CPQSTDEQ-MIB
233 objects
No module-level DESCRIPTION found.
Imported Objects
| OID | Name | Access | Status | Description |
|---|---|---|---|---|
| 1.3.6.1.4.1.232.1 | NodecpqStdEquipment | |||
| 1.3.6.1.4.1.232.1.1 | NodecpqSeMibRev | |||
| 1.3.6.1.4.1.232.1.1.1 | ScalarcpqSeMibRevMajor | read-only | mandatory | The Major Revision level of the MIB. A change in the major revision level represents a major change in the architecture of the MIB. A change in the major revis… |
| 1.3.6.1.4.1.232.1.1.2 | ScalarcpqSeMibRevMinor | read-only | mandatory | The Minor Revision level of the MIB. A change in the minor revision level may represent some minor additional support, no changes to any pre-existing informati… |
| 1.3.6.1.4.1.232.1.1.3 | ScalarcpqSeMibCondition | read-only | mandatory | The overall condition. This object represents the overall status of the server represented by this MIB. |
| 1.3.6.1.4.1.232.1.2 | NodecpqSeComponent | |||
| 1.3.6.1.4.1.232.1.2.1 | NodecpqSeInterface | |||
| 1.3.6.1.4.1.232.1.2.1.4 | NodecpqSeOsCommon | |||
| 1.3.6.1.4.1.232.1.2.1.4.1 | ScalarcpqSeOsCommonPollFreq | read-write | mandatory | The Insight Agent's polling frequency. The frequency, in seconds, at which the Insight Agent requests information from the device driver. A frequency of zero (… |
| 1.3.6.1.4.1.232.1.2.1.4.2 | TablecpqSeOsCommonModuleTable | not-accessible | deprecated | A table of software modules that provide an interface to the device this MIB describes. |
| 1.3.6.1.4.1.232.1.2.1.4.2.1 | RowcpqSeOsCommonModuleEntry | not-accessible | deprecated | A description of a software module that provides an interface to the device this MIB describes. |
| 1.3.6.1.4.1.232.1.2.1.4.2.1.1 | ColumncpqSeOsCommonModuleIndex | read-only | deprecated | A unique index for this module description. |
| 1.3.6.1.4.1.232.1.2.1.4.2.1.2 | ColumncpqSeOsCommonModuleName | read-only | deprecated | The module name. |
| 1.3.6.1.4.1.232.1.2.1.4.2.1.3 | ColumncpqSeOsCommonModuleVersion | read-only | deprecated | The module version in XX.YY format. Where XX is the major version number and YY is the minor version number. This field will be a null (size 0) string if the a… |
| 1.3.6.1.4.1.232.1.2.1.4.2.1.4 | ColumncpqSeOsCommonModuleDate | read-only | deprecated | The module date. field octets contents range ===== ====== ======= ===== 1 1-2 year 0..65536 2 3 month 1..12 3 4 day 1..31 4 5 hour 0..23 5 6 minute 0..59 6 7 s… |
| 1.3.6.1.4.1.232.1.2.1.4.2.1.5 | ColumncpqSeOsCommonModulePurpose | read-only | deprecated | The purpose of the module described in this entry. |
| 1.3.6.1.4.1.232.1.2.2 | NodecpqSeProcessor | |||
| 1.3.6.1.4.1.232.1.2.2.1 | TablecpqSeCpuTable | not-accessible | mandatory | A list of the CPUs (processors) in the system. The main processor (if such a concept is valid for this machine) should be the first entry in the table. |
| 1.3.6.1.4.1.232.1.2.2.1.1 | RowcpqSeCpuEntry | not-accessible | mandatory | A description of a CPU (processor) in the system. |
| 1.3.6.1.4.1.232.1.2.2.1.1.1 | ColumncpqSeCpuUnitIndex | read-only | mandatory | This is a number that uniquely specifies a processor unit. A processing unit may be a set of processing chips that are on the same board or for other reasons w… |
| 1.3.6.1.4.1.232.1.2.2.1.1.2 | ColumncpqSeCpuSlot | read-only | mandatory | This value represents this processor's slot. If the slot cannot be determined the value of zero (0) will be returned. |
| 1.3.6.1.4.1.232.1.2.2.1.1.3 | ColumncpqSeCpuName | read-only | mandatory | The name of this processor. For example: 80386 |
| 1.3.6.1.4.1.232.1.2.2.1.1.4 | ColumncpqSeCpuSpeed | read-only | mandatory | This is the internal speed in megahertz of this processor. Zero will be returned if this value is not available. |
| 1.3.6.1.4.1.232.1.2.2.1.1.5 | ColumncpqSeCpuStep | read-only | mandatory | This step of the processor. This will be zero (0) if the step cannot be determined. |
| 1.3.6.1.4.1.232.1.2.2.1.1.6 | ColumncpqSeCpuStatus | read-only | mandatory | The status of the processor. The following values are valid for CPU status: Unknown (1) The status of the CPU could not be determined. OK (2) The CPU is functi… |
| 1.3.6.1.4.1.232.1.2.2.1.1.7 | ColumncpqSeCpuExtSpeed | read-only | mandatory | This is the external frequency in megahertz of the processor bus. Zero will be returned if this value is not available. |
| 1.3.6.1.4.1.232.1.2.2.1.1.8 | ColumncpqSeCpuDesigner | read-only | mandatory | This attribute specifies the manufacturer which designs this CPU. |
| 1.3.6.1.4.1.232.1.2.2.1.1.9 | ColumncpqSeCpuSocketNumber | read-only | mandatory | The physical socket number of the CPU chip. This number helps to identify CPUs on processor boards that contain multiple CPU chips. In most cases the CPU Socke… |
| 1.3.6.1.4.1.232.1.2.2.1.1.10 | ColumncpqSeCpuThreshPassed | read-only | mandatory | CPU threshold passed (Exceeded). When this attribute is set to true, it identifies a pre-failure error condition. Processors like the Intel Pentium Pro have th… |
| 1.3.6.1.4.1.232.1.2.2.1.1.11 | ColumncpqSeCpuHwLocation | read-only | optional | A text description of the hardware location, on complex multi SBB hardware only, for the CPU. A NULL string indicates that the hardware location could not be d… |
| 1.3.6.1.4.1.232.1.2.2.2 | TablecpqSeFpuTable | not-accessible | mandatory | A list of the FPUs (floating point coprocessors) in the system. |
| 1.3.6.1.4.1.232.1.2.2.2.1 | RowcpqSeFpuEntry | not-accessible | mandatory | A description of a FPU in the system. The fpuUnitIndex of any entry in this table will equal the cpuUnitIndex of the corresponding CPU in the cpqSeCpu table. |
| 1.3.6.1.4.1.232.1.2.2.2.1.1 | ColumncpqSeFpuUnitIndex | read-only | mandatory | This is a number that uniquely specifies a processor unit. A processing unit may be a set of processing chips that are on the same board or for other reasons w… |
| 1.3.6.1.4.1.232.1.2.2.2.1.2 | ColumncpqSeFpuChipIndex | read-only | mandatory | This is a number that uniquely specifies the FPU chip. This field is used to distinguish between multiple FPUs that are part of the same processor unit. For ex… |
| 1.3.6.1.4.1.232.1.2.2.2.1.3 | ColumncpqSeFpuSlot | read-only | mandatory | This is the FPU's slot. If the slot cannot be determined the value of zero (0) will be returned. |
| 1.3.6.1.4.1.232.1.2.2.2.1.4 | ColumncpqSeFpuName | read-only | mandatory | This is the name of the FPU. For example: 80387 Weitek 3167 |
| 1.3.6.1.4.1.232.1.2.2.2.1.5 | ColumncpqSeFpuSpeed | read-only | mandatory | This is speed in megahertz of the FPU. Zero will be returned if this value is not available. |
| 1.3.6.1.4.1.232.1.2.2.2.1.6 | ColumncpqSeFpuType | read-only | mandatory | This value indicates if the FPU this entry is describing is embedded in the CPU or external to the CPU chip. |
| 1.3.6.1.4.1.232.1.2.2.2.1.7 | ColumncpqSeFpuHwLocation | read-only | optional | A text description of the hardware location, on complex multi SBB hardware only, for the FPU. A NULL string indicates that the hardware location could not be d… |
| 1.3.6.1.4.1.232.1.2.2.3 | TablecpqSeCpuCacheTable | not-accessible | mandatory | A list of the CPU caches in the system. |
| 1.3.6.1.4.1.232.1.2.2.3.1 | RowcpqSeCpuCacheEntry | not-accessible | mandatory | A description of a CPU Caches in the system. |
| 1.3.6.1.4.1.232.1.2.2.3.1.1 | ColumncpqSeCpuCacheUnitIndex | read-only | mandatory | This is a number that uniquely specifies a processor unit. A processing unit may be a set of processing chips that are on the same board or for other reasons w… |
| 1.3.6.1.4.1.232.1.2.2.3.1.2 | ColumncpqSeCpuCacheLevelIndex | read-only | mandatory | This is the processor cache level. The lower the processor cache level, the closer the cache is to the processor. |
| 1.3.6.1.4.1.232.1.2.2.3.1.3 | ColumncpqSeCpuCacheSize | read-only | mandatory | The size of the cache in kilobytes. |
| 1.3.6.1.4.1.232.1.2.2.3.1.4 | ColumncpqSeCpuCacheSpeed | read-only | mandatory | This is speed in cache memory in nanoseconds (ns). A value of zero (0) means that the cache speed is unknown or unobtainable. |
| 1.3.6.1.4.1.232.1.2.2.3.1.5 | ColumncpqSeCpuCacheStatus | read-only | mandatory | The status of the cache unit. If the cache is optional and not installed, unknown(1) will be returned. |
| 1.3.6.1.4.1.232.1.2.2.3.1.6 | ColumncpqSeCpuCacheWritePolicy | read-only | mandatory | Specifies write policy of this cache entry. |
| 1.3.6.1.4.1.232.1.2.2.3.1.7 | ColumncpqSeCpuCacheHwLocation | read-only | optional | A text description of the hardware location, on complex multi SBB hardware only, for the CPU cache. A NULL string indicates that the hardware location could no… |
| 1.3.6.1.4.1.232.1.2.3 | NodecpqSeMemory | |||
| 1.3.6.1.4.1.232.1.2.3.1 | ScalarcpqSeBaseMem | read-only | mandatory | The amount of base memory in kilobytes. A kilobyte is 1024 bytes. |
| 1.3.6.1.4.1.232.1.2.3.2 | ScalarcpqSeTotalMem | read-only | mandatory | The total amount of memory in kilobytes. A kilobyte is 1024 bytes. |
| 1.3.6.1.4.1.232.1.2.4 | NodecpqSeIsaCmos | |||
| 1.3.6.1.4.1.232.1.2.4.1 | ScalarcpqSeIsaCmosRaw | read-only | mandatory | The contents of the ISA CMOS. |
| 1.3.6.1.4.1.232.1.2.5 | NodecpqSeEisaNvram | |||
| 1.3.6.1.4.1.232.1.2.5.1 | TablecpqSeEisaSlotTable | not-accessible | mandatory | A list of EISA slot information entries. |
| 1.3.6.1.4.1.232.1.2.5.1.1 | RowcpqSeEisaSlotEntry | not-accessible | mandatory | A description of an EISA slot. |
| 1.3.6.1.4.1.232.1.2.5.1.1.1 | ColumncpqSeEisaSlotIndex | read-only | mandatory | The EISA slot number for this entry describes. |
| 1.3.6.1.4.1.232.1.2.5.1.1.2 | ColumncpqSeEisaSlotRaw | read-only | mandatory | The EISA slot data for the board in this slot. This octet string contains the following EISA slot information: The first octet will be zero (0) if this slot co… |
| 1.3.6.1.4.1.232.1.2.5.1.1.3 | ColumncpqSeEisaSlotBoardId | read-only | mandatory | A seven character board ID. The first three characters are the manufacturers ID followed by three character product ID followed by a one character revision lev… |
| 1.3.6.1.4.1.232.1.2.5.1.1.4 | ColumncpqSeEisaSlotBoardName | read-only | mandatory | The product name (or other suitable description) of this board. This field may be empty if no descriptive information is known about the board. |
| 1.3.6.1.4.1.232.1.2.5.1.1.5 | ColumncpqSeEisaSlotCfRev | read-only | mandatory | The revision level of the EISA configuration utility that was used to configure the system. This should be the same version information displayed by the EISA c… |
| 1.3.6.1.4.1.232.1.2.5.1.1.6 | ColumncpqSeEisaSlotType | read-only | mandatory | The type of slot described by this entry. |
| 1.3.6.1.4.1.232.1.2.5.2 | TablecpqSeEisaFunctTable | not-accessible | mandatory | A list EISA function information entries. |
| 1.3.6.1.4.1.232.1.2.5.2.1 | RowcpqSeEisaFunctEntry | not-accessible | mandatory | A description of an EISA function. |
| 1.3.6.1.4.1.232.1.2.5.2.1.1 | ColumncpqSeEisaFunctSlotIndex | read-only | mandatory | The EISA slot of the board that registered this function |
| 1.3.6.1.4.1.232.1.2.5.2.1.2 | ColumncpqSeEisaFunctIndex | read-only | mandatory | The number of the function this entry describes. |
| 1.3.6.1.4.1.232.1.2.5.2.1.3 | ColumncpqSeEisaFunctStatus | read-only | mandatory | The status of the function described by this entry. |
| 1.3.6.1.4.1.232.1.2.5.2.1.4 | ColumncpqSeEisaFunctType | read-only | mandatory | The type of the function. The type may be followed by one or more subtype description fields. Some currently defined types are: Type Meaning ============== ===… |
| 1.3.6.1.4.1.232.1.2.5.2.1.5 | ColumncpqSeEisaFunctCfgRev | read-only | mandatory | The revision of the EISA configuration .OVL file used to configure this board. |
| 1.3.6.1.4.1.232.1.2.5.2.1.6 | ColumncpqSeEisaFunctSels | read-only | mandatory | The selections that were chosen with the EISA CONFIGURATION UTILITY to create this function. |
| 1.3.6.1.4.1.232.1.2.5.2.1.7 | ColumncpqSeEisaFunctInfo | read-only | mandatory | The EISA function information block. This is a set of flags indicating the resources that are configured in this EISA function. Each bit has the following mean… |
| 1.3.6.1.4.1.232.1.2.5.3 | TablecpqSeEisaMemTable | not-accessible | mandatory | A list of EISA function memory configuration entries. |
| 1.3.6.1.4.1.232.1.2.5.3.1 | RowcpqSeEisaMemEntry | not-accessible | mandatory | A description of an EISA function memory configuration. |
| 1.3.6.1.4.1.232.1.2.5.3.1.1 | ColumncpqSeEisaMemSlotIndex | read-only | mandatory | The EISA slot number of the board that registered the memory configuration this entry describes. |
| 1.3.6.1.4.1.232.1.2.5.3.1.2 | ColumncpqSeEisaMemFunctIndex | read-only | mandatory | The function in which this memory configuration was registered. |
| 1.3.6.1.4.1.232.1.2.5.3.1.3 | ColumncpqSeEisaMemAllocIndex | read-only | mandatory | The index for this memory allocation entry in the EISA function block. |
| 1.3.6.1.4.1.232.1.2.5.3.1.4 | ColumncpqSeEisaMemStartAddr | read-only | mandatory | The starting address of the memory configuration. |
| 1.3.6.1.4.1.232.1.2.5.3.1.5 | ColumncpqSeEisaMemSize | read-only | mandatory | The size in bytes of the memory configuration. |
| 1.3.6.1.4.1.232.1.2.5.3.1.6 | ColumncpqSeEisaMemShare | read-only | mandatory | This value indicates if the memory is shareable. |
| 1.3.6.1.4.1.232.1.2.5.3.1.7 | ColumncpqSeEisaMemType | read-only | mandatory | The type of memory. |
| 1.3.6.1.4.1.232.1.2.5.3.1.8 | ColumncpqSeEisaMemCache | read-only | mandatory | This value indicates if the memory is cached. |
| 1.3.6.1.4.1.232.1.2.5.3.1.9 | ColumncpqSeEisaMemAccess | read-only | mandatory | The type of access permitted for this memory. |
| 1.3.6.1.4.1.232.1.2.5.3.1.10 | ColumncpqSeEisaMemDecode | read-only | mandatory | The memory decode size (the number of address lines supported). |
| 1.3.6.1.4.1.232.1.2.5.3.1.11 | ColumncpqSeEisaMemDataSize | read-only | mandatory | The data access size for the memory in bits. |
| 1.3.6.1.4.1.232.1.2.5.4 | TablecpqSeEisaIntTable | not-accessible | mandatory | A list of EISA function interrupt configuration entries. |
| 1.3.6.1.4.1.232.1.2.5.4.1 | RowcpqSeEisaIntEntry | not-accessible | mandatory | A description of an EISA function interrupt configuration. |
| 1.3.6.1.4.1.232.1.2.5.4.1.1 | ColumncpqSeEisaIntSlotIndex | read-only | mandatory | The EISA slot number of the board that registered the interrupt configuration this entry describes. |
| 1.3.6.1.4.1.232.1.2.5.4.1.2 | ColumncpqSeEisaIntFunctIndex | read-only | mandatory | The function in which this interrupt configuration was registered. |
| 1.3.6.1.4.1.232.1.2.5.4.1.3 | ColumncpqSeEisaIntAllocIndex | read-only | mandatory | The index for this interrupt allocation entry in the EISA function block. |
| 1.3.6.1.4.1.232.1.2.5.4.1.4 | ColumncpqSeEisaIntNum | read-only | mandatory | The interrupt described in this entry. |
| 1.3.6.1.4.1.232.1.2.5.4.1.5 | ColumncpqSeEisaIntShare | read-only | mandatory | This value indicates if the interrupt is shareable. |
| 1.3.6.1.4.1.232.1.2.5.4.1.6 | ColumncpqSeEisaIntTrigger | read-only | mandatory | This value indicates if the interrupt is edge or level triggered. |
| 1.3.6.1.4.1.232.1.2.5.5 | TablecpqSeEisaDmaTable | not-accessible | mandatory | A list of EISA function DMA configuration entries. |
| 1.3.6.1.4.1.232.1.2.5.5.1 | RowcpqSeEisaDmaEntry | not-accessible | mandatory | A description of an EISA function DMA configuration. |
| 1.3.6.1.4.1.232.1.2.5.5.1.1 | ColumncpqSeEisaDmaSlotIndex | read-only | mandatory | The EISA slot number of the board that registered the DMA configuration this entry describes. |
| 1.3.6.1.4.1.232.1.2.5.5.1.2 | ColumncpqSeEisaDmaFunctIndex | read-only | mandatory | The function in which this DMA configuration was registered. |
| 1.3.6.1.4.1.232.1.2.5.5.1.3 | ColumncpqSeEisaDmaAllocIndex | read-only | mandatory | The index for this DMA channel allocation entry in the EISA function block. |
| 1.3.6.1.4.1.232.1.2.5.5.1.4 | ColumncpqSeEisaDmaChannel | read-only | mandatory | The DMA channel described in this entry. |
| 1.3.6.1.4.1.232.1.2.5.5.1.5 | ColumncpqSeEisaDmaShare | read-only | mandatory | This value indicates if the DMA channel is shareable. |
| 1.3.6.1.4.1.232.1.2.5.5.1.6 | ColumncpqSeEisaDmaTiming | read-only | mandatory | This value indicates the timing (transfer rate) associated with this configuration of the DMA channel. |
| 1.3.6.1.4.1.232.1.2.5.5.1.7 | ColumncpqSeEisaDmaXfer | read-only | mandatory | This value indicates the transfer size in bits used over this DMA channel. |
| 1.3.6.1.4.1.232.1.2.5.5.1.8 | ColumncpqSeEisaDmaXferCount | read-only | mandatory | This value indicates the addessing scheme for the DMA channel. |
| 1.3.6.1.4.1.232.1.2.5.6 | TablecpqSeEisaPortTable | not-accessible | mandatory | A list of EISA function port I/O configuration entries. |
| 1.3.6.1.4.1.232.1.2.5.6.1 | RowcpqSeEisaPortEntry | not-accessible | mandatory | A description of an EISA function port I/O configuration. |
| 1.3.6.1.4.1.232.1.2.5.6.1.1 | ColumncpqSeEisaPortSlotIndex | read-only | mandatory | The EISA slot number of the board that registered the I/O port configuration this entry describes. |
| 1.3.6.1.4.1.232.1.2.5.6.1.2 | ColumncpqSeEisaPortFunctIndex | read-only | mandatory | The function in which this port I/O configuration was registered. |
| 1.3.6.1.4.1.232.1.2.5.6.1.3 | ColumncpqSeEisaPortAllocIndex | read-only | mandatory | The index for this I/O port range allocation entry in the EISA function block. |
| 1.3.6.1.4.1.232.1.2.5.6.1.4 | ColumncpqSeEisaPortAddr | read-only | mandatory | The I/O port address being described in this entry. |
| 1.3.6.1.4.1.232.1.2.5.6.1.5 | ColumncpqSeEisaPortShare | read-only | mandatory | This value indicates if the port is shareable. |
| 1.3.6.1.4.1.232.1.2.5.6.1.6 | ColumncpqSeEisaPortSize | read-only | mandatory | The number of sequential ports starting at the eisaPortAddrIndex that are be configured. |
| 1.3.6.1.4.1.232.1.2.5.7 | TablecpqSeEisaFreeFormTable | not-accessible | mandatory | A list of EISA function free form entries. |
| 1.3.6.1.4.1.232.1.2.5.7.1 | RowcpqSeEisaFreeFormEntry | not-accessible | mandatory | A description of an EISA function free form. |
| 1.3.6.1.4.1.232.1.2.5.7.1.1 | ColumncpqSeEisaFreeFormSlotIndex | read-only | mandatory | The EISA slot number of the board that registered the free form information this entry describes. |
| 1.3.6.1.4.1.232.1.2.5.7.1.2 | ColumncpqSeEisaFreeFormFunctIndex | read-only | mandatory | The function in which this free form was registered. |
| 1.3.6.1.4.1.232.1.2.5.7.1.3 | ColumncpqSeEisaFreeFormValue | read-only | mandatory | The free form value. |
| 1.3.6.1.4.1.232.1.2.5.8 | TablecpqSeEisaInitTable | not-accessible | mandatory | A list of EISA function port initialization entries. |
| 1.3.6.1.4.1.232.1.2.5.8.1 | RowcpqSeEisaInitEntry | not-accessible | mandatory | A description of an EISA function port initialization. |
| 1.3.6.1.4.1.232.1.2.5.8.1.1 | ColumncpqSeEisaInitSlotIndex | read-only | mandatory | The EISA slot number of the board that registered the port initialization this entry describes. |
| 1.3.6.1.4.1.232.1.2.5.8.1.2 | ColumncpqSeEisaInitFunctIndex | read-only | mandatory | The function in which this port initialization was registered. |
| 1.3.6.1.4.1.232.1.2.5.8.1.3 | ColumncpqSeEisaInitAllocIndex | read-only | mandatory | The index for this port initialization entry in the EISA function block. |
| 1.3.6.1.4.1.232.1.2.5.8.1.4 | ColumncpqSeEisaInitUseMask | read-only | mandatory | This indicates if a mask will be used when performing initialization. |
| 1.3.6.1.4.1.232.1.2.5.8.1.5 | ColumncpqSeEisaInitAccess | read-only | mandatory | This value indicates the number of bits this entry initializes. |
| 1.3.6.1.4.1.232.1.2.5.8.1.6 | ColumncpqSeEisaInitAddr | read-only | mandatory | This value indicates the port address this entry initializes. |
| 1.3.6.1.4.1.232.1.2.5.8.1.7 | ColumncpqSeEisaInitValue | read-only | mandatory | This indicates the value to which this port is initialized. |
| 1.3.6.1.4.1.232.1.2.5.8.1.8 | ColumncpqSeEisaInitMask | read-only | mandatory | This value indicates the mask to use when performing initialization. |
| 1.3.6.1.4.1.232.1.2.6 | NodecpqSeRom | |||
| 1.3.6.1.4.1.232.1.2.6.1 | ScalarcpqSeSysRomVer | read-only | mandatory | System ROM version information. |
| 1.3.6.1.4.1.232.1.2.6.2 | TablecpqSeOptRomTable | not-accessible | mandatory | A table of option ROM descriptions. |
| 1.3.6.1.4.1.232.1.2.6.2.1 | RowcpqSeOptRomEntry | not-accessible | mandatory | An option ROM description. |
| 1.3.6.1.4.1.232.1.2.6.2.1.1 | ColumncpqSeOptRomAddrIndex | read-only | mandatory | The starting address of the option ROM. This value indicates the number of bytes from the start of physical memory to the beginning of this option ROM. |
| 1.3.6.1.4.1.232.1.2.6.2.1.2 | ColumncpqSeOptRomSize | read-only | mandatory | The size in bytes of the option ROM. |
| 1.3.6.1.4.1.232.1.2.6.3 | ScalarcpqSeBiosRomDataRaw | read-only | mandatory | The BIOS ROM data area. This may be the current contents or a copy of the BIOS ROM data area from when the Insight Agent was initialized. |
| 1.3.6.1.4.1.232.1.2.6.4 | ScalarcpqSeRedundantSysRomVer | read-only | mandatory | System ROM version information for the redundant ROM image. This will be left blank if the system does not support a redundant ROM. |
| 1.3.6.1.4.1.232.1.2.7 | NodecpqSeKeyboard | |||
| 1.3.6.1.4.1.232.1.2.7.1 | ScalarcpqSeKeyboardDesc | read-only | mandatory | A description of the keyboard. |
| 1.3.6.1.4.1.232.1.2.8 | NodecpqSeVideo | |||
| 1.3.6.1.4.1.232.1.2.8.1 | ScalarcpqSeVideoDesc | read-only | mandatory | A description of the video system in the computer. This may include the manufacturer, board name, modes supported, etc.. |
| 1.3.6.1.4.1.232.1.2.9 | NodecpqSeSerialPort | |||
| 1.3.6.1.4.1.232.1.2.9.1 | TablecpqSeSerialPortTable | not-accessible | mandatory | A table of serial port descriptions. |
| 1.3.6.1.4.1.232.1.2.9.1.1 | RowcpqSeSerialPortEntry | not-accessible | mandatory | A description of a serial port. |
| 1.3.6.1.4.1.232.1.2.9.1.1.1 | ColumncpqSeSerialPortIndex | read-only | mandatory | An index that uniquely specifies this entry. |
| 1.3.6.1.4.1.232.1.2.9.1.1.2 | ColumncpqSeSerialPortAddr | read-only | mandatory | The I/O port address used by this serial port. |
| 1.3.6.1.4.1.232.1.2.9.1.1.3 | ColumncpqSeSerialPortDesc | read-only | mandatory | A text description of further information known about the serial port. This may be an empty string if no further information is known. |
| 1.3.6.1.4.1.232.1.2.9.1.1.4 | ColumncpqSeSerialPortHwLocation | read-only | optional | A text description of the hardware location, on complex multi SBB hardware only, for the serial port. A NULL string indicates that the hardware location could … |
| 1.3.6.1.4.1.232.1.2.10 | NodecpqSeParallelPort | |||
| 1.3.6.1.4.1.232.1.2.10.1 | TablecpqSeParallelPortTable | not-accessible | mandatory | A table of parallel port descriptions. |
| 1.3.6.1.4.1.232.1.2.10.1.1 | RowcpqSeParallelPortEntry | not-accessible | mandatory | A description of a parallel port. |
| 1.3.6.1.4.1.232.1.2.10.1.1.1 | ColumncpqSeParallelPortIndex | read-only | mandatory | An index that uniquely specifies this entry. |
| 1.3.6.1.4.1.232.1.2.10.1.1.2 | ColumncpqSeParallelPortAddr | read-only | mandatory | The I/O port address used by this parallel port. |
| 1.3.6.1.4.1.232.1.2.10.1.1.3 | ColumncpqSeParallelPortDesc | read-only | mandatory | A text description of further information known about the parallel port. This may be an empty string if no further information is known. |
| 1.3.6.1.4.1.232.1.2.10.1.1.4 | ColumncpqSeParrallelPortHwLocation | read-only | optional | A text description of the hardware location, on complex multi SBB hardware only, for the parrallel port. A NULL string indicates that the hardware location cou… |
| 1.3.6.1.4.1.232.1.2.11 | NodecpqSeFloppyDisk | |||
| 1.3.6.1.4.1.232.1.2.11.1 | TablecpqSeFloppyDiskTable | not-accessible | mandatory | A table of floppy drive descriptions. |
| 1.3.6.1.4.1.232.1.2.11.1.1 | RowcpqSeFloppyDiskEntry | not-accessible | mandatory | A floppy drive description. |
| 1.3.6.1.4.1.232.1.2.11.1.1.1 | ColumncpqSeFloppyDiskIndex | read-only | mandatory | An index that uniquely specifies this entry. If possible, this field will map directly to the drive letter (0 for A:, 1 for B:). |
| 1.3.6.1.4.1.232.1.2.11.1.1.2 | ColumncpqSeFloppyDiskType | read-only | mandatory | The type (capacity) of the floppy drive. The following values are valid: other (1) This floppy drive could not be identified. drive360k (2) This is a 360 kilob… |
| 1.3.6.1.4.1.232.1.2.11.1.1.3 | ColumncpqSeFloppyDiskHwLocation | read-only | optional | A text description of the hardware location, on complex multi SBB hardware only, for the floppy disk. A NULL string indicates that the hardware location could … |
| 1.3.6.1.4.1.232.1.2.12 | NodecpqSeFixedDisk | |||
| 1.3.6.1.4.1.232.1.2.12.1 | TablecpqSeFixedDiskTable | not-accessible | mandatory | A table of ST-506 interface accessible fixed disk descriptions. |
| 1.3.6.1.4.1.232.1.2.12.1.1 | RowcpqSeFixedDiskEntry | not-accessible | mandatory | A fixed disk description. |
| 1.3.6.1.4.1.232.1.2.12.1.1.1 | ColumncpqSeFixedDiskIndex | read-only | mandatory | An index that uniquely specifies this entry. Each possible index value indicates a specific drive as shown in the table below: fixedDiskIndex IDE/ESDI Controll… |
| 1.3.6.1.4.1.232.1.2.12.1.1.2 | ColumncpqSeFixedDiskType | read-only | mandatory | The drive type. |
| 1.3.6.1.4.1.232.1.2.12.1.1.3 | ColumncpqSeFixedDiskCyls | read-only | mandatory | The number of cylinders on the drive. |
| 1.3.6.1.4.1.232.1.2.12.1.1.4 | ColumncpqSeFixedDiskHeads | read-only | mandatory | The number of heads on the drive. |
| 1.3.6.1.4.1.232.1.2.12.1.1.5 | ColumncpqSeFixedDiskSectors | read-only | mandatory | The number of sectors per track on the drive. |
| 1.3.6.1.4.1.232.1.2.12.1.1.6 | ColumncpqSeFixedDiskCapacity | read-only | mandatory | The capacity of the drive in megabytes. |
| 1.3.6.1.4.1.232.1.2.12.1.1.7 | ColumncpqSeFixedDiskHwLocation | read-only | optional | A text description of the hardware location, on complex multi SBB hardware only, for the fixed disk. A NULL string indicates that the hardware location could n… |
| 1.3.6.1.4.1.232.1.2.13 | NodecpqSePci | |||
| 1.3.6.1.4.1.232.1.2.13.1 | TablecpqSePciSlotTable | not-accessible | mandatory | A list of PCI slot information entries. |
| 1.3.6.1.4.1.232.1.2.13.1.1 | RowcpqSePciSlotEntry | not-accessible | mandatory | A description of a PCI slot. |
| 1.3.6.1.4.1.232.1.2.13.1.1.1 | ColumncpqSePciSlotBusNumberIndex | read-only | mandatory | The PCI bus number for this device. |
| 1.3.6.1.4.1.232.1.2.13.1.1.2 | ColumncpqSePciSlotDeviceNumberIndex | read-only | mandatory | A number that uniquely identifies this device on its PCI bus. |
| 1.3.6.1.4.1.232.1.2.13.1.1.3 | ColumncpqSePciPhysSlot | read-only | mandatory | The physical PCI slot number of this device. Embedded devices will return 0 for this variable. |
| 1.3.6.1.4.1.232.1.2.13.1.1.4 | ColumncpqSePciSlotSubSystemID | read-only | mandatory | Uniquely identifies the board configured in this slot. A zero length ID indicates the Subsystem ID is not supported and the (Device ID/Vendor ID) should be use… |
| 1.3.6.1.4.1.232.1.2.13.1.1.5 | ColumncpqSePciSlotBoardName | read-only | mandatory | The product name (or other suitable description) of this PCI board. This field may be empty if no descriptive information is known about the board. |
| 1.3.6.1.4.1.232.1.2.13.1.1.6 | ColumncpqSePciSlotWidth | read-only | mandatory | The maximum data width supported by this PCI slot. |
| 1.3.6.1.4.1.232.1.2.13.1.1.7 | ColumncpqSePciSlotSpeed | read-only | deprecated | The maximum speed supported by this PCI slot. |
| 1.3.6.1.4.1.232.1.2.13.1.1.8 | ColumncpqSePciSlotExtendedInfo | read-only | mandatory | The PCI Extended Slot Information. This is a set of flags indicating extended features for the PCI slot. Each bit has the following meaning when it is set (1):… |
| 1.3.6.1.4.1.232.1.2.13.1.1.9 | ColumncpqSePciSlotType | read-only | mandatory | The type of PCI the slot. This indicates the capability of the slot, not the currently operating mode. |
| 1.3.6.1.4.1.232.1.2.13.1.1.10 | ColumncpqSePciSlotCurrentMode | read-only | mandatory | The current operating mode of PCI/PCI-X slot. This indicates the current operating mode of the device in the slot. If the slot is empty, this value would be un… |
| 1.3.6.1.4.1.232.1.2.13.1.1.11 | ColumncpqSePciMaxSlotSpeed | read-only | mandatory | The maximum speed in megahertz supported by this PCI slot. If the slot also supports PCI-X, this value indicates the maximum speed of the slot when a non-PCI-X… |
| 1.3.6.1.4.1.232.1.2.13.1.1.12 | ColumncpqSePciXMaxSlotSpeed | read-only | mandatory | The maximum speed in megahertz supported by this PCI-X slot. An entry of 0 indicates the speed is unknown. An entry of -1 indicates the slot does not support P… |
| 1.3.6.1.4.1.232.1.2.13.1.1.13 | ColumncpqSePciCurrentSlotSpeed | read-only | mandatory | The current speed in megahertz of the adapter in this PCI or PCI-X slot. An entry of 0 indicates the speed is could not be determined or the slot is empty. |
| 1.3.6.1.4.1.232.1.2.13.1.1.14 | ColumncpqSePciHwLocation | read-only | optional | A text description of the hardware location, on complex multi SBB hardware only, for the Peripheral Component Interconnect (PCI) bus. A NULL string indicates t… |
| 1.3.6.1.4.1.232.1.2.13.2 | TablecpqSePciFunctTable | not-accessible | mandatory | A list of PCI function information entries. |
| 1.3.6.1.4.1.232.1.2.13.2.1 | RowcpqSePciFunctEntry | not-accessible | mandatory | A description of the functions in each PCI slot. |
| 1.3.6.1.4.1.232.1.2.13.2.1.1 | ColumncpqSePciFunctBusNumberIndex | read-only | mandatory | The PCI bus number for this device function. |
| 1.3.6.1.4.1.232.1.2.13.2.1.2 | ColumncpqSePciFunctDeviceNumberIndex | read-only | mandatory | The device index for this function. |
| 1.3.6.1.4.1.232.1.2.13.2.1.3 | ColumncpqSePciFunctIndex | read-only | mandatory | The unique index that specifies this function. |
| 1.3.6.1.4.1.232.1.2.13.2.1.4 | ColumncpqSePciFunctClassCode | read-only | mandatory | The class code register as defined in the PCI Local Bus Specification in the following format: Octet Register 1 Programming Interface 2 Sub-class code 3 Base c… |
| 1.3.6.1.4.1.232.1.2.13.2.1.5 | ColumncpqSePciFunctClassDescription | read-only | mandatory | A text string which describes the PCI Base Class and Sub Class to which this device belongs. This field may empty if no descriptive information is known about … |
| 1.3.6.1.4.1.232.1.2.13.2.1.6 | ColumncpqSePciFunctDeviceID | read-only | mandatory | This variable identifies this particular device. This identifier is allocated by the component manufacturer. |
| 1.3.6.1.4.1.232.1.2.13.2.1.7 | ColumncpqSePciFunctVendorID | read-only | mandatory | This variable identifies the component manufacturer. Valid identifiers are assigned by the PCI SIG. |
| 1.3.6.1.4.1.232.1.2.13.2.1.8 | ColumncpqSePciFunctRevID | read-only | mandatory | This variable is a vendor defined extension to the device ID and specifies a device specific revision identifier. |
| 1.3.6.1.4.1.232.1.2.13.2.1.9 | ColumncpqSePciFunctIntLine | read-only | mandatory | This variable specifies which input of the system interrupt controller(s) the device's interrupt pin is connected to. A value of 0ffh means unknown or no conne… |
| 1.3.6.1.4.1.232.1.2.13.2.1.10 | ColumncpqSePciFunctDevStatus | read-only | mandatory | The status of the device described by this function. Some PCI devices, such as embedded devices, have the potential of being present but disabled. |
| 1.3.6.1.4.1.232.1.2.13.2.1.11 | ColumncpqSePciFunctHwLocation | read-only | optional | A text description of the hardware location, on complex multi SBB hardware only, for the Peripheral Component Interconnect (PCI) bus. A NULL string indicates t… |
| 1.3.6.1.4.1.232.1.2.13.3 | TablecpqSePciMemoryTable | not-accessible | mandatory | A list of PCI base memory entries |
| 1.3.6.1.4.1.232.1.2.13.3.1 | RowcpqSePciMemoryEntry | not-accessible | mandatory | A description of the base memory usage in each function |
| 1.3.6.1.4.1.232.1.2.13.3.1.1 | ColumncpqSePciMemoryBusNumberIndex | read-only | mandatory | The PCI bus number for this memory entry. |
| 1.3.6.1.4.1.232.1.2.13.3.1.2 | ColumncpqSePciMemoryDeviceNumberIndex | read-only | mandatory | The device index for this memory entry |
| 1.3.6.1.4.1.232.1.2.13.3.1.3 | ColumncpqSePciMemoryFunctionIndex | read-only | mandatory | The unique index that specifies the function associated with this memory entry. |
| 1.3.6.1.4.1.232.1.2.13.3.1.4 | ColumncpqSePciMemoryIndex | read-only | mandatory | The unique index that specifies this memory entry. |
| 1.3.6.1.4.1.232.1.2.13.3.1.5 | ColumncpqSePciMemoryBaseAddr | read-only | mandatory | Base address of this memory usage entry. |
| 1.3.6.1.4.1.232.1.2.13.3.1.6 | ColumncpqSePciMemoryType | read-only | mandatory | The type of memory this entry describes. This variable is used to determine if this memory entry maps into memory, expansion rom or I/O space. |
| 1.3.6.1.4.1.232.1.2.13.3.1.7 | ColumncpqSePciMemorySize | read-only | mandatory | This variable specifies how much address space this function requires. A value of 0 will be returned if the agent cannot obtain this information. |
| 1.3.6.1.4.1.232.1.2.13.3.1.8 | ColumncpqSePciMemoryHwLocation | read-only | optional | A text description of the hardware location, on complex multi SBB hardware only, for the Peripheral Component Interconnect (PCI) bus. A NULL string indicates t… |
| 1.3.6.1.4.1.232.1.2.14 | NodecpqSePCCard | |||
| 1.3.6.1.4.1.232.1.2.14.1 | TablecpqSePCCardSlotTable | not-accessible | mandatory | A list of PC Card slot information entries. |
| 1.3.6.1.4.1.232.1.2.14.1.1 | RowcpqSePCCardSlotEntry | not-accessible | mandatory | A PC Card slot description table entry. A table entry is defined for each PC Card Slot in the current system configuration. |
| 1.3.6.1.4.1.232.1.2.14.1.1.1 | ColumncpqSePCCardSlotIndex | read-only | mandatory | Defines the logical PC Card slot number for this PC Card Slot. In addition, the slot number serves as the index into the PC Card data table. Typical index rang… |
| 1.3.6.1.4.1.232.1.2.14.1.1.2 | ColumncpqSePCCardCondition | read-only | mandatory | Defines the overall condition of the PC Card. The supported values are defined as follows: unknown(1) The current condition is unknown for the PC Card or PC Ca… |
| 1.3.6.1.4.1.232.1.2.14.1.1.3 | ColumncpqSePCCardPhysLocation | read-only | mandatory | Defines the user level PC Card Slot location description. Text strings supported are: - System Unit Top Slot, - System Unit Bottom Slot, - Docking Station Top … |
| 1.3.6.1.4.1.232.1.2.14.1.1.4 | ColumncpqSePCCardSlotType | read-only | mandatory | Defines the PC Card Slot capabilities. This is a bit mapped value defined by DMI Mobile Supplement for the System Slots Group, Slot Type. Bits of interest for … |
| 1.3.6.1.4.1.232.1.2.14.1.1.5 | ColumncpqSePCCardSlotWidth | read-only | mandatory | Defines the maximum bus width for this PC Card Slot. The supported values are defined as follows: Other (1) Value is not in defined list. Unknown (2) Actual va… |
| 1.3.6.1.4.1.232.1.2.14.1.1.6 | ColumncpqSePCCardSlotThermalCapacity | read-only | mandatory | Defines the maximum thermal dissipation capacity (milliwatts) for this PC Card Slot. A value of zero indicates the thermal capacity is unknown. A non-zero valu… |
| 1.3.6.1.4.1.232.1.2.14.1.1.7 | ColumncpqSePCCardSlotThermalSensor | read-only | mandatory | Defines the Thermal Sensor ID that monitors this PC Card Slot. A value of zero indicates that a sensor is not present or unknown for this slot. A non-zero valu… |
| 1.3.6.1.4.1.232.1.2.14.1.1.8 | ColumncpqSePCCardSlotPowerState | read-only | mandatory | Defines the current power state (On/Off) for this PC Card Slot. The supported values are defined as follows: unknown (1) Current power state is unknown. on (2)… |
| 1.3.6.1.4.1.232.1.2.14.1.1.9 | ColumncpqSePCCardStatus | read-only | mandatory | Defines the operating status for the card in this PC Card Slot. The supported values are defined as follows: unknown (1) The current status is not known for th… |
| 1.3.6.1.4.1.232.1.2.14.1.1.10 | ColumncpqSePCCardDeviceInfo | read-only | mandatory | Defines the PC Card Manufacturer / Device information for the card in this PC Card Slot. The returned string data is read from the PC Card's onboard Card Infor… |
| 1.3.6.1.4.1.232.1.2.14.1.1.11 | ColumncpqSePCCardProductInfo | read-only | mandatory | Defines the PC Card Model / Part Number information for the card in this PC Card Slot. The returned string data is read from the PC Card's onboard Card Informa… |
| 1.3.6.1.4.1.232.1.2.14.1.1.12 | ColumncpqSePCCardSerialNumber | read-only | mandatory | Defines the PC Card Serial Number information for the card in this PC Card Slot. The returned string data is read from the PC Card's onboard Card Information S… |
| 1.3.6.1.4.1.232.1.2.14.1.1.13 | ColumncpqSePCCardAssetTag | read-only | mandatory | Defines the PC Card Asset Tag information for the card in this PC Card Slot. The returned string data is read from the PC Card's onboard Card Information Struc… |
| 1.3.6.1.4.1.232.1.2.15 | NodecpqSeUSBPort | |||
| 1.3.6.1.4.1.232.1.2.15.1 | TablecpqSeUSBPortTable | not-accessible | mandatory | A table of USB port descriptions. |
| 1.3.6.1.4.1.232.1.2.15.1.1 | RowcpqSeUSBPortEntry | not-accessible | mandatory | A description of a USB port. |
| 1.3.6.1.4.1.232.1.2.15.1.1.1 | ColumncpqSeUSBPortIndex | read-only | mandatory | An index that uniquely specifies this entry. |
| 1.3.6.1.4.1.232.1.2.15.1.1.2 | ColumncpqSeUSBPortType | read-only | mandatory | The port type. The supported values are defined as follows: other (1) USB port data is not available. usbPort (2) The port is a USB Port. |
| 1.3.6.1.4.1.232.1.2.15.1.1.3 | ColumncpqSeUSBPortHwLocation | read-only | optional | A text description of the hardware location, on complex multi SBB hardware only, for the USB port. A NULL string indicates that the hardware location could not… |
| 1.3.6.1.4.1.232.1001 | NodecpqSeCpuThresholdPassed | This trap is sent when an internal CPU error threshold has been passed on a particular CPU causing it to go degraded. This trap will be sent when cpqSeCpuThres… | ||
| 1.3.6.1.4.1.232.1002 | NodecpqSePCCardThermalDegraded | This trap is sent when the PC Card Slot Thermal Sensor threshold has been exceeded for safe operations thereby causing degraded operations. This trap will be s… | ||
| 1.3.6.1.4.1.232.1003 | NodecpqSePCCardThermalFailure | This trap is sent when the PC Card Slot Thermal Sensor threshold has been exceeded for degraded operations thereby causing failed operations. This trap will be… | ||
| 1.3.6.1.4.1.232.1004 | NodecpqSePCCardThermalSafe | This trap is sent when the PC Card Slot Thermal Sensor threshold has been crossed which restored the thermal status to normal operations. This trap will be sen… |