CPQRACK-MIB
558 objects
No module-level DESCRIPTION found.
Imported Objects
| CPQHOST-MIB | compaq cpqHoOsType cpqHoTrapFlags cpqHoVersion |
| RFC-1212 | OBJECT-TYPE |
| RFC-1215 | TRAP-TYPE |
| RFC1213-MIB | DisplayString sysName |
| OID | Name | Access | Status | Description |
|---|---|---|---|---|
| 1.3.6.1.4.1.232.22 | NodecpqRackInfo | |||
| 1.3.6.1.4.1.232.22.1 | NodecpqRackMibRev | |||
| 1.3.6.1.4.1.232.22.1.1 | ScalarcpqRackMibRevMajor | read-only | mandatory | The major revision level of the MIB. A change in the major revision level represents a major change in the architecture of the MIB. A change in the major revis… |
| 1.3.6.1.4.1.232.22.1.2 | ScalarcpqRackMibRevMinor | read-only | mandatory | The minor revision level of the MIB. A change in the minor revision level may represent some minor additional support, no changes to any pre-existing informati… |
| 1.3.6.1.4.1.232.22.1.3 | ScalarcpqRackMibCondition | read-only | mandatory | The overall condition. This object represents the overall status of the rack information represented by this MIB. |
| 1.3.6.1.4.1.232.22.2 | NodecpqRackComponent | |||
| 1.3.6.1.4.1.232.22.2.1 | NodecpqRackInterface | |||
| 1.3.6.1.4.1.232.22.2.1.4 | NodecpqRackOsCommon | |||
| 1.3.6.1.4.1.232.22.2.1.4.1 | ScalarcpqRackOsCommonPollFreq | read-write | mandatory | The Management Agent's polling frequency. The frequency, in seconds, at which the Agent requests information from the device driver. A frequency of zero (0) in… |
| 1.3.6.1.4.1.232.22.2.2 | NodecpqRackAsset | |||
| 1.3.6.1.4.1.232.22.2.2.1 | TablecpqRackAssetTable | not-accessible | mandatory | A table of rack asset information. |
| 1.3.6.1.4.1.232.22.2.2.1.1 | RowcpqRackAssetEntry | not-accessible | mandatory | A rack asset description. |
| 1.3.6.1.4.1.232.22.2.2.1.1.1 | ColumncpqRackAssetIndex | read-only | mandatory | A number that uniquely specifies this rack table entry. |
| 1.3.6.1.4.1.232.22.2.2.1.1.2 | ColumncpqRackName | read-only | mandatory | The customer changeable identifier used to identify the entire rack. The string will be empty if the system does not report this function. |
| 1.3.6.1.4.1.232.22.2.2.1.1.3 | ColumncpqRackUid | read-only | mandatory | The rack unique identifier. The string will be empty if the rack does not report the UID or if it could not be determined. |
| 1.3.6.1.4.1.232.22.2.2.1.1.4 | ColumncpqRackSerialNum | read-only | mandatory | The rack serial number. The string will be empty if the rack does not report the serial number. |
| 1.3.6.1.4.1.232.22.2.2.1.1.5 | ColumncpqRackTrapSequenceNum | read-only | mandatory | The trap sequence number for rack traps. This is used by the management application trap processing. This will be -1 if the rack does not report the informatio… |
| 1.3.6.1.4.1.232.22.2.2.1.1.6 | ColumncpqRackHeight | read-only | mandatory | The internal height dimension of the useable rack space expressed in millimeters. This will be -1 if the rack does not report the information or it could not b… |
| 1.3.6.1.4.1.232.22.2.2.1.1.7 | ColumncpqRackWidth | read-only | mandatory | The internal width dimension of the useable rack space expressed in millimeters. This will be -1 if the rack does not report the information or it could not be… |
| 1.3.6.1.4.1.232.22.2.2.1.1.8 | ColumncpqRackDepth | read-only | mandatory | The internal depth dimension of the useable rack space expressed in millimeters. This will be -1 if the rack does not report the information or it could not be… |
| 1.3.6.1.4.1.232.22.2.3 | NodecpqRackEnclosure | |||
| 1.3.6.1.4.1.232.22.2.3.1 | NodecpqRackCommonEnclosure | |||
| 1.3.6.1.4.1.232.22.2.3.1.1 | TablecpqRackCommonEnclosureTable | not-accessible | mandatory | A table of rack enclosure information. |
| 1.3.6.1.4.1.232.22.2.3.1.1.1 | RowcpqRackCommonEnclosureEntry | not-accessible | mandatory | A rack enclosure description. |
| 1.3.6.1.4.1.232.22.2.3.1.1.1.1 | ColumncpqRackCommonEnclosureRack | read-only | mandatory | A number that uniquely specifies this rack. |
| 1.3.6.1.4.1.232.22.2.3.1.1.1.2 | ColumncpqRackCommonEnclosureIndex | read-only | mandatory | A number that uniquely specifies this enclosure in the rack. |
| 1.3.6.1.4.1.232.22.2.3.1.1.1.3 | ColumncpqRackCommonEnclosureModel | read-only | mandatory | The model name of the enclosure. The string will be empty if the enclosure does not report the model information. |
| 1.3.6.1.4.1.232.22.2.3.1.1.1.4 | ColumncpqRackCommonEnclosureAssetTag | read-only | mandatory | The customer changeable asset identifier of the enclosure. The string will be empty if the system does not report this function or if the asset tag has not bee… |
| 1.3.6.1.4.1.232.22.2.3.1.1.1.5 | ColumncpqRackCommonEnclosurePartNumber | read-only | mandatory | The part number of the enclosure. The string will be empty if the enclosure does not report this function. |
| 1.3.6.1.4.1.232.22.2.3.1.1.1.6 | ColumncpqRackCommonEnclosureSparePartNumber | read-only | mandatory | The spare part number of the enclosure. The string will be empty if the enclosure does not report this function. |
| 1.3.6.1.4.1.232.22.2.3.1.1.1.7 | ColumncpqRackCommonEnclosureSerialNum | read-only | mandatory | The serial number of the enclosure. The string will be empty if the enclosure does not report the serial number. |
| 1.3.6.1.4.1.232.22.2.3.1.1.1.8 | ColumncpqRackCommonEnclosureFWRev | read-only | mandatory | The firmware revision of the enclosure. The string will be empty if the enclosure does not report the firmware revision or does not contain firmware. |
| 1.3.6.1.4.1.232.22.2.3.1.1.1.9 | ColumncpqRackCommonEnclosureName | read-only | mandatory | The name of the enclosure. The string will be empty if the enclosure does not report the name or it could not be determined. |
| 1.3.6.1.4.1.232.22.2.3.1.1.1.10 | ColumncpqRackCommonEnclosureNeighborNamePrev | read-only | mandatory | The name of the enclosure immediately preceding or above this enclosure. The string will be empty if the neighbor enclosure name could not be determined or the… |
| 1.3.6.1.4.1.232.22.2.3.1.1.1.11 | ColumncpqRackCommonEnclosureNeighborNameNext | read-only | mandatory | The name of the enclosure immediately following or below this enclosure. The string will be empty if the neighbor enclosure name could not be determined or the… |
| 1.3.6.1.4.1.232.22.2.3.1.1.1.12 | ColumncpqRackCommonEnclosureHeight | read-only | mandatory | The height dimension of the rack space taken by the enclosure expressed in millimeters. This will be -1 if the rack does not report the information or it could… |
| 1.3.6.1.4.1.232.22.2.3.1.1.1.13 | ColumncpqRackCommonEnclosureWidth | read-only | mandatory | The width dimension of the rack space taken by the enclosure expressed in millimeters. This will be -1 if the rack does not report the information or it could … |
| 1.3.6.1.4.1.232.22.2.3.1.1.1.14 | ColumncpqRackCommonEnclosureDepth | read-only | mandatory | The depth dimension of the rack space taken by the enclosure expressed in millimeters. This will be -1 if the rack does not report the information or it could … |
| 1.3.6.1.4.1.232.22.2.3.1.1.1.15 | ColumncpqRackCommonEnclosureTrapSequenceNum | read-only | mandatory | The trap sequence number for the enclosure. This is used by the management application trap processing. This will be -1 if the rack does not report the informa… |
| 1.3.6.1.4.1.232.22.2.3.1.1.1.16 | ColumncpqRackCommonEnclosureCondition | read-only | mandatory | The overall condition of the enclosure. This is the aggregate of the temperature sensors, fans, and fuses within the enclosure. This value will be one of the f… |
| 1.3.6.1.4.1.232.22.2.3.1.1.1.17 | ColumncpqRackCommonEnclosureHasServerBlades | read-only | mandatory | The enclosure can contain server blades. This will be true(2) is the enclosure can house server blades. The cpqRackServerEnclosureTable will contain server enc… |
| 1.3.6.1.4.1.232.22.2.3.1.1.1.18 | ColumncpqRackCommonEnclosureHasPowerSupplies | read-only | mandatory | The enclosure can contain power supplies. This will be true(2) is the enclosure can house power supplies. The cpqRackEnclosurePowerTable will contain power enc… |
| 1.3.6.1.4.1.232.22.2.3.1.1.1.19 | ColumncpqRackCommonEnclosureHasNetConnectors | read-only | mandatory | The enclosure contains network connectivity. This will be true(2) is the enclosure contains network connectivity. The cpqRackCommonEnclosureNetConnectorTable w… |
| 1.3.6.1.4.1.232.22.2.3.1.1.1.20 | ColumncpqRackCommonEnclosureHasTempSensors | read-only | mandatory | The enclosure contains temperature sensors. This will be true(2) is the enclosure contains temperature sensors. The cpqRackCommonEnclosureTempTable will contai… |
| 1.3.6.1.4.1.232.22.2.3.1.1.1.21 | ColumncpqRackCommonEnclosureHasFans | read-only | mandatory | The enclosure contains fans. This will be true(2) is the enclosure contains fans. The cpqRackCommonEnclosureFanTable will contain the fan specific information.… |
| 1.3.6.1.4.1.232.22.2.3.1.1.1.22 | ColumncpqRackCommonEnclosureHasFuses | read-only | mandatory | The enclosure contains fuses. This will be true(2) is the enclosure contains fuses. The cpqRackCommonEnclosureFuseTable will contain the fuse specific informat… |
| 1.3.6.1.4.1.232.22.2.3.1.1.1.23 | ColumncpqRackCommonEnclosureMgmtUID | read-write | mandatory | The Unit Identifier LED. This value will be one of the following: other(1) The state of the LED could not be determined. Setting the LED state is not allowed. … |
| 1.3.6.1.4.1.232.22.2.3.1.1.1.24 | ColumncpqRackCommonEnclosureSerialNumPrev | read-only | mandatory | The serial number of the enclosure immediately preceding or above this enclosure. The string will be empty if the neighbor enclosure serial number could not be… |
| 1.3.6.1.4.1.232.22.2.3.1.1.1.25 | ColumncpqRackCommonEnclosureSerialNumNext | read-only | mandatory | The serial number of the enclosure immediately following or below this enclosure. The string will be empty if the neighbor enclosure serial number could not be… |
| 1.3.6.1.4.1.232.22.2.3.1.1.1.26 | ColumncpqRackCommonEnclosureAddress | read-only | mandatory | The unique address of the enclosure within the rack. This will be -1 if the rack does not report the information or it could not be determined. |
| 1.3.6.1.4.1.232.22.2.3.1.1.1.27 | ColumncpqRackCommonEnclosureProductId | read-only | mandatory | The product id string of the enclosure. The string will be empty if the enclosure does not report the product id string. |
| 1.3.6.1.4.1.232.22.2.3.1.1.1.28 | ColumncpqRackCommonEnclosureProductIdPrev | read-only | mandatory | The product id string of the enclosure immediately preceding or above this enclosure. The string will be empty if the enclosure does not report the product id … |
| 1.3.6.1.4.1.232.22.2.3.1.1.1.29 | ColumncpqRackCommonEnclosureProductIdNext | read-only | mandatory | The product id string of the enclosure immediately following or below this enclosure. The string will be empty if the enclosure does not report the product id … |
| 1.3.6.1.4.1.232.22.2.3.1.1.1.30 | ColumncpqRackCommonEnclosureUUID | read-only | mandatory | The universal unique identifier string of the enclosure. The string will be empty if the enclosure does not report the UUID string. |
| 1.3.6.1.4.1.232.22.2.3.1.1.1.31 | ColumncpqRackCommonEnclosureUUIDPrev | read-only | mandatory | The universal unique identifier string of the enclosure immediately preceding or above this enclosure. The string will be empty if the enclosure does not repor… |
| 1.3.6.1.4.1.232.22.2.3.1.1.1.32 | ColumncpqRackCommonEnclosureUUIDNext | read-only | mandatory | The universal unique identifier string of the enclosure immediately following or below this enclosure. The string will be empty if the enclosure does not repor… |
| 1.3.6.1.4.1.232.22.2.3.1.1.1.33 | ColumncpqRackCommonEnclosureHasManagers | read-only | mandatory | The enclosure contains managers. This will be true(2) is the enclosure contains managers. The cpqRackCommonEnclosureManagerTable will contain the manager speci… |
| 1.3.6.1.4.1.232.22.2.3.1.2 | TablecpqRackCommonEnclosureTempTable | not-accessible | mandatory | A table of rack enclosure temperature sensor information. |
| 1.3.6.1.4.1.232.22.2.3.1.2.1 | RowcpqRackCommonEnclosureTempEntry | not-accessible | mandatory | A rack enclosure temperature sensor description. |
| 1.3.6.1.4.1.232.22.2.3.1.2.1.1 | ColumncpqRackCommonEnclosureTempRack | read-only | mandatory | A number that uniquely specifies this rack. |
| 1.3.6.1.4.1.232.22.2.3.1.2.1.2 | ColumncpqRackCommonEnclosureTempChassis | read-only | mandatory | A number that uniquely specifies this enclosure in the rack. |
| 1.3.6.1.4.1.232.22.2.3.1.2.1.3 | ColumncpqRackCommonEnclosureTempSensorIndex | read-only | mandatory | A number that uniquely specifies this temperature sensor within this enclosure in the rack. |
| 1.3.6.1.4.1.232.22.2.3.1.2.1.4 | ColumncpqRackCommonEnclosureTempSensorEnclosureName | read-only | mandatory | The name of the enclosure. The string will be empty if the enclosure does not report the name or it could not be determined. |
| 1.3.6.1.4.1.232.22.2.3.1.2.1.5 | ColumncpqRackCommonEnclosureTempLocation | read-only | mandatory | The location description of the temperature sensor within the enclosure. The string will be empty if the location could not be determined. |
| 1.3.6.1.4.1.232.22.2.3.1.2.1.6 | ColumncpqRackCommonEnclosureTempCurrent | read-only | mandatory | This is the current temperature sensor reading in degrees celsius. If this value cannot be determined by software, then a value of -1 will be returned. |
| 1.3.6.1.4.1.232.22.2.3.1.2.1.7 | ColumncpqRackCommonEnclosureTempThreshold | read-only | mandatory | This is the threshold temperature sensor setting in degrees celsius. This is the temperature in which the sensor will be considered to be in a tripped state th… |
| 1.3.6.1.4.1.232.22.2.3.1.2.1.8 | ColumncpqRackCommonEnclosureTempCondition | read-only | mandatory | The Temperature sensor condition. This value will be one of the following: other(1) Temperature could not be determined. ok(2) The temperature sensor is within… |
| 1.3.6.1.4.1.232.22.2.3.1.2.1.9 | ColumncpqRackCommonEnclosureTempType | read-only | mandatory | This specifies the type of this instance of temperature sensor. This value will be one of the following: other(1) Temperature threshold type could not be deter… |
| 1.3.6.1.4.1.232.22.2.3.1.2.1.10 | ColumncpqRackCommonEnclosureTempSensorEnclosureSerialNum | read-only | mandatory | The serial number of the enclosure containing this temperature sensor. The string will be empty if the enclosure does not report the serial number or it could … |
| 1.3.6.1.4.1.232.22.2.3.1.3 | TablecpqRackCommonEnclosureFanTable | not-accessible | mandatory | A table of rack enclosure fan information. |
| 1.3.6.1.4.1.232.22.2.3.1.3.1 | RowcpqRackCommonEnclosureFanEntry | not-accessible | mandatory | A rack enclosure fan description. |
| 1.3.6.1.4.1.232.22.2.3.1.3.1.1 | ColumncpqRackCommonEnclosureFanRack | read-only | mandatory | A number that uniquely specifies this rack. |
| 1.3.6.1.4.1.232.22.2.3.1.3.1.2 | ColumncpqRackCommonEnclosureFanChassis | read-only | mandatory | A number that uniquely specifies this enclosure in the rack. |
| 1.3.6.1.4.1.232.22.2.3.1.3.1.3 | ColumncpqRackCommonEnclosureFanIndex | read-only | mandatory | A number that uniquely specifies this fan within this enclosure in the rack. |
| 1.3.6.1.4.1.232.22.2.3.1.3.1.4 | ColumncpqRackCommonEnclosureFanEnclosureName | read-only | mandatory | The name of the enclosure. The string will be empty if the enclosure does not report the name or it could not be determined. |
| 1.3.6.1.4.1.232.22.2.3.1.3.1.5 | ColumncpqRackCommonEnclosureFanLocation | read-only | mandatory | The location description of the fan within the enclosure. The string will be empty if the location could not be determined. |
| 1.3.6.1.4.1.232.22.2.3.1.3.1.6 | ColumncpqRackCommonEnclosureFanPartNumber | read-only | mandatory | The part number of the enclosure fan. The string will be empty if the part number could not be determined. |
| 1.3.6.1.4.1.232.22.2.3.1.3.1.7 | ColumncpqRackCommonEnclosureFanSparePartNumber | read-only | mandatory | The spare part number of the enclosure fan. The string will be empty if the part number could not be determined. |
| 1.3.6.1.4.1.232.22.2.3.1.3.1.8 | ColumncpqRackCommonEnclosureFanPresent | read-only | mandatory | This specifies if the fan described is present in the system. |
| 1.3.6.1.4.1.232.22.2.3.1.3.1.9 | ColumncpqRackCommonEnclosureFanRedundant | read-only | mandatory | This specifies if the fan is in a redundant configuration. |
| 1.3.6.1.4.1.232.22.2.3.1.3.1.10 | ColumncpqRackCommonEnclosureFanRedundantGroupId | read-only | mandatory | This specifies the group number for redundant fans within this enclosure. |
| 1.3.6.1.4.1.232.22.2.3.1.3.1.11 | ColumncpqRackCommonEnclosureFanCondition | read-only | mandatory | The condition of the fan. This value will be one of the following: other(1) Fan status detection is not supported. ok(2) The fan is operating properly. degrade… |
| 1.3.6.1.4.1.232.22.2.3.1.3.1.12 | ColumncpqRackCommonEnclosureFanEnclosureSerialNum | read-only | mandatory | The serial number of the enclosure containing the fan. The string will be empty if the enclosure does not report the serial number or it could not be determine… |
| 1.3.6.1.4.1.232.22.2.3.1.4 | TablecpqRackCommonEnclosureFuseTable | not-accessible | mandatory | A table of rack enclosure fuse information. |
| 1.3.6.1.4.1.232.22.2.3.1.4.1 | RowcpqRackCommonEnclosureFuseEntry | not-accessible | mandatory | A rack enclosure fuse description. |
| 1.3.6.1.4.1.232.22.2.3.1.4.1.1 | ColumncpqRackCommonEnclosureFuseRack | read-only | mandatory | A number that uniquely specifies this rack. |
| 1.3.6.1.4.1.232.22.2.3.1.4.1.2 | ColumncpqRackCommonEnclosureFuseChassis | read-only | mandatory | A number that uniquely specifies this enclosure in the rack. |
| 1.3.6.1.4.1.232.22.2.3.1.4.1.3 | ColumncpqRackCommonEnclosureFuseIndex | read-only | mandatory | A number that uniquely specifies the fuse within this enclosure. |
| 1.3.6.1.4.1.232.22.2.3.1.4.1.4 | ColumncpqRackCommonEnclosureFuseEnclosureName | read-only | mandatory | The name of the enclosure. The string will be empty if the enclosure does not report the name or it could not be determined. |
| 1.3.6.1.4.1.232.22.2.3.1.4.1.5 | ColumncpqRackCommonEnclosureFuseLocation | read-only | mandatory | The location description of the fuse within the enclosure. The string will be empty if the location could not be determined. |
| 1.3.6.1.4.1.232.22.2.3.1.4.1.6 | ColumncpqRackCommonEnclosureFusePresent | read-only | mandatory | This specifies if the fuse described is present in the system. |
| 1.3.6.1.4.1.232.22.2.3.1.4.1.7 | ColumncpqRackCommonEnclosureFuseCondition | read-only | mandatory | The condition of the fuse. This value will be one of the following: other(1) Fuse status detection is not supported. ok(2) The fuse is operating properly. fail… |
| 1.3.6.1.4.1.232.22.2.3.1.5 | TablecpqRackCommonEnclosureFruTable | not-accessible | mandatory | A table of rack enclosure field replaceable units information. |
| 1.3.6.1.4.1.232.22.2.3.1.5.1 | RowcpqRackCommonEnclosureFruEntry | not-accessible | mandatory | A rack enclosure field replaceable unit description. |
| 1.3.6.1.4.1.232.22.2.3.1.5.1.1 | ColumncpqRackCommonEnclosureFruRack | read-only | mandatory | A number that uniquely specifies this rack. |
| 1.3.6.1.4.1.232.22.2.3.1.5.1.2 | ColumncpqRackCommonEnclosureFruChassis | read-only | mandatory | A number that uniquely specifies this enclosure in the rack. |
| 1.3.6.1.4.1.232.22.2.3.1.5.1.3 | ColumncpqRackCommonEnclosureFruIndex | read-only | mandatory | A number that uniquely specifies the FRU within this enclosure. |
| 1.3.6.1.4.1.232.22.2.3.1.5.1.4 | ColumncpqRackCommonEnclosureFruEnclosureName | read-only | mandatory | The name of the enclosure. The string will be empty if the enclosure does not report the name or it could not be determined. |
| 1.3.6.1.4.1.232.22.2.3.1.5.1.5 | ColumncpqRackCommonEnclosureFruDescription | read-only | mandatory | A description of the FRU component. The string will be empty if the enclosure does not report the description information. |
| 1.3.6.1.4.1.232.22.2.3.1.5.1.6 | ColumncpqRackCommonEnclosureFruLocation | read-only | mandatory | The location description of the FRU within the enclosure. The string will be empty if the location could not be determined. |
| 1.3.6.1.4.1.232.22.2.3.1.5.1.7 | ColumncpqRackCommonEnclosureFruAssemblyPartNumber | read-only | mandatory | The assembly part number of the FRU within the enclosure. The string will be empty if the enclosure does not report this information. |
| 1.3.6.1.4.1.232.22.2.3.1.5.1.8 | ColumncpqRackCommonEnclosureFruSparePartNumber | read-only | mandatory | The spare part number of the FRU within the enclosure. The string will be empty if the enclosure does not report this information. |
| 1.3.6.1.4.1.232.22.2.3.1.5.1.9 | ColumncpqRackCommonEnclosureFruAutoRev | read-only | mandatory | The auto revision number of the FRU within the enclosure. The string will be empty if the enclosure does not report this information. |
| 1.3.6.1.4.1.232.22.2.3.1.5.1.10 | ColumncpqRackCommonEnclosureFruSerialNum | read-only | mandatory | The serial number of the FRU within the enclosure. The string will be empty if the enclosure does not report the serial number. |
| 1.3.6.1.4.1.232.22.2.3.1.6 | TablecpqRackCommonEnclosureManagerTable | not-accessible | mandatory | A table of rack enclosure manager information. |
| 1.3.6.1.4.1.232.22.2.3.1.6.1 | RowcpqRackCommonEnclosureManagerEntry | not-accessible | mandatory | A rack enclosure manager description. |
| 1.3.6.1.4.1.232.22.2.3.1.6.1.1 | ColumncpqRackCommonEnclosureManagerRack | read-only | mandatory | A number that uniquely specifies this rack. |
| 1.3.6.1.4.1.232.22.2.3.1.6.1.2 | ColumncpqRackCommonEnclosureManagerChassis | read-only | mandatory | A number that uniquely specifies this enclosure in the rack. |
| 1.3.6.1.4.1.232.22.2.3.1.6.1.3 | ColumncpqRackCommonEnclosureManagerIndex | read-only | mandatory | A number that uniquely specifies this manager within this enclosure in the rack. |
| 1.3.6.1.4.1.232.22.2.3.1.6.1.4 | ColumncpqRackCommonEnclosureManagerEnclosureName | read-only | mandatory | The name of the enclosure. The string will be empty if the enclosure does not report the name or it could not be determined. |
| 1.3.6.1.4.1.232.22.2.3.1.6.1.5 | ColumncpqRackCommonEnclosureManagerLocation | read-only | mandatory | The location description of the manager within the enclosure. The string will be empty if the location could not be determined. |
| 1.3.6.1.4.1.232.22.2.3.1.6.1.6 | ColumncpqRackCommonEnclosureManagerPartNumber | read-only | mandatory | The part number of the enclosure manager. The string will be empty if the part number could not be determined. |
| 1.3.6.1.4.1.232.22.2.3.1.6.1.7 | ColumncpqRackCommonEnclosureManagerSparePartNumber | read-only | mandatory | The spare part number of the enclosure manager. The string will be empty if the part number could not be determined. |
| 1.3.6.1.4.1.232.22.2.3.1.6.1.8 | ColumncpqRackCommonEnclosureManagerSerialNum | read-only | mandatory | The serial number of the enclosure manager. The string will be empty if the enclosure does not report the serial number or it could not be determined. |
| 1.3.6.1.4.1.232.22.2.3.1.6.1.9 | ColumncpqRackCommonEnclosureManagerRole | read-only | mandatory | This specifies the current role of the manager. |
| 1.3.6.1.4.1.232.22.2.3.1.6.1.10 | ColumncpqRackCommonEnclosureManagerPresent | read-only | mandatory | This specifies if the manager described is present in the system. |
| 1.3.6.1.4.1.232.22.2.3.1.6.1.11 | ColumncpqRackCommonEnclosureManagerRedundant | read-only | mandatory | This specifies if the manager is in a redundant configuration. |
| 1.3.6.1.4.1.232.22.2.3.1.6.1.12 | ColumncpqRackCommonEnclosureManagerCondition | read-only | mandatory | The condition of the manager. This value will be one of the following: other(1) Manager status detection is not supported. ok(2) The manager is operating prope… |
| 1.3.6.1.4.1.232.22.2.3.1.6.1.13 | ColumncpqRackCommonEnclosureManagerEnclosureSerialNum | read-only | mandatory | The serial number of the enclosure containing the manager. The string will be empty if the enclosure does not report the serial number or it could not be deter… |
| 1.3.6.1.4.1.232.22.2.3.1.6.1.14 | ColumncpqRackCommonEnclosureManagerUUID | read-only | mandatory | The universal unique identifier string of the manager. The string will be empty if the enclosure does not report the UUID string. |
| 1.3.6.1.4.1.232.22.2.3.1.6.1.15 | ColumncpqRackCommonEnclosureManagerFWRev | read-only | mandatory | The firmware revision of the enclosure manager. The string will be empty if the enclosure does not report the firmware revision or does not contain firmware. |
| 1.3.6.1.4.1.232.22.2.3.2 | NodecpqRackServerEnclosure | |||
| 1.3.6.1.4.1.232.22.2.3.2.1 | TablecpqRackServerEnclosureTable | not-accessible | mandatory | A table of rack enclosure information for servers. |
| 1.3.6.1.4.1.232.22.2.3.2.1.1 | RowcpqRackServerEnclosureEntry | not-accessible | mandatory | A server enclosure description. |
| 1.3.6.1.4.1.232.22.2.3.2.1.1.1 | ColumncpqRackServerEnclosureRack | read-only | mandatory | A number that uniquely specifies this rack. |
| 1.3.6.1.4.1.232.22.2.3.2.1.1.2 | ColumncpqRackServerEnclosureIndex | read-only | mandatory | A number that uniquely specifies this server enclosure in the rack. |
| 1.3.6.1.4.1.232.22.2.3.2.1.1.3 | ColumncpqRackServerEnclosureName | read-only | mandatory | The name of the server enclosure. The string will be empty if the enclosure does not report the name or it could not be determined. |
| 1.3.6.1.4.1.232.22.2.3.2.1.1.4 | ColumncpqRackServerEnclosureMaxNumBlades | read-only | mandatory | The maximum number of server blades the enclosure can contain. The string will be empty if the enclosure does not report the name or it could not be determined. |
| 1.3.6.1.4.1.232.22.2.3.2.1.1.5 | ColumncpqRackServerEnclosureMaxNumBladesX | read-only | mandatory | The maximum number of server blades in x-direction (from left to right) the enclosure can contain. |
| 1.3.6.1.4.1.232.22.2.3.2.1.1.6 | ColumncpqRackServerEnclosureMaxNumBladesY | read-only | mandatory | The maximum number of server blades in y-direction (from top to bottom) the enclosure can contain. |
| 1.3.6.1.4.1.232.22.2.3.2.1.1.7 | ColumncpqRackServerEnclosureSolutionsId | read-write | optional | The identifier is used to label enclosure as a BladeSystem Matrix enclosure. Octet Values ===== ============================== 1 Solutions platform identifier … |
| 1.3.6.1.4.1.232.22.2.3.2.2 | ScalarcpqRackLastEAEEvent | read-only | optional | Data for the last EAE event. |
| 1.3.6.1.4.1.232.22.2.3.3 | NodecpqRackPowerEnclosure | |||
| 1.3.6.1.4.1.232.22.2.3.3.1 | TablecpqRackPowerEnclosureTable | not-accessible | mandatory | A table of rack power enclosure information. |
| 1.3.6.1.4.1.232.22.2.3.3.1.1 | RowcpqRackPowerEnclosureEntry | not-accessible | mandatory | A rack power enclosure description. |
| 1.3.6.1.4.1.232.22.2.3.3.1.1.1 | ColumncpqRackPowerEnclosureRack | read-only | mandatory | A number that uniquely specifies this rack. |
| 1.3.6.1.4.1.232.22.2.3.3.1.1.2 | ColumncpqRackPowerEnclosureIndex | read-only | mandatory | A number that uniquely specifies this power enclosure in the rack. |
| 1.3.6.1.4.1.232.22.2.3.3.1.1.3 | ColumncpqRackPowerEnclosureName | read-only | mandatory | The name of the power enclosure. The string will be empty if the enclosure does not report the name or it could not be determined. |
| 1.3.6.1.4.1.232.22.2.3.3.1.1.4 | ColumncpqRackPowerEnclosureMgmtBoardSerialNum | read-only | mandatory | The serial number of the enclosure. The string will be empty if the enclosure does not report the serial number. |
| 1.3.6.1.4.1.232.22.2.3.3.1.1.5 | ColumncpqRackPowerEnclosureRedundant | read-only | mandatory | This indicates if the power supply enclosure is in a redundant state. |
| 1.3.6.1.4.1.232.22.2.3.3.1.1.6 | ColumncpqRackPowerEnclosureLoadBalanced | read-only | mandatory | This indicates if the power supply enclosure is in a load balanced state. |
| 1.3.6.1.4.1.232.22.2.3.3.1.1.7 | ColumncpqRackPowerEnclosureInputPwrType | read-only | mandatory | This indicates type of input facility power. |
| 1.3.6.1.4.1.232.22.2.3.3.1.1.8 | ColumncpqRackPowerEnclosurePwrFeedMax | read-only | mandatory | This is the maximum facility power in watts. The maximum facility power being fed to this power enclosure. The value will be -1 if the power enclosure does not… |
| 1.3.6.1.4.1.232.22.2.3.3.1.1.9 | ColumncpqRackPowerEnclosureCondition | read-only | mandatory | This indicates current condition of the power enclosure. other(1) The power enclosure condition could not be determined. ok(2) The power enclosure is operating… |
| 1.3.6.1.4.1.232.22.2.3.3.1.1.10 | ColumncpqRackPowerEnclosureBladeAutopoweron | read-write | optional | This indicates current condition of the power enclosure. other(1) The blade auto power on feature could not be determined. disabled(2) The enclosure will not a… |
| 1.3.6.1.4.1.232.22.2.4 | NodecpqRackServer | |||
| 1.3.6.1.4.1.232.22.2.4.1 | NodecpqRackServerBlade | |||
| 1.3.6.1.4.1.232.22.2.4.1.1 | TablecpqRackServerBladeTable | not-accessible | mandatory | A table of rack server blade information. |
| 1.3.6.1.4.1.232.22.2.4.1.1.1 | RowcpqRackServerBladeEntry | not-accessible | mandatory | A rack server blade description. |
| 1.3.6.1.4.1.232.22.2.4.1.1.1.1 | ColumncpqRackServerBladeRack | read-only | mandatory | A number that uniquely specifies this rack. |
| 1.3.6.1.4.1.232.22.2.4.1.1.1.2 | ColumncpqRackServerBladeChassis | read-only | mandatory | A number that uniquely specifies this enclosure in the rack. |
| 1.3.6.1.4.1.232.22.2.4.1.1.1.3 | ColumncpqRackServerBladeIndex | read-only | mandatory | A number that uniquely specifies this server blade within the enclosure. |
| 1.3.6.1.4.1.232.22.2.4.1.1.1.4 | ColumncpqRackServerBladeName | read-only | mandatory | The name of the server blade. The string will be empty if it could not be determined. |
| 1.3.6.1.4.1.232.22.2.4.1.1.1.5 | ColumncpqRackServerBladeEnclosureName | read-only | mandatory | The name of the enclosure which contains the blade. The string will be empty if the enclosure does not report the name or it could not be determined. |
| 1.3.6.1.4.1.232.22.2.4.1.1.1.6 | ColumncpqRackServerBladePartNumber | read-only | mandatory | The part number of the server blade. The string will be empty if the part number could not be determined. |
| 1.3.6.1.4.1.232.22.2.4.1.1.1.7 | ColumncpqRackServerBladeSparePartNumber | read-only | mandatory | The spare part number of the server blade. The string will be empty if the part number could not be determined. |
| 1.3.6.1.4.1.232.22.2.4.1.1.1.8 | ColumncpqRackServerBladePosition | read-only | mandatory | The position or slot number of the server blade within the server enclosure. This will be -1 if the server enclosure does not report the information or it coul… |
| 1.3.6.1.4.1.232.22.2.4.1.1.1.9 | ColumncpqRackServerBladeHeight | read-only | mandatory | The height dimension of the rack space taken by the server blade expressed in millimeters. This will be -1 if the rack does not report the information or it co… |
| 1.3.6.1.4.1.232.22.2.4.1.1.1.10 | ColumncpqRackServerBladeWidth | read-only | mandatory | The width dimension of the rack space taken by the server blade expressed in millimeters. This will be -1 if the rack does not report the information or it cou… |
| 1.3.6.1.4.1.232.22.2.4.1.1.1.11 | ColumncpqRackServerBladeDepth | read-only | mandatory | The depth dimension of the rack space taken by the server blade expressed in millimeters. This will be -1 if the rack does not report the information or it cou… |
| 1.3.6.1.4.1.232.22.2.4.1.1.1.12 | ColumncpqRackServerBladePresent | read-only | mandatory | This specifies if the server blade described is present in the enclosure. |
| 1.3.6.1.4.1.232.22.2.4.1.1.1.13 | ColumncpqRackServerBladeHasFuses | read-only | mandatory | The server blade contains fuses. This will be true(2) is the server blade contains fuses. The cpqRackCommonEnclosureFuseTable will contain the fuse specific in… |
| 1.3.6.1.4.1.232.22.2.4.1.1.1.14 | ColumncpqRackServerBladeEnclosureSerialNum | read-only | mandatory | The serial number of the enclosure which contains the blade. The string will be empty if the enclosure does not report the serial number or it could not be det… |
| 1.3.6.1.4.1.232.22.2.4.1.1.1.15 | ColumncpqRackServerBladeSlotsUsed | read-only | mandatory | The number of slot positions occupied by this server blade. This is used to indicate a server blade which may obscure an adjacent blade slot. This will be -1 i… |
| 1.3.6.1.4.1.232.22.2.4.1.1.1.16 | ColumncpqRackServerBladeSerialNum | read-only | mandatory | The serial number of the server blade. The string will be empty if the system does not report the serial number function. |
| 1.3.6.1.4.1.232.22.2.4.1.1.1.17 | ColumncpqRackServerBladeProductId | read-only | mandatory | The product id string of the server blade. The string will be empty if the system does not report the product id function. |
| 1.3.6.1.4.1.232.22.2.4.1.1.1.18 | ColumncpqRackServerBladeUid | read-only | mandatory | The server blade unique identifier (UUID). The string will be empty if the blade does not report the UUID or if it could not be determined. |
| 1.3.6.1.4.1.232.22.2.4.1.1.1.19 | ColumncpqRackServerBladeSlotsUsedX | read-only | mandatory | The number of slot positions in x-direction (from left to right) occupied by this server blade. This is used to indicate a server blade which may obscure an ad… |
| 1.3.6.1.4.1.232.22.2.4.1.1.1.20 | ColumncpqRackServerBladeSlotsUsedY | read-only | mandatory | The number of slot positions in y-direction (from top to bottom) occupied by this server blade. This is used to indicate a server blade which may obscure an ad… |
| 1.3.6.1.4.1.232.22.2.4.1.1.1.21 | ColumncpqRackServerBladeStatus | read-only | optional | The health status of the blade. This will be other(1) if the rack does not report the information or if it could not be determined. |
| 1.3.6.1.4.1.232.22.2.4.1.1.1.22 | ColumncpqRackServerBladeFaultMajor | read-only | optional | The major fault code of the blade fault reported by the enclosure manager. This will be -1 if the rack does not report the information or if it could not be de… |
| 1.3.6.1.4.1.232.22.2.4.1.1.1.23 | ColumncpqRackServerBladeFaultMinor | read-only | optional | The minor fault code of the blade fault reported by the enclosure manager. This will be -1 if the rack does not report the information or if it could not be de… |
| 1.3.6.1.4.1.232.22.2.4.1.1.1.24 | ColumncpqRackServerBladeFaultDiagnosticString | read-only | optional | The server blade fault diagnostic string. This will contain a probable cause and potential diagnostic action to be taken to remedy the fault condition. The str… |
| 1.3.6.1.4.1.232.22.2.4.1.1.1.25 | ColumncpqRackServerBladePowered | read-write | optional | The power state of the blade. This will be other(1) if the rack does not report the information or if it could not be determined. |
| 1.3.6.1.4.1.232.22.2.4.1.1.1.26 | ColumncpqRackServerBladeUIDState | read-write | optional | The Unit Identifier LED. This value will be one of the following: other(1) The state of the LED could not be determined. Setting the LED state is not allowed. … |
| 1.3.6.1.4.1.232.22.2.4.1.1.1.27 | ColumncpqRackServerBladeSystemBIOSRevision | read-only | optional | The server blade system bios revision. The string will be empty if the blade does not report the system bios revision or if it could not be determined. |
| 1.3.6.1.4.1.232.22.2.4.1.1.1.28 | ColumncpqRackServerBladeSystemBIOSFlashingStatus | read-only | optional | Blade server system BIOS flashing / flash mode status indication. This will be other(1) if the rack does not report the information or if it could not be deter… |
| 1.3.6.1.4.1.232.22.2.4.1.1.1.29 | ColumncpqRackServerBladeHasManagementDevice | read-only | optional | The blade server contains one or more management devices. This will be true(2) if the blade server contains managers and false (1) if not or if it can't be det… |
| 1.3.6.1.4.1.232.22.2.4.1.1.1.30 | ColumncpqRackServerBladeManagementDeviceFirmwareRevision | read-only | optional | The server blade management device firwmware revision. The string will be empty if the blade does not report the management device firwmware revision or if it … |
| 1.3.6.1.4.1.232.22.2.4.1.1.1.31 | ColumncpqRackServerBladeManagementDeviceFirmwareFlashingStatus | read-only | optional | Blade server management device firwmware flashing / flash mode status indication. This will be other(1) if the rack does not report this information or if it c… |
| 1.3.6.1.4.1.232.22.2.4.1.1.1.32 | ColumncpqRackServerBladeDiagnosticAdaptorPresence | read-only | optional | This specifies if a blade diagnostic adaptor is currently plugged into the system. |
| 1.3.6.1.4.1.232.22.2.4.1.1.1.33 | ColumncpqRackServerBladeASREnabled | read-only | optional | Indicates whether the target blade server has Automatic Service Recovery feature enabled. This will be true(2) if the blade server has this feature eanbled and… |
| 1.3.6.1.4.1.232.22.2.4.1.1.1.34 | ColumncpqRackServerBladeFrontIOBlankingModeStatus | read-only | optional | Indicates whether the target blade server has the front IO ports blanking feature enabled. This will be Active(3) if the blade server has this feature eanbled,… |
| 1.3.6.1.4.1.232.22.2.4.1.1.1.35 | ColumncpqRackServerBladePOSTStatus | read-only | optional | Blade server power-on self test (POST) status. This value will be one of the following: other(1) The state of the blade POST could not be determined. started(2… |
| 1.3.6.1.4.1.232.22.2.4.1.1.1.36 | ColumncpqRackServerBladePXEBootModeStatus | read-only | optional | Indicates whether the target blade server is in PXE boot mode. This will be Active(3) if the blade server has this feature enbled, Inactive (2) if not, or Unkn… |
| 1.3.6.1.4.1.232.22.2.4.1.1.1.37 | ColumncpqRackServerBladePendingBootOrderChange | read-write | optional | Blade server pending boot order setting change state. This value will be one of the following: other(1) - Unknown or cannot be determined none(2) - No Changes … |
| 1.3.6.1.4.1.232.22.2.4.1.1.1.38 | ColumncpqRackServerBladeWattageMax | read-only | optional | Maximum wattage the server has consumed during this power cycle. |
| 1.3.6.1.4.1.232.22.2.4.1.1.1.39 | ColumncpqRackServerBladeWattageAvg | read-only | optional | Average wattage the server is consuming, averaged over a period defined by the product. |
| 1.3.6.1.4.1.232.22.2.4.1.1.1.40 | ColumncpqRackServerBladeWattageMin | read-only | optional | Minimum wattage the server has consumed, computed from a period defined by the product. Value will be 0 if not supported, but other wattage values are supporte… |
| 1.3.6.1.4.1.232.22.2.4.2 | NodecpqRackServerNetworking | |||
| 1.3.6.1.4.1.232.22.2.4.2.1 | TablecpqRackServerNetworkingTable | not-accessible | optional | A table of rack server networking information. |
| 1.3.6.1.4.1.232.22.2.4.2.1.1 | RowcpqRackServerNetworkingEntry | not-accessible | optional | A rack server networking description. |
| 1.3.6.1.4.1.232.22.2.4.2.1.1.1 | ColumncpqRackServerNetworkingRack | read-only | optional | A number that uniquely specifies this rack. |
| 1.3.6.1.4.1.232.22.2.4.2.1.1.2 | ColumncpqRackServerNetworkingChassis | read-only | mandatory | A number that uniquely specifies this enclosure in the rack. |
| 1.3.6.1.4.1.232.22.2.4.2.1.1.3 | ColumncpqRackServerNetworkingIndex | read-only | optional | A number that uniquely specifies this server within the enclosure. |
| 1.3.6.1.4.1.232.22.2.4.2.1.1.4 | ColumncpqRackServerNetworkingName | read-only | optional | The name of the server. The string will be empty if it could not be determined. |
| 1.3.6.1.4.1.232.22.2.4.2.1.1.5 | ColumncpqRackServerNetworkingEnclosureName | read-only | optional | The name of the enclosure which contains the server. The string will be empty if the enclosure does not report the name or if it could not be determined. |
| 1.3.6.1.4.1.232.22.2.4.2.1.1.6 | ColumncpqRackServerNetworkingEthernetInterfaces | read-only | optional | A number that specifies the amount of Ethernet network interfaces in the server. |
| 1.3.6.1.4.1.232.22.2.4.2.1.1.7 | ColumncpqRackServerNetworkingEthernetMACAddress | read-only | optional | The MAC address for the Ethernet NIC populated in the server. The string will be empty if it could not be determined. |
| 1.3.6.1.4.1.232.22.2.4.3 | NodecpqRackServerTempSensor | |||
| 1.3.6.1.4.1.232.22.2.4.3.1 | TablecpqRackServerTempSensorTable | not-accessible | optional | A table of rack server temperature sensor information. |
| 1.3.6.1.4.1.232.22.2.4.3.1.1 | RowcpqRackServerTempSensorEntry | not-accessible | optional | A rack server temperature sensor description. |
| 1.3.6.1.4.1.232.22.2.4.3.1.1.1 | ColumncpqRackServerTempSensorRack | read-only | optional | A number that uniquely specifies this rack. |
| 1.3.6.1.4.1.232.22.2.4.3.1.1.2 | ColumncpqRackServerTempSensorChassis | read-only | optional | A number that uniquely specifies this enclosure in the rack. |
| 1.3.6.1.4.1.232.22.2.4.3.1.1.3 | ColumncpqRackServerTempSensorIndex | read-only | optional | A number that uniquely specifies this server within the enclosure. |
| 1.3.6.1.4.1.232.22.2.4.3.1.1.4 | ColumncpqRackServerTempSensorName | read-only | optional | The name of the server. The string will be empty if it could not be determined. |
| 1.3.6.1.4.1.232.22.2.4.3.1.1.5 | ColumncpqRackServerTempSensorEnclosureName | read-only | optional | The name of the enclosure which contains the server. The string will be empty if the enclosure does not report the name or if it could not be determined. |
| 1.3.6.1.4.1.232.22.2.4.3.1.1.6 | ColumncpqRackServerTempSensorCount | read-only | optional | A number that specifies the amount of temperature sensors in the server. |
| 1.3.6.1.4.1.232.22.2.4.3.1.1.7 | ColumncpqRackServerTempSensorLocation | read-only | optional | The location description of the temperature sensor within the blade server. The string will be empty if it could not be determined. |
| 1.3.6.1.4.1.232.22.2.4.3.1.1.8 | ColumncpqRackServerTempSensorCurrent | read-only | optional | This is the current temperature sensor reading in degrees celsius. If this value cannot be determined by software, then a value of -1 will be returned. |
| 1.3.6.1.4.1.232.22.2.4.3.1.1.9 | ColumncpqRackServerTempSensorThreshold | read-only | optional | This is the threshold temperature sensor setting in degrees celsius. This is the temperature in which the sensor will be considered to be in a tripped state th… |
| 1.3.6.1.4.1.232.22.2.4.3.1.1.10 | ColumncpqRackServerTempSensorCondition | read-only | optional | The Temperature sensor condition. This value will be one of the following: other(1) Temperature could not be determined. ok(2) The temperature sensor is within… |
| 1.3.6.1.4.1.232.22.2.4.3.1.1.11 | ColumncpqRackServerTempSensorType | read-only | optional | This specifies the type of this instance of temperature sensor. This value will be one of the following: other(1) Temperature threshold type could not be deter… |
| 1.3.6.1.4.1.232.22.2.5 | NodecpqRackPower | |||
| 1.3.6.1.4.1.232.22.2.5.1 | NodecpqRackPowerSupply | |||
| 1.3.6.1.4.1.232.22.2.5.1.1 | TablecpqRackPowerSupplyTable | not-accessible | mandatory | A table of rack power supply information. |
| 1.3.6.1.4.1.232.22.2.5.1.1.1 | RowcpqRackPowerSupplyEntry | not-accessible | mandatory | A rack power supply description. |
| 1.3.6.1.4.1.232.22.2.5.1.1.1.1 | ColumncpqRackPowerSupplyRack | read-only | mandatory | A number that uniquely specifies this rack. |
| 1.3.6.1.4.1.232.22.2.5.1.1.1.2 | ColumncpqRackPowerSupplyChassis | read-only | mandatory | A number that uniquely specifies this power enclosure in the rack. |
| 1.3.6.1.4.1.232.22.2.5.1.1.1.3 | ColumncpqRackPowerSupplyIndex | read-only | mandatory | A number that uniquely specifies this power supply in the enclosure. |
| 1.3.6.1.4.1.232.22.2.5.1.1.1.4 | ColumncpqRackPowerSupplyEnclosureName | read-only | mandatory | The name of the power supply enclosure in which this power supply resides. The string will be empty if the enclosure does not report the name or it could not b… |
| 1.3.6.1.4.1.232.22.2.5.1.1.1.5 | ColumncpqRackPowerSupplySerialNum | read-only | mandatory | The serial number of the power supply. The string will be empty if the power supply does not report the serial number. |
| 1.3.6.1.4.1.232.22.2.5.1.1.1.6 | ColumncpqRackPowerSupplyPartNumber | read-only | mandatory | The part number of the power supply. The string will be empty if the power supply does not report this function. |
| 1.3.6.1.4.1.232.22.2.5.1.1.1.7 | ColumncpqRackPowerSupplySparePartNumber | read-only | mandatory | The spare part number of the power supply. The string will be empty if the power supply does not report this function. |
| 1.3.6.1.4.1.232.22.2.5.1.1.1.8 | ColumncpqRackPowerSupplyFWRev | read-only | mandatory | The firmware revision of the power supply. The string will be empty if the power supply does not report the firmware revision. |
| 1.3.6.1.4.1.232.22.2.5.1.1.1.9 | ColumncpqRackPowerSupplyMaxPwrOutput | read-only | mandatory | The maximum power output of the power supply in watts. The value will be -1 if the power supply does not report the value. |
| 1.3.6.1.4.1.232.22.2.5.1.1.1.10 | ColumncpqRackPowerSupplyCurPwrOutput | read-only | mandatory | The current power output of the power supply in watts. The value will be -1 if the power supply does not report the value. |
| 1.3.6.1.4.1.232.22.2.5.1.1.1.11 | ColumncpqRackPowerSupplyPosition | read-only | mandatory | The position of the power supply within the power enclosure. This will be -1 if the power enclosure does not report the power supply information or it could no… |
| 1.3.6.1.4.1.232.22.2.5.1.1.1.12 | ColumncpqRackPowerSupplyIntakeTemp | read-only | mandatory | The current air temperature at the intake of the power supply in degrees celsius. The value will be -1 if the power supply does not report the value. |
| 1.3.6.1.4.1.232.22.2.5.1.1.1.13 | ColumncpqRackPowerSupplyExhaustTemp | read-only | mandatory | The current air temperature at the exhaust of the power supply in degrees celsius. The value will be -1 if the power supply does not report the value. |
| 1.3.6.1.4.1.232.22.2.5.1.1.1.14 | ColumncpqRackPowerSupplyStatus | read-only | mandatory | The status of the power supply. |
| 1.3.6.1.4.1.232.22.2.5.1.1.1.15 | ColumncpqRackPowerSupplyInputLineStatus | read-only | mandatory | The status of line input power. |
| 1.3.6.1.4.1.232.22.2.5.1.1.1.16 | ColumncpqRackPowerSupplyPresent | read-only | mandatory | This specifies if the power supply described is present in the enclosure. |
| 1.3.6.1.4.1.232.22.2.5.1.1.1.17 | ColumncpqRackPowerSupplyCondition | read-only | mandatory | The condition of the power supply. This value will be one of the following: other(1) The status could not be determined or not present. ok(2) The power supply … |
| 1.3.6.1.4.1.232.22.2.5.1.1.1.18 | ColumncpqRackPowerSupplyEnclosureSerialNum | read-only | mandatory | The serial number of the power supply enclosure in which this power supply resides. The string will be empty if the enclosure does not report the serial number… |
| 1.3.6.1.4.1.232.22.2.5.1.1.1.19 | ColumncpqRackPowerSupplyMeterPort | read-only | mandatory | The corresponding meter used to measure current for this power supply The integer will be -1 if the enclosure does not report the value or it could not be dete… |
| 1.3.6.1.4.1.232.22.2.5.1.1.1.20 | ColumncpqRackPowerSupplyInputCurrent | read-only | mandatory | Input current for the power supply The integer will be -1 if the enclosure does not report the value or it could not be determined. |
| 1.3.6.1.4.1.232.22.2.5.1.1.1.21 | ColumncpqRackPowerSupplyInputPower | read-only | mandatory | Input wattage for the power supply The integer will be -1 if the enclosure does not report the value or it could not be determined. |
| 1.3.6.1.4.1.232.22.2.5.1.1.1.22 | ColumncpqRackPowerSupplyInputVoltage | read-only | mandatory | Input voltage for the power supply The integer will be -1 if the enclosure does not report the value or it could not be determined. |
| 1.3.6.1.4.1.232.22.2.5.1.1.1.23 | ColumncpqRackPowerSupplyOutputCurrent | read-only | mandatory | Output current for the power supply The integer will be -1 if the enclosure does not report the value or it could not be determined. |
| 1.3.6.1.4.1.232.22.2.5.1.1.1.24 | ColumncpqRackPowerSupplyOutputPower | read-only | mandatory | Output wattage for the power supply The integer will be -1 if the enclosure does not report the value or it could not be determined. |
| 1.3.6.1.4.1.232.22.2.5.1.1.1.25 | ColumncpqRackPowerSupplyOutputVoltage | read-only | mandatory | Output voltage for the power supply The integer will be -1 if the enclosure does not report the value or it could not be determined. |
| 1.3.6.1.4.1.232.22.2.5.2 | NodecpqRackPowerMeter | |||
| 1.3.6.1.4.1.232.22.2.5.2.1 | TablecpqRackPowerMeterTable | not-accessible | mandatory | A table of rack power meter information. |
| 1.3.6.1.4.1.232.22.2.5.2.1.1 | RowcpqRackPowerMeterEntry | not-accessible | mandatory | A rack power meter description. |
| 1.3.6.1.4.1.232.22.2.5.2.1.1.1 | ColumncpqRackPowerMeterRack | read-only | mandatory | A number that uniquely specifies this rack. |
| 1.3.6.1.4.1.232.22.2.5.2.1.1.2 | ColumncpqRackPowerMeterChassis | read-only | mandatory | A number that uniquely specifies this power enclosure in the rack. |
| 1.3.6.1.4.1.232.22.2.5.2.1.1.3 | ColumncpqRackPowerMeterIndex | read-only | mandatory | A number that uniquely specifies this power meter in the enclosure. |
| 1.3.6.1.4.1.232.22.2.5.2.1.1.4 | ColumncpqRackPowerMeterType | read-only | mandatory | Class type of power meter - for example 480V The string will be empty if the enclosure does not report the name or it could not be determined. |
| 1.3.6.1.4.1.232.22.2.5.2.1.1.5 | ColumncpqRackPowerMeterPort | read-only | mandatory | Which port on the power enclosure interfaces to this meter The value will be -1 if the power supply does not report this. |
| 1.3.6.1.4.1.232.22.2.5.2.1.1.6 | ColumncpqRackPowerMeterStatus | read-only | mandatory | Operational status value bit field (in hex) from the power meter. Used for diagnostic purposes. Bit definitions are as follows: bit 3 is for SPI communications… |
| 1.3.6.1.4.1.232.22.2.5.2.1.1.7 | ColumncpqRackPowerMeterCurrent | read-only | mandatory | The current measured by the power meter The value will be -1 if the power supply does not report this. |
| 1.3.6.1.4.1.232.22.2.5.2.1.1.8 | ColumncpqRackPowerMeterWattage | read-only | mandatory | The total wattage measured by the power meter The value will be -1 if the power supply does not report this. |
| 1.3.6.1.4.1.232.22.2.6 | NodecpqRackNetwork | |||
| 1.3.6.1.4.1.232.22.2.6.1 | NodecpqRackNetConnector | |||
| 1.3.6.1.4.1.232.22.2.6.1.1 | TablecpqRackNetConnectorTable | not-accessible | mandatory | A table of rack network connector information. |
| 1.3.6.1.4.1.232.22.2.6.1.1.1 | RowcpqRackNetConnectorEntry | not-accessible | mandatory | A rack network connector description. |
| 1.3.6.1.4.1.232.22.2.6.1.1.1.1 | ColumncpqRackNetConnectorRack | read-only | mandatory | A number that uniquely specifies this rack. |
| 1.3.6.1.4.1.232.22.2.6.1.1.1.2 | ColumncpqRackNetConnectorChassis | read-only | mandatory | A number that uniquely specifies this server enclosure in the rack. |
| 1.3.6.1.4.1.232.22.2.6.1.1.1.3 | ColumncpqRackNetConnectorIndex | read-only | mandatory | A number that uniquely specifies this network connector in the rack. |
| 1.3.6.1.4.1.232.22.2.6.1.1.1.4 | ColumncpqRackNetConnectorEnclosureName | read-only | mandatory | The name of the network connector enclosure. The string will be empty if the enclosure does not report the name or it could not be determined. |
| 1.3.6.1.4.1.232.22.2.6.1.1.1.5 | ColumncpqRackNetConnectorName | read-only | mandatory | The name of the network connector. The string will be empty if the network connector does not report the name or it could not be determined. |
| 1.3.6.1.4.1.232.22.2.6.1.1.1.6 | ColumncpqRackNetConnectorModel | read-only | mandatory | The model name of the network connector. The string will be empty if the network connector does not report the model information. |
| 1.3.6.1.4.1.232.22.2.6.1.1.1.7 | ColumncpqRackNetConnectorSerialNum | read-only | mandatory | The serial number of the network connector. The string will be empty if the network connector does not report the serial number. |
| 1.3.6.1.4.1.232.22.2.6.1.1.1.8 | ColumncpqRackNetConnectorPartNumber | read-only | mandatory | The part number of the network connector. The string will be empty if the enclosure does not report this function. |
| 1.3.6.1.4.1.232.22.2.6.1.1.1.9 | ColumncpqRackNetConnectorSparePartNumber | read-only | mandatory | The spare part number of the network connector. The string will be empty if the enclosure does not report this function. |
| 1.3.6.1.4.1.232.22.2.6.1.1.1.10 | ColumncpqRackNetConnectorFWRev | read-only | mandatory | The firmware revision of the network connector. The string will be empty if the network connector does not report the firmware revision. |
| 1.3.6.1.4.1.232.22.2.6.1.1.1.11 | ColumncpqRackNetConnectorType | read-only | mandatory | The type of network connector within the enclosure. |
| 1.3.6.1.4.1.232.22.2.6.1.1.1.12 | ColumncpqRackNetConnectorLocation | read-only | mandatory | The location of the network connector within the enclosure. |
| 1.3.6.1.4.1.232.22.2.6.1.1.1.13 | ColumncpqRackNetConnectorPresent | read-only | mandatory | This specifies if the network connector described is present in the enclosure. |
| 1.3.6.1.4.1.232.22.2.6.1.1.1.14 | ColumncpqRackNetConnectorHasFuses | read-only | mandatory | The network connector contains fuses. This will be true(2) is the network connector contains fuses. The cpqRackCommonEnclosureFuseTable will contain the fuse s… |
| 1.3.6.1.4.1.232.22.2.6.1.1.1.15 | ColumncpqRackNetConnectorEnclosureSerialNum | read-only | mandatory | The serial number of the enclosure containing the network connector. The string will be empty if the enclosure does not report the serial number or it could no… |
| 1.3.6.1.4.1.232.22.2.6.1.1.1.16 | ColumncpqRackNetConnectorTechnologyType | read-only | mandatory | The type of network connector within the enclosure. |
| 1.3.6.1.4.1.232.22.2.6.1.1.1.17 | ColumncpqRackNetConnectorDeviceType | read-only | mandatory | The type of interrconnect in the enclosure. This will be -1 if it is not reported or can not be deteremined. |
| 1.3.6.1.4.1.232.22.2.6.2 | TablecpqRackNetworkAddressesTable | not-accessible | mandatory | A table of rack network addresses. |
| 1.3.6.1.4.1.232.22.2.6.2.1 | RowcpqRackNetworkAddressesEntry | not-accessible | mandatory | Array of ALL the network addresses of the system generating the indication. This may include IPv4 addresses (based on IETF RFC 1208) or IPv6 addresses (based o… |
| 1.3.6.1.4.1.232.22.2.6.2.1.1 | ColumncpqRackNetworkAddresses | read-only | mandatory | A network address of the system generating the indication. |
| 1.3.6.1.4.1.232.22.2.7 | NodecpqRackHW | |||
| 1.3.6.1.4.1.232.22.2.7.1 | ScalarcpqRackHWPartNumber | read-only | optional | Part number for the hardware generating the indication. |
| 1.3.6.1.4.1.232.22.2.7.2 | TablecpqRackHWFirmwareVersionTable | not-accessible | optional | A table of rack firmware versions. |
| 1.3.6.1.4.1.232.22.2.7.2.1 | RowcpqRackHWFirmwareVersionEntry | not-accessible | optional | Array of versions of firmware for the hardware associated with the indication. |
| 1.3.6.1.4.1.232.22.2.7.2.1.1 | ColumncpqRackHWFirmwareVersion | read-only | optional | A version of firmware for the hardware associated with the indication. |
| 1.3.6.1.4.1.232.22.2.7.3 | ScalarcpqRackHWManufacturer | read-only | optional | Manufacturer of the hardware associated with the indication.Device indication hardware manufacturer. |
| 1.3.6.1.4.1.232.22.2.7.4 | TablecpqRackHWSerialNumberTable | not-accessible | optional | A table of rack hardware serial numbers. |
| 1.3.6.1.4.1.232.22.2.7.4.1 | RowcpqRackHWSerialNumberEntry | not-accessible | optional | Array of all the serial numbers of the hardware associated with the indication. |
| 1.3.6.1.4.1.232.22.2.7.4.1.1 | ColumncpqRackHWSerialNumber | read-only | optional | A serial number of the hardware associated with the indication. |
| 1.3.6.1.4.1.232.22.2.7.5 | ScalarcpqRackHWFRUDetails | read-only | optional | This is used to provide miscellaneous FRU specific details Some examples are DIMM size, Processor stepping info etc. |
| 1.3.6.1.4.1.232.22.2.7.6 | ScalarcpqRackHWDevicePermanentNameFormat | read-only | optional | The format of the DevicePermanentName property is interpreted based upon the value of this property. Values are defined as: 1 - unknown. The format is not mean… |
| 1.3.6.1.4.1.232.22.2.7.7 | ScalarcpqRackHWOtherPermanentNameFormat | read-only | optional | A string defining other values for DevicePermanentFormat. It is empty unless DevicePermanentFormat value is other. |
| 1.3.6.1.4.1.232.22.2.8 | NodecpqRackErs | |||
| 1.3.6.1.4.1.232.22.2.8.1 | ScalarcpqRackErsTransactionType | read-only | mandatory | Embedded Remote Support transaction type. The following values are defined: registration(1) Registration operation with Insight Remote Host or Insight Online H… |
| 1.3.6.1.4.1.232.22.2.8.2 | ScalarcpqRackErsConnectionModel | read-only | mandatory | Embedded Remote Support connection model configured on the Onboard Administrator. |
| 1.3.6.1.4.1.232.22.2.8.3 | ScalarcpqRackErsFailureCode | read-only | mandatory | Embedded Remote Support transaction failure code. |
| 1.3.6.1.4.1.232.22.2.8.4 | ScalarcpqRackErsRemoteHost | read-only | mandatory | Remote destination server's hostname and port as configured on the Onboard Administrator. Example: myremotehost.hpe.com:6789 |
| 1.3.6.1.4.1.232.22.2.9 | NodecpqRackEnvironmental | |||
| 1.3.6.1.4.1.232.22.2.9.1 | NodecpqRackThermalController | |||
| 1.3.6.1.4.1.232.22.2.9.1.1 | TablecpqRackThermalControllerTable | not-accessible | mandatory | A table containing the envirnomental controllers in the rack |
| 1.3.6.1.4.1.232.22.2.9.1.1.1 | RowcpqRackThermalControllerEntry | not-accessible | mandatory | Entry containing thermal sensor readings |
| 1.3.6.1.4.1.232.22.2.9.1.1.1.1 | ColumncpqRackThermalControllerIndex | read-only | mandatory | A number that uniquely specifies this thermal controller in the rack. |
| 1.3.6.1.4.1.232.22.2.9.1.1.1.2 | ColumncpqRackThermalControllerLeakDetect1 | read-only | mandatory | TRUE if sensor 1 detected a leak |
| 1.3.6.1.4.1.232.22.2.9.1.1.1.3 | ColumncpqRackThermalControllerLeakDetect2 | read-only | mandatory | TRUE if sensor 2 detected a leak |
| 1.3.6.1.4.1.232.22.2.9.1.1.1.4 | ColumncpqRackThermalControllerLeakDetect3 | read-only | mandatory | TRUE if sensor 3 detected a leak |
| 1.3.6.1.4.1.232.22.2.9.1.1.1.5 | ColumncpqRackThermalControllerLeakDetectFacility | read-only | mandatory | TRUE if overhead sensor detected a leak |
| 1.3.6.1.4.1.232.22.2.9.1.1.1.6 | ColumncpqRackThermalControllerDoorSensorFront | read-only | mandatory | 1 if front door is open |
| 1.3.6.1.4.1.232.22.2.9.1.1.1.7 | ColumncpqRackThermalControllerDoorSensorRear | read-only | mandatory | 1 if rear door is open |
| 1.3.6.1.4.1.232.22.2.9.1.1.1.8 | ColumncpqRackThermalControllerDoorControlFront | read-write | mandatory | 1 to open front door |
| 1.3.6.1.4.1.232.22.2.9.1.1.1.9 | ColumncpqRackThermalControllerDoorControlRear1 | read-write | mandatory | 1 to open rear door |
| 1.3.6.1.4.1.232.22.2.9.1.1.1.10 | ColumncpqRackThermalControllerDoorControlRear2 | read-write | mandatory | 1 to open rear door |
| 1.3.6.1.4.1.232.22.2.9.1.1.1.11 | ColumncpqRackThermalControllerAirTempSensorFront1 | read-only | mandatory | Front air temperature in C |
| 1.3.6.1.4.1.232.22.2.9.1.1.1.12 | ColumncpqRackThermalControllerAirTempSensorFront2 | read-only | mandatory | Front air temperature in C |
| 1.3.6.1.4.1.232.22.2.9.1.1.1.13 | ColumncpqRackThermalControllerAirTempSensorFront3 | read-only | mandatory | Front air temperature in C |
| 1.3.6.1.4.1.232.22.2.9.1.1.1.14 | ColumncpqRackThermalControllerAirTempSensorFront4 | read-only | mandatory | Front air temperature in C |
| 1.3.6.1.4.1.232.22.2.9.1.1.1.15 | ColumncpqRackThermalControllerAirTempSensorRear1 | read-only | mandatory | Rear air temperature in C |
| 1.3.6.1.4.1.232.22.2.9.1.1.1.16 | ColumncpqRackThermalControllerAirTempSensorRear2 | read-only | mandatory | Rear air temperature in C |
| 1.3.6.1.4.1.232.22.2.9.1.1.1.17 | ColumncpqRackThermalControllerAirTempSensorRear3 | read-only | mandatory | Rear air temperature in C |
| 1.3.6.1.4.1.232.22.2.9.1.1.1.18 | ColumncpqRackThermalControllerAirTempSensorRear4 | read-only | mandatory | Rear air temperature in C |
| 1.3.6.1.4.1.232.22.2.9.1.1.1.19 | ColumncpqRackThermalControllerControlValveSupply | read-only | mandatory | Supply valve status |
| 1.3.6.1.4.1.232.22.2.9.1.1.1.20 | ColumncpqRackThermalControllerControlValveReturn | read-only | mandatory | Return valve status |
| 1.3.6.1.4.1.232.22.2.9.1.1.1.21 | ColumncpqRackThermalControllerWaterTempSupply | read-only | mandatory | Water temperature supply in C |
| 1.3.6.1.4.1.232.22.2.9.1.1.1.22 | ColumncpqRackThermalControllerWaterTempReturn | read-only | mandatory | Water temperature return in C |
| 1.3.6.1.4.1.232.22.2.9.1.1.1.23 | ColumncpqRackThermalControllerITFlowSensor | read-only | mandatory | Flow sensor to IT equipment |
| 1.3.6.1.4.1.232.22.2.9.1.1.1.24 | ColumncpqRackThermalControllerCDUFlowSensor | read-only | mandatory | Flow sensor to CDU |
| 1.3.6.1.4.1.232.22.2.9.1.1.1.25 | ColumncpqRackThermalControllerWaterPressureSupply | read-only | mandatory | Supply water pressure |
| 1.3.6.1.4.1.232.22.2.9.1.1.1.26 | ColumncpqRackThermalControllerWaterPressureReturn | read-only | mandatory | Return water pressure |
| 1.3.6.1.4.1.232.22.2.9.1.1.1.27 | ColumncpqRackThermalControllerARPO | read-only | mandatory | Emergency power off status |
| 1.3.6.1.4.1.232.22.2.9.1.1.1.28 | ColumncpqRackThermalControllerChassisRopeSensor1 | read-only | mandatory | Leak detected by rope sensor 1 |
| 1.3.6.1.4.1.232.22.2.9.1.1.1.29 | ColumncpqRackThermalControllerChassisRopeSensor2 | read-only | mandatory | Leak detected by rope sensor 2 |
| 1.3.6.1.4.1.232.22.2.9.1.1.1.30 | ColumncpqRackThermalControllerChassisRopeSensor3 | read-only | mandatory | Leak detected by rope sensor 3 |
| 1.3.6.1.4.1.232.22.2.9.1.1.1.31 | ColumncpqRackThermalControllerChassisRopeSensor4 | read-only | mandatory | Leak detected by rope sensor 4 |
| 1.3.6.1.4.1.232.22.2.9.1.1.1.32 | ColumncpqRackThermalControllerOnBoardTemp | read-only | mandatory | Thermal controller board temperature in C |
| 1.3.6.1.4.1.232.22.2.9.1.1.1.33 | ColumncpqRackThermalControllerOnBoardHumidity | read-only | mandatory | Environmental relative humidity |
| 1.3.6.1.4.1.232.22.2.9.1.1.1.34 | ColumncpqRackThermalControllerBattery | read-only | mandatory | Presence of thermal controller battery |
| 1.3.6.1.4.1.232.22.2.9.1.1.1.35 | ColumncpqRackThermalControllerAPMCommunications | read-only | mandatory | APM Communications Status |
| 1.3.6.1.4.1.232.22.2.9.1.1.1.36 | ColumncpqRackEnvironmentalTrapDescription | read-only | mandatory | Trap Description including threshold information: Sensor = string, Lo threshold = integer, Hi threshold = integer |
| 1.3.6.1.4.1.232.22.2.10 | NodecpqRackCdu | |||
| 1.3.6.1.4.1.232.22.2.10.1 | NodecpqRackCduApolloController | |||
| 1.3.6.1.4.1.232.22.2.10.1.1 | TablecpqRackCduApolloControllerTable | not-accessible | mandatory | A table of rack Cdu controller information. |
| 1.3.6.1.4.1.232.22.2.10.1.1.1 | RowcpqRackCduApolloControllerEntry | not-accessible | mandatory | A rack Cdu controller description. |
| 1.3.6.1.4.1.232.22.2.10.1.1.1.1 | ColumncpqRackCduApolloControllerCduIndex | read-only | mandatory | A number that uniquely specifies this Cdu in the rack. |
| 1.3.6.1.4.1.232.22.2.10.1.1.1.2 | ColumncpqRackCduApolloControllerFwVersion | read-only | mandatory | This Cdu controller FW version. |
| 1.3.6.1.4.1.232.22.2.10.1.1.1.3 | ColumncpqRackCduApolloControllerPlanAddress | read-only | mandatory | This Cdu controller PLAN address. |
| 1.3.6.1.4.1.232.22.2.10.1.1.1.4 | ColumncpqRackCduApolloControllerPlanStatus | read-only | mandatory | This Cdu controller PLAN status. |
| 1.3.6.1.4.1.232.22.2.10.1.1.1.5 | ColumncpqRackCduApolloControllerBmsFacilityWaterValveControl | read-only | mandatory | This Cdu controller BMS facility water valve control. |
| 1.3.6.1.4.1.232.22.2.10.1.1.1.6 | ColumncpqRackCduApolloControllerBmsPumpBypassValveControl | read-only | mandatory | This Cdu controller BMS pump bypass valve control. |
| 1.3.6.1.4.1.232.22.2.10.1.1.1.7 | ColumncpqRackCduApolloControllerBmsPumpVfdControl | read-only | mandatory | This Cdu controller BMS pump VFD control. |
| 1.3.6.1.4.1.232.22.2.10.1.1.1.8 | ColumncpqRackCduApolloControllerBmsHeartbeat | read-only | mandatory | This Cdu controller heartbeat. |
| 1.3.6.1.4.1.232.22.2.10.2 | NodecpqRackCduApolloFacilityWater | |||
| 1.3.6.1.4.1.232.22.2.10.2.1 | TablecpqRackCduApolloFacilityWaterTable | not-accessible | mandatory | A table of rack Cdu controller information. |
| 1.3.6.1.4.1.232.22.2.10.2.1.1 | RowcpqRackCduApolloFacilityWaterEntry | not-accessible | mandatory | A rack Cdu controller description. |
| 1.3.6.1.4.1.232.22.2.10.2.1.1.1 | ColumncpqRackCduApolloFacilityWaterCduIndex | read-only | mandatory | A number that uniquely specifies this Cdu in the rack. |
| 1.3.6.1.4.1.232.22.2.10.2.1.1.2 | ColumncpqRackCduApolloFacilityWaterSupplyTemp | read-only | mandatory | This Cdu facility water inlet temperature. |
| 1.3.6.1.4.1.232.22.2.10.2.1.1.3 | ColumncpqRackCduApolloFacilityWaterSupplyHiTempAlarmSp | read-only | mandatory | This Cdu high facility inlet temperature alarm set point. |
| 1.3.6.1.4.1.232.22.2.10.2.1.1.4 | ColumncpqRackCduApolloFacilityWaterSupplyIsoValveState | read-only | mandatory | This Cdu facility isolation valve 1 status (open/close). Facility supply. |
| 1.3.6.1.4.1.232.22.2.10.2.1.1.5 | ColumncpqRackCduApolloFacilityWaterReturnTemp | read-only | mandatory | This Cdu facility outlet temperature. |
| 1.3.6.1.4.1.232.22.2.10.2.1.1.6 | ColumncpqRackCduApolloFacilityWaterReturnHiTempAlarmSp | read-only | mandatory | This Cdu facility outlet temperature alarm set point. |
| 1.3.6.1.4.1.232.22.2.10.2.1.1.7 | ColumncpqRackCduApolloFacilityWaterReturnIsoValveState | read-only | mandatory | This Cdu facility isolation valve 2 status (open/close). Facility return. |
| 1.3.6.1.4.1.232.22.2.10.2.1.1.8 | ColumncpqRackCduApolloFacilityWaterRegulatingValveOpening | read-only | mandatory | This Cdu water regulation valve output (from Carel controller). |
| 1.3.6.1.4.1.232.22.2.10.2.1.1.9 | ColumncpqRackCduApolloFacilityWaterPressureHexDifferential | read-only | mandatory | This Cdu facility heat exchanger differential pressure. |
| 1.3.6.1.4.1.232.22.2.10.2.1.1.10 | ColumncpqRackCduApolloFacilityWaterLoDifferentialPressureAlarmSp | read-only | mandatory | This Cdu low facility heat exchanger differential pressure alarm set point. |
| 1.3.6.1.4.1.232.22.2.10.2.1.1.11 | ColumncpqRackCduApolloFacilityWaterPressureInlet | read-only | mandatory | This Cdu facility inlet pressure. |
| 1.3.6.1.4.1.232.22.2.10.2.1.1.12 | ColumncpqRackCduApolloFacilityWaterPressureOutlet | read-only | mandatory | This Cdu facility outlet pressure. |
| 1.3.6.1.4.1.232.22.2.10.3 | NodecpqRackCduApolloItWater | |||
| 1.3.6.1.4.1.232.22.2.10.3.1 | TablecpqRackCduApolloItWaterTable | not-accessible | mandatory | A table of rack Cdu controller information. |
| 1.3.6.1.4.1.232.22.2.10.3.1.1 | RowcpqRackCduApolloItWaterEntry | not-accessible | mandatory | A rack Cdu controller description. |
| 1.3.6.1.4.1.232.22.2.10.3.1.1.1 | ColumncpqRackCduApolloItWaterCduIndex | read-only | mandatory | A number that uniquely specifies this Cdu in the rack. |
| 1.3.6.1.4.1.232.22.2.10.3.1.1.2 | ColumncpqRackCduApolloItWaterSupplyTemp | read-only | mandatory | This Cdu IT heat exchanger inlet/supply temperature. |
| 1.3.6.1.4.1.232.22.2.10.3.1.1.3 | ColumncpqRackCduApolloItWaterSupplyHiDischargeTempSp | read-only | mandatory | This Cdu high IT discharge temperature set point. |
| 1.3.6.1.4.1.232.22.2.10.3.1.1.4 | ColumncpqRackCduApolloItWaterSupplyIsoValveState | read-only | mandatory | This Cdu IT isolation valve 1 state (open/close). IT supply. |
| 1.3.6.1.4.1.232.22.2.10.3.1.1.5 | ColumncpqRackCduApolloItWaterReturnTemp | read-only | mandatory | This Cdu IT heat exchanger discharge/return temperature. |
| 1.3.6.1.4.1.232.22.2.10.3.1.1.6 | ColumncpqRackCduApolloItWaterReturnIsoValveState | read-only | mandatory | This Cdu IT isolation valve 2 state (open/close). IT return. |
| 1.3.6.1.4.1.232.22.2.10.3.1.1.7 | ColumncpqRackCduApolloItWaterPumpSpeed | read-only | mandatory | This Cdu IT pump VFD output (from Carel controller). |
| 1.3.6.1.4.1.232.22.2.10.3.1.1.8 | ColumncpqRackCduApolloItWaterPumpPower | read-only | mandatory | This Cdu IT pump power (calculated). |
| 1.3.6.1.4.1.232.22.2.10.3.1.1.9 | ColumncpqRackCduApolloItWaterPumpSupplyTempSp | read-only | mandatory | This Cdu IT pump supply temperature set point. |
| 1.3.6.1.4.1.232.22.2.10.3.1.1.10 | ColumncpqRackCduApolloItWaterVfdControlLocation | read-only | mandatory | This Cdu IT VFD control location |
| 1.3.6.1.4.1.232.22.2.10.3.1.1.11 | ColumncpqRackCduApolloItWaterVfdCurrent | read-only | mandatory | This Cdu IT VFD current. |
| 1.3.6.1.4.1.232.22.2.10.3.1.1.12 | ColumncpqRackCduApolloItWaterVfdDcVoltage | read-only | mandatory | This Cdu IT VFD DC voltage. |
| 1.3.6.1.4.1.232.22.2.10.3.1.1.13 | ColumncpqRackCduApolloItWaterVfdTemperature | read-only | mandatory | This Cdu IT VFD temperature. |
| 1.3.6.1.4.1.232.22.2.10.3.1.1.14 | ColumncpqRackCduApolloItWaterVfdExternalControlSignal | read-only | mandatory | This Cdu IT VFD external control signal. |
| 1.3.6.1.4.1.232.22.2.10.3.1.1.15 | ColumncpqRackCduApolloItWaterVfdFaultWord1 | read-only | mandatory | This Cdu IT VFD fault word1. |
| 1.3.6.1.4.1.232.22.2.10.3.1.1.16 | ColumncpqRackCduApolloItWaterVfdFaultWord2 | read-only | mandatory | This Cdu IT VFD fault word2. |
| 1.3.6.1.4.1.232.22.2.10.3.1.1.17 | ColumncpqRackCduApolloItWaterVfdFaultWord3 | read-only | mandatory | This Cdu IT VFD fault word3. |
| 1.3.6.1.4.1.232.22.2.10.3.1.1.18 | ColumncpqRackCduApolloItWaterVfdFrequency | read-only | mandatory | This Cdu IT VFD frequency. |
| 1.3.6.1.4.1.232.22.2.10.3.1.1.19 | ColumncpqRackCduApolloItWaterVfdKwhCounter | read-only | mandatory | This Cdu IT VFD KWh counter. |
| 1.3.6.1.4.1.232.22.2.10.3.1.1.20 | ColumncpqRackCduApolloItWaterVfdMwhCounter | read-only | mandatory | This Cdu IT VFD MWh counter. |
| 1.3.6.1.4.1.232.22.2.10.3.1.1.21 | ColumncpqRackCduApolloItWaterVfdOutputVoltage | read-only | mandatory | This Cdu IT VFD output voltage. |
| 1.3.6.1.4.1.232.22.2.10.3.1.1.22 | ColumncpqRackCduApolloItWaterVfdPowerReading | read-only | mandatory | This Cdu IT VFD power reading. |
| 1.3.6.1.4.1.232.22.2.10.3.1.1.23 | ColumncpqRackCduApolloItWaterVfdRunTime | read-only | mandatory | This Cdu IT VFD runtime. |
| 1.3.6.1.4.1.232.22.2.10.3.1.1.24 | ColumncpqRackCduApolloItWaterVfdSpeed | read-only | mandatory | This Cdu IT VFD speed. |
| 1.3.6.1.4.1.232.22.2.10.3.1.1.25 | ColumncpqRackCduApolloItWaterVfdTorque | read-only | mandatory | This Cdu IT VFD torque. |
| 1.3.6.1.4.1.232.22.2.10.3.1.1.26 | ColumncpqRackCduApolloItWaterMotorNominalCurrent | read-only | mandatory | This Cdu IT motor nominal current. |
| 1.3.6.1.4.1.232.22.2.10.3.1.1.27 | ColumncpqRackCduApolloItWaterMotorNominalFrequency | read-only | mandatory | This Cdu IT motor nominal frequency. |
| 1.3.6.1.4.1.232.22.2.10.3.1.1.28 | ColumncpqRackCduApolloItWaterMotorNominalPower | read-only | mandatory | This Cdu IT motor nominal power. |
| 1.3.6.1.4.1.232.22.2.10.3.1.1.29 | ColumncpqRackCduApolloItWaterMotorNominalSpeed | read-only | mandatory | This Cdu IT motor nominal speed. |
| 1.3.6.1.4.1.232.22.2.10.3.1.1.30 | ColumncpqRackCduApolloItWaterMotorNominalVoltage | read-only | mandatory | This Cdu IT motor nominal voltage. |
| 1.3.6.1.4.1.232.22.2.10.3.1.1.31 | ColumncpqRackCduApolloItWaterMotorModbusStatusWord | read-only | mandatory | This Cdu IT motor modbus status word. |
| 1.3.6.1.4.1.232.22.2.10.3.1.1.32 | ColumncpqRackCduApolloItWaterPressureHexDiffActual | read-only | mandatory | This Cdu IT heat exchanger differential pressure actual. |
| 1.3.6.1.4.1.232.22.2.10.3.1.1.33 | ColumncpqRackCduApolloItWaterPressureDiffPressureSp | read-only | mandatory | This Cdu IT heat exchanger differential pressure setpoint. |
| 1.3.6.1.4.1.232.22.2.10.3.1.1.34 | ColumncpqRackCduApolloItWaterPressureLoAlarmSp | read-only | mandatory | This Cdu IT pressure low alarm setpoint. |
| 1.3.6.1.4.1.232.22.2.10.3.1.1.35 | ColumncpqRackCduApolloItWaterPressureHiAlarmSp | read-only | mandatory | This Cdu IT pressure high alarm setpoint. |
| 1.3.6.1.4.1.232.22.2.10.3.1.1.36 | ColumncpqRackCduApolloItWaterPressureHexOutlet | read-only | mandatory | This Cdu IT heat exchanger pressure outlet. |
| 1.3.6.1.4.1.232.22.2.10.3.1.1.37 | ColumncpqRackCduApolloItWaterPressurePumpDischarge | read-only | mandatory | This Cdu IT pump discharge. |
| 1.3.6.1.4.1.232.22.2.10.3.1.1.38 | ColumncpqRackCduApolloItWaterReservoirVacuumPumpOn | read-only | mandatory | This Cdu IT rerservoir vacuum pump on. |
| 1.3.6.1.4.1.232.22.2.10.3.1.1.39 | ColumncpqRackCduApolloItWaterReservoirVacuumPressureCutInSp | read-only | mandatory | This Cdu IT reservoir vacuum pressure cut in setpoint. |
| 1.3.6.1.4.1.232.22.2.10.3.1.1.40 | ColumncpqRackCduApolloItWaterReservoirVacuumPressureCutOutSp | read-only | mandatory | This Cdu IT reservoir vacuum pressure cut out setpoint. |
| 1.3.6.1.4.1.232.22.2.10.3.1.1.41 | ColumncpqRackCduApolloItWaterReservoirVacuumLockOutOffset | read-only | mandatory | This Cdu IT reservoir vacuum lock out offset. |
| 1.3.6.1.4.1.232.22.2.10.3.1.1.42 | ColumncpqRackCduApolloItWaterReservoirVacuumLockedOut | read-only | mandatory | This Cdu IT reservoir vacuum locked out. |
| 1.3.6.1.4.1.232.22.2.10.3.1.1.43 | ColumncpqRackCduApolloItWaterReservoirPressure | read-only | mandatory | This Cdu IT reservoir pressure. |
| 1.3.6.1.4.1.232.22.2.10.3.1.1.44 | ColumncpqRackCduApolloItWaterReservoirVolume | read-only | mandatory | This Cdu IT reservoir volume. |
| 1.3.6.1.4.1.232.22.2.10.3.1.1.45 | ColumncpqRackCduApolloItWaterReservoirTankWaterLevel | read-only | mandatory | This Cdu IT reservoir tank water level. |
| 1.3.6.1.4.1.232.22.2.10.3.1.1.46 | ColumncpqRackCduApolloItWaterReservoirWaterFillOn | read-only | mandatory | This Cdu IT reservoir water fill ON. |
| 1.3.6.1.4.1.232.22.2.10.3.1.1.47 | ColumncpqRackCduApolloItWaterReservoirAirInletValveStatusOn | read-only | mandatory | This Cdu IT reservoir air inlet valve status ON. |
| 1.3.6.1.4.1.232.22.2.10.3.1.1.48 | ColumncpqRackCduApolloItWaterReservoirAirInletValveSolenoidCutInSp | read-only | mandatory | This Cdu IT reservoir air inlet valve solenoid cut in setpoint. |
| 1.3.6.1.4.1.232.22.2.10.3.1.1.49 | ColumncpqRackCduApolloItWaterReservoirAirInletValveSolenoidCutOutSp | read-only | mandatory | This Cdu IT reservoir air inlet valve solenoid cut out setpoint. |
| 1.3.6.1.4.1.232.22.2.10.3.1.1.50 | ColumncpqRackCduApolloItWaterReservoirFlow | read-only | mandatory | This Cdu IT reservoir flow. |
| 1.3.6.1.4.1.232.22.2.10.3.1.1.51 | ColumncpqRackCduApolloItWaterReservoirEnergy | read-only | mandatory | This Cdu IT reservoir energy. |
| 1.3.6.1.4.1.232.22.3 | NodecpqRackSysObjID | |||
| 1.3.6.1.4.1.232.22.3.1 | ScalarcpqRackSystemObjectIdentification | read-only | mandatory | The hardware identification string. The string will reported by the rack firmware. |
| 1.3.6.1.4.1.232.22.4 | NodecpqRackEventInfo | |||
| 1.3.6.1.4.1.232.22.4.1 | ScalarcpqRackEventIndicationIdentifier | read-only | mandatory | The Event Indication Identifier. |
| 1.3.6.1.4.1.232.22.4.2 | ScalarcpqRackEventIndicationTime | read-only | optional | The Event Indication Time. |
| 1.3.6.1.4.1.232.22.4.3 | ScalarcpqRackEventDescription | read-only | optional | The Event Description. |
| 1.3.6.1.4.1.232.22.4.4 | ScalarcpqRackEventSummary | read-only | optional | Short description of the reason for the event. |
| 1.3.6.1.4.1.232.22.4.5 | ScalarcpqRackEventCategory | read-only | optional | Category for the event. This category is intended to be used by the consumer to group events. |
| 1.3.6.1.4.1.232.22.4.6 | ScalarcpqRackOtherEventCategory | read-only | optional | A string defining other values for EventCategory. It is empty unless EventCategory value is other(1). |
| 1.3.6.1.4.1.232.22.4.7 | ScalarcpqRackEventSubCategory | read-only | optional | Sub-category for the event. This sub-category is intended to be used by the consumer in conjunction with the EventCategory to provide additional granularity to… |
| 1.3.6.1.4.1.232.22.4.8 | ScalarcpqRackOtherEventSubCategory | read-only | optional | A string defining other values for EventSubCategory. It is empty unless EventSubCategory value is other(1) |
| 1.3.6.1.4.1.232.22.4.9 | ScalarcpqRackEventThreshold | read-only | optional | Identifies the number of indications that need to occur as part of the internal provider throttling configured for this event. |
| 1.3.6.1.4.1.232.22.4.10 | ScalarcpqRackEventTimeWin | read-only | optional | Identifies the time window during which the EventThreshold number of events need to occur as part of the internal provider throttling configured for this event… |
| 1.3.6.1.4.1.232.22.4.11 | ScalarcpqRackEventActualThreshold | read-only | optional | Identifies the number of indications that have occurred to meet the internal provider throttling configured for this event. |
| 1.3.6.1.4.1.232.22.4.12 | ScalarcpqRackEventActualTimeWin | read-only | optional | Identifies the time window during which the ActualEventThreshold number of events have occurred to meet the internal provider throttling configured for this ev… |
| 1.3.6.1.4.1.232.22.4.13 | ScalarcpqRackEventProviderVersion | read-only | optional | The version of the provider generating this indication. |
| 1.3.6.1.4.1.232.22.4.14 | ScalarcpqRackEventAlertingElementFormat | read-only | optional | The format of the AlertingManagedElement property is interpretable based upon the value of this property. Values are defined as: 1 - unknown. The format is unk… |
| 1.3.6.1.4.1.232.22.4.15 | ScalarcpqRackEventOtherAlertingElementFormat | read-only | optional | A string defining other values for AlertingElementFormat. It is empty unless cpqRackEventAlertingElementFormat value is other(1) |
| 1.3.6.1.4.1.232.22.4.16 | ScalarcpqRackEventImpactedDomain | read-only | optional | ImpactedDomain is an enumerated value indicating the domain this event affects. |
| 1.3.6.1.4.1.232.22.4.17 | ScalarcpqRackEventComplexName | read-only | optional | The name of the complex. |
| 1.3.6.1.4.1.232.22.4.18 | ScalarcpqRackEventPartitionId | read-only | optional | The Unique Identifier for the Partition. The format of the partitionId will be of the form nparId:vparId. |
| 1.3.6.1.4.1.232.22.4.19 | TablecpqRackEventTriggeringLogIDTable | not-accessible | optional | A table of rack of Low Level LOG IDs. |
| 1.3.6.1.4.1.232.22.4.19.1 | RowcpqRackEventTriggeringLogIDEntry | not-accessible | optional | The list of Low level LOG ID which were used to generate this event. The format of the value contained in this array is defined using the TriggeringLogIDFormat… |
| 1.3.6.1.4.1.232.22.4.19.1.1 | ColumncpqRackEventTriggeringLogID | read-only | optional | A Low Lvevel LOG ID which were used to generate this event. |
| 1.3.6.1.4.1.232.22.4.20 | ScalarcpqRackEventTriggeringLogIDFormat | read-only | optional | The format of the TriggeringLogID property which interpretable based upon the value of this property. Values are defined as: 1 - unknown. The format is unknown… |
| 1.3.6.1.4.1.232.22.4.21 | ScalarcpqRackEventAlertType | read-only | optional | The event alert type. |
| 1.3.6.1.4.1.232.22.4.22 | ScalarcpqRackEventOtherAlertType | read-only | optional | The event other alert type. It is empty unless cpqRackEventAlertType value is other. |
| 1.3.6.1.4.1.232.22.4.23 | ScalarcpqRackEventProbableCause | read-only | optional | An enumerated value that describes the probable cause of the error. |
| 1.3.6.1.4.1.232.22.4.24 | ScalarcpqRackEventProbableCauseDescription | read-only | optional | A free-form string describing the probable cause of the error. |
| 1.3.6.1.4.1.232.22.4.25 | ScalarcpqRackEventPerceivedSeverity | read-only | optional | An enumerated value that describes the severity of the Indication from the point of view of the notifier. |
| 1.3.6.1.4.1.232.22.4.26 | ScalarcpqRackEventOtherSeverity | read-only | optional | Other perceived severity. It is empty unless cpqRackEventPerceivedSeverity value is other. |
| 1.3.6.1.4.1.232.22.4.27 | ScalarcpqRackEventTrending | read-only | optional | The event trending. |
| 1.3.6.1.4.1.232.22.4.28 | ScalarcpqRackEventRecommendedActions | read-only | optional | A free-form string describing recommended actions to take to resolve the error. |
| 1.3.6.1.4.1.232.22.4.29 | ScalarcpqRackEventID | read-only | optional | An instrumentation or provider specific value that describes the underlying real-world event represented by the indication related to the not-OK status. |
| 1.3.6.1.4.1.232.22.4.30 | ScalarcpqRackEventTime | read-only | optional | The event time. |
| 1.3.6.1.4.1.232.22.4.31 | ScalarcpqRackEventSystemCreationClassName | read-only | optional | The event system creation class name. |
| 1.3.6.1.4.1.232.22.4.32 | ScalarcpqRackEventSystemName | read-only | optional | The event system name. |
| 1.3.6.1.4.1.232.22.4.33 | ScalarcpqRackEventProviderName | read-only | optional | The name of the Provider that generated the indication related to the not-OK status. |
| 1.3.6.1.4.1.232.22001 | NodecpqRackNameChanged | Rack name has changed. This trap signifies that an agent or utility has changed the name of the rack. Each of the server blades in each of the enclosure within… | ||
| 1.3.6.1.4.1.232.22002 | NodecpqRackEnclosureNameChanged | The enclosure name has changed. This trap signifies that an agent or utility has changed the name of an enclosure within the rack. Each of the components withi… | ||
| 1.3.6.1.4.1.232.22003 | NodecpqRackEnclosureRemoved | The enclosure has been removed. This trap signifies that an enclosure has been removed from the rack. User Action: None. | ||
| 1.3.6.1.4.1.232.22004 | NodecpqRackEnclosureInserted | The enclosure has been inserted. This trap signifies that an enclosure has been inserted into the rack. User Action: None. | ||
| 1.3.6.1.4.1.232.22005 | NodecpqRackEnclosureTempFailed | The enclosure temperature status has been set to failed. This trap signifies that a enclosure temperature sensor has been tripped indicating an overheat condit… | ||
| 1.3.6.1.4.1.232.22006 | NodecpqRackEnclosureTempDegraded | The enclosure temperature status has been set to degraded. This trap signifies that an enclosure temperature sensor has been tripped indicating a possible over… | ||
| 1.3.6.1.4.1.232.22007 | NodecpqRackEnclosureTempOk | The enclosure temperature status has been set to ok. This trap signifies that an enclosure temperature sensor has returned to normal. User Action: None. | ||
| 1.3.6.1.4.1.232.22008 | NodecpqRackEnclosureFanFailed | The enclosure fan status has been set to failed. This trap signifies that an enclosure fan has failed and no other fans in the redundant fan group are operatin… | ||
| 1.3.6.1.4.1.232.22009 | NodecpqRackEnclosureFanDegraded | The enclosure fan status has been set to degraded. This trap signifies that an enclosure fan has failed but other fans in the redundant fan group are still ope… | ||
| 1.3.6.1.4.1.232.22010 | NodecpqRackEnclosureFanOk | The enclosure fan status has been set to ok. This trap signifies that an enclosure fan has returned to normal operation. User Action: None. | ||
| 1.3.6.1.4.1.232.22011 | NodecpqRackEnclosureFanRemoved | The enclosure fan has been removed. User Action: None. | ||
| 1.3.6.1.4.1.232.22012 | NodecpqRackEnclosureFanInserted | The enclosure fan has been inserted. User Action: None. | ||
| 1.3.6.1.4.1.232.22013 | NodecpqRackPowerSupplyFailed | The power supply status has been set to failed. This trap signifies that a power supply has failed. User Action: Replace the power supply as soon as possible. | ||
| 1.3.6.1.4.1.232.22014 | NodecpqRackPowerSupplyDegraded | The power supply status has been set to degraded. This trap signifies that a power supply has degraded. User Action: Replace the power supply as soon as possib… | ||
| 1.3.6.1.4.1.232.22015 | NodecpqRackPowerSupplyOk | The power supply status has been set to ok. This trap signifies that a power supply has returned to normal operation. User Action: None. | ||
| 1.3.6.1.4.1.232.22016 | NodecpqRackPowerSupplyRemoved | The power supply has been removed. User Action: None. | ||
| 1.3.6.1.4.1.232.22017 | NodecpqRackPowerSupplyInserted | The power supply has been inserted. User Action: None. | ||
| 1.3.6.1.4.1.232.22018 | NodecpqRackPowerSubsystemNotRedundant | The rack power subsystem is no longer in a redundant state. User Action: Replace any failed power supplies as soon as possible to return the system to a redund… | ||
| 1.3.6.1.4.1.232.22019 | NodecpqRackPowerSubsystemLineVoltageProblem | The rack power supply detected an input line voltage problem. User Action: Check the power input for the power supply or replace any failed power supplies as s… | ||
| 1.3.6.1.4.1.232.22020 | NodecpqRackPowerSubsystemOverloadCondition | The rack power subsystem overload condition. User Action: Replace any failed power supplies as soon as possible to return the system to a redundant state. | ||
| 1.3.6.1.4.1.232.22021 | NodecpqRackPowerShedAutoShutdown | Server shutdown due to power shedding. The server blade was shutdown due to a lack of power. User Action: Check power connections or add power supplies. | ||
| 1.3.6.1.4.1.232.22022 | NodecpqRackServerPowerOnFailedNotRedundant | Server power on prevented to preserve redundancy. There is not enough power to power on the server blade and maintain redundancy for the other blades in the en… | ||
| 1.3.6.1.4.1.232.22023 | NodecpqRackServerPowerOnFailedNotEnoughPower | Inadequate power to power on. There is not enough power to power on the server blade. User Action: Check power connections or add power supplies. | ||
| 1.3.6.1.4.1.232.22024 | NodecpqRackServerPowerOnFailedEnclosureNotFound | Inadequate power to power on. There is not enough power to power on the server blade. The server enclosure micro-controller was not found. User Action: Check s… | ||
| 1.3.6.1.4.1.232.22025 | NodecpqRackServerPowerOnFailedPowerChassisNotFound | Inadequate power to power on. There is not enough power to power on the server blade. The power enclosure micro-controller was not found. User Action: Check po… | ||
| 1.3.6.1.4.1.232.22026 | NodecpqRackServerPowerOnManualOverride | Server power on via manual override. The server blade was powered on by a manual override. User Action: None. | ||
| 1.3.6.1.4.1.232.22027 | NodecpqRackFuseOpen | Fuse open. The fuse has been tripped. User Action: Check enclosure and / or blade power connections and reset the fuse. | ||
| 1.3.6.1.4.1.232.22028 | NodecpqRackServerBladeRemoved | Server blade removed. The server blade has been removed from the enclosure. User Action: None. | ||
| 1.3.6.1.4.1.232.22029 | NodecpqRackServerBladeInserted | Server blade inserted. The server blade has been inserted into the enclosure. User Action: None. | ||
| 1.3.6.1.4.1.232.22030 | NodecpqRackPowerChassisNotLoadBalanced | Power subsystem not load balanced. The power subsystem is out of balance for this power enclosure. User Action: Check the power enclosure and power supplies. R… | ||
| 1.3.6.1.4.1.232.22031 | NodecpqRackPowerChassisDcPowerProblem | Power subsystem DC power problem. There is a power subsystem DC power problem for this power enclosure. User Action: Check the power enclosure and power suppli… | ||
| 1.3.6.1.4.1.232.22032 | NodecpqRackPowerChassisAcFacilityPowerExceeded | Power subsystem AC facility input power exceeded. There is a power subsystem Power subsystem AC facility input power exceeded for this power enclosure. User Ac… | ||
| 1.3.6.1.4.1.232.22033 | NodecpqRackPowerUnknownPowerConsumption | Unknown power consumption. There is an unknown power consumer drawing power. User Action: Check the power enclosure and power supplies. Replace any failed or d… | ||
| 1.3.6.1.4.1.232.22034 | NodecpqRackPowerChassisLoadBalancingWireMissing | Power subsystem load balancing wire missing. The power subsystem load balancing wire missing. User Action: Connect the load balancing wire. | ||
| 1.3.6.1.4.1.232.22035 | NodecpqRackPowerChassisTooManyPowerChassis | Power subsystem has too may power enclosures. The maximum number of power enclosures has been exceeded. User Action: Remove the extra power enclosure. | ||
| 1.3.6.1.4.1.232.22036 | NodecpqRackPowerChassisConfigError | Power subsystem improperly configured. The power subsystem has been improperly configured. User Action: Check the cabling of the power enclosure. | ||
| 1.3.6.1.4.1.232.22037 | NodecpqRackEnclosureManagerDegraded | The Onboard Administrator or other management processor status has been set to degraded. This trap signifies that either the Onboard Administrator(s) or its co… | ||
| 1.3.6.1.4.1.232.22038 | NodecpqRackEnclosureManagerOk | The Onboard Administrator or other management processor's status has been set to ok. This trap signifies that an Onboard Administrator or other management proc… | ||
| 1.3.6.1.4.1.232.22039 | NodecpqRackEnclosureManagerRemoved | The Onboard Administrator has been removed. User Action: None. | ||
| 1.3.6.1.4.1.232.22040 | NodecpqRackEnclosureManagerInserted | The Onboard Administrator or other management processor has been inserted. User Action: None. | ||
| 1.3.6.1.4.1.232.22041 | NodecpqRackManagerPrimaryRole | The Onboard Administrator or other management processor has taken the role of primary. User Action: None. | ||
| 1.3.6.1.4.1.232.22042 | NodecpqRackServerBladeEKeyingFailed | The server blade e-keying has failed. This trap signifies that a server blade e-keying has failed and there is a port mapping problem between a server mezz car… | ||
| 1.3.6.1.4.1.232.22043 | NodecpqRackServerBladeEKeyingOK | The server blade e-keying is ok. This trap signifies that a server blade e-keying has returned to normal operation. User Action: None. | ||
| 1.3.6.1.4.1.232.22044 | NodecpqRackNetConnectorRemoved | Interconnect removed. The interconnect has been removed from the enclosure. User Action: None. | ||
| 1.3.6.1.4.1.232.22045 | NodecpqRackNetConnectorInserted | Interconnect inserted. The interconnect has been inserted into the enclosure. User Action: None. | ||
| 1.3.6.1.4.1.232.22046 | NodecpqRackNetConnectorFailed | The interconnect status has been set to failed. This trap signifies that a interconnect has failed. User Action: Replace the interconnect as soon as possible. | ||
| 1.3.6.1.4.1.232.22047 | NodecpqRackNetConnectorDegraded | The interconnect status has been set to degraded. This trap signifies that a interconnect has degraded. User Action: Refer to the OA and the status diagnostics… | ||
| 1.3.6.1.4.1.232.22048 | NodecpqRackNetConnectorOk | The interconnect status has been set to ok. This trap signifies that a interconnect has returned to normal operation. User Action: None. | ||
| 1.3.6.1.4.1.232.22049 | NodecpqRackServerBladeToLowPower | The server blade requested to low power. User Action: None. | ||
| 1.3.6.1.4.1.232.22050 | NodecpqRackServerBladeRemoved2 | Server blade removed. The server blade has been removed from the enclosure. User Action: None. | ||
| 1.3.6.1.4.1.232.22051 | NodecpqRackServerBladeInserted2 | Server blade inserted. The server blade has been inserted into the enclosure. User Action: None. | ||
| 1.3.6.1.4.1.232.22052 | NodecpqRackServerBladeStatusRepaired | Server blade repaired. The server blade status has changed to OK. User Action: None. | ||
| 1.3.6.1.4.1.232.22053 | NodecpqRackServerBladeStatusDegraded | Server blade health status Degraded. The server blade health status has changed to Degraded. User Action: Check blade server and enclosure SYSLOG. | ||
| 1.3.6.1.4.1.232.22054 | NodecpqRackServerBladeStatusCritical | Server blade health status Critical. The server blade health status has changed to Critical. User Action: Check blade server and enclosure SYSLOG. | ||
| 1.3.6.1.4.1.232.22055 | NodecpqRackServerBladeGrpCapTimeout | The server blade is not responding to the group capper. The server blade is not responding to capping requests from the enclosure group capper User Action: Res… | ||
| 1.3.6.1.4.1.232.22056 | NodecpqRackServerBladeUnexpectedShutdown | Server blade shutdown unexpectadly. An unexpected shutdown event has occurred for this server blade. User Action: Check blade server and enclosure SYSLOG. | ||
| 1.3.6.1.4.1.232.22057 | NodecpqRackServerBladeMangementControllerFirmwareUpdating | Server blade's management controller firmware updating. This server blade's management controller has started updating it's firmware. User Action: None. | ||
| 1.3.6.1.4.1.232.22058 | NodecpqRackServerBladeMangementControllerFirmwareUpdateComplete | Server blade's management controller firmware update has completed. This server blade's management controller has finished updating it's firmware. User Action:… | ||
| 1.3.6.1.4.1.232.22059 | NodecpqRackServerBladeSystemBIOSFirmwareUpdating | Server blade's system BIOS firmware updating. This server blade's system BIOS has started updating. User Action: None. | ||
| 1.3.6.1.4.1.232.22060 | NodecpqRackServerBladeSystemBIOSFirmwareUpdateCompleted | Server blade's system BIOS firmware update complete. This server blade's system BIOS has completed updating. User Action: None. | ||
| 1.3.6.1.4.1.232.22061 | NodecpqRackServerBladeFrontIOBlankingActive | Server blade has disabled front IO ports. Front IO blanking status has changed to active for this server blade. User Action: None. | ||
| 1.3.6.1.4.1.232.22062 | NodecpqRackServerBladeRemoteFrontIOBlankingInactive | Server blade has front IO blanking mode now inactive. Front IO blanking status has changed to inactive for this server blade. User Action: None. | ||
| 1.3.6.1.4.1.232.22063 | NodecpqRackServerBladeDiagnosticAdaptorInserted | Server blade diagnostic adaptor inserted. Blade diagnostic adaptor status has changed to inserted for this server blade. User Action: None. | ||
| 1.3.6.1.4.1.232.22064 | NodecpqRackServerBladeDiagnosticAdaptorRemoved | Server blade diagnostic adaptor removed. Blade diagnostic adaptor status has changed to removed for this server blade. User Action: None. | ||
| 1.3.6.1.4.1.232.22065 | NodecpqRackServerBladeEnteredPXEBootMode | Server blade has entered PXE Boot Mode. Server blade Pre-Boot-eXecution (PXE) Mode started. User Action: None. | ||
| 1.3.6.1.4.1.232.22066 | NodecpqRackServerBladeExitedPXEBootMode | Server blade has exited PXE Boot Mode. Server blade Pre-Boot-eXecution (PXE) Mode exited. User Action: None. | ||
| 1.3.6.1.4.1.232.22067 | NodecpqRackServerBladeWarmReset | Server blade has been warm reset. Server blade has experienced a warm reset. User Action: None. | ||
| 1.3.6.1.4.1.232.22068 | NodecpqRackServerBladePOSTCompleted | Server blade system BIOS POST complete. Server blade has completed system BIOS Power-On-Self-Test (POST). User Action: None. | ||
| 1.3.6.1.4.1.232.22069 | NodecpqRackServerBladePoweredOn | Server blade has powered on. User Action: None. | ||
| 1.3.6.1.4.1.232.22070 | NodecpqRackServerBladePoweredOff | Server blade has powered off. User Action: None. | ||
| 1.3.6.1.4.1.232.22071 | NodecpqRackInformationalEAETrap | EAE Informational trap | ||
| 1.3.6.1.4.1.232.22072 | NodecpqRackMinorEAETrap | EAE Minor trap | ||
| 1.3.6.1.4.1.232.22073 | NodecpqRackMajorEAETrap | EAE Major trap | ||
| 1.3.6.1.4.1.232.22074 | NodecpqRackCriticalEAETrap | EAE Critical trap | ||
| 1.3.6.1.4.1.232.22075 | NodecpqRackPowerMinorEAETrap | FlexFabric Cmdr Power Subsystem Minor trap. User Action: For FlexFabric Cmdr, please refer to product documentation for possible corrective actions. | ||
| 1.3.6.1.4.1.232.22076 | NodecpqRackPowerMajorEAETrap | FlexFabric Cmdr Power Subsystem Major trap. User Action: For FlexFabric Cmdr, please refer to product documentation for possible corrective actions. | ||
| 1.3.6.1.4.1.232.22077 | NodecpqRackPowerCriticalEAETrap | FlexFabric Cmdr Power Subsystem Critical trap. User Action: For FlexFabric Cmdr, please refer to product documentation for possible corrective actions. | ||
| 1.3.6.1.4.1.232.22078 | NodecpqRackServerBladePartitionChange | Server Blade Partition Changed trap. The server blade is part of a conjoined blade and its partition has changed. User Action: None. | ||
| 1.3.6.1.4.1.232.22079 | NodecpqRackInformationalWSMANTrap | WSMAN Informational trap | ||
| 1.3.6.1.4.1.232.22080 | NodecpqRackMinorWSMANTrap | WSMAN Minor trap | ||
| 1.3.6.1.4.1.232.22081 | NodecpqRackMajorWSMANTrap | WSMAN Major trap | ||
| 1.3.6.1.4.1.232.22082 | NodecpqRackCriticalWSMANTrap | WSMAN Critical trap | ||
| 1.3.6.1.4.1.232.22083 | NodecpqRackEnclosureManagerLinkDown | The Onboard Administrator Network Link is Down. The Onboard Administrator firmware has detected the loss of network link. User Action: Check network connection… | ||
| 1.3.6.1.4.1.232.22084 | NodecpqRackEnclosureManagerLinkUp | The Onboard Administrator Network Link is Up. The Onboard Administrator firmware has detected the presence of network link. User Action: None. | ||
| 1.3.6.1.4.1.232.22085 | NodecpqRackErsCommFailure | The Onboard Administrator to Insight Remote Support or Insight Online communication failed. User Action: Please check the connectivity to Insight Remote Suppor… | ||
| 1.3.6.1.4.1.232.22086 | NodecpqRackPowerSubsystemOverloadConditionRepaired | The rack power subsystem overload condition repaired. | ||
| 1.3.6.1.4.1.232.22087 | NodecpqRackPowerSubsystemRedundancyOk | The rack power subsystem is now redundant. This trap signifies that the enclosure power subsystem redundancy is now restored. User Action : None. | ||
| 1.3.6.1.4.1.232.22088 | NodecpqRackNetConnectorTempDegraded | The Interconnect temperature status has been set to degraded. This trap signifies that an interconnect temperature sensor has been tripped indicating a possibl… | ||
| 1.3.6.1.4.1.232.22089 | NodecpqRackNetConnectorTempOk | The interconnect temperature status has been set to ok. This trap signifies that an interconnect temperature sensor has returned to normal. User Action: None. | ||
| 1.3.6.1.4.1.232.22090 | NodecpqRackEnvironmentalLeakDetected | A leak was detected by one or more leak detect sensors in the rack | ||
| 1.3.6.1.4.1.232.22091 | NodecpqRackEnvironmentalDoorState | A door has been opened or closed in the rack | ||
| 1.3.6.1.4.1.232.22092 | NodecpqRackEnvironmentalAirTempSensor | Air temperature sensor warning condition | ||
| 1.3.6.1.4.1.232.22093 | NodecpqRackEnvironmentalControlValveStatus | Water control valve status | ||
| 1.3.6.1.4.1.232.22094 | NodecpqRackEnvironmentalWaterTempThresholdExceeded | Water Temperature Threshold exceeded | ||
| 1.3.6.1.4.1.232.22095 | NodecpqRackEnvironmentalFlowSensorStatus | Flow sensor status | ||
| 1.3.6.1.4.1.232.22096 | NodecpqRackEnvironmentalWaterPressureThresholdExceeded | Water pressure threshold exceeded | ||
| 1.3.6.1.4.1.232.22097 | NodecpqRackEnvironmentalAutomaticRapidPowerOff | An Automatic Rapid Power Off (ARPO) event occured | ||
| 1.3.6.1.4.1.232.22098 | NodecpqRackEnvironmentalRopeLeakDetectorEvent | Rope leak detector event | ||
| 1.3.6.1.4.1.232.22099 | NodecpqRackEnvironmentalTemperatureThresholdExceeded | Environmental Controller on board temperature sensor exceeded threshold | ||
| 1.3.6.1.4.1.232.22100 | NodecpqRackEnvironmentalHumidityThresholdExceeded | Environmental Controller on board temperature sensor exceeded threshold | ||
| 1.3.6.1.4.1.232.22101 | NodecpqRackEnvironmentalControllerOnBoardBattery | Environmental controller on board Battery is low | ||
| 1.3.6.1.4.1.232.22102 | NodecpqRackEnvironmentalControllerAPMCommunicationFailure | Communcations between Apollo Platform Manager (APM) and the environmental controller failed | ||
| 1.3.6.1.4.1.232.22103 | NodecpqRackEnvironmentalLeakDetectedCritical | A leak was detected by one or more leak detect sensors in the rack | ||
| 1.3.6.1.4.1.232.22104 | NodecpqRackPowerSubsystemReductionModeActivate | All rack power supplies in a bank detected input voltage problem and power reduction mode activated in the enclosure. User Action : None. | ||
| 1.3.6.1.4.1.232.22105 | NodecpqRackPowerSubsystemReductionModeDeactivate | The power reduction mode deactivated in the enclosure. User Action : None. |