MIB Viewer

CPQSCSI-MIB

358 objects
No module-level DESCRIPTION found.
OIDNameAccessStatusDescription
1.3.6.1.4.1.232.5NodecpqScsi
1.3.6.1.4.1.232.5.1NodecpqScsiCntlrStatusChangeSCSI Controller Status Change. The agent has detected a change in the controller status of a SCSI Controller. The variable cpqScsiCntlrStatus indicates the cur…
1.3.6.1.4.1.232.5.1NodecpqScsiMibRev
1.3.6.1.4.1.232.5.1.1ScalarcpqScsiMibRevMajorread-onlymandatoryThe Major Revision level. A change in the major revision level represents a major change in the architecture of the MIB. A change in the major revision level m…
1.3.6.1.4.1.232.5.1.2ScalarcpqScsiMibRevMinorread-onlymandatoryThe Minor Revision level. A change in the minor revision level may represent some minor additional support; no changes to any pre-existing information has occu…
1.3.6.1.4.1.232.5.1.3ScalarcpqScsiMibConditionread-onlymandatoryThe overall condition. This object represents the overall status of the SCSI system represented by this MIB.
1.3.6.1.4.1.232.5.2NodecpqScsiComponent
1.3.6.1.4.1.232.5.2NodecpqScsiLogDrvStatusChangeLogical Drive Status Change. The agent has detected a change in the Logical Drive Status of a SCSI logical drive. The current logical drive status is indicated…
1.3.6.1.4.1.232.5.2.1NodecpqScsiInterface
1.3.6.1.4.1.232.5.2.1.1NodecpqScsiOsNetWare
1.3.6.1.4.1.232.5.2.1.1.1ScalarcpqScsiNw3xDriverNameread-onlydeprecatedSCSI Drive Device Driver Name. This is the name of the NetWare v3.1x SCSI device driver. It can be used for identification purposes.
1.3.6.1.4.1.232.5.2.1.1.2ScalarcpqScsiNw3xDriverVersread-onlydeprecatedSCSI Drive Device Driver Version. This is the version of the NetWare v3.1x SCSI device driver. It can be used for identification purposes.
1.3.6.1.4.1.232.5.2.1.1.3ScalarcpqScsiNw3xDriverPollTyperead-onlydeprecatedSCSI Drive Device Driver Poll Type. The SNMP instrument agent collects information from the device driver in two ways: other(1) The management agent does not r…
1.3.6.1.4.1.232.5.2.1.1.4ScalarcpqScsiNw3xDriverPollTimeread-onlydeprecatedSCSI Drive Device Driver Poll Time. If the nw3xDriverPollType is polled(2) this value shows how frequently, in seconds, the instrument agent requests informati…
1.3.6.1.4.1.232.5.2.1.1.5TablecpqScsiNw3xCntlrInfoTablenot-accessibledeprecatedSCSI Controller Information Table.
1.3.6.1.4.1.232.5.2.1.1.5.1RowcpqScsiNw3xCntlrInfoEntrynot-accessibledeprecatedSCSI Controller Information Table Entry.
1.3.6.1.4.1.232.5.2.1.1.5.1.1ColumncpqScsiNw3xCntlrIndexread-onlydeprecatedSCSI Controller Index. The controller index indicates to which SCSI adapter instance this table entry belongs. The controller index is the physical slot in the…
1.3.6.1.4.1.232.5.2.1.1.5.1.2ColumncpqScsiNw3xBusIndexread-onlydeprecatedSCSI Bus Index. The bus index indicates to which SCSI bus instance on an adapter this table entry belongs. The instances start at one and increment for each SC…
1.3.6.1.4.1.232.5.2.1.1.5.1.3ColumncpqScsiNw3xXptDescread-onlydeprecatedSCSI XPT Description. This is a description of the Transport Layer (XPT) module, CPQSXPT.DSK. The Transport Layer manages requests from the device driver and r…
1.3.6.1.4.1.232.5.2.1.1.5.1.4ColumncpqScsiNw3xXptVersread-onlydeprecatedSCSI XPT Version. This is the version of the Transport Layer (XPT) module, CPQSXPT.DSK. The Transport Layer manages requests from the device driver and routes …
1.3.6.1.4.1.232.5.2.1.1.5.1.5ColumncpqScsiNw3xSimDescread-onlydeprecatedSCSI SIM Description. This is a description of the SCSI Interface Module (SIM). Each type of controller model has a specific SIM designed for it. The SIM accep…
1.3.6.1.4.1.232.5.2.1.1.5.1.6ColumncpqScsiNw3xSimVersread-onlydeprecatedSCSI SIM Version. This is the version of the SCSI Interface Module (SIM). Each type of controller model has a specific SIM designed for it. The SIM accepts req…
1.3.6.1.4.1.232.5.2.1.1.5.1.7ColumncpqScsiNw3xHbaDescread-onlydeprecatedSCSI HBA Description. This is a description of the SCSI Host Bus Adapter (HBA). An HBA represents one instance of a SCSI bus in the SCSI Interface Module (SIM)…
1.3.6.1.4.1.232.5.2.1.1.6TablecpqScsiLogDrvStatTablenot-accessibledeprecatedSCSI Logical Drive Statistics Table.
1.3.6.1.4.1.232.5.2.1.1.6.1RowcpqScsiLogDrvStatEntrynot-accessibledeprecatedSCSI Device Driver Statistics Table Entry.
1.3.6.1.4.1.232.5.2.1.1.6.1.1ColumncpqScsiNw3xStatCntlrIndexread-onlydeprecatedSCSI Controller Index. The controller index indicates to which SCSI adapter instance this table entry belongs. The controller index is the physical slot in the…
1.3.6.1.4.1.232.5.2.1.1.6.1.2ColumncpqScsiNw3xStatBusIndexread-onlydeprecatedSCSI Bus Index. The bus index indicates to which SCSI bus instance on an adapter this table entry belongs. The instances start at one and increment for each SC…
1.3.6.1.4.1.232.5.2.1.1.6.1.3ColumncpqScsiNw3xStatLogDrvIndexread-onlydeprecatedSCSI Logical Drive Index. The logical drive index indicates to which logical drive instance on a SCSI bus this table entry belongs. The logical drive index sta…
1.3.6.1.4.1.232.5.2.1.1.6.1.4ColumncpqScsiNw3xTotalReadsread-onlydeprecatedSCSI Logical Drive Total Reads. This shows the total number of reads performed by the device driver to this logical drive. This number is reset each time the d…
1.3.6.1.4.1.232.5.2.1.1.6.1.5ColumncpqScsiNw3xTotalWritesread-onlydeprecatedSCSI Logical Drive Total Writes. This shows the total number of writes performed by the device driver to this logical drive. This number is reset each time the…
1.3.6.1.4.1.232.5.2.1.1.6.1.6ColumncpqScsiNw3xCorrReadsread-onlydeprecatedSCSI Logical Drive Corrected Reads. This is the total number of read commands sent to the specified logical drive which had to be corrected by fault tolerance.…
1.3.6.1.4.1.232.5.2.1.1.6.1.7ColumncpqScsiNw3xCorrWritesread-onlydeprecatedSCSI Logical Drive Corrected Writes. This is the total number of write commands sent to the specified logical drive which had to be corrected by fault toleranc…
1.3.6.1.4.1.232.5.2.1.1.6.1.8ColumncpqScsiNw3xFatalReadsread-onlydeprecatedSCSI Logical Drive Fatal Reads. This is the total number of read commands sent to the specified logical drive which failed. This number is reset each time the …
1.3.6.1.4.1.232.5.2.1.1.6.1.9ColumncpqScsiNw3xFatalWritesread-onlydeprecatedSCSI Logical Drive Fatal Writes. This is the total number of write commands sent to the specified logical drive which failed. This number is reset each time th…
1.3.6.1.4.1.232.5.2.1.1.7TablecpqScsiVolMapTablenot-accessibledeprecatedSCSI Drive Volume Map Table.
1.3.6.1.4.1.232.5.2.1.1.7.1RowcpqScsiVolMapEntrynot-accessibledeprecatedSCSI Drive Volume Map Table Entry.
1.3.6.1.4.1.232.5.2.1.1.7.1.1ColumncpqScsiNw3xVolCntlrIndexread-onlydeprecatedSCSI Cntlr Index. The controller index indicates to which SCSI adapter instance this table entry belongs. The controller index is the physical slot in the comp…
1.3.6.1.4.1.232.5.2.1.1.7.1.2ColumncpqScsiNw3xVolBusIndexread-onlydeprecatedSCSI Bus Index. The bus index indicates to which SCSI bus instance on an adapter this table entry belongs. The instances start at one and increment for each SC…
1.3.6.1.4.1.232.5.2.1.1.7.1.3ColumncpqScsiNw3xVolLogDrvIndexread-onlydeprecatedSCSI Logical Drive Index. The logical drive index indicates to which logical drive instance on a SCSI bus this table entry belongs. The logical drive index sta…
1.3.6.1.4.1.232.5.2.1.1.7.1.4ColumncpqScsiNw3xVolMapread-onlydeprecatedSCSI Drive Volume Map. This is a data structure containing the volume mappings for this logical drive. There are 8 entries in a NetWare volume mapping. An entr…
1.3.6.1.4.1.232.5.2.1.4NodecpqScsiOsCommon
1.3.6.1.4.1.232.5.2.1.4.1ScalarcpqScsiOsCommonPollFreqread-writemandatoryThe agent`s polling frequency. The frequency, in seconds, at which the agent requests information from the device driver. A frequency of zero indicates that th…
1.3.6.1.4.1.232.5.2.1.4.2TablecpqScsiOsCommonModuleTablenot-accessibledeprecatedA table of software modules that provide an interface to the device this MIB describes.
1.3.6.1.4.1.232.5.2.1.4.2.1RowcpqScsiOsCommonModuleEntrynot-accessibledeprecatedA description of a software modules that provide an interface to the device this MIB describes.
1.3.6.1.4.1.232.5.2.1.4.2.1.1ColumncpqScsiOsCommonModuleIndexread-onlydeprecatedA unique index for this module description.
1.3.6.1.4.1.232.5.2.1.4.2.1.2ColumncpqScsiOsCommonModuleNameread-onlydeprecatedThe module name.
1.3.6.1.4.1.232.5.2.1.4.2.1.3ColumncpqScsiOsCommonModuleVersionread-onlydeprecatedThe module version in XX.YY format. Where XX is the major version number and YY is the minor version number. This field will be a null (size 0) string if the a…
1.3.6.1.4.1.232.5.2.1.4.2.1.4ColumncpqScsiOsCommonModuleDateread-onlydeprecatedThe module date. field octets contents range ===== ====== ======= ===== 1 1-2 year 0..65536 2 3 month 1..12 3 4 day 1..31 4 5 hour 0..23 5 6 minute 0..59 6 7 s…
1.3.6.1.4.1.232.5.2.1.4.2.1.5ColumncpqScsiOsCommonModulePurposeread-onlydeprecatedThe purpose of the module described in this entry.
1.3.6.1.4.1.232.5.2.2NodecpqScsiCntlr
1.3.6.1.4.1.232.5.2.2.1TablecpqScsiCntlrTablenot-accessiblemandatorySCSI Controller Table.
1.3.6.1.4.1.232.5.2.2.1.1RowcpqScsiCntlrEntrynot-accessiblemandatorySCSI Controller Table Entry.
1.3.6.1.4.1.232.5.2.2.1.1.1ColumncpqScsiCntlrIndexread-onlymandatorySCSI Controller Index. The controller index indicates to which SCSI adapter instance this table entry belongs. The controller index is the physical slot in the…
1.3.6.1.4.1.232.5.2.2.1.1.2ColumncpqScsiCntlrBusIndexread-onlymandatorySCSI Bus Index. The bus index indicates to which SCSI bus instance on an adapter this table entry belongs. The instances start at one and increment for each SC…
1.3.6.1.4.1.232.5.2.2.1.1.3ColumncpqScsiCntlrModelread-onlymandatorySCSI Controller Model. The is the controller`s model and can be used for identification purposes. The following values are defined: other(1) The management age…
1.3.6.1.4.1.232.5.2.2.1.1.4ColumncpqScsiCntlrFWVersread-onlymandatorySCSI Controller Firmware Version. This is the version of the firmware on the SCSI controller. If the SCSI controller does not use firmware then this string wil…
1.3.6.1.4.1.232.5.2.2.1.1.5ColumncpqScsiCntlrSWVersread-onlydeprecatedSCSI Controller Software Version. This is the version of any software upgrade which is being used in place of the firmware with the controller. If the SCSI con…
1.3.6.1.4.1.232.5.2.2.1.1.6ColumncpqScsiCntlrSlotread-onlymandatorySCSI Controller Slot. This is the physical slot in which this controller is installed. This information can be used for identification purposes.
1.3.6.1.4.1.232.5.2.2.1.1.7ColumncpqScsiCntlrStatusread-onlymandatorySCSI Controller Status. This is the current status of the controller. The following values are currently defined: other(1) The controller is not operational du…
1.3.6.1.4.1.232.5.2.2.1.1.8ColumncpqScsiCntlrHardResetsread-onlymandatorySCSI Controller Hard Resets. This is the number of times the SCSI Hardware Interface driver detected that the SCSI bus has been reset since the driver was load…
1.3.6.1.4.1.232.5.2.2.1.1.9ColumncpqScsiCntlrSoftResetsread-onlymandatorySCSI Controller Soft Resets. This is the number of times the SCSI Hardware Interface driver has issued a reset command to all devices on a SCSI bus since the d…
1.3.6.1.4.1.232.5.2.2.1.1.10ColumncpqScsiCntlrTimeoutsread-onlymandatorySCSI Controller Time-outs. This is the number of times, since the driver was loaded, that the SCSI Hardware Interface driver issued a SCSI command but did not …
1.3.6.1.4.1.232.5.2.2.1.1.11ColumncpqScsiCntlrBaseIOAddrread-onlymandatorySCSI Controller Base I/O Address. This is the I/O address that the SCSI Hardware Interface driver uses to communicate with the SCSI bus controller. This value …
1.3.6.1.4.1.232.5.2.2.1.1.12ColumncpqScsiCntlrConditionread-onlymandatorySCSI Controller Condition. This is the overall condition of the controller and all of the logical drives and physical drives controlled by it. The following va…
1.3.6.1.4.1.232.5.2.2.1.1.13ColumncpqScsiCntlrSerialNumread-onlymandatorySCSI Controller Serial Number. This is the serial number assigned to the controller. This can be used for identification purposes. This field will be a null (s…
1.3.6.1.4.1.232.5.2.2.1.1.14ColumncpqScsiCntlrBusWidthread-onlymandatorySCSI Controller Data Bus Width. This is the physical width of the controller`s SCSI data bus. other(1) The management agent does not recognize this width. You …
1.3.6.1.4.1.232.5.2.2.1.1.15ColumncpqScsiCntlrModelExtendedread-onlymandatorySCSI Controller Model Name. This is the model name for SCSI controllers not defined by cpqScsiCntlrModel enumerations. This field will be a null (size 0) strin…
1.3.6.1.4.1.232.5.2.2.1.1.16ColumncpqScsiCntlrHwLocationread-onlyoptionalA text description of the hardware location, on complex multi SBB hardware only, for the SCSI controller. A NULL string indicates that the hardware location co…
1.3.6.1.4.1.232.5.2.2.1.1.17ColumncpqScsiCntlrPciLocationread-onlyoptionalA string designating the PCI device location for the controller, following the format DDDD:BB:DD.F, where DDDD is the PCI domain number, BB is the PCI bus numb…
1.3.6.1.4.1.232.5.2.3NodecpqScsiLogDrv
1.3.6.1.4.1.232.5.2.3.1TablecpqScsiLogDrvTablenot-accessiblemandatorySCSI Logical Drive Table.
1.3.6.1.4.1.232.5.2.3.1.1RowcpqScsiLogDrvEntrynot-accessiblemandatorySCSI Logical Drive Entry.
1.3.6.1.4.1.232.5.2.3.1.1.1ColumncpqScsiLogDrvCntlrIndexread-onlymandatorySCSI Logical Drive Controller Index. The controller index indicates to which SCSI adapter instance this table entry belongs.
1.3.6.1.4.1.232.5.2.3.1.1.2ColumncpqScsiLogDrvBusIndexread-onlymandatorySCSI Logical Drive Bus Index. The bus index indicates to which SCSI bus instance on an adapter this table entry belongs.
1.3.6.1.4.1.232.5.2.3.1.1.3ColumncpqScsiLogDrvIndexread-onlymandatorySCSI Logical Drive Index. The logical drive index indicates to which logical drive instance on a SCSI bus this table entry belongs.
1.3.6.1.4.1.232.5.2.3.1.1.4ColumncpqScsiLogDrvFaultTolread-onlymandatorySCSI Logical Drive Fault Tolerance. This shows the fault tolerance mode of the logical drive. The following values are valid for the Logical Drive Fault Tolera…
1.3.6.1.4.1.232.5.2.3.1.1.5ColumncpqScsiLogDrvStatusread-onlymandatorySCSI Logical Drive Status. The logical drive can be in one of the following states: other(1) The management agent does not recognize the status. You may need t…
1.3.6.1.4.1.232.5.2.3.1.1.6ColumncpqScsiLogDrvSizeread-onlymandatorySCSI Logical Drive Size. This is the size of the logical drive in megabytes. This value is calculated using the value 1,048,576 (2^20) as a megabyte. Drive man…
1.3.6.1.4.1.232.5.2.3.1.1.7ColumncpqScsiLogDrvPhyDrvIDsread-onlymandatorySCSI Logical Drive Physical Drive IDs. This lists the physical drive SCSI ID`s which are associated with this logical drive. These are the same IDs which can b…
1.3.6.1.4.1.232.5.2.3.1.1.8ColumncpqScsiLogDrvConditionread-onlymandatorySCSI Logical Drive Condition. This is the overall condition of the logical drive and all of the physical drives which comprise it. The following values are def…
1.3.6.1.4.1.232.5.2.3.1.1.9ColumncpqScsiLogDrvStripeSizeread-onlymandatoryLogical Drive Stripe Size. This is the size of a logical drive stripe in kilobytes.
1.3.6.1.4.1.232.5.2.3.1.1.10ColumncpqScsiLogDrvAvailSparesread-onlymandatorySCSI Logical Drive Available Spares. This indicates if this logical drive has one or more spares designated for it that are not currently in use by another dri…
1.3.6.1.4.1.232.5.2.3.1.1.11ColumncpqScsiLogDrvPercentRebuildread-onlymandatoryLogical Drive Percent Rebuild. After a failed physical drive has been replaced, the physical drive must have its data rebuilt. This value is the percent comple…
1.3.6.1.4.1.232.5.2.3.1.1.12ColumncpqScsiLogDrvOsNameread-onlymandatoryLogical Drive OS Name. The OS name for this array logical drive. This field will be a null (size 0) string if the agent does not support OS name.
1.3.6.1.4.1.232.5.2.4NodecpqScsiPhyDrv
1.3.6.1.4.1.232.5.2.4.1TablecpqScsiPhyDrvTablenot-accessiblemandatorySCSI Physical Drive Table.
1.3.6.1.4.1.232.5.2.4.1.1RowcpqScsiPhyDrvEntrynot-accessiblemandatorySCSI Physical Drive Entry.
1.3.6.1.4.1.232.5.2.4.1.1.1ColumncpqScsiPhyDrvCntlrIndexread-onlymandatorySCSI Physical Drive Controller Index. The controller index indicates to which SCSI adapter instance this table entry belongs. The controller index is the physi…
1.3.6.1.4.1.232.5.2.4.1.1.2ColumncpqScsiPhyDrvBusIndexread-onlymandatorySCSI Physical Drive Bus Index. The bus index indicates to which SCSI bus instance on an adapter this table entry belongs. The instances start at one and increm…
1.3.6.1.4.1.232.5.2.4.1.1.3ColumncpqScsiPhyDrvIndexread-onlymandatorySCSI Physical Drive Index. The physical drive index indicates to which physical drive instance on a SCSI bus this table entry belongs. The physical drive index…
1.3.6.1.4.1.232.5.2.4.1.1.4ColumncpqScsiPhyDrvModelread-onlymandatorySCSI Physical Drive Model. This is a description of the physical drive`s model as returned by the SCSI inquiry command. This can be used for identification pur…
1.3.6.1.4.1.232.5.2.4.1.1.5ColumncpqScsiPhyDrvFWRevread-onlymandatorySCSI Physical Drive Firmware Revision. This is the revision level of the physical drive as returned by the SCSI inquiry command. This can be used for identific…
1.3.6.1.4.1.232.5.2.4.1.1.6ColumncpqScsiPhyDrvVendorread-onlymandatorySCSI Physical Drive Vendor. This is the physical drive vendor`s name as returned by the SCSI inquiry command. This can be used for identification purposes.
1.3.6.1.4.1.232.5.2.4.1.1.7ColumncpqScsiPhyDrvSizeread-onlymandatorySCSI Physical Drive Size in MB. This is the size of the physical drive in megabytes. This value is calculated using the value 1,048,576 (2^20) as a megabyte. D…
1.3.6.1.4.1.232.5.2.4.1.1.8ColumncpqScsiPhyDrvScsiIDread-onlymandatorySCSI Physical Drive SCSI ID. This is the SCSI ID used by the physical drive. SCSI ID`s identify a physical drive on a bus so the controller can communicate wit…
1.3.6.1.4.1.232.5.2.4.1.1.9ColumncpqScsiPhyDrvStatusread-onlymandatorySCSI Physical Drive Status. The physical drive can be in one of the following states: other(1) The drive is in a state other than one of those listed below. ok…
1.3.6.1.4.1.232.5.2.4.1.1.10ColumncpqScsiPhyDrvServiceHoursread-onlymandatorySCSI Physical Drive Service Time in hours. This shows the total number of hours that a physical drive has been operating under the device driver. You can use t…
1.3.6.1.4.1.232.5.2.4.1.1.11ColumncpqScsiPhyDrvHighReadSectorsread-onlymandatorySCSI Physical Drive Sectors Read (high). The phyDrvHighReadSectors and the phyDrvlowReadSectors together show the total number of sectors read from the physica…
1.3.6.1.4.1.232.5.2.4.1.1.12ColumncpqScsiPhyDrvLowReadSectorsread-onlymandatorySCSI Physical Drive Sectors Read (low). The phyDrvHighReadSectors and the phyDrvlowReadSectors together show the total number of sectors read from the physical…
1.3.6.1.4.1.232.5.2.4.1.1.13ColumncpqScsiPhyDrvHighWriteSectorsread-onlymandatorySCSI Physical Drive Sectors Written (high). The phyDrvHighWriteSectors and the phyDrvlowWriteSectors together show the total number of sectors written to the p…
1.3.6.1.4.1.232.5.2.4.1.1.14ColumncpqScsiPhyDrvLowWriteSectorsread-onlymandatorySCSI Physical Drive Sectors Written (low). The phyDrvHighWriteSectors and the phyDrvlowWriteSectors together show the total number of sectors written to the ph…
1.3.6.1.4.1.232.5.2.4.1.1.15ColumncpqScsiPhyDrvHardReadErrsread-onlymandatorySCSI Physical Drive Hard Read Errors. This is the number of read errors that have occurred on a drive that could not be recovered by a physical drive`s Error C…
1.3.6.1.4.1.232.5.2.4.1.1.16ColumncpqScsiPhyDrvHardWriteErrsread-onlymandatorySCSI Physical Drive Hard Write Errors. This is the number of write errors that have occurred on a drive that could not be recovered by retries or any other rec…
1.3.6.1.4.1.232.5.2.4.1.1.17ColumncpqScsiPhyDrvEccCorrReadsread-onlymandatorySCSI Physical Drive ECC Corrected Read Errors (high). This is the number of read requests that the drive had to use an Error Correction Code (ECC) algorithm on…
1.3.6.1.4.1.232.5.2.4.1.1.18ColumncpqScsiPhyDrvRecvReadErrsread-onlymandatorySCSI Physical Drive Recovered Read Errors. This is the number of read requests that the drive had to use retries or other recovery mechanisms on to recover dat…
1.3.6.1.4.1.232.5.2.4.1.1.19ColumncpqScsiPhyDrvRecvWriteErrsread-onlymandatorySCSI Physical Drive Recovered Write Errors. This is the number of write requests that the drive had to use retries or other recovery mechanisms on to recover d…
1.3.6.1.4.1.232.5.2.4.1.1.20ColumncpqScsiPhyDrvSeekErrsread-onlymandatorySCSI Physical Drive Seek Errors. This is the number of times a drive head seek failed during the service time (phyDrvServiceHours). Seek errors will occasional…
1.3.6.1.4.1.232.5.2.4.1.1.21ColumncpqScsiPhyDrvSpinupTimeread-onlymandatorySCSI Physical Drive Spin up Time (tenths of seconds). This is the time it takes for a physical drive to spin up to full speed. Disks require time to gain momen…
1.3.6.1.4.1.232.5.2.4.1.1.22ColumncpqScsiPhyDrvUsedReallocsread-onlymandatorySCSI Physical Drive Used Reallocation Sectors. This shows the number of sectors of the reallocation area that have been used by the physical drive over the lif…
1.3.6.1.4.1.232.5.2.4.1.1.23ColumncpqScsiPhyDrvTimeoutsread-onlymandatorySCSI Physical Drive Time-out Errors. This is the number of times the drive failed to complete a request within a specified amount of time during the service ti…
1.3.6.1.4.1.232.5.2.4.1.1.24ColumncpqScsiPhyDrvPostErrsread-onlymandatorySCSI Physical Drive Power On Self Test (POST) Errors. This is the number of times that a drive failed its self test during the service time (phyDrvServiceHours…
1.3.6.1.4.1.232.5.2.4.1.1.25ColumncpqScsiPhyDrvPostErrCoderead-onlymandatorySCSI Physical Drive Last POST Error Code. This is the result of the last SCSI command which caused a self test to fail. The value is split into three fields. T…
1.3.6.1.4.1.232.5.2.4.1.1.26ColumncpqScsiPhyDrvConditionread-onlymandatorySCSI Physical Drive Condition. This is the overall condition of the physical drive. The following values are defined: other(1) The agent does not recognize the…
1.3.6.1.4.1.232.5.2.4.1.1.27ColumncpqScsiPhyDrvFuncTest1read-onlymandatorySCSI Physical Drive Functional Test 1. This is a percentage value that represents the operating efficiency of a drive. The functional test issues a series of S…
1.3.6.1.4.1.232.5.2.4.1.1.28ColumncpqScsiPhyDrvFuncTest2read-onlymandatorySCSI Physical Drive Functional Test 2. This is a percentage value that represents the operating efficiency of a drive. The functional test issues a series of S…
1.3.6.1.4.1.232.5.2.4.1.1.29ColumncpqScsiPhyDrvStatsPreservedread-onlymandatorySCSI Physical Drive Statistics Preservation Method. This value indicates how all of the objects in this table are saved over a power cycle. If the objects are …
1.3.6.1.4.1.232.5.2.4.1.1.30ColumncpqScsiPhyDrvSerialNumread-onlymandatorySCSI Physical Drive Serial Number. This is the serial number assigned to the physical drive. This value is based upon the serial number as returned by the SCSI…
1.3.6.1.4.1.232.5.2.4.1.1.31ColumncpqScsiPhyDrvLocationread-onlydeprecatedSCSI Physical Drive Location. This is the physical location of where the drive is located. The following values are defined: other(1) The drives are not locate…
1.3.6.1.4.1.232.5.2.4.1.1.32ColumncpqScsiPhyDrvParentread-onlymandatorySCSI Physical Drive Parent. This is the logical drive index to which this physical drive belongs.
1.3.6.1.4.1.232.5.2.4.1.1.33ColumncpqScsiPhyDrvSectorSizeread-onlymandatorySCSI Physical Drive Sector Size in Bytes. This allows one to convert counters that are reported in sectors to bytes.
1.3.6.1.4.1.232.5.2.4.1.1.34ColumncpqScsiPhyDrvHotPlugread-onlymandatorySCSI Physical Drive Hot Plug Support Status. The following values are defined: other(1) The agent is unable to determine if this drive supports hot plug replac…
1.3.6.1.4.1.232.5.2.4.1.1.35ColumncpqScsiPhyDrvPlacementread-onlymandatorySCSI Physical Drive Placement. The following values are defined: other(1) The agent is unable to determine if the drive is internal or external to the system c…
1.3.6.1.4.1.232.5.2.4.1.1.36ColumncpqScsiPhyDrvPreFailMonitoringread-onlymandatorySCSI Physical Drive Predictive Failure Monitoring. The following values are defined: other(1) The agent is unable to determine if the drive supports predictive…
1.3.6.1.4.1.232.5.2.4.1.1.37ColumncpqScsiPhyDrvOsNameread-onlymandatoryPhysical Drive OS Name. The OS name for this SCSI physical drive. This field will be a null (size 0) string if the agent does not support OS name.
1.3.6.1.4.1.232.5.2.4.1.1.38ColumncpqScsiPhyDrvRotationalSpeedread-onlymandatorySCSI Physical Drive Rotational Speed. The following values are defined: other(1) The agent is unable to determine the rotational speed for this drive. rpm7200(…
1.3.6.1.4.1.232.5.2.4.1.1.39ColumncpqScsiPhyDrvMemberLogDrvread-onlymandatoryThe Physical Drive is a Member of a Logical Drive. This is an indication of whether the physical drive is a member of a SCSI logical drive. This variable can b…
1.3.6.1.4.1.232.5.2.5NodecpqScsiTarget
1.3.6.1.4.1.232.5.2.5.1TablecpqScsiTargetTablenot-accessiblemandatorySCSI Target Table.
1.3.6.1.4.1.232.5.2.5.1.1RowcpqScsiTargetEntrynot-accessiblemandatorySCSI Target Entry.
1.3.6.1.4.1.232.5.2.5.1.1.1ColumncpqScsiTargetCntlrIndexread-onlymandatorySCSI Target Controller Index. The controller index indicates to which SCSI adapter instance this table entry belongs. The controller index is the physical slot…
1.3.6.1.4.1.232.5.2.5.1.1.2ColumncpqScsiTargetBusIndexread-onlymandatorySCSI Target Bus Index. The bus index indicates to which SCSI bus instance on an adapter card this table entry belongs. The instances start at one and increment…
1.3.6.1.4.1.232.5.2.5.1.1.3ColumncpqScsiTargetScsiIdIndexread-onlymandatorySCSI Target Device Index. The device index indicates to which device instance on a SCSI bus this table entry belongs. The device index is the SCSI ID being use…
1.3.6.1.4.1.232.5.2.5.1.1.4ColumncpqScsiTargetTyperead-onlymandatorySCSI Device Type. This is the type of SCSI device. The following types are defined: other(1) The agent does not recognize this type. You may need to upgrade yo…
1.3.6.1.4.1.232.5.2.5.1.1.5ColumncpqScsiTargetModelread-onlymandatorySCSI Device Model. This is a description of the device`s model as returned by the SCSI inquiry command. This can be used for identification purposes.
1.3.6.1.4.1.232.5.2.5.1.1.6ColumncpqScsiTargetFWRevread-onlymandatorySCSI Device Firmware Revision. This is the revision level of the device as returned by the SCSI inquiry command. This can be used for identification purposes.
1.3.6.1.4.1.232.5.2.5.1.1.7ColumncpqScsiTargetVendorread-onlymandatorySCSI Device Vendor. This is the device vendor`s name as returned by the SCSI inquiry command. This can be used for identification purposes.
1.3.6.1.4.1.232.5.2.5.1.1.8ColumncpqScsiTargetParityErrsread-onlymandatorySCSI Device Bus Parity Errors. This is the number of parity errors seen on the SCSI bus while processing commands for this SCSI ID. This value is maintained si…
1.3.6.1.4.1.232.5.2.5.1.1.9ColumncpqScsiTargetPhaseErrsread-onlymandatorySCSI Device Bus Phase Errors. This is the number of times the SCSI bus entered an invalid operating state while processing commands for the SCSI ID. This value…
1.3.6.1.4.1.232.5.2.5.1.1.10ColumncpqScsiTargetSelectTimeoutsread-onlymandatorySCSI Device Bus Select Time-outs. This is the number of times the controller attempted to start communications with a device by selecting it but the device did…
1.3.6.1.4.1.232.5.2.5.1.1.11ColumncpqScsiTargetMsgRejectsread-onlymandatorySCSI Device Bus Message Rejects. This is the number of times the device rejected a command because it did not support the specified operation since the SCSI Ha…
1.3.6.1.4.1.232.5.2.5.1.1.12ColumncpqScsiTargetNegPeriodread-onlydeprecatedSCSI Device Negotiated Period. This is the amount of time that was negotiated between the controller and the device as a synchronous transfer window. A synchro…
1.3.6.1.4.1.232.5.2.5.1.1.13ColumncpqScsiTargetLocationread-onlymandatorySCSI Device Location. This is the physical location of where the device is located. The following values are defined: other(1) The device is not located in any…
1.3.6.1.4.1.232.5.2.5.1.1.14ColumncpqScsiTargetNegSpeedread-onlymandatorySCSI Device Negotiated Speed. This is the data transfer speed that was negotiated between the controller and the device. This value is reported in bits per sec…
1.3.6.1.4.1.232.5.2.5.1.1.15ColumncpqScsiTargetPhysWidthread-onlymandatorySCSI Device Data Bus Physical Width. This is the physical width of the device`s SCSI data bus. other(1) The management agent does not recognize this width. You…
1.3.6.1.4.1.232.5.2.5.1.1.16ColumncpqScsiTargetNegWidthread-onlymandatorySCSI Device Data Bus Negotiated Width. This is the width of the device`s SCSI data bus that was negotiated between the controller and the device. This value is…
1.3.6.1.4.1.232.5.2.5.1.1.17ColumncpqScsiTargetTypeExtendedread-onlymandatorySCSI Extended Device Type. This is additional information about the type of SCSI device. The following types are defined: other(1) This target does not have an…
1.3.6.1.4.1.232.5.2.5.1.1.18ColumncpqScsiTargetCurrentSpeedread-onlymandatorySCSI Device Current Data Transfer Speed. The following values are defined: other(1) The agent is unable to determine the current negotiated data transfer speed…
1.3.6.1.4.1.232.5.2.6NodecpqScsiCd
1.3.6.1.4.1.232.5.2.6.1TablecpqScsiCdDrvTablenot-accessiblemandatoryScsi CD-ROM Drive Table.
1.3.6.1.4.1.232.5.2.6.1.1RowcpqScsiCdDrvEntrynot-accessiblemandatoryScsi CD-ROM Drive Entry.
1.3.6.1.4.1.232.5.2.6.1.1.1ColumncpqScsiCdDrvCntlrIndexread-onlymandatorySCSI CD-ROM Drive Controller Index. The controller index indicates to which SCSI adapter instance this CD table entry belongs. The controller index is the phys…
1.3.6.1.4.1.232.5.2.6.1.1.2ColumncpqScsiCdDrvBusIndexread-onlymandatorySCSI CD-ROM Drive Bus Index. The bus index indicates to which SCSI bus instance on an adapter this table entry belongs. The instances start at one and incremen…
1.3.6.1.4.1.232.5.2.6.1.1.3ColumncpqScsiCdDrvScsiIdIndexread-onlymandatorySCSI CD-ROM Drive Index. The CD-ROM drive index indicates to which CD-ROM drive instance on a SCSI bus this table entry belongs. The physical drive index is th…
1.3.6.1.4.1.232.5.2.6.1.1.4ColumncpqScsiCdDrvLunIndexread-onlymandatorySCSI CD-ROM Drive Logical Unit Index. The CD-ROM drive logical unit index indicates to which physical drive logical unit on a SCSI ID instance on a SCSI bus th…
1.3.6.1.4.1.232.5.2.6.1.1.5ColumncpqScsiCdDrvModelread-onlymandatorySCSI CD Device Model. This is a description of the device`s model as returned by the SCSI inquiry command. This can be used for identification purposes.
1.3.6.1.4.1.232.5.2.6.1.1.6ColumncpqScsiCdDrvVendorread-onlymandatorySCSI CD Drive Vendor. This is the CD drive vendor`s name as returned by the SCSI inquiry command. This can be used for identification purposes.
1.3.6.1.4.1.232.5.2.6.1.1.7ColumncpqScsiCdDrvFwRevread-onlymandatorySCSI CD-ROM Firmware Revision. This is used to differentiate the firmware versions which have the same CD-ROM drive vendor and model (as specified by cpqScsiCd…
1.3.6.1.4.1.232.5.2.6.2TablecpqCdLibraryTablenot-accessiblemandatoryCD Library Table.
1.3.6.1.4.1.232.5.2.6.2.1RowcpqCdLibraryEntrynot-accessiblemandatoryCD Library Entry.
1.3.6.1.4.1.232.5.2.6.2.1.1ColumncpqCdLibraryCntlrIndexread-onlymandatorySCSI CD Library Controller Index. The controller index indicates to which SCSI adapter instance this table entry belongs. The controller index is the physical …
1.3.6.1.4.1.232.5.2.6.2.1.2ColumncpqCdLibraryBusIndexread-onlymandatorySCSI CD Library Bus Index. The bus index indicates to which SCSI bus instance on an adapter card this table entry belongs. The instances start at one and incre…
1.3.6.1.4.1.232.5.2.6.2.1.3ColumncpqCdLibraryScsiIdIndexread-onlymandatorySCSI CD Library Device Index. The device index indicates to which device instance on a SCSI bus this table entry belongs. The device index is the SCSI ID being…
1.3.6.1.4.1.232.5.2.6.2.1.4ColumncpqCdLibraryLunIndexread-onlymandatorySCSI CD Library Logical Unit Index. The logical unit index indicates to which Lun device instance on a SCSI bus this table entry belongs. The logical unit inde…
1.3.6.1.4.1.232.5.2.6.2.1.5ColumncpqCdLibraryConditionread-onlymandatoryCD Library Condition. This value represents the overall condition of this CD Library. The library can be in one of the following states: other(1) The library i…
1.3.6.1.4.1.232.5.2.6.2.1.6ColumncpqCdLibraryStatusread-onlymandatoryCD Library Status. This value represents the status of this CD Library. The library can be in one of the following states: other(1) The library is in a state o…
1.3.6.1.4.1.232.5.2.6.2.1.7ColumncpqCdLibraryModelread-onlymandatorySCSI CD Library Device Model. This is a description of the device`s model as returned by the SCSI inquiry command. This can be used for identification purposes.
1.3.6.1.4.1.232.5.2.6.2.1.8ColumncpqCdLibraryVendorread-onlymandatorySCSI CD Library Vendor. This is the CD Library drive vendor`s name as returned by the SCSI inquiry command. This can be used for identification purposes.
1.3.6.1.4.1.232.5.2.6.2.1.9ColumncpqCdLibrarySerialNumberread-onlymandatoryCD Library Serial Number. This is the unit serial number for the library. It can be used for identification purposes.
1.3.6.1.4.1.232.5.2.6.2.1.10ColumncpqCdLibraryDriveListread-onlymandatoryCD Library Drive List This is a data structure containing the list of CD drive ids that are present in this library. The format is: BYTE Controller Number BYTE…
1.3.6.1.4.1.232.5.2.6.2.1.11ColumncpqCdLibraryFwRevread-onlymandatorySCSI CD Library Firmware Revision. This is used to differentiate the firmware versions which have the same CD library vendor and model (as specified in cpqCdLi…
1.3.6.1.4.1.232.5.2.6.2.1.12ColumncpqCdLibraryFwSubtyperead-onlymandatorySCSI CD library Firmware Subtype. This is used to differentiate the firmware versions which have the same vendor and model. CD library will contain a value of …
1.3.6.1.4.1.232.5.3NodecpqScsiPhyDrvStatusChangePhysical Drive Status Change. The agent has detected a change in the status of a SCSI physical drive. The current physical drive status is indicated in the cpq…
1.3.6.1.4.1.232.5.3NodecpqScsiTrap
1.3.6.1.4.1.232.5.3.1ScalarcpqScsiTrapPktsread-onlydeprecatedThe total number of trap packets issued by the SCSI enterprise since the instrument agent was loaded.
1.3.6.1.4.1.232.5.3.2ScalarcpqScsiTrapLogMaxSizeread-onlydeprecatedThe maximum number of entries that will currently be kept in the trap log. If the maximum size has been reached and a new trap occurs the oldest trap will be r…
1.3.6.1.4.1.232.5.3.3TablecpqScsiTrapLogTablenot-accessibledeprecatedAn ordered list of trap log entries (conceptually a queue). The trap log entries will be kept in the order in which they were generated with the most recent tr…
1.3.6.1.4.1.232.5.3.3.1RowcpqScsiTrapLogEntrynot-accessibledeprecatedA description of a trap event.
1.3.6.1.4.1.232.5.3.3.1.1ColumncpqScsiTrapLogIndexread-onlydeprecatedThe value of this object uniquely identifies this trapLogEntry at this time. The most recent trap will have an index of 1 and the oldest trap will have an inde…
1.3.6.1.4.1.232.5.3.3.1.2ColumncpqScsiTrapTyperead-onlydeprecatedThe type of the trap event that this entry describes. This number refers to an entry in a list of traps enumerating the possible traps the SCSI agent may issue.
1.3.6.1.4.1.232.5.3.3.1.3ColumncpqScsiTrapTimeread-onlydeprecatedThe time of the trap event that this entry describes. The time is given in year (first octet), month, day of month, hour, minute, second (last octet) order. Ea…
1.3.6.1.4.1.232.5.4NodecpqTapeComponent
1.3.6.1.4.1.232.5.4.1NodecpqTapePhyDrv
1.3.6.1.4.1.232.5.4.1.1TablecpqTapePhyDrvTablenot-accessiblemandatoryTape Physical Drive Table.
1.3.6.1.4.1.232.5.4.1.1.1RowcpqTapePhyDrvEntrynot-accessiblemandatoryTape Physical Drive Entry.
1.3.6.1.4.1.232.5.4.1.1.1.1ColumncpqTapePhyDrvCntlrIndexread-onlymandatoryTape Physical Drive Controller Index. The controller index indicates to which SCSI adapter instance this tape table entry belongs. The controller index is the …
1.3.6.1.4.1.232.5.4.1.1.1.2ColumncpqTapePhyDrvBusIndexread-onlymandatoryTape Physical Drive Bus Index. The bus index indicates to which SCSI bus instance on an adapter this table entry belongs. The instances start at one and increm…
1.3.6.1.4.1.232.5.4.1.1.1.3ColumncpqTapePhyDrvScsiIdIndexread-onlymandatoryTape Physical Drive Index. The physical drive index indicates to which physical drive instance on a SCSI bus this table entry belongs. The physical drive index…
1.3.6.1.4.1.232.5.4.1.1.1.4ColumncpqTapePhyDrvLunIndexread-onlymandatoryTape Physical Drive Logical Unit Index. The physical drive logical unit index indicates to which physical drive logical unit on a SCSI ID instance on a SCSI bu…
1.3.6.1.4.1.232.5.4.1.1.1.5ColumncpqTapePhyDrvTyperead-onlymandatoryTape Device Type. This is the drives model, and can be used for identification purposes. The following values are defined: other(1) The management agent does n…
1.3.6.1.4.1.232.5.4.1.1.1.6ColumncpqTapePhyDrvConditionread-onlymandatoryTape Physical Drive Status. The physical drive can be in one of the following states: other(1) The drive is in a state other than one of those listed below. ok…
1.3.6.1.4.1.232.5.4.1.1.1.7ColumncpqTapePhyDrvMagSizeread-onlymandatoryTape Physical Drive Magazine Size. The number of tape slots available in the magazine cartridge that is currently loaded into the tape drive. For non-autoloade…
1.3.6.1.4.1.232.5.4.1.1.1.8ColumncpqTapePhyDrvSerialNumberread-onlymandatoryTape Physical Drive Serial Number. This is the unit serial number for the tape drive. It can be used for identification purposes.
1.3.6.1.4.1.232.5.4.1.1.1.9ColumncpqTapePhyDrvCleanReqread-onlymandatoryTape Physical Drive Cleaning Required Status. This is an indication of whether the tape drive heads require a cleaning session to occur. If this variable indic…
1.3.6.1.4.1.232.5.4.1.1.1.10ColumncpqTapePhyDrvCleanTapeReplread-onlymandatoryTape Physical Drive Cleaning Tape Replacement Status. This variable is only applicable to autoloader tape drives. This variable indicates whether the cleaning …
1.3.6.1.4.1.232.5.4.1.1.1.11ColumncpqTapePhyDrvFwSubtyperead-onlymandatoryTape Physical Drive Firmware Subtype. This is used to differentiate the firmware versions which have the same tape drive type (as specified by cpqTapePhyDrvTyp…
1.3.6.1.4.1.232.5.4.1.1.1.12ColumncpqTapePhyDrvNameread-onlymandatoryTape Physical Drive Name. This is a combination of the vendor ID and the product ID as returned by the SCSI inquiry command. This can be used for identificatio…
1.3.6.1.4.1.232.5.4.1.1.1.13ColumncpqTapePhyDrvCleanTapeCountread-onlymandatoryTape Physical Drive Cleaning Tape Count. This variable is only applicable to autoloader tape drives. This variable is a count from a tape drive of the number o…
1.3.6.1.4.1.232.5.4.1.1.1.14ColumncpqTapePhyDrvFwRevread-onlymandatoryTape Physical Drive Firmware Revision. This is the revision level of the physical drive as returned by the SCSI inquiry command. This can be used for identific…
1.3.6.1.4.1.232.5.4.1.1.1.15ColumncpqTapePhyDrvStatusread-onlymandatoryTape Physical Drive Status. The tape physical drive can be in one of the following states: other(1) The tape drive is in a state other than one of those listed…
1.3.6.1.4.1.232.5.4.1.1.1.16ColumncpqTapePhyDrvHotPlugread-onlymandatoryTape Physical Drive Hot Plug Support Status. The following values are defined: other(1) The agent is unable to determine if this drive supports hot plug replac…
1.3.6.1.4.1.232.5.4.1.1.1.17ColumncpqTapePhyDrvPlacementread-onlymandatoryTape Physical Drive Placement. The following values are defined: other(1) The agent is unable to determine if the tape drive is internal or external to the sys…
1.3.6.1.4.1.232.5.4.1.1.1.18ColumncpqTapePhyDrvLibraryDriveread-onlymandatoryTape Physical Drive Library Drive. This variable indicates whether or not the tape drive is part of a tape library. It can be in one of the following states: o…
1.3.6.1.4.1.232.5.4.1.1.1.19ColumncpqTapePhyDrvLoaderNameread-onlymandatoryTape Autoloader Name. This is a combination of the vendor ID and the product ID as returned by the SCSI inquiry command. This can be used for identification pu…
1.3.6.1.4.1.232.5.4.1.1.1.20ColumncpqTapePhyDrvLoaderFwRevread-onlymandatoryTape Autoloader Firmware Revision. This is the firmware revision level of the autoloader as returned by the SCSI inquiry command. This can be used for identifi…
1.3.6.1.4.1.232.5.4.1.1.1.21ColumncpqTapePhyDrvLoaderSerialNumread-onlymandatoryTape Autoloader Serial Number. This is the autoloader serial number. It can be used for identification purposes.
1.3.6.1.4.1.232.5.4.2NodecpqTapeCounters
1.3.6.1.4.1.232.5.4.2.1TablecpqTapeCountersTablenot-accessiblemandatoryTape Counters Table.
1.3.6.1.4.1.232.5.4.2.1.1RowcpqTapeCountersEntrynot-accessiblemandatoryTape Counters Entry.
1.3.6.1.4.1.232.5.4.2.1.1.1ColumncpqTapeCountersCntlrIndexread-onlymandatorySCSI Counters Controller Index. The controller index indicates to which SCSI adapter instance this table entry belongs. The controller index is the physical sl…
1.3.6.1.4.1.232.5.4.2.1.1.2ColumncpqTapeCountersBusIndexread-onlymandatorySCSI Counters Bus Index. The bus index indicates to which SCSI bus instance on an adapter card this table entry belongs. The instances start at one and increme…
1.3.6.1.4.1.232.5.4.2.1.1.3ColumncpqTapeCountersScsiIdIndexread-onlymandatorySCSI Counters Device Index. The device index indicates to which device instance on a SCSI bus this table entry belongs. The device index is the SCSI ID being u…
1.3.6.1.4.1.232.5.4.2.1.1.4ColumncpqTapeCountersLunIndexread-onlymandatorySCSI Counters Logical Unit Index. The logical unit index indicates to which Lun device instance on a SCSI bus this table entry belongs. The logical unit index …
1.3.6.1.4.1.232.5.4.2.1.1.5ColumncpqTapeCountersReWritesread-onlymandatoryTape Device Re-write count. This is the number of times blocks had to be re-written to the device. This value is maintained since the Tape Hardware Interface d…
1.3.6.1.4.1.232.5.4.2.1.1.6ColumncpqTapeCountersReReadsread-onlymandatoryTape Device Re-read count. This is the number of times blocks had to be re-read from the device. This value is maintained since the Tape Hardware Interface dri…
1.3.6.1.4.1.232.5.4.2.1.1.7ColumncpqTapeCountersTotalErrorsread-onlymandatoryTape Device Total Errors. This is the total number of read/write errors encountered. This value is maintained since the Tape Hardware Interface driver was load…
1.3.6.1.4.1.232.5.4.2.1.1.8ColumncpqTapeCountersTotalUncorrectableread-onlymandatoryTape Device Total Uncorrectable Errors. This is the total number of read and write errors which could not be corrected. This value is maintained since the Tape…
1.3.6.1.4.1.232.5.4.2.1.1.9ColumncpqTapeCountersTotalBytesread-onlymandatoryTape Device Total Bytes. This is the number total number of bytes read/written to the tape currently installed in the device. This value is reset whenever a ne…
1.3.6.1.4.1.232.5.4.3NodecpqTapeLibrary
1.3.6.1.4.1.232.5.4.3.1TablecpqTapeLibraryTablenot-accessiblemandatoryTape Library Table.
1.3.6.1.4.1.232.5.4.3.1.1RowcpqTapeLibraryEntrynot-accessiblemandatoryTape Library Entry.
1.3.6.1.4.1.232.5.4.3.1.1.1ColumncpqTapeLibraryCntlrIndexread-onlymandatorySCSI Library Controller Index. The controller index indicates to which SCSI adapter instance this table entry belongs. The controller index is the physical slo…
1.3.6.1.4.1.232.5.4.3.1.1.2ColumncpqTapeLibraryBusIndexread-onlymandatorySCSI Library Bus Index. The bus index indicates to which SCSI bus instance on an adapter card this table entry belongs. The instances start at one and incremen…
1.3.6.1.4.1.232.5.4.3.1.1.3ColumncpqTapeLibraryScsiIdIndexread-onlymandatorySCSI Library Device Index. The device index indicates to which device instance on a SCSI bus this table entry belongs. The device index is the SCSI ID being us…
1.3.6.1.4.1.232.5.4.3.1.1.4ColumncpqTapeLibraryLunIndexread-onlymandatorySCSI Library Logical Unit Index. The logical unit index indicates to which Lun device instance on a SCSI bus this table entry belongs. The logical unit index i…
1.3.6.1.4.1.232.5.4.3.1.1.5ColumncpqTapeLibraryConditionread-onlymandatoryTape Library Status. The library can be in one of the following states: other(1) The library is in a state other than one of those listed below. ok(2) Indicate…
1.3.6.1.4.1.232.5.4.3.1.1.6ColumncpqTapeLibraryStatusread-onlymandatoryError code returned by the last library error.
1.3.6.1.4.1.232.5.4.3.1.1.7ColumncpqTapeLibraryDoorStatusread-onlymandatoryStatus of the library door. The door can be in one of the following states: other(1) The door is in a state other than one of those listed below. closed(2) The…
1.3.6.1.4.1.232.5.4.3.1.1.8ColumncpqTapeLibraryStatHoursread-onlymandatoryThe number of hours of operation for the library.
1.3.6.1.4.1.232.5.4.3.1.1.9ColumncpqTapeLibraryStatMovesread-onlymandatoryThe number of tape moves for the library loader arm.
1.3.6.1.4.1.232.5.4.3.1.1.10ColumncpqTapeLibraryNameread-onlymandatoryTape Library Name.
1.3.6.1.4.1.232.5.4.3.1.1.11ColumncpqTapeLibrarySerialNumberread-onlymandatoryTape Library Serial Number. This is the unit serial number for the library. It can be used for identification purposes.
1.3.6.1.4.1.232.5.4.3.1.1.12ColumncpqTapeLibraryDriveListread-onlydeprecatedTape Library Drive List This is a data structure containing the list of tape drive ids that are present in this library. The format is: BYTE Controller Number …
1.3.6.1.4.1.232.5.4.3.1.1.13ColumncpqTapeLibraryStateread-onlymandatoryTape Library Status. The library can be in one of the following states: other(1) The library is in a state other than one of those listed below. ok(2) Indicate…
1.3.6.1.4.1.232.5.4.3.1.1.14ColumncpqTapeLibraryTemperatureread-onlymandatoryTape Library Temperature Status. The library temperature can be in one of the following states: other(1) The library temperature status is unknown. notSupporte…
1.3.6.1.4.1.232.5.4.3.1.1.15ColumncpqTapeLibraryRedundancyread-onlymandatoryTape Library Redundancy Status. Redundancy status denotes the presence of internal redundant components such as fans, power supplies, etc. The library redundan…
1.3.6.1.4.1.232.5.4.3.1.1.16ColumncpqTapeLibraryHotSwapread-onlymandatoryTape Library Hot Swap Status. Hot swap status denotes the presence of hot swappable internal components such as drives, fans, power supplies, etc. The library …
1.3.6.1.4.1.232.5.4.3.1.1.17ColumncpqTapeLibraryFwRevread-onlymandatoryTape Library Firmware Revision. This is the revision level of the tape library firmware as returned by the SCSI inquiry command. This can be used for identific…
1.3.6.1.4.1.232.5.4.3.1.1.18ColumncpqTapeLibraryTapeListread-onlymandatoryTape Library Drive List This is a data structure containing the list of tape drive ids that are present in this library. The format is: ULONG Controller Number…
1.3.6.1.4.1.232.5.5NodecpqSasComponent
1.3.6.1.4.1.232.5.5.1NodecpqSasHba
1.3.6.1.4.1.232.5.5.1.1TablecpqSasHbaTablenot-accessiblemandatorySAS Host Bus Adapter Table.
1.3.6.1.4.1.232.5.5.1.1.1RowcpqSasHbaEntrynot-accessiblemandatorySAS Controller Table Entry.
1.3.6.1.4.1.232.5.5.1.1.1.1ColumncpqSasHbaIndexread-onlymandatorySAS Host Bus Adapter Index. The HBA index indicates to which SAS adapter instance this table entry belongs.
1.3.6.1.4.1.232.5.5.1.1.1.2ColumncpqSasHbaHwLocationread-onlyoptionalSAS Host Bus Adapter Hardware Location. A text description of the hardware location of the HBA. A NULL string indicates that the hardware location could not be…
1.3.6.1.4.1.232.5.5.1.1.1.3ColumncpqSasHbaModelread-onlymandatorySAS Host Bus Adapter Model. This is the HBA model and can be used for identification purposes. The following values are defined: other(1) The management agent …
1.3.6.1.4.1.232.5.5.1.1.1.4ColumncpqSasHbaStatusread-onlymandatorySAS Host Bus Adapter Status. This is the current status of the HBA. The following values are currently defined: other(1) The management agent does not recogniz…
1.3.6.1.4.1.232.5.5.1.1.1.5ColumncpqSasHbaConditionread-onlymandatorySAS Host Bus Adapter Condition. This is the condition of the HBA hardware.
1.3.6.1.4.1.232.5.5.1.1.1.6ColumncpqSasHbaOverallConditionread-onlymandatorySAS Host Bus Adapter Overall Condition. This is the overall condition of the HBA and all of the logical drives and physical drives controlled by it.
1.3.6.1.4.1.232.5.5.1.1.1.7ColumncpqSasHbaSerialNumberread-onlymandatorySAS Host Bus Adapter Serial Number. This is the serial number assigned to the HBA. This can be used for identification purposes. This field will be a null (siz…
1.3.6.1.4.1.232.5.5.1.1.1.8ColumncpqSasHbaFwVersionread-onlymandatorySAS Host Bus Adapter Firmware Version. This is the version of the firmware on the SAS HBA. This field will be a null (size 0) string if the management agent ca…
1.3.6.1.4.1.232.5.5.1.1.1.9ColumncpqSasHbaBiosVersionread-onlymandatorySAS Host Bus Adapter BIOS Version. This is the version of the BIOS on the SAS HBA. This field will be a null (size 0) string if the management agent cannot pro…
1.3.6.1.4.1.232.5.5.1.1.1.10ColumncpqSasHbaPciLocationread-onlyoptionalSAS Host Bus Adapter PCI Location. A string designating the PCI device location for the controller, following the format DDDD:BB:DD.F, where DDDD is the PCI do…
1.3.6.1.4.1.232.5.5.2NodecpqSasPhyDrv
1.3.6.1.4.1.232.5.5.2.1TablecpqSasPhyDrvTablenot-accessiblemandatorySAS Physical Drive Table.
1.3.6.1.4.1.232.5.5.2.1.1RowcpqSasPhyDrvEntrynot-accessiblemandatorySAS Physical Drive Entry.
1.3.6.1.4.1.232.5.5.2.1.1.1ColumncpqSasPhyDrvHbaIndexread-onlymandatorySAS Physical Drive HBA Index. The HBA index indicates to which SAS adapter instance this table entry belongs.
1.3.6.1.4.1.232.5.5.2.1.1.2ColumncpqSasPhyDrvIndexread-onlymandatorySAS Physical Drive Index. The physical drive index indicates to which physical drive instance this table entry belongs.
1.3.6.1.4.1.232.5.5.2.1.1.3ColumncpqSasPhyDrvLocationStringread-onlymandatorySAS Physical Drive Location String. This string describes the location of the drive in relation to the HBA. If the location string cannot be determined, the ag…
1.3.6.1.4.1.232.5.5.2.1.1.4ColumncpqSasPhyDrvModelread-onlymandatorySAS Physical Drive Model. This is a physical drive`s model name. It can be used for identification purposes.
1.3.6.1.4.1.232.5.5.2.1.1.5ColumncpqSasPhyDrvStatusread-onlymandatorySAS Physical Drive Status. The physical drive can be in one of the following states: other(1) The drive is in a state other than one of those listed below. ok(…
1.3.6.1.4.1.232.5.5.2.1.1.6ColumncpqSasPhyDrvConditionread-onlymandatorySAS Physical Drive Condition. This is the overall condition of the physical drive. The following values are defined: other(1) The agent does not recognize the …
1.3.6.1.4.1.232.5.5.2.1.1.7ColumncpqSasPhyDrvFWRevread-onlymandatorySAS Physical Drive Firmware Revision. This is the firmware revision of the physical drive.
1.3.6.1.4.1.232.5.5.2.1.1.8ColumncpqSasPhyDrvSizeread-onlymandatorySAS Physical Drive Size in MB. This is the size of the physical drive in megabytes. This value is calculated using the value 1,048,576 (2^20) as a megabyte. Dr…
1.3.6.1.4.1.232.5.5.2.1.1.9ColumncpqSasPhyDrvUsedReallocsread-onlymandatorySAS Physical Drive Used Reallocation Sectors. This shows the number of sectors of the reallocation area that have been used by the physical drive over the life…
1.3.6.1.4.1.232.5.5.2.1.1.10ColumncpqSasPhyDrvSerialNumberread-onlymandatorySAS Physical Drive Serial Number. This is the serial number assigned to the physical drive.
1.3.6.1.4.1.232.5.5.2.1.1.11ColumncpqSasPhyDrvMemberLogDrvread-onlymandatoryThe Physical Drive is a Member of a Logical Drive. This is an indication of whether the physical drive is a member of a logical drive. This variable can be in …
1.3.6.1.4.1.232.5.5.2.1.1.12ColumncpqSasPhyDrvRotationalSpeedread-onlymandatorySAS Physical Drive Rotational Speed. The following values are defined: other(1) The agent is unable to determine the rotational speed for this drive. rpm7200(2…
1.3.6.1.4.1.232.5.5.2.1.1.13ColumncpqSasPhyDrvOsNameread-onlymandatorySAS Physical Drive OS Name. The OS name for this SAS physical drive. This field will be a null (size 0) string if the agent does not support OS name.
1.3.6.1.4.1.232.5.5.2.1.1.14ColumncpqSasPhyDrvPlacementread-onlymandatorySAS Physical Drive Placement. The following values are defined: other(1) The agent is unable to determine if the drive is internal or external. internal(2) The…
1.3.6.1.4.1.232.5.5.2.1.1.15ColumncpqSasPhyDrvHotPlugread-onlymandatorySAS Physical Drive Hot Plug Support Status. The following values are defined: other(1) The agent is unable to determine if this drive supports hot plug replace…
1.3.6.1.4.1.232.5.5.2.1.1.16ColumncpqSasPhyDrvTyperead-onlymandatorySAS Physical Drive Type. The following values are defined: other(1) The agent is unable to determine the type for this drive. sas(2) The drive type is Serial A…
1.3.6.1.4.1.232.5.5.2.1.1.17ColumncpqSasPhyDrvSasAddressread-onlymandatorySAS Physical Drive SAS Address. The SAS address this SAS physical drive. A null (size 0) string will be returned if the value cannot be determined.
1.3.6.1.4.1.232.5.5.2.1.1.18ColumncpqSasPhyDrvMediaTyperead-onlymandatorySAS Physical Drive Media Type. The following values are defined: other(1) The instrument agent is unable to determine the physical drive�s media type. rotati…
1.3.6.1.4.1.232.5.5.2.1.1.19ColumncpqSasPhyDrvSSDWearStatusread-onlymandatorySAS Physical Drive Solid State Disk Wear Status. This shows the wear status of the solid state physical drive. The following values are valid for the physical …
1.3.6.1.4.1.232.5.5.2.1.1.20ColumncpqSasPhyDrvPowerOnHoursread-onlymandatorySAS Physical Drive Power On Hours. This is the total number of hours that the physical disk has been powered on. This value will be 4,294,967,295 if the disk p…
1.3.6.1.4.1.232.5.5.2.1.1.21ColumncpqSasPhyDrvSSDPercntEndrnceUsedread-onlymandatorySAS Physical Drive Solid State Percent Endurance Used. This value specifies the hundredths of the percentage of solid state disk life used. The value of this f…
1.3.6.1.4.1.232.5.5.2.1.1.22ColumncpqSasPhyDrvSSDEstTimeRemainingHoursread-onlymandatorySAS Physical Drive Solid State Estimated Time Remaining In Hours. This is the estimated total number of hours that the solid state physical disk has remaining.…
1.3.6.1.4.1.232.5.5.2.1.1.23ColumncpqSasPhyDrvAuthenticationStatusread-onlymandatorySAS Physical Drive Authentication Status. The following values are defined: Other (1) Indicates that the instrument agent can not determine the physical drive`…
1.3.6.1.4.1.232.5.5.2.1.1.24ColumncpqSasPhyDrvSmartCarrierAppFWRevread-onlymandatorySAS Physical Drive Smart Carrier Application Firmware Revision. This displays the physical drive smart carrier application firmware revision number. This value…
1.3.6.1.4.1.232.5.5.2.1.1.25ColumncpqSasPhyDrvSmartCarrierBootldrFWRevread-onlymandatorySAS Physical Drive Smart Carrier Bootloader Firmware Revision. This displays the physical drive smart carrier bootloader firmware revision number. This value w…
1.3.6.1.4.1.232.5.5.2.1.1.26ColumncpqSasPhyDrvCurrTemperatureread-onlymandatorySAS Physical Drive Current Operating Temperature degrees Celsius. A zero (0) indicates that the temperature information is not available.
1.3.6.1.4.1.232.5.5.2.1.1.27ColumncpqSasPhyDrvTemperatureThresholdread-onlymandatorySAS Physical Drive Maximum Operating Temperature in degrees Celsius. A zero (0) indicates that the threshold information is not available.
1.3.6.1.4.1.232.5.5.2.1.1.28ColumncpqSasPhyDrvSsBoxModelread-onlymandatorySAS Physical Drive Box Model. This is a description of the SAS drive box`s model. This can be used for identification purposes.
1.3.6.1.4.1.232.5.5.2.1.1.29ColumncpqSasPhyDrvSsBoxFwRevread-onlymandatorySAS Physical Drive Box Firmware Revision. This is the revision level of the SAS drive box. This can be used for identification purposes.
1.3.6.1.4.1.232.5.5.2.1.1.30ColumncpqSasPhyDrvSsBoxVendorread-onlymandatorySAS Physical Drive Box Vendor This is the SAS drive box`s vendor name. This can be used for identification purposes.
1.3.6.1.4.1.232.5.5.2.1.1.31ColumncpqSasPhyDrvSsBoxSerialNumberread-onlymandatorySAS Physical Drive Box Serial Number. This is the SAS drive box`s serial number which is normally display on the front panel. This can be used for identificati…
1.3.6.1.4.1.232.5.5.3NodecpqSasLogDrv
1.3.6.1.4.1.232.5.5.3.1TablecpqSasLogDrvTablenot-accessiblemandatorySAS Logical Drive Table.
1.3.6.1.4.1.232.5.5.3.1.1RowcpqSasLogDrvEntrynot-accessiblemandatorySAS Logical Drive Entry.
1.3.6.1.4.1.232.5.5.3.1.1.1ColumncpqSasLogDrvHbaIndexread-onlymandatorySAS Logical Drive HBA Index. The controller index indicates to which SAS adapter instance this table entry belongs.
1.3.6.1.4.1.232.5.5.3.1.1.2ColumncpqSasLogDrvIndexread-onlymandatorySAS Logical Drive Index. The logical drive index indicates to which logical drive instance this table entry belongs.
1.3.6.1.4.1.232.5.5.3.1.1.3ColumncpqSasLogDrvRaidLevelread-onlymandatorySAS Logical Drive RAID Level. The following RAID levels are defined: other(1) The agent cannot determine the RAID level of this logical drive. raid0(2) The log…
1.3.6.1.4.1.232.5.5.3.1.1.4ColumncpqSasLogDrvStatusread-onlymandatorySAS Logical Drive Status. The logical drive can be in one of the following states: other(1) The management agent does not recognize the status. You may need to…
1.3.6.1.4.1.232.5.5.3.1.1.5ColumncpqSasLogDrvConditionread-onlymandatorySAS Logical Drive Condition. This is the condition of the logical drive.
1.3.6.1.4.1.232.5.5.3.1.1.6ColumncpqSasLogDrvRebuildingDiskread-onlymandatorySAS Logical Drive Rebuilding Disk. This is the disk that is in the process of rebuilding. If no drive is currently rebuilding, a value of -1 will be returned.
1.3.6.1.4.1.232.5.5.3.1.1.7ColumncpqSasLogDrvCapacityread-onlymandatorySAS Logical Drive Size. This is the capacity of the logical drive in megabytes. This value is calculated using the value 1,048,576 (2^20) as a megabyte. Drive …
1.3.6.1.4.1.232.5.5.3.1.1.8ColumncpqSasLogDrvStripeSizeread-onlymandatorySAS Logical Drive Stripe Size. This is the size of a logical drive stripe in kilobytes.
1.3.6.1.4.1.232.5.5.3.1.1.9ColumncpqSasLogDrvPhyDrvIdsread-onlymandatorySAS Logical Drive Physical Drive IDs. This lists the physical drive ID`s associated with this logical drive. Each 4 octets of the string can be used as an inde…
1.3.6.1.4.1.232.5.5.3.1.1.10ColumncpqSasLogDrvSpareIdsread-onlymandatorySAS Logical Drive Spare Drive IDs. This lists the spare drive ID`s associated with this logical drive. Each 4 octets of the string can be used as an index (cpq…
1.3.6.1.4.1.232.5.5.3.1.1.11ColumncpqSasLogDrvOsNameread-onlymandatorySAS Logical Drive OS Name. This is the OS name for the logical drive. This field will be a null (size 0) string if the agent does not support OS name.
1.3.6.1.4.1.232.5.5.3.1.1.12ColumncpqSasLogDrvRebuildingPercentread-onlymandatoryLogical Drive Percent Rebuild. After a failed physical drive has been replaced, the physical drive must have its data rebuilt. This value is the percent comple…
1.3.6.1.4.1.232.5.5.4NodecpqSasTapeDrv
1.3.6.1.4.1.232.5.5.4.1TablecpqSasTapeDrvTablenot-accessiblemandatorySAS Physical Drive Table.
1.3.6.1.4.1.232.5.5.4.1.1RowcpqSasTapeDrvEntrynot-accessiblemandatorySAS Physical Drive Entry.
1.3.6.1.4.1.232.5.5.4.1.1.1ColumncpqSasTapeDrvHbaIndexread-onlymandatorySAS Tape Drive HBA Index. The HBA index indicates to which SAS adapter instance this table entry belongs.
1.3.6.1.4.1.232.5.5.4.1.1.2ColumncpqSasTapeDrvIndexread-onlymandatorySAS Tape Drive Index. The tape drive index indicates to which tape drive instance this table entry belongs.
1.3.6.1.4.1.232.5.5.4.1.1.3ColumncpqSasTapeDrvLocationStringread-onlymandatorySAS Tape Drive Location String. This string describes the location of the drive in relation to the HBA. If the location string cannot be determined, the agent …
1.3.6.1.4.1.232.5.5.4.1.1.4ColumncpqSasTapeDrvNameread-onlymandatorySAS Tape Drive Name. This is a combination of the vendor ID and the product ID as returned by the SCSI inquiry command. This can be used for identification pur…
1.3.6.1.4.1.232.5.5.4.1.1.5ColumncpqSasTapeDrvStatusread-onlymandatorySAS Physical Drive Status. The physical drive can be in one of the following states: other(1) The tape drive is in a state other than one of those listed below…
1.3.6.1.4.1.232.5.5.4.1.1.6ColumncpqSasTapeDrvConditionread-onlymandatorySAS Tape Drive Condition. This is the overall condition of the tape drive. The following values are defined: other(1) The agent does not recognize the status. …
1.3.6.1.4.1.232.5.5.4.1.1.7ColumncpqSasTapeDrvFWRevread-onlymandatorySAS Tape Drive Firmware Revision. This is the firmware revision of the tape drive.
1.3.6.1.4.1.232.5.5.4.1.1.8ColumncpqSasTapeDrvSerialNumberread-onlymandatorySAS Tape Drive Serial Number. This is the serial number assigned to the tape drive.
1.3.6.1.4.1.232.5.5.4.1.1.9ColumncpqSasTapeDrvSasAddressread-onlymandatorySAS Tape Drive SAS Address. The SAS address of this SAS tape drive. A null (size 0) string will be returned if the value cannot be determined.
1.3.6.1.4.1.232.7NodecpqSbScsiBus
1.3.6.1.4.1.232.7.1NodecpqSbScsiMibRev
1.3.6.1.4.1.232.7.1.1ScalarcpqSbMibRevMajorread-onlydeprecatedThe Major Revision level. A change in the major revision level represents a major change in the architecture of the MIB. A change in the major revision level m…
1.3.6.1.4.1.232.7.1.2ScalarcpqSbMibRevMinorread-onlydeprecatedThe Minor Revision level. A change in the minor revision level may represent some minor additional support; no changes to any pre-existing information has occu…
1.3.6.1.4.1.232.7.2NodecpqSbDevice
1.3.6.1.4.1.232.7.2.2TablecpqSbDeviceTablenot-accessibledeprecatedSCSI Drive Bus Table
1.3.6.1.4.1.232.7.2.2.1RowcpqSbDeviceEntrynot-accessibledeprecatedSCSI Drive Bus Entry
1.3.6.1.4.1.232.7.2.2.1.1ColumncpqSbDevCntlrIndexread-onlydeprecatedSCSI Device Bus Controller Index The controller index indicates which SCSI adapter card instance this table entry belongs to. The controller index is the physi…
1.3.6.1.4.1.232.7.2.2.1.2ColumncpqSbDevBusIndexread-onlydeprecatedSCSI Device Bus Index The bus index indicates which SCSI bus instance on an adapter card this table entry belongs to. The instances start at one and increment …
1.3.6.1.4.1.232.7.2.2.1.3ColumncpqSbDevScsiIdIndexread-onlydeprecatedSCSI Device Bus Physical Drive Index The physical drive index indicates which physical drive instance on a SCSI bus this table entry belongs to. The physical d…
1.3.6.1.4.1.232.7.2.2.1.4ColumncpqSbDevTyperead-onlydeprecatedSCSI Device Type This is the type of SCSI device. The following types are defined: other(1) The management agent does not recognize this type. You may need to …
1.3.6.1.4.1.232.7.2.2.1.5ColumncpqSbDevModelread-onlydeprecatedSCSI Device Model This is a description of the physical drive`s model as returned by the SCSI inquiry command. This can be used for identification purposes.
1.3.6.1.4.1.232.7.2.2.1.6ColumncpqSbDevFWRevread-onlydeprecatedSCSI Device Firmware Revision This is the revision level of the physical drive as returned by the SCSI inquiry command. This can be used for identification pur…
1.3.6.1.4.1.232.7.2.2.1.7ColumncpqSbDevVendorread-onlydeprecatedSCSI Device Vendor. This is the physical drive vendor`s name as returned by the SCSI inquiry command. This can be used for identification purposes.
1.3.6.1.4.1.232.7.2.2.1.8ColumncpqSbDevParityErrsread-onlydeprecatedSCSI Device Bus Parity Errors This is the number of parity errors seen on the SCSI bus while processing commands for this SCSI ID since the SCSI Interface Modu…
1.3.6.1.4.1.232.7.2.2.1.9ColumncpqSbDevPhaseErrsread-onlydeprecatedSCSI Device Bus Phase Errors This is the number of times the SCSI bus entered an invalid operating state while processing commands for the SCSI ID since the SC…
1.3.6.1.4.1.232.7.2.2.1.10ColumncpqSbDevSelectTimeoutsread-onlydeprecatedSCSI Device Bus Select Time-outs This is the number of times the controller attempted to start communications with a device by selecting it but the device did …
1.3.6.1.4.1.232.7.2.2.1.11ColumncpqSbDevMsgRejectsread-onlydeprecatedSCSI Device Bus Message Rejects This is the number of times the device rejected a command because it did not support the specified operation since the SCSI Har…
1.3.6.1.4.1.232.7.2.2.1.12ColumncpqSbDevNegPeriodread-onlydeprecatedSCSI Device Negotiated Period This is the amount of time that was negotiated between the controller and the device as a synchronous transfer window. A synchron…
1.3.6.1.4.1.232.7.2.2.1.13ColumncpqSbDevLocationread-onlydeprecatedSCSI Device Location This is the physical location of where the device is located. The following values are defined: other(1) The drives are not located in any…
1.3.6.1.4.1.232.5001NodecpqScsi2CntlrStatusChangeSCSI Controller Status Change. The agent has detected a change in the controller status of a SCSI Controller. The variable cpqScsiCntlrStatus indicates the cur…
1.3.6.1.4.1.232.5002NodecpqScsi2LogDrvStatusChangeLogical Drive Status Change. The agent has detected a change in the Logical Drive Status of a SCSI logical drive. The current logical drive status is indicated…
1.3.6.1.4.1.232.5003NodecpqScsi2PhyDrvStatusChangePhysical Drive Status Change. The agent has detected a change in the status of a SCSI physical drive. The current physical drive status is indicated in the cpq…
1.3.6.1.4.1.232.5004NodecpqTapePhyDrvStatusChangeTape Drive Status Change. The agent has detected a change in the status of a Tape drive. The current physical drive status is indicated in the cpqTapePhyDrvCon…
1.3.6.1.4.1.232.5005NodecpqScsi3CntlrStatusChangeSCSI Controller Status Change. The agent has detected a change in the controller status of a SCSI Controller. The variable cpqScsiCntlrStatus indicates the cur…
1.3.6.1.4.1.232.5006NodecpqScsi3PhyDrvStatusChangePhysical Drive Status Change. The agent has detected a change in the status of a SCSI physical drive. The current physical drive status is indicated in the cpq…
1.3.6.1.4.1.232.5007NodecpqTape3PhyDrvStatusChangeTape Drive Status Change. The agent has detected a change in the status of a Tape drive. The current physical drive status is indicated in the cpqTapePhyDrvCon…
1.3.6.1.4.1.232.5008NodecpqTape3PhyDrvCleaningRequiredTape Drive Cleaning Required trap. The agent has detected a tape drive that needs to have a cleaning tape inserted and run. This will cause the tape drive head…
1.3.6.1.4.1.232.5009NodecpqTape3PhyDrvCleanTapeReplaceTape Drive Cleaning Tape Needs Replacing. The agent has detected that an autoloader tape unit has a cleaning tape that has been fully used and therefore needs …
1.3.6.1.4.1.232.5010NodecpqTape3LibraryFailedTape Library Error The agent has detected that an autoloader unit has an encountered an error.
1.3.6.1.4.1.232.5011NodecpqTape3LibraryOkayTape Library Okay The agent has detected that an autoloader unit has recovered from errors.
1.3.6.1.4.1.232.5012NodecpqTape3LibraryDegradedTape Library Degraded The agent has detected that an autoloader unit is in a degraded condition.
1.3.6.1.4.1.232.5013NodecpqTape3LibraryDoorOpenTape Library Door Open The agent has detected that the door on an autoloader is open so the unit is not operational.
1.3.6.1.4.1.232.5014NodecpqTape3LibraryDoorClosedTape Library Door Closed The agent has detected that the door on a an autoloader has closed.
1.3.6.1.4.1.232.5015NodecpqScsiCdLibraryStatusChangeCD Library Status Change. The agent has detected a change in the status of a CD Library device. The current CD Library status is indicated in the cpqScsiCdLibr…
1.3.6.1.4.1.232.5016NodecpqTape4PhyDrvStatusChangeTape Drive Status Change. The Storage Agent has detected a change in the status of a Tape drive. The current physical drive status is indicated in the cpqTapeP…
1.3.6.1.4.1.232.5017NodecpqScsi4PhyDrvStatusChangePhysical Drive Status Change. The Storage Agent has detected a change in the status of a SCSI physical drive. The current physical drive status is indicated in…
1.3.6.1.4.1.232.5018NodecpqTapeLibraryStatusChangeTape Library Status Change The Storage Agent has detected a change in the status of a tape library. The current tape library status is indicated in the cpqTape…
1.3.6.1.4.1.232.5019NodecpqTape5PhyDrvStatusChangeTape Drive Status Change. The Storage Agent has detected a change in the status of a tape drive. The current physical drive status is indicated in the cpqTapeP…
1.3.6.1.4.1.232.5020NodecpqScsi5PhyDrvStatusChangePhysical Drive Status Change. The Storage Agent has detected a change in the status of a SCSI physical drive. The current physical drive status is indicated in…
1.3.6.1.4.1.232.5021NodecpqScsi3LogDrvStatusChangeLogical Drive Status Change. The Storage Agent has detected a change in the status of a SCSI logical drive. The current logical drive status is indicated in th…
1.3.6.1.4.1.232.5022NodecpqSasPhyDrvStatusChangePhysical Drive Status Change. The Storage Agent has detected a change in the status of a SAS or SATA physical drive. The current physical drive status is indic…
1.3.6.1.4.1.232.5023NodecpqSasLogDrvStatusChangeLogical Drive Status Change. The Storage Agent has detected a change in the status of a SAS or SATA logical drive. The current logical drive status is indicate…
1.3.6.1.4.1.232.5025NodecpqSas2TapeDrvStatusChangeSAS Tape Drive Status Change. The Storage Agent has detected a change in the status of a SAS tape drive. The current tape drive status is indicated in the cpqS…
1.3.6.1.4.1.232.5026NodecpqSasPhyDrvSSDWearStatusChangeSolid State Disk Wear Status Change. This trap signifies that the agent has detected a change in the SSD wear status of a SAS or SATA physical drive. The varia…