CPQN54NN-MIB
27 objects
No module-level DESCRIPTION found.
Imported Objects
| RFC-1212 | OBJECT-TYPE |
| RFC-1215 | TRAP-TYPE |
| RFC1155-SMI | enterprises |
| RFC1213-MIB | sysDescr sysUpTime |
| OID | Name | Access | Status | Description |
|---|---|---|---|---|
| 1.3.6.1.4.1.232 | Nodecompaq | |||
| 1.3.6.1.4.1.232.111 | NodecpqGigaSwitch | |||
| 1.3.6.1.4.1.232.111.1 | NodecpqGigaSwitchProd | |||
| 1.3.6.1.4.1.232.111.1.1 | NodecpqGigaSwitchId5422 | |||
| 1.3.6.1.4.1.232.111.1.2 | NodecpqGigaSwitchId5411 | |||
| 1.3.6.1.4.1.232.111.2 | NodecpqOids | |||
| 1.3.6.1.4.1.232.111.2.1 | NodecpqMauType | |||
| 1.3.6.1.4.1.232.111.2.1.1 | NodecpqMauType1000BaseSX | |||
| 1.3.6.1.4.1.232.111.2.1.2 | NodecpqMauType1000BaseLX | |||
| 1.3.6.1.4.1.232.111.2.1.3 | NodecpqMauType1000BaseCX | |||
| 1.3.6.1.4.1.232.111.2.1.4 | NodecpqMauType1000BaseSXFD | |||
| 1.3.6.1.4.1.232.111.2.1.5 | NodecpqMauType1000BaseLXFD | |||
| 1.3.6.1.4.1.232.111.2.1.6 | NodecpqMauType1000BaseCXFD | |||
| 1.3.6.1.4.1.232.111.3 | NodecpqGigaSwitchMib | |||
| 1.3.6.1.4.1.232.111.3.1 | NodecpqGigaSwitchSystem | |||
| 1.3.6.1.4.1.232.111.3.1.3 | ScalarcpqSaveConfiguration | write-only | mandatory | When this object is set, the device will copy the contents of the configuration database to a buffer and save it to the persistant store specified by the value… |
| 1.3.6.1.4.1.232.111.3.1.4 | ScalarcpqSaveStatus | read-only | mandatory | This object will return the status of a save operation invoked by setting the cpqSaveConfiguration object. A network management application can read this objec… |
| 1.3.6.1.4.1.232.111.3.1.5 | ScalarcpqCurrentConfigInUse | read-only | mandatory | Shows which configuration store was used at last boot |
| 1.3.6.1.4.1.232.111.3.1.6 | ScalarcpqConfigToUseOnReboot | read-write | mandatory | Controls which configuration store will be used on next reboot. |
| 1.3.6.1.4.1.232.111.6 | Nodeoverheat | A overheat trap indicates that the on board tempature sensor has reported a overheat condition. System will shutdown until unit has sufficiently cooled such th… | ||
| 1.3.6.1.4.1.232.111.7 | Nodefanfailed | A fan failed trap indicates one or more of the cooling fans inside the device has failed. A fanOK trap will be sent once the fan has attained normal operation. | ||
| 1.3.6.1.4.1.232.111.8 | NodefanOK | A fan has transitioned out of a failure state and is now operating correctly. | ||
| 1.3.6.1.4.1.232.111.9 | NodeinvalidLoginAttempt | A user attempted to login to console or by telnet but was refused access due to incorrect username or password | ||
| 1.3.6.1.4.1.232.111.10 | NodepowerSupplyFail | One or more sources of power to this agent has failed. Presumably a redundant power-supply has taken over. | ||
| 1.3.6.1.4.1.232.111.11 | NodepowerSupplyGood | One or more previously bad sources of power to this agent has come back to life without causing an agent restart. | ||
| 1.3.6.1.4.1.232.111.12 | NoderpsAlarm | Attached Redundant Power Supply device is indicating an alarm condition. | ||
| 1.3.6.1.4.1.232.111.13 | NoderpsNoAlarm | Attached Redundant Power Supply device is no longer indicating an alarm condition. |