OIDNameAccessStatusDescription
1.3.6.1.4.1.232.8NodecpqSsStorageSys
1.3.6.1.4.1.232.8.1NodecpqSsFanStatusChangeStorage System fan status change. The agent has detected a change in the Fan Status of a storage system. The variable cpqSsBoxFanStatus indicates the current f…
1.3.6.1.4.1.232.8.1NodecpqSsMibRev
1.3.6.1.4.1.232.8.1.1ScalarcpqSsMibRevMajorread-onlymandatoryThe Major Revision level. A change in the major revision level represents a major change in the architecture of the MIB. A change in the major revision level m…
1.3.6.1.4.1.232.8.1.2ScalarcpqSsMibRevMinorread-onlymandatoryThe Minor Revision level. A change in the minor revision level may represent some minor additional support; no changes to any pre-existing information has occu…
1.3.6.1.4.1.232.8.1.3ScalarcpqSsMibConditionread-onlymandatoryThe overall condition (status) of the system represented by this MIB.
1.3.6.1.4.1.232.8.2NodecpqSsDrvBox
1.3.6.1.4.1.232.8.2.1TablecpqSsDrvBoxTablenot-accessiblemandatoryDrive Box Table.
1.3.6.1.4.1.232.8.2.1.1RowcpqSsDrvBoxEntrynot-accessiblemandatoryDrive Box Entry.
1.3.6.1.4.1.232.8.2.1.1.1ColumncpqSsBoxCntlrIndexread-onlymandatoryDrive Box Controller Index. The controller index indicates to which adapter card instance this table entry belongs.
1.3.6.1.4.1.232.8.2.1.1.2ColumncpqSsBoxBusIndexread-onlymandatoryDrive Box Bus Index. The bus index indicates to which bus instance on an adapter card this table entry belongs.
1.3.6.1.4.1.232.8.2.1.1.3ColumncpqSsBoxTyperead-onlydeprecatedDrive Box Type. This is the type of drive box. The following types are defined: other(1) The agent does not recognize this drive storage system. proLiant(2) Th…
1.3.6.1.4.1.232.8.2.1.1.4ColumncpqSsBoxModelread-onlymandatoryDrive Box Model. This is a description of the drive box`s model. This can be used for identification purposes.
1.3.6.1.4.1.232.8.2.1.1.5ColumncpqSsBoxFWRevread-onlymandatoryDrive Box Firmware Revision. This is the revision level of the drive box. This can be used for identification purposes.
1.3.6.1.4.1.232.8.2.1.1.6ColumncpqSsBoxVendorread-onlymandatoryDrive Box Vendor This is the drive box`s vendor name. This can be used for identification purposes.
1.3.6.1.4.1.232.8.2.1.1.7ColumncpqSsBoxFanStatusread-onlymandatoryDrive Box Fan Status. This is the current status of the fans in the drive box. This value will be one of the following: other(1) Fan monitoring is not supporte…
1.3.6.1.4.1.232.8.2.1.1.8ColumncpqSsBoxConditionread-onlymandatorySCSI Drive Box Condition. This is the overall condition of the drive box. The following values are defined: other(1) The agent does not recognize the status. Y…
1.3.6.1.4.1.232.8.2.1.1.9ColumncpqSsBoxTempStatusread-onlymandatoryThe temperature of the drive system. This value will be one of the following: other(1) Temperature monitoring is not supported by this system or it is not supp…
1.3.6.1.4.1.232.8.2.1.1.10ColumncpqSsBoxSidePanelStatusread-onlymandatoryDrive Box Side Panel Status. This value will be one of the following: other(1) The agent does not recognize the status. You may need to upgrade your software. …
1.3.6.1.4.1.232.8.2.1.1.11ColumncpqSsBoxFltTolPwrSupplyStatusread-onlymandatoryThis value specifies the overall status of the fault tolerant power supply sub-system in a drive box. This value will be one of the following: other(1) The pow…
1.3.6.1.4.1.232.8.2.1.1.12ColumncpqSsBoxBackPlaneVersionread-onlymandatoryDrive Box Back Plane Version. This is the version of the drive box back plane. The following types are defined: other(1) The agent does not recognize this driv…
1.3.6.1.4.1.232.8.2.1.1.13ColumncpqSsBoxTotalBaysread-onlymandatoryDrive Box Total Bays. This is the total number of bays in this storage system. If the value cannot be determined or does not apply, -1 is returned.
1.3.6.1.4.1.232.8.2.1.1.14ColumncpqSsBoxPlacementread-onlymandatoryDrive Box Placement. The following values are defined: other(1) The agent is unable to determine if this storage system is located internal or external to the …
1.3.6.1.4.1.232.8.2.1.1.15ColumncpqSsBoxDuplexOptionread-onlymandatoryDrive Box Duplex Option. The following values are defined: other(1) The agent is unable to determine if this storage system is duplexed. notDuplexed(2) This st…
1.3.6.1.4.1.232.8.2.1.1.16ColumncpqSsBoxBoardRevisionread-onlymandatoryDrive Box Board Revision. This is the board revision of this storage system backplane.
1.3.6.1.4.1.232.8.2.1.1.17ColumncpqSsBoxSerialNumberread-onlymandatoryDrive Box Serial Number. This is the drive box`s serial number which is normally display on the front panel. This can be used for identification purposes. If t…
1.3.6.1.4.1.232.8.2.1.1.18ColumncpqSsBoxCntlrHwLocationread-onlymandatoryA text description of the hardware location of the controller to which this box is attached. A NULL string indicates that the hardware location could not be de…
1.3.6.1.4.1.232.8.2.1.1.19ColumncpqSsBoxBackplaneSpeedread-onlymandatoryDrive Box Backplane Speed. The following values are defined: other(1) The agent is unable to determine the backplane speed for this storage system. ultra3(2) T…
1.3.6.1.4.1.232.8.2.1.1.20ColumncpqSsBoxConnectionTyperead-onlymandatoryDrive Box Connection Type. The following values are defined: other(1) The agent is unable to determine the type of connection to this storage system. scsiAttac…
1.3.6.1.4.1.232.8.2.1.1.21ColumncpqSsBoxHostConnectorread-onlymandatoryDrive Box Host Connector. This is the host connector to which the drive box is attached. If the host connector cannot be determined, the agent will return a NU…
1.3.6.1.4.1.232.8.2.1.1.22ColumncpqSsBoxBoxOnConnectorread-onlymandatoryDrive Box, Box on Connector. The box on connector indicates which box instance this table entry belongs. The instances start at one and increment for each box …
1.3.6.1.4.1.232.8.2.1.1.23ColumncpqSsBoxLocationStringread-onlymandatoryDrive Box Location String. This string describes the location of the drive box in relation to the controller to which it is attached. If the location string ca…
1.3.6.1.4.1.232.8.2.1.1.24ColumncpqSsBoxInitiatorSasAddressread-onlymandatoryDrive Box Initiator SAS Address String. This string describes the SAS address of the initiator connected to the drive box. If the drive box initiator SAS addre…
1.3.6.1.4.1.232.8.2.1.1.25ColumncpqSsBoxTargetSasAddressread-onlymandatoryDrive Box Target SAS Address String. This string describes the SAS address of the target (i.e. the drive box itself). If the drive box target SAS address strin…
1.3.6.1.4.1.232.8.2.1.1.26ColumncpqSsBoxLocalManageIpAddressread-onlymandatoryDrive Box Local Management IP Address String. This string reports the management IP address for the storage box primary controller. If the drive box local mana…
1.3.6.1.4.1.232.8.2.1.1.27ColumncpqSsBoxPartnerManageIpAddressread-onlymandatoryDrive Box Partner Management IP Address String. This string reports the management IP address for the storage box partner controller. If the drive box partner …
1.3.6.1.4.1.232.8.2.1.1.28ColumncpqSsBoxConnectionStatusread-onlymandatoryDrive Box Connection Status. The following values are defined: other(1) The agent is unable to determine the storage system`s connection status. notSupported(2…
1.3.6.1.4.1.232.8.2.1.1.29ColumncpqSsBoxTargetBasedManagementread-onlymandatoryDrive Box Target Based Management. The following values are defined: other(1) The agent is unable to determine if this storage system supports target based man…
1.3.6.1.4.1.232.8.2.1.1.30ColumncpqSsBoxGSIStatusread-onlymandatoryDrive Box GSI Status. This is the status based on the stateof the Global Service Indicator. The following values are defined: other(1) The agent does not recog…
1.3.6.1.4.1.232.8.2.1.1.31ColumncpqSsBoxGSIMessagesread-onlymandatoryDrive Box GSI Messages. This string will contain any error message from the drive box describing why the Global Service Indicator is set. Please refer to User …
1.3.6.1.4.1.232.8.2.2NodecpqSsBoxExtended
1.3.6.1.4.1.232.8.2.2.1TablecpqSsChassisTablenot-accessiblemandatoryStorage System Chassis Table.
1.3.6.1.4.1.232.8.2.2.1.1RowcpqSsChassisEntrynot-accessiblemandatoryStorage System Chassis Entry.
1.3.6.1.4.1.232.8.2.2.1.1.1ColumncpqSsChassisIndexread-onlymandatoryStorage System Chassis Index. The chassis index uniquely identifies a storage system chassis.
1.3.6.1.4.1.232.8.2.2.1.1.2ColumncpqSsChassisConnectionTyperead-onlymandatoryStorage System Chassis Connection Type. The following values are defined: other(1) The agent is unable to determine the type of connection to this chassis. fib…
1.3.6.1.4.1.232.8.2.2.1.1.3ColumncpqSsChassisSerialNumberread-onlymandatoryStorage System Chassis Serial Number. This is the storage system chassis`s serial number which is normally displayed on the front panel. This can be used for i…
1.3.6.1.4.1.232.8.2.2.1.1.4ColumncpqSsChassisNameread-onlymandatoryStorage System Chassis Name. This is a user defined name for this storage system chassis.
1.3.6.1.4.1.232.8.2.2.1.1.5ColumncpqSsChassisSystemBoardSerNumread-onlymandatoryStorage System Chassis System Controller Board Serial Number. This is the system controller board`s serial number. This can be used for identification purposes.
1.3.6.1.4.1.232.8.2.2.1.1.6ColumncpqSsChassisSystemBoardRevread-onlymandatoryStorage System Chassis System Controller Board Revision. This is the system controller board revision.
1.3.6.1.4.1.232.8.2.2.1.1.7ColumncpqSsChassisPowerBoardSerNumread-onlymandatoryStorage System Chassis Power Backplane Board Serial Number. This is the power backplane board`s serial number. This can be used for identification purposes.
1.3.6.1.4.1.232.8.2.2.1.1.8ColumncpqSsChassisPowerBoardRevread-onlymandatoryStorage System Chassis Power Backplane Board Revision. This is the power backplane board revision.
1.3.6.1.4.1.232.8.2.2.1.1.9ColumncpqSsChassisScsiBoardSerNumread-onlymandatoryStorage System Chassis SCSI Drive Backplane Board Serial Number. This is the SCSI drive backplane board`s serial number. This can be used for identification pu…
1.3.6.1.4.1.232.8.2.2.1.1.10ColumncpqSsChassisScsiBoardRevread-onlymandatoryStorage System Chassis SCSI Drive Backplane Board Revision. This is the SCSI drive backplane board revision.
1.3.6.1.4.1.232.8.2.2.1.1.11ColumncpqSsChassisOverallConditionread-onlymandatoryStorage System Chassis Overall Condition. This is the condition of the storage system chassis and all of its components. The following values are defined: othe…
1.3.6.1.4.1.232.8.2.2.1.1.12ColumncpqSsChassisPowerSupplyConditionread-onlymandatoryStorage System Power Supply Condition. This is the aggregate condition of all power supplies in the storage system chassis. The following values are defined: o…
1.3.6.1.4.1.232.8.2.2.1.1.13ColumncpqSsChassisFanConditionread-onlymandatoryStorage System Fan Condition. This is the aggregate condition of all fan modules in the storage system chassis. The following values are defined: other(1) The …
1.3.6.1.4.1.232.8.2.2.1.1.14ColumncpqSsChassisTemperatureConditionread-onlymandatoryStorage System Temperature Condition. This is the aggregate condition of all the temperatur sensors in the storage system chassis. The following values are def…
1.3.6.1.4.1.232.8.2.2.1.1.15ColumncpqSsChassisFcaCntlrConditionread-onlymandatoryStorage System Fibre Channel Array Controller Condition. This is the aggregate condition of all Fibre Channel Array controllers in the storage system chassis. …
1.3.6.1.4.1.232.8.2.2.1.1.16ColumncpqSsChassisFcaLogicalDriveConditionread-onlymandatoryStorage System Fibre Channel Array Logical Drive Condition. This is the aggregate condition of all Fibre Channel Array Logical Drives in this storage system ch…
1.3.6.1.4.1.232.8.2.2.1.1.17ColumncpqSsChassisFcaPhysDrvConditionread-onlymandatoryStorage System Fibre Channel Array Physical Drive Condition. This is the aggregate condition of all Fibre Channel Array Physical Drives in this storage system …
1.3.6.1.4.1.232.8.2.2.1.1.18ColumncpqSsChassisTimeread-onlymandatoryStorage System Chassis Time. This is the storage system chassis`s time in tenths of seconds. If the chassis time is not supported, the agent will return 0.
1.3.6.1.4.1.232.8.2.2.1.1.19ColumncpqSsChassisModelread-onlymandatoryStorage System Chassis Model. The following values are defined: other(1) The agent is unable to determine the model of this chassis. ra4x00(2) Compaq StorageWo…
1.3.6.1.4.1.232.8.2.2.1.1.20ColumncpqSsChassisBackplaneConditionread-onlymandatoryStorage System Backplane Condition. This is the aggregate condition of all the backplanes for the storage system chassis. The following values are defined: oth…
1.3.6.1.4.1.232.8.2.2.1.1.21ColumncpqSsChassisFcaTapeDrvConditionread-onlymandatoryStorage System Array Tape Drive Condition. This is the aggregate condition of all tape drives in this storage system chassis. The following values are defined:…
1.3.6.1.4.1.232.8.2.2.1.1.22ColumncpqSsChassisRsoStatusread-onlymandatoryStorage System Chassis Recovery Server Option Status. The following values are defined: other(1) The recovery server option status cannot be determined for thi…
1.3.6.1.4.1.232.8.2.2.1.1.23ColumncpqSsChassisRsoConditionread-onlymandatoryStorage System Chassis Recovery Server Option Condition. This is the condition of the recovery server option. The following values are defined: other(1) The ag…
1.3.6.1.4.1.232.8.2.2.1.1.24ColumncpqSsChassisScsiIoModuleTyperead-onlymandatoryStorage System Chassis SCSI I/O Module Type. The following values are defined: other(1) The agent does not recognize SCSI I/O module type. You may need to upgr…
1.3.6.1.4.1.232.8.2.2.1.1.25ColumncpqSsChassisPreferredPathModeread-onlymandatoryArray Controller Preferred Path Mode. This is the storage system active/active preferred path mode. The following values are valid: other (1) Indicates that th…
1.3.6.1.4.1.232.8.2.2.1.1.26ColumncpqSsChassisProductIdread-onlymandatoryStorage System Chassis Product Identifier. This is the storage system chassis's product identifier. This can be used for identification purposes. If the produc…
1.3.6.1.4.1.232.8.2.2.2TablecpqSsIoSlotTablenot-accessiblemandatoryStorage System I/O Slot Table.
1.3.6.1.4.1.232.8.2.2.2.1RowcpqSsIoSlotEntrynot-accessiblemandatoryStorage System I/O Slot Entry.
1.3.6.1.4.1.232.8.2.2.2.1.1ColumncpqSsIoSlotChassisIndexread-onlymandatoryStorage System I/O Slot Chassis Index. The chassis index uniquely identifies a storage system chassis.
1.3.6.1.4.1.232.8.2.2.2.1.2ColumncpqSsIoSlotIndexread-onlymandatoryStorage System I/O Slot Index. This index uniquely identifies a storage system I/O Slot.
1.3.6.1.4.1.232.8.2.2.2.1.3ColumncpqSsIoSlotControllerTyperead-onlymandatoryStorage System I/O Slot Controller Type. The following values are defined: other(1) The agent is unable to determine if anything is installed in this storage s…
1.3.6.1.4.1.232.8.2.2.3TablecpqSsPowerSupplyTablenot-accessiblemandatoryStorage System Power Supply Table.
1.3.6.1.4.1.232.8.2.2.3.1RowcpqSsPowerSupplyEntrynot-accessiblemandatoryStorage System Power Supply Entry.
1.3.6.1.4.1.232.8.2.2.3.1.1ColumncpqSsPowerSupplyChassisIndexread-onlymandatoryStorage System Power Supply Chassis Index. The chassis index uniquely identifies a storage system chassis.
1.3.6.1.4.1.232.8.2.2.3.1.2ColumncpqSsPowerSupplyIndexread-onlymandatoryStorage System Power Supply Bay. This index uniquely identifies a power supply bay.
1.3.6.1.4.1.232.8.2.2.3.1.3ColumncpqSsPowerSupplyBayread-onlymandatoryStorage System Power Supply Bay. The following values are defined: other(1) The agent does not recognize the bay. You may need to upgrade your software. powerB…
1.3.6.1.4.1.232.8.2.2.3.1.4ColumncpqSsPowerSupplyStatusread-onlymandatoryStorage System Power Supply Status. The following values are defined: other(1) The agent is unable to determine if this storage system power supply bay is occu…
1.3.6.1.4.1.232.8.2.2.3.1.5ColumncpqSsPowerSupplyUpsStatusread-onlymandatoryStorage System Power Supply Uninterruptible Power Supply (UPS) Status. The following values are defined: other(1) The agent is unable to determine if this powe…
1.3.6.1.4.1.232.8.2.2.3.1.6ColumncpqSsPowerSupplyConditionread-onlymandatoryStorage System Power Supply Condition. This is the condition of the storage system chassis and all of its components. The following values are defined: other(1…
1.3.6.1.4.1.232.8.2.2.3.1.7ColumncpqSsPowerSupplySerialNumberread-onlymandatoryStorage System Power Supply Serial Number. This is the power supply's serial number. This can be used for identification purposes. If the serial number is not …
1.3.6.1.4.1.232.8.2.2.3.1.8ColumncpqSsPowerSupplyBoardRevisionread-onlymandatoryStorage System Power Supply Board Revision. This is the power supply board revision. If the board revision is not supported, the agent will return a NULL strin…
1.3.6.1.4.1.232.8.2.2.3.1.9ColumncpqSsPowerSupplyFirmwareRevisionread-onlymandatoryStorage System Power Supply Firmware Revision. This is the power supply firmware revision. If the firmware revision is not supported, the agent will return a N…
1.3.6.1.4.1.232.8.2.2.4TablecpqSsFanModuleTablenot-accessiblemandatoryStorage System Fan Module Table.
1.3.6.1.4.1.232.8.2.2.4.1RowcpqSsFanModuleEntrynot-accessiblemandatoryStorage System Fan Module Entry.
1.3.6.1.4.1.232.8.2.2.4.1.1ColumncpqSsFanModuleChassisIndexread-onlymandatoryStorage System Fan Module Chassis Index. The chassis index uniquely identifies a storage system chassis.
1.3.6.1.4.1.232.8.2.2.4.1.2ColumncpqSsFanModuleIndexread-onlymandatoryStorage System Fan Module Index. This index uniquely identifies a storage system fan module.
1.3.6.1.4.1.232.8.2.2.4.1.3ColumncpqSsFanModuleStatusread-onlymandatoryStorage System Fan Module Status. The following values are defined: other(1) The agent is unable to determine if this storage system fan module is installed. n…
1.3.6.1.4.1.232.8.2.2.4.1.4ColumncpqSsFanModuleConditionread-onlymandatoryStorage System Fan Module Condition. This is the condition of the storage system fan module. The following values are defined: other(1) The agent does not reco…
1.3.6.1.4.1.232.8.2.2.4.1.5ColumncpqSsFanModuleLocationread-onlymandatoryStorage System Fan Module Location. The following values are defined: other(1) The agent is unable to determine the location of this storage system fan module.…
1.3.6.1.4.1.232.8.2.2.4.1.6ColumncpqSsFanModuleSerialNumberread-onlymandatoryStorage System Fan Module Serial Number. This is the fan module's serial number. This can be used for identification purposes.
1.3.6.1.4.1.232.8.2.2.4.1.7ColumncpqSsFanModuleBoardRevisionread-onlymandatoryStorage System Fan Module Board Revision. This is the fan module board revision.
1.3.6.1.4.1.232.8.2.2.5TablecpqSsTempSensorTablenot-accessiblemandatoryStorage System Temperature Sensor Table.
1.3.6.1.4.1.232.8.2.2.5.1RowcpqSsTempSensorEntrynot-accessiblemandatoryStorage System Temperature Sensor Entry.
1.3.6.1.4.1.232.8.2.2.5.1.1ColumncpqSsTempSensorChassisIndexread-onlymandatoryStorage System Temperature Sensor Chassis Index. The chassis index uniquely identifies a storage system chassis.
1.3.6.1.4.1.232.8.2.2.5.1.2ColumncpqSsTempSensorIndexread-onlymandatoryStorage System Temperature Sensor Index. This index uniquely identifies a temperature sensor.
1.3.6.1.4.1.232.8.2.2.5.1.3ColumncpqSsTempSensorStatusread-onlymandatoryStorage System Temperature Sensor Status. The following values are defined: other(1) The agent is unable to determine if the storage system temperature sensor …
1.3.6.1.4.1.232.8.2.2.5.1.4ColumncpqSsTempSensorConditionread-onlymandatoryStorage System Fan Module Condition. This is the condition of the storage system temperature sensor. The following values are defined: other(1) The agent does …
1.3.6.1.4.1.232.8.2.2.5.1.5ColumncpqSsTempSensorLocationread-onlymandatoryStorage System Fan Module Location. The following values are defined: other(1) The agent is unable to determine the location of this storage system temperature…
1.3.6.1.4.1.232.8.2.2.5.1.6ColumncpqSsTempSensorCurrentValueread-onlymandatoryStorage System Temperature Sensor Current Value. The current value of the temperature sensor in degrees Celsius.
1.3.6.1.4.1.232.8.2.2.5.1.7ColumncpqSsTempSensorLimitValueread-onlymandatoryStorage System Temperature Sensor Limit Value. The limit value of the temperature sensor in degrees Celsius.
1.3.6.1.4.1.232.8.2.2.5.1.8ColumncpqSsTempSensorHysteresisValueread-onlymandatoryStorage System Temperature Sensor Hysteresis Value. The hysteresis value of the temperature sensor in degrees Celsius.
1.3.6.1.4.1.232.8.2.2.6TablecpqSsBackplaneTablenot-accessiblemandatoryStorage System SCSI Backplane Table.
1.3.6.1.4.1.232.8.2.2.6.1RowcpqSsBackplaneEntrynot-accessiblemandatoryStorage System SCSI Backplane Entry.
1.3.6.1.4.1.232.8.2.2.6.1.1ColumncpqSsBackplaneChassisIndexread-onlymandatoryStorage System Backplane Chassis Index. The chassis index uniquely identifies a storage system chassis.
1.3.6.1.4.1.232.8.2.2.6.1.2ColumncpqSsBackplaneIndexread-onlymandatoryStorage System Backplane Index. This index uniquely identifies a storage system backplane.
1.3.6.1.4.1.232.8.2.2.6.1.3ColumncpqSsBackplaneFWRevread-onlymandatoryStorage System Backplane Firmware Revision. This is the revision level of storage system backplane.
1.3.6.1.4.1.232.8.2.2.6.1.4ColumncpqSsBackplaneDriveBaysread-onlymandatoryStorage System Backplane Drive Bays. This is the number of bays on this storage system backplane.
1.3.6.1.4.1.232.8.2.2.6.1.5ColumncpqSsBackplaneDuplexOptionread-onlymandatoryStorage System Backplane Duplex Option. The following values are defined: other (1) The agent is unable to determine if this storage system is duplexed. notDup…
1.3.6.1.4.1.232.8.2.2.6.1.6ColumncpqSsBackplaneConditionread-onlymandatoryStorage System Backplane Condition. This is the overall condition of the backplane. The following values are defined: other(1) The agent does not recognize the…
1.3.6.1.4.1.232.8.2.2.6.1.7ColumncpqSsBackplaneVersionread-onlymandatoryStorage System Backplane Version. This is the version of the drive box back plane.
1.3.6.1.4.1.232.8.2.2.6.1.8ColumncpqSsBackplaneVendorread-onlymandatoryStorage System Backplane Vendor This is the storage box`s vendor name. This can be used for identification purposes.
1.3.6.1.4.1.232.8.2.2.6.1.9ColumncpqSsBackplaneModelread-onlymandatoryStorage System Backplane Model. This is a description of the storage system`s model. This can be used for identification purposes.
1.3.6.1.4.1.232.8.2.2.6.1.10ColumncpqSsBackplaneFanStatusread-onlymandatoryStorage System Backplane Fan Status. This is the current status of the fans in the storage system. This value will be one of the following: other(1) The agent …
1.3.6.1.4.1.232.8.2.2.6.1.11ColumncpqSsBackplaneTempStatusread-onlymandatoryStorage System Backplane Fan Status. This value will be one of the following: other(1) The agent is unable to determine if this storage system has temperature …
1.3.6.1.4.1.232.8.2.2.6.1.12ColumncpqSsBackplaneFtpsStatusread-onlymandatoryStorage System Backplane Fault Tolerant Power Supply Status. This value specifies the overall status of the redundant power supply in a drive box. This value w…
1.3.6.1.4.1.232.8.2.2.6.1.13ColumncpqSsBackplaneSerialNumberread-onlymandatoryStorage System Backplane Serial Number. This is the storage system backplane serial number which is normally displayed on the front bezel. This can be used for…
1.3.6.1.4.1.232.8.2.2.6.1.14ColumncpqSsBackplanePlacementread-onlymandatoryStorage System Backplane Placement. The following values are defined: other(1) The agent is unable to determine if this storage system is located internal or e…
1.3.6.1.4.1.232.8.2.2.6.1.15ColumncpqSsBackplaneBoardRevisionread-onlymandatoryStorage System Backplane Board Revision. This is the board revision of this storage system backplane.
1.3.6.1.4.1.232.8.2.2.6.1.16ColumncpqSsBackplaneSpeedread-onlymandatoryStorage System Backplane Speed. The following values are defined: other(1) The agent is unable to determine the backplane speed for this storage system. ultra3…
1.3.6.1.4.1.232.8.2.2.6.1.17ColumncpqSsBackplaneConnectionTyperead-onlymandatoryBacklane Box Connection Type. The following values are defined: other(1) The agent is unable to determine the type of connection to this backplane. scsiAttache…
1.3.6.1.4.1.232.8.2.2.6.1.18ColumncpqSsBackplaneConnectorread-onlymandatoryBackplane Connector. This is the connector to which the backplane is attached. If the backplane connector cannot be determined, the agent will return a NULL st…
1.3.6.1.4.1.232.8.2.2.6.1.19ColumncpqSsBackplaneOnConnectorread-onlymandatoryBackplane on Connector. The backplane on connector indicates to which backplane instance this table entry belongs. The instances start at one and increment for…
1.3.6.1.4.1.232.8.2.2.6.1.20ColumncpqSsBackplaneLocationStringread-onlymandatoryBackplane Location String. This string describes the location of the backplane in relation to the controller to which it is attached. If the location string ca…
1.3.6.1.4.1.232.8.2.2.7TablecpqSsFibreAttachmentTablenot-accessiblemandatoryStorage System Fibre Attachment Table.
1.3.6.1.4.1.232.8.2.2.7.1RowcpqSsFibreAttachmentEntrynot-accessiblemandatoryStorage System Fibre Attachment Entry.
1.3.6.1.4.1.232.8.2.2.7.1.1ColumncpqSsFibreAttachmentIndexread-onlymandatoryStorage System Fibre Attachment Index. The index uniquely identifies a Fibre Attachment association entry.
1.3.6.1.4.1.232.8.2.2.7.1.2ColumncpqSsFibreAttachmentHostControllerIndexread-onlymandatoryStorage System Fibre Attachment Host Controller Index. The host controller index indicates which host controller is associated with this entry. This is equal t…
1.3.6.1.4.1.232.8.2.2.7.1.3ColumncpqSsFibreAttachmentHostControllerPortread-onlymandatoryStorage System Fibre Attachment Host Controller Port. This is the Fibre port number of the host controller. For each host controller, the port number starts at…
1.3.6.1.4.1.232.8.2.2.7.1.4ColumncpqSsFibreAttachmentDeviceTyperead-onlymandatoryStorage System Fibre Attachment Device Type. This is the type of device associated with this entry. The following values are defined: other(1) The agent is una…
1.3.6.1.4.1.232.8.2.2.7.1.5ColumncpqSsFibreAttachmentDeviceIndexread-onlymandatoryStorage System Fibre Attachment Device Index. The is the index for the Fibre attached device. For a Fibre attached storage system, this is equal to cpqSsChassi…
1.3.6.1.4.1.232.8.2.2.7.1.6ColumncpqSsFibreAttachmentDevicePortread-onlymandatoryStorage System Fibre Attachment Device Port. This is the Fibre port on a device. For a Fibre attached storage system, this is equal to cpqFcaCntlrBoxIoSlot fro…
1.3.6.1.4.1.232.8.2.2.8TablecpqSsScsiAttachmentTablenot-accessiblemandatoryStorage System SCSI Attachment Table.
1.3.6.1.4.1.232.8.2.2.8.1RowcpqSsScsiAttachmentEntrynot-accessiblemandatoryStorage System SCSI Attachment Entry.
1.3.6.1.4.1.232.8.2.2.8.1.1ColumncpqSsScsiAttachmentIndexread-onlymandatoryStorage System SCSI Attachment Index. The index uniquely identifies a SCSI Attachment association entry.
1.3.6.1.4.1.232.8.2.2.8.1.2ColumncpqSsScsiAttachmentControllerIndexread-onlymandatoryStorage System SCSI Attachment Controller Index. The controller index indicates which internal array controller is associated with this entry. This is equal to…
1.3.6.1.4.1.232.8.2.2.8.1.3ColumncpqSsScsiAttachmentControllerPortread-onlymandatoryStorage System SCSI Attachment Controller Port. The controller port indicates which SCSI port of an internal controller is associated with this entry.
1.3.6.1.4.1.232.8.2.2.8.1.4ColumncpqSsScsiAttachmentControllerTargetread-onlymandatoryStorage System SCSI Attachment Controller Target. The controller target indicates which SCSI target is associated with this entry.
1.3.6.1.4.1.232.8.2.2.8.1.5ColumncpqSsScsiAttachmentControllerLunread-onlymandatoryStorage System SCSI Attachment Controller Lun. The controller Lun indicates which SCSI Lun is associated with this entry.
1.3.6.1.4.1.232.8.2.2.8.1.6ColumncpqSsScsiAttachmentChassisIndexread-onlymandatoryStorage System SCSI Attachment Chassis Index. The is the index for the SCSI attached storage system. This is equal to cpqSsChassisIndex from the Storage System…
1.3.6.1.4.1.232.8.2.2.8.1.7ColumncpqSsScsiAttachmentChassisIoSlotread-onlymandatoryStorage System SCSI Attachment Chassis I/O Slot. This is the I/O slot in the SCSI attached storage system. This is equal to cpqFcaCntlrBoxIoSlot from the Fibre…
1.3.6.1.4.1.232.8.2.2.8.1.8ColumncpqSsScsiAttachmentPathStatusread-onlymandatoryStorage System SCSI Attachment Path Status. This is the status of this path to the chassis. The following values are defined: other(1) The agent does not recog…
1.3.6.1.4.1.232.8.2.2.8.1.9ColumncpqSsScsiAttachmentPathConditionread-onlymandatoryStorage System SCSI Attachment Path Condition. This is the condition of this path to the chassis.
1.3.6.1.4.1.232.8.2.3TablecpqSsDrvBoxPathTablenot-accessiblemandatoryDrive Box Access Path Table.
1.3.6.1.4.1.232.8.2.3.1RowcpqSsDrvBoxPathEntrynot-accessiblemandatoryDrive Box Access Path Entry.
1.3.6.1.4.1.232.8.2.3.1.1ColumncpqSsDrvBoxPathCntlrIndexread-onlymandatoryDrive Box Access Path Controller Index. The controller index indicates to which adapter card instance this table entry belongs.
1.3.6.1.4.1.232.8.2.3.1.2ColumncpqSsDrvBoxPathBoxIndexread-onlymandatoryDrive Box Access Path Box Index. The box index indicates to which box instance on an adapter card this table entry belongs. The value of this index is the same…
1.3.6.1.4.1.232.8.2.3.1.3ColumncpqSsDrvBoxPathIndexread-onlymandatoryDrive Box Access Path Index. This path index keeps track of multiple instances of access paths from a controller to a storage box. This number, along with the …
1.3.6.1.4.1.232.8.2.3.1.4ColumncpqSsDrvBoxPathStatusread-onlymandatoryDrive Box Access Path Status. This shows the status of the drive box access path. The following values are valid: Other (1) Indicates that the instrument agent…
1.3.6.1.4.1.232.8.2.3.1.5ColumncpqSsDrvBoxPathCurrentRoleread-onlymandatoryDrive Box Access Path Current Role. This shows the current role of drive box acess path. The following values are valid: Other (1) Indicates that the instrumen…
1.3.6.1.4.1.232.8.2.3.1.6ColumncpqSsDrvBoxPathHostConnectorread-onlymandatoryDrive Box Access Path Host Connector. This is the host connector to which the access path is ultimately attached. If the host connector cannot be determined, t…
1.3.6.1.4.1.232.8.2.3.1.7ColumncpqSsDrvBoxPathBoxOnConnectorread-onlymandatoryDrive Box Access Path Box on Connector. The box on connector indicates to which box instance this access path belongs.
1.3.6.1.4.1.232.8.2.3.1.8ColumncpqSsDrvBoxPathLocationStringread-onlymandatoryDrive Box Access Path Location String. This string describes drive box access path in relation to the controller to which it is attached. If the location strin…
1.3.6.1.4.1.232.8.3NodecpqSsTrap
1.3.6.1.4.1.232.8.3.1ScalarcpqSsTrapPktsread-onlydeprecatedThe total number of trap packets issued by the enterprise since the instrument agent was loaded.
1.3.6.1.4.1.232.8.3.2ScalarcpqSsTrapLogMaxSizeread-onlydeprecatedThe maximum number of entries that will currently be kept in the trap log. If the maximum size has been reached and a new trap occurs the oldest trap will be r…
1.3.6.1.4.1.232.8.3.3TablecpqSsTrapLogTablenot-accessibledeprecatedAn ordered list of trap log entries (conceptually a queue). The trap log entries will be kept in the order in which they were generated with the most recent tr…
1.3.6.1.4.1.232.8.3.3.1RowcpqSsTrapLogEntrynot-accessibledeprecatedA description of a trap event.
1.3.6.1.4.1.232.8.3.3.1.1ColumncpqSsTrapLogIndexread-onlydeprecatedThe value of this object uniquely identifies this trapLogEntry at this time. The most recent trap will have an index of 1 and the oldest trap will have an inde…
1.3.6.1.4.1.232.8.3.3.1.2ColumncpqSsTrapTyperead-onlydeprecatedThe type of the trap event that this entry describes. This number refers to an entry in a list of traps enumerating the possible traps the agent may issue.
1.3.6.1.4.1.232.8.3.3.1.3ColumncpqSsTrapTimeread-onlydeprecatedThe time of the trap event that this entry describes. The time is given in year (first octet), month, day of month, hour, minute, second (last octet) order. Ea…
1.3.6.1.4.1.232.8.4NodecpqSsRaidSystem
1.3.6.1.4.1.232.8.4.1TablecpqSsRaidSystemTablenot-accessiblemandatoryRAID Storage System Table.
1.3.6.1.4.1.232.8.4.1.1RowcpqSsRaidSystemEntrynot-accessiblemandatoryRAID Storage System Entry.
1.3.6.1.4.1.232.8.4.1.1.1ColumncpqSsRaidSystemIndexread-onlymandatoryRAID Storage System Index. The RAID Storage System index indicates to which storage system instance this table entry belongs.
1.3.6.1.4.1.232.8.4.1.1.2ColumncpqSsRaidSystemNameread-onlymandatoryRAID Storage System Name. This is a description of the RAID Storage System`s name. This can be used for identification purposes.
1.3.6.1.4.1.232.8.4.1.1.3ColumncpqSsRaidSystemStatusread-onlymandatoryRAID Storage System Status. This is the current status of the RAID Storage System. This value will be one of the following: other(1) Indicates that the agent d…
1.3.6.1.4.1.232.8.4.1.1.4ColumncpqSsRaidSystemConditionread-onlymandatoryRAID Storage System Condition. This is the overall condition of the storage system. The following values are defined: other(1) The agent does not recognize the…
1.3.6.1.4.1.232.8.4.1.1.5ColumncpqSsRaidSystemCntlr1SerialNumberread-onlymandatoryRAID Storage System Controller 1 Serial Number. This is the controller number 1`s serial number which is normally display on the front panel. This can be used …
1.3.6.1.4.1.232.8.4.1.1.6ColumncpqSsRaidSystemCntlr2SerialNumberread-onlymandatoryRAID Storage System Controller 2 Serial Number. This is the controller number 2`s serial number which is normally display on the front panel. This can be used …
1.3.6.1.4.1.232.8001NodecpqSs2FanStatusChangeStorage System fan status change. The agent has detected a change in the Fan Status of a storage system. The variable cpqSsBoxFanStatus indicates the current f…
1.3.6.1.4.1.232.8002NodecpqSsTempFailedStorage System temperature failure. The agent has detected that a temperature status has been set to failed. The storage system will be shutdown.
1.3.6.1.4.1.232.8003NodecpqSsTempDegradedStorage System temperature degraded. The agent has detected a temperature status that has been set to degraded. The storage system`s temperature is outside of …
1.3.6.1.4.1.232.8004NodecpqSsTempOkStorage System temperature ok. The temperature status has been set to OK. The storage system`s temperature has returned to normal operating range. It may be re…
1.3.6.1.4.1.232.8005NodecpqSsSidePanelInPlaceStorage System side panel is in place. The side panel status has been set to in place. The storage system`s side panel has returned to a properly installed sta…
1.3.6.1.4.1.232.8006NodecpqSsSidePanelRemovedStorage System side panel is removed. The side panel status has been set to removed. The storage system`s side panel is not in a properly installed state. This…
1.3.6.1.4.1.232.8007NodecpqSsPwrSupplyDegradedA storage system power supply status has been set to degraded.
1.3.6.1.4.1.232.8008NodecpqSs3FanStatusChangeStorage System fan status change. The agent has detected a change in the Fan Status of a storage system. The variable cpqSsBoxFanStatus indicates the current f…
1.3.6.1.4.1.232.8009NodecpqSs3TempFailedStorage System temperature failure. The agent has detected that a temperature status has been set to failed. The storage system will be shutdown. User Action: …
1.3.6.1.4.1.232.8010NodecpqSs3TempDegradedStorage System temperature degraded. The agent has detected a temperature status that has been set to degraded. The storage system`s temperature is outside of …
1.3.6.1.4.1.232.8011NodecpqSs3TempOkStorage System temperature ok. The temperature status has been set to OK. The storage system`s temperature has returned to normal operating range. It may be re…
1.3.6.1.4.1.232.8012NodecpqSs3SidePanelInPlaceStorage System side panel is in place. The side panel status has been set to in place. The storage system`s side panel has returned to a properly installed sta…
1.3.6.1.4.1.232.8013NodecpqSs3SidePanelRemovedStorage System side panel is removed. The side panel status has been set to removed. The storage system`s side panel is not in a properly installed state. This…
1.3.6.1.4.1.232.8014NodecpqSs3PwrSupplyDegradedA storage system power supply status has been set to degraded.
1.3.6.1.4.1.232.8015NodecpqSs4PwrSupplyDegradedA storage system power supply status has been set to degraded. User Action: Take action to restore power or replace any failed storage system power supply.
1.3.6.1.4.1.232.8016NodecpqSsExFanStatusChangeStorage system fan status change. The agent has detected a change in the Fan Module Status of a storage system. The variable cpqSsFanModuleStatus indicates the…
1.3.6.1.4.1.232.8017NodecpqSsExPowerSupplyStatusChangeStorage system power supply status change. The agent has detected a change in the power supply status of a storage system. The variable cpqSsPowerSupplyStatus …
1.3.6.1.4.1.232.8018NodecpqSsExPowerSupplyUpsStatusChangeStorage system power supply UPS status change. The agent has detected a change status of a UPS attached to a storage system power supply. The variable cpqSsPow…
1.3.6.1.4.1.232.8019NodecpqSsExTempSensorStatusChangeStorage system temperature sensor status change. The agent has detected a change in the status of a storage system temperature sensor. The variable cpqSsTempSe…
1.3.6.1.4.1.232.8020NodecpqSsEx2FanStatusChangeStorage system fan status change. The agent has detected a change in the fan module status of a storage system. The variable cpqSsFanModuleStatus indicates the…
1.3.6.1.4.1.232.8021NodecpqSsEx2PowerSupplyStatusChangeStorage system power supply status change. The agent has detected a change in the power supply status of a storage system. The variable cpqSsPowerSupplyStatus …
1.3.6.1.4.1.232.8022NodecpqSsExBackplaneFanStatusChangeStorage system fan status change. The agent has detected a change in the fan status of a storage system. The variable cpqSsBackplaneFanStatus indicates the cur…
1.3.6.1.4.1.232.8023NodecpqSsExBackplaneTempStatusChangeStorage system temperature status change. The agent has detected a change in the status of the temperature in a storage system. The variable cpqSsBackplaneTemp…
1.3.6.1.4.1.232.8024NodecpqSsExBackplanePowerSupplyStatusChangeStorage system power supply status change. The agent has detected a change in the power supply status of a storage system. The variable cpqSsBackplaneFtpsStatu…
1.3.6.1.4.1.232.8025NodecpqSsExRecoveryServerStatusChangeStorage system recovery server option status change. The agent has detected a change in the recovery server option status of a storage system. The variable cpq…
1.3.6.1.4.1.232.8026NodecpqSs5FanStatusChangeStorage System fan status change. The agent has detected a change in the Fan Status of a storage system. The variable cpqSsBoxFanStatus indicates the current f…
1.3.6.1.4.1.232.8027NodecpqSs5TempStatusChangeStorage System temperature status change. The agent has detected a change in the temperature status of a storage system. The variable cpqSsBoxTempStatus indica…
1.3.6.1.4.1.232.8028NodecpqSs5PwrSupplyStatusChangeStorage system power supply status change. The agent has detected a change in the power supply status of a storage system. The variable cpqSsBoxFltTolPwrSupply…
1.3.6.1.4.1.232.8029NodecpqSs6FanStatusChangeStorage System fan status change. The agent has detected a change in the Fan Status of a storage system. The variable cpqSsBoxFanStatus indicates the current f…
1.3.6.1.4.1.232.8030NodecpqSs6TempStatusChangeStorage System temperature status change. The agent has detected a change in the temperature status of a storage system. The variable cpqSsBoxTempStatus indica…
1.3.6.1.4.1.232.8031NodecpqSs6PwrSupplyStatusChangeStorage system power supply status change. The agent has detected a change in the power supply status of a storage system. The variable cpqSsBoxFltTolPwrSupply…
1.3.6.1.4.1.232.8032NodecpqSsConnectionStatusChangeStorage system connection status change. The agent has detected a change in the connection status of a storage system. The variable cpqSSboxConnectionStatus in…
1.3.6.1.4.1.232.8033NodecpqSsGSIStatusChangeStorage system Global Service Indicator Status Change. The agent has detected a change in the Global Service Indicator status of a storage system. The variable…