe primary DNS server, assigned by the DHCPv6 server. NOTE: If extEthernetInterfaceIPv6Enabled or extEthernetInterfaceDHCPv6Enabled is disabled or if DHCPv6 s…
1.3.6.1.4.1.2.3.51.2.4.9.1.4.5.3.2.6ScalarextEthernetInterfaceDHCPv6SecondaryDNSServerread-onlymandatoryThe secondary DNS server, assigned by the DHCPv6 server. NOTE: If extEthernetInterfaceIPv6Enabled or extEthernetInterfaceDHCPv6Enabled is disabled or if DHCPv6…
1.3.6.1.4.1.2.3.51.2.4.9.1.4.5.3.2.7ScalarextEthernetInterfaceDHCPv6TertiaryDNSServerread-onlymandatoryThe tertiary DNS server, assigned by the DHCPv6 server. NOTE: If extEthernetInterfaceIPv6Enabled or extEthernetInterfaceDHCPv6Enabled is disabled or if DHCPv6 …
1.3.6.1.4.1.2.3.51.2.4.9.1.4.5.3.2.8ScalarextEthernetInterfaceDHCPv6Serverread-onlymandatoryThe DHCPv6 server IPv6 address used to acquire the DHCP settings. NOTE: If extEthernetInterfaceIPv6Enabled or extEthernetInterfaceDHCPv6Enabled is disabled or …
1.3.6.1.4.1.2.3.51.2.4.9.1.4.5.3.3NodeextEthernetInterfaceIPv6StatelessAutoConfig
1.3.6.1.4.1.2.3.51.2.4.9.1.4.5.3.3.1ScalarextEthernetInterfaceIPv6StatelessAutoConfigEnabledread-writemandatoryThe IPv6 stateless auto-configuration enabled or disabled state for the ethernet interface. NOTE: If extEthernetfInterfaceDHCPv6Enabled is currently disabled, …
1.3.6.1.4.1.2.3.51.2.4.9.1.4.5.3.3.2TableextEthernetInterfaceStatelessAutoConfigAddressesTablenot-accessiblemandatoryTable of stateless Auto-Config addresses entries
1.3.6.1.4.1.2.3.51.2.4.9.1.4.5.3.3.2.1RowextEthernetInterfaceStatelessAutoConfigAddressesEntrynot-accessiblemandatoryStateless Auto-Config address entries
1.3.6.1.4.1.2.3.51.2.4.9.1.4.5.3.3.2.1.1ColumnextEthernetInterfaceStatelessAutoConfigAddressesIndexread-onlymandatoryIndex for stateless Auto-Config addresses. NOTE: If extEthernetInterfaceIPv6StatelessAutoConfigEnabled or extEthernetInterfaceIPv6Enabled is currently disabled…
1.3.6.1.4.1.2.3.51.2.4.9.1.4.5.3.3.2.1.2ColumnextEthernetInterfaceStatelessAutoConfigAddressesread-onlymandatoryThe stateless Auto-Configuration IPv6 address. NOTE: If extEthernetInterfaceIPv6StatelessAutoConfigEnabled or extEthernetInterfaceIPv6Enabled is currently disa…
1.3.6.1.4.1.2.3.51.2.4.9.1.4.5.3.3.2.1.3ColumnextEthernetInterfaceStatelessAutoConfigAddressesPrefixLenread-onlymandatoryThe stateless Auto-Configration address prefix length. NOTE: If extEthernetInterfaceIPv6StatelessAutoConfigEnabled or extEthernetInterfaceIPv6Enabled is curren…
1.3.6.1.4.1.2.3.51.2.4.9.1.5NodestandbyExtEthernetInterfaceIPv6
1.3.6.1.4.1.2.3.51.2.4.9.1.5.1NodestandbyEthernetInterfaceIPv6LocalAddress
1.3.6.1.4.1.2.3.51.2.4.9.1.5.1.1ScalarstandbyEthernetInterfaceIPv6LinkLocalAddressread-onlymandatoryThe IPv6 link local IP address for the standby MM.
1.3.6.1.4.1.2.3.51.2.4.9.1.5.2NodestandbyEthernetInterfaceIPv6StaticIPConfig
1.3.6.1.4.1.2.3.51.2.4.9.1.5.2.1ScalarstandbyEthernetInterfaceIPv6StaticIPConfigEnabledread-onlymandatoryThe IPv6 static IP address state for the MM. NOTE: This value may be altered through the extEthernetInterfaceIPv6StaticIPConfigEnabled object.
1.3.6.1.4.1.2.3.51.2.4.9.1.5.2.2ScalarstandbyEthernetInterfaceIPv6StaticIPAddressread-writemandatoryThe IPv6 static IP address for the standby MM NOTE: If extEthernetInterfaceIPv6Enabled is currently disabled, this object has the value '0:0:0:0:0:0:0:0'.
1.3.6.1.4.1.2.3.51.2.4.9.1.5.2.3ScalarstandbyEthernetInterfaceIPv6StaticIPAddressPrefixLenread-onlymandatoryThe IPv6 static IP address prefix length for the standyby MM. NOTE: This value may be altered through the extEthernetInterfaceIPv6StaticIPAddressPrefixLen obje…
1.3.6.1.4.1.2.3.51.2.4.9.1.5.2.4ScalarstandbyEthernetInterfaceIPv6StaticIPDefaultRouteread-onlymandatoryThe IPv6 static IP address default route for the standby MM. NOTE: This value may be altered through the extEthernetInterfaceIPv6StaticIPDefaultRoute object.
1.3.6.1.4.1.2.3.51.2.4.9.1.5.3NodestandbyEthernetInterfaceDHCPv6Config
1.3.6.1.4.1.2.3.51.2.4.9.1.5.3.1ScalarstandbyEthernetInterfaceDHCPv6Enabledread-onlymandatoryThe DHCPv6 enabled or disabled state for the standby MM. NOTE: This field may be altered through the extEthernetInterfaceDHCPv6Enabled object.
1.3.6.1.4.1.2.3.51.2.4.9.1.5.3.2ScalarstandbyEthernetInterfaceDHCPv6IPAddressread-onlymandatoryThe IPv6 address for the standby MM assigned by DHCPv6 server.
1.3.6.1.4.1.2.3.51.2.4.9.1.5.3.4ScalarstandbyEthernetInterfaceDHCPv6DomainNameread-onlymandatoryThe 64 byte Domain Name for the standby MM assigned by the DHCPv6 server.
1.3.6.1.4.1.2.3.51.2.4.9.1.5.4TablestandbyEthernetInterfaceStatelessAutoConfigAddressesTablenot-accessiblemandatoryTable of stateless Auto-Config addresses entries. NOTE: If extEthernetInterfaceIPv6StatelessAutoConfigEnabled or extEthernetInterfaceIPv6Enabled is currently d…
1.3.6.1.4.1.2.3.51.2.4.9.1.5.4.1RowstandbyEthernetInterfaceStatelessAutoConfigAddressesEntrynot-accessiblemandatoryStateless Auto-Config address entries
1.3.6.1.4.1.2.3.51.2.4.9.1.5.4.1.1ColumnstandbyEthernetInterfaceStatelessAutoConfigAddressesIndexread-onlymandatoryIndex for stateless Auto-Config addresses.
1.3.6.1.4.1.2.3.51.2.4.9.1.5.4.1.2ColumnstandbyEthernetInterfaceStatelessAutoConfigAddressesread-onlymandatoryThe stateless Auto-Configuration IPv6 address.
1.3.6.1.4.1.2.3.51.2.4.9.1.5.4.1.3ColumnstandbyEthernetInterfaceStatelessAutoConfigAddressesPrefixLenread-onlymandatoryThe stateless Auto-Configration address prefix length.
1.3.6.1.4.1.2.3.51.2.4.9.1.10ScalarddnsStatusread-writemandatoryDynamic DNS provides the capability for a networked device to notify a domain name server to change, in real time, the active DNS configuration of its configur…
1.3.6.1.4.1.2.3.51.2.4.9.1.11ScalarhostNameread-writemandatoryContains the DNS host name for this system. This object provides the exact same function as extEthernetInterfaceHostName
1.3.6.1.4.1.2.3.51.2.4.9.1.12ScalarstandbyHostNameread-writemandatoryContains the DNS host name for the standby. This object provides the exact same function as standbyExtEthernetInterfaceHostName and is only applicable to syste…
1.3.6.1.4.1.2.3.51.2.4.9.1.13ScalardomainNameread-writemandatoryThe user assigned DNS domain name.
1.3.6.1.4.1.2.3.51.2.4.9.1.14ScalarstandbyDomainNameread-writemandatoryThe user assigned DNS domain name of the standby. This is only applicable to systems with a standby MM.
1.3.6.1.4.1.2.3.51.2.4.9.1.16ScalaractivateNetworkUpdatesread-writemandatoryWhen read, the return value indicates if there are any pending network updates ready to be applied. Writing any value will apply any pending network updates im…
1.3.6.1.4.1.2.3.51.2.4.9.1.20NodevlanConfigure
1.3.6.1.4.1.2.3.51.2.4.9.1.20.1ScalarvlanGlobalStateread-writemandatoryThis object disables or enables the VLAN feature. The configuration objects for the VLAN are in the vlanCMMTable. The default setting for this object is disabl…
1.3.6.1.4.1.2.3.51.2.4.9.1.20.2ScalarvlanCommitTimeoutread-writemandatoryThis object is the number of minutes from the last VLAN-related object change until any non-committed changes will revert back to their previous settings. This…
1.3.6.1.4.1.2.3.51.2.4.9.1.20.3ScalarvlanCommitStateread-writemandatoryThis object gives the status of whether there are VLAN-related changes pending that need to be committed, and allows a user to commit (save) any VLAN changes. …
1.3.6.1.4.1.2.3.51.2.4.9.1.20.20TablevlanCMMTablenot-accessiblemandatoryThis table contains the VLAN configuration objects. The default entry has an vlanCMMIndex equal to 1. The objects for this default entry are configurable. An a…
1.3.6.1.4.1.2.3.51.2.4.9.1.20.20.1RowvlanCMMEntrynot-accessiblemandatoryVLAN entries.
1.3.6.1.4.1.2.3.51.2.4.9.1.20.20.1.1ColumnvlanCMMIndexread-onlymandatoryIndex for VLAN entry. If vlanCMMIndex is equal to 1, it is the Default VLAN entry and cannot be deleted.
1.3.6.1.4.1.2.3.51.2.4.9.1.20.20.1.2ColumnvlanCMMVlanIdread-writemandatoryValid VLAN ID. Allowed values are 5..4094. If the entry is not valid, this object will have the value of 0. If this entry has the vlanCMMIndex value of 1 (defa…
1.3.6.1.4.1.2.3.51.2.4.9.1.20.20.1.3ColumnvlanCMMNameread-writemandatoryThis object allows the user to configure a text string name for this VLAN entry. This entry name is only used as a label for this entry.
1.3.6.1.4.1.2.3.51.2.4.9.1.20.20.1.4ColumnvlanCMMEntryStatusread-writemandatoryThis object manages the creation and deletion of this entry. The steps recommended to add a new VLAN entry are: 1. Create a new entry in this table vlanCMMEntr…
1.3.6.1.4.1.2.3.51.2.4.9.1.20.20.1.5ColumnvlanCMMStateread-writemandatoryThis object indicates whether this VLAN entry is enabled or disabled and allows the user to disable, enable or restart this entry except for the exceptions not…
1.3.6.1.4.1.2.3.51.2.4.9.1.20.20.1.6ColumnvlanCMMSOLAccessread-writemandatoryThis object allows the user to set whether the VLAN for this entry will have access to the Serial Over LAN (SOL) interface. Only one VLAN entry may have this o…
1.3.6.1.4.1.2.3.51.2.4.9.1.20.20.1.8ColumnvlanCMMTaggingread-writemandatoryThis object allows the user to set whether VLAN tagging is enabled for this VLAN entry. This object is only configurable for the entry with the vlanCMMIndex va…
1.3.6.1.4.1.2.3.51.2.4.9.1.20.20.1.31ColumnvlanCMMIPv4Addressread-writemandatoryThis object sets the IPv4 address for this VLAN entry. The entry with the vlanCMMIndex value of 1 (default VLAN entry) will have this object set to the IP addr…
1.3.6.1.4.1.2.3.51.2.4.9.1.20.20.1.32ColumnvlanCMMIPv4Gatewayread-writemandatoryThis object sets the IPv4 address for the IP gateway for this VLAN entry. The entry with the vlanCMMIndex value of 1 (default VLAN entry) will have this object…
1.3.6.1.4.1.2.3.51.2.4.9.1.20.20.1.33ColumnvlanCMMIPv4Maskread-writemandatoryThis object sets the IPv4 subnet mask for this VLAN entry. The entry with the vlanCMMIndex value of 1 (default VLAN entry) will have this object set to the sub…
1.3.6.1.4.1.2.3.51.2.4.9.1.20.20.1.51ColumnvlanCMMIPv4SubnetRoute1read-writemandatoryThis object sets the IPv4 address of the subnet route 1 for this VLAN entry. The entry with the vlanCMMIndex value of 1 (default VLAN entry) will always have t…
1.3.6.1.4.1.2.3.51.2.4.9.1.20.20.1.52ColumnvlanCMMIPv4SubnetRouteMask1read-writemandatoryThis object sets the IPv4 subnet route mask 1 for this VLAN entry. The entry with the vlanCMMIndex value of 1 (default VLAN entry) will always have this object…
1.3.6.1.4.1.2.3.51.2.4.9.1.20.20.1.53ColumnvlanCMMIPv4SubnetRoute2read-writemandatoryThis object sets the IPv4 address of the subnet route 2 for VLAN entry. The entry with the vlanCMMIndex value of 1 (default VLAN entry) will always have this o…
1.3.6.1.4.1.2.3.51.2.4.9.1.20.20.1.54ColumnvlanCMMIPv4SubnetRouteMask2read-writemandatoryThis object sets the IPv4 subnet route mask 2 for this VLAN entry. The entry with the vlanCMMIndex value of 1 (default VLAN entry) will always have this object…
1.3.6.1.4.1.2.3.51.2.4.9.1.20.20.1.55ColumnvlanCMMIPv4SubnetRoute3read-writemandatoryThis object sets the IPv4 address of the subnet route 3 for this VLAN entry. The entry with the vlanCMMIndex value of 1 (default VLAN entry) will always have t…
1.3.6.1.4.1.2.3.51.2.4.9.1.20.20.1.56ColumnvlanCMMIPv4SubnetRouteMask3read-writemandatoryThis object sets the IPv4 subnet route mask 3 for this VLAN entry. The entry with the vlanCMMIndex value of 1 (default VLAN entry) will always have this object…
1.3.6.1.4.1.2.3.51.2.4.9.1.20.20.1.71ColumnvlanCMMIPv6Addressread-writemandatoryThis object sets the IPv6 address for this VLAN entry. The entry with the vlanCMMIndex value of 1 (default VLAN entry) will have this object set to the IP addr…
1.3.6.1.4.1.2.3.51.2.4.9.1.20.20.1.72ColumnvlanCMMIPv6AddressPrefixLenread-writemandatoryThis object sets the IPv6 address prefix length for this VLAN entry. The entry with the vlanCMMIndex value of 1 (default VLAN entry) will have this object set …
1.3.6.1.4.1.2.3.51.2.4.9.1.20.20.1.73ColumnvlanCMMIPv6Gatewayread-writemandatoryThis object sets the IPv6 address for the IP gateway for this VLAN entry. The entry with the vlanCMMIndex value of 1 (default VLAN entry) will have this object…
1.3.6.1.4.1.2.3.51.2.4.9.1.20.20.1.91ColumnvlanCMMIPv6SubnetRoute1read-writemandatoryThis object sets the IPv6 address of the subnet route 1 for this VLAN entry. The entry with the vlanCMMIndex value of 1 (default VLAN entry) will always have t…
1.3.6.1.4.1.2.3.51.2.4.9.1.20.20.1.92ColumnvlanCMMIPv6SubnetRoutePrefixLen1read-writemandatoryThis object sets the IPv6 address prefix length of the subnet route 1 for this VLAN entry. The entry with the vlanCMMIndex value of 1 (default VLAN entry) will…
1.3.6.1.4.1.2.3.51.2.4.9.1.20.20.1.93ColumnvlanCMMIPv6SubnetRoute2read-writemandatoryThis object sets the IPv6 address of the subnet route 2 for this VLAN entry. The entry with the vlanCMMIndex value of 1 (default VLAN entry) will always have t…
1.3.6.1.4.1.2.3.51.2.4.9.1.20.20.1.94ColumnvlanCMMIPv6SubnetRoutePrefixLen2read-writemandatoryThis object sets the IPv6 address prefix length of the subnet route 2 for this VLAN entry. The entry with the vlanCMMIndex value of 1 (default VLAN entry) will…
1.3.6.1.4.1.2.3.51.2.4.9.1.20.20.1.95ColumnvlanCMMIPv6SubnetRoute3read-writemandatoryThis object sets the IPv6 address of the subnet route 3 for this VLAN entry. The entry with the vlanCMMIndex value of 1 (default VLAN entry) will always have t…
1.3.6.1.4.1.2.3.51.2.4.9.1.20.20.1.96ColumnvlanCMMIPv6SubnetRoutePrefixLen3read-writemandatoryThis object sets the IPv6 address prefix length of the subnet route 3 for this VLAN entry. The entry with the vlanCMMIndex value of 1 (default VLAN entry) will…
1.3.6.1.4.1.2.3.51.2.4.9.1.20.21ScalarvlanCMMTableCacheTimeoutread-onlymandatoryThe timeout value (in seconds) of the cached data for the table, vlanCMMTable. This value is static (constant) and cannot be set.
1.3.6.1.4.1.2.3.51.2.4.9.3NodetcpProtocols
1.3.6.1.4.1.2.3.51.2.4.9.3.1NodesnmpAgentConfig
1.3.6.1.4.1.2.3.51.2.4.9.3.1.1ScalarsnmpSystemContactread-writemandatoryA NULL terminated 48 byte string that contains the SNMP agent contact name.
1.3.6.1.4.1.2.3.51.2.4.9.3.1.2ScalarsnmpSystemLocationread-writemandatoryA NULL terminated 48 byte string that contains the SNMP agent location name.
1.3.6.1.4.1.2.3.51.2.4.9.3.1.3ScalarsnmpSystemAgentTrapsDisableread-writemandatoryDisable or enable SNMP traps.
1.3.6.1.4.1.2.3.51.2.4.9.3.1.4NodesnmpAgentCommunityConfig
1.3.6.1.4.1.2.3.51.2.4.9.3.1.4.1TablesnmpCommunityTablenot-accessiblemandatoryTable of SNMP Community entries
1.3.6.1.4.1.2.3.51.2.4.9.3.1.4.1.1RowsnmpCommunityEntrynot-accessiblemandatorySNMP community entries
1.3.6.1.4.1.2.3.51.2.4.9.3.1.4.1.1.1ColumnsnmpCommunityEntryIndexread-onlymandatoryIndex for SNMP Agent Community entry.
1.3.6.1.4.1.2.3.51.2.4.9.3.1.4.1.1.2ColumnsnmpCommunityEntryCommunityNameread-writemandatorySNMP Community entry name.
1.3.6.1.4.1.2.3.51.2.4.9.3.1.4.1.1.3ColumnsnmpCommunityEntryCommunityIpAddress1read-writemandatorySNMP Community IP address or host name. Can either be a dotted decimal IP string (e.g. 9.37.44.2) or if DNS is enabled a host name. This field also allows two …
1.3.6.1.4.1.2.3.51.2.4.9.3.1.4.1.1.4ColumnsnmpCommunityEntryCommunityIpAddress2read-writemandatorySNMP Community IP address or host name. Can either be a dotted decimal IP string (e.g. 9.37.44.2) or if DNS is enabled a host name. This field also allows two …
1.3.6.1.4.1.2.3.51.2.4.9.3.1.4.1.1.5ColumnsnmpCommunityEntryCommunityIpAddress3read-writemandatorySNMP Community IP address or host name. Can either be a dotted decimal IP string (e.g. 9.37.44.2) or if DNS is enabled a host name. This field also allows two …
1.3.6.1.4.1.2.3.51.2.4.9.3.1.4.1.1.6ColumnsnmpCommunityEntryCommunityViewTyperead-writemandatoryAccess Level of the SNMPv1 managers. Note this parameter is set for each community. Therefore all three managers in the same community have the same access lev…
1.3.6.1.4.1.2.3.51.2.4.9.3.1.5Scalarsnmpv1SystemAgentEnableread-writemandatoryDisable or enable the SNMPv1 agent. NOTE: Restart the management module if this MIB object is changed with respect to the value at system bootup time. For exam…
1.3.6.1.4.1.2.3.51.2.4.9.3.1.6Scalarsnmpv3SystemAgentEnableread-writemandatoryDisable or enable the SNMPv3 agent. NOTE: Restart the management module if this MIB object is changed with respect to the value at system bootup time. For exam…
1.3.6.1.4.1.2.3.51.2.4.9.3.1.9NodesnmpAgentUserProfileConfig
1.3.6.1.4.1.2.3.51.2.4.9.3.1.9.1TablesnmpUserProfileTablenot-accessiblemandatoryTable of SNMPv3 User Profile entries
1.3.6.1.4.1.2.3.51.2.4.9.3.1.9.1.1RowsnmpUserProfileEntrynot-accessiblemandatorySNMP User Profile entries
1.3.6.1.4.1.2.3.51.2.4.9.3.1.9.1.1.1ColumnsnmpUserProfileEntryIndexread-onlymandatoryIndex for SNMPv3 Agent User Profile entry.
1.3.6.1.4.1.2.3.51.2.4.9.3.1.9.1.1.3ColumnsnmpUserProfileEntryContextNameread-writemandatorySNMPv3 User Profile entry - Context name for users to access MIB objects. Note that context names can be duplicates and can be shared among users. Empty contex…
1.3.6.1.4.1.2.3.51.2.4.9.3.1.9.1.1.4ColumnsnmpUserProfileEntryAuthProtread-writemandatorySNMPv3 User Profile entry - Authentication Protocol supported by the user.
1.3.6.1.4.1.2.3.51.2.4.9.3.1.9.1.1.6ColumnsnmpUserProfileEntryPrivProtread-writemandatorySNMPv3 User Profile entry - Privacy Protocol supported by the user. The Privacy Password must be set and the Authentication Protocol must be md5 or sha before …
1.3.6.1.4.1.2.3.51.2.4.9.3.1.9.1.1.7ColumnsnmpUserProfileEntryPrivPasswordread-writemandatorySNMPv3 User Profile entry - Privacy password for the user. NOTE: Value returned for the GET command is meaningless for this MIB object for security reasons.
1.3.6.1.4.1.2.3.51.2.4.9.3.1.9.1.1.8ColumnsnmpUserProfileEntryViewTyperead-writemandatorySNMPv3 User Profile entry - Access level (Get, Set, and Traps) of the user.
1.3.6.1.4.1.2.3.51.2.4.9.3.1.9.1.1.9ColumnsnmpUserProfileEntryIpAddressread-writemandatorySNMPv3 User Profile entry - IP address or host name. Can either be a dotted decimal IP string (e.g. 9.37.44.2) or if DNS is enabled a host name.
1.3.6.1.4.1.2.3.51.2.4.9.3.1.9.1.1.10ColumnsnmpUserProfileEntryUserIdread-onlymandatoryThe userid for the SNMPv3 Agent User Profile entry.
1.3.6.1.4.1.2.3.51.2.4.9.3.2NodednsConfig
1.3.6.1.4.1.2.3.51.2.4.9.3.2.1ScalardnsEnabledread-writemandatoryDisable or enable the DNS agent. NOTE: To alter any of the configuration settings for the DNS agent, the following procedure should be used: (1) This object sh…
1.3.6.1.4.1.2.3.51.2.4.9.3.2.2ScalardnsServerIPAddress1read-writemandatoryContains the primary DNS server IP address.
1.3.6.1.4.1.2.3.51.2.4.9.3.2.3ScalardnsServerIPAddress2read-writemandatoryContains the secondary DNS server IP address.
1.3.6.1.4.1.2.3.51.2.4.9.3.2.4ScalardnsServerIPAddress3read-writemandatoryContains the tertiary DNS server IP address.
1.3.6.1.4.1.2.3.51.2.4.9.3.2.12ScalardnsServerIPv6Address1read-writemandatoryContains the primary IPv6 DNS server address.
1.3.6.1.4.1.2.3.51.2.4.9.3.2.13ScalardnsServerIPv6Address2read-writemandatoryContains the secondary IPv6 DNS server address.
1.3.6.1.4.1.2.3.51.2.4.9.3.2.14ScalardnsServerIPv6Address3read-writemandatoryContains the tertiary IPv6 DNS server address.
1.3.6.1.4.1.2.3.51.2.4.9.3.2.20ScalardnsPriorityread-writemandatoryTells the order host names are resolved. The options are to either first resolve with an IPv6 DNS server or to first resolve with an IPv6 DNS server.
1.3.6.1.4.1.2.3.51.2.4.9.3.3NodesmtpConfig
1.3.6.1.4.1.2.3.51.2.4.9.3.3.1ScalarsmtpServerNameOrIPAddressread-writemandatoryA NULL terminated 64 byte string that contains the SMTP server host name or IP address (a.b.c.d).
1.3.6.1.4.1.2.3.51.2.4.9.3.3.2ScalarattachmentsToEmailAlertsread-writemandatoryIndicates if the service information should be attached to an email alert.
1.3.6.1.4.1.2.3.51.2.4.9.3.3.3ScalarsmtpEmailDomainread-writemandatoryA NULL terminated string that contains the SMTP email domain. If this field is empty, the MM IP address is used as the domain. However, some SMTP servers (e.g.…
1.3.6.1.4.1.2.3.51.2.4.9.3.4NodetcpApplicationConfig
1.3.6.1.4.1.2.3.51.2.4.9.3.4.1ScalartelnetInactivityTimeoutread-writemandatoryDefault is 120 seconds. Value of zero is no timeout. Max value is any positive 4 bytes value. Note that SSH also uses this timeout value to wait before disconn…
1.3.6.1.4.1.2.3.51.2.4.9.3.4.2ScalarcommandModeInactivityTimeoutread-writemandatoryThe amount of time in seconds before the (Secure)TCP Command Mode times out. Default value of 0 means no timeout. Max value is any positive 4 byte value.
1.3.6.1.4.1.2.3.51.2.4.9.3.4.3ScalarsecureCommandModeEnableread-writemandatorySet Secure TCP Command Mode number of connections. MM will provide a max of 20 connections for both Secure TCP Command Mode and TCP Command Mode. A value of 0 …
1.3.6.1.4.1.2.3.51.2.4.9.3.4.4ScalarcommandModeEnableread-writemandatorySet TCP Command Mode number of connections. MM will provide a max of 20 connections for both Secure TCP Command Mode and TCP Command Mode. A value of 0 means d…
1.3.6.1.4.1.2.3.51.2.4.9.3.4.5ScalarslpAddrTyperead-writemandatorySet SLP address type to 0 (multicast) or 1 (broadcast). Note that when slpAddrType is set to broadcast value then the multicast address set in slpMulticastAddr…
1.3.6.1.4.1.2.3.51.2.4.9.3.4.7ScalarslpEnableread-writemandatoryDisable/Enable Service Location Protocol. NOTE: Change to Service Location Protocol will take effect after the next restart of the MM.
1.3.6.1.4.1.2.3.51.2.4.9.3.4.9ScalartelnetEnableread-writemandatoryDisable/Enable telnet. NOTE: Change to telnet enable/disable will take effect immediately.
1.3.6.1.4.1.2.3.51.2.4.9.3.4.10ScalarsshEnableread-writemandatoryDisable/Enable SSH.
1.3.6.1.4.1.2.3.51.2.4.9.3.4.15ScalarsslServerEnableread-writemandatoryDisable/Enable SSL Server.
1.3.6.1.4.1.2.3.51.2.4.9.3.4.16ScalarsslClientEnableread-writemandatoryDisable/Enable SSL Client. If no valid client or server certificate is in place, SSL client will not be allowed to set to enable.
1.3.6.1.4.1.2.3.51.2.4.9.3.4.17ScalarftpEnableread-writemandatoryDisable/Enable FTP.
1.3.6.1.4.1.2.3.51.2.4.9.3.4.18ScalarsftpEnableread-writemandatoryDisable/Enable SFTP.
1.3.6.1.4.1.2.3.51.2.4.9.3.4.19ScalartftpEnableread-writemandatoryDisable/Enable TFTP.
1.3.6.1.4.1.2.3.51.2.4.9.3.4.23ScalarftpTimeoutread-writemandatoryThe amount of time before FTP times out. Default is 300 seconds. Value of zero is no timeout. Max value is any positive 4 byte value.
1.3.6.1.4.1.2.3.51.2.4.9.3.4.27NodemmSshServerConfig
1.3.6.1.4.1.2.3.51.2.4.9.3.4.27.1TablemmSshServerHostKeyTablenot-accessiblemandatoryA table that contains per public/private host key pair information.
1.3.6.1.4.1.2.3.51.2.4.9.3.4.27.1.1RowmmSshServerHostKeyEntrynot-accessiblemandatoryA list of information about a particular public/private host key pair.
1.3.6.1.4.1.2.3.51.2.4.9.3.4.27.1.1.1ColumnmmSshServerHostKeyIndexread-onlymandatoryThe index of the public/private host key pair.
1.3.6.1.4.1.2.3.51.2.4.9.3.4.27.1.1.2ColumnmmSshServerHostKeyTyperead-onlymandatoryThe type of the public/private host key pair.
1.3.6.1.4.1.2.3.51.2.4.9.3.4.27.1.1.3ColumnmmSshServerHostKeySizeread-onlymandatoryThe size of the public/private host key pair. NOTE: The MM supports only the bits2048 value.
1.3.6.1.4.1.2.3.51.2.4.9.3.4.27.1.1.4ColumnmmSshServerHostKeyFingerprintread-onlymandatoryThe RSA fingerprint of the public part of the host key pair. This value can be used with the SSH client to verify, on the initial connection, that the Secure S…
1.3.6.1.4.1.2.3.51.2.4.9.3.4.27.2ScalarmmSshServerHostKeyGenerateread-writemandatoryInitiate the new Host Keys generation process for the MM SSH Server. NOTE: Value returned for the GET command is meaningless for this MIB object.
1.3.6.1.4.1.2.3.51.2.4.9.3.4.27.3ScalarmmSshServerHostKeyGenerateProgressread-onlymandatoryIndicate the progress of the key generation process.
1.3.6.1.4.1.2.3.51.2.4.9.3.4.50ScalarcimEnableread-writemandatoryDisable/Enable CIM (Common Information Model) interface. NOTE: Change to CIM enable/disable will take effect immediately.
1.3.6.1.4.1.2.3.51.2.4.9.3.5NodetcpPortAssignmentCfg
1.3.6.1.4.1.2.3.51.2.4.9.3.5.1ScalartcpPortsRestoreDefaultread-writemandatoryReset all ports to default value. http: 80 https: 443 telnet: 23 ssh: 22 SNMP agent: 161 SNMP trap: 162 TCP Command Mode: 6090 Secure TCP Command Mode: 6091 FT…
1.3.6.1.4.1.2.3.51.2.4.9.3.5.2ScalarhttpPortAssignmentread-writemandatoryHTTP port number. Default value is 80. Once changed, the URL's have to include :port at the end.
1.3.6.1.4.1.2.3.51.2.4.9.3.5.3ScalarhttpsPortAssignmentread-writemandatorySSL port number. Default value is 443. Once changed, the URL's have to include :port at the end.
1.3.6.1.4.1.2.3.51.2.4.9.3.5.4ScalartelnetPortAssignmentread-writemandatoryTelnet port number. Default value is 23. Port change will take effect immediately.
1.3.6.1.4.1.2.3.51.2.4.9.3.5.5ScalarsshPortAssignmentread-writemandatorySSH port number. Default value is 22.
1.3.6.1.4.1.2.3.51.2.4.9.3.5.6ScalarsnmpAgentPortAssignmentread-writemandatorySNMP Agent port number. Default value is 161. Changes take effect after several seconds.
1.3.6.1.4.1.2.3.51.2.4.9.3.5.7ScalarsnmpTrapsPortAssignmentread-writemandatorySNMP Traps port number. Default value is 162. Changes take effect after several seconds.
1.3.6.1.4.1.2.3.51.2.4.9.3.5.8ScalarcommandModePortAssignmentread-writemandatoryTCP Command Mode port number. Default value is 6090. Change will take effect immediately.
1.3.6.1.4.1.2.3.51.2.4.9.3.5.9ScalarsecureCommandModePortAssignmentread-writemandatorySecure TCP Command Mode port number. Default value is 6091. Change will take effect immediately.
1.3.6.1.4.1.2.3.51.2.4.9.3.5.13ScalarftpPortAssignmentread-writemandatoryFTP port number. Default value is 21. Port change will take effect immediately.
1.3.6.1.4.1.2.3.51.2.4.9.3.5.14ScalarftpDataPortAssignmentread-writemandatoryFTP Data port number. Default value is 20. Port change will take effect immediately.
1.3.6.1.4.1.2.3.51.2.4.9.3.5.15ScalartftpPortAssignmentread-writemandatoryTFTP port number. Default value is 69.
1.3.6.1.4.1.2.3.51.2.4.9.3.5.19ScalarslpPortAssignmentread-writemandatoryService Location Protocol port number. Default value is 427. NOTE: This value is normally required to be 427 to interoperate properly with other SLP enabled ap…
1.3.6.1.4.1.2.3.51.2.4.9.3.5.50ScalarcimPortAssignmentread-writemandatoryCIM (Common Information Model) port number. Default value is 5989. Port change will take effect immediately.
1.3.6.1.4.1.2.3.51.2.4.9.3.6NodeldapClientCfg
1.3.6.1.4.1.2.3.51.2.4.9.3.6.1ScalarldapServer1NameOrIPAddressread-writemandatoryA NULL terminated 255 byte string that contains the LDAP server host name or IP address (a.b.c.d).
1.3.6.1.4.1.2.3.51.2.4.9.3.6.2ScalarldapServer1PortNumberread-writemandatoryLDAP server port number.
1.3.6.1.4.1.2.3.51.2.4.9.3.6.3ScalarldapServer2NameOrIPAddressread-writemandatoryA NULL terminated 255 byte string that contains the LDAP server host name or IP address (a.b.c.d).
1.3.6.1.4.1.2.3.51.2.4.9.3.6.4ScalarldapServer2PortNumberread-writemandatoryLDAP server port number.
1.3.6.1.4.1.2.3.51.2.4.9.3.6.5ScalarldapServer3NameOrIPAddressread-writemandatoryA NULL terminated 255 byte string that contains the LDAP server host name or IP address (a.b.c.d).
1.3.6.1.4.1.2.3.51.2.4.9.3.6.6ScalarldapServer3PortNumberread-writemandatoryLDAP server port number.
1.3.6.1.4.1.2.3.51.2.4.9.3.6.7ScalarldapRootDNread-writemandatoryA NULL terminated 255 byte string that contains the distinguished Name for root entry of directory tree. An example might look like dn=foobar,dn=com.
1.3.6.1.4.1.2.3.51.2.4.9.3.6.9ScalarldapGroupFilterread-writemandatoryThis filter is used for group authentication. It specifies what group or groups that this MM belongs to. If left blank, group authentication is disabled. Other…
1.3.6.1.4.1.2.3.51.2.4.9.3.6.10ScalarldapBindingMethodread-writemandatoryOn initial binds to the LDAP server during user authentication, there are two options: Client authentication: Bind attempt is made with client DN and password …
1.3.6.1.4.1.2.3.51.2.4.9.3.6.11ScalarldapClientAuthenticationDNread-writemandatoryThe initial bind to the LDAP server during user authentication can be performed with anonymous authentication, client based authentication, or UPN. The client …
1.3.6.1.4.1.2.3.51.2.4.9.3.6.12ScalarldapClientAuthenticationPasswordread-writemandatoryThe client authentication password
1.3.6.1.4.1.2.3.51.2.4.9.3.6.13ScalarldapUIDsearchAttributeread-writemandatoryWhen the binding method selected is Anonymous authentication or Client authentication, the initial bind to the LDAP server is followed by a search request aime…
1.3.6.1.4.1.2.3.51.2.4.9.3.6.14ScalarldapGroupSearchAttributeread-writemandatoryWhen the MM Group Filter name is configured, it is necessary to retrieve from the LDAP server the list of groups that a particular user belongs to. This is req…
1.3.6.1.4.1.2.3.51.2.4.9.3.6.15ScalarldapLoginPermissionAttributeread-writemandatoryWhen a user successfully authenticates via a LDAP server, it is necessary to retrieve the login permissions for this user. In order to retrieve these permissio…
1.3.6.1.4.1.2.3.51.2.4.9.3.6.16ScalarldapUseDNSOrPreConfiguredServersread-writemandatoryThe MM contains a Version 2.0 LDAP Client that may be configured to provide user authentication through one or more LDAP servers. The LDAP server(s) to be used…
1.3.6.1.4.1.2.3.51.2.4.9.3.6.20ScalarldapRBSModelCfgread-writemandatoryThere are two mechanisms to authenticate and authorize users on the MM when using an LDAP-enabled server. The first mechanism (oldPermissionString), also known…
1.3.6.1.4.1.2.3.51.2.4.9.3.6.21ScalarldapTargetNameread-writemandatoryWhen administrator chooses Enhanced Role Based Security authentication model, he can associate one MM with one managed target object in Snap-in (one tool to co…
1.3.6.1.4.1.2.3.51.2.4.9.3.6.22ScalarldapAuthCfgread-writemandatoryIf ldapAuthCfg is set to 0, LDAP server is used to authenticate and authorize users. If it is set to 1, LDAP server is only used to authenticate users. Note:LD…
1.3.6.1.4.1.2.3.51.2.4.9.3.6.23ScalarldapForestNameread-writemandatoryLDAP Forest Name. Note: LDAP Forest Name is only for Active Directory environment.
1.3.6.1.4.1.2.3.51.2.4.9.3.6.24ScalarldapDomainNameread-writemandatoryA NULL terminated 255 byte string that contains the LDAP Domain Name.
1.3.6.1.4.1.2.3.51.2.4.9.3.6.25ScalarldapServer4NameOrIPAddressread-writemandatoryA NULL terminated 255 byte string that contains the LDAP server host name or IP address (a.b.c.d).
1.3.6.1.4.1.2.3.51.2.4.9.3.6.26ScalarldapServer4PortNumberread-writemandatoryLDAP server port number.
1.3.6.1.4.1.2.3.51.2.4.9.3.7NodeuplinkCheckConfig
1.3.6.1.4.1.2.3.51.2.4.9.3.7.1ScalaruplinkCheckEnabledread-writemandatoryDisable or enable network uplink checking for physical detection. NOTE: This MIB object is only applicable to systems with a standby MM.
1.3.6.1.4.1.2.3.51.2.4.9.3.7.2ScalaruplinkCheckDelayread-writemandatoryDelay, in minutes (1-2880), between discovery of a failed network uplink and the subsequent MM failover for physical detection. NOTE: This MIB object is only a…
1.3.6.1.4.1.2.3.51.2.4.9.3.7.3ScalarlogicalUplinkDestinationread-writemandatoryDestination IP for MM to check its logical link. Specify a non-zero IP Address in order to enable logical uplink checking. NOTE: This MIB object is only applic…
1.3.6.1.4.1.2.3.51.2.4.9.3.7.4ScalarlogicalUplinkCheckEnabledread-writemandatoryDisable or enable network uplink checking for logical detection. logicalUplinkDestination must be set to a non-zero IP Address before enable logical uplink che…
1.3.6.1.4.1.2.3.51.2.4.9.3.7.5ScalarlogicalUplinkCheckDelayread-writemandatoryDelay, in minutes(1-2880), between discovery of a failed network uplink and the subsequent MM failover for logical detection. NOTE: This MIB object is only app…
1.3.6.1.4.1.2.3.51.2.4.9.3.7.6ScalarphysicalUplinkCheckDelayInSecsread-writemandatoryDelay, in seconds(10-172800), between discovery of a failed network uplink and the subsequent MM failover for physical detection. NOTE: This MIB object is only…
1.3.6.1.4.1.2.3.51.2.4.9.3.7.7ScalarlogicalUplinkCheckDelayInSecsread-writemandatoryDelay, in seconds(60-172800), between discovery of a failed network uplink and the subsequent MM failover for logical detection. NOTE: This MIB object is only …
1.3.6.1.4.1.2.3.51.2.4.9.3.7.8ScalarlogicalUplinkIPv6Destinationread-writemandatoryDestination IP for MM to check its logical link using IPv6. Specify a non-zero IP Address in order to enable logical uplink checking. NOTE: This MIB object is …
1.3.6.1.4.1.2.3.51.2.4.9.3.7.9ScalarlogicalUplinkFailoverPolicyread-writemandatoryDetermines when to failover if both an IPv4 and IPv6 destination have been configured. If set to 'either' the system will failover if either of the destination…
1.3.6.1.4.1.2.3.51.2.4.9.3.8NodentpConfig
1.3.6.1.4.1.2.3.51.2.4.9.3.8.1ScalarntpEnableread-writemandatoryDisable/Enable the NTP client. The client will update the MM system clock at the frequency specified.
1.3.6.1.4.1.2.3.51.2.4.9.3.8.2ScalarntpIpAddressHostnameread-writemandatoryNTP server's IP address or hostname if DNS is enabled and configured.
1.3.6.1.4.1.2.3.51.2.4.9.3.8.3ScalarntpUpdateFrequencyread-writemandatoryThe frequency in minutes that the NTP service runs. The value range is 0 to 45000. If the NTP update frequency is set to 0, the MM clock can only be synchroniz…
1.3.6.1.4.1.2.3.51.2.4.9.3.8.4ScalarntpLastUpdateread-onlymandatoryThe date and time that the NTP server last updated the system clock.
1.3.6.1.4.1.2.3.51.2.4.9.3.8.5ScalarntpUpdateClockread-writemandatoryUpdate the MM system clock with the specified NTP server. A valid NTP server must be configured first.
1.3.6.1.4.1.2.3.51.2.4.9.3.8.6ScalarntpAuthEntryread-writemandatoryThe NTP v3 authentication entry to be used for time sync with a secure NTP server. The format of an authentication entry is <key index> <key type> <key>. <key …
1.3.6.1.4.1.2.3.51.2.4.9.3.8.7ScalarntpAuthEnableread-writemandatoryEnables/Disables NTP v3 authentication
1.3.6.1.4.1.2.3.51.2.4.9.3.9NodesyslogConfig
1.3.6.1.4.1.2.3.51.2.4.9.3.9.1ScalarsyslogSevFilterLevelread-writemandatorysyslogSevFilterLevel error/warning/information .
1.3.6.1.4.1.2.3.51.2.4.9.3.9.2NodesyslogCollectorConfig
1.3.6.1.4.1.2.3.51.2.4.9.3.9.2.1TablesyslogCollectorTablenot-accessiblemandatoryTable of Syslog Collector entries
1.3.6.1.4.1.2.3.51.2.4.9.3.9.2.1.1RowsyslogCollectorEntrynot-accessiblemandatorySyslog Collector entries
1.3.6.1.4.1.2.3.51.2.4.9.3.9.2.1.1.1ColumnsyslogCollectorIndexread-onlymandatoryIndex for Syslog Collector entry.
1.3.6.1.4.1.2.3.51.2.4.9.3.9.2.1.1.2ColumnsyslogCollectorHostnameOrIpAddressread-writemandatorySyslog Collector IP address or host name.
1.3.6.1.4.1.2.3.51.2.4.9.3.9.2.1.1.3ColumnsyslogCollectorPortread-writemandatorySyslog Collector port number.
1.3.6.1.4.1.2.3.51.2.4.9.3.9.2.1.1.4ColumnsyslogCollectorEnableread-writemandatorySyslog Collector enable/disable.
1.3.6.1.4.1.2.3.51.2.4.9.3.9.3ScalarsyslogTestPacketread-writemandatoryGenerate a test syslog packet. This will send a test syslog to all configured and enabled syslog collectors to assist in validating the configuration. NOTE: Va…
1.3.6.1.4.1.2.3.51.2.4.10NodesolConfiguration
1.3.6.1.4.1.2.3.51.2.4.10.1NodesolGlobalConfig
1.3.6.1.4.1.2.3.51.2.4.10.1.1ScalarsolEnableread-writemandatoryDisable/Enable SOL dynamically.
1.3.6.1.4.1.2.3.51.2.4.10.1.3ScalarsolAccumulateTimeoutread-writemandatoryThis value specifies how much time in millisecond SOL to buffer data before sending the next SOL packet since the last SOL packet was transmitted. Valid value …
1.3.6.1.4.1.2.3.51.2.4.10.1.4ScalarsolCharSendThresholdread-writemandatoryThis value specifies how many characters SOL to buffer before sending the next SOL packet since the last SOL packet was transmitted. Valid value is from 1 to 2…
1.3.6.1.4.1.2.3.51.2.4.10.1.5ScalarsolRetryread-writemandatoryRetry count. Valid value from 0-7. 0 means no retries after packet is transmitted. Packet will be dropped if no ACK/NACK received by the time retries expired.
1.3.6.1.4.1.2.3.51.2.4.10.1.6ScalarsolRetryIntervalread-writemandatoryRetry Interval in 10 ms increment. Sets the time that the SOL will wait before the first retry and the time between retries when sending SOL packets to the rem…
1.3.6.1.4.1.2.3.51.2.4.10.1.7ScalarsolExitToCliKeySeqread-writemandatoryThis is the keystroke sequence used to escape out of SOL session and back to CLI console. This sequence must have at least one character. The caret symbol (^) …
1.3.6.1.4.1.2.3.51.2.4.10.1.8ScalarsolResetBladeKeySeqread-writemandatoryThis is the keystroke sequence used to reset the blade while in SOL session console. This sequence must have at least one character. The caret symbol (^) has a…
1.3.6.1.4.1.2.3.51.2.4.10.2NodesolBladeConfig
1.3.6.1.4.1.2.3.51.2.4.10.2.1TablesolBladeTablenot-accessiblemandatorySOL Blade configuration table.
1.3.6.1.4.1.2.3.51.2.4.10.2.1.1RowsolBladeEntrynot-accessiblemandatorySOL Blade table entry
1.3.6.1.4.1.2.3.51.2.4.10.2.1.1.1ColumnsolBladeIndexread-onlymandatorySOL Blade table index.
1.3.6.1.4.1.2.3.51.2.4.10.2.1.1.2ColumnsolBladeNameread-onlymandatoryThe name of the blade as a null terminated string.
1.3.6.1.4.1.2.3.51.2.4.10.2.1.1.3ColumnsolBladeEnableread-writemandatoryDisable or enable a SOL on a blade.
1.3.6.1.4.1.2.3.51.2.4.10.2.1.1.4ColumnsolBladeIpAddrread-onlydeprecatedThis is deprecated in favor of solBladeIpAddr6. IP address of the blade derived from the IP address range for the blade system management processors on the bla…
1.3.6.1.4.1.2.3.51.2.4.10.2.1.1.5ColumnsolBladeSessionStatusread-onlymandatoryStatus of a blade SOL session: solSessionNotReady: no SOL session connected to the blade. solSessionReady: there is an SOL session to the blade. solSessionActi…
1.3.6.1.4.1.2.3.51.2.4.10.2.1.1.6ColumnsolBladeCapabilityread-onlymandatoryDisplay whether or not the blade support SOL feature.
1.3.6.1.4.1.2.3.51.2.4.10.2.1.1.7ColumnsolBladeIpAddr6read-onlymandatoryIPv6 address of the blade.
1.3.6.1.4.1.2.3.51.2.4.10.2.1.1.8ColumnsolBladeRetryIntervalread-onlymandatoryRetry interval time in miliseconds.
1.3.6.1.4.1.2.3.51.2.4.10.2.1.1.9ColumnsolBladeRetryCountread-onlymandatoryRetry count.
1.3.6.1.4.1.2.3.51.2.4.10.2.1.1.10ColumnsolBladeBytesSentread-onlymandatoryNumber of bytes sent.
1.3.6.1.4.1.2.3.51.2.4.10.2.1.1.11ColumnsolBladeBytesReceivedread-onlymandatoryNumber of bytes received.
1.3.6.1.4.1.2.3.51.2.4.10.2.1.1.12ColumnsolBladeDestinationMACread-onlymandatoryMAC address of the blade.
1.3.6.1.4.1.2.3.51.2.4.10.2.1.1.13ColumnsolBladeConsoleUserIdread-onlymandatorySol console user name.
1.3.6.1.4.1.2.3.51.2.4.10.2.1.1.14ColumnsolBladeConsoleLoginFromread-onlymandatoryThe location information from where the SOL console is logged in.
1.3.6.1.4.1.2.3.51.2.4.10.2.1.1.15ColumnsolBladeConsoleLoginStartread-onlymandatoryThe time that SOL console starts.
1.3.6.1.4.1.2.3.51.2.4.10.2.1.1.16ColumnsolBladeConsoleLoginEndread-onlymandatoryThe time that SOL console ends.
1.3.6.1.4.1.2.3.51.2.4.11NodechassisInternalNetwork
1.3.6.1.4.1.2.3.51.2.4.11.1ScalarcinsSupportedread-onlymandatoryNumber of Chassis Internal Network (CIN) definitions supported. Currently a maximum of 14 CIN definitions can be supported.
1.3.6.1.4.1.2.3.51.2.4.11.2ScalarcinGlobalEnableread-writemandatoryDisable/Enable Chassis Internal Network (CIN) function dynamically. Enabled: MM reads the CIN entries. For each enabled entry, - If the CIN VLAN ID is new and …
1.3.6.1.4.1.2.3.51.2.4.11.3TablecinTablenot-accessiblemandatoryChassis Internal Network (CIN) configuration table.
1.3.6.1.4.1.2.3.51.2.4.11.3.1RowcinEntrynot-accessiblemandatoryChassis Internal Network (CIN) table entry.
1.3.6.1.4.1.2.3.51.2.4.11.3.1.1ColumncinIndexread-onlymandatoryChassis Internal Network (CIN) table index.
1.3.6.1.4.1.2.3.51.2.4.11.3.1.2ColumncinDefExistsread-onlymandatoryIndicates if a Chassis Internal Network (CIN) definition exists for this index or not.
1.3.6.1.4.1.2.3.51.2.4.11.3.1.3ColumncinDeleteread-writemandatoryDelete Chassis Internal Network (CIN) definition. Works like CIN entry disabled. However, the entry is also deleted. NOTE: Value returned for the GET command i…
1.3.6.1.4.1.2.3.51.2.4.11.3.1.4ColumncinEnableread-writemandatoryDisable or enable a Chassis Internal Network (CIN) definition. Enabled: MM reads the entry and creates a new CIN interface if the CIN VLAN ID is new and does n…
1.3.6.1.4.1.2.3.51.2.4.11.3.1.5ColumncinIdread-writemandatoryThis is the Chassis Internal Network (CIN) Virtual LAN (VLAN) ID for the internal management network between the Management Module, I/O Module, and the blade O…
1.3.6.1.4.1.2.3.51.2.4.11.3.1.6ColumncinIpAddressread-writemandatoryChassis Internal Network (CIN) IP address. Restrictions: - CIN entries cannot have matching IP addresses, with the exception of 0.0.0.0. - Multiple IP addresse…
1.3.6.1.4.1.2.3.51.2.4.11.3.1.7ColumncinIpv6Addressread-writemandatoryChassis Internal Network (CIN) IPv6 address NOTE: When ipv4 is enable on one interface,this column will display all zero IPv6 address.
1.3.6.1.4.1.2.3.51.2.4.11.4NodecinStatus
1.3.6.1.4.1.2.3.51.2.4.11.4.1TablecinStatusTablenot-accessiblemandatoryTable of Chassis Internal Network (CIN) status entry information.
1.3.6.1.4.1.2.3.51.2.4.11.4.1.1RowcinStatusEntrynot-accessiblemandatoryChassis Internal Network (CIN) status table entry.
1.3.6.1.4.1.2.3.51.2.4.11.4.1.1.1ColumncinStatusIndexread-onlymandatoryThe Chassis Internal Network (CIN) status log index number. For consistent results, view as a table and not as individual entries.
1.3.6.1.4.1.2.3.51.2.4.11.4.1.1.2ColumncinStatusStringread-onlymandatoryStatus of a Chassis Internal Network (CIN) connection. For example: Index:1 VLANID:4094 IPADDR:192.168.70.100 MAC:01:0A:0B:00:01:01 Type:Learned Status:Operati…
1.3.6.1.4.1.2.3.51.2.7NoderestartReset
1.3.6.1.4.1.2.3.51.2.7.4ScalarrestartSPImmediatelyread-writemandatoryRestart the MM immediately. NOTE: Value returned for the GET command is meaningless for this MIB object.
1.3.6.1.4.1.2.3.51.2.7.5ScalarrestartStandbyMMread-writemandatoryRestarts the Standby MM from the Primary MM. NOTE: Value returned for the GET command is meaningless for this MIB object. NOTE: This mib object is only applica…
1.3.6.1.4.1.2.3.51.2.7.7ScalarswitchOverRedundantMMread-writemandatorySwitch over to the redundant Management Module. The failover will not occur if the standby or primary MM is in flashing mode. NOTE: Value returned for the GET …
1.3.6.1.4.1.2.3.51.2.7.20ScalarresetSPConfigAndRestartread-writemandatoryWill cause all the MM information to be reset to it's initial factory defaults (all previous configuration information is lost) and the MM will be re-started. …
1.3.6.1.4.1.2.3.51.2.7.21ScalarresetSPConfigAndRestartSaveLogsread-writemandatoryWill cause all the MM information to be reset to it's initial factory defaults (all previous configuration information is lost) and the MM will be re-started. …
1.3.6.1.4.1.2.3.51.2.22Nodecomponents
1.3.6.1.4.1.2.3.51.2.22.1NodeprocessorBlade
1.3.6.1.4.1.2.3.51.2.22.1.4NodebladePolicyControl
1.3.6.1.4.1.2.3.51.2.22.1.4.1TablebladePolicyControlTablenot-accessiblemandatoryTable of blade power policy control information. Contains power on/off enablement status for each blade.
1.3.6.1.4.1.2.3.51.2.22.1.4.1.1RowbladePolicyControlEntrynot-accessiblemandatoryPower policy control entry
1.3.6.1.4.1.2.3.51.2.22.1.4.1.1.1ColumnpolicyControlIndexread-onlymandatoryBlade power policy control index.
1.3.6.1.4.1.2.3.51.2.22.1.4.1.1.2ColumnpolicyControlBladeIdread-onlymandatoryThe numeric blade ID.
1.3.6.1.4.1.2.3.51.2.22.1.4.1.1.3ColumnpolicyControlBladeExistsread-onlymandatoryIndicates whether the server blade specified exists or not.
1.3.6.1.4.1.2.3.51.2.22.1.4.1.1.4ColumnpolicyControlBladePowerStateread-onlymandatoryThe power state for blade. 0 = off, 1 = on, 3 = standby, 4 = hibernate, 255 = unknown.
1.3.6.1.4.1.2.3.51.2.22.1.4.1.1.5ColumnpolicyControlBladeHealthStateread-onlymandatoryThe system health state for the blade. Unknown: Blade is in an undefined state. Good: Blade is operating normally. Warning: One or more outstanding warnings ex…
1.3.6.1.4.1.2.3.51.2.22.1.4.1.1.6ColumnpolicyControlBladeNameread-onlymandatoryThe name of the blade as a null terminated string.
1.3.6.1.4.1.2.3.51.2.22.1.4.1.1.7ColumnpolicyLocalPowerControlEnableread-writemandatoryBlade local power policy control enablement status.
1.3.6.1.4.1.2.3.51.2.22.1.4.1.1.10ColumnpolicyWakeOnLanControlEnableread-writemandatoryBlade Wake On LAN enablement status. If WOL is not supported by the blade, it displays 'notApplicable' and WOL can not be enabled or disabled.
1.3.6.1.4.1.2.3.51.2.22.1.4.2NodebladePolicy
1.3.6.1.4.1.2.3.51.2.22.1.4.2.1ScalarbladePolicyLocalPowerControlEnableread-writemandatoryBlade local power control enablement status policy.
1.3.6.1.4.1.2.3.51.2.22.1.4.2.4ScalarbladePolicyWakeOnLanControlEnableread-writemandatoryBlade Wake On LAN enablement status policy. The notApplicable(255) enumeration is not valid for SET operations. NOTE: Value returned for the GET command is mea…
1.3.6.1.4.1.2.3.51.2.22.1.5NodebladeMonitors
1.3.6.1.4.1.2.3.51.2.22.1.5.1TablebladeSystemStatusTablenot-accessiblemandatoryTable of blade status information.
1.3.6.1.4.1.2.3.51.2.22.1.5.1.1RowbladeSystemStatusEntrynot-accessiblemandatoryBlade system status entry
1.3.6.1.4.1.2.3.51.2.22.1.5.1.1.1ColumnbladeStatusIndexread-onlymandatoryBlade system status index.
1.3.6.1.4.1.2.3.51.2.22.1.5.1.1.2ColumnbladeIdread-onlymandatoryThe numeric blade ID.
1.3.6.1.4.1.2.3.51.2.22.1.5.1.1.3ColumnbladeExistsread-onlymandatoryIndicates whether the server blade specified exists or not.
1.3.6.1.4.1.2.3.51.2.22.1.5.1.1.4ColumnbladePowerStateread-onlymandatoryIndicates the power state of the blade specified.
1.3.6.1.4.1.2.3.51.2.22.1.5.1.1.5ColumnbladeHealthStateread-onlymandatoryThe system health state for the blade. Unknown: Blade is in an undefined state. Good: Blade is operating normally. Warning: One or more outstanding warnings ex…
1.3.6.1.4.1.2.3.51.2.22.1.5.1.1.6ColumnbladeNameread-onlymandatoryThe name of the blade as a null terminated string.
1.3.6.1.4.1.2.3.51.2.22.1.5.1.1.7ColumnbladeRemotePowerEnableread-onlymandatoryRemote power state for the blade.
1.3.6.1.4.1.2.3.51.2.22.1.5.1.1.10ColumnbladeConnectionTyperead-onlymandatoryConnection type of the expansion card number one.
1.3.6.1.4.1.2.3.51.2.22.1.5.1.1.13ColumnbladeRemoteWakeOnLanEnableread-onlymandatoryRemote wake on LAN state for the blade.
1.3.6.1.4.1.2.3.51.2.22.1.5.1.1.14ColumnbladeServerExpansionread-onlymandatoryThis shows whether this blade has an expansion board attached. A yes column indicates that an expansion board is installed for this blade.
1.3.6.1.4.1.2.3.51.2.22.1.5.1.1.15ColumnbladeWidthread-onlymandatoryThe width of the blade including any supplement blade attached to it
1.3.6.1.4.1.2.3.51.2.22.1.5.1.1.17ColumnbladeServerExpansion2read-onlymandatoryThis shows whether this blade has an expansion board attached. A yes column indicates that an expansion board is installed for this blade.
1.3.6.1.4.1.2.3.51.2.22.1.5.1.1.22ColumnbladeConnectionType2read-onlymandatoryConnection type of the expansion card number 2.
1.3.6.1.4.1.2.3.51.2.22.1.5.1.1.23ColumnbladeConnectionType3read-onlymandatoryConnection type of the expansion card number 3.
1.3.6.1.4.1.2.3.51.2.22.1.5.1.1.24ColumnbladeConnectionType4read-onlymandatoryConnection type of the expansion card number 4.
1.3.6.1.4.1.2.3.51.2.22.1.5.1.1.25ColumnbladeConnectionType5read-onlymandatoryConnection type of the expansion card number 5.
1.3.6.1.4.1.2.3.51.2.22.1.5.1.1.41ColumnbladeHighSpeedConnectionTyperead-onlymandatoryConnection type of the high speed expansion card number 1.
1.3.6.1.4.1.2.3.51.2.22.1.5.1.1.51ColumnbladeIOCompatibilityread-onlymandatoryI/O compatibility status for the blade. The possible values and their meanings are as follows: unknown: This indicates a communication error for the blade. ok:…
1.3.6.1.4.1.2.3.51.2.22.1.5.1.1.52ColumnbladeInventoryReadyread-onlymandatoryWhen a blade management controller or the MM is reset, the blade inventory data is refreshed in the MM database. This includes items like IBM VPD (e.g. - seria…
1.3.6.1.4.1.2.3.51.2.22.1.5.2TablebladeHealthSummaryTablenot-accessiblemandatoryTable of blade health summary information. Contains information about the overall blade health status.
1.3.6.1.4.1.2.3.51.2.22.1.5.2.1RowbladeHealthSummaryEntrynot-accessiblemandatoryBlade health summary entry
1.3.6.1.4.1.2.3.51.2.22.1.5.2.1.1ColumnbladeHealthSummaryIndexread-onlymandatoryBlade health summary index.
1.3.6.1.4.1.2.3.51.2.22.1.5.2.1.2ColumnbladeHealthSummaryBladeIdread-onlymandatoryThe numeric blade ID.
1.3.6.1.4.1.2.3.51.2.22.1.5.2.1.3ColumnbladeHealthSummarySeverityread-onlymandatorySystem health summary severity.
1.3.6.1.4.1.2.3.51.2.22.1.5.2.1.4ColumnbladeHealthSummaryDescriptionread-onlymandatorySystem health summary description.
1.3.6.1.4.1.2.3.51.2.22.1.5.2.1.5ColumnbladeHealthSummaryDateTimeread-onlymandatorySystem health summary date time.
1.3.6.1.4.1.2.3.51.2.22.1.5.2.1.6ColumnbladeHealthSummaryEventIDread-onlymandatorySystem health summary event ID.
1.3.6.1.4.1.2.3.51.2.22.1.5.3TablebladeTemperaturesTablenot-accessiblemandatoryTable of blade temperatures information.
1.3.6.1.4.1.2.3.51.2.22.1.5.3.1RowbladeTemperaturesEntrynot-accessiblemandatoryBlade temperatures table entry
1.3.6.1.4.1.2.3.51.2.22.1.5.3.1.1ColumntemperatureIndexread-onlymandatoryBlade temperatures table index.
1.3.6.1.4.1.2.3.51.2.22.1.5.3.1.2ColumntemperatureBladeIdread-onlymandatoryThe numeric blade ID.
1.3.6.1.4.1.2.3.51.2.22.1.5.3.1.3ColumntemperatureBladeExistsread-onlymandatoryIndicates whether the server blade specified exists or not.
1.3.6.1.4.1.2.3.51.2.22.1.5.3.1.4ColumntemperatureBladePowerStateread-onlymandatoryIndicates the power state of the blade specified.
1.3.6.1.4.1.2.3.51.2.22.1.5.3.1.5ColumntemperatureBladeNameread-onlymandatoryThe name of the blade as a null terminated string.
1.3.6.1.4.1.2.3.51.2.22.1.5.3.1.6ColumntemperatureCPU1read-onlymandatoryThe blade CPU temperature in degrees centigrade(C). An octet string expressed as 'sddd.dd Centigrade' where: s is the sign ('-' for negative or blank space for…
1.3.6.1.4.1.2.3.51.2.22.1.5.3.1.7ColumntemperatureCPU2read-onlymandatoryThe blade CPU temperature in degrees centigrade(C). An octet string expressed as 'sddd.dd Centigrade' where: s is the sign ('-' for negative or blank space for…
1.3.6.1.4.1.2.3.51.2.22.1.5.3.1.8ColumntemperatureCPU3read-onlymandatoryThe blade CPU temperature in degrees centigrade(C). An octet string expressed as 'sddd.dd Centigrade' where: s is the sign ('-' for negative or blank space for…
1.3.6.1.4.1.2.3.51.2.22.1.5.3.1.9ColumntemperatureCPU4read-onlymandatoryThe blade CPU temperature in degrees centigrade(C). An octet string expressed as 'sddd.dd Centigrade' where: s is the sign ('-' for negative or blank space for…
1.3.6.1.4.1.2.3.51.2.22.1.5.3.1.10ColumntemperatureDASD1read-onlymandatoryThe blade DASD temperature in degrees centigrade(C). An octet string expressed as 'sddd.dd Centigrade' where: s is the sign ('-' for negative or blank space fo…
1.3.6.1.4.1.2.3.51.2.22.1.5.3.1.11ColumnbladeSensorTempCapabilityread-onlymandatoryIndicates whether the server blade is IPMI capable or not.
1.3.6.1.4.1.2.3.51.2.22.1.5.3.1.12ColumnbladeSensor1Tempread-onlymandatoryTemperature reading for an IPMI blade expressed in degrees centigrade(C). An octet string expressed as 'sddd.dd Centigrade' where: s is the sign ('-' for negat…
1.3.6.1.4.1.2.3.51.2.22.1.5.3.1.13ColumnbladeSensor2Tempread-onlymandatoryTemperature reading for an IPMI blade expressed in degrees centigrade(C). An octet string expressed as 'sddd.dd Centigrade' where: s is the sign ('-' for negat…
1.3.6.1.4.1.2.3.51.2.22.1.5.3.1.14ColumnbladeSensor3Tempread-onlymandatoryTemperature reading for an IPMI blade expressed in degrees centigrade(C). An octet string expressed as 'sddd.dd Centigrade' where: s is the sign ('-' for negat…
1.3.6.1.4.1.2.3.51.2.22.1.5.3.1.15ColumnbladeSensor4Tempread-onlymandatoryTemperature reading for an IPMI blade expressed in degrees centigrade(C). An octet string expressed as 'sddd.dd Centigrade' where: s is the sign ('-' for negat…
1.3.6.1.4.1.2.3.51.2.22.1.5.3.1.16ColumnbladeSensor5Tempread-onlymandatoryTemperature reading for an IPMI blade expressed in degrees centigrade(C). An octet string expressed as 'sddd.dd Centigrade' where: s is the sign ('-' for negat…
1.3.6.1.4.1.2.3.51.2.22.1.5.3.1.17ColumnbladeSensor6Tempread-onlymandatoryTemperature reading for an IPMI blade expressed in degrees centigrade(C). An octet string expressed as 'sddd.dd Centigrade' where: s is the sign ('-' for negat…
1.3.6.1.4.1.2.3.51.2.22.1.5.3.1.18ColumnbladeSensor7Tempread-onlymandatoryTemperature reading for an IPMI blade expressed in degrees centigrade(C). An octet string expressed as 'sddd.dd Centigrade' where: s is the sign ('-' for negat…
1.3.6.1.4.1.2.3.51.2.22.1.5.3.1.19ColumnbladeSensor8Tempread-onlymandatoryTemperature reading for an IPMI blade expressed in degrees centigrade(C). An octet string expressed as 'sddd.dd Centigrade' where: s is the sign ('-' for negat…
1.3.6.1.4.1.2.3.51.2.22.1.5.3.1.20ColumnbladeSensor9Tempread-onlymandatoryTemperature reading for an IPMI blade expressed in degrees centigrade(C). An octet string expressed as 'sddd.dd Centigrade' where: s is the sign ('-' for negat…
1.3.6.1.4.1.2.3.51.2.22.1.5.4TablebladeTemperatureThresholdsTablenot-accessiblemandatoryTable of blade temperature thresholds information.
1.3.6.1.4.1.2.3.51.2.22.1.5.4.1RowbladeTemperatureThresholdsEntrynot-accessiblemandatoryBlade temperature thresholds table entry
1.3.6.1.4.1.2.3.51.2.22.1.5.4.1.1ColumntemperatureThresholdIndexread-onlymandatoryBlade temperature threshold table index.
1.3.6.1.4.1.2.3.51.2.22.1.5.4.1.2ColumntemperatureThresholdBladeIdread-onlymandatoryThe numeric blade ID.
1.3.6.1.4.1.2.3.51.2.22.1.5.4.1.3ColumntemperatureThresholdBladeExistsread-onlymandatoryIndicates whether the server blade specified exists or not.
1.3.6.1.4.1.2.3.51.2.22.1.5.4.1.4ColumntemperatureThresholdBladePowerStateread-onlymandatoryIndicates the power state of the blade specified.
1.3.6.1.4.1.2.3.51.2.22.1.5.4.1.5ColumntemperatureThresholdBladeNameread-onlymandatoryThe name of the blade as a null terminated string.
1.3.6.1.4.1.2.3.51.2.22.1.5.4.1.6ColumntemperatureCPU1HardShutdownread-onlymandatoryThe blade CPU hard shutdown temperature in degrees centigrade(C). If the component's temperature rises above this value the system will be powered off immediat…
1.3.6.1.4.1.2.3.51.2.22.1.5.4.1.7ColumntemperatureCPU1Warningread-onlymandatoryThe blade CPU warning temperature in degrees centigrade(C). If the temperature rises above this value a warning alert/event if enabled will be generated. An oc…
1.3.6.1.4.1.2.3.51.2.22.1.5.4.1.8ColumntemperatureCPU1WarningResetread-onlymandatoryThe blade CPU warning reset temperature in degrees centigrade(C). If the temperature rises above this value and if a warning alert/event had previously been cr…
1.3.6.1.4.1.2.3.51.2.22.1.5.4.1.9ColumntemperatureCPU2HardShutdownread-onlymandatoryThe blade CPU hard shutdown temperature in degrees centigrade(C). If the component's temperature rises above this value the system will be powered off immediat…
1.3.6.1.4.1.2.3.51.2.22.1.5.4.1.10ColumntemperatureCPU2Warningread-onlymandatoryThe blade CPU warning temperature in degrees centigrade(C). If the temperature rises above this value a warning alert/event if enabled will be generated. An oc…
1.3.6.1.4.1.2.3.51.2.22.1.5.4.1.11ColumntemperatureCPU2WarningResetread-onlymandatoryThe blade CPU warning reset temperature in degrees centigrade(C). If the temperature rises above this value and if a warning alert/event had previously been cr…
1.3.6.1.4.1.2.3.51.2.22.1.5.4.1.12ColumntemperatureCPU3HardShutdownread-onlymandatoryThe blade CPU hard shutdown temperature in degrees centigrade(C). If the component's temperature rises above this value the system will be powered off immediat…
1.3.6.1.4.1.2.3.51.2.22.1.5.4.1.13ColumntemperatureCPU3Warningread-onlymandatoryThe blade CPU warning temperature in degrees centigrade(C). If the temperature rises above this value a warning alert/event if enabled will be generated. An oc…
1.3.6.1.4.1.2.3.51.2.22.1.5.4.1.14ColumntemperatureCPU3WarningResetread-onlymandatoryThe blade CPU warning reset temperature in degrees centigrade(C). If the temperature rises above this value and if a warning alert/event had previously been cr…
1.3.6.1.4.1.2.3.51.2.22.1.5.4.1.15ColumntemperatureCPU4HardShutdownread-onlymandatoryThe blade CPU hard shutdown temperature in degrees centigrade(C). If the component's temperature rises above this value the system will be powered off immediat…
1.3.6.1.4.1.2.3.51.2.22.1.5.4.1.16ColumntemperatureCPU4Warningread-onlymandatoryThe blade CPU warning temperature in degrees centigrade(C). If the temperature rises above this value a warning alert/event if enabled will be generated. An oc…
1.3.6.1.4.1.2.3.51.2.22.1.5.4.1.17ColumntemperatureCPU4WarningResetread-onlymandatoryThe blade CPU warning reset temperature in degrees centigrade(C). If the temperature rises above this value and if a warning alert/event had previously been cr…
1.3.6.1.4.1.2.3.51.2.22.1.5.4.1.18ColumntemperatureDASD1HardShutdownread-onlymandatoryThe blade DASD hard shutdown temperature in degrees centigrade(C). An octet string expressed as 'sddd.dd Centigrade' where: s is the sign ('-' for negative or …
1.3.6.1.4.1.2.3.51.2.22.1.5.4.1.19ColumntemperatureDASD1Warningread-onlymandatoryThe blade DASD warning temperature in degrees centigrade(C). An octet string expressed as 'sddd.dd Centigrade' where: s is the sign ('-' for negative or blank …
1.3.6.1.4.1.2.3.51.2.22.1.5.4.1.20ColumntemperatureDASD1WarningResetread-onlymandatoryThe blade DASD warning reset temperature in degrees centigrade(C). An octet string expressed as 'sddd.dd Centigrade' where: s is the sign ('-' for negative or …
1.3.6.1.4.1.2.3.51.2.22.1.5.4.1.21ColumnbladeTempThresholdSensorCapabilityread-onlymandatoryIndicates whether the server blade is IPMI capable or not.
1.3.6.1.4.1.2.3.51.2.22.1.5.4.1.22ColumntemperatureSensor1HardShutdownread-onlymandatoryThe blade hard shutdown temperature for IPMI blades in degrees centigrade(C). An octet string expressed as 'sddd.dd Centigrade' where: s is the sign ('-' for n…
1.3.6.1.4.1.2.3.51.2.22.1.5.4.1.23ColumntemperatureSensor1Warningread-onlymandatoryThe blade hard shutdown temperature for IPMI blades in degrees centigrade(C). An octet string expressed as 'sddd.dd Centigrade' where: s is the sign ('-' for n…
1.3.6.1.4.1.2.3.51.2.22.1.5.4.1.24ColumntemperatureSensor1WarningResetread-onlymandatoryThe blade hard shutdown temperature for IPMI blades in degrees centigrade(C). An octet string expressed as 'sddd.dd Centigrade' where: s is the sign ('-' for n…
1.3.6.1.4.1.2.3.51.2.22.1.5.4.1.25ColumntemperatureSensor2HardShutdownread-onlymandatoryThe blade hard shutdown temperature for IPMI blades in degrees centigrade(C). An octet string expressed as 'sddd.dd Centigrade' where: s is the sign ('-' for n…
1.3.6.1.4.1.2.3.51.2.22.1.5.4.1.26ColumntemperatureSensor2Warningread-onlymandatoryThe blade hard shutdown temperature for IPMI blades in degrees centigrade(C). An octet string expressed as 'sddd.dd Centigrade' where: s is the sign ('-' for n…
1.3.6.1.4.1.2.3.51.2.22.1.5.4.1.27ColumntemperatureSensor2WarningResetread-onlymandatoryThe blade hard shutdown temperature for IPMI blades in degrees centigrade(C). An octet string expressed as 'sddd.dd Centigrade' where: s is the sign ('-' for n…
1.3.6.1.4.1.2.3.51.2.22.1.5.4.1.28ColumntemperatureSensor3HardShutdownread-onlymandatoryThe blade hard shutdown temperature for IPMI blades in degrees centigrade(C). An octet string expressed as 'sddd.dd Centigrade' where: s is the sign ('-' for n…
1.3.6.1.4.1.2.3.51.2.22.1.5.4.1.29ColumntemperatureSensor3Warningread-onlymandatoryThe blade hard shutdown temperature for IPMI blades in degrees centigrade(C). An octet string expressed as 'sddd.dd Centigrade' where: s is the sign ('-' for n…
1.3.6.1.4.1.2.3.51.2.22.1.5.4.1.30ColumntemperatureSensor3WarningResetread-onlymandatoryThe blade hard shutdown temperature for IPMI blades in degrees centigrade(C). An octet string expressed as 'sddd.dd Centigrade' where: s is the sign ('-' for n…
1.3.6.1.4.1.2.3.51.2.22.1.5.4.1.31ColumntemperatureSensor4HardShutdownread-onlymandatoryThe blade hard shutdown temperature for IPMI blades in degrees centigrade(C). An octet string expressed as 'sddd.dd Centigrade' where: s is the sign ('-' for n…
1.3.6.1.4.1.2.3.51.2.22.1.5.4.1.32ColumntemperatureSensor4Warningread-onlymandatoryThe blade hard shutdown temperature for IPMI blades in degrees centigrade(C). An octet string expressed as 'sddd.dd Centigrade' where: s is the sign ('-' for n…
1.3.6.1.4.1.2.3.51.2.22.1.5.4.1.33ColumntemperatureSensor4WarningResetread-onlymandatoryThe blade hard shutdown temperature for IPMI blades in degrees centigrade(C). An octet string expressed as 'sddd.dd Centigrade' where: s is the sign ('-' for n…
1.3.6.1.4.1.2.3.51.2.22.1.5.4.1.34ColumntemperatureSensor5HardShutdownread-onlymandatoryThe blade hard shutdown temperature for IPMI blades in degrees centigrade(C). An octet string expressed as 'sddd.dd Centigrade' where: s is the sign ('-' for n…
1.3.6.1.4.1.2.3.51.2.22.1.5.4.1.35ColumntemperatureSensor5Warningread-onlymandatoryThe blade hard shutdown temperature for IPMI blades in degrees centigrade(C). An octet string expressed as 'sddd.dd Centigrade' where: s is the sign ('-' for n…
1.3.6.1.4.1.2.3.51.2.22.1.5.4.1.36ColumntemperatureSensor5WarningResetread-onlymandatoryThe blade hard shutdown temperature for IPMI blades in degrees centigrade(C). An octet string expressed as 'sddd.dd Centigrade' where: s is the sign ('-' for n…
1.3.6.1.4.1.2.3.51.2.22.1.5.4.1.37ColumntemperatureSensor6HardShutdownread-onlymandatoryThe blade hard shutdown temperature for IPMI blades in degrees centigrade(C). An octet string expressed as 'sddd.dd Centigrade' where: s is the sign ('-' for n…
1.3.6.1.4.1.2.3.51.2.22.1.5.4.1.38ColumntemperatureSensor6Warningread-onlymandatoryThe blade hard shutdown temperature for IPMI blades in degrees centigrade(C). An octet string expressed as 'sddd.dd Centigrade' where: s is the sign ('-' for n…
1.3.6.1.4.1.2.3.51.2.22.1.5.4.1.39ColumntemperatureSensor6WarningResetread-onlymandatoryThe blade hard shutdown temperature for IPMI blades in degrees centigrade(C). An octet string expressed as 'sddd.dd Centigrade' where: s is the sign ('-' for n…
1.3.6.1.4.1.2.3.51.2.22.1.5.4.1.40ColumntemperatureSensor7HardShutdownread-onlymandatoryThe blade hard shutdown temperature for IPMI blades in degrees centigrade(C). An octet string expressed as 'sddd.dd Centigrade' where: s is the sign ('-' for n…
1.3.6.1.4.1.2.3.51.2.22.1.5.4.1.41ColumntemperatureSensor7Warningread-onlymandatoryThe blade hard shutdown temperature for IPMI blades in degrees centigrade(C). An octet string expressed as 'sddd.dd Centigrade' where: s is the sign ('-' for n…
1.3.6.1.4.1.2.3.51.2.22.1.5.4.1.42ColumntemperatureSensor7WarningResetread-onlymandatoryThe blade hard shutdown temperature for IPMI blades in degrees centigrade(C). An octet string expressed as 'sddd.dd Centigrade' where: s is the sign ('-' for n…
1.3.6.1.4.1.2.3.51.2.22.1.5.4.1.43ColumntemperatureSensor8HardShutdownread-onlymandatoryThe blade hard shutdown temperature for IPMI blades in degrees centigrade(C). An octet string expressed as 'sddd.dd Centigrade' where: s is the sign ('-' for n…
1.3.6.1.4.1.2.3.51.2.22.1.5.4.1.44ColumntemperatureSensor8Warningread-onlymandatoryThe blade hard shutdown temperature for IPMI blades in degrees centigrade(C). An octet string expressed as 'sddd.dd Centigrade' where: s is the sign ('-' for n…
1.3.6.1.4.1.2.3.51.2.22.1.5.4.1.45ColumntemperatureSensor8WarningResetread-onlymandatoryThe blade hard shutdown temperature for IPMI blades in degrees centigrade(C). An octet string expressed as 'sddd.dd Centigrade' where: s is the sign ('-' for n…
1.3.6.1.4.1.2.3.51.2.22.1.5.4.1.46ColumntemperatureSensor9HardShutdownread-onlymandatoryThe blade hard shutdown temperature for IPMI blades in degrees centigrade(C). An octet string expressed as 'sddd.dd Centigrade' where: s is the sign ('-' for n…
1.3.6.1.4.1.2.3.51.2.22.1.5.4.1.47ColumntemperatureSensor9Warningread-onlymandatoryThe blade hard shutdown temperature for IPMI blades in degrees centigrade(C). An octet string expressed as 'sddd.dd Centigrade' where: s is the sign ('-' for n…
1.3.6.1.4.1.2.3.51.2.22.1.5.4.1.48ColumntemperatureSensor9WarningResetread-onlymandatoryThe blade hard shutdown temperature for IPMI blades in degrees centigrade(C). An octet string expressed as 'sddd.dd Centigrade' where: s is the sign ('-' for n…
1.3.6.1.4.1.2.3.51.2.22.1.5.5TablebladeVoltagesTablenot-accessiblemandatoryTable of blade voltages information.
1.3.6.1.4.1.2.3.51.2.22.1.5.5.1RowbladeVoltagesEntrynot-accessiblemandatoryBlade voltages table entry
1.3.6.1.4.1.2.3.51.2.22.1.5.5.1.1ColumnvoltageIndexread-onlymandatoryBlade voltages table index.
1.3.6.1.4.1.2.3.51.2.22.1.5.5.1.2ColumnvoltageBladeIdread-onlymandatoryThe numeric blade ID.
1.3.6.1.4.1.2.3.51.2.22.1.5.5.1.3ColumnvoltageBladeExistsread-onlymandatoryIndicates whether the server blade specified exists or not.
1.3.6.1.4.1.2.3.51.2.22.1.5.5.1.4ColumnvoltageBladePowerStateread-onlymandatoryIndicates the power state of the blade specified.
1.3.6.1.4.1.2.3.51.2.22.1.5.5.1.5ColumnvoltageBladeNameread-onlymandatoryThe name of the blade as a null terminated string.
1.3.6.1.4.1.2.3.51.2.22.1.5.5.1.6ColumnbladePlus5Voltread-onlymandatory+5 Volt power supply voltage reading for the blade expressed in Volts(V). An octet string expressed as 'sdd.dd Volts' where: s is the sign ('-' for negative or…
1.3.6.1.4.1.2.3.51.2.22.1.5.5.1.7ColumnbladePlus3pt3Voltread-onlymandatory+3.3 Volt power supply voltage reading for the blade expressed in Volts(V). An octet string expressed as 'sdd.dd Volts' where: s is the sign ('-' for negative …
1.3.6.1.4.1.2.3.51.2.22.1.5.5.1.8ColumnbladePlus12Voltread-onlymandatory+12 Volt power supply voltage reading for the blade expressed in Volts(V). An octet string expressed as 'sdd.dd Volts' where: s is the sign ('-' for negative o…
1.3.6.1.4.1.2.3.51.2.22.1.5.5.1.10ColumnbladePlus2pt5Voltread-onlymandatory+2.5 Volt power supply voltage reading for the blade expressed in Volts(V). An octet string expressed as 'sdd.dd Volts' where: s is the sign ('-' for negative …
1.3.6.1.4.1.2.3.51.2.22.1.5.5.1.11ColumnbladePlus1pt5Voltread-onlymandatory+1.5 Volt power supply voltage reading for the blade expressed in Volts(V). An octet string expressed as 'sdd.dd Volts' where: s is the sign ('-' for negative …
1.3.6.1.4.1.2.3.51.2.22.1.5.5.1.12ColumnbladePlus1pt25Voltread-onlymandatory+1.25 Volt power supply voltage reading for the blade expressed in Volts(V). An octet string expressed as 'sdd.dd Volts' where: s is the sign ('-' for negative…
1.3.6.1.4.1.2.3.51.2.22.1.5.5.1.13ColumnbladeVRM1Voltread-onlymandatoryVRM 1 voltage reading for the blade expressed in Volts(V). An octet string expressed as 'sdd.dd Volts' where: s is the sign ('-' for negative or '+' for positi…
1.3.6.1.4.1.2.3.51.2.22.1.5.5.1.14ColumnbladeSensorVoltCapabilityread-onlymandatoryIndicates whether the server blade is IPMI capable or not.
1.3.6.1.4.1.2.3.51.2.22.1.5.5.1.15ColumnbladeSensor1Voltread-onlymandatoryVoltage reading for an IPMI blade expressed in Volts(V). An octet string expressed as 'sdd.dd Volts' where: s is the sign ('-' for negative or '+' for positive…
1.3.6.1.4.1.2.3.51.2.22.1.5.5.1.16ColumnbladeSensor2Voltread-onlymandatoryVoltage reading for an IPMI blade expressed in Volts(V). An octet string expressed as 'sdd.dd Volts' where: s is the sign ('-' for negative or '+' for positive…
1.3.6.1.4.1.2.3.51.2.22.1.5.5.1.17ColumnbladeSensor3Voltread-onlymandatoryVoltage reading for an IPMI blade expressed in Volts(V). An octet string expressed as 'sdd.dd Volts' where: s is the sign ('-' for negative or '+' for positive…
1.3.6.1.4.1.2.3.51.2.22.1.5.5.1.18ColumnbladeSensor4Voltread-onlymandatoryVoltage reading for an IPMI blade expressed in Volts(V). An octet string expressed as 'sdd.dd Volts' where: s is the sign ('-' for negative or '+' for positive…
1.3.6.1.4.1.2.3.51.2.22.1.5.5.1.19ColumnbladeSensor5Voltread-onlymandatoryVoltage reading for an IPMI blade expressed in Volts(V). An octet string expressed as 'sdd.dd Volts' where: s is the sign ('-' for negative or '+' for positive…
1.3.6.1.4.1.2.3.51.2.22.1.5.5.1.20ColumnbladeSensor6Voltread-onlymandatoryVoltage reading for an IPMI blade expressed in Volts(V). An octet string expressed as 'sdd.dd Volts' where: s is the sign ('-' for negative or '+' for positive…
1.3.6.1.4.1.2.3.51.2.22.1.5.5.1.21ColumnbladeSensor7Voltread-onlymandatoryVoltage reading for an IPMI blade expressed in Volts(V). An octet string expressed as 'sdd.dd Volts' where: s is the sign ('-' for negative or '+' for positive…
1.3.6.1.4.1.2.3.51.2.22.1.5.5.1.22ColumnbladeSensor8Voltread-onlymandatoryVoltage reading for an IPMI blade expressed in Volts(V). An octet string expressed as 'sdd.dd Volts' where: s is the sign ('-' for negative or '+' for positive…
1.3.6.1.4.1.2.3.51.2.22.1.5.5.1.23ColumnbladeSensor9Voltread-onlymandatoryVoltage reading for an IPMI blade expressed in Volts(V). An octet string expressed as 'sdd.dd Volts' where: s is the sign ('-' for negative or '+' for positive…
1.3.6.1.4.1.2.3.51.2.22.1.5.5.1.24ColumnbladeSensor10Voltread-onlymandatoryVoltage reading for an IPMI blade expressed in Volts(V). An octet string expressed as 'sdd.dd Volts' where: s is the sign ('-' for negative or '+' for positive…
1.3.6.1.4.1.2.3.51.2.22.1.5.5.1.25ColumnbladeSensor11Voltread-onlymandatoryVoltage reading for an IPMI blade expressed in Volts(V). An octet string expressed as 'sdd.dd Volts' where: s is the sign ('-' for negative or '+' for positive…
1.3.6.1.4.1.2.3.51.2.22.1.5.5.1.26ColumnbladeSensor12Voltread-onlymandatoryVoltage reading for an IPMI blade expressed in Volts(V). An octet string expressed as 'sdd.dd Volts' where: s is the sign ('-' for negative or '+' for positive…
1.3.6.1.4.1.2.3.51.2.22.1.5.5.1.27ColumnbladeSensor13Voltread-onlymandatoryVoltage reading for an IPMI blade expressed in Volts(V). An octet string expressed as 'sdd.dd Volts' where: s is the sign ('-' for negative or '+' for positive…
1.3.6.1.4.1.2.3.51.2.22.1.5.5.1.28ColumnbladeSensor14Voltread-onlymandatoryVoltage reading for an IPMI blade expressed in Volts(V). An octet string expressed as 'sdd.dd Volts' where: s is the sign ('-' for negative or '+' for positive…
1.3.6.1.4.1.2.3.51.2.22.1.5.5.1.29ColumnbladeSensor15Voltread-onlymandatoryVoltage reading for an IPMI blade expressed in Volts(V). An octet string expressed as 'sdd.dd Volts' where: s is the sign ('-' for negative or '+' for positive…
1.3.6.1.4.1.2.3.51.2.22.1.5.5.1.30ColumnbladeSensor16Voltread-onlymandatoryVoltage reading for an IPMI blade expressed in Volts(V). An octet string expressed as 'sdd.dd Volts' where: s is the sign ('-' for negative or '+' for positive…
1.3.6.1.4.1.2.3.51.2.22.1.5.5.1.31ColumnbladeSensor17Voltread-onlymandatoryVoltage reading for an IPMI blade expressed in Volts(V). An octet string expressed as 'sdd.dd Volts' where: s is the sign ('-' for negative or '+' for positive…
1.3.6.1.4.1.2.3.51.2.22.1.5.5.1.32ColumnbladeSensor18Voltread-onlymandatoryVoltage reading for an IPMI blade expressed in Volts(V). An octet string expressed as 'sdd.dd Volts' where: s is the sign ('-' for negative or '+' for positive…
1.3.6.1.4.1.2.3.51.2.22.1.5.5.1.33ColumnbladeSensor19Voltread-onlymandatoryVoltage reading for an IPMI blade expressed in Volts(V). An octet string expressed as 'sdd.dd Volts' where: s is the sign ('-' for negative or '+' for positive…
1.3.6.1.4.1.2.3.51.2.22.1.5.5.1.34ColumnbladeSensor20Voltread-onlymandatoryVoltage reading for an IPMI blade expressed in Volts(V). An octet string expressed as 'sdd.dd Volts' where: s is the sign ('-' for negative or '+' for positive…
1.3.6.1.4.1.2.3.51.2.22.1.5.5.1.35ColumnbladeSensor21Voltread-onlymandatoryVoltage reading for an IPMI blade expressed in Volts(V). An octet string expressed as 'sdd.dd Volts' where: s is the sign ('-' for negative or '+' for positive…
1.3.6.1.4.1.2.3.51.2.22.1.5.5.1.36ColumnbladeSensor22Voltread-onlymandatoryVoltage reading for an IPMI blade expressed in Volts(V). An octet string expressed as 'sdd.dd Volts' where: s is the sign ('-' for negative or '+' for positive…
1.3.6.1.4.1.2.3.51.2.22.1.5.5.1.37ColumnbladeSensor23Voltread-onlymandatoryVoltage reading for an IPMI blade expressed in Volts(V). An octet string expressed as 'sdd.dd Volts' where: s is the sign ('-' for negative or '+' for positive…
1.3.6.1.4.1.2.3.51.2.22.1.5.5.1.38ColumnbladeSensor24Voltread-onlymandatoryVoltage reading for an IPMI blade expressed in Volts(V). An octet string expressed as 'sdd.dd Volts' where: s is the sign ('-' for negative or '+' for positive…
1.3.6.1.4.1.2.3.51.2.22.1.5.5.1.39ColumnbladeSensor25Voltread-onlymandatoryVoltage reading for an IPMI blade expressed in Volts(V). An octet string expressed as 'sdd.dd Volts' where: s is the sign ('-' for negative or '+' for positive…
1.3.6.1.4.1.2.3.51.2.22.1.5.5.1.40ColumnbladeSensor26Voltread-onlymandatoryVoltage reading for an IPMI blade expressed in Volts(V). An octet string expressed as 'sdd.dd Volts' where: s is the sign ('-' for negative or '+' for positive…
1.3.6.1.4.1.2.3.51.2.22.1.5.5.1.41ColumnbladeSensor27Voltread-onlymandatoryVoltage reading for an IPMI blade expressed in Volts(V). An octet string expressed as 'sdd.dd Volts' where: s is the sign ('-' for negative or '+' for positive…
1.3.6.1.4.1.2.3.51.2.22.1.5.5.1.42ColumnbladeSensor28Voltread-onlymandatoryVoltage reading for an IPMI blade expressed in Volts(V). An octet string expressed as 'sdd.dd Volts' where: s is the sign ('-' for negative or '+' for positive…
1.3.6.1.4.1.2.3.51.2.22.1.5.5.1.43ColumnbladeSensor29Voltread-onlymandatoryVoltage reading for an IPMI blade expressed in Volts(V). An octet string expressed as 'sdd.dd Volts' where: s is the sign ('-' for negative or '+' for positive…
1.3.6.1.4.1.2.3.51.2.22.1.5.5.1.44ColumnbladeSensor30Voltread-onlymandatoryVoltage reading for an IPMI blade expressed in Volts(V). An octet string expressed as 'sdd.dd Volts' where: s is the sign ('-' for negative or '+' for positive…
1.3.6.1.4.1.2.3.51.2.22.1.5.6TablebladeVoltageThresholdsTablenot-accessiblemandatoryTable of blade VoltageThresholds information.
1.3.6.1.4.1.2.3.51.2.22.1.5.6.1RowbladeVoltageThresholdsEntrynot-accessiblemandatoryBlade voltage thresholds table entry
1.3.6.1.4.1.2.3.51.2.22.1.5.6.1.1ColumnvoltageThresholdIndexread-onlymandatoryBlade voltage thresholds table index.
1.3.6.1.4.1.2.3.51.2.22.1.5.6.1.2ColumnvoltageThresholdBladeIdread-onlymandatoryThe numeric blade ID.
1.3.6.1.4.1.2.3.51.2.22.1.5.6.1.3ColumnvoltageThresholdBladeExistsread-onlymandatoryIndicates whether the server blade specified exists or not.
1.3.6.1.4.1.2.3.51.2.22.1.5.6.1.4ColumnvoltageThresholdBladePowerStateread-onlymandatoryIndicates the power state of the blade specified.
1.3.6.1.4.1.2.3.51.2.22.1.5.6.1.5ColumnvoltageThresholdBladeNameread-writemandatoryThe name of the blade as a null terminated string.
1.3.6.1.4.1.2.3.51.2.22.1.5.6.1.6ColumnbladePlus5VoltHighWarningread-onlymandatoryVoltage warning threshold reading expressed in Volts(V). If the voltage rises above this value a warning alert/event if enabled will be generated. An octet str…
1.3.6.1.4.1.2.3.51.2.22.1.5.6.1.7ColumnbladePlus5VoltLowWarningread-onlymandatoryVoltage warning threshold reading expressed in Volts(V). If the voltage drops below this value a warning alert/event if enabled will be generated. An octet str…
1.3.6.1.4.1.2.3.51.2.22.1.5.6.1.8ColumnbladePlus3pt3VoltHighWarningread-onlymandatoryVoltage warning threshold reading expressed in Volts(V). If the voltage rises above this value a warning alert/event if enabled will be generated. An octet str…
1.3.6.1.4.1.2.3.51.2.22.1.5.6.1.9ColumnbladePlus3pt3VoltLowWarningread-onlymandatoryVoltage warning threshold reading expressed in Volts(V). If the voltage drops below this value a warning alert/event if enabled will be generated. An octet str…
1.3.6.1.4.1.2.3.51.2.22.1.5.6.1.10ColumnbladePlus12VoltHighWarningread-onlymandatoryVoltage warning threshold reading expressed in Volts(V). If the voltage rises above this value a warning alert/event if enabled will be generated. An octet str…
1.3.6.1.4.1.2.3.51.2.22.1.5.6.1.11ColumnbladePlus12VoltLowWarningread-onlymandatoryVoltage warning threshold reading expressed in Volts(V). If the voltage drops below this value a warning alert/event if enabled will be generated. An octet str…
1.3.6.1.4.1.2.3.51.2.22.1.5.6.1.14ColumnbladePlus2pt5VoltHighWarningread-onlymandatoryVoltage warning threshold reading expressed in Volts(V). If the voltage rises above this value a warning alert/event if enabled will be generated. An octet str…
1.3.6.1.4.1.2.3.51.2.22.1.5.6.1.15ColumnbladePlus2pt5VoltLowWarningread-onlymandatoryVoltage warning threshold reading expressed in Volts(V). If the voltage drops below this value a warning alert/event if enabled will be generated. An octet str…
1.3.6.1.4.1.2.3.51.2.22.1.5.6.1.16ColumnbladePlus1pt5VoltHighWarningread-onlymandatoryVoltage warning threshold reading expressed in Volts(V). If the voltage rises above this value a warning alert/event if enabled will be generated. An octet str…
1.3.6.1.4.1.2.3.51.2.22.1.5.6.1.17ColumnbladePlus1pt5VoltLowWarningread-onlymandatoryVoltage warning threshold reading expressed in Volts(V). If the voltage drops below this value a warning alert/event if enabled will be generated. An octet str…
1.3.6.1.4.1.2.3.51.2.22.1.5.6.1.18ColumnbladePlus1pt25VoltHighWarningread-onlymandatoryVoltage warning threshold reading expressed in Volts(V). If the voltage rises above this value a warning alert/event if enabled will be generated. An octet str…
1.3.6.1.4.1.2.3.51.2.22.1.5.6.1.19ColumnbladePlus1pt25VoltLowWarningread-onlymandatoryVoltage warning threshold reading expressed in Volts(V). If the voltage drops below this value a warning alert/event if enabled will be generated. An octet str…
1.3.6.1.4.1.2.3.51.2.22.1.5.6.1.22ColumnbladeVoltThresholdSensorCapabilityread-onlymandatoryIndicates whether the server blade is IPMI capable or not.
1.3.6.1.4.1.2.3.51.2.22.1.5.6.1.23ColumnbladeSensor1VoltHighWarningread-onlymandatoryVoltage warning threshold reading for IPMI blades expressed in Volts(V). If the voltage rises above this value, a critical alert/event if enabled will be gener…
1.3.6.1.4.1.2.3.51.2.22.1.5.6.1.24ColumnbladeSensor1VoltLowWarningread-onlymandatoryVoltage warning threshold reading for IPMI blades expressed in Volts(V). If the voltage drops below this value, a critical alert/event if enabled will be gener…
1.3.6.1.4.1.2.3.51.2.22.1.5.6.1.25ColumnbladeSensor2VoltHighWarningread-onlymandatoryVoltage warning threshold reading for IPMI blades expressed in Volts(V). If the voltage rises above this value, a critical alert/event if enabled will be gener…
1.3.6.1.4.1.2.3.51.2.22.1.5.6.1.26ColumnbladeSensor2VoltLowWarningread-onlymandatoryVoltage warning threshold reading for IPMI blades expressed in Volts(V). If the voltage drops below this value, a critical alert/event if enabled will be gener…
1.3.6.1.4.1.2.3.51.2.22.1.5.6.1.27ColumnbladeSensor3VoltHighWarningread-onlymandatoryVoltage warning threshold reading for IPMI blades expressed in Volts(V). If the voltage rises above this value, a critical alert/event if enabled will be gener…
1.3.6.1.4.1.2.3.51.2.22.1.5.6.1.28ColumnbladeSensor3VoltLowWarningread-onlymandatoryVoltage warning threshold reading for IPMI blades expressed in Volts(V). If the voltage drops below this value, a critical alert/event if enabled will be gener…
1.3.6.1.4.1.2.3.51.2.22.1.5.6.1.29ColumnbladeSensor4VoltHighWarningread-onlymandatoryVoltage warning threshold reading for IPMI blades expressed in Volts(V). If the voltage rises above this value, a critical alert/event if enabled will be gener…
1.3.6.1.4.1.2.3.51.2.22.1.5.6.1.30ColumnbladeSensor4VoltLowWarningread-onlymandatoryVoltage warning threshold reading for IPMI blades expressed in Volts(V). If the voltage drops below this value, a critical alert/event if enabled will be gener…
1.3.6.1.4.1.2.3.51.2.22.1.5.6.1.31ColumnbladeSensor5VoltHighWarningread-onlymandatoryVoltage warning threshold reading for IPMI blades expressed in Volts(V). If the voltage rises above this value, a critical alert/event if enabled will be gener…
1.3.6.1.4.1.2.3.51.2.22.1.5.6.1.32ColumnbladeSensor5VoltLowWarningread-onlymandatoryVoltage warning threshold reading for IPMI blades expressed in Volts(V). If the voltage drops below this value, a critical alert/event if enabled will be gener…
1.3.6.1.4.1.2.3.51.2.22.1.5.6.1.33ColumnbladeSensor6VoltHighWarningread-onlymandatoryVoltage warning threshold reading for IPMI blades expressed in Volts(V). If the voltage rises above this value, a critical alert/event if enabled will be gener…
1.3.6.1.4.1.2.3.51.2.22.1.5.6.1.34ColumnbladeSensor6VoltLowWarningread-onlymandatoryVoltage warning threshold reading for IPMI blades expressed in Volts(V). If the voltage drops below this value, a critical alert/event if enabled will be gener…
1.3.6.1.4.1.2.3.51.2.22.1.5.6.1.35ColumnbladeSensor7VoltHighWarningread-onlymandatoryVoltage warning threshold reading for IPMI blades expressed in Volts(V). If the voltage rises above this value, a critical alert/event if enabled will be gener…
1.3.6.1.4.1.2.3.51.2.22.1.5.6.1.36ColumnbladeSensor7VoltLowWarningread-onlymandatoryVoltage warning threshold reading for IPMI blades expressed in Volts(V). If the voltage drops below this value, a critical alert/event if enabled will be gener…
1.3.6.1.4.1.2.3.51.2.22.1.5.6.1.37ColumnbladeSensor8VoltHighWarningread-onlymandatoryVoltage warning threshold reading for IPMI blades expressed in Volts(V). If the voltage rises above this value, a critical alert/event if enabled will be gener…
1.3.6.1.4.1.2.3.51.2.22.1.5.6.1.38ColumnbladeSensor8VoltLowWarningread-onlymandatoryVoltage warning threshold reading for IPMI blades expressed in Volts(V). If the voltage drops below this value, a critical alert/event if enabled will be gener…
1.3.6.1.4.1.2.3.51.2.22.1.5.6.1.39ColumnbladeSensor9VoltHighWarningread-onlymandatoryVoltage warning threshold reading for IPMI blades expressed in Volts(V). If the voltage rises above this value, a critical alert/event if enabled will be gener…
1.3.6.1.4.1.2.3.51.2.22.1.5.6.1.40ColumnbladeSensor9VoltLowWarningread-onlymandatoryVoltage warning threshold reading for IPMI blades expressed in Volts(V). If the voltage drops below this value, a critical alert/event if enabled will be gener…
1.3.6.1.4.1.2.3.51.2.22.1.5.6.1.41ColumnbladeSensor10VoltHighWarningread-onlymandatoryVoltage warning threshold reading for IPMI blades expressed in Volts(V). If the voltage rises above this value, a critical alert/event if enabled will be gener…
1.3.6.1.4.1.2.3.51.2.22.1.5.6.1.42ColumnbladeSensor10VoltLowWarningread-onlymandatoryVoltage warning threshold reading for IPMI blades expressed in Volts(V). If the voltage drops below this value, a critical alert/event if enabled will be gener…
1.3.6.1.4.1.2.3.51.2.22.1.5.6.1.43ColumnbladeSensor11VoltHighWarningread-onlymandatoryVoltage warning threshold reading for IPMI blades expressed in Volts(V). If the voltage rises above this value, a critical alert/event if enabled will be gener…
1.3.6.1.4.1.2.3.51.2.22.1.5.6.1.44ColumnbladeSensor11VoltLowWarningread-onlymandatoryVoltage warning threshold reading for IPMI blades expressed in Volts(V). If the voltage drops below this value, a critical alert/event if enabled will be gener…
1.3.6.1.4.1.2.3.51.2.22.1.5.6.1.45ColumnbladeSensor12VoltHighWarningread-onlymandatoryVoltage warning threshold reading for IPMI blades expressed in Volts(V). If the voltage rises above this value, a critical alert/event if enabled will be gener…
1.3.6.1.4.1.2.3.51.2.22.1.5.6.1.46ColumnbladeSensor12VoltLowWarningread-onlymandatoryVoltage warning threshold reading for IPMI blades expressed in Volts(V). If the voltage drops below this value, a critical alert/event if enabled will be gener…
1.3.6.1.4.1.2.3.51.2.22.1.5.6.1.47ColumnbladeSensor13VoltHighWarningread-onlymandatoryVoltage warning threshold reading for IPMI blades expressed in Volts(V). If the voltage rises above this value, a critical alert/event if enabled will be gener…
1.3.6.1.4.1.2.3.51.2.22.1.5.6.1.48ColumnbladeSensor13VoltLowWarningread-onlymandatoryVoltage warning threshold reading for IPMI blades expressed in Volts(V). If the voltage drops below this value, a critical alert/event if enabled will be gener…
1.3.6.1.4.1.2.3.51.2.22.1.5.6.1.49ColumnbladeSensor14VoltHighWarningread-onlymandatoryVoltage warning threshold reading for IPMI blades expressed in Volts(V). If the voltage rises above this value, a critical alert/event if enabled will be gener…
1.3.6.1.4.1.2.3.51.2.22.1.5.6.1.50ColumnbladeSensor14VoltLowWarningread-onlymandatoryVoltage warning threshold reading for IPMI blades expressed in Volts(V). If the voltage drops below this value, a critical alert/event if enabled will be gener…
1.3.6.1.4.1.2.3.51.2.22.1.5.6.1.51ColumnbladeSensor15VoltHighWarningread-onlymandatoryVoltage warning threshold reading for IPMI blades expressed in Volts(V). If the voltage rises above this value, a critical alert/event if enabled will be gener…
1.3.6.1.4.1.2.3.51.2.22.1.5.6.1.52ColumnbladeSensor15VoltLowWarningread-onlymandatoryVoltage warning threshold reading for IPMI blades expressed in Volts(V). If the voltage drops below this value, a critical alert/event if enabled will be gener…
1.3.6.1.4.1.2.3.51.2.22.1.5.6.1.53ColumnbladeSensor16VoltHighWarningread-onlymandatoryVoltage warning threshold reading for IPMI blades expressed in Volts(V). If the voltage rises above this value, a critical alert/event if enabled will be gener…
1.3.6.1.4.1.2.3.51.2.22.1.5.6.1.54ColumnbladeSensor16VoltLowWarningread-onlymandatoryVoltage warning threshold reading for IPMI blades expressed in Volts(V). If the voltage drops below this value, a critical alert/event if enabled will be gener…
1.3.6.1.4.1.2.3.51.2.22.1.5.6.1.55ColumnbladeSensor17VoltHighWarningread-onlymandatoryVoltage warning threshold reading for IPMI blades expressed in Volts(V). If the voltage rises above this value, a critical alert/event if enabled will be gener…
1.3.6.1.4.1.2.3.51.2.22.1.5.6.1.56ColumnbladeSensor17VoltLowWarningread-onlymandatoryVoltage warning threshold reading for IPMI blades expressed in Volts(V). If the voltage drops below this value, a critical alert/event if enabled will be gener…
1.3.6.1.4.1.2.3.51.2.22.1.5.6.1.57ColumnbladeSensor18VoltHighWarningread-onlymandatoryVoltage warning threshold reading for IPMI blades expressed in Volts(V). If the voltage rises above this value, a critical alert/event if enabled will be gener…
1.3.6.1.4.1.2.3.51.2.22.1.5.6.1.58ColumnbladeSensor18VoltLowWarningread-onlymandatoryVoltage warning threshold reading for IPMI blades expressed in Volts(V). If the voltage drops below this value, a critical alert/event if enabled will be gener…
1.3.6.1.4.1.2.3.51.2.22.1.5.6.1.59ColumnbladeSensor19VoltHighWarningread-onlymandatoryVoltage warning threshold reading for IPMI blades expressed in Volts(V). If the voltage rises above this value, a critical alert/event if enabled will be gener…
1.3.6.1.4.1.2.3.51.2.22.1.5.6.1.60ColumnbladeSensor19VoltLowWarningread-onlymandatoryVoltage warning threshold reading for IPMI blades expressed in Volts(V). If the voltage drops below this value, a critical alert/event if enabled will be gener…
1.3.6.1.4.1.2.3.51.2.22.1.5.6.1.61ColumnbladeSensor20VoltHighWarningread-onlymandatoryVoltage warning threshold reading for IPMI blades expressed in Volts(V). If the voltage rises above this value, a critical alert/event if enabled will be gener…
1.3.6.1.4.1.2.3.51.2.22.1.5.6.1.62ColumnbladeSensor20VoltLowWarningread-onlymandatoryVoltage warning threshold reading for IPMI blades expressed in Volts(V). If the voltage drops below this value, a critical alert/event if enabled will be gener…
1.3.6.1.4.1.2.3.51.2.22.1.5.6.1.63ColumnbladeSensor21VoltHighWarningread-onlymandatoryVoltage warning threshold reading for IPMI blades expressed in Volts(V). If the voltage rises above this value, a critical alert/event if enabled will be gener…
1.3.6.1.4.1.2.3.51.2.22.1.5.6.1.64ColumnbladeSensor21VoltLowWarningread-onlymandatoryVoltage warning threshold reading for IPMI blades expressed in Volts(V). If the voltage drops below this value, a critical alert/event if enabled will be gener…
1.3.6.1.4.1.2.3.51.2.22.1.5.6.1.65ColumnbladeSensor22VoltHighWarningread-onlymandatoryVoltage warning threshold reading for IPMI blades expressed in Volts(V). If the voltage rises above this value, a critical alert/event if enabled will be gener…
1.3.6.1.4.1.2.3.51.2.22.1.5.6.1.66ColumnbladeSensor22VoltLowWarningread-onlymandatoryVoltage warning threshold reading for IPMI blades expressed in Volts(V). If the voltage drops below this value, a critical alert/event if enabled will be gener…
1.3.6.1.4.1.2.3.51.2.22.1.5.6.1.67ColumnbladeSensor23VoltHighWarningread-onlymandatoryVoltage warning threshold reading for IPMI blades expressed in Volts(V). If the voltage rises above this value, a critical alert/event if enabled will be gener…
1.3.6.1.4.1.2.3.51.2.22.1.5.6.1.68ColumnbladeSensor23VoltLowWarningread-onlymandatoryVoltage warning threshold reading for IPMI blades expressed in Volts(V). If the voltage drops below this value, a critical alert/event if enabled will be gener…
1.3.6.1.4.1.2.3.51.2.22.1.5.6.1.69ColumnbladeSensor24VoltHighWarningread-onlymandatoryVoltage warning threshold reading for IPMI blades expressed in Volts(V). If the voltage rises above this value, a critical alert/event if enabled will be gener…
1.3.6.1.4.1.2.3.51.2.22.1.5.6.1.70ColumnbladeSensor24VoltLowWarningread-onlymandatoryVoltage warning threshold reading for IPMI blades expressed in Volts(V). If the voltage drops below this value, a critical alert/event if enabled will be gener…
1.3.6.1.4.1.2.3.51.2.22.1.5.6.1.71ColumnbladeSensor25VoltHighWarningread-onlymandatoryVoltage warning threshold reading for IPMI blades expressed in Volts(V). If the voltage rises above this value, a critical alert/event if enabled will be gener…
1.3.6.1.4.1.2.3.51.2.22.1.5.6.1.72ColumnbladeSensor25VoltLowWarningread-onlymandatoryVoltage warning threshold reading for IPMI blades expressed in Volts(V). If the voltage drops below this value, a critical alert/event if enabled will be gener…
1.3.6.1.4.1.2.3.51.2.22.1.5.6.1.73ColumnbladeSensor26VoltHighWarningread-onlymandatoryVoltage warning threshold reading for IPMI blades expressed in Volts(V). If the voltage rises above this value, a critical alert/event if enabled will be gener…
1.3.6.1.4.1.2.3.51.2.22.1.5.6.1.74ColumnbladeSensor26VoltLowWarningread-onlymandatoryVoltage warning threshold reading for IPMI blades expressed in Volts(V). If the voltage drops below this value, a critical alert/event if enabled will be gener…
1.3.6.1.4.1.2.3.51.2.22.1.5.6.1.75ColumnbladeSensor27VoltHighWarningread-onlymandatoryVoltage warning threshold reading for IPMI blades expressed in Volts(V). If the voltage rises above this value, a critical alert/event if enabled will be gener…
1.3.6.1.4.1.2.3.51.2.22.1.5.6.1.76ColumnbladeSensor27VoltLowWarningread-onlymandatoryVoltage warning threshold reading for IPMI blades expressed in Volts(V). If the voltage drops below this value, a critical alert/event if enabled will be gener…
1.3.6.1.4.1.2.3.51.2.22.1.5.6.1.77ColumnbladeSensor28VoltHighWarningread-onlymandatoryVoltage warning threshold reading for IPMI blades expressed in Volts(V). If the voltage rises above this value, a critical alert/event if enabled will be gener…
1.3.6.1.4.1.2.3.51.2.22.1.5.6.1.78ColumnbladeSensor28VoltLowWarningread-onlymandatoryVoltage warning threshold reading for IPMI blades expressed in Volts(V). If the voltage drops below this value, a critical alert/event if enabled will be gener…
1.3.6.1.4.1.2.3.51.2.22.1.5.6.1.79ColumnbladeSensor29VoltHighWarningread-onlymandatoryVoltage warning threshold reading for IPMI blades expressed in Volts(V). If the voltage rises above this value, a critical alert/event if enabled will be gener…
1.3.6.1.4.1.2.3.51.2.22.1.5.6.1.80ColumnbladeSensor29VoltLowWarningread-onlymandatoryVoltage warning threshold reading for IPMI blades expressed in Volts(V). If the voltage drops below this value, a critical alert/event if enabled will be gener…
1.3.6.1.4.1.2.3.51.2.22.1.5.6.1.81ColumnbladeSensor30VoltHighWarningread-onlymandatoryVoltage warning threshold reading for IPMI blades expressed in Volts(V). If the voltage rises above this value, a critical alert/event if enabled will be gener…
1.3.6.1.4.1.2.3.51.2.22.1.5.6.1.82ColumnbladeSensor30VoltLowWarningread-onlymandatoryVoltage warning threshold reading for IPMI blades expressed in Volts(V). If the voltage drops below this value, a critical alert/event if enabled will be gener…
1.3.6.1.4.1.2.3.51.2.22.1.6NodebladePowerRestart
1.3.6.1.4.1.2.3.51.2.22.1.6.1TablebladePowerRestartTablenot-accessiblemandatoryTable of blade remote power control information. Contains power on/off enablement status for each blade.
1.3.6.1.4.1.2.3.51.2.22.1.6.1.1RowbladePowerRestartEntrynot-accessiblemandatoryBlade power restart table entry
1.3.6.1.4.1.2.3.51.2.22.1.6.1.1.1ColumnpowerRestartIndexread-onlymandatoryBlade power restart table index.
1.3.6.1.4.1.2.3.51.2.22.1.6.1.1.2ColumnpowerRestartBladeIdread-onlymandatoryThe numeric blade ID.
1.3.6.1.4.1.2.3.51.2.22.1.6.1.1.3ColumnpowerRestartBladeExistsread-onlymandatoryIndicates whether the server blade specified exists or not.
1.3.6.1.4.1.2.3.51.2.22.1.6.1.1.4ColumnpowerRestartBladePowerStateread-onlymandatoryIndicates the power state of the blade specified. If the state cannot be determined, the unknown(255) is returned.
1.3.6.1.4.1.2.3.51.2.22.1.6.1.1.5ColumnpowerRestartBladeHealthStateread-onlymandatoryThe system health state for the blade. Unknown: Blade is in an undefined state. Good: Blade is operating normally. Warning: One or more outstanding warnings ex…
1.3.6.1.4.1.2.3.51.2.22.1.6.1.1.6ColumnpowerRestartBladeNameread-onlymandatoryThe name of the blade as a null terminated string.
1.3.6.1.4.1.2.3.51.2.22.1.6.1.1.7ColumnpowerOnOffBladeread-writemandatoryControl the power state of a specific blade. Off: Power Off Blade. On: Power On Blade. Softoff: Shut Down OS and Power Off Blade. This operation is not support…
1.3.6.1.4.1.2.3.51.2.22.1.6.1.1.8ColumnrestartBladeread-writemandatoryRestart a blade. NOTE: Value returned for the GET command is meaningless for this MIB object.
1.3.6.1.4.1.2.3.51.2.22.1.6.1.1.9ColumnrestartBladeSMPread-writemandatoryRestart a blade's system management processor. NOTE: Value returned for the GET command is meaningless for this MIB object.
1.3.6.1.4.1.2.3.51.2.22.1.6.1.1.10ColumnrestartBladeNMIread-writemandatoryIssue an NMI to the blade. This option is not supported on all blades. NOTE: Value returned for the GET command is meaningless for this MIB object.
1.3.6.1.4.1.2.3.51.2.22.1.6.1.1.11ColumnrestartBladeClearNVRAMread-writemandatoryRestart a blade and set NVRAM to default values. This option is not supported on all blades. NOTE: Value returned for the GET command is meaningless for this M…
1.3.6.1.4.1.2.3.51.2.22.1.6.1.1.12ColumnrestartBladeInvokeDiagsread-writemandatoryRestart a blade and boot into diagnostic mode. This option is not supported on all blades. NOTE: Value returned for the GET command is meaningless for this MIB…
1.3.6.1.4.1.2.3.51.2.22.1.6.1.1.13ColumnrestartBladeInvokeDiagsFromDefaultBootListread-writemandatoryRestart a blade and boot into diagnostic mode from Default Boot List as defined on the blade. This option is not supported on all blades. NOTE: Value returned …
1.3.6.1.4.1.2.3.51.2.22.1.6.1.1.14ColumnrestartBladeToSMSBootMenuread-writedeprecatedRestart a blade to SMS boot menu. This option is not supported on all blades, and at the time of this MIB definition was only supported on POWER blades. This o…
1.3.6.1.4.1.2.3.51.2.22.1.6.1.1.15ColumnbladePowerEnableSMSBootMenuread-writemandatoryEnables/disables a blade restart to the SMS boot menu. Setting this object to 'enable(1)' will cause a reboot of the node to the SMS menu. This option is not s…
1.3.6.1.4.1.2.3.51.2.22.1.7NodebladeConfiguration
1.3.6.1.4.1.2.3.51.2.22.1.7.1TablebladeConfigurationTablenot-accessiblemandatoryTable of blade configuration information. Contains boot mode and auto power on/off settings for each blade.
1.3.6.1.4.1.2.3.51.2.22.1.7.1.1RowbladeConfigurationEntrynot-accessiblemandatoryBlade configuration table entry
1.3.6.1.4.1.2.3.51.2.22.1.7.1.1.1ColumnconfigurationIndexread-onlymandatoryBlade configuration table index.
1.3.6.1.4.1.2.3.51.2.22.1.7.1.1.2ColumnconfigurationBladeIdread-onlymandatoryThe numeric blade ID.
1.3.6.1.4.1.2.3.51.2.22.1.7.1.1.3ColumnconfigurationBladeExistsread-onlymandatoryIndicates whether the server blade specified exists or not.
1.3.6.1.4.1.2.3.51.2.22.1.7.1.1.4ColumnconfigurationBladePowerStateread-onlymandatoryIndicates the power state of the blade specified.
1.3.6.1.4.1.2.3.51.2.22.1.7.1.1.5ColumnconfigurationBladeNameread-writemandatoryThe name of the blade as a null terminated string.
1.3.6.1.4.1.2.3.51.2.22.1.7.1.1.7ColumnconfigurationBladeActiveBootModeread-onlymandatoryIndicates the active copy of the firmware from which the blade is booting. NOTE: Some blades do not support the automatic boot recovery. It displays 'notApplic…
1.3.6.1.4.1.2.3.51.2.22.1.7.1.1.8ColumnconfigurationBladePendingBootModeread-writemandatoryIndicates the copy of the firmware from which the blade will boot after the next reboot. NOTE: Some blades do not support the automatic boot recovery. It displ…
1.3.6.1.4.1.2.3.51.2.22.1.7.1.1.9ColumnconfigurationBladeAutoPowerOnread-writemandatoryBlade auto-power on policy. - restore: blade will be powered on which were previously on. - auto: blade will automatically be powered on when power is applied …
1.3.6.1.4.1.2.3.51.2.22.1.7.1.1.10ColumnconfigurationBladePowerOnRestartDelayread-writemandatoryRestart delay (in seconds) when power is applied to a blade.
1.3.6.1.4.1.2.3.51.2.22.1.7.2NodebladePowerManagementPolicy
1.3.6.1.4.1.2.3.51.2.22.1.7.2.1ScalarpowerManagementPolicyread-writemandatoryPower Module Redundancy Intended for a single power source into the chassis where each Power Module is on its own dedicated circuit. Maximum power is limited t…
1.3.6.1.4.1.2.3.51.2.22.1.7.2.3ScalaracousticModeread-writemandatoryAcoustic mode setting for thermal conditions. A setting of disabled (0), disables this feature. A setting of acoustic-quiet-level1 (5) is the least restrictive…
1.3.6.1.4.1.2.3.51.2.22.1.10NodebladeBootCountPowerOnTime
1.3.6.1.4.1.2.3.51.2.22.1.10.1TablebladeBootCountPowerOnTimeTablenot-accessiblemandatoryTable per blade of the number of boots for the blade and the number of seconds the blade has been powered on.
1.3.6.1.4.1.2.3.51.2.22.1.10.1.1RowbladeBootCountPowerOnTimeEntrynot-accessiblemandatoryThe number of boots for the blade and the number of seconds the blade has been powered on.
1.3.6.1.4.1.2.3.51.2.22.1.10.1.1.1ColumnbootCountPowerOnTimeBladeIndexread-onlymandatoryBlade boot count/Power On Time table index.
1.3.6.1.4.1.2.3.51.2.22.1.10.1.1.2ColumnbootCountPowerOnTimeBladeIdread-onlymandatoryThe numeric blade ID.
1.3.6.1.4.1.2.3.51.2.22.1.10.1.1.3ColumnbootCountPowerOnTimeBootsread-writemandatoryBlade Boot Count. If there is no blade in the given slot then this value is undefined. Writing this value resets the Boot Count to zero.
1.3.6.1.4.1.2.3.51.2.22.1.10.1.1.4ColumnbootCountPowerOnTimeSecsread-writemandatoryBlade Power On Time in seconds. If there is no blade in the given slot then this value is undefined. Writing this value resets the Power On Time to zero.
1.3.6.1.4.1.2.3.51.2.22.1.11ScalarbladeVlanIdread-writemandatoryThis is the virtual LAN ID for the internal management network between the MM and the blade system management processors (BSMPs). The range of valid VLAN ID's …
1.3.6.1.4.1.2.3.51.2.22.1.12NodebladeNetworkConfiguration
1.3.6.1.4.1.2.3.51.2.22.1.12.5TablebladeIPv4ConfigTablenot-accessiblemandatoryTable of all blades' network interfaces.
1.3.6.1.4.1.2.3.51.2.22.1.12.5.1RowbladeIPv4ConfigEntrynot-accessiblemandatoryBlade configuration table entry
1.3.6.1.4.1.2.3.51.2.22.1.12.5.1.1ColumnbladeIPv4ConfigIndexread-onlymandatoryThe blade's slot number.
1.3.6.1.4.1.2.3.51.2.22.1.12.5.1.2ColumnbladeIPv4ConfigPortIndexread-onlymandatoryThe physical port number of the given entry.
1.3.6.1.4.1.2.3.51.2.22.1.12.5.1.3ColumnbladeIPv4ConfigPortLabelread-onlymandatoryShow string label that identifies the interface.
1.3.6.1.4.1.2.3.51.2.22.1.12.5.1.4ColumnbladeIPv4ConfigPhysicalLinkStatusread-onlymandatoryIndicates whether this network interface port is up or down. If this network interface doesn't support up/down, show 'notApplicable(255)'.
1.3.6.1.4.1.2.3.51.2.22.1.12.5.1.5ColumnbladeIPv4ConfigPhysicalLinkStateread-writemandatoryConfiguration object for requesting the physical port to be either, down(0), up(1) or loopback(2). To get the current status of a physical port, use the object…
1.3.6.1.4.1.2.3.51.2.22.1.12.5.1.6ColumnbladeIPv4ConfigIPAddrread-writemandatoryShow/modify current IP address of the blade network interface. Note that only if the bladeIPv4ConfigPhysicalLinkStatus is 'up(1)' and the bladeIPv4ConfigDHCPEn…
1.3.6.1.4.1.2.3.51.2.22.1.12.5.1.7ColumnbladeIPv4ConfigSubnetMaskread-writemandatoryShow or modifie current subnet mask of the blade network interface. Note that only if the bladeIPv4ConfigPhysicalLinkStatus is 'up(1)' and the bladeIPv4ConfigD…
1.3.6.1.4.1.2.3.51.2.22.1.12.5.1.8ColumnbladeIPv4ConfigGatewayAddrread-writemandatoryShow or modify current IP gateway of the blade network interface. Note that only if the bladeIPv4ConfigPhysicalLinkStatus is 'up(1)' and the bladeIPv4ConfigDHC…
1.3.6.1.4.1.2.3.51.2.22.1.12.5.1.9ColumnbladeIPv4ConfigVlanIdread-writemandatoryThis is the Virtual LAN ID for supported network interface cards (NICs). The range of valid VLAN ID's is 0 to 4095.
1.3.6.1.4.1.2.3.51.2.22.1.12.5.1.10ColumnbladeIPv4ConfigDHCPEnableread-writemandatoryIP config method on the blade network interface to modify mode to static IP, DHCP and 'try DHCP then try static'. If this network interface doesn't support DHC…
1.3.6.1.4.1.2.3.51.2.22.1.12.5.1.11ColumnbladeIPv4ConfigMACAddrread-onlymandatoryShow the blade network interface MAC address. If this network interface doesn't support MAC, show 'notApplicable'.
1.3.6.1.4.1.2.3.51.2.22.1.12.10NodebladeIPv6Config
1.3.6.1.4.1.2.3.51.2.22.1.12.10.1TablebladeIPv6ConfigTablenot-accessiblemandatoryA table of IPv6 configuration options for blades. NOTE: This MIB object is not applicable to blades that do not support IPv6.
1.3.6.1.4.1.2.3.51.2.22.1.12.10.1.1RowbladeIPv6ConfigEntrynot-accessiblemandatoryIPv6 configuration options for a blade. NOTE: This MIB object is not applicable to blades that do not support IPv6.
1.3.6.1.4.1.2.3.51.2.22.1.12.10.1.1.1ColumnbladeIPv6ConfigIndexread-onlymandatoryThe blade's slot number
1.3.6.1.4.1.2.3.51.2.22.1.12.10.1.1.2ColumnbladeIPv6ConfigPortIndexread-onlymandatoryThe physical port number of the given entry
1.3.6.1.4.1.2.3.51.2.22.1.12.10.1.1.3ColumnbladeIPv6ConfigEnabledread-writemandatoryEnables/Disables IPv6 support on the blade.
1.3.6.1.4.1.2.3.51.2.22.1.12.10.1.1.4ColumnbladeIPv6ConfigStaticread-writemandatoryEnables/Disables IPv6 static configuration support on the blade.
1.3.6.1.4.1.2.3.51.2.22.1.12.10.1.1.5ColumnbladeDHCPv6ConfigEnabledread-writemandatoryEnables/Disables DHCPv6 address configuration support on the blade.
1.3.6.1.4.1.2.3.51.2.22.1.12.10.1.1.6ColumnbladeIPv6ConfigStatelessEnabledread-writemandatoryEnables/Disables IPv6 stateless auto-configuration support on the blade.
1.3.6.1.4.1.2.3.51.2.22.1.12.10.2TablebladeIPv6AddressTablenot-accessiblemandatoryA table of assigned IPv6 addresses for blades. NOTE: This MIB object is not applicable to blades that do not support IPv6.
1.3.6.1.4.1.2.3.51.2.22.1.12.10.2.1RowbladeIPv6AddressEntrynot-accessiblemandatoryThe assigned IPv6 address for a given blade. NOTE: This MIB object is not applicable to blades that do not support IPv6.
1.3.6.1.4.1.2.3.51.2.22.1.12.10.2.1.1ColumnbladeIPv6AddressIndexread-onlymandatoryThe blade's slot number.
1.3.6.1.4.1.2.3.51.2.22.1.12.10.2.1.2ColumnbladeIPv6AddressPortIndexread-onlymandatoryThe blade's physical port number for the given entry.
1.3.6.1.4.1.2.3.51.2.22.1.12.10.2.1.3ColumnbladeIPv6AddressEntryIndexread-onlymandatoryThe blade's address entry index.
1.3.6.1.4.1.2.3.51.2.22.1.12.10.2.1.4ColumnbladeIPv6AddressTyperead-onlymandatoryThe address type.
1.3.6.1.4.1.2.3.51.2.22.1.12.10.2.1.5ColumnbladeIPv6Addressread-writemandatoryThe assigned IPv6 address. Note: 'write' is for static ipv6 only.
1.3.6.1.4.1.2.3.51.2.22.1.12.10.2.1.6ColumnbladeIPv6AddressPrefixLenread-writemandatoryThe prefix length for the given address. Note: 'write' is for static ipv6 only.
1.3.6.1.4.1.2.3.51.2.22.1.12.10.2.1.7ColumnbladeIPv6AddressDefaultRouteread-writemandatoryThe default route used for the given address. Note: 'write' is for static ipv6 only.
1.3.6.1.4.1.2.3.51.2.22.1.13TablebladeBayDataTablenot-accessiblemandatoryTable of blade bay data (BBD) information.
1.3.6.1.4.1.2.3.51.2.22.1.13.1RowbladeBayDataEntrynot-accessiblemandatoryBlade bay data (BBD) table entry.
1.3.6.1.4.1.2.3.51.2.22.1.13.1.1ColumnbayDataIndexread-onlymandatoryBlade bay data (BBD) table index.
1.3.6.1.4.1.2.3.51.2.22.1.13.1.2ColumnbayDataBladeIdread-onlymandatoryThe numeric blade ID.
1.3.6.1.4.1.2.3.51.2.22.1.13.1.3ColumnbayDataBladeExistsread-onlymandatoryIndicates whether the server blade specified exists or not.
1.3.6.1.4.1.2.3.51.2.22.1.13.1.4ColumnbayDataBladePowerStateread-onlymandatoryIndicates the power state of the blade specified.
1.3.6.1.4.1.2.3.51.2.22.1.13.1.5ColumnbayDataBladeNameread-onlymandatoryThe name of the blade as a null terminated string.
1.3.6.1.4.1.2.3.51.2.22.1.13.1.6ColumnbayDataread-writemandatoryA null terminated string that defines the Blade Bay Data (BBD). This data is pushed to the blade's BSMP and SMBIOS structures, where it can used by the blade's…
1.3.6.1.4.1.2.3.51.2.22.1.13.1.7ColumnbayDataBladeStatusread-onlymandatoryThis shows Blade Bay Data (BBD) status. 0 means the blade fully supports BBD; 1 means that the blade's BIOS does not support BBD; 2 means that there is no blad…
1.3.6.1.4.1.2.3.51.2.22.1.14NodebladeSPEthOverUSBInterface
1.3.6.1.4.1.2.3.51.2.22.1.14.1TablespEthOverUSBInterfaceTablenot-accessiblemandatoryTable of blade Service Processor's Ethernet over USB interface.
1.3.6.1.4.1.2.3.51.2.22.1.14.1.1RowspEthOverUSBInterfaceEntrynot-accessiblemandatoryBlade Service Processor's Ethernet over USB interface entry.
1.3.6.1.4.1.2.3.51.2.22.1.14.1.1.1ColumnspEthOverUSBInterfaceIndexread-onlymandatoryService Processor's Ethernet over USB interface table index.
1.3.6.1.4.1.2.3.51.2.22.1.14.1.1.2ColumnspEthOverUSBInterfaceBladeIdread-onlymandatoryThe numeric blade ID.
1.3.6.1.4.1.2.3.51.2.22.1.14.1.1.3ColumnspEthOverUSBInterfaceBladeExistsread-onlymandatoryIndicates whether the blade specified exists or not.
1.3.6.1.4.1.2.3.51.2.22.1.14.1.1.6ColumnspEthOverUSBInterfaceBladeNameread-onlymandatoryThe name of the blade as a null terminated string.
1.3.6.1.4.1.2.3.51.2.22.1.14.1.1.9ColumnspEthOverUSBInterfaceEnableread-writemandatoryThis object allows the user to view the status of, and enable or disable, a blade Service Processor's command interface on Ethernet-over-USB. NOTE: If the blad…
1.3.6.1.4.1.2.3.51.2.22.1.15TablebootDeviceInfoTablenot-accessiblemandatoryTable of blade boot device information. Contains info for the boot devices for each blade.
1.3.6.1.4.1.2.3.51.2.22.1.15.1RowbootDeviceInfoEntrynot-accessiblemandatoryBoot device entry
1.3.6.1.4.1.2.3.51.2.22.1.15.1.1ColumnbootInfoTopologyIndexread-onlymandatoryThe unique identifier for a node containing boot devices in this table. The chassis and each installed component is represented by a hardware topology tree, wh…
1.3.6.1.4.1.2.3.51.2.22.1.15.1.2ColumnbootDeviceIndexread-onlymandatoryAn index for the boot device for the given topology id.
1.3.6.1.4.1.2.3.51.2.22.1.15.1.3ColumnbootDeviceIdread-onlymandatoryThe device Id of the boot device.
1.3.6.1.4.1.2.3.51.2.22.1.15.1.4ColumnbootDeviceActiveread-onlymandatorySpecifies whether the boot device is active.
1.3.6.1.4.1.2.3.51.2.22.1.15.1.5ColumnbootDevicePresenceread-onlymandatorySpecifies whether the boot device is present.
1.3.6.1.4.1.2.3.51.2.22.1.15.1.6ColumnbootDeviceLabelread-onlymandatoryThe device label of the boot device.
1.3.6.1.4.1.2.3.51.2.22.1.15.1.7ColumnbootDeviceUserLabelread-onlymandatoryThe user label of the boot device.
1.3.6.1.4.1.2.3.51.2.22.1.15.1.8ColumnbootDeviceOrderread-onlymandatoryThe sequence number in boot order of the boot device. 0 specifies this device is not in the boot sequence.
1.3.6.1.4.1.2.3.51.2.22.1.16TablebootSequenceInfoTablenot-accessiblemandatoryTable of blade boot sequence information. Contains the boot sequence information for each blade.
1.3.6.1.4.1.2.3.51.2.22.1.16.1RowbootSequenceInfoEntrynot-accessiblemandatoryBoot sequence entry
1.3.6.1.4.1.2.3.51.2.22.1.16.1.1ColumnbootSequenceInfoTopologyIndexread-onlymandatoryThe unique identifier for a row in this table. The chassis and each installed component is represented by a hardware topology tree, where each node in the tree…
1.3.6.1.4.1.2.3.51.2.22.1.16.1.2ColumnbootSequenceInfoMaxBootDevicesread-onlymandatoryThe maximum number of boot devices.
1.3.6.1.4.1.2.3.51.2.22.1.16.1.3ColumnbootSequenceInfoBootSequenceread-writemandatoryA blank delimited string of device ids in the order of the boot sequence. For example, 00000001 00000002 00000005. Note that the boot sequence list can change …
1.3.6.1.4.1.2.3.51.2.22.3NodeswitchModule
1.3.6.1.4.1.2.3.51.2.22.3.1NodeswitchModuleControl
1.3.6.1.4.1.2.3.51.2.22.3.1.1TablesmControlTablenot-accessiblemandatorySwitch module control table.
1.3.6.1.4.1.2.3.51.2.22.3.1.1.1RowsmControlEntrynot-accessiblemandatorySwitch module control table entry
1.3.6.1.4.1.2.3.51.2.22.3.1.1.1.1ColumnsmControlIndexread-onlymandatorySwitch module control table index.
1.3.6.1.4.1.2.3.51.2.22.3.1.1.1.2ColumnswitchModuleControlIdread-onlymandatoryThe switch module numeric identifier.
1.3.6.1.4.1.2.3.51.2.22.3.1.1.1.3ColumnsmPostResultsAvailableread-onlymandatoryDescribes whether the switch module POST diagnostic result value contained in the smPostResultsValue is valid.
1.3.6.1.4.1.2.3.51.2.22.3.1.1.1.4ColumnsmPostResultsValueread-onlymandatoryThe range of values and meanings are as follows: 0x00 - 0x7F ( 0 - 127) Base internal functions 0x80 - 0x9F (128 - 159) Internal interface failures 0xA0 - 0xAF…
1.3.6.1.4.1.2.3.51.2.22.3.1.1.1.5ColumnswitchModuleMemDiagEnableDisableread-writedeprecatedSwitch module memory diagnostics enabled or disabled. NOTE: The numeric values for the enumerations for enabled and disabled are non-traditional (i.e. - 0 and …
1.3.6.1.4.1.2.3.51.2.22.3.1.1.1.6ColumnsmCfgCtrlEnableDisableread-writemandatorySwitch module configuration control. When set to enabled, only the MM can manage the module. This MIB object can not be set, if MM grants switch module the Pro…
1.3.6.1.4.1.2.3.51.2.22.3.1.1.1.7ColumnsmExtEthPortsEnableDisableread-writemandatorySwitch module non-management ethernet ports enabled or disabled. This MIB object can not be set, if MM grants switch module the Protected Mode permission. This…
1.3.6.1.4.1.2.3.51.2.22.3.1.1.1.9ColumnsmCfgCtrlOnResetEnableDisableread-writemandatorySwitch module configuration control on resets (default and unsolicited). When set to enabled, the factory default IP configuration will become active when the …
1.3.6.1.4.1.2.3.51.2.22.3.1.1.1.15ColumnsmHealthStateread-onlymandatoryThe health state for the switch module. 0 = unknown, 1 = good, 2 = warning, 3 = bad.
1.3.6.1.4.1.2.3.51.2.22.3.1.1.1.16ColumnsmPMStateread-onlymandatoryThe Protected Mode Status for the switch module. standby- Protected Mode capability exists on the IOM but has not been activated on the switch module or the MM…
1.3.6.1.4.1.2.3.51.2.22.3.1.1.1.17ColumnsmPMCtrlEnableDisableread-writemandatoryMM Protected Mode permission for the switch module. disabled - allow MM to disable Protected Mode Permission for the switch module. enabled - allow MM to grant…
1.3.6.1.4.1.2.3.51.2.22.3.1.1.1.18ColumnsmIOCompatibilityread-onlymandatoryThe compatibility status for the I/O module. The possible values and their meanings are as follows: Unknown: This indicates a communication error for the I/O m…
1.3.6.1.4.1.2.3.51.2.22.3.1.2TablesmPingTablenot-accessiblemandatoryAllows pinging one of the active assigned addresses of an I/O module. NOTE: This table is not applicable to modules that are running in Stacking Mode and IP co…
1.3.6.1.4.1.2.3.51.2.22.3.1.2.1RowsmPingEntrynot-accessiblemandatoryRepresents a single address that can be pinged
1.3.6.1.4.1.2.3.51.2.22.3.1.2.1.1ColumnsmPingIndexread-onlymandatoryThe switch module's slot number
1.3.6.1.4.1.2.3.51.2.22.3.1.2.1.2ColumnsmPingAddressEntryIndexread-onlymandatoryThe switch module's address entry index
1.3.6.1.4.1.2.3.51.2.22.3.1.2.1.3ColumnsmPingAddressread-onlymandatoryThe switch module's IPv4 or IPv6 address
1.3.6.1.4.1.2.3.51.2.22.3.1.2.1.4ColumnsmPingAddressExecuteread-writemandatoryPings the given IP address. NOTE: The GET operation for this object is meaningless.
1.3.6.1.4.1.2.3.51.2.22.3.1.7TablesmPowerRestartTablenot-accessiblemandatorySwitch module power restart table.
1.3.6.1.4.1.2.3.51.2.22.3.1.7.1RowsmPowerRestartEntrynot-accessiblemandatorySwitch module power restart table entry
1.3.6.1.4.1.2.3.51.2.22.3.1.7.1.1ColumnsmPowerRestartIndexread-onlymandatorySwitch module power restart index.
1.3.6.1.4.1.2.3.51.2.22.3.1.7.1.2ColumnsmPowerRestartIdread-onlymandatoryThe switch module numeric identifier.
1.3.6.1.4.1.2.3.51.2.22.3.1.7.1.3ColumnsmSwitchExistsread-onlymandatoryIndicates whether the switch module specified exists or not.
1.3.6.1.4.1.2.3.51.2.22.3.1.7.1.5ColumnsmMACAddressread-onlymandatorySwitch module MAC address. For IOMs which are members of a stack, this field is not applicable and should be disregarded.
1.3.6.1.4.1.2.3.51.2.22.3.1.7.1.6ColumnsmIPAddressread-onlymandatoryThe switch module current IP address. If the switch module is participating in the Stacking Mode and IP Configuration is protected, then the stack management I…
1.3.6.1.4.1.2.3.51.2.22.3.1.7.1.7ColumnswitchModulePowerOnOffread-writemandatoryI/O Module power on or power off. If powering on a currently powered off I/O Module, then the I/O Module will execute a POST. The results of this POST will nee…
1.3.6.1.4.1.2.3.51.2.22.3.1.7.1.8ColumnsmResetread-writemandatoryFor the case where the switch module is currently powered on, this command will effectively power off and then power on the switch module indicated and cause i…
1.3.6.1.4.1.2.3.51.2.22.3.1.7.1.9ColumnsmResetToDefaultread-writemandatoryFor the case where the switch module is currently powered on, this command will effectively power off and then power on the switch module indicated and cause i…
1.3.6.1.4.1.2.3.51.2.22.3.1.7.1.10ColumnsmRestartAndRunStdDiagread-writemandatoryTo power cycle the selected module(s) and then run the standard diagnostic test package. NOTE: Value returned for the GET command is meaningless for this MIB o…
1.3.6.1.4.1.2.3.51.2.22.3.1.7.1.11ColumnsmRestartAndRunExtDiagread-writemandatoryTo power cycle the selected module(s) and then run the extended diagnostic test package. This option is not supported on all I/O modules. NOTE: Value returned …
1.3.6.1.4.1.2.3.51.2.22.3.1.7.1.12ColumnsmRestartAndRunFullDiagread-writemandatoryTo power cycle the selected module(s) and then run the full diagnostic test package. The full diagnostic test package may take over 5 minutes to run. This opti…
1.3.6.1.4.1.2.3.51.2.22.3.1.7.1.15ColumnsmPowerOnRestartDelayread-writemandatoryRestart delay (in seconds) when power is applied to a switch module.
1.3.6.1.4.1.2.3.51.2.22.3.1.7.1.21ColumnsmSwitchWidthread-onlymandatorySwitch module width.
1.3.6.1.4.1.2.3.51.2.22.3.1.7.1.22ColumnsmManufacturingIDread-onlymandatorySwitch module hardware VPD manufacturing ID.
1.3.6.1.4.1.2.3.51.2.22.3.1.7.1.23ColumnsmStackingModeStateread-onlymandatoryThe Stacking Mode Status for the switch module. standby - I/O module has stacking capability but is not part of a stack. member - I/O module has stacking capab…
1.3.6.1.4.1.2.3.51.2.22.3.1.7.1.24ColumnsmStackingModeInforead-onlymandatoryA string containing a text description about the details of which functions are protected for a switch module when it is in Stacking Mode as Master or Member. …
1.3.6.1.4.1.2.3.51.2.22.3.1.10TablesmIOCompatibilityTablenot-accessiblemandatorySwitch module control table.
1.3.6.1.4.1.2.3.51.2.22.3.1.10.1RowsmIOCompatibilityEntrynot-accessiblemandatorySwitch module IO compatibility table entry
1.3.6.1.4.1.2.3.51.2.22.3.1.10.1.1ColumnsmIOCompatibilityIndexread-onlymandatorySwitch module IO compatibility index.
1.3.6.1.4.1.2.3.51.2.22.3.1.10.1.2ColumnsmIOCompatibilityIdread-onlymandatoryThe switch module numeric identifier.
1.3.6.1.4.1.2.3.51.2.22.3.1.10.1.3ColumnsmIOCompatibilityModuleBayread-onlymandatoryThe modules (identified by an id string) that this I/O module can communicate with over the midplane networking fabric (i.e. a physical path exists between the…
1.3.6.1.4.1.2.3.51.2.22.3.1.10.1.4ColumnsmIOCompatibilityModulePowerread-onlymandatoryThe power state of the module specified in smIOCompatibilityModuleBay.
1.3.6.1.4.1.2.3.51.2.22.3.1.10.1.5ColumnsmIOCompatibilityModuleFabricTyperead-onlymandatoryThe I/O fabric type on the module side for the module. 'n/a' will be displayed if the corresponding channel is not populated on the module side (e.g. we are lo…
1.3.6.1.4.1.2.3.51.2.22.3.1.10.1.6ColumnsmIOCompatibilityStatusread-onlymandatoryThe compatibility status for this I/O module and the module specified in smIOCompatibilityModuleBay. The possible values are: OK: No compatibility issues n/a: …
1.3.6.1.4.1.2.3.51.2.22.3.1.10.1.7ColumnsmIOCompatibilityTargetTopologyPathread-onlymandatoryThe unique identifier for a component which communicates with this IO module. This is the same component identified with an id string in the smIOCompatibilityM…
1.3.6.1.4.1.2.3.51.2.22.3.2NodeswitchModuleConfig
1.3.6.1.4.1.2.3.51.2.22.3.2.1NodeswitchMgmtNetworkCfg
1.3.6.1.4.1.2.3.51.2.22.3.2.1.1NodeswitchCurrentNwCfg
1.3.6.1.4.1.2.3.51.2.22.3.2.1.1.1TablesmCurrentIPInfoTablenot-accessiblemandatorySwitch module current IP information. NOTE: This MIB object is not applicable to modules that are running in Stacking Mode and IP configuration is protected.
1.3.6.1.4.1.2.3.51.2.22.3.2.1.1.1.1RowsmCurrentIPInfoEntrynot-accessiblemandatorySwitch module current IP table entry. NOTE: This MIB object is not applicable to modules that are running in Stacking Mode and IP configuration is protected.
1.3.6.1.4.1.2.3.51.2.22.3.2.1.1.1.1.1ColumnsmCurrentIPInfoIndexread-onlymandatorySwitch module current IP info index. NOTE: This MIB object is not applicable to modules that are running in Stacking Mode and IP configuration is protected.
1.3.6.1.4.1.2.3.51.2.22.3.2.1.1.1.1.2ColumnsmCurrentIPInfoIdread-onlymandatoryThe switch module numeric identifier. NOTE: This MIB object is not applicable to modules that are running in Stacking Mode and IP configuration is protected.
1.3.6.1.4.1.2.3.51.2.22.3.2.1.1.1.1.3ColumnsmCurrentIPInfoExistsread-onlymandatoryIndicates whether the switch module specified exists or not. NOTE: This MIB object is not applicable to modules that are running in Stacking Mode and IP config…
1.3.6.1.4.1.2.3.51.2.22.3.2.1.1.1.1.4ColumnsmCurrentIPInfoPowerStateread-onlymandatoryIndicates whether the I/O Module specified is powered on or not. The value 'shutdownInProgress' is for the I/O Module that may take some time to transition fro…
1.3.6.1.4.1.2.3.51.2.22.3.2.1.1.1.1.6ColumnsmCurrentIPAddrread-onlymandatoryThe switch module current IP address. NOTE: This MIB object is not applicable to modules that are running in Stacking Mode and IP configuration is protected.
1.3.6.1.4.1.2.3.51.2.22.3.2.1.1.1.1.7ColumnsmCurrentSubnetMaskread-onlymandatoryThe switch module current subnet mask. NOTE: This MIB object is not applicable to modules that are running in Stacking Mode and IP configuration is protected.
1.3.6.1.4.1.2.3.51.2.22.3.2.1.1.1.1.8ColumnsmCurrentGatewayread-onlymandatoryThe switch module current IP gateway. NOTE: This MIB object is not applicable to modules that are running in Stacking Mode and IP configuration is protected.
1.3.6.1.4.1.2.3.51.2.22.3.2.1.1.1.1.9ColumnsmCurrentIPConfigMethodread-onlymandatoryThe switch module current IP configuration method. NOTE: This MIB object is not applicable to modules that are running in Stacking Mode and IP configuration is…
1.3.6.1.4.1.2.3.51.2.22.3.2.1.2NodeswitchNewNwCfg
1.3.6.1.4.1.2.3.51.2.22.3.2.1.2.1TablesmNewIPInfoTablenot-accessiblemandatorySwitch module new IP information. NOTE: This MIB object is not applicable to modules that are running in Network Address Translation (NAT) Mode or Stacking Mod…
1.3.6.1.4.1.2.3.51.2.22.3.2.1.2.1.1RowsmNewIPInfoEntrynot-accessiblemandatorySwitch module new IP configuration information table entry. NOTE: This MIB table is not applicable to modules that are running in Network Address Translation (…
1.3.6.1.4.1.2.3.51.2.22.3.2.1.2.1.1.1ColumnsmNewIPInfoIndexread-onlymandatorySwitch module new IP info index. NOTE: This MIB object is not applicable to modules that are running in Network Address Translation (NAT) Mode or Stacking Mode…
1.3.6.1.4.1.2.3.51.2.22.3.2.1.2.1.1.2ColumnsmNewIPInfoIdread-onlymandatoryThe switch module numeric identifier. NOTE: This MIB object is not applicable to modules that are running in Network Address Translation (NAT) Mode or Stacking…
1.3.6.1.4.1.2.3.51.2.22.3.2.1.2.1.1.3ColumnsmNewIPInfoExistsread-onlymandatoryIndicates whether the switch module specified exists or not. NOTE: This MIB object is not applicable to modules that are running in Network Address Translation…
1.3.6.1.4.1.2.3.51.2.22.3.2.1.2.1.1.4ColumnsmNewIPInfoPowerStateread-onlymandatoryIndicates whether the switch module specified is powered on or not. NOTE: This MIB object is not applicable to modules that are running in Network Address Tran…
1.3.6.1.4.1.2.3.51.2.22.3.2.1.2.1.1.6ColumnsmNewIPAddrread-writemandatoryThe switch module new IP address. Before setting this object to a new value, smNewIpconfigEnableDisable object must first be set to disabled. NOTE: This MIB ob…
1.3.6.1.4.1.2.3.51.2.22.3.2.1.2.1.1.7ColumnsmNewSubnetMaskread-writemandatoryThe switch module new subnet mask. Before setting this object to a new value, smNewIpconfigEnableDisable object must first be set to disabled. NOTE: This MIB o…
1.3.6.1.4.1.2.3.51.2.22.3.2.1.2.1.1.8ColumnsmNewGatewayread-writemandatoryThe switch module new IP gateway. Before setting this object to a new value, smNewIpconfigEnableDisable object must first be set to disabled. NOTE: This MIB ob…
1.3.6.1.4.1.2.3.51.2.22.3.2.1.2.1.1.9ColumnsmNewIPConfigMethodread-writemandatoryThe switch module new IP configuration method. Before setting this object to a new value, smNewIpconfigEnableDisable object must first be set to disabled. NOTE…
1.3.6.1.4.1.2.3.51.2.22.3.2.1.2.1.1.10ColumnsmNewIPConfigEnableDisableread-writemandatoryA set command enables a new IP configuration that has been previously defined. A get command indicates whether the new IP configuration information has been en…
1.3.6.1.4.1.2.3.51.2.22.3.2.1.4NodeswitchIPv6Config
1.3.6.1.4.1.2.3.51.2.22.3.2.1.4.1TablesmIPv6ConfigTablenot-accessiblemandatoryA table of IPv6 configuration options for switch modules. NOTE: This MIB object is not applicable to modules that are running in Stacking Mode and IP configura…
1.3.6.1.4.1.2.3.51.2.22.3.2.1.4.1.1RowsmIPv6ConfigEntrynot-accessiblemandatoryIPv6 configuration options for a switch module.. NOTE: This MIB object is not applicable to modules that are running in Stacking Mode and IP configuration is p…
1.3.6.1.4.1.2.3.51.2.22.3.2.1.4.1.1.1ColumnsmIPv6ConfigIndexread-onlymandatoryThe switch module's slot number
1.3.6.1.4.1.2.3.51.2.22.3.2.1.4.1.1.2ColumnsmIPv6ConfigEnabledread-writemandatoryEnables/Disables IPv6 support on the switch module.
1.3.6.1.4.1.2.3.51.2.22.3.2.1.4.1.1.3ColumnsmIPv6ConfigStaticread-writemandatoryEnables/Disables IPv6 static configuration support on the switch module.
1.3.6.1.4.1.2.3.51.2.22.3.2.1.4.1.1.4ColumnsmDHCPv6ConfigEnabledread-writemandatoryEnables/Disables DHCPv6 address configuration support on the switch module.
1.3.6.1.4.1.2.3.51.2.22.3.2.1.4.1.1.5ColumnsmIPv6ConfigStatelessEnabledread-writemandatoryEnables/Disables IPv6 stateless auto-configuration support on the switch module.
1.3.6.1.4.1.2.3.51.2.22.3.2.1.4.2TablesmIPv6AddressTablenot-accessiblemandatoryA table of assigned IPv6 addresses for switch modules. NOTE: This MIB object is not applicable to modules that are running in Stacking Mode and IP configuratio…
1.3.6.1.4.1.2.3.51.2.22.3.2.1.4.2.1RowsmIPv6AddressEntrynot-accessiblemandatoryThe assigned IPv6 address for a given switch module NOTE: This MIB object is not applicable to modules that are running in Stacking Mode and IP configuration i…
1.3.6.1.4.1.2.3.51.2.22.3.2.1.4.2.1.1ColumnsmIPv6AddressIndexread-onlymandatoryThe switch module's slot number
1.3.6.1.4.1.2.3.51.2.22.3.2.1.4.2.1.2ColumnsmIPv6AddressEntryIndexread-onlymandatoryThe switch module's address entry index
1.3.6.1.4.1.2.3.51.2.22.3.2.1.4.2.1.3ColumnsmIPv6AddressTyperead-onlymandatoryThe address type.
1.3.6.1.4.1.2.3.51.2.22.3.2.1.4.2.1.4ColumnsmIPv6Addressread-onlymandatoryThe assigned IPv6 address
1.3.6.1.4.1.2.3.51.2.22.3.2.1.4.2.1.5ColumnsmIPv6AddressPrefixLenread-onlymandatoryThe prefix length for the given address.
1.3.6.1.4.1.2.3.51.2.22.3.2.1.4.2.1.6ColumnsmIPv6AddressDefaultRouteread-onlymandatoryThe default route used for the given address
1.3.6.1.4.1.2.3.51.2.22.3.2.1.4.3TablesmIPv6StaticConfigTablenot-accessiblemandatoryAllows configuration of static IPv6 information for supported IO modules. NOTE: This MIB object is not applicable to modules that are running in Stacking Mode …
1.3.6.1.4.1.2.3.51.2.22.3.2.1.4.3.1RowsmIPv6StaticConfigEntrynot-accessiblemandatoryThe static IP address assignment information for an IO module. Once the assignement has taken place the address will show up as a row in the smIPv6AddressTable…
1.3.6.1.4.1.2.3.51.2.22.3.2.1.4.3.1.1ColumnsmIPv6StaticIndexread-onlymandatoryThe switch module's slot number
1.3.6.1.4.1.2.3.51.2.22.3.2.1.4.3.1.2ColumnsmIPv6StaticAddressread-writemandatoryThe assigned IPv6 address. NOTE: If changing with smIPv6StaticAddressPrefixLen and/or smIPv6StaticAddressDefaultRoute sending the update as a single SET comman…
1.3.6.1.4.1.2.3.51.2.22.3.2.1.4.3.1.3ColumnsmIPv6StaticAddressPrefixLenread-writemandatoryThe prefix length for the given address. NOTE: If changing with smIPv6StaticAddress and/or smIPv6StaticAddressDefaultRoute sending the update as a single SET c…
1.3.6.1.4.1.2.3.51.2.22.3.2.1.4.3.1.4ColumnsmIPv6StaticAddressDefaultRouteread-writemandatoryThe default route used for the given address NOTE: If changing with smIPv6StaticAddressPrefixLen and/or smIPv6StaticAddress sending the update as a single SET …
1.3.6.1.4.1.2.3.51.2.22.3.2.2NodeswitchPortCfg
1.3.6.1.4.1.2.3.51.2.22.3.2.2.1NodeswitchModOnePortCfg
1.3.6.1.4.1.2.3.51.2.22.3.2.2.1.1TablesmOnePortCfgTablenot-accessiblemandatorySwitch Module 1 port configuration information. NOTE: This option is not supported on all I/O modules.
1.3.6.1.4.1.2.3.51.2.22.3.2.2.1.1.1RowsmOnePortCfgEntrynot-accessiblemandatorySwitch Module 1 port configuration information table entry
1.3.6.1.4.1.2.3.51.2.22.3.2.2.1.1.1.1ColumnsmOnePortCfgIndexread-onlymandatorySwitch Module 1 port sequence index.
1.3.6.1.4.1.2.3.51.2.22.3.2.2.1.1.1.2ColumnsmOnePortCfgLabelread-onlymandatorySwitch Module 1 port label
1.3.6.1.4.1.2.3.51.2.22.3.2.2.1.1.1.3ColumnsmOnePortCfgTyperead-onlymandatorySwitch Module 1 port type: External port: This port is connected to external device and is for data traffic. External management port: This port is solely for …
1.3.6.1.4.1.2.3.51.2.22.3.2.2.1.1.1.4ColumnsmOnePortCfgLinkSettingread-writemandatoryCurrent port link setting for Switch Module 1.
1.3.6.1.4.1.2.3.51.2.22.3.2.2.1.1.1.5ColumnsmOnePortCfgLinkStateread-onlymandatoryCurrent port link state of Switch Module 1.
1.3.6.1.4.1.2.3.51.2.22.3.2.2.1.1.1.6ColumnsmOnePortCfgSpeedSettingread-writemandatorySet the port speed using the data rate and duplex value. For examples: 100mh: 100 Mbps in Half Duplex; 10gf: 10 Gbps in Full Duplex; auto: The working speed of…
1.3.6.1.4.1.2.3.51.2.22.3.2.2.1.1.1.7ColumnsmOnePortCfgSpeedStatusread-onlymandatoryCurrent port speed of Switch Module 1.
1.3.6.1.4.1.2.3.51.2.22.3.2.2.1.1.1.8ColumnsmOnePortCfgAvailSpeedsread-onlymandatoryAvailable speed setting per port for Switch Module 1. If there is more than one setting, the speeds are separated by a comma and then a space.
1.3.6.1.4.1.2.3.51.2.22.3.2.2.1.1.1.9ColumnsmOnePortCfgMediaread-onlymandatoryPort media type of Switch Module 1.
1.3.6.1.4.1.2.3.51.2.22.3.2.2.1.1.1.10ColumnsmOnePortCfgProtocolread-onlymandatoryPort protocol of Switch Module 1.
1.3.6.1.4.1.2.3.51.2.22.3.2.2.1.1.1.11ColumnsmOnePortCfgWidthread-onlymandatoryThe width of the port in terms of how many combined cables are present for Switch Module 1. A value of 0 indicates this field is not applicable to the switch p…
1.3.6.1.4.1.2.3.51.2.22.3.2.2.1.1.1.12ColumnsmOnePortCfgCableLengthread-onlymandatoryThe length (in meters) of the cable supported by this port for Switch Module 1. A value of 0 indicates this field is not applicable to the switch ports.
1.3.6.1.4.1.2.3.51.2.22.3.2.2.1.1.1.13ColumnsmOnePortCfgCableTyperead-onlymandatoryExternal cable type for this port, for example, active copper or passive fiber.
1.3.6.1.4.1.2.3.51.2.22.3.2.2.1.1.1.14ColumnsmOnePortCfgVendorNameread-onlymandatoryThe cable manufacturer.
1.3.6.1.4.1.2.3.51.2.22.3.2.2.1.1.1.15ColumnsmOnePortCfgCompatibilityread-onlymandatoryCompatibility of the external cable that is plugged into the port.
1.3.6.1.4.1.2.3.51.2.22.3.2.2.1.1.1.16ColumnsmOnePortCfgDataRateread-onlymandatoryData rate supported for this port.
1.3.6.1.4.1.2.3.51.2.22.3.2.2.2NodeswitchModTwoPortCfg
1.3.6.1.4.1.2.3.51.2.22.3.2.2.2.1TablesmTwoPortCfgTablenot-accessiblemandatorySwitch Module 2 port configuration information. Note: This option is not supported on all I/O modules.
1.3.6.1.4.1.2.3.51.2.22.3.2.2.2.1.1RowsmTwoPortCfgEntrynot-accessiblemandatorySwitch Module 2 port configuration information table entry
1.3.6.1.4.1.2.3.51.2.22.3.2.2.2.1.1.1ColumnsmTwoPortCfgIndexread-onlymandatorySwitch Module 2 port sequence index.
1.3.6.1.4.1.2.3.51.2.22.3.2.2.2.1.1.2ColumnsmTwoPortCfgLabelread-onlymandatorySwitch Module 2 port label
1.3.6.1.4.1.2.3.51.2.22.3.2.2.2.1.1.3ColumnsmTwoPortCfgTyperead-onlymandatorySwitch Module 2 port type: External port: This port is connected to external device and is for data traffic. External management port: This port is solely for …
1.3.6.1.4.1.2.3.51.2.22.3.2.2.2.1.1.4ColumnsmTwoPortCfgLinkSettingread-writemandatoryCurrent port link setting for Switch Module 2.
1.3.6.1.4.1.2.3.51.2.22.3.2.2.2.1.1.5ColumnsmTwoPortCfgLinkStateread-onlymandatoryCurrent port link state of Switch Module 2.
1.3.6.1.4.1.2.3.51.2.22.3.2.2.2.1.1.6ColumnsmTwoPortCfgSpeedSettingread-writemandatorySet the port speed using the data rate and duplex value. For examples: 100mf: 100Mbps in Half Duplex; 10gf: 10 Gbps in Full Duplex; auto: The working speed of …
1.3.6.1.4.1.2.3.51.2.22.3.2.2.2.1.1.7ColumnsmTwoPortCfgSpeedStatusread-onlymandatoryCurrent port speed of Switch Module 2.
1.3.6.1.4.1.2.3.51.2.22.3.2.2.2.1.1.8ColumnsmTwoPortCfgAvailSpeedsread-onlymandatoryAvailable speed setting per port for Switch Module 2. If there is more than one setting, the speeds are separated by a comma and then a space.
1.3.6.1.4.1.2.3.51.2.22.3.2.2.2.1.1.9ColumnsmTwoPortCfgMediaread-onlymandatoryPort media type of Switch Module 2.
1.3.6.1.4.1.2.3.51.2.22.3.2.2.2.1.1.10ColumnsmTwoPortCfgProtocolread-onlymandatoryPort protocol of Switch Module 2.
1.3.6.1.4.1.2.3.51.2.22.3.2.2.2.1.1.11ColumnsmTwoPortCfgWidthread-onlymandatoryThe width of the port in terms of how many combined cables are present for Switch Module 2. A value of 0 indicates this field is not applicable to the switch p…
1.3.6.1.4.1.2.3.51.2.22.3.2.2.2.1.1.12ColumnsmTwoPortCfgCableLengthread-onlymandatoryThe length (in meters) of the cable supported by this port for Switch Module 2. A value of 0 indicates this field is not applicable to the switch ports.
1.3.6.1.4.1.2.3.51.2.22.3.2.2.2.1.1.13ColumnsmTwoPortCfgCableTyperead-onlymandatoryExternal cable type for this port, for example, active copper or passive fiber.
1.3.6.1.4.1.2.3.51.2.22.3.2.2.2.1.1.14ColumnsmTwoPortCfgVendorNameread-onlymandatoryThe cable manufacturer.
1.3.6.1.4.1.2.3.51.2.22.3.2.2.2.1.1.15ColumnsmTwoPortCfgCompatibilityread-onlymandatoryCompatibility of the external cable that is plugged into the port.
1.3.6.1.4.1.2.3.51.2.22.3.2.2.2.1.1.16ColumnsmTwoPortCfgDataRateread-onlymandatoryData rate supported for this port.
1.3.6.1.4.1.2.3.51.2.22.3.2.2.3NodeswitchModThreePortCfg
1.3.6.1.4.1.2.3.51.2.22.3.2.2.3.1TablesmThreePortCfgTablenot-accessiblemandatorySwitch Module 3 port configuration information. Note: This option is not supported on all I/O modules.
1.3.6.1.4.1.2.3.51.2.22.3.2.2.3.1.1RowsmThreePortCfgEntrynot-accessiblemandatorySwitch Module 3 port configuration information table entry
1.3.6.1.4.1.2.3.51.2.22.3.2.2.3.1.1.1ColumnsmThreePortCfgIndexread-onlymandatorySwitch Module 3 port sequence index.
1.3.6.1.4.1.2.3.51.2.22.3.2.2.3.1.1.2ColumnsmThreePortCfgLabelread-onlymandatorySwitch Module 3 port label
1.3.6.1.4.1.2.3.51.2.22.3.2.2.3.1.1.3ColumnsmThreePortCfgTyperead-onlymandatorySwitch Module 3 port type: External port: This port is connected to external device and is for data traffic. External management port: This port is solely for …
1.3.6.1.4.1.2.3.51.2.22.3.2.2.3.1.1.4ColumnsmThreePortCfgLinkSettingread-writemandatoryCurrent port link setting for Switch Module 3.
1.3.6.1.4.1.2.3.51.2.22.3.2.2.3.1.1.5ColumnsmThreePortCfgLinkStateread-onlymandatoryCurrent port link state of Switch Module 3.
1.3.6.1.4.1.2.3.51.2.22.3.2.2.3.1.1.6ColumnsmThreePortCfgSpeedSettingread-writemandatorySet the port speed using the data rate and duplex value. For examples: 100mf: 100Mbps in Half Duplex; 10gf: 10 Gbps in Full Duplex; auto: The working speed of …
1.3.6.1.4.1.2.3.51.2.22.3.2.2.3.1.1.7ColumnsmThreePortCfgSpeedStatusread-onlymandatoryCurrent port speed of Switch Module 3.
1.3.6.1.4.1.2.3.51.2.22.3.2.2.3.1.1.8ColumnsmThreePortCfgAvailSpeedsread-onlymandatoryAvailable speed setting per port for Switch Module 3. If there is more than one setting, the speeds are separated by a comma and then a space.
1.3.6.1.4.1.2.3.51.2.22.3.2.2.3.1.1.9ColumnsmThreePortCfgMediaread-onlymandatoryPort media type of Switch Module 3.
1.3.6.1.4.1.2.3.51.2.22.3.2.2.3.1.1.10ColumnsmThreePortCfgProtocolread-onlymandatoryPort protocol of Switch Module 3.
1.3.6.1.4.1.2.3.51.2.22.3.2.2.3.1.1.11ColumnsmThreePortCfgWidthread-onlymandatoryThe width of the port in terms of how many combined cables are present for Switch Module 3. A value of 0 indicates this field is not applicable to the switch p…
1.3.6.1.4.1.2.3.51.2.22.3.2.2.3.1.1.12ColumnsmThreePortCfgCableLengthread-onlymandatoryThe length (in meters) of the cable supported by this port for Switch Module 3. A value of 0 indicates this field is not applicable to the switch ports.
1.3.6.1.4.1.2.3.51.2.22.3.2.2.3.1.1.13ColumnsmThreePortCfgCableTyperead-onlymandatoryExternal cable type for this port, for example, active copper or passive fiber.
1.3.6.1.4.1.2.3.51.2.22.3.2.2.3.1.1.14ColumnsmThreePortCfgVendorNameread-onlymandatoryThe cable manufacturer.
1.3.6.1.4.1.2.3.51.2.22.3.2.2.3.1.1.15ColumnsmThreePortCfgCompatibilityread-onlymandatoryCompatibility of the external cable that is plugged into the port.
1.3.6.1.4.1.2.3.51.2.22.3.2.2.3.1.1.16ColumnsmThreePortCfgDataRateread-onlymandatoryData rate supported for this port.
1.3.6.1.4.1.2.3.51.2.22.3.2.2.4NodeswitchModFourPortCfg
1.3.6.1.4.1.2.3.51.2.22.3.2.2.4.1TablesmFourPortCfgTablenot-accessiblemandatorySwitch Module 4 port configuration information. Note: This option is not supported on all I/O modules.
1.3.6.1.4.1.2.3.51.2.22.3.2.2.4.1.1RowsmFourPortCfgEntrynot-accessiblemandatorySwitch Module 4 port configuration information table entry
1.3.6.1.4.1.2.3.51.2.22.3.2.2.4.1.1.1ColumnsmFourPortCfgIndexread-onlymandatorySwitch Module 4 port sequence index.
1.3.6.1.4.1.2.3.51.2.22.3.2.2.4.1.1.2ColumnsmFourPortCfgLabelread-onlymandatorySwitch Module 4 port label
1.3.6.1.4.1.2.3.51.2.22.3.2.2.4.1.1.3ColumnsmFourPortCfgTyperead-onlymandatorySwitch Module 4 port type: External port: This port is connected to external device and is for data traffic. External management port: This port is solely for …
1.3.6.1.4.1.2.3.51.2.22.3.2.2.4.1.1.4ColumnsmFourPortCfgLinkSettingread-writemandatoryCurrent port link setting for Switch Module 4.
1.3.6.1.4.1.2.3.51.2.22.3.2.2.4.1.1.5ColumnsmFourPortCfgLinkStateread-onlymandatoryCurrent port link state of Switch Module 4.
1.3.6.1.4.1.2.3.51.2.22.3.2.2.4.1.1.6ColumnsmFourPortCfgSpeedSettingread-writemandatorySet the port speed using the data rate and duplex value. For examples: 100mf: 100Mbps in Half Duplex; 10gf: 10 Gbps in Full Duplex; auto: The working speed of …
1.3.6.1.4.1.2.3.51.2.22.3.2.2.4.1.1.7ColumnsmFourPortCfgSpeedStatusread-onlymandatoryCurrent port speed of Switch Module 4.
1.3.6.1.4.1.2.3.51.2.22.3.2.2.4.1.1.8ColumnsmFourPortCfgAvailSpeedsread-onlymandatoryAvailable speed setting per port for Switch Module 4. If there is more than one setting, the speeds are separated by a comma and then a space.
1.3.6.1.4.1.2.3.51.2.22.3.2.2.4.1.1.9ColumnsmFourPortCfgMediaread-onlymandatoryPort media type of Switch Module 4.
1.3.6.1.4.1.2.3.51.2.22.3.2.2.4.1.1.10ColumnsmFourPortCfgProtocolread-onlymandatoryPort protocol of Switch Module 4.
1.3.6.1.4.1.2.3.51.2.22.3.2.2.4.1.1.11ColumnsmFourPortCfgWidthread-onlymandatoryThe width of the port in terms of how many combined cables are present for Switch Module 4. A value of 0 indicates this field is not applicable to the switch p…
1.3.6.1.4.1.2.3.51.2.22.3.2.2.4.1.1.12ColumnsmFourPortCfgCableLengthread-onlymandatoryThe length (in meters) of the cable supported by this port for Switch Module 4. A value of 0 indicates this field is not applicable to the switch ports.
1.3.6.1.4.1.2.3.51.2.22.3.2.2.4.1.1.13ColumnsmFourPortCfgCableTyperead-onlymandatoryExternal cable type for this port, for example, active copper or passive fiber.
1.3.6.1.4.1.2.3.51.2.22.3.2.2.4.1.1.14ColumnsmFourPortCfgVendorNameread-onlymandatoryThe cable manufacturer.
1.3.6.1.4.1.2.3.51.2.22.3.2.2.4.1.1.15ColumnsmFourPortCfgCompatibilityread-onlymandatoryCompatibility of the external cable that is plugged into the port.
1.3.6.1.4.1.2.3.51.2.22.3.2.2.4.1.1.16ColumnsmFourPortCfgDataRateread-onlymandatoryData rate supported for this port.
1.3.6.1.4.1.2.3.51.2.22.4NodechassisTopology
1.3.6.1.4.1.2.3.51.2.22.4.1ScalarchassisResponseVersionread-onlymandatoryChassis response version.
1.3.6.1.4.1.2.3.51.2.22.4.2ScalarchassisFlagsread-onlymandatoryChassis flags. 1 = a server blade chassis, 0 = a rack or standalone chassis.
1.3.6.1.4.1.2.3.51.2.22.4.18ScalarchassisNoOfFPsSupportedread-onlydeprecatedThis object is deprecated because the power modules' fan packs are integrated into the power modules and are not removable as on previous power modules. Number…
1.3.6.1.4.1.2.3.51.2.22.4.19ScalarchassisNoOfBayDevicesSupportedread-onlymandatoryMaximum number of bays found in the chassis.
1.3.6.1.4.1.2.3.51.2.22.4.20ScalarchassisNoOfSMsSupportedread-onlymandatoryNumber of switch modules (SMs) supported.
1.3.6.1.4.1.2.3.51.2.22.4.21ScalarchassisNoOfMMsSupportedread-onlymandatoryNumber of management modules (MMs) supported.
1.3.6.1.4.1.2.3.51.2.22.4.22ScalarchassisNoOfPMsSupportedread-onlymandatoryNumber of power modules (PMs) supported.
1.3.6.1.4.1.2.3.51.2.22.4.23ScalarchassisNoOfRearLEDCardsSupportedread-onlymandatoryNumber of rear LED cards supported.
1.3.6.1.4.1.2.3.51.2.22.4.24ScalarchassisNoOfChassisFansSupportedread-onlymandatoryNumber of chassis fans supported.
1.3.6.1.4.1.2.3.51.2.22.4.25ScalarchassisBayDevicesInstalledread-onlymandatoryThe bay devices that are installed in the chassis. The bay devices are listed as a bitmap. The bitmap is a string containing a list of 1's and 0's that is as l…
1.3.6.1.4.1.2.3.51.2.22.4.29ScalarchassisSMsInstalledread-onlymandatoryThe switch modules that are installed on the chassis. The switch modules are listed as a bitmap. The bitmap is a string containing a list of 1's and 0's that i…
1.3.6.1.4.1.2.3.51.2.22.4.30ScalarchassisMMsInstalledread-onlymandatoryThe management modules that are installed on the chassis. The management modules are listed as a bitmap. The bitmap is a string containing a list of 1's and 0'…
1.3.6.1.4.1.2.3.51.2.22.4.31ScalarchassisPMsInstalledread-onlymandatoryThe power modules that are installed on the chassis. The power modules are listed as a bitmap. The bitmap is a string containing a list of 1's and 0's that is …
1.3.6.1.4.1.2.3.51.2.22.4.32ScalarchassisRearLEDCardInstalledread-onlymandatoryIndicates whether at least one rear LED card is installed.
1.3.6.1.4.1.2.3.51.2.22.4.33ScalarchassisFansInstalledread-onlymandatoryThe chassis fans that are installed on the chassis. They are listed as a bitmap. The bitmap is a string containing a list of 1's and 0's that is as long as the…
1.3.6.1.4.1.2.3.51.2.22.4.34ScalarchassisActiveMMread-onlymandatoryThe active management module (MM).
1.3.6.1.4.1.2.3.51.2.22.4.37ScalarchassisFPsInstalledread-onlydeprecatedThis object is deprecated because the power modules' fan packs are integrated into the power modules and are not removable as on previous power modules. The fa…
1.3.6.1.4.1.2.3.51.2.22.4.38ScalarchassisTyperead-onlymandatoryThe type of the chassis. This MIB object should be used in conjunction with chassisSubType MIB object to determine the characteristic of the chassis.
1.3.6.1.4.1.2.3.51.2.22.4.39ScalarchassisSubtyperead-onlymandatoryThe subtype of the chassis. This MIB object should be used in conjunction with chassisType MIB object to determine the characteristic of the chassis.
1.3.6.1.4.1.2.3.51.2.22.4.52ScalarchassisNoOfRearLEDCardsInstalledread-onlymandatoryThe rear LED cards that are installed on the chassis.
1.3.6.1.4.1.2.3.51.2.22.4.53ScalarchassisRoomread-writemandatoryThe name of the room where the chassis is located. Maximum 23 characters for name plus NULL termination.
1.3.6.1.4.1.2.3.51.2.22.4.54ScalarchassisNameread-writemandatoryThe name of the chassis. Maximum 15 character long plus NULL termination.
1.3.6.1.4.1.2.3.51.2.22.4.55ScalarchassisRackread-writemandatoryThe name of the room where the chassis is located. Maximum 23 characters for name plus NULL termination.
1.3.6.1.4.1.2.3.51.2.22.4.56ScalarchassisLowestUread-writemandatoryThe lowest U position that is occupied in the rack.
1.3.6.1.4.1.2.3.51.2.22.4.57ScalarchassisUHeightread-onlymandatoryThe height of the chassis in 'U' units.
1.3.6.1.4.1.2.3.51.2.22.5NodemanagementModule
1.3.6.1.4.1.2.3.51.2.22.5.1TablemmStatusTablenot-accessiblemandatoryTable of the management module status.
1.3.6.1.4.1.2.3.51.2.22.5.1.1RowmmStatusEntrynot-accessiblemandatoryManagement module status entry.
1.3.6.1.4.1.2.3.51.2.22.5.1.1.1ColumnmmStatusIndexread-onlymandatoryManagement module status index.
1.3.6.1.4.1.2.3.51.2.22.5.1.1.2ColumnmmPresentread-onlymandatoryManagement module current status.
1.3.6.1.4.1.2.3.51.2.22.5.1.1.3ColumnmmExtIpAddressread-onlymandatoryManagement module external IP address. NOTE: The IPv6 addresses assigned to the MM may be viewed with the extEthernetInterfaceIPv6 objects
1.3.6.1.4.1.2.3.51.2.22.5.1.1.4ColumnmmPrimaryread-onlymandatoryIndicates if this Management module is a primary or not. NOTE: If there is no standby MM, this value defaults to primary.
1.3.6.1.4.1.2.3.51.2.22.5.1.1.5ColumnmmHealthStateread-onlymandatoryThe health state for the management module. 0 = unknown, 1 = good, 2 = warning, 3 = bad.
1.3.6.1.4.1.2.3.51.2.22.8NodefirmwareInformation
1.3.6.1.4.1.2.3.51.2.22.8.1NodesmFirmwareInformation
1.3.6.1.4.1.2.3.51.2.22.8.1.1TablesmFirmwareInfoTablenot-accessiblemandatorySwitch Module firmware image information.
1.3.6.1.4.1.2.3.51.2.22.8.1.1.1RowsmFirmwareInfoEntrynot-accessiblemandatorySwitch Module firmware image information table entry
1.3.6.1.4.1.2.3.51.2.22.8.1.1.1.1ColumnsmFirmwareInfoIndexread-onlymandatorySequence index in the firmware table.
1.3.6.1.4.1.2.3.51.2.22.8.1.1.1.2ColumnsmFirmwareInfoModIndexread-onlymandatorySwitch Module number.
1.3.6.1.4.1.2.3.51.2.22.8.1.1.1.3ColumnsmFirmwareInfoImageIndexread-onlymandatorySwitch Module firmware image index.
1.3.6.1.4.1.2.3.51.2.22.8.1.1.1.4ColumnsmFirmwareInfoImageNameread-writemandatorySwitch Module firmware image name
1.3.6.1.4.1.2.3.51.2.22.9NodefirmwareUpdate
1.3.6.1.4.1.2.3.51.2.22.9.1ScalarfirmwareUpdateTargetread-writemandatoryTarget module whose firmware will be updated. NOTE: Some switch modules do not allow firmware update. When firmware update is attempted on those switch modules…
1.3.6.1.4.1.2.3.51.2.22.9.2ScalarfirmwareUpdateTftpServerread-writemandatoryIf flashing via the legacy method using a tftp server, then set the IP address or host name of the TFTP server where the firmware file resides. The address mus…
1.3.6.1.4.1.2.3.51.2.22.9.3ScalarfirmwareUpdateFileNameread-writemandatoryFile name of the firmware file.
1.3.6.1.4.1.2.3.51.2.22.9.4ScalarfirmwareUpdateStartread-writemandatoryStart updating the firmware of the specified target module. Using execute or execute-with-reboot will cause the SNMP client to wait for the firmware update to …
1.3.6.1.4.1.2.3.51.2.22.9.5ScalarfirmwareUpdateStatusread-onlymandatoryGet the status of the last firmware update which was initiated through SNMP method.
1.3.6.1.4.1.2.3.51.2.22.9.6ScalarstandbyFirmwareUpdateStatusread-onlymandatoryGet the current status of the firmware update for the standby MM. NOTE: This only applies to systems with a standby MM.
1.3.6.1.4.1.2.3.51.2.22.9.7ScalarfirmwareImageNumberread-writemandatoryIf the module can upload more than one image, an image number must be specified after setting the firmware target. Please refer to the firmwareInformation sect…
1.3.6.1.4.1.2.3.51.2.22.9.8ScalarfirmwareActiveImageread-writemandatoryIf the module can upload more than one image, an active image number must be specified. Please refer to the firmwareInformation section. NOTE: Value returned f…
1.3.6.1.4.1.2.3.51.2.22.9.9ScalarfirmwareUpdateServerread-writemandatoryContains the fully qualified remote location of the firmware packet file. Use firmwareUpdateFileName to specify the filename. A fully qualified remote location…
1.3.6.1.4.1.2.3.51.2.22.11NodefileManagement
1.3.6.1.4.1.2.3.51.2.22.11.1NodefileTopology
1.3.6.1.4.1.2.3.51.2.22.11.1.1ScalarcurrentDirectoryread-writemandatorySpecifies the directory name for listing the requested files.
1.3.6.1.4.1.2.3.51.2.22.11.1.2TablefileDetailsTablenot-accessiblemandatoryA table of all the files in the specified directory.
1.3.6.1.4.1.2.3.51.2.22.11.1.2.1RowfileDetailsEntrynot-accessiblemandatoryFile details entry.
1.3.6.1.4.1.2.3.51.2.22.11.1.2.1.1ColumnfileIndexread-onlymandatoryFile sequence index.
1.3.6.1.4.1.2.3.51.2.22.11.1.2.1.2ColumnfileNameread-onlymandatoryFile name.
1.3.6.1.4.1.2.3.51.2.22.11.1.2.1.3ColumnfileLastUpdateread-onlymandatoryDate of the latest file update.
1.3.6.1.4.1.2.3.51.2.22.11.1.2.1.4ColumnfileSizeread-onlymandatoryFile size in bytes.
1.3.6.1.4.1.2.3.51.2.22.11.3ScalarfileManagementCmdread-writemandatoryThis field will execute the selected operations on the files. The following operation is supported: DEL name - delete a file Examples: - to delete the file nam…
1.3.6.1.4.1.2.3.51.2.22.11.6ScalarfileSystemSpaceAvailableread-onlymandatoryThis field displays the available space of the MM file system.
1.3.6.1.4.1.2.3.51.2.22.12NodecmeRemoteChassis
1.3.6.1.4.1.2.3.51.2.22.12.1TablecmeRemoteChassisTablenot-accessiblemandatoryThis table is used to provide the discovered MMs based on the new, extended SLP response information.
1.3.6.1.4.1.2.3.51.2.22.12.1.1RowcmeRemoteChassisEntrynot-accessiblemandatoryRemote chassis entry
1.3.6.1.4.1.2.3.51.2.22.12.1.1.1ColumncmeRemoteChassisIndexread-onlymandatoryRemote chassis discovery sequence index.
1.3.6.1.4.1.2.3.51.2.22.12.1.1.2ColumncmeSystemNameread-onlymandatorySystem name for this discovery management module.
1.3.6.1.4.1.2.3.51.2.22.12.1.1.3ColumncmeTyperead-onlymandatoryManagement module service processor type.
1.3.6.1.4.1.2.3.51.2.22.12.1.1.4ColumncmeSerialread-onlymandatoryManagement module serial number.
1.3.6.1.4.1.2.3.51.2.22.12.1.1.5ColumncmeFruread-onlymandatoryManagement module Field-Replaceable number.
1.3.6.1.4.1.2.3.51.2.22.12.1.1.6ColumncmeUuidread-onlymandatoryManagement module UUID.
1.3.6.1.4.1.2.3.51.2.22.12.1.1.7ColumncmeSlotread-onlymandatoryManagement module slot.
1.3.6.1.4.1.2.3.51.2.22.12.1.1.8ColumncmeMidPidread-onlymandatoryManagement module Mid-plane Pid.
1.3.6.1.4.1.2.3.51.2.22.12.1.1.9ColumncmeMacAddressread-onlymandatoryManagement module MAC address.
1.3.6.1.4.1.2.3.51.2.22.12.1.1.10ColumncmeChassisSerialread-onlymandatoryChassis serial number.
1.3.6.1.4.1.2.3.51.2.22.12.1.1.11ColumncmeChassisFruread-onlymandatoryChassis Field-Replaceable number.
1.3.6.1.4.1.2.3.51.2.22.12.1.1.12ColumncmeChassisMachineTypeModeread-onlymandatoryChassis machine type and model number.
1.3.6.1.4.1.2.3.51.2.22.12.1.1.13ColumncmeSystemStatusread-onlymandatoryChassis status.
1.3.6.1.4.1.2.3.51.2.22.12.1.1.14ColumncmeChassisUuidread-onlymandatoryChassis UUID.
1.3.6.1.4.1.2.3.51.2.22.12.1.1.15ColumncmeChassisMidPidread-onlymandatoryChassis mid-plane ID.
1.3.6.1.4.1.2.3.51.2.22.12.1.1.16ColumncmeChassisIdread-onlymandatoryChassis ID.
1.3.6.1.4.1.2.3.51.2.22.12.1.1.17ColumncmeChassisLocationread-onlymandatoryChassis location information.
1.3.6.1.4.1.2.3.51.2.22.12.1.1.18ColumncmeChassisRoomIdread-onlymandatoryChassis room ID.
1.3.6.1.4.1.2.3.51.2.22.12.1.1.19ColumncmeChassisRackIdread-onlymandatoryChassis rack ID.
1.3.6.1.4.1.2.3.51.2.22.12.1.1.20ColumncmeChassisUserread-onlymandatoryChassis user information.
1.3.6.1.4.1.2.3.51.2.22.12.1.1.21ColumncmeChassisFruListread-onlymandatoryChassis FRU list.
1.3.6.1.4.1.2.3.51.2.22.12.1.1.22ColumncmeFirmwareVersionread-onlymandatoryFirmware version of the discovery management module.
1.3.6.1.4.1.2.3.51.2.22.12.1.1.23ColumncmeChassisTyperead-onlymandatoryChassis type.
1.3.6.1.4.1.2.3.51.2.22.12.1.1.24ColumncmeIpv4Statusread-onlymandatoryA flag to state if IPv4 is enabled
1.3.6.1.4.1.2.3.51.2.22.12.1.1.25ColumncmeIpv4Addressesread-onlymandatoryThe IPv4 addresses configured for the chassis.
1.3.6.1.4.1.2.3.51.2.22.12.1.1.26ColumncmeIpv4AddressesFloatread-onlymandatoryThe floating IPv4 addresses configured for the chassis.
1.3.6.1.4.1.2.3.51.2.22.12.1.1.27ColumncmeIpv4Protocolsread-onlymandatoryThe IPv4 protocols configured for the chassis.
1.3.6.1.4.1.2.3.51.2.22.12.1.1.28ColumncmeIpv6Statusread-onlymandatoryA flag to state if IPv6 is enabled
1.3.6.1.4.1.2.3.51.2.22.12.1.1.29ColumncmeIpv6Addressesread-onlymandatoryThe IPv6 addresses configured for the chassis.
1.3.6.1.4.1.2.3.51.2.22.12.1.1.30ColumncmeIpv6AddressesFloatread-onlymandatoryThe floating IPv6 addresses configured for the chassis.
1.3.6.1.4.1.2.3.51.2.22.12.1.1.31ColumncmeIpv6Protocolsread-onlymandatoryThe IPv6 protocols configured for the chassis.
1.3.6.1.4.1.2.3.51.2.22.12.2ScalarchassisDiscoveryread-writemandatoryDiscovery of remote Chassis. NOTE: Value returned for the GET command is meaningless for this MIB object.
1.3.6.1.4.1.2.3.51.2.22.31NodecomponentPower
1.3.6.1.4.1.2.3.51.2.22.31.1TablecomponentPowerTablenot-accessiblemandatoryTable of component remote power control information. Contains power on/off enablement status for each component.
1.3.6.1.4.1.2.3.51.2.22.31.1.1RowcomponentPowerEntrynot-accessiblemandatoryComponent power/restart table entry
1.3.6.1.4.1.2.3.51.2.22.31.1.1.1ColumncomponentPowerTopologyPathread-onlymandatoryThe unique identifier for a component in this table. The chassis and each installed component is represented by a hardware topology tree, where each node in th…
1.3.6.1.4.1.2.3.51.2.22.31.1.1.2ColumncomponentPowerNameread-onlymandatoryThe name of the component as a null terminated string.
1.3.6.1.4.1.2.3.51.2.22.31.1.1.3ColumncomponentPowerStateread-onlymandatoryIndicates the power state of the component specified. If the state cannot be determined, the unknown(255) is returned.
1.3.6.1.4.1.2.3.51.2.22.31.1.1.4ColumncomponentPowerActionread-writemandatoryControl the power state of a specific component. none: No action, value returned for GET. off: Power-off component. on: Power-on component. softoff: Shutdown O…
1.3.6.1.4.1.2.3.51.2.22.31.1.1.5ColumncomponentPowerEnableSMSBootMenuread-writemandatoryEnables/disables a component restart to the SMS boot menu. Setting this object to 'enable(1)' will cause a reboot of the node to the SMS menu. This option is n…
1.3.6.1.4.1.2.3.51.2.22.31.2ScalarcomponentPowerTableCacheTimeoutread-onlymandatoryThe timeout value (in seconds) of the cached data for the table, componentPowerTable. This value is static (constant) and cannot be set.
1.3.6.1.4.1.2.3.51.2.22.31.6TablecomponentPowerDetailsTablenot-accessiblemandatoryTable of component power detail information.
1.3.6.1.4.1.2.3.51.2.22.31.6.1RowcomponentPowerDetailsEntrynot-accessiblemandatoryComponent power Details table entry
1.3.6.1.4.1.2.3.51.2.22.31.6.1.1ColumncomponentPowerDetailsTopologyPathread-onlymandatoryThe unique identifier for a component in this table. The chassis and each installed component is represented by a hardware topology tree, where each node in th…
1.3.6.1.4.1.2.3.51.2.22.31.6.1.2ColumncomponentPowerDetailsNameread-onlymandatoryThe name of the component as a null terminated string.
1.3.6.1.4.1.2.3.51.2.22.31.6.1.3ColumncomponentPowerDetailsMaxPowerConfigread-writemandatoryComponent Module Details Table Maximum Power Configuration. Allow the user to set the maximum power that can be used by the component. This function is also kn…
1.3.6.1.4.1.2.3.51.2.22.31.6.1.4ColumncomponentPowerDetailsEffectiveClockRateread-onlymandatoryComponent Module Details Table Effective CPU Clock Rate applies to DPM components only. It displays processor's effective clock rate based on sample interval. …
1.3.6.1.4.1.2.3.51.2.22.31.6.1.5ColumncomponentPowerDetailsMaximumClockRateread-onlymandatoryComponent Module Details Table Maximum CPU Clock Rate applies to DPM components only. It displays processor's maximum clock rate based on sample interval. Note…
1.3.6.1.4.1.2.3.51.2.22.31.6.1.6ColumncomponentPowerDetailsPowerSaverModeread-writemandatoryWhen enabled, the static low power saver mode allows the component to selectively alter its operating voltage and frequency to reduce power consumption. This f…
1.3.6.1.4.1.2.3.51.2.22.31.6.1.7ColumncomponentPowerDetailsDynamicPowerSaverread-writemandatoryWhen enabled, Dynamic Power Saver allows the voltage and frequency of the CPUs on the component to be controlled based on how busy the CPU is. This feature is …
1.3.6.1.4.1.2.3.51.2.22.31.6.1.8ColumncomponentPowerDetailsDynamicPowerFavorPerformanceOverPowerread-writemandatoryWhen enabled, Dynamic Power Favor Performance Over Power supports a max performance mode that pushes the system past its nominal CPU frequency when CPU and mem…
1.3.6.1.4.1.2.3.51.2.22.31.6.1.9ColumncomponentPowerDetailsPowerControlread-writemandatoryThis object is used to get or set the power control setting on a component. If dynamic power mgmt is not supported on a component, notApplicable(255) will be r…
1.3.6.1.4.1.2.3.51.2.22.31.6.1.10ColumncomponentPowerDetailsPcapMinread-onlymandatoryComponent Module Details Table power capping Minimum value in watts. The component must support the advanced power management feature. If the value of Pcap Min…
1.3.6.1.4.1.2.3.51.2.22.31.6.1.11ColumncomponentPowerDetailsPcapGuaranteedMinread-onlymandatoryComponent Module Details Table power capping Guaranteed Minimum value in watts. The component must support the advanced power management feature. If the value …
1.3.6.1.4.1.2.3.51.2.22.31.6.1.12ColumncomponentPowerDetailsPcapMaxread-onlymandatoryComponent Module Details Table power capping Maximum value in watts. The component must support the advanced power management feature. If the value is '<max1> …
1.3.6.1.4.1.2.3.51.2.22.31.6.1.13ColumncomponentPowerDetailsStaticCapread-onlymandatoryComponent Module Details Table static capabilities list. This is a list of five power management capabilities that the component may or may not support. The li…
1.3.6.1.4.1.2.3.51.2.22.31.6.1.14ColumncomponentPowerDetailsRuntimeCapread-onlymandatoryComponent Module Details Table run-time capabilities list. If the component supports the capability as indicated in the static capability information, the user…
1.3.6.1.4.1.2.3.51.2.22.31.7ScalarcomponentPowerDetailsTableCacheTimeoutread-onlymandatoryThe timeout value (in seconds) of the cached data for the table, componentPowerDetailsTable. This value is static (constant) and cannot be set.
1.3.6.1.4.1.2.3.51.2.22.32NodecomponentConfiguration
1.3.6.1.4.1.2.3.51.2.22.32.1TablecomponentBayDataTablenot-accessiblemandatoryTable of component bay User data information. Contains user provided data for each component bay.
1.3.6.1.4.1.2.3.51.2.22.32.1.1RowcomponentBayDataEntrynot-accessiblemandatoryComponent Bay Data table entry
1.3.6.1.4.1.2.3.51.2.22.32.1.1.1ColumncomponentBayDataTopologyPathread-onlymandatoryThe unique identifier for a component in this table. The chassis and each installed component is represented by a hardware topology tree, where each node in th…
1.3.6.1.4.1.2.3.51.2.22.32.1.1.2ColumncomponentBayDataNameread-onlymandatoryThe name of the component as a null terminated string.
1.3.6.1.4.1.2.3.51.2.22.32.1.1.3ColumncomponentBayDataStatusread-onlymandatoryThis shows Bay Data (BD) Status. 0 means the component fully supports BD. 1 means that the component's BIOS does not support BD. 2 means that there is no compo…
1.3.6.1.4.1.2.3.51.2.22.32.1.1.4ColumncomponentBayDataread-writemandatoryA null terminated string that defines the component Bay Data. This data is puched to the components's BSMP and SMBIOS structures, where it can be used by the c…
1.3.6.1.4.1.2.3.51.2.22.32.2ScalarcomponentBayDataTableCacheTimeoutread-onlymandatoryThe timeout value (in seconds) of the cached data for the table, componentBayDataTable. This value is static (constant) and cannot be set.
1.3.6.1.4.1.2.3.51.2.22.32.6TablecomponentEthOverUSBInterfaceTablenot-accessiblemandatoryTable of blade Service Processor's Ethernet over USB interface.
1.3.6.1.4.1.2.3.51.2.22.32.6.1RowcomponentEthOverUSBInterfaceEntrynot-accessiblemandatoryBlade Service Processor's Ethernet over USB interface entry.
1.3.6.1.4.1.2.3.51.2.22.32.6.1.1ColumncomponentEthOverUSBInterfaceTopologyPathread-onlymandatoryThe unique identifier for a component in this table. The chassis and each installed component is represented by a hardware topology tree, where each node in th…
1.3.6.1.4.1.2.3.51.2.22.32.6.1.2ColumncomponentEthOverUSBInterfaceNameread-onlymandatoryThe name of the component as a null terminated string.
1.3.6.1.4.1.2.3.51.2.22.32.6.1.3ColumncomponentEthOverUSBInterfaceEnableread-writemandatoryThis object allows the user to view the status of, and enable or disable, a component's interface on Ethernet-over-USB. NOTE: If the component either does not …
1.3.6.1.4.1.2.3.51.2.22.32.7ScalarcomponentEthOverUSBInterfaceTableCacheTimeoutread-onlymandatoryThe timeout value (in seconds) of the cached data for the table, componentEthOverUSBInterfaceTable. This value is static (constant) and cannot be set.
1.3.6.1.4.1.2.3.51.2.22.32.11TablecomponentConfigurationTablenot-accessiblemandatoryTable of component configuration information.
1.3.6.1.4.1.2.3.51.2.22.32.11.1RowcomponentConfigurationEntrynot-accessiblemandatoryComponent configuration table entry
1.3.6.1.4.1.2.3.51.2.22.32.11.1.1ColumncomponentConfigurationTopologyPathread-onlymandatoryThe unique identifier for a component in this table. The chassis and each installed component is represented by a hardware topology tree, where each node in th…
1.3.6.1.4.1.2.3.51.2.22.32.11.1.2ColumncomponentConfigurationNameread-writemandatoryThe name of the component as a null terminated string. This object is configurable.
1.3.6.1.4.1.2.3.51.2.22.32.11.1.3ColumncomponentConfigurationActiveBootModeread-onlymandatoryIndicates the active copy of the firmware from which the component is booting. NOTE: Some components do not support the automatic boot recovery. It displays 'n…
1.3.6.1.4.1.2.3.51.2.22.32.11.1.4ColumncomponentConfigurationPendingBootModeread-writemandatoryIndicates the copy of the firmware from which the component will boot after the next reboot. NOTE: Some components do not support the automatic boot recovery. …
1.3.6.1.4.1.2.3.51.2.22.32.11.1.5ColumncomponentConfigurationAutoPowerOnread-writemandatoryComponent auto-power on policy. - restore: component will be powered on which were previously on. - auto: component will automatically be powered on when power…
1.3.6.1.4.1.2.3.51.2.22.32.11.1.6ColumncomponentConfigurationPowerOnRestartDelayread-writemandatoryRestart delay (in seconds) when power is applied to a component.
1.3.6.1.4.1.2.3.51.2.22.32.11.1.7ColumncomponentConfigurationLocalPowerControlEnableread-writemandatoryComponent local power control enablement status.
1.3.6.1.4.1.2.3.51.2.22.32.11.1.8ColumncomponentConfigurationWakeOnLanControlEnableread-writemandatoryComponent Wake On LAN enablement status. If WOL is not supported by the component, it displays 'notApplicable' and WOL can not be enabled or disabled.
1.3.6.1.4.1.2.3.51.2.22.32.12ScalarcomponentConfigurationTableCacheTimeoutread-onlymandatoryThe timeout value (in seconds) of the cached data for the table, componentConfigurationTable. This value is static (constant) and cannot be set.
1.3.6.1.4.1.2.3.51.2.22.32.16NodecomponentNetworkConfiguration
1.3.6.1.4.1.2.3.51.2.22.32.16.1TablecomponentIPv4ConfigTablenot-accessiblemandatoryTable of all components' network interfaces.
1.3.6.1.4.1.2.3.51.2.22.32.16.1.1RowcomponentIPv4ConfigEntrynot-accessiblemandatoryComponent configuration table entry
1.3.6.1.4.1.2.3.51.2.22.32.16.1.1.1ColumncomponentIPv4ConfigTopologyPathread-onlymandatoryThe unique identifier for a component in this table. The chassis and each installed component is represented by a hardware topology tree, where each node in th…
1.3.6.1.4.1.2.3.51.2.22.32.16.1.1.2ColumncomponentIPv4ConfigPortIndexread-onlymandatoryThe physical port number of the given entry.
1.3.6.1.4.1.2.3.51.2.22.32.16.1.1.3ColumncomponentIPv4ConfigNameread-onlymandatoryThe name of the component as a null terminated string.
1.3.6.1.4.1.2.3.51.2.22.32.16.1.1.4ColumncomponentIPv4ConfigPortLabelread-onlymandatoryShow string label that identifies the interface.
1.3.6.1.4.1.2.3.51.2.22.32.16.1.1.5ColumncomponentIPv4ConfigPhysicalLinkStatusread-onlymandatoryIndicates whether this network interface port is up or down. If this network interface doesn't support up/down, show 'notApplicable(255)'.
1.3.6.1.4.1.2.3.51.2.22.32.16.1.1.6ColumncomponentIPv4ConfigPhysicalLinkStateread-writemandatoryConfiguration object for requesting the physical port to be either, down(0), up(1) or loopback(2). To get the current status of a physical port, use the object…
1.3.6.1.4.1.2.3.51.2.22.32.16.1.1.7ColumncomponentIPv4ConfigIPAddrread-writemandatoryShow/modify current IP address of the component network interface. Note that only if the componentIPv4ConfigPhysicalLinkStatus is 'up(1)' and the componentIPv4…
1.3.6.1.4.1.2.3.51.2.22.32.16.1.1.8ColumncomponentIPv4ConfigSubnetMaskread-writemandatoryShow or modifie current subnet mask of the component network interface. Note that only if the componentIPv4ConfigPhysicalLinkStatus is 'up(1)' and the componen…
1.3.6.1.4.1.2.3.51.2.22.32.16.1.1.9ColumncomponentIPv4ConfigGatewayAddrread-writemandatoryShow or modify current IP gateway of the component network interface. Note that only if the componentIPv4ConfigPhysicalLinkStatus is 'up(1)' and the componentI…
1.3.6.1.4.1.2.3.51.2.22.32.16.1.1.10ColumncomponentIPv4ConfigVlanIdread-writemandatoryThis is the Virtual LAN ID for supported network interface cards (NICs). The range of valid VLAN ID's is 0 to 4095.
1.3.6.1.4.1.2.3.51.2.22.32.16.1.1.11ColumncomponentIPv4ConfigDHCPEnableread-writemandatoryIP config method on the component network interface to modify mode to static IP, DHCP and 'try DHCP then try static'. If this network interface doesn't support…
1.3.6.1.4.1.2.3.51.2.22.32.16.1.1.12ColumncomponentIPv4ConfigMACAddrread-onlymandatoryShow the component network interface MAC address. If this network interface doesn't support MAC, show 'notApplicable'.
1.3.6.1.4.1.2.3.51.2.22.32.16.2ScalarcomponentIPv4ConfigTableCacheTimeoutread-onlymandatoryThe timeout value (in seconds) of the cached data for the table, componentIPv4ConfigTable. This value is static (constant) and cannot be set.
1.3.6.1.4.1.2.3.51.2.22.32.16.11NodecomponentIPv6Config
1.3.6.1.4.1.2.3.51.2.22.32.16.11.1TablecomponentIPv6ConfigTablenot-accessiblemandatoryA table of IPv6 configuration options for components. NOTE: This MIB object is not applicable to components that do not support IPv6.
1.3.6.1.4.1.2.3.51.2.22.32.16.11.1.1RowcomponentIPv6ConfigEntrynot-accessiblemandatoryIPv6 configuration options for a component. NOTE: This MIB object is not applicable to components that do not support IPv6.
1.3.6.1.4.1.2.3.51.2.22.32.16.11.1.1.1ColumncomponentIPv6ConfigTopologyPathread-onlymandatoryThe unique identifier for a component in this table. The chassis and each installed component is represented by a hardware topology tree, where each node in th…
1.3.6.1.4.1.2.3.51.2.22.32.16.11.1.1.2ColumncomponentIPv6ConfigPortIndexread-onlymandatoryThe physical port number of the given entry
1.3.6.1.4.1.2.3.51.2.22.32.16.11.1.1.3ColumncomponentIPv6ConfigNameread-onlymandatoryThe name of the component as a null terminated string.
1.3.6.1.4.1.2.3.51.2.22.32.16.11.1.1.4ColumncomponentIPv6ConfigEnabledread-writemandatoryEnables/Disables IPv6 support on the component.
1.3.6.1.4.1.2.3.51.2.22.32.16.11.1.1.5ColumncomponentIPv6ConfigStaticread-writemandatoryEnables/Disables IPv6 static configuration support on the component.
1.3.6.1.4.1.2.3.51.2.22.32.16.11.1.1.6ColumncomponentDHCPv6ConfigEnabledread-writemandatoryEnables/Disables DHCPv6 address configuration support on the component.
1.3.6.1.4.1.2.3.51.2.22.32.16.11.1.1.7ColumncomponentIPv6ConfigStatelessEnabledread-writemandatoryEnables/Disables IPv6 stateless auto-configuration support on the component.
1.3.6.1.4.1.2.3.51.2.22.32.16.11.2ScalarcomponentIPv6ConfigTableCacheTimeoutread-onlymandatoryThe timeout value (in seconds) of the cached data for the table, componentIPv6ConfigTable. This value is static (constant) and cannot be set.
1.3.6.1.4.1.2.3.51.2.22.32.16.11.6TablecomponentIPv6AddressTablenot-accessiblemandatoryA table of assigned IPv6 addresses for components. NOTE: This MIB object is not applicable to components that do not support IPv6.
1.3.6.1.4.1.2.3.51.2.22.32.16.11.6.1RowcomponentIPv6AddressEntrynot-accessiblemandatoryThe assigned IPv6 address for a given component. NOTE: This MIB object is not applicable to components that do not support IPv6.
1.3.6.1.4.1.2.3.51.2.22.32.16.11.6.1.1ColumncomponentIPv6AddressTopologyPathread-onlymandatoryThe unique identifier for a component in this table. The chassis and each installed component is represented by a hardware topology tree, where each node in th…
1.3.6.1.4.1.2.3.51.2.22.32.16.11.6.1.2ColumncomponentIPv6AddressPortIndexread-onlymandatoryThe component's physical port number for the given entry.
1.3.6.1.4.1.2.3.51.2.22.32.16.11.6.1.3ColumncomponentIPv6AddressEntryIndexread-onlymandatoryThe component's address entry index.
1.3.6.1.4.1.2.3.51.2.22.32.16.11.6.1.4ColumncomponentIPv6AddressNameread-onlymandatoryThe name of the component as a null terminated string.
1.3.6.1.4.1.2.3.51.2.22.32.16.11.6.1.5ColumncomponentIPv6AddressTyperead-onlymandatoryThe address type.
1.3.6.1.4.1.2.3.51.2.22.32.16.11.6.1.6ColumncomponentIPv6Addressread-writemandatoryThe assigned IPv6 address. Note: 'write' is for static ipv6 only.
1.3.6.1.4.1.2.3.51.2.22.32.16.11.6.1.7ColumncomponentIPv6AddressPrefixLenread-writemandatoryThe prefix length for the given address. Note: 'write' is for static ipv6 only.
1.3.6.1.4.1.2.3.51.2.22.32.16.11.6.1.8ColumncomponentIPv6AddressDefaultRouteread-writemandatoryThe default route used for the given address. Note: 'write' is for static ipv6 only.
1.3.6.1.4.1.2.3.51.2.22.32.16.11.7ScalarcomponentIPv6AddressTableCacheTimeoutread-onlymandatoryThe timeout value (in seconds) of the cached data for the table, componentIPv6AddressTable. This value is static (constant) and cannot be set.
1.3.6.1.4.1.2.3.51.2.22.32.20TablecomponentTimeTablenot-accessiblemandatoryTable of Component NTP Configuration.
1.3.6.1.4.1.2.3.51.2.22.32.20.1RowcomponentTimeEntrynot-accessiblemandatoryComponent NTP Configuration entry.
1.3.6.1.4.1.2.3.51.2.22.32.20.1.1ColumncomponentTimeTopologyPathread-onlymandatoryThe unique identifier for a component in this table. The chassis and each installed component is represented by a hardware topology tree, where each node in th…
1.3.6.1.4.1.2.3.51.2.22.32.20.1.2ColumncomponentTimeNameread-onlymandatoryThe name of the component as a null terminated string.
1.3.6.1.4.1.2.3.51.2.22.32.20.1.3ColumncomponentTimeNTPEnableread-writemandatoryThis object allows the user to view the status of, and enable or disable, a component's ability to have it's NTP information updated by the CMM. NOTE: If the c…
1.3.6.1.4.1.2.3.51.2.22.32.20.1.4ColumncomponentTimeNTPFrequencyread-writemandatoryThis object allows the user to view or set the synchronization frequency (in minutes) of the NTP information update from the CMM. NOTE: If the component either…
1.3.6.1.4.1.2.3.51.2.22.32.21ScalarcomponentTimeTableCacheTimeoutread-onlymandatoryThe timeout value (in seconds) of the cached data for the table, componentTimeTable. This value is static (constant) and cannot be set.
1.3.6.1.4.1.2.3.51.2.22.32.26TablecomponentSolTablenot-accessiblemandatoryComponent Serial-over-LAN (SOL) configuration table.
1.3.6.1.4.1.2.3.51.2.22.32.26.1RowcomponentSolEntrynot-accessiblemandatoryComponent Serial-over-LAN (SOL) configuration entry.
1.3.6.1.4.1.2.3.51.2.22.32.26.1.1ColumncomponentSolTopologyPathread-onlymandatoryThe unique identifier for a component in this table. The chassis and each installed component is represented by a hardware topology tree, where each node in th…
1.3.6.1.4.1.2.3.51.2.22.32.26.1.2ColumncomponentSolNameread-onlymandatoryThe name of the component as a null terminated string.
1.3.6.1.4.1.2.3.51.2.22.32.26.1.3ColumncomponentSolEnableread-writemandatoryDisable or enable the Serial-over-LAN (SOL) on a component.
1.3.6.1.4.1.2.3.51.2.22.32.26.1.4ColumncomponentSolIpAddrread-onlydeprecatedThis is deprecated in favor of componentSolIpAddr. IP address of the component derived from the IP address range for the system management processors on the co…
1.3.6.1.4.1.2.3.51.2.22.32.26.1.5ColumncomponentSolSessionStatusread-onlymandatoryStatus of a Serial-over-LAN (SOL) session: solSessionNotReady: No SOL session connected to the component. solSessionReady: There is a SOL session to the compon…
1.3.6.1.4.1.2.3.51.2.22.32.26.1.6ColumncomponentSolCapabilityread-onlymandatoryDisplay whether or not the component supports the Serial-over-LAN (SOL) feature.
1.3.6.1.4.1.2.3.51.2.22.32.26.1.7ColumncomponentSolIpAddr6read-onlymandatoryIPv6 address of the blade.
1.3.6.1.4.1.2.3.51.2.22.32.26.1.8ColumncomponentSolRetryIntervalread-onlymandatoryRetry interval time in miliseconds.
1.3.6.1.4.1.2.3.51.2.22.32.26.1.9ColumncomponentSolRetryCountread-onlymandatoryRetry count.
1.3.6.1.4.1.2.3.51.2.22.32.26.1.10ColumncomponentSolBytesSentread-onlymandatoryNumber of bytes sent.
1.3.6.1.4.1.2.3.51.2.22.32.26.1.11ColumncomponentSolBytesReceivedread-onlymandatoryNumber of bytes received.
1.3.6.1.4.1.2.3.51.2.22.32.26.1.12ColumncomponentSolDestinationMACread-onlymandatoryMAC address of the blade.
1.3.6.1.4.1.2.3.51.2.22.32.26.1.13ColumncomponentSolConsoleUserIdread-onlymandatorySol console user name.
1.3.6.1.4.1.2.3.51.2.22.32.26.1.14ColumncomponentSolConsoleLoginFromread-onlymandatoryThe location information from where the SOL console is logged in.
1.3.6.1.4.1.2.3.51.2.22.32.26.1.15ColumncomponentSolConsoleLoginStartread-onlymandatoryThe time that SOL console starts.
1.3.6.1.4.1.2.3.51.2.22.32.26.1.16ColumncomponentSolConsoleLoginEndread-onlymandatoryThe time that SOL console ends.
1.3.6.1.4.1.2.3.51.2.22.32.27ScalarcomponentSolTableCacheTimeoutread-onlymandatoryThe timeout value (in seconds) of the cached data for the table, componentSolTable. This value is static (constant) and cannot be set.
1.3.6.1.4.1.2.3.51.2.22.37NodecomponentMonitors
1.3.6.1.4.1.2.3.51.2.22.37.1TablecomponentSystemStatusTablenot-accessiblemandatoryTable of component status information.
1.3.6.1.4.1.2.3.51.2.22.37.1.1RowcomponentSystemStatusEntrynot-accessiblemandatoryComponent system status entry
1.3.6.1.4.1.2.3.51.2.22.37.1.1.1ColumncomponentStatusTopologyPathread-onlymandatoryThe unique identifier for a component in this table. The chassis and each installed component is represented by a hardware topology tree, where each node in th…
1.3.6.1.4.1.2.3.51.2.22.37.1.1.2ColumncomponentStatusNameread-onlymandatoryThe name of the component as a null terminated string.
1.3.6.1.4.1.2.3.51.2.22.37.1.1.3ColumncomponentStatusPowerStateread-onlymandatoryIndicates the power state of the component specified.
1.3.6.1.4.1.2.3.51.2.22.37.1.1.4ColumncomponentStatusHealthStateread-onlymandatoryThe system health state for the component. Unknown: Component is in an undefined state. Good: Component is operating normally. Warning: One or more outstanding…
1.3.6.1.4.1.2.3.51.2.22.37.1.1.5ColumncomponentStatusPowerEnableread-onlymandatoryPower enable state for the component.
1.3.6.1.4.1.2.3.51.2.22.37.1.1.6ColumncomponentStatusWakeOnLanEnableread-onlymandatoryWake on LAN enable state for the component.
1.3.6.1.4.1.2.3.51.2.22.37.1.1.7ColumncomponentStatusWidthread-onlymandatoryThe width of the component including any supplement component attached to it
1.3.6.1.4.1.2.3.51.2.22.37.1.1.21ColumncomponentStatusIOCompatibilityread-onlymandatoryI/O compatibility status for the component. The possible values and their meanings are as follows: unknown: This indicates a communication error for the compon…
1.3.6.1.4.1.2.3.51.2.22.37.1.1.22ColumncomponentStatusInventoryReadyread-onlymandatoryWhen a component management controller or the MM is reset, the component inventory data is refreshed in the MM database. This includes items like IBM VPD (e.g.…
1.3.6.1.4.1.2.3.51.2.22.37.1.1.23ColumncomponentStatusBootCountPowerOnTimeBootsread-writemandatoryBlade boot count. This is valid for blade components and otherwise is undefined. Writing this value resets the boot count to zero.
1.3.6.1.4.1.2.3.51.2.22.37.1.1.24ColumncomponentStatusBootCountPowerOnTimeSecsread-writemandatoryBlade power on time in seconds. This is valid for blade components and otherwise is undefined. Writing this value resets the power on time to zero.
1.3.6.1.4.1.2.3.51.2.22.37.2ScalarcomponentSystemStatusTableCacheTimeoutread-onlymandatoryThe timeout value (in seconds) of the cached data for the table, componentSystemStatusTable. This value is static (constant) and cannot be set.
1.3.6.1.4.1.2.3.51.2.22.37.6TablecomponentHealthSummaryTablenot-accessiblemandatoryTable of component health summary information. Contains information about the overall component health status. Each component contains a list of critical or wa…
1.3.6.1.4.1.2.3.51.2.22.37.6.1RowcomponentHealthSummaryEntrynot-accessiblemandatoryComponent health summary entry
1.3.6.1.4.1.2.3.51.2.22.37.6.1.1ColumncomponentHealthTopologyPathread-onlymandatoryThe unique identifier for a component in this table. The chassis and each installed component is represented by a hardware topology tree, where each node in th…
1.3.6.1.4.1.2.3.51.2.22.37.6.1.2ColumncomponentHealthEventIndexread-onlymandatoryAn index for the critical or warning health events for a given component.
1.3.6.1.4.1.2.3.51.2.22.37.6.1.3ColumncomponentHealthSummaryNameread-onlymandatoryThe name of the component as a null terminated string.
1.3.6.1.4.1.2.3.51.2.22.37.6.1.4ColumncomponentHealthSummarySeverityread-onlymandatorySystem health summary severity of an event for the given component.
1.3.6.1.4.1.2.3.51.2.22.37.6.1.5ColumncomponentHealthSummaryDescriptionread-onlymandatorySystem health summary description of an event for the given component.
1.3.6.1.4.1.2.3.51.2.22.37.6.1.6ColumncomponentHealthSummaryDateTimeread-onlymandatorySystem health summary date time of an event for the given component.
1.3.6.1.4.1.2.3.51.2.22.37.6.1.7ColumncomponentHealthSummaryEventIDread-onlymandatorySystem health summary event ID of an event for the given component.
1.3.6.1.4.1.2.3.51.2.22.37.7ScalarcomponentHealthSummaryTableCacheTimeoutread-onlymandatoryThe timeout value (in seconds) of the cached data for the table, componentHealthSummaryTable. This value is static (constant) and cannot be set.
1.3.6.1.4.1.2.3.51.2.22.37.11TablecomponentMACAddressTablenot-accessiblemandatoryTable of MAC address VPD information for each component.
1.3.6.1.4.1.2.3.51.2.22.37.11.1RowcomponentMACAddressEntrynot-accessiblemandatoryComponent MAC address table entry
1.3.6.1.4.1.2.3.51.2.22.37.11.1.1ColumncomponentMACAddressTopologyPathread-onlymandatoryThe unique identifier for a component in this table. The chassis and each installed component is represented by a hardware topology tree, where each node in th…
1.3.6.1.4.1.2.3.51.2.22.37.11.1.2ColumncomponentMACAddressIndexread-onlymandatoryEach component may have one or more MAC address VPD values associated with it, and this index object identifies the particular instance.
1.3.6.1.4.1.2.3.51.2.22.37.11.1.3ColumncomponentMACAddressNameread-onlymandatoryThe name of the component as a null terminated string.
1.3.6.1.4.1.2.3.51.2.22.37.11.1.4ColumncomponentMACAddressread-onlymandatoryThe MAC address VPD value for this component and index. The value is a null terminated string. For IOMs which are members of a stack, this field is not applica…
1.3.6.1.4.1.2.3.51.2.22.37.12ScalarcomponentMACAddressTableCacheTimeoutread-onlymandatoryThe timeout value (in seconds) of the cached data for the table, componentMACAddressTable. This value is static (constant) and cannot be set.
1.3.6.1.4.1.2.3.51.2.22.37.13TablecomponentUniqueIDsTablenot-accessiblemandatoryTable of unique ID information for each component.
1.3.6.1.4.1.2.3.51.2.22.37.13.1RowcomponentUniqueIDsEntrynot-accessiblemandatoryComponent unique ID table entry
1.3.6.1.4.1.2.3.51.2.22.37.13.1.1ColumncomponentUniqueIDsTopologyPathread-onlymandatoryThe unique identifier for a component in this table. The chassis and each installed component is represented by a hardware topology tree, where each node in th…
1.3.6.1.4.1.2.3.51.2.22.37.13.1.2ColumncomponentUniqueIDsIndexread-onlymandatoryEach component may have one or more unique ID values associated with it, and this index object identifies the particular instance.
1.3.6.1.4.1.2.3.51.2.22.37.13.1.3ColumncomponentUniqueIDsNameread-onlymandatoryThe name of the component as a null terminated string.
1.3.6.1.4.1.2.3.51.2.22.37.13.1.4ColumncomponentUniqueIDsTyperead-onlymandatoryType of the unique ID in the object, componentUniqueIDsValue. The type is one of the following: World Wide Name (wwn), Global Unique IDs (guid) or Serial Attac…
1.3.6.1.4.1.2.3.51.2.22.37.13.1.5ColumncomponentUniqueIDsValueread-onlymandatoryThe unique ID value for this component and index. The value is a null terminated string.
1.3.6.1.4.1.2.3.51.2.22.37.14ScalarcomponentUniqueIDsTableCacheTimeoutread-onlymandatoryThe timeout value (in seconds) of the cached data for the table, componentUniqueIDsTable. This value is static (constant) and cannot be set.
1.3.6.1.4.1.2.3.51.2.22.37.16TablecomponentVoltagesTablenot-accessiblemandatoryTable of component voltage sensor information.
1.3.6.1.4.1.2.3.51.2.22.37.16.1RowcomponentVoltagesEntrynot-accessiblemandatoryComponent voltages entry.
1.3.6.1.4.1.2.3.51.2.22.37.16.1.1ColumncomponentVoltagesTopologyPathread-onlymandatoryThe unique identifier for a component in this table. The chassis and each installed component is represented by a hardware topology tree, where each node in th…
1.3.6.1.4.1.2.3.51.2.22.37.16.1.2ColumncomponentVoltagesSensorIndexread-onlymandatoryAn index for the critical or warning health events for a given component.
1.3.6.1.4.1.2.3.51.2.22.37.16.1.3ColumncomponentVoltagesComponentNameread-onlymandatoryThe name of the component as a null terminated string.
1.3.6.1.4.1.2.3.51.2.22.37.16.1.4ColumncomponentVoltagesSensorLabelread-onlymandatoryThe label of the sensor as a null terminated string.
1.3.6.1.4.1.2.3.51.2.22.37.16.1.5ColumncomponentVoltagesSensorValueread-onlymandatoryThe value of the sensor as a null terminated string.
1.3.6.1.4.1.2.3.51.2.22.37.16.1.6ColumncomponentVoltagesLowWarningThresholdread-onlymandatoryThe low warning threshold of the sensor as a null terminated string.
1.3.6.1.4.1.2.3.51.2.22.37.16.1.7ColumncomponentVoltagesHighWarningThresholdread-onlymandatoryThe high warning threshold of the sensor as a null terminated string.
1.3.6.1.4.1.2.3.51.2.22.37.17ScalarcomponentVoltagesTableCacheTimeoutread-onlymandatoryThe timeout value (in seconds) of the cached data for the table, componentVoltagesTable. This value is static (constant) and cannot be set.
1.3.6.1.4.1.2.3.51.2.22.37.21TablecomponentTemperaturesTablenot-accessiblemandatoryTable of component temperature sensor information.
1.3.6.1.4.1.2.3.51.2.22.37.21.1RowcomponentTemperaturesEntrynot-accessiblemandatoryComponent temperatures entry.
1.3.6.1.4.1.2.3.51.2.22.37.21.1.1ColumncomponentTemperaturesTopologyPathread-onlymandatoryThe unique identifier for a component in this table. The chassis and each installed component is represented by a hardware topology tree, where each node in th…
1.3.6.1.4.1.2.3.51.2.22.37.21.1.2ColumncomponentTemperaturesSensorIndexread-onlymandatoryAn index for the temperature Sensors for a given component.
1.3.6.1.4.1.2.3.51.2.22.37.21.1.3ColumncomponentTemperaturesComponentNameread-onlymandatoryThe name of the component as a null terminated string.
1.3.6.1.4.1.2.3.51.2.22.37.21.1.4ColumncomponentTemperaturesSensorLabelread-onlymandatoryThe label of the sensor as a null terminated string.
1.3.6.1.4.1.2.3.51.2.22.37.21.1.5ColumncomponentTemperaturesSensorValueread-onlymandatoryThe value of the sensor as a null terminated string.
1.3.6.1.4.1.2.3.51.2.22.37.21.1.6ColumncomponentTemperaturesWarningThresholdread-onlymandatoryThe warning threshold of the sensor as a null terminated string.
1.3.6.1.4.1.2.3.51.2.22.37.21.1.7ColumncomponentTemperaturesShutdownThresholdread-onlymandatoryThe Shutdown threshold of the sensor as a null terminated string.
1.3.6.1.4.1.2.3.51.2.22.37.21.1.8ColumncomponentTemperaturesWarningResetThresholdread-onlymandatoryThe Warning Reset threshold of the sensor as a null terminated string.
1.3.6.1.4.1.2.3.51.2.22.37.22ScalarcomponentTemperaturesTableCacheTimeoutread-onlymandatoryThe timeout value (in seconds) of the cached data for the table, componentTemperaturesTable. This value is static (constant) and cannot be set.
1.3.6.1.4.1.2.3.51.2.22.37.26TablecomponentIOCompatibilityTablenot-accessiblemandatoryTable of component IO Compatibility information.
1.3.6.1.4.1.2.3.51.2.22.37.26.1RowcomponentIOCompatibilityEntrynot-accessiblemandatoryComponent IO compatibility entry.
1.3.6.1.4.1.2.3.51.2.22.37.26.1.1ColumncomponentIOCompatibilityTopologyPathread-onlymandatoryThe unique identifier for a component in this table. The chassis and each installed component is represented by a hardware topology tree, where each node in th…
1.3.6.1.4.1.2.3.51.2.22.37.26.1.2ColumncomponentIOCompatibilityIOMBayread-onlymandatoryAn index for the IO Compatibility modules for a given component.
1.3.6.1.4.1.2.3.51.2.22.37.26.1.3ColumncomponentIOCompatibilityComponentNameread-onlymandatoryThe name of the component as a null terminated string.
1.3.6.1.4.1.2.3.51.2.22.37.26.1.4ColumncomponentIOCompatibilityIOMPowerread-onlymandatoryThe power state of the module specified in componentIOCompatibilityIOMBay. n/a if module not installed.
1.3.6.1.4.1.2.3.51.2.22.37.26.1.5ColumncomponentIOCompatibilityIOMFabricTyperead-onlymandatoryThe fabric type of the module specified in componentIOCompatibilityIOMBay.
1.3.6.1.4.1.2.3.51.2.22.37.26.1.6ColumncomponentIOCompatibilityFabricOnComponentread-onlymandatoryThe fabric type for this channel on the original component (may be onboard fabric or an expansion card).
1.3.6.1.4.1.2.3.51.2.22.37.26.1.7ColumncomponentIOCompatibilityStatusread-onlymandatoryThe compatibility status between the component and the module specified in componentIOCompatibilityIOMBay. The possible values are: OK: No compatibility issues…
1.3.6.1.4.1.2.3.51.2.22.37.27ScalarcomponentIOCompatibilityTableCacheTimeoutread-onlymandatoryThe timeout value (in seconds) of the cached data for the table, componentIOCompatibilityTable. This value is static (constant) and cannot be set.
1.3.6.1.4.1.2.3.51.2.22.37.31TablenodeConnectivityTablenot-accessiblemandatoryTable of node connectivity information. This table provides information related to the node communication status.
1.3.6.1.4.1.2.3.51.2.22.37.31.1RownodeConnectivityEntrynot-accessiblemandatoryConnectivity information for nodes.
1.3.6.1.4.1.2.3.51.2.22.37.31.1.1ColumnnodeConnectivityIndexread-onlymandatoryNode Connectivity table index.
1.3.6.1.4.1.2.3.51.2.22.37.31.1.2ColumnnodeConnectivityNameread-onlymandatoryThe name of the node as a null terminated string.
1.3.6.1.4.1.2.3.51.2.22.37.31.1.3ColumnnodeConnectivityStatusread-onlymandatoryIndicates the communication status of the node.
1.3.6.1.4.1.2.3.51.2.22.38NodecomponentServiceReset
1.3.6.1.4.1.2.3.51.2.22.38.1TablecomponentServiceResetTablenot-accessiblemandatoryA table providing aux power status and the ability to perform a virtual reseat or hard restart of a component.
1.3.6.1.4.1.2.3.51.2.22.38.1.1RowcomponentServiceResetEntrynot-accessiblemandatoryComponent module power service reset entry
1.3.6.1.4.1.2.3.51.2.22.38.1.1.1ColumncomponentServiceResetTopologyPathread-onlymandatoryThe unique identifier for a row in this table. The chassis and each installed component is represented by a hardware topology tree, where each node in the tree…
1.3.6.1.4.1.2.3.51.2.22.38.1.1.2ColumncomponentServiceResetNameread-onlymandatoryA short text string describing the particular component. For the MM and blades, this name will be the configured name or its serial number if no user configure…
1.3.6.1.4.1.2.3.51.2.22.38.1.1.3ColumncomponentServiceResetStatusread-onlymandatoryStatus of the aux power. A value of auxPowerOff(0) indicates that the componant aux power is off. A value of auxPowerOn(1) indicates that the componant aux pow…
1.3.6.1.4.1.2.3.51.2.22.38.1.1.4ColumncomponentServiceResetCmdread-writemandatoryNOTE: Do not perform this service reset operation on a node that is currently in a maintenance mode state. See componentStatusHealthState in componentSystemSta…
1.3.6.1.4.1.2.3.51.2.22.38.2ScalarcomponentServiceResetTableCacheTimeoutread-onlymandatoryThe timeout value (in seconds) of the cached data for the table, componentServiceResetTable. This value is static (constant) and cannot be set.
1.3.6.1.4.1.2.3.51.2.22.39NodecomponentLEDs
1.3.6.1.4.1.2.3.51.2.22.39.1TablecomponentLEDsTablenot-accessiblemandatoryTable of component LED information. NOTE: Querying objects in this table may take significantly longer than normal, so it is recommended that the query timeout…
1.3.6.1.4.1.2.3.51.2.22.39.1.1RowcomponentLEDsEntrynot-accessiblemandatoryComponent LEDs information entry
1.3.6.1.4.1.2.3.51.2.22.39.1.1.1ColumnledComponentTopologyPathread-onlymandatoryThe unique identifier for a component in this table. The chassis and each installed component is represented by a hardware topology tree, where each node in th…
1.3.6.1.4.1.2.3.51.2.22.39.1.1.2ColumnledComponentNameread-onlymandatoryThe name of the component as a null terminated string.
1.3.6.1.4.1.2.3.51.2.22.39.1.1.3ColumnledComponentFaultread-onlymandatoryIndicates whether the component fault LED is on or off.
1.3.6.1.4.1.2.3.51.2.22.39.1.1.4ColumnledComponentCheckLogread-writemandatoryIndicates whether the component check log information LED is on or off. For Write access, the LED can be turned off only.
1.3.6.1.4.1.2.3.51.2.22.39.1.1.5ColumnledComponentIdentityread-writemandatoryIndicates whether the component identify LED is on, off, or blinking.
1.3.6.1.4.1.2.3.51.2.22.39.2ScalarcomponentLEDsTableCacheTimeoutread-onlymandatoryThe timeout value (in seconds) of the cached data for the table, componentLEDsTable. This value is static (constant) and cannot be set.
1.3.6.1.4.1.2.3.51.2.22.39.9TablecomponentLEDsDetailsTablenot-accessiblemandatoryTable of LED info for each component.
1.3.6.1.4.1.2.3.51.2.22.39.9.1RowcomponentLEDsDetailsEntrynot-accessiblemandatoryComponent LED info table entry
1.3.6.1.4.1.2.3.51.2.22.39.9.1.1ColumncomponentLEDsDetailsTopologyPathread-onlymandatoryThe unique identifier for a component in this table. The chassis and each installed component is represented by a hardware topology tree, where each node in th…
1.3.6.1.4.1.2.3.51.2.22.39.9.1.2ColumncomponentLEDsDetailsIndexread-onlymandatoryEach component may have one or more LEDs and data associated with it, and this index object identifies the particular instance.
1.3.6.1.4.1.2.3.51.2.22.39.9.1.3ColumncomponentLEDsDetailsComponentTyperead-onlymandatoryThe type of the component/subcomponent grouping for this LED.
1.3.6.1.4.1.2.3.51.2.22.39.9.1.4ColumncomponentLEDsDetailsLabelread-onlymandatoryThe text description of the LED.
1.3.6.1.4.1.2.3.51.2.22.39.9.1.5ColumncomponentLEDsDetailsStateread-onlymandatoryThe current state of the LED.
1.3.6.1.4.1.2.3.51.2.22.39.9.1.6ColumncomponentLEDsDetailsLocationread-onlymandatoryThe physical location of this LED on the hardware.
1.3.6.1.4.1.2.3.51.2.22.39.10ScalarcomponentLEDsDetailsTableCacheTimeoutread-onlymandatoryThe timeout value (in seconds) of the cached data for the table, componentLEDsDetailsTable. This value is static (constant) and cannot be set.
1.3.6.1.4.1.2.3.51.2.22.42NodebackupRestore
1.3.6.1.4.1.2.3.51.2.22.42.1ScalarbackupRestoreActionread-writemandatoryStarts the backup or restore operation. It is intended to be write-only. NOTE: This function is only available for SNMPv3.
1.3.6.1.4.1.2.3.51.2.22.42.2ScalarbackupRestoreStatusread-onlymandatoryGet the status of the last backup/restore action which was initiated through SNMP. NOTE: This function is only available for SNMPv3.
1.3.6.1.4.1.2.3.51.2.22.42.3ScalarbackupRestoreMessageread-onlymandatoryGet the status message of the last backup/restore action which was initiated through SNMP. NOTE: This function is only available for SNMPv3.
1.3.6.1.4.1.2.3.51.2.22.42.4ScalarbackupRestoreURIread-writemandatoryContains the fully qualified remote location of the file. A fully qualified remote location contains a supported protocol followed by a colon and two slashes (…
1.3.6.1.4.1.2.3.51.2.22.42.5ScalarbackupRestorePasswordread-writemandatoryPassword used for the encryption/decryption of the sensitive data in the backup file. It is intended to be write-only. NOTE: This function is only available fo…
1.3.6.1.4.1.2.3.51.2.22.42.6ScalarbackupRestoreLogURIread-writemandatoryIndicates the URI address where the log file will be put. It will be used only if the backupRestoreLogPush will be set on push. Contains the fully qualified re…
1.3.6.1.4.1.2.3.51.2.22.42.7ScalarbackupRestoreLogPushread-writemandatoryCauses the restore operation to push the log to the URI address. NOTE: This can be used when restoring without restarting. NOTE: This function is only availabl…
1.3.6.1.4.1.2.3.51.2.23Nodeservice
1.3.6.1.4.1.2.3.51.2.23.3NodebladeServiceData
1.3.6.1.4.1.2.3.51.2.23.3.1TablebladeServiceDataTablenot-accessiblemandatoryTable of blade service data information.
1.3.6.1.4.1.2.3.51.2.23.3.1.1RowbladeServiceDataEntrynot-accessiblemandatoryBlade service data entry
1.3.6.1.4.1.2.3.51.2.23.3.1.1.1ColumnserviceDataIndexread-onlymandatoryBlade service date index.
1.3.6.1.4.1.2.3.51.2.23.3.1.1.2ColumnserviceDataBladeIdread-onlymandatoryThe numeric blade ID.
1.3.6.1.4.1.2.3.51.2.23.3.1.1.3ColumnserviceDataBladeExistsread-onlymandatoryIndicates whether the blade specified exists or not.
1.3.6.1.4.1.2.3.51.2.23.3.1.1.4ColumnserviceDataBladePowerStateread-onlymandatoryIndicates whether the blade specified is powered on or not. If the MM is experiencing a communication problem with the blade, the state may be returned as unkn…
1.3.6.1.4.1.2.3.51.2.23.3.1.1.5ColumnserviceDataBladeNameread-onlymandatoryThe name of the blade as a string.
1.3.6.1.4.1.2.3.51.2.23.3.1.1.7ColumnserviceDataDumpInitiateread-writemandatoryInitiates a type of dump collection to be initiated for the blade. NOTE: Not all blades support this, please check serviceDataDumpCapabilityMask OID to see if …
1.3.6.1.4.1.2.3.51.2.23.3.1.1.8ColumnserviceDataDumpRetrieveread-writemandatoryRetrieve a type of service data file from blade to MM. NOTE: This OID only is valid for the last four bit mask designations listed in the serviceDataDumpCapabi…
1.3.6.1.4.1.2.3.51.2.23.3.1.1.9ColumnserviceDataDumpCapabilityMaskread-onlymandatoryIndicates whether the blade has the capability to trigger service data and if so, which operations are supported and whether the file can be transferred to the…
1.3.6.1.4.1.2.3.51.2.23.3.1.1.10ColumnserviceDataDumpInProgressread-onlymandatoryAn indicator as to whether a blade dump is in progress for the specified blade. This object ONLY applies to dumps that can be triggered by the MM and where the…
1.3.6.1.4.1.2.3.51.2.23.4NodeserviceAdvisor
1.3.6.1.4.1.2.3.51.2.23.4.1NodeautoCallHomeSetup
1.3.6.1.4.1.2.3.51.2.23.4.1.1ScalaracceptLicenseAgreementread-writemandatoryAccept Terms and Conditions of MM Service Advisor. The user will have to accept the terms and conditions before Service Advisor can send diagnostic data to IBM…
1.3.6.1.4.1.2.3.51.2.23.4.1.2ScalarserviceAdvisorEnableread-writemandatoryDisable/Enable IBM Support. The User Agreement must be accepted and the contact information must be set before the IBM Support function of Service Advisor can …
1.3.6.1.4.1.2.3.51.2.23.4.2NodeserviceSupportCenter
1.3.6.1.4.1.2.3.51.2.23.4.2.1ScalaribmSupportCenterread-writemandatoryThe country code for the IBM Support Center. 2 character ISO country code.
1.3.6.1.4.1.2.3.51.2.23.4.3NodecontactInformation
1.3.6.1.4.1.2.3.51.2.23.4.3.1ScalarcompanyNameread-writemandatoryThe organization/company name of the contact person. 1-30 characters.
1.3.6.1.4.1.2.3.51.2.23.4.3.2ScalarcontactNameread-writemandatoryThe name of the contact person.1-30 characters.
1.3.6.1.4.1.2.3.51.2.23.4.3.3ScalarphoneNumberread-writemandatoryThe phone of the contact person. 5-30 characters.
1.3.6.1.4.1.2.3.51.2.23.4.3.4ScalaremailAddressread-writemandatoryThe email of the contact person. It must contain '@' and dot '.' in form userid@hostname (130 characters maximum). The userid can be alphanumeric characters, '…
1.3.6.1.4.1.2.3.51.2.23.4.3.5Scalaraddressread-writemandatoryThe address of the machine location. The information in this field should be of sufficient detail to allow someone to quickly find the chassis when necessary. …
1.3.6.1.4.1.2.3.51.2.23.4.3.6Scalarcityread-writemandatoryThe city of the machine location. 1-30 characters.
1.3.6.1.4.1.2.3.51.2.23.4.3.7Scalarstateread-writemandatoryThe state of the machine location. 2-3 characters.
1.3.6.1.4.1.2.3.51.2.23.4.3.8ScalarpostalCoderead-writemandatoryThe postal code of the location for this system. 1-9 characters, only alphanumeric characters are valid.
1.3.6.1.4.1.2.3.51.2.23.4.3.9ScalarphoneNumberExtread-writemandatoryThe phone number extension of the contact person. 1-30 characters.
1.3.6.1.4.1.2.3.51.2.23.4.3.10ScalaraltContactNameread-writemandatoryThe name of the alternate contact person.1-30 characters.
1.3.6.1.4.1.2.3.51.2.23.4.3.11ScalaraltPhoneNumberread-writemandatoryThe phone of the alternate contact person. 5-30 characters.
1.3.6.1.4.1.2.3.51.2.23.4.3.12ScalaraltPhoneNumberExtread-writemandatoryThe phone number extension of the alternate contact person. 1-30 characters.
1.3.6.1.4.1.2.3.51.2.23.4.3.13ScalaraltEmailAddressread-writemandatoryThe email of the alternate contact person. It must contain '@' and dot '.' in form userid@hostname (130 characters maximum). The userid can be alphanumeric cha…
1.3.6.1.4.1.2.3.51.2.23.4.4NodehttpProxyConfig
1.3.6.1.4.1.2.3.51.2.23.4.4.1ScalarhttpProxyEnableread-writemandatoryDisable/Enable of the HTTP Proxy. Select Enable to use the proxy for call home connections from the MM to IBM. HTTP Proxy is used by the MM when it is not conn…
1.3.6.1.4.1.2.3.51.2.23.4.4.2ScalarhttpProxyLocationread-writemandatoryFully qualified host name or IP address of the HTTP Proxy. Maximum of 63 characters.
1.3.6.1.4.1.2.3.51.2.23.4.4.3ScalarhttpProxyPortread-writemandatoryThe port number of the HTTP Proxy. An integer value from 1 to 65535.
1.3.6.1.4.1.2.3.51.2.23.4.4.4ScalarhttpProxyUserNameread-writemandatoryUser Name of the HTTP Proxy. A maximum of 30 characters string without spaces.
1.3.6.1.4.1.2.3.51.2.23.4.4.5ScalarhttpProxyPasswordread-writemandatoryPassword of the HTTP Proxy. A maximum of 15 characters string without spaces.
1.3.6.1.4.1.2.3.51.2.23.4.5NodeactivityLogs
1.3.6.1.4.1.2.3.51.2.23.4.5.1TableactivityLogTablenot-accessiblemandatoryTable of Service Advisor Activity Log entries information. This table displays the last five events that were generated by the system or user that are called h…
1.3.6.1.4.1.2.3.51.2.23.4.5.1.1RowactivityLogEntrynot-accessiblemandatoryActivity Log table entry. Each entry has the result of the FTP/TFTP Server attempt, the event ID, event source, date and time that event occured, and a text me…
1.3.6.1.4.1.2.3.51.2.23.4.5.1.1.1ColumnactivityLogIndexread-onlymandatoryThe Activity Log index number. For consistent results, view as a table and not as individual entries.
1.3.6.1.4.1.2.3.51.2.23.4.5.1.1.2ColumnactivityLogStringread-onlymandatoryA string of data detailing one Activity Log entry. The text message is from the original entry in the event log. For consistent results, view as a table and no…
1.3.6.1.4.1.2.3.51.2.23.4.5.1.1.3ColumnactivityLogAcknowledgeread-writemandatoryThe acknowledgement of one Activity Log entry as corrected. This field allows the users to set a reminder next to certain events to indicate their awareness of…
1.3.6.1.4.1.2.3.51.2.23.4.5.1.1.4ColumnactivityLogAttributeread-onlymandatoryA string of data detailing one Activity Log entry's attribute. Status PENDING indicates that the system is preparing for the event to be called home by collect…
1.3.6.1.4.1.2.3.51.2.23.5NodeautoFTPSetup
1.3.6.1.4.1.2.3.51.2.23.5.1ScalarautoFTPCallModeread-writemandatoryThis field specifies the automated problem reporting mode. Automated problem reporting mode allows the MM to automatically put service data to a specified serv…
1.3.6.1.4.1.2.3.51.2.23.5.2ScalarautoFTPCallAddrread-writemandatoryThis field specifies the remote server address of FTP and TFTP. It should be fully qualified hostname or IP address.
1.3.6.1.4.1.2.3.51.2.23.5.3ScalarautoFTPCallPortread-writemandatoryThis field specifies the port on remote FTP/TFTP server for data transmission.
1.3.6.1.4.1.2.3.51.2.23.5.4ScalarautoFTPCallUserIDread-writemandatoryThis field specifies the user account to login remote FTP server.
1.3.6.1.4.1.2.3.51.2.23.5.5ScalarautoFTPCallPasswordread-writemandatoryThis field specifies the password to login remote FTP server.
1.3.6.1.4.1.2.3.51.2.23.6NodecallHomeExclusionEvents
1.3.6.1.4.1.2.3.51.2.23.6.1TablereadCallHomeExclusionEventTablenot-accessiblemandatoryTable of Call Home Exclusion Event entries information.
1.3.6.1.4.1.2.3.51.2.23.6.1.1RowreadCallHomeExclusionEventEntrynot-accessiblemandatoryCall Home Exclusion Event table entry
1.3.6.1.4.1.2.3.51.2.23.6.1.1.1ColumnreadCallHomeExclusionEventIndexread-onlymandatoryThe index number of one Call Home Exclusion Event. For consistent results, view as a table and not as individual entries.
1.3.6.1.4.1.2.3.51.2.23.6.1.1.2ColumnreadCallHomeExclusionEventIDread-onlymandatoryThe Event ID of one Call Home Exclusion Event entry. For consistent results, view as a table and not as individual entries.
1.3.6.1.4.1.2.3.51.2.23.6.2ScalaraddCallHomeExclusionEventread-writemandatoryAdd one call home Event ID into the Call Home Exclusion List. The Event ID is an 8-digit hexadecimal number (0-F) with an optional prefix of '0x' or '0X'. An E…
1.3.6.1.4.1.2.3.51.2.23.6.3ScalarrmCallHomeExclusionEventread-writemandatoryRemove one call home Event ID from the Call Home Exclusion List. The Event ID is an 8-digit hexadecimal number (0-F) with an optional prefix of '0x' or '0X'. A…
1.3.6.1.4.1.2.3.51.2.23.6.4ScalarrmAllCallHomeExclusionEventread-writemandatoryRemove all Event IDs from the Call Home Exclusion List. Events on the exclusion list can not be removed if autoFtpMode is disabled. If Service Advisor Terms an…
1.3.6.1.4.1.2.3.51.2.23.10NodecomponentPowerServiceReset
1.3.6.1.4.1.2.3.51.2.23.10.1TablebladePowerServiceResetTablenot-accessiblemandatoryA table providing aux power status and the ability to perform a virtual reseat or hard restart of a blade.
1.3.6.1.4.1.2.3.51.2.23.10.1.1RowbladePowerServiceResetEntrynot-accessiblemandatoryBlade power service reset entry
1.3.6.1.4.1.2.3.51.2.23.10.1.1.1ColumnbladePowerServiceResetIndexread-onlymandatoryBlade power service reset index.
1.3.6.1.4.1.2.3.51.2.23.10.1.1.2ColumnbladePowerServiceResetBladeIdread-onlymandatoryThe numeric blade slot number.
1.3.6.1.4.1.2.3.51.2.23.10.1.1.3ColumnbladePowerServiceResetStatusread-onlymandatoryStatus of the aux power. A value of auxPowerOff(0) indicates that the blade aux power is off. A value of auxPowerOn(1) indicates that the blade aux power is on.
1.3.6.1.4.1.2.3.51.2.23.10.1.1.4ColumnbladePowerServiceResetCmdread-writemandatoryNOTE: Do not perform this service reset operation on a node that is currently in a maintenance mode state. See bladeHealthState in bladeSystemStatusTable for m…
1.3.6.1.4.1.2.3.51.2.23.10.2TablesmPowerServiceResetTablenot-accessiblemandatoryA table providing aux power status and the ability to perform a virtual reseat or hard restart of a switch.
1.3.6.1.4.1.2.3.51.2.23.10.2.1RowsmPowerServiceResetEntrynot-accessiblemandatorySwitch module power service reset entry
1.3.6.1.4.1.2.3.51.2.23.10.2.1.1ColumnsmPowerServiceResetIndexread-onlymandatorySwitch module power service reset index.
1.3.6.1.4.1.2.3.51.2.23.10.2.1.2ColumnsmPowerServiceResetSwitchIdread-onlymandatoryThe switch module numeric identifier.
1.3.6.1.4.1.2.3.51.2.23.10.2.1.3ColumnsmPowerServiceResetStatusread-onlymandatoryStatus of the aux power power. A value of auxPowerOff(0) indicates that the switch aux power is off. A value of auxPowerOn(1) indicates that the switch aux pow…
1.3.6.1.4.1.2.3.51.2.23.10.2.1.4ColumnsmPowerServiceResetCmdread-writemandatoryTo reset the auxiliary power on a switch component, set this object to resetVirtualReseatOperation(1). This will toggle the auxiliary power to the switch and s…
1.3.6.1.4.1.2.3.51.2.23.15NodecomponentServiceData
1.3.6.1.4.1.2.3.51.2.23.15.1TablecomponentServiceDataTablenot-accessiblemandatoryTable of component service data information.
1.3.6.1.4.1.2.3.51.2.23.15.1.1RowcomponentServiceDataEntrynot-accessiblemandatoryComponent service data entry
1.3.6.1.4.1.2.3.51.2.23.15.1.1.1ColumncomponentServiceDataTopologyPathread-onlymandatoryThe unique identifier for a component in this table. The chassis and each installed component is represented by a hardware topology tree, where each node in th…
1.3.6.1.4.1.2.3.51.2.23.15.1.1.2ColumncomponentServiceDataComponentNameread-onlymandatoryThe name of the component as a null terminated string.
1.3.6.1.4.1.2.3.51.2.23.15.1.1.3ColumncomponentServiceDataDumpInitiateread-writemandatoryInitiates a type of dump collection to be initiated for the component and sent to the MM. NOTE: Not all components support this, please check componentServiceD…
1.3.6.1.4.1.2.3.51.2.23.15.1.1.4ColumncomponentServiceDataDumpRetrieveread-writemandatoryRetrieve a type of service data file from component to MM. NOTE: This OID only is valid for the last four bit mask designations listed in the componentServiceD…
1.3.6.1.4.1.2.3.51.2.23.15.1.1.5ColumncomponentServiceDataDumpCapabilityMaskread-onlymandatoryIndicates whether the component has the capability to trigger service data and if so, which operations are supported and whether the file can be transferred to…
1.3.6.1.4.1.2.3.51.2.23.15.1.1.6ColumncomponentServiceDataDumpInProgressread-onlymandatoryAn indicator as to whether a component dump is in progress for the specified component. This object ONLY applies to dumps that can be triggered by the MM and w…
1.3.6.1.4.1.2.3.51.2.23.15.1.1.7ColumncomponentServiceDataStatusread-onlymandatoryA status indicator for dump progress. This object ONLY applies to switch modules dumps.
1.3.6.1.4.1.2.3.51.2.23.15.1.1.8ColumncomponentServiceDataStatusDetailsread-onlymandatoryThe failure status as a null terminated string. This object ONLY applies to switch modules dumps.
1.3.6.1.4.1.2.3.51.2.23.15.2ScalarcomponentServiceDataTableCacheTimeoutread-onlymandatoryThe timeout value (in seconds) of the cached data for the table, componentServiceDataTable. This value is static (constant) and cannot be set.
1.3.6.1.4.1.2.3.51.2.23.21NodedownloadMMServiceData
1.3.6.1.4.1.2.3.51.2.23.21.1ScalardownloadMMServiceDataFileCreateAndDownloadread-writemandatorySpecifying this string initiates the generation of the FFDC (First-Failure Data Capture) data collection (compressed group of files) for the CMM and the downlo…
1.3.6.1.4.1.2.3.51.2.23.21.2ScalardownloadMMServiceDataStatusread-onlymandatoryAn indicator as to whether the FFDC generation and download is in progress. To initiate this process, set the object, downloadMMServiceDataFileCreateAndDownloa…
1.3.6.1.4.1.2.3.51.2.23.21.3ScalardownloadMMServiceDataResultread-writemandatoryAn indicator as to whether the FFDC generation and download was successful. The FFDC generation and download is started by setting a destination filename with …
1.3.6.1.4.1.2.3.51.2.23.21.4ScalardownloadMMServiceDataCancelDownloadread-writemandatorySet this object to 'cancel(1)' to stop the FFDC file download process. 'cancel(1)' is the only valid value that may be set. The value of this object will be 'c…
1.3.6.1.4.1.2.3.51.2.24Nodescaling
1.3.6.1.4.1.2.3.51.2.24.1TablescalableComplexTablenot-accessiblemandatoryTable of scalable complex information. This table provides information related to the scalable complexes installed in the chassis.
1.3.6.1.4.1.2.3.51.2.24.1.1RowscalableComplexEntrynot-accessiblemandatoryScalable complex information.
1.3.6.1.4.1.2.3.51.2.24.1.1.1ColumnscalableComplexTopologyPathread-onlymandatoryThe unique identifier for a component in this table. The chassis and each installed component is represented by a hardware topology tree, where each node in th…
1.3.6.1.4.1.2.3.51.2.24.1.1.2ColumnscalableComplexIdentifierread-onlymandatoryThe unique numeric identifier for a complex installed in the chassis.
1.3.6.1.4.1.2.3.51.2.24.1.1.3ColumnscalableComplexNodeNameread-onlymandatoryThe name of the node as a null terminated string.
1.3.6.1.4.1.2.3.51.2.24.1.1.4ColumnscalableComplexNodeHealthStateread-onlymandatoryThe system health state for the component. Unknown: Component is in an undefined state. Good: Component is operating normally. Warning: One or more outstanding…
1.3.6.1.4.1.2.3.51.2.24.1.1.5ColumnscalableComplexNodePowerStateread-onlymandatoryIndicates the power state of the node.
1.3.6.1.4.1.2.3.51.2.24.1.1.6ColumnscalableComplexNodeResourcesread-onlymandatoryA string providing a summary overview of the resources provided by this node.
Type Definitions
NameSyntaxStatusDescription
InetAddressIPv6OCTET STRING (SIZE (16)) EntryStatus ::= INTEGER { valid(1), createRequest(2), underCreation(3), invalid(4) }currentRepresents an IPv6 network address. Since MIB browsers may require different formats, the address is expected to be the 16 byte address in network-byte order, and shortened formats such as 0::0 are not accepted in SET o…