CPQSINFO-MIB

263 objects
No module-level DESCRIPTION found.
Imported Objects
CPQHOST-MIBcompaq cpqHoTrapFlags
RFC-1212OBJECT-TYPE
RFC-1215TRAP-TYPE
RFC1213-MIBDisplayString sysName
OIDNameAccessStatusDescription
1.3.6.1.4.1.232.2NodecpqSystemInfo
1.3.6.1.4.1.232.2.1NodecpqSiMibRev
1.3.6.1.4.1.232.2.1.1ScalarcpqSiMibRevMajorread-onlymandatoryThe major revision level of the MIB. A change in the major revision level represents a major change in the architecture of the MIB. A change in the major revis…
1.3.6.1.4.1.232.2.1.2ScalarcpqSiMibRevMinorread-onlymandatoryThe minor revision level of the MIB. A change in the minor revision level may represent some minor additional support, no changes to any pre-existing informati…
1.3.6.1.4.1.232.2.1.3ScalarcpqSiMibConditionread-onlymandatoryThe overall condition. This object represents the overall status of the server information represented by this MIB.
1.3.6.1.4.1.232.2.2NodecpqSiComponent
1.3.6.1.4.1.232.2.2.1NodecpqSiInterface
1.3.6.1.4.1.232.2.2.1.4NodecpqSiOsCommon
1.3.6.1.4.1.232.2.2.1.4.1ScalarcpqSiOsCommonPollFreqread-writemandatoryThe Insight Agent`s polling frequency. The frequency, in seconds, at which the Insight Agent requests information from the device driver. A frequency of zero (…
1.3.6.1.4.1.232.2.2.1.4.2TablecpqSiOsCommonModuleTablenot-accessibledeprecatedA table of software modules that provide an interface to the device this MIB describes.
1.3.6.1.4.1.232.2.2.1.4.2.1RowcpqSiOsCommonModuleEntrynot-accessibledeprecatedA description of a software module that provides an interface to the device this MIB describes.
1.3.6.1.4.1.232.2.2.1.4.2.1.1ColumncpqSiOsCommonModuleIndexread-onlydeprecatedA unique index for this module description.
1.3.6.1.4.1.232.2.2.1.4.2.1.2ColumncpqSiOsCommonModuleNameread-onlydeprecatedThe module name.
1.3.6.1.4.1.232.2.2.1.4.2.1.3ColumncpqSiOsCommonModuleVersionread-onlydeprecatedThe module version in XX.YY format. Where XX is the major version number and YY is the minor version number. This field will be a null (size 0) string if the a…
1.3.6.1.4.1.232.2.2.1.4.2.1.4ColumncpqSiOsCommonModuleDateread-onlydeprecatedThe module date. field octets contents range ===== ====== ======= ===== 1 1-2 year 0..65536 2 3 month 1..12 3 4 day 1..31 4 5 hour 0..23 5 6 minute 0..59 6 7 s…
1.3.6.1.4.1.232.2.2.1.4.2.1.5ColumncpqSiOsCommonModulePurposeread-onlydeprecatedThe purpose of the module described in this entry.
1.3.6.1.4.1.232.2.2.2NodecpqSiAsset
1.3.6.1.4.1.232.2.2.2.1ScalarcpqSiSysSerialNumread-onlymandatoryThe serial number of the physical system unit. The string will be empty if the system does not report the serial number function.
1.3.6.1.4.1.232.2.2.2.2ScalarcpqSiFormFactorread-writemandatoryThe form factor of the system. Setting this variable to unknown will fail.
1.3.6.1.4.1.232.2.2.2.3ScalarcpqSiAssetTagread-writemandatoryThe customer changeable identifier that is set to the system serial number at the time of manufacture. The string will be empty if the system does not report t…
1.3.6.1.4.1.232.2.2.2.4ScalarcpqSiOwnershipTagread-onlymandatoryThis is a customer changeable identifier that will be displayed by ROM at POST. This is an 80 byte standard ASCII character string and is Administrator Passwor…
1.3.6.1.4.1.232.2.2.2.5ScalarcpqSiSysServiceNumread-onlymandatoryThe service number of the system unit. The string will be empty if the system does not report the system service number.
1.3.6.1.4.1.232.2.2.2.6ScalarcpqSiSysProductIdread-onlymandatoryThe product id string of the system unit. The string will be empty if the system does not report the product id.
1.3.6.1.4.1.232.2.2.2.7ScalarcpqSiAssetTagMaxLengthread-onlyoptionalMaximum allowed size in bytes of the asset tag.
1.3.6.1.4.1.232.2.2.2.8TablecpqSiVirtualSystemTablenot-accessibleoptionalA table of virtual system information entries.
1.3.6.1.4.1.232.2.2.2.8.1RowcpqSiVirtualSystemEntrynot-accessibleoptionalA virtual system information table entry.
1.3.6.1.4.1.232.2.2.2.8.1.1ColumncpqSiVirtualSystemIndexread-onlyoptionalThe unique index of the virtual system information entry.
1.3.6.1.4.1.232.2.2.2.8.1.2ColumncpqSiVirtualSystemSerialNumberread-onlyoptionalThe HP Virtual Serial Number for the computer system package. The Virtual Serial Number is the system serial number exposed to the operating system when runnin…
1.3.6.1.4.1.232.2.2.2.8.1.3ColumncpqSiVirtualSystemUUIDread-onlyoptionalThe HP Virtual UUID for the computer system package. The Virtual UUID is the UUID number exposed to the operating system when running in an HP Virtual Connect …
1.3.6.1.4.1.232.2.2.3NodecpqSiSecurity
1.3.6.1.4.1.232.2.2.3.1ScalarcpqSiPowerOnPasswordread-onlymandatoryThe state of the power on password feature.
1.3.6.1.4.1.232.2.2.3.2ScalarcpqSiNetServerModeread-onlymandatoryThe state of the network server mode feature.
1.3.6.1.4.1.232.2.2.3.3ScalarcpqSiQuickLockPasswordread-onlymandatoryThe state of the quicklock password feature.
1.3.6.1.4.1.232.2.2.3.4ScalarcpqSiQuickBlankread-onlymandatoryThe state of the quick blank screen feature.
1.3.6.1.4.1.232.2.2.3.5ScalarcpqSiDisketteBootControlread-onlymandatoryThe state of the diskette boot control feature.
1.3.6.1.4.1.232.2.2.3.6ScalarcpqSiSerialPortAControlread-onlymandatoryThe state of the access control for the primary serial port interface embedded in the system board.
1.3.6.1.4.1.232.2.2.3.7ScalarcpqSiSerialPortBControlread-onlymandatoryThe state of the access control for the secondary serial port interface embedded in the system board.
1.3.6.1.4.1.232.2.2.3.8ScalarcpqSiParallelPortControlread-onlymandatoryThe state of the access control for the parallel port interface embedded in the system board.
1.3.6.1.4.1.232.2.2.3.9ScalarcpqSiFloppyDiskControlread-onlymandatoryThe state of the access control for the floppy diskette interface embedded in the system board.
1.3.6.1.4.1.232.2.2.3.10ScalarcpqSiFixedDiskControlread-onlymandatoryThe state of the access control for the fixed disk interface embedded in the system board.
1.3.6.1.4.1.232.2.2.3.11ScalarcpqSiHoodRemovedTimeread-onlymandatoryLast detection of hood removed by Smart Hood Sensor.
1.3.6.1.4.1.232.2.2.3.12ScalarcpqSiHoodSensorConfigurationread-onlymandatoryThis is the current configuration of the Smart Cover sensor. The following values are currently defined: other(1) Smart Cover sensor is not supported on this s…
1.3.6.1.4.1.232.2.2.3.13ScalarcpqSiSmartCoverLockStatusread-onlymandatoryThis is the current status of the Smart Cover Lock. The following values are currently defined: other(1) Smart Cover Lock is not supported on this system or ca…
1.3.6.1.4.1.232.2.2.3.14ScalarcpqSiUSBPortControlread-onlymandatoryThe state of the access control for the Universal Serial Bus interface(s) embedded in the system board. other(1) If Status could not be determined. disabled(2)…
1.3.6.1.4.1.232.2.2.3.15ScalarcpqSiVirtualSerialPortControlread-onlymandatoryThe state of the access control for the virtual serial port interface embedded in the system board.
1.3.6.1.4.1.232.2.2.3.16ScalarcpqSiChassisHoodStatusread-onlymandatoryThe status of the chassis intrusion alert hardware and the hood presence. unknown (1) Unable to determine the system intrusion alert hardware presence. not-ins…
1.3.6.1.4.1.232.2.2.4NodecpqSiSystemBoard
1.3.6.1.4.1.232.2.2.4.1ScalarcpqSiProductIdread-onlymandatoryThe machine product ID. This value indicates the product type of the system board in this system. The value 127 will be given if the machine ID cannot be deter…
1.3.6.1.4.1.232.2.2.4.2ScalarcpqSiProductNameread-onlymandatoryThe machine product name. The name of the machine used in this system.
1.3.6.1.4.1.232.2.2.4.4ScalarcpqSiAuxiliaryInputread-onlymandatoryThe state of the auxiliary input (pointing) device.
1.3.6.1.4.1.232.2.2.4.5TablecpqSiMemModuleTablenot-accessiblemandatoryA table of memory module descriptions.
1.3.6.1.4.1.232.2.2.4.5.1RowcpqSiMemModuleEntrynot-accessiblemandatoryA memory module description.
1.3.6.1.4.1.232.2.2.4.5.1.1ColumncpqSiMemBoardIndexread-onlymandatoryThe slot in which the memory board or cartridge is installed. A value of 0 indicates memory installed directly on the system board.
1.3.6.1.4.1.232.2.2.4.5.1.2ColumncpqSiMemModuleIndexread-onlymandatoryThe memory module number.
1.3.6.1.4.1.232.2.2.4.5.1.3ColumncpqSiMemModuleSizeread-onlymandatoryModule memory size in kilobytes. A kilobyte of memory is defined as 1024 bytes. A size of 0 indicates the module is not present.
1.3.6.1.4.1.232.2.2.4.5.1.4ColumncpqSiMemModuleTyperead-onlymandatoryType of memory module installed. The value other(1) will be given if the type is not known. The value board(2) will be given if the memory module is permanentl…
1.3.6.1.4.1.232.2.2.4.5.1.5ColumncpqSiMemModuleSpeedread-onlydeprecatedModule memory speed in nanoseconds. The value zero (0) will be given if the module speed cannot be determined.
1.3.6.1.4.1.232.2.2.4.5.1.6ColumncpqSiMemModuleTechnologyread-onlymandatoryTechnology type of memory module installed. The value other(1) will be given if the technology is not known.
1.3.6.1.4.1.232.2.2.4.5.1.7ColumncpqSiMemModuleManufacturerread-onlymandatoryThe memory module`s manufacturer name. This field will be a null (size 0) string if the manufacturer name is not available.
1.3.6.1.4.1.232.2.2.4.5.1.8ColumncpqSiMemModulePartNoread-onlymandatoryThe memory module`s manufacturer part number. This field will be a null (size 0) string if the manufacturer part number is not available.
1.3.6.1.4.1.232.2.2.4.5.1.9ColumncpqSiMemModuleDateread-onlymandatoryThe memory module date of manufacture. field octets contents range ===== ====== ====================== ======== 1 1-2 year 0..65536 2 3 month 1..12 3 4 day 1..…
1.3.6.1.4.1.232.2.2.4.5.1.10ColumncpqSiMemModuleSerialNoread-writemandatoryThe memory module`s serial number. This field will be a null (size 0) string if the serial number is not available.
1.3.6.1.4.1.232.2.2.4.5.1.11ColumncpqSiMemModuleECCStatusread-onlymandatoryThis provides the current status of the correctable memory errors for this memory module. The following status values are supported: other(1): ECC is not suppo…
1.3.6.1.4.1.232.2.2.4.5.1.12ColumncpqSiMemModuleHwLocationread-onlyoptionalA text description of the hardware location, on complex multi SBB hardware only, for the memory module. A NULL string indicates that the hardware location coul…
1.3.6.1.4.1.232.2.2.4.5.1.13ColumncpqSiMemModuleFrequencyread-onlymandatoryThe memory module frequency in MHz. The value zero (0) will be given if the module frequency cannot be determined.
1.3.6.1.4.1.232.2.2.4.5.1.14ColumncpqSiMemModuleCellTablePtrread-onlyoptionalIndex for the cell in cpqSeCellTable where the memory board is installed.
1.3.6.1.4.1.232.2.2.4.5.1.15ColumncpqSiMemModuleCellStatusread-onlyoptionalThis provides the current status for this memory module. The following status values are supported: other(1): The memory module status is not available ok(2): …
1.3.6.1.4.1.232.2.2.4.5.1.16ColumncpqSiMemModulePartNoMfgrread-onlyoptionalThe memory module`s manufacturer`s part number. This field will be a null (size 0) string if the manufacturer part number is not available.
1.3.6.1.4.1.232.2.2.4.5.1.17ColumncpqSiMemModuleSerialNoMfgrread-onlyoptionalThe memory module`s manufacturer`s serial number. This field will be a null (size 0) string if the manufacturer serial number is not available.
1.3.6.1.4.1.232.2.2.4.6ScalarcpqSiSystemIdread-onlymandatoryThe System ID. This value indicates the system ID of the system board in this system. This ID replaces the product ID used in older machines (cpqSiProductId). …
1.3.6.1.4.1.232.2.2.4.7ScalarcpqSiSystemCpuIdread-onlymandatoryThe System ID : CPU Component. This value indicates the CPU type of the system board in this system. A value of zero (0) indicates that the CPU type cannot be …
1.3.6.1.4.1.232.2.2.4.8ScalarcpqSiFlashRomSupportread-onlymandatoryThis value indicates if this system supports flash upgradable system ROM.
1.3.6.1.4.1.232.2.2.4.9ScalarcpqSiQuickTestRomDateread-onlymandatoryThis value indicates the date of the current quick test ROM image. field octets contents range ===== ====== ======= ===== 1 1-2 year 0..65536 2 3 month 1..12 3…
1.3.6.1.4.1.232.2.2.4.10ScalarcpqSiRebootread-writedeprecatedThis object may contain the following values: notAvailable(1) the system does not support the reboot functionality. Setting this object to notAvailable(1) has …
1.3.6.1.4.1.232.2.2.4.11TablecpqSiProcMicroPatchTablenot-accessiblemandatoryThis table lists the set of processor microcode patches that the system ROM contains. During post, the ROM will apply the appropriate patches to the CPU microc…
1.3.6.1.4.1.232.2.2.4.11.1RowcpqSiProcMicroPatchEntrynot-accessiblemandatoryAn entry describing one microcode patch contained in the system ROM.
1.3.6.1.4.1.232.2.2.4.11.1.1ColumncpqSiProcMicroPatchIndexread-onlymandatoryIndex into the microcode patch table.
1.3.6.1.4.1.232.2.2.4.11.1.2ColumncpqSiProcMicroPatchIdread-onlymandatoryThe ID of this particular CPU microcode patch.
1.3.6.1.4.1.232.2.2.4.11.1.3ColumncpqSiProcMicroPatchDateread-onlymandatoryThis value indicates the date of this CPU microcode patch. field octets contents range ===== ====== ======= ===== 1 1-2 year 0..65536 2 3 month 1..12 3 4 day 1…
1.3.6.1.4.1.232.2.2.4.11.1.4ColumncpqSiProcMicroPatchFamilyread-onlymandatoryThe valid family/model/step of the processor that this CPU microcode patch applies to. field octets contents range ===== ====== ======= ===== 1 1 CPU Step 0..2…
1.3.6.1.4.1.232.2.2.4.12ScalarcpqSiPowerMgmtStatusread-onlymandatoryThe state of power management.
1.3.6.1.4.1.232.2.2.4.13ScalarcpqSiRebootFlagsread-writemandatoryThe Reboot Flags. This is a collection of flags used to indicate the re-boot options available. This integer is a bitmap, with each bit indicating the availabi…
1.3.6.1.4.1.232.2.2.4.14ScalarcpqSiMemErrorIndexread-onlymandatoryPlaceholder for memory module number for ECC traps. Represents the number of the memory module for which an ECC status change has occurred. Set to 65535 if mod…
1.3.6.1.4.1.232.2.2.4.15ScalarcpqSiMemECCConditionread-onlymandatoryThis provides the current condition of the correctable memory errors for the entire memory. The following status values are supported: other(1) : ECC is not su…
1.3.6.1.4.1.232.2.2.4.16ScalarcpqSiMemConfigChangeDataread-onlymandatoryText string for the memory configuration change trap.
1.3.6.1.4.1.232.2.2.4.17ScalarcpqSiServerSystemIdread-onlymandatoryA Server System ID. This value is used to uniquely identify systems via a unique ID on systems that do not support the EISA bus.
1.3.6.1.4.1.232.2.2.4.18ScalarcpqSiPowerSchemeread-onlyoptionalThe current active power plan or power scheme of the system.
1.3.6.1.4.1.232.2.2.4.19ScalarcpqSiPowerSchemeNameread-onlyoptionalThe name of current active power plan or power scheme of the system. When cpqSiPowerScheme has a value of user-defined(6), the user defined name can be populat…
1.3.6.1.4.1.232.2.2.4.20ScalarcpqSiCurrentPerformanceStatePointerread-onlyoptionalPointer to cpqSiPerfStateIndex in cpqSiPerfStateTable to indicate the current performance state of the system.
1.3.6.1.4.1.232.2.2.4.21ScalarcpqSiMinPerformanceStateread-onlyoptionalThe slowest performance state by the selected power state policy.
1.3.6.1.4.1.232.2.2.4.22ScalarcpqSiMaxPerformanceStateread-onlyoptionalThe fastest performance state supported by the selected power state policy.
1.3.6.1.4.1.232.2.2.4.23TablecpqSiPerfStateTablenot-accessibleoptionalA table of supported performance states of the system.
1.3.6.1.4.1.232.2.2.4.23.1RowcpqSiPerfStateEntrynot-accessibleoptionalAn entry describing a supported performance state of the system.
1.3.6.1.4.1.232.2.2.4.23.1.1ColumncpqSiPerfStateIndexread-onlyoptionalIndex into the performance state table. cpqSiCurrentPerformanceStatePointer should point to one of these values.
1.3.6.1.4.1.232.2.2.4.23.1.2ColumncpqSiPerfStateread-onlyoptionalPerformance state number. A unique number assigned to a performance state instance.
1.3.6.1.4.1.232.2.2.4.23.1.3ColumncpqSiPerfStateCpuFrequencyread-onlyoptionalThe processor frequency in megahertz for this performance state instance.
1.3.6.1.4.1.232.2.2.4.23.1.4ColumncpqSiPerfStateCpuPowerread-onlyoptionalThe processor power setting in milliwatts for this performance state instance.
1.3.6.1.4.1.232.2.2.4.24ScalarcpqSiTPMmoduleread-onlyoptionalThis field will be populated if TPM module is present in the system board. other(1) No record of TPM exist. absent(2) TPM module is not present in the system. …
1.3.6.1.4.1.232.2.2.4.25ScalarcpqSiTrustedModuleTyperead-onlyoptionalBits[3:0] = Trusted Module Type: 1h = Not Specified 2h = TPM 1.2 3h = TPM 2.0 4h = TM 1.0 5h - 0Fh = Reserved.
1.3.6.1.4.1.232.2.2.4.26ScalarcpqSiSystemTelemetryMetricread-onlyoptionalThis field specifies the system telemetry metric type. CPU Utilization(1) Overall CPU utilization of the system. Memory Bus Utilization(2) Memory Bus utilizati…
1.3.6.1.4.1.232.2.2.4.27ScalarcpqSiSystemTelemetryThresholdStatusread-onlyoptionalThis field corresponds to the threshold(upper/lower) breach condition of the metric. Above Upper Threshold(1) The value has exceeded upper threshold. Below Low…
1.3.6.1.4.1.232.2.2.5NodecpqSiBoardRev
1.3.6.1.4.1.232.2.2.5.1ScalarcpqSiCurRevDateread-onlymandatoryThe current board revision configuration date in MM/DD/YY format. This is the date that the EISA Configuration Utility was used to define the current configura…
1.3.6.1.4.1.232.2.2.5.2ScalarcpqSiPrevRevDateread-onlymandatoryThe previous board revision configuration date in MM/DD/YY format. This is the date that the EISA Configuration Utility was used to define the previous configu…
1.3.6.1.4.1.232.2.2.5.3TablecpqSiBoardRevTablenot-accessiblemandatoryA table of board revision descriptions.
1.3.6.1.4.1.232.2.2.5.3.1RowcpqSiBoardRevEntrynot-accessiblemandatoryA board revision description.
1.3.6.1.4.1.232.2.2.5.3.1.1ColumncpqSiBoardRevSlotIndexread-onlymandatoryThe slot in which the board described in this entry resides. Zero (0) indicates the system board.
1.3.6.1.4.1.232.2.2.5.3.1.2ColumncpqSiBoardRevIndexread-onlymandatoryA number that uniquely specifies which board in a specific slot is described in this entry. Zero (0) indicates the main board in this slot. Any other number in…
1.3.6.1.4.1.232.2.2.5.3.1.3ColumncpqSiBoardRevIdread-onlymandatoryA description of the board type. The defined types are: Type ============== System Board Processor n (n = the processor number) Memory n (n = the memory board …
1.3.6.1.4.1.232.2.2.5.3.1.4ColumncpqSiBoardRevCurread-onlymandatoryThe current revision for the board described in this entry. This value will be N/A if there is no current revision information.
1.3.6.1.4.1.232.2.2.5.3.1.5ColumncpqSiBoardRevPrevread-onlymandatoryThe revision for the board described in this entry prior to the current configuration. This value will be N/A if there is no previous revision information.
1.3.6.1.4.1.232.2.2.5.3.1.6ColumncpqSiBoardRevHwLocationread-onlyoptionalA text description of the hardware location, on complex multi SBB hardware only, for the board. A NULL string indicates that the hardware location could not be…
1.3.6.1.4.1.232.2.2.5.4TablecpqSiFirmwareRevTablenot-accessiblemandatoryA table of firmware revision descriptions.
1.3.6.1.4.1.232.2.2.5.4.1RowcpqSiFirmwareRevEntrynot-accessiblemandatoryA firmware revision description.
1.3.6.1.4.1.232.2.2.5.4.1.1ColumncpqSiFirmwareRevIndexread-onlymandatoryLocally-unique index for this entry.
1.3.6.1.4.1.232.2.2.5.4.1.2ColumncpqSiFirmwareRevDescread-onlymandatoryDescription, e.g. SRM console, ARC console, System BIOS, etc.
1.3.6.1.4.1.232.2.2.5.4.1.3ColumncpqSiFirmwareRevStringread-onlymandatoryVersion number, possibly of the form Vx.y or Vx.y-z.
1.3.6.1.4.1.232.2.2.5.4.1.4ColumncpqSiFirmwareRevCellTablePtrread-onlydeprecatedIndex for the cell in cpqSeCellTable where this firmware is located
1.3.6.1.4.1.232.2.2.5.4.1.5ColumncpqSiFirmwareLocationread-onlyoptionalDescription of which board the firmware is located in.
1.3.6.1.4.1.232.2.2.5.4.1.6ColumncpqSiFirmwareStatusread-onlyoptionalThe current status for this firmware.
1.3.6.1.4.1.232.2.2.5.5TablecpqSiFirmwareCfgTablenot-accessiblemandatoryTable of soft switches and symbols maintained by the firmware. May be operating system and/or option-specific and will certainly be system-specific. This list …
1.3.6.1.4.1.232.2.2.5.5.1RowcpqSiFirmwareCfgEntrynot-accessiblemandatoryEach entry represents one variable or symbol maintained by or stored by some instance of firmware in the system.
1.3.6.1.4.1.232.2.2.5.5.1.1ColumncpqSiFirmwareCfgNameread-onlymandatoryThe firmware configuration symbol name as visible from the console.
1.3.6.1.4.1.232.2.2.5.5.1.2ColumncpqSiFirmwareCfgValueread-onlymandatoryThe firmware configuration symbol value. Null if none or unknown.
1.3.6.1.4.1.232.2.2.6NodecpqSiRackServer
1.3.6.1.4.1.232.2.2.6.1ScalarcpqSiRackServerShutdownRoleread-writemandatoryThis entry describes this system`s role in a rack-mounted uninterruptible power supply family. The master both communicates with the UPS and derives its power …
1.3.6.1.4.1.232.2.2.6.2ScalarcpqSiRackServerMasterNameread-writemandatoryThis entry describes the name of the master server in a rack-mounted uninterruptible power supply family. A slave system would communicate with this server to …
1.3.6.1.4.1.232.2.2.7NodecpqSiVideo
1.3.6.1.4.1.232.2.2.7.1ScalarcpqSiVideoEdidRawread-onlydeprecatedThe raw value returned from the video EDID function.
1.3.6.1.4.1.232.2.2.7.2ScalarcpqSiVideoDescread-onlydeprecatedThe manufacturer and model description of the video display.
1.3.6.1.4.1.232.2.2.7.3ScalarcpqSiVideoSerialNumberread-onlydeprecatedThe serial number of the video display.
1.3.6.1.4.1.232.2.2.7.4ScalarcpqSiVideoManufactureDateread-onlydeprecatedThe date of manufacture of the video display in the following format: field octets contents range ===== ====== ======= ===== 1 1-2 year 0..65536 2 3 month 1..1…
1.3.6.1.4.1.232.2.2.7.5ScalarcpqSiVideoHeightread-onlydeprecatedThe maximum image height of the video display in centimeters
1.3.6.1.4.1.232.2.2.7.6ScalarcpqSiVideoWidthread-onlydeprecatedThe maximum image width of the video display in centimeters
1.3.6.1.4.1.232.2.2.7.7ScalarcpqSiVideoMaxHorPixelread-onlydeprecatedThe number of horizontal pixels in the highest resolution video mode supported.
1.3.6.1.4.1.232.2.2.7.8ScalarcpqSiVideoMaxVertPixelread-onlydeprecatedThe number of vertical pixels in the highest resolution video mode supported.
1.3.6.1.4.1.232.2.2.7.9ScalarcpqSiVideoMaxRefreshRateread-onlydeprecatedThe video refresh rate in Hz of the highest resolution video mode supported.
1.3.6.1.4.1.232.2.2.8NodecpqSiMonitor
1.3.6.1.4.1.232.2.2.8.1ScalarcpqSiMonitorOverallConditionread-onlymandatoryThis value specifies the overall condition of the system`s monitor(s). The following conditions are supported: other(1) The monitor does not support fault repo…
1.3.6.1.4.1.232.2.2.8.2TablecpqSiMonitorTablenot-accessiblemandatoryA table of all video monitor descriptions connected to this system.
1.3.6.1.4.1.232.2.2.8.2.1RowcpqSiMonitorEntrynot-accessiblemandatoryA video monitor description.
1.3.6.1.4.1.232.2.2.8.2.1.1ColumncpqSiMonitorIndexread-onlymandatoryA unique index for each video display connected to the system.
1.3.6.1.4.1.232.2.2.8.2.1.2ColumncpqSiMonitorEdidRawread-onlymandatoryThe raw value returned from the video EDID function.
1.3.6.1.4.1.232.2.2.8.2.1.3ColumncpqSiMonitorDescread-onlymandatoryThe manufacturer and model description of the video display.
1.3.6.1.4.1.232.2.2.8.2.1.4ColumncpqSiMonitorSerialNumberread-onlymandatoryThe serial number of the video display.
1.3.6.1.4.1.232.2.2.8.2.1.5ColumncpqSiMonitorManufactureDateread-onlymandatoryThe date of manufacture of the video display in the following format: field octets contents range ===== ====== ======= ===== 1 1-2 year 0..65536 2 3 month 1..1…
1.3.6.1.4.1.232.2.2.8.2.1.6ColumncpqSiMonitorHeightread-onlymandatoryThe maximum image height of the video display in centimeters
1.3.6.1.4.1.232.2.2.8.2.1.7ColumncpqSiMonitorWidthread-onlymandatoryThe maximum image width of the video display in centimeters
1.3.6.1.4.1.232.2.2.8.2.1.8ColumncpqSiMonitorMaxHorPixelread-onlymandatoryThe number of horizontal pixels in the highest resolution video mode supported.
1.3.6.1.4.1.232.2.2.8.2.1.9ColumncpqSiMonitorMaxVertPixelread-onlymandatoryThe number of vertical pixels in the highest resolution video mode supported.
1.3.6.1.4.1.232.2.2.8.2.1.10ColumncpqSiMonitorMaxRefreshRateread-onlymandatoryThe video refresh rate in Hz of the highest resolution video mode supported.
1.3.6.1.4.1.232.2.2.8.2.1.11ColumncpqSiMonitorManufacturerread-onlymandatoryThe manufacturer of the video display.
1.3.6.1.4.1.232.2.2.8.2.1.12ColumncpqSiMonitorThermalConditionread-onlymandatoryThis provides the condition of the monitor`s internal temperature. This value will be one of the following: other(1) Monitor thermal fault reporting is not sup…
1.3.6.1.4.1.232.2.2.8.2.1.13ColumncpqSiMonitorOperationalConditionread-onlymandatoryThis provides the condition of the monitor`s operational features. This condition value will be one of the following: other(1) Monitor operational fault report…
1.3.6.1.4.1.232.2.2.8.2.1.14ColumncpqSiMonitorStatusread-onlymandatoryThis provides the status of the monitor`s fault reporting features. This status value will be one of the following: other(1) Monitor fault reporting is not sup…
1.3.6.1.4.1.232.2.2.9NodecpqSiHotPlugSlot
1.3.6.1.4.1.232.2.2.9.1ScalarcpqSiHotPlugSlotSupportedread-onlymandatoryThis value specifies if this system supports the Hot Pluggable Slot feature.
1.3.6.1.4.1.232.2.2.9.2ScalarcpqSiHotPlugSlotConditionread-onlymandatoryThis value specifies the overall condition of the Hot Plug Slot feature. The Hot Plug condition is set as follows: other(1) When Hot Plug Slots are not support…
1.3.6.1.4.1.232.2.2.9.3ScalarcpqSiHotPlugSlotChangeCountread-onlymandatoryThis value will be incremented each time a hot plug event occurs resulting in a change in the hot plug slot table.
1.3.6.1.4.1.232.2.2.9.4TablecpqSiHotPlugSlotTablenot-accessiblemandatoryA list of Hot Plug Slot information entries.
1.3.6.1.4.1.232.2.2.9.4.1RowcpqSiHotPlugSlotEntrynot-accessiblemandatoryA description of a Hot Plug Slot.
1.3.6.1.4.1.232.2.2.9.4.1.1ColumncpqSiHotPlugSlotChassisread-onlymandatoryThe Chassis where this hot plug slot resides.
1.3.6.1.4.1.232.2.2.9.4.1.2ColumncpqSiHotPlugSlotIndexread-onlymandatoryThe slot within the chassis for this hot plug slot.
1.3.6.1.4.1.232.2.2.9.4.1.3ColumncpqSiHotPlugSlotBoardPresentread-onlymandatoryThis value indicates whether a board is present(2) in or absent(3) from the slot. A value of other(1) indicates the information could not be obtained.
1.3.6.1.4.1.232.2.2.9.4.1.4ColumncpqSiHotPlugSlotPowerStateread-onlymandatoryThis value is set to powerOn(2) when power is being supplied to the slot and powerOff(3) when power is not being supplied. A value of other(1) indicates the in…
1.3.6.1.4.1.232.2.2.9.4.1.5ColumncpqSiHotPlugSlotBoardConditionread-onlymandatoryThis value specifies the condition of the hot plug slot. The hot plug condition is set as follows: other(1) When the condition could not be determined. ok(2) T…
1.3.6.1.4.1.232.2.2.9.4.1.6ColumncpqSiHotPlugSlotErrorStatusread-onlymandatoryThis value specifies the status of the hot plug slot. The hot plug slot status is set as follows: noError(1) The slot is operating normally. generalError(2) A …
1.3.6.1.4.1.232.2.2.9.4.1.7ColumncpqSiHotPlugSlotHwLocationread-onlyoptionalA text description of the hardware location, on complex multi SBB hardware only, for the hot plug slot. A NULL string indicates that the hardware location coul…
1.3.6.1.4.1.232.2.2.10NodecpqSiSystemBattery
1.3.6.1.4.1.232.2.2.10.1ScalarcpqSiSystemBatteryOverallConditionread-onlymandatoryThis value specifies the overall condition of all of the system batteries. The following conditions are supported: other(1) The system does not use system batt…
1.3.6.1.4.1.232.2.2.10.2TablecpqSiSysBatteryTablenot-accessiblemandatoryA table of System Batteries.
1.3.6.1.4.1.232.2.2.10.2.1RowcpqSiSysBatteryEntrynot-accessiblemandatoryA system battery description.
1.3.6.1.4.1.232.2.2.10.2.1.1ColumncpqSiSysBatteryIndexread-onlymandatoryA unique index for this battery entry.
1.3.6.1.4.1.232.2.2.10.2.1.2ColumncpqSiSysBatteryModelread-onlymandatoryThe model name for this battery.
1.3.6.1.4.1.232.2.2.10.2.1.3ColumncpqSiSysBatterySerialNumread-onlymandatoryThe serial number for this battery.
1.3.6.1.4.1.232.2.2.10.2.1.4ColumncpqSiSysBatteryAssetTagread-onlymandatoryThis is the customer changeable battery identifier that is set to this system battery`s serial number at the time of manufacture. The string will be empty if t…
1.3.6.1.4.1.232.2.2.10.2.1.5ColumncpqSiSysBatteryManufacturerread-onlymandatoryThe battery`s manufacturer`s name. The string will be empty if the battery does support this function.
1.3.6.1.4.1.232.2.2.10.2.1.6ColumncpqSiSysBatteryDateread-onlymandatoryThe battery`s manufacture date. field octets contents range ===== ====== ======= ===== 1 1-2 year 0..65536 2 3 month 1..12 3 4 day 1..31 4 5 hour 0..23 5 6 min…
1.3.6.1.4.1.232.2.2.10.2.1.7ColumncpqSiSysBatterySmartVersionread-onlymandatoryThe Smart Battery Data Specification version number supported by this battery. The string will be empty if the system battery does support this function.
1.3.6.1.4.1.232.2.2.10.2.1.8ColumncpqSiSysBatteryConditionread-onlymandatoryThis provides the current condition of this system battery. The following status values are supported: other(1) The battery does not support condition monitori…
1.3.6.1.4.1.232.2.2.10.2.1.9ColumncpqSiSysBatteryStatusread-onlymandatoryThis provides the current status of the battery. The following status values are supported: other(1): This battery does not support status reporting. ok(2): Th…
1.3.6.1.4.1.232.2.2.10.2.1.10ColumncpqSiSysBatteryChemistryread-onlymandatoryThe chemistry of the battery.
1.3.6.1.4.1.232.2.2.10.2.1.11ColumncpqSiSysBatteryRemainingCapread-onlymandatoryThis is a percentage of the battery`s remaining capacity from its design capacity. If this attribute is not supported, 65535 is returned.
1.3.6.1.4.1.232.2.2.10.2.1.12ColumncpqSiSysBatteryFirmwareRevisionread-onlymandatoryThis is the revision level of the firmware on the battery. If this attribute is not supported, 255 is returned.
1.3.6.1.4.1.232.2.2.10.2.1.13ColumncpqSiSysBatteryHardwareRevisionread-onlymandatoryThis is the revision level of the hardware on the battery. If this attribute is not supported, 255 is returned.
1.3.6.1.4.1.232.2.2.10.2.1.14ColumncpqSiSysBatteryFullCapread-onlymandatoryThis is the mWatt-Hours of the battery`s Full capacity on the current charge. If this attribute is not supported, 65535 is returned.
1.3.6.1.4.1.232.2.2.10.2.1.15ColumncpqSiSysBatteryDesignCapread-onlymandatoryThis is the mWatt-Hours of the battery`s design capacity as specified by the manufacturer. If this attribute is not supported, 65535 is returned.
1.3.6.1.4.1.232.2.2.10.2.1.16ColumncpqSiSysBatteryHwLocationread-onlyoptionalA text description of the hardware location, on complex multi SBB hardware only, for the battery. A NULL string indicates that the hardware location could not …
1.3.6.1.4.1.232.2.2.11NodecpqSiDockingStation
1.3.6.1.4.1.232.2.2.11.1ScalarcpqSiDockingStationStatusread-onlymandatoryThis value specifies the connection of the computer system to a docking station. The following connection states are supported: notSupported(1) This system doe…
1.3.6.1.4.1.232.2.2.11.2ScalarcpqSiDockingStationSerialNumread-onlymandatoryThe serial number of the docking station. The string will be empty if the docking station does not support a serial or the system does not interface to a docki…
1.3.6.1.4.1.232.2.2.11.3ScalarcpqSiDockingStationModelread-onlymandatoryThe model name of the docking station. The string will be empty if the docking station does not report the model name or the system does not interface to a doc…
1.3.6.1.4.1.232.2.2.11.4ScalarcpqSiDockingStationAssetTagread-onlymandatoryThis is a customer changeable identifier that is set to the docking station serial number at the time of manufacture. The string will be empty if the docking s…
1.3.6.1.4.1.232.2.2.12NodecpqSiFru
1.3.6.1.4.1.232.2.2.12.1TablecpqSiFruTablenot-accessiblemandatoryTable of Field Replaceable Units of system, providing inventory and asset control information. This table is referenced from logical hardware descriptions else…
1.3.6.1.4.1.232.2.2.12.1.1RowcpqSiFruEntrynot-accessiblemandatoryEach entry represents a Field Replaceable Unit (FRU) of hardware.
1.3.6.1.4.1.232.2.2.12.1.1.1ColumncpqSiFruIndexread-onlymandatoryA locally-unique index value.
1.3.6.1.4.1.232.2.2.12.1.1.2ColumncpqSiFruTyperead-onlymandatoryGeneral category of the type of FRU that this is.
1.3.6.1.4.1.232.2.2.12.1.1.3ColumncpqSiFruDescrread-writemandatoryMore detailed description of FRU type, if known.
1.3.6.1.4.1.232.2.2.12.1.1.4ColumncpqSiFruVendorread-onlymandatoryManufacturer name or ID.
1.3.6.1.4.1.232.2.2.12.1.1.5ColumncpqSiFruPartNumberread-onlymandatoryNumber by which this unit is orderable.
1.3.6.1.4.1.232.2.2.12.1.1.6ColumncpqSiFruRevisionread-onlymandatoryVersion number of this unit. If artwork level is available, it will appear as `Artwork: XXX` following FRU version portion.
1.3.6.1.4.1.232.2.2.12.1.1.7ColumncpqSiFruFirmwareRevisionread-onlymandatoryThe revision of the firmware, if any. Otherwise null.
1.3.6.1.4.1.232.2.2.12.1.1.8ColumncpqSiFruSerialNumberread-onlymandatoryThe serial number of this unit`s instance.
1.3.6.1.4.1.232.2.2.12.1.1.9ColumncpqSiFruAssetNoread-writemandatoryThe asset number for this unit. This string may be limited.
1.3.6.1.4.1.232.2.2.12.1.1.10ColumncpqSiFruClassread-onlymandatoryRepresents the status category of the unit.
1.3.6.1.4.1.232.2.2.12.1.1.11ColumncpqSiFruSlotNumberread-onlymandatoryPhysical slot number of FRU.
1.3.6.1.4.1.232.2.2.12.1.1.12ColumncpqSiFruSubAssemblyNumberread-onlymandatorySubassembly containing this FRU. From FRU V5.0.
1.3.6.1.4.1.232.2.2.12.1.1.13ColumncpqSiFruAssemblyNumberread-onlymandatoryAssembly containing this FRU. From FRU V5.0.
1.3.6.1.4.1.232.2.2.12.1.1.14ColumncpqSiFruChassisNumberread-onlymandatoryChassis containing this FRU. From FRU V5.0.
1.3.6.1.4.1.232.2.2.12.1.1.15ColumncpqSiFruPositionNumberread-onlymandatoryPosition in Chassis to help locate FRU. From FRU V5.0.
1.3.6.1.4.1.232.2.2.12.1.1.16ColumncpqSiFruCabinetIDNumberread-onlymandatoryCabinet number containing this FRU. From FRU V5.0.
1.3.6.1.4.1.232.2.2.12.1.1.17ColumncpqSiFruSiteLocationread-onlymandatorySite code for system containing this FRU. From FRU V5.0.
1.3.6.1.4.1.232.2.2.12.1.1.18ColumncpqSiFruDiagStatusread-onlymandatoryUse system status values to describe current state of the FRU.
1.3.6.1.4.1.232.2.2.12.1.1.19ColumncpqSiFruExtendedDiagStatusread-onlymandatoryDiagnostic Status value returned by Device Specific diagnostics. Usually through a diagnostic status register on the device. See product manual for bit descrip…
1.3.6.1.4.1.232.2.2.12.1.1.20ColumncpqSiFruCellTablePtrread-onlyoptionalIndex for the cell in cpqSeCellTable where this FRU is physically located.
1.3.6.1.4.1.232.2.2.12.1.1.21ColumncpqSiFruIOCTablePtrread-onlyoptionalIndex for the I/O Chassis in cpqSeIOCTablePtr where this FRU is physically located
1.3.6.1.4.1.232.2.2.12.1.1.22ColumncpqSiFruFileIdread-onlyoptionalThis represents the FRU file identifier
1.3.6.1.4.1.232.2.2.12.1.1.23ColumncpqSiFruScanRevread-onlyoptionalThis represents FRU scan revision
1.3.6.1.4.1.232.2.2.13NodecpqSiRackEnclosure
1.3.6.1.4.1.232.2.2.13.1TablecpqSiRackEnclosureMgrTablenot-accessiblemandatoryTable of possible rack and/or enclosure based systems.
1.3.6.1.4.1.232.2.2.13.1.1RowcpqSiRackEnclosureMgrEntrynot-accessiblemandatoryA entry for a rack and/or enclosure based system.
1.3.6.1.4.1.232.2.2.13.1.1.1ColumncpqSiRackEnclosureMgrIndexread-onlymandatoryA locally-unique index value.
1.3.6.1.4.1.232.2.2.13.1.1.2ColumncpqSiRackEnclosureMgrTyperead-onlymandatoryThis value specifies the type of enclosure management. other(1) When the type not be determined. noEnclosureManagement(2) The server is part of a rack/enclosur…
1.3.6.1.4.1.232.2.2.13.1.1.3ColumncpqSiRackEnclosureMgrIpAddrread-onlymandatoryThe IP address of the rack enclosure manager. The string will be empty if the enclosure does not report the information or it could not be determined.
1.3.6.1.4.1.232.2.2.13.1.1.4ColumncpqSiRackEnclosureMgrWebLinkread-onlymandatoryThe web link to the enclosure managers web based management information for the enclosure. The string will be empty if the enclosure does not report the inform…
1.3.6.1.4.1.232.2.2.13.1.1.5ColumncpqSiRackEnclosureMgrConditionread-onlymandatoryThe overall condition of the Enclosure. For more detailed status information, follow the cpqSiEnclosureMgrWebLink through the Web Management Agent interface. o…
1.3.6.1.4.1.232.2.2.13.1.1.6ColumncpqSiRackEnclosureMgrSerialNumberread-onlymandatoryThe serial number of the enclosure. The string will be empty if the enclosure does not report the information or it could not be determined.
1.3.6.1.4.1.232.2.2.13.1.1.7ColumncpqSiRackEnclosureMgrModelread-onlyoptionalThe model name of the enclosure. The string will be empty if it could not be determined.
1.3.6.1.4.1.232.2.2.13.1.1.8ColumncpqSiRackEnclosureMgrNameread-onlyoptionalThe name of the enclosure. This name logically groups together the Blade servers installed in the same enclosure and it is shared with the other servers in the…
1.3.6.1.4.1.232.2.2.13.1.1.9ColumncpqSiRackEnclosureMgrFwRevread-onlyoptionalThe Firmware revision of the Enclosure Manager/Onboard Administrator. The string will be empty if it could not be determined.
1.3.6.1.4.1.232.2.2.13.1.1.10ColumncpqSiRackEnclosureMgrProductIDread-onlyoptionalThe Enclosure product identifier. The string will be empty if it could not be determined.
1.3.6.1.4.1.232.2.2.13.1.1.11ColumncpqSiRackEnclosureMgrUUIDread-onlyoptionalThe Enclosure unique identifier. The string will be empty if it could not be determined.
1.3.6.1.4.1.232.2.2.13.1.1.12ColumncpqSiRackEnclosureMgrMatrixread-onlymandatoryValue 0 not configured in a BladeSystem Matrix environment. 1 configured in a BladeSystem Matrix environment.
1.3.6.1.4.1.232.2.2.13.1.1.13ColumncpqSiRackEnclosureMgrMatrixIDread-onlyoptionalValue BladeSystem Matrix vX.Y.Z Where X major version. Y minor version. Z update version. Is only valid if cpqSiRackEnclosureMgrMatrix value is a 1. By default…
1.3.6.1.4.1.232.2.2.14NodecpqSiServerBlade
1.3.6.1.4.1.232.2.2.14.1ScalarcpqSiServerBladeEnclosureBayNumberread-onlyoptionalThis value specifies the enclosure bay number occupied by the blade. In case of a blade occupying multiple bays, this will be the lowest enclosure bay number o…
1.3.6.1.4.1.232.2.2.14.2ScalarcpqSiServerBladeHeightread-onlyoptionalBlade height is the Blade length. unknown(1) This indicates it could not be determined. halfHeightBlade(2) This indicates a half-height server Blade. fullHeigh…
1.3.6.1.4.1.232.2.2.14.3ScalarcpqSiServerBladeWidthread-onlyoptionalWidth of the Blade in terms of Enclosure Bays. This pertain to the Blade side that connects to the enclosure backplane.
1.3.6.1.4.1.232.2.2.15NodecpqSiRack
1.3.6.1.4.1.232.2.2.15.1ScalarcpqSiRackNameread-onlyoptionalThe rack name. This name is used to logically group together enclosures in a rack and it is shared with other enclosures in the rack. The string will be empty …
1.3.6.1.4.1.232.2.2.15.2ScalarcpqSiRackUUIDread-onlyoptionalThe rack unique identifier. The string will be empty if it could be determined.
1.3.6.1.4.1.232.2.2.16NodecpqSiMP
1.3.6.1.4.1.232.2.2.16.1ScalarcpqSiMPHostNameread-onlyoptionalThe host name of the Management Processor. The string will be empty if it could not be determined.
1.3.6.1.4.1.232.2.2.16.2ScalarcpqSiMPHealthStatusread-onlyoptionalThe health status of the Management Processor.
1.3.6.1.4.1.232.2001NodecpqSiHoodRemovedSystem hood is removed. The hood status has been detected as removed. The system`s hood is not in a properly installed state. This situation may result in impr…
1.3.6.1.4.1.232.2002NodecpqSiMonitorConditionOKFault reporting features have returned to within their normal operating range for the monitor indicated by cpqSiMonitorIndex. The monitor`s condition has been …
1.3.6.1.4.1.232.2003NodecpqSiMonitorConditionDegradedA fault reporting feature has exceeded normal limits for the monitor indicated by the cpqSiMonitorIndex. The monitor`s condition is degraded due to the interna…
1.3.6.1.4.1.232.2004NodecpqSiMonitorConditionFailedA fault reporting feature has exceeded normal limits in the monitor indicated by the cpqSiMonitorIndex. The monitor`s condition has been set to failed due to a…
1.3.6.1.4.1.232.2005NodecpqSiCorrMemErrStatusDegradedCorrectable memory error count has exceeded the threshold for the memory module indicated by the `cpqSiMemErrorIndex` variable. The appropriate cpqSiMemModuleE…
1.3.6.1.4.1.232.2006NodecpqSiCorrMemErrStatusOkCorrectable memory error count is now below the threshold for the memory module indicated by the `cpqSiMemErrorIndex` variable. The appropriate cpqSiMemModuleE…
1.3.6.1.4.1.232.2007NodecpqSiMemConfigChangeA memory configuration change has occurred. CpqSiMemConfigChangeData will indicate which memory modules slots have changed. User Action: You may want to verify…
1.3.6.1.4.1.232.2008NodecpqSiHotPlugSlotBoardRemovedHot Plug Slot Board Removed. A Hot Plug Slot Board has been removed from the specified chassis and slot. User Action: None.
1.3.6.1.4.1.232.2009NodecpqSiHotPlugSlotBoardInsertedHot Plug Slot Board Inserted. A Hot Plug Slot Board has been inserted into the specified chassis and slot. User Action: None.
1.3.6.1.4.1.232.2010NodecpqSiHotPlugSlotPowerUpFailedHot Plug Slot Board Failed Power-Up. A Hot Plug Slot Board has failed to power-up in the specified chassis and slot. User Action: Insure the board and all cabl…
1.3.6.1.4.1.232.2011NodecpqSiSysBatteryFailureThe battery indicated by cpqSiSysBatteryIndex has failed and must be replaced. User Action: Contact your System Administrator or Authorized Reseller to order a…
1.3.6.1.4.1.232.2012NodecpqSiSysBatteryChargingDegradedSignificant battery degradation has occurred with battery indicated by cpqSiSysBatteryIndex. The battery can no longer be fully recharged. User Action: If usin…
1.3.6.1.4.1.232.2013NodecpqSiSysBatteryCalibrationErrorCalibration is needed with battery indicated by cpqSiSysBatteryIndex. The battery can not correctly indicate capacity. User Action: Run the Power Conservation …
1.3.6.1.4.1.232.2014NodecpqSiIntrusionInstalledSystem intrusion alert hardware is installed.
1.3.6.1.4.1.232.2015NodecpqSiIntrusionRemovedSystem intrusion alert hardware is removed.
1.3.6.1.4.1.232.2016NodecpqSiHoodReplacedSystem hood has been replaced.
1.3.6.1.4.1.232.2017NodecpqSiHoodRemovedOnPowerOffBIOS detected a system hood removal when server power was off.
1.3.6.1.4.1.232.2018NodecpqSiSysTelemetryThresholdAlertThe system telemetry metric value has either exceeded upper threshold or is below lower threshold.