MIB Viewer

CPQIDA-MIB

513 objects
No module-level DESCRIPTION found.
Imported Objects
CPQHOST-MIBcompaq cpqHoTrapFlags
RFC-1212OBJECT-TYPE
RFC-1215TRAP-TYPE
RFC1155-SMI-- enterprises Counter Gauge
RFC1213-MIBDisplayString sysName
OIDNameAccessStatusDescription
1.3.6.1.4.1.232.3NodecpqDriveArray
1.3.6.1.4.1.232.3.1NodecpqDaLogDrvStatusChangeLogical Drive Status Change. This trap signifies that the agent has detected a change in the status of a drive array logical drive. The variable cpqDaLogDrvSta…
1.3.6.1.4.1.232.3.1NodecpqDaMibRev
1.3.6.1.4.1.232.3.1.1ScalarcpqDaMibRevMajorread-onlymandatoryThe Major Revision level. A change in the major revision level represents a major change in the architecture of the MIB. A change in the major revision level m…
1.3.6.1.4.1.232.3.1.2ScalarcpqDaMibRevMinorread-onlymandatoryThe Minor Revision level. A change in the minor revision level may represent some minor additional support, no changes to any pre-existing information has occu…
1.3.6.1.4.1.232.3.1.3ScalarcpqDaMibConditionread-onlymandatoryThe overall condition (status) of the system represented by this MIB.
1.3.6.1.4.1.232.3.2NodecpqDaComponent
1.3.6.1.4.1.232.3.2NodecpqDaSpareStatusChangeSpare Drive Status Change. This trap signifies that the agent has detected a change in the status of a drive array spare drive. The variable cpqDaSpareStatus i…
1.3.6.1.4.1.232.3.2.1NodecpqDaInterface
1.3.6.1.4.1.232.3.2.1.1NodecpqDaOsNetWare3x
1.3.6.1.4.1.232.3.2.1.1.1ScalarcpqDaNw3xDriverNameread-onlydeprecatedArray Controller Driver Interface Name. This is the name of the device driver for the Array Controllers.
1.3.6.1.4.1.232.3.2.1.1.2ScalarcpqDaNw3xDriverVerread-onlydeprecatedArray Controller Driver Interface Version. This is the version number of the device driver for the Array Controllers.
1.3.6.1.4.1.232.3.2.1.1.3ScalarcpqDaNw3xPollTyperead-onlydeprecatedArray Controller Driver Interface Poll Type. The Insight Agent collects information from the device driver in two ways: Polled (2) Indicates that the informati…
1.3.6.1.4.1.232.3.2.1.1.4ScalarcpqDaNw3xPollTimeread-onlydeprecatedArray Controller Driver Interface Poll Time. If the Poll Type is Polled, this value shows how frequently, in seconds, the instrument agent requests Information…
1.3.6.1.4.1.232.3.2.1.1.5TablecpqDaNw3xDriverStatTablenot-accessibledeprecatedArray Controller Driver Statistics Table. This is a table of logical drive statistics which are gathered by the device driver.
1.3.6.1.4.1.232.3.2.1.1.5.1RowcpqDaNw3xDriverStatEntrynot-accessibledeprecatedArray Controller Driver Statistics Table Entry. One entry in the driver statistics table. Each entry represents a logical drive for which the statistics are ke…
1.3.6.1.4.1.232.3.2.1.1.5.1.1ColumncpqDaNw3xCntlrIndexread-onlydeprecatedArray Controller Index. This maps the logical drives into their respective controllers. This controller index matches the controller group entries.
1.3.6.1.4.1.232.3.2.1.1.5.1.2ColumncpqDaNw3xLogDrvIndexread-onlydeprecatedArray Logical Drive Index. This is the logical drive number which keeps track of multiple instances of logical drives which are on the same controller. For eac…
1.3.6.1.4.1.232.3.2.1.1.5.1.3ColumncpqDaNw3xTotalReadsread-onlydeprecatedArray Logical Drive Total Reads. This shows the total number of reads performed by the IDA device driver to this logical drive. This number is reset each time …
1.3.6.1.4.1.232.3.2.1.1.5.1.4ColumncpqDaNw3xTotalWritesread-onlydeprecatedArray Logical Drive Total Writes. This shows the total number of writes performed by the IDA device driver to this logical drive. This number is reset each tim…
1.3.6.1.4.1.232.3.2.1.1.5.1.5ColumncpqDaNw3xCorrReadsread-onlydeprecatedArray Logical Drive Corrected Reads. This is the total number of read commands sent to the specified logical drive which had to be corrected by fault tolerance…
1.3.6.1.4.1.232.3.2.1.1.5.1.6ColumncpqDaNw3xCorrWritesread-onlydeprecatedArray Logical Drive Corrected Writes. This is the total number of write commands sent to the specified logical drive which had to be corrected by fault toleran…
1.3.6.1.4.1.232.3.2.1.1.5.1.7ColumncpqDaNw3xFatalReadsread-onlydeprecatedArray Logical Drive Fatal Reads. This is the total number of read commands sent to the specified logical drive which failed. This number is reset each time the…
1.3.6.1.4.1.232.3.2.1.1.5.1.8ColumncpqDaNw3xFatalWritesread-onlydeprecatedArray Logical Drive Fatal Writes. This is the total number of write commands sent to the specified logical drive which failed. This number is reset each time t…
1.3.6.1.4.1.232.3.2.1.1.6TablecpqDaNw3xVolMapTablenot-accessibledeprecatedVolume Map Table. This is a table of NetWare volumes which map into the logical drives
1.3.6.1.4.1.232.3.2.1.1.6.1RowcpqDaNw3xVolMapEntrynot-accessibledeprecatedVolume Map Table Entry. One entry in the volume map table. Each entry represents a logical drive for which the volume map is kept.
1.3.6.1.4.1.232.3.2.1.1.6.1.1ColumncpqDaNw3xVolCntlrIndexread-onlydeprecatedArray Controller Index. This maps the logical drives into their respective controllers. This controller index matches the controller group entries.
1.3.6.1.4.1.232.3.2.1.1.6.1.2ColumncpqDaNw3xVolLogDrvIndexread-onlydeprecatedArray Logical Drive Index. This is the logical drive number which keeps track of multiple instances of logical drives which are on the same controller. For eac…
1.3.6.1.4.1.232.3.2.1.1.6.1.3ColumncpqDaNw3xVolMapread-onlydeprecatedNetWare Volume Map. This is a data structure containing the volume mappings for this logical drive. There are 8 entries in a volume mapping. Each entry has the…
1.3.6.1.4.1.232.3.2.1.4NodecpqDaOsCommon
1.3.6.1.4.1.232.3.2.1.4.1ScalarcpqDaOsCommonPollFreqread-writemandatoryThe Insight Agent`s polling frequency. The frequency, in seconds, at which the Insight Agent requests information from the device driver. A frequency of zero (…
1.3.6.1.4.1.232.3.2.1.4.2TablecpqDaOsCommonModuleTablenot-accessibledeprecatedA table of software modules that provide an interface to the device this MIB describes.
1.3.6.1.4.1.232.3.2.1.4.2.1RowcpqDaOsCommonModuleEntrynot-accessibledeprecatedA description of a software module that provides an interface to the device this MIB describes.
1.3.6.1.4.1.232.3.2.1.4.2.1.1ColumncpqDaOsCommonModuleIndexread-onlydeprecatedA unique index for this module description.
1.3.6.1.4.1.232.3.2.1.4.2.1.2ColumncpqDaOsCommonModuleNameread-onlydeprecatedThe module name.
1.3.6.1.4.1.232.3.2.1.4.2.1.3ColumncpqDaOsCommonModuleVersionread-onlydeprecatedThe module version in XX.YY format. Where XX is the major version number and YY is the minor version number. This field will be a null (size 0) string if the a…
1.3.6.1.4.1.232.3.2.1.4.2.1.4ColumncpqDaOsCommonModuleDateread-onlydeprecatedThe module date. field octets contents range ===== ====== ======= ===== 1 1-2 year 0..65536 2 3 month 1..12 3 4 day 1..31 4 5 hour 0..23 5 6 minute 0..59 6 7 s…
1.3.6.1.4.1.232.3.2.1.4.2.1.5ColumncpqDaOsCommonModulePurposeread-onlydeprecatedThe purpose of the module described in this entry.
1.3.6.1.4.1.232.3.2.1.4.3ScalarcpqDaOsCommonCollectionResetread-writeoptionalDrive Array MIB Collection Reset. This variable is used to force the collection agent for this MIB to scan the associated hardware for configuration changes. T…
1.3.6.1.4.1.232.3.2.2NodecpqDaCntlr
1.3.6.1.4.1.232.3.2.2.1TablecpqDaCntlrTablenot-accessiblemandatoryArray Controller Table.
1.3.6.1.4.1.232.3.2.2.1.1RowcpqDaCntlrEntrynot-accessiblemandatoryArray Controller Entry.
1.3.6.1.4.1.232.3.2.2.1.1.1ColumncpqDaCntlrIndexread-onlymandatoryArray Controller Index. This value is a logical number whose meaning is OS dependent. Each physical controller has one unique controller number associated with…
1.3.6.1.4.1.232.3.2.2.1.1.2ColumncpqDaCntlrModelread-onlymandatoryArray Controller Model. The type of controller card. The valid types are: Other (1) You may need to upgrade your driver software and\or instrument agent(s). Yo…
1.3.6.1.4.1.232.3.2.2.1.1.3ColumncpqDaCntlrFWRevread-onlymandatoryArray Controller Firmware Revision. The firmware revision of the drive array controller. This value can be used to help identify a particular revision of the c…
1.3.6.1.4.1.232.3.2.2.1.1.4ColumncpqDaCntlrStndIntrread-onlymandatoryThe status of the Standard Interface. The Standard Interface is how DOS communicates with a drive. The following values are valid for Standard Interface: Other…
1.3.6.1.4.1.232.3.2.2.1.1.5ColumncpqDaCntlrSlotread-onlymandatoryArray Controller Slot. This identifies the physical slot where the array controller resides in the system. For example, if this value is three, the array contr…
1.3.6.1.4.1.232.3.2.2.1.1.6ColumncpqDaCntlrConditionread-onlymandatoryThe condition of the device. This value represents the overall condition of this controller, and any associated logical drives, physical drives, and cache modu…
1.3.6.1.4.1.232.3.2.2.1.1.7ColumncpqDaCntlrProductRevread-onlymandatoryArray Controller Product Revision. The Product Revision of the drive array controller. This value can be used to further identify a particular revision of the …
1.3.6.1.4.1.232.3.2.2.1.1.8ColumncpqDaCntlrPartnerSlotread-onlymandatoryArray Controller Partner Slot. For duplexed array controllers, this is the slot number of the partner controller. For non-duplexed controllers and partner cont…
1.3.6.1.4.1.232.3.2.2.1.1.9ColumncpqDaCntlrCurrentRoleread-onlymandatoryArray Controller Current Role. For duplexed array controllers, this is the controllers current role. The following values are valid: other (1) Indicates that t…
1.3.6.1.4.1.232.3.2.2.1.1.10ColumncpqDaCntlrBoardStatusread-onlymandatoryArray Controller Board Status. The following values are valid: other (1) Indicates that the instrument agent does not recognize the status of the controller. Y…
1.3.6.1.4.1.232.3.2.2.1.1.11ColumncpqDaCntlrPartnerBoardStatusread-onlymandatoryArray Controller Partner Board Status. The following values are valid: other (1) Indicates that the instrument agent does not recognize the status of the contr…
1.3.6.1.4.1.232.3.2.2.1.1.12ColumncpqDaCntlrBoardConditionread-onlymandatoryThe condition of the device. This value represents the condition of the controller and any associated cache modules.
1.3.6.1.4.1.232.3.2.2.1.1.13ColumncpqDaCntlrPartnerBoardConditionread-onlymandatoryThe condition of the device. This value represents the condition of the controller and any associated cache modules.
1.3.6.1.4.1.232.3.2.2.1.1.14ColumncpqDaCntlrDriveOwnershipread-onlymandatoryArray Controller Drive Ownership. For duplexed controllers, indicates to which controller slot the shared devices are associated. The following values are vali…
1.3.6.1.4.1.232.3.2.2.1.1.15ColumncpqDaCntlrSerialNumberread-onlymandatoryArray Controller Serial Number. The serial number of the array controller. This field will be a null (size 0) string if the controller does not support serial …
1.3.6.1.4.1.232.3.2.2.1.1.16ColumncpqDaCntlrRedundancyTyperead-onlymandatoryArray Controller Redundancy Type. The following values are valid: other (1) Indicates that the instrument agent does not recognize the redundancy type of the c…
1.3.6.1.4.1.232.3.2.2.1.1.17ColumncpqDaCntlrRedundancyErrorread-onlymandatoryArray Controller Redundancy Error. The following values are valid: other (1) Indicates that the instrument agent does not recognize the redundancy error of the…
1.3.6.1.4.1.232.3.2.2.1.1.18ColumncpqDaCntlrAccessModuleStatusread-onlymandatoryArray Controller RAID ADG Enabler Module Status. The following values are valid: other (1) Indicates that the agent does not recognize the RAID ADG Enabler Mod…
1.3.6.1.4.1.232.3.2.2.1.1.19ColumncpqDaCntlrDaughterBoardTyperead-onlymandatoryArray Controller Daughter Board Type. The following values are valid: other (1) Indicates that the agent does not recognize the daughter board type. You may ne…
1.3.6.1.4.1.232.3.2.2.1.1.20ColumncpqDaCntlrHwLocationread-onlymandatoryA text description of the hardware location of the controller. A NULL string indicates that the hardware location could not be determined or is irrelevant.
1.3.6.1.4.1.232.3.2.2.1.1.21ColumncpqDaCntlrNumberOfBusesread-onlymandatoryArray Controller Number of Buses. This value is the number of SCSI buses on the controller.
1.3.6.1.4.1.232.3.2.2.1.1.22ColumncpqDaCntlrBlinkTimeread-writemandatoryController Physical Drive Blink Time Count. The controller blink time variable allows the drive tray LEDs of all physical drives attached to this controller to…
1.3.6.1.4.1.232.3.2.2.1.1.23ColumncpqDaCntlrRebuildPriorityread-onlymandatoryArray Controller Rebuild Priority. This is the controller`s rebuild priority. The following values are valid: other (1) Indicates that the instrument agent doe…
1.3.6.1.4.1.232.3.2.2.1.1.24ColumncpqDaCntlrExpandPriorityread-onlymandatoryArray Controller Expand Priority. This is the controller`s expand priority. The following values are valid: other (1) Indicates that the instrument agent does …
1.3.6.1.4.1.232.3.2.2.1.1.25ColumncpqDaCntlrNumberOfInternalPortsread-onlymandatoryArray Controller Number of Internal Ports. This value is the number of internal connectors on the controller.
1.3.6.1.4.1.232.3.2.2.1.1.26ColumncpqDaCntlrNumberOfExternalPortsread-onlymandatoryArray Controller Number of External Ports. This value is the number of external connectors on the controller.
1.3.6.1.4.1.232.3.2.2.1.1.27ColumncpqDaCntlrDriveWriteCacheStateread-onlymandatoryArray Controller Drive Write Cache State. This is the controller`s drive write cache setting. The following values are valid: other (1) Indicates that the inst…
1.3.6.1.4.1.232.3.2.2.1.1.28ColumncpqDaCntlrPartnerSerialNumberread-onlymandatoryArray Controller Partner Serial Number. The serial number of the partner array controller. This field will be a null (size 0) string if the partner controller …
1.3.6.1.4.1.232.3.2.2.1.1.29ColumncpqDaCntlrOptionRomRevread-onlymandatoryArray Controller Option ROM Revision. The option ROM revision of the chipset or HBA being used by the B-Series controller. If the controller does not support t…
1.3.6.1.4.1.232.3.2.2.1.1.30ColumncpqDaCntlrHbaFWRevread-onlymandatoryArray Controller HBA Firmware Revision. The firmware revision of the chipset or HBA being used by the B-Series controller. If the controller does not support t…
1.3.6.1.4.1.232.3.2.2.1.1.31ColumncpqDaCntlrHBAModeOptionRomRevread-onlymandatoryArray Controller HBA Mode Option Rom Revision. The revision of option ROM that would run on this chipset or HBA (being used by the B-Series controller), if it …
1.3.6.1.4.1.232.3.2.2.1.1.32ColumncpqDaCntlrCurrentTempread-onlymandatoryArray Controller Current Temperature. This is the temperature of the array controller in degrees Celsius. The field will contain -1 if the controller temperatu…
1.3.6.1.4.1.232.3.2.2.1.1.33ColumncpqDaCntlrLastLockupCoderead-onlymandatoryArray Controller Last Lockup Code. The lockup code of the array controller if a lockup occurred prior to the last controller reset. This value will be nonzero …
1.3.6.1.4.1.232.3.2.2.1.1.34ColumncpqDaCntlrEncryptionStatusread-onlymandatoryArray Controller Encryption Status. The following values are valid: other (1) Indicates that the instrument agent does not recognize the value. You may need to…
1.3.6.1.4.1.232.3.2.2.1.1.35ColumncpqDaCntlrASICEncptSelfTestStatusread-onlymandatoryArray Controller ASIC Encryption Self Test Status. The following values are valid: other (1) Indicates that the instrument agent does not recognize the value. …
1.3.6.1.4.1.232.3.2.2.1.1.36ColumncpqDaCntlrEncryptCspNvramStatusread-onlymandatoryArray Controller Encryption Critical Security Parameter NVRAM Status. The following values are valid: other (1) Indicates that the instrument agent does not re…
1.3.6.1.4.1.232.3.2.2.1.1.37ColumncpqDaCntlrEncryptCryptoOfficerPwdSetStatusread-onlymandatoryArray Controller Encryption Crypto Officer Password Set Status. The following values are valid: other (1) Indicates that the instrument agent does not recogniz…
1.3.6.1.4.1.232.3.2.2.1.1.38ColumncpqDaCntlrEncryptCntlrPwdSetStatusread-onlymandatoryArray Controller Encryption Controller Password Set Status. The following values are valid: other (1) Indicates that the instrument agent does not recognize th…
1.3.6.1.4.1.232.3.2.2.1.1.39ColumncpqDaCntlrEncryptCntlrPwdAvailStatusread-onlymandatoryArray Controller Encryption Controller Password Availability Status. The following values are valid: other (1) Indicates that the instrument agent does not rec…
1.3.6.1.4.1.232.3.2.2.1.1.40ColumncpqDaCntlrUnencryptedLogDrvCreationPolicyread-onlymandatoryArray Controller Unencrypted Logical Drive Creation Policy. The following values are valid: other (1) Indicates that the instrument agent does not recognize th…
1.3.6.1.4.1.232.3.2.2.1.1.41ColumncpqDaCntlrEncryptedLogDrvCreationPolicyread-onlymandatoryArray Controller Encrypted Logical Drive Creation Policy. The following values are valid: other (1) Indicates that the instrument agent does not recognize the …
1.3.6.1.4.1.232.3.2.2.1.1.42ColumncpqDaCntlrEncryptFWLockStatusread-onlymandatoryArray Controller Encryption Firmware Lock Status. The following values are valid: other (1) Indicates that the instrument agent does not recognize the value. Y…
1.3.6.1.4.1.232.3.2.2.1.1.43ColumncpqDaCntlrOperatingModeread-onlymandatoryArray Controller Operating Mode. The array controller`s current operating mode. The following values are valid: The following values are valid: other (1) Indic…
1.3.6.1.4.1.232.3.2.2.2TablecpqDaAccelTablenot-accessiblemandatoryCache Module Board Table. Note that for some controller models, a cache module board that physically attaches to the controller or chipset may not be an availa…
1.3.6.1.4.1.232.3.2.2.2.1RowcpqDaAccelEntrynot-accessiblemandatoryCache Module Board Entry.
1.3.6.1.4.1.232.3.2.2.2.1.1ColumncpqDaAccelCntlrIndexread-onlymandatoryCache Module Board Controller Index. This value is a logical number whose meaning is OS dependent. The value has a direct mapping to the controller table index…
1.3.6.1.4.1.232.3.2.2.2.1.2ColumncpqDaAccelStatusread-onlymandatoryCache Module/Operations Status. This describes the status of the cache module and/or cache operations. Note that for some controller models, a cache module boa…
1.3.6.1.4.1.232.3.2.2.2.1.3ColumncpqDaAccelMemoryread-onlymandatoryWrite Cache Memory. This shows the amount of memory allocated for the write cache in kilobytes. Because data is kept in duplicate (mirrored), the actual amount…
1.3.6.1.4.1.232.3.2.2.2.1.4ColumncpqDaAccelBadDataread-onlymandatoryCache Module Board Bad Data. The following values are valid: None (2) Indicates that no data loss occurred. The battery packs were properly charged when the sy…
1.3.6.1.4.1.232.3.2.2.2.1.5ColumncpqDaAccelErrCoderead-onlymandatoryCache Module Board Error Code. Use this to determine the status of the write cache operations. The status can be: Other (1) Indicates that the instrument agent…
1.3.6.1.4.1.232.3.2.2.2.1.6ColumncpqDaAccelBatteryread-onlymandatoryCache Module Board Backup Power Status. This monitors the status of each backup power source on the board. The backup power source can only recharge when the s…
1.3.6.1.4.1.232.3.2.2.2.1.7ColumncpqDaAccelReadErrsread-onlymandatoryCache Module Board Read Errors. This shows the total number of read memory parity errors that were detected while reading from the Cache Module board. The mirr…
1.3.6.1.4.1.232.3.2.2.2.1.8ColumncpqDaAccelWriteErrsread-onlymandatoryCache Module Board Write Errors. This shows the total number of write memory parity errors that were detected while writing to the Cache Module board. Write pa…
1.3.6.1.4.1.232.3.2.2.2.1.9ColumncpqDaAccelConditionread-onlymandatoryThe condition of the device. This value represents the overall condition of this cache module.
1.3.6.1.4.1.232.3.2.2.2.1.10ColumncpqDaAccelReadMemoryread-onlymandatoryRead Cache Memory. This shows the amount of memory allocated for the read cache in kilobytes. Because data is kept in duplicate (mirrored), the actual amount o…
1.3.6.1.4.1.232.3.2.2.2.1.11ColumncpqDaAccelSerialNumberread-onlymandatoryCache Module Serial Number. The serial number of the Cache Module. This field will be a null (size 0) string if the cache module does not support serial number.
1.3.6.1.4.1.232.3.2.2.2.1.12ColumncpqDaAccelTotalMemoryread-onlymandatoryTotal Cache Memory. This value is the total amount of cache module memory in kilobytes, including both battery-backed and non-battery-backed memory.
1.3.6.1.4.1.232.3.2.2.2.1.13ColumncpqDaAccelReadCachePercentread-onlymandatoryRead Cache Percent. This shows the percent of cache memory allocated for read ahead caching. If the data cannot be determined or is not applicable, the value i…
1.3.6.1.4.1.232.3.2.2.2.1.14ColumncpqDaAccelWriteCachePercentread-onlymandatoryWrite Cache Percent. This shows the percent of cache memory allocated for posted write caching. If the data cannot be determined or is not applicable, the valu…
1.3.6.1.4.1.232.3.2.2.2.1.15ColumncpqDaAccelFailedBatteriesread-onlymandatoryCache Module Failed Batteries. This lists the location of cache module failed batteries. Each octet present contains the position number of a failed battery. A…
1.3.6.1.4.1.232.3.2.2.2.1.16ColumncpqDaAccelBackupPowerSourceread-onlymandatoryCache Module Board Backup Power Source. This describes the backup power source being used by the Cache Module board. The status can be: Other (1) Indicates tha…
1.3.6.1.4.1.232.3.2.2.2.1.17ColumncpqDaAccelBoardCurrentTempread-onlymandatoryCache Module Board Current Temperature. This is the temperature of the cache module board in degrees Celsius. The field will contain -1 if the cache module boa…
1.3.6.1.4.1.232.3.2.2.2.1.18ColumncpqDaAccelCapacitorCurrentTempread-onlymandatoryCache Module Capacitor Current Temperature. This is the temperature of the Super-Cap in degrees Celsius. The field will contain -1 if the Super-Cap temperature…
1.3.6.1.4.1.232.3.2.2.2.1.19ColumncpqDaAccelMemoryDataWidthread-onlymandatoryCache Memory Data Width. This is the memory data width (in bits), for the attached cache module. The field will contain -1 if the memory data width cannot be c…
1.3.6.1.4.1.232.3.2.2.2.1.20ColumncpqDaAccelMemoryTransferRateread-onlymandatoryCache Memory Transfer Rate. This is the memory transfer rate in megatransfers per second (MT/s), for the attached cache module . The field will contain -1 if t…
1.3.6.1.4.1.232.3.2.2.3TablecpqDaManagedCableTablenot-accessiblemandatoryDrive Array Managed Cable Table.
1.3.6.1.4.1.232.3.2.2.3.1RowcpqDaManagedCableEntrynot-accessiblemandatoryDrive Array Managed Cable Entry.
1.3.6.1.4.1.232.3.2.2.3.1.1ColumncpqDaManagedCableIndexread-onlymandatoryManaged Cable Index. This index identifies a controller and managed cable association. This index uniquely identifies a single managed cable connected to a con…
1.3.6.1.4.1.232.3.2.2.3.1.2ColumncpqDaManagedCableCntlrIndexread-onlymandatoryManaged Cable Controller Index. This value maps the managed cables into their respective controllers. This value is a logical number whose meaning is OS depend…
1.3.6.1.4.1.232.3.2.2.3.1.3ColumncpqDaManagedCableHostConnectorread-onlymandatoryManaged Cable Host Connector. This is the port connector to which the managed cable is attached. If the host connector cannot be determined, the agent will ret…
1.3.6.1.4.1.232.3.2.2.3.1.4ColumncpqDaManagedCableStatusread-onlymandatoryManaged Cable Status. The following values are defined: Other (1) Indicates that the instrument agent can not determine the managed cable status. Ok (2) Indica…
1.3.6.1.4.1.232.3.2.2.3.1.5ColumncpqDaManagedCableFaultCoderead-onlymandatoryManaged Cable Fault Code. The following values are defined: Other (1) Indicates that the instrument agent can not determine the managed cable fault code. None …
1.3.6.1.4.1.232.3.2.2.3.1.6ColumncpqDaManagedCableVendorRevisionread-onlymandatoryManaged Cable Vendor Revision. Indicates the vendor revision of the managed cable. If the managed cable does not support vendor revision, the instrument agent …
1.3.6.1.4.1.232.3.2.2.3.1.7ColumncpqDaManagedCableVendorSerialNumberread-onlymandatoryManaged Cable Vendor Serial Number. Indicates the vendor serial number of the managed cable. If the managed cable does not support vendor serial number, the in…
1.3.6.1.4.1.232.3.2.2.3.1.8ColumncpqDaManagedCableVendorPartNumberread-onlymandatoryManaged Cable Vendor Part Number. Indicates the vendor part number of the managed cable. If the managed cable does not support vendor part number, the instrume…
1.3.6.1.4.1.232.3.2.2.3.1.9ColumncpqDaManagedCableLengthread-onlymandatoryManaged Cable Length. Indicates the length of the managed cable in meters. This field will contain -1 if the cable length cannot be determined or if the manage…
1.3.6.1.4.1.232.3.2.3NodecpqDaLogDrv
1.3.6.1.4.1.232.3.2.3.1TablecpqDaLogDrvTablenot-accessiblemandatoryDrive Array Logical Drive Table. A table of logical drive entries.
1.3.6.1.4.1.232.3.2.3.1.1RowcpqDaLogDrvEntrynot-accessiblemandatoryDrive Array Logical Drive Entry. A logical drive entry.
1.3.6.1.4.1.232.3.2.3.1.1.1ColumncpqDaLogDrvCntlrIndexread-onlymandatoryDrive Array Logical Drive Controller Index. This maps the logical drives into their respective controllers. Controller index `i` under the controller group own…
1.3.6.1.4.1.232.3.2.3.1.1.2ColumncpqDaLogDrvIndexread-onlymandatoryDrive Array Logical Drive Index. This logical drive number keeps track of multiple instances of logical drives which are on the same controller. For each contr…
1.3.6.1.4.1.232.3.2.3.1.1.3ColumncpqDaLogDrvFaultTolread-onlymandatoryLogical Drive Fault Tolerance. This shows the fault tolerance mode of the logical drive. The following values are valid for the Logical Drive Fault Tolerance: …
1.3.6.1.4.1.232.3.2.3.1.1.4ColumncpqDaLogDrvStatusread-onlymandatoryLogical Drive Status. The logical drive can be in one of the following states: Ok (2) Indicates that the logical drive is in normal operation mode. Failed (3) …
1.3.6.1.4.1.232.3.2.3.1.1.5ColumncpqDaLogDrvAutoRelread-writemandatoryArray Controller Logical Drive Auto-Reliability Delay. This value indicates how many seconds the logical drive will wait with no requests before beginning Auto…
1.3.6.1.4.1.232.3.2.3.1.1.6ColumncpqDaLogDrvRebuildBlksread-onlydeprecatedLogical Drive Rebuild Blocks Remaining. After a failed physical drive has been replaced, the physical drive must have its data rebuilt. This value shows how ma…
1.3.6.1.4.1.232.3.2.3.1.1.7ColumncpqDaLogDrvHasAccelread-onlymandatoryLogical Drive Has Cache Module Board. This indicates whether the logical drive has a Cache Module board configured and enabled. The following values are valid:…
1.3.6.1.4.1.232.3.2.3.1.1.8ColumncpqDaLogDrvAvailSparesread-onlydeprecatedDrive Array Logical Drive Available Spares. This indicates if this logical drive has one or more spares designated for it that are not currently in use by anot…
1.3.6.1.4.1.232.3.2.3.1.1.9ColumncpqDaLogDrvSizeread-onlymandatoryLogical Drive Size. This is the size of the logical drive in megabytes. This value is calculated using the value 1,048,576 (2^20) as a megabyte. Drive manufact…
1.3.6.1.4.1.232.3.2.3.1.1.10ColumncpqDaLogDrvPhyDrvIDsread-onlydeprecatedDrive Array Logical Drive Physical Drive IDs. This lists the physical drive IDs which are associated with this logical drive. These are the same IDs which can …
1.3.6.1.4.1.232.3.2.3.1.1.11ColumncpqDaLogDrvConditionread-onlymandatoryThe Logical Drive condition. This value represents the overall condition of this logical drive and any associated physical drives.
1.3.6.1.4.1.232.3.2.3.1.1.12ColumncpqDaLogDrvPercentRebuildread-onlymandatoryLogical Drive Percent Rebuild. After a failed physical drive has been replaced, the physical drive must have its data rebuilt. This value is the percent comple…
1.3.6.1.4.1.232.3.2.3.1.1.13ColumncpqDaLogDrvStripeSizeread-onlymandatoryLogical Drive Stripe Size. This is the size of a logical drive stripe in kilobytes.
1.3.6.1.4.1.232.3.2.3.1.1.14ColumncpqDaLogDrvOsNameread-onlymandatoryLogical Drive OS Name. The OS name for this array logical drive. This field will be a null (size 0) string if the agent does not support OS name.
1.3.6.1.4.1.232.3.2.3.1.1.15ColumncpqDaLogDrvBlinkTimeread-writemandatoryLogical Drive Physical Drive Blink Time Count. The logical drive blink time variable allows the drive tray LEDs of all physical drives in a logical drive to bl…
1.3.6.1.4.1.232.3.2.3.1.1.16ColumncpqDaLogDrvSpareReplaceMapread-onlydeprecatedLogical Drive Spare To Replacement Drive Map. This data structure contains the spare to physical drive replacement map. The format is: octet contents ===== ===…
1.3.6.1.4.1.232.3.2.3.1.1.17ColumncpqDaLogDrvRebuildingPhyDrvread-onlymandatoryLogical Drive Physical Drive Rebuilding Index. This is the physical drive index of the physical drive that is currently rebuilding. If the value cannot be dete…
1.3.6.1.4.1.232.3.2.3.1.1.18ColumncpqDaLogDrvMultipathAccessread-onlymandatoryLogical Drive Multi-path Access. This indicates whether all the physical disks including spares of this logical drive have been configured to have and currentl…
1.3.6.1.4.1.232.3.2.3.1.1.19ColumncpqDaLogDrvNmbrOfParityGroupsread-onlymandatoryLogical Drive Number Of Parity Groups. Indicates the number of parity groups (i.e. RAID 4/5/6 subvolumes), that are being striped across.
1.3.6.1.4.1.232.3.2.3.1.1.20ColumncpqDaLogDrvSplitMirrorBackupLogDrvread-onlymandatoryLogical Drive Split Mirror Backup Logical Drive. Indicates if this logical drive is a backup logical drive belonging to a split mirror. The following values ar…
1.3.6.1.4.1.232.3.2.3.1.1.21ColumncpqDaLogDrvCacheVolAccelAssocTyperead-onlymandatoryLogical Drive Cache Volume Accelerator Association Type. Indicates the way in which this logical drive is associated with a cache volume accelerator group. The…
1.3.6.1.4.1.232.3.2.3.1.1.22ColumncpqDaLogDrvCacheVolIndexread-onlymandatoryLogical Drive Cache Volume Index. The logical drive index of the cache volume used by this logical drive. The value of this index is the same as the logical dr…
1.3.6.1.4.1.232.3.2.3.1.1.23ColumncpqDaLogDrvRPIPercentCompleteread-onlymandatoryLogical Drive Rapid Parity Initialization Percent Complete. When a fault tolerant logical volume is created, parity data for the volume must be initialized. Th…
1.3.6.1.4.1.232.3.2.3.1.1.24ColumncpqDaLogDrvSSDSmartPathStatusread-onlymandatoryLogical Drive SSD Smart Path Status. Indicates the logical drive SSD Smart Path status. An SSD Smart Path for a logical drive can be utilized only when both th…
1.3.6.1.4.1.232.3.2.3.1.1.25ColumncpqDaLogDrvEncryptionStatusread-onlymandatoryLogical Drive Encryption Status. Indicates the logical drive encryption status. The following values are defined: Other (1) Indicates that the instrument agent…
1.3.6.1.4.1.232.3.2.3.2TablecpqDaLogDrvPhyDrvExtAttachTablenot-accessiblemandatoryDrive Array Logical Drive Physical Drive Extended Attachment Table. A table of logical drives and their associated physical drives.
1.3.6.1.4.1.232.3.2.3.2.1RowcpqDaLogDrvPhyDrvExtAttachEntrynot-accessiblemandatoryDrive Array Logical Drive Extended Physical Drive Attachment Entry.
1.3.6.1.4.1.232.3.2.3.2.1.1ColumncpqDaLogDrvPhyDrvAttachExtIndexread-onlymandatoryDrive Array Logical Drive Extended Attach Index. This index identifies a controller, logical drive and physical drive connection. This index uniquely identifie…
1.3.6.1.4.1.232.3.2.3.2.1.2ColumncpqDaLogDrvCntlrExtendedread-onlymandatoryDrive Array Logical Drive Controller Extended. This maps the logical drives into their respective controllers. This value is a logical number whose meaning is …
1.3.6.1.4.1.232.3.2.3.2.1.3ColumncpqDaLogDrvLogDrvExtendedread-onlymandatoryDrive Array Logical Drive Extended. This logical drive number keeps track of multiple instances of logical drives which are on the same controller. For each co…
1.3.6.1.4.1.232.3.2.3.2.1.4ColumncpqDaLogDrvPhyDrvExtendedread-onlymandatoryDrive Array Logical Drive Physical Drive Extended. This value is used for selecting the physical drive number in the table entry. This number keeps track of mu…
1.3.6.1.4.1.232.3.2.3.3TablecpqDaLogDrvSprRplcExtAttachTablenot-accessiblemandatoryDrive Array Logical Drive Spare Replacement Extended Attachment Table. A table of logical drives, physical drives and their replacement drives. If spare drives…
1.3.6.1.4.1.232.3.2.3.3.1RowcpqDaLogDrvSprRplcExtAttachEntrynot-accessiblemandatoryDrive Array Logical Drive Spare Replacement Extended Attachment Entry.
1.3.6.1.4.1.232.3.2.3.3.1.1ColumncpqDaLogDrvSprRplcAttachExtIndexread-onlymandatoryDrive Array Logical Drive Spare Replacment Extended Attach Index. This index uniquely identifies a controller, logical drive, physical drive and replacement dr…
1.3.6.1.4.1.232.3.2.3.3.1.2ColumncpqDaLogDrvSprRplcCntlrExtendedread-onlymandatoryDrive Array Logical Drive Spare Replacement Controller Extended. This value maps the spare replacement drives into their respective controllers. This value is …
1.3.6.1.4.1.232.3.2.3.3.1.3ColumncpqDaLogDrvSprRplcLogDrvExtendedread-onlymandatoryDrive Array Logical Drive Spare Replace Logical Drive Extended. This logical drive number keeps track of multiple instances of logical drives which are on the …
1.3.6.1.4.1.232.3.2.3.3.1.4ColumncpqDaLogDrvSprRplcReplacedPhysDrvExtendedread-onlymandatoryDrive Array Logical Drive Spare Replace Replaced Physical Drive Extended. This is the replaced drive physical drive number.
1.3.6.1.4.1.232.3.2.3.3.1.5ColumncpqDaLogDrvSprRplcSparePhysDrvExtendedread-onlymandatoryDrive Array Logical Drive Spare Replace Spare Physical Drive Extended. This is the replacement spare physical drive number.
1.3.6.1.4.1.232.3.2.3.4TablecpqDaLogDrvAvalSprExtAttachTablenot-accessiblemandatoryDrive Array Logical Drive Available Spare Extended Attachment Table. A table of logical drives and their available spare drives. This table indicates when a lo…
1.3.6.1.4.1.232.3.2.3.4.1RowcpqDaLogDrvAvalSprExtAttachEntrynot-accessiblemandatoryDrive Array Logical Drive Available Spare Extended Attachment Entry.
1.3.6.1.4.1.232.3.2.3.4.1.1ColumncpqDaLogDrvAvailSprAttachExtIndexread-onlymandatoryDrive Array Logical Drive Available Spare Extended Attach Index. This index uniquely identifies a controller, logical drive and available spare drive connectio…
1.3.6.1.4.1.232.3.2.3.4.1.2ColumncpqDaLogDrvAvailSprCntlrExtendedread-onlymandatoryDrive Array Logical Drive Available Spare Controller Extended. This value maps the available spare drives into their respective controllers This value is a log…
1.3.6.1.4.1.232.3.2.3.4.1.3ColumncpqDaLogDrvAvailSprLogDrvExtendedread-onlymandatoryDrive Array Logical Drive Available Spare Logical Drive Extended. This logical drive number keeps track of multiple instances of logical drives which are on th…
1.3.6.1.4.1.232.3.2.3.4.1.4ColumncpqDaLogDrvAvailSprAvailableSpareExtendedread-onlymandatoryDrive Array Logical Drive Available Spare Available Spare Extended. This is the available spare drive number assigned to one or more logical drives.
1.3.6.1.4.1.232.3.2.3.5TablecpqDaLogDrvCacheVolumeAccelTablenot-accessiblemandatoryDrive Array Logical Drive Cache Volume Accelerator Table. The cpqDaLogDrvCacheVolumeAccelTable table contains configuration and statistical information about c…
1.3.6.1.4.1.232.3.2.3.5.1RowcpqDaLogDrvCacheVolumeAccelEntrynot-accessiblemandatoryDrive Array Logical Drive Cache Volume Accelerator Entry. A cache volume entry.
1.3.6.1.4.1.232.3.2.3.5.1.1ColumncpqDaLogDrvCacheVolAccelCntlrIndexread-onlymandatoryDrive Array Logical Drive Cache Volume Accelerator Controller Index. This index maps the cache volume back to the controller to which it is attached. The value…
1.3.6.1.4.1.232.3.2.3.5.1.2ColumncpqDaLogDrvCacheVolAccelLogDrvIndexread-onlymandatoryDrive Array Logical Drive Cache Volume Accelerator Logical Drive Index. The logical drive index for this cache volume. The value of this index is the same as t…
1.3.6.1.4.1.232.3.2.3.5.1.3ColumncpqDaLogDrvCacheVolAccelCachingAlgorithmread-onlymandatoryDrive Array Logical Drive Cache Volume Accelerator Caching Algorithm. The caching algorithm currently in use for the cache volume. The following values are def…
1.3.6.1.4.1.232.3.2.3.5.1.4ColumncpqDaLogDrvCacheVolAccelCacheStateread-onlymandatoryDrive Array Logical Drive Cache Volume Accelerator Cache State. The current cache state of the cache volume. The following values are defined: Other(1) The ins…
1.3.6.1.4.1.232.3.2.3.5.1.5ColumncpqDaLogDrvCacheVolAccelWritePolicyread-onlymandatoryDrive Array Logical Drive Cache Volume Accelerator Write Policy. The write policy that the cache volume has been configured to use. The following values are de…
1.3.6.1.4.1.232.3.2.3.5.1.6ColumncpqDaLogDrvCacheVolAccelNoOfReadHitsHread-onlymandatoryDrive Array Logical Drive Cache Volume Accelerator Number Of Read Cache Hits (high). cpqDaLogDrvCacheVolAccelNoOfReadHitsH and cpqDaLogDrvCacheVolAccelNoOfRead…
1.3.6.1.4.1.232.3.2.3.5.1.7ColumncpqDaLogDrvCacheVolAccelNoOfReadHitsread-onlymandatoryDrive Array Logical Drive Cache Volume Accelerator Number Of Read Cache Hits (low). cpqDaLogDrvCacheVolAccelNoOfReadHits and cpqDaLogDrvCacheVolAccelNoOfReadHi…
1.3.6.1.4.1.232.3.2.3.5.1.8ColumncpqDaLogDrvCacheVolAccelNoOfReadMissDoLoadHread-onlymandatoryDrive Array Logical Drive Cache Volume Accelerator Number Of Read Cache Misses - Do Load (high). cpqDaLogDrvCacheVolAccelNoOfReadMissDoLoadH and cpqDaLogDrvCac…
1.3.6.1.4.1.232.3.2.3.5.1.9ColumncpqDaLogDrvCacheVolAccelNoOfReadMissDoLoadread-onlymandatoryDrive Array Logical Drive Cache Volume Accelerator Number Of Read Cache Misses - Do Load (low). cpqDaLogDrvCacheVolAccelNoOfReadMissDoLoad and cpqDaLogDrvCache…
1.3.6.1.4.1.232.3.2.3.5.1.10ColumncpqDaLogDrvCacheVolAccelNoOfReadMissLoadingHread-onlymandatoryDrive Array Logical Drive Cache Volume Accelerator Number Of Read Cache Misses - Loading (high). cpqDaLogDrvCacheVolAccelNoOfReadMissLoadingH and cpqDaLogDrvCa…
1.3.6.1.4.1.232.3.2.3.5.1.11ColumncpqDaLogDrvCacheVolAccelNoOfReadMissLoadingread-onlymandatoryDrive Array Logical Drive Cache Volume Accelerator Number Of Read Cache Misses - Loading (low). cpqDaLogDrvCacheVolAccelNoOfReadMissLoading and cpqDaLogDrvCach…
1.3.6.1.4.1.232.3.2.3.5.1.12ColumncpqDaLogDrvCacheVolAccelNoOfReadMissSkipHread-onlymandatoryDrive Array Logical Drive Cache Volume Accelerator Number Of Read Cache Misses - Skip (high). cpqDaLogDrvCacheVolAccelNoOfReadMissSkipH and cpqDaLogDrvCacheVol…
1.3.6.1.4.1.232.3.2.3.5.1.13ColumncpqDaLogDrvCacheVolAccelNoOfReadMissSkipread-onlymandatoryDrive Array Logical Drive Cache Volume Accelerator Number Of Read Cache Misses - Skip (low). cpqDaLogDrvCacheVolAccelNoOfReadMissSkip and cpqDaLogDrvCacheVolAc…
1.3.6.1.4.1.232.3.2.3.5.1.14ColumncpqDaLogDrvCacheVolAccelReadCacheHitRateread-onlymandatoryDrive Array Logical Drive Cache Volume Accelerator Read Cache Hit Rate. The rate (percentage) that the read cache for this cache volume is being utilized. If t…
1.3.6.1.4.1.232.3.2.3.5.1.15ColumncpqDaLogDrvCacheVolAccelNoOfWriteHitsHread-onlymandatoryDrive Array Logical Drive Cache Volume Accelerator Number Of Write Cache Hits (high). cpqDaLogDrvCacheVolAccelNoOfWriteHitsH and cpqDaLogDrvCacheVolAccelNoOfWr…
1.3.6.1.4.1.232.3.2.3.5.1.16ColumncpqDaLogDrvCacheVolAccelNoOfWriteHitsread-onlymandatoryDrive Array Logical Drive Cache Volume Accelerator Number Of Write Cache Hits (low). cpqDaLogDrvCacheVolAccelNoOfWriteHits and cpqDaLogDrvCacheVolAccelNoOfWrit…
1.3.6.1.4.1.232.3.2.3.5.1.17ColumncpqDaLogDrvCacheVolAccelNoOfWriteMissDoLoadHread-onlymandatoryDrive Array Logical Drive Cache Volume Accelerator Number Of Write Cache Misses - Do Load (high). cpqDaLogDrvCacheVolAccelNoOfWriteMissDoLoadH and cpqDaLogDrvC…
1.3.6.1.4.1.232.3.2.3.5.1.18ColumncpqDaLogDrvCacheVolAccelNoOfWriteMissDoLoadread-onlymandatoryDrive Array Logical Drive Cache Volume Accelerator Number Of Write Cache Misses - Do Load (low). cpqDaLogDrvCacheVolAccelNoOfWriteMissDoLoad and cpqDaLogDrvCac…
1.3.6.1.4.1.232.3.2.3.5.1.19ColumncpqDaLogDrvCacheVolAccelNoOfWriteMissLoadingHread-onlymandatoryDrive Array Logical Drive Cache Volume Accelerator Number Of Write Cache Misses - Loading (high). cpqDaLogDrvCacheVolAccelNoOfWriteMissLoadingH and cpqDaLogDrv…
1.3.6.1.4.1.232.3.2.3.5.1.20ColumncpqDaLogDrvCacheVolAccelNoOfWriteMissLoadingread-onlymandatoryDrive Array Logical Drive Cache Volume Accelerator Number Of Write Cache Misses - Loading (low). cpqDaLogDrvCacheVolAccelNoOfWriteMissLoading and cpqDaLogDrvCa…
1.3.6.1.4.1.232.3.2.3.5.1.21ColumncpqDaLogDrvCacheVolAccelNoOfWriteMissSkipHread-onlymandatoryDrive Array Logical Drive Cache Volume Accelerator Number Of Write Cache Misses - Skip (high). cpqDaLogDrvCacheVolAccelNoOfWriteMissSkipH and cpqDaLogDrvCacheV…
1.3.6.1.4.1.232.3.2.3.5.1.22ColumncpqDaLogDrvCacheVolAccelNoOfWriteMissSkipread-onlymandatoryDrive Array Logical Drive Cache Volume Accelerator Number Of Write Cache Misses - Skip (low). cpqDaLogDrvCacheVolAccelNoOfWriteMissSkip and cpqDaLogDrvCacheVol…
1.3.6.1.4.1.232.3.2.3.5.1.23ColumncpqDaLogDrvCacheVolAccelWriteCacheHitRateread-onlymandatoryDrive Array Logical Drive Cache Volume Accelerator Write Cache Hit Rate. The rate (percentage) that the write cache for this cache volume is being utilized. If…
1.3.6.1.4.1.232.3.2.3.5.1.24ColumncpqDaLogDrvCacheVolAccelLoadFailuresread-onlymandatoryDrive Array Logical Drive Cache Volume Accelerator Load Failures. The number of times data failed to load onto this cache volume due to an error. If the value …
1.3.6.1.4.1.232.3.2.3.5.1.25ColumncpqDaLogDrvCacheVolAccelCacheLineSizeread-onlymandatoryDrive Array Logical Drive Cache Volume Accelerator Cache Line Size. cpqDaLogDrvCacheVolAccelCacheLineSize is the cache line size in number of blocks. If the va…
1.3.6.1.4.1.232.3.2.3.5.1.26ColumncpqDaLogDrvCacheVolAccelNoOfReadMissLockedHread-onlymandatoryDrive Array Logical Drive Cache Volume Accelerator Number Of Read Cache Misses - Locked (high). cpqDaLogDrvCacheVolAccelNoOfReadMissLockedH and cpqDaLogDrvCach…
1.3.6.1.4.1.232.3.2.3.5.1.27ColumncpqDaLogDrvCacheVolAccelNoOfReadMissLockedread-onlymandatoryDrive Array Logical Drive Cache Volume Accelerator Number Of Read Cache Misses - Locked (low). cpqDaLogDrvCacheVolAccelNoOfReadMissLocked and cpqDaLogDrvCacheV…
1.3.6.1.4.1.232.3.2.3.5.1.28ColumncpqDaLogDrvCacheVolAccelNoOfWriteMissLockedHread-onlymandatoryDrive Array Logical Drive Cache Volume Accelerator Number Of Write Cache Misses - Locked (high). cpqDaLogDrvCacheVolAccelNoOfWriteMissLockedH and cpqDaLogDrvCa…
1.3.6.1.4.1.232.3.2.3.5.1.29ColumncpqDaLogDrvCacheVolAccelNoOfWriteMissLockedread-onlymandatoryDrive Array Logical Drive Cache Volume Accelerator Number Of Read Cache Misses - Locked (low). cpqDaLogDrvCacheVolAccelNoOfWriteMissLocked and cpqDaLogDrvCache…
1.3.6.1.4.1.232.3.2.3.5.1.30ColumncpqDaLogDrvCacheVolAccelNoOfReadMissTotalHread-onlymandatoryDrive Array Logical Drive Cache Volume Accelerator Number Of Read Cache Misses - Total (high). cpqDaLogDrvCacheVolAccelNoOfReadMissTotalH and cpqDaLogDrvCacheV…
1.3.6.1.4.1.232.3.2.3.5.1.31ColumncpqDaLogDrvCacheVolAccelNoOfReadMissTotalread-onlymandatoryDrive Array Logical Drive Cache Volume Accelerator Number Of Read Cache Misses - Total (low). cpqDaLogDrvCacheVolAccelNoOfReadMissTotal and cpqDaLogDrvCacheVol…
1.3.6.1.4.1.232.3.2.3.5.1.32ColumncpqDaLogDrvCacheVolAccelNoOfWriteMissTotalHread-onlymandatoryDrive Array Logical Drive Cache Volume Accelerator Number Of Write Cache Misses - Total (high). cpqDaLogDrvCacheVolAccelNoOfWriteMissTotalH and cpqDaLogDrvCach…
1.3.6.1.4.1.232.3.2.3.5.1.33ColumncpqDaLogDrvCacheVolAccelNoOfWriteMissTotalread-onlymandatoryDrive Array Logical Drive Cache Volume Accelerator Number Of Write Cache Misses - Total (low). cpqDaLogDrvCacheVolAccelNoOfReadMissTotal and cpqDaLogDrvCacheVo…
1.3.6.1.4.1.232.3.2.4NodecpqDaSpareDrv
1.3.6.1.4.1.232.3.2.4.1TablecpqDaSpareTablenot-accessiblemandatoryDrive Array Spare Table. A table of spare entries.
1.3.6.1.4.1.232.3.2.4.1.1RowcpqDaSpareEntrynot-accessiblemandatoryDrive Array Spare Entry. An entry in the spare table.
1.3.6.1.4.1.232.3.2.4.1.1.1ColumncpqDaSpareCntlrIndexread-onlymandatoryDrive Array Spare Controller Index. This index maps the spare drive back to the controller to which it is attached. The value of this index is the same as the …
1.3.6.1.4.1.232.3.2.4.1.1.2ColumncpqDaSparePhyDrvIndexread-onlymandatoryDrive Array Spare Physical Drive Index. This index maps the spare to the physical drive it represents. The value of this index is the same as the one used with…
1.3.6.1.4.1.232.3.2.4.1.1.3ColumncpqDaSpareStatusread-onlymandatorySpare Status. This shows the status of the on-line spare drive. The following values are valid for the spare status: Failed (3) The on-line spare has failed an…
1.3.6.1.4.1.232.3.2.4.1.1.4ColumncpqDaSpareReplacedDrvread-onlymandatorySpare Replaced Drive. If the spare status is active(6) or building(5), then this has the physical drive number of the replaced drive. Otherwise a value of -1 w…
1.3.6.1.4.1.232.3.2.4.1.1.5ColumncpqDaSpareRebuildBlksread-onlydeprecatedDrive Array Spare Number Of Rebuild Blocks Left. If the spare status is building(5), then this is the number of blocks left to rebuild before completion. The d…
1.3.6.1.4.1.232.3.2.4.1.1.6ColumncpqDaSpareConditionread-onlymandatoryThe Spare Drive condition. This value represents the overall condition of this spare drive and any associated physical drives.
1.3.6.1.4.1.232.3.2.4.1.1.7ColumncpqDaSpareBusNumberread-onlymandatorySpare Drive SCSI Bus Number. The bus number indicates to which SCSI bus this spare drive is attached. The first instance is one and increments for each SCSI bu…
1.3.6.1.4.1.232.3.2.4.1.1.8ColumncpqDaSpareBayread-onlymandatorySpare Drive Bay Location. This value matches the bay location where the physical drive has been installed. For a SCSI drive, this is the SCSI ID of the drive.
1.3.6.1.4.1.232.3.2.4.1.1.9ColumncpqDaSpareReplacedDrvBusNumberread-onlymandatorySpare Replaced Drive Bus Number. If the spare status is active(6) or building(5), then this has the physical drive bus number of the replaced drive. If the val…
1.3.6.1.4.1.232.3.2.4.1.1.10ColumncpqDaSpareReplacedDrvBayread-onlymandatorySpare Replaced Drive Bay. If the spare status is active(6) or building(5), then this has the physical drive bay number of the replaced drive. If the value cann…
1.3.6.1.4.1.232.3.2.4.1.1.11ColumncpqDaSparePercentRebuildread-onlymandatoryDrive Array Spare Percent Rebuild. If the spare status is building(5), then this is percent complete of of the rebuild. The data contained on the failed physic…
1.3.6.1.4.1.232.3.2.4.1.1.12ColumncpqDaSpareLocationStringread-onlymandatorySpare Drive Location String. This string describes the location of the drive in relation to the controller. If the location string cannot be determined, the ag…
1.3.6.1.4.1.232.3.2.5NodecpqDaPhyDrv
1.3.6.1.4.1.232.3.2.5.1TablecpqDaPhyDrvTablenot-accessiblemandatoryDrive Array Physical Drive Table. A table of physical drive entries.
1.3.6.1.4.1.232.3.2.5.1.1RowcpqDaPhyDrvEntrynot-accessiblemandatoryDrive Array Physical Drive Entry. A physical drive entry.
1.3.6.1.4.1.232.3.2.5.1.1.1ColumncpqDaPhyDrvCntlrIndexread-onlymandatoryDrive Array Physical Drive Controller Index. This index maps the physical drive back to the controller to which it is attached. The value of this index is the …
1.3.6.1.4.1.232.3.2.5.1.1.2ColumncpqDaPhyDrvIndexread-onlymandatoryDrive Array Physical Drive Index. This index is used for selecting the physical drive table entry. This number, along with the cpqDaPhyDrvCntlrIndex uniquely i…
1.3.6.1.4.1.232.3.2.5.1.1.3ColumncpqDaPhyDrvModelread-onlymandatoryPhysical Drive Model. This is a text description of the physical drive. The text that appears depends upon who manufactured the drive and the drive type. If a …
1.3.6.1.4.1.232.3.2.5.1.1.4ColumncpqDaPhyDrvFWRevread-onlymandatoryPhysical Drive Firmware Revision. This shows the physical drive revision number. If the firmware revision is not present, you have not properly initialized the…
1.3.6.1.4.1.232.3.2.5.1.1.5ColumncpqDaPhyDrvBayread-onlymandatoryPhysical Drive Bay Location. This value matches the bay location where the physical drive has been installed. For a SCSI drive, this is the SCSI ID of the driv…
1.3.6.1.4.1.232.3.2.5.1.1.6ColumncpqDaPhyDrvStatusread-onlymandatoryPhysical Drive Status. This shows the status of the physical drive. The following values are valid for the physical drive status: Other (1) Indicates that the …
1.3.6.1.4.1.232.3.2.5.1.1.7ColumncpqDaPhyDrvFactReallocsread-onlymandatoryThis shows the number of spare sectors available for remapping at the time the physical drive was shipped. The physical drive will use these spare sectors for …
1.3.6.1.4.1.232.3.2.5.1.1.8ColumncpqDaPhyDrvUsedReallocsread-onlymandatoryPhysical Drive Used Reallocated Sectors. This shows the number of sectors of the reallocation area that have been used by the physical drive. To see how many s…
1.3.6.1.4.1.232.3.2.5.1.1.9ColumncpqDaPhyDrvRefHoursread-onlymandatoryReference Time in hours. This shows the total number of hours that a physical drive has been in operation since the drive was stamped. The drive will have eith…
1.3.6.1.4.1.232.3.2.5.1.1.10ColumncpqDaPhyDrvHReadsread-onlymandatorySectors Read (high). The phyDrvHReads and the phyDrvReads together shows the total number of sectors read from the physical disk drive during the reference tim…
1.3.6.1.4.1.232.3.2.5.1.1.11ColumncpqDaPhyDrvReadsread-onlymandatorySectors Read (low). The phyDrvHReads and the phyDrvReads together shows the total number of sectors read from the physical disk drive during the reference time…
1.3.6.1.4.1.232.3.2.5.1.1.12ColumncpqDaPhyDrvHWritesread-onlymandatorySectors Written (high). The phyDrvHWrites and the phyDrvWrites together shows the total number of sectors written to the physical disk drive during the referen…
1.3.6.1.4.1.232.3.2.5.1.1.13ColumncpqDaPhyDrvWritesread-onlymandatorySectors Written (low). The phyDrvHWrites and the phyDrvWrites together shows the total number of sectors written to the physical disk drive during the referenc…
1.3.6.1.4.1.232.3.2.5.1.1.14ColumncpqDaPhyDrvHSeeksread-onlymandatoryTotal Seeks (high). The phyDrvHSeeks and the phyDrvSeeks together shows the total number of seek operations performed by the physical disk drive during the ref…
1.3.6.1.4.1.232.3.2.5.1.1.15ColumncpqDaPhyDrvSeeksread-onlymandatoryTotal Seeks (low). The phyDrvHSeeks and the phyDrvSeeks together shows the total number of seek operations performed by the physical disk drive during the refe…
1.3.6.1.4.1.232.3.2.5.1.1.16ColumncpqDaPhyDrvHardReadErrsread-onlymandatoryHard Read Errors. This shows the number of read errors that have occurred on a drive that could not be recovered by a physical drive`s Error Correction Code (E…
1.3.6.1.4.1.232.3.2.5.1.1.17ColumncpqDaPhyDrvRecvReadErrsread-onlymandatoryRecovered Read Errors. This shows the number of read errors corrected through physical drive retries during the reference time (phyDrvRefTime). Over time, all …
1.3.6.1.4.1.232.3.2.5.1.1.18ColumncpqDaPhyDrvHardWriteErrsread-onlymandatoryHard Write Errors. This shows the number of write errors that could not be recovered by a physical drive during the reference time (phyDrvRefTime). Over time a…
1.3.6.1.4.1.232.3.2.5.1.1.19ColumncpqDaPhyDrvRecvWriteErrsread-onlymandatoryRecovered Write Errors. This shows the number of write errors corrected through physical drive retries or recovered by a physical drive during the reference ti…
1.3.6.1.4.1.232.3.2.5.1.1.20ColumncpqDaPhyDrvHSeekErrsread-onlymandatorySeek Errors (High). The phyDrvHSeekErrs and the phyDrvSeekErrs together shows the total number of times that the physical disk drive detected a seek error duri…
1.3.6.1.4.1.232.3.2.5.1.1.21ColumncpqDaPhyDrvSeekErrsread-onlymandatorySeek Errors (low). The phyDrvHSeekErrs and the phyDrvSeekErrs together shows the total number of times that the physical disk drive detected a seek error durin…
1.3.6.1.4.1.232.3.2.5.1.1.22ColumncpqDaPhyDrvSpinupTimeread-onlymandatorySpin up Time in tenths of seconds. This is the time it takes for a physical drive to spin up to full speed. Disks require time to gain momentum and reach opera…
1.3.6.1.4.1.232.3.2.5.1.1.23ColumncpqDaPhyDrvFunctTest1read-onlydeprecatedFunctional Test 1. This provides information about a series of tests that indicate how well a physical drive works. These tests compare the way the physical dr…
1.3.6.1.4.1.232.3.2.5.1.1.24ColumncpqDaPhyDrvFunctTest2read-onlydeprecatedFunctional Test 2. This provides information about a series of tests that indicate how well a physical drive works. These tests compare the way the physical dr…
1.3.6.1.4.1.232.3.2.5.1.1.25ColumncpqDaPhyDrvFunctTest3read-onlydeprecatedFunctional Test 3. This provides information about a series of tests that indicate how well a physical drive works. These tests compare the way the physical dr…
1.3.6.1.4.1.232.3.2.5.1.1.26ColumncpqDaPhyDrvDrqTimeoutsread-onlymandatoryDRQ Timeouts. The number of times that a physical drive continued to request data, but did not get a command completion during the reference time (phyDrvRefTim…
1.3.6.1.4.1.232.3.2.5.1.1.27ColumncpqDaPhyDrvOtherTimeoutsread-onlymandatoryOther Timeouts. The number of times that a physical drive did not respond with an interrupt within a controller-defined period of time after a command had been…
1.3.6.1.4.1.232.3.2.5.1.1.28ColumncpqDaPhyDrvSpinupRetriesread-onlymandatorySpin up Retries. The number of times that a physical drive had to retry to spin up before successfully achieving operating speed during the reference time (phy…
1.3.6.1.4.1.232.3.2.5.1.1.29ColumncpqDaPhyDrvBadRecvReadsread-onlymandatoryRecovery Failed (Bad) Read Error. The number of times a read error occurred while performing Automatic Data Recovery from this physical drive to another drive …
1.3.6.1.4.1.232.3.2.5.1.1.30ColumncpqDaPhyDrvBadRecvWritesread-onlymandatoryRecovery Failed (Bad) Write Error. The number of times a write error occurred while performing Automatic Data Recovery from another drive to this physical driv…
1.3.6.1.4.1.232.3.2.5.1.1.31ColumncpqDaPhyDrvFormatErrsread-onlymandatoryFormat Error. The number of times a format operation failed when the controller attempted to remap a bad sector during the reference time (phyDrvRefTime). Zero…
1.3.6.1.4.1.232.3.2.5.1.1.32ColumncpqDaPhyDrvPostErrsread-onlymandatoryPower On Self Test (Post) Error. The number of times that a physical drive failed its self test during the reference time (phyDrvRefTime). The physical drive d…
1.3.6.1.4.1.232.3.2.5.1.1.33ColumncpqDaPhyDrvNotReadyErrsread-onlymandatoryDrive Not Ready Errors. The number of times the physical drive failed after the spin up command was issued during the reference time (phyDrvRefTime). When the …
1.3.6.1.4.1.232.3.2.5.1.1.34ColumncpqDaPhyDrvReallocAbortsread-onlymandatoryPhysical Drive Reallocation Aborts. The number of times the physical drive has failed due to an error that occurred when the controller was trying to reallocat…
1.3.6.1.4.1.232.3.2.5.1.1.35ColumncpqDaPhyDrvThreshPassedread-onlymandatoryPhysical Drive Factory Threshold Passed (Exceeded). When the drive is shipped, certain thresholds have been set to monitor performance of the drives. For examp…
1.3.6.1.4.1.232.3.2.5.1.1.36ColumncpqDaPhyDrvHasMonInforead-onlymandatoryPhysical Drive Has Monitor Information. All of the physical disk table fields except for the physical disk status (phyDrvStatus) and the bay location (phyDrvBa…
1.3.6.1.4.1.232.3.2.5.1.1.37ColumncpqDaPhyDrvConditionread-onlymandatoryThe condition of the device. This value represents the overall condition of this physical drive.
1.3.6.1.4.1.232.3.2.5.1.1.38ColumncpqDaPhyDrvHotPlugsread-onlymandatoryPhysical Drive Hot Plug Count. This value indicates the number of times this physical drive was hot-plugged (removed) from a ProLiant Storage System. This is n…
1.3.6.1.4.1.232.3.2.5.1.1.39ColumncpqDaPhyDrvMediaErrsread-onlymandatoryPhysical Drive Media Failure Count. This value indicates the number of times this physical drive was failed due to unrecoverable media errors. This is not supp…
1.3.6.1.4.1.232.3.2.5.1.1.40ColumncpqDaPhyDrvHardwareErrsread-onlymandatoryPhysical Drive Hardware Error Count. This value indicates the number of times this physical drive returned a bad hardware status. The drive may be failed if re…
1.3.6.1.4.1.232.3.2.5.1.1.41ColumncpqDaPhyDrvAbortedCmdsread-onlymandatoryPhysical Drive Aborted Command Failures. This value indicates the number of times this physical drive was failed due to aborted commands that could not be retr…
1.3.6.1.4.1.232.3.2.5.1.1.42ColumncpqDaPhyDrvSpinUpErrsread-onlymandatoryPhysical Drive Spin-Up Failure Count. This value indicates the number of times this physical drive was failed due to a failure of a spin-up command. This is no…
1.3.6.1.4.1.232.3.2.5.1.1.43ColumncpqDaPhyDrvBadTargetErrsread-onlymandatoryPhysical Drive Bad Target Count. This value indicates the number of times this physical drive performed some action that did not conform to the SCSI-2 bus prot…
1.3.6.1.4.1.232.3.2.5.1.1.44ColumncpqDaPhyDrvLocationread-onlydeprecatedDrive Physical Location. This is the physical location of where the drive is located. The following values are defined: other(1) The location of the drive is n…
1.3.6.1.4.1.232.3.2.5.1.1.45ColumncpqDaPhyDrvSizeread-onlymandatoryPhysical Drive Size in MB. This is the size of the physical drive in megabytes. This value is calculated using the value 1,048,576 (2^20) as a megabyte. Drive …
1.3.6.1.4.1.232.3.2.5.1.1.46ColumncpqDaPhyDrvBusFaultsread-onlymandatoryPhysical Drive Bus Fault Count. This value indicates the number of times that a bus fault was detected for the drive by the controller. This is not supported b…
1.3.6.1.4.1.232.3.2.5.1.1.47ColumncpqDaPhyDrvIrqDeglitchesread-onlymandatoryPhysical Drive IRQ Deglitch Count. This is not supported by the IDA, IDA Expansion, or IDA-2 controllers.
1.3.6.1.4.1.232.3.2.5.1.1.48ColumncpqDaPhyDrvHotPlugread-onlymandatoryPhysical Drive Hot Plug Support Status. The following values are defined: other(1) The Insight Agent is unable to determine if this drive supports hot plug rep…
1.3.6.1.4.1.232.3.2.5.1.1.49ColumncpqDaPhyDrvPlacementread-onlymandatoryPhysical Drive Placement. The following values are defined: other(1) The agent is unable to determine if the drive is internal or external to the system chassi…
1.3.6.1.4.1.232.3.2.5.1.1.50ColumncpqDaPhyDrvBusNumberread-onlymandatoryPhysical Drive SCSI Bus Number. The bus number indicates to which SCSI bus this physical drive is attached. The first instance is one and increments for each S…
1.3.6.1.4.1.232.3.2.5.1.1.51ColumncpqDaPhyDrvSerialNumread-onlymandatoryPhysical Drive Serial Number. This is the serial number assigned to the physical drive. This value is based upon the serial number as returned by the SCSI inqu…
1.3.6.1.4.1.232.3.2.5.1.1.52ColumncpqDaPhyDrvPreFailMonitoringread-onlymandatoryDrive Array Physical Drive Predictive Failure Monitoring. The following values are defined: other(1) The agent is unable to determine if the drive supports pre…
1.3.6.1.4.1.232.3.2.5.1.1.53ColumncpqDaPhyDrvCurrentWidthread-onlymandatoryDrive Array Physical Drive Current Width. The following values are defined: other(1) The agent is unable to determine the current negotiated data transfer widt…
1.3.6.1.4.1.232.3.2.5.1.1.54ColumncpqDaPhyDrvCurrentSpeedread-onlymandatoryDrive Array Physical Drive Current Data Transfer Speed. The following values are defined: other(1) The agent is unable to determine the current negotiated data…
1.3.6.1.4.1.232.3.2.5.1.1.55ColumncpqDaPhyDrvFailureCoderead-onlymandatoryDrive Array Physical Drive Failure Code. This value is the drive failure reason code returned by the array firmware. It is valid only when the drive is failed.…
1.3.6.1.4.1.232.3.2.5.1.1.56ColumncpqDaPhyDrvBlinkTimeread-writemandatoryPhysical Drive Blink Time Count. This value indicates the amount of time, in tenths of a second, that the physical drive LEDs will continue to blink. A value o…
1.3.6.1.4.1.232.3.2.5.1.1.57ColumncpqDaPhyDrvSmartStatusread-onlymandatoryPhysical Drive S.M.A.R.T Status. The following values are defined: other(1) The agent is unable to determine if the status of S.M.A.R.T predictive failure moni…
1.3.6.1.4.1.232.3.2.5.1.1.58ColumncpqDaPhyDrvConfigurationStatusread-onlymandatoryPhysical Drive Configuration Status. The following values are defined: other(1) The agent is unable to determine the configuration status of this physical driv…
1.3.6.1.4.1.232.3.2.5.1.1.59ColumncpqDaPhyDrvRotationalSpeedread-onlymandatoryDrive Array Physical Drive Rotational Speed. The following values are defined: other(1) The agent is unable to determine the rotational speed for this drive. r…
1.3.6.1.4.1.232.3.2.5.1.1.60ColumncpqDaPhyDrvTyperead-onlymandatoryPhysical Drive Type. The following values are defined: other(1) The agent is unable to determine the type for this drive. parallelScsi(2) The drive type is par…
1.3.6.1.4.1.232.3.2.5.1.1.61ColumncpqDaPhyDrvSataVersionread-onlymandatoryPhysical Drive SATA Version. The following values are defined: other(1) The agent is unable to determine the SATA version for this drive or it is not a SATA dr…
1.3.6.1.4.1.232.3.2.5.1.1.62ColumncpqDaPhyDrvHostConnectorread-onlymandatoryPhysical Drive Host Connector. This is the host connector to which the drive is ultimately attached. If the host connector cannot be determined, the agent will…
1.3.6.1.4.1.232.3.2.5.1.1.63ColumncpqDaPhyDrvBoxOnConnectorread-onlymandatoryPhysical Drive Box on Connector. The box on connector indicates to which box instance this physical drive belongs. The instances start at one and increment for…
1.3.6.1.4.1.232.3.2.5.1.1.64ColumncpqDaPhyDrvLocationStringread-onlymandatoryPhysical Drive Location String. This string describes the location of the drive in relation to the controller. If the location string cannot be determined, the…
1.3.6.1.4.1.232.3.2.5.1.1.65ColumncpqDaPhyDrvNegotiatedLinkRateread-onlymandatoryDrive Array Physical Drive Negotiated Link Rate. The following values are defined: other(1) The agent is unable to determine the negotiated link rate this driv…
1.3.6.1.4.1.232.3.2.5.1.1.66ColumncpqDaPhyDrvNcqSupportread-onlymandatoryDrive Array Physical Drive Native Command Queueing. The following values are defined: other(1) The agent is unable to determine the NCQ configuration for this …
1.3.6.1.4.1.232.3.2.5.1.1.67ColumncpqDaPhyDrvPhyCountread-onlymandatoryDrive Array Physical Drive PHY Count. This value indicates how many PHYs exist on SAS/SATA disk. For parallel SCSI disks, this value is set to -1.
1.3.6.1.4.1.232.3.2.5.1.1.68ColumncpqDaPhyDrvMultipathAccessread-onlymandatoryDrive Array Physical Drive Multi-path Access Status. This indicates if this physical drive has been configured to have and currently still has more than one I/…
1.3.6.1.4.1.232.3.2.5.1.1.69ColumncpqDaPhyDrvMediaTyperead-onlymandatoryDrive Array Physical Drive Media Type. The following values are defined: other(1) The instrument agent is unable to determine the media type of physical drive.…
1.3.6.1.4.1.232.3.2.5.1.1.70ColumncpqDaPhyDrvCurrentTemperatureread-onlymandatoryDrive Array Physical Drive Current Temperature. This is the temperature of the physical drive in degrees Celsius. The field will contain -1 if the drive temper…
1.3.6.1.4.1.232.3.2.5.1.1.71ColumncpqDaPhyDrvTemperatureThresholdread-onlymandatoryDrive Array Physical Drive Temperature Threshold. This is the temperature in degrees Celsius at which the drive says it is overheated. The field will contain -…
1.3.6.1.4.1.232.3.2.5.1.1.72ColumncpqDaPhyDrvMaximumTemperatureread-onlymandatoryDrive Array Physical Drive Maximum Temperature. This is the maximum temperature in degrees Celsius that the drive has reached. The field will contain -1 if the…
1.3.6.1.4.1.232.3.2.5.1.1.73ColumncpqDaPhyDrvSSDWearStatusread-onlymandatoryDrive Array Physical Drive Solid State Disk Wear Status. This shows the wear status of the solid state physical drive. The following values are valid for the p…
1.3.6.1.4.1.232.3.2.5.1.1.74ColumncpqDaPhyDrvPowerOnHoursread-onlymandatoryDrive Array Physical Drive Power On Hours. This is the total number of hours that the physical disk has been powered on. This value will be 4,294,967,295 if th…
1.3.6.1.4.1.232.3.2.5.1.1.75ColumncpqDaPhyDrvSSDPercntEndrnceUsedread-onlymandatoryDrive Array Physical Drive Solid State Percent Endurance Used. This value specifies the hundredths of the percentage of solid state disk life used. The value o…
1.3.6.1.4.1.232.3.2.5.1.1.76ColumncpqDaPhyDrvSSDEstTimeRemainingHoursread-onlymandatoryDrive Array Physical Drive Solid State Estimated Time Remaining In Hours. This is the estimated total number of hours that the solid state physical disk has re…
1.3.6.1.4.1.232.3.2.5.1.1.77ColumncpqDaPhyDrvAuthenticationStatusread-onlymandatoryDrive Array Physical Drive Authentication Status. The following values are defined: Other (1) Indicates that the instrument agent can not determine the physica…
1.3.6.1.4.1.232.3.2.5.1.1.78ColumncpqDaPhyDrvSmartCarrierAppFWRevread-onlymandatoryPhysical Drive Smart Carrier Application Firmware Revision. This displays the physical drive smart carrier application firmware revision number. This value wil…
1.3.6.1.4.1.232.3.2.5.1.1.79ColumncpqDaPhyDrvSmartCarrierBootldrFWRevread-onlymandatoryPhysical Drive Smart Carrier Bootloader Firmware Revision. This displays the physical drive smart carrier bootloader firmware revision number. This value will …
1.3.6.1.4.1.232.3.2.5.1.1.80ColumncpqDaPhyDrvEncryptionStatusread-onlymandatoryPhysical Drive Encryption Status. The physical drive`s encryption status. The following values are valid: other (1) Indicates that the instrument agent does no…
1.3.6.1.4.1.232.3.2.5.2TablecpqDaPhyDrvErrTablenot-accessiblemandatoryDrive Array Physical Drive Error Log Table. A table of physical drive entries. The Error Log Table is not supported by the IDA, IDA Expansion, or IDA-2 control…
1.3.6.1.4.1.232.3.2.5.2.1RowcpqDaPhyDrvErrEntrynot-accessiblemandatoryDrive Array Physical Drive Entry.
1.3.6.1.4.1.232.3.2.5.2.1.1ColumncpqDaPhyDrvErrCntlrIndexread-onlymandatoryDrive Array Physical Drive Error Log Controller Index. This index maps the physical drive back to the controller to which it is attached. The value of this ind…
1.3.6.1.4.1.232.3.2.5.2.1.2ColumncpqDaPhyDrvErrIDIndexread-onlymandatoryDrive Array Physical Drive Error Log Index. This index is used for selecting the physical drive table entry. This number, along with the cpqDaPhyDrvErrCntlrInd…
1.3.6.1.4.1.232.3.2.5.2.1.3ColumncpqDaPhyDrvErrIndexread-onlymandatoryDrive Array Physical Drive Error Log Index. This index is used for selecting the physical drive table entry. This number, along with the cpqDaPhyDrvErrCntlrInd…
1.3.6.1.4.1.232.3.2.5.2.1.4ColumncpqDaPhyDrvErrTyperead-onlymandatoryPhysical Drive Error Log Error Type. The type of error in the error log. The valid types are: Other (1) Indicates that the instrument agent does not recognize …
1.3.6.1.4.1.232.3.2.5.2.1.5ColumncpqDaPhyDrvScsiOpread-onlymandatoryPhysical Drive Error Log SCSI Operation. This is the SCSI Command Operation Code byte associated with the error log entry. For further specifications consult a…
1.3.6.1.4.1.232.3.2.5.2.1.6ColumncpqDaPhyDrvScsiStatusread-onlymandatoryPhysical Drive Error Log SCSI Status. This is the SCSI Status Code byte associated with the error log entry. For further specifications consult a SCSI-2 logica…
1.3.6.1.4.1.232.3.2.5.2.1.7ColumncpqDaPhyDrvCamStatusread-onlymandatoryPhysical Drive Error Log CAM Status. This is the SCSI CAM Status byte associated with the error log entry. For further specifications consult a SCSI-2 logical …
1.3.6.1.4.1.232.3.2.5.2.1.8ColumncpqDaPhyDrvSenseKeyread-onlymandatoryPhysical Drive Error Log Sense Key. This is the SCSI Sense Key byte associated with the error log entry. For further specifications consult a SCSI-2 logical sp…
1.3.6.1.4.1.232.3.2.5.2.1.9ColumncpqDaPhyDrvQualifierread-onlymandatoryPhysical Drive Error Log Qualifier. This is the SCSI Additional Sense Code Qualifier byte (as returned by the Request Sense command) associated with the error …
1.3.6.1.4.1.232.3.2.5.2.1.10ColumncpqDaPhyDrvSenseCoderead-onlymandatoryPhysical Drive Error Log Sense Code. This is the SCSI Sense Code associated with the error log entry. For further specifications consult a SCSI-2 logical speci…
1.3.6.1.4.1.232.3.2.5.2.1.11ColumncpqDaPhyDrvBlockValidread-onlymandatoryPhysical Drive Error Log Block Address Is Valid. The valid values are: False (1) Indicates that the Block Address object (cpqDaPhyDrvBlock) is not a valid addr…
1.3.6.1.4.1.232.3.2.5.2.1.12ColumncpqDaPhyDrvBlockread-onlymandatoryPhysical Drive Error Log Block Address. This is the SCSI Block Address (as returned by the Request Sense Command) associated with the error log entry. For furt…
1.3.6.1.4.1.232.3.2.5.2.1.13ColumncpqDaPhyDrvTimeread-onlymandatoryPhysical Drive Error Log Reference Time. This gives a relative time stamp as to when the error log entry occurred. The Reference Time shows the number of hours…
1.3.6.1.4.1.232.3.2.5.2.1.14ColumncpqDaPhyDrvUserDescread-onlydeprecatedPhysical Drive Error Log User Description. This is a string built by the agent which contains the Reference Time (cpqDaPhyDrvTime) and a brief description of t…
1.3.6.1.4.1.232.3.2.5.2.1.15ColumncpqDaPhyDrvErrDescread-onlymandatoryThe index used to display an error associated with a physical drive. This number refers to an entry in a list of error strings enumerating the possible physica…
1.3.6.1.4.1.232.3.2.5.3TablecpqDaPhyDrvPathTablenot-accessiblemandatoryDrive Array Physical Drive Access Path Table. A table of access path entries supporting physical drive multi-path cabling configuration.
1.3.6.1.4.1.232.3.2.5.3.1RowcpqDaPhyDrvPathEntrynot-accessiblemandatoryDrive Array Physical Drive Access Path Entry.
1.3.6.1.4.1.232.3.2.5.3.1.1ColumncpqDaPhyDrvPathCntlrIndexread-onlymandatoryDrive Array Physical Drive Access Path Controller Index. This index maps the physical drive access path back to the controller to which it is attached. The val…
1.3.6.1.4.1.232.3.2.5.3.1.2ColumncpqDaPhyDrvPathDrvIndexread-onlymandatoryDrive Array Physical Drive Access Path Drive Index. This index maps the access path to a physical drive.
1.3.6.1.4.1.232.3.2.5.3.1.3ColumncpqDaPhyDrvPathIndexread-onlymandatoryDrive Array Physical Drive Access Path Index. This path index keeps track of multiple instances of access paths from a controller to a physical drive. This num…
1.3.6.1.4.1.232.3.2.5.3.1.4ColumncpqDaPhyDrvPathStatusread-onlymandatoryPhysical Drive Access Path Status. This shows the status of the physical drive access path. The following values are valid: Other (1) Indicates that the instru…
1.3.6.1.4.1.232.3.2.5.3.1.5ColumncpqDaPhyDrvPathCurrentRoleread-onlymandatoryPhysical Drive Access Path Current Role. This shows the current role of physical drive access path. The following values are valid: Other (1) Indicates that th…
1.3.6.1.4.1.232.3.2.5.3.1.6ColumncpqDaPhyDrvPathHostConnectorread-onlymandatoryPhysical Drive Access Path Host Connector. This is the host connector to which the access path is ultimately attached. If the host connector cannot be determin…
1.3.6.1.4.1.232.3.2.5.3.1.7ColumncpqDaPhyDrvPathBoxOnConnectorread-onlymandatoryPhysical Drive Access Path Box on Connector. The box on connector indicates to which box instance this physical drive access path belongs.
1.3.6.1.4.1.232.3.2.5.3.1.8ColumncpqDaPhyDrvPathLocationStringread-onlymandatoryPhysical Drive Access Path Location String. This string describes the physical drive access path in relation to the controller. If the location string cannot b…
1.3.6.1.4.1.232.3.2.6NodecpqDaPhyDrvThr
1.3.6.1.4.1.232.3.2.6.1TablecpqDaPhyDrvThrTablenot-accessiblemandatoryDrive Array Physical Drive Threshold Table. A table of physical drive threshold entries.
1.3.6.1.4.1.232.3.2.6.1.1RowcpqDaPhyDrvThrEntrynot-accessiblemandatoryDrive Array Physical Drive Threshold Entry. A physical drive threshold entry.
1.3.6.1.4.1.232.3.2.6.1.1.1ColumncpqDaPhyDrvThrCntlrIndexread-onlymandatoryDrive Array Physical Drive Threshold Controller Index. This index maps the physical drive thresholds back to the controller to which it is attached. The value …
1.3.6.1.4.1.232.3.2.6.1.1.2ColumncpqDaPhyDrvThrIndexread-onlymandatoryDrive Array Physical Drive Threshold Index. This index maps the thresholds to a physical drive. The value of this index is the same as the one used with the ph…
1.3.6.1.4.1.232.3.2.6.1.1.3ColumncpqDaPhyDrvThrUsedReallocsread-onlymandatoryUsed Reallocated Sectors Maximum Threshold. This shows the maximum threshold of the reallocation area that has been used by the physical drive. This threshold …
1.3.6.1.4.1.232.3.2.6.1.1.4ColumncpqDaPhyDrvThrRefHoursread-onlymandatoryReference Time Maximum Threshold in hours. This shows the maximum threshold in hours that a physical drive has been spinning since the drive was stamped. This …
1.3.6.1.4.1.232.3.2.6.1.1.5ColumncpqDaPhyDrvThrHardReadErrsread-onlymandatoryHard Read Errors Maximum Threshold. This shows the maximum threshold of read errors on a drive that could not be recovered by a physical drive`s Error Correcti…
1.3.6.1.4.1.232.3.2.6.1.1.6ColumncpqDaPhyDrvThrRecvReadErrsread-onlymandatoryRecovered Read Errors Maximum Threshold. This shows the maximum threshold of read errors corrected through physical drive retries during the reference time (ph…
1.3.6.1.4.1.232.3.2.6.1.1.7ColumncpqDaPhyDrvThrHardWriteErrsread-onlymandatoryHard Write Errors Maximum Threshold. This shows the maximum threshold of write errors that could not be recovered by a physical drive during the reference time…
1.3.6.1.4.1.232.3.2.6.1.1.8ColumncpqDaPhyDrvThrRecvWriteErrsread-onlymandatoryRecovered Write Errors Maximum Threshold. This shows the maximum threshold of write errors corrected through physical drive retries or recovered by a physical …
1.3.6.1.4.1.232.3.2.6.1.1.9ColumncpqDaPhyDrvThrHSeekErrsread-onlymandatorySeek Errors Maximum Threshold (high). The cpqDaphyDrvThrHSeekErrs and the cpqDaphyDrvThrSeekErrs together show the maximum threshold of total number of times t…
1.3.6.1.4.1.232.3.2.6.1.1.10ColumncpqDaPhyDrvThrSeekErrsread-onlymandatorySeek Errors Maximum Threshold (low). The cpqDaphyDrvThrHSeekErrs and the cpqDaphyDrvThrSeekErrs together show the maximum threshold of total number of times th…
1.3.6.1.4.1.232.3.2.6.1.1.11ColumncpqDaPhyDrvThrSpinupTimeread-onlymandatorySpin up Time Maximum Threshold in tenths of seconds. This shows the maximum of time it takes for a physical drive to spin up to full speed. This threshold is a…
1.3.6.1.4.1.232.3.2.6.1.1.12ColumncpqDaPhyDrvThrFunctTest1read-onlydeprecatedFunctional Test 1 Minimum Threshold. This provides the minimum threshold for information about a series of tests that indicate how well a physical drive works.…
1.3.6.1.4.1.232.3.2.6.1.1.13ColumncpqDaPhyDrvThrFunctTest2read-onlydeprecatedFunctional Test 2 Minimum Threshold. This provides the minimum threshold for information about a series of tests that indicate how well a physical drive works.…
1.3.6.1.4.1.232.3.2.6.1.1.14ColumncpqDaPhyDrvThrFunctTest3read-onlydeprecatedFunctional Test 3 Minimum Threshold. This provides the minimum threshold for information about a series of tests that indicate how well a physical drive works.…
1.3.6.1.4.1.232.3.2.6.1.1.15ColumncpqDaPhyDrvThrDrqTimeoutsread-onlymandatoryDRQ Timeouts Maximum Threshold. This shows the maximum threshold of the number of times that a physical drive continued to request data, but did not get a comm…
1.3.6.1.4.1.232.3.2.6.1.1.16ColumncpqDaPhyDrvThrOtherTimeoutsread-onlymandatoryOther Timeouts Maximum Threshold. This shows the maximum threshold of the number of times that a physical drive did not respond with an interrupt within a cont…
1.3.6.1.4.1.232.3.2.6.1.1.17ColumncpqDaPhyDrvThrSpinupRetriesread-onlymandatorySpin up Retries Maximum Threshold. This shows the maximum threshold of the number of times that a physical drive had to retry to spin up before successfully ac…
1.3.6.1.4.1.232.3.2.6.1.1.18ColumncpqDaPhyDrvThrBadRecvReadsread-onlymandatoryRecovery Failed (Bad) Read Error Maximum Threshold. This shows the maximum threshold of the number of times a read error occurred while performing Automatic Da…
1.3.6.1.4.1.232.3.2.6.1.1.19ColumncpqDaPhyDrvThrBadRecvWritesread-onlymandatoryRecovery Failed (Bad) Write Error Maximum Threshold. This shows the maximum threshold of the number of times a write error occurred while performing Automatic …
1.3.6.1.4.1.232.3.2.6.1.1.20ColumncpqDaPhyDrvThrFormatErrsread-onlymandatoryFormat Error Maximum Threshold. This shows the maximum threshold of the number of times a format operation failed when the controller attempted to remap a bad …
1.3.6.1.4.1.232.3.2.6.1.1.21ColumncpqDaPhyDrvThrPostErrsread-onlymandatoryPower On Self Test (Post) Error Maximum Threshold. This shows the maximum threshold of the number of times that a physical drive failed its self test during th…
1.3.6.1.4.1.232.3.2.6.1.1.22ColumncpqDaPhyDrvThrNotReadyErrsread-onlymandatoryDrive Not Ready Errors Maximum Threshold. This shows the maximum threshold of the number of times the physical drive failed after the spin up command was issue…
1.3.6.1.4.1.232.3.2.6.1.1.23ColumncpqDaPhyDrvThrReallocAbortsread-onlymandatoryPhysical Drive Reallocation Aborts Maximum Threshold. This shows the maximum threshold of the number of times the physical drive has failed due to an error tha…
1.3.6.1.4.1.232.3.2.6.1.1.24ColumncpqDaPhyDrvThrHotPlugsread-onlymandatoryPhysical Drive Hot Plug Count Maximum Threshold. This shows the maximum threshold of the number of times this physical drive can be hot-plugged (removed) from …
1.3.6.1.4.1.232.3.2.6.1.1.25ColumncpqDaPhyDrvThrMediaErrsread-onlymandatoryPhysical Drive Media Failure Count Maximum Threshold. This shows the maximum threshold of the number of times this physical drive can be failed due to unrecove…
1.3.6.1.4.1.232.3.2.6.1.1.26ColumncpqDaPhyDrvThrHardwareErrsread-onlymandatoryPhysical Drive Hardware Error Count Maximum Threshold. This shows the maximum threshold of the number of times this physical drive can return a bad hardware st…
1.3.6.1.4.1.232.3.2.6.1.1.27ColumncpqDaPhyDrvThrAbortedCmdsread-onlymandatoryPhysical Drive Aborted Command Failures Maximum Threshold. This shows the maximum threshold of the number of times this physical drive can be failed due to abo…
1.3.6.1.4.1.232.3.2.6.1.1.28ColumncpqDaPhyDrvThrSpinUpErrsread-onlymandatoryPhysical Drive Spin-Up Failure Count Maximum Threshold. This shows the maximum threshold of the number of times this physical drive was failed due to a failure…
1.3.6.1.4.1.232.3.2.6.1.1.29ColumncpqDaPhyDrvThrBadTargetErrsread-onlymandatoryPhysical Drive Bad Target Count Maximum Threshold. This shows the maximum threshold of the number of times this physical drive can perform some action that did…
1.3.6.1.4.1.232.3.2.6.1.1.30ColumncpqDaPhyDrvThrViUsedReallocsread-onlymandatoryUsed Reallocated Sectors Threshold Has Been Violated. This is used to indicate whether the number of used sectors of the reallocation area for a physical drive…
1.3.6.1.4.1.232.3.2.6.1.1.31ColumncpqDaPhyDrvThrViSpinupTimeread-onlymandatorySpin up Time in tenths of seconds Threshold Has Been Violated. This is used to indicate whether the time it took for a physical drive to spin up to full speed …
1.3.6.1.4.1.232.3.2.6.1.1.32ColumncpqDaPhyDrvThrViFunctTest1read-onlymandatoryFunctional Test 1 Threshold Has Been Violated. This is used to indicate whether the percentage value returned from Functional Test 1 has every dropped below th…
1.3.6.1.4.1.232.3.2.6.1.1.33ColumncpqDaPhyDrvThrViFunctTest2read-onlymandatoryFunctional Test 2 Threshold Has Been Violated. This is used to indicate whether the percentage value returned from Functional Test 2 has every dropped below th…
1.3.6.1.4.1.232.3.2.6.1.1.34ColumncpqDaPhyDrvThrViFunctTest3read-onlymandatoryFunctional Test 3 Threshold Has Been Violated. This is used to indicate whether the percentage value returned from Functional Test 3 has every dropped below th…
1.3.6.1.4.1.232.3.2.6.1.1.35ColumncpqDaPhyDrvThrBusFaultsread-onlymandatoryPhysical Drive Bus Fault Count Maximum Threshold. This shows the maximum threshold of the number of times this physical drive can return a bus fault status. Th…
1.3.6.1.4.1.232.3.2.6.1.1.36ColumncpqDaPhyDrvThrIrqDeglitchesread-onlymandatoryPhysical Drive IRQ Deglitch Count Maximum Threshold. This shows the maximum threshold of the number of times this physical drive can return a IRQ deglitch stat…
1.3.6.1.4.1.232.3.2.7NodecpqDaCntlrPerf
1.3.6.1.4.1.232.3.2.7.1TablecpqDaCntlrPerfTablenot-accessiblemandatoryDrive Array Controller Performance Monitor Table. A table of controller entries supporting the performance monitor information.
1.3.6.1.4.1.232.3.2.7.1.1RowcpqDaCntlrPerfEntrynot-accessiblemandatoryDrive Array Controller Performance Monitor Entry. A performance monitor entry.
1.3.6.1.4.1.232.3.2.7.1.1.1ColumncpqDaCntlrPerfCntlrIndexread-onlymandatoryDrive Array Controller Performance Monitor Controller Index. This maps the performance monitor information into their respective controllers which support perf…
1.3.6.1.4.1.232.3.2.7.1.1.2ColumncpqDaCntlrPerfInstanceread-onlymandatoryDrive Array Controller Performance Monitor Instance Index. This maps the performance monitor information for a specific controller and sample interval to contr…
1.3.6.1.4.1.232.3.2.7.1.1.3ColumncpqDaCntlrPerfSampleIntervalread-onlymandatoryArray Controller Performance Monitor Sample Interval. This value indicates the length of the performance interval for this controller and all logical volumes a…
1.3.6.1.4.1.232.3.2.7.1.1.4ColumncpqDaCntlrPerfVersionread-onlymandatoryArray Controller Performance Monitor Version. This value specifies the version of the performance monitor interface.
1.3.6.1.4.1.232.3.2.7.1.1.5ColumncpqDaCntlrPerfCpuPercentBusyread-onlymandatoryArray Controller Performance Monitor Cpu Percent Busy. This value specifies the total CPU percent busy as a number from 0 to 100 inclusive. If the value cannot…
1.3.6.1.4.1.232.3.2.7.1.1.6ColumncpqDaCntlrPerfCommandCountread-onlymandatoryArray Controller Performance Monitor Command Count. This value shows the total number of read and write commands processed in this sample. This value is expres…
1.3.6.1.4.1.232.3.2.7.1.1.7ColumncpqDaCntlrPerfAvgLatencyread-onlymandatoryArray Controller Performance Monitor Average Command Latency. This value shows the average command latency for this sample in 1/100,000 second units.
1.3.6.1.4.1.232.3.2.8NodecpqDaLogDrvPerf
1.3.6.1.4.1.232.3.2.8.1TablecpqDaLogDrvPerfTablenot-accessiblemandatoryDrive Array Logical Drive Performance Monitor Table. A table of logical drive entries supporting the performance monitor information.
1.3.6.1.4.1.232.3.2.8.1.1RowcpqDaLogDrvPerfEntrynot-accessiblemandatoryDrive Array Logical Drive Performance Monitor Entry. A performance monitor entry.
1.3.6.1.4.1.232.3.2.8.1.1.1ColumncpqDaLogDrvPerfCntlrIndexread-onlymandatoryDrive Array Logical Drive Performance Monitor Controller Index. This maps the performance monitor information into their respective controllers which support p…
1.3.6.1.4.1.232.3.2.8.1.1.2ColumncpqDaLogDrvPerfIndexread-onlymandatoryDrive Array Logical Drive Performance Monitor Drive Index. This maps the performance monitor information into their respective logical drives which support per…
1.3.6.1.4.1.232.3.2.8.1.1.3ColumncpqDaLogDrvPerfInstanceread-onlymandatoryDrive Array Logical Drive Performance Monitor Instance Index. This maps the performance monitor information for a specific controller, logical drive and sample…
1.3.6.1.4.1.232.3.2.8.1.1.4ColumncpqDaLogDrvPerfSampleIntervalread-onlymandatoryArray Logical Drive Performance Monitor Sample Interval. This value indicates the length of the performance interval for this controller and all logical volume…
1.3.6.1.4.1.232.3.2.8.1.1.5ColumncpqDaLogDrvPerfAvgQueueDepthread-onlymandatoryArray Logical Drive Performance Monitor Average Queue Depth. This value indicates the average command queue depth of the logical volume.
1.3.6.1.4.1.232.3.2.8.1.1.6ColumncpqDaLogDrvPerfReadsread-onlymandatoryArray Logical Drive Performance Monitor Reads. This value is the count of read requests for the logical volume expressed in reads per second.
1.3.6.1.4.1.232.3.2.8.1.1.7ColumncpqDaLogDrvPerfWritesread-onlymandatoryArray Logical Drive Performance Monitor Writes. This value is the count of write requests for the logical volume expressed in writes per second.
1.3.6.1.4.1.232.3.2.8.1.1.8ColumncpqDaLogDrvPerfTotalIOread-onlymandatoryArray Logical Drive Performance Monitor Total I/O. This value shows the total number of read and write requests for the logical volume expressed in reads and w…
1.3.6.1.4.1.232.3.2.8.1.1.9ColumncpqDaLogDrvPerfCacheHitsread-onlymandatoryArray Logical Drive Performance Monitor Cache Hits. This value shows the total number of read cache hits for the logical volume. This value is expressed in cac…
1.3.6.1.4.1.232.3.2.8.1.1.10ColumncpqDaLogDrvPerfCacheMissesread-onlymandatoryArray Logical Drive Performance Monitor Cache Misses. This value shows the total number of read cache misses for the logical volume. This value is expressed in…
1.3.6.1.4.1.232.3.2.8.1.1.11ColumncpqDaLogDrvPerfReadAheadSectorsread-onlymandatoryArray Logical Drive Performance Monitor Read Ahead Sectors. This value shows the total number read ahead sectors pre-fetched for the logical volume for this in…
1.3.6.1.4.1.232.3.2.8.1.1.12ColumncpqDaLogDrvPerfSectorsReadread-onlymandatoryArray Logical Drive Performance Monitor Sectors Read. This value shows the number of sectors read for the logical volume for this interval. This value is expre…
1.3.6.1.4.1.232.3.2.8.1.1.13ColumncpqDaLogDrvPerfSectorsWrittenread-onlymandatoryArray Logical Drive Performance Monitor Sectors Written. This value shows the number of sectors written for the logical volume for this interval. This value is…
1.3.6.1.4.1.232.3.2.9NodecpqDaTapeDrv
1.3.6.1.4.1.232.3.2.9.1TablecpqDaTapeDrvTablenot-accessiblemandatoryDrive Array Tape Drive Table. A table of tape drive entries.
1.3.6.1.4.1.232.3.2.9.1.1RowcpqDaTapeDrvEntrynot-accessiblemandatoryDrive Array Tape Drive Entry. A tape drive entry.
1.3.6.1.4.1.232.3.2.9.1.1.1ColumncpqDaTapeDrvCntlrIndexread-onlymandatoryDrive Array Tape Drive Controller Index. This index maps the tape drive back to the controller to which it is attached. The value of this index is the same as …
1.3.6.1.4.1.232.3.2.9.1.1.2ColumncpqDaTapeDrvBusIndexread-onlymandatoryDrive Array Tape Drive SCSI Bus Index. This is the controller SCSI bus to which the tape drive is attached.
1.3.6.1.4.1.232.3.2.9.1.1.3ColumncpqDaTapeDrvScsiIdIndexread-onlymandatoryDrive Array Tape Drive SCSI Index. This is the SCSI Target Id of the tape drive.
1.3.6.1.4.1.232.3.2.9.1.1.4ColumncpqDaTapeDrvLunIndexread-onlymandatoryDrive Array Tape Drive Logical Unit Number Index. This is the logical unit number of the tape drive.
1.3.6.1.4.1.232.3.2.9.1.1.5ColumncpqDaTapeDrvNameread-onlymandatoryDrive Array Tape Drive Model Name. This is the model name of the tape drive. It can be used for identification purposes.
1.3.6.1.4.1.232.3.2.9.1.1.6ColumncpqDaTapeDrvSerialNumberread-onlymandatoryDrive Array Tape Drive Serial Number. This is the unit serial number for the tape drive. It can be used for identification purposes.
1.3.6.1.4.1.232.3.2.9.1.1.7ColumncpqDaTapeDrvFwRevread-onlymandatoryDrive Array Tape Drive Firmware Revision. This is firmware revision level of the tape drive. It can be used for identification purposes.
1.3.6.1.4.1.232.3.2.9.1.1.8ColumncpqDaTapeDrvStatusread-onlymandatoryDrive Array Tape Drive Status. The tape drive can be in one of the following states: other(1) The tape drive is in a state other than one of those listed below…
1.3.6.1.4.1.232.3.2.9.1.1.9ColumncpqDaTapeDrvConditionread-onlymandatoryDrive Array Tape Drive Condition. This value represents the overall condition of the tape drive.
1.3.6.1.4.1.232.3.2.9.1.1.10ColumncpqDaTapeDrvFwSubtyperead-onlymandatoryDrive Array Tape Drive Firmware Subtype. This is used to differentiate the firmware versions which have the same tape drive type (as specified by cpqDaTapeDrvT…
1.3.6.1.4.1.232.3.2.9.1.1.11ColumncpqDaTapeDrvTyperead-onlymandatoryDrive Array Tape Drive Type. This is the drives model, and can be used for identification purposes. The following values are defined: other(1) The management a…
1.3.6.1.4.1.232.3.2.9.1.1.12ColumncpqDaTapeDrvCleanReqread-onlymandatoryDrive Array Tape Drive Cleaning Required. This is an indication of whether the tape drive heads require a cleaning session to occur. If this variable indicates…
1.3.6.1.4.1.232.3.2.9.1.1.13ColumncpqDaTapeDrvCleanTapeReplread-onlymandatoryDrive Array Tape Drive Cleaning Tape Replacement. This variable is only applicable to autoloader tape drives. This variable indicates whether the cleaning tape…
1.3.6.1.4.1.232.3.2.9.1.1.14ColumncpqDaTapeDrvCleanTapeCountread-onlymandatoryDrive Array Tape Drive Cleaning Tape Count. This variable is a count from a tape drive of the number of cleanings done by the tape cleaner last in the drive.
1.3.6.1.4.1.232.3.2.9.1.1.15ColumncpqDaTapeDrvLibraryDriveread-onlymandatoryDrive Array Tape Drive Library Drive. This variable indicates whether or not the tape drive is part of a tape library. It can be in one of the following states…
1.3.6.1.4.1.232.3.2.9.1.1.16ColumncpqDaTapeDrvMagSizeread-onlymandatoryTape Physical Drive Magazine Size. This variable indicates the number of tape slots available in the tape autoloader magazine cartridge that is currently loade…
1.3.6.1.4.1.232.3.2.9.1.1.17ColumncpqDaTapeDrvHotPlugread-onlymandatoryDrive Array Tape Drive Hot Plug Support Status. The following values are defined: other(1) The agent is unable to determine if this drive supports hot plug rep…
1.3.6.1.4.1.232.3.2.9.1.1.18ColumncpqDaTapeDrvPlacementread-onlymandatoryDrive Array Tape Drive Placement. The following values are defined: other(1) The agent is unable to determine if the tape drive is internal or external to the …
1.3.6.1.4.1.232.3.2.9.1.1.19ColumncpqDaTapeDrvCurrentWidthread-onlymandatoryDrive Array Tape Drive Current Width. The following values are defined: other(1) The agent is unable to determine the current negotiated data transfer width fo…
1.3.6.1.4.1.232.3.2.9.1.1.20ColumncpqDaTapeDrvCurrentSpeedread-onlymandatoryDrive Array Tape Drive Current Data Transfer Speed. The following values are defined: other(1) The agent is unable to determine the current negotiated data tra…
1.3.6.1.4.1.232.3.2.9.1.1.21ColumncpqDaTapeDrvProtocolread-onlymandatoryDrive Array Tape Drive Protocol. The following values are defined: other(1) The agent is unable to determine the protocol for this drive. parallelScsi(2) The d…
1.3.6.1.4.1.232.3.2.9.1.1.22ColumncpqDaTapeDrvNegotiatedLinkRateread-onlymandatoryDrive Array Tape Drive Negotiated Link Rate. The following values are defined: other(1) The agent is unable to determine the negotiated link rate this drive. r…
1.3.6.1.4.1.232.3.2.10NodecpqDaTapeCounters
1.3.6.1.4.1.232.3.2.10.1TablecpqDaTapeCountersTablenot-accessiblemandatoryDrive Array Tape Counters Table.
1.3.6.1.4.1.232.3.2.10.1.1RowcpqDaTapeCountersEntrynot-accessiblemandatoryDrive Array Tape Counters Entry.
1.3.6.1.4.1.232.3.2.10.1.1.1ColumncpqDaTapeCountersCntlrIndexread-onlymandatoryDrive Array Tape Counters Controller Index. This index maps the tape drive back to the controller to which it is attached. The value of this index is the same …
1.3.6.1.4.1.232.3.2.10.1.1.2ColumncpqDaTapeCountersBusIndexread-onlymandatoryDrive Array Tape Counters Scsi Bus Index. This is the controller SCSI bus to which the tape drive is attached.
1.3.6.1.4.1.232.3.2.10.1.1.3ColumncpqDaTapeCountersScsiIdIndexread-onlymandatoryDrive Array Tape Counters SCSI Index. This is the SCSI Target Id of the tape drive.
1.3.6.1.4.1.232.3.2.10.1.1.4ColumncpqDaTapeCountersLunIndexread-onlymandatoryDrive Array Tape Counters Logical Unit Number Index. This is the logical unit number of the tape drive.
1.3.6.1.4.1.232.3.2.10.1.1.5ColumncpqDaTapeCountersReWritesread-onlymandatoryTape Device Re-write count. This is the number of times blocks had to be re-written to the device. This value is maintained since the Tape Hardware Interface d…
1.3.6.1.4.1.232.3.2.10.1.1.6ColumncpqDaTapeCountersReReadsread-onlymandatoryTape Device Re-read count. This is the number of times blocks had to be re-read from the device. This value is maintained since the Tape Hardware Interface dri…
1.3.6.1.4.1.232.3.2.10.1.1.7ColumncpqDaTapeCountersTotalErrorsread-onlymandatoryTape Device Total Errors. This is the total number of read/write errors encountered. This value is maintained since the Tape Hardware Interface driver was load…
1.3.6.1.4.1.232.3.2.10.1.1.8ColumncpqDaTapeCountersTotalUncorrectableread-onlymandatoryTape Device Total Uncorrectable Errors. This is the total number of read and write errors which could not be corrected. This value is maintained since the Tape…
1.3.6.1.4.1.232.3.2.10.1.1.9ColumncpqDaTapeCountersTotalBytesread-onlymandatoryTape Device Total Bytes. This is the number total number of bytes read/written to the tape currently installed in the device. This value is reset whenever a ne…
1.3.6.1.4.1.232.3.2.11NodecpqDaTapeLibrary
1.3.6.1.4.1.232.3.2.11.1TablecpqDaTapeLibraryTablenot-accessiblemandatoryDrive Array Tape Library Table.
1.3.6.1.4.1.232.3.2.11.1.1RowcpqDaTapeLibraryEntrynot-accessiblemandatoryDrive Array Tape Library Entry.
1.3.6.1.4.1.232.3.2.11.1.1.1ColumncpqDaTapeLibraryCntlrIndexread-onlymandatoryDrive Array Tape Library Controller Index. This index maps the tape library back to the controller to which it is attached. The value of this index is the same…
1.3.6.1.4.1.232.3.2.11.1.1.2ColumncpqDaTapeLibraryScsiBusread-onlymandatoryDrive Array Tape Library Scsi Bus. The bus index indicates to which SCSI bus instance on a controller this table entry belongs. The instances start at one and …
1.3.6.1.4.1.232.3.2.11.1.1.3ColumncpqDaTapeLibraryScsiTargetread-onlymandatoryDrive Array Tape Library Scsi Target. The target index indicates to which SCSI ID on a controller SCSI bus this table entry belongs.
1.3.6.1.4.1.232.3.2.11.1.1.4ColumncpqDaTapeLibraryScsiLunread-onlymandatoryDrive Array Tape Library Scsi Lun. The Lun index indicates to which logical unit on a SCSI ID on a controller SCSI bus this table entry belongs.
1.3.6.1.4.1.232.3.2.11.1.1.5ColumncpqDaTapeLibrarySerialNumberread-onlymandatoryDrive Array Tape Library Serial Number. This is the unit serial number for the tape library. It can be used for identification purposes.
1.3.6.1.4.1.232.3.2.11.1.1.6ColumncpqDaTapeLibraryModelread-onlymandatoryDrive Array Tape Library Model. This is the model name of the tape library. It can be used for identification purposes.
1.3.6.1.4.1.232.3.2.11.1.1.7ColumncpqDaTapeLibraryFWRevread-onlymandatoryDrive Array Tape Library Serial Number. This is firmware revision level of the tape library. It can be used for identification purposes.
1.3.6.1.4.1.232.3.2.11.1.1.8ColumncpqDaTapeLibraryStatusread-onlymandatoryDrive Array Tape Library Status. The library can be in one of the following states: other(1) The library is in a state other than one of those listed below. ok…
1.3.6.1.4.1.232.3.2.11.1.1.9ColumncpqDaTapeLibraryDoorStatusread-onlymandatoryDrive Array Tape Library Door Status. The door can be in one of the following states: other(1) The door is in a state other than one of those listed below. not…
1.3.6.1.4.1.232.3.2.11.1.1.10ColumncpqDaTapeLibraryConditionread-onlymandatoryDrive Array Tape Library Condition. This value represents the overall condition of the tape library.
1.3.6.1.4.1.232.3.2.11.1.1.11ColumncpqDaTapeLibraryOverallConditionread-onlymandatoryDrive Array Tape Library Overall Condition. This value represents the overall condition of the tape library and any associated tape drives.
1.3.6.1.4.1.232.3.2.11.1.1.12ColumncpqDaTapeLibraryLastErrorread-onlydeprecatedDrive Array Tape Library Last Error. This is the last error returned by the tape library.
1.3.6.1.4.1.232.3.2.11.1.1.13ColumncpqDaTapeLibraryStatHoursread-onlymandatoryDrive Array Tape Library Stat Hours. This is the number of hours of operation for the library.
1.3.6.1.4.1.232.3.2.11.1.1.14ColumncpqDaTapeLibraryStatMovesread-onlymandatoryDrive Array Tape Library Stat Moves. This is the number of tape moves for the library loader arm.
1.3.6.1.4.1.232.3.2.11.1.1.15ColumncpqDaTapeLibraryDriveListread-onlydeprecatedDrive Array Tape Library Tape Drive List. This is a data structure containing the list of tape drive ids that are present in this library. The format is: field…
1.3.6.1.4.1.232.3.2.11.1.1.16ColumncpqDaTapeLibraryCurrentWidthread-onlymandatoryDrive Array Tape Library Current Width. The following values are defined: other(1) The agent is unable to determine the current negotiated data transfer width …
1.3.6.1.4.1.232.3.2.11.1.1.17ColumncpqDaTapeLibraryCurrentSpeedread-onlymandatoryDrive Array Tape Library Current Data Transfer Speed. The following values are defined: other(1) The agent is unable to determine the current negotiated data t…
1.3.6.1.4.1.232.3.2.11.1.1.18ColumncpqDaTapeLibraryDriveList2read-onlymandatoryDrive Array Tape Library Tape Drive List 2. This is a data structure containing the list of tape drive ids that are present in this library. The format is: fie…
1.3.6.1.4.1.232.3.2.11.1.1.19ColumncpqDaTapeLibraryProtocolread-onlymandatoryDrive Array Tape Library Protocol. The following values are defined: other(1) The agent is unable to determine the protocol for this library. parallelScsi(2) T…
1.3.6.1.4.1.232.3.2.11.1.1.20ColumncpqDaTapeLibraryNegotiatedLinkRateread-onlymandatoryDrive Array Tape Library Negotiated Link Rate. The following values are defined: other(1) The agent is unable to determine the negotiated link rate for this li…
1.3.6.1.4.1.232.3.3NodecpqDaPhyDrvStatusChangePhysical Drive Status Change. This trap signifies that the agent has detected a change in the status of a drive array physical drive. The variable cpaDaPhyDrvS…
1.3.6.1.4.1.232.3.3NodecpqDaTrap
1.3.6.1.4.1.232.3.3.1ScalarcpqDaTrapPktsread-onlydeprecatedThe total number of trap packets issued by the drive array enterprise since the instrument agent was loaded.
1.3.6.1.4.1.232.3.3.2ScalarcpqDaTrapLogMaxSizeread-onlydeprecatedThe maximum number of entries that will currently be kept in the trap log. If the maximum size has been reached and a new trap occurs the oldest trap will be r…
1.3.6.1.4.1.232.3.3.3TablecpqDaTrapLogTablenot-accessibledeprecatedAn ordered list of trap log entries (conceptually a queue). The trap log entries will be kept in the order in which they were generated with the most recent tr…
1.3.6.1.4.1.232.3.3.3.1RowcpqDaTrapLogEntrynot-accessibledeprecatedA description of a trap event.
1.3.6.1.4.1.232.3.3.3.1.1ColumncpqDaTrapLogIndexread-onlydeprecatedThis value uniquely identifies this trapLogEntry at this time. The most recent trap will have an index of 1 and the oldest trap will have an index of trapLogMa…
1.3.6.1.4.1.232.3.3.3.1.2ColumncpqDaTrapTyperead-onlydeprecatedThe type of the trap event that this entry describes. This number refers to an entry in a list of traps enumerating the possible traps the Drive Array agent ma…
1.3.6.1.4.1.232.3.3.3.1.3ColumncpqDaTrapTimeread-onlydeprecatedThe time of the trap event that this entry describes. The time is given in year (first octet), month, day of month, hour, minute, second (last octet) order. Ea…
1.3.6.1.4.1.232.3.4NodecpqDaPhyDrvThreshPassedTrapPhysical Drive Threshold Passed. This trap signifies that the agent has detected a factory threshold associated with one of the physical drive objects on a dri…
1.3.6.1.4.1.232.3.5NodecpqDaAccelStatusChangeAccelerator Board Status Change. This trap signifies that the agent has detected a change in the cpqDaAccelStatus of an array accelerator write cache. The curr…
1.3.6.1.4.1.232.3.6NodecpqDaAccelBadDataTrapAccelerator Board Bad Data. This trap signifies that the agent has detected an array accelerator cache board that has lost battery power. If data was being sto…
1.3.6.1.4.1.232.3.7NodecpqDaAccelBatteryFailedAccelerator Board Battery Failed. This trap signifies that the agent has detected a battery failure associated with the array accelerator cache board. The curr…
1.3.6.1.4.1.232.3001NodecpqDa2LogDrvStatusChangeLogical Drive Status Change. This trap signifies that the agent has detected a change in the status of a drive array logical drive. The variable cpqDaLogDrvSta…
1.3.6.1.4.1.232.3002NodecpqDa2SpareStatusChangeSpare Drive Status Change. This trap signifies that the agent has detected a change in the status of a drive array spare drive. The variable cpqDaSpareStatus i…
1.3.6.1.4.1.232.3003NodecpqDa2PhyDrvStatusChangePhysical Drive Status Change. This trap signifies that the agent has detected a change in the status of a drive array physical drive. The variable cpaDaPhyDrvS…
1.3.6.1.4.1.232.3004NodecpqDa2PhyDrvThreshPassedTrapPhysical Drive Threshold Passed. This trap signifies that the agent has detected a factory threshold associated with one of the physical drive objects on a dri…
1.3.6.1.4.1.232.3005NodecpqDa2AccelStatusChangeAccelerator Board Status Change. This trap signifies that the Insight Agent has detected a change in the cpqDaAccelStatus of array accelerator cache. The curre…
1.3.6.1.4.1.232.3006NodecpqDa2AccelBadDataTrapAccelerator Board Bad Data. This trap signifies that the agent has detected an array accelerator cache board that has lost battery power. If data was being sto…
1.3.6.1.4.1.232.3007NodecpqDa2AccelBatteryFailedAccelerator Board Battery Failed. This trap signifies that the agent has detected a battery failure associated with the array accelerator cache board. The curr…
1.3.6.1.4.1.232.3008NodecpqDa3LogDrvStatusChangeLogical Drive Status Change. This trap signifies that the agent has detected a change in the status of a drive array logical drive. The variable cpqDaLogDrvSta…
1.3.6.1.4.1.232.3009NodecpqDa3SpareStatusChangeSpare Drive Status Change. This trap signifies that the agent has detected a change in the status of a drive array spare drive. The variable cpqDaSpareStatus i…
1.3.6.1.4.1.232.3010NodecpqDa3PhyDrvStatusChangePhysical Drive Status Change. This trap signifies that the agent has detected a change in the status of a drive array physical drive. The variable cpaDaPhyDrvS…
1.3.6.1.4.1.232.3011NodecpqDa3PhyDrvThreshPassedTrapPhysical Drive Threshold Passed. This trap signifies that the agent has detected a factory threshold associated with one of the physical drive objects on a dri…
1.3.6.1.4.1.232.3012NodecpqDa3AccelStatusChangeAccelerator Board Status Change. This trap signifies that the agent has detected a change in the cpqDaAccelStatus of an array accelerator cache board. The curr…
1.3.6.1.4.1.232.3013NodecpqDa3AccelBadDataTrapAccelerator Board Bad Data. This trap signifies that the agent has detected an array accelerator cache board that has lost battery power. If data was being sto…
1.3.6.1.4.1.232.3014NodecpqDa3AccelBatteryFailedAccelerator Board Battery Failed. This trap signifies that the agent has detected a battery failure associated with the array accelerator cache board. The curr…
1.3.6.1.4.1.232.3015NodecpqDaCntlrStatusChangeController Status Change. This trap signifies that the agent has detected a change in the status of a drive array controller. The variable cpqDaCntlrBoardStatu…
1.3.6.1.4.1.232.3016NodecpqDaCntlrActiveController Active. This trap signifies that the agent has detected that a backup array controller in a duplexed pair has switched over to the active role. The …
1.3.6.1.4.1.232.3017NodecpqDa4SpareStatusChangeSpare Drive Status Change. This trap signifies that the agent has detected a change in the status of a drive array spare drive. The variable cpqDaSpareStatus i…
1.3.6.1.4.1.232.3018NodecpqDa4PhyDrvStatusChangePhysical Drive Status Change. This trap signifies that the agent has detected a change in the status of a drive array physical drive. The variable cpaDaPhyDrvS…
1.3.6.1.4.1.232.3019NodecpqDa4PhyDrvThreshPassedTrapPhysical Drive Threshold Passed. This trap signifies that the agent has detected a factory threshold associated with one of the physical drive objects on a dri…
1.3.6.1.4.1.232.3020NodecpqDaTapeLibraryStatusChangeTape Library Status Change. This trap signifies that the agent has detected a change in the status of a tape library. The variable cpqDaTapeLibraryStatus indic…
1.3.6.1.4.1.232.3021NodecpqDaTapeLibraryDoorStatusChangeTape Library Door Status Change. This trap signifies that the agent has detected a change in the door status of a tape library. The variable cpqDaTapeLibraryDo…
1.3.6.1.4.1.232.3022NodecpqDaTapeDriveStatusChangeTape Drive Status Change. This trap signifies that the agent has detected a change in the status of a tape drive. The variable cpqDaTapeDrvStatus indicates the…
1.3.6.1.4.1.232.3023NodecpqDaTapeDriveCleaningRequiredTape Drive Cleaning Required trap. The agent has detected a tape drive that needs to have a cleaning tape inserted and run. This will cause the tape drive head…
1.3.6.1.4.1.232.3024NodecpqDaTapeDriveCleanTapeReplaceTape Drive Cleaning Tape Needs Replacing. The agent has detected that an autoloader tape unit has a cleaning tape that has been fully used and therefore needs …
1.3.6.1.4.1.232.3025NodecpqDa5AccelStatusChangeAccelerator Board Status Change. This trap signifies that the agent has detected a change in the status of an array accelerator cache board. The current status…
1.3.6.1.4.1.232.3026NodecpqDa5AccelBadDataTrapAccelerator Board Bad Data. This trap signifies that the agent has detected an array accelerator cache board that has lost battery power. If data was being sto…
1.3.6.1.4.1.232.3027NodecpqDa5AccelBatteryFailedAccelerator Board Battery Failed. This trap signifies that the agent has detected a battery failure associated with the array accelerator cache board. User Act…
1.3.6.1.4.1.232.3028NodecpqDa5CntlrStatusChangeController Status Change. This trap signifies that the agent has detected a change in the status of a drive array controller. The variable cpqDaCntlrBoardStatu…
1.3.6.1.4.1.232.3029NodecpqDa5PhyDrvStatusChangePhysical Drive Status Change. This trap signifies that the agent has detected a change in the status of a drive array physical drive. The variable cpaDaPhyDrvS…
1.3.6.1.4.1.232.3030NodecpqDa5PhyDrvThreshPassedTrapPhysical Drive Threshold Passed. This trap signifies that the agent has detected a factory threshold associated with one of the physical drive objects on a dri…
1.3.6.1.4.1.232.3031NodecpqDa2TapeLibraryStatusChangeTape Library Status Change. This trap signifies that the agent has detected a change in the status of a tape library. The variable cpqDaTapeLibraryStatus indic…
1.3.6.1.4.1.232.3032NodecpqDa2TapeDriveStatusChangeTape Drive Status Change. This trap signifies that the agent has detected a change in the status of a tape drive. The variable cpqDaTapeDrvStatus indicates the…
1.3.6.1.4.1.232.3033NodecpqDa6CntlrStatusChangeController Status Change. This trap signifies that the agent has detected a change in the status of a drive array controller. The variable cpqDaCntlrBoardStatu…
1.3.6.1.4.1.232.3034NodecpqDa6LogDrvStatusChangeLogical Drive Status Change. This trap signifies that the agent has detected a change in the status of a drive array logical drive. The variable cpqDaLogDrvSta…
1.3.6.1.4.1.232.3035NodecpqDa6SpareStatusChangeSpare Drive Status Change. This trap signifies that the agent has detected a change in the status of a drive array spare drive. The variable cpqDaSpareStatus i…
1.3.6.1.4.1.232.3036NodecpqDa6PhyDrvStatusChangePhysical Drive Status Change. This trap signifies that the agent has detected a change in the status of a drive array physical drive. The variable cpaDaPhyDrvS…
1.3.6.1.4.1.232.3037NodecpqDa6PhyDrvThreshPassedTrapPhysical Drive Threshold Passed. This trap signifies that the agent has detected a factory threshold associated with one of the physical drive objects on a dri…
1.3.6.1.4.1.232.3038NodecpqDa6AccelStatusChangeStorage - Controller Write Cache Status Changed. This trap signifies that the agent has detected a change in the status of a cache. The current status is repre…
1.3.6.1.4.1.232.3039NodecpqDa6AccelBadDataTrapStorage - Controller Write Cache Data Lost. This trap signifies that the agent has detected a controller cache module that has lost backup power. If data was b…
1.3.6.1.4.1.232.3040NodecpqDa6AccelBatteryFailedCache Module Board Backup Power Source Failed. This trap signifies that the agent has detected a backup power source failure associated with the cache module b…
1.3.6.1.4.1.232.3041NodecpqDa6TapeLibraryStatusChangeTape Library Status Change. This trap signifies that the agent has detected a change in the status of a tape library. The variable cpqDaTapeLibraryStatus indic…
1.3.6.1.4.1.232.3042NodecpqDa6TapeLibraryDoorStatusChangeTape Library Door Status Change. This trap signifies that the agent has detected a change in the door status of a tape library. The variable cpqDaTapeLibraryDo…
1.3.6.1.4.1.232.3043NodecpqDa6TapeDriveStatusChangeTape Drive Status Change. This trap signifies that the agent has detected a change in the status of a tape drive. The variable cpqDaTapeDrvStatus indicates the…
1.3.6.1.4.1.232.3044NodecpqDa6TapeDriveCleaningRequiredTape Drive Cleaning Required trap. The agent has detected a tape drive that needs to have a cleaning tape inserted and run. This will cause the tape drive head…
1.3.6.1.4.1.232.3045NodecpqDa6TapeDriveCleanTapeReplaceTape Drive Cleaning Tape Needs Replacing. The agent has detected that an autoloader tape unit has a cleaning tape that has been fully used and therefore needs …
1.3.6.1.4.1.232.3046NodecpqDa7PhyDrvStatusChangePhysical Drive Status Change. This trap signifies that the agent has detected a change in the status of a drive array physical drive. The variable cpaDaPhyDrvS…
1.3.6.1.4.1.232.3047NodecpqDa7SpareStatusChangeSpare Drive Status Change. This trap signifies that the agent has detected a change in the status of a drive array spare drive. The variable cpqDaSpareStatus i…
1.3.6.1.4.1.232.3048NodecpqDaCntlrPartnerStatusChangePartner Controller Status Change. This trap signifies that the agent has detected a change in the status of a drive array partner controller. The variable cpqD…
1.3.6.1.4.1.232.3049NodecpqDaPhyDrvSSDWearStatusChangeSolid State Disk Wear Status Change. This trap signifies that the agent has detected a change in the SSD wear status of a drive array physical drive. The varia…
1.3.6.1.4.1.232.3903NodecpqDaSmartArraySecureEraseFailedSecure Erase of Smart Array has failed.