CPQCR-MIB
128 objects
No module-level DESCRIPTION found.
Imported Objects
| CPQHOST-MIB | compaq cpqHoTrapFlags |
| RFC-1212 | OBJECT-TYPE |
| RFC-1215 | TRAP-TYPE |
| RFC1155-SMI | Counter enterprises Gauge |
| RFC1213-MIB | DisplayString sysName |
| OID | Name | Access | Status | Description |
|---|---|---|---|---|
| 1.3.6.1.4.1.232.141 | NodecpqClusteredRAID | |||
| 1.3.6.1.4.1.232.141.1 | NodecpqCrMibRev | |||
| 1.3.6.1.4.1.232.141.1.1 | ScalarcpqCrMibRevMajor | read-only | mandatory | The Major Revision level. A change in the major revision level represents a major change in the architecture of the MIB. A change in the major revision level m… |
| 1.3.6.1.4.1.232.141.1.2 | ScalarcpqCrMibRevMinor | read-only | mandatory | The Minor Revision level. A change in the minor revision level may represent some minor additional support, no changes to any pre-existing information has occu… |
| 1.3.6.1.4.1.232.141.1.3 | ScalarcpqCrMibCondition | read-only | mandatory | The overall condition (status) of the system represented by this MIB. |
| 1.3.6.1.4.1.232.141.2 | NodecpqCrComponent | |||
| 1.3.6.1.4.1.232.141.2.1 | NodecpqCrInterface | |||
| 1.3.6.1.4.1.232.141.2.1.4 | NodecpqCrOsCommon | |||
| 1.3.6.1.4.1.232.141.2.1.4.1 | ScalarcpqCrOsCommonPollFreq | read-write | mandatory | The Insight Agent's polling frequency. The frequency, in seconds, at which the Insight Agent requests information from the device driver. A frequency of zero (… |
| 1.3.6.1.4.1.232.141.2.2 | NodecpqCrCntlr | |||
| 1.3.6.1.4.1.232.141.2.2.1 | TablecpqCrCntlrTable | not-accessible | mandatory | Clustered RAID Array Controller Table. |
| 1.3.6.1.4.1.232.141.2.2.1.1 | RowcpqCrCntlrEntry | not-accessible | mandatory | Clustered RAID Array Controller Entry. |
| 1.3.6.1.4.1.232.141.2.2.1.1.1 | ColumncpqCrCntlrIndex | read-only | mandatory | Clustered RAID Array Controller Index. This value is a logical number whose meaning is OS dependent. Each physical controller has one unique controller number … |
| 1.3.6.1.4.1.232.141.2.2.1.1.2 | ColumncpqCrCntlrSerialNumber | read-only | mandatory | CR3500 Controller Serial Number. |
| 1.3.6.1.4.1.232.141.2.2.1.1.3 | ColumncpqCrCntlrFWRev | read-only | mandatory | Clustered RAID Array Controller Firmware Revision. The firmware revision of the Clustered RAID Controller. This value can be used to help identify a particular… |
| 1.3.6.1.4.1.232.141.2.2.1.1.4 | ColumncpqCrCntlrCondition | read-only | mandatory | The condition of the device. This value represents the overall condition of this controller, and any associated logical drives, physical drives, and array acce… |
| 1.3.6.1.4.1.232.141.2.2.1.1.8 | ColumncpqCrCntlrCurrentRole | read-only | mandatory | Clustered RAID Array Controller Current Role. For duplexed array controllers, this is the controllers current role. The following values are valid: other (1) I… |
| 1.3.6.1.4.1.232.141.2.2.1.1.9 | ColumncpqCrCntlrDriveOwnership | read-only | mandatory | Clustered RAID Array Controller Drive Ownership. For duplexed controllers, indicates to which controller slot the shared devices are associated. The following … |
| 1.3.6.1.4.1.232.141.2.2.1.1.10 | ColumncpqCrCntlrRebuildRate | read-only | mandatory | Clustered RAID Array Controller Rebuild Rate. Determines the rate at which disks are to be rebuilt if there is I/O activity. 1 = Minimum rate 100 = Maximum rate |
| 1.3.6.1.4.1.232.141.2.2.1.1.11 | ColumncpqCrCntlrCreateRate | read-only | mandatory | Clustered RAID Array Controller Create Rate. Determines the rate at which RAIDsets are to be created if there is I/O activity. 1 = Minimum rate 100 = maximum r… |
| 1.3.6.1.4.1.232.141.2.2.1.1.12 | ColumncpqCrCntlrCacheSize | read-only | mandatory | Clustered RAID Array Controller Cache Size. Size of the controller's cache in MB. |
| 1.3.6.1.4.1.232.141.2.2.1.1.13 | ColumncpqCrCntlrSimmSizeA | read-only | mandatory | Clustered RAID Array Controller Memory Module Size. Size of the memory module in slot A in MB. |
| 1.3.6.1.4.1.232.141.2.2.1.1.14 | ColumncpqCrCntlrSimmSizeB | read-only | mandatory | Clustered RAID Array Controller Memory Module Size. Size of the memory module in slot B in MB. |
| 1.3.6.1.4.1.232.141.2.3 | NodecpqCrLogDrv | |||
| 1.3.6.1.4.1.232.141.2.3.1 | TablecpqCrLogDrvTable | not-accessible | mandatory | Clustered RAID RAIDset Table. A table of RAIDset entries. |
| 1.3.6.1.4.1.232.141.2.3.1.1 | RowcpqCrLogDrvEntry | not-accessible | mandatory | Clustered RAID RAIDset Entry. A RAIDset entry. |
| 1.3.6.1.4.1.232.141.2.3.1.1.1 | ColumncpqCrLogDrvCntlrIndex | read-only | mandatory | Clustered RAID RAIDset Controller Index. This maps the RAIDsets into their respective controllers. Controller index 'i' under the controller group owns the ass… |
| 1.3.6.1.4.1.232.141.2.3.1.1.2 | ColumncpqCrLogDrvIndex | read-only | mandatory | Clustered RAID RAIDset Index. This logical drive number keeps track of multiple instances of logical drives which are on the same controller. For each controll… |
| 1.3.6.1.4.1.232.141.2.3.1.1.3 | ColumncpqCrLogDrvRAIDLevel | read-only | mandatory | RAID Level. This shows the RAID level of the RAIDset. To change the RAID level, run the CL1850 Array Configuration Utility. The following values are valid for … |
| 1.3.6.1.4.1.232.141.2.3.1.1.4 | ColumncpqCrLogDrvStatus | read-only | mandatory | RAIDset Status. The RAIDset can be in one of the following states: Good (2) Indicates that the RAIDset is fully operational. Reduced (3) Indicates that the RAI… |
| 1.3.6.1.4.1.232.141.2.3.1.1.5 | ColumncpqCrLogDrvRebuildPercentage | read-only | mandatory | RAIDset Rebuild Percentage Complete. After a failed physical drive has been replaced, the physical drive must have its data rebuilt. This value shows how far t… |
| 1.3.6.1.4.1.232.141.2.3.1.1.7 | ColumncpqCrLogDrvAvailSpares | read-only | mandatory | RAIDset Available Spares. This indicates if this RAIDset has one or more spares designated for it that are not currently in use by another drive. Each octet pr… |
| 1.3.6.1.4.1.232.141.2.3.1.1.8 | ColumncpqCrLogDrvSize | read-only | mandatory | RAIDset Size. This is the size of the RAIDset in megabytes. This value is calculated using the value 1,048,576 (2^20) as a megabyte. Drive manufacturers someti… |
| 1.3.6.1.4.1.232.141.2.3.1.1.9 | ColumncpqCrLogDrvPhyDrvIDs | read-only | mandatory | RAIDset Physical Drive IDs. This lists the physical drive IDs which are associated with this RAIDset. These are the same IDs which can be used as indices into … |
| 1.3.6.1.4.1.232.141.2.3.1.1.10 | ColumncpqCrLogDrvCondition | read-only | mandatory | RAIDset condition. This value represents the overall condition of this RAIDset and any associated physical drives. |
| 1.3.6.1.4.1.232.141.2.3.1.1.11 | ColumncpqCrLogDrvPartitionIDs | read-only | mandatory | RAIDset Logical Drive IDs. This lists the logical drive IDs which are associated with this RAIDset. These are the same IDs which can be used as indices into th… |
| 1.3.6.1.4.1.232.141.2.4 | NodecpqCrSpareDrv | |||
| 1.3.6.1.4.1.232.141.2.4.1 | TablecpqCrSpareTable | not-accessible | mandatory | Clustered RAID Spare Table. A table of spare entries. |
| 1.3.6.1.4.1.232.141.2.4.1.1 | RowcpqCrSpareEntry | not-accessible | mandatory | Clustered RAID Spare Entry. An entry in the spare table. |
| 1.3.6.1.4.1.232.141.2.4.1.1.1 | ColumncpqCrSpareCntlrIndex | read-only | mandatory | Spare Controller Index. This index maps the spare drive back to the controller to which it is attached. The value of this index is the same as the one used und… |
| 1.3.6.1.4.1.232.141.2.4.1.1.2 | ColumncpqCrSparePhyDrvIndex | read-only | mandatory | Physical Drive Index. This index maps the spare to the physical drive it represents. The value of this index is the same as the one used with the physical driv… |
| 1.3.6.1.4.1.232.141.2.4.1.1.3 | ColumncpqCrSpareStatus | read-only | mandatory | Spare Status. This shows the status of the on-line spare drive. The following values are valid for the spare status: Hot Spare(5) The drive attached to this ch… |
| 1.3.6.1.4.1.232.141.2.4.1.1.4 | ColumncpqCrSpareCondition | read-only | mandatory | Spare Drive condition. This value represents the overall condition of this spare drive and any associated physical drives. |
| 1.3.6.1.4.1.232.141.2.4.1.1.5 | ColumncpqCrSpareScsiID | read-only | mandatory | SCSI ID. This value represents the SCSI identifier of this spare drive. |
| 1.3.6.1.4.1.232.141.2.5 | NodecpqCrPhyDrv | |||
| 1.3.6.1.4.1.232.141.2.5.1 | TablecpqCrPhyDrvTable | not-accessible | mandatory | Clustered RAID Physical Drive Table. A table of physical drive entries. |
| 1.3.6.1.4.1.232.141.2.5.1.1 | RowcpqCrPhyDrvEntry | not-accessible | mandatory | Clustered RAID Physical Drive Entry. A physical drive entry. |
| 1.3.6.1.4.1.232.141.2.5.1.1.1 | ColumncpqCrPhyDrvCntlrIndex | read-only | mandatory | Clustered RAID Physical Drive Controller Index. This index maps the physical drive back to the controller to which it is attached. The value of this index is t… |
| 1.3.6.1.4.1.232.141.2.5.1.1.2 | ColumncpqCrPhyDrvIndex | read-only | mandatory | Clustered RAID Physical Drive Index. This index is used for selecting the physical drive table entry. This number, along with the cpqCrPhyDrvCntlrIndex uniquel… |
| 1.3.6.1.4.1.232.141.2.5.1.1.3 | ColumncpqCrPhyDrvVendor | read-only | mandatory | Physical Drive Vendor. This is the name of the manufacturer of the physical drive. This value is based upon the vendor name as returned by the SCSI inquiry com… |
| 1.3.6.1.4.1.232.141.2.5.1.1.4 | ColumncpqCrPhyDrvModel | read-only | mandatory | Physical Drive Model. This is a text description of the physical drive. The text that appears depends upon who manufactured the drive and the drive type. For e… |
| 1.3.6.1.4.1.232.141.2.5.1.1.5 | ColumncpqCrPhyDrvRevision | read-only | mandatory | Physical Drive Revision. This shows the physical drive revision number. |
| 1.3.6.1.4.1.232.141.2.5.1.1.6 | ColumncpqCrPhyDrvStatus | read-only | mandatory | Physical Drive Status. This shows the status of the physical drive. The following values are valid for the physical drive status: Offline (3) The drive attache… |
| 1.3.6.1.4.1.232.141.2.5.1.1.7 | ColumncpqCrPhyDrvSize | read-only | mandatory | Physical Drive Size in MB. This is the size of the physical drive in megabytes. This value is calculated using the value 1,048,576 (2^20) as a megabyte. Drive … |
| 1.3.6.1.4.1.232.141.2.5.1.1.8 | ColumncpqCrPhyDrvCondition | read-only | mandatory | Physical Drive condition. This value represents the overall condition of this physical drive. |
| 1.3.6.1.4.1.232.141.2.5.1.1.9 | ColumncpqCrPhyDrvScsiID | read-only | mandatory | SCSI ID. This value represents the SCSI identifier of this physical drive. |
| 1.3.6.1.4.1.232.141.2.7 | NodecpqCrEMU | |||
| 1.3.6.1.4.1.232.141.2.7.1 | ScalarcpqCrEMUBoardTemperatureStatus | read-only | deprecated | Environmental Monitoring Unit (EMU) Board Temperature status. The System Board Temperature status as determined by the EMU is: Not Installed (2) The board temp… |
| 1.3.6.1.4.1.232.141.2.7.2 | ScalarcpqCrEMUEnclosureTemperatureStatus | read-only | deprecated | Environmental Monitoring Unit (EMU) Enclosure Temperature status. The Enclosure Housing Temperature status as determined by the EMU is: Not Installed (2) The e… |
| 1.3.6.1.4.1.232.141.2.7.3 | ScalarcpqCrEMUBoardTemperatureLevel | read-only | deprecated | Environmental Monitoring Unit (EMU) Board Temperature. Indicates the System Board temperature in degrees Fahrenheit. |
| 1.3.6.1.4.1.232.141.2.7.4 | ScalarcpqCrEMUEnclosureTemperatureLevel | read-only | deprecated | Environmental Monitoring Unit (EMU) Enclosure Temperature. Indicates the Enclosure Housing temperature in degrees Fahrenheit. |
| 1.3.6.1.4.1.232.141.2.7.5 | ScalarcpqCrEMUCondition | read-only | mandatory | Primary enclosure condition. This value represents the overall condition of the primary enclosure. |
| 1.3.6.1.4.1.232.141.2.7.6 | ScalarcpqCrEMUFanStatus | read-only | mandatory | Primary enclosure fan status. The primary enclosure fan status is: OK (2) Status is normal. Critical (3) Fan has failed. Unknown (4) Information unavailable. |
| 1.3.6.1.4.1.232.141.2.7.7 | ScalarcpqCrEMUFanCondition | read-only | mandatory | Primary enclosure fan condition. This value represents the overall condition of the fan in the primary enclosure. |
| 1.3.6.1.4.1.232.141.2.7.8 | ScalarcpqCrEMUPowerSupplyStatus | read-only | mandatory | Primary enclosure power supply status. The primary enclosure power supply status is: OK (2) Status is normal. Critical (3) Power supply is installed and marked… |
| 1.3.6.1.4.1.232.141.2.7.9 | ScalarcpqCrEMUPowerSupplyCondition | read-only | mandatory | Primary enclosure power supply condition. This value represents the overall condition of the power supply in the primary enclosure. |
| 1.3.6.1.4.1.232.141.2.7.10 | ScalarcpqCrEMUTemperatureStatus | read-only | mandatory | Primary enclosure temperature status. The primary enclosure temperature status is: OK (2) Status is normal. Critical (3) Controller temperature sensor has dete… |
| 1.3.6.1.4.1.232.141.2.7.11 | ScalarcpqCrEMUTemperatureLevel | read-only | mandatory | Primary enclosure temperature. Indicates the temperature within the primary enclosure in degrees Celsius. |
| 1.3.6.1.4.1.232.141.2.7.12 | ScalarcpqCrEMUTemperatureCondition | read-only | mandatory | Primary enclosure temperature condition. This value represents the overall condition of the temperature in the primary enclosure. |
| 1.3.6.1.4.1.232.141.2.8 | NodecpqCrExpCab | |||
| 1.3.6.1.4.1.232.141.2.8.1 | ScalarcpqCrExpCabPowerSupplyStatus | read-only | mandatory | Expansion Cabinet power supply status. The expansion cabinet power supply status is: OK (2) Status is normal. Either redundant power supplies are installed and… |
| 1.3.6.1.4.1.232.141.2.8.2 | ScalarcpqCrExpCabFanStatus | read-only | mandatory | Expansion Cabinet fan status. The expansion cabinet fan status is: OK (2) Status is normal. One or more fans is installed and no error is reported. Non-Critica… |
| 1.3.6.1.4.1.232.141.2.8.3 | ScalarcpqCrExpCabTemperatureStatus | read-only | mandatory | Expansion Cabinet temperature status. The expansion cabinet temperature status is: OK (2) Status is normal. Critical (3) Critical temperature condition reporte… |
| 1.3.6.1.4.1.232.141.2.8.6 | ScalarcpqCrExpCabCondition | read-only | mandatory | Expansion Cabinet condition. This value represents the overall condition of the expansion cabinet. |
| 1.3.6.1.4.1.232.141.2.8.7 | ScalarcpqCrExpCabPowerSupplyCondition | read-only | mandatory | Expansion Cabinet power supply condition. This value represents the overall condition of the power supply in the expansion cabinet. |
| 1.3.6.1.4.1.232.141.2.8.9 | ScalarcpqCrExpCabFanCondition | read-only | mandatory | Expansion Cabinet fan condition. This value represents the overall condition of the fan in the expansion cabinet. |
| 1.3.6.1.4.1.232.141.2.8.10 | ScalarcpqCrExpCabTemperatureCondition | read-only | mandatory | Expansion Cabinet temperature condition. This value represents the overall condition of the temperature in the expansion cabinet. |
| 1.3.6.1.4.1.232.141.2.9 | NodecpqCrPartition | |||
| 1.3.6.1.4.1.232.141.2.9.1 | TablecpqCrPartitionTable | not-accessible | mandatory | Clustered RAID Logical Drive Table. A table of logical drive entries. |
| 1.3.6.1.4.1.232.141.2.9.1.1 | RowcpqCrPartitionEntry | not-accessible | mandatory | Clustered RAID Logical Drive Entry. A Logical Drive entry. |
| 1.3.6.1.4.1.232.141.2.9.1.1.1 | ColumncpqCrPartitionLogDrvIndex | read-only | mandatory | Clustered RAID Logical Drive Index. This maps the logical drives into their respective RAIDsets. RAIDset index 'i' under the RAIDset group owns the associated … |
| 1.3.6.1.4.1.232.141.2.9.1.1.2 | ColumncpqCrPartitionIndex | read-only | mandatory | Clustered RAID Logical Drive Index. This logical drive number keeps track of multiple instances of logical drives which are part of the same RAIDset. For each … |
| 1.3.6.1.4.1.232.141.2.9.1.1.3 | ColumncpqCrPartitionRAIDLevel | read-only | mandatory | Logical Drive RAID Level. This shows the RAID level of the logical drive. To change the RAID level, run the CR3500 Array Configuration Utility. The following v… |
| 1.3.6.1.4.1.232.141.2.9.1.1.4 | ColumncpqCrPartitionStatus | read-only | mandatory | Logical Drive Status. The logical drive can be in one of the following states: Good (2) Indicates that the logical drive is fully operational. Reduced (3) Indi… |
| 1.3.6.1.4.1.232.141.2.9.1.1.5 | ColumncpqCrPartitionSize | read-only | mandatory | Logical Drive Size. This is the size of the logical drive in megabytes. This value is calculated using the value 1,048,576 (2^20) as a megabyte. Drive manufact… |
| 1.3.6.1.4.1.232.141.2.9.1.1.6 | ColumncpqCrPartitionCondition | read-only | mandatory | Logical drive condition. This value represents the overall condition of this logical drive and any associated physical drives. |
| 1.3.6.1.4.1.232.141.3 | NodecpqCrTrap | |||
| 1.3.6.1.4.1.232.141.3.1 | NodecpqCrInterfaceTrap | |||
| 1.3.6.1.4.1.232.141.3.2 | NodecpqCrCntlrTrap | |||
| 1.3.6.1.4.1.232.141.3.2.1 | NodecpqCrController1FailureTrap | The primary controller in the subsytem has failed. Details: The primary Controller has failed. User Action: Replace controller. Possible causes are controller … | ||
| 1.3.6.1.4.1.232.141.3.2.2 | NodecpqCrController1InformationTrap | The primary controller in the subsytem has recovered. Details: The primary controller has recovered. User Action: None. | ||
| 1.3.6.1.4.1.232.141.3.2.3 | NodecpqCrController2FailureTrap | The secondary controller in the subsytem has failed. Details: The secondary controller has failed. User Action: Replace controller. Possible causes are control… | ||
| 1.3.6.1.4.1.232.141.3.2.4 | NodecpqCrController2InformationTrap | The secondary controller in the subsytem has recovered. Details: The secondary controller has recovered. User Action: None. | ||
| 1.3.6.1.4.1.232.141.3.3 | NodecpqCrLogDrvTrap | |||
| 1.3.6.1.4.1.232.141.3.3.5 | NodecpqCrLogDriveInformationTrap | A RAIDset has become optimal. Details: A RAIDset has become optimal due to a successful completion of the reconstruction process. User Action: None. | ||
| 1.3.6.1.4.1.232.141.3.3.6 | NodecpqCrLogDriveFailureTrap | A RAIDset has failed. Details: The RAIDset has failed and is off-line. User Action: Possible cause is too many failed disk drives that make up the RAIDset, the… | ||
| 1.3.6.1.4.1.232.141.3.3.7 | NodecpqCrLogDriveReconstructTrap | A RAIDset has started the reconstruction process. Details: The RAIDset has started the reconstruction process but is available for normal use. Possible causes … | ||
| 1.3.6.1.4.1.232.141.3.3.8 | NodecpqCrLogDriveReducedTrap | A RAIDset has become degraded. Details: A RAIDset has become degraded due to a member disk device failure. User Action: Replace the failed disk device; add a s… | ||
| 1.3.6.1.4.1.232.141.3.3.9 | NodecpqCrLogDriveInitializingTrap | A RAIDset is initializing. Details: A RAIDset is in the process of being intialized. User Action: None. | ||
| 1.3.6.1.4.1.232.141.3.4 | NodecpqCrSpareDrvTrap | |||
| 1.3.6.1.4.1.232.141.3.5 | NodecpqCrPhyDrvTrap | |||
| 1.3.6.1.4.1.232.141.3.5.10 | NodecpqCrDiskInformationTrap | A disk drive has recovered. Details: A disk device has recovered. User Action: None. | ||
| 1.3.6.1.4.1.232.141.3.5.11 | NodecpqCrDiskFailureTrap | A disk drive has failed. Details: A disk device has failed. User Action: Replace the disk device. | ||
| 1.3.6.1.4.1.232.141.3.5.12 | NodecpqCrDiskReconstructTrap | A disk drive has started the reconstruction process. Details: A disk member of a logical drive has begun the reconstruction process and will be available for u… | ||
| 1.3.6.1.4.1.232.141.3.5.13 | NodecpqCrDiskAvailableTrap | A disk drive has been made available for use. Details: A disk drive has been physically added or set to the Available state. It can be used as a RAIDset member… | ||
| 1.3.6.1.4.1.232.141.3.5.14 | NodecpqCrDiskSpareTrap | A disk drive has been made a Spare. Details: A disk drive has been set to Spare status from Available and may be used in a RAID 1, RAID 0+1 or RAID 5 logical d… | ||
| 1.3.6.1.4.1.232.141.3.5.30 | NodecpqCrPhyDiskInformationTrap | A disk drive has recovered. Details: A disk device has recovered. User Action: None. | ||
| 1.3.6.1.4.1.232.141.3.5.31 | NodecpqCrPhyDiskFailureTrap | A disk drive has failed. Details: A disk device has failed. User Action: Replace the disk device. | ||
| 1.3.6.1.4.1.232.141.3.5.32 | NodecpqCrPhyDiskReconstructTrap | A disk drive has started the reconstruction process. Details: A disk member of a logical drive has begun the reconstruction process and will be available for u… | ||
| 1.3.6.1.4.1.232.141.3.5.33 | NodecpqCrPhyDiskAvailableTrap | A disk drive has been made available for use. Details: A disk drive has been physically added or set to the Available state. It can be used as a RAIDset member… | ||
| 1.3.6.1.4.1.232.141.3.5.34 | NodecpqCrPhyDiskSpareTrap | A disk drive has been made a Spare. Details: A disk drive has been set to Spare status from Available and may be used in a RAID 1, RAID 0+1 or RAID 5 logical d… | ||
| 1.3.6.1.4.1.232.141.3.7 | NodecpqCrEMUTrap | |||
| 1.3.6.1.4.1.232.141.3.7.15 | NodecpqCrEMUNormalTrap | Primary enclosure state is normal. Details: The overall condition of the primary enclosure has returned to normal. User Action: None. | ||
| 1.3.6.1.4.1.232.141.3.7.16 | NodecpqCrEMUFanFailureTrap | Fan has failed. Details: One of the cooling fans in the primary enclosure has failed. User Action: Replace the cooling fan. Possible causes are fan physically … | ||
| 1.3.6.1.4.1.232.141.3.7.17 | NodecpqCrEMUFanInformationTrap | The fan has recovered. Details: The cooling fan in the primary enclosure has recovered. User Action: None. | ||
| 1.3.6.1.4.1.232.141.3.7.18 | NodecpqCrEMUPowerSupplyFailureTrap | Power supply has failed. Details: One of the power supplies in the primary enclosure has failed. User Action: Replace the power supply. Possible causes are pow… | ||
| 1.3.6.1.4.1.232.141.3.7.19 | NodecpqCrEMUPowerSupplyInformationTrap | The power supply has recovered. Details: The power supply in the primary enclosure has recovered. User Action: None. | ||
| 1.3.6.1.4.1.232.141.3.7.23 | NodecpqCrEMUTemperatureWarningTrap | Primary enclosure temperature warning. Details: The temperature in the primary enclosure has triggered a warning condition detected by the controller. User Act… | ||
| 1.3.6.1.4.1.232.141.3.7.24 | NodecpqCrEMUTemperatureCriticalTrap | Primary enclosure temperature critical!. Details: The temperature in the primary enclosure has triggered a critical condition detected by the controller. User … | ||
| 1.3.6.1.4.1.232.141.3.7.25 | NodecpqCrEMUTemperatureInformationTrap | Primary enclosure temperature normal. Details: The temperature in the primary enclosure has returned to normal. User Action: None. | ||
| 1.3.6.1.4.1.232.141.3.8 | NodecpqCrExpCabTrap | |||
| 1.3.6.1.4.1.232.141.3.8.20 | NodecpqCrExpCabFanFailureTrap | Fan has failed in expansion cabinet. Details: One of the cooling fans in the expansion cabinet has failed. User Action: Replace the cooling fan. Possible cause… | ||
| 1.3.6.1.4.1.232.141.3.8.21 | NodecpqCrExpCabFanInformationTrap | Fan has recovered. Details: A cooling fan in the expansion cabinet has returned to a normal state. User Action: None. | ||
| 1.3.6.1.4.1.232.141.3.8.22 | NodecpqCrExpCabPowerSupplyFailureTrap | Power supply has failed. Details: One of the power supplies in the expansion cabinet has failed. User Action: Replace the power supply. Possible causes are pow… | ||
| 1.3.6.1.4.1.232.141.3.8.26 | NodecpqCrExpCabTemperatureWarningTrap | Expansion cabinet temperature warning. Details: The temperature in the expansion cabinet has triggered a warning condition detected by the controller. User Act… | ||
| 1.3.6.1.4.1.232.141.3.8.27 | NodecpqCrExpCabTemperatureCriticalTrap | Expansion cabinet temperature critical! Details: The temperature in the expansion cabinet has triggered a critical condition detected by the controller. User A… | ||
| 1.3.6.1.4.1.232.141.3.8.28 | NodecpqCrExpCabTemperatureInformationTrap | Expansion cabinet temperature normal. Details: The temperature in the expansion cabinet has returned to normal. User Action: None. | ||
| 1.3.6.1.4.1.232.141.3.8.29 | NodecpqCrExpCabPowerSupplyInformationTrap | The power supply has recovered. Details: The power supply in the expansion cabinet has recovered. User Action: None. |