CONTIVITY-TRAPS-V1-MIB
178 objects
This MIB defines the traps, and bind objects used in the traps, that are sent by the VPN Router.
Imported Objects
| NEWOAK-MIB | contivity |
| RFC-1212 | OBJECT-TYPE |
| RFC-1215 | TRAP-TYPE |
| RFC1155-SMI | IpAddress |
| RFC1213-MIB | DisplayString ifAdminStatus ifDescr ifIndex ifOperStatus ifType snmp sysName sysObjectID |
| SNMPv2-SMI | MODULE-IDENTITY |
| OID | Name | Access | Status | Description |
|---|---|---|---|---|
| 1.3.6.1.2.1.11.0 | NodecoldStart | A coldStart trap signifies that the SNMPv2 entity, acting in an agent role, is reinitializing itself and that its configuration may have been altered. | ||
| 1.3.6.1.2.1.11.2 | NodelinkDown | A linkDown trap signifies that the sending protocol entity recognizes a failure in one of the communication links represented in the agent's configuration. Var… | ||
| 1.3.6.1.2.1.11.3 | NodelinkUp | A linkUp trap signifies that the sending protocol entity recognizes that one of the communication links represented in the agent's configuration has come up. V… | ||
| 1.3.6.1.2.1.11.5 | NodeauthenticationFailure | An authenticationFailure trap signifies that the SNMPv2 entity, acting in an agent role, has received a protocol message that is not properly authenticated. Th… | ||
| 1.3.6.1.4.1.2505.1.0 | IdentitycontivityTrapsV1 | This MIB defines the traps, and bind objects used in the traps, that are sent by the VPN Router. | ||
| 1.3.6.1.4.1.2505.1.1 | NodehardwareCESTrapInfo | |||
| 1.3.6.1.4.1.2505.1.1.1 | ScalarhardDisk1Status | read-only | mandatory | Hard Disk Number 1 Status. Possible Values: Warning: Hard Disk 1 : Device /ide1/ not available Warning: Hard Disk 1 : Utilization exceeds 75%% on /ide1/ Alert:… |
| 1.3.6.1.4.1.2505.1.1.2 | ScalarhardDisk0Status | read-only | mandatory | Hard Disk Number 0 Status. Possible Values: Warning: Hard Disk 0 : Device /ide0/ not available Warning: Hard Disk 0 : Utilization exceeds 75%% on /ide0/ Alert:… |
| 1.3.6.1.4.1.2505.1.1.3 | ScalarmemoryUsage | read-only | mandatory | Memory Usage Status. Possible Values: Warning: Memory Usage : Utilization exceeds 75% Alert: Memory Usage : Utilization exceeds 87.5% |
| 1.3.6.1.4.1.2505.1.1.4 | ScalarlanCardStatus | read-only | mandatory | Status of any LAN cards on the system. Possible Values: Please note that X corresponds to the Xth slot in the system. Please note that Y corresponds to the rel… |
| 1.3.6.1.4.1.2505.1.1.5 | ScalarcpuTwoStatus | read-only | mandatory | Status of second CPU. Possible Values: Alert: CPU 2: Program load failed; Alert: CPU 2: Bootup did not complete; Alert: CPU 2: Communication lost; Alert: CPU 2… |
| 1.3.6.1.4.1.2505.1.1.6 | ScalarfanOneStatus | read-only | mandatory | Status of the first CPU fan. Possible Values: Alert: CPU One Fan: Fan not functioning; This indicates that the fan on the primary processor is running either b… |
| 1.3.6.1.4.1.2505.1.1.7 | ScalarfanTwoStatus | read-only | mandatory | Status of the second CPU fan Possible Values: Alert: CPU Two Fan: Fan not functioning; This indicates that the fan on the auxiliary processor is running either… |
| 1.3.6.1.4.1.2505.1.1.8 | ScalarchassisFanStatus | read-only | mandatory | Status of the chassis fan. Possible Values: Alert: Chassis Fan: Fan not functioning; Alert: Chassis Fan 2: Fan not functioning; This indicates that one of the … |
| 1.3.6.1.4.1.2505.1.1.9 | ScalarfiveVoltsPositive | read-only | mandatory | Status of +5 Volt power. Possible Values: Alert: Voltage 5 V Plus: Voltage out of range; The supplied voltage to the system is not within the the specified ran… |
| 1.3.6.1.4.1.2505.1.1.10 | ScalarfiveVoltsMinus | read-only | mandatory | Status of -5 Volt power. Possible Values: Alert: Voltage 5 V Minus: Voltage out of range; The supplied voltage to the system is not within the the specified ra… |
| 1.3.6.1.4.1.2505.1.1.11 | ScalarthreeVoltsPositive | read-only | mandatory | Status of +3 Volt power. Possible Values: Alert: Voltage 3.3 V Plus: Voltage out of range; The supplied voltage to the system is not within the the specified r… |
| 1.3.6.1.4.1.2505.1.1.12 | ScalartwoDotFiveVA | read-only | mandatory | Status of 2.5VA power. Possible Values: Alert: Voltage 2.5 VA: Voltage out of range; This is the voltage supplied to the primary processor. The supplied voltag… |
| 1.3.6.1.4.1.2505.1.1.13 | ScalartwoDotFiveVB | read-only | mandatory | Status of 2.5VB power. Possible Values: Alert: Voltage 2.5 VB: Voltage out of range; This is the voltage supplied to the seconary processor. The supplied volta… |
| 1.3.6.1.4.1.2505.1.1.14 | ScalartwelveVoltsPositive | read-only | mandatory | Status of +12 Volt power. Possible Values: Alert: Voltage 12 V Plus: Voltage out of range; The supplied voltage to the system is not within the the specified r… |
| 1.3.6.1.4.1.2505.1.1.15 | ScalartwelveVoltsMinus | read-only | mandatory | Status of -12 Volt power. Possible Values: Alert: Voltage 12 V Minus: Voltage out of range; The supplied voltage to the system is not within the the specified … |
| 1.3.6.1.4.1.2505.1.1.16 | ScalarnormalTemperature | read-only | mandatory | Status of normal temperature reading. Possible Values: Alert: Normal Temperature: Normal temperature out of range; This indicates that the box is running above… |
| 1.3.6.1.4.1.2505.1.1.17 | ScalarcriticalTemperature | read-only | mandatory | Status of critical temperature reading. Possible Values: Alert: Critical Temperature: Critial temperature out of range; This indicates that the box is running … |
| 1.3.6.1.4.1.2505.1.1.18 | ScalarchassisIntrusion | read-only | mandatory | The chassis intrusion sensor indicates that the unit has been opened. Possible Values: Alert: Intrusion: Box has been opened; The cover to the CES has been ope… |
| 1.3.6.1.4.1.2505.1.1.19 | ScalardualPowerSupply | read-only | mandatory | Status of the redundant power supplies. Possible Values: Alert: Dual Power Supply: Redundant supply faulted This indicates that, on systems with redundant powe… |
| 1.3.6.1.4.1.2505.1.1.20 | Scalart1WANStatus | read-only | mandatory | Status of T1 WAN card(s). Possible Values: For Wanic support: Alert: Invalid Device X Warning: Device WanicX disabled Alert: Device WanicX down Warning: Device… |
| 1.3.6.1.4.1.2505.1.1.21 | Scalart3WANStatus | read-only | mandatory | Status of T3 WAN card Possible Values: Alert: Invalid Index X Warning: Device HSSIX disabled Alert: Device HSSIX down Warning: Device HSSIX not initialized Ale… |
| 1.3.6.1.4.1.2505.1.1.22 | ScalarhwAccelStatus | read-only | mandatory | Status of hardware accelerator card. |
| 1.3.6.1.4.1.2505.1.1.24 | Scalarv90WANStatus | read-only | mandatory | Status of V.90 Interface card Possible Values: Please note that X corresponds to the unit number of the card. Alert: V.90 Invalid index X Disabled: Device IntM… |
| 1.3.6.1.4.1.2505.1.1.25 | ScalarbriWANStatus | read-only | mandatory | Status of ISDN BRI Interface card Possible Values: Please note that X corresponds to the unit number of the card. Alert: BRI Invalid index X Alert: Device BRI-… |
| 1.3.6.1.4.1.2505.1.1.26 | ScalarserUartStatus | read-only | mandatory | Status of Serial (COM) port/interface Possible Values: Please note that X corresponds to the unit number of the serial interface Alert: COM port Invalid index … |
| 1.3.6.1.4.1.2505.1.1.27 | ScalaradslWANStatus | read-only | mandatory | Status of ADI ADSL card Possible Values: Please note that X corresponds to the unit number of the serial interface Alert: Invalid index X Alert: Device ADIADSL… |
| 1.3.6.1.4.1.2505.1.1.1001 | NodehardDisk1StatusTrap | Hard Disk Number 1 Status | ||
| 1.3.6.1.4.1.2505.1.1.1002 | NodehardDisk0StatusTrap | Hard Disk Number 0 Status | ||
| 1.3.6.1.4.1.2505.1.1.1003 | NodememoryUsageTrap | Memory Usage Status | ||
| 1.3.6.1.4.1.2505.1.1.1004 | NodelanCardStatusTrap | Status of any LAN cards on the system | ||
| 1.3.6.1.4.1.2505.1.1.1005 | NodecpuTwoStatusTrap | Status of second CPU. | ||
| 1.3.6.1.4.1.2505.1.1.1006 | NodefanOneStatusTrap | Status of the first CPU fan | ||
| 1.3.6.1.4.1.2505.1.1.1007 | NodefanTwoStatusTrap | Status of the second CPU fan | ||
| 1.3.6.1.4.1.2505.1.1.1008 | NodechassisFanStatusTrap | Status of the chassis fan. | ||
| 1.3.6.1.4.1.2505.1.1.1009 | NodefiveVoltsPosStatusTrap | Status of the +5 Volt power | ||
| 1.3.6.1.4.1.2505.1.1.10010 | NodefiveVoltsMinusTrap | Status of -5 Volt power | ||
| 1.3.6.1.4.1.2505.1.1.10011 | NodethreeVoltsPositiveTrap | Status of +3 Volt power | ||
| 1.3.6.1.4.1.2505.1.1.10012 | NodetwoDotFiveVATrap | Status of 2.5VA power | ||
| 1.3.6.1.4.1.2505.1.1.10013 | NodetwoDotFiveVBTrap | Status of 2.5VB power | ||
| 1.3.6.1.4.1.2505.1.1.10014 | NodetwelveVoltsPositveTrap | Status of +12 Volt power | ||
| 1.3.6.1.4.1.2505.1.1.10015 | NodetwelveVoltsMinsTrap | Status of -12 Volt power | ||
| 1.3.6.1.4.1.2505.1.1.10016 | NodenormalTemperatureTrap | Status of the normal temperature reading | ||
| 1.3.6.1.4.1.2505.1.1.10017 | NodecriticalTemperatureTrap | Status of the critical temperature reading | ||
| 1.3.6.1.4.1.2505.1.1.10018 | NodechassisIntrusionTrap | The chassis intrusion sensor indicates that the unit has been physically opened | ||
| 1.3.6.1.4.1.2505.1.1.10019 | NodedualPowerSupplyTrap | Status of the redundant power supplies | ||
| 1.3.6.1.4.1.2505.1.1.10020 | Nodet1WANStatusTrap | Status of T1 WAN card(s). Possible Values: For Wanic support: Alert: Invalid Device X Warning: Device WanicX disabled Alert: Device WanicX down Warning: Device… | ||
| 1.3.6.1.4.1.2505.1.1.10021 | Nodet3WANStatusTrap | Status of T3 WAN card Possible Values: Alert: Invalid Index X Warning: Device HSSIX disabled Alert: Device HSSIX down Warning: Device HSSIX not initialized Ale… | ||
| 1.3.6.1.4.1.2505.1.1.10022 | NodehwAccelTrap | Status of hardware accelerator card. Possible Values: Invalid hardware accelerator unit %d; Unknown hardware accelerator unit %d; Healthy: Bulk Accelerator in … | ||
| 1.3.6.1.4.1.2505.1.1.10024 | Nodev90WANStatusTrap | Status of V.90 Interface card Possible Values: Please note that X corresponds to the unit number of the card. Alert: V.90 Invalid index X Disabled: Device IntM… | ||
| 1.3.6.1.4.1.2505.1.1.10025 | NodebriWANStatusTrap | Status of V.90 Interface card Possible Values: Please note that X corresponds to the unit number of the card. Alert: BRI Invalid index X Alert: Device BRI-X no… | ||
| 1.3.6.1.4.1.2505.1.1.10026 | NodeserUartStatusTrap | Status of Serial (COM) port/interface Possible Values: Please note that X corresponds to the unit number of the serial interface Alert: COM port Invalid index … | ||
| 1.3.6.1.4.1.2505.1.1.10027 | NodeadslWANStatusTrap | Status of ADI ADSL card Possible Values: Please note that X corresponds to the unit number of the serial interface Alert: Invalid index X Alert: Device ADIADSL… | ||
| 1.3.6.1.4.1.2505.1.2 | NodeserverCESTrapInfo | |||
| 1.3.6.1.4.1.2505.1.2.1 | ScalarradiusAcctServer | read-only | mandatory | Status of External Radius Accounting Server. Possible Values: Warning: RADIUS Accounting Server: Server not configured Alert: RADIUS Accounting Server: Error A… |
| 1.3.6.1.4.1.2505.1.2.2 | ScalarbackupServer | read-only | mandatory | Status of External Disk Backup Server. Possible Values: Warning: Auto Backup Servers: Server not configured. Warning: Auto Backup Servers: Can't backup to xxx … |
| 1.3.6.1.4.1.2505.1.2.3 | ScalardiskRedundency | read-only | mandatory | Status of Local Disk Redundency. Possible Values: Alert: Disk Redundancy: Not Configured Alert: Disk Redundancy: Error |
| 1.3.6.1.4.1.2505.1.2.4 | ScalarintLDAPServer | read-only | mandatory | Status of Internal LDAP Server. Possible Values: Warning : Internal LDAP Server : Restore in progress Alert : Internal LDAP Server : Server is down |
| 1.3.6.1.4.1.2505.1.2.5 | ScalarloadBalancingServer | read-only | mandatory | Status of Load Balancing Server. Possible Values: Disabled: Load Balancing Service: Server not enabled; Warning: Load Balancing Service: Timed out waiting for … |
| 1.3.6.1.4.1.2505.1.2.6 | ScalardnsServer | read-only | mandatory | Status of DNS Server. Possible Values: Warning: DNS Servers : Error Warning: DNS Servers : Operational Alert: DNS Servers : Configured Alert: DNS Servers : Err… |
| 1.3.6.1.4.1.2505.1.2.7 | ScalarsnmpServer | read-only | mandatory | Status of SNMP Server. Possible Values: Warning: SNMP Servers : Error Warning: SNMP Servers : Can't reach xxx.xxx.xxx.xxx or yyy.yyy.yyy.yyy Alert: SNMP Server… |
| 1.3.6.1.4.1.2505.1.2.8 | ScalaripAddressPool | read-only | mandatory | Status of the IP address pool. Possible Values: Warning: IP Address Pool : Reserved address count is low. Warning: IP Address Pool : DHCP server(s) unavailable… |
| 1.3.6.1.4.1.2505.1.2.9 | ScalarextLDAPServer | read-only | mandatory | Status of External LDAP Server. Possible Values: Warning: External LDAP Servers : Server is down Alert: External LDAP Servers : Server is down The values have … |
| 1.3.6.1.4.1.2505.1.2.10 | ScalarradiusAuthServer | read-only | mandatory | Status of Radius Authentication Server. Possible Values: Warning: RADIUS Authentication Servers : Error Alert: RADIUS Authentication Servers : Error The values… |
| 1.3.6.1.4.1.2505.1.2.11 | ScalarcertificateServer | read-only | mandatory | Status of Certificates Validity. Possible Values: Alert: Certificates Validity: All certificates are going to expire/expired; Warning: Certificates Validity: O… |
| 1.3.6.1.4.1.2505.1.2.12 | ScalarextLDAPAuthServer | read-only | mandatory | Status of External LDAP Authentication Server. Possible Values: Warning: External LDAP Authentication Server: Server is down(indicates at least one server is n… |
| 1.3.6.1.4.1.2505.1.2.13 | ScalarcmpServer | read-only | mandatory | Status of CMP Server. Possible Values: One/more Certificate Requests error: there is at least one request error; One/more Certificate Requests processing: ther… |
| 1.3.6.1.4.1.2505.1.2.14 | ScalardhcpServer | read-only | mandatory | Status of DHCP Server. Possible Values: Disabled: DHCP Server is Disabled Alert: DHCP Server is NOT configured Alert: DHCP Server is configured and operational… |
| 1.3.6.1.4.1.2505.1.2.15 | ScalarsshServer | read-only | mandatory | Status of SSH Server. Possible Values: Disabled : Healthy : Warning : Warning : Warning : Alert : |
| 1.3.6.1.4.1.2505.1.2.16 | ScalarntpServer | read-only | mandatory | Status of NTP Server. Possible Values: Disabled : Healthy : Warning : Warning : Warning : Warning : Warning : Warning : Warning : |
| 1.3.6.1.4.1.2505.1.2.17 | ScalarospfServer | read-only | mandatory | Status of OSPF Server. Possible Values: Disabled : Warning : Warning : Alert : Alert : Healthy : |
| 1.3.6.1.4.1.2505.1.2.18 | ScalarclipServer | read-only | mandatory | Status of Circuitless IP. Possible Values: Disabled : Healthy : |
| 1.3.6.1.4.1.2505.1.2.19 | ScalardhcprelayServer | read-only | mandatory | Status of DHCP Relay Server. Possible Values: Alert : Alert : Alert : Healthy : |
| 1.3.6.1.4.1.2505.1.2.20 | ScalargdsServer | read-only | mandatory | Status of Global Demand Services Services. Possible Values: Healthy : Disabled : |
| 1.3.6.1.4.1.2505.1.2.21 | ScalardemandintfServer | read-only | mandatory | Status of Demand Interface. Possible Values: Healthy : Healthy : Healthy : Healthy : Disabled : |
| 1.3.6.1.4.1.2505.1.2.22 | ScalarcrlServer | read-only | mandatory | Status of CRL Server. Possible Values: Healthy : Alert : Warning : Warning : Disabled : |
| 1.3.6.1.4.1.2505.1.2.23 | ScalarocspServer | read-only | mandatory | Status of OCSP Server. Possible Values: Disabled : Alert : Warning : Warning : Healthy : |
| 1.3.6.1.4.1.2505.1.2.3001 | NoderadiusAcctServerTrap | Status of External Radius Accounting Server | ||
| 1.3.6.1.4.1.2505.1.2.3002 | NodebackupServerTrap | Status of External Disk Backup Server | ||
| 1.3.6.1.4.1.2505.1.2.3003 | NodediskRedundencyTrap | Status of Local Disk Redundency | ||
| 1.3.6.1.4.1.2505.1.2.3004 | NodeintLDAPServerTrap | Status of Internal LDAP Server | ||
| 1.3.6.1.4.1.2505.1.2.3005 | NodeloadBalancingServerTrap | Status of Load Balancing Server | ||
| 1.3.6.1.4.1.2505.1.2.3006 | NodednsServerTrap | Status of DNS Server | ||
| 1.3.6.1.4.1.2505.1.2.3007 | NodesnmpServerTrap | Status of SNMP Server | ||
| 1.3.6.1.4.1.2505.1.2.3008 | NodeipAddressPoolTrap | Status of the IP address pool | ||
| 1.3.6.1.4.1.2505.1.2.3009 | NodeextLDAPServerTrap | Status of External LDAP Server | ||
| 1.3.6.1.4.1.2505.1.2.30010 | NoderadiusAuthServerTrap | Status of Radius Authentication Server | ||
| 1.3.6.1.4.1.2505.1.2.30011 | NodecertificateServerTrap | Status of Certificates Validity Possible Values: Healthy: Certificates Validity: Operational; Alert: Certificates Validity: All certificates are going to expir… | ||
| 1.3.6.1.4.1.2505.1.2.30012 | NodeextLDAPAuthServerTrap | Status of External LDAP Authentication Server. Possible Values: Warning: External LDAP Authentication Server: Server is down(indicates at least one server is n… | ||
| 1.3.6.1.4.1.2505.1.2.30013 | NodecmpServerTrap | Status of CMP Server. Possible Values: One/more Certificate Requests error: there is at least one request error; One/more Certificate Requests processing: ther… | ||
| 1.3.6.1.4.1.2505.1.2.30014 | NodedhcpServerTrap | Status of DHCP Server Possible Values: Disabled: DHCP Server is Disabled Alert: DHCP Server is NOT configured Alert: DHCP Server is configured and operational,… | ||
| 1.3.6.1.4.1.2505.1.2.30015 | NodesshServerTrap | Status of SSH Server. | ||
| 1.3.6.1.4.1.2505.1.2.30016 | NodentpServerTrap | Status of NTP Server. | ||
| 1.3.6.1.4.1.2505.1.2.30017 | NodeospfServerTrap | Status of OSPF Server. | ||
| 1.3.6.1.4.1.2505.1.2.30018 | NodeclipServerTrap | Status of Circuitless IP. | ||
| 1.3.6.1.4.1.2505.1.2.30019 | NodedhcprelayServerTrap | Status of DHCP Relay Server. | ||
| 1.3.6.1.4.1.2505.1.2.30020 | NodegdsServerTrap | Status of Global Demand Services Services. | ||
| 1.3.6.1.4.1.2505.1.2.30021 | NodedemandintfServerTrap | Status of Demand Interface. | ||
| 1.3.6.1.4.1.2505.1.2.30022 | NodecrlServerTrap | Status of CRL Server. | ||
| 1.3.6.1.4.1.2505.1.2.30023 | NodeocspServerTrap | Status of OCSP Server. | ||
| 1.3.6.1.4.1.2505.1.3 | NodeserviceCESTrapInfo | |||
| 1.3.6.1.4.1.2505.1.3.1 | ScalarnetBuffers | read-only | mandatory | Network buffer usage. Possible Values: Warning: Buffer Usage : Utilization exceeds 75% Alert: Buffer Usage : Utilization exceeds 87.5% |
| 1.3.6.1.4.1.2505.1.3.2 | ScalarfireWall | read-only | mandatory | Status of internal firewall. Possible Values: Disabled: Firewall: Firewall disabled; Disabled: Firewall: Firewall stopped; Warning: Firewall: Current Firewall … |
| 1.3.6.1.4.1.2505.1.3.3 | ScalarfipsStatus | read-only | mandatory | Status of FIPS. Possible Values: Warning: FIPS: Random generator test failed; Warning: FIPS: DESMAC check on executables Failed; Warning: FIPS: DES KAT Test Fa… |
| 1.3.6.1.4.1.2505.1.3.4 | ScalarlicensingStatus | read-only | mandatory | Status of temporary SW Licenses. Possible Values: Warning: Licensing: Temporary key will expire within 5 days; Alert: Licensing: Temporary key has expired; |
| 1.3.6.1.4.1.2505.1.3.5 | ScalarnatStatus | read-only | mandatory | Status of Network Address Translator. Possible Values: Disabled: NAT: NAT disabled; Warning: NAT: Reboot is required to start Interface NAT; Warning: NAT: NAT … |
| 1.3.6.1.4.1.2505.1.3.6 | ScalarantiSpoofingStatus | read-only | mandatory | Status of Anti Spoofing Feature. Possible Values: Disabled: Anti-Spoofing is Disabled; Warning: Anti-Spoofing : Packets Dropped; Alert: Anti-Spoofing state not… |
| 1.3.6.1.4.1.2505.1.3.7 | ScalarsslVpnStatus | read-only | mandatory | Status of SSL-VPN Accelerator. Possible Values: Disabled: Disabled Disabled: HW not installed Warning: Initialization in progress. Warning: Configuration Error… |
| 1.3.6.1.4.1.2505.1.3.8 | ScalarusrIpAddrStatus | read-only | mandatory | Status of User Ip Address Pool server. Possible Values: Alert : Alert : Alert : Alert : Warning : Healthy : Alert : Warning : Warning : Healthy : Healthy : Hea… |
| 1.3.6.1.4.1.2505.1.3.9 | ScalarvrrpStatus | read-only | mandatory | Status of VRRP Server. Possible Values: Disabled : Alert : Warning : Healthy : |
| 1.3.6.1.4.1.2505.1.3.10 | ScalarmcastRelayStatus | read-only | mandatory | Status of Multicast Relay. Possible Values: Warning : Disabled : Alert : Healthy : |
| 1.3.6.1.4.1.2505.1.3.11 | ScalardlswStatus | read-only | mandatory | Status of DLSW Server. Possible Values: Healthy : Disabled : Disabled : Disabled : |
| 1.3.6.1.4.1.2505.1.3.12 | ScalaripsecFailoverStatus | read-only | mandatory | Status of IPsec Failover service. Possible Values: Disabled : Healthy : Alert : |
| 1.3.6.1.4.1.2505.1.3.13 | ScalartunnelGuardStatus | read-only | mandatory | Status of TunnelGuard. Possible Values: Disabled : Healthy : Alert : Warning : |
| 1.3.6.1.4.1.2505.1.3.14 | ScalarripStatus | read-only | mandatory | Status of RIP Server. Possible Values: Warning : Disabled : Alert : Alert : Healthy : |
| 1.3.6.1.4.1.2505.1.3.15 | ScalarroutePolicyStatus | read-only | mandatory | Status of Route Policy. Possible Values: Disable : Alert : Alert : Alert : Healthy : |
| 1.3.6.1.4.1.2505.1.3.16 | ScalarcRoutesMStatus | read-only | mandatory | Status of Client Routes Marshaler. Possible Values: Alert : Warning : Disabled: Healthy : |
| 1.3.6.1.4.1.2505.1.3.17 | ScalarigmpStatus | read-only | mandatory | Status of IGMP Server. Possible Values: Disabled : Warning : Warning : Alert : Healthy : |
| 1.3.6.1.4.1.2505.1.3.5001 | NodenetBuffersTrap | Network buffer usage | ||
| 1.3.6.1.4.1.2505.1.3.5002 | NodefireWallTrap | Status of internal firewall | ||
| 1.3.6.1.4.1.2505.1.3.5003 | NodefipsStatusTrap | Status of FIPS | ||
| 1.3.6.1.4.1.2505.1.3.5004 | NodelicensingStatusTrap | Status temporary SW Licenses | ||
| 1.3.6.1.4.1.2505.1.3.5005 | NodenatStatusTrap | Status of Network Address Translator | ||
| 1.3.6.1.4.1.2505.1.3.5006 | NodeantiSpoofingStatusTrap | Status of Anti Spoofing Feature | ||
| 1.3.6.1.4.1.2505.1.3.5007 | NodesslVpnStatusTrap | Status of SSL-VPN Accelerator | ||
| 1.3.6.1.4.1.2505.1.3.5008 | NodeusrIpAddrStatusTrap | Status of User Ip Address Pool server | ||
| 1.3.6.1.4.1.2505.1.3.5009 | NodevrrpStatusTrap | Status of VRRP Server | ||
| 1.3.6.1.4.1.2505.1.3.50010 | NodemcastRelayStatusTrap | Status of Multicast Relay | ||
| 1.3.6.1.4.1.2505.1.3.50011 | NodedlswStatusTrap | Status of DLSW Server | ||
| 1.3.6.1.4.1.2505.1.3.50012 | NodeipsecFailoverStatusTrap | Status of IPsec Failover service | ||
| 1.3.6.1.4.1.2505.1.3.50013 | NodetunnelGuardStatusTrap | Status of TunnelGuard | ||
| 1.3.6.1.4.1.2505.1.3.50014 | NoderipStatusTrap | Status of RIP Server | ||
| 1.3.6.1.4.1.2505.1.3.50015 | NoderoutePolicyStatusTrap | Status of Route Policy | ||
| 1.3.6.1.4.1.2505.1.3.50016 | NodecRoutesMStatusTrap | Status of Client Routes Marshaler | ||
| 1.3.6.1.4.1.2505.1.3.50017 | NodeigmpStatusTrap | Status of IGMP Server | ||
| 1.3.6.1.4.1.2505.1.4 | NodeloginCESTrapInfo | |||
| 1.3.6.1.4.1.2505.1.4.1 | ScalarfailedLogin | read-only | mandatory | Failed Login Attempt. Possible Values: Failed Login Attempt: Username=IPSEC Encrypted: Date/Time=(xx) ; Failed Login Attempt: Username=(userid): Date/Time=(xx)… |
| 1.3.6.1.4.1.2505.1.4.101 | NodefailedLoginTrap | Failed Login Attempt | ||
| 1.3.6.1.4.1.2505.1.5 | NodeintrusionCESTrapInfo | |||
| 1.3.6.1.4.1.2505.1.5.1 | ScalarsecurityIntrusion | read-only | mandatory | Security Intrusion. Possible Values: Intruder: : Source: %s, Destination: %s; |
| 1.3.6.1.4.1.2505.1.5.201 | NodesecurityIntrusionTrap | Security Intrusion | ||
| 1.3.6.1.4.1.2505.1.6 | ScalarpowerUpTrap | read-only | deprecated | Power Up. Possible Values: Cold Start |
| 1.3.6.1.4.1.2505.1.7 | ScalarseverityLevel | read-only | mandatory | Severity of specific trap. |
| 1.3.6.1.4.1.2505.1.8 | ScalarsystemName | read-only | mandatory | System Name. |
| 1.3.6.1.4.1.2505.1.9 | ScalarsystemDate | read-only | mandatory | System Date. |
| 1.3.6.1.4.1.2505.1.10 | ScalarsystemTime | read-only | mandatory | System Time. |
| 1.3.6.1.4.1.2505.1.11 | ScalarsystemUpTime | read-only | mandatory | System Up Time. |
| 1.3.6.1.4.1.2505.1.12 | ScalarperiodicHeartbeat | read-only | mandatory | Periodic Heartbeat. Possible Values: Has been executed n times |
| 1.3.6.1.4.1.2505.1.14 | NodesnmpAgentTrapInfo-ces | |||
| 1.3.6.1.4.1.2505.1.14.1 | NodesnmpAgentAuthTrapInfo-ces | |||
| 1.3.6.1.4.1.2505.1.14.1.1 | ScalarsnmpAuthenOperation-ces | read-only | mandatory | SNMP operation attempted. |
| 1.3.6.1.4.1.2505.1.14.1.2 | ScalarsnmpAuthenIpAddress-ces | read-only | mandatory | IP address of host trying to access the CES. |
| 1.3.6.1.4.1.2505.1.14.1.3 | ScalarsnmpAuthenCommString-ces | read-only | mandatory | Community string used to access the CES. |
| 1.3.6.1.4.1.2505.1.14.2 | NodesnmpAgentInterfaceInfo-ces | |||
| 1.3.6.1.4.1.2505.1.14.2.1 | ScalarifReasonForStatus-ces | read-only | mandatory | The reason for the status change. These include: unknown(1) timed-out(2) |
| 1.3.6.1.4.1.2505.1.14.2.2 | ScalarifPhysLocation-ces | read-only | mandatory | The physical location of the port. This has the values of motherBoardOrSlot0, slot1, slot2, slot3, slot4, slot5. |
| 1.3.6.1.4.1.2505.1.14.2.3 | ScalarifPhysRelPos-ces | read-only | mandatory | The relative position of the physical port at the location defined by interfacePhysLocation. |
| 1.3.6.1.4.1.2505.1.14.2.4 | ScalarifIpAddr-ces | read-only | mandatory | For physical ports this is the associated IP address. For a tunnel connection it is the local IP address. |
| 1.3.6.1.4.1.2505.1.14.2.5 | ScalarifName-ces | read-only | mandatory | The name of the interface, same as ifName. |
| 1.3.6.1.4.1.2505.1.14.2.6 | ScalarifTunnelRemoteIpAddr-ces | read-only | mandatory | The remote IP address of a tunnel connection. |
| 1.3.6.1.4.1.2505.1.14.3 | NodesnmpAgentFirewallInfo-ces | |||
| 1.3.6.1.4.1.2505.1.14.3.1 | ScalarfirewallPolicyType-ces | read-only | mandatory | Policy type. |
| 1.3.6.1.4.1.2505.1.14.3.1 | NodefirewallRuleTriggeredTrap | An event sent at the user's request to signal that a rule has been matched. firewallPolicyType-ces firewallRuleType-ces firewallRuleNumber-ces ifIndex ifName-c… | ||
| 1.3.6.1.4.1.2505.1.14.3.2 | ScalarfirewallRuleType-ces | read-only | mandatory | Type of rule that triggered this event. |
| 1.3.6.1.4.1.2505.1.14.3.3 | ScalarfirewallRuleNumber-ces | read-only | mandatory | Number of the rule that triggered this event. |
| 1.3.6.1.4.1.2505.1.14.3.6 | ScalarfirewallSrcAddr-ces | read-only | mandatory | Source IP address of the packet. |
| 1.3.6.1.4.1.2505.1.14.3.7 | ScalarfirewallSrcPort-ces | read-only | mandatory | Source port address of the packet. |
| 1.3.6.1.4.1.2505.1.14.3.8 | ScalarfirewallDestAddr-ces | read-only | mandatory | Destination IP address of the packet. |
| 1.3.6.1.4.1.2505.1.14.3.9 | ScalarfirewallDestPort-ces | read-only | mandatory | Destination port of the packet. |
| 1.3.6.1.4.1.2505.1.14.3.10 | ScalarfirewallProtocolID-ces | read-only | mandatory | The value of the protocol field in the IP header. |
| 1.3.6.1.4.1.2505.1.14.3.11 | ScalarfirewallRuleAction-ces | read-only | mandatory | Action defined for the triggered rule. |
| 1.3.6.1.4.1.2505.1.401 | NodepowerUpTrapEntry | Power Up | ||
| 1.3.6.1.4.1.2505.1.601 | NodeperiodicHeartbeatTrap | Periodic Heartbeat |