MIB Viewer

CPQRACK-MIB

558 objects
No module-level DESCRIPTION found.
OIDNameAccessStatusDescription
1.3.6.1.4.1.232.22NodecpqRackInfo
1.3.6.1.4.1.232.22.1NodecpqRackMibRev
1.3.6.1.4.1.232.22.1.1ScalarcpqRackMibRevMajorread-onlymandatoryThe major revision level of the MIB. A change in the major revision level represents a major change in the architecture of the MIB. A change in the major revis…
1.3.6.1.4.1.232.22.1.2ScalarcpqRackMibRevMinorread-onlymandatoryThe minor revision level of the MIB. A change in the minor revision level may represent some minor additional support, no changes to any pre-existing informati…
1.3.6.1.4.1.232.22.1.3ScalarcpqRackMibConditionread-onlymandatoryThe overall condition. This object represents the overall status of the rack information represented by this MIB.
1.3.6.1.4.1.232.22.2NodecpqRackComponent
1.3.6.1.4.1.232.22.2.1NodecpqRackInterface
1.3.6.1.4.1.232.22.2.1.4NodecpqRackOsCommon
1.3.6.1.4.1.232.22.2.1.4.1ScalarcpqRackOsCommonPollFreqread-writemandatoryThe Management Agent's polling frequency. The frequency, in seconds, at which the Agent requests information from the device driver. A frequency of zero (0) in…
1.3.6.1.4.1.232.22.2.2NodecpqRackAsset
1.3.6.1.4.1.232.22.2.2.1TablecpqRackAssetTablenot-accessiblemandatoryA table of rack asset information.
1.3.6.1.4.1.232.22.2.2.1.1RowcpqRackAssetEntrynot-accessiblemandatoryA rack asset description.
1.3.6.1.4.1.232.22.2.2.1.1.1ColumncpqRackAssetIndexread-onlymandatoryA number that uniquely specifies this rack table entry.
1.3.6.1.4.1.232.22.2.2.1.1.2ColumncpqRackNameread-onlymandatoryThe customer changeable identifier used to identify the entire rack. The string will be empty if the system does not report this function.
1.3.6.1.4.1.232.22.2.2.1.1.3ColumncpqRackUidread-onlymandatoryThe rack unique identifier. The string will be empty if the rack does not report the UID or if it could not be determined.
1.3.6.1.4.1.232.22.2.2.1.1.4ColumncpqRackSerialNumread-onlymandatoryThe rack serial number. The string will be empty if the rack does not report the serial number.
1.3.6.1.4.1.232.22.2.2.1.1.5ColumncpqRackTrapSequenceNumread-onlymandatoryThe trap sequence number for rack traps. This is used by the management application trap processing. This will be -1 if the rack does not report the informatio…
1.3.6.1.4.1.232.22.2.2.1.1.6ColumncpqRackHeightread-onlymandatoryThe internal height dimension of the useable rack space expressed in millimeters. This will be -1 if the rack does not report the information or it could not b…
1.3.6.1.4.1.232.22.2.2.1.1.7ColumncpqRackWidthread-onlymandatoryThe internal width dimension of the useable rack space expressed in millimeters. This will be -1 if the rack does not report the information or it could not be…
1.3.6.1.4.1.232.22.2.2.1.1.8ColumncpqRackDepthread-onlymandatoryThe internal depth dimension of the useable rack space expressed in millimeters. This will be -1 if the rack does not report the information or it could not be…
1.3.6.1.4.1.232.22.2.3NodecpqRackEnclosure
1.3.6.1.4.1.232.22.2.3.1NodecpqRackCommonEnclosure
1.3.6.1.4.1.232.22.2.3.1.1TablecpqRackCommonEnclosureTablenot-accessiblemandatoryA table of rack enclosure information.
1.3.6.1.4.1.232.22.2.3.1.1.1RowcpqRackCommonEnclosureEntrynot-accessiblemandatoryA rack enclosure description.
1.3.6.1.4.1.232.22.2.3.1.1.1.1ColumncpqRackCommonEnclosureRackread-onlymandatoryA number that uniquely specifies this rack.
1.3.6.1.4.1.232.22.2.3.1.1.1.2ColumncpqRackCommonEnclosureIndexread-onlymandatoryA number that uniquely specifies this enclosure in the rack.
1.3.6.1.4.1.232.22.2.3.1.1.1.3ColumncpqRackCommonEnclosureModelread-onlymandatoryThe model name of the enclosure. The string will be empty if the enclosure does not report the model information.
1.3.6.1.4.1.232.22.2.3.1.1.1.4ColumncpqRackCommonEnclosureAssetTagread-onlymandatoryThe customer changeable asset identifier of the enclosure. The string will be empty if the system does not report this function or if the asset tag has not bee…
1.3.6.1.4.1.232.22.2.3.1.1.1.5ColumncpqRackCommonEnclosurePartNumberread-onlymandatoryThe part number of the enclosure. The string will be empty if the enclosure does not report this function.
1.3.6.1.4.1.232.22.2.3.1.1.1.6ColumncpqRackCommonEnclosureSparePartNumberread-onlymandatoryThe spare part number of the enclosure. The string will be empty if the enclosure does not report this function.
1.3.6.1.4.1.232.22.2.3.1.1.1.7ColumncpqRackCommonEnclosureSerialNumread-onlymandatoryThe serial number of the enclosure. The string will be empty if the enclosure does not report the serial number.
1.3.6.1.4.1.232.22.2.3.1.1.1.8ColumncpqRackCommonEnclosureFWRevread-onlymandatoryThe firmware revision of the enclosure. The string will be empty if the enclosure does not report the firmware revision or does not contain firmware.
1.3.6.1.4.1.232.22.2.3.1.1.1.9ColumncpqRackCommonEnclosureNameread-onlymandatoryThe name of the enclosure. The string will be empty if the enclosure does not report the name or it could not be determined.
1.3.6.1.4.1.232.22.2.3.1.1.1.10ColumncpqRackCommonEnclosureNeighborNamePrevread-onlymandatoryThe name of the enclosure immediately preceding or above this enclosure. The string will be empty if the neighbor enclosure name could not be determined or the…
1.3.6.1.4.1.232.22.2.3.1.1.1.11ColumncpqRackCommonEnclosureNeighborNameNextread-onlymandatoryThe name of the enclosure immediately following or below this enclosure. The string will be empty if the neighbor enclosure name could not be determined or the…
1.3.6.1.4.1.232.22.2.3.1.1.1.12ColumncpqRackCommonEnclosureHeightread-onlymandatoryThe height dimension of the rack space taken by the enclosure expressed in millimeters. This will be -1 if the rack does not report the information or it could…
1.3.6.1.4.1.232.22.2.3.1.1.1.13ColumncpqRackCommonEnclosureWidthread-onlymandatoryThe width dimension of the rack space taken by the enclosure expressed in millimeters. This will be -1 if the rack does not report the information or it could …
1.3.6.1.4.1.232.22.2.3.1.1.1.14ColumncpqRackCommonEnclosureDepthread-onlymandatoryThe depth dimension of the rack space taken by the enclosure expressed in millimeters. This will be -1 if the rack does not report the information or it could …
1.3.6.1.4.1.232.22.2.3.1.1.1.15ColumncpqRackCommonEnclosureTrapSequenceNumread-onlymandatoryThe trap sequence number for the enclosure. This is used by the management application trap processing. This will be -1 if the rack does not report the informa…
1.3.6.1.4.1.232.22.2.3.1.1.1.16ColumncpqRackCommonEnclosureConditionread-onlymandatoryThe overall condition of the enclosure. This is the aggregate of the temperature sensors, fans, and fuses within the enclosure. This value will be one of the f…
1.3.6.1.4.1.232.22.2.3.1.1.1.17ColumncpqRackCommonEnclosureHasServerBladesread-onlymandatoryThe enclosure can contain server blades. This will be true(2) is the enclosure can house server blades. The cpqRackServerEnclosureTable will contain server enc…
1.3.6.1.4.1.232.22.2.3.1.1.1.18ColumncpqRackCommonEnclosureHasPowerSuppliesread-onlymandatoryThe enclosure can contain power supplies. This will be true(2) is the enclosure can house power supplies. The cpqRackEnclosurePowerTable will contain power enc…
1.3.6.1.4.1.232.22.2.3.1.1.1.19ColumncpqRackCommonEnclosureHasNetConnectorsread-onlymandatoryThe enclosure contains network connectivity. This will be true(2) is the enclosure contains network connectivity. The cpqRackCommonEnclosureNetConnectorTable w…
1.3.6.1.4.1.232.22.2.3.1.1.1.20ColumncpqRackCommonEnclosureHasTempSensorsread-onlymandatoryThe enclosure contains temperature sensors. This will be true(2) is the enclosure contains temperature sensors. The cpqRackCommonEnclosureTempTable will contai…
1.3.6.1.4.1.232.22.2.3.1.1.1.21ColumncpqRackCommonEnclosureHasFansread-onlymandatoryThe enclosure contains fans. This will be true(2) is the enclosure contains fans. The cpqRackCommonEnclosureFanTable will contain the fan specific information.…
1.3.6.1.4.1.232.22.2.3.1.1.1.22ColumncpqRackCommonEnclosureHasFusesread-onlymandatoryThe enclosure contains fuses. This will be true(2) is the enclosure contains fuses. The cpqRackCommonEnclosureFuseTable will contain the fuse specific informat…
1.3.6.1.4.1.232.22.2.3.1.1.1.23ColumncpqRackCommonEnclosureMgmtUIDread-writemandatoryThe Unit Identifier LED. This value will be one of the following: other(1) The state of the LED could not be determined. Setting the LED state is not allowed. …
1.3.6.1.4.1.232.22.2.3.1.1.1.24ColumncpqRackCommonEnclosureSerialNumPrevread-onlymandatoryThe serial number of the enclosure immediately preceding or above this enclosure. The string will be empty if the neighbor enclosure serial number could not be…
1.3.6.1.4.1.232.22.2.3.1.1.1.25ColumncpqRackCommonEnclosureSerialNumNextread-onlymandatoryThe serial number of the enclosure immediately following or below this enclosure. The string will be empty if the neighbor enclosure serial number could not be…
1.3.6.1.4.1.232.22.2.3.1.1.1.26ColumncpqRackCommonEnclosureAddressread-onlymandatoryThe unique address of the enclosure within the rack. This will be -1 if the rack does not report the information or it could not be determined.
1.3.6.1.4.1.232.22.2.3.1.1.1.27ColumncpqRackCommonEnclosureProductIdread-onlymandatoryThe product id string of the enclosure. The string will be empty if the enclosure does not report the product id string.
1.3.6.1.4.1.232.22.2.3.1.1.1.28ColumncpqRackCommonEnclosureProductIdPrevread-onlymandatoryThe product id string of the enclosure immediately preceding or above this enclosure. The string will be empty if the enclosure does not report the product id …
1.3.6.1.4.1.232.22.2.3.1.1.1.29ColumncpqRackCommonEnclosureProductIdNextread-onlymandatoryThe product id string of the enclosure immediately following or below this enclosure. The string will be empty if the enclosure does not report the product id …
1.3.6.1.4.1.232.22.2.3.1.1.1.30ColumncpqRackCommonEnclosureUUIDread-onlymandatoryThe universal unique identifier string of the enclosure. The string will be empty if the enclosure does not report the UUID string.
1.3.6.1.4.1.232.22.2.3.1.1.1.31ColumncpqRackCommonEnclosureUUIDPrevread-onlymandatoryThe universal unique identifier string of the enclosure immediately preceding or above this enclosure. The string will be empty if the enclosure does not repor…
1.3.6.1.4.1.232.22.2.3.1.1.1.32ColumncpqRackCommonEnclosureUUIDNextread-onlymandatoryThe universal unique identifier string of the enclosure immediately following or below this enclosure. The string will be empty if the enclosure does not repor…
1.3.6.1.4.1.232.22.2.3.1.1.1.33ColumncpqRackCommonEnclosureHasManagersread-onlymandatoryThe enclosure contains managers. This will be true(2) is the enclosure contains managers. The cpqRackCommonEnclosureManagerTable will contain the manager speci…
1.3.6.1.4.1.232.22.2.3.1.2TablecpqRackCommonEnclosureTempTablenot-accessiblemandatoryA table of rack enclosure temperature sensor information.
1.3.6.1.4.1.232.22.2.3.1.2.1RowcpqRackCommonEnclosureTempEntrynot-accessiblemandatoryA rack enclosure temperature sensor description.
1.3.6.1.4.1.232.22.2.3.1.2.1.1ColumncpqRackCommonEnclosureTempRackread-onlymandatoryA number that uniquely specifies this rack.
1.3.6.1.4.1.232.22.2.3.1.2.1.2ColumncpqRackCommonEnclosureTempChassisread-onlymandatoryA number that uniquely specifies this enclosure in the rack.
1.3.6.1.4.1.232.22.2.3.1.2.1.3ColumncpqRackCommonEnclosureTempSensorIndexread-onlymandatoryA number that uniquely specifies this temperature sensor within this enclosure in the rack.
1.3.6.1.4.1.232.22.2.3.1.2.1.4ColumncpqRackCommonEnclosureTempSensorEnclosureNameread-onlymandatoryThe name of the enclosure. The string will be empty if the enclosure does not report the name or it could not be determined.
1.3.6.1.4.1.232.22.2.3.1.2.1.5ColumncpqRackCommonEnclosureTempLocationread-onlymandatoryThe location description of the temperature sensor within the enclosure. The string will be empty if the location could not be determined.
1.3.6.1.4.1.232.22.2.3.1.2.1.6ColumncpqRackCommonEnclosureTempCurrentread-onlymandatoryThis is the current temperature sensor reading in degrees celsius. If this value cannot be determined by software, then a value of -1 will be returned.
1.3.6.1.4.1.232.22.2.3.1.2.1.7ColumncpqRackCommonEnclosureTempThresholdread-onlymandatoryThis is the threshold temperature sensor setting in degrees celsius. This is the temperature in which the sensor will be considered to be in a tripped state th…
1.3.6.1.4.1.232.22.2.3.1.2.1.8ColumncpqRackCommonEnclosureTempConditionread-onlymandatoryThe Temperature sensor condition. This value will be one of the following: other(1) Temperature could not be determined. ok(2) The temperature sensor is within…
1.3.6.1.4.1.232.22.2.3.1.2.1.9ColumncpqRackCommonEnclosureTempTyperead-onlymandatoryThis specifies the type of this instance of temperature sensor. This value will be one of the following: other(1) Temperature threshold type could not be deter…
1.3.6.1.4.1.232.22.2.3.1.2.1.10ColumncpqRackCommonEnclosureTempSensorEnclosureSerialNumread-onlymandatoryThe serial number of the enclosure containing this temperature sensor. The string will be empty if the enclosure does not report the serial number or it could …
1.3.6.1.4.1.232.22.2.3.1.3TablecpqRackCommonEnclosureFanTablenot-accessiblemandatoryA table of rack enclosure fan information.
1.3.6.1.4.1.232.22.2.3.1.3.1RowcpqRackCommonEnclosureFanEntrynot-accessiblemandatoryA rack enclosure fan description.
1.3.6.1.4.1.232.22.2.3.1.3.1.1ColumncpqRackCommonEnclosureFanRackread-onlymandatoryA number that uniquely specifies this rack.
1.3.6.1.4.1.232.22.2.3.1.3.1.2ColumncpqRackCommonEnclosureFanChassisread-onlymandatoryA number that uniquely specifies this enclosure in the rack.
1.3.6.1.4.1.232.22.2.3.1.3.1.3ColumncpqRackCommonEnclosureFanIndexread-onlymandatoryA number that uniquely specifies this fan within this enclosure in the rack.
1.3.6.1.4.1.232.22.2.3.1.3.1.4ColumncpqRackCommonEnclosureFanEnclosureNameread-onlymandatoryThe name of the enclosure. The string will be empty if the enclosure does not report the name or it could not be determined.
1.3.6.1.4.1.232.22.2.3.1.3.1.5ColumncpqRackCommonEnclosureFanLocationread-onlymandatoryThe location description of the fan within the enclosure. The string will be empty if the location could not be determined.
1.3.6.1.4.1.232.22.2.3.1.3.1.6ColumncpqRackCommonEnclosureFanPartNumberread-onlymandatoryThe part number of the enclosure fan. The string will be empty if the part number could not be determined.
1.3.6.1.4.1.232.22.2.3.1.3.1.7ColumncpqRackCommonEnclosureFanSparePartNumberread-onlymandatoryThe spare part number of the enclosure fan. The string will be empty if the part number could not be determined.
1.3.6.1.4.1.232.22.2.3.1.3.1.8ColumncpqRackCommonEnclosureFanPresentread-onlymandatoryThis specifies if the fan described is present in the system.
1.3.6.1.4.1.232.22.2.3.1.3.1.9ColumncpqRackCommonEnclosureFanRedundantread-onlymandatoryThis specifies if the fan is in a redundant configuration.
1.3.6.1.4.1.232.22.2.3.1.3.1.10ColumncpqRackCommonEnclosureFanRedundantGroupIdread-onlymandatoryThis specifies the group number for redundant fans within this enclosure.
1.3.6.1.4.1.232.22.2.3.1.3.1.11ColumncpqRackCommonEnclosureFanConditionread-onlymandatoryThe condition of the fan. This value will be one of the following: other(1) Fan status detection is not supported. ok(2) The fan is operating properly. degrade…
1.3.6.1.4.1.232.22.2.3.1.3.1.12ColumncpqRackCommonEnclosureFanEnclosureSerialNumread-onlymandatoryThe serial number of the enclosure containing the fan. The string will be empty if the enclosure does not report the serial number or it could not be determine…
1.3.6.1.4.1.232.22.2.3.1.4TablecpqRackCommonEnclosureFuseTablenot-accessiblemandatoryA table of rack enclosure fuse information.
1.3.6.1.4.1.232.22.2.3.1.4.1RowcpqRackCommonEnclosureFuseEntrynot-accessiblemandatoryA rack enclosure fuse description.
1.3.6.1.4.1.232.22.2.3.1.4.1.1ColumncpqRackCommonEnclosureFuseRackread-onlymandatoryA number that uniquely specifies this rack.
1.3.6.1.4.1.232.22.2.3.1.4.1.2ColumncpqRackCommonEnclosureFuseChassisread-onlymandatoryA number that uniquely specifies this enclosure in the rack.
1.3.6.1.4.1.232.22.2.3.1.4.1.3ColumncpqRackCommonEnclosureFuseIndexread-onlymandatoryA number that uniquely specifies the fuse within this enclosure.
1.3.6.1.4.1.232.22.2.3.1.4.1.4ColumncpqRackCommonEnclosureFuseEnclosureNameread-onlymandatoryThe name of the enclosure. The string will be empty if the enclosure does not report the name or it could not be determined.
1.3.6.1.4.1.232.22.2.3.1.4.1.5ColumncpqRackCommonEnclosureFuseLocationread-onlymandatoryThe location description of the fuse within the enclosure. The string will be empty if the location could not be determined.
1.3.6.1.4.1.232.22.2.3.1.4.1.6ColumncpqRackCommonEnclosureFusePresentread-onlymandatoryThis specifies if the fuse described is present in the system.
1.3.6.1.4.1.232.22.2.3.1.4.1.7ColumncpqRackCommonEnclosureFuseConditionread-onlymandatoryThe condition of the fuse. This value will be one of the following: other(1) Fuse status detection is not supported. ok(2) The fuse is operating properly. fail…
1.3.6.1.4.1.232.22.2.3.1.5TablecpqRackCommonEnclosureFruTablenot-accessiblemandatoryA table of rack enclosure field replaceable units information.
1.3.6.1.4.1.232.22.2.3.1.5.1RowcpqRackCommonEnclosureFruEntrynot-accessiblemandatoryA rack enclosure field replaceable unit description.
1.3.6.1.4.1.232.22.2.3.1.5.1.1ColumncpqRackCommonEnclosureFruRackread-onlymandatoryA number that uniquely specifies this rack.
1.3.6.1.4.1.232.22.2.3.1.5.1.2ColumncpqRackCommonEnclosureFruChassisread-onlymandatoryA number that uniquely specifies this enclosure in the rack.
1.3.6.1.4.1.232.22.2.3.1.5.1.3ColumncpqRackCommonEnclosureFruIndexread-onlymandatoryA number that uniquely specifies the FRU within this enclosure.
1.3.6.1.4.1.232.22.2.3.1.5.1.4ColumncpqRackCommonEnclosureFruEnclosureNameread-onlymandatoryThe name of the enclosure. The string will be empty if the enclosure does not report the name or it could not be determined.
1.3.6.1.4.1.232.22.2.3.1.5.1.5ColumncpqRackCommonEnclosureFruDescriptionread-onlymandatoryA description of the FRU component. The string will be empty if the enclosure does not report the description information.
1.3.6.1.4.1.232.22.2.3.1.5.1.6ColumncpqRackCommonEnclosureFruLocationread-onlymandatoryThe location description of the FRU within the enclosure. The string will be empty if the location could not be determined.
1.3.6.1.4.1.232.22.2.3.1.5.1.7ColumncpqRackCommonEnclosureFruAssemblyPartNumberread-onlymandatoryThe assembly part number of the FRU within the enclosure. The string will be empty if the enclosure does not report this information.
1.3.6.1.4.1.232.22.2.3.1.5.1.8ColumncpqRackCommonEnclosureFruSparePartNumberread-onlymandatoryThe spare part number of the FRU within the enclosure. The string will be empty if the enclosure does not report this information.
1.3.6.1.4.1.232.22.2.3.1.5.1.9ColumncpqRackCommonEnclosureFruAutoRevread-onlymandatoryThe auto revision number of the FRU within the enclosure. The string will be empty if the enclosure does not report this information.
1.3.6.1.4.1.232.22.2.3.1.5.1.10ColumncpqRackCommonEnclosureFruSerialNumread-onlymandatoryThe serial number of the FRU within the enclosure. The string will be empty if the enclosure does not report the serial number.
1.3.6.1.4.1.232.22.2.3.1.6TablecpqRackCommonEnclosureManagerTablenot-accessiblemandatoryA table of rack enclosure manager information.
1.3.6.1.4.1.232.22.2.3.1.6.1RowcpqRackCommonEnclosureManagerEntrynot-accessiblemandatoryA rack enclosure manager description.
1.3.6.1.4.1.232.22.2.3.1.6.1.1ColumncpqRackCommonEnclosureManagerRackread-onlymandatoryA number that uniquely specifies this rack.
1.3.6.1.4.1.232.22.2.3.1.6.1.2ColumncpqRackCommonEnclosureManagerChassisread-onlymandatoryA number that uniquely specifies this enclosure in the rack.
1.3.6.1.4.1.232.22.2.3.1.6.1.3ColumncpqRackCommonEnclosureManagerIndexread-onlymandatoryA number that uniquely specifies this manager within this enclosure in the rack.
1.3.6.1.4.1.232.22.2.3.1.6.1.4ColumncpqRackCommonEnclosureManagerEnclosureNameread-onlymandatoryThe name of the enclosure. The string will be empty if the enclosure does not report the name or it could not be determined.
1.3.6.1.4.1.232.22.2.3.1.6.1.5ColumncpqRackCommonEnclosureManagerLocationread-onlymandatoryThe location description of the manager within the enclosure. The string will be empty if the location could not be determined.
1.3.6.1.4.1.232.22.2.3.1.6.1.6ColumncpqRackCommonEnclosureManagerPartNumberread-onlymandatoryThe part number of the enclosure manager. The string will be empty if the part number could not be determined.
1.3.6.1.4.1.232.22.2.3.1.6.1.7ColumncpqRackCommonEnclosureManagerSparePartNumberread-onlymandatoryThe spare part number of the enclosure manager. The string will be empty if the part number could not be determined.
1.3.6.1.4.1.232.22.2.3.1.6.1.8ColumncpqRackCommonEnclosureManagerSerialNumread-onlymandatoryThe serial number of the enclosure manager. The string will be empty if the enclosure does not report the serial number or it could not be determined.
1.3.6.1.4.1.232.22.2.3.1.6.1.9ColumncpqRackCommonEnclosureManagerRoleread-onlymandatoryThis specifies the current role of the manager.
1.3.6.1.4.1.232.22.2.3.1.6.1.10ColumncpqRackCommonEnclosureManagerPresentread-onlymandatoryThis specifies if the manager described is present in the system.
1.3.6.1.4.1.232.22.2.3.1.6.1.11ColumncpqRackCommonEnclosureManagerRedundantread-onlymandatoryThis specifies if the manager is in a redundant configuration.
1.3.6.1.4.1.232.22.2.3.1.6.1.12ColumncpqRackCommonEnclosureManagerConditionread-onlymandatoryThe condition of the manager. This value will be one of the following: other(1) Manager status detection is not supported. ok(2) The manager is operating prope…
1.3.6.1.4.1.232.22.2.3.1.6.1.13ColumncpqRackCommonEnclosureManagerEnclosureSerialNumread-onlymandatoryThe serial number of the enclosure containing the manager. The string will be empty if the enclosure does not report the serial number or it could not be deter…
1.3.6.1.4.1.232.22.2.3.1.6.1.14ColumncpqRackCommonEnclosureManagerUUIDread-onlymandatoryThe universal unique identifier string of the manager. The string will be empty if the enclosure does not report the UUID string.
1.3.6.1.4.1.232.22.2.3.1.6.1.15ColumncpqRackCommonEnclosureManagerFWRevread-onlymandatoryThe firmware revision of the enclosure manager. The string will be empty if the enclosure does not report the firmware revision or does not contain firmware.
1.3.6.1.4.1.232.22.2.3.2NodecpqRackServerEnclosure
1.3.6.1.4.1.232.22.2.3.2.1TablecpqRackServerEnclosureTablenot-accessiblemandatoryA table of rack enclosure information for servers.
1.3.6.1.4.1.232.22.2.3.2.1.1RowcpqRackServerEnclosureEntrynot-accessiblemandatoryA server enclosure description.
1.3.6.1.4.1.232.22.2.3.2.1.1.1ColumncpqRackServerEnclosureRackread-onlymandatoryA number that uniquely specifies this rack.
1.3.6.1.4.1.232.22.2.3.2.1.1.2ColumncpqRackServerEnclosureIndexread-onlymandatoryA number that uniquely specifies this server enclosure in the rack.
1.3.6.1.4.1.232.22.2.3.2.1.1.3ColumncpqRackServerEnclosureNameread-onlymandatoryThe name of the server enclosure. The string will be empty if the enclosure does not report the name or it could not be determined.
1.3.6.1.4.1.232.22.2.3.2.1.1.4ColumncpqRackServerEnclosureMaxNumBladesread-onlymandatoryThe maximum number of server blades the enclosure can contain. The string will be empty if the enclosure does not report the name or it could not be determined.
1.3.6.1.4.1.232.22.2.3.2.1.1.5ColumncpqRackServerEnclosureMaxNumBladesXread-onlymandatoryThe maximum number of server blades in x-direction (from left to right) the enclosure can contain.
1.3.6.1.4.1.232.22.2.3.2.1.1.6ColumncpqRackServerEnclosureMaxNumBladesYread-onlymandatoryThe maximum number of server blades in y-direction (from top to bottom) the enclosure can contain.
1.3.6.1.4.1.232.22.2.3.2.1.1.7ColumncpqRackServerEnclosureSolutionsIdread-writeoptionalThe identifier is used to label enclosure as a BladeSystem Matrix enclosure. Octet Values ===== ============================== 1 Solutions platform identifier …
1.3.6.1.4.1.232.22.2.3.2.2ScalarcpqRackLastEAEEventread-onlyoptionalData for the last EAE event.
1.3.6.1.4.1.232.22.2.3.3NodecpqRackPowerEnclosure
1.3.6.1.4.1.232.22.2.3.3.1TablecpqRackPowerEnclosureTablenot-accessiblemandatoryA table of rack power enclosure information.
1.3.6.1.4.1.232.22.2.3.3.1.1RowcpqRackPowerEnclosureEntrynot-accessiblemandatoryA rack power enclosure description.
1.3.6.1.4.1.232.22.2.3.3.1.1.1ColumncpqRackPowerEnclosureRackread-onlymandatoryA number that uniquely specifies this rack.
1.3.6.1.4.1.232.22.2.3.3.1.1.2ColumncpqRackPowerEnclosureIndexread-onlymandatoryA number that uniquely specifies this power enclosure in the rack.
1.3.6.1.4.1.232.22.2.3.3.1.1.3ColumncpqRackPowerEnclosureNameread-onlymandatoryThe name of the power enclosure. The string will be empty if the enclosure does not report the name or it could not be determined.
1.3.6.1.4.1.232.22.2.3.3.1.1.4ColumncpqRackPowerEnclosureMgmtBoardSerialNumread-onlymandatoryThe serial number of the enclosure. The string will be empty if the enclosure does not report the serial number.
1.3.6.1.4.1.232.22.2.3.3.1.1.5ColumncpqRackPowerEnclosureRedundantread-onlymandatoryThis indicates if the power supply enclosure is in a redundant state.
1.3.6.1.4.1.232.22.2.3.3.1.1.6ColumncpqRackPowerEnclosureLoadBalancedread-onlymandatoryThis indicates if the power supply enclosure is in a load balanced state.
1.3.6.1.4.1.232.22.2.3.3.1.1.7ColumncpqRackPowerEnclosureInputPwrTyperead-onlymandatoryThis indicates type of input facility power.
1.3.6.1.4.1.232.22.2.3.3.1.1.8ColumncpqRackPowerEnclosurePwrFeedMaxread-onlymandatoryThis is the maximum facility power in watts. The maximum facility power being fed to this power enclosure. The value will be -1 if the power enclosure does not…
1.3.6.1.4.1.232.22.2.3.3.1.1.9ColumncpqRackPowerEnclosureConditionread-onlymandatoryThis indicates current condition of the power enclosure. other(1) The power enclosure condition could not be determined. ok(2) The power enclosure is operating…
1.3.6.1.4.1.232.22.2.3.3.1.1.10ColumncpqRackPowerEnclosureBladeAutopoweronread-writeoptionalThis indicates current condition of the power enclosure. other(1) The blade auto power on feature could not be determined. disabled(2) The enclosure will not a…
1.3.6.1.4.1.232.22.2.4NodecpqRackServer
1.3.6.1.4.1.232.22.2.4.1NodecpqRackServerBlade
1.3.6.1.4.1.232.22.2.4.1.1TablecpqRackServerBladeTablenot-accessiblemandatoryA table of rack server blade information.
1.3.6.1.4.1.232.22.2.4.1.1.1RowcpqRackServerBladeEntrynot-accessiblemandatoryA rack server blade description.
1.3.6.1.4.1.232.22.2.4.1.1.1.1ColumncpqRackServerBladeRackread-onlymandatoryA number that uniquely specifies this rack.
1.3.6.1.4.1.232.22.2.4.1.1.1.2ColumncpqRackServerBladeChassisread-onlymandatoryA number that uniquely specifies this enclosure in the rack.
1.3.6.1.4.1.232.22.2.4.1.1.1.3ColumncpqRackServerBladeIndexread-onlymandatoryA number that uniquely specifies this server blade within the enclosure.
1.3.6.1.4.1.232.22.2.4.1.1.1.4ColumncpqRackServerBladeNameread-onlymandatoryThe name of the server blade. The string will be empty if it could not be determined.
1.3.6.1.4.1.232.22.2.4.1.1.1.5ColumncpqRackServerBladeEnclosureNameread-onlymandatoryThe name of the enclosure which contains the blade. The string will be empty if the enclosure does not report the name or it could not be determined.
1.3.6.1.4.1.232.22.2.4.1.1.1.6ColumncpqRackServerBladePartNumberread-onlymandatoryThe part number of the server blade. The string will be empty if the part number could not be determined.
1.3.6.1.4.1.232.22.2.4.1.1.1.7ColumncpqRackServerBladeSparePartNumberread-onlymandatoryThe spare part number of the server blade. The string will be empty if the part number could not be determined.
1.3.6.1.4.1.232.22.2.4.1.1.1.8ColumncpqRackServerBladePositionread-onlymandatoryThe position or slot number of the server blade within the server enclosure. This will be -1 if the server enclosure does not report the information or it coul…
1.3.6.1.4.1.232.22.2.4.1.1.1.9ColumncpqRackServerBladeHeightread-onlymandatoryThe height dimension of the rack space taken by the server blade expressed in millimeters. This will be -1 if the rack does not report the information or it co…
1.3.6.1.4.1.232.22.2.4.1.1.1.10ColumncpqRackServerBladeWidthread-onlymandatoryThe width dimension of the rack space taken by the server blade expressed in millimeters. This will be -1 if the rack does not report the information or it cou…
1.3.6.1.4.1.232.22.2.4.1.1.1.11ColumncpqRackServerBladeDepthread-onlymandatoryThe depth dimension of the rack space taken by the server blade expressed in millimeters. This will be -1 if the rack does not report the information or it cou…
1.3.6.1.4.1.232.22.2.4.1.1.1.12ColumncpqRackServerBladePresentread-onlymandatoryThis specifies if the server blade described is present in the enclosure.
1.3.6.1.4.1.232.22.2.4.1.1.1.13ColumncpqRackServerBladeHasFusesread-onlymandatoryThe server blade contains fuses. This will be true(2) is the server blade contains fuses. The cpqRackCommonEnclosureFuseTable will contain the fuse specific in…
1.3.6.1.4.1.232.22.2.4.1.1.1.14ColumncpqRackServerBladeEnclosureSerialNumread-onlymandatoryThe serial number of the enclosure which contains the blade. The string will be empty if the enclosure does not report the serial number or it could not be det…
1.3.6.1.4.1.232.22.2.4.1.1.1.15ColumncpqRackServerBladeSlotsUsedread-onlymandatoryThe number of slot positions occupied by this server blade. This is used to indicate a server blade which may obscure an adjacent blade slot. This will be -1 i…
1.3.6.1.4.1.232.22.2.4.1.1.1.16ColumncpqRackServerBladeSerialNumread-onlymandatoryThe serial number of the server blade. The string will be empty if the system does not report the serial number function.
1.3.6.1.4.1.232.22.2.4.1.1.1.17ColumncpqRackServerBladeProductIdread-onlymandatoryThe product id string of the server blade. The string will be empty if the system does not report the product id function.
1.3.6.1.4.1.232.22.2.4.1.1.1.18ColumncpqRackServerBladeUidread-onlymandatoryThe server blade unique identifier (UUID). The string will be empty if the blade does not report the UUID or if it could not be determined.
1.3.6.1.4.1.232.22.2.4.1.1.1.19ColumncpqRackServerBladeSlotsUsedXread-onlymandatoryThe number of slot positions in x-direction (from left to right) occupied by this server blade. This is used to indicate a server blade which may obscure an ad…
1.3.6.1.4.1.232.22.2.4.1.1.1.20ColumncpqRackServerBladeSlotsUsedYread-onlymandatoryThe number of slot positions in y-direction (from top to bottom) occupied by this server blade. This is used to indicate a server blade which may obscure an ad…
1.3.6.1.4.1.232.22.2.4.1.1.1.21ColumncpqRackServerBladeStatusread-onlyoptionalThe health status of the blade. This will be other(1) if the rack does not report the information or if it could not be determined.
1.3.6.1.4.1.232.22.2.4.1.1.1.22ColumncpqRackServerBladeFaultMajorread-onlyoptionalThe major fault code of the blade fault reported by the enclosure manager. This will be -1 if the rack does not report the information or if it could not be de…
1.3.6.1.4.1.232.22.2.4.1.1.1.23ColumncpqRackServerBladeFaultMinorread-onlyoptionalThe minor fault code of the blade fault reported by the enclosure manager. This will be -1 if the rack does not report the information or if it could not be de…
1.3.6.1.4.1.232.22.2.4.1.1.1.24ColumncpqRackServerBladeFaultDiagnosticStringread-onlyoptionalThe server blade fault diagnostic string. This will contain a probable cause and potential diagnostic action to be taken to remedy the fault condition. The str…
1.3.6.1.4.1.232.22.2.4.1.1.1.25ColumncpqRackServerBladePoweredread-writeoptionalThe power state of the blade. This will be other(1) if the rack does not report the information or if it could not be determined.
1.3.6.1.4.1.232.22.2.4.1.1.1.26ColumncpqRackServerBladeUIDStateread-writeoptionalThe Unit Identifier LED. This value will be one of the following: other(1) The state of the LED could not be determined. Setting the LED state is not allowed. …
1.3.6.1.4.1.232.22.2.4.1.1.1.27ColumncpqRackServerBladeSystemBIOSRevisionread-onlyoptionalThe server blade system bios revision. The string will be empty if the blade does not report the system bios revision or if it could not be determined.
1.3.6.1.4.1.232.22.2.4.1.1.1.28ColumncpqRackServerBladeSystemBIOSFlashingStatusread-onlyoptionalBlade server system BIOS flashing / flash mode status indication. This will be other(1) if the rack does not report the information or if it could not be deter…
1.3.6.1.4.1.232.22.2.4.1.1.1.29ColumncpqRackServerBladeHasManagementDeviceread-onlyoptionalThe blade server contains one or more management devices. This will be true(2) if the blade server contains managers and false (1) if not or if it can't be det…
1.3.6.1.4.1.232.22.2.4.1.1.1.30ColumncpqRackServerBladeManagementDeviceFirmwareRevisionread-onlyoptionalThe server blade management device firwmware revision. The string will be empty if the blade does not report the management device firwmware revision or if it …
1.3.6.1.4.1.232.22.2.4.1.1.1.31ColumncpqRackServerBladeManagementDeviceFirmwareFlashingStatusread-onlyoptionalBlade server management device firwmware flashing / flash mode status indication. This will be other(1) if the rack does not report this information or if it c…
1.3.6.1.4.1.232.22.2.4.1.1.1.32ColumncpqRackServerBladeDiagnosticAdaptorPresenceread-onlyoptionalThis specifies if a blade diagnostic adaptor is currently plugged into the system.
1.3.6.1.4.1.232.22.2.4.1.1.1.33ColumncpqRackServerBladeASREnabledread-onlyoptionalIndicates whether the target blade server has Automatic Service Recovery feature enabled. This will be true(2) if the blade server has this feature eanbled and…
1.3.6.1.4.1.232.22.2.4.1.1.1.34ColumncpqRackServerBladeFrontIOBlankingModeStatusread-onlyoptionalIndicates whether the target blade server has the front IO ports blanking feature enabled. This will be Active(3) if the blade server has this feature eanbled,…
1.3.6.1.4.1.232.22.2.4.1.1.1.35ColumncpqRackServerBladePOSTStatusread-onlyoptionalBlade server power-on self test (POST) status. This value will be one of the following: other(1) The state of the blade POST could not be determined. started(2…
1.3.6.1.4.1.232.22.2.4.1.1.1.36ColumncpqRackServerBladePXEBootModeStatusread-onlyoptionalIndicates whether the target blade server is in PXE boot mode. This will be Active(3) if the blade server has this feature enbled, Inactive (2) if not, or Unkn…
1.3.6.1.4.1.232.22.2.4.1.1.1.37ColumncpqRackServerBladePendingBootOrderChangeread-writeoptionalBlade server pending boot order setting change state. This value will be one of the following: other(1) - Unknown or cannot be determined none(2) - No Changes …
1.3.6.1.4.1.232.22.2.4.1.1.1.38ColumncpqRackServerBladeWattageMaxread-onlyoptionalMaximum wattage the server has consumed during this power cycle.
1.3.6.1.4.1.232.22.2.4.1.1.1.39ColumncpqRackServerBladeWattageAvgread-onlyoptionalAverage wattage the server is consuming, averaged over a period defined by the product.
1.3.6.1.4.1.232.22.2.4.1.1.1.40ColumncpqRackServerBladeWattageMinread-onlyoptionalMinimum wattage the server has consumed, computed from a period defined by the product. Value will be 0 if not supported, but other wattage values are supporte…
1.3.6.1.4.1.232.22.2.4.2NodecpqRackServerNetworking
1.3.6.1.4.1.232.22.2.4.2.1TablecpqRackServerNetworkingTablenot-accessibleoptionalA table of rack server networking information.
1.3.6.1.4.1.232.22.2.4.2.1.1RowcpqRackServerNetworkingEntrynot-accessibleoptionalA rack server networking description.
1.3.6.1.4.1.232.22.2.4.2.1.1.1ColumncpqRackServerNetworkingRackread-onlyoptionalA number that uniquely specifies this rack.
1.3.6.1.4.1.232.22.2.4.2.1.1.2ColumncpqRackServerNetworkingChassisread-onlymandatoryA number that uniquely specifies this enclosure in the rack.
1.3.6.1.4.1.232.22.2.4.2.1.1.3ColumncpqRackServerNetworkingIndexread-onlyoptionalA number that uniquely specifies this server within the enclosure.
1.3.6.1.4.1.232.22.2.4.2.1.1.4ColumncpqRackServerNetworkingNameread-onlyoptionalThe name of the server. The string will be empty if it could not be determined.
1.3.6.1.4.1.232.22.2.4.2.1.1.5ColumncpqRackServerNetworkingEnclosureNameread-onlyoptionalThe name of the enclosure which contains the server. The string will be empty if the enclosure does not report the name or if it could not be determined.
1.3.6.1.4.1.232.22.2.4.2.1.1.6ColumncpqRackServerNetworkingEthernetInterfacesread-onlyoptionalA number that specifies the amount of Ethernet network interfaces in the server.
1.3.6.1.4.1.232.22.2.4.2.1.1.7ColumncpqRackServerNetworkingEthernetMACAddressread-onlyoptionalThe MAC address for the Ethernet NIC populated in the server. The string will be empty if it could not be determined.
1.3.6.1.4.1.232.22.2.4.3NodecpqRackServerTempSensor
1.3.6.1.4.1.232.22.2.4.3.1TablecpqRackServerTempSensorTablenot-accessibleoptionalA table of rack server temperature sensor information.
1.3.6.1.4.1.232.22.2.4.3.1.1RowcpqRackServerTempSensorEntrynot-accessibleoptionalA rack server temperature sensor description.
1.3.6.1.4.1.232.22.2.4.3.1.1.1ColumncpqRackServerTempSensorRackread-onlyoptionalA number that uniquely specifies this rack.
1.3.6.1.4.1.232.22.2.4.3.1.1.2ColumncpqRackServerTempSensorChassisread-onlyoptionalA number that uniquely specifies this enclosure in the rack.
1.3.6.1.4.1.232.22.2.4.3.1.1.3ColumncpqRackServerTempSensorIndexread-onlyoptionalA number that uniquely specifies this server within the enclosure.
1.3.6.1.4.1.232.22.2.4.3.1.1.4ColumncpqRackServerTempSensorNameread-onlyoptionalThe name of the server. The string will be empty if it could not be determined.
1.3.6.1.4.1.232.22.2.4.3.1.1.5ColumncpqRackServerTempSensorEnclosureNameread-onlyoptionalThe name of the enclosure which contains the server. The string will be empty if the enclosure does not report the name or if it could not be determined.
1.3.6.1.4.1.232.22.2.4.3.1.1.6ColumncpqRackServerTempSensorCountread-onlyoptionalA number that specifies the amount of temperature sensors in the server.
1.3.6.1.4.1.232.22.2.4.3.1.1.7ColumncpqRackServerTempSensorLocationread-onlyoptionalThe location description of the temperature sensor within the blade server. The string will be empty if it could not be determined.
1.3.6.1.4.1.232.22.2.4.3.1.1.8ColumncpqRackServerTempSensorCurrentread-onlyoptionalThis is the current temperature sensor reading in degrees celsius. If this value cannot be determined by software, then a value of -1 will be returned.
1.3.6.1.4.1.232.22.2.4.3.1.1.9ColumncpqRackServerTempSensorThresholdread-onlyoptionalThis is the threshold temperature sensor setting in degrees celsius. This is the temperature in which the sensor will be considered to be in a tripped state th…
1.3.6.1.4.1.232.22.2.4.3.1.1.10ColumncpqRackServerTempSensorConditionread-onlyoptionalThe Temperature sensor condition. This value will be one of the following: other(1) Temperature could not be determined. ok(2) The temperature sensor is within…
1.3.6.1.4.1.232.22.2.4.3.1.1.11ColumncpqRackServerTempSensorTyperead-onlyoptionalThis specifies the type of this instance of temperature sensor. This value will be one of the following: other(1) Temperature threshold type could not be deter…
1.3.6.1.4.1.232.22.2.5NodecpqRackPower
1.3.6.1.4.1.232.22.2.5.1NodecpqRackPowerSupply
1.3.6.1.4.1.232.22.2.5.1.1TablecpqRackPowerSupplyTablenot-accessiblemandatoryA table of rack power supply information.
1.3.6.1.4.1.232.22.2.5.1.1.1RowcpqRackPowerSupplyEntrynot-accessiblemandatoryA rack power supply description.
1.3.6.1.4.1.232.22.2.5.1.1.1.1ColumncpqRackPowerSupplyRackread-onlymandatoryA number that uniquely specifies this rack.
1.3.6.1.4.1.232.22.2.5.1.1.1.2ColumncpqRackPowerSupplyChassisread-onlymandatoryA number that uniquely specifies this power enclosure in the rack.
1.3.6.1.4.1.232.22.2.5.1.1.1.3ColumncpqRackPowerSupplyIndexread-onlymandatoryA number that uniquely specifies this power supply in the enclosure.
1.3.6.1.4.1.232.22.2.5.1.1.1.4ColumncpqRackPowerSupplyEnclosureNameread-onlymandatoryThe name of the power supply enclosure in which this power supply resides. The string will be empty if the enclosure does not report the name or it could not b…
1.3.6.1.4.1.232.22.2.5.1.1.1.5ColumncpqRackPowerSupplySerialNumread-onlymandatoryThe serial number of the power supply. The string will be empty if the power supply does not report the serial number.
1.3.6.1.4.1.232.22.2.5.1.1.1.6ColumncpqRackPowerSupplyPartNumberread-onlymandatoryThe part number of the power supply. The string will be empty if the power supply does not report this function.
1.3.6.1.4.1.232.22.2.5.1.1.1.7ColumncpqRackPowerSupplySparePartNumberread-onlymandatoryThe spare part number of the power supply. The string will be empty if the power supply does not report this function.
1.3.6.1.4.1.232.22.2.5.1.1.1.8ColumncpqRackPowerSupplyFWRevread-onlymandatoryThe firmware revision of the power supply. The string will be empty if the power supply does not report the firmware revision.
1.3.6.1.4.1.232.22.2.5.1.1.1.9ColumncpqRackPowerSupplyMaxPwrOutputread-onlymandatoryThe maximum power output of the power supply in watts. The value will be -1 if the power supply does not report the value.
1.3.6.1.4.1.232.22.2.5.1.1.1.10ColumncpqRackPowerSupplyCurPwrOutputread-onlymandatoryThe current power output of the power supply in watts. The value will be -1 if the power supply does not report the value.
1.3.6.1.4.1.232.22.2.5.1.1.1.11ColumncpqRackPowerSupplyPositionread-onlymandatoryThe position of the power supply within the power enclosure. This will be -1 if the power enclosure does not report the power supply information or it could no…
1.3.6.1.4.1.232.22.2.5.1.1.1.12ColumncpqRackPowerSupplyIntakeTempread-onlymandatoryThe current air temperature at the intake of the power supply in degrees celsius. The value will be -1 if the power supply does not report the value.
1.3.6.1.4.1.232.22.2.5.1.1.1.13ColumncpqRackPowerSupplyExhaustTempread-onlymandatoryThe current air temperature at the exhaust of the power supply in degrees celsius. The value will be -1 if the power supply does not report the value.
1.3.6.1.4.1.232.22.2.5.1.1.1.14ColumncpqRackPowerSupplyStatusread-onlymandatoryThe status of the power supply.
1.3.6.1.4.1.232.22.2.5.1.1.1.15ColumncpqRackPowerSupplyInputLineStatusread-onlymandatoryThe status of line input power.
1.3.6.1.4.1.232.22.2.5.1.1.1.16ColumncpqRackPowerSupplyPresentread-onlymandatoryThis specifies if the power supply described is present in the enclosure.
1.3.6.1.4.1.232.22.2.5.1.1.1.17ColumncpqRackPowerSupplyConditionread-onlymandatoryThe condition of the power supply. This value will be one of the following: other(1) The status could not be determined or not present. ok(2) The power supply …
1.3.6.1.4.1.232.22.2.5.1.1.1.18ColumncpqRackPowerSupplyEnclosureSerialNumread-onlymandatoryThe serial number of the power supply enclosure in which this power supply resides. The string will be empty if the enclosure does not report the serial number…
1.3.6.1.4.1.232.22.2.5.1.1.1.19ColumncpqRackPowerSupplyMeterPortread-onlymandatoryThe corresponding meter used to measure current for this power supply The integer will be -1 if the enclosure does not report the value or it could not be dete…
1.3.6.1.4.1.232.22.2.5.1.1.1.20ColumncpqRackPowerSupplyInputCurrentread-onlymandatoryInput current for the power supply The integer will be -1 if the enclosure does not report the value or it could not be determined.
1.3.6.1.4.1.232.22.2.5.1.1.1.21ColumncpqRackPowerSupplyInputPowerread-onlymandatoryInput wattage for the power supply The integer will be -1 if the enclosure does not report the value or it could not be determined.
1.3.6.1.4.1.232.22.2.5.1.1.1.22ColumncpqRackPowerSupplyInputVoltageread-onlymandatoryInput voltage for the power supply The integer will be -1 if the enclosure does not report the value or it could not be determined.
1.3.6.1.4.1.232.22.2.5.1.1.1.23ColumncpqRackPowerSupplyOutputCurrentread-onlymandatoryOutput current for the power supply The integer will be -1 if the enclosure does not report the value or it could not be determined.
1.3.6.1.4.1.232.22.2.5.1.1.1.24ColumncpqRackPowerSupplyOutputPowerread-onlymandatoryOutput wattage for the power supply The integer will be -1 if the enclosure does not report the value or it could not be determined.
1.3.6.1.4.1.232.22.2.5.1.1.1.25ColumncpqRackPowerSupplyOutputVoltageread-onlymandatoryOutput voltage for the power supply The integer will be -1 if the enclosure does not report the value or it could not be determined.
1.3.6.1.4.1.232.22.2.5.2NodecpqRackPowerMeter
1.3.6.1.4.1.232.22.2.5.2.1TablecpqRackPowerMeterTablenot-accessiblemandatoryA table of rack power meter information.
1.3.6.1.4.1.232.22.2.5.2.1.1RowcpqRackPowerMeterEntrynot-accessiblemandatoryA rack power meter description.
1.3.6.1.4.1.232.22.2.5.2.1.1.1ColumncpqRackPowerMeterRackread-onlymandatoryA number that uniquely specifies this rack.
1.3.6.1.4.1.232.22.2.5.2.1.1.2ColumncpqRackPowerMeterChassisread-onlymandatoryA number that uniquely specifies this power enclosure in the rack.
1.3.6.1.4.1.232.22.2.5.2.1.1.3ColumncpqRackPowerMeterIndexread-onlymandatoryA number that uniquely specifies this power meter in the enclosure.
1.3.6.1.4.1.232.22.2.5.2.1.1.4ColumncpqRackPowerMeterTyperead-onlymandatoryClass type of power meter - for example 480V The string will be empty if the enclosure does not report the name or it could not be determined.
1.3.6.1.4.1.232.22.2.5.2.1.1.5ColumncpqRackPowerMeterPortread-onlymandatoryWhich port on the power enclosure interfaces to this meter The value will be -1 if the power supply does not report this.
1.3.6.1.4.1.232.22.2.5.2.1.1.6ColumncpqRackPowerMeterStatusread-onlymandatoryOperational status value bit field (in hex) from the power meter. Used for diagnostic purposes. Bit definitions are as follows: bit 3 is for SPI communications…
1.3.6.1.4.1.232.22.2.5.2.1.1.7ColumncpqRackPowerMeterCurrentread-onlymandatoryThe current measured by the power meter The value will be -1 if the power supply does not report this.
1.3.6.1.4.1.232.22.2.5.2.1.1.8ColumncpqRackPowerMeterWattageread-onlymandatoryThe total wattage measured by the power meter The value will be -1 if the power supply does not report this.
1.3.6.1.4.1.232.22.2.6NodecpqRackNetwork
1.3.6.1.4.1.232.22.2.6.1NodecpqRackNetConnector
1.3.6.1.4.1.232.22.2.6.1.1TablecpqRackNetConnectorTablenot-accessiblemandatoryA table of rack network connector information.
1.3.6.1.4.1.232.22.2.6.1.1.1RowcpqRackNetConnectorEntrynot-accessiblemandatoryA rack network connector description.
1.3.6.1.4.1.232.22.2.6.1.1.1.1ColumncpqRackNetConnectorRackread-onlymandatoryA number that uniquely specifies this rack.
1.3.6.1.4.1.232.22.2.6.1.1.1.2ColumncpqRackNetConnectorChassisread-onlymandatoryA number that uniquely specifies this server enclosure in the rack.
1.3.6.1.4.1.232.22.2.6.1.1.1.3ColumncpqRackNetConnectorIndexread-onlymandatoryA number that uniquely specifies this network connector in the rack.
1.3.6.1.4.1.232.22.2.6.1.1.1.4ColumncpqRackNetConnectorEnclosureNameread-onlymandatoryThe name of the network connector enclosure. The string will be empty if the enclosure does not report the name or it could not be determined.
1.3.6.1.4.1.232.22.2.6.1.1.1.5ColumncpqRackNetConnectorNameread-onlymandatoryThe name of the network connector. The string will be empty if the network connector does not report the name or it could not be determined.
1.3.6.1.4.1.232.22.2.6.1.1.1.6ColumncpqRackNetConnectorModelread-onlymandatoryThe model name of the network connector. The string will be empty if the network connector does not report the model information.
1.3.6.1.4.1.232.22.2.6.1.1.1.7ColumncpqRackNetConnectorSerialNumread-onlymandatoryThe serial number of the network connector. The string will be empty if the network connector does not report the serial number.
1.3.6.1.4.1.232.22.2.6.1.1.1.8ColumncpqRackNetConnectorPartNumberread-onlymandatoryThe part number of the network connector. The string will be empty if the enclosure does not report this function.
1.3.6.1.4.1.232.22.2.6.1.1.1.9ColumncpqRackNetConnectorSparePartNumberread-onlymandatoryThe spare part number of the network connector. The string will be empty if the enclosure does not report this function.
1.3.6.1.4.1.232.22.2.6.1.1.1.10ColumncpqRackNetConnectorFWRevread-onlymandatoryThe firmware revision of the network connector. The string will be empty if the network connector does not report the firmware revision.
1.3.6.1.4.1.232.22.2.6.1.1.1.11ColumncpqRackNetConnectorTyperead-onlymandatoryThe type of network connector within the enclosure.
1.3.6.1.4.1.232.22.2.6.1.1.1.12ColumncpqRackNetConnectorLocationread-onlymandatoryThe location of the network connector within the enclosure.
1.3.6.1.4.1.232.22.2.6.1.1.1.13ColumncpqRackNetConnectorPresentread-onlymandatoryThis specifies if the network connector described is present in the enclosure.
1.3.6.1.4.1.232.22.2.6.1.1.1.14ColumncpqRackNetConnectorHasFusesread-onlymandatoryThe network connector contains fuses. This will be true(2) is the network connector contains fuses. The cpqRackCommonEnclosureFuseTable will contain the fuse s…
1.3.6.1.4.1.232.22.2.6.1.1.1.15ColumncpqRackNetConnectorEnclosureSerialNumread-onlymandatoryThe serial number of the enclosure containing the network connector. The string will be empty if the enclosure does not report the serial number or it could no…
1.3.6.1.4.1.232.22.2.6.1.1.1.16ColumncpqRackNetConnectorTechnologyTyperead-onlymandatoryThe type of network connector within the enclosure.
1.3.6.1.4.1.232.22.2.6.1.1.1.17ColumncpqRackNetConnectorDeviceTyperead-onlymandatoryThe type of interrconnect in the enclosure. This will be -1 if it is not reported or can not be deteremined.
1.3.6.1.4.1.232.22.2.6.2TablecpqRackNetworkAddressesTablenot-accessiblemandatoryA table of rack network addresses.
1.3.6.1.4.1.232.22.2.6.2.1RowcpqRackNetworkAddressesEntrynot-accessiblemandatoryArray of ALL the network addresses of the system generating the indication. This may include IPv4 addresses (based on IETF RFC 1208) or IPv6 addresses (based o…
1.3.6.1.4.1.232.22.2.6.2.1.1ColumncpqRackNetworkAddressesread-onlymandatoryA network address of the system generating the indication.
1.3.6.1.4.1.232.22.2.7NodecpqRackHW
1.3.6.1.4.1.232.22.2.7.1ScalarcpqRackHWPartNumberread-onlyoptionalPart number for the hardware generating the indication.
1.3.6.1.4.1.232.22.2.7.2TablecpqRackHWFirmwareVersionTablenot-accessibleoptionalA table of rack firmware versions.
1.3.6.1.4.1.232.22.2.7.2.1RowcpqRackHWFirmwareVersionEntrynot-accessibleoptionalArray of versions of firmware for the hardware associated with the indication.
1.3.6.1.4.1.232.22.2.7.2.1.1ColumncpqRackHWFirmwareVersionread-onlyoptionalA version of firmware for the hardware associated with the indication.
1.3.6.1.4.1.232.22.2.7.3ScalarcpqRackHWManufacturerread-onlyoptionalManufacturer of the hardware associated with the indication.Device indication hardware manufacturer.
1.3.6.1.4.1.232.22.2.7.4TablecpqRackHWSerialNumberTablenot-accessibleoptionalA table of rack hardware serial numbers.
1.3.6.1.4.1.232.22.2.7.4.1RowcpqRackHWSerialNumberEntrynot-accessibleoptionalArray of all the serial numbers of the hardware associated with the indication.
1.3.6.1.4.1.232.22.2.7.4.1.1ColumncpqRackHWSerialNumberread-onlyoptionalA serial number of the hardware associated with the indication.
1.3.6.1.4.1.232.22.2.7.5ScalarcpqRackHWFRUDetailsread-onlyoptionalThis is used to provide miscellaneous FRU specific details Some examples are DIMM size, Processor stepping info etc.
1.3.6.1.4.1.232.22.2.7.6ScalarcpqRackHWDevicePermanentNameFormatread-onlyoptionalThe format of the DevicePermanentName property is interpreted based upon the value of this property. Values are defined as: 1 - unknown. The format is not mean…
1.3.6.1.4.1.232.22.2.7.7ScalarcpqRackHWOtherPermanentNameFormatread-onlyoptionalA string defining other values for DevicePermanentFormat. It is empty unless DevicePermanentFormat value is other.
1.3.6.1.4.1.232.22.2.8NodecpqRackErs
1.3.6.1.4.1.232.22.2.8.1ScalarcpqRackErsTransactionTyperead-onlymandatoryEmbedded Remote Support transaction type. The following values are defined: registration(1) Registration operation with Insight Remote Host or Insight Online H…
1.3.6.1.4.1.232.22.2.8.2ScalarcpqRackErsConnectionModelread-onlymandatoryEmbedded Remote Support connection model configured on the Onboard Administrator.
1.3.6.1.4.1.232.22.2.8.3ScalarcpqRackErsFailureCoderead-onlymandatoryEmbedded Remote Support transaction failure code.
1.3.6.1.4.1.232.22.2.8.4ScalarcpqRackErsRemoteHostread-onlymandatoryRemote destination server's hostname and port as configured on the Onboard Administrator. Example: myremotehost.hpe.com:6789
1.3.6.1.4.1.232.22.2.9NodecpqRackEnvironmental
1.3.6.1.4.1.232.22.2.9.1NodecpqRackThermalController
1.3.6.1.4.1.232.22.2.9.1.1TablecpqRackThermalControllerTablenot-accessiblemandatoryA table containing the envirnomental controllers in the rack
1.3.6.1.4.1.232.22.2.9.1.1.1RowcpqRackThermalControllerEntrynot-accessiblemandatoryEntry containing thermal sensor readings
1.3.6.1.4.1.232.22.2.9.1.1.1.1ColumncpqRackThermalControllerIndexread-onlymandatoryA number that uniquely specifies this thermal controller in the rack.
1.3.6.1.4.1.232.22.2.9.1.1.1.2ColumncpqRackThermalControllerLeakDetect1read-onlymandatoryTRUE if sensor 1 detected a leak
1.3.6.1.4.1.232.22.2.9.1.1.1.3ColumncpqRackThermalControllerLeakDetect2read-onlymandatoryTRUE if sensor 2 detected a leak
1.3.6.1.4.1.232.22.2.9.1.1.1.4ColumncpqRackThermalControllerLeakDetect3read-onlymandatoryTRUE if sensor 3 detected a leak
1.3.6.1.4.1.232.22.2.9.1.1.1.5ColumncpqRackThermalControllerLeakDetectFacilityread-onlymandatoryTRUE if overhead sensor detected a leak
1.3.6.1.4.1.232.22.2.9.1.1.1.6ColumncpqRackThermalControllerDoorSensorFrontread-onlymandatory1 if front door is open
1.3.6.1.4.1.232.22.2.9.1.1.1.7ColumncpqRackThermalControllerDoorSensorRearread-onlymandatory1 if rear door is open
1.3.6.1.4.1.232.22.2.9.1.1.1.8ColumncpqRackThermalControllerDoorControlFrontread-writemandatory1 to open front door
1.3.6.1.4.1.232.22.2.9.1.1.1.9ColumncpqRackThermalControllerDoorControlRear1read-writemandatory1 to open rear door
1.3.6.1.4.1.232.22.2.9.1.1.1.10ColumncpqRackThermalControllerDoorControlRear2read-writemandatory1 to open rear door
1.3.6.1.4.1.232.22.2.9.1.1.1.11ColumncpqRackThermalControllerAirTempSensorFront1read-onlymandatoryFront air temperature in C
1.3.6.1.4.1.232.22.2.9.1.1.1.12ColumncpqRackThermalControllerAirTempSensorFront2read-onlymandatoryFront air temperature in C
1.3.6.1.4.1.232.22.2.9.1.1.1.13ColumncpqRackThermalControllerAirTempSensorFront3read-onlymandatoryFront air temperature in C
1.3.6.1.4.1.232.22.2.9.1.1.1.14ColumncpqRackThermalControllerAirTempSensorFront4read-onlymandatoryFront air temperature in C
1.3.6.1.4.1.232.22.2.9.1.1.1.15ColumncpqRackThermalControllerAirTempSensorRear1read-onlymandatoryRear air temperature in C
1.3.6.1.4.1.232.22.2.9.1.1.1.16ColumncpqRackThermalControllerAirTempSensorRear2read-onlymandatoryRear air temperature in C
1.3.6.1.4.1.232.22.2.9.1.1.1.17ColumncpqRackThermalControllerAirTempSensorRear3read-onlymandatoryRear air temperature in C
1.3.6.1.4.1.232.22.2.9.1.1.1.18ColumncpqRackThermalControllerAirTempSensorRear4read-onlymandatoryRear air temperature in C
1.3.6.1.4.1.232.22.2.9.1.1.1.19ColumncpqRackThermalControllerControlValveSupplyread-onlymandatorySupply valve status
1.3.6.1.4.1.232.22.2.9.1.1.1.20ColumncpqRackThermalControllerControlValveReturnread-onlymandatoryReturn valve status
1.3.6.1.4.1.232.22.2.9.1.1.1.21ColumncpqRackThermalControllerWaterTempSupplyread-onlymandatoryWater temperature supply in C
1.3.6.1.4.1.232.22.2.9.1.1.1.22ColumncpqRackThermalControllerWaterTempReturnread-onlymandatoryWater temperature return in C
1.3.6.1.4.1.232.22.2.9.1.1.1.23ColumncpqRackThermalControllerITFlowSensorread-onlymandatoryFlow sensor to IT equipment
1.3.6.1.4.1.232.22.2.9.1.1.1.24ColumncpqRackThermalControllerCDUFlowSensorread-onlymandatoryFlow sensor to CDU
1.3.6.1.4.1.232.22.2.9.1.1.1.25ColumncpqRackThermalControllerWaterPressureSupplyread-onlymandatorySupply water pressure
1.3.6.1.4.1.232.22.2.9.1.1.1.26ColumncpqRackThermalControllerWaterPressureReturnread-onlymandatoryReturn water pressure
1.3.6.1.4.1.232.22.2.9.1.1.1.27ColumncpqRackThermalControllerARPOread-onlymandatoryEmergency power off status
1.3.6.1.4.1.232.22.2.9.1.1.1.28ColumncpqRackThermalControllerChassisRopeSensor1read-onlymandatoryLeak detected by rope sensor 1
1.3.6.1.4.1.232.22.2.9.1.1.1.29ColumncpqRackThermalControllerChassisRopeSensor2read-onlymandatoryLeak detected by rope sensor 2
1.3.6.1.4.1.232.22.2.9.1.1.1.30ColumncpqRackThermalControllerChassisRopeSensor3read-onlymandatoryLeak detected by rope sensor 3
1.3.6.1.4.1.232.22.2.9.1.1.1.31ColumncpqRackThermalControllerChassisRopeSensor4read-onlymandatoryLeak detected by rope sensor 4
1.3.6.1.4.1.232.22.2.9.1.1.1.32ColumncpqRackThermalControllerOnBoardTempread-onlymandatoryThermal controller board temperature in C
1.3.6.1.4.1.232.22.2.9.1.1.1.33ColumncpqRackThermalControllerOnBoardHumidityread-onlymandatoryEnvironmental relative humidity
1.3.6.1.4.1.232.22.2.9.1.1.1.34ColumncpqRackThermalControllerBatteryread-onlymandatoryPresence of thermal controller battery
1.3.6.1.4.1.232.22.2.9.1.1.1.35ColumncpqRackThermalControllerAPMCommunicationsread-onlymandatoryAPM Communications Status
1.3.6.1.4.1.232.22.2.9.1.1.1.36ColumncpqRackEnvironmentalTrapDescriptionread-onlymandatoryTrap Description including threshold information: Sensor = string, Lo threshold = integer, Hi threshold = integer
1.3.6.1.4.1.232.22.2.10NodecpqRackCdu
1.3.6.1.4.1.232.22.2.10.1NodecpqRackCduApolloController
1.3.6.1.4.1.232.22.2.10.1.1TablecpqRackCduApolloControllerTablenot-accessiblemandatoryA table of rack Cdu controller information.
1.3.6.1.4.1.232.22.2.10.1.1.1RowcpqRackCduApolloControllerEntrynot-accessiblemandatoryA rack Cdu controller description.
1.3.6.1.4.1.232.22.2.10.1.1.1.1ColumncpqRackCduApolloControllerCduIndexread-onlymandatoryA number that uniquely specifies this Cdu in the rack.
1.3.6.1.4.1.232.22.2.10.1.1.1.2ColumncpqRackCduApolloControllerFwVersionread-onlymandatoryThis Cdu controller FW version.
1.3.6.1.4.1.232.22.2.10.1.1.1.3ColumncpqRackCduApolloControllerPlanAddressread-onlymandatoryThis Cdu controller PLAN address.
1.3.6.1.4.1.232.22.2.10.1.1.1.4ColumncpqRackCduApolloControllerPlanStatusread-onlymandatoryThis Cdu controller PLAN status.
1.3.6.1.4.1.232.22.2.10.1.1.1.5ColumncpqRackCduApolloControllerBmsFacilityWaterValveControlread-onlymandatoryThis Cdu controller BMS facility water valve control.
1.3.6.1.4.1.232.22.2.10.1.1.1.6ColumncpqRackCduApolloControllerBmsPumpBypassValveControlread-onlymandatoryThis Cdu controller BMS pump bypass valve control.
1.3.6.1.4.1.232.22.2.10.1.1.1.7ColumncpqRackCduApolloControllerBmsPumpVfdControlread-onlymandatoryThis Cdu controller BMS pump VFD control.
1.3.6.1.4.1.232.22.2.10.1.1.1.8ColumncpqRackCduApolloControllerBmsHeartbeatread-onlymandatoryThis Cdu controller heartbeat.
1.3.6.1.4.1.232.22.2.10.2NodecpqRackCduApolloFacilityWater
1.3.6.1.4.1.232.22.2.10.2.1TablecpqRackCduApolloFacilityWaterTablenot-accessiblemandatoryA table of rack Cdu controller information.
1.3.6.1.4.1.232.22.2.10.2.1.1RowcpqRackCduApolloFacilityWaterEntrynot-accessiblemandatoryA rack Cdu controller description.
1.3.6.1.4.1.232.22.2.10.2.1.1.1ColumncpqRackCduApolloFacilityWaterCduIndexread-onlymandatoryA number that uniquely specifies this Cdu in the rack.
1.3.6.1.4.1.232.22.2.10.2.1.1.2ColumncpqRackCduApolloFacilityWaterSupplyTempread-onlymandatoryThis Cdu facility water inlet temperature.
1.3.6.1.4.1.232.22.2.10.2.1.1.3ColumncpqRackCduApolloFacilityWaterSupplyHiTempAlarmSpread-onlymandatoryThis Cdu high facility inlet temperature alarm set point.
1.3.6.1.4.1.232.22.2.10.2.1.1.4ColumncpqRackCduApolloFacilityWaterSupplyIsoValveStateread-onlymandatoryThis Cdu facility isolation valve 1 status (open/close). Facility supply.
1.3.6.1.4.1.232.22.2.10.2.1.1.5ColumncpqRackCduApolloFacilityWaterReturnTempread-onlymandatoryThis Cdu facility outlet temperature.
1.3.6.1.4.1.232.22.2.10.2.1.1.6ColumncpqRackCduApolloFacilityWaterReturnHiTempAlarmSpread-onlymandatoryThis Cdu facility outlet temperature alarm set point.
1.3.6.1.4.1.232.22.2.10.2.1.1.7ColumncpqRackCduApolloFacilityWaterReturnIsoValveStateread-onlymandatoryThis Cdu facility isolation valve 2 status (open/close). Facility return.
1.3.6.1.4.1.232.22.2.10.2.1.1.8ColumncpqRackCduApolloFacilityWaterRegulatingValveOpeningread-onlymandatoryThis Cdu water regulation valve output (from Carel controller).
1.3.6.1.4.1.232.22.2.10.2.1.1.9ColumncpqRackCduApolloFacilityWaterPressureHexDifferentialread-onlymandatoryThis Cdu facility heat exchanger differential pressure.
1.3.6.1.4.1.232.22.2.10.2.1.1.10ColumncpqRackCduApolloFacilityWaterLoDifferentialPressureAlarmSpread-onlymandatoryThis Cdu low facility heat exchanger differential pressure alarm set point.
1.3.6.1.4.1.232.22.2.10.2.1.1.11ColumncpqRackCduApolloFacilityWaterPressureInletread-onlymandatoryThis Cdu facility inlet pressure.
1.3.6.1.4.1.232.22.2.10.2.1.1.12ColumncpqRackCduApolloFacilityWaterPressureOutletread-onlymandatoryThis Cdu facility outlet pressure.
1.3.6.1.4.1.232.22.2.10.3NodecpqRackCduApolloItWater
1.3.6.1.4.1.232.22.2.10.3.1TablecpqRackCduApolloItWaterTablenot-accessiblemandatoryA table of rack Cdu controller information.
1.3.6.1.4.1.232.22.2.10.3.1.1RowcpqRackCduApolloItWaterEntrynot-accessiblemandatoryA rack Cdu controller description.
1.3.6.1.4.1.232.22.2.10.3.1.1.1ColumncpqRackCduApolloItWaterCduIndexread-onlymandatoryA number that uniquely specifies this Cdu in the rack.
1.3.6.1.4.1.232.22.2.10.3.1.1.2ColumncpqRackCduApolloItWaterSupplyTempread-onlymandatoryThis Cdu IT heat exchanger inlet/supply temperature.
1.3.6.1.4.1.232.22.2.10.3.1.1.3ColumncpqRackCduApolloItWaterSupplyHiDischargeTempSpread-onlymandatoryThis Cdu high IT discharge temperature set point.
1.3.6.1.4.1.232.22.2.10.3.1.1.4ColumncpqRackCduApolloItWaterSupplyIsoValveStateread-onlymandatoryThis Cdu IT isolation valve 1 state (open/close). IT supply.
1.3.6.1.4.1.232.22.2.10.3.1.1.5ColumncpqRackCduApolloItWaterReturnTempread-onlymandatoryThis Cdu IT heat exchanger discharge/return temperature.
1.3.6.1.4.1.232.22.2.10.3.1.1.6ColumncpqRackCduApolloItWaterReturnIsoValveStateread-onlymandatoryThis Cdu IT isolation valve 2 state (open/close). IT return.
1.3.6.1.4.1.232.22.2.10.3.1.1.7ColumncpqRackCduApolloItWaterPumpSpeedread-onlymandatoryThis Cdu IT pump VFD output (from Carel controller).
1.3.6.1.4.1.232.22.2.10.3.1.1.8ColumncpqRackCduApolloItWaterPumpPowerread-onlymandatoryThis Cdu IT pump power (calculated).
1.3.6.1.4.1.232.22.2.10.3.1.1.9ColumncpqRackCduApolloItWaterPumpSupplyTempSpread-onlymandatoryThis Cdu IT pump supply temperature set point.
1.3.6.1.4.1.232.22.2.10.3.1.1.10ColumncpqRackCduApolloItWaterVfdControlLocationread-onlymandatoryThis Cdu IT VFD control location
1.3.6.1.4.1.232.22.2.10.3.1.1.11ColumncpqRackCduApolloItWaterVfdCurrentread-onlymandatoryThis Cdu IT VFD current.
1.3.6.1.4.1.232.22.2.10.3.1.1.12ColumncpqRackCduApolloItWaterVfdDcVoltageread-onlymandatoryThis Cdu IT VFD DC voltage.
1.3.6.1.4.1.232.22.2.10.3.1.1.13ColumncpqRackCduApolloItWaterVfdTemperatureread-onlymandatoryThis Cdu IT VFD temperature.
1.3.6.1.4.1.232.22.2.10.3.1.1.14ColumncpqRackCduApolloItWaterVfdExternalControlSignalread-onlymandatoryThis Cdu IT VFD external control signal.
1.3.6.1.4.1.232.22.2.10.3.1.1.15ColumncpqRackCduApolloItWaterVfdFaultWord1read-onlymandatoryThis Cdu IT VFD fault word1.
1.3.6.1.4.1.232.22.2.10.3.1.1.16ColumncpqRackCduApolloItWaterVfdFaultWord2read-onlymandatoryThis Cdu IT VFD fault word2.
1.3.6.1.4.1.232.22.2.10.3.1.1.17ColumncpqRackCduApolloItWaterVfdFaultWord3read-onlymandatoryThis Cdu IT VFD fault word3.
1.3.6.1.4.1.232.22.2.10.3.1.1.18ColumncpqRackCduApolloItWaterVfdFrequencyread-onlymandatoryThis Cdu IT VFD frequency.
1.3.6.1.4.1.232.22.2.10.3.1.1.19ColumncpqRackCduApolloItWaterVfdKwhCounterread-onlymandatoryThis Cdu IT VFD KWh counter.
1.3.6.1.4.1.232.22.2.10.3.1.1.20ColumncpqRackCduApolloItWaterVfdMwhCounterread-onlymandatoryThis Cdu IT VFD MWh counter.
1.3.6.1.4.1.232.22.2.10.3.1.1.21ColumncpqRackCduApolloItWaterVfdOutputVoltageread-onlymandatoryThis Cdu IT VFD output voltage.
1.3.6.1.4.1.232.22.2.10.3.1.1.22ColumncpqRackCduApolloItWaterVfdPowerReadingread-onlymandatoryThis Cdu IT VFD power reading.
1.3.6.1.4.1.232.22.2.10.3.1.1.23ColumncpqRackCduApolloItWaterVfdRunTimeread-onlymandatoryThis Cdu IT VFD runtime.
1.3.6.1.4.1.232.22.2.10.3.1.1.24ColumncpqRackCduApolloItWaterVfdSpeedread-onlymandatoryThis Cdu IT VFD speed.
1.3.6.1.4.1.232.22.2.10.3.1.1.25ColumncpqRackCduApolloItWaterVfdTorqueread-onlymandatoryThis Cdu IT VFD torque.
1.3.6.1.4.1.232.22.2.10.3.1.1.26ColumncpqRackCduApolloItWaterMotorNominalCurrentread-onlymandatoryThis Cdu IT motor nominal current.
1.3.6.1.4.1.232.22.2.10.3.1.1.27ColumncpqRackCduApolloItWaterMotorNominalFrequencyread-onlymandatoryThis Cdu IT motor nominal frequency.
1.3.6.1.4.1.232.22.2.10.3.1.1.28ColumncpqRackCduApolloItWaterMotorNominalPowerread-onlymandatoryThis Cdu IT motor nominal power.
1.3.6.1.4.1.232.22.2.10.3.1.1.29ColumncpqRackCduApolloItWaterMotorNominalSpeedread-onlymandatoryThis Cdu IT motor nominal speed.
1.3.6.1.4.1.232.22.2.10.3.1.1.30ColumncpqRackCduApolloItWaterMotorNominalVoltageread-onlymandatoryThis Cdu IT motor nominal voltage.
1.3.6.1.4.1.232.22.2.10.3.1.1.31ColumncpqRackCduApolloItWaterMotorModbusStatusWordread-onlymandatoryThis Cdu IT motor modbus status word.
1.3.6.1.4.1.232.22.2.10.3.1.1.32ColumncpqRackCduApolloItWaterPressureHexDiffActualread-onlymandatoryThis Cdu IT heat exchanger differential pressure actual.
1.3.6.1.4.1.232.22.2.10.3.1.1.33ColumncpqRackCduApolloItWaterPressureDiffPressureSpread-onlymandatoryThis Cdu IT heat exchanger differential pressure setpoint.
1.3.6.1.4.1.232.22.2.10.3.1.1.34ColumncpqRackCduApolloItWaterPressureLoAlarmSpread-onlymandatoryThis Cdu IT pressure low alarm setpoint.
1.3.6.1.4.1.232.22.2.10.3.1.1.35ColumncpqRackCduApolloItWaterPressureHiAlarmSpread-onlymandatoryThis Cdu IT pressure high alarm setpoint.
1.3.6.1.4.1.232.22.2.10.3.1.1.36ColumncpqRackCduApolloItWaterPressureHexOutletread-onlymandatoryThis Cdu IT heat exchanger pressure outlet.
1.3.6.1.4.1.232.22.2.10.3.1.1.37ColumncpqRackCduApolloItWaterPressurePumpDischargeread-onlymandatoryThis Cdu IT pump discharge.
1.3.6.1.4.1.232.22.2.10.3.1.1.38ColumncpqRackCduApolloItWaterReservoirVacuumPumpOnread-onlymandatoryThis Cdu IT rerservoir vacuum pump on.
1.3.6.1.4.1.232.22.2.10.3.1.1.39ColumncpqRackCduApolloItWaterReservoirVacuumPressureCutInSpread-onlymandatoryThis Cdu IT reservoir vacuum pressure cut in setpoint.
1.3.6.1.4.1.232.22.2.10.3.1.1.40ColumncpqRackCduApolloItWaterReservoirVacuumPressureCutOutSpread-onlymandatoryThis Cdu IT reservoir vacuum pressure cut out setpoint.
1.3.6.1.4.1.232.22.2.10.3.1.1.41ColumncpqRackCduApolloItWaterReservoirVacuumLockOutOffsetread-onlymandatoryThis Cdu IT reservoir vacuum lock out offset.
1.3.6.1.4.1.232.22.2.10.3.1.1.42ColumncpqRackCduApolloItWaterReservoirVacuumLockedOutread-onlymandatoryThis Cdu IT reservoir vacuum locked out.
1.3.6.1.4.1.232.22.2.10.3.1.1.43ColumncpqRackCduApolloItWaterReservoirPressureread-onlymandatoryThis Cdu IT reservoir pressure.
1.3.6.1.4.1.232.22.2.10.3.1.1.44ColumncpqRackCduApolloItWaterReservoirVolumeread-onlymandatoryThis Cdu IT reservoir volume.
1.3.6.1.4.1.232.22.2.10.3.1.1.45ColumncpqRackCduApolloItWaterReservoirTankWaterLevelread-onlymandatoryThis Cdu IT reservoir tank water level.
1.3.6.1.4.1.232.22.2.10.3.1.1.46ColumncpqRackCduApolloItWaterReservoirWaterFillOnread-onlymandatoryThis Cdu IT reservoir water fill ON.
1.3.6.1.4.1.232.22.2.10.3.1.1.47ColumncpqRackCduApolloItWaterReservoirAirInletValveStatusOnread-onlymandatoryThis Cdu IT reservoir air inlet valve status ON.
1.3.6.1.4.1.232.22.2.10.3.1.1.48ColumncpqRackCduApolloItWaterReservoirAirInletValveSolenoidCutInSpread-onlymandatoryThis Cdu IT reservoir air inlet valve solenoid cut in setpoint.
1.3.6.1.4.1.232.22.2.10.3.1.1.49ColumncpqRackCduApolloItWaterReservoirAirInletValveSolenoidCutOutSpread-onlymandatoryThis Cdu IT reservoir air inlet valve solenoid cut out setpoint.
1.3.6.1.4.1.232.22.2.10.3.1.1.50ColumncpqRackCduApolloItWaterReservoirFlowread-onlymandatoryThis Cdu IT reservoir flow.
1.3.6.1.4.1.232.22.2.10.3.1.1.51ColumncpqRackCduApolloItWaterReservoirEnergyread-onlymandatoryThis Cdu IT reservoir energy.
1.3.6.1.4.1.232.22.3NodecpqRackSysObjID
1.3.6.1.4.1.232.22.3.1ScalarcpqRackSystemObjectIdentificationread-onlymandatoryThe hardware identification string. The string will reported by the rack firmware.
1.3.6.1.4.1.232.22.4NodecpqRackEventInfo
1.3.6.1.4.1.232.22.4.1ScalarcpqRackEventIndicationIdentifierread-onlymandatoryThe Event Indication Identifier.
1.3.6.1.4.1.232.22.4.2ScalarcpqRackEventIndicationTimeread-onlyoptionalThe Event Indication Time.
1.3.6.1.4.1.232.22.4.3ScalarcpqRackEventDescriptionread-onlyoptionalThe Event Description.
1.3.6.1.4.1.232.22.4.4ScalarcpqRackEventSummaryread-onlyoptionalShort description of the reason for the event.
1.3.6.1.4.1.232.22.4.5ScalarcpqRackEventCategoryread-onlyoptionalCategory for the event. This category is intended to be used by the consumer to group events.
1.3.6.1.4.1.232.22.4.6ScalarcpqRackOtherEventCategoryread-onlyoptionalA string defining other values for EventCategory. It is empty unless EventCategory value is other(1).
1.3.6.1.4.1.232.22.4.7ScalarcpqRackEventSubCategoryread-onlyoptionalSub-category for the event. This sub-category is intended to be used by the consumer in conjunction with the EventCategory to provide additional granularity to…
1.3.6.1.4.1.232.22.4.8ScalarcpqRackOtherEventSubCategoryread-onlyoptionalA string defining other values for EventSubCategory. It is empty unless EventSubCategory value is other(1)
1.3.6.1.4.1.232.22.4.9ScalarcpqRackEventThresholdread-onlyoptionalIdentifies the number of indications that need to occur as part of the internal provider throttling configured for this event.
1.3.6.1.4.1.232.22.4.10ScalarcpqRackEventTimeWinread-onlyoptionalIdentifies the time window during which the EventThreshold number of events need to occur as part of the internal provider throttling configured for this event…
1.3.6.1.4.1.232.22.4.11ScalarcpqRackEventActualThresholdread-onlyoptionalIdentifies the number of indications that have occurred to meet the internal provider throttling configured for this event.
1.3.6.1.4.1.232.22.4.12ScalarcpqRackEventActualTimeWinread-onlyoptionalIdentifies the time window during which the ActualEventThreshold number of events have occurred to meet the internal provider throttling configured for this ev…
1.3.6.1.4.1.232.22.4.13ScalarcpqRackEventProviderVersionread-onlyoptionalThe version of the provider generating this indication.
1.3.6.1.4.1.232.22.4.14ScalarcpqRackEventAlertingElementFormatread-onlyoptionalThe format of the AlertingManagedElement property is interpretable based upon the value of this property. Values are defined as: 1 - unknown. The format is unk…
1.3.6.1.4.1.232.22.4.15ScalarcpqRackEventOtherAlertingElementFormatread-onlyoptionalA string defining other values for AlertingElementFormat. It is empty unless cpqRackEventAlertingElementFormat value is other(1)
1.3.6.1.4.1.232.22.4.16ScalarcpqRackEventImpactedDomainread-onlyoptionalImpactedDomain is an enumerated value indicating the domain this event affects.
1.3.6.1.4.1.232.22.4.17ScalarcpqRackEventComplexNameread-onlyoptionalThe name of the complex.
1.3.6.1.4.1.232.22.4.18ScalarcpqRackEventPartitionIdread-onlyoptionalThe Unique Identifier for the Partition. The format of the partitionId will be of the form nparId:vparId.
1.3.6.1.4.1.232.22.4.19TablecpqRackEventTriggeringLogIDTablenot-accessibleoptionalA table of rack of Low Level LOG IDs.
1.3.6.1.4.1.232.22.4.19.1RowcpqRackEventTriggeringLogIDEntrynot-accessibleoptionalThe list of Low level LOG ID which were used to generate this event. The format of the value contained in this array is defined using the TriggeringLogIDFormat…
1.3.6.1.4.1.232.22.4.19.1.1ColumncpqRackEventTriggeringLogIDread-onlyoptionalA Low Lvevel LOG ID which were used to generate this event.
1.3.6.1.4.1.232.22.4.20ScalarcpqRackEventTriggeringLogIDFormatread-onlyoptionalThe format of the TriggeringLogID property which interpretable based upon the value of this property. Values are defined as: 1 - unknown. The format is unknown…
1.3.6.1.4.1.232.22.4.21ScalarcpqRackEventAlertTyperead-onlyoptionalThe event alert type.
1.3.6.1.4.1.232.22.4.22ScalarcpqRackEventOtherAlertTyperead-onlyoptionalThe event other alert type. It is empty unless cpqRackEventAlertType value is other.
1.3.6.1.4.1.232.22.4.23ScalarcpqRackEventProbableCauseread-onlyoptionalAn enumerated value that describes the probable cause of the error.
1.3.6.1.4.1.232.22.4.24ScalarcpqRackEventProbableCauseDescriptionread-onlyoptionalA free-form string describing the probable cause of the error.
1.3.6.1.4.1.232.22.4.25ScalarcpqRackEventPerceivedSeverityread-onlyoptionalAn enumerated value that describes the severity of the Indication from the point of view of the notifier.
1.3.6.1.4.1.232.22.4.26ScalarcpqRackEventOtherSeverityread-onlyoptionalOther perceived severity. It is empty unless cpqRackEventPerceivedSeverity value is other.
1.3.6.1.4.1.232.22.4.27ScalarcpqRackEventTrendingread-onlyoptionalThe event trending.
1.3.6.1.4.1.232.22.4.28ScalarcpqRackEventRecommendedActionsread-onlyoptionalA free-form string describing recommended actions to take to resolve the error.
1.3.6.1.4.1.232.22.4.29ScalarcpqRackEventIDread-onlyoptionalAn instrumentation or provider specific value that describes the underlying real-world event represented by the indication related to the not-OK status.
1.3.6.1.4.1.232.22.4.30ScalarcpqRackEventTimeread-onlyoptionalThe event time.
1.3.6.1.4.1.232.22.4.31ScalarcpqRackEventSystemCreationClassNameread-onlyoptionalThe event system creation class name.
1.3.6.1.4.1.232.22.4.32ScalarcpqRackEventSystemNameread-onlyoptionalThe event system name.
1.3.6.1.4.1.232.22.4.33ScalarcpqRackEventProviderNameread-onlyoptionalThe name of the Provider that generated the indication related to the not-OK status.
1.3.6.1.4.1.232.22001NodecpqRackNameChangedRack name has changed. This trap signifies that an agent or utility has changed the name of the rack. Each of the server blades in each of the enclosure within…
1.3.6.1.4.1.232.22002NodecpqRackEnclosureNameChangedThe enclosure name has changed. This trap signifies that an agent or utility has changed the name of an enclosure within the rack. Each of the components withi…
1.3.6.1.4.1.232.22003NodecpqRackEnclosureRemovedThe enclosure has been removed. This trap signifies that an enclosure has been removed from the rack. User Action: None.
1.3.6.1.4.1.232.22004NodecpqRackEnclosureInsertedThe enclosure has been inserted. This trap signifies that an enclosure has been inserted into the rack. User Action: None.
1.3.6.1.4.1.232.22005NodecpqRackEnclosureTempFailedThe enclosure temperature status has been set to failed. This trap signifies that a enclosure temperature sensor has been tripped indicating an overheat condit…
1.3.6.1.4.1.232.22006NodecpqRackEnclosureTempDegradedThe enclosure temperature status has been set to degraded. This trap signifies that an enclosure temperature sensor has been tripped indicating a possible over…
1.3.6.1.4.1.232.22007NodecpqRackEnclosureTempOkThe enclosure temperature status has been set to ok. This trap signifies that an enclosure temperature sensor has returned to normal. User Action: None.
1.3.6.1.4.1.232.22008NodecpqRackEnclosureFanFailedThe enclosure fan status has been set to failed. This trap signifies that an enclosure fan has failed and no other fans in the redundant fan group are operatin…
1.3.6.1.4.1.232.22009NodecpqRackEnclosureFanDegradedThe enclosure fan status has been set to degraded. This trap signifies that an enclosure fan has failed but other fans in the redundant fan group are still ope…
1.3.6.1.4.1.232.22010NodecpqRackEnclosureFanOkThe enclosure fan status has been set to ok. This trap signifies that an enclosure fan has returned to normal operation. User Action: None.
1.3.6.1.4.1.232.22011NodecpqRackEnclosureFanRemovedThe enclosure fan has been removed. User Action: None.
1.3.6.1.4.1.232.22012NodecpqRackEnclosureFanInsertedThe enclosure fan has been inserted. User Action: None.
1.3.6.1.4.1.232.22013NodecpqRackPowerSupplyFailedThe power supply status has been set to failed. This trap signifies that a power supply has failed. User Action: Replace the power supply as soon as possible.
1.3.6.1.4.1.232.22014NodecpqRackPowerSupplyDegradedThe power supply status has been set to degraded. This trap signifies that a power supply has degraded. User Action: Replace the power supply as soon as possib…
1.3.6.1.4.1.232.22015NodecpqRackPowerSupplyOkThe power supply status has been set to ok. This trap signifies that a power supply has returned to normal operation. User Action: None.
1.3.6.1.4.1.232.22016NodecpqRackPowerSupplyRemovedThe power supply has been removed. User Action: None.
1.3.6.1.4.1.232.22017NodecpqRackPowerSupplyInsertedThe power supply has been inserted. User Action: None.
1.3.6.1.4.1.232.22018NodecpqRackPowerSubsystemNotRedundantThe rack power subsystem is no longer in a redundant state. User Action: Replace any failed power supplies as soon as possible to return the system to a redund…
1.3.6.1.4.1.232.22019NodecpqRackPowerSubsystemLineVoltageProblemThe rack power supply detected an input line voltage problem. User Action: Check the power input for the power supply or replace any failed power supplies as s…
1.3.6.1.4.1.232.22020NodecpqRackPowerSubsystemOverloadConditionThe rack power subsystem overload condition. User Action: Replace any failed power supplies as soon as possible to return the system to a redundant state.
1.3.6.1.4.1.232.22021NodecpqRackPowerShedAutoShutdownServer shutdown due to power shedding. The server blade was shutdown due to a lack of power. User Action: Check power connections or add power supplies.
1.3.6.1.4.1.232.22022NodecpqRackServerPowerOnFailedNotRedundantServer power on prevented to preserve redundancy. There is not enough power to power on the server blade and maintain redundancy for the other blades in the en…
1.3.6.1.4.1.232.22023NodecpqRackServerPowerOnFailedNotEnoughPowerInadequate power to power on. There is not enough power to power on the server blade. User Action: Check power connections or add power supplies.
1.3.6.1.4.1.232.22024NodecpqRackServerPowerOnFailedEnclosureNotFoundInadequate power to power on. There is not enough power to power on the server blade. The server enclosure micro-controller was not found. User Action: Check s…
1.3.6.1.4.1.232.22025NodecpqRackServerPowerOnFailedPowerChassisNotFoundInadequate power to power on. There is not enough power to power on the server blade. The power enclosure micro-controller was not found. User Action: Check po…
1.3.6.1.4.1.232.22026NodecpqRackServerPowerOnManualOverrideServer power on via manual override. The server blade was powered on by a manual override. User Action: None.
1.3.6.1.4.1.232.22027NodecpqRackFuseOpenFuse open. The fuse has been tripped. User Action: Check enclosure and / or blade power connections and reset the fuse.
1.3.6.1.4.1.232.22028NodecpqRackServerBladeRemovedServer blade removed. The server blade has been removed from the enclosure. User Action: None.
1.3.6.1.4.1.232.22029NodecpqRackServerBladeInsertedServer blade inserted. The server blade has been inserted into the enclosure. User Action: None.
1.3.6.1.4.1.232.22030NodecpqRackPowerChassisNotLoadBalancedPower subsystem not load balanced. The power subsystem is out of balance for this power enclosure. User Action: Check the power enclosure and power supplies. R…
1.3.6.1.4.1.232.22031NodecpqRackPowerChassisDcPowerProblemPower subsystem DC power problem. There is a power subsystem DC power problem for this power enclosure. User Action: Check the power enclosure and power suppli…
1.3.6.1.4.1.232.22032NodecpqRackPowerChassisAcFacilityPowerExceededPower subsystem AC facility input power exceeded. There is a power subsystem Power subsystem AC facility input power exceeded for this power enclosure. User Ac…
1.3.6.1.4.1.232.22033NodecpqRackPowerUnknownPowerConsumptionUnknown power consumption. There is an unknown power consumer drawing power. User Action: Check the power enclosure and power supplies. Replace any failed or d…
1.3.6.1.4.1.232.22034NodecpqRackPowerChassisLoadBalancingWireMissingPower subsystem load balancing wire missing. The power subsystem load balancing wire missing. User Action: Connect the load balancing wire.
1.3.6.1.4.1.232.22035NodecpqRackPowerChassisTooManyPowerChassisPower subsystem has too may power enclosures. The maximum number of power enclosures has been exceeded. User Action: Remove the extra power enclosure.
1.3.6.1.4.1.232.22036NodecpqRackPowerChassisConfigErrorPower subsystem improperly configured. The power subsystem has been improperly configured. User Action: Check the cabling of the power enclosure.
1.3.6.1.4.1.232.22037NodecpqRackEnclosureManagerDegradedThe Onboard Administrator or other management processor status has been set to degraded. This trap signifies that either the Onboard Administrator(s) or its co…
1.3.6.1.4.1.232.22038NodecpqRackEnclosureManagerOkThe Onboard Administrator or other management processor's status has been set to ok. This trap signifies that an Onboard Administrator or other management proc…
1.3.6.1.4.1.232.22039NodecpqRackEnclosureManagerRemovedThe Onboard Administrator has been removed. User Action: None.
1.3.6.1.4.1.232.22040NodecpqRackEnclosureManagerInsertedThe Onboard Administrator or other management processor has been inserted. User Action: None.
1.3.6.1.4.1.232.22041NodecpqRackManagerPrimaryRoleThe Onboard Administrator or other management processor has taken the role of primary. User Action: None.
1.3.6.1.4.1.232.22042NodecpqRackServerBladeEKeyingFailedThe server blade e-keying has failed. This trap signifies that a server blade e-keying has failed and there is a port mapping problem between a server mezz car…
1.3.6.1.4.1.232.22043NodecpqRackServerBladeEKeyingOKThe server blade e-keying is ok. This trap signifies that a server blade e-keying has returned to normal operation. User Action: None.
1.3.6.1.4.1.232.22044NodecpqRackNetConnectorRemovedInterconnect removed. The interconnect has been removed from the enclosure. User Action: None.
1.3.6.1.4.1.232.22045NodecpqRackNetConnectorInsertedInterconnect inserted. The interconnect has been inserted into the enclosure. User Action: None.
1.3.6.1.4.1.232.22046NodecpqRackNetConnectorFailedThe interconnect status has been set to failed. This trap signifies that a interconnect has failed. User Action: Replace the interconnect as soon as possible.
1.3.6.1.4.1.232.22047NodecpqRackNetConnectorDegradedThe interconnect status has been set to degraded. This trap signifies that a interconnect has degraded. User Action: Refer to the OA and the status diagnostics…
1.3.6.1.4.1.232.22048NodecpqRackNetConnectorOkThe interconnect status has been set to ok. This trap signifies that a interconnect has returned to normal operation. User Action: None.
1.3.6.1.4.1.232.22049NodecpqRackServerBladeToLowPowerThe server blade requested to low power. User Action: None.
1.3.6.1.4.1.232.22050NodecpqRackServerBladeRemoved2Server blade removed. The server blade has been removed from the enclosure. User Action: None.
1.3.6.1.4.1.232.22051NodecpqRackServerBladeInserted2Server blade inserted. The server blade has been inserted into the enclosure. User Action: None.
1.3.6.1.4.1.232.22052NodecpqRackServerBladeStatusRepairedServer blade repaired. The server blade status has changed to OK. User Action: None.
1.3.6.1.4.1.232.22053NodecpqRackServerBladeStatusDegradedServer blade health status Degraded. The server blade health status has changed to Degraded. User Action: Check blade server and enclosure SYSLOG.
1.3.6.1.4.1.232.22054NodecpqRackServerBladeStatusCriticalServer blade health status Critical. The server blade health status has changed to Critical. User Action: Check blade server and enclosure SYSLOG.
1.3.6.1.4.1.232.22055NodecpqRackServerBladeGrpCapTimeoutThe server blade is not responding to the group capper. The server blade is not responding to capping requests from the enclosure group capper User Action: Res…
1.3.6.1.4.1.232.22056NodecpqRackServerBladeUnexpectedShutdownServer blade shutdown unexpectadly. An unexpected shutdown event has occurred for this server blade. User Action: Check blade server and enclosure SYSLOG.
1.3.6.1.4.1.232.22057NodecpqRackServerBladeMangementControllerFirmwareUpdatingServer blade's management controller firmware updating. This server blade's management controller has started updating it's firmware. User Action: None.
1.3.6.1.4.1.232.22058NodecpqRackServerBladeMangementControllerFirmwareUpdateCompleteServer blade's management controller firmware update has completed. This server blade's management controller has finished updating it's firmware. User Action:…
1.3.6.1.4.1.232.22059NodecpqRackServerBladeSystemBIOSFirmwareUpdatingServer blade's system BIOS firmware updating. This server blade's system BIOS has started updating. User Action: None.
1.3.6.1.4.1.232.22060NodecpqRackServerBladeSystemBIOSFirmwareUpdateCompletedServer blade's system BIOS firmware update complete. This server blade's system BIOS has completed updating. User Action: None.
1.3.6.1.4.1.232.22061NodecpqRackServerBladeFrontIOBlankingActiveServer blade has disabled front IO ports. Front IO blanking status has changed to active for this server blade. User Action: None.
1.3.6.1.4.1.232.22062NodecpqRackServerBladeRemoteFrontIOBlankingInactiveServer blade has front IO blanking mode now inactive. Front IO blanking status has changed to inactive for this server blade. User Action: None.
1.3.6.1.4.1.232.22063NodecpqRackServerBladeDiagnosticAdaptorInsertedServer blade diagnostic adaptor inserted. Blade diagnostic adaptor status has changed to inserted for this server blade. User Action: None.
1.3.6.1.4.1.232.22064NodecpqRackServerBladeDiagnosticAdaptorRemovedServer blade diagnostic adaptor removed. Blade diagnostic adaptor status has changed to removed for this server blade. User Action: None.
1.3.6.1.4.1.232.22065NodecpqRackServerBladeEnteredPXEBootModeServer blade has entered PXE Boot Mode. Server blade Pre-Boot-eXecution (PXE) Mode started. User Action: None.
1.3.6.1.4.1.232.22066NodecpqRackServerBladeExitedPXEBootModeServer blade has exited PXE Boot Mode. Server blade Pre-Boot-eXecution (PXE) Mode exited. User Action: None.
1.3.6.1.4.1.232.22067NodecpqRackServerBladeWarmResetServer blade has been warm reset. Server blade has experienced a warm reset. User Action: None.
1.3.6.1.4.1.232.22068NodecpqRackServerBladePOSTCompletedServer blade system BIOS POST complete. Server blade has completed system BIOS Power-On-Self-Test (POST). User Action: None.
1.3.6.1.4.1.232.22069NodecpqRackServerBladePoweredOnServer blade has powered on. User Action: None.
1.3.6.1.4.1.232.22070NodecpqRackServerBladePoweredOffServer blade has powered off. User Action: None.
1.3.6.1.4.1.232.22071NodecpqRackInformationalEAETrapEAE Informational trap
1.3.6.1.4.1.232.22072NodecpqRackMinorEAETrapEAE Minor trap
1.3.6.1.4.1.232.22073NodecpqRackMajorEAETrapEAE Major trap
1.3.6.1.4.1.232.22074NodecpqRackCriticalEAETrapEAE Critical trap
1.3.6.1.4.1.232.22075NodecpqRackPowerMinorEAETrapFlexFabric Cmdr Power Subsystem Minor trap. User Action: For FlexFabric Cmdr, please refer to product documentation for possible corrective actions.
1.3.6.1.4.1.232.22076NodecpqRackPowerMajorEAETrapFlexFabric Cmdr Power Subsystem Major trap. User Action: For FlexFabric Cmdr, please refer to product documentation for possible corrective actions.
1.3.6.1.4.1.232.22077NodecpqRackPowerCriticalEAETrapFlexFabric Cmdr Power Subsystem Critical trap. User Action: For FlexFabric Cmdr, please refer to product documentation for possible corrective actions.
1.3.6.1.4.1.232.22078NodecpqRackServerBladePartitionChangeServer Blade Partition Changed trap. The server blade is part of a conjoined blade and its partition has changed. User Action: None.
1.3.6.1.4.1.232.22079NodecpqRackInformationalWSMANTrapWSMAN Informational trap
1.3.6.1.4.1.232.22080NodecpqRackMinorWSMANTrapWSMAN Minor trap
1.3.6.1.4.1.232.22081NodecpqRackMajorWSMANTrapWSMAN Major trap
1.3.6.1.4.1.232.22082NodecpqRackCriticalWSMANTrapWSMAN Critical trap
1.3.6.1.4.1.232.22083NodecpqRackEnclosureManagerLinkDownThe Onboard Administrator Network Link is Down. The Onboard Administrator firmware has detected the loss of network link. User Action: Check network connection…
1.3.6.1.4.1.232.22084NodecpqRackEnclosureManagerLinkUpThe Onboard Administrator Network Link is Up. The Onboard Administrator firmware has detected the presence of network link. User Action: None.
1.3.6.1.4.1.232.22085NodecpqRackErsCommFailureThe Onboard Administrator to Insight Remote Support or Insight Online communication failed. User Action: Please check the connectivity to Insight Remote Suppor…
1.3.6.1.4.1.232.22086NodecpqRackPowerSubsystemOverloadConditionRepairedThe rack power subsystem overload condition repaired.
1.3.6.1.4.1.232.22087NodecpqRackPowerSubsystemRedundancyOkThe rack power subsystem is now redundant. This trap signifies that the enclosure power subsystem redundancy is now restored. User Action : None.
1.3.6.1.4.1.232.22088NodecpqRackNetConnectorTempDegradedThe Interconnect temperature status has been set to degraded. This trap signifies that an interconnect temperature sensor has been tripped indicating a possibl…
1.3.6.1.4.1.232.22089NodecpqRackNetConnectorTempOkThe interconnect temperature status has been set to ok. This trap signifies that an interconnect temperature sensor has returned to normal. User Action: None.
1.3.6.1.4.1.232.22090NodecpqRackEnvironmentalLeakDetectedA leak was detected by one or more leak detect sensors in the rack
1.3.6.1.4.1.232.22091NodecpqRackEnvironmentalDoorStateA door has been opened or closed in the rack
1.3.6.1.4.1.232.22092NodecpqRackEnvironmentalAirTempSensorAir temperature sensor warning condition
1.3.6.1.4.1.232.22093NodecpqRackEnvironmentalControlValveStatusWater control valve status
1.3.6.1.4.1.232.22094NodecpqRackEnvironmentalWaterTempThresholdExceededWater Temperature Threshold exceeded
1.3.6.1.4.1.232.22095NodecpqRackEnvironmentalFlowSensorStatusFlow sensor status
1.3.6.1.4.1.232.22096NodecpqRackEnvironmentalWaterPressureThresholdExceededWater pressure threshold exceeded
1.3.6.1.4.1.232.22097NodecpqRackEnvironmentalAutomaticRapidPowerOffAn Automatic Rapid Power Off (ARPO) event occured
1.3.6.1.4.1.232.22098NodecpqRackEnvironmentalRopeLeakDetectorEventRope leak detector event
1.3.6.1.4.1.232.22099NodecpqRackEnvironmentalTemperatureThresholdExceededEnvironmental Controller on board temperature sensor exceeded threshold
1.3.6.1.4.1.232.22100NodecpqRackEnvironmentalHumidityThresholdExceededEnvironmental Controller on board temperature sensor exceeded threshold
1.3.6.1.4.1.232.22101NodecpqRackEnvironmentalControllerOnBoardBatteryEnvironmental controller on board Battery is low
1.3.6.1.4.1.232.22102NodecpqRackEnvironmentalControllerAPMCommunicationFailureCommuncations between Apollo Platform Manager (APM) and the environmental controller failed
1.3.6.1.4.1.232.22103NodecpqRackEnvironmentalLeakDetectedCriticalA leak was detected by one or more leak detect sensors in the rack
1.3.6.1.4.1.232.22104NodecpqRackPowerSubsystemReductionModeActivateAll rack power supplies in a bank detected input voltage problem and power reduction mode activated in the enclosure. User Action : None.
1.3.6.1.4.1.232.22105NodecpqRackPowerSubsystemReductionModeDeactivateThe power reduction mode deactivated in the enclosure. User Action : None.