MIB Viewer

CT-ELS100-MIB

146 objects
No module-level DESCRIPTION found.
OIDNameAccessStatusDescription
1.3.6.1.2.1.1.2.1NodekxPortFunctionsTrapSent whenever the current functional state (active protocols) of the port has changed.
1.3.6.1.2.1.1.2.2NodekxRxQueuesTrapSent whenever the number of times that the port's receiver has stopped receiving packets due to buffer space shortages has exceeded the port's limit.
1.3.6.1.2.1.1.2.3NodekxTxStormFlagTrapSent whenever multicast storm protection has been invoked for the port.
1.3.6.1.2.1.1.2.4NodekxTxCongestsTrapSent whenever packets destined for the unit itself were discarded due to lack of buffer space.
1.3.6.1.2.1.1.2.5NodekxTrunkStateTrapA trunking state change transition has occurred. The possible transitions are: Closed-Oneway Oneway-Perturbed Perturbed-Joined Joined-Helddown Closed-Helddown …
1.3.6.1.2.1.1.2.6NodekxTrunkBridgeAddrTrapThe associated trunking MAC address of the bridge ID of the remote bridge has changed.
1.3.6.1.2.1.1.2.7NodekxTrunkIPAddrTrapThe associated trunking IP address of the remote bridge has changed.
1.3.6.1.2.1.1.2.8NodekxTrunkErrorTrapAn error has occurred in trunking.
1.3.6.1.2.1.1.2.9NodekxTrunkLinkOrdinalTrapThe port's index in the trunking group has changed.
1.3.6.1.2.1.1.2.10NodekxTrunkLinkCountTrapThe number of ports in the trunking group has changed.
1.3.6.1.2.1.1.2.11NodekxDiagUnitBootedTrapThe unit has booted. kxadminFatalErr contains information about why the unit rebooted.
1.3.6.1.2.1.1.2.12NodekxStorageFailureTrapSent if the unit's Configuration EEPROM has failed. The unit will not be able to reboot, and must be returned to the factory.
1.3.6.1.2.1.1.2.13NodekxIfErrorsTrapSent whenever the number of hardware errors in received and transmitted packets has exceeded the port's limit.
1.3.6.1.4.1.97Nodesigma
1.3.6.1.4.1.97.1Nodesys
1.3.6.1.4.1.97.1.1ScalarsysIDread-onlymandatoryAn integer which serves to identify the type of SmartStack.
1.3.6.1.4.1.97.1.2ScalarsysResetread-writemandatoryThe time, in centiseconds, before the device should reboot. A GetResponse value of zero indicates that no reboot time has been specified.
1.3.6.1.4.1.97.1.3ScalarsysTrapPortread-writemandatoryZero, or the UDP port number to which a second copy of SNMP traps should be sent. Valid values are zero through 65535.
1.3.6.1.4.1.97.8Nodeels-100
1.3.6.1.4.1.97.8.1Nodekxhw
1.3.6.1.4.1.97.8.1.1ScalarkxhwDiagCoderead-onlymandatoryAdditional diagnostics information concerning the slot's module.
1.3.6.1.4.1.97.8.1.2ScalarkxhwManufDataread-onlymandatoryA 24-byte array which contains the part number, serial number and hardware revision level of this module.
1.3.6.1.4.1.97.8.1.3ScalarkxhwPortCountread-onlymandatory
1.3.6.1.4.1.97.8.2Nodekxsw
1.3.6.1.4.1.97.8.2.1ScalarkxswNumberread-onlymandatoryThe number of file sets. The default is 2.
1.3.6.1.4.1.97.8.2.2TablekxswFilesetTablenot-accessiblemandatoryA list of the software file sets stored. The first file set refers to the one that was used when ELS-100 last booted. The second file set refers to the one whi…
1.3.6.1.4.1.97.8.2.2.1RowkxswFilesetEntrynot-accessiblemandatoryA set of objects for each file set.
1.3.6.1.4.1.97.8.2.2.1.1ColumnkxswIndexread-onlymandatoryThe file set number, beginning with 1 for the first file set. This number always matches the instance of the swFiles. For example, {swIndex 2} contains the val…
1.3.6.1.4.1.97.8.2.2.1.2ColumnkxswDescread-onlymandatoryThe description (0-255 bytes) of the software file set.
1.3.6.1.4.1.97.8.2.2.1.3ColumnkxswCountread-onlymandatoryThe number of files in the file set. This number may range from 1 to 255.
1.3.6.1.4.1.97.8.2.2.1.4ColumnkxswTyperead-onlymandatoryThe types of the files within the file set.
1.3.6.1.4.1.97.8.2.2.1.5ColumnkxswSizesread-onlymandatoryAn array (4 octets per file), containing the size of each of the files. Each size is encoded as a series of 4 bytes, which should be converted into a 32 bit in…
1.3.6.1.4.1.97.8.2.2.1.6ColumnkxswStartsread-onlymandatoryAn array (4 octets per file), containing the software's execution starting address of each of the files. Each address is encoded as a series of 4 bytes, which …
1.3.6.1.4.1.97.8.2.2.1.7ColumnkxswBasesread-onlymandatoryAn array (4 octets per file), containing the software's base loading address of each of the files. Each address is encoded as a series of 4 bytes, which should…
1.3.6.1.4.1.97.8.2.2.1.8ColumnkxswFlashBankread-onlymandatoryThe bank number where the software file set resides.
1.3.6.1.4.1.97.8.3Nodekxadmin
1.3.6.1.4.1.97.8.3.1ScalarkxadminFatalErrread-onlymandatoryThis is a 32 byte array which contains information about the cause of the previous system reset. This will describe the circumstances which forced the system s…
1.3.6.1.4.1.97.8.3.2ScalarkxadminAnyPassread-writemandatoryThe authentication password (0-24 bytes) which must match the community name in an SNMP PDU, in order for the operation to be performed. A zero length password…
1.3.6.1.4.1.97.8.3.3ScalarkxadminGetPassread-writemandatoryThe authentication password (0-24 bytes) which must match the community name in an SNMP Get PDU (except for Debug or password parameters). A zero length passwo…
1.3.6.1.4.1.97.8.3.4ScalarkxadminNMSIPAddrread-writemandatoryThe address of the NMS to which Trap PDUs are to be sent. A value of zero indicates that Trap PDUs should be sent to the NMS last heard from.
1.3.6.1.4.1.97.8.3.5ScalarkxadminStorageFailureread-onlymandatoryWhether the ELS-100's storage facility for its configuration parameters has failed (the ELS-100 may not be able to reboot after such a failure).
1.3.6.1.4.1.97.8.3.6ScalarkxadminAuthenticationFailureread-onlymandatoryAll nulls, or the IP source address within the last SNMP PDU which caused an SNMP authentication failure.
1.3.6.1.4.1.97.8.3.7ScalarkxadminNAMReceiveCongestsread-onlymandatory
1.3.6.1.4.1.97.8.3.8ScalarkxadminArpEntriesread-onlymandatoryThe number of ARP entries for all interfaces.
1.3.6.1.4.1.97.8.3.9ScalarkxadminArpStaticsread-onlymandatoryThe number of statically defined ARP entries for all interfaces.
1.3.6.1.4.1.97.8.3.10ScalarkxadminArpOverflowsread-onlymandatoryThe number of times a ARP entry could not be learned due to insufficient address table space.
1.3.6.1.4.1.97.8.3.11ScalarkxadminRipPreferenceread-writemandatoryThe value to assign to ipRouteMetric2, when adding a RIP-learned entry to the IP Routing Table.
1.3.6.1.4.1.97.8.3.12ScalarkxadminRipRouteDiscardsread-onlymandatoryThe number of times a route learned via RIP was not added to the IP Routing Table due to insufficient Routing Table space.
1.3.6.1.4.1.97.8.3.13ScalarkxadminRebootConfigread-writemandatoryThe configuration file that will be used when the ELS-100 reboots. This parameter is normally automatically set by the ELS-100; however, an NMS may explicitly …
1.3.6.1.4.1.97.8.3.14ScalarkxadminDisableButtonread-writemandatory
1.3.6.1.4.1.97.8.3.15ScalarkxadminButtonSelectionread-writemandatory
1.3.6.1.4.1.97.8.3.16ScalarkxadminLEDProgramOptionread-writemandatory
1.3.6.1.4.1.97.8.4Nodekxswdis
1.3.6.1.4.1.97.8.4.1ScalarkxswdisDescread-onlymandatoryThe description (0-32 bytes) of the software set currently being downloaded, or a description of the software set last downloaded since the ELS100-16 booted.
1.3.6.1.4.1.97.8.4.2ScalarkxswdisAccessread-writemandatoryThe version of software that may be downloaded. Attempts to download other versions of software will be rejected. The value for swdisAccess is embedded within …
1.3.6.1.4.1.97.8.4.3ScalarkxswdisWriteStatusread-onlymandatoryThe status of the erase/write operation.
1.3.6.1.4.1.97.8.4.4ScalarkxswdisConfigIpread-writemandatoryThe IP address of the NMS (i.e., any IP host) that is allowed to use TFTP to send/retrieve the configuration file of the ELS100-16. A value of 0.0.0.0 (which i…
1.3.6.1.4.1.97.8.4.5ScalarkxswdisConfigRetryTimeread-writemandatoryThe number of seconds that the ELS-100 will wait for an acknowledgment before it retransmits an unacknowledged TFTP data block. The factory specified default i…
1.3.6.1.4.1.97.8.4.6ScalarkxswdisConfigTotalTimeoutread-writemandatoryThe number of seconds that the ELS-100 will wait for an acknowledgment to a data block before it cancels a TFTP session. The factory specified default is 25 se…
1.3.6.1.4.1.97.8.5Nodekxaddr
1.3.6.1.4.1.97.8.5.1ScalarkxaddrStaticsread-onlymandatoryThe number of static addresses which are currently stored in the ELS100-16.
1.3.6.1.4.1.97.8.5.2ScalarkxaddrDynamicsread-onlymandatoryThe number of learned addresses in the address table.
1.3.6.1.4.1.97.8.5.3ScalarkxaddrDynamicMaxread-writemandatoryThe maximum number of spanning tree addresses which have been learned since the ELS100-16 was last booted (or this parameter was last reset by the NMS).
1.3.6.1.4.1.97.8.5.4ScalarkxaddrDynamicOverflowsread-onlymandatoryThe number times an address was not learned due to insufficient address table space.
1.3.6.1.4.1.97.8.5.5ScalarkxaddrFlagsread-writemandatoryFlags to describe the use and control of this address entry. Each bit has a different meaning. The NMS must always set either entry-static, entry-none, or entr…
1.3.6.1.4.1.97.8.5.6ScalarkxaddrMACread-writemandatoryThe MAC address for this address definition.
1.3.6.1.4.1.97.8.5.7ScalarkxaddrPortread-writemandatoryThe port through which this address is connected to the ELS100 (only valid for entry-dynamic-local, entry-statistics, and entry-port entries).
1.3.6.1.4.1.97.8.5.8ScalarkxaddrOperationread-writemandatoryThe operation to be performed upon the described address. The possibilities include: read-random (1), read-next (2), update (4), delete (5), read-block (6).
1.3.6.1.4.1.97.8.5.9ScalarkxaddrIndexread-writemandatoryThe index number to be used for read-next and read-block operations. When the ELS-100 boots, addrIndex is initialized to -1.
1.3.6.1.4.1.97.8.5.10ScalarkxaddrNextread-writemandatoryThe next value to use for addrIndex, when you use read-next or read-block operations to read the address table. When the ELS-100 boots, addrNext is initialized…
1.3.6.1.4.1.97.8.5.11ScalarkxaddrBlockSizeread-writemandatoryThe number of addresses contained by addrBlock. This parameter is only used for dumping blocks of MAC addresses.
1.3.6.1.4.1.97.8.5.12ScalarkxaddrBlockread-writemandatoryA series of 0-700 octets, which represents 0-100 addresses. Each address consists of a 6 octet MAC address followed by a 1 byte port number. If the port number…
1.3.6.1.4.1.97.8.6Nodekxif
1.3.6.1.4.1.97.8.6.1TablekxifTablenot-accessiblemandatoryA list of interface entries; one per port.
1.3.6.1.4.1.97.8.6.1.1RowkxifEntrynot-accessiblemandatoryA set of objects for an interface entry.
1.3.6.1.4.1.97.8.6.1.1.1ColumnkxifIndexread-onlymandatoryThe port number, beginning with 1 for the first port.
1.3.6.1.4.1.97.8.6.1.1.2ColumnkxifRxCntread-onlymandatoryThe number of small data buffers for receiving packets.
1.3.6.1.4.1.97.8.6.1.1.3ColumnkxifTxCntread-onlymandatoryThe maximum size of the port's transmit queue, i.e., the number of packets that can be in the port's transmit queue, waiting to be transmitted.
1.3.6.1.4.1.97.8.6.1.1.4ColumnkxifThresholdread-writemandatoryMaximum number of combined receive and transmit packet hardware errors before an alarm should be generated.
1.3.6.1.4.1.97.8.6.1.1.5ColumnkxifThresholdTimeread-writemandatoryThe time period (in seconds) to which kxifThreshold applies. A value of zero will disable the kxifThreshold alarm.
1.3.6.1.4.1.97.8.6.1.1.6ColumnkxifRxQueueThreshread-writemandatoryMaximum number of receive packet queue overflow errors before an alarm should be generated.
1.3.6.1.4.1.97.8.6.1.1.7ColumnkxifRxQueueThreshTimeread-writemandatoryThe time period (in seconds) to which kxifRxQueueThresh applies. A value of zero will disable the kxifRxQueueThresh alarm.
1.3.6.1.4.1.97.8.6.1.1.8ColumnkxifFunctionread-onlymandatoryThe current functional state (protocols which have been activated and are operational) of the port. The following values or combinations are supported: 0x0001 …
1.3.6.1.4.1.97.8.6.1.1.9ColumnkxifStatisticsTimeread-onlymandatoryLength of time during which statistics were collected.
1.3.6.1.4.1.97.8.7Nodekxuart
1.3.6.1.4.1.97.8.7.1TablekxuartTablenot-accessiblemandatoryA list of interface entries; one per UART port.
1.3.6.1.4.1.97.8.7.1.1RowkxuartEntrynot-accessiblemandatoryA set of objects for an interface entry.
1.3.6.1.4.1.97.8.7.1.1.1ColumnkxuartIndexread-onlymandatoryThe ELS-100's port number of the port.
1.3.6.1.4.1.97.8.7.1.1.2ColumnkxuartBaudread-writemandatoryThis is the desired baud rate. Only 1200 baud through 19,200 baud are supported by the ELS-100.
1.3.6.1.4.1.97.8.7.1.1.3ColumnkxuartAlignmentErrorsread-onlymandatoryNumber of received packets with frame alignment errors, since the port was last enabled.
1.3.6.1.4.1.97.8.7.1.1.4ColumnkxuartOverrunErrorsread-onlymandatoryNumber of received packets with data overrun errors, since the port was last enabled.
1.3.6.1.4.1.97.8.8Nodekxproto
1.3.6.1.4.1.97.8.8.1TablekxprotoTablenot-accessiblemandatoryThis table contains configuration information specifying the types of protocols used to bridge and filter frames for each port.
1.3.6.1.4.1.97.8.8.1.1RowkxprotoEntrynot-accessiblemandatoryEach entry in this table specifies which protocols are used by a particular port in the SmartStack.
1.3.6.1.4.1.97.8.8.1.1.1ColumnkxprotoIfIndexread-onlymandatoryIdentifies the interface (port) to which this entry's information belongs. The value of this variable corresponds to ifIndex, as well as most of the other port…
1.3.6.1.4.1.97.8.8.1.1.2ColumnkxprotoBridgeread-writemandatoryDefines the bridging method to be applied to frames received at, or destined for, this port. Ports may be configured for transparent or none. The UART may only…
1.3.6.1.4.1.97.8.8.1.1.3ColumnkxprotoSuppressBpduread-writemandatoryAllows transmission of spanning tree protocol packets to be suppressed. If normal(1), 802.1d spanning tree packets are transmitted as usual. If suppressed(2), …
1.3.6.1.4.1.97.8.8.1.1.4ColumnkxprotoRipListenread-writemandatorySpecifies whether the port should listen for internet Routing Information Protocol (RFC-1058) packets, in order to build the routing table for the unit.
1.3.6.1.4.1.97.8.8.1.1.5ColumnkxprotoTrunkingread-writemandatorySpecifies whether SmartStack trunking protocol (an extension to the standard Spanning Tree) is to be used over this port.
1.3.6.1.4.1.97.8.9Nodekxtrunk
1.3.6.1.4.1.97.8.9.1TablekxtrunkTablenot-accessiblemandatoryThis table describes the trunking status and attributes of the interfaces that are configured for bridge trunking.
1.3.6.1.4.1.97.8.9.1.1RowkxtrunkEntrynot-accessiblemandatoryAn entry exists in this table for each physical interface (port) that is configured for trunking.
1.3.6.1.4.1.97.8.9.1.1.1ColumnkxtrunkIfIndexread-onlymandatoryIdentifies a physical interface (port) which is configured for LAN trunking. The value of this variable corresponds to ifIndex, as well as most of the other po…
1.3.6.1.4.1.97.8.9.1.1.2ColumnkxtrunkStateread-onlymandatoryIf off(1) then this link has not been enabled for trunking. If closed(2) then this link has not yet received any Trunking PDUs. If oneway(3) then incoming Trun…
1.3.6.1.4.1.97.8.9.1.1.3ColumnkxtrunkRemoteBridgeAddrread-onlymandatoryThe MAC address portion of the bridge ID of the remote bridge.
1.3.6.1.4.1.97.8.9.1.1.4ColumnkxtrunkRemoteIpread-onlymandatoryThe IP address of the remote bridge, as reported by that bridge for administrative purposes.
1.3.6.1.4.1.97.8.9.1.1.5ColumnkxtrunkLastErrorread-onlymandatoryThe last reason for failure when the link is in closed, oneway, or helddown state.
1.3.6.1.4.1.97.8.9.1.1.6ColumnkxtrunkLinkOrdinalread-onlymandatoryThe position of this link within the trunk group.
1.3.6.1.4.1.97.8.9.1.1.7ColumnkxtrunkLinkCountread-onlymandatoryThe number of links within the trunk group.
1.3.6.1.4.1.97.8.9.1.1.8ColumnkxtrunkLastChangeread-onlymandatoryThe number of seconds since kxtrunkState changed.
1.3.6.1.4.1.97.8.10Nodekxworkgroup
1.3.6.1.4.1.97.8.10.1ScalarkxWorkGroupNextNumberread-onlymandatoryThe next available workgroup number to be used. When creating a new workgroup, it is recommended to read the value of the variable and use it to key into the w…
1.3.6.1.4.1.97.8.10.2ScalarkxWorkGroupCurrentCountread-onlymandatoryThe total number of workgroups currently defined.
1.3.6.1.4.1.97.8.10.3ScalarkxWorkGroupMaxCountread-onlymandatoryThe maximum number of workgroups allowed.
1.3.6.1.4.1.97.8.10.4TablekxWorkGroupTablenot-accessiblemandatoryThis table contains work group definitions for the interfaces.
1.3.6.1.4.1.97.8.10.4.1RowkxWorkGroupEntrynot-accessiblemandatoryEach entry in this table contains a definition of a work group.
1.3.6.1.4.1.97.8.10.4.1.1ColumnkxWorkGroupNumberread-writemandatoryAn integer that identifies the work group, used as an index to this table.
1.3.6.1.4.1.97.8.10.4.1.2ColumnkxWorkGroupNameread-writemandatoryA 1-16 character work group name.
1.3.6.1.4.1.97.8.10.4.1.3ColumnkxWorkGroupPortsread-writemandatoryA list of all ports within the group. The first octet specified ports 1-8, the second 9-16, etc.
1.3.6.1.4.1.97.8.10.4.1.4ColumnkxWorkGroupTyperead-writemandatoryThe type of work group: all - no additional information needs to be supplied.
1.3.6.1.4.1.97.8.11NodekxtrapMgt
1.3.6.1.4.1.97.8.11.1TablekxtrapControlTablenot-accessiblemandatoryThis table contains information about the severity of each trap and whether the trap is currently enabled.
1.3.6.1.4.1.97.8.11.1.1RowkxtrapControlEntrynot-accessiblemandatory
1.3.6.1.4.1.97.8.11.1.1.1ColumnkxtrapIndexread-onlymandatoryThe specific trap number.
1.3.6.1.4.1.97.8.11.1.1.2ColumnkxtrapEnabledread-writemandatoryEnable or disable the generation of this trap.
1.3.6.1.4.1.97.8.11.1.1.3ColumnkxtrapSeverityread-writemandatoryA user-definable severity, indicating the importance of the trap.
1.3.6.1.4.1.97.8.11.1.1.4ColumnkxtrapTextread-onlymandatoryA description of the trap.
1.3.6.1.4.1.97.8.11.2TablekxtrapSeverityControlTablenot-accessiblemandatoryThis table contains information about whether a class of traps of a particular severity is enabled or disabled.
1.3.6.1.4.1.97.8.11.2.1RowkxtrapSeverityControlEntrynot-accessiblemandatory
1.3.6.1.4.1.97.8.11.2.1.1ColumnkxtrapSeverityControlSeverityread-writemandatoryA user-definable severity, indicating the importance of the trap.
1.3.6.1.4.1.97.8.11.2.1.2ColumnkxtrapSeverityEnableread-writemandatoryEnable or disable all traps of a given severity level.
1.3.6.1.4.1.97.8.11.3ScalarkxtrapIncludeTextread-writemandatoryWhether or not a formatted text string is included in the trap PDU.
1.3.6.1.4.1.97.8.11.4ScalarkxtrapTimeread-writemandatoryThe time, in centiseconds, which should expire between the sending of traps.
1.3.6.1.4.1.97.8.11.5ScalarkxtrapRetryread-writemandatoryThe number of times any enterprise-specific trap is to be sent for a given event. PDUs are retried using a truncated exponential backoff: 2 seconds, 4 seconds,…
1.3.6.1.4.1.97.8.11.6ScalarkxtrapNumberread-onlymandatoryThe number of traps that are in the kxtrapTable.
1.3.6.1.4.1.97.8.11.7TablekxtrapTablenot-accessiblemandatoryThis table contains the latest traps that have been generated.
1.3.6.1.4.1.97.8.11.7.1RowkxtrapEntrynot-accessiblemandatory
1.3.6.1.4.1.97.8.11.7.1.1ColumnkxtrapEntryIndexread-onlymandatoryA number representing the order in which the trap occurred in time. This 32 bit number can wrap.
1.3.6.1.4.1.97.8.11.7.1.2ColumnkxtrapEntryTimeStampread-onlymandatoryThe time at which the trap occurred.
1.3.6.1.4.1.97.8.11.7.1.3ColumnkxtrapEntryTextread-onlymandatoryA description of the trap.
1.3.6.1.4.1.97.8.11.7.1.4ColumnkxtrapEntryNumberread-onlymandatoryThe specific trap number, as specified in the TRAP PDU.
1.3.6.1.4.1.97.8.11.7.1.5ColumnkxtrapEntrySeverityread-onlymandatoryA user-definable severity, indicating the importance of the trap.
1.3.6.1.4.1.97.8.12Nodekxmirrorgroup
1.3.6.1.4.1.97.8.12.1ScalarkxmirrorModeread-writemandatoryTo turn off port mirroring, or turn on by specifying rx, tx, or (rxandtx) which is the type of data to be mirrored.
1.3.6.1.4.1.97.8.12.2ScalarkxmirrorDiagPortread-writemandatoryThis entry identifies the diagnostic port to which mirrored packet will be destined.
1.3.6.1.4.1.97.8.12.3ScalarkxmirrorTargetPortListsread-writemandatoryAn octet string specifies the list of ports to be mirrored. The first octet specifies ports 1-8 and the second 9-16.