MIB Viewer

CTC-FRM220-MIB

22050 objects
FRM220 NMC MIB FILE V2.57
Imported Objects
RFC-1215TRAP-TYPE
SNMPv2-CONFMODULE-COMPLIANCE NOTIFICATION-GROUP OBJECT-GROUP
SNMPv2-SMICounter32 enterprises Gauge32 Integer32 IpAddress mib-2 MODULE-IDENTITY NOTIFICATION-TYPE OBJECT-TYPE TimeTicks
SNMPv2-TCAutonomousType DisplayString PhysAddress RowStatus TestAndIncr TEXTUAL-CONVENTION TimeStamp TruthValue
OIDNameAccessStatusDescription
1.3.6.1.4.1.4756Nodectc
1.3.6.1.4.1.4756.20Identityfrm220read-writeFRM220 NMC MIB FILE V2.57
1.3.6.1.4.1.4756.20.1ScalarthisChassisIDread-onlycurrentThis chassis ID.
1.3.6.1.4.1.4756.20.2ScalarstackInread-onlycurrentChassis is stacked: 0:No 1:Yes
1.3.6.1.4.1.4756.20.3ScalarchassisNoread-onlycurrentNumber of chassis.
1.3.6.1.4.1.4756.20.4ScalarchassisTyperead-onlycurrentWhat kind of chassis is: 0:CH20 1:CH02 2:CH04 3:CH08 4:CH04A 5:CH02-SMT
1.3.6.1.4.1.4756.20.30TablesnmpTablenot-accessiblecurrentA list of snmp entries.
1.3.6.1.4.1.4756.20.30.1RowsnmpEntrynot-accessiblecurrentAn entry containing management information applicable to a particular chassis.
1.3.6.1.4.1.4756.20.30.1.1ColumnchassisIndexread-onlycurrentA unique value for each chassis.
1.3.6.1.4.1.4756.20.30.1.2Columnredundancyread-writecurrentFRM220 Card redundancy mode : 0:Disable 1:Enable
1.3.6.1.4.1.4756.20.30.1.3ColumnserialNumberread-onlycurrentSNMP card Serial Number
1.3.6.1.4.1.4756.20.30.1.4Columnalarm1Moderead-writecurrentAlarm 1 mode: 0:Disable 1:Active if any power fails (default) 2:Active if any user#1 definition is met 3:Force active for manual testing
1.3.6.1.4.1.4756.20.30.1.5Columnalarm2Moderead-writecurrentAlarm 2 mode: 0:Disable 1:Active if any fan fails (default) 2:Active if any user#2 definition is met 3:Force active for manual testing
1.3.6.1.4.1.4756.20.30.1.6Columnuser1Power1read-writecurrentUser definition #1 for Alarm 1: 0:No defined 1:Alarm 1 is active when power 1 is failure
1.3.6.1.4.1.4756.20.30.1.7Columnuser1Power2read-writecurrentUser definition #1 for Alarm 1: 0:No defined 1:Alarm 1 is active when power 2 is failure
1.3.6.1.4.1.4756.20.30.1.8Columnuser1Fan1read-writecurrentUser definition #1 for Alarm 1: 0:No defined 1:Alarm 1 is active when fan 1 is failure
1.3.6.1.4.1.4756.20.30.1.9Columnuser1Fan2read-writecurrentUser definition #1 for Alarm 1: 0:No defined 1:Alarm 1 is active when fan 2 is failure
1.3.6.1.4.1.4756.20.30.1.10Columnuser1UtpLinkDNLocalread-writecurrentUser definition #1 for Alarm 1: 0:No defined 1:Alarm 1 is active when Local Utp Link Down is failure
1.3.6.1.4.1.4756.20.30.1.11Columnuser1FxLinkDNLocalread-writecurrentUser definition #1 for Alarm 1: 0:No defined 1:Alarm 1 is active when Local Fx Link Down is failure
1.3.6.1.4.1.4756.20.30.1.12Columnuser1FEFLocalread-writecurrentUser definition #1 for Alarm 1: 0:No defined 1:Alarm 1 is active when FEF is failure
1.3.6.1.4.1.4756.20.30.1.13Columnuser1RemoPWRABLocalread-writecurrentUser definition #1 for Alarm 1: 0:No defined 1:Alarm 1 is active when Remote Power is failure
1.3.6.1.4.1.4756.20.30.1.14Columnuser1FxLinkDNRemoteread-writecurrentUser definition #1 for Alarm 1: 0:No defined 1:Alarm 1 is active when Remote Fx Link Down is failure
1.3.6.1.4.1.4756.20.30.1.15Columnuser1UtpLinkDNRemoteread-writecurrentUser definition #1 for Alarm 1: 0:No defined 1:Alarm 1 is active when Remote Utp Link Down is failure
1.3.6.1.4.1.4756.20.30.1.16Columnuser2Power1read-writecurrentUser definition #2 for Alarm 2: 0:No defined 1:Alarm 2 is active when power 1 is failure
1.3.6.1.4.1.4756.20.30.1.17Columnuser2Power2read-writecurrentUser definition #2 for Alarm 2: 0:No defined 1:Alarm 2 is active when power 2 is failure
1.3.6.1.4.1.4756.20.30.1.18Columnuser2Fan1read-writecurrentUser definition #2 for Alarm 2: 0:No defined 1:Alarm 2 is active when fan 1 is failure
1.3.6.1.4.1.4756.20.30.1.19Columnuser2Fan2read-writecurrentUser definition #2 for Alarm 2: 0:No defined 1:Alarm 2 is active when fan 2 is failure
1.3.6.1.4.1.4756.20.30.1.20Columnuser2UtpLinkDNLocalread-writecurrentUser definition #2 for Alarm 2: 0:No defined 1:Alarm 2 is active when Utp Link Down is failure
1.3.6.1.4.1.4756.20.30.1.21Columnuser2FxLinkDNLocalread-writecurrentUser definition #2 for Alarm 2: 0:No defined 1:Alarm 2 is active when Fx link Down is failure
1.3.6.1.4.1.4756.20.30.1.22Columnuser2FEFLocalread-writecurrentUser definition #2 for Alarm 2: 0:No defined 1:Alarm 2 is active when FEF is failure
1.3.6.1.4.1.4756.20.30.1.23Columnuser2RemoPWRABLocalread-writecurrentUser definition #2 for Alarm 2: 0:No defined 1:Alarm 2 is active when Remote Power is failure
1.3.6.1.4.1.4756.20.30.1.24Columnuser2FxLinkDNRemoteread-writecurrentUser definition #2 for Alarm 2: 0:No defined 1:Alarm 2 is active when Fx Link Down is failure
1.3.6.1.4.1.4756.20.30.1.25Columnuser2UtpLinkDNRemoteread-writecurrentUser definition #2 for Alarm 2: 0:No defined 1:Alarm 2 is active when Utp Link Down is failure
1.3.6.1.4.1.4756.20.30.1.26Columnuser1SignalLossLocalread-writecurrentUser definition #1 for Alarm 1: 0:No defined 1:Alarm 1 is active when Signal Loss is failure
1.3.6.1.4.1.4756.20.30.1.27Columnuser1SignalLossRemoteread-writecurrentUser definition #1 for Alarm 1: 0:No defined 1:Alarm 1 is active when Signal Loss is failure
1.3.6.1.4.1.4756.20.30.1.28Columnuser2SignalLossLocalread-writecurrentUser definition #2 for Alarm 2: 0:No defined 1:Alarm 2 is active when Signal Loss is failure
1.3.6.1.4.1.4756.20.30.1.29Columnuser2SignalLossRemoteread-writecurrentUser definition #2 for Alarm 2: 0:No defined 1:Alarm 2 is active when Signal Loss is failure
1.3.6.1.4.1.4756.20.30.1.30Columnremotedevicepollingread-writecurrentRemote Device Polling: (for chassis to chassis management) 0:Disable 1:Enable
1.3.6.1.4.1.4756.20.30.1.31Columnfan1Typeread-writecurrentfan 1 Type: 0:Normal 1:High
1.3.6.1.4.1.4756.20.30.1.32Columnfan2Typeread-writecurrentfan 2 Type: 0:Normal 1:High
1.3.6.1.4.1.4756.20.30.1.33Columnuser1SyncLossLocalread-writecurrentUser definition #1 for Alarm 1: 0:No defined 1:Alarm 1 is active when Sync Loss is failure
1.3.6.1.4.1.4756.20.30.1.34Columnuser1SyncLossRemoteread-writecurrentUser definition #1 for Alarm 1: 0:No defined 1:Alarm 1 is active when Sync Loss is failure
1.3.6.1.4.1.4756.20.30.1.35Columnuser2SyncLossLocalread-writecurrentUser definition #2 for Alarm 2: 0:No defined 1:Alarm 2 is active when Sync Loss is failure
1.3.6.1.4.1.4756.20.30.1.36Columnuser2SyncLossRemoteread-writecurrentUser definition #2 for Alarm 2: 0:No defined 1:Alarm 2 is active when Sync Loss is failure
1.3.6.1.4.1.4756.20.40TablechassisCH20Tablenot-accessiblecurrentA list of chassis entries.
1.3.6.1.4.1.4756.20.40.1RowchassisCH20Entrynot-accessiblecurrentAn entry containing management information applicable to a particular chassis.
1.3.6.1.4.1.4756.20.40.1.1ColumnchassisCH20IDread-onlycurrentChassis ID
1.3.6.1.4.1.4756.20.40.1.2ColumnsnmpHWVerread-onlycurrentSNMP hardware version x.xx
1.3.6.1.4.1.4756.20.40.1.3ColumnsnmpFWVerread-onlycurrentSNMP firmware version x.xx
1.3.6.1.4.1.4756.20.40.1.4Columnpower1Typeread-onlycurrentPower 1 type: 0:Empty 1:AC 2:DC48V 3:DC24V
1.3.6.1.4.1.4756.20.40.1.5Columnpower1Statusread-onlycurrentPower 1 status: 0:OK 1:Fail or empty
1.3.6.1.4.1.4756.20.40.1.6Columnpower2Typeread-onlycurrentPower 2 type: 0:Empty 1:AC 2:DC48V 3:DC24V
1.3.6.1.4.1.4756.20.40.1.7Columnpower2Statusread-onlycurrentPower 2 status: 0:OK 1:Fail or empty
1.3.6.1.4.1.4756.20.40.1.8Columnfan1RPMread-onlycurrentFan 1 RPM
1.3.6.1.4.1.4756.20.40.1.9Columnfan1Statusread-onlycurrentFan 1 status: 0:OK 1:Fail
1.3.6.1.4.1.4756.20.40.1.10Columnfan2RPMread-onlycurrentFan 2 RPM
1.3.6.1.4.1.4756.20.40.1.11Columnfan2Statusread-onlycurrentFan 2 status: 0:OK 1:Fail or empty
1.3.6.1.4.1.4756.20.40.1.12Columnalarm1Statusread-onlycurrentAlarm 1 status: 0:Inactive 1:Active
1.3.6.1.4.1.4756.20.40.1.13Columnalarm2Statusread-onlycurrentAlarm 2 status: 0:Inactive 1:Active
1.3.6.1.4.1.4756.20.40.1.14ColumntimeServerIPread-writecurrentTime server IP address.
1.3.6.1.4.1.4756.20.40.1.15ColumntimeZoneread-writecurrentTime zone hh:mm.
1.3.6.1.4.1.4756.20.40.1.16ColumnsyncTimeread-writecurrent1:Do synchronise time
1.3.6.1.4.1.4756.20.40.1.17ColumnautoRecvTimeread-writecurrent0:Disable auto recieve time at startup 1:Enable auto recieve time at startup
1.3.6.1.4.1.4756.20.40.1.18ColumncurDateTimeread-writecurrentSet date and time of system
1.3.6.1.4.1.4756.20.41NodechassisCH08
1.3.6.1.4.1.4756.20.41.1ScalarsnmpHWVerCH08read-onlycurrentSNMP hardware version x.xx
1.3.6.1.4.1.4756.20.41.2ScalarsnmpFWVerCH08read-onlycurrentSNMP firmware version x.xx
1.3.6.1.4.1.4756.20.41.3Scalarpower1TypeCH08read-onlycurrentPower 1 type: 0:Empty 1:AC 2:DC48V 3:DC24V
1.3.6.1.4.1.4756.20.41.4Scalarpower1StatusCH08read-onlycurrentPower 1 status: 0:OK 1:Fail
1.3.6.1.4.1.4756.20.41.5Scalarpower2TypeCH08read-onlycurrentPower 2 type: 0:Empty 1:AC 2:DC48V 3:DC24V
1.3.6.1.4.1.4756.20.41.6Scalarpower2StatusCH08read-onlycurrentPower 2 status: 0:OK 1:Fail
1.3.6.1.4.1.4756.20.41.7Scalarfan1aRPMCH08read-onlycurrentFan 1a RPM
1.3.6.1.4.1.4756.20.41.8Scalarfan1aStatusCH08read-onlycurrentFan 1a status: 0:OK 1:Fail
1.3.6.1.4.1.4756.20.41.9Scalarfan1bRPMCH08read-onlycurrentFan 1b RPM
1.3.6.1.4.1.4756.20.41.10Scalarfan1bStatusCH08read-onlycurrentFan 1b status: 0:OK 1:Fail
1.3.6.1.4.1.4756.20.41.11Scalarfan2aRPMCH08read-onlycurrentFan 2a RPM
1.3.6.1.4.1.4756.20.41.12Scalarfan2aStatusCH08read-onlycurrentFan 2a status: 0:OK 1:Fail
1.3.6.1.4.1.4756.20.41.13Scalarfan2bRPMCH08read-onlycurrentFan 2b RPM
1.3.6.1.4.1.4756.20.41.14Scalarfan2bStatusCH08read-onlycurrentFan 2b status: 0:OK 1:Fail
1.3.6.1.4.1.4756.20.41.15Scalaralarm1StatusCH08read-onlycurrentAlarm 1 status: 0:Inactive 1:Active
1.3.6.1.4.1.4756.20.41.16Scalaralarm2StatusCH08read-onlycurrentAlarm 2 status: 0:Inactive 1:Active
1.3.6.1.4.1.4756.20.41.17ScalartimeServerIPCH08read-writecurrentTime server IP address.
1.3.6.1.4.1.4756.20.41.18ScalartimeZoneCH08read-writecurrentTime zone hh:mm.
1.3.6.1.4.1.4756.20.41.19ScalarsyncTimeCH08read-writecurrent1:Do synchronise time
1.3.6.1.4.1.4756.20.41.20ScalarautoRecvTimeCH08read-writecurrent0:Disable auto recieve time at startup 1:Enable auto recieve time at startup
1.3.6.1.4.1.4756.20.41.21ScalarcurDateTimeCH08read-writecurrentSet date and time of system
1.3.6.1.4.1.4756.20.42NodechassisCH04A
1.3.6.1.4.1.4756.20.42.1ScalarsnmpHWVerCH04Aread-onlycurrentSNMP hardware version x.xx
1.3.6.1.4.1.4756.20.42.2ScalarsnmpFWVerCH04Aread-onlycurrentSNMP firmware version x.xx
1.3.6.1.4.1.4756.20.42.3Scalarpower1StatusCH04Aread-onlycurrentPower 1 status: 0:OK 1:Fail
1.3.6.1.4.1.4756.20.42.4Scalarpower2StatusCH04Aread-onlycurrentPower 2 status: 0:OK 1:Fail
1.3.6.1.4.1.4756.20.42.5Scalaralarm1StatusCH04Aread-onlycurrentAlarm 1 status: 0:Inactive 1:Active
1.3.6.1.4.1.4756.20.42.6Scalaralarm2StatusCH04Aread-onlycurrentAlarm 2 status: 0:Inactive 1:Active
1.3.6.1.4.1.4756.20.42.7ScalartimeServerIPCH04Aread-writecurrentTime server IP address.
1.3.6.1.4.1.4756.20.42.8ScalartimeZoneCH04Aread-writecurrentTime zone hh:mm.
1.3.6.1.4.1.4756.20.42.9ScalarsyncTimeCH04Aread-writecurrent1:Do synchronise time
1.3.6.1.4.1.4756.20.42.10ScalarautoRecvTimeCH04Aread-writecurrent0:Disable auto recieve time at startup 1:Enable auto recieve time at startup
1.3.6.1.4.1.4756.20.42.11ScalarcurDateTimeCH04Aread-writecurrentSet date and time of system
1.3.6.1.4.1.4756.20.43NodechassisCH02SMT
1.3.6.1.4.1.4756.20.43.1ScalarsnmpHWVerCH02SMTread-onlycurrentFRM220-CH02-SMT Hardware version x.x.
1.3.6.1.4.1.4756.20.43.2ScalarsnmpFWVerCH02SMTread-onlycurrentFRM220-CH02-SMT Farmware version x.x.
1.3.6.1.4.1.4756.20.43.3Scalarpower1TypeCH02SMTread-onlycurrentFRM220-CH02-SMT Power 1 Type.
1.3.6.1.4.1.4756.20.43.4Scalarpower2TypeCH02SMTread-onlycurrentFRM220-CH02-SMT Power 2 Type.
1.3.6.1.4.1.4756.20.43.5Scalarpower1StatusCH02SMTread-onlycurrentFRM220-CH02-SMT Power 1 Status.
1.3.6.1.4.1.4756.20.43.6Scalarpower2StatusCH02SMTread-onlycurrentFRM220-CH02-SMT Power 2 Status.
1.3.6.1.4.1.4756.20.43.7Scalarpower1VoltCH02SMTread-onlycurrentFRM220-CH02-SMT Power 1 Voltage (V).
1.3.6.1.4.1.4756.20.43.8Scalarpower2VoltCH02SMTread-onlycurrentFRM220-CH02-SMT Power 2 Voltage (V).
1.3.6.1.4.1.4756.20.43.9Scalarpower1CurrCH02SMTread-onlycurrentFRM220-CH02-SMT Power 1 Current (A).
1.3.6.1.4.1.4756.20.43.10Scalarpower2CurrCH02SMTread-onlycurrentFRM220-CH02-SMT Power 2 Current (A).
1.3.6.1.4.1.4756.20.43.11Scalarfan1RPMCH02SMTread-onlycurrentFRM220-CH02-SMT Fan 1 Revolution Per Minute.
1.3.6.1.4.1.4756.20.43.12Scalarfan2RPMCH02SMTread-onlycurrentFRM220-CH02-SMT Fan 2 Revolution Per Minute.
1.3.6.1.4.1.4756.20.43.13Scalarfan1StatusCH02SMTread-onlycurrentFRM220-CH02-SMT Fan 1 Status.
1.3.6.1.4.1.4756.20.43.14Scalarfan2StatusCH02SMTread-onlycurrentFRM220-CH02-SMT Fan 2 Status.
1.3.6.1.4.1.4756.20.43.15Scalaralarm1StatusCH02SMTread-onlycurrentAlarm 1 status: 0:Inactive 1:Active
1.3.6.1.4.1.4756.20.43.16Scalaralarm2StatusCH02SMTread-onlycurrentAlarm 1 status: 0:Inactive 1:Active
1.3.6.1.4.1.4756.20.43.17ScalarfanCtrlCH02SMTread-writecurrentSet FRM220-CH02-SMT Fan Control.
1.3.6.1.4.1.4756.20.43.18ScalartimeServerIPCH02SMTread-writecurrentTime server IP address.
1.3.6.1.4.1.4756.20.43.19ScalartimeZoneCH02SMTread-writecurrentTime zone hh:mm.
1.3.6.1.4.1.4756.20.43.20ScalarsyncTimeCH02SMTread-writecurrent1:Do synchronise time
1.3.6.1.4.1.4756.20.43.21ScalarautoRecvTimeCH02SMTread-writecurrent0:Disable auto recieve time at startup 1:Enable auto recieve time at startup
1.3.6.1.4.1.4756.20.43.22ScalarcurDateTimeCH02SMTread-writecurrentSet date and time of system
1.3.6.1.4.1.4756.20.50TablelocalSlotTablenot-accessiblecurrentA list of local slot entries. The number of local slot entries is 20.
1.3.6.1.4.1.4756.20.50.1RowlocalSlotEntrynot-accessiblecurrentAn entry containing management information applicable to a particular local slot.
1.3.6.1.4.1.4756.20.50.1.1ColumnlocalChassisIndexread-onlycurrentA unique value for each local chassis. It starts from 0 to 9 contiguously.
1.3.6.1.4.1.4756.20.50.1.2ColumnlocalSlotIndexread-onlycurrentA unique value for each local slot. It starts from 1 to 20 contiguously.
1.3.6.1.4.1.4756.20.50.1.3ColumnlocalCardTyperead-onlycurrentLocal card type: 0:Empty 1:Unknown 2:SNMP 3:FRM200-10/100i 4:FMC-10/100i 5:FRM220-FXO/FXS 6:FRM220-Serial 7:FRM220-Data 8:FRM220-10/100AS-2 9:FRM220-10/100A 10…
1.3.6.1.4.1.4756.20.50.1.4ColumnlocalCardNameread-onlycurrentLocal card product name.
1.3.6.1.4.1.4756.20.50.1.5ColumnlocalCardSerialNumberread-onlycurrentLocal card inventory.
1.3.6.1.4.1.4756.20.51TableremoteSlotTablenot-accessiblecurrentA list of remote slot entries. The number of remote slot entries is 20.
1.3.6.1.4.1.4756.20.51.1RowremoteSlotEntrynot-accessiblecurrentAn entry containing management information applicable to a particular remote slot.
1.3.6.1.4.1.4756.20.51.1.1ColumnremoteChassisIndexread-onlycurrentA unique value for each remote chassis. It starts from 0 to 9 contiguously.
1.3.6.1.4.1.4756.20.51.1.2ColumnremoteSlotIndexread-onlycurrentA unique value for each remote slot. It starts from 1 to 20 contiguously.
1.3.6.1.4.1.4756.20.51.1.3ColumnremoteCardTyperead-onlycurrentRemote card type: 0:Empty 1:Unknown 2:SNMP 3:FRM200-10/100I 4:FMC-10/100I 5:FRM220-FXO/FXS 6:FRM220-SERIAL 7:FRM220-DATAPORT 8:FRM220-10/100AS-2 9:FRM220-10/10…
1.3.6.1.4.1.4756.20.51.1.4ColumnremoteCardNameread-onlycurrentRemote card product name.
1.3.6.1.4.1.4756.20.51.1.5ColumnremoteCardSerialNumberread-onlycurrentRemote card inventory.
1.3.6.1.4.1.4756.20.52TableremoteBSlotTablenot-accessiblecurrentA list of remote B slot entries. The number of remote slot entries is 20.
1.3.6.1.4.1.4756.20.52.1RowremoteBSlotEntrynot-accessiblecurrentAn entry containing management information applicable to a particular remote B slot.
1.3.6.1.4.1.4756.20.52.1.1ColumnremoteBChassisIndexread-onlycurrentA unique value for each remote B chassis. It starts from 0 to 9 contiguously.
1.3.6.1.4.1.4756.20.52.1.2ColumnremoteBSlotIndexread-onlycurrentA unique value for each remote B slot. It starts from 1 to 20 contiguously.
1.3.6.1.4.1.4756.20.52.1.3ColumnremoteBCardTyperead-onlycurrentRemote B card type: 0:Empty 1:Unknown 2:SNMP 3:FRM200-10/100I 4:FMC-10/100I 5:FRM220-FXO/FXS 6:FRM220-SERIAL 7:FRM220-DATAPORT 8:FRM220-10/100AS 9:FRM220-10/10…
1.3.6.1.4.1.4756.20.52.1.4ColumnremoteBCardNameread-onlycurrentRemote B card product name.
1.3.6.1.4.1.4756.20.52.1.5ColumnremoteBCardSerialNumberread-onlycurrentRemote B card inventory.
1.3.6.1.4.1.4756.20.59TableupgradeTablenot-accessiblecurrentA list of upgrade entries.
1.3.6.1.4.1.4756.20.59.1RowupgradeEntrynot-accessiblecurrentAn entry containing management information applicable to a particular upgrade status.
1.3.6.1.4.1.4756.20.59.1.1ColumnupgradeChassisIndexread-onlycurrentA unique value for each chassis.
1.3.6.1.4.1.4756.20.59.1.2ColumntftpServerIPread-writecurrentTFTP server IP address.
1.3.6.1.4.1.4756.20.59.1.3ColumnfileSystemFileNameread-writecurrentFile System File Name The length of Filename is limited to 20 characters.
1.3.6.1.4.1.4756.20.59.1.4ColumnflashfileSystemread-writecurrent1:Do Flash NMC File System
1.3.6.1.4.1.4756.20.59.1.5ColumnupgradeLineCardTyperead-writecurrentUpgrade Line Card - Card Type: 0:None 1:FRM220-10/100i 2:FRM220-1000EAS-X-1 3:FRM220A-1000EAS-X 4:FRM220-1000EAS-X-2F 5:FRM220-100AS-1 6:FRM220-FOM01 7:FRM220-…
1.3.6.1.4.1.4756.20.59.1.6ColumnupgradeLineCardSlotread-writecurrentUpgrade Line Card - Slot: 0:All 2:Slot 2 3:Slot 3 4:Slot 4 5:Slot 5 6:Slot 6 7:Slot 7 8:Slot 8 9:Slot 9 10:Slot 10 11:Slot 11 12:Slot 12 13:Slot 13 14:Slot 14 …
1.3.6.1.4.1.4756.20.59.1.7ColumnupgradeLineCardSideread-writecurrentUpgrade Line Card - Side 0:Local 1:Remote (A) 2:Remote B
1.3.6.1.4.1.4756.20.59.1.8ColumnupgradeLineCardFileNameread-writecurrentUpgrade Line Card - File Name The length of Filename is limited to 20 characters.
1.3.6.1.4.1.4756.20.59.1.9ColumnupgradeLineCardread-writecurrent1:Do Upgrade Line Card For upgrading local side 1000EAS/X,1000EAS/X-1,1000EAS/X-2F,100AS-1 F/W: During this processing, the other NIC card types will NOT be mo…
1.3.6.1.4.1.4756.20.59.1.10ColumnupgradeStatusread-onlycurrentUpgrade status
1.3.6.1.4.1.4756.20.60Nodef100ILocalCards
1.3.6.1.4.1.4756.20.60.20Tablef100ILocalTablenot-accessiblecurrentA list of local FRM220-10/100I card entries. The number of entries is f100I-No-L.
1.3.6.1.4.1.4756.20.60.20.1Rowf100ILocalEntrynot-accessiblecurrentAn entry containing management information applicable to a particular local FRM220-10/100I card.
1.3.6.1.4.1.4756.20.60.20.1.1Columnf100IChassisIndexLocalread-onlycurrentA unique value for each local card. It is the chassis location number.
1.3.6.1.4.1.4756.20.60.20.1.2Columnf100ISlotIndexLocalread-onlycurrentA unique value for each local card. It is the slot location number.
1.3.6.1.4.1.4756.20.60.20.1.3Columnf100ICardHWVerLocalread-onlycurrentLocal FRM220-10/100I card hardware version x.xxx
1.3.6.1.4.1.4756.20.60.20.1.4Columnf100ICardFWVerLocalread-onlycurrentLocal FRM220-10/100I card firmware version x.xxx
1.3.6.1.4.1.4756.20.60.20.1.5Columnf100ICardCPLDVerLocalread-onlycurrentLocal FRM220-10/100I card CPLD version x.xxx
1.3.6.1.4.1.4756.20.60.20.1.6Columnf100ICardFPGAVerLocalread-onlycurrentLocal FRM220-10/100I card FPGA version x.xxx
1.3.6.1.4.1.4756.20.60.20.1.7Columnf100IPortActiveLocalread-writecurrentLocal FRM220-10/100I card active: 0:Inactive 1:Active
1.3.6.1.4.1.4756.20.60.20.1.8Columnf100IInBandManagLocalread-writecurrentLocal FRM220-10/100I card manages remote: 0:Disable 1:Enable
1.3.6.1.4.1.4756.20.60.20.1.9Columnf100IUtpLinkLocalread-onlycurrentLocal FRM220-10/100I card UTP link status: 0:Down 1:Up
1.3.6.1.4.1.4756.20.60.20.1.10Columnf100IUtpRxActLocalread-onlycurrentLocal FRM220-10/100I card UTP receive active status: 0:Off 1:On
1.3.6.1.4.1.4756.20.60.20.1.11Columnf100IUtpNegoLocalread-writecurrentLocal FRM220-10/100I card UTP negotiation status: 0:Manual 1:Auto
1.3.6.1.4.1.4756.20.60.20.1.12Columnf100IUtpSpeedLocalread-writecurrentLocal FRM220-10/100I card UTP speed: 0:10MHz 1:100MHz
1.3.6.1.4.1.4756.20.60.20.1.13Columnf100IUtpDuplexLocalread-writecurrentLocal FRM220-10/100I card UTP duplex: 0:Half duplex mode 1:Full duplex mode
1.3.6.1.4.1.4756.20.60.20.1.14Columnf100IUtpSpeedStatusLocalread-onlycurrentLocal FRM220-10/100I card UTP speed status: 0:10MHz 1:100MHz
1.3.6.1.4.1.4756.20.60.20.1.15Columnf100IUtpDuplexStatusLocalread-onlycurrentLocal FRM220-10/100I card UTP duplex status: 0:Half duplex mode 1:Full duplex mode
1.3.6.1.4.1.4756.20.60.20.1.16Columnf100IUtpRxByteLocalread-onlycurrentLocal FRM220-10/100I card UTP-in octet counter
1.3.6.1.4.1.4756.20.60.20.1.17Columnf100IUtpTxByteLocalread-onlycurrentLocal FRM220-10/100I card UTP-out octet counter
1.3.6.1.4.1.4756.20.60.20.1.18Columnf100IUtpFnlRxByteLocalread-onlycurrentLocal FRM220-10/100I card UTP-in final octets
1.3.6.1.4.1.4756.20.60.20.1.19Columnf100IUtpFnlTxByteLocalread-onlycurrentLocal FRM220-10/100I card UTP-out final octets
1.3.6.1.4.1.4756.20.60.20.1.20Columnf100IFxLinkLocalread-onlycurrentLocal FRM220-10/100I card fiber link status: 0:Down 1:Up
1.3.6.1.4.1.4756.20.60.20.1.21Columnf100IFxRxActLocalread-onlycurrentLocal FRM220-10/100I card fiber receiver active status: 0:Off 1:On
1.3.6.1.4.1.4756.20.60.20.1.22Columnf100IFxFEFLocalread-onlycurrentLocal FRM220-10/100I card fiber detected Far End Fault: 0:Off 1:Detected
1.3.6.1.4.1.4756.20.60.20.1.23Columnf100IFxLBTestLocalread-writecurrentForce remote FRM220-10/100I card to do fiber LoopBack testing: 0:Off 1:Action
1.3.6.1.4.1.4756.20.60.20.1.24Columnf100IFxLBStatusLocalread-onlycurrentLocal FRM220-10/100I card fiber LoopBack testing status: 0:Off 1:Ok 2:Fail
1.3.6.1.4.1.4756.20.60.20.1.25Columnf100IFxRemoPWRAbLocalread-onlycurrentLocal FRM220-10/100I card fiber Remote Power status: 0:Abnormal 1:OK
1.3.6.1.4.1.4756.20.60.20.1.26Columnf100IIrlModeLocalread-writecurrentLocal FRM220-10/100I card Ingress Rate Limit mode: 0:No limit 1:n x 32K 2:n x 512K
1.3.6.1.4.1.4756.20.60.20.1.27Columnf100IIrlMultLocalread-writecurrentLocal FRM220-10/100I card Ingress Rate Limit multiple: When the irlMode-L is n x 32K mode, the irlMult-L should be the value between 0 to 255; When the irlMode…
1.3.6.1.4.1.4756.20.60.20.1.28Columnf100IErlModeLocalread-writecurrentLocal FRM220-10/100I card Egress Rate Limit mode: 0:No limit 1:n x 32K 2:n x 512K
1.3.6.1.4.1.4756.20.60.20.1.29Columnf100IErlMultLocalread-writecurrentLocal FRM220-10/100I card Egress Rate Limit multiple: When the erlMode-L is n x 32K mode, the erlMult-L should be the value between 0 to 255; When the erlMode-…
1.3.6.1.4.1.4756.20.60.20.1.30Columnf100IFxRxByteLocalread-onlycurrentLocal FRM220-10/100I card FX-in octet counter
1.3.6.1.4.1.4756.20.60.20.1.31Columnf100IFxTxByteLocalread-onlycurrentLocal FRM220-10/100I card FX-out octet counter
1.3.6.1.4.1.4756.20.60.20.1.32Columnf100IFxFnlRxByteLocalread-onlycurrentLocal FRM220-10/100I card FX-in final octets
1.3.6.1.4.1.4756.20.60.20.1.33Columnf100IFxFnlTxByteLocalread-onlycurrentLocal FRM220-10/100I card FX-out final octets
1.3.6.1.4.1.4756.20.60.20.1.34Columnf100IPortResetLocalread-writecurrentForce local FRM220-10/100I card to reset mode: 0:Off 1:Action
1.3.6.1.4.1.4756.20.60.20.1.35Columnf100IClrCountersLocalread-writecurrentForce local FRM220-10/100I card to clear all counters: 0:Off 1:Action
1.3.6.1.4.1.4756.20.60.20.1.36Columnf100IOpModeLocalread-writecurrentLocal FRM220-10/100I card operation mode: 0:Switch mode 1:Converter mode
1.3.6.1.4.1.4756.20.60.20.1.37Columnf100ILfpModeLocalread-writecurrentLocal FRM220-10/100I card Link Fault Pass-through mode: 0:Disable 1:Enable
1.3.6.1.4.1.4756.20.60.20.1.38Columnf100IAlsModeLocalread-writecurrentLocal FRM220-10/100I card Auto Laser Shutdown mode: 0:Disable 1:Enable
1.3.6.1.4.1.4756.20.60.20.1.39Columnf100ISendFHRLocalread-writecurrentLocal FRM220-10/100I card send Fiber Hardware Reset to remote: 0:No action 1:Action
1.3.6.1.4.1.4756.20.60.20.1.40Columnf100ISettoDefaultLocalread-writecurrentLocal FRM220-10/100I card Set to default: 0:No action 1:Action
1.3.6.1.4.1.4756.20.60.20.1.41Columnf100IFxDDLocalread-onlycurrentLocal FRM220-10/100I card fiber Digital Diagnostic function: 0:No 1:Yes
1.3.6.1.4.1.4756.20.60.20.1.42Columnf100IDDVendorLocalread-onlycurrentLocal FRM220-10/100I card fiber D/D information: Vendor name
1.3.6.1.4.1.4756.20.60.20.1.43Columnf100IDDPartNoLocalread-onlycurrentLocal FRM220-10/100I card fiber D/D information: Vendor part number
1.3.6.1.4.1.4756.20.60.20.1.44Columnf100IDDFiberTypeLocalread-onlycurrentLocal FRM220-10/100I card fiber D/D information: Fiber Type
1.3.6.1.4.1.4756.20.60.20.1.45Columnf100IDDWaveLenLocalread-onlycurrentLocal FRM220-10/100I card fiber D/D information: Wave length
1.3.6.1.4.1.4756.20.60.20.1.46Columnf100IDDWaveLen2Localread-onlycurrentLocal FRM220-10/100I card fiber D/D information: Wave length 2
1.3.6.1.4.1.4756.20.60.20.1.47Columnf100IDDLinkLenLocalread-onlycurrentLocal FRM220-10/100I card fiber D/D information: Link length
1.3.6.1.4.1.4756.20.60.20.1.48Columnf100IDDLenUnitLocalread-onlycurrentLocal FRM220-10/100I card fiber D/D information: Length Unit
1.3.6.1.4.1.4756.20.60.20.1.49Columnf100IDDStatusLocalread-onlycurrentLocal FRM220-10/100I card fiber D/D information: Status Support
1.3.6.1.4.1.4756.20.60.20.1.50Columnf100IDDRxSensLocalread-onlycurrentLocal FRM220-10/100I card fiber D/D information: Rx Sensitivity
1.3.6.1.4.1.4756.20.60.20.1.51Columnf100IDDTxPWRLocalread-onlycurrentLocal FRM220-10/100I card fiber D/D information: Tx power
1.3.6.1.4.1.4756.20.60.20.1.52Columnf100IDDRxPWRLocalread-onlycurrentLocal FRM220-10/100I card fiber D/D information: Rx power
1.3.6.1.4.1.4756.20.60.20.1.53Columnf100IDDTempLocalread-onlycurrentLocal FRM220-10/100I card fiber D/D information: Temperature in degree C
1.3.6.1.4.1.4756.20.60.20.1.54Columnf100IDDPWRMarginLocalread-onlycurrentLocal FRM220-10/100I card fiber D/D information: Power margin
1.3.6.1.4.1.4756.20.60.20.1.55Columnf100IDDPWRLossLocalread-onlycurrentLocal FRM220-10/100I card fiber D/D information: Power loss
1.3.6.1.4.1.4756.20.60.20.1.56Columnf100IInfoR1SN1Localread-onlycurrentLocal FRM220-10/100I card INFORemoteOM S/N 1 information
1.3.6.1.4.1.4756.20.60.20.1.57Columnf100IInfoR1SN2Localread-onlycurrentLocal FRM220-10/100I card INFORemoteOM S/N 2 information
1.3.6.1.4.1.4756.20.61Nodef100IRemoteCards
1.3.6.1.4.1.4756.20.61.20Tablef100IRemoteTablenot-accessiblecurrentA list of remote FRM220-10/100I card entries. The number of entries is f100I-NoRemote.
1.3.6.1.4.1.4756.20.61.20.1Rowf100IRemoteEntrynot-accessiblecurrentAn entry containing management information applicable to a particular remote FRM220-10/100I card.
1.3.6.1.4.1.4756.20.61.20.1.1Columnf100IChassisIndexRemoteread-onlycurrentA unique value for each local card. It is the chassis location number.
1.3.6.1.4.1.4756.20.61.20.1.2Columnf100ISlotIndexRemoteread-onlycurrentA unique value for each remote card. It is the slot location number.
1.3.6.1.4.1.4756.20.61.20.1.3Columnf100ICardHWVerRemoteread-onlycurrentRemote FRM220-10/100I card hardware version x.xxx
1.3.6.1.4.1.4756.20.61.20.1.4Columnf100ICardFWVerRemoteread-onlycurrentRemote FRM220-10/100I card firmware version x.xxx
1.3.6.1.4.1.4756.20.61.20.1.5Columnf100ICardCPLDVerRemoteread-onlycurrentRemote FRM220-10/100I card CPLD version x.xxx
1.3.6.1.4.1.4756.20.61.20.1.6Columnf100ICardFPGAVerRemoteread-onlycurrentRemote FRM220-10/100I card FPGA version x.xxx
1.3.6.1.4.1.4756.20.61.20.1.7Columnf100IPortActiveRemoteread-onlycurrentRemote FRM220-10/100I card active: (It is read-only in remote side.) 0:Inactive 1:Active
1.3.6.1.4.1.4756.20.61.20.1.8Columnf100IInBandManagRemoteread-onlycurrent(Local only) FRM220-10/100I card manages remote: 0:Disable 1:Enable
1.3.6.1.4.1.4756.20.61.20.1.9Columnf100IUtpLinkRemoteread-onlycurrentRemote FRM220-10/100I card UTP link status: 0:Down 1:Up
1.3.6.1.4.1.4756.20.61.20.1.10Columnf100IUtpRxActRemoteread-onlycurrentRemote FRM220-10/100I card UTP receive active status: 0:Off 1:On
1.3.6.1.4.1.4756.20.61.20.1.11Columnf100IUtpNegoRemoteread-writecurrentRemote FRM220-10/100I card UTP negotiation status: 0:Manual 1:Auto
1.3.6.1.4.1.4756.20.61.20.1.12Columnf100IUtpSpeedRemoteread-writecurrentRemote FRM220-10/100I card UTP speed: 0:10MHz 1:100MHz
1.3.6.1.4.1.4756.20.61.20.1.13Columnf100IUtpDuplexRemoteread-writecurrentRemote FRM220-10/100I card UTP duplex: 0:Half duplex mode 1:Full duplex mode
1.3.6.1.4.1.4756.20.61.20.1.14Columnf100IUtpSpeedStatusRemoteread-onlycurrentRemote FRM220-10/100I card UTP speed status: 0:10MHz 1:100MHz
1.3.6.1.4.1.4756.20.61.20.1.15Columnf100IUtpDuplexStatusRemoteread-onlycurrentRemote FRM220-10/100I card UTP duplex status: 0:Half duplex mode 1:Full duplex mode
1.3.6.1.4.1.4756.20.61.20.1.16Columnf100IUtpRxByteRemoteread-onlycurrentRemote FRM220-10/100I card UTP-in octet counter
1.3.6.1.4.1.4756.20.61.20.1.17Columnf100IUtpTxByteRemoteread-onlycurrentRemote FRM220-10/100I card UTP-out octet counter
1.3.6.1.4.1.4756.20.61.20.1.18Columnf100IUtpFnlRxByteRemoteread-onlycurrentRemote FRM220-10/100I card UTP-in final octets
1.3.6.1.4.1.4756.20.61.20.1.19Columnf100IUtpFnlTxByteRemoteread-onlycurrentRemote FRM220-10/100I card UTP-out final octets
1.3.6.1.4.1.4756.20.61.20.1.20Columnf100IFxLinkRemoteread-onlycurrentRemote FRM220-10/100I card fiber link status: 0:Down 1:Up
1.3.6.1.4.1.4756.20.61.20.1.21Columnf100IFxRxActRemoteread-onlycurrentRemote FRM220-10/100I card fiber receiver active status: 0:Off 1:On
1.3.6.1.4.1.4756.20.61.20.1.22Columnf100IFxFEFRemoteread-onlycurrentRemote FRM220-10/100I card fiber detected Far End Fault: 0:Off 1:Detected
1.3.6.1.4.1.4756.20.61.20.1.23Columnf100IFxLBTestRemoteread-writecurrentForce local FRM220-10/100I card to do fiber LoopBack testing: 0:Off 1:Action
1.3.6.1.4.1.4756.20.61.20.1.24Columnf100IFxLBStatusRemoteread-onlycurrentRemote FRM220-10/100I card fiber LoopBack testing status: 0:Off 1:Ok 2:Fail
1.3.6.1.4.1.4756.20.61.20.1.25Columnf100IFxRemoPWRAbRemoteread-onlycurrentRemote FRM220-10/100I card fiber Remote Power status: 0:Abnormal 1:OK
1.3.6.1.4.1.4756.20.61.20.1.26Columnf100IIrlModeRemoteread-writecurrentRemote FRM220-10/100I card Ingress Rate Limit mode: 0:No limit 1:n x 32K 2:n x 512K
1.3.6.1.4.1.4756.20.61.20.1.27Columnf100IIrlMultRemoteread-writecurrentRemote FRM220-10/100I card Ingress Rate Limit multiple: When the irlModeRemote is n x 32K mode, the irlMultRemote should be the value between 0 to 255; When th…
1.3.6.1.4.1.4756.20.61.20.1.28Columnf100IErlModeRemoteread-writecurrentRemote FRM220-10/100I card Egress Rate Limit mode: 0:No limit 1:n x 32K 2:n x 512K
1.3.6.1.4.1.4756.20.61.20.1.29Columnf100IErlMultRemoteread-writecurrentRemote FRM220-10/100I card Egress Rate Limit multiple: When the erlModeRemote is n x 32K mode, the erlMultRemote should be the value between 0 to 255; When the…
1.3.6.1.4.1.4756.20.61.20.1.30Columnf100IFxRxByteRemoteread-onlycurrentRemote FRM220-10/100I card FX-in octet counter
1.3.6.1.4.1.4756.20.61.20.1.31Columnf100IFxTxByteRemoteread-onlycurrentRemote FRM220-10/100I card FX-out octet counter
1.3.6.1.4.1.4756.20.61.20.1.32Columnf100IFxFnlRxByteRemoteread-onlycurrentRemote FRM220-10/100I card FX-in final octets
1.3.6.1.4.1.4756.20.61.20.1.33Columnf100IFxFnlTxByteRemoteread-onlycurrentRemote FRM220-10/100I card FX-out final octets
1.3.6.1.4.1.4756.20.61.20.1.34Columnf100IPortResetRemoteread-writecurrentForce remote FRM220-10/100I card to reset mode: 0:Off 1:Action
1.3.6.1.4.1.4756.20.61.20.1.35Columnf100IClrCountersRemoteread-writecurrentForce remote FRM220-10/100I card to clear all counters: 0:Off 1:Action
1.3.6.1.4.1.4756.20.61.20.1.36Columnf100IOpModeRemoteread-writecurrentRemote FRM220-10/100I card operation mode: 0:Switch mode 1:Converter mode
1.3.6.1.4.1.4756.20.61.20.1.37Columnf100ILfpModeRemoteread-writecurrentRemote FRM220-10/100I card Link Fault Pass-through mode: 0:Disable 1:Enable
1.3.6.1.4.1.4756.20.61.20.1.38Columnf100IAlsModeRemoteread-writecurrentRemote FRM220-10/100I card Auto Laser Shutdown mode: 0:Disable 1:Enable
1.3.6.1.4.1.4756.20.61.20.1.39Columnf100IFhrModeRemoteread-writecurrentRemote FRM220-10/100I card accepts Fiber Hardware Reset mode: 0:Disable 1:Enable
1.3.6.1.4.1.4756.20.61.20.1.40Columnf100ISettoDefaultRemoteread-writecurrentRemote FRM220-10/100I card Set to default: 0:Disable 1:Enable
1.3.6.1.4.1.4756.20.61.20.1.41Columnf100IFxDDRemoteread-onlycurrentRemote FRM220-10/100I card fiber Digital Diagnostic function: 0:No 1:Yes
1.3.6.1.4.1.4756.20.61.20.1.42Columnf100IDDVendorRemoteread-onlycurrentRemote FRM220-10/100I card fiber D/D information: Vendor name
1.3.6.1.4.1.4756.20.61.20.1.43Columnf100IDDPartNoRemoteread-onlycurrentRemote FRM220-10/100I card fiber D/D information: Vendor part number
1.3.6.1.4.1.4756.20.61.20.1.44Columnf100IDDFiberTypeRemoteread-onlycurrentRemote FRM220-10/100I card fiber D/D information: Fiber Type
1.3.6.1.4.1.4756.20.61.20.1.45Columnf100IDDWaveLenRemoteread-onlycurrentRemote FRM220-10/100I card fiber D/D information: Wave length
1.3.6.1.4.1.4756.20.61.20.1.46Columnf100IDDWaveLen2Remoteread-onlycurrentRemote FRM220-10/100I card fiber D/D information: Wave length 2
1.3.6.1.4.1.4756.20.61.20.1.47Columnf100IDDLinkLenRemoteread-onlycurrentRemote FRM220-10/100I card fiber D/D information: Link length
1.3.6.1.4.1.4756.20.61.20.1.48Columnf100IDDLenUnitRemoteread-onlycurrentRemote FRM220-10/100I card fiber D/D information: Length Unit
1.3.6.1.4.1.4756.20.61.20.1.49Columnf100IDDStatusRemoteread-onlycurrentRemote FRM220-10/100I card fiber D/D information: Status Support
1.3.6.1.4.1.4756.20.61.20.1.50Columnf100IDDRxSensRemoteread-onlycurrentRemote FRM220-10/100I card fiber D/D information: Rx Sensitivity
1.3.6.1.4.1.4756.20.61.20.1.51Columnf100IDDTxPWRRemoteread-onlycurrentRemote FRM220-10/100I card fiber D/D information: Tx power
1.3.6.1.4.1.4756.20.61.20.1.52Columnf100IDDRxPWRRemoteread-onlycurrentRemote FRM220-10/100I card fiber D/D information: Rx power
1.3.6.1.4.1.4756.20.61.20.1.53Columnf100IDDTempRemoteread-onlycurrentRemote FRM220-10/100I card fiber D/D information: Temperature in degree C
1.3.6.1.4.1.4756.20.61.20.1.54Columnf100IDDPWRMarginRemoteread-onlycurrentRemote FRM220-10/100I card fiber D/D information: Power margin
1.3.6.1.4.1.4756.20.61.20.1.55Columnf100IDDPWRLossRemoteread-onlycurrentRemote FRM220-10/100I card fiber D/D information: Power loss
1.3.6.1.4.1.4756.20.61.20.1.56Columnf100IInfoR1SN1Remoteread-onlycurrentRemote FRM220-10/100I card INFORemoteOM S/N 1 information
1.3.6.1.4.1.4756.20.61.20.1.57Columnf100IInfoR1SN2Remoteread-onlycurrentRemote FRM220-10/100I card INFORemoteOM S/N 2 information
1.3.6.1.4.1.4756.20.62Nodef100IRemoteBCards
1.3.6.1.4.1.4756.20.62.20Tablef100IRemoteBTablenot-accessiblecurrentA list of remote B FRM220-10/100I card entries. The number of entries is f100I-NoRemote.
1.3.6.1.4.1.4756.20.62.20.1Rowf100IRemoteBEntrynot-accessiblecurrentAn entry containing management information applicable to a particular remote FRM220-10/100I B card.
1.3.6.1.4.1.4756.20.62.20.1.1Columnf100IChassisIndexRemoteBread-onlycurrentA unique value for each local card. It is the chassis location number.
1.3.6.1.4.1.4756.20.62.20.1.2Columnf100ISlotIndexRemoteBread-onlycurrentA unique value for each remote card. It is the slot location number.
1.3.6.1.4.1.4756.20.62.20.1.3Columnf100ICardHWVerRemoteBread-onlycurrentRemoteB FRM220-10/100I card hardware version x.xxx
1.3.6.1.4.1.4756.20.62.20.1.4Columnf100ICardFWVerRemoteBread-onlycurrentRemoteB FRM220-10/100I card firmware version x.xxx
1.3.6.1.4.1.4756.20.62.20.1.5Columnf100ICardCPLDVerRemoteBread-onlycurrentRemoteB FRM220-10/100I card CPLD version x.xxx
1.3.6.1.4.1.4756.20.62.20.1.6Columnf100ICardFPGAVerRemoteBread-onlycurrentRemoteB FRM220-10/100I card FPGA version x.xxx
1.3.6.1.4.1.4756.20.62.20.1.7Columnf100IPortActiveRemoteBread-onlycurrentRemoteB FRM220-10/100I card active: (It is read-only in remote side.) 0:Inactive 1:Active
1.3.6.1.4.1.4756.20.62.20.1.8Columnf100IInBandManagRemoteBread-onlycurrent(Local only) FRM220-10/100I card manages remote: 0:Disable 1:Enable
1.3.6.1.4.1.4756.20.62.20.1.9Columnf100IUtpLinkRemoteBread-onlycurrentRemoteB FRM220-10/100I card UTP link status: 0:Down 1:Up
1.3.6.1.4.1.4756.20.62.20.1.10Columnf100IUtpRxActRemoteBread-onlycurrentRemoteB FRM220-10/100I card UTP receive active status: 0:Off 1:On
1.3.6.1.4.1.4756.20.62.20.1.11Columnf100IUtpNegoRemoteBread-writecurrentRemoteB FRM220-10/100I card UTP negotiation status: 0:Manual 1:Auto
1.3.6.1.4.1.4756.20.62.20.1.12Columnf100IUtpSpeedRemoteBread-writecurrentRemoteB FRM220-10/100I card UTP speed: 0:10MHz 1:100MHz
1.3.6.1.4.1.4756.20.62.20.1.13Columnf100IUtpDuplexRemoteBread-writecurrentRemoteB FRM220-10/100I card UTP duplex: 0:Half duplex mode 1:Full duplex mode
1.3.6.1.4.1.4756.20.62.20.1.14Columnf100IUtpSpeedStatusRemoteBread-onlycurrentRemoteB FRM220-10/100I card UTP speed status: 0:10MHz 1:100MHz
1.3.6.1.4.1.4756.20.62.20.1.15Columnf100IUtpDuplexStatusRemoteBread-onlycurrentRemoteB FRM220-10/100I card UTP duplex status: 0:Half duplex mode 1:Full duplex mode
1.3.6.1.4.1.4756.20.62.20.1.16Columnf100IUtpRxByteRemoteBread-onlycurrentRemoteB FRM220-10/100I card UTP-in octet counter
1.3.6.1.4.1.4756.20.62.20.1.17Columnf100IUtpTxByteRemoteBread-onlycurrentRemoteB FRM220-10/100I card UTP-out octet counter
1.3.6.1.4.1.4756.20.62.20.1.18Columnf100IUtpFnlRxByteRemoteBread-onlycurrentRemoteB FRM220-10/100I card UTP-in final octets
1.3.6.1.4.1.4756.20.62.20.1.19Columnf100IUtpFnlTxByteRemoteBread-onlycurrentRemoteB FRM220-10/100I card UTP-out final octets
1.3.6.1.4.1.4756.20.62.20.1.20Columnf100IFxLinkRemoteBread-onlycurrentRemoteB FRM220-10/100I card fiber link status: 0:Down 1:Up
1.3.6.1.4.1.4756.20.62.20.1.21Columnf100IFxRxActRemoteBread-onlycurrentRemoteB FRM220-10/100I card fiber receiver active status: 0:Off 1:On
1.3.6.1.4.1.4756.20.62.20.1.22Columnf100IFxFEFRemoteBread-onlycurrentRemoteB FRM220-10/100I card fiber detected Far End Fault: 0:Off 1:Detected
1.3.6.1.4.1.4756.20.62.20.1.23Columnf100IFxLBTestRemoteBread-writecurrentForce local FRM220-10/100I card to do fiber LoopBack testing: 0:Off 1:Action
1.3.6.1.4.1.4756.20.62.20.1.24Columnf100IFxLBStatusRemoteBread-onlycurrentRemoteB FRM220-10/100I card fiber LoopBack testing status: 0:Off 1:Ok 2:Fail
1.3.6.1.4.1.4756.20.62.20.1.25Columnf100IFxRemoPWRAbRemoteBread-onlycurrentRemoteB FRM220-10/100I card fiber RemoteB Power status: 0:Abnormal 1:OK
1.3.6.1.4.1.4756.20.62.20.1.26Columnf100IIrlModeRemoteBread-writecurrentRemoteB FRM220-10/100I card Ingress Rate Limit mode: 0:No limit 1:n x 32K 2:n x 512K
1.3.6.1.4.1.4756.20.62.20.1.27Columnf100IIrlMultRemoteBread-writecurrentRemoteB FRM220-10/100I card Ingress Rate Limit multiple: When the irlModeRemoteB is n x 32K mode, the irlMultRemoteB should be the value between 0 to 255; When…
1.3.6.1.4.1.4756.20.62.20.1.28Columnf100IErlModeRemoteBread-writecurrentRemoteB FRM220-10/100I card Egress Rate Limit mode: 0:No limit 1:n x 32K 2:n x 512K
1.3.6.1.4.1.4756.20.62.20.1.29Columnf100IErlMultRemoteBread-writecurrentRemoteB FRM220-10/100I card Egress Rate Limit multiple: When the erlModeRemoteB is n x 32K mode, the erlMultRemoteB should be the value between 0 to 255; When …
1.3.6.1.4.1.4756.20.62.20.1.30Columnf100IFxRxByteRemoteBread-onlycurrentRemoteB FRM220-10/100I card FX-in octet counter
1.3.6.1.4.1.4756.20.62.20.1.31Columnf100IFxTxByteRemoteBread-onlycurrentRemoteB FRM220-10/100I card FX-out octet counter
1.3.6.1.4.1.4756.20.62.20.1.32Columnf100IFxFnlRxByteRemoteBread-onlycurrentRemoteB FRM220-10/100I card FX-in final octets
1.3.6.1.4.1.4756.20.62.20.1.33Columnf100IFxFnlTxByteRemoteBread-onlycurrentRemoteB FRM220-10/100I card FX-out final octets
1.3.6.1.4.1.4756.20.62.20.1.34Columnf100IPortResetRemoteBread-writecurrentForce remote FRM220-10/100I card to reset mode: 0:Off 1:Action
1.3.6.1.4.1.4756.20.62.20.1.35Columnf100IClrCountersRemoteBread-writecurrentForce remote FRM220-10/100I card to clear all counters: 0:Off 1:Action
1.3.6.1.4.1.4756.20.62.20.1.36Columnf100IOpModeRemoteBread-writecurrentRemoteB FRM220-10/100I card operation mode: 0:Switch mode 1:Converter mode
1.3.6.1.4.1.4756.20.62.20.1.37Columnf100ILfpModeRemoteBread-writecurrentRemoteB FRM220-10/100I card Link Fault Pass-through mode: 0:Disable 1:Enable
1.3.6.1.4.1.4756.20.62.20.1.38Columnf100IAlsModeRemoteBread-writecurrentRemoteB FRM220-10/100I card Auto Laser Shutdown mode: 0:Disable 1:Enable
1.3.6.1.4.1.4756.20.62.20.1.39Columnf100IFhrModeRemoteBread-writecurrentRemoteB FRM220-10/100I card accepts Fiber Hardware Reset mode: 0:Disable 1:Enable
1.3.6.1.4.1.4756.20.62.20.1.40Columnf100ISettoDefaultRemoteBread-writecurrentRemoteB FRM220-10/100I card set to default: 0:Disable 1:Enable
1.3.6.1.4.1.4756.20.62.20.1.41Columnf100IFxDDRemoteBread-onlycurrentRemoteB FRM220-10/100I card fiber Digital Diagnostic function: 0:No 1:Yes
1.3.6.1.4.1.4756.20.62.20.1.42Columnf100IDDVendorRemoteBread-onlycurrentRemoteB FRM220-10/100I card fiber D/D information: Vendor name
1.3.6.1.4.1.4756.20.62.20.1.43Columnf100IDDPartNoRemoteBread-onlycurrentRemoteB FRM220-10/100I card fiber D/D information: Vendor part number
1.3.6.1.4.1.4756.20.62.20.1.44Columnf100IDDFiberTypeRemoteBread-onlycurrentRemoteB FRM220-10/100I card fiber D/D information: Fiber Type
1.3.6.1.4.1.4756.20.62.20.1.45Columnf100IDDWaveLenRemoteBread-onlycurrentRemoteB FRM220-10/100I card fiber D/D information: Wave length
1.3.6.1.4.1.4756.20.62.20.1.46Columnf100IDDWaveLen2RemoteBread-onlycurrentRemoteB FRM220-10/100I card fiber D/D information: Wave length 2
1.3.6.1.4.1.4756.20.62.20.1.47Columnf100IDDLinkLenRemoteBread-onlycurrentRemoteB FRM220-10/100I card fiber D/D information: Link length
1.3.6.1.4.1.4756.20.62.20.1.48Columnf100IDDLenUnitRemoteBread-onlycurrentRemoteB FRM220-10/100I card fiber D/D information: Length Unit
1.3.6.1.4.1.4756.20.62.20.1.49Columnf100IDDStatusRemoteBread-onlycurrentRemoteB FRM220-10/100I card fiber D/D information: Status Support
1.3.6.1.4.1.4756.20.62.20.1.50Columnf100IDDRxSensRemoteBread-onlycurrentRemoteB FRM220-10/100I card fiber D/D information: Rx Sensitivity
1.3.6.1.4.1.4756.20.62.20.1.51Columnf100IDDTxPWRRemoteBread-onlycurrentRemoteB FRM220-10/100I card fiber D/D information: Tx power
1.3.6.1.4.1.4756.20.62.20.1.52Columnf100IDDRxPWRRemoteBread-onlycurrentRemoteB FRM220-10/100I card fiber D/D information: Rx power
1.3.6.1.4.1.4756.20.62.20.1.53Columnf100IDDTempRemoteBread-onlycurrentRemoteB FRM220-10/100I card fiber D/D information: Temperature in degree C
1.3.6.1.4.1.4756.20.62.20.1.54Columnf100IDDPWRMarginRemoteBread-onlycurrentRemoteB FRM220-10/100I card fiber D/D information: Power margin
1.3.6.1.4.1.4756.20.62.20.1.55Columnf100IDDPWRLossRemoteBread-onlycurrentRemoteB FRM220-10/100I card fiber D/D information: Power loss
1.3.6.1.4.1.4756.20.62.20.1.56Columnf100IInfoR1SN1RemoteBread-onlycurrentRemoteB FRM220-10/100I card INFORemoteBOM S/N 1 information
1.3.6.1.4.1.4756.20.62.20.1.57Columnf100IInfoR1SN2RemoteBread-onlycurrentRemoteB FRM220-10/100I card INFORemoteBOM S/N 2 information
1.3.6.1.4.1.4756.20.70NodefxoFXSLocalCards
1.3.6.1.4.1.4756.20.70.20TablefxoFXSLocalTablenot-accessiblecurrentA list of local FRM220-FXO/FXS card entries. The number of entries is fxoFXS-No-L.
1.3.6.1.4.1.4756.20.70.20.1RowfxoFXSLocalEntrynot-accessiblecurrentAn entry containing management information applicable to a particular local FRM220-FXO/FXS card.
1.3.6.1.4.1.4756.20.70.20.1.1ColumnfxoFXSChassisIndexLocalread-onlycurrentA unique value for each local card. It is the chassis location number.
1.3.6.1.4.1.4756.20.70.20.1.2ColumnfxoFXSSlotIndexLocalread-onlycurrentA unique value for each local card. It is the slot location number.
1.3.6.1.4.1.4756.20.70.20.1.3ColumnfxoFXSCardHWVerLocalread-onlycurrentLocal FRM220-FXO/FXS card hardware version x.xxx
1.3.6.1.4.1.4756.20.70.20.1.4ColumnfxoFXSCardFWVerLocalread-onlycurrentLocal FRM220-FXO/FXS card firmware version x.xxx
1.3.6.1.4.1.4756.20.70.20.1.5ColumnfxoFXSCardCPLDVerLocalread-onlycurrentLocal FRM220-FXO/FXS card CPLD version x.xxx
1.3.6.1.4.1.4756.20.70.20.1.6ColumnfxoFXSCardFPGAVerLocalread-onlycurrentLocal FRM220-FXO/FXS card FPGA version x.xxx
1.3.6.1.4.1.4756.20.70.20.1.7ColumnfxoFXSPortActiveLocalread-writecurrentLocal FRM220-FXO/FXS card active: 0:Inactive 1:Active
1.3.6.1.4.1.4756.20.70.20.1.8ColumnfxoFXSActiveStsLocalread-onlycurrentLocal FRM220-FXO/FXS FXO/FXS active state: 0:inactive 1:active
1.3.6.1.4.1.4756.20.70.20.1.9ColumnfxoFXSRingStsLocalread-onlycurrentLocal FRM220-FXO/FXS card ring state: 0:noring 1:ringing
1.3.6.1.4.1.4756.20.70.20.1.10ColumnfxoFXSFXSHookLocalread-onlycurrentLocal FRM220-FXO/FXS card FXS ON/OFF hook: 0:on-hook 1:off-hook
1.3.6.1.4.1.4756.20.70.20.1.11ColumnfxoFXSFxLinkLocalread-onlycurrentLocal FRM220-FXO/FXS fiber link state: 0:Link Down 1:Link Up
1.3.6.1.4.1.4756.20.70.20.1.12ColumnfxoFXSFxSignalLocalread-onlycurrentLocal FRM220-FXO/FXS fiber signal detected: 0:No 1:Yes
1.3.6.1.4.1.4756.20.70.20.1.13ColumnfxoFXSFxFEFLocalread-onlycurrentLocal FRM220-FXO/FXS card fiber detected Far End Fault: 0:Off 1:Detected
1.3.6.1.4.1.4756.20.70.20.1.14ColumnfxoFXSPortResetLocalread-writecurrentForce remote FRM220-FXO/FXS card to reset mode: 0:Off 1:Action
1.3.6.1.4.1.4756.20.70.20.1.15ColumnfxoFXSSetDefaultLocalread-writecurrentForce remote FRM220-FXO/FXS card to default status: 0:Off 1:Action
1.3.6.1.4.1.4756.20.70.20.1.16ColumnfxoFXSOpModeLocalread-writecurrentLocal FRM220-FXO/FXS card operation mode: 0:FXO 1:FXS (20~35Hz) 2:FXS (40~55Hz) 3:FXS Leased Mode
1.3.6.1.4.1.4756.20.70.20.1.17ColumnfxoFXSRingFreqLocalread-writecurrentLocal FRM220-FXO/FXS card ring frequency select: 0:50~55Hz 1:40~45Hz 2:30~35Hz 3:20~25Hz 4:55Hz 5:50Hz 6:45Hz 7:40Hz 8:35Hz 9:30Hz 10:25Hz 11:20Hz
1.3.6.1.4.1.4756.20.70.20.1.18ColumnfxoFXSTimingSelectLocalread-writecurrentLocal FRM220-FXO/FXS card timing select: 0:Salve 1:Master
1.3.6.1.4.1.4756.20.70.20.1.19ColumnfxoFXSLeasedLineLocalread-writecurrentLocal FRM220-FXO/FXS card leased line mode: 0:Mode2 1:Mode1
1.3.6.1.4.1.4756.20.70.20.1.20ColumnfxoFXSAlsModeLocalread-writecurrentLocal FRM220-FXO/FXS card Auto Laser Shutdown mode: 0:Disable 1:Enable
1.3.6.1.4.1.4756.20.70.20.1.21ColumnfxoFXSFxDDLocalread-onlycurrentLocal FRM220-FXO/FXS card fiber Digital Diagnostic function: 0:No 1:Yes
1.3.6.1.4.1.4756.20.70.20.1.22ColumnfxoFXSDDVendorLocalread-onlycurrentLocal FRM220-FXO/FXS card fiber D/D information: Vendor name
1.3.6.1.4.1.4756.20.70.20.1.23ColumnfxoFXSDDPartNoLocalread-onlycurrentLocal FRM220-FXO/FXS card fiber D/D information: Vendor part number
1.3.6.1.4.1.4756.20.70.20.1.24ColumnfxoFXSDDFiberTypeLocalread-onlycurrentLocal FRM220-FXO/FXS card fiber D/D information: Fiber Type
1.3.6.1.4.1.4756.20.70.20.1.25ColumnfxoFXSDDWaveLenLocalread-onlycurrentLocal FRM220-FXO/FXS card fiber D/D information: Wave length
1.3.6.1.4.1.4756.20.70.20.1.26ColumnfxoFXSDDWaveLen2Localread-onlycurrentLocal FRM220-FXO/FXS card fiber D/D information: Wave length 2
1.3.6.1.4.1.4756.20.70.20.1.27ColumnfxoFXSDDLinkLenLocalread-onlycurrentLocal FRM220-FXO/FXS card fiber D/D information: Link length
1.3.6.1.4.1.4756.20.70.20.1.28ColumnfxoFXSDDLenUnitLocalread-onlycurrentLocal FRM220-FXO/FXS card fiber D/D information: Length Unit
1.3.6.1.4.1.4756.20.70.20.1.29ColumnfxoFXSDDStatusLocalread-onlycurrentLocal FRM220-FXO/FXS card fiber D/D information: Status Support
1.3.6.1.4.1.4756.20.70.20.1.30ColumnfxoFXSDDRxSensLocalread-onlycurrentLocal FRM220-FXO/FXS card fiber D/D information: Rx Sensitivity
1.3.6.1.4.1.4756.20.70.20.1.31ColumnfxoFXSDDTxPwrLocalread-onlycurrentLocal FRM220-FXO/FXS card fiber D/D information: Tx power
1.3.6.1.4.1.4756.20.70.20.1.32ColumnfxoFXSDDRxPwrLocalread-onlycurrentLocal FRM220-FXO/FXS card fiber D/D information: Rx power
1.3.6.1.4.1.4756.20.70.20.1.33ColumnfxoFXSDDTempLocalread-onlycurrentLocal FRM220-FXO/FXS card fiber D/D information: Temperature in degree C
1.3.6.1.4.1.4756.20.70.20.1.34ColumnfxoFXSDDPwrMarginLocalread-onlycurrentLocal FRM220-FXO/FXS card fiber D/D information: Power margin
1.3.6.1.4.1.4756.20.70.20.1.35ColumnfxoFXSDDPwrLossLocalread-onlycurrentLocal FRM220-FXO/FXS card fiber D/D information: Power loss
1.3.6.1.4.1.4756.20.71NodefxoFXSRemoteCards
1.3.6.1.4.1.4756.20.71.20TablefxoFXSRemoteTablenot-accessiblecurrentA list of local FRM220-FXO/FXS card entries. The number of entries is fxoFXS-NoRemote.
1.3.6.1.4.1.4756.20.71.20.1RowfxoFXSRemoteEntrynot-accessiblecurrentAn entry containing management information applicable to a particular local FRM220-FXO/FXS card.
1.3.6.1.4.1.4756.20.71.20.1.1ColumnfxoFXSChassisIndexRemoteread-onlycurrentA unique value for each local card. It is the chassis location number.
1.3.6.1.4.1.4756.20.71.20.1.2ColumnfxoFXSSlotIndexRemoteread-onlycurrentA unique value for each remote card. It is the slot location number.
1.3.6.1.4.1.4756.20.71.20.1.3ColumnfxoFXSCardHWVerRemoteread-onlycurrentRemote FRM220-FXO/FXS card hardware version x.xxx
1.3.6.1.4.1.4756.20.71.20.1.4ColumnfxoFXSCardFWVerRemoteread-onlycurrentRemote FRM220-FXO/FXS card firmware version x.xxx
1.3.6.1.4.1.4756.20.71.20.1.5ColumnfxoFXSCardCPLDVerRemoteread-onlycurrentRemote FRM220-FXO/FXS card CPLD version x.xxx
1.3.6.1.4.1.4756.20.71.20.1.6ColumnfxoFXSCardFPGAVerRemoteread-onlycurrentRemote FRM220-FXO/FXS card FPGA version x.xxx
1.3.6.1.4.1.4756.20.71.20.1.7ColumnfxoFXSPortActiveRemoteread-onlycurrentRemote FRM220-FXO/FXS card active: 0:Inactive 1:Active
1.3.6.1.4.1.4756.20.71.20.1.8ColumnfxoFXSActiveStsRemoteread-onlycurrentRemote FRM220-FXO/FXS FXO/FXS active state: 0:inactive 1:active
1.3.6.1.4.1.4756.20.71.20.1.9ColumnfxoFXSRingStsRemoteread-onlycurrentRemote FRM220-FXO/FXS card ring state: 0:noring 1:ringing
1.3.6.1.4.1.4756.20.71.20.1.10ColumnfxoFXSFXSHookRemoteread-onlycurrentRemote FRM220-FXO/FXS card FXS ON/OFF hook: 0:on-hook 1:off-hook
1.3.6.1.4.1.4756.20.71.20.1.11ColumnfxoFXSFxLinkRemoteread-onlycurrentRemote FRM220-FXO/FXS fiber link state: 0:Link Down 1:Link Up
1.3.6.1.4.1.4756.20.71.20.1.12ColumnfxoFXSFxSignalRemoteread-onlycurrentRemote FRM220-FXO/FXS fiber signal detected: 0:No 1:Yes
1.3.6.1.4.1.4756.20.71.20.1.13ColumnfxoFXSFxFEFRemoteread-onlycurrentRemote FRM220-FXO/FXS card fiber detected Far End Fault: 0:Off 1:Detected
1.3.6.1.4.1.4756.20.71.20.1.14ColumnfxoFXSPortResetRemoteread-writecurrentForce remote FRM220-FXO/FXS card to reset mode: 0:Off 1:Action
1.3.6.1.4.1.4756.20.71.20.1.15ColumnfxoFXSSetDefaultRemoteread-writecurrentForce remote FRM220-FXO/FXS card to default status: 0:Off 1:Action
1.3.6.1.4.1.4756.20.71.20.1.16ColumnfxoFXSOpModeRemoteread-writecurrentRemote FRM220-FXO/FXS card operation mode: 0:FXO 1:FXS (20~35) 2:FXS (40~55Hz) 3:FXS Leased Mode
1.3.6.1.4.1.4756.20.71.20.1.17ColumnfxoFXSRingFreqRemoteread-writecurrentRemote FRM220-FXO/FXS card ring frequency select: 0:50~55Hz 1:40~45Hz 2:30~35Hz 3:20~25Hz 4:55Hz 5:50Hz 6:45Hz 7:40Hz 8:35Hz 9:30Hz 10:25Hz 11:20Hz
1.3.6.1.4.1.4756.20.71.20.1.18ColumnfxoFXSTimingSelectRemoteread-writecurrentRemote FRM220-FXO/FXS card timing select: 0:Salve 1:Master
1.3.6.1.4.1.4756.20.71.20.1.19ColumnfxoFXSLeasedLineRemoteread-writecurrentRemote FRM220-FXO/FXS card leased line mode: 0:Mode2 1:Mode1
1.3.6.1.4.1.4756.20.71.20.1.20ColumnfxoFXSAlsModeRemoteread-writecurrentRemote FRM220-FXO/FXS card Auto Laser Shutdown mode: 0:Disable 1:Enable
1.3.6.1.4.1.4756.20.71.20.1.21ColumnfxoFXSFxDDRemoteread-onlycurrentRemote FRM220-FXO/FXS card fiber Digital Diagnostic function: 0:No 1:Yes
1.3.6.1.4.1.4756.20.71.20.1.22ColumnfxoFXSDDVendorRemoteread-onlycurrentRemote FRM220-FXO/FXS card fiber D/D information: Vendor name
1.3.6.1.4.1.4756.20.71.20.1.23ColumnfxoFXSDDPartNoRemoteread-onlycurrentRemote FRM220-FXO/FXS card fiber D/D information: Vendor part number
1.3.6.1.4.1.4756.20.71.20.1.24ColumnfxoFXSDDFiberTypeRemoteread-onlycurrentRemote FRM220-FXO/FXS card fiber D/D information: Fiber Type
1.3.6.1.4.1.4756.20.71.20.1.25ColumnfxoFXSDDWaveLenRemoteread-onlycurrentRemote FRM220-FXO/FXS card fiber D/D information: Wave length
1.3.6.1.4.1.4756.20.71.20.1.26ColumnfxoFXSDDWaveLen2Remoteread-onlycurrentRemote FRM220-FXO/FXS card fiber D/D information: Wave length 2
1.3.6.1.4.1.4756.20.71.20.1.27ColumnfxoFXSDDLinkLenRemoteread-onlycurrentRemote FRM220-FXO/FXS card fiber D/D information: Link length
1.3.6.1.4.1.4756.20.71.20.1.28ColumnfxoFXSDDLenUnitRemoteread-onlycurrentRemote FRM220-FXO/FXS card fiber D/D information: Length Unit
1.3.6.1.4.1.4756.20.71.20.1.29ColumnfxoFXSDDStatusRemoteread-onlycurrentRemote FRM220-FXO/FXS card fiber D/D information: Status Support
1.3.6.1.4.1.4756.20.71.20.1.30ColumnfxoFXSDDRxSensRemoteread-onlycurrentRemote FRM220-FXO/FXS card fiber D/D information: Rx Sensitivity
1.3.6.1.4.1.4756.20.71.20.1.31ColumnfxoFXSDDTxPwrRemoteread-onlycurrentRemote FRM220-FXO/FXS card fiber D/D information: Tx power
1.3.6.1.4.1.4756.20.71.20.1.32ColumnfxoFXSDDRxPwrRemoteread-onlycurrentRemote FRM220-FXO/FXS card fiber D/D information: Rx power
1.3.6.1.4.1.4756.20.71.20.1.33ColumnfxoFXSDDTempRemoteread-onlycurrentRemote FRM220-FXO/FXS card fiber D/D information: Temperature in degree C
1.3.6.1.4.1.4756.20.71.20.1.34ColumnfxoFXSDDPwrMarginRemoteread-onlycurrentRemote FRM220-FXO/FXS card fiber D/D information: Power margin
1.3.6.1.4.1.4756.20.71.20.1.35ColumnfxoFXSDDPwrLossRemoteread-onlycurrentRemote FRM220-FXO/FXS card fiber D/D information: Power loss
1.3.6.1.4.1.4756.20.80NodefSERIALLocalCards
1.3.6.1.4.1.4756.20.80.20TablefSERIALLocalTablenot-accessiblecurrentA list of local FRM220-SERIAL card entries. The number of entries is fSERIAL-No-L.
1.3.6.1.4.1.4756.20.80.20.1RowfSERIALLocalEntrynot-accessiblecurrentAn entry containing management information applicable to a particular local FRM220-SERIAL card.
1.3.6.1.4.1.4756.20.80.20.1.1ColumnfSERIALChassisIndexLocalread-onlycurrentA unique value for each local card. It is the chassis location number.
1.3.6.1.4.1.4756.20.80.20.1.2ColumnfSERIALSlotIndexLocalread-onlycurrentA unique value for each local card. It is the slot location number.
1.3.6.1.4.1.4756.20.80.20.1.3ColumnfSERIALCardHWVerLocalread-onlycurrentLocal FRM220-SERIAL card hardware version x.xxx
1.3.6.1.4.1.4756.20.80.20.1.4ColumnfSERIALCardFWVerLocalread-onlycurrentLocal FRM220-SERIAL card firmware version x.xxx
1.3.6.1.4.1.4756.20.80.20.1.5ColumnfSERIALCardCPLDVerLocalread-onlycurrentLocal FRM220-SERIAL card CPLD version x.xxx
1.3.6.1.4.1.4756.20.80.20.1.6ColumnfSERIALCardFPGAVerLocalread-onlycurrentLocal FRM220-SERIAL card FPGA version x.xxx
1.3.6.1.4.1.4756.20.80.20.1.7ColumnfSERIALPortActiveLocalread-writecurrentLocal FRM220-SERIAL card active: 0:Inactive 1:Active
1.3.6.1.4.1.4756.20.80.20.1.8ColumnfSERIALDiStateLocalread-onlycurrentLocal FRM220-SERIAL data in state: 0:Space 1:Mark 2:Flash
1.3.6.1.4.1.4756.20.80.20.1.9ColumnfSERIALDoStateLocalread-onlycurrentLocal FRM220-SERIAL data out state: 0:Space 1:Mark 2:Flash
1.3.6.1.4.1.4756.20.80.20.1.10ColumnfSERIALFxLinkLocalread-onlycurrentLocal FRM220-SERIAL fiber link state: 0:Link Down 1:Link Up
1.3.6.1.4.1.4756.20.80.20.1.11ColumnfSERIALFxSignalLocalread-onlycurrentLocal FRM220-SERIAL fiber signal detected: 0:No 1:Yes
1.3.6.1.4.1.4756.20.80.20.1.12ColumnfSERIALFxFEFLocalread-onlycurrentLocal FRM220-SERIAL card fiber detected Far End Fault: 0:Off 1:Detected
1.3.6.1.4.1.4756.20.80.20.1.13ColumnfSERIALPortResetLocalread-writecurrentForce local FRM220-SERIAL card to reset mode: 0:Off 1:Action
1.3.6.1.4.1.4756.20.80.20.1.14ColumnfSERIALSetDefaultLocalread-writecurrentForce local FRM220-SERIAL card to default status: 0:Off 1:Action
1.3.6.1.4.1.4756.20.80.20.1.15ColumnfSERIALSerialModeLocalread-writecurrentLocal FRM220-SERIAL card fSERIAL- port mode: 0:RS-422 1:RS-485 2:RS-232 5 wire 3:RS-232 3 wire
1.3.6.1.4.1.4756.20.80.20.1.16ColumnfSERIALAlsModeLocalread-writecurrentLocal FRM220-SERIAL card Auto Laser Shutdown mode: 0:Disable 1:Enable
1.3.6.1.4.1.4756.20.80.20.1.17ColumnfSERIALFxDDLocalread-onlycurrentLocal FRM220-SERIAL card fiber Digital Diagnostic function: 0:No 1:Yes
1.3.6.1.4.1.4756.20.80.20.1.18ColumnfSERIALDDVendorLocalread-onlycurrentLocal FRM220-SERIAL card fiber D/D information: Vendor name
1.3.6.1.4.1.4756.20.80.20.1.19ColumnfSERIALDDPartNoLocalread-onlycurrentLocal FRM220-SERIAL card fiber D/D information: Vendor part number
1.3.6.1.4.1.4756.20.80.20.1.20ColumnfSERIALDDFiberTypeLocalread-onlycurrentLocal FRM220-SERIAL card fiber D/D information: Fiber Type
1.3.6.1.4.1.4756.20.80.20.1.21ColumnfSERIALDDWaveLenLocalread-onlycurrentLocal FRM220-SERIAL card fiber D/D information: Wave length
1.3.6.1.4.1.4756.20.80.20.1.22ColumnfSERIALDDWaveLen2Localread-onlycurrentLocal FRM220-SERIAL card fiber D/D information: Wave length 2
1.3.6.1.4.1.4756.20.80.20.1.23ColumnfSERIALDDLinkLenLocalread-onlycurrentLocal FRM220-SERIAL card fiber D/D information: Link length
1.3.6.1.4.1.4756.20.80.20.1.24ColumnfSERIALDDLenUnitLocalread-onlycurrentLocal FRM220-SERIAL card fiber D/D information: Length Unit
1.3.6.1.4.1.4756.20.80.20.1.25ColumnfSERIALDDStatusLocalread-onlycurrentLocal FRM220-SERIAL card fiber D/D information: Status Support
1.3.6.1.4.1.4756.20.80.20.1.26ColumnfSERIALDDRxSensLocalread-onlycurrentLocal FRM220-SERIAL card fiber D/D information: Rx Sensitivity
1.3.6.1.4.1.4756.20.80.20.1.27ColumnfSERIALDDTxPwrLocalread-onlycurrentLocal FRM220-SERIAL card fiber D/D information: Tx power
1.3.6.1.4.1.4756.20.80.20.1.28ColumnfSERIALDDRxPwrLocalread-onlycurrentLocal FRM220-SERIAL card fiber D/D information: Rx power
1.3.6.1.4.1.4756.20.80.20.1.29ColumnfSERIALDDTempLocalread-onlycurrentLocal FRM220-SERIAL card fiber D/D information: Temperature in degree C
1.3.6.1.4.1.4756.20.80.20.1.30ColumnfSERIALDDPwrMarginLocalread-onlycurrentLocal FRM220-SERIAL card fiber D/D information: Power margin
1.3.6.1.4.1.4756.20.80.20.1.31ColumnfSERIALDDPwrLossLocalread-onlycurrentLocal FRM220-SERIAL card fiber D/D information: Power loss
1.3.6.1.4.1.4756.20.81NodefSERIALRemoteCards
1.3.6.1.4.1.4756.20.81.20TablefSERIALRemoteTablenot-accessiblecurrentA list of local FRM220-SERIAL card entries. The number of entries is fSERIAL-NoRemote.
1.3.6.1.4.1.4756.20.81.20.1RowfSERIALRemoteEntrynot-accessiblecurrentAn entry containing management information applicable to a particular local FRM220-SERIAL card.
1.3.6.1.4.1.4756.20.81.20.1.1ColumnfSERIALChassisIndexRemoteread-onlycurrentA unique value for each local card. It is the chassis location number.
1.3.6.1.4.1.4756.20.81.20.1.2ColumnfSERIALSlotIndexRemoteread-onlycurrentA unique value for each local card. It is the slot location number.
1.3.6.1.4.1.4756.20.81.20.1.3ColumnfSERIALCardHWVerRemoteread-onlycurrentRemote FRM220-SERIAL card hardware version x.xxx
1.3.6.1.4.1.4756.20.81.20.1.4ColumnfSERIALCardFWVerRemoteread-onlycurrentRemote FRM220-SERIAL card firmware version x.xxx
1.3.6.1.4.1.4756.20.81.20.1.5ColumnfSERIALCardCPLDVerRemoteread-onlycurrentRemote FRM220-SERIAL card CPLD version x.xxx
1.3.6.1.4.1.4756.20.81.20.1.6ColumnfSERIALCardFPGAVerRemoteread-onlycurrentRemote FRM220-SERIAL card FPGA version x.xxx
1.3.6.1.4.1.4756.20.81.20.1.7ColumnfSERIALPortActiveRemoteread-onlycurrentRemote FRM220-SERIAL card active: 0:Inactive 1:Active
1.3.6.1.4.1.4756.20.81.20.1.8ColumnfSERIALDiStateRemoteread-onlycurrentRemote FRM220-SERIAL data in state: 0:Space 1:Mark 2:Flash
1.3.6.1.4.1.4756.20.81.20.1.9ColumnfSERIALDoStateRemoteread-onlycurrentRemote FRM220-SERIAL data out state: 0:Space 1:Mark 2:Flash
1.3.6.1.4.1.4756.20.81.20.1.10ColumnfSERIALFxLinkRemoteread-onlycurrentRemote FRM220-SERIAL fiber link state: 0:Link Down 1:Link Up
1.3.6.1.4.1.4756.20.81.20.1.11ColumnfSERIALFxSignalRemoteread-onlycurrentRemote FRM220-SERIAL fiber signal detected: 0:No 1:Yes
1.3.6.1.4.1.4756.20.81.20.1.12ColumnfSERIALFxFEFRemoteread-onlycurrentRemote FRM220-SERIAL card fiber detected Far End Fault: 0:Off 1:Detected
1.3.6.1.4.1.4756.20.81.20.1.13ColumnfSERIALPortResetRemoteread-writecurrentForce remote FRM220-SERIAL card to reset mode: 0:Off 1:Action
1.3.6.1.4.1.4756.20.81.20.1.14ColumnfSERIALSetDefaultRemoteread-writecurrentForce remote FRM220-SERIAL card to default status: 0:Off 1:Action
1.3.6.1.4.1.4756.20.81.20.1.15ColumnfSERIALSerialModeRemoteread-writecurrentRemote FRM220-SERIAL card fSERIAL- port mode: 0:RS-422 1:RS-485 2:RS-232 5 wire 3:RS-232 3 wire
1.3.6.1.4.1.4756.20.81.20.1.16ColumnfSERIALAlsModeRemoteread-writecurrentRemote FRM220-SERIAL card Auto Laser Shutdown mode: 0:Disable 1:Enable
1.3.6.1.4.1.4756.20.81.20.1.17ColumnfSERIALFxDDRemoteread-onlycurrentRemote FRM220-SERIAL card fiber Digital Diagnostic function: 0:No 1:Yes
1.3.6.1.4.1.4756.20.81.20.1.18ColumnfSERIALDDVendorRemoteread-onlycurrentRemote FRM220-SERIAL card fiber D/D information: Vendor name
1.3.6.1.4.1.4756.20.81.20.1.19ColumnfSERIALDDPartNoRemoteread-onlycurrentRemote FRM220-SERIAL card fiber D/D information: Vendor part number
1.3.6.1.4.1.4756.20.81.20.1.20ColumnfSERIALDDFiberTypeRemoteread-onlycurrentRemote FRM220-SERIAL card fiber D/D information: Fiber Type
1.3.6.1.4.1.4756.20.81.20.1.21ColumnfSERIALDDWaveLenRemoteread-onlycurrentRemote FRM220-SERIAL card fiber D/D information: Wave length
1.3.6.1.4.1.4756.20.81.20.1.22ColumnfSERIALDDWaveLen2Remoteread-onlycurrentRemote FRM220-SERIAL card fiber D/D information: Wave length 2
1.3.6.1.4.1.4756.20.81.20.1.23ColumnfSERIALDDLinkLenRemoteread-onlycurrentRemote FRM220-SERIAL card fiber D/D information: Link length
1.3.6.1.4.1.4756.20.81.20.1.24ColumnfSERIALDDLenUnitRemoteread-onlycurrentRemote FRM220-SERIAL card fiber D/D information: Length Unit
1.3.6.1.4.1.4756.20.81.20.1.25ColumnfSERIALDDStatusRemoteread-onlycurrentRemote FRM220-SERIAL card fiber D/D information: Status Support
1.3.6.1.4.1.4756.20.81.20.1.26ColumnfSERIALDDRxSensRemoteread-onlycurrentRemote FRM220-SERIAL card fiber D/D information: Rx Sensitivity
1.3.6.1.4.1.4756.20.81.20.1.27ColumnfSERIALDDTxPwrRemoteread-onlycurrentRemote FRM220-SERIAL card fiber D/D information: Tx power
1.3.6.1.4.1.4756.20.81.20.1.28ColumnfSERIALDDRxPwrRemoteread-onlycurrentRemote FRM220-SERIAL card fiber D/D information: Rx power
1.3.6.1.4.1.4756.20.81.20.1.29ColumnfSERIALDDTempRemoteread-onlycurrentRemote FRM220-SERIAL card fiber D/D information: Temperature in degree C
1.3.6.1.4.1.4756.20.81.20.1.30ColumnfSERIALDDPwrMarginRemoteread-onlycurrentRemote FRM220-SERIAL card fiber D/D information: Power margin
1.3.6.1.4.1.4756.20.81.20.1.31ColumnfSERIALDDPwrLossRemoteread-onlycurrentRemote FRM220-SERIAL card fiber D/D information: Power loss
1.3.6.1.4.1.4756.20.90NodefDATALocalCards
1.3.6.1.4.1.4756.20.90.20TablefDATALocalTablenot-accessiblecurrentA list of local FRM220-DATA card entries. The number of entries is fDATA-No-L.
1.3.6.1.4.1.4756.20.90.20.1RowfDATALocalEntrynot-accessiblecurrentAn entry containing management information applicable to a particular local FRM220-DATA card.
1.3.6.1.4.1.4756.20.90.20.1.1ColumnfDATAChassisIndexLocalread-onlycurrentA unique value for each local card. It is the chassis location number.
1.3.6.1.4.1.4756.20.90.20.1.2ColumnfDATASlotIndexLocalread-onlycurrentA unique value for each local card. It is the slot location number.
1.3.6.1.4.1.4756.20.90.20.1.3ColumnfDATACardHWVerLocalread-onlycurrentLocal FRM220-DATA card hardware version x.xxx
1.3.6.1.4.1.4756.20.90.20.1.4ColumnfDATACardFWVerLocalread-onlycurrentLocal FRM220-DATA card firmware version x.xxx
1.3.6.1.4.1.4756.20.90.20.1.5ColumnfDATACardCPLDVerLocalread-onlycurrentLocal FRM220-DATA card CPLD version x.xxx
1.3.6.1.4.1.4756.20.90.20.1.6ColumnfDATACardFPGAVerLocalread-onlycurrentLocal FRM220-DATA card FPGA version x.xxx
1.3.6.1.4.1.4756.20.90.20.1.7ColumnfDATAPortActiveLocalread-writecurrentLocal FRM220-DATA card active: 0:Inactive 1:Active
1.3.6.1.4.1.4756.20.90.20.1.8ColumnfDATAFxLinkLocalread-onlycurrentLocal FRM220-DATA fiber Link detected: 0:Link Down 1:Up
1.3.6.1.4.1.4756.20.90.20.1.9ColumnfDATAFxSignalLocalread-onlycurrentLocal FRM220-DATA fiber signal detected: 0:No 1:Yes
1.3.6.1.4.1.4756.20.90.20.1.10ColumnfDATAFxFEFLocalread-onlycurrentLocal FRM220-DATA card fiber detected Far End Fault: 0:Off 1:Detected
1.3.6.1.4.1.4756.20.90.20.1.11ColumnfDATAPortResetLocalread-writecurrentForce local FRM220-DATA card to reset mode: 0:Off 1:Action
1.3.6.1.4.1.4756.20.90.20.1.12ColumnfDATASetDefaultLocalread-writecurrentForce local FRM220-DATA card to default status: 0:Off 1:Action
1.3.6.1.4.1.4756.20.90.20.1.13ColumnfDATARdStateLocalread-onlycurrentLocal FRM220-DATA card RD State: 0:on 1:off 2:flash
1.3.6.1.4.1.4756.20.90.20.1.14ColumnfDATATdStateLocalread-onlycurrentLocal FRM220-DATA card TD State: 0:on 1:off 2:flash
1.3.6.1.4.1.4756.20.90.20.1.15ColumnfDATARtsStateLocalread-onlycurrentLocal FRM220-DATA card RTS State: 0:on 1:off
1.3.6.1.4.1.4756.20.90.20.1.16ColumnfDATACtsStateLocalread-onlycurrentLocal FRM220-DATA card CTS State: 0:on 1:off
1.3.6.1.4.1.4756.20.90.20.1.17ColumnfDATADcdStateLocalread-onlycurrentLocal FRM220-DATA card DCD State: 0:on 1:off
1.3.6.1.4.1.4756.20.90.20.1.18ColumnfDATAReDataRateGpLocalread-writecurrentLocal FRM220-DATA card Receive Data Rate Group Index Receive Data Rate Group Select 0 Group 1, N*64, N from 1 to 32, 64K~2048K 1 Group 2, N*64K, N from 33 to 6…
1.3.6.1.4.1.4756.20.90.20.1.19ColumnfDATAReDataRateLocalread-writecurrentLocal FRM220-DATA card Receive Data Rate Index Receive Data Rate Select Group1 Group2 Group3 Group4 Group5 Group6 Group7 0 64K 2112K 4160K 6208K 8256K 75 Reser…
1.3.6.1.4.1.4756.20.90.20.1.20ColumnfDATAReTimeSourceLocalread-writecurrentLocal FRM220-DATA card Receive Timing Source State 0:recovery from remote transmit side 1:internal 2:etc/rc input 3:recovery from remote receive side
1.3.6.1.4.1.4756.20.90.20.1.21ColumnfDATATrDataRateGpLocalread-writecurrentLocal FRM220-DATA card Transmit Data Rate Group Index Transmit Data Rate Group Select 0 Group 1, N*64, N from 1 to 32, 64K~2048K 1 Group 2, N*64K, N from 33 to…
1.3.6.1.4.1.4756.20.90.20.1.22ColumnfDATATrDataRateLocalread-writecurrentLocal FRM220-DATA card Transmit Data Rate Index Transmit Data Rate Select Group1 Group2 Group3 Group4 Group5 Group6 Group7 0 64K 2112K 4160K 6208K 8256K 75 Res…
1.3.6.1.4.1.4756.20.90.20.1.23ColumnfDATATrTimeSourceLocalread-writecurrentLocal FRM220-DATA card Transmit Timing Source State 0:Same as Reveive Timing Source 1:internal 2:etc/rc input 3:recovery from remote receive side
1.3.6.1.4.1.4756.20.90.20.1.24ColumnfDATADsrdtrLocalread-writecurrentLocal FRM220-DATA card DSR/DTR output setting 0:constantly on 1:follow local dtr/dsr input 2:follow remote dtr/dsr input
1.3.6.1.4.1.4756.20.90.20.1.25ColumnfDATACtsrtsLocalread-writecurrentLocal FRM220-DATA card CTS/RTS output setting 0:constantly on 1:follow local cts/rts input 2:follow remote cts/rts input
1.3.6.1.4.1.4756.20.90.20.1.26ColumnfDATAEtcLocalread-writecurrentLocal FRM220-DATA card ETC polarity setting 0:normal 1:invert
1.3.6.1.4.1.4756.20.90.20.1.27ColumnfDATATcLocalread-writecurrentLocal FRM220-DATA card TC polarity setting 0:normal 1:invert
1.3.6.1.4.1.4756.20.90.20.1.28ColumnfDATARcLocalread-writecurrentLocal FRM220-DATA card RC polarity setting 0:normal 1:invert
1.3.6.1.4.1.4756.20.90.20.1.29ColumnfDATAAlsModeLocalread-writecurrentLocal FRM220-DATA card Auto Laser Shutdown mode: 0:Disable 1:Enable
1.3.6.1.4.1.4756.20.90.20.1.30ColumnfDATADataPortModeLocalread-writecurrentLocal FRM220-DATA card Data Port Mode setting 0:DCE Mode 1:DTE Mode
1.3.6.1.4.1.4756.20.90.20.1.31ColumnfDATADataPotrinterfaceLocalread-writecurrentLocal FRM220-DATA card Data Port Interface setting 0:rs530-rs-449-x21 1:v35 2:rs-232
1.3.6.1.4.1.4756.20.90.20.1.32ColumnfDATALbsettingLocalread-writecurrentLocal FRM220-DATA card Loop Back Function & Select setting 0:off 1:fiber side llb 2:fiber side rlb 3:fiber side rrlb 5:data port side llb 6:data port side rlb …
1.3.6.1.4.1.4756.20.90.20.1.33ColumnfDATADcdoutsetLocalread-writecurrentLocal FRM220-DATA card DCD output setting 0:constantly on 1:follow remote dcd input
1.3.6.1.4.1.4756.20.90.20.1.34ColumnfDATADsrStateLocalread-onlycurrentLocal FRM220-DATA card DSR State 0:On 1:Off
1.3.6.1.4.1.4756.20.90.20.1.35ColumnfDATADtrStateLocalread-onlycurrentLocal FRM220-DATA card DTR State 0:On 1:Off
1.3.6.1.4.1.4756.20.90.20.1.36ColumnfDATARlbStateLocalread-onlycurrentLocal FRM220-DATA card RLB State 0:On 1:Off
1.3.6.1.4.1.4756.20.90.20.1.37ColumnfDATALlbStateLocalread-onlycurrentLocal FRM220-DATA card LLB State 0:On 1:Off
1.3.6.1.4.1.4756.20.90.20.1.38ColumnfDATATmStateLocalread-onlycurrentLocal FRM220-DATA card TM State 0:On 1:Off
1.3.6.1.4.1.4756.20.90.20.1.39ColumnfDATAFxDDLocalread-onlycurrentLocal FRM220-DATA card fiber Digital Diagnostic function: 0:No 1:Yes
1.3.6.1.4.1.4756.20.90.20.1.40ColumnfDATADDVendorLocalread-onlycurrentLocal FRM220-DATA card fiber D/D information: Vendor name
1.3.6.1.4.1.4756.20.90.20.1.41ColumnfDATADDPartNoLocalread-onlycurrentLocal FRM220-DATA card fiber D/D information: Vendor part number
1.3.6.1.4.1.4756.20.90.20.1.42ColumnfDATADDFiberTypeLocalread-onlycurrentLocal FRM220-DATA card fiber D/D information: Fiber Type
1.3.6.1.4.1.4756.20.90.20.1.43ColumnfDATADDWaveLenLocalread-onlycurrentLocal FRM220-DATA card fiber D/D information: Wave length
1.3.6.1.4.1.4756.20.90.20.1.44ColumnfDATADDWaveLen2Localread-onlycurrentLocal FRM220-DATA card fiber D/D information: Wave length 2
1.3.6.1.4.1.4756.20.90.20.1.45ColumnfDATADDLinkLenLocalread-onlycurrentLocal FRM220-DATA card fiber D/D information: Link length
1.3.6.1.4.1.4756.20.90.20.1.46ColumnfDATADDLenUnitLocalread-onlycurrentLocal FRM220-DATA card fiber D/D information: Length Unit
1.3.6.1.4.1.4756.20.90.20.1.47ColumnfDATADDStatusLocalread-onlycurrentLocal FRM220-DATA card fiber D/D information: Status Support
1.3.6.1.4.1.4756.20.90.20.1.48ColumnfDATADDRxSensLocalread-onlycurrentLocal FRM220-DATA card fiber D/D information: Rx Sensitivity
1.3.6.1.4.1.4756.20.90.20.1.49ColumnfDATADDTxPwrLocalread-onlycurrentLocal FRM220-DATA card fiber D/D information: Tx power
1.3.6.1.4.1.4756.20.90.20.1.50ColumnfDATADDRxPwrLocalread-onlycurrentLocal FRM220-DATA card fiber D/D information: Rx power
1.3.6.1.4.1.4756.20.90.20.1.51ColumnfDATADDTempLocalread-onlycurrentLocal FRM220-DATA card fiber D/D information: Temperature in degree C
1.3.6.1.4.1.4756.20.90.20.1.52ColumnfDATADDPwrMarginLocalread-onlycurrentLocal FRM220-DATA card fiber D/D information: Power margin
1.3.6.1.4.1.4756.20.90.20.1.53ColumnfDATADDPwrLossLocalread-onlycurrentLocal FRM220-DATA card fiber D/D information: Power loss
1.3.6.1.4.1.4756.20.91NodefDATARemoteCards
1.3.6.1.4.1.4756.20.91.20TablefDATARemoteTablenot-accessiblecurrentA list of local FRM220-DATA card entries. The number of entries is fDATA-NoRemote.
1.3.6.1.4.1.4756.20.91.20.1RowfDATARemoteEntrynot-accessiblecurrentAn entry containing management information applicable to a particular local FRM220-DATA card.
1.3.6.1.4.1.4756.20.91.20.1.1ColumnfDATAChassisIndexRemoteread-onlycurrentA unique value for each local card. It is the chassis location number.
1.3.6.1.4.1.4756.20.91.20.1.2ColumnfDATASlotIndexRemoteread-onlycurrentA unique value for each local card. It is the slot location number.
1.3.6.1.4.1.4756.20.91.20.1.3ColumnfDATACardHWVerRemoteread-onlycurrentRemote FRM220-DATA card hardware version x.xxx
1.3.6.1.4.1.4756.20.91.20.1.4ColumnfDATACardFWVerRemoteread-onlycurrentRemote FRM220-DATA card firmware version x.xxx
1.3.6.1.4.1.4756.20.91.20.1.5ColumnfDATACardCPLDVerRemoteread-onlycurrentRemote FRM220-DATA card CPLD version x.xxx
1.3.6.1.4.1.4756.20.91.20.1.6ColumnfDATACardFPGAVerRemoteread-onlycurrentRemote FRM220-DATA card FPGA version x.xxx
1.3.6.1.4.1.4756.20.91.20.1.7ColumnfDATAPortActiveRemoteread-onlycurrentRemote FRM220-DATA card active: 0:Inactive 1:Active
1.3.6.1.4.1.4756.20.91.20.1.8ColumnfDATAFxLinkRemoteread-onlycurrentRemote FRM220-DATA fiber Link detected: 0:Link Down 1:Up
1.3.6.1.4.1.4756.20.91.20.1.9ColumnfDATAFxSignalRemoteread-onlycurrentLocal FRM220-DATA fiber signal detected: 0:No 1:Yes
1.3.6.1.4.1.4756.20.91.20.1.10ColumnfDATAFxFEFRemoteread-onlycurrentRemote FRM220-DATA card fiber detected Far End Fault: 0:Off 1:Detected
1.3.6.1.4.1.4756.20.91.20.1.11ColumnfDATAPortResetRemoteread-writecurrentForce Remote FRM220-DATA card to reset mode: 0:Off 1:Action
1.3.6.1.4.1.4756.20.91.20.1.12ColumnfDATASetDefaultRemoteread-writecurrentForce Remote FRM220-DATA card to default status: 0:Off 1:Action
1.3.6.1.4.1.4756.20.91.20.1.13ColumnfDATARdStateRemoteread-onlycurrentRemote FRM220-DATA card RD State: 0:on 1:off 2:flash
1.3.6.1.4.1.4756.20.91.20.1.14ColumnfDATATdStateRemoteread-onlycurrentRemote FRM220-DATA card TD State: 0:on 1:off 2:flash
1.3.6.1.4.1.4756.20.91.20.1.15ColumnfDATARtsStateRemoteread-onlycurrentRemote FRM220-DATA card RTS State: 0:on 1:off
1.3.6.1.4.1.4756.20.91.20.1.16ColumnfDATACtsStateRemoteread-onlycurrentRemote FRM220-DATA card CTS State: 0:on 1:off
1.3.6.1.4.1.4756.20.91.20.1.17ColumnfDATADcdStateRemoteread-onlycurrentRemote FRM220-DATA card DCD State: 0:on 1:off
1.3.6.1.4.1.4756.20.91.20.1.18ColumnfDATAReDataRateGpRemoteread-writecurrentRemote FRM220-DATA card Receive Data Rate Group Index Receive Data Rate Group Select 0 Group 1, N*64, N from 1 to 32, 64K~2048K 1 Group 2, N*64K, N from 33 to …
1.3.6.1.4.1.4756.20.91.20.1.19ColumnfDATAReDataRateRemoteread-writecurrentRemote FRM220-DATA card Receive Data Rate Index Receive Data Rate Select Group1 Group2 Group3 Group4 Group5 Group6 Group7 0 64K 2112K 4160K 6208K 8256K 75 Rese…
1.3.6.1.4.1.4756.20.91.20.1.20ColumnfDATAReTimeSourceRemoteread-writecurrentRemote FRM220-DATA card Receive Timing Source State 0:recovery from remote transmit side 1:internal 2:etc/rc input 3:recovery from remote receive side
1.3.6.1.4.1.4756.20.91.20.1.21ColumnfDATATrDataRateGpRemoteread-writecurrentRemote FRM220-DATA card Transmit Data Rate Group Index Transmit Data Rate Group Select 0 Group 1, N*64, N from 1 to 32, 64K~2048K 1 Group 2, N*64K, N from 33 t…
1.3.6.1.4.1.4756.20.91.20.1.22ColumnfDATATrDataRateRemoteread-writecurrentRemote FRM220-DATA card Transmit Data Rate Index Transmit Data Rate Select Group1 Group2 Group3 Group4 Group5 Group6 Group7 0 64K 2112K 4160K 6208K 8256K 75 Re…
1.3.6.1.4.1.4756.20.91.20.1.23ColumnfDATATrTimeSourceRemoteread-writecurrentRemote FRM220-DATA card Transmit Timing Source State 0:Same as Reveive Timing Source 1:internal 2:etc/rc input 3:recovery from remote receive side
1.3.6.1.4.1.4756.20.91.20.1.24ColumnfDATADsrdtrRemoteread-writecurrentRemote FRM220-DATA card DSR/DTR output setting 0:constantly on 1:follow local dtr/dsr input 2:follow remote dtr/dsr input
1.3.6.1.4.1.4756.20.91.20.1.25ColumnfDATACtsrtsRemoteread-writecurrentRemote FRM220-DATA card CTS/RTS output setting 0:constantly on 1:follow local cts/rts input 2:follow remote cts/rts input
1.3.6.1.4.1.4756.20.91.20.1.26ColumnfDATAEtcRemoteread-writecurrentRemote FRM220-DATA card ETC polarity setting 0:normal 1:invert
1.3.6.1.4.1.4756.20.91.20.1.27ColumnfDATATcRemoteread-writecurrentRemote FRM220-DATA card TC polarity setting 0:normal 1:invert
1.3.6.1.4.1.4756.20.91.20.1.28ColumnfDATARcRemoteread-writecurrentRemote FRM220-DATA card RC polarity setting 0:normal 1:invert
1.3.6.1.4.1.4756.20.91.20.1.29ColumnfDATAAlsModeRemoteread-writecurrentRemote FRM220-DATA card Auto Laser Shutdown mode: 0:Disable 1:Enable
1.3.6.1.4.1.4756.20.91.20.1.30ColumnfDATADataPortModeRemoteread-writecurrentRemote FRM220-DATA card Data Port Mode setting 0:DCE Mode 1:DTE Mode
1.3.6.1.4.1.4756.20.91.20.1.31ColumnfDATADataPotrinterfaceRemoteread-writecurrentRemote FRM220-DATA card Data Port Interface setting 0:rs530Remotes-449-x21 1:v35 2:rs-232
1.3.6.1.4.1.4756.20.91.20.1.32ColumnfDATALbsettingRemoteread-writecurrentRemote FRM220-DATA card Loop Back Function & Select setting 0:off 5:data port side llb 6:data port side rlb 7:data port side rrlb
1.3.6.1.4.1.4756.20.91.20.1.33ColumnfDATADcdoutsetRemoteread-writecurrentRemote FRM220-DATA card DCD output setting 0:constantly on 1:follow remote dcd input
1.3.6.1.4.1.4756.20.91.20.1.34ColumnfDATADsrStateRemoteread-onlycurrentRemote FRM220-DATA card DSR State 0:On 1:Off
1.3.6.1.4.1.4756.20.91.20.1.35ColumnfDATADtrStateRemoteread-onlycurrentRemote FRM220-DATA card DTR State 0:On 1:Off
1.3.6.1.4.1.4756.20.91.20.1.36ColumnfDATARlbStateRemoteread-onlycurrentRemote FRM220-DATA card RLB State 0:On 1:Off
1.3.6.1.4.1.4756.20.91.20.1.37ColumnfDATALlbStateRemoteread-onlycurrentRemote FRM220-DATA card LLB State 0:On 1:Off
1.3.6.1.4.1.4756.20.91.20.1.38ColumnfDATATmStateRemoteread-onlycurrentRemote FRM220-DATA card TM State 0:On 1:Off
1.3.6.1.4.1.4756.20.91.20.1.39ColumnfDATAFxDDRemoteread-onlycurrentRemote FRM220-DATA card fiber Digital Diagnostic function: 0:No 1:Yes
1.3.6.1.4.1.4756.20.91.20.1.40ColumnfDATADDVendorRemoteread-onlycurrentRemote FRM220-DATA card fiber D/D information: Vendor name
1.3.6.1.4.1.4756.20.91.20.1.41ColumnfDATADDPartNoRemoteread-onlycurrentRemote FRM220-DATA card fiber D/D information: Vendor part number
1.3.6.1.4.1.4756.20.91.20.1.42ColumnfDATADDFiberTypeRemoteread-onlycurrentRemote FRM220-DATA card fiber D/D information: Fiber Type
1.3.6.1.4.1.4756.20.91.20.1.43ColumnfDATADDWaveLenRemoteread-onlycurrentRemote FRM220-DATA card fiber D/D information: Wave length
1.3.6.1.4.1.4756.20.91.20.1.44ColumnfDATADDWaveLen2Remoteread-onlycurrentRemote FRM220-DATA card fiber D/D information: Wave length 2
1.3.6.1.4.1.4756.20.91.20.1.45ColumnfDATADDLinkLenRemoteread-onlycurrentRemote FRM220-DATA card fiber D/D information: Link length
1.3.6.1.4.1.4756.20.91.20.1.46ColumnfDATADDLenUnitRemoteread-onlycurrentRemote FRM220-DATA card fiber D/D information: Length Unit
1.3.6.1.4.1.4756.20.91.20.1.47ColumnfDATADDStatusRemoteread-onlycurrentRemote FRM220-DATA card fiber D/D information: Status Support
1.3.6.1.4.1.4756.20.91.20.1.48ColumnfDATADDRxSensRemoteread-onlycurrentRemote FRM220-DATA card fiber D/D information: Rx Sensitivity
1.3.6.1.4.1.4756.20.91.20.1.49ColumnfDATADDTxPwrRemoteread-onlycurrentRemote FRM220-DATA card fiber D/D information: Tx power
1.3.6.1.4.1.4756.20.91.20.1.50ColumnfDATADDRxPwrRemoteread-onlycurrentRemote FRM220-DATA card fiber D/D information: Rx power
1.3.6.1.4.1.4756.20.91.20.1.51ColumnfDATADDTempRemoteread-onlycurrentRemote FRM220-DATA card fiber D/D information: Temperature in degree C
1.3.6.1.4.1.4756.20.91.20.1.52ColumnfDATADDPwrMarginRemoteread-onlycurrentRemote FRM220-DATA card fiber D/D information: Power margin
1.3.6.1.4.1.4756.20.91.20.1.53ColumnfDATADDPwrLossRemoteread-onlycurrentRemote FRM220-DATA card fiber D/D information: Power loss
1.3.6.1.4.1.4756.20.100NodefE1T1LocalCards
1.3.6.1.4.1.4756.20.100.20TablefE1T1LocalTablenot-accessiblecurrentA list of local FRM220-DATA card entries. The number of entries is fE1T1-No-L.
1.3.6.1.4.1.4756.20.100.20.1RowfE1T1LocalEntrynot-accessiblecurrentAn entry containing management information applicable to a particular local FRM220-E1T1 card.
1.3.6.1.4.1.4756.20.100.20.1.1ColumnfE1T1ChassisIndexLocalread-onlycurrentA unique value for each local card. It is the chassis location number.
1.3.6.1.4.1.4756.20.100.20.1.2ColumnfE1T1SlotIndexLocalread-onlycurrentA unique value for each local card. It is the slot location number.
1.3.6.1.4.1.4756.20.100.20.1.3ColumnfE1T1CardHWVerLocalread-onlycurrentLocal FRM220-E1/T1 card hardware version x.xxx
1.3.6.1.4.1.4756.20.100.20.1.4ColumnfE1T1CardFWVerLocalread-onlycurrentLocal FRM220-E1/T1 card firmware version x.xxx
1.3.6.1.4.1.4756.20.100.20.1.5ColumnfE1T1CardCPLDVerLocalread-onlycurrentLocal FRM220-E1/T1 card CPLD version x.xxx
1.3.6.1.4.1.4756.20.100.20.1.6ColumnfE1T1CardFPGAVerLocalread-onlycurrentLocal FRM220-E1/T1 card FPGA version x.xxx
1.3.6.1.4.1.4756.20.100.20.1.7ColumnfE1T1PortActiveLocalread-writecurrentLocal FRM220-E1/T1 card active: 0:Inactive 1:Active
1.3.6.1.4.1.4756.20.100.20.1.8ColumnfE1T1SignalLocalread-onlycurrentLocal FRM220-E1/T1 card active: 0:signal-loss 1:normal
1.3.6.1.4.1.4756.20.100.20.1.9ColumnfE1T1SyncLocalread-onlycurrentLocal FRM220-E1/T1 card active: 0:sync-loss 1:sync
1.3.6.1.4.1.4756.20.100.20.1.10ColumnfE1T1ReAISLocalread-onlycurrentLocal FRM220-E1/T1 card active: 0:no 1:yes
1.3.6.1.4.1.4756.20.100.20.1.11ColumnfE1T1ConTypeLocalread-onlycurrentLocal FRM220-E1/T1 card active: 0:rj-48c 1:bnc
1.3.6.1.4.1.4756.20.100.20.1.12ColumnfE1T1FxLinkLocalread-onlycurrentLocal FRM220-E1/T1 fiber Link detected: 0:Link Down 1:Up
1.3.6.1.4.1.4756.20.100.20.1.13ColumnfE1T1FxSignalLocalread-onlycurrentLocal FRM220-E1/T1 fiber signal detected: 0:No 1:Yes
1.3.6.1.4.1.4756.20.100.20.1.14ColumnfE1T1FxFEFLocalread-onlycurrentLocal FRM220-E1/T1 card fiber detected Far End Fault: 0:Off 1:Detected
1.3.6.1.4.1.4756.20.100.20.1.15ColumnfE1T1PortResetLocalread-writecurrentForce local FRM220-E1/T1 card to reset mode: 0:Off 1:Action
1.3.6.1.4.1.4756.20.100.20.1.16ColumnfE1T1SetDefaultLocalread-writecurrentForce local FRM220-E1/T1 card to default status: 0:Off 1:Action
1.3.6.1.4.1.4756.20.100.20.1.17ColumnfE1T1E1T1selLocalread-writecurrentLocal FRM220-E1/T1 card E1/T1 Select: 0:e1 1:t1
1.3.6.1.4.1.4756.20.100.20.1.18ColumnfE1T1LineCodeLocalread-writecurrentLocal FRM220-E1/T1 card E1/T1 Line Code setting: 0:hdb3-b8zs 1:ami
1.3.6.1.4.1.4756.20.100.20.1.19ColumnfE1T1FullFractionalLocalread-writecurrentLocal FRM220-E1/T1 card E1/T1 Full/Fractional: 0:full-e1t1 1:fraction-e1t1
1.3.6.1.4.1.4756.20.100.20.1.20ColumnfE1T1FramerLocalread-writecurrentLocal FRM220-E1/T1 card E1/T1 Framer setting: 0:ccs-d4 1:cas-esf
1.3.6.1.4.1.4756.20.100.20.1.21ColumnfE1T1CrcLocalread-writecurrentLocal FRM220-E1/T1 card CRC setting: 0:disable 1:enable
1.3.6.1.4.1.4756.20.100.20.1.22ColumnfE1T1RelossTraisLocalread-writecurrentLocal FRM220-E1/T1 card Receive loss transmit AIS: 0:disable 1:enable
1.3.6.1.4.1.4756.20.100.20.1.23ColumnfE1T1UnusedTimeslotCodeLocalread-writecurrentLocal FRM220-E1/T1 card Unused timeslot code setting: 0:0x7e 1:0xff
1.3.6.1.4.1.4756.20.100.20.1.24ColumnfE1T1TrtimesourceLocalread-writecurrentLocal FRM220-E1/T1 card Timing Source: 0:recovery from remote transmit side 1:recovery-from-e1t1 Receive 2:internal-oscillator 3:reserve
1.3.6.1.4.1.4756.20.100.20.1.25ColumnfE1T1AlsLocalread-writecurrentLocal FRM220-E1/T1 card Auto Laser Shutdown: 0:disable 1:enable
1.3.6.1.4.1.4756.20.100.20.1.26ColumnfE1T1RateLocalread-writecurrentLocal FRM220-E1/T1 card Active Timeslot Numbers: E1 : CCS Mode CAS Mode T1: 1 64K 64K 64K 2 128K 128K 128K 3 192K 192K 192K 4 256K 256K 256K 5 320K 320K 320K 6…
1.3.6.1.4.1.4756.20.100.20.1.27ColumnfE1T1TimeslotLocalread-writecurrentLocal FRM220-E1/T1 card Start Timeslot:
1.3.6.1.4.1.4756.20.100.20.1.28ColumnfE1T1LbsettingLocalread-writecurrentLocal FRM220-E1/T1 card Loop Back setting: 0:off 1:fiber-side-llb 2:fiber-side-rlb 3:fiber-side-rrlb 5:e1t1-port-side-llb 6:e1t1-port-side-rlb 7:e1t1-port-side…
1.3.6.1.4.1.4756.20.100.20.1.29ColumnfE1T1RdstateLocalread-onlycurrentLocal FRM220-E1/T1 card RD state: 0:on 1:off 2:flash
1.3.6.1.4.1.4756.20.100.20.1.30ColumnfE1T1TdstateLocalread-onlycurrentLocal FRM220-E1/T1 card TD state: 0:on 1:off 2:flash
1.3.6.1.4.1.4756.20.100.20.1.31ColumnfE1T1TeststateLocalread-onlycurrentLocal FRM220-E1/T1 card Test mode: 0:normal 1:at-test-mode
1.3.6.1.4.1.4756.20.100.20.1.32ColumnfE1T1FxDDLocalread-onlycurrentLocal FRM220-E1/T1 card fiber Digital Diagnostic function: 0:No 1:Yes
1.3.6.1.4.1.4756.20.100.20.1.33ColumnfE1T1DDVendorLocalread-onlycurrentLocal FRM220-E1/T1 card fiber D/D information: Vendor name
1.3.6.1.4.1.4756.20.100.20.1.34ColumnfE1T1DDPartNoLocalread-onlycurrentLocal FRM220-E1/T1 card fiber D/D information: Vendor part number
1.3.6.1.4.1.4756.20.100.20.1.35ColumnfE1T1DDFiberTypeLocalread-onlycurrentLocal FRM220-E1/T1 card fiber D/D information: Fiber Type
1.3.6.1.4.1.4756.20.100.20.1.36ColumnfE1T1DDWaveLenLocalread-onlycurrentLocal FRM220-E1/T1 card fiber D/D information: Wave length
1.3.6.1.4.1.4756.20.100.20.1.37ColumnfE1T1DDWaveLen2Localread-onlycurrentLocal FRM220-E1/T1 card fiber D/D information: Wave length 2
1.3.6.1.4.1.4756.20.100.20.1.38ColumnfE1T1DDLinkLenLocalread-onlycurrentLocal FRM220-E1/T1 card fiber D/D information: Link length
1.3.6.1.4.1.4756.20.100.20.1.39ColumnfE1T1DDLenUnitLocalread-onlycurrentLocal FRM220-E1/T1 card fiber D/D information: Length Unit
1.3.6.1.4.1.4756.20.100.20.1.40ColumnfE1T1DDStatusLocalread-onlycurrentLocal FRM220-E1/T1 card fiber D/D information: Status Support
1.3.6.1.4.1.4756.20.100.20.1.41ColumnfE1T1DDRxSensLocalread-onlycurrentLocal FRM220-E1/T1 card fiber D/D information: Rx Sensitivity
1.3.6.1.4.1.4756.20.100.20.1.42ColumnfE1T1DDTxPwrLocalread-onlycurrentLocal FRM220-E1/T1 card fiber D/D information: Tx power
1.3.6.1.4.1.4756.20.100.20.1.43ColumnfE1T1DDRxPwrLocalread-onlycurrentLocal FRM220-E1/T1 card fiber D/D information: Rx power
1.3.6.1.4.1.4756.20.100.20.1.44ColumnfE1T1DDTempLocalread-onlycurrentLocal FRM220-E1/T1 card fiber D/D information: Temperature in degree C
1.3.6.1.4.1.4756.20.100.20.1.45ColumnfE1T1DDPwrMarginLocalread-onlycurrentLocal FRM220-E1/T1 card fiber D/D information: Power margin
1.3.6.1.4.1.4756.20.100.20.1.46ColumnfE1T1DDPwrLossLocalread-onlycurrentLocal FRM220-E1/T1 card fiber D/D information: Power loss
1.3.6.1.4.1.4756.20.100.20.1.47ColumnfE1T1FxLinkAlarmLocalread-writecurrentLocal FRM220-E1/T1 card fiber link alarm 0:Disable 1:Enable
1.3.6.1.4.1.4756.20.100.20.1.48ColumnfE1T1LinkAlarmLocalread-writecurrentLocal FRM220-E1/T1 card E1T1 link alarm 0:Disable 1:Enable
1.3.6.1.4.1.4756.20.101NodefE1T1remoteCards
1.3.6.1.4.1.4756.20.101.20TablefE1T1RemoteTablenot-accessiblecurrentA list of local FRM220-E1/T1 card entries. The number of entries is fE1T1-NoRemote.
1.3.6.1.4.1.4756.20.101.20.1RowfE1T1RemoteEntrynot-accessiblecurrentAn entry containing management information applicable to a particular local FRM220-E1T1 card.
1.3.6.1.4.1.4756.20.101.20.1.1ColumnfE1T1ChassisIndexRemoteread-onlycurrentA unique value for each Remote card. It is the chassis location number.
1.3.6.1.4.1.4756.20.101.20.1.2ColumnfE1T1SlotIndexRemoteread-onlycurrentA unique value for each Remote card. It is the slot location number.
1.3.6.1.4.1.4756.20.101.20.1.3ColumnfE1T1CardHWVerRemoteread-onlycurrentRemote FRM220-E1/T1 card hardware version x.xxx
1.3.6.1.4.1.4756.20.101.20.1.4ColumnfE1T1CardFWVerRemoteread-onlycurrentRemote FRM220-E1/T1 card firmware version x.xxx
1.3.6.1.4.1.4756.20.101.20.1.5ColumnfE1T1CardCPLDVerRemoteread-onlycurrentRemote FRM220-E1/T1 card CPLD version x.xxx
1.3.6.1.4.1.4756.20.101.20.1.6ColumnfE1T1CardFPGAVerRemoteread-onlycurrentRemote FRM220-E1/T1 card FPGA version x.xxx
1.3.6.1.4.1.4756.20.101.20.1.7ColumnfE1T1PortActiveRemoteread-onlycurrentRemote FRM220-E1/T1 card active: 0:Inactive 1:Active
1.3.6.1.4.1.4756.20.101.20.1.8ColumnfE1T1SignalRemoteread-onlycurrentRemote FRM220-E1/T1 card active: 0:signal-loss 1:normal
1.3.6.1.4.1.4756.20.101.20.1.9ColumnfE1T1SyncRemoteread-onlycurrentRemote FRM220-E1/T1 card active: 0:sync-loss 1:sync
1.3.6.1.4.1.4756.20.101.20.1.10ColumnfE1T1ReAISRemoteread-onlycurrentRemote FRM220-E1/T1 card active: 0:no 1:yes
1.3.6.1.4.1.4756.20.101.20.1.11ColumnfE1T1ConTypeRemoteread-onlycurrentRemote FRM220-E1/T1 card active: 0:rj-48c 1:bnc
1.3.6.1.4.1.4756.20.101.20.1.12ColumnfE1T1FxLinkRemoteread-onlycurrentRemote FRM220-E1/T1 fiber Link detected: 0:Link Down 1:Up
1.3.6.1.4.1.4756.20.101.20.1.13ColumnfE1T1FxSignalRemoteread-onlycurrentRemote FRM220-E1/T1 fiber signal detected: 0:No 1:Yes
1.3.6.1.4.1.4756.20.101.20.1.14ColumnfE1T1FxFEFRemoteread-onlycurrentRemote FRM220-E1/T1 card fiber detected Far End Fault: 0:Off 1:Detected
1.3.6.1.4.1.4756.20.101.20.1.15ColumnfE1T1PortResetRemoteread-writecurrentForce Remote FRM220-E1/T1 card to reset mode: 0:Off 1:Action
1.3.6.1.4.1.4756.20.101.20.1.16ColumnfE1T1SetDefaultRemoteread-writecurrentForce Remote FRM220-E1/T1 card to default status: 0:Off 1:Action
1.3.6.1.4.1.4756.20.101.20.1.17ColumnfE1T1E1T1selRemoteread-writecurrentRemote FRM220-E1/T1 card E1/T1 Select: 0:e1 1:t1
1.3.6.1.4.1.4756.20.101.20.1.18ColumnfE1T1LineCodeRemoteread-writecurrentRemote FRM220-E1/T1 card E1/T1 Line Code setting: 0:hdb3-b8zs 1:ami
1.3.6.1.4.1.4756.20.101.20.1.19ColumnfE1T1FullFractionalRemoteread-writecurrentRemote FRM220-E1/T1 card E1/T1 Full/Fractional: 0:full-e1t1 1:fraction-e1t1
1.3.6.1.4.1.4756.20.101.20.1.20ColumnfE1T1FramerRemoteread-writecurrentRemote FRM220-E1/T1 card E1/T1 Framer setting: 0:ccs-d4 1:cas-esf
1.3.6.1.4.1.4756.20.101.20.1.21ColumnfE1T1CrcRemoteread-writecurrentRemote FRM220-E1/T1 card CRC setting: 0:disable 1:enable
1.3.6.1.4.1.4756.20.101.20.1.22ColumnfE1T1RelossTraisRemoteread-writecurrentRemote FRM220-E1/T1 card Receive loss transmit AIS: 0:disable 1:enable
1.3.6.1.4.1.4756.20.101.20.1.23ColumnfE1T1UnusedTimeslotCodeRemoteread-writecurrentRemote FRM220-E1/T1 card Unused timeslot code setting: 0:0x7e 1:0xff
1.3.6.1.4.1.4756.20.101.20.1.24ColumnfE1T1TrtimesourceRemoteread-writecurrentRemote FRM220-E1/T1 card Timing Source: 0:recovery from remote transmit side 1:recovery-from-e1t1 Receive 2:internal-oscillator 3:reserve
1.3.6.1.4.1.4756.20.101.20.1.25ColumnfE1T1AlsRemoteread-writecurrentRemote FRM220-E1/T1 card Auto Laser Shutdown: 0:disable 1:enable
1.3.6.1.4.1.4756.20.101.20.1.26ColumnfE1T1RateRemoteread-writecurrentRemote FRM220-E1/T1 card Active Timeslot Numbers: E1 : CCS Mode CAS Mode T1: 1 64K 64K 64K 2 128K 128K 128K 3 192K 192K 192K 4 256K 256K 256K 5 320K 320K 320K …
1.3.6.1.4.1.4756.20.101.20.1.27ColumnfE1T1TimeslotRemoteread-writecurrentRemote FRM220-E1/T1 card Start Timeslot:
1.3.6.1.4.1.4756.20.101.20.1.28ColumnfE1T1LbsettingRemoteread-writecurrentRemote FRM220-E1/T1 card Loop Back setting: 0:off 5:e1t1-port-side-llb 6:e1t1-port-side-rlb 7:e1t1-port-side-rrlb
1.3.6.1.4.1.4756.20.101.20.1.29ColumnfE1T1RdstateRemoteread-onlycurrentRemote FRM220-E1/T1 card RD state: 0:on 1:off 2:flash
1.3.6.1.4.1.4756.20.101.20.1.30ColumnfE1T1TdstateRemoteread-onlycurrentRemote FRM220-E1/T1 card TD state: 0:on 1:off 2:flash
1.3.6.1.4.1.4756.20.101.20.1.31ColumnfE1T1TeststateRemoteread-onlycurrentRemote FRM220-E1/T1 card Test mode: 0:normal 1:at-test-mode
1.3.6.1.4.1.4756.20.101.20.1.32ColumnfE1T1FxDDRemoteread-onlycurrentRemote FRM220-E1/T1 card fiber Digital Diagnostic function: 0:No 1:Yes
1.3.6.1.4.1.4756.20.101.20.1.33ColumnfE1T1DDVendorRemoteread-onlycurrentRemote FRM220-E1/T1 card fiber D/D information: Vendor name
1.3.6.1.4.1.4756.20.101.20.1.34ColumnfE1T1DDPartNoRemoteread-onlycurrentRemote FRM220-E1/T1 card fiber D/D information: Vendor part number
1.3.6.1.4.1.4756.20.101.20.1.35ColumnfE1T1DDFiberTypeRemoteread-onlycurrentRemote FRM220-E1/T1 card fiber D/D information: Fiber Type
1.3.6.1.4.1.4756.20.101.20.1.36ColumnfE1T1DDWaveLenRemoteread-onlycurrentRemote FRM220-E1/T1 card fiber D/D information: Wave length
1.3.6.1.4.1.4756.20.101.20.1.37ColumnfE1T1DDWaveLen2Remoteread-onlycurrentRemote FRM220-E1/T1 card fiber D/D information: Wave length 2
1.3.6.1.4.1.4756.20.101.20.1.38ColumnfE1T1DDLinkLenRemoteread-onlycurrentRemote FRM220-E1/T1 card fiber D/D information: Link length
1.3.6.1.4.1.4756.20.101.20.1.39ColumnfE1T1DDLenUnitRemoteread-onlycurrentRemote FRM220-E1/T1 card fiber D/D information: Length Unit
1.3.6.1.4.1.4756.20.101.20.1.40ColumnfE1T1DDStatusRemoteread-onlycurrentRemote FRM220-E1/T1 card fiber D/D information: Status Support
1.3.6.1.4.1.4756.20.101.20.1.41ColumnfE1T1DDRxSensRemoteread-onlycurrentRemote FRM220-E1/T1 card fiber D/D information: Rx Sensitivity
1.3.6.1.4.1.4756.20.101.20.1.42ColumnfE1T1DDTxPwrRemoteread-onlycurrentRemote FRM220-E1/T1 card fiber D/D information: Tx power
1.3.6.1.4.1.4756.20.101.20.1.43ColumnfE1T1DDRxPwrRemoteread-onlycurrentRemote FRM220-E1/T1 card fiber D/D information: Rx power
1.3.6.1.4.1.4756.20.101.20.1.44ColumnfE1T1DDTempRemoteread-onlycurrentRemote FRM220-E1/T1 card fiber D/D information: Temperature in degree C
1.3.6.1.4.1.4756.20.101.20.1.45ColumnfE1T1DDPwrMarginRemoteread-onlycurrentRemote FRM220-E1/T1 card fiber D/D information: Power margin
1.3.6.1.4.1.4756.20.101.20.1.46ColumnfE1T1DDPwrLossRemoteread-onlycurrentRemote FRM220-E1/T1 card fiber D/D information: Power loss
1.3.6.1.4.1.4756.20.101.20.1.47ColumnfE1T1FxLinkAlarmRemoteread-writecurrentRemote FRM220-E1/T1 card fiber link alarm 0:Disable 1:Enable
1.3.6.1.4.1.4756.20.101.20.1.48ColumnfE1T1LinkAlarmRemoteread-writecurrentRemote FRM220-E1/T1 card E1T1 link alarm 0:Disable 1:Enable
1.3.6.1.4.1.4756.20.110Nodef5E1LocalCards
1.3.6.1.4.1.4756.20.110.20Tablef5E1LocalTablenot-accessiblecurrentA list of local FRM220-5E1-ET100 series card entries. The number of entries is f5E1-No-L.
1.3.6.1.4.1.4756.20.110.20.1Rowf5E1LocalEntrynot-accessiblecurrentAn entry containing management information applicable to a particular local FRM220-5E1 series card.
1.3.6.1.4.1.4756.20.110.20.1.1Columnfa5e1et100ChassisIndexLocalread-onlycurrentA unique value for each card. It starts from 0 to 9 contiguously.
1.3.6.1.4.1.4756.20.110.20.1.2Columnfa5e1et100SlotIndexLocalread-onlycurrentA unique value for each card. It starts from 1 to 20 contiguously.
1.3.6.1.4.1.4756.20.110.20.1.3Columnfa5e1et100CardHWVerLocalread-onlycurrent5E1-ET100(T/S) Series card hardware version x.xxx
1.3.6.1.4.1.4756.20.110.20.1.4Columnfa5e1et100CardFWVerLocalread-onlycurrent5E1-ET100(T/S) Series card firmware version x.xxx
1.3.6.1.4.1.4756.20.110.20.1.5Columnfa5e1et100CardCPLDVerLocalread-onlycurrent5E1-ET100(T/S) Series card CPLD version x.xxx
1.3.6.1.4.1.4756.20.110.20.1.6Columnfa5e1et100CardFPGAVerLocalread-onlycurrent5E1-ET100(T/S) Series card FPGA version x.xxx
1.3.6.1.4.1.4756.20.110.20.1.7Columnfa5e1et100ModelLocalread-onlycurrentCard Type: 0:5E1-ET100T 1:5E1-ET100S
1.3.6.1.4.1.4756.20.110.20.1.8Columnfa5e1et100SystemStatusLocalread-onlycurrent5E1-ET100(T/S) Series card system status: 0:Normal 1:Alarm
1.3.6.1.4.1.4756.20.110.20.1.9Columnfa5e1et100DeviceActiveLocalread-writecurrent5E1-ET100(T/S) Series card active: 0:Disable 1:Enable
1.3.6.1.4.1.4756.20.110.20.1.10Columnfa5e1et100SetToDefaultLocalread-writecurrent5E1-ET100(T/S) Series card port set to default: 0:Off 1:Trigger
1.3.6.1.4.1.4756.20.110.20.1.11Columnfa5e1et100E1Ch1SingalLocalread-onlycurrent5E1-ET100(T/S) Series card E1 channel 1 signal status: 0:Singal Loss 1:Normal
1.3.6.1.4.1.4756.20.110.20.1.12Columnfa5e1et100E1Ch2SingalLocalread-onlycurrent5E1-ET100(T/S) Series card E1 channel 2 signal status: 0:Singal Loss 1:Normal
1.3.6.1.4.1.4756.20.110.20.1.13Columnfa5e1et100E1Ch3SingalLocalread-onlycurrent5E1-ET100(T/S) Series card E1 channel 3 signal status: 0:Singal Loss 1:Normal
1.3.6.1.4.1.4756.20.110.20.1.14Columnfa5e1et100E1Ch4SingalLocalread-onlycurrent5E1-ET100(T/S) Series card E1 channel 4 signal status: 0:Singal Loss 1:Normal
1.3.6.1.4.1.4756.20.110.20.1.15Columnfa5e1et100E1Ch5SingalLocalread-onlycurrent5E1-ET100(T/S) Series card E1 channel 5 signal status: 0:Singal Loss 1:Normal
1.3.6.1.4.1.4756.20.110.20.1.16Columnfa5e1et100E1Ch1SyncLocalread-onlycurrent5E1-ET100(T/S) Series card E1 channel 1 sync status: 0:Sync Loss 1:Sync
1.3.6.1.4.1.4756.20.110.20.1.17Columnfa5e1et100E1Ch2SyncLocalread-onlycurrent5E1-ET100(T/S) Series card E1 channel 2 sync status: 0:Sync Loss 1:Sync
1.3.6.1.4.1.4756.20.110.20.1.18Columnfa5e1et100E1Ch3SyncLocalread-onlycurrent5E1-ET100(T/S) Series card E1 channel 3 sync status: 0:Sync Loss 1:Sync
1.3.6.1.4.1.4756.20.110.20.1.19Columnfa5e1et100E1Ch4SyncLocalread-onlycurrent5E1-ET100(T/S) Series card E1 channel 4 sync status: 0:Sync Loss 1:Sync
1.3.6.1.4.1.4756.20.110.20.1.20Columnfa5e1et100E1Ch5SyncLocalread-onlycurrent5E1-ET100(T/S) Series card E1 channel 5 sync status: 0:Sync Loss 1:Sync
1.3.6.1.4.1.4756.20.110.20.1.21Columnfa5e1et100E1Ch1RecvAISLocalread-onlycurrent5E1-ET100(T/S) Series card E1 channel 1 receive AIS status: 0:No 1:Yes
1.3.6.1.4.1.4756.20.110.20.1.22Columnfa5e1et100E1Ch2RecvAISLocalread-onlycurrent5E1-ET100(T/S) Series card E1 channel 2 receive AIS status: 0:No 1:Yes
1.3.6.1.4.1.4756.20.110.20.1.23Columnfa5e1et100E1Ch3RecvAISLocalread-onlycurrent5E1-ET100(T/S) Series card E1 channel 3 receive AIS status: 0:No 1:Yes
1.3.6.1.4.1.4756.20.110.20.1.24Columnfa5e1et100E1Ch4RecvAISLocalread-onlycurrent5E1-ET100(T/S) Series card E1 channel 4 receive AIS status: 0:No 1:Yes
1.3.6.1.4.1.4756.20.110.20.1.25Columnfa5e1et100E1Ch5RecvAISLocalread-onlycurrent5E1-ET100(T/S) Series card E1 channel 5 receive AIS status: 0:No 1:Yes
1.3.6.1.4.1.4756.20.110.20.1.26Columnfa5e1et100E1Ch1ConnTypeLocalread-onlycurrent5E1-ET100(T/S) Series card E1 channel 1 connector type: 0:RJ-48C 1:BNC
1.3.6.1.4.1.4756.20.110.20.1.27Columnfa5e1et100E1Ch2ConnTypeLocalread-onlycurrent5E1-ET100(T/S) Series card E1 channel 2 connector type: 0:RJ-48C 1:BNC
1.3.6.1.4.1.4756.20.110.20.1.28Columnfa5e1et100E1Ch3ConnTypeLocalread-onlycurrent5E1-ET100(T/S) Series card E1 channel 3 connector type: 0:RJ-48C 1:BNC
1.3.6.1.4.1.4756.20.110.20.1.29Columnfa5e1et100E1Ch4ConnTypeLocalread-onlycurrent5E1-ET100(T/S) Series card E1 channel 4 connector type: 0:RJ-48C 1:BNC
1.3.6.1.4.1.4756.20.110.20.1.30Columnfa5e1et100E1Ch5ConnTypeLocalread-onlycurrent5E1-ET100(T/S) Series card E1 channel 5 connector type: 0:RJ-48C 1:BNC
1.3.6.1.4.1.4756.20.110.20.1.31Columnfa5e1et100E1Ch1RAILocalread-onlycurrent5E1-ET100(T/S) Series card E1 channel 1 RAI status: 0:No 1:Yes
1.3.6.1.4.1.4756.20.110.20.1.32Columnfa5e1et100E1Ch2RAILocalread-onlycurrent5E1-ET100(T/S) Series card E1 channel 2 RAI status: 0:No 1:Yes
1.3.6.1.4.1.4756.20.110.20.1.33Columnfa5e1et100E1Ch3RAILocalread-onlycurrent5E1-ET100(T/S) Series card E1 channel 3 RAI status: 0:No 1:Yes
1.3.6.1.4.1.4756.20.110.20.1.34Columnfa5e1et100E1Ch4RAILocalread-onlycurrent5E1-ET100(T/S) Series card E1 channel 4 RAI status: 0:No 1:Yes
1.3.6.1.4.1.4756.20.110.20.1.35Columnfa5e1et100E1Ch5RAILocalread-onlycurrent5E1-ET100(T/S) Series card E1 channel 5 RAI status: 0:No 1:Yes
1.3.6.1.4.1.4756.20.110.20.1.36Columnfa5e1et100E1Ch1LOMFLocalread-onlycurrent5E1-ET100(T/S) Series card E1 channel 1 LOMF status: 0:No 1:Yes
1.3.6.1.4.1.4756.20.110.20.1.37Columnfa5e1et100E1Ch2LOMFLocalread-onlycurrent5E1-ET100(T/S) Series card E1 channel 2 LOMF status: 0:No 1:Yes
1.3.6.1.4.1.4756.20.110.20.1.38Columnfa5e1et100E1Ch3LOMFLocalread-onlycurrent5E1-ET100(T/S) Series card E1 channel 3 LOMF status: 0:No 1:Yes
1.3.6.1.4.1.4756.20.110.20.1.39Columnfa5e1et100E1Ch4LOMFLocalread-onlycurrent5E1-ET100(T/S) Series card E1 channel 4 LOMF status: 0:No 1:Yes
1.3.6.1.4.1.4756.20.110.20.1.40Columnfa5e1et100E1Ch5LOMFLocalread-onlycurrent5E1-ET100(T/S) Series card E1 channel 5 LOMF status: 0:No 1:Yes
1.3.6.1.4.1.4756.20.110.20.1.41Columnfa5e1et100E1Ch1ActiveLocalread-onlycurrent5E1-ET100(T/S) Series card E1 channel 1 active status: 0:Inactive 1:Active
1.3.6.1.4.1.4756.20.110.20.1.42Columnfa5e1et100E1Ch2ActiveLocalread-onlycurrent5E1-ET100(T/S) Series card E1 channel 2 active status: 0:Inactive 1:Active
1.3.6.1.4.1.4756.20.110.20.1.43Columnfa5e1et100E1Ch3ActiveLocalread-onlycurrent5E1-ET100(T/S) Series card E1 channel 3 active status: 0:Inactive 1:Active
1.3.6.1.4.1.4756.20.110.20.1.44Columnfa5e1et100E1Ch4ActiveLocalread-onlycurrent5E1-ET100(T/S) Series card E1 channel 4 active status: 0:Inactive 1:Active
1.3.6.1.4.1.4756.20.110.20.1.45Columnfa5e1et100E1Ch5ActiveLocalread-onlycurrent5E1-ET100(T/S) Series card E1 channel 5 active status: 0:Inactive 1:Active
1.3.6.1.4.1.4756.20.110.20.1.46Columnfa5e1et100E1Ch1LoopBackLocalread-writecurrent5E1-ET100(T/S) Series card port E1 channel 1 loop back: 0:Off 2:RLB (Max used 4 channels)
1.3.6.1.4.1.4756.20.110.20.1.47Columnfa5e1et100E1Ch2LoopBackLocalread-writecurrent5E1-ET100(T/S) Series card port E1 channel 2 loop back: 0:Off 2:RLB (Max used 4 channels)
1.3.6.1.4.1.4756.20.110.20.1.48Columnfa5e1et100E1Ch3LoopBackLocalread-writecurrent5E1-ET100(T/S) Series card port E1 channel 3 loop back: 0:Off 2:RLB (Max used 4 channels)
1.3.6.1.4.1.4756.20.110.20.1.49Columnfa5e1et100E1Ch4LoopBackLocalread-writecurrent5E1-ET100(T/S) Series card port E1 channel 4 loop back: 0:Off 2:RLB (Max used 4 channels)
1.3.6.1.4.1.4756.20.110.20.1.50Columnfa5e1et100E1Ch5LoopBackLocalread-writecurrent5E1-ET100(T/S) Series card port E1 channel 5 loop back: 0:Off 2:RLB (Max used 4 channels)
1.3.6.1.4.1.4756.20.110.20.1.51Columnfa5e1et100FxLinkLocalread-onlycurrent5E1-ET100S Series card Fiber siganl detect status: 0:Down or Fiber unplugged 1:Up or Singal detected
1.3.6.1.4.1.4756.20.110.20.1.52Columnfa5e1et100FxLaserLocalread-onlycurrent5E1-ET100S Series card laser status: 0:Normal 1:Error
1.3.6.1.4.1.4756.20.110.20.1.53Columnfa5e1et100FxActiveLocalread-writecurrent5E1-ET100S Series card Fiber active: 0:Inactive 1:Active
1.3.6.1.4.1.4756.20.110.20.1.54Columnfa5e1et100FxLaserOutputLocalread-writecurrent5E1-ET100S Series card laser output: 0:disable 1:Enable
1.3.6.1.4.1.4756.20.110.20.1.55Columnfa5e1et100FxOpModeLocalread-writecurrent5E1-ET100S Series card operation mode: 0:Switch 1:Convert
1.3.6.1.4.1.4756.20.110.20.1.56Columnfa5e1et100UtpLinkLocalread-onlycurrent5E1-ET100T Series card UTP link status: 0:Link Down 1:Link Up
1.3.6.1.4.1.4756.20.110.20.1.57Columnfa5e1et100UtpStatusLocalread-onlycurrent5E1-ET100T Series card UTP link mode status: 0:None, Maybe link down 1:Link at 10Mbps, Half duplex 2:Link at 10Mbps, Full duplex 3:Link at 100Mbps, Half duplex…
1.3.6.1.4.1.4756.20.110.20.1.58Columnfa5e1et100UtpFlowCtrlStsLocalread-onlycurrent5E1-ET100T Series card UTP flow control status: 0:Disable 1:Enable
1.3.6.1.4.1.4756.20.110.20.1.59Columnfa5e1et100UtpModeLocalread-writecurrent5E1-ET100T Series card UTP mode: 0:Disable 1:Enable and autoNegotiation 3:Enable and force to 10Mbps, Half duplex 4:Enable and force to 10Mbps, Full duplex 5:E…
1.3.6.1.4.1.4756.20.110.20.1.60Columnfa5e1et100UtpFlowCtrlLocalread-writecurrent5E1-ET100T Series card UTP flow control: 0:Disable 1:Enable
1.3.6.1.4.1.4756.20.110.20.1.61Columnfa5e1et100SpeedLimitLocalread-writecurrent5E1-ET100(T/S) Series card speed limit: Limited = this value * 32Kbps, this value is restricted to 0 ~ 3125, 0 to disable
1.3.6.1.4.1.4756.20.110.20.1.62Columnfa5e1et100VlanAwareLocalread-writecurrent5E1-ET100(T/S) Series card 802.1q VLAN tag aware: 0:Disable 1:Enable
1.3.6.1.4.1.4756.20.110.20.1.63Columnfa5e1et100VlanIDLocalread-writecurrent5E1-ET100(T/S) Series card VLAN ID: The ID is restricted to 1 ~ 4094
1.3.6.1.4.1.4756.20.110.20.1.64Columnfa5e1et100RemoteDeviceLocalread-onlycurrentFRM220A-5E1 Series card remote device status: 0:Link Down 1:Link Up
1.3.6.1.4.1.4756.20.110.20.1.65Columnfa5e1et100RemotePowerLocalread-onlycurrent5E1-ET100(T/S) Series card remote device power status: 0:Normal 1:Power off
1.3.6.1.4.1.4756.20.110.20.1.66Columnfa5e1et100TimingSourceLocalread-writecurrent5E1-ET100(T/S) Series card clock: 0:Internal oscillatro 1:Recovery from E1 channel 1 2:Recovery from E1 channel 2 3:Recovery from E1 channel 3 4:Recovery from …
1.3.6.1.4.1.4756.20.110.20.1.67Columnfa5e1et100FCSofGFPLocalread-writecurrent5E1-ET100(T/S) Series card FCS of GFP: 0:Disable 1:Enable
1.3.6.1.4.1.4756.20.110.20.1.68Columnfa5e1et100AutoChAdjustLocalread-writecurrent5E1-ET100(T/S) Series card auto channel Bdjust: 0:Disable 1:Enable
1.3.6.1.4.1.4756.20.110.20.1.69Columnfa5e1et100PayloadScrambleLocalread-writecurrent5E1-ET100(T/S) Series card payload scramble: 0:Disable 1:Enable
1.3.6.1.4.1.4756.20.110.20.1.70Columnfa5e1et100FailoverLocalread-writecurrent5E1-ET100(T/S) Series card failover: 0:Disable 1:Enable
1.3.6.1.4.1.4756.20.110.20.1.71Columnfa5e1et100LOMLocalread-onlycurrent5E1-ET100(T/S) Series card LOM status: 0:No 1:Yes
1.3.6.1.4.1.4756.20.110.20.1.72Columnfa5e1et100SQMLocalread-onlycurrent5E1-ET100(T/S) Series card SQM status: 0:No 1:Yes
1.3.6.1.4.1.4756.20.110.20.1.73Columnfa5e1et100CRCLocalread-onlycurrent5E1-ET100(T/S) Series card CRC status: 0:No 1:Yes
1.3.6.1.4.1.4756.20.110.20.1.74Columnfa5e1et100LOALocalread-onlycurrent5E1-ET100(T/S) Series card LOA status: 0:No 1:Yes
1.3.6.1.4.1.4756.20.110.20.1.75Columnfa5e1et100LFDLocalread-onlycurrent5E1-ET100(T/S) Series card LFD status: 0:No 1:Yes
1.3.6.1.4.1.4756.20.110.20.1.76Columnfa5e1et100DDTOLocalread-onlycurrent5E1-ET100(T/S) Series card DDTO status: 0:No 1:Yes
1.3.6.1.4.1.4756.20.110.20.1.77Columnfa5e1et100VcatMember1Localread-writecurrent5E1-ET100(T/S) Series card VACT member 0: 0:Disable 1:Enable
1.3.6.1.4.1.4756.20.110.20.1.78Columnfa5e1et100VcatMember2Localread-writecurrent5E1-ET100(T/S) Series card VACT member 1: 0:Disable 1:Enable
1.3.6.1.4.1.4756.20.110.20.1.79Columnfa5e1et100VcatMember3Localread-writecurrent5E1-ET100(T/S) Series card VACT member 3: 0:Disable 1:Enable
1.3.6.1.4.1.4756.20.110.20.1.80Columnfa5e1et100VcatMember4Localread-writecurrent5E1-ET100(T/S) Series card VACT member 4: 0:Disable 1:Enable
1.3.6.1.4.1.4756.20.110.20.1.81Columnfa5e1et100VcatMember5Localread-writecurrent5E1-ET100(T/S) Series card VACT member 5: 0:Disable 1:Enable
1.3.6.1.4.1.4756.20.110.20.1.82Columnfa5e1et100SnmpChannel1Localread-writecurrent5E1-ET100(T/S) Series card SNMP channel 0: 0:No use 1:Use
1.3.6.1.4.1.4756.20.110.20.1.83Columnfa5e1et100SnmpChannel2Localread-writecurrent5E1-ET100(T/S) Series card SNMP channel 1: 0:No use 1:Use
1.3.6.1.4.1.4756.20.110.20.1.84Columnfa5e1et100SnmpChannel3Localread-writecurrent5E1-ET100(T/S) Series card SNMP channel 3: 0:No use 1:Use
1.3.6.1.4.1.4756.20.110.20.1.85Columnfa5e1et100SnmpChannel4Localread-writecurrent5E1-ET100(T/S) Series card SNMP channel 4: 0:No use 1:Use
1.3.6.1.4.1.4756.20.110.20.1.86Columnfa5e1et100ErrSecLocalread-onlycurrent5E1-ET100(T/S) Series card, errored seconds of BERT result.
1.3.6.1.4.1.4756.20.110.20.1.87Columnfa5e1et100ErrFreeSecLocalread-onlycurrent5E1-ET100(T/S) Series card, errored free seconds of BERT result.
1.3.6.1.4.1.4756.20.110.20.1.88Columnfa5e1et100ServErrSecLocalread-onlycurrent5E1-ET100(T/S) Series card, severely errored seconds of BERT result.
1.3.6.1.4.1.4756.20.110.20.1.89Columnfa5e1et100BertFunctionLocalread-writecurrent5E1-ET100(T/S) Series card bert function: 0:Disable 1:Enable
1.3.6.1.4.1.4756.20.110.20.1.90Columnfa5e1et100ClrBertDataLocalread-writecurrent5E1-ET100(T/S) Series card bert data clear: 0:Normal 1:Clear
1.3.6.1.4.1.4756.20.110.20.1.91Columnfa5e1et100BertE1ChannelLocalread-writecurrent5E1-ET100(T/S) Series card bert E1 channel number: 0:E1 channel 1 1:E1 channel 2 2:E1 channel 3 3:E1 channel 4 4:E1 channel 5
1.3.6.1.4.1.4756.20.110.20.1.92Columnfa5e1et100RmonFunctionLocalread-writecurrent5E1-ET100(T/S) Series RMON function : 0:Disable 1:Enable
1.3.6.1.4.1.4756.20.110.20.1.93Columnfa5e1et100RmonTxLocalread-onlycurrent5E1-ET100(T/S) Series card RMON Tx counter.
1.3.6.1.4.1.4756.20.110.20.1.94Columnfa5e1et100RmonRxLocalread-onlycurrent5E1-ET100(T/S) Series card RMON Rx counter.
1.3.6.1.4.1.4756.20.110.20.1.95Columnfa5e1et100ClrRmonTxLocalread-writecurrent5E1-ET100(T/S) Series card clear RMON Tx counter: 0:Normal 1:Clear
1.3.6.1.4.1.4756.20.110.20.1.96Columnfa5e1et100ClrRmonRxLocalread-writecurrent5E1-ET100(T/S) Series card clear RMON Rx counter: 0:Normal 1:Clear
1.3.6.1.4.1.4756.20.110.20.1.97Columnfa5e1et100SfpLocalread-onlycurrent5E1-ET100(T/S) Series card, SFP existed: 0:No 1:Yes
1.3.6.1.4.1.4756.20.110.20.1.98Columnfa5e1et100SfpVendorLocalread-onlycurrent5E1-ET100(T/S) Series card, Vendor name of SFP.
1.3.6.1.4.1.4756.20.110.20.1.99Columnfa5e1et100SfpPartNoLocalread-onlycurrent5E1-ET100(T/S) Series card, Vendor part number of SFP.
1.3.6.1.4.1.4756.20.110.20.1.100Columnfa5e1et100SfpFiberTypeLocalread-onlycurrent5E1-ET100(T/S) Series card, Fiber Type of SFP.
1.3.6.1.4.1.4756.20.110.20.1.101Columnfa5e1et100SfpTxWaveLenLocalread-onlycurrent5E1-ET100(T/S) Series card, Tx Wave length of SFP.
1.3.6.1.4.1.4756.20.110.20.1.102Columnfa5e1et100SfpRxWaveLenLocalread-onlycurrent5E1-ET100(T/S) Series card, Rx Wave length of SFP.
1.3.6.1.4.1.4756.20.110.20.1.103Columnfa5e1et100SfpLinkLenLocalread-onlycurrent5E1-ET100(T/S) Series card, Link length of SFP.
1.3.6.1.4.1.4756.20.110.20.1.104Columnfa5e1et100SfpModelIDLocalread-onlycurrent5E1-ET100(T/S) Series card, model ID of SFP.
1.3.6.1.4.1.4756.20.110.20.1.105Columnfa5e1et100SfpVersionLocalread-onlycurrent5E1-ET100(T/S) Series card, the version of SFP.
1.3.6.1.4.1.4756.20.110.20.1.106Columnfa5e1et100SfpModelTypeLocalread-onlycurrent5E1-ET100(T/S) Series card, model type of SFP.
1.3.6.1.4.1.4756.20.110.20.1.107Columnfa5e1et100DDInformationLocalread-onlycurrent5E1-ET100(T/S) Series card, D/D information of SFP Supported: 0:No, 1:Yes
1.3.6.1.4.1.4756.20.110.20.1.108Columnfa5e1et100DDRxSensLocalread-onlycurrent5E1-ET100(T/S) Series card, Sensitivity of D/D information.
1.3.6.1.4.1.4756.20.110.20.1.109Columnfa5e1et100DDTxPowerLocalread-onlycurrent5E1-ET100(T/S) Series card, Tx power of D/D information.
1.3.6.1.4.1.4756.20.110.20.1.110Columnfa5e1et100DDRxPowerLocalread-onlycurrent5E1-ET100(T/S) Series card, Rx power of D/D information.
1.3.6.1.4.1.4756.20.110.20.1.111Columnfa5e1et100DDTempLocalread-onlycurrent5E1-ET100(T/S) Series card, Temperature of D/D information in degree C.
1.3.6.1.4.1.4756.20.110.20.1.112Columnfa5e1et100DDBiasLocalread-onlycurrent5E1-ET100(T/S) Series card, BIAS of D/D information.
1.3.6.1.4.1.4756.20.110.20.1.113Columnfa5e1et100DDVoltageLocalread-onlycurrent5E1-ET100(T/S) Series card, Voltage of D/D information.
1.3.6.1.4.1.4756.20.110.20.1.114Columnfa5e1et100ChannelDefectLocalread-writecurrent5E1-ET100(T/S) Series card Channel Defect: 0:Disable 4:1E-4 6:1E-6
1.3.6.1.4.1.4756.20.110.20.1.115Columnfa5e1et100LoopDetectionLocalread-writecurrent5E1-ET100(T/S) Series card Loop Detection: 0:Disable 1:Enable
1.3.6.1.4.1.4756.20.110.20.1.116Columnfa5e1et100LoopCh1Localread-onlycurrent5E1-ET100(T/S) Series card E1 channel 1 Loop Check State: 0:No 1:Yes
1.3.6.1.4.1.4756.20.110.20.1.117Columnfa5e1et100LoopCh2Localread-onlycurrent5E1-ET100(T/S) Series card E1 channel 2 Loop Check State: 0:No 1:Yes
1.3.6.1.4.1.4756.20.110.20.1.118Columnfa5e1et100LoopCh3Localread-onlycurrent5E1-ET100(T/S) Series card E1 channel 3 Loop Check State: 0:No 1:Yes
1.3.6.1.4.1.4756.20.110.20.1.119Columnfa5e1et100LoopCh4Localread-onlycurrent5E1-ET100(T/S) Series card E1 channel 4 Loop Check State: 0:No 1:Yes
1.3.6.1.4.1.4756.20.110.20.1.120Columnfa5e1et100LoopCh5Localread-onlycurrent5E1-ET100(T/S) Series card E1 channel 5 Loop Check State: 0:No 1:Yes
1.3.6.1.4.1.4756.20.110.20.1.121Columnfa5e1et100DefectCh1Localread-onlycurrent5E1-ET100(T/S) Series card E1 channel 1 Defect Status: 0:No 1:Yes
1.3.6.1.4.1.4756.20.110.20.1.122Columnfa5e1et100DefectCh2Localread-onlycurrent5E1-ET100(T/S) Series card E1 channel 2 Defect Status: 0:No 1:Yes
1.3.6.1.4.1.4756.20.110.20.1.123Columnfa5e1et100DefectCh3Localread-onlycurrent5E1-ET100(T/S) Series card E1 channel 3 Defect Status: 0:No 1:Yes
1.3.6.1.4.1.4756.20.110.20.1.124Columnfa5e1et100DefectCh4Localread-onlycurrent5E1-ET100(T/S) Series card E1 channel 4 Defect Status: 0:No 1:Yes
1.3.6.1.4.1.4756.20.110.20.1.125Columnfa5e1et100DefectCh5Localread-onlycurrent5E1-ET100(T/S) Series card E1 channel 5 Defect Status: 0:No 1:Yes
1.3.6.1.4.1.4756.20.110.20.1.126Columnfa5e1et100FxSignalLocalread-onlycurrent5E1-ET100(T/S) Series card Fiber signal detect(SD): 0:Fiber unplugged 1:Signal detected
1.3.6.1.4.1.4756.20.110.20.1.127Columnfa5e1et100PortResetLocalread-writecurrent5E1-ET100(T/S) Series card Port Reset: 0:Off 1:Action
1.3.6.1.4.1.4756.20.110.20.1.128Columnfa5e1et100VLANModeLocalread-writecurrent5E1-ET100(T/S) Series card VLAN mode: 0:MODE2 1:MODE1
1.3.6.1.4.1.4756.20.110.20.1.129Columnfa5e1et100ETagSelectEntryLocalread-writecurrent5E1-ET100(T/S) Series card ETag select entry:
1.3.6.1.4.1.4756.20.110.20.1.130Columnfa5e1et100ETagMethodLocalread-writecurrent5E1-ET100(T/S) Series card ETag Method: 0: Intouch 1: Add Tag 2: Remove Tag
1.3.6.1.4.1.4756.20.110.20.1.131Columnfa5e1et100VLANTableVID1Localread-writecurrent5E1-ET100(T/S) Series card VLAN Table: VLAN ID1
1.3.6.1.4.1.4756.20.110.20.1.132Columnfa5e1et100VLANTableVID2Localread-writecurrent5E1-ET100(T/S) Series card VLAN Table: VLAN ID2
1.3.6.1.4.1.4756.20.110.20.1.133Columnfa5e1et100VLANTableVID3Localread-writecurrent5E1-ET100(T/S) Series card VLAN Table: VLAN ID3
1.3.6.1.4.1.4756.20.110.20.1.134Columnfa5e1et100VLANTableVID4Localread-writecurrent5E1-ET100(T/S) Series card VLAN Table: VLAN ID4
1.3.6.1.4.1.4756.20.110.20.1.135Columnfa5e1et100VLANTableVID5Localread-writecurrent5E1-ET100(T/S) Series card VLAN Table: VLAN ID5
1.3.6.1.4.1.4756.20.110.20.1.136Columnfa5e1et100VLANTableVID6Localread-writecurrent5E1-ET100(T/S) Series card VLAN Table: VLAN ID6
1.3.6.1.4.1.4756.20.110.20.1.137Columnfa5e1et100VLANTableVID7Localread-writecurrent5E1-ET100(T/S) Series card VLAN Table: VLAN ID7
1.3.6.1.4.1.4756.20.110.20.1.138Columnfa5e1et100VLANTableVID8Localread-writecurrent5E1-ET100(T/S) Series card VLAN Table: VLAN ID8
1.3.6.1.4.1.4756.20.110.20.1.139Columnfa5e1et100VLANTableVID9Localread-writecurrent5E1-ET100(T/S) Series card VLAN Table: VLAN ID9
1.3.6.1.4.1.4756.20.110.20.1.140Columnfa5e1et100VLANTableVID10Localread-writecurrent5E1-ET100(T/S) Series card VLAN Table: VLAN ID10
1.3.6.1.4.1.4756.20.110.20.1.141Columnfa5e1et100VLANTableVID11Localread-writecurrent5E1-ET100(T/S) Series card VLAN Table: VLAN ID11
1.3.6.1.4.1.4756.20.110.20.1.142Columnfa5e1et100VLANTableVID12Localread-writecurrent5E1-ET100(T/S) Series card VLAN Table: VLAN ID12
1.3.6.1.4.1.4756.20.110.20.1.143Columnfa5e1et100VLANTableVID13Localread-writecurrent5E1-ET100(T/S) Series card VLAN Table: VLAN ID13
1.3.6.1.4.1.4756.20.110.20.1.144Columnfa5e1et100VLANTableVID14Localread-writecurrent5E1-ET100(T/S) Series card VLAN Table: VLAN ID14
1.3.6.1.4.1.4756.20.110.20.1.145Columnfa5e1et100VLANTableVID15Localread-writecurrent5E1-ET100(T/S) Series card VLAN Table: VLAN ID15
1.3.6.1.4.1.4756.20.110.20.1.146Columnfa5e1et100VLANTableVID16Localread-writecurrent5E1-ET100(T/S) Series card VLAN Table: VLAN ID16
1.3.6.1.4.1.4756.20.111Nodef5E1RemoteCards
1.3.6.1.4.1.4756.20.111.20Tablef5E1RemoteTablenot-accessiblecurrentA list of local FRM220-5E1-ET100 series card entries. The number of entries is f5E1-No-R.
1.3.6.1.4.1.4756.20.111.20.1Rowf5E1RemoteEntrynot-accessiblecurrentAn entry containing management information applicable to a particular local FRM220-5E1 series card.
1.3.6.1.4.1.4756.20.111.20.1.1Columnfa5e1et100ChassisIndexRemoteread-onlycurrentA unique value for each card. It starts from 0 to 9 contiguously.
1.3.6.1.4.1.4756.20.111.20.1.2Columnfa5e1et100SlotIndexRemoteread-onlycurrentA unique value for each card. It starts from 1 to 20 contiguously.
1.3.6.1.4.1.4756.20.111.20.1.3Columnfa5e1et100CardHWVerRemoteread-onlycurrent5E1-ET100(T/S) Series card hardware version x.xxx
1.3.6.1.4.1.4756.20.111.20.1.4Columnfa5e1et100CardFWVerRemoteread-onlycurrent5E1-ET100(T/S) Series card firmware version x.xxx
1.3.6.1.4.1.4756.20.111.20.1.5Columnfa5e1et100CardCPLDVerRemoteread-onlycurrent5E1-ET100(T/S) Series card CPLD version x.xxx
1.3.6.1.4.1.4756.20.111.20.1.6Columnfa5e1et100CardFPGAVerRemoteread-onlycurrent5E1-ET100(T/S) Series card FPGA version x.xxx
1.3.6.1.4.1.4756.20.111.20.1.7Columnfa5e1et100ModelRemoteread-onlycurrentCard Type: 0:5E1-ET100T 1:5E1-ET100S
1.3.6.1.4.1.4756.20.111.20.1.8Columnfa5e1et100SystemStatusRemoteread-onlycurrent5E1-ET100(T/S) Series card system status: 0:Normal 1:Alarm
1.3.6.1.4.1.4756.20.111.20.1.9Columnfa5e1et100DeviceActiveRemoteread-onlycurrent5E1-ET100(T/S) Series card active: 0:Disable 1:Enable
1.3.6.1.4.1.4756.20.111.20.1.10Columnfa5e1et100SetToDefaultRemoteread-writecurrent5E1-ET100(T/S) Series card port set to default: 0:Off 1:Trigger
1.3.6.1.4.1.4756.20.111.20.1.11Columnfa5e1et100E1Ch1SingalRemoteread-onlycurrent5E1-ET100(T/S) Series card E1 channel 1 signal status: 0:Singal Loss 1:Normal
1.3.6.1.4.1.4756.20.111.20.1.12Columnfa5e1et100E1Ch2SingalRemoteread-onlycurrent5E1-ET100(T/S) Series card E1 channel 2 signal status: 0:Singal Loss 1:Normal
1.3.6.1.4.1.4756.20.111.20.1.13Columnfa5e1et100E1Ch3SingalRemoteread-onlycurrent5E1-ET100(T/S) Series card E1 channel 3 signal status: 0:Singal Loss 1:Normal
1.3.6.1.4.1.4756.20.111.20.1.14Columnfa5e1et100E1Ch4SingalRemoteread-onlycurrent5E1-ET100(T/S) Series card E1 channel 4 signal status: 0:Singal Loss 1:Normal
1.3.6.1.4.1.4756.20.111.20.1.15Columnfa5e1et100E1Ch5SingalRemoteread-onlycurrent5E1-ET100(T/S) Series card E1 channel 5 signal status: 0:Singal Loss 1:Normal
1.3.6.1.4.1.4756.20.111.20.1.16Columnfa5e1et100E1Ch1SyncRemoteread-onlycurrent5E1-ET100(T/S) Series card E1 channel 1 sync status: 0:Sync Loss 1:Sync
1.3.6.1.4.1.4756.20.111.20.1.17Columnfa5e1et100E1Ch2SyncRemoteread-onlycurrent5E1-ET100(T/S) Series card E1 channel 2 sync status: 0:Sync Loss 1:Sync
1.3.6.1.4.1.4756.20.111.20.1.18Columnfa5e1et100E1Ch3SyncRemoteread-onlycurrent5E1-ET100(T/S) Series card E1 channel 3 sync status: 0:Sync Loss 1:Sync
1.3.6.1.4.1.4756.20.111.20.1.19Columnfa5e1et100E1Ch4SyncRemoteread-onlycurrent5E1-ET100(T/S) Series card E1 channel 4 sync status: 0:Sync Loss 1:Sync
1.3.6.1.4.1.4756.20.111.20.1.20Columnfa5e1et100E1Ch5SyncRemoteread-onlycurrent5E1-ET100(T/S) Series card E1 channel 5 sync status: 0:Sync Loss 1:Sync
1.3.6.1.4.1.4756.20.111.20.1.21Columnfa5e1et100E1Ch1RecvAISRemoteread-onlycurrent5E1-ET100(T/S) Series card E1 channel 1 receive AIS status: 0:No 1:Yes
1.3.6.1.4.1.4756.20.111.20.1.22Columnfa5e1et100E1Ch2RecvAISRemoteread-onlycurrent5E1-ET100(T/S) Series card E1 channel 2 receive AIS status: 0:No 1:Yes
1.3.6.1.4.1.4756.20.111.20.1.23Columnfa5e1et100E1Ch3RecvAISRemoteread-onlycurrent5E1-ET100(T/S) Series card E1 channel 3 receive AIS status: 0:No 1:Yes
1.3.6.1.4.1.4756.20.111.20.1.24Columnfa5e1et100E1Ch4RecvAISRemoteread-onlycurrent5E1-ET100(T/S) Series card E1 channel 4 receive AIS status: 0:No 1:Yes
1.3.6.1.4.1.4756.20.111.20.1.25Columnfa5e1et100E1Ch5RecvAISRemoteread-onlycurrent5E1-ET100(T/S) Series card E1 channel 5 receive AIS status: 0:No 1:Yes
1.3.6.1.4.1.4756.20.111.20.1.26Columnfa5e1et100E1Ch1ConnTypeRemoteread-onlycurrent5E1-ET100(T/S) Series card E1 channel 1 connector type: 0:RJ-48C 1:BNC
1.3.6.1.4.1.4756.20.111.20.1.27Columnfa5e1et100E1Ch2ConnTypeRemoteread-onlycurrent5E1-ET100(T/S) Series card E1 channel 2 connector type: 0:RJ-48C 1:BNC
1.3.6.1.4.1.4756.20.111.20.1.28Columnfa5e1et100E1Ch3ConnTypeRemoteread-onlycurrent5E1-ET100(T/S) Series card E1 channel 3 connector type: 0:RJ-48C 1:BNC
1.3.6.1.4.1.4756.20.111.20.1.29Columnfa5e1et100E1Ch4ConnTypeRemoteread-onlycurrent5E1-ET100(T/S) Series card E1 channel 4 connector type: 0:RJ-48C 1:BNC
1.3.6.1.4.1.4756.20.111.20.1.30Columnfa5e1et100E1Ch5ConnTypeRemoteread-onlycurrent5E1-ET100(T/S) Series card E1 channel 5 connector type: 0:RJ-48C 1:BNC
1.3.6.1.4.1.4756.20.111.20.1.31Columnfa5e1et100E1Ch1RAIRemoteread-onlycurrent5E1-ET100(T/S) Series card E1 channel 1 RAI status: 0:No 1:Yes
1.3.6.1.4.1.4756.20.111.20.1.32Columnfa5e1et100E1Ch2RAIRemoteread-onlycurrent5E1-ET100(T/S) Series card E1 channel 2 RAI status: 0:No 1:Yes
1.3.6.1.4.1.4756.20.111.20.1.33Columnfa5e1et100E1Ch3RAIRemoteread-onlycurrent5E1-ET100(T/S) Series card E1 channel 3 RAI status: 0:No 1:Yes
1.3.6.1.4.1.4756.20.111.20.1.34Columnfa5e1et100E1Ch4RAIRemoteread-onlycurrent5E1-ET100(T/S) Series card E1 channel 4 RAI status: 0:No 1:Yes
1.3.6.1.4.1.4756.20.111.20.1.35Columnfa5e1et100E1Ch5RAIRemoteread-onlycurrent5E1-ET100(T/S) Series card E1 channel 5 RAI status: 0:No 1:Yes
1.3.6.1.4.1.4756.20.111.20.1.36Columnfa5e1et100E1Ch1LOMFRemoteread-onlycurrent5E1-ET100(T/S) Series card E1 channel 1 LOMF status: 0:No 1:Yes
1.3.6.1.4.1.4756.20.111.20.1.37Columnfa5e1et100E1Ch2LOMFRemoteread-onlycurrent5E1-ET100(T/S) Series card E1 channel 2 LOMF status: 0:No 1:Yes
1.3.6.1.4.1.4756.20.111.20.1.38Columnfa5e1et100E1Ch3LOMFRemoteread-onlycurrent5E1-ET100(T/S) Series card E1 channel 3 LOMF status: 0:No 1:Yes
1.3.6.1.4.1.4756.20.111.20.1.39Columnfa5e1et100E1Ch4LOMFRemoteread-onlycurrent5E1-ET100(T/S) Series card E1 channel 4 LOMF status: 0:No 1:Yes
1.3.6.1.4.1.4756.20.111.20.1.40Columnfa5e1et100E1Ch5LOMFRemoteread-onlycurrent5E1-ET100(T/S) Series card E1 channel 5 LOMF status: 0:No 1:Yes
1.3.6.1.4.1.4756.20.111.20.1.41Columnfa5e1et100E1Ch1ActiveRemoteread-onlycurrent5E1-ET100(T/S) Series card E1 channel 1 active status: 0:Inactive 1:Active
1.3.6.1.4.1.4756.20.111.20.1.42Columnfa5e1et100E1Ch2ActiveRemoteread-onlycurrent5E1-ET100(T/S) Series card E1 channel 2 active status: 0:Inactive 1:Active
1.3.6.1.4.1.4756.20.111.20.1.43Columnfa5e1et100E1Ch3ActiveRemoteread-onlycurrent5E1-ET100(T/S) Series card E1 channel 3 active status: 0:Inactive 1:Active
1.3.6.1.4.1.4756.20.111.20.1.44Columnfa5e1et100E1Ch4ActiveRemoteread-onlycurrent5E1-ET100(T/S) Series card E1 channel 4 active status: 0:Inactive 1:Active
1.3.6.1.4.1.4756.20.111.20.1.45Columnfa5e1et100E1Ch5ActiveRemoteread-onlycurrent5E1-ET100(T/S) Series card E1 channel 5 active status: 0:Inactive 1:Active
1.3.6.1.4.1.4756.20.111.20.1.46Columnfa5e1et100E1Ch1LoopBackRemoteread-writecurrent5E1-ET100(T/S) Series card port E1 channel 1 loop back: 0:Off 2:RLB (Max used 4 channels)
1.3.6.1.4.1.4756.20.111.20.1.47Columnfa5e1et100E1Ch2LoopBackRemoteread-writecurrent5E1-ET100(T/S) Series card port E1 channel 2 loop back: 0:Off 2:RLB (Max used 4 channels)
1.3.6.1.4.1.4756.20.111.20.1.48Columnfa5e1et100E1Ch3LoopBackRemoteread-writecurrent5E1-ET100(T/S) Series card port E1 channel 3 loop back: 0:Off 2:RLB (Max used 4 channels)
1.3.6.1.4.1.4756.20.111.20.1.49Columnfa5e1et100E1Ch4LoopBackRemoteread-writecurrent5E1-ET100(T/S) Series card port E1 channel 4 loop back: 0:Off 2:RLB (Max used 4 channels)
1.3.6.1.4.1.4756.20.111.20.1.50Columnfa5e1et100E1Ch5LoopBackRemoteread-writecurrent5E1-ET100(T/S) Series card port E1 channel 5 loop back: 0:Off 2:RLB (Max used 4 channels)
1.3.6.1.4.1.4756.20.111.20.1.51Columnfa5e1et100FxLinkRemoteread-onlycurrent5E1-ET100S Series card Fiber siganl detect status: 0:Down or Fiber unplugged 1:Up or Singal detected
1.3.6.1.4.1.4756.20.111.20.1.52Columnfa5e1et100FxLaserRemoteread-onlycurrent5E1-ET100S Series card laser status: 0:Normal 1:Error
1.3.6.1.4.1.4756.20.111.20.1.53Columnfa5e1et100FxActiveRemoteread-writecurrent5E1-ET100S Series card Fiber active: 0:Inactive 1:Active
1.3.6.1.4.1.4756.20.111.20.1.54Columnfa5e1et100FxLaserOutputRemoteread-writecurrent5E1-ET100S Series card laser output: 0:disable 1:Enable
1.3.6.1.4.1.4756.20.111.20.1.55Columnfa5e1et100FxOpModeRemoteread-writecurrent5E1-ET100S Series card operation mode: 0:Switch 1:Convert
1.3.6.1.4.1.4756.20.111.20.1.56Columnfa5e1et100UtpLinkRemoteread-onlycurrent5E1-ET100T Series card UTP link status: 0:Link Down 1:Link Up
1.3.6.1.4.1.4756.20.111.20.1.57Columnfa5e1et100UtpStatusRemoteread-onlycurrent5E1-ET100T Series card UTP link mode status: 0:None, Maybe link down 1:Link at 10Mbps, Half duplex 2:Link at 10Mbps, Full duplex 3:Link at 100Mbps, Half duplex…
1.3.6.1.4.1.4756.20.111.20.1.58Columnfa5e1et100UtpFlowCtrlStsRemoteread-onlycurrent5E1-ET100T Series card UTP flow control status: 0:Disable 1:Enable
1.3.6.1.4.1.4756.20.111.20.1.59Columnfa5e1et100UtpModeRemoteread-writecurrent5E1-ET100T Series card UTP mode: 0:Disable 1:Enable and autoNegotiation 3:Enable and force to 10Mbps, Half duplex 4:Enable and force to 10Mbps, Full duplex 5:E…
1.3.6.1.4.1.4756.20.111.20.1.60Columnfa5e1et100UtpFlowCtrlRemoteread-writecurrent5E1-ET100T Series card UTP flow control: 0:Disable 1:Enable
1.3.6.1.4.1.4756.20.111.20.1.61Columnfa5e1et100SpeedLimitRemoteread-writecurrent5E1-ET100(T/S) Series card speed limit: Limited = this value * 32Kbps, this value is restricted to 0 ~ 3125, 0 to disable
1.3.6.1.4.1.4756.20.111.20.1.62Columnfa5e1et100VlanAwareRemoteread-writecurrent5E1-ET100(T/S) Series card 802.1q VLAN tag aware: 0:Disable 1:Enable
1.3.6.1.4.1.4756.20.111.20.1.63Columnfa5e1et100VlanIDRemoteread-writecurrent5E1-ET100(T/S) Series card VLAN ID: The ID is restricted to 1 ~ 4094
1.3.6.1.4.1.4756.20.111.20.1.64Columnfa5e1et100RemoteDeviceRemoteread-onlycurrentFRM220A-5E1 Series card remote device status: 0:Link Down 1:Link Up
1.3.6.1.4.1.4756.20.111.20.1.65Columnfa5e1et100RemotePowerRemoteread-onlycurrent5E1-ET100(T/S) Series card remote device power status: 0:Normal 1:Power off
1.3.6.1.4.1.4756.20.111.20.1.66Columnfa5e1et100TimingSourceRemoteread-writecurrent5E1-ET100(T/S) Series card clock: 0:Internal oscillatro 1:Recovery from E1 channel 1 2:Recovery from E1 channel 2 3:Recovery from E1 channel 3 4:Recovery from …
1.3.6.1.4.1.4756.20.111.20.1.67Columnfa5e1et100FCSofGFPRemoteread-writecurrent5E1-ET100(T/S) Series card FCS of GFP: 0:Disable 1:Enable
1.3.6.1.4.1.4756.20.111.20.1.68Columnfa5e1et100AutoChAdjustRemoteread-writecurrent5E1-ET100(T/S) Series card auto channel Bdjust: 0:Disable 1:Enable
1.3.6.1.4.1.4756.20.111.20.1.69Columnfa5e1et100PayloadScrambleRemoteread-writecurrent5E1-ET100(T/S) Series card payload scramble: 0:Disable 1:Enable
1.3.6.1.4.1.4756.20.111.20.1.70Columnfa5e1et100FailoverRemoteread-writecurrent5E1-ET100(T/S) Series card failover: 0:Disable 1:Enable
1.3.6.1.4.1.4756.20.111.20.1.71Columnfa5e1et100LOMRemoteread-onlycurrent5E1-ET100(T/S) Series card LOM status: 0:No 1:Yes
1.3.6.1.4.1.4756.20.111.20.1.72Columnfa5e1et100SQMRemoteread-onlycurrent5E1-ET100(T/S) Series card SQM status: 0:No 1:Yes
1.3.6.1.4.1.4756.20.111.20.1.73Columnfa5e1et100CRCRemoteread-onlycurrent5E1-ET100(T/S) Series card CRC status: 0:No 1:Yes
1.3.6.1.4.1.4756.20.111.20.1.74Columnfa5e1et100LOARemoteread-onlycurrent5E1-ET100(T/S) Series card LOA status: 0:No 1:Yes
1.3.6.1.4.1.4756.20.111.20.1.75Columnfa5e1et100LFDRemoteread-onlycurrent5E1-ET100(T/S) Series card LFD status: 0:No 1:Yes
1.3.6.1.4.1.4756.20.111.20.1.76Columnfa5e1et100DDTORemoteread-onlycurrent5E1-ET100(T/S) Series card DDTO status: 0:No 1:Yes
1.3.6.1.4.1.4756.20.111.20.1.77Columnfa5e1et100VcatMember1Remoteread-writecurrent5E1-ET100(T/S) Series card VACT member 0: 0:Disable 1:Enable
1.3.6.1.4.1.4756.20.111.20.1.78Columnfa5e1et100VcatMember2Remoteread-writecurrent5E1-ET100(T/S) Series card VACT member 1: 0:Disable 1:Enable
1.3.6.1.4.1.4756.20.111.20.1.79Columnfa5e1et100VcatMember3Remoteread-writecurrent5E1-ET100(T/S) Series card VACT member 3: 0:Disable 1:Enable
1.3.6.1.4.1.4756.20.111.20.1.80Columnfa5e1et100VcatMember4Remoteread-writecurrent5E1-ET100(T/S) Series card VACT member 4: 0:Disable 1:Enable
1.3.6.1.4.1.4756.20.111.20.1.81Columnfa5e1et100VcatMember5Remoteread-writecurrent5E1-ET100(T/S) Series card VACT member 5: 0:Disable 1:Enable
1.3.6.1.4.1.4756.20.111.20.1.82Columnfa5e1et100SnmpChannel1Remoteread-writecurrent5E1-ET100(T/S) Series card SNMP channel 0: 0:No use 1:Use
1.3.6.1.4.1.4756.20.111.20.1.83Columnfa5e1et100SnmpChannel2Remoteread-writecurrent5E1-ET100(T/S) Series card SNMP channel 1: 0:No use 1:Use
1.3.6.1.4.1.4756.20.111.20.1.84Columnfa5e1et100SnmpChannel3Remoteread-writecurrent5E1-ET100(T/S) Series card SNMP channel 3: 0:No use 1:Use
1.3.6.1.4.1.4756.20.111.20.1.85Columnfa5e1et100SnmpChannel4Remoteread-writecurrent5E1-ET100(T/S) Series card SNMP channel 4: 0:No use 1:Use
1.3.6.1.4.1.4756.20.111.20.1.86Columnfa5e1et100ErrSecRemoteread-onlycurrent5E1-ET100(T/S) Series card, errored seconds of BERT result.
1.3.6.1.4.1.4756.20.111.20.1.87Columnfa5e1et100ErrFreeSecRemoteread-onlycurrent5E1-ET100(T/S) Series card, errored free seconds of BERT result.
1.3.6.1.4.1.4756.20.111.20.1.88Columnfa5e1et100ServErrSecRemoteread-onlycurrent5E1-ET100(T/S) Series card, severely errored seconds of BERT result.
1.3.6.1.4.1.4756.20.111.20.1.89Columnfa5e1et100BertFunctionRemoteread-writecurrent5E1-ET100(T/S) Series card bert function: 0:Disable 1:Enable
1.3.6.1.4.1.4756.20.111.20.1.90Columnfa5e1et100ClrBertDataRemoteread-writecurrent5E1-ET100(T/S) Series card bert data clear: 0:Normal 1:Clear
1.3.6.1.4.1.4756.20.111.20.1.91Columnfa5e1et100RmonFunctionRemoteread-writecurrent5E1-ET100(T/S) Series RMON function : 0:Disable 1:Enable
1.3.6.1.4.1.4756.20.111.20.1.92Columnfa5e1et100RmonTxRemoteread-onlycurrent5E1-ET100(T/S) Series card RMON Tx counter.
1.3.6.1.4.1.4756.20.111.20.1.93Columnfa5e1et100RmonRxRemoteread-onlycurrent5E1-ET100(T/S) Series card RMON Rx counter.
1.3.6.1.4.1.4756.20.111.20.1.94Columnfa5e1et100ClrRmonTxRemoteread-writecurrent5E1-ET100(T/S) Series card clear RMON Tx counter: 0:Normal 1:Clear
1.3.6.1.4.1.4756.20.111.20.1.95Columnfa5e1et100ClrRmonRxRemoteread-writecurrent5E1-ET100(T/S) Series card clear RMON Rx counter: 0:Normal 1:Clear
1.3.6.1.4.1.4756.20.111.20.1.96Columnfa5e1et100BertE1ChannelRemoteread-writecurrent5E1-ET100(T/S) Series card bert E1 channel number: 0:E1 channel 1 1:E1 channel 2 2:E1 channel 3 3:E1 channel 4 4:E1 channel 5
1.3.6.1.4.1.4756.20.111.20.1.97Columnfa5e1et100SfpRemoteread-onlycurrent5E1-ET100(T/S) Series card, SFP existed: 0:No 1:Yes
1.3.6.1.4.1.4756.20.111.20.1.98Columnfa5e1et100SfpVendorRemoteread-onlycurrent5E1-ET100(T/S) Series card, Vendor name of SFP.
1.3.6.1.4.1.4756.20.111.20.1.99Columnfa5e1et100SfpPartNoRemoteread-onlycurrent5E1-ET100(T/S) Series card, Vendor part number of SFP.
1.3.6.1.4.1.4756.20.111.20.1.100Columnfa5e1et100SfpFiberTypeRemoteread-onlycurrent5E1-ET100(T/S) Series card, Fiber Type of SFP.
1.3.6.1.4.1.4756.20.111.20.1.101Columnfa5e1et100SfpTxWaveLenRemoteread-onlycurrent5E1-ET100(T/S) Series card, Tx Wave length of SFP.
1.3.6.1.4.1.4756.20.111.20.1.102Columnfa5e1et100SfpRxWaveLenRemoteread-onlycurrent5E1-ET100(T/S) Series card, Rx Wave length of SFP.
1.3.6.1.4.1.4756.20.111.20.1.103Columnfa5e1et100SfpLinkLenRemoteread-onlycurrent5E1-ET100(T/S) Series card, Link length of SFP.
1.3.6.1.4.1.4756.20.111.20.1.104Columnfa5e1et100SfpModelIDRemoteread-onlycurrent5E1-ET100(T/S) Series card, model ID of SFP.
1.3.6.1.4.1.4756.20.111.20.1.105Columnfa5e1et100SfpVersionRemoteread-onlycurrent5E1-ET100(T/S) Series card, the version of SFP.
1.3.6.1.4.1.4756.20.111.20.1.106Columnfa5e1et100SfpModelTypeRemoteread-onlycurrent5E1-ET100(T/S) Series card, model type of SFP.
1.3.6.1.4.1.4756.20.111.20.1.107Columnfa5e1et100DDInformationRemoteread-onlycurrent5E1-ET100(T/S) Series card, D/D information of SFP Supported: 0:No, 1:Yes
1.3.6.1.4.1.4756.20.111.20.1.108Columnfa5e1et100DDRxSensRemoteread-onlycurrent5E1-ET100(T/S) Series card, Sensitivity of D/D information.
1.3.6.1.4.1.4756.20.111.20.1.109Columnfa5e1et100DDTxPowerRemoteread-onlycurrent5E1-ET100(T/S) Series card, Tx power of D/D information.
1.3.6.1.4.1.4756.20.111.20.1.110Columnfa5e1et100DDRxPowerRemoteread-onlycurrent5E1-ET100(T/S) Series card, Rx power of D/D information.
1.3.6.1.4.1.4756.20.111.20.1.111Columnfa5e1et100DDTempRemoteread-onlycurrent5E1-ET100(T/S) Series card, Temperature of D/D information in degree C.
1.3.6.1.4.1.4756.20.111.20.1.112Columnfa5e1et100DDBiasRemoteread-onlycurrent5E1-ET100(T/S) Series card, BIAS of D/D information.
1.3.6.1.4.1.4756.20.111.20.1.113Columnfa5e1et100DDVoltageRemoteread-onlycurrent5E1-ET100(T/S) Series card, Voltage of D/D information.
1.3.6.1.4.1.4756.20.111.20.1.114Columnfa5e1et100ChannelDefectRemoteread-writecurrent5E1-ET100(T/S) Series card Channel Defect: 0:Disable 4:1E-4 6:1E-6
1.3.6.1.4.1.4756.20.111.20.1.115Columnfa5e1et100LoopDetectionRemoteread-writecurrent5E1-ET100(T/S) Series card Loop Detection: 0:Disable 1:Enable
1.3.6.1.4.1.4756.20.111.20.1.116Columnfa5e1et100LoopCh1Remoteread-onlycurrent5E1-ET100(T/S) Series card E1 channel 1 Loop Check State: 0:No 1:Yes
1.3.6.1.4.1.4756.20.111.20.1.117Columnfa5e1et100LoopCh2Remoteread-onlycurrent5E1-ET100(T/S) Series card E1 channel 2 Loop Check State: 0:No 1:Yes
1.3.6.1.4.1.4756.20.111.20.1.118Columnfa5e1et100LoopCh3Remoteread-onlycurrent5E1-ET100(T/S) Series card E1 channel 3 Loop Check State: 0:No 1:Yes
1.3.6.1.4.1.4756.20.111.20.1.119Columnfa5e1et100LoopCh4Remoteread-onlycurrent5E1-ET100(T/S) Series card E1 channel 4 Loop Check State: 0:No 1:Yes
1.3.6.1.4.1.4756.20.111.20.1.120Columnfa5e1et100LoopCh5Remoteread-onlycurrent5E1-ET100(T/S) Series card E1 channel 5 Loop Check State: 0:No 1:Yes
1.3.6.1.4.1.4756.20.111.20.1.121Columnfa5e1et100DefectCh1Remoteread-onlycurrent5E1-ET100(T/S) Series card E1 channel 1 Defect Status: 0:No 1:Yes
1.3.6.1.4.1.4756.20.111.20.1.122Columnfa5e1et100DefectCh2Remoteread-onlycurrent5E1-ET100(T/S) Series card E1 channel 2 Defect Status: 0:No 1:Yes
1.3.6.1.4.1.4756.20.111.20.1.123Columnfa5e1et100DefectCh3Remoteread-onlycurrent5E1-ET100(T/S) Series card E1 channel 3 Defect Status: 0:No 1:Yes
1.3.6.1.4.1.4756.20.111.20.1.124Columnfa5e1et100DefectCh4Remoteread-onlycurrent5E1-ET100(T/S) Series card E1 channel 4 Defect Status: 0:No 1:Yes
1.3.6.1.4.1.4756.20.111.20.1.125Columnfa5e1et100DefectCh5Remoteread-onlycurrent5E1-ET100(T/S) Series card E1 channel 5 Defect Status: 0:No 1:Yes
1.3.6.1.4.1.4756.20.111.20.1.126Columnfa5e1et100FxSignalRemoteread-onlycurrent5E1-ET100(T/S) Series card Fiber signal detect(SD): 0:Fiber unplugged 1:Signal detected
1.3.6.1.4.1.4756.20.111.20.1.127Columnfa5e1et100PortResetRemoteread-writecurrent5E1-ET100(T/S) Series card Port Reset: 0:Action 1:Off
1.3.6.1.4.1.4756.20.111.20.1.128Columnfa5e1et100VLANModeRemoteread-writecurrent5E1-ET100(T/S) Series card VLAN mode: 0:MODE2 1:MODE1
1.3.6.1.4.1.4756.20.111.20.1.129Columnfa5e1et100ETagSelectEntryRemoteread-writecurrent5E1-ET100(T/S) Series card ETag select entry:
1.3.6.1.4.1.4756.20.111.20.1.130Columnfa5e1et100ETagMethodRemoteread-writecurrent5E1-ET100(T/S) Series card ETag Method: 0: Intouch 1: Add Tag 2: Remove Tag
1.3.6.1.4.1.4756.20.111.20.1.131Columnfa5e1et100VLANTableVID1Remoteread-writecurrent5E1-ET100(T/S) Series card VLAN Table: VLAN ID1
1.3.6.1.4.1.4756.20.111.20.1.132Columnfa5e1et100VLANTableVID2Remoteread-writecurrent5E1-ET100(T/S) Series card VLAN Table: VLAN ID2
1.3.6.1.4.1.4756.20.111.20.1.133Columnfa5e1et100VLANTableVID3Remoteread-writecurrent5E1-ET100(T/S) Series card VLAN Table: VLAN ID3
1.3.6.1.4.1.4756.20.111.20.1.134Columnfa5e1et100VLANTableVID4Remoteread-writecurrent5E1-ET100(T/S) Series card VLAN Table: VLAN ID4
1.3.6.1.4.1.4756.20.111.20.1.135Columnfa5e1et100VLANTableVID5Remoteread-writecurrent5E1-ET100(T/S) Series card VLAN Table: VLAN ID5
1.3.6.1.4.1.4756.20.111.20.1.136Columnfa5e1et100VLANTableVID6Remoteread-writecurrent5E1-ET100(T/S) Series card VLAN Table: VLAN ID6
1.3.6.1.4.1.4756.20.111.20.1.137Columnfa5e1et100VLANTableVID7Remoteread-writecurrent5E1-ET100(T/S) Series card VLAN Table: VLAN ID7
1.3.6.1.4.1.4756.20.111.20.1.138Columnfa5e1et100VLANTableVID8Remoteread-writecurrent5E1-ET100(T/S) Series card VLAN Table: VLAN ID8
1.3.6.1.4.1.4756.20.111.20.1.139Columnfa5e1et100VLANTableVID9Remoteread-writecurrent5E1-ET100(T/S) Series card VLAN Table: VLAN ID9
1.3.6.1.4.1.4756.20.111.20.1.140Columnfa5e1et100VLANTableVID10Remoteread-writecurrent5E1-ET100(T/S) Series card VLAN Table: VLAN ID10
1.3.6.1.4.1.4756.20.111.20.1.141Columnfa5e1et100VLANTableVID11Remoteread-writecurrent5E1-ET100(T/S) Series card VLAN Table: VLAN ID11
1.3.6.1.4.1.4756.20.111.20.1.142Columnfa5e1et100VLANTableVID12Remoteread-writecurrent5E1-ET100(T/S) Series card VLAN Table: VLAN ID12
1.3.6.1.4.1.4756.20.111.20.1.143Columnfa5e1et100VLANTableVID13Remoteread-writecurrent5E1-ET100(T/S) Series card VLAN Table: VLAN ID13
1.3.6.1.4.1.4756.20.111.20.1.144Columnfa5e1et100VLANTableVID14Remoteread-writecurrent5E1-ET100(T/S) Series card VLAN Table: VLAN ID14
1.3.6.1.4.1.4756.20.111.20.1.145Columnfa5e1et100VLANTableVID15Remoteread-writecurrent5E1-ET100(T/S) Series card VLAN Table: VLAN ID15
1.3.6.1.4.1.4756.20.111.20.1.146Columnfa5e1et100VLANTableVID16Remoteread-writecurrent5E1-ET100(T/S) Series card VLAN Table: VLAN ID16
1.3.6.1.4.1.4756.20.120Nodef155MSCards
1.3.6.1.4.1.4756.20.120.20Tablef155MSTablenot-accessiblecurrentA list of local FRM220-155MS card entries. The number of entries is f155MS-No.
1.3.6.1.4.1.4756.20.120.20.1Rowf155MSEntrynot-accessiblecurrentAn entry containing management information applicable to a particular local FRM220-155MS card.
1.3.6.1.4.1.4756.20.120.20.1.1Columnf155MSChassisIndexread-onlycurrentA unique value for each local card. It is the chassis location number.
1.3.6.1.4.1.4756.20.120.20.1.2Columnf155MSSlotIndexread-onlycurrentA unique value for each local card. It is the slot location number.
1.3.6.1.4.1.4756.20.120.20.1.3Columnf155MSCardHWVerread-onlycurrentLocal FRM220-f155MS card hardware version x.xxx
1.3.6.1.4.1.4756.20.120.20.1.4Columnf155MSCardFWVerread-onlycurrentLocal FRM220-f155MS card firmware version x.xxx
1.3.6.1.4.1.4756.20.120.20.1.5Columnf155MSCardCPLDVerread-onlycurrentLocal FRM220-f155MS card CPLD version x.xxx
1.3.6.1.4.1.4756.20.120.20.1.6Columnf155MSCardFPGAVerread-onlycurrentLocal FRM220-f155MS card FPGA version x.xxx
1.3.6.1.4.1.4756.20.120.20.1.7Columnf155MSPortActiveread-writecurrentLocal FRM220-f155MS card active: 0:Inactive 1:Active
1.3.6.1.4.1.4756.20.120.20.1.8Columnf155MSFxLLinkread-onlycurrentLocal FRM220-155MS card fiber of line side link status: 0:Down 1:Up
1.3.6.1.4.1.4756.20.120.20.1.9Columnf155MSFxCLinkread-onlycurrentLocal FRM220-155MS card fiber of client side link status: 0:Down 1:Up
1.3.6.1.4.1.4756.20.120.20.1.10Columnf155MSLnLBTestread-writecurrentForce local FRM220-155MS card to do fiber of line side LoopBack testing: 0:Off 1:Action
1.3.6.1.4.1.4756.20.120.20.1.11Columnf155MSCliLBTestread-writecurrentForce local FRM220-155MS card to do fiber of client side LoopBack testing: 0:Off 1:Action
1.3.6.1.4.1.4756.20.120.20.1.12Columnf155MSPortResetread-writecurrentForce remote FRM220-155MS card to reset mode: 0:Off 1:Action
1.3.6.1.4.1.4756.20.120.20.1.13Columnf155MSSetDefaultread-writecurrentForce remote FRM220-155MS card to default status: 0:Off 1:Action
1.3.6.1.4.1.4756.20.120.20.1.14Columnf155MSLfpModeread-writecurrentLocal FRM220-155MS card Link Fault Pass-through mode: 0:Disable 1:Enable
1.3.6.1.4.1.4756.20.120.20.1.15Columnf155MSAlsModeread-writecurrentLocal FRM220-155MS card Auto Laser Shutdown mode: 0:Disable 1:Enable
1.3.6.1.4.1.4756.20.120.20.1.16Columnf155MSFxLDDread-onlycurrentLocal FRM220-155MS card line side fiber Digital Diagnostic function: 0:No 1:Yes
1.3.6.1.4.1.4756.20.120.20.1.17Columnf155MSFxCDDread-onlycurrentLocal FRM220-155MS card client side fiber Digital Diagnostic function: 0:No 1:Yes
1.3.6.1.4.1.4756.20.120.20.1.18Columnf155MSLddVendorread-onlycurrentLocal FRM220-155MS card fiber D/D information: Vendor name
1.3.6.1.4.1.4756.20.120.20.1.19Columnf155MSLddPartNoread-onlycurrentLocal FRM220-155MS card fiber D/D information: Vendor part number
1.3.6.1.4.1.4756.20.120.20.1.20Columnf155MSLddFiberTyperead-onlycurrentLocal FRM220-155MS card fiber D/D information: Fiber Type
1.3.6.1.4.1.4756.20.120.20.1.21Columnf155MSLddWaveLenread-onlycurrentLocal FRM220-155MS card fiber D/D information: Wave length
1.3.6.1.4.1.4756.20.120.20.1.22Columnf155MSLddWaveLen2read-onlycurrentLocal FRM220-155MS card fiber D/D information: Wave length 2
1.3.6.1.4.1.4756.20.120.20.1.23Columnf155MSLddLinkLenread-onlycurrentLocal FRM220-155MS card fiber D/D information: Link length
1.3.6.1.4.1.4756.20.120.20.1.24Columnf155MSLddLenUnitread-onlycurrentLocal FRM220-155MS card fiber D/D information: Length Unit
1.3.6.1.4.1.4756.20.120.20.1.25Columnf155MSLddStatusread-onlycurrentLocal FRM220-155MS card fiber D/D information: Status Support
1.3.6.1.4.1.4756.20.120.20.1.26Columnf155MSLddRxSensread-onlycurrentLocal FRM220-155MS card fiber D/D information: Rx Sensitivity
1.3.6.1.4.1.4756.20.120.20.1.27Columnf155MSLddTxPWRread-onlycurrentLocal FRM220-155MS card fiber D/D information: Tx power
1.3.6.1.4.1.4756.20.120.20.1.28Columnf155MSLddRxPWRread-onlycurrentLocal FRM220-155MS card fiber D/D information: Rx power
1.3.6.1.4.1.4756.20.120.20.1.29Columnf155MSLddTempread-onlycurrentLocal FRM220-155MS card fiber D/D information: Temperature in degree C
1.3.6.1.4.1.4756.20.120.20.1.30Columnf155MSLddPWRMarginread-onlycurrentLocal FRM220-155MS card fiber D/D information: Power margin
1.3.6.1.4.1.4756.20.120.20.1.31Columnf155MSLddPWRLossread-onlycurrentLocal FRM220-155MS card fiber D/D information: Power loss
1.3.6.1.4.1.4756.20.120.20.1.32Columnf155MSCddVendorread-onlycurrentLocal FRM220-155MS card fiber D/D information: Vendor name
1.3.6.1.4.1.4756.20.120.20.1.33Columnf155MSCddPartNoread-onlycurrentLocal FRM220-155MS card fiber D/D information: Vendor part number
1.3.6.1.4.1.4756.20.120.20.1.34Columnf155MSCddFiberTyperead-onlycurrentLocal FRM220-155MS card fiber D/D information: Fiber Type
1.3.6.1.4.1.4756.20.120.20.1.35Columnf155MSCddWaveLenread-onlycurrentLocal FRM220-155MS card fiber D/D information: Wave length
1.3.6.1.4.1.4756.20.120.20.1.36Columnf155MSCddWaveLen2read-onlycurrentLocal FRM220-155MS card fiber D/D information: Wave length 2
1.3.6.1.4.1.4756.20.120.20.1.37Columnf155MSCddLinkLenread-onlycurrentLocal FRM220-155MS card fiber D/D information: Link length
1.3.6.1.4.1.4756.20.120.20.1.38Columnf155MSCddLenUnitread-onlycurrentLocal FRM220-155MS card fiber D/D information: Length Unit
1.3.6.1.4.1.4756.20.120.20.1.39Columnf155MSCddStatusread-onlycurrentLocal FRM220-155MS card fiber D/D information: Status Support
1.3.6.1.4.1.4756.20.120.20.1.40Columnf155MSCddRxSensread-onlycurrentLocal FRM220-155MS card fiber D/D information: Rx Sensitivity
1.3.6.1.4.1.4756.20.120.20.1.41Columnf155MSCddTxPWRread-onlycurrentLocal FRM220-155MS card fiber D/D information: Tx power
1.3.6.1.4.1.4756.20.120.20.1.42Columnf155MSCddRxPWRread-onlycurrentLocal FRM220-155MS card fiber D/D information: Rx power
1.3.6.1.4.1.4756.20.120.20.1.43Columnf155MSCddTempread-onlycurrentLocal FRM220-155MS card fiber D/D information: Temperature in degree C
1.3.6.1.4.1.4756.20.120.20.1.44Columnf155MSCddPWRMarginread-onlycurrentLocal FRM220-155MS card fiber D/D information: Power margin
1.3.6.1.4.1.4756.20.120.20.1.45Columnf155MSCddPWRLossread-onlycurrentLocal FRM220-155MS card fiber D/D information: Power loss
1.3.6.1.4.1.4756.20.130Nodef1000TSCards
1.3.6.1.4.1.4756.20.130.20Tablef1000TSTablenot-accessiblecurrentA list of local FRM220-1000TS card entries. The number of entries is f1000TS-No-L.
1.3.6.1.4.1.4756.20.130.20.1Rowf1000TSEntrynot-accessiblecurrentAn entry containing management information applicable to a particular local FRM220-1000TS card.
1.3.6.1.4.1.4756.20.130.20.1.1Columnf1000TSChassisIndexread-onlycurrentA unique value for each local card. It is the chassis location number.
1.3.6.1.4.1.4756.20.130.20.1.2Columnf1000TSSlotIndexread-onlycurrentA unique value for each local card. It is the slot location number.
1.3.6.1.4.1.4756.20.130.20.1.3Columnf1000TSCardHWVerread-onlycurrentLocal FRM220-1000TS card hardware version x.xxx
1.3.6.1.4.1.4756.20.130.20.1.4Columnf1000TSCardFWVerread-onlycurrentLocal FRM220-1000TS card firmware version x.xxx
1.3.6.1.4.1.4756.20.130.20.1.5Columnf1000TSCardCPLDVerread-onlycurrentLocal FRM220-1000TS card CPLD version x.xxx
1.3.6.1.4.1.4756.20.130.20.1.6Columnf1000TSCardFPGAVerread-onlycurrentLocal FRM220-1000TS card FPGA version x.xxx
1.3.6.1.4.1.4756.20.130.20.1.7Columnf1000TSModelread-onlycurrentLocal CardType: 0:FRM220-1000TS 1:FRM220-1000T
1.3.6.1.4.1.4756.20.130.20.1.8Columnf1000TSPortActiveread-writecurrentLocal FRM220-1000TS card active: 0:Inactive 1:Active
1.3.6.1.4.1.4756.20.130.20.1.9Columnf1000TSUtpLinkread-onlycurrentLocal FRM220-1000TS card UTP link status: 0:Down 1:Up
1.3.6.1.4.1.4756.20.130.20.1.10Columnf1000TSUtpRxActread-onlycurrentLocal FRM220-1000TS card UTP receive active status: 0:Off 1:On
1.3.6.1.4.1.4756.20.130.20.1.11Columnf1000TSUtpSpeedread-onlycurrentLocal FRM220-1000TS card UTP speed: 0:1000MHz
1.3.6.1.4.1.4756.20.130.20.1.12Columnf1000TSUtpDuplexread-writecurrentLocal FRM220-1000TS card UTP duplex: 0:Half duplex mode 1:Full duplex mode
1.3.6.1.4.1.4756.20.130.20.1.13Columnf1000TSFxLinkread-onlycurrentLocal FRM220-1000TS card fiber link status: 0:Down 1:Up
1.3.6.1.4.1.4756.20.130.20.1.14Columnf1000TSFxRxActread-onlycurrentLocal FRM220-1000TS card fiber receiver active status: 0:Off 1:On
1.3.6.1.4.1.4756.20.130.20.1.15Columnf1000TSFxNegoread-writecurrentLocal FRM220-1000TS card fiber negotiation: 0:Force 1:Auto
1.3.6.1.4.1.4756.20.130.20.1.16Columnf1000TSFxSpeedread-onlycurrentLocal FRM220-1000TS card fiber speed: 0:Speed 1000
1.3.6.1.4.1.4756.20.130.20.1.17Columnf1000TSFxRemoPWRAbread-onlycurrentLocal FRM220-1000TS card fiber Remote Power status: 0:Abnormal 1:OK
1.3.6.1.4.1.4756.20.130.20.1.18Columnf1000TSPortResetread-writecurrentForce local FRM220-1000TS card to reset mode: 0:Off 1:Action
1.3.6.1.4.1.4756.20.130.20.1.19Columnf1000TSLfpModeread-writecurrentLocal FRM220-1000TS card Link Fault Pass-through mode: 0:Disable 1:Enable
1.3.6.1.4.1.4756.20.130.20.1.20Columnf1000TSAlsModeread-writecurrentLocal FRM220-1000TS card Auto Laser Shutdown mode: 0:Disable 1:Enable
1.3.6.1.4.1.4756.20.130.20.1.21Columnf1000TSFxDDread-onlycurrentLocal FRM220-1000TS card fiber Digital Diagnostic function: 0:No 1:Yes
1.3.6.1.4.1.4756.20.130.20.1.22Columnf1000TSDDVendorread-onlycurrentLocal FRM220-1000TS card fiber D/D information: Vendor name
1.3.6.1.4.1.4756.20.130.20.1.23Columnf1000TSDDPartNoread-onlycurrentLocal FRM220-1000TS card fiber D/D information: Vendor part number
1.3.6.1.4.1.4756.20.130.20.1.24Columnf1000TSDDFiberTyperead-onlycurrentLocal FRM220-1000TS card fiber D/D information: Fiber Type
1.3.6.1.4.1.4756.20.130.20.1.25Columnf1000TSDDWaveLenread-onlycurrentLocal FRM220-1000TS card fiber D/D information: Wave length
1.3.6.1.4.1.4756.20.130.20.1.26Columnf1000TSDDWaveLen2read-onlycurrentLocal FRM220-1000TS card fiber D/D information: Wave length 2
1.3.6.1.4.1.4756.20.130.20.1.27Columnf1000TSDDLinkLenread-onlycurrentLocal FRM220-1000TS card fiber D/D information: Link length
1.3.6.1.4.1.4756.20.130.20.1.28Columnf1000TSDDLenUnitread-onlycurrentLocal FRM220-1000TS card fiber D/D information: Length Unit
1.3.6.1.4.1.4756.20.130.20.1.29Columnf1000TSDDStatusread-onlycurrentLocal FRM220-1000TS card fiber D/D information: Status Support
1.3.6.1.4.1.4756.20.130.20.1.30Columnf1000TSDDRxSensread-onlycurrentLocal FRM220-1000TS card fiber D/D information: Rx Sensitivity
1.3.6.1.4.1.4756.20.130.20.1.31Columnf1000TSDDTxPWRread-onlycurrentLocal FRM220-1000TS card fiber D/D information: Tx power
1.3.6.1.4.1.4756.20.130.20.1.32Columnf1000TSDDRxPWRread-onlycurrentLocal FRM220-1000TS card fiber D/D information: Rx power
1.3.6.1.4.1.4756.20.130.20.1.33Columnf1000TSDDTempread-onlycurrentLocal FRM220-1000TS card fiber D/D information: Temperature in degree C
1.3.6.1.4.1.4756.20.130.20.1.34Columnf1000TSDDPWRMarginread-onlycurrentLocal FRM220-1000TS card fiber D/D information: Power margin
1.3.6.1.4.1.4756.20.130.20.1.35Columnf1000TSDDPWRLossread-onlycurrentLocal FRM220-1000TS card fiber D/D information: Power loss
1.3.6.1.4.1.4756.20.140Nodef3R27GCards
1.3.6.1.4.1.4756.20.140.20Tablef3R27GTablenot-accessiblecurrentA list of local FRM220-3R27G card entries. The number of entries is f3R27G-No-L.
1.3.6.1.4.1.4756.20.140.20.1Rowf3R27GEntrynot-accessiblecurrentAn entry containing management information applicable to a particular local FRM220-3R27G card.
1.3.6.1.4.1.4756.20.140.20.1.1Columnf3R27GChassisIndexread-onlycurrentA unique value for each local card. It is the chassis location number.
1.3.6.1.4.1.4756.20.140.20.1.2Columnf3R27GSlotIndexread-onlycurrentA unique value for each local card. It is the slot location number.
1.3.6.1.4.1.4756.20.140.20.1.3Columnf3R27GCardHWVerread-onlycurrentLocal FRM220-3R27G card hardware version x.xxx
1.3.6.1.4.1.4756.20.140.20.1.4Columnf3R27GCardFWVerread-onlycurrentLocal FRM220-3R27G card firmware version x.xxx
1.3.6.1.4.1.4756.20.140.20.1.5Columnf3R27GCardCPLDVerread-onlycurrentLocal FRM220-3R27G card CPLD version x.xxx
1.3.6.1.4.1.4756.20.140.20.1.6Columnf3R27GCardFPGAVerread-onlycurrentLocal FRM220-3R27G card FPGA version x.xxx
1.3.6.1.4.1.4756.20.140.20.1.7Columnf3R27GModelread-onlycurrentLocal CardType: 0:FRM220-3R27G/2S 1:FRM220-3R27G/3S
1.3.6.1.4.1.4756.20.140.20.1.8Columnf3R27GDeviceActiveread-writecurrentLocal FRM220-3R27G card active: 0:Inactive 1:Active
1.3.6.1.4.1.4756.20.140.20.1.9Columnf3R27GFx1Linkread-onlycurrentLocal FRM220-3R27G card Fiber1 link status: 0:Down 1:Up
1.3.6.1.4.1.4756.20.140.20.1.10Columnf3R27GFx2Linkread-onlycurrentLocal FRM220-3R27G card Fiber2 link status: 0:Down 1:Up
1.3.6.1.4.1.4756.20.140.20.1.11Columnf3R27GFx3Linkread-onlycurrentLocal FRM220-3R27G card Fiber3 link status: 0:Down 1:Up
1.3.6.1.4.1.4756.20.140.20.1.12Columnf3R27GFx1TxFailread-onlycurrentLocal FRM220-3R27G card Fiber1 Transceiver Tx Detect: 0:Normal 1:Fail
1.3.6.1.4.1.4756.20.140.20.1.13Columnf3R27GFx2TxFailread-onlycurrentLocal FRM220-3R27G card Fiber2 Transceiver Tx Detect: 0:Normal 1:Fail
1.3.6.1.4.1.4756.20.140.20.1.14Columnf3R27GFx3TxFailread-onlycurrentLocal FRM220-3R27G card Fiber3 Transceiver Tx Detect: 0:Normal 1:Fail
1.3.6.1.4.1.4756.20.140.20.1.15Columnf3R27GFx1AlsModeread-writecurrentLocal FRM220-3R27G card Fiber1 Auto Laser Showdown: 0:Disable 1:Enable
1.3.6.1.4.1.4756.20.140.20.1.16Columnf3R27GFx2AlsModeread-writecurrentLocal FRM220-3R27G card Fiber2 Auto Laser Showdown: 0:Disable 1:Enable
1.3.6.1.4.1.4756.20.140.20.1.17Columnf3R27GFx3AlsModeread-writecurrentLocal FRM220-3R27G card Fiber3 Auto Laser Showdown: 0:Disable 1:Enable
1.3.6.1.4.1.4756.20.140.20.1.18Columnf3R27GPortResetread-writecurrentForce local FRM220-3R27G card to reset mode: 0:Off 1:Action
1.3.6.1.4.1.4756.20.140.20.1.19Columnf3R27GActivePathread-writecurrentLocal FRM220-3R27G card Active Protection Path: 0:Primary 1:Secondary
1.3.6.1.4.1.4756.20.140.20.1.20Columnf3R27GOpticFxProread-writecurrentLocal FRM220-3R27G card Optic Fiber Protection: 0:OFF 1:ON
1.3.6.1.4.1.4756.20.140.20.1.21Columnf3R27GLbsettingread-writecurrentLocal FRM220-3R27G card Loopback Test: 0:Disable 1:Line side enable 2:Client side enable 3:Line and Client enable
1.3.6.1.4.1.4756.20.140.20.1.22Columnf3R27GLossPropagationread-writecurrentLocal FRM220-3R27G card Link Fault Pass-through: 0:Disable 1:Enable
1.3.6.1.4.1.4756.20.140.20.1.23Columnf3R27GBaudRateread-writecurrentLocal FRM220-3R27G card Auto Select Client Master: 0:E3 1:DS3 2:OC-1 3:Fast Ethernet 4:OC-3/STM-1 5:OC-12/STM-4 6:Fiber Channel-1 7:OC-24 8:Giga ethernet 9:HD-…
1.3.6.1.4.1.4756.20.140.20.1.24Columnf3R27GFx1DDread-onlycurrentLocal FRM220-3R27G card fiber Digital Diagnostic function: 0:No 1:Yes
1.3.6.1.4.1.4756.20.140.20.1.25Columnf3R27GFx1DDVendorread-onlycurrentLocal FRM220-3R27G card fiber D/D information: Vendor name
1.3.6.1.4.1.4756.20.140.20.1.26Columnf3R27GFx1DDPartNoread-onlycurrentLocal FRM220-3R27G card fiber D/D information: Vendor part number
1.3.6.1.4.1.4756.20.140.20.1.27Columnf3R27GFx1DDFiberTyperead-onlycurrentLocal FRM220-3R27G card fiber D/D information: Fiber Type
1.3.6.1.4.1.4756.20.140.20.1.28Columnf3R27GFx1DDWaveLenread-onlycurrentLocal FRM220-3R27G card fiber D/D information: Wave length
1.3.6.1.4.1.4756.20.140.20.1.29Columnf3R27GFx1DDWaveLen2read-onlycurrentLocal FRM220-3R27G card fiber D/D information: Wave length 2
1.3.6.1.4.1.4756.20.140.20.1.30Columnf3R27GFx1DDLinkLenread-onlycurrentLocal FRM220-3R27G card fiber D/D information: Link length
1.3.6.1.4.1.4756.20.140.20.1.31Columnf3R27GFx1DDLenUnitread-onlycurrentLocal FRM220-3R27G card fiber D/D information: Length Unit
1.3.6.1.4.1.4756.20.140.20.1.32Columnf3R27GFx1DDStatusread-onlycurrentLocal FRM220-3R27G card fiber D/D information: Status Support
1.3.6.1.4.1.4756.20.140.20.1.33Columnf3R27GFx1DDRxSensread-onlycurrentLocal FRM220-3R27G card fiber D/D information: Rx Sensitivity
1.3.6.1.4.1.4756.20.140.20.1.34Columnf3R27GFx1DDTxPWRread-onlycurrentLocal FRM220-3R27G card fiber D/D information: Tx power
1.3.6.1.4.1.4756.20.140.20.1.35Columnf3R27GFx1DDRxPWRread-onlycurrentLocal FRM220-3R27G card fiber D/D information: Rx power
1.3.6.1.4.1.4756.20.140.20.1.36Columnf3R27GFx1DDTempread-onlycurrentLocal FRM220-3R27G card fiber D/D information: Temperature in degree C
1.3.6.1.4.1.4756.20.140.20.1.37Columnf3R27GFx1DDPWRMarginread-onlycurrentLocal FRM220-3R27G card fiber D/D information: Power margin
1.3.6.1.4.1.4756.20.140.20.1.38Columnf3R27GFx2DDread-onlycurrentLocal FRM220-3R27G card fiber2 Digital Diagnostic function: 0:No 1:Yes
1.3.6.1.4.1.4756.20.140.20.1.39Columnf3R27GFx2DDVendorread-onlycurrentLocal FRM220-3R27G card fiber2 D/D information: Vendor name
1.3.6.1.4.1.4756.20.140.20.1.40Columnf3R27GFx2DDPartNoread-onlycurrentLocal FRM220-3R27G card fiber2 D/D information: Vendor part number
1.3.6.1.4.1.4756.20.140.20.1.41Columnf3R27GFx2DDFiberTyperead-onlycurrentLocal FRM220-3R27G card fiber2 D/D information: Fiber Type
1.3.6.1.4.1.4756.20.140.20.1.42Columnf3R27GFx2DDWaveLenread-onlycurrentLocal FRM220-3R27G card fiber2 D/D information: Wave length
1.3.6.1.4.1.4756.20.140.20.1.43Columnf3R27GFx2DDWaveLen2read-onlycurrentLocal FRM220-3R27G card fiber2 D/D information: Wave length 2
1.3.6.1.4.1.4756.20.140.20.1.44Columnf3R27GFx2DDLinkLenread-onlycurrentLocal FRM220-3R27G card fiber2 D/D information: Link length
1.3.6.1.4.1.4756.20.140.20.1.45Columnf3R27GFx2DDLenUnitread-onlycurrentLocal FRM220-3R27G card fiber2 D/D information: Length Unit
1.3.6.1.4.1.4756.20.140.20.1.46Columnf3R27GFx2DDStatusread-onlycurrentLocal FRM220-3R27G card fiber2 D/D information: Status Support
1.3.6.1.4.1.4756.20.140.20.1.47Columnf3R27GFx2DDRxSensread-onlycurrentLocal FRM220-3R27G card fiber2 D/D information: Rx Sensitivity
1.3.6.1.4.1.4756.20.140.20.1.48Columnf3R27GFx2DDTxPWRread-onlycurrentLocal FRM220-3R27G card fiber2 D/D information: Tx power
1.3.6.1.4.1.4756.20.140.20.1.49Columnf3R27GFx2DDRxPWRread-onlycurrentLocal FRM220-3R27G card fiber2 D/D information: Rx power
1.3.6.1.4.1.4756.20.140.20.1.50Columnf3R27GFx2DDTempread-onlycurrentLocal FRM220-3R27G card fiber2 D/D information: Temperature in degree C
1.3.6.1.4.1.4756.20.140.20.1.51Columnf3R27GFx2DDPWRMarginread-onlycurrentLocal FRM220-3R27G card fiber2 D/D information: Power margin
1.3.6.1.4.1.4756.20.140.20.1.52Columnf3R27GFx3DDread-onlycurrentLocal FRM220-3R27G card fiber3 Digital Diagnostic function: 0:No 1:Yes
1.3.6.1.4.1.4756.20.140.20.1.53Columnf3R27GFx3DDVendorread-onlycurrentLocal FRM220-3R27G card fiber3 D/D information: Vendor name
1.3.6.1.4.1.4756.20.140.20.1.54Columnf3R27GFx3DDPartNoread-onlycurrentLocal FRM220-3R27G card fiber3 D/D information: Vendor part number
1.3.6.1.4.1.4756.20.140.20.1.55Columnf3R27GFx3DDFiberTyperead-onlycurrentLocal FRM220-3R27G card fiber3 D/D information: Fiber Type
1.3.6.1.4.1.4756.20.140.20.1.56Columnf3R27GFx3DDWaveLenread-onlycurrentLocal FRM220-3R27G card fiber3 D/D information: Wave length
1.3.6.1.4.1.4756.20.140.20.1.57Columnf3R27GFx3DDWaveLen2read-onlycurrentLocal FRM220-3R27G card fiber3 D/D information: Wave length 2
1.3.6.1.4.1.4756.20.140.20.1.58Columnf3R27GFx3DDLinkLenread-onlycurrentLocal FRM220-3R27G card fiber3 D/D information: Link length
1.3.6.1.4.1.4756.20.140.20.1.59Columnf3R27GFx3DDLenUnitread-onlycurrentLocal FRM220-3R27G card fiber3 D/D information: Length Unit
1.3.6.1.4.1.4756.20.140.20.1.60Columnf3R27GFx3DDStatusread-onlycurrentLocal FRM220-3R27G card fiber3 D/D information: Status Support
1.3.6.1.4.1.4756.20.140.20.1.61Columnf3R27GFx3DDRxSensread-onlycurrentLocal FRM220-3R27G card fiber3 D/D information: Rx Sensitivity
1.3.6.1.4.1.4756.20.140.20.1.62Columnf3R27GFx3DDTxPWRread-onlycurrentLocal FRM220-3R27G card fiber3 D/D information: Tx power
1.3.6.1.4.1.4756.20.140.20.1.63Columnf3R27GFx3DDRxPWRread-onlycurrentLocal FRM220-3R27G card fiber3 D/D information: Rx power
1.3.6.1.4.1.4756.20.140.20.1.64Columnf3R27GFx3DDTempread-onlycurrentLocal FRM220-3R27G card fiber3 D/D information: Temperature in degree C
1.3.6.1.4.1.4756.20.140.20.1.65Columnf3R27GFx3DDPWRMarginread-onlycurrentLocal FRM220-3R27G card fiber3 D/D information: Power margin
1.3.6.1.4.1.4756.20.140.20.1.66Columnf3R27GFx1LinkAlarmread-writecurrentLocal FRM220-3R27G card fiber 1 Link Alarm 0:Disable 1:Enable
1.3.6.1.4.1.4756.20.140.20.1.67Columnf3R27GFx2LinkAlarmread-writecurrentLocal FRM220-3R27G card fiber 2 Link Alarm 0:Disable 1:Enable
1.3.6.1.4.1.4756.20.140.20.1.68Columnf3R27GFx3LinkAlarmread-writecurrentLocal FRM220-3R27G card fiber 3 Link Alarm 0:Disable 1:Enable
1.3.6.1.4.1.4756.20.150Nodef1000EASLocalCards
1.3.6.1.4.1.4756.20.150.40Tablef1000EASLocalTablenot-accessiblecurrentA list of local frm220-1000EAS card entries. The number of entries is f1000EAS-NoLocal.
1.3.6.1.4.1.4756.20.150.40.1Rowf1000EASLocalEntrynot-accessiblecurrentAn entry containing management information applicable to a particular local FRM-1000EAS card.
1.3.6.1.4.1.4756.20.150.40.1.1Columnf1000EASChassisIndexLocalread-onlycurrentA unique value for each local card. It is the chassis location number.
1.3.6.1.4.1.4756.20.150.40.1.2Columnf1000EASSlotIndexLocalread-onlycurrentA unique value for each local card. It is the slot location number.
1.3.6.1.4.1.4756.20.150.40.1.3Columnf1000EASCardHWVerLocalread-onlycurrentLocal device card hardware version x.xxx
1.3.6.1.4.1.4756.20.150.40.1.4Columnf1000EASCardFWVerLocalread-onlycurrentLocal device card firmware version x.xxx
1.3.6.1.4.1.4756.20.150.40.1.5Columnf1000EASCardCPLDVerLocalread-onlycurrentLocal device card CPLD version x.xxx
1.3.6.1.4.1.4756.20.150.40.1.6Columnf1000EASCardFPGAVerLocalread-onlycurrentLocal device card FPGA version x.xxx
1.3.6.1.4.1.4756.20.150.40.1.7Columnf1000EASModelLocalread-onlycurrentLocal frm220 f1000EAS Serial Type
1.3.6.1.4.1.4756.20.150.40.1.8Columnf1000EASFx1LinkLocalread-onlycurrentLocal device card fiber port 1 link status: 0:Down 1:Up
1.3.6.1.4.1.4756.20.150.40.1.9Columnf1000EASFx1OAMLoopedLocalread-onlycurrentLocal device card fiber port 1 OAM looped: 0:Off 1:on
1.3.6.1.4.1.4756.20.150.40.1.10Columnf1000EASFx1LBTestLocalread-writecurrentForce remote device card to do fiber port 1 LoopBack testing: 0:Off 1:Action
1.3.6.1.4.1.4756.20.150.40.1.11Columnf1000EASFx1OAMRLBStatusLocalread-onlycurrentRemote device card fiber port 1 LoopBack testing status: 0:Off 1:Ok 2:Fail
1.3.6.1.4.1.4756.20.150.40.1.12Columnf1000EASFx1RemoPwrAbLocalread-onlycurrentLocal device card fiber port 1 Remote Power status: 0:Abnormal 1:OK 2:None
1.3.6.1.4.1.4756.20.150.40.1.13Columnf1000EASFx2LinkLocalread-onlycurrentLocal device card fiber port 2 link status: 0:Down 1:Up
1.3.6.1.4.1.4756.20.150.40.1.14Columnf1000EASFx2OAMLoopedLocalread-onlycurrentLocal device card fiber port 2 OAM looped: 0:Off 1:on
1.3.6.1.4.1.4756.20.150.40.1.15Columnf1000EASFx2LBTestLocalread-writecurrentForce remote device card to do fiber port 2 LoopBack testing: 0:Off 1:Action
1.3.6.1.4.1.4756.20.150.40.1.16Columnf1000EASFx2OAMRLBStatusLocalread-onlycurrentRemote device card fiber port 1 LoopBack testing status: 0:Off 1:Ok 2:Fail
1.3.6.1.4.1.4756.20.150.40.1.17Columnf1000EASFx2RemoPwrAbLocalread-onlycurrentLocal device card fiber port 2 Remote Power status: 0:Abnormal 1:OK 2:None
1.3.6.1.4.1.4756.20.150.40.1.18Columnf1000EASUtp1LinkLocalread-onlycurrentLocal device card UTP port 3 link status: 0:Down 1:Up
1.3.6.1.4.1.4756.20.150.40.1.19Columnf1000EASUtp1NegoLocalread-writecurrentLocal device card UTP port 3 negotiation status: 0:Manual 1:Auto
1.3.6.1.4.1.4756.20.150.40.1.20Columnf1000EASUtp1SpeedLocalread-writecurrentLocal device card UTP port 3 speed setting: 0:10 Base-T 1:100 Base-TX 2:1000 Base-TX
1.3.6.1.4.1.4756.20.150.40.1.21Columnf1000EASUtp1DuplexLocalread-writecurrentLocal device card UTP port 3 duplex setting: 0:Half duplex mode 1:Full duplex mode
1.3.6.1.4.1.4756.20.150.40.1.22Columnf1000EASUtp1SpeedStatusLocalread-onlycurrentLocal device card UTP port 3 speed status: 0:10 Base-T 1:100 Base-TX 2:1000 Base-TX
1.3.6.1.4.1.4756.20.150.40.1.23Columnf1000EASUtp1DuplexStatusLocalread-onlycurrentLocal device card UTP port 3 duplex status: 0:Half duplex mode 1:Full duplex mode
1.3.6.1.4.1.4756.20.150.40.1.24Columnf1000EASUtp2LinkLocalread-onlycurrentLocal device card UTP port 4 link status: 0:Down 1:Up
1.3.6.1.4.1.4756.20.150.40.1.25Columnf1000EASUtp2NegoLocalread-writecurrentLocal device card UTP port 4 negotiation status: 0:Manual 1:Auto
1.3.6.1.4.1.4756.20.150.40.1.26Columnf1000EASUtp2SpeedLocalread-writecurrentLocal device card UTP port 4 speed setting: 0:10 Base-T 1:100 Base-TX 2:1000 Base-TX
1.3.6.1.4.1.4756.20.150.40.1.27Columnf1000EASUtp2DuplexLocalread-writecurrentLocal device card UTP port 4 duplex setting: 0:Half duplex mode 1:Full duplex mode
1.3.6.1.4.1.4756.20.150.40.1.28Columnf1000EASUtp2SpeedStatusLocalread-onlycurrentLocal device card UTP port 4 speed status: 0:10 Base-T 1:100 Base-TX 2:1000 Base-TX
1.3.6.1.4.1.4756.20.150.40.1.29Columnf1000EASUtp2DuplexStatusLocalread-onlycurrentLocal device card UTP port 4 duplex status: 0:Half duplex mode 1:Full duplex mode
1.3.6.1.4.1.4756.20.150.40.1.30Columnf1000EASFx1IrlModeLocalread-writecurrentLocal device card port 1 Rate Limit mode: 0:unlimited 1:limited
1.3.6.1.4.1.4756.20.150.40.1.31Columnf1000EASFx1IrlIndexLocalread-writecurrentLocal device card port 1 Ingress Rate Limit index: Index Limit Rate Index Limit Rate 0 Disable 16 1M 1 250M 17 960K 2 140M 18 896K 3 95M 19 832K 4 57M 20 768K …
1.3.6.1.4.1.4756.20.150.40.1.32Columnf1000EASFx1ErlIndexLocalread-writecurrentLocal device card port 1 Egress Rate Limit index: Index Limit Rate Index Limit Rate 0 Disable 16 1M 1 250M 17 960K 2 140M 18 896K 3 95M 19 832K 4 57M 20 768K 5…
1.3.6.1.4.1.4756.20.150.40.1.33Columnf1000EASFx2IrlModeLocalread-writecurrentLocal device card port 2 Rate Limit mode: 0:unlimited 1:limited
1.3.6.1.4.1.4756.20.150.40.1.34Columnf1000EASFx2IrlIndexLocalread-writecurrentLocal device card port 2 Ingress Rate Limit index: Index Limit Rate Index Limit Rate 0 Disable 16 1M 1 250M 17 960K 2 140M 18 896K 3 95M 19 832K 4 57M 20 768K …
1.3.6.1.4.1.4756.20.150.40.1.35Columnf1000EASFx2ErlIndexLocalread-writecurrentLocal device card port 2 Egress Rate Limit index: Index Limit Rate Index Limit Rate 0 Disable 16 1M 1 250M 17 960K 2 140M 18 896K 3 95M 19 832K 4 57M 20 768K 5…
1.3.6.1.4.1.4756.20.150.40.1.36Columnf1000EASUtp1IrlModeLocalread-writecurrentLocal device card port 3 Rate Limit mode: 0:unlimited 1:limited
1.3.6.1.4.1.4756.20.150.40.1.37Columnf1000EASUtp1IrlIndexLocalread-writecurrentLocal device card port 3 Ingress Rate Limit index: Index Limit Rate Index Limit Rate 0 Disable 16 1M 1 250M 17 960K 2 140M 18 896K 3 95M 19 832K 4 57M 20 768K …
1.3.6.1.4.1.4756.20.150.40.1.38Columnf1000EASUtp1ErlIndexLocalread-writecurrentLocal device card port 3 Egress Rate Limit index: Index Limit Rate Index Limit Rate 0 Disable 16 1M 1 250M 17 960K 2 140M 18 896K 3 95M 19 832K 4 57M 20 768K 5…
1.3.6.1.4.1.4756.20.150.40.1.39Columnf1000EASUtp2IrlModeLocalread-writecurrentLocal device card port 4 Rate Limit mode: 0:unlimited 1:limited
1.3.6.1.4.1.4756.20.150.40.1.40Columnf1000EASUtp2IrlIndexLocalread-writecurrentLocal device card port 4 Ingress Rate Limit index: Index Limit Rate Index Limit Rate 0 Disable 16 1M 1 250M 17 960K 2 140M 18 896K 3 95M 19 832K 4 57M 20 768K …
1.3.6.1.4.1.4756.20.150.40.1.41Columnf1000EASUtp2ErlIndexLocalread-writecurrentLocal device card port 4 Egress Rate Limit index: Index Limit Rate Index Limit Rate 0 Disable 16 1M 1 250M 17 960K 2 140M 18 896K 3 95M 19 832K 4 57M 20 768K 5…
1.3.6.1.4.1.4756.20.150.40.1.42Columnf1000EASDeviceActiveLocalread-writecurrentLocal device card active mode: (It is read-only in local device.) 0:Disable 1:Enable
1.3.6.1.4.1.4756.20.150.40.1.43Columnf1000EASDeviceResetLocalread-writecurrentForce local device card to reset mode: 0:Off 1:Action
1.3.6.1.4.1.4756.20.150.40.1.44Columnf1000EASFx1ActiveLocalread-writecurrentLocal device fiber port 1 active mode: 0:Disable 1:Enable
1.3.6.1.4.1.4756.20.150.40.1.45Columnf1000EASFx2ActiveLocalread-writecurrentLocal device fiber port 2 active mode: 0:Disable 1:Enable
1.3.6.1.4.1.4756.20.150.40.1.46Columnf1000EASUtp1ActiveLocalread-writecurrentLocal device UTP port 3 active mode: 0:Disable 1:Enable
1.3.6.1.4.1.4756.20.150.40.1.47Columnf1000EASUtp2ActiveLocalread-writecurrentLocal device UTP port 4 active mode: 0:Disable 1:Enable
1.3.6.1.4.1.4756.20.150.40.1.48Columnf1000EASOamChAModeLocalread-writecurrentLocal device OAM Channel A mode: 0:Disable 1:passive 2:Active
1.3.6.1.4.1.4756.20.150.40.1.49Columnf1000EASOamChBModeLocalread-writecurrentLocal device OAM Channel B mode: 0:Disable 1:passive 2:Active
1.3.6.1.4.1.4756.20.150.40.1.50Columnf1000EASOamMaxPDUsLocalread-writecurrentLocal device OAM max OAMPDU size: 60-1518 Octets
1.3.6.1.4.1.4756.20.150.40.1.51Columnf1000EASFx1AlsLocalread-writecurrentLocal device card port 1 Auto Laser Shutdown mode: 0:Disable 1:Enable
1.3.6.1.4.1.4756.20.150.40.1.52Columnf1000EASFx2AlsLocalread-writecurrentLocal device card port 2 Auto Laser Shutdown mode: 0:Disable 1:Enable
1.3.6.1.4.1.4756.20.150.40.1.53Columnf1000EASPauseFrameLocalread-writecurrentLocal device card pause frame mode: 0:Disable 1:Enable
1.3.6.1.4.1.4756.20.150.40.1.54Columnf1000EASSendFHRtoALocalread-writecurrentLocal device card port 1 send Fiber Hardware Reset to remote: 0:No action 1:Action
1.3.6.1.4.1.4756.20.150.40.1.55Columnf1000EASSendFHRtoBLocalread-writecurrentLocal device card port 2 send Fiber Hardware Reset to remote: 0:No action 1:Action
1.3.6.1.4.1.4756.20.150.40.1.56Columnf1000EASFx1LLFDepLogiLocalread-writecurrentLocal device card port 1 Link Loss Forwarding depends boolean logic: 0:and 1:or
1.3.6.1.4.1.4756.20.150.40.1.57Columnf1000EASFx1LLFDepPort2Localread-writecurrentLocal device card port 1 Link Loss Forwarding depends on port 2 Fiber Rx link: 0:don't care 1:selected
1.3.6.1.4.1.4756.20.150.40.1.58Columnf1000EASFx1LLFDepPort3Localread-writecurrentLocal device card port 1 Link Loss Forwarding depends on port 3 Ethernet Rx link: 0:don't care 1:selected
1.3.6.1.4.1.4756.20.150.40.1.59Columnf1000EASFx1LLFDepPort4Localread-writecurrentLocal device card port 1 Link Loss Forwarding depends on port 4 Ethernet Rx link: 0:don't care 1:selected
1.3.6.1.4.1.4756.20.150.40.1.60Columnf1000EASFx2LLFDepLogiLocalread-writecurrentLocal device card port 2 Link Loss Forwarding depends boolean logic: 0:and 1:or
1.3.6.1.4.1.4756.20.150.40.1.61Columnf1000EASFx2LLFDepPort1Localread-writecurrentLocal device card port 2 Link Loss Forwarding depends on port 1 Fiber Rx link: 0:don't care 1:selected
1.3.6.1.4.1.4756.20.150.40.1.62Columnf1000EASFx2LLFDepPort3Localread-writecurrentLocal device card port 2 Link Loss Forwarding depends on port 3 Ethernet Rx link: 0:don't care 1:selected
1.3.6.1.4.1.4756.20.150.40.1.63Columnf1000EASFx2LLFDepPort4Localread-writecurrentLocal device card port 2 Link Loss Forwarding depends on port 4 Ethernet Rx link: 0:don't care 1:selected
1.3.6.1.4.1.4756.20.150.40.1.64Columnf1000EASUtp1LLFDepLogiLocalread-writecurrentLocal device card port 3 Link Loss Forwarding depends boolean logic: 0:and 1:or
1.3.6.1.4.1.4756.20.150.40.1.65Columnf1000EASUtp1LLFDepPort1Localread-writecurrentLocal device card port 3 Link Loss Forwarding depends on port 1 Fiber Rx link: 0:don't care 1:selected
1.3.6.1.4.1.4756.20.150.40.1.66Columnf1000EASUtp1LLFDepPort2Localread-writecurrentLocal device card port 3 Link Loss Forwarding depends on port 2 Fiber Rx link: 0:don't care 1:selected
1.3.6.1.4.1.4756.20.150.40.1.67Columnf1000EASUtp2LLFDepLogiLocalread-writecurrentLocal device card port 4 Link Loss Forwarding depends boolean logic: 0:and 1:or
1.3.6.1.4.1.4756.20.150.40.1.68Columnf1000EASUtp2LLFDepPort1Localread-writecurrentLocal device card port 4 Link Loss Forwarding depends on port 1 Fiber Rx link: 0:don't care 1:selected
1.3.6.1.4.1.4756.20.150.40.1.69Columnf1000EASUtp2LLFDepPort2Localread-writecurrentLocal device card port 4 Link Loss Forwarding depends on port 2 Fiber Rx link: 0:don't care 1:selected
1.3.6.1.4.1.4756.20.150.40.1.70Columnf1000EASAdvanceFunsLocalread-writecurrentLocal device card Switch functions mode: 0:Normal 1:Port 1&2 trunk bandwidth 2G 2:Port 1&2 Mirror 3:Port VLAN 1/3;2/4 4:Port 1&2 Redundancy 5:Static 802.1Q VLA…
1.3.6.1.4.1.4756.20.150.40.1.71Columnf1000EASFx1InfoROM1Localread-onlycurrentLocal device card port 1 INFORemoteOM information 1 valid: 0:Invalid 1:Valid
1.3.6.1.4.1.4756.20.150.40.1.72Columnf1000EASFx1InfoROM2Localread-onlycurrentLocal device card port 1 INFORemoteOM information 2 valid: 0:Invalid 1:Valid(replacing D/D function
1.3.6.1.4.1.4756.20.150.40.1.73Columnf1000EASFx2InfoROM1Localread-onlycurrentLocal device card port 2 INFORemoteOM information 1 valid: 0:Invalid 1:Valid
1.3.6.1.4.1.4756.20.150.40.1.74Columnf1000EASFx2InfoROM2Localread-onlycurrentLocal device card port 2 INFORemoteOM information 2 valid: 0:Invalid 1:Valid(replacing D/D function)
1.3.6.1.4.1.4756.20.150.40.1.75Columnf1000EASFx1InfoSN1Localread-onlycurrentLocal device card port 1 INFORemoteOM S/N 1
1.3.6.1.4.1.4756.20.150.40.1.76Columnf1000EASFx1InfoSN2Localread-onlycurrentLocal device card port 1 INFORemoteOM S/N 2
1.3.6.1.4.1.4756.20.150.40.1.77Columnf1000EASFx2InfoSN1Localread-onlycurrentLocal device card port 2 INFORemoteOM S/N 1
1.3.6.1.4.1.4756.20.150.40.1.78Columnf1000EASFx2InfoSN2Localread-onlycurrentLocal device card port 2 INFORemoteOM S/N 2
1.3.6.1.4.1.4756.20.150.40.1.79Columnf1000EASFx1DDLocalread-onlycurrentLocal device card fiber port 1 Digital Diagnostic function: 0:No 1:Yes
1.3.6.1.4.1.4756.20.150.40.1.80Columnf1000EASFx1DDVendorLocalread-onlycurrentLocal device card fiber port 1 D/D information: Vendor name
1.3.6.1.4.1.4756.20.150.40.1.81Columnf1000EASFx1DDPartNoLocalread-onlycurrentLocal device card fiber port 1 D/D information: Vendor part number
1.3.6.1.4.1.4756.20.150.40.1.82Columnf1000EASFx1DDFiberTypeLocalread-onlycurrentLocal device card fiber port 1 D/D information: Fiber Type
1.3.6.1.4.1.4756.20.150.40.1.83Columnf1000EASFx1DDWaveLenLocalread-onlycurrentLocal device card fiber port 1 D/D information: Wave length
1.3.6.1.4.1.4756.20.150.40.1.84Columnf1000EASFx1DDWaveLen2Localread-onlycurrentLocal device card fiber port 1 D/D information: Wave length 2
1.3.6.1.4.1.4756.20.150.40.1.85Columnf1000EASFx1DDLinkLenLocalread-onlycurrentLocal device card fiber port 1 D/D information: Link length
1.3.6.1.4.1.4756.20.150.40.1.86Columnf1000EASFx1DDLenUnitLocalread-onlycurrentLocal device card fiber port 1 D/D information: Length Unit
1.3.6.1.4.1.4756.20.150.40.1.87Columnf1000EASFx1DDStatusLocalread-onlycurrentLocal device card fiber port 1 D/D information: Status Support
1.3.6.1.4.1.4756.20.150.40.1.88Columnf1000EASFx1DDRxSensLocalread-onlycurrentLocal device card fiber port 1 D/D information: Rx Sensitivity
1.3.6.1.4.1.4756.20.150.40.1.89Columnf1000EASFx1DDTxPWRLocalread-onlycurrentLocal device card fiber port 1 D/D information: Tx power
1.3.6.1.4.1.4756.20.150.40.1.90Columnf1000EASFx1DDRxPWRLocalread-onlycurrentLocal device card fiber port 1 D/D information: Rx power
1.3.6.1.4.1.4756.20.150.40.1.91Columnf1000EASFx1DDTempLocalread-onlycurrentLocal device card fiber port 1 D/D information: Temperature in degree C
1.3.6.1.4.1.4756.20.150.40.1.92Columnf1000EASFx1DDPWRMarginLocalread-onlycurrentLocal device card fiber port 1 D/D information: Power margin
1.3.6.1.4.1.4756.20.150.40.1.93Columnf1000EASFx1DDPWRLossLocalread-onlycurrentLocal device card fiber port 1 D/D information: Power loss
1.3.6.1.4.1.4756.20.150.40.1.94Columnf1000EASFx2DDLocalread-onlycurrentLocal device card fiber port 2 Digital Diagnostic function: 0:No 1:Yes
1.3.6.1.4.1.4756.20.150.40.1.95Columnf1000EASFx2DDVendorLocalread-onlycurrentLocal device card fiber port 2 D/D information: Vendor name
1.3.6.1.4.1.4756.20.150.40.1.96Columnf1000EASFx2DDPartNoLocalread-onlycurrentLocal device card fiber port 2 D/D information: Vendor part number
1.3.6.1.4.1.4756.20.150.40.1.97Columnf1000EASFx2DDFiberTypeLocalread-onlycurrentLocal device card fiber port 2 D/D information: Fiber Type
1.3.6.1.4.1.4756.20.150.40.1.98Columnf1000EASFx2DDWaveLenLocalread-onlycurrentLocal device card fiber port 2 D/D information: Wave length
1.3.6.1.4.1.4756.20.150.40.1.99Columnf1000EASFx2DDWaveLen2Localread-onlycurrentLocal device card fiber port 2 D/D information: Wave length 2
1.3.6.1.4.1.4756.20.150.40.1.100Columnf1000EASFx2DDLinkLenLocalread-onlycurrentLocal device card fiber port 2 D/D information: Link length
1.3.6.1.4.1.4756.20.150.40.1.101Columnf1000EASFx2DDLenUnitLocalread-onlycurrentLocal device card fiber port 2 D/D information: Length Unit
1.3.6.1.4.1.4756.20.150.40.1.102Columnf1000EASFx2DDStatusLocalread-onlycurrentLocal device card fiber port 2 D/D information: Status Support
1.3.6.1.4.1.4756.20.150.40.1.103Columnf1000EASFx2DDRxSensLocalread-onlycurrentLocal device card fiber port 2 D/D information: Rx Sensitivity
1.3.6.1.4.1.4756.20.150.40.1.104Columnf1000EASFx2DDTxPWRLocalread-onlycurrentLocal device card fiber port 2 D/D information: Tx power
1.3.6.1.4.1.4756.20.150.40.1.105Columnf1000EASFx2DDRxPWRLocalread-onlycurrentLocal device card fiber port 2 D/D information: Rx power
1.3.6.1.4.1.4756.20.150.40.1.106Columnf1000EASFx2DDTempLocalread-onlycurrentLocal device card fiber port 2 D/D information: Temperature in degree C
1.3.6.1.4.1.4756.20.150.40.1.107Columnf1000EASFx2DDPWRMarginLocalread-onlycurrentLocal device card fiber port 2 D/D information: Power margin
1.3.6.1.4.1.4756.20.150.40.1.108Columnf1000EASFx2DDPWRLossLocalread-onlycurrentLocal device card fiber port 2 D/D information: Power loss
1.3.6.1.4.1.4756.20.150.40.1.109Columnf1000EASClrRMONCntsLocalread-writecurrentClear local device card RMON IN/OUT counters: 0:No action 1:Action
1.3.6.1.4.1.4756.20.150.40.1.110Columnf1000EASFx1RMONInLocalread-onlycurrentLocal device card port 1 RMON IN counter.
1.3.6.1.4.1.4756.20.150.40.1.111Columnf1000EASFx1RMONOutLocalread-onlycurrentLocal device card port 1 RMON OUT counter.
1.3.6.1.4.1.4756.20.150.40.1.112Columnf1000EASFx2RMONInLocalread-onlycurrentLocal device card port 2 RMON IN counter.
1.3.6.1.4.1.4756.20.150.40.1.113Columnf1000EASFx2RMONOutLocalread-onlycurrentLocal device card port 2 RMON OUT counter.
1.3.6.1.4.1.4756.20.150.40.1.114Columnf1000EASUtp1RMONInLocalread-onlycurrentLocal device card port 3 RMON IN counter.
1.3.6.1.4.1.4756.20.150.40.1.115Columnf1000EASUtp1RMONOutLocalread-onlycurrentLocal device card port 3 RMON OUT counter.
1.3.6.1.4.1.4756.20.150.40.1.116Columnf1000EASUtp2RMONInLocalread-onlycurrentLocal device card port 4 RMON IN counter.
1.3.6.1.4.1.4756.20.150.40.1.117Columnf1000EASUtp2RMONOutLocalread-onlycurrentLocal device card port 4 RMON OUT counter.
1.3.6.1.4.1.4756.20.150.40.1.118Columnf1000EASClrOAMCntsLocalread-writecurrentClear local device card OAM counters: 0:No action 1:Action
1.3.6.1.4.1.4756.20.150.40.1.119Columnf1000EASIpModeLocalread-writecurrentOn Rack Ip Mode: 0:Enable 1:Disable
1.3.6.1.4.1.4756.20.150.40.1.120Columnf1000EASOamChATxLocalread-onlycurrentLocal device OAM Channel A TX OAMPDU frame count
1.3.6.1.4.1.4756.20.150.40.1.121Columnf1000EASOamChARxLocalread-onlycurrentLocal device OAM Channel A RX OAMPDU frame count
1.3.6.1.4.1.4756.20.150.40.1.122Columnf1000EASOamInfoChATxLocalread-onlycurrentLocal device OAM Channel A TX Information OAMPDU frame count
1.3.6.1.4.1.4756.20.150.40.1.123Columnf1000EASOamInfoChARxLocalread-onlycurrentLocal device OAM Channel A RX Information OAMPDU frame count
1.3.6.1.4.1.4756.20.150.40.1.124Columnf1000EASOamEventChATxLocalread-onlycurrentLocal device OAM Channel A TX Event OAMPDU frame count
1.3.6.1.4.1.4756.20.150.40.1.125Columnf1000EASOamUniEvtChARxLocalread-onlycurrentLocal device OAM Channel A RX Unique Event OAMPDU frame count
1.3.6.1.4.1.4756.20.150.40.1.126Columnf1000EASOamDupEvtChARxLocalread-onlycurrentLocal device OAM Channel A RX Duplicate Event OAMPDU frame count
1.3.6.1.4.1.4756.20.150.40.1.127Columnf1000EASOamLbChATxLocalread-onlycurrentLocal device OAM Channel A TX Loopback Control OAMPDU frame count
1.3.6.1.4.1.4756.20.150.40.1.128Columnf1000EASOamLbChARxLocalread-onlycurrentLocal device OAM Channel A RX Loopback Control OAMPDU frame count
1.3.6.1.4.1.4756.20.150.40.1.129Columnf1000EASOamVarReqChATxLocalread-onlycurrentLocal device OAM Channel A TX Variable Request OAMPDU frame count
1.3.6.1.4.1.4756.20.150.40.1.130Columnf1000EASOamVarReqChARxLocalread-onlycurrentLocal device OAM Channel A RX Variable Request OAMPDU frame count
1.3.6.1.4.1.4756.20.150.40.1.131Columnf1000EASOamVarRspChATxLocalread-onlycurrentLocal device OAM Channel A TX Variable Response OAMPDU frame count
1.3.6.1.4.1.4756.20.150.40.1.132Columnf1000EASOamVarRspChARxLocalread-onlycurrentLocal device OAM Channel A RX Variable Response OAMPDU frame count
1.3.6.1.4.1.4756.20.150.40.1.133Columnf1000EASOamOuiChATxLocalread-onlycurrentLocal device OAM Channel A TX OUI OAMPDU frame count
1.3.6.1.4.1.4756.20.150.40.1.134Columnf1000EASOamOuiChARxLocalread-onlycurrentLocal device OAM Channel A RX OUI OAMPDU frame count
1.3.6.1.4.1.4756.20.150.40.1.135Columnf1000EASOamUnknowChARxLocalread-onlycurrentLocal device OAM Channel A RX Unsupported OAMPDU frame count
1.3.6.1.4.1.4756.20.150.40.1.136Columnf1000EASOamChBTxLocalread-onlycurrentLocal device OAM Channel B TX OAMPDU frame count
1.3.6.1.4.1.4756.20.150.40.1.137Columnf1000EASOamChBRxLocalread-onlycurrentLocal device OAM Channel B RX OAMPDU frame count
1.3.6.1.4.1.4756.20.150.40.1.138Columnf1000EASOamInfoChBTxLocalread-onlycurrentLocal device OAM Channel B TX Information OAMPDU frame count
1.3.6.1.4.1.4756.20.150.40.1.139Columnf1000EASOamInfoChBRxLocalread-onlycurrentLocal device OAM Channel B RX Information OAMPDU frame count
1.3.6.1.4.1.4756.20.150.40.1.140Columnf1000EASOamEventChBTxLocalread-onlycurrentLocal device OAM Channel B TX Event OAMPDU frame count
1.3.6.1.4.1.4756.20.150.40.1.141Columnf1000EASOamUniEvtChBRxLocalread-onlycurrentLocal device OAM Channel B RX Unique Event OAMPDU frame count
1.3.6.1.4.1.4756.20.150.40.1.142Columnf1000EASOamDupEvtChBRxLocalread-onlycurrentLocal device OAM Channel B RX Duplicate Event OAMPDU frame count
1.3.6.1.4.1.4756.20.150.40.1.143Columnf1000EASOamLbChBTxLocalread-onlycurrentLocal device OAM Channel B TX Loopback Control OAMPDU frame count
1.3.6.1.4.1.4756.20.150.40.1.144Columnf1000EASOamLbChBRxLocalread-onlycurrentLocal device OAM Channel B RX Loopback Control OAMPDU frame count
1.3.6.1.4.1.4756.20.150.40.1.145Columnf1000EASOamVarReqChBTxLocalread-onlycurrentLocal device OAM Channel B TX Variable Request OAMPDU frame count
1.3.6.1.4.1.4756.20.150.40.1.146Columnf1000EASOamVarReqChBRxLocalread-onlycurrentLocal device OAM Channel B RX Variable Request OAMPDU frame count
1.3.6.1.4.1.4756.20.150.40.1.147Columnf1000EASOamVarRspChBTxLocalread-onlycurrentLocal device OAM Channel B TX Variable Response OAMPDU frame count
1.3.6.1.4.1.4756.20.150.40.1.148Columnf1000EASOamVarRspChBRxLocalread-onlycurrentLocal device OAM Channel B RX Variable Response OAMPDU frame count
1.3.6.1.4.1.4756.20.150.40.1.149Columnf1000EASOamOuiChBTxLocalread-onlycurrentLocal device OAM Channel B TX OUI OAMPDU frame count
1.3.6.1.4.1.4756.20.150.40.1.150Columnf1000EASOamOuiChBRxLocalread-onlycurrentLocal device OAM Channel B RX OUI OAMPDU frame count
1.3.6.1.4.1.4756.20.150.40.1.151Columnf1000EASOamUnknowChBRxLocalread-onlycurrentLocal device OAM Channel B RX Unsupported OAMPDU frame count
1.3.6.1.4.1.4756.20.150.40.1.152Columnf1000EASFx1VLANLocalread-writecurrentLocal frm220 f1000EAS Fiber 1 VLAN group : 0:Group A 1:Group B
1.3.6.1.4.1.4756.20.150.40.1.153Columnf1000EASFx2VLANLocalread-writecurrentLocal frm220 f1000EAS Fiber 2 VLAN group : 0:Group A 1:Group B
1.3.6.1.4.1.4756.20.150.40.1.154Columnf1000EASUtp3VLANLocalread-writecurrentLocal frm220 f1000EAS UTP 3 VLAN group : 0:Group A 1:Group B
1.3.6.1.4.1.4756.20.150.40.1.155Columnf1000EASUtp4VLANLocalread-writecurrentLocal frm220 f1000EAS UTP 4 VLAN group : 0:Group A 1:Group B
1.3.6.1.4.1.4756.20.150.40.1.156Columnf1000EASManagementLocalread-writecurrentLocal frm220 f1000EAS management : 0:Group A 1:Group B 2:Group A+B
1.3.6.1.4.1.4756.20.150.40.1.157Columnf1000EASSetDefaultLocalread-writecurrentLocal frm220 f1000EAS set to default : 0:OFF 1:Actoin
1.3.6.1.4.1.4756.20.150.40.1.158Columnf1000EASPortVLANLocalread-writecurrentLocal frm220 Port VLAN : 0:Disable 1:Enable
1.3.6.1.4.1.4756.20.151Nodef1000EASRemoteACards
1.3.6.1.4.1.4756.20.151.40Tablef1000EASRemoteATablenot-accessiblecurrentA list of local frm220-1000EAS card entries. The number of entries is f1000EASRemoteA.
1.3.6.1.4.1.4756.20.151.40.1Rowf1000EASRemoteAEntrynot-accessiblecurrentAn entry containing management information applicable to a particular local frm220-1000EAS card.
1.3.6.1.4.1.4756.20.151.40.1.1Columnf1000EASChassisIndexRemoteAread-onlycurrentA unique value for each local card. It is the chassis location number.
1.3.6.1.4.1.4756.20.151.40.1.2Columnf1000EASSlotIndexRemoteAread-onlycurrentA unique value for each local card. It is the slot location number.
1.3.6.1.4.1.4756.20.151.40.1.3Columnf1000EASCardHWVerRemoteAread-onlycurrentRemote device card hardware version x.xxx
1.3.6.1.4.1.4756.20.151.40.1.4Columnf1000EASCardFWVerRemoteAread-onlycurrentRemote device card firmware version x.xxx
1.3.6.1.4.1.4756.20.151.40.1.5Columnf1000EASCardCPLDVerRemoteAread-onlycurrentRemote device card CPLD version x.xxx
1.3.6.1.4.1.4756.20.151.40.1.6Columnf1000EASCardFPGAVerRemoteAread-onlycurrentRemote device card FPGA version x.xxx
1.3.6.1.4.1.4756.20.151.40.1.7Columnf1000EASModelRemoteAread-onlycurrentRemote frm220 f1000EAS Serial Type
1.3.6.1.4.1.4756.20.151.40.1.8Columnf1000EASFx1LinkRemoteAread-onlycurrentRemote device card fiber port 1 link status: 0:Down 1:Up
1.3.6.1.4.1.4756.20.151.40.1.9Columnf1000EASFx1OAMLoopedRemoteAread-onlycurrentRemote device card fiber port 1 OAM looped: 0:Off 1:on
1.3.6.1.4.1.4756.20.151.40.1.10Columnf1000EASFx1LBTestRemoteAread-writecurrentForce remote device card to do fiber port 1 LoopBack testing: 0:Off 1:Action
1.3.6.1.4.1.4756.20.151.40.1.11Columnf1000EASFx1OAMRLBStatusRemoteAread-onlycurrentRemote device card fiber port 1 LoopBack testing status: 0:Off 1:Ok 2:Fail
1.3.6.1.4.1.4756.20.151.40.1.12Columnf1000EASFx1RemoPwrAbRemoteAread-onlycurrentRemote device card fiber port 1 Remote Power status: 0:Abnormal 1:OK 2:None
1.3.6.1.4.1.4756.20.151.40.1.13Columnf1000EASFx2LinkRemoteAread-onlycurrentRemote device card fiber port 2 link status: 0:Down 1:Up
1.3.6.1.4.1.4756.20.151.40.1.14Columnf1000EASFx2OAMLoopedRemoteAread-onlycurrentRemote device card fiber port 2 OAM looped: 0:Off 1:on
1.3.6.1.4.1.4756.20.151.40.1.15Columnf1000EASFx2LBTestRemoteAread-writecurrentForce remote device card to do fiber port 2 LoopBack testing: 0:Off 1:Action
1.3.6.1.4.1.4756.20.151.40.1.16Columnf1000EASFx2OAMRLBStatusRemoteAread-onlycurrentRemote device card fiber port 1 LoopBack testing status: 0:Off 1:Ok 2:Fail
1.3.6.1.4.1.4756.20.151.40.1.17Columnf1000EASFx2RemoPwrAbRemoteAread-onlycurrentRemote device card fiber port 2 Remote Power status: 0:Abnormal 1:OK 2:None
1.3.6.1.4.1.4756.20.151.40.1.18Columnf1000EASUtp1LinkRemoteAread-onlycurrentRemote device card UTP port 3 link status: 0:Down 1:Up
1.3.6.1.4.1.4756.20.151.40.1.19Columnf1000EASUtp1NegoRemoteAread-writecurrentRemote device card UTP port 3 negotiation status: 0:Manual 1:Auto
1.3.6.1.4.1.4756.20.151.40.1.20Columnf1000EASUtp1SpeedRemoteAread-writecurrentRemote device card UTP port 3 speed setting: 0:10 Base-T 1:100 Base-TX 2:1000 Base-TX
1.3.6.1.4.1.4756.20.151.40.1.21Columnf1000EASUtp1DuplexRemoteAread-writecurrentRemote device card UTP port 3 duplex setting: 0:Half duplex mode 1:Full duplex mode
1.3.6.1.4.1.4756.20.151.40.1.22Columnf1000EASUtp1SpeedStatusRemoteAread-onlycurrentRemote device card UTP port 3 speed status: 0:10 Base-T 1:100 Base-TX 2:1000 Base-TX
1.3.6.1.4.1.4756.20.151.40.1.23Columnf1000EASUtp1DuplexStatusRemoteAread-onlycurrentRemote device card UTP port 3 duplex status: 0:Half duplex mode 1:Full duplex mode
1.3.6.1.4.1.4756.20.151.40.1.24Columnf1000EASUtp2LinkRemoteAread-onlycurrentRemote device card UTP port 4 link status: 0:Down 1:Up
1.3.6.1.4.1.4756.20.151.40.1.25Columnf1000EASUtp2NegoRemoteAread-writecurrentRemote device card UTP port 4 negotiation status: 0:Manual 1:Auto
1.3.6.1.4.1.4756.20.151.40.1.26Columnf1000EASUtp2SpeedRemoteAread-writecurrentRemote device card UTP port 4 speed setting: 0:10 Base-T 1:100 Base-TX 2:1000 Base-TX
1.3.6.1.4.1.4756.20.151.40.1.27Columnf1000EASUtp2DuplexRemoteAread-writecurrentRemote device card UTP port 2 duplex setting: 0:Half duplex mode 1:Full duplex mode
1.3.6.1.4.1.4756.20.151.40.1.28Columnf1000EASUtp2SpeedStatusRemoteAread-onlycurrentRemote device card UTP port 4 speed status: 0:10 Base-T 1:100 Base-TX 2:1000 Base-TX
1.3.6.1.4.1.4756.20.151.40.1.29Columnf1000EASUtp2DuplexStatusRemoteAread-onlycurrentRemote device card UTP port 2 duplex status: 0:Half duplex mode 1:Full duplex mode
1.3.6.1.4.1.4756.20.151.40.1.30Columnf1000EASFx1IrlModeRemoteAread-writecurrentRemote device card port 1 Rate Limit mode: 0:unlimited 1:limited
1.3.6.1.4.1.4756.20.151.40.1.31Columnf1000EASFx1IrlIndexRemoteAread-writecurrentRemote device card port 1 Ingress Rate Limit index: Index Limit Rate Index Limit Rate 0 Disable 16 1M 1 250M 17 960K 2 140M 18 896K 3 95M 19 832K 4 57M 20 768K…
1.3.6.1.4.1.4756.20.151.40.1.32Columnf1000EASFx1ErlIndexRemoteAread-writecurrentRemote device card port 1 Egress Rate Limit index: Index Limit Rate Index Limit Rate 0 Disable 16 1M 1 250M 17 960K 2 140M 18 896K 3 95M 19 832K 4 57M 20 768K …
1.3.6.1.4.1.4756.20.151.40.1.33Columnf1000EASFx2IrlModeRemoteAread-writecurrentRemote device card port 2 Rate Limit mode: 0:unlimited 1:limited
1.3.6.1.4.1.4756.20.151.40.1.34Columnf1000EASFx2IrlIndexRemoteAread-writecurrentRemote device card port 2 Ingress Rate Limit index: Index Limit Rate Index Limit Rate 0 Disable 16 1M 1 250M 17 960K 2 140M 18 896K 3 95M 19 832K 4 57M 20 768K…
1.3.6.1.4.1.4756.20.151.40.1.35Columnf1000EASFx2ErlIndexRemoteAread-writecurrentRemote device card port 2 Egress Rate Limit index: Index Limit Rate Index Limit Rate 0 Disable 16 1M 1 250M 17 960K 2 140M 18 896K 3 95M 19 832K 4 57M 20 768K …
1.3.6.1.4.1.4756.20.151.40.1.36Columnf1000EASUtp1IrlModeRemoteAread-writecurrentRemote device card port 3 Rate Limit mode: 0:unlimited 1:limited
1.3.6.1.4.1.4756.20.151.40.1.37Columnf1000EASUtp1IrlIndexRemoteAread-writecurrentRemote device card port 3 Ingress Rate Limit index: Index Limit Rate Index Limit Rate 0 Disable 16 1M 1 250M 17 960K 2 140M 18 896K 3 95M 19 832K 4 57M 20 768K…
1.3.6.1.4.1.4756.20.151.40.1.38Columnf1000EASUtp1ErlIndexRemoteAread-writecurrentRemote device card port 3 Egress Rate Limit index: Index Limit Rate Index Limit Rate 0 Disable 16 1M 1 250M 17 960K 2 140M 18 896K 3 95M 19 832K 4 57M 20 768K …
1.3.6.1.4.1.4756.20.151.40.1.39Columnf1000EASUtp2IrlModeRemoteAread-writecurrentRemote device card port 4 Rate Limit mode: 0:unlimited 1:limited
1.3.6.1.4.1.4756.20.151.40.1.40Columnf1000EASUtp2IrlIndexRemoteAread-writecurrentRemote device card port 4 Ingress Rate Limit index: Index Limit Rate Index Limit Rate 0 Disable 16 1M 1 250M 17 960K 2 140M 18 896K 3 95M 19 832K 4 57M 20 768K…
1.3.6.1.4.1.4756.20.151.40.1.41Columnf1000EASUtp2ErlIndexRemoteAread-writecurrentRemote device card port 4 Egress Rate Limit index: Index Limit Rate Index Limit Rate 0 Disable 16 1M 1 250M 17 960K 2 140M 18 896K 3 95M 19 832K 4 57M 20 768K …
1.3.6.1.4.1.4756.20.151.40.1.42Columnf1000EASDeviceActiveRemoteAread-onlycurrentRemote device card active mode: (It is read-only in local device.) 0:Disable 1:Enable
1.3.6.1.4.1.4756.20.151.40.1.43Columnf1000EASDeviceResetRemoteAread-writecurrentForce local device card to reset mode: 0:Off 1:Action
1.3.6.1.4.1.4756.20.151.40.1.44Columnf1000EASFx1ActiveRemoteAread-onlycurrentRemote device fiber port 1 active mode: 0:Disable 1:Enable
1.3.6.1.4.1.4756.20.151.40.1.45Columnf1000EASFx2ActiveRemoteAread-onlycurrentRemote device fiber port 2 active mode: 0:Disable 1:Enable
1.3.6.1.4.1.4756.20.151.40.1.46Columnf1000EASUtp1ActiveRemoteAread-writecurrentRemote device UTP port 3 active mode: 0:Disable 1:Enable
1.3.6.1.4.1.4756.20.151.40.1.47Columnf1000EASUtp2ActiveRemoteAread-writecurrentRemote device UTP port 4 active mode: 0:Disable 1:Enable
1.3.6.1.4.1.4756.20.151.40.1.48Columnf1000EASOAMChAModeRemoteAread-writecurrentRemote device OAM Channel A mode: 0:Passive 1:Active
1.3.6.1.4.1.4756.20.151.40.1.49Columnf1000EASOAMChBModeRemoteAread-writecurrentRemote device OAM Channel B mode: 0:Passive 1:Active
1.3.6.1.4.1.4756.20.151.40.1.50Columnf1000EASOamMaxPDUsRemoteAread-writecurrentRemote device OAM max OAMPDU size: 60-1518 Octets
1.3.6.1.4.1.4756.20.151.40.1.51Columnf1000EASFx1AlsRemoteAread-writecurrentRemote device card port 1 Auto Laser Shutdown mode: 0:Disable 1:Enable
1.3.6.1.4.1.4756.20.151.40.1.52Columnf1000EASFx2AlsRemoteAread-writecurrentRemote device card port 2 Auto Laser Shutdown mode: 0:Disable 1:Enable
1.3.6.1.4.1.4756.20.151.40.1.53Columnf1000EASPauseFrameRemoteAread-writecurrentRemote device card pause frame mode: 0:Disable 1:Enable
1.3.6.1.4.1.4756.20.151.40.1.54Columnf1000EASFhrModeRemoteAread-writecurrentRemote device card accepts remote Fiber Hardware Reset mode: 0:Disable 1:Enable
1.3.6.1.4.1.4756.20.151.40.1.55Columnf1000EASFx1LLFDepLogiRemoteAread-writecurrentRemote device card port 1 Link Loss Forwarding depends boolean logic: 0:and 1:or
1.3.6.1.4.1.4756.20.151.40.1.56Columnf1000EASFx1LLFDepPort2RemoteAread-writecurrentRemote device card port 1 Link Loss Forwarding depends on port 2 Fiber Rx link: 0:don't care 1:selected
1.3.6.1.4.1.4756.20.151.40.1.57Columnf1000EASFx1LLFDepPort3RemoteAread-writecurrentRemote device card port 1 Link Loss Forwarding depends on port 3 Ethernet Rx link: 0:don't care 1:selected
1.3.6.1.4.1.4756.20.151.40.1.58Columnf1000EASFx1LLFDepPort4RemoteAread-writecurrentRemote device card port 1 Link Loss Forwarding depends on port 4 Ethernet Rx link: 0:don't care 1:selected
1.3.6.1.4.1.4756.20.151.40.1.59Columnf1000EASFx2LLFDepLogiRemoteAread-writecurrentRemote device card port 2 Link Loss Forwarding depends boolean logic: 0:and 1:or
1.3.6.1.4.1.4756.20.151.40.1.60Columnf1000EASFx2LLFDepPort1RemoteAread-writecurrentRemote device card port 2 Link Loss Forwarding depends on port 1 Fiber Rx link: 0:don't care 1:selected
1.3.6.1.4.1.4756.20.151.40.1.61Columnf1000EASFx2LLFDepPort3RemoteAread-writecurrentRemote device card port 2 Link Loss Forwarding depends on port 3 Ethernet Rx link: 0:don't care 1:selected
1.3.6.1.4.1.4756.20.151.40.1.62Columnf1000EASFx2LLFDepPort4RemoteAread-writecurrentRemote device card port 2 Link Loss Forwarding depends on port 4 Ethernet Rx link: 0:don't care 1:selected
1.3.6.1.4.1.4756.20.151.40.1.63Columnf1000EASUtp1LLFDepLogiRemoteAread-writecurrentRemote device card port 3 Link Loss Forwarding depends boolean logic: 0:and 1:or
1.3.6.1.4.1.4756.20.151.40.1.64Columnf1000EASUtp1LLFDepPort1RemoteAread-writecurrentRemote device card port 3 Link Loss Forwarding depends on port 1 Fiber Rx link: 0:don't care 1:selected
1.3.6.1.4.1.4756.20.151.40.1.65Columnf1000EASUtp1LLFDepPort2RemoteAread-writecurrentRemote device card port 3 Link Loss Forwarding depends on port 2 Fiber Rx link: 0:don't care 1:selected
1.3.6.1.4.1.4756.20.151.40.1.66Columnf1000EASUtp2LLFDepLogiRemoteAread-writecurrentRemote device card port 4 Link Loss Forwarding depends boolean logic: 0:and 1:or
1.3.6.1.4.1.4756.20.151.40.1.67Columnf1000EASUtp2LLFDepPort1RemoteAread-writecurrentRemote device card port 4 Link Loss Forwarding depends on port 1 Fiber Rx link: 0:don't care 1:selected
1.3.6.1.4.1.4756.20.151.40.1.68Columnf1000EASUtp2LLFDepPort2RemoteAread-writecurrentRemote device card port 4 Link Loss Forwarding depends on port 2 Fiber Rx link: 0:don't care 1:selected
1.3.6.1.4.1.4756.20.151.40.1.69Columnf1000EASAdvanceFunsRemoteAread-writecurrentRemote device card Switch functions mode: 0:Normal 1:Port 1&2 trunk bandwidth 2G 2:Port 1&2 Mirror 3:Port VLAN 1/3;2/4 4:Port 1&2 Redundancy 5:Static 802.1Q VL…
1.3.6.1.4.1.4756.20.151.40.1.70Columnf1000EASFx1InfoROM1RemoteAread-onlycurrentRemote device card port 1 INFORemoteOM information 1 valid: 0:Invalid 1:Valid
1.3.6.1.4.1.4756.20.151.40.1.71Columnf1000EASFx1InfoROM2RemoteAread-onlycurrentRemote device card port 1 INFORemoteOM information 2 valid: 0:Invalid 1:Valid(replacing D/D function
1.3.6.1.4.1.4756.20.151.40.1.72Columnf1000EASFx2InfoROM1RemoteAread-onlycurrentRemote device card port 2 INFORemoteOM information 1 valid: 0:Invalid 1:Valid
1.3.6.1.4.1.4756.20.151.40.1.73Columnf1000EASFx2InfoROM2RemoteAread-onlycurrentRemote device card port 2 INFORemoteOM information 2 valid: 0:Invalid 1:Valid(replacing D/D function)
1.3.6.1.4.1.4756.20.151.40.1.74Columnf1000EASFx1InfoSN1RemoteAread-onlycurrentRemote device card port 1 INFORemoteOM S/N 1
1.3.6.1.4.1.4756.20.151.40.1.75Columnf1000EASFx1InfoSN2RemoteAread-onlycurrentRemote device card port 1 INFORemoteOM S/N 2
1.3.6.1.4.1.4756.20.151.40.1.76Columnf1000EASFx2InfoSN1RemoteAread-onlycurrentRemote device card port 2 INFORemoteOM S/N 1
1.3.6.1.4.1.4756.20.151.40.1.77Columnf1000EASFx2InfoSN2RemoteAread-onlycurrentRemote device card port 2 INFORemoteOM S/N 2
1.3.6.1.4.1.4756.20.151.40.1.78Columnf1000EASFx1DDRemoteAread-onlycurrentRemote device card fiber port 1 Digital Diagnostic function: 0:No 1:Yes
1.3.6.1.4.1.4756.20.151.40.1.79Columnf1000EASFx1DDVendorRemoteAread-onlycurrentRemote device card fiber port 1 D/D information: Vendor name
1.3.6.1.4.1.4756.20.151.40.1.80Columnf1000EASFx1DDPartNoRemoteAread-onlycurrentRemote device card fiber port 1 D/D information: Vendor part number
1.3.6.1.4.1.4756.20.151.40.1.81Columnf1000EASFx1DDFiberTypeRemoteAread-onlycurrentRemote device card fiber port 1 D/D information: Fiber Type
1.3.6.1.4.1.4756.20.151.40.1.82Columnf1000EASFx1DDWaveLenRemoteAread-onlycurrentRemote device card fiber port 1 D/D information: Wave length
1.3.6.1.4.1.4756.20.151.40.1.83Columnf1000EASFx1DDWaveLen2RemoteAread-onlycurrentRemote device card fiber port 1 D/D information: Wave length 2
1.3.6.1.4.1.4756.20.151.40.1.84Columnf1000EASFx1DDLinkLenRemoteAread-onlycurrentRemote device card fiber port 1 D/D information: Link length
1.3.6.1.4.1.4756.20.151.40.1.85Columnf1000EASFx1DDLenUnitRemoteAread-onlycurrentRemote device card fiber port 1 D/D information: Length Unit
1.3.6.1.4.1.4756.20.151.40.1.86Columnf1000EASFx1DDStatusRemoteAread-onlycurrentRemote device card fiber port 1 D/D information: Status Support
1.3.6.1.4.1.4756.20.151.40.1.87Columnf1000EASFx1DDRxSensRemoteAread-onlycurrentRemote device card fiber port 1 D/D information: Rx Sensitivity
1.3.6.1.4.1.4756.20.151.40.1.88Columnf1000EASFx1DDTxPWRRemoteAread-onlycurrentRemote device card fiber port 1 D/D information: Tx power
1.3.6.1.4.1.4756.20.151.40.1.89Columnf1000EASFx1DDRxPWRRemoteAread-onlycurrentRemote device card fiber port 1 D/D information: Rx power
1.3.6.1.4.1.4756.20.151.40.1.90Columnf1000EASFx1DDTempRemoteAread-onlycurrentRemote device card fiber port 1 D/D information: Temperature in degree C
1.3.6.1.4.1.4756.20.151.40.1.91Columnf1000EASFx1DDPWRMarginRemoteAread-onlycurrentRemote device card fiber port 1 D/D information: Power margin
1.3.6.1.4.1.4756.20.151.40.1.92Columnf1000EASFx1DDPWRLossRemoteAread-onlycurrentRemote device card fiber port 1 D/D information: Power loss
1.3.6.1.4.1.4756.20.151.40.1.93Columnf1000EASFx2DDRemoteAread-onlycurrentRemote device card fiber port 2 Digital Diagnostic function: 0:No 1:Yes
1.3.6.1.4.1.4756.20.151.40.1.94Columnf1000EASFx2DDVendorRemoteAread-onlycurrentRemote device card fiber port 2 D/D information: Vendor name
1.3.6.1.4.1.4756.20.151.40.1.95Columnf1000EASFx2DDPartNoRemoteAread-onlycurrentRemote device card fiber port 2 D/D information: Vendor part number
1.3.6.1.4.1.4756.20.151.40.1.96Columnf1000EASFx2DDFiberTypeRemoteAread-onlycurrentRemote device card fiber port 2 D/D information: Fiber Type
1.3.6.1.4.1.4756.20.151.40.1.97Columnf1000EASFx2DDWaveLenRemoteAread-onlycurrentRemote device card fiber port 2 D/D information: Wave length
1.3.6.1.4.1.4756.20.151.40.1.98Columnf1000EASFx2DDWaveLen2RemoteAread-onlycurrentRemote device card fiber port 2 D/D information: Wave length 2
1.3.6.1.4.1.4756.20.151.40.1.99Columnf1000EASFx2DDLinkLenRemoteAread-onlycurrentRemote device card fiber port 2 D/D information: Link length
1.3.6.1.4.1.4756.20.151.40.1.100Columnf1000EASFx2DDLenUnitRemoteAread-onlycurrentRemote device card fiber port 2 D/D information: Length Unit
1.3.6.1.4.1.4756.20.151.40.1.101Columnf1000EASFx2DDStatusRemoteAread-onlycurrentRemote device card fiber port 2 D/D information: Status Support
1.3.6.1.4.1.4756.20.151.40.1.102Columnf1000EASFx2DDRxSensRemoteAread-onlycurrentRemote device card fiber port 2 D/D information: Rx Sensitivity
1.3.6.1.4.1.4756.20.151.40.1.103Columnf1000EASFx2DDTxPWRRemoteAread-onlycurrentRemote device card fiber port 2 D/D information: Tx power
1.3.6.1.4.1.4756.20.151.40.1.104Columnf1000EASFx2DDRxPWRRemoteAread-onlycurrentRemote device card fiber port 2 D/D information: Rx power
1.3.6.1.4.1.4756.20.151.40.1.105Columnf1000EASFx2DDTempRemoteAread-onlycurrentRemote device card fiber port 2 D/D information: Temperature in degree C
1.3.6.1.4.1.4756.20.151.40.1.106Columnf1000EASFx2DDPWRMarginRemoteAread-onlycurrentRemote device card fiber port 2 D/D information: Power margin
1.3.6.1.4.1.4756.20.151.40.1.107Columnf1000EASFx2DDPWRLossRemoteAread-onlycurrentRemote device card fiber port 2 D/D information: Power loss
1.3.6.1.4.1.4756.20.151.40.1.108Columnf1000EASClrRMONCntsRemoteAread-writecurrentClear local device card RMON IN/OUT counters: 0:No action 1:Action
1.3.6.1.4.1.4756.20.151.40.1.109Columnf1000EASFx1RMONInRemoteAread-onlycurrentRemote device card port 1 RMON IN counter.
1.3.6.1.4.1.4756.20.151.40.1.110Columnf1000EASFx1RMONOutRemoteAread-onlycurrentRemote device card port 1 RMON OUT counter.
1.3.6.1.4.1.4756.20.151.40.1.111Columnf1000EASFx2RMONInRemoteAread-onlycurrentRemote device card port 2 RMON IN counter.
1.3.6.1.4.1.4756.20.151.40.1.112Columnf1000EASFx2RMONOutRemoteAread-onlycurrentRemote device card port 2 RMON OUT counter.
1.3.6.1.4.1.4756.20.151.40.1.113Columnf1000EASUtp1RMONInRemoteAread-onlycurrentRemote device card port 3 RMON IN counter.
1.3.6.1.4.1.4756.20.151.40.1.114Columnf1000EASUtp1RMONOutRemoteAread-onlycurrentRemote device card port 3 RMON OUT counter.
1.3.6.1.4.1.4756.20.151.40.1.115Columnf1000EASUtp2RMONInRemoteAread-onlycurrentRemote device card port 4 RMON IN counter.
1.3.6.1.4.1.4756.20.151.40.1.116Columnf1000EASUtp2RMONOutRemoteAread-onlycurrentRemote device card port 4 RMON OUT counter.
1.3.6.1.4.1.4756.20.151.40.1.117Columnf1000EASClrOAMCntsRemoteAread-writecurrentClear local device card OAM counters: 0:No action 1:Action
1.3.6.1.4.1.4756.20.151.40.1.118Columnf1000EASIpModeRemoteAread-writecurrentOn Rack Ip Mode: 0:Enable 1:Disable
1.3.6.1.4.1.4756.20.151.40.1.119Columnf1000EASOamChATxRemoteAread-onlycurrentRemote device OAM Channel A TX OAMPDU frame count
1.3.6.1.4.1.4756.20.151.40.1.120Columnf1000EASOamChARxRemoteAread-onlycurrentRemote device OAM Channel A RX OAMPDU frame count
1.3.6.1.4.1.4756.20.151.40.1.121Columnf1000EASOamInfoChATxRemoteAread-onlycurrentRemote device OAM Channel A TX Information OAMPDU frame count
1.3.6.1.4.1.4756.20.151.40.1.122Columnf1000EASOamInfoChARxRemoteAread-onlycurrentRemote device OAM Channel A RX Information OAMPDU frame count
1.3.6.1.4.1.4756.20.151.40.1.123Columnf1000EASOamEventChATxRemoteAread-onlycurrentRemote device OAM Channel A TX Event OAMPDU frame count
1.3.6.1.4.1.4756.20.151.40.1.124Columnf1000EASOamUniEvtChARxRemoteAread-onlycurrentRemote device OAM Channel A RX Unique Event OAMPDU frame count
1.3.6.1.4.1.4756.20.151.40.1.125Columnf1000EASOamDupEvtChARxRemoteAread-onlycurrentRemote device OAM Channel A RX Duplicate Event OAMPDU frame count
1.3.6.1.4.1.4756.20.151.40.1.126Columnf1000EASOamLbChATxRemoteAread-onlycurrentRemote device OAM Channel A TX Loopback Control OAMPDU frame count
1.3.6.1.4.1.4756.20.151.40.1.127Columnf1000EASOamLbChARxRemoteAread-onlycurrentRemote device OAM Channel A RX Loopback Control OAMPDU frame count
1.3.6.1.4.1.4756.20.151.40.1.128Columnf1000EASOamVarReqChATxRemoteAread-onlycurrentRemote device OAM Channel A TX Variable Request OAMPDU frame count
1.3.6.1.4.1.4756.20.151.40.1.129Columnf1000EASOamVarReqChARxRemoteAread-onlycurrentRemote device OAM Channel A RX Variable Request OAMPDU frame count
1.3.6.1.4.1.4756.20.151.40.1.130Columnf1000EASOamVarRspChATxRemoteAread-onlycurrentRemote device OAM Channel A TX Variable Response OAMPDU frame count
1.3.6.1.4.1.4756.20.151.40.1.131Columnf1000EASOamVarRspChARxRemoteAread-onlycurrentRemote device OAM Channel A RX Variable Response OAMPDU frame count
1.3.6.1.4.1.4756.20.151.40.1.132Columnf1000EASOamOuiChATxRemoteAread-onlycurrentRemote device OAM Channel A TX OUI OAMPDU frame count
1.3.6.1.4.1.4756.20.151.40.1.133Columnf1000EASOamOuiChARxRemoteAread-onlycurrentRemote device OAM Channel A RX OUI OAMPDU frame count
1.3.6.1.4.1.4756.20.151.40.1.134Columnf1000EASOamUnknowChARxRemoteAread-onlycurrentRemote device OAM Channel A RX Unsupported OAMPDU frame count
1.3.6.1.4.1.4756.20.151.40.1.135Columnf1000EASOamChBTxRemoteAread-onlycurrentRemote device OAM Channel B TX OAMPDU frame count
1.3.6.1.4.1.4756.20.151.40.1.136Columnf1000EASOamChBRxRemoteAread-onlycurrentRemote device OAM Channel B RX OAMPDU frame count
1.3.6.1.4.1.4756.20.151.40.1.137Columnf1000EASOamInfoChBTxRemoteAread-onlycurrentRemote device OAM Channel B TX Information OAMPDU frame count
1.3.6.1.4.1.4756.20.151.40.1.138Columnf1000EASOamInfoChBRxRemoteAread-onlycurrentRemote device OAM Channel B RX Information OAMPDU frame count
1.3.6.1.4.1.4756.20.151.40.1.139Columnf1000EASOamEventChBTxRemoteAread-onlycurrentRemote device OAM Channel B TX Event OAMPDU frame count
1.3.6.1.4.1.4756.20.151.40.1.140Columnf1000EASOamUniEvtChBRxRemoteAread-onlycurrentRemote device OAM Channel B RX Unique Event OAMPDU frame count
1.3.6.1.4.1.4756.20.151.40.1.141Columnf1000EASOamDupEvtChBRxRemoteAread-onlycurrentRemote device OAM Channel B RX Duplicate Event OAMPDU frame count
1.3.6.1.4.1.4756.20.151.40.1.142Columnf1000EASOamLbChBTxRemoteAread-onlycurrentRemote device OAM Channel B TX Loopback Control OAMPDU frame count
1.3.6.1.4.1.4756.20.151.40.1.143Columnf1000EASOamLbChBRxRemoteAread-onlycurrentRemote device OAM Channel B RX Loopback Control OAMPDU frame count
1.3.6.1.4.1.4756.20.151.40.1.144Columnf1000EASOamVarReqChBTxRemoteAread-onlycurrentRemote device OAM Channel B TX Variable Request OAMPDU frame count
1.3.6.1.4.1.4756.20.151.40.1.145Columnf1000EASOamVarReqChBRxRemoteAread-onlycurrentRemote device OAM Channel B RX Variable Request OAMPDU frame count
1.3.6.1.4.1.4756.20.151.40.1.146Columnf1000EASOamVarRspChBTxRemoteAread-onlycurrentRemote device OAM Channel B TX Variable Response OAMPDU frame count
1.3.6.1.4.1.4756.20.151.40.1.147Columnf1000EASOamVarRspChBRxRemoteAread-onlycurrentRemote device OAM Channel B RX Variable Response OAMPDU frame count
1.3.6.1.4.1.4756.20.151.40.1.148Columnf1000EASOamOuiChBTxRemoteAread-onlycurrentRemote device OAM Channel B TX OUI OAMPDU frame count
1.3.6.1.4.1.4756.20.151.40.1.149Columnf1000EASOamOuiChBRxRemoteAread-onlycurrentRemote device OAM Channel B RX OUI OAMPDU frame count
1.3.6.1.4.1.4756.20.151.40.1.150Columnf1000EASOamUnknowChBRxRemoteAread-onlycurrentRemote device OAM Channel B RX Unsupported OAMPDU frame count
1.3.6.1.4.1.4756.20.151.40.1.151Columnf1000EASFx1VLANRemoteAread-writecurrentRemoteA frm220 f1000EAS Fiber 1 VLAN group : 0:Group A 1:Group B
1.3.6.1.4.1.4756.20.151.40.1.152Columnf1000EASFx2VLANRemoteAread-writecurrentRemoteA frm220 f1000EAS Fiber 2 VLAN group : 0:Group A 1:Group B
1.3.6.1.4.1.4756.20.151.40.1.153Columnf1000EASUtp3VLANRemoteAread-writecurrentRemoteA frm220 f1000EAS UTP 3 VLAN group : 0:Group A 1:Group B
1.3.6.1.4.1.4756.20.151.40.1.154Columnf1000EASUtp4VLANRemoteAread-writecurrentRemoteA frm220 f1000EAS UTP 4 VLAN group : 0:Group A 1:Group B
1.3.6.1.4.1.4756.20.151.40.1.155Columnf1000EASManagementRemoteAread-writecurrentRemoteA frm220 f1000EAS management : 0:Group A 1:Group B 2:Group A+B
1.3.6.1.4.1.4756.20.151.40.1.156Columnf1000EASSetDefaultRemoteAread-writecurrentRemoteA frm220 f1000EAS set to default : 0:OFF 1:Actoin
1.3.6.1.4.1.4756.20.151.40.1.157Columnf1000EASPortVLANRemoteAread-writecurrentRemoteA frm220 Port VLAN : 0:Disable 1:Enable
1.3.6.1.4.1.4756.20.152Nodef1000EASRemoteBCards
1.3.6.1.4.1.4756.20.152.40Tablef1000EASRemoteBTablenot-accessiblecurrentA list of local frm220-1000EAS card entries. The number of entries is f1000EAS-NoRemoteB.
1.3.6.1.4.1.4756.20.152.40.1Rowf1000EASRemoteBEntrynot-accessiblecurrentAn entry containing management information applicable to a particular local frm220-1000EAS card.
1.3.6.1.4.1.4756.20.152.40.1.1Columnf1000EASChassisIndexRemoteBread-onlycurrentA unique value for each local card. It is the chassis location number.
1.3.6.1.4.1.4756.20.152.40.1.2Columnf1000EASSlotIndexRemoteBread-onlycurrentA unique value for each local card. It is the slot location number.
1.3.6.1.4.1.4756.20.152.40.1.3Columnf1000EASCardHWVerRemoteBread-onlycurrentRemote device card hardware version x.xxx
1.3.6.1.4.1.4756.20.152.40.1.4Columnf1000EASCardFWVerRemoteBread-onlycurrentRemote device card firmware version x.xxx
1.3.6.1.4.1.4756.20.152.40.1.5Columnf1000EASCardCPLDVerRemoteBread-onlycurrentRemote device card CPLD version x.xxx
1.3.6.1.4.1.4756.20.152.40.1.6Columnf1000EASCardFPGAVerRemoteBread-onlycurrentRemote device card FPGA version x.xxx
1.3.6.1.4.1.4756.20.152.40.1.7Columnf1000EASModelRemoteBread-onlycurrentRemote frm220 f1000EAS Serial Type
1.3.6.1.4.1.4756.20.152.40.1.8Columnf1000EASFx1LinkRemoteBread-onlycurrentRemote device card fiber port 1 link status: 0:Down 1:Up
1.3.6.1.4.1.4756.20.152.40.1.9Columnf1000EASFx1OAMLoopedRemoteBread-onlycurrentRemote device card fiber port 1 OAM looped: 0:Off 1:on
1.3.6.1.4.1.4756.20.152.40.1.10Columnf1000EASFx1LBTestRemoteBread-writecurrentForce remote device card to do fiber port 1 LoopBack testing: 0:Off 1:Action
1.3.6.1.4.1.4756.20.152.40.1.11Columnf1000EASFx1OAMRLBStatusRemoteBread-onlycurrentRemote device card fiber port 1 LoopBack testing status: 0:Off 1:Ok 2:Fail
1.3.6.1.4.1.4756.20.152.40.1.12Columnf1000EASFx1RemoPwrAbRemoteBread-onlycurrentRemote device card fiber port 1 Remote Power status: 0:Abnormal 1:OK 2:None
1.3.6.1.4.1.4756.20.152.40.1.13Columnf1000EASFx2LinkRemoteBread-onlycurrentRemote device card fiber port 2 link status: 0:Down 1:Up
1.3.6.1.4.1.4756.20.152.40.1.14Columnf1000EASFx2OAMLoopedRemoteBread-onlycurrentRemote device card fiber port 2 OAM looped: 0:Off 1:on
1.3.6.1.4.1.4756.20.152.40.1.15Columnf1000EASFx2LBTestRemoteBread-writecurrentForce remote device card to do fiber port 2 LoopBack testing: 0:Off 1:Action
1.3.6.1.4.1.4756.20.152.40.1.16Columnf1000EASFx2OAMRLBStatusRemoteBread-onlycurrentRemote device card fiber port 2 LoopBack testing status: 0:Off 1:Ok 2:Fail
1.3.6.1.4.1.4756.20.152.40.1.17Columnf1000EASFx2RemoPwrAbRemoteBread-onlycurrentRemote device card fiber port 2 Remote Power status: 0:Abnormal 1:OK 2:None
1.3.6.1.4.1.4756.20.152.40.1.18Columnf1000EASUtp1LinkRemoteBread-onlycurrentRemote device card UTP port 3 link status: 0:Down 1:Up
1.3.6.1.4.1.4756.20.152.40.1.19Columnf1000EASUtp1NegoRemoteBread-writecurrentRemote device card UTP port 3 negotiation status: 0:Manual 1:Auto
1.3.6.1.4.1.4756.20.152.40.1.20Columnf1000EASUtp1SpeedRemoteBread-writecurrentRemote device card UTP port 3 speed setting: 0:10 Base-T 1:100 Base-TX 2:1000 Base-TX
1.3.6.1.4.1.4756.20.152.40.1.21Columnf1000EASUtp1DuplexRemoteBread-writecurrentRemote device card UTP port 3 duplex setting: 0:Half duplex mode 1:Full duplex mode
1.3.6.1.4.1.4756.20.152.40.1.22Columnf1000EASUtp1SpeedStatusRemoteBread-onlycurrentRemote device card UTP port 3 speed status: 0:10 Base-T 1:100 Base-TX 2:1000 Base-TX
1.3.6.1.4.1.4756.20.152.40.1.23Columnf1000EASUtp1DuplexStatusRemoteBread-onlycurrentRemote device card UTP port 3 duplex status: 0:Half duplex mode 1:Full duplex mode
1.3.6.1.4.1.4756.20.152.40.1.24Columnf1000EASUtp2LinkRemoteBread-onlycurrentRemote device card UTP port 4 link status: 0:Down 1:Up
1.3.6.1.4.1.4756.20.152.40.1.25Columnf1000EASUtp2NegoRemoteBread-writecurrentRemote device card UTP port 4 negotiation status: 0:Manual 1:Auto
1.3.6.1.4.1.4756.20.152.40.1.26Columnf1000EASUtp2SpeedRemoteBread-writecurrentRemote device card UTP port 4 speed setting: 0:10 Base-T 1:100 Base-TX 2:1000 Base-TX
1.3.6.1.4.1.4756.20.152.40.1.27Columnf1000EASUtp2DuplexRemoteBread-writecurrentRemote device card UTP port 4 duplex setting: 0:Half duplex mode 1:Full duplex mode
1.3.6.1.4.1.4756.20.152.40.1.28Columnf1000EASUtp2SpeedStatusRemoteBread-onlycurrentRemote device card UTP port 4 speed status: 0:10 Base-T 1:100 Base-TX 2:1000 Base-TX
1.3.6.1.4.1.4756.20.152.40.1.29Columnf1000EASUtp2DuplexStatusRemoteBread-onlycurrentRemote device card UTP port 4 duplex status: 0:Half duplex mode 1:Full duplex mode
1.3.6.1.4.1.4756.20.152.40.1.30Columnf1000EASFx1IrlModeRemoteBread-writecurrentRemote device card port 1 Rate Limit mode: 0:unlimited 1:limited
1.3.6.1.4.1.4756.20.152.40.1.31Columnf1000EASFx1IrlIndexRemoteBread-writecurrentRemote device card port 1 Ingress Rate Limit index: Index Limit Rate Index Limit Rate 0 Disable 16 1M 1 250M 17 960K 2 140M 18 896K 3 95M 19 832K 4 57M 20 768K…
1.3.6.1.4.1.4756.20.152.40.1.32Columnf1000EASFx1ErlIndexRemoteBread-writecurrentRemote device card port 1 Egress Rate Limit index: Index Limit Rate Index Limit Rate 0 Disable 16 1M 1 250M 17 960K 2 140M 18 896K 3 95M 19 832K 4 57M 20 768K …
1.3.6.1.4.1.4756.20.152.40.1.33Columnf1000EASFx2IrlModeRemoteBread-writecurrentRemote device card port 2 Rate Limit mode: 0:unlimited 1:limited
1.3.6.1.4.1.4756.20.152.40.1.34Columnf1000EASFx2IrlIndexRemoteBread-writecurrentRemote device card port 2 Ingress Rate Limit index: Index Limit Rate Index Limit Rate 0 Disable 16 1M 1 250M 17 960K 2 140M 18 896K 3 95M 19 832K 4 57M 20 768K…
1.3.6.1.4.1.4756.20.152.40.1.35Columnf1000EASFx2ErlIndexRemoteBread-writecurrentRemote device card port 2 Egress Rate Limit index: Index Limit Rate Index Limit Rate 0 Disable 16 1M 1 250M 17 960K 2 140M 18 896K 3 95M 19 832K 4 57M 20 768K …
1.3.6.1.4.1.4756.20.152.40.1.36Columnf1000EASUtp1IrlModeRemoteBread-writecurrentRemote device card port 3 Rate Limit mode: 0:unlimited 1:limited
1.3.6.1.4.1.4756.20.152.40.1.37Columnf1000EASUtp1IrlIndexRemoteBread-writecurrentRemote device card port 3 Ingress Rate Limit index: Index Limit Rate Index Limit Rate 0 Disable 16 1M 1 250M 17 960K 2 140M 18 896K 3 95M 19 832K 4 57M 20 768K…
1.3.6.1.4.1.4756.20.152.40.1.38Columnf1000EASUtp1ErlIndexRemoteBread-writecurrentRemote device card port 3 Egress Rate Limit index: Index Limit Rate Index Limit Rate 0 Disable 16 1M 1 250M 17 960K 2 140M 18 896K 3 95M 19 832K 4 57M 20 768K …
1.3.6.1.4.1.4756.20.152.40.1.39Columnf1000EASUtp2IrlModeRemoteBread-writecurrentRemote device card port 4 Rate Limit mode: 0:unlimited 1:limited
1.3.6.1.4.1.4756.20.152.40.1.40Columnf1000EASUtp2IrlIndexRemoteBread-writecurrentRemote device card port 4 Ingress Rate Limit index: Index Limit Rate Index Limit Rate 0 Disable 16 1M 1 250M 17 960K 2 140M 18 896K 3 95M 19 832K 4 57M 20 768K…
1.3.6.1.4.1.4756.20.152.40.1.41Columnf1000EASUtp2ErlIndexRemoteBread-writecurrentRemote device card port 4 Egress Rate Limit index: Index Limit Rate Index Limit Rate 0 Disable 16 1M 1 250M 17 960K 2 140M 18 896K 3 95M 19 832K 4 57M 20 768K …
1.3.6.1.4.1.4756.20.152.40.1.42Columnf1000EASDeviceActiveRemoteBread-onlycurrentRemote device card active mode: (It is read-only in local device.) 0:Disable 1:Enable
1.3.6.1.4.1.4756.20.152.40.1.43Columnf1000EASDeviceResetRemoteBread-writecurrentForce local device card to reset mode: 0:Off 1:Action
1.3.6.1.4.1.4756.20.152.40.1.44Columnf1000EASFx1ActiveRemoteBread-onlycurrentRemote device fiber port 1 active mode: 0:Disable 1:Enable
1.3.6.1.4.1.4756.20.152.40.1.45Columnf1000EASFx2ActiveRemoteBread-onlycurrentRemote device fiber port 2 active mode: 0:Disable 1:Enable
1.3.6.1.4.1.4756.20.152.40.1.46Columnf1000EASUtp1ActiveRemoteBread-writecurrentRemote device UTP port 3 active mode: 0:Disable 1:Enable
1.3.6.1.4.1.4756.20.152.40.1.47Columnf1000EASUtp2ActiveRemoteBread-writecurrentRemote device UTP port 4 active mode: 0:Disable 1:Enable
1.3.6.1.4.1.4756.20.152.40.1.48Columnf1000EASOAMChAModeRemoteBread-writecurrentRemote device OAM Channel A mode: 0:Passive 1:Active
1.3.6.1.4.1.4756.20.152.40.1.49Columnf1000EASOAMChBModeRemoteBread-writecurrentRemote device OAM Channel B mode: 0:Passive 1:Active
1.3.6.1.4.1.4756.20.152.40.1.50Columnf1000EASOamMaxPDUsRemoteBread-writecurrentRemote device OAM max OAMPDU size: 60-1518 Octets
1.3.6.1.4.1.4756.20.152.40.1.51Columnf1000EASFx1AlsRemoteBread-writecurrentRemote device card port 1 Auto Laser Shutdown mode: 0:Disable 1:Enable
1.3.6.1.4.1.4756.20.152.40.1.52Columnf1000EASFx2AlsRemoteBread-writecurrentRemote device card port 2 Auto Laser Shutdown mode: 0:Disable 1:Enable
1.3.6.1.4.1.4756.20.152.40.1.53Columnf1000EASPauseFrameRemoteBread-writecurrentRemote device card pause frame mode: 0:Disable 1:Enable
1.3.6.1.4.1.4756.20.152.40.1.54Columnf1000EASFhrModeRemoteBread-writecurrentRemote device card accepts remote Fiber Hardware Reset mode: 0:Disable 1:Enable
1.3.6.1.4.1.4756.20.152.40.1.55Columnf1000EASFx1LLFDepLogiRemoteBread-writecurrentRemote device card port 1 Link Loss Forwarding depends boolean logic: 0:and 1:or
1.3.6.1.4.1.4756.20.152.40.1.56Columnf1000EASFx1LLFDepPort2RemoteBread-writecurrentRemote device card port 1 Link Loss Forwarding depends on port 2 Fiber Rx link: 0:don't care 1:selected
1.3.6.1.4.1.4756.20.152.40.1.57Columnf1000EASFx1LLFDepPort3RemoteBread-writecurrentRemote device card port 1 Link Loss Forwarding depends on port 3 Ethernet Rx link: 0:don't care 1:selected
1.3.6.1.4.1.4756.20.152.40.1.58Columnf1000EASFx1LLFDepPort4RemoteBread-writecurrentRemote device card port 1 Link Loss Forwarding depends on port 4 Ethernet Rx link: 0:don't care 1:selected
1.3.6.1.4.1.4756.20.152.40.1.59Columnf1000EASFx2LLFDepLogiRemoteBread-writecurrentRemote device card port 2 Link Loss Forwarding depends boolean logic: 0:and 1:or
1.3.6.1.4.1.4756.20.152.40.1.60Columnf1000EASFx2LLFDepPort1RemoteBread-writecurrentRemote device card port 2 Link Loss Forwarding depends on port 1 Fiber Rx link: 0:don't care 1:selected
1.3.6.1.4.1.4756.20.152.40.1.61Columnf1000EASFx2LLFDepPort3RemoteBread-writecurrentRemote device card port 2 Link Loss Forwarding depends on port 3 Ethernet Rx link: 0:don't care 1:selected
1.3.6.1.4.1.4756.20.152.40.1.62Columnf1000EASFx2LLFDepPort4RemoteBread-writecurrentRemote device card port 2 Link Loss Forwarding depends on port 4 Ethernet Rx link: 0:don't care 1:selected
1.3.6.1.4.1.4756.20.152.40.1.63Columnf1000EASUtp1LLFDepLogiRemoteBread-writecurrentRemote device card port 3 Link Loss Forwarding depends boolean logic: 0:and 1:or
1.3.6.1.4.1.4756.20.152.40.1.64Columnf1000EASUtp1LLFDepPort1RemoteBread-writecurrentRemote device card port 3 Link Loss Forwarding depends on port 1 Fiber Rx link: 0:don't care 1:selected
1.3.6.1.4.1.4756.20.152.40.1.65Columnf1000EASUtp1LLFDepPort2RemoteBread-writecurrentRemote device card port 3 Link Loss Forwarding depends on port 2 Fiber Rx link: 0:don't care 1:selected
1.3.6.1.4.1.4756.20.152.40.1.66Columnf1000EASUtp2LLFDepLogiRemoteBread-writecurrentRemote device card port 4 Link Loss Forwarding depends boolean logic: 0:and 1:or
1.3.6.1.4.1.4756.20.152.40.1.67Columnf1000EASUtp2LLFDepPort1RemoteBread-writecurrentRemote device card port 4 Link Loss Forwarding depends on port 1 Fiber Rx link: 0:don't care 1:selected
1.3.6.1.4.1.4756.20.152.40.1.68Columnf1000EASUtp2LLFDepPort2RemoteBread-writecurrentRemote device card port 4 Link Loss Forwarding depends on port 2 Fiber Rx link: 0:don't care 1:selected
1.3.6.1.4.1.4756.20.152.40.1.69Columnf1000EASAdvanceFunsRemoteBread-writecurrentRemote device card Switch functions mode: 0:Normal 1:Port 1&2 trunk bandwidth 2G 2:Port 1&2 Mirror 3:Port VLAN 1/3;2/4 4:Port 1&2 Redundancy 5:Static 802.1Q VL…
1.3.6.1.4.1.4756.20.152.40.1.70Columnf1000EASFx1InfoROM1RemoteBread-onlycurrentRemote device card port 1 INFORemoteOM information 1 valid: 0:Invalid 1:Valid
1.3.6.1.4.1.4756.20.152.40.1.71Columnf1000EASFx1InfoROM2RemoteBread-onlycurrentRemote device card port 1 INFORemoteOM information 2 valid: 0:Invalid 1:Valid(replacing D/D function
1.3.6.1.4.1.4756.20.152.40.1.72Columnf1000EASFx2InfoROM1RemoteBread-onlycurrentRemote device card port 2 INFORemoteOM information 1 valid: 0:Invalid 1:Valid
1.3.6.1.4.1.4756.20.152.40.1.73Columnf1000EASFx2InfoROM2RemoteBread-onlycurrentRemote device card port 2 INFORemoteOM information 2 valid: 0:Invalid 1:Valid(replacing D/D function)
1.3.6.1.4.1.4756.20.152.40.1.74Columnf1000EASFx1InfoSN1RemoteBread-onlycurrentRemote device card port 1 INFORemoteOM S/N 1
1.3.6.1.4.1.4756.20.152.40.1.75Columnf1000EASFx1InfoSN2RemoteBread-onlycurrentRemote device card port 1 INFORemoteOM S/N 2
1.3.6.1.4.1.4756.20.152.40.1.76Columnf1000EASFx2InfoSN1RemoteBread-onlycurrentRemote device card port 2 INFORemoteOM S/N 1
1.3.6.1.4.1.4756.20.152.40.1.77Columnf1000EASFx2InfoSN2RemoteBread-onlycurrentRemote device card port 2 INFORemoteOM S/N 2
1.3.6.1.4.1.4756.20.152.40.1.78Columnf1000EASFx1DDRemoteBread-onlycurrentRemote device card fiber port 1 Digital Diagnostic function: 0:No 1:Yes
1.3.6.1.4.1.4756.20.152.40.1.79Columnf1000EASFx1DDVendorRemoteBread-onlycurrentRemote device card fiber port 1 D/D information: Vendor name
1.3.6.1.4.1.4756.20.152.40.1.80Columnf1000EASFx1DDPartNoRemoteBread-onlycurrentRemote device card fiber port 1 D/D information: Vendor part number
1.3.6.1.4.1.4756.20.152.40.1.81Columnf1000EASFx1DDFiberTypeRemoteBread-onlycurrentRemote device card fiber port 1 D/D information: Fiber Type
1.3.6.1.4.1.4756.20.152.40.1.82Columnf1000EASFx1DDWaveLenRemoteBread-onlycurrentRemote device card fiber port 1 D/D information: Wave length
1.3.6.1.4.1.4756.20.152.40.1.83Columnf1000EASFx1DDWaveLen2RemoteBread-onlycurrentRemote device card fiber port 1 D/D information: Wave length 2
1.3.6.1.4.1.4756.20.152.40.1.84Columnf1000EASFx1DDLinkLenRemoteBread-onlycurrentRemote device card fiber port 1 D/D information: Link length
1.3.6.1.4.1.4756.20.152.40.1.85Columnf1000EASFx1DDLenUnitRemoteBread-onlycurrentRemote device card fiber port 1 D/D information: Length Unit
1.3.6.1.4.1.4756.20.152.40.1.86Columnf1000EASFx1DDStatusRemoteBread-onlycurrentRemote device card fiber port 1 D/D information: Status Support
1.3.6.1.4.1.4756.20.152.40.1.87Columnf1000EASFx1DDRxSensRemoteBread-onlycurrentRemote device card fiber port 1 D/D information: Rx Sensitivity
1.3.6.1.4.1.4756.20.152.40.1.88Columnf1000EASFx1DDTxPWRRemoteBread-onlycurrentRemote device card fiber port 1 D/D information: Tx power
1.3.6.1.4.1.4756.20.152.40.1.89Columnf1000EASFx1DDRxPWRRemoteBread-onlycurrentRemote device card fiber port 1 D/D information: Rx power
1.3.6.1.4.1.4756.20.152.40.1.90Columnf1000EASFx1DDTempRemoteBread-onlycurrentRemote device card fiber port 1 D/D information: Temperature in degree C
1.3.6.1.4.1.4756.20.152.40.1.91Columnf1000EASFx1DDPWRMarginRemoteBread-onlycurrentRemote device card fiber port 1 D/D information: Power margin
1.3.6.1.4.1.4756.20.152.40.1.92Columnf1000EASFx1DDPWRLossRemoteBread-onlycurrentRemote device card fiber port 1 D/D information: Power loss
1.3.6.1.4.1.4756.20.152.40.1.93Columnf1000EASFx2DDRemoteBread-onlycurrentRemote device card fiber port 2 Digital Diagnostic function: 0:No 1:Yes
1.3.6.1.4.1.4756.20.152.40.1.94Columnf1000EASFx2DDVendorRemoteBread-onlycurrentRemote device card fiber port 2 D/D information: Vendor name
1.3.6.1.4.1.4756.20.152.40.1.95Columnf1000EASFx2DDPartNoRemoteBread-onlycurrentRemote device card fiber port 2 D/D information: Vendor part number
1.3.6.1.4.1.4756.20.152.40.1.96Columnf1000EASFx2DDFiberTypeRemoteBread-onlycurrentRemote device card fiber port 2 D/D information: Fiber Type
1.3.6.1.4.1.4756.20.152.40.1.97Columnf1000EASFx2DDWaveLenRemoteBread-onlycurrentRemote device card fiber port 2 D/D information: Wave length
1.3.6.1.4.1.4756.20.152.40.1.98Columnf1000EASFx2DDWaveLen2RemoteBread-onlycurrentRemote device card fiber port 2 D/D information: Wave length 2
1.3.6.1.4.1.4756.20.152.40.1.99Columnf1000EASFx2DDLinkLenRemoteBread-onlycurrentRemote device card fiber port 2 D/D information: Link length
1.3.6.1.4.1.4756.20.152.40.1.100Columnf1000EASFx2DDLenUnitRemoteBread-onlycurrentRemote device card fiber port 2 D/D information: Length Unit
1.3.6.1.4.1.4756.20.152.40.1.101Columnf1000EASFx2DDStatusRemoteBread-onlycurrentRemote device card fiber port 2 D/D information: Status Support
1.3.6.1.4.1.4756.20.152.40.1.102Columnf1000EASFx2DDRxSensRemoteBread-onlycurrentRemote device card fiber port 2 D/D information: Rx Sensitivity
1.3.6.1.4.1.4756.20.152.40.1.103Columnf1000EASFx2DDTxPWRRemoteBread-onlycurrentRemote device card fiber port 2 D/D information: Tx power
1.3.6.1.4.1.4756.20.152.40.1.104Columnf1000EASFx2DDRxPWRRemoteBread-onlycurrentRemote device card fiber port 2 D/D information: Rx power
1.3.6.1.4.1.4756.20.152.40.1.105Columnf1000EASFx2DDTempRemoteBread-onlycurrentRemote device card fiber port 2 D/D information: Temperature in degree C
1.3.6.1.4.1.4756.20.152.40.1.106Columnf1000EASFx2DDPWRMarginRemoteBread-onlycurrentRemote device card fiber port 2 D/D information: Power margin
1.3.6.1.4.1.4756.20.152.40.1.107Columnf1000EASFx2DDPWRLossRemoteBread-onlycurrentRemote device card fiber port 2 D/D information: Power loss
1.3.6.1.4.1.4756.20.152.40.1.108Columnf1000EASClrRMONCntsRemoteBread-writecurrentClear local device card RMON IN/OUT counters: 0:No action 1:Action
1.3.6.1.4.1.4756.20.152.40.1.109Columnf1000EASFx1RMONInRemoteBread-onlycurrentRemote device card port 1 RMON IN counter.
1.3.6.1.4.1.4756.20.152.40.1.110Columnf1000EASFx1RMONOutRemoteBread-onlycurrentRemote device card port 1 RMON OUT counter.
1.3.6.1.4.1.4756.20.152.40.1.111Columnf1000EASFx2RMONInRemoteBread-onlycurrentRemote device card port 2 RMON IN counter.
1.3.6.1.4.1.4756.20.152.40.1.112Columnf1000EASFx2RMONOutRemoteBread-onlycurrentRemote device card port 2 RMON OUT counter.
1.3.6.1.4.1.4756.20.152.40.1.113Columnf1000EASUtp1RMONInRemoteBread-onlycurrentRemote device card port 3 RMON IN counter.
1.3.6.1.4.1.4756.20.152.40.1.114Columnf1000EASUtp1RMONOutRemoteBread-onlycurrentRemote device card port 3 RMON OUT counter.
1.3.6.1.4.1.4756.20.152.40.1.115Columnf1000EASUtp2RMONInRemoteBread-onlycurrentRemote device card port 4 RMON IN counter.
1.3.6.1.4.1.4756.20.152.40.1.116Columnf1000EASUtp2RMONOutRemoteBread-onlycurrentRemote device card port 4 RMON OUT counter.
1.3.6.1.4.1.4756.20.152.40.1.117Columnf1000EASClrOAMCntsRemoteBread-writecurrentClear local device card OAM counters: 0:No action 1:Action
1.3.6.1.4.1.4756.20.152.40.1.118Columnf1000EASIpModeRemoteBread-writecurrentOn Rack Ip Mode: 0:Enable 1:Disable
1.3.6.1.4.1.4756.20.152.40.1.119Columnf1000EASOamChATxRemoteBread-onlycurrentRemote device OAM Channel A TX OAMPDU frame count
1.3.6.1.4.1.4756.20.152.40.1.120Columnf1000EASOamChARxRemoteBread-onlycurrentRemote device OAM Channel A RX OAMPDU frame count
1.3.6.1.4.1.4756.20.152.40.1.121Columnf1000EASOamInfoChATxRemoteBread-onlycurrentRemote device OAM Channel A TX Information OAMPDU frame count
1.3.6.1.4.1.4756.20.152.40.1.122Columnf1000EASOamInfoChARxRemoteBread-onlycurrentRemote device OAM Channel A RX Information OAMPDU frame count
1.3.6.1.4.1.4756.20.152.40.1.123Columnf1000EASOamEventChATxRemoteBread-onlycurrentRemote device OAM Channel A TX Event OAMPDU frame count
1.3.6.1.4.1.4756.20.152.40.1.124Columnf1000EASOamUniEvtChARxRemoteBread-onlycurrentRemote device OAM Channel A RX Unique Event OAMPDU frame count
1.3.6.1.4.1.4756.20.152.40.1.125Columnf1000EASOamDupEvtChARxRemoteBread-onlycurrentRemote device OAM Channel A RX Duplicate Event OAMPDU frame count
1.3.6.1.4.1.4756.20.152.40.1.126Columnf1000EASOamLbChATxRemoteBread-onlycurrentRemote device OAM Channel A TX Loopback Control OAMPDU frame count
1.3.6.1.4.1.4756.20.152.40.1.127Columnf1000EASOamLbChARxRemoteBread-onlycurrentRemote device OAM Channel A RX Loopback Control OAMPDU frame count
1.3.6.1.4.1.4756.20.152.40.1.128Columnf1000EASOamVarReqChATxRemoteBread-onlycurrentRemote device OAM Channel A TX Variable Request OAMPDU frame count
1.3.6.1.4.1.4756.20.152.40.1.129Columnf1000EASOamVarReqChARxRemoteBread-onlycurrentRemote device OAM Channel A RX Variable Request OAMPDU frame count
1.3.6.1.4.1.4756.20.152.40.1.130Columnf1000EASOamVarRspChATxRemoteBread-onlycurrentRemote device OAM Channel A TX Variable Response OAMPDU frame count
1.3.6.1.4.1.4756.20.152.40.1.131Columnf1000EASOamVarRspChARxRemoteBread-onlycurrentRemote device OAM Channel A RX Variable Response OAMPDU frame count
1.3.6.1.4.1.4756.20.152.40.1.132Columnf1000EASOamOuiChATxRemoteBread-onlycurrentRemote device OAM Channel A TX OUI OAMPDU frame count
1.3.6.1.4.1.4756.20.152.40.1.133Columnf1000EASOamOuiChARxRemoteBread-onlycurrentRemote device OAM Channel A RX OUI OAMPDU frame count
1.3.6.1.4.1.4756.20.152.40.1.134Columnf1000EASOamUnknowChARxRemoteBread-onlycurrentRemote device OAM Channel A RX Unsupported OAMPDU frame count
1.3.6.1.4.1.4756.20.152.40.1.135Columnf1000EASOamChBTxRemoteBread-onlycurrentRemote device OAM Channel B TX OAMPDU frame count
1.3.6.1.4.1.4756.20.152.40.1.136Columnf1000EASOamChBRxRemoteBread-onlycurrentRemote device OAM Channel B RX OAMPDU frame count
1.3.6.1.4.1.4756.20.152.40.1.137Columnf1000EASOamInfoChBTxRemoteBread-onlycurrentRemote device OAM Channel B TX Information OAMPDU frame count
1.3.6.1.4.1.4756.20.152.40.1.138Columnf1000EASOamInfoChBRxRemoteBread-onlycurrentRemote device OAM Channel B RX Information OAMPDU frame count
1.3.6.1.4.1.4756.20.152.40.1.139Columnf1000EASOamEventChBTxRemoteBread-onlycurrentRemote device OAM Channel B TX Event OAMPDU frame count
1.3.6.1.4.1.4756.20.152.40.1.140Columnf1000EASOamUniEvtChBRxRemoteBread-onlycurrentRemote device OAM Channel B RX Unique Event OAMPDU frame count
1.3.6.1.4.1.4756.20.152.40.1.141Columnf1000EASOamDupEvtChBRxRemoteBread-onlycurrentRemote device OAM Channel B RX Duplicate Event OAMPDU frame count
1.3.6.1.4.1.4756.20.152.40.1.142Columnf1000EASOamLbChBTxRemoteBread-onlycurrentRemote device OAM Channel B TX Loopback Control OAMPDU frame count
1.3.6.1.4.1.4756.20.152.40.1.143Columnf1000EASOamLbChBRxRemoteBread-onlycurrentRemote device OAM Channel B RX Loopback Control OAMPDU frame count
1.3.6.1.4.1.4756.20.152.40.1.144Columnf1000EASOamVarReqChBTxRemoteBread-onlycurrentRemote device OAM Channel B TX Variable Request OAMPDU frame count
1.3.6.1.4.1.4756.20.152.40.1.145Columnf1000EASOamVarReqChBRxRemoteBread-onlycurrentRemote device OAM Channel B RX Variable Request OAMPDU frame count
1.3.6.1.4.1.4756.20.152.40.1.146Columnf1000EASOamVarRspChBTxRemoteBread-onlycurrentRemote device OAM Channel B TX Variable Response OAMPDU frame count
1.3.6.1.4.1.4756.20.152.40.1.147Columnf1000EASOamVarRspChBRxRemoteBread-onlycurrentRemote device OAM Channel B RX Variable Response OAMPDU frame count
1.3.6.1.4.1.4756.20.152.40.1.148Columnf1000EASOamOuiChBTxRemoteBread-onlycurrentRemote device OAM Channel B TX OUI OAMPDU frame count
1.3.6.1.4.1.4756.20.152.40.1.149Columnf1000EASOamOuiChBRxRemoteBread-onlycurrentRemote device OAM Channel B RX OUI OAMPDU frame count
1.3.6.1.4.1.4756.20.152.40.1.150Columnf1000EASOamUnknowChBRxRemoteBread-onlycurrentRemote device OAM Channel B RX Unsupported OAMPDU frame count
1.3.6.1.4.1.4756.20.152.40.1.151Columnf1000EASFx1VLANRemoteBread-writecurrentRemoteB frm220 f1000EAS Fiber 1 VLAN group : 0:Group A 1:Group B
1.3.6.1.4.1.4756.20.152.40.1.152Columnf1000EASFx2VLANRemoteBread-writecurrentRemoteB frm220 f1000EAS Fiber 2 VLAN group : 0:Group A 1:Group B
1.3.6.1.4.1.4756.20.152.40.1.153Columnf1000EASUtp3VLANRemoteBread-writecurrentRemoteB frm220 f1000EAS UTP 3 VLAN group : 0:Group A 1:Group B
1.3.6.1.4.1.4756.20.152.40.1.154Columnf1000EASUtp4VLANRemoteBread-writecurrentRemoteB frm220 f1000EAS UTP 4 VLAN group : 0:Group A 1:Group B
1.3.6.1.4.1.4756.20.152.40.1.155Columnf1000EASManagementRemoteBread-writecurrentRemoteB frm220 f1000EAS management : 0:Group A 1:Group B 2:Group A+B
1.3.6.1.4.1.4756.20.152.40.1.156Columnf1000EASSetDefaultRemoteBread-writecurrentRemoteB frm220 f1000EAS set to default : 0:OFF 1:Actoin
1.3.6.1.4.1.4756.20.152.40.1.157Columnf1000EASPortVLANRemoteBread-writecurrentRemoteB frm220 Port VLAN : 0:Disable 1:Enable
1.3.6.1.4.1.4756.20.160NodefE1LocalCards
1.3.6.1.4.1.4756.20.160.20TablefE1LocalTablenot-accessiblecurrentA list of local FRM220-E1-ET100 series card entries. The number of entries is fE1-No-L.
1.3.6.1.4.1.4756.20.160.20.1RowfE1LocalEntrynot-accessiblecurrentAn entry containing management information applicable to a particular local FRM220- series card.
1.3.6.1.4.1.4756.20.160.20.1.1ColumnfE1ChassisIndexLocalread-onlycurrentA unique value for each local card. It is the chassis location number.
1.3.6.1.4.1.4756.20.160.20.1.2ColumnfE1SlotIndexLocalread-onlycurrentA unique value for each local card. It is the slot location number.
1.3.6.1.4.1.4756.20.160.20.1.3ColumnfE1CardHWVerLocalread-onlycurrentLocal FRM220-E1/ET100 Series card hardware version x.xxx
1.3.6.1.4.1.4756.20.160.20.1.4ColumnfE1CardFWVerLocalread-onlycurrentLocal FRM220-E1/ET100 Series card firmware version x.xxx
1.3.6.1.4.1.4756.20.160.20.1.5ColumnfE1CardCPLDVerLocalread-onlycurrentLocal FRM220-E1/ET100 Series card CPLD version x.xxx
1.3.6.1.4.1.4756.20.160.20.1.6ColumnfE1CardFPGAVerLocalread-onlycurrentLocal FRM220-E1/ET100 Series card FPGA version x.xxx
1.3.6.1.4.1.4756.20.160.20.1.7ColumnfE1PortActiveLocalread-writecurrentLocal FRM220-E1/ET100 Series card active: 0:Disable 1:Enable
1.3.6.1.4.1.4756.20.160.20.1.8ColumnfE1PortResetLocalread-writecurrentLocal FRM220-E1/ET100 Series card portreset: 0:OFF 1:Action
1.3.6.1.4.1.4756.20.160.20.1.9ColumnfE1SettoDefaultLocalread-writecurrentLocal FRM220-E1/ET100 Series card set to default: 0:OFF 1:Action
1.3.6.1.4.1.4756.20.160.20.1.10ColumnfE1SignalLocalread-onlycurrentLocal FRM220-E1/ET100 Series card E1 signal status: 0:Signal Loss 1:Normal
1.3.6.1.4.1.4756.20.160.20.1.11ColumnfE1SyncLocalread-onlycurrentLocal FRM220-E1/ET100 Series card E1 sync status: 0:Sync Loss 1:Normal
1.3.6.1.4.1.4756.20.160.20.1.12ColumnfE1RdSTSLocalread-onlycurrentLocal FRM220-E1/ET100 Series card RD status: 0:ON 1:OFF 2:Flash
1.3.6.1.4.1.4756.20.160.20.1.13ColumnfE1TdSTSLocalread-onlycurrentLocal FRM220-E1/ET100 Series card TD status: 0:ON 1:OFF 2:Flash
1.3.6.1.4.1.4756.20.160.20.1.14ColumnfE1ReAisLocalread-onlycurrentLocal FRM220-E1/ET100 Series card E1 receive AIS: 0:NO 1:Have
1.3.6.1.4.1.4756.20.160.20.1.15ColumnfE1LOMFLocalread-onlycurrentLocal FRM220-E1/ET100 Series card E1 loss of multiframe sync: 0:NO 1:Have
1.3.6.1.4.1.4756.20.160.20.1.16ColumnfE1LinecodeViolationLocalread-onlycurrentLocal FRM220-E1/ET100 Series card E1 line code violation: 0:NO 1:Have
1.3.6.1.4.1.4756.20.160.20.1.17ColumnfE1BertErrLocalread-onlycurrentLocal FRM220-E1/ET100 Series card E1 bert error: 0:NO 1:Have
1.3.6.1.4.1.4756.20.160.20.1.18ColumnfE1RemoPwAbLocalread-onlycurrentLocal FRM220-E1/ET100 Series card remote power fail: 0:OK 1:Failue
1.3.6.1.4.1.4756.20.160.20.1.19ColumnfE1Utp1LinkLocalread-onlycurrentLocal FRM220-E1/ET100 Series card utp link status: 0:Down 1:Lind up
1.3.6.1.4.1.4756.20.160.20.1.20ColumnfE1Utp1SpeedSTSLocalread-onlycurrentLocal FRM220-E1/ET100 Series card utp1 speed status : 0:10M 1:100M
1.3.6.1.4.1.4756.20.160.20.1.21ColumnfE1Utp1DuplexSTSLocalread-onlycurrentLocal FRM220-E1/ET100 Series card utp1 duplex status : 0:Half 1:Full
1.3.6.1.4.1.4756.20.160.20.1.22ColumnfE1Utp1NegLocalread-writecurrentLocal FRM220-E1/ET100 Series card utp1 negotiation : 0:Manual 1:Auto
1.3.6.1.4.1.4756.20.160.20.1.23ColumnfE1Utp1SpeedLocalread-writecurrentLocal FRM220-E1/ET100 Series card utp1 speed: 0:10M 1:100M
1.3.6.1.4.1.4756.20.160.20.1.24ColumnfE1Utp1DuplexLocalread-writecurrentLocal FRM220-E1/ET100 Series card utp1 duplex: 0:Half 1:Full
1.3.6.1.4.1.4756.20.160.20.1.25ColumnfE1Utp1FlowCrlLocalread-writecurrentLocal FRM220-E1/ET100 Series card utp1 flow control: 0:Disable 1:Enable
1.3.6.1.4.1.4756.20.160.20.1.26ColumnfE1FrameLocalread-writecurrentLocal FRM220-E1/ET100 Series card E1 frame: 0:Unframed 1:Framed
1.3.6.1.4.1.4756.20.160.20.1.27ColumnfE1TimeSlot1Localread-writecurrentLocal FRM220-E1/ET100 Series card timeslot1: 0:Inactive 1:Active
1.3.6.1.4.1.4756.20.160.20.1.28ColumnfE1TimeSlot2Localread-writecurrentLocal FRM220-E1/ET100 Series card timeslot2: 0:Inactive 1:Active
1.3.6.1.4.1.4756.20.160.20.1.29ColumnfE1TimeSlot3Localread-writecurrentLocal FRM220-E1/ET100 Series card timeslot3: 0:Inactive 1:Active
1.3.6.1.4.1.4756.20.160.20.1.30ColumnfE1TimeSlot4Localread-writecurrentLocal FRM220-E1/ET100 Series card timeslot4: 0:Inactive 1:Active
1.3.6.1.4.1.4756.20.160.20.1.31ColumnfE1TimeSlot5Localread-writecurrentLocal FRM220-E1/ET100 Series card timeslot5: 0:Inactive 1:Active
1.3.6.1.4.1.4756.20.160.20.1.32ColumnfE1TimeSlot6Localread-writecurrentLocal FRM220-E1/ET100 Series card timeslot6: 0:Inactive 1:Active
1.3.6.1.4.1.4756.20.160.20.1.33ColumnfE1TimeSlot7Localread-writecurrentLocal FRM220-E1/ET100 Series card timeslot7: 0:Inactive 1:Active
1.3.6.1.4.1.4756.20.160.20.1.34ColumnfE1TimeSlot8Localread-writecurrentLocal FRM220-E1/ET100 Series card timeslot8: 0:Inactive 1:Active
1.3.6.1.4.1.4756.20.160.20.1.35ColumnfE1TimeSlot9Localread-writecurrentLocal FRM220-E1/ET100 Series card timeslot9: 0:Inactive 1:Active
1.3.6.1.4.1.4756.20.160.20.1.36ColumnfE1TimeSlot10Localread-writecurrentLocal FRM220-E1/ET100 Series card timeslot10: 0:Inactive 1:Active
1.3.6.1.4.1.4756.20.160.20.1.37ColumnfE1TimeSlot11Localread-writecurrentLocal FRM220-E1/ET100 Series card timeslot11: 0:Inactive 1:Active
1.3.6.1.4.1.4756.20.160.20.1.38ColumnfE1TimeSlot12Localread-writecurrentLocal FRM220-E1/ET100 Series card timeslot12: 0:Inactive 1:Active
1.3.6.1.4.1.4756.20.160.20.1.39ColumnfE1TimeSlot13Localread-writecurrentLocal FRM220-E1/ET100 Series card timeslot13: 0:Inactive 1:Active
1.3.6.1.4.1.4756.20.160.20.1.40ColumnfE1TimeSlot14Localread-writecurrentLocal FRM220-E1/ET100 Series card timeslot14: 0:Inactive 1:Active
1.3.6.1.4.1.4756.20.160.20.1.41ColumnfE1TimeSlot15Localread-writecurrentLocal FRM220-E1 Series card timeslot15: 0:Inactive 1:Active
1.3.6.1.4.1.4756.20.160.20.1.42ColumnfE1TimeSlot16Localread-writecurrentLocal FRM220-E1 Series card timeslot16: 0:Inactive 1:Active
1.3.6.1.4.1.4756.20.160.20.1.43ColumnfE1TimeSlot17Localread-writecurrentLocal FRM220-E1/ET100 Series card timeslot17: 0:Inactive 1:Active
1.3.6.1.4.1.4756.20.160.20.1.44ColumnfE1TimeSlot18Localread-writecurrentLocal FRM220-E1/ET100 Series card timeslot18: 0:Inactive 1:Active
1.3.6.1.4.1.4756.20.160.20.1.45ColumnfE1TimeSlot19Localread-writecurrentLocal FRM220-E1/ET100 Series card timeslot19: 0:Inactive 1:Active
1.3.6.1.4.1.4756.20.160.20.1.46ColumnfE1TimeSlot20Localread-writecurrentLocal FRM220-E1/ET100 Series card timeslot20: 0:Inactive 1:Active
1.3.6.1.4.1.4756.20.160.20.1.47ColumnfE1TimeSlot21Localread-writecurrentLocal FRM220-E1/ET100 Series card timeslot21: 0:Inactive 1:Active
1.3.6.1.4.1.4756.20.160.20.1.48ColumnfE1TimeSlot22Localread-writecurrentLocal FRM220-E1/ET100 Series card timeslot22: 0:Inactive 1:Active
1.3.6.1.4.1.4756.20.160.20.1.49ColumnfE1TimeSlot23Localread-writecurrentLocal FRM220-E1/ET100 Series card timeslot23: 0:Inactive 1:Active
1.3.6.1.4.1.4756.20.160.20.1.50ColumnfE1TimeSlot24Localread-writecurrentLocal FRM220-E1/ET100 Series card timeslot24: 0:Inactive 1:Active
1.3.6.1.4.1.4756.20.160.20.1.51ColumnfE1TimeSlot25Localread-writecurrentLocal FRM220-E1/ET100 Series card timeslot25: 0:Inactive 1:Active
1.3.6.1.4.1.4756.20.160.20.1.52ColumnfE1TimeSlot26Localread-writecurrentLocal FRM220-E1/ET100 Series card timeslot26: 0:Inactive 1:Active
1.3.6.1.4.1.4756.20.160.20.1.53ColumnfE1TimeSlot27Localread-writecurrentLocal FRM220-E1/ET100 Series card timeslot27: 0:Inactive 1:Active
1.3.6.1.4.1.4756.20.160.20.1.54ColumnfE1TimeSlot28Localread-writecurrentLocal FRM220-E1/ET100 Series card timeslot28: 0:Inactive 1:Active
1.3.6.1.4.1.4756.20.160.20.1.55ColumnfE1TimeSlot29Localread-writecurrentLocal FRM220-E1/ET100 Series card timeslot29: 0:Inactive 1:Active
1.3.6.1.4.1.4756.20.160.20.1.56ColumnfE1TimeSlot30Localread-writecurrentLocal FRM220-E1/ET100 Series card timeslot30: 0:Inactive 1:Active
1.3.6.1.4.1.4756.20.160.20.1.57ColumnfE1TimeSlot31Localread-writecurrentLocal FRM220-E1/ET100 Series card timeslot31: 0:Inactive 1:Active
1.3.6.1.4.1.4756.20.160.20.1.58ColumnfE1TimeSourceLocalread-writecurrentLocal FRM220-E1/ET100 Series card time souce: 0:Recovery from E1 1:Internal oscillator
1.3.6.1.4.1.4756.20.160.20.1.59ColumnfE1FramerLocalread-writecurrentLocal FRM220-E1/ET100 Series card E1 framer: 0:CCS 1:CAS
1.3.6.1.4.1.4756.20.160.20.1.60ColumnfE1LinecodeLocalread-writecurrentLocal FRM220-E1/ET100 Series card E1 line code: 0:HDB3 1:AMI
1.3.6.1.4.1.4756.20.160.20.1.61ColumnfE1LineImpedanceLocalread-writecurrentLocal FRM220-E1/ET100 Series card E1 line impedance: 0:120 ohms 1:75 ohms
1.3.6.1.4.1.4756.20.160.20.1.62ColumnfE1IdelCodeLocalread-writecurrentLocal FRM220-E1/ET100 Series card E1 unused timeslot code: 0:0x7E 1:0xFF
1.3.6.1.4.1.4756.20.160.20.1.63ColumnfE1AisLocalread-writecurrentLocal FRM220-E1/ET100 Series card E1 AIS: 0:Disable 1:Enable
1.3.6.1.4.1.4756.20.160.20.1.64ColumnfE1LbsettingLocalread-writecurrentLocal FRM220-E1/ET100 Series card loop back test: 0:OFF 1:RLB 2:RRLB
1.3.6.1.4.1.4756.20.160.20.1.65ColumnfE1BertLocalread-writecurrentLocal FRM220-E1/ET100 Series card bert test: 0:Disable 1:Enable
1.3.6.1.4.1.4756.20.160.20.1.66ColumnfE1CounterCrlLocalread-writecurrentLocal FRM220-E1/ET100 Series card counter control: 0:Disable 1:Enable
1.3.6.1.4.1.4756.20.160.20.1.67ColumnfE1RmonInLocalread-onlycurrentLocal FRM220-E1/ET100 Series card RMON Rx counter:
1.3.6.1.4.1.4756.20.160.20.1.68ColumnfE1RmonOutLocalread-onlycurrentLocal FRM220-E1/ET100 Series card RMON Rx counter:
1.3.6.1.4.1.4756.20.160.20.1.69ColumnfE1CrlRmonCntsRxLocalread-writecurrentLocal FRM220-E1/ET100 Series card clear RMON Rx: 0:NO 1:Clear
1.3.6.1.4.1.4756.20.160.20.1.70ColumnfE1CrlRmonCntsTxLocalread-writecurrentLocal FRM220-E1/ET100 Series card clear RMON Tx: 0:NO 1:Clear
1.3.6.1.4.1.4756.20.160.20.1.71ColumnfE1TestSTSLocalread-onlycurrentLocal FRM220-E1/ET100 Series card test status: 0:Normal 1:In test
1.3.6.1.4.1.4756.20.160.20.1.72ColumnfE1AlarmSTSLocalread-onlycurrentLocal FRM220-E1/ET100 Series card E1 alarm status: 0:No 1:Have
1.3.6.1.4.1.4756.20.161NodefE1RemoteCards
1.3.6.1.4.1.4756.20.161.20TablefE1RemoteTablenot-accessiblecurrentA list of local FRM220-E1-ET100 series card entries. The number of entries is fE1-No-L.
1.3.6.1.4.1.4756.20.161.20.1RowfE1RemoteEntrynot-accessiblecurrentAn entry containing management information applicable to a particular local FRM220-E1/ET100 series card.
1.3.6.1.4.1.4756.20.161.20.1.1ColumnfE1ChassisIndexRemoteread-onlycurrentA unique value for each local card. It is the chassis location number.
1.3.6.1.4.1.4756.20.161.20.1.2ColumnfE1SlotIndexRemoteread-onlycurrentA unique value for each local card. It is the slot location number.
1.3.6.1.4.1.4756.20.161.20.1.3ColumnfE1CardHWVerRemoteread-onlycurrentRemote FRM220-E1/ET100 Series card hardware version x.xxx
1.3.6.1.4.1.4756.20.161.20.1.4ColumnfE1CardFWVerRemoteread-onlycurrentRemote FRM220-E1/ET100 Series card firmware version x.xxx
1.3.6.1.4.1.4756.20.161.20.1.5ColumnfE1CardCPLDVerRemoteread-onlycurrentRemote FRM220-E1/ET100 Series card CPLD version x.xxx
1.3.6.1.4.1.4756.20.161.20.1.6ColumnfE1CardFPGAVerRemoteread-onlycurrentRemote FRM220-E1/ET100 Series card FPGA version x.xxx
1.3.6.1.4.1.4756.20.161.20.1.7ColumnfE1PortActiveRemoteread-onlycurrentRemote FRM220-E1/ET100 Series card active: 0:Disable 1:Enable
1.3.6.1.4.1.4756.20.161.20.1.8ColumnfE1PortResetRemoteread-writecurrentRemote FRM220-E1/ET100 Series card portreset: 0:OFF 1:Action
1.3.6.1.4.1.4756.20.161.20.1.9ColumnfE1SettoDefaultRemoteread-writecurrentRemote FRM220-E1/ET100 Series card set to default: 0:OFF 1:Action
1.3.6.1.4.1.4756.20.161.20.1.10ColumnfE1SignalRemoteread-onlycurrentRemote FRM220-E1/ET100 Series card E1 signal status: 0:Signal Loss 1:Normal
1.3.6.1.4.1.4756.20.161.20.1.11ColumnfE1SyncRemoteread-onlycurrentRemote FRM220-E1/ET100 Series card E1 sync status: 0:Sync Loss 1:Normal
1.3.6.1.4.1.4756.20.161.20.1.12ColumnfE1RdSTSRemoteread-onlycurrentRemote FRM220-E1/ET100 Series card RD status: 0:ON 1:OFF 2:Flash
1.3.6.1.4.1.4756.20.161.20.1.13ColumnfE1TdSTSRemoteread-onlycurrentRemote FRM220-E1/ET100 Series card TD status: 0:ON 1:OFF 2:Flash
1.3.6.1.4.1.4756.20.161.20.1.14ColumnfE1ReAisRemoteread-onlycurrentRemote FRM220-E1/ET100 Series card E1 receive AIS: 0:NO 1:Have
1.3.6.1.4.1.4756.20.161.20.1.15ColumnfE1LOMFRemoteread-onlycurrentRemote FRM220-E1/ET100 Series card E1 loss of multiframe sync: 0:NO 1:Have
1.3.6.1.4.1.4756.20.161.20.1.16ColumnfE1LinecodeViolationRemoteread-onlycurrentRemote FRM220-E1/ET100 Series card E1 line code violation: 0:NO 1:Have
1.3.6.1.4.1.4756.20.161.20.1.17ColumnfE1BertErrRemoteread-onlycurrentRemote FRM220-E1/ET100 Series card E1 bert error: 0:NO 1:Have
1.3.6.1.4.1.4756.20.161.20.1.18ColumnfE1RemoPwAbRemoteread-onlycurrentRemote FRM220-E1/ET100 Series card remote power fail: 0:OK 1:Failue
1.3.6.1.4.1.4756.20.161.20.1.19ColumnfE1Utp1LinkRemoteread-onlycurrentRemote FRM220-E1/ET100 Series card utp link status: 0:Down 1:Lind up
1.3.6.1.4.1.4756.20.161.20.1.20ColumnfE1Utp1SpeedSTSRemoteread-onlycurrentRemote FRM220-E1/ET100 Series card utp1 speed status : 0:10M 1:100M
1.3.6.1.4.1.4756.20.161.20.1.21ColumnfE1Utp1DuplexSTSRemoteread-onlycurrentRemote FRM220-E1/ET100 Series card utp1 duplex status : 0:Half 1:Full
1.3.6.1.4.1.4756.20.161.20.1.22ColumnfE1Utp1NegRemoteread-writecurrentRemote FRM220-E1/ET100 Series card utp1 negotiation : 0:Manual 1:Auto
1.3.6.1.4.1.4756.20.161.20.1.23ColumnfE1Utp1SpeedRemoteread-writecurrentRemote FRM220-E1/ET100 Series card utp1 speed: 0:10M 1:100M
1.3.6.1.4.1.4756.20.161.20.1.24ColumnfE1Utp1DuplexRemoteread-writecurrentRemote FRM220-E1/ET100 Series card utp1 duplex: 0:Half 1:Full
1.3.6.1.4.1.4756.20.161.20.1.25ColumnfE1Utp1FlowCrlRemoteread-writecurrentRemote FRM220-E1/ET100 Series card utp1 flow control: 0:Disable 1:Enable
1.3.6.1.4.1.4756.20.161.20.1.26ColumnfE1FrameRemoteread-onlycurrentRemote FRM220-E1/ET100 Series card E1 frame: 0:Unframed 1:Framed
1.3.6.1.4.1.4756.20.161.20.1.27ColumnfE1TimeSlot1Remoteread-writecurrentRemote FRM220-E1/ET100 Series card timeslot1: 0:Inactive 1:Active
1.3.6.1.4.1.4756.20.161.20.1.28ColumnfE1TimeSlot2Remoteread-writecurrentRemote FRM220-E1/ET100 Series card timeslot2: 0:Inactive 1:Active
1.3.6.1.4.1.4756.20.161.20.1.29ColumnfE1TimeSlot3Remoteread-writecurrentRemote FRM220-E1/ET100 Series card timeslot3: 0:Inactive 1:Active
1.3.6.1.4.1.4756.20.161.20.1.30ColumnfE1TimeSlot4Remoteread-writecurrentRemote FRM220-E1/ET100 Series card timeslot4: 0:Inactive 1:Active
1.3.6.1.4.1.4756.20.161.20.1.31ColumnfE1TimeSlot5Remoteread-writecurrentRemote FRM220-E1/ET100 Series card timeslot5: 0:Inactive 1:Active
1.3.6.1.4.1.4756.20.161.20.1.32ColumnfE1TimeSlot6Remoteread-writecurrentRemote FRM220-E1/ET100 Series card timeslot6: 0:Inactive 1:Active
1.3.6.1.4.1.4756.20.161.20.1.33ColumnfE1TimeSlot7Remoteread-writecurrentRemote FRM220-E1/ET100 Series card timeslot7: 0:Inactive 1:Active
1.3.6.1.4.1.4756.20.161.20.1.34ColumnfE1TimeSlot8Remoteread-writecurrentRemote FRM220-E1/ET100 Series card timeslot8: 0:Inactive 1:Active
1.3.6.1.4.1.4756.20.161.20.1.35ColumnfE1TimeSlot9Remoteread-writecurrentRemote FRM220-E1/ET100 Series card timeslot9: 0:Inactive 1:Active
1.3.6.1.4.1.4756.20.161.20.1.36ColumnfE1TimeSlot10Remoteread-writecurrentRemote FRM220-E1/ET100 Series card timeslot10: 0:Inactive 1:Active
1.3.6.1.4.1.4756.20.161.20.1.37ColumnfE1TimeSlot11Remoteread-writecurrentRemote FRM220-E1/ET100 Series card timeslot11: 0:Inactive 1:Active
1.3.6.1.4.1.4756.20.161.20.1.38ColumnfE1TimeSlot12Remoteread-writecurrentRemote FRM220-E1/ET100 Series card timeslot12: 0:Inactive 1:Active
1.3.6.1.4.1.4756.20.161.20.1.39ColumnfE1TimeSlot13Remoteread-writecurrentRemote FRM220-E1/ET100 Series card timeslot13: 0:Inactive 1:Active
1.3.6.1.4.1.4756.20.161.20.1.40ColumnfE1TimeSlot14Remoteread-writecurrentRemote FRM220-E1/ET100 Series card timeslot14: 0:Inactive 1:Active
1.3.6.1.4.1.4756.20.161.20.1.41ColumnfE1TimeSlot15Remoteread-writecurrentRemote FRM220-E1 Series card timeslot15: 0:Inactive 1:Active
1.3.6.1.4.1.4756.20.161.20.1.42ColumnfE1TimeSlot16Remoteread-writecurrentRemote FRM220-E1 Series card timeslot16: 0:Inactive 1:Active
1.3.6.1.4.1.4756.20.161.20.1.43ColumnfE1TimeSlot17Remoteread-writecurrentRemote FRM220-E1/ET100 Series card timeslot17: 0:Inactive 1:Active
1.3.6.1.4.1.4756.20.161.20.1.44ColumnfE1TimeSlot18Remoteread-writecurrentRemote FRM220-E1/ET100 Series card timeslot18: 0:Inactive 1:Active
1.3.6.1.4.1.4756.20.161.20.1.45ColumnfE1TimeSlot19Remoteread-writecurrentRemote FRM220-E1/ET100 Series card timeslot19: 0:Inactive 1:Active
1.3.6.1.4.1.4756.20.161.20.1.46ColumnfE1TimeSlot20Remoteread-writecurrentRemote FRM220-E1/ET100 Series card timeslot20: 0:Inactive 1:Active
1.3.6.1.4.1.4756.20.161.20.1.47ColumnfE1TimeSlot21Remoteread-writecurrentRemote FRM220-E1/ET100 Series card timeslot21: 0:Inactive 1:Active
1.3.6.1.4.1.4756.20.161.20.1.48ColumnfE1TimeSlot22Remoteread-writecurrentRemote FRM220-E1/ET100 Series card timeslot22: 0:Inactive 1:Active
1.3.6.1.4.1.4756.20.161.20.1.49ColumnfE1TimeSlot23Remoteread-writecurrentRemote FRM220-E1/ET100 Series card timeslot23: 0:Inactive 1:Active
1.3.6.1.4.1.4756.20.161.20.1.50ColumnfE1TimeSlot24Remoteread-writecurrentRemote FRM220-E1/ET100 Series card timeslot24: 0:Inactive 1:Active
1.3.6.1.4.1.4756.20.161.20.1.51ColumnfE1TimeSlot25Remoteread-writecurrentRemote FRM220-E1/ET100 Series card timeslot25: 0:Inactive 1:Active
1.3.6.1.4.1.4756.20.161.20.1.52ColumnfE1TimeSlot26Remoteread-writecurrentRemote FRM220-E1/ET100 Series card timeslot26: 0:Inactive 1:Active
1.3.6.1.4.1.4756.20.161.20.1.53ColumnfE1TimeSlot27Remoteread-writecurrentRemote FRM220-E1/ET100 Series card timeslot27: 0:Inactive 1:Active
1.3.6.1.4.1.4756.20.161.20.1.54ColumnfE1TimeSlot28Remoteread-writecurrentRemote FRM220-E1/ET100 Series card timeslot28: 0:Inactive 1:Active
1.3.6.1.4.1.4756.20.161.20.1.55ColumnfE1TimeSlot29Remoteread-writecurrentRemote FRM220-E1/ET100 Series card timeslot29: 0:Inactive 1:Active
1.3.6.1.4.1.4756.20.161.20.1.56ColumnfE1TimeSlot30Remoteread-writecurrentRemote FRM220-E1/ET100 Series card timeslot30: 0:Inactive 1:Active
1.3.6.1.4.1.4756.20.161.20.1.57ColumnfE1TimeSlot31Remoteread-writecurrentRemote FRM220-E1/ET100 Series card timeslot31: 0:Inactive 1:Active
1.3.6.1.4.1.4756.20.161.20.1.58ColumnfE1TimeSourceRemoteread-writecurrentRemote FRM220-E1/ET100 Series card time souce: 0:Recovery from E1 1:Internal oscillator
1.3.6.1.4.1.4756.20.161.20.1.59ColumnfE1FramerRemoteread-writecurrentRemote FRM220-E1/ET100 Series card E1 framer: 0:CCS 1:CAS
1.3.6.1.4.1.4756.20.161.20.1.60ColumnfE1LinecodeRemoteread-writecurrentRemote FRM220-E1/ET100 Series card E1 line code: 0:HDB3 1:AMI
1.3.6.1.4.1.4756.20.161.20.1.61ColumnfE1LineImpedanceRemoteread-writecurrentRemote FRM220-E1/ET100 Series card E1 line impedance: 0:120 ohms 1:75 ohms
1.3.6.1.4.1.4756.20.161.20.1.62ColumnfE1IdelCodeRemoteread-writecurrentRemote FRM220-E1/ET100 Series card E1 unused timeslot code: 0:0x7E 1:0xFF
1.3.6.1.4.1.4756.20.161.20.1.63ColumnfE1AisRemoteread-writecurrentRemote FRM220-E1/ET100 Series card E1 AIS: 0:Disable 1:Enable
1.3.6.1.4.1.4756.20.161.20.1.64ColumnfE1CounterCrlRemoteread-writecurrentRemote FRM220-E1/ET100 Series card counter control: 0:Disable 1:Enable
1.3.6.1.4.1.4756.20.161.20.1.65ColumnfE1RmonInRemoteread-onlycurrentRemote FRM220-E1/ET100 Series card RMON Rx counter:
1.3.6.1.4.1.4756.20.161.20.1.66ColumnfE1RmonOutRemoteread-onlycurrentRemote FRM220-E1/ET100 Series card RMON Rx counter:
1.3.6.1.4.1.4756.20.161.20.1.67ColumnfE1CrlRmonCntsRxRemoteread-writecurrentRemote FRM220-E1/ET100 Series card clear RMON Rx: 0:NO 1:Clear
1.3.6.1.4.1.4756.20.161.20.1.68ColumnfE1CrlRmonCntsTxRemoteread-writecurrentRemote FRM220-E1/ET100 Series card clear RMON Tx: 0:NO 1:Clear
1.3.6.1.4.1.4756.20.161.20.1.69ColumnfE1TestSTSRemoteread-onlycurrentRemote FRM220-E1/ET100 Series card test status: 0:Normal 1:In test
1.3.6.1.4.1.4756.20.161.20.1.70ColumnfE1AlarmSTSRemoteread-onlycurrentRemote FRM220-E1/ET100 Series card E1 alarm status: 0:No 1:Have
1.3.6.1.4.1.4756.20.170Nodef1000EDSCards
1.3.6.1.4.1.4756.20.170.20Tablef1000EDSTablenot-accessiblecurrentA list of local frm220-1000EDS card entries. The number of entries is f1000EDS-No.
1.3.6.1.4.1.4756.20.170.20.1Rowf1000EDSEntrynot-accessiblecurrentAn entry containing management information applicable to a particular local FRM-1000EDS card.
1.3.6.1.4.1.4756.20.170.20.1.1Columnf1000EDSChassisIndexread-onlycurrentA unique value for each local card. It is the chassis location number.
1.3.6.1.4.1.4756.20.170.20.1.2Columnf1000EDSSlotIndexread-onlycurrentA unique value for each local card. It is the slot location number.
1.3.6.1.4.1.4756.20.170.20.1.3Columnf1000EDSCardHWVerread-onlycurrentdevice card hardware version x.xxx
1.3.6.1.4.1.4756.20.170.20.1.4Columnf1000EDSCardFWVerread-onlycurrentdevice card firmware version x.xxx
1.3.6.1.4.1.4756.20.170.20.1.5Columnf1000EDSCardCPLDVerread-onlycurrentdevice card CPLD version x.xxx
1.3.6.1.4.1.4756.20.170.20.1.6Columnf1000EDSCardFPGAVerread-onlycurrentdevice card FPGA version x.xxx
1.3.6.1.4.1.4756.20.170.20.1.7Columnf1000EDSModelread-onlycurrentfrm220 f1000EDS Serial Type
1.3.6.1.4.1.4756.20.170.20.1.8Columnf1000EDSFx1Linkread-onlycurrentdevice card fiber port 1 link status: 0:Down 1:Up
1.3.6.1.4.1.4756.20.170.20.1.9Columnf1000EDSFx1FEFread-onlycurrentdevice card fiber port 1 detected Far End Fault: 0:Off 1:Detected
1.3.6.1.4.1.4756.20.170.20.1.10Columnf1000EDSFx1RemoPwrAbread-onlycurrentdevice card fiber port 1 Remote Power status: 0:Abnormal 1:OK
1.3.6.1.4.1.4756.20.170.20.1.11Columnf1000EDSFx2Linkread-onlycurrentdevice card fiber port 2 link status: 0:Down 1:Up
1.3.6.1.4.1.4756.20.170.20.1.12Columnf1000EDSFx2FEFread-onlycurrentdevice card fiber port 2 detected Far End Fault: 0:Off 1:Detected
1.3.6.1.4.1.4756.20.170.20.1.13Columnf1000EDSFx2RemoPwrAbread-onlycurrentdevice card fiber port 2 Remote Power status: 0:Abnormal 1:OK
1.3.6.1.4.1.4756.20.170.20.1.14Columnf1000EDSUtp1Linkread-onlycurrentdevice card UTP port 3 link status: 0:Down 1:Up
1.3.6.1.4.1.4756.20.170.20.1.15Columnf1000EDSUtp1Negoread-writecurrentdevice card UTP port 3 negotiation status: 0:Manual 1:Auto
1.3.6.1.4.1.4756.20.170.20.1.16Columnf1000EDSUtp1Speedread-writecurrentdevice card UTP port 3 speed status: 0:10 Base-T 1:100 Base-TX 2:1000 Base-TX
1.3.6.1.4.1.4756.20.170.20.1.17Columnf1000EDSUtp1Duplexread-writecurrentdevice card UTP port 3 duplex status: 0:Half duplex mode 1:Full duplex mode
1.3.6.1.4.1.4756.20.170.20.1.18Columnf1000EDSUtp2Linkread-onlycurrentdevice card UTP port 4 link status: 0:Down 1:Up
1.3.6.1.4.1.4756.20.170.20.1.19Columnf1000EDSUtp2Negoread-writecurrentdevice card UTP port 4 negotiation status: 0:Manual 1:Auto
1.3.6.1.4.1.4756.20.170.20.1.20Columnf1000EDSUtp2Speedread-writecurrentdevice card UTP port 4 speed status: 0:10 Base-T 1:100 Base-TX 2:1000 Base-TX
1.3.6.1.4.1.4756.20.170.20.1.21Columnf1000EDSUtp2Duplexread-writecurrentdevice card UTP port 4 duplex status: 0:Half duplex mode 1:Full duplex mode
1.3.6.1.4.1.4756.20.170.20.1.22Columnf1000EDSFx1IrlModeread-writecurrentdevice card port 1 Ingress Rate Limit mode: (Ingress data rate limit for priority 0 frames.) 0:No limit 1:limited
1.3.6.1.4.1.4756.20.170.20.1.23Columnf1000EDSFx1IrlIndexread-writecurrentdevice card port 1 Ingress Rate Limit index: Index Limit Rate Index Limit Rate 0 Disable 16 1M 1 250M 17 960K 2 140M 18 896K 3 95M 19 832K 4 57M 20 768K 5 40M …
1.3.6.1.4.1.4756.20.170.20.1.24Columnf1000EDSFx1ErlIndexread-writecurrentdevice card port 1 Egress Rate Limit index: Index Limit Rate Index Limit Rate 0 Disable 16 1M 1 250M 17 960K 2 140M 18 896K 3 95M 19 832K 4 57M 20 768K 5 40M 2…
1.3.6.1.4.1.4756.20.170.20.1.25Columnf1000EDSFx2IrlModeread-writecurrentdevice card port 2 Ingress Rate Limit mode: (Ingress data rate limit for priority 0 frames.) 0:No limit 1:limited
1.3.6.1.4.1.4756.20.170.20.1.26Columnf1000EDSFx2IrlIndexread-writecurrentdevice card port 2 Ingress Rate Limit index: Index Limit Rate Index Limit Rate 0 Disable 16 1M 1 250M 17 960K 2 140M 18 896K 3 95M 19 832K 4 57M 20 768K 5 40M …
1.3.6.1.4.1.4756.20.170.20.1.27Columnf1000EDSFx2ErlIndexread-writecurrentdevice card port 2 Egress Rate Limit index: Index Limit Rate Index Limit Rate 0 Disable 16 1M 1 250M 17 960K 2 140M 18 896K 3 95M 19 832K 4 57M 20 768K 5 40M 2…
1.3.6.1.4.1.4756.20.170.20.1.28Columnf1000EDSUtp1IrlModeread-writecurrentdevice card port 3 Ingress Rate Limit mode: (Ingress data rate limit for priority 0 frames.) 0:No limit 1:limited
1.3.6.1.4.1.4756.20.170.20.1.29Columnf1000EDSUtp1IrlIndexread-writecurrentdevice card port 3 Ingress Rate Limit index: Index Limit Rate Index Limit Rate 0 Disable 16 1M 1 250M 17 960K 2 140M 18 896K 3 95M 19 832K 4 57M 20 768K 5 40M …
1.3.6.1.4.1.4756.20.170.20.1.30Columnf1000EDSUtp1ErlIndexread-writecurrentdevice card port 3 Egress Rate Limit index: Index Limit Rate Index Limit Rate 0 Disable 16 1M 1 250M 17 960K 2 140M 18 896K 3 95M 19 832K 4 57M 20 768K 5 40M 2…
1.3.6.1.4.1.4756.20.170.20.1.31Columnf1000EDSUtp2IrlModeread-writecurrentdevice card port 4 Ingress Rate Limit mode: (Ingress data rate limit for priority 0 frames.) 0:No limit 1:limited
1.3.6.1.4.1.4756.20.170.20.1.32Columnf1000EDSUtp2IrlIndexread-writecurrentdevice card port 4 Ingress Rate Limit index: Index Limit Rate Index Limit Rate 0 Disable 16 1M 1 250M 17 960K 2 140M 18 896K 3 95M 19 832K 4 57M 20 768K 5 40M …
1.3.6.1.4.1.4756.20.170.20.1.33Columnf1000EDSUtp2ErlIndexread-writecurrentdevice card port 4 Egress Rate Limit index: Index Limit Rate Index Limit Rate 0 Disable 16 1M 1 250M 17 960K 2 140M 18 896K 3 95M 19 832K 4 57M 20 768K 5 40M 2…
1.3.6.1.4.1.4756.20.170.20.1.34Columnf1000EDSDeviceActiveread-writecurrentdevice card active mode: (It is read-only in local device.) 0:Disable 1:Enable
1.3.6.1.4.1.4756.20.170.20.1.35Columnf1000EDSDeviceResetread-writecurrentForce local device card to reset mode: 0:Off 1:Action
1.3.6.1.4.1.4756.20.170.20.1.36Columnf1000EDSFx1Activeread-writecurrentdevice fiber port 1 active mode: 0:Disable 1:Enable
1.3.6.1.4.1.4756.20.170.20.1.37Columnf1000EDSFx2Activeread-writecurrentdevice fiber port 2 active mode: 0:Disable 1:Enable
1.3.6.1.4.1.4756.20.170.20.1.38Columnf1000EDSUtp1Activeread-writecurrentdevice UTP port 3 active mode: 0:Disable 1:Enable
1.3.6.1.4.1.4756.20.170.20.1.39Columnf1000EDSUtp2Activeread-writecurrentdevice UTP port 4 active mode: 0:Disable 1:Enable
1.3.6.1.4.1.4756.20.170.20.1.40Columnf1000EDSOperationModeread-writecurrentdevice operation mode setting 0:Switch Mode 1:Port VLAN Mode
1.3.6.1.4.1.4756.20.170.20.1.41Columnf1000EDSLfpMode1read-writecurrentdevice card port 1 Link Fault Pass Through: 0:Disable 1:Enable
1.3.6.1.4.1.4756.20.170.20.1.42Columnf1000EDSLfpMode2read-writecurrentdevice card port 2 Link Fault Pass Through: 0:Disable 1:Enable
1.3.6.1.4.1.4756.20.170.20.1.43Columnf1000EDSFx1AlsMode1read-writecurrentdevice card port 1 Auto Laser Shutdown mode: 0:Disable 1:Enable
1.3.6.1.4.1.4756.20.170.20.1.44Columnf1000EDSFx2AlsMode2read-writecurrentdevice card port 2 Auto Laser Shutdown mode: 0:Disable 1:Enable
1.3.6.1.4.1.4756.20.170.20.1.45Columnf1000EDSClrRMONCntsread-writecurrentClear local device card RMON IN/OUT counters: 0:No action 1:Action
1.3.6.1.4.1.4756.20.170.20.1.46Columnf1000EDSFx1InfoROM1read-onlycurrentdevice card port 1 INFORemoteOM information 1 valid: 0:Invalid 1:Valid
1.3.6.1.4.1.4756.20.170.20.1.47Columnf1000EDSFx1InfoROM2read-onlycurrentdevice card port 1 INFORemoteOM information 2 valid: 0:Invalid 1:Valid(replacing D/D function
1.3.6.1.4.1.4756.20.170.20.1.48Columnf1000EDSFx2InfoROM2read-onlycurrentdevice card port 2 INFORemoteOM information 2 valid: 0:Invalid 1:Valid(replacing D/D function)
1.3.6.1.4.1.4756.20.170.20.1.49Columnf1000EDSFx1InfoSN1read-onlycurrentdevice card port 1 INFORemoteOM S/N 1
1.3.6.1.4.1.4756.20.170.20.1.50Columnf1000EDSFx1InfoSN2read-onlycurrentdevice card port 1 INFORemoteOM S/N 2
1.3.6.1.4.1.4756.20.170.20.1.51Columnf1000EDSFx2InfoSN1read-onlycurrentdevice card port 2 INFORemoteOM S/N 1
1.3.6.1.4.1.4756.20.170.20.1.52Columnf1000EDSFx2InfoSN2read-onlycurrentdevice card port 2 INFORemoteOM S/N 2
1.3.6.1.4.1.4756.20.170.20.1.53Columnf1000EDSFx1DDread-onlycurrentdevice card fiber port 1 Digital Diagnostic function: 0:No 1:Yes
1.3.6.1.4.1.4756.20.170.20.1.54Columnf1000EDSFx1DDVendorread-onlycurrentdevice card fiber port 1 D/D information: Vendor name
1.3.6.1.4.1.4756.20.170.20.1.55Columnf1000EDSFx1DDPartNoread-onlycurrentdevice card fiber port 1 D/D information: Vendor part number
1.3.6.1.4.1.4756.20.170.20.1.56Columnf1000EDSFx1DDFiberTyperead-onlycurrentdevice card fiber port 1 D/D information: Fiber Type
1.3.6.1.4.1.4756.20.170.20.1.57Columnf1000EDSFx1DDWaveLenread-onlycurrentdevice card fiber port 1 D/D information: Wave length
1.3.6.1.4.1.4756.20.170.20.1.58Columnf1000EDSFx1DDWaveLen2read-onlycurrentdevice card fiber port 1 D/D information: Wave length 2
1.3.6.1.4.1.4756.20.170.20.1.59Columnf1000EDSFx1DDLinkLenread-onlycurrentdevice card fiber port 1 D/D information: Link length
1.3.6.1.4.1.4756.20.170.20.1.60Columnf1000EDSFx1DDLenUnitread-onlycurrentdevice card fiber port 1 D/D information: Length Unit
1.3.6.1.4.1.4756.20.170.20.1.61Columnf1000EDSFx1DDStatusread-onlycurrentdevice card fiber port 1 D/D information: Status Support
1.3.6.1.4.1.4756.20.170.20.1.62Columnf1000EDSFx1DDRxSensread-onlycurrentdevice card fiber port 1 D/D information: Rx Sensitivity
1.3.6.1.4.1.4756.20.170.20.1.63Columnf1000EDSFx1DDTxPWRread-onlycurrentdevice card fiber port 1 D/D information: Tx power
1.3.6.1.4.1.4756.20.170.20.1.64Columnf1000EDSFx1DDRxPWRread-onlycurrentdevice card fiber port 1 D/D information: Rx power
1.3.6.1.4.1.4756.20.170.20.1.65Columnf1000EDSFx1DDTempread-onlycurrentdevice card fiber port 1 D/D information: Temperature in degree C
1.3.6.1.4.1.4756.20.170.20.1.66Columnf1000EDSFx1DDPWRMarginread-onlycurrentdevice card fiber port 1 D/D information: Power margin
1.3.6.1.4.1.4756.20.170.20.1.67Columnf1000EDSFx2DDread-onlycurrentdevice card fiber port 2 Digital Diagnostic function: 0:No 1:Yes
1.3.6.1.4.1.4756.20.170.20.1.68Columnf1000EDSFx2DDVendorread-onlycurrentdevice card fiber port 2 D/D information: Vendor name
1.3.6.1.4.1.4756.20.170.20.1.69Columnf1000EDSFx2DDPartNoread-onlycurrentdevice card fiber port 2 D/D information: Vendor part number
1.3.6.1.4.1.4756.20.170.20.1.70Columnf1000EDSFx2DDFiberTyperead-onlycurrentdevice card fiber port 2 D/D information: Fiber Type
1.3.6.1.4.1.4756.20.170.20.1.71Columnf1000EDSFx2DDWaveLenread-onlycurrentdevice card fiber port 2 D/D information: Wave length
1.3.6.1.4.1.4756.20.170.20.1.72Columnf1000EDSFx2DDWaveLen2read-onlycurrentdevice card fiber port 2 D/D information: Wave length 2
1.3.6.1.4.1.4756.20.170.20.1.73Columnf1000EDSFx2DDLinkLenread-onlycurrentdevice card fiber port 2 D/D information: Link length
1.3.6.1.4.1.4756.20.170.20.1.74Columnf1000EDSFx2DDLenUnitread-onlycurrentdevice card fiber port 2 D/D information: Length Unit
1.3.6.1.4.1.4756.20.170.20.1.75Columnf1000EDSFx2DDStatusread-onlycurrentdevice card fiber port 2 D/D information: Status Support
1.3.6.1.4.1.4756.20.170.20.1.76Columnf1000EDSFx2DDRxSensread-onlycurrentdevice card fiber port 2 D/D information: Rx Sensitivity
1.3.6.1.4.1.4756.20.170.20.1.77Columnf1000EDSFx2DDTxPWRread-onlycurrentdevice card fiber port 2 D/D information: Tx power
1.3.6.1.4.1.4756.20.170.20.1.78Columnf1000EDSFx2DDRxPWRread-onlycurrentdevice card fiber port 2 D/D information: Rx power
1.3.6.1.4.1.4756.20.170.20.1.79Columnf1000EDSFx2DDTempread-onlycurrentdevice card fiber port 2 D/D information: Temperature in degree C
1.3.6.1.4.1.4756.20.170.20.1.80Columnf1000EDSFx2DDPWRMarginread-onlycurrentdevice card fiber port 2 D/D information: Power margin
1.3.6.1.4.1.4756.20.170.20.1.81Columnf1000EDSFx1RMONInread-onlycurrentdevice card port 1 RMON IN counter.
1.3.6.1.4.1.4756.20.170.20.1.82Columnf1000EDSFx1RMONOutread-onlycurrentdevice card port 1 RMON OUT counter.
1.3.6.1.4.1.4756.20.170.20.1.83Columnf1000EDSFx2RMONInread-onlycurrentdevice card port 2 RMON IN counter.
1.3.6.1.4.1.4756.20.170.20.1.84Columnf1000EDSFx2RMONOutread-onlycurrentdevice card port 2 RMON OUT counter.
1.3.6.1.4.1.4756.20.170.20.1.85Columnf1000EDSUtp1RMONInread-onlycurrentdevice card port 3 RMON IN counter.
1.3.6.1.4.1.4756.20.170.20.1.86Columnf1000EDSUtp1RMONOutread-onlycurrentdevice card port 3 RMON OUT counter.
1.3.6.1.4.1.4756.20.170.20.1.87Columnf1000EDSUtp2RMONInread-onlycurrentdevice card port 4 RMON IN counter.
1.3.6.1.4.1.4756.20.170.20.1.88Columnf1000EDSUtp2RMONOutread-onlycurrentdevice card port 4 RMON OUT counter.
1.3.6.1.4.1.4756.20.170.20.1.89Columnf1000EDSSetDefaultread-writecurrentdevice card set to default 0:OFF 1:Action
1.3.6.1.4.1.4756.20.180Nodef100ISLocalCards
1.3.6.1.4.1.4756.20.180.20Tablef100ISLocalTablenot-accessiblecurrentA list of local FRM220-10/100IS-2 card entries. The number of entries is f100IS-No-L.
1.3.6.1.4.1.4756.20.180.20.1Rowf100ISLocalEntrynot-accessiblecurrentAn entry containing management information applicable to a particular local FRM220-10/100IS-2 card.
1.3.6.1.4.1.4756.20.180.20.1.1Columnf100ISChassisIndexLocalread-onlycurrentA unique value for each local card. It is the chassis location number.
1.3.6.1.4.1.4756.20.180.20.1.2Columnf100ISSlotIndexLocalread-onlycurrentA unique value for each local card. It is the slot location number.
1.3.6.1.4.1.4756.20.180.20.1.3Columnf100ISCardHWVerLocalread-onlycurrentLocal FRM220-10/100I card hardware version x.xxx
1.3.6.1.4.1.4756.20.180.20.1.4Columnf100ISCardFWVerLocalread-onlycurrentLocal FRM220-10/100I card firmware version x.xxx
1.3.6.1.4.1.4756.20.180.20.1.5Columnf100ISCardCPLDVerLocalread-onlycurrentLocal FRM220-10/100I card CPLD version x.xxx
1.3.6.1.4.1.4756.20.180.20.1.6Columnf100ISCardFPGAVerLocalread-onlycurrentLocal FRM220-10/100I card FPGA version x.xxx
1.3.6.1.4.1.4756.20.180.20.1.7Columnf100ISFx1PortActiveLocalread-writecurrentLocal FRM220-10/100IS-2 card FX1 active: 0:Inactive 1:Active
1.3.6.1.4.1.4756.20.180.20.1.8Columnf100ISFx2PortActiveLocalread-writecurrentLocal FRM220-10/100IS-2 card FX2 active: 0:Inactive 1:Active
1.3.6.1.4.1.4756.20.180.20.1.9Columnf100ISFx1InBandManagLocalread-writecurrentLocal FRM220-10/100IS-2 card Fx1 manages remote: 0:Disable 1:Enable
1.3.6.1.4.1.4756.20.180.20.1.10Columnf100ISFx2InBandManagLocalread-writecurrentLocal FRM220-10/100IS-2 card Fx2 manages remote: 0:Disable 1:Enable
1.3.6.1.4.1.4756.20.180.20.1.11Columnf100ISUtp3LinkLocalread-onlycurrentLocal FRM220-10/100IS-2 card UTP3 link status: 0:Down 1:Up
1.3.6.1.4.1.4756.20.180.20.1.12Columnf100ISUtp4LinkLocalread-onlycurrentLocal FRM220-10/100IS-2 card UTP4 link status: 0:Down 1:Up
1.3.6.1.4.1.4756.20.180.20.1.13Columnf100ISUtp3RxActLocalread-onlycurrentLocal FRM220-10/100IS-2 card UTP3 receive active status: 0:Off 1:On
1.3.6.1.4.1.4756.20.180.20.1.14Columnf100ISUtp4RxActLocalread-onlycurrentLocal FRM220-10/100IS-2 card UTP4 receive active status: 0:Off 1:On
1.3.6.1.4.1.4756.20.180.20.1.15Columnf100ISUtp3NegoLocalread-writecurrentLocal FRM220-10/100IS-2 card UTP3 negotiation status: 0:Manual 1:Auto
1.3.6.1.4.1.4756.20.180.20.1.16Columnf100ISUtp4NegoLocalread-writecurrentLocal FRM220-10/100IS-2 card UTP4 negotiation status: 0:Manual 1:Auto
1.3.6.1.4.1.4756.20.180.20.1.17Columnf100ISUtp3SpeedLocalread-writecurrentLocal FRM220-10/100IS-2 card UTP3 speed: 0:10MHz 1:100MHz
1.3.6.1.4.1.4756.20.180.20.1.18Columnf100ISUtp4SpeedLocalread-writecurrentLocal FRM220-10/100IS-2 card UTP4 speed: 0:10MHz 1:100MHz
1.3.6.1.4.1.4756.20.180.20.1.19Columnf100ISUtp3DuplexLocalread-writecurrentLocal FRM220-10/100IS-2 card UTP3 duplex: 0:Half duplex mode 1:Full duplex mode
1.3.6.1.4.1.4756.20.180.20.1.20Columnf100ISUtp4DuplexLocalread-writecurrentLocal FRM220-10/100IS-2 card UTP4 duplex: 0:Half duplex mode 1:Full duplex mode
1.3.6.1.4.1.4756.20.180.20.1.21Columnf100ISUtp3RxByteLocalread-onlycurrentLocal FRM220-10/100IS-2 card UTP3-in octet counter
1.3.6.1.4.1.4756.20.180.20.1.22Columnf100ISUtp4RxByteLocalread-onlycurrentLocal FRM220-10/100IS-2 card UTP4-in octet counter
1.3.6.1.4.1.4756.20.180.20.1.23Columnf100ISUtp3TxByteLocalread-onlycurrentLocal FRM220-10/100IS-2 card UTP3-out octet counter
1.3.6.1.4.1.4756.20.180.20.1.24Columnf100ISUtp4TxByteLocalread-onlycurrentLocal FRM220-10/100IS-2 card UTP4-out octet counter
1.3.6.1.4.1.4756.20.180.20.1.25Columnf100ISUtp3FnlRxByteLocalread-onlycurrentLocal FRM220-10/100IS-2 card UTP3-in final octets
1.3.6.1.4.1.4756.20.180.20.1.26Columnf100ISUtp4FnlRxByteLocalread-onlycurrentLocal FRM220-10/100IS-2 card UTP4-in final octets
1.3.6.1.4.1.4756.20.180.20.1.27Columnf100ISUtp3FnlTxByteLocalread-onlycurrentLocal FRM220-10/100IS-2 card UTP3-out final octets
1.3.6.1.4.1.4756.20.180.20.1.28Columnf100ISUtp4FnlTxByteLocalread-onlycurrentLocal FRM220-10/100IS-2 card UTP4-out final octets
1.3.6.1.4.1.4756.20.180.20.1.29Columnf100ISUtp3SpeedStatusLocalread-onlycurrentLocal FRM220-10/100IS-2 Utp3 Speed Status: 0:10MHz 1:100MHz
1.3.6.1.4.1.4756.20.180.20.1.30Columnf100ISUtp4SpeedStatusLocalread-onlycurrentLocal FRM220-10/100IS-2 Utp4 Speed Status: 0:10MHz 1:100MHz
1.3.6.1.4.1.4756.20.180.20.1.31Columnf100ISUtp3DuplexStatusLocalread-onlycurrentLocal FRM220-10/100IS-2 Utp3 Duplex Status: 0:Half 1:Full
1.3.6.1.4.1.4756.20.180.20.1.32Columnf100ISUtp4DuplexStatusLocalread-onlycurrentLocal FRM220-10/100IS-2 Utp4 Duplex Status: 0:Half 1:Full
1.3.6.1.4.1.4756.20.180.20.1.33Columnf100ISFx1LinkLocalread-onlycurrentLocal FRM220-10/100IS-2 card fiber1 link status: 0:Down 1:Up
1.3.6.1.4.1.4756.20.180.20.1.34Columnf100ISFx2LinkLocalread-onlycurrentLocal FRM220-10/100IS-2 card fiber2 link status: 0:Down 1:Up
1.3.6.1.4.1.4756.20.180.20.1.35Columnf100ISFx1RxActLocalread-onlycurrentLocal FRM220-10/100IS-2 card fiber1 receiver active status: 0:Off 1:On
1.3.6.1.4.1.4756.20.180.20.1.36Columnf100ISFx2RxActLocalread-onlycurrentLocal FRM220-10/100IS-2 card fiber2 receiver active status: 0:Off 1:On
1.3.6.1.4.1.4756.20.180.20.1.37Columnf100ISFx1FEFLocalread-onlycurrentLocal FRM220-10/100IS-2 card fiber1 detected Far End Fault: 0:Off 1:Detected
1.3.6.1.4.1.4756.20.180.20.1.38Columnf100ISFx2FEFLocalread-onlycurrentLocal FRM220-10/100IS-2 card fiber2 detected Far End Fault: 0:Off 1:Detected
1.3.6.1.4.1.4756.20.180.20.1.39Columnf100ISFx1LBTestLocalread-writecurrentForce remote FRM220-10/100IS-2 card to do fiber1 LoopBack testing: 0:Off 1:Action
1.3.6.1.4.1.4756.20.180.20.1.40Columnf100ISFx2LBTestLocalread-writecurrentForce remote FRM220-10/100IS-2 card to do fiber2 LoopBack testing: 0:Off 1:Action
1.3.6.1.4.1.4756.20.180.20.1.41Columnf100ISFx1LBStatusLocalread-onlycurrentLocal FRM220-10/100IS-2 card fiber1 LoopBack testing status: 0:Off 1:Ok 2:Fail
1.3.6.1.4.1.4756.20.180.20.1.42Columnf100ISFx2LBStatusLocalread-onlycurrentLocal FRM220-10/100IS-2 card fiber2 LoopBack testing status: 0:Off 1:Ok 2:Fail
1.3.6.1.4.1.4756.20.180.20.1.43Columnf100ISFx1RemoPWRAbLocalread-onlycurrentLocal FRM220-10/100IS-2 card fiber1 Remote Power status: 0:Abnormal 1:OK
1.3.6.1.4.1.4756.20.180.20.1.44Columnf100ISFx2RemoPWRAbLocalread-onlycurrentLocal FRM220-10/100IS-2 card fiber2 Remote Power status: 0:Abnormal 1:OK
1.3.6.1.4.1.4756.20.180.20.1.45Columnf100ISFx1IrlModeLocalread-writecurrentLocal FRM220-10/100IS-2 card Fx1 Ingress Rate Limit mode: 0:No limit 1:n x 32K 2:n x 512K
1.3.6.1.4.1.4756.20.180.20.1.46Columnf100ISFx2IrlModeLocalread-writecurrentLocal FRM220-10/100IS-2 card Fx2 Ingress Rate Limit mode: 0:No limit 1:n x 32K 2:n x 512K
1.3.6.1.4.1.4756.20.180.20.1.47Columnf100ISFx1IrlMultLocalread-writecurrentLocal FRM220-10/100IS-2 card Fx1 Ingress Rate Limit multiple: When the irlMode-L is n x 32K mode, the Fx1 irlMult-L should be the value between 0 to 255; When …
1.3.6.1.4.1.4756.20.180.20.1.48Columnf100ISFx2IrlMultLocalread-writecurrentLocal FRM220-10/100IS-2 card Fx2 Ingress Rate Limit multiple: When the irlMode-L is n x 32K mode, the Fx2 irlMult-L should be the value between 0 to 255; When …
1.3.6.1.4.1.4756.20.180.20.1.49Columnf100ISFx1ErlModeLocalread-writecurrentLocal FRM220-10/100IS-2 card Fx1 Egress Rate Limit mode: 0:No limit 1:n x 32K 2:n x 512K
1.3.6.1.4.1.4756.20.180.20.1.50Columnf100ISFx2ErlModeLocalread-writecurrentLocal FRM220-10/100IS-2 card Fx2 Egress Rate Limit mode: 0:No limit 1:n x 32K 2:n x 512K
1.3.6.1.4.1.4756.20.180.20.1.51Columnf100ISFx1ErlMultLocalread-writecurrentLocal FRM220-10/100IS-2 card Fx1 Egress Rate Limit multiple: When the erlMode-L is n x 32K mode, the Fx1 erlMult-L should be the value between 0 to 255; When t…
1.3.6.1.4.1.4756.20.180.20.1.52Columnf100ISFx2ErlMultLocalread-writecurrentLocal FRM220-10/100IS-2 card Fx2 Egress Rate Limit multiple: When the erlMode-L is n x 32K mode, the Fx2 erlMult-L should be the value between 0 to 255; When t…
1.3.6.1.4.1.4756.20.180.20.1.53Columnf100ISFx1RxByteLocalread-onlycurrentLocal FRM220-10/100IS-2 card FX1-in octet counter
1.3.6.1.4.1.4756.20.180.20.1.54Columnf100ISFx2RxByteLocalread-onlycurrentLocal FRM220-10/100IS-2 card FX2-in octet counter
1.3.6.1.4.1.4756.20.180.20.1.55Columnf100ISFx1TxByteLocalread-onlycurrentLocal FRM220-10/100IS-2 card FX1-out octet counter
1.3.6.1.4.1.4756.20.180.20.1.56Columnf100ISFx2TxByteLocalread-onlycurrentLocal FRM220-10/100IS-2 card FX2-out octet counter
1.3.6.1.4.1.4756.20.180.20.1.57Columnf100ISFx1FnlRxByteLocalread-onlycurrentLocal FRM220-10/100IS-2 card FX1-in final octets
1.3.6.1.4.1.4756.20.180.20.1.58Columnf100ISFx2FnlRxByteLocalread-onlycurrentLocal FRM220-10/100IS-2 card FX2-in final octets
1.3.6.1.4.1.4756.20.180.20.1.59Columnf100ISFx1FnlTxByteLocalread-onlycurrentLocal FRM220-10/100IS-2 card FX1-out final octets
1.3.6.1.4.1.4756.20.180.20.1.60Columnf100ISFx2FnlTxByteLocalread-onlycurrentLocal FRM220-10/100IS-2 card FX2-out final octets
1.3.6.1.4.1.4756.20.180.20.1.61Columnf100ISPortResetLocalread-writecurrentForce local FRM220-10/100IS-2 card to Fx1 reset mode: 0:Off 1:Action
1.3.6.1.4.1.4756.20.180.20.1.62Columnf100ISFx1OpModeLocalread-writecurrentLocal FRM220-10/100IS-2 card Fx1 operation mode: 0:Switch mode 1:Converter mode
1.3.6.1.4.1.4756.20.180.20.1.63Columnf100ISFx2OpModeLocalread-writecurrentLocal FRM220-10/100IS-2 card Fx2 operation mode: 0:Switch mode 1:Converter mode
1.3.6.1.4.1.4756.20.180.20.1.64Columnf100ISFx1LfpModeLocalread-writecurrentLocal FRM220-10/100IS-2 card Fx1 Link Fault Pass-through mode: 0:Disable 1:Enable
1.3.6.1.4.1.4756.20.180.20.1.65Columnf100ISFx2LfpModeLocalread-writecurrentLocal FRM220-10/100IS-2 card Fx2 Link Fault Pass-through mode: 0:Disable 1:Enable
1.3.6.1.4.1.4756.20.180.20.1.66Columnf100ISFx1AlsModeLocalread-writecurrentLocal FRM220-10/100IS-2 card Fx1 Auto Laser Shutdown mode: 0:Disable 1:Enable
1.3.6.1.4.1.4756.20.180.20.1.67Columnf100ISFx2AlsModeLocalread-writecurrentLocal FRM220-10/100IS-2 card Fx2 Auto Laser Shutdown mode: 0:Disable 1:Enable
1.3.6.1.4.1.4756.20.180.20.1.68Columnf100ISFx1SendFHRLocalread-writecurrentLocal FRM220-10/100IS-2 card Fx1 send Fiber Hardware Reset to remote: 0:No action 1:Action
1.3.6.1.4.1.4756.20.180.20.1.69Columnf100ISFx2SendFHRLocalread-writecurrentLocal FRM220-10/100IS-2 card Fx2 send Fiber Hardware Reset to remote: 0:No action 1:Action
1.3.6.1.4.1.4756.20.180.20.1.70Columnf100ISFx1DDLocalread-onlycurrentLocal FRM220-10/100IS-2 card fiber1 Digital Diagnostic function: 0:No 1:Yes
1.3.6.1.4.1.4756.20.180.20.1.71Columnf100ISFx2DDLocalread-onlycurrentLocal FRM220-10/100IS-2 card fiber2 Digital Diagnostic function: 0:No 1:Yes
1.3.6.1.4.1.4756.20.180.20.1.72Columnf100ISFx1DDVendorLocalread-onlycurrentLocal FRM220-10/100IS-2 card fiber1 D/D information: Vendor name
1.3.6.1.4.1.4756.20.180.20.1.73Columnf100ISFx2DDVendorLocalread-onlycurrentLocal FRM220-10/100IS-2 card fiber2 D/D information: Vendor name
1.3.6.1.4.1.4756.20.180.20.1.74Columnf100ISFx1DDPartNoLocalread-onlycurrentLocal FRM220-10/100IS-2 card fiber1 D/D information: Vendor part number
1.3.6.1.4.1.4756.20.180.20.1.75Columnf100ISFx2DDPartNoLocalread-onlycurrentLocal FRM220-10/100IS-2 card fiber2 D/D information: Vendor part number
1.3.6.1.4.1.4756.20.180.20.1.76Columnf100ISFx1DDFiberTypeLocalread-onlycurrentLocal FRM220-10/100IS-2 card fiber1 D/D information: Fiber Type
1.3.6.1.4.1.4756.20.180.20.1.77Columnf100ISFx2DDFiberTypeLocalread-onlycurrentLocal FRM220-10/100IS-2 card fiber2 D/D information: Fiber Type
1.3.6.1.4.1.4756.20.180.20.1.78Columnf100ISFx1DDWaveLenLocalread-onlycurrentLocal FRM220-10/100IS-2 card fiber1 D/D information: Wave length
1.3.6.1.4.1.4756.20.180.20.1.79Columnf100ISFx2DDWaveLenLocalread-onlycurrentLocal FRM220-10/100IS-2 card fiber2 D/D information: Wave length
1.3.6.1.4.1.4756.20.180.20.1.80Columnf100ISFx1DDWaveLen2Localread-onlycurrentLocal FRM220-10/100IS-2 card fiber1 D/D information: Wave length 2
1.3.6.1.4.1.4756.20.180.20.1.81Columnf100ISFx2DDWaveLen2Localread-onlycurrentLocal FRM220-10/100IS-2 card fiber2 D/D information: Wave length 2
1.3.6.1.4.1.4756.20.180.20.1.82Columnf100ISFx1DDLinkLenLocalread-onlycurrentLocal FRM220-10/100IS-2 card fiber1 D/D information: Link length
1.3.6.1.4.1.4756.20.180.20.1.83Columnf100ISFx2DDLinkLenLocalread-onlycurrentLocal FRM220-10/100IS-2 card fiber2 D/D information: Link length
1.3.6.1.4.1.4756.20.180.20.1.84Columnf100ISFx1DDLenUnitLocalread-onlycurrentLocal FRM220-10/100IS-2 card fiber1 D/D information: Length Unit
1.3.6.1.4.1.4756.20.180.20.1.85Columnf100ISFx2DDLenUnitLocalread-onlycurrentLocal FRM220-10/100IS-2 card fiber2 D/D information: Length Unit
1.3.6.1.4.1.4756.20.180.20.1.86Columnf100ISFx1DDStatusLocalread-onlycurrentLocal FRM220-10/100IS-2 card fiber1 D/D information: Status Support
1.3.6.1.4.1.4756.20.180.20.1.87Columnf100ISFx2DDStatusLocalread-onlycurrentLocal FRM220-10/100IS-2 card fiber2 D/D information: Status Support
1.3.6.1.4.1.4756.20.180.20.1.88Columnf100ISFx1DDRxSensLocalread-onlycurrentLocal FRM220-10/100IS-2 card fiber1 D/D information: Rx Sensitivity
1.3.6.1.4.1.4756.20.180.20.1.89Columnf100ISFx2DDRxSensLocalread-onlycurrentLocal FRM220-10/100IS-2 card fiber2 D/D information: Rx Sensitivity
1.3.6.1.4.1.4756.20.180.20.1.90Columnf100ISFx1DDTxPWRLocalread-onlycurrentLocal FRM220-10/100IS-2 card fiber1 D/D information: Tx power
1.3.6.1.4.1.4756.20.180.20.1.91Columnf100ISFx2DDTxPWRLocalread-onlycurrentLocal FRM220-10/100IS-2 card fiber2 D/D information: Tx power
1.3.6.1.4.1.4756.20.180.20.1.92Columnf100ISFx1DDRxPWRLocalread-onlycurrentLocal FRM220-10/100IS-2 card fiber1 D/D information: Rx power
1.3.6.1.4.1.4756.20.180.20.1.93Columnf100ISFx2DDRxPWRLocalread-onlycurrentLocal FRM220-10/100IS-2 card fiber2 D/D information: Rx power
1.3.6.1.4.1.4756.20.180.20.1.94Columnf100ISFx1DDTempLocalread-onlycurrentLocal FRM220-10/100IS-2 card fiber1 D/D information: Temperature in degree C
1.3.6.1.4.1.4756.20.180.20.1.95Columnf100ISFx2DDTempLocalread-onlycurrentLocal FRM220-10/100IS-2 card fiber2 D/D information: Temperature in degree C
1.3.6.1.4.1.4756.20.180.20.1.96Columnf100ISFx1DDPWRMarginLocalread-onlycurrentLocal FRM220-10/100IS-2 card fiber1 D/D information: Power margin
1.3.6.1.4.1.4756.20.180.20.1.97Columnf100ISFx2DDPWRMarginLocalread-onlycurrentLocal FRM220-10/100IS-2 card fiber2 D/D information: Power margin
1.3.6.1.4.1.4756.20.180.20.1.98Columnf100ISFx1DDPWRLossLocalread-onlycurrentLocal FRM220-10/100IS-2 card fiber1 D/D information: Power loss
1.3.6.1.4.1.4756.20.180.20.1.99Columnf100ISFx2DDPWRLossLocalread-onlycurrentLocal FRM220-10/100IS-2 card fiber2 D/D information: Power loss
1.3.6.1.4.1.4756.20.180.20.1.100Columnf100ISInfoR1SN1Localread-onlycurrentLocal FRM220-10/100IS-2 card INFORemoteOM S/N 1 information
1.3.6.1.4.1.4756.20.180.20.1.101Columnf100ISInfoR1SN2Localread-onlycurrentLocal FRM220-10/100IS-2 card INFORemoteOM S/N 2 information
1.3.6.1.4.1.4756.20.181Nodef100ISRemoteACards
1.3.6.1.4.1.4756.20.181.20Tablef100ISRemoteATablenot-accessiblecurrentA list of local FRM220-10/100IS-2 card entries. The number of entries is f100IS-No-L.
1.3.6.1.4.1.4756.20.181.20.1Rowf100ISRemoteAEntrynot-accessiblecurrentAn entry containing management information applicable to a particular local FRM220-10/100IS-2 card.
1.3.6.1.4.1.4756.20.181.20.1.1Columnf100ISChassisIndexRemoteAread-onlycurrentA unique value for each local card. It is the chassis location number.
1.3.6.1.4.1.4756.20.181.20.1.2Columnf100ISSlotIndexRemoteAread-onlycurrentA unique value for each local card. It is the slot location number.
1.3.6.1.4.1.4756.20.181.20.1.3Columnf100ISCardHWVerRemoteAread-onlycurrentRemoteA FRM220-10/100I card hardware version x.xxx
1.3.6.1.4.1.4756.20.181.20.1.4Columnf100ISCardFWVerRemoteAread-onlycurrentRemoteA FRM220-10/100I card firmware version x.xxx
1.3.6.1.4.1.4756.20.181.20.1.5Columnf100ISCardCPLDVerRemoteAread-onlycurrentRemoteA FRM220-10/100I card CPLD version x.xxx
1.3.6.1.4.1.4756.20.181.20.1.6Columnf100ISCardFPGAVerRemoteAread-onlycurrentRemoteA FRM220-10/100I card FPGA version x.xxx
1.3.6.1.4.1.4756.20.181.20.1.7Columnf100ISPortActiveRemoteAread-onlycurrentRemoteA FRM220-10/100IS-2 card FX1 active: 0:Inactive 1:Active
1.3.6.1.4.1.4756.20.181.20.1.8Columnf100ISInBandManagRemoteAread-onlycurrentRemoteA FRM220-10/100IS-2 card manages remote: 0:Disable 1:Enable
1.3.6.1.4.1.4756.20.181.20.1.9Columnf100ISUtpLinkRemoteAread-onlycurrentRemoteA FRM220-10/100IS-2 card UTP3 link status: 0:Down 1:Up
1.3.6.1.4.1.4756.20.181.20.1.10Columnf100ISUtpRxActRemoteAread-onlycurrentRemoteA FRM220-10/100IS-2 card UTP3 receive active status: 0:Off 1:On
1.3.6.1.4.1.4756.20.181.20.1.11Columnf100ISUtpNegoRemoteAread-writecurrentRemoteA FRM220-10/100IS-2 card UTP3 negotiation status: 0:Manual 1:Auto
1.3.6.1.4.1.4756.20.181.20.1.12Columnf100ISUtpSpeedRemoteAread-writecurrentRemoteA FRM220-10/100IS-2 card UTP3 speed Setting: 0:10MHz 1:100MHz
1.3.6.1.4.1.4756.20.181.20.1.13Columnf100ISUtpDuplexRemoteAread-writecurrentRemoteA FRM220-10/100IS-2 card UTP3 duplex Setting: 0:Half duplex mode 1:Full duplex mode
1.3.6.1.4.1.4756.20.181.20.1.14Columnf100ISUtpSpeedStatusRemoteAread-onlycurrentRemoteA FRM220-10/100IS-2 card UTP3 speed Status: 0:10MHz 1:100MHz
1.3.6.1.4.1.4756.20.181.20.1.15Columnf100ISUtpDuplexStatusRemoteAread-onlycurrentRemoteA FRM220-10/100IS-2 card UTP3 duplex Status: 0:Half duplex mode 1:Full duplex mode
1.3.6.1.4.1.4756.20.181.20.1.16Columnf100ISUtpRxByteRemoteAread-onlycurrentRemoteA FRM220-10/100IS-2 card UTP3-in octet counter
1.3.6.1.4.1.4756.20.181.20.1.17Columnf100ISUtpTxByteRemoteAread-onlycurrentRemoteA FRM220-10/100IS-2 card UTP3-out octet counter
1.3.6.1.4.1.4756.20.181.20.1.18Columnf100ISUtpFnlRxByteRemoteAread-onlycurrentRemoteA FRM220-10/100IS-2 card UTP3-in final octets
1.3.6.1.4.1.4756.20.181.20.1.19Columnf100ISUtpFnlTxByteRemoteAread-onlycurrentRemoteA FRM220-10/100IS-2 card UTP3-out final octets
1.3.6.1.4.1.4756.20.181.20.1.20Columnf100ISFxLinkRemoteAread-onlycurrentRemoteA FRM220-10/100IS-2 card fiber1 link status: 0:Down 1:Up
1.3.6.1.4.1.4756.20.181.20.1.21Columnf100ISFxRxActRemoteAread-onlycurrentRemoteA FRM220-10/100IS-2 card fiber1 receiver active status: 0:Off 1:On
1.3.6.1.4.1.4756.20.181.20.1.22Columnf100ISFxFEFRemoteAread-onlycurrentRemoteA FRM220-10/100IS-2 card fiber1 detected Far End Fault: 0:Off 1:Detected
1.3.6.1.4.1.4756.20.181.20.1.23Columnf100ISFxLBTestRemoteAread-writecurrentForce remote FRM220-10/100IS-2 card to do fiber1 LoopBack testing: 0:Off 1:Action
1.3.6.1.4.1.4756.20.181.20.1.24Columnf100ISFxLBStatusRemoteAread-onlycurrentRemoteA FRM220-10/100IS-2 card fiber1 LoopBack testing status: 0:Off 1:Ok 2:Fail
1.3.6.1.4.1.4756.20.181.20.1.25Columnf100ISRemoPWRAbRemoteAread-onlycurrentRemoteA FRM220-10/100IS-2 card fiber1 RemoteA Power status: 0:Abnormal 1:OK
1.3.6.1.4.1.4756.20.181.20.1.26Columnf100ISIrlModeRemoteAread-writecurrentRemoteA FRM220-10/100IS-2 card Ingress Rate Limit mode: 0:No limit 1:n x 32K 2:n x 512K
1.3.6.1.4.1.4756.20.181.20.1.27Columnf100ISIrlMultRemoteAread-writecurrentRemoteA FRM220-10/100IS-2 card Ingress Rate Limit multiple: When the irlMode-L is n x 32K mode, the irlMult-L should be the value between 0 to 255; When the ir…
1.3.6.1.4.1.4756.20.181.20.1.28Columnf100ISErlModeRemoteAread-writecurrentRemoteA FRM220-10/100IS-2 card Egress Rate Limit mode: 0:No limit 1:n x 32K 2:n x 512K
1.3.6.1.4.1.4756.20.181.20.1.29Columnf100ISErlMultRemoteAread-writecurrentRemoteA FRM220-10/100IS-2 card Egress Rate Limit multiple: When the erlMode-L is n x 32K mode, the erlMult-L should be the value between 0 to 255; When the erl…
1.3.6.1.4.1.4756.20.181.20.1.30Columnf100ISRxByteRemoteAread-onlycurrentRemoteA FRM220-10/100IS-2 card FX1-in octet counter
1.3.6.1.4.1.4756.20.181.20.1.31Columnf100ISTxByteRemoteAread-onlycurrentRemoteA FRM220-10/100IS-2 card FX1-out octet counter
1.3.6.1.4.1.4756.20.181.20.1.32Columnf100ISFnlRxByteRemoteAread-onlycurrentRemoteA FRM220-10/100IS-2 card FX1-in final octets
1.3.6.1.4.1.4756.20.181.20.1.33Columnf100ISFnlTxByteRemoteAread-onlycurrentRemoteA FRM220-10/100IS-2 card FX1-out final octets
1.3.6.1.4.1.4756.20.181.20.1.34Columnf100ISPortResetRemoteAread-writecurrentForce local FRM220-10/100IS-2 card to reset mode: 0:Off 1:Action
1.3.6.1.4.1.4756.20.181.20.1.35Columnf100ISOpModeRemoteAread-writecurrentRemoteA FRM220-10/100IS-2 card operation mode: 0:Switch mode 1:Converter mode
1.3.6.1.4.1.4756.20.181.20.1.36Columnf100ISLfpModeRemoteAread-writecurrentRemoteA FRM220-10/100IS-2 card Link Fault Pass-through mode: 0:Disable 1:Enable
1.3.6.1.4.1.4756.20.181.20.1.37Columnf100ISAlsModeRemoteAread-writecurrentRemoteA FRM220-10/100IS-2 card Auto Laser Shutdown mode: 0:Disable 1:Enable
1.3.6.1.4.1.4756.20.181.20.1.38Columnf100ISFhrModeRemoteAread-writecurrentRemoteA FRM220-10/100IS-2 card accept fiber hardware reset mode: 0:Disable 1:Enable
1.3.6.1.4.1.4756.20.181.20.1.39Columnf100ISDDRemoteAread-onlycurrentRemoteA FRM220-10/100IS-2 card fiber1 Digital Diagnostic function: 0:No 1:Yes
1.3.6.1.4.1.4756.20.181.20.1.40Columnf100ISDDVendorRemoteAread-onlycurrentRemoteA FRM220-10/100IS-2 card fiber1 D/D information: Vendor name
1.3.6.1.4.1.4756.20.181.20.1.41Columnf100ISDDPartNoRemoteAread-onlycurrentRemoteA FRM220-10/100IS-2 card fiber1 D/D information: Vendor part number
1.3.6.1.4.1.4756.20.181.20.1.42Columnf100ISDDFiberTypeRemoteAread-onlycurrentRemoteA FRM220-10/100IS-2 card fiber1 D/D information: Fiber Type
1.3.6.1.4.1.4756.20.181.20.1.43Columnf100ISDDWaveLenRemoteAread-onlycurrentRemoteA FRM220-10/100IS-2 card fiber1 D/D information: Wave length
1.3.6.1.4.1.4756.20.181.20.1.44Columnf100ISDDWaveLen2RemoteAread-onlycurrentRemoteA FRM220-10/100IS-2 card fiber1 D/D information: Wave length 2
1.3.6.1.4.1.4756.20.181.20.1.45Columnf100ISDDLinkLenRemoteAread-onlycurrentRemoteA FRM220-10/100IS-2 card fiber1 D/D information: Link length
1.3.6.1.4.1.4756.20.181.20.1.46Columnf100ISDDLenUnitRemoteAread-onlycurrentRemoteA FRM220-10/100IS-2 card fiber1 D/D information: Length Unit
1.3.6.1.4.1.4756.20.181.20.1.47Columnf100ISDDStatusRemoteAread-onlycurrentRemoteA FRM220-10/100IS-2 card fiber1 D/D information: Status Support
1.3.6.1.4.1.4756.20.181.20.1.48Columnf100ISDDRxSensRemoteAread-onlycurrentRemoteA FRM220-10/100IS-2 card fiber1 D/D information: Rx Sensitivity
1.3.6.1.4.1.4756.20.181.20.1.49Columnf100ISDDTxPWRRemoteAread-onlycurrentRemoteA FRM220-10/100IS-2 card fiber1 D/D information: Tx power
1.3.6.1.4.1.4756.20.181.20.1.50Columnf100ISDDRxPWRRemoteAread-onlycurrentRemoteA FRM220-10/100IS-2 card fiber1 D/D information: Rx power
1.3.6.1.4.1.4756.20.181.20.1.51Columnf100ISDDTempRemoteAread-onlycurrentRemoteA FRM220-10/100IS-2 card fiber1 D/D information: Temperature in degree C
1.3.6.1.4.1.4756.20.181.20.1.52Columnf100ISDDPWRMarginRemoteAread-onlycurrentRemoteA FRM220-10/100IS-2 card fiber1 D/D information: Power margin
1.3.6.1.4.1.4756.20.181.20.1.53Columnf100ISDDPWRLossRemoteAread-onlycurrentRemoteA FRM220-10/100IS-2 card fiber1 D/D information: Power loss
1.3.6.1.4.1.4756.20.181.20.1.54Columnf100ISInfoR1SN1RemoteAread-onlycurrentRemoteA FRM220-10/100IS-2 card INFOROM S/N 1 information
1.3.6.1.4.1.4756.20.181.20.1.55Columnf100ISInfoR1SN2RemoteAread-onlycurrentRemoteA FRM220-10/100IS-2 card INFOROM S/N 2 information
1.3.6.1.4.1.4756.20.182Nodef100ISRemoteBCards
1.3.6.1.4.1.4756.20.182.20Tablef100ISRemoteBTablenot-accessiblecurrentA list of local FRM220-10/100IS-2 card entries. The number of entries is f100IS-No-L.
1.3.6.1.4.1.4756.20.182.20.1Rowf100ISRemoteBEntrynot-accessiblecurrentAn entry containing management information applicable to a particular local FRM220-10/100IS-2 card.
1.3.6.1.4.1.4756.20.182.20.1.1Columnf100ISChassisIndexRemoteBread-onlycurrentA unique value for each local card. It is the chassis location number.
1.3.6.1.4.1.4756.20.182.20.1.2Columnf100ISSlotIndexRemoteBread-onlycurrentA unique value for each local card. It is the slot location number.
1.3.6.1.4.1.4756.20.182.20.1.3Columnf100ISCardHWVerRemoteBread-onlycurrentRemoteB FRM220-10/100I card hardware version x.xxx
1.3.6.1.4.1.4756.20.182.20.1.4Columnf100ISCardFWVerRemoteBread-onlycurrentRemoteB FRM220-10/100I card firmware version x.xxx
1.3.6.1.4.1.4756.20.182.20.1.5Columnf100ISCardCPLDVerRemoteBread-onlycurrentRemoteB FRM220-10/100I card CPLD version x.xxx
1.3.6.1.4.1.4756.20.182.20.1.6Columnf100ISCardFPGAVerRemoteBread-onlycurrentRemoteB FRM220-10/100I card FPGA version x.xxx
1.3.6.1.4.1.4756.20.182.20.1.7Columnf100ISPortActiveRemoteBread-onlycurrentRemoteB FRM220-10/100IS-2 card FX1 active: 0:Inactive 1:Active
1.3.6.1.4.1.4756.20.182.20.1.8Columnf100ISInBandManagRemoteBread-onlycurrentRemoteB FRM220-10/100IS-2 card manages remote: 0:Disable 1:Enable
1.3.6.1.4.1.4756.20.182.20.1.9Columnf100ISUtpLinkRemoteBread-onlycurrentRemoteB FRM220-10/100IS-2 card UTP3 link status: 0:Down 1:Up
1.3.6.1.4.1.4756.20.182.20.1.10Columnf100ISUtpRxActRemoteBread-onlycurrentRemoteB FRM220-10/100IS-2 card UTP3 receive active status: 0:Off 1:On
1.3.6.1.4.1.4756.20.182.20.1.11Columnf100ISUtpNegoRemoteBread-writecurrentRemoteB FRM220-10/100IS-2 card UTP3 negotiation status: 0:Manual 1:Auto
1.3.6.1.4.1.4756.20.182.20.1.12Columnf100ISUtpSpeedRemoteBread-writecurrentRemoteB FRM220-10/100IS-2 card UTP3 speed : 0:10MHz 1:100MHz
1.3.6.1.4.1.4756.20.182.20.1.13Columnf100ISUtpDuplexRemoteBread-writecurrentRemoteB FRM220-10/100IS-2 card UTP3 duplex Setting: 0:Half duplex mode 1:Full duplex mode
1.3.6.1.4.1.4756.20.182.20.1.14Columnf100ISUtpSpeedStatusRemoteBread-onlycurrentRemoteB FRM220-10/100IS-2 card UTP3 speed Status: 0:10MHz 1:100MHz
1.3.6.1.4.1.4756.20.182.20.1.15Columnf100ISUtpDuplexStatusRemoteBread-onlycurrentRemoteB FRM220-10/100IS-2 card UTP3 duplex Status: 0:Half duplex mode 1:Full duplex mode
1.3.6.1.4.1.4756.20.182.20.1.16Columnf100ISUtpRxByteRemoteBread-onlycurrentRemoteB FRM220-10/100IS-2 card UTP3-in octet Setting
1.3.6.1.4.1.4756.20.182.20.1.17Columnf100ISUtpTxByteRemoteBread-onlycurrentRemoteB FRM220-10/100IS-2 card UTP3-out octet counter
1.3.6.1.4.1.4756.20.182.20.1.18Columnf100ISUtpFnlRxByteRemoteBread-onlycurrentRemoteB FRM220-10/100IS-2 card UTP3-in final octets
1.3.6.1.4.1.4756.20.182.20.1.19Columnf100ISUtpFnlTxByteRemoteBread-onlycurrentRemoteB FRM220-10/100IS-2 card UTP3-out final octets
1.3.6.1.4.1.4756.20.182.20.1.20Columnf100ISFxLinkRemoteBread-onlycurrentRemoteB FRM220-10/100IS-2 card fiber1 link status: 0:Down 1:Up
1.3.6.1.4.1.4756.20.182.20.1.21Columnf100ISFxRxActRemoteBread-onlycurrentRemoteB FRM220-10/100IS-2 card fiber1 receiver active status: 0:Off 1:On
1.3.6.1.4.1.4756.20.182.20.1.22Columnf100ISFxFEFRemoteBread-onlycurrentRemoteB FRM220-10/100IS-2 card fiber1 detected Far End Fault: 0:Off 1:Detected
1.3.6.1.4.1.4756.20.182.20.1.23Columnf100ISFxLBTestRemoteBread-writecurrentForce remote FRM220-10/100IS-2 card to do fiber1 LoopBack testing: 0:Off 1:Action
1.3.6.1.4.1.4756.20.182.20.1.24Columnf100ISFxLBStatusRemoteBread-onlycurrentRemoteB FRM220-10/100IS-2 card fiber1 LoopBack testing status: 0:Off 1:Ok 2:Fail
1.3.6.1.4.1.4756.20.182.20.1.25Columnf100ISRemoPWRAbRemoteBread-onlycurrentRemoteB FRM220-10/100IS-2 card fiber1 RemoteB Power status: 0:Abnormal 1:OK
1.3.6.1.4.1.4756.20.182.20.1.26Columnf100ISIrlModeRemoteBread-writecurrentRemoteB FRM220-10/100IS-2 card Ingress Rate Limit mode: 0:No limit 1:n x 32K 2:n x 512K
1.3.6.1.4.1.4756.20.182.20.1.27Columnf100ISIrlMultRemoteBread-writecurrentRemoteB FRM220-10/100IS-2 card Ingress Rate Limit multiple: When the irlMode-L is n x 32K mode, the irlMult-L should be the value between 0 to 255; When the ir…
1.3.6.1.4.1.4756.20.182.20.1.28Columnf100ISErlModeRemoteBread-writecurrentRemoteB FRM220-10/100IS-2 card Egress Rate Limit mode: 0:No limit 1:n x 32K 2:n x 512K
1.3.6.1.4.1.4756.20.182.20.1.29Columnf100ISErlMultRemoteBread-writecurrentRemoteB FRM220-10/100IS-2 card Egress Rate Limit multiple: When the erlMode-L is n x 32K mode, the erlMult-L should be the value between 0 to 255; When the erl…
1.3.6.1.4.1.4756.20.182.20.1.30Columnf100ISRxByteRemoteBread-onlycurrentRemoteB FRM220-10/100IS-2 card FX1-in octet counter
1.3.6.1.4.1.4756.20.182.20.1.31Columnf100ISTxByteRemoteBread-onlycurrentRemoteB FRM220-10/100IS-2 card FX1-out octet counter
1.3.6.1.4.1.4756.20.182.20.1.32Columnf100ISFnlRxByteRemoteBread-onlycurrentRemoteB FRM220-10/100IS-2 card FX1-in final octets
1.3.6.1.4.1.4756.20.182.20.1.33Columnf100ISFnlTxByteRemoteBread-onlycurrentRemoteB FRM220-10/100IS-2 card FX1-out final octets
1.3.6.1.4.1.4756.20.182.20.1.34Columnf100ISPortResetRemoteBread-writecurrentForce local FRM220-10/100IS-2 card to reset mode: 0:Off 1:Action
1.3.6.1.4.1.4756.20.182.20.1.35Columnf100ISOpModeRemoteBread-writecurrentRemoteB FRM220-10/100IS-2 card operation mode: 0:Switch mode 1:Converter mode
1.3.6.1.4.1.4756.20.182.20.1.36Columnf100ISLfpModeRemoteBread-writecurrentRemoteB FRM220-10/100IS-2 card Link Fault Pass-through mode: 0:Disable 1:Enable
1.3.6.1.4.1.4756.20.182.20.1.37Columnf100ISAlsModeRemoteBread-writecurrentRemoteB FRM220-10/100IS-2 card Auto Laser Shutdown mode: 0:Disable 1:Enable
1.3.6.1.4.1.4756.20.182.20.1.38Columnf100ISFhrModeRemoteBread-writecurrentRemoteB FRM220-10/100IS-2 card accept Fiber Hardware Reset mode: 0:Disable 1:Enable
1.3.6.1.4.1.4756.20.182.20.1.39Columnf100ISDDRemoteBread-onlycurrentRemoteB FRM220-10/100IS-2 card fiber1 Digital Diagnostic function: 0:No 1:Yes
1.3.6.1.4.1.4756.20.182.20.1.40Columnf100ISDDVendorRemoteBread-onlycurrentRemoteB FRM220-10/100IS-2 card fiber1 D/D information: Vendor name
1.3.6.1.4.1.4756.20.182.20.1.41Columnf100ISDDPartNoRemoteBread-onlycurrentRemoteB FRM220-10/100IS-2 card fiber1 D/D information: Vendor part number
1.3.6.1.4.1.4756.20.182.20.1.42Columnf100ISDDFiberTypeRemoteBread-onlycurrentRemoteB FRM220-10/100IS-2 card fiber1 D/D information: Fiber Type
1.3.6.1.4.1.4756.20.182.20.1.43Columnf100ISDDWaveLenRemoteBread-onlycurrentRemoteB FRM220-10/100IS-2 card fiber1 D/D information: Wave length
1.3.6.1.4.1.4756.20.182.20.1.44Columnf100ISDDWaveLen2RemoteBread-onlycurrentRemoteB FRM220-10/100IS-2 card fiber1 D/D information: Wave length 2
1.3.6.1.4.1.4756.20.182.20.1.45Columnf100ISDDLinkLenRemoteBread-onlycurrentRemoteB FRM220-10/100IS-2 card fiber1 D/D information: Link length
1.3.6.1.4.1.4756.20.182.20.1.46Columnf100ISDDLenUnitRemoteBread-onlycurrentRemoteB FRM220-10/100IS-2 card fiber1 D/D information: Length Unit
1.3.6.1.4.1.4756.20.182.20.1.47Columnf100ISDDStatusRemoteBread-onlycurrentRemoteB FRM220-10/100IS-2 card fiber1 D/D information: Status Support
1.3.6.1.4.1.4756.20.182.20.1.48Columnf100ISDDRxSensRemoteBread-onlycurrentRemoteB FRM220-10/100IS-2 card fiber1 D/D information: Rx Sensitivity
1.3.6.1.4.1.4756.20.182.20.1.49Columnf100ISDDTxPWRRemoteBread-onlycurrentRemoteB FRM220-10/100IS-2 card fiber1 D/D information: Tx power
1.3.6.1.4.1.4756.20.182.20.1.50Columnf100ISDDRxPWRRemoteBread-onlycurrentRemoteB FRM220-10/100IS-2 card fiber1 D/D information: Rx power
1.3.6.1.4.1.4756.20.182.20.1.51Columnf100ISDDTempRemoteBread-onlycurrentRemoteB FRM220-10/100IS-2 card fiber1 D/D information: Temperature in degree C
1.3.6.1.4.1.4756.20.182.20.1.52Columnf100ISDDPWRMarginRemoteBread-onlycurrentRemoteB FRM220-10/100IS-2 card fiber1 D/D information: Power margin
1.3.6.1.4.1.4756.20.182.20.1.53Columnf100ISDDPWRLossRemoteBread-onlycurrentRemoteB FRM220-10/100IS-2 card fiber1 D/D information: Power loss
1.3.6.1.4.1.4756.20.182.20.1.54Columnf100ISInfoR1SN1RemoteBread-onlycurrentRemoteB FRM220-10/100IS-2 card INFORemoteBOM S/N 1 information
1.3.6.1.4.1.4756.20.182.20.1.55Columnf100ISInfoR1SN2RemoteBread-onlycurrentRemoteB FRM220-10/100IS-2 card INFORemoteBOM S/N 2 information
1.3.6.1.4.1.4756.20.190Nodef100ASLocalCards
1.3.6.1.4.1.4756.20.190.40Tablef100ASLocalTablenot-accessiblecurrentA list of local frm220-100AS card entries. The number of entries is f100AS-NoLocal.
1.3.6.1.4.1.4756.20.190.40.1Rowf100ASLocalEntrynot-accessiblecurrentAn entry containing management information applicable to a particular local FRM-100AS card.
1.3.6.1.4.1.4756.20.190.40.1.1Columnf100ASChassisIndexLocalread-onlycurrentA unique value for each local card. It is the chassis location number.
1.3.6.1.4.1.4756.20.190.40.1.2Columnf100ASSlotIndexLocalread-onlycurrentA unique value for each local card. It is the slot location number.
1.3.6.1.4.1.4756.20.190.40.1.3Columnf100ASCardHWVerLocalread-onlycurrentLocal device card hardware version x.xxx
1.3.6.1.4.1.4756.20.190.40.1.4Columnf100ASCardFWVerLocalread-onlycurrentLocal device card firmware version x.xxx
1.3.6.1.4.1.4756.20.190.40.1.5Columnf100ASCardCPLDVerLocalread-onlycurrentLocal device card CPLD version x.xxx
1.3.6.1.4.1.4756.20.190.40.1.6Columnf100ASCardFPGAVerLocalread-onlycurrentLocal device card FPGA version x.xxx
1.3.6.1.4.1.4756.20.190.40.1.7Columnf100ASModelLocalread-onlycurrentLocal frm220 f100AS Serial Type
1.3.6.1.4.1.4756.20.190.40.1.8Columnf100ASFx1LinkLocalread-onlycurrentLocal device card fiber port 1 link status: 0:Down 1:Up
1.3.6.1.4.1.4756.20.190.40.1.9Columnf100ASFx1OAMLoopedLocalread-onlycurrentLocal device card fiber port 1 OAM looped: 0:Off 1:on
1.3.6.1.4.1.4756.20.190.40.1.10Columnf100ASFx1LBTestLocalread-writecurrentForce remote device card to do fiber port 1 LoopBack testing: 0:Off 1:Action
1.3.6.1.4.1.4756.20.190.40.1.11Columnf100ASFx1OAMRLBStatusLocalread-onlycurrentRemote device card fiber port 1 LoopBack testing status: 0:Off 1:Ok 2:Fail
1.3.6.1.4.1.4756.20.190.40.1.12Columnf100ASFx1RemoPwrAbLocalread-onlycurrentLocal device card fiber port 1 Remote Power status: 0:Abnormal 1:OK 2:None
1.3.6.1.4.1.4756.20.190.40.1.13Columnf100ASFx2LinkLocalread-onlycurrentLocal device card fiber port 2 link status: 0:Down 1:Up
1.3.6.1.4.1.4756.20.190.40.1.14Columnf100ASFx2OAMLoopedLocalread-onlycurrentLocal device card fiber port 2 OAM looped: 0:Off 1:on
1.3.6.1.4.1.4756.20.190.40.1.15Columnf100ASFx2LBTestLocalread-writecurrentForce remote device card to do fiber port 2 LoopBack testing: 0:Off 1:Action
1.3.6.1.4.1.4756.20.190.40.1.16Columnf100ASFx2OAMRLBStatusLocalread-onlycurrentRemote device card fiber port 1 LoopBack testing status: 0:Off 1:Ok 2:Fail
1.3.6.1.4.1.4756.20.190.40.1.17Columnf100ASFx2RemoPwrAbLocalread-onlycurrentLocal device card fiber port 2 Remote Power status: 0:Abnormal 1:OK 2:None
1.3.6.1.4.1.4756.20.190.40.1.18Columnf100ASUtp1LinkLocalread-onlycurrentLocal device card UTP port 3 link status: 0:Down 1:Up
1.3.6.1.4.1.4756.20.190.40.1.19Columnf100ASUtp1NegoLocalread-writecurrentLocal device card UTP port 3 negotiation status: 0:Manual 1:Auto
1.3.6.1.4.1.4756.20.190.40.1.20Columnf100ASUtp1SpeedLocalread-writecurrentLocal device card UTP port 3 speed setting: 0:10 Base-T 1:100 Base-TX
1.3.6.1.4.1.4756.20.190.40.1.21Columnf100ASUtp1DuplexLocalread-writecurrentLocal device card UTP port 3 duplex setting: 0:Half duplex mode 1:Full duplex mode
1.3.6.1.4.1.4756.20.190.40.1.22Columnf100ASUtp1SpeedStatusLocalread-onlycurrentLocal device card UTP port 3 speed status: 0:10 Base-T 1:100 Base-TX
1.3.6.1.4.1.4756.20.190.40.1.23Columnf100ASUtp1DuplexStatusLocalread-onlycurrentLocal device card UTP port 3 duplex status: 0:Half duplex mode 1:Full duplex mode
1.3.6.1.4.1.4756.20.190.40.1.24Columnf100ASUtp2LinkLocalread-onlycurrentLocal device card UTP port 4 link status: 0:Down 1:Up
1.3.6.1.4.1.4756.20.190.40.1.25Columnf100ASUtp2NegoLocalread-writecurrentLocal device card UTP port 4 negotiation status: 0:Manual 1:Auto
1.3.6.1.4.1.4756.20.190.40.1.26Columnf100ASUtp2SpeedLocalread-writecurrentLocal device card UTP port 4 speed setting: 0:10 Base-T 1:100 Base-TX
1.3.6.1.4.1.4756.20.190.40.1.27Columnf100ASUtp2DuplexLocalread-writecurrentLocal device card UTP port 4 duplex setting: 0:Half duplex mode 1:Full duplex mode
1.3.6.1.4.1.4756.20.190.40.1.28Columnf100ASUtp2SpeedStatusLocalread-onlycurrentLocal device card UTP port 4 speed status: 0:10 Base-T 1:100 Base-TX
1.3.6.1.4.1.4756.20.190.40.1.29Columnf100ASUtp2DuplexStatusLocalread-onlycurrentLocal device card UTP port 4 duplex status: 0:Half duplex mode 1:Full duplex mode
1.3.6.1.4.1.4756.20.190.40.1.30Columnf100ASFx1IrlModeLocalread-writecurrentLocal device card port 1 Rate Limit mode: 0:unlimited 1:limited
1.3.6.1.4.1.4756.20.190.40.1.31Columnf100ASFx1IrlIndexLocalread-writecurrentLocal device card port 1 Ingress Rate Limit index: Index Limit Rate 0 Unlimited 1 128K 2 256K 3 521K 4 1M 5 2M 6 4M 7 8M
1.3.6.1.4.1.4756.20.190.40.1.32Columnf100ASFx1ErlIndexLocalread-writecurrentLocal device card port 1 Egress Rate Limit index: Index Limit Rate 0 Unlimited 1 128K 2 256K 3 521K 4 1M 5 2M 6 4M 7 8M
1.3.6.1.4.1.4756.20.190.40.1.33Columnf100ASFx2IrlModeLocalread-writecurrentLocal device card port 2 Rate Limit mode: 0:unlimited 1:limited
1.3.6.1.4.1.4756.20.190.40.1.34Columnf100ASFx2IrlIndexLocalread-writecurrentLocal device card port 2 Ingress Rate Limit index: Index Limit Rate 0 Unlimited 1 128K 2 256K 3 521K 4 1M 5 2M 6 4M 7 8M
1.3.6.1.4.1.4756.20.190.40.1.35Columnf100ASFx2ErlIndexLocalread-writecurrentLocal device card port 2 Egress Rate Limit index: Index Limit Rate 0 Unlimited 1 128K 2 256K 3 521K 4 1M 5 2M 6 4M 7 8M
1.3.6.1.4.1.4756.20.190.40.1.36Columnf100ASUtp1IrlModeLocalread-writecurrentLocal device card port 3 Rate Limit mode: 0:unlimited 1:limited
1.3.6.1.4.1.4756.20.190.40.1.37Columnf100ASUtp1IrlIndexLocalread-writecurrentLocal device card port 3 Ingress Rate Limit index: Index Limit Rate 0 Unlimited 1 128K 2 256K 3 521K 4 1M 5 2M 6 4M 7 8M
1.3.6.1.4.1.4756.20.190.40.1.38Columnf100ASUtp1ErlIndexLocalread-writecurrentLocal device card port 3 Egress Rate Limit index: Index Limit Rate 0 Unlimited 1 128K 2 256K 3 521K 4 1M 5 2M 6 4M 7 8M
1.3.6.1.4.1.4756.20.190.40.1.39Columnf100ASUtp2IrlModeLocalread-writecurrentLocal device card port 4 Rate Limit mode: 0:unlimited 1:limited
1.3.6.1.4.1.4756.20.190.40.1.40Columnf100ASUtp2IrlIndexLocalread-writecurrentLocal device card port 4 Ingress Rate Limit index: Index Limit Rate 0 Unlimited 1 128K 2 256K 3 521K 4 1M 5 2M 6 4M 7 8M
1.3.6.1.4.1.4756.20.190.40.1.41Columnf100ASUtp2ErlIndexLocalread-writecurrentLocal device card port 4 Egress Rate Limit index: Index Limit Rate 0 Unlimited 1 128K 2 256K 3 521K 4 1M 5 2M 6 4M 7 8M
1.3.6.1.4.1.4756.20.190.40.1.42Columnf100ASDeviceActiveLocalread-writecurrentLocal device card active mode: (It is read-only in local device.) 0:Disable 1:Enable
1.3.6.1.4.1.4756.20.190.40.1.43Columnf100ASDeviceResetLocalread-writecurrentForce local device card to reset mode: 0:Off 1:Action
1.3.6.1.4.1.4756.20.190.40.1.44Columnf100ASFx1ActiveLocalread-writecurrentLocal device fiber port 1 active mode: 0:Disable 1:Enable
1.3.6.1.4.1.4756.20.190.40.1.45Columnf100ASFx2ActiveLocalread-writecurrentLocal device fiber port 2 active mode: 0:Disable 1:Enable
1.3.6.1.4.1.4756.20.190.40.1.46Columnf100ASUtp1ActiveLocalread-writecurrentLocal device UTP port 3 active mode: 0:Disable 1:Enable
1.3.6.1.4.1.4756.20.190.40.1.47Columnf100ASUtp2ActiveLocalread-writecurrentLocal device UTP port 4 active mode: 0:Disable 1:Enable
1.3.6.1.4.1.4756.20.190.40.1.48Columnf100ASOamChAModeLocalread-writecurrentLocal device OAM Channel A mode: 0:Disable 1:passive 2:Active
1.3.6.1.4.1.4756.20.190.40.1.49Columnf100ASOamChBModeLocalread-writecurrentLocal device OAM Channel B mode: 0:Disable 1:passive 2:Active
1.3.6.1.4.1.4756.20.190.40.1.50Columnf100ASOamMaxPDUsLocalread-writecurrentLocal device OAM max OAMPDU size: 60-1518 Octets
1.3.6.1.4.1.4756.20.190.40.1.51Columnf100ASFx1AlsLocalread-writecurrentLocal device card port 1 Auto Laser Shutdown mode: 0:Disable 1:Enable
1.3.6.1.4.1.4756.20.190.40.1.52Columnf100ASFx2AlsLocalread-writecurrentLocal device card port 2 Auto Laser Shutdown mode: 0:Disable 1:Enable
1.3.6.1.4.1.4756.20.190.40.1.53Columnf100ASPauseFrameLocalread-writecurrentLocal device card pause frame mode: 0:Disable 1:Enable
1.3.6.1.4.1.4756.20.190.40.1.54Columnf100ASSendFHRtoALocalread-writecurrentLocal device card port 1 send Fiber Hardware Reset to remote: 0:No action 1:Action
1.3.6.1.4.1.4756.20.190.40.1.55Columnf100ASSendFHRtoBLocalread-writecurrentLocal device card port 2 send Fiber Hardware Reset to remote: 0:No action 1:Action
1.3.6.1.4.1.4756.20.190.40.1.56Columnf100ASFx1LLFDepLogiLocalread-writecurrentLocal device card port 1 Link Loss Forwarding depends boolean logic: 0:and 1:or
1.3.6.1.4.1.4756.20.190.40.1.57Columnf100ASFx1LLFDepPort2Localread-writecurrentLocal device card port 1 Link Loss Forwarding depends on port 2 Fiber Rx link: 0:don't care 1:selected
1.3.6.1.4.1.4756.20.190.40.1.58Columnf100ASFx1LLFDepPort3Localread-writecurrentLocal device card port 1 Link Loss Forwarding depends on port 3 Ethernet Rx link: 0:don't care 1:selected
1.3.6.1.4.1.4756.20.190.40.1.59Columnf100ASFx1LLFDepPort4Localread-writecurrentLocal device card port 1 Link Loss Forwarding depends on port 4 Ethernet Rx link: 0:don't care 1:selected
1.3.6.1.4.1.4756.20.190.40.1.60Columnf100ASFx2LLFDepLogiLocalread-writecurrentLocal device card port 2 Link Loss Forwarding depends boolean logic: 0:and 1:or
1.3.6.1.4.1.4756.20.190.40.1.61Columnf100ASFx2LLFDepPort1Localread-writecurrentLocal device card port 2 Link Loss Forwarding depends on port 1 Fiber Rx link: 0:don't care 1:selected
1.3.6.1.4.1.4756.20.190.40.1.62Columnf100ASFx2LLFDepPort3Localread-writecurrentLocal device card port 2 Link Loss Forwarding depends on port 3 Ethernet Rx link: 0:don't care 1:selected
1.3.6.1.4.1.4756.20.190.40.1.63Columnf100ASFx2LLFDepPort4Localread-writecurrentLocal device card port 2 Link Loss Forwarding depends on port 4 Ethernet Rx link: 0:don't care 1:selected
1.3.6.1.4.1.4756.20.190.40.1.64Columnf100ASUtp1LLFDepLogiLocalread-writecurrentLocal device card port 3 Link Loss Forwarding depends boolean logic: 0:and 1:or
1.3.6.1.4.1.4756.20.190.40.1.65Columnf100ASUtp1LLFDepPort1Localread-writecurrentLocal device card port 3 Link Loss Forwarding depends on port 1 Fiber Rx link: 0:don't care 1:selected
1.3.6.1.4.1.4756.20.190.40.1.66Columnf100ASUtp1LLFDepPort2Localread-writecurrentLocal device card port 3 Link Loss Forwarding depends on port 2 Fiber Rx link: 0:don't care 1:selected
1.3.6.1.4.1.4756.20.190.40.1.67Columnf100ASUtp2LLFDepLogiLocalread-writecurrentLocal device card port 4 Link Loss Forwarding depends boolean logic: 0:and 1:or
1.3.6.1.4.1.4756.20.190.40.1.68Columnf100ASUtp2LLFDepPort1Localread-writecurrentLocal device card port 4 Link Loss Forwarding depends on port 1 Fiber Rx link: 0:don't care 1:selected
1.3.6.1.4.1.4756.20.190.40.1.69Columnf100ASUtp2LLFDepPort2Localread-writecurrentLocal device card port 4 Link Loss Forwarding depends on port 2 Fiber Rx link: 0:don't care 1:selected
1.3.6.1.4.1.4756.20.190.40.1.70Columnf100ASAdvanceFunsLocalread-writecurrentLocal device card Switch functions mode: 0:Normal 2:Port 1&2 Mirror 3:Port VLAN 1/3;2/4 4:Port 1&2 Redundancy 5:Static 802.1Q VLAN 6:Spanning Tree protocol 7:S…
1.3.6.1.4.1.4756.20.190.40.1.71Columnf100ASFx1InfoROM1Localread-onlycurrentLocal device card port 1 INFORemoteOM information 1 valid: 0:Invalid 1:Valid
1.3.6.1.4.1.4756.20.190.40.1.72Columnf100ASFx1InfoROM2Localread-onlycurrentLocal device card port 1 INFORemoteOM information 2 valid: 0:Invalid 1:Valid(replacing D/D function
1.3.6.1.4.1.4756.20.190.40.1.73Columnf100ASFx2InfoROM1Localread-onlycurrentLocal device card port 2 INFORemoteOM information 1 valid: 0:Invalid 1:Valid
1.3.6.1.4.1.4756.20.190.40.1.74Columnf100ASFx2InfoROM2Localread-onlycurrentLocal device card port 2 INFORemoteOM information 2 valid: 0:Invalid 1:Valid(replacing D/D function)
1.3.6.1.4.1.4756.20.190.40.1.75Columnf100ASFx1InfoSN1Localread-onlycurrentLocal device card port 1 INFORemoteOM S/N 1
1.3.6.1.4.1.4756.20.190.40.1.76Columnf100ASFx1InfoSN2Localread-onlycurrentLocal device card port 1 INFORemoteOM S/N 2
1.3.6.1.4.1.4756.20.190.40.1.77Columnf100ASFx2InfoSN1Localread-onlycurrentLocal device card port 2 INFORemoteOM S/N 1
1.3.6.1.4.1.4756.20.190.40.1.78Columnf100ASFx2InfoSN2Localread-onlycurrentLocal device card port 2 INFORemoteOM S/N 2
1.3.6.1.4.1.4756.20.190.40.1.79Columnf100ASFx1DDLocalread-onlycurrentLocal device card fiber port 1 Digital Diagnostic function: 0:No 1:Yes
1.3.6.1.4.1.4756.20.190.40.1.80Columnf100ASFx1DDVendorLocalread-onlycurrentLocal device card fiber port 1 D/D information: Vendor name
1.3.6.1.4.1.4756.20.190.40.1.81Columnf100ASFx1DDPartNoLocalread-onlycurrentLocal device card fiber port 1 D/D information: Vendor part number
1.3.6.1.4.1.4756.20.190.40.1.82Columnf100ASFx1DDFiberTypeLocalread-onlycurrentLocal device card fiber port 1 D/D information: Fiber Type
1.3.6.1.4.1.4756.20.190.40.1.83Columnf100ASFx1DDWaveLenLocalread-onlycurrentLocal device card fiber port 1 D/D information: Wave length
1.3.6.1.4.1.4756.20.190.40.1.84Columnf100ASFx1DDWaveLen2Localread-onlycurrentLocal device card fiber port 1 D/D information: Wave length 2
1.3.6.1.4.1.4756.20.190.40.1.85Columnf100ASFx1DDLinkLenLocalread-onlycurrentLocal device card fiber port 1 D/D information: Link length
1.3.6.1.4.1.4756.20.190.40.1.86Columnf100ASFx1DDLenUnitLocalread-onlycurrentLocal device card fiber port 1 D/D information: Length Unit
1.3.6.1.4.1.4756.20.190.40.1.87Columnf100ASFx1DDStatusLocalread-onlycurrentLocal device card fiber port 1 D/D information: Status Support
1.3.6.1.4.1.4756.20.190.40.1.88Columnf100ASFx1DDRxSensLocalread-onlycurrentLocal device card fiber port 1 D/D information: Rx Sensitivity
1.3.6.1.4.1.4756.20.190.40.1.89Columnf100ASFx1DDTxPWRLocalread-onlycurrentLocal device card fiber port 1 D/D information: Tx power
1.3.6.1.4.1.4756.20.190.40.1.90Columnf100ASFx1DDRxPWRLocalread-onlycurrentLocal device card fiber port 1 D/D information: Rx power
1.3.6.1.4.1.4756.20.190.40.1.91Columnf100ASFx1DDTempLocalread-onlycurrentLocal device card fiber port 1 D/D information: Temperature in degree C
1.3.6.1.4.1.4756.20.190.40.1.92Columnf100ASFx1DDPWRMarginLocalread-onlycurrentLocal device card fiber port 1 D/D information: Power margin
1.3.6.1.4.1.4756.20.190.40.1.93Columnf100ASFx1DDPWRLossLocalread-onlycurrentLocal device card fiber port 1 D/D information: Power loss
1.3.6.1.4.1.4756.20.190.40.1.94Columnf100ASFx2DDLocalread-onlycurrentLocal device card fiber port 2 Digital Diagnostic function: 0:No 1:Yes
1.3.6.1.4.1.4756.20.190.40.1.95Columnf100ASFx2DDVendorLocalread-onlycurrentLocal device card fiber port 2 D/D information: Vendor name
1.3.6.1.4.1.4756.20.190.40.1.96Columnf100ASFx2DDPartNoLocalread-onlycurrentLocal device card fiber port 2 D/D information: Vendor part number
1.3.6.1.4.1.4756.20.190.40.1.97Columnf100ASFx2DDFiberTypeLocalread-onlycurrentLocal device card fiber port 2 D/D information: Fiber Type
1.3.6.1.4.1.4756.20.190.40.1.98Columnf100ASFx2DDWaveLenLocalread-onlycurrentLocal device card fiber port 2 D/D information: Wave length
1.3.6.1.4.1.4756.20.190.40.1.99Columnf100ASFx2DDWaveLen2Localread-onlycurrentLocal device card fiber port 2 D/D information: Wave length 2
1.3.6.1.4.1.4756.20.190.40.1.100Columnf100ASFx2DDLinkLenLocalread-onlycurrentLocal device card fiber port 2 D/D information: Link length
1.3.6.1.4.1.4756.20.190.40.1.101Columnf100ASFx2DDLenUnitLocalread-onlycurrentLocal device card fiber port 2 D/D information: Length Unit
1.3.6.1.4.1.4756.20.190.40.1.102Columnf100ASFx2DDStatusLocalread-onlycurrentLocal device card fiber port 2 D/D information: Status Support
1.3.6.1.4.1.4756.20.190.40.1.103Columnf100ASFx2DDRxSensLocalread-onlycurrentLocal device card fiber port 2 D/D information: Rx Sensitivity
1.3.6.1.4.1.4756.20.190.40.1.104Columnf100ASFx2DDTxPWRLocalread-onlycurrentLocal device card fiber port 2 D/D information: Tx power
1.3.6.1.4.1.4756.20.190.40.1.105Columnf100ASFx2DDRxPWRLocalread-onlycurrentLocal device card fiber port 2 D/D information: Rx power
1.3.6.1.4.1.4756.20.190.40.1.106Columnf100ASFx2DDTempLocalread-onlycurrentLocal device card fiber port 2 D/D information: Temperature in degree C
1.3.6.1.4.1.4756.20.190.40.1.107Columnf100ASFx2DDPWRMarginLocalread-onlycurrentLocal device card fiber port 2 D/D information: Power margin
1.3.6.1.4.1.4756.20.190.40.1.108Columnf100ASFx2DDPWRLossLocalread-onlycurrentLocal device card fiber port 2 D/D information: Power loss
1.3.6.1.4.1.4756.20.190.40.1.109Columnf100ASClrRMONCntsLocalread-writecurrentClear local device card RMON IN/OUT counters: 0:No action 1:Action
1.3.6.1.4.1.4756.20.190.40.1.110Columnf100ASFx1RMONInLocalread-onlycurrentLocal device card port 1 RMON IN counter.
1.3.6.1.4.1.4756.20.190.40.1.111Columnf100ASFx1RMONOutLocalread-onlycurrentLocal device card port 1 RMON OUT counter.
1.3.6.1.4.1.4756.20.190.40.1.112Columnf100ASFx2RMONInLocalread-onlycurrentLocal device card port 2 RMON IN counter.
1.3.6.1.4.1.4756.20.190.40.1.113Columnf100ASFx2RMONOutLocalread-onlycurrentLocal device card port 2 RMON OUT counter.
1.3.6.1.4.1.4756.20.190.40.1.114Columnf100ASUtp1RMONInLocalread-onlycurrentLocal device card port 3 RMON IN counter.
1.3.6.1.4.1.4756.20.190.40.1.115Columnf100ASUtp1RMONOutLocalread-onlycurrentLocal device card port 3 RMON OUT counter.
1.3.6.1.4.1.4756.20.190.40.1.116Columnf100ASUtp2RMONInLocalread-onlycurrentLocal device card port 4 RMON IN counter.
1.3.6.1.4.1.4756.20.190.40.1.117Columnf100ASUtp2RMONOutLocalread-onlycurrentLocal device card port 4 RMON OUT counter.
1.3.6.1.4.1.4756.20.190.40.1.118Columnf100ASClrOAMCntsLocalread-writecurrentClear local device card OAM counters: 0:No action 1:Action
1.3.6.1.4.1.4756.20.190.40.1.119Columnf100ASOamChATxLocalread-onlycurrentLocal device OAM Channel A TX OAMPDU frame count
1.3.6.1.4.1.4756.20.190.40.1.120Columnf100ASOamChARxLocalread-onlycurrentLocal device OAM Channel A RX OAMPDU frame count
1.3.6.1.4.1.4756.20.190.40.1.121Columnf100ASOamInfoChATxLocalread-onlycurrentLocal device OAM Channel A TX Information OAMPDU frame count
1.3.6.1.4.1.4756.20.190.40.1.122Columnf100ASOamInfoChARxLocalread-onlycurrentLocal device OAM Channel A RX Information OAMPDU frame count
1.3.6.1.4.1.4756.20.190.40.1.123Columnf100ASOamEventChATxLocalread-onlycurrentLocal device OAM Channel A TX Event OAMPDU frame count
1.3.6.1.4.1.4756.20.190.40.1.124Columnf100ASOamUniEvtChARxLocalread-onlycurrentLocal device OAM Channel A RX Unique Event OAMPDU frame count
1.3.6.1.4.1.4756.20.190.40.1.125Columnf100ASOamDupEvtChARxLocalread-onlycurrentLocal device OAM Channel A RX Duplicate Event OAMPDU frame count
1.3.6.1.4.1.4756.20.190.40.1.126Columnf100ASOamLbChATxLocalread-onlycurrentLocal device OAM Channel A TX Loopback Control OAMPDU frame count
1.3.6.1.4.1.4756.20.190.40.1.127Columnf100ASOamLbChARxLocalread-onlycurrentLocal device OAM Channel A RX Loopback Control OAMPDU frame count
1.3.6.1.4.1.4756.20.190.40.1.128Columnf100ASOamVarReqChATxLocalread-onlycurrentLocal device OAM Channel A TX Variable Request OAMPDU frame count
1.3.6.1.4.1.4756.20.190.40.1.129Columnf100ASOamVarReqChARxLocalread-onlycurrentLocal device OAM Channel A RX Variable Request OAMPDU frame count
1.3.6.1.4.1.4756.20.190.40.1.130Columnf100ASOamVarRspChATxLocalread-onlycurrentLocal device OAM Channel A TX Variable Response OAMPDU frame count
1.3.6.1.4.1.4756.20.190.40.1.131Columnf100ASOamVarRspChARxLocalread-onlycurrentLocal device OAM Channel A RX Variable Response OAMPDU frame count
1.3.6.1.4.1.4756.20.190.40.1.132Columnf100ASOamOuiChATxLocalread-onlycurrentLocal device OAM Channel A TX OUI OAMPDU frame count
1.3.6.1.4.1.4756.20.190.40.1.133Columnf100ASOamOuiChARxLocalread-onlycurrentLocal device OAM Channel A RX OUI OAMPDU frame count
1.3.6.1.4.1.4756.20.190.40.1.134Columnf100ASOamUnknowChARxLocalread-onlycurrentLocal device OAM Channel A RX Unsupported OAMPDU frame count
1.3.6.1.4.1.4756.20.190.40.1.135Columnf100ASOamChBTxLocalread-onlycurrentLocal device OAM Channel B TX OAMPDU frame count
1.3.6.1.4.1.4756.20.190.40.1.136Columnf100ASOamChBRxLocalread-onlycurrentLocal device OAM Channel B RX OAMPDU frame count
1.3.6.1.4.1.4756.20.190.40.1.137Columnf100ASOamInfoChBTxLocalread-onlycurrentLocal device OAM Channel B TX Information OAMPDU frame count
1.3.6.1.4.1.4756.20.190.40.1.138Columnf100ASOamInfoChBRxLocalread-onlycurrentLocal device OAM Channel B RX Information OAMPDU frame count
1.3.6.1.4.1.4756.20.190.40.1.139Columnf100ASOamEventChBTxLocalread-onlycurrentLocal device OAM Channel B TX Event OAMPDU frame count
1.3.6.1.4.1.4756.20.190.40.1.140Columnf100ASOamUniEvtChBRxLocalread-onlycurrentLocal device OAM Channel B RX Unique Event OAMPDU frame count
1.3.6.1.4.1.4756.20.190.40.1.141Columnf100ASOamDupEvtChBRxLocalread-onlycurrentLocal device OAM Channel B RX Duplicate Event OAMPDU frame count
1.3.6.1.4.1.4756.20.190.40.1.142Columnf100ASOamLbChBTxLocalread-onlycurrentLocal device OAM Channel B TX Loopback Control OAMPDU frame count
1.3.6.1.4.1.4756.20.190.40.1.143Columnf100ASOamLbChBRxLocalread-onlycurrentLocal device OAM Channel B RX Loopback Control OAMPDU frame count
1.3.6.1.4.1.4756.20.190.40.1.144Columnf100ASOamVarReqChBTxLocalread-onlycurrentLocal device OAM Channel B TX Variable Request OAMPDU frame count
1.3.6.1.4.1.4756.20.190.40.1.145Columnf100ASOamVarReqChBRxLocalread-onlycurrentLocal device OAM Channel B RX Variable Request OAMPDU frame count
1.3.6.1.4.1.4756.20.190.40.1.146Columnf100ASOamVarRspChBTxLocalread-onlycurrentLocal device OAM Channel B TX Variable Response OAMPDU frame count
1.3.6.1.4.1.4756.20.190.40.1.147Columnf100ASOamVarRspChBRxLocalread-onlycurrentLocal device OAM Channel B RX Variable Response OAMPDU frame count
1.3.6.1.4.1.4756.20.190.40.1.148Columnf100ASOamOuiChBTxLocalread-onlycurrentLocal device OAM Channel B TX OUI OAMPDU frame count
1.3.6.1.4.1.4756.20.190.40.1.149Columnf100ASOamOuiChBRxLocalread-onlycurrentLocal device OAM Channel B RX OUI OAMPDU frame count
1.3.6.1.4.1.4756.20.190.40.1.150Columnf100ASOamUnknowChBRxLocalread-onlycurrentLocal device OAM Channel B RX Unsupported OAMPDU frame count
1.3.6.1.4.1.4756.20.190.40.1.151Columnf100ASFx1FEFLocalread-onlycurrentLocal card fiber1 detected Far End Fault: 0:Off 1:Detected
1.3.6.1.4.1.4756.20.190.40.1.152Columnf100ASFx2FEFLocalread-onlycurrentLocal card fiber2 detected Far End Fault: 0:Off 1:Detected
1.3.6.1.4.1.4756.20.190.40.1.153Columnf100ASIpModeLocalread-writecurrentOn Rack Ip Mode: 0:Enable 1:Disable
1.3.6.1.4.1.4756.20.190.40.1.154Columnf100ASFx1QosPriorityRateLocalread-writecurrentLocal device Fiber 1 Qos Priority Rate Mode: 0:Disable 1:Enable
1.3.6.1.4.1.4756.20.190.40.1.155Columnf100ASFx2QosPriorityRateLocalread-writecurrentLocal device Fiber 2 Qos Priority Rate Mode: 0:Disable 1:Enable
1.3.6.1.4.1.4756.20.190.40.1.156Columnf100ASUtp1QosPriorityRateLocalread-writecurrentLocal device Utp 3 Qos Priority Rate Mode: 0:Disable 1:Enable
1.3.6.1.4.1.4756.20.190.40.1.157Columnf100ASUtp2QosPriorityRateLocalread-writecurrentLocal device Utp 4 Qos Priority Rate Mode: 0:Disable 1:Enable
1.3.6.1.4.1.4756.20.190.40.1.158Columnf100ASFx1QosPortPriorityLocalread-writecurrentLocal device Fiber 1 Qos Port Priority : 0:priority 0 1:priority 1 2:priority 2 3:priority 3
1.3.6.1.4.1.4756.20.190.40.1.159Columnf100ASFx2QosPortPriorityLocalread-writecurrentLocal device Fiber 2 Qos Port Priority : 0:priority 0 1:priority 1 2:priority 2 3:priority 3
1.3.6.1.4.1.4756.20.190.40.1.160Columnf100ASUtp1QosPortPriorityLocalread-writecurrentLocal device Utp3 Qos Port Priority : 0:priority 0 1:priority 1 2:priority 2 3:priority 3
1.3.6.1.4.1.4756.20.190.40.1.161Columnf100ASUtp2QosPortPriorityLocalread-writecurrentLocal device Utp4 Qos Port Priority : 0:priority 0 1:priority 1 2:priority 2 3:priority 3
1.3.6.1.4.1.4756.20.190.40.1.162Columnf100ASSetDefaultLocalread-writecurrentLocal device Set to default: 0:Off 1:Action
1.3.6.1.4.1.4756.20.191Nodef100ASRemoteACards
1.3.6.1.4.1.4756.20.191.40Tablef100ASRemoteATablenot-accessiblecurrentA list of local frm220-100AS card entries. The number of entries is f100AS-NoRemoteA.
1.3.6.1.4.1.4756.20.191.40.1Rowf100ASRemoteAEntrynot-accessiblecurrentAn entry containing management information applicable to a particular local frm220-100AS card.
1.3.6.1.4.1.4756.20.191.40.1.1Columnf100ASChassisIndexRemoteAread-onlycurrentA unique value for each local card. It is the chassis location number.
1.3.6.1.4.1.4756.20.191.40.1.2Columnf100ASSlotIndexRemoteAread-onlycurrentA unique value for each local card. It is the slot location number.
1.3.6.1.4.1.4756.20.191.40.1.3Columnf100ASCardHWVerRemoteAread-onlycurrentRemote device card hardware version x.xxx
1.3.6.1.4.1.4756.20.191.40.1.4Columnf100ASCardFWVerRemoteAread-onlycurrentRemote device card firmware version x.xxx
1.3.6.1.4.1.4756.20.191.40.1.5Columnf100ASCardCPLDVerRemoteAread-onlycurrentRemote device card CPLD version x.xxx
1.3.6.1.4.1.4756.20.191.40.1.6Columnf100ASCardFPGAVerRemoteAread-onlycurrentRemote device card FPGA version x.xxx
1.3.6.1.4.1.4756.20.191.40.1.7Columnf100ASModelRemoteAread-onlycurrentRemote frm220 f100AS Serial Type
1.3.6.1.4.1.4756.20.191.40.1.8Columnf100ASFx1LinkRemoteAread-onlycurrentRemote device card fiber port 1 link status: 0:Down 1:Up
1.3.6.1.4.1.4756.20.191.40.1.9Columnf100ASFx1OAMLoopedRemoteAread-onlycurrentRemote device card fiber port 1 OAM looped: 0:Off 1:on
1.3.6.1.4.1.4756.20.191.40.1.10Columnf100ASFx1LBTestRemoteAread-writecurrentForce remote device card to do fiber port 1 LoopBack testing: 0:Off 1:Action
1.3.6.1.4.1.4756.20.191.40.1.11Columnf100ASFx1OAMRLBStatusRemoteAread-onlycurrentRemote device card fiber port 1 LoopBack testing status: 0:Off 1:Ok 2:Fail
1.3.6.1.4.1.4756.20.191.40.1.12Columnf100ASFx1RemoPwrAbRemoteAread-onlycurrentRemote device card fiber port 1 Remote Power status: 0:Abnormal 1:OK 2:None
1.3.6.1.4.1.4756.20.191.40.1.13Columnf100ASFx2LinkRemoteAread-onlycurrentRemote device card fiber port 2 link status: 0:Down 1:Up
1.3.6.1.4.1.4756.20.191.40.1.14Columnf100ASFx2OAMLoopedRemoteAread-onlycurrentRemote device card fiber port 2 OAM looped: 0:Off 1:on
1.3.6.1.4.1.4756.20.191.40.1.15Columnf100ASFx2LBTestRemoteAread-writecurrentForce remote device card to do fiber port 2 LoopBack testing: 0:Off 1:Action
1.3.6.1.4.1.4756.20.191.40.1.16Columnf100ASFx2OAMRLBStatusRemoteAread-onlycurrentRemote device card fiber port 1 LoopBack testing status: 0:Off 1:Ok 2:Fail
1.3.6.1.4.1.4756.20.191.40.1.17Columnf100ASFx2RemoPwrAbRemoteAread-onlycurrentRemote device card fiber port 2 Remote Power status: 0:Abnormal 1:OK 2:None
1.3.6.1.4.1.4756.20.191.40.1.18Columnf100ASUtp1LinkRemoteAread-onlycurrentRemote device card UTP port 3 link status: 0:Down 1:Up
1.3.6.1.4.1.4756.20.191.40.1.19Columnf100ASUtp1NegoRemoteAread-writecurrentRemote device card UTP port 3 negotiation status: 0:Manual 1:Auto
1.3.6.1.4.1.4756.20.191.40.1.20Columnf100ASUtp1SpeedRemoteAread-writecurrentRemote device card UTP port 3 speed setting: 0:10 Base-T 1:100 Base-TX
1.3.6.1.4.1.4756.20.191.40.1.21Columnf100ASUtp1DuplexRemoteAread-writecurrentRemote device card UTP port 3 duplex setting: 0:Half duplex mode 1:Full duplex mode
1.3.6.1.4.1.4756.20.191.40.1.22Columnf100ASUtp1SpeedStatusRemoteAread-onlycurrentRemote device card UTP port 3 speed status: 0:10 Base-T 1:100 Base-TX
1.3.6.1.4.1.4756.20.191.40.1.23Columnf100ASUtp1DuplexStatusRemoteAread-onlycurrentRemote device card UTP port 3 duplex status: 0:Half duplex mode 1:Full duplex mode
1.3.6.1.4.1.4756.20.191.40.1.24Columnf100ASUtp2LinkRemoteAread-onlycurrentRemote device card UTP port 4 link status: 0:Down 1:Up
1.3.6.1.4.1.4756.20.191.40.1.25Columnf100ASUtp2NegoRemoteAread-writecurrentRemote device card UTP port 4 negotiation status: 0:Manual 1:Auto
1.3.6.1.4.1.4756.20.191.40.1.26Columnf100ASUtp2SpeedRemoteAread-writecurrentRemote device card UTP port 4 speed setting: 0:10 Base-T 1:100 Base-TX
1.3.6.1.4.1.4756.20.191.40.1.27Columnf100ASUtp2DuplexRemoteAread-writecurrentRemote device card UTP port 2 duplex setting: 0:Half duplex mode 1:Full duplex mode
1.3.6.1.4.1.4756.20.191.40.1.28Columnf100ASUtp2SpeedStatusRemoteAread-onlycurrentRemote device card UTP port 4 speed status: 0:10 Base-T 1:100 Base-TX
1.3.6.1.4.1.4756.20.191.40.1.29Columnf100ASUtp2DuplexStatusRemoteAread-onlycurrentRemote device card UTP port 2 duplex status: 0:Half duplex mode 1:Full duplex mode
1.3.6.1.4.1.4756.20.191.40.1.30Columnf100ASFx1IrlModeRemoteAread-writecurrentRemote device card port 1 Rate Limit mode: 0:unlimited 1:limited
1.3.6.1.4.1.4756.20.191.40.1.31Columnf100ASFx1IrlIndexRemoteAread-writecurrentRemote device card port 1 Ingress Rate Limit index: Index Limit Rate 0 Disable 1 128K 2 256K 3 512K 4 1M 5 2M 6 4M 7 8M
1.3.6.1.4.1.4756.20.191.40.1.32Columnf100ASFx1ErlIndexRemoteAread-writecurrentRemote device card port 1 Egress Rate Limit index: Index Limit Rate 0 Disable 1 128K 2 256K 3 512K 4 1M 5 2M 6 4M 7 8M
1.3.6.1.4.1.4756.20.191.40.1.33Columnf100ASFx2IrlModeRemoteAread-writecurrentRemote device card port 2 Rate Limit mode: 0:unlimited 1:limited
1.3.6.1.4.1.4756.20.191.40.1.34Columnf100ASFx2IrlIndexRemoteAread-writecurrentRemote device card port 2 Ingress Rate Limit index: Index Limit Rate 0 Disable 1 128K 2 256K 3 512K 4 1M 5 2M 6 4M 7 8M
1.3.6.1.4.1.4756.20.191.40.1.35Columnf100ASFx2ErlIndexRemoteAread-writecurrentRemote device card port 2 Egress Rate Limit index: Index Limit Rate 0 Disable 1 128K 2 256K 3 512K 4 1M 5 2M 6 4M 7 8M
1.3.6.1.4.1.4756.20.191.40.1.36Columnf100ASUtp1IrlModeRemoteAread-writecurrentRemote device card port 3 Rate Limit mode: 0:unlimited 1:limited
1.3.6.1.4.1.4756.20.191.40.1.37Columnf100ASUtp1IrlIndexRemoteAread-writecurrentRemote device card port 3 Ingress Rate Limit index: Index Limit Rate 0 Disable 1 128K 2 256K 3 512K 4 1M 5 2M 6 4M 7 8M
1.3.6.1.4.1.4756.20.191.40.1.38Columnf100ASUtp1ErlIndexRemoteAread-writecurrentRemote device card port 3 Egress Rate Limit index: Index Limit Rate 0 Disable 1 128K 2 256K 3 512K 4 1M 5 2M 6 4M 7 8M
1.3.6.1.4.1.4756.20.191.40.1.39Columnf100ASUtp2IrlModeRemoteAread-writecurrentRemote device card port 4 Rate Limit mode: 0:unlimited 1:limited
1.3.6.1.4.1.4756.20.191.40.1.40Columnf100ASUtp2IrlIndexRemoteAread-writecurrentRemote device card port 4 Ingress Rate Limit index: Index Limit Rate 0 Disable 1 128K 2 256K 3 512K 4 1M 5 2M 6 4M 7 8M
1.3.6.1.4.1.4756.20.191.40.1.41Columnf100ASUtp2ErlIndexRemoteAread-writecurrentRemote device card port 4 Egress Rate Limit index: Index Limit Rate 0 Disable 1 128K 2 256K 3 512K 4 1M 5 2M 6 4M 7 8M
1.3.6.1.4.1.4756.20.191.40.1.42Columnf100ASDeviceActiveRemoteAread-onlycurrentRemote device card active mode: (It is read-only in local device.) 0:Disable 1:Enable
1.3.6.1.4.1.4756.20.191.40.1.43Columnf100ASDeviceResetRemoteAread-writecurrentForce remote device card to reset mode: 0:Off 1:Action
1.3.6.1.4.1.4756.20.191.40.1.44Columnf100ASFx1ActiveRemoteAread-onlycurrentRemote device fiber port 1 active mode: 0:Disable 1:Enable
1.3.6.1.4.1.4756.20.191.40.1.45Columnf100ASFx2ActiveRemoteAread-onlycurrentRemote device fiber port 2 active mode: 0:Disable 1:Enable
1.3.6.1.4.1.4756.20.191.40.1.46Columnf100ASUtp1ActiveRemoteAread-writecurrentRemote device UTP port 3 active mode: 0:Disable 1:Enable
1.3.6.1.4.1.4756.20.191.40.1.47Columnf100ASUtp2ActiveRemoteAread-writecurrentRemote device UTP port 4 active mode: 0:Disable 1:Enable
1.3.6.1.4.1.4756.20.191.40.1.48Columnf100ASOamChAModeRemoteAread-writecurrentRemote device OAM Channel A mode: 0:Passive 1:Active
1.3.6.1.4.1.4756.20.191.40.1.49Columnf100ASOamChBModeRemoteAread-writecurrentRemote device OAM Channel B mode: 0:Passive 1:Active
1.3.6.1.4.1.4756.20.191.40.1.50Columnf100ASOamMaxPDUsRemoteAread-writecurrentRemote device OAM max OAMPDU size: 60-1518 Octets
1.3.6.1.4.1.4756.20.191.40.1.51Columnf100ASFx1AlsRemoteAread-writecurrentRemote device card port 1 Auto Laser Shutdown mode: 0:Disable 1:Enable
1.3.6.1.4.1.4756.20.191.40.1.52Columnf100ASFx2AlsRemoteAread-writecurrentRemote device card port 2 Auto Laser Shutdown mode: 0:Disable 1:Enable
1.3.6.1.4.1.4756.20.191.40.1.53Columnf100ASPauseFrameRemoteAread-writecurrentRemote device card pause frame mode: 0:Disable 1:Enable
1.3.6.1.4.1.4756.20.191.40.1.54Columnf100ASFhrModeRemoteAread-writecurrentRemote device card accepts remote Fiber Hardware Reset mode: 0:Disable 1:Enable
1.3.6.1.4.1.4756.20.191.40.1.55Columnf100ASFx1LLFDepLogiRemoteAread-writecurrentRemote device card port 1 Link Loss Forwarding depends boolean logic: 0:and 1:or
1.3.6.1.4.1.4756.20.191.40.1.56Columnf100ASFx1LLFDepPort2RemoteAread-writecurrentRemote device card port 1 Link Loss Forwarding depends on port 2 Fiber Rx link: 0:don't care 1:selected
1.3.6.1.4.1.4756.20.191.40.1.57Columnf100ASFx1LLFDepPort3RemoteAread-writecurrentRemote device card port 1 Link Loss Forwarding depends on port 3 Ethernet Rx link: 0:don't care 1:selected
1.3.6.1.4.1.4756.20.191.40.1.58Columnf100ASFx1LLFDepPort4RemoteAread-writecurrentRemote device card port 1 Link Loss Forwarding depends on port 4 Ethernet Rx link: 0:don't care 1:selected
1.3.6.1.4.1.4756.20.191.40.1.59Columnf100ASFx2LLFDepLogiRemoteAread-writecurrentRemote device card port 2 Link Loss Forwarding depends boolean logic: 0:and 1:or
1.3.6.1.4.1.4756.20.191.40.1.60Columnf100ASFx2LLFDepPort1RemoteAread-writecurrentRemote device card port 2 Link Loss Forwarding depends on port 1 Fiber Rx link: 0:don't care 1:selected
1.3.6.1.4.1.4756.20.191.40.1.61Columnf100ASFx2LLFDepPort3RemoteAread-writecurrentRemote device card port 2 Link Loss Forwarding depends on port 3 Ethernet Rx link: 0:don't care 1:selected
1.3.6.1.4.1.4756.20.191.40.1.62Columnf100ASFx2LLFDepPort4RemoteAread-writecurrentRemote device card port 2 Link Loss Forwarding depends on port 4 Ethernet Rx link: 0:don't care 1:selected
1.3.6.1.4.1.4756.20.191.40.1.63Columnf100ASUtp1LLFDepLogiRemoteAread-writecurrentRemote device card port 3 Link Loss Forwarding depends boolean logic: 0:and 1:or
1.3.6.1.4.1.4756.20.191.40.1.64Columnf100ASUtp1LLFDepPort1RemoteAread-writecurrentRemote device card port 3 Link Loss Forwarding depends on port 1 Fiber Rx link: 0:don't care 1:selected
1.3.6.1.4.1.4756.20.191.40.1.65Columnf100ASUtp1LLFDepPort2RemoteAread-writecurrentRemote device card port 3 Link Loss Forwarding depends on port 2 Fiber Rx link: 0:don't care 1:selected
1.3.6.1.4.1.4756.20.191.40.1.66Columnf100ASUtp2LLFDepLogiRemoteAread-writecurrentRemote device card port 4 Link Loss Forwarding depends boolean logic: 0:and 1:or
1.3.6.1.4.1.4756.20.191.40.1.67Columnf100ASUtp2LLFDepPort1RemoteAread-writecurrentRemote device card port 4 Link Loss Forwarding depends on port 1 Fiber Rx link: 0:don't care 1:selected
1.3.6.1.4.1.4756.20.191.40.1.68Columnf100ASUtp2LLFDepPort2RemoteAread-writecurrentRemote device card port 4 Link Loss Forwarding depends on port 2 Fiber Rx link: 0:don't care 1:selected
1.3.6.1.4.1.4756.20.191.40.1.69Columnf100ASAdvanceFunsRemoteAread-writecurrentRemote device card Switch functions mode: 0:Normal 2:Port 1&2 Mirror 3:Port VLAN 1/3;2/4 4:Port 1&2 Redundancy 5:Static 802.1Q VLAN 6:Spanning Tree protocol 7:…
1.3.6.1.4.1.4756.20.191.40.1.70Columnf100ASFx1InfoROM1RemoteAread-onlycurrentRemote device card port 1 INFORemoteOM information 1 valid: 0:Invalid 1:Valid
1.3.6.1.4.1.4756.20.191.40.1.71Columnf100ASFx1InfoROM2RemoteAread-onlycurrentRemote device card port 1 INFORemoteOM information 2 valid: 0:Invalid 1:Valid(replacing D/D function
1.3.6.1.4.1.4756.20.191.40.1.72Columnf100ASFx2InfoROM1RemoteAread-onlycurrentRemote device card port 2 INFORemoteOM information 1 valid: 0:Invalid 1:Valid
1.3.6.1.4.1.4756.20.191.40.1.73Columnf100ASFx2InfoROM2RemoteAread-onlycurrentRemote device card port 2 INFORemoteOM information 2 valid: 0:Invalid 1:Valid(replacing D/D function)
1.3.6.1.4.1.4756.20.191.40.1.74Columnf100ASFx1InfoSN1RemoteAread-onlycurrentRemote device card port 1 INFORemoteOM S/N 1
1.3.6.1.4.1.4756.20.191.40.1.75Columnf100ASFx1InfoSN2RemoteAread-onlycurrentRemote device card port 1 INFORemoteOM S/N 2
1.3.6.1.4.1.4756.20.191.40.1.76Columnf100ASFx2InfoSN1RemoteAread-onlycurrentRemote device card port 2 INFORemoteOM S/N 1
1.3.6.1.4.1.4756.20.191.40.1.77Columnf100ASFx2InfoSN2RemoteAread-onlycurrentRemote device card port 2 INFORemoteOM S/N 2
1.3.6.1.4.1.4756.20.191.40.1.78Columnf100ASFx1DDRemoteAread-onlycurrentRemote device card fiber port 1 Digital Diagnostic function: 0:No 1:Yes
1.3.6.1.4.1.4756.20.191.40.1.79Columnf100ASFx1DDVendorRemoteAread-onlycurrentRemote device card fiber port 1 D/D information: Vendor name
1.3.6.1.4.1.4756.20.191.40.1.80Columnf100ASFx1DDPartNoRemoteAread-onlycurrentRemote device card fiber port 1 D/D information: Vendor part number
1.3.6.1.4.1.4756.20.191.40.1.81Columnf100ASFx1DDFiberTypeRemoteAread-onlycurrentRemote device card fiber port 1 D/D information: Fiber Type
1.3.6.1.4.1.4756.20.191.40.1.82Columnf100ASFx1DDWaveLenRemoteAread-onlycurrentRemote device card fiber port 1 D/D information: Wave length
1.3.6.1.4.1.4756.20.191.40.1.83Columnf100ASFx1DDWaveLen2RemoteAread-onlycurrentRemote device card fiber port 1 D/D information: Wave length 2
1.3.6.1.4.1.4756.20.191.40.1.84Columnf100ASFx1DDLinkLenRemoteAread-onlycurrentRemote device card fiber port 1 D/D information: Link length
1.3.6.1.4.1.4756.20.191.40.1.85Columnf100ASFx1DDLenUnitRemoteAread-onlycurrentRemote device card fiber port 1 D/D information: Length Unit
1.3.6.1.4.1.4756.20.191.40.1.86Columnf100ASFx1DDStatusRemoteAread-onlycurrentRemote device card fiber port 1 D/D information: Status Support
1.3.6.1.4.1.4756.20.191.40.1.87Columnf100ASFx1DDRxSensRemoteAread-onlycurrentRemote device card fiber port 1 D/D information: Rx Sensitivity
1.3.6.1.4.1.4756.20.191.40.1.88Columnf100ASFx1DDTxPWRRemoteAread-onlycurrentRemote device card fiber port 1 D/D information: Tx power
1.3.6.1.4.1.4756.20.191.40.1.89Columnf100ASFx1DDRxPWRRemoteAread-onlycurrentRemote device card fiber port 1 D/D information: Rx power
1.3.6.1.4.1.4756.20.191.40.1.90Columnf100ASFx1DDTempRemoteAread-onlycurrentRemote device card fiber port 1 D/D information: Temperature in degree C
1.3.6.1.4.1.4756.20.191.40.1.91Columnf100ASFx1DDPWRMarginRemoteAread-onlycurrentRemote device card fiber port 1 D/D information: Power margin
1.3.6.1.4.1.4756.20.191.40.1.92Columnf100ASFx1DDPWRLossRemoteAread-onlycurrentRemote device card fiber port 1 D/D information: Power loss
1.3.6.1.4.1.4756.20.191.40.1.93Columnf100ASFx2DDRemoteAread-onlycurrentRemote device card fiber port 2 Digital Diagnostic function: 0:No 1:Yes
1.3.6.1.4.1.4756.20.191.40.1.94Columnf100ASFx2DDVendorRemoteAread-onlycurrentRemote device card fiber port 2 D/D information: Vendor name
1.3.6.1.4.1.4756.20.191.40.1.95Columnf100ASFx2DDPartNoRemoteAread-onlycurrentRemote device card fiber port 2 D/D information: Vendor part number
1.3.6.1.4.1.4756.20.191.40.1.96Columnf100ASFx2DDFiberTypeRemoteAread-onlycurrentRemote device card fiber port 2 D/D information: Fiber Type
1.3.6.1.4.1.4756.20.191.40.1.97Columnf100ASFx2DDWaveLenRemoteAread-onlycurrentRemote device card fiber port 2 D/D information: Wave length
1.3.6.1.4.1.4756.20.191.40.1.98Columnf100ASFx2DDWaveLen2RemoteAread-onlycurrentRemote device card fiber port 2 D/D information: Wave length 2
1.3.6.1.4.1.4756.20.191.40.1.99Columnf100ASFx2DDLinkLenRemoteAread-onlycurrentRemote device card fiber port 2 D/D information: Link length
1.3.6.1.4.1.4756.20.191.40.1.100Columnf100ASFx2DDLenUnitRemoteAread-onlycurrentRemote device card fiber port 2 D/D information: Length Unit
1.3.6.1.4.1.4756.20.191.40.1.101Columnf100ASFx2DDStatusRemoteAread-onlycurrentRemote device card fiber port 2 D/D information: Status Support
1.3.6.1.4.1.4756.20.191.40.1.102Columnf100ASFx2DDRxSensRemoteAread-onlycurrentRemote device card fiber port 2 D/D information: Rx Sensitivity
1.3.6.1.4.1.4756.20.191.40.1.103Columnf100ASFx2DDTxPWRRemoteAread-onlycurrentRemote device card fiber port 2 D/D information: Tx power
1.3.6.1.4.1.4756.20.191.40.1.104Columnf100ASFx2DDRxPWRRemoteAread-onlycurrentRemote device card fiber port 2 D/D information: Rx power
1.3.6.1.4.1.4756.20.191.40.1.105Columnf100ASFx2DDTempRemoteAread-onlycurrentRemote device card fiber port 2 D/D information: Temperature in degree C
1.3.6.1.4.1.4756.20.191.40.1.106Columnf100ASFx2DDPWRMarginRemoteAread-onlycurrentRemote device card fiber port 2 D/D information: Power margin
1.3.6.1.4.1.4756.20.191.40.1.107Columnf100ASFx2DDPWRLossRemoteAread-onlycurrentRemote device card fiber port 2 D/D information: Power loss
1.3.6.1.4.1.4756.20.191.40.1.108Columnf100ASClrRMONCntsRemoteAread-writecurrentClear local device card RMON IN/OUT counters: 0:No action 1:Action
1.3.6.1.4.1.4756.20.191.40.1.109Columnf100ASFx1RMONInRemoteAread-onlycurrentRemote device card port 1 RMON IN counter.
1.3.6.1.4.1.4756.20.191.40.1.110Columnf100ASFx1RMONOutRemoteAread-onlycurrentRemote device card port 1 RMON OUT counter.
1.3.6.1.4.1.4756.20.191.40.1.111Columnf100ASFx2RMONInRemoteAread-onlycurrentRemote device card port 2 RMON IN counter.
1.3.6.1.4.1.4756.20.191.40.1.112Columnf100ASFx2RMONOutRemoteAread-onlycurrentRemote device card port 2 RMON OUT counter.
1.3.6.1.4.1.4756.20.191.40.1.113Columnf100ASUtp1RMONInRemoteAread-onlycurrentRemote device card port 3 RMON IN counter.
1.3.6.1.4.1.4756.20.191.40.1.114Columnf100ASUtp1RMONOutRemoteAread-onlycurrentRemote device card port 3 RMON OUT counter.
1.3.6.1.4.1.4756.20.191.40.1.115Columnf100ASUtp2RMONInRemoteAread-onlycurrentRemote device card port 4 RMON IN counter.
1.3.6.1.4.1.4756.20.191.40.1.116Columnf100ASUtp2RMONOutRemoteAread-onlycurrentRemote device card port 4 RMON OUT counter.
1.3.6.1.4.1.4756.20.191.40.1.117Columnf100ASClrOAMCntsRemoteAread-writecurrentClear local device card OAM counters: 0:No action 1:Action
1.3.6.1.4.1.4756.20.191.40.1.118Columnf100ASOamChATxRemoteAread-onlycurrentRemote device OAM Channel A TX OAMPDU frame count
1.3.6.1.4.1.4756.20.191.40.1.119Columnf100ASOamChARxRemoteAread-onlycurrentRemote device OAM Channel A RX OAMPDU frame count
1.3.6.1.4.1.4756.20.191.40.1.120Columnf100ASOamInfoChATxRemoteAread-onlycurrentRemote device OAM Channel A TX Information OAMPDU frame count
1.3.6.1.4.1.4756.20.191.40.1.121Columnf100ASOamInfoChARxRemoteAread-onlycurrentRemote device OAM Channel A RX Information OAMPDU frame count
1.3.6.1.4.1.4756.20.191.40.1.122Columnf100ASOamEventChATxRemoteAread-onlycurrentRemote device OAM Channel A TX Event OAMPDU frame count
1.3.6.1.4.1.4756.20.191.40.1.123Columnf100ASOamUniEvtChARxRemoteAread-onlycurrentRemote device OAM Channel A RX Unique Event OAMPDU frame count
1.3.6.1.4.1.4756.20.191.40.1.124Columnf100ASOamDupEvtChARxRemoteAread-onlycurrentRemote device OAM Channel A RX Duplicate Event OAMPDU frame count
1.3.6.1.4.1.4756.20.191.40.1.125Columnf100ASOamLbChATxRemoteAread-onlycurrentRemote device OAM Channel A TX Loopback Control OAMPDU frame count
1.3.6.1.4.1.4756.20.191.40.1.126Columnf100ASOamLbChARxRemoteAread-onlycurrentRemote device OAM Channel A RX Loopback Control OAMPDU frame count
1.3.6.1.4.1.4756.20.191.40.1.127Columnf100ASOamVarReqChATxRemoteAread-onlycurrentRemote device OAM Channel A TX Variable Request OAMPDU frame count
1.3.6.1.4.1.4756.20.191.40.1.128Columnf100ASOamVarReqChARxRemoteAread-onlycurrentRemote device OAM Channel A RX Variable Request OAMPDU frame count
1.3.6.1.4.1.4756.20.191.40.1.129Columnf100ASOamVarRspChATxRemoteAread-onlycurrentRemote device OAM Channel A TX Variable Response OAMPDU frame count
1.3.6.1.4.1.4756.20.191.40.1.130Columnf100ASOamVarRspChARxRemoteAread-onlycurrentRemote device OAM Channel A RX Variable Response OAMPDU frame count
1.3.6.1.4.1.4756.20.191.40.1.131Columnf100ASOamOuiChATxRemoteAread-onlycurrentRemote device OAM Channel A TX OUI OAMPDU frame count
1.3.6.1.4.1.4756.20.191.40.1.132Columnf100ASOamOuiChARxRemoteAread-onlycurrentRemote device OAM Channel A RX OUI OAMPDU frame count
1.3.6.1.4.1.4756.20.191.40.1.133Columnf100ASOamUnknowChARxRemoteAread-onlycurrentRemote device OAM Channel A RX Unsupported OAMPDU frame count
1.3.6.1.4.1.4756.20.191.40.1.134Columnf100ASOamChBTxRemoteAread-onlycurrentRemote device OAM Channel B TX OAMPDU frame count
1.3.6.1.4.1.4756.20.191.40.1.135Columnf100ASOamChBRxRemoteAread-onlycurrentRemote device OAM Channel B RX OAMPDU frame count
1.3.6.1.4.1.4756.20.191.40.1.136Columnf100ASOamInfoChBTxRemoteAread-onlycurrentRemote device OAM Channel B TX Information OAMPDU frame count
1.3.6.1.4.1.4756.20.191.40.1.137Columnf100ASOamInfoChBRxRemoteAread-onlycurrentRemote device OAM Channel B RX Information OAMPDU frame count
1.3.6.1.4.1.4756.20.191.40.1.138Columnf100ASOamEventChBTxRemoteAread-onlycurrentRemote device OAM Channel B TX Event OAMPDU frame count
1.3.6.1.4.1.4756.20.191.40.1.139Columnf100ASOamUniEvtChBRxRemoteAread-onlycurrentRemote device OAM Channel B RX Unique Event OAMPDU frame count
1.3.6.1.4.1.4756.20.191.40.1.140Columnf100ASOamDupEvtChBRxRemoteAread-onlycurrentRemote device OAM Channel B RX Duplicate Event OAMPDU frame count
1.3.6.1.4.1.4756.20.191.40.1.141Columnf100ASOamLbChBTxRemoteAread-onlycurrentRemote device OAM Channel B TX Loopback Control OAMPDU frame count
1.3.6.1.4.1.4756.20.191.40.1.142Columnf100ASOamLbChBRxRemoteAread-onlycurrentRemote device OAM Channel B RX Loopback Control OAMPDU frame count
1.3.6.1.4.1.4756.20.191.40.1.143Columnf100ASOamVarReqChBTxRemoteAread-onlycurrentRemote device OAM Channel B TX Variable Request OAMPDU frame count
1.3.6.1.4.1.4756.20.191.40.1.144Columnf100ASOamVarReqChBRxRemoteAread-onlycurrentRemote device OAM Channel B RX Variable Request OAMPDU frame count
1.3.6.1.4.1.4756.20.191.40.1.145Columnf100ASOamVarRspChBTxRemoteAread-onlycurrentRemote device OAM Channel B TX Variable Response OAMPDU frame count
1.3.6.1.4.1.4756.20.191.40.1.146Columnf100ASOamVarRspChBRxRemoteAread-onlycurrentRemote device OAM Channel B RX Variable Response OAMPDU frame count
1.3.6.1.4.1.4756.20.191.40.1.147Columnf100ASOamOuiChBTxRemoteAread-onlycurrentRemote device OAM Channel B TX OUI OAMPDU frame count
1.3.6.1.4.1.4756.20.191.40.1.148Columnf100ASOamOuiChBRxRemoteAread-onlycurrentRemote device OAM Channel B RX OUI OAMPDU frame count
1.3.6.1.4.1.4756.20.191.40.1.149Columnf100ASOamUnknowChBRxRemoteAread-onlycurrentRemote device OAM Channel B RX Unsupported OAMPDU frame count
1.3.6.1.4.1.4756.20.191.40.1.150Columnf100ASFx1FEFRemoteAread-onlycurrentRemote card fiber1 detected Far End Fault: 0:Off 1:Detected
1.3.6.1.4.1.4756.20.191.40.1.151Columnf100ASFx2FEFRemoteAread-onlycurrentRemote card fiber2 detected Far End Fault: 0:Off 1:Detected
1.3.6.1.4.1.4756.20.191.40.1.152Columnf100ASPower1RemoteAread-onlycurrentRemote card OFC type power1 status: 0:Normal 1:Fail 2:None
1.3.6.1.4.1.4756.20.191.40.1.153Columnf100ASPower2RemoteAread-onlycurrentRemote card OFC type power2 status: 0:Normal 1:Fail 2:None
1.3.6.1.4.1.4756.20.191.40.1.154Columnf100ASIpModeRemoteAread-writecurrentOn Rack Ip Mode: 0:Enable 1:Disable
1.3.6.1.4.1.4756.20.191.40.1.155Columnf100ASFx1QosPriorityRateRemoteAread-writecurrentLocal device Fiber 1 Qos Priority Rate Mode: 0:Disable 1:Enable
1.3.6.1.4.1.4756.20.191.40.1.156Columnf100ASFx2QosPriorityRateRemoteAread-writecurrentLocal device Fiber 2 Qos Priority Rate Mode: 0:Disable 1:Enable
1.3.6.1.4.1.4756.20.191.40.1.157Columnf100ASUtp1QosPriorityRateRemoteAread-writecurrentRemote device Utp 3 Qos Priority Rate Mode: 0:Disable 1:Enable
1.3.6.1.4.1.4756.20.191.40.1.158Columnf100ASUtp2QosPriorityRateRemoteAread-writecurrentRemote device Utp 4 Qos Priority Rate Mode: 0:Disable 1:Enable
1.3.6.1.4.1.4756.20.191.40.1.159Columnf100ASFx1QosPortPriorityRemoteAread-writecurrentRemote device Fiber 1 Qos Port Priority : 0:priority 0 1:priority 1 2:priority 2 3:priority 3
1.3.6.1.4.1.4756.20.191.40.1.160Columnf100ASFx2QosPortPriorityRemoteAread-writecurrentRemote device Fiber 2 Qos Port Priority : 0:priority 0 1:priority 1 2:priority 2 3:priority 3
1.3.6.1.4.1.4756.20.191.40.1.161Columnf100ASUtp1QosPortPriorityRemoteAread-writecurrentRemote device Utp3 Qos Port Priority : 0:priority 0 1:priority 1 2:priority 2 3:priority 3
1.3.6.1.4.1.4756.20.191.40.1.162Columnf100ASUtp2QosPortPriorityRemoteAread-writecurrentRemote device Utp4 Qos Port Priority : 0:priority 0 1:priority 1 2:priority 2 3:priority 3
1.3.6.1.4.1.4756.20.191.40.1.163Columnf100ASSetDefaultRemoteAread-writecurrentRemote device Set to default: 0:Off 1:Action
1.3.6.1.4.1.4756.20.192Nodef100ASRemoteBCards
1.3.6.1.4.1.4756.20.192.40Tablef100ASRemoteBTablenot-accessiblecurrentA list of local frm220-100AS card entries. The number of entries is f100AS-NoRemoteB.
1.3.6.1.4.1.4756.20.192.40.1Rowf100ASRemoteBEntrynot-accessiblecurrentAn entry containing management information applicable to a particular local frm220-100AS card.
1.3.6.1.4.1.4756.20.192.40.1.1Columnf100ASChassisIndexRemoteBread-onlycurrentA unique value for each local card. It is the chassis location number.
1.3.6.1.4.1.4756.20.192.40.1.2Columnf100ASSlotIndexRemoteBread-onlycurrentA unique value for each local card. It is the slot location number.
1.3.6.1.4.1.4756.20.192.40.1.3Columnf100ASCardHWVerRemoteBread-onlycurrentRemote device card hardware version x.xxx
1.3.6.1.4.1.4756.20.192.40.1.4Columnf100ASCardFWVerRemoteBread-onlycurrentRemote device card firmware version x.xxx
1.3.6.1.4.1.4756.20.192.40.1.5Columnf100ASCardCPLDVerRemoteBread-onlycurrentRemote device card CPLD version x.xxx
1.3.6.1.4.1.4756.20.192.40.1.6Columnf100ASCardFPGAVerRemoteBread-onlycurrentRemote device card FPGA version x.xxx
1.3.6.1.4.1.4756.20.192.40.1.7Columnf100ASModelRemoteBread-onlycurrentRemote frm220 f100AS Serial Type
1.3.6.1.4.1.4756.20.192.40.1.8Columnf100ASFx1LinkRemoteBread-onlycurrentRemote device card fiber port 1 link status: 0:Down 1:Up
1.3.6.1.4.1.4756.20.192.40.1.9Columnf100ASFx1OAMLoopedRemoteBread-onlycurrentRemote device card fiber port 1 OAM looped: 0:Off 1:on
1.3.6.1.4.1.4756.20.192.40.1.10Columnf100ASFx1LBTestRemoteBread-writecurrentForce remote device card to do fiber port 1 LoopBack testing: 0:Off 1:Action
1.3.6.1.4.1.4756.20.192.40.1.11Columnf100ASFx1OAMRLBStatusRemoteBread-onlycurrentRemote device card fiber port 1 LoopBack testing status: 0:Off 1:Ok 2:Fail
1.3.6.1.4.1.4756.20.192.40.1.12Columnf100ASFx1RemoPwrAbRemoteBread-onlycurrentRemote device card fiber port 1 Remote Power status: 0:Abnormal 1:OK 2:None
1.3.6.1.4.1.4756.20.192.40.1.13Columnf100ASFx2LinkRemoteBread-onlycurrentRemote device card fiber port 2 link status: 0:Down 1:Up
1.3.6.1.4.1.4756.20.192.40.1.14Columnf100ASFx2OAMLoopedRemoteBread-onlycurrentRemote device card fiber port 2 OAM looped: 0:Off 1:on
1.3.6.1.4.1.4756.20.192.40.1.15Columnf100ASFx2LBTestRemoteBread-writecurrentForce remote device card to do fiber port 2 LoopBack testing: 0:Off 1:Action
1.3.6.1.4.1.4756.20.192.40.1.16Columnf100ASFx2OAMRLBStatusRemoteBread-onlycurrentRemote device card fiber port 1 LoopBack testing status: 0:Off 1:Ok 2:Fail
1.3.6.1.4.1.4756.20.192.40.1.17Columnf100ASFx2RemoPwrAbRemoteBread-onlycurrentRemote device card fiber port 2 Remote Power status: 0:Abnormal 1:OK 2:None
1.3.6.1.4.1.4756.20.192.40.1.18Columnf100ASUtp1LinkRemoteBread-onlycurrentRemote device card UTP port 3 link status: 0:Down 1:Up
1.3.6.1.4.1.4756.20.192.40.1.19Columnf100ASUtp1NegoRemoteBread-writecurrentRemote device card UTP port 3 negotiation status: 0:Manual 1:Auto
1.3.6.1.4.1.4756.20.192.40.1.20Columnf100ASUtp1SpeedRemoteBread-writecurrentRemote device card UTP port 3 speed setting: 0:10 Base-T 1:100 Base-TX
1.3.6.1.4.1.4756.20.192.40.1.21Columnf100ASUtp1DuplexRemoteBread-writecurrentRemote device card UTP port 3 duplex setting: 0:Half duplex mode 1:Full duplex mode
1.3.6.1.4.1.4756.20.192.40.1.22Columnf100ASUtp1SpeedStatusRemoteBread-onlycurrentRemote device card UTP port 3 speed status: 0:10 Base-T 1:100 Base-TX
1.3.6.1.4.1.4756.20.192.40.1.23Columnf100ASUtp1DuplexStatusRemoteBread-onlycurrentRemote device card UTP port 3 duplex status: 0:Half duplex mode 1:Full duplex mode
1.3.6.1.4.1.4756.20.192.40.1.24Columnf100ASUtp2LinkRemoteBread-onlycurrentRemote device card UTP port 4 link status: 0:Down 1:Up
1.3.6.1.4.1.4756.20.192.40.1.25Columnf100ASUtp2NegoRemoteBread-writecurrentRemote device card UTP port 4 negotiation status: 0:Manual 1:Auto
1.3.6.1.4.1.4756.20.192.40.1.26Columnf100ASUtp2SpeedRemoteBread-writecurrentRemote device card UTP port 4 speed setting: 0:10 Base-T 1:100 Base-TX
1.3.6.1.4.1.4756.20.192.40.1.27Columnf100ASUtp2DuplexRemoteBread-writecurrentRemote device card UTP port 2 duplex setting: 0:Half duplex mode 1:Full duplex mode
1.3.6.1.4.1.4756.20.192.40.1.28Columnf100ASUtp2SpeedStatusRemoteBread-onlycurrentRemote device card UTP port 4 speed status: 0:10 Base-T 1:100 Base-TX
1.3.6.1.4.1.4756.20.192.40.1.29Columnf100ASUtp2DuplexStatusRemoteBread-onlycurrentRemote device card UTP port 2 duplex status: 0:Half duplex mode 1:Full duplex mode
1.3.6.1.4.1.4756.20.192.40.1.30Columnf100ASFx1IrlModeRemoteBread-writecurrentRemote device card port 1 Rate Limit mode: 0:unlimited 1:limited
1.3.6.1.4.1.4756.20.192.40.1.31Columnf100ASFx1IrlIndexRemoteBread-writecurrentRemote device card port 1 Ingress Rate Limit index: Index Limit Rate 0 Disable 1 128K 2 256K 3 512K 4 1M 5 2M 6 4M 7 8M
1.3.6.1.4.1.4756.20.192.40.1.32Columnf100ASFx1ErlIndexRemoteBread-writecurrentRemote device card port 1 Egress Rate Limit index: Index Limit Rate 0 Disable 1 128K 2 256K 3 512K 4 1M 5 2M 6 4M 7 8M
1.3.6.1.4.1.4756.20.192.40.1.33Columnf100ASFx2IrlModeRemoteBread-writecurrentRemote device card port 2 Rate Limit mode: 0:unlimited 1:limited
1.3.6.1.4.1.4756.20.192.40.1.34Columnf100ASFx2IrlIndexRemoteBread-writecurrentRemote device card port 2 Ingress Rate Limit index: Index Limit Rate 0 Disable 1 128K 2 256K 3 512K 4 1M 5 2M 6 4M 7 8M
1.3.6.1.4.1.4756.20.192.40.1.35Columnf100ASFx2ErlIndexRemoteBread-writecurrentRemote device card port 2 Egress Rate Limit index: Index Limit Rate 0 Disable 1 128K 2 256K 3 512K 4 1M 5 2M 6 4M 7 8M
1.3.6.1.4.1.4756.20.192.40.1.36Columnf100ASUtp1IrlModeRemoteBread-writecurrentRemote device card port 3 Rate Limit mode: 0:unlimited 1:limited
1.3.6.1.4.1.4756.20.192.40.1.37Columnf100ASUtp1IrlIndexRemoteBread-writecurrentRemote device card port 3 Ingress Rate Limit index: Index Limit Rate 0 Disable 1 128K 2 256K 3 512K 4 1M 5 2M 6 4M 7 8M
1.3.6.1.4.1.4756.20.192.40.1.38Columnf100ASUtp1ErlIndexRemoteBread-writecurrentRemote device card port 3 Egress Rate Limit index: Index Limit Rate 0 Disable 1 128K 2 256K 3 512K 4 1M 5 2M 6 4M 7 8M
1.3.6.1.4.1.4756.20.192.40.1.39Columnf100ASUtp2IrlModeRemoteBread-writecurrentRemote device card port 4 Rate Limit mode: 0:unlimited 1:limited
1.3.6.1.4.1.4756.20.192.40.1.40Columnf100ASUtp2IrlIndexRemoteBread-writecurrentRemote device card port 4 Ingress Rate Limit index: Index Limit Rate 0 Disable 1 128K 2 256K 3 512K 4 1M 5 2M 6 4M 7 8M
1.3.6.1.4.1.4756.20.192.40.1.41Columnf100ASUtp2ErlIndexRemoteBread-writecurrentRemote device card port 4 Egress Rate Limit index: Index Limit Rate 0 Disable 1 128K 2 256K 3 512K 4 1M 5 2M 6 4M 7 8M
1.3.6.1.4.1.4756.20.192.40.1.42Columnf100ASDeviceActiveRemoteBread-onlycurrentRemote device card active mode: (It is read-only in local device.) 0:Disable 1:Enable
1.3.6.1.4.1.4756.20.192.40.1.43Columnf100ASDeviceResetRemoteBread-writecurrentForce remote device card to reset mode: 0:Off 1:Action
1.3.6.1.4.1.4756.20.192.40.1.44Columnf100ASFx1ActiveRemoteBread-onlycurrentRemote device fiber port 1 active mode: 0:Disable 1:Enable
1.3.6.1.4.1.4756.20.192.40.1.45Columnf100ASFx2ActiveRemoteBread-onlycurrentRemote device fiber port 2 active mode: 0:Disable 1:Enable
1.3.6.1.4.1.4756.20.192.40.1.46Columnf100ASUtp1ActiveRemoteBread-writecurrentRemote device UTP port 3 active mode: 0:Disable 1:Enable
1.3.6.1.4.1.4756.20.192.40.1.47Columnf100ASUtp2ActiveRemoteBread-writecurrentRemote device UTP port 4 active mode: 0:Disable 1:Enable
1.3.6.1.4.1.4756.20.192.40.1.48Columnf100ASOamChAModeRemoteBread-writecurrentRemote device OAM Channel A mode: 0:Passive 1:Active
1.3.6.1.4.1.4756.20.192.40.1.49Columnf100ASOamChBModeRemoteBread-writecurrentRemote device OAM Channel B mode: 0:Passive 1:Active
1.3.6.1.4.1.4756.20.192.40.1.50Columnf100ASOamMaxPDUsRemoteBread-writecurrentRemote device OAM max OAMPDU size: 60-1518 Octets
1.3.6.1.4.1.4756.20.192.40.1.51Columnf100ASFx1AlsRemoteBread-writecurrentRemote device card port 1 Auto Laser Shutdown mode: 0:Disable 1:Enable
1.3.6.1.4.1.4756.20.192.40.1.52Columnf100ASFx2AlsRemoteBread-writecurrentRemote device card port 2 Auto Laser Shutdown mode: 0:Disable 1:Enable
1.3.6.1.4.1.4756.20.192.40.1.53Columnf100ASPauseFrameRemoteBread-writecurrentRemote device card pause frame mode: 0:Disable 1:Enable
1.3.6.1.4.1.4756.20.192.40.1.54Columnf100ASFhrModeRemoteBread-writecurrentRemote device card accepts remote Fiber Hardware Reset mode: 0:Disable 1:Enable
1.3.6.1.4.1.4756.20.192.40.1.55Columnf100ASFx1LLFDepLogiRemoteBread-writecurrentRemote device card port 1 Link Loss Forwarding depends boolean logic: 0:and 1:or
1.3.6.1.4.1.4756.20.192.40.1.56Columnf100ASFx1LLFDepPort2RemoteBread-writecurrentRemote device card port 1 Link Loss Forwarding depends on port 2 Fiber Rx link: 0:don't care 1:selected
1.3.6.1.4.1.4756.20.192.40.1.57Columnf100ASFx1LLFDepPort3RemoteBread-writecurrentRemote device card port 1 Link Loss Forwarding depends on port 3 Ethernet Rx link: 0:don't care 1:selected
1.3.6.1.4.1.4756.20.192.40.1.58Columnf100ASFx1LLFDepPort4RemoteBread-writecurrentRemote device card port 1 Link Loss Forwarding depends on port 4 Ethernet Rx link: 0:don't care 1:selected
1.3.6.1.4.1.4756.20.192.40.1.59Columnf100ASFx2LLFDepLogiRemoteBread-writecurrentRemote device card port 2 Link Loss Forwarding depends boolean logic: 0:and 1:or
1.3.6.1.4.1.4756.20.192.40.1.60Columnf100ASFx2LLFDepPort1RemoteBread-writecurrentRemote device card port 2 Link Loss Forwarding depends on port 1 Fiber Rx link: 0:don't care 1:selected
1.3.6.1.4.1.4756.20.192.40.1.61Columnf100ASFx2LLFDepPort3RemoteBread-writecurrentRemote device card port 2 Link Loss Forwarding depends on port 3 Ethernet Rx link: 0:don't care 1:selected
1.3.6.1.4.1.4756.20.192.40.1.62Columnf100ASFx2LLFDepPort4RemoteBread-writecurrentRemote device card port 2 Link Loss Forwarding depends on port 4 Ethernet Rx link: 0:don't care 1:selected
1.3.6.1.4.1.4756.20.192.40.1.63Columnf100ASUtp1LLFDepLogiRemoteBread-writecurrentRemote device card port 3 Link Loss Forwarding depends boolean logic: 0:and 1:or
1.3.6.1.4.1.4756.20.192.40.1.64Columnf100ASUtp1LLFDepPort1RemoteBread-writecurrentRemote device card port 3 Link Loss Forwarding depends on port 1 Fiber Rx link: 0:don't care 1:selected
1.3.6.1.4.1.4756.20.192.40.1.65Columnf100ASUtp1LLFDepPort2RemoteBread-writecurrentRemote device card port 3 Link Loss Forwarding depends on port 2 Fiber Rx link: 0:don't care 1:selected
1.3.6.1.4.1.4756.20.192.40.1.66Columnf100ASUtp2LLFDepLogiRemoteBread-writecurrentRemote device card port 4 Link Loss Forwarding depends boolean logic: 0:and 1:or
1.3.6.1.4.1.4756.20.192.40.1.67Columnf100ASUtp2LLFDepPort1RemoteBread-writecurrentRemote device card port 4 Link Loss Forwarding depends on port 1 Fiber Rx link: 0:don't care 1:selected
1.3.6.1.4.1.4756.20.192.40.1.68Columnf100ASUtp2LLFDepPort2RemoteBread-writecurrentRemote device card port 4 Link Loss Forwarding depends on port 2 Fiber Rx link: 0:don't care 1:selected
1.3.6.1.4.1.4756.20.192.40.1.69Columnf100ASAdvanceFunsRemoteBread-writecurrentRemote device card Switch functions mode: 0:Normal 2:Port 1&2 Mirror 3:Port VLAN 1/3;2/4 4:Port 1&2 Redundancy 5:Static 802.1Q VLAN 6:Spanning Tree protocol 7:…
1.3.6.1.4.1.4756.20.192.40.1.70Columnf100ASFx1InfoROM1RemoteBread-onlycurrentRemote device card port 1 INFORemoteOM information 1 valid: 0:Invalid 1:Valid
1.3.6.1.4.1.4756.20.192.40.1.71Columnf100ASFx1InfoROM2RemoteBread-onlycurrentRemote device card port 1 INFORemoteOM information 2 valid: 0:Invalid 1:Valid(replacing D/D function
1.3.6.1.4.1.4756.20.192.40.1.72Columnf100ASFx2InfoROM1RemoteBread-onlycurrentRemote device card port 2 INFORemoteOM information 1 valid: 0:Invalid 1:Valid
1.3.6.1.4.1.4756.20.192.40.1.73Columnf100ASFx2InfoROM2RemoteBread-onlycurrentRemote device card port 2 INFORemoteOM information 2 valid: 0:Invalid 1:Valid(replacing D/D function)
1.3.6.1.4.1.4756.20.192.40.1.74Columnf100ASFx1InfoSN1RemoteBread-onlycurrentRemote device card port 1 INFORemoteOM S/N 1
1.3.6.1.4.1.4756.20.192.40.1.75Columnf100ASFx1InfoSN2RemoteBread-onlycurrentRemote device card port 1 INFORemoteOM S/N 2
1.3.6.1.4.1.4756.20.192.40.1.76Columnf100ASFx2InfoSN1RemoteBread-onlycurrentRemote device card port 2 INFORemoteOM S/N 1
1.3.6.1.4.1.4756.20.192.40.1.77Columnf100ASFx2InfoSN2RemoteBread-onlycurrentRemote device card port 2 INFORemoteOM S/N 2
1.3.6.1.4.1.4756.20.192.40.1.78Columnf100ASFx1DDRemoteBread-onlycurrentRemote device card fiber port 1 Digital Diagnostic function: 0:No 1:Yes
1.3.6.1.4.1.4756.20.192.40.1.79Columnf100ASFx1DDVendorRemoteBread-onlycurrentRemote device card fiber port 1 D/D information: Vendor name
1.3.6.1.4.1.4756.20.192.40.1.80Columnf100ASFx1DDPartNoRemoteBread-onlycurrentRemote device card fiber port 1 D/D information: Vendor part number
1.3.6.1.4.1.4756.20.192.40.1.81Columnf100ASFx1DDFiberTypeRemoteBread-onlycurrentRemote device card fiber port 1 D/D information: Fiber Type
1.3.6.1.4.1.4756.20.192.40.1.82Columnf100ASFx1DDWaveLenRemoteBread-onlycurrentRemote device card fiber port 1 D/D information: Wave length
1.3.6.1.4.1.4756.20.192.40.1.83Columnf100ASFx1DDWaveLen2RemoteBread-onlycurrentRemote device card fiber port 1 D/D information: Wave length 2
1.3.6.1.4.1.4756.20.192.40.1.84Columnf100ASFx1DDLinkLenRemoteBread-onlycurrentRemote device card fiber port 1 D/D information: Link length
1.3.6.1.4.1.4756.20.192.40.1.85Columnf100ASFx1DDLenUnitRemoteBread-onlycurrentRemote device card fiber port 1 D/D information: Length Unit
1.3.6.1.4.1.4756.20.192.40.1.86Columnf100ASFx1DDStatusRemoteBread-onlycurrentRemote device card fiber port 1 D/D information: Status Support
1.3.6.1.4.1.4756.20.192.40.1.87Columnf100ASFx1DDRxSensRemoteBread-onlycurrentRemote device card fiber port 1 D/D information: Rx Sensitivity
1.3.6.1.4.1.4756.20.192.40.1.88Columnf100ASFx1DDTxPWRRemoteBread-onlycurrentRemote device card fiber port 1 D/D information: Tx power
1.3.6.1.4.1.4756.20.192.40.1.89Columnf100ASFx1DDRxPWRRemoteBread-onlycurrentRemote device card fiber port 1 D/D information: Rx power
1.3.6.1.4.1.4756.20.192.40.1.90Columnf100ASFx1DDTempRemoteBread-onlycurrentRemote device card fiber port 1 D/D information: Temperature in degree C
1.3.6.1.4.1.4756.20.192.40.1.91Columnf100ASFx1DDPWRMarginRemoteBread-onlycurrentRemote device card fiber port 1 D/D information: Power margin
1.3.6.1.4.1.4756.20.192.40.1.92Columnf100ASFx1DDPWRLossRemoteBread-onlycurrentRemote device card fiber port 1 D/D information: Power loss
1.3.6.1.4.1.4756.20.192.40.1.93Columnf100ASFx2DDRemoteBread-onlycurrentRemote device card fiber port 2 Digital Diagnostic function: 0:No 1:Yes
1.3.6.1.4.1.4756.20.192.40.1.94Columnf100ASFx2DDVendorRemoteBread-onlycurrentRemote device card fiber port 2 D/D information: Vendor name
1.3.6.1.4.1.4756.20.192.40.1.95Columnf100ASFx2DDPartNoRemoteBread-onlycurrentRemote device card fiber port 2 D/D information: Vendor part number
1.3.6.1.4.1.4756.20.192.40.1.96Columnf100ASFx2DDFiberTypeRemoteBread-onlycurrentRemote device card fiber port 2 D/D information: Fiber Type
1.3.6.1.4.1.4756.20.192.40.1.97Columnf100ASFx2DDWaveLenRemoteBread-onlycurrentRemote device card fiber port 2 D/D information: Wave length
1.3.6.1.4.1.4756.20.192.40.1.98Columnf100ASFx2DDWaveLen2RemoteBread-onlycurrentRemote device card fiber port 2 D/D information: Wave length 2
1.3.6.1.4.1.4756.20.192.40.1.99Columnf100ASFx2DDLinkLenRemoteBread-onlycurrentRemote device card fiber port 2 D/D information: Link length
1.3.6.1.4.1.4756.20.192.40.1.100Columnf100ASFx2DDLenUnitRemoteBread-onlycurrentRemote device card fiber port 2 D/D information: Length Unit
1.3.6.1.4.1.4756.20.192.40.1.101Columnf100ASFx2DDStatusRemoteBread-onlycurrentRemote device card fiber port 2 D/D information: Status Support
1.3.6.1.4.1.4756.20.192.40.1.102Columnf100ASFx2DDRxSensRemoteBread-onlycurrentRemote device card fiber port 2 D/D information: Rx Sensitivity
1.3.6.1.4.1.4756.20.192.40.1.103Columnf100ASFx2DDTxPWRRemoteBread-onlycurrentRemote device card fiber port 2 D/D information: Tx power
1.3.6.1.4.1.4756.20.192.40.1.104Columnf100ASFx2DDRxPWRRemoteBread-onlycurrentRemote device card fiber port 2 D/D information: Rx power
1.3.6.1.4.1.4756.20.192.40.1.105Columnf100ASFx2DDTempRemoteBread-onlycurrentRemote device card fiber port 2 D/D information: Temperature in degree C
1.3.6.1.4.1.4756.20.192.40.1.106Columnf100ASFx2DDPWRMarginRemoteBread-onlycurrentRemote device card fiber port 2 D/D information: Power margin
1.3.6.1.4.1.4756.20.192.40.1.107Columnf100ASFx2DDPWRLossRemoteBread-onlycurrentRemote device card fiber port 2 D/D information: Power loss
1.3.6.1.4.1.4756.20.192.40.1.108Columnf100ASClrRMONCntsRemoteBread-writecurrentClear local device card RMON IN/OUT counters: 0:No action 1:Action
1.3.6.1.4.1.4756.20.192.40.1.109Columnf100ASFx1RMONInRemoteBread-onlycurrentRemote device card port 1 RMON IN counter.
1.3.6.1.4.1.4756.20.192.40.1.110Columnf100ASFx1RMONOutRemoteBread-onlycurrentRemote device card port 1 RMON OUT counter.
1.3.6.1.4.1.4756.20.192.40.1.111Columnf100ASFx2RMONInRemoteBread-onlycurrentRemote device card port 2 RMON IN counter.
1.3.6.1.4.1.4756.20.192.40.1.112Columnf100ASFx2RMONOutRemoteBread-onlycurrentRemote device card port 2 RMON OUT counter.
1.3.6.1.4.1.4756.20.192.40.1.113Columnf100ASUtp1RMONInRemoteBread-onlycurrentRemote device card port 3 RMON IN counter.
1.3.6.1.4.1.4756.20.192.40.1.114Columnf100ASUtp1RMONOutRemoteBread-onlycurrentRemote device card port 3 RMON OUT counter.
1.3.6.1.4.1.4756.20.192.40.1.115Columnf100ASUtp2RMONInRemoteBread-onlycurrentRemote device card port 4 RMON IN counter.
1.3.6.1.4.1.4756.20.192.40.1.116Columnf100ASUtp2RMONOutRemoteBread-onlycurrentRemote device card port 4 RMON OUT counter.
1.3.6.1.4.1.4756.20.192.40.1.117Columnf100ASClrOAMCntsRemoteBread-writecurrentClear local device card OAM counters: 0:No action 1:Action
1.3.6.1.4.1.4756.20.192.40.1.118Columnf100ASOamChATxRemoteBread-onlycurrentRemote device OAM Channel A TX OAMPDU frame count
1.3.6.1.4.1.4756.20.192.40.1.119Columnf100ASOamChARxRemoteBread-onlycurrentRemote device OAM Channel A RX OAMPDU frame count
1.3.6.1.4.1.4756.20.192.40.1.120Columnf100ASOamInfoChATxRemoteBread-onlycurrentRemote device OAM Channel A TX Information OAMPDU frame count
1.3.6.1.4.1.4756.20.192.40.1.121Columnf100ASOamInfoChARxRemoteBread-onlycurrentRemote device OAM Channel A RX Information OAMPDU frame count
1.3.6.1.4.1.4756.20.192.40.1.122Columnf100ASOamEventChATxRemoteBread-onlycurrentRemote device OAM Channel A TX Event OAMPDU frame count
1.3.6.1.4.1.4756.20.192.40.1.123Columnf100ASOamUniEvtChARxRemoteBread-onlycurrentRemote device OAM Channel A RX Unique Event OAMPDU frame count
1.3.6.1.4.1.4756.20.192.40.1.124Columnf100ASOamDupEvtChARxRemoteBread-onlycurrentRemote device OAM Channel A RX Duplicate Event OAMPDU frame count
1.3.6.1.4.1.4756.20.192.40.1.125Columnf100ASOamLbChATxRemoteBread-onlycurrentRemote device OAM Channel A TX Loopback Control OAMPDU frame count
1.3.6.1.4.1.4756.20.192.40.1.126Columnf100ASOamLbChARxRemoteBread-onlycurrentRemote device OAM Channel A RX Loopback Control OAMPDU frame count
1.3.6.1.4.1.4756.20.192.40.1.127Columnf100ASOamVarReqChATxRemoteBread-onlycurrentRemote device OAM Channel A TX Variable Request OAMPDU frame count
1.3.6.1.4.1.4756.20.192.40.1.128Columnf100ASOamVarReqChARxRemoteBread-onlycurrentRemote device OAM Channel A RX Variable Request OAMPDU frame count
1.3.6.1.4.1.4756.20.192.40.1.129Columnf100ASOamVarRspChATxRemoteBread-onlycurrentRemote device OAM Channel A TX Variable Response OAMPDU frame count
1.3.6.1.4.1.4756.20.192.40.1.130Columnf100ASOamVarRspChARxRemoteBread-onlycurrentRemote device OAM Channel A RX Variable Response OAMPDU frame count
1.3.6.1.4.1.4756.20.192.40.1.131Columnf100ASOamOuiChATxRemoteBread-onlycurrentRemote device OAM Channel A TX OUI OAMPDU frame count
1.3.6.1.4.1.4756.20.192.40.1.132Columnf100ASOamOuiChARxRemoteBread-onlycurrentRemote device OAM Channel A RX OUI OAMPDU frame count
1.3.6.1.4.1.4756.20.192.40.1.133Columnf100ASOamUnknowChARxRemoteBread-onlycurrentRemote device OAM Channel A RX Unsupported OAMPDU frame count
1.3.6.1.4.1.4756.20.192.40.1.134Columnf100ASOamChBTxRemoteBread-onlycurrentRemote device OAM Channel B TX OAMPDU frame count
1.3.6.1.4.1.4756.20.192.40.1.135Columnf100ASOamChBRxRemoteBread-onlycurrentRemote device OAM Channel B RX OAMPDU frame count
1.3.6.1.4.1.4756.20.192.40.1.136Columnf100ASOamInfoChBTxRemoteBread-onlycurrentRemote device OAM Channel B TX Information OAMPDU frame count
1.3.6.1.4.1.4756.20.192.40.1.137Columnf100ASOamInfoChBRxRemoteBread-onlycurrentRemote device OAM Channel B RX Information OAMPDU frame count
1.3.6.1.4.1.4756.20.192.40.1.138Columnf100ASOamEventChBTxRemoteBread-onlycurrentRemote device OAM Channel B TX Event OAMPDU frame count
1.3.6.1.4.1.4756.20.192.40.1.139Columnf100ASOamUniEvtChBRxRemoteBread-onlycurrentRemote device OAM Channel B RX Unique Event OAMPDU frame count
1.3.6.1.4.1.4756.20.192.40.1.140Columnf100ASOamDupEvtChBRxRemoteBread-onlycurrentRemote device OAM Channel B RX Duplicate Event OAMPDU frame count
1.3.6.1.4.1.4756.20.192.40.1.141Columnf100ASOamLbChBTxRemoteBread-onlycurrentRemote device OAM Channel B TX Loopback Control OAMPDU frame count
1.3.6.1.4.1.4756.20.192.40.1.142Columnf100ASOamLbChBRxRemoteBread-onlycurrentRemote device OAM Channel B RX Loopback Control OAMPDU frame count
1.3.6.1.4.1.4756.20.192.40.1.143Columnf100ASOamVarReqChBTxRemoteBread-onlycurrentRemote device OAM Channel B TX Variable Request OAMPDU frame count
1.3.6.1.4.1.4756.20.192.40.1.144Columnf100ASOamVarReqChBRxRemoteBread-onlycurrentRemote device OAM Channel B RX Variable Request OAMPDU frame count
1.3.6.1.4.1.4756.20.192.40.1.145Columnf100ASOamVarRspChBTxRemoteBread-onlycurrentRemote device OAM Channel B TX Variable Response OAMPDU frame count
1.3.6.1.4.1.4756.20.192.40.1.146Columnf100ASOamVarRspChBRxRemoteBread-onlycurrentRemote device OAM Channel B RX Variable Response OAMPDU frame count
1.3.6.1.4.1.4756.20.192.40.1.147Columnf100ASOamOuiChBTxRemoteBread-onlycurrentRemote device OAM Channel B TX OUI OAMPDU frame count
1.3.6.1.4.1.4756.20.192.40.1.148Columnf100ASOamOuiChBRxRemoteBread-onlycurrentRemote device OAM Channel B RX OUI OAMPDU frame count
1.3.6.1.4.1.4756.20.192.40.1.149Columnf100ASOamUnknowChBRxRemoteBread-onlycurrentRemote device OAM Channel B RX Unsupported OAMPDU frame count
1.3.6.1.4.1.4756.20.192.40.1.150Columnf100ASFx1FEFRemoteBread-onlycurrentRemote card fiber1 detected Far End Fault: 0:Off 1:Detected
1.3.6.1.4.1.4756.20.192.40.1.151Columnf100ASFx2FEFRemoteBread-onlycurrentRemote card fiber2 detected Far End Fault: 0:Off 1:Detected
1.3.6.1.4.1.4756.20.192.40.1.152Columnf100ASPower1RemoteBread-onlycurrentRemote card OFC type power1 status: 0:Normal 1:Fail 2:None
1.3.6.1.4.1.4756.20.192.40.1.153Columnf100ASPower2RemoteBread-onlycurrentRemote card OFC type power2 status: 0:Normal 1:Fail 2:None
1.3.6.1.4.1.4756.20.192.40.1.154Columnf100ASIpModeRemoteBread-writecurrentOn Rack Ip Mode: 0:Enable 1:Disable
1.3.6.1.4.1.4756.20.192.40.1.155Columnf100ASFx1QosPriorityRateRemoteBread-writecurrentLocal device Fiber 1 Qos Priority Rate Mode: 0:Disable 1:Enable
1.3.6.1.4.1.4756.20.192.40.1.156Columnf100ASFx2QosPriorityRateRemoteBread-writecurrentLocal device Fiber 2 Qos Priority Rate Mode: 0:Disable 1:Enable
1.3.6.1.4.1.4756.20.192.40.1.157Columnf100ASUtp1QosPriorityRateRemoteBread-writecurrentRemote device Utp 3 Qos Priority Rate Mode: 0:Disable 1:Enable
1.3.6.1.4.1.4756.20.192.40.1.158Columnf100ASUtp2QosPriorityRateRemoteBread-writecurrentRemote device Utp 4 Qos Priority Rate Mode: 0:Disable 1:Enable
1.3.6.1.4.1.4756.20.192.40.1.159Columnf100ASFx1QosPortPriorityRemoteBread-writecurrentRemote device Fiber 1 Qos Port Priority : 0:priority 0 1:priority 1 2:priority 2 3:priority 3
1.3.6.1.4.1.4756.20.192.40.1.160Columnf100ASFx2QosPortPriorityRemoteBread-writecurrentRemote device Fiber 2 Qos Port Priority : 0:priority 0 1:priority 1 2:priority 2 3:priority 3
1.3.6.1.4.1.4756.20.192.40.1.161Columnf100ASUtp1QosPortPriorityRemoteBread-writecurrentRemote device Utp3 Qos Port Priority : 0:priority 0 1:priority 1 2:priority 2 3:priority 3
1.3.6.1.4.1.4756.20.192.40.1.162Columnf100ASUtp2QosPortPriorityRemoteBread-writecurrentRemote device Utp4 Qos Port Priority : 0:priority 0 1:priority 1 2:priority 2 3:priority 3
1.3.6.1.4.1.4756.20.192.40.1.163Columnf100ASSetDefaultRemoteBread-writecurrentLocal device Set to default: 0:Off 1:Action
1.3.6.1.4.1.4756.20.200NodefMDCards
1.3.6.1.4.1.4756.20.200.20TablefMDTablenot-accessiblecurrentA list of local FRM220-MUX/DEMUX card entries. The number of entries is fMD cards.
1.3.6.1.4.1.4756.20.200.20.1RowfMDEntrynot-accessiblecurrentAn entry containing management information applicable to a particular local FRM220-MUX/DEMUX card.
1.3.6.1.4.1.4756.20.200.20.1.1ColumnfMDChassisIndexread-onlycurrentA unique value for each local card. It is the chassis location number.
1.3.6.1.4.1.4756.20.200.20.1.2ColumnfMDSlotIndexread-onlycurrentA unique value for each local card. It is the slot location number.
1.3.6.1.4.1.4756.20.200.20.1.3ColumnfMDCardHWVerread-onlycurrentLocal FRM220-3R27G card hardware version x.xxx
1.3.6.1.4.1.4756.20.200.20.1.4ColumnfMDCardFWVerread-onlycurrentLocal FRM220-3R27G card firmware version x.xxx
1.3.6.1.4.1.4756.20.200.20.1.5ColumnfMDCardCPLDVerread-onlycurrentLocal FRM220-3R27G card CPLD version x.xxx
1.3.6.1.4.1.4756.20.200.20.1.6ColumnfMDCardFPGAVerread-onlycurrentLocal FRM220-3R27G card FPGA version x.xxx
1.3.6.1.4.1.4756.20.200.20.1.7ColumnfMDModelread-onlycurrentLocal CardType: 0:CWMD40-KLMN 1:FRM220-MD40-UP02 2:CWMD82-IJKLMNOP 3:CWMD40-MNOP 4:CWMD80-IJKLMNOP 5:CWMD40B-JLNP 6:CWMD40A-IKMO 11:CWMD41A-IKMO 12:CWMD41B-JLN…
1.3.6.1.4.1.4756.20.200.20.1.8ColumnfMDOpNumread-onlycurrentNumber of Optical Information:
1.3.6.1.4.1.4756.20.200.20.1.9ColumnfMDUpgradeNumread-onlycurrentNumber of Upgrade Channel:
1.3.6.1.4.1.4756.20.200.20.1.10ColumnfMDMonitorPortread-onlycurrentLocal FRM220-MUX/DEMUX monitor port
1.3.6.1.4.1.4756.20.200.20.1.11ColumnfMDWaveLen1read-onlycurrentLocal FRM220-MUX/DEMUX card WaveLen 1
1.3.6.1.4.1.4756.20.200.20.1.12ColumnfMDWaveLen2read-onlycurrentLocal FRM220-MUX/DEMUX card WaveLen 2
1.3.6.1.4.1.4756.20.200.20.1.13ColumnfMDWaveLen3read-onlycurrentLocal FRM220-MUX/DEMUX card WaveLen 3
1.3.6.1.4.1.4756.20.200.20.1.14ColumnfMDWaveLen4read-onlycurrentLocal FRM220-MUX/DEMUX card WaveLen 4
1.3.6.1.4.1.4756.20.200.20.1.15ColumnfMDWaveLen5read-onlycurrentLocal FRM220-MUX/DEMUX card WaveLen 5
1.3.6.1.4.1.4756.20.200.20.1.16ColumnfMDWaveLen6read-onlycurrentLocal FRM220-MUX/DEMUX card WaveLen 6
1.3.6.1.4.1.4756.20.200.20.1.17ColumnfMDWaveLen7read-onlycurrentLocal FRM220-MUX/DEMUX card WaveLen 7
1.3.6.1.4.1.4756.20.200.20.1.18ColumnfMDWaveLen8read-onlycurrentLocal FRM220-MUX/DEMUX card WaveLen 8
1.3.6.1.4.1.4756.20.200.20.1.19ColumnfMDWaveLen9read-onlycurrentLocal FRM220-MUX/DEMUX card WaveLen 9
1.3.6.1.4.1.4756.20.200.20.1.20ColumnfMDWaveLen10read-onlycurrentLocal FRM220-MUX/DEMUX card WaveLen 10
1.3.6.1.4.1.4756.20.200.20.1.21ColumnfMDWaveLen11read-onlycurrentLocal FRM220-MUX/DEMUX card WaveLen 11
1.3.6.1.4.1.4756.20.200.20.1.22ColumnfMDWaveLen12read-onlycurrentLocal FRM220-MUX/DEMUX card WaveLen 12
1.3.6.1.4.1.4756.20.200.20.1.23ColumnfMDWaveLen13read-onlycurrentLocal FRM220-MUX/DEMUX card WaveLen 13
1.3.6.1.4.1.4756.20.200.20.1.24ColumnfMDWaveLen14read-onlycurrentLocal FRM220-MUX/DEMUX card WaveLen 14
1.3.6.1.4.1.4756.20.200.20.1.25ColumnfMDWaveLen15read-onlycurrentLocal FRM220-MUX/DEMUX card WaveLen 15
1.3.6.1.4.1.4756.20.200.20.1.26ColumnfMDWaveLen16read-onlycurrentLocal FRM220-MUX/DEMUX card WaveLen 16
1.3.6.1.4.1.4756.20.200.20.1.27ColumnfMDRxWaveLen1read-onlycurrentLocal FRM220-MUX/DEMUX card RxWaveLen 1
1.3.6.1.4.1.4756.20.200.20.1.28ColumnfMDRxWaveLen2read-onlycurrentLocal FRM220-MUX/DEMUX card RxWaveLen 2
1.3.6.1.4.1.4756.20.200.20.1.29ColumnfMDRxWaveLen3read-onlycurrentLocal FRM220-MUX/DEMUX card RxWaveLen 3
1.3.6.1.4.1.4756.20.200.20.1.30ColumnfMDRxWaveLen4read-onlycurrentLocal FRM220-MUX/DEMUX card RxWaveLen 4
1.3.6.1.4.1.4756.20.200.20.1.31ColumnfMDRxWaveLen5read-onlycurrentLocal FRM220-MUX/DEMUX card RxWaveLen 5
1.3.6.1.4.1.4756.20.200.20.1.32ColumnfMDRxWaveLen6read-onlycurrentLocal FRM220-MUX/DEMUX card RxWaveLen 6
1.3.6.1.4.1.4756.20.200.20.1.33ColumnfMDRxWaveLen7read-onlycurrentLocal FRM220-MUX/DEMUX card RxWaveLen 7
1.3.6.1.4.1.4756.20.200.20.1.34ColumnfMDRxWaveLen8read-onlycurrentLocal FRM220-MUX/DEMUX card RxWaveLen 8
1.3.6.1.4.1.4756.20.200.20.1.35ColumnfMDRxWaveLen9read-onlycurrentLocal FRM220-MUX/DEMUX card RxWaveLen 9
1.3.6.1.4.1.4756.20.200.20.1.36ColumnfMDRxWaveLen10read-onlycurrentLocal FRM220-MUX/DEMUX card RxWaveLen 10
1.3.6.1.4.1.4756.20.200.20.1.37ColumnfMDRxWaveLen11read-onlycurrentLocal FRM220-MUX/DEMUX card RxWaveLen 11
1.3.6.1.4.1.4756.20.200.20.1.38ColumnfMDRxWaveLen12read-onlycurrentLocal FRM220-MUX/DEMUX card RxWaveLen 12
1.3.6.1.4.1.4756.20.200.20.1.39ColumnfMDRxWaveLen13read-onlycurrentLocal FRM220-MUX/DEMUX card RxWaveLen 13
1.3.6.1.4.1.4756.20.200.20.1.40ColumnfMDRxWaveLen14read-onlycurrentLocal FRM220-MUX/DEMUX card RxWaveLen 14
1.3.6.1.4.1.4756.20.200.20.1.41ColumnfMDRxWaveLen15read-onlycurrentLocal FRM220-MUX/DEMUX card RxWaveLen 15
1.3.6.1.4.1.4756.20.200.20.1.42ColumnfMDRxWaveLen16read-onlycurrentLocal FRM220-MUX/DEMUX card RxWaveLen 16
1.3.6.1.4.1.4756.20.200.20.1.43ColumnfMDChannel1Startread-onlycurrentLocal FRM220-MUX/DEMUX card upgrade channel 1 information
1.3.6.1.4.1.4756.20.200.20.1.44ColumnfMDChannel1Endread-onlycurrentLocal FRM220-MUX/DEMUX card upgrade channel information
1.3.6.1.4.1.4756.20.200.20.1.45ColumnfMDChannel2Startread-onlycurrentLocal FRM220-MUX/DEMUX card upgrade channel 2 information
1.3.6.1.4.1.4756.20.200.20.1.46ColumnfMDChannel2Endread-onlycurrentLocal FRM220-MUX/DEMUX card upgrade channe 2 information
1.3.6.1.4.1.4756.20.200.20.1.47ColumnfMDChannel3Startread-onlycurrentLocal FRM220-MUX/DEMUX card upgrade channel 3 information
1.3.6.1.4.1.4756.20.200.20.1.48ColumnfMDChannel3Endread-onlycurrentLocal FRM220-MUX/DEMUX card upgrade channe 3 information
1.3.6.1.4.1.4756.20.200.20.1.49ColumnfMDChannel4Startread-onlycurrentLocal FRM220-MUX/DEMUX card upgrade channel 4 information
1.3.6.1.4.1.4756.20.200.20.1.50ColumnfMDChannel4Endread-onlycurrentLocal FRM220-MUX/DEMUX card upgrade channe 4 information
1.3.6.1.4.1.4756.20.200.20.1.51ColumnfMDChannel5Startread-onlycurrentLocal FRM220-MUX/DEMUX card upgrade channel 5 information
1.3.6.1.4.1.4756.20.200.20.1.52ColumnfMDChannel5Endread-onlycurrentLocal FRM220-MUX/DEMUX card upgrade channe 5 information
1.3.6.1.4.1.4756.20.200.20.1.53ColumnfMDChannel6Startread-onlycurrentLocal FRM220-MUX/DEMUX card upgrade channel 6 information
1.3.6.1.4.1.4756.20.200.20.1.54ColumnfMDChannel6Endread-onlycurrentLocal FRM220-MUX/DEMUX card upgrade channe 6 information
1.3.6.1.4.1.4756.20.200.20.1.55ColumnfMDChannel7Startread-onlycurrentLocal FRM220-MUX/DEMUX card upgrade channel 7 information
1.3.6.1.4.1.4756.20.200.20.1.56ColumnfMDChannel7Endread-onlycurrentLocal FRM220-MUX/DEMUX card upgrade channe 7 information
1.3.6.1.4.1.4756.20.200.20.1.57ColumnfMDChannel8Startread-onlycurrentLocal FRM220-MUX/DEMUX card upgrade channel 8 information
1.3.6.1.4.1.4756.20.200.20.1.58ColumnfMDChannel8Endread-onlycurrentLocal FRM220-MUX/DEMUX card upgrade channe 8 information
1.3.6.1.4.1.4756.20.210Nodef3R10GCards
1.3.6.1.4.1.4756.20.210.20Tablef3R10GTablenot-accessiblecurrentA list of local FRM220-3R10G card entries. The number of entries is f3R10G-No-L.
1.3.6.1.4.1.4756.20.210.20.1Rowf3R10GEntrynot-accessiblecurrentAn entry containing management information applicable to a particular local FRM220-3R10G card.
1.3.6.1.4.1.4756.20.210.20.1.1Columnf3R10GChassisIndexread-onlycurrentA unique value for each local card. It is the chassis location number.
1.3.6.1.4.1.4756.20.210.20.1.2Columnf3R10GSlotIndexread-onlycurrentA unique value for each local card. It is the slot location number.
1.3.6.1.4.1.4756.20.210.20.1.3Columnf3R10GCardHWVerread-onlycurrentLocal FRM220-3R10G card hardware version x.xxx
1.3.6.1.4.1.4756.20.210.20.1.4Columnf3R10GCardFWVerread-onlycurrentLocal FRM220-3R10G card firmware version x.xxx
1.3.6.1.4.1.4756.20.210.20.1.5Columnf3R10GCardCPLDVerread-onlycurrentLocal FRM220-3R10G card CPLD version x.xxx
1.3.6.1.4.1.4756.20.210.20.1.6Columnf3R10GCardFPGAVerread-onlycurrentLocal FRM220-3R10G card FPGA version x.xxx
1.3.6.1.4.1.4756.20.210.20.1.7Columnf3R10GModelread-onlycurrentLocal CardType: 0:FRM220-3R10G/SS 1:FRM220-3R10G/SX 2:FRM220-3R10G/XX
1.3.6.1.4.1.4756.20.210.20.1.8Columnf3R10GDeviceActiveread-writecurrentLocal FRM220-3R10G card active: 0:Inactive 1:Active
1.3.6.1.4.1.4756.20.210.20.1.9Columnf3R10GFx1Linkread-onlycurrentLocal FRM220-3R10G card Fiber1 link status: 0:Down 1:Up
1.3.6.1.4.1.4756.20.210.20.1.10Columnf3R10GFx2Linkread-onlycurrentLocal FRM220-3R10G card Fiber2 link status: 0:Down 1:Up
1.3.6.1.4.1.4756.20.210.20.1.11Columnf3R10GFx1CRDLockedread-onlycurrentLocal FRM220-3R10G card Fiber1 CRD Locked: 0:Not Locked 1:Locked
1.3.6.1.4.1.4756.20.210.20.1.12Columnf3R10GFx2CRDLockedread-onlycurrentLocal FRM220-3R10G card Fiber2 CRD Locked: 0:Not Locked 1:Locked
1.3.6.1.4.1.4756.20.210.20.1.13Columnf3R10GFx1LossPropagationread-writecurrentLocal FRM220-3R10G card Fiber1 Loss Propagation: 0:Disable 1:Enable
1.3.6.1.4.1.4756.20.210.20.1.14Columnf3R10GFx2LossPropagationread-writecurrentLocal FRM220-3R10G card Fiber2 Loss Propagation: 0:Disable 1:Enable
1.3.6.1.4.1.4756.20.210.20.1.15Columnf3R10GFx1AlsModeread-writecurrentLocal FRM220-3R10G card Fiber1 Auto Laser Showdown: 0:Disable 1:Enable
1.3.6.1.4.1.4756.20.210.20.1.16Columnf3R10GFx2AlsModeread-writecurrentLocal FRM220-3R10G card Fiber2 Auto Laser Showdown: 0:Disable 1:Enable
1.3.6.1.4.1.4756.20.210.20.1.17Columnf3R10GPortResetread-writecurrentForce local FRM220-3R10G card to reset mode: 0:Off 1:Action
1.3.6.1.4.1.4756.20.210.20.1.18Columnf3R10GSetDefaultread-writecurrentLocal FRM220-3R10G card set to default : 0:Off 1:Action
1.3.6.1.4.1.4756.20.210.20.1.19Columnf3R10GSystemOKread-onlycurrentLocal FRM220-3R10G card system status: 0:Failure 1:Ok
1.3.6.1.4.1.4756.20.210.20.1.20Columnf3R10GFx1Lbsettingread-writecurrentLocal FRM220-3R10G card Fiber1 Loopback: 0:Off 1:On
1.3.6.1.4.1.4756.20.210.20.1.21Columnf3R10GFx2Lbsettingread-writecurrentLocal FRM220-3R10G card Fiber1 Loopback: 0:Off 1:On
1.3.6.1.4.1.4756.20.210.20.1.22Columnf3R10GLbEnableread-writecurrentLocal FRM220-3R10G card Loopback mode: 0:Disable 1:Enable
1.3.6.1.4.1.4756.20.210.20.1.23Columnf3R10GBaudRateread-writecurrentLocal FRM220-3R10G card BaudRate: 0:10G Ethernet 1:10G Fiber Channel 2:OC-192/STM-64 3:G.709 OTU2 4:1G Fiber Channel 5:2G Fiber Channel 6:4G Fiber Channel 7:8G…
1.3.6.1.4.1.4756.20.210.20.1.24Columnf3R10GFx1TxFailread-onlycurrentLocal FRM220-3R10G card Fx1 transceiver Tx detect 0:Normal 1:Fail
1.3.6.1.4.1.4756.20.210.20.1.25Columnf3R10GFx2TxFailread-onlycurrentLocal FRM220-3R10G card Fx2 transceiver Tx detect 0:Normal 1:Fail
1.3.6.1.4.1.4756.20.210.20.1.26Columnf3R10GFx1DDread-onlycurrentLocal FRM220-3R10G card fiber Digital Diagnostic function: 0:No 1:Yes
1.3.6.1.4.1.4756.20.210.20.1.27Columnf3R10GFx1DDVendorread-onlycurrentLocal FRM220-3R10G card fiber D/D information: Vendor name
1.3.6.1.4.1.4756.20.210.20.1.28Columnf3R10GFx1DDPartNoread-onlycurrentLocal FRM220-3R10G card fiber D/D information: Vendor part number
1.3.6.1.4.1.4756.20.210.20.1.29Columnf3R10GFx1DDFiberTyperead-onlycurrentLocal FRM220-3R10G card fiber D/D information: Fiber Type
1.3.6.1.4.1.4756.20.210.20.1.30Columnf3R10GFx1DDWaveLenread-onlycurrentLocal FRM220-3R10G card fiber D/D information: Wave length
1.3.6.1.4.1.4756.20.210.20.1.31Columnf3R10GFx1DDWaveLen2read-onlycurrentLocal FRM220-3R10G card fiber D/D information: Wave length 2
1.3.6.1.4.1.4756.20.210.20.1.32Columnf3R10GFx1DDLinkLenread-onlycurrentLocal FRM220-3R10G card fiber D/D information: Link length
1.3.6.1.4.1.4756.20.210.20.1.33Columnf3R10GFx1DDLenUnitread-onlycurrentLocal FRM220-3R10G card fiber D/D information: Length Unit
1.3.6.1.4.1.4756.20.210.20.1.34Columnf3R10GFx1DDStatusread-onlycurrentLocal FRM220-3R10G card fiber D/D information: Status Support
1.3.6.1.4.1.4756.20.210.20.1.35Columnf3R10GFx1DDRxSensread-onlycurrentLocal FRM220-3R10G card fiber D/D information: Rx Sensitivity
1.3.6.1.4.1.4756.20.210.20.1.36Columnf3R10GFx1DDTxPWRread-onlycurrentLocal FRM220-3R10G card fiber D/D information: Tx power
1.3.6.1.4.1.4756.20.210.20.1.37Columnf3R10GFx1DDRxPWRread-onlycurrentLocal FRM220-3R10G card fiber D/D information: Rx power
1.3.6.1.4.1.4756.20.210.20.1.38Columnf3R10GFx1DDTempread-onlycurrentLocal FRM220-3R10G card fiber D/D information: Temperature in degree C
1.3.6.1.4.1.4756.20.210.20.1.39Columnf3R10GFx1DDPWRMarginread-onlycurrentLocal FRM220-3R10G card fiber D/D information: Power margin
1.3.6.1.4.1.4756.20.210.20.1.40Columnf3R10GFx2DDread-onlycurrentLocal FRM220-3R10G card fiber2 Digital Diagnostic function: 0:No 1:Yes
1.3.6.1.4.1.4756.20.210.20.1.41Columnf3R10GFx2DDVendorread-onlycurrentLocal FRM220-3R10G card fiber2 D/D information: Vendor name
1.3.6.1.4.1.4756.20.210.20.1.42Columnf3R10GFx2DDPartNoread-onlycurrentLocal FRM220-3R10G card fiber2 D/D information: Vendor part number
1.3.6.1.4.1.4756.20.210.20.1.43Columnf3R10GFx2DDFiberTyperead-onlycurrentLocal FRM220-3R10G card fiber2 D/D information: Fiber Type
1.3.6.1.4.1.4756.20.210.20.1.44Columnf3R10GFx2DDWaveLenread-onlycurrentLocal FRM220-3R10G card fiber2 D/D information: Wave length
1.3.6.1.4.1.4756.20.210.20.1.45Columnf3R10GFx2DDWaveLen2read-onlycurrentLocal FRM220-3R10G card fiber2 D/D information: Wave length 2
1.3.6.1.4.1.4756.20.210.20.1.46Columnf3R10GFx2DDLinkLenread-onlycurrentLocal FRM220-3R10G card fiber2 D/D information: Link length
1.3.6.1.4.1.4756.20.210.20.1.47Columnf3R10GFx2DDLenUnitread-onlycurrentLocal FRM220-3R10G card fiber2 D/D information: Length Unit
1.3.6.1.4.1.4756.20.210.20.1.48Columnf3R10GFx2DDStatusread-onlycurrentLocal FRM220-3R10G card fiber2 D/D information: Status Support
1.3.6.1.4.1.4756.20.210.20.1.49Columnf3R10GFx2DDRxSensread-onlycurrentLocal FRM220-3R10G card fiber2 D/D information: Rx Sensitivity
1.3.6.1.4.1.4756.20.210.20.1.50Columnf3R10GFx2DDTxPWRread-onlycurrentLocal FRM220-3R10G card fiber2 D/D information: Tx power
1.3.6.1.4.1.4756.20.210.20.1.51Columnf3R10GFx2DDRxPWRread-onlycurrentLocal FRM220-3R10G card fiber2 D/D information: Rx power
1.3.6.1.4.1.4756.20.210.20.1.52Columnf3R10GFx2DDTempread-onlycurrentLocal FRM220-3R10G card fiber2 D/D information: Temperature in degree C
1.3.6.1.4.1.4756.20.210.20.1.53Columnf3R10GFx2DDPWRMarginread-onlycurrentLocal FRM220-3R10G card fiber2 D/D information: Power margin
1.3.6.1.4.1.4756.20.220NodefE1DATALocalCards
1.3.6.1.4.1.4756.20.220.20TablefE1DATALocalTablenot-accessiblecurrentA list of local FRM220-E1/DATA series card entries. The number of entries is fE1DATA-No-L.
1.3.6.1.4.1.4756.20.220.20.1RowfE1DATALocalEntrynot-accessiblecurrentAn entry containing management information applicable to a particular local FRM220-E1/DATA series card.
1.3.6.1.4.1.4756.20.220.20.1.1ColumnfE1DATAChassisIndexLocalread-onlycurrentA unique value for each local card. It is the chassis location number.
1.3.6.1.4.1.4756.20.220.20.1.2ColumnfE1DATASlotIndexLocalread-onlycurrentA unique value for each local card. It is the slot location number.
1.3.6.1.4.1.4756.20.220.20.1.3ColumnfE1DATACardHWVerLocalread-onlycurrentLocal FRM220-E1DATA Series card hardware version x.xxx
1.3.6.1.4.1.4756.20.220.20.1.4ColumnfE1DATACardFWVerLocalread-onlycurrentLocal FRM220-E1DATA Series card firmware version x.xxx
1.3.6.1.4.1.4756.20.220.20.1.5ColumnfE1DATACardCPLDVerLocalread-onlycurrentLocal FRM220-E1DATA Series card CPLD version x.xxx
1.3.6.1.4.1.4756.20.220.20.1.6ColumnfE1DATACardFPGAVerLocalread-onlycurrentLocal FRM220-E1DATA Series card FPGA version x.xxx
1.3.6.1.4.1.4756.20.220.20.1.7ColumnfE1DATAPortActiveLocalread-writecurrentLocal FRM220-E1DATA Series card active: 0:Disable 1:Enable
1.3.6.1.4.1.4756.20.220.20.1.8ColumnfE1DATAPortResetLocalread-writecurrentLocal FRM220-E1DATA Series card portreset: 0:OFF 1:Action
1.3.6.1.4.1.4756.20.220.20.1.9ColumnfE1DATASettoDefaultLocalread-writecurrentLocal FRM220-E1DATA Series card set to default: 0:OFF 1:Action
1.3.6.1.4.1.4756.20.220.20.1.10ColumnfE1DATASignalLocalread-onlycurrentLocal FRM220-E1DATA Series card E1 signal status: 0:Signal Loss 1:Normal
1.3.6.1.4.1.4756.20.220.20.1.11ColumnfE1DATASyncLocalread-onlycurrentLocal FRM220-E1DATA Series card E1 sync status: 0:Sync Loss 1:Normal
1.3.6.1.4.1.4756.20.220.20.1.12ColumnfE1DATAReAisLocalread-onlycurrentLocal FRM220-E1DATA Series card E1 receive AIS: 0:NO 1:Have
1.3.6.1.4.1.4756.20.220.20.1.13ColumnfE1DATAE1AlarmLocalread-onlycurrentLocal FRM220-E1DATA Series card E1 alarm: 0:NO 1:Have
1.3.6.1.4.1.4756.20.220.20.1.14ColumnfE1DATALOMFLocalread-onlycurrentLocal FRM220-E1DATA Series card E1 loss of multiframe sync: 0:NO 1:Have
1.3.6.1.4.1.4756.20.220.20.1.15ColumnfE1DATALinecodeViolationLocalread-onlycurrentLocal FRM220-E1DATA Series card E1 line code violation: 0:NO 1:Have
1.3.6.1.4.1.4756.20.220.20.1.16ColumnfE1DATAConnectorLocalread-onlycurrentLocal FRM220-E1DATA Series card connector type: 0:BNC 1:RJ-48C
1.3.6.1.4.1.4756.20.220.20.1.17ColumnfE1DATARdSTSLocalread-onlycurrentLocal FRM220-E1DATA Series card RD status: 0:ON 1:OFF 2:Flash
1.3.6.1.4.1.4756.20.220.20.1.18ColumnfE1DATATdSTSLocalread-onlycurrentLocal FRM220-E1DATA Series card TD status: 0:ON 1:OFF 2:Flash
1.3.6.1.4.1.4756.20.220.20.1.19ColumnfE1DATARtsSTSLocalread-onlycurrentLocal FRM220-E1DATA Series card RTS status: 0:On 1:Off
1.3.6.1.4.1.4756.20.220.20.1.20ColumnfE1DATACtsSTSLocalread-onlycurrentLocal FRM220-E1DATA Series card CTS status: 0:On 1:Off
1.3.6.1.4.1.4756.20.220.20.1.21ColumnfE1DATADcdSTSLocalread-onlycurrentLocal FRM220-E1DATA Series card DCD status: 0:On 1:Off
1.3.6.1.4.1.4756.20.220.20.1.22ColumnfE1DATADsrSTSLocalread-onlycurrentLocal FRM220-E1DATA Series card DSR status: 0:On 1:Off
1.3.6.1.4.1.4756.20.220.20.1.23ColumnfE1DATADtrSTSLocalread-onlycurrentLocal FRM220-E1DATA Series card DTR status: 0:On 1:Off
1.3.6.1.4.1.4756.20.220.20.1.24ColumnfE1DATARemoPwAbLocalread-onlycurrentLocal FRM220-E1DATA Series card remote power fail : 0:Normal 1:Fail
1.3.6.1.4.1.4756.20.220.20.1.25ColumnfE1DATABertErrLocalread-onlycurrentLocal FRM220-E1DATA Series card bert error : 0:No error 1:Have error
1.3.6.1.4.1.4756.20.220.20.1.26ColumnfE1DATACableAdaptedSTSLocalread-onlycurrentLocal FRM220-E1DATA Series card cable adapted status: 4:RS-530 DTE 5:RS-530 DCE 6:X.21 DTE 7:X.21 DCE 8:V.35 DTE 9:V.35 DCE 10:RS-499 DTE 11:RS-449 DCE 12:RS-2…
1.3.6.1.4.1.4756.20.220.20.1.27ColumnfE1DATAFrameLocalread-writecurrentLocal FRM220-E1DATA Series card frame mode: 0:Unframed 1:Framed
1.3.6.1.4.1.4756.20.220.20.1.28ColumnfE1DATATimeSlot1Localread-writecurrentLocal FRM220-E1DATA Series card timeslot1: 0:Inactive 1:Active
1.3.6.1.4.1.4756.20.220.20.1.29ColumnfE1DATATimeSlot2Localread-writecurrentLocal FRM220-E1DATA Series card timeslot2: 0:Inactive 1:Active
1.3.6.1.4.1.4756.20.220.20.1.30ColumnfE1DATATimeSlot3Localread-writecurrentLocal FRM220-E1DATA Series card timeslot3: 0:Inactive 1:Active
1.3.6.1.4.1.4756.20.220.20.1.31ColumnfE1DATATimeSlot4Localread-writecurrentLocal FRM220-E1DATA Series card timeslot4: 0:Inactive 1:Active
1.3.6.1.4.1.4756.20.220.20.1.32ColumnfE1DATATimeSlot5Localread-writecurrentLocal FRM220-E1DATA Series card timeslot5: 0:Inactive 1:Active
1.3.6.1.4.1.4756.20.220.20.1.33ColumnfE1DATATimeSlot6Localread-writecurrentLocal FRM220-E1DATA Series card timeslot6: 0:Inactive 1:Active
1.3.6.1.4.1.4756.20.220.20.1.34ColumnfE1DATATimeSlot7Localread-writecurrentLocal FRM220-E1DATA Series card timeslot7: 0:Inactive 1:Active
1.3.6.1.4.1.4756.20.220.20.1.35ColumnfE1DATATimeSlot8Localread-writecurrentLocal FRM220-E1DATA Series card timeslot8: 0:Inactive 1:Active
1.3.6.1.4.1.4756.20.220.20.1.36ColumnfE1DATATimeSlot9Localread-writecurrentLocal FRM220-E1DATA Series card timeslot9: 0:Inactive 1:Active
1.3.6.1.4.1.4756.20.220.20.1.37ColumnfE1DATATimeSlot10Localread-writecurrentLocal FRM220-E1DATA Series card timeslot10: 0:Inactive 1:Active
1.3.6.1.4.1.4756.20.220.20.1.38ColumnfE1DATATimeSlot11Localread-writecurrentLocal FRM220-E1DATA Series card timeslot11: 0:Inactive 1:Active
1.3.6.1.4.1.4756.20.220.20.1.39ColumnfE1DATATimeSlot12Localread-writecurrentLocal FRM220-E1DATA Series card timeslot12: 0:Inactive 1:Active
1.3.6.1.4.1.4756.20.220.20.1.40ColumnfE1DATATimeSlot13Localread-writecurrentLocal FRM220-E1DATA Series card timeslot13: 0:Inactive 1:Active
1.3.6.1.4.1.4756.20.220.20.1.41ColumnfE1DATATimeSlot14Localread-writecurrentLocal FRM220-E1DATA Series card timeslot14: 0:Inactive 1:Active
1.3.6.1.4.1.4756.20.220.20.1.42ColumnfE1DATATimeSlot15Localread-writecurrentLocal FRM220-E1 Series card timeslot15: 0:Inactive 1:Active
1.3.6.1.4.1.4756.20.220.20.1.43ColumnfE1DATATimeSlot16Localread-writecurrentLocal FRM220-E1 Series card timeslot16: 0:Inactive 1:Active
1.3.6.1.4.1.4756.20.220.20.1.44ColumnfE1DATATimeSlot17Localread-writecurrentLocal FRM220-E1DATA Series card timeslot17: 0:Inactive 1:Active
1.3.6.1.4.1.4756.20.220.20.1.45ColumnfE1DATATimeSlot18Localread-writecurrentLocal FRM220-E1DATA Series card timeslot18: 0:Inactive 1:Active
1.3.6.1.4.1.4756.20.220.20.1.46ColumnfE1DATATimeSlot19Localread-writecurrentLocal FRM220-E1DATA Series card timeslot19: 0:Inactive 1:Active
1.3.6.1.4.1.4756.20.220.20.1.47ColumnfE1DATATimeSlot20Localread-writecurrentLocal FRM220-E1DATA Series card timeslot20: 0:Inactive 1:Active
1.3.6.1.4.1.4756.20.220.20.1.48ColumnfE1DATATimeSlot21Localread-writecurrentLocal FRM220-E1DATA Series card timeslot21: 0:Inactive 1:Active
1.3.6.1.4.1.4756.20.220.20.1.49ColumnfE1DATATimeSlot22Localread-writecurrentLocal FRM220-E1DATA Series card timeslot22: 0:Inactive 1:Active
1.3.6.1.4.1.4756.20.220.20.1.50ColumnfE1DATATimeSlot23Localread-writecurrentLocal FRM220-E1DATA Series card timeslot23: 0:Inactive 1:Active
1.3.6.1.4.1.4756.20.220.20.1.51ColumnfE1DATATimeSlot24Localread-writecurrentLocal FRM220-E1DATA Series card timeslot24: 0:Inactive 1:Active
1.3.6.1.4.1.4756.20.220.20.1.52ColumnfE1DATATimeSlot25Localread-writecurrentLocal FRM220-E1DATA Series card timeslot25: 0:Inactive 1:Active
1.3.6.1.4.1.4756.20.220.20.1.53ColumnfE1DATATimeSlot26Localread-writecurrentLocal FRM220-E1DATA Series card timeslot26: 0:Inactive 1:Active
1.3.6.1.4.1.4756.20.220.20.1.54ColumnfE1DATATimeSlot27Localread-writecurrentLocal FRM220-E1DATA Series card timeslot27: 0:Inactive 1:Active
1.3.6.1.4.1.4756.20.220.20.1.55ColumnfE1DATATimeSlot28Localread-writecurrentLocal FRM220-E1DATA Series card timeslot28: 0:Inactive 1:Active
1.3.6.1.4.1.4756.20.220.20.1.56ColumnfE1DATATimeSlot29Localread-writecurrentLocal FRM220-E1DATA Series card timeslot29: 0:Inactive 1:Active
1.3.6.1.4.1.4756.20.220.20.1.57ColumnfE1DATATimeSlot30Localread-writecurrentLocal FRM220-E1DATA Series card timeslot30: 0:Inactive 1:Active
1.3.6.1.4.1.4756.20.220.20.1.58ColumnfE1DATATimeSlot31Localread-writecurrentLocal FRM220-E1DATA Series card timeslot31: 0:Inactive 1:Active
1.3.6.1.4.1.4756.20.220.20.1.59ColumnfE1DATATimeSourceLocalread-writecurrentLocal FRM220-E1DATA Series card time souce: 0:Recovery from E1 1:Data port 2:Internal oscillator 3:Transparent
1.3.6.1.4.1.4756.20.220.20.1.60ColumnfE1DATARcPolarityLocalread-writecurrentLocal FRM220-E1DATA Series card RC polarity: 0:Normal 1:Invert
1.3.6.1.4.1.4756.20.220.20.1.61ColumnfE1DATATcPolarityLocalread-writecurrentLocal FRM220-E1DATA Series card TC polarity: 0:Normal 1:Invert
1.3.6.1.4.1.4756.20.220.20.1.62ColumnfE1DATAEtcPolarityLocalread-writecurrentLocal FRM220-E1DATA Series card ETC polarity: 0:Normal 1:Invert
1.3.6.1.4.1.4756.20.220.20.1.63ColumnfE1DATALinecodeLocalread-writecurrentLocal FRM220-E1DATA Series card line code: 0:HDB3 1:AMI
1.3.6.1.4.1.4756.20.220.20.1.64ColumnfE1DATAFramerLocalread-writecurrentLocal FRM220-E1DATA Series card framer mode: 0:CCS 1:CAS
1.3.6.1.4.1.4756.20.220.20.1.65ColumnfE1DATAAisLocalread-writecurrentLocal FRM220-E1DATA Series card AIS: 0:Disable 1:Enable
1.3.6.1.4.1.4756.20.220.20.1.66ColumnfE1DATADataPortTypeLocalread-writecurrentLocal FRM220-E1DATA Series card Data port type: 0:Cable adapted 1:V.35 2:RS 530 3:X.21 4:RS 232 5:RS 449
1.3.6.1.4.1.4756.20.220.20.1.67ColumnfE1DATADteDceLocalread-writecurrentLocal FRM220-E1DATA Series card DCE/DTE mode: 0:DCE 1:DTE
1.3.6.1.4.1.4756.20.220.20.1.68ColumnfE1DATADataPortServiceLocalread-writecurrentLocal FRM220-E1DATA Series card Data port service: 0:Enable 1:Disable
1.3.6.1.4.1.4756.20.220.20.1.69ColumnfE1DATALbsettingLocalread-writecurrentLocal FRM220-E1DATA Series card Loop back test: 0:Off 1:LLB 2:RLB 3:RRLB
1.3.6.1.4.1.4756.20.220.20.1.70ColumnfE1DATALbsettingSelLocalread-writecurrentLocal FRM220-E1DATA Series card Loop back select: 0:E1 side 1:Data port side
1.3.6.1.4.1.4756.20.220.20.1.71ColumnfE1DATABertLocalread-writecurrentLocal FRM220-E1DATA Series card bert mode: 0:Disable 1:Enable
1.3.6.1.4.1.4756.20.220.20.1.72ColumnfE1DATAUnusedTimeslotLocalread-writecurrentLocal FRM220-E1DATA Series unsued time slot: 0:0X7E 1:0XFF
1.3.6.1.4.1.4756.20.220.20.1.73ColumnfE1DATACtsRtsLocalread-writecurrentLocal FRM220-E1DATA Series : 0:Follows RTS/CTS 1:Constantly on
1.3.6.1.4.1.4756.20.220.20.1.74ColumnfE1DATADsrDtrLocalread-writecurrentLocal FRM220-E1DATA Series unsued time slot: 0:Follows DSR/DTR 1:Constantly on
1.3.6.1.4.1.4756.20.220.20.1.75ColumnfE1DATATestSTSLocalread-writecurrentLocal FRM220-E1DATA Series test status: 0:Normal 1:In test
1.3.6.1.4.1.4756.20.220.20.1.76ColumnfE1DATADataportLLBLocalread-writecurrentLocal FRM220-E1DATA Series Dataport LLB Mode: 0:Disable 1:Enable
1.3.6.1.4.1.4756.20.220.20.1.77ColumnfE1DATARateLocalread-onlycurrentLocal FRM220-E1DATA rate
1.3.6.1.4.1.4756.20.220.20.1.78ColumnfE1DATADataportWorkModeLocalread-writecurrentLocal FRM220-E1DATA Series Dataport Work Mode: 0:Synchronous 1:Asynchronous
1.3.6.1.4.1.4756.20.221NodefE1DATARemoteCards
1.3.6.1.4.1.4756.20.221.20TablefE1DATARemoteTablenot-accessiblecurrentA list of Remote FRM220-E1/DATA series card entries. The number of entries is fE1DATA-No-R.
1.3.6.1.4.1.4756.20.221.20.1RowfE1DATARemoteEntrynot-accessiblecurrentAn entry containing management information applicable to a particular Remote FRM220-E1/DATA series card.
1.3.6.1.4.1.4756.20.221.20.1.1ColumnfE1DATAChassisIndexRemoteread-onlycurrentA unique value for each Remote card. It is the chassis location number.
1.3.6.1.4.1.4756.20.221.20.1.2ColumnfE1DATASlotIndexRemoteread-onlycurrentA unique value for each Remote card. It is the slot location number.
1.3.6.1.4.1.4756.20.221.20.1.3ColumnfE1DATACardHWVerRemoteread-onlycurrentRemote FRM220-E1DATA Series card hardware version x.xxx
1.3.6.1.4.1.4756.20.221.20.1.4ColumnfE1DATACardFWVerRemoteread-onlycurrentRemote FRM220-E1DATA Series card firmware version x.xxx
1.3.6.1.4.1.4756.20.221.20.1.5ColumnfE1DATACardCPLDVerRemoteread-onlycurrentRemote FRM220-E1DATA Series card CPLD version x.xxx
1.3.6.1.4.1.4756.20.221.20.1.6ColumnfE1DATACardFPGAVerRemoteread-onlycurrentRemote FRM220-E1DATA Series card FPGA version x.xxx
1.3.6.1.4.1.4756.20.221.20.1.7ColumnfE1DATAPortActiveRemoteread-onlycurrentRemote FRM220-E1DATA Series card active: 0:Disable 1:Enable
1.3.6.1.4.1.4756.20.221.20.1.8ColumnfE1DATAPortResetRemoteread-writecurrentRemote FRM220-E1DATA Series card portreset: 0:OFF 1:Action
1.3.6.1.4.1.4756.20.221.20.1.9ColumnfE1DATASettoDefaultRemoteread-writecurrentRemote FRM220-E1DATA Series card set to default: 0:OFF 1:Action
1.3.6.1.4.1.4756.20.221.20.1.10ColumnfE1DATASignalRemoteread-onlycurrentRemote FRM220-E1DATA Series card E1 signal status: 0:Signal Loss 1:Normal
1.3.6.1.4.1.4756.20.221.20.1.11ColumnfE1DATASyncRemoteread-onlycurrentRemote FRM220-E1DATA Series card E1 sync status: 0:Sync Loss 1:Normal
1.3.6.1.4.1.4756.20.221.20.1.12ColumnfE1DATAReAisRemoteread-onlycurrentRemote FRM220-E1DATA Series card E1 receive AIS: 0:NO 1:Have
1.3.6.1.4.1.4756.20.221.20.1.13ColumnfE1DATAE1AlarmRemoteread-onlycurrentRemote FRM220-E1DATA Series card E1 alarm: 0:NO 1:Have
1.3.6.1.4.1.4756.20.221.20.1.14ColumnfE1DATALOMFRemoteread-onlycurrentRemote FRM220-E1DATA Series card E1 loss of multiframe sync: 0:NO 1:Have
1.3.6.1.4.1.4756.20.221.20.1.15ColumnfE1DATALinecodeViolationRemoteread-onlycurrentRemote FRM220-E1DATA Series card E1 line code violation: 0:NO 1:Have
1.3.6.1.4.1.4756.20.221.20.1.16ColumnfE1DATAConnectorRemoteread-onlycurrentRemote FRM220-E1DATA Series card connector type: 0:BNC 1:RJ-48C
1.3.6.1.4.1.4756.20.221.20.1.17ColumnfE1DATARdSTSRemoteread-onlycurrentRemote FRM220-E1DATA Series card RD status: 0:ON 1:OFF 2:Flash
1.3.6.1.4.1.4756.20.221.20.1.18ColumnfE1DATATdSTSRemoteread-onlycurrentRemote FRM220-E1DATA Series card TD status: 0:ON 1:OFF 2:Flash
1.3.6.1.4.1.4756.20.221.20.1.19ColumnfE1DATARtsSTSRemoteread-onlycurrentRemote FRM220-E1DATA Series card RTS status: 0:ON 1:OFF
1.3.6.1.4.1.4756.20.221.20.1.20ColumnfE1DATACtsSTSRemoteread-onlycurrentRemote FRM220-E1DATA Series card CTS status: 0:On 1:Off
1.3.6.1.4.1.4756.20.221.20.1.21ColumnfE1DATADcdSTSRemoteread-onlycurrentRemote FRM220-E1DATA Series card DCD status: 0:On 1:Off
1.3.6.1.4.1.4756.20.221.20.1.22ColumnfE1DATADsrSTSRemoteread-onlycurrentRemote FRM220-E1DATA Series card DSR status: 0:On 1:Off
1.3.6.1.4.1.4756.20.221.20.1.23ColumnfE1DATADtrSTSRemoteread-onlycurrentRemote FRM220-E1DATA Series card DTR status: 0:On 1:Off
1.3.6.1.4.1.4756.20.221.20.1.24ColumnfE1DATARemoPwAbRemoteread-onlycurrentRemote FRM220-E1DATA Series card remote power fail : 0:Normal 1:Fail
1.3.6.1.4.1.4756.20.221.20.1.25ColumnfE1DATABertErrRemoteread-onlycurrentRemote FRM220-E1DATA Series card bert error : 0:No error 1:Have error
1.3.6.1.4.1.4756.20.221.20.1.26ColumnfE1DATACableAdaptedSTSRemoteread-onlycurrentRemote FRM220-E1DATA Series card cable adapted status: 4:RS-530 DTE 5:RS-530 DCE 6:X.21 DTE 7:X.21 DCE 8:V.35 DTE 9:V.35 DCE 10:RS-499 DTE 11:RS-449 DCE 12:RS-…
1.3.6.1.4.1.4756.20.221.20.1.27ColumnfE1DATAFrameRemoteread-writecurrentRemote FRM220-E1DATA Series card frame mode: 0:Unframed 1:Framed
1.3.6.1.4.1.4756.20.221.20.1.28ColumnfE1DATATimeSlot1Remoteread-writecurrentRemote FRM220-E1DATA Series card timeslot1: 0:Inactive 1:Active
1.3.6.1.4.1.4756.20.221.20.1.29ColumnfE1DATATimeSlot2Remoteread-writecurrentRemote FRM220-E1DATA Series card timeslot2: 0:Inactive 1:Active
1.3.6.1.4.1.4756.20.221.20.1.30ColumnfE1DATATimeSlot3Remoteread-writecurrentRemote FRM220-E1DATA Series card timeslot3: 0:Inactive 1:Active
1.3.6.1.4.1.4756.20.221.20.1.31ColumnfE1DATATimeSlot4Remoteread-writecurrentRemote FRM220-E1DATA Series card timeslot4: 0:Inactive 1:Active
1.3.6.1.4.1.4756.20.221.20.1.32ColumnfE1DATATimeSlot5Remoteread-writecurrentRemote FRM220-E1DATA Series card timeslot5: 0:Inactive 1:Active
1.3.6.1.4.1.4756.20.221.20.1.33ColumnfE1DATATimeSlot6Remoteread-writecurrentRemote FRM220-E1DATA Series card timeslot6: 0:Inactive 1:Active
1.3.6.1.4.1.4756.20.221.20.1.34ColumnfE1DATATimeSlot7Remoteread-writecurrentRemote FRM220-E1DATA Series card timeslot7: 0:Inactive 1:Active
1.3.6.1.4.1.4756.20.221.20.1.35ColumnfE1DATATimeSlot8Remoteread-writecurrentRemote FRM220-E1DATA Series card timeslot8: 0:Inactive 1:Active
1.3.6.1.4.1.4756.20.221.20.1.36ColumnfE1DATATimeSlot9Remoteread-writecurrentRemote FRM220-E1DATA Series card timeslot9: 0:Inactive 1:Active
1.3.6.1.4.1.4756.20.221.20.1.37ColumnfE1DATATimeSlot10Remoteread-writecurrentRemote FRM220-E1DATA Series card timeslot10: 0:Inactive 1:Active
1.3.6.1.4.1.4756.20.221.20.1.38ColumnfE1DATATimeSlot11Remoteread-writecurrentRemote FRM220-E1DATA Series card timeslot11: 0:Inactive 1:Active
1.3.6.1.4.1.4756.20.221.20.1.39ColumnfE1DATATimeSlot12Remoteread-writecurrentRemote FRM220-E1DATA Series card timeslot12: 0:Inactive 1:Active
1.3.6.1.4.1.4756.20.221.20.1.40ColumnfE1DATATimeSlot13Remoteread-writecurrentRemote FRM220-E1DATA Series card timeslot13: 0:Inactive 1:Active
1.3.6.1.4.1.4756.20.221.20.1.41ColumnfE1DATATimeSlot14Remoteread-writecurrentRemote FRM220-E1DATA Series card timeslot14: 0:Inactive 1:Active
1.3.6.1.4.1.4756.20.221.20.1.42ColumnfE1DATATimeSlot15Remoteread-writecurrentRemote FRM220-E1 Series card timeslot15: 0:Inactive 1:Active
1.3.6.1.4.1.4756.20.221.20.1.43ColumnfE1DATATimeSlot16Remoteread-writecurrentRemote FRM220-E1 Series card timeslot16: 0:Inactive 1:Active
1.3.6.1.4.1.4756.20.221.20.1.44ColumnfE1DATATimeSlot17Remoteread-writecurrentRemote FRM220-E1DATA Series card timeslot17: 0:Inactive 1:Active
1.3.6.1.4.1.4756.20.221.20.1.45ColumnfE1DATATimeSlot18Remoteread-writecurrentRemote FRM220-E1DATA Series card timeslot18: 0:Inactive 1:Active
1.3.6.1.4.1.4756.20.221.20.1.46ColumnfE1DATATimeSlot19Remoteread-writecurrentRemote FRM220-E1DATA Series card timeslot19: 0:Inactive 1:Active
1.3.6.1.4.1.4756.20.221.20.1.47ColumnfE1DATATimeSlot20Remoteread-writecurrentRemote FRM220-E1DATA Series card timeslot20: 0:Inactive 1:Active
1.3.6.1.4.1.4756.20.221.20.1.48ColumnfE1DATATimeSlot21Remoteread-writecurrentRemote FRM220-E1DATA Series card timeslot21: 0:Inactive 1:Active
1.3.6.1.4.1.4756.20.221.20.1.49ColumnfE1DATATimeSlot22Remoteread-writecurrentRemote FRM220-E1DATA Series card timeslot22: 0:Inactive 1:Active
1.3.6.1.4.1.4756.20.221.20.1.50ColumnfE1DATATimeSlot23Remoteread-writecurrentRemote FRM220-E1DATA Series card timeslot23: 0:Inactive 1:Active
1.3.6.1.4.1.4756.20.221.20.1.51ColumnfE1DATATimeSlot24Remoteread-writecurrentRemote FRM220-E1DATA Series card timeslot24: 0:Inactive 1:Active
1.3.6.1.4.1.4756.20.221.20.1.52ColumnfE1DATATimeSlot25Remoteread-writecurrentRemote FRM220-E1DATA Series card timeslot25: 0:Inactive 1:Active
1.3.6.1.4.1.4756.20.221.20.1.53ColumnfE1DATATimeSlot26Remoteread-writecurrentRemote FRM220-E1DATA Series card timeslot26: 0:Inactive 1:Active
1.3.6.1.4.1.4756.20.221.20.1.54ColumnfE1DATATimeSlot27Remoteread-writecurrentRemote FRM220-E1DATA Series card timeslot27: 0:Inactive 1:Active
1.3.6.1.4.1.4756.20.221.20.1.55ColumnfE1DATATimeSlot28Remoteread-writecurrentRemote FRM220-E1DATA Series card timeslot28: 0:Inactive 1:Active
1.3.6.1.4.1.4756.20.221.20.1.56ColumnfE1DATATimeSlot29Remoteread-writecurrentRemote FRM220-E1DATA Series card timeslot29: 0:Inactive 1:Active
1.3.6.1.4.1.4756.20.221.20.1.57ColumnfE1DATATimeSlot30Remoteread-writecurrentRemote FRM220-E1DATA Series card timeslot30: 0:Inactive 1:Active
1.3.6.1.4.1.4756.20.221.20.1.58ColumnfE1DATATimeSlot31Remoteread-writecurrentRemote FRM220-E1DATA Series card timeslot31: 0:Inactive 1:Active
1.3.6.1.4.1.4756.20.221.20.1.59ColumnfE1DATATimeSourceRemoteread-writecurrentRemote FRM220-E1DATA Series card time souce: 0:Recovery from E1 1:Data port 2:Internal oscillator 3:Transparent
1.3.6.1.4.1.4756.20.221.20.1.60ColumnfE1DATARcPolarityRemoteread-writecurrentRemote FRM220-E1DATA Series card RC polarity: 0:Normal 1:Invert
1.3.6.1.4.1.4756.20.221.20.1.61ColumnfE1DATATcPolarityRemoteread-writecurrentRemote FRM220-E1DATA Series card TC polarity: 0:Normal 1:Invert
1.3.6.1.4.1.4756.20.221.20.1.62ColumnfE1DATAEtcPolarityRemoteread-writecurrentRemote FRM220-E1DATA Series card ETC polarity: 0:Normal 1:Invert
1.3.6.1.4.1.4756.20.221.20.1.63ColumnfE1DATALinecodeRemoteread-writecurrentRemote FRM220-E1DATA Series card line code: 0:HDB3 1:AMI
1.3.6.1.4.1.4756.20.221.20.1.64ColumnfE1DATAFramerRemoteread-writecurrentRemote FRM220-E1DATA Series card framer mode: 0:CCS 1:CAS
1.3.6.1.4.1.4756.20.221.20.1.65ColumnfE1DATAAisRemoteread-writecurrentRemote FRM220-E1DATA Series card AIS: 0:Disable 1:Enable
1.3.6.1.4.1.4756.20.221.20.1.66ColumnfE1DATADataPortTypeRemoteread-writecurrentRemote FRM220-E1DATA Series card Data port type: 0:Cable adapted 1:V.35 2:RS 530 3:X.21 4:RS 232 5:RS 449
1.3.6.1.4.1.4756.20.221.20.1.67ColumnfE1DATADteDceRemoteread-writecurrentRemote FRM220-E1DATA Series card DCE/DTE mode: 0:DCE 1:DTE
1.3.6.1.4.1.4756.20.221.20.1.68ColumnfE1DATADataPortServiceRemoteread-writecurrentRemote FRM220-E1DATA Series card Data port service: 0:Enable 1:Disable
1.3.6.1.4.1.4756.20.221.20.1.69ColumnfE1DATABertRemoteread-writecurrentRemote FRM220-E1DATA Series card bert mode: 0:Disable 1:Enable
1.3.6.1.4.1.4756.20.221.20.1.70ColumnfE1DATAUnusedTimeslotRemoteread-writecurrentRemote FRM220-E1DATA Series unsued time slot: 0:0X7E 1:0XFF
1.3.6.1.4.1.4756.20.221.20.1.71ColumnfE1DATACtsRtsRemoteread-writecurrentRemote FRM220-E1DATA Series : 0:Follows RTS/CTS 1:Constantly on
1.3.6.1.4.1.4756.20.221.20.1.72ColumnfE1DATADsrDtrRemoteread-writecurrentRemote FRM220-E1DATA Series unsued time slot: 0:Follows DSR/DTR 1:Constantly on
1.3.6.1.4.1.4756.20.221.20.1.73ColumnfE1DATATestSTSRemoteread-writecurrentRemote FRM220-E1DATA Series test status: 0:Normal 1:In test
1.3.6.1.4.1.4756.20.221.20.1.74ColumnfE1DATADataportLLBRemoteread-writecurrentRemote FRM220-E1DATA Series Dataport LLB Mode: 0:Disable 1:Enable
1.3.6.1.4.1.4756.20.221.20.1.75ColumnfE1DATARateRemoteread-onlycurrentRemote FRM220-E1DATA rate
1.3.6.1.4.1.4756.20.221.20.1.76ColumnfE1DATADataportWorkModeRemoteread-writecurrentRemote FRM220-E1DATA Series Dataport Work Mode: 0:Synchronous 1:Asynchronous
1.3.6.1.4.1.4756.20.240NodefTECCards
1.3.6.1.4.1.4756.20.240.20TablefTECTablenot-accessiblecurrentA list of local FRM220-FTEC card entries. The number of entries is FTEC cards.
1.3.6.1.4.1.4756.20.240.20.1RowfTECEntrynot-accessiblecurrentAn entry containing management information applicable to a particular local FRM220-FTEC card.
1.3.6.1.4.1.4756.20.240.20.1.1ColumnfTECChassisIndexread-onlycurrentA unique value for each local card. It is the chassis location number.
1.3.6.1.4.1.4756.20.240.20.1.2ColumnfTECSlotIndexread-onlycurrentA unique value for each local card. It is the slot location number.
1.3.6.1.4.1.4756.20.240.20.1.3ColumnfTECCardHWVerread-onlycurrentLocal FRM220-FTEC card hardware version x.xxx
1.3.6.1.4.1.4756.20.240.20.1.4ColumnfTECCardFWVerread-onlycurrentLocal FRM220-FTEC card firmware version x.xxx
1.3.6.1.4.1.4756.20.240.20.1.5ColumnfTECCardCPLDVerread-onlycurrentLocal FRM220-FTEC card CPLD version x.xxx
1.3.6.1.4.1.4756.20.240.20.1.6ColumnfTECCardFPGAVerread-onlycurrentLocal FRM220-FTEC card FPGA version x.xxx
1.3.6.1.4.1.4756.20.240.20.1.7ColumnfTECPortActiveread-writecurrentFRM220-FTEC Card Series card active: 0:Disable 1:Enable
1.3.6.1.4.1.4756.20.240.20.1.8ColumnfTECPortResetread-writecurrentFRM220-FTEC Series card portreset: 0:OFF 1:Action
1.3.6.1.4.1.4756.20.240.20.1.9ColumnfTECSettoDefaultread-writecurrentFRM220-FTEC Series card set to default: 0:OFF 1:Action
1.3.6.1.4.1.4756.20.240.20.1.10ColumnfTECSystemOKSTSread-onlycurrentFRM220-FTEC system ok status 0:Have 1:No
1.3.6.1.4.1.4756.20.240.20.1.11ColumnfTECTestSTSread-onlycurrentFRM220-FTEC test status 0:Have 1:No
1.3.6.1.4.1.4756.20.240.20.1.12ColumnfTECE1AlarmSTSread-onlycurrentFRM220-FTEC E1 alarm status 0:Have 1:No
1.3.6.1.4.1.4756.20.240.20.1.13ColumnfTECE1SignalSTSread-onlycurrentFRM220-FTEC E1 signal status 0:Loss 1:Normal
1.3.6.1.4.1.4756.20.240.20.1.14ColumnfTECE1SyncSTSread-onlycurrentFRM220-FTEC E1 sync status 0:Loss 1:Sync
1.3.6.1.4.1.4756.20.240.20.1.15ColumnfTECE1AisSTSread-onlycurrentFRM220-FTEC E1 ais status 0:Have 1:No
1.3.6.1.4.1.4756.20.240.20.1.16ColumnfTECT1AlarmSTSread-onlycurrentFRM220-FTEC T1 alarm status 0:Have 1:No
1.3.6.1.4.1.4756.20.240.20.1.17ColumnfTECT1SignalSTSread-onlycurrentFRM220-FTEC T1 signal status 0:Loss 1:Normal
1.3.6.1.4.1.4756.20.240.20.1.18ColumnfTECT1SyncSTSread-onlycurrentFRM220-FTEC T1 sync status 0:Loss 1:Sync
1.3.6.1.4.1.4756.20.240.20.1.19ColumnfTECT1AisSTSread-onlycurrentFRM220-FTEC T1 ais status
1.3.6.1.4.1.4756.20.240.20.1.20ColumnfTECE1LineCoderead-writecurrentFRM220-FTEC E1 line code: 0:HDB3 1:AMI
1.3.6.1.4.1.4756.20.240.20.1.21ColumnfTECE1Frameread-writecurrentFRM220-FTEC E1 frame formats: 0:CCS 1:CAS
1.3.6.1.4.1.4756.20.240.20.1.22ColumnfTECE1Crc4read-writecurrentFRM220-FTEC E1 crc4: 0:disable 1:enable
1.3.6.1.4.1.4756.20.240.20.1.23ColumnfTECE1LineImpedanceread-writecurrentFRM220-FTEC E1 line impedance: 0:120 ohm 1:75 ohm
1.3.6.1.4.1.4756.20.240.20.1.24ColumnfTECUnUsedTimeslotread-writecurrentFRM220-FTEC unused timeslot: 0:0X7E 1:0XFF
1.3.6.1.4.1.4756.20.240.20.1.25ColumnfTECT1LineBuildread-writecurrentFRM220-FTEC T1 line build-out select: 0:0-133 feet/0dB CSU 1:133-266 feet 2:266-399 feet 3:399-533 feet 4:533-655 feet 5:-7.5dB CSU 6:-15dB CSU 7:-22.5dB CSU
1.3.6.1.4.1.4756.20.240.20.1.26ColumnfTECT1LineCoderead-writecurrentFRM220-FTEC T1 line code: 0:B8ZS 1:AMI
1.3.6.1.4.1.4756.20.240.20.1.27ColumnfTECT1Frameread-writecurrentFRM220-FTEC T1 frame formats: 0:SF(D4) 1:ESF
1.3.6.1.4.1.4756.20.240.20.1.28ColumnfTECTimesourceread-writecurrentFRM220-FTEC timesource: 0:Transparent 1:E1 side recovery 2:T1 side recovery 3:Internal oscillator 4:Loopback
1.3.6.1.4.1.4756.20.240.20.1.29ColumnfTECSignalingmoderead-writecurrentFRM220-FTEC signaling mode: 0:Signaling disable 1:According ABCD 2:T1 E&M signaling to E1 MFC R2 signaling 3:According to signaling table A 4:G.802 Annex B fun…
1.3.6.1.4.1.4756.20.240.20.1.30ColumnfTECSignalingBitAread-writecurrentFRM220-FTEC signaling Bit A: 0:Noe invert 1:Invert 2:Always 0 3:Always 1
1.3.6.1.4.1.4756.20.240.20.1.31ColumnfTECSignalingBitBread-writecurrentFRM220-FTEC signaling Bit B: 0:Not invert 1:Invert 2:Always 0 3:Always 1
1.3.6.1.4.1.4756.20.240.20.1.32ColumnfTECSignalingBitCread-writecurrentFRM220-FTEC signaling Bit C: 0:Not invert 1:Invert 2:Always 0 3:Always 1
1.3.6.1.4.1.4756.20.240.20.1.33ColumnfTECSignalingBitDread-writecurrentFRM220-FTEC signaling Bit D: 0:Not invert 1:Invert 2:Always 0 3:Always 1
1.3.6.1.4.1.4756.20.240.20.1.34ColumnfTECE1Loopbackread-writecurrentFRM220-FTEC E1 loopback: 0:Off 1:LLB 2:RLB
1.3.6.1.4.1.4756.20.240.20.1.35ColumnfTECT1Loopbackread-writecurrentFRM220-FTEC T1 loopback: 0:Off 1:LLB 2:RLB
1.3.6.1.4.1.4756.20.240.20.1.36ColumnfTECFrontpanelLoopbackread-writecurrentFRM220-FTEC front panel loopback: 0:Disable 1:Enable
1.3.6.1.4.1.4756.20.240.20.1.37ColumnfTECE1Timeslot1read-writecurrentFRM220-FTEC E1 timeslot 1: 0:No use 1:used
1.3.6.1.4.1.4756.20.240.20.1.38ColumnfTECE1Timeslot2read-writecurrentFRM220-FTEC E1 timeslot 2: 0:No use 1:used
1.3.6.1.4.1.4756.20.240.20.1.39ColumnfTECE1Timeslot3read-writecurrentFRM220-FTEC E1 timeslot 3: 0:No use 1:used
1.3.6.1.4.1.4756.20.240.20.1.40ColumnfTECE1Timeslot4read-writecurrentFRM220-FTEC E1 timeslot 4: 0:No use 1:used
1.3.6.1.4.1.4756.20.240.20.1.41ColumnfTECE1Timeslot5read-writecurrentFRM220-FTEC E1 timeslot 5: 0:No use 1:used
1.3.6.1.4.1.4756.20.240.20.1.42ColumnfTECE1Timeslot6read-writecurrentFRM220-FTEC E1 timeslot 6: 0:No use 1:used
1.3.6.1.4.1.4756.20.240.20.1.43ColumnfTECE1Timeslot7read-writecurrentFRM220-FTEC E1 timeslot 7: 0:No use 1:used
1.3.6.1.4.1.4756.20.240.20.1.44ColumnfTECE1Timeslot8read-writecurrentFRM220-FTEC E1 timeslot 8: 0:No use 1:used
1.3.6.1.4.1.4756.20.240.20.1.45ColumnfTECE1Timeslot9read-writecurrentFRM220-FTEC E1 timeslot 9: 0:No use 1:used
1.3.6.1.4.1.4756.20.240.20.1.46ColumnfTECE1Timeslot10read-writecurrentFRM220-FTEC E1 timeslot 10: 0:No use 1:used
1.3.6.1.4.1.4756.20.240.20.1.47ColumnfTECE1Timeslot11read-writecurrentFRM220-FTEC E1 timeslot 11: 0:No use 1:used
1.3.6.1.4.1.4756.20.240.20.1.48ColumnfTECE1Timeslot12read-writecurrentFRM220-FTEC E1 timeslot 12: 0:No use 1:used
1.3.6.1.4.1.4756.20.240.20.1.49ColumnfTECE1Timeslot13read-writecurrentFRM220-FTEC E1 timeslot 13: 0:No use 1:used
1.3.6.1.4.1.4756.20.240.20.1.50ColumnfTECE1Timeslot14read-writecurrentFRM220-FTEC E1 timeslot 14: 0:No use 1:used
1.3.6.1.4.1.4756.20.240.20.1.51ColumnfTECE1Timeslot15read-writecurrentFRM220-FTEC E1 timeslot 15: 0:No use 1:used
1.3.6.1.4.1.4756.20.240.20.1.52ColumnfTECE1Timeslot16read-writecurrentFRM220-FTEC E1 timeslot 16: 0:No use 1:used
1.3.6.1.4.1.4756.20.240.20.1.53ColumnfTECE1Timeslot17read-writecurrentFRM220-FTEC E1 timeslot 17: 0:No use 1:used
1.3.6.1.4.1.4756.20.240.20.1.54ColumnfTECE1Timeslot18read-writecurrentFRM220-FTEC E1 timeslot 18: 0:No use 1:used
1.3.6.1.4.1.4756.20.240.20.1.55ColumnfTECE1Timeslot19read-writecurrentFRM220-FTEC E1 timeslot 19: 0:No use 1:used
1.3.6.1.4.1.4756.20.240.20.1.56ColumnfTECE1Timeslot20read-writecurrentFRM220-FTEC E1 timeslot 20: 0:No use 1:used
1.3.6.1.4.1.4756.20.240.20.1.57ColumnfTECE1Timeslot21read-writecurrentFRM220-FTEC E1 timeslot 21: 0:No use 1:used
1.3.6.1.4.1.4756.20.240.20.1.58ColumnfTECE1Timeslot22read-writecurrentFRM220-FTEC E1 timeslot 22: 0:No use 1:used
1.3.6.1.4.1.4756.20.240.20.1.59ColumnfTECE1Timeslot23read-writecurrentFRM220-FTEC E1 timeslot 23: 0:No use 1:used
1.3.6.1.4.1.4756.20.240.20.1.60ColumnfTECE1Timeslot24read-writecurrentFRM220-FTEC E1 timeslot 24: 0:No use 1:used
1.3.6.1.4.1.4756.20.240.20.1.61ColumnfTECE1Timeslot25read-writecurrentFRM220-FTEC E1 timeslot 25: 0:No use 1:used
1.3.6.1.4.1.4756.20.240.20.1.62ColumnfTECE1Timeslot26read-writecurrentFRM220-FTEC E1 timeslot 26: 0:No use 1:used
1.3.6.1.4.1.4756.20.240.20.1.63ColumnfTECE1Timeslot27read-writecurrentFRM220-FTEC E1 timeslot 27: 0:No use 1:used
1.3.6.1.4.1.4756.20.240.20.1.64ColumnfTECE1Timeslot28read-writecurrentFRM220-FTEC E1 timeslot 28: 0:No use 1:used
1.3.6.1.4.1.4756.20.240.20.1.65ColumnfTECE1Timeslot29read-writecurrentFRM220-FTEC E1 timeslot 29: 0:No use 1:used
1.3.6.1.4.1.4756.20.240.20.1.66ColumnfTECE1Timeslot30read-writecurrentFRM220-FTEC E1 timeslot 30: 0:No use 1:used
1.3.6.1.4.1.4756.20.240.20.1.67ColumnfTECE1Timeslot31read-writecurrentFRM220-FTEC E1 timeslot 31: 0:No use 1:used
1.3.6.1.4.1.4756.20.240.20.1.68ColumnfTECDataVoice1read-writecurrentFRM220-FTEC Data/Voice 1: 0:Data 1:Voice
1.3.6.1.4.1.4756.20.240.20.1.69ColumnfTECDataVoice2read-writecurrentFRM220-FTEC Data/Voice 2: 0:Data 1:Voice
1.3.6.1.4.1.4756.20.240.20.1.70ColumnfTECDataVoice3read-writecurrentFRM220-FTEC Data/Voice 3: 0:Data 1:Voice
1.3.6.1.4.1.4756.20.240.20.1.71ColumnfTECDataVoice4read-writecurrentFRM220-FTEC Data/Voice 4: 0:Data 1:Voice
1.3.6.1.4.1.4756.20.240.20.1.72ColumnfTECDataVoice5read-writecurrentFRM220-FTEC Data/Voice 5: 0:Data 1:Voice
1.3.6.1.4.1.4756.20.240.20.1.73ColumnfTECDataVoice6read-writecurrentFRM220-FTEC Data/Voice 6: 0:Data 1:Voice
1.3.6.1.4.1.4756.20.240.20.1.74ColumnfTECDataVoice7read-writecurrentFRM220-FTEC Data/Voice 7: 0:Data 1:Voice
1.3.6.1.4.1.4756.20.240.20.1.75ColumnfTECDataVoice8read-writecurrentFRM220-FTEC Data/Voice 8: 0:Data 1:Voice
1.3.6.1.4.1.4756.20.240.20.1.76ColumnfTECDataVoice9read-writecurrentFRM220-FTEC Data/Voice 9: 0:Data 1:Voice
1.3.6.1.4.1.4756.20.240.20.1.77ColumnfTECDataVoice10read-writecurrentFRM220-FTEC Data/Voice 10: 0:Data 1:Voice
1.3.6.1.4.1.4756.20.240.20.1.78ColumnfTECDataVoice11read-writecurrentFRM220-FTEC Data/Voice 11: 0:Data 1:Voice
1.3.6.1.4.1.4756.20.240.20.1.79ColumnfTECDataVoice12read-writecurrentFRM220-FTEC Data/Voice 12: 0:Data 1:Voice
1.3.6.1.4.1.4756.20.240.20.1.80ColumnfTECDataVoice13read-writecurrentFRM220-FTEC Data/Voice 13: 0:Data 1:Voice
1.3.6.1.4.1.4756.20.240.20.1.81ColumnfTECDataVoice14read-writecurrentFRM220-FTEC Data/Voice 14: 0:Data 1:Voice
1.3.6.1.4.1.4756.20.240.20.1.82ColumnfTECDataVoice15read-writecurrentFRM220-FTEC Data/Voice 15: 0:Data 1:Voice
1.3.6.1.4.1.4756.20.240.20.1.83ColumnfTECDataVoice16read-writecurrentFRM220-FTEC Data/Voice 16: 0:Data 1:Voice
1.3.6.1.4.1.4756.20.240.20.1.84ColumnfTECDataVoice17read-writecurrentFRM220-FTEC Data/Voice 17: 0:Data 1:Voice
1.3.6.1.4.1.4756.20.240.20.1.85ColumnfTECDataVoice18read-writecurrentFRM220-FTEC Data/Voice 18: 0:Data 1:Voice
1.3.6.1.4.1.4756.20.240.20.1.86ColumnfTECDataVoice19read-writecurrentFRM220-FTEC Data/Voice 19: 0:Data 1:Voice
1.3.6.1.4.1.4756.20.240.20.1.87ColumnfTECDataVoice20read-writecurrentFRM220-FTEC Data/Voice 20: 0:Data 1:Voice
1.3.6.1.4.1.4756.20.240.20.1.88ColumnfTECDataVoice21read-writecurrentFRM220-FTEC Data/Voice 21: 0:Data 1:Voice
1.3.6.1.4.1.4756.20.240.20.1.89ColumnfTECDataVoice22read-writecurrentFRM220-FTEC Data/Voice 22: 0:Data 1:Voice
1.3.6.1.4.1.4756.20.240.20.1.90ColumnfTECDataVoice23read-writecurrentFRM220-FTEC Data/Voice 23: 0:Data 1:Voice
1.3.6.1.4.1.4756.20.240.20.1.91ColumnfTECDataVoice24read-writecurrentFRM220-FTEC Data/Voice 24: 0:Data 1:Voice
1.3.6.1.4.1.4756.20.250Nodefom04LocalCards
1.3.6.1.4.1.4756.20.250.20Tablefom04LocalTablenot-accessiblecurrentA list of local FRM220-FOM04 series card entries. The number of entries is fom04-No-L.
1.3.6.1.4.1.4756.20.250.20.1Rowfom04LocalEntrynot-accessiblecurrentAn entry containing management information applicable to a particular local FRM220-FOM04 series card.
1.3.6.1.4.1.4756.20.250.20.1.1Columnfom04ChassisIndexLocalread-onlycurrentA unique value for each local card. It is the chassis location number.
1.3.6.1.4.1.4756.20.250.20.1.2Columnfom04SlotIndexLocalread-onlycurrentA unique value for each local card. It is the slot location number.
1.3.6.1.4.1.4756.20.250.20.1.3Columnfom04CardHWVerLocalread-onlycurrentLocal FRM220-FOM04 Series card hardware version x.xxx
1.3.6.1.4.1.4756.20.250.20.1.4Columnfom04CardFWVerLocalread-onlycurrentLocal FRM220-FOM04 Series card firmware version x.xxx
1.3.6.1.4.1.4756.20.250.20.1.5Columnfom04CardCPLDVerLocalread-onlycurrentLocal FRM220-FOM04 Series card CPLD version x.xxx
1.3.6.1.4.1.4756.20.250.20.1.6Columnfom04CardFPGAVerLocalread-onlycurrentLocal FRM220-FOM04 Series card FPGA version x.xxx
1.3.6.1.4.1.4756.20.250.20.1.7Columnfom04PortActiveLocalread-writecurrentLocal FRM220-FOM04 Series card active: 0:Disable 1:Enable
1.3.6.1.4.1.4756.20.250.20.1.8Columnfom04SettoDefaultLocalread-writecurrentLocal FRM220-FOM04 Series card set to default: 0:OFF 1:Action
1.3.6.1.4.1.4756.20.250.20.1.9Columnfom04PortResetLocalread-writecurrentLocal FRM220-FOM04 Series card portreset: 0:OFF 1:Action
1.3.6.1.4.1.4756.20.250.20.1.10Columnfom04FxLinkLocalread-onlycurrentLocal FRM220-FOM04 fiber link status: 0:Down 1:up
1.3.6.1.4.1.4756.20.250.20.1.11Columnfom04FxWorkCHLocalread-writecurrentLocal FRM220-FOM04 fiber work channel: 0:Optical 1 1:Optical 2
1.3.6.1.4.1.4756.20.250.20.1.12Columnfom04Fx1RxLinkLocalread-onlycurrentLocal FRM220-FOM04 fiber 1 rx loss status: 0:Down 1:Up
1.3.6.1.4.1.4756.20.250.20.1.13Columnfom04Fx2RxLinkLocalread-onlycurrentLocal FRM220-FOM04 fiber 1 rx loss status: 0:Down 1:Up
1.3.6.1.4.1.4756.20.250.20.1.14Columnfom04FxLBSettingLocalread-writecurrentLocal FRM220-FOM04 loopback mode: 0:Disable 1:LLB 2:RLB
1.3.6.1.4.1.4756.20.250.20.1.15Columnfom04Utp1LinkLocalread-onlycurrentLocal FRM220-FOM04 UTP 1 link status: 0:Down 1:Up
1.3.6.1.4.1.4756.20.250.20.1.16Columnfom04Utp1NegoSTSLocalread-onlycurrentLocal FRM220-FOM04 UTP 1 negotiation status: 0:Manual 1:Auto
1.3.6.1.4.1.4756.20.250.20.1.17Columnfom04Utp1SpeedSTSLocalread-onlycurrentLocal FRM220-FOM04 UTP 1 speed status: 0:10M 1:100M
1.3.6.1.4.1.4756.20.250.20.1.18Columnfom04Utp1DuplexSTSLocalread-onlycurrentLocal FRM220-FOM04 UTP 1 duplex status: 0:Half 1:Full
1.3.6.1.4.1.4756.20.250.20.1.19Columnfom04Utp1ActiveLocalread-writecurrentLocal FRM220-FOM04 UTP 1 port active: 0:Disable 1:Enable
1.3.6.1.4.1.4756.20.250.20.1.20Columnfom04Utp1NegoLocalread-writecurrentLocal FRM220-FOM04 UTP 1 negoiation: 0:Manual 1:Auto
1.3.6.1.4.1.4756.20.250.20.1.21Columnfom04Utp1SpeedLocalread-writecurrentLocal FRM220-FOM04 UTP 1 speed: 0:On 1:Off
1.3.6.1.4.1.4756.20.250.20.1.22Columnfom04Utp1DuplexLocalread-writecurrentLocal FRM220-FOM04 UTP 1 duplex: 0:Half 1:Full
1.3.6.1.4.1.4756.20.250.20.1.23Columnfom04Utp2LinkLocalread-onlycurrentLocal FRM220-FOM04 UTP 2 link status: 0:Down 1:Up
1.3.6.1.4.1.4756.20.250.20.1.24Columnfom04Utp2NegoSTSLocalread-onlycurrentLocal FRM220-FOM04 UTP 2 negotiation status: 0:Manual 1:Auto
1.3.6.1.4.1.4756.20.250.20.1.25Columnfom04Utp2SpeedSTSLocalread-onlycurrentLocal FRM220-FOM04 UTP 2 speed status: 0:10M 1:100M
1.3.6.1.4.1.4756.20.250.20.1.26Columnfom04Utp2DuplexSTSLocalread-onlycurrentLocal FRM220-FOM04 UTP 2 duplex status: 0:Half 1:Full
1.3.6.1.4.1.4756.20.250.20.1.27Columnfom04Utp2ActiveLocalread-writecurrentLocal FRM220-FOM04 UTP 2 port active: 0:Disable 1:Enable
1.3.6.1.4.1.4756.20.250.20.1.28Columnfom04Utp2NegoLocalread-writecurrentLocal FRM220-FOM04 UTP 2 negoiation: 0:Manual 1:Auto
1.3.6.1.4.1.4756.20.250.20.1.29Columnfom04Utp2SpeedLocalread-writecurrentLocal FRM220-FOM04 UTP 2 speed: 0:On 1:Off
1.3.6.1.4.1.4756.20.250.20.1.30Columnfom04Utp2DuplexLocalread-writecurrentLocal FRM220-FOM04 UTP 2 duplex: 0:Half 1:Full
1.3.6.1.4.1.4756.20.250.20.1.31Columnfom04Utp3LinkLocalread-onlycurrentLocal FRM220-FOM04 UTP 3 link status: 0:Down 1:Up
1.3.6.1.4.1.4756.20.250.20.1.32Columnfom04Utp3NegoSTSLocalread-onlycurrentLocal FRM220-FOM04 UTP 3 negotiation status: 0:Manual 1:Auto
1.3.6.1.4.1.4756.20.250.20.1.33Columnfom04Utp3SpeedSTSLocalread-onlycurrentLocal FRM220-FOM04 UTP 3 speed status: 0:10M 1:100M
1.3.6.1.4.1.4756.20.250.20.1.34Columnfom04Utp3DuplexSTSLocalread-onlycurrentLocal FRM220-FOM04 UTP 3 duplex status: 0:Half 1:Full
1.3.6.1.4.1.4756.20.250.20.1.35Columnfom04Utp3ActiveLocalread-writecurrentLocal FRM220-FOM04 UTP 3 port active: 0:Disable 1:Enable
1.3.6.1.4.1.4756.20.250.20.1.36Columnfom04Utp3NegoLocalread-writecurrentLocal FRM220-FOM04 UTP 3 negoiation: 0:Manual 1:Auto
1.3.6.1.4.1.4756.20.250.20.1.37Columnfom04Utp3SpeedLocalread-writecurrentLocal FRM220-FOM04 UTP 3 speed: 0:On 1:Off
1.3.6.1.4.1.4756.20.250.20.1.38Columnfom04Utp3DuplexLocalread-writecurrentLocal FRM220-FOM04 UTP 3 duplex: 0:Half 1:Full
1.3.6.1.4.1.4756.20.250.20.1.39Columnfom04RS232ActiveLocalread-writecurrentLocal FRM220-FOM04 RS232 port active: 0:Disable 1:Enable
1.3.6.1.4.1.4756.20.250.20.1.40Columnfom04RS232DataActiveLocalread-onlycurrentLocal FRM220-FOM04 RS232 Rx active status: 0:OFF 1:ON
1.3.6.1.4.1.4756.20.250.20.1.41Columnfom04RS232LBSettingLocalread-writecurrentLocal FRM220-FOM04 RS232 loopback : 0:Disable 1:LLB 2:RLB
1.3.6.1.4.1.4756.20.250.20.1.42Columnfom04E1T1TermLocalread-writecurrentLocal FRM220-FOM04 E1T1 termination type: 0:E1/75/BNC 1:E1/120/RJ45 2:T1/100/RJ45
1.3.6.1.4.1.4756.20.250.20.1.43Columnfom04E1T1CH1ActiveLocalread-writecurrentLocal FRM220-FOM04 E1T1 channel 1 port active : 0:Disable 1:Enalbe
1.3.6.1.4.1.4756.20.250.20.1.44Columnfom04E1T1CH1LinkLocalread-onlycurrentLocal FRM220-FOM04 E1T1 channel 1 link status: 0:Down 1:Up
1.3.6.1.4.1.4756.20.250.20.1.45Columnfom04E1T1CH1BVPErrorLocalread-onlycurrentLocal FRM220-FOM04 E1T1 channel 1 BVP error status : 0:Normal 1:Error
1.3.6.1.4.1.4756.20.250.20.1.46Columnfom04E1T1CH1LineCodeLocalread-writecurrentLocal FRM220-FOM04 E1T1 channel 1 line code: 0:HDB3/B8ZS 1:AMI
1.3.6.1.4.1.4756.20.250.20.1.47Columnfom04E1T1CH1ELBLocalread-writecurrentLocal FRM220-FOM04 E1T1 channel 1 E1 loopback: 0:Disable 1:LLB 2:RLB
1.3.6.1.4.1.4756.20.250.20.1.48Columnfom04E1T1CH1RcvAISLocalread-onlycurrentLocal FRM220-FOM04 E1T1 channel 1 Rev AIS: 0:OFF 1:ON
1.3.6.1.4.1.4756.20.250.20.1.49Columnfom04E1T1CH2ActiveLocalread-writecurrentLocal FRM220-FOM04 E1T1 channel 2 port active : 0:Disable 1:Enalbe
1.3.6.1.4.1.4756.20.250.20.1.50Columnfom04E1T1CH2LinkLocalread-onlycurrentLocal FRM220-FOM04 E1T1 channel 2 link status: 0:Down 1:Up
1.3.6.1.4.1.4756.20.250.20.1.51Columnfom04E1T1CH2BVPErrorLocalread-onlycurrentLocal FRM220-FOM04 E1T1 channel 2 BVP error status : 0:Normal 1:Error
1.3.6.1.4.1.4756.20.250.20.1.52Columnfom04E1T1CH2LineCodeLocalread-writecurrentLocal FRM220-FOM04 E1T1 channel 2 line code: 0:HDB3/B8ZS 1:AMI
1.3.6.1.4.1.4756.20.250.20.1.53Columnfom04E1T1CH2ELBLocalread-writecurrentLocal FRM220-FOM04 E1T1 channel 2 E1 loopback: 0:Disable 1:LLB 2:RLB
1.3.6.1.4.1.4756.20.250.20.1.54Columnfom04E1T1CH2RcvAISLocalread-onlycurrentLocal FRM220-FOM04 E1T1 channel 2 Rev AIS: 0:OFF 1:ON
1.3.6.1.4.1.4756.20.250.20.1.55Columnfom04E1T1CH3ActiveLocalread-writecurrentLocal FRM220-FOM04 E1T1 channel 3 port active : 0:Disable 1:Enalbe
1.3.6.1.4.1.4756.20.250.20.1.56Columnfom04E1T1CH3LinkLocalread-onlycurrentLocal FRM220-FOM04 E1T1 channel 3 link status: 0:Down 1:Up
1.3.6.1.4.1.4756.20.250.20.1.57Columnfom04E1T1CH3BVPErrorLocalread-onlycurrentLocal FRM220-FOM04 E1T1 channel 3 BVP error status : 0:Normal 1:Error
1.3.6.1.4.1.4756.20.250.20.1.58Columnfom04E1T1CH3LineCodeLocalread-writecurrentLocal FRM220-FOM04 E1T1 channel 3 line code: 0:HDB3/B8ZS 1:AMI
1.3.6.1.4.1.4756.20.250.20.1.59Columnfom04E1T1CH3ELBLocalread-writecurrentLocal FRM220-FOM04 E1T1 channel 3 E1 loopback: 0:Disable 1:LLB 2:RLB
1.3.6.1.4.1.4756.20.250.20.1.60Columnfom04E1T1CH3RcvAISLocalread-onlycurrentLocal FRM220-FOM04 E1T1 channel 3 Rev AIS: 0:OFF 1:ON
1.3.6.1.4.1.4756.20.250.20.1.61Columnfom04E1T1CH4ActiveLocalread-writecurrentLocal FRM220-FOM04 E1T1 channel 4 port active : 0:Disable 1:Enalbe
1.3.6.1.4.1.4756.20.250.20.1.62Columnfom04E1T1CH4LinkLocalread-onlycurrentLocal FRM220-FOM04 E1T1 channel 4 link status: 0:Down 1:Up
1.3.6.1.4.1.4756.20.250.20.1.63Columnfom04E1T1CH4BVPErrorLocalread-onlycurrentLocal FRM220-FOM04 E1T1 channel 4 BVP error status : 0:Normal 1:Error
1.3.6.1.4.1.4756.20.250.20.1.64Columnfom04E1T1CH4LineCodeLocalread-writecurrentLocal FRM220-FOM04 E1T1 channel 4 line code: 0:HDB3/B8ZS 1:AMI
1.3.6.1.4.1.4756.20.250.20.1.65Columnfom04E1T1CH4ELBLocalread-writecurrentLocal FRM220-FOM04 E1T1 channel 4 E1 loopback: 0:Disable 1:LLB 2:RLB
1.3.6.1.4.1.4756.20.250.20.1.66Columnfom04E1T1CH4RcvAISLocalread-onlycurrentLocal FRM220-FOM04 E1T1 channel 4 Rev AIS: 0:OFF 1:ON
1.3.6.1.4.1.4756.20.250.20.1.67Columnfom04PhoneActiveLocalread-writecurrentLocal FRM220-FOM04 phone port active : 0:Disable 1:Enable
1.3.6.1.4.1.4756.20.250.20.1.68Columnfom04CallOutLocalread-writecurrentLocal FRM220-FOM04 call out : 0:OFF 1:ON
1.3.6.1.4.1.4756.20.250.20.1.69Columnfom04RemotePWRLocalread-onlycurrentLocal FRM220-FOM04 Remote power fail: 0:Ok 1:Abnormal
1.3.6.1.4.1.4756.20.250.20.1.70Columnfom04LfpModeLocalread-writecurrentLocal FRM220-FOM04 LFP mode: 0:Disable 1:Enable
1.3.6.1.4.1.4756.20.250.20.1.71Columnfom04AlsModeLocalread-writecurrentLocal FRM220-FOM04 ALS mode: 0:Disable 1:Enable
1.3.6.1.4.1.4756.20.250.20.1.72Columnfom04SnmpPortLocalread-writecurrentLocal FRM220-FOM04 SNMP VLAN : 0:No VLAN 1:Port 1 VLAN
1.3.6.1.4.1.4756.20.250.20.1.73Columnfom04PWR1Localread-onlycurrentLocal FRM220-FOM04 PWR 1 (AC): 0:Fail 1:Ok 2:None
1.3.6.1.4.1.4756.20.250.20.1.74Columnfom04PWR2Localread-onlycurrentLocal FRM220-FOM04 PWR 2 (DC): 0:Fail 1:Ok 2:None
1.3.6.1.4.1.4756.20.250.20.1.75Columnfom04Fx1DDLocalread-onlycurrentLocal device card fiber port 1 Digital Diagnostic function: 0:No 1:Yes
1.3.6.1.4.1.4756.20.250.20.1.76Columnfom04Fx1DDVendorLocalread-onlycurrentLocal device card fiber port 1 D/D information: Vendor name
1.3.6.1.4.1.4756.20.250.20.1.77Columnfom04Fx1DDPartNoLocalread-onlycurrentLocal device card fiber port 1 D/D information: Vendor part number
1.3.6.1.4.1.4756.20.250.20.1.78Columnfom04Fx1DDFiberTypeLocalread-onlycurrentLocal device card fiber port 1 D/D information: Fiber Type
1.3.6.1.4.1.4756.20.250.20.1.79Columnfom04Fx1DDWaveLenLocalread-onlycurrentLocal device card fiber port 1 D/D information: Wave length
1.3.6.1.4.1.4756.20.250.20.1.80Columnfom04Fx1DDWaveLen2Localread-onlycurrentLocal device card fiber port 1 D/D information: Wave length 2
1.3.6.1.4.1.4756.20.250.20.1.81Columnfom04Fx1DDLinkLenLocalread-onlycurrentLocal device card fiber port 1 D/D information: Link length
1.3.6.1.4.1.4756.20.250.20.1.82Columnfom04Fx1DDLenUnitLocalread-onlycurrentLocal device card fiber port 1 D/D information: Length Unit
1.3.6.1.4.1.4756.20.250.20.1.83Columnfom04Fx1DDStatusLocalread-onlycurrentLocal device card fiber port 1 D/D information: Status Support
1.3.6.1.4.1.4756.20.250.20.1.84Columnfom04Fx1DDRxSensLocalread-onlycurrentLocal device card fiber port 1 D/D information: Rx Sensitivity
1.3.6.1.4.1.4756.20.250.20.1.85Columnfom04Fx1DDTxPWRLocalread-onlycurrentLocal device card fiber port 1 D/D information: Tx power
1.3.6.1.4.1.4756.20.250.20.1.86Columnfom04Fx1DDRxPWRLocalread-onlycurrentLocal device card fiber port 1 D/D information: Rx power
1.3.6.1.4.1.4756.20.250.20.1.87Columnfom04Fx1DDTempLocalread-onlycurrentLocal device card fiber port 1 D/D information: Temperature in degree C
1.3.6.1.4.1.4756.20.250.20.1.88Columnfom04Fx1DDPWRMarginLocalread-onlycurrentLocal device card fiber port 1 D/D information: Power margin
1.3.6.1.4.1.4756.20.250.20.1.89Columnfom04Fx2DDLocalread-onlycurrentLocal device card fiber port 2 Digital Diagnostic function: 0:No 1:Yes
1.3.6.1.4.1.4756.20.250.20.1.90Columnfom04Fx2DDVendorLocalread-onlycurrentLocal device card fiber port 2 D/D information: Vendor name
1.3.6.1.4.1.4756.20.250.20.1.91Columnfom04Fx2DDPartNoLocalread-onlycurrentLocal device card fiber port 2 D/D information: Vendor part number
1.3.6.1.4.1.4756.20.250.20.1.92Columnfom04Fx2DDFiberTypeLocalread-onlycurrentLocal device card fiber port 2 D/D information: Fiber Type
1.3.6.1.4.1.4756.20.250.20.1.93Columnfom04Fx2DDWaveLenLocalread-onlycurrentLocal device card fiber port 2 D/D information: Wave length
1.3.6.1.4.1.4756.20.250.20.1.94Columnfom04Fx2DDWaveLen2Localread-onlycurrentLocal device card fiber port 2 D/D information: Wave length 2
1.3.6.1.4.1.4756.20.250.20.1.95Columnfom04Fx2DDLinkLenLocalread-onlycurrentLocal device card fiber port 2 D/D information: Link length
1.3.6.1.4.1.4756.20.250.20.1.96Columnfom04Fx2DDLenUnitLocalread-onlycurrentLocal device card fiber port 2 D/D information: Length Unit
1.3.6.1.4.1.4756.20.250.20.1.97Columnfom04Fx2DDStatusLocalread-onlycurrentLocal device card fiber port 2 D/D information: Status Support
1.3.6.1.4.1.4756.20.250.20.1.98Columnfom04Fx2DDRxSensLocalread-onlycurrentLocal device card fiber port 2 D/D information: Rx Sensitivity
1.3.6.1.4.1.4756.20.250.20.1.99Columnfom04Fx2DDTxPWRLocalread-onlycurrentLocal device card fiber port 2 D/D information: Tx power
1.3.6.1.4.1.4756.20.250.20.1.100Columnfom04Fx2DDRxPWRLocalread-onlycurrentLocal device card fiber port 2 D/D information: Rx power
1.3.6.1.4.1.4756.20.250.20.1.101Columnfom04Fx2DDTempLocalread-onlycurrentLocal device card fiber port 2 D/D information: Temperature in degree C
1.3.6.1.4.1.4756.20.250.20.1.102Columnfom04Fx2DDPWRMarginLocalread-onlycurrentLocal device card fiber port 2 D/D information: Power margin
1.3.6.1.4.1.4756.20.250.20.1.103Columnfom04FxFEFLocalread-onlycurrentLocal device card fiber detected Far End Fault: 0:Undetect 1:Detected
1.3.6.1.4.1.4756.20.251Nodefom04RemoteCards
1.3.6.1.4.1.4756.20.251.20Tablefom04RemoteTablenot-accessiblecurrentA list of local FRM220-FOM04 series card entries. The number of entries is fom04-No-R.
1.3.6.1.4.1.4756.20.251.20.1Rowfom04RemoteEntrynot-accessiblecurrentAn entry containing management information applicable to a particular remote FRM220-FOM04 series card.
1.3.6.1.4.1.4756.20.251.20.1.1Columnfom04ChassisIndexRemoteread-onlycurrentA unique value for each remote card. It is the chassis location number.
1.3.6.1.4.1.4756.20.251.20.1.2Columnfom04SlotIndexRemoteread-onlycurrentA unique value for each remote card. It is the slot location number.
1.3.6.1.4.1.4756.20.251.20.1.3Columnfom04CardHWVerRemoteread-onlycurrentRemote FRM220-FOM04 Series card hardware version x.xxx
1.3.6.1.4.1.4756.20.251.20.1.4Columnfom04CardFWVerRemoteread-onlycurrentRemote FRM220-FOM04 Series card firmware version x.xxx
1.3.6.1.4.1.4756.20.251.20.1.5Columnfom04CardCPLDVerRemoteread-onlycurrentRemote FRM220-FOM04 Series card CPLD version x.xxx
1.3.6.1.4.1.4756.20.251.20.1.6Columnfom04CardFPGAVerRemoteread-onlycurrentRemote FRM220-FOM04 Series card FPGA version x.xxx
1.3.6.1.4.1.4756.20.251.20.1.7Columnfom04PortActiveRemoteread-onlycurrentRemote FRM220-FOM04 Series card active: 0:Disable 1:Enable
1.3.6.1.4.1.4756.20.251.20.1.8Columnfom04SettoDefaultRemoteread-writecurrentRemote FRM220-FOM04 Series card set to default: 0:OFF 1:Action
1.3.6.1.4.1.4756.20.251.20.1.9Columnfom04PortResetRemoteread-writecurrentRemote FRM220-FOM04 Series card portreset: 0:OFF 1:Action
1.3.6.1.4.1.4756.20.251.20.1.10Columnfom04FxLinkRemoteread-onlycurrentRemote FRM220-FOM04 fiber link status: 0:Down 1:up
1.3.6.1.4.1.4756.20.251.20.1.11Columnfom04FxWorkCHRemoteread-writecurrentRemote FRM220-FOM04 fiber work channel: 0:Optical 1 1:Optical 2
1.3.6.1.4.1.4756.20.251.20.1.12Columnfom04Fx1RxLinkRemoteread-onlycurrentRemote FRM220-FOM04 fiber 1 rx loss status: 0:Down 1:Up
1.3.6.1.4.1.4756.20.251.20.1.13Columnfom04Fx2RxLinkRemoteread-onlycurrentRemote FRM220-FOM04 fiber 1 rx loss status: 0:Down 1:Up
1.3.6.1.4.1.4756.20.251.20.1.14Columnfom04FxLBSettingRemoteread-writecurrentRemote FRM220-FOM04 loopback mode: 0:Disable 1:LLB 2:RLB
1.3.6.1.4.1.4756.20.251.20.1.15Columnfom04Utp1LinkRemoteread-onlycurrentRemote FRM220-FOM04 UTP 1 link status: 0:Down 1:Up
1.3.6.1.4.1.4756.20.251.20.1.16Columnfom04Utp1NegoSTSRemoteread-onlycurrentRemote FRM220-FOM04 UTP 1 negotiation status: 0:Manual 1:Auto
1.3.6.1.4.1.4756.20.251.20.1.17Columnfom04Utp1SpeedSTSRemoteread-onlycurrentRemote FRM220-FOM04 UTP 1 speed status: 0:10M 1:100M
1.3.6.1.4.1.4756.20.251.20.1.18Columnfom04Utp1DuplexSTSRemoteread-onlycurrentRemote FRM220-FOM04 UTP 1 duplex status: 0:Half 1:Full
1.3.6.1.4.1.4756.20.251.20.1.19Columnfom04Utp1ActiveRemoteread-writecurrentRemote FRM220-FOM04 UTP 1 port active: 0:Disable 1:Enable
1.3.6.1.4.1.4756.20.251.20.1.20Columnfom04Utp1NegoRemoteread-writecurrentRemote FRM220-FOM04 UTP 1 negoiation: 0:Manual 1:Auto
1.3.6.1.4.1.4756.20.251.20.1.21Columnfom04Utp1SpeedRemoteread-writecurrentRemote FRM220-FOM04 UTP 1 speed: 0:On 1:Off
1.3.6.1.4.1.4756.20.251.20.1.22Columnfom04Utp1DuplexRemoteread-writecurrentRemote FRM220-FOM04 UTP 1 duplex: 0:Half 1:Full
1.3.6.1.4.1.4756.20.251.20.1.23Columnfom04Utp2LinkRemoteread-onlycurrentRemote FRM220-FOM04 UTP 2 link status: 0:Down 1:Up
1.3.6.1.4.1.4756.20.251.20.1.24Columnfom04Utp2NegoSTSRemoteread-onlycurrentRemote FRM220-FOM04 UTP 2 negotiation status: 0:Manual 1:Auto
1.3.6.1.4.1.4756.20.251.20.1.25Columnfom04Utp2SpeedSTSRemoteread-onlycurrentRemote FRM220-FOM04 UTP 2 speed status: 0:10M 1:100M
1.3.6.1.4.1.4756.20.251.20.1.26Columnfom04Utp2DuplexSTSRemoteread-onlycurrentRemote FRM220-FOM04 UTP 2 duplex status: 0:Half 1:Full
1.3.6.1.4.1.4756.20.251.20.1.27Columnfom04Utp2ActiveRemoteread-writecurrentRemote FRM220-FOM04 UTP 2 port active: 0:Disable 1:Enable
1.3.6.1.4.1.4756.20.251.20.1.28Columnfom04Utp2NegoRemoteread-writecurrentRemote FRM220-FOM04 UTP 2 negoiation: 0:Manual 1:Auto
1.3.6.1.4.1.4756.20.251.20.1.29Columnfom04Utp2SpeedRemoteread-writecurrentRemote FRM220-FOM04 UTP 2 speed: 0:On 1:Off
1.3.6.1.4.1.4756.20.251.20.1.30Columnfom04Utp2DuplexRemoteread-writecurrentRemote FRM220-FOM04 UTP 2 duplex: 0:Half 1:Full
1.3.6.1.4.1.4756.20.251.20.1.31Columnfom04Utp3LinkRemoteread-onlycurrentRemote FRM220-FOM04 UTP 3 link status: 0:Down 1:Up
1.3.6.1.4.1.4756.20.251.20.1.32Columnfom04Utp3NegoSTSRemoteread-onlycurrentRemote FRM220-FOM04 UTP 3 negotiation status: 0:Manual 1:Auto
1.3.6.1.4.1.4756.20.251.20.1.33Columnfom04Utp3SpeedSTSRemoteread-onlycurrentRemote FRM220-FOM04 UTP 3 speed status: 0:10M 1:100M
1.3.6.1.4.1.4756.20.251.20.1.34Columnfom04Utp3DuplexSTSRemoteread-onlycurrentRemote FRM220-FOM04 UTP 3 duplex status: 0:Half 1:Full
1.3.6.1.4.1.4756.20.251.20.1.35Columnfom04Utp3ActiveRemoteread-writecurrentRemote FRM220-FOM04 UTP 3 port active: 0:Disable 1:Enable
1.3.6.1.4.1.4756.20.251.20.1.36Columnfom04Utp3NegoRemoteread-writecurrentRemote FRM220-FOM04 UTP 3 negoiation: 0:Manual 1:Auto
1.3.6.1.4.1.4756.20.251.20.1.37Columnfom04Utp3SpeedRemoteread-writecurrentRemote FRM220-FOM04 UTP 3 speed: 0:On 1:Off
1.3.6.1.4.1.4756.20.251.20.1.38Columnfom04Utp3DuplexRemoteread-writecurrentRemote FRM220-FOM04 UTP 3 duplex: 0:Half 1:Full
1.3.6.1.4.1.4756.20.251.20.1.39Columnfom04RS232ActiveRemoteread-writecurrentRemote FRM220-FOM04 RS232 port active: 0:Disable 1:Enable
1.3.6.1.4.1.4756.20.251.20.1.40Columnfom04RS232DataActiveRemoteread-onlycurrentRemote FRM220-FOM04 RS232 Rx active status: 0:OFF 1:ON
1.3.6.1.4.1.4756.20.251.20.1.41Columnfom04RS232LBSettingRemoteread-writecurrentRemote FRM220-FOM04 RS232 loopback : 0:Disable 1:LLB 2:RLB
1.3.6.1.4.1.4756.20.251.20.1.42Columnfom04E1T1TermRemoteread-writecurrentRemote FRM220-FOM04 E1T1 termination type: 0:E1/75/BNC 1:E1/120/RJ45 2:T1/100/RJ45
1.3.6.1.4.1.4756.20.251.20.1.43Columnfom04E1T1CH1ActiveRemoteread-writecurrentRemote FRM220-FOM04 E1T1 channel 1 port active : 0:Disable 1:Enalbe
1.3.6.1.4.1.4756.20.251.20.1.44Columnfom04E1T1CH1LinkRemoteread-onlycurrentRemote FRM220-FOM04 E1T1 channel 1 link status: 0:Down 1:Up
1.3.6.1.4.1.4756.20.251.20.1.45Columnfom04E1T1CH1BVPErrorRemoteread-onlycurrentRemote FRM220-FOM04 E1T1 channel 1 BVP error status : 0:Normal 1:Error
1.3.6.1.4.1.4756.20.251.20.1.46Columnfom04E1T1CH1LineCodeRemoteread-writecurrentRemote FRM220-FOM04 E1T1 channel 1 line code: 0:HDB3/B8ZS 1:AMI
1.3.6.1.4.1.4756.20.251.20.1.47Columnfom04E1T1CH1ELBRemoteread-writecurrentRemote FRM220-FOM04 E1T1 channel 1 E1 loopback: 0:Disable 1:LLB 2:RLB
1.3.6.1.4.1.4756.20.251.20.1.48Columnfom04E1T1CH1RcvAISRemoteread-onlycurrentRemote FRM220-FOM04 E1T1 channel 1 Rev AIS: 0:OFF 1:ON
1.3.6.1.4.1.4756.20.251.20.1.49Columnfom04E1T1CH2ActiveRemoteread-writecurrentRemote FRM220-FOM04 E1T1 channel 2 port active : 0:Disable 1:Enalbe
1.3.6.1.4.1.4756.20.251.20.1.50Columnfom04E1T1CH2LinkRemoteread-onlycurrentRemote FRM220-FOM04 E1T1 channel 2 link status: 0:Down 1:Up
1.3.6.1.4.1.4756.20.251.20.1.51Columnfom04E1T1CH2BVPErrorRemoteread-onlycurrentRemote FRM220-FOM04 E1T1 channel 2 BVP error status : 0:Normal 1:Error
1.3.6.1.4.1.4756.20.251.20.1.52Columnfom04E1T1CH2LineCodeRemoteread-writecurrentRemote FRM220-FOM04 E1T1 channel 2 line code: 0:HDB3/B8ZS 1:AMI
1.3.6.1.4.1.4756.20.251.20.1.53Columnfom04E1T1CH2ELBRemoteread-writecurrentRemote FRM220-FOM04 E1T1 channel 2 E1 loopback: 0:Disable 1:LLB 2:RLB
1.3.6.1.4.1.4756.20.251.20.1.54Columnfom04E1T1CH2RcvAISRemoteread-onlycurrentRemote FRM220-FOM04 E1T1 channel 2 Rev AIS: 0:OFF 1:ON
1.3.6.1.4.1.4756.20.251.20.1.55Columnfom04E1T1CH3ActiveRemoteread-writecurrentRemote FRM220-FOM04 E1T1 channel 3 port active : 0:Disable 1:Enalbe
1.3.6.1.4.1.4756.20.251.20.1.56Columnfom04E1T1CH3LinkRemoteread-onlycurrentRemote FRM220-FOM04 E1T1 channel 3 link status: 0:Down 1:Up
1.3.6.1.4.1.4756.20.251.20.1.57Columnfom04E1T1CH3BVPErrorRemoteread-onlycurrentRemote FRM220-FOM04 E1T1 channel 3 BVP error status : 0:Normal 1:Error
1.3.6.1.4.1.4756.20.251.20.1.58Columnfom04E1T1CH3LineCodeRemoteread-writecurrentRemote FRM220-FOM04 E1T1 channel 3 line code: 0:HDB3/B8ZS 1:AMI
1.3.6.1.4.1.4756.20.251.20.1.59Columnfom04E1T1CH3ELBRemoteread-writecurrentRemote FRM220-FOM04 E1T1 channel 3 E1 loopback: 0:Disable 1:LLB 2:RLB
1.3.6.1.4.1.4756.20.251.20.1.60Columnfom04E1T1CH3RcvAISRemoteread-onlycurrentRemote FRM220-FOM04 E1T1 channel 3 Rev AIS: 0:OFF 1:ON
1.3.6.1.4.1.4756.20.251.20.1.61Columnfom04E1T1CH4ActiveRemoteread-writecurrentRemote FRM220-FOM04 E1T1 channel 4 port active : 0:Disable 1:Enalbe
1.3.6.1.4.1.4756.20.251.20.1.62Columnfom04E1T1CH4LinkRemoteread-onlycurrentRemote FRM220-FOM04 E1T1 channel 4 link status: 0:Down 1:Up
1.3.6.1.4.1.4756.20.251.20.1.63Columnfom04E1T1CH4BVPErrorRemoteread-onlycurrentRemote FRM220-FOM04 E1T1 channel 4 BVP error status : 0:Normal 1:Error
1.3.6.1.4.1.4756.20.251.20.1.64Columnfom04E1T1CH4LineCodeRemoteread-writecurrentRemote FRM220-FOM04 E1T1 channel 4 line code: 0:HDB3/B8ZS 1:AMI
1.3.6.1.4.1.4756.20.251.20.1.65Columnfom04E1T1CH4ELBRemoteread-writecurrentRemote FRM220-FOM04 E1T1 channel 4 E1 loopback: 0:Disable 1:LLB 2:RLB
1.3.6.1.4.1.4756.20.251.20.1.66Columnfom04E1T1CH4RcvAISRemoteread-onlycurrentRemote FRM220-FOM04 E1T1 channel 4 Rev AIS: 0:OFF 1:ON
1.3.6.1.4.1.4756.20.251.20.1.67Columnfom04PhoneActiveRemoteread-writecurrentRemote FRM220-FOM04 phone port active : 0:Disable 1:Enable
1.3.6.1.4.1.4756.20.251.20.1.68Columnfom04CallOutRemoteread-writecurrentRemote FRM220-FOM04 call out : 0:OFF 1:ON
1.3.6.1.4.1.4756.20.251.20.1.69Columnfom04RemotePWRRemoteread-onlycurrentRemote FRM220-FOM04 Remote power fail: 0:Ok 1:Abnormal
1.3.6.1.4.1.4756.20.251.20.1.70Columnfom04LfpModeRemoteread-writecurrentRemote FRM220-FOM04 LFP mode: 0:Disable 1:Enable
1.3.6.1.4.1.4756.20.251.20.1.71Columnfom04AlsModeRemoteread-writecurrentRemote FRM220-FOM04 ALS mode: 0:Disable 1:Enable
1.3.6.1.4.1.4756.20.251.20.1.72Columnfom04SnmpPortRemoteread-writecurrentRemote FRM220-FOM04 SNMP VLAN : 0:No VLAN 1:Port 1 VLAN
1.3.6.1.4.1.4756.20.251.20.1.73Columnfom04PWR1Remoteread-onlycurrentRemote FRM220-FOM04 PWR 1 (AC): 0:Fail 1:Ok 2:None
1.3.6.1.4.1.4756.20.251.20.1.74Columnfom04PWR2Remoteread-onlycurrentRemote FRM220-FOM04 PWR 2 (DC): 0:Fail 1:Ok 2:None
1.3.6.1.4.1.4756.20.251.20.1.75Columnfom04Fx1DDRemoteread-onlycurrentRemote device card fiber port 1 Digital Diagnostic function: 0:No 1:Yes
1.3.6.1.4.1.4756.20.251.20.1.76Columnfom04Fx1DDVendorRemoteread-onlycurrentRemote device card fiber port 1 D/D information: Vendor name
1.3.6.1.4.1.4756.20.251.20.1.77Columnfom04Fx1DDPartNoRemoteread-onlycurrentRemote device card fiber port 1 D/D information: Vendor part number
1.3.6.1.4.1.4756.20.251.20.1.78Columnfom04Fx1DDFiberTypeRemoteread-onlycurrentRemote device card fiber port 1 D/D information: Fiber Type
1.3.6.1.4.1.4756.20.251.20.1.79Columnfom04Fx1DDWaveLenRemoteread-onlycurrentRemote device card fiber port 1 D/D information: Wave length
1.3.6.1.4.1.4756.20.251.20.1.80Columnfom04Fx1DDWaveLen2Remoteread-onlycurrentRemote device card fiber port 1 D/D information: Wave length 2
1.3.6.1.4.1.4756.20.251.20.1.81Columnfom04Fx1DDLinkLenRemoteread-onlycurrentRemote device card fiber port 1 D/D information: Link length
1.3.6.1.4.1.4756.20.251.20.1.82Columnfom04Fx1DDLenUnitRemoteread-onlycurrentRemote device card fiber port 1 D/D information: Length Unit
1.3.6.1.4.1.4756.20.251.20.1.83Columnfom04Fx1DDStatusRemoteread-onlycurrentRemote device card fiber port 1 D/D information: Status Support
1.3.6.1.4.1.4756.20.251.20.1.84Columnfom04Fx1DDRxSensRemoteread-onlycurrentRemote device card fiber port 1 D/D information: Rx Sensitivity
1.3.6.1.4.1.4756.20.251.20.1.85Columnfom04Fx1DDTxPWRRemoteread-onlycurrentRemote device card fiber port 1 D/D information: Tx power
1.3.6.1.4.1.4756.20.251.20.1.86Columnfom04Fx1DDRxPWRRemoteread-onlycurrentRemote device card fiber port 1 D/D information: Rx power
1.3.6.1.4.1.4756.20.251.20.1.87Columnfom04Fx1DDTempRemoteread-onlycurrentRemote device card fiber port 1 D/D information: Temperature in degree C
1.3.6.1.4.1.4756.20.251.20.1.88Columnfom04Fx1DDPWRMarginRemoteread-onlycurrentRemote device card fiber port 1 D/D information: Power margin
1.3.6.1.4.1.4756.20.251.20.1.89Columnfom04Fx2DDRemoteread-onlycurrentRemote device card fiber port 2 Digital Diagnostic function: 0:No 1:Yes
1.3.6.1.4.1.4756.20.251.20.1.90Columnfom04Fx2DDVendorRemoteread-onlycurrentRemote device card fiber port 2 D/D information: Vendor name
1.3.6.1.4.1.4756.20.251.20.1.91Columnfom04Fx2DDPartNoRemoteread-onlycurrentRemote device card fiber port 2 D/D information: Vendor part number
1.3.6.1.4.1.4756.20.251.20.1.92Columnfom04Fx2DDFiberTypeRemoteread-onlycurrentRemote device card fiber port 2 D/D information: Fiber Type
1.3.6.1.4.1.4756.20.251.20.1.93Columnfom04Fx2DDWaveLenRemoteread-onlycurrentRemote device card fiber port 2 D/D information: Wave length
1.3.6.1.4.1.4756.20.251.20.1.94Columnfom04Fx2DDWaveLen2Remoteread-onlycurrentRemote device card fiber port 2 D/D information: Wave length 2
1.3.6.1.4.1.4756.20.251.20.1.95Columnfom04Fx2DDLinkLenRemoteread-onlycurrentRemote device card fiber port 2 D/D information: Link length
1.3.6.1.4.1.4756.20.251.20.1.96Columnfom04Fx2DDLenUnitRemoteread-onlycurrentRemote device card fiber port 2 D/D information: Length Unit
1.3.6.1.4.1.4756.20.251.20.1.97Columnfom04Fx2DDStatusRemoteread-onlycurrentRemote device card fiber port 2 D/D information: Status Support
1.3.6.1.4.1.4756.20.251.20.1.98Columnfom04Fx2DDRxSensRemoteread-onlycurrentRemote device card fiber port 2 D/D information: Rx Sensitivity
1.3.6.1.4.1.4756.20.251.20.1.99Columnfom04Fx2DDTxPWRRemoteread-onlycurrentRemote device card fiber port 2 D/D information: Tx power
1.3.6.1.4.1.4756.20.251.20.1.100Columnfom04Fx2DDRxPWRRemoteread-onlycurrentRemote device card fiber port 2 D/D information: Rx power
1.3.6.1.4.1.4756.20.251.20.1.101Columnfom04Fx2DDTempRemoteread-onlycurrentRemote device card fiber port 2 D/D information: Temperature in degree C
1.3.6.1.4.1.4756.20.251.20.1.102Columnfom04Fx2DDPWRMarginRemoteread-onlycurrentRemote device card fiber port 2 D/D information: Power margin
1.3.6.1.4.1.4756.20.251.20.1.103Columnfom04FxFEFRemoteread-onlycurrentRemote device card fiber detected Far End Fault: 0:Undetect 1:Detected
1.3.6.1.4.1.4756.20.260Nodef2R4GCards
1.3.6.1.4.1.4756.20.260.20Tablef2R4GTablenot-accessiblecurrentA list of local FRM220-2R4G card entries. The number of entries is f2R4G-No-L.
1.3.6.1.4.1.4756.20.260.20.1Rowf2R4GEntrynot-accessiblecurrentAn entry containing management information applicable to a particular local FRM220-3R27G card.
1.3.6.1.4.1.4756.20.260.20.1.1Columnf2R4GChassisIndexread-onlycurrentA unique value for each local card. It is the chassis location number.
1.3.6.1.4.1.4756.20.260.20.1.2Columnf2R4GSlotIndexread-onlycurrentA unique value for each local card. It is the slot location number.
1.3.6.1.4.1.4756.20.260.20.1.3Columnf2R4GCardHWVerread-onlycurrentLocal FRM220-2R4G card hardware version x.xxx
1.3.6.1.4.1.4756.20.260.20.1.4Columnf2R4GCardFWVerread-onlycurrentLocal FRM220-2R4G card firmware version x.xxx
1.3.6.1.4.1.4756.20.260.20.1.5Columnf2R4GCardCPLDVerread-onlycurrentLocal FRM220-2R4G card CPLD version x.xxx
1.3.6.1.4.1.4756.20.260.20.1.6Columnf2R4GCardFPGAVerread-onlycurrentLocal FRM220-2R4G card FPGA version x.xxx
1.3.6.1.4.1.4756.20.260.20.1.7Columnf2R4GModelread-onlycurrentLocal CardType: 0:FRM220-2R4G/2S 1:FRM220-2R4G/3S
1.3.6.1.4.1.4756.20.260.20.1.8Columnf2R4GDeviceActiveread-writecurrentLocal FRM220-2R4G card active: 0:Inactive 1:Active
1.3.6.1.4.1.4756.20.260.20.1.9Columnf2R4GFx1Linkread-onlycurrentLocal FRM220-2R4G card Fiber1 link status: 0:Down 1:Up
1.3.6.1.4.1.4756.20.260.20.1.10Columnf2R4GFx2Linkread-onlycurrentLocal FRM220-2R4G card Fiber2 link status: 0:Down 1:Up
1.3.6.1.4.1.4756.20.260.20.1.11Columnf2R4GFx3Linkread-onlycurrentLocal FRM220-2R4G card Fiber3 link status: 0:Down 1:Up
1.3.6.1.4.1.4756.20.260.20.1.12Columnf2R4GFx1TxFailread-onlycurrentLocal FRM220-2R4G card Fiber1 Transceiver Tx Detect: 0:Normal 1:Fail
1.3.6.1.4.1.4756.20.260.20.1.13Columnf2R4GFx2TxFailread-onlycurrentLocal FRM220-2R4G card Fiber2 Transceiver Tx Detect: 0:Normal 1:Fail
1.3.6.1.4.1.4756.20.260.20.1.14Columnf2R4GFx3TxFailread-onlycurrentLocal FRM220-2R4G card Fiber3 Transceiver Tx Detect: 0:Normal 1:Fail
1.3.6.1.4.1.4756.20.260.20.1.15Columnf2R4GFx1AlsModeread-writecurrentLocal FRM220-2R4G card Fiber1 Auto Laser Showdown: 0:Disable 1:Enable
1.3.6.1.4.1.4756.20.260.20.1.16Columnf2R4GFx2AlsModeread-writecurrentLocal FRM220-2R4G card Fiber2 Auto Laser Showdown: 0:Disable 1:Enable
1.3.6.1.4.1.4756.20.260.20.1.17Columnf2R4GFx3AlsModeread-writecurrentLocal FRM220-2R4G card Fiber3 Auto Laser Showdown: 0:Disable 1:Enable
1.3.6.1.4.1.4756.20.260.20.1.18Columnf2R4GPortResetread-writecurrentForce local FRM220-2R4G card to reset mode: 0:Off 1:Action
1.3.6.1.4.1.4756.20.260.20.1.19Columnf2R4GActivePathread-writecurrentLocal FRM220-2R4G card Active Protection Path: 0:Primary 1:Secondary
1.3.6.1.4.1.4756.20.260.20.1.20Columnf2R4GOpticFxProread-writecurrentLocal FRM220-2R4G card Optic Fiber Protection: 0:Manual 1:Auto 2:Semi-Auto
1.3.6.1.4.1.4756.20.260.20.1.21Columnf2R4GLbsettingread-writecurrentLocal FRM220-2R4G card Loopback Test: 0:Disable 1:Line side enable 2:Primary and Secondary side enable 3:All enable
1.3.6.1.4.1.4756.20.260.20.1.22Columnf2R4GLossPropagationread-writecurrentLocal FRM220-2R4G card Link Fault Pass-through: 0:Disable 1:Enable
1.3.6.1.4.1.4756.20.260.20.1.23Columnf2R4GSetToDefaultread-writecurrentLocal FRM220-2R4G card set to default: 0:OFF 1:Action
1.3.6.1.4.1.4756.20.260.20.1.24Columnf2R4GFx1DDread-onlycurrentLocal FRM220-2R4G card fiber Digital Diagnostic function: 0:No 1:Yes
1.3.6.1.4.1.4756.20.260.20.1.25Columnf2R4GFx1DDVendorread-onlycurrentLocal FRM220-2R4G card fiber D/D information: Vendor name
1.3.6.1.4.1.4756.20.260.20.1.26Columnf2R4GFx1DDPartNoread-onlycurrentLocal FRM220-2R4G card fiber D/D information: Vendor part number
1.3.6.1.4.1.4756.20.260.20.1.27Columnf2R4GFx1DDVendorSNread-onlycurrentLocal FRM220-2R4G card fiber1 D/D information: Vendor serial number
1.3.6.1.4.1.4756.20.260.20.1.28Columnf2R4GFx1DDFiberTyperead-onlycurrentLocal FRM220-2R4G card fiber D/D information: Fiber Type
1.3.6.1.4.1.4756.20.260.20.1.29Columnf2R4GFx1DDWaveLenread-onlycurrentLocal FRM220-2R4G card fiber D/D information: Wave length
1.3.6.1.4.1.4756.20.260.20.1.30Columnf2R4GFx1DDWaveLen2read-onlycurrentLocal FRM220-2R4G card fiber D/D information: Wave length 2
1.3.6.1.4.1.4756.20.260.20.1.31Columnf2R4GFx1DDLinkLenread-onlycurrentLocal FRM220-2R4G card fiber D/D information: Link length
1.3.6.1.4.1.4756.20.260.20.1.32Columnf2R4GFx1DDLenUnitread-onlycurrentLocal FRM220-2R4G card fiber D/D information: Length Unit
1.3.6.1.4.1.4756.20.260.20.1.33Columnf2R4GFx1DDStatusread-onlycurrentLocal FRM220-2R4G card fiber D/D information: Status Support
1.3.6.1.4.1.4756.20.260.20.1.34Columnf2R4GFx1DDRxSensread-onlycurrentLocal FRM220-2R4G card fiber D/D information: Rx Sensitivity
1.3.6.1.4.1.4756.20.260.20.1.35Columnf2R4GFx1DDTxPWRread-onlycurrentLocal FRM220-2R4G card fiber D/D information: Tx power
1.3.6.1.4.1.4756.20.260.20.1.36Columnf2R4GFx1DDRxPWRread-onlycurrentLocal FRM220-2R4G card fiber D/D information: Rx power
1.3.6.1.4.1.4756.20.260.20.1.37Columnf2R4GFx1DDTempread-onlycurrentLocal FRM220-2R4G card fiber D/D information: Temperature in degree C
1.3.6.1.4.1.4756.20.260.20.1.38Columnf2R4GFx1DDPWRMarginread-onlycurrentLocal FRM220-2R4G card fiber D/D information: Power margin
1.3.6.1.4.1.4756.20.260.20.1.39Columnf2R4GFx2DDread-onlycurrentLocal FRM220-2R4G card fiber2 Digital Diagnostic function: 0:No 1:Yes
1.3.6.1.4.1.4756.20.260.20.1.40Columnf2R4GFx2DDVendorread-onlycurrentLocal FRM220-2R4G card fiber2 D/D information: Vendor name
1.3.6.1.4.1.4756.20.260.20.1.41Columnf2R4GFx2DDPartNoread-onlycurrentLocal FRM220-2R4G card fiber2 D/D information: Vendor part number
1.3.6.1.4.1.4756.20.260.20.1.42Columnf2R4GFx2DDVendorSNread-onlycurrentLocal FRM220-2R4G card fiber2 D/D information: Vendor serial number
1.3.6.1.4.1.4756.20.260.20.1.43Columnf2R4GFx2DDFiberTyperead-onlycurrentLocal FRM220-2R4G card fiber2 D/D information: Fiber Type
1.3.6.1.4.1.4756.20.260.20.1.44Columnf2R4GFx2DDWaveLenread-onlycurrentLocal FRM220-2R4G card fiber2 D/D information: Wave length
1.3.6.1.4.1.4756.20.260.20.1.45Columnf2R4GFx2DDWaveLen2read-onlycurrentLocal FRM220-2R4G card fiber2 D/D information: Wave length 2
1.3.6.1.4.1.4756.20.260.20.1.46Columnf2R4GFx2DDLinkLenread-onlycurrentLocal FRM220-2R4G card fiber2 D/D information: Link length
1.3.6.1.4.1.4756.20.260.20.1.47Columnf2R4GFx2DDLenUnitread-onlycurrentLocal FRM220-2R4G card fiber2 D/D information: Length Unit
1.3.6.1.4.1.4756.20.260.20.1.48Columnf2R4GFx2DDStatusread-onlycurrentLocal FRM220-2R4G card fiber2 D/D information: Status Support
1.3.6.1.4.1.4756.20.260.20.1.49Columnf2R4GFx2DDRxSensread-onlycurrentLocal FRM220-2R4G card fiber2 D/D information: Rx Sensitivity
1.3.6.1.4.1.4756.20.260.20.1.50Columnf2R4GFx2DDTxPWRread-onlycurrentLocal FRM220-2R4G card fiber2 D/D information: Tx power
1.3.6.1.4.1.4756.20.260.20.1.51Columnf2R4GFx2DDRxPWRread-onlycurrentLocal FRM220-2R4G card fiber2 D/D information: Rx power
1.3.6.1.4.1.4756.20.260.20.1.52Columnf2R4GFx2DDTempread-onlycurrentLocal FRM220-2R4G card fiber2 D/D information: Temperature in degree C
1.3.6.1.4.1.4756.20.260.20.1.53Columnf2R4GFx2DDPWRMarginread-onlycurrentLocal FRM220-2R4G card fiber2 D/D information: Power margin
1.3.6.1.4.1.4756.20.260.20.1.54Columnf2R4GFx3DDread-onlycurrentLocal FRM220-2R4G card fiber3 Digital Diagnostic function: 0:No 1:Yes
1.3.6.1.4.1.4756.20.260.20.1.55Columnf2R4GFx3DDVendorread-onlycurrentLocal FRM220-2R4G card fiber3 D/D information: Vendor name
1.3.6.1.4.1.4756.20.260.20.1.56Columnf2R4GFx3DDPartNoread-onlycurrentLocal FRM220-2R4G card fiber3 D/D information: Vendor part number
1.3.6.1.4.1.4756.20.260.20.1.57Columnf2R4GFx3DDVendorSNread-onlycurrentLocal FRM220-2R4G card fiber3 D/D information: Vendor serial number
1.3.6.1.4.1.4756.20.260.20.1.58Columnf2R4GFx3DDFiberTyperead-onlycurrentLocal FRM220-2R4G card fiber3 D/D information: Fiber Type
1.3.6.1.4.1.4756.20.260.20.1.59Columnf2R4GFx3DDWaveLenread-onlycurrentLocal FRM220-2R4G card fiber3 D/D information: Wave length
1.3.6.1.4.1.4756.20.260.20.1.60Columnf2R4GFx3DDWaveLen2read-onlycurrentLocal FRM220-2R4G card fiber3 D/D information: Wave length 2
1.3.6.1.4.1.4756.20.260.20.1.61Columnf2R4GFx3DDLinkLenread-onlycurrentLocal FRM220-2R4G card fiber3 D/D information: Link length
1.3.6.1.4.1.4756.20.260.20.1.62Columnf2R4GFx3DDLenUnitread-onlycurrentLocal FRM220-2R4G card fiber3 D/D information: Length Unit
1.3.6.1.4.1.4756.20.260.20.1.63Columnf2R4GFx3DDStatusread-onlycurrentLocal FRM220-2R4G card fiber3 D/D information: Status Support
1.3.6.1.4.1.4756.20.260.20.1.64Columnf2R4GFx3DDRxSensread-onlycurrentLocal FRM220-2R4G card fiber3 D/D information: Rx Sensitivity
1.3.6.1.4.1.4756.20.260.20.1.65Columnf2R4GFx3DDTxPWRread-onlycurrentLocal FRM220-2R4G card fiber3 D/D information: Tx power
1.3.6.1.4.1.4756.20.260.20.1.66Columnf2R4GFx3DDRxPWRread-onlycurrentLocal FRM220-2R4G card fiber3 D/D information: Rx power
1.3.6.1.4.1.4756.20.260.20.1.67Columnf2R4GFx3DDTempread-onlycurrentLocal FRM220-2R4G card fiber3 D/D information: Temperature in degree C
1.3.6.1.4.1.4756.20.260.20.1.68Columnf2R4GFx3DDPWRMarginread-onlycurrentLocal FRM220-2R4G card fiber3 D/D information: Power margin
1.3.6.1.4.1.4756.20.270Nodef10GCards
1.3.6.1.4.1.4756.20.270.20Tablef10GTablenot-accessiblecurrentA list of local FRM220-10G card entries. The number of entries is f10G-No-L.
1.3.6.1.4.1.4756.20.270.20.1Rowf10GEntrynot-accessiblecurrentAn entry containing management information applicable to a particular local FRM220-10G card.
1.3.6.1.4.1.4756.20.270.20.1.1Columnf10GChassisIndexread-onlycurrentA unique value for each local card. It is the chassis location number.
1.3.6.1.4.1.4756.20.270.20.1.2Columnf10GSlotIndexread-onlycurrentA unique value for each local card. It is the slot location number.
1.3.6.1.4.1.4756.20.270.20.1.3Columnf10GCardHWVerread-onlycurrentLocal FRM220-10G card hardware version x.xxx
1.3.6.1.4.1.4756.20.270.20.1.4Columnf10GCardFWVerread-onlycurrentLocal FRM220-10G card firmware version x.xxx
1.3.6.1.4.1.4756.20.270.20.1.5Columnf10GCardCPLDVerread-onlycurrentLocal FRM220-10G card CPLD version x.xxx
1.3.6.1.4.1.4756.20.270.20.1.6Columnf10GCardFPGAVerread-onlycurrentLocal FRM220-10G card FPGA version x.xxx
1.3.6.1.4.1.4756.20.270.20.1.7Columnf10GModelread-onlycurrentLocal CardType: 0:FRM220-10G/SXX 1:FRM220-10G/SX 2:FRM220-10G/XX
1.3.6.1.4.1.4756.20.270.20.1.8Columnf10GDeviceActiveread-writecurrentLocal FRM220-10G card active: 0:Inactive 1:Active
1.3.6.1.4.1.4756.20.270.20.1.9Columnf10GFx1Linkread-onlycurrentLocal FRM220-10G card Fiber1 link status: 0:Down 1:Up
1.3.6.1.4.1.4756.20.270.20.1.10Columnf10GFx2Linkread-onlycurrentLocal FRM220-10G card Fiber2 link status: 0:Down 1:Up
1.3.6.1.4.1.4756.20.270.20.1.11Columnf10GFx3Linkread-onlycurrentLocal FRM220-10G card Fiber3 link status: 0:Down 1:Up
1.3.6.1.4.1.4756.20.270.20.1.12Columnf10GFx1CDRLockedread-onlycurrentLocal FRM220-10G card Fiber1 CRD Locked: 0:Not Locked 1:Locked
1.3.6.1.4.1.4756.20.270.20.1.13Columnf10GFx2CDRLockedread-onlycurrentLocal FRM220-10G card Fiber2 CRD Locked: 0:Not Locked 1:Locked
1.3.6.1.4.1.4756.20.270.20.1.14Columnf10GFx3CDRLockedread-onlycurrentLocal FRM220-10G card Fiber3 CRD Locked: 0:Not Locked 1:Locked
1.3.6.1.4.1.4756.20.270.20.1.15Columnf10GFx1LossPropagationread-writecurrentLocal FRM220-10G card Fiber1 Loss Propagation: 0:Disable 1:Enable
1.3.6.1.4.1.4756.20.270.20.1.16Columnf10GFx2andFx3LossPropagationread-writecurrentLocal FRM220-10G card Fiber2 and Fiber3 Loss Propagation: 0:Disable 1:Enable
1.3.6.1.4.1.4756.20.270.20.1.17Columnf10GFx1AlsModeread-writecurrentLocal FRM220-10G card Fiber1 Auto Laser Showdown: 0:Disable 1:Enable
1.3.6.1.4.1.4756.20.270.20.1.18Columnf10GFx2AlsModeread-writecurrentLocal FRM220-10G card Fiber2 Auto Laser Showdown: 0:Disable 1:Enable
1.3.6.1.4.1.4756.20.270.20.1.19Columnf10GFx3AlsModeread-writecurrentLocal FRM220-10G card Fiber3 Auto Laser Showdown: 0:Disable 1:Enable
1.3.6.1.4.1.4756.20.270.20.1.20Columnf10GPortResetread-writecurrentForce local FRM220-10G card to reset mode: 0:Off 1:Action
1.3.6.1.4.1.4756.20.270.20.1.21Columnf10GSetDefaultread-writecurrentLocal FRM220-10G card set to default : 0:Off 1:Action
1.3.6.1.4.1.4756.20.270.20.1.22Columnf10GSystemOKread-onlycurrentLocal FRM220-10G card system status: 0:Failure 1:Ok
1.3.6.1.4.1.4756.20.270.20.1.23Columnf10GFx1Lbsettingread-writecurrentLocal FRM220-10G card Fiber1 Loopback: 0:Off 1:On
1.3.6.1.4.1.4756.20.270.20.1.24Columnf10GFx2Lbsettingread-writecurrentLocal FRM220-10G card Fiber1 Loopback: 0:Off 1:On
1.3.6.1.4.1.4756.20.270.20.1.25Columnf10GFx3Lbsettingread-writecurrentLocal FRM220-10G card Fiber3 Loopback: 0:Off 1:On
1.3.6.1.4.1.4756.20.270.20.1.26Columnf10GLbEnableread-writecurrentLocal FRM220-10G card Loopback mode: 0:Disable 1:Enable
1.3.6.1.4.1.4756.20.270.20.1.27Columnf10GBaudRateread-writecurrentLocal FRM220-10G card BaudRate: 0:10G Ethernet 1:10G Fiber Channel 2:OC-192/STM-64 3:G.709 OTU2 4:1G Fiber Channel 5:2G Fiber Channel 6:4G Fiber Channel 7:8G F…
1.3.6.1.4.1.4756.20.270.20.1.28Columnf10GOpticFxProread-writecurrentLocal FRM220-10G card optic fiber protection: 0:Manual 1:Auto 2:Semi-Auto 3:Pri to Sec
1.3.6.1.4.1.4756.20.270.20.1.29Columnf10GActivePathread-writecurrentLocal FRM220-10G card Loopback mode: 0:Primary 1:Second
1.3.6.1.4.1.4756.20.270.20.1.30Columnf10GFx1LinkAlarmread-writecurrentLocal FRM220-10G card Fx1 Link Alarm: 0:Disalbe 1:Enable
1.3.6.1.4.1.4756.20.270.20.1.31Columnf10GFx2LinkAlarmread-writecurrentLocal FRM220-10G card Fx2 Link Alarm: 0:Disalbe 1:Enable
1.3.6.1.4.1.4756.20.270.20.1.32Columnf10GFx3LinkAlarmread-writecurrentLocal FRM220-10G card Fx3 Link Alarm: 0:Disalbe 1:Enable
1.3.6.1.4.1.4756.20.270.20.1.33Columnf10GFx1DDread-onlycurrentLocal FRM220-10G card fiber Digital Diagnostic function: 0:No 1:Yes
1.3.6.1.4.1.4756.20.270.20.1.34Columnf10GFx1DDVendorread-onlycurrentLocal FRM220-10G card fiber D/D information: Vendor name
1.3.6.1.4.1.4756.20.270.20.1.35Columnf10GFx1DDPartNoread-onlycurrentLocal FRM220-10G card fiber D/D information: Vendor part number
1.3.6.1.4.1.4756.20.270.20.1.36Columnf10GFx1DDFiberTyperead-onlycurrentLocal FRM220-10G card fiber D/D information: Fiber Type
1.3.6.1.4.1.4756.20.270.20.1.37Columnf10GFx1DDWaveLenread-onlycurrentLocal FRM220-10G card fiber D/D information: Wave length
1.3.6.1.4.1.4756.20.270.20.1.38Columnf10GFx1DDWaveLen2read-onlycurrentLocal FRM220-10G card fiber D/D information: Wave length 2
1.3.6.1.4.1.4756.20.270.20.1.39Columnf10GFx1DDLinkLenread-onlycurrentLocal FRM220-10G card fiber D/D information: Link length
1.3.6.1.4.1.4756.20.270.20.1.40Columnf10GFx1DDLenUnitread-onlycurrentLocal FRM220-10G card fiber D/D information: Length Unit
1.3.6.1.4.1.4756.20.270.20.1.41Columnf10GFx1DDStatusread-onlycurrentLocal FRM220-10G card fiber D/D information: Status Support
1.3.6.1.4.1.4756.20.270.20.1.42Columnf10GFx1DDRxSensread-onlycurrentLocal FRM220-10G card fiber D/D information: Rx Sensitivity
1.3.6.1.4.1.4756.20.270.20.1.43Columnf10GFx1DDTxPWRread-onlycurrentLocal FRM220-10G card fiber D/D information: Tx power
1.3.6.1.4.1.4756.20.270.20.1.44Columnf10GFx1DDRxPWRread-onlycurrentLocal FRM220-10G card fiber D/D information: Rx power
1.3.6.1.4.1.4756.20.270.20.1.45Columnf10GFx1DDTempread-onlycurrentLocal FRM220-10G card fiber D/D information: Temperature in degree C
1.3.6.1.4.1.4756.20.270.20.1.46Columnf10GFx1DDPWRMarginread-onlycurrentLocal FRM220-10G card fiber D/D information: Power margin
1.3.6.1.4.1.4756.20.270.20.1.47Columnf10GFx2DDread-onlycurrentLocal FRM220-10G card fiber2 Digital Diagnostic function: 0:No 1:Yes
1.3.6.1.4.1.4756.20.270.20.1.48Columnf10GFx2DDVendorread-onlycurrentLocal FRM220-10G card fiber2 D/D information: Vendor name
1.3.6.1.4.1.4756.20.270.20.1.49Columnf10GFx2DDPartNoread-onlycurrentLocal FRM220-10G card fiber2 D/D information: Vendor part number
1.3.6.1.4.1.4756.20.270.20.1.50Columnf10GFx2DDFiberTyperead-onlycurrentLocal FRM220-10G card fiber2 D/D information: Fiber Type
1.3.6.1.4.1.4756.20.270.20.1.51Columnf10GFx2DDWaveLenread-onlycurrentLocal FRM220-10G card fiber2 D/D information: Wave length
1.3.6.1.4.1.4756.20.270.20.1.52Columnf10GFx2DDWaveLen2read-onlycurrentLocal FRM220-10G card fiber2 D/D information: Wave length 2
1.3.6.1.4.1.4756.20.270.20.1.53Columnf10GFx2DDLinkLenread-onlycurrentLocal FRM220-10G card fiber2 D/D information: Link length
1.3.6.1.4.1.4756.20.270.20.1.54Columnf10GFx2DDLenUnitread-onlycurrentLocal FRM220-10G card fiber2 D/D information: Length Unit
1.3.6.1.4.1.4756.20.270.20.1.55Columnf10GFx2DDStatusread-onlycurrentLocal FRM220-10G card fiber2 D/D information: Status Support
1.3.6.1.4.1.4756.20.270.20.1.56Columnf10GFx2DDRxSensread-onlycurrentLocal FRM220-10G card fiber2 D/D information: Rx Sensitivity
1.3.6.1.4.1.4756.20.270.20.1.57Columnf10GFx2DDTxPWRread-onlycurrentLocal FRM220-10G card fiber2 D/D information: Tx power
1.3.6.1.4.1.4756.20.270.20.1.58Columnf10GFx2DDRxPWRread-onlycurrentLocal FRM220-10G card fiber2 D/D information: Rx power
1.3.6.1.4.1.4756.20.270.20.1.59Columnf10GFx2DDTempread-onlycurrentLocal FRM220-10G card fiber2 D/D information: Temperature in degree C
1.3.6.1.4.1.4756.20.270.20.1.60Columnf10GFx2DDPWRMarginread-onlycurrentLocal FRM220-10G card fiber2 D/D information: Power margin
1.3.6.1.4.1.4756.20.270.20.1.61Columnf10GFx3DDread-onlycurrentLocal FRM220-10G card fiber Digital Diagnostic function: 0:No 1:Yes
1.3.6.1.4.1.4756.20.270.20.1.62Columnf10GFx3DDVendorread-onlycurrentLocal FRM220-10G card fiber D/D information: Vendor name
1.3.6.1.4.1.4756.20.270.20.1.63Columnf10GFx3DDPartNoread-onlycurrentLocal FRM220-10G card fiber D/D information: Vendor part number
1.3.6.1.4.1.4756.20.270.20.1.64Columnf10GFx3DDFiberTyperead-onlycurrentLocal FRM220-10G card fiber D/D information: Fiber Type
1.3.6.1.4.1.4756.20.270.20.1.65Columnf10GFx3DDWaveLenread-onlycurrentLocal FRM220-10G card fiber D/D information: Wave length
1.3.6.1.4.1.4756.20.270.20.1.66Columnf10GFx3DDWaveLen2read-onlycurrentLocal FRM220-10G card fiber D/D information: Wave length 2
1.3.6.1.4.1.4756.20.270.20.1.67Columnf10GFx3DDLinkLenread-onlycurrentLocal FRM220-10G card fiber D/D information: Link length
1.3.6.1.4.1.4756.20.270.20.1.68Columnf10GFx3DDLenUnitread-onlycurrentLocal FRM220-10G card fiber D/D information: Length Unit
1.3.6.1.4.1.4756.20.270.20.1.69Columnf10GFx3DDStatusread-onlycurrentLocal FRM220-10G card fiber D/D information: Status Support
1.3.6.1.4.1.4756.20.270.20.1.70Columnf10GFx3DDRxSensread-onlycurrentLocal FRM220-10G card fiber D/D information: Rx Sensitivity
1.3.6.1.4.1.4756.20.270.20.1.71Columnf10GFx3DDTxPWRread-onlycurrentLocal FRM220-10G card fiber D/D information: Tx power
1.3.6.1.4.1.4756.20.270.20.1.72Columnf10GFx3DDRxPWRread-onlycurrentLocal FRM220-10G card fiber D/D information: Rx power
1.3.6.1.4.1.4756.20.270.20.1.73Columnf10GFx3DDTempread-onlycurrentLocal FRM220-10G card fiber D/D information: Temperature in degree C
1.3.6.1.4.1.4756.20.270.20.1.74Columnf10GFx3DDPWRMarginread-onlycurrentLocal FRM220-10G card fiber D/D information: Power margin
1.3.6.1.4.1.4756.20.270.20.1.75Columnf10GBertLineTxModeread-writecurrentLocal 10G-SXX card BERTLine Tx Mode: 0:Disable 1:Enable
1.3.6.1.4.1.4756.20.270.20.1.76Columnf10GBertLineTxPatternread-writecurrentLocal 10G-SXX card BERT Line Tx Pattern: 0:PRBS 7 1:PRBS 9 2:PRBS 23 3:PRBS 31 4:Pass-Through
1.3.6.1.4.1.4756.20.270.20.1.77Columnf10GBertLineTxPolarityread-writecurrentLocal 10G-SXX card BERT Line Tx Polarity: 0:Normal 1:invert
1.3.6.1.4.1.4756.20.270.20.1.78Columnf10GBertLineRxModeread-writecurrentLocal 10G-SXX card BERT Line Rx Mode: 0:Disable 1:Enable
1.3.6.1.4.1.4756.20.270.20.1.79Columnf10GBertLineRxPatternread-writecurrentLocal 10G-SXX card BERT Line Rx Pattern: 0:PRBS 7 1:PRBS 9 2:PRBS 23 3:PRBS 31
1.3.6.1.4.1.4756.20.270.20.1.80Columnf10GBertLineRxPolarityread-writecurrentLocal 10G-SXX card BERT Line Rx Polarity: 0:Normal 1:invert
1.3.6.1.4.1.4756.20.270.20.1.81Columnf10GBertLineRxPatternStatusread-onlycurrentLocal 10G-SXX card BERT Line Rx Pattern Status: 0:Loss 1:Sync
1.3.6.1.4.1.4756.20.270.20.1.82Columnf10GBertLineRxErrorCounterread-onlycurrentLocal 10G-SXX card BERT Line Rx Error Counter.
1.3.6.1.4.1.4756.20.270.20.1.83Columnf10GBertLineClrErrorCounterread-writecurrentLocal 10G-SXX card BERT Line Clear Rx Error counter.
1.3.6.1.4.1.4756.20.270.20.1.84Columnf10GBertClientTxModeread-writecurrentLocal 10G-SXX card BERT Client Tx Mode: 0:Disable 1:Enable
1.3.6.1.4.1.4756.20.270.20.1.85Columnf10GBertClientTxPatternread-writecurrentLocal 10G-SXX card BERT Client Tx Pattern: 0:PRBS 7 1:PRBS 9 2:PRBS 23 3:PRBS 31 4:Pass-Through
1.3.6.1.4.1.4756.20.270.20.1.86Columnf10GBertClientTxPolarityread-writecurrentLocal 10G-SXX card BERT Client Tx Polarity: 0:Normal 1:invert
1.3.6.1.4.1.4756.20.270.20.1.87Columnf10GBertClientRxModeread-writecurrentLocal 10G-SXX card BERT Client Rx Mode: 0:Disable 1:Enable
1.3.6.1.4.1.4756.20.270.20.1.88Columnf10GBertClientRxPatternread-writecurrentLocal 10G-SXX card BERT Client Rx Pattern: 0:PRBS 7 1:PRBS 9 2:PRBS 23 3:PRBS 31
1.3.6.1.4.1.4756.20.270.20.1.89Columnf10GBertClientRxPolarityread-writecurrentLocal 10G-SXX card BERT Client Rx Polarity: 0:Normal 1:invert
1.3.6.1.4.1.4756.20.270.20.1.90Columnf10GBertClientRxPatternStatusread-onlycurrentLocal 10G-SXX card BERT Client Rx Pattern Status: 0:Loss 1:Sync
1.3.6.1.4.1.4756.20.270.20.1.91Columnf10GBertClientRxErrorCounterread-onlycurrentLocal 10G-SXX card BERT Client Rx Error Counter.
1.3.6.1.4.1.4756.20.270.20.1.92Columnf10GBertClientClrErrorCounterread-writecurrentLocal 10G-SXX card BERT Client Clear Rx Error counter.
1.3.6.1.4.1.4756.20.270.20.1.93Columnf10GXFP2WaveLengthStatusread-onlycurrentLocal 10G-SXX card Tunable XFP2 Wavelength Status: 0:Normal 1:Abnormal
1.3.6.1.4.1.4756.20.270.20.1.94Columnf10GXFP3WaveLengthStatusread-onlycurrentLocal 10G-SXX card Tunable XFP3 Wavelength Status: 0:Normal 1:Abnormal
1.3.6.1.4.1.4756.20.270.20.1.95Columnf10GXFP2TemperatureStatusread-onlycurrentLocal 10G-SXX card Tunable XFP2 Temperature Status: 0:Normal 1:Abnormal
1.3.6.1.4.1.4756.20.270.20.1.96Columnf10GXFP3TemperatureStatusread-onlycurrentLocal 10G-SXX card Tunable XFP3 Temperature Status: 0:Normal 1:Abnormal
1.3.6.1.4.1.4756.20.270.20.1.97Columnf10GXFP2TemperaturAlarmread-writecurrentLocal 10G-SXX card XFP2 temperature trap. 0:Disable 1:Enable
1.3.6.1.4.1.4756.20.270.20.1.98Columnf10GXFP3TemperaturAlarmread-writecurrentLocal 10G-SXX card XFP3 temperature trap. 0:Disable 1:Enable
1.3.6.1.4.1.4756.20.270.20.1.99Columnf10GTunableXFP2Wavelengthread-writecurrentSet Tunable XFP2 Wavelength (ITU-T CH): The channel is restricted to 20 ~ 61
1.3.6.1.4.1.4756.20.270.20.1.100Columnf10GTunableXFP3Wavelengthread-writecurrentSet Tunable XFP3 Wavelength (ITU-T CH): The channel is restricted to 20 ~ 61
1.3.6.1.4.1.4756.20.270.20.1.101Columnf10GLineRxPowerStatusread-onlycurrentLocal 10G-SXX card Line Rx Power Status: 0:Normal 1:Warning 2:Alarm
1.3.6.1.4.1.4756.20.270.20.1.102Columnf10GLineRxPowerWarningThresholdread-writecurrentSet Line Rx Power Warning Threshold: Input range is from -40 to +10.
1.3.6.1.4.1.4756.20.270.20.1.103Columnf10GLineRxPowerAlarmThresholdread-writecurrentSet Line Rx Power Alarm Threshold: Input range is from -40 to +10.
1.3.6.1.4.1.4756.20.270.20.1.104Columnf10GLineRxPowerStatusAlarmread-writecurrentLocal 10G-SXX card Line Rx Power Status trap. 0:Disable 1:Enable
1.3.6.1.4.1.4756.20.270.20.1.105Columnf10GLineLosAssertAlarmread-writecurrentLocal 10G-SXX card Line LOS Assert trap. 0:Disable 1:Enable
1.3.6.1.4.1.4756.20.270.20.1.106Columnf10GPriRxPowerStatusread-onlycurrentLocal 10G-SXX card Primary Rx Power Status: 0:Normal 1:Warning 2:Alarm
1.3.6.1.4.1.4756.20.270.20.1.107Columnf10GPriRxPowerWarningThresholdread-writecurrentSet Primary Rx Power Warning Threshold: Input range is from -40 to +10.
1.3.6.1.4.1.4756.20.270.20.1.108Columnf10GPriRxPowerAlarmThresholdread-writecurrentSet Primary Rx Power Alarm Threshold: Input range is from -40 to +10.
1.3.6.1.4.1.4756.20.270.20.1.109Columnf10GPriRxPowerStatusAlarmread-writecurrentLocal 10G-SXX card Primary Rx Power Status trap. 0:Disable 1:Enable
1.3.6.1.4.1.4756.20.270.20.1.110Columnf10GPriLosAssertAlarmread-writecurrentLocal 10G-SXX card Primary LOS Assert trap. 0:Disable 1:Enable
1.3.6.1.4.1.4756.20.270.20.1.111Columnf10GSecRxPowerStatusread-onlycurrentLocal 10G-SXX card Secondary Rx Power Status: 0:Normal 1:Warning 2:Alarm
1.3.6.1.4.1.4756.20.270.20.1.112Columnf10GSecRxPowerWarningThresholdread-writecurrentSet Secondary Rx Power Warning Threshold: Input range is from -40 to +10.
1.3.6.1.4.1.4756.20.270.20.1.113Columnf10GSecRxPowerAlarmThresholdread-writecurrentSet Secondary Rx Power Alarm Threshold: Input range is from -40 to +10.
1.3.6.1.4.1.4756.20.270.20.1.114Columnf10GSecRxPowerStatusAlarmread-writecurrentLocal 10G-SXX card Secondary Rx Power Status trap. 0:Disable 1:Enable
1.3.6.1.4.1.4756.20.270.20.1.115Columnf10GSecLosAssertAlarmread-writecurrentLocal 10G-SXX card Secondary LOS Assert trap. 0:Disable 1:Enable
1.3.6.1.4.1.4756.20.270.20.1.116Columnf10GTunableXFP2read-onlycurrentLocal 10G-SXX card Tunable XFP2. 0:No 1:Yes
1.3.6.1.4.1.4756.20.270.20.1.117Columnf10GTunableXFP3read-onlycurrentLocal 10G-SXX card Tunable XFP3. 0:No 1:Yes
1.3.6.1.4.1.4756.20.280Nodef100I2ELocalCards
1.3.6.1.4.1.4756.20.280.20Tablef100I2ELocalTablenot-accessiblecurrentA list of local FRM220-10/100I2E card entries. The number of entries is f100I2E-No-L.
1.3.6.1.4.1.4756.20.280.20.1Rowf100I2ELocalEntrynot-accessiblecurrentAn entry containing management information applicable to a particular local FRM220-10/100I2E card.
1.3.6.1.4.1.4756.20.280.20.1.1Columnf100I2EChassisIndexLocalread-onlycurrentA unique value for each local card. It is the chassis location number.
1.3.6.1.4.1.4756.20.280.20.1.2Columnf100I2ESlotIndexLocalread-onlycurrentA unique value for each local card. It is the slot location number.
1.3.6.1.4.1.4756.20.280.20.1.3Columnf100I2ECardHWVerLocalread-onlycurrentLocal FRM220-10/100I-2E card hardware version x.xxx
1.3.6.1.4.1.4756.20.280.20.1.4Columnf100I2ECardFWVerLocalread-onlycurrentLocal FRM220-10/100I-2E card firmware version x.xxx
1.3.6.1.4.1.4756.20.280.20.1.5Columnf100I2ECardCPLDVerLocalread-onlycurrentLocal FRM220-10/100I-2E card CPLD version x.xxx
1.3.6.1.4.1.4756.20.280.20.1.6Columnf100I2ECardFPGAVerLocalread-onlycurrentLocal FRM220-10/100I-2E card FPGA version x.xxx
1.3.6.1.4.1.4756.20.280.20.1.7Columnf100I2EPortActiveLocalread-writecurrentLocal FRM220-10/100I-2E card active: 0:Inactive 1:Active
1.3.6.1.4.1.4756.20.280.20.1.8Columnf100I2EPortResetLocalread-writecurrentForce local FRM220-10/100I-2E card to reset mode: 0:Off 1:Action
1.3.6.1.4.1.4756.20.280.20.1.9Columnf100I2ESettoDefaultLocalread-writecurrentLocal FRM220-10/100I-2E card Set to default: 0:No action 1:Action
1.3.6.1.4.1.4756.20.280.20.1.10Columnf100I2EFxLinkLocalread-onlycurrentLocal FRM220-10/100I-2E card fiber link status: 0:Down 1:Up
1.3.6.1.4.1.4756.20.280.20.1.11Columnf100I2EFxFEFLocalread-onlycurrentLocal FRM220-10/100I-2E card fiber detected Far End Fault: 0:Off 1:Detected
1.3.6.1.4.1.4756.20.280.20.1.12Columnf100I2EFxRemoPWRAbLocalread-onlycurrentLocal FRM220-10/100I-2E card fiber Remote Power status: 0:Abnormal 1:OK
1.3.6.1.4.1.4756.20.280.20.1.13Columnf100I2EInBandManagLocalread-writecurrentLocal FRM220-10/100I-2E card manages remote: 0:Disable 1:Enable
1.3.6.1.4.1.4756.20.280.20.1.14Columnf100I2EUtp1LinkLocalread-onlycurrentLocal FRM220-10/100I-2E card UTP 1 link status: 0:Down 1:Up
1.3.6.1.4.1.4756.20.280.20.1.15Columnf100I2EUtp1NegoLocalread-writecurrentLocal FRM220-10/100I-2E card UTP 1 negotiation status: 0:Manual 1:Auto
1.3.6.1.4.1.4756.20.280.20.1.16Columnf100I2EUtp1SpeedLocalread-writecurrentLocal FRM220-10/100I-2E card UTP 1 speed: 0:10MHz 1:100MHz
1.3.6.1.4.1.4756.20.280.20.1.17Columnf100I2EUtp1DuplexLocalread-writecurrentLocal FRM220-10/100I-2E card UTP 1 duplex: 0:Half duplex mode 1:Full duplex mode
1.3.6.1.4.1.4756.20.280.20.1.18Columnf100I2EUtp1SpeedStatusLocalread-onlycurrentLocal FRM220-10/100I-2E card UTP 1 speed status: 0:10MHz 1:100MHz
1.3.6.1.4.1.4756.20.280.20.1.19Columnf100I2EUtp1DuplexStatusLocalread-onlycurrentLocal FRM220-10/100I-2E card UTP 1 duplex status: 0:Half duplex mode 1:Full duplex mode
1.3.6.1.4.1.4756.20.280.20.1.20Columnf100I2EUtp1VIDNumberLocalread-writecurrentLocal FRM220-10/100I-2E card UTP 1 VID number (1~4094)
1.3.6.1.4.1.4756.20.280.20.1.21Columnf100I2EUtp2LinkLocalread-onlycurrentLocal FRM220-10/100I-2E card UTP 2 link status: 0:Down 1:Up
1.3.6.1.4.1.4756.20.280.20.1.22Columnf100I2EUtp2NegoLocalread-writecurrentLocal FRM220-10/100I-2E card UTP 2 negotiation status: 0:Manual 1:Auto
1.3.6.1.4.1.4756.20.280.20.1.23Columnf100I2EUtp2SpeedLocalread-writecurrentLocal FRM220-10/100I-2E card UTP 2 speed: 0:10MHz 1:100MHz
1.3.6.1.4.1.4756.20.280.20.1.24Columnf100I2EUtp2DuplexLocalread-writecurrentLocal FRM220-10/100I-2E card UTP 2 duplex: 0:Half duplex mode 1:Full duplex mode
1.3.6.1.4.1.4756.20.280.20.1.25Columnf100I2EUtp2SpeedStatusLocalread-onlycurrentLocal FRM220-10/100I-2E card UTP 2 speed status: 0:10MHz 1:100MHz
1.3.6.1.4.1.4756.20.280.20.1.26Columnf100I2EUtp2DuplexStatusLocalread-onlycurrentLocal FRM220-10/100I-2E card UTP 2 duplex status: 0:Half duplex mode 1:Full duplex mode
1.3.6.1.4.1.4756.20.280.20.1.27Columnf100I2EUtp2VIDNumberLocalread-writecurrentLocal FRM220-10/100I-2E card UTP 2 VID number (1~4094)
1.3.6.1.4.1.4756.20.280.20.1.28Columnf100I2EIrl1ModeLocalread-writecurrentLocal FRM220-10/100I-2E card UTP 1 Ingress Rate Limit mode: 0:No limit 1:n x 32K 2:n x 512K
1.3.6.1.4.1.4756.20.280.20.1.29Columnf100I2EIrl1MultLocalread-writecurrentLocal FRM220-10/100I-2E card UTP 1 Ingress Rate Limit multiple: When the irlMode-L is n x 32K mode, the irlMult-L should be the value between 0 to 255; When th…
1.3.6.1.4.1.4756.20.280.20.1.30Columnf100I2EErl1ModeLocalread-writecurrentLocal FRM220-10/100I-2E card UTP 1 Egress Rate Limit mode: 0:No limit 1:n x 32K 2:n x 512K
1.3.6.1.4.1.4756.20.280.20.1.31Columnf100I2EErl1MultLocalread-writecurrentLocal FRM220-10/100I-2E card UTP 1 Egress Rate Limit multiple: When the erlMode-L is n x 32K mode, the erlMult-L should be the value between 0 to 255; When the…
1.3.6.1.4.1.4756.20.280.20.1.32Columnf100I2EIrl2ModeLocalread-writecurrentLocal FRM220-10/100I-2E card UTP 2 Ingress Rate Limit mode: 0:No limit 1:n x 32K 2:n x 512K
1.3.6.1.4.1.4756.20.280.20.1.33Columnf100I2EIrl2MultLocalread-writecurrentLocal FRM220-10/100I-2E card UTP 2 Ingress Rate Limit multiple: When the irlMode-L is n x 32K mode, the irlMult-L should be the value between 0 to 255; When th…
1.3.6.1.4.1.4756.20.280.20.1.34Columnf100I2EErl2ModeLocalread-writecurrentLocal FRM220-10/100I-2E card UTP 2 Egress Rate Limit mode: 0:No limit 1:n x 32K 2:n x 512K
1.3.6.1.4.1.4756.20.280.20.1.35Columnf100I2EErl2MultLocalread-writecurrentLocal FRM220-10/100I-2E card UTP 2 Egress Rate Limit multiple: When the erlMode-L is n x 32K mode, the erlMult-L should be the value between 0 to 255; When the…
1.3.6.1.4.1.4756.20.280.20.1.36Columnf100I2EOpModeLocalread-writecurrentLocal FRM220-10/100I-2E card operation mode: 0:Switch mode 1:Tag based VLAN mode
1.3.6.1.4.1.4756.20.280.20.1.37Columnf100I2ELfpModeLocalread-writecurrentLocal FRM220-10/100I-2E card Link Fault Pass-through mode: 0:Disable 1:Enable
1.3.6.1.4.1.4756.20.280.20.1.38Columnf100I2EAlsModeLocalread-writecurrentLocal FRM220-10/100I-2E card Auto Laser Shutdown mode: 0:Disable 1:Enable
1.3.6.1.4.1.4756.20.280.20.1.39Columnf100I2ESendFHRLocalread-writecurrentLocal FRM220-10/100I-2E card send Fiber Hardware Reset to remote: 0:No action 1:Action
1.3.6.1.4.1.4756.20.280.20.1.40Columnf100I2EFxDDLocalread-onlycurrentLocal FRM220-10/100I-2E card fiber Digital Diagnostic function: 0:No 1:Yes
1.3.6.1.4.1.4756.20.280.20.1.41Columnf100I2EDDVendorLocalread-onlycurrentLocal FRM220-10/100I-2E card fiber D/D information: Vendor name
1.3.6.1.4.1.4756.20.280.20.1.42Columnf100I2EDDPartNoLocalread-onlycurrentLocal FRM220-10/100I-2E card fiber D/D information: Vendor part number
1.3.6.1.4.1.4756.20.280.20.1.43Columnf100I2EDDFiberTypeLocalread-onlycurrentLocal FRM220-10/100I-2E card fiber D/D information: Fiber Type
1.3.6.1.4.1.4756.20.280.20.1.44Columnf100I2EDDWaveLenLocalread-onlycurrentLocal FRM220-10/100I-2E card fiber D/D information: Wave length
1.3.6.1.4.1.4756.20.280.20.1.45Columnf100I2EDDWaveLen2Localread-onlycurrentLocal FRM220-10/100I-2E card fiber D/D information: Wave length 2
1.3.6.1.4.1.4756.20.280.20.1.46Columnf100I2EDDLinkLenLocalread-onlycurrentLocal FRM220-10/100I-2E card fiber D/D information: Link length
1.3.6.1.4.1.4756.20.280.20.1.47Columnf100I2EDDLenUnitLocalread-onlycurrentLocal FRM220-10/100I-2E card fiber D/D information: Length Unit
1.3.6.1.4.1.4756.20.280.20.1.48Columnf100I2EDDStatusLocalread-onlycurrentLocal FRM220-10/100I-2E card fiber D/D information: Status Support
1.3.6.1.4.1.4756.20.280.20.1.49Columnf100I2EDDRxSensLocalread-onlycurrentLocal FRM220-10/100I-2E card fiber D/D information: Rx Sensitivity
1.3.6.1.4.1.4756.20.280.20.1.50Columnf100I2EDDTxPWRLocalread-onlycurrentLocal FRM220-10/100I-2E card fiber D/D information: Tx power
1.3.6.1.4.1.4756.20.280.20.1.51Columnf100I2EDDRxPWRLocalread-onlycurrentLocal FRM220-10/100I-2E card fiber D/D information: Rx power
1.3.6.1.4.1.4756.20.280.20.1.52Columnf100I2EDDTempLocalread-onlycurrentLocal FRM220-10/100I-2E card fiber D/D information: Temperature in degree C
1.3.6.1.4.1.4756.20.280.20.1.53Columnf100I2EDDPWRMarginLocalread-onlycurrentLocal FRM220-10/100I-2E card fiber D/D information: Power margin
1.3.6.1.4.1.4756.20.280.20.1.54Columnf100I2EDDPWRLossLocalread-onlycurrentLocal FRM220-10/100I-2E card fiber D/D information: Power loss
1.3.6.1.4.1.4756.20.281Nodef100I2ERemoteCards
1.3.6.1.4.1.4756.20.281.20Tablef100I2ERemoteTablenot-accessiblecurrentA list of remote FRM220-10/100I-2E card entries. The number of entries is f100I2E-NoRemote.
1.3.6.1.4.1.4756.20.281.20.1Rowf100I2ERemoteEntrynot-accessiblecurrentAn entry containing management information applicable to a particular remote FRM220-10/100I-2E card.
1.3.6.1.4.1.4756.20.281.20.1.1Columnf100I2EChassisIndexRemoteread-onlycurrentA unique value for each local card. It is the chassis location number.
1.3.6.1.4.1.4756.20.281.20.1.2Columnf100I2ESlotIndexRemoteread-onlycurrentA unique value for each local card. It is the slot location number.
1.3.6.1.4.1.4756.20.281.20.1.3Columnf100I2ECardHWVerRemoteread-onlycurrentRemote FRM220-10/100I-2E card hardware version x.xxx
1.3.6.1.4.1.4756.20.281.20.1.4Columnf100I2ECardFWVerRemoteread-onlycurrentRemote FRM220-10/100I-2E card firmware version x.xxx
1.3.6.1.4.1.4756.20.281.20.1.5Columnf100I2ECardCPLDVerRemoteread-onlycurrentRemote FRM220-10/100I-2E card CPLD version x.xxx
1.3.6.1.4.1.4756.20.281.20.1.6Columnf100I2ECardFPGAVerRemoteread-onlycurrentRemote FRM220-10/100I-2E card FPGA version x.xxx
1.3.6.1.4.1.4756.20.281.20.1.7Columnf100I2EPortActiveRemoteread-onlycurrentRemote FRM220-10/100I-2E card active: 0:Inactive 1:Active
1.3.6.1.4.1.4756.20.281.20.1.8Columnf100I2EPortResetRemoteread-writecurrentForce local FRM220-10/100I-2E card to reset mode: 0:Off 1:Action
1.3.6.1.4.1.4756.20.281.20.1.9Columnf100I2ESettoDefaultRemoteread-writecurrentRemote FRM220-10/100I-2E card Set to default: 0:No action 1:Action
1.3.6.1.4.1.4756.20.281.20.1.10Columnf100I2EFxLinkRemoteread-onlycurrentRemote FRM220-10/100I-2E card fiber link status: 0:Down 1:Up
1.3.6.1.4.1.4756.20.281.20.1.11Columnf100I2EFxFEFRemoteread-onlycurrentRemote FRM220-10/100I-2E card fiber detected Far End Fault: 0:Off 1:Detected
1.3.6.1.4.1.4756.20.281.20.1.12Columnf100I2EFxRemoPWRAbRemoteread-onlycurrentRemote FRM220-10/100I-2E card fiber Remote Power status: 0:Abnormal 1:OK
1.3.6.1.4.1.4756.20.281.20.1.13Columnf100I2EUtp1LinkRemoteread-onlycurrentRemote FRM220-10/100I-2E card UTP 1 link status: 0:Down 1:Up
1.3.6.1.4.1.4756.20.281.20.1.14Columnf100I2EUtp1NegoRemoteread-writecurrentRemote FRM220-10/100I-2E card UTP 1 negotiation status: 0:Manual 1:Auto
1.3.6.1.4.1.4756.20.281.20.1.15Columnf100I2EUtp1SpeedRemoteread-writecurrentRemote FRM220-10/100I-2E card UTP 1 speed: 0:10MHz 1:100MHz
1.3.6.1.4.1.4756.20.281.20.1.16Columnf100I2EUtp1DuplexRemoteread-writecurrentRemote FRM220-10/100I-2E card UTP 1 duplex: 0:Half duplex mode 1:Full duplex mode
1.3.6.1.4.1.4756.20.281.20.1.17Columnf100I2EUtp1SpeedStatusRemoteread-onlycurrentRemote FRM220-10/100I-2E card UTP 1 speed status: 0:10MHz 1:100MHz
1.3.6.1.4.1.4756.20.281.20.1.18Columnf100I2EUtp1DuplexStatusRemoteread-onlycurrentRemote FRM220-10/100I-2E card UTP 1 duplex status: 0:Half duplex mode 1:Full duplex mode
1.3.6.1.4.1.4756.20.281.20.1.19Columnf100I2EUtp1VIDNumberRemoteread-writecurrentRemote FRM220-10/100I-2E card UTP 1 VID number (1~4094)
1.3.6.1.4.1.4756.20.281.20.1.20Columnf100I2EUtp2LinkRemoteread-onlycurrentRemote FRM220-10/100I-2E card UTP 2 link status: 0:Down 1:Up
1.3.6.1.4.1.4756.20.281.20.1.21Columnf100I2EUtp2NegoRemoteread-writecurrentRemote FRM220-10/100I-2E card UTP 2 negotiation status: 0:Manual 1:Auto
1.3.6.1.4.1.4756.20.281.20.1.22Columnf100I2EUtp2SpeedRemoteread-writecurrentRemote FRM220-10/100I-2E card UTP 2 speed: 0:10MHz 1:100MHz
1.3.6.1.4.1.4756.20.281.20.1.23Columnf100I2EUtp2DuplexRemoteread-writecurrentRemote FRM220-10/100I-2E card UTP 2 duplex: 0:Half duplex mode 1:Full duplex mode
1.3.6.1.4.1.4756.20.281.20.1.24Columnf100I2EUtp2SpeedStatusRemoteread-onlycurrentRemote FRM220-10/100I-2E card UTP 2 speed status: 0:10MHz 1:100MHz
1.3.6.1.4.1.4756.20.281.20.1.25Columnf100I2EUtp2DuplexStatusRemoteread-onlycurrentRemote FRM220-10/100I-2E card UTP 2 duplex status: 0:Half duplex mode 1:Full duplex mode
1.3.6.1.4.1.4756.20.281.20.1.26Columnf100I2EUtp2VIDNumberRemoteread-writecurrentRemote FRM220-10/100I-2E card UTP 2 VID number (1~4094)
1.3.6.1.4.1.4756.20.281.20.1.27Columnf100I2EIrl1ModeRemoteread-writecurrentRemote FRM220-10/100I-2E card UTP 1 Ingress Rate Limit mode: 0:No limit 1:n x 32K 2:n x 512K
1.3.6.1.4.1.4756.20.281.20.1.28Columnf100I2EIrl1MultRemoteread-writecurrentRemote FRM220-10/100I-2E card UTP 1 Ingress Rate Limit multiple: When the irlMode-L is n x 32K mode, the irlMult-L should be the value between 0 to 255; When t…
1.3.6.1.4.1.4756.20.281.20.1.29Columnf100I2EErl1ModeRemoteread-writecurrentRemote FRM220-10/100I-2E card UTP 1 Egress Rate Limit mode: 0:No limit 1:n x 32K 2:n x 512K
1.3.6.1.4.1.4756.20.281.20.1.30Columnf100I2EErl1MultRemoteread-writecurrentRemote FRM220-10/100I-2E card UTP 1 Egress Rate Limit multiple: When the erlMode-L is n x 32K mode, the erlMult-L should be the value between 0 to 255; When th…
1.3.6.1.4.1.4756.20.281.20.1.31Columnf100I2EIrl2ModeRemoteread-writecurrentRemote FRM220-10/100I-2E card UTP 2 Ingress Rate Limit mode: 0:No limit 1:n x 32K 2:n x 512K
1.3.6.1.4.1.4756.20.281.20.1.32Columnf100I2EIrl2MultRemoteread-writecurrentRemote FRM220-10/100I-2E card UTP 2 Ingress Rate Limit multiple: When the irlMode-L is n x 32K mode, the irlMult-L should be the value between 0 to 255; When t…
1.3.6.1.4.1.4756.20.281.20.1.33Columnf100I2EErl2ModeRemoteread-writecurrentRemote FRM220-10/100I-2E card UTP 2 Egress Rate Limit mode: 0:No limit 1:n x 32K 2:n x 512K
1.3.6.1.4.1.4756.20.281.20.1.34Columnf100I2EErl2MultRemoteread-writecurrentRemote FRM220-10/100I-2E card UTP 2 Egress Rate Limit multiple: When the erlMode-L is n x 32K mode, the erlMult-L should be the value between 0 to 255; When th…
1.3.6.1.4.1.4756.20.281.20.1.35Columnf100I2EOpModeRemoteread-writecurrentRemote FRM220-10/100I-2E card operation mode: 0:Switch mode 1:Tag based VLAN mode
1.3.6.1.4.1.4756.20.281.20.1.36Columnf100I2ELfpModeRemoteread-writecurrentRemote FRM220-10/100I-2E card Link Fault Pass-through mode: 0:Disable 1:Enable
1.3.6.1.4.1.4756.20.281.20.1.37Columnf100I2EAlsModeRemoteread-writecurrentRemote FRM220-10/100I-2E card Auto Laser Shutdown mode: 0:Disable 1:Enable
1.3.6.1.4.1.4756.20.281.20.1.38Columnf100I2EFhrModeRemoteread-writecurrentRemote 10/100I-2E card accepts Fiber Hardware Reset mode: 0:Disable 1:Enable
1.3.6.1.4.1.4756.20.281.20.1.39Columnf100I2EFxDDRemoteread-onlycurrentRemote FRM220-10/100I-2E card fiber Digital Diagnostic function: 0:No 1:Yes
1.3.6.1.4.1.4756.20.281.20.1.40Columnf100I2EDDVendorRemoteread-onlycurrentRemote FRM220-10/100I-2E card fiber D/D information: Vendor name
1.3.6.1.4.1.4756.20.281.20.1.41Columnf100I2EDDPartNoRemoteread-onlycurrentRemote FRM220-10/100I-2E card fiber D/D information: Vendor part number
1.3.6.1.4.1.4756.20.281.20.1.42Columnf100I2EDDFiberTypeRemoteread-onlycurrentRemote FRM220-10/100I-2E card fiber D/D information: Fiber Type
1.3.6.1.4.1.4756.20.281.20.1.43Columnf100I2EDDWaveLenRemoteread-onlycurrentRemote FRM220-10/100I-2E card fiber D/D information: Wave length
1.3.6.1.4.1.4756.20.281.20.1.44Columnf100I2EDDWaveLen2Remoteread-onlycurrentRemote FRM220-10/100I-2E card fiber D/D information: Wave length 2
1.3.6.1.4.1.4756.20.281.20.1.45Columnf100I2EDDLinkLenRemoteread-onlycurrentRemote FRM220-10/100I-2E card fiber D/D information: Link length
1.3.6.1.4.1.4756.20.281.20.1.46Columnf100I2EDDLenUnitRemoteread-onlycurrentRemote FRM220-10/100I-2E card fiber D/D information: Length Unit
1.3.6.1.4.1.4756.20.281.20.1.47Columnf100I2EDDStatusRemoteread-onlycurrentRemote FRM220-10/100I-2E card fiber D/D information: Status Support
1.3.6.1.4.1.4756.20.281.20.1.48Columnf100I2EDDRxSensRemoteread-onlycurrentRemote FRM220-10/100I-2E card fiber D/D information: Rx Sensitivity
1.3.6.1.4.1.4756.20.281.20.1.49Columnf100I2EDDTxPWRRemoteread-onlycurrentRemote FRM220-10/100I-2E card fiber D/D information: Tx power
1.3.6.1.4.1.4756.20.281.20.1.50Columnf100I2EDDRxPWRRemoteread-onlycurrentRemote FRM220-10/100I-2E card fiber D/D information: Rx power
1.3.6.1.4.1.4756.20.281.20.1.51Columnf100I2EDDTempRemoteread-onlycurrentRemote FRM220-10/100I-2E card fiber D/D information: Temperature in degree C
1.3.6.1.4.1.4756.20.281.20.1.52Columnf100I2EDDPWRMarginRemoteread-onlycurrentRemote FRM220-10/100I-2E card fiber D/D information: Power margin
1.3.6.1.4.1.4756.20.281.20.1.53Columnf100I2EDDPWRLossRemoteread-onlycurrentRemote FRM220-10/100I-2E card fiber D/D information: Power loss
1.3.6.1.4.1.4756.20.290NodefswCards
1.3.6.1.4.1.4756.20.290.20TablefswTablenot-accessiblecurrentA list of local FRM220-FSW103 card entries. The number of entries is fsw-No-L.
1.3.6.1.4.1.4756.20.290.20.1RowfswEntrynot-accessiblecurrentAn entry containing management information applicable to a particular local FRM220-FSW103 card.
1.3.6.1.4.1.4756.20.290.20.1.1ColumnfswChassisIndexread-onlycurrentA unique value for each local card. It is the chassis location number.
1.3.6.1.4.1.4756.20.290.20.1.2ColumnfswSlotIndexread-onlycurrentA unique value for each local card. It is the slot location number.
1.3.6.1.4.1.4756.20.290.20.1.3ColumnfswCardHWVerread-onlycurrentLocal FRM220-FSW103 card hardware version x.xxx
1.3.6.1.4.1.4756.20.290.20.1.4ColumnfswCardFWVerread-onlycurrentLocal FRM220-FSW103 card firmware version x.xxx
1.3.6.1.4.1.4756.20.290.20.1.5ColumnfswCardCPLDVerread-onlycurrentLocal FRM220-FSW103 card CPLD version x.xxx
1.3.6.1.4.1.4756.20.290.20.1.6ColumnfswCardFPGAVerread-onlycurrentLocal FRM220-FSW103 card FPGA version x.xxx
1.3.6.1.4.1.4756.20.290.20.1.7ColumnfswDeviceActiveread-writecurrentLocal FRM220-FSW103 card active: 0:Disable 1:Enable
1.3.6.1.4.1.4756.20.290.20.1.8ColumnfswFxLinkread-onlycurrentLocal FRM220-FSW103 card fiber link status: 0:Down 1:Up
1.3.6.1.4.1.4756.20.290.20.1.9ColumnfswFxLossread-onlycurrentLocal FRM220-FSW103 card fiber loss status: 0:No 1:Yes
1.3.6.1.4.1.4756.20.290.20.1.10ColumnfswPortResetread-writecurrentForce local FRM220-FSW103 card to reset mode: 0:Off 1:Action
1.3.6.1.4.1.4756.20.290.20.1.11ColumnfswSettoDefaultread-writecurrentForce local FRM220-FSW103 card set to default: 0:Off 1:Action
1.3.6.1.4.1.4756.20.290.20.1.12ColumnfswAlsModeread-writecurrentLocal FRM220-FSW103 card Auto Laser Shutdown mode: 0:Disable 1:Enable
1.3.6.1.4.1.4756.20.290.20.1.13ColumnfswUtp1Linkread-onlycurrentLocal FRM220-FSW103 card UTP 1 link status: 0:Down 1:Up
1.3.6.1.4.1.4756.20.290.20.1.14ColumnfswUtp1Activeread-writecurrentLocal FRM220-FSW103 card UTP 1 port active: 0:Disable 1:Enable
1.3.6.1.4.1.4756.20.290.20.1.15ColumnfswUtp1Negoread-writecurrentLocal FRM220-FSW103 card UTP 1 negotiation: 0:Manual 1:Auto
1.3.6.1.4.1.4756.20.290.20.1.16ColumnfswUtp1Speedread-writecurrentLocal FRM220-FSW103 card UTP 1 speed: 0:10M 1:100M
1.3.6.1.4.1.4756.20.290.20.1.17ColumnfswUtp1Duplexread-writecurrentLocal FRM220-FSW103 card UTP 1 duplex: 0:Half duplex mode 1:Full duplex mode
1.3.6.1.4.1.4756.20.290.20.1.18ColumnfswUtp1SpeedSTSread-onlycurrentLocal FRM220-FSW103 card UTP 1 speed status: 0:10M 1:100M
1.3.6.1.4.1.4756.20.290.20.1.19ColumnfswUtp1DuplexSTSread-onlycurrentLocal FRM220-FSW103 card UTP 1 duplex status: 0:Half duplex mode 1:Full duplex mode
1.3.6.1.4.1.4756.20.290.20.1.20ColumnfswUtp2Linkread-onlycurrentLocal FRM220-FSW103 card UTP 2 link status: 0:Down 1:Up
1.3.6.1.4.1.4756.20.290.20.1.21ColumnfswUtp2Activeread-writecurrentLocal FRM220-FSW103 card UTP 2 port active: 0:Disable 1:Enable
1.3.6.1.4.1.4756.20.290.20.1.22ColumnfswUtp2Negoread-writecurrentLocal FRM220-FSW103 card UTP 2 negotiation: 0:Manual 1:Auto
1.3.6.1.4.1.4756.20.290.20.1.23ColumnfswUtp2Speedread-writecurrentLocal FRM220-FSW103 card UTP 2 speed: 0:10M 1:100M
1.3.6.1.4.1.4756.20.290.20.1.24ColumnfswUtp2Duplexread-writecurrentLocal FRM220-FSW103 card UTP 2 duplex: 0:Half duplex mode 1:Full duplex mode
1.3.6.1.4.1.4756.20.290.20.1.25ColumnfswUtp2SpeedSTSread-onlycurrentLocal FRM220-FSW103 card UTP 2 speed status: 0:10M 1:100M
1.3.6.1.4.1.4756.20.290.20.1.26ColumnfswUtp2DuplexSTSread-onlycurrentLocal FRM220-FSW103 card UTP 2 duplex status: 0:Half duplex mode 1:Full duplex mode
1.3.6.1.4.1.4756.20.290.20.1.27ColumnfswUtp3Linkread-onlycurrentLocal FRM220-FSW103 card UTP 3 link status: 0:Down 1:Up
1.3.6.1.4.1.4756.20.290.20.1.28ColumnfswUtp3Activeread-writecurrentLocal FRM220-FSW103 card UTP 3 port active: 0:Disable 1:Enable
1.3.6.1.4.1.4756.20.290.20.1.29ColumnfswUtp3Negoread-writecurrentLocal FRM220-FSW103 card UTP 3 negotiation: 0:Manual 1:Auto
1.3.6.1.4.1.4756.20.290.20.1.30ColumnfswUtp3Speedread-writecurrentLocal FRM220-FSW103 card UTP 3 speed: 0:10M 1:100M
1.3.6.1.4.1.4756.20.290.20.1.31ColumnfswUtp3Duplexread-writecurrentLocal FRM220-FSW103 card UTP 3 duplex: 0:Half duplex mode 1:Full duplex mode
1.3.6.1.4.1.4756.20.290.20.1.32ColumnfswUtp3SpeedSTSread-onlycurrentLocal FRM220-FSW103 card UTP 3 speed status: 0:10M 1:100M
1.3.6.1.4.1.4756.20.290.20.1.33ColumnfswUtp3DuplexSTSread-onlycurrentLocal FRM220-FSW103 card UTP 3 duplex status: 0:Half duplex mode 1:Full duplex mode
1.3.6.1.4.1.4756.20.290.20.1.34ColumnfswFxDDread-onlycurrentLocal FRM220-FSW103 card fiber Digital Diagnostic function: 0:No 1:Yes
1.3.6.1.4.1.4756.20.290.20.1.35ColumnfswDDVendorread-onlycurrentLocal FRM220-FSW103 card fiber D/D information: Vendor name
1.3.6.1.4.1.4756.20.290.20.1.36ColumnfswDDPartNoread-onlycurrentLocal FRM220-FSW103 card fiber D/D information: Vendor part number
1.3.6.1.4.1.4756.20.290.20.1.37ColumnfswDDFiberTyperead-onlycurrentLocal FRM220-FSW103 card fiber D/D information: Fiber Type
1.3.6.1.4.1.4756.20.290.20.1.38ColumnfswDDWaveLenread-onlycurrentLocal FRM220-FSW103 card fiber D/D information: Wave length
1.3.6.1.4.1.4756.20.290.20.1.39ColumnfswDDWaveLen2read-onlycurrentLocal FRM220-FSW103 card fiber D/D information: Wave length 2
1.3.6.1.4.1.4756.20.290.20.1.40ColumnfswDDLinkLenread-onlycurrentLocal FRM220-FSW103 card fiber D/D information: Link length
1.3.6.1.4.1.4756.20.290.20.1.41ColumnfswDDLenUnitread-onlycurrentLocal FRM220-FSW103 card fiber D/D information: Length Unit
1.3.6.1.4.1.4756.20.290.20.1.42ColumnfswDDStatusread-onlycurrentLocal FRM220-FSW103 card fiber D/D information: Status Support
1.3.6.1.4.1.4756.20.290.20.1.43ColumnfswDDRxSensread-onlycurrentLocal FRM220-FSW103 card fiber D/D information: Rx Sensitivity
1.3.6.1.4.1.4756.20.290.20.1.44ColumnfswDDTxPWRread-onlycurrentLocal FRM220-FSW103 card fiber D/D information: Tx power
1.3.6.1.4.1.4756.20.290.20.1.45ColumnfswDDRxPWRread-onlycurrentLocal FRM220-FSW103 card fiber D/D information: Rx power
1.3.6.1.4.1.4756.20.290.20.1.46ColumnfswDDTempread-onlycurrentLocal FRM220-FSW103 card fiber D/D information: Temperature in degree C
1.3.6.1.4.1.4756.20.290.20.1.47ColumnfswDDPWRMarginread-onlycurrentLocal FRM220-FSW103 card fiber D/D information: Power margin
1.3.6.1.4.1.4756.20.300Nodef1000EASXLocalCards
1.3.6.1.4.1.4756.20.300.40Tablef1000EASXLocalTablenot-accessiblecurrentA list of local 1000EAS/X card entries.
1.3.6.1.4.1.4756.20.300.40.1Rowf1000EASXLocalEntrynot-accessiblecurrentAn entry containing management information applicable to a particular local f1000EASX card.
1.3.6.1.4.1.4756.20.300.40.1.1Columnf1000EASXChassisIndexLocalread-onlycurrentA unique value for each chassis ID. For CH20, it is the chassis ID. For CH08, it is always 0.
1.3.6.1.4.1.4756.20.300.40.1.2Columnf1000EASXSlotIndexLocalread-onlycurrentA unique value for each local card. It is the slot location number.
1.3.6.1.4.1.4756.20.300.40.1.3Columnf1000EASXCardHWVerLocalread-onlycurrentLocal device card hardware version x.xxx
1.3.6.1.4.1.4756.20.300.40.1.4Columnf1000EASXCardFWVerLocalread-onlycurrentLocal device card firmware version x.xxx
1.3.6.1.4.1.4756.20.300.40.1.5Columnf1000EASXCardCPLDVerLocalread-onlycurrentLocal device card CPLD version x.xxx
1.3.6.1.4.1.4756.20.300.40.1.6Columnf1000EASXCardFPGAVerLocalread-onlycurrentLocal device card FPGA version x.xxx
1.3.6.1.4.1.4756.20.300.40.1.7Columnf1000EASXModelLocalread-onlycurrentLocal 1000EAS/X Serial Type
1.3.6.1.4.1.4756.20.300.40.1.8Columnf1000EASXFiber1LinkLocalread-onlycurrentLocal device card fiber port 1 link status: 0:Down 1:Up
1.3.6.1.4.1.4756.20.300.40.1.9Columnf1000EASXFiber1OAMLoopedLocalread-onlycurrentLocal device card fiber port 1 OAM looped: 0:Off 1:on
1.3.6.1.4.1.4756.20.300.40.1.10Columnf1000EASXFiber1LBTestLocalread-writecurrentForce remote device card to do fiber port 1 LoopBack testing: 0:Off 1:Action
1.3.6.1.4.1.4756.20.300.40.1.11Columnf1000EASXFiber1OAMRLBStatusLocalread-onlycurrentRemote device card fiber port 1 LoopBack testing status: 0:Off 1:Ok 2:Fail
1.3.6.1.4.1.4756.20.300.40.1.12Columnf1000EASXFiber1RemoPwrAbLocalread-onlycurrentLocal device card fiber port 1 Remote Power status: 0:Abnormal 1:OK 2:None
1.3.6.1.4.1.4756.20.300.40.1.13Columnf1000EASXFiber1IngressRateLocalread-writecurrentLocal device card fiber 1 Ingress Rate Limit: 0 = Unlimit input format: 64k(K),100m(M),100 If doesn't input the unit, the default was Mega. Limite Rate : 64K ~…
1.3.6.1.4.1.4756.20.300.40.1.14Columnf1000EASXFiber1EgressRateLocalread-writecurrentLocal device card fiber 1 Egress Rate Limit: 0 = Unlimit input format: 64k(K),100m(M),100 If doesn't input the unit, the default was Mega. Limite Rate : 64K ~ …
1.3.6.1.4.1.4756.20.300.40.1.15Columnf1000EASXFiber2LinkLocalread-onlycurrentLocal device card fiber port 2 link status: 0:Down 1:Up
1.3.6.1.4.1.4756.20.300.40.1.16Columnf1000EASXFiber2OAMLoopedLocalread-onlycurrentLocal device card fiber port 2 OAM looped: 0:Off 1:on
1.3.6.1.4.1.4756.20.300.40.1.17Columnf1000EASXFiber2LBTestLocalread-writecurrentForce remote device card to do fiber port 2 LoopBack testing: 0:Off 1:Action
1.3.6.1.4.1.4756.20.300.40.1.18Columnf1000EASXFiber2OAMRLBStatusLocalread-onlycurrentRemote device card fiber port 1 LoopBack testing status: 0:Off 1:Ok 2:Fail
1.3.6.1.4.1.4756.20.300.40.1.19Columnf1000EASXFiber2RemoPwrAbLocalread-onlycurrentLocal device card fiber port 2 Remote Power status: 0:Abnormal 1:OK 2:None
1.3.6.1.4.1.4756.20.300.40.1.20Columnf1000EASXFiber2IngressRateLocalread-writecurrentLocal device card fiber 2 Ingress Rate Limit: 0 = Unlimit input format: 64k(K),100m(M),100 If doesn't input the unit, the default was Mega. Limite Rate : 64K ~…
1.3.6.1.4.1.4756.20.300.40.1.21Columnf1000EASXFiber2EgressRateLocalread-writecurrentLocal device card fiber 2 Egress Rate Limit: 0 = Unlimit input format: 64k(K),100m(M),100 If doesn't input the unit, the default was Mega. Limite Rate : 64K ~ …
1.3.6.1.4.1.4756.20.300.40.1.22Columnf1000EASXUtp3LinkLocalread-onlycurrentLocal device card UTP port 3 link status: 0:Down 1:Up
1.3.6.1.4.1.4756.20.300.40.1.23Columnf1000EASXUtp3NegoLocalread-writecurrentLocal device card UTP port 3 negotiation status: 0:Manual 1:Auto
1.3.6.1.4.1.4756.20.300.40.1.24Columnf1000EASXUtp3SpeedLocalread-writecurrentLocal device card UTP port 3 speed setting: 0:10 Base-T 1:100 Base-TX 2:1000 Base-TX
1.3.6.1.4.1.4756.20.300.40.1.25Columnf1000EASXUtp3DuplexLocalread-writecurrentLocal device card UTP port 3 duplex setting: 0:Half duplex mode 1:Full duplex mode
1.3.6.1.4.1.4756.20.300.40.1.26Columnf1000EASXUtp3SpeedStatusLocalread-onlycurrentLocal device card UTP port 3 speed status: 0:10 Base-T 1:100 Base-TX 2:1000 Base-TX
1.3.6.1.4.1.4756.20.300.40.1.27Columnf1000EASXUtp3DuplexStatusLocalread-onlycurrentLocal device card UTP port 3 duplex status: 0:Half duplex mode 1:Full duplex mode
1.3.6.1.4.1.4756.20.300.40.1.28Columnf1000EASXUtp3IngressRateLocalread-writecurrentLocal device card utp 3 Ingress Rate Limit: 0 = Unlimit input format: 64k(K),100m(M),100 If doesn't input the unit, the default was Mega. Limite Rate : 64K ~ 9…
1.3.6.1.4.1.4756.20.300.40.1.29Columnf1000EASXUtp3EgressRateLocalread-writecurrentLocal device card utp 3 Egress Rate Limit: 0 = Unlimit input format: 64k(K),100m(M),100 If doesn't input the unit, the default was Mega. Limite Rate : 64K ~ 99…
1.3.6.1.4.1.4756.20.300.40.1.30Columnf1000EASXUtp4LinkLocalread-onlycurrentLocal device card UTP port 4 link status: 0:Down 1:Up
1.3.6.1.4.1.4756.20.300.40.1.31Columnf1000EASXUtp4NegoLocalread-writecurrentLocal device card UTP port 4 negotiation status: 0:Manual 1:Auto
1.3.6.1.4.1.4756.20.300.40.1.32Columnf1000EASXUtp4SpeedLocalread-writecurrentLocal device card UTP port 4 speed setting: 0:10 Base-T 1:100 Base-TX 2:1000 Base-TX
1.3.6.1.4.1.4756.20.300.40.1.33Columnf1000EASXUtp4DuplexLocalread-writecurrentLocal device card UTP port 4 duplex setting: 0:Half duplex mode 1:Full duplex mode
1.3.6.1.4.1.4756.20.300.40.1.34Columnf1000EASXUtp4SpeedStatusLocalread-onlycurrentLocal device card UTP port 4 speed status: 0:10 Base-T 1:100 Base-TX 2:1000 Base-TX
1.3.6.1.4.1.4756.20.300.40.1.35Columnf1000EASXUtp4DuplexStatusLocalread-onlycurrentLocal device card UTP port 4 duplex status: 0:Half duplex mode 1:Full duplex mode
1.3.6.1.4.1.4756.20.300.40.1.36Columnf1000EASXUtp4IngressRateLocalread-writecurrentLocal device card utp 4 Ingress Rate Limit: 0 = Unlimit input format: 64k(K),100m(M),100 If doesn't input the unit, the default was Mega. Limite Rate : 64K ~ 9…
1.3.6.1.4.1.4756.20.300.40.1.37Columnf1000EASXUtp4EgressRateLocalread-writecurrentLocal device card utp 4 Egress Rate Limit: 0 = Unlimit input format: 64k(K),100m(M),100 If doesn't input the unit, the default was Mega. Limite Rate : 64K ~ 99…
1.3.6.1.4.1.4756.20.300.40.1.38Columnf1000EASXDeviceActiveLocalread-writecurrentLocal device card active mode: (It is read-only in local device.) 0:Disable 1:Enable
1.3.6.1.4.1.4756.20.300.40.1.39Columnf1000EASXDeviceResetLocalread-writecurrentForce local device card to reset mode: 0:Off 1:Action
1.3.6.1.4.1.4756.20.300.40.1.40Columnf1000EASXFiber1ActiveLocalread-writecurrentLocal device fiber port 1 active mode: 0:Disable 1:Enable
1.3.6.1.4.1.4756.20.300.40.1.41Columnf1000EASXFiber2ActiveLocalread-writecurrentLocal device fiber port 2 active mode: 0:Disable 1:Enable
1.3.6.1.4.1.4756.20.300.40.1.42Columnf1000EASXUtp3ActiveLocalread-writecurrentLocal device UTP port 3 active mode: 0:Disable 1:Enable
1.3.6.1.4.1.4756.20.300.40.1.43Columnf1000EASXUtp4ActiveLocalread-writecurrentLocal device UTP port 4 active mode: 0:Disable 1:Enable
1.3.6.1.4.1.4756.20.300.40.1.44Columnf1000EASXOamChAModeLocalread-writecurrentLocal device OAM Channel A mode: 0:Disable 1:passive 2:Active
1.3.6.1.4.1.4756.20.300.40.1.45Columnf1000EASXOamChBModeLocalread-writecurrentLocal device OAM Channel B mode: 0:Disable 1:passive 2:Active
1.3.6.1.4.1.4756.20.300.40.1.46Columnf1000EASXOamMaxPDUsLocalread-writecurrentLocal device OAM max OAMPDU size: 60-1518 Octets
1.3.6.1.4.1.4756.20.300.40.1.47Columnf1000EASXFiber1AlsLocalread-writecurrentLocal device card port 1 Auto Laser Shutdown mode: 0:Disable 1:Enable
1.3.6.1.4.1.4756.20.300.40.1.48Columnf1000EASXFiber2AlsLocalread-writecurrentLocal device card port 2 Auto Laser Shutdown mode: 0:Disable 1:Enable
1.3.6.1.4.1.4756.20.300.40.1.49Columnf1000EASXPauseFrameLocalread-writecurrentLocal device card pause frame mode: 0:Disable 1:Enable
1.3.6.1.4.1.4756.20.300.40.1.50Columnf1000EASXSendFHRtoALocalread-writecurrentLocal device card port 1 send Fiber Hardware Reset to remote: 0:No action 1:Action
1.3.6.1.4.1.4756.20.300.40.1.51Columnf1000EASXSendFHRtoBLocalread-writecurrentLocal device card port 2 send Fiber Hardware Reset to remote: 0:No action 1:Action
1.3.6.1.4.1.4756.20.300.40.1.52Columnf1000EASXFiber1LLFDepLogiLocalread-writecurrentLocal device card port 1 Link Loss Forwarding depends boolean logic: 0:and 1:or
1.3.6.1.4.1.4756.20.300.40.1.53Columnf1000EASXFiber1LLFDepPort2Localread-writecurrentLocal device card port 1 Link Loss Forwarding depends on port 2 Fiber Rx link: 0:don't care 1:selected
1.3.6.1.4.1.4756.20.300.40.1.54Columnf1000EASXFiber1LLFDepPort3Localread-writecurrentLocal device card port 1 Link Loss Forwarding depends on port 3 Ethernet Rx link: 0:don't care 1:selected
1.3.6.1.4.1.4756.20.300.40.1.55Columnf1000EASXFiber1LLFDepPort4Localread-writecurrentLocal device card port 1 Link Loss Forwarding depends on port 4 Ethernet Rx link: 0:don't care 1:selected
1.3.6.1.4.1.4756.20.300.40.1.56Columnf1000EASXFiber2LLFDepLogiLocalread-writecurrentLocal device card port 2 Link Loss Forwarding depends boolean logic: 0:and 1:or
1.3.6.1.4.1.4756.20.300.40.1.57Columnf1000EASXFiber2LLFDepPort1Localread-writecurrentLocal device card port 2 Link Loss Forwarding depends on port 1 Fiber Rx link: 0:don't care 1:selected
1.3.6.1.4.1.4756.20.300.40.1.58Columnf1000EASXFiber2LLFDepPort3Localread-writecurrentLocal device card port 2 Link Loss Forwarding depends on port 3 Ethernet Rx link: 0:don't care 1:selected
1.3.6.1.4.1.4756.20.300.40.1.59Columnf1000EASXFiber2LLFDepPort4Localread-writecurrentLocal device card port 2 Link Loss Forwarding depends on port 4 Ethernet Rx link: 0:don't care 1:selected
1.3.6.1.4.1.4756.20.300.40.1.60Columnf1000EASXUtp3LLFDepLogiLocalread-writecurrentLocal device card port 3 Link Loss Forwarding depends boolean logic: 0:and 1:or
1.3.6.1.4.1.4756.20.300.40.1.61Columnf1000EASXUtp3LLFDepPort1Localread-writecurrentLocal device card port 3 Link Loss Forwarding depends on port 1 Fiber Rx link: 0:don't care 1:selected
1.3.6.1.4.1.4756.20.300.40.1.62Columnf1000EASXUtp3LLFDepPort2Localread-writecurrentLocal device card port 3 Link Loss Forwarding depends on port 2 Fiber Rx link: 0:don't care 1:selected
1.3.6.1.4.1.4756.20.300.40.1.63Columnf1000EASXUtp4LLFDepLogiLocalread-writecurrentLocal device card port 4 Link Loss Forwarding depends boolean logic: 0:and 1:or
1.3.6.1.4.1.4756.20.300.40.1.64Columnf1000EASXUtp4LLFDepPort1Localread-writecurrentLocal device card port 4 Link Loss Forwarding depends on port 1 Fiber Rx link: 0:don't care 1:selected
1.3.6.1.4.1.4756.20.300.40.1.65Columnf1000EASXUtp4LLFDepPort2Localread-writecurrentLocal device card port 4 Link Loss Forwarding depends on port 2 Fiber Rx link: 0:don't care 1:selected
1.3.6.1.4.1.4756.20.300.40.1.66Columnf1000EASXAdvanceFunsLocalread-writecurrentLocal device card Switch functions mode: 0:Normal 1:Port 1 and Port 2 Trunk Bandwidth 2G 2:Port 1 to Port 2 Mirror 4:port 1 and port 2 Redundancy 5:Static 802.…
1.3.6.1.4.1.4756.20.300.40.1.67Columnf1000EASXFiber1InfoROM1Localread-onlycurrentLocal device card port 1 INFORemoteOM information 1 valid: 0:Invalid 1:Valid
1.3.6.1.4.1.4756.20.300.40.1.68Columnf1000EASXFiber1InfoROM2Localread-onlycurrentLocal device card port 1 INFORemoteOM information 2 valid: 0:Invalid 1:Valid(replacing D/D function
1.3.6.1.4.1.4756.20.300.40.1.69Columnf1000EASXFiber2InfoROM1Localread-onlycurrentLocal device card port 2 INFORemoteOM information 1 valid: 0:Invalid 1:Valid
1.3.6.1.4.1.4756.20.300.40.1.70Columnf1000EASXFiber2InfoROM2Localread-onlycurrentLocal device card port 2 INFORemoteOM information 2 valid: 0:Invalid 1:Valid(replacing D/D function)
1.3.6.1.4.1.4756.20.300.40.1.71Columnf1000EASXFiber1InfoSN1Localread-onlycurrentLocal device card port 1 INFORemoteOM S/N 1
1.3.6.1.4.1.4756.20.300.40.1.72Columnf1000EASXFiber1InfoSN2Localread-onlycurrentLocal device card port 1 INFORemoteOM S/N 2
1.3.6.1.4.1.4756.20.300.40.1.73Columnf1000EASXFiber2InfoSN1Localread-onlycurrentLocal device card port 2 INFORemoteOM S/N 1
1.3.6.1.4.1.4756.20.300.40.1.74Columnf1000EASXFiber2InfoSN2Localread-onlycurrentLocal device card port 2 INFORemoteOM S/N 2
1.3.6.1.4.1.4756.20.300.40.1.75Columnf1000EASXFiber1DDLocalread-onlycurrentLocal device card fiber port 1 Digital Diagnostic function: 0:No 1:Yes
1.3.6.1.4.1.4756.20.300.40.1.76Columnf1000EASXFiber1DDVendorLocalread-onlycurrentLocal device card fiber port 1 D/D information: Vendor name
1.3.6.1.4.1.4756.20.300.40.1.77Columnf1000EASXFiber1DDPartNoLocalread-onlycurrentLocal device card fiber port 1 D/D information: Vendor part number
1.3.6.1.4.1.4756.20.300.40.1.78Columnf1000EASXFiber1DDVendorSNLocalread-onlycurrentLocal device card fiber port 1 D/D information: Vendor Serial Number
1.3.6.1.4.1.4756.20.300.40.1.79Columnf1000EASXFiber1DDFiberTypeLocalread-onlycurrentLocal device card fiber port 1 D/D information: Fiber Type
1.3.6.1.4.1.4756.20.300.40.1.80Columnf1000EASXFiber1DDWaveLenLocalread-onlycurrentLocal device card fiber port 1 D/D information: Wave length
1.3.6.1.4.1.4756.20.300.40.1.81Columnf1000EASXFiber1DDWaveLen2Localread-onlycurrentLocal device card fiber port 1 D/D information: Wave length 2
1.3.6.1.4.1.4756.20.300.40.1.82Columnf1000EASXFiber1DDLinkLenLocalread-onlycurrentLocal device card fiber port 1 D/D information: Link length
1.3.6.1.4.1.4756.20.300.40.1.83Columnf1000EASXFiber1DDLenUnitLocalread-onlycurrentLocal device card fiber port 1 D/D information: Length Unit
1.3.6.1.4.1.4756.20.300.40.1.84Columnf1000EASXFiber1DDStatusLocalread-onlycurrentLocal device card fiber port 1 D/D information: Status Support
1.3.6.1.4.1.4756.20.300.40.1.85Columnf1000EASXFiber1DDRxSensLocalread-onlycurrentLocal device card fiber port 1 D/D information: Rx Sensitivity
1.3.6.1.4.1.4756.20.300.40.1.86Columnf1000EASXFiber1DDTxPWRLocalread-onlycurrentLocal device card fiber port 1 D/D information: Tx power
1.3.6.1.4.1.4756.20.300.40.1.87Columnf1000EASXFiber1DDRxPWRLocalread-onlycurrentLocal device card fiber port 1 D/D information: Rx power
1.3.6.1.4.1.4756.20.300.40.1.88Columnf1000EASXFiber1DDTempLocalread-onlycurrentLocal device card fiber port 1 D/D information: Temperature in degree C
1.3.6.1.4.1.4756.20.300.40.1.89Columnf1000EASXFiber1DDPWRMarginLocalread-onlycurrentLocal device card fiber port 1 D/D information: Power margin
1.3.6.1.4.1.4756.20.300.40.1.90Columnf1000EASXFiber1DDPWRLossLocalread-onlycurrentLocal device card fiber port 1 D/D information: Power loss
1.3.6.1.4.1.4756.20.300.40.1.91Columnf1000EASXFiber2DDLocalread-onlycurrentLocal device card fiber port 2 Digital Diagnostic function: 0:No 1:Yes
1.3.6.1.4.1.4756.20.300.40.1.92Columnf1000EASXFiber2DDVendorLocalread-onlycurrentLocal device card fiber port 2 D/D information: Vendor name
1.3.6.1.4.1.4756.20.300.40.1.93Columnf1000EASXFiber2DDPartNoLocalread-onlycurrentLocal device card fiber port 2 D/D information: Vendor part number
1.3.6.1.4.1.4756.20.300.40.1.94Columnf1000EASXFiber2DDVendorSNLocalread-onlycurrentLocal device card fiber port 2 D/D information: Vendor Serial Number
1.3.6.1.4.1.4756.20.300.40.1.95Columnf1000EASXFiber2DDFiberTypeLocalread-onlycurrentLocal device card fiber port 2 D/D information: Fiber Type
1.3.6.1.4.1.4756.20.300.40.1.96Columnf1000EASXFiber2DDWaveLenLocalread-onlycurrentLocal device card fiber port 2 D/D information: Wave length
1.3.6.1.4.1.4756.20.300.40.1.97Columnf1000EASXFiber2DDWaveLen2Localread-onlycurrentLocal device card fiber port 2 D/D information: Wave length 2
1.3.6.1.4.1.4756.20.300.40.1.98Columnf1000EASXFiber2DDLinkLenLocalread-onlycurrentLocal device card fiber port 2 D/D information: Link length
1.3.6.1.4.1.4756.20.300.40.1.99Columnf1000EASXFiber2DDLenUnitLocalread-onlycurrentLocal device card fiber port 2 D/D information: Length Unit
1.3.6.1.4.1.4756.20.300.40.1.100Columnf1000EASXFiber2DDStatusLocalread-onlycurrentLocal device card fiber port 2 D/D information: Status Support
1.3.6.1.4.1.4756.20.300.40.1.101Columnf1000EASXFiber2DDRxSensLocalread-onlycurrentLocal device card fiber port 2 D/D information: Rx Sensitivity
1.3.6.1.4.1.4756.20.300.40.1.102Columnf1000EASXFiber2DDTxPWRLocalread-onlycurrentLocal device card fiber port 2 D/D information: Tx power
1.3.6.1.4.1.4756.20.300.40.1.103Columnf1000EASXFiber2DDRxPWRLocalread-onlycurrentLocal device card fiber port 2 D/D information: Rx power
1.3.6.1.4.1.4756.20.300.40.1.104Columnf1000EASXFiber2DDTempLocalread-onlycurrentLocal device card fiber port 2 D/D information: Temperature in degree C
1.3.6.1.4.1.4756.20.300.40.1.105Columnf1000EASXFiber2DDPWRMarginLocalread-onlycurrentLocal device card fiber port 2 D/D information: Power margin
1.3.6.1.4.1.4756.20.300.40.1.106Columnf1000EASXFiber2DDPWRLossLocalread-onlycurrentLocal device card fiber port 2 D/D information: Power loss
1.3.6.1.4.1.4756.20.300.40.1.107Columnf1000EASXClrRMONCntsLocalread-writecurrentClear local device card RMON IN/OUT counters: 0:No action 1:Action
1.3.6.1.4.1.4756.20.300.40.1.108Columnf1000EASXFiber1RMONInLocalread-onlycurrentLocal device card port 1 RMON IN counter.
1.3.6.1.4.1.4756.20.300.40.1.109Columnf1000EASXFiber1RMONOutLocalread-onlycurrentLocal device card port 1 RMON OUT counter.
1.3.6.1.4.1.4756.20.300.40.1.110Columnf1000EASXFiber2RMONInLocalread-onlycurrentLocal device card port 2 RMON IN counter.
1.3.6.1.4.1.4756.20.300.40.1.111Columnf1000EASXFiber2RMONOutLocalread-onlycurrentLocal device card port 2 RMON OUT counter.
1.3.6.1.4.1.4756.20.300.40.1.112Columnf1000EASXUtp3RMONInLocalread-onlycurrentLocal device card port 3 RMON IN counter.
1.3.6.1.4.1.4756.20.300.40.1.113Columnf1000EASXUtp3RMONOutLocalread-onlycurrentLocal device card port 3 RMON OUT counter.
1.3.6.1.4.1.4756.20.300.40.1.114Columnf1000EASXUtp4RMONInLocalread-onlycurrentLocal device card port 4 RMON IN counter.
1.3.6.1.4.1.4756.20.300.40.1.115Columnf1000EASXUtp4RMONOutLocalread-onlycurrentLocal device card port 4 RMON OUT counter.
1.3.6.1.4.1.4756.20.300.40.1.116Columnf1000EASXClrOAMCntsLocalread-writecurrentClear local device card OAM counters: 0:No action 1:Action
1.3.6.1.4.1.4756.20.300.40.1.117Columnf1000EASXIpModeLocalread-writecurrentOn Rack Ip Mode: 0:Enable 1:Disable
1.3.6.1.4.1.4756.20.300.40.1.118Columnf1000EASXOamChATxLocalread-onlycurrentLocal device OAM Channel A TX OAMPDU frame count
1.3.6.1.4.1.4756.20.300.40.1.119Columnf1000EASXOamChARxLocalread-onlycurrentLocal device OAM Channel A RX OAMPDU frame count
1.3.6.1.4.1.4756.20.300.40.1.120Columnf1000EASXOamInfoChATxLocalread-onlycurrentLocal device OAM Channel A TX Information OAMPDU frame count
1.3.6.1.4.1.4756.20.300.40.1.121Columnf1000EASXOamInfoChARxLocalread-onlycurrentLocal device OAM Channel A RX Information OAMPDU frame count
1.3.6.1.4.1.4756.20.300.40.1.122Columnf1000EASXOamEventChATxLocalread-onlycurrentLocal device OAM Channel A TX Event OAMPDU frame count
1.3.6.1.4.1.4756.20.300.40.1.123Columnf1000EASXOamUniEvtChARxLocalread-onlycurrentLocal device OAM Channel A RX Unique Event OAMPDU frame count
1.3.6.1.4.1.4756.20.300.40.1.124Columnf1000EASXOamDupEvtChARxLocalread-onlycurrentLocal device OAM Channel A RX Duplicate Event OAMPDU frame count
1.3.6.1.4.1.4756.20.300.40.1.125Columnf1000EASXOamLbChATxLocalread-onlycurrentLocal device OAM Channel A TX Loopback Control OAMPDU frame count
1.3.6.1.4.1.4756.20.300.40.1.126Columnf1000EASXOamLbChARxLocalread-onlycurrentLocal device OAM Channel A RX Loopback Control OAMPDU frame count
1.3.6.1.4.1.4756.20.300.40.1.127Columnf1000EASXOamVarReqChATxLocalread-onlycurrentLocal device OAM Channel A TX Variable Request OAMPDU frame count
1.3.6.1.4.1.4756.20.300.40.1.128Columnf1000EASXOamVarReqChARxLocalread-onlycurrentLocal device OAM Channel A RX Variable Request OAMPDU frame count
1.3.6.1.4.1.4756.20.300.40.1.129Columnf1000EASXOamVarRspChATxLocalread-onlycurrentLocal device OAM Channel A TX Variable Response OAMPDU frame count
1.3.6.1.4.1.4756.20.300.40.1.130Columnf1000EASXOamVarRspChARxLocalread-onlycurrentLocal device OAM Channel A RX Variable Response OAMPDU frame count
1.3.6.1.4.1.4756.20.300.40.1.131Columnf1000EASXOamOuiChATxLocalread-onlycurrentLocal device OAM Channel A TX OUI OAMPDU frame count
1.3.6.1.4.1.4756.20.300.40.1.132Columnf1000EASXOamOuiChARxLocalread-onlycurrentLocal device OAM Channel A RX OUI OAMPDU frame count
1.3.6.1.4.1.4756.20.300.40.1.133Columnf1000EASXOamUnknowChARxLocalread-onlycurrentLocal device OAM Channel A RX Unsupported OAMPDU frame count
1.3.6.1.4.1.4756.20.300.40.1.134Columnf1000EASXOamChBTxLocalread-onlycurrentLocal device OAM Channel B TX OAMPDU frame count
1.3.6.1.4.1.4756.20.300.40.1.135Columnf1000EASXOamChBRxLocalread-onlycurrentLocal device OAM Channel B RX OAMPDU frame count
1.3.6.1.4.1.4756.20.300.40.1.136Columnf1000EASXOamInfoChBTxLocalread-onlycurrentLocal device OAM Channel B TX Information OAMPDU frame count
1.3.6.1.4.1.4756.20.300.40.1.137Columnf1000EASXOamInfoChBRxLocalread-onlycurrentLocal device OAM Channel B RX Information OAMPDU frame count
1.3.6.1.4.1.4756.20.300.40.1.138Columnf1000EASXOamEventChBTxLocalread-onlycurrentLocal device OAM Channel B TX Event OAMPDU frame count
1.3.6.1.4.1.4756.20.300.40.1.139Columnf1000EASXOamUniEvtChBRxLocalread-onlycurrentLocal device OAM Channel B RX Unique Event OAMPDU frame count
1.3.6.1.4.1.4756.20.300.40.1.140Columnf1000EASXOamDupEvtChBRxLocalread-onlycurrentLocal device OAM Channel B RX Duplicate Event OAMPDU frame count
1.3.6.1.4.1.4756.20.300.40.1.141Columnf1000EASXOamLbChBTxLocalread-onlycurrentLocal device OAM Channel B TX Loopback Control OAMPDU frame count
1.3.6.1.4.1.4756.20.300.40.1.142Columnf1000EASXOamLbChBRxLocalread-onlycurrentLocal device OAM Channel B RX Loopback Control OAMPDU frame count
1.3.6.1.4.1.4756.20.300.40.1.143Columnf1000EASXOamVarReqChBTxLocalread-onlycurrentLocal device OAM Channel B TX Variable Request OAMPDU frame count
1.3.6.1.4.1.4756.20.300.40.1.144Columnf1000EASXOamVarReqChBRxLocalread-onlycurrentLocal device OAM Channel B RX Variable Request OAMPDU frame count
1.3.6.1.4.1.4756.20.300.40.1.145Columnf1000EASXOamVarRspChBTxLocalread-onlycurrentLocal device OAM Channel B TX Variable Response OAMPDU frame count
1.3.6.1.4.1.4756.20.300.40.1.146Columnf1000EASXOamVarRspChBRxLocalread-onlycurrentLocal device OAM Channel B RX Variable Response OAMPDU frame count
1.3.6.1.4.1.4756.20.300.40.1.147Columnf1000EASXOamOuiChBTxLocalread-onlycurrentLocal device OAM Channel B TX OUI OAMPDU frame count
1.3.6.1.4.1.4756.20.300.40.1.148Columnf1000EASXOamOuiChBRxLocalread-onlycurrentLocal device OAM Channel B RX OUI OAMPDU frame count
1.3.6.1.4.1.4756.20.300.40.1.149Columnf1000EASXOamUnknowChBRxLocalread-onlycurrentLocal device OAM Channel B RX Unsupported OAMPDU frame count
1.3.6.1.4.1.4756.20.300.40.1.150Columnf1000EASXFiber1SpeedLocalread-writecurrentLocal device Fiber 1 speed : 0:1000Auto 1:1000FDX 2:100FDX
1.3.6.1.4.1.4756.20.300.40.1.151Columnf1000EASXFiber2SpeedLocalread-writecurrentLocal device Fiber 2 speed : 0:1000Auto 1:1000FDX 2:100FDX
1.3.6.1.4.1.4756.20.300.40.1.152Columnf1000EASXMacLearningLocalread-writecurrentLocal device Mac learning : 0:Disable 1:Enable
1.3.6.1.4.1.4756.20.300.40.1.153Columnf1000EASXFiber1VLANLocalread-writecurrentLocal device Fiber 1 VLAN group : 0:Group A 1:Group B
1.3.6.1.4.1.4756.20.300.40.1.154Columnf1000EASXFiber2VLANLocalread-writecurrentLocal device Fiber 2 VLAN group : 0:Group A 1:Group B
1.3.6.1.4.1.4756.20.300.40.1.155Columnf1000EASXUtp3VLANLocalread-writecurrentLocal device UTP 3 VLAN group : 0:Group A 1:Group B
1.3.6.1.4.1.4756.20.300.40.1.156Columnf1000EASXUtp4VLANLocalread-writecurrentLocal device UTP 4 VLAN group : 0:Group A 1:Group B
1.3.6.1.4.1.4756.20.300.40.1.157Columnf1000EASXManagementLocalread-writecurrentLocal device management : 0:Group A 1:Group B 2:Group A+B
1.3.6.1.4.1.4756.20.300.40.1.158Columnf1000EASXRedundancyModeLocalread-writecurrentLocal device redundancy mode : 0:Auto 1:Manual Fiber 1 2:Manual Fiber 2 3:No Reverse 4:Link Budget
1.3.6.1.4.1.4756.20.300.40.1.159Columnf1000EASXPortVLANLocalread-writecurrentLocal device redundancy mode : 0:Disalbe 1:Enable
1.3.6.1.4.1.4756.20.300.40.1.160Columnf1000EASXRemoteTLPTLocalread-writecurrentLocal device redundancy mode : 0:Disalbe 1:Remote A 2:Remote B 3:Remote A&B 4:Remote A/3; Remote B/4
1.3.6.1.4.1.4756.20.300.40.1.161Columnf1000EASXManagementVIDLocalread-writecurrentLocal device Management VID :
1.3.6.1.4.1.4756.20.300.40.1.162Columnf1000EASXThresholdLocalread-writecurrentLocal device Threshold:
1.3.6.1.4.1.4756.20.300.40.1.163Columnf1000EASXSensitivityLocalread-writecurrentLocal device Sensitivity:
1.3.6.1.4.1.4756.20.300.40.1.164Columnf1000EASXTagTypeLocalread-writecurrentLocal device Tag Type (HEX) :
1.3.6.1.4.1.4756.20.300.40.1.165Columnf1000EASXPort1VIDLocalread-writecurrentLocal device Port 1 VID :
1.3.6.1.4.1.4756.20.300.40.1.166Columnf1000EASXPort2VIDLocalread-writecurrentLocal device Port 2 VID :
1.3.6.1.4.1.4756.20.300.40.1.167Columnf1000EASXPort3VIDLocalread-writecurrentLocal device Port 3 VID :
1.3.6.1.4.1.4756.20.300.40.1.168Columnf1000EASXPort4VIDLocalread-writecurrentLocal device Port 4 VID :
1.3.6.1.4.1.4756.20.300.40.1.169Columnf1000EASXPort1QinQLocalread-writecurrentLocal device Port 1 Q in Q Support : 1:Disable 2:Enable
1.3.6.1.4.1.4756.20.300.40.1.170Columnf1000EASXPort2QinQLocalread-writecurrentLocal device Port 2 Q in Q Support : 1:Disable 2:Enable
1.3.6.1.4.1.4756.20.300.40.1.171Columnf1000EASXPort3QinQLocalread-writecurrentLocal device Port 3 Q in Q Support : 1:Disable 2:Enable
1.3.6.1.4.1.4756.20.300.40.1.172Columnf1000EASXPort4QinQLocalread-writecurrentLocal device Port 4 Q in Q Support : 1:Disable 2:Enable
1.3.6.1.4.1.4756.20.300.40.1.173Columnf1000EASXVID1Localread-writecurrentLocal device VID 1:
1.3.6.1.4.1.4756.20.300.40.1.174Columnf1000EASXVID2Localread-writecurrentLocal device VID 2:
1.3.6.1.4.1.4756.20.300.40.1.175Columnf1000EASXVID3Localread-writecurrentLocal device VID 3:
1.3.6.1.4.1.4756.20.300.40.1.176Columnf1000EASXVID4Localread-writecurrentLocal device VID 4:
1.3.6.1.4.1.4756.20.300.40.1.177Columnf1000EASXVID5Localread-writecurrentLocal device VID 5:
1.3.6.1.4.1.4756.20.300.40.1.178Columnf1000EASXVID6Localread-writecurrentLocal device VID 6:
1.3.6.1.4.1.4756.20.300.40.1.179Columnf1000EASXVID7Localread-writecurrentLocal device VID 7:
1.3.6.1.4.1.4756.20.300.40.1.180Columnf1000EASXVID8Localread-writecurrentLocal device VID 8:
1.3.6.1.4.1.4756.20.300.40.1.181Columnf1000EASXVID9Localread-writecurrentLocal device VID 9:
1.3.6.1.4.1.4756.20.300.40.1.182Columnf1000EASXVID10Localread-writecurrentLocal device VID 10:
1.3.6.1.4.1.4756.20.300.40.1.183Columnf1000EASXVID11Localread-writecurrentLocal device VID 11:
1.3.6.1.4.1.4756.20.300.40.1.184Columnf1000EASXVID12Localread-writecurrentLocal device VID 12:
1.3.6.1.4.1.4756.20.300.40.1.185Columnf1000EASXVID13Localread-writecurrentLocal device VID 13:
1.3.6.1.4.1.4756.20.300.40.1.186Columnf1000EASXVID14Localread-writecurrentLocal device VID 14:
1.3.6.1.4.1.4756.20.300.40.1.187Columnf1000EASXVID15Localread-writecurrentLocal device VID 15:
1.3.6.1.4.1.4756.20.300.40.1.188Columnf1000EASXVID16Localread-writecurrentLocal device VID 16:
1.3.6.1.4.1.4756.20.300.40.1.189Columnf1000EASXPort1Member1Localread-writecurrentLocal device card port 1 member: 0:Unmodify 1:Untagged 2:Tagged 3:Nonmember
1.3.6.1.4.1.4756.20.300.40.1.190Columnf1000EASXPort1Member2Localread-writecurrentLocal device card port 1 member 2: 0:Unmodify 1:Untagged 2:Tagged 3:Nonmember
1.3.6.1.4.1.4756.20.300.40.1.191Columnf1000EASXPort1Member3Localread-writecurrentLocal device card port 1 member 3: 0:Unmodify 1:Untagged 2:Tagged 3:Nonmember
1.3.6.1.4.1.4756.20.300.40.1.192Columnf1000EASXPort1Member4Localread-writecurrentLocal device card port 1 member 4: 0:Unmodify 1:Untagged 2:Tagged 3:Nonmember
1.3.6.1.4.1.4756.20.300.40.1.193Columnf1000EASXPort1Member5Localread-writecurrentLocal device card port 1 member 5: 0:Unmodify 1:Untagged 2:Tagged 3:Nonmember
1.3.6.1.4.1.4756.20.300.40.1.194Columnf1000EASXPort1Member6Localread-writecurrentLocal device card port 1 member 6: 0:Unmodify 1:Untagged 2:Tagged 3:Nonmember
1.3.6.1.4.1.4756.20.300.40.1.195Columnf1000EASXPort1Member7Localread-writecurrentLocal device card port 1 member 7: 0:Unmodify 1:Untagged 2:Tagged 3:Nonmember
1.3.6.1.4.1.4756.20.300.40.1.196Columnf1000EASXPort1Member8Localread-writecurrentLocal device card port 1 member 8: 0:Unmodify 1:Untagged 2:Tagged 3:Nonmember
1.3.6.1.4.1.4756.20.300.40.1.197Columnf1000EASXPort1Member9Localread-writecurrentLocal device card port 1 member 9: 0:Unmodify 1:Untagged 2:Tagged 3:Nonmember
1.3.6.1.4.1.4756.20.300.40.1.198Columnf1000EASXPort1Member10Localread-writecurrentLocal device card port 1 member 10: 0:Unmodify 1:Untagged 2:Tagged 3:Nonmember
1.3.6.1.4.1.4756.20.300.40.1.199Columnf1000EASXPort1Member11Localread-writecurrentLocal device card port 1 member 11: 0:Unmodify 1:Untagged 2:Tagged 3:Nonmember
1.3.6.1.4.1.4756.20.300.40.1.200Columnf1000EASXPort1Member12Localread-writecurrentLocal device card port 1 member 12: 0:Unmodify 1:Untagged 2:Tagged 3:Nonmember
1.3.6.1.4.1.4756.20.300.40.1.201Columnf1000EASXPort1Member13Localread-writecurrentLocal device card port 1 member 13: 0:Unmodify 1:Untagged 2:Tagged 3:Nonmember
1.3.6.1.4.1.4756.20.300.40.1.202Columnf1000EASXPort1Member14Localread-writecurrentLocal device card port 1 member 14: 0:Unmodify 1:Untagged 2:Tagged 3:Nonmember
1.3.6.1.4.1.4756.20.300.40.1.203Columnf1000EASXPort1Member15Localread-writecurrentLocal device card port 1 member 15: 0:Unmodify 1:Untagged 2:Tagged 3:Nonmember
1.3.6.1.4.1.4756.20.300.40.1.204Columnf1000EASXPort1Member16Localread-writecurrentLocal device card port 1 member 16: 0:Unmodify 1:Untagged 2:Tagged 3:Nonmember
1.3.6.1.4.1.4756.20.300.40.1.205Columnf1000EASXPort2Member1Localread-writecurrentLocal device card port 2 member: 0:Unmodify 1:Untagged 2:Tagged 3:Nonmember
1.3.6.1.4.1.4756.20.300.40.1.206Columnf1000EASXPort2Member2Localread-writecurrentLocal device card port 2 member 2: 0:Unmodify 1:Untagged 2:Tagged 3:Nonmember
1.3.6.1.4.1.4756.20.300.40.1.207Columnf1000EASXPort2Member3Localread-writecurrentLocal device card port 2 member 3: 0:Unmodify 1:Untagged 2:Tagged 3:Nonmember
1.3.6.1.4.1.4756.20.300.40.1.208Columnf1000EASXPort2Member4Localread-writecurrentLocal device card port 2 member 4: 0:Unmodify 1:Untagged 2:Tagged 3:Nonmember
1.3.6.1.4.1.4756.20.300.40.1.209Columnf1000EASXPort2Member5Localread-writecurrentLocal device card port 2 member 5: 0:Unmodify 1:Untagged 2:Tagged 3:Nonmember
1.3.6.1.4.1.4756.20.300.40.1.210Columnf1000EASXPort2Member6Localread-writecurrentLocal device card port 2 member 6: 0:Unmodify 1:Untagged 2:Tagged 3:Nonmember
1.3.6.1.4.1.4756.20.300.40.1.211Columnf1000EASXPort2Member7Localread-writecurrentLocal device card port 2 member 7: 0:Unmodify 1:Untagged 2:Tagged 3:Nonmember
1.3.6.1.4.1.4756.20.300.40.1.212Columnf1000EASXPort2Member8Localread-writecurrentLocal device card port 2 member 8: 0:Unmodify 1:Untagged 2:Tagged 3:Nonmember
1.3.6.1.4.1.4756.20.300.40.1.213Columnf1000EASXPort2Member9Localread-writecurrentLocal device card port 2 member 9: 0:Unmodify 1:Untagged 2:Tagged 3:Nonmember
1.3.6.1.4.1.4756.20.300.40.1.214Columnf1000EASXPort2Member10Localread-writecurrentLocal device card port 2 member 10: 0:Unmodify 1:Untagged 2:Tagged 3:Nonmember
1.3.6.1.4.1.4756.20.300.40.1.215Columnf1000EASXPort2Member11Localread-writecurrentLocal device card port 2 member 11: 0:Unmodify 1:Untagged 2:Tagged 3:Nonmember
1.3.6.1.4.1.4756.20.300.40.1.216Columnf1000EASXPort2Member12Localread-writecurrentLocal device card port 2 member 12: 0:Unmodify 1:Untagged 2:Tagged 3:Nonmember
1.3.6.1.4.1.4756.20.300.40.1.217Columnf1000EASXPort2Member13Localread-writecurrentLocal device card port 2 member 13: 0:Unmodify 1:Untagged 2:Tagged 3:Nonmember
1.3.6.1.4.1.4756.20.300.40.1.218Columnf1000EASXPort2Member14Localread-writecurrentLocal device card port 2 member 14: 0:Unmodify 1:Untagged 2:Tagged 3:Nonmember
1.3.6.1.4.1.4756.20.300.40.1.219Columnf1000EASXPort2Member15Localread-writecurrentLocal device card port 2 member 15: 0:Unmodify 1:Untagged 2:Tagged 3:Nonmember
1.3.6.1.4.1.4756.20.300.40.1.220Columnf1000EASXPort2Member16Localread-writecurrentLocal device card port 2 member 16: 0:Unmodify 1:Untagged 2:Tagged 3:Nonmember
1.3.6.1.4.1.4756.20.300.40.1.221Columnf1000EASXPort3Member1Localread-writecurrentLocal device card port 3 member: 0:Unmodify 1:Untagged 2:Tagged 3:Nonmember
1.3.6.1.4.1.4756.20.300.40.1.222Columnf1000EASXPort3Member2Localread-writecurrentLocal device card port 3 member 2: 0:Unmodify 1:Untagged 2:Tagged 3:Nonmember
1.3.6.1.4.1.4756.20.300.40.1.223Columnf1000EASXPort3Member3Localread-writecurrentLocal device card port 3 member 3: 0:Unmodify 1:Untagged 2:Tagged 3:Nonmember
1.3.6.1.4.1.4756.20.300.40.1.224Columnf1000EASXPort3Member4Localread-writecurrentLocal device card port 3 member 4: 0:Unmodify 1:Untagged 2:Tagged 3:Nonmember
1.3.6.1.4.1.4756.20.300.40.1.225Columnf1000EASXPort3Member5Localread-writecurrentLocal device card port 3 member 5: 0:Unmodify 1:Untagged 2:Tagged 3:Nonmember
1.3.6.1.4.1.4756.20.300.40.1.226Columnf1000EASXPort3Member6Localread-writecurrentLocal device card port 3 member 6: 0:Unmodify 1:Untagged 2:Tagged 3:Nonmember
1.3.6.1.4.1.4756.20.300.40.1.227Columnf1000EASXPort3Member7Localread-writecurrentLocal device card port 3 member 7: 0:Unmodify 1:Untagged 2:Tagged 3:Nonmember
1.3.6.1.4.1.4756.20.300.40.1.228Columnf1000EASXPort3Member8Localread-writecurrentLocal device card port 3 member 8: 0:Unmodify 1:Untagged 2:Tagged 3:Nonmember
1.3.6.1.4.1.4756.20.300.40.1.229Columnf1000EASXPort3Member9Localread-writecurrentLocal device card port 3 member 9: 0:Unmodify 1:Untagged 2:Tagged 3:Nonmember
1.3.6.1.4.1.4756.20.300.40.1.230Columnf1000EASXPort3Member10Localread-writecurrentLocal device card port 3 member 10: 0:Unmodify 1:Untagged 2:Tagged 3:Nonmember
1.3.6.1.4.1.4756.20.300.40.1.231Columnf1000EASXPort3Member11Localread-writecurrentLocal device card port 3 member 11: 0:Unmodify 1:Untagged 2:Tagged 3:Nonmember
1.3.6.1.4.1.4756.20.300.40.1.232Columnf1000EASXPort3Member12Localread-writecurrentLocal device card port 3 member 12: 0:Unmodify 1:Untagged 2:Tagged 3:Nonmember
1.3.6.1.4.1.4756.20.300.40.1.233Columnf1000EASXPort3Member13Localread-writecurrentLocal device card port 3 member 13: 0:Unmodify 1:Untagged 2:Tagged 3:Nonmember
1.3.6.1.4.1.4756.20.300.40.1.234Columnf1000EASXPort3Member14Localread-writecurrentLocal device card port 3 member 14: 0:Unmodify 1:Untagged 2:Tagged 3:Nonmember
1.3.6.1.4.1.4756.20.300.40.1.235Columnf1000EASXPort3Member15Localread-writecurrentLocal device card port 3 member 15: 0:Unmodify 1:Untagged 2:Tagged 3:Nonmember
1.3.6.1.4.1.4756.20.300.40.1.236Columnf1000EASXPort3Member16Localread-writecurrentLocal device card port 3 member 16: 0:Unmodify 1:Untagged 2:Tagged 3:Nonmember
1.3.6.1.4.1.4756.20.300.40.1.237Columnf1000EASXPort4Member1Localread-writecurrentLocal device card port 4 member: 0:Unmodify 1:Untagged 2:Tagged 3:Nonmember
1.3.6.1.4.1.4756.20.300.40.1.238Columnf1000EASXPort4Member2Localread-writecurrentLocal device card port 4 member 2: 0:Unmodify 1:Untagged 2:Tagged 3:Nonmember
1.3.6.1.4.1.4756.20.300.40.1.239Columnf1000EASXPort4Member3Localread-writecurrentLocal device card port 4 member 3: 0:Unmodify 1:Untagged 2:Tagged 3:Nonmember
1.3.6.1.4.1.4756.20.300.40.1.240Columnf1000EASXPort4Member4Localread-writecurrentLocal device card port 4 member 4: 0:Unmodify 1:Untagged 2:Tagged 3:Nonmember
1.3.6.1.4.1.4756.20.300.40.1.241Columnf1000EASXPort4Member5Localread-writecurrentLocal device card port 4 member 5: 0:Unmodify 1:Untagged 2:Tagged 3:Nonmember
1.3.6.1.4.1.4756.20.300.40.1.242Columnf1000EASXPort4Member6Localread-writecurrentLocal device card port 4 member 6: 0:Unmodify 1:Untagged 2:Tagged 3:Nonmember
1.3.6.1.4.1.4756.20.300.40.1.243Columnf1000EASXPort4Member7Localread-writecurrentLocal device card port 4 member 7: 0:Unmodify 1:Untagged 2:Tagged 3:Nonmember
1.3.6.1.4.1.4756.20.300.40.1.244Columnf1000EASXPort4Member8Localread-writecurrentLocal device card port 4 member 8: 0:Unmodify 1:Untagged 2:Tagged 3:Nonmember
1.3.6.1.4.1.4756.20.300.40.1.245Columnf1000EASXPort4Member9Localread-writecurrentLocal device card port 4 member 9: 0:Unmodify 1:Untagged 2:Tagged 3:Nonmember
1.3.6.1.4.1.4756.20.300.40.1.246Columnf1000EASXPort4Member10Localread-writecurrentLocal device card port 4 member 10: 0:Unmodify 1:Untagged 2:Tagged 3:Nonmember
1.3.6.1.4.1.4756.20.300.40.1.247Columnf1000EASXPort4Member11Localread-writecurrentLocal device card port 4 member 11: 0:Unmodify 1:Untagged 2:Tagged 3:Nonmember
1.3.6.1.4.1.4756.20.300.40.1.248Columnf1000EASXPort4Member12Localread-writecurrentLocal device card port 4 member 12: 0:Unmodify 1:Untagged 2:Tagged 3:Nonmember
1.3.6.1.4.1.4756.20.300.40.1.249Columnf1000EASXPort4Member13Localread-writecurrentLocal device card port 4 member 13: 0:Unmodify 1:Untagged 2:Tagged 3:Nonmember
1.3.6.1.4.1.4756.20.300.40.1.250Columnf1000EASXPort4Member14Localread-writecurrentLocal device card port 4 member 14: 0:Unmodify 1:Untagged 2:Tagged 3:Nonmember
1.3.6.1.4.1.4756.20.300.40.1.251Columnf1000EASXPort4Member15Localread-writecurrentLocal device card port 4 member 15: 0:Unmodify 1:Untagged 2:Tagged 3:Nonmember
1.3.6.1.4.1.4756.20.300.40.1.252Columnf1000EASXPort4Member16Localread-writecurrentLocal device card port 4 member 16: 0:Unmodify 1:Untagged 2:Tagged 3:Nonmember
1.3.6.1.4.1.4756.20.300.40.1.253Columnf1000EASXIpAddressLocalread-writecurrentLocal device IP address
1.3.6.1.4.1.4756.20.300.40.1.254Columnf1000EASXNetMaskLocalread-writecurrentLocal device Netmask
1.3.6.1.4.1.4756.20.300.40.1.255Columnf1000EASXGateWayLocalread-writecurrentLocal device Gateway
1.3.6.1.4.1.4756.20.300.40.1.256Columnf1000EASXSetDefaultLocalread-writecurrentLocal device set to default
1.3.6.1.4.1.4756.20.300.40.1.257Columnf1000EASXFx1LinkAlarmLocalread-writecurrentLocal device fiber 1 link alarm 0:Disable 1:Enable
1.3.6.1.4.1.4756.20.300.40.1.258Columnf1000EASXFx2LinkAlarmLocalread-writecurrentLocal device fiber 2 link alarm 0:Disable 1:Enable
1.3.6.1.4.1.4756.20.300.40.1.259Columnf1000EASXUtp3LinkAlarmLocalread-writecurrentLocal device utp 3 link alarm 0:Disable 1:Enable
1.3.6.1.4.1.4756.20.300.40.1.260Columnf1000EASXUtp4LinkAlarmLocalread-writecurrentLocal device utp 4 link alarm 0:Disable 1:Enable
1.3.6.1.4.1.4756.20.300.40.1.261Columnf1000EASXFiber1FEFLocalread-onlycurrentLocal device card fiber1 port FEF status: 0:Off 1:Detected
1.3.6.1.4.1.4756.20.300.40.1.262Columnf1000EASXFiber2FEFLocalread-onlycurrentLocal device card fiber2 port FEF status: 0:Off 1:Detected
1.3.6.1.4.1.4756.20.300.40.1.263Columnf1000EASXPingStatusLocalread-onlycurrentLocal device icmp ping status Show Ping Status 0: Normal 1: Not Ready 2: 5 packets transmitted, 5 received, 0 packet loss. (Ping OK) 3: 5 packets transmitted, …
1.3.6.1.4.1.4756.20.300.40.1.264Columnf1000EASXPingIpAddressLocalread-writecurrentLocal device ping IP address
1.3.6.1.4.1.4756.20.300.40.1.265Columnf1000EASXPingStartLocalread-writecurrentLocal device ping start 0:Off 1:Action
1.3.6.1.4.1.4756.20.300.40.1.266Columnf1000EASXFX1RXOctetsLocalread-onlycurrentFRM220-1000EAS/X RMON Fiber 1 Receiver Octets.
1.3.6.1.4.1.4756.20.300.40.1.267Columnf1000EASXFX1RXPacketLocalread-onlycurrentFRM220-1000EAS/X RMON Fiber 1 Receiver Packets.
1.3.6.1.4.1.4756.20.300.40.1.268Columnf1000EASXFX1RXBroadLocalread-onlycurrentFRM220-1000EAS/X RMON Fiber 1 Receiver Broadcast Packets.
1.3.6.1.4.1.4756.20.300.40.1.269Columnf1000EASXFX1RXMultiLocalread-onlycurrentFRM220-1000EAS/X RMON Fiber 1 Receiver Multicast Packets.
1.3.6.1.4.1.4756.20.300.40.1.270Columnf1000EASXFX1RXUniLocalread-onlycurrentFRM220-1000EAS/X RMON Fiber 1 Receiver Unicast Packets.
1.3.6.1.4.1.4756.20.300.40.1.271Columnf1000EASXFX1RXPauseLocalread-onlycurrentFRM220-1000EAS/X RMON Fiber 1 Receiver Pause Packets.
1.3.6.1.4.1.4756.20.300.40.1.272Columnf1000EASXFX1RXFCSELocalread-onlycurrentFRM220-1000EAS/X RMON Fiber 1 Receiver FCS Error Packets.
1.3.6.1.4.1.4756.20.300.40.1.273Columnf1000EASXFX1RXUnderLocalread-onlycurrentFRM220-1000EAS/X RMON Fiber 1 Receiver Under Packets.
1.3.6.1.4.1.4756.20.300.40.1.274Columnf1000EASXFX1RXOverLocalread-onlycurrentFRM220-1000EAS/X RMON Fiber 1 Receiver Over Packets.
1.3.6.1.4.1.4756.20.300.40.1.275Columnf1000EASXFX1RXJabberLocalread-onlycurrentFRM220-1000EAS/X RMON Fiber 1 Receiver Jabber Packets.
1.3.6.1.4.1.4756.20.300.40.1.276Columnf1000EASXFX1TXOctetsLocalread-onlycurrentFRM220-1000EAS/X RMON Fiber 1 Transceiver Octets.
1.3.6.1.4.1.4756.20.300.40.1.277Columnf1000EASXFX1TXPacketLocalread-onlycurrentFRM220-1000EAS/X RMON Fiber 1 Transceiver Packets.
1.3.6.1.4.1.4756.20.300.40.1.278Columnf1000EASXFX1TXBroadLocalread-onlycurrentFRM220-1000EAS/X RMON Fiber 1 Transceiver Broadcast Packets.
1.3.6.1.4.1.4756.20.300.40.1.279Columnf1000EASXFX1TXMultiLocalread-onlycurrentFRM220-1000EAS/X RMON Fiber 1 Transceiver Multicast Packets.
1.3.6.1.4.1.4756.20.300.40.1.280Columnf1000EASXFX1TXUniLocalread-onlycurrentFRM220-1000EAS/X RMON Fiber 1 Transceiver Unicast Packets.
1.3.6.1.4.1.4756.20.300.40.1.281Columnf1000EASXFX1TXPauseLocalread-onlycurrentFRM220-1000EAS/X RMON Fiber 1 Transceiver Pause Packets.
1.3.6.1.4.1.4756.20.300.40.1.282Columnf1000EASXFX1TXCollisionLocalread-onlycurrentFRM220-1000EAS/X RMON Fiber 1 Transceiver Collision Packets.
1.3.6.1.4.1.4756.20.300.40.1.283Columnf1000EASXFX10OctetsLocalread-onlycurrentFRM220-1000EAS/X RMON Fiber 1 Transceiver/Receiver 0~64 Octets.
1.3.6.1.4.1.4756.20.300.40.1.284Columnf1000EASXFX165OctetsLocalread-onlycurrentFRM220-1000EAS/X RMON Fiber 1 Transceiver/Receiver 65~127 Octets.
1.3.6.1.4.1.4756.20.300.40.1.285Columnf1000EASXFX1128OctetsLocalread-onlycurrentFRM220-1000EAS/X RMON Fiber 1 Transceiver/Receiver 128~255 Octets.
1.3.6.1.4.1.4756.20.300.40.1.286Columnf1000EASXFX1256OctetsLocalread-onlycurrentFRM220-1000EAS/X RMON Fiber 1 Transceiver/Receiver 256~511 Octets.
1.3.6.1.4.1.4756.20.300.40.1.287Columnf1000EASXFX1512OctetsLocalread-onlycurrentFRM220-1000EAS/X RMON Fiber 1 Transceiver/Receiver 512~1023 Octets.
1.3.6.1.4.1.4756.20.300.40.1.288Columnf1000EASXFX11024OctetsLocalread-onlycurrentFRM220-1000EAS/X RMON Fiber 1 Transceiver/Receiver 1024~Max Octets.
1.3.6.1.4.1.4756.20.300.40.1.289Columnf1000EASXFX2RXOctetsLocalread-onlycurrentFRM220-1000EAS/X RMON Fiber 2 Receiver Octets.
1.3.6.1.4.1.4756.20.300.40.1.290Columnf1000EASXFX2RXPacketLocalread-onlycurrentFRM220-1000EAS/X RMON Fiber 2 Receiver Packets.
1.3.6.1.4.1.4756.20.300.40.1.291Columnf1000EASXFX2RXBroadLocalread-onlycurrentFRM220-1000EAS/X RMON Fiber 2 Receiver Broadcast Packets.
1.3.6.1.4.1.4756.20.300.40.1.292Columnf1000EASXFX2RXMultiLocalread-onlycurrentFRM220-1000EAS/X RMON Fiber 2 Receiver Multicast Packets.
1.3.6.1.4.1.4756.20.300.40.1.293Columnf1000EASXFX2RXUniLocalread-onlycurrentFRM220-1000EAS/X RMON Fiber 2 Receiver Unicast Packets.
1.3.6.1.4.1.4756.20.300.40.1.294Columnf1000EASXFX2RXPauseLocalread-onlycurrentFRM220-1000EAS/X RMON Fiber 2 Receiver Pause Packets.
1.3.6.1.4.1.4756.20.300.40.1.295Columnf1000EASXFX2RXFCSELocalread-onlycurrentFRM220-1000EAS/X RMON Fiber 2 Receiver FCS Error Packets.
1.3.6.1.4.1.4756.20.300.40.1.296Columnf1000EASXFX2RXUnderLocalread-onlycurrentFRM220-1000EAS/X RMON Fiber 2 Receiver Under Packets.
1.3.6.1.4.1.4756.20.300.40.1.297Columnf1000EASXFX2RXOverLocalread-onlycurrentFRM220-1000EAS/X RMON Fiber 2 Receiver Over Packets.
1.3.6.1.4.1.4756.20.300.40.1.298Columnf1000EASXFX2RXJabberLocalread-onlycurrentFRM220-1000EAS/X RMON Fiber 2 Receiver Jabber Packets.
1.3.6.1.4.1.4756.20.300.40.1.299Columnf1000EASXFX2TXOctetsLocalread-onlycurrentFRM220-1000EAS/X RMON Fiber 2 Transceiver Octets.
1.3.6.1.4.1.4756.20.300.40.1.300Columnf1000EASXFX2TXPacketLocalread-onlycurrentFRM220-1000EAS/X RMON Fiber 2 Transceiver Packets.
1.3.6.1.4.1.4756.20.300.40.1.301Columnf1000EASXFX2TXBroadLocalread-onlycurrentFRM220-1000EAS/X RMON Fiber 2 Transceiver Broadcast Packets.
1.3.6.1.4.1.4756.20.300.40.1.302Columnf1000EASXFX2TXMultiLocalread-onlycurrentFRM220-1000EAS/X RMON Fiber 2 Transceiver Multicast Packets.
1.3.6.1.4.1.4756.20.300.40.1.303Columnf1000EASXFX2TXUniLocalread-onlycurrentFRM220-1000EAS/X RMON Fiber 2 Transceiver Unicast Packets.
1.3.6.1.4.1.4756.20.300.40.1.304Columnf1000EASXFX2TXPauseLocalread-onlycurrentFRM220-1000EAS/X RMON Fiber 2 Transceiver Pause Packets.
1.3.6.1.4.1.4756.20.300.40.1.305Columnf1000EASXFX2TXCollisionLocalread-onlycurrentFRM220-1000EAS/X RMON Fiber 2 Transceiver Collision Packets.
1.3.6.1.4.1.4756.20.300.40.1.306Columnf1000EASXFX20OctetsLocalread-onlycurrentFRM220-1000EAS/X RMON Fiber 2 Transceiver/Receiver 0~64 Octets.
1.3.6.1.4.1.4756.20.300.40.1.307Columnf1000EASXFX265OctetsLocalread-onlycurrentFRM220-1000EAS/X RMON Fiber 2 Transceiver/Receiver 65~127 Octets.
1.3.6.1.4.1.4756.20.300.40.1.308Columnf1000EASXFX2128OctetsLocalread-onlycurrentFRM220-1000EAS/X RMON Fiber 2 Transceiver/Receiver 128~255 Octets.
1.3.6.1.4.1.4756.20.300.40.1.309Columnf1000EASXFX2256OctetsLocalread-onlycurrentFRM220-1000EAS/X RMON Fiber 2 Transceiver/Receiver 256~511 Octets.
1.3.6.1.4.1.4756.20.300.40.1.310Columnf1000EASXFX2512OctetsLocalread-onlycurrentFRM220-1000EAS/X RMON Fiber 2 Transceiver/Receiver 512~1023 Octets.
1.3.6.1.4.1.4756.20.300.40.1.311Columnf1000EASXFX21024OctetsLocalread-onlycurrentFRM220-1000EAS/X RMON Fiber 2 Transceiver/Receiver 1024~Max Octets.
1.3.6.1.4.1.4756.20.300.40.1.312Columnf1000EASXUTP3RXOctetsLocalread-onlycurrentFRM220-1000EAS/X RMON UTP 3 Receiver Octets.
1.3.6.1.4.1.4756.20.300.40.1.313Columnf1000EASXUTP3RXPacketLocalread-onlycurrentFRM220-1000EAS/X RMON UTP 3 Receiver Packets.
1.3.6.1.4.1.4756.20.300.40.1.314Columnf1000EASXUTP3RXBroadLocalread-onlycurrentFRM220-1000EAS/X RMON UTP 3 Receiver Broadcast Packets.
1.3.6.1.4.1.4756.20.300.40.1.315Columnf1000EASXUTP3RXMultiLocalread-onlycurrentFRM220-1000EAS/X RMON UTP 3 Receiver Multicast Packets.
1.3.6.1.4.1.4756.20.300.40.1.316Columnf1000EASXUTP3RXUniLocalread-onlycurrentFRM220-1000EAS/X RMON UTP 3 Receiver Unicast Packets.
1.3.6.1.4.1.4756.20.300.40.1.317Columnf1000EASXUTP3RXPauseLocalread-onlycurrentFRM220-1000EAS/X RMON UTP 3 Receiver Pause Packets.
1.3.6.1.4.1.4756.20.300.40.1.318Columnf1000EASXUTP3RXFCSELocalread-onlycurrentFRM220-1000EAS/X RMON UTP 3 Receiver FCS Error Packets.
1.3.6.1.4.1.4756.20.300.40.1.319Columnf1000EASXUTP3RXUnderLocalread-onlycurrentFRM220-1000EAS/X RMON UTP 3 Receiver Under Packets.
1.3.6.1.4.1.4756.20.300.40.1.320Columnf1000EASXUTP3RXOverLocalread-onlycurrentFRM220-1000EAS/X RMON UTP 3 Receiver Over Packets.
1.3.6.1.4.1.4756.20.300.40.1.321Columnf1000EASXUTP3RXJabberLocalread-onlycurrentFRM220-1000EAS/X RMON UTP 3 Receiver Jabber Packets.
1.3.6.1.4.1.4756.20.300.40.1.322Columnf1000EASXUTP3TXOctetsLocalread-onlycurrentFRM220-1000EAS/X RMON UTP 3 Transceiver Octets.
1.3.6.1.4.1.4756.20.300.40.1.323Columnf1000EASXUTP3TXPacketLocalread-onlycurrentFRM220-1000EAS/X RMON UTP 3 Transceiver Packets.
1.3.6.1.4.1.4756.20.300.40.1.324Columnf1000EASXUTP3TXBroadLocalread-onlycurrentFRM220-1000EAS/X RMON UTP 3 Transceiver Broadcast Packets.
1.3.6.1.4.1.4756.20.300.40.1.325Columnf1000EASXUTP3TXMultiLocalread-onlycurrentFRM220-1000EAS/X RMON UTP 3 Transceiver Multicast Packets.
1.3.6.1.4.1.4756.20.300.40.1.326Columnf1000EASXUTP3TXUniLocalread-onlycurrentFRM220-1000EAS/X RMON UTP 3 Transceiver Unicast Packets.
1.3.6.1.4.1.4756.20.300.40.1.327Columnf1000EASXUTP3TXPauseLocalread-onlycurrentFRM220-1000EAS/X RMON UTP 3 Transceiver Pause Packets.
1.3.6.1.4.1.4756.20.300.40.1.328Columnf1000EASXUTP3TXCollisionLocalread-onlycurrentFRM220-1000EAS/X RMON UTP 3 Transceiver Collision Packets.
1.3.6.1.4.1.4756.20.300.40.1.329Columnf1000EASXUTP30OctetsLocalread-onlycurrentFRM220-1000EAS/X RMON UTP 3 Transceiver/Receiver 0~64 Octets.
1.3.6.1.4.1.4756.20.300.40.1.330Columnf1000EASXUTP365OctetsLocalread-onlycurrentFRM220-1000EAS/X RMON UTP 3 Transceiver/Receiver 65~127 Octets.
1.3.6.1.4.1.4756.20.300.40.1.331Columnf1000EASXUTP3128OctetsLocalread-onlycurrentFRM220-1000EAS/X RMON UTP 3 Transceiver/Receiver 128~255 Octets.
1.3.6.1.4.1.4756.20.300.40.1.332Columnf1000EASXUTP3256OctetsLocalread-onlycurrentFRM220-1000EAS/X RMON UTP 3 Transceiver/Receiver 256~511 Octets.
1.3.6.1.4.1.4756.20.300.40.1.333Columnf1000EASXUTP3512OctetsLocalread-onlycurrentFRM220-1000EAS/X RMON UTP 3 Transceiver/Receiver 512~1023 Octets.
1.3.6.1.4.1.4756.20.300.40.1.334Columnf1000EASXUTP31024OctetsLocalread-onlycurrentFRM220-1000EAS/X RMON UTP 3 Transceiver/Receiver 1024~Max Octets.
1.3.6.1.4.1.4756.20.300.40.1.335Columnf1000EASXUTP4RXOctetsLocalread-onlycurrentFRM220-1000EAS/X RMON UTP 4 Receiver Octets.
1.3.6.1.4.1.4756.20.300.40.1.336Columnf1000EASXUTP4RXPacketLocalread-onlycurrentFRM220-1000EAS/X RMON UTP 4 Receiver Packets.
1.3.6.1.4.1.4756.20.300.40.1.337Columnf1000EASXUTP4RXBroadLocalread-onlycurrentFRM220-1000EAS/X RMON UTP 4 Receiver Broadcast Packets.
1.3.6.1.4.1.4756.20.300.40.1.338Columnf1000EASXUTP4RXMultiLocalread-onlycurrentFRM220-1000EAS/X RMON UTP 4 Receiver Multicast Packets.
1.3.6.1.4.1.4756.20.300.40.1.339Columnf1000EASXUTP4RXUniLocalread-onlycurrentFRM220-1000EAS/X RMON UTP 4 Receiver Unicast Packets.
1.3.6.1.4.1.4756.20.300.40.1.340Columnf1000EASXUTP4RXPauseLocalread-onlycurrentFRM220-1000EAS/X RMON UTP 4 Receiver Pause Packets.
1.3.6.1.4.1.4756.20.300.40.1.341Columnf1000EASXUTP4RXFCSELocalread-onlycurrentFRM220-1000EAS/X RMON UTP 4 Receiver FCS Error Packets.
1.3.6.1.4.1.4756.20.300.40.1.342Columnf1000EASXUTP4RXUnderLocalread-onlycurrentFRM220-1000EAS/X RMON UTP 4 Receiver Under Packets.
1.3.6.1.4.1.4756.20.300.40.1.343Columnf1000EASXUTP4RXOverLocalread-onlycurrentFRM220-1000EAS/X RMON UTP 4 Receiver Over Packets.
1.3.6.1.4.1.4756.20.300.40.1.344Columnf1000EASXUTP4RXJabberLocalread-onlycurrentFRM220-1000EAS/X RMON UTP 4 Receiver Jabber Packets.
1.3.6.1.4.1.4756.20.300.40.1.345Columnf1000EASXUTP4TXOctetsLocalread-onlycurrentFRM220-1000EAS/X RMON UTP 4 Transceiver Octets.
1.3.6.1.4.1.4756.20.300.40.1.346Columnf1000EASXUTP4TXPacketLocalread-onlycurrentFRM220-1000EAS/X RMON UTP 4 Transceiver Packets.
1.3.6.1.4.1.4756.20.300.40.1.347Columnf1000EASXUTP4TXBroadLocalread-onlycurrentFRM220-1000EAS/X RMON UTP 4 Transceiver Broadcast Packets.
1.3.6.1.4.1.4756.20.300.40.1.348Columnf1000EASXUTP4TXMultiLocalread-onlycurrentFRM220-1000EAS/X RMON UTP 4 Transceiver Multicast Packets.
1.3.6.1.4.1.4756.20.300.40.1.349Columnf1000EASXUTP4TXUniLocalread-onlycurrentFRM220-1000EAS/X RMON UTP 4 Transceiver Unicast Packets.
1.3.6.1.4.1.4756.20.300.40.1.350Columnf1000EASXUTP4TXPauseLocalread-onlycurrentFRM220-1000EAS/X RMON UTP 4 Transceiver Pause Packets.
1.3.6.1.4.1.4756.20.300.40.1.351Columnf1000EASXUTP4TXCollisionLocalread-onlycurrentFRM220-1000EAS/X RMON UTP 4 Transceiver Collision Packets.
1.3.6.1.4.1.4756.20.300.40.1.352Columnf1000EASXUTP40OctetsLocalread-onlycurrentFRM220-1000EAS/X RMON UTP 4 Transceiver/Receiver 0~64 Octets.
1.3.6.1.4.1.4756.20.300.40.1.353Columnf1000EASXUTP465OctetsLocalread-onlycurrentFRM220-1000EAS/X RMON UTP 4 Transceiver/Receiver 65~127 Octets.
1.3.6.1.4.1.4756.20.300.40.1.354Columnf1000EASXUTP4128OctetsLocalread-onlycurrentFRM220-1000EAS/X RMON UTP 4 Transceiver/Receiver 128~255 Octets.
1.3.6.1.4.1.4756.20.300.40.1.355Columnf1000EASXUTP4256OctetsLocalread-onlycurrentFRM220-1000EAS/X RMON UTP 4 Transceiver/Receiver 256~511 Octets.
1.3.6.1.4.1.4756.20.300.40.1.356Columnf1000EASXUTP4512OctetsLocalread-onlycurrentFRM220-1000EAS/X RMON UTP 4 Transceiver/Receiver 512~1023 Octets.
1.3.6.1.4.1.4756.20.300.40.1.357Columnf1000EASXUTP41024OctetsLocalread-onlycurrentFRM220-1000EAS/X RMON UTP 4 Transceiver/Receiver 1024~Max Octets.
1.3.6.1.4.1.4756.20.300.40.1.358Columnf1000EASXFiber2ThresholdLocalread-writecurrentLocal device Fiber2 Threshold:
1.3.6.1.4.1.4756.20.300.40.1.359Columnf1000EASXFiber2SensitivityLocalread-writecurrentLocal device Fiber2 Sensitivity:
1.3.6.1.4.1.4756.20.300.40.1.360Columnf1000EASXFx1LBTLocalread-writecurrentFRM220-1000EAS/X Fiber 1 LoopBack Test: 0: Disable 1: Enable 2: Not Support
1.3.6.1.4.1.4756.20.300.40.1.361Columnf1000EASXFx2LBTLocalread-writecurrentFRM220-1000EAS/X Fiber 2 LoopBack Test: 0: Disable 1: Enable 2: Not Support
1.3.6.1.4.1.4756.20.300.40.1.362Columnf1000EASXUtp3LBTLocalread-writecurrentFRM220-1000EAS/X UTP 3 LoopBack Test: 0: Disable 1: Enable 2: Not Support
1.3.6.1.4.1.4756.20.300.40.1.363Columnf1000EASXUtp4LBTLocalread-writecurrentFRM220-1000EAS/X UTP 4 LoopBack Test: 0: Disable 1: Enable 2: Not Support
1.3.6.1.4.1.4756.20.301Nodef1000EASXRemoteACards
1.3.6.1.4.1.4756.20.301.40Tablef1000EASXRemoteATablenot-accessiblecurrentA list of RemoteA 1000EAS/X card entries.
1.3.6.1.4.1.4756.20.301.40.1Rowf1000EASXRemoteAEntrynot-accessiblecurrentAn entry containing management information applicable to a particular RemoteA f1000EASX card.
1.3.6.1.4.1.4756.20.301.40.1.1Columnf1000EASXChassisIndexRemoteAread-onlycurrentA unique value for each chassis ID. For CH20, it is the chassis ID. For CH08, it is always 0.
1.3.6.1.4.1.4756.20.301.40.1.2Columnf1000EASXSlotIndexRemoteAread-onlycurrentA unique value for each RemoteA card. It is the slot location number.
1.3.6.1.4.1.4756.20.301.40.1.3Columnf1000EASXCardHWVerRemoteAread-onlycurrentRemoteA device card hardware version x.xxx
1.3.6.1.4.1.4756.20.301.40.1.4Columnf1000EASXCardFWVerRemoteAread-onlycurrentRemoteA device card firmware version x.xxx
1.3.6.1.4.1.4756.20.301.40.1.5Columnf1000EASXCardCPLDVerRemoteAread-onlycurrentRemoteA device card CPLD version x.xxx
1.3.6.1.4.1.4756.20.301.40.1.6Columnf1000EASXCardFPGAVerRemoteAread-onlycurrentRemoteA device card FPGA version x.xxx
1.3.6.1.4.1.4756.20.301.40.1.7Columnf1000EASXModelRemoteAread-onlycurrentRemoteA 1000EAS/X Serial Type
1.3.6.1.4.1.4756.20.301.40.1.8Columnf1000EASXFiber1LinkRemoteAread-onlycurrentRemoteA device card fiber port 1 link status: 0:Down 1:Up
1.3.6.1.4.1.4756.20.301.40.1.9Columnf1000EASXFiber1OAMLoopedRemoteAread-onlycurrentRemoteA device card fiber port 1 OAM looped: 0:Off 1:on
1.3.6.1.4.1.4756.20.301.40.1.10Columnf1000EASXFiber1LBTestRemoteAread-writecurrentForce remote device card to do fiber port 1 LoopBack testing: 0:Off 1:Action
1.3.6.1.4.1.4756.20.301.40.1.11Columnf1000EASXFiber1OAMRLBStatusRemoteAread-onlycurrentRemote device card fiber port 1 LoopBack testing status: 0:Off 1:Ok 2:Fail
1.3.6.1.4.1.4756.20.301.40.1.12Columnf1000EASXFiber1RemoPwrAbRemoteAread-onlycurrentRemoteA device card fiber port 1 Remote Power status: 0:Abnormal 1:OK 2:None
1.3.6.1.4.1.4756.20.301.40.1.13Columnf1000EASXFiber1IngressRateRemoteAread-writecurrentRemoteA device card fiber 1 Ingress Rate Limit: 0 = Unlimit input format: 64k(K),100m(M),100 If doesn't input the unit, the default was Mega. Limite Rate : 64K…
1.3.6.1.4.1.4756.20.301.40.1.14Columnf1000EASXFiber1EgressRateRemoteAread-writecurrentRemoteA device card fiber 1 Egress Rate Limit: 0 = Unlimit input format: 64k(K),100m(M),100 If doesn't input the unit, the default was Mega. Limite Rate : 64K …
1.3.6.1.4.1.4756.20.301.40.1.15Columnf1000EASXFiber2LinkRemoteAread-onlycurrentRemoteA device card fiber port 2 link status: 0:Down 1:Up
1.3.6.1.4.1.4756.20.301.40.1.16Columnf1000EASXFiber2OAMLoopedRemoteAread-onlycurrentRemoteA device card fiber port 2 OAM looped: 0:Off 1:on
1.3.6.1.4.1.4756.20.301.40.1.17Columnf1000EASXFiber2LBTestRemoteAread-writecurrentForce remote device card to do fiber port 2 LoopBack testing: 0:Off 1:Action
1.3.6.1.4.1.4756.20.301.40.1.18Columnf1000EASXFiber2OAMRLBStatusRemoteAread-onlycurrentRemote device card fiber port 1 LoopBack testing status: 0:Off 1:Ok 2:Fail
1.3.6.1.4.1.4756.20.301.40.1.19Columnf1000EASXFiber2RemoPwrAbRemoteAread-onlycurrentRemoteA device card fiber port 2 Remote Power status: 0:Abnormal 1:OK 2:None
1.3.6.1.4.1.4756.20.301.40.1.20Columnf1000EASXFiber2IngressRateRemoteAread-writecurrentRemoteA device card fiber 2 Ingress Rate Limit: 0 = Unlimit input format: 64k(K),100m(M),100 If doesn't input the unit, the default was Mega. Limite Rate : 64K…
1.3.6.1.4.1.4756.20.301.40.1.21Columnf1000EASXFiber2EgressRateRemoteAread-writecurrentRemoteA device card fiber 2 Egress Rate Limit: 0 = Unlimit input format: 64k(K),100m(M),100 If doesn't input the unit, the default was Mega. Limite Rate : 64K …
1.3.6.1.4.1.4756.20.301.40.1.22Columnf1000EASXUtp3LinkRemoteAread-onlycurrentRemoteA device card UTP port 3 link status: 0:Down 1:Up
1.3.6.1.4.1.4756.20.301.40.1.23Columnf1000EASXUtp3NegoRemoteAread-writecurrentRemoteA device card UTP port 3 negotiation status: 0:Manual 1:Auto
1.3.6.1.4.1.4756.20.301.40.1.24Columnf1000EASXUtp3SpeedRemoteAread-writecurrentRemoteA device card UTP port 3 speed setting: 0:10 Base-T 1:100 Base-TX 2:1000 Base-TX
1.3.6.1.4.1.4756.20.301.40.1.25Columnf1000EASXUtp3DuplexRemoteAread-writecurrentRemoteA device card UTP port 3 duplex setting: 0:Half duplex mode 1:Full duplex mode
1.3.6.1.4.1.4756.20.301.40.1.26Columnf1000EASXUtp3SpeedStatusRemoteAread-onlycurrentRemoteA device card UTP port 3 speed status: 0:10 Base-T 1:100 Base-TX 2:1000 Base-TX
1.3.6.1.4.1.4756.20.301.40.1.27Columnf1000EASXUtp3DuplexStatusRemoteAread-onlycurrentRemoteA device card UTP port 3 duplex status: 0:Half duplex mode 1:Full duplex mode
1.3.6.1.4.1.4756.20.301.40.1.28Columnf1000EASXUtp3IngressRateRemoteAread-writecurrentRemoteA device card utp 3 Ingress Rate Limit: 0 = Unlimit input format: 64k(K),100m(M),100 If doesn't input the unit, the default was Mega. Limite Rate : 64K ~…
1.3.6.1.4.1.4756.20.301.40.1.29Columnf1000EASXUtp3EgressRateRemoteAread-writecurrentRemoteA device card utp 3 Egress Rate Limit: 0 = Unlimit input format: 64k(K),100m(M),100 If doesn't input the unit, the default was Mega. Limite Rate : 64K ~ …
1.3.6.1.4.1.4756.20.301.40.1.30Columnf1000EASXUtp4LinkRemoteAread-onlycurrentRemoteA device card UTP port 4 link status: 0:Down 1:Up
1.3.6.1.4.1.4756.20.301.40.1.31Columnf1000EASXUtp4NegoRemoteAread-writecurrentRemoteA device card UTP port 4 negotiation status: 0:Manual 1:Auto
1.3.6.1.4.1.4756.20.301.40.1.32Columnf1000EASXUtp4SpeedRemoteAread-writecurrentRemoteA device card UTP port 4 speed setting: 0:10 Base-T 1:100 Base-TX 2:1000 Base-TX
1.3.6.1.4.1.4756.20.301.40.1.33Columnf1000EASXUtp4DuplexRemoteAread-writecurrentRemoteA device card UTP port 4 duplex setting: 0:Half duplex mode 1:Full duplex mode
1.3.6.1.4.1.4756.20.301.40.1.34Columnf1000EASXUtp4SpeedStatusRemoteAread-onlycurrentRemoteA device card UTP port 4 speed status: 0:10 Base-T 1:100 Base-TX 2:1000 Base-TX
1.3.6.1.4.1.4756.20.301.40.1.35Columnf1000EASXUtp4DuplexStatusRemoteAread-onlycurrentRemoteA device card UTP port 4 duplex status: 0:Half duplex mode 1:Full duplex mode
1.3.6.1.4.1.4756.20.301.40.1.36Columnf1000EASXUtp4IngressRateRemoteAread-writecurrentRemoteA device card utp 4 Ingress Rate Limit: 0 = Unlimit input format: 64k(K),100m(M),100 If doesn't input the unit, the default was Mega. Limite Rate : 64K ~…
1.3.6.1.4.1.4756.20.301.40.1.37Columnf1000EASXUtp4EgressRateRemoteAread-writecurrentRemoteA device card utp 4 Egress Rate Limit: 0 = Unlimit input format: 64k(K),100m(M),100 If doesn't input the unit, the default was Mega. Limite Rate : 64K ~ …
1.3.6.1.4.1.4756.20.301.40.1.38Columnf1000EASXDeviceResetRemoteAread-writecurrentForce RemoteA device card to reset mode: 0:Off 1:Action
1.3.6.1.4.1.4756.20.301.40.1.39Columnf1000EASXUtp3ActiveRemoteAread-writecurrentRemoteA device UTP port 3 active mode: 0:Disable 1:Enable
1.3.6.1.4.1.4756.20.301.40.1.40Columnf1000EASXUtp4ActiveRemoteAread-writecurrentRemoteA device UTP port 4 active mode: 0:Disable 1:Enable
1.3.6.1.4.1.4756.20.301.40.1.41Columnf1000EASXOamChAModeRemoteAread-writecurrentRemoteA device OAM Channel A mode: 0:Disable 1:passive 2:Active
1.3.6.1.4.1.4756.20.301.40.1.42Columnf1000EASXOamChBModeRemoteAread-writecurrentRemoteA device OAM Channel B mode: 0:Disable 1:passive 2:Active
1.3.6.1.4.1.4756.20.301.40.1.43Columnf1000EASXOamMaxPDUsRemoteAread-writecurrentRemoteA device OAM max OAMPDU size: 60-1518 Octets
1.3.6.1.4.1.4756.20.301.40.1.44Columnf1000EASXFiber1AlsRemoteAread-writecurrentRemoteA device card port 1 Auto Laser Shutdown mode: 0:Disable 1:Enable
1.3.6.1.4.1.4756.20.301.40.1.45Columnf1000EASXFiber2AlsRemoteAread-writecurrentRemoteA device card port 2 Auto Laser Shutdown mode: 0:Disable 1:Enable
1.3.6.1.4.1.4756.20.301.40.1.46Columnf1000EASXPauseFrameRemoteAread-writecurrentRemoteA device card pause frame mode: 0:Disable 1:Enable
1.3.6.1.4.1.4756.20.301.40.1.47Columnf1000EASXFHRModeRemoteAread-writecurrentRemoteA device card FHR Mode: 0:Disable 1:Enable
1.3.6.1.4.1.4756.20.301.40.1.48Columnf1000EASXFiber1LLFDepLogiRemoteAread-writecurrentRemoteA device card port 1 Link Loss Forwarding depends boolean logic: 0:and 1:or
1.3.6.1.4.1.4756.20.301.40.1.49Columnf1000EASXFiber1LLFDepPort2RemoteAread-writecurrentRemoteA device card port 1 Link Loss Forwarding depends on port 2 Fiber Rx link: 0:don't care 1:selected
1.3.6.1.4.1.4756.20.301.40.1.50Columnf1000EASXFiber1LLFDepPort3RemoteAread-writecurrentRemoteA device card port 1 Link Loss Forwarding depends on port 3 Ethernet Rx link: 0:don't care 1:selected
1.3.6.1.4.1.4756.20.301.40.1.51Columnf1000EASXFiber1LLFDepPort4RemoteAread-writecurrentRemoteA device card port 1 Link Loss Forwarding depends on port 4 Ethernet Rx link: 0:don't care 1:selected
1.3.6.1.4.1.4756.20.301.40.1.52Columnf1000EASXFiber2LLFDepLogiRemoteAread-writecurrentRemoteA device card port 2 Link Loss Forwarding depends boolean logic: 0:and 1:or
1.3.6.1.4.1.4756.20.301.40.1.53Columnf1000EASXFiber2LLFDepPort1RemoteAread-writecurrentRemoteA device card port 2 Link Loss Forwarding depends on port 1 Fiber Rx link: 0:don't care 1:selected
1.3.6.1.4.1.4756.20.301.40.1.54Columnf1000EASXFiber2LLFDepPort3RemoteAread-writecurrentRemoteA device card port 2 Link Loss Forwarding depends on port 3 Ethernet Rx link: 0:don't care 1:selected
1.3.6.1.4.1.4756.20.301.40.1.55Columnf1000EASXFiber2LLFDepPort4RemoteAread-writecurrentRemoteA device card port 2 Link Loss Forwarding depends on port 4 Ethernet Rx link: 0:don't care 1:selected
1.3.6.1.4.1.4756.20.301.40.1.56Columnf1000EASXUtp3LLFDepLogiRemoteAread-writecurrentRemoteA device card port 3 Link Loss Forwarding depends boolean logic: 0:and 1:or
1.3.6.1.4.1.4756.20.301.40.1.57Columnf1000EASXUtp3LLFDepPort1RemoteAread-writecurrentRemoteA device card port 3 Link Loss Forwarding depends on port 1 Fiber Rx link: 0:don't care 1:selected
1.3.6.1.4.1.4756.20.301.40.1.58Columnf1000EASXUtp3LLFDepPort2RemoteAread-writecurrentRemoteA device card port 3 Link Loss Forwarding depends on port 2 Fiber Rx link: 0:don't care 1:selected
1.3.6.1.4.1.4756.20.301.40.1.59Columnf1000EASXUtp4LLFDepLogiRemoteAread-writecurrentRemoteA device card port 4 Link Loss Forwarding depends boolean logic: 0:and 1:or
1.3.6.1.4.1.4756.20.301.40.1.60Columnf1000EASXUtp4LLFDepPort1RemoteAread-writecurrentRemoteA device card port 4 Link Loss Forwarding depends on port 1 Fiber Rx link: 0:don't care 1:selected
1.3.6.1.4.1.4756.20.301.40.1.61Columnf1000EASXUtp4LLFDepPort2RemoteAread-writecurrentRemoteA device card port 4 Link Loss Forwarding depends on port 2 Fiber Rx link: 0:don't care 1:selected
1.3.6.1.4.1.4756.20.301.40.1.62Columnf1000EASXAdvanceFunsRemoteAread-writecurrentRemoteA device card Switch functions mode: 0:Normal 1:Port 1 and Port 2 Trunk Bandwidth 2G 2:Port 1 to Port 2 Mirror 4:port 1 and port 2 Redundancy 5:Static 80…
1.3.6.1.4.1.4756.20.301.40.1.63Columnf1000EASXFiber1InfoROM1RemoteAread-onlycurrentRemoteA device card port 1 INFORemoteOM information 1 valid: 0:Invalid 1:Valid
1.3.6.1.4.1.4756.20.301.40.1.64Columnf1000EASXFiber1InfoROM2RemoteAread-onlycurrentRemoteA device card port 1 INFORemoteOM information 2 valid: 0:Invalid 1:Valid(replacing D/D function
1.3.6.1.4.1.4756.20.301.40.1.65Columnf1000EASXFiber2InfoROM1RemoteAread-onlycurrentRemoteA device card port 2 INFORemoteOM information 1 valid: 0:Invalid 1:Valid
1.3.6.1.4.1.4756.20.301.40.1.66Columnf1000EASXFiber2InfoROM2RemoteAread-onlycurrentRemoteA device card port 2 INFORemoteOM information 2 valid: 0:Invalid 1:Valid(replacing D/D function)
1.3.6.1.4.1.4756.20.301.40.1.67Columnf1000EASXFiber1InfoSN1RemoteAread-onlycurrentRemoteA device card port 1 INFORemoteOM S/N 1
1.3.6.1.4.1.4756.20.301.40.1.68Columnf1000EASXFiber1InfoSN2RemoteAread-onlycurrentRemoteA device card port 1 INFORemoteOM S/N 2
1.3.6.1.4.1.4756.20.301.40.1.69Columnf1000EASXFiber2InfoSN1RemoteAread-onlycurrentRemoteA device card port 2 INFORemoteOM S/N 1
1.3.6.1.4.1.4756.20.301.40.1.70Columnf1000EASXFiber2InfoSN2RemoteAread-onlycurrentRemoteA device card port 2 INFORemoteOM S/N 2
1.3.6.1.4.1.4756.20.301.40.1.71Columnf1000EASXFiber1DDRemoteAread-onlycurrentRemoteA device card fiber port 1 Digital Diagnostic function: 0:No 1:Yes
1.3.6.1.4.1.4756.20.301.40.1.72Columnf1000EASXFiber1DDVendorRemoteAread-onlycurrentRemoteA device card fiber port 1 D/D information: Vendor name
1.3.6.1.4.1.4756.20.301.40.1.73Columnf1000EASXFiber1DDPartNoRemoteAread-onlycurrentRemoteA device card fiber port 1 D/D information: Vendor part number
1.3.6.1.4.1.4756.20.301.40.1.74Columnf1000EASXFiber1DDVendorSNRemoteAread-onlycurrentRemoteA device card fiber port 1 D/D information: Vendor Serial Number
1.3.6.1.4.1.4756.20.301.40.1.75Columnf1000EASXFiber1DDFiberTypeRemoteAread-onlycurrentRemoteA device card fiber port 1 D/D information: Fiber Type
1.3.6.1.4.1.4756.20.301.40.1.76Columnf1000EASXFiber1DDWaveLenRemoteAread-onlycurrentRemoteA device card fiber port 1 D/D information: Wave length
1.3.6.1.4.1.4756.20.301.40.1.77Columnf1000EASXFiber1DDWaveLen2RemoteAread-onlycurrentRemoteA device card fiber port 1 D/D information: Wave length 2
1.3.6.1.4.1.4756.20.301.40.1.78Columnf1000EASXFiber1DDLinkLenRemoteAread-onlycurrentRemoteA device card fiber port 1 D/D information: Link length
1.3.6.1.4.1.4756.20.301.40.1.79Columnf1000EASXFiber1DDLenUnitRemoteAread-onlycurrentRemoteA device card fiber port 1 D/D information: Length Unit
1.3.6.1.4.1.4756.20.301.40.1.80Columnf1000EASXFiber1DDStatusRemoteAread-onlycurrentRemoteA device card fiber port 1 D/D information: Status Support
1.3.6.1.4.1.4756.20.301.40.1.81Columnf1000EASXFiber1DDRxSensRemoteAread-onlycurrentRemoteA device card fiber port 1 D/D information: Rx Sensitivity
1.3.6.1.4.1.4756.20.301.40.1.82Columnf1000EASXFiber1DDTxPWRRemoteAread-onlycurrentRemoteA device card fiber port 1 D/D information: Tx power
1.3.6.1.4.1.4756.20.301.40.1.83Columnf1000EASXFiber1DDRxPWRRemoteAread-onlycurrentRemoteA device card fiber port 1 D/D information: Rx power
1.3.6.1.4.1.4756.20.301.40.1.84Columnf1000EASXFiber1DDTempRemoteAread-onlycurrentRemoteA device card fiber port 1 D/D information: Temperature in degree C
1.3.6.1.4.1.4756.20.301.40.1.85Columnf1000EASXFiber1DDPWRMarginRemoteAread-onlycurrentRemoteA device card fiber port 1 D/D information: Power margin
1.3.6.1.4.1.4756.20.301.40.1.86Columnf1000EASXFiber1DDPWRLossRemoteAread-onlycurrentRemoteA device card fiber port 1 D/D information: Power loss
1.3.6.1.4.1.4756.20.301.40.1.87Columnf1000EASXFiber2DDRemoteAread-onlycurrentRemoteA device card fiber port 2 Digital Diagnostic function: 0:No 1:Yes
1.3.6.1.4.1.4756.20.301.40.1.88Columnf1000EASXFiber2DDVendorRemoteAread-onlycurrentRemoteA device card fiber port 2 D/D information: Vendor name
1.3.6.1.4.1.4756.20.301.40.1.89Columnf1000EASXFiber2DDPartNoRemoteAread-onlycurrentRemoteA device card fiber port 2 D/D information: Vendor part number
1.3.6.1.4.1.4756.20.301.40.1.90Columnf1000EASXFiber2DDVendorSNRemoteAread-onlycurrentRemoteA device card fiber port 2 D/D information: Vendor Serial Number
1.3.6.1.4.1.4756.20.301.40.1.91Columnf1000EASXFiber2DDFiberTypeRemoteAread-onlycurrentRemoteA device card fiber port 2 D/D information: Fiber Type
1.3.6.1.4.1.4756.20.301.40.1.92Columnf1000EASXFiber2DDWaveLenRemoteAread-onlycurrentRemoteA device card fiber port 2 D/D information: Wave length
1.3.6.1.4.1.4756.20.301.40.1.93Columnf1000EASXFiber2DDWaveLen2RemoteAread-onlycurrentRemoteA device card fiber port 2 D/D information: Wave length 2
1.3.6.1.4.1.4756.20.301.40.1.94Columnf1000EASXFiber2DDLinkLenRemoteAread-onlycurrentRemoteA device card fiber port 2 D/D information: Link length
1.3.6.1.4.1.4756.20.301.40.1.95Columnf1000EASXFiber2DDLenUnitRemoteAread-onlycurrentRemoteA device card fiber port 2 D/D information: Length Unit
1.3.6.1.4.1.4756.20.301.40.1.96Columnf1000EASXFiber2DDStatusRemoteAread-onlycurrentRemoteA device card fiber port 2 D/D information: Status Support
1.3.6.1.4.1.4756.20.301.40.1.97Columnf1000EASXFiber2DDRxSensRemoteAread-onlycurrentRemoteA device card fiber port 2 D/D information: Rx Sensitivity
1.3.6.1.4.1.4756.20.301.40.1.98Columnf1000EASXFiber2DDTxPWRRemoteAread-onlycurrentRemoteA device card fiber port 2 D/D information: Tx power
1.3.6.1.4.1.4756.20.301.40.1.99Columnf1000EASXFiber2DDRxPWRRemoteAread-onlycurrentRemoteA device card fiber port 2 D/D information: Rx power
1.3.6.1.4.1.4756.20.301.40.1.100Columnf1000EASXFiber2DDTempRemoteAread-onlycurrentRemoteA device card fiber port 2 D/D information: Temperature in degree C
1.3.6.1.4.1.4756.20.301.40.1.101Columnf1000EASXFiber2DDPWRMarginRemoteAread-onlycurrentRemoteA device card fiber port 2 D/D information: Power margin
1.3.6.1.4.1.4756.20.301.40.1.102Columnf1000EASXFiber2DDPWRLossRemoteAread-onlycurrentRemoteA device card fiber port 2 D/D information: Power loss
1.3.6.1.4.1.4756.20.301.40.1.103Columnf1000EASXClrRMONCntsRemoteAread-writecurrentClear RemoteA device card RMON IN/OUT counters: 0:No action 1:Action
1.3.6.1.4.1.4756.20.301.40.1.104Columnf1000EASXFiber1RMONInRemoteAread-onlycurrentRemoteA device card port 1 RMON IN counter.
1.3.6.1.4.1.4756.20.301.40.1.105Columnf1000EASXFiber1RMONOutRemoteAread-onlycurrentRemoteA device card port 1 RMON OUT counter.
1.3.6.1.4.1.4756.20.301.40.1.106Columnf1000EASXFiber2RMONInRemoteAread-onlycurrentRemoteA device card port 2 RMON IN counter.
1.3.6.1.4.1.4756.20.301.40.1.107Columnf1000EASXFiber2RMONOutRemoteAread-onlycurrentRemoteA device card port 2 RMON OUT counter.
1.3.6.1.4.1.4756.20.301.40.1.108Columnf1000EASXUtp3RMONInRemoteAread-onlycurrentRemoteA device card port 3 RMON IN counter.
1.3.6.1.4.1.4756.20.301.40.1.109Columnf1000EASXUtp3RMONOutRemoteAread-onlycurrentRemoteA device card port 3 RMON OUT counter.
1.3.6.1.4.1.4756.20.301.40.1.110Columnf1000EASXUtp4RMONInRemoteAread-onlycurrentRemoteA device card port 4 RMON IN counter.
1.3.6.1.4.1.4756.20.301.40.1.111Columnf1000EASXUtp4RMONOutRemoteAread-onlycurrentRemoteA device card port 4 RMON OUT counter.
1.3.6.1.4.1.4756.20.301.40.1.112Columnf1000EASXClrOAMCntsRemoteAread-writecurrentClear RemoteA device card OAM counters: 0:No action 1:Action
1.3.6.1.4.1.4756.20.301.40.1.113Columnf1000EASXIpModeRemoteAread-writecurrentOn Rack Ip Mode: 0:Enable 1:Disable
1.3.6.1.4.1.4756.20.301.40.1.114Columnf1000EASXOamChATxRemoteAread-onlycurrentRemoteA device OAM Channel A TX OAMPDU frame count
1.3.6.1.4.1.4756.20.301.40.1.115Columnf1000EASXOamChARxRemoteAread-onlycurrentRemoteA device OAM Channel A RX OAMPDU frame count
1.3.6.1.4.1.4756.20.301.40.1.116Columnf1000EASXOamInfoChATxRemoteAread-onlycurrentRemoteA device OAM Channel A TX Information OAMPDU frame count
1.3.6.1.4.1.4756.20.301.40.1.117Columnf1000EASXOamInfoChARxRemoteAread-onlycurrentRemoteA device OAM Channel A RX Information OAMPDU frame count
1.3.6.1.4.1.4756.20.301.40.1.118Columnf1000EASXOamEventChATxRemoteAread-onlycurrentRemoteA device OAM Channel A TX Event OAMPDU frame count
1.3.6.1.4.1.4756.20.301.40.1.119Columnf1000EASXOamUniEvtChARxRemoteAread-onlycurrentRemoteA device OAM Channel A RX Unique Event OAMPDU frame count
1.3.6.1.4.1.4756.20.301.40.1.120Columnf1000EASXOamDupEvtChARxRemoteAread-onlycurrentRemoteA device OAM Channel A RX Duplicate Event OAMPDU frame count
1.3.6.1.4.1.4756.20.301.40.1.121Columnf1000EASXOamLbChATxRemoteAread-onlycurrentRemoteA device OAM Channel A TX Loopback Control OAMPDU frame count
1.3.6.1.4.1.4756.20.301.40.1.122Columnf1000EASXOamLbChARxRemoteAread-onlycurrentRemoteA device OAM Channel A RX Loopback Control OAMPDU frame count
1.3.6.1.4.1.4756.20.301.40.1.123Columnf1000EASXOamVarReqChATxRemoteAread-onlycurrentRemoteA device OAM Channel A TX Variable Request OAMPDU frame count
1.3.6.1.4.1.4756.20.301.40.1.124Columnf1000EASXOamVarReqChARxRemoteAread-onlycurrentRemoteA device OAM Channel A RX Variable Request OAMPDU frame count
1.3.6.1.4.1.4756.20.301.40.1.125Columnf1000EASXOamVarRspChATxRemoteAread-onlycurrentRemoteA device OAM Channel A TX Variable Response OAMPDU frame count
1.3.6.1.4.1.4756.20.301.40.1.126Columnf1000EASXOamVarRspChARxRemoteAread-onlycurrentRemoteA device OAM Channel A RX Variable Response OAMPDU frame count
1.3.6.1.4.1.4756.20.301.40.1.127Columnf1000EASXOamOuiChATxRemoteAread-onlycurrentRemoteA device OAM Channel A TX OUI OAMPDU frame count
1.3.6.1.4.1.4756.20.301.40.1.128Columnf1000EASXOamOuiChARxRemoteAread-onlycurrentRemoteA device OAM Channel A RX OUI OAMPDU frame count
1.3.6.1.4.1.4756.20.301.40.1.129Columnf1000EASXOamUnknowChARxRemoteAread-onlycurrentRemoteA device OAM Channel A RX Unsupported OAMPDU frame count
1.3.6.1.4.1.4756.20.301.40.1.130Columnf1000EASXOamChBTxRemoteAread-onlycurrentRemoteA device OAM Channel B TX OAMPDU frame count
1.3.6.1.4.1.4756.20.301.40.1.131Columnf1000EASXOamChBRxRemoteAread-onlycurrentRemoteA device OAM Channel B RX OAMPDU frame count
1.3.6.1.4.1.4756.20.301.40.1.132Columnf1000EASXOamInfoChBTxRemoteAread-onlycurrentRemoteA device OAM Channel B TX Information OAMPDU frame count
1.3.6.1.4.1.4756.20.301.40.1.133Columnf1000EASXOamInfoChBRxRemoteAread-onlycurrentRemoteA device OAM Channel B RX Information OAMPDU frame count
1.3.6.1.4.1.4756.20.301.40.1.134Columnf1000EASXOamEventChBTxRemoteAread-onlycurrentRemoteA device OAM Channel B TX Event OAMPDU frame count
1.3.6.1.4.1.4756.20.301.40.1.135Columnf1000EASXOamUniEvtChBRxRemoteAread-onlycurrentRemoteA device OAM Channel B RX Unique Event OAMPDU frame count
1.3.6.1.4.1.4756.20.301.40.1.136Columnf1000EASXOamDupEvtChBRxRemoteAread-onlycurrentRemoteA device OAM Channel B RX Duplicate Event OAMPDU frame count
1.3.6.1.4.1.4756.20.301.40.1.137Columnf1000EASXOamLbChBTxRemoteAread-onlycurrentRemoteA device OAM Channel B TX Loopback Control OAMPDU frame count
1.3.6.1.4.1.4756.20.301.40.1.138Columnf1000EASXOamLbChBRxRemoteAread-onlycurrentRemoteA device OAM Channel B RX Loopback Control OAMPDU frame count
1.3.6.1.4.1.4756.20.301.40.1.139Columnf1000EASXOamVarReqChBTxRemoteAread-onlycurrentRemoteA device OAM Channel B TX Variable Request OAMPDU frame count
1.3.6.1.4.1.4756.20.301.40.1.140Columnf1000EASXOamVarReqChBRxRemoteAread-onlycurrentRemoteA device OAM Channel B RX Variable Request OAMPDU frame count
1.3.6.1.4.1.4756.20.301.40.1.141Columnf1000EASXOamVarRspChBTxRemoteAread-onlycurrentRemoteA device OAM Channel B TX Variable Response OAMPDU frame count
1.3.6.1.4.1.4756.20.301.40.1.142Columnf1000EASXOamVarRspChBRxRemoteAread-onlycurrentRemoteA device OAM Channel B RX Variable Response OAMPDU frame count
1.3.6.1.4.1.4756.20.301.40.1.143Columnf1000EASXOamOuiChBTxRemoteAread-onlycurrentRemoteA device OAM Channel B TX OUI OAMPDU frame count
1.3.6.1.4.1.4756.20.301.40.1.144Columnf1000EASXOamOuiChBRxRemoteAread-onlycurrentRemoteA device OAM Channel B RX OUI OAMPDU frame count
1.3.6.1.4.1.4756.20.301.40.1.145Columnf1000EASXOamUnknowChBRxRemoteAread-onlycurrentRemoteA device OAM Channel B RX Unsupported OAMPDU frame count
1.3.6.1.4.1.4756.20.301.40.1.146Columnf1000EASXFiber1SpeedRemoteAread-onlycurrentRemoteA device Fiber 1 speed : 0:1000Auto 1:1000FDX 2:100FDX
1.3.6.1.4.1.4756.20.301.40.1.147Columnf1000EASXFiber2SpeedRemoteAread-onlycurrentRemoteA device Fiber 2 speed : 0:1000Auto 1:1000FDX 2:100FDX
1.3.6.1.4.1.4756.20.301.40.1.148Columnf1000EASXMacLearningRemoteAread-writecurrentRemoteA device Mac learning : 0:Disable 1:Enable
1.3.6.1.4.1.4756.20.301.40.1.149Columnf1000EASXFiber1VLANRemoteAread-writecurrentRemoteA device Fiber 1 VLAN group : 0:Group A 1:Group B
1.3.6.1.4.1.4756.20.301.40.1.150Columnf1000EASXFiber2VLANRemoteAread-writecurrentRemoteA device Fiber 2 VLAN group : 0:Group A 1:Group B
1.3.6.1.4.1.4756.20.301.40.1.151Columnf1000EASXUtp3VLANRemoteAread-writecurrentRemoteA device UTP 3 VLAN group : 0:Group A 1:Group B
1.3.6.1.4.1.4756.20.301.40.1.152Columnf1000EASXUtp4VLANRemoteAread-writecurrentRemoteA device UTP 4 VLAN group : 0:Group A 1:Group B
1.3.6.1.4.1.4756.20.301.40.1.153Columnf1000EASXManagementRemoteAread-writecurrentRemoteA device management : 0:Group A 1:Group B 2:Group A+B
1.3.6.1.4.1.4756.20.301.40.1.154Columnf1000EASXRedundancyModeRemoteAread-writecurrentRemoteA device redundancy mode : 0:Auto 1:Manual Fiber 1 2:Manual Fiber 2 3:No Reverse 4:Link Budget
1.3.6.1.4.1.4756.20.301.40.1.155Columnf1000EASXPortVLANRemoteAread-writecurrentRemoteA device redundancy mode : 0:Disalbe 1:Enable
1.3.6.1.4.1.4756.20.301.40.1.156Columnf1000EASXRemoteTLPTRemoteAread-writecurrentRemoteA device redundancy mode : 0:Disalbe 1:Remote A 2:Remote B 3:Remote A&B 4:Remote A/3; Remote B/4
1.3.6.1.4.1.4756.20.301.40.1.157Columnf1000EASXManagementVIDRemoteAread-writecurrentRemoteA device Management VID :
1.3.6.1.4.1.4756.20.301.40.1.158Columnf1000EASXThresholdRemoteAread-writecurrentRemoteA device Threshold:
1.3.6.1.4.1.4756.20.301.40.1.159Columnf1000EASXSensitivityRemoteAread-writecurrentRemoteA device Sensitivity:
1.3.6.1.4.1.4756.20.301.40.1.160Columnf1000EASXTagTypeRemoteAread-writecurrentRemoteA device Tag Type (HEX) :
1.3.6.1.4.1.4756.20.301.40.1.161Columnf1000EASXPort1VIDRemoteAread-writecurrentRemoteA device Port 1 VID :
1.3.6.1.4.1.4756.20.301.40.1.162Columnf1000EASXPort2VIDRemoteAread-writecurrentRemoteA device Port 2 VID :
1.3.6.1.4.1.4756.20.301.40.1.163Columnf1000EASXPort3VIDRemoteAread-writecurrentRemoteA device Port 3 VID :
1.3.6.1.4.1.4756.20.301.40.1.164Columnf1000EASXPort4VIDRemoteAread-writecurrentRemoteA device Port 4 VID :
1.3.6.1.4.1.4756.20.301.40.1.165Columnf1000EASXPort1QinQRemoteAread-writecurrentRemoteA device Port 1 Q in Q Support : 1:Disable 2:Enable
1.3.6.1.4.1.4756.20.301.40.1.166Columnf1000EASXPort2QinQRemoteAread-writecurrentRemoteA device Port 2 Q in Q Support : 1:Disable 2:Enable
1.3.6.1.4.1.4756.20.301.40.1.167Columnf1000EASXPort3QinQRemoteAread-writecurrentRemoteA device Port 3 Q in Q Support : 1:Disable 2:Enable
1.3.6.1.4.1.4756.20.301.40.1.168Columnf1000EASXPort4QinQRemoteAread-writecurrentRemoteA device Port 4 Q in Q Support : 1:Disable 2:Enable
1.3.6.1.4.1.4756.20.301.40.1.169Columnf1000EASXVID1RemoteAread-writecurrentRemoteA device VID 1:
1.3.6.1.4.1.4756.20.301.40.1.170Columnf1000EASXVID2RemoteAread-writecurrentRemoteA device VID 2:
1.3.6.1.4.1.4756.20.301.40.1.171Columnf1000EASXVID3RemoteAread-writecurrentRemoteA device VID 3:
1.3.6.1.4.1.4756.20.301.40.1.172Columnf1000EASXVID4RemoteAread-writecurrentRemoteA device VID 4:
1.3.6.1.4.1.4756.20.301.40.1.173Columnf1000EASXVID5RemoteAread-writecurrentRemoteA device VID 5:
1.3.6.1.4.1.4756.20.301.40.1.174Columnf1000EASXVID6RemoteAread-writecurrentRemoteA device VID 6:
1.3.6.1.4.1.4756.20.301.40.1.175Columnf1000EASXVID7RemoteAread-writecurrentRemoteA device VID 7:
1.3.6.1.4.1.4756.20.301.40.1.176Columnf1000EASXVID8RemoteAread-writecurrentRemoteA device VID 8:
1.3.6.1.4.1.4756.20.301.40.1.177Columnf1000EASXVID9RemoteAread-writecurrentRemoteA device VID 9:
1.3.6.1.4.1.4756.20.301.40.1.178Columnf1000EASXVID10RemoteAread-writecurrentRemoteA device VID 10:
1.3.6.1.4.1.4756.20.301.40.1.179Columnf1000EASXVID11RemoteAread-writecurrentRemoteA device VID 11:
1.3.6.1.4.1.4756.20.301.40.1.180Columnf1000EASXVID12RemoteAread-writecurrentRemoteA device VID 12:
1.3.6.1.4.1.4756.20.301.40.1.181Columnf1000EASXVID13RemoteAread-writecurrentRemoteA device VID 13:
1.3.6.1.4.1.4756.20.301.40.1.182Columnf1000EASXVID14RemoteAread-writecurrentRemoteA device VID 14:
1.3.6.1.4.1.4756.20.301.40.1.183Columnf1000EASXVID15RemoteAread-writecurrentRemoteA device VID 15:
1.3.6.1.4.1.4756.20.301.40.1.184Columnf1000EASXVID16RemoteAread-writecurrentRemoteA device VID 16:
1.3.6.1.4.1.4756.20.301.40.1.185Columnf1000EASXPort1Member1RemoteAread-writecurrentRemoteA device card port 1 member: 0:Unmodify 1:Untagged 2:Tagged 3:Nonmember
1.3.6.1.4.1.4756.20.301.40.1.186Columnf1000EASXPort1Member2RemoteAread-writecurrentRemoteA device card port 1 member 2: 0:Unmodify 1:Untagged 2:Tagged 3:Nonmember
1.3.6.1.4.1.4756.20.301.40.1.187Columnf1000EASXPort1Member3RemoteAread-writecurrentRemoteA device card port 1 member 3: 0:Unmodify 1:Untagged 2:Tagged 3:Nonmember
1.3.6.1.4.1.4756.20.301.40.1.188Columnf1000EASXPort1Member4RemoteAread-writecurrentRemoteA device card port 1 member 4: 0:Unmodify 1:Untagged 2:Tagged 3:Nonmember
1.3.6.1.4.1.4756.20.301.40.1.189Columnf1000EASXPort1Member5RemoteAread-writecurrentRemoteA device card port 1 member 5: 0:Unmodify 1:Untagged 2:Tagged 3:Nonmember
1.3.6.1.4.1.4756.20.301.40.1.190Columnf1000EASXPort1Member6RemoteAread-writecurrentRemoteA device card port 1 member 6: 0:Unmodify 1:Untagged 2:Tagged 3:Nonmember
1.3.6.1.4.1.4756.20.301.40.1.191Columnf1000EASXPort1Member7RemoteAread-writecurrentRemoteA device card port 1 member 7: 0:Unmodify 1:Untagged 2:Tagged 3:Nonmember
1.3.6.1.4.1.4756.20.301.40.1.192Columnf1000EASXPort1Member8RemoteAread-writecurrentRemoteA device card port 1 member 8: 0:Unmodify 1:Untagged 2:Tagged 3:Nonmember
1.3.6.1.4.1.4756.20.301.40.1.193Columnf1000EASXPort1Member9RemoteAread-writecurrentRemoteA device card port 1 member 9: 0:Unmodify 1:Untagged 2:Tagged 3:Nonmember
1.3.6.1.4.1.4756.20.301.40.1.194Columnf1000EASXPort1Member10RemoteAread-writecurrentRemoteA device card port 1 member 10: 0:Unmodify 1:Untagged 2:Tagged 3:Nonmember
1.3.6.1.4.1.4756.20.301.40.1.195Columnf1000EASXPort1Member11RemoteAread-writecurrentRemoteA device card port 1 member 11: 0:Unmodify 1:Untagged 2:Tagged 3:Nonmember
1.3.6.1.4.1.4756.20.301.40.1.196Columnf1000EASXPort1Member12RemoteAread-writecurrentRemoteA device card port 1 member 12: 0:Unmodify 1:Untagged 2:Tagged 3:Nonmember
1.3.6.1.4.1.4756.20.301.40.1.197Columnf1000EASXPort1Member13RemoteAread-writecurrentRemoteA device card port 1 member 13: 0:Unmodify 1:Untagged 2:Tagged 3:Nonmember
1.3.6.1.4.1.4756.20.301.40.1.198Columnf1000EASXPort1Member14RemoteAread-writecurrentRemoteA device card port 1 member 14: 0:Unmodify 1:Untagged 2:Tagged 3:Nonmember
1.3.6.1.4.1.4756.20.301.40.1.199Columnf1000EASXPort1Member15RemoteAread-writecurrentRemoteA device card port 1 member 15: 0:Unmodify 1:Untagged 2:Tagged 3:Nonmember
1.3.6.1.4.1.4756.20.301.40.1.200Columnf1000EASXPort1Member16RemoteAread-writecurrentRemoteA device card port 1 member 16: 0:Unmodify 1:Untagged 2:Tagged 3:Nonmember
1.3.6.1.4.1.4756.20.301.40.1.201Columnf1000EASXPort2Member1RemoteAread-writecurrentRemoteA device card port 2 member: 0:Unmodify 1:Untagged 2:Tagged 3:Nonmember
1.3.6.1.4.1.4756.20.301.40.1.202Columnf1000EASXPort2Member2RemoteAread-writecurrentRemoteA device card port 2 member 2: 0:Unmodify 1:Untagged 2:Tagged 3:Nonmember
1.3.6.1.4.1.4756.20.301.40.1.203Columnf1000EASXPort2Member3RemoteAread-writecurrentRemoteA device card port 2 member 3: 0:Unmodify 1:Untagged 2:Tagged 3:Nonmember
1.3.6.1.4.1.4756.20.301.40.1.204Columnf1000EASXPort2Member4RemoteAread-writecurrentRemoteA device card port 2 member 4: 0:Unmodify 1:Untagged 2:Tagged 3:Nonmember
1.3.6.1.4.1.4756.20.301.40.1.205Columnf1000EASXPort2Member5RemoteAread-writecurrentRemoteA device card port 2 member 5: 0:Unmodify 1:Untagged 2:Tagged 3:Nonmember
1.3.6.1.4.1.4756.20.301.40.1.206Columnf1000EASXPort2Member6RemoteAread-writecurrentRemoteA device card port 2 member 6: 0:Unmodify 1:Untagged 2:Tagged 3:Nonmember
1.3.6.1.4.1.4756.20.301.40.1.207Columnf1000EASXPort2Member7RemoteAread-writecurrentRemoteA device card port 2 member 7: 0:Unmodify 1:Untagged 2:Tagged 3:Nonmember
1.3.6.1.4.1.4756.20.301.40.1.208Columnf1000EASXPort2Member8RemoteAread-writecurrentRemoteA device card port 2 member 8: 0:Unmodify 1:Untagged 2:Tagged 3:Nonmember
1.3.6.1.4.1.4756.20.301.40.1.209Columnf1000EASXPort2Member9RemoteAread-writecurrentRemoteA device card port 2 member 9: 0:Unmodify 1:Untagged 2:Tagged 3:Nonmember
1.3.6.1.4.1.4756.20.301.40.1.210Columnf1000EASXPort2Member10RemoteAread-writecurrentRemoteA device card port 2 member 10: 0:Unmodify 1:Untagged 2:Tagged 3:Nonmember
1.3.6.1.4.1.4756.20.301.40.1.211Columnf1000EASXPort2Member11RemoteAread-writecurrentRemoteA device card port 2 member 11: 0:Unmodify 1:Untagged 2:Tagged 3:Nonmember
1.3.6.1.4.1.4756.20.301.40.1.212Columnf1000EASXPort2Member12RemoteAread-writecurrentRemoteA device card port 2 member 12: 0:Unmodify 1:Untagged 2:Tagged 3:Nonmember
1.3.6.1.4.1.4756.20.301.40.1.213Columnf1000EASXPort2Member13RemoteAread-writecurrentRemoteA device card port 2 member 13: 0:Unmodify 1:Untagged 2:Tagged 3:Nonmember
1.3.6.1.4.1.4756.20.301.40.1.214Columnf1000EASXPort2Member14RemoteAread-writecurrentRemoteA device card port 2 member 14: 0:Unmodify 1:Untagged 2:Tagged 3:Nonmember
1.3.6.1.4.1.4756.20.301.40.1.215Columnf1000EASXPort2Member15RemoteAread-writecurrentRemoteA device card port 2 member 15: 0:Unmodify 1:Untagged 2:Tagged 3:Nonmember
1.3.6.1.4.1.4756.20.301.40.1.216Columnf1000EASXPort2Member16RemoteAread-writecurrentRemoteA device card port 2 member 16: 0:Unmodify 1:Untagged 2:Tagged 3:Nonmember
1.3.6.1.4.1.4756.20.301.40.1.217Columnf1000EASXPort3Member1RemoteAread-writecurrentRemoteA device card port 3 member: 0:Unmodify 1:Untagged 2:Tagged 3:Nonmember
1.3.6.1.4.1.4756.20.301.40.1.218Columnf1000EASXPort3Member2RemoteAread-writecurrentRemoteA device card port 3 member 2: 0:Unmodify 1:Untagged 2:Tagged 3:Nonmember
1.3.6.1.4.1.4756.20.301.40.1.219Columnf1000EASXPort3Member3RemoteAread-writecurrentRemoteA device card port 3 member 3: 0:Unmodify 1:Untagged 2:Tagged 3:Nonmember
1.3.6.1.4.1.4756.20.301.40.1.220Columnf1000EASXPort3Member4RemoteAread-writecurrentRemoteA device card port 3 member 4: 0:Unmodify 1:Untagged 2:Tagged 3:Nonmember
1.3.6.1.4.1.4756.20.301.40.1.221Columnf1000EASXPort3Member5RemoteAread-writecurrentRemoteA device card port 3 member 5: 0:Unmodify 1:Untagged 2:Tagged 3:Nonmember
1.3.6.1.4.1.4756.20.301.40.1.222Columnf1000EASXPort3Member6RemoteAread-writecurrentRemoteA device card port 3 member 6: 0:Unmodify 1:Untagged 2:Tagged 3:Nonmember
1.3.6.1.4.1.4756.20.301.40.1.223Columnf1000EASXPort3Member7RemoteAread-writecurrentRemoteA device card port 3 member 7: 0:Unmodify 1:Untagged 2:Tagged 3:Nonmember
1.3.6.1.4.1.4756.20.301.40.1.224Columnf1000EASXPort3Member8RemoteAread-writecurrentRemoteA device card port 3 member 8: 0:Unmodify 1:Untagged 2:Tagged 3:Nonmember
1.3.6.1.4.1.4756.20.301.40.1.225Columnf1000EASXPort3Member9RemoteAread-writecurrentRemoteA device card port 3 member 9: 0:Unmodify 1:Untagged 2:Tagged 3:Nonmember
1.3.6.1.4.1.4756.20.301.40.1.226Columnf1000EASXPort3Member10RemoteAread-writecurrentRemoteA device card port 3 member 10: 0:Unmodify 1:Untagged 2:Tagged 3:Nonmember
1.3.6.1.4.1.4756.20.301.40.1.227Columnf1000EASXPort3Member11RemoteAread-writecurrentRemoteA device card port 3 member 11: 0:Unmodify 1:Untagged 2:Tagged 3:Nonmember
1.3.6.1.4.1.4756.20.301.40.1.228Columnf1000EASXPort3Member12RemoteAread-writecurrentRemoteA device card port 3 member 12: 0:Unmodify 1:Untagged 2:Tagged 3:Nonmember
1.3.6.1.4.1.4756.20.301.40.1.229Columnf1000EASXPort3Member13RemoteAread-writecurrentRemoteA device card port 3 member 13: 0:Unmodify 1:Untagged 2:Tagged 3:Nonmember
1.3.6.1.4.1.4756.20.301.40.1.230Columnf1000EASXPort3Member14RemoteAread-writecurrentRemoteA device card port 3 member 14: 0:Unmodify 1:Untagged 2:Tagged 3:Nonmember
1.3.6.1.4.1.4756.20.301.40.1.231Columnf1000EASXPort3Member15RemoteAread-writecurrentRemoteA device card port 3 member 15: 0:Unmodify 1:Untagged 2:Tagged 3:Nonmember
1.3.6.1.4.1.4756.20.301.40.1.232Columnf1000EASXPort3Member16RemoteAread-writecurrentRemoteA device card port 3 member 16: 0:Unmodify 1:Untagged 2:Tagged 3:Nonmember
1.3.6.1.4.1.4756.20.301.40.1.233Columnf1000EASXPort4Member1RemoteAread-writecurrentRemoteA device card port 4 member: 0:Unmodify 1:Untagged 2:Tagged 3:Nonmember
1.3.6.1.4.1.4756.20.301.40.1.234Columnf1000EASXPort4Member2RemoteAread-writecurrentRemoteA device card port 4 member 2: 0:Unmodify 1:Untagged 2:Tagged 3:Nonmember
1.3.6.1.4.1.4756.20.301.40.1.235Columnf1000EASXPort4Member3RemoteAread-writecurrentRemoteA device card port 4 member 3: 0:Unmodify 1:Untagged 2:Tagged 3:Nonmember
1.3.6.1.4.1.4756.20.301.40.1.236Columnf1000EASXPort4Member4RemoteAread-writecurrentRemoteA device card port 4 member 4: 0:Unmodify 1:Untagged 2:Tagged 3:Nonmember
1.3.6.1.4.1.4756.20.301.40.1.237Columnf1000EASXPort4Member5RemoteAread-writecurrentRemoteA device card port 4 member 5: 0:Unmodify 1:Untagged 2:Tagged 3:Nonmember
1.3.6.1.4.1.4756.20.301.40.1.238Columnf1000EASXPort4Member6RemoteAread-writecurrentRemoteA device card port 4 member 6: 0:Unmodify 1:Untagged 2:Tagged 3:Nonmember
1.3.6.1.4.1.4756.20.301.40.1.239Columnf1000EASXPort4Member7RemoteAread-writecurrentRemoteA device card port 4 member 7: 0:Unmodify 1:Untagged 2:Tagged 3:Nonmember
1.3.6.1.4.1.4756.20.301.40.1.240Columnf1000EASXPort4Member8RemoteAread-writecurrentRemoteA device card port 4 member 8: 0:Unmodify 1:Untagged 2:Tagged 3:Nonmember
1.3.6.1.4.1.4756.20.301.40.1.241Columnf1000EASXPort4Member9RemoteAread-writecurrentRemoteA device card port 4 member 9: 0:Unmodify 1:Untagged 2:Tagged 3:Nonmember
1.3.6.1.4.1.4756.20.301.40.1.242Columnf1000EASXPort4Member10RemoteAread-writecurrentRemoteA device card port 4 member 10: 0:Unmodify 1:Untagged 2:Tagged 3:Nonmember
1.3.6.1.4.1.4756.20.301.40.1.243Columnf1000EASXPort4Member11RemoteAread-writecurrentRemoteA device card port 4 member 11: 0:Unmodify 1:Untagged 2:Tagged 3:Nonmember
1.3.6.1.4.1.4756.20.301.40.1.244Columnf1000EASXPort4Member12RemoteAread-writecurrentRemoteA device card port 4 member 12: 0:Unmodify 1:Untagged 2:Tagged 3:Nonmember
1.3.6.1.4.1.4756.20.301.40.1.245Columnf1000EASXPort4Member13RemoteAread-writecurrentRemoteA device card port 4 member 13: 0:Unmodify 1:Untagged 2:Tagged 3:Nonmember
1.3.6.1.4.1.4756.20.301.40.1.246Columnf1000EASXPort4Member14RemoteAread-writecurrentRemoteA device card port 4 member 14: 0:Unmodify 1:Untagged 2:Tagged 3:Nonmember
1.3.6.1.4.1.4756.20.301.40.1.247Columnf1000EASXPort4Member15RemoteAread-writecurrentRemoteA device card port 4 member 15: 0:Unmodify 1:Untagged 2:Tagged 3:Nonmember
1.3.6.1.4.1.4756.20.301.40.1.248Columnf1000EASXPort4Member16RemoteAread-writecurrentRemoteA device card port 4 member 16: 0:Unmodify 1:Untagged 2:Tagged 3:Nonmember
1.3.6.1.4.1.4756.20.301.40.1.249Columnf1000EASXIpAddressRemoteAread-writecurrentRemoteA device IP address
1.3.6.1.4.1.4756.20.301.40.1.250Columnf1000EASXNetMaskRemoteAread-writecurrentRemoteA device Netmask
1.3.6.1.4.1.4756.20.301.40.1.251Columnf1000EASXGateWayRemoteAread-writecurrentRemoteA device Gateway
1.3.6.1.4.1.4756.20.301.40.1.252Columnf1000EASXSetDefaultRemoteAread-writecurrentRemoteA device set to default
1.3.6.1.4.1.4756.20.301.40.1.253Columnf1000EASXFx1LinkAlarmRemoteAread-writecurrentRemoteA device fiber 1 link alarm 0:Disable 1:Enable
1.3.6.1.4.1.4756.20.301.40.1.254Columnf1000EASXFx2LinkAlarmRemoteAread-writecurrentRemoteA device fiber 2 link alarm 0:Disable 1:Enable
1.3.6.1.4.1.4756.20.301.40.1.255Columnf1000EASXUtp3LinkAlarmRemoteAread-writecurrentRemoteA device utp 3 link alarm 0:Disable 1:Enable
1.3.6.1.4.1.4756.20.301.40.1.256Columnf1000EASXUtp4LinkAlarmRemoteAread-writecurrentRemoteA device utp 4 link alarm 0:Disable 1:Enable
1.3.6.1.4.1.4756.20.301.40.1.257Columnf1000EASXFiber1FEFRemoteAread-onlycurrentRemoteA device card fiber1 port FEF status: 0:Off 1:Detected
1.3.6.1.4.1.4756.20.301.40.1.258Columnf1000EASXFiber2FEFRemoteAread-onlycurrentRemoteA device card fiber2 port FEF status: 0:Off 1:Detected
1.3.6.1.4.1.4756.20.301.40.1.259Columnf1000EASXFX1RXOctetsRemoteAread-onlycurrentFRM220-1000EAS/X RMON Fiber 1 Receiver Octets.
1.3.6.1.4.1.4756.20.301.40.1.260Columnf1000EASXFX1RXPacketRemoteAread-onlycurrentFRM220-1000EAS/X RMON Fiber 1 Receiver Packets.
1.3.6.1.4.1.4756.20.301.40.1.261Columnf1000EASXFX1RXBroadRemoteAread-onlycurrentFRM220-1000EAS/X RMON Fiber 1 Receiver Broadcast Packets.
1.3.6.1.4.1.4756.20.301.40.1.262Columnf1000EASXFX1RXMultiRemoteAread-onlycurrentFRM220-1000EAS/X RMON Fiber 1 Receiver Multicast Packets.
1.3.6.1.4.1.4756.20.301.40.1.263Columnf1000EASXFX1RXUniRemoteAread-onlycurrentFRM220-1000EAS/X RMON Fiber 1 Receiver Unicast Packets.
1.3.6.1.4.1.4756.20.301.40.1.264Columnf1000EASXFX1RXPauseRemoteAread-onlycurrentFRM220-1000EAS/X RMON Fiber 1 Receiver Pause Packets.
1.3.6.1.4.1.4756.20.301.40.1.265Columnf1000EASXFX1RXFCSERemoteAread-onlycurrentFRM220-1000EAS/X RMON Fiber 1 Receiver FCS Error Packets.
1.3.6.1.4.1.4756.20.301.40.1.266Columnf1000EASXFX1RXUnderRemoteAread-onlycurrentFRM220-1000EAS/X RMON Fiber 1 Receiver Under Packets.
1.3.6.1.4.1.4756.20.301.40.1.267Columnf1000EASXFX1RXOverRemoteAread-onlycurrentFRM220-1000EAS/X RMON Fiber 1 Receiver Over Packets.
1.3.6.1.4.1.4756.20.301.40.1.268Columnf1000EASXFX1RXJabberRemoteAread-onlycurrentFRM220-1000EAS/X RMON Fiber 1 Receiver Jabber Packets.
1.3.6.1.4.1.4756.20.301.40.1.269Columnf1000EASXFX1TXOctetsRemoteAread-onlycurrentFRM220-1000EAS/X RMON Fiber 1 Transceiver Octets.
1.3.6.1.4.1.4756.20.301.40.1.270Columnf1000EASXFX1TXPacketRemoteAread-onlycurrentFRM220-1000EAS/X RMON Fiber 1 Transceiver Packets.
1.3.6.1.4.1.4756.20.301.40.1.271Columnf1000EASXFX1TXBroadRemoteAread-onlycurrentFRM220-1000EAS/X RMON Fiber 1 Transceiver Broadcast Packets.
1.3.6.1.4.1.4756.20.301.40.1.272Columnf1000EASXFX1TXMultiRemoteAread-onlycurrentFRM220-1000EAS/X RMON Fiber 1 Transceiver Multicast Packets.
1.3.6.1.4.1.4756.20.301.40.1.273Columnf1000EASXFX1TXUniRemoteAread-onlycurrentFRM220-1000EAS/X RMON Fiber 1 Transceiver Unicast Packets.
1.3.6.1.4.1.4756.20.301.40.1.274Columnf1000EASXFX1TXPauseRemoteAread-onlycurrentFRM220-1000EAS/X RMON Fiber 1 Transceiver Pause Packets.
1.3.6.1.4.1.4756.20.301.40.1.275Columnf1000EASXFX1TXCollisionRemoteAread-onlycurrentFRM220-1000EAS/X RMON Fiber 1 Transceiver Collision Packets.
1.3.6.1.4.1.4756.20.301.40.1.276Columnf1000EASXFX10OctetsRemoteAread-onlycurrentFRM220-1000EAS/X RMON Fiber 1 Transceiver/Receiver 0~64 Octets.
1.3.6.1.4.1.4756.20.301.40.1.277Columnf1000EASXFX165OctetsRemoteAread-onlycurrentFRM220-1000EAS/X RMON Fiber 1 Transceiver/Receiver 65~127 Octets.
1.3.6.1.4.1.4756.20.301.40.1.278Columnf1000EASXFX1128OctetsRemoteAread-onlycurrentFRM220-1000EAS/X RMON Fiber 1 Transceiver/Receiver 128~255 Octets.
1.3.6.1.4.1.4756.20.301.40.1.279Columnf1000EASXFX1256OctetsRemoteAread-onlycurrentFRM220-1000EAS/X RMON Fiber 1 Transceiver/Receiver 256~511 Octets.
1.3.6.1.4.1.4756.20.301.40.1.280Columnf1000EASXFX1512OctetsRemoteAread-onlycurrentFRM220-1000EAS/X RMON Fiber 1 Transceiver/Receiver 512~1023 Octets.
1.3.6.1.4.1.4756.20.301.40.1.281Columnf1000EASXFX11024OctetsRemoteAread-onlycurrentFRM220-1000EAS/X RMON Fiber 1 Transceiver/Receiver 1024~Max Octets.
1.3.6.1.4.1.4756.20.301.40.1.282Columnf1000EASXFX2RXOctetsRemoteAread-onlycurrentFRM220-1000EAS/X RMON Fiber 2 Receiver Octets.
1.3.6.1.4.1.4756.20.301.40.1.283Columnf1000EASXFX2RXPacketRemoteAread-onlycurrentFRM220-1000EAS/X RMON Fiber 2 Receiver Packets.
1.3.6.1.4.1.4756.20.301.40.1.284Columnf1000EASXFX2RXBroadRemoteAread-onlycurrentFRM220-1000EAS/X RMON Fiber 2 Receiver Broadcast Packets.
1.3.6.1.4.1.4756.20.301.40.1.285Columnf1000EASXFX2RXMultiRemoteAread-onlycurrentFRM220-1000EAS/X RMON Fiber 2 Receiver Multicast Packets.
1.3.6.1.4.1.4756.20.301.40.1.286Columnf1000EASXFX2RXUniRemoteAread-onlycurrentFRM220-1000EAS/X RMON Fiber 2 Receiver Unicast Packets.
1.3.6.1.4.1.4756.20.301.40.1.287Columnf1000EASXFX2RXPauseRemoteAread-onlycurrentFRM220-1000EAS/X RMON Fiber 2 Receiver Pause Packets.
1.3.6.1.4.1.4756.20.301.40.1.288Columnf1000EASXFX2RXFCSERemoteAread-onlycurrentFRM220-1000EAS/X RMON Fiber 2 Receiver FCS Error Packets.
1.3.6.1.4.1.4756.20.301.40.1.289Columnf1000EASXFX2RXUnderRemoteAread-onlycurrentFRM220-1000EAS/X RMON Fiber 2 Receiver Under Packets.
1.3.6.1.4.1.4756.20.301.40.1.290Columnf1000EASXFX2RXOverRemoteAread-onlycurrentFRM220-1000EAS/X RMON Fiber 2 Receiver Over Packets.
1.3.6.1.4.1.4756.20.301.40.1.291Columnf1000EASXFX2RXJabberRemoteAread-onlycurrentFRM220-1000EAS/X RMON Fiber 2 Receiver Jabber Packets.
1.3.6.1.4.1.4756.20.301.40.1.292Columnf1000EASXFX2TXOctetsRemoteAread-onlycurrentFRM220-1000EAS/X RMON Fiber 2 Transceiver Octets.
1.3.6.1.4.1.4756.20.301.40.1.293Columnf1000EASXFX2TXPacketRemoteAread-onlycurrentFRM220-1000EAS/X RMON Fiber 2 Transceiver Packets.
1.3.6.1.4.1.4756.20.301.40.1.294Columnf1000EASXFX2TXBroadRemoteAread-onlycurrentFRM220-1000EAS/X RMON Fiber 2 Transceiver Broadcast Packets.
1.3.6.1.4.1.4756.20.301.40.1.295Columnf1000EASXFX2TXMultiRemoteAread-onlycurrentFRM220-1000EAS/X RMON Fiber 2 Transceiver Multicast Packets.
1.3.6.1.4.1.4756.20.301.40.1.296Columnf1000EASXFX2TXUniRemoteAread-onlycurrentFRM220-1000EAS/X RMON Fiber 2 Transceiver Unicast Packets.
1.3.6.1.4.1.4756.20.301.40.1.297Columnf1000EASXFX2TXPauseRemoteAread-onlycurrentFRM220-1000EAS/X RMON Fiber 2 Transceiver Pause Packets.
1.3.6.1.4.1.4756.20.301.40.1.298Columnf1000EASXFX2TXCollisionRemoteAread-onlycurrentFRM220-1000EAS/X RMON Fiber 2 Transceiver Collision Packets.
1.3.6.1.4.1.4756.20.301.40.1.299Columnf1000EASXFX20OctetsRemoteAread-onlycurrentFRM220-1000EAS/X RMON Fiber 2 Transceiver/Receiver 0~64 Octets.
1.3.6.1.4.1.4756.20.301.40.1.300Columnf1000EASXFX265OctetsRemoteAread-onlycurrentFRM220-1000EAS/X RMON Fiber 2 Transceiver/Receiver 65~127 Octets.
1.3.6.1.4.1.4756.20.301.40.1.301Columnf1000EASXFX2128OctetsRemoteAread-onlycurrentFRM220-1000EAS/X RMON Fiber 2 Transceiver/Receiver 128~255 Octets.
1.3.6.1.4.1.4756.20.301.40.1.302Columnf1000EASXFX2256OctetsRemoteAread-onlycurrentFRM220-1000EAS/X RMON Fiber 2 Transceiver/Receiver 256~511 Octets.
1.3.6.1.4.1.4756.20.301.40.1.303Columnf1000EASXFX2512OctetsRemoteAread-onlycurrentFRM220-1000EAS/X RMON Fiber 2 Transceiver/Receiver 512~1023 Octets.
1.3.6.1.4.1.4756.20.301.40.1.304Columnf1000EASXFX21024OctetsRemoteAread-onlycurrentFRM220-1000EAS/X RMON Fiber 2 Transceiver/Receiver 1024~Max Octets.
1.3.6.1.4.1.4756.20.301.40.1.305Columnf1000EASXUTP3RXOctetsRemoteAread-onlycurrentFRM220-1000EAS/X RMON UTP 3 Receiver Octets.
1.3.6.1.4.1.4756.20.301.40.1.306Columnf1000EASXUTP3RXPacketRemoteAread-onlycurrentFRM220-1000EAS/X RMON UTP 3 Receiver Packets.
1.3.6.1.4.1.4756.20.301.40.1.307Columnf1000EASXUTP3RXBroadRemoteAread-onlycurrentFRM220-1000EAS/X RMON UTP 3 Receiver Broadcast Packets.
1.3.6.1.4.1.4756.20.301.40.1.308Columnf1000EASXUTP3RXMultiRemoteAread-onlycurrentFRM220-1000EAS/X RMON UTP 3 Receiver Multicast Packets.
1.3.6.1.4.1.4756.20.301.40.1.309Columnf1000EASXUTP3RXUniRemoteAread-onlycurrentFRM220-1000EAS/X RMON UTP 3 Receiver Unicast Packets.
1.3.6.1.4.1.4756.20.301.40.1.310Columnf1000EASXUTP3RXPauseRemoteAread-onlycurrentFRM220-1000EAS/X RMON UTP 3 Receiver Pause Packets.
1.3.6.1.4.1.4756.20.301.40.1.311Columnf1000EASXUTP3RXFCSERemoteAread-onlycurrentFRM220-1000EAS/X RMON UTP 3 Receiver FCS Error Packets.
1.3.6.1.4.1.4756.20.301.40.1.312Columnf1000EASXUTP3RXUnderRemoteAread-onlycurrentFRM220-1000EAS/X RMON UTP 3 Receiver Under Packets.
1.3.6.1.4.1.4756.20.301.40.1.313Columnf1000EASXUTP3RXOverRemoteAread-onlycurrentFRM220-1000EAS/X RMON UTP 3 Receiver Over Packets.
1.3.6.1.4.1.4756.20.301.40.1.314Columnf1000EASXUTP3RXJabberRemoteAread-onlycurrentFRM220-1000EAS/X RMON UTP 3 Receiver Jabber Packets.
1.3.6.1.4.1.4756.20.301.40.1.315Columnf1000EASXUTP3TXOctetsRemoteAread-onlycurrentFRM220-1000EAS/X RMON UTP 3 Transceiver Octets.
1.3.6.1.4.1.4756.20.301.40.1.316Columnf1000EASXUTP3TXPacketRemoteAread-onlycurrentFRM220-1000EAS/X RMON UTP 3 Transceiver Packets.
1.3.6.1.4.1.4756.20.301.40.1.317Columnf1000EASXUTP3TXBroadRemoteAread-onlycurrentFRM220-1000EAS/X RMON UTP 3 Transceiver Broadcast Packets.
1.3.6.1.4.1.4756.20.301.40.1.318Columnf1000EASXUTP3TXMultiRemoteAread-onlycurrentFRM220-1000EAS/X RMON UTP 3 Transceiver Multicast Packets.
1.3.6.1.4.1.4756.20.301.40.1.319Columnf1000EASXUTP3TXUniRemoteAread-onlycurrentFRM220-1000EAS/X RMON UTP 3 Transceiver Unicast Packets.
1.3.6.1.4.1.4756.20.301.40.1.320Columnf1000EASXUTP3TXPauseRemoteAread-onlycurrentFRM220-1000EAS/X RMON UTP 3 Transceiver Pause Packets.
1.3.6.1.4.1.4756.20.301.40.1.321Columnf1000EASXUTP3TXCollisionRemoteAread-onlycurrentFRM220-1000EAS/X RMON UTP 3 Transceiver Collision Packets.
1.3.6.1.4.1.4756.20.301.40.1.322Columnf1000EASXUTP30OctetsRemoteAread-onlycurrentFRM220-1000EAS/X RMON UTP 3 Transceiver/Receiver 0~64 Octets.
1.3.6.1.4.1.4756.20.301.40.1.323Columnf1000EASXUTP365OctetsRemoteAread-onlycurrentFRM220-1000EAS/X RMON UTP 3 Transceiver/Receiver 65~127 Octets.
1.3.6.1.4.1.4756.20.301.40.1.324Columnf1000EASXUTP3128OctetsRemoteAread-onlycurrentFRM220-1000EAS/X RMON UTP 3 Transceiver/Receiver 128~255 Octets.
1.3.6.1.4.1.4756.20.301.40.1.325Columnf1000EASXUTP3256OctetsRemoteAread-onlycurrentFRM220-1000EAS/X RMON UTP 3 Transceiver/Receiver 256~511 Octets.
1.3.6.1.4.1.4756.20.301.40.1.326Columnf1000EASXUTP3512OctetsRemoteAread-onlycurrentFRM220-1000EAS/X RMON UTP 3 Transceiver/Receiver 512~1023 Octets.
1.3.6.1.4.1.4756.20.301.40.1.327Columnf1000EASXUTP31024OctetsRemoteAread-onlycurrentFRM220-1000EAS/X RMON UTP 3 Transceiver/Receiver 1024~Max Octets.
1.3.6.1.4.1.4756.20.301.40.1.328Columnf1000EASXUTP4RXOctetsRemoteAread-onlycurrentFRM220-1000EAS/X RMON UTP 4 Receiver Octets.
1.3.6.1.4.1.4756.20.301.40.1.329Columnf1000EASXUTP4RXPacketRemoteAread-onlycurrentFRM220-1000EAS/X RMON UTP 4 Receiver Packets.
1.3.6.1.4.1.4756.20.301.40.1.330Columnf1000EASXUTP4RXBroadRemoteAread-onlycurrentFRM220-1000EAS/X RMON UTP 4 Receiver Broadcast Packets.
1.3.6.1.4.1.4756.20.301.40.1.331Columnf1000EASXUTP4RXMultiRemoteAread-onlycurrentFRM220-1000EAS/X RMON UTP 4 Receiver Multicast Packets.
1.3.6.1.4.1.4756.20.301.40.1.332Columnf1000EASXUTP4RXUniRemoteAread-onlycurrentFRM220-1000EAS/X RMON UTP 4 Receiver Unicast Packets.
1.3.6.1.4.1.4756.20.301.40.1.333Columnf1000EASXUTP4RXPauseRemoteAread-onlycurrentFRM220-1000EAS/X RMON UTP 4 Receiver Pause Packets.
1.3.6.1.4.1.4756.20.301.40.1.334Columnf1000EASXUTP4RXFCSERemoteAread-onlycurrentFRM220-1000EAS/X RMON UTP 4 Receiver FCS Error Packets.
1.3.6.1.4.1.4756.20.301.40.1.335Columnf1000EASXUTP4RXUnderRemoteAread-onlycurrentFRM220-1000EAS/X RMON UTP 4 Receiver Under Packets.
1.3.6.1.4.1.4756.20.301.40.1.336Columnf1000EASXUTP4RXOverRemoteAread-onlycurrentFRM220-1000EAS/X RMON UTP 4 Receiver Over Packets.
1.3.6.1.4.1.4756.20.301.40.1.337Columnf1000EASXUTP4RXJabberRemoteAread-onlycurrentFRM220-1000EAS/X RMON UTP 4 Receiver Jabber Packets.
1.3.6.1.4.1.4756.20.301.40.1.338Columnf1000EASXUTP4TXOctetsRemoteAread-onlycurrentFRM220-1000EAS/X RMON UTP 4 Transceiver Octets.
1.3.6.1.4.1.4756.20.301.40.1.339Columnf1000EASXUTP4TXPacketRemoteAread-onlycurrentFRM220-1000EAS/X RMON UTP 4 Transceiver Packets.
1.3.6.1.4.1.4756.20.301.40.1.340Columnf1000EASXUTP4TXBroadRemoteAread-onlycurrentFRM220-1000EAS/X RMON UTP 4 Transceiver Broadcast Packets.
1.3.6.1.4.1.4756.20.301.40.1.341Columnf1000EASXUTP4TXMultiRemoteAread-onlycurrentFRM220-1000EAS/X RMON UTP 4 Transceiver Multicast Packets.
1.3.6.1.4.1.4756.20.301.40.1.342Columnf1000EASXUTP4TXUniRemoteAread-onlycurrentFRM220-1000EAS/X RMON UTP 4 Transceiver Unicast Packets.
1.3.6.1.4.1.4756.20.301.40.1.343Columnf1000EASXUTP4TXPauseRemoteAread-onlycurrentFRM220-1000EAS/X RMON UTP 4 Transceiver Pause Packets.
1.3.6.1.4.1.4756.20.301.40.1.344Columnf1000EASXUTP4TXCollisionRemoteAread-onlycurrentFRM220-1000EAS/X RMON UTP 4 Transceiver Collision Packets.
1.3.6.1.4.1.4756.20.301.40.1.345Columnf1000EASXUTP40OctetsRemoteAread-onlycurrentFRM220-1000EAS/X RMON UTP 4 Transceiver/Receiver 0~64 Octets.
1.3.6.1.4.1.4756.20.301.40.1.346Columnf1000EASXUTP465OctetsRemoteAread-onlycurrentFRM220-1000EAS/X RMON UTP 4 Transceiver/Receiver 65~127 Octets.
1.3.6.1.4.1.4756.20.301.40.1.347Columnf1000EASXUTP4128OctetsRemoteAread-onlycurrentFRM220-1000EAS/X RMON UTP 4 Transceiver/Receiver 128~255 Octets.
1.3.6.1.4.1.4756.20.301.40.1.348Columnf1000EASXUTP4256OctetsRemoteAread-onlycurrentFRM220-1000EAS/X RMON UTP 4 Transceiver/Receiver 256~511 Octets.
1.3.6.1.4.1.4756.20.301.40.1.349Columnf1000EASXUTP4512OctetsRemoteAread-onlycurrentFRM220-1000EAS/X RMON UTP 4 Transceiver/Receiver 512~1023 Octets.
1.3.6.1.4.1.4756.20.301.40.1.350Columnf1000EASXUTP41024OctetsRemoteAread-onlycurrentFRM220-1000EAS/X RMON UTP 4 Transceiver/Receiver 1024~Max Octets.
1.3.6.1.4.1.4756.20.302Nodef1000EASXRemoteBCards
1.3.6.1.4.1.4756.20.302.40Tablef1000EASXRemoteBTablenot-accessiblecurrentA list of RemoteB 1000EAS/X card entries.
1.3.6.1.4.1.4756.20.302.40.1Rowf1000EASXRemoteBEntrynot-accessiblecurrentAn entry containing management information applicable to a particular RemoteB f1000EASX card.
1.3.6.1.4.1.4756.20.302.40.1.1Columnf1000EASXChassisIndexRemoteBread-onlycurrentA unique value for each chassis ID. For CH20, it is the chassis ID. For CH08, it is always 0.
1.3.6.1.4.1.4756.20.302.40.1.2Columnf1000EASXSlotIndexRemoteBread-onlycurrentA unique value for each RemoteB card. It is the slot location number.
1.3.6.1.4.1.4756.20.302.40.1.3Columnf1000EASXCardHWVerRemoteBread-onlycurrentRemoteB device card hardware version x.xxx
1.3.6.1.4.1.4756.20.302.40.1.4Columnf1000EASXCardFWVerRemoteBread-onlycurrentRemoteB device card firmware version x.xxx
1.3.6.1.4.1.4756.20.302.40.1.5Columnf1000EASXCardCPLDVerRemoteBread-onlycurrentRemoteB device card CPLD version x.xxx
1.3.6.1.4.1.4756.20.302.40.1.6Columnf1000EASXCardFPGAVerRemoteBread-onlycurrentRemoteB device card FPGA version x.xxx
1.3.6.1.4.1.4756.20.302.40.1.7Columnf1000EASXModelRemoteBread-onlycurrentRemoteB 1000EAS/X Serial Type
1.3.6.1.4.1.4756.20.302.40.1.8Columnf1000EASXFiber1LinkRemoteBread-onlycurrentRemoteB device card fiber port 1 link status: 0:Down 1:Up
1.3.6.1.4.1.4756.20.302.40.1.9Columnf1000EASXFiber1OAMLoopedRemoteBread-onlycurrentRemoteB device card fiber port 1 OAM looped: 0:Off 1:on
1.3.6.1.4.1.4756.20.302.40.1.10Columnf1000EASXFiber1LBTestRemoteBread-writecurrentForce remote device card to do fiber port 1 LoopBack testing: 0:Off 1:Action
1.3.6.1.4.1.4756.20.302.40.1.11Columnf1000EASXFiber1OAMRLBStatusRemoteBread-onlycurrentRemote device card fiber port 1 LoopBack testing status: 0:Off 1:Ok 2:Fail
1.3.6.1.4.1.4756.20.302.40.1.12Columnf1000EASXFiber1RemoPwrAbRemoteBread-onlycurrentRemoteB device card fiber port 1 Remote Power status: 0:Abnormal 1:OK 2:None
1.3.6.1.4.1.4756.20.302.40.1.13Columnf1000EASXFiber1IngressRateRemoteBread-writecurrentRemoteB device card fiber 1 Ingress Rate Limit: 0 = Unlimit input format: 64k(K),100m(M),100 If doesn't input the unit, the default was Mega. Limite Rate : 64K…
1.3.6.1.4.1.4756.20.302.40.1.14Columnf1000EASXFiber1EgressRateRemoteBread-writecurrentRemoteB device card fiber 1 Egress Rate Limit: 0 = Unlimit input format: 64k(K),100m(M),100 If doesn't input the unit, the default was Mega. Limite Rate : 64K …
1.3.6.1.4.1.4756.20.302.40.1.15Columnf1000EASXFiber2LinkRemoteBread-onlycurrentRemoteB device card fiber port 2 link status: 0:Down 1:Up
1.3.6.1.4.1.4756.20.302.40.1.16Columnf1000EASXFiber2OAMLoopedRemoteBread-onlycurrentRemoteB device card fiber port 2 OAM looped: 0:Off 1:on
1.3.6.1.4.1.4756.20.302.40.1.17Columnf1000EASXFiber2LBTestRemoteBread-writecurrentForce remote device card to do fiber port 2 LoopBack testing: 0:Off 1:Action
1.3.6.1.4.1.4756.20.302.40.1.18Columnf1000EASXFiber2OAMRLBStatusRemoteBread-onlycurrentRemote device card fiber port 1 LoopBack testing status: 0:Off 1:Ok 2:Fail
1.3.6.1.4.1.4756.20.302.40.1.19Columnf1000EASXFiber2RemoPwrAbRemoteBread-onlycurrentRemoteB device card fiber port 2 Remote Power status: 0:Abnormal 1:OK 2:None
1.3.6.1.4.1.4756.20.302.40.1.20Columnf1000EASXFiber2IngressRateRemoteBread-writecurrentRemoteB device card fiber 2 Ingress Rate Limit: 0 = Unlimit input format: 64k(K),100m(M),100 If doesn't input the unit, the default was Mega. Limite Rate : 64K…
1.3.6.1.4.1.4756.20.302.40.1.21Columnf1000EASXFiber2EgressRateRemoteBread-writecurrentRemoteB device card fiber 2 Egress Rate Limit: 0 = Unlimit input format: 64k(K),100m(M),100 If doesn't input the unit, the default was Mega. Limite Rate : 64K …
1.3.6.1.4.1.4756.20.302.40.1.22Columnf1000EASXUtp3LinkRemoteBread-onlycurrentRemoteB device card UTP port 3 link status: 0:Down 1:Up
1.3.6.1.4.1.4756.20.302.40.1.23Columnf1000EASXUtp3NegoRemoteBread-writecurrentRemoteB device card UTP port 3 negotiation status: 0:Manual 1:Auto
1.3.6.1.4.1.4756.20.302.40.1.24Columnf1000EASXUtp3SpeedRemoteBread-writecurrentRemoteB device card UTP port 3 speed setting: 0:10 Base-T 1:100 Base-TX 2:1000 Base-TX
1.3.6.1.4.1.4756.20.302.40.1.25Columnf1000EASXUtp3DuplexRemoteBread-writecurrentRemoteB device card UTP port 3 duplex setting: 0:Half duplex mode 1:Full duplex mode
1.3.6.1.4.1.4756.20.302.40.1.26Columnf1000EASXUtp3SpeedStatusRemoteBread-onlycurrentRemoteB device card UTP port 3 speed status: 0:10 Base-T 1:100 Base-TX 2:1000 Base-TX
1.3.6.1.4.1.4756.20.302.40.1.27Columnf1000EASXUtp3DuplexStatusRemoteBread-onlycurrentRemoteB device card UTP port 3 duplex status: 0:Half duplex mode 1:Full duplex mode
1.3.6.1.4.1.4756.20.302.40.1.28Columnf1000EASXUtp3IngressRateRemoteBread-writecurrentRemoteB device card utp 3 Ingress Rate Limit: 0 = Unlimit input format: 64k(K),100m(M),100 If doesn't input the unit, the default was Mega. Limite Rate : 64K ~…
1.3.6.1.4.1.4756.20.302.40.1.29Columnf1000EASXUtp3EgressRateRemoteBread-writecurrentRemoteB device card utp 3 Egress Rate Limit: 0 = Unlimit input format: 64k(K),100m(M),100 If doesn't input the unit, the default was Mega. Limite Rate : 64K ~ …
1.3.6.1.4.1.4756.20.302.40.1.30Columnf1000EASXUtp4LinkRemoteBread-onlycurrentRemoteB device card UTP port 4 link status: 0:Down 1:Up
1.3.6.1.4.1.4756.20.302.40.1.31Columnf1000EASXUtp4NegoRemoteBread-writecurrentRemoteB device card UTP port 4 negotiation status: 0:Manual 1:Auto
1.3.6.1.4.1.4756.20.302.40.1.32Columnf1000EASXUtp4SpeedRemoteBread-writecurrentRemoteB device card UTP port 4 speed setting: 0:10 Base-T 1:100 Base-TX 2:1000 Base-TX
1.3.6.1.4.1.4756.20.302.40.1.33Columnf1000EASXUtp4DuplexRemoteBread-writecurrentRemoteB device card UTP port 4 duplex setting: 0:Half duplex mode 1:Full duplex mode
1.3.6.1.4.1.4756.20.302.40.1.34Columnf1000EASXUtp4SpeedStatusRemoteBread-onlycurrentRemoteB device card UTP port 4 speed status: 0:10 Base-T 1:100 Base-TX 2:1000 Base-TX
1.3.6.1.4.1.4756.20.302.40.1.35Columnf1000EASXUtp4DuplexStatusRemoteBread-onlycurrentRemoteB device card UTP port 4 duplex status: 0:Half duplex mode 1:Full duplex mode
1.3.6.1.4.1.4756.20.302.40.1.36Columnf1000EASXUtp4IngressRateRemoteBread-writecurrentRemoteB device card utp 4 Ingress Rate Limit: 0 = Unlimit input format: 64k(K),100m(M),100 If doesn't input the unit, the default was Mega. Limite Rate : 64K ~…
1.3.6.1.4.1.4756.20.302.40.1.37Columnf1000EASXUtp4EgressRateRemoteBread-writecurrentRemoteB device card utp 4 Egress Rate Limit: 0 = Unlimit input format: 64k(K),100m(M),100 If doesn't input the unit, the default was Mega. Limite Rate : 64K ~ …
1.3.6.1.4.1.4756.20.302.40.1.38Columnf1000EASXDeviceResetRemoteBread-writecurrentForce RemoteB device card to reset mode: 0:Off 1:Action
1.3.6.1.4.1.4756.20.302.40.1.39Columnf1000EASXUtp3ActiveRemoteBread-writecurrentRemoteB device UTP port 3 active mode: 0:Disable 1:Enable
1.3.6.1.4.1.4756.20.302.40.1.40Columnf1000EASXUtp4ActiveRemoteBread-writecurrentRemoteB device UTP port 4 active mode: 0:Disable 1:Enable
1.3.6.1.4.1.4756.20.302.40.1.41Columnf1000EASXOamChAModeRemoteBread-writecurrentRemoteB device OAM Channel A mode: 0:Disable 1:passive 2:Active
1.3.6.1.4.1.4756.20.302.40.1.42Columnf1000EASXOamChBModeRemoteBread-writecurrentRemoteB device OAM Channel B mode: 0:Disable 1:passive 2:Active
1.3.6.1.4.1.4756.20.302.40.1.43Columnf1000EASXOamMaxPDUsRemoteBread-writecurrentRemoteB device OAM max OAMPDU size: 60-1518 Octets
1.3.6.1.4.1.4756.20.302.40.1.44Columnf1000EASXFiber1AlsRemoteBread-writecurrentRemoteB device card port 1 Auto Laser Shutdown mode: 0:Disable 1:Enable
1.3.6.1.4.1.4756.20.302.40.1.45Columnf1000EASXFiber2AlsRemoteBread-writecurrentRemoteB device card port 2 Auto Laser Shutdown mode: 0:Disable 1:Enable
1.3.6.1.4.1.4756.20.302.40.1.46Columnf1000EASXPauseFrameRemoteBread-writecurrentRemoteB device card pause frame mode: 0:Disable 1:Enable
1.3.6.1.4.1.4756.20.302.40.1.47Columnf1000EASXFHRModeRemoteBread-writecurrentRemoteB device card FHR Mode: 0:Disable 1:Enable
1.3.6.1.4.1.4756.20.302.40.1.48Columnf1000EASXFiber1LLFDepLogiRemoteBread-writecurrentRemoteB device card port 1 Link Loss Forwarding depends boolean logic: 0:and 1:or
1.3.6.1.4.1.4756.20.302.40.1.49Columnf1000EASXFiber1LLFDepPort2RemoteBread-writecurrentRemoteB device card port 1 Link Loss Forwarding depends on port 2 Fiber Rx link: 0:don't care 1:selected
1.3.6.1.4.1.4756.20.302.40.1.50Columnf1000EASXFiber1LLFDepPort3RemoteBread-writecurrentRemoteB device card port 1 Link Loss Forwarding depends on port 3 Ethernet Rx link: 0:don't care 1:selected
1.3.6.1.4.1.4756.20.302.40.1.51Columnf1000EASXFiber1LLFDepPort4RemoteBread-writecurrentRemoteB device card port 1 Link Loss Forwarding depends on port 4 Ethernet Rx link: 0:don't care 1:selected
1.3.6.1.4.1.4756.20.302.40.1.52Columnf1000EASXFiber2LLFDepLogiRemoteBread-writecurrentRemoteB device card port 2 Link Loss Forwarding depends boolean logic: 0:and 1:or
1.3.6.1.4.1.4756.20.302.40.1.53Columnf1000EASXFiber2LLFDepPort1RemoteBread-writecurrentRemoteB device card port 2 Link Loss Forwarding depends on port 1 Fiber Rx link: 0:don't care 1:selected
1.3.6.1.4.1.4756.20.302.40.1.54Columnf1000EASXFiber2LLFDepPort3RemoteBread-writecurrentRemoteB device card port 2 Link Loss Forwarding depends on port 3 Ethernet Rx link: 0:don't care 1:selected
1.3.6.1.4.1.4756.20.302.40.1.55Columnf1000EASXFiber2LLFDepPort4RemoteBread-writecurrentRemoteB device card port 2 Link Loss Forwarding depends on port 4 Ethernet Rx link: 0:don't care 1:selected
1.3.6.1.4.1.4756.20.302.40.1.56Columnf1000EASXUtp3LLFDepLogiRemoteBread-writecurrentRemoteB device card port 3 Link Loss Forwarding depends boolean logic: 0:and 1:or
1.3.6.1.4.1.4756.20.302.40.1.57Columnf1000EASXUtp3LLFDepPort1RemoteBread-writecurrentRemoteB device card port 3 Link Loss Forwarding depends on port 1 Fiber Rx link: 0:don't care 1:selected
1.3.6.1.4.1.4756.20.302.40.1.58Columnf1000EASXUtp3LLFDepPort2RemoteBread-writecurrentRemoteB device card port 3 Link Loss Forwarding depends on port 2 Fiber Rx link: 0:don't care 1:selected
1.3.6.1.4.1.4756.20.302.40.1.59Columnf1000EASXUtp4LLFDepLogiRemoteBread-writecurrentRemoteB device card port 4 Link Loss Forwarding depends boolean logic: 0:and 1:or
1.3.6.1.4.1.4756.20.302.40.1.60Columnf1000EASXUtp4LLFDepPort1RemoteBread-writecurrentRemoteB device card port 4 Link Loss Forwarding depends on port 1 Fiber Rx link: 0:don't care 1:selected
1.3.6.1.4.1.4756.20.302.40.1.61Columnf1000EASXUtp4LLFDepPort2RemoteBread-writecurrentRemoteB device card port 4 Link Loss Forwarding depends on port 2 Fiber Rx link: 0:don't care 1:selected
1.3.6.1.4.1.4756.20.302.40.1.62Columnf1000EASXAdvanceFunsRemoteBread-writecurrentRemoteB device card Switch functions mode: 0:Normal 1:Port 1 and Port 2 Trunk Bandwidth 2G 2:Port 1 to Port 2 Mirror 4:port 1 and port 2 Redundancy 5:Static 80…
1.3.6.1.4.1.4756.20.302.40.1.63Columnf1000EASXFiber1InfoROM1RemoteBread-onlycurrentRemoteB device card port 1 INFORemoteOM information 1 valid: 0:Invalid 1:Valid
1.3.6.1.4.1.4756.20.302.40.1.64Columnf1000EASXFiber1InfoROM2RemoteBread-onlycurrentRemoteB device card port 1 INFORemoteOM information 2 valid: 0:Invalid 1:Valid(replacing D/D function
1.3.6.1.4.1.4756.20.302.40.1.65Columnf1000EASXFiber2InfoROM1RemoteBread-onlycurrentRemoteB device card port 2 INFORemoteOM information 1 valid: 0:Invalid 1:Valid
1.3.6.1.4.1.4756.20.302.40.1.66Columnf1000EASXFiber2InfoROM2RemoteBread-onlycurrentRemoteB device card port 2 INFORemoteOM information 2 valid: 0:Invalid 1:Valid(replacing D/D function)
1.3.6.1.4.1.4756.20.302.40.1.67Columnf1000EASXFiber1InfoSN1RemoteBread-onlycurrentRemoteB device card port 1 INFORemoteOM S/N 1
1.3.6.1.4.1.4756.20.302.40.1.68Columnf1000EASXFiber1InfoSN2RemoteBread-onlycurrentRemoteB device card port 1 INFORemoteOM S/N 2
1.3.6.1.4.1.4756.20.302.40.1.69Columnf1000EASXFiber2InfoSN1RemoteBread-onlycurrentRemoteB device card port 2 INFORemoteOM S/N 1
1.3.6.1.4.1.4756.20.302.40.1.70Columnf1000EASXFiber2InfoSN2RemoteBread-onlycurrentRemoteB device card port 2 INFORemoteOM S/N 2
1.3.6.1.4.1.4756.20.302.40.1.71Columnf1000EASXFiber1DDRemoteBread-onlycurrentRemoteB device card fiber port 1 Digital Diagnostic function: 0:No 1:Yes
1.3.6.1.4.1.4756.20.302.40.1.72Columnf1000EASXFiber1DDVendorRemoteBread-onlycurrentRemoteB device card fiber port 1 D/D information: Vendor name
1.3.6.1.4.1.4756.20.302.40.1.73Columnf1000EASXFiber1DDPartNoRemoteBread-onlycurrentRemoteB device card fiber port 1 D/D information: Vendor part number
1.3.6.1.4.1.4756.20.302.40.1.74Columnf1000EASXFiber1DDVendorSNRemoteBread-onlycurrentRemoteB device card fiber port 1 D/D information: Vendor Serial Number
1.3.6.1.4.1.4756.20.302.40.1.75Columnf1000EASXFiber1DDFiberTypeRemoteBread-onlycurrentRemoteB device card fiber port 1 D/D information: Fiber Type
1.3.6.1.4.1.4756.20.302.40.1.76Columnf1000EASXFiber1DDWaveLenRemoteBread-onlycurrentRemoteB device card fiber port 1 D/D information: Wave length
1.3.6.1.4.1.4756.20.302.40.1.77Columnf1000EASXFiber1DDWaveLen2RemoteBread-onlycurrentRemoteB device card fiber port 1 D/D information: Wave length 2
1.3.6.1.4.1.4756.20.302.40.1.78Columnf1000EASXFiber1DDLinkLenRemoteBread-onlycurrentRemoteB device card fiber port 1 D/D information: Link length
1.3.6.1.4.1.4756.20.302.40.1.79Columnf1000EASXFiber1DDLenUnitRemoteBread-onlycurrentRemoteB device card fiber port 1 D/D information: Length Unit
1.3.6.1.4.1.4756.20.302.40.1.80Columnf1000EASXFiber1DDStatusRemoteBread-onlycurrentRemoteB device card fiber port 1 D/D information: Status Support
1.3.6.1.4.1.4756.20.302.40.1.81Columnf1000EASXFiber1DDRxSensRemoteBread-onlycurrentRemoteB device card fiber port 1 D/D information: Rx Sensitivity
1.3.6.1.4.1.4756.20.302.40.1.82Columnf1000EASXFiber1DDTxPWRRemoteBread-onlycurrentRemoteB device card fiber port 1 D/D information: Tx power
1.3.6.1.4.1.4756.20.302.40.1.83Columnf1000EASXFiber1DDRxPWRRemoteBread-onlycurrentRemoteB device card fiber port 1 D/D information: Rx power
1.3.6.1.4.1.4756.20.302.40.1.84Columnf1000EASXFiber1DDTempRemoteBread-onlycurrentRemoteB device card fiber port 1 D/D information: Temperature in degree C
1.3.6.1.4.1.4756.20.302.40.1.85Columnf1000EASXFiber1DDPWRMarginRemoteBread-onlycurrentRemoteB device card fiber port 1 D/D information: Power margin
1.3.6.1.4.1.4756.20.302.40.1.86Columnf1000EASXFiber1DDPWRLossRemoteBread-onlycurrentRemoteB device card fiber port 1 D/D information: Power loss
1.3.6.1.4.1.4756.20.302.40.1.87Columnf1000EASXFiber2DDRemoteBread-onlycurrentRemoteB device card fiber port 2 Digital Diagnostic function: 0:No 1:Yes
1.3.6.1.4.1.4756.20.302.40.1.88Columnf1000EASXFiber2DDVendorRemoteBread-onlycurrentRemoteB device card fiber port 2 D/D information: Vendor name
1.3.6.1.4.1.4756.20.302.40.1.89Columnf1000EASXFiber2DDPartNoRemoteBread-onlycurrentRemoteB device card fiber port 2 D/D information: Vendor part number
1.3.6.1.4.1.4756.20.302.40.1.90Columnf1000EASXFiber2DDVendorSNRemoteBread-onlycurrentRemoteB device card fiber port 2 D/D information: Vendor Serial Number
1.3.6.1.4.1.4756.20.302.40.1.91Columnf1000EASXFiber2DDFiberTypeRemoteBread-onlycurrentRemoteB device card fiber port 2 D/D information: Fiber Type
1.3.6.1.4.1.4756.20.302.40.1.92Columnf1000EASXFiber2DDWaveLenRemoteBread-onlycurrentRemoteB device card fiber port 2 D/D information: Wave length
1.3.6.1.4.1.4756.20.302.40.1.93Columnf1000EASXFiber2DDWaveLen2RemoteBread-onlycurrentRemoteB device card fiber port 2 D/D information: Wave length 2
1.3.6.1.4.1.4756.20.302.40.1.94Columnf1000EASXFiber2DDLinkLenRemoteBread-onlycurrentRemoteB device card fiber port 2 D/D information: Link length
1.3.6.1.4.1.4756.20.302.40.1.95Columnf1000EASXFiber2DDLenUnitRemoteBread-onlycurrentRemoteB device card fiber port 2 D/D information: Length Unit
1.3.6.1.4.1.4756.20.302.40.1.96Columnf1000EASXFiber2DDStatusRemoteBread-onlycurrentRemoteB device card fiber port 2 D/D information: Status Support
1.3.6.1.4.1.4756.20.302.40.1.97Columnf1000EASXFiber2DDRxSensRemoteBread-onlycurrentRemoteB device card fiber port 2 D/D information: Rx Sensitivity
1.3.6.1.4.1.4756.20.302.40.1.98Columnf1000EASXFiber2DDTxPWRRemoteBread-onlycurrentRemoteB device card fiber port 2 D/D information: Tx power
1.3.6.1.4.1.4756.20.302.40.1.99Columnf1000EASXFiber2DDRxPWRRemoteBread-onlycurrentRemoteB device card fiber port 2 D/D information: Rx power
1.3.6.1.4.1.4756.20.302.40.1.100Columnf1000EASXFiber2DDTempRemoteBread-onlycurrentRemoteB device card fiber port 2 D/D information: Temperature in degree C
1.3.6.1.4.1.4756.20.302.40.1.101Columnf1000EASXFiber2DDPWRMarginRemoteBread-onlycurrentRemoteB device card fiber port 2 D/D information: Power margin
1.3.6.1.4.1.4756.20.302.40.1.102Columnf1000EASXFiber2DDPWRLossRemoteBread-onlycurrentRemoteB device card fiber port 2 D/D information: Power loss
1.3.6.1.4.1.4756.20.302.40.1.103Columnf1000EASXClrRMONCntsRemoteBread-writecurrentClear RemoteB device card RMON IN/OUT counters: 0:No action 1:Action
1.3.6.1.4.1.4756.20.302.40.1.104Columnf1000EASXFiber1RMONInRemoteBread-onlycurrentRemoteB device card port 1 RMON IN counter.
1.3.6.1.4.1.4756.20.302.40.1.105Columnf1000EASXFiber1RMONOutRemoteBread-onlycurrentRemoteB device card port 1 RMON OUT counter.
1.3.6.1.4.1.4756.20.302.40.1.106Columnf1000EASXFiber2RMONInRemoteBread-onlycurrentRemoteB device card port 2 RMON IN counter.
1.3.6.1.4.1.4756.20.302.40.1.107Columnf1000EASXFiber2RMONOutRemoteBread-onlycurrentRemoteB device card port 2 RMON OUT counter.
1.3.6.1.4.1.4756.20.302.40.1.108Columnf1000EASXUtp3RMONInRemoteBread-onlycurrentRemoteB device card port 3 RMON IN counter.
1.3.6.1.4.1.4756.20.302.40.1.109Columnf1000EASXUtp3RMONOutRemoteBread-onlycurrentRemoteB device card port 3 RMON OUT counter.
1.3.6.1.4.1.4756.20.302.40.1.110Columnf1000EASXUtp4RMONInRemoteBread-onlycurrentRemoteB device card port 4 RMON IN counter.
1.3.6.1.4.1.4756.20.302.40.1.111Columnf1000EASXUtp4RMONOutRemoteBread-onlycurrentRemoteB device card port 4 RMON OUT counter.
1.3.6.1.4.1.4756.20.302.40.1.112Columnf1000EASXClrOAMCntsRemoteBread-writecurrentClear RemoteB device card OAM counters: 0:No action 1:Action
1.3.6.1.4.1.4756.20.302.40.1.113Columnf1000EASXIpModeRemoteBread-writecurrentOn Rack Ip Mode: 0:Enable 1:Disable
1.3.6.1.4.1.4756.20.302.40.1.114Columnf1000EASXOamChATxRemoteBread-onlycurrentRemoteB device OAM Channel A TX OAMPDU frame count
1.3.6.1.4.1.4756.20.302.40.1.115Columnf1000EASXOamChARxRemoteBread-onlycurrentRemoteB device OAM Channel A RX OAMPDU frame count
1.3.6.1.4.1.4756.20.302.40.1.116Columnf1000EASXOamInfoChATxRemoteBread-onlycurrentRemoteB device OAM Channel A TX Information OAMPDU frame count
1.3.6.1.4.1.4756.20.302.40.1.117Columnf1000EASXOamInfoChARxRemoteBread-onlycurrentRemoteB device OAM Channel A RX Information OAMPDU frame count
1.3.6.1.4.1.4756.20.302.40.1.118Columnf1000EASXOamEventChATxRemoteBread-onlycurrentRemoteB device OAM Channel A TX Event OAMPDU frame count
1.3.6.1.4.1.4756.20.302.40.1.119Columnf1000EASXOamUniEvtChARxRemoteBread-onlycurrentRemoteB device OAM Channel A RX Unique Event OAMPDU frame count
1.3.6.1.4.1.4756.20.302.40.1.120Columnf1000EASXOamDupEvtChARxRemoteBread-onlycurrentRemoteB device OAM Channel A RX Duplicate Event OAMPDU frame count
1.3.6.1.4.1.4756.20.302.40.1.121Columnf1000EASXOamLbChATxRemoteBread-onlycurrentRemoteB device OAM Channel A TX Loopback Control OAMPDU frame count
1.3.6.1.4.1.4756.20.302.40.1.122Columnf1000EASXOamLbChARxRemoteBread-onlycurrentRemoteB device OAM Channel A RX Loopback Control OAMPDU frame count
1.3.6.1.4.1.4756.20.302.40.1.123Columnf1000EASXOamVarReqChATxRemoteBread-onlycurrentRemoteB device OAM Channel A TX Variable Request OAMPDU frame count
1.3.6.1.4.1.4756.20.302.40.1.124Columnf1000EASXOamVarReqChARxRemoteBread-onlycurrentRemoteB device OAM Channel A RX Variable Request OAMPDU frame count
1.3.6.1.4.1.4756.20.302.40.1.125Columnf1000EASXOamVarRspChATxRemoteBread-onlycurrentRemoteB device OAM Channel A TX Variable Response OAMPDU frame count
1.3.6.1.4.1.4756.20.302.40.1.126Columnf1000EASXOamVarRspChARxRemoteBread-onlycurrentRemoteB device OAM Channel A RX Variable Response OAMPDU frame count
1.3.6.1.4.1.4756.20.302.40.1.127Columnf1000EASXOamOuiChATxRemoteBread-onlycurrentRemoteB device OAM Channel A TX OUI OAMPDU frame count
1.3.6.1.4.1.4756.20.302.40.1.128Columnf1000EASXOamOuiChARxRemoteBread-onlycurrentRemoteB device OAM Channel A RX OUI OAMPDU frame count
1.3.6.1.4.1.4756.20.302.40.1.129Columnf1000EASXOamUnknowChARxRemoteBread-onlycurrentRemoteB device OAM Channel A RX Unsupported OAMPDU frame count
1.3.6.1.4.1.4756.20.302.40.1.130Columnf1000EASXOamChBTxRemoteBread-onlycurrentRemoteB device OAM Channel B TX OAMPDU frame count
1.3.6.1.4.1.4756.20.302.40.1.131Columnf1000EASXOamChBRxRemoteBread-onlycurrentRemoteB device OAM Channel B RX OAMPDU frame count
1.3.6.1.4.1.4756.20.302.40.1.132Columnf1000EASXOamInfoChBTxRemoteBread-onlycurrentRemoteB device OAM Channel B TX Information OAMPDU frame count
1.3.6.1.4.1.4756.20.302.40.1.133Columnf1000EASXOamInfoChBRxRemoteBread-onlycurrentRemoteB device OAM Channel B RX Information OAMPDU frame count
1.3.6.1.4.1.4756.20.302.40.1.134Columnf1000EASXOamEventChBTxRemoteBread-onlycurrentRemoteB device OAM Channel B TX Event OAMPDU frame count
1.3.6.1.4.1.4756.20.302.40.1.135Columnf1000EASXOamUniEvtChBRxRemoteBread-onlycurrentRemoteB device OAM Channel B RX Unique Event OAMPDU frame count
1.3.6.1.4.1.4756.20.302.40.1.136Columnf1000EASXOamDupEvtChBRxRemoteBread-onlycurrentRemoteB device OAM Channel B RX Duplicate Event OAMPDU frame count
1.3.6.1.4.1.4756.20.302.40.1.137Columnf1000EASXOamLbChBTxRemoteBread-onlycurrentRemoteB device OAM Channel B TX Loopback Control OAMPDU frame count
1.3.6.1.4.1.4756.20.302.40.1.138Columnf1000EASXOamLbChBRxRemoteBread-onlycurrentRemoteB device OAM Channel B RX Loopback Control OAMPDU frame count
1.3.6.1.4.1.4756.20.302.40.1.139Columnf1000EASXOamVarReqChBTxRemoteBread-onlycurrentRemoteB device OAM Channel B TX Variable Request OAMPDU frame count
1.3.6.1.4.1.4756.20.302.40.1.140Columnf1000EASXOamVarReqChBRxRemoteBread-onlycurrentRemoteB device OAM Channel B RX Variable Request OAMPDU frame count
1.3.6.1.4.1.4756.20.302.40.1.141Columnf1000EASXOamVarRspChBTxRemoteBread-onlycurrentRemoteB device OAM Channel B TX Variable Response OAMPDU frame count
1.3.6.1.4.1.4756.20.302.40.1.142Columnf1000EASXOamVarRspChBRxRemoteBread-onlycurrentRemoteB device OAM Channel B RX Variable Response OAMPDU frame count
1.3.6.1.4.1.4756.20.302.40.1.143Columnf1000EASXOamOuiChBTxRemoteBread-onlycurrentRemoteB device OAM Channel B TX OUI OAMPDU frame count
1.3.6.1.4.1.4756.20.302.40.1.144Columnf1000EASXOamOuiChBRxRemoteBread-onlycurrentRemoteB device OAM Channel B RX OUI OAMPDU frame count
1.3.6.1.4.1.4756.20.302.40.1.145Columnf1000EASXOamUnknowChBRxRemoteBread-onlycurrentRemoteB device OAM Channel B RX Unsupported OAMPDU frame count
1.3.6.1.4.1.4756.20.302.40.1.146Columnf1000EASXFiber1SpeedRemoteBread-onlycurrentRemoteB device Fiber 1 speed : 0:1000Auto 1:1000FDX 2:100FDX
1.3.6.1.4.1.4756.20.302.40.1.147Columnf1000EASXFiber2SpeedRemoteBread-onlycurrentRemoteB device Fiber 2 speed : 0:1000Auto 1:1000FDX 2:100FDX
1.3.6.1.4.1.4756.20.302.40.1.148Columnf1000EASXMacLearningRemoteBread-writecurrentRemoteB device Mac learning : 0:Disable 1:Enable
1.3.6.1.4.1.4756.20.302.40.1.149Columnf1000EASXFiber1VLANRemoteBread-writecurrentRemoteB device Fiber 1 VLAN group : 0:Group A 1:Group B
1.3.6.1.4.1.4756.20.302.40.1.150Columnf1000EASXFiber2VLANRemoteBread-writecurrentRemoteB device Fiber 2 VLAN group : 0:Group A 1:Group B
1.3.6.1.4.1.4756.20.302.40.1.151Columnf1000EASXUtp3VLANRemoteBread-writecurrentRemoteB device UTP 3 VLAN group : 0:Group A 1:Group B
1.3.6.1.4.1.4756.20.302.40.1.152Columnf1000EASXUtp4VLANRemoteBread-writecurrentRemoteB device UTP 4 VLAN group : 0:Group A 1:Group B
1.3.6.1.4.1.4756.20.302.40.1.153Columnf1000EASXManagementRemoteBread-writecurrentRemoteB device management : 0:Group A 1:Group B 2:Group A+B
1.3.6.1.4.1.4756.20.302.40.1.154Columnf1000EASXRedundancyModeRemoteBread-writecurrentRemoteB device redundancy mode : 0:Auto 1:Manual Fiber 1 2:Manual Fiber 2 3:No Reverse 4:Link Budget
1.3.6.1.4.1.4756.20.302.40.1.155Columnf1000EASXPortVLANRemoteBread-writecurrentRemoteB device redundancy mode : 0:Disalbe 1:Enable
1.3.6.1.4.1.4756.20.302.40.1.156Columnf1000EASXRemoteTLPTRemoteBread-writecurrentRemoteB device redundancy mode : 0:Disalbe 1:Remote A 2:Remote B 3:Remote A&B 4:Remote A/3; Remote B/4
1.3.6.1.4.1.4756.20.302.40.1.157Columnf1000EASXManagementVIDRemoteBread-writecurrentRemoteB device Management VID :
1.3.6.1.4.1.4756.20.302.40.1.158Columnf1000EASXThresholdRemoteBread-writecurrentRemoteB device Threshold:
1.3.6.1.4.1.4756.20.302.40.1.159Columnf1000EASXSensitivityRemoteBread-writecurrentRemoteB device Sensitivity:
1.3.6.1.4.1.4756.20.302.40.1.160Columnf1000EASXTagTypeRemoteBread-writecurrentRemoteB device Tag Type (HEX) :
1.3.6.1.4.1.4756.20.302.40.1.161Columnf1000EASXPort1VIDRemoteBread-writecurrentRemoteB device Port 1 VID :
1.3.6.1.4.1.4756.20.302.40.1.162Columnf1000EASXPort2VIDRemoteBread-writecurrentRemoteB device Port 2 VID :
1.3.6.1.4.1.4756.20.302.40.1.163Columnf1000EASXPort3VIDRemoteBread-writecurrentRemoteB device Port 3 VID :
1.3.6.1.4.1.4756.20.302.40.1.164Columnf1000EASXPort4VIDRemoteBread-writecurrentRemoteB device Port 4 VID :
1.3.6.1.4.1.4756.20.302.40.1.165Columnf1000EASXPort1QinQRemoteBread-writecurrentRemoteB device Port 1 Q in Q Support : 1:Disable 2:Enable
1.3.6.1.4.1.4756.20.302.40.1.166Columnf1000EASXPort2QinQRemoteBread-writecurrentRemoteB device Port 2 Q in Q Support : 1:Disable 2:Enable
1.3.6.1.4.1.4756.20.302.40.1.167Columnf1000EASXPort3QinQRemoteBread-writecurrentRemoteB device Port 3 Q in Q Support : 1:Disable 2:Enable
1.3.6.1.4.1.4756.20.302.40.1.168Columnf1000EASXPort4QinQRemoteBread-writecurrentRemoteB device Port 4 Q in Q Support : 1:Disable 2:Enable
1.3.6.1.4.1.4756.20.302.40.1.169Columnf1000EASXVID1RemoteBread-writecurrentRemoteB device VID 1:
1.3.6.1.4.1.4756.20.302.40.1.170Columnf1000EASXVID2RemoteBread-writecurrentRemoteB device VID 2:
1.3.6.1.4.1.4756.20.302.40.1.171Columnf1000EASXVID3RemoteBread-writecurrentRemoteB device VID 3:
1.3.6.1.4.1.4756.20.302.40.1.172Columnf1000EASXVID4RemoteBread-writecurrentRemoteB device VID 4:
1.3.6.1.4.1.4756.20.302.40.1.173Columnf1000EASXVID5RemoteBread-writecurrentRemoteB device VID 5:
1.3.6.1.4.1.4756.20.302.40.1.174Columnf1000EASXVID6RemoteBread-writecurrentRemoteB device VID 6:
1.3.6.1.4.1.4756.20.302.40.1.175Columnf1000EASXVID7RemoteBread-writecurrentRemoteB device VID 7:
1.3.6.1.4.1.4756.20.302.40.1.176Columnf1000EASXVID8RemoteBread-writecurrentRemoteB device VID 8:
1.3.6.1.4.1.4756.20.302.40.1.177Columnf1000EASXVID9RemoteBread-writecurrentRemoteB device VID 9:
1.3.6.1.4.1.4756.20.302.40.1.178Columnf1000EASXVID10RemoteBread-writecurrentRemoteB device VID 10:
1.3.6.1.4.1.4756.20.302.40.1.179Columnf1000EASXVID11RemoteBread-writecurrentRemoteB device VID 11:
1.3.6.1.4.1.4756.20.302.40.1.180Columnf1000EASXVID12RemoteBread-writecurrentRemoteB device VID 12:
1.3.6.1.4.1.4756.20.302.40.1.181Columnf1000EASXVID13RemoteBread-writecurrentRemoteB device VID 13:
1.3.6.1.4.1.4756.20.302.40.1.182Columnf1000EASXVID14RemoteBread-writecurrentRemoteB device VID 14:
1.3.6.1.4.1.4756.20.302.40.1.183Columnf1000EASXVID15RemoteBread-writecurrentRemoteB device VID 15:
1.3.6.1.4.1.4756.20.302.40.1.184Columnf1000EASXVID16RemoteBread-writecurrentRemoteB device VID 16:
1.3.6.1.4.1.4756.20.302.40.1.185Columnf1000EASXPort1Member1RemoteBread-writecurrentRemoteB device card port 1 member: 0:Unmodify 1:Untagged 2:Tagged 3:Nonmember
1.3.6.1.4.1.4756.20.302.40.1.186Columnf1000EASXPort1Member2RemoteBread-writecurrentRemoteB device card port 1 member 2: 0:Unmodify 1:Untagged 2:Tagged 3:Nonmember
1.3.6.1.4.1.4756.20.302.40.1.187Columnf1000EASXPort1Member3RemoteBread-writecurrentRemoteB device card port 1 member 3: 0:Unmodify 1:Untagged 2:Tagged 3:Nonmember
1.3.6.1.4.1.4756.20.302.40.1.188Columnf1000EASXPort1Member4RemoteBread-writecurrentRemoteB device card port 1 member 4: 0:Unmodify 1:Untagged 2:Tagged 3:Nonmember
1.3.6.1.4.1.4756.20.302.40.1.189Columnf1000EASXPort1Member5RemoteBread-writecurrentRemoteB device card port 1 member 5: 0:Unmodify 1:Untagged 2:Tagged 3:Nonmember
1.3.6.1.4.1.4756.20.302.40.1.190Columnf1000EASXPort1Member6RemoteBread-writecurrentRemoteB device card port 1 member 6: 0:Unmodify 1:Untagged 2:Tagged 3:Nonmember
1.3.6.1.4.1.4756.20.302.40.1.191Columnf1000EASXPort1Member7RemoteBread-writecurrentRemoteB device card port 1 member 7: 0:Unmodify 1:Untagged 2:Tagged 3:Nonmember
1.3.6.1.4.1.4756.20.302.40.1.192Columnf1000EASXPort1Member8RemoteBread-writecurrentRemoteB device card port 1 member 8: 0:Unmodify 1:Untagged 2:Tagged 3:Nonmember
1.3.6.1.4.1.4756.20.302.40.1.193Columnf1000EASXPort1Member9RemoteBread-writecurrentRemoteB device card port 1 member 9: 0:Unmodify 1:Untagged 2:Tagged 3:Nonmember
1.3.6.1.4.1.4756.20.302.40.1.194Columnf1000EASXPort1Member10RemoteBread-writecurrentRemoteB device card port 1 member 10: 0:Unmodify 1:Untagged 2:Tagged 3:Nonmember
1.3.6.1.4.1.4756.20.302.40.1.195Columnf1000EASXPort1Member11RemoteBread-writecurrentRemoteB device card port 1 member 11: 0:Unmodify 1:Untagged 2:Tagged 3:Nonmember
1.3.6.1.4.1.4756.20.302.40.1.196Columnf1000EASXPort1Member12RemoteBread-writecurrentRemoteB device card port 1 member 12: 0:Unmodify 1:Untagged 2:Tagged 3:Nonmember
1.3.6.1.4.1.4756.20.302.40.1.197Columnf1000EASXPort1Member13RemoteBread-writecurrentRemoteB device card port 1 member 13: 0:Unmodify 1:Untagged 2:Tagged 3:Nonmember
1.3.6.1.4.1.4756.20.302.40.1.198Columnf1000EASXPort1Member14RemoteBread-writecurrentRemoteB device card port 1 member 14: 0:Unmodify 1:Untagged 2:Tagged 3:Nonmember
1.3.6.1.4.1.4756.20.302.40.1.199Columnf1000EASXPort1Member15RemoteBread-writecurrentRemoteB device card port 1 member 15: 0:Unmodify 1:Untagged 2:Tagged 3:Nonmember
1.3.6.1.4.1.4756.20.302.40.1.200Columnf1000EASXPort1Member16RemoteBread-writecurrentRemoteB device card port 1 member 16: 0:Unmodify 1:Untagged 2:Tagged 3:Nonmember
1.3.6.1.4.1.4756.20.302.40.1.201Columnf1000EASXPort2Member1RemoteBread-writecurrentRemoteB device card port 2 member: 0:Unmodify 1:Untagged 2:Tagged 3:Nonmember
1.3.6.1.4.1.4756.20.302.40.1.202Columnf1000EASXPort2Member2RemoteBread-writecurrentRemoteB device card port 2 member 2: 0:Unmodify 1:Untagged 2:Tagged 3:Nonmember
1.3.6.1.4.1.4756.20.302.40.1.203Columnf1000EASXPort2Member3RemoteBread-writecurrentRemoteB device card port 2 member 3: 0:Unmodify 1:Untagged 2:Tagged 3:Nonmember
1.3.6.1.4.1.4756.20.302.40.1.204Columnf1000EASXPort2Member4RemoteBread-writecurrentRemoteB device card port 2 member 4: 0:Unmodify 1:Untagged 2:Tagged 3:Nonmember
1.3.6.1.4.1.4756.20.302.40.1.205Columnf1000EASXPort2Member5RemoteBread-writecurrentRemoteB device card port 2 member 5: 0:Unmodify 1:Untagged 2:Tagged 3:Nonmember
1.3.6.1.4.1.4756.20.302.40.1.206Columnf1000EASXPort2Member6RemoteBread-writecurrentRemoteB device card port 2 member 6: 0:Unmodify 1:Untagged 2:Tagged 3:Nonmember
1.3.6.1.4.1.4756.20.302.40.1.207Columnf1000EASXPort2Member7RemoteBread-writecurrentRemoteB device card port 2 member 7: 0:Unmodify 1:Untagged 2:Tagged 3:Nonmember
1.3.6.1.4.1.4756.20.302.40.1.208Columnf1000EASXPort2Member8RemoteBread-writecurrentRemoteB device card port 2 member 8: 0:Unmodify 1:Untagged 2:Tagged 3:Nonmember
1.3.6.1.4.1.4756.20.302.40.1.209Columnf1000EASXPort2Member9RemoteBread-writecurrentRemoteB device card port 2 member 9: 0:Unmodify 1:Untagged 2:Tagged 3:Nonmember
1.3.6.1.4.1.4756.20.302.40.1.210Columnf1000EASXPort2Member10RemoteBread-writecurrentRemoteB device card port 2 member 10: 0:Unmodify 1:Untagged 2:Tagged 3:Nonmember
1.3.6.1.4.1.4756.20.302.40.1.211Columnf1000EASXPort2Member11RemoteBread-writecurrentRemoteB device card port 2 member 11: 0:Unmodify 1:Untagged 2:Tagged 3:Nonmember
1.3.6.1.4.1.4756.20.302.40.1.212Columnf1000EASXPort2Member12RemoteBread-writecurrentRemoteB device card port 2 member 12: 0:Unmodify 1:Untagged 2:Tagged 3:Nonmember
1.3.6.1.4.1.4756.20.302.40.1.213Columnf1000EASXPort2Member13RemoteBread-writecurrentRemoteB device card port 2 member 13: 0:Unmodify 1:Untagged 2:Tagged 3:Nonmember
1.3.6.1.4.1.4756.20.302.40.1.214Columnf1000EASXPort2Member14RemoteBread-writecurrentRemoteB device card port 2 member 14: 0:Unmodify 1:Untagged 2:Tagged 3:Nonmember
1.3.6.1.4.1.4756.20.302.40.1.215Columnf1000EASXPort2Member15RemoteBread-writecurrentRemoteB device card port 2 member 15: 0:Unmodify 1:Untagged 2:Tagged 3:Nonmember
1.3.6.1.4.1.4756.20.302.40.1.216Columnf1000EASXPort2Member16RemoteBread-writecurrentRemoteB device card port 2 member 16: 0:Unmodify 1:Untagged 2:Tagged 3:Nonmember
1.3.6.1.4.1.4756.20.302.40.1.217Columnf1000EASXPort3Member1RemoteBread-writecurrentRemoteB device card port 3 member: 0:Unmodify 1:Untagged 2:Tagged 3:Nonmember
1.3.6.1.4.1.4756.20.302.40.1.218Columnf1000EASXPort3Member2RemoteBread-writecurrentRemoteB device card port 3 member 2: 0:Unmodify 1:Untagged 2:Tagged 3:Nonmember
1.3.6.1.4.1.4756.20.302.40.1.219Columnf1000EASXPort3Member3RemoteBread-writecurrentRemoteB device card port 3 member 3: 0:Unmodify 1:Untagged 2:Tagged 3:Nonmember
1.3.6.1.4.1.4756.20.302.40.1.220Columnf1000EASXPort3Member4RemoteBread-writecurrentRemoteB device card port 3 member 4: 0:Unmodify 1:Untagged 2:Tagged 3:Nonmember
1.3.6.1.4.1.4756.20.302.40.1.221Columnf1000EASXPort3Member5RemoteBread-writecurrentRemoteB device card port 3 member 5: 0:Unmodify 1:Untagged 2:Tagged 3:Nonmember
1.3.6.1.4.1.4756.20.302.40.1.222Columnf1000EASXPort3Member6RemoteBread-writecurrentRemoteB device card port 3 member 6: 0:Unmodify 1:Untagged 2:Tagged 3:Nonmember
1.3.6.1.4.1.4756.20.302.40.1.223Columnf1000EASXPort3Member7RemoteBread-writecurrentRemoteB device card port 3 member 7: 0:Unmodify 1:Untagged 2:Tagged 3:Nonmember
1.3.6.1.4.1.4756.20.302.40.1.224Columnf1000EASXPort3Member8RemoteBread-writecurrentRemoteB device card port 3 member 8: 0:Unmodify 1:Untagged 2:Tagged 3:Nonmember
1.3.6.1.4.1.4756.20.302.40.1.225Columnf1000EASXPort3Member9RemoteBread-writecurrentRemoteB device card port 3 member 9: 0:Unmodify 1:Untagged 2:Tagged 3:Nonmember
1.3.6.1.4.1.4756.20.302.40.1.226Columnf1000EASXPort3Member10RemoteBread-writecurrentRemoteB device card port 3 member 10: 0:Unmodify 1:Untagged 2:Tagged 3:Nonmember
1.3.6.1.4.1.4756.20.302.40.1.227Columnf1000EASXPort3Member11RemoteBread-writecurrentRemoteB device card port 3 member 11: 0:Unmodify 1:Untagged 2:Tagged 3:Nonmember
1.3.6.1.4.1.4756.20.302.40.1.228Columnf1000EASXPort3Member12RemoteBread-writecurrentRemoteB device card port 3 member 12: 0:Unmodify 1:Untagged 2:Tagged 3:Nonmember
1.3.6.1.4.1.4756.20.302.40.1.229Columnf1000EASXPort3Member13RemoteBread-writecurrentRemoteB device card port 3 member 13: 0:Unmodify 1:Untagged 2:Tagged 3:Nonmember
1.3.6.1.4.1.4756.20.302.40.1.230Columnf1000EASXPort3Member14RemoteBread-writecurrentRemoteB device card port 3 member 14: 0:Unmodify 1:Untagged 2:Tagged 3:Nonmember
1.3.6.1.4.1.4756.20.302.40.1.231Columnf1000EASXPort3Member15RemoteBread-writecurrentRemoteB device card port 3 member 15: 0:Unmodify 1:Untagged 2:Tagged 3:Nonmember
1.3.6.1.4.1.4756.20.302.40.1.232Columnf1000EASXPort3Member16RemoteBread-writecurrentRemoteB device card port 3 member 16: 0:Unmodify 1:Untagged 2:Tagged 3:Nonmember
1.3.6.1.4.1.4756.20.302.40.1.233Columnf1000EASXPort4Member1RemoteBread-writecurrentRemoteB device card port 4 member: 0:Unmodify 1:Untagged 2:Tagged 3:Nonmember
1.3.6.1.4.1.4756.20.302.40.1.234Columnf1000EASXPort4Member2RemoteBread-writecurrentRemoteB device card port 4 member 2: 0:Unmodify 1:Untagged 2:Tagged 3:Nonmember
1.3.6.1.4.1.4756.20.302.40.1.235Columnf1000EASXPort4Member3RemoteBread-writecurrentRemoteB device card port 4 member 3: 0:Unmodify 1:Untagged 2:Tagged 3:Nonmember
1.3.6.1.4.1.4756.20.302.40.1.236Columnf1000EASXPort4Member4RemoteBread-writecurrentRemoteB device card port 4 member 4: 0:Unmodify 1:Untagged 2:Tagged 3:Nonmember
1.3.6.1.4.1.4756.20.302.40.1.237Columnf1000EASXPort4Member5RemoteBread-writecurrentRemoteB device card port 4 member 5: 0:Unmodify 1:Untagged 2:Tagged 3:Nonmember
1.3.6.1.4.1.4756.20.302.40.1.238Columnf1000EASXPort4Member6RemoteBread-writecurrentRemoteB device card port 4 member 6: 0:Unmodify 1:Untagged 2:Tagged 3:Nonmember
1.3.6.1.4.1.4756.20.302.40.1.239Columnf1000EASXPort4Member7RemoteBread-writecurrentRemoteB device card port 4 member 7: 0:Unmodify 1:Untagged 2:Tagged 3:Nonmember
1.3.6.1.4.1.4756.20.302.40.1.240Columnf1000EASXPort4Member8RemoteBread-writecurrentRemoteB device card port 4 member 8: 0:Unmodify 1:Untagged 2:Tagged 3:Nonmember
1.3.6.1.4.1.4756.20.302.40.1.241Columnf1000EASXPort4Member9RemoteBread-writecurrentRemoteB device card port 4 member 9: 0:Unmodify 1:Untagged 2:Tagged 3:Nonmember
1.3.6.1.4.1.4756.20.302.40.1.242Columnf1000EASXPort4Member10RemoteBread-writecurrentRemoteB device card port 4 member 10: 0:Unmodify 1:Untagged 2:Tagged 3:Nonmember
1.3.6.1.4.1.4756.20.302.40.1.243Columnf1000EASXPort4Member11RemoteBread-writecurrentRemoteB device card port 4 member 11: 0:Unmodify 1:Untagged 2:Tagged 3:Nonmember
1.3.6.1.4.1.4756.20.302.40.1.244Columnf1000EASXPort4Member12RemoteBread-writecurrentRemoteB device card port 4 member 12: 0:Unmodify 1:Untagged 2:Tagged 3:Nonmember
1.3.6.1.4.1.4756.20.302.40.1.245Columnf1000EASXPort4Member13RemoteBread-writecurrentRemoteB device card port 4 member 13: 0:Unmodify 1:Untagged 2:Tagged 3:Nonmember
1.3.6.1.4.1.4756.20.302.40.1.246Columnf1000EASXPort4Member14RemoteBread-writecurrentRemoteB device card port 4 member 14: 0:Unmodify 1:Untagged 2:Tagged 3:Nonmember
1.3.6.1.4.1.4756.20.302.40.1.247Columnf1000EASXPort4Member15RemoteBread-writecurrentRemoteB device card port 4 member 15: 0:Unmodify 1:Untagged 2:Tagged 3:Nonmember
1.3.6.1.4.1.4756.20.302.40.1.248Columnf1000EASXPort4Member16RemoteBread-writecurrentRemoteB device card port 4 member 16: 0:Unmodify 1:Untagged 2:Tagged 3:Nonmember
1.3.6.1.4.1.4756.20.302.40.1.249Columnf1000EASXIpAddressRemoteBread-writecurrentRemoteB device IP address
1.3.6.1.4.1.4756.20.302.40.1.250Columnf1000EASXNetMaskRemoteBread-writecurrentRemoteB device Netmask
1.3.6.1.4.1.4756.20.302.40.1.251Columnf1000EASXGateWayRemoteBread-writecurrentRemoteB device Gateway
1.3.6.1.4.1.4756.20.302.40.1.252Columnf1000EASXSetDefaultRemoteBread-writecurrentRemoteB device set to default
1.3.6.1.4.1.4756.20.302.40.1.253Columnf1000EASXFx1LinkAlarmRemoteBread-writecurrentRemoteB device fiber 1 link alarm 0:Disable 1:Enable
1.3.6.1.4.1.4756.20.302.40.1.254Columnf1000EASXFx2LinkAlarmRemoteBread-writecurrentRemoteB device fiber 2 link alarm 0:Disable 1:Enable
1.3.6.1.4.1.4756.20.302.40.1.255Columnf1000EASXUtp3LinkAlarmRemoteBread-writecurrentRemoteB device utp 3 link alarm 0:Disable 1:Enable
1.3.6.1.4.1.4756.20.302.40.1.256Columnf1000EASXUtp4LinkAlarmRemoteBread-writecurrentRemoteB device utp 4 link alarm 0:Disable 1:Enable
1.3.6.1.4.1.4756.20.302.40.1.257Columnf1000EASXFiber1FEFRemoteBread-onlycurrentRemoteA device card fiber1 port FEF status: 0:Off 1:Detected
1.3.6.1.4.1.4756.20.302.40.1.258Columnf1000EASXFiber2FEFRemoteBread-onlycurrentRemoteA device card fiber2 port FEF status: 0:Off 1:Detected
1.3.6.1.4.1.4756.20.302.40.1.259Columnf1000EASXFX1RXOctetsRemoteBread-onlycurrentFRM220-1000EAS/X RMON Fiber 1 Receiver Octets.
1.3.6.1.4.1.4756.20.302.40.1.260Columnf1000EASXFX1RXPacketRemoteBread-onlycurrentFRM220-1000EAS/X RMON Fiber 1 Receiver Packets.
1.3.6.1.4.1.4756.20.302.40.1.261Columnf1000EASXFX1RXBroadRemoteBread-onlycurrentFRM220-1000EAS/X RMON Fiber 1 Receiver Broadcast Packets.
1.3.6.1.4.1.4756.20.302.40.1.262Columnf1000EASXFX1RXMultiRemoteBread-onlycurrentFRM220-1000EAS/X RMON Fiber 1 Receiver Multicast Packets.
1.3.6.1.4.1.4756.20.302.40.1.263Columnf1000EASXFX1RXUniRemoteBread-onlycurrentFRM220-1000EAS/X RMON Fiber 1 Receiver Unicast Packets.
1.3.6.1.4.1.4756.20.302.40.1.264Columnf1000EASXFX1RXPauseRemoteBread-onlycurrentFRM220-1000EAS/X RMON Fiber 1 Receiver Pause Packets.
1.3.6.1.4.1.4756.20.302.40.1.265Columnf1000EASXFX1RXFCSERemoteBread-onlycurrentFRM220-1000EAS/X RMON Fiber 1 Receiver FCS Error Packets.
1.3.6.1.4.1.4756.20.302.40.1.266Columnf1000EASXFX1RXUnderRemoteBread-onlycurrentFRM220-1000EAS/X RMON Fiber 1 Receiver Under Packets.
1.3.6.1.4.1.4756.20.302.40.1.267Columnf1000EASXFX1RXOverRemoteBread-onlycurrentFRM220-1000EAS/X RMON Fiber 1 Receiver Over Packets.
1.3.6.1.4.1.4756.20.302.40.1.268Columnf1000EASXFX1RXJabberRemoteBread-onlycurrentFRM220-1000EAS/X RMON Fiber 1 Receiver Jabber Packets.
1.3.6.1.4.1.4756.20.302.40.1.269Columnf1000EASXFX1TXOctetsRemoteBread-onlycurrentFRM220-1000EAS/X RMON Fiber 1 Transceiver Octets.
1.3.6.1.4.1.4756.20.302.40.1.270Columnf1000EASXFX1TXPacketRemoteBread-onlycurrentFRM220-1000EAS/X RMON Fiber 1 Transceiver Packets.
1.3.6.1.4.1.4756.20.302.40.1.271Columnf1000EASXFX1TXBroadRemoteBread-onlycurrentFRM220-1000EAS/X RMON Fiber 1 Transceiver Broadcast Packets.
1.3.6.1.4.1.4756.20.302.40.1.272Columnf1000EASXFX1TXMultiRemoteBread-onlycurrentFRM220-1000EAS/X RMON Fiber 1 Transceiver Multicast Packets.
1.3.6.1.4.1.4756.20.302.40.1.273Columnf1000EASXFX1TXUniRemoteBread-onlycurrentFRM220-1000EAS/X RMON Fiber 1 Transceiver Unicast Packets.
1.3.6.1.4.1.4756.20.302.40.1.274Columnf1000EASXFX1TXPauseRemoteBread-onlycurrentFRM220-1000EAS/X RMON Fiber 1 Transceiver Pause Packets.
1.3.6.1.4.1.4756.20.302.40.1.275Columnf1000EASXFX1TXCollisionRemoteBread-onlycurrentFRM220-1000EAS/X RMON Fiber 1 Transceiver Collision Packets.
1.3.6.1.4.1.4756.20.302.40.1.276Columnf1000EASXFX10OctetsRemoteBread-onlycurrentFRM220-1000EAS/X RMON Fiber 1 Transceiver/Receiver 0~64 Octets.
1.3.6.1.4.1.4756.20.302.40.1.277Columnf1000EASXFX165OctetsRemoteBread-onlycurrentFRM220-1000EAS/X RMON Fiber 1 Transceiver/Receiver 65~127 Octets.
1.3.6.1.4.1.4756.20.302.40.1.278Columnf1000EASXFX1128OctetsRemoteBread-onlycurrentFRM220-1000EAS/X RMON Fiber 1 Transceiver/Receiver 128~255 Octets.
1.3.6.1.4.1.4756.20.302.40.1.279Columnf1000EASXFX1256OctetsRemoteBread-onlycurrentFRM220-1000EAS/X RMON Fiber 1 Transceiver/Receiver 256~511 Octets.
1.3.6.1.4.1.4756.20.302.40.1.280Columnf1000EASXFX1512OctetsRemoteBread-onlycurrentFRM220-1000EAS/X RMON Fiber 1 Transceiver/Receiver 512~1023 Octets.
1.3.6.1.4.1.4756.20.302.40.1.281Columnf1000EASXFX11024OctetsRemoteBread-onlycurrentFRM220-1000EAS/X RMON Fiber 1 Transceiver/Receiver 1024~Max Octets.
1.3.6.1.4.1.4756.20.302.40.1.282Columnf1000EASXFX2RXOctetsRemoteBread-onlycurrentFRM220-1000EAS/X RMON Fiber 2 Receiver Octets.
1.3.6.1.4.1.4756.20.302.40.1.283Columnf1000EASXFX2RXPacketRemoteBread-onlycurrentFRM220-1000EAS/X RMON Fiber 2 Receiver Packets.
1.3.6.1.4.1.4756.20.302.40.1.284Columnf1000EASXFX2RXBroadRemoteBread-onlycurrentFRM220-1000EAS/X RMON Fiber 2 Receiver Broadcast Packets.
1.3.6.1.4.1.4756.20.302.40.1.285Columnf1000EASXFX2RXMultiRemoteBread-onlycurrentFRM220-1000EAS/X RMON Fiber 2 Receiver Multicast Packets.
1.3.6.1.4.1.4756.20.302.40.1.286Columnf1000EASXFX2RXUniRemoteBread-onlycurrentFRM220-1000EAS/X RMON Fiber 2 Receiver Unicast Packets.
1.3.6.1.4.1.4756.20.302.40.1.287Columnf1000EASXFX2RXPauseRemoteBread-onlycurrentFRM220-1000EAS/X RMON Fiber 2 Receiver Pause Packets.
1.3.6.1.4.1.4756.20.302.40.1.288Columnf1000EASXFX2RXFCSERemoteBread-onlycurrentFRM220-1000EAS/X RMON Fiber 2 Receiver FCS Error Packets.
1.3.6.1.4.1.4756.20.302.40.1.289Columnf1000EASXFX2RXUnderRemoteBread-onlycurrentFRM220-1000EAS/X RMON Fiber 2 Receiver Under Packets.
1.3.6.1.4.1.4756.20.302.40.1.290Columnf1000EASXFX2RXOverRemoteBread-onlycurrentFRM220-1000EAS/X RMON Fiber 2 Receiver Over Packets.
1.3.6.1.4.1.4756.20.302.40.1.291Columnf1000EASXFX2RXJabberRemoteBread-onlycurrentFRM220-1000EAS/X RMON Fiber 2 Receiver Jabber Packets.
1.3.6.1.4.1.4756.20.302.40.1.292Columnf1000EASXFX2TXOctetsRemoteBread-onlycurrentFRM220-1000EAS/X RMON Fiber 2 Transceiver Octets.
1.3.6.1.4.1.4756.20.302.40.1.293Columnf1000EASXFX2TXPacketRemoteBread-onlycurrentFRM220-1000EAS/X RMON Fiber 2 Transceiver Packets.
1.3.6.1.4.1.4756.20.302.40.1.294Columnf1000EASXFX2TXBroadRemoteBread-onlycurrentFRM220-1000EAS/X RMON Fiber 2 Transceiver Broadcast Packets.
1.3.6.1.4.1.4756.20.302.40.1.295Columnf1000EASXFX2TXMultiRemoteBread-onlycurrentFRM220-1000EAS/X RMON Fiber 2 Transceiver Multicast Packets.
1.3.6.1.4.1.4756.20.302.40.1.296Columnf1000EASXFX2TXUniRemoteBread-onlycurrentFRM220-1000EAS/X RMON Fiber 2 Transceiver Unicast Packets.
1.3.6.1.4.1.4756.20.302.40.1.297Columnf1000EASXFX2TXPauseRemoteBread-onlycurrentFRM220-1000EAS/X RMON Fiber 2 Transceiver Pause Packets.
1.3.6.1.4.1.4756.20.302.40.1.298Columnf1000EASXFX2TXCollisionRemoteBread-onlycurrentFRM220-1000EAS/X RMON Fiber 2 Transceiver Collision Packets.
1.3.6.1.4.1.4756.20.302.40.1.299Columnf1000EASXFX20OctetsRemoteBread-onlycurrentFRM220-1000EAS/X RMON Fiber 2 Transceiver/Receiver 0~64 Octets.
1.3.6.1.4.1.4756.20.302.40.1.300Columnf1000EASXFX265OctetsRemoteBread-onlycurrentFRM220-1000EAS/X RMON Fiber 2 Transceiver/Receiver 65~127 Octets.
1.3.6.1.4.1.4756.20.302.40.1.301Columnf1000EASXFX2128OctetsRemoteBread-onlycurrentFRM220-1000EAS/X RMON Fiber 2 Transceiver/Receiver 128~255 Octets.
1.3.6.1.4.1.4756.20.302.40.1.302Columnf1000EASXFX2256OctetsRemoteBread-onlycurrentFRM220-1000EAS/X RMON Fiber 2 Transceiver/Receiver 256~511 Octets.
1.3.6.1.4.1.4756.20.302.40.1.303Columnf1000EASXFX2512OctetsRemoteBread-onlycurrentFRM220-1000EAS/X RMON Fiber 2 Transceiver/Receiver 512~1023 Octets.
1.3.6.1.4.1.4756.20.302.40.1.304Columnf1000EASXFX21024OctetsRemoteBread-onlycurrentFRM220-1000EAS/X RMON Fiber 2 Transceiver/Receiver 1024~Max Octets.
1.3.6.1.4.1.4756.20.302.40.1.305Columnf1000EASXUTP3RXOctetsRemoteBread-onlycurrentFRM220-1000EAS/X RMON UTP 3 Receiver Octets.
1.3.6.1.4.1.4756.20.302.40.1.306Columnf1000EASXUTP3RXPacketRemoteBread-onlycurrentFRM220-1000EAS/X RMON UTP 3 Receiver Packets.
1.3.6.1.4.1.4756.20.302.40.1.307Columnf1000EASXUTP3RXBroadRemoteBread-onlycurrentFRM220-1000EAS/X RMON UTP 3 Receiver Broadcast Packets.
1.3.6.1.4.1.4756.20.302.40.1.308Columnf1000EASXUTP3RXMultiRemoteBread-onlycurrentFRM220-1000EAS/X RMON UTP 3 Receiver Multicast Packets.
1.3.6.1.4.1.4756.20.302.40.1.309Columnf1000EASXUTP3RXUniRemoteBread-onlycurrentFRM220-1000EAS/X RMON UTP 3 Receiver Unicast Packets.
1.3.6.1.4.1.4756.20.302.40.1.310Columnf1000EASXUTP3RXPauseRemoteBread-onlycurrentFRM220-1000EAS/X RMON UTP 3 Receiver Pause Packets.
1.3.6.1.4.1.4756.20.302.40.1.311Columnf1000EASXUTP3RXFCSERemoteBread-onlycurrentFRM220-1000EAS/X RMON UTP 3 Receiver FCS Error Packets.
1.3.6.1.4.1.4756.20.302.40.1.312Columnf1000EASXUTP3RXUnderRemoteBread-onlycurrentFRM220-1000EAS/X RMON UTP 3 Receiver Under Packets.
1.3.6.1.4.1.4756.20.302.40.1.313Columnf1000EASXUTP3RXOverRemoteBread-onlycurrentFRM220-1000EAS/X RMON UTP 3 Receiver Over Packets.
1.3.6.1.4.1.4756.20.302.40.1.314Columnf1000EASXUTP3RXJabberRemoteBread-onlycurrentFRM220-1000EAS/X RMON UTP 3 Receiver Jabber Packets.
1.3.6.1.4.1.4756.20.302.40.1.315Columnf1000EASXUTP3TXOctetsRemoteBread-onlycurrentFRM220-1000EAS/X RMON UTP 3 Transceiver Octets.
1.3.6.1.4.1.4756.20.302.40.1.316Columnf1000EASXUTP3TXPacketRemoteBread-onlycurrentFRM220-1000EAS/X RMON UTP 3 Transceiver Packets.
1.3.6.1.4.1.4756.20.302.40.1.317Columnf1000EASXUTP3TXBroadRemoteBread-onlycurrentFRM220-1000EAS/X RMON UTP 3 Transceiver Broadcast Packets.
1.3.6.1.4.1.4756.20.302.40.1.318Columnf1000EASXUTP3TXMultiRemoteBread-onlycurrentFRM220-1000EAS/X RMON UTP 3 Transceiver Multicast Packets.
1.3.6.1.4.1.4756.20.302.40.1.319Columnf1000EASXUTP3TXUniRemoteBread-onlycurrentFRM220-1000EAS/X RMON UTP 3 Transceiver Unicast Packets.
1.3.6.1.4.1.4756.20.302.40.1.320Columnf1000EASXUTP3TXPauseRemoteBread-onlycurrentFRM220-1000EAS/X RMON UTP 3 Transceiver Pause Packets.
1.3.6.1.4.1.4756.20.302.40.1.321Columnf1000EASXUTP3TXCollisionRemoteBread-onlycurrentFRM220-1000EAS/X RMON UTP 3 Transceiver Collision Packets.
1.3.6.1.4.1.4756.20.302.40.1.322Columnf1000EASXUTP30OctetsRemoteBread-onlycurrentFRM220-1000EAS/X RMON UTP 3 Transceiver/Receiver 0~64 Octets.
1.3.6.1.4.1.4756.20.302.40.1.323Columnf1000EASXUTP365OctetsRemoteBread-onlycurrentFRM220-1000EAS/X RMON UTP 3 Transceiver/Receiver 65~127 Octets.
1.3.6.1.4.1.4756.20.302.40.1.324Columnf1000EASXUTP3128OctetsRemoteBread-onlycurrentFRM220-1000EAS/X RMON UTP 3 Transceiver/Receiver 128~255 Octets.
1.3.6.1.4.1.4756.20.302.40.1.325Columnf1000EASXUTP3256OctetsRemoteBread-onlycurrentFRM220-1000EAS/X RMON UTP 3 Transceiver/Receiver 256~511 Octets.
1.3.6.1.4.1.4756.20.302.40.1.326Columnf1000EASXUTP3512OctetsRemoteBread-onlycurrentFRM220-1000EAS/X RMON UTP 3 Transceiver/Receiver 512~1023 Octets.
1.3.6.1.4.1.4756.20.302.40.1.327Columnf1000EASXUTP31024OctetsRemoteBread-onlycurrentFRM220-1000EAS/X RMON UTP 3 Transceiver/Receiver 1024~Max Octets.
1.3.6.1.4.1.4756.20.302.40.1.328Columnf1000EASXUTP4RXOctetsRemoteBread-onlycurrentFRM220-1000EAS/X RMON UTP 4 Receiver Octets.
1.3.6.1.4.1.4756.20.302.40.1.329Columnf1000EASXUTP4RXPacketRemoteBread-onlycurrentFRM220-1000EAS/X RMON UTP 4 Receiver Packets.
1.3.6.1.4.1.4756.20.302.40.1.330Columnf1000EASXUTP4RXBroadRemoteBread-onlycurrentFRM220-1000EAS/X RMON UTP 4 Receiver Broadcast Packets.
1.3.6.1.4.1.4756.20.302.40.1.331Columnf1000EASXUTP4RXMultiRemoteBread-onlycurrentFRM220-1000EAS/X RMON UTP 4 Receiver Multicast Packets.
1.3.6.1.4.1.4756.20.302.40.1.332Columnf1000EASXUTP4RXUniRemoteBread-onlycurrentFRM220-1000EAS/X RMON UTP 4 Receiver Unicast Packets.
1.3.6.1.4.1.4756.20.302.40.1.333Columnf1000EASXUTP4RXPauseRemoteBread-onlycurrentFRM220-1000EAS/X RMON UTP 4 Receiver Pause Packets.
1.3.6.1.4.1.4756.20.302.40.1.334Columnf1000EASXUTP4RXFCSERemoteBread-onlycurrentFRM220-1000EAS/X RMON UTP 4 Receiver FCS Error Packets.
1.3.6.1.4.1.4756.20.302.40.1.335Columnf1000EASXUTP4RXUnderRemoteBread-onlycurrentFRM220-1000EAS/X RMON UTP 4 Receiver Under Packets.
1.3.6.1.4.1.4756.20.302.40.1.336Columnf1000EASXUTP4RXOverRemoteBread-onlycurrentFRM220-1000EAS/X RMON UTP 4 Receiver Over Packets.
1.3.6.1.4.1.4756.20.302.40.1.337Columnf1000EASXUTP4RXJabberRemoteBread-onlycurrentFRM220-1000EAS/X RMON UTP 4 Receiver Jabber Packets.
1.3.6.1.4.1.4756.20.302.40.1.338Columnf1000EASXUTP4TXOctetsRemoteBread-onlycurrentFRM220-1000EAS/X RMON UTP 4 Transceiver Octets.
1.3.6.1.4.1.4756.20.302.40.1.339Columnf1000EASXUTP4TXPacketRemoteBread-onlycurrentFRM220-1000EAS/X RMON UTP 4 Transceiver Packets.
1.3.6.1.4.1.4756.20.302.40.1.340Columnf1000EASXUTP4TXBroadRemoteBread-onlycurrentFRM220-1000EAS/X RMON UTP 4 Transceiver Broadcast Packets.
1.3.6.1.4.1.4756.20.302.40.1.341Columnf1000EASXUTP4TXMultiRemoteBread-onlycurrentFRM220-1000EAS/X RMON UTP 4 Transceiver Multicast Packets.
1.3.6.1.4.1.4756.20.302.40.1.342Columnf1000EASXUTP4TXUniRemoteBread-onlycurrentFRM220-1000EAS/X RMON UTP 4 Transceiver Unicast Packets.
1.3.6.1.4.1.4756.20.302.40.1.343Columnf1000EASXUTP4TXPauseRemoteBread-onlycurrentFRM220-1000EAS/X RMON UTP 4 Transceiver Pause Packets.
1.3.6.1.4.1.4756.20.302.40.1.344Columnf1000EASXUTP4TXCollisionRemoteBread-onlycurrentFRM220-1000EAS/X RMON UTP 4 Transceiver Collision Packets.
1.3.6.1.4.1.4756.20.302.40.1.345Columnf1000EASXUTP40OctetsRemoteBread-onlycurrentFRM220-1000EAS/X RMON UTP 4 Transceiver/Receiver 0~64 Octets.
1.3.6.1.4.1.4756.20.302.40.1.346Columnf1000EASXUTP465OctetsRemoteBread-onlycurrentFRM220-1000EAS/X RMON UTP 4 Transceiver/Receiver 65~127 Octets.
1.3.6.1.4.1.4756.20.302.40.1.347Columnf1000EASXUTP4128OctetsRemoteBread-onlycurrentFRM220-1000EAS/X RMON UTP 4 Transceiver/Receiver 128~255 Octets.
1.3.6.1.4.1.4756.20.302.40.1.348Columnf1000EASXUTP4256OctetsRemoteBread-onlycurrentFRM220-1000EAS/X RMON UTP 4 Transceiver/Receiver 256~511 Octets.
1.3.6.1.4.1.4756.20.302.40.1.349Columnf1000EASXUTP4512OctetsRemoteBread-onlycurrentFRM220-1000EAS/X RMON UTP 4 Transceiver/Receiver 512~1023 Octets.
1.3.6.1.4.1.4756.20.302.40.1.350Columnf1000EASXUTP41024OctetsRemoteBread-onlycurrentFRM220-1000EAS/X RMON UTP 4 Transceiver/Receiver 1024~Max Octets.
1.3.6.1.4.1.4756.20.310Nodef100mLocalCards
1.3.6.1.4.1.4756.20.310.20Tablef100mLocalTablenot-accessiblecurrentA list of local FRM220-F100M series card entries. The number of entries is f100m-No-L.
1.3.6.1.4.1.4756.20.310.20.1Rowf100mLocalEntrynot-accessiblecurrentAn entry containing management information applicable to a particular local FRM220-F100M series card.
1.3.6.1.4.1.4756.20.310.20.1.1Columnf100mChassisIndexLocalread-onlycurrentA unique value for each local card. It is the chassis location number.
1.3.6.1.4.1.4756.20.310.20.1.2Columnf100mSlotIndexLocalread-onlycurrentA unique value for each local card. It is the slot location number.
1.3.6.1.4.1.4756.20.310.20.1.3Columnf100mCardHWVerLocalread-onlycurrentLocal FRM220-F100M Series card hardware version x.xxx
1.3.6.1.4.1.4756.20.310.20.1.4Columnf100mCardFWVerLocalread-onlycurrentLocal FRM220-F100M Series card firmware version x.xxx
1.3.6.1.4.1.4756.20.310.20.1.5Columnf100mCardCPLDVerLocalread-onlycurrentLocal FRM220-F100M Series card CPLD version x.xxx
1.3.6.1.4.1.4756.20.310.20.1.6Columnf100mCardFPGAVerLocalread-onlycurrentLocal FRM220-F100M Series card FPGA version x.xxx
1.3.6.1.4.1.4756.20.310.20.1.7Columnf100mPortActiveLocalread-writecurrentLocal FRM220-F100M Series card active: 0:Disable 1:Enable
1.3.6.1.4.1.4756.20.310.20.1.8Columnf100mSettoDefaultLocalread-writecurrentLocal FRM220-F100M Series card set to default: 0:OFF 1:Action
1.3.6.1.4.1.4756.20.310.20.1.9Columnf100mPortResetLocalread-writecurrentLocal FRM220-F100M Series card portreset: 0:OFF 1:Action
1.3.6.1.4.1.4756.20.310.20.1.10Columnf100mModelLocalread-onlycurrentLocal FRM220-F100/1000MS Card Type: 0:100M 1:100MS 2:1000M 3:1000MS
1.3.6.1.4.1.4756.20.310.20.1.11Columnf100mFxLinkLocalread-onlycurrentLocal FRM220-F100M fiber link status: 0:Down 1:up
1.3.6.1.4.1.4756.20.310.20.1.12Columnf100mFxActiveLocalread-writecurrentLocal FRM220-F100M fiber active: 0:Disable 1:Enable
1.3.6.1.4.1.4756.20.310.20.1.13Columnf100mFxNegoLocalread-writecurrentLocal FRM220-F100M fiber negotiation: 0:Manual 1:Auto
1.3.6.1.4.1.4756.20.310.20.1.14Columnf100mFxSpeedLocalread-writecurrentLocal FRM220-F100M fiber speed: 0:100M 1:1000M
1.3.6.1.4.1.4756.20.310.20.1.15Columnf100mFxSpeedSTSLocalread-onlycurrentLocal FRM220-F100M loopback mode: 0:100M 1:1000M
1.3.6.1.4.1.4756.20.310.20.1.16Columnf100mFxManagementLocalread-writecurrentLocal FRM220-F100M fiber management: 0:Disalbe 1:Enable
1.3.6.1.4.1.4756.20.310.20.1.17Columnf100mFxFlowCnlSLocalread-writecurrentLocal FRM220-F100M fiber flow control: 0:Disalbe 1:Enable
1.3.6.1.4.1.4756.20.310.20.1.18Columnf100mFxIRLimiteLocalread-writecurrentLocal FRM220-F100M fiber IRL limit: 0:Disalbe 1:Enable
1.3.6.1.4.1.4756.20.310.20.1.19Columnf100mFxIRLLocalread-writecurrentLocal FRM220-F100M fiber IRL index N * 64K
1.3.6.1.4.1.4756.20.310.20.1.20Columnf100mFxERLimiteLocalread-writecurrentLocal FRM220-F100M fiber ERL limite: 0:Disalbe 1:Enable
1.3.6.1.4.1.4756.20.310.20.1.21Columnf100mFxERLLocalread-writecurrentLocal FRM220-F100M fiber ERL index N * 64K
1.3.6.1.4.1.4756.20.310.20.1.22Columnf100mUtpActiveLocalread-writecurrentLocal FRM220-F100M UTP active: 0:Disable 1:Enable
1.3.6.1.4.1.4756.20.310.20.1.23Columnf100mUtpLinkLocalread-onlycurrentLocal FRM220-F100M UTP link: 0:Down 1:Up
1.3.6.1.4.1.4756.20.310.20.1.24Columnf100mUtpNegoLocalread-writecurrentLocal FRM220-F100M UTP negotiation: 0:Manual 1:Auto
1.3.6.1.4.1.4756.20.310.20.1.25Columnf100mUtpSpeedLocalread-writecurrentLocal FRM220-F100M UTP speed: 0:10M 1:100M 2:1000M
1.3.6.1.4.1.4756.20.310.20.1.26Columnf100mUtpDuplexLocalread-writecurrentLocal FRM220-F100M UTP duplex: 0:Half 1:Full
1.3.6.1.4.1.4756.20.310.20.1.27Columnf100mUtpSpeedSTSLocalread-onlycurrentLocal FRM220-F100M UTP speed status: 0:10M 1:100M 2:1000M
1.3.6.1.4.1.4756.20.310.20.1.28Columnf100mUtpDuplexSTSLocalread-onlycurrentLocal FRM220-F100M UTP duplex status: 0:Half 1:Full
1.3.6.1.4.1.4756.20.310.20.1.29Columnf100mUtpFlowCnlLocalread-writecurrentLocal FRM220-F100M UTP flow control: 0:Disable 1:Enable
1.3.6.1.4.1.4756.20.310.20.1.30Columnf100mUtpIRLimiteLocalread-writecurrentLocal FRM220-F100M UTP IRL limit: 0:Disable 1:Enable
1.3.6.1.4.1.4756.20.310.20.1.31Columnf100mUtpIRLLocalread-writecurrentLocal FRM220-F100M UTP IRL index N * 64K
1.3.6.1.4.1.4756.20.310.20.1.32Columnf100mUtpERLimiteLocalread-writecurrentLocal FRM220-F100M UTP ERL limit: 0:Disable 1:Enable
1.3.6.1.4.1.4756.20.310.20.1.33Columnf100mUtpERLLocalread-writecurrentLocal FRM220-F100M UTP ERL index N * 64K
1.3.6.1.4.1.4756.20.310.20.1.34Columnf100mIpAddrLocalread-writecurrentLocal FRM220-F100M IP address
1.3.6.1.4.1.4756.20.310.20.1.35Columnf100mNetmaskLocalread-writecurrentLocal FRM220-F100M Netmask
1.3.6.1.4.1.4756.20.310.20.1.36Columnf100mGatewayLocalread-writecurrentLocal FRM220-F100M Gateway
1.3.6.1.4.1.4756.20.310.20.1.37Columnf100mAlsModeLocalread-writecurrentLocal FRM220-F100M Auto Laser Shut Down: 0:Disable 1:Enable
1.3.6.1.4.1.4756.20.310.20.1.38Columnf100mLfpModeLocalread-writecurrentLocal FRM220-F100M Link fault pass through: 0:Disable 1:Enable
1.3.6.1.4.1.4756.20.310.20.1.39Columnf100mDHCPLocalread-writecurrentLocal FRM220-F100M DHCP: 0:Disable 1:Enable
1.3.6.1.4.1.4756.20.310.20.1.40Columnf100mRemotePWRLocalread-onlycurrentLocal FRM220-F100M remote power: 0:Ok 1:Abnormal
1.3.6.1.4.1.4756.20.310.20.1.41Columnf100mJumboFrameLocalread-writecurrentLocal FRM220-F100M jumbo frame: 0:Disable 1:Enable
1.3.6.1.4.1.4756.20.310.20.1.42Columnf100mCrcLocalread-writecurrentLocal FRM220-F100M crc: 0:OFF 1:ON
1.3.6.1.4.1.4756.20.310.20.1.43Columnf100mPauseFrameLocalread-writecurrentLocal FRM220-F100M pause frame: 0:Disable 1:Enable
1.3.6.1.4.1.4756.20.310.20.1.44Columnf100mQosLocalread-writecurrentLocal FRM220-F100M pause frame: 0:Disable 1:Enable
1.3.6.1.4.1.4756.20.310.20.1.45Columnf100mBsFilterLocalread-writecurrentLocal FRM220-F100M Brosdcast Storm Filter : 0:Disable 1:Enalbe
1.3.6.1.4.1.4756.20.310.20.1.46Columnf100mMsFilterLocalread-writecurrentLocal FRM220-F100M Multicast Storm Filter: 0:Disable 1:Enable
1.3.6.1.4.1.4756.20.310.20.1.47Columnf100mUnDaFilterLocalread-writecurrentLocal FRM220-F100M Unknown DA Unicast Storm Filter: 0:Disable 1:Enable
1.3.6.1.4.1.4756.20.310.20.1.48Columnf100mTpVLANNBLocalread-writecurrentLocal FRM220-F100M Tp VLAN number:
1.3.6.1.4.1.4756.20.310.20.1.49Columnf100mTpFrameGressLocalread-writecurrentLocal FRM220-F100M TP Frame Egress Type: 0:Replace Tag 1:Remove Tag 2:Add Tag 3:Don't Touch Tag
1.3.6.1.4.1.4756.20.310.20.1.50Columnf100mFxVLANNBLocalread-writecurrentLocal FRM220-F100M Fx VLAN number:
1.3.6.1.4.1.4756.20.310.20.1.51Columnf100mFxFrameGressLocalread-writecurrentLocal FRM220-F100M Fx Frame Egress Type: 0:Replace Tag 1:Remove Tag 2:Add Tag 3:Don't Touch Tag
1.3.6.1.4.1.4756.20.310.20.1.52Columnf100mCpuVLANNBLocalread-writecurrentLocal FRM220-F100M Cpu VLAN number:
1.3.6.1.4.1.4756.20.310.20.1.53Columnf100mCpuFrameGressLocalread-writecurrentLocal FRM220-F100M Cpu Frame Egress Type: 0:Replace Tag 1:Remove Tag 2:Add Tag 3:Don't Touch Tag
1.3.6.1.4.1.4756.20.310.20.1.54Columnf100mVLANGpLocalread-writecurrentLocal FRM220-F100M VLAN Group : 0:Disable 1:Enalbe
1.3.6.1.4.1.4756.20.310.20.1.55Columnf100mTpMember0Localread-writecurrentLocal FRM220-F100M Tp Member 0: 0:Disalbe 1:Enable
1.3.6.1.4.1.4756.20.310.20.1.56Columnf100mTpMember1Localread-writecurrentLocal FRM220-F100M Tp Member 1: 0:Disalbe 1:Enable
1.3.6.1.4.1.4756.20.310.20.1.57Columnf100mTpMember2Localread-writecurrentLocal FRM220-F100M Tp Member 2: 0:Disalbe 1:Enable
1.3.6.1.4.1.4756.20.310.20.1.58Columnf100mTpMember3Localread-writecurrentLocal FRM220-F100M Tp Member 3: 0:Disalbe 1:Enable
1.3.6.1.4.1.4756.20.310.20.1.59Columnf100mTpMember4Localread-writecurrentLocal FRM220-F100M Tp Member 4: 0:Disalbe 1:Enable
1.3.6.1.4.1.4756.20.310.20.1.60Columnf100mTpMember5Localread-writecurrentLocal FRM220-F100M Tp Member 5: 0:Disalbe 1:Enable
1.3.6.1.4.1.4756.20.310.20.1.61Columnf100mTpMember6Localread-writecurrentLocal FRM220-F100M Tp Member 6: 0:Disalbe 1:Enable
1.3.6.1.4.1.4756.20.310.20.1.62Columnf100mTpMember7Localread-writecurrentLocal FRM220-F100M Tp Member 7: 0:Disalbe 1:Enable
1.3.6.1.4.1.4756.20.310.20.1.63Columnf100mTpMember8Localread-writecurrentLocal FRM220-F100M Tp Member 8: 0:Disalbe 1:Enable
1.3.6.1.4.1.4756.20.310.20.1.64Columnf100mTpMember9Localread-writecurrentLocal FRM220-F100M Tp Member 9: 0:Disalbe 1:Enable
1.3.6.1.4.1.4756.20.310.20.1.65Columnf100mTpMember10Localread-writecurrentLocal FRM220-F100M Tp Member 10: 0:Disalbe 1:Enable
1.3.6.1.4.1.4756.20.310.20.1.66Columnf100mTpMember11Localread-writecurrentLocal FRM220-F100M Tp Member 11: 0:Disalbe 1:Enable
1.3.6.1.4.1.4756.20.310.20.1.67Columnf100mTpMember12Localread-writecurrentLocal FRM220-F100M Tp Member 12: 0:Disalbe 1:Enable
1.3.6.1.4.1.4756.20.310.20.1.68Columnf100mTpMember13Localread-writecurrentLocal FRM220-F100M Tp Member 13: 0:Disalbe 1:Enable
1.3.6.1.4.1.4756.20.310.20.1.69Columnf100mTpMember14Localread-writecurrentLocal FRM220-F100M Tp Member 14: 0:Disalbe 1:Enable
1.3.6.1.4.1.4756.20.310.20.1.70Columnf100mTpMember15Localread-writecurrentLocal FRM220-F100M Tp Member 15: 0:Disalbe 1:Enable
1.3.6.1.4.1.4756.20.310.20.1.71Columnf100mFxMember0Localread-writecurrentLocal FRM220-F100M Fx Member 0: 0:Disalbe 1:Enable
1.3.6.1.4.1.4756.20.310.20.1.72Columnf100mFxMember1Localread-writecurrentLocal FRM220-F100M Fx Member 1: 0:Disalbe 1:Enable
1.3.6.1.4.1.4756.20.310.20.1.73Columnf100mFxMember2Localread-writecurrentLocal FRM220-F100M Fx Member 2: 0:Disalbe 1:Enable
1.3.6.1.4.1.4756.20.310.20.1.74Columnf100mFxMember3Localread-writecurrentLocal FRM220-F100M Fx Member 3: 0:Disalbe 1:Enable
1.3.6.1.4.1.4756.20.310.20.1.75Columnf100mFxMember4Localread-writecurrentLocal FRM220-F100M Fx Member 4: 0:Disalbe 1:Enable
1.3.6.1.4.1.4756.20.310.20.1.76Columnf100mFxMember5Localread-writecurrentLocal FRM220-F100M Fx Member 5: 0:Disalbe 1:Enable
1.3.6.1.4.1.4756.20.310.20.1.77Columnf100mFxMember6Localread-writecurrentLocal FRM220-F100M Fx Member 6: 0:Disalbe 1:Enable
1.3.6.1.4.1.4756.20.310.20.1.78Columnf100mFxMember7Localread-writecurrentLocal FRM220-F100M Fx Member 7: 0:Disalbe 1:Enable
1.3.6.1.4.1.4756.20.310.20.1.79Columnf100mFxMember8Localread-writecurrentLocal FRM220-F100M Fx Member 8: 0:Disalbe 1:Enable
1.3.6.1.4.1.4756.20.310.20.1.80Columnf100mFxMember9Localread-writecurrentLocal FRM220-F100M Fx Member 9: 0:Disalbe 1:Enable
1.3.6.1.4.1.4756.20.310.20.1.81Columnf100mFxMember10Localread-writecurrentLocal FRM220-F100M Fx Member 10: 0:Disalbe 1:Enable
1.3.6.1.4.1.4756.20.310.20.1.82Columnf100mFxMember11Localread-writecurrentLocal FRM220-F100M Fx Member 11: 0:Disalbe 1:Enable
1.3.6.1.4.1.4756.20.310.20.1.83Columnf100mFxMember12Localread-writecurrentLocal FRM220-F100M Fx Member 12: 0:Disalbe 1:Enable
1.3.6.1.4.1.4756.20.310.20.1.84Columnf100mFxMember13Localread-writecurrentLocal FRM220-F100M Fx Member 13: 0:Disalbe 1:Enable
1.3.6.1.4.1.4756.20.310.20.1.85Columnf100mFxMember14Localread-writecurrentLocal FRM220-F100M Fx Member 14: 0:Disalbe 1:Enable
1.3.6.1.4.1.4756.20.310.20.1.86Columnf100mFxMember15Localread-writecurrentLocal FRM220-F100M Fx Member 15: 0:Disalbe 1:Enable
1.3.6.1.4.1.4756.20.310.20.1.87Columnf100mCpuMember0Localread-writecurrentLocal FRM220-F100M Cpu Member 0: 0:Disalbe 1:Enable
1.3.6.1.4.1.4756.20.310.20.1.88Columnf100mCpuMember1Localread-writecurrentLocal FRM220-F100M Cpu Member 1: 0:Disalbe 1:Enable
1.3.6.1.4.1.4756.20.310.20.1.89Columnf100mCpuMember2Localread-writecurrentLocal FRM220-F100M Cpu Member 2: 0:Disalbe 1:Enable
1.3.6.1.4.1.4756.20.310.20.1.90Columnf100mCpuMember3Localread-writecurrentLocal FRM220-F100M Cpu Member 3: 0:Disalbe 1:Enable
1.3.6.1.4.1.4756.20.310.20.1.91Columnf100mCpuMember4Localread-writecurrentLocal FRM220-F100M Cpu Member 4: 0:Disalbe 1:Enable
1.3.6.1.4.1.4756.20.310.20.1.92Columnf100mCpuMember5Localread-writecurrentLocal FRM220-F100M Cpu Member 5: 0:Disalbe 1:Enable
1.3.6.1.4.1.4756.20.310.20.1.93Columnf100mCpuMember6Localread-writecurrentLocal FRM220-F100M Cpu Member 6: 0:Disalbe 1:Enable
1.3.6.1.4.1.4756.20.310.20.1.94Columnf100mCpuMember7Localread-writecurrentLocal FRM220-F100M Cpu Member 7: 0:Disalbe 1:Enable
1.3.6.1.4.1.4756.20.310.20.1.95Columnf100mCpuMember8Localread-writecurrentLocal FRM220-F100M Cpu Member 8: 0:Disalbe 1:Enable
1.3.6.1.4.1.4756.20.310.20.1.96Columnf100mCpuMember9Localread-writecurrentLocal FRM220-F100M Cpu Member 9: 0:Disalbe 1:Enable
1.3.6.1.4.1.4756.20.310.20.1.97Columnf100mCpuMember10Localread-writecurrentLocal FRM220-F100M Cpu Member 10: 0:Disalbe 1:Enable
1.3.6.1.4.1.4756.20.310.20.1.98Columnf100mCpuMember11Localread-writecurrentLocal FRM220-F100M Cpu Member 11: 0:Disalbe 1:Enable
1.3.6.1.4.1.4756.20.310.20.1.99Columnf100mCpuMember12Localread-writecurrentLocal FRM220-F100M Cpu Member 12: 0:Disalbe 1:Enable
1.3.6.1.4.1.4756.20.310.20.1.100Columnf100mCpuMember13Localread-writecurrentLocal FRM220-F100M Cpu Member 13: 0:Disalbe 1:Enable
1.3.6.1.4.1.4756.20.310.20.1.101Columnf100mCpuMember14Localread-writecurrentLocal FRM220-F100M Cpu Member 14: 0:Disalbe 1:Enable
1.3.6.1.4.1.4756.20.310.20.1.102Columnf100mCpuMember15Localread-writecurrentLocal FRM220-F100M Cpu Member 15: 0:Disalbe 1:Enable
1.3.6.1.4.1.4756.20.310.20.1.103Columnf100mPVID0Localread-writecurrentLocal FRM220-F100M Port 0 VID :
1.3.6.1.4.1.4756.20.310.20.1.104Columnf100mPVID1Localread-writecurrentLocal FRM220-F100M Port 1 VID :
1.3.6.1.4.1.4756.20.310.20.1.105Columnf100mPVID2Localread-writecurrentLocal FRM220-F100M Port 2 VID :
1.3.6.1.4.1.4756.20.310.20.1.106Columnf100mPVID3Localread-writecurrentLocal FRM220-F100M Port 3 VID :
1.3.6.1.4.1.4756.20.310.20.1.107Columnf100mPVID4Localread-writecurrentLocal FRM220-F100M Port 4 VID :
1.3.6.1.4.1.4756.20.310.20.1.108Columnf100mPVID5Localread-writecurrentLocal FRM220-F100M Port 5 VID :
1.3.6.1.4.1.4756.20.310.20.1.109Columnf100mPVID6Localread-writecurrentLocal FRM220-F100M Port 6 VID :
1.3.6.1.4.1.4756.20.310.20.1.110Columnf100mPVID7Localread-writecurrentLocal FRM220-F100M Port 7 VID :
1.3.6.1.4.1.4756.20.310.20.1.111Columnf100mPVID8Localread-writecurrentLocal FRM220-F100M Port 8 VID :
1.3.6.1.4.1.4756.20.310.20.1.112Columnf100mPVID9Localread-writecurrentLocal FRM220-F100M Port 9 VID :
1.3.6.1.4.1.4756.20.310.20.1.113Columnf100mPVID10Localread-writecurrentLocal FRM220-F100M Port 10 VID :
1.3.6.1.4.1.4756.20.310.20.1.114Columnf100mPVID11Localread-writecurrentLocal FRM220-F100M Port 11 VID :
1.3.6.1.4.1.4756.20.310.20.1.115Columnf100mPVID12Localread-writecurrentLocal FRM220-F100M Port 12 VID :
1.3.6.1.4.1.4756.20.310.20.1.116Columnf100mPVID13Localread-writecurrentLocal FRM220-F100M Port 13 VID :
1.3.6.1.4.1.4756.20.310.20.1.117Columnf100mPVID14Localread-writecurrentLocal FRM220-F100M Port 14 VID :
1.3.6.1.4.1.4756.20.310.20.1.118Columnf100mPVID15Localread-writecurrentLocal FRM220-F100M Port 15 VID :
1.3.6.1.4.1.4756.20.310.20.1.119Columnf100mDoubleVLANLocalread-writecurrentLocal FRM220-F100M Double VLAN: 0:Disable 1:Enable
1.3.6.1.4.1.4756.20.310.20.1.120Columnf100mDoubleVLANTagPriorityLocalread-writecurrentLocal FRM220-F100M Double VLAN Tag Priority : 0:Internal 1:Remark
1.3.6.1.4.1.4756.20.310.20.1.121Columnf100mDoubleVLANDirectionLocalread-writecurrentLocal FRM220-F100M Double VLAN Direction : 0:TP add,FX Remove 1:FX add,TP Remove
1.3.6.1.4.1.4756.20.310.20.1.122Columnf100mDoubleVLANTagTypeLocalread-onlycurrentLocal FRM220-F100M Tag Type (HEX) :
1.3.6.1.4.1.4756.20.310.20.1.123Columnf100mDoubleVLANVIDLocalread-writecurrentLocal FRM220-F100M Double VLAN VID :
1.3.6.1.4.1.4756.20.310.20.1.124Columnf100mFxDDLocalread-onlycurrentLocal device card fiber Digital Diagnostic function: 0:No 1:Yes
1.3.6.1.4.1.4756.20.310.20.1.125Columnf100mDDVendorLocalread-onlycurrentLocal device card fiber D/D information: Vendor name
1.3.6.1.4.1.4756.20.310.20.1.126Columnf100mDDPartNoLocalread-onlycurrentLocal device card fiber D/D information: Vendor part number
1.3.6.1.4.1.4756.20.310.20.1.127Columnf100mDDFiberTypeLocalread-onlycurrentLocal device card fiber D/D information: Fiber Type
1.3.6.1.4.1.4756.20.310.20.1.128Columnf100mDDWaveLenLocalread-onlycurrentLocal device card fiber D/D information: Wave length
1.3.6.1.4.1.4756.20.310.20.1.129Columnf100mDDWaveLen2Localread-onlycurrentLocal device card fiber D/D information: Wave length 2
1.3.6.1.4.1.4756.20.310.20.1.130Columnf100mDDLinkLenLocalread-onlycurrentLocal device card fiber D/D information: Link length
1.3.6.1.4.1.4756.20.310.20.1.131Columnf100mDDLenUnitLocalread-onlycurrentLocal device card fiber D/D information: Length Unit
1.3.6.1.4.1.4756.20.310.20.1.132Columnf100mDDStatusLocalread-onlycurrentLocal device card fiber D/D information: Status Support
1.3.6.1.4.1.4756.20.310.20.1.133Columnf100mDDRxSensLocalread-onlycurrentLocal device card fiber D/D information: Rx Sensitivity
1.3.6.1.4.1.4756.20.310.20.1.134Columnf100mDDTxPWRLocalread-onlycurrentLocal device card fiber D/D information: Tx power
1.3.6.1.4.1.4756.20.310.20.1.135Columnf100mDDRxPWRLocalread-onlycurrentLocal device card fiber D/D information: Rx power
1.3.6.1.4.1.4756.20.310.20.1.136Columnf100mDDTempLocalread-onlycurrentLocal device card fiber D/D information: Temperature in degree C
1.3.6.1.4.1.4756.20.310.20.1.137Columnf100mDDPWRMarginLocalread-onlycurrentLocal device card fiber D/D information: Power margin
1.3.6.1.4.1.4756.20.310.20.1.138Columnf100mLBStartLocalread-writecurrentLocal device card Loop back test : 1:Off 2:Action
1.3.6.1.4.1.4756.20.310.20.1.139Columnf100mLBStartStatusLocalread-onlycurrentLocal device card Loop back test status : 1:Normal 2:Ok 3:Fail
1.3.6.1.4.1.4756.20.311Nodef100mRemoteCards
1.3.6.1.4.1.4756.20.311.20Tablef100mRemoteTablenot-accessiblecurrentA list of local FRM220-F100M series card entries. The number of entries is f100m-No-R.
1.3.6.1.4.1.4756.20.311.20.1Rowf100mRemoteEntrynot-accessiblecurrentAn entry containing management information applicable to a particular remote FRM220-F100M series card.
1.3.6.1.4.1.4756.20.311.20.1.1Columnf100mChassisIndexRemoteread-onlycurrentA unique value for each local card. It is the chassis location number.
1.3.6.1.4.1.4756.20.311.20.1.2Columnf100mSlotIndexRemoteread-onlycurrentA unique value for each local card. It is the slot location number.
1.3.6.1.4.1.4756.20.311.20.1.3Columnf100mCardHWVerRemoteread-onlycurrentRemote FRM220-F100M Series card hardware version x.xxx
1.3.6.1.4.1.4756.20.311.20.1.4Columnf100mCardFWVerRemoteread-onlycurrentRemote FRM220-F100M Series card firmware version x.xxx
1.3.6.1.4.1.4756.20.311.20.1.5Columnf100mCardCPLDVerRemoteread-onlycurrentRemote FRM220-F100M Series card CPLD version x.xxx
1.3.6.1.4.1.4756.20.311.20.1.6Columnf100mCardFPGAVerRemoteread-onlycurrentRemote FRM220-F100M Series card FPGA version x.xxx
1.3.6.1.4.1.4756.20.311.20.1.7Columnf100mSettoDefaultRemoteread-writecurrentRemote FRM220-F100M Series card set to default: 0:OFF 1:Action
1.3.6.1.4.1.4756.20.311.20.1.8Columnf100mPortResetRemoteread-writecurrentRemote FRM220-F100M Series card portreset: 0:OFF 1:Action
1.3.6.1.4.1.4756.20.311.20.1.9Columnf100mModelRemoteread-onlycurrentRemote FRM220-F100/1000MS Card Type: 0:100M 1:100MS 2:1000M 3:1000MS 4:FMC-100M 5:FMC-100MS 6:FMC-1000M 7:FMC-1000MS 8:FTH4-100M 9:FTH4-100MS 10:FTH4-1000M 11:…
1.3.6.1.4.1.4756.20.311.20.1.10Columnf100mFxLinkRemoteread-onlycurrentRemote FRM220-F100M fiber link status: 0:Down 1:up
1.3.6.1.4.1.4756.20.311.20.1.11Columnf100mFxNegoRemoteread-writecurrentRemote FRM220-F100M fiber negotiation: 0:Manual 1:Auto
1.3.6.1.4.1.4756.20.311.20.1.12Columnf100mFxSpeedRemoteread-writecurrentRemote FRM220-F100M fiber speed: 0:100M 1:1000M
1.3.6.1.4.1.4756.20.311.20.1.13Columnf100mFxSpeedSTSRemoteread-onlycurrentRemote FRM220-F100M loopback mode: 0:100M 1:1000M
1.3.6.1.4.1.4756.20.311.20.1.14Columnf100mFxManagementRemoteread-writecurrentRemote FRM220-F100M fiber management: 0:Disalbe 1:Enable
1.3.6.1.4.1.4756.20.311.20.1.15Columnf100mFxFlowCnlSRemoteread-writecurrentRemote FRM220-F100M fiber flow control: 0:Disalbe 1:Enable
1.3.6.1.4.1.4756.20.311.20.1.16Columnf100mFxIRLimiteRemoteread-writecurrentRemote FRM220-F100M fiber IRL limit: 0:Disalbe 1:Enable
1.3.6.1.4.1.4756.20.311.20.1.17Columnf100mFxIRLRemoteread-writecurrentRemote FRM220-F100M fiber IRL index N * 64K
1.3.6.1.4.1.4756.20.311.20.1.18Columnf100mFxERLimiteRemoteread-writecurrentRemote FRM220-F100M fiber ERL limit: 0:Disalbe 1:Enable
1.3.6.1.4.1.4756.20.311.20.1.19Columnf100mFxERLRemoteread-writecurrentRemote FRM220-F100M fiber ERL index N * 64K
1.3.6.1.4.1.4756.20.311.20.1.20Columnf100mUtpActiveRemoteread-writecurrentRemote FRM220-F100M UTP active: 0:Disable 1:Enable
1.3.6.1.4.1.4756.20.311.20.1.21Columnf100mUtpLinkRemoteread-onlycurrentRemote FRM220-F100M UTP link: 0:Down 1:Up
1.3.6.1.4.1.4756.20.311.20.1.22Columnf100mUtpNegoRemoteread-writecurrentRemote FRM220-F100M UTP negotiation: 0:Manual 1:Auto
1.3.6.1.4.1.4756.20.311.20.1.23Columnf100mUtpSpeedRemoteread-writecurrentRemote FRM220-F100M UTP speed: 0:10M 1:100M 2:1000M
1.3.6.1.4.1.4756.20.311.20.1.24Columnf100mUtpDuplexRemoteread-writecurrentRemote FRM220-F100M UTP duplex: 0:Half 1:Full
1.3.6.1.4.1.4756.20.311.20.1.25Columnf100mUtpSpeedSTSRemoteread-onlycurrentRemote FRM220-F100M UTP speed status: 0:10M 1:100M 2:1000M
1.3.6.1.4.1.4756.20.311.20.1.26Columnf100mUtpDuplexSTSRemoteread-onlycurrentRemote FRM220-F100M UTP duplex status: 0:Half 1:Full
1.3.6.1.4.1.4756.20.311.20.1.27Columnf100mUtpFlowCnlRemoteread-writecurrentRemote FRM220-F100M UTP flow control: 0:Disable 1:Enable
1.3.6.1.4.1.4756.20.311.20.1.28Columnf100mUtpIRLimiteRemoteread-writecurrentRemote FRM220-F100M UTP IRL limit: 0:Disable 1:Enable
1.3.6.1.4.1.4756.20.311.20.1.29Columnf100mUtpIRLRemoteread-writecurrentRemote FRM220-F100M UTP IRL index N * 64K
1.3.6.1.4.1.4756.20.311.20.1.30Columnf100mUtpERLimiteRemoteread-writecurrentRemote FRM220-F100M UTP ERL limit: 0:Disable 1:Enable
1.3.6.1.4.1.4756.20.311.20.1.31Columnf100mUtpERLRemoteread-writecurrentRemote FRM220-F100M UTP ERL index N * 64K
1.3.6.1.4.1.4756.20.311.20.1.32Columnf100mIpAddrRemoteread-writecurrentRemote FRM220-F100M IP address
1.3.6.1.4.1.4756.20.311.20.1.33Columnf100mNetmaskRemoteread-writecurrentRemote FRM220-F100M Netmask
1.3.6.1.4.1.4756.20.311.20.1.34Columnf100mGatewayRemoteread-writecurrentRemote FRM220-F100M Gateway
1.3.6.1.4.1.4756.20.311.20.1.35Columnf100mAlsModeRemoteread-writecurrentRemote FRM220-F100M Auto Laser Shut Down: 0:Disable 1:Enable
1.3.6.1.4.1.4756.20.311.20.1.36Columnf100mLfpModeRemoteread-writecurrentRemote FRM220-F100M Link fault pass through: 0:Disable 1:Enable
1.3.6.1.4.1.4756.20.311.20.1.37Columnf100mDHCPRemoteread-writecurrentRemote FRM220-F100M DHCP: 0:Disable 1:Enable
1.3.6.1.4.1.4756.20.311.20.1.38Columnf100mRemotePWRRemoteread-onlycurrentRemote FRM220-F100M remote power: 0:Ok 1:Abnormal
1.3.6.1.4.1.4756.20.311.20.1.39Columnf100mJumboFrameRemoteread-writecurrentRemote FRM220-F100M jumbo frame: 0:Disable 1:Enable
1.3.6.1.4.1.4756.20.311.20.1.40Columnf100mCrcRemoteread-writecurrentRemote FRM220-F100M crc: 0:OFF 1:ON
1.3.6.1.4.1.4756.20.311.20.1.41Columnf100mPauseFrameRemoteread-writecurrentRemote FRM220-F100M pause frame: 0:Disable 1:Enable
1.3.6.1.4.1.4756.20.311.20.1.42Columnf100mQosRemoteread-writecurrentRemote FRM220-F100M pause frame: 0:Disable 1:Enable
1.3.6.1.4.1.4756.20.311.20.1.43Columnf100mBsFilterRemoteread-writecurrentRemote FRM220-F100M Brosdcast Storm Filter : 0:Disable 1:Enalbe
1.3.6.1.4.1.4756.20.311.20.1.44Columnf100mMsFilterRemoteread-writecurrentRemote FRM220-F100M Multicast Storm Filter: 0:Disable 1:Enable
1.3.6.1.4.1.4756.20.311.20.1.45Columnf100mUnDaFilterRemoteread-writecurrentRemote FRM220-F100M Unknown DA Unicast Storm Filter: 0:Disable 1:Enable
1.3.6.1.4.1.4756.20.311.20.1.46Columnf100mTpVLANNBRemoteread-writecurrentRemote FRM220-F100M Tp VLAN number:
1.3.6.1.4.1.4756.20.311.20.1.47Columnf100mTpFrameGressRemoteread-writecurrentRemote FRM220-F100M TP Frame Egress Type: 0:Replace Tag 1:Remove Tag 2:Add Tag 3:Don't Touch Tag
1.3.6.1.4.1.4756.20.311.20.1.48Columnf100mFxVLANNBRemoteread-writecurrentRemote FRM220-F100M Fx VLAN number:
1.3.6.1.4.1.4756.20.311.20.1.49Columnf100mFxFrameGressRemoteread-writecurrentRemote FRM220-F100M Fx Frame Egress Type: 0:Replace Tag 1:Remove Tag 2:Add Tag 3:Don't Touch Tag
1.3.6.1.4.1.4756.20.311.20.1.50Columnf100mCpuVLANNBRemoteread-writecurrentRemote FRM220-F100M Cpu VLAN number:
1.3.6.1.4.1.4756.20.311.20.1.51Columnf100mCpuFrameGressRemoteread-writecurrentRemote FRM220-F100M Cpu Frame Egress Type: 0:Replace Tag 1:Remove Tag 2:Add Tag 3:Don't Touch Tag
1.3.6.1.4.1.4756.20.311.20.1.52Columnf100mVLANGpRemoteread-writecurrentRemote FRM220-F100M VLAN Group : 0:Disable 1:Enalbe
1.3.6.1.4.1.4756.20.311.20.1.53Columnf100mTpMember0Remoteread-writecurrentRemote FRM220-F100M Tp Member 0: 0:Disalbe 1:Enable
1.3.6.1.4.1.4756.20.311.20.1.54Columnf100mTpMember1Remoteread-writecurrentRemote FRM220-F100M Tp Member 1: 0:Disalbe 1:Enable
1.3.6.1.4.1.4756.20.311.20.1.55Columnf100mTpMember2Remoteread-writecurrentRemote FRM220-F100M Tp Member 2: 0:Disalbe 1:Enable
1.3.6.1.4.1.4756.20.311.20.1.56Columnf100mTpMember3Remoteread-writecurrentRemote FRM220-F100M Tp Member 3: 0:Disalbe 1:Enable
1.3.6.1.4.1.4756.20.311.20.1.57Columnf100mTpMember4Remoteread-writecurrentRemote FRM220-F100M Tp Member 4: 0:Disalbe 1:Enable
1.3.6.1.4.1.4756.20.311.20.1.58Columnf100mTpMember5Remoteread-writecurrentRemote FRM220-F100M Tp Member 5: 0:Disalbe 1:Enable
1.3.6.1.4.1.4756.20.311.20.1.59Columnf100mTpMember6Remoteread-writecurrentRemote FRM220-F100M Tp Member 6: 0:Disalbe 1:Enable
1.3.6.1.4.1.4756.20.311.20.1.60Columnf100mTpMember7Remoteread-writecurrentRemote FRM220-F100M Tp Member 7: 0:Disalbe 1:Enable
1.3.6.1.4.1.4756.20.311.20.1.61Columnf100mTpMember8Remoteread-writecurrentRemote FRM220-F100M Tp Member 8: 0:Disalbe 1:Enable
1.3.6.1.4.1.4756.20.311.20.1.62Columnf100mTpMember9Remoteread-writecurrentRemote FRM220-F100M Tp Member 9: 0:Disalbe 1:Enable
1.3.6.1.4.1.4756.20.311.20.1.63Columnf100mTpMember10Remoteread-writecurrentRemote FRM220-F100M Tp Member 10: 0:Disalbe 1:Enable
1.3.6.1.4.1.4756.20.311.20.1.64Columnf100mTpMember11Remoteread-writecurrentRemote FRM220-F100M Tp Member 11: 0:Disalbe 1:Enable
1.3.6.1.4.1.4756.20.311.20.1.65Columnf100mTpMember12Remoteread-writecurrentRemote FRM220-F100M Tp Member 12: 0:Disalbe 1:Enable
1.3.6.1.4.1.4756.20.311.20.1.66Columnf100mTpMember13Remoteread-writecurrentRemote FRM220-F100M Tp Member 13: 0:Disalbe 1:Enable
1.3.6.1.4.1.4756.20.311.20.1.67Columnf100mTpMember14Remoteread-writecurrentRemote FRM220-F100M Tp Member 14: 0:Disalbe 1:Enable
1.3.6.1.4.1.4756.20.311.20.1.68Columnf100mTpMember15Remoteread-writecurrentRemote FRM220-F100M Tp Member 15: 0:Disalbe 1:Enable
1.3.6.1.4.1.4756.20.311.20.1.69Columnf100mFxMember0Remoteread-writecurrentRemote FRM220-F100M Fx Member 0: 0:Disalbe 1:Enable
1.3.6.1.4.1.4756.20.311.20.1.70Columnf100mFxMember1Remoteread-writecurrentRemote FRM220-F100M Fx Member 1: 0:Disalbe 1:Enable
1.3.6.1.4.1.4756.20.311.20.1.71Columnf100mFxMember2Remoteread-writecurrentRemote FRM220-F100M Fx Member 2: 0:Disalbe 1:Enable
1.3.6.1.4.1.4756.20.311.20.1.72Columnf100mFxMember3Remoteread-writecurrentRemote FRM220-F100M Fx Member 3: 0:Disalbe 1:Enable
1.3.6.1.4.1.4756.20.311.20.1.73Columnf100mFxMember4Remoteread-writecurrentRemote FRM220-F100M Fx Member 4: 0:Disalbe 1:Enable
1.3.6.1.4.1.4756.20.311.20.1.74Columnf100mFxMember5Remoteread-writecurrentRemote FRM220-F100M Fx Member 5: 0:Disalbe 1:Enable
1.3.6.1.4.1.4756.20.311.20.1.75Columnf100mFxMember6Remoteread-writecurrentRemote FRM220-F100M Fx Member 6: 0:Disalbe 1:Enable
1.3.6.1.4.1.4756.20.311.20.1.76Columnf100mFxMember7Remoteread-writecurrentRemote FRM220-F100M Fx Member 7: 0:Disalbe 1:Enable
1.3.6.1.4.1.4756.20.311.20.1.77Columnf100mFxMember8Remoteread-writecurrentRemote FRM220-F100M Fx Member 8: 0:Disalbe 1:Enable
1.3.6.1.4.1.4756.20.311.20.1.78Columnf100mFxMember9Remoteread-writecurrentRemote FRM220-F100M Fx Member 9: 0:Disalbe 1:Enable
1.3.6.1.4.1.4756.20.311.20.1.79Columnf100mFxMember10Remoteread-writecurrentRemote FRM220-F100M Fx Member 10: 0:Disalbe 1:Enable
1.3.6.1.4.1.4756.20.311.20.1.80Columnf100mFxMember11Remoteread-writecurrentRemote FRM220-F100M Fx Member 11: 0:Disalbe 1:Enable
1.3.6.1.4.1.4756.20.311.20.1.81Columnf100mFxMember12Remoteread-writecurrentRemote FRM220-F100M Fx Member 12: 0:Disalbe 1:Enable
1.3.6.1.4.1.4756.20.311.20.1.82Columnf100mFxMember13Remoteread-writecurrentRemote FRM220-F100M Fx Member 13: 0:Disalbe 1:Enable
1.3.6.1.4.1.4756.20.311.20.1.83Columnf100mFxMember14Remoteread-writecurrentRemote FRM220-F100M Fx Member 14: 0:Disalbe 1:Enable
1.3.6.1.4.1.4756.20.311.20.1.84Columnf100mFxMember15Remoteread-writecurrentRemote FRM220-F100M Fx Member 15: 0:Disalbe 1:Enable
1.3.6.1.4.1.4756.20.311.20.1.85Columnf100mCpuMember0Remoteread-writecurrentRemote FRM220-F100M Cpu Member 0: 0:Disalbe 1:Enable
1.3.6.1.4.1.4756.20.311.20.1.86Columnf100mCpuMember1Remoteread-writecurrentRemote FRM220-F100M Cpu Member 1: 0:Disalbe 1:Enable
1.3.6.1.4.1.4756.20.311.20.1.87Columnf100mCpuMember2Remoteread-writecurrentRemote FRM220-F100M Cpu Member 2: 0:Disalbe 1:Enable
1.3.6.1.4.1.4756.20.311.20.1.88Columnf100mCpuMember3Remoteread-writecurrentRemote FRM220-F100M Cpu Member 3: 0:Disalbe 1:Enable
1.3.6.1.4.1.4756.20.311.20.1.89Columnf100mCpuMember4Remoteread-writecurrentRemote FRM220-F100M Cpu Member 4: 0:Disalbe 1:Enable
1.3.6.1.4.1.4756.20.311.20.1.90Columnf100mCpuMember5Remoteread-writecurrentRemote FRM220-F100M Cpu Member 5: 0:Disalbe 1:Enable
1.3.6.1.4.1.4756.20.311.20.1.91Columnf100mCpuMember6Remoteread-writecurrentRemote FRM220-F100M Cpu Member 6: 0:Disalbe 1:Enable
1.3.6.1.4.1.4756.20.311.20.1.92Columnf100mCpuMember7Remoteread-writecurrentRemote FRM220-F100M Cpu Member 7: 0:Disalbe 1:Enable
1.3.6.1.4.1.4756.20.311.20.1.93Columnf100mCpuMember8Remoteread-writecurrentRemote FRM220-F100M Cpu Member 8: 0:Disalbe 1:Enable
1.3.6.1.4.1.4756.20.311.20.1.94Columnf100mCpuMember9Remoteread-writecurrentRemote FRM220-F100M Cpu Member 9: 0:Disalbe 1:Enable
1.3.6.1.4.1.4756.20.311.20.1.95Columnf100mCpuMember10Remoteread-writecurrentRemote FRM220-F100M Cpu Member 10: 0:Disalbe 1:Enable
1.3.6.1.4.1.4756.20.311.20.1.96Columnf100mCpuMember11Remoteread-writecurrentRemote FRM220-F100M Cpu Member 11: 0:Disalbe 1:Enable
1.3.6.1.4.1.4756.20.311.20.1.97Columnf100mCpuMember12Remoteread-writecurrentRemote FRM220-F100M Cpu Member 12: 0:Disalbe 1:Enable
1.3.6.1.4.1.4756.20.311.20.1.98Columnf100mCpuMember13Remoteread-writecurrentRemote FRM220-F100M Cpu Member 13: 0:Disalbe 1:Enable
1.3.6.1.4.1.4756.20.311.20.1.99Columnf100mCpuMember14Remoteread-writecurrentRemote FRM220-F100M Cpu Member 14: 0:Disalbe 1:Enable
1.3.6.1.4.1.4756.20.311.20.1.100Columnf100mCpuMember15Remoteread-writecurrentRemote FRM220-F100M Cpu Member 15: 0:Disalbe 1:Enable
1.3.6.1.4.1.4756.20.311.20.1.101Columnf100mPVID0Remoteread-writecurrentRemote FRM220-F100M Port 0 VID :
1.3.6.1.4.1.4756.20.311.20.1.102Columnf100mPVID1Remoteread-writecurrentRemote FRM220-F100M Port 1 VID :
1.3.6.1.4.1.4756.20.311.20.1.103Columnf100mPVID2Remoteread-writecurrentRemote FRM220-F100M Port 2 VID :
1.3.6.1.4.1.4756.20.311.20.1.104Columnf100mPVID3Remoteread-writecurrentRemote FRM220-F100M Port 3 VID :
1.3.6.1.4.1.4756.20.311.20.1.105Columnf100mPVID4Remoteread-writecurrentRemote FRM220-F100M Port 4 VID :
1.3.6.1.4.1.4756.20.311.20.1.106Columnf100mPVID5Remoteread-writecurrentRemote FRM220-F100M Port 5 VID :
1.3.6.1.4.1.4756.20.311.20.1.107Columnf100mPVID6Remoteread-writecurrentRemote FRM220-F100M Port 6 VID :
1.3.6.1.4.1.4756.20.311.20.1.108Columnf100mPVID7Remoteread-writecurrentRemote FRM220-F100M Port 7 VID :
1.3.6.1.4.1.4756.20.311.20.1.109Columnf100mPVID8Remoteread-writecurrentRemote FRM220-F100M Port 8 VID :
1.3.6.1.4.1.4756.20.311.20.1.110Columnf100mPVID9Remoteread-writecurrentRemote FRM220-F100M Port 9 VID :
1.3.6.1.4.1.4756.20.311.20.1.111Columnf100mPVID10Remoteread-writecurrentRemote FRM220-F100M Port 10 VID :
1.3.6.1.4.1.4756.20.311.20.1.112Columnf100mPVID11Remoteread-writecurrentRemote FRM220-F100M Port 11 VID :
1.3.6.1.4.1.4756.20.311.20.1.113Columnf100mPVID12Remoteread-writecurrentRemote FRM220-F100M Port 12 VID :
1.3.6.1.4.1.4756.20.311.20.1.114Columnf100mPVID13Remoteread-writecurrentRemote FRM220-F100M Port 13 VID :
1.3.6.1.4.1.4756.20.311.20.1.115Columnf100mPVID14Remoteread-writecurrentRemote FRM220-F100M Port 14 VID :
1.3.6.1.4.1.4756.20.311.20.1.116Columnf100mPVID15Remoteread-writecurrentRemote FRM220-F100M Port 15 VID :
1.3.6.1.4.1.4756.20.311.20.1.117Columnf100mDoubleVLANRemoteread-writecurrentRemote FRM220-F100M Double VLAN: 0:Disable 1:Enable
1.3.6.1.4.1.4756.20.311.20.1.118Columnf100mDoubleVLANTagPriorityRemoteread-writecurrentRemote FRM220-F100M Double VLAN Tag Priority : 0:Internal 1:Remark
1.3.6.1.4.1.4756.20.311.20.1.119Columnf100mDoubleVLANDirectionRemoteread-writecurrentRemote FRM220-F100M Double VLAN Direction : 0:TP add,FX Remove 1:FX add,TP Remove
1.3.6.1.4.1.4756.20.311.20.1.120Columnf100mDoubleVLANTagTypeRemoteread-onlycurrentRemote FRM220-F100M Tag Type (HEX) :
1.3.6.1.4.1.4756.20.311.20.1.121Columnf100mDoubleVLANVIDRemoteread-writecurrentRemote FRM220-F100M Double VLAN VID :
1.3.6.1.4.1.4756.20.311.20.1.122Columnf100mFxDDRemoteread-onlycurrentRemote device card fiber Digital Diagnostic function: 0:No 1:Yes
1.3.6.1.4.1.4756.20.311.20.1.123Columnf100mDDVendorRemoteread-onlycurrentRemote device card fiber D/D information: Vendor name
1.3.6.1.4.1.4756.20.311.20.1.124Columnf100mDDPartNoRemoteread-onlycurrentRemote device card fiber D/D information: Vendor part number
1.3.6.1.4.1.4756.20.311.20.1.125Columnf100mDDFiberTypeRemoteread-onlycurrentRemote device card fiber D/D information: Fiber Type
1.3.6.1.4.1.4756.20.311.20.1.126Columnf100mDDWaveLenRemoteread-onlycurrentRemote device card fiber D/D information: Wave length
1.3.6.1.4.1.4756.20.311.20.1.127Columnf100mDDWaveLen2Remoteread-onlycurrentRemote device card fiber D/D information: Wave length 2
1.3.6.1.4.1.4756.20.311.20.1.128Columnf100mDDLinkLenRemoteread-onlycurrentRemote device card fiber D/D information: Link length
1.3.6.1.4.1.4756.20.311.20.1.129Columnf100mDDLenUnitRemoteread-onlycurrentRemote device card fiber D/D information: Length Unit
1.3.6.1.4.1.4756.20.311.20.1.130Columnf100mDDStatusRemoteread-onlycurrentRemote device card fiber D/D information: Status Support
1.3.6.1.4.1.4756.20.311.20.1.131Columnf100mDDRxSensRemoteread-onlycurrentRemote device card fiber D/D information: Rx Sensitivity
1.3.6.1.4.1.4756.20.311.20.1.132Columnf100mDDTxPWRRemoteread-onlycurrentRemote device card fiber D/D information: Tx power
1.3.6.1.4.1.4756.20.311.20.1.133Columnf100mDDRxPWRRemoteread-onlycurrentRemote device card fiber D/D information: Rx power
1.3.6.1.4.1.4756.20.311.20.1.134Columnf100mDDTempRemoteread-onlycurrentRemote device card fiber D/D information: Temperature in degree C
1.3.6.1.4.1.4756.20.311.20.1.135Columnf100mDDPWRMarginRemoteread-onlycurrentRemote device card fiber D/D information: Power margin
1.3.6.1.4.1.4756.20.311.20.1.136Columnf100mLBStartRemoteread-writecurrentRemote device card Loop back test : 1:Off 2:Action
1.3.6.1.4.1.4756.20.311.20.1.137Columnf100mLBStartStatusRemoteread-onlycurrentRemote device card Loop back test status : 1:Normal 2:Ok 3:Fail
1.3.6.1.4.1.4756.20.311.20.1.138Columnf100mPower1StatusRemoteread-onlycurrentRemote device card Power1 status (IMC series card only)
1.3.6.1.4.1.4756.20.311.20.1.139Columnf100mPower2StatusRemoteread-onlycurrentRemote device card Power2 status (IMC series card only)
1.3.6.1.4.1.4756.20.311.20.1.140Columnf100mFaultStatusRemoteread-onlycurrentRemote device card Fault status (IMC series card only)
1.3.6.1.4.1.4756.20.311.20.1.141Columnf100mPowerLossRemoteread-writecurrentRemote device card Power Loss Alarm(IMC series card only)
1.3.6.1.4.1.4756.20.311.20.1.142Columnf100mTPLossRemoteread-writecurrentRemote device card TP Loss Alarm(IMC series card only)
1.3.6.1.4.1.4756.20.311.20.1.143Columnf100mFXLossRemoteread-writecurrentRemote device card FX Loss Alarm(IMC series card only)
1.3.6.1.4.1.4756.20.311.20.1.144Columnf100mPoEModeRemoteread-writecurrentRemote device card PoE Mode(IMC-100/1000M(S)-PH12 series card only)
1.3.6.1.4.1.4756.20.311.20.1.145Columnf100mPowerAllocationLimitRemoteread-writecurrentRemote device card Power Allocation Limit [W](IMC-100/1000M(S)-PH12 series card only) 1: 5 W 2: 10 W 3: 15 W 4: 20 W 5: 25 W 6: 30 W
1.3.6.1.4.1.4756.20.311.20.1.146Columnf100mPDClassRemoteread-onlycurrentRemote device card PD Class(IMC-100/1000M(S)-PH12 series card only)
1.3.6.1.4.1.4756.20.311.20.1.147Columnf100mPowerRequestedRemoteread-onlycurrentRemote device card Power Requested(IMC-100/1000M(S)-PH12 series card only)
1.3.6.1.4.1.4756.20.311.20.1.148Columnf100mPowerUsedRemoteread-onlycurrentRemote device card Power Used(IMC-100/1000M(S)-PH12 series card only)
1.3.6.1.4.1.4756.20.311.20.1.149Columnf100mDetectionRemoteread-onlycurrentRemote device card Power Used(IMC-100/1000M(S)-PH12 series card only)
1.3.6.1.4.1.4756.20.320Nodefom01LocalCards
1.3.6.1.4.1.4756.20.320.20Tablefom01LocalTablenot-accessiblecurrentA list of local FRM220-FOM01 series card entries. The number of entries is fom01-No-L.
1.3.6.1.4.1.4756.20.320.20.1Rowfom01LocalEntrynot-accessiblecurrentAn entry containing management information applicable to a particular local FRM220-FOM01 series card.
1.3.6.1.4.1.4756.20.320.20.1.1Columnfom01ChassisIndexLocalread-onlycurrentA unique value for each local card. It is the chassis location number.
1.3.6.1.4.1.4756.20.320.20.1.2Columnfom01SlotIndexLocalread-onlycurrentA unique value for each local card. It is the slot location number.
1.3.6.1.4.1.4756.20.320.20.1.3Columnfom01CardHWVerLocalread-onlycurrentLocal FRM220-FOM01 Series card hardware version x.xxx
1.3.6.1.4.1.4756.20.320.20.1.4Columnfom01CardFWVerLocalread-onlycurrentLocal FRM220-FOM01 Series card firmware version x.xxx
1.3.6.1.4.1.4756.20.320.20.1.5Columnfom01CardCPLDVerLocalread-onlycurrentLocal FRM220-FOM01 Series card CPLD version x.xxx
1.3.6.1.4.1.4756.20.320.20.1.6Columnfom01CardFPGAVerLocalread-onlycurrentLocal FRM220-FOM01 Series card FPGA version x.xxx
1.3.6.1.4.1.4756.20.320.20.1.7Columnfom01PortActiveLocalread-writecurrentLocal FRM220-FOM01 Series card active: 0:Disable 1:Enable
1.3.6.1.4.1.4756.20.320.20.1.8Columnfom01SettoDefaultLocalread-writecurrentLocal FRM220-FOM01 Series card set to default: 0:OFF 1:Action
1.3.6.1.4.1.4756.20.320.20.1.9Columnfom01PortResetLocalread-writecurrentLocal FRM220-FOM01 Series card portreset: 0:OFF 1:Action
1.3.6.1.4.1.4756.20.320.20.1.10Columnfom01FxLinkLocalread-onlycurrentLocal FRM220-FOM01 fiber link status: 0:Down 1:up
1.3.6.1.4.1.4756.20.320.20.1.11Columnfom01FxRxActiveLocalread-onlycurrentLocal FRM220-FOM01 fiber Rx Active: 0:Down 1:up
1.3.6.1.4.1.4756.20.320.20.1.12Columnfom01FxLBSettingLocalread-writecurrentLocal FRM220-FOM01 fiber loop back: 0:Disable 1:LLB 2:RLB
1.3.6.1.4.1.4756.20.320.20.1.13Columnfom01LfpModeLocalread-writecurrentLocal FRM220-FOM01 link fault pass throught: 0:Disable 1:Enable
1.3.6.1.4.1.4756.20.320.20.1.14Columnfom01RemotePWRLocalread-onlycurrentLocal FRM220-FOM01 remote power fail: 0:Ok 1:Abnormal
1.3.6.1.4.1.4756.20.320.20.1.15Columnfom01E1T1TermLocalread-writecurrentLocal FRM220-FOM01 E1/T1 Termination: 0:E1/75/BNC 1:E1/120/RJ45 2:T1/100/RJ45
1.3.6.1.4.1.4756.20.320.20.1.16Columnfom01E1T1ActiveLocalread-writecurrentLocal FRM220-FOM01 E1/T1 active: 0:Disable 1:Enable
1.3.6.1.4.1.4756.20.320.20.1.17Columnfom01E1T1LinkLocalread-onlycurrentLocal FRM220-FOM01 E1/T1 link: 0:Down 1:Up
1.3.6.1.4.1.4756.20.320.20.1.18Columnfom01E1T1BVPErrorLocalread-onlycurrentLocal FRM220-FOM01 E1/T1 BVP error: 0:Normal 1:Error
1.3.6.1.4.1.4756.20.320.20.1.19Columnfom01E1T1LineCodeLocalread-writecurrentLocal FRM220-FOM01 E1/T1 line code: 0:HDB3/B8ZS 1:AMI
1.3.6.1.4.1.4756.20.320.20.1.20Columnfom01E1T1LBSettingLocalread-writecurrentLocal FRM220-FOM01 E1/T1 loop back: 0:Disable 1:LLB 2:RLB
1.3.6.1.4.1.4756.20.320.20.1.21Columnfom01UtpActiveLocalread-writecurrentLocal FRM220-FOM01 UTP active: 0:Disable 1:Enable
1.3.6.1.4.1.4756.20.320.20.1.22Columnfom01UtpLinkLocalread-onlycurrentLocal FRM220-FOM01 UTP link status: 0:Down 1:Up
1.3.6.1.4.1.4756.20.320.20.1.23Columnfom01UtpNegoLocalread-writecurrentLocal FRM220-FOM01 UTP negoiation: 0:Manual 1:Auto
1.3.6.1.4.1.4756.20.320.20.1.24Columnfom01UtpSpeedLocalread-writecurrentLocal FRM220-FOM01 UTP speed: 0:On 1:Off
1.3.6.1.4.1.4756.20.320.20.1.25Columnfom01UtpDuplexLocalread-writecurrentLocal FRM220-FOM01 UTP duplex: 0:Half 1:Full
1.3.6.1.4.1.4756.20.320.20.1.26Columnfom01UtpDuplexSTSLocalread-onlycurrentLocal FRM220-FOM01 UTP Duplex status: 0:Half 1:Full
1.3.6.1.4.1.4756.20.320.20.1.27Columnfom01UtpSpeedSTSLocalread-onlycurrentLocal FRM220-FOM01 UTP speed status: 0:10M 1:100M
1.3.6.1.4.1.4756.20.320.20.1.28Columnfom01FxDDLocalread-onlycurrentLocal device card fiber port Digital Diagnostic function: 0:No 1:Yes
1.3.6.1.4.1.4756.20.320.20.1.29Columnfom01DDVendorLocalread-onlycurrentLocal device card fiber port D/D information: Vendor name
1.3.6.1.4.1.4756.20.320.20.1.30Columnfom01DDPartNoLocalread-onlycurrentLocal device card fiber port D/D information: Vendor part number
1.3.6.1.4.1.4756.20.320.20.1.31Columnfom01DDFiberTypeLocalread-onlycurrentLocal device card fiber port D/D information: Fiber Type
1.3.6.1.4.1.4756.20.320.20.1.32Columnfom01DDWaveLenLocalread-onlycurrentLocal device card fiber port D/D information: Wave length
1.3.6.1.4.1.4756.20.320.20.1.33Columnfom01DDWaveLen2Localread-onlycurrentLocal device card fiber port D/D information: Wave length 2
1.3.6.1.4.1.4756.20.320.20.1.34Columnfom01DDLinkLenLocalread-onlycurrentLocal device card fiber port D/D information: Link length
1.3.6.1.4.1.4756.20.320.20.1.35Columnfom01DDLenUnitLocalread-onlycurrentLocal device card fiber port D/D information: Length Unit
1.3.6.1.4.1.4756.20.320.20.1.36Columnfom01DDStatusLocalread-onlycurrentLocal device card fiber port D/D information: Status Support
1.3.6.1.4.1.4756.20.320.20.1.37Columnfom01DDRxSensLocalread-onlycurrentLocal device card fiber port D/D information: Rx Sensitivity
1.3.6.1.4.1.4756.20.320.20.1.38Columnfom01DDTxPWRLocalread-onlycurrentLocal device card fiber port D/D information: Tx power
1.3.6.1.4.1.4756.20.320.20.1.39Columnfom01DDRxPWRLocalread-onlycurrentLocal device card fiber port D/D information: Rx power
1.3.6.1.4.1.4756.20.320.20.1.40Columnfom01DDTempLocalread-onlycurrentLocal device card fiber port D/D information: Temperature in degree C
1.3.6.1.4.1.4756.20.320.20.1.41Columnfom01DDPWRMarginLocalread-onlycurrentLocal device card fiber port D/D information: Power margin
1.3.6.1.4.1.4756.20.320.20.1.42Columnfom01FxFEFLocalread-onlycurrentLocal device card fiber detected Far End Fault: 0:Undetect 1:Detected
1.3.6.1.4.1.4756.20.321Nodefom01RemoteCards
1.3.6.1.4.1.4756.20.321.20Tablefom01RemoteTablenot-accessiblecurrentA list of local FRM220-FOM01 series card entries. The number of entries is fom01-No-R.
1.3.6.1.4.1.4756.20.321.20.1Rowfom01RemoteEntrynot-accessiblecurrentAn entry containing management information applicable to a particular local FRM220-FOM01 series card.
1.3.6.1.4.1.4756.20.321.20.1.1Columnfom01ChassisIndexRemoteread-onlycurrentA unique value for each local card. It is the chassis location number.
1.3.6.1.4.1.4756.20.321.20.1.2Columnfom01SlotIndexRemoteread-onlycurrentA unique value for each local card. It is the slot location number.
1.3.6.1.4.1.4756.20.321.20.1.3Columnfom01CardHWVerRemoteread-onlycurrentRemote FRM220-FOM01 Series card hardware version x.xxx
1.3.6.1.4.1.4756.20.321.20.1.4Columnfom01CardFWVerRemoteread-onlycurrentRemote FRM220-FOM01 Series card firmware version x.xxx
1.3.6.1.4.1.4756.20.321.20.1.5Columnfom01CardCPLDVerRemoteread-onlycurrentRemote FRM220-FOM01 Series card CPLD version x.xxx
1.3.6.1.4.1.4756.20.321.20.1.6Columnfom01CardFPGAVerRemoteread-onlycurrentRemote FRM220-FOM01 Series card FPGA version x.xxx
1.3.6.1.4.1.4756.20.321.20.1.7Columnfom01SettoDefaultRemoteread-writecurrentRemote FRM220-FOM01 Series card set to default: 0:OFF 1:Action
1.3.6.1.4.1.4756.20.321.20.1.8Columnfom01PortResetRemoteread-writecurrentRemote FRM220-FOM01 Series card portreset: 0:OFF 1:Action
1.3.6.1.4.1.4756.20.321.20.1.9Columnfom01FxLinkRemoteread-onlycurrentRemote FRM220-FOM01 fiber link status: 0:Down 1:up
1.3.6.1.4.1.4756.20.321.20.1.10Columnfom01FxRxActiveRemoteread-onlycurrentRemote FRM220-FOM01 fiber Rx Active: 0:Down 1:up
1.3.6.1.4.1.4756.20.321.20.1.11Columnfom01FxLBSettingRemoteread-writecurrentRemote FRM220-FOM01 fiber loop back: 0:Disable 2:RLB
1.3.6.1.4.1.4756.20.321.20.1.12Columnfom01LfpModeRemoteread-writecurrentRemote FRM220-FOM01 link fault pass throught: 0:Disable 1:Enable
1.3.6.1.4.1.4756.20.321.20.1.13Columnfom01RemotePWRRemoteread-onlycurrentRemote FRM220-FOM01 remote power fail: 0:Ok 1:Abnormal
1.3.6.1.4.1.4756.20.321.20.1.14Columnfom01E1T1TermRemoteread-writecurrentRemote FRM220-FOM01 E1/T1 Termination: 0:E1/75/BNC 1:E1/120/RJ45 2:T1/100/RJ45
1.3.6.1.4.1.4756.20.321.20.1.15Columnfom01E1T1ActiveRemoteread-writecurrentRemote FRM220-FOM01 E1/T1 active: 0:Disable 1:Enable
1.3.6.1.4.1.4756.20.321.20.1.16Columnfom01E1T1LinkRemoteread-onlycurrentRemote FRM220-FOM01 E1/T1 link: 0:Down 1:Up
1.3.6.1.4.1.4756.20.321.20.1.17Columnfom01E1T1BVPErrorRemoteread-onlycurrentRemote FRM220-FOM01 E1/T1 BVP error: 0:Normal 1:Error
1.3.6.1.4.1.4756.20.321.20.1.18Columnfom01E1T1LineCodeRemoteread-writecurrentRemote FRM220-FOM01 E1/T1 line code: 0:HDB3/B8ZS 1:AMI
1.3.6.1.4.1.4756.20.321.20.1.19Columnfom01E1T1LBSettingRemoteread-writecurrentRemote FRM220-FOM01 E1/T1 loop back: 0:Disable 1:LLB 2:RLB
1.3.6.1.4.1.4756.20.321.20.1.20Columnfom01UtpActiveRemoteread-writecurrentRemote FRM220-FOM01 UTP active: 0:Disable 1:Enable
1.3.6.1.4.1.4756.20.321.20.1.21Columnfom01UtpLinkRemoteread-onlycurrentRemote FRM220-FOM01 UTP link status: 0:Down 1:Up
1.3.6.1.4.1.4756.20.321.20.1.22Columnfom01UtpNegoRemoteread-writecurrentRemote FRM220-FOM01 UTP negoiation: 0:Manual 1:Auto
1.3.6.1.4.1.4756.20.321.20.1.23Columnfom01UtpSpeedRemoteread-writecurrentRemote FRM220-FOM01 UTP speed: 0:On 1:Off
1.3.6.1.4.1.4756.20.321.20.1.24Columnfom01UtpDuplexRemoteread-writecurrentRemote FRM220-FOM01 UTP duplex: 0:Half 1:Full
1.3.6.1.4.1.4756.20.321.20.1.25Columnfom01UtpDuplexSTSRemoteread-onlycurrentRemote FRM220-FOM01 UTP duplex status: 0:Half 1:Full
1.3.6.1.4.1.4756.20.321.20.1.26Columnfom01UtpSpeedSTSRemoteread-onlycurrentRemote FRM220-FOM0 UTP speed status: 0:10M 1:100M
1.3.6.1.4.1.4756.20.321.20.1.27Columnfom01FxDDRemoteread-onlycurrentRemote device card fiber port Digital Diagnostic function: 0:No 1:Yes
1.3.6.1.4.1.4756.20.321.20.1.28Columnfom01DDVendorRemoteread-onlycurrentRemote device card fiber port D/D information: Vendor name
1.3.6.1.4.1.4756.20.321.20.1.29Columnfom01DDPartNoRemoteread-onlycurrentRemote device card fiber port D/D information: Vendor part number
1.3.6.1.4.1.4756.20.321.20.1.30Columnfom01DDFiberTypeRemoteread-onlycurrentRemote device card fiber port D/D information: Fiber Type
1.3.6.1.4.1.4756.20.321.20.1.31Columnfom01DDWaveLenRemoteread-onlycurrentRemote device card fiber port D/D information: Wave length
1.3.6.1.4.1.4756.20.321.20.1.32Columnfom01DDWaveLen2Remoteread-onlycurrentRemote device card fiber port D/D information: Wave length 2
1.3.6.1.4.1.4756.20.321.20.1.33Columnfom01DDLinkLenRemoteread-onlycurrentRemote device card fiber port D/D information: Link length
1.3.6.1.4.1.4756.20.321.20.1.34Columnfom01DDLenUnitRemoteread-onlycurrentRemote device card fiber port D/D information: Length Unit
1.3.6.1.4.1.4756.20.321.20.1.35Columnfom01DDStatusRemoteread-onlycurrentRemote device card fiber port D/D information: Status Support
1.3.6.1.4.1.4756.20.321.20.1.36Columnfom01DDRxSensRemoteread-onlycurrentRemote device card fiber port D/D information: Rx Sensitivity
1.3.6.1.4.1.4756.20.321.20.1.37Columnfom01DDTxPWRRemoteread-onlycurrentRemote device card fiber port D/D information: Tx power
1.3.6.1.4.1.4756.20.321.20.1.38Columnfom01DDRxPWRRemoteread-onlycurrentRemote device card fiber port D/D information: Rx power
1.3.6.1.4.1.4756.20.321.20.1.39Columnfom01DDTempRemoteread-onlycurrentRemote device card fiber port D/D information: Temperature in degree C
1.3.6.1.4.1.4756.20.321.20.1.40Columnfom01DDPWRMarginRemoteread-onlycurrentRemote device card fiber port D/D information: Power margin
1.3.6.1.4.1.4756.20.321.20.1.41Columnfom01FxFEFRemoteread-onlycurrentRemote device card fiber detected Far End Fault: 0:Undetect 1:Detected
1.3.6.1.4.1.4756.20.330Nodef1002ESCards
1.3.6.1.4.1.4756.20.330.40Tablef1002ESTablenot-accessiblecurrentA list of local 1002ES card entries.
1.3.6.1.4.1.4756.20.330.40.1Rowf1002ESEntrynot-accessiblecurrentAn entry containing management information applicable to a particular f1002ES card.
1.3.6.1.4.1.4756.20.330.40.1.1Columnf1002ESChassisIndexread-onlycurrentA unique value for each chassis ID. For CH20, it is the chassis ID. For CH08, it is always 0.
1.3.6.1.4.1.4756.20.330.40.1.2Columnf1002ESSlotIndexread-onlycurrentA unique value for each local card. It is the slot location number.
1.3.6.1.4.1.4756.20.330.40.1.3Columnf1002ESCardHWVerread-onlycurrentdevice card hardware version x.xxx
1.3.6.1.4.1.4756.20.330.40.1.4Columnf1002ESCardFWVerread-onlycurrentdevice card firmware version x.xxx
1.3.6.1.4.1.4756.20.330.40.1.5Columnf1002ESCardCPLDVerread-onlycurrentdevice card CPLD version x.xxx
1.3.6.1.4.1.4756.20.330.40.1.6Columnf1002ESCardFPGAVerread-onlycurrentdevice card FPGA version x.xxx
1.3.6.1.4.1.4756.20.330.40.1.7Columnf1002ESFiber1Linkread-onlycurrentdevice card fiber port 1 link status: 0:Down 1:Up
1.3.6.1.4.1.4756.20.330.40.1.8Columnf1002ESFiber1LBTestread-writecurrentForce remote device card to do fiber port 1 LoopBack testing: 0:Off 1:Action
1.3.6.1.4.1.4756.20.330.40.1.9Columnf1002ESFiber1IngressRateread-writecurrentdevice card fiber 1 Ingress Rate Limit: 0 = Unlimit input format: 64k(K),100m(M),100 If doesn't input the unit, the default was Mega. Limite Rate : 64K ~ 990M
1.3.6.1.4.1.4756.20.330.40.1.10Columnf1002ESFiber1EgressRateread-writecurrentdevice card fiber 1 Egress Rate Limit: 0 = Unlimit input format: 64k(K),100m(M),100 If doesn't input the unit, the default was Mega. Limite Rate : 64K ~ 990M
1.3.6.1.4.1.4756.20.330.40.1.11Columnf1002ESFiber2Linkread-onlycurrentdevice card fiber port 2 link status: 0:Down 1:Up
1.3.6.1.4.1.4756.20.330.40.1.12Columnf1002ESFiber2LBTestread-writecurrentForce remote device card to do fiber port 2 LoopBack testing: 0:Off 1:Action
1.3.6.1.4.1.4756.20.330.40.1.13Columnf1002ESFiber2IngressRateread-writecurrentdevice card fiber 2 Ingress Rate Limit: 0 = Unlimit input format: 64k(K),100m(M),100 If doesn't input the unit, the default was Mega. Limite Rate : 64K ~ 990M
1.3.6.1.4.1.4756.20.330.40.1.14Columnf1002ESFiber2EgressRateread-writecurrentdevice card fiber 2 Egress Rate Limit: 0 = Unlimit input format: 64k(K),100m(M),100 If doesn't input the unit, the default was Mega. Limite Rate : 64K ~ 990M
1.3.6.1.4.1.4756.20.330.40.1.15Columnf1002ESUtp3Linkread-onlycurrentdevice card UTP port 3 link status: 0:Down 1:Up
1.3.6.1.4.1.4756.20.330.40.1.16Columnf1002ESUtp3Negoread-writecurrentdevice card UTP port 3 negotiation status: 0:Manual 1:Auto
1.3.6.1.4.1.4756.20.330.40.1.17Columnf1002ESUtp3Speedread-writecurrentdevice card UTP port 3 speed setting: 0:10 Base-T 1:100 Base-TX 2:1000 Base-TX
1.3.6.1.4.1.4756.20.330.40.1.18Columnf1002ESUtp3Duplexread-writecurrentdevice card UTP port 3 duplex setting: 0:Half duplex mode 1:Full duplex mode
1.3.6.1.4.1.4756.20.330.40.1.19Columnf1002ESUtp3SpeedStatusread-onlycurrentdevice card UTP port 3 speed status: 0:10 Base-T 1:100 Base-TX 2:1000 Base-TX
1.3.6.1.4.1.4756.20.330.40.1.20Columnf1002ESUtp3DuplexStatusread-onlycurrentdevice card UTP port 3 duplex status: 0:Half duplex mode 1:Full duplex mode
1.3.6.1.4.1.4756.20.330.40.1.21Columnf1002ESUtp3IngressRateread-writecurrentdevice card utp 3 Ingress Rate Limit: 0 = Unlimit input format: 64k(K),100m(M),100 If doesn't input the unit, the default was Mega. Limite Rate : 64K ~ 990M
1.3.6.1.4.1.4756.20.330.40.1.22Columnf1002ESUtp3EgressRateread-writecurrentdevice card utp 3 Egress Rate Limit: 0 = Unlimit input format: 64k(K),100m(M),100 If doesn't input the unit, the default was Mega. Limite Rate : 64K ~ 990M
1.3.6.1.4.1.4756.20.330.40.1.23Columnf1002ESUtp3LBTestread-writecurrentForce remote device card to do utp port 3 LoopBack testing: 0:Off 1:Action
1.3.6.1.4.1.4756.20.330.40.1.24Columnf1002ESUtp4Linkread-onlycurrentdevice card UTP port 4 link status: 0:Down 1:Up
1.3.6.1.4.1.4756.20.330.40.1.25Columnf1002ESUtp4Negoread-writecurrentdevice card UTP port 4 negotiation status: 0:Manual 1:Auto
1.3.6.1.4.1.4756.20.330.40.1.26Columnf1002ESUtp4Speedread-writecurrentdevice card UTP port 4 speed setting: 0:10 Base-T 1:100 Base-TX 2:1000 Base-TX
1.3.6.1.4.1.4756.20.330.40.1.27Columnf1002ESUtp4Duplexread-writecurrentdevice card UTP port 4 duplex setting: 0:Half duplex mode 1:Full duplex mode
1.3.6.1.4.1.4756.20.330.40.1.28Columnf1002ESUtp4SpeedStatusread-onlycurrentdevice card UTP port 4 speed status: 0:10 Base-T 1:100 Base-TX 2:1000 Base-TX
1.3.6.1.4.1.4756.20.330.40.1.29Columnf1002ESUtp4DuplexStatusread-onlycurrentdevice card UTP port 4 duplex status: 0:Half duplex mode 1:Full duplex mode
1.3.6.1.4.1.4756.20.330.40.1.30Columnf1002ESUtp4IngressRateread-writecurrentdevice card utp 4 Ingress Rate Limit: 0 = Unlimit input format: 64k(K),100m(M),100 If doesn't input the unit, the default was Mega. Limite Rate : 64K ~ 990M
1.3.6.1.4.1.4756.20.330.40.1.31Columnf1002ESUtp4EgressRateread-writecurrentdevice card utp 4 Egress Rate Limit: 0 = Unlimit input format: 64k(K),100m(M),100 If doesn't input the unit, the default was Mega. Limite Rate : 64K ~ 990M
1.3.6.1.4.1.4756.20.330.40.1.32Columnf1002ESUtp4LBTestread-writecurrentForce remote device card to do utp port 4 LoopBack testing: 0:Off 1:Action
1.3.6.1.4.1.4756.20.330.40.1.33Columnf1002ESDeviceActiveread-writecurrentdevice card active mode: (It is read-only in local device.) 0:Disable 1:Enable
1.3.6.1.4.1.4756.20.330.40.1.34Columnf1002ESDeviceResetread-writecurrentForce local device card to reset mode: 0:Off 1:Action
1.3.6.1.4.1.4756.20.330.40.1.35Columnf1002ESFiber1Activeread-writecurrentdevice fiber port 1 active mode: 0:Disable 1:Enable
1.3.6.1.4.1.4756.20.330.40.1.36Columnf1002ESFiber2Activeread-writecurrentdevice fiber port 2 active mode: 0:Disable 1:Enable
1.3.6.1.4.1.4756.20.330.40.1.37Columnf1002ESUtp3Activeread-writecurrentdevice UTP port 3 active mode: 0:Disable 1:Enable
1.3.6.1.4.1.4756.20.330.40.1.38Columnf1002ESUtp4Activeread-writecurrentdevice UTP port 4 active mode: 0:Disable 1:Enable
1.3.6.1.4.1.4756.20.330.40.1.39Columnf1002ESFiber1Alsread-writecurrentdevice card port 1 Auto Laser Shutdown mode: 0:Disable 1:Enable
1.3.6.1.4.1.4756.20.330.40.1.40Columnf1002ESFiber2Alsread-writecurrentdevice card port 2 Auto Laser Shutdown mode: 0:Disable 1:Enable
1.3.6.1.4.1.4756.20.330.40.1.41Columnf1002ESFiber1LLFDepLogiread-writecurrentdevice card port 1 Link Loss Forwarding depends boolean logic: 0:and 1:or
1.3.6.1.4.1.4756.20.330.40.1.42Columnf1002ESFiber1LLFDepPort2read-writecurrentdevice card port 1 Link Loss Forwarding depends on port 2 Fiber Rx link: 0:don't care 1:selected
1.3.6.1.4.1.4756.20.330.40.1.43Columnf1002ESFiber1LLFDepPort3read-writecurrentdevice card port 1 Link Loss Forwarding depends on port 3 Ethernet Rx link: 0:don't care 1:selected
1.3.6.1.4.1.4756.20.330.40.1.44Columnf1002ESFiber1LLFDepPort4read-writecurrentdevice card port 1 Link Loss Forwarding depends on port 4 Ethernet Rx link: 0:don't care 1:selected
1.3.6.1.4.1.4756.20.330.40.1.45Columnf1002ESFiber2LLFDepLogiread-writecurrentdevice card port 2 Link Loss Forwarding depends boolean logic: 0:and 1:or
1.3.6.1.4.1.4756.20.330.40.1.46Columnf1002ESFiber2LLFDepPort1read-writecurrentdevice card port 2 Link Loss Forwarding depends on port 1 Fiber Rx link: 0:don't care 1:selected
1.3.6.1.4.1.4756.20.330.40.1.47Columnf1002ESFiber2LLFDepPort3read-writecurrentdevice card port 2 Link Loss Forwarding depends on port 3 Ethernet Rx link: 0:don't care 1:selected
1.3.6.1.4.1.4756.20.330.40.1.48Columnf1002ESFiber2LLFDepPort4read-writecurrentdevice card port 2 Link Loss Forwarding depends on port 4 Ethernet Rx link: 0:don't care 1:selected
1.3.6.1.4.1.4756.20.330.40.1.49Columnf1002ESUtp3LLFDepLogiread-writecurrentdevice card port 3 Link Loss Forwarding depends boolean logic: 0:and 1:or
1.3.6.1.4.1.4756.20.330.40.1.50Columnf1002ESUtp3LLFDepPort1read-writecurrentdevice card port 3 Link Loss Forwarding depends on port 1 Rx link: 0:don't care 1:selected
1.3.6.1.4.1.4756.20.330.40.1.51Columnf1002ESUtp3LLFDepPort2read-writecurrentdevice card port 3 Link Loss Forwarding depends on port 2 Rx link: 0:don't care 1:selected
1.3.6.1.4.1.4756.20.330.40.1.52Columnf1002ESUtp3LLFDepPort4read-writecurrentdevice card port 3 Link Loss Forwarding depends on port 4 Rx link: 0:don't care 1:selected
1.3.6.1.4.1.4756.20.330.40.1.53Columnf1002ESUtp4LLFDepLogiread-writecurrentdevice card port 4 Link Loss Forwarding depends boolean logic: 0:and 1:or
1.3.6.1.4.1.4756.20.330.40.1.54Columnf1002ESUtp4LLFDepPort1read-writecurrentdevice card port 4 Link Loss Forwarding depends on port 1 Rx link: 0:don't care 1:selected
1.3.6.1.4.1.4756.20.330.40.1.55Columnf1002ESUtp4LLFDepPort2read-writecurrentdevice card port 4 Link Loss Forwarding depends on port 2 Rx link: 0:don't care 1:selected
1.3.6.1.4.1.4756.20.330.40.1.56Columnf1002ESUtp4LLFDepPort3read-writecurrentdevice card port 4 Link Loss Forwarding depends on port 3 Rx link: 0:don't care 1:selected
1.3.6.1.4.1.4756.20.330.40.1.57Columnf1002ESFiber1DDread-onlycurrentdevice card fiber port 1 Digital Diagnostic function: 0:No 1:Yes
1.3.6.1.4.1.4756.20.330.40.1.58Columnf1002ESFiber1DDVendorread-onlycurrentdevice card fiber port 1 D/D information: Vendor name
1.3.6.1.4.1.4756.20.330.40.1.59Columnf1002ESFiber1DDPartNoread-onlycurrentdevice card fiber port 1 D/D information: Vendor part number
1.3.6.1.4.1.4756.20.330.40.1.60Columnf1002ESFiber1DDFiberTyperead-onlycurrentdevice card fiber port 1 D/D information: Fiber Type
1.3.6.1.4.1.4756.20.330.40.1.61Columnf1002ESFiber1DDWaveLenread-onlycurrentdevice card fiber port 1 D/D information: Wave length
1.3.6.1.4.1.4756.20.330.40.1.62Columnf1002ESFiber1DDWaveLen2read-onlycurrentdevice card fiber port 1 D/D information: Wave length 2
1.3.6.1.4.1.4756.20.330.40.1.63Columnf1002ESFiber1DDLinkLenread-onlycurrentdevice card fiber port 1 D/D information: Link length
1.3.6.1.4.1.4756.20.330.40.1.64Columnf1002ESFiber1DDLenUnitread-onlycurrentdevice card fiber port 1 D/D information: Length Unit
1.3.6.1.4.1.4756.20.330.40.1.65Columnf1002ESFiber1DDStatusread-onlycurrentdevice card fiber port 1 D/D information: Status Support
1.3.6.1.4.1.4756.20.330.40.1.66Columnf1002ESFiber1DDRxSensread-onlycurrentdevice card fiber port 1 D/D information: Rx Sensitivity
1.3.6.1.4.1.4756.20.330.40.1.67Columnf1002ESFiber1DDTxPWRread-onlycurrentdevice card fiber port 1 D/D information: Tx power
1.3.6.1.4.1.4756.20.330.40.1.68Columnf1002ESFiber1DDRxPWRread-onlycurrentdevice card fiber port 1 D/D information: Rx power
1.3.6.1.4.1.4756.20.330.40.1.69Columnf1002ESFiber1DDTempread-onlycurrentdevice card fiber port 1 D/D information: Temperature in degree C
1.3.6.1.4.1.4756.20.330.40.1.70Columnf1002ESFiber1DDPWRMarginread-onlycurrentdevice card fiber port 1 D/D information: Power margin
1.3.6.1.4.1.4756.20.330.40.1.71Columnf1002ESFiber1DDPWRLossread-onlycurrentdevice card fiber port 1 D/D information: Power loss
1.3.6.1.4.1.4756.20.330.40.1.72Columnf1002ESFiber2DDread-onlycurrentdevice card fiber port 2 Digital Diagnostic function: 0:No 1:Yes
1.3.6.1.4.1.4756.20.330.40.1.73Columnf1002ESFiber2DDVendorread-onlycurrentdevice card fiber port 2 D/D information: Vendor name
1.3.6.1.4.1.4756.20.330.40.1.74Columnf1002ESFiber2DDPartNoread-onlycurrentdevice card fiber port 2 D/D information: Vendor part number
1.3.6.1.4.1.4756.20.330.40.1.75Columnf1002ESFiber2DDFiberTyperead-onlycurrentdevice card fiber port 2 D/D information: Fiber Type
1.3.6.1.4.1.4756.20.330.40.1.76Columnf1002ESFiber2DDWaveLenread-onlycurrentdevice card fiber port 2 D/D information: Wave length
1.3.6.1.4.1.4756.20.330.40.1.77Columnf1002ESFiber2DDWaveLen2read-onlycurrentdevice card fiber port 2 D/D information: Wave length 2
1.3.6.1.4.1.4756.20.330.40.1.78Columnf1002ESFiber2DDLinkLenread-onlycurrentdevice card fiber port 2 D/D information: Link length
1.3.6.1.4.1.4756.20.330.40.1.79Columnf1002ESFiber2DDLenUnitread-onlycurrentdevice card fiber port 2 D/D information: Length Unit
1.3.6.1.4.1.4756.20.330.40.1.80Columnf1002ESFiber2DDStatusread-onlycurrentdevice card fiber port 2 D/D information: Status Support
1.3.6.1.4.1.4756.20.330.40.1.81Columnf1002ESFiber2DDRxSensread-onlycurrentdevice card fiber port 2 D/D information: Rx Sensitivity
1.3.6.1.4.1.4756.20.330.40.1.82Columnf1002ESFiber2DDTxPWRread-onlycurrentdevice card fiber port 2 D/D information: Tx power
1.3.6.1.4.1.4756.20.330.40.1.83Columnf1002ESFiber2DDRxPWRread-onlycurrentdevice card fiber port 2 D/D information: Rx power
1.3.6.1.4.1.4756.20.330.40.1.84Columnf1002ESFiber2DDTempread-onlycurrentdevice card fiber port 2 D/D information: Temperature in degree C
1.3.6.1.4.1.4756.20.330.40.1.85Columnf1002ESFiber2DDPWRMarginread-onlycurrentdevice card fiber port 2 D/D information: Power margin
1.3.6.1.4.1.4756.20.330.40.1.86Columnf1002ESFiber2DDPWRLossread-onlycurrentdevice card fiber port 2 D/D information: Power loss
1.3.6.1.4.1.4756.20.330.40.1.87Columnf1002ESClrRMONCntsread-writecurrentClear local device card RMON IN/OUT counters: 0:No action 1:Action
1.3.6.1.4.1.4756.20.330.40.1.88Columnf1002ESFiber1RMONInread-onlycurrentdevice card port 1 RMON IN counter.
1.3.6.1.4.1.4756.20.330.40.1.89Columnf1002ESFiber1RMONOutread-onlycurrentdevice card port 1 RMON OUT counter.
1.3.6.1.4.1.4756.20.330.40.1.90Columnf1002ESFiber2RMONInread-onlycurrentdevice card port 2 RMON IN counter.
1.3.6.1.4.1.4756.20.330.40.1.91Columnf1002ESFiber2RMONOutread-onlycurrentdevice card port 2 RMON OUT counter.
1.3.6.1.4.1.4756.20.330.40.1.92Columnf1002ESUtp3RMONInread-onlycurrentdevice card port 3 RMON IN counter.
1.3.6.1.4.1.4756.20.330.40.1.93Columnf1002ESUtp3RMONOutread-onlycurrentdevice card port 3 RMON OUT counter.
1.3.6.1.4.1.4756.20.330.40.1.94Columnf1002ESUtp4RMONInread-onlycurrentdevice card port 4 RMON IN counter.
1.3.6.1.4.1.4756.20.330.40.1.95Columnf1002ESUtp4RMONOutread-onlycurrentdevice card port 4 RMON OUT counter.
1.3.6.1.4.1.4756.20.330.40.1.96Columnf1002ESFiber1Speedread-writecurrentdevice Fiber 1 speed : 0:1000 1:100
1.3.6.1.4.1.4756.20.330.40.1.97Columnf1002ESFiber2Speedread-writecurrentdevice Fiber 2 speed : 0:1000 1:100
1.3.6.1.4.1.4756.20.330.40.1.98Columnf1002ESFiber1VLANread-writecurrentdevice Fiber 1 VLAN group : 0:Group A 1:Group B
1.3.6.1.4.1.4756.20.330.40.1.99Columnf1002ESFiber2VLANread-writecurrentdevice Fiber 2 VLAN group : 0:Group A 1:Group B
1.3.6.1.4.1.4756.20.330.40.1.100Columnf1002ESUtp3VLANread-writecurrentdevice UTP 3 VLAN group : 0:Group A 1:Group B
1.3.6.1.4.1.4756.20.330.40.1.101Columnf1002ESUtp4VLANread-writecurrentdevice UTP 4 VLAN group : 0:Group A 1:Group B
1.3.6.1.4.1.4756.20.330.40.1.102Columnf1002ESPortVLANread-writecurrentdevice Port VLAN mode : 0:Disalbe 1:Enable
1.3.6.1.4.1.4756.20.330.40.1.103Columnf1002ES8021QVLANread-writecurrentdevice 802.1Q VLAN : 0:Disalbe 1:Enable
1.3.6.1.4.1.4756.20.330.40.1.104Columnf1002ESFlowCrlread-writecurrentdevice Flow Control : 0:Disalbe 1:Enable
1.3.6.1.4.1.4756.20.330.40.1.105Columnf1002ESTagTyperead-writecurrentdevice Tag Type (HEX) :
1.3.6.1.4.1.4756.20.330.40.1.106Columnf1002ESPort1VIDread-writecurrentdevice Port 1 VID :
1.3.6.1.4.1.4756.20.330.40.1.107Columnf1002ESPort2VIDread-writecurrentdevice Port 2 VID :
1.3.6.1.4.1.4756.20.330.40.1.108Columnf1002ESPort3VIDread-writecurrentdevice Port 3 VID :
1.3.6.1.4.1.4756.20.330.40.1.109Columnf1002ESPort4VIDread-writecurrentdevice Port 4 VID :
1.3.6.1.4.1.4756.20.330.40.1.110Columnf1002ESPort1QinQread-writecurrentdevice Port 1 Q in Q Support : 1:Disable 2:Enable
1.3.6.1.4.1.4756.20.330.40.1.111Columnf1002ESPort2QinQread-writecurrentdevice Port 2 Q in Q Support : 1:Disable 2:Enable
1.3.6.1.4.1.4756.20.330.40.1.112Columnf1002ESPort3QinQread-writecurrentdevice Port 3 Q in Q Support : 1:Disable 2:Enable
1.3.6.1.4.1.4756.20.330.40.1.113Columnf1002ESPort4QinQread-writecurrentdevice Port 4 Q in Q Support : 1:Disable 2:Enable
1.3.6.1.4.1.4756.20.330.40.1.114Columnf1002ESVID1read-writecurrentdevice VID 1:
1.3.6.1.4.1.4756.20.330.40.1.115Columnf1002ESVID2read-writecurrentdevice VID 2:
1.3.6.1.4.1.4756.20.330.40.1.116Columnf1002ESVID3read-writecurrentdevice VID 3:
1.3.6.1.4.1.4756.20.330.40.1.117Columnf1002ESVID4read-writecurrentdevice VID 4:
1.3.6.1.4.1.4756.20.330.40.1.118Columnf1002ESVID5read-writecurrentdevice VID 5:
1.3.6.1.4.1.4756.20.330.40.1.119Columnf1002ESVID6read-writecurrentdevice VID 6:
1.3.6.1.4.1.4756.20.330.40.1.120Columnf1002ESVID7read-writecurrentdevice VID 7:
1.3.6.1.4.1.4756.20.330.40.1.121Columnf1002ESVID8read-writecurrentdevice VID 8:
1.3.6.1.4.1.4756.20.330.40.1.122Columnf1002ESVID9read-writecurrentdevice VID 9:
1.3.6.1.4.1.4756.20.330.40.1.123Columnf1002ESVID10read-writecurrentdevice VID 10:
1.3.6.1.4.1.4756.20.330.40.1.124Columnf1002ESVID11read-writecurrentdevice VID 11:
1.3.6.1.4.1.4756.20.330.40.1.125Columnf1002ESVID12read-writecurrentdevice VID 12:
1.3.6.1.4.1.4756.20.330.40.1.126Columnf1002ESVID13read-writecurrentdevice VID 13:
1.3.6.1.4.1.4756.20.330.40.1.127Columnf1002ESVID14read-writecurrentdevice VID 14:
1.3.6.1.4.1.4756.20.330.40.1.128Columnf1002ESVID15read-writecurrentdevice VID 15:
1.3.6.1.4.1.4756.20.330.40.1.129Columnf1002ESVID16read-writecurrentdevice VID 16:
1.3.6.1.4.1.4756.20.330.40.1.130Columnf1002ESPort1Member1read-writecurrentdevice card port 1 member: 0:Unmodify 1:Untagged 2:Tagged 3:Nonmember
1.3.6.1.4.1.4756.20.330.40.1.131Columnf1002ESPort1Member2read-writecurrentdevice card port 1 member 2: 0:Unmodify 1:Untagged 2:Tagged 3:Nonmember
1.3.6.1.4.1.4756.20.330.40.1.132Columnf1002ESPort1Member3read-writecurrentdevice card port 1 member 3: 0:Unmodify 1:Untagged 2:Tagged 3:Nonmember
1.3.6.1.4.1.4756.20.330.40.1.133Columnf1002ESPort1Member4read-writecurrentdevice card port 1 member 4: 0:Unmodify 1:Untagged 2:Tagged 3:Nonmember
1.3.6.1.4.1.4756.20.330.40.1.134Columnf1002ESPort1Member5read-writecurrentdevice card port 1 member 5: 0:Unmodify 1:Untagged 2:Tagged 3:Nonmember
1.3.6.1.4.1.4756.20.330.40.1.135Columnf1002ESPort1Member6read-writecurrentdevice card port 1 member 6: 0:Unmodify 1:Untagged 2:Tagged 3:Nonmember
1.3.6.1.4.1.4756.20.330.40.1.136Columnf1002ESPort1Member7read-writecurrentdevice card port 1 member 7: 0:Unmodify 1:Untagged 2:Tagged 3:Nonmember
1.3.6.1.4.1.4756.20.330.40.1.137Columnf1002ESPort1Member8read-writecurrentdevice card port 1 member 8: 0:Unmodify 1:Untagged 2:Tagged 3:Nonmember
1.3.6.1.4.1.4756.20.330.40.1.138Columnf1002ESPort1Member9read-writecurrentdevice card port 1 member 9: 0:Unmodify 1:Untagged 2:Tagged 3:Nonmember
1.3.6.1.4.1.4756.20.330.40.1.139Columnf1002ESPort1Member10read-writecurrentdevice card port 1 member 10: 0:Unmodify 1:Untagged 2:Tagged 3:Nonmember
1.3.6.1.4.1.4756.20.330.40.1.140Columnf1002ESPort1Member11read-writecurrentdevice card port 1 member 11: 0:Unmodify 1:Untagged 2:Tagged 3:Nonmember
1.3.6.1.4.1.4756.20.330.40.1.141Columnf1002ESPort1Member12read-writecurrentdevice card port 1 member 12: 0:Unmodify 1:Untagged 2:Tagged 3:Nonmember
1.3.6.1.4.1.4756.20.330.40.1.142Columnf1002ESPort1Member13read-writecurrentdevice card port 1 member 13: 0:Unmodify 1:Untagged 2:Tagged 3:Nonmember
1.3.6.1.4.1.4756.20.330.40.1.143Columnf1002ESPort1Member14read-writecurrentdevice card port 1 member 14: 0:Unmodify 1:Untagged 2:Tagged 3:Nonmember
1.3.6.1.4.1.4756.20.330.40.1.144Columnf1002ESPort1Member15read-writecurrentdevice card port 1 member 15: 0:Unmodify 1:Untagged 2:Tagged 3:Nonmember
1.3.6.1.4.1.4756.20.330.40.1.145Columnf1002ESPort1Member16read-writecurrentdevice card port 1 member 16: 0:Unmodify 1:Untagged 2:Tagged 3:Nonmember
1.3.6.1.4.1.4756.20.330.40.1.146Columnf1002ESPort2Member1read-writecurrentdevice card port 2 member: 0:Unmodify 1:Untagged 2:Tagged 3:Nonmember
1.3.6.1.4.1.4756.20.330.40.1.147Columnf1002ESPort2Member2read-writecurrentdevice card port 2 member 2: 0:Unmodify 1:Untagged 2:Tagged 3:Nonmember
1.3.6.1.4.1.4756.20.330.40.1.148Columnf1002ESPort2Member3read-writecurrentdevice card port 2 member 3: 0:Unmodify 1:Untagged 2:Tagged 3:Nonmember
1.3.6.1.4.1.4756.20.330.40.1.149Columnf1002ESPort2Member4read-writecurrentdevice card port 2 member 4: 0:Unmodify 1:Untagged 2:Tagged 3:Nonmember
1.3.6.1.4.1.4756.20.330.40.1.150Columnf1002ESPort2Member5read-writecurrentdevice card port 2 member 5: 0:Unmodify 1:Untagged 2:Tagged 3:Nonmember
1.3.6.1.4.1.4756.20.330.40.1.151Columnf1002ESPort2Member6read-writecurrentdevice card port 2 member 6: 0:Unmodify 1:Untagged 2:Tagged 3:Nonmember
1.3.6.1.4.1.4756.20.330.40.1.152Columnf1002ESPort2Member7read-writecurrentdevice card port 2 member 7: 0:Unmodify 1:Untagged 2:Tagged 3:Nonmember
1.3.6.1.4.1.4756.20.330.40.1.153Columnf1002ESPort2Member8read-writecurrentdevice card port 2 member 8: 0:Unmodify 1:Untagged 2:Tagged 3:Nonmember
1.3.6.1.4.1.4756.20.330.40.1.154Columnf1002ESPort2Member9read-writecurrentdevice card port 2 member 9: 0:Unmodify 1:Untagged 2:Tagged 3:Nonmember
1.3.6.1.4.1.4756.20.330.40.1.155Columnf1002ESPort2Member10read-writecurrentdevice card port 2 member 10: 0:Unmodify 1:Untagged 2:Tagged 3:Nonmember
1.3.6.1.4.1.4756.20.330.40.1.156Columnf1002ESPort2Member11read-writecurrentdevice card port 2 member 11: 0:Unmodify 1:Untagged 2:Tagged 3:Nonmember
1.3.6.1.4.1.4756.20.330.40.1.157Columnf1002ESPort2Member12read-writecurrentdevice card port 2 member 12: 0:Unmodify 1:Untagged 2:Tagged 3:Nonmember
1.3.6.1.4.1.4756.20.330.40.1.158Columnf1002ESPort2Member13read-writecurrentdevice card port 2 member 13: 0:Unmodify 1:Untagged 2:Tagged 3:Nonmember
1.3.6.1.4.1.4756.20.330.40.1.159Columnf1002ESPort2Member14read-writecurrentdevice card port 2 member 14: 0:Unmodify 1:Untagged 2:Tagged 3:Nonmember
1.3.6.1.4.1.4756.20.330.40.1.160Columnf1002ESPort2Member15read-writecurrentdevice card port 2 member 15: 0:Unmodify 1:Untagged 2:Tagged 3:Nonmember
1.3.6.1.4.1.4756.20.330.40.1.161Columnf1002ESPort2Member16read-writecurrentdevice card port 2 member 16: 0:Unmodify 1:Untagged 2:Tagged 3:Nonmember
1.3.6.1.4.1.4756.20.330.40.1.162Columnf1002ESPort3Member1read-writecurrentdevice card port 3 member: 0:Unmodify 1:Untagged 2:Tagged 3:Nonmember
1.3.6.1.4.1.4756.20.330.40.1.163Columnf1002ESPort3Member2read-writecurrentdevice card port 3 member 2: 0:Unmodify 1:Untagged 2:Tagged 3:Nonmember
1.3.6.1.4.1.4756.20.330.40.1.164Columnf1002ESPort3Member3read-writecurrentdevice card port 3 member 3: 0:Unmodify 1:Untagged 2:Tagged 3:Nonmember
1.3.6.1.4.1.4756.20.330.40.1.165Columnf1002ESPort3Member4read-writecurrentdevice card port 3 member 4: 0:Unmodify 1:Untagged 2:Tagged 3:Nonmember
1.3.6.1.4.1.4756.20.330.40.1.166Columnf1002ESPort3Member5read-writecurrentdevice card port 3 member 5: 0:Unmodify 1:Untagged 2:Tagged 3:Nonmember
1.3.6.1.4.1.4756.20.330.40.1.167Columnf1002ESPort3Member6read-writecurrentdevice card port 3 member 6: 0:Unmodify 1:Untagged 2:Tagged 3:Nonmember
1.3.6.1.4.1.4756.20.330.40.1.168Columnf1002ESPort3Member7read-writecurrentdevice card port 3 member 7: 0:Unmodify 1:Untagged 2:Tagged 3:Nonmember
1.3.6.1.4.1.4756.20.330.40.1.169Columnf1002ESPort3Member8read-writecurrentdevice card port 3 member 8: 0:Unmodify 1:Untagged 2:Tagged 3:Nonmember
1.3.6.1.4.1.4756.20.330.40.1.170Columnf1002ESPort3Member9read-writecurrentdevice card port 3 member 9: 0:Unmodify 1:Untagged 2:Tagged 3:Nonmember
1.3.6.1.4.1.4756.20.330.40.1.171Columnf1002ESPort3Member10read-writecurrentdevice card port 3 member 10: 0:Unmodify 1:Untagged 2:Tagged 3:Nonmember
1.3.6.1.4.1.4756.20.330.40.1.172Columnf1002ESPort3Member11read-writecurrentdevice card port 3 member 11: 0:Unmodify 1:Untagged 2:Tagged 3:Nonmember
1.3.6.1.4.1.4756.20.330.40.1.173Columnf1002ESPort3Member12read-writecurrentdevice card port 3 member 12: 0:Unmodify 1:Untagged 2:Tagged 3:Nonmember
1.3.6.1.4.1.4756.20.330.40.1.174Columnf1002ESPort3Member13read-writecurrentdevice card port 3 member 13: 0:Unmodify 1:Untagged 2:Tagged 3:Nonmember
1.3.6.1.4.1.4756.20.330.40.1.175Columnf1002ESPort3Member14read-writecurrentdevice card port 3 member 14: 0:Unmodify 1:Untagged 2:Tagged 3:Nonmember
1.3.6.1.4.1.4756.20.330.40.1.176Columnf1002ESPort3Member15read-writecurrentdevice card port 3 member 15: 0:Unmodify 1:Untagged 2:Tagged 3:Nonmember
1.3.6.1.4.1.4756.20.330.40.1.177Columnf1002ESPort3Member16read-writecurrentdevice card port 3 member 16: 0:Unmodify 1:Untagged 2:Tagged 3:Nonmember
1.3.6.1.4.1.4756.20.330.40.1.178Columnf1002ESPort4Member1read-writecurrentdevice card port 4 member: 0:Unmodify 1:Untagged 2:Tagged 3:Nonmember
1.3.6.1.4.1.4756.20.330.40.1.179Columnf1002ESPort4Member2read-writecurrentdevice card port 4 member 2: 0:Unmodify 1:Untagged 2:Tagged 3:Nonmember
1.3.6.1.4.1.4756.20.330.40.1.180Columnf1002ESPort4Member3read-writecurrentdevice card port 4 member 3: 0:Unmodify 1:Untagged 2:Tagged 3:Nonmember
1.3.6.1.4.1.4756.20.330.40.1.181Columnf1002ESPort4Member4read-writecurrentdevice card port 4 member 4: 0:Unmodify 1:Untagged 2:Tagged 3:Nonmember
1.3.6.1.4.1.4756.20.330.40.1.182Columnf1002ESPort4Member5read-writecurrentdevice card port 4 member 5: 0:Unmodify 1:Untagged 2:Tagged 3:Nonmember
1.3.6.1.4.1.4756.20.330.40.1.183Columnf1002ESPort4Member6read-writecurrentdevice card port 4 member 6: 0:Unmodify 1:Untagged 2:Tagged 3:Nonmember
1.3.6.1.4.1.4756.20.330.40.1.184Columnf1002ESPort4Member7read-writecurrentdevice card port 4 member 7: 0:Unmodify 1:Untagged 2:Tagged 3:Nonmember
1.3.6.1.4.1.4756.20.330.40.1.185Columnf1002ESPort4Member8read-writecurrentdevice card port 4 member 8: 0:Unmodify 1:Untagged 2:Tagged 3:Nonmember
1.3.6.1.4.1.4756.20.330.40.1.186Columnf1002ESPort4Member9read-writecurrentdevice card port 4 member 9: 0:Unmodify 1:Untagged 2:Tagged 3:Nonmember
1.3.6.1.4.1.4756.20.330.40.1.187Columnf1002ESPort4Member10read-writecurrentdevice card port 4 member 10: 0:Unmodify 1:Untagged 2:Tagged 3:Nonmember
1.3.6.1.4.1.4756.20.330.40.1.188Columnf1002ESPort4Member11read-writecurrentdevice card port 4 member 11: 0:Unmodify 1:Untagged 2:Tagged 3:Nonmember
1.3.6.1.4.1.4756.20.330.40.1.189Columnf1002ESPort4Member12read-writecurrentdevice card port 4 member 12: 0:Unmodify 1:Untagged 2:Tagged 3:Nonmember
1.3.6.1.4.1.4756.20.330.40.1.190Columnf1002ESPort4Member13read-writecurrentdevice card port 4 member 13: 0:Unmodify 1:Untagged 2:Tagged 3:Nonmember
1.3.6.1.4.1.4756.20.330.40.1.191Columnf1002ESPort4Member14read-writecurrentdevice card port 4 member 14: 0:Unmodify 1:Untagged 2:Tagged 3:Nonmember
1.3.6.1.4.1.4756.20.330.40.1.192Columnf1002ESPort4Member15read-writecurrentdevice card port 4 member 15: 0:Unmodify 1:Untagged 2:Tagged 3:Nonmember
1.3.6.1.4.1.4756.20.330.40.1.193Columnf1002ESPort4Member16read-writecurrentdevice card port 4 member 16: 0:Unmodify 1:Untagged 2:Tagged 3:Nonmember
1.3.6.1.4.1.4756.20.330.40.1.194Columnf1002ESSetToDefaultread-writecurrentdevice card set to default: 0:Off 1:Action
1.3.6.1.4.1.4756.20.340Nodefet100LocalCards
1.3.6.1.4.1.4756.20.340.20Tablefet100LocalTablenot-accessiblecurrentA list of local FRM220-ET100 card entries. The number of entries is fET100-No-L.
1.3.6.1.4.1.4756.20.340.20.1Rowfet100LocalEntrynot-accessiblecurrentAn entry containing management information applicable to a particular local FRM220-ET100 card.
1.3.6.1.4.1.4756.20.340.20.1.1Columnfet100ChassisIndexLocalread-onlycurrentA unique value for each local card. It is the chassis location number.
1.3.6.1.4.1.4756.20.340.20.1.2Columnfet100SlotIndexLocalread-onlycurrentA unique value for each local card. It is the slot location number.
1.3.6.1.4.1.4756.20.340.20.1.3Columnfet100CardHWVerLocalread-onlycurrentLocal FRM220-ET100 card hardware version x.xxx
1.3.6.1.4.1.4756.20.340.20.1.4Columnfet100CardFWVerLocalread-onlycurrentLocal FRM220-ET100 card firmware version x.xxx
1.3.6.1.4.1.4756.20.340.20.1.5Columnfet100CardCPLDVerLocalread-onlycurrentLocal FRM220-ET100 card CPLD version x.xxx
1.3.6.1.4.1.4756.20.340.20.1.6Columnfet100CardFPGAVerLocalread-onlycurrentLocal FRM220-ET100 card FPGA version x.xxx
1.3.6.1.4.1.4756.20.340.20.1.7Columnfet100PortActiveLocalread-writecurrentLocal FRM220-ET100 card active: 0:Disable 1:Enable
1.3.6.1.4.1.4756.20.340.20.1.8Columnfet100PortResetLocalread-writecurrentForce local FRM220-ET100 card to reset mode: 0:Off 1:Action
1.3.6.1.4.1.4756.20.340.20.1.9Columnfet100SetDefaultLocalread-writecurrentForce local FRM220-ET100 card to default status: 0:Off 1:Action
1.3.6.1.4.1.4756.20.340.20.1.10Columnfet100PowerLedLocalread-onlycurrentLocal FRM220-ET100 card Power led status: 0:Off 1:On 2:Flash
1.3.6.1.4.1.4756.20.340.20.1.11Columnfet100SYSLedLocalread-onlycurrentLocal FRM220-ET100 card system led status: 0:Off 1:On
1.3.6.1.4.1.4756.20.340.20.1.12Columnfet100AlarmLedLocalread-onlycurrentLocal FRM220-ET100 card alarm led status: 0:Off 1:On
1.3.6.1.4.1.4756.20.340.20.1.13Columnfet100TestLedLocalread-onlycurrentLocal FRM220-ET100 card test led status: 0:Off 1:On
1.3.6.1.4.1.4756.20.340.20.1.14Columnfet100FxLinkLocalread-onlycurrentLocal FRM220-ET100 card fiber link: 0:Down 1:Up
1.3.6.1.4.1.4756.20.340.20.1.15Columnfet100FxSignalAppearLocalread-onlycurrentLocal FRM220-ET100 card fiber signal appear: 0:Off 1:Have
1.3.6.1.4.1.4756.20.340.20.1.16Columnfet100FxSignalLossLocalread-onlycurrentLocal FRM220-ET100 card fiber singal loss: 0:Off 1:Have
1.3.6.1.4.1.4756.20.340.20.1.17Columnfet100FxSignalLocalread-onlycurrentLocal FRM220-ET100 card signal : 0:No 1:Yes
1.3.6.1.4.1.4756.20.340.20.1.18Columnfet100FEFLocalread-onlycurrentLocal FRM220-ET100 card fiber detected Far End Fault: 0:Off 1:Detected
1.3.6.1.4.1.4756.20.340.20.1.19Columnfet100FxTypeLocalread-onlycurrentLocal FRM220-ET100 card fiber type: 0:1*9 1:SFP
1.3.6.1.4.1.4756.20.340.20.1.20Columnfet100AlsLocalread-writecurrentLocal FRM220-ET100 card Auto Laser Shutdown: 0:disable 1:enable
1.3.6.1.4.1.4756.20.340.20.1.21Columnfet100E1T1selLocalread-writecurrentLocal FRM220-ET100 card ET100 Select: 0:e1 1:t1
1.3.6.1.4.1.4756.20.340.20.1.22Columnfet100FullFractionalLocalread-writecurrentLocal FRM220-ET100 card ET100 Full/Fractional: 0:full-e1t1 1:fraction-e1t1
1.3.6.1.4.1.4756.20.340.20.1.23Columnfet100FramerLocalread-writecurrentLocal FRM220-ET100 card ET100 Framer setting: 0:ccs-d4 1:cas-esf
1.3.6.1.4.1.4756.20.340.20.1.24Columnfet100CrcLocalread-writecurrentLocal FRM220-ET100 card CRC setting: 0:disable 1:enable
1.3.6.1.4.1.4756.20.340.20.1.25Columnfet100UnusedTimeslotCodeLocalread-writecurrentLocal FRM220-ET100 card Unused timeslot code setting: 0:0x7e 1:0xff
1.3.6.1.4.1.4756.20.340.20.1.26Columnfet100TimesourceLocalread-writecurrentLocal FRM220-ET100 card Timing Source: 0:recovery 1:internal
1.3.6.1.4.1.4756.20.340.20.1.27Columnfet100RateLocalread-writecurrentLocal FRM220-ET100 card Active Timeslot Numbers: E1 : CCS Mode CAS Mode T1: 1 64K 64K 64K 2 128K 128K 128K 3 192K 192K 192K 4 256K 256K 256K 5 320K 320K 320K 6…
1.3.6.1.4.1.4756.20.340.20.1.28Columnfet100TimeslotLocalread-writecurrentLocal FRM220-ET100 card Start Timeslot:
1.3.6.1.4.1.4756.20.340.20.1.29Columnfet100LbsettingLocalread-writecurrentLocal FRM220-ET100 card Loop Back setting: 0:off 1:fiber-side-llb 2:fiber-side-rlb 3:fiber-side-rrlb 5:lan-port-side-llb 6:lan-port-side-rlb 7:lan-port-side-rr…
1.3.6.1.4.1.4756.20.340.20.1.30Columnfet100UtpLinkLocalread-onlycurrentLocal FRM220-ET100 card utp link state: 0:Down 1:Up
1.3.6.1.4.1.4756.20.340.20.1.31Columnfet100UtpSpeedSTSLocalread-onlycurrentLocal FRM220-ET100 card utp speed state: 0:10M 1:100M
1.3.6.1.4.1.4756.20.340.20.1.32Columnfet100UtpDuplexSTSLocalread-onlycurrentLocal FRM220-ET100 card utp duplex status: 0:Half 1:Full
1.3.6.1.4.1.4756.20.340.20.1.33Columnfet100UtpNegoLocalread-writecurrentLocal FRM220-ET100 card ET100 utp negoiation: 0:Manual 1:Auto
1.3.6.1.4.1.4756.20.340.20.1.34Columnfet100UtpSpeedLocalread-writecurrentLocal FRM220-ET100 card ET100 utp speed: 0:10M 1:100M
1.3.6.1.4.1.4756.20.340.20.1.35Columnfet100UtpDuplexLocalread-writecurrentLocal FRM220-ET100 card ET100 utp duplex: 0:Half 1:Full
1.3.6.1.4.1.4756.20.340.20.1.36Columnfet100UtpFlowCrlLocalread-writecurrentLocal FRM220-ET100 card ET100 utp flow control: 0:Disable 1:Enable
1.3.6.1.4.1.4756.20.340.20.1.37Columnfet100HDLCFlowCrlLocalread-writecurrentLocal FRM220-ET100 card ET100 HDLC flow control: 0:Disable 1:Enable
1.3.6.1.4.1.4756.20.340.20.1.38Columnfet100FxDDLocalread-onlycurrentLocal FRM220-ET100 card fiber Digital Diagnostic function: 0:No 1:Yes
1.3.6.1.4.1.4756.20.340.20.1.39Columnfet100DDVendorLocalread-onlycurrentLocal FRM220-ET100 card fiber D/D information: Vendor name
1.3.6.1.4.1.4756.20.340.20.1.40Columnfet100DDPartNoLocalread-onlycurrentLocal FRM220-ET100 card fiber D/D information: Vendor part number
1.3.6.1.4.1.4756.20.340.20.1.41Columnfet100DDFiberTypeLocalread-onlycurrentLocal FRM220-ET100 card fiber D/D information: Fiber Type
1.3.6.1.4.1.4756.20.340.20.1.42Columnfet100DDWaveLenLocalread-onlycurrentLocal FRM220-ET100 card fiber D/D information: Wave length
1.3.6.1.4.1.4756.20.340.20.1.43Columnfet100DDWaveLen2Localread-onlycurrentLocal FRM220-ET100 card fiber D/D information: Wave length 2
1.3.6.1.4.1.4756.20.340.20.1.44Columnfet100DDLinkLenLocalread-onlycurrentLocal FRM220-ET100 card fiber D/D information: Link length
1.3.6.1.4.1.4756.20.340.20.1.45Columnfet100DDLenUnitLocalread-onlycurrentLocal FRM220-ET100 card fiber D/D information: Length Unit
1.3.6.1.4.1.4756.20.340.20.1.46Columnfet100DDStatusLocalread-onlycurrentLocal FRM220-ET100 card fiber D/D information: Status Support
1.3.6.1.4.1.4756.20.340.20.1.47Columnfet100DDRxSensLocalread-onlycurrentLocal FRM220-ET100 card fiber D/D information: Rx Sensitivity
1.3.6.1.4.1.4756.20.340.20.1.48Columnfet100DDTxPwrLocalread-onlycurrentLocal FRM220-ET100 card fiber D/D information: Tx power
1.3.6.1.4.1.4756.20.340.20.1.49Columnfet100DDRxPwrLocalread-onlycurrentLocal FRM220-ET100 card fiber D/D information: Rx power
1.3.6.1.4.1.4756.20.340.20.1.50Columnfet100DDTempLocalread-onlycurrentLocal FRM220-ET100 card fiber D/D information: Temperature in degree C
1.3.6.1.4.1.4756.20.340.20.1.51Columnfet100DDPwrMarginLocalread-onlycurrentLocal FRM220-ET100 card fiber D/D information: Power margin
1.3.6.1.4.1.4756.20.340.20.1.52Columnfet100DDPwrLossLocalread-onlycurrentLocal FRM220-ET100 card fiber D/D information: Power loss
1.3.6.1.4.1.4756.20.341Nodefet100RemoteCards
1.3.6.1.4.1.4756.20.341.20Tablefet100RemoteTablenot-accessiblecurrentA list of local FRM220-ET100 card entries. The number of entries is fET100-No-L.
1.3.6.1.4.1.4756.20.341.20.1Rowfet100RemoteEntrynot-accessiblecurrentAn entry containing management information applicable to a particular local FRM220-ET100 card.
1.3.6.1.4.1.4756.20.341.20.1.1Columnfet100ChassisIndexRemoteread-onlycurrentA unique value for each local card. It is the chassis location number.
1.3.6.1.4.1.4756.20.341.20.1.2Columnfet100SlotIndexRemoteread-onlycurrentA unique value for each local card. It is the slot location number.
1.3.6.1.4.1.4756.20.341.20.1.3Columnfet100CardHWVerRemoteread-onlycurrentRemote FRM220-ET100 card hardware version x.xxx
1.3.6.1.4.1.4756.20.341.20.1.4Columnfet100CardFWVerRemoteread-onlycurrentRemote FRM220-ET100 card firmware version x.xxx
1.3.6.1.4.1.4756.20.341.20.1.5Columnfet100CardCPLDVerRemoteread-onlycurrentRemote FRM220-ET100 card CPLD version x.xxx
1.3.6.1.4.1.4756.20.341.20.1.6Columnfet100CardFPGAVerRemoteread-onlycurrentRemote FRM220-ET100 card FPGA version x.xxx
1.3.6.1.4.1.4756.20.341.20.1.7Columnfet100PortResetRemoteread-writecurrentForce local FRM220-ET100 card to reset mode: 0:Off 1:Action
1.3.6.1.4.1.4756.20.341.20.1.8Columnfet100SetDefaultRemoteread-writecurrentForce local FRM220-ET100 card to default status: 0:Off 1:Action
1.3.6.1.4.1.4756.20.341.20.1.9Columnfet100PowerLedRemoteread-onlycurrentRemote FRM220-ET100 card Power led status: 0:Off 1:On 2:Flash
1.3.6.1.4.1.4756.20.341.20.1.10Columnfet100SYSLedRemoteread-onlycurrentRemote FRM220-ET100 card system led status: 0:Off 1:On
1.3.6.1.4.1.4756.20.341.20.1.11Columnfet100AlarmLedRemoteread-onlycurrentRemote FRM220-ET100 card alarm led status: 0:Off 1:On
1.3.6.1.4.1.4756.20.341.20.1.12Columnfet100TestLedRemoteread-onlycurrentRemote FRM220-ET100 card test led status: 0:Off 1:On
1.3.6.1.4.1.4756.20.341.20.1.13Columnfet100FxLinkRemoteread-onlycurrentRemote FRM220-ET100 card fiber link: 0:Down 1:Up
1.3.6.1.4.1.4756.20.341.20.1.14Columnfet100FxSignalAppearRemoteread-onlycurrentRemote FRM220-ET100 card fiber signal appear: 0:Off 1:Have
1.3.6.1.4.1.4756.20.341.20.1.15Columnfet100FxSignalLossRemoteread-onlycurrentRemote FRM220-ET100 card fiber singal loss: 0:Off 1:Have
1.3.6.1.4.1.4756.20.341.20.1.16Columnfet100FxSignalRemoteread-onlycurrentRemote FRM220-ET100 card signal : 0:No 1:Yes
1.3.6.1.4.1.4756.20.341.20.1.17Columnfet100FEFRemoteread-onlycurrentRemote FRM220-ET100 card fiber detected Far End Fault: 0:Off 1:Detected
1.3.6.1.4.1.4756.20.341.20.1.18Columnfet100FxTypeRemoteread-onlycurrentRemote FRM220-ET100 card fiber type: 0:1*9 1:SFP
1.3.6.1.4.1.4756.20.341.20.1.19Columnfet100AlsRemoteread-writecurrentRemote FRM220-ET100 card Auto Laser Shutdown: 0:disable 1:enable
1.3.6.1.4.1.4756.20.341.20.1.20Columnfet100E1T1selRemoteread-writecurrentRemote FRM220-ET100 card ET100 Select: 0:e1 1:t1
1.3.6.1.4.1.4756.20.341.20.1.21Columnfet100FullFractionalRemoteread-writecurrentRemote FRM220-ET100 card ET100 Full/Fractional: 0:full-e1t1 1:fraction-e1t1
1.3.6.1.4.1.4756.20.341.20.1.22Columnfet100FramerRemoteread-writecurrentRemote FRM220-ET100 card ET100 Framer setting: 0:ccs-d4 1:cas-esf
1.3.6.1.4.1.4756.20.341.20.1.23Columnfet100CrcRemoteread-writecurrentRemote FRM220-ET100 card CRC setting: 0:disable 1:enable
1.3.6.1.4.1.4756.20.341.20.1.24Columnfet100UnusedTimeslotCodeRemoteread-writecurrentRemote FRM220-ET100 card Unused timeslot code setting: 0:0x7e 1:0xff
1.3.6.1.4.1.4756.20.341.20.1.25Columnfet100TimesourceRemoteread-writecurrentRemote FRM220-ET100 card Timing Source: 0:recovery 1:internal
1.3.6.1.4.1.4756.20.341.20.1.26Columnfet100RateRemoteread-writecurrentRemote FRM220-ET100 card Active Timeslot Numbers: E1 : CCS Mode CAS Mode T1: 1 64K 64K 64K 2 128K 128K 128K 3 192K 192K 192K 4 256K 256K 256K 5 320K 320K 320K …
1.3.6.1.4.1.4756.20.341.20.1.27Columnfet100TimeslotRemoteread-writecurrentRemote FRM220-ET100 card Start Timeslot:
1.3.6.1.4.1.4756.20.341.20.1.28Columnfet100LbsettingRemoteread-writecurrentRemote FRM220-ET100 card Loop Back setting: 0:off 5:lan-port-side-llb 6:lan-port-side-rlb 7:lan-port-side-rrlb
1.3.6.1.4.1.4756.20.341.20.1.29Columnfet100UtpLinkRemoteread-onlycurrentRemote FRM220-ET100 card utp link state: 0:Down 1:Up
1.3.6.1.4.1.4756.20.341.20.1.30Columnfet100UtpSpeedSTSRemoteread-onlycurrentRemote FRM220-ET100 card utp speed state: 0:10M 1:100M
1.3.6.1.4.1.4756.20.341.20.1.31Columnfet100UtpDuplexSTSRemoteread-onlycurrentRemote FRM220-ET100 card utp duplex status: 0:Half 1:Full
1.3.6.1.4.1.4756.20.341.20.1.32Columnfet100UtpNegoRemoteread-writecurrentRemote FRM220-ET100 card ET100 utp negoiation: 0:Manual 1:Auto
1.3.6.1.4.1.4756.20.341.20.1.33Columnfet100UtpSpeedRemoteread-writecurrentRemote FRM220-ET100 card ET100 utp speed: 0:10M 1:100M
1.3.6.1.4.1.4756.20.341.20.1.34Columnfet100UtpDuplexRemoteread-writecurrentRemote FRM220-ET100 card ET100 utp duplex: 0:Half 1:Full
1.3.6.1.4.1.4756.20.341.20.1.35Columnfet100UtpFlowCrlRemoteread-writecurrentRemote FRM220-ET100 card ET100 utp flow control: 0:Disable 1:Enable
1.3.6.1.4.1.4756.20.341.20.1.36Columnfet100HDLCFlowCrlRemoteread-writecurrentRemote FRM220-ET100 card ET100 HDLC flow control: 0:Disable 1:Enable
1.3.6.1.4.1.4756.20.341.20.1.37Columnfet100FxDDRemoteread-onlycurrentRemote FRM220-ET100 card fiber Digital Diagnostic function: 0:No 1:Yes
1.3.6.1.4.1.4756.20.341.20.1.38Columnfet100DDVendorRemoteread-onlycurrentRemote FRM220-ET100 card fiber D/D information: Vendor name
1.3.6.1.4.1.4756.20.341.20.1.39Columnfet100DDPartNoRemoteread-onlycurrentRemote FRM220-ET100 card fiber D/D information: Vendor part number
1.3.6.1.4.1.4756.20.341.20.1.40Columnfet100DDFiberTypeRemoteread-onlycurrentRemote FRM220-ET100 card fiber D/D information: Fiber Type
1.3.6.1.4.1.4756.20.341.20.1.41Columnfet100DDWaveLenRemoteread-onlycurrentRemote FRM220-ET100 card fiber D/D information: Wave length
1.3.6.1.4.1.4756.20.341.20.1.42Columnfet100DDWaveLen2Remoteread-onlycurrentRemote FRM220-ET100 card fiber D/D information: Wave length 2
1.3.6.1.4.1.4756.20.341.20.1.43Columnfet100DDLinkLenRemoteread-onlycurrentRemote FRM220-ET100 card fiber D/D information: Link length
1.3.6.1.4.1.4756.20.341.20.1.44Columnfet100DDLenUnitRemoteread-onlycurrentRemote FRM220-ET100 card fiber D/D information: Length Unit
1.3.6.1.4.1.4756.20.341.20.1.45Columnfet100DDStatusRemoteread-onlycurrentRemote FRM220-ET100 card fiber D/D information: Status Support
1.3.6.1.4.1.4756.20.341.20.1.46Columnfet100DDRxSensRemoteread-onlycurrentRemote FRM220-ET100 card fiber D/D information: Rx Sensitivity
1.3.6.1.4.1.4756.20.341.20.1.47Columnfet100DDTxPwrRemoteread-onlycurrentRemote FRM220-ET100 card fiber D/D information: Tx power
1.3.6.1.4.1.4756.20.341.20.1.48Columnfet100DDRxPwrRemoteread-onlycurrentRemote FRM220-ET100 card fiber D/D information: Rx power
1.3.6.1.4.1.4756.20.341.20.1.49Columnfet100DDTempRemoteread-onlycurrentRemote FRM220-ET100 card fiber D/D information: Temperature in degree C
1.3.6.1.4.1.4756.20.341.20.1.50Columnfet100DDPwrMarginRemoteread-onlycurrentRemote FRM220-ET100 card fiber D/D information: Power margin
1.3.6.1.4.1.4756.20.341.20.1.51Columnfet100DDPwrLossRemoteread-onlycurrentRemote FRM220-ET100 card fiber D/D information: Power loss
1.3.6.1.4.1.4756.20.350Nodef8E1LocalCards
1.3.6.1.4.1.4756.20.350.20Tablef8E1LocalTablenot-accessiblecurrentA list of local FRM220-8E1-ET100 series card entries. The number of entries is f8E1-No-L.
1.3.6.1.4.1.4756.20.350.20.1Rowf8E1LocalEntrynot-accessiblecurrentAn entry containing management information applicable to a particular local FRM220-8E1 series card.
1.3.6.1.4.1.4756.20.350.20.1.1Columnfa8e1et100ChassisIndexLocalread-onlycurrentA unique value for each card. It starts from 0 to 9 contiguously.
1.3.6.1.4.1.4756.20.350.20.1.2Columnfa8e1et100SlotIndexLocalread-onlycurrentA unique value for each card. It starts from 1 to 20 contiguously.
1.3.6.1.4.1.4756.20.350.20.1.3Columnfa8e1et100CardHWVerLocalread-onlycurrent8E1-ET100(T/S) Series card hardware version x.xxx
1.3.6.1.4.1.4756.20.350.20.1.4Columnfa8e1et100CardFWVerLocalread-onlycurrent8E1-ET100(T/S) Series card firmware version x.xxx
1.3.6.1.4.1.4756.20.350.20.1.5Columnfa8e1et100CardCPLDVerLocalread-onlycurrent8E1-ET100(T/S) Series card CPLD version x.xxx
1.3.6.1.4.1.4756.20.350.20.1.6Columnfa8e1et100CardFPGAVerLocalread-onlycurrent8E1-ET100(T/S) Series card FPGA version x.xxx
1.3.6.1.4.1.4756.20.350.20.1.7Columnfa8e1et100ModelLocalread-onlycurrentCard Type: 0:8E1-ET100T 1:8E1-ET100S
1.3.6.1.4.1.4756.20.350.20.1.8Columnfa8e1et100SystemStatusLocalread-onlycurrent8E1-ET100(T/S) Series card system status: 0:Normal 1:Alarm
1.3.6.1.4.1.4756.20.350.20.1.9Columnfa8e1et100DeviceActiveLocalread-writecurrent8E1-ET100(T/S) Series card active: 0:Disable 1:Enable
1.3.6.1.4.1.4756.20.350.20.1.10Columnfa8e1et100SetToDefaultLocalread-writecurrent8E1-ET100(T/S) Series card port set to default: 0:Off 1:Trigger
1.3.6.1.4.1.4756.20.350.20.1.11Columnfa8e1et100E1Ch1SingalLocalread-onlycurrent8E1-ET100(T/S) Series card E1 channel 1 signal status: 0:Singal Loss 1:Normal
1.3.6.1.4.1.4756.20.350.20.1.12Columnfa8e1et100E1Ch2SingalLocalread-onlycurrent8E1-ET100(T/S) Series card E1 channel 2 signal status: 0:Singal Loss 1:Normal
1.3.6.1.4.1.4756.20.350.20.1.13Columnfa8e1et100E1Ch3SingalLocalread-onlycurrent8E1-ET100(T/S) Series card E1 channel 3 signal status: 0:Singal Loss 1:Normal
1.3.6.1.4.1.4756.20.350.20.1.14Columnfa8e1et100E1Ch4SingalLocalread-onlycurrent8E1-ET100(T/S) Series card E1 channel 4 signal status: 0:Singal Loss 1:Normal
1.3.6.1.4.1.4756.20.350.20.1.15Columnfa8e1et100E1Ch5SingalLocalread-onlycurrent8E1-ET100(T/S) Series card E1 channel 5 signal status: 0:Singal Loss 1:Normal
1.3.6.1.4.1.4756.20.350.20.1.16Columnfa8e1et100E1Ch6SingalLocalread-onlycurrent8E1-ET100(T/S) Series card E1 channel 6 signal status: 0:Singal Loss 1:Normal
1.3.6.1.4.1.4756.20.350.20.1.17Columnfa8e1et100E1Ch7SingalLocalread-onlycurrent8E1-ET100(T/S) Series card E1 channel 7 signal status: 0:Singal Loss 1:Normal
1.3.6.1.4.1.4756.20.350.20.1.18Columnfa8e1et100E1Ch8SingalLocalread-onlycurrent8E1-ET100(T/S) Series card E1 channel 8 signal status: 0:Singal Loss 1:Normal
1.3.6.1.4.1.4756.20.350.20.1.19Columnfa8e1et100E1Ch1SyncLocalread-onlycurrent8E1-ET100(T/S) Series card E1 channel 1 sync status: 0:Sync Loss 1:Sync
1.3.6.1.4.1.4756.20.350.20.1.20Columnfa8e1et100E1Ch2SyncLocalread-onlycurrent8E1-ET100(T/S) Series card E1 channel 2 sync status: 0:Sync Loss 1:Sync
1.3.6.1.4.1.4756.20.350.20.1.21Columnfa8e1et100E1Ch3SyncLocalread-onlycurrent8E1-ET100(T/S) Series card E1 channel 3 sync status: 0:Sync Loss 1:Sync
1.3.6.1.4.1.4756.20.350.20.1.22Columnfa8e1et100E1Ch4SyncLocalread-onlycurrent8E1-ET100(T/S) Series card E1 channel 4 sync status: 0:Sync Loss 1:Sync
1.3.6.1.4.1.4756.20.350.20.1.23Columnfa8e1et100E1Ch5SyncLocalread-onlycurrent8E1-ET100(T/S) Series card E1 channel 5 sync status: 0:Sync Loss 1:Sync
1.3.6.1.4.1.4756.20.350.20.1.24Columnfa8e1et100E1Ch6SyncLocalread-onlycurrent8E1-ET100(T/S) Series card E1 channel 6 sync status: 0:Sync Loss 1:Sync
1.3.6.1.4.1.4756.20.350.20.1.25Columnfa8e1et100E1Ch7SyncLocalread-onlycurrent8E1-ET100(T/S) Series card E1 channel 7 sync status: 0:Sync Loss 1:Sync
1.3.6.1.4.1.4756.20.350.20.1.26Columnfa8e1et100E1Ch8SyncLocalread-onlycurrent8E1-ET100(T/S) Series card E1 channel 8 sync status: 0:Sync Loss 1:Sync
1.3.6.1.4.1.4756.20.350.20.1.27Columnfa8e1et100E1Ch1RecvAISLocalread-onlycurrent8E1-ET100(T/S) Series card E1 channel 1 receive AIS status: 0:No 1:Yes
1.3.6.1.4.1.4756.20.350.20.1.28Columnfa8e1et100E1Ch2RecvAISLocalread-onlycurrent8E1-ET100(T/S) Series card E1 channel 2 receive AIS status: 0:No 1:Yes
1.3.6.1.4.1.4756.20.350.20.1.29Columnfa8e1et100E1Ch3RecvAISLocalread-onlycurrent8E1-ET100(T/S) Series card E1 channel 3 receive AIS status: 0:No 1:Yes
1.3.6.1.4.1.4756.20.350.20.1.30Columnfa8e1et100E1Ch4RecvAISLocalread-onlycurrent8E1-ET100(T/S) Series card E1 channel 4 receive AIS status: 0:No 1:Yes
1.3.6.1.4.1.4756.20.350.20.1.31Columnfa8e1et100E1Ch5RecvAISLocalread-onlycurrent8E1-ET100(T/S) Series card E1 channel 5 receive AIS status: 0:No 1:Yes
1.3.6.1.4.1.4756.20.350.20.1.32Columnfa8e1et100E1Ch6RecvAISLocalread-onlycurrent8E1-ET100(T/S) Series card E1 channel 6 receive AIS status: 0:No 1:Yes
1.3.6.1.4.1.4756.20.350.20.1.33Columnfa8e1et100E1Ch7RecvAISLocalread-onlycurrent8E1-ET100(T/S) Series card E1 channel 7 receive AIS status: 0:No 1:Yes
1.3.6.1.4.1.4756.20.350.20.1.34Columnfa8e1et100E1Ch8RecvAISLocalread-onlycurrent8E1-ET100(T/S) Series card E1 channel 8 receive AIS status: 0:No 1:Yes
1.3.6.1.4.1.4756.20.350.20.1.35Columnfa8e1et100E1Ch1ConnTypeLocalread-onlycurrent8E1-ET100(T/S) Series card E1 channel 1 connector type: 0:RJ-48C 1:BNC
1.3.6.1.4.1.4756.20.350.20.1.36Columnfa8e1et100E1Ch2ConnTypeLocalread-onlycurrent8E1-ET100(T/S) Series card E1 channel 2 connector type: 0:RJ-48C 1:BNC
1.3.6.1.4.1.4756.20.350.20.1.37Columnfa8e1et100E1Ch3ConnTypeLocalread-onlycurrent8E1-ET100(T/S) Series card E1 channel 3 connector type: 0:RJ-48C 1:BNC
1.3.6.1.4.1.4756.20.350.20.1.38Columnfa8e1et100E1Ch4ConnTypeLocalread-onlycurrent8E1-ET100(T/S) Series card E1 channel 4 connector type: 0:RJ-48C 1:BNC
1.3.6.1.4.1.4756.20.350.20.1.39Columnfa8e1et100E1Ch5ConnTypeLocalread-onlycurrent8E1-ET100(T/S) Series card E1 channel 5 connector type: 0:RJ-48C 1:BNC
1.3.6.1.4.1.4756.20.350.20.1.40Columnfa8e1et100E1Ch6ConnTypeLocalread-onlycurrent8E1-ET100(T/S) Series card E1 channel 6 connector type: 0:RJ-48C 1:BNC
1.3.6.1.4.1.4756.20.350.20.1.41Columnfa8e1et100E1Ch7ConnTypeLocalread-onlycurrent8E1-ET100(T/S) Series card E1 channel 7 connector type: 0:RJ-48C 1:BNC
1.3.6.1.4.1.4756.20.350.20.1.42Columnfa8e1et100E1Ch8ConnTypeLocalread-onlycurrent8E1-ET100(T/S) Series card E1 channel 8 connector type: 0:RJ-48C 1:BNC
1.3.6.1.4.1.4756.20.350.20.1.43Columnfa8e1et100E1Ch1RAILocalread-onlycurrent8E1-ET100(T/S) Series card E1 channel 1 RAI status: 0:No 1:Yes
1.3.6.1.4.1.4756.20.350.20.1.44Columnfa8e1et100E1Ch2RAILocalread-onlycurrent8E1-ET100(T/S) Series card E1 channel 2 RAI status: 0:No 1:Yes
1.3.6.1.4.1.4756.20.350.20.1.45Columnfa8e1et100E1Ch3RAILocalread-onlycurrent8E1-ET100(T/S) Series card E1 channel 3 RAI status: 0:No 1:Yes
1.3.6.1.4.1.4756.20.350.20.1.46Columnfa8e1et100E1Ch4RAILocalread-onlycurrent8E1-ET100(T/S) Series card E1 channel 4 RAI status: 0:No 1:Yes
1.3.6.1.4.1.4756.20.350.20.1.47Columnfa8e1et100E1Ch5RAILocalread-onlycurrent8E1-ET100(T/S) Series card E1 channel 5 RAI status: 0:No 1:Yes
1.3.6.1.4.1.4756.20.350.20.1.48Columnfa8e1et100E1Ch6RAILocalread-onlycurrent8E1-ET100(T/S) Series card E1 channel 6 RAI status: 0:No 1:Yes
1.3.6.1.4.1.4756.20.350.20.1.49Columnfa8e1et100E1Ch7RAILocalread-onlycurrent8E1-ET100(T/S) Series card E1 channel 7 RAI status: 0:No 1:Yes
1.3.6.1.4.1.4756.20.350.20.1.50Columnfa8e1et100E1Ch8RAILocalread-onlycurrent8E1-ET100(T/S) Series card E1 channel 8 RAI status: 0:No 1:Yes
1.3.6.1.4.1.4756.20.350.20.1.51Columnfa8e1et100E1Ch1LOMFLocalread-onlycurrent8E1-ET100(T/S) Series card E1 channel 1 LOMF status: 0:No 1:Yes
1.3.6.1.4.1.4756.20.350.20.1.52Columnfa8e1et100E1Ch2LOMFLocalread-onlycurrent8E1-ET100(T/S) Series card E1 channel 2 LOMF status: 0:No 1:Yes
1.3.6.1.4.1.4756.20.350.20.1.53Columnfa8e1et100E1Ch3LOMFLocalread-onlycurrent8E1-ET100(T/S) Series card E1 channel 3 LOMF status: 0:No 1:Yes
1.3.6.1.4.1.4756.20.350.20.1.54Columnfa8e1et100E1Ch4LOMFLocalread-onlycurrent8E1-ET100(T/S) Series card E1 channel 4 LOMF status: 0:No 1:Yes
1.3.6.1.4.1.4756.20.350.20.1.55Columnfa8e1et100E1Ch5LOMFLocalread-onlycurrent8E1-ET100(T/S) Series card E1 channel 5 LOMF status: 0:No 1:Yes
1.3.6.1.4.1.4756.20.350.20.1.56Columnfa8e1et100E1Ch6LOMFLocalread-onlycurrent8E1-ET100(T/S) Series card E1 channel 6 LOMF status: 0:No 1:Yes
1.3.6.1.4.1.4756.20.350.20.1.57Columnfa8e1et100E1Ch7LOMFLocalread-onlycurrent8E1-ET100(T/S) Series card E1 channel 7 LOMF status: 0:No 1:Yes
1.3.6.1.4.1.4756.20.350.20.1.58Columnfa8e1et100E1Ch8LOMFLocalread-onlycurrent8E1-ET100(T/S) Series card E1 channel 8 LOMF status: 0:No 1:Yes
1.3.6.1.4.1.4756.20.350.20.1.59Columnfa8e1et100E1Ch1ActiveLocalread-onlycurrent8E1-ET100(T/S) Series card E1 channel 1 active status: 0:Inactive 1:Active
1.3.6.1.4.1.4756.20.350.20.1.60Columnfa8e1et100E1Ch2ActiveLocalread-onlycurrent8E1-ET100(T/S) Series card E1 channel 2 active status: 0:Inactive 1:Active
1.3.6.1.4.1.4756.20.350.20.1.61Columnfa8e1et100E1Ch3ActiveLocalread-onlycurrent8E1-ET100(T/S) Series card E1 channel 3 active status: 0:Inactive 1:Active
1.3.6.1.4.1.4756.20.350.20.1.62Columnfa8e1et100E1Ch4ActiveLocalread-onlycurrent8E1-ET100(T/S) Series card E1 channel 4 active status: 0:Inactive 1:Active
1.3.6.1.4.1.4756.20.350.20.1.63Columnfa8e1et100E1Ch5ActiveLocalread-onlycurrent8E1-ET100(T/S) Series card E1 channel 5 active status: 0:Inactive 1:Active
1.3.6.1.4.1.4756.20.350.20.1.64Columnfa8e1et100E1Ch6ActiveLocalread-onlycurrent8E1-ET100(T/S) Series card E1 channel 6 active status: 0:Inactive 1:Active
1.3.6.1.4.1.4756.20.350.20.1.65Columnfa8e1et100E1Ch7ActiveLocalread-onlycurrent8E1-ET100(T/S) Series card E1 channel 7 active status: 0:Inactive 1:Active
1.3.6.1.4.1.4756.20.350.20.1.66Columnfa8e1et100E1Ch8ActiveLocalread-onlycurrent8E1-ET100(T/S) Series card E1 channel 8 active status: 0:Inactive 1:Active
1.3.6.1.4.1.4756.20.350.20.1.67Columnfa8e1et100E1Ch1LoopBackLocalread-writecurrent8E1-ET100(T/S) Series card port E1 channel 1 loop back: 0:Off 2:RLB (Max used 4 channels)
1.3.6.1.4.1.4756.20.350.20.1.68Columnfa8e1et100E1Ch2LoopBackLocalread-writecurrent8E1-ET100(T/S) Series card port E1 channel 2 loop back: 0:Off 2:RLB (Max used 4 channels)
1.3.6.1.4.1.4756.20.350.20.1.69Columnfa8e1et100E1Ch3LoopBackLocalread-writecurrent8E1-ET100(T/S) Series card port E1 channel 3 loop back: 0:Off 2:RLB (Max used 4 channels)
1.3.6.1.4.1.4756.20.350.20.1.70Columnfa8e1et100E1Ch4LoopBackLocalread-writecurrent8E1-ET100(T/S) Series card port E1 channel 4 loop back: 0:Off 2:RLB (Max used 4 channels)
1.3.6.1.4.1.4756.20.350.20.1.71Columnfa8e1et100E1Ch5LoopBackLocalread-writecurrent8E1-ET100(T/S) Series card port E1 channel 5 loop back: 0:Off 2:RLB (Max used 4 channels)
1.3.6.1.4.1.4756.20.350.20.1.72Columnfa8e1et100E1Ch6LoopBackLocalread-writecurrent8E1-ET100(T/S) Series card port E1 channel 6 loop back: 0:Off 2:RLB (Max used 4 channels)
1.3.6.1.4.1.4756.20.350.20.1.73Columnfa8e1et100E1Ch7LoopBackLocalread-writecurrent8E1-ET100(T/S) Series card port E1 channel 7 loop back: 0:Off 2:RLB (Max used 4 channels)
1.3.6.1.4.1.4756.20.350.20.1.74Columnfa8e1et100E1Ch8LoopBackLocalread-writecurrent8E1-ET100(T/S) Series card port E1 channel 8 loop back: 0:Off 2:RLB (Max used 4 channels)
1.3.6.1.4.1.4756.20.350.20.1.75Columnfa8e1et100FxLinkLocalread-onlycurrent8E1-ET100S Series card Fiber siganl detect status: 0:Down or Fiber unplugged 1:Up or Singal detected
1.3.6.1.4.1.4756.20.350.20.1.76Columnfa8e1et100FxLaserLocalread-onlycurrent8E1-ET100S Series card laser status: 0:Normal 1:Error
1.3.6.1.4.1.4756.20.350.20.1.77Columnfa8e1et100FxActiveLocalread-writecurrent8E1-ET100S Series card Fiber active: 0:Inactive 1:Active
1.3.6.1.4.1.4756.20.350.20.1.78Columnfa8e1et100FxLaserOutputLocalread-writecurrent8E1-ET100S Series card laser output: 0:disable 1:Enable
1.3.6.1.4.1.4756.20.350.20.1.79Columnfa8e1et100FxOpModeLocalread-writecurrent8E1-ET100S Series card operation mode: 0:Switch 1:Convert
1.3.6.1.4.1.4756.20.350.20.1.80Columnfa8e1et100UtpLinkLocalread-onlycurrent8E1-ET100T Series card UTP link status: 0:Link Down 1:Link Up
1.3.6.1.4.1.4756.20.350.20.1.81Columnfa8e1et100UtpStatusLocalread-onlycurrent8E1-ET100T Series card UTP link mode status: 0:None, Maybe link down 1:Link at 10Mbps, Half duplex 2:Link at 10Mbps, Full duplex 3:Link at 100Mbps, Half duplex…
1.3.6.1.4.1.4756.20.350.20.1.82Columnfa8e1et100UtpFlowCtrlStsLocalread-onlycurrent8E1-ET100T Series card UTP flow control status: 0:Disable 1:Enable
1.3.6.1.4.1.4756.20.350.20.1.83Columnfa8e1et100UtpModeLocalread-writecurrent8E1-ET100T Series card UTP mode: 0:Disable 1:Enable and autoNegotiation 3:Enable and force to 10Mbps, Half duplex 4:Enable and force to 10Mbps, Full duplex 5:E…
1.3.6.1.4.1.4756.20.350.20.1.84Columnfa8e1et100UtpFlowCtrlLocalread-writecurrent8E1-ET100T Series card UTP flow control: 0:Disable 1:Enable
1.3.6.1.4.1.4756.20.350.20.1.85Columnfa8e1et100SpeedLimitLocalread-writecurrent8E1-ET100(T/S) Series card speed limit: Limited = this value * 32Kbps, this value is restricted to 0 ~ 3125, 0 to disable
1.3.6.1.4.1.4756.20.350.20.1.86Columnfa8e1et100VlanAwareLocalread-writecurrent8E1-ET100(T/S) Series card 802.1q VLAN tag aware: 0:Disable 1:Enable
1.3.6.1.4.1.4756.20.350.20.1.87Columnfa8e1et100VlanIDLocalread-writecurrent8E1-ET100(T/S) Series card VLAN ID: The ID is restricted to 1 ~ 4094
1.3.6.1.4.1.4756.20.350.20.1.88Columnfa8e1et100RemoteDeviceLocalread-onlycurrentFRM220A-8E1 Series card remote device status: 0:Link Down 1:Link Up
1.3.6.1.4.1.4756.20.350.20.1.89Columnfa8e1et100RemotePowerLocalread-onlycurrent8E1-ET100(T/S) Series card remote device power status: 0:Normal 1:Power off
1.3.6.1.4.1.4756.20.350.20.1.90Columnfa8e1et100TimingSourceLocalread-writecurrent8E1-ET100(T/S) Series card clock: 0:Internal oscillatro 1:Recovery from E1 channel 1 2:Recovery from E1 channel 2 3:Recovery from E1 channel 3 4:Recovery from …
1.3.6.1.4.1.4756.20.350.20.1.91Columnfa8e1et100FCSofGFPLocalread-writecurrent8E1-ET100(T/S) Series card FCS of GFP: 0:Disable 1:Enable
1.3.6.1.4.1.4756.20.350.20.1.92Columnfa8e1et100AutoChAdjustLocalread-writecurrent8E1-ET100(T/S) Series card auto channel Bdjust: 0:Disable 1:Enable
1.3.6.1.4.1.4756.20.350.20.1.93Columnfa8e1et100PayloadScrambleLocalread-writecurrent8E1-ET100(T/S) Series card payload scramble: 0:Disable 1:Enable
1.3.6.1.4.1.4756.20.350.20.1.94Columnfa8e1et100FailoverLocalread-writecurrent8E1-ET100(T/S) Series card failover: 0:Disable 1:Enable
1.3.6.1.4.1.4756.20.350.20.1.95Columnfa8e1et100LOMLocalread-onlycurrent8E1-ET100(T/S) Series card LOM status: 0:No 1:Yes
1.3.6.1.4.1.4756.20.350.20.1.96Columnfa8e1et100SQMLocalread-onlycurrent8E1-ET100(T/S) Series card SQM status: 0:No 1:Yes
1.3.6.1.4.1.4756.20.350.20.1.97Columnfa8e1et100CRCLocalread-onlycurrent8E1-ET100(T/S) Series card CRC status: 0:No 1:Yes
1.3.6.1.4.1.4756.20.350.20.1.98Columnfa8e1et100LOALocalread-onlycurrent8E1-ET100(T/S) Series card LOA status: 0:No 1:Yes
1.3.6.1.4.1.4756.20.350.20.1.99Columnfa8e1et100LFDLocalread-onlycurrent8E1-ET100(T/S) Series card LFD status: 0:No 1:Yes
1.3.6.1.4.1.4756.20.350.20.1.100Columnfa8e1et100DDTOLocalread-onlycurrent8E1-ET100(T/S) Series card DDTO status: 0:No 1:Yes
1.3.6.1.4.1.4756.20.350.20.1.101Columnfa8e1et100VcatMember1Localread-writecurrent8E1-ET100(T/S) Series card VACT member 0: 0:Disable 1:Enable
1.3.6.1.4.1.4756.20.350.20.1.102Columnfa8e1et100VcatMember2Localread-writecurrent8E1-ET100(T/S) Series card VACT member 1: 0:Disable 1:Enable
1.3.6.1.4.1.4756.20.350.20.1.103Columnfa8e1et100VcatMember3Localread-writecurrent8E1-ET100(T/S) Series card VACT member 3: 0:Disable 1:Enable
1.3.6.1.4.1.4756.20.350.20.1.104Columnfa8e1et100VcatMember4Localread-writecurrent8E1-ET100(T/S) Series card VACT member 4: 0:Disable 1:Enable
1.3.6.1.4.1.4756.20.350.20.1.105Columnfa8e1et100VcatMember5Localread-writecurrent8E1-ET100(T/S) Series card VACT member 5: 0:Disable 1:Enable
1.3.6.1.4.1.4756.20.350.20.1.106Columnfa8e1et100VcatMember6Localread-writecurrent8E1-ET100(T/S) Series card VACT member 6: 0:Disable 1:Enable
1.3.6.1.4.1.4756.20.350.20.1.107Columnfa8e1et100VcatMember7Localread-writecurrent8E1-ET100(T/S) Series card VACT member 7: 0:Disable 1:Enable
1.3.6.1.4.1.4756.20.350.20.1.108Columnfa8e1et100VcatMember8Localread-writecurrent8E1-ET100(T/S) Series card VACT member 8: 0:Disable 1:Enable
1.3.6.1.4.1.4756.20.350.20.1.109Columnfa8e1et100SnmpChannel1Localread-writecurrent8E1-ET100(T/S) Series card SNMP channel 0: 0:No use 1:Use
1.3.6.1.4.1.4756.20.350.20.1.110Columnfa8e1et100SnmpChannel2Localread-writecurrent8E1-ET100(T/S) Series card SNMP channel 1: 0:No use 1:Use
1.3.6.1.4.1.4756.20.350.20.1.111Columnfa8e1et100SnmpChannel3Localread-writecurrent8E1-ET100(T/S) Series card SNMP channel 3: 0:No use 1:Use
1.3.6.1.4.1.4756.20.350.20.1.112Columnfa8e1et100SnmpChannel4Localread-writecurrent8E1-ET100(T/S) Series card SNMP channel 4: 0:No use 1:Use
1.3.6.1.4.1.4756.20.350.20.1.113Columnfa8e1et100ErrSecLocalread-onlycurrent8E1-ET100(T/S) Series card, errored seconds of BERT result.
1.3.6.1.4.1.4756.20.350.20.1.114Columnfa8e1et100ErrFreeSecLocalread-onlycurrent8E1-ET100(T/S) Series card, errored free seconds of BERT result.
1.3.6.1.4.1.4756.20.350.20.1.115Columnfa8e1et100ServErrSecLocalread-onlycurrent8E1-ET100(T/S) Series card, severely errored seconds of BERT result.
1.3.6.1.4.1.4756.20.350.20.1.116Columnfa8e1et100BertFunctionLocalread-writecurrent8E1-ET100(T/S) Series card bert function: 0:Disable 1:Enable
1.3.6.1.4.1.4756.20.350.20.1.117Columnfa8e1et100ClrBertDataLocalread-writecurrent8E1-ET100(T/S) Series card bert data clear: 0:Normal 1:Clear
1.3.6.1.4.1.4756.20.350.20.1.118Columnfa8e1et100BertE1ChannelLocalread-writecurrent8E1-ET100(T/S) Series card bert E1 channel number: 0:E1 channel 1 1:E1 channel 2 2:E1 channel 3 3:E1 channel 4 4:E1 channel 5 5:E1 channel 6 6:E1 channel 7 7:E…
1.3.6.1.4.1.4756.20.350.20.1.119Columnfa8e1et100RmonFunctionLocalread-writecurrent8E1-ET100(T/S) Series RMON function : 0:Disable 1:Enable
1.3.6.1.4.1.4756.20.350.20.1.120Columnfa8e1et100RmonTxLocalread-onlycurrent8E1-ET100(T/S) Series card RMON Tx counter.
1.3.6.1.4.1.4756.20.350.20.1.121Columnfa8e1et100RmonRxLocalread-onlycurrent8E1-ET100(T/S) Series card RMON Rx counter.
1.3.6.1.4.1.4756.20.350.20.1.122Columnfa8e1et100ClrRmonTxLocalread-writecurrent8E1-ET100(T/S) Series card clear RMON Tx counter: 0:Normal 1:Clear
1.3.6.1.4.1.4756.20.350.20.1.123Columnfa8e1et100ClrRmonRxLocalread-writecurrent8E1-ET100(T/S) Series card clear RMON Rx counter: 0:Normal 1:Clear
1.3.6.1.4.1.4756.20.350.20.1.124Columnfa8e1et100SfpLocalread-onlycurrent8E1-ET100(T/S) Series card, SFP existed: 0:No 1:Yes
1.3.6.1.4.1.4756.20.350.20.1.125Columnfa8e1et100SfpVendorLocalread-onlycurrent8E1-ET100(T/S) Series card, Vendor name of SFP.
1.3.6.1.4.1.4756.20.350.20.1.126Columnfa8e1et100SfpPartNoLocalread-onlycurrent8E1-ET100(T/S) Series card, Vendor part number of SFP.
1.3.6.1.4.1.4756.20.350.20.1.127Columnfa8e1et100SfpFiberTypeLocalread-onlycurrent8E1-ET100(T/S) Series card, Fiber Type of SFP.
1.3.6.1.4.1.4756.20.350.20.1.128Columnfa8e1et100SfpTxWaveLenLocalread-onlycurrent8E1-ET100(T/S) Series card, Tx Wave length of SFP.
1.3.6.1.4.1.4756.20.350.20.1.129Columnfa8e1et100SfpRxWaveLenLocalread-onlycurrent8E1-ET100(T/S) Series card, Rx Wave length of SFP.
1.3.6.1.4.1.4756.20.350.20.1.130Columnfa8e1et100SfpLinkLenLocalread-onlycurrent8E1-ET100(T/S) Series card, Link length of SFP.
1.3.6.1.4.1.4756.20.350.20.1.131Columnfa8e1et100SfpModelIDLocalread-onlycurrent8E1-ET100(T/S) Series card, model ID of SFP.
1.3.6.1.4.1.4756.20.350.20.1.132Columnfa8e1et100SfpVersionLocalread-onlycurrent8E1-ET100(T/S) Series card, the version of SFP.
1.3.6.1.4.1.4756.20.350.20.1.133Columnfa8e1et100SfpModelTypeLocalread-onlycurrent8E1-ET100(T/S) Series card, model type of SFP.
1.3.6.1.4.1.4756.20.350.20.1.134Columnfa8e1et100DDInformationLocalread-onlycurrent8E1-ET100(T/S) Series card, D/D information of SFP Supported: 0:No, 1:Yes
1.3.6.1.4.1.4756.20.350.20.1.135Columnfa8e1et100DDRxSensLocalread-onlycurrent8E1-ET100(T/S) Series card, Sensitivity of D/D information.
1.3.6.1.4.1.4756.20.350.20.1.136Columnfa8e1et100DDTxPowerLocalread-onlycurrent8E1-ET100(T/S) Series card, Tx power of D/D information.
1.3.6.1.4.1.4756.20.350.20.1.137Columnfa8e1et100DDRxPowerLocalread-onlycurrent8E1-ET100(T/S) Series card, Rx power of D/D information.
1.3.6.1.4.1.4756.20.350.20.1.138Columnfa8e1et100DDTempLocalread-onlycurrent8E1-ET100(T/S) Series card, Temperature of D/D information in degree C.
1.3.6.1.4.1.4756.20.350.20.1.139Columnfa8e1et100DDBiasLocalread-onlycurrent8E1-ET100(T/S) Series card, BIAS of D/D information.
1.3.6.1.4.1.4756.20.350.20.1.140Columnfa8e1et100DDVoltageLocalread-onlycurrent8E1-ET100(T/S) Series card, Voltage of D/D information.
1.3.6.1.4.1.4756.20.350.20.1.141Columnfa8e1et100ChannelDefectLocalread-writecurrent8E1-ET100(T/S) Series card Channel Defect: 0:Disable 4:1E-4 6:1E-6
1.3.6.1.4.1.4756.20.350.20.1.142Columnfa8e1et100LoopDetectionLocalread-writecurrent8E1-ET100(T/S) Series card Loop Detection: 0:Disable 1:Enable
1.3.6.1.4.1.4756.20.350.20.1.143Columnfa8e1et100LoopCh1Localread-onlycurrent8E1-ET100(T/S) Series card E1 channel 1 Loop Check State: 0:No 1:Yes
1.3.6.1.4.1.4756.20.350.20.1.144Columnfa8e1et100LoopCh2Localread-onlycurrent8E1-ET100(T/S) Series card E1 channel 2 Loop Check State: 0:No 1:Yes
1.3.6.1.4.1.4756.20.350.20.1.145Columnfa8e1et100LoopCh3Localread-onlycurrent8E1-ET100(T/S) Series card E1 channel 3 Loop Check State: 0:No 1:Yes
1.3.6.1.4.1.4756.20.350.20.1.146Columnfa8e1et100LoopCh4Localread-onlycurrent8E1-ET100(T/S) Series card E1 channel 4 Loop Check State: 0:No 1:Yes
1.3.6.1.4.1.4756.20.350.20.1.147Columnfa8e1et100LoopCh5Localread-onlycurrent8E1-ET100(T/S) Series card E1 channel 5 Loop Check State: 0:No 1:Yes
1.3.6.1.4.1.4756.20.350.20.1.148Columnfa8e1et100LoopCh6Localread-onlycurrent8E1-ET100(T/S) Series card E1 channel 6 Loop Check State: 0:No 1:Yes
1.3.6.1.4.1.4756.20.350.20.1.149Columnfa8e1et100LoopCh7Localread-onlycurrent8E1-ET100(T/S) Series card E1 channel 7 Loop Check State: 0:No 1:Yes
1.3.6.1.4.1.4756.20.350.20.1.150Columnfa8e1et100LoopCh8Localread-onlycurrent8E1-ET100(T/S) Series card E1 channel 8 Loop Check State: 0:No 1:Yes
1.3.6.1.4.1.4756.20.350.20.1.151Columnfa8e1et100DefectCh1Localread-onlycurrent8E1-ET100(T/S) Series card E1 channel 1 Defect Status: 0:No 1:Yes
1.3.6.1.4.1.4756.20.350.20.1.152Columnfa8e1et100DefectCh2Localread-onlycurrent8E1-ET100(T/S) Series card E1 channel 2 Defect Status: 0:No 1:Yes
1.3.6.1.4.1.4756.20.350.20.1.153Columnfa8e1et100DefectCh3Localread-onlycurrent8E1-ET100(T/S) Series card E1 channel 3 Defect Status: 0:No 1:Yes
1.3.6.1.4.1.4756.20.350.20.1.154Columnfa8e1et100DefectCh4Localread-onlycurrent8E1-ET100(T/S) Series card E1 channel 4 Defect Status: 0:No 1:Yes
1.3.6.1.4.1.4756.20.350.20.1.155Columnfa8e1et100DefectCh5Localread-onlycurrent8E1-ET100(T/S) Series card E1 channel 5 Defect Status: 0:No 1:Yes
1.3.6.1.4.1.4756.20.350.20.1.156Columnfa8e1et100DefectCh6Localread-onlycurrent8E1-ET100(T/S) Series card E1 channel 6 Defect Status: 0:No 1:Yes
1.3.6.1.4.1.4756.20.350.20.1.157Columnfa8e1et100DefectCh7Localread-onlycurrent8E1-ET100(T/S) Series card E1 channel 7 Defect Status: 0:No 1:Yes
1.3.6.1.4.1.4756.20.350.20.1.158Columnfa8e1et100DefectCh8Localread-onlycurrent8E1-ET100(T/S) Series card E1 channel 8 Defect Status: 0:No 1:Yes
1.3.6.1.4.1.4756.20.350.20.1.159Columnfa8e1et100FxSignalLocalread-onlycurrent8E1-ET100(T/S) Series card Fiber signal detect(SD): 0:Fiber unplugged 1:Signal detected
1.3.6.1.4.1.4756.20.350.20.1.160Columnfa8e1et100PortResetLocalread-writecurrent8E1-ET100(T/S) Series card Port Reset: 0:Action 1:Off
1.3.6.1.4.1.4756.20.350.20.1.161Columnfa8e1et100VLANModeLocalread-writecurrent8E1-ET100(T/S) Series card VLAN mode: 0:MODE2 1:MODE1
1.3.6.1.4.1.4756.20.350.20.1.162Columnfa8e1et100ETagSelectEntryLocalread-writecurrent8E1-ET100(T/S) Series card ETag select entry:
1.3.6.1.4.1.4756.20.350.20.1.163Columnfa8e1et100ETagMethodLocalread-writecurrent8E1-ET100(T/S) Series card ETag Method: 0: Intouch 1: Add Tag 2: Remove Tag
1.3.6.1.4.1.4756.20.350.20.1.164Columnfa8e1et100VLANTableVID1Localread-writecurrent8E1-ET100(T/S) Series card VLAN Table: VLAN ID1
1.3.6.1.4.1.4756.20.350.20.1.165Columnfa8e1et100VLANTableVID2Localread-writecurrent8E1-ET100(T/S) Series card VLAN Table: VLAN ID2
1.3.6.1.4.1.4756.20.350.20.1.166Columnfa8e1et100VLANTableVID3Localread-writecurrent8E1-ET100(T/S) Series card VLAN Table: VLAN ID3
1.3.6.1.4.1.4756.20.350.20.1.167Columnfa8e1et100VLANTableVID4Localread-writecurrent8E1-ET100(T/S) Series card VLAN Table: VLAN ID4
1.3.6.1.4.1.4756.20.350.20.1.168Columnfa8e1et100VLANTableVID5Localread-writecurrent8E1-ET100(T/S) Series card VLAN Table: VLAN ID5
1.3.6.1.4.1.4756.20.350.20.1.169Columnfa8e1et100VLANTableVID6Localread-writecurrent8E1-ET100(T/S) Series card VLAN Table: VLAN ID6
1.3.6.1.4.1.4756.20.350.20.1.170Columnfa8e1et100VLANTableVID7Localread-writecurrent8E1-ET100(T/S) Series card VLAN Table: VLAN ID7
1.3.6.1.4.1.4756.20.350.20.1.171Columnfa8e1et100VLANTableVID8Localread-writecurrent8E1-ET100(T/S) Series card VLAN Table: VLAN ID8
1.3.6.1.4.1.4756.20.350.20.1.172Columnfa8e1et100VLANTableVID9Localread-writecurrent8E1-ET100(T/S) Series card VLAN Table: VLAN ID9
1.3.6.1.4.1.4756.20.350.20.1.173Columnfa8e1et100VLANTableVID10Localread-writecurrent8E1-ET100(T/S) Series card VLAN Table: VLAN ID10
1.3.6.1.4.1.4756.20.350.20.1.174Columnfa8e1et100VLANTableVID11Localread-writecurrent8E1-ET100(T/S) Series card VLAN Table: VLAN ID11
1.3.6.1.4.1.4756.20.350.20.1.175Columnfa8e1et100VLANTableVID12Localread-writecurrent8E1-ET100(T/S) Series card VLAN Table: VLAN ID12
1.3.6.1.4.1.4756.20.350.20.1.176Columnfa8e1et100VLANTableVID13Localread-writecurrent8E1-ET100(T/S) Series card VLAN Table: VLAN ID13
1.3.6.1.4.1.4756.20.350.20.1.177Columnfa8e1et100VLANTableVID14Localread-writecurrent8E1-ET100(T/S) Series card VLAN Table: VLAN ID14
1.3.6.1.4.1.4756.20.350.20.1.178Columnfa8e1et100VLANTableVID15Localread-writecurrent8E1-ET100(T/S) Series card VLAN Table: VLAN ID15
1.3.6.1.4.1.4756.20.350.20.1.179Columnfa8e1et100VLANTableVID16Localread-writecurrent8E1-ET100(T/S) Series card VLAN Table: VLAN ID16
1.3.6.1.4.1.4756.20.351Nodef8E1RemoteCards
1.3.6.1.4.1.4756.20.351.20Tablef8E1RemoteTablenot-accessiblecurrentA list of local FRM220-8E1-ET100 series card entries. The number of entries is f8E1-No-L.
1.3.6.1.4.1.4756.20.351.20.1Rowf8E1RemoteEntrynot-accessiblecurrentAn entry containing management information applicable to a particular local FRM220-8E1 series card.
1.3.6.1.4.1.4756.20.351.20.1.1Columnfa8e1et100ChassisIndexRemoteread-onlycurrentA unique value for each card. It starts from 0 to 9 contiguously.
1.3.6.1.4.1.4756.20.351.20.1.2Columnfa8e1et100SlotIndexRemoteread-onlycurrentA unique value for each card. It starts from 1 to 20 contiguously.
1.3.6.1.4.1.4756.20.351.20.1.3Columnfa8e1et100CardHWVerRemoteread-onlycurrent8E1-ET100(T/S) Series card hardware version x.xxx
1.3.6.1.4.1.4756.20.351.20.1.4Columnfa8e1et100CardFWVerRemoteread-onlycurrent8E1-ET100(T/S) Series card firmware version x.xxx
1.3.6.1.4.1.4756.20.351.20.1.5Columnfa8e1et100CardCPLDVerRemoteread-onlycurrent8E1-ET100(T/S) Series card CPLD version x.xxx
1.3.6.1.4.1.4756.20.351.20.1.6Columnfa8e1et100CardFPGAVerRemoteread-onlycurrent8E1-ET100(T/S) Series card FPGA version x.xxx
1.3.6.1.4.1.4756.20.351.20.1.7Columnfa8e1et100ModelRemoteread-onlycurrentCard Type: 0:8E1-ET100T 1:8E1-ET100S
1.3.6.1.4.1.4756.20.351.20.1.8Columnfa8e1et100SystemStatusRemoteread-onlycurrent8E1-ET100(T/S) Series card system status: 0:Normal 1:Alarm
1.3.6.1.4.1.4756.20.351.20.1.9Columnfa8e1et100DeviceActiveRemoteread-onlycurrent8E1-ET100(T/S) Series card active: 0:Disable 1:Enable
1.3.6.1.4.1.4756.20.351.20.1.10Columnfa8e1et100SetToDefaultRemoteread-writecurrent8E1-ET100(T/S) Series card port set to default: 0:Off 1:Trigger
1.3.6.1.4.1.4756.20.351.20.1.11Columnfa8e1et100E1Ch1SingalRemoteread-onlycurrent8E1-ET100(T/S) Series card E1 channel 1 signal status: 0:Singal Loss 1:Normal
1.3.6.1.4.1.4756.20.351.20.1.12Columnfa8e1et100E1Ch2SingalRemoteread-onlycurrent8E1-ET100(T/S) Series card E1 channel 2 signal status: 0:Singal Loss 1:Normal
1.3.6.1.4.1.4756.20.351.20.1.13Columnfa8e1et100E1Ch3SingalRemoteread-onlycurrent8E1-ET100(T/S) Series card E1 channel 3 signal status: 0:Singal Loss 1:Normal
1.3.6.1.4.1.4756.20.351.20.1.14Columnfa8e1et100E1Ch4SingalRemoteread-onlycurrent8E1-ET100(T/S) Series card E1 channel 4 signal status: 0:Singal Loss 1:Normal
1.3.6.1.4.1.4756.20.351.20.1.15Columnfa8e1et100E1Ch5SingalRemoteread-onlycurrent8E1-ET100(T/S) Series card E1 channel 5 signal status: 0:Singal Loss 1:Normal
1.3.6.1.4.1.4756.20.351.20.1.16Columnfa8e1et100E1Ch6SingalRemoteread-onlycurrent8E1-ET100(T/S) Series card E1 channel 6 signal status: 0:Singal Loss 1:Normal
1.3.6.1.4.1.4756.20.351.20.1.17Columnfa8e1et100E1Ch7SingalRemoteread-onlycurrent8E1-ET100(T/S) Series card E1 channel 7 signal status: 0:Singal Loss 1:Normal
1.3.6.1.4.1.4756.20.351.20.1.18Columnfa8e1et100E1Ch8SingalRemoteread-onlycurrent8E1-ET100(T/S) Series card E1 channel 8 signal status: 0:Singal Loss 1:Normal
1.3.6.1.4.1.4756.20.351.20.1.19Columnfa8e1et100E1Ch1SyncRemoteread-onlycurrent8E1-ET100(T/S) Series card E1 channel 1 sync status: 0:Sync Loss 1:Sync
1.3.6.1.4.1.4756.20.351.20.1.20Columnfa8e1et100E1Ch2SyncRemoteread-onlycurrent8E1-ET100(T/S) Series card E1 channel 2 sync status: 0:Sync Loss 1:Sync
1.3.6.1.4.1.4756.20.351.20.1.21Columnfa8e1et100E1Ch3SyncRemoteread-onlycurrent8E1-ET100(T/S) Series card E1 channel 3 sync status: 0:Sync Loss 1:Sync
1.3.6.1.4.1.4756.20.351.20.1.22Columnfa8e1et100E1Ch4SyncRemoteread-onlycurrent8E1-ET100(T/S) Series card E1 channel 4 sync status: 0:Sync Loss 1:Sync
1.3.6.1.4.1.4756.20.351.20.1.23Columnfa8e1et100E1Ch5SyncRemoteread-onlycurrent8E1-ET100(T/S) Series card E1 channel 5 sync status: 0:Sync Loss 1:Sync
1.3.6.1.4.1.4756.20.351.20.1.24Columnfa8e1et100E1Ch6SyncRemoteread-onlycurrent8E1-ET100(T/S) Series card E1 channel 6 sync status: 0:Sync Loss 1:Sync
1.3.6.1.4.1.4756.20.351.20.1.25Columnfa8e1et100E1Ch7SyncRemoteread-onlycurrent8E1-ET100(T/S) Series card E1 channel 7 sync status: 0:Sync Loss 1:Sync
1.3.6.1.4.1.4756.20.351.20.1.26Columnfa8e1et100E1Ch8SyncRemoteread-onlycurrent8E1-ET100(T/S) Series card E1 channel 8 sync status: 0:Sync Loss 1:Sync
1.3.6.1.4.1.4756.20.351.20.1.27Columnfa8e1et100E1Ch1RecvAISRemoteread-onlycurrent8E1-ET100(T/S) Series card E1 channel 1 receive AIS status: 0:No 1:Yes
1.3.6.1.4.1.4756.20.351.20.1.28Columnfa8e1et100E1Ch2RecvAISRemoteread-onlycurrent8E1-ET100(T/S) Series card E1 channel 2 receive AIS status: 0:No 1:Yes
1.3.6.1.4.1.4756.20.351.20.1.29Columnfa8e1et100E1Ch3RecvAISRemoteread-onlycurrent8E1-ET100(T/S) Series card E1 channel 3 receive AIS status: 0:No 1:Yes
1.3.6.1.4.1.4756.20.351.20.1.30Columnfa8e1et100E1Ch4RecvAISRemoteread-onlycurrent8E1-ET100(T/S) Series card E1 channel 4 receive AIS status: 0:No 1:Yes
1.3.6.1.4.1.4756.20.351.20.1.31Columnfa8e1et100E1Ch5RecvAISRemoteread-onlycurrent8E1-ET100(T/S) Series card E1 channel 5 receive AIS status: 0:No 1:Yes
1.3.6.1.4.1.4756.20.351.20.1.32Columnfa8e1et100E1Ch6RecvAISRemoteread-onlycurrent8E1-ET100(T/S) Series card E1 channel 6 receive AIS status: 0:No 1:Yes
1.3.6.1.4.1.4756.20.351.20.1.33Columnfa8e1et100E1Ch7RecvAISRemoteread-onlycurrent8E1-ET100(T/S) Series card E1 channel 7 receive AIS status: 0:No 1:Yes
1.3.6.1.4.1.4756.20.351.20.1.34Columnfa8e1et100E1Ch8RecvAISRemoteread-onlycurrent8E1-ET100(T/S) Series card E1 channel 8 receive AIS status: 0:No 1:Yes
1.3.6.1.4.1.4756.20.351.20.1.35Columnfa8e1et100E1Ch1ConnTypeRemoteread-onlycurrent8E1-ET100(T/S) Series card E1 channel 1 connector type: 0:RJ-48C 1:BNC
1.3.6.1.4.1.4756.20.351.20.1.36Columnfa8e1et100E1Ch2ConnTypeRemoteread-onlycurrent8E1-ET100(T/S) Series card E1 channel 2 connector type: 0:RJ-48C 1:BNC
1.3.6.1.4.1.4756.20.351.20.1.37Columnfa8e1et100E1Ch3ConnTypeRemoteread-onlycurrent8E1-ET100(T/S) Series card E1 channel 3 connector type: 0:RJ-48C 1:BNC
1.3.6.1.4.1.4756.20.351.20.1.38Columnfa8e1et100E1Ch4ConnTypeRemoteread-onlycurrent8E1-ET100(T/S) Series card E1 channel 4 connector type: 0:RJ-48C 1:BNC
1.3.6.1.4.1.4756.20.351.20.1.39Columnfa8e1et100E1Ch5ConnTypeRemoteread-onlycurrent8E1-ET100(T/S) Series card E1 channel 5 connector type: 0:RJ-48C 1:BNC
1.3.6.1.4.1.4756.20.351.20.1.40Columnfa8e1et100E1Ch6ConnTypeRemoteread-onlycurrent8E1-ET100(T/S) Series card E1 channel 6 connector type: 0:RJ-48C 1:BNC
1.3.6.1.4.1.4756.20.351.20.1.41Columnfa8e1et100E1Ch7ConnTypeRemoteread-onlycurrent8E1-ET100(T/S) Series card E1 channel 7 connector type: 0:RJ-48C 1:BNC
1.3.6.1.4.1.4756.20.351.20.1.42Columnfa8e1et100E1Ch8ConnTypeRemoteread-onlycurrent8E1-ET100(T/S) Series card E1 channel 8 connector type: 0:RJ-48C 1:BNC
1.3.6.1.4.1.4756.20.351.20.1.43Columnfa8e1et100E1Ch1RAIRemoteread-onlycurrent8E1-ET100(T/S) Series card E1 channel 1 RAI status: 0:No 1:Yes
1.3.6.1.4.1.4756.20.351.20.1.44Columnfa8e1et100E1Ch2RAIRemoteread-onlycurrent8E1-ET100(T/S) Series card E1 channel 2 RAI status: 0:No 1:Yes
1.3.6.1.4.1.4756.20.351.20.1.45Columnfa8e1et100E1Ch3RAIRemoteread-onlycurrent8E1-ET100(T/S) Series card E1 channel 3 RAI status: 0:No 1:Yes
1.3.6.1.4.1.4756.20.351.20.1.46Columnfa8e1et100E1Ch4RAIRemoteread-onlycurrent8E1-ET100(T/S) Series card E1 channel 4 RAI status: 0:No 1:Yes
1.3.6.1.4.1.4756.20.351.20.1.47Columnfa8e1et100E1Ch5RAIRemoteread-onlycurrent8E1-ET100(T/S) Series card E1 channel 5 RAI status: 0:No 1:Yes
1.3.6.1.4.1.4756.20.351.20.1.48Columnfa8e1et100E1Ch6RAIRemoteread-onlycurrent8E1-ET100(T/S) Series card E1 channel 6 RAI status: 0:No 1:Yes
1.3.6.1.4.1.4756.20.351.20.1.49Columnfa8e1et100E1Ch7RAIRemoteread-onlycurrent8E1-ET100(T/S) Series card E1 channel 7 RAI status: 0:No 1:Yes
1.3.6.1.4.1.4756.20.351.20.1.50Columnfa8e1et100E1Ch8RAIRemoteread-onlycurrent8E1-ET100(T/S) Series card E1 channel 8 RAI status: 0:No 1:Yes
1.3.6.1.4.1.4756.20.351.20.1.51Columnfa8e1et100E1Ch1LOMFRemoteread-onlycurrent8E1-ET100(T/S) Series card E1 channel 1 LOMF status: 0:No 1:Yes
1.3.6.1.4.1.4756.20.351.20.1.52Columnfa8e1et100E1Ch2LOMFRemoteread-onlycurrent8E1-ET100(T/S) Series card E1 channel 2 LOMF status: 0:No 1:Yes
1.3.6.1.4.1.4756.20.351.20.1.53Columnfa8e1et100E1Ch3LOMFRemoteread-onlycurrent8E1-ET100(T/S) Series card E1 channel 3 LOMF status: 0:No 1:Yes
1.3.6.1.4.1.4756.20.351.20.1.54Columnfa8e1et100E1Ch4LOMFRemoteread-onlycurrent8E1-ET100(T/S) Series card E1 channel 4 LOMF status: 0:No 1:Yes
1.3.6.1.4.1.4756.20.351.20.1.55Columnfa8e1et100E1Ch5LOMFRemoteread-onlycurrent8E1-ET100(T/S) Series card E1 channel 5 LOMF status: 0:No 1:Yes
1.3.6.1.4.1.4756.20.351.20.1.56Columnfa8e1et100E1Ch6LOMFRemoteread-onlycurrent8E1-ET100(T/S) Series card E1 channel 6 LOMF status: 0:No 1:Yes
1.3.6.1.4.1.4756.20.351.20.1.57Columnfa8e1et100E1Ch7LOMFRemoteread-onlycurrent8E1-ET100(T/S) Series card E1 channel 7 LOMF status: 0:No 1:Yes
1.3.6.1.4.1.4756.20.351.20.1.58Columnfa8e1et100E1Ch8LOMFRemoteread-onlycurrent8E1-ET100(T/S) Series card E1 channel 8 LOMF status: 0:No 1:Yes
1.3.6.1.4.1.4756.20.351.20.1.59Columnfa8e1et100E1Ch1ActiveRemoteread-onlycurrent8E1-ET100(T/S) Series card E1 channel 1 active status: 0:Inactive 1:Active
1.3.6.1.4.1.4756.20.351.20.1.60Columnfa8e1et100E1Ch2ActiveRemoteread-onlycurrent8E1-ET100(T/S) Series card E1 channel 2 active status: 0:Inactive 1:Active
1.3.6.1.4.1.4756.20.351.20.1.61Columnfa8e1et100E1Ch3ActiveRemoteread-onlycurrent8E1-ET100(T/S) Series card E1 channel 3 active status: 0:Inactive 1:Active
1.3.6.1.4.1.4756.20.351.20.1.62Columnfa8e1et100E1Ch4ActiveRemoteread-onlycurrent8E1-ET100(T/S) Series card E1 channel 4 active status: 0:Inactive 1:Active
1.3.6.1.4.1.4756.20.351.20.1.63Columnfa8e1et100E1Ch5ActiveRemoteread-onlycurrent8E1-ET100(T/S) Series card E1 channel 5 active status: 0:Inactive 1:Active
1.3.6.1.4.1.4756.20.351.20.1.64Columnfa8e1et100E1Ch6ActiveRemoteread-onlycurrent8E1-ET100(T/S) Series card E1 channel 6 active status: 0:Inactive 1:Active
1.3.6.1.4.1.4756.20.351.20.1.65Columnfa8e1et100E1Ch7ActiveRemoteread-onlycurrent8E1-ET100(T/S) Series card E1 channel 7 active status: 0:Inactive 1:Active
1.3.6.1.4.1.4756.20.351.20.1.66Columnfa8e1et100E1Ch8ActiveRemoteread-onlycurrent8E1-ET100(T/S) Series card E1 channel 8 active status: 0:Inactive 1:Active
1.3.6.1.4.1.4756.20.351.20.1.67Columnfa8e1et100E1Ch1LoopBackRemoteread-writecurrent8E1-ET100(T/S) Series card port E1 channel 1 loop back: 0:Off 2:RLB (Max used 4 channels)
1.3.6.1.4.1.4756.20.351.20.1.68Columnfa8e1et100E1Ch2LoopBackRemoteread-writecurrent8E1-ET100(T/S) Series card port E1 channel 2 loop back: 0:Off 2:RLB (Max used 4 channels)
1.3.6.1.4.1.4756.20.351.20.1.69Columnfa8e1et100E1Ch3LoopBackRemoteread-writecurrent8E1-ET100(T/S) Series card port E1 channel 3 loop back: 0:Off 2:RLB (Max used 4 channels)
1.3.6.1.4.1.4756.20.351.20.1.70Columnfa8e1et100E1Ch4LoopBackRemoteread-writecurrent8E1-ET100(T/S) Series card port E1 channel 4 loop back: 0:Off 2:RLB (Max used 4 channels)
1.3.6.1.4.1.4756.20.351.20.1.71Columnfa8e1et100E1Ch5LoopBackRemoteread-writecurrent8E1-ET100(T/S) Series card port E1 channel 5 loop back: 0:Off 2:RLB (Max used 4 channels)
1.3.6.1.4.1.4756.20.351.20.1.72Columnfa8e1et100E1Ch6LoopBackRemoteread-writecurrent8E1-ET100(T/S) Series card port E1 channel 6 loop back: 0:Off 2:RLB (Max used 4 channels)
1.3.6.1.4.1.4756.20.351.20.1.73Columnfa8e1et100E1Ch7LoopBackRemoteread-writecurrent8E1-ET100(T/S) Series card port E1 channel 7 loop back: 0:Off 2:RLB (Max used 4 channels)
1.3.6.1.4.1.4756.20.351.20.1.74Columnfa8e1et100E1Ch8LoopBackRemoteread-writecurrent8E1-ET100(T/S) Series card port E1 channel 8 loop back: 0:Off 2:RLB (Max used 4 channels)
1.3.6.1.4.1.4756.20.351.20.1.75Columnfa8e1et100FxLinkRemoteread-onlycurrent8E1-ET100S Series card Fiber siganl detect status: 0:Down or Fiber unplugged 1:Up or Singal detected
1.3.6.1.4.1.4756.20.351.20.1.76Columnfa8e1et100FxLaserRemoteread-onlycurrent8E1-ET100S Series card laser status: 0:Normal 1:Error
1.3.6.1.4.1.4756.20.351.20.1.77Columnfa8e1et100FxActiveRemoteread-writecurrent8E1-ET100S Series card Fiber active: 0:Inactive 1:Active
1.3.6.1.4.1.4756.20.351.20.1.78Columnfa8e1et100FxLaserOutputRemoteread-writecurrent8E1-ET100S Series card laser output: 0:disable 1:Enable
1.3.6.1.4.1.4756.20.351.20.1.79Columnfa8e1et100FxOpModeRemoteread-writecurrent8E1-ET100S Series card operation mode: 0:Switch 1:Convert
1.3.6.1.4.1.4756.20.351.20.1.80Columnfa8e1et100UtpLinkRemoteread-onlycurrent8E1-ET100T Series card UTP link status: 0:Link Down 1:Link Up
1.3.6.1.4.1.4756.20.351.20.1.81Columnfa8e1et100UtpStatusRemoteread-onlycurrent8E1-ET100T Series card UTP link mode status: 0:None, Maybe link down 1:Link at 10Mbps, Half duplex 2:Link at 10Mbps, Full duplex 3:Link at 100Mbps, Half duplex…
1.3.6.1.4.1.4756.20.351.20.1.82Columnfa8e1et100UtpFlowCtrlStsRemoteread-onlycurrent8E1-ET100T Series card UTP flow control status: 0:Disable 1:Enable
1.3.6.1.4.1.4756.20.351.20.1.83Columnfa8e1et100UtpModeRemoteread-writecurrent8E1-ET100T Series card UTP mode: 0:Disable 1:Enable and autoNegotiation 3:Enable and force to 10Mbps, Half duplex 4:Enable and force to 10Mbps, Full duplex 5:E…
1.3.6.1.4.1.4756.20.351.20.1.84Columnfa8e1et100UtpFlowCtrlRemoteread-writecurrent8E1-ET100T Series card UTP flow control: 0:Disable 1:Enable
1.3.6.1.4.1.4756.20.351.20.1.85Columnfa8e1et100SpeedLimitRemoteread-writecurrent8E1-ET100(T/S) Series card speed limit: Limited = this value * 32Kbps, this value is restricted to 0 ~ 3125, 0 to disable
1.3.6.1.4.1.4756.20.351.20.1.86Columnfa8e1et100VlanAwareRemoteread-writecurrent8E1-ET100(T/S) Series card 802.1q VLAN tag aware: 0:Disable 1:Enable
1.3.6.1.4.1.4756.20.351.20.1.87Columnfa8e1et100VlanIDRemoteread-writecurrent8E1-ET100(T/S) Series card VLAN ID: The ID is restricted to 1 ~ 4094
1.3.6.1.4.1.4756.20.351.20.1.88Columnfa8e1et100RemoteDeviceRemoteread-onlycurrentFRM220A-8E1 Series card remote device status: 0:Link Down 1:Link Up
1.3.6.1.4.1.4756.20.351.20.1.89Columnfa8e1et100RemotePowerRemoteread-onlycurrent8E1-ET100(T/S) Series card remote device power status: 0:Normal 1:Power off
1.3.6.1.4.1.4756.20.351.20.1.90Columnfa8e1et100TimingSourceRemoteread-writecurrent8E1-ET100(T/S) Series card clock: 0:Internal oscillatro 1:Recovery from E1 channel 1 2:Recovery from E1 channel 2 3:Recovery from E1 channel 3 4:Recovery from …
1.3.6.1.4.1.4756.20.351.20.1.91Columnfa8e1et100FCSofGFPRemoteread-writecurrent8E1-ET100(T/S) Series card FCS of GFP: 0:Disable 1:Enable
1.3.6.1.4.1.4756.20.351.20.1.92Columnfa8e1et100AutoChAdjustRemoteread-writecurrent8E1-ET100(T/S) Series card auto channel Bdjust: 0:Disable 1:Enable
1.3.6.1.4.1.4756.20.351.20.1.93Columnfa8e1et100PayloadScrambleRemoteread-writecurrent8E1-ET100(T/S) Series card payload scramble: 0:Disable 1:Enable
1.3.6.1.4.1.4756.20.351.20.1.94Columnfa8e1et100FailoverRemoteread-writecurrent8E1-ET100(T/S) Series card failover: 0:Disable 1:Enable
1.3.6.1.4.1.4756.20.351.20.1.95Columnfa8e1et100LOMRemoteread-onlycurrent8E1-ET100(T/S) Series card LOM status: 0:No 1:Yes
1.3.6.1.4.1.4756.20.351.20.1.96Columnfa8e1et100SQMRemoteread-onlycurrent8E1-ET100(T/S) Series card SQM status: 0:No 1:Yes
1.3.6.1.4.1.4756.20.351.20.1.97Columnfa8e1et100CRCRemoteread-onlycurrent8E1-ET100(T/S) Series card CRC status: 0:No 1:Yes
1.3.6.1.4.1.4756.20.351.20.1.98Columnfa8e1et100LOARemoteread-onlycurrent8E1-ET100(T/S) Series card LOA status: 0:No 1:Yes
1.3.6.1.4.1.4756.20.351.20.1.99Columnfa8e1et100LFDRemoteread-onlycurrent8E1-ET100(T/S) Series card LFD status: 0:No 1:Yes
1.3.6.1.4.1.4756.20.351.20.1.100Columnfa8e1et100DDTORemoteread-onlycurrent8E1-ET100(T/S) Series card DDTO status: 0:No 1:Yes
1.3.6.1.4.1.4756.20.351.20.1.101Columnfa8e1et100VcatMember1Remoteread-writecurrent8E1-ET100(T/S) Series card VACT member 0: 0:Disable 1:Enable
1.3.6.1.4.1.4756.20.351.20.1.102Columnfa8e1et100VcatMember2Remoteread-writecurrent8E1-ET100(T/S) Series card VACT member 1: 0:Disable 1:Enable
1.3.6.1.4.1.4756.20.351.20.1.103Columnfa8e1et100VcatMember3Remoteread-writecurrent8E1-ET100(T/S) Series card VACT member 3: 0:Disable 1:Enable
1.3.6.1.4.1.4756.20.351.20.1.104Columnfa8e1et100VcatMember4Remoteread-writecurrent8E1-ET100(T/S) Series card VACT member 4: 0:Disable 1:Enable
1.3.6.1.4.1.4756.20.351.20.1.105Columnfa8e1et100VcatMember5Remoteread-writecurrent8E1-ET100(T/S) Series card VACT member 5: 0:Disable 1:Enable
1.3.6.1.4.1.4756.20.351.20.1.106Columnfa8e1et100VcatMember6Remoteread-writecurrent8E1-ET100(T/S) Series card VACT member 6: 0:Disable 1:Enable
1.3.6.1.4.1.4756.20.351.20.1.107Columnfa8e1et100VcatMember7Remoteread-writecurrent8E1-ET100(T/S) Series card VACT member 7: 0:Disable 1:Enable
1.3.6.1.4.1.4756.20.351.20.1.108Columnfa8e1et100VcatMember8Remoteread-writecurrent8E1-ET100(T/S) Series card VACT member 8: 0:Disable 1:Enable
1.3.6.1.4.1.4756.20.351.20.1.109Columnfa8e1et100SnmpChannel1Remoteread-writecurrent8E1-ET100(T/S) Series card SNMP channel 0: 0:No use 1:Use
1.3.6.1.4.1.4756.20.351.20.1.110Columnfa8e1et100SnmpChannel2Remoteread-writecurrent8E1-ET100(T/S) Series card SNMP channel 1: 0:No use 1:Use
1.3.6.1.4.1.4756.20.351.20.1.111Columnfa8e1et100SnmpChannel3Remoteread-writecurrent8E1-ET100(T/S) Series card SNMP channel 3: 0:No use 1:Use
1.3.6.1.4.1.4756.20.351.20.1.112Columnfa8e1et100SnmpChannel4Remoteread-writecurrent8E1-ET100(T/S) Series card SNMP channel 4: 0:No use 1:Use
1.3.6.1.4.1.4756.20.351.20.1.113Columnfa8e1et100ErrSecRemoteread-onlycurrent8E1-ET100(T/S) Series card, errored seconds of BERT result.
1.3.6.1.4.1.4756.20.351.20.1.114Columnfa8e1et100ErrFreeSecRemoteread-onlycurrent8E1-ET100(T/S) Series card, errored free seconds of BERT result.
1.3.6.1.4.1.4756.20.351.20.1.115Columnfa8e1et100ServErrSecRemoteread-onlycurrent8E1-ET100(T/S) Series card, severely errored seconds of BERT result.
1.3.6.1.4.1.4756.20.351.20.1.116Columnfa8e1et100BertFunctionRemoteread-writecurrent8E1-ET100(T/S) Series card bert function: 0:Disable 1:Enable
1.3.6.1.4.1.4756.20.351.20.1.117Columnfa8e1et100ClrBertDataRemoteread-writecurrent8E1-ET100(T/S) Series card bert data clear: 0:Normal 1:Clear
1.3.6.1.4.1.4756.20.351.20.1.118Columnfa8e1et100BertE1ChannelRemoteread-writecurrent8E1-ET100(T/S) Series card bert E1 channel number: 0:E1 channel 1 1:E1 channel 2 2:E1 channel 3 3:E1 channel 4 4:E1 channel 5 5:E1 channel 6 6:E1 channel 7 7:E…
1.3.6.1.4.1.4756.20.351.20.1.119Columnfa8e1et100RmonFunctionRemoteread-writecurrent8E1-ET100(T/S) Series RMON function : 0:Disable 1:Enable
1.3.6.1.4.1.4756.20.351.20.1.120Columnfa8e1et100RmonTxRemoteread-onlycurrent8E1-ET100(T/S) Series card RMON Tx counter.
1.3.6.1.4.1.4756.20.351.20.1.121Columnfa8e1et100RmonRxRemoteread-onlycurrent8E1-ET100(T/S) Series card RMON Rx counter.
1.3.6.1.4.1.4756.20.351.20.1.122Columnfa8e1et100ClrRmonTxRemoteread-writecurrent8E1-ET100(T/S) Series card clear RMON Tx counter: 0:Normal 1:Clear
1.3.6.1.4.1.4756.20.351.20.1.123Columnfa8e1et100ClrRmonRxRemoteread-writecurrent8E1-ET100(T/S) Series card clear RMON Rx counter: 0:Normal 1:Clear
1.3.6.1.4.1.4756.20.351.20.1.124Columnfa8e1et100SfpRemoteread-onlycurrent8E1-ET100(T/S) Series card, SFP existed: 0:No 1:Yes
1.3.6.1.4.1.4756.20.351.20.1.125Columnfa8e1et100SfpVendorRemoteread-onlycurrent8E1-ET100(T/S) Series card, Vendor name of SFP.
1.3.6.1.4.1.4756.20.351.20.1.126Columnfa8e1et100SfpPartNoRemoteread-onlycurrent8E1-ET100(T/S) Series card, Vendor part number of SFP.
1.3.6.1.4.1.4756.20.351.20.1.127Columnfa8e1et100SfpFiberTypeRemoteread-onlycurrent8E1-ET100(T/S) Series card, Fiber Type of SFP.
1.3.6.1.4.1.4756.20.351.20.1.128Columnfa8e1et100SfpTxWaveLenRemoteread-onlycurrent8E1-ET100(T/S) Series card, Tx Wave length of SFP.
1.3.6.1.4.1.4756.20.351.20.1.129Columnfa8e1et100SfpRxWaveLenRemoteread-onlycurrent8E1-ET100(T/S) Series card, Rx Wave length of SFP.
1.3.6.1.4.1.4756.20.351.20.1.130Columnfa8e1et100SfpLinkLenRemoteread-onlycurrent8E1-ET100(T/S) Series card, Link length of SFP.
1.3.6.1.4.1.4756.20.351.20.1.131Columnfa8e1et100SfpModelIDRemoteread-onlycurrent8E1-ET100(T/S) Series card, model ID of SFP.
1.3.6.1.4.1.4756.20.351.20.1.132Columnfa8e1et100SfpVersionRemoteread-onlycurrent8E1-ET100(T/S) Series card, the version of SFP.
1.3.6.1.4.1.4756.20.351.20.1.133Columnfa8e1et100SfpModelTypeRemoteread-onlycurrent8E1-ET100(T/S) Series card, model type of SFP.
1.3.6.1.4.1.4756.20.351.20.1.134Columnfa8e1et100DDInformationRemoteread-onlycurrent8E1-ET100(T/S) Series card, D/D information of SFP Supported: 0:No, 1:Yes
1.3.6.1.4.1.4756.20.351.20.1.135Columnfa8e1et100DDRxSensRemoteread-onlycurrent8E1-ET100(T/S) Series card, Sensitivity of D/D information.
1.3.6.1.4.1.4756.20.351.20.1.136Columnfa8e1et100DDTxPowerRemoteread-onlycurrent8E1-ET100(T/S) Series card, Tx power of D/D information.
1.3.6.1.4.1.4756.20.351.20.1.137Columnfa8e1et100DDRxPowerRemoteread-onlycurrent8E1-ET100(T/S) Series card, Rx power of D/D information.
1.3.6.1.4.1.4756.20.351.20.1.138Columnfa8e1et100DDTempRemoteread-onlycurrent8E1-ET100(T/S) Series card, Temperature of D/D information in degree C.
1.3.6.1.4.1.4756.20.351.20.1.139Columnfa8e1et100DDBiasRemoteread-onlycurrent8E1-ET100(T/S) Series card, BIAS of D/D information.
1.3.6.1.4.1.4756.20.351.20.1.140Columnfa8e1et100DDVoltageRemoteread-onlycurrent8E1-ET100(T/S) Series card, Voltage of D/D information.
1.3.6.1.4.1.4756.20.351.20.1.141Columnfa8e1et100ChannelDefectRemoteread-writecurrent8E1-ET100(T/S) Series card Channel Defect: 0:Disable 4:1E-4 6:1E-6
1.3.6.1.4.1.4756.20.351.20.1.142Columnfa8e1et100LoopDetectionRemoteread-writecurrent8E1-ET100(T/S) Series card Loop Detection: 0:Disable 1:Enable
1.3.6.1.4.1.4756.20.351.20.1.143Columnfa8e1et100LoopCh1Remoteread-onlycurrent8E1-ET100(T/S) Series card E1 channel 1 Loop Check State: 0:No 1:Yes
1.3.6.1.4.1.4756.20.351.20.1.144Columnfa8e1et100LoopCh2Remoteread-onlycurrent8E1-ET100(T/S) Series card E1 channel 2 Loop Check State: 0:No 1:Yes
1.3.6.1.4.1.4756.20.351.20.1.145Columnfa8e1et100LoopCh3Remoteread-onlycurrent8E1-ET100(T/S) Series card E1 channel 3 Loop Check State: 0:No 1:Yes
1.3.6.1.4.1.4756.20.351.20.1.146Columnfa8e1et100LoopCh4Remoteread-onlycurrent8E1-ET100(T/S) Series card E1 channel 4 Loop Check State: 0:No 1:Yes
1.3.6.1.4.1.4756.20.351.20.1.147Columnfa8e1et100LoopCh5Remoteread-onlycurrent8E1-ET100(T/S) Series card E1 channel 5 Loop Check State: 0:No 1:Yes
1.3.6.1.4.1.4756.20.351.20.1.148Columnfa8e1et100LoopCh6Remoteread-onlycurrent8E1-ET100(T/S) Series card E1 channel 6 Loop Check State: 0:No 1:Yes
1.3.6.1.4.1.4756.20.351.20.1.149Columnfa8e1et100LoopCh7Remoteread-onlycurrent8E1-ET100(T/S) Series card E1 channel 7 Loop Check State: 0:No 1:Yes
1.3.6.1.4.1.4756.20.351.20.1.150Columnfa8e1et100LoopCh8Remoteread-onlycurrent8E1-ET100(T/S) Series card E1 channel 8 Loop Check State: 0:No 1:Yes
1.3.6.1.4.1.4756.20.351.20.1.151Columnfa8e1et100DefectCh1Remoteread-onlycurrent8E1-ET100(T/S) Series card E1 channel 1 Defect Status: 0:No 1:Yes
1.3.6.1.4.1.4756.20.351.20.1.152Columnfa8e1et100DefectCh2Remoteread-onlycurrent8E1-ET100(T/S) Series card E1 channel 2 Defect Status: 0:No 1:Yes
1.3.6.1.4.1.4756.20.351.20.1.153Columnfa8e1et100DefectCh3Remoteread-onlycurrent8E1-ET100(T/S) Series card E1 channel 3 Defect Status: 0:No 1:Yes
1.3.6.1.4.1.4756.20.351.20.1.154Columnfa8e1et100DefectCh4Remoteread-onlycurrent8E1-ET100(T/S) Series card E1 channel 4 Defect Status: 0:No 1:Yes
1.3.6.1.4.1.4756.20.351.20.1.155Columnfa8e1et100DefectCh5Remoteread-onlycurrent8E1-ET100(T/S) Series card E1 channel 5 Defect Status: 0:No 1:Yes
1.3.6.1.4.1.4756.20.351.20.1.156Columnfa8e1et100DefectCh6Remoteread-onlycurrent8E1-ET100(T/S) Series card E1 channel 6 Defect Status: 0:No 1:Yes
1.3.6.1.4.1.4756.20.351.20.1.157Columnfa8e1et100DefectCh7Remoteread-onlycurrent8E1-ET100(T/S) Series card E1 channel 7 Defect Status: 0:No 1:Yes
1.3.6.1.4.1.4756.20.351.20.1.158Columnfa8e1et100DefectCh8Remoteread-onlycurrent8E1-ET100(T/S) Series card E1 channel 8 Defect Status: 0:No 1:Yes
1.3.6.1.4.1.4756.20.351.20.1.159Columnfa8e1et100FxSignalRemoteread-onlycurrent8E1-ET100(T/S) Series card Fiber signal detect(SD): 0:Fiber unplugged 1:Signal detected
1.3.6.1.4.1.4756.20.351.20.1.160Columnfa8e1et100PortResetRemoteread-writecurrent8E1-ET100(T/S) Series card Port Reset: 0:Action 1:Off
1.3.6.1.4.1.4756.20.351.20.1.161Columnfa8e1et100VLANModeRemoteread-writecurrent8E1-ET100(T/S) Series card VLAN mode: 0:MODE2 1:MODE1
1.3.6.1.4.1.4756.20.351.20.1.162Columnfa8e1et100ETagSelectEntryRemoteread-writecurrent8E1-ET100(T/S) Series card ETag select entry:
1.3.6.1.4.1.4756.20.351.20.1.163Columnfa8e1et100ETagMethodRemoteread-writecurrent8E1-ET100(T/S) Series card ETag Method: 0: Intouch 1: Add Tag 2: Remove Tag
1.3.6.1.4.1.4756.20.351.20.1.164Columnfa8e1et100VLANTableVID1Remoteread-writecurrent8E1-ET100(T/S) Series card VLAN Table: VLAN ID1
1.3.6.1.4.1.4756.20.351.20.1.165Columnfa8e1et100VLANTableVID2Remoteread-writecurrent8E1-ET100(T/S) Series card VLAN Table: VLAN ID2
1.3.6.1.4.1.4756.20.351.20.1.166Columnfa8e1et100VLANTableVID3Remoteread-writecurrent8E1-ET100(T/S) Series card VLAN Table: VLAN ID3
1.3.6.1.4.1.4756.20.351.20.1.167Columnfa8e1et100VLANTableVID4Remoteread-writecurrent8E1-ET100(T/S) Series card VLAN Table: VLAN ID4
1.3.6.1.4.1.4756.20.351.20.1.168Columnfa8e1et100VLANTableVID5Remoteread-writecurrent8E1-ET100(T/S) Series card VLAN Table: VLAN ID5
1.3.6.1.4.1.4756.20.351.20.1.169Columnfa8e1et100VLANTableVID6Remoteread-writecurrent8E1-ET100(T/S) Series card VLAN Table: VLAN ID6
1.3.6.1.4.1.4756.20.351.20.1.170Columnfa8e1et100VLANTableVID7Remoteread-writecurrent8E1-ET100(T/S) Series card VLAN Table: VLAN ID7
1.3.6.1.4.1.4756.20.351.20.1.171Columnfa8e1et100VLANTableVID8Remoteread-writecurrent8E1-ET100(T/S) Series card VLAN Table: VLAN ID8
1.3.6.1.4.1.4756.20.351.20.1.172Columnfa8e1et100VLANTableVID9Remoteread-writecurrent8E1-ET100(T/S) Series card VLAN Table: VLAN ID9
1.3.6.1.4.1.4756.20.351.20.1.173Columnfa8e1et100VLANTableVID10Remoteread-writecurrent8E1-ET100(T/S) Series card VLAN Table: VLAN ID10
1.3.6.1.4.1.4756.20.351.20.1.174Columnfa8e1et100VLANTableVID11Remoteread-writecurrent8E1-ET100(T/S) Series card VLAN Table: VLAN ID11
1.3.6.1.4.1.4756.20.351.20.1.175Columnfa8e1et100VLANTableVID12Remoteread-writecurrent8E1-ET100(T/S) Series card VLAN Table: VLAN ID12
1.3.6.1.4.1.4756.20.351.20.1.176Columnfa8e1et100VLANTableVID13Remoteread-writecurrent8E1-ET100(T/S) Series card VLAN Table: VLAN ID13
1.3.6.1.4.1.4756.20.351.20.1.177Columnfa8e1et100VLANTableVID14Remoteread-writecurrent8E1-ET100(T/S) Series card VLAN Table: VLAN ID14
1.3.6.1.4.1.4756.20.351.20.1.178Columnfa8e1et100VLANTableVID15Remoteread-writecurrent8E1-ET100(T/S) Series card VLAN Table: VLAN ID15
1.3.6.1.4.1.4756.20.351.20.1.179Columnfa8e1et100VLANTableVID16Remoteread-writecurrent8E1-ET100(T/S) Series card VLAN Table: VLAN ID16
1.3.6.1.4.1.4756.20.360Nodef16E1LocalCards
1.3.6.1.4.1.4756.20.360.20Tablef16E1LocalTablenot-accessiblecurrentA list of local FRM220-16E1-ET100 series card entries. The number of entries is f16E1-No-L.
1.3.6.1.4.1.4756.20.360.20.1Rowf16E1LocalEntrynot-accessiblecurrentAn entry containing management information applicable to a particular local FRM220-16E1 series card.
1.3.6.1.4.1.4756.20.360.20.1.1Columnfa16e1et100ChassisIndexLocalread-onlycurrentA unique value for each card. It starts from 0 to 9 contiguously.
1.3.6.1.4.1.4756.20.360.20.1.2Columnfa16e1et100SlotIndexLocalread-onlycurrentA unique value for each card. It starts from 1 to 20 contiguously.
1.3.6.1.4.1.4756.20.360.20.1.3Columnfa16e1et100CardHWVerLocalread-onlycurrent16E1-ET100(T/S) Series card hardware version x.xxx
1.3.6.1.4.1.4756.20.360.20.1.4Columnfa16e1et100CardFWVerLocalread-onlycurrent16E1-ET100(T/S) Series card firmware version x.xxx
1.3.6.1.4.1.4756.20.360.20.1.5Columnfa16e1et100CardCPLDVerLocalread-onlycurrent16E1-ET100(T/S) Series card CPLD version x.xxx
1.3.6.1.4.1.4756.20.360.20.1.6Columnfa16e1et100CardFPGAVerLocalread-onlycurrent16E1-ET100(T/S) Series card FPGA version x.xxx
1.3.6.1.4.1.4756.20.360.20.1.7Columnfa16e1et100ModelLocalread-onlycurrentCard Type: 0:16E1-ET100T 1:16E1-ET100S
1.3.6.1.4.1.4756.20.360.20.1.8Columnfa16e1et100SystemStatusLocalread-onlycurrent16E1-ET100(T/S) Series card system status: 0:Normal 1:Alarm
1.3.6.1.4.1.4756.20.360.20.1.9Columnfa16e1et100DeviceActiveLocalread-writecurrent16E1-ET100(T/S) Series card active: 0:Disable 1:Enable
1.3.6.1.4.1.4756.20.360.20.1.10Columnfa16e1et100SetToDefaultLocalread-writecurrent16E1-ET100(T/S) Series card port set to default: 0:Off 1:Trigger
1.3.6.1.4.1.4756.20.360.20.1.11Columnfa16e1et100E1Ch1SingalLocalread-onlycurrent16E1-ET100(T/S) Series card E1 channel 1 signal status: 0:Singal Loss 1:Normal
1.3.6.1.4.1.4756.20.360.20.1.12Columnfa16e1et100E1Ch2SingalLocalread-onlycurrent16E1-ET100(T/S) Series card E1 channel 2 signal status: 0:Singal Loss 1:Normal
1.3.6.1.4.1.4756.20.360.20.1.13Columnfa16e1et100E1Ch3SingalLocalread-onlycurrent16E1-ET100(T/S) Series card E1 channel 3 signal status: 0:Singal Loss 1:Normal
1.3.6.1.4.1.4756.20.360.20.1.14Columnfa16e1et100E1Ch4SingalLocalread-onlycurrent16E1-ET100(T/S) Series card E1 channel 4 signal status: 0:Singal Loss 1:Normal
1.3.6.1.4.1.4756.20.360.20.1.15Columnfa16e1et100E1Ch5SingalLocalread-onlycurrent16E1-ET100(T/S) Series card E1 channel 5 signal status: 0:Singal Loss 1:Normal
1.3.6.1.4.1.4756.20.360.20.1.16Columnfa16e1et100E1Ch6SingalLocalread-onlycurrent16E1-ET100(T/S) Series card E1 channel 6 signal status: 0:Singal Loss 1:Normal
1.3.6.1.4.1.4756.20.360.20.1.17Columnfa16e1et100E1Ch7SingalLocalread-onlycurrent16E1-ET100(T/S) Series card E1 channel 7 signal status: 0:Singal Loss 1:Normal
1.3.6.1.4.1.4756.20.360.20.1.18Columnfa16e1et100E1Ch8SingalLocalread-onlycurrent16E1-ET100(T/S) Series card E1 channel 8 signal status: 0:Singal Loss 1:Normal
1.3.6.1.4.1.4756.20.360.20.1.19Columnfa16e1et100E1Ch9SingalLocalread-onlycurrent16E1-ET100(T/S) Series card E1 channel 9 signal status: 0:Singal Loss 1:Normal
1.3.6.1.4.1.4756.20.360.20.1.20Columnfa16e1et100E1Ch10SingalLocalread-onlycurrent16E1-ET100(T/S) Series card E1 channel 10 signal status: 0:Singal Loss 1:Normal
1.3.6.1.4.1.4756.20.360.20.1.21Columnfa16e1et100E1Ch11SingalLocalread-onlycurrent16E1-ET100(T/S) Series card E1 channel 11 signal status: 0:Singal Loss 1:Normal
1.3.6.1.4.1.4756.20.360.20.1.22Columnfa16e1et100E1Ch12SingalLocalread-onlycurrent16E1-ET100(T/S) Series card E1 channel 12 signal status: 0:Singal Loss 1:Normal
1.3.6.1.4.1.4756.20.360.20.1.23Columnfa16e1et100E1Ch13SingalLocalread-onlycurrent16E1-ET100(T/S) Series card E1 channel 13 signal status: 0:Singal Loss 1:Normal
1.3.6.1.4.1.4756.20.360.20.1.24Columnfa16e1et100E1Ch14SingalLocalread-onlycurrent16E1-ET100(T/S) Series card E1 channel 14 signal status: 0:Singal Loss 1:Normal
1.3.6.1.4.1.4756.20.360.20.1.25Columnfa16e1et100E1Ch15SingalLocalread-onlycurrent16E1-ET100(T/S) Series card E1 channel 15 signal status: 0:Singal Loss 1:Normal
1.3.6.1.4.1.4756.20.360.20.1.26Columnfa16e1et100E1Ch16SingalLocalread-onlycurrent16E1-ET100(T/S) Series card E1 channel 16 signal status: 0:Singal Loss 1:Normal
1.3.6.1.4.1.4756.20.360.20.1.27Columnfa16e1et100E1Ch1SyncLocalread-onlycurrent16E1-ET100(T/S) Series card E1 channel 1 sync status: 0:Sync Loss 1:Sync
1.3.6.1.4.1.4756.20.360.20.1.28Columnfa16e1et100E1Ch2SyncLocalread-onlycurrent16E1-ET100(T/S) Series card E1 channel 2 sync status: 0:Sync Loss 1:Sync
1.3.6.1.4.1.4756.20.360.20.1.29Columnfa16e1et100E1Ch3SyncLocalread-onlycurrent16E1-ET100(T/S) Series card E1 channel 3 sync status: 0:Sync Loss 1:Sync
1.3.6.1.4.1.4756.20.360.20.1.30Columnfa16e1et100E1Ch4SyncLocalread-onlycurrent16E1-ET100(T/S) Series card E1 channel 4 sync status: 0:Sync Loss 1:Sync
1.3.6.1.4.1.4756.20.360.20.1.31Columnfa16e1et100E1Ch5SyncLocalread-onlycurrent16E1-ET100(T/S) Series card E1 channel 5 sync status: 0:Sync Loss 1:Sync
1.3.6.1.4.1.4756.20.360.20.1.32Columnfa16e1et100E1Ch6SyncLocalread-onlycurrent16E1-ET100(T/S) Series card E1 channel 6 sync status: 0:Sync Loss 1:Sync
1.3.6.1.4.1.4756.20.360.20.1.33Columnfa16e1et100E1Ch7SyncLocalread-onlycurrent16E1-ET100(T/S) Series card E1 channel 7 sync status: 0:Sync Loss 1:Sync
1.3.6.1.4.1.4756.20.360.20.1.34Columnfa16e1et100E1Ch8SyncLocalread-onlycurrent16E1-ET100(T/S) Series card E1 channel 8 sync status: 0:Sync Loss 1:Sync
1.3.6.1.4.1.4756.20.360.20.1.35Columnfa16e1et100E1Ch9SyncLocalread-onlycurrent16E1-ET100(T/S) Series card E1 channel 9 sync status: 0:Sync Loss 1:Sync
1.3.6.1.4.1.4756.20.360.20.1.36Columnfa16e1et100E1Ch10SyncLocalread-onlycurrent16E1-ET100(T/S) Series card E1 channel 10 sync status: 0:Sync Loss 1:Sync
1.3.6.1.4.1.4756.20.360.20.1.37Columnfa16e1et100E1Ch11SyncLocalread-onlycurrent16E1-ET100(T/S) Series card E1 channel 11 sync status: 0:Sync Loss 1:Sync
1.3.6.1.4.1.4756.20.360.20.1.38Columnfa16e1et100E1Ch12SyncLocalread-onlycurrent16E1-ET100(T/S) Series card E1 channel 12 sync status: 0:Sync Loss 1:Sync
1.3.6.1.4.1.4756.20.360.20.1.39Columnfa16e1et100E1Ch13SyncLocalread-onlycurrent16E1-ET100(T/S) Series card E1 channel 13 sync status: 0:Sync Loss 1:Sync
1.3.6.1.4.1.4756.20.360.20.1.40Columnfa16e1et100E1Ch14SyncLocalread-onlycurrent16E1-ET100(T/S) Series card E1 channel 14 sync status: 0:Sync Loss 1:Sync
1.3.6.1.4.1.4756.20.360.20.1.41Columnfa16e1et100E1Ch15SyncLocalread-onlycurrent16E1-ET100(T/S) Series card E1 channel 15 sync status: 0:Sync Loss 1:Sync
1.3.6.1.4.1.4756.20.360.20.1.42Columnfa16e1et100E1Ch16SyncLocalread-onlycurrent16E1-ET100(T/S) Series card E1 channel 16 sync status: 0:Sync Loss 1:Sync
1.3.6.1.4.1.4756.20.360.20.1.43Columnfa16e1et100E1Ch1RecvAISLocalread-onlycurrent16E1-ET100(T/S) Series card E1 channel 1 receive AIS status: 0:No 1:Yes
1.3.6.1.4.1.4756.20.360.20.1.44Columnfa16e1et100E1Ch2RecvAISLocalread-onlycurrent16E1-ET100(T/S) Series card E1 channel 2 receive AIS status: 0:No 1:Yes
1.3.6.1.4.1.4756.20.360.20.1.45Columnfa16e1et100E1Ch3RecvAISLocalread-onlycurrent16E1-ET100(T/S) Series card E1 channel 3 receive AIS status: 0:No 1:Yes
1.3.6.1.4.1.4756.20.360.20.1.46Columnfa16e1et100E1Ch4RecvAISLocalread-onlycurrent16E1-ET100(T/S) Series card E1 channel 4 receive AIS status: 0:No 1:Yes
1.3.6.1.4.1.4756.20.360.20.1.47Columnfa16e1et100E1Ch5RecvAISLocalread-onlycurrent16E1-ET100(T/S) Series card E1 channel 5 receive AIS status: 0:No 1:Yes
1.3.6.1.4.1.4756.20.360.20.1.48Columnfa16e1et100E1Ch6RecvAISLocalread-onlycurrent16E1-ET100(T/S) Series card E1 channel 6 receive AIS status: 0:No 1:Yes
1.3.6.1.4.1.4756.20.360.20.1.49Columnfa16e1et100E1Ch7RecvAISLocalread-onlycurrent16E1-ET100(T/S) Series card E1 channel 7 receive AIS status: 0:No 1:Yes
1.3.6.1.4.1.4756.20.360.20.1.50Columnfa16e1et100E1Ch8RecvAISLocalread-onlycurrent16E1-ET100(T/S) Series card E1 channel 8 receive AIS status: 0:No 1:Yes
1.3.6.1.4.1.4756.20.360.20.1.51Columnfa16e1et100E1Ch9RecvAISLocalread-onlycurrent16E1-ET100(T/S) Series card E1 channel 9 receive AIS status: 0:No 1:Yes
1.3.6.1.4.1.4756.20.360.20.1.52Columnfa16e1et100E1Ch10RecvAISLocalread-onlycurrent16E1-ET100(T/S) Series card E1 channel 10 receive AIS status: 0:No 1:Yes
1.3.6.1.4.1.4756.20.360.20.1.53Columnfa16e1et100E1Ch11RecvAISLocalread-onlycurrent16E1-ET100(T/S) Series card E1 channel 11 receive AIS status: 0:No 1:Yes
1.3.6.1.4.1.4756.20.360.20.1.54Columnfa16e1et100E1Ch12RecvAISLocalread-onlycurrent16E1-ET100(T/S) Series card E1 channel 12 receive AIS status: 0:No 1:Yes
1.3.6.1.4.1.4756.20.360.20.1.55Columnfa16e1et100E1Ch13RecvAISLocalread-onlycurrent16E1-ET100(T/S) Series card E1 channel 13 receive AIS status: 0:No 1:Yes
1.3.6.1.4.1.4756.20.360.20.1.56Columnfa16e1et100E1Ch14RecvAISLocalread-onlycurrent16E1-ET100(T/S) Series card E1 channel 14 receive AIS status: 0:No 1:Yes
1.3.6.1.4.1.4756.20.360.20.1.57Columnfa16e1et100E1Ch15RecvAISLocalread-onlycurrent16E1-ET100(T/S) Series card E1 channel 15 receive AIS status: 0:No 1:Yes
1.3.6.1.4.1.4756.20.360.20.1.58Columnfa16e1et100E1Ch16RecvAISLocalread-onlycurrent16E1-ET100(T/S) Series card E1 channel 16 receive AIS status: 0:No 1:Yes
1.3.6.1.4.1.4756.20.360.20.1.59Columnfa16e1et100E1Ch1ConnTypeLocalread-onlycurrent16E1-ET100(T/S) Series card E1 channel 1 connector type: 0:RJ-48C 1:BNC
1.3.6.1.4.1.4756.20.360.20.1.60Columnfa16e1et100E1Ch2ConnTypeLocalread-onlycurrent16E1-ET100(T/S) Series card E1 channel 2 connector type: 0:RJ-48C 1:BNC
1.3.6.1.4.1.4756.20.360.20.1.61Columnfa16e1et100E1Ch3ConnTypeLocalread-onlycurrent16E1-ET100(T/S) Series card E1 channel 3 connector type: 0:RJ-48C 1:BNC
1.3.6.1.4.1.4756.20.360.20.1.62Columnfa16e1et100E1Ch4ConnTypeLocalread-onlycurrent16E1-ET100(T/S) Series card E1 channel 4 connector type: 0:RJ-48C 1:BNC
1.3.6.1.4.1.4756.20.360.20.1.63Columnfa16e1et100E1Ch5ConnTypeLocalread-onlycurrent16E1-ET100(T/S) Series card E1 channel 5 connector type: 0:RJ-48C 1:BNC
1.3.6.1.4.1.4756.20.360.20.1.64Columnfa16e1et100E1Ch6ConnTypeLocalread-onlycurrent16E1-ET100(T/S) Series card E1 channel 6 connector type: 0:RJ-48C 1:BNC
1.3.6.1.4.1.4756.20.360.20.1.65Columnfa16e1et100E1Ch7ConnTypeLocalread-onlycurrent16E1-ET100(T/S) Series card E1 channel 7 connector type: 0:RJ-48C 1:BNC
1.3.6.1.4.1.4756.20.360.20.1.66Columnfa16e1et100E1Ch8ConnTypeLocalread-onlycurrent16E1-ET100(T/S) Series card E1 channel 8 connector type: 0:RJ-48C 1:BNC
1.3.6.1.4.1.4756.20.360.20.1.67Columnfa16e1et100E1Ch9ConnTypeLocalread-onlycurrent16E1-ET100(T/S) Series card E1 channel 9 connector type: 0:RJ-48C 1:BNC
1.3.6.1.4.1.4756.20.360.20.1.68Columnfa16e1et100E1Ch10ConnTypeLocalread-onlycurrent16E1-ET100(T/S) Series card E1 channel 10 connector type: 0:RJ-48C 1:BNC
1.3.6.1.4.1.4756.20.360.20.1.69Columnfa16e1et100E1Ch11ConnTypeLocalread-onlycurrent16E1-ET100(T/S) Series card E1 channel 11 connector type: 0:RJ-48C 1:BNC
1.3.6.1.4.1.4756.20.360.20.1.70Columnfa16e1et100E1Ch12ConnTypeLocalread-onlycurrent16E1-ET100(T/S) Series card E1 channel 12 connector type: 0:RJ-48C 1:BNC
1.3.6.1.4.1.4756.20.360.20.1.71Columnfa16e1et100E1Ch13ConnTypeLocalread-onlycurrent16E1-ET100(T/S) Series card E1 channel 13 connector type: 0:RJ-48C 1:BNC
1.3.6.1.4.1.4756.20.360.20.1.72Columnfa16e1et100E1Ch14ConnTypeLocalread-onlycurrent16E1-ET100(T/S) Series card E1 channel 14 connector type: 0:RJ-48C 1:BNC
1.3.6.1.4.1.4756.20.360.20.1.73Columnfa16e1et100E1Ch15ConnTypeLocalread-onlycurrent16E1-ET100(T/S) Series card E1 channel 15 connector type: 0:RJ-48C 1:BNC
1.3.6.1.4.1.4756.20.360.20.1.74Columnfa16e1et100E1Ch16ConnTypeLocalread-onlycurrent16E1-ET100(T/S) Series card E1 channel 16 connector type: 0:RJ-48C 1:BNC
1.3.6.1.4.1.4756.20.360.20.1.75Columnfa16e1et100E1Ch1RAILocalread-onlycurrent16E1-ET100(T/S) Series card E1 channel 1 RAI status: 0:No 1:Yes
1.3.6.1.4.1.4756.20.360.20.1.76Columnfa16e1et100E1Ch2RAILocalread-onlycurrent16E1-ET100(T/S) Series card E1 channel 2 RAI status: 0:No 1:Yes
1.3.6.1.4.1.4756.20.360.20.1.77Columnfa16e1et100E1Ch3RAILocalread-onlycurrent16E1-ET100(T/S) Series card E1 channel 3 RAI status: 0:No 1:Yes
1.3.6.1.4.1.4756.20.360.20.1.78Columnfa16e1et100E1Ch4RAILocalread-onlycurrent16E1-ET100(T/S) Series card E1 channel 4 RAI status: 0:No 1:Yes
1.3.6.1.4.1.4756.20.360.20.1.79Columnfa16e1et100E1Ch5RAILocalread-onlycurrent16E1-ET100(T/S) Series card E1 channel 5 RAI status: 0:No 1:Yes
1.3.6.1.4.1.4756.20.360.20.1.80Columnfa16e1et100E1Ch6RAILocalread-onlycurrent16E1-ET100(T/S) Series card E1 channel 6 RAI status: 0:No 1:Yes
1.3.6.1.4.1.4756.20.360.20.1.81Columnfa16e1et100E1Ch7RAILocalread-onlycurrent16E1-ET100(T/S) Series card E1 channel 7 RAI status: 0:No 1:Yes
1.3.6.1.4.1.4756.20.360.20.1.82Columnfa16e1et100E1Ch8RAILocalread-onlycurrent16E1-ET100(T/S) Series card E1 channel 8 RAI status: 0:No 1:Yes
1.3.6.1.4.1.4756.20.360.20.1.83Columnfa16e1et100E1Ch9RAILocalread-onlycurrent16E1-ET100(T/S) Series card E1 channel 9 RAI status: 0:No 1:Yes
1.3.6.1.4.1.4756.20.360.20.1.84Columnfa16e1et100E1Ch10RAILocalread-onlycurrent16E1-ET100(T/S) Series card E1 channel 10 RAI status: 0:No 1:Yes
1.3.6.1.4.1.4756.20.360.20.1.85Columnfa16e1et100E1Ch11RAILocalread-onlycurrent16E1-ET100(T/S) Series card E1 channel 11 RAI status: 0:No 1:Yes
1.3.6.1.4.1.4756.20.360.20.1.86Columnfa16e1et100E1Ch12RAILocalread-onlycurrent16E1-ET100(T/S) Series card E1 channel 12 RAI status: 0:No 1:Yes
1.3.6.1.4.1.4756.20.360.20.1.87Columnfa16e1et100E1Ch13RAILocalread-onlycurrent16E1-ET100(T/S) Series card E1 channel 13 RAI status: 0:No 1:Yes
1.3.6.1.4.1.4756.20.360.20.1.88Columnfa16e1et100E1Ch14RAILocalread-onlycurrent16E1-ET100(T/S) Series card E1 channel 14 RAI status: 0:No 1:Yes
1.3.6.1.4.1.4756.20.360.20.1.89Columnfa16e1et100E1Ch15RAILocalread-onlycurrent16E1-ET100(T/S) Series card E1 channel 15 RAI status: 0:No 1:Yes
1.3.6.1.4.1.4756.20.360.20.1.90Columnfa16e1et100E1Ch16RAILocalread-onlycurrent16E1-ET100(T/S) Series card E1 channel 16 RAI status: 0:No 1:Yes
1.3.6.1.4.1.4756.20.360.20.1.91Columnfa16e1et100E1Ch1LOMFLocalread-onlycurrent16E1-ET100(T/S) Series card E1 channel 1 LOMF status: 0:No 1:Yes
1.3.6.1.4.1.4756.20.360.20.1.92Columnfa16e1et100E1Ch2LOMFLocalread-onlycurrent16E1-ET100(T/S) Series card E1 channel 2 LOMF status: 0:No 1:Yes
1.3.6.1.4.1.4756.20.360.20.1.93Columnfa16e1et100E1Ch3LOMFLocalread-onlycurrent16E1-ET100(T/S) Series card E1 channel 3 LOMF status: 0:No 1:Yes
1.3.6.1.4.1.4756.20.360.20.1.94Columnfa16e1et100E1Ch4LOMFLocalread-onlycurrent16E1-ET100(T/S) Series card E1 channel 4 LOMF status: 0:No 1:Yes
1.3.6.1.4.1.4756.20.360.20.1.95Columnfa16e1et100E1Ch5LOMFLocalread-onlycurrent16E1-ET100(T/S) Series card E1 channel 5 LOMF status: 0:No 1:Yes
1.3.6.1.4.1.4756.20.360.20.1.96Columnfa16e1et100E1Ch6LOMFLocalread-onlycurrent16E1-ET100(T/S) Series card E1 channel 6 LOMF status: 0:No 1:Yes
1.3.6.1.4.1.4756.20.360.20.1.97Columnfa16e1et100E1Ch7LOMFLocalread-onlycurrent16E1-ET100(T/S) Series card E1 channel 7 LOMF status: 0:No 1:Yes
1.3.6.1.4.1.4756.20.360.20.1.98Columnfa16e1et100E1Ch8LOMFLocalread-onlycurrent16E1-ET100(T/S) Series card E1 channel 8 LOMF status: 0:No 1:Yes
1.3.6.1.4.1.4756.20.360.20.1.99Columnfa16e1et100E1Ch9LOMFLocalread-onlycurrent16E1-ET100(T/S) Series card E1 channel 9 LOMF status: 0:No 1:Yes
1.3.6.1.4.1.4756.20.360.20.1.100Columnfa16e1et100E1Ch10LOMFLocalread-onlycurrent16E1-ET100(T/S) Series card E1 channel 10 LOMF status: 0:No 1:Yes
1.3.6.1.4.1.4756.20.360.20.1.101Columnfa16e1et100E1Ch11LOMFLocalread-onlycurrent16E1-ET100(T/S) Series card E1 channel 11 LOMF status: 0:No 1:Yes
1.3.6.1.4.1.4756.20.360.20.1.102Columnfa16e1et100E1Ch12LOMFLocalread-onlycurrent16E1-ET100(T/S) Series card E1 channel 12 LOMF status: 0:No 1:Yes
1.3.6.1.4.1.4756.20.360.20.1.103Columnfa16e1et100E1Ch13LOMFLocalread-onlycurrent16E1-ET100(T/S) Series card E1 channel 13 LOMF status: 0:No 1:Yes
1.3.6.1.4.1.4756.20.360.20.1.104Columnfa16e1et100E1Ch14LOMFLocalread-onlycurrent16E1-ET100(T/S) Series card E1 channel 14 LOMF status: 0:No 1:Yes
1.3.6.1.4.1.4756.20.360.20.1.105Columnfa16e1et100E1Ch15LOMFLocalread-onlycurrent16E1-ET100(T/S) Series card E1 channel 15 LOMF status: 0:No 1:Yes
1.3.6.1.4.1.4756.20.360.20.1.106Columnfa16e1et100E1Ch16LOMFLocalread-onlycurrent16E1-ET100(T/S) Series card E1 channel 16 LOMF status: 0:No 1:Yes
1.3.6.1.4.1.4756.20.360.20.1.107Columnfa16e1et100E1Ch1ActiveLocalread-onlycurrent16E1-ET100(T/S) Series card E1 channel 1 active status: 0:Inactive 1:Active
1.3.6.1.4.1.4756.20.360.20.1.108Columnfa16e1et100E1Ch2ActiveLocalread-onlycurrent16E1-ET100(T/S) Series card E1 channel 2 active status: 0:Inactive 1:Active
1.3.6.1.4.1.4756.20.360.20.1.109Columnfa16e1et100E1Ch3ActiveLocalread-onlycurrent16E1-ET100(T/S) Series card E1 channel 3 active status: 0:Inactive 1:Active
1.3.6.1.4.1.4756.20.360.20.1.110Columnfa16e1et100E1Ch4ActiveLocalread-onlycurrent16E1-ET100(T/S) Series card E1 channel 4 active status: 0:Inactive 1:Active
1.3.6.1.4.1.4756.20.360.20.1.111Columnfa16e1et100E1Ch5ActiveLocalread-onlycurrent16E1-ET100(T/S) Series card E1 channel 5 active status: 0:Inactive 1:Active
1.3.6.1.4.1.4756.20.360.20.1.112Columnfa16e1et100E1Ch6ActiveLocalread-onlycurrent16E1-ET100(T/S) Series card E1 channel 6 active status: 0:Inactive 1:Active
1.3.6.1.4.1.4756.20.360.20.1.113Columnfa16e1et100E1Ch7ActiveLocalread-onlycurrent16E1-ET100(T/S) Series card E1 channel 7 active status: 0:Inactive 1:Active
1.3.6.1.4.1.4756.20.360.20.1.114Columnfa16e1et100E1Ch8ActiveLocalread-onlycurrent16E1-ET100(T/S) Series card E1 channel 8 active status: 0:Inactive 1:Active
1.3.6.1.4.1.4756.20.360.20.1.115Columnfa16e1et100E1Ch9ActiveLocalread-onlycurrent16E1-ET100(T/S) Series card E1 channel 9 active status: 0:Inactive 1:Active
1.3.6.1.4.1.4756.20.360.20.1.116Columnfa16e1et100E1Ch10ActiveLocalread-onlycurrent16E1-ET100(T/S) Series card E1 channel 10 active status: 0:Inactive 1:Active
1.3.6.1.4.1.4756.20.360.20.1.117Columnfa16e1et100E1Ch11ActiveLocalread-onlycurrent16E1-ET100(T/S) Series card E1 channel 11 active status: 0:Inactive 1:Active
1.3.6.1.4.1.4756.20.360.20.1.118Columnfa16e1et100E1Ch12ActiveLocalread-onlycurrent16E1-ET100(T/S) Series card E1 channel 12 active status: 0:Inactive 1:Active
1.3.6.1.4.1.4756.20.360.20.1.119Columnfa16e1et100E1Ch13ActiveLocalread-onlycurrent16E1-ET100(T/S) Series card E1 channel 13 active status: 0:Inactive 1:Active
1.3.6.1.4.1.4756.20.360.20.1.120Columnfa16e1et100E1Ch14ActiveLocalread-onlycurrent16E1-ET100(T/S) Series card E1 channel 14 active status: 0:Inactive 1:Active
1.3.6.1.4.1.4756.20.360.20.1.121Columnfa16e1et100E1Ch15ActiveLocalread-onlycurrent16E1-ET100(T/S) Series card E1 channel 15 active status: 0:Inactive 1:Active
1.3.6.1.4.1.4756.20.360.20.1.122Columnfa16e1et100E1Ch16ActiveLocalread-onlycurrent16E1-ET100(T/S) Series card E1 channel 16 active status: 0:Inactive 1:Active
1.3.6.1.4.1.4756.20.360.20.1.123Columnfa16e1et100E1Ch1LoopBackLocalread-writecurrent16E1-ET100(T/S) Series card port E1 channel 1 loop back: 0:Off 2:RLB (Max used 15 channels)
1.3.6.1.4.1.4756.20.360.20.1.124Columnfa16e1et100E1Ch2LoopBackLocalread-writecurrent16E1-ET100(T/S) Series card port E1 channel 2 loop back: 0:Off 2:RLB (Max used 15 channels)
1.3.6.1.4.1.4756.20.360.20.1.125Columnfa16e1et100E1Ch3LoopBackLocalread-writecurrent16E1-ET100(T/S) Series card port E1 channel 3 loop back: 0:Off 2:RLB (Max used 15 channels)
1.3.6.1.4.1.4756.20.360.20.1.126Columnfa16e1et100E1Ch4LoopBackLocalread-writecurrent16E1-ET100(T/S) Series card port E1 channel 4 loop back: 0:Off 2:RLB (Max used 15 channels)
1.3.6.1.4.1.4756.20.360.20.1.127Columnfa16e1et100E1Ch5LoopBackLocalread-writecurrent16E1-ET100(T/S) Series card port E1 channel 5 loop back: 0:Off 2:RLB (Max used 15 channels)
1.3.6.1.4.1.4756.20.360.20.1.128Columnfa16e1et100E1Ch6LoopBackLocalread-writecurrent16E1-ET100(T/S) Series card port E1 channel 6 loop back: 0:Off 2:RLB (Max used 15 channels)
1.3.6.1.4.1.4756.20.360.20.1.129Columnfa16e1et100E1Ch7LoopBackLocalread-writecurrent16E1-ET100(T/S) Series card port E1 channel 7 loop back: 0:Off 2:RLB (Max used 15 channels)
1.3.6.1.4.1.4756.20.360.20.1.130Columnfa16e1et100E1Ch8LoopBackLocalread-writecurrent16E1-ET100(T/S) Series card port E1 channel 8 loop back: 0:Off 2:RLB (Max used 15 channels)
1.3.6.1.4.1.4756.20.360.20.1.131Columnfa16e1et100E1Ch9LoopBackLocalread-writecurrent16E1-ET100(T/S) Series card port E1 channel 9 loop back: 0:Off 2:RLB (Max used 15 channels)
1.3.6.1.4.1.4756.20.360.20.1.132Columnfa16e1et100E1Ch10LoopBackLocalread-writecurrent16E1-ET100(T/S) Series card port E1 channel 10 loop back: 0:Off 2:RLB (Max used 15 channels)
1.3.6.1.4.1.4756.20.360.20.1.133Columnfa16e1et100E1Ch11LoopBackLocalread-writecurrent16E1-ET100(T/S) Series card port E1 channel 11 loop back: 0:Off 2:RLB (Max used 15 channels)
1.3.6.1.4.1.4756.20.360.20.1.134Columnfa16e1et100E1Ch12LoopBackLocalread-writecurrent16E1-ET100(T/S) Series card port E1 channel 12 loop back: 0:Off 2:RLB (Max used 15 channels)
1.3.6.1.4.1.4756.20.360.20.1.135Columnfa16e1et100E1Ch13LoopBackLocalread-writecurrent16E1-ET100(T/S) Series card port E1 channel 13 loop back: 0:Off 2:RLB (Max used 15 channels)
1.3.6.1.4.1.4756.20.360.20.1.136Columnfa16e1et100E1Ch14LoopBackLocalread-writecurrent16E1-ET100(T/S) Series card port E1 channel 14 loop back: 0:Off 2:RLB (Max used 15 channels)
1.3.6.1.4.1.4756.20.360.20.1.137Columnfa16e1et100E1Ch15LoopBackLocalread-writecurrent16E1-ET100(T/S) Series card port E1 channel 15 loop back: 0:Off 2:RLB (Max used 15 channels)
1.3.6.1.4.1.4756.20.360.20.1.138Columnfa16e1et100E1Ch16LoopBackLocalread-writecurrent16E1-ET100(T/S) Series card port E1 channel 16 loop back: 0:Off 2:RLB (Max used 15 channels)
1.3.6.1.4.1.4756.20.360.20.1.139Columnfa16e1et100FxLinkLocalread-onlycurrent16E1-ET100S Series card Fiber siganl detect status: 0:Down or Fiber unplugged 1:Up or Singal detected
1.3.6.1.4.1.4756.20.360.20.1.140Columnfa16e1et100FxLaserLocalread-onlycurrent16E1-ET100S Series card laser status: 0:Normal 1:Error
1.3.6.1.4.1.4756.20.360.20.1.141Columnfa16e1et100FxActiveLocalread-writecurrent16E1-ET100S Series card Fiber active: 0:Inactive 1:Active
1.3.6.1.4.1.4756.20.360.20.1.142Columnfa16e1et100FxLaserOutputLocalread-writecurrent16E1-ET100S Series card laser output: 0:disable 1:Enable
1.3.6.1.4.1.4756.20.360.20.1.143Columnfa16e1et100FxOpModeLocalread-writecurrent16E1-ET100S Series card operation mode: 0:Switch 1:Convert
1.3.6.1.4.1.4756.20.360.20.1.144Columnfa16e1et100UtpLinkLocalread-onlycurrent16E1-ET100T Series card UTP link status: 0:Link Down 1:Link Up
1.3.6.1.4.1.4756.20.360.20.1.145Columnfa16e1et100UtpStatusLocalread-onlycurrent16E1-ET100T Series card UTP link mode status: 0:None, Maybe link down 1:Link at 10Mbps, Half duplex 2:Link at 10Mbps, Full duplex 3:Link at 100Mbps, Half duple…
1.3.6.1.4.1.4756.20.360.20.1.146Columnfa16e1et100UtpFlowCtrlStsLocalread-onlycurrent16E1-ET100T Series card UTP flow control status: 0:Disable 1:Enable
1.3.6.1.4.1.4756.20.360.20.1.147Columnfa16e1et100UtpModeLocalread-writecurrent16E1-ET100T Series card UTP mode: 0:Disable 1:Enable and autoNegotiation 3:Enable and force to 10Mbps, Half duplex 4:Enable and force to 10Mbps, Full duplex 5:…
1.3.6.1.4.1.4756.20.360.20.1.148Columnfa16e1et100UtpFlowCtrlLocalread-writecurrent16E1-ET100T Series card UTP flow control: 0:Disable 1:Enable
1.3.6.1.4.1.4756.20.360.20.1.149Columnfa16e1et100SpeedLimitLocalread-writecurrent16E1-ET100(T/S) Series card speed limit: Limited = this value * 32Kbps, this value is restricted to 0 ~ 3125, 0 to disable
1.3.6.1.4.1.4756.20.360.20.1.150Columnfa16e1et100VlanAwareLocalread-writecurrent16E1-ET100(T/S) Series card 802.1q VLAN tag aware: 0:Disable 1:Enable
1.3.6.1.4.1.4756.20.360.20.1.151Columnfa16e1et100VlanIDLocalread-writecurrent16E1-ET100(T/S) Series card VLAN ID: The ID is restricted to 1 ~ 4094
1.3.6.1.4.1.4756.20.360.20.1.152Columnfa16e1et100RemoteDeviceLocalread-onlycurrentFRM220A-16E1 Series card remote device status: 0:Link Down 1:Link Up
1.3.6.1.4.1.4756.20.360.20.1.153Columnfa16e1et100RemotePowerLocalread-onlycurrent16E1-ET100(T/S) Series card remote device power status: 0:Normal 1:Power off
1.3.6.1.4.1.4756.20.360.20.1.154Columnfa16e1et100TimingSourceLocalread-writecurrent16E1-ET100(T/S) Series card clock: 0:Internal oscillatro 1:Recovery from E1 channel 1 2:Recovery from E1 channel 2 3:Recovery from E1 channel 3 4:Recovery from…
1.3.6.1.4.1.4756.20.360.20.1.155Columnfa16e1et100FCSofGFPLocalread-writecurrent16E1-ET100(T/S) Series card FCS of GFP: 0:Disable 1:Enable
1.3.6.1.4.1.4756.20.360.20.1.156Columnfa16e1et100AutoChAdjustLocalread-writecurrent16E1-ET100(T/S) Series card auto channel Bdjust: 0:Disable 1:Enable
1.3.6.1.4.1.4756.20.360.20.1.157Columnfa16e1et100PayloadScrambleLocalread-writecurrent16E1-ET100(T/S) Series card payload scramble: 0:Disable 1:Enable
1.3.6.1.4.1.4756.20.360.20.1.158Columnfa16e1et100FailoverLocalread-writecurrent16E1-ET100(T/S) Series card failover: 0:Disable 1:Enable
1.3.6.1.4.1.4756.20.360.20.1.159Columnfa16e1et100LOMLocalread-onlycurrent16E1-ET100(T/S) Series card LOM status: 0:No 1:Yes
1.3.6.1.4.1.4756.20.360.20.1.160Columnfa16e1et100SQMLocalread-onlycurrent16E1-ET100(T/S) Series card SQM status: 0:No 1:Yes
1.3.6.1.4.1.4756.20.360.20.1.161Columnfa16e1et100CRCLocalread-onlycurrent16E1-ET100(T/S) Series card CRC status: 0:No 1:Yes
1.3.6.1.4.1.4756.20.360.20.1.162Columnfa16e1et100LOALocalread-onlycurrent16E1-ET100(T/S) Series card LOA status: 0:No 1:Yes
1.3.6.1.4.1.4756.20.360.20.1.163Columnfa16e1et100LFDLocalread-onlycurrent16E1-ET100(T/S) Series card LFD status: 0:No 1:Yes
1.3.6.1.4.1.4756.20.360.20.1.164Columnfa16e1et100DDTOLocalread-onlycurrent16E1-ET100(T/S) Series card DDTO status: 0:No 1:Yes
1.3.6.1.4.1.4756.20.360.20.1.165Columnfa16e1et100VcatMember1Localread-writecurrent16E1-ET100(T/S) Series card VACT member 1: 0:Disable 1:Enable
1.3.6.1.4.1.4756.20.360.20.1.166Columnfa16e1et100VcatMember2Localread-writecurrent16E1-ET100(T/S) Series card VACT member 2: 0:Disable 1:Enable
1.3.6.1.4.1.4756.20.360.20.1.167Columnfa16e1et100VcatMember3Localread-writecurrent16E1-ET100(T/S) Series card VACT member 3: 0:Disable 1:Enable
1.3.6.1.4.1.4756.20.360.20.1.168Columnfa16e1et100VcatMember4Localread-writecurrent16E1-ET100(T/S) Series card VACT member 4: 0:Disable 1:Enable
1.3.6.1.4.1.4756.20.360.20.1.169Columnfa16e1et100VcatMember5Localread-writecurrent16E1-ET100(T/S) Series card VACT member 5: 0:Disable 1:Enable
1.3.6.1.4.1.4756.20.360.20.1.170Columnfa16e1et100VcatMember6Localread-writecurrent16E1-ET100(T/S) Series card VACT member 6: 0:Disable 1:Enable
1.3.6.1.4.1.4756.20.360.20.1.171Columnfa16e1et100VcatMember7Localread-writecurrent16E1-ET100(T/S) Series card VACT member 7: 0:Disable 1:Enable
1.3.6.1.4.1.4756.20.360.20.1.172Columnfa16e1et100VcatMember8Localread-writecurrent16E1-ET100(T/S) Series card VACT member 8: 0:Disable 1:Enable
1.3.6.1.4.1.4756.20.360.20.1.173Columnfa16e1et100VcatMember9Localread-writecurrent16E1-ET100(T/S) Series card VACT member 9: 0:Disable 1:Enable
1.3.6.1.4.1.4756.20.360.20.1.174Columnfa16e1et100VcatMember10Localread-writecurrent16E1-ET100(T/S) Series card VACT member 10: 0:Disable 1:Enable
1.3.6.1.4.1.4756.20.360.20.1.175Columnfa16e1et100VcatMember11Localread-writecurrent16E1-ET100(T/S) Series card VACT member 11: 0:Disable 1:Enable
1.3.6.1.4.1.4756.20.360.20.1.176Columnfa16e1et100VcatMember12Localread-writecurrent16E1-ET100(T/S) Series card VACT member 12: 0:Disable 1:Enable
1.3.6.1.4.1.4756.20.360.20.1.177Columnfa16e1et100VcatMember13Localread-writecurrent16E1-ET100(T/S) Series card VACT member 13: 0:Disable 1:Enable
1.3.6.1.4.1.4756.20.360.20.1.178Columnfa16e1et100VcatMember14Localread-writecurrent16E1-ET100(T/S) Series card VACT member 14: 0:Disable 1:Enable
1.3.6.1.4.1.4756.20.360.20.1.179Columnfa16e1et100VcatMember15Localread-writecurrent16E1-ET100(T/S) Series card VACT member 15: 0:Disable 1:Enable
1.3.6.1.4.1.4756.20.360.20.1.180Columnfa16e1et100VcatMember16Localread-writecurrent16E1-ET100(T/S) Series card VACT member 16: 0:Disable 1:Enable
1.3.6.1.4.1.4756.20.360.20.1.181Columnfa16e1et100SnmpChannel1Localread-writecurrent16E1-ET100(T/S) Series card SNMP channel 0: 0:No use 1:Use
1.3.6.1.4.1.4756.20.360.20.1.182Columnfa16e1et100SnmpChannel2Localread-writecurrent16E1-ET100(T/S) Series card SNMP channel 1: 0:No use 1:Use
1.3.6.1.4.1.4756.20.360.20.1.183Columnfa16e1et100SnmpChannel3Localread-writecurrent16E1-ET100(T/S) Series card SNMP channel 3: 0:No use 1:Use
1.3.6.1.4.1.4756.20.360.20.1.184Columnfa16e1et100SnmpChannel4Localread-writecurrent16E1-ET100(T/S) Series card SNMP channel 4: 0:No use 1:Use
1.3.6.1.4.1.4756.20.360.20.1.185Columnfa16e1et100ErrSecLocalread-onlycurrent16E1-ET100(T/S) Series card, errored seconds of BERT result.
1.3.6.1.4.1.4756.20.360.20.1.186Columnfa16e1et100ErrFreeSecLocalread-onlycurrent16E1-ET100(T/S) Series card, errored free seconds of BERT result.
1.3.6.1.4.1.4756.20.360.20.1.187Columnfa16e1et100ServErrSecLocalread-onlycurrent16E1-ET100(T/S) Series card, severely errored seconds of BERT result.
1.3.6.1.4.1.4756.20.360.20.1.188Columnfa16e1et100BertFunctionLocalread-writecurrent16E1-ET100(T/S) Series card bert function: 0:Disable 1:Enable
1.3.6.1.4.1.4756.20.360.20.1.189Columnfa16e1et100ClrBertDataLocalread-writecurrent16E1-ET100(T/S) Series card bert data clear: 0:Normal 1:Clear
1.3.6.1.4.1.4756.20.360.20.1.190Columnfa16e1et100BertE1ChannelLocalread-writecurrent16E1-ET100(T/S) Series card bert E1 channel number: 0:E1 channel 1 1:E1 channel 2 2:E1 channel 3 3:E1 channel 4 4:E1 channel 5 5:E1 channel 6 6:E1 channel 7 7:…
1.3.6.1.4.1.4756.20.360.20.1.191Columnfa16e1et100RmonFunctionLocalread-writecurrent16E1-ET100(T/S) Series RMON function : 0:Disable 1:Enable
1.3.6.1.4.1.4756.20.360.20.1.192Columnfa16e1et100RmonTxLocalread-onlycurrent16E1-ET100(T/S) Series card RMON Tx counter.
1.3.6.1.4.1.4756.20.360.20.1.193Columnfa16e1et100RmonRxLocalread-onlycurrent16E1-ET100(T/S) Series card RMON Rx counter.
1.3.6.1.4.1.4756.20.360.20.1.194Columnfa16e1et100ClrRmonTxLocalread-writecurrent16E1-ET100(T/S) Series card clear RMON Tx counter: 0:Normal 1:Clear
1.3.6.1.4.1.4756.20.360.20.1.195Columnfa16e1et100ClrRmonRxLocalread-writecurrent16E1-ET100(T/S) Series card clear RMON Rx counter: 0:Normal 1:Clear
1.3.6.1.4.1.4756.20.360.20.1.196Columnfa16e1et100SfpLocalread-onlycurrent16E1-ET100(T/S) Series card, SFP existed: 0:No 1:Yes
1.3.6.1.4.1.4756.20.360.20.1.197Columnfa16e1et100SfpVendorLocalread-onlycurrent16E1-ET100(T/S) Series card, Vendor name of SFP.
1.3.6.1.4.1.4756.20.360.20.1.198Columnfa16e1et100SfpPartNoLocalread-onlycurrent16E1-ET100(T/S) Series card, Vendor part number of SFP.
1.3.6.1.4.1.4756.20.360.20.1.199Columnfa16e1et100SfpFiberTypeLocalread-onlycurrent16E1-ET100(T/S) Series card, Fiber Type of SFP.
1.3.6.1.4.1.4756.20.360.20.1.200Columnfa16e1et100SfpTxWaveLenLocalread-onlycurrent16E1-ET100(T/S) Series card, Tx Wave length of SFP.
1.3.6.1.4.1.4756.20.360.20.1.201Columnfa16e1et100SfpRxWaveLenLocalread-onlycurrent16E1-ET100(T/S) Series card, Rx Wave length of SFP.
1.3.6.1.4.1.4756.20.360.20.1.202Columnfa16e1et100SfpLinkLenLocalread-onlycurrent16E1-ET100(T/S) Series card, Link length of SFP.
1.3.6.1.4.1.4756.20.360.20.1.203Columnfa16e1et100SfpModelIDLocalread-onlycurrent16E1-ET100(T/S) Series card, model ID of SFP.
1.3.6.1.4.1.4756.20.360.20.1.204Columnfa16e1et100SfpVersionLocalread-onlycurrent16E1-ET100(T/S) Series card, the version of SFP.
1.3.6.1.4.1.4756.20.360.20.1.205Columnfa16e1et100SfpModelTypeLocalread-onlycurrent16E1-ET100(T/S) Series card, model type of SFP.
1.3.6.1.4.1.4756.20.360.20.1.206Columnfa16e1et100DDInformationLocalread-onlycurrent16E1-ET100(T/S) Series card, D/D information of SFP Supported: 0:No, 1:Yes
1.3.6.1.4.1.4756.20.360.20.1.207Columnfa16e1et100DDRxSensLocalread-onlycurrent16E1-ET100(T/S) Series card, Sensitivity of D/D information.
1.3.6.1.4.1.4756.20.360.20.1.208Columnfa16e1et100DDTxPowerLocalread-onlycurrent16E1-ET100(T/S) Series card, Tx power of D/D information.
1.3.6.1.4.1.4756.20.360.20.1.209Columnfa16e1et100DDRxPowerLocalread-onlycurrent16E1-ET100(T/S) Series card, Rx power of D/D information.
1.3.6.1.4.1.4756.20.360.20.1.210Columnfa16e1et100DDTempLocalread-onlycurrent16E1-ET100(T/S) Series card, Temperature of D/D information in degree C.
1.3.6.1.4.1.4756.20.360.20.1.211Columnfa16e1et100DDBiasLocalread-onlycurrent16E1-ET100(T/S) Series card, BIAS of D/D information.
1.3.6.1.4.1.4756.20.360.20.1.212Columnfa16e1et100DDVoltageLocalread-onlycurrent16E1-ET100(T/S) Series card, Voltage of D/D information.
1.3.6.1.4.1.4756.20.360.20.1.213Columnfa16e1et100ChannelDefectLocalread-writecurrent16E1-ET100(T/S) Series card Channel Defect: 0:Disable 4:1E-4 6:1E-6
1.3.6.1.4.1.4756.20.360.20.1.214Columnfa16e1et100LoopDetectionLocalread-writecurrent16E1-ET100(T/S) Series card Loop Detection: 0:Disable 1:Enable
1.3.6.1.4.1.4756.20.360.20.1.215Columnfa16e1et100LoopCh1Localread-onlycurrent16E1-ET100(T/S) Series card E1 channel 1 Loop Check State: 0:No 1:Yes
1.3.6.1.4.1.4756.20.360.20.1.216Columnfa16e1et100LoopCh2Localread-onlycurrent16E1-ET100(T/S) Series card E1 channel 2 Loop Check State: 0:No 1:Yes
1.3.6.1.4.1.4756.20.360.20.1.217Columnfa16e1et100LoopCh3Localread-onlycurrent16E1-ET100(T/S) Series card E1 channel 3 Loop Check State: 0:No 1:Yes
1.3.6.1.4.1.4756.20.360.20.1.218Columnfa16e1et100LoopCh4Localread-onlycurrent16E1-ET100(T/S) Series card E1 channel 4 Loop Check State: 0:No 1:Yes
1.3.6.1.4.1.4756.20.360.20.1.219Columnfa16e1et100LoopCh5Localread-onlycurrent16E1-ET100(T/S) Series card E1 channel 5 Loop Check State: 0:No 1:Yes
1.3.6.1.4.1.4756.20.360.20.1.220Columnfa16e1et100LoopCh6Localread-onlycurrent16E1-ET100(T/S) Series card E1 channel 6 Loop Check State: 0:No 1:Yes
1.3.6.1.4.1.4756.20.360.20.1.221Columnfa16e1et100LoopCh7Localread-onlycurrent16E1-ET100(T/S) Series card E1 channel 7 Loop Check State: 0:No 1:Yes
1.3.6.1.4.1.4756.20.360.20.1.222Columnfa16e1et100LoopCh8Localread-onlycurrent16E1-ET100(T/S) Series card E1 channel 8 Loop Check State: 0:No 1:Yes
1.3.6.1.4.1.4756.20.360.20.1.223Columnfa16e1et100LoopCh9Localread-onlycurrent16E1-ET100(T/S) Series card E1 channel 9 Loop Check State: 0:No 1:Yes
1.3.6.1.4.1.4756.20.360.20.1.224Columnfa16e1et100LoopCh10Localread-onlycurrent16E1-ET100(T/S) Series card E1 channel 10 Loop Check State: 0:No 1:Yes
1.3.6.1.4.1.4756.20.360.20.1.225Columnfa16e1et100LoopCh11Localread-onlycurrent16E1-ET100(T/S) Series card E1 channel 11 Loop Check State: 0:No 1:Yes
1.3.6.1.4.1.4756.20.360.20.1.226Columnfa16e1et100LoopCh12Localread-onlycurrent16E1-ET100(T/S) Series card E1 channel 12 Loop Check State: 0:No 1:Yes
1.3.6.1.4.1.4756.20.360.20.1.227Columnfa16e1et100LoopCh13Localread-onlycurrent16E1-ET100(T/S) Series card E1 channel 13 Loop Check State: 0:No 1:Yes
1.3.6.1.4.1.4756.20.360.20.1.228Columnfa16e1et100LoopCh14Localread-onlycurrent16E1-ET100(T/S) Series card E1 channel 14 Loop Check State: 0:No 1:Yes
1.3.6.1.4.1.4756.20.360.20.1.229Columnfa16e1et100LoopCh15Localread-onlycurrent16E1-ET100(T/S) Series card E1 channel 15 Loop Check State: 0:No 1:Yes
1.3.6.1.4.1.4756.20.360.20.1.230Columnfa16e1et100LoopCh16Localread-onlycurrent16E1-ET100(T/S) Series card E1 channel 16 Loop Check State: 0:No 1:Yes
1.3.6.1.4.1.4756.20.360.20.1.231Columnfa16e1et100DefectCh1Localread-onlycurrent16E1-ET100(T/S) Series card E1 channel 1 Defect Status: 0:No 1:Yes
1.3.6.1.4.1.4756.20.360.20.1.232Columnfa16e1et100DefectCh2Localread-onlycurrent16E1-ET100(T/S) Series card E1 channel 2 Defect Status: 0:No 1:Yes
1.3.6.1.4.1.4756.20.360.20.1.233Columnfa16e1et100DefectCh3Localread-onlycurrent16E1-ET100(T/S) Series card E1 channel 3 Defect Status: 0:No 1:Yes
1.3.6.1.4.1.4756.20.360.20.1.234Columnfa16e1et100DefectCh4Localread-onlycurrent16E1-ET100(T/S) Series card E1 channel 4 Defect Status: 0:No 1:Yes
1.3.6.1.4.1.4756.20.360.20.1.235Columnfa16e1et100DefectCh5Localread-onlycurrent16E1-ET100(T/S) Series card E1 channel 5 Defect Status: 0:No 1:Yes
1.3.6.1.4.1.4756.20.360.20.1.236Columnfa16e1et100DefectCh6Localread-onlycurrent16E1-ET100(T/S) Series card E1 channel 6 Defect Status: 0:No 1:Yes
1.3.6.1.4.1.4756.20.360.20.1.237Columnfa16e1et100DefectCh7Localread-onlycurrent16E1-ET100(T/S) Series card E1 channel 7 Defect Status: 0:No 1:Yes
1.3.6.1.4.1.4756.20.360.20.1.238Columnfa16e1et100DefectCh8Localread-onlycurrent16E1-ET100(T/S) Series card E1 channel 8 Defect Status: 0:No 1:Yes
1.3.6.1.4.1.4756.20.360.20.1.239Columnfa16e1et100DefectCh9Localread-onlycurrent16E1-ET100(T/S) Series card E1 channel 9 Defect Status: 0:No 1:Yes
1.3.6.1.4.1.4756.20.360.20.1.240Columnfa16e1et100DefectCh10Localread-onlycurrent16E1-ET100(T/S) Series card E1 channel 10 Defect Status: 0:No 1:Yes
1.3.6.1.4.1.4756.20.360.20.1.241Columnfa16e1et100DefectCh11Localread-onlycurrent16E1-ET100(T/S) Series card E1 channel 11 Defect Status: 0:No 1:Yes
1.3.6.1.4.1.4756.20.360.20.1.242Columnfa16e1et100DefectCh12Localread-onlycurrent16E1-ET100(T/S) Series card E1 channel 12 Defect Status: 0:No 1:Yes
1.3.6.1.4.1.4756.20.360.20.1.243Columnfa16e1et100DefectCh13Localread-onlycurrent16E1-ET100(T/S) Series card E1 channel 13 Defect Status: 0:No 1:Yes
1.3.6.1.4.1.4756.20.360.20.1.244Columnfa16e1et100DefectCh14Localread-onlycurrent16E1-ET100(T/S) Series card E1 channel 14 Defect Status: 0:No 1:Yes
1.3.6.1.4.1.4756.20.360.20.1.245Columnfa16e1et100DefectCh15Localread-onlycurrent16E1-ET100(T/S) Series card E1 channel 15 Defect Status: 0:No 1:Yes
1.3.6.1.4.1.4756.20.360.20.1.246Columnfa16e1et100DefectCh16Localread-onlycurrent16E1-ET100(T/S) Series card E1 channel 16 Defect Status: 0:No 1:Yes
1.3.6.1.4.1.4756.20.360.20.1.247Columnfa16e1et100FxSignalLocalread-onlycurrent16E1-ET100(T/S) Series card Fiber signal detect(SD): 0:Fiber unplugged 1:Signal detected
1.3.6.1.4.1.4756.20.360.20.1.248Columnfa16e1et100PortResetLocalread-writecurrent16E1-ET100(T/S) Series card Port Reset: 0:Action 1:Off
1.3.6.1.4.1.4756.20.360.20.1.249Columnfa16e1et100VLANModeLocalread-writecurrent16E1-ET100(T/S) Series card VLAN mode: 0:MODE2 1:MODE1
1.3.6.1.4.1.4756.20.360.20.1.250Columnfa16e1et100ETagSelectEntryLocalread-writecurrent16E1-ET100(T/S) Series card ETag select entry:
1.3.6.1.4.1.4756.20.360.20.1.251Columnfa16e1et100ETagMethodLocalread-writecurrent16E1-ET100(T/S) Series card ETag Method: 0: Intouch 1: Add Tag 2: Remove Tag
1.3.6.1.4.1.4756.20.360.20.1.252Columnfa16e1et100VLANTableVID1Localread-writecurrent16E1-ET100(T/S) Series card VLAN Table: VLAN ID1
1.3.6.1.4.1.4756.20.360.20.1.253Columnfa16e1et100VLANTableVID2Localread-writecurrent16E1-ET100(T/S) Series card VLAN Table: VLAN ID2
1.3.6.1.4.1.4756.20.360.20.1.254Columnfa16e1et100VLANTableVID3Localread-writecurrent16E1-ET100(T/S) Series card VLAN Table: VLAN ID3
1.3.6.1.4.1.4756.20.360.20.1.255Columnfa16e1et100VLANTableVID4Localread-writecurrent16E1-ET100(T/S) Series card VLAN Table: VLAN ID4
1.3.6.1.4.1.4756.20.360.20.1.256Columnfa16e1et100VLANTableVID5Localread-writecurrent16E1-ET100(T/S) Series card VLAN Table: VLAN ID5
1.3.6.1.4.1.4756.20.360.20.1.257Columnfa16e1et100VLANTableVID6Localread-writecurrent16E1-ET100(T/S) Series card VLAN Table: VLAN ID6
1.3.6.1.4.1.4756.20.360.20.1.258Columnfa16e1et100VLANTableVID7Localread-writecurrent16E1-ET100(T/S) Series card VLAN Table: VLAN ID7
1.3.6.1.4.1.4756.20.360.20.1.259Columnfa16e1et100VLANTableVID8Localread-writecurrent16E1-ET100(T/S) Series card VLAN Table: VLAN ID8
1.3.6.1.4.1.4756.20.360.20.1.260Columnfa16e1et100VLANTableVID9Localread-writecurrent16E1-ET100(T/S) Series card VLAN Table: VLAN ID9
1.3.6.1.4.1.4756.20.360.20.1.261Columnfa16e1et100VLANTableVID10Localread-writecurrent16E1-ET100(T/S) Series card VLAN Table: VLAN ID10
1.3.6.1.4.1.4756.20.360.20.1.262Columnfa16e1et100VLANTableVID11Localread-writecurrent16E1-ET100(T/S) Series card VLAN Table: VLAN ID11
1.3.6.1.4.1.4756.20.360.20.1.263Columnfa16e1et100VLANTableVID12Localread-writecurrent16E1-ET100(T/S) Series card VLAN Table: VLAN ID12
1.3.6.1.4.1.4756.20.360.20.1.264Columnfa16e1et100VLANTableVID13Localread-writecurrent16E1-ET100(T/S) Series card VLAN Table: VLAN ID13
1.3.6.1.4.1.4756.20.360.20.1.265Columnfa16e1et100VLANTableVID14Localread-writecurrent16E1-ET100(T/S) Series card VLAN Table: VLAN ID14
1.3.6.1.4.1.4756.20.360.20.1.266Columnfa16e1et100VLANTableVID15Localread-writecurrent16E1-ET100(T/S) Series card VLAN Table: VLAN ID15
1.3.6.1.4.1.4756.20.360.20.1.267Columnfa16e1et100VLANTableVID16Localread-writecurrent16E1-ET100(T/S) Series card VLAN Table: VLAN ID16
1.3.6.1.4.1.4756.20.361Nodef16E1RemoteCards
1.3.6.1.4.1.4756.20.361.20Tablef16E1RemoteTablenot-accessiblecurrentA list of local FRM220-16E1-ET100 series card entries. The number of entries is f16E1-No-L.
1.3.6.1.4.1.4756.20.361.20.1Rowf16E1RemoteEntrynot-accessiblecurrentAn entry containing management information applicable to a particular local FRM220-16E1 series card.
1.3.6.1.4.1.4756.20.361.20.1.1Columnfa16e1et100ChassisIndexRemoteread-onlycurrentA unique value for each card. It starts from 0 to 9 contiguously.
1.3.6.1.4.1.4756.20.361.20.1.2Columnfa16e1et100SlotIndexRemoteread-onlycurrentA unique value for each card. It starts from 1 to 20 contiguously.
1.3.6.1.4.1.4756.20.361.20.1.3Columnfa16e1et100CardHWVerRemoteread-onlycurrent16E1-ET100(T/S) Series card hardware version x.xxx
1.3.6.1.4.1.4756.20.361.20.1.4Columnfa16e1et100CardFWVerRemoteread-onlycurrent16E1-ET100(T/S) Series card firmware version x.xxx
1.3.6.1.4.1.4756.20.361.20.1.5Columnfa16e1et100CardCPLDVerRemoteread-onlycurrent16E1-ET100(T/S) Series card CPLD version x.xxx
1.3.6.1.4.1.4756.20.361.20.1.6Columnfa16e1et100CardFPGAVerRemoteread-onlycurrent16E1-ET100(T/S) Series card FPGA version x.xxx
1.3.6.1.4.1.4756.20.361.20.1.7Columnfa16e1et100ModelRemoteread-onlycurrentCard Type: 0:16E1-ET100T 1:16E1-ET100S
1.3.6.1.4.1.4756.20.361.20.1.8Columnfa16e1et100SystemStatusRemoteread-onlycurrent16E1-ET100(T/S) Series card system status: 0:Normal 1:Alarm
1.3.6.1.4.1.4756.20.361.20.1.9Columnfa16e1et100DeviceActiveRemoteread-onlycurrent16E1-ET100(T/S) Series card active: 0:Disable 1:Enable
1.3.6.1.4.1.4756.20.361.20.1.10Columnfa16e1et100SetToDefaultRemoteread-writecurrent16E1-ET100(T/S) Series card port set to default: 0:Off 1:Trigger
1.3.6.1.4.1.4756.20.361.20.1.11Columnfa16e1et100E1Ch1SingalRemoteread-onlycurrent16E1-ET100(T/S) Series card E1 channel 1 signal status: 0:Singal Loss 1:Normal
1.3.6.1.4.1.4756.20.361.20.1.12Columnfa16e1et100E1Ch2SingalRemoteread-onlycurrent16E1-ET100(T/S) Series card E1 channel 2 signal status: 0:Singal Loss 1:Normal
1.3.6.1.4.1.4756.20.361.20.1.13Columnfa16e1et100E1Ch3SingalRemoteread-onlycurrent16E1-ET100(T/S) Series card E1 channel 3 signal status: 0:Singal Loss 1:Normal
1.3.6.1.4.1.4756.20.361.20.1.14Columnfa16e1et100E1Ch4SingalRemoteread-onlycurrent16E1-ET100(T/S) Series card E1 channel 4 signal status: 0:Singal Loss 1:Normal
1.3.6.1.4.1.4756.20.361.20.1.15Columnfa16e1et100E1Ch5SingalRemoteread-onlycurrent16E1-ET100(T/S) Series card E1 channel 5 signal status: 0:Singal Loss 1:Normal
1.3.6.1.4.1.4756.20.361.20.1.16Columnfa16e1et100E1Ch6SingalRemoteread-onlycurrent16E1-ET100(T/S) Series card E1 channel 6 signal status: 0:Singal Loss 1:Normal
1.3.6.1.4.1.4756.20.361.20.1.17Columnfa16e1et100E1Ch7SingalRemoteread-onlycurrent16E1-ET100(T/S) Series card E1 channel 7 signal status: 0:Singal Loss 1:Normal
1.3.6.1.4.1.4756.20.361.20.1.18Columnfa16e1et100E1Ch8SingalRemoteread-onlycurrent16E1-ET100(T/S) Series card E1 channel 8 signal status: 0:Singal Loss 1:Normal
1.3.6.1.4.1.4756.20.361.20.1.19Columnfa16e1et100E1Ch9SingalRemoteread-onlycurrent16E1-ET100(T/S) Series card E1 channel 9 signal status: 0:Singal Loss 1:Normal
1.3.6.1.4.1.4756.20.361.20.1.20Columnfa16e1et100E1Ch10SingalRemoteread-onlycurrent16E1-ET100(T/S) Series card E1 channel 10 signal status: 0:Singal Loss 1:Normal
1.3.6.1.4.1.4756.20.361.20.1.21Columnfa16e1et100E1Ch11SingalRemoteread-onlycurrent16E1-ET100(T/S) Series card E1 channel 11 signal status: 0:Singal Loss 1:Normal
1.3.6.1.4.1.4756.20.361.20.1.22Columnfa16e1et100E1Ch12SingalRemoteread-onlycurrent16E1-ET100(T/S) Series card E1 channel 12 signal status: 0:Singal Loss 1:Normal
1.3.6.1.4.1.4756.20.361.20.1.23Columnfa16e1et100E1Ch13SingalRemoteread-onlycurrent16E1-ET100(T/S) Series card E1 channel 13 signal status: 0:Singal Loss 1:Normal
1.3.6.1.4.1.4756.20.361.20.1.24Columnfa16e1et100E1Ch14SingalRemoteread-onlycurrent16E1-ET100(T/S) Series card E1 channel 14 signal status: 0:Singal Loss 1:Normal
1.3.6.1.4.1.4756.20.361.20.1.25Columnfa16e1et100E1Ch15SingalRemoteread-onlycurrent16E1-ET100(T/S) Series card E1 channel 15 signal status: 0:Singal Loss 1:Normal
1.3.6.1.4.1.4756.20.361.20.1.26Columnfa16e1et100E1Ch16SingalRemoteread-onlycurrent16E1-ET100(T/S) Series card E1 channel 16 signal status: 0:Singal Loss 1:Normal
1.3.6.1.4.1.4756.20.361.20.1.27Columnfa16e1et100E1Ch1SyncRemoteread-onlycurrent16E1-ET100(T/S) Series card E1 channel 1 sync status: 0:Sync Loss 1:Sync
1.3.6.1.4.1.4756.20.361.20.1.28Columnfa16e1et100E1Ch2SyncRemoteread-onlycurrent16E1-ET100(T/S) Series card E1 channel 2 sync status: 0:Sync Loss 1:Sync
1.3.6.1.4.1.4756.20.361.20.1.29Columnfa16e1et100E1Ch3SyncRemoteread-onlycurrent16E1-ET100(T/S) Series card E1 channel 3 sync status: 0:Sync Loss 1:Sync
1.3.6.1.4.1.4756.20.361.20.1.30Columnfa16e1et100E1Ch4SyncRemoteread-onlycurrent16E1-ET100(T/S) Series card E1 channel 4 sync status: 0:Sync Loss 1:Sync
1.3.6.1.4.1.4756.20.361.20.1.31Columnfa16e1et100E1Ch5SyncRemoteread-onlycurrent16E1-ET100(T/S) Series card E1 channel 5 sync status: 0:Sync Loss 1:Sync
1.3.6.1.4.1.4756.20.361.20.1.32Columnfa16e1et100E1Ch6SyncRemoteread-onlycurrent16E1-ET100(T/S) Series card E1 channel 6 sync status: 0:Sync Loss 1:Sync
1.3.6.1.4.1.4756.20.361.20.1.33Columnfa16e1et100E1Ch7SyncRemoteread-onlycurrent16E1-ET100(T/S) Series card E1 channel 7 sync status: 0:Sync Loss 1:Sync
1.3.6.1.4.1.4756.20.361.20.1.34Columnfa16e1et100E1Ch8SyncRemoteread-onlycurrent16E1-ET100(T/S) Series card E1 channel 8 sync status: 0:Sync Loss 1:Sync
1.3.6.1.4.1.4756.20.361.20.1.35Columnfa16e1et100E1Ch9SyncRemoteread-onlycurrent16E1-ET100(T/S) Series card E1 channel 9 sync status: 0:Sync Loss 1:Sync
1.3.6.1.4.1.4756.20.361.20.1.36Columnfa16e1et100E1Ch10SyncRemoteread-onlycurrent16E1-ET100(T/S) Series card E1 channel 10 sync status: 0:Sync Loss 1:Sync
1.3.6.1.4.1.4756.20.361.20.1.37Columnfa16e1et100E1Ch11SyncRemoteread-onlycurrent16E1-ET100(T/S) Series card E1 channel 11 sync status: 0:Sync Loss 1:Sync
1.3.6.1.4.1.4756.20.361.20.1.38Columnfa16e1et100E1Ch12SyncRemoteread-onlycurrent16E1-ET100(T/S) Series card E1 channel 12 sync status: 0:Sync Loss 1:Sync
1.3.6.1.4.1.4756.20.361.20.1.39Columnfa16e1et100E1Ch13SyncRemoteread-onlycurrent16E1-ET100(T/S) Series card E1 channel 13 sync status: 0:Sync Loss 1:Sync
1.3.6.1.4.1.4756.20.361.20.1.40Columnfa16e1et100E1Ch14SyncRemoteread-onlycurrent16E1-ET100(T/S) Series card E1 channel 14 sync status: 0:Sync Loss 1:Sync
1.3.6.1.4.1.4756.20.361.20.1.41Columnfa16e1et100E1Ch15SyncRemoteread-onlycurrent16E1-ET100(T/S) Series card E1 channel 15 sync status: 0:Sync Loss 1:Sync
1.3.6.1.4.1.4756.20.361.20.1.42Columnfa16e1et100E1Ch16SyncRemoteread-onlycurrent16E1-ET100(T/S) Series card E1 channel 16 sync status: 0:Sync Loss 1:Sync
1.3.6.1.4.1.4756.20.361.20.1.43Columnfa16e1et100E1Ch1RecvAISRemoteread-onlycurrent16E1-ET100(T/S) Series card E1 channel 1 receive AIS status: 0:No 1:Yes
1.3.6.1.4.1.4756.20.361.20.1.44Columnfa16e1et100E1Ch2RecvAISRemoteread-onlycurrent16E1-ET100(T/S) Series card E1 channel 2 receive AIS status: 0:No 1:Yes
1.3.6.1.4.1.4756.20.361.20.1.45Columnfa16e1et100E1Ch3RecvAISRemoteread-onlycurrent16E1-ET100(T/S) Series card E1 channel 3 receive AIS status: 0:No 1:Yes
1.3.6.1.4.1.4756.20.361.20.1.46Columnfa16e1et100E1Ch4RecvAISRemoteread-onlycurrent16E1-ET100(T/S) Series card E1 channel 4 receive AIS status: 0:No 1:Yes
1.3.6.1.4.1.4756.20.361.20.1.47Columnfa16e1et100E1Ch5RecvAISRemoteread-onlycurrent16E1-ET100(T/S) Series card E1 channel 5 receive AIS status: 0:No 1:Yes
1.3.6.1.4.1.4756.20.361.20.1.48Columnfa16e1et100E1Ch6RecvAISRemoteread-onlycurrent16E1-ET100(T/S) Series card E1 channel 6 receive AIS status: 0:No 1:Yes
1.3.6.1.4.1.4756.20.361.20.1.49Columnfa16e1et100E1Ch7RecvAISRemoteread-onlycurrent16E1-ET100(T/S) Series card E1 channel 7 receive AIS status: 0:No 1:Yes
1.3.6.1.4.1.4756.20.361.20.1.50Columnfa16e1et100E1Ch8RecvAISRemoteread-onlycurrent16E1-ET100(T/S) Series card E1 channel 8 receive AIS status: 0:No 1:Yes
1.3.6.1.4.1.4756.20.361.20.1.51Columnfa16e1et100E1Ch9RecvAISRemoteread-onlycurrent16E1-ET100(T/S) Series card E1 channel 9 receive AIS status: 0:No 1:Yes
1.3.6.1.4.1.4756.20.361.20.1.52Columnfa16e1et100E1Ch10RecvAISRemoteread-onlycurrent16E1-ET100(T/S) Series card E1 channel 10 receive AIS status: 0:No 1:Yes
1.3.6.1.4.1.4756.20.361.20.1.53Columnfa16e1et100E1Ch11RecvAISRemoteread-onlycurrent16E1-ET100(T/S) Series card E1 channel 11 receive AIS status: 0:No 1:Yes
1.3.6.1.4.1.4756.20.361.20.1.54Columnfa16e1et100E1Ch12RecvAISRemoteread-onlycurrent16E1-ET100(T/S) Series card E1 channel 12 receive AIS status: 0:No 1:Yes
1.3.6.1.4.1.4756.20.361.20.1.55Columnfa16e1et100E1Ch13RecvAISRemoteread-onlycurrent16E1-ET100(T/S) Series card E1 channel 13 receive AIS status: 0:No 1:Yes
1.3.6.1.4.1.4756.20.361.20.1.56Columnfa16e1et100E1Ch14RecvAISRemoteread-onlycurrent16E1-ET100(T/S) Series card E1 channel 14 receive AIS status: 0:No 1:Yes
1.3.6.1.4.1.4756.20.361.20.1.57Columnfa16e1et100E1Ch15RecvAISRemoteread-onlycurrent16E1-ET100(T/S) Series card E1 channel 15 receive AIS status: 0:No 1:Yes
1.3.6.1.4.1.4756.20.361.20.1.58Columnfa16e1et100E1Ch16RecvAISRemoteread-onlycurrent16E1-ET100(T/S) Series card E1 channel 16 receive AIS status: 0:No 1:Yes
1.3.6.1.4.1.4756.20.361.20.1.59Columnfa16e1et100E1Ch1ConnTypeRemoteread-onlycurrent16E1-ET100(T/S) Series card E1 channel 1 connector type: 0:RJ-48C 1:BNC
1.3.6.1.4.1.4756.20.361.20.1.60Columnfa16e1et100E1Ch2ConnTypeRemoteread-onlycurrent16E1-ET100(T/S) Series card E1 channel 2 connector type: 0:RJ-48C 1:BNC
1.3.6.1.4.1.4756.20.361.20.1.61Columnfa16e1et100E1Ch3ConnTypeRemoteread-onlycurrent16E1-ET100(T/S) Series card E1 channel 3 connector type: 0:RJ-48C 1:BNC
1.3.6.1.4.1.4756.20.361.20.1.62Columnfa16e1et100E1Ch4ConnTypeRemoteread-onlycurrent16E1-ET100(T/S) Series card E1 channel 4 connector type: 0:RJ-48C 1:BNC
1.3.6.1.4.1.4756.20.361.20.1.63Columnfa16e1et100E1Ch5ConnTypeRemoteread-onlycurrent16E1-ET100(T/S) Series card E1 channel 5 connector type: 0:RJ-48C 1:BNC
1.3.6.1.4.1.4756.20.361.20.1.64Columnfa16e1et100E1Ch6ConnTypeRemoteread-onlycurrent16E1-ET100(T/S) Series card E1 channel 6 connector type: 0:RJ-48C 1:BNC
1.3.6.1.4.1.4756.20.361.20.1.65Columnfa16e1et100E1Ch7ConnTypeRemoteread-onlycurrent16E1-ET100(T/S) Series card E1 channel 7 connector type: 0:RJ-48C 1:BNC
1.3.6.1.4.1.4756.20.361.20.1.66Columnfa16e1et100E1Ch8ConnTypeRemoteread-onlycurrent16E1-ET100(T/S) Series card E1 channel 8 connector type: 0:RJ-48C 1:BNC
1.3.6.1.4.1.4756.20.361.20.1.67Columnfa16e1et100E1Ch9ConnTypeRemoteread-onlycurrent16E1-ET100(T/S) Series card E1 channel 9 connector type: 0:RJ-48C 1:BNC
1.3.6.1.4.1.4756.20.361.20.1.68Columnfa16e1et100E1Ch10ConnTypeRemoteread-onlycurrent16E1-ET100(T/S) Series card E1 channel 10 connector type: 0:RJ-48C 1:BNC
1.3.6.1.4.1.4756.20.361.20.1.69Columnfa16e1et100E1Ch11ConnTypeRemoteread-onlycurrent16E1-ET100(T/S) Series card E1 channel 11 connector type: 0:RJ-48C 1:BNC
1.3.6.1.4.1.4756.20.361.20.1.70Columnfa16e1et100E1Ch12ConnTypeRemoteread-onlycurrent16E1-ET100(T/S) Series card E1 channel 12 connector type: 0:RJ-48C 1:BNC
1.3.6.1.4.1.4756.20.361.20.1.71Columnfa16e1et100E1Ch13ConnTypeRemoteread-onlycurrent16E1-ET100(T/S) Series card E1 channel 13 connector type: 0:RJ-48C 1:BNC
1.3.6.1.4.1.4756.20.361.20.1.72Columnfa16e1et100E1Ch14ConnTypeRemoteread-onlycurrent16E1-ET100(T/S) Series card E1 channel 14 connector type: 0:RJ-48C 1:BNC
1.3.6.1.4.1.4756.20.361.20.1.73Columnfa16e1et100E1Ch15ConnTypeRemoteread-onlycurrent16E1-ET100(T/S) Series card E1 channel 15 connector type: 0:RJ-48C 1:BNC
1.3.6.1.4.1.4756.20.361.20.1.74Columnfa16e1et100E1Ch16ConnTypeRemoteread-onlycurrent16E1-ET100(T/S) Series card E1 channel 16 connector type: 0:RJ-48C 1:BNC
1.3.6.1.4.1.4756.20.361.20.1.75Columnfa16e1et100E1Ch1RAIRemoteread-onlycurrent16E1-ET100(T/S) Series card E1 channel 1 RAI status: 0:No 1:Yes
1.3.6.1.4.1.4756.20.361.20.1.76Columnfa16e1et100E1Ch2RAIRemoteread-onlycurrent16E1-ET100(T/S) Series card E1 channel 2 RAI status: 0:No 1:Yes
1.3.6.1.4.1.4756.20.361.20.1.77Columnfa16e1et100E1Ch3RAIRemoteread-onlycurrent16E1-ET100(T/S) Series card E1 channel 3 RAI status: 0:No 1:Yes
1.3.6.1.4.1.4756.20.361.20.1.78Columnfa16e1et100E1Ch4RAIRemoteread-onlycurrent16E1-ET100(T/S) Series card E1 channel 4 RAI status: 0:No 1:Yes
1.3.6.1.4.1.4756.20.361.20.1.79Columnfa16e1et100E1Ch5RAIRemoteread-onlycurrent16E1-ET100(T/S) Series card E1 channel 5 RAI status: 0:No 1:Yes
1.3.6.1.4.1.4756.20.361.20.1.80Columnfa16e1et100E1Ch6RAIRemoteread-onlycurrent16E1-ET100(T/S) Series card E1 channel 6 RAI status: 0:No 1:Yes
1.3.6.1.4.1.4756.20.361.20.1.81Columnfa16e1et100E1Ch7RAIRemoteread-onlycurrent16E1-ET100(T/S) Series card E1 channel 7 RAI status: 0:No 1:Yes
1.3.6.1.4.1.4756.20.361.20.1.82Columnfa16e1et100E1Ch8RAIRemoteread-onlycurrent16E1-ET100(T/S) Series card E1 channel 8 RAI status: 0:No 1:Yes
1.3.6.1.4.1.4756.20.361.20.1.83Columnfa16e1et100E1Ch9RAIRemoteread-onlycurrent16E1-ET100(T/S) Series card E1 channel 9 RAI status: 0:No 1:Yes
1.3.6.1.4.1.4756.20.361.20.1.84Columnfa16e1et100E1Ch10RAIRemoteread-onlycurrent16E1-ET100(T/S) Series card E1 channel 10 RAI status: 0:No 1:Yes
1.3.6.1.4.1.4756.20.361.20.1.85Columnfa16e1et100E1Ch11RAIRemoteread-onlycurrent16E1-ET100(T/S) Series card E1 channel 11 RAI status: 0:No 1:Yes
1.3.6.1.4.1.4756.20.361.20.1.86Columnfa16e1et100E1Ch12RAIRemoteread-onlycurrent16E1-ET100(T/S) Series card E1 channel 12 RAI status: 0:No 1:Yes
1.3.6.1.4.1.4756.20.361.20.1.87Columnfa16e1et100E1Ch13RAIRemoteread-onlycurrent16E1-ET100(T/S) Series card E1 channel 13 RAI status: 0:No 1:Yes
1.3.6.1.4.1.4756.20.361.20.1.88Columnfa16e1et100E1Ch14RAIRemoteread-onlycurrent16E1-ET100(T/S) Series card E1 channel 14 RAI status: 0:No 1:Yes
1.3.6.1.4.1.4756.20.361.20.1.89Columnfa16e1et100E1Ch15RAIRemoteread-onlycurrent16E1-ET100(T/S) Series card E1 channel 15 RAI status: 0:No 1:Yes
1.3.6.1.4.1.4756.20.361.20.1.90Columnfa16e1et100E1Ch16RAIRemoteread-onlycurrent16E1-ET100(T/S) Series card E1 channel 16 RAI status: 0:No 1:Yes
1.3.6.1.4.1.4756.20.361.20.1.91Columnfa16e1et100E1Ch1LOMFRemoteread-onlycurrent16E1-ET100(T/S) Series card E1 channel 1 LOMF status: 0:No 1:Yes
1.3.6.1.4.1.4756.20.361.20.1.92Columnfa16e1et100E1Ch2LOMFRemoteread-onlycurrent16E1-ET100(T/S) Series card E1 channel 2 LOMF status: 0:No 1:Yes
1.3.6.1.4.1.4756.20.361.20.1.93Columnfa16e1et100E1Ch3LOMFRemoteread-onlycurrent16E1-ET100(T/S) Series card E1 channel 3 LOMF status: 0:No 1:Yes
1.3.6.1.4.1.4756.20.361.20.1.94Columnfa16e1et100E1Ch4LOMFRemoteread-onlycurrent16E1-ET100(T/S) Series card E1 channel 4 LOMF status: 0:No 1:Yes
1.3.6.1.4.1.4756.20.361.20.1.95Columnfa16e1et100E1Ch5LOMFRemoteread-onlycurrent16E1-ET100(T/S) Series card E1 channel 5 LOMF status: 0:No 1:Yes
1.3.6.1.4.1.4756.20.361.20.1.96Columnfa16e1et100E1Ch6LOMFRemoteread-onlycurrent16E1-ET100(T/S) Series card E1 channel 6 LOMF status: 0:No 1:Yes
1.3.6.1.4.1.4756.20.361.20.1.97Columnfa16e1et100E1Ch7LOMFRemoteread-onlycurrent16E1-ET100(T/S) Series card E1 channel 7 LOMF status: 0:No 1:Yes
1.3.6.1.4.1.4756.20.361.20.1.98Columnfa16e1et100E1Ch8LOMFRemoteread-onlycurrent16E1-ET100(T/S) Series card E1 channel 8 LOMF status: 0:No 1:Yes
1.3.6.1.4.1.4756.20.361.20.1.99Columnfa16e1et100E1Ch9LOMFRemoteread-onlycurrent16E1-ET100(T/S) Series card E1 channel 9 LOMF status: 0:No 1:Yes
1.3.6.1.4.1.4756.20.361.20.1.100Columnfa16e1et100E1Ch10LOMFRemoteread-onlycurrent16E1-ET100(T/S) Series card E1 channel 10 LOMF status: 0:No 1:Yes
1.3.6.1.4.1.4756.20.361.20.1.101Columnfa16e1et100E1Ch11LOMFRemoteread-onlycurrent16E1-ET100(T/S) Series card E1 channel 11 LOMF status: 0:No 1:Yes
1.3.6.1.4.1.4756.20.361.20.1.102Columnfa16e1et100E1Ch12LOMFRemoteread-onlycurrent16E1-ET100(T/S) Series card E1 channel 12 LOMF status: 0:No 1:Yes
1.3.6.1.4.1.4756.20.361.20.1.103Columnfa16e1et100E1Ch13LOMFRemoteread-onlycurrent16E1-ET100(T/S) Series card E1 channel 13 LOMF status: 0:No 1:Yes
1.3.6.1.4.1.4756.20.361.20.1.104Columnfa16e1et100E1Ch14LOMFRemoteread-onlycurrent16E1-ET100(T/S) Series card E1 channel 14 LOMF status: 0:No 1:Yes
1.3.6.1.4.1.4756.20.361.20.1.105Columnfa16e1et100E1Ch15LOMFRemoteread-onlycurrent16E1-ET100(T/S) Series card E1 channel 15 LOMF status: 0:No 1:Yes
1.3.6.1.4.1.4756.20.361.20.1.106Columnfa16e1et100E1Ch16LOMFRemoteread-onlycurrent16E1-ET100(T/S) Series card E1 channel 16 LOMF status: 0:No 1:Yes
1.3.6.1.4.1.4756.20.361.20.1.107Columnfa16e1et100E1Ch1ActiveRemoteread-onlycurrent16E1-ET100(T/S) Series card E1 channel 1 active status: 0:Inactive 1:Active
1.3.6.1.4.1.4756.20.361.20.1.108Columnfa16e1et100E1Ch2ActiveRemoteread-onlycurrent16E1-ET100(T/S) Series card E1 channel 2 active status: 0:Inactive 1:Active
1.3.6.1.4.1.4756.20.361.20.1.109Columnfa16e1et100E1Ch3ActiveRemoteread-onlycurrent16E1-ET100(T/S) Series card E1 channel 3 active status: 0:Inactive 1:Active
1.3.6.1.4.1.4756.20.361.20.1.110Columnfa16e1et100E1Ch4ActiveRemoteread-onlycurrent16E1-ET100(T/S) Series card E1 channel 4 active status: 0:Inactive 1:Active
1.3.6.1.4.1.4756.20.361.20.1.111Columnfa16e1et100E1Ch5ActiveRemoteread-onlycurrent16E1-ET100(T/S) Series card E1 channel 5 active status: 0:Inactive 1:Active
1.3.6.1.4.1.4756.20.361.20.1.112Columnfa16e1et100E1Ch6ActiveRemoteread-onlycurrent16E1-ET100(T/S) Series card E1 channel 6 active status: 0:Inactive 1:Active
1.3.6.1.4.1.4756.20.361.20.1.113Columnfa16e1et100E1Ch7ActiveRemoteread-onlycurrent16E1-ET100(T/S) Series card E1 channel 7 active status: 0:Inactive 1:Active
1.3.6.1.4.1.4756.20.361.20.1.114Columnfa16e1et100E1Ch8ActiveRemoteread-onlycurrent16E1-ET100(T/S) Series card E1 channel 8 active status: 0:Inactive 1:Active
1.3.6.1.4.1.4756.20.361.20.1.115Columnfa16e1et100E1Ch9ActiveRemoteread-onlycurrent16E1-ET100(T/S) Series card E1 channel 9 active status: 0:Inactive 1:Active
1.3.6.1.4.1.4756.20.361.20.1.116Columnfa16e1et100E1Ch10ActiveRemoteread-onlycurrent16E1-ET100(T/S) Series card E1 channel 10 active status: 0:Inactive 1:Active
1.3.6.1.4.1.4756.20.361.20.1.117Columnfa16e1et100E1Ch11ActiveRemoteread-onlycurrent16E1-ET100(T/S) Series card E1 channel 11 active status: 0:Inactive 1:Active
1.3.6.1.4.1.4756.20.361.20.1.118Columnfa16e1et100E1Ch12ActiveRemoteread-onlycurrent16E1-ET100(T/S) Series card E1 channel 12 active status: 0:Inactive 1:Active
1.3.6.1.4.1.4756.20.361.20.1.119Columnfa16e1et100E1Ch13ActiveRemoteread-onlycurrent16E1-ET100(T/S) Series card E1 channel 13 active status: 0:Inactive 1:Active
1.3.6.1.4.1.4756.20.361.20.1.120Columnfa16e1et100E1Ch14ActiveRemoteread-onlycurrent16E1-ET100(T/S) Series card E1 channel 14 active status: 0:Inactive 1:Active
1.3.6.1.4.1.4756.20.361.20.1.121Columnfa16e1et100E1Ch15ActiveRemoteread-onlycurrent16E1-ET100(T/S) Series card E1 channel 15 active status: 0:Inactive 1:Active
1.3.6.1.4.1.4756.20.361.20.1.122Columnfa16e1et100E1Ch16ActiveRemoteread-onlycurrent16E1-ET100(T/S) Series card E1 channel 16 active status: 0:Inactive 1:Active
1.3.6.1.4.1.4756.20.361.20.1.123Columnfa16e1et100E1Ch1LoopBackRemoteread-writecurrent16E1-ET100(T/S) Series card port E1 channel 1 loop back: 0:Off 2:RLB (Max used 15 channels)
1.3.6.1.4.1.4756.20.361.20.1.124Columnfa16e1et100E1Ch2LoopBackRemoteread-writecurrent16E1-ET100(T/S) Series card port E1 channel 2 loop back: 0:Off 2:RLB (Max used 15 channels)
1.3.6.1.4.1.4756.20.361.20.1.125Columnfa16e1et100E1Ch3LoopBackRemoteread-writecurrent16E1-ET100(T/S) Series card port E1 channel 3 loop back: 0:Off 2:RLB (Max used 15 channels)
1.3.6.1.4.1.4756.20.361.20.1.126Columnfa16e1et100E1Ch4LoopBackRemoteread-writecurrent16E1-ET100(T/S) Series card port E1 channel 4 loop back: 0:Off 2:RLB (Max used 15 channels)
1.3.6.1.4.1.4756.20.361.20.1.127Columnfa16e1et100E1Ch5LoopBackRemoteread-writecurrent16E1-ET100(T/S) Series card port E1 channel 5 loop back: 0:Off 2:RLB (Max used 15 channels)
1.3.6.1.4.1.4756.20.361.20.1.128Columnfa16e1et100E1Ch6LoopBackRemoteread-writecurrent16E1-ET100(T/S) Series card port E1 channel 6 loop back: 0:Off 2:RLB (Max used 15 channels)
1.3.6.1.4.1.4756.20.361.20.1.129Columnfa16e1et100E1Ch7LoopBackRemoteread-writecurrent16E1-ET100(T/S) Series card port E1 channel 7 loop back: 0:Off 2:RLB (Max used 15 channels)
1.3.6.1.4.1.4756.20.361.20.1.130Columnfa16e1et100E1Ch8LoopBackRemoteread-writecurrent16E1-ET100(T/S) Series card port E1 channel 8 loop back: 0:Off 2:RLB (Max used 15 channels)
1.3.6.1.4.1.4756.20.361.20.1.131Columnfa16e1et100E1Ch9LoopBackRemoteread-writecurrent16E1-ET100(T/S) Series card port E1 channel 9 loop back: 0:Off 2:RLB (Max used 15 channels)
1.3.6.1.4.1.4756.20.361.20.1.132Columnfa16e1et100E1Ch10LoopBackRemoteread-writecurrent16E1-ET100(T/S) Series card port E1 channel 10 loop back: 0:Off 2:RLB (Max used 15 channels)
1.3.6.1.4.1.4756.20.361.20.1.133Columnfa16e1et100E1Ch11LoopBackRemoteread-writecurrent16E1-ET100(T/S) Series card port E1 channel 11 loop back: 0:Off 2:RLB (Max used 15 channels)
1.3.6.1.4.1.4756.20.361.20.1.134Columnfa16e1et100E1Ch12LoopBackRemoteread-writecurrent16E1-ET100(T/S) Series card port E1 channel 12 loop back: 0:Off 2:RLB (Max used 15 channels)
1.3.6.1.4.1.4756.20.361.20.1.135Columnfa16e1et100E1Ch13LoopBackRemoteread-writecurrent16E1-ET100(T/S) Series card port E1 channel 13 loop back: 0:Off 2:RLB (Max used 15 channels)
1.3.6.1.4.1.4756.20.361.20.1.136Columnfa16e1et100E1Ch14LoopBackRemoteread-writecurrent16E1-ET100(T/S) Series card port E1 channel 14 loop back: 0:Off 2:RLB (Max used 15 channels)
1.3.6.1.4.1.4756.20.361.20.1.137Columnfa16e1et100E1Ch15LoopBackRemoteread-writecurrent16E1-ET100(T/S) Series card port E1 channel 15 loop back: 0:Off 2:RLB (Max used 15 channels)
1.3.6.1.4.1.4756.20.361.20.1.138Columnfa16e1et100E1Ch16LoopBackRemoteread-writecurrent16E1-ET100(T/S) Series card port E1 channel 16 loop back: 0:Off 2:RLB (Max used 15 channels)
1.3.6.1.4.1.4756.20.361.20.1.139Columnfa16e1et100FxLinkRemoteread-onlycurrent16E1-ET100S Series card Fiber siganl detect status: 0:Down or Fiber unplugged 1:Up or Singal detected
1.3.6.1.4.1.4756.20.361.20.1.140Columnfa16e1et100FxLaserRemoteread-onlycurrent16E1-ET100S Series card laser status: 0:Normal 1:Error
1.3.6.1.4.1.4756.20.361.20.1.141Columnfa16e1et100FxActiveRemoteread-writecurrent16E1-ET100S Series card Fiber active: 0:Inactive 1:Active
1.3.6.1.4.1.4756.20.361.20.1.142Columnfa16e1et100FxLaserOutputRemoteread-writecurrent16E1-ET100S Series card laser output: 0:disable 1:Enable
1.3.6.1.4.1.4756.20.361.20.1.143Columnfa16e1et100FxOpModeRemoteread-writecurrent16E1-ET100S Series card operation mode: 0:Switch 1:Convert
1.3.6.1.4.1.4756.20.361.20.1.144Columnfa16e1et100UtpLinkRemoteread-onlycurrent16E1-ET100T Series card UTP link status: 0:Link Down 1:Link Up
1.3.6.1.4.1.4756.20.361.20.1.145Columnfa16e1et100UtpStatusRemoteread-onlycurrent16E1-ET100T Series card UTP link mode status: 0:None, Maybe link down 1:Link at 10Mbps, Half duplex 2:Link at 10Mbps, Full duplex 3:Link at 100Mbps, Half duple…
1.3.6.1.4.1.4756.20.361.20.1.146Columnfa16e1et100UtpFlowCtrlStsRemoteread-onlycurrent16E1-ET100T Series card UTP flow control status: 0:Disable 1:Enable
1.3.6.1.4.1.4756.20.361.20.1.147Columnfa16e1et100UtpModeRemoteread-writecurrent16E1-ET100T Series card UTP mode: 0:Disable 1:Enable and autoNegotiation 3:Enable and force to 10Mbps, Half duplex 4:Enable and force to 10Mbps, Full duplex 5:…
1.3.6.1.4.1.4756.20.361.20.1.148Columnfa16e1et100UtpFlowCtrlRemoteread-writecurrent16E1-ET100T Series card UTP flow control: 0:Disable 1:Enable
1.3.6.1.4.1.4756.20.361.20.1.149Columnfa16e1et100SpeedLimitRemoteread-writecurrent16E1-ET100(T/S) Series card speed limit: Limited = this value * 32Kbps, this value is restricted to 0 ~ 3125, 0 to disable
1.3.6.1.4.1.4756.20.361.20.1.150Columnfa16e1et100VlanAwareRemoteread-writecurrent16E1-ET100(T/S) Series card 802.1q VLAN tag aware: 0:Disable 1:Enable
1.3.6.1.4.1.4756.20.361.20.1.151Columnfa16e1et100VlanIDRemoteread-writecurrent16E1-ET100(T/S) Series card VLAN ID: The ID is restricted to 1 ~ 4094
1.3.6.1.4.1.4756.20.361.20.1.152Columnfa16e1et100RemoteDeviceRemoteread-onlycurrentFRM220A-16E1 Series card remote device status: 0:Link Down 1:Link Up
1.3.6.1.4.1.4756.20.361.20.1.153Columnfa16e1et100RemotePowerRemoteread-onlycurrent16E1-ET100(T/S) Series card remote device power status: 0:Normal 1:Power off
1.3.6.1.4.1.4756.20.361.20.1.154Columnfa16e1et100TimingSourceRemoteread-writecurrent16E1-ET100(T/S) Series card clock: 0:Internal oscillatro 1:Recovery from E1 channel 1 2:Recovery from E1 channel 2 3:Recovery from E1 channel 3 4:Recovery from…
1.3.6.1.4.1.4756.20.361.20.1.155Columnfa16e1et100FCSofGFPRemoteread-writecurrent16E1-ET100(T/S) Series card FCS of GFP: 0:Disable 1:Enable
1.3.6.1.4.1.4756.20.361.20.1.156Columnfa16e1et100AutoChAdjustRemoteread-writecurrent16E1-ET100(T/S) Series card auto channel Bdjust: 0:Disable 1:Enable
1.3.6.1.4.1.4756.20.361.20.1.157Columnfa16e1et100PayloadScrambleRemoteread-writecurrent16E1-ET100(T/S) Series card payload scramble: 0:Disable 1:Enable
1.3.6.1.4.1.4756.20.361.20.1.158Columnfa16e1et100FailoverRemoteread-writecurrent16E1-ET100(T/S) Series card failover: 0:Disable 1:Enable
1.3.6.1.4.1.4756.20.361.20.1.159Columnfa16e1et100LOMRemoteread-onlycurrent16E1-ET100(T/S) Series card LOM status: 0:No 1:Yes
1.3.6.1.4.1.4756.20.361.20.1.160Columnfa16e1et100SQMRemoteread-onlycurrent16E1-ET100(T/S) Series card SQM status: 0:No 1:Yes
1.3.6.1.4.1.4756.20.361.20.1.161Columnfa16e1et100CRCRemoteread-onlycurrent16E1-ET100(T/S) Series card CRC status: 0:No 1:Yes
1.3.6.1.4.1.4756.20.361.20.1.162Columnfa16e1et100LOARemoteread-onlycurrent16E1-ET100(T/S) Series card LOA status: 0:No 1:Yes
1.3.6.1.4.1.4756.20.361.20.1.163Columnfa16e1et100LFDRemoteread-onlycurrent16E1-ET100(T/S) Series card LFD status: 0:No 1:Yes
1.3.6.1.4.1.4756.20.361.20.1.164Columnfa16e1et100DDTORemoteread-onlycurrent16E1-ET100(T/S) Series card DDTO status: 0:No 1:Yes
1.3.6.1.4.1.4756.20.361.20.1.165Columnfa16e1et100VcatMember1Remoteread-writecurrent16E1-ET100(T/S) Series card VACT member 1: 0:Disable 1:Enable
1.3.6.1.4.1.4756.20.361.20.1.166Columnfa16e1et100VcatMember2Remoteread-writecurrent16E1-ET100(T/S) Series card VACT member 2: 0:Disable 1:Enable
1.3.6.1.4.1.4756.20.361.20.1.167Columnfa16e1et100VcatMember3Remoteread-writecurrent16E1-ET100(T/S) Series card VACT member 3: 0:Disable 1:Enable
1.3.6.1.4.1.4756.20.361.20.1.168Columnfa16e1et100VcatMember4Remoteread-writecurrent16E1-ET100(T/S) Series card VACT member 4: 0:Disable 1:Enable
1.3.6.1.4.1.4756.20.361.20.1.169Columnfa16e1et100VcatMember5Remoteread-writecurrent16E1-ET100(T/S) Series card VACT member 5: 0:Disable 1:Enable
1.3.6.1.4.1.4756.20.361.20.1.170Columnfa16e1et100VcatMember6Remoteread-writecurrent16E1-ET100(T/S) Series card VACT member 6: 0:Disable 1:Enable
1.3.6.1.4.1.4756.20.361.20.1.171Columnfa16e1et100VcatMember7Remoteread-writecurrent16E1-ET100(T/S) Series card VACT member 7: 0:Disable 1:Enable
1.3.6.1.4.1.4756.20.361.20.1.172Columnfa16e1et100VcatMember8Remoteread-writecurrent16E1-ET100(T/S) Series card VACT member 8: 0:Disable 1:Enable
1.3.6.1.4.1.4756.20.361.20.1.173Columnfa16e1et100VcatMember9Remoteread-writecurrent16E1-ET100(T/S) Series card VACT member 9: 0:Disable 1:Enable
1.3.6.1.4.1.4756.20.361.20.1.174Columnfa16e1et100VcatMember10Remoteread-writecurrent16E1-ET100(T/S) Series card VACT member 10: 0:Disable 1:Enable
1.3.6.1.4.1.4756.20.361.20.1.175Columnfa16e1et100VcatMember11Remoteread-writecurrent16E1-ET100(T/S) Series card VACT member 11: 0:Disable 1:Enable
1.3.6.1.4.1.4756.20.361.20.1.176Columnfa16e1et100VcatMember12Remoteread-writecurrent16E1-ET100(T/S) Series card VACT member 12: 0:Disable 1:Enable
1.3.6.1.4.1.4756.20.361.20.1.177Columnfa16e1et100VcatMember13Remoteread-writecurrent16E1-ET100(T/S) Series card VACT member 13: 0:Disable 1:Enable
1.3.6.1.4.1.4756.20.361.20.1.178Columnfa16e1et100VcatMember14Remoteread-writecurrent16E1-ET100(T/S) Series card VACT member 14: 0:Disable 1:Enable
1.3.6.1.4.1.4756.20.361.20.1.179Columnfa16e1et100VcatMember15Remoteread-writecurrent16E1-ET100(T/S) Series card VACT member 15: 0:Disable 1:Enable
1.3.6.1.4.1.4756.20.361.20.1.180Columnfa16e1et100VcatMember16Remoteread-writecurrent16E1-ET100(T/S) Series card VACT member 16: 0:Disable 1:Enable
1.3.6.1.4.1.4756.20.361.20.1.181Columnfa16e1et100SnmpChannel1Remoteread-writecurrent16E1-ET100(T/S) Series card SNMP channel 0: 0:No use 1:Use
1.3.6.1.4.1.4756.20.361.20.1.182Columnfa16e1et100SnmpChannel2Remoteread-writecurrent16E1-ET100(T/S) Series card SNMP channel 1: 0:No use 1:Use
1.3.6.1.4.1.4756.20.361.20.1.183Columnfa16e1et100SnmpChannel3Remoteread-writecurrent16E1-ET100(T/S) Series card SNMP channel 3: 0:No use 1:Use
1.3.6.1.4.1.4756.20.361.20.1.184Columnfa16e1et100SnmpChannel4Remoteread-writecurrent16E1-ET100(T/S) Series card SNMP channel 4: 0:No use 1:Use
1.3.6.1.4.1.4756.20.361.20.1.185Columnfa16e1et100ErrSecRemoteread-onlycurrent16E1-ET100(T/S) Series card, errored seconds of BERT result.
1.3.6.1.4.1.4756.20.361.20.1.186Columnfa16e1et100ErrFreeSecRemoteread-onlycurrent16E1-ET100(T/S) Series card, errored free seconds of BERT result.
1.3.6.1.4.1.4756.20.361.20.1.187Columnfa16e1et100ServErrSecRemoteread-onlycurrent16E1-ET100(T/S) Series card, severely errored seconds of BERT result.
1.3.6.1.4.1.4756.20.361.20.1.188Columnfa16e1et100BertFunctionRemoteread-writecurrent16E1-ET100(T/S) Series card bert function: 0:Disable 1:Enable
1.3.6.1.4.1.4756.20.361.20.1.189Columnfa16e1et100ClrBertDataRemoteread-writecurrent16E1-ET100(T/S) Series card bert data clear: 0:Normal 1:Clear
1.3.6.1.4.1.4756.20.361.20.1.190Columnfa16e1et100BertE1ChannelRemoteread-writecurrent16E1-ET100(T/S) Series card bert E1 channel number: 0:E1 channel 1 1:E1 channel 2 2:E1 channel 3 3:E1 channel 4 4:E1 channel 5 5:E1 channel 6 6:E1 channel 7 7:…
1.3.6.1.4.1.4756.20.361.20.1.191Columnfa16e1et100RmonFunctionRemoteread-writecurrent16E1-ET100(T/S) Series RMON function : 0:Disable 1:Enable
1.3.6.1.4.1.4756.20.361.20.1.192Columnfa16e1et100RmonTxRemoteread-onlycurrent16E1-ET100(T/S) Series card RMON Tx counter.
1.3.6.1.4.1.4756.20.361.20.1.193Columnfa16e1et100RmonRxRemoteread-onlycurrent16E1-ET100(T/S) Series card RMON Rx counter.
1.3.6.1.4.1.4756.20.361.20.1.194Columnfa16e1et100ClrRmonTxRemoteread-writecurrent16E1-ET100(T/S) Series card clear RMON Tx counter: 0:Normal 1:Clear
1.3.6.1.4.1.4756.20.361.20.1.195Columnfa16e1et100ClrRmonRxRemoteread-writecurrent16E1-ET100(T/S) Series card clear RMON Rx counter: 0:Normal 1:Clear
1.3.6.1.4.1.4756.20.361.20.1.196Columnfa16e1et100SfpRemoteread-onlycurrent16E1-ET100(T/S) Series card, SFP existed: 0:No 1:Yes
1.3.6.1.4.1.4756.20.361.20.1.197Columnfa16e1et100SfpVendorRemoteread-onlycurrent16E1-ET100(T/S) Series card, Vendor name of SFP.
1.3.6.1.4.1.4756.20.361.20.1.198Columnfa16e1et100SfpPartNoRemoteread-onlycurrent16E1-ET100(T/S) Series card, Vendor part number of SFP.
1.3.6.1.4.1.4756.20.361.20.1.199Columnfa16e1et100SfpFiberTypeRemoteread-onlycurrent16E1-ET100(T/S) Series card, Fiber Type of SFP.
1.3.6.1.4.1.4756.20.361.20.1.200Columnfa16e1et100SfpTxWaveLenRemoteread-onlycurrent16E1-ET100(T/S) Series card, Tx Wave length of SFP.
1.3.6.1.4.1.4756.20.361.20.1.201Columnfa16e1et100SfpRxWaveLenRemoteread-onlycurrent16E1-ET100(T/S) Series card, Rx Wave length of SFP.
1.3.6.1.4.1.4756.20.361.20.1.202Columnfa16e1et100SfpLinkLenRemoteread-onlycurrent16E1-ET100(T/S) Series card, Link length of SFP.
1.3.6.1.4.1.4756.20.361.20.1.203Columnfa16e1et100SfpModelIDRemoteread-onlycurrent16E1-ET100(T/S) Series card, model ID of SFP.
1.3.6.1.4.1.4756.20.361.20.1.204Columnfa16e1et100SfpVersionRemoteread-onlycurrent16E1-ET100(T/S) Series card, the version of SFP.
1.3.6.1.4.1.4756.20.361.20.1.205Columnfa16e1et100SfpModelTypeRemoteread-onlycurrent16E1-ET100(T/S) Series card, model type of SFP.
1.3.6.1.4.1.4756.20.361.20.1.206Columnfa16e1et100DDInformationRemoteread-onlycurrent16E1-ET100(T/S) Series card, D/D information of SFP Supported: 0:No, 1:Yes
1.3.6.1.4.1.4756.20.361.20.1.207Columnfa16e1et100DDRxSensRemoteread-onlycurrent16E1-ET100(T/S) Series card, Sensitivity of D/D information.
1.3.6.1.4.1.4756.20.361.20.1.208Columnfa16e1et100DDTxPowerRemoteread-onlycurrent16E1-ET100(T/S) Series card, Tx power of D/D information.
1.3.6.1.4.1.4756.20.361.20.1.209Columnfa16e1et100DDRxPowerRemoteread-onlycurrent16E1-ET100(T/S) Series card, Rx power of D/D information.
1.3.6.1.4.1.4756.20.361.20.1.210Columnfa16e1et100DDTempRemoteread-onlycurrent16E1-ET100(T/S) Series card, Temperature of D/D information in degree C.
1.3.6.1.4.1.4756.20.361.20.1.211Columnfa16e1et100DDBiasRemoteread-onlycurrent16E1-ET100(T/S) Series card, BIAS of D/D information.
1.3.6.1.4.1.4756.20.361.20.1.212Columnfa16e1et100DDVoltageRemoteread-onlycurrent16E1-ET100(T/S) Series card, Voltage of D/D information.
1.3.6.1.4.1.4756.20.361.20.1.213Columnfa16e1et100ChannelDefectRemoteread-writecurrent16E1-ET100(T/S) Series card Channel Defect: 0:Disable 4:1E-4 6:1E-6
1.3.6.1.4.1.4756.20.361.20.1.214Columnfa16e1et100LoopDetectionRemoteread-writecurrent16E1-ET100(T/S) Series card Loop Detection: 0:Disable 1:Enable
1.3.6.1.4.1.4756.20.361.20.1.215Columnfa16e1et100LoopCh1Remoteread-onlycurrent16E1-ET100(T/S) Series card E1 channel 1 Loop Check State: 0:No 1:Yes
1.3.6.1.4.1.4756.20.361.20.1.216Columnfa16e1et100LoopCh2Remoteread-onlycurrent16E1-ET100(T/S) Series card E1 channel 2 Loop Check State: 0:No 1:Yes
1.3.6.1.4.1.4756.20.361.20.1.217Columnfa16e1et100LoopCh3Remoteread-onlycurrent16E1-ET100(T/S) Series card E1 channel 3 Loop Check State: 0:No 1:Yes
1.3.6.1.4.1.4756.20.361.20.1.218Columnfa16e1et100LoopCh4Remoteread-onlycurrent16E1-ET100(T/S) Series card E1 channel 4 Loop Check State: 0:No 1:Yes
1.3.6.1.4.1.4756.20.361.20.1.219Columnfa16e1et100LoopCh5Remoteread-onlycurrent16E1-ET100(T/S) Series card E1 channel 5 Loop Check State: 0:No 1:Yes
1.3.6.1.4.1.4756.20.361.20.1.220Columnfa16e1et100LoopCh6Remoteread-onlycurrent16E1-ET100(T/S) Series card E1 channel 6 Loop Check State: 0:No 1:Yes
1.3.6.1.4.1.4756.20.361.20.1.221Columnfa16e1et100LoopCh7Remoteread-onlycurrent16E1-ET100(T/S) Series card E1 channel 7 Loop Check State: 0:No 1:Yes
1.3.6.1.4.1.4756.20.361.20.1.222Columnfa16e1et100LoopCh8Remoteread-onlycurrent16E1-ET100(T/S) Series card E1 channel 8 Loop Check State: 0:No 1:Yes
1.3.6.1.4.1.4756.20.361.20.1.223Columnfa16e1et100LoopCh9Remoteread-onlycurrent16E1-ET100(T/S) Series card E1 channel 9 Loop Check State: 0:No 1:Yes
1.3.6.1.4.1.4756.20.361.20.1.224Columnfa16e1et100LoopCh10Remoteread-onlycurrent16E1-ET100(T/S) Series card E1 channel 10 Loop Check State: 0:No 1:Yes
1.3.6.1.4.1.4756.20.361.20.1.225Columnfa16e1et100LoopCh11Remoteread-onlycurrent16E1-ET100(T/S) Series card E1 channel 11 Loop Check State: 0:No 1:Yes
1.3.6.1.4.1.4756.20.361.20.1.226Columnfa16e1et100LoopCh12Remoteread-onlycurrent16E1-ET100(T/S) Series card E1 channel 12 Loop Check State: 0:No 1:Yes
1.3.6.1.4.1.4756.20.361.20.1.227Columnfa16e1et100LoopCh13Remoteread-onlycurrent16E1-ET100(T/S) Series card E1 channel 13 Loop Check State: 0:No 1:Yes
1.3.6.1.4.1.4756.20.361.20.1.228Columnfa16e1et100LoopCh14Remoteread-onlycurrent16E1-ET100(T/S) Series card E1 channel 14 Loop Check State: 0:No 1:Yes
1.3.6.1.4.1.4756.20.361.20.1.229Columnfa16e1et100LoopCh15Remoteread-onlycurrent16E1-ET100(T/S) Series card E1 channel 15 Loop Check State: 0:No 1:Yes
1.3.6.1.4.1.4756.20.361.20.1.230Columnfa16e1et100LoopCh16Remoteread-onlycurrent16E1-ET100(T/S) Series card E1 channel 16 Loop Check State: 0:No 1:Yes
1.3.6.1.4.1.4756.20.361.20.1.231Columnfa16e1et100DefectCh1Remoteread-onlycurrent16E1-ET100(T/S) Series card E1 channel 1 Defect Status: 0:No 1:Yes
1.3.6.1.4.1.4756.20.361.20.1.232Columnfa16e1et100DefectCh2Remoteread-onlycurrent16E1-ET100(T/S) Series card E1 channel 2 Defect Status: 0:No 1:Yes
1.3.6.1.4.1.4756.20.361.20.1.233Columnfa16e1et100DefectCh3Remoteread-onlycurrent16E1-ET100(T/S) Series card E1 channel 3 Defect Status: 0:No 1:Yes
1.3.6.1.4.1.4756.20.361.20.1.234Columnfa16e1et100DefectCh4Remoteread-onlycurrent16E1-ET100(T/S) Series card E1 channel 4 Defect Status: 0:No 1:Yes
1.3.6.1.4.1.4756.20.361.20.1.235Columnfa16e1et100DefectCh5Remoteread-onlycurrent16E1-ET100(T/S) Series card E1 channel 5 Defect Status: 0:No 1:Yes
1.3.6.1.4.1.4756.20.361.20.1.236Columnfa16e1et100DefectCh6Remoteread-onlycurrent16E1-ET100(T/S) Series card E1 channel 6 Defect Status: 0:No 1:Yes
1.3.6.1.4.1.4756.20.361.20.1.237Columnfa16e1et100DefectCh7Remoteread-onlycurrent16E1-ET100(T/S) Series card E1 channel 7 Defect Status: 0:No 1:Yes
1.3.6.1.4.1.4756.20.361.20.1.238Columnfa16e1et100DefectCh8Remoteread-onlycurrent16E1-ET100(T/S) Series card E1 channel 8 Defect Status: 0:No 1:Yes
1.3.6.1.4.1.4756.20.361.20.1.239Columnfa16e1et100DefectCh9Remoteread-onlycurrent16E1-ET100(T/S) Series card E1 channel 9 Defect Status: 0:No 1:Yes
1.3.6.1.4.1.4756.20.361.20.1.240Columnfa16e1et100DefectCh10Remoteread-onlycurrent16E1-ET100(T/S) Series card E1 channel 10 Defect Status: 0:No 1:Yes
1.3.6.1.4.1.4756.20.361.20.1.241Columnfa16e1et100DefectCh11Remoteread-onlycurrent16E1-ET100(T/S) Series card E1 channel 11 Defect Status: 0:No 1:Yes
1.3.6.1.4.1.4756.20.361.20.1.242Columnfa16e1et100DefectCh12Remoteread-onlycurrent16E1-ET100(T/S) Series card E1 channel 12 Defect Status: 0:No 1:Yes
1.3.6.1.4.1.4756.20.361.20.1.243Columnfa16e1et100DefectCh13Remoteread-onlycurrent16E1-ET100(T/S) Series card E1 channel 13 Defect Status: 0:No 1:Yes
1.3.6.1.4.1.4756.20.361.20.1.244Columnfa16e1et100DefectCh14Remoteread-onlycurrent16E1-ET100(T/S) Series card E1 channel 14 Defect Status: 0:No 1:Yes
1.3.6.1.4.1.4756.20.361.20.1.245Columnfa16e1et100DefectCh15Remoteread-onlycurrent16E1-ET100(T/S) Series card E1 channel 15 Defect Status: 0:No 1:Yes
1.3.6.1.4.1.4756.20.361.20.1.246Columnfa16e1et100DefectCh16Remoteread-onlycurrent16E1-ET100(T/S) Series card E1 channel 16 Defect Status: 0:No 1:Yes
1.3.6.1.4.1.4756.20.361.20.1.247Columnfa16e1et100FxSignalRemoteread-onlycurrent16E1-ET100(T/S) Series card Fiber signal detect(SD): 0:Fiber unplugged 1:Signal detected
1.3.6.1.4.1.4756.20.361.20.1.248Columnfa16e1et100PortResetRemoteread-writecurrent16E1-ET100(T/S) Series card Port Reset: 0:Action 1:Off
1.3.6.1.4.1.4756.20.361.20.1.249Columnfa16e1et100VLANModeRemoteread-writecurrent16E1-ET100(T/S) Series card VLAN mode: 0:MODE2 1:MODE1
1.3.6.1.4.1.4756.20.361.20.1.250Columnfa16e1et100ETagSelectEntryRemoteread-writecurrent16E1-ET100(T/S) Series card ETag select entry:
1.3.6.1.4.1.4756.20.361.20.1.251Columnfa16e1et100ETagMethodRemoteread-writecurrent16E1-ET100(T/S) Series card ETag Method: 0: Intouch 1: Add Tag 2: Remove Tag
1.3.6.1.4.1.4756.20.361.20.1.252Columnfa16e1et100VLANTableVID1Remoteread-writecurrent16E1-ET100(T/S) Series card VLAN Table: VLAN ID1
1.3.6.1.4.1.4756.20.361.20.1.253Columnfa16e1et100VLANTableVID2Remoteread-writecurrent16E1-ET100(T/S) Series card VLAN Table: VLAN ID2
1.3.6.1.4.1.4756.20.361.20.1.254Columnfa16e1et100VLANTableVID3Remoteread-writecurrent16E1-ET100(T/S) Series card VLAN Table: VLAN ID3
1.3.6.1.4.1.4756.20.361.20.1.255Columnfa16e1et100VLANTableVID4Remoteread-writecurrent16E1-ET100(T/S) Series card VLAN Table: VLAN ID4
1.3.6.1.4.1.4756.20.361.20.1.256Columnfa16e1et100VLANTableVID5Remoteread-writecurrent16E1-ET100(T/S) Series card VLAN Table: VLAN ID5
1.3.6.1.4.1.4756.20.361.20.1.257Columnfa16e1et100VLANTableVID6Remoteread-writecurrent16E1-ET100(T/S) Series card VLAN Table: VLAN ID6
1.3.6.1.4.1.4756.20.361.20.1.258Columnfa16e1et100VLANTableVID7Remoteread-writecurrent16E1-ET100(T/S) Series card VLAN Table: VLAN ID7
1.3.6.1.4.1.4756.20.361.20.1.259Columnfa16e1et100VLANTableVID8Remoteread-writecurrent16E1-ET100(T/S) Series card VLAN Table: VLAN ID8
1.3.6.1.4.1.4756.20.361.20.1.260Columnfa16e1et100VLANTableVID9Remoteread-writecurrent16E1-ET100(T/S) Series card VLAN Table: VLAN ID9
1.3.6.1.4.1.4756.20.361.20.1.261Columnfa16e1et100VLANTableVID10Remoteread-writecurrent16E1-ET100(T/S) Series card VLAN Table: VLAN ID10
1.3.6.1.4.1.4756.20.361.20.1.262Columnfa16e1et100VLANTableVID11Remoteread-writecurrent16E1-ET100(T/S) Series card VLAN Table: VLAN ID11
1.3.6.1.4.1.4756.20.361.20.1.263Columnfa16e1et100VLANTableVID12Remoteread-writecurrent16E1-ET100(T/S) Series card VLAN Table: VLAN ID12
1.3.6.1.4.1.4756.20.361.20.1.264Columnfa16e1et100VLANTableVID13Remoteread-writecurrent16E1-ET100(T/S) Series card VLAN Table: VLAN ID13
1.3.6.1.4.1.4756.20.361.20.1.265Columnfa16e1et100VLANTableVID14Remoteread-writecurrent16E1-ET100(T/S) Series card VLAN Table: VLAN ID14
1.3.6.1.4.1.4756.20.361.20.1.266Columnfa16e1et100VLANTableVID15Remoteread-writecurrent16E1-ET100(T/S) Series card VLAN Table: VLAN ID15
1.3.6.1.4.1.4756.20.361.20.1.267Columnfa16e1et100VLANTableVID16Remoteread-writecurrent16E1-ET100(T/S) Series card VLAN Table: VLAN ID16
1.3.6.1.4.1.4756.20.370Nodef10GECards
1.3.6.1.4.1.4756.20.370.20Tablef10GETablenot-accessiblecurrentA list of local FRM220-10GE card entries. The number of entries is f10GE.
1.3.6.1.4.1.4756.20.370.20.1Rowf10GEEntrynot-accessiblecurrentAn entry containing management information applicable to a particular local FRM220-10GE card.
1.3.6.1.4.1.4756.20.370.20.1.1Columnf10GEChassisIndexread-onlycurrentA unique value for each local card. It is the chassis location number.
1.3.6.1.4.1.4756.20.370.20.1.2Columnf10GESlotIndexread-onlycurrentA unique value for each local card. It is the slot location number.
1.3.6.1.4.1.4756.20.370.20.1.3Columnf10GECardHWVerread-onlycurrentLocal FRM220-10GE card hardware version x.xxx
1.3.6.1.4.1.4756.20.370.20.1.4Columnf10GECardFWVerread-onlycurrentLocal FRM220-10GE card firmware version x.xxx
1.3.6.1.4.1.4756.20.370.20.1.5Columnf10GECardCPLDVerread-onlycurrentLocal FRM220-10GE card CPLD version x.xxx
1.3.6.1.4.1.4756.20.370.20.1.6Columnf10GECardFPGAVerread-onlycurrentLocal FRM220-10GE card FPGA version x.xxx
1.3.6.1.4.1.4756.20.370.20.1.7Columnf10GEModelread-onlycurrentLocal CardType: 0:FRM220-10GETX 1:FRM220-10GETS
1.3.6.1.4.1.4756.20.370.20.1.8Columnf10GEPortActiveread-writecurrentLocal FRM220-10GE card active: 0:Inactive 1:Active
1.3.6.1.4.1.4756.20.370.20.1.9Columnf10GEPortResetread-writecurrentForce local FRM220-10GE card to reset mode: 0:Off 1:Action
1.3.6.1.4.1.4756.20.370.20.1.10Columnf10GESettoDefaultread-writecurrentForce local FRM220-10GE card set to default mode: 0:Off 1:Action
1.3.6.1.4.1.4756.20.370.20.1.11Columnf10GEUtpActiveread-writecurrentForce local FRM220-10GE card UTP active: 0:Disalbe 1:Enable
1.3.6.1.4.1.4756.20.370.20.1.12Columnf10GEUtpLinkread-onlycurrentLocal FRM220-10GE card UTP link status: 0:Down 1:Up
1.3.6.1.4.1.4756.20.370.20.1.13Columnf10GEUtpNegoread-writecurrentLocal FRM220-10GE card UTP negotiation: 0:Manual 1:Auto
1.3.6.1.4.1.4756.20.370.20.1.14Columnf10GEUtpSpeedread-writecurrentLocal FRM220-10GE card UTP speed: 0:10G Base-T 1:1000 Base-T 2:100 Base-TX
1.3.6.1.4.1.4756.20.370.20.1.15Columnf10GEUtpSpeedSTSread-onlycurrentLocal FRM220-10GE card UTP speed status: 0:10G Base-T 1:1000 Base-T 2:100 Base-TX 3:No Link
1.3.6.1.4.1.4756.20.370.20.1.16Columnf10GEUtpShortReachread-writecurrentLocal FRM220-10GE card UTP short reach: 0:Disable 1:Enable
1.3.6.1.4.1.4756.20.370.20.1.17Columnf10GEUtpLoopbackread-writecurrentLocal FRM220-10GE card UTP loop back: 0:Disable 1:Enable
1.3.6.1.4.1.4756.20.370.20.1.18Columnf10GEUtpCableLengthread-onlycurrentLocal FRM220-10GE card UTP cable length:
1.3.6.1.4.1.4756.20.370.20.1.19Columnf10GEFxActiveread-writecurrentLocal FRM220-10GE card fiber active: 0:Disable 1:Enable
1.3.6.1.4.1.4756.20.370.20.1.20Columnf10GEFxLinkread-onlycurrentLocal FRM220-10GE card fiber link status: 0:Down 1:Up
1.3.6.1.4.1.4756.20.370.20.1.21Columnf10GEFxSpeedSTSread-onlycurrentLocal FRM220-10GE card fiber speed status: 0:No link 1:10G 2:1000M 3:100M
1.3.6.1.4.1.4756.20.370.20.1.22Columnf10GEFxDDMread-onlycurrentLocal FRM220-10GE card fiber DDM status: 0:None 1:DDM
1.3.6.1.4.1.4756.20.370.20.1.23Columnf10GEFxTxFailread-onlycurrentLocal FRM220-10GE card fiber Tx fail: 0:Normal 1:Detect
1.3.6.1.4.1.4756.20.370.20.1.24Columnf10GEFxAlsread-writecurrentLocal FRM220-10GE card fiber auto laser shutdown: 0:Disable 1:Enable
1.3.6.1.4.1.4756.20.370.20.1.25Columnf10GEFxLoopbackread-writecurrentLocal FRM220-10GE card fiber loopback: 0:Disable 1:Enable
1.3.6.1.4.1.4756.20.370.20.1.26Columnf10GELfpModeread-writecurrentLocal FRM220-10GE card Link Fault Pass-through mode: 0:Disable 1:Enable
1.3.6.1.4.1.4756.20.370.20.1.27Columnf10GEThermalread-writecurrentLocal FRM220-10GE card thermal protection: 0:80 1:90 2:100 3:110
1.3.6.1.4.1.4756.20.370.20.1.28Columnf10GETempSTSread-onlycurrentLocal FRM220-10GE card temperature status : 0:Normal 1:Over
1.3.6.1.4.1.4756.20.370.20.1.29Columnf10GECurrentTempread-onlycurrentLocal FRM220-10GE card current temperature
1.3.6.1.4.1.4756.20.370.20.1.30Columnf10GEAlarmread-onlycurrentLocal FRM220-10GE card alarm : 0:Off 1:On
1.3.6.1.4.1.4756.20.370.20.1.31Columnf10GEFxDDread-onlycurrentLocal FRM220-10GE card fiber Digital Diagnostic function: 0:No 1:Yes
1.3.6.1.4.1.4756.20.370.20.1.32Columnf10GEDDVendorread-onlycurrentLocal FRM220-10GE card fiber D/D information: Vendor name
1.3.6.1.4.1.4756.20.370.20.1.33Columnf10GEDDPartNoread-onlycurrentLocal FRM220-10GE card fiber D/D information: Vendor part number
1.3.6.1.4.1.4756.20.370.20.1.34Columnf10GEDDFiberTyperead-onlycurrentLocal FRM220-10GE card fiber D/D information: Fiber Type
1.3.6.1.4.1.4756.20.370.20.1.35Columnf10GEDDWaveLenread-onlycurrentLocal FRM220-10GE card fiber D/D information: Wave length
1.3.6.1.4.1.4756.20.370.20.1.36Columnf10GEDDWaveLen2read-onlycurrentLocal FRM220-10GE card fiber D/D information: Wave length 2
1.3.6.1.4.1.4756.20.370.20.1.37Columnf10GEDDLinkLenread-onlycurrentLocal FRM220-10GE card fiber D/D information: Link length
1.3.6.1.4.1.4756.20.370.20.1.38Columnf10GEDDLenUnitread-onlycurrentLocal FRM220-10GE card fiber D/D information: Length Unit
1.3.6.1.4.1.4756.20.370.20.1.39Columnf10GEDDStatusread-onlycurrentLocal FRM220-10GE card fiber D/D information: Status Support
1.3.6.1.4.1.4756.20.370.20.1.40Columnf10GEDDRxSensread-onlycurrentLocal FRM220-10GE card fiber D/D information: Rx Sensitivity
1.3.6.1.4.1.4756.20.370.20.1.41Columnf10GEDDTxPWRread-onlycurrentLocal FRM220-10GE card fiber D/D information: Tx power
1.3.6.1.4.1.4756.20.370.20.1.42Columnf10GEDDRxPWRread-onlycurrentLocal FRM220-10GE card fiber D/D information: Rx power
1.3.6.1.4.1.4756.20.370.20.1.43Columnf10GEDDTempread-onlycurrentLocal FRM220-10GE card fiber D/D information: Temperature in degree C
1.3.6.1.4.1.4756.20.370.20.1.44Columnf10GEDDPWRMarginread-onlycurrentLocal FRM220-10GE card fiber D/D information: Power margin
1.3.6.1.4.1.4756.20.370.20.1.45Columnf10GEDDPWRLossread-onlycurrentLocal FRM220-10GE card fiber D/D information: Power loss
1.3.6.1.4.1.4756.20.380Nodeeoe1GLocalCards
1.3.6.1.4.1.4756.20.380.20Tableeoe1GLocalTablenot-accessiblecurrentA list of local FRM220-EOE1/G card entries. The number of entries is eoe1G-No-L.
1.3.6.1.4.1.4756.20.380.20.1Roweoe1GLocalEntrynot-accessiblecurrentAn entry containing management information applicable to a particular local FRM220-Eoe1G series card.
1.3.6.1.4.1.4756.20.380.20.1.1Columneoe1GChassisIndexLocalread-onlycurrentA unique value for each card. It starts from 0 to 9 contiguously.
1.3.6.1.4.1.4756.20.380.20.1.2Columneoe1GSlotIndexLocalread-onlycurrentA unique value for each card. It starts from 1 to 20 contiguously.
1.3.6.1.4.1.4756.20.380.20.1.3Columneoe1GCardHWVerLocalread-onlycurrentEoe1/G Series card hardware version x.xxx
1.3.6.1.4.1.4756.20.380.20.1.4Columneoe1GCardFWVerLocalread-onlycurrentEoe1/G Series card firmware version x.xxx
1.3.6.1.4.1.4756.20.380.20.1.5Columneoe1GCardCPLDVerLocalread-onlycurrentEoe1/G Series card CPLD version x.xxx
1.3.6.1.4.1.4756.20.380.20.1.6Columneoe1GCardFPGAVerLocalread-onlycurrentEoe1/G Series card FPGA version x.xxx
1.3.6.1.4.1.4756.20.380.20.1.7Columneoe1GPortResetLocalread-writecurrentEoe1/G Series card system status: 0:Off 1:Trigger
1.3.6.1.4.1.4756.20.380.20.1.8Columneoe1GSetToDefaultLocalread-writecurrentEoe1/G Series card port set to default: 0:Off 1:Trigger
1.3.6.1.4.1.4756.20.380.20.1.9Columneoe1GLOSLocalread-onlycurrentEoe1/G Series card LOS status: 0:No 1:Yes
1.3.6.1.4.1.4756.20.380.20.1.10Columneoe1GLOFLocalread-onlycurrentEoe1/G Series card LOF status: 0:No 1:Yes
1.3.6.1.4.1.4756.20.380.20.1.11Columneoe1GAISLocalread-onlycurrentEoe1/G Series card AIS status: 0:No 1:Yes
1.3.6.1.4.1.4756.20.380.20.1.12Columneoe1GRAILocalread-onlycurrentEoe1/G Series card RAI status: 0:No 1:Yes
1.3.6.1.4.1.4756.20.380.20.1.13Columneoe1GCRCLocalread-onlycurrentEoe1/G Series card CRC status: 0:No 1:Yes
1.3.6.1.4.1.4756.20.380.20.1.14Columneoe1GBPVLocalread-onlycurrentEoe1/G Series card BPV status: 0:No 1:Yes
1.3.6.1.4.1.4756.20.380.20.1.15Columneoe1GLoopStatusLocalread-onlycurrentEoe1/G Series card Loop status: 0:No 1:Yes
1.3.6.1.4.1.4756.20.380.20.1.16Columneoe1GE1ModeLocalread-writecurrentEoe1/G Series card E1 mode: 0:Unframe 1:Frame
1.3.6.1.4.1.4756.20.380.20.1.17Columneoe1GE1LoopBackLocalread-writecurrentEoe1/G Series card E1 loopback : 0:OFF 1:LLB 2:RLB
1.3.6.1.4.1.4756.20.380.20.1.18Columneoe1GE1LoopDetectionLocalread-writecurrentEoe1/G Series card E1 loop detection: 0:Disable 1:Enalbe
1.3.6.1.4.1.4756.20.380.20.1.19Columneoe1GE1HDLCLocalread-writecurrentEoe1/G Series card E1 HDLC: 0:Inverse 1:Consisten
1.3.6.1.4.1.4756.20.380.20.1.20Columneoe1GTimingSourceLocalread-writecurrentEoe1/G Series card timing source: 0:Recovery from E1 receive 1:Internal oscillator
1.3.6.1.4.1.4756.20.380.20.1.21Columneoe1GFailOverLocalread-writecurrentEoe1/G Series card failover: 0:Disalbe 1:Enable
1.3.6.1.4.1.4756.20.380.20.1.22Columneoe1GEncapsulationLocalread-writecurrentEoe1/G Series card encapsulation: 0:GFP 1:HDLC
1.3.6.1.4.1.4756.20.380.20.1.23Columneoe1GNetManageLocalread-writecurrentEoe1/G Series card net manage: 0:Disable 1:Enable
1.3.6.1.4.1.4756.20.380.20.1.24Columneoe1GTagLocalread-writecurrentEoe1/G Series card tag mode: 0:Untag 1:tag 2:No Touch
1.3.6.1.4.1.4756.20.380.20.1.25Columneoe1GInsertLocalread-writecurrentEoe1/G Series card insert mode: 0:Disable 1:Enable
1.3.6.1.4.1.4756.20.380.20.1.26Columneoe1GUtpLinkLocalread-onlycurrentEoe1/G Series card UTP link status: 0:Down 1:Up
1.3.6.1.4.1.4756.20.380.20.1.27Columneoe1GUtpActiveLocalread-writecurrentEoe1/G Series card UTP port active: 0:Disable 1:Enable
1.3.6.1.4.1.4756.20.380.20.1.28Columneoe1GUtpNegoStatusLocalread-onlycurrentEoe1/G Series card UTP negoiation status: 0:Manual 1:Auto
1.3.6.1.4.1.4756.20.380.20.1.29Columneoe1GUtpSpeedStatusLocalread-onlycurrentEoe1/G Series card UTP speed status: 0:10M 1:100M
1.3.6.1.4.1.4756.20.380.20.1.30Columneoe1GUtpDuplexStatusLocalread-onlycurrentEoe1/G Series card UTP duplex status: 0:Half 1:Full
1.3.6.1.4.1.4756.20.380.20.1.31Columneoe1GUtpNegoLocalread-writecurrentEoe1/G Series card UTP negoiation mode: 0:Manual 1:Auto
1.3.6.1.4.1.4756.20.380.20.1.32Columneoe1GUtpSpeedLocalread-writecurrentEoe1/G Series card UTP speed mode: 0:10M 1:100M
1.3.6.1.4.1.4756.20.380.20.1.33Columneoe1GUtpDuplexLocalread-writecurrentEoe1/G Series card UTP duplex mode: 0:Half 1:Full
1.3.6.1.4.1.4756.20.380.20.1.34Columneoe1GUtpFlowControlLocalread-writecurrentEoe1/G Series card UTP flow control mode: 0:Disable 1:Enable
1.3.6.1.4.1.4756.20.380.20.1.35Columneoe1GBandwidthFUNLocalread-writecurrentEoe1/G Series card bandwidth mode: 1:disable(0), 2:32k*N(0~255)(1), 3:521k*N(0~200)(2),
1.3.6.1.4.1.4756.20.380.20.1.36Columneoe1GBandwidthLocalread-writecurrentEoe1/G Series bandwidth: bandwidth mode is 32k*N , The bandwidth is restricted to 0 ~ 255 bandwidth mode is 512k*N , The bandwidth is restricted to 0 ~ 200
1.3.6.1.4.1.4756.20.380.20.1.37Columneoe1GBandwidthSpeedLocalread-onlycurrentEoe1/G Series bandwidthspeed:
1.3.6.1.4.1.4756.20.380.20.1.38Columneoe1GVlanFUNLocalread-writecurrentEoe1/G Series card Vlan mode: 0:Disable 1:Enable
1.3.6.1.4.1.4756.20.380.20.1.39Columneoe1GVlanIDLocalread-writecurrentEoe1/G Series card VLAN ID: The ID is restricted to 1 ~ 4095
1.3.6.1.4.1.4756.20.380.20.1.40Columneoe1GRemoteLinkLocalread-onlycurrentEoe1/G Series card remote link status: 0:Down 1:Up
1.3.6.1.4.1.4756.20.380.20.1.41Columneoe1GRemotePWRLocalread-onlycurrentEoe1/G Series card remote power status: 0:Normal 1:Power Off
1.3.6.1.4.1.4756.20.380.20.1.42Columneoe1GBertFUNLocalread-writecurrentEoe1/G Series card bert mode: 0:Disable 1:Enable
1.3.6.1.4.1.4756.20.380.20.1.43Columneoe1GBertClearLocalread-writecurrentEoe1/G Series card bert data clear: 0:Normal 1:Clear
1.3.6.1.4.1.4756.20.380.20.1.44Columneoe1GLSBToESLocalread-onlycurrentEoe1/G) Series card, errored seconds of BERT result.
1.3.6.1.4.1.4756.20.380.20.1.45Columneoe1GLSBToSESLocalread-onlycurrent5E1-ET100(T/S) Series card, severely errored seconds of BERT result.
1.3.6.1.4.1.4756.20.380.20.1.46Columneoe1GRmonFUNLocalread-writecurrentEoe1/G Series card Rmon mode: 0:Disable 1:Enable
1.3.6.1.4.1.4756.20.380.20.1.47Columneoe1GRmonRxPKTClearLocalread-writecurrentEoe1/G Series card rmon rx packet clear: 0:Normal 1:Clear
1.3.6.1.4.1.4756.20.380.20.1.48Columneoe1GRmonRxByteClearLocalread-writecurrentEoe1/G Series card rmon rx byte clear: 0:Normal 1:Clear
1.3.6.1.4.1.4756.20.380.20.1.49Columneoe1GRmonRxPKTLocalread-onlycurrentEoe1/G Series card RMON Rx packet counter.
1.3.6.1.4.1.4756.20.380.20.1.50Columneoe1GRmonRxByteLocalread-onlycurrentEoe1/G Series card RMON Rx byte counter.
1.3.6.1.4.1.4756.20.381Nodeeoe1GRemoteCards
1.3.6.1.4.1.4756.20.381.20Tableeoe1GRemoteTablenot-accessiblecurrentA list of local FRM220-EOE1/G card entries. The number of entries is eoe1G-No-L.
1.3.6.1.4.1.4756.20.381.20.1Roweoe1GRemoteEntrynot-accessiblecurrentAn entry containing management information applicable to a particular local FRM220-Eoe1G series card.
1.3.6.1.4.1.4756.20.381.20.1.1Columneoe1GChassisIndexRemoteread-onlycurrentA unique value for each card. It starts from 0 to 9 contiguously.
1.3.6.1.4.1.4756.20.381.20.1.2Columneoe1GSlotIndexRemoteread-onlycurrentA unique value for each card. It starts from 1 to 20 contiguously.
1.3.6.1.4.1.4756.20.381.20.1.3Columneoe1GCardHWVerRemoteread-onlycurrentEoe1/G Series card hardware version x.xxx
1.3.6.1.4.1.4756.20.381.20.1.4Columneoe1GCardFWVerRemoteread-onlycurrentEoe1/G Series card firmware version x.xxx
1.3.6.1.4.1.4756.20.381.20.1.5Columneoe1GCardCPLDVerRemoteread-onlycurrentEoe1/G Series card CPLD version x.xxx
1.3.6.1.4.1.4756.20.381.20.1.6Columneoe1GCardFPGAVerRemoteread-onlycurrentEoe1/G Series card FPGA version x.xxx
1.3.6.1.4.1.4756.20.381.20.1.7Columneoe1GPortResetRemoteread-writecurrentEoe1/G Series card system status: 0:Off 1:Trigger
1.3.6.1.4.1.4756.20.381.20.1.8Columneoe1GSetToDefaultRemoteread-writecurrentEoe1/G Series card port set to default: 0:Off 1:Trigger
1.3.6.1.4.1.4756.20.381.20.1.9Columneoe1GLOSRemoteread-onlycurrentEoe1/G Series card LOS status: 0:No 1:Yes
1.3.6.1.4.1.4756.20.381.20.1.10Columneoe1GLOFRemoteread-onlycurrentEoe1/G Series card LOF status: 0:No 1:Yes
1.3.6.1.4.1.4756.20.381.20.1.11Columneoe1GAISRemoteread-onlycurrentEoe1/G Series card AIS status: 0:No 1:Yes
1.3.6.1.4.1.4756.20.381.20.1.12Columneoe1GRAIRemoteread-onlycurrentEoe1/G Series card RAI status: 0:No 1:Yes
1.3.6.1.4.1.4756.20.381.20.1.13Columneoe1GCRCRemoteread-onlycurrentEoe1/G Series card CRC status: 0:No 1:Yes
1.3.6.1.4.1.4756.20.381.20.1.14Columneoe1GBPVRemoteread-onlycurrentEoe1/G Series card BPV status: 0:No 1:Yes
1.3.6.1.4.1.4756.20.381.20.1.15Columneoe1GLoopStatusRemoteread-onlycurrentEoe1/G Series card Loop status: 0:No 1:Yes
1.3.6.1.4.1.4756.20.381.20.1.16Columneoe1GE1ModeRemoteread-writecurrentEoe1/G Series card E1 mode: 0:Unframe 1:Frame
1.3.6.1.4.1.4756.20.381.20.1.17Columneoe1GE1LoopDetectionRemoteread-writecurrentEoe1/G Series card E1 loop detection: 0:Disable 1:Enalbe
1.3.6.1.4.1.4756.20.381.20.1.18Columneoe1GE1HDLCRemoteread-writecurrentEoe1/G Series card E1 HDLC: 0:Inverse 1:Consisten
1.3.6.1.4.1.4756.20.381.20.1.19Columneoe1GTimingSourceRemoteread-writecurrentEoe1/G Series card timing source: 0:Recovery from E1 receive 1:Internal oscillator
1.3.6.1.4.1.4756.20.381.20.1.20Columneoe1GFailOverRemoteread-writecurrentEoe1/G Series card failover: 0:Disalbe 1:Enable
1.3.6.1.4.1.4756.20.381.20.1.21Columneoe1GEncapsulationRemoteread-writecurrentEoe1/G Series card encapsulation: 0:GFP 1:HDLC
1.3.6.1.4.1.4756.20.381.20.1.22Columneoe1GNetManageRemoteread-writecurrentEoe1/G Series card net manage: 0:Disable 1:Enable
1.3.6.1.4.1.4756.20.381.20.1.23Columneoe1GTagRemoteread-writecurrentEoe1/G Series card tag mode: 0:Untag 1:tag 2:No Touch
1.3.6.1.4.1.4756.20.381.20.1.24Columneoe1GInsertRemoteread-writecurrentEoe1/G Series card insert mode: 0:Disable 1:Enable
1.3.6.1.4.1.4756.20.381.20.1.25Columneoe1GUtpLinkRemoteread-onlycurrentEoe1/G Series card UTP link status: 0:Down 1:Up
1.3.6.1.4.1.4756.20.381.20.1.26Columneoe1GUtpActiveRemoteread-writecurrentEoe1/G Series card UTP port active: 0:Disable 1:Enable
1.3.6.1.4.1.4756.20.381.20.1.27Columneoe1GUtpNegoStatusRemoteread-onlycurrentEoe1/G Series card UTP negoiation status: 0:Manual 1:Auto
1.3.6.1.4.1.4756.20.381.20.1.28Columneoe1GUtpSpeedStatusRemoteread-onlycurrentEoe1/G Series card UTP speed status: 0:10M 1:100M
1.3.6.1.4.1.4756.20.381.20.1.29Columneoe1GUtpDuplexStatusRemoteread-onlycurrentEoe1/G Series card UTP duplex status: 0:Half 1:Full
1.3.6.1.4.1.4756.20.381.20.1.30Columneoe1GUtpNegoRemoteread-writecurrentEoe1/G Series card UTP negoiation mode: 0:Manual 1:Auto
1.3.6.1.4.1.4756.20.381.20.1.31Columneoe1GUtpSpeedRemoteread-writecurrentEoe1/G Series card UTP speed mode: 0:10M 1:100M
1.3.6.1.4.1.4756.20.381.20.1.32Columneoe1GUtpDuplexRemoteread-writecurrentEoe1/G Series card UTP duplex mode: 0:Half 1:Full
1.3.6.1.4.1.4756.20.381.20.1.33Columneoe1GUtpFlowControlRemoteread-writecurrentEoe1/G Series card UTP flow control mode: 0:Disable 1:Enable
1.3.6.1.4.1.4756.20.381.20.1.34Columneoe1GBandwidthFUNRemoteread-writecurrentEoe1/G Series card bandwidth mode: 1:disable(0), 2:32k*N(0~255)(1), 3:521k*N(0~200)(2),
1.3.6.1.4.1.4756.20.381.20.1.35Columneoe1GBandwidthRemoteread-writecurrentEoe1/G Series bandwidth: bandwidth mode is 32k*N , The bandwidth is restricted to 0 ~ 255 bandwidth mode is 512k*N , The bandwidth is restricted to 0 ~ 200
1.3.6.1.4.1.4756.20.381.20.1.36Columneoe1GBandwidthSpeedRemoteread-onlycurrentEoe1/G Series bandwidthspeed:
1.3.6.1.4.1.4756.20.381.20.1.37Columneoe1GVlanFUNRemoteread-writecurrentEoe1/G Series card Vlan mode: 0:Disable 1:Enable
1.3.6.1.4.1.4756.20.381.20.1.38Columneoe1GVlanIDRemoteread-writecurrentEoe1/G Series card VLAN ID: The ID is restricted to 1 ~ 4095
1.3.6.1.4.1.4756.20.381.20.1.39Columneoe1GRemoteLinkRemoteread-onlycurrentEoe1/G Series card remote link status: 0:Down 1:Up
1.3.6.1.4.1.4756.20.381.20.1.40Columneoe1GRemotePWRRemoteread-onlycurrentEoe1/G Series card remote power status: 0:Normal 1:Power Off
1.3.6.1.4.1.4756.20.381.20.1.41Columneoe1GRmonFUNRemoteread-writecurrentEoe1/G Series card Rmon mode: 0:Disable 1:Enable
1.3.6.1.4.1.4756.20.381.20.1.42Columneoe1GRmonRxPKTClearRemoteread-writecurrentEoe1/G Series card rmon rx packet clear: 0:Normal 1:Clear
1.3.6.1.4.1.4756.20.381.20.1.43Columneoe1GRmonRxByteClearRemoteread-writecurrentEoe1/G Series card rmon rx byte clear: 0:Normal 1:Clear
1.3.6.1.4.1.4756.20.381.20.1.44Columneoe1GRmonRxPKTRemoteread-onlycurrentEoe1/G Series card RMON Rx packet counter.
1.3.6.1.4.1.4756.20.381.20.1.45Columneoe1GRmonRxByteRemoteread-onlycurrentEoe1/G Series card RMON Rx byte counter.
1.3.6.1.4.1.4756.20.390Nodef1000DSCards
1.3.6.1.4.1.4756.20.390.20Tablef1000DSTablenot-accessiblecurrentA list of FRM220-f1000DS card entries.
1.3.6.1.4.1.4756.20.390.20.1Rowf1000DSEntrynot-accessiblecurrentAn entry containing management information applicable to a particular local FRM220-f1000DS card.
1.3.6.1.4.1.4756.20.390.20.1.1Columnf1000DSChassisIndexread-onlycurrentA unique value for each local card. It is the chassis location number.
1.3.6.1.4.1.4756.20.390.20.1.2Columnf1000DSSlotIndexread-onlycurrentA unique value for each local card. It is the slot location number.
1.3.6.1.4.1.4756.20.390.20.1.3Columnf1000DSCardHWVerread-onlycurrentFRM220-f1000DS card hardware version x.xxx
1.3.6.1.4.1.4756.20.390.20.1.4Columnf1000DSCardFWVerread-onlycurrentFRM220-f1000DS card firmware version x.xxx
1.3.6.1.4.1.4756.20.390.20.1.5Columnf1000DSCardCPLDVerread-onlycurrentFRM220-f1000DS card CPLD version x.xxx
1.3.6.1.4.1.4756.20.390.20.1.6Columnf1000DSCardFPGAVerread-onlycurrentFRM220-f1000DS card FPGA version x.xxx
1.3.6.1.4.1.4756.20.390.20.1.7Columnf1000DSModelread-onlycurrentFRM220-f1000DS card model
1.3.6.1.4.1.4756.20.390.20.1.8Columnf1000DSPortActiveread-writecurrentFRM220-f1000DS card port active: 0:Disable 1:Enable
1.3.6.1.4.1.4756.20.390.20.1.9Columnf1000DSPortResetread-writecurrentForce FRM220-f1000DS card reset mode: 0:Off 1:Action
1.3.6.1.4.1.4756.20.390.20.1.10Columnf1000DSSetDefaultread-writecurrentForce FRM220-f1000DS card SetDefault mode: 0:Off 1:Action
1.3.6.1.4.1.4756.20.390.20.1.11Columnf1000DSLfpModeread-writecurrentForce FRM220-f1000DS card LFP mode: 0:disable 1:enable
1.3.6.1.4.1.4756.20.390.20.1.12Columnf1000DSFx1Linkread-onlycurrentFRM220-f1000DS card fiber1 link: 0:down 1:up
1.3.6.1.4.1.4756.20.390.20.1.13Columnf1000DSFx1RxActread-writecurrentFRM220-f1000DS card fiber1 Rx Active: 0:Normal 1:Disable
1.3.6.1.4.1.4756.20.390.20.1.14Columnf1000DSFx1Speedread-writecurrentFRM220-f1000DS card fiber1 Speed: 0:Reduced_Bandwidth 1:Full_Bandwidth
1.3.6.1.4.1.4756.20.390.20.1.15Columnf1000DSFx1TxFailread-onlycurrentFRM220-f1000DS card fiber1 Tx Fail: 0:Normal 1:Fail
1.3.6.1.4.1.4756.20.390.20.1.16Columnf1000DSFx1AlsModeread-writecurrentFRM220-f1000DS card fiber1 ALS Mode: 0:Disable 1:Enable
1.3.6.1.4.1.4756.20.390.20.1.17Columnf1000DSFx2Linkread-onlycurrentFRM220-f1000DS card fiber2 link: 0:down 1:up
1.3.6.1.4.1.4756.20.390.20.1.18Columnf1000DSFx2RxActread-writecurrentFRM220-f1000DS card fiber2 Rx Active: 0:Normal 1:Disable
1.3.6.1.4.1.4756.20.390.20.1.19Columnf1000DSFx2Speedread-writecurrentFRM220-f1000DS card fiber2 Speed: 0:Reduced_Bandwidth 1:Full_Bandwidth
1.3.6.1.4.1.4756.20.390.20.1.20Columnf1000DSFx2TxFailread-onlycurrentFRM220-f1000DS card fiber2 Tx Fail: 0:Normal 1:Fail
1.3.6.1.4.1.4756.20.390.20.1.21Columnf1000DSFx2AlsModeread-writecurrentFRM220-f1000DS card fiber2 ALS Mode: 0:Disable 1:Enable
1.3.6.1.4.1.4756.20.390.20.1.22Columnf1000DSFx1DDread-onlycurrentFRM220-f1000DS card fiber1 Digital Diagnostic function: 0:yes 1:no
1.3.6.1.4.1.4756.20.390.20.1.23Columnf1000DSFx1DDVendorread-onlycurrentFRM220-f1000DS card fiber1 D/D information: Vendor name
1.3.6.1.4.1.4756.20.390.20.1.24Columnf1000DSFx1DDPartNoread-onlycurrentFRM220-f1000DS card fiber1 D/D information: Vendor part number
1.3.6.1.4.1.4756.20.390.20.1.25Columnf1000DSFx1DDFiberTyperead-onlycurrentFRM220-f1000DS card fiber1 D/D information: Fiber Type
1.3.6.1.4.1.4756.20.390.20.1.26Columnf1000DSFx1DDWaveLen1read-onlycurrentFRM220-f1000DS card fiber1 D/D information: Wave length 1
1.3.6.1.4.1.4756.20.390.20.1.27Columnf1000DSFx1DDWaveLen2read-onlycurrentFRM220-f1000DS card fiber1 D/D information: Wave length 2
1.3.6.1.4.1.4756.20.390.20.1.28Columnf1000DSFx1DDLinkLenread-onlycurrentFRM220-f1000DS card fiber1 D/D information: Link length
1.3.6.1.4.1.4756.20.390.20.1.29Columnf1000DSFx1DDLenUnitread-onlycurrentFRM220-f1000DS card fiber1 D/D information: Length Unit
1.3.6.1.4.1.4756.20.390.20.1.30Columnf1000DSFx1DDStatusread-onlycurrentFRM220-f1000DS card fiber1 D/D information: Status Support
1.3.6.1.4.1.4756.20.390.20.1.31Columnf1000DSFx1DDRxSensread-onlycurrentFRM220-f1000DS card fiber1 D/D information: Rx Sensitivity
1.3.6.1.4.1.4756.20.390.20.1.32Columnf1000DSFx1DDTxPwrread-onlycurrentFRM220-f1000DS card fiber1 D/D information: Tx power
1.3.6.1.4.1.4756.20.390.20.1.33Columnf1000DSFx1DDRxPwrread-onlycurrentFRM220-f1000DS card fiber1 D/D information: Rx power
1.3.6.1.4.1.4756.20.390.20.1.34Columnf1000DSFx1DDTempread-onlycurrentFRM220-f1000DS card fiber1 D/D information: Temperature in degree C
1.3.6.1.4.1.4756.20.390.20.1.35Columnf1000DSFx1DDPwrMarginread-onlycurrentFRM220-f1000DS card fiber1 D/D information: Power margin
1.3.6.1.4.1.4756.20.390.20.1.36Columnf1000DSFx1DDPwrLossread-onlycurrentFRM220-f1000DS card fiber1 D/D information: Power loss
1.3.6.1.4.1.4756.20.390.20.1.37Columnf1000DSFx2DDread-onlycurrentFRM220-f1000DS card fiber2 Digital Diagnostic function: 0:yes 1:no
1.3.6.1.4.1.4756.20.390.20.1.38Columnf1000DSFx2DDVendorread-onlycurrentFRM220-f1000DS card fiber2 D/D information: Vendor name
1.3.6.1.4.1.4756.20.390.20.1.39Columnf1000DSFx2DDPartNoread-onlycurrentFRM220-f1000DS card fiber2 D/D information: Vendor part number
1.3.6.1.4.1.4756.20.390.20.1.40Columnf1000DSFx2DDFiberTyperead-onlycurrentFRM220-f1000DS card fiber2 D/D information: Fiber Type
1.3.6.1.4.1.4756.20.390.20.1.41Columnf1000DSFx2DDWaveLen1read-onlycurrentFRM220-f1000DS card fiber2 D/D information: Wave length 1
1.3.6.1.4.1.4756.20.390.20.1.42Columnf1000DSFx2DDWaveLen2read-onlycurrentFRM220-f1000DS card fiber2 D/D information: Wave length 2
1.3.6.1.4.1.4756.20.390.20.1.43Columnf1000DSFx2DDLinkLenread-onlycurrentFRM220-f1000DS card fiber2 D/D information: Link length
1.3.6.1.4.1.4756.20.390.20.1.44Columnf1000DSFx2DDLenUnitread-onlycurrentFRM220-f1000DS card fiber2 D/D information: Length Unit
1.3.6.1.4.1.4756.20.390.20.1.45Columnf1000DSFx2DDStatusread-onlycurrentFRM220-f1000DS card fiber2 D/D information: Status Support
1.3.6.1.4.1.4756.20.390.20.1.46Columnf1000DSFx2DDRxSensread-onlycurrentFRM220-f1000DS card fiber2 D/D information: Rx Sensitivity
1.3.6.1.4.1.4756.20.390.20.1.47Columnf1000DSFx2DDTxPwrread-onlycurrentFRM220-f1000DS card fiber2 D/D information: Tx power
1.3.6.1.4.1.4756.20.390.20.1.48Columnf1000DSFx2DDRxPwrread-onlycurrentFRM220-f1000DS card fiber2 D/D information: Rx power
1.3.6.1.4.1.4756.20.390.20.1.49Columnf1000DSFx2DDTempread-onlycurrentFRM220-f1000DS card fiber2 D/D information: Temperature in degree C
1.3.6.1.4.1.4756.20.390.20.1.50Columnf1000DSFx2DDPwrMarginread-onlycurrentFRM220-f1000DS card fiber2 D/D information: Power margin
1.3.6.1.4.1.4756.20.390.20.1.51Columnf1000DSFx2DDPwrLossread-onlycurrentFRM220-f1000DS card fiber2 D/D information: Power loss
1.3.6.1.4.1.4756.20.391NodeprotectionCards
1.3.6.1.4.1.4756.20.391.20TableprotectionTablenot-accessiblecurrentA list of FRM220-protection card entries.
1.3.6.1.4.1.4756.20.391.20.1RowprotectionEntrynot-accessiblecurrentAn entry containing management information applicable to a particular FRM220-protection card.
1.3.6.1.4.1.4756.20.391.20.1.1ColumnprotectionChassisIndexread-onlycurrentA unique value for each local card. It is the chassis location number.
1.3.6.1.4.1.4756.20.391.20.1.2ColumnprotectionSlotIndexread-onlycurrentA unique value for each local card. It is the slot location number.
1.3.6.1.4.1.4756.20.391.20.1.3ColumnprotectionCardHWVerread-onlycurrentFRM220-protection card hardware version x.xxx
1.3.6.1.4.1.4756.20.391.20.1.4ColumnprotectionCardFWVerread-onlycurrentFRM220-protection card firmware version x.xxx
1.3.6.1.4.1.4756.20.391.20.1.5ColumnprotectionCardCPLDVerread-onlycurrentFRM220-protection card CPLD version x.xxx
1.3.6.1.4.1.4756.20.391.20.1.6ColumnprotectionCardFPGAVerread-onlycurrentFRM220-protection card FPGA version x.xxx
1.3.6.1.4.1.4756.20.391.20.1.7ColumnprotectionPortActiveread-writecurrentFRM220-protection card port active: 0:Disable 1:Enable
1.3.6.1.4.1.4756.20.391.20.1.8ColumnprotectionPortResetread-writecurrentForce FRM220-protection card reset mode: 0:Off 1:Action
1.3.6.1.4.1.4756.20.391.20.1.9ColumnprotectionSetDefaultread-writecurrentFRM220- protection card protection set to default: 0:Off 1:Action
1.3.6.1.4.1.4756.20.391.20.1.10ColumnprotectionSecondaryPathSignalLEDread-onlycurrentFRM220- protection card Secondary Path Signal LED: 0:off 1:on
1.3.6.1.4.1.4756.20.391.20.1.11ColumnprotectionWorkingOnSecondaryPathLEDread-onlycurrentFRM220- protection card Working On Secondary Path LED: 0:off 1:on
1.3.6.1.4.1.4756.20.391.20.1.12ColumnprotectionPrimaryPathSignalLEDread-onlycurrentFRM220- protection card Primary Path Signal LED: 0:off 1:on
1.3.6.1.4.1.4756.20.391.20.1.13ColumnprotectionWorkingOnPrimaryPathLEDread-onlycurrentFRM220- protection card Working On Primary Path LED: 0:off 1:on
1.3.6.1.4.1.4756.20.391.20.1.14ColumnprotectionPowerLEDread-onlycurrentFRM220- protection card Power LED: 0:off 1:on
1.3.6.1.4.1.4756.20.391.20.1.15ColumnprotectionSystemOkLEDread-onlycurrentFRM220- protection card System Ok LED: 0:off 1:on
1.3.6.1.4.1.4756.20.391.20.1.16ColumnprotectionWorkingModeread-writecurrentFRM220- protection card Working Mode: 0:Type1:Non-Revertive Type2:Non-Revertive 1:Type1:Revertive Type2:Non-Revertive 2:Type1:Primary Type2:Primary 3:Type1:Sec…
1.3.6.1.4.1.4756.20.391.20.1.17ColumnprotectionWorkingPathread-onlycurrentFRM220- protection card Working Path: 0:Primary 1:Secondary
1.3.6.1.4.1.4756.20.391.20.1.18ColumnprotectionPrimarySignalread-onlycurrentFRM220- protection card Primary Signal: 0:Loss 1:Normal
1.3.6.1.4.1.4756.20.391.20.1.19ColumnprotectionSecondarySignalread-onlycurrentFRM220- protection card Secondary Signal: 0:Loss 1:Normal
1.3.6.1.4.1.4756.20.391.20.1.20ColumnprotectionPrimaryDetectLevelread-writecurrentFRM220- protection card Primary Detect Level: 0:-35dB 1:-33dB 2:-31dB 3:-29dB 4:-27dB 5:-25dB 6:-23dB 7:-21dB 8:-19dB 9:-17dB 10:-15dB 11:-13dB 12:-11dB 13:-9d…
1.3.6.1.4.1.4756.20.391.20.1.21ColumnprotectionPrimaryPowerSignread-onlycurrentFRM220- protection card Primary Power Sign: 0:Postive 1:Negativ
1.3.6.1.4.1.4756.20.391.20.1.22ColumnprotectionPrimaryPowerread-onlycurrentFRM220- protection card Primary Power
1.3.6.1.4.1.4756.20.391.20.1.23ColumnprotectionSecondaryDetectLevelread-writecurrentFRM220- protection card Secondary Detect Level: 0:-35dB 1:-33dB 2:-31dB 3:-29dB 4:-27dB 5:-25dB 6:-23dB 7:-21dB 8:-19dB 9:-17dB 10:-15dB 11:-13dB 12:-11dB 13:-…
1.3.6.1.4.1.4756.20.391.20.1.24ColumnprotectionSecondaryPowerSignread-onlycurrentFRM220- protection card Secondary Power Sign: 0:Positive 1:Negative
1.3.6.1.4.1.4756.20.391.20.1.25ColumnprotectionSecondaryPowerread-onlycurrentFRM220- protection card Secondary Power
1.3.6.1.4.1.4756.20.391.20.1.26ColumnprotectionChangeTimeread-writecurrentFRM220-protection card change time, only support OPS51 and OPS51M. 0:5sec 1:10sec 2:20sec 3:30sec 4:60sec 5:120sec 6:240sec 7:480sec 8:Not Support
1.3.6.1.4.1.4756.20.391.20.1.27ColumnprotectionTyperead-onlycurrentFRM220-protection card type 0:frm220-ops52 1:frm220-ops51 2:frm220-ops52p 3:frm220-ops51m
1.3.6.1.4.1.4756.20.391.20.1.28ColumnprotectionTransitionDelayTimeread-writecurrentLocal Frm220 protection Transition Delay Time (Unit is ms)
1.3.6.1.4.1.4756.20.400Nodefdse3LocalCards
1.3.6.1.4.1.4756.20.400.20TablefDS3E3LocalTablenot-accessiblecurrentA list of local FRM220-DS3/E3 card entries. The number of entries is fDS3/E3-No-L.
1.3.6.1.4.1.4756.20.400.20.1RowfDS3E3LocalEntrynot-accessiblecurrentAn entry containing management information applicable to a particular local FRM220-DS3/E3 card.
1.3.6.1.4.1.4756.20.400.20.1.1ColumnfDS3E3ChassisIndexLocalread-onlycurrentA unique value for each local card. It is the chassis location number.
1.3.6.1.4.1.4756.20.400.20.1.2ColumnfDS3E3SlotIndexLocalread-onlycurrentA unique value for each local card. It is the slot location number.
1.3.6.1.4.1.4756.20.400.20.1.3ColumnfDS3E3CardHWVerLocalread-onlycurrentLocal FRM220-DS3/E3 card hardware version x.xxx
1.3.6.1.4.1.4756.20.400.20.1.4ColumnfDS3E3CardFWVerLocalread-onlycurrentLocal FRM220-DS3/E3 card firmware version x.xxx
1.3.6.1.4.1.4756.20.400.20.1.5ColumnfDS3E3CardCPLDVerLocalread-onlycurrentLocal FRM220-DS3/E3 card CPLD version x.xxx
1.3.6.1.4.1.4756.20.400.20.1.6ColumnfDS3E3CardFPGAVerLocalread-onlycurrentLocal FRM220-DS3/E3 card FPGA version x.xxx
1.3.6.1.4.1.4756.20.400.20.1.7ColumnfDS3E3DeviceActiveLocalread-writecurrentDevie Active: 0:Disable 1:Enable
1.3.6.1.4.1.4756.20.400.20.1.8ColumnfDS3E3PortResetLocalread-writecurrentLocal FRM220-DS3/E3 card port reset: 0:OFF 1:ACTION
1.3.6.1.4.1.4756.20.400.20.1.9ColumnfDS3E3SetDefaultLocalread-writecurrentLocal FRM220-DS3/E3 card set to default: 0:OFF 1:ACTION
1.3.6.1.4.1.4756.20.400.20.1.10ColumnfDS3E3CoaxLinkLocalread-onlycurrentLocal FRM220-DS3/E3 card Coax link status: 0:OFF 1:ON
1.3.6.1.4.1.4756.20.400.20.1.11ColumnfDS3E3CoaxRxAISLocalread-onlycurrentLocal FRM220-DS3/E3 card Coax Rx AIS status: 0:OFF 1:ON
1.3.6.1.4.1.4756.20.400.20.1.12ColumnfDS3E3CoaxTrnasmitLocalread-onlycurrentLocal FRM220-DS3/E3 card Coax Transit status: 0:Normal 1:Failure
1.3.6.1.4.1.4756.20.400.20.1.13ColumnfDS3E3CoaxModeTypeLocalread-writecurrentLocal FRM220-DS3/E3 card Coax Mode Type: 0:DS3 1:STS-1 2:E3
1.3.6.1.4.1.4756.20.400.20.1.14ColumnfDS3E3CoaxTxAISLocalread-writecurrentLocal FRM220-DS3/E3 card Coax Tx AIS: 0:Disbale 1:Enable
1.3.6.1.4.1.4756.20.400.20.1.15ColumnfDS3E3Fx1LinkLocalread-onlycurrentLocal FRM220-DS3/E3 Fiber1 link status: 0:Down 1:Up
1.3.6.1.4.1.4756.20.400.20.1.16ColumnfDS3E3Fx1FEFLocalread-onlycurrentLocal FRM220-DS3/E3 Fiber1 EFE status: 0:OFF 1:ON
1.3.6.1.4.1.4756.20.400.20.1.17ColumnfDS3E3Fx1ALSLocalread-writecurrentLocal FRM220-DS3/E3 Fiber1 Auto Laser Shutdown: 0:Disable 1:Enable
1.3.6.1.4.1.4756.20.400.20.1.18ColumnfDS3E3Fx1DDLocalread-onlycurrentLocal FRM220-DS3/E3 card fiber Digital Diagnostic function: 0:No 1:Yes
1.3.6.1.4.1.4756.20.400.20.1.19ColumnfDS3E3Fx1DDVendorLocalread-onlycurrentLocal FRM220-DS3/E3 card fiber D/D information: Vendor name
1.3.6.1.4.1.4756.20.400.20.1.20ColumnfDS3E3Fx1DDPartNoLocalread-onlycurrentLocal FRM220-DS3/E3 card fiber D/D information: Vendor part number
1.3.6.1.4.1.4756.20.400.20.1.21ColumnfDS3E3Fx1DDFiberTypeLocalread-onlycurrentLocal FRM220-DS3/E3 card fiber D/D information: Fiber Type
1.3.6.1.4.1.4756.20.400.20.1.22ColumnfDS3E3Fx1DDWaveLenLocalread-onlycurrentLocal FRM220-DS3/E3 card fiber D/D information: Wave length
1.3.6.1.4.1.4756.20.400.20.1.23ColumnfDS3E3Fx1DDWaveLen2Localread-onlycurrentLocal FRM220-DS3/E3 card fiber D/D information: Wave length 2
1.3.6.1.4.1.4756.20.400.20.1.24ColumnfDS3E3Fx1DDLinkLenLocalread-onlycurrentLocal FRM220-DS3/E3 card fiber D/D information: Link length
1.3.6.1.4.1.4756.20.400.20.1.25ColumnfDS3E3Fx1DDLenUnitLocalread-onlycurrentLocal FRM220-DS3/E3 card fiber D/D information: Length Unit
1.3.6.1.4.1.4756.20.400.20.1.26ColumnfDS3E3Fx1DDStatusLocalread-onlycurrentLocal FRM220-DS3/E3 card fiber D/D information: Status Support
1.3.6.1.4.1.4756.20.400.20.1.27ColumnfDS3E3Fx1DDRxSensLocalread-onlycurrentLocal FRM220-DS3/E3 card fiber D/D information: Rx Sensitivity
1.3.6.1.4.1.4756.20.400.20.1.28ColumnfDS3E3Fx1DDTxPWRLocalread-onlycurrentLocal FRM220-DS3/E3 card fiber D/D information: Tx power
1.3.6.1.4.1.4756.20.400.20.1.29ColumnfDS3E3Fx1DDRxPWRLocalread-onlycurrentLocal FRM220-DS3/E3 card fiber D/D information: Rx power
1.3.6.1.4.1.4756.20.400.20.1.30ColumnfDS3E3Fx1DDTempLocalread-onlycurrentLocal FRM220-DS3/E3 card fiber D/D information: Temperature in degree C
1.3.6.1.4.1.4756.20.400.20.1.31ColumnfDS3E3Fx1DDPWRMarginLocalread-onlycurrentLocal FRM220-DS3/E3 card fiber D/D information: Power margin
1.3.6.1.4.1.4756.20.400.20.1.32ColumnfDS3E3LoopBackSelectLocalread-writecurrentLocal FRM220-DS3/E3 card LoopBack select side: 0:Fiber side 1:Coax side
1.3.6.1.4.1.4756.20.400.20.1.33ColumnfDS3E3LoopBackFunLocalread-writecurrentLocal FRM220-DS3/E3 card LoopBack function: 0:OFF 1:LLB 2:RLB 3:RRLB
1.3.6.1.4.1.4756.20.400.20.1.34ColumnfDS3E3ESCounterLocalread-onlycurrentLocal FRM220-DS3/E3 card Performance: ES Counter
1.3.6.1.4.1.4756.20.400.20.1.35ColumnfDS3E3CoaxESCounterLocalread-onlycurrentLocal FRM220-DS3/E3 card Performance: Coax ES Counter
1.3.6.1.4.1.4756.20.400.20.1.36ColumnfDS3E3FxESCounterLocalread-onlycurrentLocal FRM220-DS3/E3 card Performance: Fx ES Counter
1.3.6.1.4.1.4756.20.400.20.1.37ColumnfDS3E3ClearESCounterLocalread-writecurrentLocal FRM220-DS3/E3 card Clear ES Counter: 0:OFF 1:ACTION
1.3.6.1.4.1.4756.20.400.20.1.38ColumnfDS3E3FxBitCounterLocalread-onlycurrentLocal FRM220-DS3/E3 card Performance: Fx Bit Counter
1.3.6.1.4.1.4756.20.400.20.1.39ColumnfDS3E3ClearFxBitCounterLocalread-writecurrentLocal FRM220-DS3/E3 card Clear Fx Bit Counter: 0:OFF 1:ACTION
1.3.6.1.4.1.4756.20.400.20.1.40ColumnfDS3E3FxInsert1ErrorBitLocalread-writecurrentLocal FRM220-DS3/E3 card Fx Inser one error Bit: 0:Normal 1:Insert
1.3.6.1.4.1.4756.20.400.20.1.41ColumnfDS3E3CoaxBitCounterLocalread-onlycurrentLocal FRM220-DS3/E3 card Performance: Coax Bit Counter
1.3.6.1.4.1.4756.20.400.20.1.42ColumnfDS3E3ClearCoaxBitCounterLocalread-writecurrentLocal FRM220-DS3/E3 card Clear Coax Bit Counter: 0:OFF 1:ACTION
1.3.6.1.4.1.4756.20.400.20.1.43ColumnfDS3E3PRBSLocalread-writecurrentLocal FRM220-DS3/E3 card PRBS: 0:disable 1:Enable
1.3.6.1.4.1.4756.20.400.20.1.44ColumnfDS3E3CoaxInsert1ErrorBitLocalread-writecurrentLocal FRM220-DS3/E3 card Coax Insert One Error Bit: 0:Normal 1:Insert
1.3.6.1.4.1.4756.20.400.20.1.45ColumnfDS3E3systemstatusLocalread-onlycurrentLocal FRM220-DS3/E3 System Status: 0:OFF 1:On
1.3.6.1.4.1.4756.20.401Nodefdse3RemoteCards
1.3.6.1.4.1.4756.20.401.20TablefDS3E3RemoteTablenot-accessiblecurrentA list of Remote FRM220-DS3/E3 card entries. The number of entries is fDS3/E3-No-L.
1.3.6.1.4.1.4756.20.401.20.1RowfDS3E3RemoteEntrynot-accessiblecurrentAn entry containing management information applicable to a particular Remote FRM220-DS3/E3 card.
1.3.6.1.4.1.4756.20.401.20.1.1ColumnfDS3E3ChassisIndexRemoteread-onlycurrentA unique value for each Remote card. It is the chassis location number.
1.3.6.1.4.1.4756.20.401.20.1.2ColumnfDS3E3SlotIndexRemoteread-onlycurrentA unique value for each Remote card. It is the slot location number.
1.3.6.1.4.1.4756.20.401.20.1.3ColumnfDS3E3CardHWVerRemoteread-onlycurrentRemote FRM220-DS3/E3 card hardware version x.xxx
1.3.6.1.4.1.4756.20.401.20.1.4ColumnfDS3E3CardFWVerRemoteread-onlycurrentRemote FRM220-DS3/E3 card firmware version x.xxx
1.3.6.1.4.1.4756.20.401.20.1.5ColumnfDS3E3CardCPLDVerRemoteread-onlycurrentRemote FRM220-DS3/E3 card CPLD version x.xxx
1.3.6.1.4.1.4756.20.401.20.1.6ColumnfDS3E3CardFPGAVerRemoteread-onlycurrentRemote FRM220-DS3/E3 card FPGA version x.xxx
1.3.6.1.4.1.4756.20.401.20.1.7ColumnfDS3E3PortResetRemoteread-writecurrentRemote FRM220-DS3/E3 card port reset: 0:OFF 1:ACTION
1.3.6.1.4.1.4756.20.401.20.1.8ColumnfDS3E3SetDefaultRemoteread-writecurrentRemote FRM220-DS3/E3 card set to default: 0:OFF 1:ACTION
1.3.6.1.4.1.4756.20.401.20.1.9ColumnfDS3E3CoaxLinkRemoteread-onlycurrentRemote FRM220-DS3/E3 card Coax link status: 0:OFF 1:ON
1.3.6.1.4.1.4756.20.401.20.1.10ColumnfDS3E3CoaxRxAISRemoteread-onlycurrentRemote FRM220-DS3/E3 card Coax Rx AIS status: 0:OFF 1:ON
1.3.6.1.4.1.4756.20.401.20.1.11ColumnfDS3E3CoaxTrnasmitRemoteread-onlycurrentRemote FRM220-DS3/E3 card Coax Transit status: 0:Normal 1:Failure
1.3.6.1.4.1.4756.20.401.20.1.12ColumnfDS3E3CoaxModeTypeRemoteread-writecurrentRemote FRM220-DS3/E3 card Coax Mode Type: 0:DS3 1:STS-1 2:E3
1.3.6.1.4.1.4756.20.401.20.1.13ColumnfDS3E3CoaxTxAISRemoteread-writecurrentRemote FRM220-DS3/E3 card Coax Tx AIS: 0:Disbale 1:Enable
1.3.6.1.4.1.4756.20.401.20.1.14ColumnfDS3E3Fx1LinkRemoteread-onlycurrentRemote FRM220-DS3/E3 Fiber1 link status: 0:Down 1:Up
1.3.6.1.4.1.4756.20.401.20.1.15ColumnfDS3E3Fx1FEFRemoteread-onlycurrentRemote FRM220-DS3/E3 Fiber1 EFE status: 0:OFF 1:ON
1.3.6.1.4.1.4756.20.401.20.1.16ColumnfDS3E3Fx1ALSRemoteread-writecurrentRemote FRM220-DS3/E3 Fiber1 Auto Laser Shutdown: 0:Disable 1:Enable
1.3.6.1.4.1.4756.20.401.20.1.17ColumnfDS3E3Fx1DDRemoteread-onlycurrentRemote FRM220-DS3/E3 card fiber Digital Diagnostic function: 0:No 1:Yes
1.3.6.1.4.1.4756.20.401.20.1.18ColumnfDS3E3Fx1DDVendorRemoteread-onlycurrentRemote FRM220-DS3/E3 card fiber D/D information: Vendor name
1.3.6.1.4.1.4756.20.401.20.1.19ColumnfDS3E3Fx1DDPartNoRemoteread-onlycurrentRemote FRM220-DS3/E3 card fiber D/D information: Vendor part number
1.3.6.1.4.1.4756.20.401.20.1.20ColumnfDS3E3Fx1DDFiberTypeRemoteread-onlycurrentRemote FRM220-DS3/E3 card fiber D/D information: Fiber Type
1.3.6.1.4.1.4756.20.401.20.1.21ColumnfDS3E3Fx1DDWaveLenRemoteread-onlycurrentRemote FRM220-DS3/E3 card fiber D/D information: Wave length
1.3.6.1.4.1.4756.20.401.20.1.22ColumnfDS3E3Fx1DDWaveLen2Remoteread-onlycurrentRemote FRM220-DS3/E3 card fiber D/D information: Wave length 2
1.3.6.1.4.1.4756.20.401.20.1.23ColumnfDS3E3Fx1DDLinkLenRemoteread-onlycurrentRemote FRM220-DS3/E3 card fiber D/D information: Link length
1.3.6.1.4.1.4756.20.401.20.1.24ColumnfDS3E3Fx1DDLenUnitRemoteread-onlycurrentRemote FRM220-DS3/E3 card fiber D/D information: Length Unit
1.3.6.1.4.1.4756.20.401.20.1.25ColumnfDS3E3Fx1DDStatusRemoteread-onlycurrentRemote FRM220-DS3/E3 card fiber D/D information: Status Support
1.3.6.1.4.1.4756.20.401.20.1.26ColumnfDS3E3Fx1DDRxSensRemoteread-onlycurrentRemote FRM220-DS3/E3 card fiber D/D information: Rx Sensitivity
1.3.6.1.4.1.4756.20.401.20.1.27ColumnfDS3E3Fx1DDTxPWRRemoteread-onlycurrentRemote FRM220-DS3/E3 card fiber D/D information: Tx power
1.3.6.1.4.1.4756.20.401.20.1.28ColumnfDS3E3Fx1DDRxPWRRemoteread-onlycurrentRemote FRM220-DS3/E3 card fiber D/D information: Rx power
1.3.6.1.4.1.4756.20.401.20.1.29ColumnfDS3E3Fx1DDTempRemoteread-onlycurrentRemote FRM220-DS3/E3 card fiber D/D information: Temperature in degree C
1.3.6.1.4.1.4756.20.401.20.1.30ColumnfDS3E3Fx1DDPWRMarginRemoteread-onlycurrentRemote FRM220-DS3/E3 card fiber D/D information: Power margin
1.3.6.1.4.1.4756.20.401.20.1.31ColumnfDS3E3LoopBackFunRemoteread-writecurrentRemote FRM220-DS3/E3 card LoopBack function(Coax Only): 0:OFF 1:LLB 2:RLB
1.3.6.1.4.1.4756.20.401.20.1.32ColumnfDS3E3ESCounterRemoteread-onlycurrentRemote FRM220-DS3/E3 card Performance: ES Counter
1.3.6.1.4.1.4756.20.401.20.1.33ColumnfDS3E3CoaxESCounterRemoteread-onlycurrentRemote FRM220-DS3/E3 card Performance: Coax ES Counter
1.3.6.1.4.1.4756.20.401.20.1.34ColumnfDS3E3FxESCounterRemoteread-onlycurrentRemote FRM220-DS3/E3 card Performance: Fx ES Counter
1.3.6.1.4.1.4756.20.401.20.1.35ColumnfDS3E3ClearESCounterRemoteread-writecurrentRemote FRM220-DS3/E3 card Clear ES Counter: 0:OFF 1:ACTION
1.3.6.1.4.1.4756.20.401.20.1.36ColumnfDS3E3FxBitCounterRemoteread-onlycurrentRemote FRM220-DS3/E3 card Performance: Fx Bit Counter
1.3.6.1.4.1.4756.20.401.20.1.37ColumnfDS3E3ClearFxBitCounterRemoteread-writecurrentRemote FRM220-DS3/E3 card Clear Fx Bit Counter: 0:OFF 1:ACTION
1.3.6.1.4.1.4756.20.401.20.1.38ColumnfDS3E3FxInsert1ErrorBitRemoteread-writecurrentRemote FRM220-DS3/E3 card Fx Insert One Error Bit: 0:Normal 1:Insert
1.3.6.1.4.1.4756.20.401.20.1.39ColumnfDS3E3CoaxBitCounterRemoteread-onlycurrentRemote FRM220-DS3/E3 card Performance: Coax Bit Counter
1.3.6.1.4.1.4756.20.401.20.1.40ColumnfDS3E3ClearCoaxBitCounterRemoteread-writecurrentRemote FRM220-DS3/E3 card Clear Coax Bit Counter: 0:OFF 1:ACTION
1.3.6.1.4.1.4756.20.401.20.1.41ColumnfDS3E3PRBSRemoteread-writecurrentRemote FRM220-DS3/E3 card PRBS: 0:Disable 1:Enable
1.3.6.1.4.1.4756.20.401.20.1.42ColumnfDS3E3CoaxInsert1ErrorBitRemoteread-writecurrentRemote FRM220-DS3/E3 card Coax Insert One Error Bit: 0:Normal 1:Insert
1.3.6.1.4.1.4756.20.401.20.1.43ColumnfDS3E3systemstatusRemoteread-onlycurrentRemote FRM220-DS3/E3 System Status: 0:OFF 1:ON
1.3.6.1.4.1.4756.20.410Nodef1000EASX1LocalCards
1.3.6.1.4.1.4756.20.410.40Tablef1000EASX1LocalTablenot-accessiblecurrentA list of local 1000EAS/X card entries.
1.3.6.1.4.1.4756.20.410.40.1Rowf1000EASX1LocalEntrynot-accessiblecurrentAn entry containing management information applicable to a particular local f1000EASX card.
1.3.6.1.4.1.4756.20.410.40.1.1Columnf1000EASX1ChassisIndexLocalread-onlycurrentA unique value for each chassis ID. For CH20, it is the chassis ID. For CH08, it is always 0.
1.3.6.1.4.1.4756.20.410.40.1.2Columnf1000EASX1SlotIndexLocalread-onlycurrentA unique value for each local card. It is the slot location number.
1.3.6.1.4.1.4756.20.410.40.1.3Columnf1000EASX1CardHWVerLocalread-onlycurrentLocal device card hardware version x.xxx
1.3.6.1.4.1.4756.20.410.40.1.4Columnf1000EASX1CardFWVerLocalread-onlycurrentLocal device card firmware version x.xxx
1.3.6.1.4.1.4756.20.410.40.1.5Columnf1000EASX1CardCPLDVerLocalread-onlycurrentLocal device card CPLD version x.xxx
1.3.6.1.4.1.4756.20.410.40.1.6Columnf1000EASX1CardFPGAVerLocalread-onlycurrentLocal device card FPGA version x.xxx
1.3.6.1.4.1.4756.20.410.40.1.7Columnf1000EASX1ModelLocalread-onlycurrentLocal 1000EAS/X-1 Serial Type
1.3.6.1.4.1.4756.20.410.40.1.8Columnf1000EASX1FiberLinkLocalread-onlycurrentLocal device card fiber port link status: 0:Down 1:Up
1.3.6.1.4.1.4756.20.410.40.1.9Columnf1000EASX1FiberOAMLoopedLocalread-onlycurrentLocal device card fiber port OAM looped: 0:Off 1:on
1.3.6.1.4.1.4756.20.410.40.1.10Columnf1000EASX1FiberLBTestLocalread-writecurrentForce remote device card to do fiber port LoopBack testing: 0:Off 1:Action
1.3.6.1.4.1.4756.20.410.40.1.11Columnf1000EASX1FiberOAMRLBStatusLocalread-onlycurrentRemote device card fiber port LoopBack testing status: 0:Off 1:Ok 2:Fail
1.3.6.1.4.1.4756.20.410.40.1.12Columnf1000EASX1FiberRemoPwrAbLocalread-onlycurrentLocal device card fiber port 1 Remote Power status: 0:Abnormal 1:OK 2:None
1.3.6.1.4.1.4756.20.410.40.1.13Columnf1000EASX1FiberFEFLocalread-onlycurrentLocal device card fiber port FEF status: 0:Off 1:Detected
1.3.6.1.4.1.4756.20.410.40.1.14Columnf1000EASX1FiberIngressRateLocalread-writecurrentLocal device card fiber Ingress Rate Limit: 0 = Unlimit input format: 64k(K),100m(M),100 If doesn't input the unit, the default was Mega. Limite Rate : 64K ~ 9…
1.3.6.1.4.1.4756.20.410.40.1.15Columnf1000EASX1FiberEgressRateLocalread-writecurrentLocal device card fiber Egress Rate Limit: 0 = Unlimit input format: 64k(K),100m(M),100 If doesn't input the unit, the default was Mega. Limite Rate : 64K ~ 99…
1.3.6.1.4.1.4756.20.410.40.1.16Columnf1000EASX1UtpLinkLocalread-onlycurrentLocal device card UTP port link status: 0:Down 1:Up
1.3.6.1.4.1.4756.20.410.40.1.17Columnf1000EASX1UtpNegoLocalread-writecurrentLocal device card UTP port negotiation status: 0:Manual 1:Auto
1.3.6.1.4.1.4756.20.410.40.1.18Columnf1000EASX1UtpSpeedLocalread-writecurrentLocal device card UTP port speed setting: 0:10 Base-T 1:100 Base-TX 2:1000 Base-TX
1.3.6.1.4.1.4756.20.410.40.1.19Columnf1000EASX1UtpDuplexLocalread-writecurrentLocal device card UTP port duplex setting: 0:Half duplex mode 1:Full duplex mode
1.3.6.1.4.1.4756.20.410.40.1.20Columnf1000EASX1UtpSpeedStatusLocalread-onlycurrentLocal device card UTP port speed status: 0:10 Base-T 1:100 Base-TX 2:1000 Base-TX
1.3.6.1.4.1.4756.20.410.40.1.21Columnf1000EASX1UtpDuplexStatusLocalread-onlycurrentLocal device card UTP port duplex status: 0:Half duplex mode 1:Full duplex mode
1.3.6.1.4.1.4756.20.410.40.1.22Columnf1000EASX1UtpIngressRateLocalread-writecurrentLocal device card utp Ingress Rate Limit: 0 = Unlimit input format: 64k(K),100m(M),100 If doesn't input the unit, the default was Mega. Limite Rate : 64K ~ 990M
1.3.6.1.4.1.4756.20.410.40.1.23Columnf1000EASX1UtpEgressRateLocalread-writecurrentLocal device card utp Egress Rate Limit: 0 = Unlimit input format: 64k(K),100m(M),100 If doesn't input the unit, the default was Mega. Limite Rate : 64K ~ 990M
1.3.6.1.4.1.4756.20.410.40.1.24Columnf1000EASX1DeviceActiveLocalread-writecurrentLocal device card active mode: (It is read-only in remote device.) 0:Disable 1:Enable
1.3.6.1.4.1.4756.20.410.40.1.25Columnf1000EASX1DeviceResetLocalread-writecurrentForce local device card to reset mode: 0:Off 1:Action
1.3.6.1.4.1.4756.20.410.40.1.26Columnf1000EASX1FiberActiveLocalread-writecurrentLocal device fiber port active mode: 0:Disable 1:Enable
1.3.6.1.4.1.4756.20.410.40.1.27Columnf1000EASX1UtpActiveLocalread-writecurrentLocal device UTP port active mode: 0:Disable 1:Enable
1.3.6.1.4.1.4756.20.410.40.1.28Columnf1000EASX1OamChModeLocalread-writecurrentLocal device OAM Channel mode: 0:Disable 1:passive 2:Active
1.3.6.1.4.1.4756.20.410.40.1.29Columnf1000EASX1OamMaxPDUsLocalread-writecurrentLocal device OAM max OAMPDU size: 60-1518 Octets
1.3.6.1.4.1.4756.20.410.40.1.30Columnf1000EASX1FiberAlsLocalread-writecurrentLocal device card port Auto Laser Shutdown mode: 0:Disable 1:Enable
1.3.6.1.4.1.4756.20.410.40.1.31Columnf1000EASX1PauseFrameLocalread-writecurrentLocal device card pause frame mode: 0:Disable 1:Enable
1.3.6.1.4.1.4756.20.410.40.1.32Columnf1000EASX1SendFHRtoALocalread-writecurrentLocal device card port send Fiber Hardware Reset to remote: 0:No action 1:Action
1.3.6.1.4.1.4756.20.410.40.1.33Columnf1000EASX1FiberLLFDepPortLocalread-writecurrentLocal device card port Link Loss Forwarding depends on port 3 Ethernet Rx link: 0:don't care 1:selected
1.3.6.1.4.1.4756.20.410.40.1.34Columnf1000EASX1UtpLLFDepPortLocalread-writecurrentLocal device card port Link Loss Forwarding depends on port Fiber Rx link: 0:don't care 1:selected
1.3.6.1.4.1.4756.20.410.40.1.35Columnf1000EASX1AdvanceFunsLocalread-writecurrentLocal device card Switch functions mode: 0:Normal 5:Static 802.1Q VLAN 6:Spanning Tree Protocol 7:802.1Q VLAN Trunk 9:Q in Q VLAN 11:Spanning Tree Protocol and…
1.3.6.1.4.1.4756.20.410.40.1.36Columnf1000EASX1FiberInfoROM1Localread-onlycurrentLocal device card port INFORemoteOM information 1 valid: 0:Invalid 1:Valid
1.3.6.1.4.1.4756.20.410.40.1.37Columnf1000EASX1FiberInfoROM2Localread-onlycurrentLocal device card port INFORemoteOM information 2 valid: 0:Invalid 1:Valid(replacing D/D function
1.3.6.1.4.1.4756.20.410.40.1.38Columnf1000EASX1FiberInfoSN1Localread-onlycurrentLocal device card port 1 NFORemoteOM S/N 1
1.3.6.1.4.1.4756.20.410.40.1.39Columnf1000EASX1FiberInfoSN2Localread-onlycurrentLocal device card port 1 INFORemoteOM S/N 2
1.3.6.1.4.1.4756.20.410.40.1.40Columnf1000EASX1FiberDDLocalread-onlycurrentLocal device card fiber port Digital Diagnostic function: 0:No 1:Yes
1.3.6.1.4.1.4756.20.410.40.1.41Columnf1000EASX1FiberDDVendorLocalread-onlycurrentLocal device card fiber port D/D information: Vendor name
1.3.6.1.4.1.4756.20.410.40.1.42Columnf1000EASX1FiberDDPartNoLocalread-onlycurrentLocal device card fiber port D/D information: Vendor part number
1.3.6.1.4.1.4756.20.410.40.1.43Columnf1000EASX1FiberDDVendorSNLocalread-onlycurrentLocal device card fiber port D/D information: Vendor Serial Number
1.3.6.1.4.1.4756.20.410.40.1.44Columnf1000EASX1FiberDDFiberTypeLocalread-onlycurrentLocal device card fiber port D/D information: Fiber Type
1.3.6.1.4.1.4756.20.410.40.1.45Columnf1000EASX1FiberDDWaveLenLocalread-onlycurrentLocal device card fiber port D/D information: Wave length
1.3.6.1.4.1.4756.20.410.40.1.46Columnf1000EASX1FiberDDWaveLen2Localread-onlycurrentLocal device card fiber port D/D information: Wave length 2
1.3.6.1.4.1.4756.20.410.40.1.47Columnf1000EASX1FiberDDLinkLenLocalread-onlycurrentLocal device card fiber port D/D information: Link length
1.3.6.1.4.1.4756.20.410.40.1.48Columnf1000EASX1FiberDDLenUnitLocalread-onlycurrentLocal device card fiber port D/D information: Length Unit
1.3.6.1.4.1.4756.20.410.40.1.49Columnf1000EASX1FiberDDStatusLocalread-onlycurrentLocal device card fiber port D/D information: Status Support
1.3.6.1.4.1.4756.20.410.40.1.50Columnf1000EASX1FiberDDRxSensLocalread-onlycurrentLocal device card fiber port D/D information: Rx Sensitivity
1.3.6.1.4.1.4756.20.410.40.1.51Columnf1000EASX1FiberDDTxPWRLocalread-onlycurrentLocal device card fiber port D/D information: Tx power
1.3.6.1.4.1.4756.20.410.40.1.52Columnf1000EASX1FiberDDRxPWRLocalread-onlycurrentLocal device card fiber port D/D information: Rx power
1.3.6.1.4.1.4756.20.410.40.1.53Columnf1000EASX1FiberDDTempLocalread-onlycurrentLocal device card fiber port D/D information: Temperature in degree C
1.3.6.1.4.1.4756.20.410.40.1.54Columnf1000EASX1FiberDDPWRMarginLocalread-onlycurrentLocal device card fiber port D/D information: Power margin
1.3.6.1.4.1.4756.20.410.40.1.55Columnf1000EASX1FiberDDPWRLossLocalread-onlycurrentLocal device card fiber port D/D information: Power loss
1.3.6.1.4.1.4756.20.410.40.1.56Columnf1000EASX1ClrRMONCntsLocalread-writecurrentClear local device card RMON IN/OUT counters: 0:No action 1:Action
1.3.6.1.4.1.4756.20.410.40.1.57Columnf1000EASX1FiberRMONInLocalread-onlycurrentLocal device card port RMON IN counter.
1.3.6.1.4.1.4756.20.410.40.1.58Columnf1000EASX1FiberRMONOutLocalread-onlycurrentLocal device card port RMON OUT counter.
1.3.6.1.4.1.4756.20.410.40.1.59Columnf1000EASX1UtpRMONInLocalread-onlycurrentLocal device card port RMON IN counter.
1.3.6.1.4.1.4756.20.410.40.1.60Columnf1000EASX1UtpRMONOutLocalread-onlycurrentLocal device card port RMON OUT counter.
1.3.6.1.4.1.4756.20.410.40.1.61Columnf1000EASX1ClrOAMCntsLocalread-writecurrentClear local device card OAM counters: 0:No action 1:Action
1.3.6.1.4.1.4756.20.410.40.1.62Columnf1000EASX1IpModeLocalread-writecurrentOn Rack Ip Mode: 0:Enable 1:Disable
1.3.6.1.4.1.4756.20.410.40.1.63Columnf1000EASX1OamChTxLocalread-onlycurrentLocal device OAM Channel TX OAMPDU frame count
1.3.6.1.4.1.4756.20.410.40.1.64Columnf1000EASX1OamChRxLocalread-onlycurrentLocal device OAM Channel RX OAMPDU frame count
1.3.6.1.4.1.4756.20.410.40.1.65Columnf1000EASX1OamInfoChTxLocalread-onlycurrentLocal device OAM Channel TX Information OAMPDU frame count
1.3.6.1.4.1.4756.20.410.40.1.66Columnf1000EASX1OamInfoChRxLocalread-onlycurrentLocal device OAM Channel RX Information OAMPDU frame count
1.3.6.1.4.1.4756.20.410.40.1.67Columnf1000EASX1OamEventChTxLocalread-onlycurrentLocal device OAM Channel TX Event OAMPDU frame count
1.3.6.1.4.1.4756.20.410.40.1.68Columnf1000EASX1OamUniEvtChRxLocalread-onlycurrentLocal device OAM Channel RX Unique Event OAMPDU frame count
1.3.6.1.4.1.4756.20.410.40.1.69Columnf1000EASX1OamDupEvtChRxLocalread-onlycurrentLocal device OAM Channel RX Duplicate Event OAMPDU frame count
1.3.6.1.4.1.4756.20.410.40.1.70Columnf1000EASX1OamLbChTxLocalread-onlycurrentLocal device OAM Channel TX Loopback Control OAMPDU frame count
1.3.6.1.4.1.4756.20.410.40.1.71Columnf1000EASX1OamLbChRxLocalread-onlycurrentLocal device OAM Channel RX Loopback Control OAMPDU frame count
1.3.6.1.4.1.4756.20.410.40.1.72Columnf1000EASX1OamVarReqChTxLocalread-onlycurrentLocal device OAM Channel TX Variable Request OAMPDU frame count
1.3.6.1.4.1.4756.20.410.40.1.73Columnf1000EASX1OamVarReqChRxLocalread-onlycurrentLocal device OAM Channel RX Variable Request OAMPDU frame count
1.3.6.1.4.1.4756.20.410.40.1.74Columnf1000EASX1OamVarRspChTxLocalread-onlycurrentLocal device OAM Channel TX Variable Response OAMPDU frame count
1.3.6.1.4.1.4756.20.410.40.1.75Columnf1000EASX1OamVarRspChRxLocalread-onlycurrentLocal device OAM Channel RX Variable Response OAMPDU frame count
1.3.6.1.4.1.4756.20.410.40.1.76Columnf1000EASX1OamOuiChTxLocalread-onlycurrentLocal device OAM Channel TX OUI OAMPDU frame count
1.3.6.1.4.1.4756.20.410.40.1.77Columnf1000EASX1OamOuiChRxLocalread-onlycurrentLocal device OAM Channel RX OUI OAMPDU frame count
1.3.6.1.4.1.4756.20.410.40.1.78Columnf1000EASX1OamUnknowChRxLocalread-onlycurrentLocal device OAM Channel RX Unsupported OAMPDU frame count
1.3.6.1.4.1.4756.20.410.40.1.79Columnf1000EASX1FiberSpeedLocalread-writecurrentLocal device Fiber speed : 0:1000 1:100
1.3.6.1.4.1.4756.20.410.40.1.80Columnf1000EASX1MacLearningLocalread-writecurrentLocal device Mac learning : 0:Disable 1:Enable
1.3.6.1.4.1.4756.20.410.40.1.81Columnf1000EASX1Port1VIDLocalread-writecurrentLocal device Port 1 VID :
1.3.6.1.4.1.4756.20.410.40.1.82Columnf1000EASX1Port2VIDLocalread-writecurrentLocal device Port 2 VID :
1.3.6.1.4.1.4756.20.410.40.1.83Columnf1000EASX1Port1QinQLocalread-writecurrentLocal device Port 1 Q in Q Support : 1:Disable 2:Enable
1.3.6.1.4.1.4756.20.410.40.1.84Columnf1000EASX1Port2QinQLocalread-writecurrentLocal device Port 2 Q in Q Support : 1:Disable 2:Enable
1.3.6.1.4.1.4756.20.410.40.1.85Columnf1000EASX1VID1Localread-writecurrentLocal device VID 1:
1.3.6.1.4.1.4756.20.410.40.1.86Columnf1000EASX1VID2Localread-writecurrentLocal device VID 2:
1.3.6.1.4.1.4756.20.410.40.1.87Columnf1000EASX1VID3Localread-writecurrentLocal device VID 3:
1.3.6.1.4.1.4756.20.410.40.1.88Columnf1000EASX1VID4Localread-writecurrentLocal device VID 4:
1.3.6.1.4.1.4756.20.410.40.1.89Columnf1000EASX1VID5Localread-writecurrentLocal device VID 5:
1.3.6.1.4.1.4756.20.410.40.1.90Columnf1000EASX1VID6Localread-writecurrentLocal device VID 6:
1.3.6.1.4.1.4756.20.410.40.1.91Columnf1000EASX1VID7Localread-writecurrentLocal device VID 7:
1.3.6.1.4.1.4756.20.410.40.1.92Columnf1000EASX1VID8Localread-writecurrentLocal device VID 8:
1.3.6.1.4.1.4756.20.410.40.1.93Columnf1000EASX1VID9Localread-writecurrentLocal device VID 9:
1.3.6.1.4.1.4756.20.410.40.1.94Columnf1000EASX1VID10Localread-writecurrentLocal device VID 10:
1.3.6.1.4.1.4756.20.410.40.1.95Columnf1000EASX1VID11Localread-writecurrentLocal device VID 11:
1.3.6.1.4.1.4756.20.410.40.1.96Columnf1000EASX1VID12Localread-writecurrentLocal device VID 12:
1.3.6.1.4.1.4756.20.410.40.1.97Columnf1000EASX1VID13Localread-writecurrentLocal device VID 13:
1.3.6.1.4.1.4756.20.410.40.1.98Columnf1000EASX1VID14Localread-writecurrentLocal device VID 14:
1.3.6.1.4.1.4756.20.410.40.1.99Columnf1000EASX1VID15Localread-writecurrentLocal device VID 15:
1.3.6.1.4.1.4756.20.410.40.1.100Columnf1000EASX1VID16Localread-writecurrentLocal device VID 16:
1.3.6.1.4.1.4756.20.410.40.1.101Columnf1000EASX1Port1Member1Localread-writecurrentLocal device card port 1 member: 0:Unmodify 1:Untagged 2:Tagged 3:Nonmember
1.3.6.1.4.1.4756.20.410.40.1.102Columnf1000EASX1Port1Member2Localread-writecurrentLocal device card port 1 member 2: 0:Unmodify 1:Untagged 2:Tagged 3:Nonmember
1.3.6.1.4.1.4756.20.410.40.1.103Columnf1000EASX1Port1Member3Localread-writecurrentLocal device card port 1 member 3: 0:Unmodify 1:Untagged 2:Tagged 3:Nonmember
1.3.6.1.4.1.4756.20.410.40.1.104Columnf1000EASX1Port1Member4Localread-writecurrentLocal device card port 1 member 4: 0:Unmodify 1:Untagged 2:Tagged 3:Nonmember
1.3.6.1.4.1.4756.20.410.40.1.105Columnf1000EASX1Port1Member5Localread-writecurrentLocal device card port 1 member 5: 0:Unmodify 1:Untagged 2:Tagged 3:Nonmember
1.3.6.1.4.1.4756.20.410.40.1.106Columnf1000EASX1Port1Member6Localread-writecurrentLocal device card port 1 member 6: 0:Unmodify 1:Untagged 2:Tagged 3:Nonmember
1.3.6.1.4.1.4756.20.410.40.1.107Columnf1000EASX1Port1Member7Localread-writecurrentLocal device card port 1 member 7: 0:Unmodify 1:Untagged 2:Tagged 3:Nonmember
1.3.6.1.4.1.4756.20.410.40.1.108Columnf1000EASX1Port1Member8Localread-writecurrentLocal device card port 1 member 8: 0:Unmodify 1:Untagged 2:Tagged 3:Nonmember
1.3.6.1.4.1.4756.20.410.40.1.109Columnf1000EASX1Port1Member9Localread-writecurrentLocal device card port 1 member 9: 0:Unmodify 1:Untagged 2:Tagged 3:Nonmember
1.3.6.1.4.1.4756.20.410.40.1.110Columnf1000EASX1Port1Member10Localread-writecurrentLocal device card port 1 member 10: 0:Unmodify 1:Untagged 2:Tagged 3:Nonmember
1.3.6.1.4.1.4756.20.410.40.1.111Columnf1000EASX1Port1Member11Localread-writecurrentLocal device card port 1 member 11: 0:Unmodify 1:Untagged 2:Tagged 3:Nonmember
1.3.6.1.4.1.4756.20.410.40.1.112Columnf1000EASX1Port1Member12Localread-writecurrentLocal device card port 1 member 12: 0:Unmodify 1:Untagged 2:Tagged 3:Nonmember
1.3.6.1.4.1.4756.20.410.40.1.113Columnf1000EASX1Port1Member13Localread-writecurrentLocal device card port 1 member 13: 0:Unmodify 1:Untagged 2:Tagged 3:Nonmember
1.3.6.1.4.1.4756.20.410.40.1.114Columnf1000EASX1Port1Member14Localread-writecurrentLocal device card port 1 member 14: 0:Unmodify 1:Untagged 2:Tagged 3:Nonmember
1.3.6.1.4.1.4756.20.410.40.1.115Columnf1000EASX1Port1Member15Localread-writecurrentLocal device card port 1 member 15: 0:Unmodify 1:Untagged 2:Tagged 3:Nonmember
1.3.6.1.4.1.4756.20.410.40.1.116Columnf1000EASX1Port1Member16Localread-writecurrentLocal device card port 1 member 16: 0:Unmodify 1:Untagged 2:Tagged 3:Nonmember
1.3.6.1.4.1.4756.20.410.40.1.117Columnf1000EASX1Port2Member1Localread-writecurrentLocal device card port 2 member: 0:Unmodify 1:Untagged 2:Tagged 3:Nonmember
1.3.6.1.4.1.4756.20.410.40.1.118Columnf1000EASX1Port2Member2Localread-writecurrentLocal device card port 2 member 2: 0:Unmodify 1:Untagged 2:Tagged 3:Nonmember
1.3.6.1.4.1.4756.20.410.40.1.119Columnf1000EASX1Port2Member3Localread-writecurrentLocal device card port 2 member 3: 0:Unmodify 1:Untagged 2:Tagged 3:Nonmember
1.3.6.1.4.1.4756.20.410.40.1.120Columnf1000EASX1Port2Member4Localread-writecurrentLocal device card port 2 member 4: 0:Unmodify 1:Untagged 2:Tagged 3:Nonmember
1.3.6.1.4.1.4756.20.410.40.1.121Columnf1000EASX1Port2Member5Localread-writecurrentLocal device card port 2 member 5: 0:Unmodify 1:Untagged 2:Tagged 3:Nonmember
1.3.6.1.4.1.4756.20.410.40.1.122Columnf1000EASX1Port2Member6Localread-writecurrentLocal device card port 2 member 6: 0:Unmodify 1:Untagged 2:Tagged 3:Nonmember
1.3.6.1.4.1.4756.20.410.40.1.123Columnf1000EASX1Port2Member7Localread-writecurrentLocal device card port 2 member 7: 0:Unmodify 1:Untagged 2:Tagged 3:Nonmember
1.3.6.1.4.1.4756.20.410.40.1.124Columnf1000EASX1Port2Member8Localread-writecurrentLocal device card port 2 member 8: 0:Unmodify 1:Untagged 2:Tagged 3:Nonmember
1.3.6.1.4.1.4756.20.410.40.1.125Columnf1000EASX1Port2Member9Localread-writecurrentLocal device card port 2 member 9: 0:Unmodify 1:Untagged 2:Tagged 3:Nonmember
1.3.6.1.4.1.4756.20.410.40.1.126Columnf1000EASX1Port2Member10Localread-writecurrentLocal device card port 2 member 10: 0:Unmodify 1:Untagged 2:Tagged 3:Nonmember
1.3.6.1.4.1.4756.20.410.40.1.127Columnf1000EASX1Port2Member11Localread-writecurrentLocal device card port 2 member 11: 0:Unmodify 1:Untagged 2:Tagged 3:Nonmember
1.3.6.1.4.1.4756.20.410.40.1.128Columnf1000EASX1Port2Member12Localread-writecurrentLocal device card port 2 member 12: 0:Unmodify 1:Untagged 2:Tagged 3:Nonmember
1.3.6.1.4.1.4756.20.410.40.1.129Columnf1000EASX1Port2Member13Localread-writecurrentLocal device card port 2 member 13: 0:Unmodify 1:Untagged 2:Tagged 3:Nonmember
1.3.6.1.4.1.4756.20.410.40.1.130Columnf1000EASX1Port2Member14Localread-writecurrentLocal device card port 2 member 14: 0:Unmodify 1:Untagged 2:Tagged 3:Nonmember
1.3.6.1.4.1.4756.20.410.40.1.131Columnf1000EASX1Port2Member15Localread-writecurrentLocal device card port 2 member 15: 0:Unmodify 1:Untagged 2:Tagged 3:Nonmember
1.3.6.1.4.1.4756.20.410.40.1.132Columnf1000EASX1Port2Member16Localread-writecurrentLocal device card port 2 member 16: 0:Unmodify 1:Untagged 2:Tagged 3:Nonmember
1.3.6.1.4.1.4756.20.410.40.1.133Columnf1000EASX1IpAddressLocalread-writecurrentLocal device IP address
1.3.6.1.4.1.4756.20.410.40.1.134Columnf1000EASX1NetMaskLocalread-writecurrentLocal device Netmask
1.3.6.1.4.1.4756.20.410.40.1.135Columnf1000EASX1GateWayLocalread-writecurrentLocal device Gateway
1.3.6.1.4.1.4756.20.410.40.1.136Columnf1000EASX1SetDefaultLocalread-writecurrentLocal device set to default
1.3.6.1.4.1.4756.20.410.40.1.137Columnf1000EASX1ManagementVIDLocalread-writecurrentLocal device Management VID :
1.3.6.1.4.1.4756.20.410.40.1.138Columnf1000EASX1TagTypeLocalread-writecurrentLocal device Tag Type (HEX) :
1.3.6.1.4.1.4756.20.410.40.1.139Columnf1000EASX1FxLinkAlarmLocalread-writecurrentLocal device fiber link alarm 0:Disable 1:Enable
1.3.6.1.4.1.4756.20.410.40.1.140Columnf1000EASX1UtpLinkAlarmLocalread-writecurrentLocal device utp link alarm 0:Disable 1:Enable
1.3.6.1.4.1.4756.20.410.40.1.141Columnf1000EASX1PingStatusLocalread-onlycurrentLocal device icmp ping status Show Ping Status 0: Normal 1: Not Ready 2: 5 packets transmitted, 5 received, 0 packet loss. (Ping OK) 3: 5 packets transmitted, …
1.3.6.1.4.1.4756.20.410.40.1.142Columnf1000EASX1PingIpAddressLocalread-writecurrentLocal device ping IP address
1.3.6.1.4.1.4756.20.410.40.1.143Columnf1000EASX1PingStartLocalread-writecurrentLocal device ping start 0:Off 1:Action
1.3.6.1.4.1.4756.20.410.40.1.144Columnf1000EASX1RemoteTLPTLocalread-writecurrentLocal device Remote TLPT mode : 0:Disalbe 1:Remote
1.3.6.1.4.1.4756.20.420Nodef1000EASX1RemoteACards
1.3.6.1.4.1.4756.20.420.40Tablef1000EASX1RemoteATablenot-accessiblecurrentA list of RemoteA 1000EAS/X-1 card entries.
1.3.6.1.4.1.4756.20.420.40.1Rowf1000EASX1RemoteAEntrynot-accessiblecurrentAn entry containing management information applicable to a particular RemoteA f1000EASX-1 card.
1.3.6.1.4.1.4756.20.420.40.1.1Columnf1000EASX1ChassisIndexRemoteAread-onlycurrentA unique value for each chassis ID. For CH20, it is the chassis ID. For CH08, it is always 0.
1.3.6.1.4.1.4756.20.420.40.1.2Columnf1000EASX1SlotIndexRemoteAread-onlycurrentA unique value for each RemoteA card. It is the slot location number.
1.3.6.1.4.1.4756.20.420.40.1.3Columnf1000EASX1CardHWVerRemoteAread-onlycurrentRemoteA device card hardware version x.xxx
1.3.6.1.4.1.4756.20.420.40.1.4Columnf1000EASX1CardFWVerRemoteAread-onlycurrentRemoteA device card firmware version x.xxx
1.3.6.1.4.1.4756.20.420.40.1.5Columnf1000EASX1CardCPLDVerRemoteAread-onlycurrentRemoteA device card CPLD version x.xxx
1.3.6.1.4.1.4756.20.420.40.1.6Columnf1000EASX1CardFPGAVerRemoteAread-onlycurrentRemoteA device card FPGA version x.xxx
1.3.6.1.4.1.4756.20.420.40.1.7Columnf1000EASX1ModelRemoteAread-onlycurrentRemoteA 1000EAS/X-1 Serial Type
1.3.6.1.4.1.4756.20.420.40.1.8Columnf1000EASX1FiberLinkRemoteAread-onlycurrentRemoteA device card fiber port link status: 0:Down 1:Up
1.3.6.1.4.1.4756.20.420.40.1.9Columnf1000EASX1FiberOAMLoopedRemoteAread-onlycurrentRemoteA device card fiber port OAM looped: 0:Off 1:on
1.3.6.1.4.1.4756.20.420.40.1.10Columnf1000EASX1FiberLBTestRemoteAread-writecurrentForce remote device card to do fiber port LoopBack testing: 0:Off 1:Action
1.3.6.1.4.1.4756.20.420.40.1.11Columnf1000EASX1FiberOAMRLBStatusRemoteAread-onlycurrentRemoteA device card fiber port LoopBack testing status: 0:Off 1:Ok 2:Fail
1.3.6.1.4.1.4756.20.420.40.1.12Columnf1000EASX1FiberRemoPwrAbRemoteAread-onlycurrentRemoteA device card fiber port RemoteA Power status: 0:Abnormal 1:OK 2:None
1.3.6.1.4.1.4756.20.420.40.1.13Columnf1000EASX1FiberFEFRemoteAread-onlycurrentRemoteA device card fiber port FEF status: 0:Abnormal 1:OFF 2:Detected
1.3.6.1.4.1.4756.20.420.40.1.14Columnf1000EASX1FiberIngressRateRemoteAread-writecurrentRemoteA device card fiber Ingress Rate Limit: 0 = Unlimit input format: 64k(K),100m(M),100 If doesn't input the unit, the default was Mega. Limite Rate : 64K ~…
1.3.6.1.4.1.4756.20.420.40.1.15Columnf1000EASX1FiberEgressRateRemoteAread-writecurrentRemoteA device card fiber Egress Rate Limit: 0 = Unlimit input format: 64k(K),100m(M),100 If doesn't input the unit, the default was Mega. Limite Rate : 64K ~ …
1.3.6.1.4.1.4756.20.420.40.1.16Columnf1000EASX1UtpLinkRemoteAread-onlycurrentRemoteA device card UTP port link status: 0:Down 1:Up
1.3.6.1.4.1.4756.20.420.40.1.17Columnf1000EASX1UtpNegoRemoteAread-writecurrentRemoteA device card UTP port negotiation status: 0:Manual 1:Auto
1.3.6.1.4.1.4756.20.420.40.1.18Columnf1000EASX1UtpSpeedRemoteAread-writecurrentRemoteA device card UTP port speed setting: 0:10 Base-T 1:100 Base-TX 2:1000 Base-TX
1.3.6.1.4.1.4756.20.420.40.1.19Columnf1000EASX1UtpDuplexRemoteAread-writecurrentRemoteA device card UTP port duplex setting: 0:Half duplex mode 1:Full duplex mode
1.3.6.1.4.1.4756.20.420.40.1.20Columnf1000EASX1UtpSpeedStatusRemoteAread-onlycurrentRemoteA device card UTP port speed status: 0:10 Base-T 1:100 Base-TX 2:1000 Base-TX
1.3.6.1.4.1.4756.20.420.40.1.21Columnf1000EASX1UtpDuplexStatusRemoteAread-onlycurrentRemoteA device card UTP port duplex status: 0:Half duplex mode 1:Full duplex mode
1.3.6.1.4.1.4756.20.420.40.1.22Columnf1000EASX1UtpIngressRateRemoteAread-writecurrentRemoteA device card utp Ingress Rate Limit: 0 = Unlimit input format: 64k(K),100m(M),100 If doesn't input the unit, the default was Mega. Limite Rate : 64K ~ 9…
1.3.6.1.4.1.4756.20.420.40.1.23Columnf1000EASX1UtpEgressRateRemoteAread-writecurrentRemoteA device card utp Egress Rate Limit: 0 = Unlimit input format: 64k(K),100m(M),100 If doesn't input the unit, the default was Mega. Limite Rate : 64K ~ 99…
1.3.6.1.4.1.4756.20.420.40.1.24Columnf1000EASX1DeviceResetRemoteAread-writecurrentForce RemoteA device card to reset mode: 0:Off 1:Action
1.3.6.1.4.1.4756.20.420.40.1.25Columnf1000EASX1UtpActiveRemoteAread-writecurrentRemoteA device UTP port active mode: 0:Disable 1:Enable
1.3.6.1.4.1.4756.20.420.40.1.26Columnf1000EASX1OamChModeRemoteAread-writecurrentRemoteA device OAM Channel mode: 0:Disable 1:passive 2:Active
1.3.6.1.4.1.4756.20.420.40.1.27Columnf1000EASX1OamMaxPDUsRemoteAread-writecurrentRemoteA device OAM max OAMPDU size: 60-1518 Octets
1.3.6.1.4.1.4756.20.420.40.1.28Columnf1000EASX1FiberAlsRemoteAread-writecurrentRemoteA device card port Auto Laser Shutdown mode: 0:Disable 1:Enable
1.3.6.1.4.1.4756.20.420.40.1.29Columnf1000EASX1PauseFrameRemoteAread-writecurrentRemoteA device card pause frame mode: 0:Disable 1:Enable
1.3.6.1.4.1.4756.20.420.40.1.30Columnf1000EASX1FHRModeRemoteAread-writecurrentRemoteA device card FHR Mode: 0:Disable 1:Enable
1.3.6.1.4.1.4756.20.420.40.1.31Columnf1000EASX1FiberLLFDepPortRemoteAread-writecurrentRemoteA device card port Link Loss Forwarding depends on port Ethernet Rx link: 0:don't care 1:selected
1.3.6.1.4.1.4756.20.420.40.1.32Columnf1000EASX1UtpLLFDepPortRemoteAread-writecurrentRemoteA device card port Link Loss Forwarding depends on port Fiber Rx link: 0:don't care 1:selected
1.3.6.1.4.1.4756.20.420.40.1.33Columnf1000EASX1AdvanceFunsRemoteAread-writecurrentRemoteA device card Switch functions mode: 0:Normal 5:Static 802.1Q VLAN 6:Spanning Tree Protocol 7:802.1Q VLAN Trunk 9:Q in Q VLAN 11:Spanning Tree Protocol &…
1.3.6.1.4.1.4756.20.420.40.1.34Columnf1000EASX1FiberInfoROM1RemoteAread-onlycurrentRemoteA device card port INFORemoteAOM information 1 valid: 0:Invalid 1:Valid
1.3.6.1.4.1.4756.20.420.40.1.35Columnf1000EASX1FiberInfoROM2RemoteAread-onlycurrentRemoteA device card port INFORemoteAOM information 2 valid: 0:Invalid 1:Valid(replacing D/D function
1.3.6.1.4.1.4756.20.420.40.1.36Columnf1000EASX1FiberInfoSN1RemoteAread-onlycurrentRemoteA device card port INFORemoteAOM S/N 1
1.3.6.1.4.1.4756.20.420.40.1.37Columnf1000EASX1FiberInfoSN2RemoteAread-onlycurrentRemoteA device card port INFORemoteAOM S/N 2
1.3.6.1.4.1.4756.20.420.40.1.38Columnf1000EASX1FiberDDRemoteAread-onlycurrentRemoteA device card fiber port Digital Diagnostic function: 0:No 1:Yes
1.3.6.1.4.1.4756.20.420.40.1.39Columnf1000EASX1FiberDDVendorRemoteAread-onlycurrentRemoteA device card fiber port D/D information: Vendor name
1.3.6.1.4.1.4756.20.420.40.1.40Columnf1000EASX1FiberDDPartNoRemoteAread-onlycurrentRemoteA device card fiber port D/D information: Vendor part number
1.3.6.1.4.1.4756.20.420.40.1.41Columnf1000EASX1FiberDDVendorSNRemoteAread-onlycurrentRemoteA device card fiber port D/D information: Vendor Serial Number
1.3.6.1.4.1.4756.20.420.40.1.42Columnf1000EASX1FiberDDFiberTypeRemoteAread-onlycurrentRemoteA device card fiber port D/D information: Fiber Type
1.3.6.1.4.1.4756.20.420.40.1.43Columnf1000EASX1FiberDDWaveLenRemoteAread-onlycurrentRemoteA device card fiber port D/D information: Wave length
1.3.6.1.4.1.4756.20.420.40.1.44Columnf1000EASX1FiberDDWaveLen2RemoteAread-onlycurrentRemoteA device card fiber port D/D information: Wave length 2
1.3.6.1.4.1.4756.20.420.40.1.45Columnf1000EASX1FiberDDLinkLenRemoteAread-onlycurrentRemoteA device card fiber port D/D information: Link length
1.3.6.1.4.1.4756.20.420.40.1.46Columnf1000EASX1FiberDDLenUnitRemoteAread-onlycurrentRemoteA device card fiber port D/D information: Length Unit
1.3.6.1.4.1.4756.20.420.40.1.47Columnf1000EASX1FiberDDStatusRemoteAread-onlycurrentRemoteA device card fiber port D/D information: Status Support
1.3.6.1.4.1.4756.20.420.40.1.48Columnf1000EASX1FiberDDRxSensRemoteAread-onlycurrentRemoteA device card fiber port D/D information: Rx Sensitivity
1.3.6.1.4.1.4756.20.420.40.1.49Columnf1000EASX1FiberDDTxPWRRemoteAread-onlycurrentRemoteA device card fiber port D/D information: Tx power
1.3.6.1.4.1.4756.20.420.40.1.50Columnf1000EASX1FiberDDRxPWRRemoteAread-onlycurrentRemoteA device card fiber port D/D information: Rx power
1.3.6.1.4.1.4756.20.420.40.1.51Columnf1000EASX1FiberDDTempRemoteAread-onlycurrentRemoteA device card fiber port D/D information: Temperature in degree C
1.3.6.1.4.1.4756.20.420.40.1.52Columnf1000EASX1FiberDDPWRMarginRemoteAread-onlycurrentRemoteA device card fiber port D/D information: Power margin
1.3.6.1.4.1.4756.20.420.40.1.53Columnf1000EASX1FiberDDPWRLossRemoteAread-onlycurrentRemoteA device card fiber port D/D information: Power loss
1.3.6.1.4.1.4756.20.420.40.1.54Columnf1000EASX1ClrRMONCntsRemoteAread-writecurrentClear RemoteA device card RMON IN/OUT counters: 0:No action 1:Action
1.3.6.1.4.1.4756.20.420.40.1.55Columnf1000EASX1FiberRMONInRemoteAread-onlycurrentRemoteA device card port RMON IN counter.
1.3.6.1.4.1.4756.20.420.40.1.56Columnf1000EASX1FiberRMONOutRemoteAread-onlycurrentRemoteA device card port RMON OUT counter.
1.3.6.1.4.1.4756.20.420.40.1.57Columnf1000EASX1UtpRMONInRemoteAread-onlycurrentRemoteA device card port RMON IN counter.
1.3.6.1.4.1.4756.20.420.40.1.58Columnf1000EASX1UtpRMONOutRemoteAread-onlycurrentRemoteA device card port RMON OUT counter.
1.3.6.1.4.1.4756.20.420.40.1.59Columnf1000EASX1ClrOAMCntsRemoteAread-writecurrentClear RemoteA device card OAM counters: 0:No action 1:Action
1.3.6.1.4.1.4756.20.420.40.1.60Columnf1000EASX1IpModeRemoteAread-writecurrentOn Rack Ip Mode: 0:Enable 1:Disable
1.3.6.1.4.1.4756.20.420.40.1.61Columnf1000EASX1OamChTxRemoteAread-onlycurrentRemoteA device OAM Channel TX OAMPDU frame count
1.3.6.1.4.1.4756.20.420.40.1.62Columnf1000EASX1OamChRxRemoteAread-onlycurrentRemoteA device OAM Channel RX OAMPDU frame count
1.3.6.1.4.1.4756.20.420.40.1.63Columnf1000EASX1OamInfoChTxRemoteAread-onlycurrentRemoteA device OAM Channel TX Information OAMPDU frame count
1.3.6.1.4.1.4756.20.420.40.1.64Columnf1000EASX1OamInfoChRxRemoteAread-onlycurrentRemoteA device OAM Channel RX Information OAMPDU frame count
1.3.6.1.4.1.4756.20.420.40.1.65Columnf1000EASX1OamEventChTxRemoteAread-onlycurrentRemoteA device OAM Channel TX Event OAMPDU frame count
1.3.6.1.4.1.4756.20.420.40.1.66Columnf1000EASX1OamUniEvtChRxRemoteAread-onlycurrentRemoteA device OAM Channel RX Unique Event OAMPDU frame count
1.3.6.1.4.1.4756.20.420.40.1.67Columnf1000EASX1OamDupEvtChRxRemoteAread-onlycurrentRemoteA device OAM Channel RX Duplicate Event OAMPDU frame count
1.3.6.1.4.1.4756.20.420.40.1.68Columnf1000EASX1OamLbChTxRemoteAread-onlycurrentRemoteA device OAM Channel TX Loopback Control OAMPDU frame count
1.3.6.1.4.1.4756.20.420.40.1.69Columnf1000EASX1OamLbChRxRemoteAread-onlycurrentRemoteA device OAM Channel RX Loopback Control OAMPDU frame count
1.3.6.1.4.1.4756.20.420.40.1.70Columnf1000EASX1OamVarReqChTxRemoteAread-onlycurrentRemoteA device OAM Channel TX Variable Request OAMPDU frame count
1.3.6.1.4.1.4756.20.420.40.1.71Columnf1000EASX1OamVarReqChRxRemoteAread-onlycurrentRemoteA device OAM Channel RX Variable Request OAMPDU frame count
1.3.6.1.4.1.4756.20.420.40.1.72Columnf1000EASX1OamVarRspChTxRemoteAread-onlycurrentRemoteA device OAM Channel TX Variable Response OAMPDU frame count
1.3.6.1.4.1.4756.20.420.40.1.73Columnf1000EASX1OamVarRspChRxRemoteAread-onlycurrentRemoteA device OAM Channel RX Variable Response OAMPDU frame count
1.3.6.1.4.1.4756.20.420.40.1.74Columnf1000EASX1OamOuiChTxRemoteAread-onlycurrentRemoteA device OAM Channel TX OUI OAMPDU frame count
1.3.6.1.4.1.4756.20.420.40.1.75Columnf1000EASX1OamOuiChRxRemoteAread-onlycurrentRemoteA device OAM Channel RX OUI OAMPDU frame count
1.3.6.1.4.1.4756.20.420.40.1.76Columnf1000EASX1OamUnknowChRxRemoteAread-onlycurrentRemoteA device OAM Channel RX Unsupported OAMPDU frame count
1.3.6.1.4.1.4756.20.420.40.1.77Columnf1000EASX1FiberSpeedRemoteAread-onlycurrentRemoteA device Fiber speed : 0:1000 1:100
1.3.6.1.4.1.4756.20.420.40.1.78Columnf1000EASX1MacLearningRemoteAread-writecurrentRemoteA device Mac learning : 0:Disable 1:Enable
1.3.6.1.4.1.4756.20.420.40.1.79Columnf1000EASX1Port1VIDRemoteAread-writecurrentRemoteA device Port 1 VID :
1.3.6.1.4.1.4756.20.420.40.1.80Columnf1000EASX1Port2VIDRemoteAread-writecurrentRemoteA device Port 2 VID :
1.3.6.1.4.1.4756.20.420.40.1.81Columnf1000EASX1Port1QinQRemoteAread-writecurrentRemoteA device Port 1 Q in Q Support : 1:Disable 2:Enable
1.3.6.1.4.1.4756.20.420.40.1.82Columnf1000EASX1Port2QinQRemoteAread-writecurrentRemoteA device Port 2 Q in Q Support : 1:Disable 2:Enable
1.3.6.1.4.1.4756.20.420.40.1.83Columnf1000EASX1VID1RemoteAread-writecurrentRemoteA device VID 1:
1.3.6.1.4.1.4756.20.420.40.1.84Columnf1000EASX1VID2RemoteAread-writecurrentRemoteA device VID 2:
1.3.6.1.4.1.4756.20.420.40.1.85Columnf1000EASX1VID3RemoteAread-writecurrentRemoteA device VID 3:
1.3.6.1.4.1.4756.20.420.40.1.86Columnf1000EASX1VID4RemoteAread-writecurrentRemoteA device VID 4:
1.3.6.1.4.1.4756.20.420.40.1.87Columnf1000EASX1VID5RemoteAread-writecurrentRemoteA device VID 5:
1.3.6.1.4.1.4756.20.420.40.1.88Columnf1000EASX1VID6RemoteAread-writecurrentRemoteA device VID 6:
1.3.6.1.4.1.4756.20.420.40.1.89Columnf1000EASX1VID7RemoteAread-writecurrentRemoteA device VID 7:
1.3.6.1.4.1.4756.20.420.40.1.90Columnf1000EASX1VID8RemoteAread-writecurrentRemoteA device VID 8:
1.3.6.1.4.1.4756.20.420.40.1.91Columnf1000EASX1VID9RemoteAread-writecurrentRemoteA device VID 9:
1.3.6.1.4.1.4756.20.420.40.1.92Columnf1000EASX1VID10RemoteAread-writecurrentRemoteA device VID 10:
1.3.6.1.4.1.4756.20.420.40.1.93Columnf1000EASX1VID11RemoteAread-writecurrentRemoteA device VID 11:
1.3.6.1.4.1.4756.20.420.40.1.94Columnf1000EASX1VID12RemoteAread-writecurrentRemoteA device VID 12:
1.3.6.1.4.1.4756.20.420.40.1.95Columnf1000EASX1VID13RemoteAread-writecurrentRemoteA device VID 13:
1.3.6.1.4.1.4756.20.420.40.1.96Columnf1000EASX1VID14RemoteAread-writecurrentRemoteA device VID 14:
1.3.6.1.4.1.4756.20.420.40.1.97Columnf1000EASX1VID15RemoteAread-writecurrentRemoteA device VID 15:
1.3.6.1.4.1.4756.20.420.40.1.98Columnf1000EASX1VID16RemoteAread-writecurrentRemoteA device VID 16:
1.3.6.1.4.1.4756.20.420.40.1.99Columnf1000EASX1Port1Member1RemoteAread-writecurrentRemoteA device card port 1 member: 0:Unmodify 1:Untagged 2:Tagged 3:Nonmember
1.3.6.1.4.1.4756.20.420.40.1.100Columnf1000EASX1Port1Member2RemoteAread-writecurrentRemoteA device card port 1 member 2: 0:Unmodify 1:Untagged 2:Tagged 3:Nonmember
1.3.6.1.4.1.4756.20.420.40.1.101Columnf1000EASX1Port1Member3RemoteAread-writecurrentRemoteA device card port 1 member 3: 0:Unmodify 1:Untagged 2:Tagged 3:Nonmember
1.3.6.1.4.1.4756.20.420.40.1.102Columnf1000EASX1Port1Member4RemoteAread-writecurrentRemoteA device card port 1 member 4: 0:Unmodify 1:Untagged 2:Tagged 3:Nonmember
1.3.6.1.4.1.4756.20.420.40.1.103Columnf1000EASX1Port1Member5RemoteAread-writecurrentRemoteA device card port 1 member 5: 0:Unmodify 1:Untagged 2:Tagged 3:Nonmember
1.3.6.1.4.1.4756.20.420.40.1.104Columnf1000EASX1Port1Member6RemoteAread-writecurrentRemoteA device card port 1 member 6: 0:Unmodify 1:Untagged 2:Tagged 3:Nonmember
1.3.6.1.4.1.4756.20.420.40.1.105Columnf1000EASX1Port1Member7RemoteAread-writecurrentRemoteA device card port 1 member 7: 0:Unmodify 1:Untagged 2:Tagged 3:Nonmember
1.3.6.1.4.1.4756.20.420.40.1.106Columnf1000EASX1Port1Member8RemoteAread-writecurrentRemoteA device card port 1 member 8: 0:Unmodify 1:Untagged 2:Tagged 3:Nonmember
1.3.6.1.4.1.4756.20.420.40.1.107Columnf1000EASX1Port1Member9RemoteAread-writecurrentRemoteA device card port 1 member 9: 0:Unmodify 1:Untagged 2:Tagged 3:Nonmember
1.3.6.1.4.1.4756.20.420.40.1.108Columnf1000EASX1Port1Member10RemoteAread-writecurrentRemoteA device card port 1 member 10: 0:Unmodify 1:Untagged 2:Tagged 3:Nonmember
1.3.6.1.4.1.4756.20.420.40.1.109Columnf1000EASX1Port1Member11RemoteAread-writecurrentRemoteA device card port 1 member 11: 0:Unmodify 1:Untagged 2:Tagged 3:Nonmember
1.3.6.1.4.1.4756.20.420.40.1.110Columnf1000EASX1Port1Member12RemoteAread-writecurrentRemoteA device card port 1 member 12: 0:Unmodify 1:Untagged 2:Tagged 3:Nonmember
1.3.6.1.4.1.4756.20.420.40.1.111Columnf1000EASX1Port1Member13RemoteAread-writecurrentRemoteA device card port 1 member 13: 0:Unmodify 1:Untagged 2:Tagged 3:Nonmember
1.3.6.1.4.1.4756.20.420.40.1.112Columnf1000EASX1Port1Member14RemoteAread-writecurrentRemoteA device card port 1 member 14: 0:Unmodify 1:Untagged 2:Tagged 3:Nonmember
1.3.6.1.4.1.4756.20.420.40.1.113Columnf1000EASX1Port1Member15RemoteAread-writecurrentRemoteA device card port 1 member 15: 0:Unmodify 1:Untagged 2:Tagged 3:Nonmember
1.3.6.1.4.1.4756.20.420.40.1.114Columnf1000EASX1Port1Member16RemoteAread-writecurrentRemoteA device card port 1 member 16: 0:Unmodify 1:Untagged 2:Tagged 3:Nonmember
1.3.6.1.4.1.4756.20.420.40.1.115Columnf1000EASX1Port2Member1RemoteAread-writecurrentRemoteA device card port 2 member: 0:Unmodify 1:Untagged 2:Tagged 3:Nonmember
1.3.6.1.4.1.4756.20.420.40.1.116Columnf1000EASX1Port2Member2RemoteAread-writecurrentRemoteA device card port 2 member 2: 0:Unmodify 1:Untagged 2:Tagged 3:Nonmember
1.3.6.1.4.1.4756.20.420.40.1.117Columnf1000EASX1Port2Member3RemoteAread-writecurrentRemoteA device card port 2 member 3: 0:Unmodify 1:Untagged 2:Tagged 3:Nonmember
1.3.6.1.4.1.4756.20.420.40.1.118Columnf1000EASX1Port2Member4RemoteAread-writecurrentRemoteA device card port 2 member 4: 0:Unmodify 1:Untagged 2:Tagged 3:Nonmember
1.3.6.1.4.1.4756.20.420.40.1.119Columnf1000EASX1Port2Member5RemoteAread-writecurrentRemoteA device card port 2 member 5: 0:Unmodify 1:Untagged 2:Tagged 3:Nonmember
1.3.6.1.4.1.4756.20.420.40.1.120Columnf1000EASX1Port2Member6RemoteAread-writecurrentRemoteA device card port 2 member 6: 0:Unmodify 1:Untagged 2:Tagged 3:Nonmember
1.3.6.1.4.1.4756.20.420.40.1.121Columnf1000EASX1Port2Member7RemoteAread-writecurrentRemoteA device card port 2 member 7: 0:Unmodify 1:Untagged 2:Tagged 3:Nonmember
1.3.6.1.4.1.4756.20.420.40.1.122Columnf1000EASX1Port2Member8RemoteAread-writecurrentRemoteA device card port 2 member 8: 0:Unmodify 1:Untagged 2:Tagged 3:Nonmember
1.3.6.1.4.1.4756.20.420.40.1.123Columnf1000EASX1Port2Member9RemoteAread-writecurrentRemoteA device card port 2 member 9: 0:Unmodify 1:Untagged 2:Tagged 3:Nonmember
1.3.6.1.4.1.4756.20.420.40.1.124Columnf1000EASX1Port2Member10RemoteAread-writecurrentRemoteA device card port 2 member 10: 0:Unmodify 1:Untagged 2:Tagged 3:Nonmember
1.3.6.1.4.1.4756.20.420.40.1.125Columnf1000EASX1Port2Member11RemoteAread-writecurrentRemoteA device card port 2 member 11: 0:Unmodify 1:Untagged 2:Tagged 3:Nonmember
1.3.6.1.4.1.4756.20.420.40.1.126Columnf1000EASX1Port2Member12RemoteAread-writecurrentRemoteA device card port 2 member 12: 0:Unmodify 1:Untagged 2:Tagged 3:Nonmember
1.3.6.1.4.1.4756.20.420.40.1.127Columnf1000EASX1Port2Member13RemoteAread-writecurrentRemoteA device card port 2 member 13: 0:Unmodify 1:Untagged 2:Tagged 3:Nonmember
1.3.6.1.4.1.4756.20.420.40.1.128Columnf1000EASX1Port2Member14RemoteAread-writecurrentRemoteA device card port 2 member 14: 0:Unmodify 1:Untagged 2:Tagged 3:Nonmember
1.3.6.1.4.1.4756.20.420.40.1.129Columnf1000EASX1Port2Member15RemoteAread-writecurrentRemoteA device card port 2 member 15: 0:Unmodify 1:Untagged 2:Tagged 3:Nonmember
1.3.6.1.4.1.4756.20.420.40.1.130Columnf1000EASX1Port2Member16RemoteAread-writecurrentRemoteA device card port 2 member 16: 0:Unmodify 1:Untagged 2:Tagged 3:Nonmember
1.3.6.1.4.1.4756.20.420.40.1.131Columnf1000EASX1IpAddressRemoteAread-writecurrentRemoteA device IP address
1.3.6.1.4.1.4756.20.420.40.1.132Columnf1000EASX1NetMaskRemoteAread-writecurrentRemoteA device Netmask
1.3.6.1.4.1.4756.20.420.40.1.133Columnf1000EASX1GateWayRemoteAread-writecurrentRemoteA device Gateway
1.3.6.1.4.1.4756.20.420.40.1.134Columnf1000EASX1SetDefaultRemoteAread-writecurrentRemoteA device set to default
1.3.6.1.4.1.4756.20.420.40.1.135Columnf1000EASX1ManagementVIDRemoteAread-writecurrentRemoteA device Management VID :
1.3.6.1.4.1.4756.20.420.40.1.136Columnf1000EASX1TagTypeRemoteAread-writecurrentRemoteA device Tag Type (HEX) :
1.3.6.1.4.1.4756.20.420.40.1.137Columnf1000EASX1FxLinkAlarmRemoteAread-writecurrentRemoteA device fiber link alarm 0:Disable 1:Enable
1.3.6.1.4.1.4756.20.420.40.1.138Columnf1000EASX1UtpLinkAlarmRemoteAread-writecurrentRemoteA device utp link alarm 0:Disable 1:Enable
1.3.6.1.4.1.4756.20.420.40.1.139Columnf1000EASX1RemoteTLPTRemoteAread-writecurrentRemoteA device Remote TLPT mode : 0:Disalbe 1:Remote
1.3.6.1.4.1.4756.20.421Nodef1000EASX1RemoteBCards
1.3.6.1.4.1.4756.20.421.40Tablef1000EASX1RemoteBTablenot-accessiblecurrentA list of RemoteB 1000EAS/X-1 card entries.
1.3.6.1.4.1.4756.20.421.40.1Rowf1000EASX1RemoteBEntrynot-accessiblecurrentAn entry containing management information applicable to a particular RemoteB f1000EASX-1 card.
1.3.6.1.4.1.4756.20.421.40.1.1Columnf1000EASX1ChassisIndexRemoteBread-onlycurrentA unique value for each chassis ID. For CH20, it is the chassis ID. For CH08, it is always 0.
1.3.6.1.4.1.4756.20.421.40.1.2Columnf1000EASX1SlotIndexRemoteBread-onlycurrentA unique value for each RemoteB card. It is the slot location number.
1.3.6.1.4.1.4756.20.421.40.1.3Columnf1000EASX1CardHWVerRemoteBread-onlycurrentRemoteB device card hardware version x.xxx
1.3.6.1.4.1.4756.20.421.40.1.4Columnf1000EASX1CardFWVerRemoteBread-onlycurrentRemoteB device card firmware version x.xxx
1.3.6.1.4.1.4756.20.421.40.1.5Columnf1000EASX1CardCPLDVerRemoteBread-onlycurrentRemoteB device card CPLD version x.xxx
1.3.6.1.4.1.4756.20.421.40.1.6Columnf1000EASX1CardFPGAVerRemoteBread-onlycurrentRemoteB device card FPGA version x.xxx
1.3.6.1.4.1.4756.20.421.40.1.7Columnf1000EASX1ModelRemoteBread-onlycurrentRemoteB 1000EAS/X-1 Serial Type
1.3.6.1.4.1.4756.20.421.40.1.8Columnf1000EASX1FiberLinkRemoteBread-onlycurrentRemoteB device card fiber port link status: 0:Down 1:Up
1.3.6.1.4.1.4756.20.421.40.1.9Columnf1000EASX1FiberOAMLoopedRemoteBread-onlycurrentRemoteB device card fiber port OAM looped: 0:Off 1:on
1.3.6.1.4.1.4756.20.421.40.1.10Columnf1000EASX1FiberLBTestRemoteBread-writecurrentForce remote device card to do fiber port LoopBack testing: 0:Off 1:Action
1.3.6.1.4.1.4756.20.421.40.1.11Columnf1000EASX1FiberOAMRLBStatusRemoteBread-onlycurrentRemoteB device card fiber port LoopBack testing status: 0:Off 1:Ok 2:Fail
1.3.6.1.4.1.4756.20.421.40.1.12Columnf1000EASX1FiberRemoPwrAbRemoteBread-onlycurrentRemoteB device card fiber port RemoteB Power status: 0:Abnormal 1:OK 2:None
1.3.6.1.4.1.4756.20.421.40.1.13Columnf1000EASX1FiberFEFRemoteBread-onlycurrentRemoteB device card fiber port FEF status: 0:Abnormal 1:OFF 2:Detected
1.3.6.1.4.1.4756.20.421.40.1.14Columnf1000EASX1FiberIngressRateRemoteBread-writecurrentRemoteB device card fiber Ingress Rate Limit: 0 = Unlimit input format: 64k(K),100m(M),100 If doesn't input the unit, the default was Mega. Limite Rate : 64K ~…
1.3.6.1.4.1.4756.20.421.40.1.15Columnf1000EASX1FiberEgressRateRemoteBread-writecurrentRemoteB device card fiber Egress Rate Limit: 0 = Unlimit input format: 64k(K),100m(M),100 If doesn't input the unit, the default was Mega. Limite Rate : 64K ~ …
1.3.6.1.4.1.4756.20.421.40.1.16Columnf1000EASX1UtpLinkRemoteBread-onlycurrentRemoteB device card UTP port link status: 0:Down 1:Up
1.3.6.1.4.1.4756.20.421.40.1.17Columnf1000EASX1UtpNegoRemoteBread-writecurrentRemoteB device card UTP port negotiation status: 0:Manual 1:Auto
1.3.6.1.4.1.4756.20.421.40.1.18Columnf1000EASX1UtpSpeedRemoteBread-writecurrentRemoteB device card UTP port speed setting: 0:10 Base-T 1:100 Base-TX 2:1000 Base-TX
1.3.6.1.4.1.4756.20.421.40.1.19Columnf1000EASX1UtpDuplexRemoteBread-writecurrentRemoteB device card UTP port duplex setting: 0:Half duplex mode 1:Full duplex mode
1.3.6.1.4.1.4756.20.421.40.1.20Columnf1000EASX1UtpSpeedStatusRemoteBread-onlycurrentRemoteB device card UTP port speed status: 0:10 Base-T 1:100 Base-TX 2:1000 Base-TX
1.3.6.1.4.1.4756.20.421.40.1.21Columnf1000EASX1UtpDuplexStatusRemoteBread-onlycurrentRemoteB device card UTP port duplex status: 0:Half duplex mode 1:Full duplex mode
1.3.6.1.4.1.4756.20.421.40.1.22Columnf1000EASX1UtpIngressRateRemoteBread-writecurrentRemoteB device card utp Ingress Rate Limit: 0 = Unlimit input format: 64k(K),100m(M),100 If doesn't input the unit, the default was Mega. Limite Rate : 64K ~ 9…
1.3.6.1.4.1.4756.20.421.40.1.23Columnf1000EASX1UtpEgressRateRemoteBread-writecurrentRemoteB device card utp Egress Rate Limit: 0 = Unlimit input format: 64k(K),100m(M),100 If doesn't input the unit, the default was Mega. Limite Rate : 64K ~ 99…
1.3.6.1.4.1.4756.20.421.40.1.24Columnf1000EASX1DeviceResetRemoteBread-writecurrentForce RemoteB device card to reset mode: 0:Off 1:Action
1.3.6.1.4.1.4756.20.421.40.1.25Columnf1000EASX1UtpActiveRemoteBread-writecurrentRemoteB device UTP port active mode: 0:Disable 1:Enable
1.3.6.1.4.1.4756.20.421.40.1.26Columnf1000EASX1OamChModeRemoteBread-writecurrentRemoteB device OAM Channel mode: 0:Disable 1:passive 2:Active
1.3.6.1.4.1.4756.20.421.40.1.27Columnf1000EASX1OamMaxPDUsRemoteBread-writecurrentRemoteB device OAM max OAMPDU size: 60-1518 Octets
1.3.6.1.4.1.4756.20.421.40.1.28Columnf1000EASX1FiberAlsRemoteBread-writecurrentRemoteB device card port Auto Laser Shutdown mode: 0:Disable 1:Enable
1.3.6.1.4.1.4756.20.421.40.1.29Columnf1000EASX1PauseFrameRemoteBread-writecurrentRemoteB device card pause frame mode: 0:Disable 1:Enable
1.3.6.1.4.1.4756.20.421.40.1.30Columnf1000EASX1FHRModeRemoteBread-writecurrentRemoteB device card FHR Mode: 0:Disable 1:Enable
1.3.6.1.4.1.4756.20.421.40.1.31Columnf1000EASX1FiberLLFDepPortRemoteBread-writecurrentRemoteB device card port Link Loss Forwarding depends on port Ethernet Rx link: 0:don't care 1:selected
1.3.6.1.4.1.4756.20.421.40.1.32Columnf1000EASX1UtpLLFDepPortRemoteBread-writecurrentRemoteB device card port Link Loss Forwarding depends on port Fiber Rx link: 0:don't care 1:selected
1.3.6.1.4.1.4756.20.421.40.1.33Columnf1000EASX1AdvanceFunsRemoteBread-writecurrentRemoteB device card Switch functions mode: 0:Normal 5:Static 802.1Q VLAN 6:Spanning Tree Protocol 7:802.1Q VLAN Trunk 9:Q in Q VLAN 11:Spanning Tree Protocol &…
1.3.6.1.4.1.4756.20.421.40.1.34Columnf1000EASX1FiberInfoROM1RemoteBread-onlycurrentRemoteB device card port INFORemoteBOM information 1 valid: 0:Invalid 1:Valid
1.3.6.1.4.1.4756.20.421.40.1.35Columnf1000EASX1FiberInfoROM2RemoteBread-onlycurrentRemoteB device card port INFORemoteBOM information 2 valid: 0:Invalid 1:Valid(replacing D/D function
1.3.6.1.4.1.4756.20.421.40.1.36Columnf1000EASX1FiberInfoSN1RemoteBread-onlycurrentRemoteB device card port INFORemoteBOM S/N 1
1.3.6.1.4.1.4756.20.421.40.1.37Columnf1000EASX1FiberInfoSN2RemoteBread-onlycurrentRemoteB device card port INFORemoteBOM S/N 2
1.3.6.1.4.1.4756.20.421.40.1.38Columnf1000EASX1FiberDDRemoteBread-onlycurrentRemoteB device card fiber port Digital Diagnostic function: 0:No 1:Yes
1.3.6.1.4.1.4756.20.421.40.1.39Columnf1000EASX1FiberDDVendorRemoteBread-onlycurrentRemoteB device card fiber port D/D information: Vendor name
1.3.6.1.4.1.4756.20.421.40.1.40Columnf1000EASX1FiberDDPartNoRemoteBread-onlycurrentRemoteB device card fiber port D/D information: Vendor part number
1.3.6.1.4.1.4756.20.421.40.1.41Columnf1000EASX1FiberDDVendorSNRemoteBread-onlycurrentRemoteB device card fiber port D/D information: Vendor Serial Number
1.3.6.1.4.1.4756.20.421.40.1.42Columnf1000EASX1FiberDDFiberTypeRemoteBread-onlycurrentRemoteB device card fiber port D/D information: Fiber Type
1.3.6.1.4.1.4756.20.421.40.1.43Columnf1000EASX1FiberDDWaveLenRemoteBread-onlycurrentRemoteB device card fiber port D/D information: Wave length
1.3.6.1.4.1.4756.20.421.40.1.44Columnf1000EASX1FiberDDWaveLen2RemoteBread-onlycurrentRemoteB device card fiber port D/D information: Wave length 2
1.3.6.1.4.1.4756.20.421.40.1.45Columnf1000EASX1FiberDDLinkLenRemoteBread-onlycurrentRemoteB device card fiber port D/D information: Link length
1.3.6.1.4.1.4756.20.421.40.1.46Columnf1000EASX1FiberDDLenUnitRemoteBread-onlycurrentRemoteB device card fiber port D/D information: Length Unit
1.3.6.1.4.1.4756.20.421.40.1.47Columnf1000EASX1FiberDDStatusRemoteBread-onlycurrentRemoteB device card fiber port D/D information: Status Support
1.3.6.1.4.1.4756.20.421.40.1.48Columnf1000EASX1FiberDDRxSensRemoteBread-onlycurrentRemoteB device card fiber port D/D information: Rx Sensitivity
1.3.6.1.4.1.4756.20.421.40.1.49Columnf1000EASX1FiberDDTxPWRRemoteBread-onlycurrentRemoteB device card fiber port D/D information: Tx power
1.3.6.1.4.1.4756.20.421.40.1.50Columnf1000EASX1FiberDDRxPWRRemoteBread-onlycurrentRemoteB device card fiber port D/D information: Rx power
1.3.6.1.4.1.4756.20.421.40.1.51Columnf1000EASX1FiberDDTempRemoteBread-onlycurrentRemoteB device card fiber port D/D information: Temperature in degree C
1.3.6.1.4.1.4756.20.421.40.1.52Columnf1000EASX1FiberDDPWRMarginRemoteBread-onlycurrentRemoteB device card fiber port D/D information: Power margin
1.3.6.1.4.1.4756.20.421.40.1.53Columnf1000EASX1FiberDDPWRLossRemoteBread-onlycurrentRemoteB device card fiber port D/D information: Power loss
1.3.6.1.4.1.4756.20.421.40.1.54Columnf1000EASX1ClrRMONCntsRemoteBread-writecurrentClear RemoteB device card RMON IN/OUT counters: 0:No action 1:Action
1.3.6.1.4.1.4756.20.421.40.1.55Columnf1000EASX1FiberRMONInRemoteBread-onlycurrentRemoteB device card port RMON IN counter.
1.3.6.1.4.1.4756.20.421.40.1.56Columnf1000EASX1FiberRMONOutRemoteBread-onlycurrentRemoteB device card port RMON OUT counter.
1.3.6.1.4.1.4756.20.421.40.1.57Columnf1000EASX1UtpRMONInRemoteBread-onlycurrentRemoteB device card port RMON IN counter.
1.3.6.1.4.1.4756.20.421.40.1.58Columnf1000EASX1UtpRMONOutRemoteBread-onlycurrentRemoteB device card port RMON OUT counter.
1.3.6.1.4.1.4756.20.421.40.1.59Columnf1000EASX1ClrOAMCntsRemoteBread-writecurrentClear RemoteB device card OAM counters: 0:No action 1:Action
1.3.6.1.4.1.4756.20.421.40.1.60Columnf1000EASX1IpModeRemoteBread-writecurrentOn Rack Ip Mode: 0:Enable 1:Disable
1.3.6.1.4.1.4756.20.421.40.1.61Columnf1000EASX1OamChTxRemoteBread-onlycurrentRemoteB device OAM Channel TX OAMPDU frame count
1.3.6.1.4.1.4756.20.421.40.1.62Columnf1000EASX1OamChRxRemoteBread-onlycurrentRemoteB device OAM Channel RX OAMPDU frame count
1.3.6.1.4.1.4756.20.421.40.1.63Columnf1000EASX1OamInfoChTxRemoteBread-onlycurrentRemoteB device OAM Channel TX Information OAMPDU frame count
1.3.6.1.4.1.4756.20.421.40.1.64Columnf1000EASX1OamInfoChRxRemoteBread-onlycurrentRemoteB device OAM Channel RX Information OAMPDU frame count
1.3.6.1.4.1.4756.20.421.40.1.65Columnf1000EASX1OamEventChTxRemoteBread-onlycurrentRemoteB device OAM Channel TX Event OAMPDU frame count
1.3.6.1.4.1.4756.20.421.40.1.66Columnf1000EASX1OamUniEvtChRxRemoteBread-onlycurrentRemoteB device OAM Channel RX Unique Event OAMPDU frame count
1.3.6.1.4.1.4756.20.421.40.1.67Columnf1000EASX1OamDupEvtChRxRemoteBread-onlycurrentRemoteB device OAM Channel RX Duplicate Event OAMPDU frame count
1.3.6.1.4.1.4756.20.421.40.1.68Columnf1000EASX1OamLbChTxRemoteBread-onlycurrentRemoteB device OAM Channel TX Loopback Control OAMPDU frame count
1.3.6.1.4.1.4756.20.421.40.1.69Columnf1000EASX1OamLbChRxRemoteBread-onlycurrentRemoteB device OAM Channel RX Loopback Control OAMPDU frame count
1.3.6.1.4.1.4756.20.421.40.1.70Columnf1000EASX1OamVarReqChTxRemoteBread-onlycurrentRemoteB device OAM Channel TX Variable Request OAMPDU frame count
1.3.6.1.4.1.4756.20.421.40.1.71Columnf1000EASX1OamVarReqChRxRemoteBread-onlycurrentRemoteB device OAM Channel RX Variable Request OAMPDU frame count
1.3.6.1.4.1.4756.20.421.40.1.72Columnf1000EASX1OamVarRspChTxRemoteBread-onlycurrentRemoteB device OAM Channel TX Variable Response OAMPDU frame count
1.3.6.1.4.1.4756.20.421.40.1.73Columnf1000EASX1OamVarRspChRxRemoteBread-onlycurrentRemoteB device OAM Channel RX Variable Response OAMPDU frame count
1.3.6.1.4.1.4756.20.421.40.1.74Columnf1000EASX1OamOuiChTxRemoteBread-onlycurrentRemoteB device OAM Channel TX OUI OAMPDU frame count
1.3.6.1.4.1.4756.20.421.40.1.75Columnf1000EASX1OamOuiChRxRemoteBread-onlycurrentRemoteB device OAM Channel RX OUI OAMPDU frame count
1.3.6.1.4.1.4756.20.421.40.1.76Columnf1000EASX1OamUnknowChRxRemoteBread-onlycurrentRemoteB device OAM Channel RX Unsupported OAMPDU frame count
1.3.6.1.4.1.4756.20.421.40.1.77Columnf1000EASX1FiberSpeedRemoteBread-onlycurrentRemoteB device Fiber speed : 0:1000 1:100
1.3.6.1.4.1.4756.20.421.40.1.78Columnf1000EASX1MacLearningRemoteBread-writecurrentRemoteB device Mac learning : 0:Disable 1:Enable
1.3.6.1.4.1.4756.20.421.40.1.79Columnf1000EASX1Port1VIDRemoteBread-writecurrentRemoteB device Port 1 VID :
1.3.6.1.4.1.4756.20.421.40.1.80Columnf1000EASX1Port2VIDRemoteBread-writecurrentRemoteB device Port 2 VID :
1.3.6.1.4.1.4756.20.421.40.1.81Columnf1000EASX1Port1QinQRemoteBread-writecurrentRemoteB device Port 1 Q in Q Support : 1:Disable 2:Enable
1.3.6.1.4.1.4756.20.421.40.1.82Columnf1000EASX1Port2QinQRemoteBread-writecurrentRemoteB device Port 2 Q in Q Support : 1:Disable 2:Enable
1.3.6.1.4.1.4756.20.421.40.1.83Columnf1000EASX1VID1RemoteBread-writecurrentRemoteB device VID 1:
1.3.6.1.4.1.4756.20.421.40.1.84Columnf1000EASX1VID2RemoteBread-writecurrentRemoteB device VID 2:
1.3.6.1.4.1.4756.20.421.40.1.85Columnf1000EASX1VID3RemoteBread-writecurrentRemoteB device VID 3:
1.3.6.1.4.1.4756.20.421.40.1.86Columnf1000EASX1VID4RemoteBread-writecurrentRemoteB device VID 4:
1.3.6.1.4.1.4756.20.421.40.1.87Columnf1000EASX1VID5RemoteBread-writecurrentRemoteB device VID 5:
1.3.6.1.4.1.4756.20.421.40.1.88Columnf1000EASX1VID6RemoteBread-writecurrentRemoteB device VID 6:
1.3.6.1.4.1.4756.20.421.40.1.89Columnf1000EASX1VID7RemoteBread-writecurrentRemoteB device VID 7:
1.3.6.1.4.1.4756.20.421.40.1.90Columnf1000EASX1VID8RemoteBread-writecurrentRemoteB device VID 8:
1.3.6.1.4.1.4756.20.421.40.1.91Columnf1000EASX1VID9RemoteBread-writecurrentRemoteB device VID 9:
1.3.6.1.4.1.4756.20.421.40.1.92Columnf1000EASX1VID10RemoteBread-writecurrentRemoteB device VID 10:
1.3.6.1.4.1.4756.20.421.40.1.93Columnf1000EASX1VID11RemoteBread-writecurrentRemoteB device VID 11:
1.3.6.1.4.1.4756.20.421.40.1.94Columnf1000EASX1VID12RemoteBread-writecurrentRemoteB device VID 12:
1.3.6.1.4.1.4756.20.421.40.1.95Columnf1000EASX1VID13RemoteBread-writecurrentRemoteB device VID 13:
1.3.6.1.4.1.4756.20.421.40.1.96Columnf1000EASX1VID14RemoteBread-writecurrentRemoteB device VID 14:
1.3.6.1.4.1.4756.20.421.40.1.97Columnf1000EASX1VID15RemoteBread-writecurrentRemoteB device VID 15:
1.3.6.1.4.1.4756.20.421.40.1.98Columnf1000EASX1VID16RemoteBread-writecurrentRemoteB device VID 16:
1.3.6.1.4.1.4756.20.421.40.1.99Columnf1000EASX1Port1Member1RemoteBread-writecurrentRemoteB device card port 1 member: 0:Unmodify 1:Untagged 2:Tagged 3:Nonmember
1.3.6.1.4.1.4756.20.421.40.1.100Columnf1000EASX1Port1Member2RemoteBread-writecurrentRemoteB device card port 1 member 2: 0:Unmodify 1:Untagged 2:Tagged 3:Nonmember
1.3.6.1.4.1.4756.20.421.40.1.101Columnf1000EASX1Port1Member3RemoteBread-writecurrentRemoteB device card port 1 member 3: 0:Unmodify 1:Untagged 2:Tagged 3:Nonmember
1.3.6.1.4.1.4756.20.421.40.1.102Columnf1000EASX1Port1Member4RemoteBread-writecurrentRemoteB device card port 1 member 4: 0:Unmodify 1:Untagged 2:Tagged 3:Nonmember
1.3.6.1.4.1.4756.20.421.40.1.103Columnf1000EASX1Port1Member5RemoteBread-writecurrentRemoteB device card port 1 member 5: 0:Unmodify 1:Untagged 2:Tagged 3:Nonmember
1.3.6.1.4.1.4756.20.421.40.1.104Columnf1000EASX1Port1Member6RemoteBread-writecurrentRemoteB device card port 1 member 6: 0:Unmodify 1:Untagged 2:Tagged 3:Nonmember
1.3.6.1.4.1.4756.20.421.40.1.105Columnf1000EASX1Port1Member7RemoteBread-writecurrentRemoteB device card port 1 member 7: 0:Unmodify 1:Untagged 2:Tagged 3:Nonmember
1.3.6.1.4.1.4756.20.421.40.1.106Columnf1000EASX1Port1Member8RemoteBread-writecurrentRemoteB device card port 1 member 8: 0:Unmodify 1:Untagged 2:Tagged 3:Nonmember
1.3.6.1.4.1.4756.20.421.40.1.107Columnf1000EASX1Port1Member9RemoteBread-writecurrentRemoteB device card port 1 member 9: 0:Unmodify 1:Untagged 2:Tagged 3:Nonmember
1.3.6.1.4.1.4756.20.421.40.1.108Columnf1000EASX1Port1Member10RemoteBread-writecurrentRemoteB device card port 1 member 10: 0:Unmodify 1:Untagged 2:Tagged 3:Nonmember
1.3.6.1.4.1.4756.20.421.40.1.109Columnf1000EASX1Port1Member11RemoteBread-writecurrentRemoteB device card port 1 member 11: 0:Unmodify 1:Untagged 2:Tagged 3:Nonmember
1.3.6.1.4.1.4756.20.421.40.1.110Columnf1000EASX1Port1Member12RemoteBread-writecurrentRemoteB device card port 1 member 12: 0:Unmodify 1:Untagged 2:Tagged 3:Nonmember
1.3.6.1.4.1.4756.20.421.40.1.111Columnf1000EASX1Port1Member13RemoteBread-writecurrentRemoteB device card port 1 member 13: 0:Unmodify 1:Untagged 2:Tagged 3:Nonmember
1.3.6.1.4.1.4756.20.421.40.1.112Columnf1000EASX1Port1Member14RemoteBread-writecurrentRemoteB device card port 1 member 14: 0:Unmodify 1:Untagged 2:Tagged 3:Nonmember
1.3.6.1.4.1.4756.20.421.40.1.113Columnf1000EASX1Port1Member15RemoteBread-writecurrentRemoteB device card port 1 member 15: 0:Unmodify 1:Untagged 2:Tagged 3:Nonmember
1.3.6.1.4.1.4756.20.421.40.1.114Columnf1000EASX1Port1Member16RemoteBread-writecurrentRemoteB device card port 1 member 16: 0:Unmodify 1:Untagged 2:Tagged 3:Nonmember
1.3.6.1.4.1.4756.20.421.40.1.115Columnf1000EASX1Port2Member1RemoteBread-writecurrentRemoteB device card port 2 member: 0:Unmodify 1:Untagged 2:Tagged 3:Nonmember
1.3.6.1.4.1.4756.20.421.40.1.116Columnf1000EASX1Port2Member2RemoteBread-writecurrentRemoteB device card port 2 member 2: 0:Unmodify 1:Untagged 2:Tagged 3:Nonmember
1.3.6.1.4.1.4756.20.421.40.1.117Columnf1000EASX1Port2Member3RemoteBread-writecurrentRemoteB device card port 2 member 3: 0:Unmodify 1:Untagged 2:Tagged 3:Nonmember
1.3.6.1.4.1.4756.20.421.40.1.118Columnf1000EASX1Port2Member4RemoteBread-writecurrentRemoteB device card port 2 member 4: 0:Unmodify 1:Untagged 2:Tagged 3:Nonmember
1.3.6.1.4.1.4756.20.421.40.1.119Columnf1000EASX1Port2Member5RemoteBread-writecurrentRemoteB device card port 2 member 5: 0:Unmodify 1:Untagged 2:Tagged 3:Nonmember
1.3.6.1.4.1.4756.20.421.40.1.120Columnf1000EASX1Port2Member6RemoteBread-writecurrentRemoteB device card port 2 member 6: 0:Unmodify 1:Untagged 2:Tagged 3:Nonmember
1.3.6.1.4.1.4756.20.421.40.1.121Columnf1000EASX1Port2Member7RemoteBread-writecurrentRemoteB device card port 2 member 7: 0:Unmodify 1:Untagged 2:Tagged 3:Nonmember
1.3.6.1.4.1.4756.20.421.40.1.122Columnf1000EASX1Port2Member8RemoteBread-writecurrentRemoteB device card port 2 member 8: 0:Unmodify 1:Untagged 2:Tagged 3:Nonmember
1.3.6.1.4.1.4756.20.421.40.1.123Columnf1000EASX1Port2Member9RemoteBread-writecurrentRemoteB device card port 2 member 9: 0:Unmodify 1:Untagged 2:Tagged 3:Nonmember
1.3.6.1.4.1.4756.20.421.40.1.124Columnf1000EASX1Port2Member10RemoteBread-writecurrentRemoteB device card port 2 member 10: 0:Unmodify 1:Untagged 2:Tagged 3:Nonmember
1.3.6.1.4.1.4756.20.421.40.1.125Columnf1000EASX1Port2Member11RemoteBread-writecurrentRemoteB device card port 2 member 11: 0:Unmodify 1:Untagged 2:Tagged 3:Nonmember
1.3.6.1.4.1.4756.20.421.40.1.126Columnf1000EASX1Port2Member12RemoteBread-writecurrentRemoteB device card port 2 member 12: 0:Unmodify 1:Untagged 2:Tagged 3:Nonmember
1.3.6.1.4.1.4756.20.421.40.1.127Columnf1000EASX1Port2Member13RemoteBread-writecurrentRemoteB device card port 2 member 13: 0:Unmodify 1:Untagged 2:Tagged 3:Nonmember
1.3.6.1.4.1.4756.20.421.40.1.128Columnf1000EASX1Port2Member14RemoteBread-writecurrentRemoteB device card port 2 member 14: 0:Unmodify 1:Untagged 2:Tagged 3:Nonmember
1.3.6.1.4.1.4756.20.421.40.1.129Columnf1000EASX1Port2Member15RemoteBread-writecurrentRemoteB device card port 2 member 15: 0:Unmodify 1:Untagged 2:Tagged 3:Nonmember
1.3.6.1.4.1.4756.20.421.40.1.130Columnf1000EASX1Port2Member16RemoteBread-writecurrentRemoteB device card port 2 member 16: 0:Unmodify 1:Untagged 2:Tagged 3:Nonmember
1.3.6.1.4.1.4756.20.421.40.1.131Columnf1000EASX1IpAddressRemoteBread-writecurrentRemoteB device IP address
1.3.6.1.4.1.4756.20.421.40.1.132Columnf1000EASX1NetMaskRemoteBread-writecurrentRemoteB device Netmask
1.3.6.1.4.1.4756.20.421.40.1.133Columnf1000EASX1GateWayRemoteBread-writecurrentRemoteB device Gateway
1.3.6.1.4.1.4756.20.421.40.1.134Columnf1000EASX1SetDefaultRemoteBread-writecurrentRemoteB device set to default
1.3.6.1.4.1.4756.20.421.40.1.135Columnf1000EASX1ManagementVIDRemoteBread-writecurrentRemoteB device Management VID :
1.3.6.1.4.1.4756.20.421.40.1.136Columnf1000EASX1TagTypeRemoteBread-writecurrentRemoteB device Tag Type (HEX) :
1.3.6.1.4.1.4756.20.421.40.1.137Columnf1000EASX1FxLinkAlarmRemoteBread-writecurrentRemoteB device fiber link alarm 0:Disable 1:Enable
1.3.6.1.4.1.4756.20.421.40.1.138Columnf1000EASX1UtpLinkAlarmRemoteBread-writecurrentRemoteB device utp link alarm 0:Disable 1:Enable
1.3.6.1.4.1.4756.20.421.40.1.139Columnf1000EASX1RemoteTLPTRemoteBread-writecurrentRemoteB device Remote TLPT mode : 0:Disalbe 1:Remote
1.3.6.1.4.1.4756.20.430Nodef4E1LocalCards
1.3.6.1.4.1.4756.20.430.20Tablef4E1LocalTablenot-accessiblecurrentA list of local FRM220A-iMux4 series card entries. The number of entries is f5E1-No-L.
1.3.6.1.4.1.4756.20.430.20.1Rowf4E1LocalEntrynot-accessiblecurrentAn entry containing management information applicable to a particular local FRM220A-iMux4 series card.
1.3.6.1.4.1.4756.20.430.20.1.1Columnfa4e1et100ChassisIndexLocalread-onlycurrentA unique value for each card. It starts from 0 to 9 contiguously.
1.3.6.1.4.1.4756.20.430.20.1.2Columnfa4e1et100SlotIndexLocalread-onlycurrentA unique value for each card. It starts from 1 to 20 contiguously.
1.3.6.1.4.1.4756.20.430.20.1.3Columnfa4e1et100CardHWVerLocalread-onlycurrentiMux4(T/S) Series card hardware version x.xxx
1.3.6.1.4.1.4756.20.430.20.1.4Columnfa4e1et100CardFWVerLocalread-onlycurrentiMux4(T/S) Series card firmware version x.xxx
1.3.6.1.4.1.4756.20.430.20.1.5Columnfa4e1et100CardCPLDVerLocalread-onlycurrentiMux4(T/S) Series card CPLD version x.xxx
1.3.6.1.4.1.4756.20.430.20.1.6Columnfa4e1et100CardFPGAVerLocalread-onlycurrentiMux4(T/S) Series card FPGA version x.xxx
1.3.6.1.4.1.4756.20.430.20.1.7Columnfa4e1et100ModelLocalread-onlycurrentCard Type: 0:iMux4T 1:iMux4S
1.3.6.1.4.1.4756.20.430.20.1.8Columnfa4e1et100SystemStatusLocalread-onlycurrentiMux4(T/S) Series card system status: 0:Normal 1:Alarm
1.3.6.1.4.1.4756.20.430.20.1.9Columnfa4e1et100DeviceActiveLocalread-writecurrentiMux4(T/S) Series card active: 0:Disable 1:Enable
1.3.6.1.4.1.4756.20.430.20.1.10Columnfa4e1et100SetToDefaultLocalread-writecurrentiMux4(T/S) Series card port set to default: 0:Off 1:Trigger
1.3.6.1.4.1.4756.20.430.20.1.11Columnfa4e1et100E1Ch1SingalLocalread-onlycurrentiMux4(T/S) Series card E1 channel 1 signal status: 0:Singal Loss 1:Normal
1.3.6.1.4.1.4756.20.430.20.1.12Columnfa4e1et100E1Ch2SingalLocalread-onlycurrentiMux4(T/S) Series card E1 channel 2 signal status: 0:Singal Loss 1:Normal
1.3.6.1.4.1.4756.20.430.20.1.13Columnfa4e1et100E1Ch3SingalLocalread-onlycurrentiMux4(T/S) Series card E1 channel 3 signal status: 0:Singal Loss 1:Normal
1.3.6.1.4.1.4756.20.430.20.1.14Columnfa4e1et100E1Ch4SingalLocalread-onlycurrentiMux4(T/S) Series card E1 channel 4 signal status: 0:Singal Loss 1:Normal
1.3.6.1.4.1.4756.20.430.20.1.15Columnfa4e1et100E1Ch1SyncLocalread-onlycurrentiMux4(T/S) Series card E1 channel 1 sync status: 0:Sync Loss 1:Sync
1.3.6.1.4.1.4756.20.430.20.1.16Columnfa4e1et100E1Ch2SyncLocalread-onlycurrentiMux4(T/S) Series card E1 channel 2 sync status: 0:Sync Loss 1:Sync
1.3.6.1.4.1.4756.20.430.20.1.17Columnfa4e1et100E1Ch3SyncLocalread-onlycurrentiMux4(T/S) Series card E1 channel 3 sync status: 0:Sync Loss 1:Sync
1.3.6.1.4.1.4756.20.430.20.1.18Columnfa4e1et100E1Ch4SyncLocalread-onlycurrentiMux4(T/S) Series card E1 channel 4 sync status: 0:Sync Loss 1:Sync
1.3.6.1.4.1.4756.20.430.20.1.19Columnfa4e1et100E1Ch1RecvAISLocalread-onlycurrentiMux4(T/S) Series card E1 channel 1 receive AIS status: 0:No 1:Yes
1.3.6.1.4.1.4756.20.430.20.1.20Columnfa4e1et100E1Ch2RecvAISLocalread-onlycurrentiMux4(T/S) Series card E1 channel 2 receive AIS status: 0:No 1:Yes
1.3.6.1.4.1.4756.20.430.20.1.21Columnfa4e1et100E1Ch3RecvAISLocalread-onlycurrentiMux4(T/S) Series card E1 channel 3 receive AIS status: 0:No 1:Yes
1.3.6.1.4.1.4756.20.430.20.1.22Columnfa4e1et100E1Ch4RecvAISLocalread-onlycurrentiMux4(T/S) Series card E1 channel 4 receive AIS status: 0:No 1:Yes
1.3.6.1.4.1.4756.20.430.20.1.23Columnfa4e1et100E1Ch1ConnTypeLocalread-onlycurrentiMux4(T/S) Series card E1 channel 1 connector type: 0:RJ-48C 1:BNC
1.3.6.1.4.1.4756.20.430.20.1.24Columnfa4e1et100E1Ch2ConnTypeLocalread-onlycurrentiMux4(T/S) Series card E1 channel 2 connector type: 0:RJ-48C 1:BNC
1.3.6.1.4.1.4756.20.430.20.1.25Columnfa4e1et100E1Ch3ConnTypeLocalread-onlycurrentiMux4(T/S) Series card E1 channel 3 connector type: 0:RJ-48C 1:BNC
1.3.6.1.4.1.4756.20.430.20.1.26Columnfa4e1et100E1Ch4ConnTypeLocalread-onlycurrentiMux4(T/S) Series card E1 channel 4 connector type: 0:RJ-48C 1:BNC
1.3.6.1.4.1.4756.20.430.20.1.27Columnfa4e1et100E1Ch1RAILocalread-onlycurrentiMux4(T/S) Series card E1 channel 1 RAI status: 0:No 1:Yes
1.3.6.1.4.1.4756.20.430.20.1.28Columnfa4e1et100E1Ch2RAILocalread-onlycurrentiMux4(T/S) Series card E1 channel 2 RAI status: 0:No 1:Yes
1.3.6.1.4.1.4756.20.430.20.1.29Columnfa4e1et100E1Ch3RAILocalread-onlycurrentiMux4(T/S) Series card E1 channel 3 RAI status: 0:No 1:Yes
1.3.6.1.4.1.4756.20.430.20.1.30Columnfa4e1et100E1Ch4RAILocalread-onlycurrentiMux4(T/S) Series card E1 channel 4 RAI status: 0:No 1:Yes
1.3.6.1.4.1.4756.20.430.20.1.31Columnfa4e1et100E1Ch1LOMFLocalread-onlycurrentiMux4(T/S) Series card E1 channel 1 LOMF status: 0:No 1:Yes
1.3.6.1.4.1.4756.20.430.20.1.32Columnfa4e1et100E1Ch2LOMFLocalread-onlycurrentiMux4(T/S) Series card E1 channel 2 LOMF status: 0:No 1:Yes
1.3.6.1.4.1.4756.20.430.20.1.33Columnfa4e1et100E1Ch3LOMFLocalread-onlycurrentiMux4(T/S) Series card E1 channel 3 LOMF status: 0:No 1:Yes
1.3.6.1.4.1.4756.20.430.20.1.34Columnfa4e1et100E1Ch4LOMFLocalread-onlycurrentiMux4(T/S) Series card E1 channel 4 LOMF status: 0:No 1:Yes
1.3.6.1.4.1.4756.20.430.20.1.35Columnfa4e1et100E1Ch1ActiveLocalread-onlycurrentiMux4(T/S) Series card E1 channel 1 active status: 0:Inactive 1:Active
1.3.6.1.4.1.4756.20.430.20.1.36Columnfa4e1et100E1Ch2ActiveLocalread-onlycurrentiMux4(T/S) Series card E1 channel 2 active status: 0:Inactive 1:Active
1.3.6.1.4.1.4756.20.430.20.1.37Columnfa4e1et100E1Ch3ActiveLocalread-onlycurrentiMux4(T/S) Series card E1 channel 3 active status: 0:Inactive 1:Active
1.3.6.1.4.1.4756.20.430.20.1.38Columnfa4e1et100E1Ch4ActiveLocalread-onlycurrentiMux4(T/S) Series card E1 channel 4 active status: 0:Inactive 1:Active
1.3.6.1.4.1.4756.20.430.20.1.39Columnfa4e1et100E1Ch1LoopBackLocalread-writecurrentiMux4(T/S) Series card port E1 channel 1 loop back: 0:Off 2:RLB (Max used 3 channels)
1.3.6.1.4.1.4756.20.430.20.1.40Columnfa4e1et100E1Ch2LoopBackLocalread-writecurrentiMux4(T/S) Series card port E1 channel 2 loop back: 0:Off 2:RLB (Max used 3 channels)
1.3.6.1.4.1.4756.20.430.20.1.41Columnfa4e1et100E1Ch3LoopBackLocalread-writecurrentiMux4(T/S) Series card port E1 channel 3 loop back: 0:Off 2:RLB (Max used 3 channels)
1.3.6.1.4.1.4756.20.430.20.1.42Columnfa4e1et100E1Ch4LoopBackLocalread-writecurrentiMux4(T/S) Series card port E1 channel 4 loop back: 0:Off 2:RLB (Max used 3 channels)
1.3.6.1.4.1.4756.20.430.20.1.43Columnfa4e1et100FxLinkLocalread-onlycurrent5E1-ET100S Series card Fiber siganl detect status: 0:Down or Fiber unplugged 1:Up or Singal detected
1.3.6.1.4.1.4756.20.430.20.1.44Columnfa4e1et100FxLaserLocalread-onlycurrent5E1-ET100S Series card laser status: 0:Normal 1:Error
1.3.6.1.4.1.4756.20.430.20.1.45Columnfa4e1et100FxActiveLocalread-writecurrent5E1-ET100S Series card Fiber active: 0:Inactive 1:Active
1.3.6.1.4.1.4756.20.430.20.1.46Columnfa4e1et100FxLaserOutputLocalread-writecurrent5E1-ET100S Series card laser output: 0:disable 1:Enable
1.3.6.1.4.1.4756.20.430.20.1.47Columnfa4e1et100FxOpModeLocalread-writecurrent5E1-ET100S Series card operation mode: 0:Switch 1:Convert
1.3.6.1.4.1.4756.20.430.20.1.48Columnfa4e1et100UtpLinkLocalread-onlycurrent5E1-ET100T Series card UTP link status: 0:Link Down 1:Link Up
1.3.6.1.4.1.4756.20.430.20.1.49Columnfa4e1et100UtpStatusLocalread-onlycurrent5E1-ET100T Series card UTP link mode status: 0:None, Maybe link down 1:Link at 10Mbps, Half duplex 2:Link at 10Mbps, Full duplex 3:Link at 100Mbps, Half duplex…
1.3.6.1.4.1.4756.20.430.20.1.50Columnfa4e1et100UtpFlowCtrlStsLocalread-onlycurrent5E1-ET100T Series card UTP flow control status: 0:Disable 1:Enable
1.3.6.1.4.1.4756.20.430.20.1.51Columnfa4e1et100UtpModeLocalread-writecurrent5E1-ET100T Series card UTP mode: 0:Disable 1:Enable and autoNegotiation 3:Enable and force to 10Mbps, Half duplex 4:Enable and force to 10Mbps, Full duplex 5:E…
1.3.6.1.4.1.4756.20.430.20.1.52Columnfa4e1et100UtpFlowCtrlLocalread-writecurrent5E1-ET100T Series card UTP flow control: 0:Disable 1:Enable
1.3.6.1.4.1.4756.20.430.20.1.53Columnfa4e1et100SpeedLimitLocalread-writecurrentiMux4(T/S) Series card speed limit: Limited = this value * 32Kbps, this value is restricted to 0 ~ 3125, 0 to disable
1.3.6.1.4.1.4756.20.430.20.1.54Columnfa4e1et100VlanAwareLocalread-writecurrentiMux4(T/S) Series card 802.1q VLAN tag aware: 0:Disable 1:Enable
1.3.6.1.4.1.4756.20.430.20.1.55Columnfa4e1et100VlanIDLocalread-writecurrentiMux4(T/S) Series card VLAN ID: The ID is restricted to 1 ~ 4094
1.3.6.1.4.1.4756.20.430.20.1.56Columnfa4e1et100RemoteDeviceLocalread-onlycurrentFRM220A-5E1 Series card remote device status: 0:Link Down 1:Link Up
1.3.6.1.4.1.4756.20.430.20.1.57Columnfa4e1et100RemotePowerLocalread-onlycurrentiMux4(T/S) Series card remote device power status: 0:Normal 1:Power off
1.3.6.1.4.1.4756.20.430.20.1.58Columnfa4e1et100TimingSourceLocalread-writecurrentiMux4(T/S) Series card clock: 0:Internal oscillatro 1:Recovery from E1 channel 1 2:Recovery from E1 channel 2 3:Recovery from E1 channel 3 4:Recovery from E1 c…
1.3.6.1.4.1.4756.20.430.20.1.59Columnfa4e1et100FCSofGFPLocalread-writecurrentiMux4(T/S) Series card FCS of GFP: 0:Disable 1:Enable
1.3.6.1.4.1.4756.20.430.20.1.60Columnfa4e1et100AutoChAdjustLocalread-writecurrentiMux4(T/S) Series card auto channel Bdjust: 0:Disable 1:Enable
1.3.6.1.4.1.4756.20.430.20.1.61Columnfa4e1et100PayloadScrambleLocalread-writecurrentiMux4(T/S) Series card payload scramble: 0:Disable 1:Enable
1.3.6.1.4.1.4756.20.430.20.1.62Columnfa4e1et100FailoverLocalread-writecurrentiMux4(T/S) Series card failover: 0:Disable 1:Enable
1.3.6.1.4.1.4756.20.430.20.1.63Columnfa4e1et100LOMLocalread-onlycurrentiMux4(T/S) Series card LOM status: 0:No 1:Yes
1.3.6.1.4.1.4756.20.430.20.1.64Columnfa4e1et100SQMLocalread-onlycurrentiMux4(T/S) Series card SQM status: 0:No 1:Yes
1.3.6.1.4.1.4756.20.430.20.1.65Columnfa4e1et100CRCLocalread-onlycurrentiMux4(T/S) Series card CRC status: 0:No 1:Yes
1.3.6.1.4.1.4756.20.430.20.1.66Columnfa4e1et100LOALocalread-onlycurrentiMux4(T/S) Series card LOA status: 0:No 1:Yes
1.3.6.1.4.1.4756.20.430.20.1.67Columnfa4e1et100LFDLocalread-onlycurrentiMux4(T/S) Series card LFD status: 0:No 1:Yes
1.3.6.1.4.1.4756.20.430.20.1.68Columnfa4e1et100DDTOLocalread-onlycurrentiMux4(T/S) Series card DDTO status: 0:No 1:Yes
1.3.6.1.4.1.4756.20.430.20.1.69Columnfa4e1et100VcatMember1Localread-writecurrentiMux4(T/S) Series card VACT member 0: 0:Disable 1:Enable
1.3.6.1.4.1.4756.20.430.20.1.70Columnfa4e1et100VcatMember2Localread-writecurrentiMux4(T/S) Series card VACT member 1: 0:Disable 1:Enable
1.3.6.1.4.1.4756.20.430.20.1.71Columnfa4e1et100VcatMember3Localread-writecurrentiMux4(T/S) Series card VACT member 3: 0:Disable 1:Enable
1.3.6.1.4.1.4756.20.430.20.1.72Columnfa4e1et100VcatMember4Localread-writecurrentiMux4(T/S) Series card VACT member 4: 0:Disable 1:Enable
1.3.6.1.4.1.4756.20.430.20.1.73Columnfa4e1et100SnmpChannel1Localread-writecurrentiMux4(T/S) Series card SNMP channel 0: 0:No use 1:Use
1.3.6.1.4.1.4756.20.430.20.1.74Columnfa4e1et100SnmpChannel2Localread-writecurrentiMux4(T/S) Series card SNMP channel 1: 0:No use 1:Use
1.3.6.1.4.1.4756.20.430.20.1.75Columnfa4e1et100SnmpChannel3Localread-writecurrentiMux4(T/S) Series card SNMP channel 3: 0:No use 1:Use
1.3.6.1.4.1.4756.20.430.20.1.76Columnfa4e1et100SnmpChannel4Localread-writecurrentiMux4(T/S) Series card SNMP channel 4: 0:No use 1:Use
1.3.6.1.4.1.4756.20.430.20.1.77Columnfa4e1et100ErrSecLocalread-onlycurrentiMux4(T/S) Series card, errored seconds of BERT result.
1.3.6.1.4.1.4756.20.430.20.1.78Columnfa4e1et100ErrFreeSecLocalread-onlycurrentiMux4(T/S) Series card, errored free seconds of BERT result.
1.3.6.1.4.1.4756.20.430.20.1.79Columnfa4e1et100ServErrSecLocalread-onlycurrentiMux4(T/S) Series card, severely errored seconds of BERT result.
1.3.6.1.4.1.4756.20.430.20.1.80Columnfa4e1et100BertFunctionLocalread-writecurrentiMux4(T/S) Series card bert function: 0:Disable 1:Enable
1.3.6.1.4.1.4756.20.430.20.1.81Columnfa4e1et100ClrBertDataLocalread-writecurrentiMux4(T/S) Series card bert data clear: 0:Normal 1:Clear
1.3.6.1.4.1.4756.20.430.20.1.82Columnfa4e1et100BertE1ChannelLocalread-writecurrentiMux4(T/S) Series card bert E1 channel number: 0:E1 channel 1 1:E1 channel 2 2:E1 channel 3 3:E1 channel 4
1.3.6.1.4.1.4756.20.430.20.1.83Columnfa4e1et100RmonFunctionLocalread-writecurrentiMux4(T/S) Series RMON function : 0:Disable 1:Enable
1.3.6.1.4.1.4756.20.430.20.1.84Columnfa4e1et100RmonTxLocalread-onlycurrentiMux4(T/S) Series card RMON Tx counter.
1.3.6.1.4.1.4756.20.430.20.1.85Columnfa4e1et100RmonRxLocalread-onlycurrentiMux4(T/S) Series card RMON Rx counter.
1.3.6.1.4.1.4756.20.430.20.1.86Columnfa4e1et100ClrRmonTxLocalread-writecurrentiMux4(T/S) Series card clear RMON Tx counter: 0:Normal 1:Clear
1.3.6.1.4.1.4756.20.430.20.1.87Columnfa4e1et100ClrRmonRxLocalread-writecurrentiMux4(T/S) Series card clear RMON Rx counter: 0:Normal 1:Clear
1.3.6.1.4.1.4756.20.430.20.1.88Columnfa4e1et100SfpLocalread-onlycurrentiMux4(T/S) Series card, SFP existed: 0:No 1:Yes
1.3.6.1.4.1.4756.20.430.20.1.89Columnfa4e1et100SfpVendorLocalread-onlycurrentiMux4(T/S) Series card, Vendor name of SFP.
1.3.6.1.4.1.4756.20.430.20.1.90Columnfa4e1et100SfpPartNoLocalread-onlycurrentiMux4(T/S) Series card, Vendor part number of SFP.
1.3.6.1.4.1.4756.20.430.20.1.91Columnfa4e1et100SfpFiberTypeLocalread-onlycurrentiMux4(T/S) Series card, Fiber Type of SFP.
1.3.6.1.4.1.4756.20.430.20.1.92Columnfa4e1et100SfpTxWaveLenLocalread-onlycurrentiMux4(T/S) Series card, Tx Wave length of SFP.
1.3.6.1.4.1.4756.20.430.20.1.93Columnfa4e1et100SfpRxWaveLenLocalread-onlycurrentiMux4(T/S) Series card, Rx Wave length of SFP.
1.3.6.1.4.1.4756.20.430.20.1.94Columnfa4e1et100SfpLinkLenLocalread-onlycurrentiMux4(T/S) Series card, Link length of SFP.
1.3.6.1.4.1.4756.20.430.20.1.95Columnfa4e1et100SfpModelIDLocalread-onlycurrentiMux4(T/S) Series card, model ID of SFP.
1.3.6.1.4.1.4756.20.430.20.1.96Columnfa4e1et100SfpVersionLocalread-onlycurrentiMux4(T/S) Series card, the version of SFP.
1.3.6.1.4.1.4756.20.430.20.1.97Columnfa4e1et100SfpModelTypeLocalread-onlycurrentiMux4(T/S) Series card, model type of SFP.
1.3.6.1.4.1.4756.20.430.20.1.98Columnfa4e1et100DDInformationLocalread-onlycurrentiMux4(T/S) Series card, D/D information of SFP Supported: 0:No, 1:Yes
1.3.6.1.4.1.4756.20.430.20.1.99Columnfa4e1et100DDRxSensLocalread-onlycurrentiMux4(T/S) Series card, Sensitivity of D/D information.
1.3.6.1.4.1.4756.20.430.20.1.100Columnfa4e1et100DDTxPowerLocalread-onlycurrentiMux4(T/S) Series card, Tx power of D/D information.
1.3.6.1.4.1.4756.20.430.20.1.101Columnfa4e1et100DDRxPowerLocalread-onlycurrentiMux4(T/S) Series card, Rx power of D/D information.
1.3.6.1.4.1.4756.20.430.20.1.102Columnfa4e1et100DDTempLocalread-onlycurrentiMux4(T/S) Series card, Temperature of D/D information in degree C.
1.3.6.1.4.1.4756.20.430.20.1.103Columnfa4e1et100DDBiasLocalread-onlycurrentiMux4(T/S) Series card, BIAS of D/D information.
1.3.6.1.4.1.4756.20.430.20.1.104Columnfa4e1et100DDVoltageLocalread-onlycurrentiMux4(T/S) Series card, Voltage of D/D information.
1.3.6.1.4.1.4756.20.430.20.1.105Columnfa4e1et100ChannelDefectLocalread-writecurrentiMux4(T/S) Series card Channel Defect: 0:Disable 4:1E-4 6:1E-6
1.3.6.1.4.1.4756.20.430.20.1.106Columnfa4e1et100LoopDetectionLocalread-writecurrentiMux4(T/S) Series card Loop Detection: 0:Disable 1:Enable
1.3.6.1.4.1.4756.20.430.20.1.107Columnfa4e1et100LoopCh1Localread-onlycurrentiMux4(T/S) Series card E1 channel 1 Loop Check State: 0:No 1:Yes
1.3.6.1.4.1.4756.20.430.20.1.108Columnfa4e1et100LoopCh2Localread-onlycurrentiMux4(T/S) Series card E1 channel 2 Loop Check State: 0:No 1:Yes
1.3.6.1.4.1.4756.20.430.20.1.109Columnfa4e1et100LoopCh3Localread-onlycurrentiMux4(T/S) Series card E1 channel 3 Loop Check State: 0:No 1:Yes
1.3.6.1.4.1.4756.20.430.20.1.110Columnfa4e1et100LoopCh4Localread-onlycurrentiMux4(T/S) Series card E1 channel 4 Loop Check State: 0:No 1:Yes
1.3.6.1.4.1.4756.20.430.20.1.111Columnfa4e1et100DefectCh1Localread-onlycurrentiMux4(T/S) Series card E1 channel 1 Defect Status: 0:No 1:Yes
1.3.6.1.4.1.4756.20.430.20.1.112Columnfa4e1et100DefectCh2Localread-onlycurrentiMux4(T/S) Series card E1 channel 2 Defect Status: 0:No 1:Yes
1.3.6.1.4.1.4756.20.430.20.1.113Columnfa4e1et100DefectCh3Localread-onlycurrentiMux4(T/S) Series card E1 channel 3 Defect Status: 0:No 1:Yes
1.3.6.1.4.1.4756.20.430.20.1.114Columnfa4e1et100DefectCh4Localread-onlycurrentiMux4(T/S) Series card E1 channel 4 Defect Status: 0:No 1:Yes
1.3.6.1.4.1.4756.20.430.20.1.115Columnfa4e1et100FxSignalLocalread-onlycurrentiMux4(T/S) Series card Fiber signal detect(SD): 0:Fiber unplugged 1:Signal detected
1.3.6.1.4.1.4756.20.430.20.1.116Columnfa4e1et100PortResetLocalread-writecurrentiMux4(T/S) Series card Port Reset: 0:Off 1:Action
1.3.6.1.4.1.4756.20.430.20.1.117Columnfa4e1et100VLANModeLocalread-writecurrentiMux4(T/S) Series card VLAN mode: 0:MODE2 1:MODE1
1.3.6.1.4.1.4756.20.430.20.1.118Columnfa4e1et100ETagSelectEntryLocalread-writecurrentiMux4(T/S) Series card ETag select entry:
1.3.6.1.4.1.4756.20.430.20.1.119Columnfa4e1et100ETagMethodLocalread-writecurrentiMux4(T/S) Series card ETag Method: 0: Intouch 1: Add Tag 2: Remove Tag
1.3.6.1.4.1.4756.20.430.20.1.120Columnfa4e1et100VLANTableVID1Localread-writecurrentiMux4(T/S) Series card VLAN Table: VLAN ID1
1.3.6.1.4.1.4756.20.430.20.1.121Columnfa4e1et100VLANTableVID2Localread-writecurrentiMux4(T/S) Series card VLAN Table: VLAN ID2
1.3.6.1.4.1.4756.20.430.20.1.122Columnfa4e1et100VLANTableVID3Localread-writecurrentiMux4(T/S) Series card VLAN Table: VLAN ID3
1.3.6.1.4.1.4756.20.430.20.1.123Columnfa4e1et100VLANTableVID4Localread-writecurrentiMux4(T/S) Series card VLAN Table: VLAN ID4
1.3.6.1.4.1.4756.20.430.20.1.124Columnfa4e1et100VLANTableVID5Localread-writecurrentiMux4(T/S) Series card VLAN Table: VLAN ID5
1.3.6.1.4.1.4756.20.430.20.1.125Columnfa4e1et100VLANTableVID6Localread-writecurrentiMux4(T/S) Series card VLAN Table: VLAN ID6
1.3.6.1.4.1.4756.20.430.20.1.126Columnfa4e1et100VLANTableVID7Localread-writecurrentiMux4(T/S) Series card VLAN Table: VLAN ID7
1.3.6.1.4.1.4756.20.430.20.1.127Columnfa4e1et100VLANTableVID8Localread-writecurrentiMux4(T/S) Series card VLAN Table: VLAN ID8
1.3.6.1.4.1.4756.20.430.20.1.128Columnfa4e1et100VLANTableVID9Localread-writecurrentiMux4(T/S) Series card VLAN Table: VLAN ID9
1.3.6.1.4.1.4756.20.430.20.1.129Columnfa4e1et100VLANTableVID10Localread-writecurrentiMux4(T/S) Series card VLAN Table: VLAN ID10
1.3.6.1.4.1.4756.20.430.20.1.130Columnfa4e1et100VLANTableVID11Localread-writecurrentiMux4(T/S) Series card VLAN Table: VLAN ID11
1.3.6.1.4.1.4756.20.430.20.1.131Columnfa4e1et100VLANTableVID12Localread-writecurrentiMux4(T/S) Series card VLAN Table: VLAN ID12
1.3.6.1.4.1.4756.20.430.20.1.132Columnfa4e1et100VLANTableVID13Localread-writecurrentiMux4(T/S) Series card VLAN Table: VLAN ID13
1.3.6.1.4.1.4756.20.430.20.1.133Columnfa4e1et100VLANTableVID14Localread-writecurrentiMux4(T/S) Series card VLAN Table: VLAN ID14
1.3.6.1.4.1.4756.20.430.20.1.134Columnfa4e1et100VLANTableVID15Localread-writecurrentiMux4(T/S) Series card VLAN Table: VLAN ID15
1.3.6.1.4.1.4756.20.430.20.1.135Columnfa4e1et100VLANTableVID16Localread-writecurrentiMux4(T/S) Series card VLAN Table: VLAN ID16
1.3.6.1.4.1.4756.20.431Nodef4E1RemoteCards
1.3.6.1.4.1.4756.20.431.20Tablef4E1RemoteTablenot-accessiblecurrentA list of Remote FRM220A-iMux4 series card entries. The number of entries is f5E1-No-L.
1.3.6.1.4.1.4756.20.431.20.1Rowf4E1RemoteEntrynot-accessiblecurrentAn entry containing management information applicable to a particular Remote FRM220A-iMux4 series card.
1.3.6.1.4.1.4756.20.431.20.1.1Columnfa4e1et100ChassisIndexRemoteread-onlycurrentA unique value for each card. It starts from 0 to 9 contiguously.
1.3.6.1.4.1.4756.20.431.20.1.2Columnfa4e1et100SlotIndexRemoteread-onlycurrentA unique value for each card. It starts from 1 to 20 contiguously.
1.3.6.1.4.1.4756.20.431.20.1.3Columnfa4e1et100CardHWVerRemoteread-onlycurrentiMux4(T/S) Series card hardware version x.xxx
1.3.6.1.4.1.4756.20.431.20.1.4Columnfa4e1et100CardFWVerRemoteread-onlycurrentiMux4(T/S) Series card firmware version x.xxx
1.3.6.1.4.1.4756.20.431.20.1.5Columnfa4e1et100CardCPLDVerRemoteread-onlycurrentiMux4(T/S) Series card CPLD version x.xxx
1.3.6.1.4.1.4756.20.431.20.1.6Columnfa4e1et100CardFPGAVerRemoteread-onlycurrentiMux4(T/S) Series card FPGA version x.xxx
1.3.6.1.4.1.4756.20.431.20.1.7Columnfa4e1et100ModelRemoteread-onlycurrentCard Type: 0:iMux4T 1:iMux4S
1.3.6.1.4.1.4756.20.431.20.1.8Columnfa4e1et100SystemStatusRemoteread-onlycurrentiMux4(T/S) Series card system status: 0:Normal 1:Alarm
1.3.6.1.4.1.4756.20.431.20.1.9Columnfa4e1et100DeviceActiveRemoteread-onlycurrentiMux4(T/S) Series card active: 0:Disable 1:Enable
1.3.6.1.4.1.4756.20.431.20.1.10Columnfa4e1et100SetToDefaultRemoteread-writecurrentiMux4(T/S) Series card port set to default: 0:Off 1:Trigger
1.3.6.1.4.1.4756.20.431.20.1.11Columnfa4e1et100E1Ch1SingalRemoteread-onlycurrentiMux4(T/S) Series card E1 channel 1 signal status: 0:Singal Loss 1:Normal
1.3.6.1.4.1.4756.20.431.20.1.12Columnfa4e1et100E1Ch2SingalRemoteread-onlycurrentiMux4(T/S) Series card E1 channel 2 signal status: 0:Singal Loss 1:Normal
1.3.6.1.4.1.4756.20.431.20.1.13Columnfa4e1et100E1Ch3SingalRemoteread-onlycurrentiMux4(T/S) Series card E1 channel 3 signal status: 0:Singal Loss 1:Normal
1.3.6.1.4.1.4756.20.431.20.1.14Columnfa4e1et100E1Ch4SingalRemoteread-onlycurrentiMux4(T/S) Series card E1 channel 4 signal status: 0:Singal Loss 1:Normal
1.3.6.1.4.1.4756.20.431.20.1.15Columnfa4e1et100E1Ch1SyncRemoteread-onlycurrentiMux4(T/S) Series card E1 channel 1 sync status: 0:Sync Loss 1:Sync
1.3.6.1.4.1.4756.20.431.20.1.16Columnfa4e1et100E1Ch2SyncRemoteread-onlycurrentiMux4(T/S) Series card E1 channel 2 sync status: 0:Sync Loss 1:Sync
1.3.6.1.4.1.4756.20.431.20.1.17Columnfa4e1et100E1Ch3SyncRemoteread-onlycurrentiMux4(T/S) Series card E1 channel 3 sync status: 0:Sync Loss 1:Sync
1.3.6.1.4.1.4756.20.431.20.1.18Columnfa4e1et100E1Ch4SyncRemoteread-onlycurrentiMux4(T/S) Series card E1 channel 4 sync status: 0:Sync Loss 1:Sync
1.3.6.1.4.1.4756.20.431.20.1.19Columnfa4e1et100E1Ch1RecvAISRemoteread-onlycurrentiMux4(T/S) Series card E1 channel 1 receive AIS status: 0:No 1:Yes
1.3.6.1.4.1.4756.20.431.20.1.20Columnfa4e1et100E1Ch2RecvAISRemoteread-onlycurrentiMux4(T/S) Series card E1 channel 2 receive AIS status: 0:No 1:Yes
1.3.6.1.4.1.4756.20.431.20.1.21Columnfa4e1et100E1Ch3RecvAISRemoteread-onlycurrentiMux4(T/S) Series card E1 channel 3 receive AIS status: 0:No 1:Yes
1.3.6.1.4.1.4756.20.431.20.1.22Columnfa4e1et100E1Ch4RecvAISRemoteread-onlycurrentiMux4(T/S) Series card E1 channel 4 receive AIS status: 0:No 1:Yes
1.3.6.1.4.1.4756.20.431.20.1.23Columnfa4e1et100E1Ch1ConnTypeRemoteread-onlycurrentiMux4(T/S) Series card E1 channel 1 connector type: 0:RJ-48C 1:BNC
1.3.6.1.4.1.4756.20.431.20.1.24Columnfa4e1et100E1Ch2ConnTypeRemoteread-onlycurrentiMux4(T/S) Series card E1 channel 2 connector type: 0:RJ-48C 1:BNC
1.3.6.1.4.1.4756.20.431.20.1.25Columnfa4e1et100E1Ch3ConnTypeRemoteread-onlycurrentiMux4(T/S) Series card E1 channel 3 connector type: 0:RJ-48C 1:BNC
1.3.6.1.4.1.4756.20.431.20.1.26Columnfa4e1et100E1Ch4ConnTypeRemoteread-onlycurrentiMux4(T/S) Series card E1 channel 4 connector type: 0:RJ-48C 1:BNC
1.3.6.1.4.1.4756.20.431.20.1.27Columnfa4e1et100E1Ch1RAIRemoteread-onlycurrentiMux4(T/S) Series card E1 channel 1 RAI status: 0:No 1:Yes
1.3.6.1.4.1.4756.20.431.20.1.28Columnfa4e1et100E1Ch2RAIRemoteread-onlycurrentiMux4(T/S) Series card E1 channel 2 RAI status: 0:No 1:Yes
1.3.6.1.4.1.4756.20.431.20.1.29Columnfa4e1et100E1Ch3RAIRemoteread-onlycurrentiMux4(T/S) Series card E1 channel 3 RAI status: 0:No 1:Yes
1.3.6.1.4.1.4756.20.431.20.1.30Columnfa4e1et100E1Ch4RAIRemoteread-onlycurrentiMux4(T/S) Series card E1 channel 4 RAI status: 0:No 1:Yes
1.3.6.1.4.1.4756.20.431.20.1.31Columnfa4e1et100E1Ch1LOMFRemoteread-onlycurrentiMux4(T/S) Series card E1 channel 1 LOMF status: 0:No 1:Yes
1.3.6.1.4.1.4756.20.431.20.1.32Columnfa4e1et100E1Ch2LOMFRemoteread-onlycurrentiMux4(T/S) Series card E1 channel 2 LOMF status: 0:No 1:Yes
1.3.6.1.4.1.4756.20.431.20.1.33Columnfa4e1et100E1Ch3LOMFRemoteread-onlycurrentiMux4(T/S) Series card E1 channel 3 LOMF status: 0:No 1:Yes
1.3.6.1.4.1.4756.20.431.20.1.34Columnfa4e1et100E1Ch4LOMFRemoteread-onlycurrentiMux4(T/S) Series card E1 channel 4 LOMF status: 0:No 1:Yes
1.3.6.1.4.1.4756.20.431.20.1.35Columnfa4e1et100E1Ch1ActiveRemoteread-onlycurrentiMux4(T/S) Series card E1 channel 1 active status: 0:Inactive 1:Active
1.3.6.1.4.1.4756.20.431.20.1.36Columnfa4e1et100E1Ch2ActiveRemoteread-onlycurrentiMux4(T/S) Series card E1 channel 2 active status: 0:Inactive 1:Active
1.3.6.1.4.1.4756.20.431.20.1.37Columnfa4e1et100E1Ch3ActiveRemoteread-onlycurrentiMux4(T/S) Series card E1 channel 3 active status: 0:Inactive 1:Active
1.3.6.1.4.1.4756.20.431.20.1.38Columnfa4e1et100E1Ch4ActiveRemoteread-onlycurrentiMux4(T/S) Series card E1 channel 4 active status: 0:Inactive 1:Active
1.3.6.1.4.1.4756.20.431.20.1.39Columnfa4e1et100E1Ch1LoopBackRemoteread-writecurrentiMux4(T/S) Series card port E1 channel 1 loop back: 0:Off 2:RLB (Max used 3 channels)
1.3.6.1.4.1.4756.20.431.20.1.40Columnfa4e1et100E1Ch2LoopBackRemoteread-writecurrentiMux4(T/S) Series card port E1 channel 2 loop back: 0:Off 2:RLB (Max used 3 channels)
1.3.6.1.4.1.4756.20.431.20.1.41Columnfa4e1et100E1Ch3LoopBackRemoteread-writecurrentiMux4(T/S) Series card port E1 channel 3 loop back: 0:Off 2:RLB (Max used 3 channels)
1.3.6.1.4.1.4756.20.431.20.1.42Columnfa4e1et100E1Ch4LoopBackRemoteread-writecurrentiMux4(T/S) Series card port E1 channel 4 loop back: 0:Off 2:RLB (Max used 3 channels)
1.3.6.1.4.1.4756.20.431.20.1.43Columnfa4e1et100FxLinkRemoteread-onlycurrent5E1-ET100S Series card Fiber siganl detect status: 0:Down or Fiber unplugged 1:Up or Singal detected
1.3.6.1.4.1.4756.20.431.20.1.44Columnfa4e1et100FxLaserRemoteread-onlycurrent5E1-ET100S Series card laser status: 0:Normal 1:Error
1.3.6.1.4.1.4756.20.431.20.1.45Columnfa4e1et100FxActiveRemoteread-writecurrent5E1-ET100S Series card Fiber active: 0:Inactive 1:Active
1.3.6.1.4.1.4756.20.431.20.1.46Columnfa4e1et100FxLaserOutputRemoteread-writecurrent5E1-ET100S Series card laser output: 0:disable 1:Enable
1.3.6.1.4.1.4756.20.431.20.1.47Columnfa4e1et100FxOpModeRemoteread-writecurrent5E1-ET100S Series card operation mode: 0:Switch 1:Convert
1.3.6.1.4.1.4756.20.431.20.1.48Columnfa4e1et100UtpLinkRemoteread-onlycurrent5E1-ET100T Series card UTP link status: 0:Link Down 1:Link Up
1.3.6.1.4.1.4756.20.431.20.1.49Columnfa4e1et100UtpStatusRemoteread-onlycurrent5E1-ET100T Series card UTP link mode status: 0:None, Maybe link down 1:Link at 10Mbps, Half duplex 2:Link at 10Mbps, Full duplex 3:Link at 100Mbps, Half duplex…
1.3.6.1.4.1.4756.20.431.20.1.50Columnfa4e1et100UtpFlowCtrlStsRemoteread-onlycurrent5E1-ET100T Series card UTP flow control status: 0:Disable 1:Enable
1.3.6.1.4.1.4756.20.431.20.1.51Columnfa4e1et100UtpModeRemoteread-writecurrent5E1-ET100T Series card UTP mode: 0:Disable 1:Enable and autoNegotiation 3:Enable and force to 10Mbps, Half duplex 4:Enable and force to 10Mbps, Full duplex 5:E…
1.3.6.1.4.1.4756.20.431.20.1.52Columnfa4e1et100UtpFlowCtrlRemoteread-writecurrent5E1-ET100T Series card UTP flow control: 0:Disable 1:Enable
1.3.6.1.4.1.4756.20.431.20.1.53Columnfa4e1et100SpeedLimitRemoteread-writecurrentiMux4(T/S) Series card speed limit: Limited = this value * 32Kbps, this value is restricted to 0 ~ 3125, 0 to disable
1.3.6.1.4.1.4756.20.431.20.1.54Columnfa4e1et100VlanAwareRemoteread-writecurrentiMux4(T/S) Series card 802.1q VLAN tag aware: 0:Disable 1:Enable
1.3.6.1.4.1.4756.20.431.20.1.55Columnfa4e1et100VlanIDRemoteread-writecurrentiMux4(T/S) Series card VLAN ID: The ID is restricted to 1 ~ 4094
1.3.6.1.4.1.4756.20.431.20.1.56Columnfa4e1et100RemoteDeviceRemoteread-onlycurrentFRM220A-5E1 Series card remote device status: 0:Link Down 1:Link Up
1.3.6.1.4.1.4756.20.431.20.1.57Columnfa4e1et100RemotePowerRemoteread-onlycurrentiMux4(T/S) Series card remote device power status: 0:Normal 1:Power off
1.3.6.1.4.1.4756.20.431.20.1.58Columnfa4e1et100TimingSourceRemoteread-writecurrentiMux4(T/S) Series card clock: 0:Internal oscillatro 1:Recovery from E1 channel 1 2:Recovery from E1 channel 2 3:Recovery from E1 channel 3 4:Recovery from E1 c…
1.3.6.1.4.1.4756.20.431.20.1.59Columnfa4e1et100FCSofGFPRemoteread-writecurrentiMux4(T/S) Series card FCS of GFP: 0:Disable 1:Enable
1.3.6.1.4.1.4756.20.431.20.1.60Columnfa4e1et100AutoChAdjustRemoteread-writecurrentiMux4(T/S) Series card auto channel Bdjust: 0:Disable 1:Enable
1.3.6.1.4.1.4756.20.431.20.1.61Columnfa4e1et100PayloadScrambleRemoteread-writecurrentiMux4(T/S) Series card payload scramble: 0:Disable 1:Enable
1.3.6.1.4.1.4756.20.431.20.1.62Columnfa4e1et100FailoverRemoteread-writecurrentiMux4(T/S) Series card failover: 0:Disable 1:Enable
1.3.6.1.4.1.4756.20.431.20.1.63Columnfa4e1et100LOMRemoteread-onlycurrentiMux4(T/S) Series card LOM status: 0:No 1:Yes
1.3.6.1.4.1.4756.20.431.20.1.64Columnfa4e1et100SQMRemoteread-onlycurrentiMux4(T/S) Series card SQM status: 0:No 1:Yes
1.3.6.1.4.1.4756.20.431.20.1.65Columnfa4e1et100CRCRemoteread-onlycurrentiMux4(T/S) Series card CRC status: 0:No 1:Yes
1.3.6.1.4.1.4756.20.431.20.1.66Columnfa4e1et100LOARemoteread-onlycurrentiMux4(T/S) Series card LOA status: 0:No 1:Yes
1.3.6.1.4.1.4756.20.431.20.1.67Columnfa4e1et100LFDRemoteread-onlycurrentiMux4(T/S) Series card LFD status: 0:No 1:Yes
1.3.6.1.4.1.4756.20.431.20.1.68Columnfa4e1et100DDTORemoteread-onlycurrentiMux4(T/S) Series card DDTO status: 0:No 1:Yes
1.3.6.1.4.1.4756.20.431.20.1.69Columnfa4e1et100VcatMember1Remoteread-writecurrentiMux4(T/S) Series card VACT member 0: 0:Disable 1:Enable
1.3.6.1.4.1.4756.20.431.20.1.70Columnfa4e1et100VcatMember2Remoteread-writecurrentiMux4(T/S) Series card VACT member 1: 0:Disable 1:Enable
1.3.6.1.4.1.4756.20.431.20.1.71Columnfa4e1et100VcatMember3Remoteread-writecurrentiMux4(T/S) Series card VACT member 3: 0:Disable 1:Enable
1.3.6.1.4.1.4756.20.431.20.1.72Columnfa4e1et100VcatMember4Remoteread-writecurrentiMux4(T/S) Series card VACT member 4: 0:Disable 1:Enable
1.3.6.1.4.1.4756.20.431.20.1.73Columnfa4e1et100SnmpChannel1Remoteread-writecurrentiMux4(T/S) Series card SNMP channel 0: 0:No use 1:Use
1.3.6.1.4.1.4756.20.431.20.1.74Columnfa4e1et100SnmpChannel2Remoteread-writecurrentiMux4(T/S) Series card SNMP channel 1: 0:No use 1:Use
1.3.6.1.4.1.4756.20.431.20.1.75Columnfa4e1et100SnmpChannel3Remoteread-writecurrentiMux4(T/S) Series card SNMP channel 3: 0:No use 1:Use
1.3.6.1.4.1.4756.20.431.20.1.76Columnfa4e1et100SnmpChannel4Remoteread-writecurrentiMux4(T/S) Series card SNMP channel 4: 0:No use 1:Use
1.3.6.1.4.1.4756.20.431.20.1.77Columnfa4e1et100ErrSecRemoteread-onlycurrentiMux4(T/S) Series card, errored seconds of BERT result.
1.3.6.1.4.1.4756.20.431.20.1.78Columnfa4e1et100ErrFreeSecRemoteread-onlycurrentiMux4(T/S) Series card, errored free seconds of BERT result.
1.3.6.1.4.1.4756.20.431.20.1.79Columnfa4e1et100ServErrSecRemoteread-onlycurrentiMux4(T/S) Series card, severely errored seconds of BERT result.
1.3.6.1.4.1.4756.20.431.20.1.80Columnfa4e1et100BertFunctionRemoteread-writecurrentiMux4(T/S) Series card bert function: 0:Disable 1:Enable
1.3.6.1.4.1.4756.20.431.20.1.81Columnfa4e1et100ClrBertDataRemoteread-writecurrentiMux4(T/S) Series card bert data clear: 0:Normal 1:Clear
1.3.6.1.4.1.4756.20.431.20.1.82Columnfa4e1et100BertE1ChannelRemoteread-writecurrentiMux4(T/S) Series card bert E1 channel number: 0:E1 channel 1 1:E1 channel 2 2:E1 channel 3 3:E1 channel 4
1.3.6.1.4.1.4756.20.431.20.1.83Columnfa4e1et100RmonFunctionRemoteread-writecurrentiMux4(T/S) Series RMON function : 0:Disable 1:Enable
1.3.6.1.4.1.4756.20.431.20.1.84Columnfa4e1et100RmonTxRemoteread-onlycurrentiMux4(T/S) Series card RMON Tx counter.
1.3.6.1.4.1.4756.20.431.20.1.85Columnfa4e1et100RmonRxRemoteread-onlycurrentiMux4(T/S) Series card RMON Rx counter.
1.3.6.1.4.1.4756.20.431.20.1.86Columnfa4e1et100ClrRmonTxRemoteread-writecurrentiMux4(T/S) Series card clear RMON Tx counter: 0:Normal 1:Clear
1.3.6.1.4.1.4756.20.431.20.1.87Columnfa4e1et100ClrRmonRxRemoteread-writecurrentiMux4(T/S) Series card clear RMON Rx counter: 0:Normal 1:Clear
1.3.6.1.4.1.4756.20.431.20.1.88Columnfa4e1et100SfpRemoteread-onlycurrentiMux4(T/S) Series card, SFP existed: 0:No 1:Yes
1.3.6.1.4.1.4756.20.431.20.1.89Columnfa4e1et100SfpVendorRemoteread-onlycurrentiMux4(T/S) Series card, Vendor name of SFP.
1.3.6.1.4.1.4756.20.431.20.1.90Columnfa4e1et100SfpPartNoRemoteread-onlycurrentiMux4(T/S) Series card, Vendor part number of SFP.
1.3.6.1.4.1.4756.20.431.20.1.91Columnfa4e1et100SfpFiberTypeRemoteread-onlycurrentiMux4(T/S) Series card, Fiber Type of SFP.
1.3.6.1.4.1.4756.20.431.20.1.92Columnfa4e1et100SfpTxWaveLenRemoteread-onlycurrentiMux4(T/S) Series card, Tx Wave length of SFP.
1.3.6.1.4.1.4756.20.431.20.1.93Columnfa4e1et100SfpRxWaveLenRemoteread-onlycurrentiMux4(T/S) Series card, Rx Wave length of SFP.
1.3.6.1.4.1.4756.20.431.20.1.94Columnfa4e1et100SfpLinkLenRemoteread-onlycurrentiMux4(T/S) Series card, Link length of SFP.
1.3.6.1.4.1.4756.20.431.20.1.95Columnfa4e1et100SfpModelIDRemoteread-onlycurrentiMux4(T/S) Series card, model ID of SFP.
1.3.6.1.4.1.4756.20.431.20.1.96Columnfa4e1et100SfpVersionRemoteread-onlycurrentiMux4(T/S) Series card, the version of SFP.
1.3.6.1.4.1.4756.20.431.20.1.97Columnfa4e1et100SfpModelTypeRemoteread-onlycurrentiMux4(T/S) Series card, model type of SFP.
1.3.6.1.4.1.4756.20.431.20.1.98Columnfa4e1et100DDInformationRemoteread-onlycurrentiMux4(T/S) Series card, D/D information of SFP Supported: 0:No, 1:Yes
1.3.6.1.4.1.4756.20.431.20.1.99Columnfa4e1et100DDRxSensRemoteread-onlycurrentiMux4(T/S) Series card, Sensitivity of D/D information.
1.3.6.1.4.1.4756.20.431.20.1.100Columnfa4e1et100DDTxPowerRemoteread-onlycurrentiMux4(T/S) Series card, Tx power of D/D information.
1.3.6.1.4.1.4756.20.431.20.1.101Columnfa4e1et100DDRxPowerRemoteread-onlycurrentiMux4(T/S) Series card, Rx power of D/D information.
1.3.6.1.4.1.4756.20.431.20.1.102Columnfa4e1et100DDTempRemoteread-onlycurrentiMux4(T/S) Series card, Temperature of D/D information in degree C.
1.3.6.1.4.1.4756.20.431.20.1.103Columnfa4e1et100DDBiasRemoteread-onlycurrentiMux4(T/S) Series card, BIAS of D/D information.
1.3.6.1.4.1.4756.20.431.20.1.104Columnfa4e1et100DDVoltageRemoteread-onlycurrentiMux4(T/S) Series card, Voltage of D/D information.
1.3.6.1.4.1.4756.20.431.20.1.105Columnfa4e1et100ChannelDefectRemoteread-writecurrentiMux4(T/S) Series card Channel Defect: 0:Disable 4:1E-4 6:1E-6
1.3.6.1.4.1.4756.20.431.20.1.106Columnfa4e1et100LoopDetectionRemoteread-writecurrentiMux4(T/S) Series card Loop Detection: 0:Disable 1:Enable
1.3.6.1.4.1.4756.20.431.20.1.107Columnfa4e1et100LoopCh1Remoteread-onlycurrentiMux4(T/S) Series card E1 channel 1 Loop Check State: 0:No 1:Yes
1.3.6.1.4.1.4756.20.431.20.1.108Columnfa4e1et100LoopCh2Remoteread-onlycurrentiMux4(T/S) Series card E1 channel 2 Loop Check State: 0:No 1:Yes
1.3.6.1.4.1.4756.20.431.20.1.109Columnfa4e1et100LoopCh3Remoteread-onlycurrentiMux4(T/S) Series card E1 channel 3 Loop Check State: 0:No 1:Yes
1.3.6.1.4.1.4756.20.431.20.1.110Columnfa4e1et100LoopCh4Remoteread-onlycurrentiMux4(T/S) Series card E1 channel 4 Loop Check State: 0:No 1:Yes
1.3.6.1.4.1.4756.20.431.20.1.111Columnfa4e1et100DefectCh1Remoteread-onlycurrentiMux4(T/S) Series card E1 channel 1 Defect Status: 0:No 1:Yes
1.3.6.1.4.1.4756.20.431.20.1.112Columnfa4e1et100DefectCh2Remoteread-onlycurrentiMux4(T/S) Series card E1 channel 2 Defect Status: 0:No 1:Yes
1.3.6.1.4.1.4756.20.431.20.1.113Columnfa4e1et100DefectCh3Remoteread-onlycurrentiMux4(T/S) Series card E1 channel 3 Defect Status: 0:No 1:Yes
1.3.6.1.4.1.4756.20.431.20.1.114Columnfa4e1et100DefectCh4Remoteread-onlycurrentiMux4(T/S) Series card E1 channel 4 Defect Status: 0:No 1:Yes
1.3.6.1.4.1.4756.20.431.20.1.115Columnfa4e1et100FxSignalRemoteread-onlycurrentiMux4(T/S) Series card Fiber signal detect(SD): 0:Fiber unplugged 1:Signal detected
1.3.6.1.4.1.4756.20.431.20.1.116Columnfa4e1et100PortResetRemoteread-writecurrentiMux4(T/S) Series card Port Reset: 0:Off 1:Action
1.3.6.1.4.1.4756.20.431.20.1.117Columnfa4e1et100VLANModeRemoteread-writecurrentiMux4(T/S) Series card VLAN mode: 0:MODE2 1:MODE1
1.3.6.1.4.1.4756.20.431.20.1.118Columnfa4e1et100ETagSelectEntryRemoteread-writecurrentiMux4(T/S) Series card ETag select entry:
1.3.6.1.4.1.4756.20.431.20.1.119Columnfa4e1et100ETagMethodRemoteread-writecurrentiMux4(T/S) Series card ETag Method: 0: Intouch 1: Add Tag 2: Remove Tag
1.3.6.1.4.1.4756.20.431.20.1.120Columnfa4e1et100VLANTableVID1Remoteread-writecurrentiMux4(T/S) Series card VLAN Table: VLAN ID1
1.3.6.1.4.1.4756.20.431.20.1.121Columnfa4e1et100VLANTableVID2Remoteread-writecurrentiMux4(T/S) Series card VLAN Table: VLAN ID2
1.3.6.1.4.1.4756.20.431.20.1.122Columnfa4e1et100VLANTableVID3Remoteread-writecurrentiMux4(T/S) Series card VLAN Table: VLAN ID3
1.3.6.1.4.1.4756.20.431.20.1.123Columnfa4e1et100VLANTableVID4Remoteread-writecurrentiMux4(T/S) Series card VLAN Table: VLAN ID4
1.3.6.1.4.1.4756.20.431.20.1.124Columnfa4e1et100VLANTableVID5Remoteread-writecurrentiMux4(T/S) Series card VLAN Table: VLAN ID5
1.3.6.1.4.1.4756.20.431.20.1.125Columnfa4e1et100VLANTableVID6Remoteread-writecurrentiMux4(T/S) Series card VLAN Table: VLAN ID6
1.3.6.1.4.1.4756.20.431.20.1.126Columnfa4e1et100VLANTableVID7Remoteread-writecurrentiMux4(T/S) Series card VLAN Table: VLAN ID7
1.3.6.1.4.1.4756.20.431.20.1.127Columnfa4e1et100VLANTableVID8Remoteread-writecurrentiMux4(T/S) Series card VLAN Table: VLAN ID8
1.3.6.1.4.1.4756.20.431.20.1.128Columnfa4e1et100VLANTableVID9Remoteread-writecurrentiMux4(T/S) Series card VLAN Table: VLAN ID9
1.3.6.1.4.1.4756.20.431.20.1.129Columnfa4e1et100VLANTableVID10Remoteread-writecurrentiMux4(T/S) Series card VLAN Table: VLAN ID10
1.3.6.1.4.1.4756.20.431.20.1.130Columnfa4e1et100VLANTableVID11Remoteread-writecurrentiMux4(T/S) Series card VLAN Table: VLAN ID11
1.3.6.1.4.1.4756.20.431.20.1.131Columnfa4e1et100VLANTableVID12Remoteread-writecurrentiMux4(T/S) Series card VLAN Table: VLAN ID12
1.3.6.1.4.1.4756.20.431.20.1.132Columnfa4e1et100VLANTableVID13Remoteread-writecurrentiMux4(T/S) Series card VLAN Table: VLAN ID13
1.3.6.1.4.1.4756.20.431.20.1.133Columnfa4e1et100VLANTableVID14Remoteread-writecurrentiMux4(T/S) Series card VLAN Table: VLAN ID14
1.3.6.1.4.1.4756.20.431.20.1.134Columnfa4e1et100VLANTableVID15Remoteread-writecurrentiMux4(T/S) Series card VLAN Table: VLAN ID15
1.3.6.1.4.1.4756.20.431.20.1.135Columnfa4e1et100VLANTableVID16Remoteread-writecurrentiMux4(T/S) Series card VLAN Table: VLAN ID16
1.3.6.1.4.1.4756.20.440NodeeddLocalCards
1.3.6.1.4.1.4756.20.440.20TableeddLocalTablenot-accessiblecurrentA list of Local FRM220-EDD series card entries.
1.3.6.1.4.1.4756.20.440.20.1RoweddLocalEntrynot-accessiblecurrentAn entry containing management information applicable to a particular FRM220-EDD series card.
1.3.6.1.4.1.4756.20.440.20.1.1ColumneddChassisIndexLocalread-onlycurrentA unique value for each card. It starts from 0 to 9 contiguously.
1.3.6.1.4.1.4756.20.440.20.1.2ColumneddSlotIndexLocalread-onlycurrentA unique value for each card. It starts from 1 to 20 contiguously.
1.3.6.1.4.1.4756.20.440.20.1.3ColumneddCardHWVerLocalread-onlycurrentEDD Series card hardware version x.xxx
1.3.6.1.4.1.4756.20.440.20.1.4ColumneddCardFWVerLocalread-onlycurrentEDD Series card firmware version x.xxx
1.3.6.1.4.1.4756.20.440.20.1.5ColumneddCardCPLDVerLocalread-onlycurrentEDD Series card CPLD version x.xxx
1.3.6.1.4.1.4756.20.440.20.1.6ColumneddCardFPGAVerLocalread-onlycurrentEDD Series card FPGA version x.xxx
1.3.6.1.4.1.4756.20.440.20.1.7ColumneddModelLocalread-onlycurrentCard Type: 0:MX210 1:MSW202
1.3.6.1.4.1.4756.20.440.20.1.8ColumneddPort1LinkstsLocalread-onlycurrentEDD Series card Port1 link status: 0:Link down 1:Link up
1.3.6.1.4.1.4756.20.440.20.1.9ColumneddPort1SpeedstsLocalread-onlycurrentEDD Series card Port1 speed status 10Base-T 100Base-Tx 1000Base-Tx 2.5G
1.3.6.1.4.1.4756.20.440.20.1.10ColumneddPort1DuplexstsLocalread-onlycurrentEDD Series card Port1 duplex status 0: Half 1: Full
1.3.6.1.4.1.4756.20.440.20.1.11ColumneddPort1RxPausestsLocalread-onlycurrentEDD Series card Port1 rx pause status 0: No 1: Yes
1.3.6.1.4.1.4756.20.440.20.1.12ColumneddPort1TxPausestsLocalread-onlycurrentEDD Series card Port1 tx pause status 0: No 1: Yes
1.3.6.1.4.1.4756.20.440.20.1.13ColumneddPort2LinkstsLocalread-onlycurrentEDD Series card Port2 link status: 0:Link down 1:Link up
1.3.6.1.4.1.4756.20.440.20.1.14ColumneddPort2SpeedstsLocalread-onlycurrentEDD Series card Port2 speed status 10Base-T 100Base-Tx 1000Base-Tx 2.5G
1.3.6.1.4.1.4756.20.440.20.1.15ColumneddPort2DuplexstsLocalread-onlycurrentEDD Series card Port2 duplex status 0: Half 1: Full
1.3.6.1.4.1.4756.20.440.20.1.16ColumneddPort2RxPausestsLocalread-onlycurrentEDD Series card Port2 rx pause status 0: No 1: Yes
1.3.6.1.4.1.4756.20.440.20.1.17ColumneddPort2TxPausestsLocalread-onlycurrentEDD Series card Port2 tx pause status 0: No 1: Yes
1.3.6.1.4.1.4756.20.440.20.1.18ColumneddPort3LinkstsLocalread-onlycurrentEDD Series card Port3 link status: 0:Link down 1:Link up
1.3.6.1.4.1.4756.20.440.20.1.19ColumneddPort3SpeedstsLocalread-onlycurrentEDD Series card Port3 speed status 10Base-T 100Base-Tx 1000Base-Tx
1.3.6.1.4.1.4756.20.440.20.1.20ColumneddPort3DuplexstsLocalread-onlycurrentEDD Series card Port3 duplex status 0: Half 1: Full
1.3.6.1.4.1.4756.20.440.20.1.21ColumneddPort3RxPausestsLocalread-onlycurrentEDD Series card Port3 rx pause status 0: No 1: Yes
1.3.6.1.4.1.4756.20.440.20.1.22ColumneddPort3TxPausestsLocalread-onlycurrentEDD Series card Port3 tx pause status 0: No 1: Yes
1.3.6.1.4.1.4756.20.440.20.1.23ColumneddPort4LinkstsLocalread-onlycurrentEDD Series card Port4 link status: 0:Link down 1:Link up
1.3.6.1.4.1.4756.20.440.20.1.24ColumneddPort4SpeedstsLocalread-onlycurrentEDD Series card Port4 speed status 10Base-T 100Base-Tx 1000Base-Tx
1.3.6.1.4.1.4756.20.440.20.1.25ColumneddPort4DuplexstsLocalread-onlycurrentEDD Series card Port4 duplex status 0: Half 1: Full
1.3.6.1.4.1.4756.20.440.20.1.26ColumneddPort4RxPausestsLocalread-onlycurrentEDD Series card Port4 rx pause status 0: No 1: Yes
1.3.6.1.4.1.4756.20.440.20.1.27ColumneddPort4TxPausestsLocalread-onlycurrentEDD Series card Port4 tx pause status 0: No 1: Yes
1.3.6.1.4.1.4756.20.440.20.1.28ColumneddPort1SpeedConfLocalread-writecurrentEDD Series card Port1 speed config 0: disable 1: auto 2: 100M FDX 3: 1G FDX 4: 2.5G FDX
1.3.6.1.4.1.4756.20.440.20.1.29ColumneddPort1flowConrolLocalread-writecurrentEDD Series card Port1 flow control config 0: no 1: yes
1.3.6.1.4.1.4756.20.440.20.1.30ColumneddPort1MaxFrameLocalread-writecurrentEDD Series card Port1 max frame config
1.3.6.1.4.1.4756.20.440.20.1.31ColumneddPort2SpeedConfLocalread-writecurrentEDD Series card Port2 speed config 0: disable 1: auto 2: 100M FDX 3: 1G FDX 4: 2.5G FDX
1.3.6.1.4.1.4756.20.440.20.1.32ColumneddPort2flowConrolLocalread-writecurrentEDD Series card Port2 flow control config 0: no 1: yes
1.3.6.1.4.1.4756.20.440.20.1.33ColumneddPort2MaxFrameLocalread-writecurrentEDD Series card Port2 max frame config
1.3.6.1.4.1.4756.20.440.20.1.34ColumneddPort3SpeedConfLocalread-writecurrentEDD Series card Port3 speed config 0: disable 1: auto 2: 10M HDX 3: 10M FDX 4: 100M HDX 5: 100M FDX 6: 1G FDX
1.3.6.1.4.1.4756.20.440.20.1.35ColumneddPort3flowConrolLocalread-writecurrentEDD Series card Port3 flow control config 0: no 1: yes
1.3.6.1.4.1.4756.20.440.20.1.36ColumneddPort3MaxFrameLocalread-writecurrentEDD Series card Port3 max frame config
1.3.6.1.4.1.4756.20.440.20.1.37ColumneddPort3CollisionModeLocalread-writecurrentEDD Series card Port3 collision mode config.(MSW202 only) 0: Discard 1: Restart
1.3.6.1.4.1.4756.20.440.20.1.38ColumneddPort4SpeedConfLocalread-writecurrentEDD Series card Port4 speed config 0: disable 1: auto 2: 10M HDX 3: 10M FDX 4: 100M HDX 5: 100M FDX 6: 1G FDX
1.3.6.1.4.1.4756.20.440.20.1.39ColumneddPort4flowConrolLocalread-writecurrentEDD Series card Port4 flow control config 0: no 1: yes
1.3.6.1.4.1.4756.20.440.20.1.40ColumneddPort4MaxFrameLocalread-writecurrentEDD Series card Port4 max frame config
1.3.6.1.4.1.4756.20.440.20.1.41ColumneddPort4CollisionModeLocalread-writecurrentEDD Series card Port4 collision mode config 0: Discard 1: Restart
1.3.6.1.4.1.4756.20.440.20.1.42ColumneddSaveStartupCongLocalread-writecurrentEDD Series card save start-up config 0: OFF 1: Action
1.3.6.1.4.1.4756.20.440.20.1.43ColumneddPortResetLocalread-writecurrentEDD Series card port reset 0: OFF 1: Action
1.3.6.1.4.1.4756.20.440.20.1.44ColumneddSetDefaultLocalread-writecurrentEDD Series card set to default config 0: OFF 1: Action
1.3.6.1.4.1.4756.20.440.20.1.45ColumneddMuxModeLocalread-writecurrentEDD Series card Mux mode (MX210 only) 0: Disable 1: Switch 2: Isolate 3: VLAN
1.3.6.1.4.1.4756.20.440.20.1.46ColumneddPort1PacketsRxLocalread-onlycurrentEDD Series card port1 traffic overview:: Packets Rx
1.3.6.1.4.1.4756.20.440.20.1.47ColumneddPort1PacketsTxLocalread-onlycurrentEDD Series card port1 traffic overview:: Packets Tx
1.3.6.1.4.1.4756.20.440.20.1.48ColumneddPort1BytesRxLocalread-onlycurrentEDD Series card port1 traffic overview:: Bytes Rx
1.3.6.1.4.1.4756.20.440.20.1.49ColumneddPort1BytesTxLocalread-onlycurrentEDD Series card port1 traffic overview:: Bytes Tx
1.3.6.1.4.1.4756.20.440.20.1.50ColumneddPort1ErrorsRxLocalread-onlycurrentEDD Series card port1 traffic overview:: Errors Rx
1.3.6.1.4.1.4756.20.440.20.1.51ColumneddPort1ErrorsTxLocalread-onlycurrentEDD Series card port1 traffic overview:: Errors Tx
1.3.6.1.4.1.4756.20.440.20.1.52ColumneddPort1DropsRxLocalread-onlycurrentEDD Series card port1 traffic overview:: Drops Rx
1.3.6.1.4.1.4756.20.440.20.1.53ColumneddPort1DropsTxLocalread-onlycurrentEDD Series card port1 traffic overview:: Drops Tx
1.3.6.1.4.1.4756.20.440.20.1.54ColumneddPort1FilteredRxLocalread-onlycurrentEDD Series card port1 traffic overview:: Filtered Rx
1.3.6.1.4.1.4756.20.440.20.1.55ColumneddPort2PacketsRxLocalread-onlycurrentEDD Series card port2 traffic overview:: Packets Rx
1.3.6.1.4.1.4756.20.440.20.1.56ColumneddPort2PacketsTxLocalread-onlycurrentEDD Series card port2 traffic overview:: Packets Tx
1.3.6.1.4.1.4756.20.440.20.1.57ColumneddPort2BytesRxLocalread-onlycurrentEDD Series card port2 traffic overview:: Bytes Rx
1.3.6.1.4.1.4756.20.440.20.1.58ColumneddPort2BytesTxLocalread-onlycurrentEDD Series card port2 traffic overview:: Bytes Tx
1.3.6.1.4.1.4756.20.440.20.1.59ColumneddPort2ErrorsRxLocalread-onlycurrentEDD Series card port2 traffic overview:: Errors Rx
1.3.6.1.4.1.4756.20.440.20.1.60ColumneddPort2ErrorsTxLocalread-onlycurrentEDD Series card port2 traffic overview:: Errors Tx
1.3.6.1.4.1.4756.20.440.20.1.61ColumneddPort2DropsRxLocalread-onlycurrentEDD Series card port2 traffic overview:: Drops Rx
1.3.6.1.4.1.4756.20.440.20.1.62ColumneddPort2DropsTxLocalread-onlycurrentEDD Series card port2 traffic overview:: Drops Tx
1.3.6.1.4.1.4756.20.440.20.1.63ColumneddPort2FilteredRxLocalread-onlycurrentEDD Series card port2 traffic overview:: Filtered Rx
1.3.6.1.4.1.4756.20.440.20.1.64ColumneddPort3PacketsRxLocalread-onlycurrentEDD Series card port3 traffic overview:: Packets Rx
1.3.6.1.4.1.4756.20.440.20.1.65ColumneddPort3PacketsTxLocalread-onlycurrentEDD Series card port3 traffic overview:: Packets Tx
1.3.6.1.4.1.4756.20.440.20.1.66ColumneddPort3BytesRxLocalread-onlycurrentEDD Series card port3 traffic overview:: Bytes Rx
1.3.6.1.4.1.4756.20.440.20.1.67ColumneddPort3BytesTxLocalread-onlycurrentEDD Series card port3 traffic overview:: Bytes Tx
1.3.6.1.4.1.4756.20.440.20.1.68ColumneddPort3ErrorsRxLocalread-onlycurrentEDD Series card port3 traffic overview:: Errors Rx
1.3.6.1.4.1.4756.20.440.20.1.69ColumneddPort3ErrorsTxLocalread-onlycurrentEDD Series card port3 traffic overview:: Errors Tx
1.3.6.1.4.1.4756.20.440.20.1.70ColumneddPort3DropsRxLocalread-onlycurrentEDD Series card port3 traffic overview:: Drops Rx
1.3.6.1.4.1.4756.20.440.20.1.71ColumneddPort3DropsTxLocalread-onlycurrentEDD Series card port3 traffic overview:: Drops Tx
1.3.6.1.4.1.4756.20.440.20.1.72ColumneddPort3FilteredRxLocalread-onlycurrentEDD Series card port3 traffic overview:: Filtered Rx
1.3.6.1.4.1.4756.20.440.20.1.73ColumneddPort4PacketsRxLocalread-onlycurrentEDD Series card port4 traffic overview:: Packets Rx
1.3.6.1.4.1.4756.20.440.20.1.74ColumneddPort4PacketsTxLocalread-onlycurrentEDD Series card port4 traffic overview:: Packets Tx
1.3.6.1.4.1.4756.20.440.20.1.75ColumneddPort4BytesRxLocalread-onlycurrentEDD Series card port4 traffic overview:: Bytes Rx
1.3.6.1.4.1.4756.20.440.20.1.76ColumneddPort4BytesTxLocalread-onlycurrentEDD Series card port4 traffic overview:: Bytes Tx
1.3.6.1.4.1.4756.20.440.20.1.77ColumneddPort4ErrorsRxLocalread-onlycurrentEDD Series card port4 traffic overview:: Errors Rx
1.3.6.1.4.1.4756.20.440.20.1.78ColumneddPort4ErrorsTxLocalread-onlycurrentEDD Series card port4 traffic overview:: Errors Tx
1.3.6.1.4.1.4756.20.440.20.1.79ColumneddPort4DropsRxLocalread-onlycurrentEDD Series card port4 traffic overview:: Drops Rx
1.3.6.1.4.1.4756.20.440.20.1.80ColumneddPort4DropsTxLocalread-onlycurrentEDD Series card port4 traffic overview:: Drops Tx
1.3.6.1.4.1.4756.20.440.20.1.81ColumneddPort4FilteredRxLocalread-onlycurrentEDD Series card port4 traffic overview:: Filtered Rx
1.3.6.1.4.1.4756.20.440.20.1.82ColumnedduRingInstanceAddLocalread-writecurrentEDD Series card Add a new uRing Instance. Syntax: <Instance ID> <ring|sub|chain> <port east> <port west> Instance ID must be either 1 or 2 port east , the valu…
1.3.6.1.4.1.4756.20.440.20.1.83ColumnedduRingInstanceDeleteLocalread-writecurrentEDD Series card Delete a uRing Instance. Syntax: <uRing Instance>
1.3.6.1.4.1.4756.20.440.20.1.84ColumnedduRingInst1IDLocalread-onlycurrentEDD Series card u-Ring instance1 ID
1.3.6.1.4.1.4756.20.440.20.1.85ColumnedduRingInst1typeLocalread-onlycurrentEDD Series card u-Ring instance1 type 0: u-Ring 1: Sub-Ring 2: u-Chain
1.3.6.1.4.1.4756.20.440.20.1.86ColumnedduRingInst1masterLocalread-writecurrentEDD Series card u-Ring instance1 master 0: No 1: Yes
1.3.6.1.4.1.4756.20.440.20.1.87ColumnedduRingInst1EastPortLocalread-onlycurrentEDD Series card u-Ring instance1 east port
1.3.6.1.4.1.4756.20.440.20.1.88ColumnedduRingInst1EastEdgeLocalread-writecurrentEDD Series card u-Ring instance1 east edge 0: No 1: Yes
1.3.6.1.4.1.4756.20.440.20.1.89ColumnedduRingInst1WestPortLocalread-onlycurrentEDD Series card u-Ring instance1 west port
1.3.6.1.4.1.4756.20.440.20.1.90ColumnedduRingInst1WestEdgeLocalread-writecurrentEDD Series card u-Ring instance1 west edge 0: No 1: Yes
1.3.6.1.4.1.4756.20.440.20.1.91ColumnedduRingInst2IDLocalread-onlycurrentEDD Series card u-Ring instance2 ID
1.3.6.1.4.1.4756.20.440.20.1.92ColumnedduRingInst2typeLocalread-onlycurrentEDD Series card u-Ring instance2 type 0: u-Ring 1: Sub-Ring 2: u-Chain
1.3.6.1.4.1.4756.20.440.20.1.93ColumnedduRingInst2masterLocalread-writecurrentEDD Series card u-Ring instance2 master 0: No 1: Yes
1.3.6.1.4.1.4756.20.440.20.1.94ColumnedduRingInst2EastPortLocalread-onlycurrentEDD Series card u-Ring instance2 east port
1.3.6.1.4.1.4756.20.440.20.1.95ColumnedduRingInst2EastEdgeLocalread-writecurrentEDD Series card u-Ring instance2 east edge 0: No 1: Yes
1.3.6.1.4.1.4756.20.440.20.1.96ColumnedduRingInst2WestPortLocalread-onlycurrentEDD Series card u-Ring instance2 west port
1.3.6.1.4.1.4756.20.440.20.1.97ColumnedduRingInst2WestEdgeLocalread-writecurrentEDD Series card u-Ring instance2 west edge 0: No 1: Yes
1.3.6.1.4.1.4756.20.440.20.1.98ColumnedduRingInst1IDstsLocalread-onlycurrentEDD Series card u-Ring Instance1 ID status
1.3.6.1.4.1.4756.20.440.20.1.99ColumnedduRingInst1typestsLocalread-onlycurrentEDD Series card u-Ring Type status
1.3.6.1.4.1.4756.20.440.20.1.100ColumnedduRingInst1rolestsLocalread-onlycurrentEDD Series card u-Ring Role status
1.3.6.1.4.1.4756.20.440.20.1.101ColumnedduRingInst1EastPortstsLocalread-onlycurrentEDD Series card u-Ring East port status
1.3.6.1.4.1.4756.20.440.20.1.102ColumnedduRingInst1EaststsLocalread-onlycurrentEDD Series card u-Ring East status
1.3.6.1.4.1.4756.20.440.20.1.103ColumnedduRingInst1EastEdgestsLocalread-onlycurrentEDD Series card u-Ring East edge status
1.3.6.1.4.1.4756.20.440.20.1.104ColumnedduRingInst1WestPortstsLocalread-onlycurrentEDD Series card u-Ring West edge status
1.3.6.1.4.1.4756.20.440.20.1.105ColumnedduRingInst1WeststsLocalread-onlycurrentEDD Series card u-Ring West status
1.3.6.1.4.1.4756.20.440.20.1.106ColumnedduRingInst1WestEdgestsLocalread-onlycurrentEDD Series card u-Ring West status
1.3.6.1.4.1.4756.20.440.20.1.107ColumnedduRingInst1healthystsLocalread-onlycurrentEDD Series card u-Ring healthy status None Fine Fault
1.3.6.1.4.1.4756.20.440.20.1.108ColumnedduRingInst2IDstsLocalread-onlycurrentEDD Series card u-Ring Instance2 ID status
1.3.6.1.4.1.4756.20.440.20.1.109ColumnedduRingInst2typestsLocalread-onlycurrentEDD Series card u-Ring Type status
1.3.6.1.4.1.4756.20.440.20.1.110ColumnedduRingInst2rolestsLocalread-onlycurrentEDD Series card u-Ring Role status
1.3.6.1.4.1.4756.20.440.20.1.111ColumnedduRingInst2EastPortstsLocalread-onlycurrentEDD Series card u-Ring East port status
1.3.6.1.4.1.4756.20.440.20.1.112ColumnedduRingInst2EaststsLocalread-onlycurrentEDD Series card u-Ring East status
1.3.6.1.4.1.4756.20.440.20.1.113ColumnedduRingInst2EastEdgestsLocalread-onlycurrentEDD Series card u-Ring East edge status
1.3.6.1.4.1.4756.20.440.20.1.114ColumnedduRingInst2WestPortstsLocalread-onlycurrentEDD Series card u-Ring West edge status
1.3.6.1.4.1.4756.20.440.20.1.115ColumnedduRingInst2WeststsLocalread-onlycurrentEDD Series card u-Ring West status
1.3.6.1.4.1.4756.20.440.20.1.116ColumnedduRingInst2WestEdgestsLocalread-onlycurrentEDD Series card u-Ring West status
1.3.6.1.4.1.4756.20.440.20.1.117ColumnedduRingInst2healthystsLocalread-onlycurrentEDD Series card u-Ring healthy status None Fine Fault
1.3.6.1.4.1.4756.20.440.20.1.118ColumneddDeviceActiveLocalread-writecurrentEDD Series card u-Ring device active 0: Disable 1: Enable
1.3.6.1.4.1.4756.20.440.20.1.119ColumneddFx1DDLocalread-onlycurrentEDD Series card fiber port Digital Diagnostic function: 0:No 1:Yes
1.3.6.1.4.1.4756.20.440.20.1.120ColumneddFx1DDVendorLocalread-onlycurrentEDD Series card fiber port D/D information: Vendor name
1.3.6.1.4.1.4756.20.440.20.1.121ColumneddFx1DDPartNoLocalread-onlycurrentEDD Series card fiber port D/D information: Vendor part number
1.3.6.1.4.1.4756.20.440.20.1.122ColumneddFx1DDFiberTypeLocalread-onlycurrentEDD Series card fiber port D/D information: Fiber Type
1.3.6.1.4.1.4756.20.440.20.1.123ColumneddFx1DDWaveLenLocalread-onlycurrentEDD Series card fiber port D/D information: Wave length
1.3.6.1.4.1.4756.20.440.20.1.124ColumneddFx1DDWaveLen2Localread-onlycurrentEDD Series card fiber port D/D information: Wave length 2
1.3.6.1.4.1.4756.20.440.20.1.125ColumneddFx1DDLinkLenLocalread-onlycurrentEDD Series card fiber port D/D information: Link length
1.3.6.1.4.1.4756.20.440.20.1.126ColumneddFx1DDLenUnitLocalread-onlycurrentEDD Series card fiber port D/D information: Length Unit
1.3.6.1.4.1.4756.20.440.20.1.127ColumneddFx1DDStatusLocalread-onlycurrentEDD Series card fiber port D/D information: Status Support
1.3.6.1.4.1.4756.20.440.20.1.128ColumneddFx1DDRxSensLocalread-onlycurrentEDD Series card fiber port D/D information: Rx Sensitivity
1.3.6.1.4.1.4756.20.440.20.1.129ColumneddFx1DDTxPWRLocalread-onlycurrentEDD Series card fiber port D/D information: Tx power
1.3.6.1.4.1.4756.20.440.20.1.130ColumneddFx1DDRxPWRLocalread-onlycurrentEDD Series card fiber port D/D information: Rx power
1.3.6.1.4.1.4756.20.440.20.1.131ColumneddFx1DDTempLocalread-onlycurrentEDD Series card fiber port D/D information: Temperature in degree C
1.3.6.1.4.1.4756.20.440.20.1.132ColumneddFx1DDPWRMarginLocalread-onlycurrentEDD Series card fiber port D/D information: Power margin
1.3.6.1.4.1.4756.20.440.20.1.133ColumneddFx1DDPWRLossLocalread-onlycurrentEDD Series card fiber port D/D information: Power loss
1.3.6.1.4.1.4756.20.440.20.1.134ColumneddFx2DDLocalread-onlycurrentEDD Series card fiber2 Digital Diagnostic function: 0:NO 1:Yes
1.3.6.1.4.1.4756.20.440.20.1.135ColumneddFx2DDVendorLocalread-onlycurrentEDD Series card fiber2 D/D information: Vendor name
1.3.6.1.4.1.4756.20.440.20.1.136ColumneddFx2DDPartNoLocalread-onlycurrentEDD Series card fiber2 D/D information: Vendor part number
1.3.6.1.4.1.4756.20.440.20.1.137ColumneddFx2DDFiberTypeLocalread-onlycurrentEDD Series card fiber2 D/D information: Fiber Type
1.3.6.1.4.1.4756.20.440.20.1.138ColumneddFx2DDWaveLenLocalread-onlycurrentEDD Series card fiber2 D/D information: Wave length 1
1.3.6.1.4.1.4756.20.440.20.1.139ColumneddFx2DDWaveLen2Localread-onlycurrentEDD Series card fiber2 D/D information: Wave length 2
1.3.6.1.4.1.4756.20.440.20.1.140ColumneddFx2DDLinkLenLocalread-onlycurrentEDD Series card fiber2 D/D information: Link length
1.3.6.1.4.1.4756.20.440.20.1.141ColumneddFx2DDLenUnitLocalread-onlycurrentEDD Series card fiber2 D/D information: Length Unit
1.3.6.1.4.1.4756.20.440.20.1.142ColumneddFx2DDStatusLocalread-onlycurrentEDD Series card fiber2 D/D information: Status Support
1.3.6.1.4.1.4756.20.440.20.1.143ColumneddFx2DDRxSensLocalread-onlycurrentEDD Series card fiber2 D/D information: Rx Sensitivity
1.3.6.1.4.1.4756.20.440.20.1.144ColumneddFx2DDTxPWRLocalread-onlycurrentEDD Series card fiber2 D/D information: Tx power
1.3.6.1.4.1.4756.20.440.20.1.145ColumneddFx2DDRxPWRLocalread-onlycurrentEDD Series card fiber2 D/D information: Rx power
1.3.6.1.4.1.4756.20.440.20.1.146ColumneddFx2DDTempLocalread-onlycurrentEDD Series card fiber2 D/D information: Temperature in degree C
1.3.6.1.4.1.4756.20.440.20.1.147ColumneddFx2DDPWRMarginLocalread-onlycurrentEDD Series card fiber2 D/D information: Power margin
1.3.6.1.4.1.4756.20.440.20.1.148ColumneddFx2DDPWRLossLocalread-onlycurrentEDD Series card fiber2 D/D information: Power loss
1.3.6.1.4.1.4756.20.440.20.1.149ColumneddFx3DDLocalread-onlycurrentEDD Series card fiber3 Digital Diagnostic function: 0:NO 1:Yes
1.3.6.1.4.1.4756.20.440.20.1.150ColumneddFx3DDVendorLocalread-onlycurrentEDD Series card fiber3 D/D information: Vendor name
1.3.6.1.4.1.4756.20.440.20.1.151ColumneddFx3DDPartNoLocalread-onlycurrentEDD Series card fiber32 D/D information: Vendor part number
1.3.6.1.4.1.4756.20.440.20.1.152ColumneddFx3DDFiberTypeLocalread-onlycurrentEDD Series card fiber3 D/D information: Fiber Type
1.3.6.1.4.1.4756.20.440.20.1.153ColumneddFx3DDWaveLenLocalread-onlycurrentEDD Series card fiber3 D/D information: Wave length 1
1.3.6.1.4.1.4756.20.440.20.1.154ColumneddFx3DDWaveLen2Localread-onlycurrentEDD Series card fiber3 D/D information: Wave length 2
1.3.6.1.4.1.4756.20.440.20.1.155ColumneddFx3DDLinkLenLocalread-onlycurrentEDD Series card fiber3 D/D information: Link length
1.3.6.1.4.1.4756.20.440.20.1.156ColumneddFx3DDLenUnitLocalread-onlycurrentEDD Series card fiber3 D/D information: Length Unit
1.3.6.1.4.1.4756.20.440.20.1.157ColumneddFx3DDStatusLocalread-onlycurrentEDD Series card fiber3 D/D information: Status Support
1.3.6.1.4.1.4756.20.440.20.1.158ColumneddFx3DDRxSensLocalread-onlycurrentEDD Series card fiber3 D/D information: Rx Sensitivity
1.3.6.1.4.1.4756.20.440.20.1.159ColumneddFx3DDTxPWRLocalread-onlycurrentEDD Series card fiber3 D/D information: Tx power
1.3.6.1.4.1.4756.20.440.20.1.160ColumneddFx3DDRxPWRLocalread-onlycurrentEDD Series card fiber3 D/D information: Rx power
1.3.6.1.4.1.4756.20.440.20.1.161ColumneddFx3DDTempLocalread-onlycurrentEDD Series card fiber3 D/D information: Temperature in degree C
1.3.6.1.4.1.4756.20.440.20.1.162ColumneddFx3DDPWRMarginLocalread-onlycurrentEDD Series card fiber3 D/D information: Power margin
1.3.6.1.4.1.4756.20.440.20.1.163ColumneddFx3DDPWRLossLocalread-onlycurrentEDD Series card fiber3 D/D information: Power loss
1.3.6.1.4.1.4756.20.440.20.1.164ColumneddTestLocalread-onlycurrentEDD Series card test led sts: 0: Off 1: On
1.3.6.1.4.1.4756.20.440.20.1.165ColumneddClearPortCounterLocalread-writecurrentEDD Series card clear port counter: 0: Off 1: Action
1.3.6.1.4.1.4756.20.440.20.1.166ColumneddAggrSourceMACAddrLocalread-writecurrentEDD Series card Aggregation Mode Configuration: Source MAC Address 0: No 1: Yes
1.3.6.1.4.1.4756.20.440.20.1.167ColumneddAggrDestinationMACAddrLocalread-writecurrentEDD Series card Aggregation Mode Configuration: Destination MAC Address 0: No 1: Yes
1.3.6.1.4.1.4756.20.440.20.1.168ColumneddAggrIPAddrLocalread-writecurrentEDD Series card Aggregation Mode Configuration: IP Address 0: No 1: Yes
1.3.6.1.4.1.4756.20.440.20.1.169ColumneddAggrTCPUDPPortNumLocalread-writecurrentEDD Series card Aggregation Mode Configuration: TCP/UDP Port Number 0: No 1: Yes
1.3.6.1.4.1.4756.20.440.20.1.170ColumneddAggrGroupPort1ConfLocalread-writecurrentEDD Series card Aggregation Group Port1 Configuration: 0: Normal 1: ID1 2: ID2
1.3.6.1.4.1.4756.20.440.20.1.171ColumneddAggrGroupPort2ConfLocalread-writecurrentEDD Series card Aggregation Group Port2 Configuration: 0: Normal 1: ID1 2: ID2
1.3.6.1.4.1.4756.20.440.20.1.172ColumneddAggrGroupPort3ConfLocalread-writecurrentEDD Series card Aggregation Group Port3 Configuration: 0: Normal 1: ID1 2: ID2
1.3.6.1.4.1.4756.20.440.20.1.173ColumneddAggrGroupPort4ConfLocalread-writecurrentEDD Series card Aggregation Group Port4 Configuration: 0: Normal 1: ID1 2: ID2
1.3.6.1.4.1.4756.20.440.20.1.174ColumneddPort1LACPEnabledLocalread-writecurrentEDD Series card Port1 LACP Enabled: 0: No 1: Yes
1.3.6.1.4.1.4756.20.440.20.1.175ColumneddPort1LACPKEYLocalread-writecurrentEDD Series card Port1 LACP Key value: The Key value incurred by the port, range 0-65535.The value of 0 means auto.
1.3.6.1.4.1.4756.20.440.20.1.176ColumneddPort1LACPRoleLocalread-writecurrentEDD Series card Port1 LACP Role: 0: Passive 1: Active
1.3.6.1.4.1.4756.20.440.20.1.177ColumneddPort1LACPTimeOutLocalread-writecurrentEDD Series card Port1 LACP Time out: 0: Slow 1: Fast
1.3.6.1.4.1.4756.20.440.20.1.178ColumneddPort1LACPPrioLocalread-writecurrentEDD Series card Port1 LACP priority: The Key value incurred by the port, range 1-65535.
1.3.6.1.4.1.4756.20.440.20.1.179ColumneddPort2LACPEnabledLocalread-writecurrentEDD Series card Port2 LACP Enabled: 0: No 1: Yes
1.3.6.1.4.1.4756.20.440.20.1.180ColumneddPort2LACPKEYLocalread-writecurrentEDD Series card Port2 LACP Key value: The Key value incurred by the port, range 0-65535.The value of 0 means auto.
1.3.6.1.4.1.4756.20.440.20.1.181ColumneddPort2LACPRoleLocalread-writecurrentEDD Series card Port2 LACP Role: 0: Passive 1: Active
1.3.6.1.4.1.4756.20.440.20.1.182ColumneddPort2LACPTimeOutLocalread-writecurrentEDD Series card Port2 LACP Time out: 0: Slow 1: Fast
1.3.6.1.4.1.4756.20.440.20.1.183ColumneddPort2LACPPrioLocalread-writecurrentEDD Series card Port2 LACP priority: The Key value incurred by the port, range 1-65535.
1.3.6.1.4.1.4756.20.440.20.1.184ColumneddPort3LACPEnabledLocalread-writecurrentEDD Series card Port3 LACP Enabled: 0: No 1: Yes
1.3.6.1.4.1.4756.20.440.20.1.185ColumneddPort3LACPKEYLocalread-writecurrentEDD Series card Port3 LACP Key value: The Key value incurred by the port, range 0-65535.The value of 0 means auto.
1.3.6.1.4.1.4756.20.440.20.1.186ColumneddPort3LACPRoleLocalread-writecurrentEDD Series card Port3 LACP Role: 0: Passive 1: Active
1.3.6.1.4.1.4756.20.440.20.1.187ColumneddPort3LACPTimeOutLocalread-writecurrentEDD Series card Port3 LACP Time out: 0: Slow 1: Fast
1.3.6.1.4.1.4756.20.440.20.1.188ColumneddPort3LACPPrioLocalread-writecurrentEDD Series card Port3 LACP priority: The Key value incurred by the port, range 1-65535.
1.3.6.1.4.1.4756.20.440.20.1.189ColumneddPort4LACPEnabledLocalread-writecurrentEDD Series card Port4 LACP Enabled: 0: No 1: Yes
1.3.6.1.4.1.4756.20.440.20.1.190ColumneddPort4LACPKEYLocalread-writecurrentEDD Series card Port4 LACP Key value: The Key value incurred by the port, range 0-65535.The value of 0 means auto.
1.3.6.1.4.1.4756.20.440.20.1.191ColumneddPort4LACPRoleLocalread-writecurrentEDD Series card Port4 LACP Role: 0: Passive 1: Active
1.3.6.1.4.1.4756.20.440.20.1.192ColumneddPort4LACPTimeOutLocalread-writecurrentEDD Series card Port4 LACP Time out: 0: Slow 1: Fast
1.3.6.1.4.1.4756.20.440.20.1.193ColumneddPort4LACPPrioLocalread-writecurrentEDD Series card Port4 LACP priority: The Key value incurred by the port, range 1-65535.
1.3.6.1.4.1.4756.20.440.20.1.194ColumneddPort1LACPstsLocalread-onlycurrentEDD Series card Port1 LACP status: 0: No 1: Yes 2: Standby
1.3.6.1.4.1.4756.20.440.20.1.195ColumneddPort1LACPKEYstsLocalread-onlycurrentEDD Series card Port1 LACP status: Key
1.3.6.1.4.1.4756.20.440.20.1.196ColumneddPort1LACPAggrIDstsLocalread-onlycurrentEDD Series card Port1 LACP status: Aggr ID
1.3.6.1.4.1.4756.20.440.20.1.197ColumneddPort1LACPParnterSysIDstsLocalread-onlycurrentEDD Series card Port1 LACP status: Parnter System ID
1.3.6.1.4.1.4756.20.440.20.1.198ColumneddPort1LACPParnterPortstsLocalread-onlycurrentEDD Series card Port1 LACP status: Parnter Port Status
1.3.6.1.4.1.4756.20.440.20.1.199ColumneddPort1LACPParnterProistsLocalread-onlycurrentEDD Series card Port1 LACP status: Parnter Priority
1.3.6.1.4.1.4756.20.440.20.1.200ColumneddPort2LACPstsLocalread-onlycurrentEDD Series card Port2 LACP status: 0: No 1: Yes 2: Standby
1.3.6.1.4.1.4756.20.440.20.1.201ColumneddPort2LACPKEYstsLocalread-onlycurrentEDD Series card Port2 LACP status: Key
1.3.6.1.4.1.4756.20.440.20.1.202ColumneddPort2LACPAggrIDstsLocalread-onlycurrentEDD Series card Port2 LACP status: Aggr ID
1.3.6.1.4.1.4756.20.440.20.1.203ColumneddPort2LACPParnterSysIDstsLocalread-onlycurrentEDD Series card Port2 LACP status: Parnter System ID
1.3.6.1.4.1.4756.20.440.20.1.204ColumneddPort2LACPParnterPortstsLocalread-onlycurrentEDD Series card Port2 LACP status: Parnter Port Status
1.3.6.1.4.1.4756.20.440.20.1.205ColumneddPort2LACPParnterProistsLocalread-onlycurrentEDD Series card Port2 LACP status: Parnter Priority
1.3.6.1.4.1.4756.20.440.20.1.206ColumneddPort3LACPstsLocalread-onlycurrentEDD Series card Port3 LACP status: 0: No 1: Yes 2: Standby
1.3.6.1.4.1.4756.20.440.20.1.207ColumneddPort3LACPKEYstsLocalread-onlycurrentEDD Series card Port3 LACP status: Key
1.3.6.1.4.1.4756.20.440.20.1.208ColumneddPort3LACPAggrIDstsLocalread-onlycurrentEDD Series card Port3 LACP status: Aggr ID
1.3.6.1.4.1.4756.20.440.20.1.209ColumneddPort3LACPParnterSysIDstsLocalread-onlycurrentEDD Series card Port3 LACP status: Parnter System ID
1.3.6.1.4.1.4756.20.440.20.1.210ColumneddPort3LACPParnterPortstsLocalread-onlycurrentEDD Series card Port3 LACP status: Parnter Port Status
1.3.6.1.4.1.4756.20.440.20.1.211ColumneddPort3LACPParnterProistsLocalread-onlycurrentEDD Series card Port3 LACP status: Parnter Priority
1.3.6.1.4.1.4756.20.440.20.1.212ColumneddPort4LACPstsLocalread-onlycurrentEDD Series card Port4 LACP status: 0: No 1: Yes 2: Standby
1.3.6.1.4.1.4756.20.440.20.1.213ColumneddPort4LACPKEYstsLocalread-onlycurrentEDD Series card Port4 LACP status: Key
1.3.6.1.4.1.4756.20.440.20.1.214ColumneddPort4LACPAggrIDstsLocalread-onlycurrentEDD Series card Port4 LACP status: Aggr ID
1.3.6.1.4.1.4756.20.440.20.1.215ColumneddPort4LACPParnterSysIDstsLocalread-onlycurrentEDD Series card Port4 LACP status: Parnter System ID
1.3.6.1.4.1.4756.20.440.20.1.216ColumneddPort4LACPParnterPortstsLocalread-onlycurrentEDD Series card Port4 LACP status: Parnter Port Status
1.3.6.1.4.1.4756.20.440.20.1.217ColumneddPort4LACPParnterProistsLocalread-onlycurrentEDD Series card Port4 LACP status: Parnter Priority
1.3.6.1.4.1.4756.20.440.20.1.218ColumneddOAMPort1EnableLocalread-writecurrentEDD Series card Port1 OAM: 0: Off 1: On
1.3.6.1.4.1.4756.20.440.20.1.219ColumneddOAMPort1ModeLocalread-writecurrentEDD Series card Port1 OAM: 0: Passive 1: Active
1.3.6.1.4.1.4756.20.440.20.1.220ColumneddOAMPort1LoopBackLocalread-writecurrentEDD Series card Port1 OAM LoopBack: 0: Off 1: On
1.3.6.1.4.1.4756.20.440.20.1.221ColumneddOAMPort1LinkMonitorLocalread-writecurrentEDD Series card Port1 OAM Link Monitor: 0: Off 1: On
1.3.6.1.4.1.4756.20.440.20.1.222ColumneddOAMPort1MIBRetrievalLocalread-writecurrentEDD Series card Port1 OAM MIB Retrieval: 0: Off 1: On
1.3.6.1.4.1.4756.20.440.20.1.223ColumneddOAMPort1LoopBackOPLocalread-writecurrentEDD Series card Port1 OAM LoopBack operation: 0: Off 1: On
1.3.6.1.4.1.4756.20.440.20.1.224ColumneddOAMPort2EnableLocalread-writecurrentEDD Series card Port2 OAM: 0: Off 1: On
1.3.6.1.4.1.4756.20.440.20.1.225ColumneddOAMPort2ModeLocalread-writecurrentEDD Series card Port2 OAM: 0: Passive 1: Active
1.3.6.1.4.1.4756.20.440.20.1.226ColumneddOAMPort2LoopBackLocalread-writecurrentEDD Series card Port2 OAM LoopBack: 0: Off 1: On
1.3.6.1.4.1.4756.20.440.20.1.227ColumneddOAMPort2LinkMonitorLocalread-writecurrentEDD Series card Port2 OAM Link Monitor: 0: Off 1: On
1.3.6.1.4.1.4756.20.440.20.1.228ColumneddOAMPort2MIBRetrievalLocalread-writecurrentEDD Series card Port2 OAM MIB Retrieval: 0: Off 1: On
1.3.6.1.4.1.4756.20.440.20.1.229ColumneddOAMPort2LoopBackOPLocalread-writecurrentEDD Series card Port2 OAM LoopBack operation: 0: Off 1: On
1.3.6.1.4.1.4756.20.440.20.1.230ColumneddOAMPort3EnableLocalread-writecurrentEDD Series card Port3 OAM: 0: Off 1: On
1.3.6.1.4.1.4756.20.440.20.1.231ColumneddOAMPort3ModeLocalread-writecurrentEDD Series card Port3 OAM: 0: Passive 1: Active
1.3.6.1.4.1.4756.20.440.20.1.232ColumneddOAMPort3LoopBackLocalread-writecurrentEDD Series card Port3 OAM: 0: Off 1: On
1.3.6.1.4.1.4756.20.440.20.1.233ColumneddOAMPort3LinkMonitorLocalread-writecurrentEDD Series card Port3 OAM Link Monitor: 0: Off 1: On
1.3.6.1.4.1.4756.20.440.20.1.234ColumneddOAMPort3MIBRetrievalLocalread-writecurrentEDD Series card Port3 OAM MIB Retrieval: 0: Off 1: On
1.3.6.1.4.1.4756.20.440.20.1.235ColumneddOAMPort3LoopBackOPLocalread-writecurrentEDD Series card Port3 OAM LoopBack operation: 0: Disable 1: Enable
1.3.6.1.4.1.4756.20.440.20.1.236ColumneddOAMPort4EnableLocalread-writecurrentEDD Series card Port4 OAM: 0: Off 1: On
1.3.6.1.4.1.4756.20.440.20.1.237ColumneddOAMPort4ModeLocalread-writecurrentEDD Series card Port4 OAM: 0: Passive 1: Active
1.3.6.1.4.1.4756.20.440.20.1.238ColumneddOAMPort4LoopBackLocalread-writecurrentEDD Series card Port4 OAM: 0: Off 1: On
1.3.6.1.4.1.4756.20.440.20.1.239ColumneddOAMPort4LinkMonitorLocalread-writecurrentEDD Series card Port4 OAM Link Monitor: 0: Off 1: On
1.3.6.1.4.1.4756.20.440.20.1.240ColumneddOAMPort4MIBRetrievalLocalread-writecurrentEDD Series card Port4 OAM MIB Retrieval: 0: Off 1: On
1.3.6.1.4.1.4756.20.440.20.1.241ColumneddOAMPort4LoopBackOPLocalread-writecurrentEDD Series card Port4 OAM LoopBack operation: 0: On 1: Off
1.3.6.1.4.1.4756.20.440.20.1.242ColumneddPort1EFEErrorWindowLocalread-writecurrentEDD Series card Port1 Link Event Configuration: Error Frame Event - Error Window
1.3.6.1.4.1.4756.20.440.20.1.243ColumneddPort1EFEErrorThresholdLocalread-writecurrentEDD Series card Port1 Link Event Configuration: Error Frame Event - Error Threshold
1.3.6.1.4.1.4756.20.440.20.1.244ColumneddPort1SPEEErrorWindowLocalread-writecurrentEDD Series card Port1 Link Event Configuration: Symbol Period Error Event - Error Window
1.3.6.1.4.1.4756.20.440.20.1.245ColumneddPort1SPEEErrorThresholdLocalread-writecurrentEDD Series card Port1 Link Event Configuration: Symbol Period Error Event - Error Threshold
1.3.6.1.4.1.4756.20.440.20.1.246ColumneddPort1SSEErrorWindowLocalread-writecurrentEDD Series card Port1 Link Event Configuration: Seconds Summary Event - Error Window
1.3.6.1.4.1.4756.20.440.20.1.247ColumneddPort1SSEErrorThresholdLocalread-writecurrentEDD Series card Port1 Link Event Configuration: Seconds Summary Event - Error Threshold
1.3.6.1.4.1.4756.20.440.20.1.248ColumneddPort2EFEErrorWindowLocalread-writecurrentEDD Series card Port2 Link Event Configuration: Error Frame Event - Error Window
1.3.6.1.4.1.4756.20.440.20.1.249ColumneddPort2EFEErrorThresholdLocalread-writecurrentEDD Series card Port2 Link Event Configuration: Error Frame Event - Error Threshold
1.3.6.1.4.1.4756.20.440.20.1.250ColumneddPort2SPEEErrorWindowLocalread-writecurrentEDD Series card Port2 Link Event Configuration: Symbol Period Error Event - Error Window
1.3.6.1.4.1.4756.20.440.20.1.251ColumneddPort2SPEEErrorThresholdLocalread-writecurrentEDD Series card Port2 Link Event Configuration: Symbol Period Error Event - Error Threshold
1.3.6.1.4.1.4756.20.440.20.1.252ColumneddPort2SSEErrorWindowLocalread-writecurrentEDD Series card Port2 Link Event Configuration: Seconds Summary Event - Error Window
1.3.6.1.4.1.4756.20.440.20.1.253ColumneddPort2SSEErrorThresholdLocalread-writecurrentEDD Series card Port2 Link Event Configuration: Seconds Summary Event - Error Threshold
1.3.6.1.4.1.4756.20.440.20.1.254ColumneddPort3EFEErrorWindowLocalread-writecurrentEDD Series card Port3 Link Event Configuration: Error Frame Event - Error Window
1.3.6.1.4.1.4756.20.440.20.1.255ColumneddPort3EFEErrorThresholdLocalread-writecurrentEDD Series card Port3 Link Event Configuration: Error Frame Event - Error Threshold
1.3.6.1.4.1.4756.20.440.20.1.256ColumneddPort3SPEEErrorWindowLocalread-writecurrentEDD Series card Port3 Link Event Configuration: Symbol Period Error Event - Error Window
1.3.6.1.4.1.4756.20.440.20.1.257ColumneddPort3SPEEErrorThresholdLocalread-writecurrentEDD Series card Port3 Link Event Configuration: Symbol Period Error Event - Error Threshold
1.3.6.1.4.1.4756.20.440.20.1.258ColumneddPort3SSEErrorWindowLocalread-writecurrentEDD Series card Port3 Link Event Configuration: Seconds Summary Event - Error Window
1.3.6.1.4.1.4756.20.440.20.1.259ColumneddPort3SSEErrorThresholdLocalread-writecurrentEDD Series card Port3 Link Event Configuration: Seconds Summary Event - Error Threshold
1.3.6.1.4.1.4756.20.440.20.1.260ColumneddPort4EFEErrorWindowLocalread-writecurrentEDD Series card Port4 Link Event Configuration: Error Frame Event - Error Window
1.3.6.1.4.1.4756.20.440.20.1.261ColumneddPort4EFEErrorThresholdLocalread-writecurrentEDD Series card Port4 Link Event Configuration: Error Frame Event - Error Threshold
1.3.6.1.4.1.4756.20.440.20.1.262ColumneddPort4SPEEErrorWindowLocalread-writecurrentEDD Series card Port4 Link Event Configuration: Symbol Period Error Event - Error Window
1.3.6.1.4.1.4756.20.440.20.1.263ColumneddPort4SPEEErrorThresholdLocalread-writecurrentEDD Series card Port4 Link Event Configuration: Symbol Period Error Event - Error Threshold
1.3.6.1.4.1.4756.20.440.20.1.264ColumneddPort4SSEErrorWindowLocalread-writecurrentEDD Series card Port4 Link Event Configuration: Seconds Summary Event - Error Window
1.3.6.1.4.1.4756.20.440.20.1.265ColumneddPort4SSEErrorThresholdLocalread-writecurrentEDD Series card Port4 Link Event Configuration: Seconds Summary Event - Error Threshold
1.3.6.1.4.1.4756.20.440.20.1.266ColumneddPort1RxOAMInfoPDULocalread-onlycurrentEDD Series card Port1 Detailed Link OAM Statistics: Rx OAM Information PDU's
1.3.6.1.4.1.4756.20.440.20.1.267ColumneddPort1RxUniqueErrorEventLocalread-onlycurrentEDD Series card Port1 Detailed Link OAM Statistics: Rx Unique Error Event Notificatio
1.3.6.1.4.1.4756.20.440.20.1.268ColumneddPort1RxDuplicateErrorEventLocalread-onlycurrentEDD Series card Port1 Detailed Link OAM Statistics: Rx Duplicate Error Event Notification
1.3.6.1.4.1.4756.20.440.20.1.269ColumneddPort1RxLoopBackControlLocalread-onlycurrentEDD Series card Port1 Detailed Link OAM Statistics: Rx Loopback Control
1.3.6.1.4.1.4756.20.440.20.1.270ColumneddPort1RxVariableRequestLocalread-onlycurrentEDD Series card Port1 Detailed Link OAM Statistics: Rx Variable Request
1.3.6.1.4.1.4756.20.440.20.1.271ColumneddPort1RxVariableResponseLocalread-onlycurrentEDD Series card Port1 Detailed Link OAM Statistics: Rx Variable Response
1.3.6.1.4.1.4756.20.440.20.1.272ColumneddPort1RxOrgSpecificPDULocalread-onlycurrentEDD Series card Port1 Detailed Link OAM Statistics: Rx Org Specific PDU's
1.3.6.1.4.1.4756.20.440.20.1.273ColumneddPort1RxUnsupportedCodesLocalread-onlycurrentEDD Series card Port1 Detailed Link OAM Statistics: Rx Unsupported Codes
1.3.6.1.4.1.4756.20.440.20.1.274ColumneddPort1RxLinkFaultPDULocalread-onlycurrentEDD Series card Port1 Detailed Link OAM Statistics: Rx Link Fault PDU's
1.3.6.1.4.1.4756.20.440.20.1.275ColumneddPort1RxDyingGaspLocalread-onlycurrentEDD Series card Port1 Detailed Link OAM Statistics: Rx Dying Gasp
1.3.6.1.4.1.4756.20.440.20.1.276ColumneddPort1RxCriticalEventPDULocalread-onlycurrentEDD Series card Port1 Detailed Link OAM Statistics: Rx Dying Gasp
1.3.6.1.4.1.4756.20.440.20.1.277ColumneddPort1TxOAMInfoPDULocalread-onlycurrentEDD Series card Port1 Detailed Link OAM Statistics: Tx OAM Information PDU's
1.3.6.1.4.1.4756.20.440.20.1.278ColumneddPort1TxUniqueErrorEventLocalread-onlycurrentEDD Series card Port1 Detailed Link OAM Statistics: Tx Unique Error Event Notificatio
1.3.6.1.4.1.4756.20.440.20.1.279ColumneddPort1TxDuplicateErrorEventLocalread-onlycurrentEDD Series card Port1 Detailed Link OAM Statistics: Tx Duplicate Error Event Notification
1.3.6.1.4.1.4756.20.440.20.1.280ColumneddPort1TxLoopBackControlLocalread-onlycurrentEDD Series card Port1 Detailed Link OAM Statistics: Tx Loopback Control
1.3.6.1.4.1.4756.20.440.20.1.281ColumneddPort1TxVariableRequestLocalread-onlycurrentEDD Series card Port1 Detailed Link OAM Statistics: Tx Variable Request
1.3.6.1.4.1.4756.20.440.20.1.282ColumneddPort1TxVariableResponseLocalread-onlycurrentEDD Series card Port1 Detailed Link OAM Statistics: Tx Variable Response
1.3.6.1.4.1.4756.20.440.20.1.283ColumneddPort1TxOrgSpecificPDULocalread-onlycurrentEDD Series card Port1 Detailed Link OAM Statistics: Tx Org Specific PDU's
1.3.6.1.4.1.4756.20.440.20.1.284ColumneddPort1TxUnsupportedCodesLocalread-onlycurrentEDD Series card Port1 Detailed Link OAM Statistics: Tx Unsupported Codes
1.3.6.1.4.1.4756.20.440.20.1.285ColumneddPort1TxLinkFaultPDULocalread-onlycurrentEDD Series card Port1 Detailed Link OAM Statistics: Tx Link Fault PDU's
1.3.6.1.4.1.4756.20.440.20.1.286ColumneddPort1TxDyingGaspLocalread-onlycurrentEDD Series card Port1 Detailed Link OAM Statistics: Tx Dying Gasp
1.3.6.1.4.1.4756.20.440.20.1.287ColumneddPort1TxCriticalEventPDULocalread-onlycurrentEDD Series card Port1 Detailed Link OAM Statistics: Tx Dying Gasp
1.3.6.1.4.1.4756.20.440.20.1.288ColumneddPort2RxOAMInfoPDULocalread-onlycurrentEDD Series card Port2 Detailed Link OAM Statistics: Rx OAM Information PDU's
1.3.6.1.4.1.4756.20.440.20.1.289ColumneddPort2RxUniqueErrorEventLocalread-onlycurrentEDD Series card Port2 Detailed Link OAM Statistics: Rx Unique Error Event Notificatio
1.3.6.1.4.1.4756.20.440.20.1.290ColumneddPort2RxDuplicateErrorEventLocalread-onlycurrentEDD Series card Port2 Detailed Link OAM Statistics: Rx Duplicate Error Event Notification
1.3.6.1.4.1.4756.20.440.20.1.291ColumneddPort2RxLoopBackControlLocalread-onlycurrentEDD Series card Port2 Detailed Link OAM Statistics: Rx Loopback Control
1.3.6.1.4.1.4756.20.440.20.1.292ColumneddPort2RxVariableRequestLocalread-onlycurrentEDD Series card Port2 Detailed Link OAM Statistics: Rx Variable Request
1.3.6.1.4.1.4756.20.440.20.1.293ColumneddPort2RxVariableResponseLocalread-onlycurrentEDD Series card Port2 Detailed Link OAM Statistics: Rx Variable Response
1.3.6.1.4.1.4756.20.440.20.1.294ColumneddPort2RxOrgSpecificPDULocalread-onlycurrentEDD Series card Port2 Detailed Link OAM Statistics: Rx Org Specific PDU's
1.3.6.1.4.1.4756.20.440.20.1.295ColumneddPort2RxUnsupportedCodesLocalread-onlycurrentEDD Series card Port2 Detailed Link OAM Statistics: Rx Unsupported Codes
1.3.6.1.4.1.4756.20.440.20.1.296ColumneddPort2RxLinkFaultPDULocalread-onlycurrentEDD Series card Port2 Detailed Link OAM Statistics: Rx Link Fault PDU's
1.3.6.1.4.1.4756.20.440.20.1.297ColumneddPort2RxDyingGaspLocalread-onlycurrentEDD Series card Port2 Detailed Link OAM Statistics: Rx Dying Gasp
1.3.6.1.4.1.4756.20.440.20.1.298ColumneddPort2RxCriticalEventPDULocalread-onlycurrentEDD Series card Port2 Detailed Link OAM Statistics: Rx Dying Gasp
1.3.6.1.4.1.4756.20.440.20.1.299ColumneddPort2TxOAMInfoPDULocalread-onlycurrentEDD Series card Port2 Detailed Link OAM Statistics: Tx OAM Information PDU's
1.3.6.1.4.1.4756.20.440.20.1.300ColumneddPort2TxUniqueErrorEventLocalread-onlycurrentEDD Series card Port2 Detailed Link OAM Statistics: Tx Unique Error Event Notificatio
1.3.6.1.4.1.4756.20.440.20.1.301ColumneddPort2TxDuplicateErrorEventLocalread-onlycurrentEDD Series card Port2 Detailed Link OAM Statistics: Tx Duplicate Error Event Notification
1.3.6.1.4.1.4756.20.440.20.1.302ColumneddPort2TxLoopBackControlLocalread-onlycurrentEDD Series card Port2 Detailed Link OAM Statistics: Tx Loopback Control
1.3.6.1.4.1.4756.20.440.20.1.303ColumneddPort2TxVariableRequestLocalread-onlycurrentEDD Series card Port2 Detailed Link OAM Statistics: Tx Variable Request
1.3.6.1.4.1.4756.20.440.20.1.304ColumneddPort2TxVariableResponseLocalread-onlycurrentEDD Series card Port2 Detailed Link OAM Statistics: Tx Variable Response
1.3.6.1.4.1.4756.20.440.20.1.305ColumneddPort2TxOrgSpecificPDULocalread-onlycurrentEDD Series card Port2 Detailed Link OAM Statistics: Tx Org Specific PDU's
1.3.6.1.4.1.4756.20.440.20.1.306ColumneddPort2TxUnsupportedCodesLocalread-onlycurrentEDD Series card Port2 Detailed Link OAM Statistics: Tx Unsupported Codes
1.3.6.1.4.1.4756.20.440.20.1.307ColumneddPort2TxLinkFaultPDULocalread-onlycurrentEDD Series card Port2 Detailed Link OAM Statistics: Tx Link Fault PDU's
1.3.6.1.4.1.4756.20.440.20.1.308ColumneddPort2TxDyingGaspLocalread-onlycurrentEDD Series card Port2 Detailed Link OAM Statistics: Tx Dying Gasp
1.3.6.1.4.1.4756.20.440.20.1.309ColumneddPort2TxCriticalEventPDULocalread-onlycurrentEDD Series card Port2 Detailed Link OAM Statistics: Tx Dying Gasp
1.3.6.1.4.1.4756.20.440.20.1.310ColumneddPort3RxOAMInfoPDULocalread-onlycurrentEDD Series card Port3 Detailed Link OAM Statistics: Rx OAM Information PDU's
1.3.6.1.4.1.4756.20.440.20.1.311ColumneddPort3RxUniqueErrorEventLocalread-onlycurrentEDD Series card Port3 Detailed Link OAM Statistics: Rx Unique Error Event Notificatio
1.3.6.1.4.1.4756.20.440.20.1.312ColumneddPort3RxDuplicateErrorEventLocalread-onlycurrentEDD Series card Port3 Detailed Link OAM Statistics: Rx Duplicate Error Event Notification
1.3.6.1.4.1.4756.20.440.20.1.313ColumneddPort3RxLoopBackControlLocalread-onlycurrentEDD Series card Port3 Detailed Link OAM Statistics: Rx Loopback Control
1.3.6.1.4.1.4756.20.440.20.1.314ColumneddPort3RxVariableRequestLocalread-onlycurrentEDD Series card Port3 Detailed Link OAM Statistics: Rx Variable Request
1.3.6.1.4.1.4756.20.440.20.1.315ColumneddPort3RxVariableResponseLocalread-onlycurrentEDD Series card Port3 Detailed Link OAM Statistics: Rx Variable Response
1.3.6.1.4.1.4756.20.440.20.1.316ColumneddPort3RxOrgSpecificPDULocalread-onlycurrentEDD Series card Port3 Detailed Link OAM Statistics: Rx Org Specific PDU's
1.3.6.1.4.1.4756.20.440.20.1.317ColumneddPort3RxUnsupportedCodesLocalread-onlycurrentEDD Series card Port3 Detailed Link OAM Statistics: Rx Unsupported Codes
1.3.6.1.4.1.4756.20.440.20.1.318ColumneddPort3RxLinkFaultPDULocalread-onlycurrentEDD Series card Port3 Detailed Link OAM Statistics: Rx Link Fault PDU's
1.3.6.1.4.1.4756.20.440.20.1.319ColumneddPort3RxDyingGaspLocalread-onlycurrentEDD Series card Port3 Detailed Link OAM Statistics: Rx Dying Gasp
1.3.6.1.4.1.4756.20.440.20.1.320ColumneddPort3RxCriticalEventPDULocalread-onlycurrentEDD Series card Port3 Detailed Link OAM Statistics: Rx Dying Gasp
1.3.6.1.4.1.4756.20.440.20.1.321ColumneddPort3TxOAMInfoPDULocalread-onlycurrentEDD Series card Port3 Detailed Link OAM Statistics: Tx OAM Information PDU's
1.3.6.1.4.1.4756.20.440.20.1.322ColumneddPort3TxUniqueErrorEventLocalread-onlycurrentEDD Series card Port3 Detailed Link OAM Statistics: Tx Unique Error Event Notificatio
1.3.6.1.4.1.4756.20.440.20.1.323ColumneddPort3TxDuplicateErrorEventLocalread-onlycurrentEDD Series card Port3 Detailed Link OAM Statistics: Tx Duplicate Error Event Notification
1.3.6.1.4.1.4756.20.440.20.1.324ColumneddPort3TxLoopBackControlLocalread-onlycurrentEDD Series card Port3 Detailed Link OAM Statistics: Tx Loopback Control
1.3.6.1.4.1.4756.20.440.20.1.325ColumneddPort3TxVariableRequestLocalread-onlycurrentEDD Series card Port3 Detailed Link OAM Statistics: Tx Variable Request
1.3.6.1.4.1.4756.20.440.20.1.326ColumneddPort3TxVariableResponseLocalread-onlycurrentEDD Series card Port3 Detailed Link OAM Statistics: Tx Variable Response
1.3.6.1.4.1.4756.20.440.20.1.327ColumneddPort3TxOrgSpecificPDULocalread-onlycurrentEDD Series card Port3 Detailed Link OAM Statistics: Tx Org Specific PDU's
1.3.6.1.4.1.4756.20.440.20.1.328ColumneddPort3TxUnsupportedCodesLocalread-onlycurrentEDD Series card Port3 Detailed Link OAM Statistics: Tx Unsupported Codes
1.3.6.1.4.1.4756.20.440.20.1.329ColumneddPort3TxLinkFaultPDULocalread-onlycurrentEDD Series card Port3 Detailed Link OAM Statistics: Tx Link Fault PDU's
1.3.6.1.4.1.4756.20.440.20.1.330ColumneddPort3TxDyingGaspLocalread-onlycurrentEDD Series card Port3 Detailed Link OAM Statistics: Tx Dying Gasp
1.3.6.1.4.1.4756.20.440.20.1.331ColumneddPort3TxCriticalEventPDULocalread-onlycurrentEDD Series card Port3 Detailed Link OAM Statistics: Tx Dying Gasp
1.3.6.1.4.1.4756.20.440.20.1.332ColumneddPort4RxOAMInfoPDULocalread-onlycurrentEDD Series card Port4 Detailed Link OAM Statistics: Rx OAM Information PDU's
1.3.6.1.4.1.4756.20.440.20.1.333ColumneddPort4RxUniqueErrorEventLocalread-onlycurrentEDD Series card Port4 Detailed Link OAM Statistics: Rx Unique Error Event Notificatio
1.3.6.1.4.1.4756.20.440.20.1.334ColumneddPort4RxDuplicateErrorEventLocalread-onlycurrentEDD Series card Port4 Detailed Link OAM Statistics: Rx Duplicate Error Event Notification
1.3.6.1.4.1.4756.20.440.20.1.335ColumneddPort4RxLoopBackControlLocalread-onlycurrentEDD Series card Port4 Detailed Link OAM Statistics: Rx Loopback Control
1.3.6.1.4.1.4756.20.440.20.1.336ColumneddPort4RxVariableRequestLocalread-onlycurrentEDD Series card Port4 Detailed Link OAM Statistics: Rx Variable Request
1.3.6.1.4.1.4756.20.440.20.1.337ColumneddPort4RxVariableResponseLocalread-onlycurrentEDD Series card Port4 Detailed Link OAM Statistics: Rx Variable Response
1.3.6.1.4.1.4756.20.440.20.1.338ColumneddPort4RxOrgSpecificPDULocalread-onlycurrentEDD Series card Port4 Detailed Link OAM Statistics: Rx Org Specific PDU's
1.3.6.1.4.1.4756.20.440.20.1.339ColumneddPort4RxUnsupportedCodesLocalread-onlycurrentEDD Series card Port4 Detailed Link OAM Statistics: Rx Unsupported Codes
1.3.6.1.4.1.4756.20.440.20.1.340ColumneddPort4RxLinkFaultPDULocalread-onlycurrentEDD Series card Port4 Detailed Link OAM Statistics: Rx Link Fault PDU's
1.3.6.1.4.1.4756.20.440.20.1.341ColumneddPort4RxDyingGaspLocalread-onlycurrentEDD Series card Port4 Detailed Link OAM Statistics: Rx Dying Gasp
1.3.6.1.4.1.4756.20.440.20.1.342ColumneddPort4RxCriticalEventPDULocalread-onlycurrentEDD Series card Port4 Detailed Link OAM Statistics: Rx Dying Gasp
1.3.6.1.4.1.4756.20.440.20.1.343ColumneddPort4TxOAMInfoPDULocalread-onlycurrentEDD Series card Port4 Detailed Link OAM Statistics: Tx OAM Information PDU's
1.3.6.1.4.1.4756.20.440.20.1.344ColumneddPort4TxUniqueErrorEventLocalread-onlycurrentEDD Series card Port4 Detailed Link OAM Statistics: Tx Unique Error Event Notificatio
1.3.6.1.4.1.4756.20.440.20.1.345ColumneddPort4TxDuplicateErrorEventLocalread-onlycurrentEDD Series card Port4 Detailed Link OAM Statistics: Tx Duplicate Error Event Notification
1.3.6.1.4.1.4756.20.440.20.1.346ColumneddPort4TxLoopBackControlLocalread-onlycurrentEDD Series card Port4 Detailed Link OAM Statistics: Tx Loopback Control
1.3.6.1.4.1.4756.20.440.20.1.347ColumneddPort4TxVariableRequestLocalread-onlycurrentEDD Series card Port4 Detailed Link OAM Statistics: Tx Variable Request
1.3.6.1.4.1.4756.20.440.20.1.348ColumneddPort4TxVariableResponseLocalread-onlycurrentEDD Series card Port4 Detailed Link OAM Statistics: Tx Variable Response
1.3.6.1.4.1.4756.20.440.20.1.349ColumneddPort4TxOrgSpecificPDULocalread-onlycurrentEDD Series card Port4 Detailed Link OAM Statistics: Tx Org Specific PDU's
1.3.6.1.4.1.4756.20.440.20.1.350ColumneddPort4TxUnsupportedCodesLocalread-onlycurrentEDD Series card Port4 Detailed Link OAM Statistics: Tx Unsupported Codes
1.3.6.1.4.1.4756.20.440.20.1.351ColumneddPort4TxLinkFaultPDULocalread-onlycurrentEDD Series card Port4 Detailed Link OAM Statistics: Tx Link Fault PDU's
1.3.6.1.4.1.4756.20.440.20.1.352ColumneddPort4TxDyingGaspLocalread-onlycurrentEDD Series card Port4 Detailed Link OAM Statistics: Tx Dying Gasp
1.3.6.1.4.1.4756.20.440.20.1.353ColumneddPort4TxCriticalEventPDULocalread-onlycurrentEDD Series card Port4 Detailed Link OAM Statistics: Tx Dying Gasp
1.3.6.1.4.1.4756.20.440.20.1.354ColumneddPort1PDUPermisionLocalread-onlycurrentEDD Series card Detailed Link OAM Status for Port 1: PDU Permission
1.3.6.1.4.1.4756.20.440.20.1.355ColumneddPort1DiscoveryStateLocalread-onlycurrentEDD Series card Detailed Link OAM Status for Port 1: Discovery State
1.3.6.1.4.1.4756.20.440.20.1.356ColumneddPort1PeerMACAddrLocalread-onlycurrentEDD Series card Detailed Link OAM Status for Port 1: Discovery State
1.3.6.1.4.1.4756.20.440.20.1.357ColumneddPort1LocalModeLocalread-onlycurrentEDD Series card Detailed Link OAM Status for Port 1: Local: Mode
1.3.6.1.4.1.4756.20.440.20.1.358ColumneddPort1LocalUnOperationLocalread-onlycurrentEDD Series card Detailed Link OAM Status for Port 1: Local: Unidirectional Operation Support
1.3.6.1.4.1.4756.20.440.20.1.359ColumneddPort1LocalRemoteLbLocalread-onlycurrentEDD Series card Detailed Link OAM Status for Port 1: Local: Remote Loopback Support
1.3.6.1.4.1.4756.20.440.20.1.360ColumneddPort1LocalLMLocalread-onlycurrentEDD Series card Detailed Link OAM Status for Port 1: Local: Link Monitoring Support
1.3.6.1.4.1.4756.20.440.20.1.361ColumneddPort1LocalMIBRetrievalLocalread-onlycurrentEDD Series card Detailed Link OAM Status for Port 1: Local: MIB Retrieval Support
1.3.6.1.4.1.4756.20.440.20.1.362ColumneddPort1LocalMTUSizeLocalread-onlycurrentEDD Series card Detailed Link OAM Status for Port 1: Local: MTU Size
1.3.6.1.4.1.4756.20.440.20.1.363ColumneddPort1LocalMultiStateLocalread-onlycurrentEDD Series card Detailed Link OAM Status for Port 1: Local: Multiplexer State
1.3.6.1.4.1.4756.20.440.20.1.364ColumneddPort1LocalParserStateLocalread-onlycurrentEDD Series card Detailed Link OAM Status for Port 1: Local: Multiplexer State
1.3.6.1.4.1.4756.20.440.20.1.365ColumneddPort1LocalOUILocalread-onlycurrentEDD Series card Detailed Link OAM Status for Port 1: Local: Organizational Unique Identification
1.3.6.1.4.1.4756.20.440.20.1.366ColumneddPort1LocalPDURevLocalread-onlycurrentEDD Series card Detailed Link OAM Status for Port 1: Local: PDU Revision
1.3.6.1.4.1.4756.20.440.20.1.367ColumneddPort1PeerModeLocalread-onlycurrentEDD Series card Detailed Link OAM Status for Port 1: Peer: Mode
1.3.6.1.4.1.4756.20.440.20.1.368ColumneddPort1PeerUnOperationLocalread-onlycurrentEDD Series card Detailed Link OAM Status for Port 1: Peer: Unidirectional Operation Support
1.3.6.1.4.1.4756.20.440.20.1.369ColumneddPort1PeerRemoteLbLocalread-onlycurrentEDD Series card Detailed Link OAM Status for Port 1: Peer: Remote Loopback Support
1.3.6.1.4.1.4756.20.440.20.1.370ColumneddPort1PeerLMLocalread-onlycurrentEDD Series card Detailed Link OAM Status for Port 1: Peer: Link Monitoring Support
1.3.6.1.4.1.4756.20.440.20.1.371ColumneddPort1PeerMIBRetrievalLocalread-onlycurrentEDD Series card Detailed Link OAM Status for Port 1: Peer: MIB Retrieval Support
1.3.6.1.4.1.4756.20.440.20.1.372ColumneddPort1PeerMTUSizeLocalread-onlycurrentEDD Series card Detailed Link OAM Status for Port 1: Peer: MTU Size
1.3.6.1.4.1.4756.20.440.20.1.373ColumneddPort1PeerMultiStateLocalread-onlycurrentEDD Series card Detailed Link OAM Status for Port 1: Peer: Multiplexer State
1.3.6.1.4.1.4756.20.440.20.1.374ColumneddPort1PeerParserStateLocalread-onlycurrentEDD Series card Detailed Link OAM Status for Port 1: Peer: Multiplexer State
1.3.6.1.4.1.4756.20.440.20.1.375ColumneddPort1PeerOUILocalread-onlycurrentEDD Series card Detailed Link OAM Status for Port 1: Peer: Organizational Unique Identification
1.3.6.1.4.1.4756.20.440.20.1.376ColumneddPort1PeerPDURevLocalread-onlycurrentEDD Series card Detailed Link OAM Status for Port 1: Peer: PDU Revision
1.3.6.1.4.1.4756.20.440.20.1.377ColumneddPort2PDUPermisionLocalread-onlycurrentEDD Series card Detailed Link OAM Status for Port 2: PDU Permission
1.3.6.1.4.1.4756.20.440.20.1.378ColumneddPort2DiscoveryStateLocalread-onlycurrentEDD Series card Detailed Link OAM Status for Port 2: Discovery State
1.3.6.1.4.1.4756.20.440.20.1.379ColumneddPort2PeerMACAddrLocalread-onlycurrentEDD Series card Detailed Link OAM Status for Port 2: Discovery State
1.3.6.1.4.1.4756.20.440.20.1.380ColumneddPort2LocalModeLocalread-onlycurrentEDD Series card Detailed Link OAM Status for Port 2: Local: Mode
1.3.6.1.4.1.4756.20.440.20.1.381ColumneddPort2LocalUnOperationLocalread-onlycurrentEDD Series card Detailed Link OAM Status for Port 2: Local: Unidirectional Operation Support
1.3.6.1.4.1.4756.20.440.20.1.382ColumneddPort2LocalRemoteLbLocalread-onlycurrentEDD Series card Detailed Link OAM Status for Port 2: Local: Remote Loopback Support
1.3.6.1.4.1.4756.20.440.20.1.383ColumneddPort2LocalLMLocalread-onlycurrentEDD Series card Detailed Link OAM Status for Port 2: Local: Link Monitoring Support
1.3.6.1.4.1.4756.20.440.20.1.384ColumneddPort2LocalMIBRetrievalLocalread-onlycurrentEDD Series card Detailed Link OAM Status for Port 2: Local: MIB Retrieval Support
1.3.6.1.4.1.4756.20.440.20.1.385ColumneddPort2LocalMTUSizeLocalread-onlycurrentEDD Series card Detailed Link OAM Status for Port 2: Local: MTU Size
1.3.6.1.4.1.4756.20.440.20.1.386ColumneddPort2LocalMultiStateLocalread-onlycurrentEDD Series card Detailed Link OAM Status for Port 2: Local: Multiplexer State
1.3.6.1.4.1.4756.20.440.20.1.387ColumneddPort2LocalParserStateLocalread-onlycurrentEDD Series card Detailed Link OAM Status for Port 2: Local: Multiplexer State
1.3.6.1.4.1.4756.20.440.20.1.388ColumneddPort2LocalOUILocalread-onlycurrentEDD Series card Detailed Link OAM Status for Port 2: Local: Organizational Unique Identification
1.3.6.1.4.1.4756.20.440.20.1.389ColumneddPort2LocalPDURevLocalread-onlycurrentEDD Series card Detailed Link OAM Status for Port 2: Local: PDU Revision
1.3.6.1.4.1.4756.20.440.20.1.390ColumneddPort2PeerModeLocalread-onlycurrentEDD Series card Detailed Link OAM Status for Port 2: Peer: Mode
1.3.6.1.4.1.4756.20.440.20.1.391ColumneddPort2PeerUnOperationLocalread-onlycurrentEDD Series card Detailed Link OAM Status for Port 2: Peer: Unidirectional Operation Support
1.3.6.1.4.1.4756.20.440.20.1.392ColumneddPort2PeerRemoteLbLocalread-onlycurrentEDD Series card Detailed Link OAM Status for Port 2: Peer: Remote Loopback Support
1.3.6.1.4.1.4756.20.440.20.1.393ColumneddPort2PeerLMLocalread-onlycurrentEDD Series card Detailed Link OAM Status for Port 2: Peer: Link Monitoring Support
1.3.6.1.4.1.4756.20.440.20.1.394ColumneddPort2PeerMIBRetrievalLocalread-onlycurrentEDD Series card Detailed Link OAM Status for Port 2: Peer: MIB Retrieval Support
1.3.6.1.4.1.4756.20.440.20.1.395ColumneddPort2PeerMTUSizeLocalread-onlycurrentEDD Series card Detailed Link OAM Status for Port 2: Peer: MTU Size
1.3.6.1.4.1.4756.20.440.20.1.396ColumneddPort2PeerMultiStateLocalread-onlycurrentEDD Series card Detailed Link OAM Status for Port 2: Peer: Multiplexer State
1.3.6.1.4.1.4756.20.440.20.1.397ColumneddPort2PeerParserStateLocalread-onlycurrentEDD Series card Detailed Link OAM Status for Port 2: Peer: Multiplexer State
1.3.6.1.4.1.4756.20.440.20.1.398ColumneddPort2PeerOUILocalread-onlycurrentEDD Series card Detailed Link OAM Status for Port 2: Peer: Organizational Unique Identification
1.3.6.1.4.1.4756.20.440.20.1.399ColumneddPort2PeerPDURevLocalread-onlycurrentEDD Series card Detailed Link OAM Status for Port 2: Peer: PDU Revision
1.3.6.1.4.1.4756.20.440.20.1.400ColumneddPort3PDUPermisionLocalread-onlycurrentEDD Series card Detailed Link OAM Status for Port 3: PDU Permission
1.3.6.1.4.1.4756.20.440.20.1.401ColumneddPort3DiscoveryStateLocalread-onlycurrentEDD Series card Detailed Link OAM Status for Port 3: Discovery State
1.3.6.1.4.1.4756.20.440.20.1.402ColumneddPort3PeerMACAddrLocalread-onlycurrentEDD Series card Detailed Link OAM Status for Port 3: Discovery State
1.3.6.1.4.1.4756.20.440.20.1.403ColumneddPort3LocalModeLocalread-onlycurrentEDD Series card Detailed Link OAM Status for Port 3: Local: Mode
1.3.6.1.4.1.4756.20.440.20.1.404ColumneddPort3LocalUnOperationLocalread-onlycurrentEDD Series card Detailed Link OAM Status for Port 3: Local: Unidirectional Operation Support
1.3.6.1.4.1.4756.20.440.20.1.405ColumneddPort3LocalRemoteLbLocalread-onlycurrentEDD Series card Detailed Link OAM Status for Port 3: Local: Remote Loopback Support
1.3.6.1.4.1.4756.20.440.20.1.406ColumneddPort3LocalLMLocalread-onlycurrentEDD Series card Detailed Link OAM Status for Port 3: Local: Link Monitoring Support
1.3.6.1.4.1.4756.20.440.20.1.407ColumneddPort3LocalMIBRetrievalLocalread-onlycurrentEDD Series card Detailed Link OAM Status for Port 3: Local: MIB Retrieval Support
1.3.6.1.4.1.4756.20.440.20.1.408ColumneddPort3LocalMTUSizeLocalread-onlycurrentEDD Series card Detailed Link OAM Status for Port 3: Local: MTU Size
1.3.6.1.4.1.4756.20.440.20.1.409ColumneddPort3LocalMultiStateLocalread-onlycurrentEDD Series card Detailed Link OAM Status for Port 3: Local: Multiplexer State
1.3.6.1.4.1.4756.20.440.20.1.410ColumneddPort3LocalParserStateLocalread-onlycurrentEDD Series card Detailed Link OAM Status for Port 3: Local: Multiplexer State
1.3.6.1.4.1.4756.20.440.20.1.411ColumneddPort3LocalOUILocalread-onlycurrentEDD Series card Detailed Link OAM Status for Port 3: Local: Organizational Unique Identification
1.3.6.1.4.1.4756.20.440.20.1.412ColumneddPort3LocalPDURevLocalread-onlycurrentEDD Series card Detailed Link OAM Status for Port 3: Local: PDU Revision
1.3.6.1.4.1.4756.20.440.20.1.413ColumneddPort3PeerModeLocalread-onlycurrentEDD Series card Detailed Link OAM Status for Port 3: Peer: Mode
1.3.6.1.4.1.4756.20.440.20.1.414ColumneddPort3PeerUnOperationLocalread-onlycurrentEDD Series card Detailed Link OAM Status for Port 3: Peer: Unidirectional Operation Support
1.3.6.1.4.1.4756.20.440.20.1.415ColumneddPort3PeerRemoteLbLocalread-onlycurrentEDD Series card Detailed Link OAM Status for Port 3: Peer: Remote Loopback Support
1.3.6.1.4.1.4756.20.440.20.1.416ColumneddPort3PeerLMLocalread-onlycurrentEDD Series card Detailed Link OAM Status for Port 3: Peer: Link Monitoring Support
1.3.6.1.4.1.4756.20.440.20.1.417ColumneddPort3PeerMIBRetrievalLocalread-onlycurrentEDD Series card Detailed Link OAM Status for Port 3: Peer: MIB Retrieval Support
1.3.6.1.4.1.4756.20.440.20.1.418ColumneddPort3PeerMTUSizeLocalread-onlycurrentEDD Series card Detailed Link OAM Status for Port 3: Peer: MTU Size
1.3.6.1.4.1.4756.20.440.20.1.419ColumneddPort3PeerMultiStateLocalread-onlycurrentEDD Series card Detailed Link OAM Status for Port 3: Peer: Multiplexer State
1.3.6.1.4.1.4756.20.440.20.1.420ColumneddPort3PeerParserStateLocalread-onlycurrentEDD Series card Detailed Link OAM Status for Port 3: Peer: Multiplexer State
1.3.6.1.4.1.4756.20.440.20.1.421ColumneddPort3PeerOUILocalread-onlycurrentEDD Series card Detailed Link OAM Status for Port 3: Peer: Organizational Unique Identification
1.3.6.1.4.1.4756.20.440.20.1.422ColumneddPort3PeerPDURevLocalread-onlycurrentEDD Series card Detailed Link OAM Status for Port 3: Peer: PDU Revision
1.3.6.1.4.1.4756.20.440.20.1.423ColumneddPort4PDUPermisionLocalread-onlycurrentEDD Series card Detailed Link OAM Status for Port 4: PDU Permission
1.3.6.1.4.1.4756.20.440.20.1.424ColumneddPort4DiscoveryStateLocalread-onlycurrentEDD Series card Detailed Link OAM Status for Port 4: Discovery State
1.3.6.1.4.1.4756.20.440.20.1.425ColumneddPort4PeerMACAddrLocalread-onlycurrentEDD Series card Detailed Link OAM Status for Port 4: Discovery State
1.3.6.1.4.1.4756.20.440.20.1.426ColumneddPort4LocalModeLocalread-onlycurrentEDD Series card Detailed Link OAM Status for Port 4: Local: Mode
1.3.6.1.4.1.4756.20.440.20.1.427ColumneddPort4LocalUnOperationLocalread-onlycurrentEDD Series card Detailed Link OAM Status for Port 4: Local: Unidirectional Operation Support
1.3.6.1.4.1.4756.20.440.20.1.428ColumneddPort4LocalRemoteLbLocalread-onlycurrentEDD Series card Detailed Link OAM Status for Port 4: Local: Remote Loopback Support
1.3.6.1.4.1.4756.20.440.20.1.429ColumneddPort4LocalLMLocalread-onlycurrentEDD Series card Detailed Link OAM Status for Port 4: Local: Link Monitoring Support
1.3.6.1.4.1.4756.20.440.20.1.430ColumneddPort4LocalMIBRetrievalLocalread-onlycurrentEDD Series card Detailed Link OAM Status for Port 4: Local: MIB Retrieval Support
1.3.6.1.4.1.4756.20.440.20.1.431ColumneddPort4LocalMTUSizeLocalread-onlycurrentEDD Series card Detailed Link OAM Status for Port 4: Local: MTU Size
1.3.6.1.4.1.4756.20.440.20.1.432ColumneddPort4LocalMultiStateLocalread-onlycurrentEDD Series card Detailed Link OAM Status for Port 4: Local: Multiplexer State
1.3.6.1.4.1.4756.20.440.20.1.433ColumneddPort4LocalParserStateLocalread-onlycurrentEDD Series card Detailed Link OAM Status for Port 4: Local: Multiplexer State
1.3.6.1.4.1.4756.20.440.20.1.434ColumneddPort4LocalOUILocalread-onlycurrentEDD Series card Detailed Link OAM Status for Port 4: Local: Organizational Unique Identification
1.3.6.1.4.1.4756.20.440.20.1.435ColumneddPort4LocalPDURevLocalread-onlycurrentEDD Series card Detailed Link OAM Status for Port 4: Local: PDU Revision
1.3.6.1.4.1.4756.20.440.20.1.436ColumneddPort4PeerModeLocalread-onlycurrentEDD Series card Detailed Link OAM Status for Port 4: Peer: Mode
1.3.6.1.4.1.4756.20.440.20.1.437ColumneddPort4PeerUnOperationLocalread-onlycurrentEDD Series card Detailed Link OAM Status for Port 4: Peer: Unidirectional Operation Support
1.3.6.1.4.1.4756.20.440.20.1.438ColumneddPort4PeerRemoteLbLocalread-onlycurrentEDD Series card Detailed Link OAM Status for Port 4: Peer: Remote Loopback Support
1.3.6.1.4.1.4756.20.440.20.1.439ColumneddPort4PeerLMLocalread-onlycurrentEDD Series card Detailed Link OAM Status for Port 4: Peer: Link Monitoring Support
1.3.6.1.4.1.4756.20.440.20.1.440ColumneddPort4PeerMIBRetrievalLocalread-onlycurrentEDD Series card Detailed Link OAM Status for Port 4: Peer: MIB Retrieval Support
1.3.6.1.4.1.4756.20.440.20.1.441ColumneddPort4PeerMTUSizeLocalread-onlycurrentEDD Series card Detailed Link OAM Status for Port 4: Peer: MTU Size
1.3.6.1.4.1.4756.20.440.20.1.442ColumneddPort4PeerMultiStateLocalread-onlycurrentEDD Series card Detailed Link OAM Status for Port 4: Peer: Multiplexer State
1.3.6.1.4.1.4756.20.440.20.1.443ColumneddPort4PeerParserStateLocalread-onlycurrentEDD Series card Detailed Link OAM Status for Port 4: Peer: Multiplexer State
1.3.6.1.4.1.4756.20.440.20.1.444ColumneddPort4PeerOUILocalread-onlycurrentEDD Series card Detailed Link OAM Status for Port 4: Peer: Organizational Unique Identification
1.3.6.1.4.1.4756.20.440.20.1.445ColumneddPort4PeerPDURevLocalread-onlycurrentEDD Series card Detailed Link OAM Status for Port 4: Peer: PDU Revision
1.3.6.1.4.1.4756.20.440.20.1.446ColumneddCLEAROAMCOUNTERLocalread-writecurrentEDD Series card Clear OAM Counter: 0: Off 1: Action
1.3.6.1.4.1.4756.20.440.20.1.447ColumneddLoopProtectionEnableLocalread-writecurrentEDD Series card Loop Protection Configuration: General Settings - Enable Loop Protection 0: Disable 1: Enable
1.3.6.1.4.1.4756.20.440.20.1.448ColumneddLoopProtectionTxTimeLocalread-writecurrentEDD Series card Loop Protection Configuration: General Settings - Transmission Time
1.3.6.1.4.1.4756.20.440.20.1.449ColumneddLoopProtectionShutdownTimeLocalread-writecurrentEDD Series card Loop Protection Configuration: General Settings - Shutdown Time
1.3.6.1.4.1.4756.20.440.20.1.450ColumneddLoopProtectionPort1EnabledLocalread-writecurrentEDD Series card Loop Protection Configuration for Port 1: Port Configuration - Enable 0: Disable 1: Enable
1.3.6.1.4.1.4756.20.440.20.1.451ColumneddLoopProtectionPort1ActionLocalread-writecurrentEDD Series card Loop Protection Configuration for Port 1: Port Configuration - Action 0: Shutdown Port 1: Shutdown Port And Log 2: Log Only
1.3.6.1.4.1.4756.20.440.20.1.452ColumneddLoopProtectionPort1TxModeLocalread-writecurrentEDD Series card Loop Protection Configuration for Port 1: Port Configuration - Tx Mode 0: Disable 1: Enable
1.3.6.1.4.1.4756.20.440.20.1.453ColumneddLoopProtectionPort2EnabledLocalread-writecurrentEDD Series card Loop Protection Configuration for Port 2: Port Configuration - Enable 0: Disable 1: Enable
1.3.6.1.4.1.4756.20.440.20.1.454ColumneddLoopProtectionPort2ActionLocalread-writecurrentEDD Series card Loop Protection Configuration for Port 2: Port Configuration - Action 0: Shutdown Port 1: Shutdown Port And Log 2: Log Only
1.3.6.1.4.1.4756.20.440.20.1.455ColumneddLoopProtectionPort2TxModeLocalread-writecurrentEDD Series card Loop Protection Configuration for Port 2: Port Configuration - Tx Mode 0: Disable 1: Enable
1.3.6.1.4.1.4756.20.440.20.1.456ColumneddLoopProtectionPort3EnabledLocalread-writecurrentEDD Series card Loop Protection Configuration for Port 3: Port Configuration - Enable 0: Disable 1: Enable
1.3.6.1.4.1.4756.20.440.20.1.457ColumneddLoopProtectionPort3ActionLocalread-writecurrentEDD Series card Loop Protection Configuration for Port 3: Port Configuration - Action 0: Shutdown Port 1: Shutdown Port And Log 2: Log Only
1.3.6.1.4.1.4756.20.440.20.1.458ColumneddLoopProtectionPort3TxModeLocalread-writecurrentEDD Series card Loop Protection Configuration for Port 3: Port Configuration - Tx Mode 0: Disable 1: Enable
1.3.6.1.4.1.4756.20.440.20.1.459ColumneddLoopProtectionPort4EnabledLocalread-writecurrentEDD Series card Loop Protection Configuration for Port 4: Port Configuration - Enable 0: Disable 1: Enable
1.3.6.1.4.1.4756.20.440.20.1.460ColumneddLoopProtectionPort4ActionLocalread-writecurrentEDD Series card Loop Protection Configuration for Port 4: Port Configuration - Action 0: Shutdown Port 1: Shutdown Port And Log 2: Log Only
1.3.6.1.4.1.4756.20.440.20.1.461ColumneddLoopProtectionPort4TxModeLocalread-writecurrentEDD Series card Loop Protection Configuration for Port 41: Port Configuration - Tx Mode 0: Disable 1: Enable
1.3.6.1.4.1.4756.20.440.20.1.462ColumneddLoopProtectionPort1ActionStsLocalread-onlycurrentEDD Series card Loop Protection Status for Port 1: Action
1.3.6.1.4.1.4756.20.440.20.1.463ColumneddLoopProtectionPort1TransStsLocalread-onlycurrentEDD Series card Loop Protection Status for Port 1: Transmit
1.3.6.1.4.1.4756.20.440.20.1.464ColumneddLoopProtectionPort1LoopsStsLocalread-onlycurrentEDD Series card Loop Protection Status for Port 1: Loops
1.3.6.1.4.1.4756.20.440.20.1.465ColumneddLoopProtectionPort1StatusLocalread-onlycurrentEDD Series card Loop Protection Status for Port 1: Status
1.3.6.1.4.1.4756.20.440.20.1.466ColumneddLoopProtectionPort1LoopStsLocalread-onlycurrentEDD Series card Loop Protection Status for Port 1: Loop
1.3.6.1.4.1.4756.20.440.20.1.467ColumneddLoopProtectionPort1TimeOfLastLoopLocalread-onlycurrentEDD Series card Loop Protection Status for Port 1: Time of Last Loop
1.3.6.1.4.1.4756.20.440.20.1.468ColumneddLoopProtectionPort2ActionStsLocalread-onlycurrentEDD Series card Loop Protection Status for Port 2: Action
1.3.6.1.4.1.4756.20.440.20.1.469ColumneddLoopProtectionPort2TransStsLocalread-onlycurrentEDD Series card Loop Protection Status for Port 2: Transmit
1.3.6.1.4.1.4756.20.440.20.1.470ColumneddLoopProtectionPort2LoopsStsLocalread-onlycurrentEDD Series card Loop Protection Status for Port 2: Loops
1.3.6.1.4.1.4756.20.440.20.1.471ColumneddLoopProtectionPort2StatusLocalread-onlycurrentEDD Series card Loop Protection Status for Port 2: Status
1.3.6.1.4.1.4756.20.440.20.1.472ColumneddLoopProtectionPort2LoopStsLocalread-onlycurrentEDD Series card Loop Protection Status for Port 2: Loop
1.3.6.1.4.1.4756.20.440.20.1.473ColumneddLoopProtectionPort2TimeOfLastLoopLocalread-onlycurrentEDD Series card Loop Protection Status for Port 2: Time of Last Loop
1.3.6.1.4.1.4756.20.440.20.1.474ColumneddLoopProtectionPort3ActionStsLocalread-onlycurrentEDD Series card Loop Protection Status for Port 3: Action
1.3.6.1.4.1.4756.20.440.20.1.475ColumneddLoopProtectionPort3TransStsLocalread-onlycurrentEDD Series card Loop Protection Status for Port 3: Transmit
1.3.6.1.4.1.4756.20.440.20.1.476ColumneddLoopProtectionPort3LoopsStsLocalread-onlycurrentEDD Series card Loop Protection Status for Port 3: Loops
1.3.6.1.4.1.4756.20.440.20.1.477ColumneddLoopProtectionPort3StatusLocalread-onlycurrentEDD Series card Loop Protection Status for Port 3: Status
1.3.6.1.4.1.4756.20.440.20.1.478ColumneddLoopProtectionPort3LoopStsLocalread-onlycurrentEDD Series card Loop Protection Status for Port 3: Loop
1.3.6.1.4.1.4756.20.440.20.1.479ColumneddLoopProtectionPort3TimeOfLastLoopLocalread-onlycurrentEDD Series card Loop Protection Status for Port 3: Time of Last Loop
1.3.6.1.4.1.4756.20.440.20.1.480ColumneddLoopProtectionPort4ActionStsLocalread-onlycurrentEDD Series card Loop Protection Status for Port 4: Action
1.3.6.1.4.1.4756.20.440.20.1.481ColumneddLoopProtectionPort4TransStsLocalread-onlycurrentEDD Series card Loop Protection Status for Port 4: Transmit
1.3.6.1.4.1.4756.20.440.20.1.482ColumneddLoopProtectionPort4LoopsStsLocalread-onlycurrentEDD Series card Loop Protection Status for Port 4: Loops
1.3.6.1.4.1.4756.20.440.20.1.483ColumneddLoopProtectionPort4StatusLocalread-onlycurrentEDD Series card Loop Protection Status for Port 4: Status
1.3.6.1.4.1.4756.20.440.20.1.484ColumneddLoopProtectionPort4LoopStsLocalread-onlycurrentEDD Series card Loop Protection Status for Port 4: Loop
1.3.6.1.4.1.4756.20.440.20.1.485ColumneddLoopProtectionPort4TimeOfLastLoopLocalread-onlycurrentEDD Series card Loop Protection Status for Port 4: Time of Last Loop
1.3.6.1.4.1.4756.20.440.20.1.486ColumneddSTPProtocolVersionLocalread-writecurrentEDD Series card STP Bridge Configuration: Basic Settings - Protocol Version 0: STP 1: RSTP 2: MSTP
1.3.6.1.4.1.4756.20.440.20.1.487ColumneddSTPBridgePriorityLocalread-writecurrentEDD Series card STP Bridge Configuration: Basic Settings - Bridge Priority 0: 0 1: 4096 2: 8192 3: 12288 4: 16384 5: 20480 6: 24576 7: 28672 8: 32768 9: 36864 …
1.3.6.1.4.1.4756.20.440.20.1.488ColumneddSTPForwardDelayLocalread-writecurrentEDD Series card STP Bridge Configuration: Basic Settings - Forward Delay
1.3.6.1.4.1.4756.20.440.20.1.489ColumneddSTPMaxAgeLocalread-writecurrentEDD Series card STP Bridge Configuration: Basic Settings - Max Age
1.3.6.1.4.1.4756.20.440.20.1.490ColumneddSTPMaximumHopCountLocalread-writecurrentEDD Series card STP Bridge Configuration: Basic Settings - Maximum Hop Count
1.3.6.1.4.1.4756.20.440.20.1.491ColumneddSTPTransmitHoldCountLocalread-writecurrentEDD Series card STP Bridge Configuration: Basic Settings - Transmit Hold Count
1.3.6.1.4.1.4756.20.440.20.1.492ColumneddSTPEdgePortBPDUFilteringLocalread-writecurrentEDD Series card STP Bridge Configuration: Advanced Settings - Edge Port BPDU Filtering 0: Off 1: On
1.3.6.1.4.1.4756.20.440.20.1.493ColumneddSTPEdgePortBPDUGuardLocalread-writecurrentEDD Series card STP Bridge Configuration: Advanced Settings - Edge Port BPDU Guard 0: Off 1: On
1.3.6.1.4.1.4756.20.440.20.1.494ColumneddSTPPortErrorRecoveryTimeoutLocalread-writecurrentEDD Series card STP Bridge Configuration: Advanced Settings - Port Error Recovery Timeout 0: Off 1: On
1.3.6.1.4.1.4756.20.440.20.1.495ColumneddMSTIConfigurationNameLocalread-writecurrentEDD Series card MSTI Configuration: Configuration Identification - Configuration Name
1.3.6.1.4.1.4756.20.440.20.1.496ColumneddMSTIConfigurationRevisionLocalread-writecurrentEDD Series card MSTI Configuration: Configuration Identification - Configuration Revision
1.3.6.1.4.1.4756.20.440.20.1.497ColumneddMSTI1VLANsMappingLocalread-writecurrentEDD Series card MSTI Configuration: MSTI Mapping - MSTI 1
1.3.6.1.4.1.4756.20.440.20.1.498ColumneddMSTI2VLANsMappingLocalread-writecurrentEDD Series card MSTI Configuration: MSTI Mapping - MSTI 2
1.3.6.1.4.1.4756.20.440.20.1.499ColumneddMSTI3VLANsMappingLocalread-writecurrentEDD Series card MSTI Configuration: MSTI Mapping - MSTI 3
1.3.6.1.4.1.4756.20.440.20.1.500ColumneddMSTI4VLANsMappingLocalread-writecurrentEDD Series card MSTI Configuration: MSTI Mapping - MSTI 4
1.3.6.1.4.1.4756.20.440.20.1.501ColumneddMSTI5VLANsMappingLocalread-writecurrentEDD Series card MSTI Configuration: MSTI Mapping - MSTI 5
1.3.6.1.4.1.4756.20.440.20.1.502ColumneddMSTI6VLANsMappingLocalread-writecurrentEDD Series card MSTI Configuration: MSTI Mapping - MSTI 6
1.3.6.1.4.1.4756.20.440.20.1.503ColumneddMSTI7VLANsMappingLocalread-writecurrentEDD Series card MSTI Configuration: MSTI Mapping - MSTI 7
1.3.6.1.4.1.4756.20.440.20.1.504ColumneddCISTAggregatedSTPEnabledLocalread-writecurrentEDD Series card STP CIST Port Configuration: CIST Aggregated Port Configuration - STP Enabled
1.3.6.1.4.1.4756.20.440.20.1.505ColumneddCISTAggregatedPathCostLocalread-writecurrentEDD Series card STP CIST Port Configuration: CIST Aggregated Port Configuration - Path Cost Valid values are in the range 0 to 200000000. Setting 0 means Auto …
1.3.6.1.4.1.4756.20.440.20.1.506ColumneddCISTAggregatedPriorityLocalread-writecurrentEDD Series card STP CIST Port Configuration: CIST Aggregated Port Configuration - Priority
1.3.6.1.4.1.4756.20.440.20.1.507ColumneddCISTAggregatedAdminEdgeLocalread-writecurrentEDD Series card STP CIST Port Configuration: CIST Aggregated Port Configuration - STP Enabled 0: Non-edge 1: Edge
1.3.6.1.4.1.4756.20.440.20.1.508ColumneddCISTAggregatedAutoEdgeLocalread-writecurrentEDD Series card STP CIST Port Configuration: CIST Aggregated Port Configuration - Auto Edge 0: Non-edge 1: Edge
1.3.6.1.4.1.4756.20.440.20.1.509ColumneddCISTAggregatedRestrictedRoleLocalread-writecurrentEDD Series card STP CIST Port Configuration: CIST Aggregated Port Configuration - Restricted Role 0: Non-edge 1: Edge
1.3.6.1.4.1.4756.20.440.20.1.510ColumneddCISTAggregatedRestrictedTCNLocalread-writecurrentEDD Series card STP CIST Port Configuration: CIST Aggregated Port Configuration - Restricted TCN 0: Non-edge 1: Edge
1.3.6.1.4.1.4756.20.440.20.1.511ColumneddCISTAggregatedBPDUGuardLocalread-writecurrentEDD Series card STP CIST Port Configuration: CIST Aggregated Port Configuration - BPDU Guard 0: Non-edge 1: Edge
1.3.6.1.4.1.4756.20.440.20.1.512ColumneddCISTAggregatedPointToPointLocalread-writecurrentEDD Series card STP CIST Port Configuration: CIST Aggregated Port Configuration - Point-to-point 0: Forced True 1: Forced False 2: Auto
1.3.6.1.4.1.4756.20.440.20.1.513ColumneddCISTPort1STPEnabledLocalread-writecurrentEDD Series card STP CIST Port Configuration: CIST Normal Port1 Configuration - STP Enabled
1.3.6.1.4.1.4756.20.440.20.1.514ColumneddCISTPort1PathCostLocalread-writecurrentEDD Series card STP CIST Port Configuration: CIST Normal Port1 Configuration - Path Cost Valid values are in the range 0 to 200000000. Setting 0 means Auto pat…
1.3.6.1.4.1.4756.20.440.20.1.515ColumneddCISTPort1PriorityLocalread-writecurrentEDD Series card STP CIST Port Configuration: CIST Normal Port1 Configuration - Priority
1.3.6.1.4.1.4756.20.440.20.1.516ColumneddCISTPort1AdminEdgeLocalread-writecurrentEDD Series card STP CIST Port Configuration: CIST Normal Port1 Configuration - STP Enabled 0: Non-edge 1: Edge
1.3.6.1.4.1.4756.20.440.20.1.517ColumneddCISTPort1AutoEdgeLocalread-writecurrentEDD Series card STP CIST Port Configuration: CIST Normal Port1 Configuration - Auto Edge 0: Non-edge 1: Edge
1.3.6.1.4.1.4756.20.440.20.1.518ColumneddCISTPort1RestrictedRoleLocalread-writecurrentEDD Series card STP CIST Port Configuration: CIST Normal Port1 Configuration - Restricted Role 0: Non-edge 1: Edge
1.3.6.1.4.1.4756.20.440.20.1.519ColumneddCISTPort1RestrictedTCNLocalread-writecurrentEDD Series card STP CIST Port Configuration: CIST Normal Port1 Configuration - Restricted TCN 0: Non-edge 1: Edge
1.3.6.1.4.1.4756.20.440.20.1.520ColumneddCISTPort1BPDUGuardLocalread-writecurrentEDD Series card STP CIST Port Configuration: CIST Normal Port1 Configuration - BPDU Guard 0: Non-edge 1: Edge
1.3.6.1.4.1.4756.20.440.20.1.521ColumneddCISTPort1PointToPointLocalread-writecurrentEDD Series card STP CIST Port Configuration: CIST Normal Port1 Configuration - Point-to-point 0: Forced True 1: Forced False 2: Auto
1.3.6.1.4.1.4756.20.440.20.1.522ColumneddCISTPort2STPEnabledLocalread-writecurrentEDD Series card STP CIST Port Configuration: CIST Normal Port2 Configuration - STP Enabled
1.3.6.1.4.1.4756.20.440.20.1.523ColumneddCISTPort2PathCostLocalread-writecurrentEDD Series card STP CIST Port Configuration: CIST Normal Port2 Configuration - Path Cost Valid values are in the range 0 to 200000000. Setting 0 means Auto pat…
1.3.6.1.4.1.4756.20.440.20.1.524ColumneddCISTPort2PriorityLocalread-writecurrentEDD Series card STP CIST Port Configuration: CIST Normal Port2 Configuration - Priority
1.3.6.1.4.1.4756.20.440.20.1.525ColumneddCISTPort2AdminEdgeLocalread-writecurrentEDD Series card STP CIST Port Configuration: CIST Normal Port2 Configuration - STP Enabled 0: Non-edge 1: Edge
1.3.6.1.4.1.4756.20.440.20.1.526ColumneddCISTPort2AutoEdgeLocalread-writecurrentEDD Series card STP CIST Port Configuration: CIST Normal Port2 Configuration - Auto Edge 0: Non-edge 1: Edge
1.3.6.1.4.1.4756.20.440.20.1.527ColumneddCISTPort2RestrictedRoleLocalread-writecurrentEDD Series card STP CIST Port Configuration: CIST Normal Port2 Configuration - Restricted Role 0: Non-edge 1: Edge
1.3.6.1.4.1.4756.20.440.20.1.528ColumneddCISTPort2RestrictedTCNLocalread-writecurrentEDD Series card STP CIST Port Configuration: CIST Normal Port2 Configuration - Restricted TCN 0: Non-edge 1: Edge
1.3.6.1.4.1.4756.20.440.20.1.529ColumneddCISTPort2BPDUGuardLocalread-writecurrentEDD Series card STP CIST Port Configuration: CIST Normal Port2 Configuration - BPDU Guard 0: Non-edge 1: Edge
1.3.6.1.4.1.4756.20.440.20.1.530ColumneddCISTPort2PointToPointLocalread-writecurrentEDD Series card STP CIST Port Configuration: CIST Normal Port2 Configuration - Point-to-point 0: Forced True 1: Forced False 2: Auto
1.3.6.1.4.1.4756.20.440.20.1.531ColumneddCISTPort3STPEnabledLocalread-writecurrentEDD Series card STP CIST Port Configuration: CIST Normal Port3 Configuration - STP Enabled
1.3.6.1.4.1.4756.20.440.20.1.532ColumneddCISTPort3PathCostLocalread-writecurrentEDD Series card STP CIST Port Configuration: CIST Normal Port3 Configuration - Path Cost Valid values are in the range 0 to 200000000. Setting 0 means Auto pat…
1.3.6.1.4.1.4756.20.440.20.1.533ColumneddCISTPort3PriorityLocalread-writecurrentEDD Series card STP CIST Port Configuration: CIST Normal Port3 Configuration - Priority
1.3.6.1.4.1.4756.20.440.20.1.534ColumneddCISTPort3AdminEdgeLocalread-writecurrentEDD Series card STP CIST Port Configuration: CIST Normal Port3 Configuration - STP Enabled 0: Non-edge 1: Edge
1.3.6.1.4.1.4756.20.440.20.1.535ColumneddCISTPort3AutoEdgeLocalread-writecurrentEDD Series card STP CIST Port Configuration: CIST Normal Port3 Configuration - Auto Edge 0: Non-edge 1: Edge
1.3.6.1.4.1.4756.20.440.20.1.536ColumneddCISTPort3RestrictedRoleLocalread-writecurrentEDD Series card STP CIST Port Configuration: CIST Normal Port3 Configuration - Restricted Role 0: Non-edge 1: Edge
1.3.6.1.4.1.4756.20.440.20.1.537ColumneddCISTPort3RestrictedTCNLocalread-writecurrentEDD Series card STP CIST Port Configuration: CIST Normal Port3 Configuration - Restricted TCN 0: Non-edge 1: Edge
1.3.6.1.4.1.4756.20.440.20.1.538ColumneddCISTPort3BPDUGuardLocalread-writecurrentEDD Series card STP CIST Port Configuration: CIST Normal Port3 Configuration - BPDU Guard 0: Non-edge 1: Edge
1.3.6.1.4.1.4756.20.440.20.1.539ColumneddCISTPort3PointToPointLocalread-writecurrentEDD Series card STP CIST Port Configuration: CIST Normal Port3 Configuration - Point-to-point 0: Forced True 1: Forced False 2: Auto
1.3.6.1.4.1.4756.20.440.20.1.540ColumneddCISTPort4STPEnabledLocalread-writecurrentEDD Series card STP CIST Port Configuration: CIST Normal Port4 Configuration - STP Enabled
1.3.6.1.4.1.4756.20.440.20.1.541ColumneddCISTPort4PathCostLocalread-writecurrentEDD Series card STP CIST Port Configuration: CIST Normal Port4 Configuration - Path Cost Valid values are in the range 0 to 200000000. Setting 0 means Auto pat…
1.3.6.1.4.1.4756.20.440.20.1.542ColumneddCISTPort4PriorityLocalread-writecurrentEDD Series card STP CIST Port Configuration: CIST Normal Port4 Configuration - Priority
1.3.6.1.4.1.4756.20.440.20.1.543ColumneddCISTPort4AdminEdgeLocalread-writecurrentEDD Series card STP CIST Port Configuration: CIST Normal Port4 Configuration - STP Enabled 0: Non-edge 1: Edge
1.3.6.1.4.1.4756.20.440.20.1.544ColumneddCISTPort4AutoEdgeLocalread-writecurrentEDD Series card STP CIST Port Configuration: CIST Normal Port4 Configuration - Auto Edge 0: Non-edge 1: Edge
1.3.6.1.4.1.4756.20.440.20.1.545ColumneddCISTPort4RestrictedRoleLocalread-writecurrentEDD Series card STP CIST Port Configuration: CIST Normal Port4 Configuration - Restricted Role 0: Non-edge 1: Edge
1.3.6.1.4.1.4756.20.440.20.1.546ColumneddCISTPort4RestrictedTCNLocalread-writecurrentEDD Series card STP CIST Port Configuration: CIST Normal Port4 Configuration - Restricted TCN 0: Non-edge 1: Edge
1.3.6.1.4.1.4756.20.440.20.1.547ColumneddCISTPort4BPDUGuardLocalread-writecurrentEDD Series card STP CIST Port Configuration: CIST Normal Port4 Configuration - BPDU Guard 0: Non-edge 1: Edge
1.3.6.1.4.1.4756.20.440.20.1.548ColumneddCISTPort4PointToPointLocalread-writecurrentEDD Series card STP CIST Port Configuration: CIST Normal Port4 Configuration - Point-to-point 0: Forced True 1: Forced False 2: Auto
1.3.6.1.4.1.4756.20.440.20.1.549ColumneddMSTI1AggregatedPathCostLocalread-writecurrentEDD Series card MSTI Port Configuration: MSTI1 Aggregated Ports Configuration - Path Cost Valid values are in the range 0 to 200000000. Setting 0 means Auto pa…
1.3.6.1.4.1.4756.20.440.20.1.550ColumneddMSTI1AggregatedPriorityLocalread-writecurrentEDD Series card MSTI Port Configuration: MSTI1 Aggregated Ports Configuration - Priority
1.3.6.1.4.1.4756.20.440.20.1.551ColumneddMSTI1Port1PathCostLocalread-writecurrentEDD Series card MSTI Port Configuration: MSTI1 Normal Port1 Configuration - Path Cost Valid values are in the range 0 to 200000000. Setting 0 means Auto path c…
1.3.6.1.4.1.4756.20.440.20.1.552ColumneddMSTI1Port1PriorityLocalread-writecurrentEDD Series card MSTI Port Configuration: MSTI1 Normal Port1 Configuration - Priority
1.3.6.1.4.1.4756.20.440.20.1.553ColumneddMSTI1Port2PathCostLocalread-writecurrentEDD Series card MSTI Port Configuration: MSTI1 Normal Port2 Configuration - Path Cost Valid values are in the range 0 to 200000000. Setting 0 means Auto path c…
1.3.6.1.4.1.4756.20.440.20.1.554ColumneddMSTI1Port2PriorityLocalread-writecurrentEDD Series card MSTI Port Configuration: MSTI1 Normal Port2 Configuration - Priority
1.3.6.1.4.1.4756.20.440.20.1.555ColumneddMSTI1Port3PathCostLocalread-writecurrentEDD Series card MSTI Port Configuration: MSTI1 Normal Port3 Configuration - Path Cost Valid values are in the range 0 to 200000000. Setting 0 means Auto path c…
1.3.6.1.4.1.4756.20.440.20.1.556ColumneddMSTI1Port3PriorityLocalread-writecurrentEDD Series card MSTI Port Configuration: MSTI1 Normal Port3 Configuration - Priority
1.3.6.1.4.1.4756.20.440.20.1.557ColumneddMSTI1Port4PathCostLocalread-writecurrentEDD Series card MSTI Port Configuration: MSTI1 Normal Port4 Configuration - Path Cost Valid values are in the range 0 to 200000000. Setting 0 means Auto path c…
1.3.6.1.4.1.4756.20.440.20.1.558ColumneddMSTI1Port4PriorityLocalread-writecurrentEDD Series card MSTI Port Configuration: MSTI1 Normal Port4 Configuration - Priority
1.3.6.1.4.1.4756.20.440.20.1.559ColumneddMSTI2AggregatedPathCostLocalread-writecurrentEDD Series card MSTI Port Configuration: MSTI2 Aggregated Ports Configuration - Path Cost Valid values are in the range 0 to 200000000. Setting 0 means Auto pa…
1.3.6.1.4.1.4756.20.440.20.1.560ColumneddMSTI2AggregatedPriorityLocalread-writecurrentEDD Series card MSTI Port Configuration: MSTI2 Aggregated Ports Configuration - Priority
1.3.6.1.4.1.4756.20.440.20.1.561ColumneddMSTI2Port1PathCostLocalread-writecurrentEDD Series card MSTI Port Configuration: MSTI2 Normal Port1 Configuration - Path Cost Valid values are in the range 0 to 200000000. Setting 0 means Auto path c…
1.3.6.1.4.1.4756.20.440.20.1.562ColumneddMSTI2Port1PriorityLocalread-writecurrentEDD Series card MSTI Port Configuration: MSTI2 Normal Port1 Configuration - Priority
1.3.6.1.4.1.4756.20.440.20.1.563ColumneddMSTI2Port2PathCostLocalread-writecurrentEDD Series card MSTI Port Configuration: MSTI2 Normal Port2 Configuration - Path Cost Valid values are in the range 0 to 200000000. Setting 0 means Auto path c…
1.3.6.1.4.1.4756.20.440.20.1.564ColumneddMSTI2Port2PriorityLocalread-writecurrentEDD Series card MSTI Port Configuration: MSTI2 Normal Port2 Configuration - Priority
1.3.6.1.4.1.4756.20.440.20.1.565ColumneddMSTI2Port3PathCostLocalread-writecurrentEDD Series card MSTI Port Configuration: MSTI2 Normal Port3 Configuration - Path Cost Valid values are in the range 0 to 200000000. Setting 0 means Auto path c…
1.3.6.1.4.1.4756.20.440.20.1.566ColumneddMSTI2Port3PriorityLocalread-writecurrentEDD Series card MSTI Port Configuration: MSTI2 Normal Port3 Configuration - Priority
1.3.6.1.4.1.4756.20.440.20.1.567ColumneddMSTI2Port4PathCostLocalread-writecurrentEDD Series card MSTI Port Configuration: MSTI2 Normal Port4 Configuration - Path Cost Valid values are in the range 0 to 200000000. Setting 0 means Auto path c…
1.3.6.1.4.1.4756.20.440.20.1.568ColumneddMSTI2Port4PriorityLocalread-writecurrentEDD Series card MSTI Port Configuration: MSTI2 Normal Port4 Configuration - Priority
1.3.6.1.4.1.4756.20.440.20.1.569ColumneddMSTI3AggregatedPathCostLocalread-writecurrentEDD Series card MSTI Port Configuration: MSTI3 Aggregated Ports Configuration - Path Cost Valid values are in the range 0 to 200000000. Setting 0 means Auto pa…
1.3.6.1.4.1.4756.20.440.20.1.570ColumneddMSTI3AggregatedPriorityLocalread-writecurrentEDD Series card MSTI Port Configuration: MSTI3 Aggregated Ports Configuration - Priority
1.3.6.1.4.1.4756.20.440.20.1.571ColumneddMSTI3Port1PathCostLocalread-writecurrentEDD Series card MSTI Port Configuration: MSTI3 Normal Port1 Configuration - Path Cost Valid values are in the range 0 to 200000000. Setting 0 means Auto path c…
1.3.6.1.4.1.4756.20.440.20.1.572ColumneddMSTI3Port1PriorityLocalread-writecurrentEDD Series card MSTI Port Configuration: MSTI3 Normal Port1 Configuration - Priority
1.3.6.1.4.1.4756.20.440.20.1.573ColumneddMSTI3Port2PathCostLocalread-writecurrentEDD Series card MSTI Port Configuration: MSTI3 Normal Port2 Configuration - Path Cost Valid values are in the range 0 to 200000000. Setting 0 means Auto path c…
1.3.6.1.4.1.4756.20.440.20.1.574ColumneddMSTI3Port2PriorityLocalread-writecurrentEDD Series card MSTI Port Configuration: MSTI3 Normal Port2 Configuration - Priority
1.3.6.1.4.1.4756.20.440.20.1.575ColumneddMSTI3Port3PathCostLocalread-writecurrentEDD Series card MSTI Port Configuration: MSTI1 Normal Port3 Configuration - Path Cost Valid values are in the range 0 to 200000000. Setting 0 means Auto path c…
1.3.6.1.4.1.4756.20.440.20.1.576ColumneddMSTI3Port3PriorityLocalread-writecurrentEDD Series card MSTI Port Configuration: MSTI3 Normal Port3 Configuration - Priority
1.3.6.1.4.1.4756.20.440.20.1.577ColumneddMSTI3Port4PathCostLocalread-writecurrentEDD Series card MSTI Port Configuration: MSTI3 Normal Port4 Configuration - Path Cost Valid values are in the range 0 to 200000000. Setting 0 means Auto path c…
1.3.6.1.4.1.4756.20.440.20.1.578ColumneddMSTI3Port4PriorityLocalread-writecurrentEDD Series card MSTI Port Configuration: MSTI3 Normal Port4 Configuration - Priority
1.3.6.1.4.1.4756.20.440.20.1.579ColumneddMSTI4AggregatedPathCostLocalread-writecurrentEDD Series card MSTI Port Configuration: MSTI4 Aggregated Ports Configuration - Path Cost Valid values are in the range 0 to 200000000. Setting 0 means Auto pa…
1.3.6.1.4.1.4756.20.440.20.1.580ColumneddMSTI4AggregatedPriorityLocalread-writecurrentEDD Series card MSTI Port Configuration: MSTI4 Aggregated Ports Configuration - Priority
1.3.6.1.4.1.4756.20.440.20.1.581ColumneddMSTI4Port1PathCostLocalread-writecurrentEDD Series card MSTI Port Configuration: MSTI4 Normal Port1 Configuration - Path Cost Valid values are in the range 0 to 200000000. Setting 0 means Auto path c…
1.3.6.1.4.1.4756.20.440.20.1.582ColumneddMSTI4Port1PriorityLocalread-writecurrentEDD Series card MSTI Port Configuration: MSTI4 Normal Port1 Configuration - Priority
1.3.6.1.4.1.4756.20.440.20.1.583ColumneddMSTI4Port2PathCostLocalread-writecurrentEDD Series card MSTI Port Configuration: MSTI4 Normal Port2 Configuration - Path Cost Valid values are in the range 0 to 200000000. Setting 0 means Auto path c…
1.3.6.1.4.1.4756.20.440.20.1.584ColumneddMSTI4Port2PriorityLocalread-writecurrentEDD Series card MSTI Port Configuration: MSTI4 Normal Port2 Configuration - Priority
1.3.6.1.4.1.4756.20.440.20.1.585ColumneddMSTI4Port3PathCostLocalread-writecurrentEDD Series card MSTI Port Configuration: MSTI1 Normal Port3 Configuration - Path Cost Valid values are in the range 0 to 200000000. Setting 0 means Auto path c…
1.3.6.1.4.1.4756.20.440.20.1.586ColumneddMSTI4Port3PriorityLocalread-writecurrentEDD Series card MSTI Port Configuration: MSTI4 Normal Port3 Configuration - Priority
1.3.6.1.4.1.4756.20.440.20.1.587ColumneddMSTI4Port4PathCostLocalread-writecurrentEDD Series card MSTI Port Configuration: MSTI4 Normal Port4 Configuration - Path Cost Valid values are in the range 0 to 200000000. Setting 0 means Auto path c…
1.3.6.1.4.1.4756.20.440.20.1.588ColumneddMSTI4Port4PriorityLocalread-writecurrentEDD Series card MSTI Port Configuration: MSTI4 Normal Port4 Configuration - Priority
1.3.6.1.4.1.4756.20.440.20.1.589ColumneddMSTI5AggregatedPathCostLocalread-writecurrentEDD Series card MSTI Port Configuration: MSTI5 Aggregated Ports Configuration - Path Cost Valid values are in the range 0 to 200000000. Setting 0 means Auto pa…
1.3.6.1.4.1.4756.20.440.20.1.590ColumneddMSTI5AggregatedPriorityLocalread-writecurrentEDD Series card MSTI Port Configuration: MSTI5 Aggregated Ports Configuration - Priority
1.3.6.1.4.1.4756.20.440.20.1.591ColumneddMSTI5Port1PathCostLocalread-writecurrentEDD Series card MSTI Port Configuration: MSTI5 Normal Port1 Configuration - Path Cost Valid values are in the range 0 to 200000000. Setting 0 means Auto path c…
1.3.6.1.4.1.4756.20.440.20.1.592ColumneddMSTI5Port1PriorityLocalread-writecurrentEDD Series card MSTI Port Configuration: MSTI5 Normal Port1 Configuration - Priority
1.3.6.1.4.1.4756.20.440.20.1.593ColumneddMSTI5Port2PathCostLocalread-writecurrentEDD Series card MSTI Port Configuration: MSTI5 Normal Port2 Configuration - Path Cost Valid values are in the range 0 to 200000000. Setting 0 means Auto path c…
1.3.6.1.4.1.4756.20.440.20.1.594ColumneddMSTI5Port2PriorityLocalread-writecurrentEDD Series card MSTI Port Configuration: MSTI5 Normal Port2 Configuration - Priority
1.3.6.1.4.1.4756.20.440.20.1.595ColumneddMSTI5Port3PathCostLocalread-writecurrentEDD Series card MSTI Port Configuration: MSTI5 Normal Port3 Configuration - Path Cost Valid values are in the range 0 to 200000000. Setting 0 means Auto path c…
1.3.6.1.4.1.4756.20.440.20.1.596ColumneddMSTI5Port3PriorityLocalread-writecurrentEDD Series card MSTI Port Configuration: MSTI5 Normal Port3 Configuration - Priority
1.3.6.1.4.1.4756.20.440.20.1.597ColumneddMSTI5Port4PathCostLocalread-writecurrentEDD Series card MSTI Port Configuration: MSTI5 Normal Port4 Configuration - Path Cost Valid values are in the range 0 to 200000000. Setting 0 means Auto path c…
1.3.6.1.4.1.4756.20.440.20.1.598ColumneddMSTI5Port4PriorityLocalread-writecurrentEDD Series card MSTI Port Configuration: MSTI5 Normal Port4 Configuration - Priority
1.3.6.1.4.1.4756.20.440.20.1.599ColumneddMSTI6AggregatedPathCostLocalread-writecurrentEDD Series card MSTI Port Configuration: MSTI6 Aggregated Ports Configuration - Path Cost Valid values are in the range 0 to 200000000. Setting 0 means Auto pa…
1.3.6.1.4.1.4756.20.440.20.1.600ColumneddMSTI6AggregatedPriorityLocalread-writecurrentEDD Series card MSTI Port Configuration: MSTI6 Aggregated Ports Configuration - Priority
1.3.6.1.4.1.4756.20.440.20.1.601ColumneddMSTI6Port1PathCostLocalread-writecurrentEDD Series card MSTI Port Configuration: MSTI6 Normal Port1 Configuration - Path Cost Valid values are in the range 0 to 200000000. Setting 0 means Auto path c…
1.3.6.1.4.1.4756.20.440.20.1.602ColumneddMSTI6Port1PriorityLocalread-writecurrentEDD Series card MSTI Port Configuration: MSTI6 Normal Port1 Configuration - Priority
1.3.6.1.4.1.4756.20.440.20.1.603ColumneddMSTI6Port2PathCostLocalread-writecurrentEDD Series card MSTI Port Configuration: MSTI6 Normal Port2 Configuration - Path Cost Valid values are in the range 0 to 200000000. Setting 0 means Auto path c…
1.3.6.1.4.1.4756.20.440.20.1.604ColumneddMSTI6Port2PriorityLocalread-writecurrentEDD Series card MSTI Port Configuration: MSTI6 Normal Port2 Configuration - Priority
1.3.6.1.4.1.4756.20.440.20.1.605ColumneddMSTI6Port3PathCostLocalread-writecurrentEDD Series card MSTI Port Configuration: MSTI6 Normal Port3 Configuration - Path Cost Valid values are in the range 0 to 200000000. Setting 0 means Auto path c…
1.3.6.1.4.1.4756.20.440.20.1.606ColumneddMSTI6Port3PriorityLocalread-writecurrentEDD Series card MSTI Port Configuration: MSTI6 Normal Port3 Configuration - Priority
1.3.6.1.4.1.4756.20.440.20.1.607ColumneddMSTI6Port4PathCostLocalread-writecurrentEDD Series card MSTI Port Configuration: MSTI6 Normal Port4 Configuration - Path Cost Valid values are in the range 0 to 200000000. Setting 0 means Auto path c…
1.3.6.1.4.1.4756.20.440.20.1.608ColumneddMSTI6Port4PriorityLocalread-writecurrentEDD Series card MSTI Port Configuration: MSTI6 Normal Port4 Configuration - Priority
1.3.6.1.4.1.4756.20.440.20.1.609ColumneddMSTI7AggregatedPathCostLocalread-writecurrentEDD Series card MSTI Port Configuration: MSTI7 Aggregated Ports Configuration - Path Cost Valid values are in the range 0 to 200000000. Setting 0 means Auto pa…
1.3.6.1.4.1.4756.20.440.20.1.610ColumneddMSTI7AggregatedPriorityLocalread-writecurrentEDD Series card MSTI Port Configuration: MSTI7 Aggregated Ports Configuration - Priority
1.3.6.1.4.1.4756.20.440.20.1.611ColumneddMSTI7Port1PathCostLocalread-writecurrentEDD Series card MSTI Port Configuration: MSTI1 Normal Port1 Configuration - Path Cost Valid values are in the range 0 to 200000000. Setting 0 means Auto path c…
1.3.6.1.4.1.4756.20.440.20.1.612ColumneddMSTI7Port1PriorityLocalread-writecurrentEDD Series card MSTI Port Configuration: MSTI1 Normal Port7 Configuration - Priority
1.3.6.1.4.1.4756.20.440.20.1.613ColumneddMSTI7Port2PathCostLocalread-writecurrentEDD Series card MSTI Port Configuration: MSTI7 Normal Port2 Configuration - Path Cost Valid values are in the range 0 to 200000000. Setting 0 means Auto path c…
1.3.6.1.4.1.4756.20.440.20.1.614ColumneddMSTI7Port2PriorityLocalread-writecurrentEDD Series card MSTI Port Configuration: MSTI7 Normal Port2 Configuration - Priority
1.3.6.1.4.1.4756.20.440.20.1.615ColumneddMSTI7Port3PathCostLocalread-writecurrentEDD Series card MSTI Port Configuration: MSTI7 Normal Port3 Configuration - Path Cost Valid values are in the range 0 to 200000000. Setting 0 means Auto path c…
1.3.6.1.4.1.4756.20.440.20.1.616ColumneddMSTI7Port3PriorityLocalread-writecurrentEDD Series card MSTI Port Configuration: MSTI7 Normal Port3 Configuration - Priority
1.3.6.1.4.1.4756.20.440.20.1.617ColumneddMSTI7Port4PathCostLocalread-writecurrentEDD Series card MSTI Port Configuration: MSTI7 Normal Port4 Configuration - Path Cost Valid values are in the range 0 to 200000000. Setting 0 means Auto path c…
1.3.6.1.4.1.4756.20.440.20.1.618ColumneddMSTI7Port4PriorityLocalread-writecurrentEDD Series card MSTI Port Configuration: MSTI7 Normal Port4 Configuration - Priority
1.3.6.1.4.1.4756.20.440.20.1.619ColumneddCISTBridgeIDLocalread-onlycurrentEDD Series card STP Bridges status: CIST - Bridge ID
1.3.6.1.4.1.4756.20.440.20.1.620ColumneddCISTRootIDLocalread-onlycurrentEDD Series card STP Bridges status: CIST - Root ID
1.3.6.1.4.1.4756.20.440.20.1.621ColumneddCISTRootPortLocalread-onlycurrentEDD Series card STP Bridges status: CIST - Root Port
1.3.6.1.4.1.4756.20.440.20.1.622ColumneddCISTRootCostLocalread-onlycurrentEDD Series card STP Bridges status: CIST - Root Cost
1.3.6.1.4.1.4756.20.440.20.1.623ColumneddCISTTopologyFlagLocalread-onlycurrentEDD Series card STP Bridges status: CIST - Topology Flag
1.3.6.1.4.1.4756.20.440.20.1.624ColumneddCISTTopologyChangeLastLocalread-onlycurrentEDD Series card STP Bridges status: CIST - Topology Change Last
1.3.6.1.4.1.4756.20.440.20.1.625ColumneddMSTI1BridgeIDLocalread-onlycurrentEDD Series card STP Bridges status: MSTI1 - Bridge ID
1.3.6.1.4.1.4756.20.440.20.1.626ColumneddMSTI1RootIDLocalread-onlycurrentEDD Series card STP Bridges status: MSTI1 - Root ID
1.3.6.1.4.1.4756.20.440.20.1.627ColumneddMSTI1RootPortLocalread-onlycurrentEDD Series card STP Bridges status: MSTI1 - Root ID
1.3.6.1.4.1.4756.20.440.20.1.628ColumneddMSTI1RootCostLocalread-onlycurrentEDD Series card STP Bridges status: MSTI1 - Root Cost
1.3.6.1.4.1.4756.20.440.20.1.629ColumneddMSTI1TopologyFlagLocalread-onlycurrentEDD Series card STP Bridges status: MSTI1 - Topology Flag
1.3.6.1.4.1.4756.20.440.20.1.630ColumneddMSTI1TopologyChangeLastLocalread-onlycurrentEDD Series card STP Bridges status: MSTI1 - Topology Change Last
1.3.6.1.4.1.4756.20.440.20.1.631ColumneddMSTI2BridgeIDLocalread-onlycurrentEDD Series card STP Bridges status: MSTI2 - Bridge ID
1.3.6.1.4.1.4756.20.440.20.1.632ColumneddMSTI2RootIDLocalread-onlycurrentEDD Series card STP Bridges status: MSTI2 - Root ID
1.3.6.1.4.1.4756.20.440.20.1.633ColumneddMSTI2RootPortLocalread-onlycurrentEDD Series card STP Bridges status: MSTI2 - Root ID
1.3.6.1.4.1.4756.20.440.20.1.634ColumneddMSTI2RootCostLocalread-onlycurrentEDD Series card STP Bridges status: MSTI2 - Root Cost
1.3.6.1.4.1.4756.20.440.20.1.635ColumneddMSTI2TopologyFlagLocalread-onlycurrentEDD Series card STP Bridges status: MSTI2 - Topology Flag
1.3.6.1.4.1.4756.20.440.20.1.636ColumneddMSTI2TopologyChangeLastLocalread-onlycurrentEDD Series card STP Bridges status: MSTI2 - Topology Change Last
1.3.6.1.4.1.4756.20.440.20.1.637ColumneddMSTI3BridgeIDLocalread-onlycurrentEDD Series card STP Bridges status: MSTI3 - Bridge ID
1.3.6.1.4.1.4756.20.440.20.1.638ColumneddMSTI3RootIDLocalread-onlycurrentEDD Series card STP Bridges status: MSTI3 - Root ID
1.3.6.1.4.1.4756.20.440.20.1.639ColumneddMSTI3RootPortLocalread-onlycurrentEDD Series card STP Bridges status: MSTI3 - Root ID
1.3.6.1.4.1.4756.20.440.20.1.640ColumneddMSTI3RootCostLocalread-onlycurrentEDD Series card STP Bridges status: MSTI3 - Root Cost
1.3.6.1.4.1.4756.20.440.20.1.641ColumneddMSTI3TopologyFlagLocalread-onlycurrentEDD Series card STP Bridges status: MSTI3 - Topology Flag
1.3.6.1.4.1.4756.20.440.20.1.642ColumneddMSTI3TopologyChangeLastLocalread-onlycurrentEDD Series card STP Bridges status: MSTI3 - Topology Change Last
1.3.6.1.4.1.4756.20.440.20.1.643ColumneddMSTI4BridgeIDLocalread-onlycurrentEDD Series card STP Bridges status: MSTI4 - Bridge ID
1.3.6.1.4.1.4756.20.440.20.1.644ColumneddMSTI4RootIDLocalread-onlycurrentEDD Series card STP Bridges status: MSTI4 - Root ID
1.3.6.1.4.1.4756.20.440.20.1.645ColumneddMSTI4RootPortLocalread-onlycurrentEDD Series card STP Bridges status: MSTI4 - Root ID
1.3.6.1.4.1.4756.20.440.20.1.646ColumneddMSTI4RootCostLocalread-onlycurrentEDD Series card STP Bridges status: MSTI4 - Root Cost
1.3.6.1.4.1.4756.20.440.20.1.647ColumneddMSTI4TopologyFlagLocalread-onlycurrentEDD Series card STP Bridges status: MSTI4 - Topology Flag
1.3.6.1.4.1.4756.20.440.20.1.648ColumneddMSTI4TopologyChangeLastLocalread-onlycurrentEDD Series card STP Bridges status: MSTI4 - Topology Change Last
1.3.6.1.4.1.4756.20.440.20.1.649ColumneddMSTI5BridgeIDLocalread-onlycurrentEDD Series card STP Bridges status: MSTI5 - Bridge ID
1.3.6.1.4.1.4756.20.440.20.1.650ColumneddMSTI5RootIDLocalread-onlycurrentEDD Series card STP Bridges status: MSTI5 - Root ID
1.3.6.1.4.1.4756.20.440.20.1.651ColumneddMSTI5RootPortLocalread-onlycurrentEDD Series card STP Bridges status: MSTI5 - Root ID
1.3.6.1.4.1.4756.20.440.20.1.652ColumneddMSTI5RootCostLocalread-onlycurrentEDD Series card STP Bridges status: MSTI5 - Root Cost
1.3.6.1.4.1.4756.20.440.20.1.653ColumneddMSTI5TopologyFlagLocalread-onlycurrentEDD Series card STP Bridges status: MSTI5 - Topology Flag
1.3.6.1.4.1.4756.20.440.20.1.654ColumneddMSTI5TopologyChangeLastLocalread-onlycurrentEDD Series card STP Bridges status: MSTI5 - Topology Change Last
1.3.6.1.4.1.4756.20.440.20.1.655ColumneddMSTI6BridgeIDLocalread-onlycurrentEDD Series card STP Bridges status: MSTI6 - Bridge ID
1.3.6.1.4.1.4756.20.440.20.1.656ColumneddMSTI6RootIDLocalread-onlycurrentEDD Series card STP Bridges status: MSTI6 - Root ID
1.3.6.1.4.1.4756.20.440.20.1.657ColumneddMSTI6RootPortLocalread-onlycurrentEDD Series card STP Bridges status: MSTI6 - Root ID
1.3.6.1.4.1.4756.20.440.20.1.658ColumneddMSTI6RootCostLocalread-onlycurrentEDD Series card STP Bridges status: MSTI6 - Root Cost
1.3.6.1.4.1.4756.20.440.20.1.659ColumneddMSTI6TopologyFlagLocalread-onlycurrentEDD Series card STP Bridges status: MSTI6 - Topology Flag
1.3.6.1.4.1.4756.20.440.20.1.660ColumneddMSTI6TopologyChangeLastLocalread-onlycurrentEDD Series card STP Bridges status: MSTI6 - Topology Change Last
1.3.6.1.4.1.4756.20.440.20.1.661ColumneddMSTI7BridgeIDLocalread-onlycurrentEDD Series card STP Bridges status: MSTI7 - Bridge ID
1.3.6.1.4.1.4756.20.440.20.1.662ColumneddMSTI7RootIDLocalread-onlycurrentEDD Series card STP Bridges status: MSTI7 - Root ID
1.3.6.1.4.1.4756.20.440.20.1.663ColumneddMSTI7RootPortLocalread-onlycurrentEDD Series card STP Bridges status: MSTI7 - Root ID
1.3.6.1.4.1.4756.20.440.20.1.664ColumneddMSTI7RootCostLocalread-onlycurrentEDD Series card STP Bridges status: MSTI7 - Root Cost
1.3.6.1.4.1.4756.20.440.20.1.665ColumneddMSTI7TopologyFlagLocalread-onlycurrentEDD Series card STP Bridges status: MSTI7 - Topology Flag
1.3.6.1.4.1.4756.20.440.20.1.666ColumneddMSTI7TopologyChangeLastLocalread-onlycurrentEDD Series card STP Bridges status: MSTI7 - Topology Change Last
1.3.6.1.4.1.4756.20.440.20.1.667ColumneddSTPPortStatusInst1PortLocalread-onlycurrentEDD Series card STP Port status: Instance1 - Port
1.3.6.1.4.1.4756.20.440.20.1.668ColumneddSTPPortStatusInst1CISTRoleLocalread-onlycurrentEDD Series card STP Port status: Instance1 - CIST Role
1.3.6.1.4.1.4756.20.440.20.1.669ColumneddSTPPortStatusInst1CISTStateLocalread-onlycurrentEDD Series card STP Port status: Instance1 - CIST State
1.3.6.1.4.1.4756.20.440.20.1.670ColumneddSTPPortStatusInst1UptimeLocalread-onlycurrentEDD Series card STP Port status: Instance1 -Uptime
1.3.6.1.4.1.4756.20.440.20.1.671ColumneddSTPPortStatusInst2PortLocalread-onlycurrentEDD Series card STP Port status: Instance2 - Port
1.3.6.1.4.1.4756.20.440.20.1.672ColumneddSTPPortStatusInst2CISTRoleLocalread-onlycurrentEDD Series card STP Port status: Instance2 - CIST Role
1.3.6.1.4.1.4756.20.440.20.1.673ColumneddSTPPortStatusInst2CISTStateLocalread-onlycurrentEDD Series card STP Port status: Instance2 - CIST State
1.3.6.1.4.1.4756.20.440.20.1.674ColumneddSTPPortStatusInst2UptimeLocalread-onlycurrentEDD Series card STP Port status: Instance2 -Uptime
1.3.6.1.4.1.4756.20.440.20.1.675ColumneddSTPPortStatusInst3PortLocalread-onlycurrentEDD Series card STP Port status: Instance3 - Port
1.3.6.1.4.1.4756.20.440.20.1.676ColumneddSTPPortStatusInst3CISTRoleLocalread-onlycurrentEDD Series card STP Port status: Instance3 - CIST Role
1.3.6.1.4.1.4756.20.440.20.1.677ColumneddSTPPortStatusInst3CISTStateLocalread-onlycurrentEDD Series card STP Port status: Instance3 - CIST State
1.3.6.1.4.1.4756.20.440.20.1.678ColumneddSTPPortStatusInst3UptimeLocalread-onlycurrentEDD Series card STP Port status: Instance3 -Uptime
1.3.6.1.4.1.4756.20.440.20.1.679ColumneddSTPPortStatusInst4PortLocalread-onlycurrentEDD Series card STP Port status: Instance4 - Port
1.3.6.1.4.1.4756.20.440.20.1.680ColumneddSTPPortStatusInst4CISTRoleLocalread-onlycurrentEDD Series card STP Port status: Instance4 - CIST Role
1.3.6.1.4.1.4756.20.440.20.1.681ColumneddSTPPortStatusInst4CISTStateLocalread-onlycurrentEDD Series card STP Port status: Instance4 - CIST State
1.3.6.1.4.1.4756.20.440.20.1.682ColumneddSTPPortStatusInst4UptimeLocalread-onlycurrentEDD Series card STP Port status: Instance4 -Uptime
1.3.6.1.4.1.4756.20.440.20.1.683ColumneddSTPStatisticsPort1TxMSTPLocalread-onlycurrentEDD Series card STP Port Statistics: Port1 -Transmitted MSTP
1.3.6.1.4.1.4756.20.440.20.1.684ColumneddSTPStatisticsPort1TxRSTPLocalread-onlycurrentEDD Series card STP Port Statistics: Port1 -Transmitted RSTP
1.3.6.1.4.1.4756.20.440.20.1.685ColumneddSTPStatisticsPort1TxSTPLocalread-onlycurrentEDD Series card STP Port Statistics: Port1 -Transmitted RSTP
1.3.6.1.4.1.4756.20.440.20.1.686ColumneddSTPStatisticsPort1TxTCNLocalread-onlycurrentEDD Series card STP Port Statistics: Port1 -Transmitted RSTP
1.3.6.1.4.1.4756.20.440.20.1.687ColumneddSTPStatisticsPort1RxMSTPLocalread-onlycurrentEDD Series card STP Port Statistics: Port1 -Received MSTP
1.3.6.1.4.1.4756.20.440.20.1.688ColumneddSTPStatisticsPort1RxRSTPLocalread-onlycurrentEDD Series card STP Port Statistics: Port1 -Received RSTP
1.3.6.1.4.1.4756.20.440.20.1.689ColumneddSTPStatisticsPort1RxSTPLocalread-onlycurrentEDD Series card STP Port Statistics: Port1 -Received RSTP
1.3.6.1.4.1.4756.20.440.20.1.690ColumneddSTPStatisticsPort1RxTCNLocalread-onlycurrentEDD Series card STP Port Statistics: Port1 -Received RSTP
1.3.6.1.4.1.4756.20.440.20.1.691ColumneddSTPStatisticsPort1DiscardUnknowLocalread-onlycurrentEDD Series card STP Port Statistics: Port1 -Discarded Unknown
1.3.6.1.4.1.4756.20.440.20.1.692ColumneddSTPStatisticsPort1DiscardIllegalLocalread-onlycurrentEDD Series card STP Port Statistics: Port1 -Discarded Illegal
1.3.6.1.4.1.4756.20.440.20.1.693ColumneddSTPStatisticsPort2TxMSTPLocalread-onlycurrentEDD Series card STP Port Statistics: Port2 -Transmitted MSTP
1.3.6.1.4.1.4756.20.440.20.1.694ColumneddSTPStatisticsPort2TxRSTPLocalread-onlycurrentEDD Series card STP Port Statistics: Port2 -Transmitted RSTP
1.3.6.1.4.1.4756.20.440.20.1.695ColumneddSTPStatisticsPort2TxSTPLocalread-onlycurrentEDD Series card STP Port Statistics: Port2 -Transmitted RSTP
1.3.6.1.4.1.4756.20.440.20.1.696ColumneddSTPStatisticsPort2TxTCNLocalread-onlycurrentEDD Series card STP Port Statistics: Port2 -Transmitted RSTP
1.3.6.1.4.1.4756.20.440.20.1.697ColumneddSTPStatisticsPort2RxMSTPLocalread-onlycurrentEDD Series card STP Port Statistics: Port2 -Received MSTP
1.3.6.1.4.1.4756.20.440.20.1.698ColumneddSTPStatisticsPort2RxRSTPLocalread-onlycurrentEDD Series card STP Port Statistics: Port1 -Received RSTP
1.3.6.1.4.1.4756.20.440.20.1.699ColumneddSTPStatisticsPort2RxSTPLocalread-onlycurrentEDD Series card STP Port Statistics: Port2 -Received RSTP
1.3.6.1.4.1.4756.20.440.20.1.700ColumneddSTPStatisticsPort2RxTCNLocalread-onlycurrentEDD Series card STP Port Statistics: Port2 -Received RSTP
1.3.6.1.4.1.4756.20.440.20.1.701ColumneddSTPStatisticsPort2DiscardUnknowLocalread-onlycurrentEDD Series card STP Port Statistics: Port2 -Discarded Unknown
1.3.6.1.4.1.4756.20.440.20.1.702ColumneddSTPStatisticsPort2DiscardIllegalLocalread-onlycurrentEDD Series card STP Port Statistics: Port2 -Discarded Illegal
1.3.6.1.4.1.4756.20.440.20.1.703ColumneddSTPStatisticsPort3TxMSTPLocalread-onlycurrentEDD Series card STP Port Statistics: Port3 -Transmitted MSTP
1.3.6.1.4.1.4756.20.440.20.1.704ColumneddSTPStatisticsPort3TxRSTPLocalread-onlycurrentEDD Series card STP Port Statistics: Port3 -Transmitted RSTP
1.3.6.1.4.1.4756.20.440.20.1.705ColumneddSTPStatisticsPort3TxSTPLocalread-onlycurrentEDD Series card STP Port Statistics: Port3 -Transmitted RSTP
1.3.6.1.4.1.4756.20.440.20.1.706ColumneddSTPStatisticsPort3TxTCNLocalread-onlycurrentEDD Series card STP Port Statistics: Port3 -Transmitted RSTP
1.3.6.1.4.1.4756.20.440.20.1.707ColumneddSTPStatisticsPort3RxMSTPLocalread-onlycurrentEDD Series card STP Port Statistics: Port3 -Received MSTP
1.3.6.1.4.1.4756.20.440.20.1.708ColumneddSTPStatisticsPort3RxRSTPLocalread-onlycurrentEDD Series card STP Port Statistics: Port3 -Received RSTP
1.3.6.1.4.1.4756.20.440.20.1.709ColumneddSTPStatisticsPort3RxSTPLocalread-onlycurrentEDD Series card STP Port Statistics: Port3 -Received RSTP
1.3.6.1.4.1.4756.20.440.20.1.710ColumneddSTPStatisticsPort3RxTCNLocalread-onlycurrentEDD Series card STP Port Statistics: Port3 -Received RSTP
1.3.6.1.4.1.4756.20.440.20.1.711ColumneddSTPStatisticsPort3DiscardUnknowLocalread-onlycurrentEDD Series card STP Port Statistics: Port3 -Discarded Unknown
1.3.6.1.4.1.4756.20.440.20.1.712ColumneddSTPStatisticsPort3DiscardIllegalLocalread-onlycurrentEDD Series card STP Port Statistics: Port3 -Discarded Illegal
1.3.6.1.4.1.4756.20.440.20.1.713ColumneddSTPStatisticsPort4TxMSTPLocalread-onlycurrentEDD Series card STP Port Statistics: Port4 -Transmitted MSTP
1.3.6.1.4.1.4756.20.440.20.1.714ColumneddSTPStatisticsPort4TxRSTPLocalread-onlycurrentEDD Series card STP Port Statistics: Port4 -Transmitted RSTP
1.3.6.1.4.1.4756.20.440.20.1.715ColumneddSTPStatisticsPort4TxSTPLocalread-onlycurrentEDD Series card STP Port Statistics: Port4 -Transmitted RSTP
1.3.6.1.4.1.4756.20.440.20.1.716ColumneddSTPStatisticsPort4TxTCNLocalread-onlycurrentEDD Series card STP Port Statistics: Port4 -Transmitted RSTP
1.3.6.1.4.1.4756.20.440.20.1.717ColumneddSTPStatisticsPort4RxMSTPLocalread-onlycurrentEDD Series card STP Port Statistics: Port4 -Received MSTP
1.3.6.1.4.1.4756.20.440.20.1.718ColumneddSTPStatisticsPort4RxRSTPLocalread-onlycurrentEDD Series card STP Port Statistics: Port4 -Received RSTP
1.3.6.1.4.1.4756.20.440.20.1.719ColumneddSTPStatisticsPort4RxSTPLocalread-onlycurrentEDD Series card STP Port Statistics: Port4 -Received RSTP
1.3.6.1.4.1.4756.20.440.20.1.720ColumneddSTPStatisticsPort4RxTCNLocalread-onlycurrentEDD Series card STP Port Statistics: Port4 -Received RSTP
1.3.6.1.4.1.4756.20.440.20.1.721ColumneddSTPStatisticsPort4DiscardUnknowLocalread-onlycurrentEDD Series card STP Port Statistics: Port4 -Discarded Unknown
1.3.6.1.4.1.4756.20.440.20.1.722ColumneddSTPStatisticsPort4DiscardIllegalLocalread-onlycurrentEDD Series card STP Port Statistics: Port4 -Discarded Illegal
1.3.6.1.4.1.4756.20.440.20.1.723ColumneddSTPStatisticsPortClearCounterLocalread-writecurrentEDD Series card STP Port Statistics: Clear Counters 0: OFff 1: Action
1.3.6.1.4.1.4756.20.440.20.1.724ColumneddAllowedAccessVLANsLocalread-writecurrentEDD Series card Global VLAN Configuration: Allowed Access VLANs By default, only VLAN 1 is enabled. More VLANs may be created by using a list syntax where the …
1.3.6.1.4.1.4756.20.440.20.1.725ColumneddVlanEthertypeLocalread-writecurrentEDD Series card Global VLAN Configuration: Ethertype for Custom S-ports The format of 'Ethernet Type' is restricted to 0x600-0xFFFF
1.3.6.1.4.1.4756.20.440.20.1.726ColumneddPort1VlanModeLocalread-writecurrentEDD Series card Port VLAN Configuration : Port1 - Mode 0: Access 1: Trunk 2: Hybrid
1.3.6.1.4.1.4756.20.440.20.1.727ColumneddPort1VlanIDLocalread-writecurrentEDD Series card Port VLAN Configuration : Port1 - VLAN ID
1.3.6.1.4.1.4756.20.440.20.1.728ColumneddPort1VlanTypeLocalread-writecurrentEDD Series card Port VLAN Configuration : Port1 - VLAN Type 0: Unaware 1: C-port 2: S-port 3: S-custom-port
1.3.6.1.4.1.4756.20.440.20.1.729ColumneddPort1VlanIngressFilteringLocalread-writecurrentEDD Series card Port VLAN Configuration : Port1 - Ingress Filtering 0: Off 1: On
1.3.6.1.4.1.4756.20.440.20.1.730ColumneddPort1VlanIngressAcceptanceLocalread-writecurrentEDD Series card Port VLAN Configuration : Port1 - Ingress Acceptance 0: Tagged and untagged 1: Tagged only 2: Untagged only
1.3.6.1.4.1.4756.20.440.20.1.731ColumneddPort1VlanEgressTaggingLocalread-writecurrentEDD Series card Port VLAN Configuration : Port1 - Egress Tagging 0: Untag port vlan 1: Tag all 2: Untag all
1.3.6.1.4.1.4756.20.440.20.1.732ColumneddPort1AllowedVLANSLocalread-writecurrentEDD Series card Global VLAN Configuration: Port1 - Allowed VLANs By default, only VLAN 1 is enabled. More VLANs may be created by using a list syntax where the…
1.3.6.1.4.1.4756.20.440.20.1.733ColumneddPort1ForbiddenVLANSLocalread-writecurrentEDD Series card Global VLAN Configuration: Port1 - Forbidden VLANs By default, the field is left blank, which means that the port may become a member of all po…
1.3.6.1.4.1.4756.20.440.20.1.734ColumneddPort2VlanModeLocalread-writecurrentEDD Series card Port VLAN Configuration : Port2 - Mode 0: Access 1: Trunk 2: Hybrid
1.3.6.1.4.1.4756.20.440.20.1.735ColumneddPort2VlanIDLocalread-writecurrentEDD Series card Port VLAN Configuration : Port2 - VLAN ID
1.3.6.1.4.1.4756.20.440.20.1.736ColumneddPort2VlanTypeLocalread-writecurrentEDD Series card Port VLAN Configuration : Port2 - VLAN Type 0: Unaware 1: C-port 2: S-port 3: S-custom-port
1.3.6.1.4.1.4756.20.440.20.1.737ColumneddPort2VlanIngressFilteringLocalread-writecurrentEDD Series card Port VLAN Configuration : Port2 - Ingress Filtering 0: Off 1: On
1.3.6.1.4.1.4756.20.440.20.1.738ColumneddPort2VlanIngressAcceptanceLocalread-writecurrentEDD Series card Port VLAN Configuration : Por2 - Ingress Acceptance 0: Tagged and untagged 1: Tagged only 2: Untagged only
1.3.6.1.4.1.4756.20.440.20.1.739ColumneddPort2VlanEgressTaggingLocalread-writecurrentEDD Series card Port VLAN Configuration : Port2 - Egress Tagging 0: Untag port vlan 1: Tag all 2: Untag all
1.3.6.1.4.1.4756.20.440.20.1.740ColumneddPort2AllowedVLANSLocalread-writecurrentEDD Series card Global VLAN Configuration: Port2 - Allowed VLANs By default, only VLAN 1 is enabled. More VLANs may be created by using a list syntax where the…
1.3.6.1.4.1.4756.20.440.20.1.741ColumneddPort2ForbiddenVLANSLocalread-writecurrentEDD Series card Global VLAN Configuration: Port2 - Forbidden VLANs By default, the field is left blank, which means that the port may become a member of all po…
1.3.6.1.4.1.4756.20.440.20.1.742ColumneddPort3VlanModeLocalread-writecurrentEDD Series card Port VLAN Configuration : Port3 - Mode 0: Access 1: Trunk 2: Hybrid
1.3.6.1.4.1.4756.20.440.20.1.743ColumneddPort3VlanIDLocalread-writecurrentEDD Series card Port VLAN Configuration : Port3 - VLAN ID
1.3.6.1.4.1.4756.20.440.20.1.744ColumneddPort3VlanTypeLocalread-writecurrentEDD Series card Port VLAN Configuration : Port3 - VLAN Type 0: Unaware 1: C-port 2: S-port 3: S-custom-port
1.3.6.1.4.1.4756.20.440.20.1.745ColumneddPort3VlanIngressFilteringLocalread-writecurrentEDD Series card Port VLAN Configuration : Port3 - Ingress Filtering 0: Off 1: On
1.3.6.1.4.1.4756.20.440.20.1.746ColumneddPort3VlanIngressAcceptanceLocalread-writecurrentEDD Series card Port VLAN Configuration : Port3 - Ingress Acceptance 0: Tagged and untagged 1: Tagged only 2: Untagged only
1.3.6.1.4.1.4756.20.440.20.1.747ColumneddPort3VlanEgressTaggingLocalread-writecurrentEDD Series card Port VLAN Configuration : Port3 - Egress Tagging 0: Untag port vlan 1: Tag all 2: Untag all
1.3.6.1.4.1.4756.20.440.20.1.748ColumneddPort3AllowedVLANSLocalread-writecurrentEDD Series card Global VLAN Configuration: Port3 - Allowed VLANs By default, only VLAN 1 is enabled. More VLANs may be created by using a list syntax where the…
1.3.6.1.4.1.4756.20.440.20.1.749ColumneddPort3ForbiddenVLANSLocalread-writecurrentEDD Series card Global VLAN Configuration: Port3 - Forbidden VLANs By default, the field is left blank, which means that the port may become a member of all po…
1.3.6.1.4.1.4756.20.440.20.1.750ColumneddPort4VlanModeLocalread-writecurrentEDD Series card Port VLAN Configuration : Port4 - Mode 0: Access 1: Trunk 2: Hybrid
1.3.6.1.4.1.4756.20.440.20.1.751ColumneddPort4VlanIDLocalread-writecurrentEDD Series card Port VLAN Configuration : Port4 - VLAN ID
1.3.6.1.4.1.4756.20.440.20.1.752ColumneddPort4VlanTypeLocalread-writecurrentEDD Series card Port VLAN Configuration : Port4 - VLAN Type 0: Unaware 1: C-port 2: S-port 3: S-custom-port
1.3.6.1.4.1.4756.20.440.20.1.753ColumneddPort4VlanIngressFilteringLocalread-writecurrentEDD Series card Port VLAN Configuration : Port4 - Ingress Filtering 0: Off 1: On
1.3.6.1.4.1.4756.20.440.20.1.754ColumneddPort4VlanIngressAcceptanceLocalread-writecurrentEDD Series card Port VLAN Configuration : Port4 - Ingress Acceptance 0: Tagged and untagged 1: Tagged only 2: Untagged only
1.3.6.1.4.1.4756.20.440.20.1.755ColumneddPort4VlanEgressTaggingLocalread-writecurrentEDD Series card Port VLAN Configuration : Port4 - Egress Tagging 0: Untag port vlan 1: Tag all 2: Untag all
1.3.6.1.4.1.4756.20.440.20.1.756ColumneddPort4AllowedVLANSLocalread-writecurrentEDD Series card Global VLAN Configuration: Port4 - Allowed VLANs By default, only VLAN 1 is enabled. More VLANs may be created by using a list syntax where the…
1.3.6.1.4.1.4756.20.440.20.1.757ColumneddPort4ForbiddenVLANSLocalread-writecurrentEDD Series card Global VLAN Configuration: Port4 - Forbidden VLANs By default, the field is left blank, which means that the port may become a member of all po…
1.3.6.1.4.1.4756.20.440.20.1.758ColumneddDNSServerTypeLocalread-writecurrentEDD Series card IP Configuration: This setting controls the DNS name resolution done by the switch. The following modes are supported: 1:From any DHCP interfac…
1.3.6.1.4.1.4756.20.440.20.1.759ColumneddDNSServerSettingLocalread-writecurrentEDD Series card IP Configuration: If iDNSServerType setting '3:Configured',this value must setting IP address format as below: Dotted Decimal Notation refers t…
1.3.6.1.4.1.4756.20.440.20.1.760ColumneddDNSproxyLocalread-writecurrentEDD Series card IP Configuration: When DNS proxy is enabled, system will relay DNS requests to the currently configured DNS server, and reply as a DNS resolver…
1.3.6.1.4.1.4756.20.440.20.1.761ColumneddAddIPV4InterfaceLocalread-writecurrentEDD Series card IP Interfaces: Add a new IP VLAN Interface: Syntax: [<Interface>] [<vlan_list>] [<IPV4_Addr>] [<IPV4_MASK>] Interface : 1~4
1.3.6.1.4.1.4756.20.440.20.1.762ColumneddDeleteInterfaceLocalread-writecurrentEDD Series card IP Interfaces: Delete a IPv4/v6 VLAN Interface: Syntax: [<Interface>] Interface: 1~4
1.3.6.1.4.1.4756.20.440.20.1.763ColumneddIPInterface1VLANLocalread-onlycurrentEDD Series card IP Interfaces: The VLAN associated with the IP interface. Only ports in this VLAN will be able to access the IP interface. This field is only a…
1.3.6.1.4.1.4756.20.440.20.1.764ColumneddIPInterface1DHCPLocalread-writecurrentEDD Series card IP Interfaces: DHCP
1.3.6.1.4.1.4756.20.440.20.1.765ColumneddIPInterface1FallbackLocalread-writecurrentEDD Series card IP Interfaces: Fallback
1.3.6.1.4.1.4756.20.440.20.1.766ColumneddIPInterface1IPV4AddressLocalread-onlycurrentEDD Series card IP Interfaces: IPV4 Address
1.3.6.1.4.1.4756.20.440.20.1.767ColumneddIPInterface1IPV4MASKLenLocalread-onlycurrentEDD Series card IP Interfaces: IPV4 MASK Length
1.3.6.1.4.1.4756.20.440.20.1.768ColumneddIPInterface2VLANLocalread-onlycurrentEDD Series card IP Interfaces: The VLAN associated with the IP interface. Only ports in this VLAN will be able to access the IP interface. This field is only a…
1.3.6.1.4.1.4756.20.440.20.1.769ColumneddIPInterface2DHCPLocalread-writecurrentEDD Series card IP Interfaces: DHCP
1.3.6.1.4.1.4756.20.440.20.1.770ColumneddIPInterface2FallbackLocalread-writecurrentEDD Series card IP Interfaces: Fallback
1.3.6.1.4.1.4756.20.440.20.1.771ColumneddIPInterface2IPV4AddressLocalread-onlycurrentEDD Series card IP Interfaces: IPV4 Address
1.3.6.1.4.1.4756.20.440.20.1.772ColumneddIPInterface2IPV4MASKLenLocalread-onlycurrentEDD Series card IP Interfaces: IPV4 MASK Length
1.3.6.1.4.1.4756.20.440.20.1.773ColumneddIPInterface3VLANLocalread-onlycurrentEDD Series card IP Interfaces: The VLAN associated with the IP interface. Only ports in this VLAN will be able to access the IP interface. This field is only a…
1.3.6.1.4.1.4756.20.440.20.1.774ColumneddIPInterface3DHCPLocalread-writecurrentEDD Series card IP Interfaces: DHCP
1.3.6.1.4.1.4756.20.440.20.1.775ColumneddIPInterface3FallbackLocalread-writecurrentEDD Series card IP Interfaces: Fallback
1.3.6.1.4.1.4756.20.440.20.1.776ColumneddIPInterface3IPV4AddressLocalread-onlycurrentEDD Series card IP Interfaces: IPV4 Address
1.3.6.1.4.1.4756.20.440.20.1.777ColumneddIPInterface3IPV4MASKLenLocalread-onlycurrentEDD Series card IP Interfaces: IPV4 MASK Length
1.3.6.1.4.1.4756.20.440.20.1.778ColumneddIPInterface4VLANLocalread-onlycurrentEDD Series card IP Interfaces: The VLAN associated with the IP interface. Only ports in this VLAN will be able to access the IP interface. This field is only a…
1.3.6.1.4.1.4756.20.440.20.1.779ColumneddIPInterface4DHCPLocalread-writecurrentEDD Series card IP Interfaces: DHCP
1.3.6.1.4.1.4756.20.440.20.1.780ColumneddIPInterface4FallbackLocalread-writecurrentEDD Series card IP Interfaces: Fallback
1.3.6.1.4.1.4756.20.440.20.1.781ColumneddIPInterface4IPV4AddressLocalread-onlycurrentEDD Series card IP Interfaces: IPV4 Address
1.3.6.1.4.1.4756.20.440.20.1.782ColumneddIPInterface4IPV4MASKLenLocalread-onlycurrentEDD Series card IP Interfaces: IPV4 MASK Length
1.3.6.1.4.1.4756.20.440.20.1.783ColumneddAddIPV6InterfaceLocalread-writecurrentEDD Series card IP Interfaces: Add a new IPv6 VLAN Interface: Syntax: [<Interface>] [<vlan_list>] [<IPV4_Addr>] [<IPV4_MASK>] Interface : 1~4
1.3.6.1.4.1.4756.20.440.20.1.784ColumneddIPInterface1IPV6AddressLocalread-onlycurrentEDD Series card IP Interfaces: IPV6 Address
1.3.6.1.4.1.4756.20.440.20.1.785ColumneddIPInterface1IPV6MASKLenLocalread-onlycurrentEDD Series card IP Interfaces: IPV6 MASK Length
1.3.6.1.4.1.4756.20.440.20.1.786ColumneddIPInterface2IPV6AddressLocalread-onlycurrentEDD Series card IP Interfaces: IPV6 Address
1.3.6.1.4.1.4756.20.440.20.1.787ColumneddIPInterface2IPV6MASKLenLocalread-onlycurrentEDD Series card IP Interfaces: IPV6 MASK Length
1.3.6.1.4.1.4756.20.440.20.1.788ColumneddIPInterface3IPV6AddressLocalread-onlycurrentEDD Series card IP Interfaces: IPV6 Address
1.3.6.1.4.1.4756.20.440.20.1.789ColumneddIPInterface3IPV6MASKLenLocalread-onlycurrentEDD Series card IP Interfaces: IPV6 MASK Length
1.3.6.1.4.1.4756.20.440.20.1.790ColumneddIPInterface4IPV6AddressLocalread-onlycurrentEDD Series card IP Interfaces: IPV6 Address
1.3.6.1.4.1.4756.20.440.20.1.791ColumneddIPInterface4IPV6MASKLenLocalread-onlycurrentEDD Series card IP Interfaces: IPV6 MASK Length
1.3.6.1.4.1.4756.20.440.20.1.792ColumneddPort1ALSLocalread-writecurrentEDD Series card Port1 auto laser shutdown: 0: Disable 1: Enable
1.3.6.1.4.1.4756.20.440.20.1.793ColumneddPort2ALSLocalread-writecurrentEDD Series card Port2 auto laser shutdown: 0: Disable 1: Enable
1.3.6.1.4.1.4756.20.440.20.1.794ColumneddPort3ALSLocalread-writecurrentEDD Series card Port3 auto laser shutdown (MX210 only): 0: Disable 1: Enable
1.3.6.1.4.1.4756.20.440.20.1.795ColumneddPort1LLFLogicLocalread-writecurrentEDD Series card Port1 link loss forwarding - Logic 0: AND 1: OR
1.3.6.1.4.1.4756.20.440.20.1.796ColumneddPort1LLFLogicPort2Localread-writecurrentEDD Series card Port1 link loss forwarding - Link/Rx Loss Port2 0: NO 1: YES
1.3.6.1.4.1.4756.20.440.20.1.797ColumneddPort1LLFLogicPort3Localread-writecurrentEDD Series card Port1 link loss forwarding - Link/Rx Loss Port3 0: NO 1: YES
1.3.6.1.4.1.4756.20.440.20.1.798ColumneddPort1LLFLogicPort4Localread-writecurrentEDD Series card Port1 link loss forwarding - Link/Rx Loss Port4 0: NO 1: YES
1.3.6.1.4.1.4756.20.440.20.1.799ColumneddPort2LLFLogicLocalread-writecurrentEDD Series card Port2 link loss forwarding - Logic 0: AND 1: OR
1.3.6.1.4.1.4756.20.440.20.1.800ColumneddPort2LLFLogicPort1Localread-writecurrentEDD Series card Port2 link loss forwarding - Link/Rx Loss Port1 0: NO 1: YES
1.3.6.1.4.1.4756.20.440.20.1.801ColumneddPort2LLFLogicPort3Localread-writecurrentEDD Series card Port2 link loss forwarding - Link/Rx Loss Port3 0: NO 1: YES
1.3.6.1.4.1.4756.20.440.20.1.802ColumneddPort2LLFLogicPort4Localread-writecurrentEDD Series card Port2 link loss forwarding - Link/Rx Loss Port4 0: NO 1: YES
1.3.6.1.4.1.4756.20.440.20.1.803ColumneddPort3LLFLogicLocalread-writecurrentEDD Series card Port1 link loss forwarding - Logic 0: AND 1: OR
1.3.6.1.4.1.4756.20.440.20.1.804ColumneddPort3LLFLogicPort1Localread-writecurrentEDD Series card Port3 link loss forwarding - Link/Rx Loss Port1 0: NO 1: YES
1.3.6.1.4.1.4756.20.440.20.1.805ColumneddPort3LLFLogicPort2Localread-writecurrentEDD Series card Port3 link loss forwarding - Link/Rx Loss Port2 0: NO 1: YES
1.3.6.1.4.1.4756.20.440.20.1.806ColumneddPort3LLFLogicPort4Localread-writecurrentEDD Series card Port3 link loss forwarding - Link/Rx Loss Port4 0: NO 1: YES
1.3.6.1.4.1.4756.20.440.20.1.807ColumneddPort4LLFLogicLocalread-writecurrentEDD Series card Port4 link loss forwarding - Logic 0: AND 1: OR
1.3.6.1.4.1.4756.20.440.20.1.808ColumneddPort4LLFLogicPort1Localread-writecurrentEDD Series card Port4 link loss forwarding - Link/Rx Loss Port1 0: NO 1: YES
1.3.6.1.4.1.4756.20.440.20.1.809ColumneddPort4LLFLogicPort2Localread-writecurrentEDD Series card Port4 link loss forwarding - Link/Rx Loss Port2 0: NO 1: YES
1.3.6.1.4.1.4756.20.440.20.1.810ColumneddPort4LLFLogicPort3Localread-writecurrentEDD Series card Port4 link loss forwarding - Link/Rx Loss Port3 0: NO 1: YES
1.3.6.1.4.1.4756.20.440.20.1.811ColumneddQOSPort1IngressLocalread-writecurrentEDD Series card QOS Port1 Ingress Enabled 0: NO 1: YES
1.3.6.1.4.1.4756.20.440.20.1.812ColumneddQOSPort1IngressRateLocalread-writecurrentEDD Series card QOS Port1 Ingress Rate
1.3.6.1.4.1.4756.20.440.20.1.813ColumneddQOSPort1IngressRateUnitLocalread-writecurrentEDD Series card QOS Port1 Ingress Rate Unit 0: Kbps 1: Mbps 2: fps 3: kfps
1.3.6.1.4.1.4756.20.440.20.1.814ColumneddQOSPort1IngressFlowControlLocalread-writecurrentEDD Series card QOS Port1 Ingress Flow Control 0: NO 1: YES
1.3.6.1.4.1.4756.20.440.20.1.815ColumneddQOSPort2IngressLocalread-writecurrentEDD Series card QOS Port2 Ingress Enabled 0: NO 1: YES
1.3.6.1.4.1.4756.20.440.20.1.816ColumneddQOSPort2IngressRateLocalread-writecurrentEDD Series card QOS Port2 Ingress Rate
1.3.6.1.4.1.4756.20.440.20.1.817ColumneddQOSPort2IngressRateUnitLocalread-writecurrentEDD Series card QOS Port2 Ingress Rate Unit 0: Kbps 1: Mbps 2: fps 3: kfps
1.3.6.1.4.1.4756.20.440.20.1.818ColumneddQOSPort2IngressFlowControlLocalread-writecurrentEDD Series card QOS Port2 Ingress Flow Control 0: NO 1: YES
1.3.6.1.4.1.4756.20.440.20.1.819ColumneddQOSPort3IngressLocalread-writecurrentEDD Series card QOS Port3 Ingress Enabled 0: NO 1: YES
1.3.6.1.4.1.4756.20.440.20.1.820ColumneddQOSPort3IngressRateLocalread-writecurrentEDD Series card QOS Port3 Ingress Rate
1.3.6.1.4.1.4756.20.440.20.1.821ColumneddQOSPort3IngressRateUnitLocalread-writecurrentEDD Series card QOS Port3 Ingress Rate Unit 0: Kbps 1: Mbps 2: fps 3: kfps
1.3.6.1.4.1.4756.20.440.20.1.822ColumneddQOSPort3IngressFlowControlLocalread-writecurrentEDD Series card QOS Port3 Ingress Flow Control 0: NO 1: YES
1.3.6.1.4.1.4756.20.440.20.1.823ColumneddQOSPort4IngressLocalread-writecurrentEDD Series card QOS Port4 Ingress Enabled 0: NO 1: YES
1.3.6.1.4.1.4756.20.440.20.1.824ColumneddQOSPort4IngressRateLocalread-writecurrentEDD Series card QOS Port4 Ingress Rate
1.3.6.1.4.1.4756.20.440.20.1.825ColumneddQOSPort4IngressRateUnitLocalread-writecurrentEDD Series card QOS Port4 Ingress Rate Unit 0: Kbps 1: Mbps 2: fps 3: kfps
1.3.6.1.4.1.4756.20.440.20.1.826ColumneddQOSPort4IngressFlowControlLocalread-writecurrentEDD Series card QOS Port4 Ingress Flow Control 0: NO 1: YES
1.3.6.1.4.1.4756.20.440.20.1.827ColumneddQOSPort1EgressLocalread-writecurrentEDD Series card QOS Port1 Egress Enabled 0: NO 1: YES
1.3.6.1.4.1.4756.20.440.20.1.828ColumneddQOSPort1EgressRateLocalread-writecurrentEDD Series card QOS Port1 Egress Rate
1.3.6.1.4.1.4756.20.440.20.1.829ColumneddQOSPort1EgressRateUnitLocalread-writecurrentEDD Series card QOS Port1 Egress Rate Unit 0: Kbps 1: Mbps
1.3.6.1.4.1.4756.20.440.20.1.830ColumneddQOSPort2EgressLocalread-writecurrentEDD Series card QOS Port2 Egress Enabled 0: NO 1: YES
1.3.6.1.4.1.4756.20.440.20.1.831ColumneddQOSPort2EgressRateLocalread-writecurrentEDD Series card QOS Port2 Egress Rate
1.3.6.1.4.1.4756.20.440.20.1.832ColumneddQOSPort2EgressRateUnitLocalread-writecurrentEDD Series card QOS Port2 Egress Rate Unit 0: Kbps 1: Mbps
1.3.6.1.4.1.4756.20.440.20.1.833ColumneddQOSPort3EgressLocalread-writecurrentEDD Series card QOS Port3 Egress Enabled 0: NO 1: YES
1.3.6.1.4.1.4756.20.440.20.1.834ColumneddQOSPort3EgressRateLocalread-writecurrentEDD Series card QOS Port3 Egress Rate
1.3.6.1.4.1.4756.20.440.20.1.835ColumneddQOSPort3EgressRateUnitLocalread-writecurrentEDD Series card QOS Port3 Egress Rate Unit 0: Kbps 1: Mbps
1.3.6.1.4.1.4756.20.440.20.1.836ColumneddQOSPort4EgressLocalread-writecurrentEDD Series card QOS Port4 Egress Enabled 0: NO 1: YES
1.3.6.1.4.1.4756.20.440.20.1.837ColumneddQOSPort4EgressRateLocalread-writecurrentEDD Series card QOS Port4 Egress Rate
1.3.6.1.4.1.4756.20.440.20.1.838ColumneddQOSPort4EgressRateUnitLocalread-writecurrentEDD Series card QOS Port4 Egress Rate Unit 0: Kbps 1: Mbps
1.3.6.1.4.1.4756.20.440.20.1.839ColumneddQOSUnicastLocalread-writecurrentEDD Series card QOS Storm Control Configuration- Unicast 0: NO 1: YES
1.3.6.1.4.1.4756.20.440.20.1.840ColumneddQOSUnicastRateLocalread-writecurrentEDD Series card QOS Storm Control Configuration- Unicast Rate The rate unit is packets per second (pps). 0: 1 1: 2 2: 4 3: 8 4: 16 5: 32 6: 64 7: 128 8: 256 9:…
1.3.6.1.4.1.4756.20.440.20.1.841ColumneddQOSMulticastLocalread-writecurrentEDD Series card QOS Storm Control Configuration- Multicast 0: NO 1: YES
1.3.6.1.4.1.4756.20.440.20.1.842ColumneddQOSMulticastRateLocalread-writecurrentEDD Series card QOS Storm Control Configuration- Multicast The rate unit is packets per second (pps). 0: 1 1: 2 2: 4 3: 8 4: 16 5: 32 6: 64 7: 128 8: 256 9: 51…
1.3.6.1.4.1.4756.20.440.20.1.843ColumneddQOSBroadcastLocalread-writecurrentEDD Series card QOS Storm Control Configuration- Broadcast 0: NO 1: YES
1.3.6.1.4.1.4756.20.440.20.1.844ColumneddQOSBroadcastRateLocalread-writecurrentEDD Series card QOS Storm Control Configuration- Broadcast The rate unit is packets per second (pps). 0: 1 1: 2 2: 4 3: 8 4: 16 5: 32 6: 64 7: 128 8: 256 9: 51…
1.3.6.1.4.1.4756.20.440.20.1.845ColumneddL2CPPort1DMAC0180C2000000Localread-writecurrentEDD Series card Port 1 L2CP Mode 0180C2000000 0: Forward 1: Peer
1.3.6.1.4.1.4756.20.440.20.1.846ColumneddL2CPPort1DMAC0180C2000001Localread-writecurrentEDD Series card Port 1 L2CP Mode 0180C2000001 0: Forward 1: Peer
1.3.6.1.4.1.4756.20.440.20.1.847ColumneddL2CPPort1DMAC0180C2000002Localread-writecurrentEDD Series card Port 1 L2CP Mode 0180C2000002 0: Forward 1: Peer
1.3.6.1.4.1.4756.20.440.20.1.848ColumneddL2CPPort1DMAC0180C2000003Localread-writecurrentEDD Series card Port 1 L2CP Mode 0180C2000003 0: Forward 1: Peer
1.3.6.1.4.1.4756.20.440.20.1.849ColumneddL2CPPort1DMAC0180C2000004Localread-writecurrentEDD Series card Port 1 L2CP Mode 0180C2000004 0: Forward 1: Peer
1.3.6.1.4.1.4756.20.440.20.1.850ColumneddL2CPPort1DMAC0180C2000005Localread-writecurrentEDD Series card Port 1 L2CP Mode 0180C2000005 0: Forward 1: Peer
1.3.6.1.4.1.4756.20.440.20.1.851ColumneddL2CPPort1DMAC0180C2000006Localread-writecurrentEDD Series card Port 1 L2CP Mode 0180C2000006 0: Forward 1: Peer
1.3.6.1.4.1.4756.20.440.20.1.852ColumneddL2CPPort1DMAC0180C2000007Localread-writecurrentEDD Series card Port 1 L2CP Mode 0180C2000007 0: Forward 1: Peer
1.3.6.1.4.1.4756.20.440.20.1.853ColumneddL2CPPort1DMAC0180C2000008Localread-writecurrentEDD Series card Port 1 L2CP Mode 0180C2000008 0: Forward 1: Peer
1.3.6.1.4.1.4756.20.440.20.1.854ColumneddL2CPPort1DMAC0180C2000009Localread-writecurrentEDD Series card Port 1 L2CP Mode 0180C2000009 0: Forward 1: Peer
1.3.6.1.4.1.4756.20.440.20.1.855ColumneddL2CPPort1DMAC0180C200000ALocalread-writecurrentEDD Series card Port 1 L2CP Mode 0180C200000A 0: Forward 1: Peer
1.3.6.1.4.1.4756.20.440.20.1.856ColumneddL2CPPort1DMAC0180C200000BLocalread-writecurrentEDD Series card Port 1 L2CP Mode 0180C200000B 0: Forward 1: Peer
1.3.6.1.4.1.4756.20.440.20.1.857ColumneddL2CPPort1DMAC0180C200000CLocalread-writecurrentEDD Series card Port 1 L2CP Mode 0180C200000C 0: Forward 1: Peer
1.3.6.1.4.1.4756.20.440.20.1.858ColumneddL2CPPort1DMAC0180C200000DLocalread-writecurrentEDD Series card Port 1 L2CP Mode 0180C200000D 0: Forward 1: Peer
1.3.6.1.4.1.4756.20.440.20.1.859ColumneddL2CPPort1DMAC0180C200000ELocalread-writecurrentEDD Series card Port 1 L2CP Mode 0180C200000E 0: Forward 1: Peer
1.3.6.1.4.1.4756.20.440.20.1.860ColumneddL2CPPort1DMAC0180C200000FLocalread-writecurrentEDD Series card Port 1 L2CP Mode 0180C200000F 0: Forward 1: Peer
1.3.6.1.4.1.4756.20.440.20.1.861ColumneddL2CPPort1DMAC0180C2000010Localread-writecurrentEDD Series card Port 1 L2CP Mode 0180C2000010 0: Forward 1: Peer
1.3.6.1.4.1.4756.20.440.20.1.862ColumneddL2CPPort1DMAC0180C2000020Localread-writecurrentEDD Series card Port 1 L2CP Mode 0180C2000020 0: Forward 1: Peer
1.3.6.1.4.1.4756.20.440.20.1.863ColumneddL2CPPort1DMAC0180C2000021Localread-writecurrentEDD Series card Port 1 L2CP Mode 0180C2000021 0: Forward 1: Peer
1.3.6.1.4.1.4756.20.440.20.1.864ColumneddL2CPPort1DMAC0180C2000022Localread-writecurrentEDD Series card Port 1 L2CP Mode 0180C2000022 0: Forward 1: Peer
1.3.6.1.4.1.4756.20.440.20.1.865ColumneddL2CPPort1DMAC0180C2000023Localread-writecurrentEDD Series card Port 1 L2CP Mode 0180C2000023 0: Forward 1: Peer
1.3.6.1.4.1.4756.20.440.20.1.866ColumneddL2CPPort1DMAC0180C2000024Localread-writecurrentEDD Series card Port 1 L2CP Mode 0180C2000024 0: Forward 1: Peer
1.3.6.1.4.1.4756.20.440.20.1.867ColumneddL2CPPort1DMAC0180C2000025Localread-writecurrentEDD Series card Port 1 L2CP Mode 0180C2000025 0: Forward 1: Peer
1.3.6.1.4.1.4756.20.440.20.1.868ColumneddL2CPPort1DMAC0180C2000026Localread-writecurrentEDD Series card Port 1 L2CP Mode 0180C2000026 0: Forward 1: Peer
1.3.6.1.4.1.4756.20.440.20.1.869ColumneddL2CPPort1DMAC0180C2000027Localread-writecurrentEDD Series card Port 1 L2CP Mode 0180C2000027 0: Forward 1: Peer
1.3.6.1.4.1.4756.20.440.20.1.870ColumneddL2CPPort1DMAC0180C2000028Localread-writecurrentEDD Series card Port 1 L2CP Mode 0180C2000028 0: Forward 1: Peer
1.3.6.1.4.1.4756.20.440.20.1.871ColumneddL2CPPort1DMAC0180C2000029Localread-writecurrentEDD Series card Port 1 L2CP Mode 0180C2000029 0: Forward 1: Peer
1.3.6.1.4.1.4756.20.440.20.1.872ColumneddL2CPPort1DMAC0180C200002ALocalread-writecurrentEDD Series card Port 1 L2CP Mode 0180C200002A 0: Forward 1: Peer
1.3.6.1.4.1.4756.20.440.20.1.873ColumneddL2CPPort1DMAC0180C200002BLocalread-writecurrentEDD Series card Port 1 L2CP Mode 0180C200002B 0: Forward 1: Peer
1.3.6.1.4.1.4756.20.440.20.1.874ColumneddL2CPPort1DMAC0180C200002CLocalread-writecurrentEDD Series card Port 1 L2CP Mode 0180C200002C 0: Forward 1: Peer
1.3.6.1.4.1.4756.20.440.20.1.875ColumneddL2CPPort1DMAC0180C200002DLocalread-writecurrentEDD Series card Port 1 L2CP Mode 0180C200002D 0: Forward 1: Peer
1.3.6.1.4.1.4756.20.440.20.1.876ColumneddL2CPPort1DMAC0180C200002ELocalread-writecurrentEDD Series card Port 1 L2CP Mode 0180C200002E 0: Forward 1: Peer
1.3.6.1.4.1.4756.20.440.20.1.877ColumneddL2CPPort1DMAC0180C200002FLocalread-writecurrentEDD Series card Port 1 L2CP Mode 0180C200002F 0: Forward 1: Peer
1.3.6.1.4.1.4756.20.440.20.1.878ColumneddL2CPPort2DMAC0180C2000000Localread-writecurrentEDD Series card Port 2 L2CP Mode 0180C2000000 0: Forward 1: Peer
1.3.6.1.4.1.4756.20.440.20.1.879ColumneddL2CPPort2DMAC0180C2000001Localread-writecurrentEDD Series card Port 2 L2CP Mode 0180C2000001 0: Forward 1: Peer
1.3.6.1.4.1.4756.20.440.20.1.880ColumneddL2CPPort2DMAC0180C2000002Localread-writecurrentEDD Series card Port 2 L2CP Mode 0180C2000002 0: Forward 1: Peer
1.3.6.1.4.1.4756.20.440.20.1.881ColumneddL2CPPort2DMAC0180C2000003Localread-writecurrentEDD Series card Port 2 L2CP Mode 0180C2000003 0: Forward 1: Peer
1.3.6.1.4.1.4756.20.440.20.1.882ColumneddL2CPPort2DMAC0180C2000004Localread-writecurrentEDD Series card Port 2 L2CP Mode 0180C2000004 0: Forward 1: Peer
1.3.6.1.4.1.4756.20.440.20.1.883ColumneddL2CPPort2DMAC0180C2000005Localread-writecurrentEDD Series card Port 2 L2CP Mode 0180C2000005 0: Forward 1: Peer
1.3.6.1.4.1.4756.20.440.20.1.884ColumneddL2CPPort2DMAC0180C2000006Localread-writecurrentEDD Series card Port 2 L2CP Mode 0180C2000006 0: Forward 1: Peer
1.3.6.1.4.1.4756.20.440.20.1.885ColumneddL2CPPort2DMAC0180C2000007Localread-writecurrentEDD Series card Port 2 L2CP Mode 0180C2000007 0: Forward 1: Peer
1.3.6.1.4.1.4756.20.440.20.1.886ColumneddL2CPPort2DMAC0180C2000008Localread-writecurrentEDD Series card Port 2 L2CP Mode 0180C2000008 0: Forward 1: Peer
1.3.6.1.4.1.4756.20.440.20.1.887ColumneddL2CPPort2DMAC0180C2000009Localread-writecurrentEDD Series card Port 2 L2CP Mode 0180C2000009 0: Forward 1: Peer
1.3.6.1.4.1.4756.20.440.20.1.888ColumneddL2CPPort2DMAC0180C200000ALocalread-writecurrentEDD Series card Port 2 L2CP Mode 0180C200000A 0: Forward 1: Peer
1.3.6.1.4.1.4756.20.440.20.1.889ColumneddL2CPPort2DMAC0180C200000BLocalread-writecurrentEDD Series card Port 2 L2CP Mode 0180C200000B 0: Forward 1: Peer
1.3.6.1.4.1.4756.20.440.20.1.890ColumneddL2CPPort2DMAC0180C200000CLocalread-writecurrentEDD Series card Port 2 L2CP Mode 0180C200000C 0: Forward 1: Peer
1.3.6.1.4.1.4756.20.440.20.1.891ColumneddL2CPPort2DMAC0180C200000DLocalread-writecurrentEDD Series card Port 2 L2CP Mode 0180C200000A 0: Forward 1: Peer
1.3.6.1.4.1.4756.20.440.20.1.892ColumneddL2CPPort2DMAC0180C200000ELocalread-writecurrentEDD Series card Port 2 L2CP Mode 0180C200000E 0: Forward 1: Peer
1.3.6.1.4.1.4756.20.440.20.1.893ColumneddL2CPPort2DMAC0180C200000FLocalread-writecurrentEDD Series card Port 2 L2CP Mode 0180C200000F 0: Forward 1: Peer
1.3.6.1.4.1.4756.20.440.20.1.894ColumneddL2CPPort2DMAC0180C2000010Localread-writecurrentEDD Series card Port 2 L2CP Mode 0180C2000010 0: Forward 1: Peer
1.3.6.1.4.1.4756.20.440.20.1.895ColumneddL2CPPort2DMAC0180C2000020Localread-writecurrentEDD Series card Port 2 L2CP Mode 0180C2000020 0: Forward 1: Peer
1.3.6.1.4.1.4756.20.440.20.1.896ColumneddL2CPPort2DMAC0180C2000021Localread-writecurrentEDD Series card Port 2 L2CP Mode 0180C2000021 0: Forward 1: Peer
1.3.6.1.4.1.4756.20.440.20.1.897ColumneddL2CPPort2DMAC0180C2000022Localread-writecurrentEDD Series card Port 2 L2CP Mode 0180C2000022 0: Forward 1: Peer
1.3.6.1.4.1.4756.20.440.20.1.898ColumneddL2CPPort2DMAC0180C2000023Localread-writecurrentEDD Series card Port 2 L2CP Mode 0180C2000023 0: Forward 1: Peer
1.3.6.1.4.1.4756.20.440.20.1.899ColumneddL2CPPort2DMAC0180C2000024Localread-writecurrentEDD Series card Port 2 L2CP Mode 0180C2000024 0: Forward 1: Peer
1.3.6.1.4.1.4756.20.440.20.1.900ColumneddL2CPPort2DMAC0180C2000025Localread-writecurrentEDD Series card Port 2 L2CP Mode 0180C2000025 0: Forward 1: Peer
1.3.6.1.4.1.4756.20.440.20.1.901ColumneddL2CPPort2DMAC0180C2000026Localread-writecurrentEDD Series card Port 2 L2CP Mode 0180C2000026 0: Forward 1: Peer
1.3.6.1.4.1.4756.20.440.20.1.902ColumneddL2CPPort2DMAC0180C2000027Localread-writecurrentEDD Series card Port 2 L2CP Mode 0180C2000027 0: Forward 1: Peer
1.3.6.1.4.1.4756.20.440.20.1.903ColumneddL2CPPort2DMAC0180C2000028Localread-writecurrentEDD Series card Port 2 L2CP Mode 0180C2000028 0: Forward 1: Peer
1.3.6.1.4.1.4756.20.440.20.1.904ColumneddL2CPPort2DMAC0180C2000029Localread-writecurrentEDD Series card Port 2 L2CP Mode 0180C2000029 0: Forward 1: Peer
1.3.6.1.4.1.4756.20.440.20.1.905ColumneddL2CPPort2DMAC0180C200002ALocalread-writecurrentEDD Series card Port 2 L2CP Mode 0180C200002A 0: Forward 1: Peer
1.3.6.1.4.1.4756.20.440.20.1.906ColumneddL2CPPort2DMAC0180C200002BLocalread-writecurrentEDD Series card Port 2 L2CP Mode 0180C200002B 0: Forward 1: Peer
1.3.6.1.4.1.4756.20.440.20.1.907ColumneddL2CPPort2DMAC0180C200002CLocalread-writecurrentEDD Series card Port 2 L2CP Mode 0180C200002C 0: Forward 1: Peer
1.3.6.1.4.1.4756.20.440.20.1.908ColumneddL2CPPort2DMAC0180C200002DLocalread-writecurrentEDD Series card Port 2 L2CP Mode 0180C200002D 0: Forward 1: Peer
1.3.6.1.4.1.4756.20.440.20.1.909ColumneddL2CPPort2DMAC0180C200002ELocalread-writecurrentEDD Series card Port 2 L2CP Mode 0180C200002E 0: Forward 1: Peer
1.3.6.1.4.1.4756.20.440.20.1.910ColumneddL2CPPort2DMAC0180C200002FLocalread-writecurrentEDD Series card Port 2 L2CP Mode 0180C200002F 0: Forward 1: Peer
1.3.6.1.4.1.4756.20.440.20.1.911ColumneddL2CPPort3DMAC0180C2000000Localread-writecurrentEDD Series card Port 3 L2CP Mode 0180C2000000 0: Forward 1: Peer
1.3.6.1.4.1.4756.20.440.20.1.912ColumneddL2CPPort3DMAC0180C2000001Localread-writecurrentEDD Series card Port 3 L2CP Mode 0180C2000001 0: Forward 1: Peer
1.3.6.1.4.1.4756.20.440.20.1.913ColumneddL2CPPort3DMAC0180C2000002Localread-writecurrentEDD Series card Port 3 L2CP Mode 0180C2000002 0: Forward 1: Peer
1.3.6.1.4.1.4756.20.440.20.1.914ColumneddL2CPPort3DMAC0180C2000003Localread-writecurrentEDD Series card Port 3 L2CP Mode 0180C2000003 0: Forward 1: Peer
1.3.6.1.4.1.4756.20.440.20.1.915ColumneddL2CPPort3DMAC0180C2000004Localread-writecurrentEDD Series card Port 3 L2CP Mode 0180C2000004 0: Forward 1: Peer
1.3.6.1.4.1.4756.20.440.20.1.916ColumneddL2CPPort3DMAC0180C2000005Localread-writecurrentEDD Series card Port 3 L2CP Mode 0180C2000005 0: Forward 1: Peer
1.3.6.1.4.1.4756.20.440.20.1.917ColumneddL2CPPort3DMAC0180C2000006Localread-writecurrentEDD Series card Port 3 L2CP Mode 0180C2000006 0: Forward 1: Peer
1.3.6.1.4.1.4756.20.440.20.1.918ColumneddL2CPPort3DMAC0180C2000007Localread-writecurrentEDD Series card Port 3 L2CP Mode 0180C2000007 0: Forward 1: Peer
1.3.6.1.4.1.4756.20.440.20.1.919ColumneddL2CPPort3DMAC0180C2000008Localread-writecurrentEDD Series card Port 3 L2CP Mode 0180C2000008 0: Forward 1: Peer
1.3.6.1.4.1.4756.20.440.20.1.920ColumneddL2CPPort3DMAC0180C2000009Localread-writecurrentEDD Series card Port 3 L2CP Mode 0180C2000009 0: Forward 1: Peer
1.3.6.1.4.1.4756.20.440.20.1.921ColumneddL2CPPort3DMAC0180C200000ALocalread-writecurrentEDD Series card Port 3 L2CP Mode 0180C200000A 0: Forward 1: Peer
1.3.6.1.4.1.4756.20.440.20.1.922ColumneddL2CPPort3DMAC0180C200000BLocalread-writecurrentEDD Series card Port 3 L2CP Mode 0180C200000B 0: Forward 1: Peer
1.3.6.1.4.1.4756.20.440.20.1.923ColumneddL2CPPort3DMAC0180C200000CLocalread-writecurrentEDD Series card Port 3 L2CP Mode 0180C200000C 0: Forward 1: Peer
1.3.6.1.4.1.4756.20.440.20.1.924ColumneddL2CPPort3DMAC0180C200000DLocalread-writecurrentEDD Series card Port 3 L2CP Mode 0180C200000D 0: Forward 1: Peer
1.3.6.1.4.1.4756.20.440.20.1.925ColumneddL2CPPort3DMAC0180C200000ELocalread-writecurrentEDD Series card Port 3 L2CP Mode 0180C200000E 0: Forward 1: Peer
1.3.6.1.4.1.4756.20.440.20.1.926ColumneddL2CPPort3DMAC0180C200000FLocalread-writecurrentEDD Series card Port 3 L2CP Mode 0180C200000F 0: Forward 1: Peer
1.3.6.1.4.1.4756.20.440.20.1.927ColumneddL2CPPort3DMAC0180C2000010Localread-writecurrentEDD Series card Port 3 L2CP Mode 0180C2000010 0: Forward 1: Peer
1.3.6.1.4.1.4756.20.440.20.1.928ColumneddL2CPPort3DMAC0180C2000020Localread-writecurrentEDD Series card Port 3 L2CP Mode 0180C2000020 0: Forward 1: Peer
1.3.6.1.4.1.4756.20.440.20.1.929ColumneddL2CPPort3DMAC0180C2000021Localread-writecurrentEDD Series card Port 3 L2CP Mode 0180C2000021 0: Forward 1: Peer
1.3.6.1.4.1.4756.20.440.20.1.930ColumneddL2CPPort3DMAC0180C2000022Localread-writecurrentEDD Series card Port 3 L2CP Mode 0180C2000022 0: Forward 1: Peer
1.3.6.1.4.1.4756.20.440.20.1.931ColumneddL2CPPort3DMAC0180C2000023Localread-writecurrentEDD Series card Port 3 L2CP Mode 0180C2000023 0: Forward 1: Peer
1.3.6.1.4.1.4756.20.440.20.1.932ColumneddL2CPPort3DMAC0180C2000024Localread-writecurrentEDD Series card Port 3 L2CP Mode 0180C2000024 0: Forward 1: Peer
1.3.6.1.4.1.4756.20.440.20.1.933ColumneddL2CPPort3DMAC0180C2000025Localread-writecurrentEDD Series card Port 3 L2CP Mode 0180C2000025 0: Forward 1: Peer
1.3.6.1.4.1.4756.20.440.20.1.934ColumneddL2CPPort3DMAC0180C2000026Localread-writecurrentEDD Series card Port 3 L2CP Mode 0180C2000026 0: Forward 1: Peer
1.3.6.1.4.1.4756.20.440.20.1.935ColumneddL2CPPort3DMAC0180C2000027Localread-writecurrentEDD Series card Port 3 L2CP Mode 0180C2000027 0: Forward 1: Peer
1.3.6.1.4.1.4756.20.440.20.1.936ColumneddL2CPPort3DMAC0180C2000028Localread-writecurrentEDD Series card Port 3 L2CP Mode 0180C2000028 0: Forward 1: Peer
1.3.6.1.4.1.4756.20.440.20.1.937ColumneddL2CPPort3DMAC0180C2000029Localread-writecurrentEDD Series card Port 3 L2CP Mode 0180C2000029 0: Forward 1: Peer
1.3.6.1.4.1.4756.20.440.20.1.938ColumneddL2CPPort3DMAC0180C200002ALocalread-writecurrentEDD Series card Port 3 L2CP Mode 0180C200002A 0: Forward 1: Peer
1.3.6.1.4.1.4756.20.440.20.1.939ColumneddL2CPPort3DMAC0180C200002BLocalread-writecurrentEDD Series card Port 3 L2CP Mode 0180C200002B 0: Forward 1: Peer
1.3.6.1.4.1.4756.20.440.20.1.940ColumneddL2CPPort3DMAC0180C200002CLocalread-writecurrentEDD Series card Port 3 L2CP Mode 0180C200002C 0: Forward 1: Peer
1.3.6.1.4.1.4756.20.440.20.1.941ColumneddL2CPPort3DMAC0180C200002DLocalread-writecurrentEDD Series card Port 3 L2CP Mode 0180C200002D 0: Forward 1: Peer
1.3.6.1.4.1.4756.20.440.20.1.942ColumneddL2CPPort3DMAC0180C200002ELocalread-writecurrentEDD Series card Port 3 L2CP Mode 0180C200002E 0: Forward 1: Peer
1.3.6.1.4.1.4756.20.440.20.1.943ColumneddL2CPPort3DMAC0180C200002FLocalread-writecurrentEDD Series card Port 3 L2CP Mode 0180C200002F 0: Forward 1: Peer
1.3.6.1.4.1.4756.20.440.20.1.944ColumneddL2CPPort4DMAC0180C2000000Localread-writecurrentEDD Series card Port 4 L2CP Mode 0180C2000000 0: Forward 1: Peer
1.3.6.1.4.1.4756.20.440.20.1.945ColumneddL2CPPort4DMAC0180C2000001Localread-writecurrentEDD Series card Port 4 L2CP Mode 0180C2000001 0: Forward 1: Peer
1.3.6.1.4.1.4756.20.440.20.1.946ColumneddL2CPPort4DMAC0180C2000002Localread-writecurrentEDD Series card Port 4 L2CP Mode 0180C2000002 0: Forward 1: Peer
1.3.6.1.4.1.4756.20.440.20.1.947ColumneddL2CPPort4DMAC0180C2000003Localread-writecurrentEDD Series card Port 4 L2CP Mode 0180C2000003 0: Forward 1: Peer
1.3.6.1.4.1.4756.20.440.20.1.948ColumneddL2CPPort4DMAC0180C2000004Localread-writecurrentEDD Series card Port 4 L2CP Mode 0180C2000004 0: Forward 1: Peer
1.3.6.1.4.1.4756.20.440.20.1.949ColumneddL2CPPort4DMAC0180C2000005Localread-writecurrentEDD Series card Port 4 L2CP Mode 0180C2000005 0: Forward 1: Peer
1.3.6.1.4.1.4756.20.440.20.1.950ColumneddL2CPPort4DMAC0180C2000006Localread-writecurrentEDD Series card Port 4 L2CP Mode 0180C2000006 0: Forward 1: Peer
1.3.6.1.4.1.4756.20.440.20.1.951ColumneddL2CPPort4DMAC0180C2000007Localread-writecurrentEDD Series card Port 4 L2CP Mode 0180C2000007 0: Forward 1: Peer
1.3.6.1.4.1.4756.20.440.20.1.952ColumneddL2CPPort4DMAC0180C2000008Localread-writecurrentEDD Series card Port 4 L2CP Mode 0180C2000008 0: Forward 1: Peer
1.3.6.1.4.1.4756.20.440.20.1.953ColumneddL2CPPort4DMAC0180C2000009Localread-writecurrentEDD Series card Port 4 L2CP Mode 0180C2000009 0: Forward 1: Peer
1.3.6.1.4.1.4756.20.440.20.1.954ColumneddL2CPPort4DMAC0180C200000ALocalread-writecurrentEDD Series card Port 4 L2CP Mode 0180C200000A 0: Forward 1: Peer
1.3.6.1.4.1.4756.20.440.20.1.955ColumneddL2CPPort4DMAC0180C200000BLocalread-writecurrentEDD Series card Port 4 L2CP Mode 0180C200000B 0: Forward 1: Peer
1.3.6.1.4.1.4756.20.440.20.1.956ColumneddL2CPPort4DMAC0180C200000CLocalread-writecurrentEDD Series card Port 4 L2CP Mode 0180C200000C 0: Forward 1: Peer
1.3.6.1.4.1.4756.20.440.20.1.957ColumneddL2CPPort4DMAC0180C200000DLocalread-writecurrentEDD Series card Port 4 L2CP Mode 0180C200000D 0: Forward 1: Peer
1.3.6.1.4.1.4756.20.440.20.1.958ColumneddL2CPPort4DMAC0180C200000ELocalread-writecurrentEDD Series card Port 4 L2CP Mode 0180C200000E 0: Forward 1: Peer
1.3.6.1.4.1.4756.20.440.20.1.959ColumneddL2CPPort4DMAC0180C200000FLocalread-writecurrentEDD Series card Port 4 L2CP Mode 0180C200000F 0: Forward 1: Peer
1.3.6.1.4.1.4756.20.440.20.1.960ColumneddL2CPPort4DMAC0180C2000010Localread-writecurrentEDD Series card Port 4 L2CP Mode 0180C2000010 0: Forward 1: Peer
1.3.6.1.4.1.4756.20.440.20.1.961ColumneddL2CPPort4DMAC0180C2000020Localread-writecurrentEDD Series card Port 4 L2CP Mode 0180C2000020 0: Forward 1: Peer
1.3.6.1.4.1.4756.20.440.20.1.962ColumneddL2CPPort4DMAC0180C2000021Localread-writecurrentEDD Series card Port 4 L2CP Mode 0180C2000021 0: Forward 1: Peer
1.3.6.1.4.1.4756.20.440.20.1.963ColumneddL2CPPort4DMAC0180C2000022Localread-writecurrentEDD Series card Port 4 L2CP Mode 0180C2000022 0: Forward 1: Peer
1.3.6.1.4.1.4756.20.440.20.1.964ColumneddL2CPPort4DMAC0180C2000023Localread-writecurrentEDD Series card Port 4 L2CP Mode 0180C2000023 0: Forward 1: Peer
1.3.6.1.4.1.4756.20.440.20.1.965ColumneddL2CPPort4DMAC0180C2000024Localread-writecurrentEDD Series card Port 4 L2CP Mode 0180C2000024 0: Forward 1: Peer
1.3.6.1.4.1.4756.20.440.20.1.966ColumneddL2CPPort4DMAC0180C2000025Localread-writecurrentEDD Series card Port 4 L2CP Mode 0180C2000025 0: Forward 1: Peer
1.3.6.1.4.1.4756.20.440.20.1.967ColumneddL2CPPort4DMAC0180C2000026Localread-writecurrentEDD Series card Port 4 L2CP Mode 0180C2000026 0: Forward 1: Peer
1.3.6.1.4.1.4756.20.440.20.1.968ColumneddL2CPPort4DMAC0180C2000027Localread-writecurrentEDD Series card Port 4 L2CP Mode 0180C2000027 0: Forward 1: Peer
1.3.6.1.4.1.4756.20.440.20.1.969ColumneddL2CPPort4DMAC0180C2000028Localread-writecurrentEDD Series card Port 4 L2CP Mode 0180C2000028 0: Forward 1: Peer
1.3.6.1.4.1.4756.20.440.20.1.970ColumneddL2CPPort4DMAC0180C2000029Localread-writecurrentEDD Series card Port 4 L2CP Mode 0180C2000029 0: Forward 1: Peer
1.3.6.1.4.1.4756.20.440.20.1.971ColumneddL2CPPort4DMAC0180C200002ALocalread-writecurrentEDD Series card Port 4 L2CP Mode 0180C200002A 0: Forward 1: Peer
1.3.6.1.4.1.4756.20.440.20.1.972ColumneddL2CPPort4DMAC0180C200002BLocalread-writecurrentEDD Series card Port 4 L2CP Mode 0180C200002B 0: Forward 1: Peer
1.3.6.1.4.1.4756.20.440.20.1.973ColumneddL2CPPort4DMAC0180C200002CLocalread-writecurrentEDD Series card Port 4 L2CP Mode 0180C200002C 0: Forward 1: Peer
1.3.6.1.4.1.4756.20.440.20.1.974ColumneddL2CPPort4DMAC0180C200002DLocalread-writecurrentEDD Series card Port 4 L2CP Mode 0180C200002D 0: Forward 1: Peer
1.3.6.1.4.1.4756.20.440.20.1.975ColumneddL2CPPort4DMAC0180C200002ELocalread-writecurrentEDD Series card Port 4 L2CP Mode 0180C200002E 0: Forward 1: Peer
1.3.6.1.4.1.4756.20.440.20.1.976ColumneddL2CPPort4DMAC0180C200002FLocalread-writecurrentEDD Series card Port 4 L2CP Mode 0180C200002F 0: Forward 1: Peer
1.3.6.1.4.1.4756.20.440.20.1.977ColumneddPort1MEPInstanceLocalread-writecurrentEDD Series card Port 1 MEP Instance 'MEP ID' must be an integer value between 0 and 8191.
1.3.6.1.4.1.4756.20.440.20.1.978ColumneddPort1MEPLogicLocalread-writecurrentEDD Series card Port 1 MEP Logic 0: And 1: OR
1.3.6.1.4.1.4756.20.440.20.1.979ColumneddPort2MEPInstanceLocalread-writecurrentEDD Series card Port 2 MEP Instance 'MEP ID' must be an integer value between 0 and 8191.
1.3.6.1.4.1.4756.20.440.20.1.980ColumneddPort2MEPLogicLocalread-writecurrentEDD Series card Port 2 MEP Logic 0: And 1: OR
1.3.6.1.4.1.4756.20.440.20.1.981ColumneddPort3MEPInstanceLocalread-writecurrentEDD Series card Port 3 MEP Instance 'MEP ID' must be an integer value between 0 and 8191.
1.3.6.1.4.1.4756.20.440.20.1.982ColumneddPort3MEPLogicLocalread-writecurrentEDD Series card Port 3 MEP Logic 0: And 1: OR
1.3.6.1.4.1.4756.20.440.20.1.983ColumneddPort4MEPInstanceLocalread-writecurrentEDD Series card Port 4 MEP Instance 'MEP ID' must be an integer value between 0 and 8191.
1.3.6.1.4.1.4756.20.440.20.1.984ColumneddPort4MEPLogicLocalread-writecurrentEDD Series card Port 4 MEP Logic 0: And 1: OR
1.3.6.1.4.1.4756.20.441NodeeddRemoteACards
1.3.6.1.4.1.4756.20.441.20TableeddRemoteATablenot-accessiblecurrentA list of RemoteA FRM220-EDD series card entries.
1.3.6.1.4.1.4756.20.441.20.1RoweddRemoteAEntrynot-accessiblecurrentAn entry containing management information applicable to a particular FRM220-EDD series card.
1.3.6.1.4.1.4756.20.441.20.1.1ColumneddChassisIndexRemoteAread-onlycurrentA unique value for each card. It starts from 0 to 9 contiguously.
1.3.6.1.4.1.4756.20.441.20.1.2ColumneddSlotIndexRemoteAread-onlycurrentA unique value for each card. It starts from 1 to 20 contiguously.
1.3.6.1.4.1.4756.20.441.20.1.3ColumneddCardHWVerRemoteAread-onlycurrentEDD Series card hardware version x.xxx
1.3.6.1.4.1.4756.20.441.20.1.4ColumneddCardFWVerRemoteAread-onlycurrentEDD Series card firmware version x.xxx
1.3.6.1.4.1.4756.20.441.20.1.5ColumneddCardCPLDVerRemoteAread-onlycurrentEDD Series card CPLD version x.xxx
1.3.6.1.4.1.4756.20.441.20.1.6ColumneddCardFPGAVerRemoteAread-onlycurrentEDD Series card FPGA version x.xxx
1.3.6.1.4.1.4756.20.441.20.1.7ColumneddModelRemoteAread-onlycurrentCard Type: 0:MX210 1:MSW202
1.3.6.1.4.1.4756.20.441.20.1.8ColumneddPort1LinkstsRemoteAread-onlycurrentEDD Series card Port1 link status: 0:Link down 1:Link up
1.3.6.1.4.1.4756.20.441.20.1.9ColumneddPort1SpeedstsRemoteAread-onlycurrentEDD Series card Port1 speed status 10Base-T 100Base-Tx 1000Base-Tx 2.5G
1.3.6.1.4.1.4756.20.441.20.1.10ColumneddPort1DuplexstsRemoteAread-onlycurrentEDD Series card Port1 duplex status 0: Half 1: Full
1.3.6.1.4.1.4756.20.441.20.1.11ColumneddPort1RxPausestsRemoteAread-onlycurrentEDD Series card Port1 rx pause status 0: No 1: Yes
1.3.6.1.4.1.4756.20.441.20.1.12ColumneddPort1TxPausestsRemoteAread-onlycurrentEDD Series card Port1 tx pause status 0: No 1: Yes
1.3.6.1.4.1.4756.20.441.20.1.13ColumneddPort2LinkstsRemoteAread-onlycurrentEDD Series card Port2 link status: 0:Link down 1:Link up
1.3.6.1.4.1.4756.20.441.20.1.14ColumneddPort2SpeedstsRemoteAread-onlycurrentEDD Series card Port2 speed status 10Base-T 100Base-Tx 1000Base-Tx 2.5G
1.3.6.1.4.1.4756.20.441.20.1.15ColumneddPort2DuplexstsRemoteAread-onlycurrentEDD Series card Port2 duplex status 0: Half 1: Full
1.3.6.1.4.1.4756.20.441.20.1.16ColumneddPort2RxPausestsRemoteAread-onlycurrentEDD Series card Port2 rx pause status 0: No 1: Yes
1.3.6.1.4.1.4756.20.441.20.1.17ColumneddPort2TxPausestsRemoteAread-onlycurrentEDD Series card Port2 tx pause status 0: No 1: Yes
1.3.6.1.4.1.4756.20.441.20.1.18ColumneddPort3LinkstsRemoteAread-onlycurrentEDD Series card Port3 link status: 0:Link down 1:Link up
1.3.6.1.4.1.4756.20.441.20.1.19ColumneddPort3SpeedstsRemoteAread-onlycurrentEDD Series card Port3 speed status 10Base-T 100Base-Tx 1000Base-Tx
1.3.6.1.4.1.4756.20.441.20.1.20ColumneddPort3DuplexstsRemoteAread-onlycurrentEDD Series card Port3 duplex status 0: Half 1: Full
1.3.6.1.4.1.4756.20.441.20.1.21ColumneddPort3RxPausestsRemoteAread-onlycurrentEDD Series card Port3 rx pause status 0: No 1: Yes
1.3.6.1.4.1.4756.20.441.20.1.22ColumneddPort3TxPausestsRemoteAread-onlycurrentEDD Series card Port3 tx pause status 0: No 1: Yes
1.3.6.1.4.1.4756.20.441.20.1.23ColumneddPort4LinkstsRemoteAread-onlycurrentEDD Series card Port4 link status: 0:Link down 1:Link up
1.3.6.1.4.1.4756.20.441.20.1.24ColumneddPort4SpeedstsRemoteAread-onlycurrentEDD Series card Port4 speed status 10Base-T 100Base-Tx 1000Base-Tx
1.3.6.1.4.1.4756.20.441.20.1.25ColumneddPort4DuplexstsRemoteAread-onlycurrentEDD Series card Port4 duplex status 0: Half 1: Full
1.3.6.1.4.1.4756.20.441.20.1.26ColumneddPort4RxPausestsRemoteAread-onlycurrentEDD Series card Port4 rx pause status 0: No 1: Yes
1.3.6.1.4.1.4756.20.441.20.1.27ColumneddPort4TxPausestsRemoteAread-onlycurrentEDD Series card Port4 tx pause status 0: No 1: Yes
1.3.6.1.4.1.4756.20.441.20.1.28ColumneddPort1SpeedConfRemoteAread-writecurrentEDD Series card Port1 speed config 0: disable 1: auto 2: 100M FDX 3: 1G FDX 4: 2.5G FDX
1.3.6.1.4.1.4756.20.441.20.1.29ColumneddPort1flowConrolRemoteAread-writecurrentEDD Series card Port1 flow control config 0: no 1: yes
1.3.6.1.4.1.4756.20.441.20.1.30ColumneddPort1MaxFrameRemoteAread-writecurrentEDD Series card Port1 max frame config
1.3.6.1.4.1.4756.20.441.20.1.31ColumneddPort2SpeedConfRemoteAread-writecurrentEDD Series card Port2 speed config 0: disable 1: auto 2: 100M FDX 3: 1G FDX 4: 2.5G FDX
1.3.6.1.4.1.4756.20.441.20.1.32ColumneddPort2flowConrolRemoteAread-writecurrentEDD Series card Port2 flow control config 0: no 1: yes
1.3.6.1.4.1.4756.20.441.20.1.33ColumneddPort2MaxFrameRemoteAread-writecurrentEDD Series card Port2 max frame config
1.3.6.1.4.1.4756.20.441.20.1.34ColumneddPort3SpeedConfRemoteAread-writecurrentEDD Series card Port3 speed config 0: disable 1: auto 2: 10M HDX 3: 10M FDX 4: 100M HDX 5: 100M FDX 6: 1G FDX
1.3.6.1.4.1.4756.20.441.20.1.35ColumneddPort3flowConrolRemoteAread-writecurrentEDD Series card Port3 flow control config 0: no 1: yes
1.3.6.1.4.1.4756.20.441.20.1.36ColumneddPort3MaxFrameRemoteAread-writecurrentEDD Series card Port3 max frame config
1.3.6.1.4.1.4756.20.441.20.1.37ColumneddPort3CollisionModeRemoteAread-writecurrentEDD Series card Port3 collision mode config.(MSW202 only) 0: Discard 1: Restart
1.3.6.1.4.1.4756.20.441.20.1.38ColumneddPort4SpeedConfRemoteAread-writecurrentEDD Series card Port4 speed config 0: disable 1: auto 2: 10M HDX 3: 10M FDX 4: 100M HDX 5: 100M FDX 6: 1G FDX
1.3.6.1.4.1.4756.20.441.20.1.39ColumneddPort4flowConrolRemoteAread-writecurrentEDD Series card Port4 flow control config 0: no 1: yes
1.3.6.1.4.1.4756.20.441.20.1.40ColumneddPort4MaxFrameRemoteAread-writecurrentEDD Series card Port4 max frame config
1.3.6.1.4.1.4756.20.441.20.1.41ColumneddPort4CollisionModeRemoteAread-writecurrentEDD Series card Port4 collision mode config 0: Discard 1: Restart
1.3.6.1.4.1.4756.20.441.20.1.42ColumneddSaveStartupCongRemoteAread-writecurrentEDD Series card save start-up config 0: OFF 1: Action
1.3.6.1.4.1.4756.20.441.20.1.43ColumneddPortResetRemoteAread-writecurrentEDD Series card port reset 0: OFF 1: Action
1.3.6.1.4.1.4756.20.441.20.1.44ColumneddSetDefaultRemoteAread-writecurrentEDD Series card set to default config 0: OFF 1: Action
1.3.6.1.4.1.4756.20.441.20.1.45ColumneddMuxModeRemoteAread-writecurrentEDD Series card Mux mode (MX210 only) 0: Disable 1: Switch 2: Isolate 3: VLAN
1.3.6.1.4.1.4756.20.441.20.1.46ColumneddPort1PacketsRxRemoteAread-onlycurrentEDD Series card port1 traffic overview:: Packets Rx
1.3.6.1.4.1.4756.20.441.20.1.47ColumneddPort1PacketsTxRemoteAread-onlycurrentEDD Series card port1 traffic overview:: Packets Tx
1.3.6.1.4.1.4756.20.441.20.1.48ColumneddPort1BytesRxRemoteAread-onlycurrentEDD Series card port1 traffic overview:: Bytes Rx
1.3.6.1.4.1.4756.20.441.20.1.49ColumneddPort1BytesTxRemoteAread-onlycurrentEDD Series card port1 traffic overview:: Bytes Tx
1.3.6.1.4.1.4756.20.441.20.1.50ColumneddPort1ErrorsRxRemoteAread-onlycurrentEDD Series card port1 traffic overview:: Errors Rx
1.3.6.1.4.1.4756.20.441.20.1.51ColumneddPort1ErrorsTxRemoteAread-onlycurrentEDD Series card port1 traffic overview:: Errors Tx
1.3.6.1.4.1.4756.20.441.20.1.52ColumneddPort1DropsRxRemoteAread-onlycurrentEDD Series card port1 traffic overview:: Drops Rx
1.3.6.1.4.1.4756.20.441.20.1.53ColumneddPort1DropsTxRemoteAread-onlycurrentEDD Series card port1 traffic overview:: Drops Tx
1.3.6.1.4.1.4756.20.441.20.1.54ColumneddPort1FilteredRxRemoteAread-onlycurrentEDD Series card port1 traffic overview:: Filtered Rx
1.3.6.1.4.1.4756.20.441.20.1.55ColumneddPort2PacketsRxRemoteAread-onlycurrentEDD Series card port2 traffic overview:: Packets Rx
1.3.6.1.4.1.4756.20.441.20.1.56ColumneddPort2PacketsTxRemoteAread-onlycurrentEDD Series card port2 traffic overview:: Packets Tx
1.3.6.1.4.1.4756.20.441.20.1.57ColumneddPort2BytesRxRemoteAread-onlycurrentEDD Series card port2 traffic overview:: Bytes Rx
1.3.6.1.4.1.4756.20.441.20.1.58ColumneddPort2BytesTxRemoteAread-onlycurrentEDD Series card port2 traffic overview:: Bytes Tx
1.3.6.1.4.1.4756.20.441.20.1.59ColumneddPort2ErrorsRxRemoteAread-onlycurrentEDD Series card port2 traffic overview:: Errors Rx
1.3.6.1.4.1.4756.20.441.20.1.60ColumneddPort2ErrorsTxRemoteAread-onlycurrentEDD Series card port2 traffic overview:: Errors Tx
1.3.6.1.4.1.4756.20.441.20.1.61ColumneddPort2DropsRxRemoteAread-onlycurrentEDD Series card port2 traffic overview:: Drops Rx
1.3.6.1.4.1.4756.20.441.20.1.62ColumneddPort2DropsTxRemoteAread-onlycurrentEDD Series card port2 traffic overview:: Drops Tx
1.3.6.1.4.1.4756.20.441.20.1.63ColumneddPort2FilteredRxRemoteAread-onlycurrentEDD Series card port2 traffic overview:: Filtered Rx
1.3.6.1.4.1.4756.20.441.20.1.64ColumneddPort3PacketsRxRemoteAread-onlycurrentEDD Series card port3 traffic overview:: Packets Rx
1.3.6.1.4.1.4756.20.441.20.1.65ColumneddPort3PacketsTxRemoteAread-onlycurrentEDD Series card port3 traffic overview:: Packets Tx
1.3.6.1.4.1.4756.20.441.20.1.66ColumneddPort3BytesRxRemoteAread-onlycurrentEDD Series card port3 traffic overview:: Bytes Rx
1.3.6.1.4.1.4756.20.441.20.1.67ColumneddPort3BytesTxRemoteAread-onlycurrentEDD Series card port3 traffic overview:: Bytes Tx
1.3.6.1.4.1.4756.20.441.20.1.68ColumneddPort3ErrorsRxRemoteAread-onlycurrentEDD Series card port3 traffic overview:: Errors Rx
1.3.6.1.4.1.4756.20.441.20.1.69ColumneddPort3ErrorsTxRemoteAread-onlycurrentEDD Series card port3 traffic overview:: Errors Tx
1.3.6.1.4.1.4756.20.441.20.1.70ColumneddPort3DropsRxRemoteAread-onlycurrentEDD Series card port3 traffic overview:: Drops Rx
1.3.6.1.4.1.4756.20.441.20.1.71ColumneddPort3DropsTxRemoteAread-onlycurrentEDD Series card port3 traffic overview:: Drops Tx
1.3.6.1.4.1.4756.20.441.20.1.72ColumneddPort3FilteredRxRemoteAread-onlycurrentEDD Series card port3 traffic overview:: Filtered Rx
1.3.6.1.4.1.4756.20.441.20.1.73ColumneddPort4PacketsRxRemoteAread-onlycurrentEDD Series card port4 traffic overview:: Packets Rx
1.3.6.1.4.1.4756.20.441.20.1.74ColumneddPort4PacketsTxRemoteAread-onlycurrentEDD Series card port4 traffic overview:: Packets Tx
1.3.6.1.4.1.4756.20.441.20.1.75ColumneddPort4BytesRxRemoteAread-onlycurrentEDD Series card port4 traffic overview:: Bytes Rx
1.3.6.1.4.1.4756.20.441.20.1.76ColumneddPort4BytesTxRemoteAread-onlycurrentEDD Series card port4 traffic overview:: Bytes Tx
1.3.6.1.4.1.4756.20.441.20.1.77ColumneddPort4ErrorsRxRemoteAread-onlycurrentEDD Series card port4 traffic overview:: Errors Rx
1.3.6.1.4.1.4756.20.441.20.1.78ColumneddPort4ErrorsTxRemoteAread-onlycurrentEDD Series card port4 traffic overview:: Errors Tx
1.3.6.1.4.1.4756.20.441.20.1.79ColumneddPort4DropsRxRemoteAread-onlycurrentEDD Series card port4 traffic overview:: Drops Rx
1.3.6.1.4.1.4756.20.441.20.1.80ColumneddPort4DropsTxRemoteAread-onlycurrentEDD Series card port4 traffic overview:: Drops Tx
1.3.6.1.4.1.4756.20.441.20.1.81ColumneddPort4FilteredRxRemoteAread-onlycurrentEDD Series card port4 traffic overview:: Filtered Rx
1.3.6.1.4.1.4756.20.441.20.1.82ColumnedduRingInstanceAddRemoteAread-writecurrentEDD Series card Add a new uRing Instance. Syntax: <Instance ID> <ring|sub|chain> <port east> <port west> Instance ID must be either 1 or 2 port east , the valu…
1.3.6.1.4.1.4756.20.441.20.1.83ColumnedduRingInstanceDeleteRemoteAread-writecurrentEDD Series card Delete a uRing Instance. Syntax: <uRing Instance>
1.3.6.1.4.1.4756.20.441.20.1.84ColumnedduRingInst1IDRemoteAread-onlycurrentEDD Series card u-Ring instance1 ID
1.3.6.1.4.1.4756.20.441.20.1.85ColumnedduRingInst1typeRemoteAread-onlycurrentEDD Series card u-Ring instance1 type 0: u-Ring 1: Sub-Ring 2: u-Chain
1.3.6.1.4.1.4756.20.441.20.1.86ColumnedduRingInst1masterRemoteAread-writecurrentEDD Series card u-Ring instance1 master 0: No 1: Yes
1.3.6.1.4.1.4756.20.441.20.1.87ColumnedduRingInst1EastPortRemoteAread-onlycurrentEDD Series card u-Ring instance1 east port
1.3.6.1.4.1.4756.20.441.20.1.88ColumnedduRingInst1EastEdgeRemoteAread-writecurrentEDD Series card u-Ring instance1 east edge 0: No 1: Yes
1.3.6.1.4.1.4756.20.441.20.1.89ColumnedduRingInst1WestPortRemoteAread-onlycurrentEDD Series card u-Ring instance1 west port
1.3.6.1.4.1.4756.20.441.20.1.90ColumnedduRingInst1WestEdgeRemoteAread-writecurrentEDD Series card u-Ring instance1 west edge 0: No 1: Yes
1.3.6.1.4.1.4756.20.441.20.1.91ColumnedduRingInst2IDRemoteAread-onlycurrentEDD Series card u-Ring instance2 ID
1.3.6.1.4.1.4756.20.441.20.1.92ColumnedduRingInst2typeRemoteAread-onlycurrentEDD Series card u-Ring instance2 type 0: u-Ring 1: Sub-Ring 2: u-Chain
1.3.6.1.4.1.4756.20.441.20.1.93ColumnedduRingInst2masterRemoteAread-writecurrentEDD Series card u-Ring instance2 master 0: No 1: Yes
1.3.6.1.4.1.4756.20.441.20.1.94ColumnedduRingInst2EastPortRemoteAread-onlycurrentEDD Series card u-Ring instance2 east port
1.3.6.1.4.1.4756.20.441.20.1.95ColumnedduRingInst2EastEdgeRemoteAread-writecurrentEDD Series card u-Ring instance2 east edge 0: No 1: Yes
1.3.6.1.4.1.4756.20.441.20.1.96ColumnedduRingInst2WestPortRemoteAread-onlycurrentEDD Series card u-Ring instance2 west port
1.3.6.1.4.1.4756.20.441.20.1.97ColumnedduRingInst2WestEdgeRemoteAread-writecurrentEDD Series card u-Ring instance2 west edge 0: No 1: Yes
1.3.6.1.4.1.4756.20.441.20.1.98ColumnedduRingInst1IDstsRemoteAread-onlycurrentEDD Series card u-Ring Instance1 ID status
1.3.6.1.4.1.4756.20.441.20.1.99ColumnedduRingInst1typestsRemoteAread-onlycurrentEDD Series card u-Ring Type status
1.3.6.1.4.1.4756.20.441.20.1.100ColumnedduRingInst1rolestsRemoteAread-onlycurrentEDD Series card u-Ring Role status
1.3.6.1.4.1.4756.20.441.20.1.101ColumnedduRingInst1EastPortstsRemoteAread-onlycurrentEDD Series card u-Ring East port status
1.3.6.1.4.1.4756.20.441.20.1.102ColumnedduRingInst1EaststsRemoteAread-onlycurrentEDD Series card u-Ring East status
1.3.6.1.4.1.4756.20.441.20.1.103ColumnedduRingInst1EastEdgestsRemoteAread-onlycurrentEDD Series card u-Ring East edge status
1.3.6.1.4.1.4756.20.441.20.1.104ColumnedduRingInst1WestPortstsRemoteAread-onlycurrentEDD Series card u-Ring West edge status
1.3.6.1.4.1.4756.20.441.20.1.105ColumnedduRingInst1WeststsRemoteAread-onlycurrentEDD Series card u-Ring West status
1.3.6.1.4.1.4756.20.441.20.1.106ColumnedduRingInst1WestEdgestsRemoteAread-onlycurrentEDD Series card u-Ring West status
1.3.6.1.4.1.4756.20.441.20.1.107ColumnedduRingInst1healthystsRemoteAread-onlycurrentEDD Series card u-Ring healthy status None Fine Fault
1.3.6.1.4.1.4756.20.441.20.1.108ColumnedduRingInst2IDstsRemoteAread-onlycurrentEDD Series card u-Ring Instance2 ID status
1.3.6.1.4.1.4756.20.441.20.1.109ColumnedduRingInst2typestsRemoteAread-onlycurrentEDD Series card u-Ring Type status
1.3.6.1.4.1.4756.20.441.20.1.110ColumnedduRingInst2rolestsRemoteAread-onlycurrentEDD Series card u-Ring Role status
1.3.6.1.4.1.4756.20.441.20.1.111ColumnedduRingInst2EastPortstsRemoteAread-onlycurrentEDD Series card u-Ring East port status
1.3.6.1.4.1.4756.20.441.20.1.112ColumnedduRingInst2EaststsRemoteAread-onlycurrentEDD Series card u-Ring East status
1.3.6.1.4.1.4756.20.441.20.1.113ColumnedduRingInst2EastEdgestsRemoteAread-onlycurrentEDD Series card u-Ring East edge status
1.3.6.1.4.1.4756.20.441.20.1.114ColumnedduRingInst2WestPortstsRemoteAread-onlycurrentEDD Series card u-Ring West edge status
1.3.6.1.4.1.4756.20.441.20.1.115ColumnedduRingInst2WeststsRemoteAread-onlycurrentEDD Series card u-Ring West status
1.3.6.1.4.1.4756.20.441.20.1.116ColumnedduRingInst2WestEdgestsRemoteAread-onlycurrentEDD Series card u-Ring West status
1.3.6.1.4.1.4756.20.441.20.1.117ColumnedduRingInst2healthystsRemoteAread-onlycurrentEDD Series card u-Ring healthy status None Fine Fault
1.3.6.1.4.1.4756.20.441.20.1.118ColumneddDeviceActiveRemoteAread-onlycurrentEDD Series card u-Ring device active 0: Disable 1: Enable
1.3.6.1.4.1.4756.20.441.20.1.119ColumneddFx1DDRemoteAread-onlycurrentEDD Series card fiber port Digital Diagnostic function: 0:No 1:Yes
1.3.6.1.4.1.4756.20.441.20.1.120ColumneddFx1DDVendorRemoteAread-onlycurrentEDD Series card fiber port D/D information: Vendor name
1.3.6.1.4.1.4756.20.441.20.1.121ColumneddFx1DDPartNoRemoteAread-onlycurrentEDD Series card fiber port D/D information: Vendor part number
1.3.6.1.4.1.4756.20.441.20.1.122ColumneddFx1DDFiberTypeRemoteAread-onlycurrentEDD Series card fiber port D/D information: Fiber Type
1.3.6.1.4.1.4756.20.441.20.1.123ColumneddFx1DDWaveLenRemoteAread-onlycurrentEDD Series card fiber port D/D information: Wave length
1.3.6.1.4.1.4756.20.441.20.1.124ColumneddFx1DDWaveLen2RemoteAread-onlycurrentEDD Series card fiber port D/D information: Wave length 2
1.3.6.1.4.1.4756.20.441.20.1.125ColumneddFx1DDLinkLenRemoteAread-onlycurrentEDD Series card fiber port D/D information: Link length
1.3.6.1.4.1.4756.20.441.20.1.126ColumneddFx1DDLenUnitRemoteAread-onlycurrentEDD Series card fiber port D/D information: Length Unit
1.3.6.1.4.1.4756.20.441.20.1.127ColumneddFx1DDStatusRemoteAread-onlycurrentEDD Series card fiber port D/D information: Status Support
1.3.6.1.4.1.4756.20.441.20.1.128ColumneddFx1DDRxSensRemoteAread-onlycurrentEDD Series card fiber port D/D information: Rx Sensitivity
1.3.6.1.4.1.4756.20.441.20.1.129ColumneddFx1DDTxPWRRemoteAread-onlycurrentEDD Series card fiber port D/D information: Tx power
1.3.6.1.4.1.4756.20.441.20.1.130ColumneddFx1DDRxPWRRemoteAread-onlycurrentEDD Series card fiber port D/D information: Rx power
1.3.6.1.4.1.4756.20.441.20.1.131ColumneddFx1DDTempRemoteAread-onlycurrentEDD Series card fiber port D/D information: Temperature in degree C
1.3.6.1.4.1.4756.20.441.20.1.132ColumneddFx1DDPWRMarginRemoteAread-onlycurrentEDD Series card fiber port D/D information: Power margin
1.3.6.1.4.1.4756.20.441.20.1.133ColumneddFx1DDPWRLossRemoteAread-onlycurrentEDD Series card fiber port D/D information: Power loss
1.3.6.1.4.1.4756.20.441.20.1.134ColumneddFx2DDRemoteAread-onlycurrentEDD Series card fiber2 Digital Diagnostic function: 0:NO 1:Yes
1.3.6.1.4.1.4756.20.441.20.1.135ColumneddFx2DDVendorRemoteAread-onlycurrentEDD Series card fiber2 D/D information: Vendor name
1.3.6.1.4.1.4756.20.441.20.1.136ColumneddFx2DDPartNoRemoteAread-onlycurrentEDD Series card fiber2 D/D information: Vendor part number
1.3.6.1.4.1.4756.20.441.20.1.137ColumneddFx2DDFiberTypeRemoteAread-onlycurrentEDD Series card fiber2 D/D information: Fiber Type
1.3.6.1.4.1.4756.20.441.20.1.138ColumneddFx2DDWaveLenRemoteAread-onlycurrentEDD Series card fiber2 D/D information: Wave length 1
1.3.6.1.4.1.4756.20.441.20.1.139ColumneddFx2DDWaveLen2RemoteAread-onlycurrentEDD Series card fiber2 D/D information: Wave length 2
1.3.6.1.4.1.4756.20.441.20.1.140ColumneddFx2DDLinkLenRemoteAread-onlycurrentEDD Series card fiber2 D/D information: Link length
1.3.6.1.4.1.4756.20.441.20.1.141ColumneddFx2DDLenUnitRemoteAread-onlycurrentEDD Series card fiber2 D/D information: Length Unit
1.3.6.1.4.1.4756.20.441.20.1.142ColumneddFx2DDStatusRemoteAread-onlycurrentEDD Series card fiber2 D/D information: Status Support
1.3.6.1.4.1.4756.20.441.20.1.143ColumneddFx2DDRxSensRemoteAread-onlycurrentEDD Series card fiber2 D/D information: Rx Sensitivity
1.3.6.1.4.1.4756.20.441.20.1.144ColumneddFx2DDTxPWRRemoteAread-onlycurrentEDD Series card fiber2 D/D information: Tx power
1.3.6.1.4.1.4756.20.441.20.1.145ColumneddFx2DDRxPWRRemoteAread-onlycurrentEDD Series card fiber2 D/D information: Rx power
1.3.6.1.4.1.4756.20.441.20.1.146ColumneddFx2DDTempRemoteAread-onlycurrentEDD Series card fiber2 D/D information: Temperature in degree C
1.3.6.1.4.1.4756.20.441.20.1.147ColumneddFx2DDPWRMarginRemoteAread-onlycurrentEDD Series card fiber2 D/D information: Power margin
1.3.6.1.4.1.4756.20.441.20.1.148ColumneddFx2DDPWRLossRemoteAread-onlycurrentEDD Series card fiber2 D/D information: Power loss
1.3.6.1.4.1.4756.20.441.20.1.149ColumneddFx3DDRemoteAread-onlycurrentEDD Series card fiber3 Digital Diagnostic function: 0:NO 1:Yes
1.3.6.1.4.1.4756.20.441.20.1.150ColumneddFx3DDVendorRemoteAread-onlycurrentEDD Series card fiber3 D/D information: Vendor name
1.3.6.1.4.1.4756.20.441.20.1.151ColumneddFx3DDPartNoRemoteAread-onlycurrentEDD Series card fiber32 D/D information: Vendor part number
1.3.6.1.4.1.4756.20.441.20.1.152ColumneddFx3DDFiberTypeRemoteAread-onlycurrentEDD Series card fiber3 D/D information: Fiber Type
1.3.6.1.4.1.4756.20.441.20.1.153ColumneddFx3DDWaveLenRemoteAread-onlycurrentEDD Series card fiber3 D/D information: Wave length 1
1.3.6.1.4.1.4756.20.441.20.1.154ColumneddFx3DDWaveLen2RemoteAread-onlycurrentEDD Series card fiber3 D/D information: Wave length 2
1.3.6.1.4.1.4756.20.441.20.1.155ColumneddFx3DDLinkLenRemoteAread-onlycurrentEDD Series card fiber3 D/D information: Link length
1.3.6.1.4.1.4756.20.441.20.1.156ColumneddFx3DDLenUnitRemoteAread-onlycurrentEDD Series card fiber3 D/D information: Length Unit
1.3.6.1.4.1.4756.20.441.20.1.157ColumneddFx3DDStatusRemoteAread-onlycurrentEDD Series card fiber3 D/D information: Status Support
1.3.6.1.4.1.4756.20.441.20.1.158ColumneddFx3DDRxSensRemoteAread-onlycurrentEDD Series card fiber3 D/D information: Rx Sensitivity
1.3.6.1.4.1.4756.20.441.20.1.159ColumneddFx3DDTxPWRRemoteAread-onlycurrentEDD Series card fiber3 D/D information: Tx power
1.3.6.1.4.1.4756.20.441.20.1.160ColumneddFx3DDRxPWRRemoteAread-onlycurrentEDD Series card fiber3 D/D information: Rx power
1.3.6.1.4.1.4756.20.441.20.1.161ColumneddFx3DDTempRemoteAread-onlycurrentEDD Series card fiber3 D/D information: Temperature in degree C
1.3.6.1.4.1.4756.20.441.20.1.162ColumneddFx3DDPWRMarginRemoteAread-onlycurrentEDD Series card fiber3 D/D information: Power margin
1.3.6.1.4.1.4756.20.441.20.1.163ColumneddFx3DDPWRLossRemoteAread-onlycurrentEDD Series card fiber3 D/D information: Power loss
1.3.6.1.4.1.4756.20.441.20.1.164ColumneddTestRemoteAread-onlycurrentEDD Series card test led sts: 0: Off 1: On
1.3.6.1.4.1.4756.20.441.20.1.165ColumneddClearPortCounterRemoteAread-writecurrentEDD Series card clear port counter: 0: Off 1: Action
1.3.6.1.4.1.4756.20.441.20.1.166ColumneddAggrSourceMACAddrRemoteAread-writecurrentEDD Series card Aggregation Mode Configuration: Source MAC Address 0: No 1: Yes
1.3.6.1.4.1.4756.20.441.20.1.167ColumneddAggrDestinationMACAddrRemoteAread-writecurrentEDD Series card Aggregation Mode Configuration: Destination MAC Address 0: No 1: Yes
1.3.6.1.4.1.4756.20.441.20.1.168ColumneddAggrIPAddrRemoteAread-writecurrentEDD Series card Aggregation Mode Configuration: IP Address 0: No 1: Yes
1.3.6.1.4.1.4756.20.441.20.1.169ColumneddAggrTCPUDPPortNumRemoteAread-writecurrentEDD Series card Aggregation Mode Configuration: TCP/UDP Port Number 0: No 1: Yes
1.3.6.1.4.1.4756.20.441.20.1.170ColumneddAggrGroupPort1ConfRemoteAread-writecurrentEDD Series card Aggregation Group Port1 Configuration: 0: Normal 1: ID1 2: ID2
1.3.6.1.4.1.4756.20.441.20.1.171ColumneddAggrGroupPort2ConfRemoteAread-writecurrentEDD Series card Aggregation Group Port2 Configuration: 0: Normal 1: ID1 2: ID2
1.3.6.1.4.1.4756.20.441.20.1.172ColumneddAggrGroupPort3ConfRemoteAread-writecurrentEDD Series card Aggregation Group Port3 Configuration: 0: Normal 1: ID1 2: ID2
1.3.6.1.4.1.4756.20.441.20.1.173ColumneddAggrGroupPort4ConfRemoteAread-writecurrentEDD Series card Aggregation Group Port4 Configuration: 0: Normal 1: ID1 2: ID2
1.3.6.1.4.1.4756.20.441.20.1.174ColumneddPort1LACPEnabledRemoteAread-writecurrentEDD Series card Port1 LACP Enabled: 0: No 1: Yes
1.3.6.1.4.1.4756.20.441.20.1.175ColumneddPort1LACPKEYRemoteAread-writecurrentEDD Series card Port1 LACP Key value: The Key value incurred by the port, range 0-65535.The value of 0 means auto.
1.3.6.1.4.1.4756.20.441.20.1.176ColumneddPort1LACPRoleRemoteAread-writecurrentEDD Series card Port1 LACP Role: 0: Passive 1: Active
1.3.6.1.4.1.4756.20.441.20.1.177ColumneddPort1LACPTimeOutRemoteAread-writecurrentEDD Series card Port1 LACP Time out: 0: Slow 1: Fast
1.3.6.1.4.1.4756.20.441.20.1.178ColumneddPort1LACPPrioRemoteAread-writecurrentEDD Series card Port1 LACP priority: The Key value incurred by the port, range 1-65535.
1.3.6.1.4.1.4756.20.441.20.1.179ColumneddPort2LACPEnabledRemoteAread-writecurrentEDD Series card Port2 LACP Enabled: 0: No 1: Yes
1.3.6.1.4.1.4756.20.441.20.1.180ColumneddPort2LACPKEYRemoteAread-writecurrentEDD Series card Port2 LACP Key value: The Key value incurred by the port, range 0-65535.The value of 0 means auto.
1.3.6.1.4.1.4756.20.441.20.1.181ColumneddPort2LACPRoleRemoteAread-writecurrentEDD Series card Port2 LACP Role: 0: Passive 1: Active
1.3.6.1.4.1.4756.20.441.20.1.182ColumneddPort2LACPTimeOutRemoteAread-writecurrentEDD Series card Port2 LACP Time out: 0: Slow 1: Fast
1.3.6.1.4.1.4756.20.441.20.1.183ColumneddPort2LACPPrioRemoteAread-writecurrentEDD Series card Port2 LACP priority: The Key value incurred by the port, range 1-65535.
1.3.6.1.4.1.4756.20.441.20.1.184ColumneddPort3LACPEnabledRemoteAread-writecurrentEDD Series card Port3 LACP Enabled: 0: No 1: Yes
1.3.6.1.4.1.4756.20.441.20.1.185ColumneddPort3LACPKEYRemoteAread-writecurrentEDD Series card Port3 LACP Key value: The Key value incurred by the port, range 0-65535.The value of 0 means auto.
1.3.6.1.4.1.4756.20.441.20.1.186ColumneddPort3LACPRoleRemoteAread-writecurrentEDD Series card Port3 LACP Role: 0: Passive 1: Active
1.3.6.1.4.1.4756.20.441.20.1.187ColumneddPort3LACPTimeOutRemoteAread-writecurrentEDD Series card Port3 LACP Time out: 0: Slow 1: Fast
1.3.6.1.4.1.4756.20.441.20.1.188ColumneddPort3LACPPrioRemoteAread-writecurrentEDD Series card Port3 LACP priority: The Key value incurred by the port, range 1-65535.
1.3.6.1.4.1.4756.20.441.20.1.189ColumneddPort4LACPEnabledRemoteAread-writecurrentEDD Series card Port4 LACP Enabled: 0: No 1: Yes
1.3.6.1.4.1.4756.20.441.20.1.190ColumneddPort4LACPKEYRemoteAread-writecurrentEDD Series card Port4 LACP Key value: The Key value incurred by the port, range 0-65535.The value of 0 means auto.
1.3.6.1.4.1.4756.20.441.20.1.191ColumneddPort4LACPRoleRemoteAread-writecurrentEDD Series card Port4 LACP Role: 0: Passive 1: Active
1.3.6.1.4.1.4756.20.441.20.1.192ColumneddPort4LACPTimeOutRemoteAread-writecurrentEDD Series card Port4 LACP Time out: 0: Slow 1: Fast
1.3.6.1.4.1.4756.20.441.20.1.193ColumneddPort4LACPPrioRemoteAread-writecurrentEDD Series card Port4 LACP priority: The Key value incurred by the port, range 1-65535.
1.3.6.1.4.1.4756.20.441.20.1.194ColumneddPort1LACPstsRemoteAread-onlycurrentEDD Series card Port1 LACP status: 0: No 1: Yes 2: Standby
1.3.6.1.4.1.4756.20.441.20.1.195ColumneddPort1LACPKEYstsRemoteAread-onlycurrentEDD Series card Port1 LACP status: Key
1.3.6.1.4.1.4756.20.441.20.1.196ColumneddPort1LACPAggrIDstsRemoteAread-onlycurrentEDD Series card Port1 LACP status: Aggr ID
1.3.6.1.4.1.4756.20.441.20.1.197ColumneddPort1LACPParnterSysIDstsRemoteAread-onlycurrentEDD Series card Port1 LACP status: Parnter System ID
1.3.6.1.4.1.4756.20.441.20.1.198ColumneddPort1LACPParnterPortstsRemoteAread-onlycurrentEDD Series card Port1 LACP status: Parnter Port Status
1.3.6.1.4.1.4756.20.441.20.1.199ColumneddPort1LACPParnterProistsRemoteAread-onlycurrentEDD Series card Port1 LACP status: Parnter Priority
1.3.6.1.4.1.4756.20.441.20.1.200ColumneddPort2LACPstsRemoteAread-onlycurrentEDD Series card Port2 LACP status: 0: No 1: Yes 2: Standby
1.3.6.1.4.1.4756.20.441.20.1.201ColumneddPort2LACPKEYstsRemoteAread-onlycurrentEDD Series card Port2 LACP status: Key
1.3.6.1.4.1.4756.20.441.20.1.202ColumneddPort2LACPAggrIDstsRemoteAread-onlycurrentEDD Series card Port2 LACP status: Aggr ID
1.3.6.1.4.1.4756.20.441.20.1.203ColumneddPort2LACPParnterSysIDstsRemoteAread-onlycurrentEDD Series card Port2 LACP status: Parnter System ID
1.3.6.1.4.1.4756.20.441.20.1.204ColumneddPort2LACPParnterPortstsRemoteAread-onlycurrentEDD Series card Port2 LACP status: Parnter Port Status
1.3.6.1.4.1.4756.20.441.20.1.205ColumneddPort2LACPParnterProistsRemoteAread-onlycurrentEDD Series card Port2 LACP status: Parnter Priority
1.3.6.1.4.1.4756.20.441.20.1.206ColumneddPort3LACPstsRemoteAread-onlycurrentEDD Series card Port3 LACP status: 0: No 1: Yes 2: Standby
1.3.6.1.4.1.4756.20.441.20.1.207ColumneddPort3LACPKEYstsRemoteAread-onlycurrentEDD Series card Port3 LACP status: Key
1.3.6.1.4.1.4756.20.441.20.1.208ColumneddPort3LACPAggrIDstsRemoteAread-onlycurrentEDD Series card Port3 LACP status: Aggr ID
1.3.6.1.4.1.4756.20.441.20.1.209ColumneddPort3LACPParnterSysIDstsRemoteAread-onlycurrentEDD Series card Port3 LACP status: Parnter System ID
1.3.6.1.4.1.4756.20.441.20.1.210ColumneddPort3LACPParnterPortstsRemoteAread-onlycurrentEDD Series card Port3 LACP status: Parnter Port Status
1.3.6.1.4.1.4756.20.441.20.1.211ColumneddPort3LACPParnterProistsRemoteAread-onlycurrentEDD Series card Port3 LACP status: Parnter Priority
1.3.6.1.4.1.4756.20.441.20.1.212ColumneddPort4LACPstsRemoteAread-onlycurrentEDD Series card Port4 LACP status: 0: No 1: Yes 2: Standby
1.3.6.1.4.1.4756.20.441.20.1.213ColumneddPort4LACPKEYstsRemoteAread-onlycurrentEDD Series card Port4 LACP status: Key
1.3.6.1.4.1.4756.20.441.20.1.214ColumneddPort4LACPAggrIDstsRemoteAread-onlycurrentEDD Series card Port4 LACP status: Aggr ID
1.3.6.1.4.1.4756.20.441.20.1.215ColumneddPort4LACPParnterSysIDstsRemoteAread-onlycurrentEDD Series card Port4 LACP status: Parnter System ID
1.3.6.1.4.1.4756.20.441.20.1.216ColumneddPort4LACPParnterPortstsRemoteAread-onlycurrentEDD Series card Port4 LACP status: Parnter Port Status
1.3.6.1.4.1.4756.20.441.20.1.217ColumneddPort4LACPParnterProistsRemoteAread-onlycurrentEDD Series card Port4 LACP status: Parnter Priority
1.3.6.1.4.1.4756.20.441.20.1.218ColumneddOAMPort1EnableRemoteAread-writecurrentEDD Series card Port1 OAM: 0: Off 1: On
1.3.6.1.4.1.4756.20.441.20.1.219ColumneddOAMPort1ModeRemoteAread-writecurrentEDD Series card Port1 OAM: 0: Passive 1: Active
1.3.6.1.4.1.4756.20.441.20.1.220ColumneddOAMPort1LoopBackRemoteAread-writecurrentEDD Series card Port1 OAM LoopBack: 0: Off 1: On
1.3.6.1.4.1.4756.20.441.20.1.221ColumneddOAMPort1LinkMonitorRemoteAread-writecurrentEDD Series card Port1 OAM Link Monitor: 0: Off 1: On
1.3.6.1.4.1.4756.20.441.20.1.222ColumneddOAMPort1MIBRetrievalRemoteAread-writecurrentEDD Series card Port1 OAM MIB Retrieval: 0: Off 1: On
1.3.6.1.4.1.4756.20.441.20.1.223ColumneddOAMPort1LoopBackOPRemoteAread-onlycurrentEDD Series card Port1 OAM LoopBack operation: 0: Off 1: On
1.3.6.1.4.1.4756.20.441.20.1.224ColumneddOAMPort2EnableRemoteAread-writecurrentEDD Series card Port2 OAM: 0: Off 1: On
1.3.6.1.4.1.4756.20.441.20.1.225ColumneddOAMPort2ModeRemoteAread-writecurrentEDD Series card Port2 OAM: 0: Passive 1: Active
1.3.6.1.4.1.4756.20.441.20.1.226ColumneddOAMPort2LoopBackRemoteAread-writecurrentEDD Series card Port2 OAM LoopBack: 0: Off 1: On
1.3.6.1.4.1.4756.20.441.20.1.227ColumneddOAMPort2LinkMonitorRemoteAread-writecurrentEDD Series card Port2 OAM Link Monitor: 0: Off 1: On
1.3.6.1.4.1.4756.20.441.20.1.228ColumneddOAMPort2MIBRetrievalRemoteAread-writecurrentEDD Series card Port2 OAM MIB Retrieval: 0: Off 1: On
1.3.6.1.4.1.4756.20.441.20.1.229ColumneddOAMPort2LoopBackOPRemoteAread-onlycurrentEDD Series card Port2 OAM LoopBack operation: 0: Off 1: On
1.3.6.1.4.1.4756.20.441.20.1.230ColumneddOAMPort3EnableRemoteAread-writecurrentEDD Series card Port3 OAM: 0: Off 1: On
1.3.6.1.4.1.4756.20.441.20.1.231ColumneddOAMPort3ModeRemoteAread-writecurrentEDD Series card Port3 OAM: 0: Passive 1: Active
1.3.6.1.4.1.4756.20.441.20.1.232ColumneddOAMPort3LoopBackRemoteAread-writecurrentEDD Series card Port3 OAM: 0: Off 1: On
1.3.6.1.4.1.4756.20.441.20.1.233ColumneddOAMPort3LinkMonitorRemoteAread-writecurrentEDD Series card Port3 OAM Link Monitor: 0: Off 1: On
1.3.6.1.4.1.4756.20.441.20.1.234ColumneddOAMPort3MIBRetrievalRemoteAread-writecurrentEDD Series card Port3 OAM MIB Retrieval: 0: Off 1: On
1.3.6.1.4.1.4756.20.441.20.1.235ColumneddOAMPort3LoopBackOPRemoteAread-onlycurrentEDD Series card Port3 OAM LoopBack operation: 0: Disable 1: Enable
1.3.6.1.4.1.4756.20.441.20.1.236ColumneddOAMPort4EnableRemoteAread-writecurrentEDD Series card Port4 OAM: 0: Off 1: On
1.3.6.1.4.1.4756.20.441.20.1.237ColumneddOAMPort4ModeRemoteAread-writecurrentEDD Series card Port4 OAM: 0: Passive 1: Active
1.3.6.1.4.1.4756.20.441.20.1.238ColumneddOAMPort4LoopBackRemoteAread-writecurrentEDD Series card Port4 OAM: 0: Off 1: On
1.3.6.1.4.1.4756.20.441.20.1.239ColumneddOAMPort4LinkMonitorRemoteAread-writecurrentEDD Series card Port4 OAM Link Monitor: 0: Off 1: On
1.3.6.1.4.1.4756.20.441.20.1.240ColumneddOAMPort4MIBRetrievalRemoteAread-writecurrentEDD Series card Port4 OAM MIB Retrieval: 0: Off 1: On
1.3.6.1.4.1.4756.20.441.20.1.241ColumneddOAMPort4LoopBackOPRemoteAread-onlycurrentEDD Series card Port4 OAM LoopBack operation: 0: On 1: Off
1.3.6.1.4.1.4756.20.441.20.1.242ColumneddPort1EFEErrorWindowRemoteAread-writecurrentEDD Series card Port1 Link Event Configuration: Error Frame Event - Error Window
1.3.6.1.4.1.4756.20.441.20.1.243ColumneddPort1EFEErrorThresholdRemoteAread-writecurrentEDD Series card Port1 Link Event Configuration: Error Frame Event - Error Threshold
1.3.6.1.4.1.4756.20.441.20.1.244ColumneddPort1SPEEErrorWindowRemoteAread-writecurrentEDD Series card Port1 Link Event Configuration: Symbol Period Error Event - Error Window
1.3.6.1.4.1.4756.20.441.20.1.245ColumneddPort1SPEEErrorThresholdRemoteAread-writecurrentEDD Series card Port1 Link Event Configuration: Symbol Period Error Event - Error Threshold
1.3.6.1.4.1.4756.20.441.20.1.246ColumneddPort1SSEErrorWindowRemoteAread-writecurrentEDD Series card Port1 Link Event Configuration: Seconds Summary Event - Error Window
1.3.6.1.4.1.4756.20.441.20.1.247ColumneddPort1SSEErrorThresholdRemoteAread-writecurrentEDD Series card Port1 Link Event Configuration: Seconds Summary Event - Error Threshold
1.3.6.1.4.1.4756.20.441.20.1.248ColumneddPort2EFEErrorWindowRemoteAread-writecurrentEDD Series card Port2 Link Event Configuration: Error Frame Event - Error Window
1.3.6.1.4.1.4756.20.441.20.1.249ColumneddPort2EFEErrorThresholdRemoteAread-writecurrentEDD Series card Port2 Link Event Configuration: Error Frame Event - Error Threshold
1.3.6.1.4.1.4756.20.441.20.1.250ColumneddPort2SPEEErrorWindowRemoteAread-writecurrentEDD Series card Port2 Link Event Configuration: Symbol Period Error Event - Error Window
1.3.6.1.4.1.4756.20.441.20.1.251ColumneddPort2SPEEErrorThresholdRemoteAread-writecurrentEDD Series card Port2 Link Event Configuration: Symbol Period Error Event - Error Threshold
1.3.6.1.4.1.4756.20.441.20.1.252ColumneddPort2SSEErrorWindowRemoteAread-writecurrentEDD Series card Port2 Link Event Configuration: Seconds Summary Event - Error Window
1.3.6.1.4.1.4756.20.441.20.1.253ColumneddPort2SSEErrorThresholdRemoteAread-writecurrentEDD Series card Port2 Link Event Configuration: Seconds Summary Event - Error Threshold
1.3.6.1.4.1.4756.20.441.20.1.254ColumneddPort3EFEErrorWindowRemoteAread-writecurrentEDD Series card Port3 Link Event Configuration: Error Frame Event - Error Window
1.3.6.1.4.1.4756.20.441.20.1.255ColumneddPort3EFEErrorThresholdRemoteAread-writecurrentEDD Series card Port3 Link Event Configuration: Error Frame Event - Error Threshold
1.3.6.1.4.1.4756.20.441.20.1.256ColumneddPort3SPEEErrorWindowRemoteAread-writecurrentEDD Series card Port3 Link Event Configuration: Symbol Period Error Event - Error Window
1.3.6.1.4.1.4756.20.441.20.1.257ColumneddPort3SPEEErrorThresholdRemoteAread-writecurrentEDD Series card Port3 Link Event Configuration: Symbol Period Error Event - Error Threshold
1.3.6.1.4.1.4756.20.441.20.1.258ColumneddPort3SSEErrorWindowRemoteAread-writecurrentEDD Series card Port3 Link Event Configuration: Seconds Summary Event - Error Window
1.3.6.1.4.1.4756.20.441.20.1.259ColumneddPort3SSEErrorThresholdRemoteAread-writecurrentEDD Series card Port3 Link Event Configuration: Seconds Summary Event - Error Threshold
1.3.6.1.4.1.4756.20.441.20.1.260ColumneddPort4EFEErrorWindowRemoteAread-writecurrentEDD Series card Port4 Link Event Configuration: Error Frame Event - Error Window
1.3.6.1.4.1.4756.20.441.20.1.261ColumneddPort4EFEErrorThresholdRemoteAread-writecurrentEDD Series card Port4 Link Event Configuration: Error Frame Event - Error Threshold
1.3.6.1.4.1.4756.20.441.20.1.262ColumneddPort4SPEEErrorWindowRemoteAread-writecurrentEDD Series card Port4 Link Event Configuration: Symbol Period Error Event - Error Window
1.3.6.1.4.1.4756.20.441.20.1.263ColumneddPort4SPEEErrorThresholdRemoteAread-writecurrentEDD Series card Port4 Link Event Configuration: Symbol Period Error Event - Error Threshold
1.3.6.1.4.1.4756.20.441.20.1.264ColumneddPort4SSEErrorWindowRemoteAread-writecurrentEDD Series card Port4 Link Event Configuration: Seconds Summary Event - Error Window
1.3.6.1.4.1.4756.20.441.20.1.265ColumneddPort4SSEErrorThresholdRemoteAread-writecurrentEDD Series card Port4 Link Event Configuration: Seconds Summary Event - Error Threshold
1.3.6.1.4.1.4756.20.441.20.1.266ColumneddPort1RxOAMInfoPDURemoteAread-onlycurrentEDD Series card Port1 Detailed Link OAM Statistics: Rx OAM Information PDU's
1.3.6.1.4.1.4756.20.441.20.1.267ColumneddPort1RxUniqueErrorEventRemoteAread-onlycurrentEDD Series card Port1 Detailed Link OAM Statistics: Rx Unique Error Event Notificatio
1.3.6.1.4.1.4756.20.441.20.1.268ColumneddPort1RxDuplicateErrorEventRemoteAread-onlycurrentEDD Series card Port1 Detailed Link OAM Statistics: Rx Duplicate Error Event Notification
1.3.6.1.4.1.4756.20.441.20.1.269ColumneddPort1RxLoopBackControlRemoteAread-onlycurrentEDD Series card Port1 Detailed Link OAM Statistics: Rx Loopback Control
1.3.6.1.4.1.4756.20.441.20.1.270ColumneddPort1RxVariableRequestRemoteAread-onlycurrentEDD Series card Port1 Detailed Link OAM Statistics: Rx Variable Request
1.3.6.1.4.1.4756.20.441.20.1.271ColumneddPort1RxVariableResponseRemoteAread-onlycurrentEDD Series card Port1 Detailed Link OAM Statistics: Rx Variable Response
1.3.6.1.4.1.4756.20.441.20.1.272ColumneddPort1RxOrgSpecificPDURemoteAread-onlycurrentEDD Series card Port1 Detailed Link OAM Statistics: Rx Org Specific PDU's
1.3.6.1.4.1.4756.20.441.20.1.273ColumneddPort1RxUnsupportedCodesRemoteAread-onlycurrentEDD Series card Port1 Detailed Link OAM Statistics: Rx Unsupported Codes
1.3.6.1.4.1.4756.20.441.20.1.274ColumneddPort1RxLinkFaultPDURemoteAread-onlycurrentEDD Series card Port1 Detailed Link OAM Statistics: Rx Link Fault PDU's
1.3.6.1.4.1.4756.20.441.20.1.275ColumneddPort1RxDyingGaspRemoteAread-onlycurrentEDD Series card Port1 Detailed Link OAM Statistics: Rx Dying Gasp
1.3.6.1.4.1.4756.20.441.20.1.276ColumneddPort1RxCriticalEventPDURemoteAread-onlycurrentEDD Series card Port1 Detailed Link OAM Statistics: Rx Dying Gasp
1.3.6.1.4.1.4756.20.441.20.1.277ColumneddPort1TxOAMInfoPDURemoteAread-onlycurrentEDD Series card Port1 Detailed Link OAM Statistics: Tx OAM Information PDU's
1.3.6.1.4.1.4756.20.441.20.1.278ColumneddPort1TxUniqueErrorEventRemoteAread-onlycurrentEDD Series card Port1 Detailed Link OAM Statistics: Tx Unique Error Event Notificatio
1.3.6.1.4.1.4756.20.441.20.1.279ColumneddPort1TxDuplicateErrorEventRemoteAread-onlycurrentEDD Series card Port1 Detailed Link OAM Statistics: Tx Duplicate Error Event Notification
1.3.6.1.4.1.4756.20.441.20.1.280ColumneddPort1TxLoopBackControlRemoteAread-onlycurrentEDD Series card Port1 Detailed Link OAM Statistics: Tx Loopback Control
1.3.6.1.4.1.4756.20.441.20.1.281ColumneddPort1TxVariableRequestRemoteAread-onlycurrentEDD Series card Port1 Detailed Link OAM Statistics: Tx Variable Request
1.3.6.1.4.1.4756.20.441.20.1.282ColumneddPort1TxVariableResponseRemoteAread-onlycurrentEDD Series card Port1 Detailed Link OAM Statistics: Tx Variable Response
1.3.6.1.4.1.4756.20.441.20.1.283ColumneddPort1TxOrgSpecificPDURemoteAread-onlycurrentEDD Series card Port1 Detailed Link OAM Statistics: Tx Org Specific PDU's
1.3.6.1.4.1.4756.20.441.20.1.284ColumneddPort1TxUnsupportedCodesRemoteAread-onlycurrentEDD Series card Port1 Detailed Link OAM Statistics: Tx Unsupported Codes
1.3.6.1.4.1.4756.20.441.20.1.285ColumneddPort1TxLinkFaultPDURemoteAread-onlycurrentEDD Series card Port1 Detailed Link OAM Statistics: Tx Link Fault PDU's
1.3.6.1.4.1.4756.20.441.20.1.286ColumneddPort1TxDyingGaspRemoteAread-onlycurrentEDD Series card Port1 Detailed Link OAM Statistics: Tx Dying Gasp
1.3.6.1.4.1.4756.20.441.20.1.287ColumneddPort1TxCriticalEventPDURemoteAread-onlycurrentEDD Series card Port1 Detailed Link OAM Statistics: Tx Dying Gasp
1.3.6.1.4.1.4756.20.441.20.1.288ColumneddPort2RxOAMInfoPDURemoteAread-onlycurrentEDD Series card Port2 Detailed Link OAM Statistics: Rx OAM Information PDU's
1.3.6.1.4.1.4756.20.441.20.1.289ColumneddPort2RxUniqueErrorEventRemoteAread-onlycurrentEDD Series card Port2 Detailed Link OAM Statistics: Rx Unique Error Event Notificatio
1.3.6.1.4.1.4756.20.441.20.1.290ColumneddPort2RxDuplicateErrorEventRemoteAread-onlycurrentEDD Series card Port2 Detailed Link OAM Statistics: Rx Duplicate Error Event Notification
1.3.6.1.4.1.4756.20.441.20.1.291ColumneddPort2RxLoopBackControlRemoteAread-onlycurrentEDD Series card Port2 Detailed Link OAM Statistics: Rx Loopback Control
1.3.6.1.4.1.4756.20.441.20.1.292ColumneddPort2RxVariableRequestRemoteAread-onlycurrentEDD Series card Port2 Detailed Link OAM Statistics: Rx Variable Request
1.3.6.1.4.1.4756.20.441.20.1.293ColumneddPort2RxVariableResponseRemoteAread-onlycurrentEDD Series card Port2 Detailed Link OAM Statistics: Rx Variable Response
1.3.6.1.4.1.4756.20.441.20.1.294ColumneddPort2RxOrgSpecificPDURemoteAread-onlycurrentEDD Series card Port2 Detailed Link OAM Statistics: Rx Org Specific PDU's
1.3.6.1.4.1.4756.20.441.20.1.295ColumneddPort2RxUnsupportedCodesRemoteAread-onlycurrentEDD Series card Port2 Detailed Link OAM Statistics: Rx Unsupported Codes
1.3.6.1.4.1.4756.20.441.20.1.296ColumneddPort2RxLinkFaultPDURemoteAread-onlycurrentEDD Series card Port2 Detailed Link OAM Statistics: Rx Link Fault PDU's
1.3.6.1.4.1.4756.20.441.20.1.297ColumneddPort2RxDyingGaspRemoteAread-onlycurrentEDD Series card Port2 Detailed Link OAM Statistics: Rx Dying Gasp
1.3.6.1.4.1.4756.20.441.20.1.298ColumneddPort2RxCriticalEventPDURemoteAread-onlycurrentEDD Series card Port2 Detailed Link OAM Statistics: Rx Dying Gasp
1.3.6.1.4.1.4756.20.441.20.1.299ColumneddPort2TxOAMInfoPDURemoteAread-onlycurrentEDD Series card Port2 Detailed Link OAM Statistics: Tx OAM Information PDU's
1.3.6.1.4.1.4756.20.441.20.1.300ColumneddPort2TxUniqueErrorEventRemoteAread-onlycurrentEDD Series card Port2 Detailed Link OAM Statistics: Tx Unique Error Event Notificatio
1.3.6.1.4.1.4756.20.441.20.1.301ColumneddPort2TxDuplicateErrorEventRemoteAread-onlycurrentEDD Series card Port2 Detailed Link OAM Statistics: Tx Duplicate Error Event Notification
1.3.6.1.4.1.4756.20.441.20.1.302ColumneddPort2TxLoopBackControlRemoteAread-onlycurrentEDD Series card Port2 Detailed Link OAM Statistics: Tx Loopback Control
1.3.6.1.4.1.4756.20.441.20.1.303ColumneddPort2TxVariableRequestRemoteAread-onlycurrentEDD Series card Port2 Detailed Link OAM Statistics: Tx Variable Request
1.3.6.1.4.1.4756.20.441.20.1.304ColumneddPort2TxVariableResponseRemoteAread-onlycurrentEDD Series card Port2 Detailed Link OAM Statistics: Tx Variable Response
1.3.6.1.4.1.4756.20.441.20.1.305ColumneddPort2TxOrgSpecificPDURemoteAread-onlycurrentEDD Series card Port2 Detailed Link OAM Statistics: Tx Org Specific PDU's
1.3.6.1.4.1.4756.20.441.20.1.306ColumneddPort2TxUnsupportedCodesRemoteAread-onlycurrentEDD Series card Port2 Detailed Link OAM Statistics: Tx Unsupported Codes
1.3.6.1.4.1.4756.20.441.20.1.307ColumneddPort2TxLinkFaultPDURemoteAread-onlycurrentEDD Series card Port2 Detailed Link OAM Statistics: Tx Link Fault PDU's
1.3.6.1.4.1.4756.20.441.20.1.308ColumneddPort2TxDyingGaspRemoteAread-onlycurrentEDD Series card Port2 Detailed Link OAM Statistics: Tx Dying Gasp
1.3.6.1.4.1.4756.20.441.20.1.309ColumneddPort2TxCriticalEventPDURemoteAread-onlycurrentEDD Series card Port2 Detailed Link OAM Statistics: Tx Dying Gasp
1.3.6.1.4.1.4756.20.441.20.1.310ColumneddPort3RxOAMInfoPDURemoteAread-onlycurrentEDD Series card Port3 Detailed Link OAM Statistics: Rx OAM Information PDU's
1.3.6.1.4.1.4756.20.441.20.1.311ColumneddPort3RxUniqueErrorEventRemoteAread-onlycurrentEDD Series card Port3 Detailed Link OAM Statistics: Rx Unique Error Event Notificatio
1.3.6.1.4.1.4756.20.441.20.1.312ColumneddPort3RxDuplicateErrorEventRemoteAread-onlycurrentEDD Series card Port3 Detailed Link OAM Statistics: Rx Duplicate Error Event Notification
1.3.6.1.4.1.4756.20.441.20.1.313ColumneddPort3RxLoopBackControlRemoteAread-onlycurrentEDD Series card Port3 Detailed Link OAM Statistics: Rx Loopback Control
1.3.6.1.4.1.4756.20.441.20.1.314ColumneddPort3RxVariableRequestRemoteAread-onlycurrentEDD Series card Port3 Detailed Link OAM Statistics: Rx Variable Request
1.3.6.1.4.1.4756.20.441.20.1.315ColumneddPort3RxVariableResponseRemoteAread-onlycurrentEDD Series card Port3 Detailed Link OAM Statistics: Rx Variable Response
1.3.6.1.4.1.4756.20.441.20.1.316ColumneddPort3RxOrgSpecificPDURemoteAread-onlycurrentEDD Series card Port3 Detailed Link OAM Statistics: Rx Org Specific PDU's
1.3.6.1.4.1.4756.20.441.20.1.317ColumneddPort3RxUnsupportedCodesRemoteAread-onlycurrentEDD Series card Port3 Detailed Link OAM Statistics: Rx Unsupported Codes
1.3.6.1.4.1.4756.20.441.20.1.318ColumneddPort3RxLinkFaultPDURemoteAread-onlycurrentEDD Series card Port3 Detailed Link OAM Statistics: Rx Link Fault PDU's
1.3.6.1.4.1.4756.20.441.20.1.319ColumneddPort3RxDyingGaspRemoteAread-onlycurrentEDD Series card Port3 Detailed Link OAM Statistics: Rx Dying Gasp
1.3.6.1.4.1.4756.20.441.20.1.320ColumneddPort3RxCriticalEventPDURemoteAread-onlycurrentEDD Series card Port3 Detailed Link OAM Statistics: Rx Dying Gasp
1.3.6.1.4.1.4756.20.441.20.1.321ColumneddPort3TxOAMInfoPDURemoteAread-onlycurrentEDD Series card Port3 Detailed Link OAM Statistics: Tx OAM Information PDU's
1.3.6.1.4.1.4756.20.441.20.1.322ColumneddPort3TxUniqueErrorEventRemoteAread-onlycurrentEDD Series card Port3 Detailed Link OAM Statistics: Tx Unique Error Event Notificatio
1.3.6.1.4.1.4756.20.441.20.1.323ColumneddPort3TxDuplicateErrorEventRemoteAread-onlycurrentEDD Series card Port3 Detailed Link OAM Statistics: Tx Duplicate Error Event Notification
1.3.6.1.4.1.4756.20.441.20.1.324ColumneddPort3TxLoopBackControlRemoteAread-onlycurrentEDD Series card Port3 Detailed Link OAM Statistics: Tx Loopback Control
1.3.6.1.4.1.4756.20.441.20.1.325ColumneddPort3TxVariableRequestRemoteAread-onlycurrentEDD Series card Port3 Detailed Link OAM Statistics: Tx Variable Request
1.3.6.1.4.1.4756.20.441.20.1.326ColumneddPort3TxVariableResponseRemoteAread-onlycurrentEDD Series card Port3 Detailed Link OAM Statistics: Tx Variable Response
1.3.6.1.4.1.4756.20.441.20.1.327ColumneddPort3TxOrgSpecificPDURemoteAread-onlycurrentEDD Series card Port3 Detailed Link OAM Statistics: Tx Org Specific PDU's
1.3.6.1.4.1.4756.20.441.20.1.328ColumneddPort3TxUnsupportedCodesRemoteAread-onlycurrentEDD Series card Port3 Detailed Link OAM Statistics: Tx Unsupported Codes
1.3.6.1.4.1.4756.20.441.20.1.329ColumneddPort3TxLinkFaultPDURemoteAread-onlycurrentEDD Series card Port3 Detailed Link OAM Statistics: Tx Link Fault PDU's
1.3.6.1.4.1.4756.20.441.20.1.330ColumneddPort3TxDyingGaspRemoteAread-onlycurrentEDD Series card Port3 Detailed Link OAM Statistics: Tx Dying Gasp
1.3.6.1.4.1.4756.20.441.20.1.331ColumneddPort3TxCriticalEventPDURemoteAread-onlycurrentEDD Series card Port3 Detailed Link OAM Statistics: Tx Dying Gasp
1.3.6.1.4.1.4756.20.441.20.1.332ColumneddPort4RxOAMInfoPDURemoteAread-onlycurrentEDD Series card Port4 Detailed Link OAM Statistics: Rx OAM Information PDU's
1.3.6.1.4.1.4756.20.441.20.1.333ColumneddPort4RxUniqueErrorEventRemoteAread-onlycurrentEDD Series card Port4 Detailed Link OAM Statistics: Rx Unique Error Event Notificatio
1.3.6.1.4.1.4756.20.441.20.1.334ColumneddPort4RxDuplicateErrorEventRemoteAread-onlycurrentEDD Series card Port4 Detailed Link OAM Statistics: Rx Duplicate Error Event Notification
1.3.6.1.4.1.4756.20.441.20.1.335ColumneddPort4RxLoopBackControlRemoteAread-onlycurrentEDD Series card Port4 Detailed Link OAM Statistics: Rx Loopback Control
1.3.6.1.4.1.4756.20.441.20.1.336ColumneddPort4RxVariableRequestRemoteAread-onlycurrentEDD Series card Port4 Detailed Link OAM Statistics: Rx Variable Request
1.3.6.1.4.1.4756.20.441.20.1.337ColumneddPort4RxVariableResponseRemoteAread-onlycurrentEDD Series card Port4 Detailed Link OAM Statistics: Rx Variable Response
1.3.6.1.4.1.4756.20.441.20.1.338ColumneddPort4RxOrgSpecificPDURemoteAread-onlycurrentEDD Series card Port4 Detailed Link OAM Statistics: Rx Org Specific PDU's
1.3.6.1.4.1.4756.20.441.20.1.339ColumneddPort4RxUnsupportedCodesRemoteAread-onlycurrentEDD Series card Port4 Detailed Link OAM Statistics: Rx Unsupported Codes
1.3.6.1.4.1.4756.20.441.20.1.340ColumneddPort4RxLinkFaultPDURemoteAread-onlycurrentEDD Series card Port4 Detailed Link OAM Statistics: Rx Link Fault PDU's
1.3.6.1.4.1.4756.20.441.20.1.341ColumneddPort4RxDyingGaspRemoteAread-onlycurrentEDD Series card Port4 Detailed Link OAM Statistics: Rx Dying Gasp
1.3.6.1.4.1.4756.20.441.20.1.342ColumneddPort4RxCriticalEventPDURemoteAread-onlycurrentEDD Series card Port4 Detailed Link OAM Statistics: Rx Dying Gasp
1.3.6.1.4.1.4756.20.441.20.1.343ColumneddPort4TxOAMInfoPDURemoteAread-onlycurrentEDD Series card Port4 Detailed Link OAM Statistics: Tx OAM Information PDU's
1.3.6.1.4.1.4756.20.441.20.1.344ColumneddPort4TxUniqueErrorEventRemoteAread-onlycurrentEDD Series card Port4 Detailed Link OAM Statistics: Tx Unique Error Event Notificatio
1.3.6.1.4.1.4756.20.441.20.1.345ColumneddPort4TxDuplicateErrorEventRemoteAread-onlycurrentEDD Series card Port4 Detailed Link OAM Statistics: Tx Duplicate Error Event Notification
1.3.6.1.4.1.4756.20.441.20.1.346ColumneddPort4TxLoopBackControlRemoteAread-onlycurrentEDD Series card Port4 Detailed Link OAM Statistics: Tx Loopback Control
1.3.6.1.4.1.4756.20.441.20.1.347ColumneddPort4TxVariableRequestRemoteAread-onlycurrentEDD Series card Port4 Detailed Link OAM Statistics: Tx Variable Request
1.3.6.1.4.1.4756.20.441.20.1.348ColumneddPort4TxVariableResponseRemoteAread-onlycurrentEDD Series card Port4 Detailed Link OAM Statistics: Tx Variable Response
1.3.6.1.4.1.4756.20.441.20.1.349ColumneddPort4TxOrgSpecificPDURemoteAread-onlycurrentEDD Series card Port4 Detailed Link OAM Statistics: Tx Org Specific PDU's
1.3.6.1.4.1.4756.20.441.20.1.350ColumneddPort4TxUnsupportedCodesRemoteAread-onlycurrentEDD Series card Port4 Detailed Link OAM Statistics: Tx Unsupported Codes
1.3.6.1.4.1.4756.20.441.20.1.351ColumneddPort4TxLinkFaultPDURemoteAread-onlycurrentEDD Series card Port4 Detailed Link OAM Statistics: Tx Link Fault PDU's
1.3.6.1.4.1.4756.20.441.20.1.352ColumneddPort4TxDyingGaspRemoteAread-onlycurrentEDD Series card Port4 Detailed Link OAM Statistics: Tx Dying Gasp
1.3.6.1.4.1.4756.20.441.20.1.353ColumneddPort4TxCriticalEventPDURemoteAread-onlycurrentEDD Series card Port4 Detailed Link OAM Statistics: Tx Dying Gasp
1.3.6.1.4.1.4756.20.441.20.1.354ColumneddPort1PDUPermisionRemoteAread-onlycurrentEDD Series card Detailed Link OAM Status for Port 1: PDU Permission
1.3.6.1.4.1.4756.20.441.20.1.355ColumneddPort1DiscoveryStateRemoteAread-onlycurrentEDD Series card Detailed Link OAM Status for Port 1: Discovery State
1.3.6.1.4.1.4756.20.441.20.1.356ColumneddPort1PeerMACAddrRemoteAread-onlycurrentEDD Series card Detailed Link OAM Status for Port 1: Discovery State
1.3.6.1.4.1.4756.20.441.20.1.357ColumneddPort1LocalModeRemoteAread-onlycurrentEDD Series card Detailed Link OAM Status for Port 1: Local: Mode
1.3.6.1.4.1.4756.20.441.20.1.358ColumneddPort1LocalUnOperationRemoteAread-onlycurrentEDD Series card Detailed Link OAM Status for Port 1: Local: Unidirectional Operation Support
1.3.6.1.4.1.4756.20.441.20.1.359ColumneddPort1LocalRemoteLbRemoteAread-onlycurrentEDD Series card Detailed Link OAM Status for Port 1: Local: Remote Loopback Support
1.3.6.1.4.1.4756.20.441.20.1.360ColumneddPort1LocalLMRemoteAread-onlycurrentEDD Series card Detailed Link OAM Status for Port 1: RemoteA: Link Monitoring Support
1.3.6.1.4.1.4756.20.441.20.1.361ColumneddPort1LocalMIBRetrievalRemoteAread-onlycurrentEDD Series card Detailed Link OAM Status for Port 1: Local: MIB Retrieval Support
1.3.6.1.4.1.4756.20.441.20.1.362ColumneddPort1LocalMTUSizeRemoteAread-onlycurrentEDD Series card Detailed Link OAM Status for Port 1: Local: MTU Size
1.3.6.1.4.1.4756.20.441.20.1.363ColumneddPort1LocalMultiStateRemoteAread-onlycurrentEDD Series card Detailed Link OAM Status for Port 1: Local: Multiplexer State
1.3.6.1.4.1.4756.20.441.20.1.364ColumneddPort1LocalParserStateRemoteAread-onlycurrentEDD Series card Detailed Link OAM Status for Port 1: Local: Multiplexer State
1.3.6.1.4.1.4756.20.441.20.1.365ColumneddPort1LocalOUIRemoteAread-onlycurrentEDD Series card Detailed Link OAM Status for Port 1: Local: Organizational Unique Identification
1.3.6.1.4.1.4756.20.441.20.1.366ColumneddPort1LocalPDURevRemoteAread-onlycurrentEDD Series card Detailed Link OAM Status for Port 1: Local: PDU Revision
1.3.6.1.4.1.4756.20.441.20.1.367ColumneddPort1PeerModeRemoteAread-onlycurrentEDD Series card Detailed Link OAM Status for Port 1: Peer: Mode
1.3.6.1.4.1.4756.20.441.20.1.368ColumneddPort1PeerUnOperationRemoteAread-onlycurrentEDD Series card Detailed Link OAM Status for Port 1: Peer: Unidirectional Operation Support
1.3.6.1.4.1.4756.20.441.20.1.369ColumneddPort1PeerRemoteLbRemoteAread-onlycurrentEDD Series card Detailed Link OAM Status for Port 1: Peer: Remote Loopback Support
1.3.6.1.4.1.4756.20.441.20.1.370ColumneddPort1PeerLMRemoteAread-onlycurrentEDD Series card Detailed Link OAM Status for Port 1: Peer: Link Monitoring Support
1.3.6.1.4.1.4756.20.441.20.1.371ColumneddPort1PeerMIBRetrievalRemoteAread-onlycurrentEDD Series card Detailed Link OAM Status for Port 1: Peer: MIB Retrieval Support
1.3.6.1.4.1.4756.20.441.20.1.372ColumneddPort1PeerMTUSizeRemoteAread-onlycurrentEDD Series card Detailed Link OAM Status for Port 1: Peer: MTU Size
1.3.6.1.4.1.4756.20.441.20.1.373ColumneddPort1PeerMultiStateRemoteAread-onlycurrentEDD Series card Detailed Link OAM Status for Port 1: Peer: Multiplexer State
1.3.6.1.4.1.4756.20.441.20.1.374ColumneddPort1PeerParserStateRemoteAread-onlycurrentEDD Series card Detailed Link OAM Status for Port 1: Peer: Multiplexer State
1.3.6.1.4.1.4756.20.441.20.1.375ColumneddPort1PeerOUIRemoteAread-onlycurrentEDD Series card Detailed Link OAM Status for Port 1: Peer: Organizational Unique Identification
1.3.6.1.4.1.4756.20.441.20.1.376ColumneddPort1PeerPDURevRemoteAread-onlycurrentEDD Series card Detailed Link OAM Status for Port 1: Peer: PDU Revision
1.3.6.1.4.1.4756.20.441.20.1.377ColumneddPort2PDUPermisionRemoteAread-onlycurrentEDD Series card Detailed Link OAM Status for Port 2: PDU Permission
1.3.6.1.4.1.4756.20.441.20.1.378ColumneddPort2DiscoveryStateRemoteAread-onlycurrentEDD Series card Detailed Link OAM Status for Port 2: Discovery State
1.3.6.1.4.1.4756.20.441.20.1.379ColumneddPort2PeerMACAddrRemoteAread-onlycurrentEDD Series card Detailed Link OAM Status for Port 2: Discovery State
1.3.6.1.4.1.4756.20.441.20.1.380ColumneddPort2LocalModeRemoteAread-onlycurrentEDD Series card Detailed Link OAM Status for Port 2: Local: Mode
1.3.6.1.4.1.4756.20.441.20.1.381ColumneddPort2LocalUnOperationRemoteAread-onlycurrentEDD Series card Detailed Link OAM Status for Port 2: Local: Unidirectional Operation Support
1.3.6.1.4.1.4756.20.441.20.1.382ColumneddPort2LocalRemoteLbRemoteAread-onlycurrentEDD Series card Detailed Link OAM Status for Port 2: Local: Remote Loopback Support
1.3.6.1.4.1.4756.20.441.20.1.383ColumneddPort2LocalLMRemoteAread-onlycurrentEDD Series card Detailed Link OAM Status for Port 2: Local: Link Monitoring Support
1.3.6.1.4.1.4756.20.441.20.1.384ColumneddPort2LocalMIBRetrievalRemoteAread-onlycurrentEDD Series card Detailed Link OAM Status for Port 2: Local: MIB Retrieval Support
1.3.6.1.4.1.4756.20.441.20.1.385ColumneddPort2LocalMTUSizeRemoteAread-onlycurrentEDD Series card Detailed Link OAM Status for Port 2: Local: MTU Size
1.3.6.1.4.1.4756.20.441.20.1.386ColumneddPort2LocalMultiStateRemoteAread-onlycurrentEDD Series card Detailed Link OAM Status for Port 2: Local: Multiplexer State
1.3.6.1.4.1.4756.20.441.20.1.387ColumneddPort2LocalParserStateRemoteAread-onlycurrentEDD Series card Detailed Link OAM Status for Port 2: Local: Multiplexer State
1.3.6.1.4.1.4756.20.441.20.1.388ColumneddPort2LocalOUIRemoteAread-onlycurrentEDD Series card Detailed Link OAM Status for Port 2: Local: Organizational Unique Identification
1.3.6.1.4.1.4756.20.441.20.1.389ColumneddPort2LocalPDURevRemoteAread-onlycurrentEDD Series card Detailed Link OAM Status for Port 2: Local: PDU Revision
1.3.6.1.4.1.4756.20.441.20.1.390ColumneddPort2PeerModeRemoteAread-onlycurrentEDD Series card Detailed Link OAM Status for Port 2: Peer: Mode
1.3.6.1.4.1.4756.20.441.20.1.391ColumneddPort2PeerUnOperationRemoteAread-onlycurrentEDD Series card Detailed Link OAM Status for Port 2: Peer: Unidirectional Operation Support
1.3.6.1.4.1.4756.20.441.20.1.392ColumneddPort2PeerRemoteLbRemoteAread-onlycurrentEDD Series card Detailed Link OAM Status for Port 2: Peer: Remote Loopback Support
1.3.6.1.4.1.4756.20.441.20.1.393ColumneddPort2PeerLMRemoteAread-onlycurrentEDD Series card Detailed Link OAM Status for Port 2: Peer: Link Monitoring Support
1.3.6.1.4.1.4756.20.441.20.1.394ColumneddPort2PeerMIBRetrievalRemoteAread-onlycurrentEDD Series card Detailed Link OAM Status for Port 2: Peer: MIB Retrieval Support
1.3.6.1.4.1.4756.20.441.20.1.395ColumneddPort2PeerMTUSizeRemoteAread-onlycurrentEDD Series card Detailed Link OAM Status for Port 2: Peer: MTU Size
1.3.6.1.4.1.4756.20.441.20.1.396ColumneddPort2PeerMultiStateRemoteAread-onlycurrentEDD Series card Detailed Link OAM Status for Port 2: Peer: Multiplexer State
1.3.6.1.4.1.4756.20.441.20.1.397ColumneddPort2PeerParserStateRemoteAread-onlycurrentEDD Series card Detailed Link OAM Status for Port 2: Peer: Multiplexer State
1.3.6.1.4.1.4756.20.441.20.1.398ColumneddPort2PeerOUIRemoteAread-onlycurrentEDD Series card Detailed Link OAM Status for Port 2: Peer: Organizational Unique Identification
1.3.6.1.4.1.4756.20.441.20.1.399ColumneddPort2PeerPDURevRemoteAread-onlycurrentEDD Series card Detailed Link OAM Status for Port 2: Peer: PDU Revision
1.3.6.1.4.1.4756.20.441.20.1.400ColumneddPort3PDUPermisionRemoteAread-onlycurrentEDD Series card Detailed Link OAM Status for Port 3: PDU Permission
1.3.6.1.4.1.4756.20.441.20.1.401ColumneddPort3DiscoveryStateRemoteAread-onlycurrentEDD Series card Detailed Link OAM Status for Port 3: Discovery State
1.3.6.1.4.1.4756.20.441.20.1.402ColumneddPort3PeerMACAddrRemoteAread-onlycurrentEDD Series card Detailed Link OAM Status for Port 3: Discovery State
1.3.6.1.4.1.4756.20.441.20.1.403ColumneddPort3LocalModeRemoteAread-onlycurrentEDD Series card Detailed Link OAM Status for Port 3: Local: Mode
1.3.6.1.4.1.4756.20.441.20.1.404ColumneddPort3LocalUnOperationRemoteAread-onlycurrentEDD Series card Detailed Link OAM Status for Port 3: Local: Unidirectional Operation Support
1.3.6.1.4.1.4756.20.441.20.1.405ColumneddPort3LocalRemoteLbRemoteAread-onlycurrentEDD Series card Detailed Link OAM Status for Port 3: Local: Remote Loopback Support
1.3.6.1.4.1.4756.20.441.20.1.406ColumneddPort3LocalLMRemoteAread-onlycurrentEDD Series card Detailed Link OAM Status for Port 3: Local: Link Monitoring Support
1.3.6.1.4.1.4756.20.441.20.1.407ColumneddPort3LocalMIBRetrievalRemoteAread-onlycurrentEDD Series card Detailed Link OAM Status for Port 3: Local: MIB Retrieval Support
1.3.6.1.4.1.4756.20.441.20.1.408ColumneddPort3LocalMTUSizeRemoteAread-onlycurrentEDD Series card Detailed Link OAM Status for Port 3: Local: MTU Size
1.3.6.1.4.1.4756.20.441.20.1.409ColumneddPort3LocalMultiStateRemoteAread-onlycurrentEDD Series card Detailed Link OAM Status for Port 3: Local: Multiplexer State
1.3.6.1.4.1.4756.20.441.20.1.410ColumneddPort3LocalParserStateRemoteAread-onlycurrentEDD Series card Detailed Link OAM Status for Port 3: Local: Multiplexer State
1.3.6.1.4.1.4756.20.441.20.1.411ColumneddPort3LocalOUIRemoteAread-onlycurrentEDD Series card Detailed Link OAM Status for Port 3: Local: Organizational Unique Identification
1.3.6.1.4.1.4756.20.441.20.1.412ColumneddPort3LocalPDURevRemoteAread-onlycurrentEDD Series card Detailed Link OAM Status for Port 3: Local: PDU Revision
1.3.6.1.4.1.4756.20.441.20.1.413ColumneddPort3PeerModeRemoteAread-onlycurrentEDD Series card Detailed Link OAM Status for Port 3: Peer: Mode
1.3.6.1.4.1.4756.20.441.20.1.414ColumneddPort3PeerUnOperationRemoteAread-onlycurrentEDD Series card Detailed Link OAM Status for Port 3: Peer: Unidirectional Operation Support
1.3.6.1.4.1.4756.20.441.20.1.415ColumneddPort3PeerRemoteLbRemoteAread-onlycurrentEDD Series card Detailed Link OAM Status for Port 3: Peer: Remote Loopback Support
1.3.6.1.4.1.4756.20.441.20.1.416ColumneddPort3PeerLMRemoteAread-onlycurrentEDD Series card Detailed Link OAM Status for Port 3: Peer: Link Monitoring Support
1.3.6.1.4.1.4756.20.441.20.1.417ColumneddPort3PeerMIBRetrievalRemoteAread-onlycurrentEDD Series card Detailed Link OAM Status for Port 3: Peer: MIB Retrieval Support
1.3.6.1.4.1.4756.20.441.20.1.418ColumneddPort3PeerMTUSizeRemoteAread-onlycurrentEDD Series card Detailed Link OAM Status for Port 3: Peer: MTU Size
1.3.6.1.4.1.4756.20.441.20.1.419ColumneddPort3PeerMultiStateRemoteAread-onlycurrentEDD Series card Detailed Link OAM Status for Port 3: Peer: Multiplexer State
1.3.6.1.4.1.4756.20.441.20.1.420ColumneddPort3PeerParserStateRemoteAread-onlycurrentEDD Series card Detailed Link OAM Status for Port 3: Peer: Multiplexer State
1.3.6.1.4.1.4756.20.441.20.1.421ColumneddPort3PeerOUIRemoteAread-onlycurrentEDD Series card Detailed Link OAM Status for Port 3: Peer: Organizational Unique Identification
1.3.6.1.4.1.4756.20.441.20.1.422ColumneddPort3PeerPDURevRemoteAread-onlycurrentEDD Series card Detailed Link OAM Status for Port 3: Peer: PDU Revision
1.3.6.1.4.1.4756.20.441.20.1.423ColumneddPort4PDUPermisionRemoteAread-onlycurrentEDD Series card Detailed Link OAM Status for Port 4: PDU Permission
1.3.6.1.4.1.4756.20.441.20.1.424ColumneddPort4DiscoveryStateRemoteAread-onlycurrentEDD Series card Detailed Link OAM Status for Port 4: Discovery State
1.3.6.1.4.1.4756.20.441.20.1.425ColumneddPort4PeerMACAddrRemoteAread-onlycurrentEDD Series card Detailed Link OAM Status for Port 4: Discovery State
1.3.6.1.4.1.4756.20.441.20.1.426ColumneddPort4LocalModeRemoteAread-onlycurrentEDD Series card Detailed Link OAM Status for Port 4: Local: Mode
1.3.6.1.4.1.4756.20.441.20.1.427ColumneddPort4LocalUnOperationRemoteAread-onlycurrentEDD Series card Detailed Link OAM Status for Port 4: Local: Unidirectional Operation Support
1.3.6.1.4.1.4756.20.441.20.1.428ColumneddPort4LocalRemoteLbRemoteAread-onlycurrentEDD Series card Detailed Link OAM Status for Port 4: Local: Remote Loopback Support
1.3.6.1.4.1.4756.20.441.20.1.429ColumneddPort4LocalLMRemoteAread-onlycurrentEDD Series card Detailed Link OAM Status for Port 4: Local: Link Monitoring Support
1.3.6.1.4.1.4756.20.441.20.1.430ColumneddPort4LocalMIBRetrievalRemoteAread-onlycurrentEDD Series card Detailed Link OAM Status for Port 4: Local: MIB Retrieval Support
1.3.6.1.4.1.4756.20.441.20.1.431ColumneddPort4LocalMTUSizeRemoteAread-onlycurrentEDD Series card Detailed Link OAM Status for Port 4: Local: MTU Size
1.3.6.1.4.1.4756.20.441.20.1.432ColumneddPort4LocalMultiStateRemoteAread-onlycurrentEDD Series card Detailed Link OAM Status for Port 4: Local: Multiplexer State
1.3.6.1.4.1.4756.20.441.20.1.433ColumneddPort4LocalParserStateRemoteAread-onlycurrentEDD Series card Detailed Link OAM Status for Port 4: Local: Multiplexer State
1.3.6.1.4.1.4756.20.441.20.1.434ColumneddPort4LocalOUIRemoteAread-onlycurrentEDD Series card Detailed Link OAM Status for Port 4: Local: Organizational Unique Identification
1.3.6.1.4.1.4756.20.441.20.1.435ColumneddPort4LocalPDURevRemoteAread-onlycurrentEDD Series card Detailed Link OAM Status for Port 4: Local: PDU Revision
1.3.6.1.4.1.4756.20.441.20.1.436ColumneddPort4PeerModeRemoteAread-onlycurrentEDD Series card Detailed Link OAM Status for Port 4: Peer: Mode
1.3.6.1.4.1.4756.20.441.20.1.437ColumneddPort4PeerUnOperationRemoteAread-onlycurrentEDD Series card Detailed Link OAM Status for Port 4: Peer: Unidirectional Operation Support
1.3.6.1.4.1.4756.20.441.20.1.438ColumneddPort4PeerRemoteLbRemoteAread-onlycurrentEDD Series card Detailed Link OAM Status for Port 4: Peer: Remote Loopback Support
1.3.6.1.4.1.4756.20.441.20.1.439ColumneddPort4PeerLMRemoteAread-onlycurrentEDD Series card Detailed Link OAM Status for Port 4: Peer: Link Monitoring Support
1.3.6.1.4.1.4756.20.441.20.1.440ColumneddPort4PeerMIBRetrievalRemoteAread-onlycurrentEDD Series card Detailed Link OAM Status for Port 4: Peer: MIB Retrieval Support
1.3.6.1.4.1.4756.20.441.20.1.441ColumneddPort4PeerMTUSizeRemoteAread-onlycurrentEDD Series card Detailed Link OAM Status for Port 4: Peer: MTU Size
1.3.6.1.4.1.4756.20.441.20.1.442ColumneddPort4PeerMultiStateRemoteAread-onlycurrentEDD Series card Detailed Link OAM Status for Port 4: Peer: Multiplexer State
1.3.6.1.4.1.4756.20.441.20.1.443ColumneddPort4PeerParserStateRemoteAread-onlycurrentEDD Series card Detailed Link OAM Status for Port 4: Peer: Multiplexer State
1.3.6.1.4.1.4756.20.441.20.1.444ColumneddPort4PeerOUIRemoteAread-onlycurrentEDD Series card Detailed Link OAM Status for Port 4: Peer: Organizational Unique Identification
1.3.6.1.4.1.4756.20.441.20.1.445ColumneddPort4PeerPDURevRemoteAread-onlycurrentEDD Series card Detailed Link OAM Status for Port 4: Peer: PDU Revision
1.3.6.1.4.1.4756.20.441.20.1.446ColumneddCLEAROAMCOUNTERRemoteAread-writecurrentEDD Series card Clear OAM Counter: 0: Off 1: Action
1.3.6.1.4.1.4756.20.441.20.1.447ColumneddLoopProtectionEnableRemoteAread-writecurrentEDD Series card Loop Protection Configuration: General Settings - Enable Loop Protection 0: Disable 1: Enable
1.3.6.1.4.1.4756.20.441.20.1.448ColumneddLoopProtectionTxTimeRemoteAread-writecurrentEDD Series card Loop Protection Configuration: General Settings - Transmission Time
1.3.6.1.4.1.4756.20.441.20.1.449ColumneddLoopProtectionShutdownTimeRemoteAread-writecurrentEDD Series card Loop Protection Configuration: General Settings - Shutdown Time
1.3.6.1.4.1.4756.20.441.20.1.450ColumneddLoopProtectionPort1EnabledRemoteAread-writecurrentEDD Series card Loop Protection Configuration for Port 1: Port Configuration - Enable 0: Disable 1: Enable
1.3.6.1.4.1.4756.20.441.20.1.451ColumneddLoopProtectionPort1ActionRemoteAread-writecurrentEDD Series card Loop Protection Configuration for Port 1: Port Configuration - Action 0: Shutdown Port 1: Shutdown Port And Log 2: Log Only
1.3.6.1.4.1.4756.20.441.20.1.452ColumneddLoopProtectionPort1TxModeRemoteAread-writecurrentEDD Series card Loop Protection Configuration for Port 1: Port Configuration - Tx Mode 0: Disable 1: Enable
1.3.6.1.4.1.4756.20.441.20.1.453ColumneddLoopProtectionPort2EnabledRemoteAread-writecurrentEDD Series card Loop Protection Configuration for Port 2: Port Configuration - Enable 0: Disable 1: Enable
1.3.6.1.4.1.4756.20.441.20.1.454ColumneddLoopProtectionPort2ActionRemoteAread-writecurrentEDD Series card Loop Protection Configuration for Port 2: Port Configuration - Action 0: Shutdown Port 1: Shutdown Port And Log 2: Log Only
1.3.6.1.4.1.4756.20.441.20.1.455ColumneddLoopProtectionPort2TxModeRemoteAread-writecurrentEDD Series card Loop Protection Configuration for Port 2: Port Configuration - Tx Mode 0: Disable 1: Enable
1.3.6.1.4.1.4756.20.441.20.1.456ColumneddLoopProtectionPort3EnabledRemoteAread-writecurrentEDD Series card Loop Protection Configuration for Port 3: Port Configuration - Enable 0: Disable 1: Enable
1.3.6.1.4.1.4756.20.441.20.1.457ColumneddLoopProtectionPort3ActionRemoteAread-writecurrentEDD Series card Loop Protection Configuration for Port 3: Port Configuration - Action 0: Shutdown Port 1: Shutdown Port And Log 2: Log Only
1.3.6.1.4.1.4756.20.441.20.1.458ColumneddLoopProtectionPort3TxModeRemoteAread-writecurrentEDD Series card Loop Protection Configuration for Port 3: Port Configuration - Tx Mode 0: Disable 1: Enable
1.3.6.1.4.1.4756.20.441.20.1.459ColumneddLoopProtectionPort4EnabledRemoteAread-writecurrentEDD Series card Loop Protection Configuration for Port 4: Port Configuration - Enable 0: Disable 1: Enable
1.3.6.1.4.1.4756.20.441.20.1.460ColumneddLoopProtectionPort4ActionRemoteAread-writecurrentEDD Series card Loop Protection Configuration for Port 4: Port Configuration - Action 0: Shutdown Port 1: Shutdown Port And Log 2: Log Only
1.3.6.1.4.1.4756.20.441.20.1.461ColumneddLoopProtectionPort4TxModeRemoteAread-writecurrentEDD Series card Loop Protection Configuration for Port 41: Port Configuration - Tx Mode 0: Disable 1: Enable
1.3.6.1.4.1.4756.20.441.20.1.462ColumneddLoopProtectionPort1ActionStsRemoteAread-onlycurrentEDD Series card Loop Protection Status for Port 1: Action
1.3.6.1.4.1.4756.20.441.20.1.463ColumneddLoopProtectionPort1TransStsRemoteAread-onlycurrentEDD Series card Loop Protection Status for Port 1: Transmit
1.3.6.1.4.1.4756.20.441.20.1.464ColumneddLoopProtectionPort1LoopsStsRemoteAread-onlycurrentEDD Series card Loop Protection Status for Port 1: Loops
1.3.6.1.4.1.4756.20.441.20.1.465ColumneddLoopProtectionPort1StatusRemoteAread-onlycurrentEDD Series card Loop Protection Status for Port 1: Status
1.3.6.1.4.1.4756.20.441.20.1.466ColumneddLoopProtectionPort1LoopStsRemoteAread-onlycurrentEDD Series card Loop Protection Status for Port 1: Loop
1.3.6.1.4.1.4756.20.441.20.1.467ColumneddLoopProtectionPort1TimeOfLastLoopRemoteAread-onlycurrentEDD Series card Loop Protection Status for Port 1: Time of Last Loop
1.3.6.1.4.1.4756.20.441.20.1.468ColumneddLoopProtectionPort2ActionStsRemoteAread-onlycurrentEDD Series card Loop Protection Status for Port 2: Action
1.3.6.1.4.1.4756.20.441.20.1.469ColumneddLoopProtectionPort2TransStsRemoteAread-onlycurrentEDD Series card Loop Protection Status for Port 2: Transmit
1.3.6.1.4.1.4756.20.441.20.1.470ColumneddLoopProtectionPort2LoopsStsRemoteAread-onlycurrentEDD Series card Loop Protection Status for Port 2: Loops
1.3.6.1.4.1.4756.20.441.20.1.471ColumneddLoopProtectionPort2StatusRemoteAread-onlycurrentEDD Series card Loop Protection Status for Port 2: Status
1.3.6.1.4.1.4756.20.441.20.1.472ColumneddLoopProtectionPort2LoopStsRemoteAread-onlycurrentEDD Series card Loop Protection Status for Port 2: Loop
1.3.6.1.4.1.4756.20.441.20.1.473ColumneddLoopProtectionPort2TimeOfLastLoopRemoteAread-onlycurrentEDD Series card Loop Protection Status for Port 2: Time of Last Loop
1.3.6.1.4.1.4756.20.441.20.1.474ColumneddLoopProtectionPort3ActionStsRemoteAread-onlycurrentEDD Series card Loop Protection Status for Port 3: Action
1.3.6.1.4.1.4756.20.441.20.1.475ColumneddLoopProtectionPort3TransStsRemoteAread-onlycurrentEDD Series card Loop Protection Status for Port 3: Transmit
1.3.6.1.4.1.4756.20.441.20.1.476ColumneddLoopProtectionPort3LoopsStsRemoteAread-onlycurrentEDD Series card Loop Protection Status for Port 3: Loops
1.3.6.1.4.1.4756.20.441.20.1.477ColumneddLoopProtectionPort3StatusRemoteAread-onlycurrentEDD Series card Loop Protection Status for Port 3: Status
1.3.6.1.4.1.4756.20.441.20.1.478ColumneddLoopProtectionPort3LoopStsRemoteAread-onlycurrentEDD Series card Loop Protection Status for Port 3: Loop
1.3.6.1.4.1.4756.20.441.20.1.479ColumneddLoopProtectionPort3TimeOfLastLoopRemoteAread-onlycurrentEDD Series card Loop Protection Status for Port 3: Time of Last Loop
1.3.6.1.4.1.4756.20.441.20.1.480ColumneddLoopProtectionPort4ActionStsRemoteAread-onlycurrentEDD Series card Loop Protection Status for Port 4: Action
1.3.6.1.4.1.4756.20.441.20.1.481ColumneddLoopProtectionPort4TransStsRemoteAread-onlycurrentEDD Series card Loop Protection Status for Port 4: Transmit
1.3.6.1.4.1.4756.20.441.20.1.482ColumneddLoopProtectionPort4LoopsStsRemoteAread-onlycurrentEDD Series card Loop Protection Status for Port 4: Loops
1.3.6.1.4.1.4756.20.441.20.1.483ColumneddLoopProtectionPort4StatusRemoteAread-onlycurrentEDD Series card Loop Protection Status for Port 4: Status
1.3.6.1.4.1.4756.20.441.20.1.484ColumneddLoopProtectionPort4LoopStsRemoteAread-onlycurrentEDD Series card Loop Protection Status for Port 4: Loop
1.3.6.1.4.1.4756.20.441.20.1.485ColumneddLoopProtectionPort4TimeOfLastLoopRemoteAread-onlycurrentEDD Series card Loop Protection Status for Port 4: Time of Last Loop
1.3.6.1.4.1.4756.20.441.20.1.486ColumneddSTPProtocolVersionRemoteAread-writecurrentEDD Series card STP Bridge Configuration: Basic Settings - Protocol Version 0: STP 1: RSTP 2: MSTP
1.3.6.1.4.1.4756.20.441.20.1.487ColumneddSTPBridgePriorityRemoteAread-writecurrentEDD Series card STP Bridge Configuration: Basic Settings - Bridge Priority 0: 0 1: 4096 2: 8192 3: 12288 4: 16384 5: 20480 6: 24576 7: 28672 8: 32768 9: 36864 …
1.3.6.1.4.1.4756.20.441.20.1.488ColumneddSTPForwardDelayRemoteAread-writecurrentEDD Series card STP Bridge Configuration: Basic Settings - Forward Delay
1.3.6.1.4.1.4756.20.441.20.1.489ColumneddSTPMaxAgeRemoteAread-writecurrentEDD Series card STP Bridge Configuration: Basic Settings - Max Age
1.3.6.1.4.1.4756.20.441.20.1.490ColumneddSTPMaximumHopCountRemoteAread-writecurrentEDD Series card STP Bridge Configuration: Basic Settings - Maximum Hop Count
1.3.6.1.4.1.4756.20.441.20.1.491ColumneddSTPTransmitHoldCountRemoteAread-writecurrentEDD Series card STP Bridge Configuration: Basic Settings - Transmit Hold Count
1.3.6.1.4.1.4756.20.441.20.1.492ColumneddSTPEdgePortBPDUFilteringRemoteAread-writecurrentEDD Series card STP Bridge Configuration: Advanced Settings - Edge Port BPDU Filtering 0: Off 1: On
1.3.6.1.4.1.4756.20.441.20.1.493ColumneddSTPEdgePortBPDUGuardRemoteAread-writecurrentEDD Series card STP Bridge Configuration: Advanced Settings - Edge Port BPDU Guard 0: Off 1: On
1.3.6.1.4.1.4756.20.441.20.1.494ColumneddSTPPortErrorRecoveryTimeoutRemoteAread-writecurrentEDD Series card STP Bridge Configuration: Advanced Settings - Port Error Recovery Timeout 0: Off 1: On
1.3.6.1.4.1.4756.20.441.20.1.495ColumneddMSTIConfigurationNameRemoteAread-writecurrentEDD Series card MSTI Configuration: Configuration Identification - Configuration Name
1.3.6.1.4.1.4756.20.441.20.1.496ColumneddMSTIConfigurationRevisionRemoteAread-writecurrentEDD Series card MSTI Configuration: Configuration Identification - Configuration Revision
1.3.6.1.4.1.4756.20.441.20.1.497ColumneddMSTI1VLANsMappingRemoteAread-writecurrentEDD Series card MSTI Configuration: MSTI Mapping - MSTI 1
1.3.6.1.4.1.4756.20.441.20.1.498ColumneddMSTI2VLANsMappingRemoteAread-writecurrentEDD Series card MSTI Configuration: MSTI Mapping - MSTI 2
1.3.6.1.4.1.4756.20.441.20.1.499ColumneddMSTI3VLANsMappingRemoteAread-writecurrentEDD Series card MSTI Configuration: MSTI Mapping - MSTI 3
1.3.6.1.4.1.4756.20.441.20.1.500ColumneddMSTI4VLANsMappingRemoteAread-writecurrentEDD Series card MSTI Configuration: MSTI Mapping - MSTI 4
1.3.6.1.4.1.4756.20.441.20.1.501ColumneddMSTI5VLANsMappingRemoteAread-writecurrentEDD Series card MSTI Configuration: MSTI Mapping - MSTI 5
1.3.6.1.4.1.4756.20.441.20.1.502ColumneddMSTI6VLANsMappingRemoteAread-writecurrentEDD Series card MSTI Configuration: MSTI Mapping - MSTI 6
1.3.6.1.4.1.4756.20.441.20.1.503ColumneddMSTI7VLANsMappingRemoteAread-writecurrentEDD Series card MSTI Configuration: MSTI Mapping - MSTI 7
1.3.6.1.4.1.4756.20.441.20.1.504ColumneddCISTAggregatedSTPEnabledRemoteAread-writecurrentEDD Series card STP CIST Port Configuration: CIST Aggregated Port Configuration - STP Enabled
1.3.6.1.4.1.4756.20.441.20.1.505ColumneddCISTAggregatedPathCostRemoteAread-writecurrentEDD Series card STP CIST Port Configuration: CIST Aggregated Port Configuration - Path Cost Valid values are in the range 0 to 200000000. Setting 0 means Auto …
1.3.6.1.4.1.4756.20.441.20.1.506ColumneddCISTAggregatedPriorityRemoteAread-writecurrentEDD Series card STP CIST Port Configuration: CIST Aggregated Port Configuration - Priority
1.3.6.1.4.1.4756.20.441.20.1.507ColumneddCISTAggregatedAdminEdgeRemoteAread-writecurrentEDD Series card STP CIST Port Configuration: CIST Aggregated Port Configuration - STP Enabled 0: Non-edge 1: Edge
1.3.6.1.4.1.4756.20.441.20.1.508ColumneddCISTAggregatedAutoEdgeRemoteAread-writecurrentEDD Series card STP CIST Port Configuration: CIST Aggregated Port Configuration - Auto Edge 0: Non-edge 1: Edge
1.3.6.1.4.1.4756.20.441.20.1.509ColumneddCISTAggregatedRestrictedRoleRemoteAread-writecurrentEDD Series card STP CIST Port Configuration: CIST Aggregated Port Configuration - Restricted Role 0: Non-edge 1: Edge
1.3.6.1.4.1.4756.20.441.20.1.510ColumneddCISTAggregatedRestrictedTCNRemoteAread-writecurrentEDD Series card STP CIST Port Configuration: CIST Aggregated Port Configuration - Restricted TCN 0: Non-edge 1: Edge
1.3.6.1.4.1.4756.20.441.20.1.511ColumneddCISTAggregatedBPDUGuardRemoteAread-writecurrentEDD Series card STP CIST Port Configuration: CIST Aggregated Port Configuration - BPDU Guard 0: Non-edge 1: Edge
1.3.6.1.4.1.4756.20.441.20.1.512ColumneddCISTAggregatedPointToPointRemoteAread-writecurrentEDD Series card STP CIST Port Configuration: CIST Aggregated Port Configuration - Point-to-point 0: Forced True 1: Forced False 2: Auto
1.3.6.1.4.1.4756.20.441.20.1.513ColumneddCISTPort1STPEnabledRemoteAread-writecurrentEDD Series card STP CIST Port Configuration: CIST Normal Port1 Configuration - STP Enabled
1.3.6.1.4.1.4756.20.441.20.1.514ColumneddCISTPort1PathCostRemoteAread-writecurrentEDD Series card STP CIST Port Configuration: CIST Normal Port1 Configuration - Path Cost Valid values are in the range 0 to 200000000. Setting 0 means Auto pat…
1.3.6.1.4.1.4756.20.441.20.1.515ColumneddCISTPort1PriorityRemoteAread-writecurrentEDD Series card STP CIST Port Configuration: CIST Normal Port1 Configuration - Priority
1.3.6.1.4.1.4756.20.441.20.1.516ColumneddCISTPort1AdminEdgeRemoteAread-writecurrentEDD Series card STP CIST Port Configuration: CIST Normal Port1 Configuration - STP Enabled 0: Non-edge 1: Edge
1.3.6.1.4.1.4756.20.441.20.1.517ColumneddCISTPort1AutoEdgeRemoteAread-writecurrentEDD Series card STP CIST Port Configuration: CIST Normal Port1 Configuration - Auto Edge 0: Non-edge 1: Edge
1.3.6.1.4.1.4756.20.441.20.1.518ColumneddCISTPort1RestrictedRoleRemoteAread-writecurrentEDD Series card STP CIST Port Configuration: CIST Normal Port1 Configuration - Restricted Role 0: Non-edge 1: Edge
1.3.6.1.4.1.4756.20.441.20.1.519ColumneddCISTPort1RestrictedTCNRemoteAread-writecurrentEDD Series card STP CIST Port Configuration: CIST Normal Port1 Configuration - Restricted TCN 0: Non-edge 1: Edge
1.3.6.1.4.1.4756.20.441.20.1.520ColumneddCISTPort1BPDUGuardRemoteAread-writecurrentEDD Series card STP CIST Port Configuration: CIST Normal Port1 Configuration - BPDU Guard 0: Non-edge 1: Edge
1.3.6.1.4.1.4756.20.441.20.1.521ColumneddCISTPort1PointToPointRemoteAread-writecurrentEDD Series card STP CIST Port Configuration: CIST Normal Port1 Configuration - Point-to-point 0: Forced True 1: Forced False 2: Auto
1.3.6.1.4.1.4756.20.441.20.1.522ColumneddCISTPort2STPEnabledRemoteAread-writecurrentEDD Series card STP CIST Port Configuration: CIST Normal Port2 Configuration - STP Enabled
1.3.6.1.4.1.4756.20.441.20.1.523ColumneddCISTPort2PathCostRemoteAread-writecurrentEDD Series card STP CIST Port Configuration: CIST Normal Port2 Configuration - Path Cost Valid values are in the range 0 to 200000000. Setting 0 means Auto pat…
1.3.6.1.4.1.4756.20.441.20.1.524ColumneddCISTPort2PriorityRemoteAread-writecurrentEDD Series card STP CIST Port Configuration: CIST Normal Port2 Configuration - Priority
1.3.6.1.4.1.4756.20.441.20.1.525ColumneddCISTPort2AdminEdgeRemoteAread-writecurrentEDD Series card STP CIST Port Configuration: CIST Normal Port2 Configuration - STP Enabled 0: Non-edge 1: Edge
1.3.6.1.4.1.4756.20.441.20.1.526ColumneddCISTPort2AutoEdgeRemoteAread-writecurrentEDD Series card STP CIST Port Configuration: CIST Normal Port2 Configuration - Auto Edge 0: Non-edge 1: Edge
1.3.6.1.4.1.4756.20.441.20.1.527ColumneddCISTPort2RestrictedRoleRemoteAread-writecurrentEDD Series card STP CIST Port Configuration: CIST Normal Port2 Configuration - Restricted Role 0: Non-edge 1: Edge
1.3.6.1.4.1.4756.20.441.20.1.528ColumneddCISTPort2RestrictedTCNRemoteAread-writecurrentEDD Series card STP CIST Port Configuration: CIST Normal Port2 Configuration - Restricted TCN 0: Non-edge 1: Edge
1.3.6.1.4.1.4756.20.441.20.1.529ColumneddCISTPort2BPDUGuardRemoteAread-writecurrentEDD Series card STP CIST Port Configuration: CIST Normal Port2 Configuration - BPDU Guard 0: Non-edge 1: Edge
1.3.6.1.4.1.4756.20.441.20.1.530ColumneddCISTPort2PointToPointRemoteAread-writecurrentEDD Series card STP CIST Port Configuration: CIST Normal Port2 Configuration - Point-to-point 0: Forced True 1: Forced False 2: Auto
1.3.6.1.4.1.4756.20.441.20.1.531ColumneddCISTPort3STPEnabledRemoteAread-writecurrentEDD Series card STP CIST Port Configuration: CIST Normal Port3 Configuration - STP Enabled
1.3.6.1.4.1.4756.20.441.20.1.532ColumneddCISTPort3PathCostRemoteAread-writecurrentEDD Series card STP CIST Port Configuration: CIST Normal Port3 Configuration - Path Cost Valid values are in the range 0 to 200000000. Setting 0 means Auto pat…
1.3.6.1.4.1.4756.20.441.20.1.533ColumneddCISTPort3PriorityRemoteAread-writecurrentEDD Series card STP CIST Port Configuration: CIST Normal Port3 Configuration - Priority
1.3.6.1.4.1.4756.20.441.20.1.534ColumneddCISTPort3AdminEdgeRemoteAread-writecurrentEDD Series card STP CIST Port Configuration: CIST Normal Port3 Configuration - STP Enabled 0: Non-edge 1: Edge
1.3.6.1.4.1.4756.20.441.20.1.535ColumneddCISTPort3AutoEdgeRemoteAread-writecurrentEDD Series card STP CIST Port Configuration: CIST Normal Port3 Configuration - Auto Edge 0: Non-edge 1: Edge
1.3.6.1.4.1.4756.20.441.20.1.536ColumneddCISTPort3RestrictedRoleRemoteAread-writecurrentEDD Series card STP CIST Port Configuration: CIST Normal Port3 Configuration - Restricted Role 0: Non-edge 1: Edge
1.3.6.1.4.1.4756.20.441.20.1.537ColumneddCISTPort3RestrictedTCNRemoteAread-writecurrentEDD Series card STP CIST Port Configuration: CIST Normal Port3 Configuration - Restricted TCN 0: Non-edge 1: Edge
1.3.6.1.4.1.4756.20.441.20.1.538ColumneddCISTPort3BPDUGuardRemoteAread-writecurrentEDD Series card STP CIST Port Configuration: CIST Normal Port3 Configuration - BPDU Guard 0: Non-edge 1: Edge
1.3.6.1.4.1.4756.20.441.20.1.539ColumneddCISTPort3PointToPointRemoteAread-writecurrentEDD Series card STP CIST Port Configuration: CIST Normal Port3 Configuration - Point-to-point 0: Forced True 1: Forced False 2: Auto
1.3.6.1.4.1.4756.20.441.20.1.540ColumneddCISTPort4STPEnabledRemoteAread-writecurrentEDD Series card STP CIST Port Configuration: CIST Normal Port4 Configuration - STP Enabled
1.3.6.1.4.1.4756.20.441.20.1.541ColumneddCISTPort4PathCostRemoteAread-writecurrentEDD Series card STP CIST Port Configuration: CIST Normal Port4 Configuration - Path Cost Valid values are in the range 0 to 200000000. Setting 0 means Auto pat…
1.3.6.1.4.1.4756.20.441.20.1.542ColumneddCISTPort4PriorityRemoteAread-writecurrentEDD Series card STP CIST Port Configuration: CIST Normal Port4 Configuration - Priority
1.3.6.1.4.1.4756.20.441.20.1.543ColumneddCISTPort4AdminEdgeRemoteAread-writecurrentEDD Series card STP CIST Port Configuration: CIST Normal Port4 Configuration - STP Enabled 0: Non-edge 1: Edge
1.3.6.1.4.1.4756.20.441.20.1.544ColumneddCISTPort4AutoEdgeRemoteAread-writecurrentEDD Series card STP CIST Port Configuration: CIST Normal Port4 Configuration - Auto Edge 0: Non-edge 1: Edge
1.3.6.1.4.1.4756.20.441.20.1.545ColumneddCISTPort4RestrictedRoleRemoteAread-writecurrentEDD Series card STP CIST Port Configuration: CIST Normal Port4 Configuration - Restricted Role 0: Non-edge 1: Edge
1.3.6.1.4.1.4756.20.441.20.1.546ColumneddCISTPort4RestrictedTCNRemoteAread-writecurrentEDD Series card STP CIST Port Configuration: CIST Normal Port4 Configuration - Restricted TCN 0: Non-edge 1: Edge
1.3.6.1.4.1.4756.20.441.20.1.547ColumneddCISTPort4BPDUGuardRemoteAread-writecurrentEDD Series card STP CIST Port Configuration: CIST Normal Port4 Configuration - BPDU Guard 0: Non-edge 1: Edge
1.3.6.1.4.1.4756.20.441.20.1.548ColumneddCISTPort4PointToPointRemoteAread-writecurrentEDD Series card STP CIST Port Configuration: CIST Normal Port4 Configuration - Point-to-point 0: Forced True 1: Forced False 2: Auto
1.3.6.1.4.1.4756.20.441.20.1.549ColumneddMSTI1AggregatedPathCostRemoteAread-writecurrentEDD Series card MSTI Port Configuration: MSTI1 Aggregated Ports Configuration - Path Cost Valid values are in the range 0 to 200000000. Setting 0 means Auto pa…
1.3.6.1.4.1.4756.20.441.20.1.550ColumneddMSTI1AggregatedPriorityRemoteAread-writecurrentEDD Series card MSTI Port Configuration: MSTI1 Aggregated Ports Configuration - Priority
1.3.6.1.4.1.4756.20.441.20.1.551ColumneddMSTI1Port1PathCostRemoteAread-writecurrentEDD Series card MSTI Port Configuration: MSTI1 Normal Port1 Configuration - Path Cost Valid values are in the range 0 to 200000000. Setting 0 means Auto path c…
1.3.6.1.4.1.4756.20.441.20.1.552ColumneddMSTI1Port1PriorityRemoteAread-writecurrentEDD Series card MSTI Port Configuration: MSTI1 Normal Port1 Configuration - Priority
1.3.6.1.4.1.4756.20.441.20.1.553ColumneddMSTI1Port2PathCostRemoteAread-writecurrentEDD Series card MSTI Port Configuration: MSTI1 Normal Port2 Configuration - Path Cost Valid values are in the range 0 to 200000000. Setting 0 means Auto path c…
1.3.6.1.4.1.4756.20.441.20.1.554ColumneddMSTI1Port2PriorityRemoteAread-writecurrentEDD Series card MSTI Port Configuration: MSTI1 Normal Port2 Configuration - Priority
1.3.6.1.4.1.4756.20.441.20.1.555ColumneddMSTI1Port3PathCostRemoteAread-writecurrentEDD Series card MSTI Port Configuration: MSTI1 Normal Port3 Configuration - Path Cost Valid values are in the range 0 to 200000000. Setting 0 means Auto path c…
1.3.6.1.4.1.4756.20.441.20.1.556ColumneddMSTI1Port3PriorityRemoteAread-writecurrentEDD Series card MSTI Port Configuration: MSTI1 Normal Port3 Configuration - Priority
1.3.6.1.4.1.4756.20.441.20.1.557ColumneddMSTI1Port4PathCostRemoteAread-writecurrentEDD Series card MSTI Port Configuration: MSTI1 Normal Port4 Configuration - Path Cost Valid values are in the range 0 to 200000000. Setting 0 means Auto path c…
1.3.6.1.4.1.4756.20.441.20.1.558ColumneddMSTI1Port4PriorityRemoteAread-writecurrentEDD Series card MSTI Port Configuration: MSTI1 Normal Port4 Configuration - Priority
1.3.6.1.4.1.4756.20.441.20.1.559ColumneddMSTI2AggregatedPathCostRemoteAread-writecurrentEDD Series card MSTI Port Configuration: MSTI2 Aggregated Ports Configuration - Path Cost Valid values are in the range 0 to 200000000. Setting 0 means Auto pa…
1.3.6.1.4.1.4756.20.441.20.1.560ColumneddMSTI2AggregatedPriorityRemoteAread-writecurrentEDD Series card MSTI Port Configuration: MSTI2 Aggregated Ports Configuration - Priority
1.3.6.1.4.1.4756.20.441.20.1.561ColumneddMSTI2Port1PathCostRemoteAread-writecurrentEDD Series card MSTI Port Configuration: MSTI2 Normal Port1 Configuration - Path Cost Valid values are in the range 0 to 200000000. Setting 0 means Auto path c…
1.3.6.1.4.1.4756.20.441.20.1.562ColumneddMSTI2Port1PriorityRemoteAread-writecurrentEDD Series card MSTI Port Configuration: MSTI2 Normal Port1 Configuration - Priority
1.3.6.1.4.1.4756.20.441.20.1.563ColumneddMSTI2Port2PathCostRemoteAread-writecurrentEDD Series card MSTI Port Configuration: MSTI2 Normal Port2 Configuration - Path Cost Valid values are in the range 0 to 200000000. Setting 0 means Auto path c…
1.3.6.1.4.1.4756.20.441.20.1.564ColumneddMSTI2Port2PriorityRemoteAread-writecurrentEDD Series card MSTI Port Configuration: MSTI2 Normal Port2 Configuration - Priority
1.3.6.1.4.1.4756.20.441.20.1.565ColumneddMSTI2Port3PathCostRemoteAread-writecurrentEDD Series card MSTI Port Configuration: MSTI2 Normal Port3 Configuration - Path Cost Valid values are in the range 0 to 200000000. Setting 0 means Auto path c…
1.3.6.1.4.1.4756.20.441.20.1.566ColumneddMSTI2Port3PriorityRemoteAread-writecurrentEDD Series card MSTI Port Configuration: MSTI2 Normal Port3 Configuration - Priority
1.3.6.1.4.1.4756.20.441.20.1.567ColumneddMSTI2Port4PathCostRemoteAread-writecurrentEDD Series card MSTI Port Configuration: MSTI2 Normal Port4 Configuration - Path Cost Valid values are in the range 0 to 200000000. Setting 0 means Auto path c…
1.3.6.1.4.1.4756.20.441.20.1.568ColumneddMSTI2Port4PriorityRemoteAread-writecurrentEDD Series card MSTI Port Configuration: MSTI2 Normal Port4 Configuration - Priority
1.3.6.1.4.1.4756.20.441.20.1.569ColumneddMSTI3AggregatedPathCostRemoteAread-writecurrentEDD Series card MSTI Port Configuration: MSTI3 Aggregated Ports Configuration - Path Cost Valid values are in the range 0 to 200000000. Setting 0 means Auto pa…
1.3.6.1.4.1.4756.20.441.20.1.570ColumneddMSTI3AggregatedPriorityRemoteAread-writecurrentEDD Series card MSTI Port Configuration: MSTI3 Aggregated Ports Configuration - Priority
1.3.6.1.4.1.4756.20.441.20.1.571ColumneddMSTI3Port1PathCostRemoteAread-writecurrentEDD Series card MSTI Port Configuration: MSTI3 Normal Port1 Configuration - Path Cost Valid values are in the range 0 to 200000000. Setting 0 means Auto path c…
1.3.6.1.4.1.4756.20.441.20.1.572ColumneddMSTI3Port1PriorityRemoteAread-writecurrentEDD Series card MSTI Port Configuration: MSTI3 Normal Port1 Configuration - Priority
1.3.6.1.4.1.4756.20.441.20.1.573ColumneddMSTI3Port2PathCostRemoteAread-writecurrentEDD Series card MSTI Port Configuration: MSTI3 Normal Port2 Configuration - Path Cost Valid values are in the range 0 to 200000000. Setting 0 means Auto path c…
1.3.6.1.4.1.4756.20.441.20.1.574ColumneddMSTI3Port2PriorityRemoteAread-writecurrentEDD Series card MSTI Port Configuration: MSTI3 Normal Port2 Configuration - Priority
1.3.6.1.4.1.4756.20.441.20.1.575ColumneddMSTI3Port3PathCostRemoteAread-writecurrentEDD Series card MSTI Port Configuration: MSTI1 Normal Port3 Configuration - Path Cost Valid values are in the range 0 to 200000000. Setting 0 means Auto path c…
1.3.6.1.4.1.4756.20.441.20.1.576ColumneddMSTI3Port3PriorityRemoteAread-writecurrentEDD Series card MSTI Port Configuration: MSTI3 Normal Port3 Configuration - Priority
1.3.6.1.4.1.4756.20.441.20.1.577ColumneddMSTI3Port4PathCostRemoteAread-writecurrentEDD Series card MSTI Port Configuration: MSTI3 Normal Port4 Configuration - Path Cost Valid values are in the range 0 to 200000000. Setting 0 means Auto path c…
1.3.6.1.4.1.4756.20.441.20.1.578ColumneddMSTI3Port4PriorityRemoteAread-writecurrentEDD Series card MSTI Port Configuration: MSTI3 Normal Port4 Configuration - Priority
1.3.6.1.4.1.4756.20.441.20.1.579ColumneddMSTI4AggregatedPathCostRemoteAread-writecurrentEDD Series card MSTI Port Configuration: MSTI4 Aggregated Ports Configuration - Path Cost Valid values are in the range 0 to 200000000. Setting 0 means Auto pa…
1.3.6.1.4.1.4756.20.441.20.1.580ColumneddMSTI4AggregatedPriorityRemoteAread-writecurrentEDD Series card MSTI Port Configuration: MSTI4 Aggregated Ports Configuration - Priority
1.3.6.1.4.1.4756.20.441.20.1.581ColumneddMSTI4Port1PathCostRemoteAread-writecurrentEDD Series card MSTI Port Configuration: MSTI4 Normal Port1 Configuration - Path Cost Valid values are in the range 0 to 200000000. Setting 0 means Auto path c…
1.3.6.1.4.1.4756.20.441.20.1.582ColumneddMSTI4Port1PriorityRemoteAread-writecurrentEDD Series card MSTI Port Configuration: MSTI4 Normal Port1 Configuration - Priority
1.3.6.1.4.1.4756.20.441.20.1.583ColumneddMSTI4Port2PathCostRemoteAread-writecurrentEDD Series card MSTI Port Configuration: MSTI4 Normal Port2 Configuration - Path Cost Valid values are in the range 0 to 200000000. Setting 0 means Auto path c…
1.3.6.1.4.1.4756.20.441.20.1.584ColumneddMSTI4Port2PriorityRemoteAread-writecurrentEDD Series card MSTI Port Configuration: MSTI4 Normal Port2 Configuration - Priority
1.3.6.1.4.1.4756.20.441.20.1.585ColumneddMSTI4Port3PathCostRemoteAread-writecurrentEDD Series card MSTI Port Configuration: MSTI1 Normal Port3 Configuration - Path Cost Valid values are in the range 0 to 200000000. Setting 0 means Auto path c…
1.3.6.1.4.1.4756.20.441.20.1.586ColumneddMSTI4Port3PriorityRemoteAread-writecurrentEDD Series card MSTI Port Configuration: MSTI4 Normal Port3 Configuration - Priority
1.3.6.1.4.1.4756.20.441.20.1.587ColumneddMSTI4Port4PathCostRemoteAread-writecurrentEDD Series card MSTI Port Configuration: MSTI4 Normal Port4 Configuration - Path Cost Valid values are in the range 0 to 200000000. Setting 0 means Auto path c…
1.3.6.1.4.1.4756.20.441.20.1.588ColumneddMSTI4Port4PriorityRemoteAread-writecurrentEDD Series card MSTI Port Configuration: MSTI4 Normal Port4 Configuration - Priority
1.3.6.1.4.1.4756.20.441.20.1.589ColumneddMSTI5AggregatedPathCostRemoteAread-writecurrentEDD Series card MSTI Port Configuration: MSTI5 Aggregated Ports Configuration - Path Cost Valid values are in the range 0 to 200000000. Setting 0 means Auto pa…
1.3.6.1.4.1.4756.20.441.20.1.590ColumneddMSTI5AggregatedPriorityRemoteAread-writecurrentEDD Series card MSTI Port Configuration: MSTI5 Aggregated Ports Configuration - Priority
1.3.6.1.4.1.4756.20.441.20.1.591ColumneddMSTI5Port1PathCostRemoteAread-writecurrentEDD Series card MSTI Port Configuration: MSTI5 Normal Port1 Configuration - Path Cost Valid values are in the range 0 to 200000000. Setting 0 means Auto path c…
1.3.6.1.4.1.4756.20.441.20.1.592ColumneddMSTI5Port1PriorityRemoteAread-writecurrentEDD Series card MSTI Port Configuration: MSTI5 Normal Port1 Configuration - Priority
1.3.6.1.4.1.4756.20.441.20.1.593ColumneddMSTI5Port2PathCostRemoteAread-writecurrentEDD Series card MSTI Port Configuration: MSTI5 Normal Port2 Configuration - Path Cost Valid values are in the range 0 to 200000000. Setting 0 means Auto path c…
1.3.6.1.4.1.4756.20.441.20.1.594ColumneddMSTI5Port2PriorityRemoteAread-writecurrentEDD Series card MSTI Port Configuration: MSTI5 Normal Port2 Configuration - Priority
1.3.6.1.4.1.4756.20.441.20.1.595ColumneddMSTI5Port3PathCostRemoteAread-writecurrentEDD Series card MSTI Port Configuration: MSTI5 Normal Port3 Configuration - Path Cost Valid values are in the range 0 to 200000000. Setting 0 means Auto path c…
1.3.6.1.4.1.4756.20.441.20.1.596ColumneddMSTI5Port3PriorityRemoteAread-writecurrentEDD Series card MSTI Port Configuration: MSTI5 Normal Port3 Configuration - Priority
1.3.6.1.4.1.4756.20.441.20.1.597ColumneddMSTI5Port4PathCostRemoteAread-writecurrentEDD Series card MSTI Port Configuration: MSTI5 Normal Port4 Configuration - Path Cost Valid values are in the range 0 to 200000000. Setting 0 means Auto path c…
1.3.6.1.4.1.4756.20.441.20.1.598ColumneddMSTI5Port4PriorityRemoteAread-writecurrentEDD Series card MSTI Port Configuration: MSTI5 Normal Port4 Configuration - Priority
1.3.6.1.4.1.4756.20.441.20.1.599ColumneddMSTI6AggregatedPathCostRemoteAread-writecurrentEDD Series card MSTI Port Configuration: MSTI6 Aggregated Ports Configuration - Path Cost Valid values are in the range 0 to 200000000. Setting 0 means Auto pa…
1.3.6.1.4.1.4756.20.441.20.1.600ColumneddMSTI6AggregatedPriorityRemoteAread-writecurrentEDD Series card MSTI Port Configuration: MSTI6 Aggregated Ports Configuration - Priority
1.3.6.1.4.1.4756.20.441.20.1.601ColumneddMSTI6Port1PathCostRemoteAread-writecurrentEDD Series card MSTI Port Configuration: MSTI6 Normal Port1 Configuration - Path Cost Valid values are in the range 0 to 200000000. Setting 0 means Auto path c…
1.3.6.1.4.1.4756.20.441.20.1.602ColumneddMSTI6Port1PriorityRemoteAread-writecurrentEDD Series card MSTI Port Configuration: MSTI6 Normal Port1 Configuration - Priority
1.3.6.1.4.1.4756.20.441.20.1.603ColumneddMSTI6Port2PathCostRemoteAread-writecurrentEDD Series card MSTI Port Configuration: MSTI6 Normal Port2 Configuration - Path Cost Valid values are in the range 0 to 200000000. Setting 0 means Auto path c…
1.3.6.1.4.1.4756.20.441.20.1.604ColumneddMSTI6Port2PriorityRemoteAread-writecurrentEDD Series card MSTI Port Configuration: MSTI6 Normal Port2 Configuration - Priority
1.3.6.1.4.1.4756.20.441.20.1.605ColumneddMSTI6Port3PathCostRemoteAread-writecurrentEDD Series card MSTI Port Configuration: MSTI6 Normal Port3 Configuration - Path Cost Valid values are in the range 0 to 200000000. Setting 0 means Auto path c…
1.3.6.1.4.1.4756.20.441.20.1.606ColumneddMSTI6Port3PriorityRemoteAread-writecurrentEDD Series card MSTI Port Configuration: MSTI6 Normal Port3 Configuration - Priority
1.3.6.1.4.1.4756.20.441.20.1.607ColumneddMSTI6Port4PathCostRemoteAread-writecurrentEDD Series card MSTI Port Configuration: MSTI6 Normal Port4 Configuration - Path Cost Valid values are in the range 0 to 200000000. Setting 0 means Auto path c…
1.3.6.1.4.1.4756.20.441.20.1.608ColumneddMSTI6Port4PriorityRemoteAread-writecurrentEDD Series card MSTI Port Configuration: MSTI6 Normal Port4 Configuration - Priority
1.3.6.1.4.1.4756.20.441.20.1.609ColumneddMSTI7AggregatedPathCostRemoteAread-writecurrentEDD Series card MSTI Port Configuration: MSTI7 Aggregated Ports Configuration - Path Cost Valid values are in the range 0 to 200000000. Setting 0 means Auto pa…
1.3.6.1.4.1.4756.20.441.20.1.610ColumneddMSTI7AggregatedPriorityRemoteAread-writecurrentEDD Series card MSTI Port Configuration: MSTI7 Aggregated Ports Configuration - Priority
1.3.6.1.4.1.4756.20.441.20.1.611ColumneddMSTI7Port1PathCostRemoteAread-writecurrentEDD Series card MSTI Port Configuration: MSTI1 Normal Port1 Configuration - Path Cost Valid values are in the range 0 to 200000000. Setting 0 means Auto path c…
1.3.6.1.4.1.4756.20.441.20.1.612ColumneddMSTI7Port1PriorityRemoteAread-writecurrentEDD Series card MSTI Port Configuration: MSTI1 Normal Port7 Configuration - Priority
1.3.6.1.4.1.4756.20.441.20.1.613ColumneddMSTI7Port2PathCostRemoteAread-writecurrentEDD Series card MSTI Port Configuration: MSTI7 Normal Port2 Configuration - Path Cost Valid values are in the range 0 to 200000000. Setting 0 means Auto path c…
1.3.6.1.4.1.4756.20.441.20.1.614ColumneddMSTI7Port2PriorityRemoteAread-writecurrentEDD Series card MSTI Port Configuration: MSTI7 Normal Port2 Configuration - Priority
1.3.6.1.4.1.4756.20.441.20.1.615ColumneddMSTI7Port3PathCostRemoteAread-writecurrentEDD Series card MSTI Port Configuration: MSTI7 Normal Port3 Configuration - Path Cost Valid values are in the range 0 to 200000000. Setting 0 means Auto path c…
1.3.6.1.4.1.4756.20.441.20.1.616ColumneddMSTI7Port3PriorityRemoteAread-writecurrentEDD Series card MSTI Port Configuration: MSTI7 Normal Port3 Configuration - Priority
1.3.6.1.4.1.4756.20.441.20.1.617ColumneddMSTI7Port4PathCostRemoteAread-writecurrentEDD Series card MSTI Port Configuration: MSTI7 Normal Port4 Configuration - Path Cost Valid values are in the range 0 to 200000000. Setting 0 means Auto path c…
1.3.6.1.4.1.4756.20.441.20.1.618ColumneddMSTI7Port4PriorityRemoteAread-writecurrentEDD Series card MSTI Port Configuration: MSTI7 Normal Port4 Configuration - Priority
1.3.6.1.4.1.4756.20.441.20.1.619ColumneddCISTBridgeIDRemoteAread-onlycurrentEDD Series card STP Bridges status: CIST - Bridge ID
1.3.6.1.4.1.4756.20.441.20.1.620ColumneddCISTRootIDRemoteAread-onlycurrentEDD Series card STP Bridges status: CIST - Root ID
1.3.6.1.4.1.4756.20.441.20.1.621ColumneddCISTRootPortRemoteAread-onlycurrentEDD Series card STP Bridges status: CIST - Root Port
1.3.6.1.4.1.4756.20.441.20.1.622ColumneddCISTRootCostRemoteAread-onlycurrentEDD Series card STP Bridges status: CIST - Root Cost
1.3.6.1.4.1.4756.20.441.20.1.623ColumneddCISTTopologyFlagRemoteAread-onlycurrentEDD Series card STP Bridges status: CIST - Topology Flag
1.3.6.1.4.1.4756.20.441.20.1.624ColumneddCISTTopologyChangeLastRemoteAread-onlycurrentEDD Series card STP Bridges status: CIST - Topology Change Last
1.3.6.1.4.1.4756.20.441.20.1.625ColumneddMSTI1BridgeIDRemoteAread-onlycurrentEDD Series card STP Bridges status: MSTI1 - Bridge ID
1.3.6.1.4.1.4756.20.441.20.1.626ColumneddMSTI1RootIDRemoteAread-onlycurrentEDD Series card STP Bridges status: MSTI1 - Root ID
1.3.6.1.4.1.4756.20.441.20.1.627ColumneddMSTI1RootPortRemoteAread-onlycurrentEDD Series card STP Bridges status: MSTI1 - Root ID
1.3.6.1.4.1.4756.20.441.20.1.628ColumneddMSTI1RootCostRemoteAread-onlycurrentEDD Series card STP Bridges status: MSTI1 - Root Cost
1.3.6.1.4.1.4756.20.441.20.1.629ColumneddMSTI1TopologyFlagRemoteAread-onlycurrentEDD Series card STP Bridges status: MSTI1 - Topology Flag
1.3.6.1.4.1.4756.20.441.20.1.630ColumneddMSTI1TopologyChangeLastRemoteAread-onlycurrentEDD Series card STP Bridges status: MSTI1 - Topology Change Last
1.3.6.1.4.1.4756.20.441.20.1.631ColumneddMSTI2BridgeIDRemoteAread-onlycurrentEDD Series card STP Bridges status: MSTI2 - Bridge ID
1.3.6.1.4.1.4756.20.441.20.1.632ColumneddMSTI2RootIDRemoteAread-onlycurrentEDD Series card STP Bridges status: MSTI2 - Root ID
1.3.6.1.4.1.4756.20.441.20.1.633ColumneddMSTI2RootPortRemoteAread-onlycurrentEDD Series card STP Bridges status: MSTI2 - Root ID
1.3.6.1.4.1.4756.20.441.20.1.634ColumneddMSTI2RootCostRemoteAread-onlycurrentEDD Series card STP Bridges status: MSTI2 - Root Cost
1.3.6.1.4.1.4756.20.441.20.1.635ColumneddMSTI2TopologyFlagRemoteAread-onlycurrentEDD Series card STP Bridges status: MSTI2 - Topology Flag
1.3.6.1.4.1.4756.20.441.20.1.636ColumneddMSTI2TopologyChangeLastRemoteAread-onlycurrentEDD Series card STP Bridges status: MSTI2 - Topology Change Last
1.3.6.1.4.1.4756.20.441.20.1.637ColumneddMSTI3BridgeIDRemoteAread-onlycurrentEDD Series card STP Bridges status: MSTI3 - Bridge ID
1.3.6.1.4.1.4756.20.441.20.1.638ColumneddMSTI3RootIDRemoteAread-onlycurrentEDD Series card STP Bridges status: MSTI3 - Root ID
1.3.6.1.4.1.4756.20.441.20.1.639ColumneddMSTI3RootPortRemoteAread-onlycurrentEDD Series card STP Bridges status: MSTI3 - Root ID
1.3.6.1.4.1.4756.20.441.20.1.640ColumneddMSTI3RootCostRemoteAread-onlycurrentEDD Series card STP Bridges status: MSTI3 - Root Cost
1.3.6.1.4.1.4756.20.441.20.1.641ColumneddMSTI3TopologyFlagRemoteAread-onlycurrentEDD Series card STP Bridges status: MSTI3 - Topology Flag
1.3.6.1.4.1.4756.20.441.20.1.642ColumneddMSTI3TopologyChangeLastRemoteAread-onlycurrentEDD Series card STP Bridges status: MSTI3 - Topology Change Last
1.3.6.1.4.1.4756.20.441.20.1.643ColumneddMSTI4BridgeIDRemoteAread-onlycurrentEDD Series card STP Bridges status: MSTI4 - Bridge ID
1.3.6.1.4.1.4756.20.441.20.1.644ColumneddMSTI4RootIDRemoteAread-onlycurrentEDD Series card STP Bridges status: MSTI4 - Root ID
1.3.6.1.4.1.4756.20.441.20.1.645ColumneddMSTI4RootPortRemoteAread-onlycurrentEDD Series card STP Bridges status: MSTI4 - Root ID
1.3.6.1.4.1.4756.20.441.20.1.646ColumneddMSTI4RootCostRemoteAread-onlycurrentEDD Series card STP Bridges status: MSTI4 - Root Cost
1.3.6.1.4.1.4756.20.441.20.1.647ColumneddMSTI4TopologyFlagRemoteAread-onlycurrentEDD Series card STP Bridges status: MSTI4 - Topology Flag
1.3.6.1.4.1.4756.20.441.20.1.648ColumneddMSTI4TopologyChangeLastRemoteAread-onlycurrentEDD Series card STP Bridges status: MSTI4 - Topology Change Last
1.3.6.1.4.1.4756.20.441.20.1.649ColumneddMSTI5BridgeIDRemoteAread-onlycurrentEDD Series card STP Bridges status: MSTI5 - Bridge ID
1.3.6.1.4.1.4756.20.441.20.1.650ColumneddMSTI5RootIDRemoteAread-onlycurrentEDD Series card STP Bridges status: MSTI5 - Root ID
1.3.6.1.4.1.4756.20.441.20.1.651ColumneddMSTI5RootPortRemoteAread-onlycurrentEDD Series card STP Bridges status: MSTI5 - Root ID
1.3.6.1.4.1.4756.20.441.20.1.652ColumneddMSTI5RootCostRemoteAread-onlycurrentEDD Series card STP Bridges status: MSTI5 - Root Cost
1.3.6.1.4.1.4756.20.441.20.1.653ColumneddMSTI5TopologyFlagRemoteAread-onlycurrentEDD Series card STP Bridges status: MSTI5 - Topology Flag
1.3.6.1.4.1.4756.20.441.20.1.654ColumneddMSTI5TopologyChangeLastRemoteAread-onlycurrentEDD Series card STP Bridges status: MSTI5 - Topology Change Last
1.3.6.1.4.1.4756.20.441.20.1.655ColumneddMSTI6BridgeIDRemoteAread-onlycurrentEDD Series card STP Bridges status: MSTI6 - Bridge ID
1.3.6.1.4.1.4756.20.441.20.1.656ColumneddMSTI6RootIDRemoteAread-onlycurrentEDD Series card STP Bridges status: MSTI6 - Root ID
1.3.6.1.4.1.4756.20.441.20.1.657ColumneddMSTI6RootPortRemoteAread-onlycurrentEDD Series card STP Bridges status: MSTI6 - Root ID
1.3.6.1.4.1.4756.20.441.20.1.658ColumneddMSTI6RootCostRemoteAread-onlycurrentEDD Series card STP Bridges status: MSTI6 - Root Cost
1.3.6.1.4.1.4756.20.441.20.1.659ColumneddMSTI6TopologyFlagRemoteAread-onlycurrentEDD Series card STP Bridges status: MSTI6 - Topology Flag
1.3.6.1.4.1.4756.20.441.20.1.660ColumneddMSTI6TopologyChangeLastRemoteAread-onlycurrentEDD Series card STP Bridges status: MSTI6 - Topology Change Last
1.3.6.1.4.1.4756.20.441.20.1.661ColumneddMSTI7BridgeIDRemoteAread-onlycurrentEDD Series card STP Bridges status: MSTI7 - Bridge ID
1.3.6.1.4.1.4756.20.441.20.1.662ColumneddMSTI7RootIDRemoteAread-onlycurrentEDD Series card STP Bridges status: MSTI7 - Root ID
1.3.6.1.4.1.4756.20.441.20.1.663ColumneddMSTI7RootPortRemoteAread-onlycurrentEDD Series card STP Bridges status: MSTI7 - Root ID
1.3.6.1.4.1.4756.20.441.20.1.664ColumneddMSTI7RootCostRemoteAread-onlycurrentEDD Series card STP Bridges status: MSTI7 - Root Cost
1.3.6.1.4.1.4756.20.441.20.1.665ColumneddMSTI7TopologyFlagRemoteAread-onlycurrentEDD Series card STP Bridges status: MSTI7 - Topology Flag
1.3.6.1.4.1.4756.20.441.20.1.666ColumneddMSTI7TopologyChangeLastRemoteAread-onlycurrentEDD Series card STP Bridges status: MSTI7 - Topology Change Last
1.3.6.1.4.1.4756.20.441.20.1.667ColumneddSTPPortStatusInst1PortRemoteAread-onlycurrentEDD Series card STP Port status: Instance1 - Port
1.3.6.1.4.1.4756.20.441.20.1.668ColumneddSTPPortStatusInst1CISTRoleRemoteAread-onlycurrentEDD Series card STP Port status: Instance1 - CIST Role
1.3.6.1.4.1.4756.20.441.20.1.669ColumneddSTPPortStatusInst1CISTStateRemoteAread-onlycurrentEDD Series card STP Port status: Instance1 - CIST State
1.3.6.1.4.1.4756.20.441.20.1.670ColumneddSTPPortStatusInst1UptimeRemoteAread-onlycurrentEDD Series card STP Port status: Instance1 -Uptime
1.3.6.1.4.1.4756.20.441.20.1.671ColumneddSTPPortStatusInst2PortRemoteAread-onlycurrentEDD Series card STP Port status: Instance2 - Port
1.3.6.1.4.1.4756.20.441.20.1.672ColumneddSTPPortStatusInst2CISTRoleRemoteAread-onlycurrentEDD Series card STP Port status: Instance2 - CIST Role
1.3.6.1.4.1.4756.20.441.20.1.673ColumneddSTPPortStatusInst2CISTStateRemoteAread-onlycurrentEDD Series card STP Port status: Instance2 - CIST State
1.3.6.1.4.1.4756.20.441.20.1.674ColumneddSTPPortStatusInst2UptimeRemoteAread-onlycurrentEDD Series card STP Port status: Instance2 -Uptime
1.3.6.1.4.1.4756.20.441.20.1.675ColumneddSTPPortStatusInst3PortRemoteAread-onlycurrentEDD Series card STP Port status: Instance3 - Port
1.3.6.1.4.1.4756.20.441.20.1.676ColumneddSTPPortStatusInst3CISTRoleRemoteAread-onlycurrentEDD Series card STP Port status: Instance3 - CIST Role
1.3.6.1.4.1.4756.20.441.20.1.677ColumneddSTPPortStatusInst3CISTStateRemoteAread-onlycurrentEDD Series card STP Port status: Instance3 - CIST State
1.3.6.1.4.1.4756.20.441.20.1.678ColumneddSTPPortStatusInst3UptimeRemoteAread-onlycurrentEDD Series card STP Port status: Instance3 -Uptime
1.3.6.1.4.1.4756.20.441.20.1.679ColumneddSTPPortStatusInst4PortRemoteAread-onlycurrentEDD Series card STP Port status: Instance4 - Port
1.3.6.1.4.1.4756.20.441.20.1.680ColumneddSTPPortStatusInst4CISTRoleRemoteAread-onlycurrentEDD Series card STP Port status: Instance4 - CIST Role
1.3.6.1.4.1.4756.20.441.20.1.681ColumneddSTPPortStatusInst4CISTStateRemoteAread-onlycurrentEDD Series card STP Port status: Instance4 - CIST State
1.3.6.1.4.1.4756.20.441.20.1.682ColumneddSTPPortStatusInst4UptimeRemoteAread-onlycurrentEDD Series card STP Port status: Instance4 -Uptime
1.3.6.1.4.1.4756.20.441.20.1.683ColumneddSTPStatisticsPort1TxMSTPRemoteAread-onlycurrentEDD Series card STP Port Statistics: Port1 -Transmitted MSTP
1.3.6.1.4.1.4756.20.441.20.1.684ColumneddSTPStatisticsPort1TxRSTPRemoteAread-onlycurrentEDD Series card STP Port Statistics: Port1 -Transmitted RSTP
1.3.6.1.4.1.4756.20.441.20.1.685ColumneddSTPStatisticsPort1TxSTPRemoteAread-onlycurrentEDD Series card STP Port Statistics: Port1 -Transmitted RSTP
1.3.6.1.4.1.4756.20.441.20.1.686ColumneddSTPStatisticsPort1TxTCNRemoteAread-onlycurrentEDD Series card STP Port Statistics: Port1 -Transmitted RSTP
1.3.6.1.4.1.4756.20.441.20.1.687ColumneddSTPStatisticsPort1RxMSTPRemoteAread-onlycurrentEDD Series card STP Port Statistics: Port1 -Received MSTP
1.3.6.1.4.1.4756.20.441.20.1.688ColumneddSTPStatisticsPort1RxRSTPRemoteAread-onlycurrentEDD Series card STP Port Statistics: Port1 -Received RSTP
1.3.6.1.4.1.4756.20.441.20.1.689ColumneddSTPStatisticsPort1RxSTPRemoteAread-onlycurrentEDD Series card STP Port Statistics: Port1 -Received RSTP
1.3.6.1.4.1.4756.20.441.20.1.690ColumneddSTPStatisticsPort1RxTCNRemoteAread-onlycurrentEDD Series card STP Port Statistics: Port1 -Received RSTP
1.3.6.1.4.1.4756.20.441.20.1.691ColumneddSTPStatisticsPort1DiscardUnknowRemoteAread-onlycurrentEDD Series card STP Port Statistics: Port1 -Discarded Unknown
1.3.6.1.4.1.4756.20.441.20.1.692ColumneddSTPStatisticsPort1DiscardIllegalRemoteAread-onlycurrentEDD Series card STP Port Statistics: Port1 -Discarded Illegal
1.3.6.1.4.1.4756.20.441.20.1.693ColumneddSTPStatisticsPort2TxMSTPRemoteAread-onlycurrentEDD Series card STP Port Statistics: Port2 -Transmitted MSTP
1.3.6.1.4.1.4756.20.441.20.1.694ColumneddSTPStatisticsPort2TxRSTPRemoteAread-onlycurrentEDD Series card STP Port Statistics: Port2 -Transmitted RSTP
1.3.6.1.4.1.4756.20.441.20.1.695ColumneddSTPStatisticsPort2TxSTPRemoteAread-onlycurrentEDD Series card STP Port Statistics: Port2 -Transmitted RSTP
1.3.6.1.4.1.4756.20.441.20.1.696ColumneddSTPStatisticsPort2TxTCNRemoteAread-onlycurrentEDD Series card STP Port Statistics: Port2 -Transmitted RSTP
1.3.6.1.4.1.4756.20.441.20.1.697ColumneddSTPStatisticsPort2RxMSTPRemoteAread-onlycurrentEDD Series card STP Port Statistics: Port2 -Received MSTP
1.3.6.1.4.1.4756.20.441.20.1.698ColumneddSTPStatisticsPort2RxRSTPRemoteAread-onlycurrentEDD Series card STP Port Statistics: Port1 -Received RSTP
1.3.6.1.4.1.4756.20.441.20.1.699ColumneddSTPStatisticsPort2RxSTPRemoteAread-onlycurrentEDD Series card STP Port Statistics: Port2 -Received RSTP
1.3.6.1.4.1.4756.20.441.20.1.700ColumneddSTPStatisticsPort2RxTCNRemoteAread-onlycurrentEDD Series card STP Port Statistics: Port2 -Received RSTP
1.3.6.1.4.1.4756.20.441.20.1.701ColumneddSTPStatisticsPort2DiscardUnknowRemoteAread-onlycurrentEDD Series card STP Port Statistics: Port2 -Discarded Unknown
1.3.6.1.4.1.4756.20.441.20.1.702ColumneddSTPStatisticsPort2DiscardIllegalRemoteAread-onlycurrentEDD Series card STP Port Statistics: Port2 -Discarded Illegal
1.3.6.1.4.1.4756.20.441.20.1.703ColumneddSTPStatisticsPort3TxMSTPRemoteAread-onlycurrentEDD Series card STP Port Statistics: Port3 -Transmitted MSTP
1.3.6.1.4.1.4756.20.441.20.1.704ColumneddSTPStatisticsPort3TxRSTPRemoteAread-onlycurrentEDD Series card STP Port Statistics: Port3 -Transmitted RSTP
1.3.6.1.4.1.4756.20.441.20.1.705ColumneddSTPStatisticsPort3TxSTPRemoteAread-onlycurrentEDD Series card STP Port Statistics: Port3 -Transmitted RSTP
1.3.6.1.4.1.4756.20.441.20.1.706ColumneddSTPStatisticsPort3TxTCNRemoteAread-onlycurrentEDD Series card STP Port Statistics: Port3 -Transmitted RSTP
1.3.6.1.4.1.4756.20.441.20.1.707ColumneddSTPStatisticsPort3RxMSTPRemoteAread-onlycurrentEDD Series card STP Port Statistics: Port3 -Received MSTP
1.3.6.1.4.1.4756.20.441.20.1.708ColumneddSTPStatisticsPort3RxRSTPRemoteAread-onlycurrentEDD Series card STP Port Statistics: Port3 -Received RSTP
1.3.6.1.4.1.4756.20.441.20.1.709ColumneddSTPStatisticsPort3RxSTPRemoteAread-onlycurrentEDD Series card STP Port Statistics: Port3 -Received RSTP
1.3.6.1.4.1.4756.20.441.20.1.710ColumneddSTPStatisticsPort3RxTCNRemoteAread-onlycurrentEDD Series card STP Port Statistics: Port3 -Received RSTP
1.3.6.1.4.1.4756.20.441.20.1.711ColumneddSTPStatisticsPort3DiscardUnknowRemoteAread-onlycurrentEDD Series card STP Port Statistics: Port3 -Discarded Unknown
1.3.6.1.4.1.4756.20.441.20.1.712ColumneddSTPStatisticsPort3DiscardIllegalRemoteAread-onlycurrentEDD Series card STP Port Statistics: Port3 -Discarded Illegal
1.3.6.1.4.1.4756.20.441.20.1.713ColumneddSTPStatisticsPort4TxMSTPRemoteAread-onlycurrentEDD Series card STP Port Statistics: Port4 -Transmitted MSTP
1.3.6.1.4.1.4756.20.441.20.1.714ColumneddSTPStatisticsPort4TxRSTPRemoteAread-onlycurrentEDD Series card STP Port Statistics: Port4 -Transmitted RSTP
1.3.6.1.4.1.4756.20.441.20.1.715ColumneddSTPStatisticsPort4TxSTPRemoteAread-onlycurrentEDD Series card STP Port Statistics: Port4 -Transmitted RSTP
1.3.6.1.4.1.4756.20.441.20.1.716ColumneddSTPStatisticsPort4TxTCNRemoteAread-onlycurrentEDD Series card STP Port Statistics: Port4 -Transmitted RSTP
1.3.6.1.4.1.4756.20.441.20.1.717ColumneddSTPStatisticsPort4RxMSTPRemoteAread-onlycurrentEDD Series card STP Port Statistics: Port4 -Received MSTP
1.3.6.1.4.1.4756.20.441.20.1.718ColumneddSTPStatisticsPort4RxRSTPRemoteAread-onlycurrentEDD Series card STP Port Statistics: Port4 -Received RSTP
1.3.6.1.4.1.4756.20.441.20.1.719ColumneddSTPStatisticsPort4RxSTPRemoteAread-onlycurrentEDD Series card STP Port Statistics: Port4 -Received RSTP
1.3.6.1.4.1.4756.20.441.20.1.720ColumneddSTPStatisticsPort4RxTCNRemoteAread-onlycurrentEDD Series card STP Port Statistics: Port4 -Received RSTP
1.3.6.1.4.1.4756.20.441.20.1.721ColumneddSTPStatisticsPort4DiscardUnknowRemoteAread-onlycurrentEDD Series card STP Port Statistics: Port4 -Discarded Unknown
1.3.6.1.4.1.4756.20.441.20.1.722ColumneddSTPStatisticsPort4DiscardIllegalRemoteAread-onlycurrentEDD Series card STP Port Statistics: Port4 -Discarded Illegal
1.3.6.1.4.1.4756.20.441.20.1.723ColumneddSTPStatisticsPortClearCounterRemoteAread-writecurrentEDD Series card STP Port Statistics: Clear Counters 0: OFff 1: Action
1.3.6.1.4.1.4756.20.441.20.1.724ColumneddAllowedAccessVLANsRemoteAread-writecurrentEDD Series card Global VLAN Configuration: Allowed Access VLANs By default, only VLAN 1 is enabled. More VLANs may be created by using a list syntax where the …
1.3.6.1.4.1.4756.20.441.20.1.725ColumneddVlanEthertypeRemoteAread-writecurrentEDD Series card Global VLAN Configuration: Ethertype for Custom S-ports The format of 'Ethernet Type' is restricted to 0x600-0xFFFF
1.3.6.1.4.1.4756.20.441.20.1.726ColumneddPort1VlanModeRemoteAread-writecurrentEDD Series card Port VLAN Configuration : Port1 - Mode 0: Access 1: Trunk 2: Hybrid
1.3.6.1.4.1.4756.20.441.20.1.727ColumneddPort1VlanIDRemoteAread-writecurrentEDD Series card Port VLAN Configuration : Port1 - VLAN ID
1.3.6.1.4.1.4756.20.441.20.1.728ColumneddPort1VlanTypeRemoteAread-writecurrentEDD Series card Port VLAN Configuration : Port1 - VLAN Type 0: Unaware 1: C-port 2: S-port 3: S-custom-port
1.3.6.1.4.1.4756.20.441.20.1.729ColumneddPort1VlanIngressFilteringRemoteAread-writecurrentEDD Series card Port VLAN Configuration : Port1 - Ingress Filtering 0: Off 1: On
1.3.6.1.4.1.4756.20.441.20.1.730ColumneddPort1VlanIngressAcceptanceRemoteAread-writecurrentEDD Series card Port VLAN Configuration : Port1 - Ingress Acceptance 0: Tagged and untagged 1: Tagged only 2: Untagged only
1.3.6.1.4.1.4756.20.441.20.1.731ColumneddPort1VlanEgressTaggingRemoteAread-writecurrentEDD Series card Port VLAN Configuration : Port1 - Egress Tagging 0: Untag port vlan 1: Tag all 2: Untag all
1.3.6.1.4.1.4756.20.441.20.1.732ColumneddPort1AllowedVLANSRemoteAread-writecurrentEDD Series card Global VLAN Configuration: Port1 - Allowed VLANs By default, only VLAN 1 is enabled. More VLANs may be created by using a list syntax where the…
1.3.6.1.4.1.4756.20.441.20.1.733ColumneddPort1ForbiddenVLANSRemoteAread-writecurrentEDD Series card Global VLAN Configuration: Port1 - Forbidden VLANs By default, the field is left blank, which means that the port may become a member of all po…
1.3.6.1.4.1.4756.20.441.20.1.734ColumneddPort2VlanModeRemoteAread-writecurrentEDD Series card Port VLAN Configuration : Port2 - Mode 0: Access 1: Trunk 2: Hybrid
1.3.6.1.4.1.4756.20.441.20.1.735ColumneddPort2VlanIDRemoteAread-writecurrentEDD Series card Port VLAN Configuration : Port2 - VLAN ID
1.3.6.1.4.1.4756.20.441.20.1.736ColumneddPort2VlanTypeRemoteAread-writecurrentEDD Series card Port VLAN Configuration : Port2 - VLAN Type 0: Unaware 1: C-port 2: S-port 3: S-custom-port
1.3.6.1.4.1.4756.20.441.20.1.737ColumneddPort2VlanIngressFilteringRemoteAread-writecurrentEDD Series card Port VLAN Configuration : Port2 - Ingress Filtering 0: Off 1: On
1.3.6.1.4.1.4756.20.441.20.1.738ColumneddPort2VlanIngressAcceptanceRemoteAread-writecurrentEDD Series card Port VLAN Configuration : Por2 - Ingress Acceptance 0: Tagged and untagged 1: Tagged only 2: Untagged only
1.3.6.1.4.1.4756.20.441.20.1.739ColumneddPort2VlanEgressTaggingRemoteAread-writecurrentEDD Series card Port VLAN Configuration : Port2 - Egress Tagging 0: Untag port vlan 1: Tag all 2: Untag all
1.3.6.1.4.1.4756.20.441.20.1.740ColumneddPort2AllowedVLANSRemoteAread-writecurrentEDD Series card Global VLAN Configuration: Port2 - Allowed VLANs By default, only VLAN 1 is enabled. More VLANs may be created by using a list syntax where the…
1.3.6.1.4.1.4756.20.441.20.1.741ColumneddPort2ForbiddenVLANSRemoteAread-writecurrentEDD Series card Global VLAN Configuration: Port2 - Forbidden VLANs By default, the field is left blank, which means that the port may become a member of all po…
1.3.6.1.4.1.4756.20.441.20.1.742ColumneddPort3VlanModeRemoteAread-writecurrentEDD Series card Port VLAN Configuration : Port3 - Mode 0: Access 1: Trunk 2: Hybrid
1.3.6.1.4.1.4756.20.441.20.1.743ColumneddPort3VlanIDRemoteAread-writecurrentEDD Series card Port VLAN Configuration : Port3 - VLAN ID
1.3.6.1.4.1.4756.20.441.20.1.744ColumneddPort3VlanTypeRemoteAread-writecurrentEDD Series card Port VLAN Configuration : Port3 - VLAN Type 0: Unaware 1: C-port 2: S-port 3: S-custom-port
1.3.6.1.4.1.4756.20.441.20.1.745ColumneddPort3VlanIngressFilteringRemoteAread-writecurrentEDD Series card Port VLAN Configuration : Port3 - Ingress Filtering 0: Off 1: On
1.3.6.1.4.1.4756.20.441.20.1.746ColumneddPort3VlanIngressAcceptanceRemoteAread-writecurrentEDD Series card Port VLAN Configuration : Port3 - Ingress Acceptance 0: Tagged and untagged 1: Tagged only 2: Untagged only
1.3.6.1.4.1.4756.20.441.20.1.747ColumneddPort3VlanEgressTaggingRemoteAread-writecurrentEDD Series card Port VLAN Configuration : Port3 - Egress Tagging 0: Untag port vlan 1: Tag all 2: Untag all
1.3.6.1.4.1.4756.20.441.20.1.748ColumneddPort3AllowedVLANSRemoteAread-writecurrentEDD Series card Global VLAN Configuration: Port3 - Allowed VLANs By default, only VLAN 1 is enabled. More VLANs may be created by using a list syntax where the…
1.3.6.1.4.1.4756.20.441.20.1.749ColumneddPort3ForbiddenVLANSRemoteAread-writecurrentEDD Series card Global VLAN Configuration: Port3 - Forbidden VLANs By default, the field is left blank, which means that the port may become a member of all po…
1.3.6.1.4.1.4756.20.441.20.1.750ColumneddPort4VlanModeRemoteAread-writecurrentEDD Series card Port VLAN Configuration : Port4 - Mode 0: Access 1: Trunk 2: Hybrid
1.3.6.1.4.1.4756.20.441.20.1.751ColumneddPort4VlanIDRemoteAread-writecurrentEDD Series card Port VLAN Configuration : Port4 - VLAN ID
1.3.6.1.4.1.4756.20.441.20.1.752ColumneddPort4VlanTypeRemoteAread-writecurrentEDD Series card Port VLAN Configuration : Port4 - VLAN Type 0: Unaware 1: C-port 2: S-port 3: S-custom-port
1.3.6.1.4.1.4756.20.441.20.1.753ColumneddPort4VlanIngressFilteringRemoteAread-writecurrentEDD Series card Port VLAN Configuration : Port4 - Ingress Filtering 0: Off 1: On
1.3.6.1.4.1.4756.20.441.20.1.754ColumneddPort4VlanIngressAcceptanceRemoteAread-writecurrentEDD Series card Port VLAN Configuration : Port4 - Ingress Acceptance 0: Tagged and untagged 1: Tagged only 2: Untagged only
1.3.6.1.4.1.4756.20.441.20.1.755ColumneddPort4VlanEgressTaggingRemoteAread-writecurrentEDD Series card Port VLAN Configuration : Port4 - Egress Tagging 0: Untag port vlan 1: Tag all 2: Untag all
1.3.6.1.4.1.4756.20.441.20.1.756ColumneddPort4AllowedVLANSRemoteAread-writecurrentEDD Series card Global VLAN Configuration: Port4 - Allowed VLANs By default, only VLAN 1 is enabled. More VLANs may be created by using a list syntax where the…
1.3.6.1.4.1.4756.20.441.20.1.757ColumneddPort4ForbiddenVLANSRemoteAread-writecurrentEDD Series card Global VLAN Configuration: Port4 - Forbidden VLANs By default, the field is left blank, which means that the port may become a member of all po…
1.3.6.1.4.1.4756.20.441.20.1.758ColumneddDNSServerTypeRemoteAread-writecurrentEDD Series card IP Configuration: This setting controls the DNS name resolution done by the switch. The following modes are supported: 1:From any DHCP interfac…
1.3.6.1.4.1.4756.20.441.20.1.759ColumneddDNSServerSettingRemoteAread-writecurrentEDD Series card IP Configuration: If iDNSServerType setting '3:Configured',this value must setting IP address format as below: Dotted Decimal Notation refers t…
1.3.6.1.4.1.4756.20.441.20.1.760ColumneddDNSproxyRemoteAread-writecurrentEDD Series card IP Configuration: When DNS proxy is enabled, system will relay DNS requests to the currently configured DNS server, and reply as a DNS resolver…
1.3.6.1.4.1.4756.20.441.20.1.761ColumneddAddIPV4InterfaceRemoteAread-writecurrentEDD Series card IP Interfaces: Add a new IP VLAN Interface: Syntax: [<Interface>] [<vlan_list>] [<IPV4_Addr>] [<IPV4_MASK>] Interface : 1~4
1.3.6.1.4.1.4756.20.441.20.1.762ColumneddDeleteInterfaceRemoteAread-writecurrentEDD Series card IP Interfaces: Delete a IPv4/v6 VLAN Interface: Syntax: [<Interface>] Interface: 1~4
1.3.6.1.4.1.4756.20.441.20.1.763ColumneddIPInterface1VLANRemoteAread-onlycurrentEDD Series card IP Interfaces: The VLAN associated with the IP interface. Only ports in this VLAN will be able to access the IP interface. This field is only a…
1.3.6.1.4.1.4756.20.441.20.1.764ColumneddIPInterface1DHCPRemoteAread-writecurrentEDD Series card IP Interfaces: DHCP
1.3.6.1.4.1.4756.20.441.20.1.765ColumneddIPInterface1FallbackRemoteAread-writecurrentEDD Series card IP Interfaces: Fallback
1.3.6.1.4.1.4756.20.441.20.1.766ColumneddIPInterface1IPV4AddressRemoteAread-onlycurrentEDD Series card IP Interfaces: IPV4 Address
1.3.6.1.4.1.4756.20.441.20.1.767ColumneddIPInterface1IPV4MASKLenRemoteAread-onlycurrentEDD Series card IP Interfaces: IPV4 MASK Length
1.3.6.1.4.1.4756.20.441.20.1.768ColumneddIPInterface2VLANRemoteAread-onlycurrentEDD Series card IP Interfaces: The VLAN associated with the IP interface. Only ports in this VLAN will be able to access the IP interface. This field is only a…
1.3.6.1.4.1.4756.20.441.20.1.769ColumneddIPInterface2DHCPRemoteAread-writecurrentEDD Series card IP Interfaces: DHCP
1.3.6.1.4.1.4756.20.441.20.1.770ColumneddIPInterface2FallbackRemoteAread-writecurrentEDD Series card IP Interfaces: Fallback
1.3.6.1.4.1.4756.20.441.20.1.771ColumneddIPInterface2IPV4AddressRemoteAread-onlycurrentEDD Series card IP Interfaces: IPV4 Address
1.3.6.1.4.1.4756.20.441.20.1.772ColumneddIPInterface2IPV4MASKLenRemoteAread-onlycurrentEDD Series card IP Interfaces: IPV4 MASK Length
1.3.6.1.4.1.4756.20.441.20.1.773ColumneddIPInterface3VLANRemoteAread-onlycurrentEDD Series card IP Interfaces: The VLAN associated with the IP interface. Only ports in this VLAN will be able to access the IP interface. This field is only a…
1.3.6.1.4.1.4756.20.441.20.1.774ColumneddIPInterface3DHCPRemoteAread-writecurrentEDD Series card IP Interfaces: DHCP
1.3.6.1.4.1.4756.20.441.20.1.775ColumneddIPInterface3FallbackRemoteAread-writecurrentEDD Series card IP Interfaces: Fallback
1.3.6.1.4.1.4756.20.441.20.1.776ColumneddIPInterface3IPV4AddressRemoteAread-onlycurrentEDD Series card IP Interfaces: IPV4 Address
1.3.6.1.4.1.4756.20.441.20.1.777ColumneddIPInterface3IPV4MASKLenRemoteAread-onlycurrentEDD Series card IP Interfaces: IPV4 MASK Length
1.3.6.1.4.1.4756.20.441.20.1.778ColumneddIPInterface4VLANRemoteAread-onlycurrentEDD Series card IP Interfaces: The VLAN associated with the IP interface. Only ports in this VLAN will be able to access the IP interface. This field is only a…
1.3.6.1.4.1.4756.20.441.20.1.779ColumneddIPInterface4DHCPRemoteAread-writecurrentEDD Series card IP Interfaces: DHCP
1.3.6.1.4.1.4756.20.441.20.1.780ColumneddIPInterface4FallbackRemoteAread-writecurrentEDD Series card IP Interfaces: Fallback
1.3.6.1.4.1.4756.20.441.20.1.781ColumneddIPInterface4IPV4AddressRemoteAread-onlycurrentEDD Series card IP Interfaces: IPV4 Address
1.3.6.1.4.1.4756.20.441.20.1.782ColumneddIPInterface4IPV4MASKLenRemoteAread-onlycurrentEDD Series card IP Interfaces: IPV4 MASK Length
1.3.6.1.4.1.4756.20.441.20.1.783ColumneddAddIPV6InterfaceRemoteAread-writecurrentEDD Series card IP Interfaces: Add a new IPv6 VLAN Interface: Syntax: [<Interface>] [<vlan_list>] [<IPV4_Addr>] [<IPV4_MASK>] Interface : 1~4
1.3.6.1.4.1.4756.20.441.20.1.784ColumneddIPInterface1IPV6AddressRemoteAread-onlycurrentEDD Series card IP Interfaces: IPV6 Address
1.3.6.1.4.1.4756.20.441.20.1.785ColumneddIPInterface1IPV6MASKLenRemoteAread-onlycurrentEDD Series card IP Interfaces: IPV6 MASK Length
1.3.6.1.4.1.4756.20.441.20.1.786ColumneddIPInterface2IPV6AddressRemoteAread-onlycurrentEDD Series card IP Interfaces: IPV6 Address
1.3.6.1.4.1.4756.20.441.20.1.787ColumneddIPInterface2IPV6MASKLenRemoteAread-onlycurrentEDD Series card IP Interfaces: IPV6 MASK Length
1.3.6.1.4.1.4756.20.441.20.1.788ColumneddIPInterface3IPV6AddressRemoteAread-onlycurrentEDD Series card IP Interfaces: IPV6 Address
1.3.6.1.4.1.4756.20.441.20.1.789ColumneddIPInterface3IPV6MASKLenRemoteAread-onlycurrentEDD Series card IP Interfaces: IPV6 MASK Length
1.3.6.1.4.1.4756.20.441.20.1.790ColumneddIPInterface4IPV6AddressRemoteAread-onlycurrentEDD Series card IP Interfaces: IPV6 Address
1.3.6.1.4.1.4756.20.441.20.1.791ColumneddIPInterface4IPV6MASKLenRemoteAread-onlycurrentEDD Series card IP Interfaces: IPV6 MASK Length
1.3.6.1.4.1.4756.20.441.20.1.792ColumneddPort1ALSRemoteAread-writecurrentEDD Series card Port1 auto laser shutdown: 0: Disable 1: Enable
1.3.6.1.4.1.4756.20.441.20.1.793ColumneddPort2ALSRemoteAread-writecurrentEDD Series card Port2 auto laser shutdown: 0: Disable 1: Enable
1.3.6.1.4.1.4756.20.441.20.1.794ColumneddPort3ALSRemoteAread-writecurrentEDD Series card Port3 auto laser shutdown (MX210 only): 0: Disable 1: Enable
1.3.6.1.4.1.4756.20.441.20.1.795ColumneddPort1LLFLogicRemoteAread-writecurrentEDD Series card Port1 link loss forwarding - Logic 0: AND 1: OR
1.3.6.1.4.1.4756.20.441.20.1.796ColumneddPort1LLFLogicPort2RemoteAread-writecurrentEDD Series card Port1 link loss forwarding - Link/Rx Loss Port2 0: NO 1: YES
1.3.6.1.4.1.4756.20.441.20.1.797ColumneddPort1LLFLogicPort3RemoteAread-writecurrentEDD Series card Port1 link loss forwarding - Link/Rx Loss Port3 0: NO 1: YES
1.3.6.1.4.1.4756.20.441.20.1.798ColumneddPort1LLFLogicPort4RemoteAread-writecurrentEDD Series card Port1 link loss forwarding - Link/Rx Loss Port4 0: NO 1: YES
1.3.6.1.4.1.4756.20.441.20.1.799ColumneddPort2LLFLogicRemoteAread-writecurrentEDD Series card Port2 link loss forwarding - Logic 0: AND 1: OR
1.3.6.1.4.1.4756.20.441.20.1.800ColumneddPort2LLFLogicPort1RemoteAread-writecurrentEDD Series card Port2 link loss forwarding - Link/Rx Loss Port1 0: NO 1: YES
1.3.6.1.4.1.4756.20.441.20.1.801ColumneddPort2LLFLogicPort3RemoteAread-writecurrentEDD Series card Port2 link loss forwarding - Link/Rx Loss Port3 0: NO 1: YES
1.3.6.1.4.1.4756.20.441.20.1.802ColumneddPort2LLFLogicPort4RemoteAread-writecurrentEDD Series card Port2 link loss forwarding - Link/Rx Loss Port4 0: NO 1: YES
1.3.6.1.4.1.4756.20.441.20.1.803ColumneddPort3LLFLogicRemoteAread-writecurrentEDD Series card Port1 link loss forwarding - Logic 0: AND 1: OR
1.3.6.1.4.1.4756.20.441.20.1.804ColumneddPort3LLFLogicPort1RemoteAread-writecurrentEDD Series card Port3 link loss forwarding - Link/Rx Loss Port1 0: NO 1: YES
1.3.6.1.4.1.4756.20.441.20.1.805ColumneddPort3LLFLogicPort2RemoteAread-writecurrentEDD Series card Port3 link loss forwarding - Link/Rx Loss Port2 0: NO 1: YES
1.3.6.1.4.1.4756.20.441.20.1.806ColumneddPort3LLFLogicPort4RemoteAread-writecurrentEDD Series card Port3 link loss forwarding - Link/Rx Loss Port4 0: NO 1: YES
1.3.6.1.4.1.4756.20.441.20.1.807ColumneddPort4LLFLogicRemoteAread-writecurrentEDD Series card Port4 link loss forwarding - Logic 0: AND 1: OR
1.3.6.1.4.1.4756.20.441.20.1.808ColumneddPort4LLFLogicPort1RemoteAread-writecurrentEDD Series card Port4 link loss forwarding - Link/Rx Loss Port1 0: NO 1: YES
1.3.6.1.4.1.4756.20.441.20.1.809ColumneddPort4LLFLogicPort2RemoteAread-writecurrentEDD Series card Port4 link loss forwarding - Link/Rx Loss Port2 0: NO 1: YES
1.3.6.1.4.1.4756.20.441.20.1.810ColumneddPort4LLFLogicPort3RemoteAread-writecurrentEDD Series card Port4 link loss forwarding - Link/Rx Loss Port3 0: NO 1: YES
1.3.6.1.4.1.4756.20.441.20.1.811ColumneddQOSPort1IngressRemoteAread-writecurrentEDD Series card QOS Port1 Ingress Enabled 0: NO 1: YES
1.3.6.1.4.1.4756.20.441.20.1.812ColumneddQOSPort1IngressRateRemoteAread-writecurrentEDD Series card QOS Port1 Ingress Rate
1.3.6.1.4.1.4756.20.441.20.1.813ColumneddQOSPort1IngressRateUnitRemoteAread-writecurrentEDD Series card QOS Port1 Ingress Rate Unit 0: Kbps 1: Mbps 2: fps 3: kfps
1.3.6.1.4.1.4756.20.441.20.1.814ColumneddQOSPort1IngressFlowControlRemoteAread-writecurrentEDD Series card QOS Port1 Ingress Flow Control 0: NO 1: YES
1.3.6.1.4.1.4756.20.441.20.1.815ColumneddQOSPort2IngressRemoteAread-writecurrentEDD Series card QOS Port2 Ingress Enabled 0: NO 1: YES
1.3.6.1.4.1.4756.20.441.20.1.816ColumneddQOSPort2IngressRateRemoteAread-writecurrentEDD Series card QOS Port2 Ingress Rate
1.3.6.1.4.1.4756.20.441.20.1.817ColumneddQOSPort2IngressRateUnitRemoteAread-writecurrentEDD Series card QOS Port2 Ingress Rate Unit 0: Kbps 1: Mbps 2: fps 3: kfps
1.3.6.1.4.1.4756.20.441.20.1.818ColumneddQOSPort2IngressFlowControlRemoteAread-writecurrentEDD Series card QOS Port2 Ingress Flow Control 0: NO 1: YES
1.3.6.1.4.1.4756.20.441.20.1.819ColumneddQOSPort3IngressRemoteAread-writecurrentEDD Series card QOS Port3 Ingress Enabled 0: NO 1: YES
1.3.6.1.4.1.4756.20.441.20.1.820ColumneddQOSPort3IngressRateRemoteAread-writecurrentEDD Series card QOS Port3 Ingress Rate
1.3.6.1.4.1.4756.20.441.20.1.821ColumneddQOSPort3IngressRateUnitRemoteAread-writecurrentEDD Series card QOS Port3 Ingress Rate Unit 0: Kbps 1: Mbps 2: fps 3: kfps
1.3.6.1.4.1.4756.20.441.20.1.822ColumneddQOSPort3IngressFlowControlRemoteAread-writecurrentEDD Series card QOS Port3 Ingress Flow Control 0: NO 1: YES
1.3.6.1.4.1.4756.20.441.20.1.823ColumneddQOSPort4IngressRemoteAread-writecurrentEDD Series card QOS Port4 Ingress Enabled 0: NO 1: YES
1.3.6.1.4.1.4756.20.441.20.1.824ColumneddQOSPort4IngressRateRemoteAread-writecurrentEDD Series card QOS Port4 Ingress Rate
1.3.6.1.4.1.4756.20.441.20.1.825ColumneddQOSPort4IngressRateUnitRemoteAread-writecurrentEDD Series card QOS Port4 Ingress Rate Unit 0: Kbps 1: Mbps 2: fps 3: kfps
1.3.6.1.4.1.4756.20.441.20.1.826ColumneddQOSPort4IngressFlowControlRemoteAread-writecurrentEDD Series card QOS Port4 Ingress Flow Control 0: NO 1: YES
1.3.6.1.4.1.4756.20.441.20.1.827ColumneddQOSPort1EgressRemoteAread-writecurrentEDD Series card QOS Port1 Egress Enabled 0: NO 1: YES
1.3.6.1.4.1.4756.20.441.20.1.828ColumneddQOSPort1EgressRateRemoteAread-writecurrentEDD Series card QOS Port1 Egress Rate
1.3.6.1.4.1.4756.20.441.20.1.829ColumneddQOSPort1EgressRateUnitRemoteAread-writecurrentEDD Series card QOS Port1 Egress Rate Unit 0: Kbps 1: Mbps
1.3.6.1.4.1.4756.20.441.20.1.830ColumneddQOSPort2EgressRemoteAread-writecurrentEDD Series card QOS Port2 Egress Enabled 0: NO 1: YES
1.3.6.1.4.1.4756.20.441.20.1.831ColumneddQOSPort2EgressRateRemoteAread-writecurrentEDD Series card QOS Port2 Egress Rate
1.3.6.1.4.1.4756.20.441.20.1.832ColumneddQOSPort2EgressRateUnitRemoteAread-writecurrentEDD Series card QOS Port2 Egress Rate Unit 0: Kbps 1: Mbps
1.3.6.1.4.1.4756.20.441.20.1.833ColumneddQOSPort3EgressRemoteAread-writecurrentEDD Series card QOS Port3 Egress Enabled 0: NO 1: YES
1.3.6.1.4.1.4756.20.441.20.1.834ColumneddQOSPort3EgressRateRemoteAread-writecurrentEDD Series card QOS Port3 Egress Rate
1.3.6.1.4.1.4756.20.441.20.1.835ColumneddQOSPort3EgressRateUnitRemoteAread-writecurrentEDD Series card QOS Port3 Egress Rate Unit 0: Kbps 1: Mbps
1.3.6.1.4.1.4756.20.441.20.1.836ColumneddQOSPort4EgressRemoteAread-writecurrentEDD Series card QOS Port4 Egress Enabled 0: NO 1: YES
1.3.6.1.4.1.4756.20.441.20.1.837ColumneddQOSPort4EgressRateRemoteAread-writecurrentEDD Series card QOS Port4 Egress Rate
1.3.6.1.4.1.4756.20.441.20.1.838ColumneddQOSPort4EgressRateUnitRemoteAread-writecurrentEDD Series card QOS Port4 Egress Rate Unit 0: Kbps 1: Mbps
1.3.6.1.4.1.4756.20.441.20.1.839ColumneddQOSUnicastRemoteAread-writecurrentEDD Series card QOS Storm Control Configuration- Unicast 0: NO 1: YES
1.3.6.1.4.1.4756.20.441.20.1.840ColumneddQOSUnicastRateRemoteAread-writecurrentEDD Series card QOS Storm Control Configuration- Unicast Rate The rate unit is packets per second (pps). 0: 1 1: 2 2: 4 3: 8 4: 16 5: 32 6: 64 7: 128 8: 256 9:…
1.3.6.1.4.1.4756.20.441.20.1.841ColumneddQOSMulticastRemoteAread-writecurrentEDD Series card QOS Storm Control Configuration- Multicast 0: NO 1: YES
1.3.6.1.4.1.4756.20.441.20.1.842ColumneddQOSMulticastRateRemoteAread-writecurrentEDD Series card QOS Storm Control Configuration- Multicast The rate unit is packets per second (pps). 0: 1 1: 2 2: 4 3: 8 4: 16 5: 32 6: 64 7: 128 8: 256 9: 51…
1.3.6.1.4.1.4756.20.441.20.1.843ColumneddQOSBroadcastRemoteAread-writecurrentEDD Series card QOS Storm Control Configuration- Broadcast 0: NO 1: YES
1.3.6.1.4.1.4756.20.441.20.1.844ColumneddQOSBroadcastRateRemoteAread-writecurrentEDD Series card QOS Storm Control Configuration- Broadcast The rate unit is packets per second (pps). 0: 1 1: 2 2: 4 3: 8 4: 16 5: 32 6: 64 7: 128 8: 256 9: 51…
1.3.6.1.4.1.4756.20.441.20.1.845ColumneddL2CPPort1DMAC0180C2000000RemoteAread-writecurrentEDD Series card Port 1 L2CP Mode 0180C2000000 0: Forward 1: Peer
1.3.6.1.4.1.4756.20.441.20.1.846ColumneddL2CPPort1DMAC0180C2000001RemoteAread-writecurrentEDD Series card Port 1 L2CP Mode 0180C2000001 0: Forward 1: Peer
1.3.6.1.4.1.4756.20.441.20.1.847ColumneddL2CPPort1DMAC0180C2000002RemoteAread-writecurrentEDD Series card Port 1 L2CP Mode 0180C2000002 0: Forward 1: Peer
1.3.6.1.4.1.4756.20.441.20.1.848ColumneddL2CPPort1DMAC0180C2000003RemoteAread-writecurrentEDD Series card Port 1 L2CP Mode 0180C2000003 0: Forward 1: Peer
1.3.6.1.4.1.4756.20.441.20.1.849ColumneddL2CPPort1DMAC0180C2000004RemoteAread-writecurrentEDD Series card Port 1 L2CP Mode 0180C2000004 0: Forward 1: Peer
1.3.6.1.4.1.4756.20.441.20.1.850ColumneddL2CPPort1DMAC0180C2000005RemoteAread-writecurrentEDD Series card Port 1 L2CP Mode 0180C2000005 0: Forward 1: Peer
1.3.6.1.4.1.4756.20.441.20.1.851ColumneddL2CPPort1DMAC0180C2000006RemoteAread-writecurrentEDD Series card Port 1 L2CP Mode 0180C2000006 0: Forward 1: Peer
1.3.6.1.4.1.4756.20.441.20.1.852ColumneddL2CPPort1DMAC0180C2000007RemoteAread-writecurrentEDD Series card Port 1 L2CP Mode 0180C2000007 0: Forward 1: Peer
1.3.6.1.4.1.4756.20.441.20.1.853ColumneddL2CPPort1DMAC0180C2000008RemoteAread-writecurrentEDD Series card Port 1 L2CP Mode 0180C2000008 0: Forward 1: Peer
1.3.6.1.4.1.4756.20.441.20.1.854ColumneddL2CPPort1DMAC0180C2000009RemoteAread-writecurrentEDD Series card Port 1 L2CP Mode 0180C2000009 0: Forward 1: Peer
1.3.6.1.4.1.4756.20.441.20.1.855ColumneddL2CPPort1DMAC0180C200000ARemoteAread-writecurrentEDD Series card Port 1 L2CP Mode 0180C200000A 0: Forward 1: Peer
1.3.6.1.4.1.4756.20.441.20.1.856ColumneddL2CPPort1DMAC0180C200000BRemoteAread-writecurrentEDD Series card Port 1 L2CP Mode 0180C200000B 0: Forward 1: Peer
1.3.6.1.4.1.4756.20.441.20.1.857ColumneddL2CPPort1DMAC0180C200000CRemoteAread-writecurrentEDD Series card Port 1 L2CP Mode 0180C200000C 0: Forward 1: Peer
1.3.6.1.4.1.4756.20.441.20.1.858ColumneddL2CPPort1DMAC0180C200000DRemoteAread-writecurrentEDD Series card Port 1 L2CP Mode 0180C200000D 0: Forward 1: Peer
1.3.6.1.4.1.4756.20.441.20.1.859ColumneddL2CPPort1DMAC0180C200000ERemoteAread-writecurrentEDD Series card Port 1 L2CP Mode 0180C200000E 0: Forward 1: Peer
1.3.6.1.4.1.4756.20.441.20.1.860ColumneddL2CPPort1DMAC0180C200000FRemoteAread-writecurrentEDD Series card Port 1 L2CP Mode 0180C200000F 0: Forward 1: Peer
1.3.6.1.4.1.4756.20.441.20.1.861ColumneddL2CPPort1DMAC0180C2000010RemoteAread-writecurrentEDD Series card Port 1 L2CP Mode 0180C2000010 0: Forward 1: Peer
1.3.6.1.4.1.4756.20.441.20.1.862ColumneddL2CPPort1DMAC0180C2000020RemoteAread-writecurrentEDD Series card Port 1 L2CP Mode 0180C2000020 0: Forward 1: Peer
1.3.6.1.4.1.4756.20.441.20.1.863ColumneddL2CPPort1DMAC0180C2000021RemoteAread-writecurrentEDD Series card Port 1 L2CP Mode 0180C2000021 0: Forward 1: Peer
1.3.6.1.4.1.4756.20.441.20.1.864ColumneddL2CPPort1DMAC0180C2000022RemoteAread-writecurrentEDD Series card Port 1 L2CP Mode 0180C2000022 0: Forward 1: Peer
1.3.6.1.4.1.4756.20.441.20.1.865ColumneddL2CPPort1DMAC0180C2000023RemoteAread-writecurrentEDD Series card Port 1 L2CP Mode 0180C2000023 0: Forward 1: Peer
1.3.6.1.4.1.4756.20.441.20.1.866ColumneddL2CPPort1DMAC0180C2000024RemoteAread-writecurrentEDD Series card Port 1 L2CP Mode 0180C2000024 0: Forward 1: Peer
1.3.6.1.4.1.4756.20.441.20.1.867ColumneddL2CPPort1DMAC0180C2000025RemoteAread-writecurrentEDD Series card Port 1 L2CP Mode 0180C2000025 0: Forward 1: Peer
1.3.6.1.4.1.4756.20.441.20.1.868ColumneddL2CPPort1DMAC0180C2000026RemoteAread-writecurrentEDD Series card Port 1 L2CP Mode 0180C2000026 0: Forward 1: Peer
1.3.6.1.4.1.4756.20.441.20.1.869ColumneddL2CPPort1DMAC0180C2000027RemoteAread-writecurrentEDD Series card Port 1 L2CP Mode 0180C2000027 0: Forward 1: Peer
1.3.6.1.4.1.4756.20.441.20.1.870ColumneddL2CPPort1DMAC0180C2000028RemoteAread-writecurrentEDD Series card Port 1 L2CP Mode 0180C2000028 0: Forward 1: Peer
1.3.6.1.4.1.4756.20.441.20.1.871ColumneddL2CPPort1DMAC0180C2000029RemoteAread-writecurrentEDD Series card Port 1 L2CP Mode 0180C2000029 0: Forward 1: Peer
1.3.6.1.4.1.4756.20.441.20.1.872ColumneddL2CPPort1DMAC0180C200002ARemoteAread-writecurrentEDD Series card Port 1 L2CP Mode 0180C200002A 0: Forward 1: Peer
1.3.6.1.4.1.4756.20.441.20.1.873ColumneddL2CPPort1DMAC0180C200002BRemoteAread-writecurrentEDD Series card Port 1 L2CP Mode 0180C200002B 0: Forward 1: Peer
1.3.6.1.4.1.4756.20.441.20.1.874ColumneddL2CPPort1DMAC0180C200002CRemoteAread-writecurrentEDD Series card Port 1 L2CP Mode 0180C200002C 0: Forward 1: Peer
1.3.6.1.4.1.4756.20.441.20.1.875ColumneddL2CPPort1DMAC0180C200002DRemoteAread-writecurrentEDD Series card Port 1 L2CP Mode 0180C200002D 0: Forward 1: Peer
1.3.6.1.4.1.4756.20.441.20.1.876ColumneddL2CPPort1DMAC0180C200002ERemoteAread-writecurrentEDD Series card Port 1 L2CP Mode 0180C200002E 0: Forward 1: Peer
1.3.6.1.4.1.4756.20.441.20.1.877ColumneddL2CPPort1DMAC0180C200002FRemoteAread-writecurrentEDD Series card Port 1 L2CP Mode 0180C200002F 0: Forward 1: Peer
1.3.6.1.4.1.4756.20.441.20.1.878ColumneddL2CPPort2DMAC0180C2000000RemoteAread-writecurrentEDD Series card Port 2 L2CP Mode 0180C2000000 0: Forward 1: Peer
1.3.6.1.4.1.4756.20.441.20.1.879ColumneddL2CPPort2DMAC0180C2000001RemoteAread-writecurrentEDD Series card Port 2 L2CP Mode 0180C2000001 0: Forward 1: Peer
1.3.6.1.4.1.4756.20.441.20.1.880ColumneddL2CPPort2DMAC0180C2000002RemoteAread-writecurrentEDD Series card Port 2 L2CP Mode 0180C2000002 0: Forward 1: Peer
1.3.6.1.4.1.4756.20.441.20.1.881ColumneddL2CPPort2DMAC0180C2000003RemoteAread-writecurrentEDD Series card Port 2 L2CP Mode 0180C2000003 0: Forward 1: Peer
1.3.6.1.4.1.4756.20.441.20.1.882ColumneddL2CPPort2DMAC0180C2000004RemoteAread-writecurrentEDD Series card Port 2 L2CP Mode 0180C2000004 0: Forward 1: Peer
1.3.6.1.4.1.4756.20.441.20.1.883ColumneddL2CPPort2DMAC0180C2000005RemoteAread-writecurrentEDD Series card Port 2 L2CP Mode 0180C2000005 0: Forward 1: Peer
1.3.6.1.4.1.4756.20.441.20.1.884ColumneddL2CPPort2DMAC0180C2000006RemoteAread-writecurrentEDD Series card Port 2 L2CP Mode 0180C2000006 0: Forward 1: Peer
1.3.6.1.4.1.4756.20.441.20.1.885ColumneddL2CPPort2DMAC0180C2000007RemoteAread-writecurrentEDD Series card Port 2 L2CP Mode 0180C2000007 0: Forward 1: Peer
1.3.6.1.4.1.4756.20.441.20.1.886ColumneddL2CPPort2DMAC0180C2000008RemoteAread-writecurrentEDD Series card Port 2 L2CP Mode 0180C2000008 0: Forward 1: Peer
1.3.6.1.4.1.4756.20.441.20.1.887ColumneddL2CPPort2DMAC0180C2000009RemoteAread-writecurrentEDD Series card Port 2 L2CP Mode 0180C2000009 0: Forward 1: Peer
1.3.6.1.4.1.4756.20.441.20.1.888ColumneddL2CPPort2DMAC0180C200000ARemoteAread-writecurrentEDD Series card Port 2 L2CP Mode 0180C200000A 0: Forward 1: Peer
1.3.6.1.4.1.4756.20.441.20.1.889ColumneddL2CPPort2DMAC0180C200000BRemoteAread-writecurrentEDD Series card Port 2 L2CP Mode 0180C200000B 0: Forward 1: Peer
1.3.6.1.4.1.4756.20.441.20.1.890ColumneddL2CPPort2DMAC0180C200000CRemoteAread-writecurrentEDD Series card Port 2 L2CP Mode 0180C200000C 0: Forward 1: Peer
1.3.6.1.4.1.4756.20.441.20.1.891ColumneddL2CPPort2DMAC0180C200000DRemoteAread-writecurrentEDD Series card Port 2 L2CP Mode 0180C200000A 0: Forward 1: Peer
1.3.6.1.4.1.4756.20.441.20.1.892ColumneddL2CPPort2DMAC0180C200000ERemoteAread-writecurrentEDD Series card Port 2 L2CP Mode 0180C200000E 0: Forward 1: Peer
1.3.6.1.4.1.4756.20.441.20.1.893ColumneddL2CPPort2DMAC0180C200000FRemoteAread-writecurrentEDD Series card Port 2 L2CP Mode 0180C200000F 0: Forward 1: Peer
1.3.6.1.4.1.4756.20.441.20.1.894ColumneddL2CPPort2DMAC0180C2000010RemoteAread-writecurrentEDD Series card Port 2 L2CP Mode 0180C2000010 0: Forward 1: Peer
1.3.6.1.4.1.4756.20.441.20.1.895ColumneddL2CPPort2DMAC0180C2000020RemoteAread-writecurrentEDD Series card Port 2 L2CP Mode 0180C2000020 0: Forward 1: Peer
1.3.6.1.4.1.4756.20.441.20.1.896ColumneddL2CPPort2DMAC0180C2000021RemoteAread-writecurrentEDD Series card Port 2 L2CP Mode 0180C2000021 0: Forward 1: Peer
1.3.6.1.4.1.4756.20.441.20.1.897ColumneddL2CPPort2DMAC0180C2000022RemoteAread-writecurrentEDD Series card Port 2 L2CP Mode 0180C2000022 0: Forward 1: Peer
1.3.6.1.4.1.4756.20.441.20.1.898ColumneddL2CPPort2DMAC0180C2000023RemoteAread-writecurrentEDD Series card Port 2 L2CP Mode 0180C2000023 0: Forward 1: Peer
1.3.6.1.4.1.4756.20.441.20.1.899ColumneddL2CPPort2DMAC0180C2000024RemoteAread-writecurrentEDD Series card Port 2 L2CP Mode 0180C2000024 0: Forward 1: Peer
1.3.6.1.4.1.4756.20.441.20.1.900ColumneddL2CPPort2DMAC0180C2000025RemoteAread-writecurrentEDD Series card Port 2 L2CP Mode 0180C2000025 0: Forward 1: Peer
1.3.6.1.4.1.4756.20.441.20.1.901ColumneddL2CPPort2DMAC0180C2000026RemoteAread-writecurrentEDD Series card Port 2 L2CP Mode 0180C2000026 0: Forward 1: Peer
1.3.6.1.4.1.4756.20.441.20.1.902ColumneddL2CPPort2DMAC0180C2000027RemoteAread-writecurrentEDD Series card Port 2 L2CP Mode 0180C2000027 0: Forward 1: Peer
1.3.6.1.4.1.4756.20.441.20.1.903ColumneddL2CPPort2DMAC0180C2000028RemoteAread-writecurrentEDD Series card Port 2 L2CP Mode 0180C2000028 0: Forward 1: Peer
1.3.6.1.4.1.4756.20.441.20.1.904ColumneddL2CPPort2DMAC0180C2000029RemoteAread-writecurrentEDD Series card Port 2 L2CP Mode 0180C2000029 0: Forward 1: Peer
1.3.6.1.4.1.4756.20.441.20.1.905ColumneddL2CPPort2DMAC0180C200002ARemoteAread-writecurrentEDD Series card Port 2 L2CP Mode 0180C200002A 0: Forward 1: Peer
1.3.6.1.4.1.4756.20.441.20.1.906ColumneddL2CPPort2DMAC0180C200002BRemoteAread-writecurrentEDD Series card Port 2 L2CP Mode 0180C200002B 0: Forward 1: Peer
1.3.6.1.4.1.4756.20.441.20.1.907ColumneddL2CPPort2DMAC0180C200002CRemoteAread-writecurrentEDD Series card Port 2 L2CP Mode 0180C200002C 0: Forward 1: Peer
1.3.6.1.4.1.4756.20.441.20.1.908ColumneddL2CPPort2DMAC0180C200002DRemoteAread-writecurrentEDD Series card Port 2 L2CP Mode 0180C200002D 0: Forward 1: Peer
1.3.6.1.4.1.4756.20.441.20.1.909ColumneddL2CPPort2DMAC0180C200002ERemoteAread-writecurrentEDD Series card Port 2 L2CP Mode 0180C200002E 0: Forward 1: Peer
1.3.6.1.4.1.4756.20.441.20.1.910ColumneddL2CPPort2DMAC0180C200002FRemoteAread-writecurrentEDD Series card Port 2 L2CP Mode 0180C200002F 0: Forward 1: Peer
1.3.6.1.4.1.4756.20.441.20.1.911ColumneddL2CPPort3DMAC0180C2000000RemoteAread-writecurrentEDD Series card Port 3 L2CP Mode 0180C2000000 0: Forward 1: Peer
1.3.6.1.4.1.4756.20.441.20.1.912ColumneddL2CPPort3DMAC0180C2000001RemoteAread-writecurrentEDD Series card Port 3 L2CP Mode 0180C2000001 0: Forward 1: Peer
1.3.6.1.4.1.4756.20.441.20.1.913ColumneddL2CPPort3DMAC0180C2000002RemoteAread-writecurrentEDD Series card Port 3 L2CP Mode 0180C2000002 0: Forward 1: Peer
1.3.6.1.4.1.4756.20.441.20.1.914ColumneddL2CPPort3DMAC0180C2000003RemoteAread-writecurrentEDD Series card Port 3 L2CP Mode 0180C2000003 0: Forward 1: Peer
1.3.6.1.4.1.4756.20.441.20.1.915ColumneddL2CPPort3DMAC0180C2000004RemoteAread-writecurrentEDD Series card Port 3 L2CP Mode 0180C2000004 0: Forward 1: Peer
1.3.6.1.4.1.4756.20.441.20.1.916ColumneddL2CPPort3DMAC0180C2000005RemoteAread-writecurrentEDD Series card Port 3 L2CP Mode 0180C2000005 0: Forward 1: Peer
1.3.6.1.4.1.4756.20.441.20.1.917ColumneddL2CPPort3DMAC0180C2000006RemoteAread-writecurrentEDD Series card Port 3 L2CP Mode 0180C2000006 0: Forward 1: Peer
1.3.6.1.4.1.4756.20.441.20.1.918ColumneddL2CPPort3DMAC0180C2000007RemoteAread-writecurrentEDD Series card Port 3 L2CP Mode 0180C2000007 0: Forward 1: Peer
1.3.6.1.4.1.4756.20.441.20.1.919ColumneddL2CPPort3DMAC0180C2000008RemoteAread-writecurrentEDD Series card Port 3 L2CP Mode 0180C2000008 0: Forward 1: Peer
1.3.6.1.4.1.4756.20.441.20.1.920ColumneddL2CPPort3DMAC0180C2000009RemoteAread-writecurrentEDD Series card Port 3 L2CP Mode 0180C2000009 0: Forward 1: Peer
1.3.6.1.4.1.4756.20.441.20.1.921ColumneddL2CPPort3DMAC0180C200000ARemoteAread-writecurrentEDD Series card Port 3 L2CP Mode 0180C200000A 0: Forward 1: Peer
1.3.6.1.4.1.4756.20.441.20.1.922ColumneddL2CPPort3DMAC0180C200000BRemoteAread-writecurrentEDD Series card Port 3 L2CP Mode 0180C200000B 0: Forward 1: Peer
1.3.6.1.4.1.4756.20.441.20.1.923ColumneddL2CPPort3DMAC0180C200000CRemoteAread-writecurrentEDD Series card Port 3 L2CP Mode 0180C200000C 0: Forward 1: Peer
1.3.6.1.4.1.4756.20.441.20.1.924ColumneddL2CPPort3DMAC0180C200000DRemoteAread-writecurrentEDD Series card Port 3 L2CP Mode 0180C200000D 0: Forward 1: Peer
1.3.6.1.4.1.4756.20.441.20.1.925ColumneddL2CPPort3DMAC0180C200000ERemoteAread-writecurrentEDD Series card Port 3 L2CP Mode 0180C200000E 0: Forward 1: Peer
1.3.6.1.4.1.4756.20.441.20.1.926ColumneddL2CPPort3DMAC0180C200000FRemoteAread-writecurrentEDD Series card Port 3 L2CP Mode 0180C200000F 0: Forward 1: Peer
1.3.6.1.4.1.4756.20.441.20.1.927ColumneddL2CPPort3DMAC0180C2000010RemoteAread-writecurrentEDD Series card Port 3 L2CP Mode 0180C2000010 0: Forward 1: Peer
1.3.6.1.4.1.4756.20.441.20.1.928ColumneddL2CPPort3DMAC0180C2000020RemoteAread-writecurrentEDD Series card Port 3 L2CP Mode 0180C2000020 0: Forward 1: Peer
1.3.6.1.4.1.4756.20.441.20.1.929ColumneddL2CPPort3DMAC0180C2000021RemoteAread-writecurrentEDD Series card Port 3 L2CP Mode 0180C2000021 0: Forward 1: Peer
1.3.6.1.4.1.4756.20.441.20.1.930ColumneddL2CPPort3DMAC0180C2000022RemoteAread-writecurrentEDD Series card Port 3 L2CP Mode 0180C2000022 0: Forward 1: Peer
1.3.6.1.4.1.4756.20.441.20.1.931ColumneddL2CPPort3DMAC0180C2000023RemoteAread-writecurrentEDD Series card Port 3 L2CP Mode 0180C2000023 0: Forward 1: Peer
1.3.6.1.4.1.4756.20.441.20.1.932ColumneddL2CPPort3DMAC0180C2000024RemoteAread-writecurrentEDD Series card Port 3 L2CP Mode 0180C2000024 0: Forward 1: Peer
1.3.6.1.4.1.4756.20.441.20.1.933ColumneddL2CPPort3DMAC0180C2000025RemoteAread-writecurrentEDD Series card Port 3 L2CP Mode 0180C2000025 0: Forward 1: Peer
1.3.6.1.4.1.4756.20.441.20.1.934ColumneddL2CPPort3DMAC0180C2000026RemoteAread-writecurrentEDD Series card Port 3 L2CP Mode 0180C2000026 0: Forward 1: Peer
1.3.6.1.4.1.4756.20.441.20.1.935ColumneddL2CPPort3DMAC0180C2000027RemoteAread-writecurrentEDD Series card Port 3 L2CP Mode 0180C2000027 0: Forward 1: Peer
1.3.6.1.4.1.4756.20.441.20.1.936ColumneddL2CPPort3DMAC0180C2000028RemoteAread-writecurrentEDD Series card Port 3 L2CP Mode 0180C2000028 0: Forward 1: Peer
1.3.6.1.4.1.4756.20.441.20.1.937ColumneddL2CPPort3DMAC0180C2000029RemoteAread-writecurrentEDD Series card Port 3 L2CP Mode 0180C2000029 0: Forward 1: Peer
1.3.6.1.4.1.4756.20.441.20.1.938ColumneddL2CPPort3DMAC0180C200002ARemoteAread-writecurrentEDD Series card Port 3 L2CP Mode 0180C200002A 0: Forward 1: Peer
1.3.6.1.4.1.4756.20.441.20.1.939ColumneddL2CPPort3DMAC0180C200002BRemoteAread-writecurrentEDD Series card Port 3 L2CP Mode 0180C200002B 0: Forward 1: Peer
1.3.6.1.4.1.4756.20.441.20.1.940ColumneddL2CPPort3DMAC0180C200002CRemoteAread-writecurrentEDD Series card Port 3 L2CP Mode 0180C200002C 0: Forward 1: Peer
1.3.6.1.4.1.4756.20.441.20.1.941ColumneddL2CPPort3DMAC0180C200002DRemoteAread-writecurrentEDD Series card Port 3 L2CP Mode 0180C200002D 0: Forward 1: Peer
1.3.6.1.4.1.4756.20.441.20.1.942ColumneddL2CPPort3DMAC0180C200002ERemoteAread-writecurrentEDD Series card Port 3 L2CP Mode 0180C200002E 0: Forward 1: Peer
1.3.6.1.4.1.4756.20.441.20.1.943ColumneddL2CPPort3DMAC0180C200002FRemoteAread-writecurrentEDD Series card Port 3 L2CP Mode 0180C200002F 0: Forward 1: Peer
1.3.6.1.4.1.4756.20.441.20.1.944ColumneddL2CPPort4DMAC0180C2000000RemoteAread-writecurrentEDD Series card Port 4 L2CP Mode 0180C2000000 0: Forward 1: Peer
1.3.6.1.4.1.4756.20.441.20.1.945ColumneddL2CPPort4DMAC0180C2000001RemoteAread-writecurrentEDD Series card Port 4 L2CP Mode 0180C2000001 0: Forward 1: Peer
1.3.6.1.4.1.4756.20.441.20.1.946ColumneddL2CPPort4DMAC0180C2000002RemoteAread-writecurrentEDD Series card Port 4 L2CP Mode 0180C2000002 0: Forward 1: Peer
1.3.6.1.4.1.4756.20.441.20.1.947ColumneddL2CPPort4DMAC0180C2000003RemoteAread-writecurrentEDD Series card Port 4 L2CP Mode 0180C2000003 0: Forward 1: Peer
1.3.6.1.4.1.4756.20.441.20.1.948ColumneddL2CPPort4DMAC0180C2000004RemoteAread-writecurrentEDD Series card Port 4 L2CP Mode 0180C2000004 0: Forward 1: Peer
1.3.6.1.4.1.4756.20.441.20.1.949ColumneddL2CPPort4DMAC0180C2000005RemoteAread-writecurrentEDD Series card Port 4 L2CP Mode 0180C2000005 0: Forward 1: Peer
1.3.6.1.4.1.4756.20.441.20.1.950ColumneddL2CPPort4DMAC0180C2000006RemoteAread-writecurrentEDD Series card Port 4 L2CP Mode 0180C2000006 0: Forward 1: Peer
1.3.6.1.4.1.4756.20.441.20.1.951ColumneddL2CPPort4DMAC0180C2000007RemoteAread-writecurrentEDD Series card Port 4 L2CP Mode 0180C2000007 0: Forward 1: Peer
1.3.6.1.4.1.4756.20.441.20.1.952ColumneddL2CPPort4DMAC0180C2000008RemoteAread-writecurrentEDD Series card Port 4 L2CP Mode 0180C2000008 0: Forward 1: Peer
1.3.6.1.4.1.4756.20.441.20.1.953ColumneddL2CPPort4DMAC0180C2000009RemoteAread-writecurrentEDD Series card Port 4 L2CP Mode 0180C2000009 0: Forward 1: Peer
1.3.6.1.4.1.4756.20.441.20.1.954ColumneddL2CPPort4DMAC0180C200000ARemoteAread-writecurrentEDD Series card Port 4 L2CP Mode 0180C200000A 0: Forward 1: Peer
1.3.6.1.4.1.4756.20.441.20.1.955ColumneddL2CPPort4DMAC0180C200000BRemoteAread-writecurrentEDD Series card Port 4 L2CP Mode 0180C200000B 0: Forward 1: Peer
1.3.6.1.4.1.4756.20.441.20.1.956ColumneddL2CPPort4DMAC0180C200000CRemoteAread-writecurrentEDD Series card Port 4 L2CP Mode 0180C200000C 0: Forward 1: Peer
1.3.6.1.4.1.4756.20.441.20.1.957ColumneddL2CPPort4DMAC0180C200000DRemoteAread-writecurrentEDD Series card Port 4 L2CP Mode 0180C200000D 0: Forward 1: Peer
1.3.6.1.4.1.4756.20.441.20.1.958ColumneddL2CPPort4DMAC0180C200000ERemoteAread-writecurrentEDD Series card Port 4 L2CP Mode 0180C200000E 0: Forward 1: Peer
1.3.6.1.4.1.4756.20.441.20.1.959ColumneddL2CPPort4DMAC0180C200000FRemoteAread-writecurrentEDD Series card Port 4 L2CP Mode 0180C200000F 0: Forward 1: Peer
1.3.6.1.4.1.4756.20.441.20.1.960ColumneddL2CPPort4DMAC0180C2000010RemoteAread-writecurrentEDD Series card Port 4 L2CP Mode 0180C2000010 0: Forward 1: Peer
1.3.6.1.4.1.4756.20.441.20.1.961ColumneddL2CPPort4DMAC0180C2000020RemoteAread-writecurrentEDD Series card Port 4 L2CP Mode 0180C2000020 0: Forward 1: Peer
1.3.6.1.4.1.4756.20.441.20.1.962ColumneddL2CPPort4DMAC0180C2000021RemoteAread-writecurrentEDD Series card Port 4 L2CP Mode 0180C2000021 0: Forward 1: Peer
1.3.6.1.4.1.4756.20.441.20.1.963ColumneddL2CPPort4DMAC0180C2000022RemoteAread-writecurrentEDD Series card Port 4 L2CP Mode 0180C2000022 0: Forward 1: Peer
1.3.6.1.4.1.4756.20.441.20.1.964ColumneddL2CPPort4DMAC0180C2000023RemoteAread-writecurrentEDD Series card Port 4 L2CP Mode 0180C2000023 0: Forward 1: Peer
1.3.6.1.4.1.4756.20.441.20.1.965ColumneddL2CPPort4DMAC0180C2000024RemoteAread-writecurrentEDD Series card Port 4 L2CP Mode 0180C2000024 0: Forward 1: Peer
1.3.6.1.4.1.4756.20.441.20.1.966ColumneddL2CPPort4DMAC0180C2000025RemoteAread-writecurrentEDD Series card Port 4 L2CP Mode 0180C2000025 0: Forward 1: Peer
1.3.6.1.4.1.4756.20.441.20.1.967ColumneddL2CPPort4DMAC0180C2000026RemoteAread-writecurrentEDD Series card Port 4 L2CP Mode 0180C2000026 0: Forward 1: Peer
1.3.6.1.4.1.4756.20.441.20.1.968ColumneddL2CPPort4DMAC0180C2000027RemoteAread-writecurrentEDD Series card Port 4 L2CP Mode 0180C2000027 0: Forward 1: Peer
1.3.6.1.4.1.4756.20.441.20.1.969ColumneddL2CPPort4DMAC0180C2000028RemoteAread-writecurrentEDD Series card Port 4 L2CP Mode 0180C2000028 0: Forward 1: Peer
1.3.6.1.4.1.4756.20.441.20.1.970ColumneddL2CPPort4DMAC0180C2000029RemoteAread-writecurrentEDD Series card Port 4 L2CP Mode 0180C2000029 0: Forward 1: Peer
1.3.6.1.4.1.4756.20.441.20.1.971ColumneddL2CPPort4DMAC0180C200002ARemoteAread-writecurrentEDD Series card Port 4 L2CP Mode 0180C200002A 0: Forward 1: Peer
1.3.6.1.4.1.4756.20.441.20.1.972ColumneddL2CPPort4DMAC0180C200002BRemoteAread-writecurrentEDD Series card Port 4 L2CP Mode 0180C200002B 0: Forward 1: Peer
1.3.6.1.4.1.4756.20.441.20.1.973ColumneddL2CPPort4DMAC0180C200002CRemoteAread-writecurrentEDD Series card Port 4 L2CP Mode 0180C200002C 0: Forward 1: Peer
1.3.6.1.4.1.4756.20.441.20.1.974ColumneddL2CPPort4DMAC0180C200002DRemoteAread-writecurrentEDD Series card Port 4 L2CP Mode 0180C200002D 0: Forward 1: Peer
1.3.6.1.4.1.4756.20.441.20.1.975ColumneddL2CPPort4DMAC0180C200002ERemoteAread-writecurrentEDD Series card Port 4 L2CP Mode 0180C200002E 0: Forward 1: Peer
1.3.6.1.4.1.4756.20.441.20.1.976ColumneddL2CPPort4DMAC0180C200002FRemoteAread-writecurrentEDD Series card Port 4 L2CP Mode 0180C200002F 0: Forward 1: Peer
1.3.6.1.4.1.4756.20.441.20.1.977ColumneddPort1MEPInstanceRemoteAread-writecurrentEDD Series card Port 1 MEP Instance 'MEP ID' must be an integer value between 0 and 8191.
1.3.6.1.4.1.4756.20.441.20.1.978ColumneddPort1MEPLogicRemoteAread-writecurrentEDD Series card Port 1 MEP Logic 0: And 1: OR
1.3.6.1.4.1.4756.20.441.20.1.979ColumneddPort2MEPInstanceRemoteAread-writecurrentEDD Series card Port 2 MEP Instance 'MEP ID' must be an integer value between 0 and 8191.
1.3.6.1.4.1.4756.20.441.20.1.980ColumneddPort2MEPLogicRemoteAread-writecurrentEDD Series card Port 2 MEP Logic 0: And 1: OR
1.3.6.1.4.1.4756.20.441.20.1.981ColumneddPort3MEPInstanceRemoteAread-writecurrentEDD Series card Port 3 MEP Instance 'MEP ID' must be an integer value between 0 and 8191.
1.3.6.1.4.1.4756.20.441.20.1.982ColumneddPort3MEPLogicRemoteAread-writecurrentEDD Series card Port 3 MEP Logic 0: And 1: OR
1.3.6.1.4.1.4756.20.441.20.1.983ColumneddPort4MEPInstanceRemoteAread-writecurrentEDD Series card Port 4 MEP Instance 'MEP ID' must be an integer value between 0 and 8191.
1.3.6.1.4.1.4756.20.441.20.1.984ColumneddPort4MEPLogicRemoteAread-writecurrentEDD Series card Port 4 MEP Logic 0: And 1: OR
1.3.6.1.4.1.4756.20.442NodeeddRemoteBCards
1.3.6.1.4.1.4756.20.442.20TableeddRemoteBTablenot-accessiblecurrentA list of RemoteB FRM220-EDD series card entries.
1.3.6.1.4.1.4756.20.442.20.1RoweddRemoteBEntrynot-accessiblecurrentAn entry containing management information applicable to a particular FRM220-EDD series card.
1.3.6.1.4.1.4756.20.442.20.1.1ColumneddChassisIndexRemoteBread-onlycurrentA unique value for each card. It starts from 0 to 9 contiguously.
1.3.6.1.4.1.4756.20.442.20.1.2ColumneddSlotIndexRemoteBread-onlycurrentA unique value for each card. It starts from 1 to 20 contiguously.
1.3.6.1.4.1.4756.20.442.20.1.3ColumneddCardHWVerRemoteBread-onlycurrentEDD Series card hardware version x.xxx
1.3.6.1.4.1.4756.20.442.20.1.4ColumneddCardFWVerRemoteBread-onlycurrentEDD Series card firmware version x.xxx
1.3.6.1.4.1.4756.20.442.20.1.5ColumneddCardCPLDVerRemoteBread-onlycurrentEDD Series card CPLD version x.xxx
1.3.6.1.4.1.4756.20.442.20.1.6ColumneddCardFPGAVerRemoteBread-onlycurrentEDD Series card FPGA version x.xxx
1.3.6.1.4.1.4756.20.442.20.1.7ColumneddModelRemoteBread-onlycurrentCard Type: 0:MX210 1:MSW202
1.3.6.1.4.1.4756.20.442.20.1.8ColumneddPort1LinkstsRemoteBread-onlycurrentEDD Series card Port1 link status: 0:Link down 1:Link up
1.3.6.1.4.1.4756.20.442.20.1.9ColumneddPort1SpeedstsRemoteBread-onlycurrentEDD Series card Port1 speed status 10Base-T 100Base-Tx 1000Base-Tx 2.5G
1.3.6.1.4.1.4756.20.442.20.1.10ColumneddPort1DuplexstsRemoteBread-onlycurrentEDD Series card Port1 duplex status 0: Half 1: Full
1.3.6.1.4.1.4756.20.442.20.1.11ColumneddPort1RxPausestsRemoteBread-onlycurrentEDD Series card Port1 rx pause status 0: No 1: Yes
1.3.6.1.4.1.4756.20.442.20.1.12ColumneddPort1TxPausestsRemoteBread-onlycurrentEDD Series card Port1 tx pause status 0: No 1: Yes
1.3.6.1.4.1.4756.20.442.20.1.13ColumneddPort2LinkstsRemoteBread-onlycurrentEDD Series card Port2 link status: 0:Link down 1:Link up
1.3.6.1.4.1.4756.20.442.20.1.14ColumneddPort2SpeedstsRemoteBread-onlycurrentEDD Series card Port2 speed status 10Base-T 100Base-Tx 1000Base-Tx 2.5G
1.3.6.1.4.1.4756.20.442.20.1.15ColumneddPort2DuplexstsRemoteBread-onlycurrentEDD Series card Port2 duplex status 0: Half 1: Full
1.3.6.1.4.1.4756.20.442.20.1.16ColumneddPort2RxPausestsRemoteBread-onlycurrentEDD Series card Port2 rx pause status 0: No 1: Yes
1.3.6.1.4.1.4756.20.442.20.1.17ColumneddPort2TxPausestsRemoteBread-onlycurrentEDD Series card Port2 tx pause status 0: No 1: Yes
1.3.6.1.4.1.4756.20.442.20.1.18ColumneddPort3LinkstsRemoteBread-onlycurrentEDD Series card Port3 link status: 0:Link down 1:Link up
1.3.6.1.4.1.4756.20.442.20.1.19ColumneddPort3SpeedstsRemoteBread-onlycurrentEDD Series card Port3 speed status 10Base-T 100Base-Tx 1000Base-Tx
1.3.6.1.4.1.4756.20.442.20.1.20ColumneddPort3DuplexstsRemoteBread-onlycurrentEDD Series card Port3 duplex status 0: Half 1: Full
1.3.6.1.4.1.4756.20.442.20.1.21ColumneddPort3RxPausestsRemoteBread-onlycurrentEDD Series card Port3 rx pause status 0: No 1: Yes
1.3.6.1.4.1.4756.20.442.20.1.22ColumneddPort3TxPausestsRemoteBread-onlycurrentEDD Series card Port3 tx pause status 0: No 1: Yes
1.3.6.1.4.1.4756.20.442.20.1.23ColumneddPort4LinkstsRemoteBread-onlycurrentEDD Series card Port4 link status: 0:Link down 1:Link up
1.3.6.1.4.1.4756.20.442.20.1.24ColumneddPort4SpeedstsRemoteBread-onlycurrentEDD Series card Port4 speed status 10Base-T 100Base-Tx 1000Base-Tx
1.3.6.1.4.1.4756.20.442.20.1.25ColumneddPort4DuplexstsRemoteBread-onlycurrentEDD Series card Port4 duplex status 0: Half 1: Full
1.3.6.1.4.1.4756.20.442.20.1.26ColumneddPort4RxPausestsRemoteBread-onlycurrentEDD Series card Port4 rx pause status 0: No 1: Yes
1.3.6.1.4.1.4756.20.442.20.1.27ColumneddPort4TxPausestsRemoteBread-onlycurrentEDD Series card Port4 tx pause status 0: No 1: Yes
1.3.6.1.4.1.4756.20.442.20.1.28ColumneddPort1SpeedConfRemoteBread-writecurrentEDD Series card Port1 speed config 0: disable 1: auto 2: 100M FDX 3: 1G FDX 4: 2.5G FDX
1.3.6.1.4.1.4756.20.442.20.1.29ColumneddPort1flowConrolRemoteBread-writecurrentEDD Series card Port1 flow control config 0: no 1: yes
1.3.6.1.4.1.4756.20.442.20.1.30ColumneddPort1MaxFrameRemoteBread-writecurrentEDD Series card Port1 max frame config
1.3.6.1.4.1.4756.20.442.20.1.31ColumneddPort2SpeedConfRemoteBread-writecurrentEDD Series card Port2 speed config 0: disable 1: auto 2: 100M FDX 3: 1G FDX 4: 2.5G FDX
1.3.6.1.4.1.4756.20.442.20.1.32ColumneddPort2flowConrolRemoteBread-writecurrentEDD Series card Port2 flow control config 0: no 1: yes
1.3.6.1.4.1.4756.20.442.20.1.33ColumneddPort2MaxFrameRemoteBread-writecurrentEDD Series card Port2 max frame config
1.3.6.1.4.1.4756.20.442.20.1.34ColumneddPort3SpeedConfRemoteBread-writecurrentEDD Series card Port3 speed config 0: disable 1: auto 2: 10M HDX 3: 10M FDX 4: 100M HDX 5: 100M FDX 6: 1G FDX
1.3.6.1.4.1.4756.20.442.20.1.35ColumneddPort3flowConrolRemoteBread-writecurrentEDD Series card Port3 flow control config 0: no 1: yes
1.3.6.1.4.1.4756.20.442.20.1.36ColumneddPort3MaxFrameRemoteBread-writecurrentEDD Series card Port3 max frame config
1.3.6.1.4.1.4756.20.442.20.1.37ColumneddPort3CollisionModeRemoteBread-writecurrentEDD Series card Port3 collision mode config.(MSW202 only) 0: Discard 1: Restart
1.3.6.1.4.1.4756.20.442.20.1.38ColumneddPort4SpeedConfRemoteBread-writecurrentEDD Series card Port4 speed config 0: disable 1: auto 2: 10M HDX 3: 10M FDX 4: 100M HDX 5: 100M FDX 6: 1G FDX
1.3.6.1.4.1.4756.20.442.20.1.39ColumneddPort4flowConrolRemoteBread-writecurrentEDD Series card Port4 flow control config 0: no 1: yes
1.3.6.1.4.1.4756.20.442.20.1.40ColumneddPort4MaxFrameRemoteBread-writecurrentEDD Series card Port4 max frame config
1.3.6.1.4.1.4756.20.442.20.1.41ColumneddPort4CollisionModeRemoteBread-writecurrentEDD Series card Port4 collision mode config 0: Discard 1: Restart
1.3.6.1.4.1.4756.20.442.20.1.42ColumneddSaveStartupCongRemoteBread-writecurrentEDD Series card save start-up config 0: OFF 1: Action
1.3.6.1.4.1.4756.20.442.20.1.43ColumneddPortResetRemoteBread-writecurrentEDD Series card port reset 0: OFF 1: Action
1.3.6.1.4.1.4756.20.442.20.1.44ColumneddSetDefaultRemoteBread-writecurrentEDD Series card set to default config 0: OFF 1: Action
1.3.6.1.4.1.4756.20.442.20.1.45ColumneddMuxModeRemoteBread-writecurrentEDD Series card Mux mode (MX210 only) 0: Disable 1: Switch 2: Isolate 3: VLAN
1.3.6.1.4.1.4756.20.442.20.1.46ColumneddPort1PacketsRxRemoteBread-onlycurrentEDD Series card port1 traffic overview:: Packets Rx
1.3.6.1.4.1.4756.20.442.20.1.47ColumneddPort1PacketsTxRemoteBread-onlycurrentEDD Series card port1 traffic overview:: Packets Tx
1.3.6.1.4.1.4756.20.442.20.1.48ColumneddPort1BytesRxRemoteBread-onlycurrentEDD Series card port1 traffic overview:: Bytes Rx
1.3.6.1.4.1.4756.20.442.20.1.49ColumneddPort1BytesTxRemoteBread-onlycurrentEDD Series card port1 traffic overview:: Bytes Tx
1.3.6.1.4.1.4756.20.442.20.1.50ColumneddPort1ErrorsRxRemoteBread-onlycurrentEDD Series card port1 traffic overview:: Errors Rx
1.3.6.1.4.1.4756.20.442.20.1.51ColumneddPort1ErrorsTxRemoteBread-onlycurrentEDD Series card port1 traffic overview:: Errors Tx
1.3.6.1.4.1.4756.20.442.20.1.52ColumneddPort1DropsRxRemoteBread-onlycurrentEDD Series card port1 traffic overview:: Drops Rx
1.3.6.1.4.1.4756.20.442.20.1.53ColumneddPort1DropsTxRemoteBread-onlycurrentEDD Series card port1 traffic overview:: Drops Tx
1.3.6.1.4.1.4756.20.442.20.1.54ColumneddPort1FilteredRxRemoteBread-onlycurrentEDD Series card port1 traffic overview:: Filtered Rx
1.3.6.1.4.1.4756.20.442.20.1.55ColumneddPort2PacketsRxRemoteBread-onlycurrentEDD Series card port2 traffic overview:: Packets Rx
1.3.6.1.4.1.4756.20.442.20.1.56ColumneddPort2PacketsTxRemoteBread-onlycurrentEDD Series card port2 traffic overview:: Packets Tx
1.3.6.1.4.1.4756.20.442.20.1.57ColumneddPort2BytesRxRemoteBread-onlycurrentEDD Series card port2 traffic overview:: Bytes Rx
1.3.6.1.4.1.4756.20.442.20.1.58ColumneddPort2BytesTxRemoteBread-onlycurrentEDD Series card port2 traffic overview:: Bytes Tx
1.3.6.1.4.1.4756.20.442.20.1.59ColumneddPort2ErrorsRxRemoteBread-onlycurrentEDD Series card port2 traffic overview:: Errors Rx
1.3.6.1.4.1.4756.20.442.20.1.60ColumneddPort2ErrorsTxRemoteBread-onlycurrentEDD Series card port2 traffic overview:: Errors Tx
1.3.6.1.4.1.4756.20.442.20.1.61ColumneddPort2DropsRxRemoteBread-onlycurrentEDD Series card port2 traffic overview:: Drops Rx
1.3.6.1.4.1.4756.20.442.20.1.62ColumneddPort2DropsTxRemoteBread-onlycurrentEDD Series card port2 traffic overview:: Drops Tx
1.3.6.1.4.1.4756.20.442.20.1.63ColumneddPort2FilteredRxRemoteBread-onlycurrentEDD Series card port2 traffic overview:: Filtered Rx
1.3.6.1.4.1.4756.20.442.20.1.64ColumneddPort3PacketsRxRemoteBread-onlycurrentEDD Series card port3 traffic overview:: Packets Rx
1.3.6.1.4.1.4756.20.442.20.1.65ColumneddPort3PacketsTxRemoteBread-onlycurrentEDD Series card port3 traffic overview:: Packets Tx
1.3.6.1.4.1.4756.20.442.20.1.66ColumneddPort3BytesRxRemoteBread-onlycurrentEDD Series card port3 traffic overview:: Bytes Rx
1.3.6.1.4.1.4756.20.442.20.1.67ColumneddPort3BytesTxRemoteBread-onlycurrentEDD Series card port3 traffic overview:: Bytes Tx
1.3.6.1.4.1.4756.20.442.20.1.68ColumneddPort3ErrorsRxRemoteBread-onlycurrentEDD Series card port3 traffic overview:: Errors Rx
1.3.6.1.4.1.4756.20.442.20.1.69ColumneddPort3ErrorsTxRemoteBread-onlycurrentEDD Series card port3 traffic overview:: Errors Tx
1.3.6.1.4.1.4756.20.442.20.1.70ColumneddPort3DropsRxRemoteBread-onlycurrentEDD Series card port3 traffic overview:: Drops Rx
1.3.6.1.4.1.4756.20.442.20.1.71ColumneddPort3DropsTxRemoteBread-onlycurrentEDD Series card port3 traffic overview:: Drops Tx
1.3.6.1.4.1.4756.20.442.20.1.72ColumneddPort3FilteredRxRemoteBread-onlycurrentEDD Series card port3 traffic overview:: Filtered Rx
1.3.6.1.4.1.4756.20.442.20.1.73ColumneddPort4PacketsRxRemoteBread-onlycurrentEDD Series card port4 traffic overview:: Packets Rx
1.3.6.1.4.1.4756.20.442.20.1.74ColumneddPort4PacketsTxRemoteBread-onlycurrentEDD Series card port4 traffic overview:: Packets Tx
1.3.6.1.4.1.4756.20.442.20.1.75ColumneddPort4BytesRxRemoteBread-onlycurrentEDD Series card port4 traffic overview:: Bytes Rx
1.3.6.1.4.1.4756.20.442.20.1.76ColumneddPort4BytesTxRemoteBread-onlycurrentEDD Series card port4 traffic overview:: Bytes Tx
1.3.6.1.4.1.4756.20.442.20.1.77ColumneddPort4ErrorsRxRemoteBread-onlycurrentEDD Series card port4 traffic overview:: Errors Rx
1.3.6.1.4.1.4756.20.442.20.1.78ColumneddPort4ErrorsTxRemoteBread-onlycurrentEDD Series card port4 traffic overview:: Errors Tx
1.3.6.1.4.1.4756.20.442.20.1.79ColumneddPort4DropsRxRemoteBread-onlycurrentEDD Series card port4 traffic overview:: Drops Rx
1.3.6.1.4.1.4756.20.442.20.1.80ColumneddPort4DropsTxRemoteBread-onlycurrentEDD Series card port4 traffic overview:: Drops Tx
1.3.6.1.4.1.4756.20.442.20.1.81ColumneddPort4FilteredRxRemoteBread-onlycurrentEDD Series card port4 traffic overview:: Filtered Rx
1.3.6.1.4.1.4756.20.442.20.1.82ColumnedduRingInstanceAddRemoteBread-writecurrentEDD Series card Add a new uRing Instance. Syntax: <Instance ID> <ring|sub|chain> <port east> <port west> Instance ID must be either 1 or 2 port east , the valu…
1.3.6.1.4.1.4756.20.442.20.1.83ColumnedduRingInstanceDeleteRemoteBread-writecurrentEDD Series card Delete a uRing Instance. Syntax: <uRing Instance>
1.3.6.1.4.1.4756.20.442.20.1.84ColumnedduRingInst1IDRemoteBread-onlycurrentEDD Series card u-Ring instance1 ID
1.3.6.1.4.1.4756.20.442.20.1.85ColumnedduRingInst1typeRemoteBread-onlycurrentEDD Series card u-Ring instance1 type 0: u-Ring 1: Sub-Ring 2: u-Chain
1.3.6.1.4.1.4756.20.442.20.1.86ColumnedduRingInst1masterRemoteBread-writecurrentEDD Series card u-Ring instance1 master 0: No 1: Yes
1.3.6.1.4.1.4756.20.442.20.1.87ColumnedduRingInst1EastPortRemoteBread-onlycurrentEDD Series card u-Ring instance1 east port
1.3.6.1.4.1.4756.20.442.20.1.88ColumnedduRingInst1EastEdgeRemoteBread-writecurrentEDD Series card u-Ring instance1 east edge 0: No 1: Yes
1.3.6.1.4.1.4756.20.442.20.1.89ColumnedduRingInst1WestPortRemoteBread-onlycurrentEDD Series card u-Ring instance1 west port
1.3.6.1.4.1.4756.20.442.20.1.90ColumnedduRingInst1WestEdgeRemoteBread-writecurrentEDD Series card u-Ring instance1 west edge 0: No 1: Yes
1.3.6.1.4.1.4756.20.442.20.1.91ColumnedduRingInst2IDRemoteBread-onlycurrentEDD Series card u-Ring instance2 ID
1.3.6.1.4.1.4756.20.442.20.1.92ColumnedduRingInst2typeRemoteBread-onlycurrentEDD Series card u-Ring instance2 type 0: u-Ring 1: Sub-Ring 2: u-Chain
1.3.6.1.4.1.4756.20.442.20.1.93ColumnedduRingInst2masterRemoteBread-writecurrentEDD Series card u-Ring instance2 master 0: No 1: Yes
1.3.6.1.4.1.4756.20.442.20.1.94ColumnedduRingInst2EastPortRemoteBread-onlycurrentEDD Series card u-Ring instance2 east port
1.3.6.1.4.1.4756.20.442.20.1.95ColumnedduRingInst2EastEdgeRemoteBread-writecurrentEDD Series card u-Ring instance2 east edge 0: No 1: Yes
1.3.6.1.4.1.4756.20.442.20.1.96ColumnedduRingInst2WestPortRemoteBread-onlycurrentEDD Series card u-Ring instance2 west port
1.3.6.1.4.1.4756.20.442.20.1.97ColumnedduRingInst2WestEdgeRemoteBread-writecurrentEDD Series card u-Ring instance2 west edge 0: No 1: Yes
1.3.6.1.4.1.4756.20.442.20.1.98ColumnedduRingInst1IDstsRemoteBread-onlycurrentEDD Series card u-Ring Instance1 ID status
1.3.6.1.4.1.4756.20.442.20.1.99ColumnedduRingInst1typestsRemoteBread-onlycurrentEDD Series card u-Ring Type status
1.3.6.1.4.1.4756.20.442.20.1.100ColumnedduRingInst1rolestsRemoteBread-onlycurrentEDD Series card u-Ring Role status
1.3.6.1.4.1.4756.20.442.20.1.101ColumnedduRingInst1EastPortstsRemoteBread-onlycurrentEDD Series card u-Ring East port status
1.3.6.1.4.1.4756.20.442.20.1.102ColumnedduRingInst1EaststsRemoteBread-onlycurrentEDD Series card u-Ring East status
1.3.6.1.4.1.4756.20.442.20.1.103ColumnedduRingInst1EastEdgestsRemoteBread-onlycurrentEDD Series card u-Ring East edge status
1.3.6.1.4.1.4756.20.442.20.1.104ColumnedduRingInst1WestPortstsRemoteBread-onlycurrentEDD Series card u-Ring West edge status
1.3.6.1.4.1.4756.20.442.20.1.105ColumnedduRingInst1WeststsRemoteBread-onlycurrentEDD Series card u-Ring West status
1.3.6.1.4.1.4756.20.442.20.1.106ColumnedduRingInst1WestEdgestsRemoteBread-onlycurrentEDD Series card u-Ring West status
1.3.6.1.4.1.4756.20.442.20.1.107ColumnedduRingInst1healthystsRemoteBread-onlycurrentEDD Series card u-Ring healthy status None Fine Fault
1.3.6.1.4.1.4756.20.442.20.1.108ColumnedduRingInst2IDstsRemoteBread-onlycurrentEDD Series card u-Ring Instance2 ID status
1.3.6.1.4.1.4756.20.442.20.1.109ColumnedduRingInst2typestsRemoteBread-onlycurrentEDD Series card u-Ring Type status
1.3.6.1.4.1.4756.20.442.20.1.110ColumnedduRingInst2rolestsRemoteBread-onlycurrentEDD Series card u-Ring Role status
1.3.6.1.4.1.4756.20.442.20.1.111ColumnedduRingInst2EastPortstsRemoteBread-onlycurrentEDD Series card u-Ring East port status
1.3.6.1.4.1.4756.20.442.20.1.112ColumnedduRingInst2EaststsRemoteBread-onlycurrentEDD Series card u-Ring East status
1.3.6.1.4.1.4756.20.442.20.1.113ColumnedduRingInst2EastEdgestsRemoteBread-onlycurrentEDD Series card u-Ring East edge status
1.3.6.1.4.1.4756.20.442.20.1.114ColumnedduRingInst2WestPortstsRemoteBread-onlycurrentEDD Series card u-Ring West edge status
1.3.6.1.4.1.4756.20.442.20.1.115ColumnedduRingInst2WeststsRemoteBread-onlycurrentEDD Series card u-Ring West status
1.3.6.1.4.1.4756.20.442.20.1.116ColumnedduRingInst2WestEdgestsRemoteBread-onlycurrentEDD Series card u-Ring West status
1.3.6.1.4.1.4756.20.442.20.1.117ColumnedduRingInst2healthystsRemoteBread-onlycurrentEDD Series card u-Ring healthy status None Fine Fault
1.3.6.1.4.1.4756.20.442.20.1.118ColumneddDeviceActiveRemoteBread-onlycurrentEDD Series card u-Ring device active 0: Disable 1: Enable
1.3.6.1.4.1.4756.20.442.20.1.119ColumneddFx1DDRemoteBread-onlycurrentEDD Series card fiber port Digital Diagnostic function: 0:No 1:Yes
1.3.6.1.4.1.4756.20.442.20.1.120ColumneddFx1DDVendorRemoteBread-onlycurrentEDD Series card fiber port D/D information: Vendor name
1.3.6.1.4.1.4756.20.442.20.1.121ColumneddFx1DDPartNoRemoteBread-onlycurrentEDD Series card fiber port D/D information: Vendor part number
1.3.6.1.4.1.4756.20.442.20.1.122ColumneddFx1DDFiberTypeRemoteBread-onlycurrentEDD Series card fiber port D/D information: Fiber Type
1.3.6.1.4.1.4756.20.442.20.1.123ColumneddFx1DDWaveLenRemoteBread-onlycurrentEDD Series card fiber port D/D information: Wave length
1.3.6.1.4.1.4756.20.442.20.1.124ColumneddFx1DDWaveLen2RemoteBread-onlycurrentEDD Series card fiber port D/D information: Wave length 2
1.3.6.1.4.1.4756.20.442.20.1.125ColumneddFx1DDLinkLenRemoteBread-onlycurrentEDD Series card fiber port D/D information: Link length
1.3.6.1.4.1.4756.20.442.20.1.126ColumneddFx1DDLenUnitRemoteBread-onlycurrentEDD Series card fiber port D/D information: Length Unit
1.3.6.1.4.1.4756.20.442.20.1.127ColumneddFx1DDStatusRemoteBread-onlycurrentEDD Series card fiber port D/D information: Status Support
1.3.6.1.4.1.4756.20.442.20.1.128ColumneddFx1DDRxSensRemoteBread-onlycurrentEDD Series card fiber port D/D information: Rx Sensitivity
1.3.6.1.4.1.4756.20.442.20.1.129ColumneddFx1DDTxPWRRemoteBread-onlycurrentEDD Series card fiber port D/D information: Tx power
1.3.6.1.4.1.4756.20.442.20.1.130ColumneddFx1DDRxPWRRemoteBread-onlycurrentEDD Series card fiber port D/D information: Rx power
1.3.6.1.4.1.4756.20.442.20.1.131ColumneddFx1DDTempRemoteBread-onlycurrentEDD Series card fiber port D/D information: Temperature in degree C
1.3.6.1.4.1.4756.20.442.20.1.132ColumneddFx1DDPWRMarginRemoteBread-onlycurrentEDD Series card fiber port D/D information: Power margin
1.3.6.1.4.1.4756.20.442.20.1.133ColumneddFx1DDPWRLossRemoteBread-onlycurrentEDD Series card fiber port D/D information: Power loss
1.3.6.1.4.1.4756.20.442.20.1.134ColumneddFx2DDRemoteBread-onlycurrentEDD Series card fiber2 Digital Diagnostic function: 0:NO 1:Yes
1.3.6.1.4.1.4756.20.442.20.1.135ColumneddFx2DDVendorRemoteBread-onlycurrentEDD Series card fiber2 D/D information: Vendor name
1.3.6.1.4.1.4756.20.442.20.1.136ColumneddFx2DDPartNoRemoteBread-onlycurrentEDD Series card fiber2 D/D information: Vendor part number
1.3.6.1.4.1.4756.20.442.20.1.137ColumneddFx2DDFiberTypeRemoteBread-onlycurrentEDD Series card fiber2 D/D information: Fiber Type
1.3.6.1.4.1.4756.20.442.20.1.138ColumneddFx2DDWaveLenRemoteBread-onlycurrentEDD Series card fiber2 D/D information: Wave length 1
1.3.6.1.4.1.4756.20.442.20.1.139ColumneddFx2DDWaveLen2RemoteBread-onlycurrentEDD Series card fiber2 D/D information: Wave length 2
1.3.6.1.4.1.4756.20.442.20.1.140ColumneddFx2DDLinkLenRemoteBread-onlycurrentEDD Series card fiber2 D/D information: Link length
1.3.6.1.4.1.4756.20.442.20.1.141ColumneddFx2DDLenUnitRemoteBread-onlycurrentEDD Series card fiber2 D/D information: Length Unit
1.3.6.1.4.1.4756.20.442.20.1.142ColumneddFx2DDStatusRemoteBread-onlycurrentEDD Series card fiber2 D/D information: Status Support
1.3.6.1.4.1.4756.20.442.20.1.143ColumneddFx2DDRxSensRemoteBread-onlycurrentEDD Series card fiber2 D/D information: Rx Sensitivity
1.3.6.1.4.1.4756.20.442.20.1.144ColumneddFx2DDTxPWRRemoteBread-onlycurrentEDD Series card fiber2 D/D information: Tx power
1.3.6.1.4.1.4756.20.442.20.1.145ColumneddFx2DDRxPWRRemoteBread-onlycurrentEDD Series card fiber2 D/D information: Rx power
1.3.6.1.4.1.4756.20.442.20.1.146ColumneddFx2DDTempRemoteBread-onlycurrentEDD Series card fiber2 D/D information: Temperature in degree C
1.3.6.1.4.1.4756.20.442.20.1.147ColumneddFx2DDPWRMarginRemoteBread-onlycurrentEDD Series card fiber2 D/D information: Power margin
1.3.6.1.4.1.4756.20.442.20.1.148ColumneddFx2DDPWRLossRemoteBread-onlycurrentEDD Series card fiber2 D/D information: Power loss
1.3.6.1.4.1.4756.20.442.20.1.149ColumneddFx3DDRemoteBread-onlycurrentEDD Series card fiber3 Digital Diagnostic function: 0:NO 1:Yes
1.3.6.1.4.1.4756.20.442.20.1.150ColumneddFx3DDVendorRemoteBread-onlycurrentEDD Series card fiber3 D/D information: Vendor name
1.3.6.1.4.1.4756.20.442.20.1.151ColumneddFx3DDPartNoRemoteBread-onlycurrentEDD Series card fiber32 D/D information: Vendor part number
1.3.6.1.4.1.4756.20.442.20.1.152ColumneddFx3DDFiberTypeRemoteBread-onlycurrentEDD Series card fiber3 D/D information: Fiber Type
1.3.6.1.4.1.4756.20.442.20.1.153ColumneddFx3DDWaveLenRemoteBread-onlycurrentEDD Series card fiber3 D/D information: Wave length 1
1.3.6.1.4.1.4756.20.442.20.1.154ColumneddFx3DDWaveLen2RemoteBread-onlycurrentEDD Series card fiber3 D/D information: Wave length 2
1.3.6.1.4.1.4756.20.442.20.1.155ColumneddFx3DDLinkLenRemoteBread-onlycurrentEDD Series card fiber3 D/D information: Link length
1.3.6.1.4.1.4756.20.442.20.1.156ColumneddFx3DDLenUnitRemoteBread-onlycurrentEDD Series card fiber3 D/D information: Length Unit
1.3.6.1.4.1.4756.20.442.20.1.157ColumneddFx3DDStatusRemoteBread-onlycurrentEDD Series card fiber3 D/D information: Status Support
1.3.6.1.4.1.4756.20.442.20.1.158ColumneddFx3DDRxSensRemoteBread-onlycurrentEDD Series card fiber3 D/D information: Rx Sensitivity
1.3.6.1.4.1.4756.20.442.20.1.159ColumneddFx3DDTxPWRRemoteBread-onlycurrentEDD Series card fiber3 D/D information: Tx power
1.3.6.1.4.1.4756.20.442.20.1.160ColumneddFx3DDRxPWRRemoteBread-onlycurrentEDD Series card fiber3 D/D information: Rx power
1.3.6.1.4.1.4756.20.442.20.1.161ColumneddFx3DDTempRemoteBread-onlycurrentEDD Series card fiber3 D/D information: Temperature in degree C
1.3.6.1.4.1.4756.20.442.20.1.162ColumneddFx3DDPWRMarginRemoteBread-onlycurrentEDD Series card fiber3 D/D information: Power margin
1.3.6.1.4.1.4756.20.442.20.1.163ColumneddFx3DDPWRLossRemoteBread-onlycurrentEDD Series card fiber3 D/D information: Power loss
1.3.6.1.4.1.4756.20.442.20.1.164ColumneddTestRemoteBread-onlycurrentEDD Series card test led sts: 0: Off 1: On
1.3.6.1.4.1.4756.20.442.20.1.165ColumneddClearPortCounterRemoteBread-writecurrentEDD Series card clear port counter: 0: Off 1: Action
1.3.6.1.4.1.4756.20.442.20.1.166ColumneddAggrSourceMACAddrRemoteBread-writecurrentEDD Series card Aggregation Mode Configuration: Source MAC Address 0: No 1: Yes
1.3.6.1.4.1.4756.20.442.20.1.167ColumneddAggrDestinationMACAddrRemoteBread-writecurrentEDD Series card Aggregation Mode Configuration: Destination MAC Address 0: No 1: Yes
1.3.6.1.4.1.4756.20.442.20.1.168ColumneddAggrIPAddrRemoteBread-writecurrentEDD Series card Aggregation Mode Configuration: IP Address 0: No 1: Yes
1.3.6.1.4.1.4756.20.442.20.1.169ColumneddAggrTCPUDPPortNumRemoteBread-writecurrentEDD Series card Aggregation Mode Configuration: TCP/UDP Port Number 0: No 1: Yes
1.3.6.1.4.1.4756.20.442.20.1.170ColumneddAggrGroupPort1ConfRemoteBread-writecurrentEDD Series card Aggregation Group Port1 Configuration: 0: Normal 1: ID1 2: ID2
1.3.6.1.4.1.4756.20.442.20.1.171ColumneddAggrGroupPort2ConfRemoteBread-writecurrentEDD Series card Aggregation Group Port2 Configuration: 0: Normal 1: ID1 2: ID2
1.3.6.1.4.1.4756.20.442.20.1.172ColumneddAggrGroupPort3ConfRemoteBread-writecurrentEDD Series card Aggregation Group Port3 Configuration: 0: Normal 1: ID1 2: ID2
1.3.6.1.4.1.4756.20.442.20.1.173ColumneddAggrGroupPort4ConfRemoteBread-writecurrentEDD Series card Aggregation Group Port4 Configuration: 0: Normal 1: ID1 2: ID2
1.3.6.1.4.1.4756.20.442.20.1.174ColumneddPort1LACPEnabledRemoteBread-writecurrentEDD Series card Port1 LACP Enabled: 0: No 1: Yes
1.3.6.1.4.1.4756.20.442.20.1.175ColumneddPort1LACPKEYRemoteBread-writecurrentEDD Series card Port1 LACP Key value: The Key value incurred by the port, range 0-65535.The value of 0 means auto.
1.3.6.1.4.1.4756.20.442.20.1.176ColumneddPort1LACPRoleRemoteBread-writecurrentEDD Series card Port1 LACP Role: 0: Passive 1: Active
1.3.6.1.4.1.4756.20.442.20.1.177ColumneddPort1LACPTimeOutRemoteBread-writecurrentEDD Series card Port1 LACP Time out: 0: Slow 1: Fast
1.3.6.1.4.1.4756.20.442.20.1.178ColumneddPort1LACPPrioRemoteBread-writecurrentEDD Series card Port1 LACP priority: The Key value incurred by the port, range 1-65535.
1.3.6.1.4.1.4756.20.442.20.1.179ColumneddPort2LACPEnabledRemoteBread-writecurrentEDD Series card Port2 LACP Enabled: 0: No 1: Yes
1.3.6.1.4.1.4756.20.442.20.1.180ColumneddPort2LACPKEYRemoteBread-writecurrentEDD Series card Port2 LACP Key value: The Key value incurred by the port, range 0-65535.The value of 0 means auto.
1.3.6.1.4.1.4756.20.442.20.1.181ColumneddPort2LACPRoleRemoteBread-writecurrentEDD Series card Port2 LACP Role: 0: Passive 1: Active
1.3.6.1.4.1.4756.20.442.20.1.182ColumneddPort2LACPTimeOutRemoteBread-writecurrentEDD Series card Port2 LACP Time out: 0: Slow 1: Fast
1.3.6.1.4.1.4756.20.442.20.1.183ColumneddPort2LACPPrioRemoteBread-writecurrentEDD Series card Port2 LACP priority: The Key value incurred by the port, range 1-65535.
1.3.6.1.4.1.4756.20.442.20.1.184ColumneddPort3LACPEnabledRemoteBread-writecurrentEDD Series card Port3 LACP Enabled: 0: No 1: Yes
1.3.6.1.4.1.4756.20.442.20.1.185ColumneddPort3LACPKEYRemoteBread-writecurrentEDD Series card Port3 LACP Key value: The Key value incurred by the port, range 0-65535.The value of 0 means auto.
1.3.6.1.4.1.4756.20.442.20.1.186ColumneddPort3LACPRoleRemoteBread-writecurrentEDD Series card Port3 LACP Role: 0: Passive 1: Active
1.3.6.1.4.1.4756.20.442.20.1.187ColumneddPort3LACPTimeOutRemoteBread-writecurrentEDD Series card Port3 LACP Time out: 0: Slow 1: Fast
1.3.6.1.4.1.4756.20.442.20.1.188ColumneddPort3LACPPrioRemoteBread-writecurrentEDD Series card Port3 LACP priority: The Key value incurred by the port, range 1-65535.
1.3.6.1.4.1.4756.20.442.20.1.189ColumneddPort4LACPEnabledRemoteBread-writecurrentEDD Series card Port4 LACP Enabled: 0: No 1: Yes
1.3.6.1.4.1.4756.20.442.20.1.190ColumneddPort4LACPKEYRemoteBread-writecurrentEDD Series card Port4 LACP Key value: The Key value incurred by the port, range 0-65535.The value of 0 means auto.
1.3.6.1.4.1.4756.20.442.20.1.191ColumneddPort4LACPRoleRemoteBread-writecurrentEDD Series card Port4 LACP Role: 0: Passive 1: Active
1.3.6.1.4.1.4756.20.442.20.1.192ColumneddPort4LACPTimeOutRemoteBread-writecurrentEDD Series card Port4 LACP Time out: 0: Slow 1: Fast
1.3.6.1.4.1.4756.20.442.20.1.193ColumneddPort4LACPPrioRemoteBread-writecurrentEDD Series card Port4 LACP priority: The Key value incurred by the port, range 1-65535.
1.3.6.1.4.1.4756.20.442.20.1.194ColumneddPort1LACPstsRemoteBread-onlycurrentEDD Series card Port1 LACP status: 0: No 1: Yes 2: Standby
1.3.6.1.4.1.4756.20.442.20.1.195ColumneddPort1LACPKEYstsRemoteBread-onlycurrentEDD Series card Port1 LACP status: Key
1.3.6.1.4.1.4756.20.442.20.1.196ColumneddPort1LACPAggrIDstsRemoteBread-onlycurrentEDD Series card Port1 LACP status: Aggr ID
1.3.6.1.4.1.4756.20.442.20.1.197ColumneddPort1LACPParnterSysIDstsRemoteBread-onlycurrentEDD Series card Port1 LACP status: Parnter System ID
1.3.6.1.4.1.4756.20.442.20.1.198ColumneddPort1LACPParnterPortstsRemoteBread-onlycurrentEDD Series card Port1 LACP status: Parnter Port Status
1.3.6.1.4.1.4756.20.442.20.1.199ColumneddPort1LACPParnterProistsRemoteBread-onlycurrentEDD Series card Port1 LACP status: Parnter Priority
1.3.6.1.4.1.4756.20.442.20.1.200ColumneddPort2LACPstsRemoteBread-onlycurrentEDD Series card Port2 LACP status: 0: No 1: Yes 2: Standby
1.3.6.1.4.1.4756.20.442.20.1.201ColumneddPort2LACPKEYstsRemoteBread-onlycurrentEDD Series card Port2 LACP status: Key
1.3.6.1.4.1.4756.20.442.20.1.202ColumneddPort2LACPAggrIDstsRemoteBread-onlycurrentEDD Series card Port2 LACP status: Aggr ID
1.3.6.1.4.1.4756.20.442.20.1.203ColumneddPort2LACPParnterSysIDstsRemoteBread-onlycurrentEDD Series card Port2 LACP status: Parnter System ID
1.3.6.1.4.1.4756.20.442.20.1.204ColumneddPort2LACPParnterPortstsRemoteBread-onlycurrentEDD Series card Port2 LACP status: Parnter Port Status
1.3.6.1.4.1.4756.20.442.20.1.205ColumneddPort2LACPParnterProistsRemoteBread-onlycurrentEDD Series card Port2 LACP status: Parnter Priority
1.3.6.1.4.1.4756.20.442.20.1.206ColumneddPort3LACPstsRemoteBread-onlycurrentEDD Series card Port3 LACP status: 0: No 1: Yes 2: Standby
1.3.6.1.4.1.4756.20.442.20.1.207ColumneddPort3LACPKEYstsRemoteBread-onlycurrentEDD Series card Port3 LACP status: Key
1.3.6.1.4.1.4756.20.442.20.1.208ColumneddPort3LACPAggrIDstsRemoteBread-onlycurrentEDD Series card Port3 LACP status: Aggr ID
1.3.6.1.4.1.4756.20.442.20.1.209ColumneddPort3LACPParnterSysIDstsRemoteBread-onlycurrentEDD Series card Port3 LACP status: Parnter System ID
1.3.6.1.4.1.4756.20.442.20.1.210ColumneddPort3LACPParnterPortstsRemoteBread-onlycurrentEDD Series card Port3 LACP status: Parnter Port Status
1.3.6.1.4.1.4756.20.442.20.1.211ColumneddPort3LACPParnterProistsRemoteBread-onlycurrentEDD Series card Port3 LACP status: Parnter Priority
1.3.6.1.4.1.4756.20.442.20.1.212ColumneddPort4LACPstsRemoteBread-onlycurrentEDD Series card Port4 LACP status: 0: No 1: Yes 2: Standby
1.3.6.1.4.1.4756.20.442.20.1.213ColumneddPort4LACPKEYstsRemoteBread-onlycurrentEDD Series card Port4 LACP status: Key
1.3.6.1.4.1.4756.20.442.20.1.214ColumneddPort4LACPAggrIDstsRemoteBread-onlycurrentEDD Series card Port4 LACP status: Aggr ID
1.3.6.1.4.1.4756.20.442.20.1.215ColumneddPort4LACPParnterSysIDstsRemoteBread-onlycurrentEDD Series card Port4 LACP status: Parnter System ID
1.3.6.1.4.1.4756.20.442.20.1.216ColumneddPort4LACPParnterPortstsRemoteBread-onlycurrentEDD Series card Port4 LACP status: Parnter Port Status
1.3.6.1.4.1.4756.20.442.20.1.217ColumneddPort4LACPParnterProistsRemoteBread-onlycurrentEDD Series card Port4 LACP status: Parnter Priority
1.3.6.1.4.1.4756.20.442.20.1.218ColumneddOAMPort1EnableRemoteBread-writecurrentEDD Series card Port1 OAM: 0: Off 1: On
1.3.6.1.4.1.4756.20.442.20.1.219ColumneddOAMPort1ModeRemoteBread-writecurrentEDD Series card Port1 OAM: 0: Passive 1: Active
1.3.6.1.4.1.4756.20.442.20.1.220ColumneddOAMPort1LoopBackRemoteBread-writecurrentEDD Series card Port1 OAM LoopBack: 0: Off 1: On
1.3.6.1.4.1.4756.20.442.20.1.221ColumneddOAMPort1LinkMonitorRemoteBread-writecurrentEDD Series card Port1 OAM Link Monitor: 0: Off 1: On
1.3.6.1.4.1.4756.20.442.20.1.222ColumneddOAMPort1MIBRetrievalRemoteBread-writecurrentEDD Series card Port1 OAM MIB Retrieval: 0: Off 1: On
1.3.6.1.4.1.4756.20.442.20.1.223ColumneddOAMPort1LoopBackOPRemoteBread-onlycurrentEDD Series card Port1 OAM LoopBack operation: 0: Off 1: On
1.3.6.1.4.1.4756.20.442.20.1.224ColumneddOAMPort2EnableRemoteBread-writecurrentEDD Series card Port2 OAM: 0: Off 1: On
1.3.6.1.4.1.4756.20.442.20.1.225ColumneddOAMPort2ModeRemoteBread-writecurrentEDD Series card Port2 OAM: 0: Passive 1: Active
1.3.6.1.4.1.4756.20.442.20.1.226ColumneddOAMPort2LoopBackRemoteBread-writecurrentEDD Series card Port2 OAM LoopBack: 0: Off 1: On
1.3.6.1.4.1.4756.20.442.20.1.227ColumneddOAMPort2LinkMonitorRemoteBread-writecurrentEDD Series card Port2 OAM Link Monitor: 0: Off 1: On
1.3.6.1.4.1.4756.20.442.20.1.228ColumneddOAMPort2MIBRetrievalRemoteBread-writecurrentEDD Series card Port2 OAM MIB Retrieval: 0: Off 1: On
1.3.6.1.4.1.4756.20.442.20.1.229ColumneddOAMPort2LoopBackOPRemoteBread-onlycurrentEDD Series card Port2 OAM LoopBack operation: 0: Off 1: On
1.3.6.1.4.1.4756.20.442.20.1.230ColumneddOAMPort3EnableRemoteBread-writecurrentEDD Series card Port3 OAM: 0: Off 1: On
1.3.6.1.4.1.4756.20.442.20.1.231ColumneddOAMPort3ModeRemoteBread-writecurrentEDD Series card Port3 OAM: 0: Passive 1: Active
1.3.6.1.4.1.4756.20.442.20.1.232ColumneddOAMPort3LoopBackRemoteBread-writecurrentEDD Series card Port3 OAM: 0: Off 1: On
1.3.6.1.4.1.4756.20.442.20.1.233ColumneddOAMPort3LinkMonitorRemoteBread-writecurrentEDD Series card Port3 OAM Link Monitor: 0: Off 1: On
1.3.6.1.4.1.4756.20.442.20.1.234ColumneddOAMPort3MIBRetrievalRemoteBread-writecurrentEDD Series card Port3 OAM MIB Retrieval: 0: Off 1: On
1.3.6.1.4.1.4756.20.442.20.1.235ColumneddOAMPort3LoopBackOPRemoteBread-onlycurrentEDD Series card Port3 OAM LoopBack operation: 0: Disable 1: Enable
1.3.6.1.4.1.4756.20.442.20.1.236ColumneddOAMPort4EnableRemoteBread-writecurrentEDD Series card Port4 OAM: 0: Off 1: On
1.3.6.1.4.1.4756.20.442.20.1.237ColumneddOAMPort4ModeRemoteBread-writecurrentEDD Series card Port4 OAM: 0: Passive 1: Active
1.3.6.1.4.1.4756.20.442.20.1.238ColumneddOAMPort4LoopBackRemoteBread-writecurrentEDD Series card Port4 OAM: 0: Off 1: On
1.3.6.1.4.1.4756.20.442.20.1.239ColumneddOAMPort4LinkMonitorRemoteBread-writecurrentEDD Series card Port4 OAM Link Monitor: 0: Off 1: On
1.3.6.1.4.1.4756.20.442.20.1.240ColumneddOAMPort4MIBRetrievalRemoteBread-writecurrentEDD Series card Port4 OAM MIB Retrieval: 0: Off 1: On
1.3.6.1.4.1.4756.20.442.20.1.241ColumneddOAMPort4LoopBackOPRemoteBread-onlycurrentEDD Series card Port4 OAM LoopBack operation: 0: On 1: Off
1.3.6.1.4.1.4756.20.442.20.1.242ColumneddPort1EFEErrorWindowRemoteBread-writecurrentEDD Series card Port1 Link Event Configuration: Error Frame Event - Error Window
1.3.6.1.4.1.4756.20.442.20.1.243ColumneddPort1EFEErrorThresholdRemoteBread-writecurrentEDD Series card Port1 Link Event Configuration: Error Frame Event - Error Threshold
1.3.6.1.4.1.4756.20.442.20.1.244ColumneddPort1SPEEErrorWindowRemoteBread-writecurrentEDD Series card Port1 Link Event Configuration: Symbol Period Error Event - Error Window
1.3.6.1.4.1.4756.20.442.20.1.245ColumneddPort1SPEEErrorThresholdRemoteBread-writecurrentEDD Series card Port1 Link Event Configuration: Symbol Period Error Event - Error Threshold
1.3.6.1.4.1.4756.20.442.20.1.246ColumneddPort1SSEErrorWindowRemoteBread-writecurrentEDD Series card Port1 Link Event Configuration: Seconds Summary Event - Error Window
1.3.6.1.4.1.4756.20.442.20.1.247ColumneddPort1SSEErrorThresholdRemoteBread-writecurrentEDD Series card Port1 Link Event Configuration: Seconds Summary Event - Error Threshold
1.3.6.1.4.1.4756.20.442.20.1.248ColumneddPort2EFEErrorWindowRemoteBread-writecurrentEDD Series card Port2 Link Event Configuration: Error Frame Event - Error Window
1.3.6.1.4.1.4756.20.442.20.1.249ColumneddPort2EFEErrorThresholdRemoteBread-writecurrentEDD Series card Port2 Link Event Configuration: Error Frame Event - Error Threshold
1.3.6.1.4.1.4756.20.442.20.1.250ColumneddPort2SPEEErrorWindowRemoteBread-writecurrentEDD Series card Port2 Link Event Configuration: Symbol Period Error Event - Error Window
1.3.6.1.4.1.4756.20.442.20.1.251ColumneddPort2SPEEErrorThresholdRemoteBread-writecurrentEDD Series card Port2 Link Event Configuration: Symbol Period Error Event - Error Threshold
1.3.6.1.4.1.4756.20.442.20.1.252ColumneddPort2SSEErrorWindowRemoteBread-writecurrentEDD Series card Port2 Link Event Configuration: Seconds Summary Event - Error Window
1.3.6.1.4.1.4756.20.442.20.1.253ColumneddPort2SSEErrorThresholdRemoteBread-writecurrentEDD Series card Port2 Link Event Configuration: Seconds Summary Event - Error Threshold
1.3.6.1.4.1.4756.20.442.20.1.254ColumneddPort3EFEErrorWindowRemoteBread-writecurrentEDD Series card Port3 Link Event Configuration: Error Frame Event - Error Window
1.3.6.1.4.1.4756.20.442.20.1.255ColumneddPort3EFEErrorThresholdRemoteBread-writecurrentEDD Series card Port3 Link Event Configuration: Error Frame Event - Error Threshold
1.3.6.1.4.1.4756.20.442.20.1.256ColumneddPort3SPEEErrorWindowRemoteBread-writecurrentEDD Series card Port3 Link Event Configuration: Symbol Period Error Event - Error Window
1.3.6.1.4.1.4756.20.442.20.1.257ColumneddPort3SPEEErrorThresholdRemoteBread-writecurrentEDD Series card Port3 Link Event Configuration: Symbol Period Error Event - Error Threshold
1.3.6.1.4.1.4756.20.442.20.1.258ColumneddPort3SSEErrorWindowRemoteBread-writecurrentEDD Series card Port3 Link Event Configuration: Seconds Summary Event - Error Window
1.3.6.1.4.1.4756.20.442.20.1.259ColumneddPort3SSEErrorThresholdRemoteBread-writecurrentEDD Series card Port3 Link Event Configuration: Seconds Summary Event - Error Threshold
1.3.6.1.4.1.4756.20.442.20.1.260ColumneddPort4EFEErrorWindowRemoteBread-writecurrentEDD Series card Port4 Link Event Configuration: Error Frame Event - Error Window
1.3.6.1.4.1.4756.20.442.20.1.261ColumneddPort4EFEErrorThresholdRemoteBread-writecurrentEDD Series card Port4 Link Event Configuration: Error Frame Event - Error Threshold
1.3.6.1.4.1.4756.20.442.20.1.262ColumneddPort4SPEEErrorWindowRemoteBread-writecurrentEDD Series card Port4 Link Event Configuration: Symbol Period Error Event - Error Window
1.3.6.1.4.1.4756.20.442.20.1.263ColumneddPort4SPEEErrorThresholdRemoteBread-writecurrentEDD Series card Port4 Link Event Configuration: Symbol Period Error Event - Error Threshold
1.3.6.1.4.1.4756.20.442.20.1.264ColumneddPort4SSEErrorWindowRemoteBread-writecurrentEDD Series card Port4 Link Event Configuration: Seconds Summary Event - Error Window
1.3.6.1.4.1.4756.20.442.20.1.265ColumneddPort4SSEErrorThresholdRemoteBread-writecurrentEDD Series card Port4 Link Event Configuration: Seconds Summary Event - Error Threshold
1.3.6.1.4.1.4756.20.442.20.1.266ColumneddPort1RxOAMInfoPDURemoteBread-onlycurrentEDD Series card Port1 Detailed Link OAM Statistics: Rx OAM Information PDU's
1.3.6.1.4.1.4756.20.442.20.1.267ColumneddPort1RxUniqueErrorEventRemoteBread-onlycurrentEDD Series card Port1 Detailed Link OAM Statistics: Rx Unique Error Event Notificatio
1.3.6.1.4.1.4756.20.442.20.1.268ColumneddPort1RxDuplicateErrorEventRemoteBread-onlycurrentEDD Series card Port1 Detailed Link OAM Statistics: Rx Duplicate Error Event Notification
1.3.6.1.4.1.4756.20.442.20.1.269ColumneddPort1RxLoopBackControlRemoteBread-onlycurrentEDD Series card Port1 Detailed Link OAM Statistics: Rx Loopback Control
1.3.6.1.4.1.4756.20.442.20.1.270ColumneddPort1RxVariableRequestRemoteBread-onlycurrentEDD Series card Port1 Detailed Link OAM Statistics: Rx Variable Request
1.3.6.1.4.1.4756.20.442.20.1.271ColumneddPort1RxVariableResponseRemoteBread-onlycurrentEDD Series card Port1 Detailed Link OAM Statistics: Rx Variable Response
1.3.6.1.4.1.4756.20.442.20.1.272ColumneddPort1RxOrgSpecificPDURemoteBread-onlycurrentEDD Series card Port1 Detailed Link OAM Statistics: Rx Org Specific PDU's
1.3.6.1.4.1.4756.20.442.20.1.273ColumneddPort1RxUnsupportedCodesRemoteBread-onlycurrentEDD Series card Port1 Detailed Link OAM Statistics: Rx Unsupported Codes
1.3.6.1.4.1.4756.20.442.20.1.274ColumneddPort1RxLinkFaultPDURemoteBread-onlycurrentEDD Series card Port1 Detailed Link OAM Statistics: Rx Link Fault PDU's
1.3.6.1.4.1.4756.20.442.20.1.275ColumneddPort1RxDyingGaspRemoteBread-onlycurrentEDD Series card Port1 Detailed Link OAM Statistics: Rx Dying Gasp
1.3.6.1.4.1.4756.20.442.20.1.276ColumneddPort1RxCriticalEventPDURemoteBread-onlycurrentEDD Series card Port1 Detailed Link OAM Statistics: Rx Dying Gasp
1.3.6.1.4.1.4756.20.442.20.1.277ColumneddPort1TxOAMInfoPDURemoteBread-onlycurrentEDD Series card Port1 Detailed Link OAM Statistics: Tx OAM Information PDU's
1.3.6.1.4.1.4756.20.442.20.1.278ColumneddPort1TxUniqueErrorEventRemoteBread-onlycurrentEDD Series card Port1 Detailed Link OAM Statistics: Tx Unique Error Event Notificatio
1.3.6.1.4.1.4756.20.442.20.1.279ColumneddPort1TxDuplicateErrorEventRemoteBread-onlycurrentEDD Series card Port1 Detailed Link OAM Statistics: Tx Duplicate Error Event Notification
1.3.6.1.4.1.4756.20.442.20.1.280ColumneddPort1TxLoopBackControlRemoteBread-onlycurrentEDD Series card Port1 Detailed Link OAM Statistics: Tx Loopback Control
1.3.6.1.4.1.4756.20.442.20.1.281ColumneddPort1TxVariableRequestRemoteBread-onlycurrentEDD Series card Port1 Detailed Link OAM Statistics: Tx Variable Request
1.3.6.1.4.1.4756.20.442.20.1.282ColumneddPort1TxVariableResponseRemoteBread-onlycurrentEDD Series card Port1 Detailed Link OAM Statistics: Tx Variable Response
1.3.6.1.4.1.4756.20.442.20.1.283ColumneddPort1TxOrgSpecificPDURemoteBread-onlycurrentEDD Series card Port1 Detailed Link OAM Statistics: Tx Org Specific PDU's
1.3.6.1.4.1.4756.20.442.20.1.284ColumneddPort1TxUnsupportedCodesRemoteBread-onlycurrentEDD Series card Port1 Detailed Link OAM Statistics: Tx Unsupported Codes
1.3.6.1.4.1.4756.20.442.20.1.285ColumneddPort1TxLinkFaultPDURemoteBread-onlycurrentEDD Series card Port1 Detailed Link OAM Statistics: Tx Link Fault PDU's
1.3.6.1.4.1.4756.20.442.20.1.286ColumneddPort1TxDyingGaspRemoteBread-onlycurrentEDD Series card Port1 Detailed Link OAM Statistics: Tx Dying Gasp
1.3.6.1.4.1.4756.20.442.20.1.287ColumneddPort1TxCriticalEventPDURemoteBread-onlycurrentEDD Series card Port1 Detailed Link OAM Statistics: Tx Dying Gasp
1.3.6.1.4.1.4756.20.442.20.1.288ColumneddPort2RxOAMInfoPDURemoteBread-onlycurrentEDD Series card Port2 Detailed Link OAM Statistics: Rx OAM Information PDU's
1.3.6.1.4.1.4756.20.442.20.1.289ColumneddPort2RxUniqueErrorEventRemoteBread-onlycurrentEDD Series card Port2 Detailed Link OAM Statistics: Rx Unique Error Event Notificatio
1.3.6.1.4.1.4756.20.442.20.1.290ColumneddPort2RxDuplicateErrorEventRemoteBread-onlycurrentEDD Series card Port2 Detailed Link OAM Statistics: Rx Duplicate Error Event Notification
1.3.6.1.4.1.4756.20.442.20.1.291ColumneddPort2RxLoopBackControlRemoteBread-onlycurrentEDD Series card Port2 Detailed Link OAM Statistics: Rx Loopback Control
1.3.6.1.4.1.4756.20.442.20.1.292ColumneddPort2RxVariableRequestRemoteBread-onlycurrentEDD Series card Port2 Detailed Link OAM Statistics: Rx Variable Request
1.3.6.1.4.1.4756.20.442.20.1.293ColumneddPort2RxVariableResponseRemoteBread-onlycurrentEDD Series card Port2 Detailed Link OAM Statistics: Rx Variable Response
1.3.6.1.4.1.4756.20.442.20.1.294ColumneddPort2RxOrgSpecificPDURemoteBread-onlycurrentEDD Series card Port2 Detailed Link OAM Statistics: Rx Org Specific PDU's
1.3.6.1.4.1.4756.20.442.20.1.295ColumneddPort2RxUnsupportedCodesRemoteBread-onlycurrentEDD Series card Port2 Detailed Link OAM Statistics: Rx Unsupported Codes
1.3.6.1.4.1.4756.20.442.20.1.296ColumneddPort2RxLinkFaultPDURemoteBread-onlycurrentEDD Series card Port2 Detailed Link OAM Statistics: Rx Link Fault PDU's
1.3.6.1.4.1.4756.20.442.20.1.297ColumneddPort2RxDyingGaspRemoteBread-onlycurrentEDD Series card Port2 Detailed Link OAM Statistics: Rx Dying Gasp
1.3.6.1.4.1.4756.20.442.20.1.298ColumneddPort2RxCriticalEventPDURemoteBread-onlycurrentEDD Series card Port2 Detailed Link OAM Statistics: Rx Dying Gasp
1.3.6.1.4.1.4756.20.442.20.1.299ColumneddPort2TxOAMInfoPDURemoteBread-onlycurrentEDD Series card Port2 Detailed Link OAM Statistics: Tx OAM Information PDU's
1.3.6.1.4.1.4756.20.442.20.1.300ColumneddPort2TxUniqueErrorEventRemoteBread-onlycurrentEDD Series card Port2 Detailed Link OAM Statistics: Tx Unique Error Event Notificatio
1.3.6.1.4.1.4756.20.442.20.1.301ColumneddPort2TxDuplicateErrorEventRemoteBread-onlycurrentEDD Series card Port2 Detailed Link OAM Statistics: Tx Duplicate Error Event Notification
1.3.6.1.4.1.4756.20.442.20.1.302ColumneddPort2TxLoopBackControlRemoteBread-onlycurrentEDD Series card Port2 Detailed Link OAM Statistics: Tx Loopback Control
1.3.6.1.4.1.4756.20.442.20.1.303ColumneddPort2TxVariableRequestRemoteBread-onlycurrentEDD Series card Port2 Detailed Link OAM Statistics: Tx Variable Request
1.3.6.1.4.1.4756.20.442.20.1.304ColumneddPort2TxVariableResponseRemoteBread-onlycurrentEDD Series card Port2 Detailed Link OAM Statistics: Tx Variable Response
1.3.6.1.4.1.4756.20.442.20.1.305ColumneddPort2TxOrgSpecificPDURemoteBread-onlycurrentEDD Series card Port2 Detailed Link OAM Statistics: Tx Org Specific PDU's
1.3.6.1.4.1.4756.20.442.20.1.306ColumneddPort2TxUnsupportedCodesRemoteBread-onlycurrentEDD Series card Port2 Detailed Link OAM Statistics: Tx Unsupported Codes
1.3.6.1.4.1.4756.20.442.20.1.307ColumneddPort2TxLinkFaultPDURemoteBread-onlycurrentEDD Series card Port2 Detailed Link OAM Statistics: Tx Link Fault PDU's
1.3.6.1.4.1.4756.20.442.20.1.308ColumneddPort2TxDyingGaspRemoteBread-onlycurrentEDD Series card Port2 Detailed Link OAM Statistics: Tx Dying Gasp
1.3.6.1.4.1.4756.20.442.20.1.309ColumneddPort2TxCriticalEventPDURemoteBread-onlycurrentEDD Series card Port2 Detailed Link OAM Statistics: Tx Dying Gasp
1.3.6.1.4.1.4756.20.442.20.1.310ColumneddPort3RxOAMInfoPDURemoteBread-onlycurrentEDD Series card Port3 Detailed Link OAM Statistics: Rx OAM Information PDU's
1.3.6.1.4.1.4756.20.442.20.1.311ColumneddPort3RxUniqueErrorEventRemoteBread-onlycurrentEDD Series card Port3 Detailed Link OAM Statistics: Rx Unique Error Event Notificatio
1.3.6.1.4.1.4756.20.442.20.1.312ColumneddPort3RxDuplicateErrorEventRemoteBread-onlycurrentEDD Series card Port3 Detailed Link OAM Statistics: Rx Duplicate Error Event Notification
1.3.6.1.4.1.4756.20.442.20.1.313ColumneddPort3RxLoopBackControlRemoteBread-onlycurrentEDD Series card Port3 Detailed Link OAM Statistics: Rx Loopback Control
1.3.6.1.4.1.4756.20.442.20.1.314ColumneddPort3RxVariableRequestRemoteBread-onlycurrentEDD Series card Port3 Detailed Link OAM Statistics: Rx Variable Request
1.3.6.1.4.1.4756.20.442.20.1.315ColumneddPort3RxVariableResponseRemoteBread-onlycurrentEDD Series card Port3 Detailed Link OAM Statistics: Rx Variable Response
1.3.6.1.4.1.4756.20.442.20.1.316ColumneddPort3RxOrgSpecificPDURemoteBread-onlycurrentEDD Series card Port3 Detailed Link OAM Statistics: Rx Org Specific PDU's
1.3.6.1.4.1.4756.20.442.20.1.317ColumneddPort3RxUnsupportedCodesRemoteBread-onlycurrentEDD Series card Port3 Detailed Link OAM Statistics: Rx Unsupported Codes
1.3.6.1.4.1.4756.20.442.20.1.318ColumneddPort3RxLinkFaultPDURemoteBread-onlycurrentEDD Series card Port3 Detailed Link OAM Statistics: Rx Link Fault PDU's
1.3.6.1.4.1.4756.20.442.20.1.319ColumneddPort3RxDyingGaspRemoteBread-onlycurrentEDD Series card Port3 Detailed Link OAM Statistics: Rx Dying Gasp
1.3.6.1.4.1.4756.20.442.20.1.320ColumneddPort3RxCriticalEventPDURemoteBread-onlycurrentEDD Series card Port3 Detailed Link OAM Statistics: Rx Dying Gasp
1.3.6.1.4.1.4756.20.442.20.1.321ColumneddPort3TxOAMInfoPDURemoteBread-onlycurrentEDD Series card Port3 Detailed Link OAM Statistics: Tx OAM Information PDU's
1.3.6.1.4.1.4756.20.442.20.1.322ColumneddPort3TxUniqueErrorEventRemoteBread-onlycurrentEDD Series card Port3 Detailed Link OAM Statistics: Tx Unique Error Event Notificatio
1.3.6.1.4.1.4756.20.442.20.1.323ColumneddPort3TxDuplicateErrorEventRemoteBread-onlycurrentEDD Series card Port3 Detailed Link OAM Statistics: Tx Duplicate Error Event Notification
1.3.6.1.4.1.4756.20.442.20.1.324ColumneddPort3TxLoopBackControlRemoteBread-onlycurrentEDD Series card Port3 Detailed Link OAM Statistics: Tx Loopback Control
1.3.6.1.4.1.4756.20.442.20.1.325ColumneddPort3TxVariableRequestRemoteBread-onlycurrentEDD Series card Port3 Detailed Link OAM Statistics: Tx Variable Request
1.3.6.1.4.1.4756.20.442.20.1.326ColumneddPort3TxVariableResponseRemoteBread-onlycurrentEDD Series card Port3 Detailed Link OAM Statistics: Tx Variable Response
1.3.6.1.4.1.4756.20.442.20.1.327ColumneddPort3TxOrgSpecificPDURemoteBread-onlycurrentEDD Series card Port3 Detailed Link OAM Statistics: Tx Org Specific PDU's
1.3.6.1.4.1.4756.20.442.20.1.328ColumneddPort3TxUnsupportedCodesRemoteBread-onlycurrentEDD Series card Port3 Detailed Link OAM Statistics: Tx Unsupported Codes
1.3.6.1.4.1.4756.20.442.20.1.329ColumneddPort3TxLinkFaultPDURemoteBread-onlycurrentEDD Series card Port3 Detailed Link OAM Statistics: Tx Link Fault PDU's
1.3.6.1.4.1.4756.20.442.20.1.330ColumneddPort3TxDyingGaspRemoteBread-onlycurrentEDD Series card Port3 Detailed Link OAM Statistics: Tx Dying Gasp
1.3.6.1.4.1.4756.20.442.20.1.331ColumneddPort3TxCriticalEventPDURemoteBread-onlycurrentEDD Series card Port3 Detailed Link OAM Statistics: Tx Dying Gasp
1.3.6.1.4.1.4756.20.442.20.1.332ColumneddPort4RxOAMInfoPDURemoteBread-onlycurrentEDD Series card Port4 Detailed Link OAM Statistics: Rx OAM Information PDU's
1.3.6.1.4.1.4756.20.442.20.1.333ColumneddPort4RxUniqueErrorEventRemoteBread-onlycurrentEDD Series card Port4 Detailed Link OAM Statistics: Rx Unique Error Event Notificatio
1.3.6.1.4.1.4756.20.442.20.1.334ColumneddPort4RxDuplicateErrorEventRemoteBread-onlycurrentEDD Series card Port4 Detailed Link OAM Statistics: Rx Duplicate Error Event Notification
1.3.6.1.4.1.4756.20.442.20.1.335ColumneddPort4RxLoopBackControlRemoteBread-onlycurrentEDD Series card Port4 Detailed Link OAM Statistics: Rx Loopback Control
1.3.6.1.4.1.4756.20.442.20.1.336ColumneddPort4RxVariableRequestRemoteBread-onlycurrentEDD Series card Port4 Detailed Link OAM Statistics: Rx Variable Request
1.3.6.1.4.1.4756.20.442.20.1.337ColumneddPort4RxVariableResponseRemoteBread-onlycurrentEDD Series card Port4 Detailed Link OAM Statistics: Rx Variable Response
1.3.6.1.4.1.4756.20.442.20.1.338ColumneddPort4RxOrgSpecificPDURemoteBread-onlycurrentEDD Series card Port4 Detailed Link OAM Statistics: Rx Org Specific PDU's
1.3.6.1.4.1.4756.20.442.20.1.339ColumneddPort4RxUnsupportedCodesRemoteBread-onlycurrentEDD Series card Port4 Detailed Link OAM Statistics: Rx Unsupported Codes
1.3.6.1.4.1.4756.20.442.20.1.340ColumneddPort4RxLinkFaultPDURemoteBread-onlycurrentEDD Series card Port4 Detailed Link OAM Statistics: Rx Link Fault PDU's
1.3.6.1.4.1.4756.20.442.20.1.341ColumneddPort4RxDyingGaspRemoteBread-onlycurrentEDD Series card Port4 Detailed Link OAM Statistics: Rx Dying Gasp
1.3.6.1.4.1.4756.20.442.20.1.342ColumneddPort4RxCriticalEventPDURemoteBread-onlycurrentEDD Series card Port4 Detailed Link OAM Statistics: Rx Dying Gasp
1.3.6.1.4.1.4756.20.442.20.1.343ColumneddPort4TxOAMInfoPDURemoteBread-onlycurrentEDD Series card Port4 Detailed Link OAM Statistics: Tx OAM Information PDU's
1.3.6.1.4.1.4756.20.442.20.1.344ColumneddPort4TxUniqueErrorEventRemoteBread-onlycurrentEDD Series card Port4 Detailed Link OAM Statistics: Tx Unique Error Event Notificatio
1.3.6.1.4.1.4756.20.442.20.1.345ColumneddPort4TxDuplicateErrorEventRemoteBread-onlycurrentEDD Series card Port4 Detailed Link OAM Statistics: Tx Duplicate Error Event Notification
1.3.6.1.4.1.4756.20.442.20.1.346ColumneddPort4TxLoopBackControlRemoteBread-onlycurrentEDD Series card Port4 Detailed Link OAM Statistics: Tx Loopback Control
1.3.6.1.4.1.4756.20.442.20.1.347ColumneddPort4TxVariableRequestRemoteBread-onlycurrentEDD Series card Port4 Detailed Link OAM Statistics: Tx Variable Request
1.3.6.1.4.1.4756.20.442.20.1.348ColumneddPort4TxVariableResponseRemoteBread-onlycurrentEDD Series card Port4 Detailed Link OAM Statistics: Tx Variable Response
1.3.6.1.4.1.4756.20.442.20.1.349ColumneddPort4TxOrgSpecificPDURemoteBread-onlycurrentEDD Series card Port4 Detailed Link OAM Statistics: Tx Org Specific PDU's
1.3.6.1.4.1.4756.20.442.20.1.350ColumneddPort4TxUnsupportedCodesRemoteBread-onlycurrentEDD Series card Port4 Detailed Link OAM Statistics: Tx Unsupported Codes
1.3.6.1.4.1.4756.20.442.20.1.351ColumneddPort4TxLinkFaultPDURemoteBread-onlycurrentEDD Series card Port4 Detailed Link OAM Statistics: Tx Link Fault PDU's
1.3.6.1.4.1.4756.20.442.20.1.352ColumneddPort4TxDyingGaspRemoteBread-onlycurrentEDD Series card Port4 Detailed Link OAM Statistics: Tx Dying Gasp
1.3.6.1.4.1.4756.20.442.20.1.353ColumneddPort4TxCriticalEventPDURemoteBread-onlycurrentEDD Series card Port4 Detailed Link OAM Statistics: Tx Dying Gasp
1.3.6.1.4.1.4756.20.442.20.1.354ColumneddPort1PDUPermisionRemoteBread-onlycurrentEDD Series card Detailed Link OAM Status for Port 1: PDU Permission
1.3.6.1.4.1.4756.20.442.20.1.355ColumneddPort1DiscoveryStateRemoteBread-onlycurrentEDD Series card Detailed Link OAM Status for Port 1: Discovery State
1.3.6.1.4.1.4756.20.442.20.1.356ColumneddPort1PeerMACAddrRemoteBread-onlycurrentEDD Series card Detailed Link OAM Status for Port 1: Discovery State
1.3.6.1.4.1.4756.20.442.20.1.357ColumneddPort1LocalModeRemoteBread-onlycurrentEDD Series card Detailed Link OAM Status for Port 1: Local: Mode
1.3.6.1.4.1.4756.20.442.20.1.358ColumneddPort1LocalUnOperationRemoteBread-onlycurrentEDD Series card Detailed Link OAM Status for Port 1: Local: Unidirectional Operation Support
1.3.6.1.4.1.4756.20.442.20.1.359ColumneddPort1LocalRemoteLbRemoteBread-onlycurrentEDD Series card Detailed Link OAM Status for Port 1: Local: Remote Loopback Support
1.3.6.1.4.1.4756.20.442.20.1.360ColumneddPort1LocalLMRemoteBread-onlycurrentEDD Series card Detailed Link OAM Status for Port 1: RemoteB: Link Monitoring Support
1.3.6.1.4.1.4756.20.442.20.1.361ColumneddPort1LocalMIBRetrievalRemoteBread-onlycurrentEDD Series card Detailed Link OAM Status for Port 1: Local: MIB Retrieval Support
1.3.6.1.4.1.4756.20.442.20.1.362ColumneddPort1LocalMTUSizeRemoteBread-onlycurrentEDD Series card Detailed Link OAM Status for Port 1: Local: MTU Size
1.3.6.1.4.1.4756.20.442.20.1.363ColumneddPort1LocalMultiStateRemoteBread-onlycurrentEDD Series card Detailed Link OAM Status for Port 1: Local: Multiplexer State
1.3.6.1.4.1.4756.20.442.20.1.364ColumneddPort1LocalParserStateRemoteBread-onlycurrentEDD Series card Detailed Link OAM Status for Port 1: Local: Multiplexer State
1.3.6.1.4.1.4756.20.442.20.1.365ColumneddPort1LocalOUIRemoteBread-onlycurrentEDD Series card Detailed Link OAM Status for Port 1: Local: Organizational Unique Identification
1.3.6.1.4.1.4756.20.442.20.1.366ColumneddPort1LocalPDURevRemoteBread-onlycurrentEDD Series card Detailed Link OAM Status for Port 1: Local: PDU Revision
1.3.6.1.4.1.4756.20.442.20.1.367ColumneddPort1PeerModeRemoteBread-onlycurrentEDD Series card Detailed Link OAM Status for Port 1: Peer: Mode
1.3.6.1.4.1.4756.20.442.20.1.368ColumneddPort1PeerUnOperationRemoteBread-onlycurrentEDD Series card Detailed Link OAM Status for Port 1: Peer: Unidirectional Operation Support
1.3.6.1.4.1.4756.20.442.20.1.369ColumneddPort1PeerRemoteLbRemoteBread-onlycurrentEDD Series card Detailed Link OAM Status for Port 1: Peer: Remote Loopback Support
1.3.6.1.4.1.4756.20.442.20.1.370ColumneddPort1PeerLMRemoteBread-onlycurrentEDD Series card Detailed Link OAM Status for Port 1: Peer: Link Monitoring Support
1.3.6.1.4.1.4756.20.442.20.1.371ColumneddPort1PeerMIBRetrievalRemoteBread-onlycurrentEDD Series card Detailed Link OAM Status for Port 1: Peer: MIB Retrieval Support
1.3.6.1.4.1.4756.20.442.20.1.372ColumneddPort1PeerMTUSizeRemoteBread-onlycurrentEDD Series card Detailed Link OAM Status for Port 1: Peer: MTU Size
1.3.6.1.4.1.4756.20.442.20.1.373ColumneddPort1PeerMultiStateRemoteBread-onlycurrentEDD Series card Detailed Link OAM Status for Port 1: Peer: Multiplexer State
1.3.6.1.4.1.4756.20.442.20.1.374ColumneddPort1PeerParserStateRemoteBread-onlycurrentEDD Series card Detailed Link OAM Status for Port 1: Peer: Multiplexer State
1.3.6.1.4.1.4756.20.442.20.1.375ColumneddPort1PeerOUIRemoteBread-onlycurrentEDD Series card Detailed Link OAM Status for Port 1: Peer: Organizational Unique Identification
1.3.6.1.4.1.4756.20.442.20.1.376ColumneddPort1PeerPDURevRemoteBread-onlycurrentEDD Series card Detailed Link OAM Status for Port 1: Peer: PDU Revision
1.3.6.1.4.1.4756.20.442.20.1.377ColumneddPort2PDUPermisionRemoteBread-onlycurrentEDD Series card Detailed Link OAM Status for Port 2: PDU Permission
1.3.6.1.4.1.4756.20.442.20.1.378ColumneddPort2DiscoveryStateRemoteBread-onlycurrentEDD Series card Detailed Link OAM Status for Port 2: Discovery State
1.3.6.1.4.1.4756.20.442.20.1.379ColumneddPort2PeerMACAddrRemoteBread-onlycurrentEDD Series card Detailed Link OAM Status for Port 2: Discovery State
1.3.6.1.4.1.4756.20.442.20.1.380ColumneddPort2LocalModeRemoteBread-onlycurrentEDD Series card Detailed Link OAM Status for Port 2: Local: Mode
1.3.6.1.4.1.4756.20.442.20.1.381ColumneddPort2LocalUnOperationRemoteBread-onlycurrentEDD Series card Detailed Link OAM Status for Port 2: Local: Unidirectional Operation Support
1.3.6.1.4.1.4756.20.442.20.1.382ColumneddPort2LocalRemoteLbRemoteBread-onlycurrentEDD Series card Detailed Link OAM Status for Port 2: Local: Remote Loopback Support
1.3.6.1.4.1.4756.20.442.20.1.383ColumneddPort2LocalLMRemoteBread-onlycurrentEDD Series card Detailed Link OAM Status for Port 2: Local: Link Monitoring Support
1.3.6.1.4.1.4756.20.442.20.1.384ColumneddPort2LocalMIBRetrievalRemoteBread-onlycurrentEDD Series card Detailed Link OAM Status for Port 2: Local: MIB Retrieval Support
1.3.6.1.4.1.4756.20.442.20.1.385ColumneddPort2LocalMTUSizeRemoteBread-onlycurrentEDD Series card Detailed Link OAM Status for Port 2: Local: MTU Size
1.3.6.1.4.1.4756.20.442.20.1.386ColumneddPort2LocalMultiStateRemoteBread-onlycurrentEDD Series card Detailed Link OAM Status for Port 2: Local: Multiplexer State
1.3.6.1.4.1.4756.20.442.20.1.387ColumneddPort2LocalParserStateRemoteBread-onlycurrentEDD Series card Detailed Link OAM Status for Port 2: Local: Multiplexer State
1.3.6.1.4.1.4756.20.442.20.1.388ColumneddPort2LocalOUIRemoteBread-onlycurrentEDD Series card Detailed Link OAM Status for Port 2: Local: Organizational Unique Identification
1.3.6.1.4.1.4756.20.442.20.1.389ColumneddPort2LocalPDURevRemoteBread-onlycurrentEDD Series card Detailed Link OAM Status for Port 2: Local: PDU Revision
1.3.6.1.4.1.4756.20.442.20.1.390ColumneddPort2PeerModeRemoteBread-onlycurrentEDD Series card Detailed Link OAM Status for Port 2: Peer: Mode
1.3.6.1.4.1.4756.20.442.20.1.391ColumneddPort2PeerUnOperationRemoteBread-onlycurrentEDD Series card Detailed Link OAM Status for Port 2: Peer: Unidirectional Operation Support
1.3.6.1.4.1.4756.20.442.20.1.392ColumneddPort2PeerRemoteLbRemoteBread-onlycurrentEDD Series card Detailed Link OAM Status for Port 2: Peer: Remote Loopback Support
1.3.6.1.4.1.4756.20.442.20.1.393ColumneddPort2PeerLMRemoteBread-onlycurrentEDD Series card Detailed Link OAM Status for Port 2: Peer: Link Monitoring Support
1.3.6.1.4.1.4756.20.442.20.1.394ColumneddPort2PeerMIBRetrievalRemoteBread-onlycurrentEDD Series card Detailed Link OAM Status for Port 2: Peer: MIB Retrieval Support
1.3.6.1.4.1.4756.20.442.20.1.395ColumneddPort2PeerMTUSizeRemoteBread-onlycurrentEDD Series card Detailed Link OAM Status for Port 2: Peer: MTU Size
1.3.6.1.4.1.4756.20.442.20.1.396ColumneddPort2PeerMultiStateRemoteBread-onlycurrentEDD Series card Detailed Link OAM Status for Port 2: Peer: Multiplexer State
1.3.6.1.4.1.4756.20.442.20.1.397ColumneddPort2PeerParserStateRemoteBread-onlycurrentEDD Series card Detailed Link OAM Status for Port 2: Peer: Multiplexer State
1.3.6.1.4.1.4756.20.442.20.1.398ColumneddPort2PeerOUIRemoteBread-onlycurrentEDD Series card Detailed Link OAM Status for Port 2: Peer: Organizational Unique Identification
1.3.6.1.4.1.4756.20.442.20.1.399ColumneddPort2PeerPDURevRemoteBread-onlycurrentEDD Series card Detailed Link OAM Status for Port 2: Peer: PDU Revision
1.3.6.1.4.1.4756.20.442.20.1.400ColumneddPort3PDUPermisionRemoteBread-onlycurrentEDD Series card Detailed Link OAM Status for Port 3: PDU Permission
1.3.6.1.4.1.4756.20.442.20.1.401ColumneddPort3DiscoveryStateRemoteBread-onlycurrentEDD Series card Detailed Link OAM Status for Port 3: Discovery State
1.3.6.1.4.1.4756.20.442.20.1.402ColumneddPort3PeerMACAddrRemoteBread-onlycurrentEDD Series card Detailed Link OAM Status for Port 3: Discovery State
1.3.6.1.4.1.4756.20.442.20.1.403ColumneddPort3LocalModeRemoteBread-onlycurrentEDD Series card Detailed Link OAM Status for Port 3: Local: Mode
1.3.6.1.4.1.4756.20.442.20.1.404ColumneddPort3LocalUnOperationRemoteBread-onlycurrentEDD Series card Detailed Link OAM Status for Port 3: Local: Unidirectional Operation Support
1.3.6.1.4.1.4756.20.442.20.1.405ColumneddPort3LocalRemoteLbRemoteBread-onlycurrentEDD Series card Detailed Link OAM Status for Port 3: Local: Remote Loopback Support
1.3.6.1.4.1.4756.20.442.20.1.406ColumneddPort3LocalLMRemoteBread-onlycurrentEDD Series card Detailed Link OAM Status for Port 3: Local: Link Monitoring Support
1.3.6.1.4.1.4756.20.442.20.1.407ColumneddPort3LocalMIBRetrievalRemoteBread-onlycurrentEDD Series card Detailed Link OAM Status for Port 3: Local: MIB Retrieval Support
1.3.6.1.4.1.4756.20.442.20.1.408ColumneddPort3LocalMTUSizeRemoteBread-onlycurrentEDD Series card Detailed Link OAM Status for Port 3: Local: MTU Size
1.3.6.1.4.1.4756.20.442.20.1.409ColumneddPort3LocalMultiStateRemoteBread-onlycurrentEDD Series card Detailed Link OAM Status for Port 3: Local: Multiplexer State
1.3.6.1.4.1.4756.20.442.20.1.410ColumneddPort3LocalParserStateRemoteBread-onlycurrentEDD Series card Detailed Link OAM Status for Port 3: Local: Multiplexer State
1.3.6.1.4.1.4756.20.442.20.1.411ColumneddPort3LocalOUIRemoteBread-onlycurrentEDD Series card Detailed Link OAM Status for Port 3: Local: Organizational Unique Identification
1.3.6.1.4.1.4756.20.442.20.1.412ColumneddPort3LocalPDURevRemoteBread-onlycurrentEDD Series card Detailed Link OAM Status for Port 3: Local: PDU Revision
1.3.6.1.4.1.4756.20.442.20.1.413ColumneddPort3PeerModeRemoteBread-onlycurrentEDD Series card Detailed Link OAM Status for Port 3: Peer: Mode
1.3.6.1.4.1.4756.20.442.20.1.414ColumneddPort3PeerUnOperationRemoteBread-onlycurrentEDD Series card Detailed Link OAM Status for Port 3: Peer: Unidirectional Operation Support
1.3.6.1.4.1.4756.20.442.20.1.415ColumneddPort3PeerRemoteLbRemoteBread-onlycurrentEDD Series card Detailed Link OAM Status for Port 3: Peer: Remote Loopback Support
1.3.6.1.4.1.4756.20.442.20.1.416ColumneddPort3PeerLMRemoteBread-onlycurrentEDD Series card Detailed Link OAM Status for Port 3: Peer: Link Monitoring Support
1.3.6.1.4.1.4756.20.442.20.1.417ColumneddPort3PeerMIBRetrievalRemoteBread-onlycurrentEDD Series card Detailed Link OAM Status for Port 3: Peer: MIB Retrieval Support
1.3.6.1.4.1.4756.20.442.20.1.418ColumneddPort3PeerMTUSizeRemoteBread-onlycurrentEDD Series card Detailed Link OAM Status for Port 3: Peer: MTU Size
1.3.6.1.4.1.4756.20.442.20.1.419ColumneddPort3PeerMultiStateRemoteBread-onlycurrentEDD Series card Detailed Link OAM Status for Port 3: Peer: Multiplexer State
1.3.6.1.4.1.4756.20.442.20.1.420ColumneddPort3PeerParserStateRemoteBread-onlycurrentEDD Series card Detailed Link OAM Status for Port 3: Peer: Multiplexer State
1.3.6.1.4.1.4756.20.442.20.1.421ColumneddPort3PeerOUIRemoteBread-onlycurrentEDD Series card Detailed Link OAM Status for Port 3: Peer: Organizational Unique Identification
1.3.6.1.4.1.4756.20.442.20.1.422ColumneddPort3PeerPDURevRemoteBread-onlycurrentEDD Series card Detailed Link OAM Status for Port 3: Peer: PDU Revision
1.3.6.1.4.1.4756.20.442.20.1.423ColumneddPort4PDUPermisionRemoteBread-onlycurrentEDD Series card Detailed Link OAM Status for Port 4: PDU Permission
1.3.6.1.4.1.4756.20.442.20.1.424ColumneddPort4DiscoveryStateRemoteBread-onlycurrentEDD Series card Detailed Link OAM Status for Port 4: Discovery State
1.3.6.1.4.1.4756.20.442.20.1.425ColumneddPort4PeerMACAddrRemoteBread-onlycurrentEDD Series card Detailed Link OAM Status for Port 4: Discovery State
1.3.6.1.4.1.4756.20.442.20.1.426ColumneddPort4LocalModeRemoteBread-onlycurrentEDD Series card Detailed Link OAM Status for Port 4: Local: Mode
1.3.6.1.4.1.4756.20.442.20.1.427ColumneddPort4LocalUnOperationRemoteBread-onlycurrentEDD Series card Detailed Link OAM Status for Port 4: Local: Unidirectional Operation Support
1.3.6.1.4.1.4756.20.442.20.1.428ColumneddPort4LocalRemoteLbRemoteBread-onlycurrentEDD Series card Detailed Link OAM Status for Port 4: Local: Remote Loopback Support
1.3.6.1.4.1.4756.20.442.20.1.429ColumneddPort4LocalLMRemoteBread-onlycurrentEDD Series card Detailed Link OAM Status for Port 4: Local: Link Monitoring Support
1.3.6.1.4.1.4756.20.442.20.1.430ColumneddPort4LocalMIBRetrievalRemoteBread-onlycurrentEDD Series card Detailed Link OAM Status for Port 4: Local: MIB Retrieval Support
1.3.6.1.4.1.4756.20.442.20.1.431ColumneddPort4LocalMTUSizeRemoteBread-onlycurrentEDD Series card Detailed Link OAM Status for Port 4: Local: MTU Size
1.3.6.1.4.1.4756.20.442.20.1.432ColumneddPort4LocalMultiStateRemoteBread-onlycurrentEDD Series card Detailed Link OAM Status for Port 4: Local: Multiplexer State
1.3.6.1.4.1.4756.20.442.20.1.433ColumneddPort4LocalParserStateRemoteBread-onlycurrentEDD Series card Detailed Link OAM Status for Port 4: Local: Multiplexer State
1.3.6.1.4.1.4756.20.442.20.1.434ColumneddPort4LocalOUIRemoteBread-onlycurrentEDD Series card Detailed Link OAM Status for Port 4: Local: Organizational Unique Identification
1.3.6.1.4.1.4756.20.442.20.1.435ColumneddPort4LocalPDURevRemoteBread-onlycurrentEDD Series card Detailed Link OAM Status for Port 4: Local: PDU Revision
1.3.6.1.4.1.4756.20.442.20.1.436ColumneddPort4PeerModeRemoteBread-onlycurrentEDD Series card Detailed Link OAM Status for Port 4: Peer: Mode
1.3.6.1.4.1.4756.20.442.20.1.437ColumneddPort4PeerUnOperationRemoteBread-onlycurrentEDD Series card Detailed Link OAM Status for Port 4: Peer: Unidirectional Operation Support
1.3.6.1.4.1.4756.20.442.20.1.438ColumneddPort4PeerRemoteLbRemoteBread-onlycurrentEDD Series card Detailed Link OAM Status for Port 4: Peer: Remote Loopback Support
1.3.6.1.4.1.4756.20.442.20.1.439ColumneddPort4PeerLMRemoteBread-onlycurrentEDD Series card Detailed Link OAM Status for Port 4: Peer: Link Monitoring Support
1.3.6.1.4.1.4756.20.442.20.1.440ColumneddPort4PeerMIBRetrievalRemoteBread-onlycurrentEDD Series card Detailed Link OAM Status for Port 4: Peer: MIB Retrieval Support
1.3.6.1.4.1.4756.20.442.20.1.441ColumneddPort4PeerMTUSizeRemoteBread-onlycurrentEDD Series card Detailed Link OAM Status for Port 4: Peer: MTU Size
1.3.6.1.4.1.4756.20.442.20.1.442ColumneddPort4PeerMultiStateRemoteBread-onlycurrentEDD Series card Detailed Link OAM Status for Port 4: Peer: Multiplexer State
1.3.6.1.4.1.4756.20.442.20.1.443ColumneddPort4PeerParserStateRemoteBread-onlycurrentEDD Series card Detailed Link OAM Status for Port 4: Peer: Multiplexer State
1.3.6.1.4.1.4756.20.442.20.1.444ColumneddPort4PeerOUIRemoteBread-onlycurrentEDD Series card Detailed Link OAM Status for Port 4: Peer: Organizational Unique Identification
1.3.6.1.4.1.4756.20.442.20.1.445ColumneddPort4PeerPDURevRemoteBread-onlycurrentEDD Series card Detailed Link OAM Status for Port 4: Peer: PDU Revision
1.3.6.1.4.1.4756.20.442.20.1.446ColumneddCLEAROAMCOUNTERRemoteBread-writecurrentEDD Series card Clear OAM Counter: 0: Off 1: Action
1.3.6.1.4.1.4756.20.442.20.1.447ColumneddLoopProtectionEnableRemoteBread-writecurrentEDD Series card Loop Protection Configuration: General Settings - Enable Loop Protection 0: Disable 1: Enable
1.3.6.1.4.1.4756.20.442.20.1.448ColumneddLoopProtectionTxTimeRemoteBread-writecurrentEDD Series card Loop Protection Configuration: General Settings - Transmission Time
1.3.6.1.4.1.4756.20.442.20.1.449ColumneddLoopProtectionShutdownTimeRemoteBread-writecurrentEDD Series card Loop Protection Configuration: General Settings - Shutdown Time
1.3.6.1.4.1.4756.20.442.20.1.450ColumneddLoopProtectionPort1EnabledRemoteBread-writecurrentEDD Series card Loop Protection Configuration for Port 1: Port Configuration - Enable 0: Disable 1: Enable
1.3.6.1.4.1.4756.20.442.20.1.451ColumneddLoopProtectionPort1ActionRemoteBread-writecurrentEDD Series card Loop Protection Configuration for Port 1: Port Configuration - Action 0: Shutdown Port 1: Shutdown Port And Log 2: Log Only
1.3.6.1.4.1.4756.20.442.20.1.452ColumneddLoopProtectionPort1TxModeRemoteBread-writecurrentEDD Series card Loop Protection Configuration for Port 1: Port Configuration - Tx Mode 0: Disable 1: Enable
1.3.6.1.4.1.4756.20.442.20.1.453ColumneddLoopProtectionPort2EnabledRemoteBread-writecurrentEDD Series card Loop Protection Configuration for Port 2: Port Configuration - Enable 0: Disable 1: Enable
1.3.6.1.4.1.4756.20.442.20.1.454ColumneddLoopProtectionPort2ActionRemoteBread-writecurrentEDD Series card Loop Protection Configuration for Port 2: Port Configuration - Action 0: Shutdown Port 1: Shutdown Port And Log 2: Log Only
1.3.6.1.4.1.4756.20.442.20.1.455ColumneddLoopProtectionPort2TxModeRemoteBread-writecurrentEDD Series card Loop Protection Configuration for Port 2: Port Configuration - Tx Mode 0: Disable 1: Enable
1.3.6.1.4.1.4756.20.442.20.1.456ColumneddLoopProtectionPort3EnabledRemoteBread-writecurrentEDD Series card Loop Protection Configuration for Port 3: Port Configuration - Enable 0: Disable 1: Enable
1.3.6.1.4.1.4756.20.442.20.1.457ColumneddLoopProtectionPort3ActionRemoteBread-writecurrentEDD Series card Loop Protection Configuration for Port 3: Port Configuration - Action 0: Shutdown Port 1: Shutdown Port And Log 2: Log Only
1.3.6.1.4.1.4756.20.442.20.1.458ColumneddLoopProtectionPort3TxModeRemoteBread-writecurrentEDD Series card Loop Protection Configuration for Port 3: Port Configuration - Tx Mode 0: Disable 1: Enable
1.3.6.1.4.1.4756.20.442.20.1.459ColumneddLoopProtectionPort4EnabledRemoteBread-writecurrentEDD Series card Loop Protection Configuration for Port 4: Port Configuration - Enable 0: Disable 1: Enable
1.3.6.1.4.1.4756.20.442.20.1.460ColumneddLoopProtectionPort4ActionRemoteBread-writecurrentEDD Series card Loop Protection Configuration for Port 4: Port Configuration - Action 0: Shutdown Port 1: Shutdown Port And Log 2: Log Only
1.3.6.1.4.1.4756.20.442.20.1.461ColumneddLoopProtectionPort4TxModeRemoteBread-writecurrentEDD Series card Loop Protection Configuration for Port 41: Port Configuration - Tx Mode 0: Disable 1: Enable
1.3.6.1.4.1.4756.20.442.20.1.462ColumneddLoopProtectionPort1ActionStsRemoteBread-onlycurrentEDD Series card Loop Protection Status for Port 1: Action
1.3.6.1.4.1.4756.20.442.20.1.463ColumneddLoopProtectionPort1TransStsRemoteBread-onlycurrentEDD Series card Loop Protection Status for Port 1: Transmit
1.3.6.1.4.1.4756.20.442.20.1.464ColumneddLoopProtectionPort1LoopsStsRemoteBread-onlycurrentEDD Series card Loop Protection Status for Port 1: Loops
1.3.6.1.4.1.4756.20.442.20.1.465ColumneddLoopProtectionPort1StatusRemoteBread-onlycurrentEDD Series card Loop Protection Status for Port 1: Status
1.3.6.1.4.1.4756.20.442.20.1.466ColumneddLoopProtectionPort1LoopStsRemoteBread-onlycurrentEDD Series card Loop Protection Status for Port 1: Loop
1.3.6.1.4.1.4756.20.442.20.1.467ColumneddLoopProtectionPort1TimeOfLastLoopRemoteBread-onlycurrentEDD Series card Loop Protection Status for Port 1: Time of Last Loop
1.3.6.1.4.1.4756.20.442.20.1.468ColumneddLoopProtectionPort2ActionStsRemoteBread-onlycurrentEDD Series card Loop Protection Status for Port 2: Action
1.3.6.1.4.1.4756.20.442.20.1.469ColumneddLoopProtectionPort2TransStsRemoteBread-onlycurrentEDD Series card Loop Protection Status for Port 2: Transmit
1.3.6.1.4.1.4756.20.442.20.1.470ColumneddLoopProtectionPort2LoopsStsRemoteBread-onlycurrentEDD Series card Loop Protection Status for Port 2: Loops
1.3.6.1.4.1.4756.20.442.20.1.471ColumneddLoopProtectionPort2StatusRemoteBread-onlycurrentEDD Series card Loop Protection Status for Port 2: Status
1.3.6.1.4.1.4756.20.442.20.1.472ColumneddLoopProtectionPort2LoopStsRemoteBread-onlycurrentEDD Series card Loop Protection Status for Port 2: Loop
1.3.6.1.4.1.4756.20.442.20.1.473ColumneddLoopProtectionPort2TimeOfLastLoopRemoteBread-onlycurrentEDD Series card Loop Protection Status for Port 2: Time of Last Loop
1.3.6.1.4.1.4756.20.442.20.1.474ColumneddLoopProtectionPort3ActionStsRemoteBread-onlycurrentEDD Series card Loop Protection Status for Port 3: Action
1.3.6.1.4.1.4756.20.442.20.1.475ColumneddLoopProtectionPort3TransStsRemoteBread-onlycurrentEDD Series card Loop Protection Status for Port 3: Transmit
1.3.6.1.4.1.4756.20.442.20.1.476ColumneddLoopProtectionPort3LoopsStsRemoteBread-onlycurrentEDD Series card Loop Protection Status for Port 3: Loops
1.3.6.1.4.1.4756.20.442.20.1.477ColumneddLoopProtectionPort3StatusRemoteBread-onlycurrentEDD Series card Loop Protection Status for Port 3: Status
1.3.6.1.4.1.4756.20.442.20.1.478ColumneddLoopProtectionPort3LoopStsRemoteBread-onlycurrentEDD Series card Loop Protection Status for Port 3: Loop
1.3.6.1.4.1.4756.20.442.20.1.479ColumneddLoopProtectionPort3TimeOfLastLoopRemoteBread-onlycurrentEDD Series card Loop Protection Status for Port 3: Time of Last Loop
1.3.6.1.4.1.4756.20.442.20.1.480ColumneddLoopProtectionPort4ActionStsRemoteBread-onlycurrentEDD Series card Loop Protection Status for Port 4: Action
1.3.6.1.4.1.4756.20.442.20.1.481ColumneddLoopProtectionPort4TransStsRemoteBread-onlycurrentEDD Series card Loop Protection Status for Port 4: Transmit
1.3.6.1.4.1.4756.20.442.20.1.482ColumneddLoopProtectionPort4LoopsStsRemoteBread-onlycurrentEDD Series card Loop Protection Status for Port 4: Loops
1.3.6.1.4.1.4756.20.442.20.1.483ColumneddLoopProtectionPort4StatusRemoteBread-onlycurrentEDD Series card Loop Protection Status for Port 4: Status
1.3.6.1.4.1.4756.20.442.20.1.484ColumneddLoopProtectionPort4LoopStsRemoteBread-onlycurrentEDD Series card Loop Protection Status for Port 4: Loop
1.3.6.1.4.1.4756.20.442.20.1.485ColumneddLoopProtectionPort4TimeOfLastLoopRemoteBread-onlycurrentEDD Series card Loop Protection Status for Port 4: Time of Last Loop
1.3.6.1.4.1.4756.20.442.20.1.486ColumneddSTPProtocolVersionRemoteBread-writecurrentEDD Series card STP Bridge Configuration: Basic Settings - Protocol Version 0: STP 1: RSTP 2: MSTP
1.3.6.1.4.1.4756.20.442.20.1.487ColumneddSTPBridgePriorityRemoteBread-writecurrentEDD Series card STP Bridge Configuration: Basic Settings - Bridge Priority 0: 0 1: 4096 2: 8192 3: 12288 4: 16384 5: 20480 6: 24576 7: 28672 8: 32768 9: 36864 …
1.3.6.1.4.1.4756.20.442.20.1.488ColumneddSTPForwardDelayRemoteBread-writecurrentEDD Series card STP Bridge Configuration: Basic Settings - Forward Delay
1.3.6.1.4.1.4756.20.442.20.1.489ColumneddSTPMaxAgeRemoteBread-writecurrentEDD Series card STP Bridge Configuration: Basic Settings - Max Age
1.3.6.1.4.1.4756.20.442.20.1.490ColumneddSTPMaximumHopCountRemoteBread-writecurrentEDD Series card STP Bridge Configuration: Basic Settings - Maximum Hop Count
1.3.6.1.4.1.4756.20.442.20.1.491ColumneddSTPTransmitHoldCountRemoteBread-writecurrentEDD Series card STP Bridge Configuration: Basic Settings - Transmit Hold Count
1.3.6.1.4.1.4756.20.442.20.1.492ColumneddSTPEdgePortBPDUFilteringRemoteBread-writecurrentEDD Series card STP Bridge Configuration: Advanced Settings - Edge Port BPDU Filtering 0: Off 1: On
1.3.6.1.4.1.4756.20.442.20.1.493ColumneddSTPEdgePortBPDUGuardRemoteBread-writecurrentEDD Series card STP Bridge Configuration: Advanced Settings - Edge Port BPDU Guard 0: Off 1: On
1.3.6.1.4.1.4756.20.442.20.1.494ColumneddSTPPortErrorRecoveryTimeoutRemoteBread-writecurrentEDD Series card STP Bridge Configuration: Advanced Settings - Port Error Recovery Timeout 0: Off 1: On
1.3.6.1.4.1.4756.20.442.20.1.495ColumneddMSTIConfigurationNameRemoteBread-writecurrentEDD Series card MSTI Configuration: Configuration Identification - Configuration Name
1.3.6.1.4.1.4756.20.442.20.1.496ColumneddMSTIConfigurationRevisionRemoteBread-writecurrentEDD Series card MSTI Configuration: Configuration Identification - Configuration Revision
1.3.6.1.4.1.4756.20.442.20.1.497ColumneddMSTI1VLANsMappingRemoteBread-writecurrentEDD Series card MSTI Configuration: MSTI Mapping - MSTI 1
1.3.6.1.4.1.4756.20.442.20.1.498ColumneddMSTI2VLANsMappingRemoteBread-writecurrentEDD Series card MSTI Configuration: MSTI Mapping - MSTI 2
1.3.6.1.4.1.4756.20.442.20.1.499ColumneddMSTI3VLANsMappingRemoteBread-writecurrentEDD Series card MSTI Configuration: MSTI Mapping - MSTI 3
1.3.6.1.4.1.4756.20.442.20.1.500ColumneddMSTI4VLANsMappingRemoteBread-writecurrentEDD Series card MSTI Configuration: MSTI Mapping - MSTI 4
1.3.6.1.4.1.4756.20.442.20.1.501ColumneddMSTI5VLANsMappingRemoteBread-writecurrentEDD Series card MSTI Configuration: MSTI Mapping - MSTI 5
1.3.6.1.4.1.4756.20.442.20.1.502ColumneddMSTI6VLANsMappingRemoteBread-writecurrentEDD Series card MSTI Configuration: MSTI Mapping - MSTI 6
1.3.6.1.4.1.4756.20.442.20.1.503ColumneddMSTI7VLANsMappingRemoteBread-writecurrentEDD Series card MSTI Configuration: MSTI Mapping - MSTI 7
1.3.6.1.4.1.4756.20.442.20.1.504ColumneddCISTAggregatedSTPEnabledRemoteBread-writecurrentEDD Series card STP CIST Port Configuration: CIST Aggregated Port Configuration - STP Enabled
1.3.6.1.4.1.4756.20.442.20.1.505ColumneddCISTAggregatedPathCostRemoteBread-writecurrentEDD Series card STP CIST Port Configuration: CIST Aggregated Port Configuration - Path Cost Valid values are in the range 0 to 200000000. Setting 0 means Auto …
1.3.6.1.4.1.4756.20.442.20.1.506ColumneddCISTAggregatedPriorityRemoteBread-writecurrentEDD Series card STP CIST Port Configuration: CIST Aggregated Port Configuration - Priority
1.3.6.1.4.1.4756.20.442.20.1.507ColumneddCISTAggregatedAdminEdgeRemoteBread-writecurrentEDD Series card STP CIST Port Configuration: CIST Aggregated Port Configuration - STP Enabled 0: Non-edge 1: Edge
1.3.6.1.4.1.4756.20.442.20.1.508ColumneddCISTAggregatedAutoEdgeRemoteBread-writecurrentEDD Series card STP CIST Port Configuration: CIST Aggregated Port Configuration - Auto Edge 0: Non-edge 1: Edge
1.3.6.1.4.1.4756.20.442.20.1.509ColumneddCISTAggregatedRestrictedRoleRemoteBread-writecurrentEDD Series card STP CIST Port Configuration: CIST Aggregated Port Configuration - Restricted Role 0: Non-edge 1: Edge
1.3.6.1.4.1.4756.20.442.20.1.510ColumneddCISTAggregatedRestrictedTCNRemoteBread-writecurrentEDD Series card STP CIST Port Configuration: CIST Aggregated Port Configuration - Restricted TCN 0: Non-edge 1: Edge
1.3.6.1.4.1.4756.20.442.20.1.511ColumneddCISTAggregatedBPDUGuardRemoteBread-writecurrentEDD Series card STP CIST Port Configuration: CIST Aggregated Port Configuration - BPDU Guard 0: Non-edge 1: Edge
1.3.6.1.4.1.4756.20.442.20.1.512ColumneddCISTAggregatedPointToPointRemoteBread-writecurrentEDD Series card STP CIST Port Configuration: CIST Aggregated Port Configuration - Point-to-point 0: Forced True 1: Forced False 2: Auto
1.3.6.1.4.1.4756.20.442.20.1.513ColumneddCISTPort1STPEnabledRemoteBread-writecurrentEDD Series card STP CIST Port Configuration: CIST Normal Port1 Configuration - STP Enabled
1.3.6.1.4.1.4756.20.442.20.1.514ColumneddCISTPort1PathCostRemoteBread-writecurrentEDD Series card STP CIST Port Configuration: CIST Normal Port1 Configuration - Path Cost Valid values are in the range 0 to 200000000. Setting 0 means Auto pat…
1.3.6.1.4.1.4756.20.442.20.1.515ColumneddCISTPort1PriorityRemoteBread-writecurrentEDD Series card STP CIST Port Configuration: CIST Normal Port1 Configuration - Priority
1.3.6.1.4.1.4756.20.442.20.1.516ColumneddCISTPort1AdminEdgeRemoteBread-writecurrentEDD Series card STP CIST Port Configuration: CIST Normal Port1 Configuration - STP Enabled 0: Non-edge 1: Edge
1.3.6.1.4.1.4756.20.442.20.1.517ColumneddCISTPort1AutoEdgeRemoteBread-writecurrentEDD Series card STP CIST Port Configuration: CIST Normal Port1 Configuration - Auto Edge 0: Non-edge 1: Edge
1.3.6.1.4.1.4756.20.442.20.1.518ColumneddCISTPort1RestrictedRoleRemoteBread-writecurrentEDD Series card STP CIST Port Configuration: CIST Normal Port1 Configuration - Restricted Role 0: Non-edge 1: Edge
1.3.6.1.4.1.4756.20.442.20.1.519ColumneddCISTPort1RestrictedTCNRemoteBread-writecurrentEDD Series card STP CIST Port Configuration: CIST Normal Port1 Configuration - Restricted TCN 0: Non-edge 1: Edge
1.3.6.1.4.1.4756.20.442.20.1.520ColumneddCISTPort1BPDUGuardRemoteBread-writecurrentEDD Series card STP CIST Port Configuration: CIST Normal Port1 Configuration - BPDU Guard 0: Non-edge 1: Edge
1.3.6.1.4.1.4756.20.442.20.1.521ColumneddCISTPort1PointToPointRemoteBread-writecurrentEDD Series card STP CIST Port Configuration: CIST Normal Port1 Configuration - Point-to-point 0: Forced True 1: Forced False 2: Auto
1.3.6.1.4.1.4756.20.442.20.1.522ColumneddCISTPort2STPEnabledRemoteBread-writecurrentEDD Series card STP CIST Port Configuration: CIST Normal Port2 Configuration - STP Enabled
1.3.6.1.4.1.4756.20.442.20.1.523ColumneddCISTPort2PathCostRemoteBread-writecurrentEDD Series card STP CIST Port Configuration: CIST Normal Port2 Configuration - Path Cost Valid values are in the range 0 to 200000000. Setting 0 means Auto pat…
1.3.6.1.4.1.4756.20.442.20.1.524ColumneddCISTPort2PriorityRemoteBread-writecurrentEDD Series card STP CIST Port Configuration: CIST Normal Port2 Configuration - Priority
1.3.6.1.4.1.4756.20.442.20.1.525ColumneddCISTPort2AdminEdgeRemoteBread-writecurrentEDD Series card STP CIST Port Configuration: CIST Normal Port2 Configuration - STP Enabled 0: Non-edge 1: Edge
1.3.6.1.4.1.4756.20.442.20.1.526ColumneddCISTPort2AutoEdgeRemoteBread-writecurrentEDD Series card STP CIST Port Configuration: CIST Normal Port2 Configuration - Auto Edge 0: Non-edge 1: Edge
1.3.6.1.4.1.4756.20.442.20.1.527ColumneddCISTPort2RestrictedRoleRemoteBread-writecurrentEDD Series card STP CIST Port Configuration: CIST Normal Port2 Configuration - Restricted Role 0: Non-edge 1: Edge
1.3.6.1.4.1.4756.20.442.20.1.528ColumneddCISTPort2RestrictedTCNRemoteBread-writecurrentEDD Series card STP CIST Port Configuration: CIST Normal Port2 Configuration - Restricted TCN 0: Non-edge 1: Edge
1.3.6.1.4.1.4756.20.442.20.1.529ColumneddCISTPort2BPDUGuardRemoteBread-writecurrentEDD Series card STP CIST Port Configuration: CIST Normal Port2 Configuration - BPDU Guard 0: Non-edge 1: Edge
1.3.6.1.4.1.4756.20.442.20.1.530ColumneddCISTPort2PointToPointRemoteBread-writecurrentEDD Series card STP CIST Port Configuration: CIST Normal Port2 Configuration - Point-to-point 0: Forced True 1: Forced False 2: Auto
1.3.6.1.4.1.4756.20.442.20.1.531ColumneddCISTPort3STPEnabledRemoteBread-writecurrentEDD Series card STP CIST Port Configuration: CIST Normal Port3 Configuration - STP Enabled
1.3.6.1.4.1.4756.20.442.20.1.532ColumneddCISTPort3PathCostRemoteBread-writecurrentEDD Series card STP CIST Port Configuration: CIST Normal Port3 Configuration - Path Cost Valid values are in the range 0 to 200000000. Setting 0 means Auto pat…
1.3.6.1.4.1.4756.20.442.20.1.533ColumneddCISTPort3PriorityRemoteBread-writecurrentEDD Series card STP CIST Port Configuration: CIST Normal Port3 Configuration - Priority
1.3.6.1.4.1.4756.20.442.20.1.534ColumneddCISTPort3AdminEdgeRemoteBread-writecurrentEDD Series card STP CIST Port Configuration: CIST Normal Port3 Configuration - STP Enabled 0: Non-edge 1: Edge
1.3.6.1.4.1.4756.20.442.20.1.535ColumneddCISTPort3AutoEdgeRemoteBread-writecurrentEDD Series card STP CIST Port Configuration: CIST Normal Port3 Configuration - Auto Edge 0: Non-edge 1: Edge
1.3.6.1.4.1.4756.20.442.20.1.536ColumneddCISTPort3RestrictedRoleRemoteBread-writecurrentEDD Series card STP CIST Port Configuration: CIST Normal Port3 Configuration - Restricted Role 0: Non-edge 1: Edge
1.3.6.1.4.1.4756.20.442.20.1.537ColumneddCISTPort3RestrictedTCNRemoteBread-writecurrentEDD Series card STP CIST Port Configuration: CIST Normal Port3 Configuration - Restricted TCN 0: Non-edge 1: Edge
1.3.6.1.4.1.4756.20.442.20.1.538ColumneddCISTPort3BPDUGuardRemoteBread-writecurrentEDD Series card STP CIST Port Configuration: CIST Normal Port3 Configuration - BPDU Guard 0: Non-edge 1: Edge
1.3.6.1.4.1.4756.20.442.20.1.539ColumneddCISTPort3PointToPointRemoteBread-writecurrentEDD Series card STP CIST Port Configuration: CIST Normal Port3 Configuration - Point-to-point 0: Forced True 1: Forced False 2: Auto
1.3.6.1.4.1.4756.20.442.20.1.540ColumneddCISTPort4STPEnabledRemoteBread-writecurrentEDD Series card STP CIST Port Configuration: CIST Normal Port4 Configuration - STP Enabled
1.3.6.1.4.1.4756.20.442.20.1.541ColumneddCISTPort4PathCostRemoteBread-writecurrentEDD Series card STP CIST Port Configuration: CIST Normal Port4 Configuration - Path Cost Valid values are in the range 0 to 200000000. Setting 0 means Auto pat…
1.3.6.1.4.1.4756.20.442.20.1.542ColumneddCISTPort4PriorityRemoteBread-writecurrentEDD Series card STP CIST Port Configuration: CIST Normal Port4 Configuration - Priority
1.3.6.1.4.1.4756.20.442.20.1.543ColumneddCISTPort4AdminEdgeRemoteBread-writecurrentEDD Series card STP CIST Port Configuration: CIST Normal Port4 Configuration - STP Enabled 0: Non-edge 1: Edge
1.3.6.1.4.1.4756.20.442.20.1.544ColumneddCISTPort4AutoEdgeRemoteBread-writecurrentEDD Series card STP CIST Port Configuration: CIST Normal Port4 Configuration - Auto Edge 0: Non-edge 1: Edge
1.3.6.1.4.1.4756.20.442.20.1.545ColumneddCISTPort4RestrictedRoleRemoteBread-writecurrentEDD Series card STP CIST Port Configuration: CIST Normal Port4 Configuration - Restricted Role 0: Non-edge 1: Edge
1.3.6.1.4.1.4756.20.442.20.1.546ColumneddCISTPort4RestrictedTCNRemoteBread-writecurrentEDD Series card STP CIST Port Configuration: CIST Normal Port4 Configuration - Restricted TCN 0: Non-edge 1: Edge
1.3.6.1.4.1.4756.20.442.20.1.547ColumneddCISTPort4BPDUGuardRemoteBread-writecurrentEDD Series card STP CIST Port Configuration: CIST Normal Port4 Configuration - BPDU Guard 0: Non-edge 1: Edge
1.3.6.1.4.1.4756.20.442.20.1.548ColumneddCISTPort4PointToPointRemoteBread-writecurrentEDD Series card STP CIST Port Configuration: CIST Normal Port4 Configuration - Point-to-point 0: Forced True 1: Forced False 2: Auto
1.3.6.1.4.1.4756.20.442.20.1.549ColumneddMSTI1AggregatedPathCostRemoteBread-writecurrentEDD Series card MSTI Port Configuration: MSTI1 Aggregated Ports Configuration - Path Cost Valid values are in the range 0 to 200000000. Setting 0 means Auto pa…
1.3.6.1.4.1.4756.20.442.20.1.550ColumneddMSTI1AggregatedPriorityRemoteBread-writecurrentEDD Series card MSTI Port Configuration: MSTI1 Aggregated Ports Configuration - Priority
1.3.6.1.4.1.4756.20.442.20.1.551ColumneddMSTI1Port1PathCostRemoteBread-writecurrentEDD Series card MSTI Port Configuration: MSTI1 Normal Port1 Configuration - Path Cost Valid values are in the range 0 to 200000000. Setting 0 means Auto path c…
1.3.6.1.4.1.4756.20.442.20.1.552ColumneddMSTI1Port1PriorityRemoteBread-writecurrentEDD Series card MSTI Port Configuration: MSTI1 Normal Port1 Configuration - Priority
1.3.6.1.4.1.4756.20.442.20.1.553ColumneddMSTI1Port2PathCostRemoteBread-writecurrentEDD Series card MSTI Port Configuration: MSTI1 Normal Port2 Configuration - Path Cost Valid values are in the range 0 to 200000000. Setting 0 means Auto path c…
1.3.6.1.4.1.4756.20.442.20.1.554ColumneddMSTI1Port2PriorityRemoteBread-writecurrentEDD Series card MSTI Port Configuration: MSTI1 Normal Port2 Configuration - Priority
1.3.6.1.4.1.4756.20.442.20.1.555ColumneddMSTI1Port3PathCostRemoteBread-writecurrentEDD Series card MSTI Port Configuration: MSTI1 Normal Port3 Configuration - Path Cost Valid values are in the range 0 to 200000000. Setting 0 means Auto path c…
1.3.6.1.4.1.4756.20.442.20.1.556ColumneddMSTI1Port3PriorityRemoteBread-writecurrentEDD Series card MSTI Port Configuration: MSTI1 Normal Port3 Configuration - Priority
1.3.6.1.4.1.4756.20.442.20.1.557ColumneddMSTI1Port4PathCostRemoteBread-writecurrentEDD Series card MSTI Port Configuration: MSTI1 Normal Port4 Configuration - Path Cost Valid values are in the range 0 to 200000000. Setting 0 means Auto path c…
1.3.6.1.4.1.4756.20.442.20.1.558ColumneddMSTI1Port4PriorityRemoteBread-writecurrentEDD Series card MSTI Port Configuration: MSTI1 Normal Port4 Configuration - Priority
1.3.6.1.4.1.4756.20.442.20.1.559ColumneddMSTI2AggregatedPathCostRemoteBread-writecurrentEDD Series card MSTI Port Configuration: MSTI2 Aggregated Ports Configuration - Path Cost Valid values are in the range 0 to 200000000. Setting 0 means Auto pa…
1.3.6.1.4.1.4756.20.442.20.1.560ColumneddMSTI2AggregatedPriorityRemoteBread-writecurrentEDD Series card MSTI Port Configuration: MSTI2 Aggregated Ports Configuration - Priority
1.3.6.1.4.1.4756.20.442.20.1.561ColumneddMSTI2Port1PathCostRemoteBread-writecurrentEDD Series card MSTI Port Configuration: MSTI2 Normal Port1 Configuration - Path Cost Valid values are in the range 0 to 200000000. Setting 0 means Auto path c…
1.3.6.1.4.1.4756.20.442.20.1.562ColumneddMSTI2Port1PriorityRemoteBread-writecurrentEDD Series card MSTI Port Configuration: MSTI2 Normal Port1 Configuration - Priority
1.3.6.1.4.1.4756.20.442.20.1.563ColumneddMSTI2Port2PathCostRemoteBread-writecurrentEDD Series card MSTI Port Configuration: MSTI2 Normal Port2 Configuration - Path Cost Valid values are in the range 0 to 200000000. Setting 0 means Auto path c…
1.3.6.1.4.1.4756.20.442.20.1.564ColumneddMSTI2Port2PriorityRemoteBread-writecurrentEDD Series card MSTI Port Configuration: MSTI2 Normal Port2 Configuration - Priority
1.3.6.1.4.1.4756.20.442.20.1.565ColumneddMSTI2Port3PathCostRemoteBread-writecurrentEDD Series card MSTI Port Configuration: MSTI2 Normal Port3 Configuration - Path Cost Valid values are in the range 0 to 200000000. Setting 0 means Auto path c…
1.3.6.1.4.1.4756.20.442.20.1.566ColumneddMSTI2Port3PriorityRemoteBread-writecurrentEDD Series card MSTI Port Configuration: MSTI2 Normal Port3 Configuration - Priority
1.3.6.1.4.1.4756.20.442.20.1.567ColumneddMSTI2Port4PathCostRemoteBread-writecurrentEDD Series card MSTI Port Configuration: MSTI2 Normal Port4 Configuration - Path Cost Valid values are in the range 0 to 200000000. Setting 0 means Auto path c…
1.3.6.1.4.1.4756.20.442.20.1.568ColumneddMSTI2Port4PriorityRemoteBread-writecurrentEDD Series card MSTI Port Configuration: MSTI2 Normal Port4 Configuration - Priority
1.3.6.1.4.1.4756.20.442.20.1.569ColumneddMSTI3AggregatedPathCostRemoteBread-writecurrentEDD Series card MSTI Port Configuration: MSTI3 Aggregated Ports Configuration - Path Cost Valid values are in the range 0 to 200000000. Setting 0 means Auto pa…
1.3.6.1.4.1.4756.20.442.20.1.570ColumneddMSTI3AggregatedPriorityRemoteBread-writecurrentEDD Series card MSTI Port Configuration: MSTI3 Aggregated Ports Configuration - Priority
1.3.6.1.4.1.4756.20.442.20.1.571ColumneddMSTI3Port1PathCostRemoteBread-writecurrentEDD Series card MSTI Port Configuration: MSTI3 Normal Port1 Configuration - Path Cost Valid values are in the range 0 to 200000000. Setting 0 means Auto path c…
1.3.6.1.4.1.4756.20.442.20.1.572ColumneddMSTI3Port1PriorityRemoteBread-writecurrentEDD Series card MSTI Port Configuration: MSTI3 Normal Port1 Configuration - Priority
1.3.6.1.4.1.4756.20.442.20.1.573ColumneddMSTI3Port2PathCostRemoteBread-writecurrentEDD Series card MSTI Port Configuration: MSTI3 Normal Port2 Configuration - Path Cost Valid values are in the range 0 to 200000000. Setting 0 means Auto path c…
1.3.6.1.4.1.4756.20.442.20.1.574ColumneddMSTI3Port2PriorityRemoteBread-writecurrentEDD Series card MSTI Port Configuration: MSTI3 Normal Port2 Configuration - Priority
1.3.6.1.4.1.4756.20.442.20.1.575ColumneddMSTI3Port3PathCostRemoteBread-writecurrentEDD Series card MSTI Port Configuration: MSTI1 Normal Port3 Configuration - Path Cost Valid values are in the range 0 to 200000000. Setting 0 means Auto path c…
1.3.6.1.4.1.4756.20.442.20.1.576ColumneddMSTI3Port3PriorityRemoteBread-writecurrentEDD Series card MSTI Port Configuration: MSTI3 Normal Port3 Configuration - Priority
1.3.6.1.4.1.4756.20.442.20.1.577ColumneddMSTI3Port4PathCostRemoteBread-writecurrentEDD Series card MSTI Port Configuration: MSTI3 Normal Port4 Configuration - Path Cost Valid values are in the range 0 to 200000000. Setting 0 means Auto path c…
1.3.6.1.4.1.4756.20.442.20.1.578ColumneddMSTI3Port4PriorityRemoteBread-writecurrentEDD Series card MSTI Port Configuration: MSTI3 Normal Port4 Configuration - Priority
1.3.6.1.4.1.4756.20.442.20.1.579ColumneddMSTI4AggregatedPathCostRemoteBread-writecurrentEDD Series card MSTI Port Configuration: MSTI4 Aggregated Ports Configuration - Path Cost Valid values are in the range 0 to 200000000. Setting 0 means Auto pa…
1.3.6.1.4.1.4756.20.442.20.1.580ColumneddMSTI4AggregatedPriorityRemoteBread-writecurrentEDD Series card MSTI Port Configuration: MSTI4 Aggregated Ports Configuration - Priority
1.3.6.1.4.1.4756.20.442.20.1.581ColumneddMSTI4Port1PathCostRemoteBread-writecurrentEDD Series card MSTI Port Configuration: MSTI4 Normal Port1 Configuration - Path Cost Valid values are in the range 0 to 200000000. Setting 0 means Auto path c…
1.3.6.1.4.1.4756.20.442.20.1.582ColumneddMSTI4Port1PriorityRemoteBread-writecurrentEDD Series card MSTI Port Configuration: MSTI4 Normal Port1 Configuration - Priority
1.3.6.1.4.1.4756.20.442.20.1.583ColumneddMSTI4Port2PathCostRemoteBread-writecurrentEDD Series card MSTI Port Configuration: MSTI4 Normal Port2 Configuration - Path Cost Valid values are in the range 0 to 200000000. Setting 0 means Auto path c…
1.3.6.1.4.1.4756.20.442.20.1.584ColumneddMSTI4Port2PriorityRemoteBread-writecurrentEDD Series card MSTI Port Configuration: MSTI4 Normal Port2 Configuration - Priority
1.3.6.1.4.1.4756.20.442.20.1.585ColumneddMSTI4Port3PathCostRemoteBread-writecurrentEDD Series card MSTI Port Configuration: MSTI1 Normal Port3 Configuration - Path Cost Valid values are in the range 0 to 200000000. Setting 0 means Auto path c…
1.3.6.1.4.1.4756.20.442.20.1.586ColumneddMSTI4Port3PriorityRemoteBread-writecurrentEDD Series card MSTI Port Configuration: MSTI4 Normal Port3 Configuration - Priority
1.3.6.1.4.1.4756.20.442.20.1.587ColumneddMSTI4Port4PathCostRemoteBread-writecurrentEDD Series card MSTI Port Configuration: MSTI4 Normal Port4 Configuration - Path Cost Valid values are in the range 0 to 200000000. Setting 0 means Auto path c…
1.3.6.1.4.1.4756.20.442.20.1.588ColumneddMSTI4Port4PriorityRemoteBread-writecurrentEDD Series card MSTI Port Configuration: MSTI4 Normal Port4 Configuration - Priority
1.3.6.1.4.1.4756.20.442.20.1.589ColumneddMSTI5AggregatedPathCostRemoteBread-writecurrentEDD Series card MSTI Port Configuration: MSTI5 Aggregated Ports Configuration - Path Cost Valid values are in the range 0 to 200000000. Setting 0 means Auto pa…
1.3.6.1.4.1.4756.20.442.20.1.590ColumneddMSTI5AggregatedPriorityRemoteBread-writecurrentEDD Series card MSTI Port Configuration: MSTI5 Aggregated Ports Configuration - Priority
1.3.6.1.4.1.4756.20.442.20.1.591ColumneddMSTI5Port1PathCostRemoteBread-writecurrentEDD Series card MSTI Port Configuration: MSTI5 Normal Port1 Configuration - Path Cost Valid values are in the range 0 to 200000000. Setting 0 means Auto path c…
1.3.6.1.4.1.4756.20.442.20.1.592ColumneddMSTI5Port1PriorityRemoteBread-writecurrentEDD Series card MSTI Port Configuration: MSTI5 Normal Port1 Configuration - Priority
1.3.6.1.4.1.4756.20.442.20.1.593ColumneddMSTI5Port2PathCostRemoteBread-writecurrentEDD Series card MSTI Port Configuration: MSTI5 Normal Port2 Configuration - Path Cost Valid values are in the range 0 to 200000000. Setting 0 means Auto path c…
1.3.6.1.4.1.4756.20.442.20.1.594ColumneddMSTI5Port2PriorityRemoteBread-writecurrentEDD Series card MSTI Port Configuration: MSTI5 Normal Port2 Configuration - Priority
1.3.6.1.4.1.4756.20.442.20.1.595ColumneddMSTI5Port3PathCostRemoteBread-writecurrentEDD Series card MSTI Port Configuration: MSTI5 Normal Port3 Configuration - Path Cost Valid values are in the range 0 to 200000000. Setting 0 means Auto path c…
1.3.6.1.4.1.4756.20.442.20.1.596ColumneddMSTI5Port3PriorityRemoteBread-writecurrentEDD Series card MSTI Port Configuration: MSTI5 Normal Port3 Configuration - Priority
1.3.6.1.4.1.4756.20.442.20.1.597ColumneddMSTI5Port4PathCostRemoteBread-writecurrentEDD Series card MSTI Port Configuration: MSTI5 Normal Port4 Configuration - Path Cost Valid values are in the range 0 to 200000000. Setting 0 means Auto path c…
1.3.6.1.4.1.4756.20.442.20.1.598ColumneddMSTI5Port4PriorityRemoteBread-writecurrentEDD Series card MSTI Port Configuration: MSTI5 Normal Port4 Configuration - Priority
1.3.6.1.4.1.4756.20.442.20.1.599ColumneddMSTI6AggregatedPathCostRemoteBread-writecurrentEDD Series card MSTI Port Configuration: MSTI6 Aggregated Ports Configuration - Path Cost Valid values are in the range 0 to 200000000. Setting 0 means Auto pa…
1.3.6.1.4.1.4756.20.442.20.1.600ColumneddMSTI6AggregatedPriorityRemoteBread-writecurrentEDD Series card MSTI Port Configuration: MSTI6 Aggregated Ports Configuration - Priority
1.3.6.1.4.1.4756.20.442.20.1.601ColumneddMSTI6Port1PathCostRemoteBread-writecurrentEDD Series card MSTI Port Configuration: MSTI6 Normal Port1 Configuration - Path Cost Valid values are in the range 0 to 200000000. Setting 0 means Auto path c…
1.3.6.1.4.1.4756.20.442.20.1.602ColumneddMSTI6Port1PriorityRemoteBread-writecurrentEDD Series card MSTI Port Configuration: MSTI6 Normal Port1 Configuration - Priority
1.3.6.1.4.1.4756.20.442.20.1.603ColumneddMSTI6Port2PathCostRemoteBread-writecurrentEDD Series card MSTI Port Configuration: MSTI6 Normal Port2 Configuration - Path Cost Valid values are in the range 0 to 200000000. Setting 0 means Auto path c…
1.3.6.1.4.1.4756.20.442.20.1.604ColumneddMSTI6Port2PriorityRemoteBread-writecurrentEDD Series card MSTI Port Configuration: MSTI6 Normal Port2 Configuration - Priority
1.3.6.1.4.1.4756.20.442.20.1.605ColumneddMSTI6Port3PathCostRemoteBread-writecurrentEDD Series card MSTI Port Configuration: MSTI6 Normal Port3 Configuration - Path Cost Valid values are in the range 0 to 200000000. Setting 0 means Auto path c…
1.3.6.1.4.1.4756.20.442.20.1.606ColumneddMSTI6Port3PriorityRemoteBread-writecurrentEDD Series card MSTI Port Configuration: MSTI6 Normal Port3 Configuration - Priority
1.3.6.1.4.1.4756.20.442.20.1.607ColumneddMSTI6Port4PathCostRemoteBread-writecurrentEDD Series card MSTI Port Configuration: MSTI6 Normal Port4 Configuration - Path Cost Valid values are in the range 0 to 200000000. Setting 0 means Auto path c…
1.3.6.1.4.1.4756.20.442.20.1.608ColumneddMSTI6Port4PriorityRemoteBread-writecurrentEDD Series card MSTI Port Configuration: MSTI6 Normal Port4 Configuration - Priority
1.3.6.1.4.1.4756.20.442.20.1.609ColumneddMSTI7AggregatedPathCostRemoteBread-writecurrentEDD Series card MSTI Port Configuration: MSTI7 Aggregated Ports Configuration - Path Cost Valid values are in the range 0 to 200000000. Setting 0 means Auto pa…
1.3.6.1.4.1.4756.20.442.20.1.610ColumneddMSTI7AggregatedPriorityRemoteBread-writecurrentEDD Series card MSTI Port Configuration: MSTI7 Aggregated Ports Configuration - Priority
1.3.6.1.4.1.4756.20.442.20.1.611ColumneddMSTI7Port1PathCostRemoteBread-writecurrentEDD Series card MSTI Port Configuration: MSTI1 Normal Port1 Configuration - Path Cost Valid values are in the range 0 to 200000000. Setting 0 means Auto path c…
1.3.6.1.4.1.4756.20.442.20.1.612ColumneddMSTI7Port1PriorityRemoteBread-writecurrentEDD Series card MSTI Port Configuration: MSTI1 Normal Port7 Configuration - Priority
1.3.6.1.4.1.4756.20.442.20.1.613ColumneddMSTI7Port2PathCostRemoteBread-writecurrentEDD Series card MSTI Port Configuration: MSTI7 Normal Port2 Configuration - Path Cost Valid values are in the range 0 to 200000000. Setting 0 means Auto path c…
1.3.6.1.4.1.4756.20.442.20.1.614ColumneddMSTI7Port2PriorityRemoteBread-writecurrentEDD Series card MSTI Port Configuration: MSTI7 Normal Port2 Configuration - Priority
1.3.6.1.4.1.4756.20.442.20.1.615ColumneddMSTI7Port3PathCostRemoteBread-writecurrentEDD Series card MSTI Port Configuration: MSTI7 Normal Port3 Configuration - Path Cost Valid values are in the range 0 to 200000000. Setting 0 means Auto path c…
1.3.6.1.4.1.4756.20.442.20.1.616ColumneddMSTI7Port3PriorityRemoteBread-writecurrentEDD Series card MSTI Port Configuration: MSTI7 Normal Port3 Configuration - Priority
1.3.6.1.4.1.4756.20.442.20.1.617ColumneddMSTI7Port4PathCostRemoteBread-writecurrentEDD Series card MSTI Port Configuration: MSTI7 Normal Port4 Configuration - Path Cost Valid values are in the range 0 to 200000000. Setting 0 means Auto path c…
1.3.6.1.4.1.4756.20.442.20.1.618ColumneddMSTI7Port4PriorityRemoteBread-writecurrentEDD Series card MSTI Port Configuration: MSTI7 Normal Port4 Configuration - Priority
1.3.6.1.4.1.4756.20.442.20.1.619ColumneddCISTBridgeIDRemoteBread-onlycurrentEDD Series card STP Bridges status: CIST - Bridge ID
1.3.6.1.4.1.4756.20.442.20.1.620ColumneddCISTRootIDRemoteBread-onlycurrentEDD Series card STP Bridges status: CIST - Root ID
1.3.6.1.4.1.4756.20.442.20.1.621ColumneddCISTRootPortRemoteBread-onlycurrentEDD Series card STP Bridges status: CIST - Root Port
1.3.6.1.4.1.4756.20.442.20.1.622ColumneddCISTRootCostRemoteBread-onlycurrentEDD Series card STP Bridges status: CIST - Root Cost
1.3.6.1.4.1.4756.20.442.20.1.623ColumneddCISTTopologyFlagRemoteBread-onlycurrentEDD Series card STP Bridges status: CIST - Topology Flag
1.3.6.1.4.1.4756.20.442.20.1.624ColumneddCISTTopologyChangeLastRemoteBread-onlycurrentEDD Series card STP Bridges status: CIST - Topology Change Last
1.3.6.1.4.1.4756.20.442.20.1.625ColumneddMSTI1BridgeIDRemoteBread-onlycurrentEDD Series card STP Bridges status: MSTI1 - Bridge ID
1.3.6.1.4.1.4756.20.442.20.1.626ColumneddMSTI1RootIDRemoteBread-onlycurrentEDD Series card STP Bridges status: MSTI1 - Root ID
1.3.6.1.4.1.4756.20.442.20.1.627ColumneddMSTI1RootPortRemoteBread-onlycurrentEDD Series card STP Bridges status: MSTI1 - Root ID
1.3.6.1.4.1.4756.20.442.20.1.628ColumneddMSTI1RootCostRemoteBread-onlycurrentEDD Series card STP Bridges status: MSTI1 - Root Cost
1.3.6.1.4.1.4756.20.442.20.1.629ColumneddMSTI1TopologyFlagRemoteBread-onlycurrentEDD Series card STP Bridges status: MSTI1 - Topology Flag
1.3.6.1.4.1.4756.20.442.20.1.630ColumneddMSTI1TopologyChangeLastRemoteBread-onlycurrentEDD Series card STP Bridges status: MSTI1 - Topology Change Last
1.3.6.1.4.1.4756.20.442.20.1.631ColumneddMSTI2BridgeIDRemoteBread-onlycurrentEDD Series card STP Bridges status: MSTI2 - Bridge ID
1.3.6.1.4.1.4756.20.442.20.1.632ColumneddMSTI2RootIDRemoteBread-onlycurrentEDD Series card STP Bridges status: MSTI2 - Root ID
1.3.6.1.4.1.4756.20.442.20.1.633ColumneddMSTI2RootPortRemoteBread-onlycurrentEDD Series card STP Bridges status: MSTI2 - Root ID
1.3.6.1.4.1.4756.20.442.20.1.634ColumneddMSTI2RootCostRemoteBread-onlycurrentEDD Series card STP Bridges status: MSTI2 - Root Cost
1.3.6.1.4.1.4756.20.442.20.1.635ColumneddMSTI2TopologyFlagRemoteBread-onlycurrentEDD Series card STP Bridges status: MSTI2 - Topology Flag
1.3.6.1.4.1.4756.20.442.20.1.636ColumneddMSTI2TopologyChangeLastRemoteBread-onlycurrentEDD Series card STP Bridges status: MSTI2 - Topology Change Last
1.3.6.1.4.1.4756.20.442.20.1.637ColumneddMSTI3BridgeIDRemoteBread-onlycurrentEDD Series card STP Bridges status: MSTI3 - Bridge ID
1.3.6.1.4.1.4756.20.442.20.1.638ColumneddMSTI3RootIDRemoteBread-onlycurrentEDD Series card STP Bridges status: MSTI3 - Root ID
1.3.6.1.4.1.4756.20.442.20.1.639ColumneddMSTI3RootPortRemoteBread-onlycurrentEDD Series card STP Bridges status: MSTI3 - Root ID
1.3.6.1.4.1.4756.20.442.20.1.640ColumneddMSTI3RootCostRemoteBread-onlycurrentEDD Series card STP Bridges status: MSTI3 - Root Cost
1.3.6.1.4.1.4756.20.442.20.1.641ColumneddMSTI3TopologyFlagRemoteBread-onlycurrentEDD Series card STP Bridges status: MSTI3 - Topology Flag
1.3.6.1.4.1.4756.20.442.20.1.642ColumneddMSTI3TopologyChangeLastRemoteBread-onlycurrentEDD Series card STP Bridges status: MSTI3 - Topology Change Last
1.3.6.1.4.1.4756.20.442.20.1.643ColumneddMSTI4BridgeIDRemoteBread-onlycurrentEDD Series card STP Bridges status: MSTI4 - Bridge ID
1.3.6.1.4.1.4756.20.442.20.1.644ColumneddMSTI4RootIDRemoteBread-onlycurrentEDD Series card STP Bridges status: MSTI4 - Root ID
1.3.6.1.4.1.4756.20.442.20.1.645ColumneddMSTI4RootPortRemoteBread-onlycurrentEDD Series card STP Bridges status: MSTI4 - Root ID
1.3.6.1.4.1.4756.20.442.20.1.646ColumneddMSTI4RootCostRemoteBread-onlycurrentEDD Series card STP Bridges status: MSTI4 - Root Cost
1.3.6.1.4.1.4756.20.442.20.1.647ColumneddMSTI4TopologyFlagRemoteBread-onlycurrentEDD Series card STP Bridges status: MSTI4 - Topology Flag
1.3.6.1.4.1.4756.20.442.20.1.648ColumneddMSTI4TopologyChangeLastRemoteBread-onlycurrentEDD Series card STP Bridges status: MSTI4 - Topology Change Last
1.3.6.1.4.1.4756.20.442.20.1.649ColumneddMSTI5BridgeIDRemoteBread-onlycurrentEDD Series card STP Bridges status: MSTI5 - Bridge ID
1.3.6.1.4.1.4756.20.442.20.1.650ColumneddMSTI5RootIDRemoteBread-onlycurrentEDD Series card STP Bridges status: MSTI5 - Root ID
1.3.6.1.4.1.4756.20.442.20.1.651ColumneddMSTI5RootPortRemoteBread-onlycurrentEDD Series card STP Bridges status: MSTI5 - Root ID
1.3.6.1.4.1.4756.20.442.20.1.652ColumneddMSTI5RootCostRemoteBread-onlycurrentEDD Series card STP Bridges status: MSTI5 - Root Cost
1.3.6.1.4.1.4756.20.442.20.1.653ColumneddMSTI5TopologyFlagRemoteBread-onlycurrentEDD Series card STP Bridges status: MSTI5 - Topology Flag
1.3.6.1.4.1.4756.20.442.20.1.654ColumneddMSTI5TopologyChangeLastRemoteBread-onlycurrentEDD Series card STP Bridges status: MSTI5 - Topology Change Last
1.3.6.1.4.1.4756.20.442.20.1.655ColumneddMSTI6BridgeIDRemoteBread-onlycurrentEDD Series card STP Bridges status: MSTI6 - Bridge ID
1.3.6.1.4.1.4756.20.442.20.1.656ColumneddMSTI6RootIDRemoteBread-onlycurrentEDD Series card STP Bridges status: MSTI6 - Root ID
1.3.6.1.4.1.4756.20.442.20.1.657ColumneddMSTI6RootPortRemoteBread-onlycurrentEDD Series card STP Bridges status: MSTI6 - Root ID
1.3.6.1.4.1.4756.20.442.20.1.658ColumneddMSTI6RootCostRemoteBread-onlycurrentEDD Series card STP Bridges status: MSTI6 - Root Cost
1.3.6.1.4.1.4756.20.442.20.1.659ColumneddMSTI6TopologyFlagRemoteBread-onlycurrentEDD Series card STP Bridges status: MSTI6 - Topology Flag
1.3.6.1.4.1.4756.20.442.20.1.660ColumneddMSTI6TopologyChangeLastRemoteBread-onlycurrentEDD Series card STP Bridges status: MSTI6 - Topology Change Last
1.3.6.1.4.1.4756.20.442.20.1.661ColumneddMSTI7BridgeIDRemoteBread-onlycurrentEDD Series card STP Bridges status: MSTI7 - Bridge ID
1.3.6.1.4.1.4756.20.442.20.1.662ColumneddMSTI7RootIDRemoteBread-onlycurrentEDD Series card STP Bridges status: MSTI7 - Root ID
1.3.6.1.4.1.4756.20.442.20.1.663ColumneddMSTI7RootPortRemoteBread-onlycurrentEDD Series card STP Bridges status: MSTI7 - Root ID
1.3.6.1.4.1.4756.20.442.20.1.664ColumneddMSTI7RootCostRemoteBread-onlycurrentEDD Series card STP Bridges status: MSTI7 - Root Cost
1.3.6.1.4.1.4756.20.442.20.1.665ColumneddMSTI7TopologyFlagRemoteBread-onlycurrentEDD Series card STP Bridges status: MSTI7 - Topology Flag
1.3.6.1.4.1.4756.20.442.20.1.666ColumneddMSTI7TopologyChangeLastRemoteBread-onlycurrentEDD Series card STP Bridges status: MSTI7 - Topology Change Last
1.3.6.1.4.1.4756.20.442.20.1.667ColumneddSTPPortStatusInst1PortRemoteBread-onlycurrentEDD Series card STP Port status: Instance1 - Port
1.3.6.1.4.1.4756.20.442.20.1.668ColumneddSTPPortStatusInst1CISTRoleRemoteBread-onlycurrentEDD Series card STP Port status: Instance1 - CIST Role
1.3.6.1.4.1.4756.20.442.20.1.669ColumneddSTPPortStatusInst1CISTStateRemoteBread-onlycurrentEDD Series card STP Port status: Instance1 - CIST State
1.3.6.1.4.1.4756.20.442.20.1.670ColumneddSTPPortStatusInst1UptimeRemoteBread-onlycurrentEDD Series card STP Port status: Instance1 -Uptime
1.3.6.1.4.1.4756.20.442.20.1.671ColumneddSTPPortStatusInst2PortRemoteBread-onlycurrentEDD Series card STP Port status: Instance2 - Port
1.3.6.1.4.1.4756.20.442.20.1.672ColumneddSTPPortStatusInst2CISTRoleRemoteBread-onlycurrentEDD Series card STP Port status: Instance2 - CIST Role
1.3.6.1.4.1.4756.20.442.20.1.673ColumneddSTPPortStatusInst2CISTStateRemoteBread-onlycurrentEDD Series card STP Port status: Instance2 - CIST State
1.3.6.1.4.1.4756.20.442.20.1.674ColumneddSTPPortStatusInst2UptimeRemoteBread-onlycurrentEDD Series card STP Port status: Instance2 -Uptime
1.3.6.1.4.1.4756.20.442.20.1.675ColumneddSTPPortStatusInst3PortRemoteBread-onlycurrentEDD Series card STP Port status: Instance3 - Port
1.3.6.1.4.1.4756.20.442.20.1.676ColumneddSTPPortStatusInst3CISTRoleRemoteBread-onlycurrentEDD Series card STP Port status: Instance3 - CIST Role
1.3.6.1.4.1.4756.20.442.20.1.677ColumneddSTPPortStatusInst3CISTStateRemoteBread-onlycurrentEDD Series card STP Port status: Instance3 - CIST State
1.3.6.1.4.1.4756.20.442.20.1.678ColumneddSTPPortStatusInst3UptimeRemoteBread-onlycurrentEDD Series card STP Port status: Instance3 -Uptime
1.3.6.1.4.1.4756.20.442.20.1.679ColumneddSTPPortStatusInst4PortRemoteBread-onlycurrentEDD Series card STP Port status: Instance4 - Port
1.3.6.1.4.1.4756.20.442.20.1.680ColumneddSTPPortStatusInst4CISTRoleRemoteBread-onlycurrentEDD Series card STP Port status: Instance4 - CIST Role
1.3.6.1.4.1.4756.20.442.20.1.681ColumneddSTPPortStatusInst4CISTStateRemoteBread-onlycurrentEDD Series card STP Port status: Instance4 - CIST State
1.3.6.1.4.1.4756.20.442.20.1.682ColumneddSTPPortStatusInst4UptimeRemoteBread-onlycurrentEDD Series card STP Port status: Instance4 -Uptime
1.3.6.1.4.1.4756.20.442.20.1.683ColumneddSTPStatisticsPort1TxMSTPRemoteBread-onlycurrentEDD Series card STP Port Statistics: Port1 -Transmitted MSTP
1.3.6.1.4.1.4756.20.442.20.1.684ColumneddSTPStatisticsPort1TxRSTPRemoteBread-onlycurrentEDD Series card STP Port Statistics: Port1 -Transmitted RSTP
1.3.6.1.4.1.4756.20.442.20.1.685ColumneddSTPStatisticsPort1TxSTPRemoteBread-onlycurrentEDD Series card STP Port Statistics: Port1 -Transmitted RSTP
1.3.6.1.4.1.4756.20.442.20.1.686ColumneddSTPStatisticsPort1TxTCNRemoteBread-onlycurrentEDD Series card STP Port Statistics: Port1 -Transmitted RSTP
1.3.6.1.4.1.4756.20.442.20.1.687ColumneddSTPStatisticsPort1RxMSTPRemoteBread-onlycurrentEDD Series card STP Port Statistics: Port1 -Received MSTP
1.3.6.1.4.1.4756.20.442.20.1.688ColumneddSTPStatisticsPort1RxRSTPRemoteBread-onlycurrentEDD Series card STP Port Statistics: Port1 -Received RSTP
1.3.6.1.4.1.4756.20.442.20.1.689ColumneddSTPStatisticsPort1RxSTPRemoteBread-onlycurrentEDD Series card STP Port Statistics: Port1 -Received RSTP
1.3.6.1.4.1.4756.20.442.20.1.690ColumneddSTPStatisticsPort1RxTCNRemoteBread-onlycurrentEDD Series card STP Port Statistics: Port1 -Received RSTP
1.3.6.1.4.1.4756.20.442.20.1.691ColumneddSTPStatisticsPort1DiscardUnknowRemoteBread-onlycurrentEDD Series card STP Port Statistics: Port1 -Discarded Unknown
1.3.6.1.4.1.4756.20.442.20.1.692ColumneddSTPStatisticsPort1DiscardIllegalRemoteBread-onlycurrentEDD Series card STP Port Statistics: Port1 -Discarded Illegal
1.3.6.1.4.1.4756.20.442.20.1.693ColumneddSTPStatisticsPort2TxMSTPRemoteBread-onlycurrentEDD Series card STP Port Statistics: Port2 -Transmitted MSTP
1.3.6.1.4.1.4756.20.442.20.1.694ColumneddSTPStatisticsPort2TxRSTPRemoteBread-onlycurrentEDD Series card STP Port Statistics: Port2 -Transmitted RSTP
1.3.6.1.4.1.4756.20.442.20.1.695ColumneddSTPStatisticsPort2TxSTPRemoteBread-onlycurrentEDD Series card STP Port Statistics: Port2 -Transmitted RSTP
1.3.6.1.4.1.4756.20.442.20.1.696ColumneddSTPStatisticsPort2TxTCNRemoteBread-onlycurrentEDD Series card STP Port Statistics: Port2 -Transmitted RSTP
1.3.6.1.4.1.4756.20.442.20.1.697ColumneddSTPStatisticsPort2RxMSTPRemoteBread-onlycurrentEDD Series card STP Port Statistics: Port2 -Received MSTP
1.3.6.1.4.1.4756.20.442.20.1.698ColumneddSTPStatisticsPort2RxRSTPRemoteBread-onlycurrentEDD Series card STP Port Statistics: Port1 -Received RSTP
1.3.6.1.4.1.4756.20.442.20.1.699ColumneddSTPStatisticsPort2RxSTPRemoteBread-onlycurrentEDD Series card STP Port Statistics: Port2 -Received RSTP
1.3.6.1.4.1.4756.20.442.20.1.700ColumneddSTPStatisticsPort2RxTCNRemoteBread-onlycurrentEDD Series card STP Port Statistics: Port2 -Received RSTP
1.3.6.1.4.1.4756.20.442.20.1.701ColumneddSTPStatisticsPort2DiscardUnknowRemoteBread-onlycurrentEDD Series card STP Port Statistics: Port2 -Discarded Unknown
1.3.6.1.4.1.4756.20.442.20.1.702ColumneddSTPStatisticsPort2DiscardIllegalRemoteBread-onlycurrentEDD Series card STP Port Statistics: Port2 -Discarded Illegal
1.3.6.1.4.1.4756.20.442.20.1.703ColumneddSTPStatisticsPort3TxMSTPRemoteBread-onlycurrentEDD Series card STP Port Statistics: Port3 -Transmitted MSTP
1.3.6.1.4.1.4756.20.442.20.1.704ColumneddSTPStatisticsPort3TxRSTPRemoteBread-onlycurrentEDD Series card STP Port Statistics: Port3 -Transmitted RSTP
1.3.6.1.4.1.4756.20.442.20.1.705ColumneddSTPStatisticsPort3TxSTPRemoteBread-onlycurrentEDD Series card STP Port Statistics: Port3 -Transmitted RSTP
1.3.6.1.4.1.4756.20.442.20.1.706ColumneddSTPStatisticsPort3TxTCNRemoteBread-onlycurrentEDD Series card STP Port Statistics: Port3 -Transmitted RSTP
1.3.6.1.4.1.4756.20.442.20.1.707ColumneddSTPStatisticsPort3RxMSTPRemoteBread-onlycurrentEDD Series card STP Port Statistics: Port3 -Received MSTP
1.3.6.1.4.1.4756.20.442.20.1.708ColumneddSTPStatisticsPort3RxRSTPRemoteBread-onlycurrentEDD Series card STP Port Statistics: Port3 -Received RSTP
1.3.6.1.4.1.4756.20.442.20.1.709ColumneddSTPStatisticsPort3RxSTPRemoteBread-onlycurrentEDD Series card STP Port Statistics: Port3 -Received RSTP
1.3.6.1.4.1.4756.20.442.20.1.710ColumneddSTPStatisticsPort3RxTCNRemoteBread-onlycurrentEDD Series card STP Port Statistics: Port3 -Received RSTP
1.3.6.1.4.1.4756.20.442.20.1.711ColumneddSTPStatisticsPort3DiscardUnknowRemoteBread-onlycurrentEDD Series card STP Port Statistics: Port3 -Discarded Unknown
1.3.6.1.4.1.4756.20.442.20.1.712ColumneddSTPStatisticsPort3DiscardIllegalRemoteBread-onlycurrentEDD Series card STP Port Statistics: Port3 -Discarded Illegal
1.3.6.1.4.1.4756.20.442.20.1.713ColumneddSTPStatisticsPort4TxMSTPRemoteBread-onlycurrentEDD Series card STP Port Statistics: Port4 -Transmitted MSTP
1.3.6.1.4.1.4756.20.442.20.1.714ColumneddSTPStatisticsPort4TxRSTPRemoteBread-onlycurrentEDD Series card STP Port Statistics: Port4 -Transmitted RSTP
1.3.6.1.4.1.4756.20.442.20.1.715ColumneddSTPStatisticsPort4TxSTPRemoteBread-onlycurrentEDD Series card STP Port Statistics: Port4 -Transmitted RSTP
1.3.6.1.4.1.4756.20.442.20.1.716ColumneddSTPStatisticsPort4TxTCNRemoteBread-onlycurrentEDD Series card STP Port Statistics: Port4 -Transmitted RSTP
1.3.6.1.4.1.4756.20.442.20.1.717ColumneddSTPStatisticsPort4RxMSTPRemoteBread-onlycurrentEDD Series card STP Port Statistics: Port4 -Received MSTP
1.3.6.1.4.1.4756.20.442.20.1.718ColumneddSTPStatisticsPort4RxRSTPRemoteBread-onlycurrentEDD Series card STP Port Statistics: Port4 -Received RSTP
1.3.6.1.4.1.4756.20.442.20.1.719ColumneddSTPStatisticsPort4RxSTPRemoteBread-onlycurrentEDD Series card STP Port Statistics: Port4 -Received RSTP
1.3.6.1.4.1.4756.20.442.20.1.720ColumneddSTPStatisticsPort4RxTCNRemoteBread-onlycurrentEDD Series card STP Port Statistics: Port4 -Received RSTP
1.3.6.1.4.1.4756.20.442.20.1.721ColumneddSTPStatisticsPort4DiscardUnknowRemoteBread-onlycurrentEDD Series card STP Port Statistics: Port4 -Discarded Unknown
1.3.6.1.4.1.4756.20.442.20.1.722ColumneddSTPStatisticsPort4DiscardIllegalRemoteBread-onlycurrentEDD Series card STP Port Statistics: Port4 -Discarded Illegal
1.3.6.1.4.1.4756.20.442.20.1.723ColumneddSTPStatisticsPortClearCounterRemoteBread-writecurrentEDD Series card STP Port Statistics: Clear Counters 0: OFff 1: Action
1.3.6.1.4.1.4756.20.442.20.1.724ColumneddAllowedAccessVLANsRemoteBread-writecurrentEDD Series card Global VLAN Configuration: Allowed Access VLANs By default, only VLAN 1 is enabled. More VLANs may be created by using a list syntax where the …
1.3.6.1.4.1.4756.20.442.20.1.725ColumneddVlanEthertypeRemoteBread-writecurrentEDD Series card Global VLAN Configuration: Ethertype for Custom S-ports The format of 'Ethernet Type' is restricted to 0x600-0xFFFF
1.3.6.1.4.1.4756.20.442.20.1.726ColumneddPort1VlanModeRemoteBread-writecurrentEDD Series card Port VLAN Configuration : Port1 - Mode 0: Access 1: Trunk 2: Hybrid
1.3.6.1.4.1.4756.20.442.20.1.727ColumneddPort1VlanIDRemoteBread-writecurrentEDD Series card Port VLAN Configuration : Port1 - VLAN ID
1.3.6.1.4.1.4756.20.442.20.1.728ColumneddPort1VlanTypeRemoteBread-writecurrentEDD Series card Port VLAN Configuration : Port1 - VLAN Type 0: Unaware 1: C-port 2: S-port 3: S-custom-port
1.3.6.1.4.1.4756.20.442.20.1.729ColumneddPort1VlanIngressFilteringRemoteBread-writecurrentEDD Series card Port VLAN Configuration : Port1 - Ingress Filtering 0: Off 1: On
1.3.6.1.4.1.4756.20.442.20.1.730ColumneddPort1VlanIngressAcceptanceRemoteBread-writecurrentEDD Series card Port VLAN Configuration : Port1 - Ingress Acceptance 0: Tagged and untagged 1: Tagged only 2: Untagged only
1.3.6.1.4.1.4756.20.442.20.1.731ColumneddPort1VlanEgressTaggingRemoteBread-writecurrentEDD Series card Port VLAN Configuration : Port1 - Egress Tagging 0: Untag port vlan 1: Tag all 2: Untag all
1.3.6.1.4.1.4756.20.442.20.1.732ColumneddPort1AllowedVLANSRemoteBread-writecurrentEDD Series card Global VLAN Configuration: Port1 - Allowed VLANs By default, only VLAN 1 is enabled. More VLANs may be created by using a list syntax where the…
1.3.6.1.4.1.4756.20.442.20.1.733ColumneddPort1ForbiddenVLANSRemoteBread-writecurrentEDD Series card Global VLAN Configuration: Port1 - Forbidden VLANs By default, the field is left blank, which means that the port may become a member of all po…
1.3.6.1.4.1.4756.20.442.20.1.734ColumneddPort2VlanModeRemoteBread-writecurrentEDD Series card Port VLAN Configuration : Port2 - Mode 0: Access 1: Trunk 2: Hybrid
1.3.6.1.4.1.4756.20.442.20.1.735ColumneddPort2VlanIDRemoteBread-writecurrentEDD Series card Port VLAN Configuration : Port2 - VLAN ID
1.3.6.1.4.1.4756.20.442.20.1.736ColumneddPort2VlanTypeRemoteBread-writecurrentEDD Series card Port VLAN Configuration : Port2 - VLAN Type 0: Unaware 1: C-port 2: S-port 3: S-custom-port
1.3.6.1.4.1.4756.20.442.20.1.737ColumneddPort2VlanIngressFilteringRemoteBread-writecurrentEDD Series card Port VLAN Configuration : Port2 - Ingress Filtering 0: Off 1: On
1.3.6.1.4.1.4756.20.442.20.1.738ColumneddPort2VlanIngressAcceptanceRemoteBread-writecurrentEDD Series card Port VLAN Configuration : Por2 - Ingress Acceptance 0: Tagged and untagged 1: Tagged only 2: Untagged only
1.3.6.1.4.1.4756.20.442.20.1.739ColumneddPort2VlanEgressTaggingRemoteBread-writecurrentEDD Series card Port VLAN Configuration : Port2 - Egress Tagging 0: Untag port vlan 1: Tag all 2: Untag all
1.3.6.1.4.1.4756.20.442.20.1.740ColumneddPort2AllowedVLANSRemoteBread-writecurrentEDD Series card Global VLAN Configuration: Port2 - Allowed VLANs By default, only VLAN 1 is enabled. More VLANs may be created by using a list syntax where the…
1.3.6.1.4.1.4756.20.442.20.1.741ColumneddPort2ForbiddenVLANSRemoteBread-writecurrentEDD Series card Global VLAN Configuration: Port2 - Forbidden VLANs By default, the field is left blank, which means that the port may become a member of all po…
1.3.6.1.4.1.4756.20.442.20.1.742ColumneddPort3VlanModeRemoteBread-writecurrentEDD Series card Port VLAN Configuration : Port3 - Mode 0: Access 1: Trunk 2: Hybrid
1.3.6.1.4.1.4756.20.442.20.1.743ColumneddPort3VlanIDRemoteBread-writecurrentEDD Series card Port VLAN Configuration : Port3 - VLAN ID
1.3.6.1.4.1.4756.20.442.20.1.744ColumneddPort3VlanTypeRemoteBread-writecurrentEDD Series card Port VLAN Configuration : Port3 - VLAN Type 0: Unaware 1: C-port 2: S-port 3: S-custom-port
1.3.6.1.4.1.4756.20.442.20.1.745ColumneddPort3VlanIngressFilteringRemoteBread-writecurrentEDD Series card Port VLAN Configuration : Port3 - Ingress Filtering 0: Off 1: On
1.3.6.1.4.1.4756.20.442.20.1.746ColumneddPort3VlanIngressAcceptanceRemoteBread-writecurrentEDD Series card Port VLAN Configuration : Port3 - Ingress Acceptance 0: Tagged and untagged 1: Tagged only 2: Untagged only
1.3.6.1.4.1.4756.20.442.20.1.747ColumneddPort3VlanEgressTaggingRemoteBread-writecurrentEDD Series card Port VLAN Configuration : Port3 - Egress Tagging 0: Untag port vlan 1: Tag all 2: Untag all
1.3.6.1.4.1.4756.20.442.20.1.748ColumneddPort3AllowedVLANSRemoteBread-writecurrentEDD Series card Global VLAN Configuration: Port3 - Allowed VLANs By default, only VLAN 1 is enabled. More VLANs may be created by using a list syntax where the…
1.3.6.1.4.1.4756.20.442.20.1.749ColumneddPort3ForbiddenVLANSRemoteBread-writecurrentEDD Series card Global VLAN Configuration: Port3 - Forbidden VLANs By default, the field is left blank, which means that the port may become a member of all po…
1.3.6.1.4.1.4756.20.442.20.1.750ColumneddPort4VlanModeRemoteBread-writecurrentEDD Series card Port VLAN Configuration : Port4 - Mode 0: Access 1: Trunk 2: Hybrid
1.3.6.1.4.1.4756.20.442.20.1.751ColumneddPort4VlanIDRemoteBread-writecurrentEDD Series card Port VLAN Configuration : Port4 - VLAN ID
1.3.6.1.4.1.4756.20.442.20.1.752ColumneddPort4VlanTypeRemoteBread-writecurrentEDD Series card Port VLAN Configuration : Port4 - VLAN Type 0: Unaware 1: C-port 2: S-port 3: S-custom-port
1.3.6.1.4.1.4756.20.442.20.1.753ColumneddPort4VlanIngressFilteringRemoteBread-writecurrentEDD Series card Port VLAN Configuration : Port4 - Ingress Filtering 0: Off 1: On
1.3.6.1.4.1.4756.20.442.20.1.754ColumneddPort4VlanIngressAcceptanceRemoteBread-writecurrentEDD Series card Port VLAN Configuration : Port4 - Ingress Acceptance 0: Tagged and untagged 1: Tagged only 2: Untagged only
1.3.6.1.4.1.4756.20.442.20.1.755ColumneddPort4VlanEgressTaggingRemoteBread-writecurrentEDD Series card Port VLAN Configuration : Port4 - Egress Tagging 0: Untag port vlan 1: Tag all 2: Untag all
1.3.6.1.4.1.4756.20.442.20.1.756ColumneddPort4AllowedVLANSRemoteBread-writecurrentEDD Series card Global VLAN Configuration: Port4 - Allowed VLANs By default, only VLAN 1 is enabled. More VLANs may be created by using a list syntax where the…
1.3.6.1.4.1.4756.20.442.20.1.757ColumneddPort4ForbiddenVLANSRemoteBread-writecurrentEDD Series card Global VLAN Configuration: Port4 - Forbidden VLANs By default, the field is left blank, which means that the port may become a member of all po…
1.3.6.1.4.1.4756.20.442.20.1.758ColumneddDNSServerTypeRemoteBread-writecurrentEDD Series card IP Configuration: This setting controls the DNS name resolution done by the switch. The following modes are supported: 1:From any DHCP interfac…
1.3.6.1.4.1.4756.20.442.20.1.759ColumneddDNSServerSettingRemoteBread-writecurrentEDD Series card IP Configuration: If iDNSServerType setting '3:Configured',this value must setting IP address format as below: Dotted Decimal Notation refers t…
1.3.6.1.4.1.4756.20.442.20.1.760ColumneddDNSproxyRemoteBread-writecurrentEDD Series card IP Configuration: When DNS proxy is enabled, system will relay DNS requests to the currently configured DNS server, and reply as a DNS resolver…
1.3.6.1.4.1.4756.20.442.20.1.761ColumneddAddIPV4InterfaceRemoteBread-writecurrentEDD Series card IP Interfaces: Add a new IP VLAN Interface: Syntax: [<Interface>] [<vlan_list>] [<IPV4_Addr>] [<IPV4_MASK>] Interface : 1~4
1.3.6.1.4.1.4756.20.442.20.1.762ColumneddDeleteInterfaceRemoteBread-writecurrentEDD Series card IP Interfaces: Delete a IPv4/v6 VLAN Interface: Syntax: [<Interface>] Interface: 1~4
1.3.6.1.4.1.4756.20.442.20.1.763ColumneddIPInterface1VLANRemoteBread-onlycurrentEDD Series card IP Interfaces: The VLAN associated with the IP interface. Only ports in this VLAN will be able to access the IP interface. This field is only a…
1.3.6.1.4.1.4756.20.442.20.1.764ColumneddIPInterface1DHCPRemoteBread-writecurrentEDD Series card IP Interfaces: DHCP
1.3.6.1.4.1.4756.20.442.20.1.765ColumneddIPInterface1FallbackRemoteBread-writecurrentEDD Series card IP Interfaces: Fallback
1.3.6.1.4.1.4756.20.442.20.1.766ColumneddIPInterface1IPV4AddressRemoteBread-onlycurrentEDD Series card IP Interfaces: IPV4 Address
1.3.6.1.4.1.4756.20.442.20.1.767ColumneddIPInterface1IPV4MASKLenRemoteBread-onlycurrentEDD Series card IP Interfaces: IPV4 MASK Length
1.3.6.1.4.1.4756.20.442.20.1.768ColumneddIPInterface2VLANRemoteBread-onlycurrentEDD Series card IP Interfaces: The VLAN associated with the IP interface. Only ports in this VLAN will be able to access the IP interface. This field is only a…
1.3.6.1.4.1.4756.20.442.20.1.769ColumneddIPInterface2DHCPRemoteBread-writecurrentEDD Series card IP Interfaces: DHCP
1.3.6.1.4.1.4756.20.442.20.1.770ColumneddIPInterface2FallbackRemoteBread-writecurrentEDD Series card IP Interfaces: Fallback
1.3.6.1.4.1.4756.20.442.20.1.771ColumneddIPInterface2IPV4AddressRemoteBread-onlycurrentEDD Series card IP Interfaces: IPV4 Address
1.3.6.1.4.1.4756.20.442.20.1.772ColumneddIPInterface2IPV4MASKLenRemoteBread-onlycurrentEDD Series card IP Interfaces: IPV4 MASK Length
1.3.6.1.4.1.4756.20.442.20.1.773ColumneddIPInterface3VLANRemoteBread-onlycurrentEDD Series card IP Interfaces: The VLAN associated with the IP interface. Only ports in this VLAN will be able to access the IP interface. This field is only a…
1.3.6.1.4.1.4756.20.442.20.1.774ColumneddIPInterface3DHCPRemoteBread-writecurrentEDD Series card IP Interfaces: DHCP
1.3.6.1.4.1.4756.20.442.20.1.775ColumneddIPInterface3FallbackRemoteBread-writecurrentEDD Series card IP Interfaces: Fallback
1.3.6.1.4.1.4756.20.442.20.1.776ColumneddIPInterface3IPV4AddressRemoteBread-onlycurrentEDD Series card IP Interfaces: IPV4 Address
1.3.6.1.4.1.4756.20.442.20.1.777ColumneddIPInterface3IPV4MASKLenRemoteBread-onlycurrentEDD Series card IP Interfaces: IPV4 MASK Length
1.3.6.1.4.1.4756.20.442.20.1.778ColumneddIPInterface4VLANRemoteBread-onlycurrentEDD Series card IP Interfaces: The VLAN associated with the IP interface. Only ports in this VLAN will be able to access the IP interface. This field is only a…
1.3.6.1.4.1.4756.20.442.20.1.779ColumneddIPInterface4DHCPRemoteBread-writecurrentEDD Series card IP Interfaces: DHCP
1.3.6.1.4.1.4756.20.442.20.1.780ColumneddIPInterface4FallbackRemoteBread-writecurrentEDD Series card IP Interfaces: Fallback
1.3.6.1.4.1.4756.20.442.20.1.781ColumneddIPInterface4IPV4AddressRemoteBread-onlycurrentEDD Series card IP Interfaces: IPV4 Address
1.3.6.1.4.1.4756.20.442.20.1.782ColumneddIPInterface4IPV4MASKLenRemoteBread-onlycurrentEDD Series card IP Interfaces: IPV4 MASK Length
1.3.6.1.4.1.4756.20.442.20.1.783ColumneddAddIPV6InterfaceRemoteBread-writecurrentEDD Series card IP Interfaces: Add a new IPv6 VLAN Interface: Syntax: [<Interface>] [<vlan_list>] [<IPV4_Addr>] [<IPV4_MASK>] Interface : 1~4
1.3.6.1.4.1.4756.20.442.20.1.784ColumneddIPInterface1IPV6AddressRemoteBread-onlycurrentEDD Series card IP Interfaces: IPV6 Address
1.3.6.1.4.1.4756.20.442.20.1.785ColumneddIPInterface1IPV6MASKLenRemoteBread-onlycurrentEDD Series card IP Interfaces: IPV6 MASK Length
1.3.6.1.4.1.4756.20.442.20.1.786ColumneddIPInterface2IPV6AddressRemoteBread-onlycurrentEDD Series card IP Interfaces: IPV6 Address
1.3.6.1.4.1.4756.20.442.20.1.787ColumneddIPInterface2IPV6MASKLenRemoteBread-onlycurrentEDD Series card IP Interfaces: IPV6 MASK Length
1.3.6.1.4.1.4756.20.442.20.1.788ColumneddIPInterface3IPV6AddressRemoteBread-onlycurrentEDD Series card IP Interfaces: IPV6 Address
1.3.6.1.4.1.4756.20.442.20.1.789ColumneddIPInterface3IPV6MASKLenRemoteBread-onlycurrentEDD Series card IP Interfaces: IPV6 MASK Length
1.3.6.1.4.1.4756.20.442.20.1.790ColumneddIPInterface4IPV6AddressRemoteBread-onlycurrentEDD Series card IP Interfaces: IPV6 Address
1.3.6.1.4.1.4756.20.442.20.1.791ColumneddIPInterface4IPV6MASKLenRemoteBread-onlycurrentEDD Series card IP Interfaces: IPV6 MASK Length
1.3.6.1.4.1.4756.20.442.20.1.792ColumneddPort1ALSRemoteBread-writecurrentEDD Series card Port1 auto laser shutdown: 0: Disable 1: Enable
1.3.6.1.4.1.4756.20.442.20.1.793ColumneddPort2ALSRemoteBread-writecurrentEDD Series card Port2 auto laser shutdown: 0: Disable 1: Enable
1.3.6.1.4.1.4756.20.442.20.1.794ColumneddPort3ALSRemoteBread-writecurrentEDD Series card Port3 auto laser shutdown (MX210 only): 0: Disable 1: Enable
1.3.6.1.4.1.4756.20.442.20.1.795ColumneddPort1LLFLogicRemoteBread-writecurrentEDD Series card Port1 link loss forwarding - Logic 0: AND 1: OR
1.3.6.1.4.1.4756.20.442.20.1.796ColumneddPort1LLFLogicPort2RemoteBread-writecurrentEDD Series card Port1 link loss forwarding - Link/Rx Loss Port2 0: NO 1: YES
1.3.6.1.4.1.4756.20.442.20.1.797ColumneddPort1LLFLogicPort3RemoteBread-writecurrentEDD Series card Port1 link loss forwarding - Link/Rx Loss Port3 0: NO 1: YES
1.3.6.1.4.1.4756.20.442.20.1.798ColumneddPort1LLFLogicPort4RemoteBread-writecurrentEDD Series card Port1 link loss forwarding - Link/Rx Loss Port4 0: NO 1: YES
1.3.6.1.4.1.4756.20.442.20.1.799ColumneddPort2LLFLogicRemoteBread-writecurrentEDD Series card Port2 link loss forwarding - Logic 0: AND 1: OR
1.3.6.1.4.1.4756.20.442.20.1.800ColumneddPort2LLFLogicPort1RemoteBread-writecurrentEDD Series card Port2 link loss forwarding - Link/Rx Loss Port1 0: NO 1: YES
1.3.6.1.4.1.4756.20.442.20.1.801ColumneddPort2LLFLogicPort3RemoteBread-writecurrentEDD Series card Port2 link loss forwarding - Link/Rx Loss Port3 0: NO 1: YES
1.3.6.1.4.1.4756.20.442.20.1.802ColumneddPort2LLFLogicPort4RemoteBread-writecurrentEDD Series card Port2 link loss forwarding - Link/Rx Loss Port4 0: NO 1: YES
1.3.6.1.4.1.4756.20.442.20.1.803ColumneddPort3LLFLogicRemoteBread-writecurrentEDD Series card Port1 link loss forwarding - Logic 0: AND 1: OR
1.3.6.1.4.1.4756.20.442.20.1.804ColumneddPort3LLFLogicPort1RemoteBread-writecurrentEDD Series card Port3 link loss forwarding - Link/Rx Loss Port1 0: NO 1: YES
1.3.6.1.4.1.4756.20.442.20.1.805ColumneddPort3LLFLogicPort2RemoteBread-writecurrentEDD Series card Port3 link loss forwarding - Link/Rx Loss Port2 0: NO 1: YES
1.3.6.1.4.1.4756.20.442.20.1.806ColumneddPort3LLFLogicPort4RemoteBread-writecurrentEDD Series card Port3 link loss forwarding - Link/Rx Loss Port4 0: NO 1: YES
1.3.6.1.4.1.4756.20.442.20.1.807ColumneddPort4LLFLogicRemoteBread-writecurrentEDD Series card Port4 link loss forwarding - Logic 0: AND 1: OR
1.3.6.1.4.1.4756.20.442.20.1.808ColumneddPort4LLFLogicPort1RemoteBread-writecurrentEDD Series card Port4 link loss forwarding - Link/Rx Loss Port1 0: NO 1: YES
1.3.6.1.4.1.4756.20.442.20.1.809ColumneddPort4LLFLogicPort2RemoteBread-writecurrentEDD Series card Port4 link loss forwarding - Link/Rx Loss Port2 0: NO 1: YES
1.3.6.1.4.1.4756.20.442.20.1.810ColumneddPort4LLFLogicPort3RemoteBread-writecurrentEDD Series card Port4 link loss forwarding - Link/Rx Loss Port3 0: NO 1: YES
1.3.6.1.4.1.4756.20.442.20.1.811ColumneddQOSPort1IngressRemoteBread-writecurrentEDD Series card QOS Port1 Ingress Enabled 0: NO 1: YES
1.3.6.1.4.1.4756.20.442.20.1.812ColumneddQOSPort1IngressRateRemoteBread-writecurrentEDD Series card QOS Port1 Ingress Rate
1.3.6.1.4.1.4756.20.442.20.1.813ColumneddQOSPort1IngressRateUnitRemoteBread-writecurrentEDD Series card QOS Port1 Ingress Rate Unit 0: Kbps 1: Mbps 2: fps 3: kfps
1.3.6.1.4.1.4756.20.442.20.1.814ColumneddQOSPort1IngressFlowControlRemoteBread-writecurrentEDD Series card QOS Port1 Ingress Flow Control 0: NO 1: YES
1.3.6.1.4.1.4756.20.442.20.1.815ColumneddQOSPort2IngressRemoteBread-writecurrentEDD Series card QOS Port2 Ingress Enabled 0: NO 1: YES
1.3.6.1.4.1.4756.20.442.20.1.816ColumneddQOSPort2IngressRateRemoteBread-writecurrentEDD Series card QOS Port2 Ingress Rate
1.3.6.1.4.1.4756.20.442.20.1.817ColumneddQOSPort2IngressRateUnitRemoteBread-writecurrentEDD Series card QOS Port2 Ingress Rate Unit 0: Kbps 1: Mbps 2: fps 3: kfps
1.3.6.1.4.1.4756.20.442.20.1.818ColumneddQOSPort2IngressFlowControlRemoteBread-writecurrentEDD Series card QOS Port2 Ingress Flow Control 0: NO 1: YES
1.3.6.1.4.1.4756.20.442.20.1.819ColumneddQOSPort3IngressRemoteBread-writecurrentEDD Series card QOS Port3 Ingress Enabled 0: NO 1: YES
1.3.6.1.4.1.4756.20.442.20.1.820ColumneddQOSPort3IngressRateRemoteBread-writecurrentEDD Series card QOS Port3 Ingress Rate
1.3.6.1.4.1.4756.20.442.20.1.821ColumneddQOSPort3IngressRateUnitRemoteBread-writecurrentEDD Series card QOS Port3 Ingress Rate Unit 0: Kbps 1: Mbps 2: fps 3: kfps
1.3.6.1.4.1.4756.20.442.20.1.822ColumneddQOSPort3IngressFlowControlRemoteBread-writecurrentEDD Series card QOS Port3 Ingress Flow Control 0: NO 1: YES
1.3.6.1.4.1.4756.20.442.20.1.823ColumneddQOSPort4IngressRemoteBread-writecurrentEDD Series card QOS Port4 Ingress Enabled 0: NO 1: YES
1.3.6.1.4.1.4756.20.442.20.1.824ColumneddQOSPort4IngressRateRemoteBread-writecurrentEDD Series card QOS Port4 Ingress Rate
1.3.6.1.4.1.4756.20.442.20.1.825ColumneddQOSPort4IngressRateUnitRemoteBread-writecurrentEDD Series card QOS Port4 Ingress Rate Unit 0: Kbps 1: Mbps 2: fps 3: kfps
1.3.6.1.4.1.4756.20.442.20.1.826ColumneddQOSPort4IngressFlowControlRemoteBread-writecurrentEDD Series card QOS Port4 Ingress Flow Control 0: NO 1: YES
1.3.6.1.4.1.4756.20.442.20.1.827ColumneddQOSPort1EgressRemoteBread-writecurrentEDD Series card QOS Port1 Egress Enabled 0: NO 1: YES
1.3.6.1.4.1.4756.20.442.20.1.828ColumneddQOSPort1EgressRateRemoteBread-writecurrentEDD Series card QOS Port1 Egress Rate
1.3.6.1.4.1.4756.20.442.20.1.829ColumneddQOSPort1EgressRateUnitRemoteBread-writecurrentEDD Series card QOS Port1 Egress Rate Unit 0: Kbps 1: Mbps
1.3.6.1.4.1.4756.20.442.20.1.830ColumneddQOSPort2EgressRemoteBread-writecurrentEDD Series card QOS Port2 Egress Enabled 0: NO 1: YES
1.3.6.1.4.1.4756.20.442.20.1.831ColumneddQOSPort2EgressRateRemoteBread-writecurrentEDD Series card QOS Port2 Egress Rate
1.3.6.1.4.1.4756.20.442.20.1.832ColumneddQOSPort2EgressRateUnitRemoteBread-writecurrentEDD Series card QOS Port2 Egress Rate Unit 0: Kbps 1: Mbps
1.3.6.1.4.1.4756.20.442.20.1.833ColumneddQOSPort3EgressRemoteBread-writecurrentEDD Series card QOS Port3 Egress Enabled 0: NO 1: YES
1.3.6.1.4.1.4756.20.442.20.1.834ColumneddQOSPort3EgressRateRemoteBread-writecurrentEDD Series card QOS Port3 Egress Rate
1.3.6.1.4.1.4756.20.442.20.1.835ColumneddQOSPort3EgressRateUnitRemoteBread-writecurrentEDD Series card QOS Port3 Egress Rate Unit 0: Kbps 1: Mbps
1.3.6.1.4.1.4756.20.442.20.1.836ColumneddQOSPort4EgressRemoteBread-writecurrentEDD Series card QOS Port4 Egress Enabled 0: NO 1: YES
1.3.6.1.4.1.4756.20.442.20.1.837ColumneddQOSPort4EgressRateRemoteBread-writecurrentEDD Series card QOS Port4 Egress Rate
1.3.6.1.4.1.4756.20.442.20.1.838ColumneddQOSPort4EgressRateUnitRemoteBread-writecurrentEDD Series card QOS Port4 Egress Rate Unit 0: Kbps 1: Mbps
1.3.6.1.4.1.4756.20.442.20.1.839ColumneddQOSUnicastRemoteBread-writecurrentEDD Series card QOS Storm Control Configuration- Unicast 0: NO 1: YES
1.3.6.1.4.1.4756.20.442.20.1.840ColumneddQOSUnicastRateRemoteBread-writecurrentEDD Series card QOS Storm Control Configuration- Unicast Rate The rate unit is packets per second (pps). 0: 1 1: 2 2: 4 3: 8 4: 16 5: 32 6: 64 7: 128 8: 256 9:…
1.3.6.1.4.1.4756.20.442.20.1.841ColumneddQOSMulticastRemoteBread-writecurrentEDD Series card QOS Storm Control Configuration- Multicast 0: NO 1: YES
1.3.6.1.4.1.4756.20.442.20.1.842ColumneddQOSMulticastRateRemoteBread-writecurrentEDD Series card QOS Storm Control Configuration- Multicast The rate unit is packets per second (pps). 0: 1 1: 2 2: 4 3: 8 4: 16 5: 32 6: 64 7: 128 8: 256 9: 51…
1.3.6.1.4.1.4756.20.442.20.1.843ColumneddQOSBroadcastRemoteBread-writecurrentEDD Series card QOS Storm Control Configuration- Broadcast 0: NO 1: YES
1.3.6.1.4.1.4756.20.442.20.1.844ColumneddQOSBroadcastRateRemoteBread-writecurrentEDD Series card QOS Storm Control Configuration- Broadcast The rate unit is packets per second (pps). 0: 1 1: 2 2: 4 3: 8 4: 16 5: 32 6: 64 7: 128 8: 256 9: 51…
1.3.6.1.4.1.4756.20.442.20.1.845ColumneddL2CPPort1DMAC0180C2000000RemoteBread-writecurrentEDD Series card Port 1 L2CP Mode 0180C2000000 0: Forward 1: Peer
1.3.6.1.4.1.4756.20.442.20.1.846ColumneddL2CPPort1DMAC0180C2000001RemoteBread-writecurrentEDD Series card Port 1 L2CP Mode 0180C2000001 0: Forward 1: Peer
1.3.6.1.4.1.4756.20.442.20.1.847ColumneddL2CPPort1DMAC0180C2000002RemoteBread-writecurrentEDD Series card Port 1 L2CP Mode 0180C2000002 0: Forward 1: Peer
1.3.6.1.4.1.4756.20.442.20.1.848ColumneddL2CPPort1DMAC0180C2000003RemoteBread-writecurrentEDD Series card Port 1 L2CP Mode 0180C2000003 0: Forward 1: Peer
1.3.6.1.4.1.4756.20.442.20.1.849ColumneddL2CPPort1DMAC0180C2000004RemoteBread-writecurrentEDD Series card Port 1 L2CP Mode 0180C2000004 0: Forward 1: Peer
1.3.6.1.4.1.4756.20.442.20.1.850ColumneddL2CPPort1DMAC0180C2000005RemoteBread-writecurrentEDD Series card Port 1 L2CP Mode 0180C2000005 0: Forward 1: Peer
1.3.6.1.4.1.4756.20.442.20.1.851ColumneddL2CPPort1DMAC0180C2000006RemoteBread-writecurrentEDD Series card Port 1 L2CP Mode 0180C2000006 0: Forward 1: Peer
1.3.6.1.4.1.4756.20.442.20.1.852ColumneddL2CPPort1DMAC0180C2000007RemoteBread-writecurrentEDD Series card Port 1 L2CP Mode 0180C2000007 0: Forward 1: Peer
1.3.6.1.4.1.4756.20.442.20.1.853ColumneddL2CPPort1DMAC0180C2000008RemoteBread-writecurrentEDD Series card Port 1 L2CP Mode 0180C2000008 0: Forward 1: Peer
1.3.6.1.4.1.4756.20.442.20.1.854ColumneddL2CPPort1DMAC0180C2000009RemoteBread-writecurrentEDD Series card Port 1 L2CP Mode 0180C2000009 0: Forward 1: Peer
1.3.6.1.4.1.4756.20.442.20.1.855ColumneddL2CPPort1DMAC0180C200000ARemoteBread-writecurrentEDD Series card Port 1 L2CP Mode 0180C200000A 0: Forward 1: Peer
1.3.6.1.4.1.4756.20.442.20.1.856ColumneddL2CPPort1DMAC0180C200000BRemoteBread-writecurrentEDD Series card Port 1 L2CP Mode 0180C200000B 0: Forward 1: Peer
1.3.6.1.4.1.4756.20.442.20.1.857ColumneddL2CPPort1DMAC0180C200000CRemoteBread-writecurrentEDD Series card Port 1 L2CP Mode 0180C200000C 0: Forward 1: Peer
1.3.6.1.4.1.4756.20.442.20.1.858ColumneddL2CPPort1DMAC0180C200000DRemoteBread-writecurrentEDD Series card Port 1 L2CP Mode 0180C200000D 0: Forward 1: Peer
1.3.6.1.4.1.4756.20.442.20.1.859ColumneddL2CPPort1DMAC0180C200000ERemoteBread-writecurrentEDD Series card Port 1 L2CP Mode 0180C200000E 0: Forward 1: Peer
1.3.6.1.4.1.4756.20.442.20.1.860ColumneddL2CPPort1DMAC0180C200000FRemoteBread-writecurrentEDD Series card Port 1 L2CP Mode 0180C200000F 0: Forward 1: Peer
1.3.6.1.4.1.4756.20.442.20.1.861ColumneddL2CPPort1DMAC0180C2000010RemoteBread-writecurrentEDD Series card Port 1 L2CP Mode 0180C2000010 0: Forward 1: Peer
1.3.6.1.4.1.4756.20.442.20.1.862ColumneddL2CPPort1DMAC0180C2000020RemoteBread-writecurrentEDD Series card Port 1 L2CP Mode 0180C2000020 0: Forward 1: Peer
1.3.6.1.4.1.4756.20.442.20.1.863ColumneddL2CPPort1DMAC0180C2000021RemoteBread-writecurrentEDD Series card Port 1 L2CP Mode 0180C2000021 0: Forward 1: Peer
1.3.6.1.4.1.4756.20.442.20.1.864ColumneddL2CPPort1DMAC0180C2000022RemoteBread-writecurrentEDD Series card Port 1 L2CP Mode 0180C2000022 0: Forward 1: Peer
1.3.6.1.4.1.4756.20.442.20.1.865ColumneddL2CPPort1DMAC0180C2000023RemoteBread-writecurrentEDD Series card Port 1 L2CP Mode 0180C2000023 0: Forward 1: Peer
1.3.6.1.4.1.4756.20.442.20.1.866ColumneddL2CPPort1DMAC0180C2000024RemoteBread-writecurrentEDD Series card Port 1 L2CP Mode 0180C2000024 0: Forward 1: Peer
1.3.6.1.4.1.4756.20.442.20.1.867ColumneddL2CPPort1DMAC0180C2000025RemoteBread-writecurrentEDD Series card Port 1 L2CP Mode 0180C2000025 0: Forward 1: Peer
1.3.6.1.4.1.4756.20.442.20.1.868ColumneddL2CPPort1DMAC0180C2000026RemoteBread-writecurrentEDD Series card Port 1 L2CP Mode 0180C2000026 0: Forward 1: Peer
1.3.6.1.4.1.4756.20.442.20.1.869ColumneddL2CPPort1DMAC0180C2000027RemoteBread-writecurrentEDD Series card Port 1 L2CP Mode 0180C2000027 0: Forward 1: Peer
1.3.6.1.4.1.4756.20.442.20.1.870ColumneddL2CPPort1DMAC0180C2000028RemoteBread-writecurrentEDD Series card Port 1 L2CP Mode 0180C2000028 0: Forward 1: Peer
1.3.6.1.4.1.4756.20.442.20.1.871ColumneddL2CPPort1DMAC0180C2000029RemoteBread-writecurrentEDD Series card Port 1 L2CP Mode 0180C2000029 0: Forward 1: Peer
1.3.6.1.4.1.4756.20.442.20.1.872ColumneddL2CPPort1DMAC0180C200002ARemoteBread-writecurrentEDD Series card Port 1 L2CP Mode 0180C200002A 0: Forward 1: Peer
1.3.6.1.4.1.4756.20.442.20.1.873ColumneddL2CPPort1DMAC0180C200002BRemoteBread-writecurrentEDD Series card Port 1 L2CP Mode 0180C200002B 0: Forward 1: Peer
1.3.6.1.4.1.4756.20.442.20.1.874ColumneddL2CPPort1DMAC0180C200002CRemoteBread-writecurrentEDD Series card Port 1 L2CP Mode 0180C200002C 0: Forward 1: Peer
1.3.6.1.4.1.4756.20.442.20.1.875ColumneddL2CPPort1DMAC0180C200002DRemoteBread-writecurrentEDD Series card Port 1 L2CP Mode 0180C200002D 0: Forward 1: Peer
1.3.6.1.4.1.4756.20.442.20.1.876ColumneddL2CPPort1DMAC0180C200002ERemoteBread-writecurrentEDD Series card Port 1 L2CP Mode 0180C200002E 0: Forward 1: Peer
1.3.6.1.4.1.4756.20.442.20.1.877ColumneddL2CPPort1DMAC0180C200002FRemoteBread-writecurrentEDD Series card Port 1 L2CP Mode 0180C200002F 0: Forward 1: Peer
1.3.6.1.4.1.4756.20.442.20.1.878ColumneddL2CPPort2DMAC0180C2000000RemoteBread-writecurrentEDD Series card Port 2 L2CP Mode 0180C2000000 0: Forward 1: Peer
1.3.6.1.4.1.4756.20.442.20.1.879ColumneddL2CPPort2DMAC0180C2000001RemoteBread-writecurrentEDD Series card Port 2 L2CP Mode 0180C2000001 0: Forward 1: Peer
1.3.6.1.4.1.4756.20.442.20.1.880ColumneddL2CPPort2DMAC0180C2000002RemoteBread-writecurrentEDD Series card Port 2 L2CP Mode 0180C2000002 0: Forward 1: Peer
1.3.6.1.4.1.4756.20.442.20.1.881ColumneddL2CPPort2DMAC0180C2000003RemoteBread-writecurrentEDD Series card Port 2 L2CP Mode 0180C2000003 0: Forward 1: Peer
1.3.6.1.4.1.4756.20.442.20.1.882ColumneddL2CPPort2DMAC0180C2000004RemoteBread-writecurrentEDD Series card Port 2 L2CP Mode 0180C2000004 0: Forward 1: Peer
1.3.6.1.4.1.4756.20.442.20.1.883ColumneddL2CPPort2DMAC0180C2000005RemoteBread-writecurrentEDD Series card Port 2 L2CP Mode 0180C2000005 0: Forward 1: Peer
1.3.6.1.4.1.4756.20.442.20.1.884ColumneddL2CPPort2DMAC0180C2000006RemoteBread-writecurrentEDD Series card Port 2 L2CP Mode 0180C2000006 0: Forward 1: Peer
1.3.6.1.4.1.4756.20.442.20.1.885ColumneddL2CPPort2DMAC0180C2000007RemoteBread-writecurrentEDD Series card Port 2 L2CP Mode 0180C2000007 0: Forward 1: Peer
1.3.6.1.4.1.4756.20.442.20.1.886ColumneddL2CPPort2DMAC0180C2000008RemoteBread-writecurrentEDD Series card Port 2 L2CP Mode 0180C2000008 0: Forward 1: Peer
1.3.6.1.4.1.4756.20.442.20.1.887ColumneddL2CPPort2DMAC0180C2000009RemoteBread-writecurrentEDD Series card Port 2 L2CP Mode 0180C2000009 0: Forward 1: Peer
1.3.6.1.4.1.4756.20.442.20.1.888ColumneddL2CPPort2DMAC0180C200000ARemoteBread-writecurrentEDD Series card Port 2 L2CP Mode 0180C200000A 0: Forward 1: Peer
1.3.6.1.4.1.4756.20.442.20.1.889ColumneddL2CPPort2DMAC0180C200000BRemoteBread-writecurrentEDD Series card Port 2 L2CP Mode 0180C200000B 0: Forward 1: Peer
1.3.6.1.4.1.4756.20.442.20.1.890ColumneddL2CPPort2DMAC0180C200000CRemoteBread-writecurrentEDD Series card Port 2 L2CP Mode 0180C200000C 0: Forward 1: Peer
1.3.6.1.4.1.4756.20.442.20.1.891ColumneddL2CPPort2DMAC0180C200000DRemoteBread-writecurrentEDD Series card Port 2 L2CP Mode 0180C200000A 0: Forward 1: Peer
1.3.6.1.4.1.4756.20.442.20.1.892ColumneddL2CPPort2DMAC0180C200000ERemoteBread-writecurrentEDD Series card Port 2 L2CP Mode 0180C200000E 0: Forward 1: Peer
1.3.6.1.4.1.4756.20.442.20.1.893ColumneddL2CPPort2DMAC0180C200000FRemoteBread-writecurrentEDD Series card Port 2 L2CP Mode 0180C200000F 0: Forward 1: Peer
1.3.6.1.4.1.4756.20.442.20.1.894ColumneddL2CPPort2DMAC0180C2000010RemoteBread-writecurrentEDD Series card Port 2 L2CP Mode 0180C2000010 0: Forward 1: Peer
1.3.6.1.4.1.4756.20.442.20.1.895ColumneddL2CPPort2DMAC0180C2000020RemoteBread-writecurrentEDD Series card Port 2 L2CP Mode 0180C2000020 0: Forward 1: Peer
1.3.6.1.4.1.4756.20.442.20.1.896ColumneddL2CPPort2DMAC0180C2000021RemoteBread-writecurrentEDD Series card Port 2 L2CP Mode 0180C2000021 0: Forward 1: Peer
1.3.6.1.4.1.4756.20.442.20.1.897ColumneddL2CPPort2DMAC0180C2000022RemoteBread-writecurrentEDD Series card Port 2 L2CP Mode 0180C2000022 0: Forward 1: Peer
1.3.6.1.4.1.4756.20.442.20.1.898ColumneddL2CPPort2DMAC0180C2000023RemoteBread-writecurrentEDD Series card Port 2 L2CP Mode 0180C2000023 0: Forward 1: Peer
1.3.6.1.4.1.4756.20.442.20.1.899ColumneddL2CPPort2DMAC0180C2000024RemoteBread-writecurrentEDD Series card Port 2 L2CP Mode 0180C2000024 0: Forward 1: Peer
1.3.6.1.4.1.4756.20.442.20.1.900ColumneddL2CPPort2DMAC0180C2000025RemoteBread-writecurrentEDD Series card Port 2 L2CP Mode 0180C2000025 0: Forward 1: Peer
1.3.6.1.4.1.4756.20.442.20.1.901ColumneddL2CPPort2DMAC0180C2000026RemoteBread-writecurrentEDD Series card Port 2 L2CP Mode 0180C2000026 0: Forward 1: Peer
1.3.6.1.4.1.4756.20.442.20.1.902ColumneddL2CPPort2DMAC0180C2000027RemoteBread-writecurrentEDD Series card Port 2 L2CP Mode 0180C2000027 0: Forward 1: Peer
1.3.6.1.4.1.4756.20.442.20.1.903ColumneddL2CPPort2DMAC0180C2000028RemoteBread-writecurrentEDD Series card Port 2 L2CP Mode 0180C2000028 0: Forward 1: Peer
1.3.6.1.4.1.4756.20.442.20.1.904ColumneddL2CPPort2DMAC0180C2000029RemoteBread-writecurrentEDD Series card Port 2 L2CP Mode 0180C2000029 0: Forward 1: Peer
1.3.6.1.4.1.4756.20.442.20.1.905ColumneddL2CPPort2DMAC0180C200002ARemoteBread-writecurrentEDD Series card Port 2 L2CP Mode 0180C200002A 0: Forward 1: Peer
1.3.6.1.4.1.4756.20.442.20.1.906ColumneddL2CPPort2DMAC0180C200002BRemoteBread-writecurrentEDD Series card Port 2 L2CP Mode 0180C200002B 0: Forward 1: Peer
1.3.6.1.4.1.4756.20.442.20.1.907ColumneddL2CPPort2DMAC0180C200002CRemoteBread-writecurrentEDD Series card Port 2 L2CP Mode 0180C200002C 0: Forward 1: Peer
1.3.6.1.4.1.4756.20.442.20.1.908ColumneddL2CPPort2DMAC0180C200002DRemoteBread-writecurrentEDD Series card Port 2 L2CP Mode 0180C200002D 0: Forward 1: Peer
1.3.6.1.4.1.4756.20.442.20.1.909ColumneddL2CPPort2DMAC0180C200002ERemoteBread-writecurrentEDD Series card Port 2 L2CP Mode 0180C200002E 0: Forward 1: Peer
1.3.6.1.4.1.4756.20.442.20.1.910ColumneddL2CPPort2DMAC0180C200002FRemoteBread-writecurrentEDD Series card Port 2 L2CP Mode 0180C200002F 0: Forward 1: Peer
1.3.6.1.4.1.4756.20.442.20.1.911ColumneddL2CPPort3DMAC0180C2000000RemoteBread-writecurrentEDD Series card Port 3 L2CP Mode 0180C2000000 0: Forward 1: Peer
1.3.6.1.4.1.4756.20.442.20.1.912ColumneddL2CPPort3DMAC0180C2000001RemoteBread-writecurrentEDD Series card Port 3 L2CP Mode 0180C2000001 0: Forward 1: Peer
1.3.6.1.4.1.4756.20.442.20.1.913ColumneddL2CPPort3DMAC0180C2000002RemoteBread-writecurrentEDD Series card Port 3 L2CP Mode 0180C2000002 0: Forward 1: Peer
1.3.6.1.4.1.4756.20.442.20.1.914ColumneddL2CPPort3DMAC0180C2000003RemoteBread-writecurrentEDD Series card Port 3 L2CP Mode 0180C2000003 0: Forward 1: Peer
1.3.6.1.4.1.4756.20.442.20.1.915ColumneddL2CPPort3DMAC0180C2000004RemoteBread-writecurrentEDD Series card Port 3 L2CP Mode 0180C2000004 0: Forward 1: Peer
1.3.6.1.4.1.4756.20.442.20.1.916ColumneddL2CPPort3DMAC0180C2000005RemoteBread-writecurrentEDD Series card Port 3 L2CP Mode 0180C2000005 0: Forward 1: Peer
1.3.6.1.4.1.4756.20.442.20.1.917ColumneddL2CPPort3DMAC0180C2000006RemoteBread-writecurrentEDD Series card Port 3 L2CP Mode 0180C2000006 0: Forward 1: Peer
1.3.6.1.4.1.4756.20.442.20.1.918ColumneddL2CPPort3DMAC0180C2000007RemoteBread-writecurrentEDD Series card Port 3 L2CP Mode 0180C2000007 0: Forward 1: Peer
1.3.6.1.4.1.4756.20.442.20.1.919ColumneddL2CPPort3DMAC0180C2000008RemoteBread-writecurrentEDD Series card Port 3 L2CP Mode 0180C2000008 0: Forward 1: Peer
1.3.6.1.4.1.4756.20.442.20.1.920ColumneddL2CPPort3DMAC0180C2000009RemoteBread-writecurrentEDD Series card Port 3 L2CP Mode 0180C2000009 0: Forward 1: Peer
1.3.6.1.4.1.4756.20.442.20.1.921ColumneddL2CPPort3DMAC0180C200000ARemoteBread-writecurrentEDD Series card Port 3 L2CP Mode 0180C200000A 0: Forward 1: Peer
1.3.6.1.4.1.4756.20.442.20.1.922ColumneddL2CPPort3DMAC0180C200000BRemoteBread-writecurrentEDD Series card Port 3 L2CP Mode 0180C200000B 0: Forward 1: Peer
1.3.6.1.4.1.4756.20.442.20.1.923ColumneddL2CPPort3DMAC0180C200000CRemoteBread-writecurrentEDD Series card Port 3 L2CP Mode 0180C200000C 0: Forward 1: Peer
1.3.6.1.4.1.4756.20.442.20.1.924ColumneddL2CPPort3DMAC0180C200000DRemoteBread-writecurrentEDD Series card Port 3 L2CP Mode 0180C200000D 0: Forward 1: Peer
1.3.6.1.4.1.4756.20.442.20.1.925ColumneddL2CPPort3DMAC0180C200000ERemoteBread-writecurrentEDD Series card Port 3 L2CP Mode 0180C200000E 0: Forward 1: Peer
1.3.6.1.4.1.4756.20.442.20.1.926ColumneddL2CPPort3DMAC0180C200000FRemoteBread-writecurrentEDD Series card Port 3 L2CP Mode 0180C200000F 0: Forward 1: Peer
1.3.6.1.4.1.4756.20.442.20.1.927ColumneddL2CPPort3DMAC0180C2000010RemoteBread-writecurrentEDD Series card Port 3 L2CP Mode 0180C2000010 0: Forward 1: Peer
1.3.6.1.4.1.4756.20.442.20.1.928ColumneddL2CPPort3DMAC0180C2000020RemoteBread-writecurrentEDD Series card Port 3 L2CP Mode 0180C2000020 0: Forward 1: Peer
1.3.6.1.4.1.4756.20.442.20.1.929ColumneddL2CPPort3DMAC0180C2000021RemoteBread-writecurrentEDD Series card Port 3 L2CP Mode 0180C2000021 0: Forward 1: Peer
1.3.6.1.4.1.4756.20.442.20.1.930ColumneddL2CPPort3DMAC0180C2000022RemoteBread-writecurrentEDD Series card Port 3 L2CP Mode 0180C2000022 0: Forward 1: Peer
1.3.6.1.4.1.4756.20.442.20.1.931ColumneddL2CPPort3DMAC0180C2000023RemoteBread-writecurrentEDD Series card Port 3 L2CP Mode 0180C2000023 0: Forward 1: Peer
1.3.6.1.4.1.4756.20.442.20.1.932ColumneddL2CPPort3DMAC0180C2000024RemoteBread-writecurrentEDD Series card Port 3 L2CP Mode 0180C2000024 0: Forward 1: Peer
1.3.6.1.4.1.4756.20.442.20.1.933ColumneddL2CPPort3DMAC0180C2000025RemoteBread-writecurrentEDD Series card Port 3 L2CP Mode 0180C2000025 0: Forward 1: Peer
1.3.6.1.4.1.4756.20.442.20.1.934ColumneddL2CPPort3DMAC0180C2000026RemoteBread-writecurrentEDD Series card Port 3 L2CP Mode 0180C2000026 0: Forward 1: Peer
1.3.6.1.4.1.4756.20.442.20.1.935ColumneddL2CPPort3DMAC0180C2000027RemoteBread-writecurrentEDD Series card Port 3 L2CP Mode 0180C2000027 0: Forward 1: Peer
1.3.6.1.4.1.4756.20.442.20.1.936ColumneddL2CPPort3DMAC0180C2000028RemoteBread-writecurrentEDD Series card Port 3 L2CP Mode 0180C2000028 0: Forward 1: Peer
1.3.6.1.4.1.4756.20.442.20.1.937ColumneddL2CPPort3DMAC0180C2000029RemoteBread-writecurrentEDD Series card Port 3 L2CP Mode 0180C2000029 0: Forward 1: Peer
1.3.6.1.4.1.4756.20.442.20.1.938ColumneddL2CPPort3DMAC0180C200002ARemoteBread-writecurrentEDD Series card Port 3 L2CP Mode 0180C200002A 0: Forward 1: Peer
1.3.6.1.4.1.4756.20.442.20.1.939ColumneddL2CPPort3DMAC0180C200002BRemoteBread-writecurrentEDD Series card Port 3 L2CP Mode 0180C200002B 0: Forward 1: Peer
1.3.6.1.4.1.4756.20.442.20.1.940ColumneddL2CPPort3DMAC0180C200002CRemoteBread-writecurrentEDD Series card Port 3 L2CP Mode 0180C200002C 0: Forward 1: Peer
1.3.6.1.4.1.4756.20.442.20.1.941ColumneddL2CPPort3DMAC0180C200002DRemoteBread-writecurrentEDD Series card Port 3 L2CP Mode 0180C200002D 0: Forward 1: Peer
1.3.6.1.4.1.4756.20.442.20.1.942ColumneddL2CPPort3DMAC0180C200002ERemoteBread-writecurrentEDD Series card Port 3 L2CP Mode 0180C200002E 0: Forward 1: Peer
1.3.6.1.4.1.4756.20.442.20.1.943ColumneddL2CPPort3DMAC0180C200002FRemoteBread-writecurrentEDD Series card Port 3 L2CP Mode 0180C200002F 0: Forward 1: Peer
1.3.6.1.4.1.4756.20.442.20.1.944ColumneddL2CPPort4DMAC0180C2000000RemoteBread-writecurrentEDD Series card Port 4 L2CP Mode 0180C2000000 0: Forward 1: Peer
1.3.6.1.4.1.4756.20.442.20.1.945ColumneddL2CPPort4DMAC0180C2000001RemoteBread-writecurrentEDD Series card Port 4 L2CP Mode 0180C2000001 0: Forward 1: Peer
1.3.6.1.4.1.4756.20.442.20.1.946ColumneddL2CPPort4DMAC0180C2000002RemoteBread-writecurrentEDD Series card Port 4 L2CP Mode 0180C2000002 0: Forward 1: Peer
1.3.6.1.4.1.4756.20.442.20.1.947ColumneddL2CPPort4DMAC0180C2000003RemoteBread-writecurrentEDD Series card Port 4 L2CP Mode 0180C2000003 0: Forward 1: Peer
1.3.6.1.4.1.4756.20.442.20.1.948ColumneddL2CPPort4DMAC0180C2000004RemoteBread-writecurrentEDD Series card Port 4 L2CP Mode 0180C2000004 0: Forward 1: Peer
1.3.6.1.4.1.4756.20.442.20.1.949ColumneddL2CPPort4DMAC0180C2000005RemoteBread-writecurrentEDD Series card Port 4 L2CP Mode 0180C2000005 0: Forward 1: Peer
1.3.6.1.4.1.4756.20.442.20.1.950ColumneddL2CPPort4DMAC0180C2000006RemoteBread-writecurrentEDD Series card Port 4 L2CP Mode 0180C2000006 0: Forward 1: Peer
1.3.6.1.4.1.4756.20.442.20.1.951ColumneddL2CPPort4DMAC0180C2000007RemoteBread-writecurrentEDD Series card Port 4 L2CP Mode 0180C2000007 0: Forward 1: Peer
1.3.6.1.4.1.4756.20.442.20.1.952ColumneddL2CPPort4DMAC0180C2000008RemoteBread-writecurrentEDD Series card Port 4 L2CP Mode 0180C2000008 0: Forward 1: Peer
1.3.6.1.4.1.4756.20.442.20.1.953ColumneddL2CPPort4DMAC0180C2000009RemoteBread-writecurrentEDD Series card Port 4 L2CP Mode 0180C2000009 0: Forward 1: Peer
1.3.6.1.4.1.4756.20.442.20.1.954ColumneddL2CPPort4DMAC0180C200000ARemoteBread-writecurrentEDD Series card Port 4 L2CP Mode 0180C200000A 0: Forward 1: Peer
1.3.6.1.4.1.4756.20.442.20.1.955ColumneddL2CPPort4DMAC0180C200000BRemoteBread-writecurrentEDD Series card Port 4 L2CP Mode 0180C200000B 0: Forward 1: Peer
1.3.6.1.4.1.4756.20.442.20.1.956ColumneddL2CPPort4DMAC0180C200000CRemoteBread-writecurrentEDD Series card Port 4 L2CP Mode 0180C200000C 0: Forward 1: Peer
1.3.6.1.4.1.4756.20.442.20.1.957ColumneddL2CPPort4DMAC0180C200000DRemoteBread-writecurrentEDD Series card Port 4 L2CP Mode 0180C200000D 0: Forward 1: Peer
1.3.6.1.4.1.4756.20.442.20.1.958ColumneddL2CPPort4DMAC0180C200000ERemoteBread-writecurrentEDD Series card Port 4 L2CP Mode 0180C200000E 0: Forward 1: Peer
1.3.6.1.4.1.4756.20.442.20.1.959ColumneddL2CPPort4DMAC0180C200000FRemoteBread-writecurrentEDD Series card Port 4 L2CP Mode 0180C200000F 0: Forward 1: Peer
1.3.6.1.4.1.4756.20.442.20.1.960ColumneddL2CPPort4DMAC0180C2000010RemoteBread-writecurrentEDD Series card Port 4 L2CP Mode 0180C2000010 0: Forward 1: Peer
1.3.6.1.4.1.4756.20.442.20.1.961ColumneddL2CPPort4DMAC0180C2000020RemoteBread-writecurrentEDD Series card Port 4 L2CP Mode 0180C2000020 0: Forward 1: Peer
1.3.6.1.4.1.4756.20.442.20.1.962ColumneddL2CPPort4DMAC0180C2000021RemoteBread-writecurrentEDD Series card Port 4 L2CP Mode 0180C2000021 0: Forward 1: Peer
1.3.6.1.4.1.4756.20.442.20.1.963ColumneddL2CPPort4DMAC0180C2000022RemoteBread-writecurrentEDD Series card Port 4 L2CP Mode 0180C2000022 0: Forward 1: Peer
1.3.6.1.4.1.4756.20.442.20.1.964ColumneddL2CPPort4DMAC0180C2000023RemoteBread-writecurrentEDD Series card Port 4 L2CP Mode 0180C2000023 0: Forward 1: Peer
1.3.6.1.4.1.4756.20.442.20.1.965ColumneddL2CPPort4DMAC0180C2000024RemoteBread-writecurrentEDD Series card Port 4 L2CP Mode 0180C2000024 0: Forward 1: Peer
1.3.6.1.4.1.4756.20.442.20.1.966ColumneddL2CPPort4DMAC0180C2000025RemoteBread-writecurrentEDD Series card Port 4 L2CP Mode 0180C2000025 0: Forward 1: Peer
1.3.6.1.4.1.4756.20.442.20.1.967ColumneddL2CPPort4DMAC0180C2000026RemoteBread-writecurrentEDD Series card Port 4 L2CP Mode 0180C2000026 0: Forward 1: Peer
1.3.6.1.4.1.4756.20.442.20.1.968ColumneddL2CPPort4DMAC0180C2000027RemoteBread-writecurrentEDD Series card Port 4 L2CP Mode 0180C2000027 0: Forward 1: Peer
1.3.6.1.4.1.4756.20.442.20.1.969ColumneddL2CPPort4DMAC0180C2000028RemoteBread-writecurrentEDD Series card Port 4 L2CP Mode 0180C2000028 0: Forward 1: Peer
1.3.6.1.4.1.4756.20.442.20.1.970ColumneddL2CPPort4DMAC0180C2000029RemoteBread-writecurrentEDD Series card Port 4 L2CP Mode 0180C2000029 0: Forward 1: Peer
1.3.6.1.4.1.4756.20.442.20.1.971ColumneddL2CPPort4DMAC0180C200002ARemoteBread-writecurrentEDD Series card Port 4 L2CP Mode 0180C200002A 0: Forward 1: Peer
1.3.6.1.4.1.4756.20.442.20.1.972ColumneddL2CPPort4DMAC0180C200002BRemoteBread-writecurrentEDD Series card Port 4 L2CP Mode 0180C200002B 0: Forward 1: Peer
1.3.6.1.4.1.4756.20.442.20.1.973ColumneddL2CPPort4DMAC0180C200002CRemoteBread-writecurrentEDD Series card Port 4 L2CP Mode 0180C200002C 0: Forward 1: Peer
1.3.6.1.4.1.4756.20.442.20.1.974ColumneddL2CPPort4DMAC0180C200002DRemoteBread-writecurrentEDD Series card Port 4 L2CP Mode 0180C200002D 0: Forward 1: Peer
1.3.6.1.4.1.4756.20.442.20.1.975ColumneddL2CPPort4DMAC0180C200002ERemoteBread-writecurrentEDD Series card Port 4 L2CP Mode 0180C200002E 0: Forward 1: Peer
1.3.6.1.4.1.4756.20.442.20.1.976ColumneddL2CPPort4DMAC0180C200002FRemoteBread-writecurrentEDD Series card Port 4 L2CP Mode 0180C200002F 0: Forward 1: Peer
1.3.6.1.4.1.4756.20.442.20.1.977ColumneddPort1MEPInstanceRemoteBread-writecurrentEDD Series card Port 1 MEP Instance 'MEP ID' must be an integer value between 0 and 8191.
1.3.6.1.4.1.4756.20.442.20.1.978ColumneddPort1MEPLogicRemoteBread-writecurrentEDD Series card Port 1 MEP Logic 0: And 1: OR
1.3.6.1.4.1.4756.20.442.20.1.979ColumneddPort2MEPInstanceRemoteBread-writecurrentEDD Series card Port 2 MEP Instance 'MEP ID' must be an integer value between 0 and 8191.
1.3.6.1.4.1.4756.20.442.20.1.980ColumneddPort2MEPLogicRemoteBread-writecurrentEDD Series card Port 2 MEP Logic 0: And 1: OR
1.3.6.1.4.1.4756.20.442.20.1.981ColumneddPort3MEPInstanceRemoteBread-writecurrentEDD Series card Port 3 MEP Instance 'MEP ID' must be an integer value between 0 and 8191.
1.3.6.1.4.1.4756.20.442.20.1.982ColumneddPort3MEPLogicRemoteBread-writecurrentEDD Series card Port 3 MEP Logic 0: And 1: OR
1.3.6.1.4.1.4756.20.442.20.1.983ColumneddPort4MEPInstanceRemoteBread-writecurrentEDD Series card Port 4 MEP Instance 'MEP ID' must be an integer value between 0 and 8191.
1.3.6.1.4.1.4756.20.442.20.1.984ColumneddPort4MEPLogicRemoteBread-writecurrentEDD Series card Port 4 MEP Logic 0: And 1: OR
1.3.6.1.4.1.4756.20.450Nodef100AS1LocalCards
1.3.6.1.4.1.4756.20.450.40Tablef100AS1LocalTablenot-accessiblecurrentA list of local 100AS-1 card entries.
1.3.6.1.4.1.4756.20.450.40.1Rowf100AS1LocalEntrynot-accessiblecurrentAn entry containing management information applicable to a particular local f100AS-1 card.
1.3.6.1.4.1.4756.20.450.40.1.1Columnf100AS1ChassisIndexLocalread-onlycurrentA unique value for each chassis ID. For CH20, it is the chassis ID. For CH08, it is always 0.
1.3.6.1.4.1.4756.20.450.40.1.2Columnf100AS1SlotIndexLocalread-onlycurrentA unique value for each local card. It is the slot location number.
1.3.6.1.4.1.4756.20.450.40.1.3Columnf100AS1CardHWVerLocalread-onlycurrentLocal device card hardware version x.xxx
1.3.6.1.4.1.4756.20.450.40.1.4Columnf100AS1CardFWVerLocalread-onlycurrentLocal device card firmware version x.xxx
1.3.6.1.4.1.4756.20.450.40.1.5Columnf100AS1CardCPLDVerLocalread-onlycurrentLocal device card CPLD version x.xxx
1.3.6.1.4.1.4756.20.450.40.1.6Columnf100AS1CardFPGAVerLocalread-onlycurrentLocal device card FPGA version x.xxx
1.3.6.1.4.1.4756.20.450.40.1.7Columnf100AS1ModelLocalread-onlycurrentLocal 100AS-1 Serial Type
1.3.6.1.4.1.4756.20.450.40.1.8Columnf100AS1FiberLinkLocalread-onlycurrentLocal device card fiber port link status: 0:Down 1:Up
1.3.6.1.4.1.4756.20.450.40.1.9Columnf100AS1FiberOAMLoopedLocalread-onlycurrentLocal device card fiber port OAM looped: 0:Off 1:on
1.3.6.1.4.1.4756.20.450.40.1.10Columnf100AS1FiberLBTestLocalread-writecurrentForce remote device card to do fiber port LoopBack testing: 0:Off 1:Action
1.3.6.1.4.1.4756.20.450.40.1.11Columnf100AS1FiberOAMRLBStatusLocalread-onlycurrentRemote device card fiber port LoopBack testing status: 0:Off 1:Ok 2:Fail
1.3.6.1.4.1.4756.20.450.40.1.12Columnf100AS1FiberRemoPwrAbLocalread-onlycurrentLocal device card fiber port 1 Remote Power status: 0:Abnormal 1:OK 2:None
1.3.6.1.4.1.4756.20.450.40.1.13Columnf100AS1FiberFEFLocalread-onlycurrentLocal device card fiber port FEF status: 0:Off 1:Detected
1.3.6.1.4.1.4756.20.450.40.1.14Columnf100AS1FiberIngressRateLocalread-writecurrentLocal device card fiber Ingress Rate Limit: 0 = Unlimit input format: 64k(K),99m(M),99 If doesn't input the unit, the default was Mega. Limite Rate : 64K ~ 99M
1.3.6.1.4.1.4756.20.450.40.1.15Columnf100AS1FiberEgressRateLocalread-writecurrentLocal device card fiber Egress Rate Limit: 0 = Unlimit input format: 64k(K),99m(M),99 If doesn't input the unit, the default was Mega. Limite Rate : 64K ~ 99M
1.3.6.1.4.1.4756.20.450.40.1.16Columnf100AS1UtpLinkLocalread-onlycurrentLocal device card UTP port link status: 0:Down 1:Up
1.3.6.1.4.1.4756.20.450.40.1.17Columnf100AS1UtpNegoLocalread-writecurrentLocal device card UTP port negotiation status: 0:Manual 1:Auto
1.3.6.1.4.1.4756.20.450.40.1.18Columnf100AS1UtpSpeedLocalread-writecurrentLocal device card UTP port speed setting: 0:10 Base-T 1:100 Base-TX
1.3.6.1.4.1.4756.20.450.40.1.19Columnf100AS1UtpDuplexLocalread-writecurrentLocal device card UTP port duplex setting: 0:Half duplex mode 1:Full duplex mode
1.3.6.1.4.1.4756.20.450.40.1.20Columnf100AS1UtpSpeedStatusLocalread-onlycurrentLocal device card UTP port speed status: 0:10 Base-T 1:100 Base-TX
1.3.6.1.4.1.4756.20.450.40.1.21Columnf100AS1UtpDuplexStatusLocalread-onlycurrentLocal device card UTP port duplex status: 0:Half duplex mode 1:Full duplex mode
1.3.6.1.4.1.4756.20.450.40.1.22Columnf100AS1UtpIngressRateLocalread-writecurrentLocal device card utp Ingress Rate Limit: 0 = Unlimit input format: 64k(K),99m(M),99 If doesn't input the unit, the default was Mega. Limite Rate : 64K ~ 99M
1.3.6.1.4.1.4756.20.450.40.1.23Columnf100AS1UtpEgressRateLocalread-writecurrentLocal device card utp Egress Rate Limit: 0 = Unlimit input format: 64k(K),99m(M),99 If doesn't input the unit, the default was Mega. Limite Rate : 64K ~ 99M
1.3.6.1.4.1.4756.20.450.40.1.24Columnf100AS1DeviceActiveLocalread-writecurrentLocal device card active mode: (It is read-only in remote device.) 0:Disable 1:Enable
1.3.6.1.4.1.4756.20.450.40.1.25Columnf100AS1DeviceResetLocalread-writecurrentForce local device card to reset mode: 0:Off 1:Action
1.3.6.1.4.1.4756.20.450.40.1.26Columnf100AS1FiberActiveLocalread-writecurrentLocal device fiber port active mode: 0:Disable 1:Enable
1.3.6.1.4.1.4756.20.450.40.1.27Columnf100AS1UtpActiveLocalread-writecurrentLocal device UTP port active mode: 0:Disable 1:Enable
1.3.6.1.4.1.4756.20.450.40.1.28Columnf100AS1OamChModeLocalread-writecurrentLocal device OAM Channel mode: 0:Disable 1:passive 2:Active
1.3.6.1.4.1.4756.20.450.40.1.29Columnf100AS1OamMaxPDUsLocalread-writecurrentLocal device OAM max OAMPDU size: 60-1518 Octets
1.3.6.1.4.1.4756.20.450.40.1.30Columnf100AS1FiberAlsLocalread-writecurrentLocal device card port Auto Laser Shutdown mode: 0:Disable 1:Enable
1.3.6.1.4.1.4756.20.450.40.1.31Columnf100AS1PauseFrameLocalread-writecurrentLocal device card pause frame mode: 0:Disable 1:Enable
1.3.6.1.4.1.4756.20.450.40.1.32Columnf100AS1SendFHRtoALocalread-writecurrentLocal device card port send Fiber Hardware Reset to remote: 0:No action 1:Action
1.3.6.1.4.1.4756.20.450.40.1.33Columnf100AS1FiberLLFDepPortLocalread-writecurrentLocal device card port Link Loss Forwarding depends on port 3 Ethernet Rx link: 0:don't care 1:selected
1.3.6.1.4.1.4756.20.450.40.1.34Columnf100AS1UtpLLFDepPortLocalread-writecurrentLocal device card port Link Loss Forwarding depends on port Fiber Rx link: 0:don't care 1:selected
1.3.6.1.4.1.4756.20.450.40.1.35Columnf100AS1AdvanceFunsLocalread-writecurrentLocal device card Switch functions mode: 0:Normal 5:Static 802.1Q VLAN 6:Spanning Tree Protocol 7:802.1Q VLAN Trunk 9:Q in Q VLAN 11:Spanning Tree Protocol and…
1.3.6.1.4.1.4756.20.450.40.1.36Columnf100AS1FiberInfoROM1Localread-onlycurrentLocal device card port INFORemoteOM information 1 valid: 0:Invalid 1:Valid
1.3.6.1.4.1.4756.20.450.40.1.37Columnf100AS1FiberInfoROM2Localread-onlycurrentLocal device card port INFORemoteOM information 2 valid: 0:Invalid 1:Valid(replacing D/D function
1.3.6.1.4.1.4756.20.450.40.1.38Columnf100AS1FiberInfoSN1Localread-onlycurrentLocal device card port 1 NFORemoteOM S/N 1
1.3.6.1.4.1.4756.20.450.40.1.39Columnf100AS1FiberInfoSN2Localread-onlycurrentLocal device card port 1 INFORemoteOM S/N 2
1.3.6.1.4.1.4756.20.450.40.1.40Columnf100AS1FiberDDLocalread-onlycurrentLocal device card fiber port Digital Diagnostic function: 0:No 1:Yes
1.3.6.1.4.1.4756.20.450.40.1.41Columnf100AS1FiberDDVendorLocalread-onlycurrentLocal device card fiber port D/D information: Vendor name
1.3.6.1.4.1.4756.20.450.40.1.42Columnf100AS1FiberDDPartNoLocalread-onlycurrentLocal device card fiber port D/D information: Vendor part number
1.3.6.1.4.1.4756.20.450.40.1.43Columnf100AS1FiberDDFiberTypeLocalread-onlycurrentLocal device card fiber port D/D information: Fiber Type
1.3.6.1.4.1.4756.20.450.40.1.44Columnf100AS1FiberDDWaveLenLocalread-onlycurrentLocal device card fiber port D/D information: Wave length
1.3.6.1.4.1.4756.20.450.40.1.45Columnf100AS1FiberDDWaveLen2Localread-onlycurrentLocal device card fiber port D/D information: Wave length 2
1.3.6.1.4.1.4756.20.450.40.1.46Columnf100AS1FiberDDLinkLenLocalread-onlycurrentLocal device card fiber port D/D information: Link length
1.3.6.1.4.1.4756.20.450.40.1.47Columnf100AS1FiberDDLenUnitLocalread-onlycurrentLocal device card fiber port D/D information: Length Unit
1.3.6.1.4.1.4756.20.450.40.1.48Columnf100AS1FiberDDStatusLocalread-onlycurrentLocal device card fiber port D/D information: Status Support
1.3.6.1.4.1.4756.20.450.40.1.49Columnf100AS1FiberDDRxSensLocalread-onlycurrentLocal device card fiber port D/D information: Rx Sensitivity
1.3.6.1.4.1.4756.20.450.40.1.50Columnf100AS1FiberDDTxPWRLocalread-onlycurrentLocal device card fiber port D/D information: Tx power
1.3.6.1.4.1.4756.20.450.40.1.51Columnf100AS1FiberDDRxPWRLocalread-onlycurrentLocal device card fiber port D/D information: Rx power
1.3.6.1.4.1.4756.20.450.40.1.52Columnf100AS1FiberDDTempLocalread-onlycurrentLocal device card fiber port D/D information: Temperature in degree C
1.3.6.1.4.1.4756.20.450.40.1.53Columnf100AS1FiberDDPWRMarginLocalread-onlycurrentLocal device card fiber port D/D information: Power margin
1.3.6.1.4.1.4756.20.450.40.1.54Columnf100AS1FiberDDPWRLossLocalread-onlycurrentLocal device card fiber port D/D information: Power loss
1.3.6.1.4.1.4756.20.450.40.1.55Columnf100AS1ClrRMONCntsLocalread-writecurrentClear local device card RMON IN/OUT counters: 0:No action 1:Action
1.3.6.1.4.1.4756.20.450.40.1.56Columnf100AS1FiberRMONInLocalread-onlycurrentLocal device card port RMON IN counter.
1.3.6.1.4.1.4756.20.450.40.1.57Columnf100AS1FiberRMONOutLocalread-onlycurrentLocal device card port RMON OUT counter.
1.3.6.1.4.1.4756.20.450.40.1.58Columnf100AS1UtpRMONInLocalread-onlycurrentLocal device card port RMON IN counter.
1.3.6.1.4.1.4756.20.450.40.1.59Columnf100AS1UtpRMONOutLocalread-onlycurrentLocal device card port RMON OUT counter.
1.3.6.1.4.1.4756.20.450.40.1.60Columnf100AS1ClrOAMCntsLocalread-writecurrentClear local device card OAM counters: 0:No action 1:Action
1.3.6.1.4.1.4756.20.450.40.1.61Columnf100AS1IpModeLocalread-writecurrentOn Rack Ip Mode: 0:Enable 1:Disable
1.3.6.1.4.1.4756.20.450.40.1.62Columnf100AS1OamChTxLocalread-onlycurrentLocal device OAM Channel TX OAMPDU frame count
1.3.6.1.4.1.4756.20.450.40.1.63Columnf100AS1OamChRxLocalread-onlycurrentLocal device OAM Channel RX OAMPDU frame count
1.3.6.1.4.1.4756.20.450.40.1.64Columnf100AS1OamInfoChTxLocalread-onlycurrentLocal device OAM Channel TX Information OAMPDU frame count
1.3.6.1.4.1.4756.20.450.40.1.65Columnf100AS1OamInfoChRxLocalread-onlycurrentLocal device OAM Channel RX Information OAMPDU frame count
1.3.6.1.4.1.4756.20.450.40.1.66Columnf100AS1OamEventChTxLocalread-onlycurrentLocal device OAM Channel TX Event OAMPDU frame count
1.3.6.1.4.1.4756.20.450.40.1.67Columnf100AS1OamUniEvtChRxLocalread-onlycurrentLocal device OAM Channel RX Unique Event OAMPDU frame count
1.3.6.1.4.1.4756.20.450.40.1.68Columnf100AS1OamDupEvtChRxLocalread-onlycurrentLocal device OAM Channel RX Duplicate Event OAMPDU frame count
1.3.6.1.4.1.4756.20.450.40.1.69Columnf100AS1OamLbChTxLocalread-onlycurrentLocal device OAM Channel TX Loopback Control OAMPDU frame count
1.3.6.1.4.1.4756.20.450.40.1.70Columnf100AS1OamLbChRxLocalread-onlycurrentLocal device OAM Channel RX Loopback Control OAMPDU frame count
1.3.6.1.4.1.4756.20.450.40.1.71Columnf100AS1OamVarReqChTxLocalread-onlycurrentLocal device OAM Channel TX Variable Request OAMPDU frame count
1.3.6.1.4.1.4756.20.450.40.1.72Columnf100AS1OamVarReqChRxLocalread-onlycurrentLocal device OAM Channel RX Variable Request OAMPDU frame count
1.3.6.1.4.1.4756.20.450.40.1.73Columnf100AS1OamVarRspChTxLocalread-onlycurrentLocal device OAM Channel TX Variable Response OAMPDU frame count
1.3.6.1.4.1.4756.20.450.40.1.74Columnf100AS1OamVarRspChRxLocalread-onlycurrentLocal device OAM Channel RX Variable Response OAMPDU frame count
1.3.6.1.4.1.4756.20.450.40.1.75Columnf100AS1OamOuiChTxLocalread-onlycurrentLocal device OAM Channel TX OUI OAMPDU frame count
1.3.6.1.4.1.4756.20.450.40.1.76Columnf100AS1OamOuiChRxLocalread-onlycurrentLocal device OAM Channel RX OUI OAMPDU frame count
1.3.6.1.4.1.4756.20.450.40.1.77Columnf100AS1OamUnknowChRxLocalread-onlycurrentLocal device OAM Channel RX Unsupported OAMPDU frame count
1.3.6.1.4.1.4756.20.450.40.1.78Columnf100AS1FiberSpeedLocalread-onlycurrentLocal device Fiber speed : 1:100
1.3.6.1.4.1.4756.20.450.40.1.79Columnf100AS1MacLearningLocalread-writecurrentLocal device Mac learning : 0:Disable 1:Enable
1.3.6.1.4.1.4756.20.450.40.1.80Columnf100AS1Port1VIDLocalread-writecurrentLocal device Port 1 VID :
1.3.6.1.4.1.4756.20.450.40.1.81Columnf100AS1Port2VIDLocalread-writecurrentLocal device Port 2 VID :
1.3.6.1.4.1.4756.20.450.40.1.82Columnf100AS1Port1QinQLocalread-writecurrentLocal device Port 1 Q in Q Support : 1:Disable 2:Enable
1.3.6.1.4.1.4756.20.450.40.1.83Columnf100AS1Port2QinQLocalread-writecurrentLocal device Port 2 Q in Q Support : 1:Disable 2:Enable
1.3.6.1.4.1.4756.20.450.40.1.84Columnf100AS1VID1Localread-writecurrentLocal device VID 1:
1.3.6.1.4.1.4756.20.450.40.1.85Columnf100AS1VID2Localread-writecurrentLocal device VID 2:
1.3.6.1.4.1.4756.20.450.40.1.86Columnf100AS1VID3Localread-writecurrentLocal device VID 3:
1.3.6.1.4.1.4756.20.450.40.1.87Columnf100AS1VID4Localread-writecurrentLocal device VID 4:
1.3.6.1.4.1.4756.20.450.40.1.88Columnf100AS1VID5Localread-writecurrentLocal device VID 5:
1.3.6.1.4.1.4756.20.450.40.1.89Columnf100AS1VID6Localread-writecurrentLocal device VID 6:
1.3.6.1.4.1.4756.20.450.40.1.90Columnf100AS1VID7Localread-writecurrentLocal device VID 7:
1.3.6.1.4.1.4756.20.450.40.1.91Columnf100AS1VID8Localread-writecurrentLocal device VID 8:
1.3.6.1.4.1.4756.20.450.40.1.92Columnf100AS1VID9Localread-writecurrentLocal device VID 9:
1.3.6.1.4.1.4756.20.450.40.1.93Columnf100AS1VID10Localread-writecurrentLocal device VID 10:
1.3.6.1.4.1.4756.20.450.40.1.94Columnf100AS1VID11Localread-writecurrentLocal device VID 11:
1.3.6.1.4.1.4756.20.450.40.1.95Columnf100AS1VID12Localread-writecurrentLocal device VID 12:
1.3.6.1.4.1.4756.20.450.40.1.96Columnf100AS1VID13Localread-writecurrentLocal device VID 13:
1.3.6.1.4.1.4756.20.450.40.1.97Columnf100AS1VID14Localread-writecurrentLocal device VID 14:
1.3.6.1.4.1.4756.20.450.40.1.98Columnf100AS1VID15Localread-writecurrentLocal device VID 15:
1.3.6.1.4.1.4756.20.450.40.1.99Columnf100AS1VID16Localread-writecurrentLocal device VID 16:
1.3.6.1.4.1.4756.20.450.40.1.100Columnf100AS1Port1Member1Localread-writecurrentLocal device card port 1 member: 0:Unmodify 1:Untagged 2:Tagged 3:Nonmember
1.3.6.1.4.1.4756.20.450.40.1.101Columnf100AS1Port1Member2Localread-writecurrentLocal device card port 1 member 2: 0:Unmodify 1:Untagged 2:Tagged 3:Nonmember
1.3.6.1.4.1.4756.20.450.40.1.102Columnf100AS1Port1Member3Localread-writecurrentLocal device card port 1 member 3: 0:Unmodify 1:Untagged 2:Tagged 3:Nonmember
1.3.6.1.4.1.4756.20.450.40.1.103Columnf100AS1Port1Member4Localread-writecurrentLocal device card port 1 member 4: 0:Unmodify 1:Untagged 2:Tagged 3:Nonmember
1.3.6.1.4.1.4756.20.450.40.1.104Columnf100AS1Port1Member5Localread-writecurrentLocal device card port 1 member 5: 0:Unmodify 1:Untagged 2:Tagged 3:Nonmember
1.3.6.1.4.1.4756.20.450.40.1.105Columnf100AS1Port1Member6Localread-writecurrentLocal device card port 1 member 6: 0:Unmodify 1:Untagged 2:Tagged 3:Nonmember
1.3.6.1.4.1.4756.20.450.40.1.106Columnf100AS1Port1Member7Localread-writecurrentLocal device card port 1 member 7: 0:Unmodify 1:Untagged 2:Tagged 3:Nonmember
1.3.6.1.4.1.4756.20.450.40.1.107Columnf100AS1Port1Member8Localread-writecurrentLocal device card port 1 member 8: 0:Unmodify 1:Untagged 2:Tagged 3:Nonmember
1.3.6.1.4.1.4756.20.450.40.1.108Columnf100AS1Port1Member9Localread-writecurrentLocal device card port 1 member 9: 0:Unmodify 1:Untagged 2:Tagged 3:Nonmember
1.3.6.1.4.1.4756.20.450.40.1.109Columnf100AS1Port1Member10Localread-writecurrentLocal device card port 1 member 10: 0:Unmodify 1:Untagged 2:Tagged 3:Nonmember
1.3.6.1.4.1.4756.20.450.40.1.110Columnf100AS1Port1Member11Localread-writecurrentLocal device card port 1 member 11: 0:Unmodify 1:Untagged 2:Tagged 3:Nonmember
1.3.6.1.4.1.4756.20.450.40.1.111Columnf100AS1Port1Member12Localread-writecurrentLocal device card port 1 member 12: 0:Unmodify 1:Untagged 2:Tagged 3:Nonmember
1.3.6.1.4.1.4756.20.450.40.1.112Columnf100AS1Port1Member13Localread-writecurrentLocal device card port 1 member 13: 0:Unmodify 1:Untagged 2:Tagged 3:Nonmember
1.3.6.1.4.1.4756.20.450.40.1.113Columnf100AS1Port1Member14Localread-writecurrentLocal device card port 1 member 14: 0:Unmodify 1:Untagged 2:Tagged 3:Nonmember
1.3.6.1.4.1.4756.20.450.40.1.114Columnf100AS1Port1Member15Localread-writecurrentLocal device card port 1 member 15: 0:Unmodify 1:Untagged 2:Tagged 3:Nonmember
1.3.6.1.4.1.4756.20.450.40.1.115Columnf100AS1Port1Member16Localread-writecurrentLocal device card port 1 member 16: 0:Unmodify 1:Untagged 2:Tagged 3:Nonmember
1.3.6.1.4.1.4756.20.450.40.1.116Columnf100AS1Port2Member1Localread-writecurrentLocal device card port 2 member: 0:Unmodify 1:Untagged 2:Tagged 3:Nonmember
1.3.6.1.4.1.4756.20.450.40.1.117Columnf100AS1Port2Member2Localread-writecurrentLocal device card port 2 member 2: 0:Unmodify 1:Untagged 2:Tagged 3:Nonmember
1.3.6.1.4.1.4756.20.450.40.1.118Columnf100AS1Port2Member3Localread-writecurrentLocal device card port 2 member 3: 0:Unmodify 1:Untagged 2:Tagged 3:Nonmember
1.3.6.1.4.1.4756.20.450.40.1.119Columnf100AS1Port2Member4Localread-writecurrentLocal device card port 2 member 4: 0:Unmodify 1:Untagged 2:Tagged 3:Nonmember
1.3.6.1.4.1.4756.20.450.40.1.120Columnf100AS1Port2Member5Localread-writecurrentLocal device card port 2 member 5: 0:Unmodify 1:Untagged 2:Tagged 3:Nonmember
1.3.6.1.4.1.4756.20.450.40.1.121Columnf100AS1Port2Member6Localread-writecurrentLocal device card port 2 member 6: 0:Unmodify 1:Untagged 2:Tagged 3:Nonmember
1.3.6.1.4.1.4756.20.450.40.1.122Columnf100AS1Port2Member7Localread-writecurrentLocal device card port 2 member 7: 0:Unmodify 1:Untagged 2:Tagged 3:Nonmember
1.3.6.1.4.1.4756.20.450.40.1.123Columnf100AS1Port2Member8Localread-writecurrentLocal device card port 2 member 8: 0:Unmodify 1:Untagged 2:Tagged 3:Nonmember
1.3.6.1.4.1.4756.20.450.40.1.124Columnf100AS1Port2Member9Localread-writecurrentLocal device card port 2 member 9: 0:Unmodify 1:Untagged 2:Tagged 3:Nonmember
1.3.6.1.4.1.4756.20.450.40.1.125Columnf100AS1Port2Member10Localread-writecurrentLocal device card port 2 member 10: 0:Unmodify 1:Untagged 2:Tagged 3:Nonmember
1.3.6.1.4.1.4756.20.450.40.1.126Columnf100AS1Port2Member11Localread-writecurrentLocal device card port 2 member 11: 0:Unmodify 1:Untagged 2:Tagged 3:Nonmember
1.3.6.1.4.1.4756.20.450.40.1.127Columnf100AS1Port2Member12Localread-writecurrentLocal device card port 2 member 12: 0:Unmodify 1:Untagged 2:Tagged 3:Nonmember
1.3.6.1.4.1.4756.20.450.40.1.128Columnf100AS1Port2Member13Localread-writecurrentLocal device card port 2 member 13: 0:Unmodify 1:Untagged 2:Tagged 3:Nonmember
1.3.6.1.4.1.4756.20.450.40.1.129Columnf100AS1Port2Member14Localread-writecurrentLocal device card port 2 member 14: 0:Unmodify 1:Untagged 2:Tagged 3:Nonmember
1.3.6.1.4.1.4756.20.450.40.1.130Columnf100AS1Port2Member15Localread-writecurrentLocal device card port 2 member 15: 0:Unmodify 1:Untagged 2:Tagged 3:Nonmember
1.3.6.1.4.1.4756.20.450.40.1.131Columnf100AS1Port2Member16Localread-writecurrentLocal device card port 2 member 16: 0:Unmodify 1:Untagged 2:Tagged 3:Nonmember
1.3.6.1.4.1.4756.20.450.40.1.132Columnf100AS1IpAddressLocalread-writecurrentLocal device IP address
1.3.6.1.4.1.4756.20.450.40.1.133Columnf100AS1NetMaskLocalread-writecurrentLocal device Netmask
1.3.6.1.4.1.4756.20.450.40.1.134Columnf100AS1GateWayLocalread-writecurrentLocal device Gateway
1.3.6.1.4.1.4756.20.450.40.1.135Columnf100AS1SetDefaultLocalread-writecurrentLocal device set to default
1.3.6.1.4.1.4756.20.450.40.1.136Columnf100AS1ManagementVIDLocalread-writecurrentLocal device Management VID :
1.3.6.1.4.1.4756.20.450.40.1.137Columnf100AS1TagTypeLocalread-writecurrentLocal device Tag Type (HEX) :
1.3.6.1.4.1.4756.20.450.40.1.138Columnf100AS1FxLinkAlarmLocalread-writecurrentLocal device fiber link alarm 0:Disable 1:Enable
1.3.6.1.4.1.4756.20.450.40.1.139Columnf100AS1UtpLinkAlarmLocalread-writecurrentLocal device utp link alarm 0:Disable 1:Enable
1.3.6.1.4.1.4756.20.450.40.1.140Columnf100AS1PingStatusLocalread-onlycurrentLocal device icmp ping status Show Ping Status 0: Normal 1: Not Ready 2: 5 packets transmitted, 5 received, 0 packet loss. (Ping OK) 3: 5 packets transmitted, …
1.3.6.1.4.1.4756.20.450.40.1.141Columnf100AS1PingIpAddressLocalread-writecurrentLocal device ping IP address
1.3.6.1.4.1.4756.20.450.40.1.142Columnf100AS1PingStartLocalread-writecurrentLocal device ping start 0:Off 1:Action
1.3.6.1.4.1.4756.20.450.40.1.143Columnf100AS1RemoteTLPTLocalread-writecurrentLocal device Remote TLPT mode : 0:Disalbe 1:Remote
1.3.6.1.4.1.4756.20.450.40.1.144Columnf100AS1FxLBTLocalread-writecurrentFRM220-100AS-1A Fiber LoopBack Test: 0: Disalbe 1: Enable 2: Not Support
1.3.6.1.4.1.4756.20.450.40.1.145Columnf100AS1UtpLBTLocalread-writecurrentFRM220-100AS-1A UTP LoopBack Test: 0: Disalbe 1: Enable 2: Not Support
1.3.6.1.4.1.4756.20.451Nodef100AS1RemoteACards
1.3.6.1.4.1.4756.20.451.40Tablef100AS1RemoteATablenot-accessiblecurrentA list of RemoteA 100AS-1 card entries.
1.3.6.1.4.1.4756.20.451.40.1Rowf100AS1RemoteAEntrynot-accessiblecurrentAn entry containing management information applicable to a particular RemoteA f100AS-1 card.
1.3.6.1.4.1.4756.20.451.40.1.1Columnf100AS1ChassisIndexRemoteAread-onlycurrentA unique value for each chassis ID. For CH20, it is the chassis ID. For CH08, it is always 0.
1.3.6.1.4.1.4756.20.451.40.1.2Columnf100AS1SlotIndexRemoteAread-onlycurrentA unique value for each RemoteA card. It is the slot location number.
1.3.6.1.4.1.4756.20.451.40.1.3Columnf100AS1CardHWVerRemoteAread-onlycurrentRemoteA device card hardware version x.xxx
1.3.6.1.4.1.4756.20.451.40.1.4Columnf100AS1CardFWVerRemoteAread-onlycurrentRemoteA device card firmware version x.xxx
1.3.6.1.4.1.4756.20.451.40.1.5Columnf100AS1CardCPLDVerRemoteAread-onlycurrentRemoteA device card CPLD version x.xxx
1.3.6.1.4.1.4756.20.451.40.1.6Columnf100AS1CardFPGAVerRemoteAread-onlycurrentRemoteA device card FPGA version x.xxx
1.3.6.1.4.1.4756.20.451.40.1.7Columnf100AS1ModelRemoteAread-onlycurrentRemoteA 100AS-1 Serial Type
1.3.6.1.4.1.4756.20.451.40.1.8Columnf100AS1FiberLinkRemoteAread-onlycurrentRemoteA device card fiber port link status: 0:Down 1:Up
1.3.6.1.4.1.4756.20.451.40.1.9Columnf100AS1FiberOAMLoopedRemoteAread-onlycurrentRemoteA device card fiber port OAM looped: 0:Off 1:on
1.3.6.1.4.1.4756.20.451.40.1.10Columnf100AS1FiberLBTestRemoteAread-writecurrentForce remote device card to do fiber port LoopBack testing: 0:Off 1:Action
1.3.6.1.4.1.4756.20.451.40.1.11Columnf100AS1FiberOAMRLBStatusRemoteAread-onlycurrentRemoteA device card fiber port LoopBack testing status: 0:Off 1:Ok 2:Fail
1.3.6.1.4.1.4756.20.451.40.1.12Columnf100AS1FiberRemoPwrAbRemoteAread-onlycurrentRemoteA device card fiber port RemoteA Power status: 0:Abnormal 1:OK 2:None
1.3.6.1.4.1.4756.20.451.40.1.13Columnf100AS1FiberFEFRemoteAread-onlycurrentRemoteA device card fiber port FEF status: 0:Abnormal 1:OFF 2:Detected
1.3.6.1.4.1.4756.20.451.40.1.14Columnf100AS1FiberIngressRateRemoteAread-writecurrentRemoteA device card fiber Ingress Rate Limit: 0 = Unlimit input format: 64k(K),99m(M),99 If doesn't input the unit, the default was Mega. Limite Rate : 64K ~ 9…
1.3.6.1.4.1.4756.20.451.40.1.15Columnf100AS1FiberEgressRateRemoteAread-writecurrentRemoteA device card fiber Egress Rate Limit: 0 = Unlimit input format: 64k(K),99m(M),99 If doesn't input the unit, the default was Mega. Limite Rate : 64K ~ 99M
1.3.6.1.4.1.4756.20.451.40.1.16Columnf100AS1UtpLinkRemoteAread-onlycurrentRemoteA device card UTP port link status: 0:Down 1:Up
1.3.6.1.4.1.4756.20.451.40.1.17Columnf100AS1UtpNegoRemoteAread-writecurrentRemoteA device card UTP port negotiation status: 0:Manual 1:Auto
1.3.6.1.4.1.4756.20.451.40.1.18Columnf100AS1UtpSpeedRemoteAread-writecurrentRemoteA device card UTP port speed setting: 0:10 Base-T 1:100 Base-TX
1.3.6.1.4.1.4756.20.451.40.1.19Columnf100AS1UtpDuplexRemoteAread-writecurrentRemoteA device card UTP port duplex setting: 0:Half duplex mode 1:Full duplex mode
1.3.6.1.4.1.4756.20.451.40.1.20Columnf100AS1UtpSpeedStatusRemoteAread-onlycurrentRemoteA device card UTP port speed status: 0:10 Base-T 1:100 Base-TX
1.3.6.1.4.1.4756.20.451.40.1.21Columnf100AS1UtpDuplexStatusRemoteAread-onlycurrentRemoteA device card UTP port duplex status: 0:Half duplex mode 1:Full duplex mode
1.3.6.1.4.1.4756.20.451.40.1.22Columnf100AS1UtpIngressRateRemoteAread-writecurrentRemoteA device card utp Ingress Rate Limit: 0 = Unlimit input format: 64k(K),99m(M),99 If doesn't input the unit, the default was Mega. Limite Rate : 64K ~ 99M
1.3.6.1.4.1.4756.20.451.40.1.23Columnf100AS1UtpEgressRateRemoteAread-writecurrentRemoteA device card utp Egress Rate Limit: 0 = Unlimit input format: 64k(K),99m(M),99 If doesn't input the unit, the default was Mega. Limite Rate : 64K ~ 99M
1.3.6.1.4.1.4756.20.451.40.1.24Columnf100AS1DeviceResetRemoteAread-writecurrentForce RemoteA device card to reset mode: 0:Off 1:Action
1.3.6.1.4.1.4756.20.451.40.1.25Columnf100AS1UtpActiveRemoteAread-writecurrentRemoteA device UTP port active mode: 0:Disable 1:Enable
1.3.6.1.4.1.4756.20.451.40.1.26Columnf100AS1OamChModeRemoteAread-writecurrentRemoteA device OAM Channel mode: 0:Disable 1:passive 2:Active
1.3.6.1.4.1.4756.20.451.40.1.27Columnf100AS1OamMaxPDUsRemoteAread-writecurrentRemoteA device OAM max OAMPDU size: 60-1518 Octets
1.3.6.1.4.1.4756.20.451.40.1.28Columnf100AS1FiberAlsRemoteAread-writecurrentRemoteA device card port Auto Laser Shutdown mode: 0:Disable 1:Enable
1.3.6.1.4.1.4756.20.451.40.1.29Columnf100AS1PauseFrameRemoteAread-writecurrentRemoteA device card pause frame mode: 0:Disable 1:Enable
1.3.6.1.4.1.4756.20.451.40.1.30Columnf100AS1FHRModeRemoteAread-writecurrentRemoteA device card FHR Mode: 0:Disable 1:Enable
1.3.6.1.4.1.4756.20.451.40.1.31Columnf100AS1FiberLLFDepPortRemoteAread-writecurrentRemoteA device card port Link Loss Forwarding depends on port Ethernet Rx link: 0:don't care 1:selected
1.3.6.1.4.1.4756.20.451.40.1.32Columnf100AS1UtpLLFDepPortRemoteAread-writecurrentRemoteA device card port Link Loss Forwarding depends on port Fiber Rx link: 0:don't care 1:selected
1.3.6.1.4.1.4756.20.451.40.1.33Columnf100AS1AdvanceFunsRemoteAread-writecurrentRemoteA device card Switch functions mode: 0:Normal 5:Static 802.1Q VLAN 6:Spanning Tree Protocol 7:802.1Q VLAN Trunk 9:Q in Q VLAN 11:Spanning Tree Protocol &…
1.3.6.1.4.1.4756.20.451.40.1.34Columnf100AS1FiberInfoROM1RemoteAread-onlycurrentRemoteA device card port INFORemoteAOM information 1 valid: 0:Invalid 1:Valid
1.3.6.1.4.1.4756.20.451.40.1.35Columnf100AS1FiberInfoROM2RemoteAread-onlycurrentRemoteA device card port INFORemoteAOM information 2 valid: 0:Invalid 1:Valid(replacing D/D function
1.3.6.1.4.1.4756.20.451.40.1.36Columnf100AS1FiberInfoSN1RemoteAread-onlycurrentRemoteA device card port INFORemoteOM S/N 1
1.3.6.1.4.1.4756.20.451.40.1.37Columnf100AS1FiberInfoSN2RemoteAread-onlycurrentRemoteA device card port INFORemoteOM S/N 2
1.3.6.1.4.1.4756.20.451.40.1.38Columnf100AS1FiberDDRemoteAread-onlycurrentRemoteA device card fiber port Digital Diagnostic function: 0:No 1:Yes
1.3.6.1.4.1.4756.20.451.40.1.39Columnf100AS1FiberDDVendorRemoteAread-onlycurrentRemoteA device card fiber port D/D information: Vendor name
1.3.6.1.4.1.4756.20.451.40.1.40Columnf100AS1FiberDDPartNoRemoteAread-onlycurrentRemoteA device card fiber port D/D information: Vendor part number
1.3.6.1.4.1.4756.20.451.40.1.41Columnf100AS1FiberDDFiberTypeRemoteAread-onlycurrentRemoteA device card fiber port D/D information: Fiber Type
1.3.6.1.4.1.4756.20.451.40.1.42Columnf100AS1FiberDDWaveLenRemoteAread-onlycurrentRemoteA device card fiber port D/D information: Wave length
1.3.6.1.4.1.4756.20.451.40.1.43Columnf100AS1FiberDDWaveLen2RemoteAread-onlycurrentRemoteA device card fiber port D/D information: Wave length 2
1.3.6.1.4.1.4756.20.451.40.1.44Columnf100AS1FiberDDLinkLenRemoteAread-onlycurrentRemoteA device card fiber port D/D information: Link length
1.3.6.1.4.1.4756.20.451.40.1.45Columnf100AS1FiberDDLenUnitRemoteAread-onlycurrentRemoteA device card fiber port D/D information: Length Unit
1.3.6.1.4.1.4756.20.451.40.1.46Columnf100AS1FiberDDStatusRemoteAread-onlycurrentRemoteA device card fiber port D/D information: Status Support
1.3.6.1.4.1.4756.20.451.40.1.47Columnf100AS1FiberDDRxSensRemoteAread-onlycurrentRemoteA device card fiber port D/D information: Rx Sensitivity
1.3.6.1.4.1.4756.20.451.40.1.48Columnf100AS1FiberDDTxPWRRemoteAread-onlycurrentRemoteA device card fiber port D/D information: Tx power
1.3.6.1.4.1.4756.20.451.40.1.49Columnf100AS1FiberDDRxPWRRemoteAread-onlycurrentRemoteA device card fiber port D/D information: Rx power
1.3.6.1.4.1.4756.20.451.40.1.50Columnf100AS1FiberDDTempRemoteAread-onlycurrentRemoteA device card fiber port D/D information: Temperature in degree C
1.3.6.1.4.1.4756.20.451.40.1.51Columnf100AS1FiberDDPWRMarginRemoteAread-onlycurrentRemoteA device card fiber port D/D information: Power margin
1.3.6.1.4.1.4756.20.451.40.1.52Columnf100AS1FiberDDPWRLossRemoteAread-onlycurrentRemoteA device card fiber port D/D information: Power loss
1.3.6.1.4.1.4756.20.451.40.1.53Columnf100AS1ClrRMONCntsRemoteAread-writecurrentClear RemoteA device card RMON IN/OUT counters: 0:No action 1:Action
1.3.6.1.4.1.4756.20.451.40.1.54Columnf100AS1FiberRMONInRemoteAread-onlycurrentRemoteA device card port RMON IN counter.
1.3.6.1.4.1.4756.20.451.40.1.55Columnf100AS1FiberRMONOutRemoteAread-onlycurrentRemoteA device card port RMON OUT counter.
1.3.6.1.4.1.4756.20.451.40.1.56Columnf100AS1UtpRMONInRemoteAread-onlycurrentRemoteA device card port RMON IN counter.
1.3.6.1.4.1.4756.20.451.40.1.57Columnf100AS1UtpRMONOutRemoteAread-onlycurrentRemoteA device card port RMON OUT counter.
1.3.6.1.4.1.4756.20.451.40.1.58Columnf100AS1ClrOAMCntsRemoteAread-writecurrentClear RemoteA device card OAM counters: 0:No action 1:Action
1.3.6.1.4.1.4756.20.451.40.1.59Columnf100AS1IpModeRemoteAread-writecurrentOn Rack Ip Mode: 0:Enable 1:Disable
1.3.6.1.4.1.4756.20.451.40.1.60Columnf100AS1OamChTxRemoteAread-onlycurrentRemoteA device OAM Channel TX OAMPDU frame count
1.3.6.1.4.1.4756.20.451.40.1.61Columnf100AS1OamChRxRemoteAread-onlycurrentRemoteA device OAM Channel RX OAMPDU frame count
1.3.6.1.4.1.4756.20.451.40.1.62Columnf100AS1OamInfoChTxRemoteAread-onlycurrentRemoteA device OAM Channel TX Information OAMPDU frame count
1.3.6.1.4.1.4756.20.451.40.1.63Columnf100AS1OamInfoChRxRemoteAread-onlycurrentRemoteA device OAM Channel RX Information OAMPDU frame count
1.3.6.1.4.1.4756.20.451.40.1.64Columnf100AS1OamEventChTxRemoteAread-onlycurrentRemoteA device OAM Channel TX Event OAMPDU frame count
1.3.6.1.4.1.4756.20.451.40.1.65Columnf100AS1OamUniEvtChRxRemoteAread-onlycurrentRemoteA device OAM Channel RX Unique Event OAMPDU frame count
1.3.6.1.4.1.4756.20.451.40.1.66Columnf100AS1OamDupEvtChRxRemoteAread-onlycurrentRemoteA device OAM Channel RX Duplicate Event OAMPDU frame count
1.3.6.1.4.1.4756.20.451.40.1.67Columnf100AS1OamLbChTxRemoteAread-onlycurrentRemoteA device OAM Channel TX Loopback Control OAMPDU frame count
1.3.6.1.4.1.4756.20.451.40.1.68Columnf100AS1OamLbChRxRemoteAread-onlycurrentRemoteA device OAM Channel RX Loopback Control OAMPDU frame count
1.3.6.1.4.1.4756.20.451.40.1.69Columnf100AS1OamVarReqChTxRemoteAread-onlycurrentRemoteA device OAM Channel TX Variable Request OAMPDU frame count
1.3.6.1.4.1.4756.20.451.40.1.70Columnf100AS1OamVarReqChRxRemoteAread-onlycurrentRemoteA device OAM Channel RX Variable Request OAMPDU frame count
1.3.6.1.4.1.4756.20.451.40.1.71Columnf100AS1OamVarRspChTxRemoteAread-onlycurrentRemoteA device OAM Channel TX Variable Response OAMPDU frame count
1.3.6.1.4.1.4756.20.451.40.1.72Columnf100AS1OamVarRspChRxRemoteAread-onlycurrentRemoteA device OAM Channel RX Variable Response OAMPDU frame count
1.3.6.1.4.1.4756.20.451.40.1.73Columnf100AS1OamOuiChTxRemoteAread-onlycurrentRemoteA device OAM Channel TX OUI OAMPDU frame count
1.3.6.1.4.1.4756.20.451.40.1.74Columnf100AS1OamOuiChRxRemoteAread-onlycurrentRemoteA device OAM Channel RX OUI OAMPDU frame count
1.3.6.1.4.1.4756.20.451.40.1.75Columnf100AS1OamUnknowChRxRemoteAread-onlycurrentRemoteA device OAM Channel RX Unsupported OAMPDU frame count
1.3.6.1.4.1.4756.20.451.40.1.76Columnf100AS1FiberSpeedRemoteAread-onlycurrentRemoteA device Fiber speed : 1:100
1.3.6.1.4.1.4756.20.451.40.1.77Columnf100AS1MacLearningRemoteAread-writecurrentRemoteA device Mac learning : 0:Disable 1:Enable
1.3.6.1.4.1.4756.20.451.40.1.78Columnf100AS1Port1VIDRemoteAread-writecurrentRemoteA device Port 1 VID :
1.3.6.1.4.1.4756.20.451.40.1.79Columnf100AS1Port2VIDRemoteAread-writecurrentRemoteA device Port 2 VID :
1.3.6.1.4.1.4756.20.451.40.1.80Columnf100AS1Port1QinQRemoteAread-writecurrentRemoteA device Port 1 Q in Q Support : 1:Disable 2:Enable
1.3.6.1.4.1.4756.20.451.40.1.81Columnf100AS1Port2QinQRemoteAread-writecurrentRemoteA device Port 2 Q in Q Support : 1:Disable 2:Enable
1.3.6.1.4.1.4756.20.451.40.1.82Columnf100AS1VID1RemoteAread-writecurrentRemoteA device VID 1:
1.3.6.1.4.1.4756.20.451.40.1.83Columnf100AS1VID2RemoteAread-writecurrentRemoteA device VID 2:
1.3.6.1.4.1.4756.20.451.40.1.84Columnf100AS1VID3RemoteAread-writecurrentRemoteA device VID 3:
1.3.6.1.4.1.4756.20.451.40.1.85Columnf100AS1VID4RemoteAread-writecurrentRemoteA device VID 4:
1.3.6.1.4.1.4756.20.451.40.1.86Columnf100AS1VID5RemoteAread-writecurrentRemoteA device VID 5:
1.3.6.1.4.1.4756.20.451.40.1.87Columnf100AS1VID6RemoteAread-writecurrentRemoteA device VID 6:
1.3.6.1.4.1.4756.20.451.40.1.88Columnf100AS1VID7RemoteAread-writecurrentRemoteA device VID 7:
1.3.6.1.4.1.4756.20.451.40.1.89Columnf100AS1VID8RemoteAread-writecurrentRemoteA device VID 8:
1.3.6.1.4.1.4756.20.451.40.1.90Columnf100AS1VID9RemoteAread-writecurrentRemoteA device VID 9:
1.3.6.1.4.1.4756.20.451.40.1.91Columnf100AS1VID10RemoteAread-writecurrentRemoteA device VID 10:
1.3.6.1.4.1.4756.20.451.40.1.92Columnf100AS1VID11RemoteAread-writecurrentRemoteA device VID 11:
1.3.6.1.4.1.4756.20.451.40.1.93Columnf100AS1VID12RemoteAread-writecurrentRemoteA device VID 12:
1.3.6.1.4.1.4756.20.451.40.1.94Columnf100AS1VID13RemoteAread-writecurrentRemoteA device VID 13:
1.3.6.1.4.1.4756.20.451.40.1.95Columnf100AS1VID14RemoteAread-writecurrentRemoteA device VID 14:
1.3.6.1.4.1.4756.20.451.40.1.96Columnf100AS1VID15RemoteAread-writecurrentRemoteA device VID 15:
1.3.6.1.4.1.4756.20.451.40.1.97Columnf100AS1VID16RemoteAread-writecurrentRemoteA device VID 16:
1.3.6.1.4.1.4756.20.451.40.1.98Columnf100AS1Port1Member1RemoteAread-writecurrentRemoteA device card port 1 member: 0:Unmodify 1:Untagged 2:Tagged 3:Nonmember
1.3.6.1.4.1.4756.20.451.40.1.99Columnf100AS1Port1Member2RemoteAread-writecurrentRemoteA device card port 1 member 2: 0:Unmodify 1:Untagged 2:Tagged 3:Nonmember
1.3.6.1.4.1.4756.20.451.40.1.100Columnf100AS1Port1Member3RemoteAread-writecurrentRemoteA device card port 1 member 3: 0:Unmodify 1:Untagged 2:Tagged 3:Nonmember
1.3.6.1.4.1.4756.20.451.40.1.101Columnf100AS1Port1Member4RemoteAread-writecurrentRemoteA device card port 1 member 4: 0:Unmodify 1:Untagged 2:Tagged 3:Nonmember
1.3.6.1.4.1.4756.20.451.40.1.102Columnf100AS1Port1Member5RemoteAread-writecurrentRemoteA device card port 1 member 5: 0:Unmodify 1:Untagged 2:Tagged 3:Nonmember
1.3.6.1.4.1.4756.20.451.40.1.103Columnf100AS1Port1Member6RemoteAread-writecurrentRemoteA device card port 1 member 6: 0:Unmodify 1:Untagged 2:Tagged 3:Nonmember
1.3.6.1.4.1.4756.20.451.40.1.104Columnf100AS1Port1Member7RemoteAread-writecurrentRemoteA device card port 1 member 7: 0:Unmodify 1:Untagged 2:Tagged 3:Nonmember
1.3.6.1.4.1.4756.20.451.40.1.105Columnf100AS1Port1Member8RemoteAread-writecurrentRemoteA device card port 1 member 8: 0:Unmodify 1:Untagged 2:Tagged 3:Nonmember
1.3.6.1.4.1.4756.20.451.40.1.106Columnf100AS1Port1Member9RemoteAread-writecurrentRemoteA device card port 1 member 9: 0:Unmodify 1:Untagged 2:Tagged 3:Nonmember
1.3.6.1.4.1.4756.20.451.40.1.107Columnf100AS1Port1Member10RemoteAread-writecurrentRemoteA device card port 1 member 10: 0:Unmodify 1:Untagged 2:Tagged 3:Nonmember
1.3.6.1.4.1.4756.20.451.40.1.108Columnf100AS1Port1Member11RemoteAread-writecurrentRemoteA device card port 1 member 11: 0:Unmodify 1:Untagged 2:Tagged 3:Nonmember
1.3.6.1.4.1.4756.20.451.40.1.109Columnf100AS1Port1Member12RemoteAread-writecurrentRemoteA device card port 1 member 12: 0:Unmodify 1:Untagged 2:Tagged 3:Nonmember
1.3.6.1.4.1.4756.20.451.40.1.110Columnf100AS1Port1Member13RemoteAread-writecurrentRemoteA device card port 1 member 13: 0:Unmodify 1:Untagged 2:Tagged 3:Nonmember
1.3.6.1.4.1.4756.20.451.40.1.111Columnf100AS1Port1Member14RemoteAread-writecurrentRemoteA device card port 1 member 14: 0:Unmodify 1:Untagged 2:Tagged 3:Nonmember
1.3.6.1.4.1.4756.20.451.40.1.112Columnf100AS1Port1Member15RemoteAread-writecurrentRemoteA device card port 1 member 15: 0:Unmodify 1:Untagged 2:Tagged 3:Nonmember
1.3.6.1.4.1.4756.20.451.40.1.113Columnf100AS1Port1Member16RemoteAread-writecurrentRemoteA device card port 1 member 16: 0:Unmodify 1:Untagged 2:Tagged 3:Nonmember
1.3.6.1.4.1.4756.20.451.40.1.114Columnf100AS1Port2Member1RemoteAread-writecurrentRemoteA device card port 2 member: 0:Unmodify 1:Untagged 2:Tagged 3:Nonmember
1.3.6.1.4.1.4756.20.451.40.1.115Columnf100AS1Port2Member2RemoteAread-writecurrentRemoteA device card port 2 member 2: 0:Unmodify 1:Untagged 2:Tagged 3:Nonmember
1.3.6.1.4.1.4756.20.451.40.1.116Columnf100AS1Port2Member3RemoteAread-writecurrentRemoteA device card port 2 member 3: 0:Unmodify 1:Untagged 2:Tagged 3:Nonmember
1.3.6.1.4.1.4756.20.451.40.1.117Columnf100AS1Port2Member4RemoteAread-writecurrentRemoteA device card port 2 member 4: 0:Unmodify 1:Untagged 2:Tagged 3:Nonmember
1.3.6.1.4.1.4756.20.451.40.1.118Columnf100AS1Port2Member5RemoteAread-writecurrentRemoteA device card port 2 member 5: 0:Unmodify 1:Untagged 2:Tagged 3:Nonmember
1.3.6.1.4.1.4756.20.451.40.1.119Columnf100AS1Port2Member6RemoteAread-writecurrentRemoteA device card port 2 member 6: 0:Unmodify 1:Untagged 2:Tagged 3:Nonmember
1.3.6.1.4.1.4756.20.451.40.1.120Columnf100AS1Port2Member7RemoteAread-writecurrentRemoteA device card port 2 member 7: 0:Unmodify 1:Untagged 2:Tagged 3:Nonmember
1.3.6.1.4.1.4756.20.451.40.1.121Columnf100AS1Port2Member8RemoteAread-writecurrentRemoteA device card port 2 member 8: 0:Unmodify 1:Untagged 2:Tagged 3:Nonmember
1.3.6.1.4.1.4756.20.451.40.1.122Columnf100AS1Port2Member9RemoteAread-writecurrentRemoteA device card port 2 member 9: 0:Unmodify 1:Untagged 2:Tagged 3:Nonmember
1.3.6.1.4.1.4756.20.451.40.1.123Columnf100AS1Port2Member10RemoteAread-writecurrentRemoteA device card port 2 member 10: 0:Unmodify 1:Untagged 2:Tagged 3:Nonmember
1.3.6.1.4.1.4756.20.451.40.1.124Columnf100AS1Port2Member11RemoteAread-writecurrentRemoteA device card port 2 member 11: 0:Unmodify 1:Untagged 2:Tagged 3:Nonmember
1.3.6.1.4.1.4756.20.451.40.1.125Columnf100AS1Port2Member12RemoteAread-writecurrentRemoteA device card port 2 member 12: 0:Unmodify 1:Untagged 2:Tagged 3:Nonmember
1.3.6.1.4.1.4756.20.451.40.1.126Columnf100AS1Port2Member13RemoteAread-writecurrentRemoteA device card port 2 member 13: 0:Unmodify 1:Untagged 2:Tagged 3:Nonmember
1.3.6.1.4.1.4756.20.451.40.1.127Columnf100AS1Port2Member14RemoteAread-writecurrentRemoteA device card port 2 member 14: 0:Unmodify 1:Untagged 2:Tagged 3:Nonmember
1.3.6.1.4.1.4756.20.451.40.1.128Columnf100AS1Port2Member15RemoteAread-writecurrentRemoteA device card port 2 member 15: 0:Unmodify 1:Untagged 2:Tagged 3:Nonmember
1.3.6.1.4.1.4756.20.451.40.1.129Columnf100AS1Port2Member16RemoteAread-writecurrentRemoteA device card port 2 member 16: 0:Unmodify 1:Untagged 2:Tagged 3:Nonmember
1.3.6.1.4.1.4756.20.451.40.1.130Columnf100AS1IpAddressRemoteAread-writecurrentRemoteA device IP address
1.3.6.1.4.1.4756.20.451.40.1.131Columnf100AS1NetMaskRemoteAread-writecurrentRemoteA device Netmask
1.3.6.1.4.1.4756.20.451.40.1.132Columnf100AS1GateWayRemoteAread-writecurrentRemoteA device Gateway
1.3.6.1.4.1.4756.20.451.40.1.133Columnf100AS1SetDefaultRemoteAread-writecurrentRemoteA device set to default
1.3.6.1.4.1.4756.20.451.40.1.134Columnf100AS1ManagementVIDRemoteAread-writecurrentRemoteA device Management VID :
1.3.6.1.4.1.4756.20.451.40.1.135Columnf100AS1TagTypeRemoteAread-writecurrentRemoteA device Tag Type (HEX) :
1.3.6.1.4.1.4756.20.451.40.1.136Columnf100AS1FxLinkAlarmRemoteAread-writecurrentRemoteA device fiber link alarm 0:Disable 1:Enable
1.3.6.1.4.1.4756.20.451.40.1.137Columnf100AS1UtpLinkAlarmRemoteAread-writecurrentRemoteA device utp link alarm 0:Disable 1:Enable
1.3.6.1.4.1.4756.20.451.40.1.138Columnf100AS1RemoteTLPTRemoteAread-writecurrentRemoteA device Remote TLPT mode : 0:Disalbe 1:Remote
1.3.6.1.4.1.4756.20.452Nodef100AS1RemoteBCards
1.3.6.1.4.1.4756.20.452.40Tablef100AS1RemoteBTablenot-accessiblecurrentA list of RemoteB 100AS-1 card entries.
1.3.6.1.4.1.4756.20.452.40.1Rowf100AS1RemoteBEntrynot-accessiblecurrentAn entry containing management information applicable to a particular RemoteB f100AS-1 card.
1.3.6.1.4.1.4756.20.452.40.1.1Columnf100AS1ChassisIndexRemoteBread-onlycurrentA unique value for each chassis ID. For CH20, it is the chassis ID. For CH08, it is always 0.
1.3.6.1.4.1.4756.20.452.40.1.2Columnf100AS1SlotIndexRemoteBread-onlycurrentA unique value for each RemoteB card. It is the slot location number.
1.3.6.1.4.1.4756.20.452.40.1.3Columnf100AS1CardHWVerRemoteBread-onlycurrentRemoteB device card hardware version x.xxx
1.3.6.1.4.1.4756.20.452.40.1.4Columnf100AS1CardFWVerRemoteBread-onlycurrentRemoteB device card firmware version x.xxx
1.3.6.1.4.1.4756.20.452.40.1.5Columnf100AS1CardCPLDVerRemoteBread-onlycurrentRemoteB device card CPLD version x.xxx
1.3.6.1.4.1.4756.20.452.40.1.6Columnf100AS1CardFPGAVerRemoteBread-onlycurrentRemoteB device card FPGA version x.xxx
1.3.6.1.4.1.4756.20.452.40.1.7Columnf100AS1ModelRemoteBread-onlycurrentRemoteB 100AS-1 Serial Type
1.3.6.1.4.1.4756.20.452.40.1.8Columnf100AS1FiberLinkRemoteBread-onlycurrentRemoteB device card fiber port link status: 0:Down 1:Up
1.3.6.1.4.1.4756.20.452.40.1.9Columnf100AS1FiberOAMLoopedRemoteBread-onlycurrentRemoteB device card fiber port OAM looped: 0:Off 1:on
1.3.6.1.4.1.4756.20.452.40.1.10Columnf100AS1FiberLBTestRemoteBread-writecurrentForce remote device card to do fiber port LoopBack testing: 0:Off 1:Action
1.3.6.1.4.1.4756.20.452.40.1.11Columnf100AS1FiberOAMRLBStatusRemoteBread-onlycurrentRemoteB device card fiber port LoopBack testing status: 0:Off 1:Ok 2:Fail
1.3.6.1.4.1.4756.20.452.40.1.12Columnf100AS1FiberRemoPwrAbRemoteBread-onlycurrentRemoteB device card fiber port RemoteB Power status: 0:Abnormal 1:OK 2:None
1.3.6.1.4.1.4756.20.452.40.1.13Columnf100AS1FiberFEFRemoteBread-onlycurrentRemoteB device card fiber port FEF status: 0:Abnormal 1:OFF 2:Detected
1.3.6.1.4.1.4756.20.452.40.1.14Columnf100AS1FiberIngressRateRemoteBread-writecurrentRemoteB device card fiber Ingress Rate Limit: 0 = Unlimit input format: 64k(K),99m(M),99 If doesn't input the unit, the default was Mega. Limite Rate : 64K ~ 9…
1.3.6.1.4.1.4756.20.452.40.1.15Columnf100AS1FiberEgressRateRemoteBread-writecurrentRemoteB device card fiber Egress Rate Limit: 0 = Unlimit input format: 64k(K),99m(M),99 If doesn't input the unit, the default was Mega. Limite Rate : 64K ~ 99M
1.3.6.1.4.1.4756.20.452.40.1.16Columnf100AS1UtpLinkRemoteBread-onlycurrentRemoteB device card UTP port link status: 0:Down 1:Up
1.3.6.1.4.1.4756.20.452.40.1.17Columnf100AS1UtpNegoRemoteBread-writecurrentRemoteB device card UTP port negotiation status: 0:Manual 1:Auto
1.3.6.1.4.1.4756.20.452.40.1.18Columnf100AS1UtpSpeedRemoteBread-writecurrentRemoteB device card UTP port speed setting: 0:10 Base-T 1:100 Base-TX
1.3.6.1.4.1.4756.20.452.40.1.19Columnf100AS1UtpDuplexRemoteBread-writecurrentRemoteB device card UTP port duplex setting: 0:Half duplex mode 1:Full duplex mode
1.3.6.1.4.1.4756.20.452.40.1.20Columnf100AS1UtpSpeedStatusRemoteBread-onlycurrentRemoteB device card UTP port speed status: 0:10 Base-T 1:100 Base-TX
1.3.6.1.4.1.4756.20.452.40.1.21Columnf100AS1UtpDuplexStatusRemoteBread-onlycurrentRemoteB device card UTP port duplex status: 0:Half duplex mode 1:Full duplex mode
1.3.6.1.4.1.4756.20.452.40.1.22Columnf100AS1UtpIngressRateRemoteBread-writecurrentRemoteB device card utp Ingress Rate Limit: 0 = Unlimit input format: 64k(K),99m(M),99 If doesn't input the unit, the default was Mega. Limite Rate : 64K ~ 99M
1.3.6.1.4.1.4756.20.452.40.1.23Columnf100AS1UtpEgressRateRemoteBread-writecurrentRemoteB device card utp Egress Rate Limit: 0 = Unlimit input format: 64k(K),99m(M),99 If doesn't input the unit, the default was Mega. Limite Rate : 64K ~ 99M
1.3.6.1.4.1.4756.20.452.40.1.24Columnf100AS1DeviceResetRemoteBread-writecurrentForce RemoteB device card to reset mode: 0:Off 1:Action
1.3.6.1.4.1.4756.20.452.40.1.25Columnf100AS1UtpActiveRemoteBread-writecurrentRemoteB device UTP port active mode: 0:Disable 1:Enable
1.3.6.1.4.1.4756.20.452.40.1.26Columnf100AS1OamChModeRemoteBread-writecurrentRemoteB device OAM Channel mode: 0:Disable 1:passive 2:Active
1.3.6.1.4.1.4756.20.452.40.1.27Columnf100AS1OamMaxPDUsRemoteBread-writecurrentRemoteB device OAM max OAMPDU size: 60-1518 Octets
1.3.6.1.4.1.4756.20.452.40.1.28Columnf100AS1FiberAlsRemoteBread-writecurrentRemoteB device card port Auto Laser Shutdown mode: 0:Disable 1:Enable
1.3.6.1.4.1.4756.20.452.40.1.29Columnf100AS1PauseFrameRemoteBread-writecurrentRemoteB device card pause frame mode: 0:Disable 1:Enable
1.3.6.1.4.1.4756.20.452.40.1.30Columnf100AS1FHRModeRemoteBread-writecurrentRemoteB device card FHR Mode: 0:Disable 1:Enable
1.3.6.1.4.1.4756.20.452.40.1.31Columnf100AS1FiberLLFDepPortRemoteBread-writecurrentRemoteB device card port Link Loss Forwarding depends on port Ethernet Rx link: 0:don't care 1:selected
1.3.6.1.4.1.4756.20.452.40.1.32Columnf100AS1UtpLLFDepPortRemoteBread-writecurrentRemoteB device card port Link Loss Forwarding depends on port Fiber Rx link: 0:don't care 1:selected
1.3.6.1.4.1.4756.20.452.40.1.33Columnf100AS1AdvanceFunsRemoteBread-writecurrentRemoteB device card Switch functions mode: 0:Normal 5:Static 802.1Q VLAN 6:Spanning Tree Protocol 7:802.1Q VLAN Trunk 9:Q in Q VLAN 11:Spanning Tree Protocol &…
1.3.6.1.4.1.4756.20.452.40.1.34Columnf100AS1FiberInfoROM1RemoteBread-onlycurrentRemoteB device card port INFORemoteBOM information 1 valid: 0:Invalid 1:Valid
1.3.6.1.4.1.4756.20.452.40.1.35Columnf100AS1FiberInfoROM2RemoteBread-onlycurrentRemoteB device card port INFORemoteBOM information 2 valid: 0:Invalid 1:Valid(replacing D/D function
1.3.6.1.4.1.4756.20.452.40.1.36Columnf100AS1FiberInfoSN1RemoteBread-onlycurrentRemoteB device card port INFORemoteOM S/N 1
1.3.6.1.4.1.4756.20.452.40.1.37Columnf100AS1FiberInfoSN2RemoteBread-onlycurrentRemoteB device card port INFORemoteOM S/N 2
1.3.6.1.4.1.4756.20.452.40.1.38Columnf100AS1FiberDDRemoteBread-onlycurrentRemoteB device card fiber port Digital Diagnostic function: 0:No 1:Yes
1.3.6.1.4.1.4756.20.452.40.1.39Columnf100AS1FiberDDVendorRemoteBread-onlycurrentRemoteB device card fiber port D/D information: Vendor name
1.3.6.1.4.1.4756.20.452.40.1.40Columnf100AS1FiberDDPartNoRemoteBread-onlycurrentRemoteB device card fiber port D/D information: Vendor part number
1.3.6.1.4.1.4756.20.452.40.1.41Columnf100AS1FiberDDFiberTypeRemoteBread-onlycurrentRemoteB device card fiber port D/D information: Fiber Type
1.3.6.1.4.1.4756.20.452.40.1.42Columnf100AS1FiberDDWaveLenRemoteBread-onlycurrentRemoteB device card fiber port D/D information: Wave length
1.3.6.1.4.1.4756.20.452.40.1.43Columnf100AS1FiberDDWaveLen2RemoteBread-onlycurrentRemoteB device card fiber port D/D information: Wave length 2
1.3.6.1.4.1.4756.20.452.40.1.44Columnf100AS1FiberDDLinkLenRemoteBread-onlycurrentRemoteB device card fiber port D/D information: Link length
1.3.6.1.4.1.4756.20.452.40.1.45Columnf100AS1FiberDDLenUnitRemoteBread-onlycurrentRemoteB device card fiber port D/D information: Length Unit
1.3.6.1.4.1.4756.20.452.40.1.46Columnf100AS1FiberDDStatusRemoteBread-onlycurrentRemoteB device card fiber port D/D information: Status Support
1.3.6.1.4.1.4756.20.452.40.1.47Columnf100AS1FiberDDRxSensRemoteBread-onlycurrentRemoteB device card fiber port D/D information: Rx Sensitivity
1.3.6.1.4.1.4756.20.452.40.1.48Columnf100AS1FiberDDTxPWRRemoteBread-onlycurrentRemoteB device card fiber port D/D information: Tx power
1.3.6.1.4.1.4756.20.452.40.1.49Columnf100AS1FiberDDRxPWRRemoteBread-onlycurrentRemoteB device card fiber port D/D information: Rx power
1.3.6.1.4.1.4756.20.452.40.1.50Columnf100AS1FiberDDTempRemoteBread-onlycurrentRemoteB device card fiber port D/D information: Temperature in degree C
1.3.6.1.4.1.4756.20.452.40.1.51Columnf100AS1FiberDDPWRMarginRemoteBread-onlycurrentRemoteB device card fiber port D/D information: Power margin
1.3.6.1.4.1.4756.20.452.40.1.52Columnf100AS1FiberDDPWRLossRemoteBread-onlycurrentRemoteB device card fiber port D/D information: Power loss
1.3.6.1.4.1.4756.20.452.40.1.53Columnf100AS1ClrRMONCntsRemoteBread-writecurrentClear RemoteB device card RMON IN/OUT counters: 0:No action 1:Action
1.3.6.1.4.1.4756.20.452.40.1.54Columnf100AS1FiberRMONInRemoteBread-onlycurrentRemoteB device card port RMON IN counter.
1.3.6.1.4.1.4756.20.452.40.1.55Columnf100AS1FiberRMONOutRemoteBread-onlycurrentRemoteB device card port RMON OUT counter.
1.3.6.1.4.1.4756.20.452.40.1.56Columnf100AS1UtpRMONInRemoteBread-onlycurrentRemoteB device card port RMON IN counter.
1.3.6.1.4.1.4756.20.452.40.1.57Columnf100AS1UtpRMONOutRemoteBread-onlycurrentRemoteB device card port RMON OUT counter.
1.3.6.1.4.1.4756.20.452.40.1.58Columnf100AS1ClrOAMCntsRemoteBread-writecurrentClear RemoteB device card OAM counters: 0:No action 1:Action
1.3.6.1.4.1.4756.20.452.40.1.59Columnf100AS1IpModeRemoteBread-writecurrentOn Rack Ip Mode: 0:Enable 1:Disable
1.3.6.1.4.1.4756.20.452.40.1.60Columnf100AS1OamChTxRemoteBread-onlycurrentRemoteB device OAM Channel TX OAMPDU frame count
1.3.6.1.4.1.4756.20.452.40.1.61Columnf100AS1OamChRxRemoteBread-onlycurrentRemoteB device OAM Channel RX OAMPDU frame count
1.3.6.1.4.1.4756.20.452.40.1.62Columnf100AS1OamInfoChTxRemoteBread-onlycurrentRemoteB device OAM Channel TX Information OAMPDU frame count
1.3.6.1.4.1.4756.20.452.40.1.63Columnf100AS1OamInfoChRxRemoteBread-onlycurrentRemoteB device OAM Channel RX Information OAMPDU frame count
1.3.6.1.4.1.4756.20.452.40.1.64Columnf100AS1OamEventChTxRemoteBread-onlycurrentRemoteB device OAM Channel TX Event OAMPDU frame count
1.3.6.1.4.1.4756.20.452.40.1.65Columnf100AS1OamUniEvtChRxRemoteBread-onlycurrentRemoteB device OAM Channel RX Unique Event OAMPDU frame count
1.3.6.1.4.1.4756.20.452.40.1.66Columnf100AS1OamDupEvtChRxRemoteBread-onlycurrentRemoteB device OAM Channel RX Duplicate Event OAMPDU frame count
1.3.6.1.4.1.4756.20.452.40.1.67Columnf100AS1OamLbChTxRemoteBread-onlycurrentRemoteB device OAM Channel TX Loopback Control OAMPDU frame count
1.3.6.1.4.1.4756.20.452.40.1.68Columnf100AS1OamLbChRxRemoteBread-onlycurrentRemoteB device OAM Channel RX Loopback Control OAMPDU frame count
1.3.6.1.4.1.4756.20.452.40.1.69Columnf100AS1OamVarReqChTxRemoteBread-onlycurrentRemoteB device OAM Channel TX Variable Request OAMPDU frame count
1.3.6.1.4.1.4756.20.452.40.1.70Columnf100AS1OamVarReqChRxRemoteBread-onlycurrentRemoteB device OAM Channel RX Variable Request OAMPDU frame count
1.3.6.1.4.1.4756.20.452.40.1.71Columnf100AS1OamVarRspChTxRemoteBread-onlycurrentRemoteB device OAM Channel TX Variable Response OAMPDU frame count
1.3.6.1.4.1.4756.20.452.40.1.72Columnf100AS1OamVarRspChRxRemoteBread-onlycurrentRemoteB device OAM Channel RX Variable Response OAMPDU frame count
1.3.6.1.4.1.4756.20.452.40.1.73Columnf100AS1OamOuiChTxRemoteBread-onlycurrentRemoteB device OAM Channel TX OUI OAMPDU frame count
1.3.6.1.4.1.4756.20.452.40.1.74Columnf100AS1OamOuiChRxRemoteBread-onlycurrentRemoteB device OAM Channel RX OUI OAMPDU frame count
1.3.6.1.4.1.4756.20.452.40.1.75Columnf100AS1OamUnknowChRxRemoteBread-onlycurrentRemoteB device OAM Channel RX Unsupported OAMPDU frame count
1.3.6.1.4.1.4756.20.452.40.1.76Columnf100AS1FiberSpeedRemoteBread-onlycurrentRemoteB device Fiber speed : 1:100
1.3.6.1.4.1.4756.20.452.40.1.77Columnf100AS1MacLearningRemoteBread-writecurrentRemoteB device Mac learning : 0:Disable 1:Enable
1.3.6.1.4.1.4756.20.452.40.1.78Columnf100AS1Port1VIDRemoteBread-writecurrentRemoteB device Port 1 VID :
1.3.6.1.4.1.4756.20.452.40.1.79Columnf100AS1Port2VIDRemoteBread-writecurrentRemoteB device Port 2 VID :
1.3.6.1.4.1.4756.20.452.40.1.80Columnf100AS1Port1QinQRemoteBread-writecurrentRemoteB device Port 1 Q in Q Support : 1:Disable 2:Enable
1.3.6.1.4.1.4756.20.452.40.1.81Columnf100AS1Port2QinQRemoteBread-writecurrentRemoteB device Port 2 Q in Q Support : 1:Disable 2:Enable
1.3.6.1.4.1.4756.20.452.40.1.82Columnf100AS1VID1RemoteBread-writecurrentRemoteB device VID 1:
1.3.6.1.4.1.4756.20.452.40.1.83Columnf100AS1VID2RemoteBread-writecurrentRemoteB device VID 2:
1.3.6.1.4.1.4756.20.452.40.1.84Columnf100AS1VID3RemoteBread-writecurrentRemoteB device VID 3:
1.3.6.1.4.1.4756.20.452.40.1.85Columnf100AS1VID4RemoteBread-writecurrentRemoteB device VID 4:
1.3.6.1.4.1.4756.20.452.40.1.86Columnf100AS1VID5RemoteBread-writecurrentRemoteB device VID 5:
1.3.6.1.4.1.4756.20.452.40.1.87Columnf100AS1VID6RemoteBread-writecurrentRemoteB device VID 6:
1.3.6.1.4.1.4756.20.452.40.1.88Columnf100AS1VID7RemoteBread-writecurrentRemoteB device VID 7:
1.3.6.1.4.1.4756.20.452.40.1.89Columnf100AS1VID8RemoteBread-writecurrentRemoteB device VID 8:
1.3.6.1.4.1.4756.20.452.40.1.90Columnf100AS1VID9RemoteBread-writecurrentRemoteB device VID 9:
1.3.6.1.4.1.4756.20.452.40.1.91Columnf100AS1VID10RemoteBread-writecurrentRemoteB device VID 10:
1.3.6.1.4.1.4756.20.452.40.1.92Columnf100AS1VID11RemoteBread-writecurrentRemoteB device VID 11:
1.3.6.1.4.1.4756.20.452.40.1.93Columnf100AS1VID12RemoteBread-writecurrentRemoteB device VID 12:
1.3.6.1.4.1.4756.20.452.40.1.94Columnf100AS1VID13RemoteBread-writecurrentRemoteB device VID 13:
1.3.6.1.4.1.4756.20.452.40.1.95Columnf100AS1VID14RemoteBread-writecurrentRemoteB device VID 14:
1.3.6.1.4.1.4756.20.452.40.1.96Columnf100AS1VID15RemoteBread-writecurrentRemoteB device VID 15:
1.3.6.1.4.1.4756.20.452.40.1.97Columnf100AS1VID16RemoteBread-writecurrentRemoteB device VID 16:
1.3.6.1.4.1.4756.20.452.40.1.98Columnf100AS1Port1Member1RemoteBread-writecurrentRemoteB device card port 1 member: 0:Unmodify 1:Untagged 2:Tagged 3:Nonmember
1.3.6.1.4.1.4756.20.452.40.1.99Columnf100AS1Port1Member2RemoteBread-writecurrentRemoteB device card port 1 member 2: 0:Unmodify 1:Untagged 2:Tagged 3:Nonmember
1.3.6.1.4.1.4756.20.452.40.1.100Columnf100AS1Port1Member3RemoteBread-writecurrentRemoteB device card port 1 member 3: 0:Unmodify 1:Untagged 2:Tagged 3:Nonmember
1.3.6.1.4.1.4756.20.452.40.1.101Columnf100AS1Port1Member4RemoteBread-writecurrentRemoteB device card port 1 member 4: 0:Unmodify 1:Untagged 2:Tagged 3:Nonmember
1.3.6.1.4.1.4756.20.452.40.1.102Columnf100AS1Port1Member5RemoteBread-writecurrentRemoteB device card port 1 member 5: 0:Unmodify 1:Untagged 2:Tagged 3:Nonmember
1.3.6.1.4.1.4756.20.452.40.1.103Columnf100AS1Port1Member6RemoteBread-writecurrentRemoteB device card port 1 member 6: 0:Unmodify 1:Untagged 2:Tagged 3:Nonmember
1.3.6.1.4.1.4756.20.452.40.1.104Columnf100AS1Port1Member7RemoteBread-writecurrentRemoteB device card port 1 member 7: 0:Unmodify 1:Untagged 2:Tagged 3:Nonmember
1.3.6.1.4.1.4756.20.452.40.1.105Columnf100AS1Port1Member8RemoteBread-writecurrentRemoteB device card port 1 member 8: 0:Unmodify 1:Untagged 2:Tagged 3:Nonmember
1.3.6.1.4.1.4756.20.452.40.1.106Columnf100AS1Port1Member9RemoteBread-writecurrentRemoteB device card port 1 member 9: 0:Unmodify 1:Untagged 2:Tagged 3:Nonmember
1.3.6.1.4.1.4756.20.452.40.1.107Columnf100AS1Port1Member10RemoteBread-writecurrentRemoteB device card port 1 member 10: 0:Unmodify 1:Untagged 2:Tagged 3:Nonmember
1.3.6.1.4.1.4756.20.452.40.1.108Columnf100AS1Port1Member11RemoteBread-writecurrentRemoteB device card port 1 member 11: 0:Unmodify 1:Untagged 2:Tagged 3:Nonmember
1.3.6.1.4.1.4756.20.452.40.1.109Columnf100AS1Port1Member12RemoteBread-writecurrentRemoteB device card port 1 member 12: 0:Unmodify 1:Untagged 2:Tagged 3:Nonmember
1.3.6.1.4.1.4756.20.452.40.1.110Columnf100AS1Port1Member13RemoteBread-writecurrentRemoteB device card port 1 member 13: 0:Unmodify 1:Untagged 2:Tagged 3:Nonmember
1.3.6.1.4.1.4756.20.452.40.1.111Columnf100AS1Port1Member14RemoteBread-writecurrentRemoteB device card port 1 member 14: 0:Unmodify 1:Untagged 2:Tagged 3:Nonmember
1.3.6.1.4.1.4756.20.452.40.1.112Columnf100AS1Port1Member15RemoteBread-writecurrentRemoteB device card port 1 member 15: 0:Unmodify 1:Untagged 2:Tagged 3:Nonmember
1.3.6.1.4.1.4756.20.452.40.1.113Columnf100AS1Port1Member16RemoteBread-writecurrentRemoteB device card port 1 member 16: 0:Unmodify 1:Untagged 2:Tagged 3:Nonmember
1.3.6.1.4.1.4756.20.452.40.1.114Columnf100AS1Port2Member1RemoteBread-writecurrentRemoteB device card port 2 member: 0:Unmodify 1:Untagged 2:Tagged 3:Nonmember
1.3.6.1.4.1.4756.20.452.40.1.115Columnf100AS1Port2Member2RemoteBread-writecurrentRemoteB device card port 2 member 2: 0:Unmodify 1:Untagged 2:Tagged 3:Nonmember
1.3.6.1.4.1.4756.20.452.40.1.116Columnf100AS1Port2Member3RemoteBread-writecurrentRemoteB device card port 2 member 3: 0:Unmodify 1:Untagged 2:Tagged 3:Nonmember
1.3.6.1.4.1.4756.20.452.40.1.117Columnf100AS1Port2Member4RemoteBread-writecurrentRemoteB device card port 2 member 4: 0:Unmodify 1:Untagged 2:Tagged 3:Nonmember
1.3.6.1.4.1.4756.20.452.40.1.118Columnf100AS1Port2Member5RemoteBread-writecurrentRemoteB device card port 2 member 5: 0:Unmodify 1:Untagged 2:Tagged 3:Nonmember
1.3.6.1.4.1.4756.20.452.40.1.119Columnf100AS1Port2Member6RemoteBread-writecurrentRemoteB device card port 2 member 6: 0:Unmodify 1:Untagged 2:Tagged 3:Nonmember
1.3.6.1.4.1.4756.20.452.40.1.120Columnf100AS1Port2Member7RemoteBread-writecurrentRemoteB device card port 2 member 7: 0:Unmodify 1:Untagged 2:Tagged 3:Nonmember
1.3.6.1.4.1.4756.20.452.40.1.121Columnf100AS1Port2Member8RemoteBread-writecurrentRemoteB device card port 2 member 8: 0:Unmodify 1:Untagged 2:Tagged 3:Nonmember
1.3.6.1.4.1.4756.20.452.40.1.122Columnf100AS1Port2Member9RemoteBread-writecurrentRemoteB device card port 2 member 9: 0:Unmodify 1:Untagged 2:Tagged 3:Nonmember
1.3.6.1.4.1.4756.20.452.40.1.123Columnf100AS1Port2Member10RemoteBread-writecurrentRemoteB device card port 2 member 10: 0:Unmodify 1:Untagged 2:Tagged 3:Nonmember
1.3.6.1.4.1.4756.20.452.40.1.124Columnf100AS1Port2Member11RemoteBread-writecurrentRemoteB device card port 2 member 11: 0:Unmodify 1:Untagged 2:Tagged 3:Nonmember
1.3.6.1.4.1.4756.20.452.40.1.125Columnf100AS1Port2Member12RemoteBread-writecurrentRemoteB device card port 2 member 12: 0:Unmodify 1:Untagged 2:Tagged 3:Nonmember
1.3.6.1.4.1.4756.20.452.40.1.126Columnf100AS1Port2Member13RemoteBread-writecurrentRemoteB device card port 2 member 13: 0:Unmodify 1:Untagged 2:Tagged 3:Nonmember
1.3.6.1.4.1.4756.20.452.40.1.127Columnf100AS1Port2Member14RemoteBread-writecurrentRemoteB device card port 2 member 14: 0:Unmodify 1:Untagged 2:Tagged 3:Nonmember
1.3.6.1.4.1.4756.20.452.40.1.128Columnf100AS1Port2Member15RemoteBread-writecurrentRemoteB device card port 2 member 15: 0:Unmodify 1:Untagged 2:Tagged 3:Nonmember
1.3.6.1.4.1.4756.20.452.40.1.129Columnf100AS1Port2Member16RemoteBread-writecurrentRemoteB device card port 2 member 16: 0:Unmodify 1:Untagged 2:Tagged 3:Nonmember
1.3.6.1.4.1.4756.20.452.40.1.130Columnf100AS1IpAddressRemoteBread-writecurrentRemoteB device IP address
1.3.6.1.4.1.4756.20.452.40.1.131Columnf100AS1NetMaskRemoteBread-writecurrentRemoteB device Netmask
1.3.6.1.4.1.4756.20.452.40.1.132Columnf100AS1GateWayRemoteBread-writecurrentRemoteB device Gateway
1.3.6.1.4.1.4756.20.452.40.1.133Columnf100AS1SetDefaultRemoteBread-writecurrentRemoteB device set to default
1.3.6.1.4.1.4756.20.452.40.1.134Columnf100AS1ManagementVIDRemoteBread-writecurrentRemoteB device Management VID :
1.3.6.1.4.1.4756.20.452.40.1.135Columnf100AS1TagTypeRemoteBread-writecurrentRemoteB device Tag Type (HEX) :
1.3.6.1.4.1.4756.20.452.40.1.136Columnf100AS1FxLinkAlarmRemoteBread-writecurrentRemoteB device fiber link alarm 0:Disable 1:Enable
1.3.6.1.4.1.4756.20.452.40.1.137Columnf100AS1UtpLinkAlarmRemoteBread-writecurrentRemoteB device utp link alarm 0:Disable 1:Enable
1.3.6.1.4.1.4756.20.452.40.1.138Columnf100AS1RemoteTLPTRemoteBread-writecurrentRemoteB device Remote TLPT mode : 0:Disalbe 1:Remote
1.3.6.1.4.1.4756.20.460Nodefxofxs4LocalCards
1.3.6.1.4.1.4756.20.460.20Tablefxofxs4LocalTablenot-accessiblecurrentA list of local FRM220-FXO/FXS-4 card entries. The number of entries is fxoFXS-No-L.
1.3.6.1.4.1.4756.20.460.20.1Rowfxofxs4LocalEntrynot-accessiblecurrentAn entry containing management information applicable to a particular local FRM220-FXO/FXS-4 card.
1.3.6.1.4.1.4756.20.460.20.1.1Columnfxofxs4ChassisIndexLocalread-onlycurrentA unique value for each local card. It is the chassis location number.
1.3.6.1.4.1.4756.20.460.20.1.2Columnfxofxs4SlotIndexLocalread-onlycurrentA unique value for each local card. It is the slot location number.
1.3.6.1.4.1.4756.20.460.20.1.3Columnfxofxs4CardHWVerLocalread-onlycurrentLocal FRM220-FXO/FXS-4 card hardware version x.xxx
1.3.6.1.4.1.4756.20.460.20.1.4Columnfxofxs4CardFWVerLocalread-onlycurrentLocal FRM220-FXO/FXS-4 card firmware version x.xxx
1.3.6.1.4.1.4756.20.460.20.1.5Columnfxofxs4CardCPLDVerLocalread-onlycurrentLocal FRM220-FXO/FXS card CPLD version x.xxx
1.3.6.1.4.1.4756.20.460.20.1.6Columnfxofxs4CardFPGAVerLocalread-onlycurrentLocal FRM220-FXO/FXS card FPGA version x.xxx
1.3.6.1.4.1.4756.20.460.20.1.7Columnfxofxs4ModelLocalread-onlycurrentLocal FRM220-FXO/FXS-4 Mode: 0:FRM220-FXO-4 1:FRM220-FXS-4
1.3.6.1.4.1.4756.20.460.20.1.8Columnfxofxs4FxLinkLocalread-onlycurrentLocal FRM220-FXO/FXS-4 fiber link state: 0:Link Down 1:Link Up
1.3.6.1.4.1.4756.20.460.20.1.9Columnfxofxs4FxFEFLocalread-onlycurrentLocal FRM220-FXO/FXS-4 card fiber detected Far End Fault: 0:Off 1:Detected
1.3.6.1.4.1.4756.20.460.20.1.10Columnfxofxs4FxDDLocalread-onlycurrentLocal FRM220-FXO/FXS-4 card fiber Digital Diagnostic function: 0:No 1:Yes
1.3.6.1.4.1.4756.20.460.20.1.11Columnfxofxs4FxPortActiveLocalread-writecurrentLocal FRM220-FXO/FXS-4 card Port Active: 0:Disable 1:Enable
1.3.6.1.4.1.4756.20.460.20.1.12Columnfxofxs4FxALSModeLocalread-writecurrentLocal FRM220-FXO/FXS-4 card Auto Laser Shutdown : 0:Disable 1:Enable
1.3.6.1.4.1.4756.20.460.20.1.13Columnfxofxs4FxBitErrorCounterLocalread-onlycurrentLocal FRM220-FXO/FXS-4 card Bert Bit Error Counter
1.3.6.1.4.1.4756.20.460.20.1.14Columnfxofxs4FxInsertOneBitErrorLocalread-writecurrentLocal FRM220-FXO/FXS-4 card Bert Insert One Bit Error: 0:Off 1:Action
1.3.6.1.4.1.4756.20.460.20.1.15Columnfxofxs4FxClearBitErrorCounterLocalread-writecurrentLocal FRM220-FXO/FXS-4 card Clear Bit Error Counter: 0:Off 1:Action
1.3.6.1.4.1.4756.20.460.20.1.16Columnfxofxs4Channel1ActiveStsLocalread-onlycurrentLocal FRM220-FXO/FXS-4 Channel 1 Active State: 0:NO 1:YES
1.3.6.1.4.1.4756.20.460.20.1.17Columnfxofxs4Channel1RingStsLocalread-onlycurrentLocal FRM220-FXO/FXS-4 card Channel 1 Ring State: 0:No Ring 1:Ringing
1.3.6.1.4.1.4756.20.460.20.1.18Columnfxofxs4Channel1HookLocalread-onlycurrentLocal FRM220-FXO/FXS-4 card Channel 1 Hook: 0:on-hook 1:off-hook
1.3.6.1.4.1.4756.20.460.20.1.19Columnfxofxs4Channel2ActiveStsLocalread-onlycurrentLocal FRM220-FXO/FXS-4 Channel 2 Active State: 0:NO 1:YES
1.3.6.1.4.1.4756.20.460.20.1.20Columnfxofxs4Channel2RingStsLocalread-onlycurrentLocal FRM220-FXO/FXS-4 card Channel 2 Ring State: 0:No Ring 1:Ringing
1.3.6.1.4.1.4756.20.460.20.1.21Columnfxofxs4Channel2HookLocalread-onlycurrentLocal FRM220-FXO/FXS-4 card Channel 2 Hook: 0:on-hook 1:off-hook
1.3.6.1.4.1.4756.20.460.20.1.22Columnfxofxs4Channel3ActiveStsLocalread-onlycurrentLocal FRM220-FXO/FXS-4 Channel 3 Active State: 0:NO 1:YES
1.3.6.1.4.1.4756.20.460.20.1.23Columnfxofxs4Channel3RingStsLocalread-onlycurrentLocal FRM220-FXO/FXS-4 card Channel 3 Ring State: 0:No Ring 1:Ringing
1.3.6.1.4.1.4756.20.460.20.1.24Columnfxofxs4Channel3HookLocalread-onlycurrentLocal FRM220-FXO/FXS-4 card Channel 3 Hook: 0:on-hook 1:off-hook
1.3.6.1.4.1.4756.20.460.20.1.25Columnfxofxs4Channel4ActiveStsLocalread-onlycurrentLocal FRM220-FXO/FXS-4 Channel 4 Active State: 0:NO 1:YES
1.3.6.1.4.1.4756.20.460.20.1.26Columnfxofxs4Channel4RingStsLocalread-onlycurrentLocal FRM220-FXO/FXS-4 card Channel 4 Ring State: 0:No Ring 1:Ringing
1.3.6.1.4.1.4756.20.460.20.1.27Columnfxofxs4Channel4HookLocalread-onlycurrentLocal FRM220-FXO/FXS-4 card Channel 4 Hook: 0:on-hook 1:off-hook
1.3.6.1.4.1.4756.20.460.20.1.28Columnfxofxs4RingFreqLocalread-writecurrentLocal FRM220-FXO/FXS-4 card ring frequency FXO-4: 0: 50/55Hz 1: 40/45Hz 2: 30/35Hz 3: 20/25Hz FXS-4: 4: 55Hz 5: 50Hz 6: 45Hz 7: 40Hz 8: 35Hz 9: 30Hz 10: 25Hz 1…
1.3.6.1.4.1.4756.20.460.20.1.29Columnfxofxs4AreaModeLocalread-writecurrentLocal FRM220-FXO/FXS-4 card area mode (FXO-4 only) 0: Area1 1: Area2 2: Area3 3: Area4 4: Area5 5: Area6 6: Area7 7: Area8 8: Area9 9: Area10 10: Area11 11: Ar…
1.3.6.1.4.1.4756.20.460.20.1.30Columnfxofxs4RingingStyleLocalread-writecurrentLocal FRM220-FXO/FXS-4 card ringing style (FXS-4 only) 0: On:0.40s Off:0.20s 1: On:0.75s Off:7.50s 2: On:1.00s Off:3.00s 3: On:1.00s Off:4.00s 4: On:1.00s Off:…
1.3.6.1.4.1.4756.20.460.20.1.31Columnfxofxs4RingONLocalread-writecurrentLocal FRM220-FXO/FXS-4 card ring on (FXS-4 only) Range: 1 ms ~ 8190 ms
1.3.6.1.4.1.4756.20.460.20.1.32Columnfxofxs4RingOFFLocalread-writecurrentLocal FRM220-FXO/FXS-4 card ring off (FXS-4 only) Range: 1 ms ~ 8190 ms
1.3.6.1.4.1.4756.20.460.20.1.33Columnfxofxs4PortResetLocalread-writecurrentForce remote FRM220-FXO/FXS-4 card reset mode: 0:Off 1:Action
1.3.6.1.4.1.4756.20.460.20.1.34Columnfxofxs4SetDefaultLocalread-writecurrentForce remote FRM220-FXO/FXS-4 card to default status: 0:Off 1:Action
1.3.6.1.4.1.4756.20.460.20.1.35Columnfxofxs4DDVendorLocalread-onlycurrentLocal FRM220-FXO/FXS-4 card fiber D/D information: Vendor name
1.3.6.1.4.1.4756.20.460.20.1.36Columnfxofxs4DDPartNoLocalread-onlycurrentLocal FRM220-FXO/FXS-4 card fiber D/D information: Vendor part number
1.3.6.1.4.1.4756.20.460.20.1.37Columnfxofxs4DDFiberTypeLocalread-onlycurrentLocal FRM220-FXO/FXS-4 card fiber D/D information: Fiber Type
1.3.6.1.4.1.4756.20.460.20.1.38Columnfxofxs4DDWaveLenLocalread-onlycurrentLocal FRM220-FXO/FXS-4 card fiber D/D information: Wave length
1.3.6.1.4.1.4756.20.460.20.1.39Columnfxofxs4DDWaveLen2Localread-onlycurrentLocal FRM220-FXO/FXS-4 card fiber D/D information: Wave length 2
1.3.6.1.4.1.4756.20.460.20.1.40Columnfxofxs4DDLinkLenLocalread-onlycurrentLocal FRM220-FXO/FXS-4 card fiber D/D information: Link length
1.3.6.1.4.1.4756.20.460.20.1.41Columnfxofxs4DDLenUnitLocalread-onlycurrentLocal FRM220-FXO/FXS-4 card fiber D/D information: Length Unit
1.3.6.1.4.1.4756.20.460.20.1.42Columnfxofxs4DDStatusLocalread-onlycurrentLocal FRM220-FXO/FXS-4 card fiber D/D information: Status Support
1.3.6.1.4.1.4756.20.460.20.1.43Columnfxofxs4DDRxSensLocalread-onlycurrentLocal FRM220-FXO/FXS-4 card fiber D/D information: Rx Sensitivity
1.3.6.1.4.1.4756.20.460.20.1.44Columnfxofxs4DDTxPwrLocalread-onlycurrentLocal FRM220-FXO/FXS-4 card fiber D/D information: Tx power
1.3.6.1.4.1.4756.20.460.20.1.45Columnfxofxs4DDRxPwrLocalread-onlycurrentLocal FRM220-FXO/FXS-4 card fiber D/D information: Rx power
1.3.6.1.4.1.4756.20.460.20.1.46Columnfxofxs4DDTempLocalread-onlycurrentLocal FRM220-FXO/FXS-4 card fiber D/D information: Temperature in degree C
1.3.6.1.4.1.4756.20.460.20.1.47Columnfxofxs4DDPwrMarginLocalread-onlycurrentLocal FRM220-FXO/FXS-4 card fiber D/D information: Power margin
1.3.6.1.4.1.4756.20.460.20.1.48Columnfxofxs4DDPwrLossLocalread-onlycurrentLocal FRM220-FXO/FXS-4 card fiber D/D information: Power loss
1.3.6.1.4.1.4756.20.460.20.1.49Columnfxofxs4FxLedStatusLocalread-onlycurrentLocal FRM220-FXO/FXS-4 card fiber led status: 0: OFF 1: Flash 2: ON
1.3.6.1.4.1.4756.20.461Nodefxofxs4RemoteCards
1.3.6.1.4.1.4756.20.461.20Tablefxofxs4RemoteTablenot-accessiblecurrentA list of Remote FRM220-FXO/FXS-4 card entries. The number of entries is fxoFXS-No-L.
1.3.6.1.4.1.4756.20.461.20.1Rowfxofxs4RemoteEntrynot-accessiblecurrentAn entry containing management information applicable to a particular Remote FRM220-FXO/FXS-4 card.
1.3.6.1.4.1.4756.20.461.20.1.1Columnfxofxs4ChassisIndexRemoteread-onlycurrentA unique value for each Remote card. It is the chassis location number.
1.3.6.1.4.1.4756.20.461.20.1.2Columnfxofxs4SlotIndexRemoteread-onlycurrentA unique value for each Remote card. It is the slot location number.
1.3.6.1.4.1.4756.20.461.20.1.3Columnfxofxs4CardHWVerRemoteread-onlycurrentRemote FRM220-FXO/FXS-4 card hardware version x.xxx
1.3.6.1.4.1.4756.20.461.20.1.4Columnfxofxs4CardFWVerRemoteread-onlycurrentRemote FRM220-FXO/FXS-4 card firmware version x.xxx
1.3.6.1.4.1.4756.20.461.20.1.5Columnfxofxs4CardCPLDVerRemoteread-onlycurrentRemote FRM220-FXO/FXS card CPLD version x.xxx
1.3.6.1.4.1.4756.20.461.20.1.6Columnfxofxs4CardFPGAVerRemoteread-onlycurrentRemote FRM220-FXO/FXS card FPGA version x.xxx
1.3.6.1.4.1.4756.20.461.20.1.7Columnfxofxs4ModelRemoteread-onlycurrentRemote FRM220-FXO/FXS-4 Mode: 0:FRM220-FXO-4 1:FRM220-FXS-4
1.3.6.1.4.1.4756.20.461.20.1.8Columnfxofxs4FxLinkRemoteread-onlycurrentRemote FRM220-FXO/FXS-4 fiber link state: 0:Link Down 1:Link Up
1.3.6.1.4.1.4756.20.461.20.1.9Columnfxofxs4FxFEFRemoteread-onlycurrentRemote FRM220-FXO/FXS-4 card fiber detected Far End Fault: 0:Off 1:Detected
1.3.6.1.4.1.4756.20.461.20.1.10Columnfxofxs4FxDDRemoteread-onlycurrentRemote FRM220-FXO/FXS-4 card fiber Digital Diagnostic function: 0:No 1:Yes
1.3.6.1.4.1.4756.20.461.20.1.11Columnfxofxs4FxPortActiveRemoteread-onlycurrentRemote FRM220-FXO/FXS-4 card Port Active: 0:Disable 1:Enable
1.3.6.1.4.1.4756.20.461.20.1.12Columnfxofxs4FxALSModeRemoteread-writecurrentRemote FRM220-FXO/FXS-4 card Auto Laser Shutdown : 0:Disable 1:Enable
1.3.6.1.4.1.4756.20.461.20.1.13Columnfxofxs4FxBitErrorCounterRemoteread-onlycurrentRemote FRM220-FXO/FXS-4 card Bert Bit Error Counter
1.3.6.1.4.1.4756.20.461.20.1.14Columnfxofxs4FxInsertOneBitErrorRemoteread-writecurrentRemote FRM220-FXO/FXS-4 card Bert Insert One Bit Error: 0:Off 1:Action
1.3.6.1.4.1.4756.20.461.20.1.15Columnfxofxs4FxClearBitErrorCounterRemoteread-writecurrentRemote FRM220-FXO/FXS-4 card Clear Bit Error Counter: 0:Off 1:Action
1.3.6.1.4.1.4756.20.461.20.1.16Columnfxofxs4Channel1ActiveStsRemoteread-onlycurrentRemote FRM220-FXO/FXS-4 Channel 1 Active State: 0:NO 1:YES
1.3.6.1.4.1.4756.20.461.20.1.17Columnfxofxs4Channel1RingStsRemoteread-onlycurrentRemote FRM220-FXO/FXS-4 card Channel 1 Ring State: 0:No Ring 1:Ringing
1.3.6.1.4.1.4756.20.461.20.1.18Columnfxofxs4Channel1HookRemoteread-onlycurrentRemote FRM220-FXO/FXS-4 card Channel 1 Hook: 0:on-hook 1:off-hook
1.3.6.1.4.1.4756.20.461.20.1.19Columnfxofxs4Channel2ActiveStsRemoteread-onlycurrentRemote FRM220-FXO/FXS-4 Channel 2 Active State: 0:NO 1:YES
1.3.6.1.4.1.4756.20.461.20.1.20Columnfxofxs4Channel2RingStsRemoteread-onlycurrentRemote FRM220-FXO/FXS-4 card Channel 2 Ring State: 0:No Ring 1:Ringing
1.3.6.1.4.1.4756.20.461.20.1.21Columnfxofxs4Channel2HookRemoteread-onlycurrentRemote FRM220-FXO/FXS-4 card Channel 2 Hook: 0:on-hook 1:off-hook
1.3.6.1.4.1.4756.20.461.20.1.22Columnfxofxs4Channel3ActiveStsRemoteread-onlycurrentRemote FRM220-FXO/FXS-4 Channel 3 Active State: 0:NO 1:YES
1.3.6.1.4.1.4756.20.461.20.1.23Columnfxofxs4Channel3RingStsRemoteread-onlycurrentRemote FRM220-FXO/FXS-4 card Channel 3 Ring State: 0:No Ring 1:Ringing
1.3.6.1.4.1.4756.20.461.20.1.24Columnfxofxs4Channel3HookRemoteread-onlycurrentRemote FRM220-FXO/FXS-4 card Channel 3 Hook: 0:on-hook 1:off-hook
1.3.6.1.4.1.4756.20.461.20.1.25Columnfxofxs4Channel4ActiveStsRemoteread-onlycurrentRemote FRM220-FXO/FXS-4 Channel 4 Active State: 0:NO 1:YES
1.3.6.1.4.1.4756.20.461.20.1.26Columnfxofxs4Channel4RingStsRemoteread-onlycurrentRemote FRM220-FXO/FXS-4 card Channel 4 Ring State: 0:No Ring 1:Ringing
1.3.6.1.4.1.4756.20.461.20.1.27Columnfxofxs4Channel4HookRemoteread-onlycurrentRemote FRM220-FXO/FXS-4 card Channel 4 Hook: 0:on-hook 1:off-hook
1.3.6.1.4.1.4756.20.461.20.1.28Columnfxofxs4RingFreqRemoteread-writecurrentRemote FRM220-FXO/FXS-4 card ring frequency FXO-4: 0: 50/55Hz 1: 40/45Hz 2: 30/35Hz 3: 20/25Hz FXS-4: 4: 55Hz 5: 50Hz 6: 45Hz 7: 40Hz 8: 35Hz 9: 30Hz 10: 25Hz …
1.3.6.1.4.1.4756.20.461.20.1.29Columnfxofxs4AreaModeRemoteread-writecurrentRemote FRM220-FXO/FXS-4 card area mode (FXO-4 only) 0: Area1 1: Area2 2: Area3 3: Area4 4: Area5 5: Area6 6: Area7 7: Area8 8: Area9 9: Area10 10: Area11 11: A…
1.3.6.1.4.1.4756.20.461.20.1.30Columnfxofxs4RingingStyleRemoteread-writecurrentRemote FRM220-FXO/FXS-4 card ringing style (FXS-4 only) 0: On:0.40s Off:0.20s 1: On:0.75s Off:7.50s 2: On:1.00s Off:3.00s 3: On:1.00s Off:4.00s 4: On:1.00s Off…
1.3.6.1.4.1.4756.20.461.20.1.31Columnfxofxs4RingONRemoteread-writecurrentRemote FRM220-FXO/FXS-4 card ring on (FXS-4 only) Range: 1 ms ~ 8190 ms
1.3.6.1.4.1.4756.20.461.20.1.32Columnfxofxs4RingOFFRemoteread-writecurrentRemote FRM220-FXO/FXS-4 card ring off (FXS-4 only) Range: 1 ms ~ 8190 ms
1.3.6.1.4.1.4756.20.461.20.1.33Columnfxofxs4PortResetRemoteread-writecurrentForce remote FRM220-FXO/FXS-4 card to reset mode: 0:Off 1:Action
1.3.6.1.4.1.4756.20.461.20.1.34Columnfxofxs4SetDefaultRemoteread-writecurrentForce remote FRM220-FXO/FXS-4 card to default status: 0:Off 1:Action
1.3.6.1.4.1.4756.20.461.20.1.35Columnfxofxs4DDVendorRemoteread-onlycurrentRemote FRM220-FXO/FXS-4 card fiber D/D information: Vendor name
1.3.6.1.4.1.4756.20.461.20.1.36Columnfxofxs4DDPartNoRemoteread-onlycurrentRemote FRM220-FXO/FXS-4 card fiber D/D information: Vendor part number
1.3.6.1.4.1.4756.20.461.20.1.37Columnfxofxs4DDFiberTypeRemoteread-onlycurrentRemote FRM220-FXO/FXS-4 card fiber D/D information: Fiber Type
1.3.6.1.4.1.4756.20.461.20.1.38Columnfxofxs4DDWaveLenRemoteread-onlycurrentRemote FRM220-FXO/FXS-4 card fiber D/D information: Wave length
1.3.6.1.4.1.4756.20.461.20.1.39Columnfxofxs4DDWaveLen2Remoteread-onlycurrentRemote FRM220-FXO/FXS-4 card fiber D/D information: Wave length 2
1.3.6.1.4.1.4756.20.461.20.1.40Columnfxofxs4DDLinkLenRemoteread-onlycurrentRemote FRM220-FXO/FXS-4 card fiber D/D information: Link length
1.3.6.1.4.1.4756.20.461.20.1.41Columnfxofxs4DDLenUnitRemoteread-onlycurrentRemote FRM220-FXO/FXS-4 card fiber D/D information: Length Unit
1.3.6.1.4.1.4756.20.461.20.1.42Columnfxofxs4DDStatusRemoteread-onlycurrentRemote FRM220-FXO/FXS-4 card fiber D/D information: Status Support
1.3.6.1.4.1.4756.20.461.20.1.43Columnfxofxs4DDRxSensRemoteread-onlycurrentRemote FRM220-FXO/FXS-4 card fiber D/D information: Rx Sensitivity
1.3.6.1.4.1.4756.20.461.20.1.44Columnfxofxs4DDTxPwrRemoteread-onlycurrentRemote FRM220-FXO/FXS-4 card fiber D/D information: Tx power
1.3.6.1.4.1.4756.20.461.20.1.45Columnfxofxs4DDRxPwrRemoteread-onlycurrentRemote FRM220-FXO/FXS-4 card fiber D/D information: Rx power
1.3.6.1.4.1.4756.20.461.20.1.46Columnfxofxs4DDTempRemoteread-onlycurrentRemote FRM220-FXO/FXS-4 card fiber D/D information: Temperature in degree C
1.3.6.1.4.1.4756.20.461.20.1.47Columnfxofxs4DDPwrMarginRemoteread-onlycurrentRemote FRM220-FXO/FXS-4 card fiber D/D information: Power margin
1.3.6.1.4.1.4756.20.461.20.1.48Columnfxofxs4DDPwrLossRemoteread-onlycurrentRemote FRM220-FXO/FXS-4 card fiber D/D information: Power loss
1.3.6.1.4.1.4756.20.461.20.1.49Columnfxofxs4FxLedStatusRemoteread-onlycurrentRemote FRM220-FXO/FXS-4 card fiber led status: 0: OFF 1: Flash 2: ON
1.3.6.1.4.1.4756.20.470NodegfomLocalCards
1.3.6.1.4.1.4756.20.470.20TablegfomLocalTablenot-accessiblecurrentA list of Local FRM220-GFOM04/08 card entries.
1.3.6.1.4.1.4756.20.470.20.1RowgfomLocalEntrynot-accessiblecurrentAn entry containing management information applicable to a particular Local FRM220-GFOM04/08 card.
1.3.6.1.4.1.4756.20.470.20.1.1ColumngfomChassisIndexLocalread-onlycurrentA unique value for each local card. It is the chassis location number.
1.3.6.1.4.1.4756.20.470.20.1.2ColumngfomSlotIndexLocalread-onlycurrentA unique value for each local card. It is the slot location number.
1.3.6.1.4.1.4756.20.470.20.1.3ColumngfomCardHWVerLocalread-onlycurrentLocal FRM220-GFOM04/08 card hardware version x.xxx
1.3.6.1.4.1.4756.20.470.20.1.4ColumngfomCardFWVerLocalread-onlycurrentLocal FRM220-GFOM04/08 card firmware version x.xxx
1.3.6.1.4.1.4756.20.470.20.1.5ColumngfomCardCPLDVerLocalread-onlycurrentLocal FRM220-GFOM04/08 card CPLD version x.xxx
1.3.6.1.4.1.4756.20.470.20.1.6ColumngfomCardFPGAVerLocalread-onlycurrentLocal FRM220-GFOM04/08 card FPGA version x.xxx
1.3.6.1.4.1.4756.20.470.20.1.7ColumngfomModelLocalread-onlycurrentLocal FRM220-GFOM04/08 Mode: 0:FRM220-GFOM04 1:FRM220-GFOM08
1.3.6.1.4.1.4756.20.470.20.1.8ColumngfomFx1LinkLocalread-onlycurrentLocal FRM220-GFOM04/08 card fiber1 link state: 0:Link Down 1:Link Up
1.3.6.1.4.1.4756.20.470.20.1.9ColumngfomFx1TypeLocalread-onlycurrentLocal FRM220-GFOM04/08 card fiber1 fiber type: 0:1*9 1:SFP
1.3.6.1.4.1.4756.20.470.20.1.10ColumngfomFx1TxFaultLocalread-onlycurrentLocal FRM220-GFOM04/08 card fiber1 Tx fault: 0:Normal 1:Fault
1.3.6.1.4.1.4756.20.470.20.1.11ColumngfomFx1DDLocalread-onlycurrentLocal FRM220-GFOM04/08 card fiber1 Digital Diagnostic function: 0:No 1:Yes
1.3.6.1.4.1.4756.20.470.20.1.12ColumngfomFx2LinkLocalread-onlycurrentLocal FRM220-GFOM04/08 card fiber2 link state: 0:Link Down 1:Link Up
1.3.6.1.4.1.4756.20.470.20.1.13ColumngfomFx2TypeLocalread-onlycurrentLocal FRM220-GFOM04/08 card fiber2 type: 0:1*9 1:SFP
1.3.6.1.4.1.4756.20.470.20.1.14ColumngfomFx2TxFaultLocalread-onlycurrentLocal FRM220-GFOM04/08 card fiber2 Tx fault: 0:Normal 1:Fault
1.3.6.1.4.1.4756.20.470.20.1.15ColumngfomFx2DDLocalread-onlycurrentLocal FRM220-GFOM04/08 fiber2 Digital Diagnostic function: 0:No 1:Yes
1.3.6.1.4.1.4756.20.470.20.1.16ColumngfomFxWorkingPathLocalread-onlycurrentLocal FRM220-GFOM04/08 card Fx Working Path Status: 0:OP1 1:OP2
1.3.6.1.4.1.4756.20.470.20.1.17ColumngfomFxBitErrorCounterLocalread-onlycurrentLocal FRM220-GFOM04/08 card Fx Bit Error Counter
1.3.6.1.4.1.4756.20.470.20.1.18ColumngfomFxProtectionModeLocalread-writecurrentLocal FRM220-GFOM04/08 card Fx Protection Mode: 0:Auto, Non-Revert 1:Auto, Revert 2:Manual Fx1 3:Manual Fx2
1.3.6.1.4.1.4756.20.470.20.1.19ColumngfomFxALSLocalread-writecurrentLocal FRM220-GFOM04/08 card Fx Auto Laser Shutdown : 0:Disable 1:Enable
1.3.6.1.4.1.4756.20.470.20.1.20ColumngfomFxLoopbackTestLocalread-writecurrentLocal FRM220-GFOM04/08 card Fx Loopback Test: 0:Disable 1:LLB 2:RLB 3:RRLB
1.3.6.1.4.1.4756.20.470.20.1.21ColumngfomFxInserOneErrorBitLocalread-writecurrentLocal FRM220-GFOM04/08 card Fx Bert Insert One Bit Error: 0:Off 1:Action
1.3.6.1.4.1.4756.20.470.20.1.22ColumngfomFxClearBitErrorCounterLocalread-writecurrentLocal FRM220-GFOM04/08 card Fx Clear Bit Error Counter: 0:Off 1:Action
1.3.6.1.4.1.4756.20.470.20.1.23ColumngfomUTPLinkStatusLocalread-onlycurrentLocal FRM220-GFOM04/08 card UTP link state: 0:Link Down 1:Link Up
1.3.6.1.4.1.4756.20.470.20.1.24ColumngfomUTPSpeedStatusLocalread-onlycurrentLocal FRM220-GFOM04/08 card UTP speed state
1.3.6.1.4.1.4756.20.470.20.1.25ColumngfomUTPDuplexStatusLocalread-onlycurrentLocal FRM220-GFOM04/08 card UTP duplex state
1.3.6.1.4.1.4756.20.470.20.1.26ColumngfomUTPPortActiveLocalread-writecurrentLocal FRM220-GFOM04/08 card UTP Port Active : 0:Disable 1:Enable
1.3.6.1.4.1.4756.20.470.20.1.27ColumngfomUTPNegotiationLocalread-writecurrentLocal FRM220-GFOM04/08 card UTP Negotiation : 0:Auto 1:Manual
1.3.6.1.4.1.4756.20.470.20.1.28ColumngfomUTPSpeedConfLocalread-writecurrentLocal FRM220-GFOM04/08 card UTP Speed : 0:10M 1:100M 2:1000M
1.3.6.1.4.1.4756.20.470.20.1.29ColumngfomUTPDuplexConfLocalread-writecurrentLocal FRM220-GFOM04/08 card UTP Duplex : 0:Half 1:Full
1.3.6.1.4.1.4756.20.470.20.1.30ColumngfomUTPFlowControlLocalread-writecurrentLocal FRM220-GFOM04/08 card UTP Flow Control : 0:Disable 1:Enable
1.3.6.1.4.1.4756.20.470.20.1.31ColumngfomUTPJumboFrameLocalread-writecurrentLocal FRM220-GFOM04/08 card UTP Jumbo Frame : 0:Disable 1:Enable
1.3.6.1.4.1.4756.20.470.20.1.32ColumngfomE1T1ModeLocalread-writecurrentLocal FRM220-GFOM04/08 card E1/T1 Mode : 0:E1 (75 ohm) 1:E1 (120 ohm) 2:T1 (100 ohm)
1.3.6.1.4.1.4756.20.470.20.1.33ColumngfomE1T1Channel1LinkStatusLocalread-onlycurrentLocal FRM220-GFOM04/08 card E1/T1 Channel 1 Link Status
1.3.6.1.4.1.4756.20.470.20.1.34ColumngfomE1T1Channel1AISStatusLocalread-onlycurrentLocal FRM220-GFOM04/08 card E1/T1 Channel 1 AIS Status
1.3.6.1.4.1.4756.20.470.20.1.35ColumngfomE1T1Channel1TxDriverFailureLocalread-onlycurrentLocal FRM220-GFOM04/08 card E1/T1 Channel 1 Tx Driver Failure
1.3.6.1.4.1.4756.20.470.20.1.36ColumngfomE1T1Channel1PerformanceLocalread-onlycurrentLocal FRM220-GFOM04/08 card E1/T1 Channel 1 Performance
1.3.6.1.4.1.4756.20.470.20.1.37ColumngfomE1T1Channel1ActiveLocalread-writecurrentLocal FRM220-GFOM04/08 card E1/T1 Channel 1 Active : 0:Disable 1:Enable
1.3.6.1.4.1.4756.20.470.20.1.38ColumngfomE1T1Channel1LinCodeLocalread-writecurrentLocal FRM220-GFOM04/08 card E1/T1 Channel 1 Line Code : 0:HDB3/B8ZS 1:AMI
1.3.6.1.4.1.4756.20.470.20.1.39ColumngfomE1T1Channel1AutoAISLocalread-writecurrentLocal FRM220-GFOM04/08 card E1/T1 Channel 1 Auto AIS : 0:Disable 1:Enable
1.3.6.1.4.1.4756.20.470.20.1.40ColumngfomE1T1Channel1LoopBackLocalread-writecurrentLocal FRM220-GFOM04/08 card E1/T1 Channel 1 Loopback Test : 0:Disable 1:LLB 2:RLB 3:RRLB
1.3.6.1.4.1.4756.20.470.20.1.41ColumngfomE1T1Channel2LinkStatusLocalread-onlycurrentLocal FRM220-GFOM04/08 card E1/T1 Channel 2 Link Status
1.3.6.1.4.1.4756.20.470.20.1.42ColumngfomE1T1Channel2AISStatusLocalread-onlycurrentLocal FRM220-GFOM04/08 card E1/T1 Channel 2 AIS Status
1.3.6.1.4.1.4756.20.470.20.1.43ColumngfomE1T1Channel2TxDriverFailureLocalread-onlycurrentLocal FRM220-GFOM04/08 card E1/T1 Channel 2 Tx Driver Failure
1.3.6.1.4.1.4756.20.470.20.1.44ColumngfomE1T1Channel2PerformanceLocalread-onlycurrentLocal FRM220-GFOM04/08 card E1/T1 Channel 2 Performance
1.3.6.1.4.1.4756.20.470.20.1.45ColumngfomE1T1Channel2ActiveLocalread-writecurrentLocal FRM220-GFOM04/08 card E1/T1 Channel 2 Active : 0:Disable 1:Enable
1.3.6.1.4.1.4756.20.470.20.1.46ColumngfomE1T1Channel2LinCodeLocalread-writecurrentLocal FRM220-GFOM04/08 card E1/T1 Channel 2 Line Code : 0:HDB3/B8ZS 1:AMI
1.3.6.1.4.1.4756.20.470.20.1.47ColumngfomE1T1Channel2AutoAISLocalread-writecurrentLocal FRM220-GFOM04/08 card E1/T1 Channel 2 Auto AIS : 0:Disable 1:Enable
1.3.6.1.4.1.4756.20.470.20.1.48ColumngfomE1T1Channel2LoopBackLocalread-writecurrentLocal FRM220-GFOM04/08 card E1/T1 Channel 2 Loopback Test : 0:Disable 1:LLB 2:RLB 3:RRLB
1.3.6.1.4.1.4756.20.470.20.1.49ColumngfomE1T1Channel3LinkStatusLocalread-onlycurrentLocal FRM220-GFOM04/08 card E1/T1 Channel 3 Link Status
1.3.6.1.4.1.4756.20.470.20.1.50ColumngfomE1T1Channel3AISStatusLocalread-onlycurrentLocal FRM220-GFOM04/08 card E1/T1 Channel 3 AIS Status
1.3.6.1.4.1.4756.20.470.20.1.51ColumngfomE1T1Channel3TxDriverFailureLocalread-onlycurrentLocal FRM220-GFOM04/08 card E1/T1 Channel 3 Tx Driver Failure
1.3.6.1.4.1.4756.20.470.20.1.52ColumngfomE1T1Channel3PerformanceLocalread-onlycurrentLocal FRM220-GFOM04/08 card E1/T1 Channel 3 Performance
1.3.6.1.4.1.4756.20.470.20.1.53ColumngfomE1T1Channel3ActiveLocalread-writecurrentLocal FRM220-GFOM04/08 card E1/T1 Channel 3 Active : 0:Disable 1:Enable
1.3.6.1.4.1.4756.20.470.20.1.54ColumngfomE1T1Channel3LinCodeLocalread-writecurrentLocal FRM220-GFOM04/08 card E1/T1 Channel 3 Line Code : 0:HDB3/B8ZS 1:AMI
1.3.6.1.4.1.4756.20.470.20.1.55ColumngfomE1T1Channel3AutoAISLocalread-writecurrentLocal FRM220-GFOM04/08 card E1/T1 Channel 3 Auto AIS : 0:Disable 1:Enable
1.3.6.1.4.1.4756.20.470.20.1.56ColumngfomE1T1Channel3LoopBackLocalread-writecurrentLocal FRM220-GFOM04/08 card E1/T1 Channel 3 Loopback Test : 0:Disable 1:LLB 2:RLB 3:RRLB
1.3.6.1.4.1.4756.20.470.20.1.57ColumngfomE1T1Channel4LinkStatusLocalread-onlycurrentLocal FRM220-GFOM04/08 card E1/T1 Channel 4 Link Status
1.3.6.1.4.1.4756.20.470.20.1.58ColumngfomE1T1Channel4AISStatusLocalread-onlycurrentLocal FRM220-GFOM04/08 card E1/T1 Channel 4 AIS Status
1.3.6.1.4.1.4756.20.470.20.1.59ColumngfomE1T1Channel4TxDriverFailureLocalread-onlycurrentLocal FRM220-GFOM04/08 card E1/T1 Channel 4 Tx Driver Failure
1.3.6.1.4.1.4756.20.470.20.1.60ColumngfomE1T1Channel4PerformanceLocalread-onlycurrentLocal FRM220-GFOM04/08 card E1/T1 Channel 4 Performance
1.3.6.1.4.1.4756.20.470.20.1.61ColumngfomE1T1Channel4ActiveLocalread-writecurrentLocal FRM220-GFOM04/08 card E1/T1 Channel 4 Active : 0:Disable 1:Enable
1.3.6.1.4.1.4756.20.470.20.1.62ColumngfomE1T1Channel4LinCodeLocalread-writecurrentLocal FRM220-GFOM04/08 card E1/T1 Channel 4 Line Code : 0:HDB3/B8ZS 1:AMI
1.3.6.1.4.1.4756.20.470.20.1.63ColumngfomE1T1Channel4AutoAISLocalread-writecurrentLocal FRM220-GFOM04/08 card E1/T1 Channel 4 Auto AIS : 0:Disable 1:Enable
1.3.6.1.4.1.4756.20.470.20.1.64ColumngfomE1T1Channel4LoopBackLocalread-writecurrentLocal FRM220-GFOM04/08 card E1/T1 Channel 4 Loopback Test : 0:Disable 1:LLB 2:RLB 3:RRLB
1.3.6.1.4.1.4756.20.470.20.1.65ColumngfomE1T1Channel5LinkStatusLocalread-onlycurrentLocal FRM220-GFOM04/08 card E1/T1 Channel 5 Link Status
1.3.6.1.4.1.4756.20.470.20.1.66ColumngfomE1T1Channel5AISStatusLocalread-onlycurrentLocal FRM220-GFOM04/08 card E1/T1 Channel 5 AIS Status
1.3.6.1.4.1.4756.20.470.20.1.67ColumngfomE1T1Channel5TxDriverFailureLocalread-onlycurrentLocal FRM220-GFOM04/08 card E1/T1 Channel 5 Tx Driver Failure
1.3.6.1.4.1.4756.20.470.20.1.68ColumngfomE1T1Channel5PerformanceLocalread-onlycurrentLocal FRM220-GFOM04/08 card E1/T1 Channel 5 Performance
1.3.6.1.4.1.4756.20.470.20.1.69ColumngfomE1T1Channel5ActiveLocalread-writecurrentLocal FRM220-GFOM04/08 card E1/T1 Channel 5 Active : 0:Disable 1:Enable
1.3.6.1.4.1.4756.20.470.20.1.70ColumngfomE1T1Channel5LinCodeLocalread-writecurrentLocal FRM220-GFOM04/08 card E1/T1 Channel 5 Line Code : 0:HDB3/B8ZS 1:AMI
1.3.6.1.4.1.4756.20.470.20.1.71ColumngfomE1T1Channel5AutoAISLocalread-writecurrentLocal FRM220-GFOM04/08 card E1/T1 Channel5 Auto AIS : 0:Disable 1:Enable
1.3.6.1.4.1.4756.20.470.20.1.72ColumngfomE1T1Channel5LoopBackLocalread-writecurrentLocal FRM220-GFOM04/08 card E1/T1 Channel 5 Loopback Test : 0:Disable 1:LLB 2:RLB 3:RRLB
1.3.6.1.4.1.4756.20.470.20.1.73ColumngfomE1T1Channel6LinkStatusLocalread-onlycurrentLocal FRM220-GFOM04/08 card E1/T1 Channel 6 Link Status
1.3.6.1.4.1.4756.20.470.20.1.74ColumngfomE1T1Channel6AISStatusLocalread-onlycurrentLocal FRM220-GFOM04/08 card E1/T1 Channel 6 AIS Status
1.3.6.1.4.1.4756.20.470.20.1.75ColumngfomE1T1Channel6TxDriverFailureLocalread-onlycurrentLocal FRM220-GFOM04/08 card E1/T1 Channel 6 Tx Driver Failure
1.3.6.1.4.1.4756.20.470.20.1.76ColumngfomE1T1Channel6PerformanceLocalread-onlycurrentLocal FRM220-GFOM04/08 card E1/T1 Channel 6 Performance
1.3.6.1.4.1.4756.20.470.20.1.77ColumngfomE1T1Channel6ActiveLocalread-writecurrentLocal FRM220-GFOM04/08 card E1/T1 Channel 6 Active : 0:Disable 1:Enable
1.3.6.1.4.1.4756.20.470.20.1.78ColumngfomE1T1Channel6LinCodeLocalread-writecurrentLocal FRM220-GFOM04/08 card E1/T1 Channel 6 Line Code : 0:HDB3/B8ZS 1:AMI
1.3.6.1.4.1.4756.20.470.20.1.79ColumngfomE1T1Channel6AutoAISLocalread-writecurrentLocal FRM220-GFOM04/08 card E1/T1 Channel 6 Auto AIS : 0:Disable 1:Enable
1.3.6.1.4.1.4756.20.470.20.1.80ColumngfomE1T1Channel6LoopBackLocalread-writecurrentLocal FRM220-GFOM04/08 card E1/T1 Channel 6 Loopback Test : 0:Disable 1:LLB 2:RLB 3:RRLB
1.3.6.1.4.1.4756.20.470.20.1.81ColumngfomE1T1Channel7LinkStatusLocalread-onlycurrentLocal FRM220-GFOM04/08 card E1/T1 Channel 7 Link Status
1.3.6.1.4.1.4756.20.470.20.1.82ColumngfomE1T1Channel7AISStatusLocalread-onlycurrentLocal FRM220-GFOM04/08 card E1/T1 Channel 7 AIS Status
1.3.6.1.4.1.4756.20.470.20.1.83ColumngfomE1T1Channel7TxDriverFailureLocalread-onlycurrentLocal FRM220-GFOM04/08 card E1/T1 Channel 7 Tx Driver Failure
1.3.6.1.4.1.4756.20.470.20.1.84ColumngfomE1T1Channel7PerformanceLocalread-onlycurrentLocal FRM220-GFOM04/08 card E1/T1 Channel 7 Performance
1.3.6.1.4.1.4756.20.470.20.1.85ColumngfomE1T1Channel7ActiveLocalread-writecurrentLocal FRM220-GFOM04/08 card E1/T1 Channel 7 Active : 0:Disable 1:Enable
1.3.6.1.4.1.4756.20.470.20.1.86ColumngfomE1T1Channel7LinCodeLocalread-writecurrentLocal FRM220-GFOM04/08 card E1/T1 Channel 7 Line Code : 0:HDB3/B8ZS 1:AMI
1.3.6.1.4.1.4756.20.470.20.1.87ColumngfomE1T1Channel7AutoAISLocalread-writecurrentLocal FRM220-GFOM04/08 card E1/T1 Channel 7 Auto AIS : 0:Disable 1:Enable
1.3.6.1.4.1.4756.20.470.20.1.88ColumngfomE1T1Channel7LoopBackLocalread-writecurrentLocal FRM220-GFOM04/08 card E1/T1 Channel 7 Loopback Test : 0:Disable 1:LLB 2:RLB 3:RRLB
1.3.6.1.4.1.4756.20.470.20.1.89ColumngfomE1T1Channel8LinkStatusLocalread-onlycurrentLocal FRM220-GFOM04/08 card E1/T1 Channel 8 Link Status
1.3.6.1.4.1.4756.20.470.20.1.90ColumngfomE1T1Channel8AISStatusLocalread-onlycurrentLocal FRM220-GFOM04/08 card E1/T1 Channel 8 AIS Status
1.3.6.1.4.1.4756.20.470.20.1.91ColumngfomE1T1Channel8TxDriverFailureLocalread-onlycurrentLocal FRM220-GFOM04/08 card E1/T1 Channel 8 Tx Driver Failure
1.3.6.1.4.1.4756.20.470.20.1.92ColumngfomE1T1Channel8PerformanceLocalread-onlycurrentLocal FRM220-GFOM04/08 card E1/T1 Channel 8 Performance
1.3.6.1.4.1.4756.20.470.20.1.93ColumngfomE1T1Channel8ActiveLocalread-writecurrentLocal FRM220-GFOM04/08 card E1/T1 Channel 8 Active : 0:Disable 1:Enable
1.3.6.1.4.1.4756.20.470.20.1.94ColumngfomE1T1Channel8LinCodeLocalread-writecurrentLocal FRM220-GFOM04/08 card E1/T1 Channel 8 Line Code : 0:HDB3/B8ZS 1:AMI
1.3.6.1.4.1.4756.20.470.20.1.95ColumngfomE1T1Channel8AutoAISLocalread-writecurrentLocal FRM220-GFOM04/08 card E1/T1 Channel 8 Auto AIS : 0:Disable 1:Enable
1.3.6.1.4.1.4756.20.470.20.1.96ColumngfomE1T1Channel8LoopBackLocalread-writecurrentLocal FRM220-GFOM04/08 card E1/T1 Channel 8 Loopback Test : 0:Disable 1:LLB 2:RLB 3:RRLB
1.3.6.1.4.1.4756.20.470.20.1.97ColumngfomE1T1ClearPerformanceCounterLocalread-writecurrentLocal FRM220-GFOM04/08 card E1/T1 Clear Performance Counter GFOM04:1-4 GFOM08:1-8
1.3.6.1.4.1.4756.20.470.20.1.98ColumngfomOrderWirePhoneRingLocalread-onlycurrentLocal FRM220-GFOM04/08 card Order Wire Phone Ring : 0:None 1:Ring
1.3.6.1.4.1.4756.20.470.20.1.99ColumngfomOrderWireTypeLocalread-onlycurrentLocal FRM220-GFOM04/08 card Order Wire Type : 1:2-Wire 2:4-Wire 3:Empty
1.3.6.1.4.1.4756.20.470.20.1.100ColumngfomOrderWireActiveLocalread-writecurrentLocal FRM220-GFOM04/08 card Order Wire Active : 0:Disable 1:Enable
1.3.6.1.4.1.4756.20.470.20.1.101ColumngfomAlarmStatusLocalread-onlycurrentLocal FRM220-GFOM04/08 card Alarm Status : 0:None 1:Alarm
1.3.6.1.4.1.4756.20.470.20.1.102ColumngfomAlarmBuzzerStatusLocalread-onlycurrentLocal FRM220-GFOM04/08 card Alarm Buzzer Status : 0:Normal 1:Buzzer
1.3.6.1.4.1.4756.20.470.20.1.103ColumngfomAlarmRDIStatusLocalread-onlycurrentLocal FRM220-GFOM04/08 card Alarm RDI Status : 0:None 1:Remote Alarm
1.3.6.1.4.1.4756.20.470.20.1.104ColumngfomAlarmBuzzerLocalread-writecurrentLocal FRM220-GFOM04/08 card Alarm Buzzer Active: 0:Disable 1:Enable
1.3.6.1.4.1.4756.20.470.20.1.105ColumngfomAlarmTriggerOpticalLocalread-writecurrentLocal FRM220-GFOM04/08 card Alarm Trigger Optical: 0:No 1:Yes
1.3.6.1.4.1.4756.20.470.20.1.106ColumngfomAlarmTriggerLANLocalread-writecurrentLocal FRM220-GFOM04/08 card Alarm Trigger LAN: 0:No 1:Yes
1.3.6.1.4.1.4756.20.470.20.1.107ColumngfomAlarmTriggerRDILocalread-writecurrentLocal FRM220-GFOM04/08 card Alarm Trigger RDI: 0:No 1:Yes
1.3.6.1.4.1.4756.20.470.20.1.108ColumngfomDeviceActiveLocalread-writecurrentLocal FRM220-GFOM04/08 card Device Active: 0:Disable 1:Enable
1.3.6.1.4.1.4756.20.470.20.1.109ColumngfomSetDefaultLocalread-writecurrentForce remote FRM220-GFOM04/08 card to default : 0:Off 1:Action
1.3.6.1.4.1.4756.20.470.20.1.110ColumngfomPortResetLocalread-writecurrentForce remote FRM220-GFOM04/08 card reset mode: 0:Off 1:Action
1.3.6.1.4.1.4756.20.470.20.1.111ColumngfomFx1DDVendorLocalread-onlycurrentLocal FRM220-GFOM04/08 card fiber1 D/D information: Vendor name
1.3.6.1.4.1.4756.20.470.20.1.112ColumngfomFx1DDPartNoLocalread-onlycurrentLocal FRM220-GFOM04/08 card fiber1 D/D information: Vendor part number
1.3.6.1.4.1.4756.20.470.20.1.113ColumngfomFx1DDFiberTypeLocalread-onlycurrentLocal FRM220-GFOM04/08 card fiber1 D/D information: Fiber Type
1.3.6.1.4.1.4756.20.470.20.1.114ColumngfomFx1DDWaveLenLocalread-onlycurrentLocal FRM220-GFOM04/08 card fiber1 D/D information: Wave length
1.3.6.1.4.1.4756.20.470.20.1.115ColumngfomFx1DDWaveLen2Localread-onlycurrentLocal FRM220-GFOM04/08 card fiber1 D/D information: Wave length 2
1.3.6.1.4.1.4756.20.470.20.1.116ColumngfomFx1DDLinkLenLocalread-onlycurrentLocal FRM220-GFOM04/08 card fiber1 D/D information: Link length
1.3.6.1.4.1.4756.20.470.20.1.117ColumngfomFx1DDLenUnitLocalread-onlycurrentLocal FRM220-GFOM04/08 card fiber1 D/D information: Length Unit
1.3.6.1.4.1.4756.20.470.20.1.118ColumngfomFx1DDStatusLocalread-onlycurrentLocal FRM220-GFOM04/08 card fiber1 D/D information: Status Support
1.3.6.1.4.1.4756.20.470.20.1.119ColumngfomFx1DDRxSensLocalread-onlycurrentLocal FRM220-GFOM04/08 card fiber1 D/D information: Rx Sensitivity
1.3.6.1.4.1.4756.20.470.20.1.120ColumngfomFx1DDTxPwrLocalread-onlycurrentLocal FRM220-GFOM04/08 card fiber1 D/D information: Tx power
1.3.6.1.4.1.4756.20.470.20.1.121ColumngfomFx1DDRxPwrLocalread-onlycurrentLocal FRM220-GFOM04/08 card fiber1 D/D information: Rx power
1.3.6.1.4.1.4756.20.470.20.1.122ColumngfomFx1DDTempLocalread-onlycurrentLocal FRM220-GFOM04/08 card fiber1 D/D information: Temperature in degree C
1.3.6.1.4.1.4756.20.470.20.1.123ColumngfomFx1DDPwrMarginLocalread-onlycurrentLocal FRM220-GFOM04/08 card fiber1 D/D information: Power margin
1.3.6.1.4.1.4756.20.470.20.1.124ColumngfomFx2DDVendorLocalread-onlycurrentLocal FRM220-GFOM04/08 card fiber2 D/D information: Vendor name
1.3.6.1.4.1.4756.20.470.20.1.125ColumngfomFx2DDPartNoLocalread-onlycurrentLocal FRM220-GFOM04/08 card fiber2 D/D information: Vendor part number
1.3.6.1.4.1.4756.20.470.20.1.126ColumngfomFx2DDFiberTypeLocalread-onlycurrentLocal FRM220-GFOM04/08 card fiber2 D/D information: Fiber Type
1.3.6.1.4.1.4756.20.470.20.1.127ColumngfomFx2DDWaveLenLocalread-onlycurrentLocal FRM220-GFOM04/08 card fiber2 D/D information: Wave length
1.3.6.1.4.1.4756.20.470.20.1.128ColumngfomFx2DDWaveLen2Localread-onlycurrentLocal FRM220-GFOM04/08 card fiber2 D/D information: Wave length 2
1.3.6.1.4.1.4756.20.470.20.1.129ColumngfomFx2DDLinkLenLocalread-onlycurrentLocal FRM220-GFOM04/08 card fiber2 D/D information: Link length
1.3.6.1.4.1.4756.20.470.20.1.130ColumngfomFx2DDLenUnitLocalread-onlycurrentLocal FRM220-GFOM04/08 card fiber2 D/D information: Length Unit
1.3.6.1.4.1.4756.20.470.20.1.131ColumngfomFx2DDStatusLocalread-onlycurrentLocal FRM220-GFOM04/08 card fiber2 D/D information: Status Support
1.3.6.1.4.1.4756.20.470.20.1.132ColumngfomFx2DDRxSensLocalread-onlycurrentLocal FRM220-GFOM04/08 card fiber2 D/D information: Rx Sensitivity
1.3.6.1.4.1.4756.20.470.20.1.133ColumngfomFx2DDTxPwrLocalread-onlycurrentLocal FRM220-GFOM04/08 card fiber2 D/D information: Tx power
1.3.6.1.4.1.4756.20.470.20.1.134ColumngfomFx2DDRxPwrLocalread-onlycurrentLocal FRM220-GFOM04/08 card fiber2 D/D information: Rx power
1.3.6.1.4.1.4756.20.470.20.1.135ColumngfomFx2DDTempLocalread-onlycurrentLocal FRM220-GFOM04/08 card fiber2 D/D information: Temperature in degree C
1.3.6.1.4.1.4756.20.470.20.1.136ColumngfomFx2DDPwrMarginLocalread-onlycurrentLocal FRM220-GFOM04/08 card fiber2 D/D information: Power margin
1.3.6.1.4.1.4756.20.470.20.1.137ColumngfomRemotePowerLocalread-onlycurrentLocal FRM220-GFOM04 Remote power fail: 0:Ok 1:Abnormal
1.3.6.1.4.1.4756.20.470.20.1.138ColumngfomFEFLocalread-onlycurrentLocal FRM220-GFOM04 FEF: 0:Off 1:Detected
1.3.6.1.4.1.4756.20.471NodegfomRemoteCards
1.3.6.1.4.1.4756.20.471.20TablegfomRemoteTablenot-accessiblecurrentA list of Remote FRM220-GFOM04/08 card entries.
1.3.6.1.4.1.4756.20.471.20.1RowgfomRemoteEntrynot-accessiblecurrentAn entry containing management information applicable to a particular Remote FRM220-GFOM04/08 card.
1.3.6.1.4.1.4756.20.471.20.1.1ColumngfomChassisIndexRemoteread-onlycurrentA unique value for each Remote card. It is the chassis location number.
1.3.6.1.4.1.4756.20.471.20.1.2ColumngfomSlotIndexRemoteread-onlycurrentA unique value for each Remote card. It is the slot location number.
1.3.6.1.4.1.4756.20.471.20.1.3ColumngfomCardHWVerRemoteread-onlycurrentRemote FRM220-GFOM04/08 card hardware version x.xxx
1.3.6.1.4.1.4756.20.471.20.1.4ColumngfomCardFWVerRemoteread-onlycurrentRemote FRM220-GFOM04/08 card firmware version x.xxx
1.3.6.1.4.1.4756.20.471.20.1.5ColumngfomCardCPLDVerRemoteread-onlycurrentRemote FRM220-GFOM04/08 card CPLD version x.xxx
1.3.6.1.4.1.4756.20.471.20.1.6ColumngfomCardFPGAVerRemoteread-onlycurrentRemote FRM220-GFOM04/08 card FPGA version x.xxx
1.3.6.1.4.1.4756.20.471.20.1.7ColumngfomModelRemoteread-onlycurrentRemote FRM220-GFOM04/08 Mode: 0:FRM220-GFOM04 1:FRM220-GFOM08 2:FMUX800
1.3.6.1.4.1.4756.20.471.20.1.8ColumngfomFx1LinkRemoteread-onlycurrentRemote FRM220-GFOM04/08 card fiber1 link state: 0:Link Down 1:Link Up
1.3.6.1.4.1.4756.20.471.20.1.9ColumngfomFx1TypeRemoteread-onlycurrentRemote FRM220-GFOM04/08 card fiber1 fiber type: 0:1*9 1:SFP
1.3.6.1.4.1.4756.20.471.20.1.10ColumngfomFx1TxFaultRemoteread-onlycurrentRemote FRM220-GFOM04/08 card fiber1 Tx fault: 0:Normal 1:Fault
1.3.6.1.4.1.4756.20.471.20.1.11ColumngfomFx1DDRemoteread-onlycurrentRemote FRM220-GFOM04/08 card fiber1 Digital Diagnostic function: 0:No 1:Yes
1.3.6.1.4.1.4756.20.471.20.1.12ColumngfomFx2LinkRemoteread-onlycurrentRemote FRM220-GFOM04/08 card fiber2 link state: 0:Link Down 1:Link Up
1.3.6.1.4.1.4756.20.471.20.1.13ColumngfomFx2TypeRemoteread-onlycurrentRemote FRM220-GFOM04/08 card fiber2 type: 0:1*9 1:SFP
1.3.6.1.4.1.4756.20.471.20.1.14ColumngfomFx2TxFaultRemoteread-onlycurrentRemote FRM220-GFOM04/08 card fiber2 Tx fault: 0:Normal 1:Fault
1.3.6.1.4.1.4756.20.471.20.1.15ColumngfomFx2DDRemoteread-onlycurrentRemote FRM220-GFOM04/08 fiber2 Digital Diagnostic function: 0:No 1:Yes
1.3.6.1.4.1.4756.20.471.20.1.16ColumngfomFxWorkingPathRemoteread-onlycurrentRemote FRM220-GFOM04/08 card Fx Working Path Status: 0:OP1 1:OP2
1.3.6.1.4.1.4756.20.471.20.1.17ColumngfomFxBitErrorCounterRemoteread-onlycurrentRemote FRM220-GFOM04/08 card Fx Bit Error Counter
1.3.6.1.4.1.4756.20.471.20.1.18ColumngfomFxProtectionModeRemoteread-writecurrentRemote FRM220-GFOM04/08 card Fx Protection Mode: 0:Auto, Non-Revert 1:Auto, Revert 2:Manual Fx1 3:Manual Fx2
1.3.6.1.4.1.4756.20.471.20.1.19ColumngfomFxALSRemoteread-writecurrentRemote FRM220-GFOM04/08 card Fx Auto Laser Shutdown : 0:Disable 1:Enable
1.3.6.1.4.1.4756.20.471.20.1.20ColumngfomFxLoopbackTestRemoteread-onlycurrentRemote FRM220-GFOM04/08 card Fx Loopback Test: 0:Disable
1.3.6.1.4.1.4756.20.471.20.1.21ColumngfomFxInserOneErrorBitRemoteread-writecurrentRemote FRM220-GFOM04/08 card Fx Bert Insert One Bit Error: 0:Off 1:Action
1.3.6.1.4.1.4756.20.471.20.1.22ColumngfomFxClearBitErrorCounterRemoteread-writecurrentRemote FRM220-GFOM04/08 card Fx Clear Bit Error Counter: 0:Off 1:Action
1.3.6.1.4.1.4756.20.471.20.1.23ColumngfomUTPLinkStatusRemoteread-onlycurrentRemote FRM220-GFOM04/08 card UTP link state: 0:Link Down 1:Link Up
1.3.6.1.4.1.4756.20.471.20.1.24ColumngfomUTPSpeedStatusRemoteread-onlycurrentRemote FRM220-GFOM04/08 card UTP speed state
1.3.6.1.4.1.4756.20.471.20.1.25ColumngfomUTPDuplexStatusRemoteread-onlycurrentRemote FRM220-GFOM04/08 card UTP duplex state
1.3.6.1.4.1.4756.20.471.20.1.26ColumngfomUTPPortActiveRemoteread-writecurrentRemote FRM220-GFOM04/08 card UTP Port Active : 0:Disable 1:Enable
1.3.6.1.4.1.4756.20.471.20.1.27ColumngfomUTPNegotiationRemoteread-writecurrentRemote FRM220-GFOM04/08 card UTP Negotiation : 0:Auto 1:Manual
1.3.6.1.4.1.4756.20.471.20.1.28ColumngfomUTPSpeedConfRemoteread-writecurrentRemote FRM220-GFOM04/08 card UTP Speed : 0:10M 1:100M 2:1000M
1.3.6.1.4.1.4756.20.471.20.1.29ColumngfomUTPDuplexConfRemoteread-writecurrentRemote FRM220-GFOM04/08 card UTP Duplex : 0:Half 1:Full
1.3.6.1.4.1.4756.20.471.20.1.30ColumngfomUTPFlowControlRemoteread-writecurrentRemote FRM220-GFOM04/08 card UTP Flow Control : 0:Disable 1:Enable
1.3.6.1.4.1.4756.20.471.20.1.31ColumngfomUTPJumboFrameRemoteread-writecurrentRemote FRM220-GFOM04/08 card UTP Jumbo Frame : 0:Disable 1:Enable
1.3.6.1.4.1.4756.20.471.20.1.32ColumngfomE1T1ModeRemoteread-writecurrentRemote FRM220-GFOM04/08 card E1/T1 Mode : 0:E1 (75 ohm) 1:E1 (120 ohm) 2:T1 (100 ohm)
1.3.6.1.4.1.4756.20.471.20.1.33ColumngfomE1T1Channel1LinkStatusRemoteread-onlycurrentRemote FRM220-GFOM04/08 card E1/T1 Channel 1 Link Status
1.3.6.1.4.1.4756.20.471.20.1.34ColumngfomE1T1Channel1AISStatusRemoteread-onlycurrentRemote FRM220-GFOM04/08 card E1/T1 Channel 1 AIS Status
1.3.6.1.4.1.4756.20.471.20.1.35ColumngfomE1T1Channel1TxDriverFailureRemoteread-onlycurrentRemote FRM220-GFOM04/08 card E1/T1 Channel 1 Tx Driver Failure
1.3.6.1.4.1.4756.20.471.20.1.36ColumngfomE1T1Channel1PerformanceRemoteread-onlycurrentRemote FRM220-GFOM04/08 card E1/T1 Channel 1 Performance
1.3.6.1.4.1.4756.20.471.20.1.37ColumngfomE1T1Channel1ActiveRemoteread-writecurrentRemote FRM220-GFOM04/08 card E1/T1 Channel 1 Active : 0:Disable 1:Enable
1.3.6.1.4.1.4756.20.471.20.1.38ColumngfomE1T1Channel1LinCodeRemoteread-writecurrentRemote FRM220-GFOM04/08 card E1/T1 Channel 1 Line Code : 0:HDB3/B8ZS 1:AMI
1.3.6.1.4.1.4756.20.471.20.1.39ColumngfomE1T1Channel1AutoAISRemoteread-writecurrentRemote FRM220-GFOM04/08 card E1/T1 Channel 1 Auto AIS : 0:Disable 1:Enable
1.3.6.1.4.1.4756.20.471.20.1.40ColumngfomE1T1Channel1LoopBackRemoteread-writecurrentRemote FRM220-GFOM04/08 card E1/T1 Channel 1 Loopback Test : 0:Disable 1:LLB 2:RLB 3:RRLB
1.3.6.1.4.1.4756.20.471.20.1.41ColumngfomE1T1Channel2LinkStatusRemoteread-onlycurrentRemote FRM220-GFOM04/08 card E1/T1 Channel 2 Link Status
1.3.6.1.4.1.4756.20.471.20.1.42ColumngfomE1T1Channel2AISStatusRemoteread-onlycurrentRemote FRM220-GFOM04/08 card E1/T1 Channel 2 AIS Status
1.3.6.1.4.1.4756.20.471.20.1.43ColumngfomE1T1Channel2TxDriverFailureRemoteread-onlycurrentRemote FRM220-GFOM04/08 card E1/T1 Channel 2 Tx Driver Failure
1.3.6.1.4.1.4756.20.471.20.1.44ColumngfomE1T1Channel2PerformanceRemoteread-onlycurrentRemote FRM220-GFOM04/08 card E1/T1 Channel 2 Performance
1.3.6.1.4.1.4756.20.471.20.1.45ColumngfomE1T1Channel2ActiveRemoteread-writecurrentRemote FRM220-GFOM04/08 card E1/T1 Channel 2 Active : 0:Disable 1:Enable
1.3.6.1.4.1.4756.20.471.20.1.46ColumngfomE1T1Channel2LinCodeRemoteread-writecurrentRemote FRM220-GFOM04/08 card E1/T1 Channel 2 Line Code : 0:HDB3/B8ZS 1:AMI
1.3.6.1.4.1.4756.20.471.20.1.47ColumngfomE1T1Channel2AutoAISRemoteread-writecurrentRemote FRM220-GFOM04/08 card E1/T1 Channel 2 Auto AIS : 0:Disable 1:Enable
1.3.6.1.4.1.4756.20.471.20.1.48ColumngfomE1T1Channel2LoopBackRemoteread-writecurrentRemote FRM220-GFOM04/08 card E1/T1 Channel 2 Loopback Test : 0:Disable 1:LLB 2:RLB 3:RRLB
1.3.6.1.4.1.4756.20.471.20.1.49ColumngfomE1T1Channel3LinkStatusRemoteread-onlycurrentRemote FRM220-GFOM04/08 card E1/T1 Channel 3 Link Status
1.3.6.1.4.1.4756.20.471.20.1.50ColumngfomE1T1Channel3AISStatusRemoteread-onlycurrentRemote FRM220-GFOM04/08 card E1/T1 Channel 3 AIS Status
1.3.6.1.4.1.4756.20.471.20.1.51ColumngfomE1T1Channel3TxDriverFailureRemoteread-onlycurrentRemote FRM220-GFOM04/08 card E1/T1 Channel 3 Tx Driver Failure
1.3.6.1.4.1.4756.20.471.20.1.52ColumngfomE1T1Channel3PerformanceRemoteread-onlycurrentRemote FRM220-GFOM04/08 card E1/T1 Channel 3 Performance
1.3.6.1.4.1.4756.20.471.20.1.53ColumngfomE1T1Channel3ActiveRemoteread-writecurrentRemote FRM220-GFOM04/08 card E1/T1 Channel 3 Active : 0:Disable 1:Enable
1.3.6.1.4.1.4756.20.471.20.1.54ColumngfomE1T1Channel3LinCodeRemoteread-writecurrentRemote FRM220-GFOM04/08 card E1/T1 Channel 3 Line Code : 0:HDB3/B8ZS 1:AMI
1.3.6.1.4.1.4756.20.471.20.1.55ColumngfomE1T1Channel3AutoAISRemoteread-writecurrentRemote FRM220-GFOM04/08 card E1/T1 Channel 3 Auto AIS : 0:Disable 1:Enable
1.3.6.1.4.1.4756.20.471.20.1.56ColumngfomE1T1Channel3LoopBackRemoteread-writecurrentRemote FRM220-GFOM04/08 card E1/T1 Channel 3 Loopback Test : 0:Disable 1:LLB 2:RLB 3:RRLB
1.3.6.1.4.1.4756.20.471.20.1.57ColumngfomE1T1Channel4LinkStatusRemoteread-onlycurrentRemote FRM220-GFOM04/08 card E1/T1 Channel 4 Link Status
1.3.6.1.4.1.4756.20.471.20.1.58ColumngfomE1T1Channel4AISStatusRemoteread-onlycurrentRemote FRM220-GFOM04/08 card E1/T1 Channel 4 AIS Status
1.3.6.1.4.1.4756.20.471.20.1.59ColumngfomE1T1Channel4TxDriverFailureRemoteread-onlycurrentRemote FRM220-GFOM04/08 card E1/T1 Channel 4 Tx Driver Failure
1.3.6.1.4.1.4756.20.471.20.1.60ColumngfomE1T1Channel4PerformanceRemoteread-onlycurrentRemote FRM220-GFOM04/08 card E1/T1 Channel 4 Performance
1.3.6.1.4.1.4756.20.471.20.1.61ColumngfomE1T1Channel4ActiveRemoteread-writecurrentRemote FRM220-GFOM04/08 card E1/T1 Channel 4 Active : 0:Disable 1:Enable
1.3.6.1.4.1.4756.20.471.20.1.62ColumngfomE1T1Channel4LinCodeRemoteread-writecurrentRemote FRM220-GFOM04/08 card E1/T1 Channel 4 Line Code : 0:HDB3/B8ZS 1:AMI
1.3.6.1.4.1.4756.20.471.20.1.63ColumngfomE1T1Channel4AutoAISRemoteread-writecurrentRemote FRM220-GFOM04/08 card E1/T1 Channel 4 Auto AIS : 0:Disable 1:Enable
1.3.6.1.4.1.4756.20.471.20.1.64ColumngfomE1T1Channel4LoopBackRemoteread-writecurrentRemote FRM220-GFOM04/08 card E1/T1 Channel 4 Loopback Test : 0:Disable 1:LLB 2:RLB 3:RRLB
1.3.6.1.4.1.4756.20.471.20.1.65ColumngfomE1T1Channel5LinkStatusRemoteread-onlycurrentRemote FRM220-GFOM04/08 card E1/T1 Channel 5 Link Status
1.3.6.1.4.1.4756.20.471.20.1.66ColumngfomE1T1Channel5AISStatusRemoteread-onlycurrentRemote FRM220-GFOM04/08 card E1/T1 Channel 5 AIS Status
1.3.6.1.4.1.4756.20.471.20.1.67ColumngfomE1T1Channel5TxDriverFailureRemoteread-onlycurrentRemote FRM220-GFOM04/08 card E1/T1 Channel 5 Tx Driver Failure
1.3.6.1.4.1.4756.20.471.20.1.68ColumngfomE1T1Channel5PerformanceRemoteread-onlycurrentRemote FRM220-GFOM04/08 card E1/T1 Channel 5 Performance
1.3.6.1.4.1.4756.20.471.20.1.69ColumngfomE1T1Channel5ActiveRemoteread-writecurrentRemote FRM220-GFOM04/08 card E1/T1 Channel 5 Active : 0:Disable 1:Enable
1.3.6.1.4.1.4756.20.471.20.1.70ColumngfomE1T1Channel5LinCodeRemoteread-writecurrentRemote FRM220-GFOM04/08 card E1/T1 Channel 5 Line Code : 0:HDB3/B8ZS 1:AMI
1.3.6.1.4.1.4756.20.471.20.1.71ColumngfomE1T1Channel5AutoAISRemoteread-writecurrentRemote FRM220-GFOM04/08 card E1/T1 Channel5 Auto AIS : 0:Disable 1:Enable
1.3.6.1.4.1.4756.20.471.20.1.72ColumngfomE1T1Channel5LoopBackRemoteread-writecurrentRemote FRM220-GFOM04/08 card E1/T1 Channel 5 Loopback Test : 0:Disable 1:LLB 2:RLB 3:RRLB
1.3.6.1.4.1.4756.20.471.20.1.73ColumngfomE1T1Channel6LinkStatusRemoteread-onlycurrentRemote FRM220-GFOM04/08 card E1/T1 Channel 6 Link Status
1.3.6.1.4.1.4756.20.471.20.1.74ColumngfomE1T1Channel6AISStatusRemoteread-onlycurrentRemote FRM220-GFOM04/08 card E1/T1 Channel 6 AIS Status
1.3.6.1.4.1.4756.20.471.20.1.75ColumngfomE1T1Channel6TxDriverFailureRemoteread-onlycurrentRemote FRM220-GFOM04/08 card E1/T1 Channel 6 Tx Driver Failure
1.3.6.1.4.1.4756.20.471.20.1.76ColumngfomE1T1Channel6PerformanceRemoteread-onlycurrentRemote FRM220-GFOM04/08 card E1/T1 Channel 6 Performance
1.3.6.1.4.1.4756.20.471.20.1.77ColumngfomE1T1Channel6ActiveRemoteread-writecurrentRemote FRM220-GFOM04/08 card E1/T1 Channel 6 Active : 0:Disable 1:Enable
1.3.6.1.4.1.4756.20.471.20.1.78ColumngfomE1T1Channel6LinCodeRemoteread-writecurrentRemote FRM220-GFOM04/08 card E1/T1 Channel 6 Line Code : 0:HDB3/B8ZS 1:AMI
1.3.6.1.4.1.4756.20.471.20.1.79ColumngfomE1T1Channel6AutoAISRemoteread-writecurrentRemote FRM220-GFOM04/08 card E1/T1 Channel 6 Auto AIS : 0:Disable 1:Enable
1.3.6.1.4.1.4756.20.471.20.1.80ColumngfomE1T1Channel6LoopBackRemoteread-writecurrentRemote FRM220-GFOM04/08 card E1/T1 Channel 6 Loopback Test : 0:Disable 1:LLB 2:RLB 3:RRLB
1.3.6.1.4.1.4756.20.471.20.1.81ColumngfomE1T1Channel7LinkStatusRemoteread-onlycurrentRemote FRM220-GFOM04/08 card E1/T1 Channel 7 Link Status
1.3.6.1.4.1.4756.20.471.20.1.82ColumngfomE1T1Channel7AISStatusRemoteread-onlycurrentRemote FRM220-GFOM04/08 card E1/T1 Channel 7 AIS Status
1.3.6.1.4.1.4756.20.471.20.1.83ColumngfomE1T1Channel7TxDriverFailureRemoteread-onlycurrentRemote FRM220-GFOM04/08 card E1/T1 Channel 7 Tx Driver Failure
1.3.6.1.4.1.4756.20.471.20.1.84ColumngfomE1T1Channel7PerformanceRemoteread-onlycurrentRemote FRM220-GFOM04/08 card E1/T1 Channel 7 Performance
1.3.6.1.4.1.4756.20.471.20.1.85ColumngfomE1T1Channel7ActiveRemoteread-writecurrentRemote FRM220-GFOM04/08 card E1/T1 Channel 7 Active : 0:Disable 1:Enable
1.3.6.1.4.1.4756.20.471.20.1.86ColumngfomE1T1Channel7LinCodeRemoteread-writecurrentRemote FRM220-GFOM04/08 card E1/T1 Channel 7 Line Code : 0:HDB3/B8ZS 1:AMI
1.3.6.1.4.1.4756.20.471.20.1.87ColumngfomE1T1Channel7AutoAISRemoteread-writecurrentRemote FRM220-GFOM04/08 card E1/T1 Channel 7 Auto AIS : 0:Disable 1:Enable
1.3.6.1.4.1.4756.20.471.20.1.88ColumngfomE1T1Channel7LoopBackRemoteread-writecurrentRemote FRM220-GFOM04/08 card E1/T1 Channel 7 Loopback Test : 0:Disable 1:LLB 2:RLB 3:RRLB
1.3.6.1.4.1.4756.20.471.20.1.89ColumngfomE1T1Channel8LinkStatusRemoteread-onlycurrentRemote FRM220-GFOM04/08 card E1/T1 Channel 8 Link Status
1.3.6.1.4.1.4756.20.471.20.1.90ColumngfomE1T1Channel8AISStatusRemoteread-onlycurrentRemote FRM220-GFOM04/08 card E1/T1 Channel 8 AIS Status
1.3.6.1.4.1.4756.20.471.20.1.91ColumngfomE1T1Channel8TxDriverFailureRemoteread-onlycurrentRemote FRM220-GFOM04/08 card E1/T1 Channel 8 Tx Driver Failure
1.3.6.1.4.1.4756.20.471.20.1.92ColumngfomE1T1Channel8PerformanceRemoteread-onlycurrentRemote FRM220-GFOM04/08 card E1/T1 Channel 8 Performance
1.3.6.1.4.1.4756.20.471.20.1.93ColumngfomE1T1Channel8ActiveRemoteread-writecurrentRemote FRM220-GFOM04/08 card E1/T1 Channel 8 Active : 0:Disable 1:Enable
1.3.6.1.4.1.4756.20.471.20.1.94ColumngfomE1T1Channel8LinCodeRemoteread-writecurrentRemote FRM220-GFOM04/08 card E1/T1 Channel 8 Line Code : 0:HDB3/B8ZS 1:AMI
1.3.6.1.4.1.4756.20.471.20.1.95ColumngfomE1T1Channel8AutoAISRemoteread-writecurrentRemote FRM220-GFOM04/08 card E1/T1 Channel 8 Auto AIS : 0:Disable 1:Enable
1.3.6.1.4.1.4756.20.471.20.1.96ColumngfomE1T1Channel8LoopBackRemoteread-writecurrentRemote FRM220-GFOM04/08 card E1/T1 Channel 8 Loopback Test : 0:Disable 1:LLB 2:RLB 3:RRLB
1.3.6.1.4.1.4756.20.471.20.1.97ColumngfomE1T1ClearPerformanceCounterRemoteread-writecurrentRemote FRM220-GFOM04/08 card E1/T1 Clear Performance Counter GFOM04:1-4 GFOM08:1-8
1.3.6.1.4.1.4756.20.471.20.1.98ColumngfomOrderWirePhoneRingRemoteread-onlycurrentRemote FRM220-GFOM04/08 card Order Wire Phone Ring : 0:None 1:Ring
1.3.6.1.4.1.4756.20.471.20.1.99ColumngfomOrderWireTypeRemoteread-onlycurrentRemote FRM220-GFOM04/08 card Order Wire Type : 1:2-Wire 2:4-Wire 3:Empty
1.3.6.1.4.1.4756.20.471.20.1.100ColumngfomOrderWireActiveRemoteread-writecurrentRemote FRM220-GFOM04/08 card Order Wire Active : 0:Disable 1:Enable
1.3.6.1.4.1.4756.20.471.20.1.101ColumngfomAlarmStatusRemoteread-onlycurrentRemote FRM220-GFOM04/08 card Alarm Status : 0:None 1:Alarm
1.3.6.1.4.1.4756.20.471.20.1.102ColumngfomAlarmBuzzerStatusRemoteread-onlycurrentRemote FRM220-GFOM04/08 card Alarm Buzzer Status : 0:Normal 1:Buzzer
1.3.6.1.4.1.4756.20.471.20.1.103ColumngfomAlarmRDIStatusRemoteread-onlycurrentRemote FRM220-GFOM04/08 card Alarm RDI Status : 0:None 1:Remote Alarm
1.3.6.1.4.1.4756.20.471.20.1.104ColumngfomAlarmBuzzerRemoteread-writecurrentRemote FRM220-GFOM04/08 card Alarm Buzzer Active: 0:Disable 1:Enable
1.3.6.1.4.1.4756.20.471.20.1.105ColumngfomAlarmTriggerOpticalRemoteread-writecurrentRemote FRM220-GFOM04/08 card Alarm Trigger Optical: 0:No 1:Yes
1.3.6.1.4.1.4756.20.471.20.1.106ColumngfomAlarmTriggerLANRemoteread-writecurrentRemote FRM220-GFOM04/08 card Alarm Trigger LAN: 0:No 1:Yes
1.3.6.1.4.1.4756.20.471.20.1.107ColumngfomAlarmTriggerRDIRemoteread-writecurrentRemote FRM220-GFOM04/08 card Alarm Trigger RDI: 0:No 1:Yes
1.3.6.1.4.1.4756.20.471.20.1.108ColumngfomDeviceActiveRemoteread-onlycurrentRemote FRM220-GFOM04/08 card Device Active: 0:Disable 1:Enable
1.3.6.1.4.1.4756.20.471.20.1.109ColumngfomSetDefaultRemoteread-writecurrentForce remote FRM220-GFOM04/08 card to default : 0:Off 1:Action
1.3.6.1.4.1.4756.20.471.20.1.110ColumngfomPortResetRemoteread-writecurrentForce remote FRM220-GFOM04/08 card reset mode: 0:Off 1:Action
1.3.6.1.4.1.4756.20.471.20.1.111ColumngfomFx1DDVendorRemoteread-onlycurrentRemote FRM220-GFOM04/08 card fiber1 D/D information: Vendor name
1.3.6.1.4.1.4756.20.471.20.1.112ColumngfomFx1DDPartNoRemoteread-onlycurrentRemote FRM220-GFOM04/08 card fiber1 D/D information: Vendor part number
1.3.6.1.4.1.4756.20.471.20.1.113ColumngfomFx1DDFiberTypeRemoteread-onlycurrentRemote FRM220-GFOM04/08 card fiber1 D/D information: Fiber Type
1.3.6.1.4.1.4756.20.471.20.1.114ColumngfomFx1DDWaveLenRemoteread-onlycurrentRemote FRM220-GFOM04/08 card fiber1 D/D information: Wave length
1.3.6.1.4.1.4756.20.471.20.1.115ColumngfomFx1DDWaveLen2Remoteread-onlycurrentRemote FRM220-GFOM04/08 card fiber1 D/D information: Wave length 2
1.3.6.1.4.1.4756.20.471.20.1.116ColumngfomFx1DDLinkLenRemoteread-onlycurrentRemote FRM220-GFOM04/08 card fiber1 D/D information: Link length
1.3.6.1.4.1.4756.20.471.20.1.117ColumngfomFx1DDLenUnitRemoteread-onlycurrentRemote FRM220-GFOM04/08 card fiber1 D/D information: Length Unit
1.3.6.1.4.1.4756.20.471.20.1.118ColumngfomFx1DDStatusRemoteread-onlycurrentRemote FRM220-GFOM04/08 card fiber1 D/D information: Status Support
1.3.6.1.4.1.4756.20.471.20.1.119ColumngfomFx1DDRxSensRemoteread-onlycurrentRemote FRM220-GFOM04/08 card fiber1 D/D information: Rx Sensitivity
1.3.6.1.4.1.4756.20.471.20.1.120ColumngfomFx1DDTxPwrRemoteread-onlycurrentRemote FRM220-GFOM04/08 card fiber1 D/D information: Tx power
1.3.6.1.4.1.4756.20.471.20.1.121ColumngfomFx1DDRxPwrRemoteread-onlycurrentRemote FRM220-GFOM04/08 card fiber1 D/D information: Rx power
1.3.6.1.4.1.4756.20.471.20.1.122ColumngfomFx1DDTempRemoteread-onlycurrentRemote FRM220-GFOM04/08 card fiber1 D/D information: Temperature in degree C
1.3.6.1.4.1.4756.20.471.20.1.123ColumngfomFx1DDPwrMarginRemoteread-onlycurrentRemote FRM220-GFOM04/08 card fiber1 D/D information: Power margin
1.3.6.1.4.1.4756.20.471.20.1.124ColumngfomFx2DDVendorRemoteread-onlycurrentRemote FRM220-GFOM04/08 card fiber2 D/D information: Vendor name
1.3.6.1.4.1.4756.20.471.20.1.125ColumngfomFx2DDPartNoRemoteread-onlycurrentRemote FRM220-GFOM04/08 card fiber2 D/D information: Vendor part number
1.3.6.1.4.1.4756.20.471.20.1.126ColumngfomFx2DDFiberTypeRemoteread-onlycurrentRemote FRM220-GFOM04/08 card fiber2 D/D information: Fiber Type
1.3.6.1.4.1.4756.20.471.20.1.127ColumngfomFx2DDWaveLenRemoteread-onlycurrentRemote FRM220-GFOM04/08 card fiber2 D/D information: Wave length
1.3.6.1.4.1.4756.20.471.20.1.128ColumngfomFx2DDWaveLen2Remoteread-onlycurrentRemote FRM220-GFOM04/08 card fiber2 D/D information: Wave length 2
1.3.6.1.4.1.4756.20.471.20.1.129ColumngfomFx2DDLinkLenRemoteread-onlycurrentRemote FRM220-GFOM04/08 card fiber2 D/D information: Link length
1.3.6.1.4.1.4756.20.471.20.1.130ColumngfomFx2DDLenUnitRemoteread-onlycurrentRemote FRM220-GFOM04/08 card fiber2 D/D information: Length Unit
1.3.6.1.4.1.4756.20.471.20.1.131ColumngfomFx2DDStatusRemoteread-onlycurrentRemote FRM220-GFOM04/08 card fiber2 D/D information: Status Support
1.3.6.1.4.1.4756.20.471.20.1.132ColumngfomFx2DDRxSensRemoteread-onlycurrentRemote FRM220-GFOM04/08 card fiber2 D/D information: Rx Sensitivity
1.3.6.1.4.1.4756.20.471.20.1.133ColumngfomFx2DDTxPwrRemoteread-onlycurrentRemote FRM220-GFOM04/08 card fiber2 D/D information: Tx power
1.3.6.1.4.1.4756.20.471.20.1.134ColumngfomFx2DDRxPwrRemoteread-onlycurrentRemote FRM220-GFOM04/08 card fiber2 D/D information: Rx power
1.3.6.1.4.1.4756.20.471.20.1.135ColumngfomFx2DDTempRemoteread-onlycurrentRemote FRM220-GFOM04/08 card fiber2 D/D information: Temperature in degree C
1.3.6.1.4.1.4756.20.471.20.1.136ColumngfomFx2DDPwrMarginRemoteread-onlycurrentRemote FRM220-GFOM04/08 card fiber2 D/D information: Power margin
1.3.6.1.4.1.4756.20.471.20.1.137ColumngfomRemotePowerRemoteread-onlycurrentRemote FRM220-GFOM04 Remote power fail: 0:Ok 1:Abnormal
1.3.6.1.4.1.4756.20.471.20.1.138ColumngfomFEFRemoteread-onlycurrentRemote FRM220-GFOM04 FEF: 0:Off 1:Detected
1.3.6.1.4.1.4756.20.471.20.1.139ColumngfomPower1TypeRemoteread-onlycurrentRemote FMUX800 Power1 Type: 0:None 1:DV-24V 2:DV-48V 3:AC 4:Empty
1.3.6.1.4.1.4756.20.471.20.1.140ColumngfomPower1StatusRemoteread-onlycurrentRemote FMUX800 Power1 Status: 0:Abnormal 1:OK
1.3.6.1.4.1.4756.20.471.20.1.141ColumngfomPower2TypeRemoteread-onlycurrentRemote FMUX800 Power2 Type: 0:None 1:DV-24V 2:DV-48V 3:AC 4:Empty
1.3.6.1.4.1.4756.20.471.20.1.142ColumngfomPower2StatusRemoteread-onlycurrentRemote FMUX800 Power2 Status: 0:Abnormal 1:OK
1.3.6.1.4.1.4756.20.471.20.1.143ColumngfomUTP1LinkStatusRemoteread-onlycurrentRemote FMUX800 card UTP1 link state: 0:Link Down 1:Link Up
1.3.6.1.4.1.4756.20.471.20.1.144ColumngfomUTP1SpeedStatusRemoteread-onlycurrentRemote FMUX800 card UTP1 speed state
1.3.6.1.4.1.4756.20.471.20.1.145ColumngfomUTP1DuplexStatusRemoteread-onlycurrentRemote FMUX800 card UTP1 duplex state
1.3.6.1.4.1.4756.20.471.20.1.146ColumngfomUTP1PortActiveRemoteread-writecurrentRemote FMUX800 card UTP1 Port Active : 0:Disable 1:Enable
1.3.6.1.4.1.4756.20.471.20.1.147ColumngfomUTP1NegotiationRemoteread-writecurrentRemote FMUX800 card UTP1 Negotiation : 0:Auto 1:Manual
1.3.6.1.4.1.4756.20.471.20.1.148ColumngfomUTP1SpeedConfRemoteread-writecurrentRemote FMUX800 card UTP1 Speed : 0:10M 1:100M 2:1000M
1.3.6.1.4.1.4756.20.471.20.1.149ColumngfomUTP1DuplexConfRemoteread-writecurrentRemote FMUX800 card UTP1 Duplex : 0:Half 1:Full
1.3.6.1.4.1.4756.20.471.20.1.150ColumngfomUTP2LinkStatusRemoteread-onlycurrentRemote FMUX800 card UTP2 link state: 0:Link Down 1:Link Up
1.3.6.1.4.1.4756.20.471.20.1.151ColumngfomUTP2SpeedStatusRemoteread-onlycurrentRemote FMUX800 card UTP2 speed state
1.3.6.1.4.1.4756.20.471.20.1.152ColumngfomUTP2DuplexStatusRemoteread-onlycurrentRemote FMUX800 card UTP2 duplex state
1.3.6.1.4.1.4756.20.471.20.1.153ColumngfomUTP2PortActiveRemoteread-writecurrentRemote FMUX800 card UTP2 Port Active : 0:Disable 1:Enable
1.3.6.1.4.1.4756.20.471.20.1.154ColumngfomUTP2NegotiationRemoteread-writecurrentRemote FMUX800 card UTP2 Negotiation : 0:Auto 1:Manual
1.3.6.1.4.1.4756.20.471.20.1.155ColumngfomUTP2SpeedConfRemoteread-writecurrentRemote FMUX800 card UTP3 Speed : 0:10M 1:100M 2:1000M
1.3.6.1.4.1.4756.20.471.20.1.156ColumngfomUTP2DuplexConfRemoteread-writecurrentRemote FMUX800 card UTP3 Duplex : 0:Half 1:Full
1.3.6.1.4.1.4756.20.471.20.1.157ColumngfomUTP3LinkStatusRemoteread-onlycurrentRemote FMUX800 card UTP3 link state: 0:Link Down 1:Link Up
1.3.6.1.4.1.4756.20.471.20.1.158ColumngfomUTP3SpeedStatusRemoteread-onlycurrentRemote FMUX800 card UTP3 speed state
1.3.6.1.4.1.4756.20.471.20.1.159ColumngfomUTP3DuplexStatusRemoteread-onlycurrentRemote FMUX800 card UTP3 duplex state
1.3.6.1.4.1.4756.20.471.20.1.160ColumngfomUTP3PortActiveRemoteread-writecurrentRemote FMUX800 card UTP3 Port Active : 0:Disable 1:Enable
1.3.6.1.4.1.4756.20.471.20.1.161ColumngfomUTP3NegotiationRemoteread-writecurrentRemote FMUX800 card UTP3 Negotiation : 0:Auto 1:Manual
1.3.6.1.4.1.4756.20.471.20.1.162ColumngfomUTP3SpeedConfRemoteread-writecurrentRemote FMUX800 card UTP3 Speed : 0:10M 1:100M 2:1000M
1.3.6.1.4.1.4756.20.471.20.1.163ColumngfomUTP3DuplexConfRemoteread-writecurrentRemote FMUX800 card UTP3 Duplex : 0:Half 1:Full
1.3.6.1.4.1.4756.20.471.20.1.164ColumngfomUTP4LinkStatusRemoteread-onlycurrentRemote FMUX800 card UTP4 link state: 0:Link Down 1:Link Up
1.3.6.1.4.1.4756.20.471.20.1.165ColumngfomUTP4SpeedStatusRemoteread-onlycurrentRemote FMUX800 card UTP4 speed state
1.3.6.1.4.1.4756.20.471.20.1.166ColumngfomUTP4DuplexStatusRemoteread-onlycurrentRemote FMUX800 card UTP4 duplex state
1.3.6.1.4.1.4756.20.471.20.1.167ColumngfomUTP4PortActiveRemoteread-writecurrentRemote FMUX800 card UTP4 Port Active : 0:Disable 1:Enable
1.3.6.1.4.1.4756.20.471.20.1.168ColumngfomUTP4NegotiationRemoteread-writecurrentRemote FMUX800 card UTP4 Negotiation : 0:Auto 1:Manual
1.3.6.1.4.1.4756.20.471.20.1.169ColumngfomUTP4SpeedConfRemoteread-writecurrentRemote FMUX800 card UTP4 Speed : 0:10M 1:100M 2:1000M
1.3.6.1.4.1.4756.20.471.20.1.170ColumngfomUTP4DuplexConfRemoteread-writecurrentRemote FMUX800 card UTP4 Duplex : 0:Half 1:Full
1.3.6.1.4.1.4756.20.471.20.1.171ColumngfomAlarmRelayStatusRemoteread-onlycurrentRemote FMUX800 card Alarm Relay Status : 0:Normal 1:Alarm
1.3.6.1.4.1.4756.20.471.20.1.172ColumngfomAlarmRelayRemoteread-writecurrentRemote FMUX800 card Alarm Relay Active: 0:Disable 1:Enable
1.3.6.1.4.1.4756.20.471.20.1.173ColumngfomAlarmTriggerPowerRemoteread-writecurrentRemote FMUX800 card Alarm Trigger Power: 0:No 1:Yes
1.3.6.1.4.1.4756.20.480Nodef1000EASX2FLocalCards
1.3.6.1.4.1.4756.20.480.40Tablef1000EASX2FLocalTablenot-accessiblecurrentA list of local 1000EAS/X-2F card entries.
1.3.6.1.4.1.4756.20.480.40.1Rowf1000EASX2FLocalEntrynot-accessiblecurrentAn entry containing management information applicable to a particular local 1000EAS/X-2F card.
1.3.6.1.4.1.4756.20.480.40.1.1Columnf1000EASX2FChassisIndexLocalread-onlycurrentA unique value for each chassis ID. For CH20, it is the chassis ID. For CH08, it is always 0.
1.3.6.1.4.1.4756.20.480.40.1.2Columnf1000EASX2FSlotIndexLocalread-onlycurrentA unique value for each local card. It is the slot location number.
1.3.6.1.4.1.4756.20.480.40.1.3Columnf1000EASX2FCardHWVerLocalread-onlycurrentLocal device card hardware version x.xxx
1.3.6.1.4.1.4756.20.480.40.1.4Columnf1000EASX2FCardFWVerLocalread-onlycurrentLocal device card firmware version x.xxx
1.3.6.1.4.1.4756.20.480.40.1.5Columnf1000EASX2FCardCPLDVerLocalread-onlycurrentLocal device card CPLD version x.xxx
1.3.6.1.4.1.4756.20.480.40.1.6Columnf1000EASX2FCardFPGAVerLocalread-onlycurrentLocal device card FPGA version x.xxx
1.3.6.1.4.1.4756.20.480.40.1.7Columnf1000EASX2FModelLocalread-onlycurrentLocal 1000EAS/X Serial Type
1.3.6.1.4.1.4756.20.480.40.1.8Columnf1000EASX2FFiber1LinkLocalread-onlycurrentLocal device card fiber port 1 link status: 0:Down 1:Up
1.3.6.1.4.1.4756.20.480.40.1.9Columnf1000EASX2FFiber1OAMLoopedLocalread-onlycurrentLocal device card fiber port 1 OAM looped: 0:Off 1:on
1.3.6.1.4.1.4756.20.480.40.1.10Columnf1000EASX2FFiber1LBTestLocalread-writecurrentForce remote device card to do fiber port 1 LoopBack testing: 0:Off 1:Action
1.3.6.1.4.1.4756.20.480.40.1.11Columnf1000EASX2FFiber1OAMRLBStatusLocalread-onlycurrentRemote device card fiber port 1 LoopBack testing status: 0:Off 1:Ok 2:Fail
1.3.6.1.4.1.4756.20.480.40.1.12Columnf1000EASX2FFiber1RemoPwrAbLocalread-onlycurrentLocal device card fiber port 1 Remote Power status: 0:Abnormal 1:OK 2:None
1.3.6.1.4.1.4756.20.480.40.1.13Columnf1000EASX2FFiber1IngressRateLocalread-writecurrentLocal device card fiber 1 Ingress Rate Limit: 0 = Unlimit input format: 64k(K),100m(M),100 If doesn't input the unit, the default was Mega. Limite Rate : 64K ~…
1.3.6.1.4.1.4756.20.480.40.1.14Columnf1000EASX2FFiber1EgressRateLocalread-writecurrentLocal device card fiber 1 Egress Rate Limit: 0 = Unlimit input format: 64k(K),100m(M),100 If doesn't input the unit, the default was Mega. Limite Rate : 64K ~ …
1.3.6.1.4.1.4756.20.480.40.1.15Columnf1000EASX2FFiber2LinkLocalread-onlycurrentLocal device card fiber port 2 link status: 0:Down 1:Up
1.3.6.1.4.1.4756.20.480.40.1.16Columnf1000EASX2FFiber2OAMLoopedLocalread-onlycurrentLocal device card fiber port 2 OAM looped: 0:Off 1:on
1.3.6.1.4.1.4756.20.480.40.1.17Columnf1000EASX2FFiber2LBTestLocalread-writecurrentForce remote device card to do fiber port 2 LoopBack testing: 0:Off 1:Action
1.3.6.1.4.1.4756.20.480.40.1.18Columnf1000EASX2FFiber2OAMRLBStatusLocalread-onlycurrentRemote device card fiber port 1 LoopBack testing status: 0:Off 1:Ok 2:Fail
1.3.6.1.4.1.4756.20.480.40.1.19Columnf1000EASX2FFiber2RemoPwrAbLocalread-onlycurrentLocal device card fiber port 2 Remote Power status: 0:Abnormal 1:OK 2:None
1.3.6.1.4.1.4756.20.480.40.1.20Columnf1000EASX2FFiber2IngressRateLocalread-writecurrentLocal device card fiber 2 Ingress Rate Limit: 0 = Unlimit input format: 64k(K),100m(M),100 If doesn't input the unit, the default was Mega. Limite Rate : 64K ~…
1.3.6.1.4.1.4756.20.480.40.1.21Columnf1000EASX2FFiber2EgressRateLocalread-writecurrentLocal device card fiber 2 Egress Rate Limit: 0 = Unlimit input format: 64k(K),100m(M),100 If doesn't input the unit, the default was Mega. Limite Rate : 64K ~ …
1.3.6.1.4.1.4756.20.480.40.1.22Columnf1000EASX2FFiber1FEFLocalread-onlycurrentLocal device card fiber1 port FEF status: 0:Off 1:Detected
1.3.6.1.4.1.4756.20.480.40.1.23Columnf1000EASX2FFiber2FEFLocalread-onlycurrentLocal device card fiber2 port FEF status: 0:Off 1:Detected
1.3.6.1.4.1.4756.20.480.40.1.24Columnf1000EASX2FDeviceActiveLocalread-writecurrentLocal device card active mode: (It is read-only in local device.) 0:Disable 1:Enable
1.3.6.1.4.1.4756.20.480.40.1.25Columnf1000EASX2FDeviceResetLocalread-writecurrentForce local device card to reset mode: 0:Off 1:Action
1.3.6.1.4.1.4756.20.480.40.1.26Columnf1000EASX2FFiber1ActiveLocalread-writecurrentLocal device fiber port 1 active mode: 0:Disable 1:Enable
1.3.6.1.4.1.4756.20.480.40.1.27Columnf1000EASX2FFiber2ActiveLocalread-writecurrentLocal device fiber port 2 active mode: 0:Disable 1:Enable
1.3.6.1.4.1.4756.20.480.40.1.28Columnf1000EASX2FOamChAModeLocalread-writecurrentLocal device OAM Channel A mode: 0:Disable 1:passive 2:Active
1.3.6.1.4.1.4756.20.480.40.1.29Columnf1000EASX2FOamChBModeLocalread-writecurrentLocal device OAM Channel B mode: 0:Disable 1:passive 2:Active
1.3.6.1.4.1.4756.20.480.40.1.30Columnf1000EASX2FOamMaxPDUsLocalread-writecurrentLocal device OAM max OAMPDU size: 60-1518 Octets
1.3.6.1.4.1.4756.20.480.40.1.31Columnf1000EASX2FFiber1AlsLocalread-writecurrentLocal device card port 1 Auto Laser Shutdown mode: 0:Disable 1:Enable
1.3.6.1.4.1.4756.20.480.40.1.32Columnf1000EASX2FFiber2AlsLocalread-writecurrentLocal device card port 2 Auto Laser Shutdown mode: 0:Disable 1:Enable
1.3.6.1.4.1.4756.20.480.40.1.33Columnf1000EASX2FPauseFrameLocalread-writecurrentLocal device card pause frame mode: 0:Disable 1:Enable
1.3.6.1.4.1.4756.20.480.40.1.34Columnf1000EASX2FSendFHRtoALocalread-writecurrentLocal device card port 1 send Fiber Hardware Reset to remote: 0:No action 1:Action
1.3.6.1.4.1.4756.20.480.40.1.35Columnf1000EASX2FSendFHRtoBLocalread-writecurrentLocal device card port 2 send Fiber Hardware Reset to remote: 0:No action 1:Action
1.3.6.1.4.1.4756.20.480.40.1.36Columnf1000EASX2FFiber1LLFDepPort2Localread-writecurrentLocal device card port 1 Link Loss Forwarding depends on port 2 Fiber Rx link: 0:don't care 1:selected
1.3.6.1.4.1.4756.20.480.40.1.37Columnf1000EASX2FFiber2LLFDepPort1Localread-writecurrentLocal device card port 2 Link Loss Forwarding depends on port 1 Fiber Rx link: 0:don't care 1:selected
1.3.6.1.4.1.4756.20.480.40.1.38Columnf1000EASX2FAdvanceFunsLocalread-writecurrentLocal device card Switch functions mode: 0:Normal 5:Static 802.1Q VLAN 6:Spanning Tree Protocol 7:802.1Q VLAN Trunk 9:Q in Q VLAN 11:Spanning Tree Protocol and…
1.3.6.1.4.1.4756.20.480.40.1.39Columnf1000EASX2FFiber1InfoROM1Localread-onlycurrentLocal device card port 1 INFORemoteOM information 1 valid: 0:Invalid 1:Valid
1.3.6.1.4.1.4756.20.480.40.1.40Columnf1000EASX2FFiber1InfoROM2Localread-onlycurrentLocal device card port 1 INFORemoteOM information 2 valid: 0:Invalid 1:Valid(replacing D/D function
1.3.6.1.4.1.4756.20.480.40.1.41Columnf1000EASX2FFiber2InfoROM1Localread-onlycurrentLocal device card port 2 INFORemoteOM information 1 valid: 0:Invalid 1:Valid
1.3.6.1.4.1.4756.20.480.40.1.42Columnf1000EASX2FFiber2InfoROM2Localread-onlycurrentLocal device card port 2 INFORemoteOM information 2 valid: 0:Invalid 1:Valid(replacing D/D function)
1.3.6.1.4.1.4756.20.480.40.1.43Columnf1000EASX2FFiber1InfoSN1Localread-onlycurrentLocal device card port 1 INFORemoteOM S/N 1
1.3.6.1.4.1.4756.20.480.40.1.44Columnf1000EASX2FFiber1InfoSN2Localread-onlycurrentLocal device card port 1 INFORemoteOM S/N 2
1.3.6.1.4.1.4756.20.480.40.1.45Columnf1000EASX2FFiber2InfoSN1Localread-onlycurrentLocal device card port 2 INFORemoteOM S/N 1
1.3.6.1.4.1.4756.20.480.40.1.46Columnf1000EASX2FFiber2InfoSN2Localread-onlycurrentLocal device card port 2 INFORemoteOM S/N 2
1.3.6.1.4.1.4756.20.480.40.1.47Columnf1000EASX2FFiber1DDLocalread-onlycurrentLocal device card fiber port 1 Digital Diagnostic function: 0:No 1:Yes
1.3.6.1.4.1.4756.20.480.40.1.48Columnf1000EASX2FFiber1DDVendorLocalread-onlycurrentLocal device card fiber port 1 D/D information: Vendor name
1.3.6.1.4.1.4756.20.480.40.1.49Columnf1000EASX2FFiber1DDPartNoLocalread-onlycurrentLocal device card fiber port 1 D/D information: Vendor part number
1.3.6.1.4.1.4756.20.480.40.1.50Columnf1000EASX2FFiber1DDFiberTypeLocalread-onlycurrentLocal device card fiber port 1 D/D information: Fiber Type
1.3.6.1.4.1.4756.20.480.40.1.51Columnf1000EASX2FFiber1DDWaveLenLocalread-onlycurrentLocal device card fiber port 1 D/D information: Wave length
1.3.6.1.4.1.4756.20.480.40.1.52Columnf1000EASX2FFiber1DDWaveLen2Localread-onlycurrentLocal device card fiber port 1 D/D information: Wave length 2
1.3.6.1.4.1.4756.20.480.40.1.53Columnf1000EASX2FFiber1DDLinkLenLocalread-onlycurrentLocal device card fiber port 1 D/D information: Link length
1.3.6.1.4.1.4756.20.480.40.1.54Columnf1000EASX2FFiber1DDLenUnitLocalread-onlycurrentLocal device card fiber port 1 D/D information: Length Unit
1.3.6.1.4.1.4756.20.480.40.1.55Columnf1000EASX2FFiber1DDStatusLocalread-onlycurrentLocal device card fiber port 1 D/D information: Status Support
1.3.6.1.4.1.4756.20.480.40.1.56Columnf1000EASX2FFiber1DDRxSensLocalread-onlycurrentLocal device card fiber port 1 D/D information: Rx Sensitivity
1.3.6.1.4.1.4756.20.480.40.1.57Columnf1000EASX2FFiber1DDTxPWRLocalread-onlycurrentLocal device card fiber port 1 D/D information: Tx power
1.3.6.1.4.1.4756.20.480.40.1.58Columnf1000EASX2FFiber1DDRxPWRLocalread-onlycurrentLocal device card fiber port 1 D/D information: Rx power
1.3.6.1.4.1.4756.20.480.40.1.59Columnf1000EASX2FFiber1DDTempLocalread-onlycurrentLocal device card fiber port 1 D/D information: Temperature in degree C
1.3.6.1.4.1.4756.20.480.40.1.60Columnf1000EASX2FFiber1DDPWRMarginLocalread-onlycurrentLocal device card fiber port 1 D/D information: Power margin
1.3.6.1.4.1.4756.20.480.40.1.61Columnf1000EASX2FFiber1DDPWRLossLocalread-onlycurrentLocal device card fiber port 1 D/D information: Power loss
1.3.6.1.4.1.4756.20.480.40.1.62Columnf1000EASX2FFiber2DDLocalread-onlycurrentLocal device card fiber port 2 Digital Diagnostic function: 0:No 1:Yes
1.3.6.1.4.1.4756.20.480.40.1.63Columnf1000EASX2FFiber2DDVendorLocalread-onlycurrentLocal device card fiber port 2 D/D information: Vendor name
1.3.6.1.4.1.4756.20.480.40.1.64Columnf1000EASX2FFiber2DDPartNoLocalread-onlycurrentLocal device card fiber port 2 D/D information: Vendor part number
1.3.6.1.4.1.4756.20.480.40.1.65Columnf1000EASX2FFiber2DDFiberTypeLocalread-onlycurrentLocal device card fiber port 2 D/D information: Fiber Type
1.3.6.1.4.1.4756.20.480.40.1.66Columnf1000EASX2FFiber2DDWaveLenLocalread-onlycurrentLocal device card fiber port 2 D/D information: Wave length
1.3.6.1.4.1.4756.20.480.40.1.67Columnf1000EASX2FFiber2DDWaveLen2Localread-onlycurrentLocal device card fiber port 2 D/D information: Wave length 2
1.3.6.1.4.1.4756.20.480.40.1.68Columnf1000EASX2FFiber2DDLinkLenLocalread-onlycurrentLocal device card fiber port 2 D/D information: Link length
1.3.6.1.4.1.4756.20.480.40.1.69Columnf1000EASX2FFiber2DDLenUnitLocalread-onlycurrentLocal device card fiber port 2 D/D information: Length Unit
1.3.6.1.4.1.4756.20.480.40.1.70Columnf1000EASX2FFiber2DDStatusLocalread-onlycurrentLocal device card fiber port 2 D/D information: Status Support
1.3.6.1.4.1.4756.20.480.40.1.71Columnf1000EASX2FFiber2DDRxSensLocalread-onlycurrentLocal device card fiber port 2 D/D information: Rx Sensitivity
1.3.6.1.4.1.4756.20.480.40.1.72Columnf1000EASX2FFiber2DDTxPWRLocalread-onlycurrentLocal device card fiber port 2 D/D information: Tx power
1.3.6.1.4.1.4756.20.480.40.1.73Columnf1000EASX2FFiber2DDRxPWRLocalread-onlycurrentLocal device card fiber port 2 D/D information: Rx power
1.3.6.1.4.1.4756.20.480.40.1.74Columnf1000EASX2FFiber2DDTempLocalread-onlycurrentLocal device card fiber port 2 D/D information: Temperature in degree C
1.3.6.1.4.1.4756.20.480.40.1.75Columnf1000EASX2FFiber2DDPWRMarginLocalread-onlycurrentLocal device card fiber port 2 D/D information: Power margin
1.3.6.1.4.1.4756.20.480.40.1.76Columnf1000EASX2FFiber2DDPWRLossLocalread-onlycurrentLocal device card fiber port 2 D/D information: Power loss
1.3.6.1.4.1.4756.20.480.40.1.77Columnf1000EASX2FClrRMONCntsLocalread-writecurrentClear local device card RMON IN/OUT counters: 0:No action 1:Action
1.3.6.1.4.1.4756.20.480.40.1.78Columnf1000EASX2FFiber1RMONInLocalread-onlycurrentLocal device card port 1 RMON IN counter.
1.3.6.1.4.1.4756.20.480.40.1.79Columnf1000EASX2FFiber1RMONOutLocalread-onlycurrentLocal device card port 1 RMON OUT counter.
1.3.6.1.4.1.4756.20.480.40.1.80Columnf1000EASX2FFiber2RMONInLocalread-onlycurrentLocal device card port 2 RMON IN counter.
1.3.6.1.4.1.4756.20.480.40.1.81Columnf1000EASX2FFiber2RMONOutLocalread-onlycurrentLocal device card port 2 RMON OUT counter.
1.3.6.1.4.1.4756.20.480.40.1.82Columnf1000EASX2FClrOAMCntsLocalread-writecurrentClear local device card OAM counters: 0:No action 1:Action
1.3.6.1.4.1.4756.20.480.40.1.83Columnf1000EASX2FIpModeLocalread-writecurrentOn Rack Ip Mode: 0:Enable 1:Disable
1.3.6.1.4.1.4756.20.480.40.1.84Columnf1000EASX2FOamChATxLocalread-onlycurrentLocal device OAM Channel A TX OAMPDU frame count
1.3.6.1.4.1.4756.20.480.40.1.85Columnf1000EASX2FOamChARxLocalread-onlycurrentLocal device OAM Channel A RX OAMPDU frame count
1.3.6.1.4.1.4756.20.480.40.1.86Columnf1000EASX2FOamInfoChATxLocalread-onlycurrentLocal device OAM Channel A TX Information OAMPDU frame count
1.3.6.1.4.1.4756.20.480.40.1.87Columnf1000EASX2FOamInfoChARxLocalread-onlycurrentLocal device OAM Channel A RX Information OAMPDU frame count
1.3.6.1.4.1.4756.20.480.40.1.88Columnf1000EASX2FOamEventChATxLocalread-onlycurrentLocal device OAM Channel A TX Event OAMPDU frame count
1.3.6.1.4.1.4756.20.480.40.1.89Columnf1000EASX2FOamUniEvtChARxLocalread-onlycurrentLocal device OAM Channel A RX Unique Event OAMPDU frame count
1.3.6.1.4.1.4756.20.480.40.1.90Columnf1000EASX2FOamDupEvtChARxLocalread-onlycurrentLocal device OAM Channel A RX Duplicate Event OAMPDU frame count
1.3.6.1.4.1.4756.20.480.40.1.91Columnf1000EASX2FOamLbChATxLocalread-onlycurrentLocal device OAM Channel A TX Loopback Control OAMPDU frame count
1.3.6.1.4.1.4756.20.480.40.1.92Columnf1000EASX2FOamLbChARxLocalread-onlycurrentLocal device OAM Channel A RX Loopback Control OAMPDU frame count
1.3.6.1.4.1.4756.20.480.40.1.93Columnf1000EASX2FOamVarReqChATxLocalread-onlycurrentLocal device OAM Channel A TX Variable Request OAMPDU frame count
1.3.6.1.4.1.4756.20.480.40.1.94Columnf1000EASX2FOamVarReqChARxLocalread-onlycurrentLocal device OAM Channel A RX Variable Request OAMPDU frame count
1.3.6.1.4.1.4756.20.480.40.1.95Columnf1000EASX2FOamVarRspChATxLocalread-onlycurrentLocal device OAM Channel A TX Variable Response OAMPDU frame count
1.3.6.1.4.1.4756.20.480.40.1.96Columnf1000EASX2FOamVarRspChARxLocalread-onlycurrentLocal device OAM Channel A RX Variable Response OAMPDU frame count
1.3.6.1.4.1.4756.20.480.40.1.97Columnf1000EASX2FOamOuiChATxLocalread-onlycurrentLocal device OAM Channel A TX OUI OAMPDU frame count
1.3.6.1.4.1.4756.20.480.40.1.98Columnf1000EASX2FOamOuiChARxLocalread-onlycurrentLocal device OAM Channel A RX OUI OAMPDU frame count
1.3.6.1.4.1.4756.20.480.40.1.99Columnf1000EASX2FOamUnknowChARxLocalread-onlycurrentLocal device OAM Channel A RX Unsupported OAMPDU frame count
1.3.6.1.4.1.4756.20.480.40.1.100Columnf1000EASX2FOamChBTxLocalread-onlycurrentLocal device OAM Channel B TX OAMPDU frame count
1.3.6.1.4.1.4756.20.480.40.1.101Columnf1000EASX2FOamChBRxLocalread-onlycurrentLocal device OAM Channel B RX OAMPDU frame count
1.3.6.1.4.1.4756.20.480.40.1.102Columnf1000EASX2FOamInfoChBTxLocalread-onlycurrentLocal device OAM Channel B TX Information OAMPDU frame count
1.3.6.1.4.1.4756.20.480.40.1.103Columnf1000EASX2FOamInfoChBRxLocalread-onlycurrentLocal device OAM Channel B RX Information OAMPDU frame count
1.3.6.1.4.1.4756.20.480.40.1.104Columnf1000EASX2FOamEventChBTxLocalread-onlycurrentLocal device OAM Channel B TX Event OAMPDU frame count
1.3.6.1.4.1.4756.20.480.40.1.105Columnf1000EASX2FOamUniEvtChBRxLocalread-onlycurrentLocal device OAM Channel B RX Unique Event OAMPDU frame count
1.3.6.1.4.1.4756.20.480.40.1.106Columnf1000EASX2FOamDupEvtChBRxLocalread-onlycurrentLocal device OAM Channel B RX Duplicate Event OAMPDU frame count
1.3.6.1.4.1.4756.20.480.40.1.107Columnf1000EASX2FOamLbChBTxLocalread-onlycurrentLocal device OAM Channel B TX Loopback Control OAMPDU frame count
1.3.6.1.4.1.4756.20.480.40.1.108Columnf1000EASX2FOamLbChBRxLocalread-onlycurrentLocal device OAM Channel B RX Loopback Control OAMPDU frame count
1.3.6.1.4.1.4756.20.480.40.1.109Columnf1000EASX2FOamVarReqChBTxLocalread-onlycurrentLocal device OAM Channel B TX Variable Request OAMPDU frame count
1.3.6.1.4.1.4756.20.480.40.1.110Columnf1000EASX2FOamVarReqChBRxLocalread-onlycurrentLocal device OAM Channel B RX Variable Request OAMPDU frame count
1.3.6.1.4.1.4756.20.480.40.1.111Columnf1000EASX2FOamVarRspChBTxLocalread-onlycurrentLocal device OAM Channel B TX Variable Response OAMPDU frame count
1.3.6.1.4.1.4756.20.480.40.1.112Columnf1000EASX2FOamVarRspChBRxLocalread-onlycurrentLocal device OAM Channel B RX Variable Response OAMPDU frame count
1.3.6.1.4.1.4756.20.480.40.1.113Columnf1000EASX2FOamOuiChBTxLocalread-onlycurrentLocal device OAM Channel B TX OUI OAMPDU frame count
1.3.6.1.4.1.4756.20.480.40.1.114Columnf1000EASX2FOamOuiChBRxLocalread-onlycurrentLocal device OAM Channel B RX OUI OAMPDU frame count
1.3.6.1.4.1.4756.20.480.40.1.115Columnf1000EASX2FOamUnknowChBRxLocalread-onlycurrentLocal device OAM Channel B RX Unsupported OAMPDU frame count
1.3.6.1.4.1.4756.20.480.40.1.116Columnf1000EASX2FFiber1SpeedLocalread-writecurrentLocal device Fiber 1 speed : 0:1000Auto 1:1000FDX 2:100FDX
1.3.6.1.4.1.4756.20.480.40.1.117Columnf1000EASX2FFiber2SpeedLocalread-writecurrentLocal device Fiber 2 speed : 0:1000Auto 1:1000FDX 2:100FDX
1.3.6.1.4.1.4756.20.480.40.1.118Columnf1000EASX2FMacLearningLocalread-writecurrentLocal device Mac learning : 0:Disable 1:Enable
1.3.6.1.4.1.4756.20.480.40.1.119Columnf1000EASX2FManagementVIDLocalread-writecurrentLocal device Management VID :
1.3.6.1.4.1.4756.20.480.40.1.120Columnf1000EASX2FTagTypeLocalread-writecurrentLocal device Tag Type (HEX) :
1.3.6.1.4.1.4756.20.480.40.1.121Columnf1000EASX2FPort1VIDLocalread-writecurrentLocal device Port 1 VID :
1.3.6.1.4.1.4756.20.480.40.1.122Columnf1000EASX2FPort2VIDLocalread-writecurrentLocal device Port 2 VID :
1.3.6.1.4.1.4756.20.480.40.1.123Columnf1000EASX2FPort1QinQLocalread-writecurrentLocal device Port 1 Q in Q Support : 1:Disable 2:Enable
1.3.6.1.4.1.4756.20.480.40.1.124Columnf1000EASX2FPort2QinQLocalread-writecurrentLocal device Port 2 Q in Q Support : 1:Disable 2:Enable
1.3.6.1.4.1.4756.20.480.40.1.125Columnf1000EASX2FVID1Localread-writecurrentLocal device VID 1:
1.3.6.1.4.1.4756.20.480.40.1.126Columnf1000EASX2FVID2Localread-writecurrentLocal device VID 2:
1.3.6.1.4.1.4756.20.480.40.1.127Columnf1000EASX2FVID3Localread-writecurrentLocal device VID 3:
1.3.6.1.4.1.4756.20.480.40.1.128Columnf1000EASX2FVID4Localread-writecurrentLocal device VID 4:
1.3.6.1.4.1.4756.20.480.40.1.129Columnf1000EASX2FVID5Localread-writecurrentLocal device VID 5:
1.3.6.1.4.1.4756.20.480.40.1.130Columnf1000EASX2FVID6Localread-writecurrentLocal device VID 6:
1.3.6.1.4.1.4756.20.480.40.1.131Columnf1000EASX2FVID7Localread-writecurrentLocal device VID 7:
1.3.6.1.4.1.4756.20.480.40.1.132Columnf1000EASX2FVID8Localread-writecurrentLocal device VID 8:
1.3.6.1.4.1.4756.20.480.40.1.133Columnf1000EASX2FVID9Localread-writecurrentLocal device VID 9:
1.3.6.1.4.1.4756.20.480.40.1.134Columnf1000EASX2FVID10Localread-writecurrentLocal device VID 10:
1.3.6.1.4.1.4756.20.480.40.1.135Columnf1000EASX2FVID11Localread-writecurrentLocal device VID 11:
1.3.6.1.4.1.4756.20.480.40.1.136Columnf1000EASX2FVID12Localread-writecurrentLocal device VID 12:
1.3.6.1.4.1.4756.20.480.40.1.137Columnf1000EASX2FVID13Localread-writecurrentLocal device VID 13:
1.3.6.1.4.1.4756.20.480.40.1.138Columnf1000EASX2FVID14Localread-writecurrentLocal device VID 14:
1.3.6.1.4.1.4756.20.480.40.1.139Columnf1000EASX2FVID15Localread-writecurrentLocal device VID 15:
1.3.6.1.4.1.4756.20.480.40.1.140Columnf1000EASX2FVID16Localread-writecurrentLocal device VID 16:
1.3.6.1.4.1.4756.20.480.40.1.141Columnf1000EASX2FPort1Member1Localread-writecurrentLocal device card port 1 member: 0:Unmodify 1:Untagged 2:Tagged 3:Nonmember
1.3.6.1.4.1.4756.20.480.40.1.142Columnf1000EASX2FPort1Member2Localread-writecurrentLocal device card port 1 member 2: 0:Unmodify 1:Untagged 2:Tagged 3:Nonmember
1.3.6.1.4.1.4756.20.480.40.1.143Columnf1000EASX2FPort1Member3Localread-writecurrentLocal device card port 1 member 3: 0:Unmodify 1:Untagged 2:Tagged 3:Nonmember
1.3.6.1.4.1.4756.20.480.40.1.144Columnf1000EASX2FPort1Member4Localread-writecurrentLocal device card port 1 member 4: 0:Unmodify 1:Untagged 2:Tagged 3:Nonmember
1.3.6.1.4.1.4756.20.480.40.1.145Columnf1000EASX2FPort1Member5Localread-writecurrentLocal device card port 1 member 5: 0:Unmodify 1:Untagged 2:Tagged 3:Nonmember
1.3.6.1.4.1.4756.20.480.40.1.146Columnf1000EASX2FPort1Member6Localread-writecurrentLocal device card port 1 member 6: 0:Unmodify 1:Untagged 2:Tagged 3:Nonmember
1.3.6.1.4.1.4756.20.480.40.1.147Columnf1000EASX2FPort1Member7Localread-writecurrentLocal device card port 1 member 7: 0:Unmodify 1:Untagged 2:Tagged 3:Nonmember
1.3.6.1.4.1.4756.20.480.40.1.148Columnf1000EASX2FPort1Member8Localread-writecurrentLocal device card port 1 member 8: 0:Unmodify 1:Untagged 2:Tagged 3:Nonmember
1.3.6.1.4.1.4756.20.480.40.1.149Columnf1000EASX2FPort1Member9Localread-writecurrentLocal device card port 1 member 9: 0:Unmodify 1:Untagged 2:Tagged 3:Nonmember
1.3.6.1.4.1.4756.20.480.40.1.150Columnf1000EASX2FPort1Member10Localread-writecurrentLocal device card port 1 member 10: 0:Unmodify 1:Untagged 2:Tagged 3:Nonmember
1.3.6.1.4.1.4756.20.480.40.1.151Columnf1000EASX2FPort1Member11Localread-writecurrentLocal device card port 1 member 11: 0:Unmodify 1:Untagged 2:Tagged 3:Nonmember
1.3.6.1.4.1.4756.20.480.40.1.152Columnf1000EASX2FPort1Member12Localread-writecurrentLocal device card port 1 member 12: 0:Unmodify 1:Untagged 2:Tagged 3:Nonmember
1.3.6.1.4.1.4756.20.480.40.1.153Columnf1000EASX2FPort1Member13Localread-writecurrentLocal device card port 1 member 13: 0:Unmodify 1:Untagged 2:Tagged 3:Nonmember
1.3.6.1.4.1.4756.20.480.40.1.154Columnf1000EASX2FPort1Member14Localread-writecurrentLocal device card port 1 member 14: 0:Unmodify 1:Untagged 2:Tagged 3:Nonmember
1.3.6.1.4.1.4756.20.480.40.1.155Columnf1000EASX2FPort1Member15Localread-writecurrentLocal device card port 1 member 15: 0:Unmodify 1:Untagged 2:Tagged 3:Nonmember
1.3.6.1.4.1.4756.20.480.40.1.156Columnf1000EASX2FPort1Member16Localread-writecurrentLocal device card port 1 member 16: 0:Unmodify 1:Untagged 2:Tagged 3:Nonmember
1.3.6.1.4.1.4756.20.480.40.1.157Columnf1000EASX2FPort2Member1Localread-writecurrentLocal device card port 2 member: 0:Unmodify 1:Untagged 2:Tagged 3:Nonmember
1.3.6.1.4.1.4756.20.480.40.1.158Columnf1000EASX2FPort2Member2Localread-writecurrentLocal device card port 2 member 2: 0:Unmodify 1:Untagged 2:Tagged 3:Nonmember
1.3.6.1.4.1.4756.20.480.40.1.159Columnf1000EASX2FPort2Member3Localread-writecurrentLocal device card port 2 member 3: 0:Unmodify 1:Untagged 2:Tagged 3:Nonmember
1.3.6.1.4.1.4756.20.480.40.1.160Columnf1000EASX2FPort2Member4Localread-writecurrentLocal device card port 2 member 4: 0:Unmodify 1:Untagged 2:Tagged 3:Nonmember
1.3.6.1.4.1.4756.20.480.40.1.161Columnf1000EASX2FPort2Member5Localread-writecurrentLocal device card port 2 member 5: 0:Unmodify 1:Untagged 2:Tagged 3:Nonmember
1.3.6.1.4.1.4756.20.480.40.1.162Columnf1000EASX2FPort2Member6Localread-writecurrentLocal device card port 2 member 6: 0:Unmodify 1:Untagged 2:Tagged 3:Nonmember
1.3.6.1.4.1.4756.20.480.40.1.163Columnf1000EASX2FPort2Member7Localread-writecurrentLocal device card port 2 member 7: 0:Unmodify 1:Untagged 2:Tagged 3:Nonmember
1.3.6.1.4.1.4756.20.480.40.1.164Columnf1000EASX2FPort2Member8Localread-writecurrentLocal device card port 2 member 8: 0:Unmodify 1:Untagged 2:Tagged 3:Nonmember
1.3.6.1.4.1.4756.20.480.40.1.165Columnf1000EASX2FPort2Member9Localread-writecurrentLocal device card port 2 member 9: 0:Unmodify 1:Untagged 2:Tagged 3:Nonmember
1.3.6.1.4.1.4756.20.480.40.1.166Columnf1000EASX2FPort2Member10Localread-writecurrentLocal device card port 2 member 10: 0:Unmodify 1:Untagged 2:Tagged 3:Nonmember
1.3.6.1.4.1.4756.20.480.40.1.167Columnf1000EASX2FPort2Member11Localread-writecurrentLocal device card port 2 member 11: 0:Unmodify 1:Untagged 2:Tagged 3:Nonmember
1.3.6.1.4.1.4756.20.480.40.1.168Columnf1000EASX2FPort2Member12Localread-writecurrentLocal device card port 2 member 12: 0:Unmodify 1:Untagged 2:Tagged 3:Nonmember
1.3.6.1.4.1.4756.20.480.40.1.169Columnf1000EASX2FPort2Member13Localread-writecurrentLocal device card port 2 member 13: 0:Unmodify 1:Untagged 2:Tagged 3:Nonmember
1.3.6.1.4.1.4756.20.480.40.1.170Columnf1000EASX2FPort2Member14Localread-writecurrentLocal device card port 2 member 14: 0:Unmodify 1:Untagged 2:Tagged 3:Nonmember
1.3.6.1.4.1.4756.20.480.40.1.171Columnf1000EASX2FPort2Member15Localread-writecurrentLocal device card port 2 member 15: 0:Unmodify 1:Untagged 2:Tagged 3:Nonmember
1.3.6.1.4.1.4756.20.480.40.1.172Columnf1000EASX2FPort2Member16Localread-writecurrentLocal device card port 2 member 16: 0:Unmodify 1:Untagged 2:Tagged 3:Nonmember
1.3.6.1.4.1.4756.20.480.40.1.173Columnf1000EASX2FIpAddressLocalread-writecurrentLocal device IP address
1.3.6.1.4.1.4756.20.480.40.1.174Columnf1000EASX2FNetMaskLocalread-writecurrentLocal device Netmask
1.3.6.1.4.1.4756.20.480.40.1.175Columnf1000EASX2FGateWayLocalread-writecurrentLocal device Gateway
1.3.6.1.4.1.4756.20.480.40.1.176Columnf1000EASX2FSetDefaultLocalread-writecurrentLocal device set to default
1.3.6.1.4.1.4756.20.480.40.1.177Columnf1000EASX2FFx1LinkAlarmLocalread-writecurrentLocal device fiber 1 link alarm 0:Disable 1:Enable
1.3.6.1.4.1.4756.20.480.40.1.178Columnf1000EASX2FFx2LinkAlarmLocalread-writecurrentLocal device fiber 2 link alarm 0:Disable 1:Enable
1.3.6.1.4.1.4756.20.480.40.1.179Columnf1000EASX2FPingStatusLocalread-onlycurrentLocal device icmp ping status Show Ping Status 0: Normal 1: Not Ready 2: 5 packets transmitted, 5 received, 0 packet loss. (Ping OK) 3: 5 packets transmitted, …
1.3.6.1.4.1.4756.20.480.40.1.180Columnf1000EASX2FPingIpAddressLocalread-writecurrentLocal device ping IP address
1.3.6.1.4.1.4756.20.480.40.1.181Columnf1000EASX2FPingStartLocalread-writecurrentLocal device ping start 0:Off 1:Action
1.3.6.1.4.1.4756.20.480.40.1.182Columnf1000EASX2FRemoteTLPTLocalread-writecurrentLocal device Remote TLPT mode : 0:Disalbe 1:Remote A 2:Remote B
1.3.6.1.4.1.4756.20.480.40.1.183Columnf1000EASX2FFx1LBTLocalread-writecurrentFRM220-1000EAS/X-2F Fiber 1 LoopBack Test: 0: Disalbe 1: Enable 2: Not Support
1.3.6.1.4.1.4756.20.480.40.1.184Columnf1000EASX2FFx2LBTLocalread-writecurrentFRM220-1000EAS/X-2F Fiber 2 LoopBack Test: 0: Disalbe 1: Enable 2: Not Support
1.3.6.1.4.1.4756.20.481Nodef1000EASX2FRemoteACards
1.3.6.1.4.1.4756.20.481.40Tablef1000EASX2FRemoteATablenot-accessiblecurrentA list of RemoteA 1000EAS/X-2F card entries.
1.3.6.1.4.1.4756.20.481.40.1Rowf1000EASX2FRemoteAEntrynot-accessiblecurrentAn entry containing management information applicable to a particular RemoteA 1000EAS/X-2F card.
1.3.6.1.4.1.4756.20.481.40.1.1Columnf1000EASX2FChassisIndexRemoteAread-onlycurrentA unique value for each chassis ID. For CH20, it is the chassis ID. For CH08, it is always 0.
1.3.6.1.4.1.4756.20.481.40.1.2Columnf1000EASX2FSlotIndexRemoteAread-onlycurrentA unique value for each local card. It is the slot location number.
1.3.6.1.4.1.4756.20.481.40.1.3Columnf1000EASX2FCardHWVerRemoteAread-onlycurrentRemoteA device card hardware version x.xxx
1.3.6.1.4.1.4756.20.481.40.1.4Columnf1000EASX2FCardFWVerRemoteAread-onlycurrentRemoteA device card firmware version x.xxx
1.3.6.1.4.1.4756.20.481.40.1.5Columnf1000EASX2FCardCPLDVerRemoteAread-onlycurrentRemoteA device card CPLD version x.xxx
1.3.6.1.4.1.4756.20.481.40.1.6Columnf1000EASX2FCardFPGAVerRemoteAread-onlycurrentRemoteA device card FPGA version x.xxx
1.3.6.1.4.1.4756.20.481.40.1.7Columnf1000EASX2FModelRemoteAread-onlycurrentRemoteA 1000EAS/X Serial Type
1.3.6.1.4.1.4756.20.481.40.1.8Columnf1000EASX2FFiber1LinkRemoteAread-onlycurrentRemoteA device card fiber port 1 link status: 0:Down 1:Up
1.3.6.1.4.1.4756.20.481.40.1.9Columnf1000EASX2FFiber1OAMLoopedRemoteAread-onlycurrentRemoteA device card fiber port 1 OAM looped: 0:Off 1:on
1.3.6.1.4.1.4756.20.481.40.1.10Columnf1000EASX2FFiber1LBTestRemoteAread-writecurrentForce remote device card to do fiber port 1 LoopBack testing: 0:Off 1:Action
1.3.6.1.4.1.4756.20.481.40.1.11Columnf1000EASX2FFiber1OAMRLBStatusRemoteAread-onlycurrentRemote device card fiber port 1 LoopBack testing status: 0:Off 1:Ok 2:Fail
1.3.6.1.4.1.4756.20.481.40.1.12Columnf1000EASX2FFiber1RemoPwrAbRemoteAread-onlycurrentRemoteA device card fiber port 1 Remote Power status: 0:Abnormal 1:OK 2:None
1.3.6.1.4.1.4756.20.481.40.1.13Columnf1000EASX2FFiber1IngressRateRemoteAread-writecurrentRemoteA device card fiber 1 Ingress Rate Limit: 0 = Unlimit input format: 64k(K),100m(M),100 If doesn't input the unit, the default was Mega. Limite Rate : 64K…
1.3.6.1.4.1.4756.20.481.40.1.14Columnf1000EASX2FFiber1EgressRateRemoteAread-writecurrentRemoteA device card fiber 1 Egress Rate Limit: 0 = Unlimit input format: 64k(K),100m(M),100 If doesn't input the unit, the default was Mega. Limite Rate : 64K …
1.3.6.1.4.1.4756.20.481.40.1.15Columnf1000EASX2FFiber2LinkRemoteAread-onlycurrentRemoteA device card fiber port 2 link status: 0:Down 1:Up
1.3.6.1.4.1.4756.20.481.40.1.16Columnf1000EASX2FFiber2OAMLoopedRemoteAread-onlycurrentRemoteA device card fiber port 2 OAM looped: 0:Off 1:on
1.3.6.1.4.1.4756.20.481.40.1.17Columnf1000EASX2FFiber2LBTestRemoteAread-writecurrentForce remote device card to do fiber port 2 LoopBack testing: 0:Off 1:Action
1.3.6.1.4.1.4756.20.481.40.1.18Columnf1000EASX2FFiber2OAMRLBStatusRemoteAread-onlycurrentRemote device card fiber port 1 LoopBack testing status: 0:Off 1:Ok 2:Fail
1.3.6.1.4.1.4756.20.481.40.1.19Columnf1000EASX2FFiber2RemoPwrAbRemoteAread-onlycurrentRemoteA device card fiber port 2 Remote Power status: 0:Abnormal 1:OK 2:None
1.3.6.1.4.1.4756.20.481.40.1.20Columnf1000EASX2FFiber2IngressRateRemoteAread-writecurrentRemoteA device card fiber 2 Ingress Rate Limit: 0 = Unlimit input format: 64k(K),100m(M),100 If doesn't input the unit, the default was Mega. Limite Rate : 64K…
1.3.6.1.4.1.4756.20.481.40.1.21Columnf1000EASX2FFiber2EgressRateRemoteAread-writecurrentRemoteA device card fiber 2 Egress Rate Limit: 0 = Unlimit input format: 64k(K),100m(M),100 If doesn't input the unit, the default was Mega. Limite Rate : 64K …
1.3.6.1.4.1.4756.20.481.40.1.22Columnf1000EASX2FFiber1FEFRemoteAread-onlycurrentRemoteA device card fiber1 port FEF status: 0:Off 1:Detected
1.3.6.1.4.1.4756.20.481.40.1.23Columnf1000EASX2FFiber2FEFRemoteAread-onlycurrentRemoteA device card fiber2 port FEF status: 0:Off 1:Detected
1.3.6.1.4.1.4756.20.481.40.1.24Columnf1000EASX2FDeviceActiveRemoteAread-onlycurrentRemoteA device card active mode: (It is read-only in local device.) 0:Disable 1:Enable
1.3.6.1.4.1.4756.20.481.40.1.25Columnf1000EASX2FDeviceResetRemoteAread-writecurrentForce local device card to reset mode: 0:Off 1:Action
1.3.6.1.4.1.4756.20.481.40.1.26Columnf1000EASX2FFiber1ActiveRemoteAread-writecurrentRemoteA device fiber port 1 active mode: 0:Disable 1:Enable
1.3.6.1.4.1.4756.20.481.40.1.27Columnf1000EASX2FFiber2ActiveRemoteAread-writecurrentRemoteA device fiber port 2 active mode: 0:Disable 1:Enable
1.3.6.1.4.1.4756.20.481.40.1.28Columnf1000EASX2FOamChAModeRemoteAread-writecurrentRemoteA device OAM Channel A mode: 0:Disable 1:passive 2:Active
1.3.6.1.4.1.4756.20.481.40.1.29Columnf1000EASX2FOamChBModeRemoteAread-writecurrentRemoteA device OAM Channel B mode: 0:Disable 1:passive 2:Active
1.3.6.1.4.1.4756.20.481.40.1.30Columnf1000EASX2FOamMaxPDUsRemoteAread-writecurrentRemoteA device OAM max OAMPDU size: 60-1518 Octets
1.3.6.1.4.1.4756.20.481.40.1.31Columnf1000EASX2FFiber1AlsRemoteAread-writecurrentRemoteA device card port 1 Auto Laser Shutdown mode: 0:Disable 1:Enable
1.3.6.1.4.1.4756.20.481.40.1.32Columnf1000EASX2FFiber2AlsRemoteAread-writecurrentRemoteA device card port 2 Auto Laser Shutdown mode: 0:Disable 1:Enable
1.3.6.1.4.1.4756.20.481.40.1.33Columnf1000EASX2FPauseFrameRemoteAread-writecurrentRemoteA device card pause frame mode: 0:Disable 1:Enable
1.3.6.1.4.1.4756.20.481.40.1.34Columnf1000EASX2FSendFHRtoARemoteAread-writecurrentRemoteA device card port 1 send Fiber Hardware Reset to remote: 0:No action 1:Action
1.3.6.1.4.1.4756.20.481.40.1.35Columnf1000EASX2FSendFHRtoBRemoteAread-writecurrentRemoteA device card port 2 send Fiber Hardware Reset to remote: 0:No action 1:Action
1.3.6.1.4.1.4756.20.481.40.1.36Columnf1000EASX2FFiber1LLFDepPort2RemoteAread-writecurrentRemoteA device card port 1 Link Loss Forwarding depends on port 2 Fiber Rx link: 0:don't care 1:selected
1.3.6.1.4.1.4756.20.481.40.1.37Columnf1000EASX2FFiber2LLFDepPort1RemoteAread-writecurrentRemoteA device card port 2 Link Loss Forwarding depends on port 1 Fiber Rx link: 0:don't care 1:selected
1.3.6.1.4.1.4756.20.481.40.1.38Columnf1000EASX2FAdvanceFunsRemoteAread-writecurrentRemoteA device card Switch functions mode: 0:Normal 5:Static 802.1Q VLAN 6:Spanning Tree Protocol 7:802.1Q VLAN Trunk 9:Q in Q VLAN 11:Spanning Tree Protocol a…
1.3.6.1.4.1.4756.20.481.40.1.39Columnf1000EASX2FFiber1InfoROM1RemoteAread-onlycurrentRemoteA device card port 1 INFORemoteOM information 1 valid: 0:Invalid 1:Valid
1.3.6.1.4.1.4756.20.481.40.1.40Columnf1000EASX2FFiber1InfoROM2RemoteAread-onlycurrentRemoteA device card port 1 INFORemoteOM information 2 valid: 0:Invalid 1:Valid(replacing D/D function
1.3.6.1.4.1.4756.20.481.40.1.41Columnf1000EASX2FFiber2InfoROM1RemoteAread-onlycurrentRemoteA device card port 2 INFORemoteOM information 1 valid: 0:Invalid 1:Valid
1.3.6.1.4.1.4756.20.481.40.1.42Columnf1000EASX2FFiber2InfoROM2RemoteAread-onlycurrentRemoteA device card port 2 INFORemoteOM information 2 valid: 0:Invalid 1:Valid(replacing D/D function)
1.3.6.1.4.1.4756.20.481.40.1.43Columnf1000EASX2FFiber1InfoSN1RemoteAread-onlycurrentRemoteA device card port 1 INFORemoteOM S/N 1
1.3.6.1.4.1.4756.20.481.40.1.44Columnf1000EASX2FFiber1InfoSN2RemoteAread-onlycurrentRemoteA device card port 1 INFORemoteOM S/N 2
1.3.6.1.4.1.4756.20.481.40.1.45Columnf1000EASX2FFiber2InfoSN1RemoteAread-onlycurrentRemoteA device card port 2 INFORemoteOM S/N 1
1.3.6.1.4.1.4756.20.481.40.1.46Columnf1000EASX2FFiber2InfoSN2RemoteAread-onlycurrentRemoteA device card port 2 INFORemoteOM S/N 2
1.3.6.1.4.1.4756.20.481.40.1.47Columnf1000EASX2FFiber1DDRemoteAread-onlycurrentRemoteA device card fiber port 1 Digital Diagnostic function: 0:No 1:Yes
1.3.6.1.4.1.4756.20.481.40.1.48Columnf1000EASX2FFiber1DDVendorRemoteAread-onlycurrentRemoteA device card fiber port 1 D/D information: Vendor name
1.3.6.1.4.1.4756.20.481.40.1.49Columnf1000EASX2FFiber1DDPartNoRemoteAread-onlycurrentRemoteA device card fiber port 1 D/D information: Vendor part number
1.3.6.1.4.1.4756.20.481.40.1.50Columnf1000EASX2FFiber1DDFiberTypeRemoteAread-onlycurrentRemoteA device card fiber port 1 D/D information: Fiber Type
1.3.6.1.4.1.4756.20.481.40.1.51Columnf1000EASX2FFiber1DDWaveLenRemoteAread-onlycurrentRemoteA device card fiber port 1 D/D information: Wave length
1.3.6.1.4.1.4756.20.481.40.1.52Columnf1000EASX2FFiber1DDWaveLen2RemoteAread-onlycurrentRemoteA device card fiber port 1 D/D information: Wave length 2
1.3.6.1.4.1.4756.20.481.40.1.53Columnf1000EASX2FFiber1DDLinkLenRemoteAread-onlycurrentRemoteA device card fiber port 1 D/D information: Link length
1.3.6.1.4.1.4756.20.481.40.1.54Columnf1000EASX2FFiber1DDLenUnitRemoteAread-onlycurrentRemoteA device card fiber port 1 D/D information: Length Unit
1.3.6.1.4.1.4756.20.481.40.1.55Columnf1000EASX2FFiber1DDStatusRemoteAread-onlycurrentRemoteA device card fiber port 1 D/D information: Status Support
1.3.6.1.4.1.4756.20.481.40.1.56Columnf1000EASX2FFiber1DDRxSensRemoteAread-onlycurrentRemoteA device card fiber port 1 D/D information: Rx Sensitivity
1.3.6.1.4.1.4756.20.481.40.1.57Columnf1000EASX2FFiber1DDTxPWRRemoteAread-onlycurrentRemoteA device card fiber port 1 D/D information: Tx power
1.3.6.1.4.1.4756.20.481.40.1.58Columnf1000EASX2FFiber1DDRxPWRRemoteAread-onlycurrentRemoteA device card fiber port 1 D/D information: Rx power
1.3.6.1.4.1.4756.20.481.40.1.59Columnf1000EASX2FFiber1DDTempRemoteAread-onlycurrentRemoteA device card fiber port 1 D/D information: Temperature in degree C
1.3.6.1.4.1.4756.20.481.40.1.60Columnf1000EASX2FFiber1DDPWRMarginRemoteAread-onlycurrentRemoteA device card fiber port 1 D/D information: Power margin
1.3.6.1.4.1.4756.20.481.40.1.61Columnf1000EASX2FFiber1DDPWRLossRemoteAread-onlycurrentRemoteA device card fiber port 1 D/D information: Power loss
1.3.6.1.4.1.4756.20.481.40.1.62Columnf1000EASX2FFiber2DDRemoteAread-onlycurrentRemoteA device card fiber port 2 Digital Diagnostic function: 0:No 1:Yes
1.3.6.1.4.1.4756.20.481.40.1.63Columnf1000EASX2FFiber2DDVendorRemoteAread-onlycurrentRemoteA device card fiber port 2 D/D information: Vendor name
1.3.6.1.4.1.4756.20.481.40.1.64Columnf1000EASX2FFiber2DDPartNoRemoteAread-onlycurrentRemoteA device card fiber port 2 D/D information: Vendor part number
1.3.6.1.4.1.4756.20.481.40.1.65Columnf1000EASX2FFiber2DDFiberTypeRemoteAread-onlycurrentRemoteA device card fiber port 2 D/D information: Fiber Type
1.3.6.1.4.1.4756.20.481.40.1.66Columnf1000EASX2FFiber2DDWaveLenRemoteAread-onlycurrentRemoteA device card fiber port 2 D/D information: Wave length
1.3.6.1.4.1.4756.20.481.40.1.67Columnf1000EASX2FFiber2DDWaveLen2RemoteAread-onlycurrentRemoteA device card fiber port 2 D/D information: Wave length 2
1.3.6.1.4.1.4756.20.481.40.1.68Columnf1000EASX2FFiber2DDLinkLenRemoteAread-onlycurrentRemoteA device card fiber port 2 D/D information: Link length
1.3.6.1.4.1.4756.20.481.40.1.69Columnf1000EASX2FFiber2DDLenUnitRemoteAread-onlycurrentRemoteA device card fiber port 2 D/D information: Length Unit
1.3.6.1.4.1.4756.20.481.40.1.70Columnf1000EASX2FFiber2DDStatusRemoteAread-onlycurrentRemoteA device card fiber port 2 D/D information: Status Support
1.3.6.1.4.1.4756.20.481.40.1.71Columnf1000EASX2FFiber2DDRxSensRemoteAread-onlycurrentRemoteA device card fiber port 2 D/D information: Rx Sensitivity
1.3.6.1.4.1.4756.20.481.40.1.72Columnf1000EASX2FFiber2DDTxPWRRemoteAread-onlycurrentRemoteA device card fiber port 2 D/D information: Tx power
1.3.6.1.4.1.4756.20.481.40.1.73Columnf1000EASX2FFiber2DDRxPWRRemoteAread-onlycurrentRemoteA device card fiber port 2 D/D information: Rx power
1.3.6.1.4.1.4756.20.481.40.1.74Columnf1000EASX2FFiber2DDTempRemoteAread-onlycurrentRemoteA device card fiber port 2 D/D information: Temperature in degree C
1.3.6.1.4.1.4756.20.481.40.1.75Columnf1000EASX2FFiber2DDPWRMarginRemoteAread-onlycurrentRemoteA device card fiber port 2 D/D information: Power margin
1.3.6.1.4.1.4756.20.481.40.1.76Columnf1000EASX2FFiber2DDPWRLossRemoteAread-onlycurrentRemoteA device card fiber port 2 D/D information: Power loss
1.3.6.1.4.1.4756.20.481.40.1.77Columnf1000EASX2FClrRMONCntsRemoteAread-writecurrentClear local device card RMON IN/OUT counters: 0:No action 1:Action
1.3.6.1.4.1.4756.20.481.40.1.78Columnf1000EASX2FFiber1RMONInRemoteAread-onlycurrentRemoteA device card port 1 RMON IN counter.
1.3.6.1.4.1.4756.20.481.40.1.79Columnf1000EASX2FFiber1RMONOutRemoteAread-onlycurrentRemoteA device card port 1 RMON OUT counter.
1.3.6.1.4.1.4756.20.481.40.1.80Columnf1000EASX2FFiber2RMONInRemoteAread-onlycurrentRemoteA device card port 2 RMON IN counter.
1.3.6.1.4.1.4756.20.481.40.1.81Columnf1000EASX2FFiber2RMONOutRemoteAread-onlycurrentRemoteA device card port 2 RMON OUT counter.
1.3.6.1.4.1.4756.20.481.40.1.82Columnf1000EASX2FClrOAMCntsRemoteAread-writecurrentClear local device card OAM counters: 0:No action 1:Action
1.3.6.1.4.1.4756.20.481.40.1.83Columnf1000EASX2FIpModeRemoteAread-writecurrentOn Rack Ip Mode: 0:Enable 1:Disable
1.3.6.1.4.1.4756.20.481.40.1.84Columnf1000EASX2FOamChATxRemoteAread-onlycurrentRemoteA device OAM Channel A TX OAMPDU frame count
1.3.6.1.4.1.4756.20.481.40.1.85Columnf1000EASX2FOamChARxRemoteAread-onlycurrentRemoteA device OAM Channel A RX OAMPDU frame count
1.3.6.1.4.1.4756.20.481.40.1.86Columnf1000EASX2FOamInfoChATxRemoteAread-onlycurrentRemoteA device OAM Channel A TX Information OAMPDU frame count
1.3.6.1.4.1.4756.20.481.40.1.87Columnf1000EASX2FOamInfoChARxRemoteAread-onlycurrentRemoteA device OAM Channel A RX Information OAMPDU frame count
1.3.6.1.4.1.4756.20.481.40.1.88Columnf1000EASX2FOamEventChATxRemoteAread-onlycurrentRemoteA device OAM Channel A TX Event OAMPDU frame count
1.3.6.1.4.1.4756.20.481.40.1.89Columnf1000EASX2FOamUniEvtChARxRemoteAread-onlycurrentRemoteA device OAM Channel A RX Unique Event OAMPDU frame count
1.3.6.1.4.1.4756.20.481.40.1.90Columnf1000EASX2FOamDupEvtChARxRemoteAread-onlycurrentRemoteA device OAM Channel A RX Duplicate Event OAMPDU frame count
1.3.6.1.4.1.4756.20.481.40.1.91Columnf1000EASX2FOamLbChATxRemoteAread-onlycurrentRemoteA device OAM Channel A TX Loopback Control OAMPDU frame count
1.3.6.1.4.1.4756.20.481.40.1.92Columnf1000EASX2FOamLbChARxRemoteAread-onlycurrentRemoteA device OAM Channel A RX Loopback Control OAMPDU frame count
1.3.6.1.4.1.4756.20.481.40.1.93Columnf1000EASX2FOamVarReqChATxRemoteAread-onlycurrentRemoteA device OAM Channel A TX Variable Request OAMPDU frame count
1.3.6.1.4.1.4756.20.481.40.1.94Columnf1000EASX2FOamVarReqChARxRemoteAread-onlycurrentRemoteA device OAM Channel A RX Variable Request OAMPDU frame count
1.3.6.1.4.1.4756.20.481.40.1.95Columnf1000EASX2FOamVarRspChATxRemoteAread-onlycurrentRemoteA device OAM Channel A TX Variable Response OAMPDU frame count
1.3.6.1.4.1.4756.20.481.40.1.96Columnf1000EASX2FOamVarRspChARxRemoteAread-onlycurrentRemoteA device OAM Channel A RX Variable Response OAMPDU frame count
1.3.6.1.4.1.4756.20.481.40.1.97Columnf1000EASX2FOamOuiChATxRemoteAread-onlycurrentRemoteA device OAM Channel A TX OUI OAMPDU frame count
1.3.6.1.4.1.4756.20.481.40.1.98Columnf1000EASX2FOamOuiChARxRemoteAread-onlycurrentRemoteA device OAM Channel A RX OUI OAMPDU frame count
1.3.6.1.4.1.4756.20.481.40.1.99Columnf1000EASX2FOamUnknowChARxRemoteAread-onlycurrentRemoteA device OAM Channel A RX Unsupported OAMPDU frame count
1.3.6.1.4.1.4756.20.481.40.1.100Columnf1000EASX2FOamChBTxRemoteAread-onlycurrentRemoteA device OAM Channel B TX OAMPDU frame count
1.3.6.1.4.1.4756.20.481.40.1.101Columnf1000EASX2FOamChBRxRemoteAread-onlycurrentRemoteA device OAM Channel B RX OAMPDU frame count
1.3.6.1.4.1.4756.20.481.40.1.102Columnf1000EASX2FOamInfoChBTxRemoteAread-onlycurrentRemoteA device OAM Channel B TX Information OAMPDU frame count
1.3.6.1.4.1.4756.20.481.40.1.103Columnf1000EASX2FOamInfoChBRxRemoteAread-onlycurrentRemoteA device OAM Channel B RX Information OAMPDU frame count
1.3.6.1.4.1.4756.20.481.40.1.104Columnf1000EASX2FOamEventChBTxRemoteAread-onlycurrentRemoteA device OAM Channel B TX Event OAMPDU frame count
1.3.6.1.4.1.4756.20.481.40.1.105Columnf1000EASX2FOamUniEvtChBRxRemoteAread-onlycurrentRemoteA device OAM Channel B RX Unique Event OAMPDU frame count
1.3.6.1.4.1.4756.20.481.40.1.106Columnf1000EASX2FOamDupEvtChBRxRemoteAread-onlycurrentRemoteA device OAM Channel B RX Duplicate Event OAMPDU frame count
1.3.6.1.4.1.4756.20.481.40.1.107Columnf1000EASX2FOamLbChBTxRemoteAread-onlycurrentRemoteA device OAM Channel B TX Loopback Control OAMPDU frame count
1.3.6.1.4.1.4756.20.481.40.1.108Columnf1000EASX2FOamLbChBRxRemoteAread-onlycurrentRemoteA device OAM Channel B RX Loopback Control OAMPDU frame count
1.3.6.1.4.1.4756.20.481.40.1.109Columnf1000EASX2FOamVarReqChBTxRemoteAread-onlycurrentRemoteA device OAM Channel B TX Variable Request OAMPDU frame count
1.3.6.1.4.1.4756.20.481.40.1.110Columnf1000EASX2FOamVarReqChBRxRemoteAread-onlycurrentRemoteA device OAM Channel B RX Variable Request OAMPDU frame count
1.3.6.1.4.1.4756.20.481.40.1.111Columnf1000EASX2FOamVarRspChBTxRemoteAread-onlycurrentRemoteA device OAM Channel B TX Variable Response OAMPDU frame count
1.3.6.1.4.1.4756.20.481.40.1.112Columnf1000EASX2FOamVarRspChBRxRemoteAread-onlycurrentRemoteA device OAM Channel B RX Variable Response OAMPDU frame count
1.3.6.1.4.1.4756.20.481.40.1.113Columnf1000EASX2FOamOuiChBTxRemoteAread-onlycurrentRemoteA device OAM Channel B TX OUI OAMPDU frame count
1.3.6.1.4.1.4756.20.481.40.1.114Columnf1000EASX2FOamOuiChBRxRemoteAread-onlycurrentRemoteA device OAM Channel B RX OUI OAMPDU frame count
1.3.6.1.4.1.4756.20.481.40.1.115Columnf1000EASX2FOamUnknowChBRxRemoteAread-onlycurrentRemoteA device OAM Channel B RX Unsupported OAMPDU frame count
1.3.6.1.4.1.4756.20.481.40.1.116Columnf1000EASX2FFiber1SpeedRemoteAread-onlycurrentRemoteA device Fiber 1 speed : 0:1000Auto 1:1000FDX 2:100FDX
1.3.6.1.4.1.4756.20.481.40.1.117Columnf1000EASX2FFiber2SpeedRemoteAread-onlycurrentRemoteA device Fiber 2 speed : 0:1000Auto 1:1000FDX 2:100FDX
1.3.6.1.4.1.4756.20.481.40.1.118Columnf1000EASX2FMacLearningRemoteAread-writecurrentRemoteA device Mac learning : 0:Disable 1:Enable
1.3.6.1.4.1.4756.20.481.40.1.119Columnf1000EASX2FManagementVIDRemoteAread-writecurrentRemoteA device Management VID :
1.3.6.1.4.1.4756.20.481.40.1.120Columnf1000EASX2FTagTypeRemoteAread-writecurrentRemoteA device Tag Type (HEX) :
1.3.6.1.4.1.4756.20.481.40.1.121Columnf1000EASX2FPort1VIDRemoteAread-writecurrentRemoteA device Port 1 VID :
1.3.6.1.4.1.4756.20.481.40.1.122Columnf1000EASX2FPort2VIDRemoteAread-writecurrentRemoteA device Port 2 VID :
1.3.6.1.4.1.4756.20.481.40.1.123Columnf1000EASX2FPort1QinQRemoteAread-writecurrentRemoteA device Port 1 Q in Q Support : 1:Disable 2:Enable
1.3.6.1.4.1.4756.20.481.40.1.124Columnf1000EASX2FPort2QinQRemoteAread-writecurrentRemoteA device Port 2 Q in Q Support : 1:Disable 2:Enable
1.3.6.1.4.1.4756.20.481.40.1.125Columnf1000EASX2FVID1RemoteAread-writecurrentRemoteA device VID 1:
1.3.6.1.4.1.4756.20.481.40.1.126Columnf1000EASX2FVID2RemoteAread-writecurrentRemoteA device VID 2:
1.3.6.1.4.1.4756.20.481.40.1.127Columnf1000EASX2FVID3RemoteAread-writecurrentRemoteA device VID 3:
1.3.6.1.4.1.4756.20.481.40.1.128Columnf1000EASX2FVID4RemoteAread-writecurrentRemoteA device VID 4:
1.3.6.1.4.1.4756.20.481.40.1.129Columnf1000EASX2FVID5RemoteAread-writecurrentRemoteA device VID 5:
1.3.6.1.4.1.4756.20.481.40.1.130Columnf1000EASX2FVID6RemoteAread-writecurrentRemoteA device VID 6:
1.3.6.1.4.1.4756.20.481.40.1.131Columnf1000EASX2FVID7RemoteAread-writecurrentRemoteA device VID 7:
1.3.6.1.4.1.4756.20.481.40.1.132Columnf1000EASX2FVID8RemoteAread-writecurrentRemoteA device VID 8:
1.3.6.1.4.1.4756.20.481.40.1.133Columnf1000EASX2FVID9RemoteAread-writecurrentRemoteA device VID 9:
1.3.6.1.4.1.4756.20.481.40.1.134Columnf1000EASX2FVID10RemoteAread-writecurrentRemoteA device VID 10:
1.3.6.1.4.1.4756.20.481.40.1.135Columnf1000EASX2FVID11RemoteAread-writecurrentRemoteA device VID 11:
1.3.6.1.4.1.4756.20.481.40.1.136Columnf1000EASX2FVID12RemoteAread-writecurrentRemoteA device VID 12:
1.3.6.1.4.1.4756.20.481.40.1.137Columnf1000EASX2FVID13RemoteAread-writecurrentRemoteA device VID 13:
1.3.6.1.4.1.4756.20.481.40.1.138Columnf1000EASX2FVID14RemoteAread-writecurrentRemoteA device VID 14:
1.3.6.1.4.1.4756.20.481.40.1.139Columnf1000EASX2FVID15RemoteAread-writecurrentRemoteA device VID 15:
1.3.6.1.4.1.4756.20.481.40.1.140Columnf1000EASX2FVID16RemoteAread-writecurrentRemoteA device VID 16:
1.3.6.1.4.1.4756.20.481.40.1.141Columnf1000EASX2FPort1Member1RemoteAread-writecurrentRemoteA device card port 1 member: 0:Unmodify 1:Untagged 2:Tagged 3:Nonmember
1.3.6.1.4.1.4756.20.481.40.1.142Columnf1000EASX2FPort1Member2RemoteAread-writecurrentRemoteA device card port 1 member 2: 0:Unmodify 1:Untagged 2:Tagged 3:Nonmember
1.3.6.1.4.1.4756.20.481.40.1.143Columnf1000EASX2FPort1Member3RemoteAread-writecurrentRemoteA device card port 1 member 3: 0:Unmodify 1:Untagged 2:Tagged 3:Nonmember
1.3.6.1.4.1.4756.20.481.40.1.144Columnf1000EASX2FPort1Member4RemoteAread-writecurrentRemoteA device card port 1 member 4: 0:Unmodify 1:Untagged 2:Tagged 3:Nonmember
1.3.6.1.4.1.4756.20.481.40.1.145Columnf1000EASX2FPort1Member5RemoteAread-writecurrentRemoteA device card port 1 member 5: 0:Unmodify 1:Untagged 2:Tagged 3:Nonmember
1.3.6.1.4.1.4756.20.481.40.1.146Columnf1000EASX2FPort1Member6RemoteAread-writecurrentRemoteA device card port 1 member 6: 0:Unmodify 1:Untagged 2:Tagged 3:Nonmember
1.3.6.1.4.1.4756.20.481.40.1.147Columnf1000EASX2FPort1Member7RemoteAread-writecurrentRemoteA device card port 1 member 7: 0:Unmodify 1:Untagged 2:Tagged 3:Nonmember
1.3.6.1.4.1.4756.20.481.40.1.148Columnf1000EASX2FPort1Member8RemoteAread-writecurrentRemoteA device card port 1 member 8: 0:Unmodify 1:Untagged 2:Tagged 3:Nonmember
1.3.6.1.4.1.4756.20.481.40.1.149Columnf1000EASX2FPort1Member9RemoteAread-writecurrentRemoteA device card port 1 member 9: 0:Unmodify 1:Untagged 2:Tagged 3:Nonmember
1.3.6.1.4.1.4756.20.481.40.1.150Columnf1000EASX2FPort1Member10RemoteAread-writecurrentRemoteA device card port 1 member 10: 0:Unmodify 1:Untagged 2:Tagged 3:Nonmember
1.3.6.1.4.1.4756.20.481.40.1.151Columnf1000EASX2FPort1Member11RemoteAread-writecurrentRemoteA device card port 1 member 11: 0:Unmodify 1:Untagged 2:Tagged 3:Nonmember
1.3.6.1.4.1.4756.20.481.40.1.152Columnf1000EASX2FPort1Member12RemoteAread-writecurrentRemoteA device card port 1 member 12: 0:Unmodify 1:Untagged 2:Tagged 3:Nonmember
1.3.6.1.4.1.4756.20.481.40.1.153Columnf1000EASX2FPort1Member13RemoteAread-writecurrentRemoteA device card port 1 member 13: 0:Unmodify 1:Untagged 2:Tagged 3:Nonmember
1.3.6.1.4.1.4756.20.481.40.1.154Columnf1000EASX2FPort1Member14RemoteAread-writecurrentRemoteA device card port 1 member 14: 0:Unmodify 1:Untagged 2:Tagged 3:Nonmember
1.3.6.1.4.1.4756.20.481.40.1.155Columnf1000EASX2FPort1Member15RemoteAread-writecurrentRemoteA device card port 1 member 15: 0:Unmodify 1:Untagged 2:Tagged 3:Nonmember
1.3.6.1.4.1.4756.20.481.40.1.156Columnf1000EASX2FPort1Member16RemoteAread-writecurrentRemoteA device card port 1 member 16: 0:Unmodify 1:Untagged 2:Tagged 3:Nonmember
1.3.6.1.4.1.4756.20.481.40.1.157Columnf1000EASX2FPort2Member1RemoteAread-writecurrentRemoteA device card port 2 member: 0:Unmodify 1:Untagged 2:Tagged 3:Nonmember
1.3.6.1.4.1.4756.20.481.40.1.158Columnf1000EASX2FPort2Member2RemoteAread-writecurrentRemoteA device card port 2 member 2: 0:Unmodify 1:Untagged 2:Tagged 3:Nonmember
1.3.6.1.4.1.4756.20.481.40.1.159Columnf1000EASX2FPort2Member3RemoteAread-writecurrentRemoteA device card port 2 member 3: 0:Unmodify 1:Untagged 2:Tagged 3:Nonmember
1.3.6.1.4.1.4756.20.481.40.1.160Columnf1000EASX2FPort2Member4RemoteAread-writecurrentRemoteA device card port 2 member 4: 0:Unmodify 1:Untagged 2:Tagged 3:Nonmember
1.3.6.1.4.1.4756.20.481.40.1.161Columnf1000EASX2FPort2Member5RemoteAread-writecurrentRemoteA device card port 2 member 5: 0:Unmodify 1:Untagged 2:Tagged 3:Nonmember
1.3.6.1.4.1.4756.20.481.40.1.162Columnf1000EASX2FPort2Member6RemoteAread-writecurrentRemoteA device card port 2 member 6: 0:Unmodify 1:Untagged 2:Tagged 3:Nonmember
1.3.6.1.4.1.4756.20.481.40.1.163Columnf1000EASX2FPort2Member7RemoteAread-writecurrentRemoteA device card port 2 member 7: 0:Unmodify 1:Untagged 2:Tagged 3:Nonmember
1.3.6.1.4.1.4756.20.481.40.1.164Columnf1000EASX2FPort2Member8RemoteAread-writecurrentRemoteA device card port 2 member 8: 0:Unmodify 1:Untagged 2:Tagged 3:Nonmember
1.3.6.1.4.1.4756.20.481.40.1.165Columnf1000EASX2FPort2Member9RemoteAread-writecurrentRemoteA device card port 2 member 9: 0:Unmodify 1:Untagged 2:Tagged 3:Nonmember
1.3.6.1.4.1.4756.20.481.40.1.166Columnf1000EASX2FPort2Member10RemoteAread-writecurrentRemoteA device card port 2 member 10: 0:Unmodify 1:Untagged 2:Tagged 3:Nonmember
1.3.6.1.4.1.4756.20.481.40.1.167Columnf1000EASX2FPort2Member11RemoteAread-writecurrentRemoteA device card port 2 member 11: 0:Unmodify 1:Untagged 2:Tagged 3:Nonmember
1.3.6.1.4.1.4756.20.481.40.1.168Columnf1000EASX2FPort2Member12RemoteAread-writecurrentRemoteA device card port 2 member 12: 0:Unmodify 1:Untagged 2:Tagged 3:Nonmember
1.3.6.1.4.1.4756.20.481.40.1.169Columnf1000EASX2FPort2Member13RemoteAread-writecurrentRemoteA device card port 2 member 13: 0:Unmodify 1:Untagged 2:Tagged 3:Nonmember
1.3.6.1.4.1.4756.20.481.40.1.170Columnf1000EASX2FPort2Member14RemoteAread-writecurrentRemoteA device card port 2 member 14: 0:Unmodify 1:Untagged 2:Tagged 3:Nonmember
1.3.6.1.4.1.4756.20.481.40.1.171Columnf1000EASX2FPort2Member15RemoteAread-writecurrentRemoteA device card port 2 member 15: 0:Unmodify 1:Untagged 2:Tagged 3:Nonmember
1.3.6.1.4.1.4756.20.481.40.1.172Columnf1000EASX2FPort2Member16RemoteAread-writecurrentRemoteA device card port 2 member 16: 0:Unmodify 1:Untagged 2:Tagged 3:Nonmember
1.3.6.1.4.1.4756.20.481.40.1.173Columnf1000EASX2FIpAddressRemoteAread-writecurrentRemoteA device IP address
1.3.6.1.4.1.4756.20.481.40.1.174Columnf1000EASX2FNetMaskRemoteAread-writecurrentRemoteA device Netmask
1.3.6.1.4.1.4756.20.481.40.1.175Columnf1000EASX2FGateWayRemoteAread-writecurrentRemoteA device Gateway
1.3.6.1.4.1.4756.20.481.40.1.176Columnf1000EASX2FSetDefaultRemoteAread-writecurrentRemoteA device set to default
1.3.6.1.4.1.4756.20.481.40.1.177Columnf1000EASX2FFx1LinkAlarmRemoteAread-writecurrentRemoteA device fiber 1 link alarm 0:Disable 1:Enable
1.3.6.1.4.1.4756.20.481.40.1.178Columnf1000EASX2FFx2LinkAlarmRemoteAread-writecurrentRemoteA device fiber 2 link alarm 0:Disable 1:Enable
1.3.6.1.4.1.4756.20.481.40.1.179Columnf1000EASX2FFHRModeRemoteAread-writecurrentRemoteA device card FHR Mode: 0:Disable 1:Enable
1.3.6.1.4.1.4756.20.481.40.1.180Columnf1000EASX2FRemoteTLPTRemoteAread-writecurrentRemoteA device Remote TLPT mode : 0:Disalbe 1:Remote A 2:Remote B
1.3.6.1.4.1.4756.20.482Nodef1000EASX2FRemoteBCards
1.3.6.1.4.1.4756.20.482.40Tablef1000EASX2FRemoteBTablenot-accessiblecurrentA list of RemoteB 1000EAS/X-2F card entries.
1.3.6.1.4.1.4756.20.482.40.1Rowf1000EASX2FRemoteBEntrynot-accessiblecurrentAn entry containing management information applicable to a particular RemoteB 1000EAS/X-2F card.
1.3.6.1.4.1.4756.20.482.40.1.1Columnf1000EASX2FChassisIndexRemoteBread-onlycurrentA unique value for each chassis ID. For CH20, it is the chassis ID. For CH08, it is always 0.
1.3.6.1.4.1.4756.20.482.40.1.2Columnf1000EASX2FSlotIndexRemoteBread-onlycurrentA unique value for each local card. It is the slot location number.
1.3.6.1.4.1.4756.20.482.40.1.3Columnf1000EASX2FCardHWVerRemoteBread-onlycurrentRemoteB device card hardware version x.xxx
1.3.6.1.4.1.4756.20.482.40.1.4Columnf1000EASX2FCardFWVerRemoteBread-onlycurrentRemoteB device card firmware version x.xxx
1.3.6.1.4.1.4756.20.482.40.1.5Columnf1000EASX2FCardCPLDVerRemoteBread-onlycurrentRemoteB device card CPLD version x.xxx
1.3.6.1.4.1.4756.20.482.40.1.6Columnf1000EASX2FCardFPGAVerRemoteBread-onlycurrentRemoteB device card FPGA version x.xxx
1.3.6.1.4.1.4756.20.482.40.1.7Columnf1000EASX2FModelRemoteBread-onlycurrentRemoteB 1000EAS/X Serial Type
1.3.6.1.4.1.4756.20.482.40.1.8Columnf1000EASX2FFiber1LinkRemoteBread-onlycurrentRemoteB device card fiber port 1 link status: 0:Down 1:Up
1.3.6.1.4.1.4756.20.482.40.1.9Columnf1000EASX2FFiber1OAMLoopedRemoteBread-onlycurrentRemoteB device card fiber port 1 OAM looped: 0:Off 1:on
1.3.6.1.4.1.4756.20.482.40.1.10Columnf1000EASX2FFiber1LBTestRemoteBread-writecurrentForce remote device card to do fiber port 1 LoopBack testing: 0:Off 1:Action
1.3.6.1.4.1.4756.20.482.40.1.11Columnf1000EASX2FFiber1OAMRLBStatusRemoteBread-onlycurrentRemote device card fiber port 1 LoopBack testing status: 0:Off 1:Ok 2:Fail
1.3.6.1.4.1.4756.20.482.40.1.12Columnf1000EASX2FFiber1RemoPwrAbRemoteBread-onlycurrentRemoteB device card fiber port 1 Remote Power status: 0:Abnormal 1:OK 2:None
1.3.6.1.4.1.4756.20.482.40.1.13Columnf1000EASX2FFiber1IngressRateRemoteBread-writecurrentRemoteB device card fiber 1 Ingress Rate Limit: 0 = Unlimit input format: 64k(K),100m(M),100 If doesn't input the unit, the default was Mega. Limite Rate : 64K…
1.3.6.1.4.1.4756.20.482.40.1.14Columnf1000EASX2FFiber1EgressRateRemoteBread-writecurrentRemoteB device card fiber 1 Egress Rate Limit: 0 = Unlimit input format: 64k(K),100m(M),100 If doesn't input the unit, the default was Mega. Limite Rate : 64K …
1.3.6.1.4.1.4756.20.482.40.1.15Columnf1000EASX2FFiber2LinkRemoteBread-onlycurrentRemoteB device card fiber port 2 link status: 0:Down 1:Up
1.3.6.1.4.1.4756.20.482.40.1.16Columnf1000EASX2FFiber2OAMLoopedRemoteBread-onlycurrentRemoteB device card fiber port 2 OAM looped: 0:Off 1:on
1.3.6.1.4.1.4756.20.482.40.1.17Columnf1000EASX2FFiber2LBTestRemoteBread-writecurrentForce remote device card to do fiber port 2 LoopBack testing: 0:Off 1:Action
1.3.6.1.4.1.4756.20.482.40.1.18Columnf1000EASX2FFiber2OAMRLBStatusRemoteBread-onlycurrentRemote device card fiber port 1 LoopBack testing status: 0:Off 1:Ok 2:Fail
1.3.6.1.4.1.4756.20.482.40.1.19Columnf1000EASX2FFiber2RemoPwrAbRemoteBread-onlycurrentRemoteB device card fiber port 2 Remote Power status: 0:Abnormal 1:OK 2:None
1.3.6.1.4.1.4756.20.482.40.1.20Columnf1000EASX2FFiber2IngressRateRemoteBread-writecurrentRemoteB device card fiber 2 Ingress Rate Limit: 0 = Unlimit input format: 64k(K),100m(M),100 If doesn't input the unit, the default was Mega. Limite Rate : 64K…
1.3.6.1.4.1.4756.20.482.40.1.21Columnf1000EASX2FFiber2EgressRateRemoteBread-writecurrentRemoteB device card fiber 2 Egress Rate Limit: 0 = Unlimit input format: 64k(K),100m(M),100 If doesn't input the unit, the default was Mega. Limite Rate : 64K …
1.3.6.1.4.1.4756.20.482.40.1.22Columnf1000EASX2FFiber1FEFRemoteBread-onlycurrentRemoteB device card fiber1 port FEF status: 0:Off 1:Detected
1.3.6.1.4.1.4756.20.482.40.1.23Columnf1000EASX2FFiber2FEFRemoteBread-onlycurrentRemoteB device card fiber2 port FEF status: 0:Off 1:Detected
1.3.6.1.4.1.4756.20.482.40.1.24Columnf1000EASX2FDeviceActiveRemoteBread-onlycurrentRemoteB device card active mode: (It is read-only in local device.) 0:Disable 1:Enable
1.3.6.1.4.1.4756.20.482.40.1.25Columnf1000EASX2FDeviceResetRemoteBread-writecurrentForce local device card to reset mode: 0:Off 1:Action
1.3.6.1.4.1.4756.20.482.40.1.26Columnf1000EASX2FFiber1ActiveRemoteBread-writecurrentRemoteB device fiber port 1 active mode: 0:Disable 1:Enable
1.3.6.1.4.1.4756.20.482.40.1.27Columnf1000EASX2FFiber2ActiveRemoteBread-writecurrentRemoteB device fiber port 2 active mode: 0:Disable 1:Enable
1.3.6.1.4.1.4756.20.482.40.1.28Columnf1000EASX2FOamChAModeRemoteBread-writecurrentRemoteB device OAM Channel A mode: 0:Disable 1:passive 2:Active
1.3.6.1.4.1.4756.20.482.40.1.29Columnf1000EASX2FOamChBModeRemoteBread-writecurrentRemoteB device OAM Channel B mode: 0:Disable 1:passive 2:Active
1.3.6.1.4.1.4756.20.482.40.1.30Columnf1000EASX2FOamMaxPDUsRemoteBread-writecurrentRemoteB device OAM max OAMPDU size: 60-1518 Octets
1.3.6.1.4.1.4756.20.482.40.1.31Columnf1000EASX2FFiber1AlsRemoteBread-writecurrentRemoteB device card port 1 Auto Laser Shutdown mode: 0:Disable 1:Enable
1.3.6.1.4.1.4756.20.482.40.1.32Columnf1000EASX2FFiber2AlsRemoteBread-writecurrentRemoteB device card port 2 Auto Laser Shutdown mode: 0:Disable 1:Enable
1.3.6.1.4.1.4756.20.482.40.1.33Columnf1000EASX2FPauseFrameRemoteBread-writecurrentRemoteB device card pause frame mode: 0:Disable 1:Enable
1.3.6.1.4.1.4756.20.482.40.1.34Columnf1000EASX2FSendFHRtoARemoteBread-writecurrentRemoteB device card port 1 send Fiber Hardware Reset to remote: 0:No action 1:Action
1.3.6.1.4.1.4756.20.482.40.1.35Columnf1000EASX2FSendFHRtoBRemoteBread-writecurrentRemoteB device card port 2 send Fiber Hardware Reset to remote: 0:No action 1:Action
1.3.6.1.4.1.4756.20.482.40.1.36Columnf1000EASX2FFiber1LLFDepPort2RemoteBread-writecurrentRemoteB device card port 1 Link Loss Forwarding depends on port 2 Fiber Rx link: 0:don't care 1:selected
1.3.6.1.4.1.4756.20.482.40.1.37Columnf1000EASX2FFiber2LLFDepPort1RemoteBread-writecurrentRemoteB device card port 2 Link Loss Forwarding depends on port 1 Fiber Rx link: 0:don't care 1:selected
1.3.6.1.4.1.4756.20.482.40.1.38Columnf1000EASX2FAdvanceFunsRemoteBread-writecurrentRemoteB device card Switch functions mode: 0:Normal 5:Static 802.1Q VLAN 6:Spanning Tree Protocol 7:802.1Q VLAN Trunk 9:Q in Q VLAN 11:Spanning Tree Protocol a…
1.3.6.1.4.1.4756.20.482.40.1.39Columnf1000EASX2FFiber1InfoROM1RemoteBread-onlycurrentRemoteB device card port 1 INFORemoteOM information 1 valid: 0:Invalid 1:Valid
1.3.6.1.4.1.4756.20.482.40.1.40Columnf1000EASX2FFiber1InfoROM2RemoteBread-onlycurrentRemoteB device card port 1 INFORemoteOM information 2 valid: 0:Invalid 1:Valid(replacing D/D function
1.3.6.1.4.1.4756.20.482.40.1.41Columnf1000EASX2FFiber2InfoROM1RemoteBread-onlycurrentRemoteB device card port 2 INFORemoteOM information 1 valid: 0:Invalid 1:Valid
1.3.6.1.4.1.4756.20.482.40.1.42Columnf1000EASX2FFiber2InfoROM2RemoteBread-onlycurrentRemoteB device card port 2 INFORemoteOM information 2 valid: 0:Invalid 1:Valid(replacing D/D function)
1.3.6.1.4.1.4756.20.482.40.1.43Columnf1000EASX2FFiber1InfoSN1RemoteBread-onlycurrentRemoteB device card port 1 INFORemoteOM S/N 1
1.3.6.1.4.1.4756.20.482.40.1.44Columnf1000EASX2FFiber1InfoSN2RemoteBread-onlycurrentRemoteB device card port 1 INFORemoteOM S/N 2
1.3.6.1.4.1.4756.20.482.40.1.45Columnf1000EASX2FFiber2InfoSN1RemoteBread-onlycurrentRemoteB device card port 2 INFORemoteOM S/N 1
1.3.6.1.4.1.4756.20.482.40.1.46Columnf1000EASX2FFiber2InfoSN2RemoteBread-onlycurrentRemoteB device card port 2 INFORemoteOM S/N 2
1.3.6.1.4.1.4756.20.482.40.1.47Columnf1000EASX2FFiber1DDRemoteBread-onlycurrentRemoteB device card fiber port 1 Digital Diagnostic function: 0:No 1:Yes
1.3.6.1.4.1.4756.20.482.40.1.48Columnf1000EASX2FFiber1DDVendorRemoteBread-onlycurrentRemoteB device card fiber port 1 D/D information: Vendor name
1.3.6.1.4.1.4756.20.482.40.1.49Columnf1000EASX2FFiber1DDPartNoRemoteBread-onlycurrentRemoteB device card fiber port 1 D/D information: Vendor part number
1.3.6.1.4.1.4756.20.482.40.1.50Columnf1000EASX2FFiber1DDFiberTypeRemoteBread-onlycurrentRemoteB device card fiber port 1 D/D information: Fiber Type
1.3.6.1.4.1.4756.20.482.40.1.51Columnf1000EASX2FFiber1DDWaveLenRemoteBread-onlycurrentRemoteB device card fiber port 1 D/D information: Wave length
1.3.6.1.4.1.4756.20.482.40.1.52Columnf1000EASX2FFiber1DDWaveLen2RemoteBread-onlycurrentRemoteB device card fiber port 1 D/D information: Wave length 2
1.3.6.1.4.1.4756.20.482.40.1.53Columnf1000EASX2FFiber1DDLinkLenRemoteBread-onlycurrentRemoteB device card fiber port 1 D/D information: Link length
1.3.6.1.4.1.4756.20.482.40.1.54Columnf1000EASX2FFiber1DDLenUnitRemoteBread-onlycurrentRemoteB device card fiber port 1 D/D information: Length Unit
1.3.6.1.4.1.4756.20.482.40.1.55Columnf1000EASX2FFiber1DDStatusRemoteBread-onlycurrentRemoteB device card fiber port 1 D/D information: Status Support
1.3.6.1.4.1.4756.20.482.40.1.56Columnf1000EASX2FFiber1DDRxSensRemoteBread-onlycurrentRemoteB device card fiber port 1 D/D information: Rx Sensitivity
1.3.6.1.4.1.4756.20.482.40.1.57Columnf1000EASX2FFiber1DDTxPWRRemoteBread-onlycurrentRemoteB device card fiber port 1 D/D information: Tx power
1.3.6.1.4.1.4756.20.482.40.1.58Columnf1000EASX2FFiber1DDRxPWRRemoteBread-onlycurrentRemoteB device card fiber port 1 D/D information: Rx power
1.3.6.1.4.1.4756.20.482.40.1.59Columnf1000EASX2FFiber1DDTempRemoteBread-onlycurrentRemoteB device card fiber port 1 D/D information: Temperature in degree C
1.3.6.1.4.1.4756.20.482.40.1.60Columnf1000EASX2FFiber1DDPWRMarginRemoteBread-onlycurrentRemoteB device card fiber port 1 D/D information: Power margin
1.3.6.1.4.1.4756.20.482.40.1.61Columnf1000EASX2FFiber1DDPWRLossRemoteBread-onlycurrentRemoteB device card fiber port 1 D/D information: Power loss
1.3.6.1.4.1.4756.20.482.40.1.62Columnf1000EASX2FFiber2DDRemoteBread-onlycurrentRemoteB device card fiber port 2 Digital Diagnostic function: 0:No 1:Yes
1.3.6.1.4.1.4756.20.482.40.1.63Columnf1000EASX2FFiber2DDVendorRemoteBread-onlycurrentRemoteB device card fiber port 2 D/D information: Vendor name
1.3.6.1.4.1.4756.20.482.40.1.64Columnf1000EASX2FFiber2DDPartNoRemoteBread-onlycurrentRemoteB device card fiber port 2 D/D information: Vendor part number
1.3.6.1.4.1.4756.20.482.40.1.65Columnf1000EASX2FFiber2DDFiberTypeRemoteBread-onlycurrentRemoteB device card fiber port 2 D/D information: Fiber Type
1.3.6.1.4.1.4756.20.482.40.1.66Columnf1000EASX2FFiber2DDWaveLenRemoteBread-onlycurrentRemoteB device card fiber port 2 D/D information: Wave length
1.3.6.1.4.1.4756.20.482.40.1.67Columnf1000EASX2FFiber2DDWaveLen2RemoteBread-onlycurrentRemoteB device card fiber port 2 D/D information: Wave length 2
1.3.6.1.4.1.4756.20.482.40.1.68Columnf1000EASX2FFiber2DDLinkLenRemoteBread-onlycurrentRemoteB device card fiber port 2 D/D information: Link length
1.3.6.1.4.1.4756.20.482.40.1.69Columnf1000EASX2FFiber2DDLenUnitRemoteBread-onlycurrentRemoteB device card fiber port 2 D/D information: Length Unit
1.3.6.1.4.1.4756.20.482.40.1.70Columnf1000EASX2FFiber2DDStatusRemoteBread-onlycurrentRemoteB device card fiber port 2 D/D information: Status Support
1.3.6.1.4.1.4756.20.482.40.1.71Columnf1000EASX2FFiber2DDRxSensRemoteBread-onlycurrentRemoteB device card fiber port 2 D/D information: Rx Sensitivity
1.3.6.1.4.1.4756.20.482.40.1.72Columnf1000EASX2FFiber2DDTxPWRRemoteBread-onlycurrentRemoteB device card fiber port 2 D/D information: Tx power
1.3.6.1.4.1.4756.20.482.40.1.73Columnf1000EASX2FFiber2DDRxPWRRemoteBread-onlycurrentRemoteB device card fiber port 2 D/D information: Rx power
1.3.6.1.4.1.4756.20.482.40.1.74Columnf1000EASX2FFiber2DDTempRemoteBread-onlycurrentRemoteB device card fiber port 2 D/D information: Temperature in degree C
1.3.6.1.4.1.4756.20.482.40.1.75Columnf1000EASX2FFiber2DDPWRMarginRemoteBread-onlycurrentRemoteB device card fiber port 2 D/D information: Power margin
1.3.6.1.4.1.4756.20.482.40.1.76Columnf1000EASX2FFiber2DDPWRLossRemoteBread-onlycurrentRemoteB device card fiber port 2 D/D information: Power loss
1.3.6.1.4.1.4756.20.482.40.1.77Columnf1000EASX2FClrRMONCntsRemoteBread-writecurrentClear local device card RMON IN/OUT counters: 0:No action 1:Action
1.3.6.1.4.1.4756.20.482.40.1.78Columnf1000EASX2FFiber1RMONInRemoteBread-onlycurrentRemoteB device card port 1 RMON IN counter.
1.3.6.1.4.1.4756.20.482.40.1.79Columnf1000EASX2FFiber1RMONOutRemoteBread-onlycurrentRemoteB device card port 1 RMON OUT counter.
1.3.6.1.4.1.4756.20.482.40.1.80Columnf1000EASX2FFiber2RMONInRemoteBread-onlycurrentRemoteB device card port 2 RMON IN counter.
1.3.6.1.4.1.4756.20.482.40.1.81Columnf1000EASX2FFiber2RMONOutRemoteBread-onlycurrentRemoteB device card port 2 RMON OUT counter.
1.3.6.1.4.1.4756.20.482.40.1.82Columnf1000EASX2FClrOAMCntsRemoteBread-writecurrentClear local device card OAM counters: 0:No action 1:Action
1.3.6.1.4.1.4756.20.482.40.1.83Columnf1000EASX2FIpModeRemoteBread-writecurrentOn Rack Ip Mode: 0:Enable 1:Disable
1.3.6.1.4.1.4756.20.482.40.1.84Columnf1000EASX2FOamChATxRemoteBread-onlycurrentRemoteB device OAM Channel A TX OAMPDU frame count
1.3.6.1.4.1.4756.20.482.40.1.85Columnf1000EASX2FOamChARxRemoteBread-onlycurrentRemoteB device OAM Channel A RX OAMPDU frame count
1.3.6.1.4.1.4756.20.482.40.1.86Columnf1000EASX2FOamInfoChATxRemoteBread-onlycurrentRemoteB device OAM Channel A TX Information OAMPDU frame count
1.3.6.1.4.1.4756.20.482.40.1.87Columnf1000EASX2FOamInfoChARxRemoteBread-onlycurrentRemoteB device OAM Channel A RX Information OAMPDU frame count
1.3.6.1.4.1.4756.20.482.40.1.88Columnf1000EASX2FOamEventChATxRemoteBread-onlycurrentRemoteB device OAM Channel A TX Event OAMPDU frame count
1.3.6.1.4.1.4756.20.482.40.1.89Columnf1000EASX2FOamUniEvtChARxRemoteBread-onlycurrentRemoteB device OAM Channel A RX Unique Event OAMPDU frame count
1.3.6.1.4.1.4756.20.482.40.1.90Columnf1000EASX2FOamDupEvtChARxRemoteBread-onlycurrentRemoteB device OAM Channel A RX Duplicate Event OAMPDU frame count
1.3.6.1.4.1.4756.20.482.40.1.91Columnf1000EASX2FOamLbChATxRemoteBread-onlycurrentRemoteB device OAM Channel A TX Loopback Control OAMPDU frame count
1.3.6.1.4.1.4756.20.482.40.1.92Columnf1000EASX2FOamLbChARxRemoteBread-onlycurrentRemoteB device OAM Channel A RX Loopback Control OAMPDU frame count
1.3.6.1.4.1.4756.20.482.40.1.93Columnf1000EASX2FOamVarReqChATxRemoteBread-onlycurrentRemoteB device OAM Channel A TX Variable Request OAMPDU frame count
1.3.6.1.4.1.4756.20.482.40.1.94Columnf1000EASX2FOamVarReqChARxRemoteBread-onlycurrentRemoteB device OAM Channel A RX Variable Request OAMPDU frame count
1.3.6.1.4.1.4756.20.482.40.1.95Columnf1000EASX2FOamVarRspChATxRemoteBread-onlycurrentRemoteB device OAM Channel A TX Variable Response OAMPDU frame count
1.3.6.1.4.1.4756.20.482.40.1.96Columnf1000EASX2FOamVarRspChARxRemoteBread-onlycurrentRemoteB device OAM Channel A RX Variable Response OAMPDU frame count
1.3.6.1.4.1.4756.20.482.40.1.97Columnf1000EASX2FOamOuiChATxRemoteBread-onlycurrentRemoteB device OAM Channel A TX OUI OAMPDU frame count
1.3.6.1.4.1.4756.20.482.40.1.98Columnf1000EASX2FOamOuiChARxRemoteBread-onlycurrentRemoteB device OAM Channel A RX OUI OAMPDU frame count
1.3.6.1.4.1.4756.20.482.40.1.99Columnf1000EASX2FOamUnknowChARxRemoteBread-onlycurrentRemoteB device OAM Channel A RX Unsupported OAMPDU frame count
1.3.6.1.4.1.4756.20.482.40.1.100Columnf1000EASX2FOamChBTxRemoteBread-onlycurrentRemoteB device OAM Channel B TX OAMPDU frame count
1.3.6.1.4.1.4756.20.482.40.1.101Columnf1000EASX2FOamChBRxRemoteBread-onlycurrentRemoteB device OAM Channel B RX OAMPDU frame count
1.3.6.1.4.1.4756.20.482.40.1.102Columnf1000EASX2FOamInfoChBTxRemoteBread-onlycurrentRemoteB device OAM Channel B TX Information OAMPDU frame count
1.3.6.1.4.1.4756.20.482.40.1.103Columnf1000EASX2FOamInfoChBRxRemoteBread-onlycurrentRemoteB device OAM Channel B RX Information OAMPDU frame count
1.3.6.1.4.1.4756.20.482.40.1.104Columnf1000EASX2FOamEventChBTxRemoteBread-onlycurrentRemoteB device OAM Channel B TX Event OAMPDU frame count
1.3.6.1.4.1.4756.20.482.40.1.105Columnf1000EASX2FOamUniEvtChBRxRemoteBread-onlycurrentRemoteB device OAM Channel B RX Unique Event OAMPDU frame count
1.3.6.1.4.1.4756.20.482.40.1.106Columnf1000EASX2FOamDupEvtChBRxRemoteBread-onlycurrentRemoteB device OAM Channel B RX Duplicate Event OAMPDU frame count
1.3.6.1.4.1.4756.20.482.40.1.107Columnf1000EASX2FOamLbChBTxRemoteBread-onlycurrentRemoteB device OAM Channel B TX Loopback Control OAMPDU frame count
1.3.6.1.4.1.4756.20.482.40.1.108Columnf1000EASX2FOamLbChBRxRemoteBread-onlycurrentRemoteB device OAM Channel B RX Loopback Control OAMPDU frame count
1.3.6.1.4.1.4756.20.482.40.1.109Columnf1000EASX2FOamVarReqChBTxRemoteBread-onlycurrentRemoteB device OAM Channel B TX Variable Request OAMPDU frame count
1.3.6.1.4.1.4756.20.482.40.1.110Columnf1000EASX2FOamVarReqChBRxRemoteBread-onlycurrentRemoteB device OAM Channel B RX Variable Request OAMPDU frame count
1.3.6.1.4.1.4756.20.482.40.1.111Columnf1000EASX2FOamVarRspChBTxRemoteBread-onlycurrentRemoteB device OAM Channel B TX Variable Response OAMPDU frame count
1.3.6.1.4.1.4756.20.482.40.1.112Columnf1000EASX2FOamVarRspChBRxRemoteBread-onlycurrentRemoteB device OAM Channel B RX Variable Response OAMPDU frame count
1.3.6.1.4.1.4756.20.482.40.1.113Columnf1000EASX2FOamOuiChBTxRemoteBread-onlycurrentRemoteB device OAM Channel B TX OUI OAMPDU frame count
1.3.6.1.4.1.4756.20.482.40.1.114Columnf1000EASX2FOamOuiChBRxRemoteBread-onlycurrentRemoteB device OAM Channel B RX OUI OAMPDU frame count
1.3.6.1.4.1.4756.20.482.40.1.115Columnf1000EASX2FOamUnknowChBRxRemoteBread-onlycurrentRemoteB device OAM Channel B RX Unsupported OAMPDU frame count
1.3.6.1.4.1.4756.20.482.40.1.116Columnf1000EASX2FFiber1SpeedRemoteBread-onlycurrentRemoteB device Fiber 1 speed : 0:1000Auto 1:1000FDX 2:100FDX
1.3.6.1.4.1.4756.20.482.40.1.117Columnf1000EASX2FFiber2SpeedRemoteBread-onlycurrentRemoteB device Fiber 2 speed : 0:1000Auto 1:1000FDX 2:100FDX
1.3.6.1.4.1.4756.20.482.40.1.118Columnf1000EASX2FMacLearningRemoteBread-writecurrentRemoteB device Mac learning : 0:Disable 1:Enable
1.3.6.1.4.1.4756.20.482.40.1.119Columnf1000EASX2FManagementVIDRemoteBread-writecurrentRemoteB device Management VID :
1.3.6.1.4.1.4756.20.482.40.1.120Columnf1000EASX2FTagTypeRemoteBread-writecurrentRemoteB device Tag Type (HEX) :
1.3.6.1.4.1.4756.20.482.40.1.121Columnf1000EASX2FPort1VIDRemoteBread-writecurrentRemoteB device Port 1 VID :
1.3.6.1.4.1.4756.20.482.40.1.122Columnf1000EASX2FPort2VIDRemoteBread-writecurrentRemoteB device Port 2 VID :
1.3.6.1.4.1.4756.20.482.40.1.123Columnf1000EASX2FPort1QinQRemoteBread-writecurrentRemoteB device Port 1 Q in Q Support : 1:Disable 2:Enable
1.3.6.1.4.1.4756.20.482.40.1.124Columnf1000EASX2FPort2QinQRemoteBread-writecurrentRemoteB device Port 2 Q in Q Support : 1:Disable 2:Enable
1.3.6.1.4.1.4756.20.482.40.1.125Columnf1000EASX2FVID1RemoteBread-writecurrentRemoteB device VID 1:
1.3.6.1.4.1.4756.20.482.40.1.126Columnf1000EASX2FVID2RemoteBread-writecurrentRemoteB device VID 2:
1.3.6.1.4.1.4756.20.482.40.1.127Columnf1000EASX2FVID3RemoteBread-writecurrentRemoteB device VID 3:
1.3.6.1.4.1.4756.20.482.40.1.128Columnf1000EASX2FVID4RemoteBread-writecurrentRemoteB device VID 4:
1.3.6.1.4.1.4756.20.482.40.1.129Columnf1000EASX2FVID5RemoteBread-writecurrentRemoteB device VID 5:
1.3.6.1.4.1.4756.20.482.40.1.130Columnf1000EASX2FVID6RemoteBread-writecurrentRemoteB device VID 6:
1.3.6.1.4.1.4756.20.482.40.1.131Columnf1000EASX2FVID7RemoteBread-writecurrentRemoteB device VID 7:
1.3.6.1.4.1.4756.20.482.40.1.132Columnf1000EASX2FVID8RemoteBread-writecurrentRemoteB device VID 8:
1.3.6.1.4.1.4756.20.482.40.1.133Columnf1000EASX2FVID9RemoteBread-writecurrentRemoteB device VID 9:
1.3.6.1.4.1.4756.20.482.40.1.134Columnf1000EASX2FVID10RemoteBread-writecurrentRemoteB device VID 10:
1.3.6.1.4.1.4756.20.482.40.1.135Columnf1000EASX2FVID11RemoteBread-writecurrentRemoteB device VID 11:
1.3.6.1.4.1.4756.20.482.40.1.136Columnf1000EASX2FVID12RemoteBread-writecurrentRemoteB device VID 12:
1.3.6.1.4.1.4756.20.482.40.1.137Columnf1000EASX2FVID13RemoteBread-writecurrentRemoteB device VID 13:
1.3.6.1.4.1.4756.20.482.40.1.138Columnf1000EASX2FVID14RemoteBread-writecurrentRemoteB device VID 14:
1.3.6.1.4.1.4756.20.482.40.1.139Columnf1000EASX2FVID15RemoteBread-writecurrentRemoteB device VID 15:
1.3.6.1.4.1.4756.20.482.40.1.140Columnf1000EASX2FVID16RemoteBread-writecurrentRemoteB device VID 16:
1.3.6.1.4.1.4756.20.482.40.1.141Columnf1000EASX2FPort1Member1RemoteBread-writecurrentRemoteB device card port 1 member: 0:Unmodify 1:Untagged 2:Tagged 3:Nonmember
1.3.6.1.4.1.4756.20.482.40.1.142Columnf1000EASX2FPort1Member2RemoteBread-writecurrentRemoteB device card port 1 member 2: 0:Unmodify 1:Untagged 2:Tagged 3:Nonmember
1.3.6.1.4.1.4756.20.482.40.1.143Columnf1000EASX2FPort1Member3RemoteBread-writecurrentRemoteB device card port 1 member 3: 0:Unmodify 1:Untagged 2:Tagged 3:Nonmember
1.3.6.1.4.1.4756.20.482.40.1.144Columnf1000EASX2FPort1Member4RemoteBread-writecurrentRemoteB device card port 1 member 4: 0:Unmodify 1:Untagged 2:Tagged 3:Nonmember
1.3.6.1.4.1.4756.20.482.40.1.145Columnf1000EASX2FPort1Member5RemoteBread-writecurrentRemoteB device card port 1 member 5: 0:Unmodify 1:Untagged 2:Tagged 3:Nonmember
1.3.6.1.4.1.4756.20.482.40.1.146Columnf1000EASX2FPort1Member6RemoteBread-writecurrentRemoteB device card port 1 member 6: 0:Unmodify 1:Untagged 2:Tagged 3:Nonmember
1.3.6.1.4.1.4756.20.482.40.1.147Columnf1000EASX2FPort1Member7RemoteBread-writecurrentRemoteB device card port 1 member 7: 0:Unmodify 1:Untagged 2:Tagged 3:Nonmember
1.3.6.1.4.1.4756.20.482.40.1.148Columnf1000EASX2FPort1Member8RemoteBread-writecurrentRemoteB device card port 1 member 8: 0:Unmodify 1:Untagged 2:Tagged 3:Nonmember
1.3.6.1.4.1.4756.20.482.40.1.149Columnf1000EASX2FPort1Member9RemoteBread-writecurrentRemoteB device card port 1 member 9: 0:Unmodify 1:Untagged 2:Tagged 3:Nonmember
1.3.6.1.4.1.4756.20.482.40.1.150Columnf1000EASX2FPort1Member10RemoteBread-writecurrentRemoteB device card port 1 member 10: 0:Unmodify 1:Untagged 2:Tagged 3:Nonmember
1.3.6.1.4.1.4756.20.482.40.1.151Columnf1000EASX2FPort1Member11RemoteBread-writecurrentRemoteB device card port 1 member 11: 0:Unmodify 1:Untagged 2:Tagged 3:Nonmember
1.3.6.1.4.1.4756.20.482.40.1.152Columnf1000EASX2FPort1Member12RemoteBread-writecurrentRemoteB device card port 1 member 12: 0:Unmodify 1:Untagged 2:Tagged 3:Nonmember
1.3.6.1.4.1.4756.20.482.40.1.153Columnf1000EASX2FPort1Member13RemoteBread-writecurrentRemoteB device card port 1 member 13: 0:Unmodify 1:Untagged 2:Tagged 3:Nonmember
1.3.6.1.4.1.4756.20.482.40.1.154Columnf1000EASX2FPort1Member14RemoteBread-writecurrentRemoteB device card port 1 member 14: 0:Unmodify 1:Untagged 2:Tagged 3:Nonmember
1.3.6.1.4.1.4756.20.482.40.1.155Columnf1000EASX2FPort1Member15RemoteBread-writecurrentRemoteB device card port 1 member 15: 0:Unmodify 1:Untagged 2:Tagged 3:Nonmember
1.3.6.1.4.1.4756.20.482.40.1.156Columnf1000EASX2FPort1Member16RemoteBread-writecurrentRemoteB device card port 1 member 16: 0:Unmodify 1:Untagged 2:Tagged 3:Nonmember
1.3.6.1.4.1.4756.20.482.40.1.157Columnf1000EASX2FPort2Member1RemoteBread-writecurrentRemoteB device card port 2 member: 0:Unmodify 1:Untagged 2:Tagged 3:Nonmember
1.3.6.1.4.1.4756.20.482.40.1.158Columnf1000EASX2FPort2Member2RemoteBread-writecurrentRemoteB device card port 2 member 2: 0:Unmodify 1:Untagged 2:Tagged 3:Nonmember
1.3.6.1.4.1.4756.20.482.40.1.159Columnf1000EASX2FPort2Member3RemoteBread-writecurrentRemoteB device card port 2 member 3: 0:Unmodify 1:Untagged 2:Tagged 3:Nonmember
1.3.6.1.4.1.4756.20.482.40.1.160Columnf1000EASX2FPort2Member4RemoteBread-writecurrentRemoteB device card port 2 member 4: 0:Unmodify 1:Untagged 2:Tagged 3:Nonmember
1.3.6.1.4.1.4756.20.482.40.1.161Columnf1000EASX2FPort2Member5RemoteBread-writecurrentRemoteB device card port 2 member 5: 0:Unmodify 1:Untagged 2:Tagged 3:Nonmember
1.3.6.1.4.1.4756.20.482.40.1.162Columnf1000EASX2FPort2Member6RemoteBread-writecurrentRemoteB device card port 2 member 6: 0:Unmodify 1:Untagged 2:Tagged 3:Nonmember
1.3.6.1.4.1.4756.20.482.40.1.163Columnf1000EASX2FPort2Member7RemoteBread-writecurrentRemoteB device card port 2 member 7: 0:Unmodify 1:Untagged 2:Tagged 3:Nonmember
1.3.6.1.4.1.4756.20.482.40.1.164Columnf1000EASX2FPort2Member8RemoteBread-writecurrentRemoteB device card port 2 member 8: 0:Unmodify 1:Untagged 2:Tagged 3:Nonmember
1.3.6.1.4.1.4756.20.482.40.1.165Columnf1000EASX2FPort2Member9RemoteBread-writecurrentRemoteB device card port 2 member 9: 0:Unmodify 1:Untagged 2:Tagged 3:Nonmember
1.3.6.1.4.1.4756.20.482.40.1.166Columnf1000EASX2FPort2Member10RemoteBread-writecurrentRemoteB device card port 2 member 10: 0:Unmodify 1:Untagged 2:Tagged 3:Nonmember
1.3.6.1.4.1.4756.20.482.40.1.167Columnf1000EASX2FPort2Member11RemoteBread-writecurrentRemoteB device card port 2 member 11: 0:Unmodify 1:Untagged 2:Tagged 3:Nonmember
1.3.6.1.4.1.4756.20.482.40.1.168Columnf1000EASX2FPort2Member12RemoteBread-writecurrentRemoteB device card port 2 member 12: 0:Unmodify 1:Untagged 2:Tagged 3:Nonmember
1.3.6.1.4.1.4756.20.482.40.1.169Columnf1000EASX2FPort2Member13RemoteBread-writecurrentRemoteB device card port 2 member 13: 0:Unmodify 1:Untagged 2:Tagged 3:Nonmember
1.3.6.1.4.1.4756.20.482.40.1.170Columnf1000EASX2FPort2Member14RemoteBread-writecurrentRemoteB device card port 2 member 14: 0:Unmodify 1:Untagged 2:Tagged 3:Nonmember
1.3.6.1.4.1.4756.20.482.40.1.171Columnf1000EASX2FPort2Member15RemoteBread-writecurrentRemoteB device card port 2 member 15: 0:Unmodify 1:Untagged 2:Tagged 3:Nonmember
1.3.6.1.4.1.4756.20.482.40.1.172Columnf1000EASX2FPort2Member16RemoteBread-writecurrentRemoteB device card port 2 member 16: 0:Unmodify 1:Untagged 2:Tagged 3:Nonmember
1.3.6.1.4.1.4756.20.482.40.1.173Columnf1000EASX2FIpAddressRemoteBread-writecurrentRemoteB device IP address
1.3.6.1.4.1.4756.20.482.40.1.174Columnf1000EASX2FNetMaskRemoteBread-writecurrentRemoteB device Netmask
1.3.6.1.4.1.4756.20.482.40.1.175Columnf1000EASX2FGateWayRemoteBread-writecurrentRemoteB device Gateway
1.3.6.1.4.1.4756.20.482.40.1.176Columnf1000EASX2FSetDefaultRemoteBread-writecurrentRemoteB device set to default
1.3.6.1.4.1.4756.20.482.40.1.177Columnf1000EASX2FFx1LinkAlarmRemoteBread-writecurrentRemoteB device fiber 1 link alarm 0:Disable 1:Enable
1.3.6.1.4.1.4756.20.482.40.1.178Columnf1000EASX2FFx2LinkAlarmRemoteBread-writecurrentRemoteB device fiber 2 link alarm 0:Disable 1:Enable
1.3.6.1.4.1.4756.20.482.40.1.179Columnf1000EASX2FFHRModeRemoteBread-writecurrentRemoteB device card FHR Mode: 0:Disable 1:Enable
1.3.6.1.4.1.4756.20.482.40.1.180Columnf1000EASX2FRemoteTLPTRemoteBread-writecurrentRemoteB device Remote TLPT mode : 0:Disalbe 1:Remote A 2:Remote B
1.3.6.1.4.1.4756.20.490Nodef16G3RCards
1.3.6.1.4.1.4756.20.490.20Tablef16G3RTablenot-accessiblecurrentA list of local FRM220-16G-3R card entries. The number of entries is f16G3R-No-L.
1.3.6.1.4.1.4756.20.490.20.1Rowf16G3REntrynot-accessiblecurrentAn entry containing management information applicable to a particular local FRM220-16G-3R card.
1.3.6.1.4.1.4756.20.490.20.1.1Columnf16G3RChassisIndexread-onlycurrentA unique value for each local card. It is the chassis location number.
1.3.6.1.4.1.4756.20.490.20.1.2Columnf16G3RSlotIndexread-onlycurrentA unique value for each local card. It is the slot location number.
1.3.6.1.4.1.4756.20.490.20.1.3Columnf16G3RCardHWVerread-onlycurrentLocal FRM220-16G-3R card hardware version x.xxx
1.3.6.1.4.1.4756.20.490.20.1.4Columnf16G3RCardFWVerread-onlycurrentLocal FRM220-16G-3R card firmware version x.xxx
1.3.6.1.4.1.4756.20.490.20.1.5Columnf16G3RCardCPLDVerread-onlycurrentLocal FRM220-16G-3R card CPLD version x.xxx
1.3.6.1.4.1.4756.20.490.20.1.6Columnf16G3RCardFPGAVerread-onlycurrentLocal FRM220-16G-3R card FPGA version x.xxx
1.3.6.1.4.1.4756.20.490.20.1.7Columnf16G3RFx1Linkread-onlycurrentLocal FRM220-16G-3R card Fiber1 link status: 0:Down 1:Up
1.3.6.1.4.1.4756.20.490.20.1.8Columnf16G3RFx2Linkread-onlycurrentLocal FRM220-16G-3R card Fiber2 link status: 0:Down 1:Up
1.3.6.1.4.1.4756.20.490.20.1.9Columnf16G3RFx3Linkread-onlycurrentLocal FRM220-16G-3R card Fiber3 link status: 0:Down 1:Up
1.3.6.1.4.1.4756.20.490.20.1.10Columnf16G3RFx4Linkread-onlycurrentLocal FRM220-16G-3R card Fiber4 link status: 0:Down 1:Up
1.3.6.1.4.1.4756.20.490.20.1.11Columnf16G3RFx1CDRLockedread-onlycurrentLocal FRM220-16G-3R card Fiber1 CRD Locked: 0:Not Locked 1:Locked
1.3.6.1.4.1.4756.20.490.20.1.12Columnf16G3RFx2CDRLockedread-onlycurrentLocal FRM220-16G-3R card Fiber2 CRD Locked: 0:Not Locked 1:Locked
1.3.6.1.4.1.4756.20.490.20.1.13Columnf16G3RFx3CDRLockedread-onlycurrentLocal FRM220-16G-3R card Fiber3 CRD Locked: 0:Not Locked 1:Locked
1.3.6.1.4.1.4756.20.490.20.1.14Columnf16G3RFx4CDRLockedread-onlycurrentLocal FRM220-16G-3R card Fiber4 CRD Locked: 0:Not Locked 1:Locked
1.3.6.1.4.1.4756.20.490.20.1.15Columnf16G3RFx1TxFaultread-onlycurrentLocal FRM220-16G-3R card Fiber1 Tx Fault: 0:Normal 1:Failure
1.3.6.1.4.1.4756.20.490.20.1.16Columnf16G3RFx2TxFaultread-onlycurrentLocal FRM220-16G-3R card Fiber2 Tx Fault: 0:Normal 1:Failure
1.3.6.1.4.1.4756.20.490.20.1.17Columnf16G3RFx3TxFaultread-onlycurrentLocal FRM220-16G-3R card Fiber3 Tx Fault: 0:Normal 1:Failure
1.3.6.1.4.1.4756.20.490.20.1.18Columnf16G3RFx4TxFaultread-onlycurrentLocal FRM220-16G-3R card Fiber4 Tx Fault: 0:Normal 1:Failure
1.3.6.1.4.1.4756.20.490.20.1.19Columnf16G3RFx1DDread-onlycurrentLocal FRM220-16G-3R card fiber1 Digital Diagnostic function: 0:No 1:Yes
1.3.6.1.4.1.4756.20.490.20.1.20Columnf16G3RFx2DDread-onlycurrentLocal FRM220-16G-3R card fiber2 Digital Diagnostic function: 0:No 1:Yes
1.3.6.1.4.1.4756.20.490.20.1.21Columnf16G3RFx3DDread-onlycurrentLocal FRM220-16G-3R card fiber3 Digital Diagnostic function: 0:No 1:Yes
1.3.6.1.4.1.4756.20.490.20.1.22Columnf16G3RFx4DDread-onlycurrentLocal FRM220-16G-3R card fiber4 Digital Diagnostic function: 0:No 1:Yes
1.3.6.1.4.1.4756.20.490.20.1.23Columnf16G3RFx1DDStatusread-onlycurrentLocal FRM220-16G-3R card fiber1 D/D information: Status Support
1.3.6.1.4.1.4756.20.490.20.1.24Columnf16G3RFx2DDStatusread-onlycurrentLocal FRM220-16G-3R card fiber2 D/D information: Status Support
1.3.6.1.4.1.4756.20.490.20.1.25Columnf16G3RFx3DDStatusread-onlycurrentLocal FRM220-16G-3R card fiber3 D/D information: Status Support
1.3.6.1.4.1.4756.20.490.20.1.26Columnf16G3RFx4DDStatusread-onlycurrentLocal FRM220-16G-3R card fiber4 D/D information: Status Support
1.3.6.1.4.1.4756.20.490.20.1.27Columnf16G3RDeviceActiveread-writecurrentLocal FRM220-16G-3R card active: 0:Inactive 1:Active
1.3.6.1.4.1.4756.20.490.20.1.28Columnf16G3RPortResetread-writecurrentForce local FRM220-16G-3R card to reset mode: 0:Off 1:Action
1.3.6.1.4.1.4756.20.490.20.1.29Columnf16G3RSetDefaultread-writecurrentLocal FRM220-16G-3R card set to default : 0:Off 1:Action
1.3.6.1.4.1.4756.20.490.20.1.30Columnf16G3RWorkModeread-writecurrentLocal FRM220-16G-3R card Work Mode : 0:Protection 1:Dual Channel
1.3.6.1.4.1.4756.20.490.20.1.31Columnf16G3RFx1Lbsettingread-writecurrentLocal FRM220-16G-3R card Fiber1 Loopback: 0:Disable 1:Enable
1.3.6.1.4.1.4756.20.490.20.1.32Columnf16G3RFx2Lbsettingread-writecurrentLocal FRM220-16G-3R card Fiber2 Loopback: 0:Disable 1:Enable
1.3.6.1.4.1.4756.20.490.20.1.33Columnf16G3RFx3Lbsettingread-writecurrentLocal FRM220-16G-3R card Fiber3 Loopback: 0:Disable 1:Enable
1.3.6.1.4.1.4756.20.490.20.1.34Columnf16G3RFx4Lbsettingread-writecurrentLocal FRM220-16G-3R card Fiber4 Loopback: 0:Disable 1:Enable
1.3.6.1.4.1.4756.20.490.20.1.35Columnf16G3RFx1LFPTread-writecurrentLocal FRM220-16G-3R card Fiber1 Link Fault Pass Through: 0:Disable 1:Enable
1.3.6.1.4.1.4756.20.490.20.1.36Columnf16G3RFx2LFPTread-writecurrentLocal FRM220-16G-3R card Fiber2 Link Fault Pass Through: 0:Disable 1:Enable
1.3.6.1.4.1.4756.20.490.20.1.37Columnf16G3RFx3LFPTread-writecurrentLocal FRM220-16G-3R card Fiber3 Link Fault Pass Through: 0:Disable 1:Enable
1.3.6.1.4.1.4756.20.490.20.1.38Columnf16G3RFx4LFPTread-writecurrentLocal FRM220-16G-3R card Fiber4 Link Fault Pass Through: 0:Disable 1:Enable
1.3.6.1.4.1.4756.20.490.20.1.39Columnf16G3RFx1ALSModeread-writecurrentLocal FRM220-16G-3R card Fiber1 Auto Laser Showdown: 0:Disable 1:Enable
1.3.6.1.4.1.4756.20.490.20.1.40Columnf16G3RFx2ALSModeread-writecurrentLocal FRM220-16G-3R card Fiber2 Auto Laser Showdown: 0:Disable 1:Enable
1.3.6.1.4.1.4756.20.490.20.1.41Columnf16G3RFx3ALSModeread-writecurrentLocal FRM220-16G-3R card Fiber3 Auto Laser Showdown: 0:Disable 1:Enable
1.3.6.1.4.1.4756.20.490.20.1.42Columnf16G3RFx4ALSModeread-writecurrentLocal FRM220-16G-3R card Fiber4 Auto Laser Showdown: 0:Disable 1:Enable
1.3.6.1.4.1.4756.20.490.20.1.43Columnf16G3RFx1LinkAlarmread-writecurrentLocal FRM220-16G-3R card Fx1 Link Alarm: 0:Disalbe 1:Enable
1.3.6.1.4.1.4756.20.490.20.1.44Columnf16G3RFx2LinkAlarmread-writecurrentLocal FRM220-16G-3R card Fx2 Link Alarm: 0:Disalbe 1:Enable
1.3.6.1.4.1.4756.20.490.20.1.45Columnf16G3RFx3LinkAlarmread-writecurrentLocal FRM220-16G-3R card Fx3 Link Alarm: 0:Disalbe 1:Enable
1.3.6.1.4.1.4756.20.490.20.1.46Columnf16G3RFx4LinkAlarmread-writecurrentLocal FRM220-16G-3R card Fx4 Link Alarm: 0:Disalbe 1:Enable
1.3.6.1.4.1.4756.20.490.20.1.47Columnf16G3RSemiActiveread-writecurrentLocal FRM220-16G-3R card Semi-Active (Protection mode only): 0:Disalbe 1:Enable
1.3.6.1.4.1.4756.20.490.20.1.48Columnf16G3RWorkingPathStatusread-onlycurrentLocal FRM220-16G-3R card Workinng Path Status (Protection mode only): 0:Primary 1:Secondary
1.3.6.1.4.1.4756.20.490.20.1.49Columnf16G3RWorkingPathread-writecurrentLocal FRM220-16G-3R card Workinng Path(Protection mode only): 0:Auto-Revert 1:Non Revert 2:Primary 3:Secondary
1.3.6.1.4.1.4756.20.490.20.1.50Columnf16G3RDataRatelStatusread-onlycurrentLocal FRM220-16G-3R card Data Rate 1 Status:
1.3.6.1.4.1.4756.20.490.20.1.51Columnf16G3RDataRate2Statusread-onlycurrentLocal FRM220-16G-3R card Data Rate 2 Status(Dual Channel mode only):
1.3.6.1.4.1.4756.20.490.20.1.52Columnf16G3RProtocol1read-onlycurrentLocal FRM220-16G-3R card Protocol 1: 0:Ethernet 1:SONET/SDH 2:Fiber Channel 3:CPRI 4:OBSAI 5:OTU 6:ODU
1.3.6.1.4.1.4756.20.490.20.1.53Columnf16G3RRate1read-writecurrentLocal FRM220-16G-3R card Rate 1: Ethernet 0: 10GE 1: 1GE 2: 2500Base-X SONET/SDH 8: OC-192/STM-64 9: OC-48/STM-16 10:OC-24 11:OC-12/STM-4 Fiber Channel 16: 16G…
1.3.6.1.4.1.4756.20.490.20.1.54Columnf16G3RProtocol2read-onlycurrentLocal FRM220-16G-3R Protocol 2 (Dual Channel only): 0:Ethernet 1:SONET/SDH 2:Fiber Channel 3:CPRI 4:OBSAI 5:OTU 6:ODU
1.3.6.1.4.1.4756.20.490.20.1.55Columnf16G3RRate2read-writecurrentLocal FRM220-16G-3R card Rate2(Dual Channel only): Ethernet 0: 10GE 1: 1GE 2: 2500Base-X SONET/SDH 8: OC-192/STM-64 9: OC-48/STM-16 10:OC-24 11:OC-12/STM-4 Fib…
1.3.6.1.4.1.4756.20.490.20.1.56Columnf16G3RChannel1Activeread-writecurrentLocal FRM220-16G-3R card Channel 1 Active(Dual Channel only): 0:Disable 1:Enable
1.3.6.1.4.1.4756.20.490.20.1.57Columnf16G3RChannel2Activeread-writecurrentLocal FRM220-16G-3R card Channel 2 Active(Dual Channel only): 0:Disable 1:Enable
1.3.6.1.4.1.4756.20.490.20.1.58Columnf16G3RFx1DDVendorread-onlycurrentLocal FRM220-16G-3R card fiber1 D/D information: Vendor name
1.3.6.1.4.1.4756.20.490.20.1.59Columnf16G3RFx1DDPartNoread-onlycurrentLocal FRM220-16G-3R card fiber1 D/D information: Vendor part number
1.3.6.1.4.1.4756.20.490.20.1.60Columnf16G3RFx1DDVendorSNread-onlycurrentLocal FRM220-16G-3R card fiber1 D/D information: Vendor Serial number
1.3.6.1.4.1.4756.20.490.20.1.61Columnf16G3RFx1DDFiberTyperead-onlycurrentLocal FRM220-16G-3R card fiber1 D/D information: Fiber Type
1.3.6.1.4.1.4756.20.490.20.1.62Columnf16G3RFx1DDWaveLenread-onlycurrentLocal FRM220-16G-3R card fiber1 D/D information: Wave length
1.3.6.1.4.1.4756.20.490.20.1.63Columnf16G3RFx1DDWaveLen2read-onlycurrentLocal FRM220-16G-3R card fiber1 D/D information: Wave length 2
1.3.6.1.4.1.4756.20.490.20.1.64Columnf16G3RFx1DDLinkLenread-onlycurrentLocal FRM220-16G-3R card fiber1 D/D information: Link length
1.3.6.1.4.1.4756.20.490.20.1.65Columnf16G3RFx1DDLenUnitread-onlycurrentLocal FRM220-16G-3R card fiber1 D/D information: Length Unit
1.3.6.1.4.1.4756.20.490.20.1.66Columnf16G3RFx1DDRxSensread-onlycurrentLocal FRM220-16G-3R card fiber1 D/D information: Rx Sensitivity
1.3.6.1.4.1.4756.20.490.20.1.67Columnf16G3RFx1DDTxPWRread-onlycurrentLocal FRM220-16G-3R card fiber1 D/D information: Tx power
1.3.6.1.4.1.4756.20.490.20.1.68Columnf16G3RFx1DDRxPWRread-onlycurrentLocal FRM220-16G-3R card fiber1 D/D information: Rx power
1.3.6.1.4.1.4756.20.490.20.1.69Columnf16G3RFx1RxPowerStatusread-onlycurrentLocal FRM220-16G-3R card fiber1 Rx Power Status: 0:Normal 1:Warning 2:Alarm
1.3.6.1.4.1.4756.20.490.20.1.70Columnf16G3RFx1DDTempread-onlycurrentLocal FRM220-16G-3R card fiber1 D/D information: Temperature in degree C
1.3.6.1.4.1.4756.20.490.20.1.71Columnf16G3RFx1DDPWRMarginread-onlycurrentLocal FRM220-16G-3R card fiber1 D/D information: Power margin
1.3.6.1.4.1.4756.20.490.20.1.72Columnf16G3RFx2DDVendorread-onlycurrentLocal FRM220-16G-3R card fiber2 D/D information: Vendor name
1.3.6.1.4.1.4756.20.490.20.1.73Columnf16G3RFx2DDPartNoread-onlycurrentLocal FRM220-16G-3R card fiber2 D/D information: Vendor part number
1.3.6.1.4.1.4756.20.490.20.1.74Columnf16G3RFx2DDVendorSNread-onlycurrentLocal FRM220-16G-3R card fiber2 D/D information: Vendor Serial number
1.3.6.1.4.1.4756.20.490.20.1.75Columnf16G3RFx2DDFiberTyperead-onlycurrentLocal FRM220-16G-3R card fiber2 D/D information: Fiber Type
1.3.6.1.4.1.4756.20.490.20.1.76Columnf16G3RFx2DDWaveLenread-onlycurrentLocal FRM220-16G-3R card fiber2 D/D information: Wave length
1.3.6.1.4.1.4756.20.490.20.1.77Columnf16G3RFx2DDWaveLen2read-onlycurrentLocal FRM220-16G-3R card fiber2 D/D information: Wave length 2
1.3.6.1.4.1.4756.20.490.20.1.78Columnf16G3RFx2DDLinkLenread-onlycurrentLocal FRM220-16G-3R card fiber2 D/D information: Link length
1.3.6.1.4.1.4756.20.490.20.1.79Columnf16G3RFx2DDLenUnitread-onlycurrentLocal FRM220-16G-3R card fiber2 D/D information: Length Unit
1.3.6.1.4.1.4756.20.490.20.1.80Columnf16G3RFx2DDRxSensread-onlycurrentLocal FRM220-16G-3R card fiber2 D/D information: Rx Sensitivity
1.3.6.1.4.1.4756.20.490.20.1.81Columnf16G3RFx2DDTxPWRread-onlycurrentLocal FRM220-16G-3R card fiber2 D/D information: Tx power
1.3.6.1.4.1.4756.20.490.20.1.82Columnf16G3RFx2DDRxPWRread-onlycurrentLocal FRM220-16G-3R card fiber2 D/D information: Rx power
1.3.6.1.4.1.4756.20.490.20.1.83Columnf16G3RFx2RxPowerStatusread-onlycurrentLocal FRM220-16G-3R card fiber2 Rx Power Status: 0:Normal 1:Warning 2:Alarm
1.3.6.1.4.1.4756.20.490.20.1.84Columnf16G3RFx2DDTempread-onlycurrentLocal FRM220-16G-3R card fiber2 D/D information: Temperature in degree C
1.3.6.1.4.1.4756.20.490.20.1.85Columnf16G3RFx2DDPWRMarginread-onlycurrentLocal FRM220-16G-3R card fiber2 D/D information: Power margin
1.3.6.1.4.1.4756.20.490.20.1.86Columnf16G3RFx3DDVendorread-onlycurrentLocal FRM220-16G-3R card fiber3 D/D information: Vendor name
1.3.6.1.4.1.4756.20.490.20.1.87Columnf16G3RFx3DDPartNoread-onlycurrentLocal FRM220-16G-3R card fiber3 D/D information: Vendor part number
1.3.6.1.4.1.4756.20.490.20.1.88Columnf16G3RFx3DDVendorSNread-onlycurrentLocal FRM220-16G-3R card fiber3 D/D information: Vendor Serial number
1.3.6.1.4.1.4756.20.490.20.1.89Columnf16G3RFx3DDFiberTyperead-onlycurrentLocal FRM220-16G-3R card fiber3 D/D information: Fiber Type
1.3.6.1.4.1.4756.20.490.20.1.90Columnf16G3RFx3DDWaveLenread-onlycurrentLocal FRM220-16G-3R card fiber3 D/D information: Wave length
1.3.6.1.4.1.4756.20.490.20.1.91Columnf16G3RFx3DDWaveLen2read-onlycurrentLocal FRM220-16G-3R card fiber3 D/D information: Wave length 2
1.3.6.1.4.1.4756.20.490.20.1.92Columnf16G3RFx3DDLinkLenread-onlycurrentLocal FRM220-16G-3R card fiber3 D/D information: Link length
1.3.6.1.4.1.4756.20.490.20.1.93Columnf16G3RFx3DDLenUnitread-onlycurrentLocal FRM220-16G-3R card fiber3 D/D information: Length Unit
1.3.6.1.4.1.4756.20.490.20.1.94Columnf16G3RFx3DDRxSensread-onlycurrentLocal FRM220-16G-3R card fiber3 D/D information: Rx Sensitivity
1.3.6.1.4.1.4756.20.490.20.1.95Columnf16G3RFx3DDTxPWRread-onlycurrentLocal FRM220-16G-3R card fiber3 D/D information: Tx power
1.3.6.1.4.1.4756.20.490.20.1.96Columnf16G3RFx3DDRxPWRread-onlycurrentLocal FRM220-16G-3R card fiber3 D/D information: Rx power
1.3.6.1.4.1.4756.20.490.20.1.97Columnf16G3RFx3RxPowerStatusread-onlycurrentLocal FRM220-16G-3R card fiber3 Rx Power Status: 0:Normal 1:Warning 2:Alarm
1.3.6.1.4.1.4756.20.490.20.1.98Columnf16G3RFx3DDTempread-onlycurrentLocal FRM220-16G-3R card fiber3 D/D information: Temperature in degree C
1.3.6.1.4.1.4756.20.490.20.1.99Columnf16G3RFx3DDPWRMarginread-onlycurrentLocal FRM220-16G-3R card fiber3 D/D information: Power margin
1.3.6.1.4.1.4756.20.490.20.1.100Columnf16G3RFx4DDVendorread-onlycurrentLocal FRM220-16G-3R card fiber4 D/D information: Vendor name
1.3.6.1.4.1.4756.20.490.20.1.101Columnf16G3RFx4DDPartNoread-onlycurrentLocal FRM220-16G-3R card fiber4 D/D information: Vendor part number
1.3.6.1.4.1.4756.20.490.20.1.102Columnf16G3RFx4DDVendorSNread-onlycurrentLocal FRM220-16G-3R card fiber4 D/D information: Vendor Serial number
1.3.6.1.4.1.4756.20.490.20.1.103Columnf16G3RFx4DDFiberTyperead-onlycurrentLocal FRM220-16G-3R card fiber4 D/D information: Fiber Type
1.3.6.1.4.1.4756.20.490.20.1.104Columnf16G3RFx4DDWaveLenread-onlycurrentLocal FRM220-16G-3R card fiber4 D/D information: Wave length
1.3.6.1.4.1.4756.20.490.20.1.105Columnf16G3RFx4DDWaveLen2read-onlycurrentLocal FRM220-16G-3R card fiber4 D/D information: Wave length 2
1.3.6.1.4.1.4756.20.490.20.1.106Columnf16G3RFx4DDLinkLenread-onlycurrentLocal FRM220-16G-3R card fiber4 D/D information: Link length
1.3.6.1.4.1.4756.20.490.20.1.107Columnf16G3RFx4DDLenUnitread-onlycurrentLocal FRM220-16G-3R card fiber4 D/D information: Length Unit
1.3.6.1.4.1.4756.20.490.20.1.108Columnf16G3RFx4DDRxSensread-onlycurrentLocal FRM220-16G-3R card fiber4 D/D information: Rx Sensitivity
1.3.6.1.4.1.4756.20.490.20.1.109Columnf16G3RFx4DDTxPWRread-onlycurrentLocal FRM220-16G-3R card fiber4 D/D information: Tx power
1.3.6.1.4.1.4756.20.490.20.1.110Columnf16G3RFx4DDRxPWRread-onlycurrentLocal FRM220-16G-3R card fiber4 D/D information: Rx power
1.3.6.1.4.1.4756.20.490.20.1.111Columnf16G3RFx4RxPowerStatusread-onlycurrentLocal FRM220-16G-3R card fiber4 Rx Power Status: 0:Normal 1:Warning 2:Alarm
1.3.6.1.4.1.4756.20.490.20.1.112Columnf16G3RFx4DDTempread-onlycurrentLocal FRM220-16G-3R card fiber4 D/D information: Temperature in degree C
1.3.6.1.4.1.4756.20.490.20.1.113Columnf16G3RFx4DDPWRMarginread-onlycurrentLocal FRM220-16G-3R card fiber4 D/D information: Power margin
1.3.6.1.4.1.4756.20.490.20.1.114Columnf16G3RFx1RxPowerStatusAlarmread-writecurrentLocal FRM220-16G-3R card Line Rx Power Status trap. 0:Disable 1:Enable
1.3.6.1.4.1.4756.20.490.20.1.115Columnf16G3RFx1LosAssertAlarmread-writecurrentLocal FRM220-16G-3R card Line LOS Assert trap. 0:Disable 1:Enable
1.3.6.1.4.1.4756.20.490.20.1.116Columnf16G3RFx1RxPowerWarningThresholdread-writecurrentSet Line Rx Power Warning Threshold: Input range is from -60 to +10.
1.3.6.1.4.1.4756.20.490.20.1.117Columnf16G3RFx1RxPowerAlarmThresholdread-writecurrentSet Line Rx Power Alarm Threshold: Input range is from -60 to +10.
1.3.6.1.4.1.4756.20.490.20.1.118Columnf16G3RFx2RxPowerStatusAlarmread-writecurrentLocal FRM220-16G-3R card Primary Rx Power Status trap. 0:Disable 1:Enable
1.3.6.1.4.1.4756.20.490.20.1.119Columnf16G3RFx2LosAssertAlarmread-writecurrentLocal FRM220-16G-3R card Primary LOS Assert trap. 0:Disable 1:Enable
1.3.6.1.4.1.4756.20.490.20.1.120Columnf16G3RFx2RxPowerWarningThresholdread-writecurrentSet Primary Rx Power Warning Threshold: Input range is from -60 to +10.
1.3.6.1.4.1.4756.20.490.20.1.121Columnf16G3RFx2RxPowerAlarmThresholdread-writecurrentSet Primary Rx Power Alarm Threshold: Input range is from -60 to +10.
1.3.6.1.4.1.4756.20.490.20.1.122Columnf16G3RFx3RxPowerStatusAlarmread-writecurrentLocal FRM220-16G-3R card Secondary Rx Power Status trap. 0:Disable 1:Enable
1.3.6.1.4.1.4756.20.490.20.1.123Columnf16G3RFx3LosAssertAlarmread-writecurrentLocal FRM220-16G-3R card Secondary LOS Assert trap. 0:Disable 1:Enable
1.3.6.1.4.1.4756.20.490.20.1.124Columnf16G3RFx3RxPowerWarningThresholdread-writecurrentSet Secondary Rx Power Warning Threshold: Input range is from -60 to +10.
1.3.6.1.4.1.4756.20.490.20.1.125Columnf16G3RFx3RxPowerAlarmThresholdread-writecurrentSet Secondary Rx Power Alarm Threshold: Input range is from -60 to +10.
1.3.6.1.4.1.4756.20.490.20.1.126Columnf16G3RFx4RxPowerStatusAlarmread-writecurrentLocal FRM220-16G-3R card Fx4 Rx Power Status trap. 0:Disable 1:Enable
1.3.6.1.4.1.4756.20.490.20.1.127Columnf16G3RFx4LosAssertAlarmread-writecurrentLocal FRM220-16G-3R card Fx4 LOS Assert trap. 0:Disable 1:Enable
1.3.6.1.4.1.4756.20.490.20.1.128Columnf16G3RFx4RxPowerWarningThresholdread-writecurrentSet Secondary Rx Power Warning Threshold: Input range is from -60 to +10.
1.3.6.1.4.1.4756.20.490.20.1.129Columnf16G3RFx4RxPowerAlarmThresholdread-writecurrentSet Secondary Rx Power Alarm Threshold: Input range is from -60 to +10.
1.3.6.1.4.1.4756.20.490.20.1.130Columnf16G3RTemperatureread-onlycurrentLocal FRM220-16G-3R card temperature information: Temperature in degree C
1.3.6.1.4.1.4756.20.490.20.1.131Columnf16G3RPowerLedread-onlycurrentLocal FRM220-16G-3R card Powe Led. 0:ON (Power ON) 1:Flash (Standby; 1s ON/1s OFF)
1.3.6.1.4.1.4756.20.490.20.1.132Columnf16G3RSystemLedread-onlycurrentLocal FRM220-16G-3R card Syetem Led. 0:OFF(Fail) 1:ON (Normal)
1.3.6.1.4.1.4756.20.490.20.1.133Columnf16G3RModeLedread-onlycurrentLocal FRM220-16G-3R card Mode Led. 0:OFF(Dual Channel) 1:ON (Protection)
1.3.6.1.4.1.4756.20.490.20.1.134Columnf16G3RTestLedread-onlycurrentLocal FRM220-16G-3R card Test Led. 0:OFF(Normal) 1:ON (Test; Loopback Test)
1.3.6.1.4.1.4756.20.490.20.1.135Columnf16G3RFx1Ledread-onlycurrentLocal FRM220-16G-3R card Fx1 Led. 0:OFF(Link Down) 1:ON (SYNC) 2:LB (0.1s ON/0.1s OFF) 3:Link Up (0.5s ON/0.5s OFF)
1.3.6.1.4.1.4756.20.490.20.1.136Columnf16G3RFx2Ledread-onlycurrentLocal FRM220-16G-3R card Fx2 Led. 0:OFF(Link Down) 1:ON (SYNC) 2:LB (0.1s ON/0.1s OFF) 3:Link Up (0.5s ON/0.5s OFF) 4:Working Path (3s ON/0.2s OFF)
1.3.6.1.4.1.4756.20.490.20.1.137Columnf16G3RFx3Ledread-onlycurrentLocal FRM220-16G-3R card Fx3 Led. 0:OFF(Link Down) 1:ON (SYNC) 2:LB (0.1s ON/0.1s OFF) 3:Link Up (0.5s ON/0.5s OFF) 4:Working Path (3s ON/0.2s OFF)
1.3.6.1.4.1.4756.20.490.20.1.138Columnf16G3RFx4Ledread-onlycurrentLocal FRM220-16G-3R card Fx4 Led. 0:OFF(Link Down) 1:ON (SYNC) 2:LB (0.1s ON/0.1s OFF) 3:Link Up (0.5s ON/0.5s OFF)
1.3.6.1.4.1.4756.20.500NodenidLocalCards
1.3.6.1.4.1.4756.20.500.20TablenidLocalTablenot-accessiblecurrentA list of local FRM220-MSW404/MSW404S card entries. The number of entries is f16G3R-No-L.
1.3.6.1.4.1.4756.20.500.20.1RownidLocalEntrynot-accessiblecurrentAn entry containing management information applicable to a particular local FRM220-MSW404/MSW404S card.
1.3.6.1.4.1.4756.20.500.20.1.1ColumnnidChassisIndexLocalread-onlycurrentA unique value for each local card. It is the chassis location number.
1.3.6.1.4.1.4756.20.500.20.1.2ColumnnidSlotIndexLocalread-onlycurrentA unique value for each local card. It is the slot location number.
1.3.6.1.4.1.4756.20.500.20.1.3ColumnnidCardHWVerLocalread-onlycurrentLocal NID card hardware version x.xxx
1.3.6.1.4.1.4756.20.500.20.1.4ColumnnidCardFWVerLocalread-onlycurrentLocal NID card firmware version x.xxx
1.3.6.1.4.1.4756.20.500.20.1.5ColumnnidCardCPLDVerLocalread-onlycurrentLocal NID card CPLD version x.xxx
1.3.6.1.4.1.4756.20.500.20.1.6ColumnnidCardFPGAVerLocalread-onlycurrentLocal NID card FPGA version x.xxx
1.3.6.1.4.1.4756.20.500.20.1.7ColumnnidModelLocalread-onlycurrentCard Type: 0:MSW404 1:MSW404S
1.3.6.1.4.1.4756.20.500.20.1.8ColumnnidDNSServerTypeLocalread-writecurrentNID Series card IP Configuration: This setting controls the DNS name resolution done by the switch. The following modes are supported: 1:From any DHCP interfac…
1.3.6.1.4.1.4756.20.500.20.1.9ColumnnidDNSServerSettingLocalread-writecurrentNID Series card IP Configuration: If iDNSServerType setting '3:Configured',this value must setting IP address format as below: Dotted Decimal Notation refers t…
1.3.6.1.4.1.4756.20.500.20.1.10ColumnnidDNSproxyLocalread-writecurrentNID Series card IP Configuration: When DNS proxy is enabled, system will relay DNS requests to the currently configured DNS server, and reply as a DNS resolver…
1.3.6.1.4.1.4756.20.500.20.1.11ColumnnidAddIPV4InterfaceLocalread-writecurrentNID Series card IP Interfaces: Add a new IP VLAN Interface: Syntax: [<Interface>] [<vlan_list>] [<IPV4_Addr>] [<IPV4_MASK>] Interface : 1~4
1.3.6.1.4.1.4756.20.500.20.1.12ColumnnidDeleteInterfaceLocalread-writecurrentNID Series card IP Interfaces: Delete a IPv4/v6 VLAN Interface: Syntax: [<Interface>] Interface: 1~4
1.3.6.1.4.1.4756.20.500.20.1.13ColumnnidIPInterface1VLANLocalread-onlycurrentNID Series card IP Interfaces: The VLAN associated with the IP interface. Only ports in this VLAN will be able to access the IP interface. This field is only a…
1.3.6.1.4.1.4756.20.500.20.1.14ColumnnidIPInterface1DHCPLocalread-writecurrentNID Series card IP Interfaces: DHCP
1.3.6.1.4.1.4756.20.500.20.1.15ColumnnidIPInterface1FallbackLocalread-writecurrentNID Series card IP Interfaces: Fallback
1.3.6.1.4.1.4756.20.500.20.1.16ColumnnidIPInterface1IPV4AddressLocalread-onlycurrentNID Series card IP Interfaces: IPV4 Address
1.3.6.1.4.1.4756.20.500.20.1.17ColumnnidIPInterface1IPV4MASKLenLocalread-onlycurrentNID Series card IP Interfaces: IPV4 MASK Length
1.3.6.1.4.1.4756.20.500.20.1.18ColumnnidIPInterface2VLANLocalread-onlycurrentNID Series card IP Interfaces: The VLAN associated with the IP interface. Only ports in this VLAN will be able to access the IP interface. This field is only a…
1.3.6.1.4.1.4756.20.500.20.1.19ColumnnidIPInterface2DHCPLocalread-writecurrentNID Series card IP Interfaces: DHCP
1.3.6.1.4.1.4756.20.500.20.1.20ColumnnidIPInterface2FallbackLocalread-writecurrentNID Series card IP Interfaces: Fallback
1.3.6.1.4.1.4756.20.500.20.1.21ColumnnidIPInterface2IPV4AddressLocalread-onlycurrentNID Series card IP Interfaces: IPV4 Address
1.3.6.1.4.1.4756.20.500.20.1.22ColumnnidIPInterface2IPV4MASKLenLocalread-onlycurrentNID Series card IP Interfaces: IPV4 MASK Length
1.3.6.1.4.1.4756.20.500.20.1.23ColumnnidIPInterface3VLANLocalread-onlycurrentNID Series card IP Interfaces: The VLAN associated with the IP interface. Only ports in this VLAN will be able to access the IP interface. This field is only a…
1.3.6.1.4.1.4756.20.500.20.1.24ColumnnidIPInterface3DHCPLocalread-writecurrentNID Series card IP Interfaces: DHCP
1.3.6.1.4.1.4756.20.500.20.1.25ColumnnidIPInterface3FallbackLocalread-writecurrentNID Series card IP Interfaces: Fallback
1.3.6.1.4.1.4756.20.500.20.1.26ColumnnidIPInterface3IPV4AddressLocalread-onlycurrentNID Series card IP Interfaces: IPV4 Address
1.3.6.1.4.1.4756.20.500.20.1.27ColumnnidIPInterface3IPV4MASKLenLocalread-onlycurrentNID Series card IP Interfaces: IPV4 MASK Length
1.3.6.1.4.1.4756.20.500.20.1.28ColumnnidIPInterface4VLANLocalread-onlycurrentNID Series card IP Interfaces: The VLAN associated with the IP interface. Only ports in this VLAN will be able to access the IP interface. This field is only a…
1.3.6.1.4.1.4756.20.500.20.1.29ColumnnidIPInterface4DHCPLocalread-writecurrentNID Series card IP Interfaces: DHCP
1.3.6.1.4.1.4756.20.500.20.1.30ColumnnidIPInterface4FallbackLocalread-writecurrentNID Series card IP Interfaces: Fallback
1.3.6.1.4.1.4756.20.500.20.1.31ColumnnidIPInterface4IPV4AddressLocalread-onlycurrentNID Series card IP Interfaces: IPV4 Address
1.3.6.1.4.1.4756.20.500.20.1.32ColumnnidIPInterface4IPV4MASKLenLocalread-onlycurrentNID Series card IP Interfaces: IPV4 MASK Length
1.3.6.1.4.1.4756.20.500.20.1.33ColumnnidAddIPV6InterfaceLocalread-writecurrentNID Series card IP Interfaces: Add a new IPv6 VLAN Interface: Syntax: [<Interface>] [<vlan_list>] [<IPV4_Addr>] [<IPV4_MASK>] Interface : 1~4
1.3.6.1.4.1.4756.20.500.20.1.34ColumnnidIPInterface1IPV6AddressLocalread-onlycurrentNID Series card IP Interfaces: IPV6 Address
1.3.6.1.4.1.4756.20.500.20.1.35ColumnnidIPInterface1IPV6MASKLenLocalread-onlycurrentNID Series card IP Interfaces: IPV6 MASK Length
1.3.6.1.4.1.4756.20.500.20.1.36ColumnnidIPInterface2IPV6AddressLocalread-onlycurrentNID Series card IP Interfaces: IPV6 Address
1.3.6.1.4.1.4756.20.500.20.1.37ColumnnidIPInterface2IPV6MASKLenLocalread-onlycurrentNID Series card IP Interfaces: IPV6 MASK Length
1.3.6.1.4.1.4756.20.500.20.1.38ColumnnidIPInterface3IPV6AddressLocalread-onlycurrentNID Series card IP Interfaces: IPV6 Address
1.3.6.1.4.1.4756.20.500.20.1.39ColumnnidIPInterface3IPV6MASKLenLocalread-onlycurrentNID Series card IP Interfaces: IPV6 MASK Length
1.3.6.1.4.1.4756.20.500.20.1.40ColumnnidIPInterface4IPV6AddressLocalread-onlycurrentNID Series card IP Interfaces: IPV6 Address
1.3.6.1.4.1.4756.20.500.20.1.41ColumnnidIPInterface4IPV6MASKLenLocalread-onlycurrentNID Series card IP Interfaces: IPV6 MASK Length
1.3.6.1.4.1.4756.20.500.20.1.42ColumnnidPort1LinkstsLocalread-onlycurrentNID Series card Port1 link status: 0:Link down 1:Link up
1.3.6.1.4.1.4756.20.500.20.1.43ColumnnidPort1SpeedstsLocalread-onlycurrentNID Series card Port1 speed status 10Base-T 100Base-Tx 1000Base-Tx 2.5G
1.3.6.1.4.1.4756.20.500.20.1.44ColumnnidPort1DuplexstsLocalread-onlycurrentNID Series card Port1 duplex status 0: Half 1: Full
1.3.6.1.4.1.4756.20.500.20.1.45ColumnnidPort1RxPausestsLocalread-onlycurrentNID Series card Port1 rx pause status 0: No 1: Yes
1.3.6.1.4.1.4756.20.500.20.1.46ColumnnidPort1TxPausestsLocalread-onlycurrentNID Series card Port1 tx pause status 0: No 1: Yes
1.3.6.1.4.1.4756.20.500.20.1.47ColumnnidPort2LinkstsLocalread-onlycurrentNID Series card Port2 link status: 0:Link down 1:Link up
1.3.6.1.4.1.4756.20.500.20.1.48ColumnnidPort2SpeedstsLocalread-onlycurrentNID Series card Port2 speed status 10Base-T 100Base-Tx 1000Base-Tx 2.5G
1.3.6.1.4.1.4756.20.500.20.1.49ColumnnidPort2DuplexstsLocalread-onlycurrentNID Series card Port2 duplex status 0: Half 1: Full
1.3.6.1.4.1.4756.20.500.20.1.50ColumnnidPort2RxPausestsLocalread-onlycurrentNID Series card Port2 rx pause status 0: No 1: Yes
1.3.6.1.4.1.4756.20.500.20.1.51ColumnnidPort2TxPausestsLocalread-onlycurrentNID Series card Port2 tx pause status 0: No 1: Yes
1.3.6.1.4.1.4756.20.500.20.1.52ColumnnidPort3LinkstsLocalread-onlycurrentNID Series card Port3 link status: 0:Link down 1:Link up
1.3.6.1.4.1.4756.20.500.20.1.53ColumnnidPort3SpeedstsLocalread-onlycurrentNID Series card Port3 speed status 10Base-T 100Base-Tx 1000Base-Tx
1.3.6.1.4.1.4756.20.500.20.1.54ColumnnidPort3DuplexstsLocalread-onlycurrentNID Series card Port3 duplex status 0: Half 1: Full
1.3.6.1.4.1.4756.20.500.20.1.55ColumnnidPort3RxPausestsLocalread-onlycurrentNID Series card Port3 rx pause status 0: No 1: Yes
1.3.6.1.4.1.4756.20.500.20.1.56ColumnnidPort3TxPausestsLocalread-onlycurrentNID Series card Port3 tx pause status 0: No 1: Yes
1.3.6.1.4.1.4756.20.500.20.1.57ColumnnidPort4LinkstsLocalread-onlycurrentNID Series card Port4 link status: 0:Link down 1:Link up
1.3.6.1.4.1.4756.20.500.20.1.58ColumnnidPort4SpeedstsLocalread-onlycurrentNID Series card Port4 speed status 10Base-T 100Base-Tx 1000Base-Tx
1.3.6.1.4.1.4756.20.500.20.1.59ColumnnidPort4DuplexstsLocalread-onlycurrentNID Series card Port4 duplex status 0: Half 1: Full
1.3.6.1.4.1.4756.20.500.20.1.60ColumnnidPort4RxPausestsLocalread-onlycurrentNID Series card Port4 rx pause status 0: No 1: Yes
1.3.6.1.4.1.4756.20.500.20.1.61ColumnnidPort4TxPausestsLocalread-onlycurrentNID Series card Port4 tx pause status 0: No 1: Yes
1.3.6.1.4.1.4756.20.500.20.1.62ColumnnidPort5LinkstsLocalread-onlycurrentNID Series card Port5 link status: 0:Link down 1:Link up
1.3.6.1.4.1.4756.20.500.20.1.63ColumnnidPort5SpeedstsLocalread-onlycurrentNID Series card Port5 speed status 10Base-T 100Base-Tx 1000Base-Tx
1.3.6.1.4.1.4756.20.500.20.1.64ColumnnidPort5DuplexstsLocalread-onlycurrentNID Series card Port5 duplex status 0: Half 1: Full
1.3.6.1.4.1.4756.20.500.20.1.65ColumnnidPort5RxPausestsLocalread-onlycurrentNID Series card Port5 rx pause status 0: No 1: Yes
1.3.6.1.4.1.4756.20.500.20.1.66ColumnnidPort5TxPausestsLocalread-onlycurrentNID Series card Port5 tx pause status 0: No 1: Yes
1.3.6.1.4.1.4756.20.500.20.1.67ColumnnidPort6LinkstsLocalread-onlycurrentNID Series card Port6 link status: 0:Link down 1:Link up
1.3.6.1.4.1.4756.20.500.20.1.68ColumnnidPort6SpeedstsLocalread-onlycurrentNID Series card Port6 speed status 10Base-T 100Base-Tx 1000Base-Tx
1.3.6.1.4.1.4756.20.500.20.1.69ColumnnidPort6DuplexstsLocalread-onlycurrentNID Series card Port6 duplex status 0: Half 1: Full
1.3.6.1.4.1.4756.20.500.20.1.70ColumnnidPort6RxPausestsLocalread-onlycurrentNID Series card Port6 rx pause status 0: No 1: Yes
1.3.6.1.4.1.4756.20.500.20.1.71ColumnnidPort6TxPausestsLocalread-onlycurrentNID Series card Port6 tx pause status 0: No 1: Yes
1.3.6.1.4.1.4756.20.500.20.1.72ColumnnidPort7LinkstsLocalread-onlycurrentNID Series card Port7 link status: 0:Link down 1:Link up
1.3.6.1.4.1.4756.20.500.20.1.73ColumnnidPort7SpeedstsLocalread-onlycurrentNID Series card Port7 speed status 10Base-T 100Base-Tx 1000Base-Tx
1.3.6.1.4.1.4756.20.500.20.1.74ColumnnidPort7DuplexstsLocalread-onlycurrentNID Series card Port7 duplex status 0: Half 1: Full
1.3.6.1.4.1.4756.20.500.20.1.75ColumnnidPort7RxPausestsLocalread-onlycurrentNID Series card Port7 rx pause status 0: No 1: Yes
1.3.6.1.4.1.4756.20.500.20.1.76ColumnnidPort7TxPausestsLocalread-onlycurrentNID Series card Port7 tx pause status 0: No 1: Yes
1.3.6.1.4.1.4756.20.500.20.1.77ColumnnidPort8LinkstsLocalread-onlycurrentNID Series card Port8 link status: 0:Link down 1:Link up
1.3.6.1.4.1.4756.20.500.20.1.78ColumnnidPort8SpeedstsLocalread-onlycurrentNID Series card Port8 speed status 10Base-T 100Base-Tx 1000Base-Tx
1.3.6.1.4.1.4756.20.500.20.1.79ColumnnidPort8DuplexstsLocalread-onlycurrentNID Series card Port8 duplex status 0: Half 1: Full
1.3.6.1.4.1.4756.20.500.20.1.80ColumnnidPort8RxPausestsLocalread-onlycurrentNID Series card Port8 rx pause status 0: No 1: Yes
1.3.6.1.4.1.4756.20.500.20.1.81ColumnnidPort8TxPausestsLocalread-onlycurrentNID Series card Port8 tx pause status 0: No 1: Yes
1.3.6.1.4.1.4756.20.500.20.1.82ColumnnidPort1SpeedConfLocalread-writecurrentNID Series card Port1 speed config 0: disable 1: auto 2: 100M FDX 3: 1G FDX 4: 2.5G FDX
1.3.6.1.4.1.4756.20.500.20.1.83ColumnnidPort1flowConrolLocalread-writecurrentNID Series card Port1 flow control config 0: no 1: yes
1.3.6.1.4.1.4756.20.500.20.1.84ColumnnidPort1MaxFrameLocalread-writecurrentNID Series card Port1 max frame config
1.3.6.1.4.1.4756.20.500.20.1.85ColumnnidPort1ALSLocalread-writecurrentNID Series card Port1 auto laser shutdown: 0: Disable 1: Enable
1.3.6.1.4.1.4756.20.500.20.1.86ColumnnidPort2SpeedConfLocalread-writecurrentNID Series card Port2 speed config 0: disable 1: auto 2: 100M FDX 3: 1G FDX 4: 2.5G FDX
1.3.6.1.4.1.4756.20.500.20.1.87ColumnnidPort2flowConrolLocalread-writecurrentNID Series card Port2 flow control config 0: no 1: yes
1.3.6.1.4.1.4756.20.500.20.1.88ColumnnidPort2MaxFrameLocalread-writecurrentNID Series card Port2 max frame config
1.3.6.1.4.1.4756.20.500.20.1.89ColumnnidPort2ALSLocalread-writecurrentNID Series card Port2 auto laser shutdown: 0: Disable 1: Enable
1.3.6.1.4.1.4756.20.500.20.1.90ColumnnidPort3SpeedConfLocalread-writecurrentNID Series card Port3 speed config 0: disable 1: auto 2: 100M FDX 3: 1G FDX
1.3.6.1.4.1.4756.20.500.20.1.91ColumnnidPort3flowConrolLocalread-writecurrentNID Series card Port3 flow control config 0: no 1: yes
1.3.6.1.4.1.4756.20.500.20.1.92ColumnnidPort3MaxFrameLocalread-writecurrentNID Series card Port3 max frame config
1.3.6.1.4.1.4756.20.500.20.1.93ColumnnidPort3ALSLocalread-writecurrentNID Series card Port3 auto laser shutdown: 0: Disable 1: Enable
1.3.6.1.4.1.4756.20.500.20.1.94ColumnnidPort4SpeedConfLocalread-writecurrentNID Series card Port4 speed config 0: disable 1: auto 2: 100M FDX 3: 1G FDX
1.3.6.1.4.1.4756.20.500.20.1.95ColumnnidPort4flowConrolLocalread-writecurrentNID Series card Port4 flow control config 0: no 1: yes
1.3.6.1.4.1.4756.20.500.20.1.96ColumnnidPort4MaxFrameLocalread-writecurrentNID Series card Port4 max frame config
1.3.6.1.4.1.4756.20.500.20.1.97ColumnnidPort4ALSLocalread-writecurrentNID Series card Port4 auto laser shutdown: 0: Disable 1: Enable
1.3.6.1.4.1.4756.20.500.20.1.98ColumnnidPort5SpeedConfLocalread-writecurrentNID Series card Port5 speed config 0: disable 1: auto 2: 10M HDX 3: 10M FDX 4: 100M HDX 5: 100M FDX 6: 1G FDX
1.3.6.1.4.1.4756.20.500.20.1.99ColumnnidPort5flowConrolLocalread-writecurrentNID Series card Port5 flow control config 0: no 1: yes
1.3.6.1.4.1.4756.20.500.20.1.100ColumnnidPort5MaxFrameLocalread-writecurrentNID Series card Port5 max frame config
1.3.6.1.4.1.4756.20.500.20.1.101ColumnnidPort5CollisionModeLocalread-writecurrentNID Series card Port5 collision mode config. 0: Discard 1: Restart
1.3.6.1.4.1.4756.20.500.20.1.102ColumnnidPort6SpeedConfLocalread-writecurrentNID Series card Port6 speed config 0: disable 1: auto 2: 10M HDX 3: 10M FDX 4: 100M HDX 5: 100M FDX 6: 1G FDX
1.3.6.1.4.1.4756.20.500.20.1.103ColumnnidPort6flowConrolLocalread-writecurrentNID Series card Port6 flow control config 0: no 1: yes
1.3.6.1.4.1.4756.20.500.20.1.104ColumnnidPort6MaxFrameLocalread-writecurrentNID Series card Port6 max frame config
1.3.6.1.4.1.4756.20.500.20.1.105ColumnnidPort6CollisionModeLocalread-writecurrentNID Series card Port6 collision mode config. 0: Discard 1: Restart
1.3.6.1.4.1.4756.20.500.20.1.106ColumnnidPort7SpeedConfLocalread-writecurrentNID Series card Port7 speed config 0: disable 1: auto 2: 10M HDX 3: 10M FDX 4: 100M HDX 5: 100M FDX 6: 1G FDX
1.3.6.1.4.1.4756.20.500.20.1.107ColumnnidPort7flowConrolLocalread-writecurrentNID Series card Port7 flow control config 0: no 1: yes
1.3.6.1.4.1.4756.20.500.20.1.108ColumnnidPort7MaxFrameLocalread-writecurrentNID Series card Port7 max frame config
1.3.6.1.4.1.4756.20.500.20.1.109ColumnnidPort7CollisionModeLocalread-writecurrentNID Series card Port7 collision mode config. 0: Discard 1: Restart
1.3.6.1.4.1.4756.20.500.20.1.110ColumnnidPort8SpeedConfLocalread-writecurrentNID Series card Port8 speed config 0: disable 1: auto 2: 10M HDX 3: 10M FDX 4: 100M HDX 5: 100M FDX 6: 1G FDX
1.3.6.1.4.1.4756.20.500.20.1.111ColumnnidPort8flowConrolLocalread-writecurrentNID Series card Port8 flow control config 0: no 1: yes
1.3.6.1.4.1.4756.20.500.20.1.112ColumnnidPort8MaxFrameLocalread-writecurrentNID Series card Port8 max frame config
1.3.6.1.4.1.4756.20.500.20.1.113ColumnnidPort8CollisionModeLocalread-writecurrentNID Series card Port8 collision mode config. 0: Discard 1: Restart
1.3.6.1.4.1.4756.20.500.20.1.114ColumnnidPort1LLFLogicLocalread-writecurrentNID Series card Port1 link loss forwarding - Logic 0: AND 1: OR
1.3.6.1.4.1.4756.20.500.20.1.115ColumnnidPort1LLFLogicPort2Localread-writecurrentNID Series card Port1 link loss forwarding - Link/Rx Loss Port2 0: NO 1: YES
1.3.6.1.4.1.4756.20.500.20.1.116ColumnnidPort1LLFLogicPort3Localread-writecurrentNID Series card Port1 link loss forwarding - Link/Rx Loss Port3 0: NO 1: YES
1.3.6.1.4.1.4756.20.500.20.1.117ColumnnidPort1LLFLogicPort4Localread-writecurrentNID Series card Port1 link loss forwarding - Link/Rx Loss Port4 0: NO 1: YES
1.3.6.1.4.1.4756.20.500.20.1.118ColumnnidPort1LLFLogicPort5Localread-writecurrentNID Series card Port1 link loss forwarding - Link/Rx Loss Port5 0: NO 1: YES
1.3.6.1.4.1.4756.20.500.20.1.119ColumnnidPort1LLFLogicPort6Localread-writecurrentNID Series card Port1 link loss forwarding - Link/Rx Loss Port6 0: NO 1: YES
1.3.6.1.4.1.4756.20.500.20.1.120ColumnnidPort1LLFLogicPort7Localread-writecurrentNID Series card Port1 link loss forwarding - Link/Rx Loss Port7 0: NO 1: YES
1.3.6.1.4.1.4756.20.500.20.1.121ColumnnidPort1LLFLogicPort8Localread-writecurrentNID Series card Port1 link loss forwarding - Link/Rx Loss Port8 0: NO 1: YES
1.3.6.1.4.1.4756.20.500.20.1.122ColumnnidPort2LLFLogicLocalread-writecurrentNID Series card Port2 link loss forwarding - Logic 0: AND 1: OR
1.3.6.1.4.1.4756.20.500.20.1.123ColumnnidPort2LLFLogicPort1Localread-writecurrentNID Series card Port2 link loss forwarding - Link/Rx Loss Port1 0: NO 1: YES
1.3.6.1.4.1.4756.20.500.20.1.124ColumnnidPort2LLFLogicPort3Localread-writecurrentNID Series card Port2 link loss forwarding - Link/Rx Loss Port3 0: NO 1: YES
1.3.6.1.4.1.4756.20.500.20.1.125ColumnnidPort2LLFLogicPort4Localread-writecurrentNID Series card Port2 link loss forwarding - Link/Rx Loss Port4 0: NO 1: YES
1.3.6.1.4.1.4756.20.500.20.1.126ColumnnidPort2LLFLogicPort5Localread-writecurrentNID Series card Port2 link loss forwarding - Link/Rx Loss Port54 0: NO 1: YES
1.3.6.1.4.1.4756.20.500.20.1.127ColumnnidPort2LLFLogicPort6Localread-writecurrentNID Series card Port2 link loss forwarding - Link/Rx Loss Port6 0: NO 1: YES
1.3.6.1.4.1.4756.20.500.20.1.128ColumnnidPort2LLFLogicPort7Localread-writecurrentNID Series card Port2 link loss forwarding - Link/Rx Loss Port7 0: NO 1: YES
1.3.6.1.4.1.4756.20.500.20.1.129ColumnnidPort2LLFLogicPort8Localread-writecurrentNID Series card Port2 link loss forwarding - Link/Rx Loss Port8 0: NO 1: YES
1.3.6.1.4.1.4756.20.500.20.1.130ColumnnidPort3LLFLogicLocalread-writecurrentNID Series card Port1 link loss forwarding - Logic 0: AND 1: OR
1.3.6.1.4.1.4756.20.500.20.1.131ColumnnidPort3LLFLogicPort1Localread-writecurrentNID Series card Port3 link loss forwarding - Link/Rx Loss Port1 0: NO 1: YES
1.3.6.1.4.1.4756.20.500.20.1.132ColumnnidPort3LLFLogicPort2Localread-writecurrentNID Series card Port3 link loss forwarding - Link/Rx Loss Port2 0: NO 1: YES
1.3.6.1.4.1.4756.20.500.20.1.133ColumnnidPort3LLFLogicPort4Localread-writecurrentNID Series card Port3 link loss forwarding - Link/Rx Loss Port4 0: NO 1: YES
1.3.6.1.4.1.4756.20.500.20.1.134ColumnnidPort3LLFLogicPort5Localread-writecurrentNID Series card Port3 link loss forwarding - Link/Rx Loss Port5 0: NO 1: YES
1.3.6.1.4.1.4756.20.500.20.1.135ColumnnidPort3LLFLogicPort6Localread-writecurrentNID Series card Port3 link loss forwarding - Link/Rx Loss Port6 0: NO 1: YES
1.3.6.1.4.1.4756.20.500.20.1.136ColumnnidPort3LLFLogicPort7Localread-writecurrentNID Series card Port3 link loss forwarding - Link/Rx Loss Port7 0: NO 1: YES
1.3.6.1.4.1.4756.20.500.20.1.137ColumnnidPort3LLFLogicPort8Localread-writecurrentNID Series card Port3 link loss forwarding - Link/Rx Loss Port8 0: NO 1: YES
1.3.6.1.4.1.4756.20.500.20.1.138ColumnnidPort4LLFLogicLocalread-writecurrentNID Series card Port4 link loss forwarding - Logic 0: AND 1: OR
1.3.6.1.4.1.4756.20.500.20.1.139ColumnnidPort4LLFLogicPort1Localread-writecurrentNID Series card Port4 link loss forwarding - Link/Rx Loss Port1 0: NO 1: YES
1.3.6.1.4.1.4756.20.500.20.1.140ColumnnidPort4LLFLogicPort2Localread-writecurrentNID Series card Port4 link loss forwarding - Link/Rx Loss Port2 0: NO 1: YES
1.3.6.1.4.1.4756.20.500.20.1.141ColumnnidPort4LLFLogicPort3Localread-writecurrentNID Series card Port4 link loss forwarding - Link/Rx Loss Port3 0: NO 1: YES
1.3.6.1.4.1.4756.20.500.20.1.142ColumnnidPort4LLFLogicPort5Localread-writecurrentNID Series card Port4 link loss forwarding - Link/Rx Loss Port5 0: NO 1: YES
1.3.6.1.4.1.4756.20.500.20.1.143ColumnnidPort4LLFLogicPort6Localread-writecurrentNID Series card Port4 link loss forwarding - Link/Rx Loss Port6 0: NO 1: YES
1.3.6.1.4.1.4756.20.500.20.1.144ColumnnidPort4LLFLogicPort7Localread-writecurrentNID Series card Port4 link loss forwarding - Link/Rx Loss Port7 0: NO 1: YES
1.3.6.1.4.1.4756.20.500.20.1.145ColumnnidPort4LLFLogicPort8Localread-writecurrentNID Series card Port4 link loss forwarding - Link/Rx Loss Port8 0: NO 1: YES
1.3.6.1.4.1.4756.20.500.20.1.146ColumnnidPort5LLFLogicLocalread-writecurrentNID Series card Port5 link loss forwarding - Logic 0: AND 1: OR
1.3.6.1.4.1.4756.20.500.20.1.147ColumnnidPort5LLFLogicPort1Localread-writecurrentNID Series card Port5 link loss forwarding - Link/Rx Loss Port1 0: NO 1: YES
1.3.6.1.4.1.4756.20.500.20.1.148ColumnnidPort5LLFLogicPort2Localread-writecurrentNID Series card Port5 link loss forwarding - Link/Rx Loss Port2 0: NO 1: YES
1.3.6.1.4.1.4756.20.500.20.1.149ColumnnidPort5LLFLogicPort3Localread-writecurrentNID Series card Port5 link loss forwarding - Link/Rx Loss Port3 0: NO 1: YES
1.3.6.1.4.1.4756.20.500.20.1.150ColumnnidPort5LLFLogicPort4Localread-writecurrentNID Series card Port5 link loss forwarding - Link/Rx Loss Port4 0: NO 1: YES
1.3.6.1.4.1.4756.20.500.20.1.151ColumnnidPort5LLFLogicPort6Localread-writecurrentNID Series card Port5 link loss forwarding - Link/Rx Loss Port6 0: NO 1: YES
1.3.6.1.4.1.4756.20.500.20.1.152ColumnnidPort5LLFLogicPort7Localread-writecurrentNID Series card Port5 link loss forwarding - Link/Rx Loss Port7 0: NO 1: YES
1.3.6.1.4.1.4756.20.500.20.1.153ColumnnidPort5LLFLogicPort8Localread-writecurrentNID Series card Port5 link loss forwarding - Link/Rx Loss Port8 0: NO 1: YES
1.3.6.1.4.1.4756.20.500.20.1.154ColumnnidPort6LLFLogicLocalread-writecurrentNID Series card Port6 link loss forwarding - Logic 0: AND 1: OR
1.3.6.1.4.1.4756.20.500.20.1.155ColumnnidPort6LLFLogicPort1Localread-writecurrentNID Series card Port6 link loss forwarding - Link/Rx Loss Port1 0: NO 1: YES
1.3.6.1.4.1.4756.20.500.20.1.156ColumnnidPort6LLFLogicPort2Localread-writecurrentNID Series card Port6 link loss forwarding - Link/Rx Loss Port2 0: NO 1: YES
1.3.6.1.4.1.4756.20.500.20.1.157ColumnnidPort6LLFLogicPort3Localread-writecurrentNID Series card Port6 link loss forwarding - Link/Rx Loss Port3 0: NO 1: YES
1.3.6.1.4.1.4756.20.500.20.1.158ColumnnidPort6LLFLogicPort4Localread-writecurrentNID Series card Port6 link loss forwarding - Link/Rx Loss Port4 0: NO 1: YES
1.3.6.1.4.1.4756.20.500.20.1.159ColumnnidPort6LLFLogicPort5Localread-writecurrentNID Series card Port6 link loss forwarding - Link/Rx Loss Port5 0: NO 1: YES
1.3.6.1.4.1.4756.20.500.20.1.160ColumnnidPort6LLFLogicPort7Localread-writecurrentNID Series card Port4 link loss forwarding - Link/Rx Loss Port7 0: NO 1: YES
1.3.6.1.4.1.4756.20.500.20.1.161ColumnnidPort6LLFLogicPort8Localread-writecurrentNID Series card Port6 link loss forwarding - Link/Rx Loss Port8 0: NO 1: YES
1.3.6.1.4.1.4756.20.500.20.1.162ColumnnidPort7LLFLogicLocalread-writecurrentNID Series card Port7 link loss forwarding - Logic 0: AND 1: OR
1.3.6.1.4.1.4756.20.500.20.1.163ColumnnidPort7LLFLogicPort1Localread-writecurrentNID Series card Port7 link loss forwarding - Link/Rx Loss Port1 0: NO 1: YES
1.3.6.1.4.1.4756.20.500.20.1.164ColumnnidPort7LLFLogicPort2Localread-writecurrentNID Series card Port7 link loss forwarding - Link/Rx Loss Port2 0: NO 1: YES
1.3.6.1.4.1.4756.20.500.20.1.165ColumnnidPort7LLFLogicPort3Localread-writecurrentNID Series card Port7 link loss forwarding - Link/Rx Loss Port3 0: NO 1: YES
1.3.6.1.4.1.4756.20.500.20.1.166ColumnnidPort7LLFLogicPort4Localread-writecurrentNID Series card Port7 link loss forwarding - Link/Rx Loss Port4 0: NO 1: YES
1.3.6.1.4.1.4756.20.500.20.1.167ColumnnidPort7LLFLogicPort5Localread-writecurrentNID Series card Port7 link loss forwarding - Link/Rx Loss Port5 0: NO 1: YES
1.3.6.1.4.1.4756.20.500.20.1.168ColumnnidPort7LLFLogicPort6Localread-writecurrentNID Series card Port4 link loss forwarding - Link/Rx Loss Port6 0: NO 1: YES
1.3.6.1.4.1.4756.20.500.20.1.169ColumnnidPort7LLFLogicPort8Localread-writecurrentNID Series card Port7 link loss forwarding - Link/Rx Loss Port8 0: NO 1: YES
1.3.6.1.4.1.4756.20.500.20.1.170ColumnnidPort8LLFLogicLocalread-writecurrentNID Series card Port8 link loss forwarding - Logic 0: AND 1: OR
1.3.6.1.4.1.4756.20.500.20.1.171ColumnnidPort8LLFLogicPort1Localread-writecurrentNID Series card Port8 link loss forwarding - Link/Rx Loss Port1 0: NO 1: YES
1.3.6.1.4.1.4756.20.500.20.1.172ColumnnidPort8LLFLogicPort2Localread-writecurrentNID Series card Port8 link loss forwarding - Link/Rx Loss Port2 0: NO 1: YES
1.3.6.1.4.1.4756.20.500.20.1.173ColumnnidPort8LLFLogicPort3Localread-writecurrentNID Series card Port5 link loss forwarding - Link/Rx Loss Port3 0: NO 1: YES
1.3.6.1.4.1.4756.20.500.20.1.174ColumnnidPort8LLFLogicPort4Localread-writecurrentNID Series card Port8 link loss forwarding - Link/Rx Loss Port4 0: NO 1: YES
1.3.6.1.4.1.4756.20.500.20.1.175ColumnnidPort8LLFLogicPort5Localread-writecurrentNID Series card Port8 link loss forwarding - Link/Rx Loss Port5 0: NO 1: YES
1.3.6.1.4.1.4756.20.500.20.1.176ColumnnidPort8LLFLogicPort6Localread-writecurrentNID Series card Port8 link loss forwarding - Link/Rx Loss Port6 0: NO 1: YES
1.3.6.1.4.1.4756.20.500.20.1.177ColumnnidPort8LLFLogicPort7Localread-writecurrentNID Series card Port8 link loss forwarding - Link/Rx Loss Port7 0: NO 1: YES
1.3.6.1.4.1.4756.20.500.20.1.178ColumnnidPort1PacketsRxLocalread-onlycurrentNID Series card port1 traffic overview:: Packets Rx
1.3.6.1.4.1.4756.20.500.20.1.179ColumnnidPort1PacketsTxLocalread-onlycurrentNID Series card port1 traffic overview:: Packets Tx
1.3.6.1.4.1.4756.20.500.20.1.180ColumnnidPort1BytesRxLocalread-onlycurrentNID Series card port1 traffic overview:: Bytes Rx
1.3.6.1.4.1.4756.20.500.20.1.181ColumnnidPort1BytesTxLocalread-onlycurrentNID Series card port1 traffic overview:: Bytes Tx
1.3.6.1.4.1.4756.20.500.20.1.182ColumnnidPort1ErrorsRxLocalread-onlycurrentNID Series card port1 traffic overview:: Errors Rx
1.3.6.1.4.1.4756.20.500.20.1.183ColumnnidPort1ErrorsTxLocalread-onlycurrentNID Series card port1 traffic overview:: Errors Tx
1.3.6.1.4.1.4756.20.500.20.1.184ColumnnidPort1DropsRxLocalread-onlycurrentNID Series card port1 traffic overview:: Drops Rx
1.3.6.1.4.1.4756.20.500.20.1.185ColumnnidPort1DropsTxLocalread-onlycurrentNID Series card port1 traffic overview:: Drops Tx
1.3.6.1.4.1.4756.20.500.20.1.186ColumnnidPort1FilteredRxLocalread-onlycurrentNID Series card port1 traffic overview:: Filtered Rx
1.3.6.1.4.1.4756.20.500.20.1.187ColumnnidPort2PacketsRxLocalread-onlycurrentNID Series card port2 traffic overview:: Packets Rx
1.3.6.1.4.1.4756.20.500.20.1.188ColumnnidPort2PacketsTxLocalread-onlycurrentNID Series card port2 traffic overview:: Packets Tx
1.3.6.1.4.1.4756.20.500.20.1.189ColumnnidPort2BytesRxLocalread-onlycurrentNID Series card port2 traffic overview:: Bytes Rx
1.3.6.1.4.1.4756.20.500.20.1.190ColumnnidPort2BytesTxLocalread-onlycurrentNID Series card port2 traffic overview:: Bytes Tx
1.3.6.1.4.1.4756.20.500.20.1.191ColumnnidPort2ErrorsRxLocalread-onlycurrentNID Series card port2 traffic overview:: Errors Rx
1.3.6.1.4.1.4756.20.500.20.1.192ColumnnidPort2ErrorsTxLocalread-onlycurrentNID Series card port2 traffic overview:: Errors Tx
1.3.6.1.4.1.4756.20.500.20.1.193ColumnnidPort2DropsRxLocalread-onlycurrentNID Series card port2 traffic overview:: Drops Rx
1.3.6.1.4.1.4756.20.500.20.1.194ColumnnidPort2DropsTxLocalread-onlycurrentNID Series card port2 traffic overview:: Drops Tx
1.3.6.1.4.1.4756.20.500.20.1.195ColumnnidPort2FilteredRxLocalread-onlycurrentNID Series card port2 traffic overview:: Filtered Rx
1.3.6.1.4.1.4756.20.500.20.1.196ColumnnidPort3PacketsRxLocalread-onlycurrentNID Series card port3 traffic overview:: Packets Rx
1.3.6.1.4.1.4756.20.500.20.1.197ColumnnidPort3PacketsTxLocalread-onlycurrentNID Series card port3 traffic overview:: Packets Tx
1.3.6.1.4.1.4756.20.500.20.1.198ColumnnidPort3BytesRxLocalread-onlycurrentNID Series card port3 traffic overview:: Bytes Rx
1.3.6.1.4.1.4756.20.500.20.1.199ColumnnidPort3BytesTxLocalread-onlycurrentNID Series card port3 traffic overview:: Bytes Tx
1.3.6.1.4.1.4756.20.500.20.1.200ColumnnidPort3ErrorsRxLocalread-onlycurrentNID Series card port3 traffic overview:: Errors Rx
1.3.6.1.4.1.4756.20.500.20.1.201ColumnnidPort3ErrorsTxLocalread-onlycurrentNID Series card port3 traffic overview:: Errors Tx
1.3.6.1.4.1.4756.20.500.20.1.202ColumnnidPort3DropsRxLocalread-onlycurrentNID Series card port3 traffic overview:: Drops Rx
1.3.6.1.4.1.4756.20.500.20.1.203ColumnnidPort3DropsTxLocalread-onlycurrentNID Series card port3 traffic overview:: Drops Tx
1.3.6.1.4.1.4756.20.500.20.1.204ColumnnidPort3FilteredRxLocalread-onlycurrentNID Series card port3 traffic overview:: Filtered Rx
1.3.6.1.4.1.4756.20.500.20.1.205ColumnnidPort4PacketsRxLocalread-onlycurrentNID Series card port4 traffic overview:: Packets Rx
1.3.6.1.4.1.4756.20.500.20.1.206ColumnnidPort4PacketsTxLocalread-onlycurrentNID Series card port4 traffic overview:: Packets Tx
1.3.6.1.4.1.4756.20.500.20.1.207ColumnnidPort4BytesRxLocalread-onlycurrentNID Series card port4 traffic overview:: Bytes Rx
1.3.6.1.4.1.4756.20.500.20.1.208ColumnnidPort4BytesTxLocalread-onlycurrentNID Series card port4 traffic overview:: Bytes Tx
1.3.6.1.4.1.4756.20.500.20.1.209ColumnnidPort4ErrorsRxLocalread-onlycurrentNID Series card port4 traffic overview:: Errors Rx
1.3.6.1.4.1.4756.20.500.20.1.210ColumnnidPort4ErrorsTxLocalread-onlycurrentNID Series card port4 traffic overview:: Errors Tx
1.3.6.1.4.1.4756.20.500.20.1.211ColumnnidPort4DropsRxLocalread-onlycurrentNID Series card port4 traffic overview:: Drops Rx
1.3.6.1.4.1.4756.20.500.20.1.212ColumnnidPort4DropsTxLocalread-onlycurrentNID Series card port4 traffic overview:: Drops Tx
1.3.6.1.4.1.4756.20.500.20.1.213ColumnnidPort4FilteredRxLocalread-onlycurrentNID Series card port4 traffic overview:: Filtered Rx
1.3.6.1.4.1.4756.20.500.20.1.214ColumnnidPort5PacketsRxLocalread-onlycurrentNID Series card port5 traffic overview:: Packets Rx
1.3.6.1.4.1.4756.20.500.20.1.215ColumnnidPort5PacketsTxLocalread-onlycurrentNID Series card port5 traffic overview:: Packets Tx
1.3.6.1.4.1.4756.20.500.20.1.216ColumnnidPort5BytesRxLocalread-onlycurrentNID Series card port5 traffic overview:: Bytes Rx
1.3.6.1.4.1.4756.20.500.20.1.217ColumnnidPort5BytesTxLocalread-onlycurrentNID Series card port5 traffic overview:: Bytes Tx
1.3.6.1.4.1.4756.20.500.20.1.218ColumnnidPort5ErrorsRxLocalread-onlycurrentNID Series card port5 traffic overview:: Errors Rx
1.3.6.1.4.1.4756.20.500.20.1.219ColumnnidPort5ErrorsTxLocalread-onlycurrentNID Series card port5 traffic overview:: Errors Tx
1.3.6.1.4.1.4756.20.500.20.1.220ColumnnidPort5DropsRxLocalread-onlycurrentNID Series card port5 traffic overview:: Drops Rx
1.3.6.1.4.1.4756.20.500.20.1.221ColumnnidPort5DropsTxLocalread-onlycurrentNID Series card port5 traffic overview:: Drops Tx
1.3.6.1.4.1.4756.20.500.20.1.222ColumnnidPort5FilteredRxLocalread-onlycurrentNID Series card port5 traffic overview:: Filtered Rx
1.3.6.1.4.1.4756.20.500.20.1.223ColumnnidPort6PacketsRxLocalread-onlycurrentNID Series card port6 traffic overview:: Packets Rx
1.3.6.1.4.1.4756.20.500.20.1.224ColumnnidPort6PacketsTxLocalread-onlycurrentNID Series card port6 traffic overview:: Packets Tx
1.3.6.1.4.1.4756.20.500.20.1.225ColumnnidPort6BytesRxLocalread-onlycurrentNID Series card port6 traffic overview:: Bytes Rx
1.3.6.1.4.1.4756.20.500.20.1.226ColumnnidPort6BytesTxLocalread-onlycurrentNID Series card port6 traffic overview:: Bytes Tx
1.3.6.1.4.1.4756.20.500.20.1.227ColumnnidPort6ErrorsRxLocalread-onlycurrentNID Series card port6 traffic overview:: Errors Rx
1.3.6.1.4.1.4756.20.500.20.1.228ColumnnidPort6ErrorsTxLocalread-onlycurrentNID Series card port6 traffic overview:: Errors Tx
1.3.6.1.4.1.4756.20.500.20.1.229ColumnnidPort6DropsRxLocalread-onlycurrentNID Series card port6 traffic overview:: Drops Rx
1.3.6.1.4.1.4756.20.500.20.1.230ColumnnidPort6DropsTxLocalread-onlycurrentNID Series card port6 traffic overview:: Drops Tx
1.3.6.1.4.1.4756.20.500.20.1.231ColumnnidPort6FilteredRxLocalread-onlycurrentNID Series card port6 traffic overview:: Filtered Rx
1.3.6.1.4.1.4756.20.500.20.1.232ColumnnidPort7PacketsRxLocalread-onlycurrentNID Series card port7 traffic overview:: Packets Rx
1.3.6.1.4.1.4756.20.500.20.1.233ColumnnidPort7PacketsTxLocalread-onlycurrentNID Series card port7 traffic overview:: Packets Tx
1.3.6.1.4.1.4756.20.500.20.1.234ColumnnidPort7BytesRxLocalread-onlycurrentNID Series card port7 traffic overview:: Bytes Rx
1.3.6.1.4.1.4756.20.500.20.1.235ColumnnidPort7BytesTxLocalread-onlycurrentNID Series card port7 traffic overview:: Bytes Tx
1.3.6.1.4.1.4756.20.500.20.1.236ColumnnidPort7ErrorsRxLocalread-onlycurrentNID Series card port7 traffic overview:: Errors Rx
1.3.6.1.4.1.4756.20.500.20.1.237ColumnnidPort7ErrorsTxLocalread-onlycurrentNID Series card port7 traffic overview:: Errors Tx
1.3.6.1.4.1.4756.20.500.20.1.238ColumnnidPort7DropsRxLocalread-onlycurrentNID Series card port7 traffic overview:: Drops Rx
1.3.6.1.4.1.4756.20.500.20.1.239ColumnnidPort7DropsTxLocalread-onlycurrentNID Series card port7 traffic overview:: Drops Tx
1.3.6.1.4.1.4756.20.500.20.1.240ColumnnidPort7FilteredRxLocalread-onlycurrentNID Series card port7 traffic overview:: Filtered Rx
1.3.6.1.4.1.4756.20.500.20.1.241ColumnnidPort8PacketsRxLocalread-onlycurrentNID Series card port8 traffic overview:: Packets Rx
1.3.6.1.4.1.4756.20.500.20.1.242ColumnnidPort8PacketsTxLocalread-onlycurrentNID Series card port8 traffic overview:: Packets Tx
1.3.6.1.4.1.4756.20.500.20.1.243ColumnnidPort8BytesRxLocalread-onlycurrentNID Series card port8 traffic overview:: Bytes Rx
1.3.6.1.4.1.4756.20.500.20.1.244ColumnnidPort8BytesTxLocalread-onlycurrentNID Series card port8 traffic overview:: Bytes Tx
1.3.6.1.4.1.4756.20.500.20.1.245ColumnnidPort8ErrorsRxLocalread-onlycurrentNID Series card port8 traffic overview:: Errors Rx
1.3.6.1.4.1.4756.20.500.20.1.246ColumnnidPort8ErrorsTxLocalread-onlycurrentNID Series card port8 traffic overview:: Errors Tx
1.3.6.1.4.1.4756.20.500.20.1.247ColumnnidPort8DropsRxLocalread-onlycurrentNID Series card port8 traffic overview:: Drops Rx
1.3.6.1.4.1.4756.20.500.20.1.248ColumnnidPort8DropsTxLocalread-onlycurrentNID Series card port8 traffic overview:: Drops Tx
1.3.6.1.4.1.4756.20.500.20.1.249ColumnnidPort8FilteredRxLocalread-onlycurrentNID Series card port8 traffic overview:: Filtered Rx
1.3.6.1.4.1.4756.20.500.20.1.250ColumnnidAggrSourceMACAddrLocalread-writecurrentNID Series card Aggregation Mode Configuration: Source MAC Address 0: No 1: Yes
1.3.6.1.4.1.4756.20.500.20.1.251ColumnnidAggrDestinationMACAddrLocalread-writecurrentNID Series card Aggregation Mode Configuration: Destination MAC Address 0: No 1: Yes
1.3.6.1.4.1.4756.20.500.20.1.252ColumnnidAggrIPAddrLocalread-writecurrentNID Series card Aggregation Mode Configuration: IP Address 0: No 1: Yes
1.3.6.1.4.1.4756.20.500.20.1.253ColumnnidAggrTCPUDPPortNumLocalread-writecurrentNID Series card Aggregation Mode Configuration: TCP/UDP Port Number 0: No 1: Yes
1.3.6.1.4.1.4756.20.500.20.1.254ColumnnidAggrGroupPort1ConfLocalread-writecurrentNID Series card Aggregation Group Port1 Configuration: 0: Normal 1: ID1 2: ID2 3: ID3 4: ID4
1.3.6.1.4.1.4756.20.500.20.1.255ColumnnidAggrGroupPort2ConfLocalread-writecurrentNID Series card Aggregation Group Port2 Configuration: 0: Normal 1: ID1 2: ID2 3: ID3 4: ID4
1.3.6.1.4.1.4756.20.500.20.1.256ColumnnidAggrGroupPort3ConfLocalread-writecurrentNID Series card Aggregation Group Port3 Configuration: 0: Normal 1: ID1 2: ID2 3: ID3 4: ID4
1.3.6.1.4.1.4756.20.500.20.1.257ColumnnidAggrGroupPort4ConfLocalread-writecurrentNID Series card Aggregation Group Port4 Configuration: 0: Normal 1: ID1 2: ID2 3: ID3 4: ID4
1.3.6.1.4.1.4756.20.500.20.1.258ColumnnidAggrGroupPort5ConfLocalread-writecurrentNID Series card Aggregation Group Port5 Configuration: 0: Normal 1: ID1 2: ID2 3: ID3 4: ID4
1.3.6.1.4.1.4756.20.500.20.1.259ColumnnidAggrGroupPort6ConfLocalread-writecurrentNID Series card Aggregation Group Port6 Configuration: 0: Normal 1: ID1 2: ID2 3: ID3 4: ID4
1.3.6.1.4.1.4756.20.500.20.1.260ColumnnidAggrGroupPort7ConfLocalread-writecurrentNID Series card Aggregation Group Port7 Configuration: 0: Normal 1: ID1 2: ID2 3: ID3 4: ID4
1.3.6.1.4.1.4756.20.500.20.1.261ColumnnidAggrGroupPort8ConfLocalread-writecurrentNID Series card Aggregation Group Port8 Configuration: 0: Normal 1: ID1 2: ID2 3: ID3 4: ID4
1.3.6.1.4.1.4756.20.500.20.1.262ColumnnidPort1LACPEnabledLocalread-writecurrentNID Series card Port1 LACP Enabled: 0: No 1: Yes
1.3.6.1.4.1.4756.20.500.20.1.263ColumnnidPort1LACPKEYLocalread-writecurrentNID Series card Port1 LACP Key value: The Key value incurred by the port, range 0-65535.The value of 0 means auto.
1.3.6.1.4.1.4756.20.500.20.1.264ColumnnidPort1LACPRoleLocalread-writecurrentNID Series card Port1 LACP Role: 0: Passive 1: Active
1.3.6.1.4.1.4756.20.500.20.1.265ColumnnidPort1LACPTimeOutLocalread-writecurrentNID Series card Port1 LACP Time out: 0: Slow 1: Fast
1.3.6.1.4.1.4756.20.500.20.1.266ColumnnidPort1LACPPrioLocalread-writecurrentNID Series card Port1 LACP priority: The Key value incurred by the port, range 1-65535.
1.3.6.1.4.1.4756.20.500.20.1.267ColumnnidPort2LACPEnabledLocalread-writecurrentNID Series card Port2 LACP Enabled: 0: No 1: Yes
1.3.6.1.4.1.4756.20.500.20.1.268ColumnnidPort2LACPKEYLocalread-writecurrentNID Series card Port2 LACP Key value: The Key value incurred by the port, range 0-65535.The value of 0 means auto.
1.3.6.1.4.1.4756.20.500.20.1.269ColumnnidPort2LACPRoleLocalread-writecurrentNID Series card Port2 LACP Role: 0: Passive 1: Active
1.3.6.1.4.1.4756.20.500.20.1.270ColumnnidPort2LACPTimeOutLocalread-writecurrentNID Series card Port2 LACP Time out: 0: Slow 1: Fast
1.3.6.1.4.1.4756.20.500.20.1.271ColumnnidPort2LACPPrioLocalread-writecurrentNID Series card Port2 LACP priority: The Key value incurred by the port, range 1-65535.
1.3.6.1.4.1.4756.20.500.20.1.272ColumnnidPort3LACPEnabledLocalread-writecurrentNID Series card Port3 LACP Enabled: 0: No 1: Yes
1.3.6.1.4.1.4756.20.500.20.1.273ColumnnidPort3LACPKEYLocalread-writecurrentNID Series card Port3 LACP Key value: The Key value incurred by the port, range 0-65535.The value of 0 means auto.
1.3.6.1.4.1.4756.20.500.20.1.274ColumnnidPort3LACPRoleLocalread-writecurrentNID Series card Port3 LACP Role: 0: Passive 1: Active
1.3.6.1.4.1.4756.20.500.20.1.275ColumnnidPort3LACPTimeOutLocalread-writecurrentNID Series card Port3 LACP Time out: 0: Slow 1: Fast
1.3.6.1.4.1.4756.20.500.20.1.276ColumnnidPort3LACPPrioLocalread-writecurrentNID Series card Port3 LACP priority: The Key value incurred by the port, range 1-65535.
1.3.6.1.4.1.4756.20.500.20.1.277ColumnnidPort4LACPEnabledLocalread-writecurrentNID Series card Port4 LACP Enabled: 0: No 1: Yes
1.3.6.1.4.1.4756.20.500.20.1.278ColumnnidPort4LACPKEYLocalread-writecurrentNID Series card Port4 LACP Key value: The Key value incurred by the port, range 0-65535.The value of 0 means auto.
1.3.6.1.4.1.4756.20.500.20.1.279ColumnnidPort4LACPRoleLocalread-writecurrentNID Series card Port4 LACP Role: 0: Passive 1: Active
1.3.6.1.4.1.4756.20.500.20.1.280ColumnnidPort4LACPTimeOutLocalread-writecurrentNID Series card Port4 LACP Time out: 0: Slow 1: Fast
1.3.6.1.4.1.4756.20.500.20.1.281ColumnnidPort4LACPPrioLocalread-writecurrentNID Series card Port4 LACP priority: The Key value incurred by the port, range 1-65535.
1.3.6.1.4.1.4756.20.500.20.1.282ColumnnidPort5LACPEnabledLocalread-writecurrentNID Series card Port5 LACP Enabled: 0: No 1: Yes
1.3.6.1.4.1.4756.20.500.20.1.283ColumnnidPort5LACPKEYLocalread-writecurrentNID Series card Port5 LACP Key value: The Key value incurred by the port, range 0-65535.The value of 0 means auto.
1.3.6.1.4.1.4756.20.500.20.1.284ColumnnidPort5LACPRoleLocalread-writecurrentNID Series card Port5 LACP Role: 0: Passive 1: Active
1.3.6.1.4.1.4756.20.500.20.1.285ColumnnidPort5LACPTimeOutLocalread-writecurrentNID Series card Port5 LACP Time out: 0: Slow 1: Fast
1.3.6.1.4.1.4756.20.500.20.1.286ColumnnidPort5LACPPrioLocalread-writecurrentNID Series card Port5 LACP priority: The Key value incurred by the port, range 1-65535.
1.3.6.1.4.1.4756.20.500.20.1.287ColumnnidPort6LACPEnabledLocalread-writecurrentNID Series card Port6 LACP Enabled: 0: No 1: Yes
1.3.6.1.4.1.4756.20.500.20.1.288ColumnnidPort6LACPKEYLocalread-writecurrentNID Series card Port6 LACP Key value: The Key value incurred by the port, range 0-65535.The value of 0 means auto.
1.3.6.1.4.1.4756.20.500.20.1.289ColumnnidPort6LACPRoleLocalread-writecurrentNID Series card Port6 LACP Role: 0: Passive 1: Active
1.3.6.1.4.1.4756.20.500.20.1.290ColumnnidPort6LACPTimeOutLocalread-writecurrentNID Series card Port6 LACP Time out: 0: Slow 1: Fast
1.3.6.1.4.1.4756.20.500.20.1.291ColumnnidPort6LACPPrioLocalread-writecurrentNID Series card Port6 LACP priority: The Key value incurred by the port, range 1-65535.
1.3.6.1.4.1.4756.20.500.20.1.292ColumnnidPort7LACPEnabledLocalread-writecurrentNID Series card Port7 LACP Enabled: 0: No 1: Yes
1.3.6.1.4.1.4756.20.500.20.1.293ColumnnidPort7LACPKEYLocalread-writecurrentNID Series card Port7 LACP Key value: The Key value incurred by the port, range 0-65535.The value of 0 means auto.
1.3.6.1.4.1.4756.20.500.20.1.294ColumnnidPort7LACPRoleLocalread-writecurrentNID Series card Port7 LACP Role: 0: Passive 1: Active
1.3.6.1.4.1.4756.20.500.20.1.295ColumnnidPort7LACPTimeOutLocalread-writecurrentNID Series card Port7 LACP Time out: 0: Slow 1: Fast
1.3.6.1.4.1.4756.20.500.20.1.296ColumnnidPort7LACPPrioLocalread-writecurrentNID Series card Port7 LACP priority: The Key value incurred by the port, range 1-65535.
1.3.6.1.4.1.4756.20.500.20.1.297ColumnnidPort8LACPEnabledLocalread-writecurrentNID Series card Port8 LACP Enabled: 0: No 1: Yes
1.3.6.1.4.1.4756.20.500.20.1.298ColumnnidPort8LACPKEYLocalread-writecurrentNID Series card Port8 LACP Key value: The Key value incurred by the port, range 0-65535.The value of 0 means auto.
1.3.6.1.4.1.4756.20.500.20.1.299ColumnnidPort8LACPRoleLocalread-writecurrentNID Series card Port8 LACP Role: 0: Passive 1: Active
1.3.6.1.4.1.4756.20.500.20.1.300ColumnnidPort8LACPTimeOutLocalread-writecurrentNID Series card Port8 LACP Time out: 0: Slow 1: Fast
1.3.6.1.4.1.4756.20.500.20.1.301ColumnnidPort8LACPPrioLocalread-writecurrentNID Series card Port8 LACP priority: The Key value incurred by the port, range 1-65535.
1.3.6.1.4.1.4756.20.500.20.1.302ColumnnidPort1LACPstsLocalread-onlycurrentNID Series card Port1 LACP status: 0: No 1: Yes 2: Standby
1.3.6.1.4.1.4756.20.500.20.1.303ColumnnidPort1LACPKEYstsLocalread-onlycurrentNID Series card Port1 LACP status: Key
1.3.6.1.4.1.4756.20.500.20.1.304ColumnnidPort1LACPAggrIDstsLocalread-onlycurrentNID Series card Port1 LACP status: Aggr ID
1.3.6.1.4.1.4756.20.500.20.1.305ColumnnidPort1LACPParnterSysIDstsLocalread-onlycurrentNID Series card Port1 LACP status: Parnter System ID
1.3.6.1.4.1.4756.20.500.20.1.306ColumnnidPort1LACPParnterPortstsLocalread-onlycurrentNID Series card Port1 LACP status: Parnter Port Status
1.3.6.1.4.1.4756.20.500.20.1.307ColumnnidPort1LACPParnterProistsLocalread-onlycurrentNID Series card Port1 LACP status: Parnter Priority
1.3.6.1.4.1.4756.20.500.20.1.308ColumnnidPort2LACPstsLocalread-onlycurrentNID Series card Port2 LACP status: 0: No 1: Yes 2: Standby
1.3.6.1.4.1.4756.20.500.20.1.309ColumnnidPort2LACPKEYstsLocalread-onlycurrentNID Series card Port2 LACP status: Key
1.3.6.1.4.1.4756.20.500.20.1.310ColumnnidPort2LACPAggrIDstsLocalread-onlycurrentNID Series card Port2 LACP status: Aggr ID
1.3.6.1.4.1.4756.20.500.20.1.311ColumnnidPort2LACPParnterSysIDstsLocalread-onlycurrentNID Series card Port2 LACP status: Parnter System ID
1.3.6.1.4.1.4756.20.500.20.1.312ColumnnidPort2LACPParnterPortstsLocalread-onlycurrentNID Series card Port2 LACP status: Parnter Port Status
1.3.6.1.4.1.4756.20.500.20.1.313ColumnnidPort2LACPParnterProistsLocalread-onlycurrentNID Series card Port2 LACP status: Parnter Priority
1.3.6.1.4.1.4756.20.500.20.1.314ColumnnidPort3LACPstsLocalread-onlycurrentNID Series card Port3 LACP status: 0: No 1: Yes 2: Standby
1.3.6.1.4.1.4756.20.500.20.1.315ColumnnidPort3LACPKEYstsLocalread-onlycurrentNID Series card Port3 LACP status: Key
1.3.6.1.4.1.4756.20.500.20.1.316ColumnnidPort3LACPAggrIDstsLocalread-onlycurrentNID Series card Port3 LACP status: Aggr ID
1.3.6.1.4.1.4756.20.500.20.1.317ColumnnidPort3LACPParnterSysIDstsLocalread-onlycurrentNID Series card Port3 LACP status: Parnter System ID
1.3.6.1.4.1.4756.20.500.20.1.318ColumnnidPort3LACPParnterPortstsLocalread-onlycurrentNID Series card Port3 LACP status: Parnter Port Status
1.3.6.1.4.1.4756.20.500.20.1.319ColumnnidPort3LACPParnterProistsLocalread-onlycurrentNID Series card Port3 LACP status: Parnter Priority
1.3.6.1.4.1.4756.20.500.20.1.320ColumnnidPort4LACPstsLocalread-onlycurrentNID Series card Port4 LACP status: 0: No 1: Yes 2: Standby
1.3.6.1.4.1.4756.20.500.20.1.321ColumnnidPort4LACPKEYstsLocalread-onlycurrentNID Series card Port4 LACP status: Key
1.3.6.1.4.1.4756.20.500.20.1.322ColumnnidPort4LACPAggrIDstsLocalread-onlycurrentNID Series card Port4 LACP status: Aggr ID
1.3.6.1.4.1.4756.20.500.20.1.323ColumnnidPort4LACPParnterSysIDstsLocalread-onlycurrentNID Series card Port4 LACP status: Parnter System ID
1.3.6.1.4.1.4756.20.500.20.1.324ColumnnidPort4LACPParnterPortstsLocalread-onlycurrentNID Series card Port4 LACP status: Parnter Port Status
1.3.6.1.4.1.4756.20.500.20.1.325ColumnnidPort4LACPParnterProistsLocalread-onlycurrentNID Series card Port4 LACP status: Parnter Priority
1.3.6.1.4.1.4756.20.500.20.1.326ColumnnidPort5LACPstsLocalread-onlycurrentNID Series card Port5 LACP status: 0: No 1: Yes 2: Standby
1.3.6.1.4.1.4756.20.500.20.1.327ColumnnidPort5LACPKEYstsLocalread-onlycurrentNID Series card Port5 LACP status: Key
1.3.6.1.4.1.4756.20.500.20.1.328ColumnnidPort5LACPAggrIDstsLocalread-onlycurrentNID Series card Port5 LACP status: Aggr ID
1.3.6.1.4.1.4756.20.500.20.1.329ColumnnidPort5LACPParnterSysIDstsLocalread-onlycurrentNID Series card Port5 LACP status: Parnter System ID
1.3.6.1.4.1.4756.20.500.20.1.330ColumnnidPort5LACPParnterPortstsLocalread-onlycurrentNID Series card Port5 LACP status: Parnter Port Status
1.3.6.1.4.1.4756.20.500.20.1.331ColumnnidPort5LACPParnterProistsLocalread-onlycurrentNID Series card Port5 LACP status: Parnter Priority
1.3.6.1.4.1.4756.20.500.20.1.332ColumnnidPort6LACPstsLocalread-onlycurrentNID Series card Port6 LACP status: 0: No 1: Yes 2: Standby
1.3.6.1.4.1.4756.20.500.20.1.333ColumnnidPort6LACPKEYstsLocalread-onlycurrentNID Series card Port6 LACP status: Key
1.3.6.1.4.1.4756.20.500.20.1.334ColumnnidPort6LACPAggrIDstsLocalread-onlycurrentNID Series card Port6 LACP status: Aggr ID
1.3.6.1.4.1.4756.20.500.20.1.335ColumnnidPort6LACPParnterSysIDstsLocalread-onlycurrentNID Series card Port6 LACP status: Parnter System ID
1.3.6.1.4.1.4756.20.500.20.1.336ColumnnidPort6LACPParnterPortstsLocalread-onlycurrentNID Series card Port6 LACP status: Parnter Port Status
1.3.6.1.4.1.4756.20.500.20.1.337ColumnnidPort6LACPParnterProistsLocalread-onlycurrentNID Series card Port6 LACP status: Parnter Priority
1.3.6.1.4.1.4756.20.500.20.1.338ColumnnidPort7LACPstsLocalread-onlycurrentNID Series card Port7 LACP status: 0: No 1: Yes 2: Standby
1.3.6.1.4.1.4756.20.500.20.1.339ColumnnidPort7LACPKEYstsLocalread-onlycurrentNID Series card Port7 LACP status: Key
1.3.6.1.4.1.4756.20.500.20.1.340ColumnnidPort7LACPAggrIDstsLocalread-onlycurrentNID Series card Port7 LACP status: Aggr ID
1.3.6.1.4.1.4756.20.500.20.1.341ColumnnidPort7LACPParnterSysIDstsLocalread-onlycurrentNID Series card Port7 LACP status: Parnter System ID
1.3.6.1.4.1.4756.20.500.20.1.342ColumnnidPort7LACPParnterPortstsLocalread-onlycurrentNID Series card Port7 LACP status: Parnter Port Status
1.3.6.1.4.1.4756.20.500.20.1.343ColumnnidPort7LACPParnterProistsLocalread-onlycurrentNID Series card Port7 LACP status: Parnter Priority
1.3.6.1.4.1.4756.20.500.20.1.344ColumnnidPort8LACPstsLocalread-onlycurrentNID Series card Port8 LACP status: 0: No 1: Yes 2: Standby
1.3.6.1.4.1.4756.20.500.20.1.345ColumnnidPort8LACPKEYstsLocalread-onlycurrentNID Series card Port8 LACP status: Key
1.3.6.1.4.1.4756.20.500.20.1.346ColumnnidPort8LACPAggrIDstsLocalread-onlycurrentNID Series card Port8 LACP status: Aggr ID
1.3.6.1.4.1.4756.20.500.20.1.347ColumnnidPort8LACPParnterSysIDstsLocalread-onlycurrentNID Series card Port8 LACP status: Parnter System ID
1.3.6.1.4.1.4756.20.500.20.1.348ColumnnidPort8LACPParnterPortstsLocalread-onlycurrentNID Series card Port8 LACP status: Parnter Port Status
1.3.6.1.4.1.4756.20.500.20.1.349ColumnnidPort8LACPParnterProistsLocalread-onlycurrentNID Series card Port8 LACP status: Parnter Priority
1.3.6.1.4.1.4756.20.500.20.1.350ColumnnidOAMPort1EnableLocalread-writecurrentNID Series card Port1 OAM: 0: Off 1: On
1.3.6.1.4.1.4756.20.500.20.1.351ColumnnidOAMPort1ModeLocalread-writecurrentNID Series card Port1 OAM: 0: Passive 1: Active
1.3.6.1.4.1.4756.20.500.20.1.352ColumnnidOAMPort1LoopBackLocalread-writecurrentNID Series card Port1 OAM LoopBack: 0: Off 1: On
1.3.6.1.4.1.4756.20.500.20.1.353ColumnnidOAMPort1LinkMonitorLocalread-writecurrentNID Series card Port1 OAM Link Monitor: 0: Off 1: On
1.3.6.1.4.1.4756.20.500.20.1.354ColumnnidOAMPort1MIBRetrievalLocalread-writecurrentNID Series card Port1 OAM MIB Retrieval: 0: Off 1: On
1.3.6.1.4.1.4756.20.500.20.1.355ColumnnidOAMPort1LoopBackOPLocalread-writecurrentNID Series card Port1 OAM LoopBack operation: 0: Off 1: On
1.3.6.1.4.1.4756.20.500.20.1.356ColumnnidOAMPort2EnableLocalread-writecurrentNID Series card Port2 OAM: 0: Off 1: On
1.3.6.1.4.1.4756.20.500.20.1.357ColumnnidOAMPort2ModeLocalread-writecurrentNID Series card Port2 OAM: 0: Passive 1: Active
1.3.6.1.4.1.4756.20.500.20.1.358ColumnnidOAMPort2LoopBackLocalread-writecurrentNID Series card Port2 OAM LoopBack: 0: Off 1: On
1.3.6.1.4.1.4756.20.500.20.1.359ColumnnidOAMPort2LinkMonitorLocalread-writecurrentNID Series card Port2 OAM Link Monitor: 0: Off 1: On
1.3.6.1.4.1.4756.20.500.20.1.360ColumnnidOAMPort2MIBRetrievalLocalread-writecurrentNID Series card Port2 OAM MIB Retrieval: 0: Off 1: On
1.3.6.1.4.1.4756.20.500.20.1.361ColumnnidOAMPort2LoopBackOPLocalread-writecurrentNID Series card Port2 OAM LoopBack operation: 0: Off 1: On
1.3.6.1.4.1.4756.20.500.20.1.362ColumnnidOAMPort3EnableLocalread-writecurrentNID Series card Port3 OAM: 0: Off 1: On
1.3.6.1.4.1.4756.20.500.20.1.363ColumnnidOAMPort3ModeLocalread-writecurrentNID Series card Port3 OAM: 0: Passive 1: Active
1.3.6.1.4.1.4756.20.500.20.1.364ColumnnidOAMPort3LoopBackLocalread-writecurrentNID Series card Port3 OAM: 0: Off 1: On
1.3.6.1.4.1.4756.20.500.20.1.365ColumnnidOAMPort3LinkMonitorLocalread-writecurrentNID Series card Port3 OAM Link Monitor: 0: Off 1: On
1.3.6.1.4.1.4756.20.500.20.1.366ColumnnidOAMPort3MIBRetrievalLocalread-writecurrentNID Series card Port3 OAM MIB Retrieval: 0: Off 1: On
1.3.6.1.4.1.4756.20.500.20.1.367ColumnnidOAMPort3LoopBackOPLocalread-writecurrentNID Series card Port3 OAM LoopBack operation: 0: Disable 1: Enable
1.3.6.1.4.1.4756.20.500.20.1.368ColumnnidOAMPort4EnableLocalread-writecurrentNID Series card Port4 OAM: 0: Off 1: On
1.3.6.1.4.1.4756.20.500.20.1.369ColumnnidOAMPort4ModeLocalread-writecurrentNID Series card Port4 OAM: 0: Passive 1: Active
1.3.6.1.4.1.4756.20.500.20.1.370ColumnnidOAMPort4LoopBackLocalread-writecurrentNID Series card Port4 OAM: 0: Off 1: On
1.3.6.1.4.1.4756.20.500.20.1.371ColumnnidOAMPort4LinkMonitorLocalread-writecurrentNID Series card Port4 OAM Link Monitor: 0: Off 1: On
1.3.6.1.4.1.4756.20.500.20.1.372ColumnnidOAMPort4MIBRetrievalLocalread-writecurrentNID Series card Port4 OAM MIB Retrieval: 0: Off 1: On
1.3.6.1.4.1.4756.20.500.20.1.373ColumnnidOAMPort4LoopBackOPLocalread-writecurrentNID Series card Port4 OAM LoopBack operation: 0: On 1: Off
1.3.6.1.4.1.4756.20.500.20.1.374ColumnnidOAMPort5EnableLocalread-writecurrentNID Series card Port5 OAM: 0: Off 1: On
1.3.6.1.4.1.4756.20.500.20.1.375ColumnnidOAMPort5ModeLocalread-writecurrentNID Series card Port5 OAM: 0: Passive 1: Active
1.3.6.1.4.1.4756.20.500.20.1.376ColumnnidOAMPort5LoopBackLocalread-writecurrentNID Series card Port5 OAM: 0: Off 1: On
1.3.6.1.4.1.4756.20.500.20.1.377ColumnnidOAMPort5LinkMonitorLocalread-writecurrentNID Series card Port5 OAM Link Monitor: 0: Off 1: On
1.3.6.1.4.1.4756.20.500.20.1.378ColumnnidOAMPort5MIBRetrievalLocalread-writecurrentNID Series card Port5 OAM MIB Retrieval: 0: Off 1: On
1.3.6.1.4.1.4756.20.500.20.1.379ColumnnidOAMPort5LoopBackOPLocalread-writecurrentNID Series card Port5 OAM LoopBack operation: 0: On 1: Off
1.3.6.1.4.1.4756.20.500.20.1.380ColumnnidOAMPort6EnableLocalread-writecurrentNID Series card Port6 OAM: 0: Off 1: On
1.3.6.1.4.1.4756.20.500.20.1.381ColumnnidOAMPort6ModeLocalread-writecurrentNID Series card Port6 OAM: 0: Passive 1: Active
1.3.6.1.4.1.4756.20.500.20.1.382ColumnnidOAMPort6LoopBackLocalread-writecurrentNID Series card Port6 OAM: 0: Off 1: On
1.3.6.1.4.1.4756.20.500.20.1.383ColumnnidOAMPort6LinkMonitorLocalread-writecurrentNID Series card Port6 OAM Link Monitor: 0: Off 1: On
1.3.6.1.4.1.4756.20.500.20.1.384ColumnnidOAMPort6MIBRetrievalLocalread-writecurrentNID Series card Port6 OAM MIB Retrieval: 0: Off 1: On
1.3.6.1.4.1.4756.20.500.20.1.385ColumnnidOAMPort6LoopBackOPLocalread-writecurrentNID Series card Port6 OAM LoopBack operation: 0: On 1: Off
1.3.6.1.4.1.4756.20.500.20.1.386ColumnnidOAMPort7EnableLocalread-writecurrentNID Series card Port7 OAM: 0: Off 1: On
1.3.6.1.4.1.4756.20.500.20.1.387ColumnnidOAMPort7ModeLocalread-writecurrentNID Series card Port7 OAM: 0: Passive 1: Active
1.3.6.1.4.1.4756.20.500.20.1.388ColumnnidOAMPort7LoopBackLocalread-writecurrentNID Series card Port7 OAM: 0: Off 1: On
1.3.6.1.4.1.4756.20.500.20.1.389ColumnnidOAMPort7LinkMonitorLocalread-writecurrentNID Series card Port7 OAM Link Monitor: 0: Off 1: On
1.3.6.1.4.1.4756.20.500.20.1.390ColumnnidOAMPort7MIBRetrievalLocalread-writecurrentNID Series card Port7 OAM MIB Retrieval: 0: Off 1: On
1.3.6.1.4.1.4756.20.500.20.1.391ColumnnidOAMPort7LoopBackOPLocalread-writecurrentNID Series card Port7 OAM LoopBack operation: 0: On 1: Off
1.3.6.1.4.1.4756.20.500.20.1.392ColumnnidOAMPort8EnableLocalread-writecurrentNID Series card Port8 OAM: 0: Off 1: On
1.3.6.1.4.1.4756.20.500.20.1.393ColumnnidOAMPort8ModeLocalread-writecurrentNID Series card Port8 OAM: 0: Passive 1: Active
1.3.6.1.4.1.4756.20.500.20.1.394ColumnnidOAMPort8LoopBackLocalread-writecurrentNID Series card Port8 OAM: 0: Off 1: On
1.3.6.1.4.1.4756.20.500.20.1.395ColumnnidOAMPort8LinkMonitorLocalread-writecurrentNID Series card Port8 OAM Link Monitor: 0: Off 1: On
1.3.6.1.4.1.4756.20.500.20.1.396ColumnnidOAMPort8MIBRetrievalLocalread-writecurrentNID Series card Port8 OAM MIB Retrieval: 0: Off 1: On
1.3.6.1.4.1.4756.20.500.20.1.397ColumnnidOAMPort8LoopBackOPLocalread-writecurrentNID Series card Port8 OAM LoopBack operation: 0: On 1: Off
1.3.6.1.4.1.4756.20.500.20.1.398ColumnnidPort1EFEErrorWindowLocalread-writecurrentNID Series card Port1 Link Event Configuration: Error Frame Event - Error Window
1.3.6.1.4.1.4756.20.500.20.1.399ColumnnidPort1EFEErrorThresholdLocalread-writecurrentNID Series card Port1 Link Event Configuration: Error Frame Event - Error Threshold
1.3.6.1.4.1.4756.20.500.20.1.400ColumnnidPort1SPEEErrorWindowLocalread-writecurrentNID Series card Port1 Link Event Configuration: Symbol Period Error Event - Error Window
1.3.6.1.4.1.4756.20.500.20.1.401ColumnnidPort1SPEEErrorThresholdLocalread-writecurrentNID Series card Port1 Link Event Configuration: Symbol Period Error Event - Error Threshold
1.3.6.1.4.1.4756.20.500.20.1.402ColumnnidPort1SSEErrorWindowLocalread-writecurrentNID Series card Port1 Link Event Configuration: Seconds Summary Event - Error Window
1.3.6.1.4.1.4756.20.500.20.1.403ColumnnidPort1SSEErrorThresholdLocalread-writecurrentNID Series card Port1 Link Event Configuration: Seconds Summary Event - Error Threshold
1.3.6.1.4.1.4756.20.500.20.1.404ColumnnidPort2EFEErrorWindowLocalread-writecurrentNID Series card Port2 Link Event Configuration: Error Frame Event - Error Window
1.3.6.1.4.1.4756.20.500.20.1.405ColumnnidPort2EFEErrorThresholdLocalread-writecurrentNID Series card Port2 Link Event Configuration: Error Frame Event - Error Threshold
1.3.6.1.4.1.4756.20.500.20.1.406ColumnnidPort2SPEEErrorWindowLocalread-writecurrentNID Series card Port2 Link Event Configuration: Symbol Period Error Event - Error Window
1.3.6.1.4.1.4756.20.500.20.1.407ColumnnidPort2SPEEErrorThresholdLocalread-writecurrentNID Series card Port2 Link Event Configuration: Symbol Period Error Event - Error Threshold
1.3.6.1.4.1.4756.20.500.20.1.408ColumnnidPort2SSEErrorWindowLocalread-writecurrentNID Series card Port2 Link Event Configuration: Seconds Summary Event - Error Window
1.3.6.1.4.1.4756.20.500.20.1.409ColumnnidPort2SSEErrorThresholdLocalread-writecurrentNID Series card Port2 Link Event Configuration: Seconds Summary Event - Error Threshold
1.3.6.1.4.1.4756.20.500.20.1.410ColumnnidPort3EFEErrorWindowLocalread-writecurrentNID Series card Port3 Link Event Configuration: Error Frame Event - Error Window
1.3.6.1.4.1.4756.20.500.20.1.411ColumnnidPort3EFEErrorThresholdLocalread-writecurrentNID Series card Port3 Link Event Configuration: Error Frame Event - Error Threshold
1.3.6.1.4.1.4756.20.500.20.1.412ColumnnidPort3SPEEErrorWindowLocalread-writecurrentNID Series card Port3 Link Event Configuration: Symbol Period Error Event - Error Window
1.3.6.1.4.1.4756.20.500.20.1.413ColumnnidPort3SPEEErrorThresholdLocalread-writecurrentNID Series card Port3 Link Event Configuration: Symbol Period Error Event - Error Threshold
1.3.6.1.4.1.4756.20.500.20.1.414ColumnnidPort3SSEErrorWindowLocalread-writecurrentNID Series card Port3 Link Event Configuration: Seconds Summary Event - Error Window
1.3.6.1.4.1.4756.20.500.20.1.415ColumnnidPort3SSEErrorThresholdLocalread-writecurrentNID Series card Port3 Link Event Configuration: Seconds Summary Event - Error Threshold
1.3.6.1.4.1.4756.20.500.20.1.416ColumnnidPort4EFEErrorWindowLocalread-writecurrentNID Series card Port4 Link Event Configuration: Error Frame Event - Error Window
1.3.6.1.4.1.4756.20.500.20.1.417ColumnnidPort4EFEErrorThresholdLocalread-writecurrentNID Series card Port4 Link Event Configuration: Error Frame Event - Error Threshold
1.3.6.1.4.1.4756.20.500.20.1.418ColumnnidPort4SPEEErrorWindowLocalread-writecurrentNID Series card Port4 Link Event Configuration: Symbol Period Error Event - Error Window
1.3.6.1.4.1.4756.20.500.20.1.419ColumnnidPort4SPEEErrorThresholdLocalread-writecurrentNID Series card Port4 Link Event Configuration: Symbol Period Error Event - Error Threshold
1.3.6.1.4.1.4756.20.500.20.1.420ColumnnidPort4SSEErrorWindowLocalread-writecurrentNID Series card Port4 Link Event Configuration: Seconds Summary Event - Error Window
1.3.6.1.4.1.4756.20.500.20.1.421ColumnnidPort4SSEErrorThresholdLocalread-writecurrentNID Series card Port4 Link Event Configuration: Seconds Summary Event - Error Threshold
1.3.6.1.4.1.4756.20.500.20.1.422ColumnnidPort5EFEErrorWindowLocalread-writecurrentNID Series card Port5 Link Event Configuration: Error Frame Event - Error Window
1.3.6.1.4.1.4756.20.500.20.1.423ColumnnidPort5EFEErrorThresholdLocalread-writecurrentNID Series card Port5 Link Event Configuration: Error Frame Event - Error Threshold
1.3.6.1.4.1.4756.20.500.20.1.424ColumnnidPort5SPEEErrorWindowLocalread-writecurrentNID Series card Port5 Link Event Configuration: Symbol Period Error Event - Error Window
1.3.6.1.4.1.4756.20.500.20.1.425ColumnnidPort5SPEEErrorThresholdLocalread-writecurrentNID Series card Port5 Link Event Configuration: Symbol Period Error Event - Error Threshold
1.3.6.1.4.1.4756.20.500.20.1.426ColumnnidPort5SSEErrorWindowLocalread-writecurrentNID Series card Port5 Link Event Configuration: Seconds Summary Event - Error Window
1.3.6.1.4.1.4756.20.500.20.1.427ColumnnidPort5SSEErrorThresholdLocalread-writecurrentNID Series card Port5 Link Event Configuration: Seconds Summary Event - Error Threshold
1.3.6.1.4.1.4756.20.500.20.1.428ColumnnidPort6EFEErrorWindowLocalread-writecurrentNID Series card Port6 Link Event Configuration: Error Frame Event - Error Window
1.3.6.1.4.1.4756.20.500.20.1.429ColumnnidPort6EFEErrorThresholdLocalread-writecurrentNID Series card Port6 Link Event Configuration: Error Frame Event - Error Threshold
1.3.6.1.4.1.4756.20.500.20.1.430ColumnnidPort6SPEEErrorWindowLocalread-writecurrentNID Series card Port6 Link Event Configuration: Symbol Period Error Event - Error Window
1.3.6.1.4.1.4756.20.500.20.1.431ColumnnidPort6SPEEErrorThresholdLocalread-writecurrentNID Series card Port6 Link Event Configuration: Symbol Period Error Event - Error Threshold
1.3.6.1.4.1.4756.20.500.20.1.432ColumnnidPort6SSEErrorWindowLocalread-writecurrentNID Series card Port6 Link Event Configuration: Seconds Summary Event - Error Window
1.3.6.1.4.1.4756.20.500.20.1.433ColumnnidPort6SSEErrorThresholdLocalread-writecurrentNID Series card Port6 Link Event Configuration: Seconds Summary Event - Error Threshold
1.3.6.1.4.1.4756.20.500.20.1.434ColumnnidPort7EFEErrorWindowLocalread-writecurrentNID Series card Port7 Link Event Configuration: Error Frame Event - Error Window
1.3.6.1.4.1.4756.20.500.20.1.435ColumnnidPort7EFEErrorThresholdLocalread-writecurrentNID Series card Port7 Link Event Configuration: Error Frame Event - Error Threshold
1.3.6.1.4.1.4756.20.500.20.1.436ColumnnidPort7SPEEErrorWindowLocalread-writecurrentNID Series card Port7 Link Event Configuration: Symbol Period Error Event - Error Window
1.3.6.1.4.1.4756.20.500.20.1.437ColumnnidPort7SPEEErrorThresholdLocalread-writecurrentNID Series card Port7 Link Event Configuration: Symbol Period Error Event - Error Threshold
1.3.6.1.4.1.4756.20.500.20.1.438ColumnnidPort7SSEErrorWindowLocalread-writecurrentNID Series card Port7 Link Event Configuration: Seconds Summary Event - Error Window
1.3.6.1.4.1.4756.20.500.20.1.439ColumnnidPort7SSEErrorThresholdLocalread-writecurrentNID Series card Port7 Link Event Configuration: Seconds Summary Event - Error Threshold
1.3.6.1.4.1.4756.20.500.20.1.440ColumnnidPort8EFEErrorWindowLocalread-writecurrentNID Series card Port8 Link Event Configuration: Error Frame Event - Error Window
1.3.6.1.4.1.4756.20.500.20.1.441ColumnnidPort8EFEErrorThresholdLocalread-writecurrentNID Series card Port8 Link Event Configuration: Error Frame Event - Error Threshold
1.3.6.1.4.1.4756.20.500.20.1.442ColumnnidPort8SPEEErrorWindowLocalread-writecurrentNID Series card Port8 Link Event Configuration: Symbol Period Error Event - Error Window
1.3.6.1.4.1.4756.20.500.20.1.443ColumnnidPort8SPEEErrorThresholdLocalread-writecurrentNID Series card Port8 Link Event Configuration: Symbol Period Error Event - Error Threshold
1.3.6.1.4.1.4756.20.500.20.1.444ColumnnidPort8SSEErrorWindowLocalread-writecurrentNID Series card Port8 Link Event Configuration: Seconds Summary Event - Error Window
1.3.6.1.4.1.4756.20.500.20.1.445ColumnnidPort8SSEErrorThresholdLocalread-writecurrentNID Series card Port8 Link Event Configuration: Seconds Summary Event - Error Threshold
1.3.6.1.4.1.4756.20.500.20.1.446ColumnnidPort1RxOAMInfoPDULocalread-onlycurrentNID Series card Port1 Detailed Link OAM Statistics: Rx OAM Information PDU's
1.3.6.1.4.1.4756.20.500.20.1.447ColumnnidPort1RxUniqueErrorEventLocalread-onlycurrentNID Series card Port1 Detailed Link OAM Statistics: Rx Unique Error Event Notificatio
1.3.6.1.4.1.4756.20.500.20.1.448ColumnnidPort1RxDuplicateErrorEventLocalread-onlycurrentNID Series card Port1 Detailed Link OAM Statistics: Rx Duplicate Error Event Notification
1.3.6.1.4.1.4756.20.500.20.1.449ColumnnidPort1RxLoopBackControlLocalread-onlycurrentNID Series card Port1 Detailed Link OAM Statistics: Rx Loopback Control
1.3.6.1.4.1.4756.20.500.20.1.450ColumnnidPort1RxVariableRequestLocalread-onlycurrentNID Series card Port1 Detailed Link OAM Statistics: Rx Variable Request
1.3.6.1.4.1.4756.20.500.20.1.451ColumnnidPort1RxVariableResponseLocalread-onlycurrentNID Series card Port1 Detailed Link OAM Statistics: Rx Variable Response
1.3.6.1.4.1.4756.20.500.20.1.452ColumnnidPort1RxOrgSpecificPDULocalread-onlycurrentNID Series card Port1 Detailed Link OAM Statistics: Rx Org Specific PDU's
1.3.6.1.4.1.4756.20.500.20.1.453ColumnnidPort1RxUnsupportedCodesLocalread-onlycurrentNID Series card Port1 Detailed Link OAM Statistics: Rx Unsupported Codes
1.3.6.1.4.1.4756.20.500.20.1.454ColumnnidPort1RxLinkFaultPDULocalread-onlycurrentNID Series card Port1 Detailed Link OAM Statistics: Rx Link Fault PDU's
1.3.6.1.4.1.4756.20.500.20.1.455ColumnnidPort1RxDyingGaspLocalread-onlycurrentNID Series card Port1 Detailed Link OAM Statistics: Rx Dying Gasp
1.3.6.1.4.1.4756.20.500.20.1.456ColumnnidPort1RxCriticalEventPDULocalread-onlycurrentNID Series card Port1 Detailed Link OAM Statistics: Rx Dying Gasp
1.3.6.1.4.1.4756.20.500.20.1.457ColumnnidPort1TxOAMInfoPDULocalread-onlycurrentNID Series card Port1 Detailed Link OAM Statistics: Tx OAM Information PDU's
1.3.6.1.4.1.4756.20.500.20.1.458ColumnnidPort1TxUniqueErrorEventLocalread-onlycurrentNID Series card Port1 Detailed Link OAM Statistics: Tx Unique Error Event Notificatio
1.3.6.1.4.1.4756.20.500.20.1.459ColumnnidPort1TxDuplicateErrorEventLocalread-onlycurrentNID Series card Port1 Detailed Link OAM Statistics: Tx Duplicate Error Event Notification
1.3.6.1.4.1.4756.20.500.20.1.460ColumnnidPort1TxLoopBackControlLocalread-onlycurrentNID Series card Port1 Detailed Link OAM Statistics: Tx Loopback Control
1.3.6.1.4.1.4756.20.500.20.1.461ColumnnidPort1TxVariableRequestLocalread-onlycurrentNID Series card Port1 Detailed Link OAM Statistics: Tx Variable Request
1.3.6.1.4.1.4756.20.500.20.1.462ColumnnidPort1TxVariableResponseLocalread-onlycurrentNID Series card Port1 Detailed Link OAM Statistics: Tx Variable Response
1.3.6.1.4.1.4756.20.500.20.1.463ColumnnidPort1TxOrgSpecificPDULocalread-onlycurrentNID Series card Port1 Detailed Link OAM Statistics: Tx Org Specific PDU's
1.3.6.1.4.1.4756.20.500.20.1.464ColumnnidPort1TxUnsupportedCodesLocalread-onlycurrentNID Series card Port1 Detailed Link OAM Statistics: Tx Unsupported Codes
1.3.6.1.4.1.4756.20.500.20.1.465ColumnnidPort1TxLinkFaultPDULocalread-onlycurrentNID Series card Port1 Detailed Link OAM Statistics: Tx Link Fault PDU's
1.3.6.1.4.1.4756.20.500.20.1.466ColumnnidPort1TxDyingGaspLocalread-onlycurrentNID Series card Port1 Detailed Link OAM Statistics: Tx Dying Gasp
1.3.6.1.4.1.4756.20.500.20.1.467ColumnnidPort1TxCriticalEventPDULocalread-onlycurrentNID Series card Port1 Detailed Link OAM Statistics: Tx Dying Gasp
1.3.6.1.4.1.4756.20.500.20.1.468ColumnnidPort2RxOAMInfoPDULocalread-onlycurrentNID Series card Port2 Detailed Link OAM Statistics: Rx OAM Information PDU's
1.3.6.1.4.1.4756.20.500.20.1.469ColumnnidPort2RxUniqueErrorEventLocalread-onlycurrentNID Series card Port2 Detailed Link OAM Statistics: Rx Unique Error Event Notificatio
1.3.6.1.4.1.4756.20.500.20.1.470ColumnnidPort2RxDuplicateErrorEventLocalread-onlycurrentNID Series card Port2 Detailed Link OAM Statistics: Rx Duplicate Error Event Notification
1.3.6.1.4.1.4756.20.500.20.1.471ColumnnidPort2RxLoopBackControlLocalread-onlycurrentNID Series card Port2 Detailed Link OAM Statistics: Rx Loopback Control
1.3.6.1.4.1.4756.20.500.20.1.472ColumnnidPort2RxVariableRequestLocalread-onlycurrentNID Series card Port2 Detailed Link OAM Statistics: Rx Variable Request
1.3.6.1.4.1.4756.20.500.20.1.473ColumnnidPort2RxVariableResponseLocalread-onlycurrentNID Series card Port2 Detailed Link OAM Statistics: Rx Variable Response
1.3.6.1.4.1.4756.20.500.20.1.474ColumnnidPort2RxOrgSpecificPDULocalread-onlycurrentNID Series card Port2 Detailed Link OAM Statistics: Rx Org Specific PDU's
1.3.6.1.4.1.4756.20.500.20.1.475ColumnnidPort2RxUnsupportedCodesLocalread-onlycurrentNID Series card Port2 Detailed Link OAM Statistics: Rx Unsupported Codes
1.3.6.1.4.1.4756.20.500.20.1.476ColumnnidPort2RxLinkFaultPDULocalread-onlycurrentNID Series card Port2 Detailed Link OAM Statistics: Rx Link Fault PDU's
1.3.6.1.4.1.4756.20.500.20.1.477ColumnnidPort2RxDyingGaspLocalread-onlycurrentNID Series card Port2 Detailed Link OAM Statistics: Rx Dying Gasp
1.3.6.1.4.1.4756.20.500.20.1.478ColumnnidPort2RxCriticalEventPDULocalread-onlycurrentNID Series card Port2 Detailed Link OAM Statistics: Rx Dying Gasp
1.3.6.1.4.1.4756.20.500.20.1.479ColumnnidPort2TxOAMInfoPDULocalread-onlycurrentNID Series card Port2 Detailed Link OAM Statistics: Tx OAM Information PDU's
1.3.6.1.4.1.4756.20.500.20.1.480ColumnnidPort2TxUniqueErrorEventLocalread-onlycurrentNID Series card Port2 Detailed Link OAM Statistics: Tx Unique Error Event Notificatio
1.3.6.1.4.1.4756.20.500.20.1.481ColumnnidPort2TxDuplicateErrorEventLocalread-onlycurrentNID Series card Port2 Detailed Link OAM Statistics: Tx Duplicate Error Event Notification
1.3.6.1.4.1.4756.20.500.20.1.482ColumnnidPort2TxLoopBackControlLocalread-onlycurrentNID Series card Port2 Detailed Link OAM Statistics: Tx Loopback Control
1.3.6.1.4.1.4756.20.500.20.1.483ColumnnidPort2TxVariableRequestLocalread-onlycurrentNID Series card Port2 Detailed Link OAM Statistics: Tx Variable Request
1.3.6.1.4.1.4756.20.500.20.1.484ColumnnidPort2TxVariableResponseLocalread-onlycurrentNID Series card Port2 Detailed Link OAM Statistics: Tx Variable Response
1.3.6.1.4.1.4756.20.500.20.1.485ColumnnidPort2TxOrgSpecificPDULocalread-onlycurrentNID Series card Port2 Detailed Link OAM Statistics: Tx Org Specific PDU's
1.3.6.1.4.1.4756.20.500.20.1.486ColumnnidPort2TxUnsupportedCodesLocalread-onlycurrentNID Series card Port2 Detailed Link OAM Statistics: Tx Unsupported Codes
1.3.6.1.4.1.4756.20.500.20.1.487ColumnnidPort2TxLinkFaultPDULocalread-onlycurrentNID Series card Port2 Detailed Link OAM Statistics: Tx Link Fault PDU's
1.3.6.1.4.1.4756.20.500.20.1.488ColumnnidPort2TxDyingGaspLocalread-onlycurrentNID Series card Port2 Detailed Link OAM Statistics: Tx Dying Gasp
1.3.6.1.4.1.4756.20.500.20.1.489ColumnnidPort2TxCriticalEventPDULocalread-onlycurrentNID Series card Port2 Detailed Link OAM Statistics: Tx Dying Gasp
1.3.6.1.4.1.4756.20.500.20.1.490ColumnnidPort3RxOAMInfoPDULocalread-onlycurrentNID Series card Port3 Detailed Link OAM Statistics: Rx OAM Information PDU's
1.3.6.1.4.1.4756.20.500.20.1.491ColumnnidPort3RxUniqueErrorEventLocalread-onlycurrentNID Series card Port3 Detailed Link OAM Statistics: Rx Unique Error Event Notificatio
1.3.6.1.4.1.4756.20.500.20.1.492ColumnnidPort3RxDuplicateErrorEventLocalread-onlycurrentNID Series card Port3 Detailed Link OAM Statistics: Rx Duplicate Error Event Notification
1.3.6.1.4.1.4756.20.500.20.1.493ColumnnidPort3RxLoopBackControlLocalread-onlycurrentNID Series card Port3 Detailed Link OAM Statistics: Rx Loopback Control
1.3.6.1.4.1.4756.20.500.20.1.494ColumnnidPort3RxVariableRequestLocalread-onlycurrentNID Series card Port3 Detailed Link OAM Statistics: Rx Variable Request
1.3.6.1.4.1.4756.20.500.20.1.495ColumnnidPort3RxVariableResponseLocalread-onlycurrentNID Series card Port3 Detailed Link OAM Statistics: Rx Variable Response
1.3.6.1.4.1.4756.20.500.20.1.496ColumnnidPort3RxOrgSpecificPDULocalread-onlycurrentNID Series card Port3 Detailed Link OAM Statistics: Rx Org Specific PDU's
1.3.6.1.4.1.4756.20.500.20.1.497ColumnnidPort3RxUnsupportedCodesLocalread-onlycurrentNID Series card Port3 Detailed Link OAM Statistics: Rx Unsupported Codes
1.3.6.1.4.1.4756.20.500.20.1.498ColumnnidPort3RxLinkFaultPDULocalread-onlycurrentNID Series card Port3 Detailed Link OAM Statistics: Rx Link Fault PDU's
1.3.6.1.4.1.4756.20.500.20.1.499ColumnnidPort3RxDyingGaspLocalread-onlycurrentNID Series card Port3 Detailed Link OAM Statistics: Rx Dying Gasp
1.3.6.1.4.1.4756.20.500.20.1.500ColumnnidPort3RxCriticalEventPDULocalread-onlycurrentNID Series card Port3 Detailed Link OAM Statistics: Rx Dying Gasp
1.3.6.1.4.1.4756.20.500.20.1.501ColumnnidPort3TxOAMInfoPDULocalread-onlycurrentNID Series card Port3 Detailed Link OAM Statistics: Tx OAM Information PDU's
1.3.6.1.4.1.4756.20.500.20.1.502ColumnnidPort3TxUniqueErrorEventLocalread-onlycurrentNID Series card Port3 Detailed Link OAM Statistics: Tx Unique Error Event Notificatio
1.3.6.1.4.1.4756.20.500.20.1.503ColumnnidPort3TxDuplicateErrorEventLocalread-onlycurrentNID Series card Port3 Detailed Link OAM Statistics: Tx Duplicate Error Event Notification
1.3.6.1.4.1.4756.20.500.20.1.504ColumnnidPort3TxLoopBackControlLocalread-onlycurrentNID Series card Port3 Detailed Link OAM Statistics: Tx Loopback Control
1.3.6.1.4.1.4756.20.500.20.1.505ColumnnidPort3TxVariableRequestLocalread-onlycurrentNID Series card Port3 Detailed Link OAM Statistics: Tx Variable Request
1.3.6.1.4.1.4756.20.500.20.1.506ColumnnidPort3TxVariableResponseLocalread-onlycurrentNID Series card Port3 Detailed Link OAM Statistics: Tx Variable Response
1.3.6.1.4.1.4756.20.500.20.1.507ColumnnidPort3TxOrgSpecificPDULocalread-onlycurrentNID Series card Port3 Detailed Link OAM Statistics: Tx Org Specific PDU's
1.3.6.1.4.1.4756.20.500.20.1.508ColumnnidPort3TxUnsupportedCodesLocalread-onlycurrentNID Series card Port3 Detailed Link OAM Statistics: Tx Unsupported Codes
1.3.6.1.4.1.4756.20.500.20.1.509ColumnnidPort3TxLinkFaultPDULocalread-onlycurrentNID Series card Port3 Detailed Link OAM Statistics: Tx Link Fault PDU's
1.3.6.1.4.1.4756.20.500.20.1.510ColumnnidPort3TxDyingGaspLocalread-onlycurrentNID Series card Port3 Detailed Link OAM Statistics: Tx Dying Gasp
1.3.6.1.4.1.4756.20.500.20.1.511ColumnnidPort3TxCriticalEventPDULocalread-onlycurrentNID Series card Port3 Detailed Link OAM Statistics: Tx Dying Gasp
1.3.6.1.4.1.4756.20.500.20.1.512ColumnnidPort4RxOAMInfoPDULocalread-onlycurrentNID Series card Port4 Detailed Link OAM Statistics: Rx OAM Information PDU's
1.3.6.1.4.1.4756.20.500.20.1.513ColumnnidPort4RxUniqueErrorEventLocalread-onlycurrentNID Series card Port4 Detailed Link OAM Statistics: Rx Unique Error Event Notificatio
1.3.6.1.4.1.4756.20.500.20.1.514ColumnnidPort4RxDuplicateErrorEventLocalread-onlycurrentNID Series card Port4 Detailed Link OAM Statistics: Rx Duplicate Error Event Notification
1.3.6.1.4.1.4756.20.500.20.1.515ColumnnidPort4RxLoopBackControlLocalread-onlycurrentNID Series card Port4 Detailed Link OAM Statistics: Rx Loopback Control
1.3.6.1.4.1.4756.20.500.20.1.516ColumnnidPort4RxVariableRequestLocalread-onlycurrentNID Series card Port4 Detailed Link OAM Statistics: Rx Variable Request
1.3.6.1.4.1.4756.20.500.20.1.517ColumnnidPort4RxVariableResponseLocalread-onlycurrentNID Series card Port4 Detailed Link OAM Statistics: Rx Variable Response
1.3.6.1.4.1.4756.20.500.20.1.518ColumnnidPort4RxOrgSpecificPDULocalread-onlycurrentNID Series card Port4 Detailed Link OAM Statistics: Rx Org Specific PDU's
1.3.6.1.4.1.4756.20.500.20.1.519ColumnnidPort4RxUnsupportedCodesLocalread-onlycurrentNID Series card Port4 Detailed Link OAM Statistics: Rx Unsupported Codes
1.3.6.1.4.1.4756.20.500.20.1.520ColumnnidPort4RxLinkFaultPDULocalread-onlycurrentNID Series card Port4 Detailed Link OAM Statistics: Rx Link Fault PDU's
1.3.6.1.4.1.4756.20.500.20.1.521ColumnnidPort4RxDyingGaspLocalread-onlycurrentNID Series card Port4 Detailed Link OAM Statistics: Rx Dying Gasp
1.3.6.1.4.1.4756.20.500.20.1.522ColumnnidPort4RxCriticalEventPDULocalread-onlycurrentNID Series card Port4 Detailed Link OAM Statistics: Rx Dying Gasp
1.3.6.1.4.1.4756.20.500.20.1.523ColumnnidPort4TxOAMInfoPDULocalread-onlycurrentNID Series card Port4 Detailed Link OAM Statistics: Tx OAM Information PDU's
1.3.6.1.4.1.4756.20.500.20.1.524ColumnnidPort4TxUniqueErrorEventLocalread-onlycurrentNID Series card Port4 Detailed Link OAM Statistics: Tx Unique Error Event Notificatio
1.3.6.1.4.1.4756.20.500.20.1.525ColumnnidPort4TxDuplicateErrorEventLocalread-onlycurrentNID Series card Port4 Detailed Link OAM Statistics: Tx Duplicate Error Event Notification
1.3.6.1.4.1.4756.20.500.20.1.526ColumnnidPort4TxLoopBackControlLocalread-onlycurrentNID Series card Port4 Detailed Link OAM Statistics: Tx Loopback Control
1.3.6.1.4.1.4756.20.500.20.1.527ColumnnidPort4TxVariableRequestLocalread-onlycurrentNID Series card Port4 Detailed Link OAM Statistics: Tx Variable Request
1.3.6.1.4.1.4756.20.500.20.1.528ColumnnidPort4TxVariableResponseLocalread-onlycurrentNID Series card Port4 Detailed Link OAM Statistics: Tx Variable Response
1.3.6.1.4.1.4756.20.500.20.1.529ColumnnidPort4TxOrgSpecificPDULocalread-onlycurrentNID Series card Port4 Detailed Link OAM Statistics: Tx Org Specific PDU's
1.3.6.1.4.1.4756.20.500.20.1.530ColumnnidPort4TxUnsupportedCodesLocalread-onlycurrentNID Series card Port4 Detailed Link OAM Statistics: Tx Unsupported Codes
1.3.6.1.4.1.4756.20.500.20.1.531ColumnnidPort4TxLinkFaultPDULocalread-onlycurrentNID Series card Port4 Detailed Link OAM Statistics: Tx Link Fault PDU's
1.3.6.1.4.1.4756.20.500.20.1.532ColumnnidPort4TxDyingGaspLocalread-onlycurrentNID Series card Port4 Detailed Link OAM Statistics: Tx Dying Gasp
1.3.6.1.4.1.4756.20.500.20.1.533ColumnnidPort4TxCriticalEventPDULocalread-onlycurrentNID Series card Port4 Detailed Link OAM Statistics: Tx Dying Gasp
1.3.6.1.4.1.4756.20.500.20.1.534ColumnnidPort5RxOAMInfoPDULocalread-onlycurrentNID Series card Port5 Detailed Link OAM Statistics: Rx OAM Information PDU's
1.3.6.1.4.1.4756.20.500.20.1.535ColumnnidPort5RxUniqueErrorEventLocalread-onlycurrentNID Series card Port5 Detailed Link OAM Statistics: Rx Unique Error Event Notificatio
1.3.6.1.4.1.4756.20.500.20.1.536ColumnnidPort5RxDuplicateErrorEventLocalread-onlycurrentNID Series card Port5 Detailed Link OAM Statistics: Rx Duplicate Error Event Notification
1.3.6.1.4.1.4756.20.500.20.1.537ColumnnidPort5RxLoopBackControlLocalread-onlycurrentNID Series card Port5 Detailed Link OAM Statistics: Rx Loopback Control
1.3.6.1.4.1.4756.20.500.20.1.538ColumnnidPort5RxVariableRequestLocalread-onlycurrentNID Series card Port5 Detailed Link OAM Statistics: Rx Variable Request
1.3.6.1.4.1.4756.20.500.20.1.539ColumnnidPort5RxVariableResponseLocalread-onlycurrentNID Series card Port5 Detailed Link OAM Statistics: Rx Variable Response
1.3.6.1.4.1.4756.20.500.20.1.540ColumnnidPort5RxOrgSpecificPDULocalread-onlycurrentNID Series card Port5 Detailed Link OAM Statistics: Rx Org Specific PDU's
1.3.6.1.4.1.4756.20.500.20.1.541ColumnnidPort5RxUnsupportedCodesLocalread-onlycurrentNID Series card Port5 Detailed Link OAM Statistics: Rx Unsupported Codes
1.3.6.1.4.1.4756.20.500.20.1.542ColumnnidPort5RxLinkFaultPDULocalread-onlycurrentNID Series card Port5 Detailed Link OAM Statistics: Rx Link Fault PDU's
1.3.6.1.4.1.4756.20.500.20.1.543ColumnnidPort5RxDyingGaspLocalread-onlycurrentNID Series card Port5 Detailed Link OAM Statistics: Rx Dying Gasp
1.3.6.1.4.1.4756.20.500.20.1.544ColumnnidPort5RxCriticalEventPDULocalread-onlycurrentNID Series card Port5 Detailed Link OAM Statistics: Rx Dying Gasp
1.3.6.1.4.1.4756.20.500.20.1.545ColumnnidPort5TxOAMInfoPDULocalread-onlycurrentNID Series card Port5 Detailed Link OAM Statistics: Tx OAM Information PDU's
1.3.6.1.4.1.4756.20.500.20.1.546ColumnnidPort5TxUniqueErrorEventLocalread-onlycurrentNID Series card Port5 Detailed Link OAM Statistics: Tx Unique Error Event Notificatio
1.3.6.1.4.1.4756.20.500.20.1.547ColumnnidPort5TxDuplicateErrorEventLocalread-onlycurrentNID Series card Port5 Detailed Link OAM Statistics: Tx Duplicate Error Event Notification
1.3.6.1.4.1.4756.20.500.20.1.548ColumnnidPort5TxLoopBackControlLocalread-onlycurrentNID Series card Port5 Detailed Link OAM Statistics: Tx Loopback Control
1.3.6.1.4.1.4756.20.500.20.1.549ColumnnidPort5TxVariableRequestLocalread-onlycurrentNID Series card Port5 Detailed Link OAM Statistics: Tx Variable Request
1.3.6.1.4.1.4756.20.500.20.1.550ColumnnidPort5TxVariableResponseLocalread-onlycurrentNID Series card Port5 Detailed Link OAM Statistics: Tx Variable Response
1.3.6.1.4.1.4756.20.500.20.1.551ColumnnidPort5TxOrgSpecificPDULocalread-onlycurrentNID Series card Port5 Detailed Link OAM Statistics: Tx Org Specific PDU's
1.3.6.1.4.1.4756.20.500.20.1.552ColumnnidPort5TxUnsupportedCodesLocalread-onlycurrentNID Series card Port5 Detailed Link OAM Statistics: Tx Unsupported Codes
1.3.6.1.4.1.4756.20.500.20.1.553ColumnnidPort5TxLinkFaultPDULocalread-onlycurrentNID Series card Port5 Detailed Link OAM Statistics: Tx Link Fault PDU's
1.3.6.1.4.1.4756.20.500.20.1.554ColumnnidPort5TxDyingGaspLocalread-onlycurrentNID Series card Port5 Detailed Link OAM Statistics: Tx Dying Gasp
1.3.6.1.4.1.4756.20.500.20.1.555ColumnnidPort5TxCriticalEventPDULocalread-onlycurrentNID Series card Port5 Detailed Link OAM Statistics: Tx Dying Gasp
1.3.6.1.4.1.4756.20.500.20.1.556ColumnnidPort6RxOAMInfoPDULocalread-onlycurrentNID Series card Port6 Detailed Link OAM Statistics: Rx OAM Information PDU's
1.3.6.1.4.1.4756.20.500.20.1.557ColumnnidPort6RxUniqueErrorEventLocalread-onlycurrentNID Series card Port6 Detailed Link OAM Statistics: Rx Unique Error Event Notificatio
1.3.6.1.4.1.4756.20.500.20.1.558ColumnnidPort6RxDuplicateErrorEventLocalread-onlycurrentNID Series card Port6 Detailed Link OAM Statistics: Rx Duplicate Error Event Notification
1.3.6.1.4.1.4756.20.500.20.1.559ColumnnidPort6RxLoopBackControlLocalread-onlycurrentNID Series card Port6 Detailed Link OAM Statistics: Rx Loopback Control
1.3.6.1.4.1.4756.20.500.20.1.560ColumnnidPort6RxVariableRequestLocalread-onlycurrentNID Series card Port6 Detailed Link OAM Statistics: Rx Variable Request
1.3.6.1.4.1.4756.20.500.20.1.561ColumnnidPort6RxVariableResponseLocalread-onlycurrentNID Series card Port6 Detailed Link OAM Statistics: Rx Variable Response
1.3.6.1.4.1.4756.20.500.20.1.562ColumnnidPort6RxOrgSpecificPDULocalread-onlycurrentNID Series card Port6 Detailed Link OAM Statistics: Rx Org Specific PDU's
1.3.6.1.4.1.4756.20.500.20.1.563ColumnnidPort6RxUnsupportedCodesLocalread-onlycurrentNID Series card Port6 Detailed Link OAM Statistics: Rx Unsupported Codes
1.3.6.1.4.1.4756.20.500.20.1.564ColumnnidPort6RxLinkFaultPDULocalread-onlycurrentNID Series card Port6 Detailed Link OAM Statistics: Rx Link Fault PDU's
1.3.6.1.4.1.4756.20.500.20.1.565ColumnnidPort6RxDyingGaspLocalread-onlycurrentNID Series card Port6 Detailed Link OAM Statistics: Rx Dying Gasp
1.3.6.1.4.1.4756.20.500.20.1.566ColumnnidPort6RxCriticalEventPDULocalread-onlycurrentNID Series card Port6 Detailed Link OAM Statistics: Rx Dying Gasp
1.3.6.1.4.1.4756.20.500.20.1.567ColumnnidPort6TxOAMInfoPDULocalread-onlycurrentNID Series card Port6 Detailed Link OAM Statistics: Tx OAM Information PDU's
1.3.6.1.4.1.4756.20.500.20.1.568ColumnnidPort6TxUniqueErrorEventLocalread-onlycurrentNID Series card Port6 Detailed Link OAM Statistics: Tx Unique Error Event Notificatio
1.3.6.1.4.1.4756.20.500.20.1.569ColumnnidPort6TxDuplicateErrorEventLocalread-onlycurrentNID Series card Port6 Detailed Link OAM Statistics: Tx Duplicate Error Event Notification
1.3.6.1.4.1.4756.20.500.20.1.570ColumnnidPort6TxLoopBackControlLocalread-onlycurrentNID Series card Port6 Detailed Link OAM Statistics: Tx Loopback Control
1.3.6.1.4.1.4756.20.500.20.1.571ColumnnidPort6TxVariableRequestLocalread-onlycurrentNID Series card Port6 Detailed Link OAM Statistics: Tx Variable Request
1.3.6.1.4.1.4756.20.500.20.1.572ColumnnidPort6TxVariableResponseLocalread-onlycurrentNID Series card Port6 Detailed Link OAM Statistics: Tx Variable Response
1.3.6.1.4.1.4756.20.500.20.1.573ColumnnidPort6TxOrgSpecificPDULocalread-onlycurrentNID Series card Port6 Detailed Link OAM Statistics: Tx Org Specific PDU's
1.3.6.1.4.1.4756.20.500.20.1.574ColumnnidPort6TxUnsupportedCodesLocalread-onlycurrentNID Series card Port6 Detailed Link OAM Statistics: Tx Unsupported Codes
1.3.6.1.4.1.4756.20.500.20.1.575ColumnnidPort6TxLinkFaultPDULocalread-onlycurrentNID Series card Port6 Detailed Link OAM Statistics: Tx Link Fault PDU's
1.3.6.1.4.1.4756.20.500.20.1.576ColumnnidPort6TxDyingGaspLocalread-onlycurrentNID Series card Port6 Detailed Link OAM Statistics: Tx Dying Gasp
1.3.6.1.4.1.4756.20.500.20.1.577ColumnnidPort6TxCriticalEventPDULocalread-onlycurrentNID Series card Port6 Detailed Link OAM Statistics: Tx Dying Gasp
1.3.6.1.4.1.4756.20.500.20.1.578ColumnnidPort7RxOAMInfoPDULocalread-onlycurrentNID Series card Port7 Detailed Link OAM Statistics: Rx OAM Information PDU's
1.3.6.1.4.1.4756.20.500.20.1.579ColumnnidPort7RxUniqueErrorEventLocalread-onlycurrentNID Series card Port7 Detailed Link OAM Statistics: Rx Unique Error Event Notificatio
1.3.6.1.4.1.4756.20.500.20.1.580ColumnnidPort7RxDuplicateErrorEventLocalread-onlycurrentNID Series card Port7 Detailed Link OAM Statistics: Rx Duplicate Error Event Notification
1.3.6.1.4.1.4756.20.500.20.1.581ColumnnidPort7RxLoopBackControlLocalread-onlycurrentNID Series card Port7 Detailed Link OAM Statistics: Rx Loopback Control
1.3.6.1.4.1.4756.20.500.20.1.582ColumnnidPort7RxVariableRequestLocalread-onlycurrentNID Series card Port7 Detailed Link OAM Statistics: Rx Variable Request
1.3.6.1.4.1.4756.20.500.20.1.583ColumnnidPort7RxVariableResponseLocalread-onlycurrentNID Series card Port7 Detailed Link OAM Statistics: Rx Variable Response
1.3.6.1.4.1.4756.20.500.20.1.584ColumnnidPort7RxOrgSpecificPDULocalread-onlycurrentNID Series card Port7 Detailed Link OAM Statistics: Rx Org Specific PDU's
1.3.6.1.4.1.4756.20.500.20.1.585ColumnnidPort7RxUnsupportedCodesLocalread-onlycurrentNID Series card Port7 Detailed Link OAM Statistics: Rx Unsupported Codes
1.3.6.1.4.1.4756.20.500.20.1.586ColumnnidPort7RxLinkFaultPDULocalread-onlycurrentNID Series card Port7 Detailed Link OAM Statistics: Rx Link Fault PDU's
1.3.6.1.4.1.4756.20.500.20.1.587ColumnnidPort7RxDyingGaspLocalread-onlycurrentNID Series card Port7 Detailed Link OAM Statistics: Rx Dying Gasp
1.3.6.1.4.1.4756.20.500.20.1.588ColumnnidPort7RxCriticalEventPDULocalread-onlycurrentNID Series card Port7 Detailed Link OAM Statistics: Rx Dying Gasp
1.3.6.1.4.1.4756.20.500.20.1.589ColumnnidPort7TxOAMInfoPDULocalread-onlycurrentNID Series card Port7 Detailed Link OAM Statistics: Tx OAM Information PDU's
1.3.6.1.4.1.4756.20.500.20.1.590ColumnnidPort7TxUniqueErrorEventLocalread-onlycurrentNID Series card Port7 Detailed Link OAM Statistics: Tx Unique Error Event Notificatio
1.3.6.1.4.1.4756.20.500.20.1.591ColumnnidPort7TxDuplicateErrorEventLocalread-onlycurrentNID Series card Port7 Detailed Link OAM Statistics: Tx Duplicate Error Event Notification
1.3.6.1.4.1.4756.20.500.20.1.592ColumnnidPort7TxLoopBackControlLocalread-onlycurrentNID Series card Port7 Detailed Link OAM Statistics: Tx Loopback Control
1.3.6.1.4.1.4756.20.500.20.1.593ColumnnidPort7TxVariableRequestLocalread-onlycurrentNID Series card Port7 Detailed Link OAM Statistics: Tx Variable Request
1.3.6.1.4.1.4756.20.500.20.1.594ColumnnidPort7TxVariableResponseLocalread-onlycurrentNID Series card Port7 Detailed Link OAM Statistics: Tx Variable Response
1.3.6.1.4.1.4756.20.500.20.1.595ColumnnidPort7TxOrgSpecificPDULocalread-onlycurrentNID Series card Port7 Detailed Link OAM Statistics: Tx Org Specific PDU's
1.3.6.1.4.1.4756.20.500.20.1.596ColumnnidPort7TxUnsupportedCodesLocalread-onlycurrentNID Series card Port7 Detailed Link OAM Statistics: Tx Unsupported Codes
1.3.6.1.4.1.4756.20.500.20.1.597ColumnnidPort7TxLinkFaultPDULocalread-onlycurrentNID Series card Port7 Detailed Link OAM Statistics: Tx Link Fault PDU's
1.3.6.1.4.1.4756.20.500.20.1.598ColumnnidPort7TxDyingGaspLocalread-onlycurrentNID Series card Port7 Detailed Link OAM Statistics: Tx Dying Gasp
1.3.6.1.4.1.4756.20.500.20.1.599ColumnnidPort7TxCriticalEventPDULocalread-onlycurrentNID Series card Port7 Detailed Link OAM Statistics: Tx Dying Gasp
1.3.6.1.4.1.4756.20.500.20.1.600ColumnnidPort8RxOAMInfoPDULocalread-onlycurrentNID Series card Port8 Detailed Link OAM Statistics: Rx OAM Information PDU's
1.3.6.1.4.1.4756.20.500.20.1.601ColumnnidPort8RxUniqueErrorEventLocalread-onlycurrentNID Series card Port8 Detailed Link OAM Statistics: Rx Unique Error Event Notificatio
1.3.6.1.4.1.4756.20.500.20.1.602ColumnnidPort8RxDuplicateErrorEventLocalread-onlycurrentNID Series card Port8 Detailed Link OAM Statistics: Rx Duplicate Error Event Notification
1.3.6.1.4.1.4756.20.500.20.1.603ColumnnidPort8RxLoopBackControlLocalread-onlycurrentNID Series card Port8 Detailed Link OAM Statistics: Rx Loopback Control
1.3.6.1.4.1.4756.20.500.20.1.604ColumnnidPort8RxVariableRequestLocalread-onlycurrentNID Series card Port8 Detailed Link OAM Statistics: Rx Variable Request
1.3.6.1.4.1.4756.20.500.20.1.605ColumnnidPort8RxVariableResponseLocalread-onlycurrentNID Series card Port8 Detailed Link OAM Statistics: Rx Variable Response
1.3.6.1.4.1.4756.20.500.20.1.606ColumnnidPort8RxOrgSpecificPDULocalread-onlycurrentNID Series card Port8 Detailed Link OAM Statistics: Rx Org Specific PDU's
1.3.6.1.4.1.4756.20.500.20.1.607ColumnnidPort8RxUnsupportedCodesLocalread-onlycurrentNID Series card Port8 Detailed Link OAM Statistics: Rx Unsupported Codes
1.3.6.1.4.1.4756.20.500.20.1.608ColumnnidPort8RxLinkFaultPDULocalread-onlycurrentNID Series card Port8 Detailed Link OAM Statistics: Rx Link Fault PDU's
1.3.6.1.4.1.4756.20.500.20.1.609ColumnnidPort8RxDyingGaspLocalread-onlycurrentNID Series card Port8 Detailed Link OAM Statistics: Rx Dying Gasp
1.3.6.1.4.1.4756.20.500.20.1.610ColumnnidPort8RxCriticalEventPDULocalread-onlycurrentNID Series card Port8 Detailed Link OAM Statistics: Rx Dying Gasp
1.3.6.1.4.1.4756.20.500.20.1.611ColumnnidPort8TxOAMInfoPDULocalread-onlycurrentNID Series card Port8 Detailed Link OAM Statistics: Tx OAM Information PDU's
1.3.6.1.4.1.4756.20.500.20.1.612ColumnnidPort8TxUniqueErrorEventLocalread-onlycurrentNID Series card Port8 Detailed Link OAM Statistics: Tx Unique Error Event Notificatio
1.3.6.1.4.1.4756.20.500.20.1.613ColumnnidPort8TxDuplicateErrorEventLocalread-onlycurrentNID Series card Port8 Detailed Link OAM Statistics: Tx Duplicate Error Event Notification
1.3.6.1.4.1.4756.20.500.20.1.614ColumnnidPort8TxLoopBackControlLocalread-onlycurrentNID Series card Port8 Detailed Link OAM Statistics: Tx Loopback Control
1.3.6.1.4.1.4756.20.500.20.1.615ColumnnidPort8TxVariableRequestLocalread-onlycurrentNID Series card Port8 Detailed Link OAM Statistics: Tx Variable Request
1.3.6.1.4.1.4756.20.500.20.1.616ColumnnidPort8TxVariableResponseLocalread-onlycurrentNID Series card Port8 Detailed Link OAM Statistics: Tx Variable Response
1.3.6.1.4.1.4756.20.500.20.1.617ColumnnidPort8TxOrgSpecificPDULocalread-onlycurrentNID Series card Port8 Detailed Link OAM Statistics: Tx Org Specific PDU's
1.3.6.1.4.1.4756.20.500.20.1.618ColumnnidPort8TxUnsupportedCodesLocalread-onlycurrentNID Series card Port8 Detailed Link OAM Statistics: Tx Unsupported Codes
1.3.6.1.4.1.4756.20.500.20.1.619ColumnnidPort8TxLinkFaultPDULocalread-onlycurrentNID Series card Port8 Detailed Link OAM Statistics: Tx Link Fault PDU's
1.3.6.1.4.1.4756.20.500.20.1.620ColumnnidPort8TxDyingGaspLocalread-onlycurrentNID Series card Port8 Detailed Link OAM Statistics: Tx Dying Gasp
1.3.6.1.4.1.4756.20.500.20.1.621ColumnnidPort8TxCriticalEventPDULocalread-onlycurrentNID Series card Port8 Detailed Link OAM Statistics: Tx Dying Gasp
1.3.6.1.4.1.4756.20.500.20.1.622ColumnnidPort1PDUPermisionLocalread-onlycurrentNID Series card Detailed Link OAM Status for Port 1: PDU Permission
1.3.6.1.4.1.4756.20.500.20.1.623ColumnnidPort1DiscoveryStateLocalread-onlycurrentNID Series card Detailed Link OAM Status for Port 1: Discovery State
1.3.6.1.4.1.4756.20.500.20.1.624ColumnnidPort1PeerMACAddrLocalread-onlycurrentNID Series card Detailed Link OAM Status for Port 1: Discovery State
1.3.6.1.4.1.4756.20.500.20.1.625ColumnnidPort1LocalModeLocalread-onlycurrentNID Series card Detailed Link OAM Status for Port 1: Local: Mode
1.3.6.1.4.1.4756.20.500.20.1.626ColumnnidPort1LocalUnOperationLocalread-onlycurrentNID Series card Detailed Link OAM Status for Port 1: Local: Unidirectional Operation Support
1.3.6.1.4.1.4756.20.500.20.1.627ColumnnidPort1LocalRemoteLbLocalread-onlycurrentNID Series card Detailed Link OAM Status for Port 1: Local: Remote Loopback Support
1.3.6.1.4.1.4756.20.500.20.1.628ColumnnidPort1LocalLMLocalread-onlycurrentNID Series card Detailed Link OAM Status for Port 1: Local: Link Monitoring Support
1.3.6.1.4.1.4756.20.500.20.1.629ColumnnidPort1LocalMIBRetrievalLocalread-onlycurrentNID Series card Detailed Link OAM Status for Port 1: Local: MIB Retrieval Support
1.3.6.1.4.1.4756.20.500.20.1.630ColumnnidPort1LocalMTUSizeLocalread-onlycurrentNID Series card Detailed Link OAM Status for Port 1: Local: MTU Size
1.3.6.1.4.1.4756.20.500.20.1.631ColumnnidPort1LocalMultiStateLocalread-onlycurrentNID Series card Detailed Link OAM Status for Port 1: Local: Multiplexer State
1.3.6.1.4.1.4756.20.500.20.1.632ColumnnidPort1LocalParserStateLocalread-onlycurrentNID Series card Detailed Link OAM Status for Port 1: Local: Multiplexer State
1.3.6.1.4.1.4756.20.500.20.1.633ColumnnidPort1LocalOUILocalread-onlycurrentNID Series card Detailed Link OAM Status for Port 1: Local: Organizational Unique Identification
1.3.6.1.4.1.4756.20.500.20.1.634ColumnnidPort1LocalPDURevLocalread-onlycurrentNID Series card Detailed Link OAM Status for Port 1: Local: PDU Revision
1.3.6.1.4.1.4756.20.500.20.1.635ColumnnidPort1PeerModeLocalread-onlycurrentNID Series card Detailed Link OAM Status for Port 1: Peer: Mode
1.3.6.1.4.1.4756.20.500.20.1.636ColumnnidPort1PeerUnOperationLocalread-onlycurrentNID Series card Detailed Link OAM Status for Port 1: Peer: Unidirectional Operation Support
1.3.6.1.4.1.4756.20.500.20.1.637ColumnnidPort1PeerRemoteLbLocalread-onlycurrentNID Series card Detailed Link OAM Status for Port 1: Peer: Remote Loopback Support
1.3.6.1.4.1.4756.20.500.20.1.638ColumnnidPort1PeerLMLocalread-onlycurrentNID Series card Detailed Link OAM Status for Port 1: Peer: Link Monitoring Support
1.3.6.1.4.1.4756.20.500.20.1.639ColumnnidPort1PeerMIBRetrievalLocalread-onlycurrentNID Series card Detailed Link OAM Status for Port 1: Peer: MIB Retrieval Support
1.3.6.1.4.1.4756.20.500.20.1.640ColumnnidPort1PeerMTUSizeLocalread-onlycurrentNID Series card Detailed Link OAM Status for Port 1: Peer: MTU Size
1.3.6.1.4.1.4756.20.500.20.1.641ColumnnidPort1PeerMultiStateLocalread-onlycurrentNID Series card Detailed Link OAM Status for Port 1: Peer: Multiplexer State
1.3.6.1.4.1.4756.20.500.20.1.642ColumnnidPort1PeerParserStateLocalread-onlycurrentNID Series card Detailed Link OAM Status for Port 1: Peer: Multiplexer State
1.3.6.1.4.1.4756.20.500.20.1.643ColumnnidPort1PeerOUILocalread-onlycurrentNID Series card Detailed Link OAM Status for Port 1: Peer: Organizational Unique Identification
1.3.6.1.4.1.4756.20.500.20.1.644ColumnnidPort1PeerPDURevLocalread-onlycurrentNID Series card Detailed Link OAM Status for Port 1: Peer: PDU Revision
1.3.6.1.4.1.4756.20.500.20.1.645ColumnnidPort2PDUPermisionLocalread-onlycurrentNID Series card Detailed Link OAM Status for Port 2: PDU Permission
1.3.6.1.4.1.4756.20.500.20.1.646ColumnnidPort2DiscoveryStateLocalread-onlycurrentNID Series card Detailed Link OAM Status for Port 2: Discovery State
1.3.6.1.4.1.4756.20.500.20.1.647ColumnnidPort2PeerMACAddrLocalread-onlycurrentNID Series card Detailed Link OAM Status for Port 2: Discovery State
1.3.6.1.4.1.4756.20.500.20.1.648ColumnnidPort2LocalModeLocalread-onlycurrentNID Series card Detailed Link OAM Status for Port 2: Local: Mode
1.3.6.1.4.1.4756.20.500.20.1.649ColumnnidPort2LocalUnOperationLocalread-onlycurrentNID Series card Detailed Link OAM Status for Port 2: Local: Unidirectional Operation Support
1.3.6.1.4.1.4756.20.500.20.1.650ColumnnidPort2LocalRemoteLbLocalread-onlycurrentNID Series card Detailed Link OAM Status for Port 2: Local: Remote Loopback Support
1.3.6.1.4.1.4756.20.500.20.1.651ColumnnidPort2LocalLMLocalread-onlycurrentNID Series card Detailed Link OAM Status for Port 2: Local: Link Monitoring Support
1.3.6.1.4.1.4756.20.500.20.1.652ColumnnidPort2LocalMIBRetrievalLocalread-onlycurrentNID Series card Detailed Link OAM Status for Port 2: Local: MIB Retrieval Support
1.3.6.1.4.1.4756.20.500.20.1.653ColumnnidPort2LocalMTUSizeLocalread-onlycurrentNID Series card Detailed Link OAM Status for Port 2: Local: MTU Size
1.3.6.1.4.1.4756.20.500.20.1.654ColumnnidPort2LocalMultiStateLocalread-onlycurrentNID Series card Detailed Link OAM Status for Port 2: Local: Multiplexer State
1.3.6.1.4.1.4756.20.500.20.1.655ColumnnidPort2LocalParserStateLocalread-onlycurrentNID Series card Detailed Link OAM Status for Port 2: Local: Multiplexer State
1.3.6.1.4.1.4756.20.500.20.1.656ColumnnidPort2LocalOUILocalread-onlycurrentNID Series card Detailed Link OAM Status for Port 2: Local: Organizational Unique Identification
1.3.6.1.4.1.4756.20.500.20.1.657ColumnnidPort2LocalPDURevLocalread-onlycurrentNID Series card Detailed Link OAM Status for Port 2: Local: PDU Revision
1.3.6.1.4.1.4756.20.500.20.1.658ColumnnidPort2PeerModeLocalread-onlycurrentNID Series card Detailed Link OAM Status for Port 2: Peer: Mode
1.3.6.1.4.1.4756.20.500.20.1.659ColumnnidPort2PeerUnOperationLocalread-onlycurrentNID Series card Detailed Link OAM Status for Port 2: Peer: Unidirectional Operation Support
1.3.6.1.4.1.4756.20.500.20.1.660ColumnnidPort2PeerRemoteLbLocalread-onlycurrentNID Series card Detailed Link OAM Status for Port 2: Peer: Remote Loopback Support
1.3.6.1.4.1.4756.20.500.20.1.661ColumnnidPort2PeerLMLocalread-onlycurrentNID Series card Detailed Link OAM Status for Port 2: Peer: Link Monitoring Support
1.3.6.1.4.1.4756.20.500.20.1.662ColumnnidPort2PeerMIBRetrievalLocalread-onlycurrentNID Series card Detailed Link OAM Status for Port 2: Peer: MIB Retrieval Support
1.3.6.1.4.1.4756.20.500.20.1.663ColumnnidPort2PeerMTUSizeLocalread-onlycurrentNID Series card Detailed Link OAM Status for Port 2: Peer: MTU Size
1.3.6.1.4.1.4756.20.500.20.1.664ColumnnidPort2PeerMultiStateLocalread-onlycurrentNID Series card Detailed Link OAM Status for Port 2: Peer: Multiplexer State
1.3.6.1.4.1.4756.20.500.20.1.665ColumnnidPort2PeerParserStateLocalread-onlycurrentNID Series card Detailed Link OAM Status for Port 2: Peer: Multiplexer State
1.3.6.1.4.1.4756.20.500.20.1.666ColumnnidPort2PeerOUILocalread-onlycurrentNID Series card Detailed Link OAM Status for Port 2: Peer: Organizational Unique Identification
1.3.6.1.4.1.4756.20.500.20.1.667ColumnnidPort2PeerPDURevLocalread-onlycurrentNID Series card Detailed Link OAM Status for Port 2: Peer: PDU Revision
1.3.6.1.4.1.4756.20.500.20.1.668ColumnnidPort3PDUPermisionLocalread-onlycurrentNID Series card Detailed Link OAM Status for Port 3: PDU Permission
1.3.6.1.4.1.4756.20.500.20.1.669ColumnnidPort3DiscoveryStateLocalread-onlycurrentNID Series card Detailed Link OAM Status for Port 3: Discovery State
1.3.6.1.4.1.4756.20.500.20.1.670ColumnnidPort3PeerMACAddrLocalread-onlycurrentNID Series card Detailed Link OAM Status for Port 3: Discovery State
1.3.6.1.4.1.4756.20.500.20.1.671ColumnnidPort3LocalModeLocalread-onlycurrentNID Series card Detailed Link OAM Status for Port 3: Local: Mode
1.3.6.1.4.1.4756.20.500.20.1.672ColumnnidPort3LocalUnOperationLocalread-onlycurrentNID Series card Detailed Link OAM Status for Port 3: Local: Unidirectional Operation Support
1.3.6.1.4.1.4756.20.500.20.1.673ColumnnidPort3LocalRemoteLbLocalread-onlycurrentNID Series card Detailed Link OAM Status for Port 3: Local: Remote Loopback Support
1.3.6.1.4.1.4756.20.500.20.1.674ColumnnidPort3LocalLMLocalread-onlycurrentNID Series card Detailed Link OAM Status for Port 3: Local: Link Monitoring Support
1.3.6.1.4.1.4756.20.500.20.1.675ColumnnidPort3LocalMIBRetrievalLocalread-onlycurrentNID Series card Detailed Link OAM Status for Port 3: Local: MIB Retrieval Support
1.3.6.1.4.1.4756.20.500.20.1.676ColumnnidPort3LocalMTUSizeLocalread-onlycurrentNID Series card Detailed Link OAM Status for Port 3: Local: MTU Size
1.3.6.1.4.1.4756.20.500.20.1.677ColumnnidPort3LocalMultiStateLocalread-onlycurrentNID Series card Detailed Link OAM Status for Port 3: Local: Multiplexer State
1.3.6.1.4.1.4756.20.500.20.1.678ColumnnidPort3LocalParserStateLocalread-onlycurrentNID Series card Detailed Link OAM Status for Port 3: Local: Multiplexer State
1.3.6.1.4.1.4756.20.500.20.1.679ColumnnidPort3LocalOUILocalread-onlycurrentNID Series card Detailed Link OAM Status for Port 3: Local: Organizational Unique Identification
1.3.6.1.4.1.4756.20.500.20.1.680ColumnnidPort3LocalPDURevLocalread-onlycurrentNID Series card Detailed Link OAM Status for Port 3: Local: PDU Revision
1.3.6.1.4.1.4756.20.500.20.1.681ColumnnidPort3PeerModeLocalread-onlycurrentNID Series card Detailed Link OAM Status for Port 3: Peer: Mode
1.3.6.1.4.1.4756.20.500.20.1.682ColumnnidPort3PeerUnOperationLocalread-onlycurrentNID Series card Detailed Link OAM Status for Port 3: Peer: Unidirectional Operation Support
1.3.6.1.4.1.4756.20.500.20.1.683ColumnnidPort3PeerRemoteLbLocalread-onlycurrentNID Series card Detailed Link OAM Status for Port 3: Peer: Remote Loopback Support
1.3.6.1.4.1.4756.20.500.20.1.684ColumnnidPort3PeerLMLocalread-onlycurrentNID Series card Detailed Link OAM Status for Port 3: Peer: Link Monitoring Support
1.3.6.1.4.1.4756.20.500.20.1.685ColumnnidPort3PeerMIBRetrievalLocalread-onlycurrentNID Series card Detailed Link OAM Status for Port 3: Peer: MIB Retrieval Support
1.3.6.1.4.1.4756.20.500.20.1.686ColumnnidPort3PeerMTUSizeLocalread-onlycurrentNID Series card Detailed Link OAM Status for Port 3: Peer: MTU Size
1.3.6.1.4.1.4756.20.500.20.1.687ColumnnidPort3PeerMultiStateLocalread-onlycurrentNID Series card Detailed Link OAM Status for Port 3: Peer: Multiplexer State
1.3.6.1.4.1.4756.20.500.20.1.688ColumnnidPort3PeerParserStateLocalread-onlycurrentNID Series card Detailed Link OAM Status for Port 3: Peer: Multiplexer State
1.3.6.1.4.1.4756.20.500.20.1.689ColumnnidPort3PeerOUILocalread-onlycurrentNID Series card Detailed Link OAM Status for Port 3: Peer: Organizational Unique Identification
1.3.6.1.4.1.4756.20.500.20.1.690ColumnnidPort3PeerPDURevLocalread-onlycurrentNID Series card Detailed Link OAM Status for Port 3: Peer: PDU Revision
1.3.6.1.4.1.4756.20.500.20.1.691ColumnnidPort4PDUPermisionLocalread-onlycurrentNID Series card Detailed Link OAM Status for Port 4: PDU Permission
1.3.6.1.4.1.4756.20.500.20.1.692ColumnnidPort4DiscoveryStateLocalread-onlycurrentNID Series card Detailed Link OAM Status for Port 4: Discovery State
1.3.6.1.4.1.4756.20.500.20.1.693ColumnnidPort4PeerMACAddrLocalread-onlycurrentNID Series card Detailed Link OAM Status for Port 4: Discovery State
1.3.6.1.4.1.4756.20.500.20.1.694ColumnnidPort4LocalModeLocalread-onlycurrentNID Series card Detailed Link OAM Status for Port 4: Local: Mode
1.3.6.1.4.1.4756.20.500.20.1.695ColumnnidPort4LocalUnOperationLocalread-onlycurrentNID Series card Detailed Link OAM Status for Port 4: Local: Unidirectional Operation Support
1.3.6.1.4.1.4756.20.500.20.1.696ColumnnidPort4LocalRemoteLbLocalread-onlycurrentNID Series card Detailed Link OAM Status for Port 4: Local: Remote Loopback Support
1.3.6.1.4.1.4756.20.500.20.1.697ColumnnidPort4LocalLMLocalread-onlycurrentNID Series card Detailed Link OAM Status for Port 4: Local: Link Monitoring Support
1.3.6.1.4.1.4756.20.500.20.1.698ColumnnidPort4LocalMIBRetrievalLocalread-onlycurrentNID Series card Detailed Link OAM Status for Port 4: Local: MIB Retrieval Support
1.3.6.1.4.1.4756.20.500.20.1.699ColumnnidPort4LocalMTUSizeLocalread-onlycurrentNID Series card Detailed Link OAM Status for Port 4: Local: MTU Size
1.3.6.1.4.1.4756.20.500.20.1.700ColumnnidPort4LocalMultiStateLocalread-onlycurrentNID Series card Detailed Link OAM Status for Port 4: Local: Multiplexer State
1.3.6.1.4.1.4756.20.500.20.1.701ColumnnidPort4LocalParserStateLocalread-onlycurrentNID Series card Detailed Link OAM Status for Port 4: Local: Multiplexer State
1.3.6.1.4.1.4756.20.500.20.1.702ColumnnidPort4LocalOUILocalread-onlycurrentNID Series card Detailed Link OAM Status for Port 4: Local: Organizational Unique Identification
1.3.6.1.4.1.4756.20.500.20.1.703ColumnnidPort4LocalPDURevLocalread-onlycurrentNID Series card Detailed Link OAM Status for Port 4: Local: PDU Revision
1.3.6.1.4.1.4756.20.500.20.1.704ColumnnidPort4PeerModeLocalread-onlycurrentNID Series card Detailed Link OAM Status for Port 4: Peer: Mode
1.3.6.1.4.1.4756.20.500.20.1.705ColumnnidPort4PeerUnOperationLocalread-onlycurrentNID Series card Detailed Link OAM Status for Port 4: Peer: Unidirectional Operation Support
1.3.6.1.4.1.4756.20.500.20.1.706ColumnnidPort4PeerRemoteLbLocalread-onlycurrentNID Series card Detailed Link OAM Status for Port 4: Peer: Remote Loopback Support
1.3.6.1.4.1.4756.20.500.20.1.707ColumnnidPort4PeerLMLocalread-onlycurrentNID Series card Detailed Link OAM Status for Port 4: Peer: Link Monitoring Support
1.3.6.1.4.1.4756.20.500.20.1.708ColumnnidPort4PeerMIBRetrievalLocalread-onlycurrentNID Series card Detailed Link OAM Status for Port 4: Peer: MIB Retrieval Support
1.3.6.1.4.1.4756.20.500.20.1.709ColumnnidPort4PeerMTUSizeLocalread-onlycurrentNID Series card Detailed Link OAM Status for Port 4: Peer: MTU Size
1.3.6.1.4.1.4756.20.500.20.1.710ColumnnidPort4PeerMultiStateLocalread-onlycurrentNID Series card Detailed Link OAM Status for Port 4: Peer: Multiplexer State
1.3.6.1.4.1.4756.20.500.20.1.711ColumnnidPort4PeerParserStateLocalread-onlycurrentNID Series card Detailed Link OAM Status for Port 4: Peer: Multiplexer State
1.3.6.1.4.1.4756.20.500.20.1.712ColumnnidPort4PeerOUILocalread-onlycurrentNID Series card Detailed Link OAM Status for Port 4: Peer: Organizational Unique Identification
1.3.6.1.4.1.4756.20.500.20.1.713ColumnnidPort4PeerPDURevLocalread-onlycurrentNID Series card Detailed Link OAM Status for Port 4: Peer: PDU Revision
1.3.6.1.4.1.4756.20.500.20.1.714ColumnnidPort5PDUPermisionLocalread-onlycurrentNID Series card Detailed Link OAM Status for Port 5: PDU Permission
1.3.6.1.4.1.4756.20.500.20.1.715ColumnnidPort5DiscoveryStateLocalread-onlycurrentNID Series card Detailed Link OAM Status for Port 5: Discovery State
1.3.6.1.4.1.4756.20.500.20.1.716ColumnnidPort5PeerMACAddrLocalread-onlycurrentNID Series card Detailed Link OAM Status for Port 5: Discovery State
1.3.6.1.4.1.4756.20.500.20.1.717ColumnnidPort5LocalModeLocalread-onlycurrentNID Series card Detailed Link OAM Status for Port 5: Local: Mode
1.3.6.1.4.1.4756.20.500.20.1.718ColumnnidPort5LocalUnOperationLocalread-onlycurrentNID Series card Detailed Link OAM Status for Port 5: Local: Unidirectional Operation Support
1.3.6.1.4.1.4756.20.500.20.1.719ColumnnidPort5LocalRemoteLbLocalread-onlycurrentNID Series card Detailed Link OAM Status for Port 5: Local: Remote Loopback Support
1.3.6.1.4.1.4756.20.500.20.1.720ColumnnidPort5LocalLMLocalread-onlycurrentNID Series card Detailed Link OAM Status for Port 5: Local: Link Monitoring Support
1.3.6.1.4.1.4756.20.500.20.1.721ColumnnidPort5LocalMIBRetrievalLocalread-onlycurrentNID Series card Detailed Link OAM Status for Port 5: Local: MIB Retrieval Support
1.3.6.1.4.1.4756.20.500.20.1.722ColumnnidPort5LocalMTUSizeLocalread-onlycurrentNID Series card Detailed Link OAM Status for Port 5: Local: MTU Size
1.3.6.1.4.1.4756.20.500.20.1.723ColumnnidPort5LocalMultiStateLocalread-onlycurrentNID Series card Detailed Link OAM Status for Port 5: Local: Multiplexer State
1.3.6.1.4.1.4756.20.500.20.1.724ColumnnidPort5LocalParserStateLocalread-onlycurrentNID Series card Detailed Link OAM Status for Port 5: Local: Multiplexer State
1.3.6.1.4.1.4756.20.500.20.1.725ColumnnidPort5LocalOUILocalread-onlycurrentNID Series card Detailed Link OAM Status for Port 5: Local: Organizational Unique Identification
1.3.6.1.4.1.4756.20.500.20.1.726ColumnnidPort5LocalPDURevLocalread-onlycurrentNID Series card Detailed Link OAM Status for Port 5: Local: PDU Revision
1.3.6.1.4.1.4756.20.500.20.1.727ColumnnidPort5PeerModeLocalread-onlycurrentNID Series card Detailed Link OAM Status for Port 5: Peer: Mode
1.3.6.1.4.1.4756.20.500.20.1.728ColumnnidPort5PeerUnOperationLocalread-onlycurrentNID Series card Detailed Link OAM Status for Port 5: Peer: Unidirectional Operation Support
1.3.6.1.4.1.4756.20.500.20.1.729ColumnnidPort5PeerRemoteLbLocalread-onlycurrentNID Series card Detailed Link OAM Status for Port 5: Peer: Remote Loopback Support
1.3.6.1.4.1.4756.20.500.20.1.730ColumnnidPort5PeerLMLocalread-onlycurrentNID Series card Detailed Link OAM Status for Port 5: Peer: Link Monitoring Support
1.3.6.1.4.1.4756.20.500.20.1.731ColumnnidPort5PeerMIBRetrievalLocalread-onlycurrentNID Series card Detailed Link OAM Status for Port 5: Peer: MIB Retrieval Support
1.3.6.1.4.1.4756.20.500.20.1.732ColumnnidPort5PeerMTUSizeLocalread-onlycurrentNID Series card Detailed Link OAM Status for Port 5: Peer: MTU Size
1.3.6.1.4.1.4756.20.500.20.1.733ColumnnidPort5PeerMultiStateLocalread-onlycurrentNID Series card Detailed Link OAM Status for Port 5: Peer: Multiplexer State
1.3.6.1.4.1.4756.20.500.20.1.734ColumnnidPort5PeerParserStateLocalread-onlycurrentNID Series card Detailed Link OAM Status for Port 5: Peer: Multiplexer State
1.3.6.1.4.1.4756.20.500.20.1.735ColumnnidPort5PeerOUILocalread-onlycurrentNID Series card Detailed Link OAM Status for Port 5: Peer: Organizational Unique Identification
1.3.6.1.4.1.4756.20.500.20.1.736ColumnnidPort5PeerPDURevLocalread-onlycurrentNID Series card Detailed Link OAM Status for Port 5: Peer: PDU Revision
1.3.6.1.4.1.4756.20.500.20.1.737ColumnnidPort6PDUPermisionLocalread-onlycurrentNID Series card Detailed Link OAM Status for Port 6: PDU Permission
1.3.6.1.4.1.4756.20.500.20.1.738ColumnnidPort6DiscoveryStateLocalread-onlycurrentNID Series card Detailed Link OAM Status for Port 6: Discovery State
1.3.6.1.4.1.4756.20.500.20.1.739ColumnnidPort6PeerMACAddrLocalread-onlycurrentNID Series card Detailed Link OAM Status for Port 6: Discovery State
1.3.6.1.4.1.4756.20.500.20.1.740ColumnnidPort6LocalModeLocalread-onlycurrentNID Series card Detailed Link OAM Status for Port 6: Local: Mode
1.3.6.1.4.1.4756.20.500.20.1.741ColumnnidPort6LocalUnOperationLocalread-onlycurrentNID Series card Detailed Link OAM Status for Port 6: Local: Unidirectional Operation Support
1.3.6.1.4.1.4756.20.500.20.1.742ColumnnidPort6LocalRemoteLbLocalread-onlycurrentNID Series card Detailed Link OAM Status for Port 6: Local: Remote Loopback Support
1.3.6.1.4.1.4756.20.500.20.1.743ColumnnidPort6LocalLMLocalread-onlycurrentNID Series card Detailed Link OAM Status for Port 6: Local: Link Monitoring Support
1.3.6.1.4.1.4756.20.500.20.1.744ColumnnidPort6LocalMIBRetrievalLocalread-onlycurrentNID Series card Detailed Link OAM Status for Port 6: Local: MIB Retrieval Support
1.3.6.1.4.1.4756.20.500.20.1.745ColumnnidPort6LocalMTUSizeLocalread-onlycurrentNID Series card Detailed Link OAM Status for Port 6: Local: MTU Size
1.3.6.1.4.1.4756.20.500.20.1.746ColumnnidPort6LocalMultiStateLocalread-onlycurrentNID Series card Detailed Link OAM Status for Port 6: Local: Multiplexer State
1.3.6.1.4.1.4756.20.500.20.1.747ColumnnidPort6LocalParserStateLocalread-onlycurrentNID Series card Detailed Link OAM Status for Port 6: Local: Multiplexer State
1.3.6.1.4.1.4756.20.500.20.1.748ColumnnidPort6LocalOUILocalread-onlycurrentNID Series card Detailed Link OAM Status for Port 6: Local: Organizational Unique Identification
1.3.6.1.4.1.4756.20.500.20.1.749ColumnnidPort6LocalPDURevLocalread-onlycurrentNID Series card Detailed Link OAM Status for Port 6: Local: PDU Revision
1.3.6.1.4.1.4756.20.500.20.1.750ColumnnidPort6PeerModeLocalread-onlycurrentNID Series card Detailed Link OAM Status for Port 6: Peer: Mode
1.3.6.1.4.1.4756.20.500.20.1.751ColumnnidPort6PeerUnOperationLocalread-onlycurrentNID Series card Detailed Link OAM Status for Port 6: Peer: Unidirectional Operation Support
1.3.6.1.4.1.4756.20.500.20.1.752ColumnnidPort6PeerRemoteLbLocalread-onlycurrentNID Series card Detailed Link OAM Status for Port 6: Peer: Remote Loopback Support
1.3.6.1.4.1.4756.20.500.20.1.753ColumnnidPort6PeerLMLocalread-onlycurrentNID Series card Detailed Link OAM Status for Port 6: Peer: Link Monitoring Support
1.3.6.1.4.1.4756.20.500.20.1.754ColumnnidPort6PeerMIBRetrievalLocalread-onlycurrentNID Series card Detailed Link OAM Status for Port 6: Peer: MIB Retrieval Support
1.3.6.1.4.1.4756.20.500.20.1.755ColumnnidPort6PeerMTUSizeLocalread-onlycurrentNID Series card Detailed Link OAM Status for Port 6: Peer: MTU Size
1.3.6.1.4.1.4756.20.500.20.1.756ColumnnidPort6PeerMultiStateLocalread-onlycurrentNID Series card Detailed Link OAM Status for Port 6: Peer: Multiplexer State
1.3.6.1.4.1.4756.20.500.20.1.757ColumnnidPort6PeerParserStateLocalread-onlycurrentNID Series card Detailed Link OAM Status for Port 6: Peer: Multiplexer State
1.3.6.1.4.1.4756.20.500.20.1.758ColumnnidPort6PeerOUILocalread-onlycurrentNID Series card Detailed Link OAM Status for Port 6: Peer: Organizational Unique Identification
1.3.6.1.4.1.4756.20.500.20.1.759ColumnnidPort6PeerPDURevLocalread-onlycurrentNID Series card Detailed Link OAM Status for Port 6: Peer: PDU Revision
1.3.6.1.4.1.4756.20.500.20.1.760ColumnnidPort7PDUPermisionLocalread-onlycurrentNID Series card Detailed Link OAM Status for Port 7: PDU Permission
1.3.6.1.4.1.4756.20.500.20.1.761ColumnnidPort7DiscoveryStateLocalread-onlycurrentNID Series card Detailed Link OAM Status for Port 7: Discovery State
1.3.6.1.4.1.4756.20.500.20.1.762ColumnnidPort7PeerMACAddrLocalread-onlycurrentNID Series card Detailed Link OAM Status for Port 7: Discovery State
1.3.6.1.4.1.4756.20.500.20.1.763ColumnnidPort7LocalModeLocalread-onlycurrentNID Series card Detailed Link OAM Status for Port 7: Local: Mode
1.3.6.1.4.1.4756.20.500.20.1.764ColumnnidPort7LocalUnOperationLocalread-onlycurrentNID Series card Detailed Link OAM Status for Port 7: Local: Unidirectional Operation Support
1.3.6.1.4.1.4756.20.500.20.1.765ColumnnidPort7LocalRemoteLbLocalread-onlycurrentNID Series card Detailed Link OAM Status for Port 7: Local: Remote Loopback Support
1.3.6.1.4.1.4756.20.500.20.1.766ColumnnidPort7LocalLMLocalread-onlycurrentNID Series card Detailed Link OAM Status for Port 7: Local: Link Monitoring Support
1.3.6.1.4.1.4756.20.500.20.1.767ColumnnidPort7LocalMIBRetrievalLocalread-onlycurrentNID Series card Detailed Link OAM Status for Port 7: Local: MIB Retrieval Support
1.3.6.1.4.1.4756.20.500.20.1.768ColumnnidPort7LocalMTUSizeLocalread-onlycurrentNID Series card Detailed Link OAM Status for Port 7: Local: MTU Size
1.3.6.1.4.1.4756.20.500.20.1.769ColumnnidPort7LocalMultiStateLocalread-onlycurrentNID Series card Detailed Link OAM Status for Port 7: Local: Multiplexer State
1.3.6.1.4.1.4756.20.500.20.1.770ColumnnidPort7LocalParserStateLocalread-onlycurrentNID Series card Detailed Link OAM Status for Port 7: Local: Multiplexer State
1.3.6.1.4.1.4756.20.500.20.1.771ColumnnidPort7LocalOUILocalread-onlycurrentNID Series card Detailed Link OAM Status for Port 7: Local: Organizational Unique Identification
1.3.6.1.4.1.4756.20.500.20.1.772ColumnnidPort7LocalPDURevLocalread-onlycurrentNID Series card Detailed Link OAM Status for Port 7: Local: PDU Revision
1.3.6.1.4.1.4756.20.500.20.1.773ColumnnidPort7PeerModeLocalread-onlycurrentNID Series card Detailed Link OAM Status for Port 7: Peer: Mode
1.3.6.1.4.1.4756.20.500.20.1.774ColumnnidPort7PeerUnOperationLocalread-onlycurrentNID Series card Detailed Link OAM Status for Port 7: Peer: Unidirectional Operation Support
1.3.6.1.4.1.4756.20.500.20.1.775ColumnnidPort7PeerRemoteLbLocalread-onlycurrentNID Series card Detailed Link OAM Status for Port 7: Peer: Remote Loopback Support
1.3.6.1.4.1.4756.20.500.20.1.776ColumnnidPort7PeerLMLocalread-onlycurrentNID Series card Detailed Link OAM Status for Port 7: Peer: Link Monitoring Support
1.3.6.1.4.1.4756.20.500.20.1.777ColumnnidPort7PeerMIBRetrievalLocalread-onlycurrentNID Series card Detailed Link OAM Status for Port 7: Peer: MIB Retrieval Support
1.3.6.1.4.1.4756.20.500.20.1.778ColumnnidPort7PeerMTUSizeLocalread-onlycurrentNID Series card Detailed Link OAM Status for Port 7: Peer: MTU Size
1.3.6.1.4.1.4756.20.500.20.1.779ColumnnidPort7PeerMultiStateLocalread-onlycurrentNID Series card Detailed Link OAM Status for Port 7: Peer: Multiplexer State
1.3.6.1.4.1.4756.20.500.20.1.780ColumnnidPort7PeerParserStateLocalread-onlycurrentNID Series card Detailed Link OAM Status for Port 7: Peer: Multiplexer State
1.3.6.1.4.1.4756.20.500.20.1.781ColumnnidPort7PeerOUILocalread-onlycurrentNID Series card Detailed Link OAM Status for Port 7: Peer: Organizational Unique Identification
1.3.6.1.4.1.4756.20.500.20.1.782ColumnnidPort7PeerPDURevLocalread-onlycurrentNID Series card Detailed Link OAM Status for Port 7: Peer: PDU Revision
1.3.6.1.4.1.4756.20.500.20.1.783ColumnnidPort8PDUPermisionLocalread-onlycurrentNID Series card Detailed Link OAM Status for Port 8: PDU Permission
1.3.6.1.4.1.4756.20.500.20.1.784ColumnnidPort8DiscoveryStateLocalread-onlycurrentNID Series card Detailed Link OAM Status for Port 8: Discovery State
1.3.6.1.4.1.4756.20.500.20.1.785ColumnnidPort8PeerMACAddrLocalread-onlycurrentNID Series card Detailed Link OAM Status for Port 8: Discovery State
1.3.6.1.4.1.4756.20.500.20.1.786ColumnnidPort8LocalModeLocalread-onlycurrentNID Series card Detailed Link OAM Status for Port 8: Local: Mode
1.3.6.1.4.1.4756.20.500.20.1.787ColumnnidPort8LocalUnOperationLocalread-onlycurrentNID Series card Detailed Link OAM Status for Port 8: Local: Unidirectional Operation Support
1.3.6.1.4.1.4756.20.500.20.1.788ColumnnidPort8LocalRemoteLbLocalread-onlycurrentNID Series card Detailed Link OAM Status for Port 8: Local: Remote Loopback Support
1.3.6.1.4.1.4756.20.500.20.1.789ColumnnidPort8LocalLMLocalread-onlycurrentNID Series card Detailed Link OAM Status for Port 8: Local: Link Monitoring Support
1.3.6.1.4.1.4756.20.500.20.1.790ColumnnidPort8LocalMIBRetrievalLocalread-onlycurrentNID Series card Detailed Link OAM Status for Port 8: Local: MIB Retrieval Support
1.3.6.1.4.1.4756.20.500.20.1.791ColumnnidPort8LocalMTUSizeLocalread-onlycurrentNID Series card Detailed Link OAM Status for Port 8: Local: MTU Size
1.3.6.1.4.1.4756.20.500.20.1.792ColumnnidPort8LocalMultiStateLocalread-onlycurrentNID Series card Detailed Link OAM Status for Port 8: Local: Multiplexer State
1.3.6.1.4.1.4756.20.500.20.1.793ColumnnidPort8LocalParserStateLocalread-onlycurrentNID Series card Detailed Link OAM Status for Port 8: Local: Multiplexer State
1.3.6.1.4.1.4756.20.500.20.1.794ColumnnidPort8LocalOUILocalread-onlycurrentNID Series card Detailed Link OAM Status for Port 8: Local: Organizational Unique Identification
1.3.6.1.4.1.4756.20.500.20.1.795ColumnnidPort8LocalPDURevLocalread-onlycurrentNID Series card Detailed Link OAM Status for Port 8: Local: PDU Revision
1.3.6.1.4.1.4756.20.500.20.1.796ColumnnidPort8PeerModeLocalread-onlycurrentNID Series card Detailed Link OAM Status for Port 8: Peer: Mode
1.3.6.1.4.1.4756.20.500.20.1.797ColumnnidPort8PeerUnOperationLocalread-onlycurrentNID Series card Detailed Link OAM Status for Port 8: Peer: Unidirectional Operation Support
1.3.6.1.4.1.4756.20.500.20.1.798ColumnnidPort8PeerRemoteLbLocalread-onlycurrentNID Series card Detailed Link OAM Status for Port 8: Peer: Remote Loopback Support
1.3.6.1.4.1.4756.20.500.20.1.799ColumnnidPort8PeerLMLocalread-onlycurrentNID Series card Detailed Link OAM Status for Port 8: Peer: Link Monitoring Support
1.3.6.1.4.1.4756.20.500.20.1.800ColumnnidPort8PeerMIBRetrievalLocalread-onlycurrentNID Series card Detailed Link OAM Status for Port 8: Peer: MIB Retrieval Support
1.3.6.1.4.1.4756.20.500.20.1.801ColumnnidPort8PeerMTUSizeLocalread-onlycurrentNID Series card Detailed Link OAM Status for Port 8: Peer: MTU Size
1.3.6.1.4.1.4756.20.500.20.1.802ColumnnidPort8PeerMultiStateLocalread-onlycurrentNID Series card Detailed Link OAM Status for Port 8: Peer: Multiplexer State
1.3.6.1.4.1.4756.20.500.20.1.803ColumnnidPort8PeerParserStateLocalread-onlycurrentNID Series card Detailed Link OAM Status for Port 8: Peer: Multiplexer State
1.3.6.1.4.1.4756.20.500.20.1.804ColumnnidPort8PeerOUILocalread-onlycurrentNID Series card Detailed Link OAM Status for Port 8: Peer: Organizational Unique Identification
1.3.6.1.4.1.4756.20.500.20.1.805ColumnnidPort8PeerPDURevLocalread-onlycurrentNID Series card Detailed Link OAM Status for Port 8: Peer: PDU Revision
1.3.6.1.4.1.4756.20.500.20.1.806ColumnnidLoopProtectionEnableLocalread-writecurrentNID Series card Loop Protection Configuration: General Settings - Enable Loop Protection 0: Disable 1: Enable
1.3.6.1.4.1.4756.20.500.20.1.807ColumnnidLoopProtectionTxTimeLocalread-writecurrentNID Series card Loop Protection Configuration: General Settings - Transmission Time
1.3.6.1.4.1.4756.20.500.20.1.808ColumnnidLoopProtectionShutdownTimeLocalread-writecurrentNID Series card Loop Protection Configuration: General Settings - Shutdown Time
1.3.6.1.4.1.4756.20.500.20.1.809ColumnnidLoopProtectionPort1EnabledLocalread-writecurrentNID Series card Loop Protection Configuration for Port 1: Port Configuration - Enable 0: Disable 1: Enable
1.3.6.1.4.1.4756.20.500.20.1.810ColumnnidLoopProtectionPort1ActionLocalread-writecurrentNID Series card Loop Protection Configuration for Port 1: Port Configuration - Action 0: Shutdown Port 1: Shutdown Port And Log 2: Log Only
1.3.6.1.4.1.4756.20.500.20.1.811ColumnnidLoopProtectionPort1TxModeLocalread-writecurrentNID Series card Loop Protection Configuration for Port 1: Port Configuration - Tx Mode 0: Disable 1: Enable
1.3.6.1.4.1.4756.20.500.20.1.812ColumnnidLoopProtectionPort2EnabledLocalread-writecurrentNID Series card Loop Protection Configuration for Port 2: Port Configuration - Enable 0: Disable 1: Enable
1.3.6.1.4.1.4756.20.500.20.1.813ColumnnidLoopProtectionPort2ActionLocalread-writecurrentNID Series card Loop Protection Configuration for Port 2: Port Configuration - Action 0: Shutdown Port 1: Shutdown Port And Log 2: Log Only
1.3.6.1.4.1.4756.20.500.20.1.814ColumnnidLoopProtectionPort2TxModeLocalread-writecurrentNID Series card Loop Protection Configuration for Port 2: Port Configuration - Tx Mode 0: Disable 1: Enable
1.3.6.1.4.1.4756.20.500.20.1.815ColumnnidLoopProtectionPort3EnabledLocalread-writecurrentNID Series card Loop Protection Configuration for Port 3: Port Configuration - Enable 0: Disable 1: Enable
1.3.6.1.4.1.4756.20.500.20.1.816ColumnnidLoopProtectionPort3ActionLocalread-writecurrentNID Series card Loop Protection Configuration for Port 3: Port Configuration - Action 0: Shutdown Port 1: Shutdown Port And Log 2: Log Only
1.3.6.1.4.1.4756.20.500.20.1.817ColumnnidLoopProtectionPort3TxModeLocalread-writecurrentNID Series card Loop Protection Configuration for Port 3: Port Configuration - Tx Mode 0: Disable 1: Enable
1.3.6.1.4.1.4756.20.500.20.1.818ColumnnidLoopProtectionPort4EnabledLocalread-writecurrentNID Series card Loop Protection Configuration for Port 4: Port Configuration - Enable 0: Disable 1: Enable
1.3.6.1.4.1.4756.20.500.20.1.819ColumnnidLoopProtectionPort4ActionLocalread-writecurrentNID Series card Loop Protection Configuration for Port 4: Port Configuration - Action 0: Shutdown Port 1: Shutdown Port And Log 2: Log Only
1.3.6.1.4.1.4756.20.500.20.1.820ColumnnidLoopProtectionPort4TxModeLocalread-writecurrentNID Series card Loop Protection Configuration for Port 41: Port Configuration - Tx Mode 0: Disable 1: Enable
1.3.6.1.4.1.4756.20.500.20.1.821ColumnnidLoopProtectionPort5EnabledLocalread-writecurrentNID Series card Loop Protection Configuration for Port 5: Port Configuration - Enable 0: Disable 1: Enable
1.3.6.1.4.1.4756.20.500.20.1.822ColumnnidLoopProtectionPort5ActionLocalread-writecurrentNID Series card Loop Protection Configuration for Port 5: Port Configuration - Action 0: Shutdown Port 1: Shutdown Port And Log 2: Log Only
1.3.6.1.4.1.4756.20.500.20.1.823ColumnnidLoopProtectionPort5TxModeLocalread-writecurrentNID Series card Loop Protection Configuration for Port 5: Port Configuration - Tx Mode 0: Disable 1: Enable
1.3.6.1.4.1.4756.20.500.20.1.824ColumnnidLoopProtectionPort6EnabledLocalread-writecurrentNID Series card Loop Protection Configuration for Port 6: Port Configuration - Enable 0: Disable 1: Enable
1.3.6.1.4.1.4756.20.500.20.1.825ColumnnidLoopProtectionPort6ActionLocalread-writecurrentNID Series card Loop Protection Configuration for Port 6: Port Configuration - Action 0: Shutdown Port 1: Shutdown Port And Log 2: Log Only
1.3.6.1.4.1.4756.20.500.20.1.826ColumnnidLoopProtectionPort6TxModeLocalread-writecurrentNID Series card Loop Protection Configuration for Port 6: Port Configuration - Tx Mode 0: Disable 1: Enable
1.3.6.1.4.1.4756.20.500.20.1.827ColumnnidLoopProtectionPort7EnabledLocalread-writecurrentNID Series card Loop Protection Configuration for Port 7: Port Configuration - Enable 0: Disable 1: Enable
1.3.6.1.4.1.4756.20.500.20.1.828ColumnnidLoopProtectionPort7ActionLocalread-writecurrentNID Series card Loop Protection Configuration for Port 7: Port Configuration - Action 0: Shutdown Port 1: Shutdown Port And Log 2: Log Only
1.3.6.1.4.1.4756.20.500.20.1.829ColumnnidLoopProtectionPort7TxModeLocalread-writecurrentNID Series card Loop Protection Configuration for Port 7: Port Configuration - Tx Mode 0: Disable 1: Enable
1.3.6.1.4.1.4756.20.500.20.1.830ColumnnidLoopProtectionPort8EnabledLocalread-writecurrentNID Series card Loop Protection Configuration for Port 8: Port Configuration - Enable 0: Disable 1: Enable
1.3.6.1.4.1.4756.20.500.20.1.831ColumnnidLoopProtectionPort8ActionLocalread-writecurrentNID Series card Loop Protection Configuration for Port 8: Port Configuration - Action 0: Shutdown Port 1: Shutdown Port And Log 2: Log Only
1.3.6.1.4.1.4756.20.500.20.1.832ColumnnidLoopProtectionPort8TxModeLocalread-writecurrentNID Series card Loop Protection Configuration for Port 8: Port Configuration - Tx Mode 0: Disable 1: Enable
1.3.6.1.4.1.4756.20.500.20.1.833ColumnnidLoopProtectionPort1ActionStsLocalread-onlycurrentNID Series card Loop Protection Status for Port 1: Action
1.3.6.1.4.1.4756.20.500.20.1.834ColumnnidLoopProtectionPort1TransStsLocalread-onlycurrentNID Series card Loop Protection Status for Port 1: Transmit
1.3.6.1.4.1.4756.20.500.20.1.835ColumnnidLoopProtectionPort1LoopsStsLocalread-onlycurrentNID Series card Loop Protection Status for Port 1: Loops
1.3.6.1.4.1.4756.20.500.20.1.836ColumnnidLoopProtectionPort1StatusLocalread-onlycurrentNID Series card Loop Protection Status for Port 1: Status
1.3.6.1.4.1.4756.20.500.20.1.837ColumnnidLoopProtectionPort1LoopStsLocalread-onlycurrentNID Series card Loop Protection Status for Port 1: Loop
1.3.6.1.4.1.4756.20.500.20.1.838ColumnnidLoopProtectionPort1TimeOfLastLoopLocalread-onlycurrentNID Series card Loop Protection Status for Port 1: Time of Last Loop
1.3.6.1.4.1.4756.20.500.20.1.839ColumnnidLoopProtectionPort2ActionStsLocalread-onlycurrentNID Series card Loop Protection Status for Port 2: Action
1.3.6.1.4.1.4756.20.500.20.1.840ColumnnidLoopProtectionPort2TransStsLocalread-onlycurrentNID Series card Loop Protection Status for Port 2: Transmit
1.3.6.1.4.1.4756.20.500.20.1.841ColumnnidLoopProtectionPort2LoopsStsLocalread-onlycurrentNID Series card Loop Protection Status for Port 2: Loops
1.3.6.1.4.1.4756.20.500.20.1.842ColumnnidLoopProtectionPort2StatusLocalread-onlycurrentNID Series card Loop Protection Status for Port 2: Status
1.3.6.1.4.1.4756.20.500.20.1.843ColumnnidLoopProtectionPort2LoopStsLocalread-onlycurrentNID Series card Loop Protection Status for Port 2: Loop
1.3.6.1.4.1.4756.20.500.20.1.844ColumnnidLoopProtectionPort2TimeOfLastLoopLocalread-onlycurrentNID Series card Loop Protection Status for Port 2: Time of Last Loop
1.3.6.1.4.1.4756.20.500.20.1.845ColumnnidLoopProtectionPort3ActionStsLocalread-onlycurrentNID Series card Loop Protection Status for Port 3: Action
1.3.6.1.4.1.4756.20.500.20.1.846ColumnnidLoopProtectionPort3TransStsLocalread-onlycurrentNID Series card Loop Protection Status for Port 3: Transmit
1.3.6.1.4.1.4756.20.500.20.1.847ColumnnidLoopProtectionPort3LoopsStsLocalread-onlycurrentNID Series card Loop Protection Status for Port 3: Loops
1.3.6.1.4.1.4756.20.500.20.1.848ColumnnidLoopProtectionPort3StatusLocalread-onlycurrentNID Series card Loop Protection Status for Port 3: Status
1.3.6.1.4.1.4756.20.500.20.1.849ColumnnidLoopProtectionPort3LoopStsLocalread-onlycurrentNID Series card Loop Protection Status for Port 3: Loop
1.3.6.1.4.1.4756.20.500.20.1.850ColumnnidLoopProtectionPort3TimeOfLastLoopLocalread-onlycurrentNID Series card Loop Protection Status for Port 3: Time of Last Loop
1.3.6.1.4.1.4756.20.500.20.1.851ColumnnidLoopProtectionPort4ActionStsLocalread-onlycurrentNID Series card Loop Protection Status for Port 4: Action
1.3.6.1.4.1.4756.20.500.20.1.852ColumnnidLoopProtectionPort4TransStsLocalread-onlycurrentNID Series card Loop Protection Status for Port 4: Transmit
1.3.6.1.4.1.4756.20.500.20.1.853ColumnnidLoopProtectionPort4LoopsStsLocalread-onlycurrentNID Series card Loop Protection Status for Port 4: Loops
1.3.6.1.4.1.4756.20.500.20.1.854ColumnnidLoopProtectionPort4StatusLocalread-onlycurrentNID Series card Loop Protection Status for Port 4: Status
1.3.6.1.4.1.4756.20.500.20.1.855ColumnnidLoopProtectionPort4LoopStsLocalread-onlycurrentNID Series card Loop Protection Status for Port 4: Loop
1.3.6.1.4.1.4756.20.500.20.1.856ColumnnidLoopProtectionPort4TimeOfLastLoopLocalread-onlycurrentNID Series card Loop Protection Status for Port 4: Time of Last Loop
1.3.6.1.4.1.4756.20.500.20.1.857ColumnnidLoopProtectionPort5ActionStsLocalread-onlycurrentNID Series card Loop Protection Status for Port 5: Action
1.3.6.1.4.1.4756.20.500.20.1.858ColumnnidLoopProtectionPort5TransStsLocalread-onlycurrentNID Series card Loop Protection Status for Port 5: Transmit
1.3.6.1.4.1.4756.20.500.20.1.859ColumnnidLoopProtectionPort5LoopsStsLocalread-onlycurrentNID Series card Loop Protection Status for Port 5: Loops
1.3.6.1.4.1.4756.20.500.20.1.860ColumnnidLoopProtectionPort5StatusLocalread-onlycurrentNID Series card Loop Protection Status for Port 5: Status
1.3.6.1.4.1.4756.20.500.20.1.861ColumnnidLoopProtectionPort5LoopStsLocalread-onlycurrentNID Series card Loop Protection Status for Port 5: Loop
1.3.6.1.4.1.4756.20.500.20.1.862ColumnnidLoopProtectionPort5TimeOfLastLoopLocalread-onlycurrentNID Series card Loop Protection Status for Port 5: Time of Last Loop
1.3.6.1.4.1.4756.20.500.20.1.863ColumnnidLoopProtectionPort6ActionStsLocalread-onlycurrentNID Series card Loop Protection Status for Port 6: Action
1.3.6.1.4.1.4756.20.500.20.1.864ColumnnidLoopProtectionPort6TransStsLocalread-onlycurrentNID Series card Loop Protection Status for Port 6: Transmit
1.3.6.1.4.1.4756.20.500.20.1.865ColumnnidLoopProtectionPort6LoopsStsLocalread-onlycurrentNID Series card Loop Protection Status for Port 6: Loops
1.3.6.1.4.1.4756.20.500.20.1.866ColumnnidLoopProtectionPort6StatusLocalread-onlycurrentNID Series card Loop Protection Status for Port 64: Status
1.3.6.1.4.1.4756.20.500.20.1.867ColumnnidLoopProtectionPort6LoopStsLocalread-onlycurrentNID Series card Loop Protection Status for Port 64: Loop
1.3.6.1.4.1.4756.20.500.20.1.868ColumnnidLoopProtectionPort6TimeOfLastLoopLocalread-onlycurrentNID Series card Loop Protection Status for Port 6: Time of Last Loop
1.3.6.1.4.1.4756.20.500.20.1.869ColumnnidLoopProtectionPort7ActionStsLocalread-onlycurrentNID Series card Loop Protection Status for Port 7: Action
1.3.6.1.4.1.4756.20.500.20.1.870ColumnnidLoopProtectionPort7TransStsLocalread-onlycurrentNID Series card Loop Protection Status for Port 7: Transmit
1.3.6.1.4.1.4756.20.500.20.1.871ColumnnidLoopProtectionPort7LoopsStsLocalread-onlycurrentNID Series card Loop Protection Status for Port 7: Loops
1.3.6.1.4.1.4756.20.500.20.1.872ColumnnidLoopProtectionPort7StatusLocalread-onlycurrentNID Series card Loop Protection Status for Port 7: Status
1.3.6.1.4.1.4756.20.500.20.1.873ColumnnidLoopProtectionPort7LoopStsLocalread-onlycurrentNID Series card Loop Protection Status for Port 7: Loop
1.3.6.1.4.1.4756.20.500.20.1.874ColumnnidLoopProtectionPort7TimeOfLastLoopLocalread-onlycurrentNID Series card Loop Protection Status for Port 7: Time of Last Loop
1.3.6.1.4.1.4756.20.500.20.1.875ColumnnidLoopProtectionPort8ActionStsLocalread-onlycurrentNID Series card Loop Protection Status for Port 8: Action
1.3.6.1.4.1.4756.20.500.20.1.876ColumnnidLoopProtectionPort8TransStsLocalread-onlycurrentNID Series card Loop Protection Status for Port 8: Transmit
1.3.6.1.4.1.4756.20.500.20.1.877ColumnnidLoopProtectionPort8LoopsStsLocalread-onlycurrentNID Series card Loop Protection Status for Port 8: Loops
1.3.6.1.4.1.4756.20.500.20.1.878ColumnnidLoopProtectionPort8StatusLocalread-onlycurrentNID Series card Loop Protection Status for Port 8: Status
1.3.6.1.4.1.4756.20.500.20.1.879ColumnnidLoopProtectionPort8LoopStsLocalread-onlycurrentNID Series card Loop Protection Status for Port 8: Loop
1.3.6.1.4.1.4756.20.500.20.1.880ColumnnidLoopProtectionPort8TimeOfLastLoopLocalread-onlycurrentNID Series card Loop Protection Status for Port 8: Time of Last Loop
1.3.6.1.4.1.4756.20.500.20.1.881ColumnniduRingInstanceAddLocalread-writecurrentNID Series card Add a new uRing Instance. Syntax: <Instance ID> <ring|sub|chain> <port east> <port west> Instance ID must be either 1 or 2 port east , the valu…
1.3.6.1.4.1.4756.20.500.20.1.882ColumnniduRingInstanceDeleteLocalread-writecurrentNID Series card Delete a uRing Instance. Syntax: <uRing Instance>
1.3.6.1.4.1.4756.20.500.20.1.883ColumnniduRingInst1IDLocalread-onlycurrentNID Series card u-Ring instance1 ID
1.3.6.1.4.1.4756.20.500.20.1.884ColumnniduRingInst1typeLocalread-onlycurrentNID Series card u-Ring instance1 type 0: u-Ring 1: Sub-Ring 2: u-Chain
1.3.6.1.4.1.4756.20.500.20.1.885ColumnniduRingInst1masterLocalread-writecurrentNID Series card u-Ring instance1 master 0: No 1: Yes
1.3.6.1.4.1.4756.20.500.20.1.886ColumnniduRingInst1EastPortLocalread-onlycurrentNID Series card u-Ring instance1 east port
1.3.6.1.4.1.4756.20.500.20.1.887ColumnniduRingInst1EastEdgeLocalread-writecurrentNID Series card u-Ring instance1 east edge 0: No 1: Yes
1.3.6.1.4.1.4756.20.500.20.1.888ColumnniduRingInst1WestPortLocalread-onlycurrentNID Series card u-Ring instance1 west port
1.3.6.1.4.1.4756.20.500.20.1.889ColumnniduRingInst1WestEdgeLocalread-writecurrentNID Series card u-Ring instance1 west edge 0: No 1: Yes
1.3.6.1.4.1.4756.20.500.20.1.890ColumnniduRingInst2IDLocalread-onlycurrentNID Series card u-Ring instance2 ID
1.3.6.1.4.1.4756.20.500.20.1.891ColumnniduRingInst2typeLocalread-onlycurrentNID Series card u-Ring instance2 type 0: u-Ring 1: Sub-Ring 2: u-Chain
1.3.6.1.4.1.4756.20.500.20.1.892ColumnniduRingInst2masterLocalread-writecurrentNID Series card u-Ring instance2 master 0: No 1: Yes
1.3.6.1.4.1.4756.20.500.20.1.893ColumnniduRingInst2EastPortLocalread-onlycurrentNID Series card u-Ring instance2 east port
1.3.6.1.4.1.4756.20.500.20.1.894ColumnniduRingInst2EastEdgeLocalread-writecurrentNID Series card u-Ring instance2 east edge 0: No 1: Yes
1.3.6.1.4.1.4756.20.500.20.1.895ColumnniduRingInst2WestPortLocalread-onlycurrentNID Series card u-Ring instance2 west port
1.3.6.1.4.1.4756.20.500.20.1.896ColumnniduRingInst2WestEdgeLocalread-writecurrentNID Series card u-Ring instance2 west edge 0: No 1: Yes
1.3.6.1.4.1.4756.20.500.20.1.897ColumnniduRingInst3IDLocalread-onlycurrentNID Series card u-Ring instance3 ID
1.3.6.1.4.1.4756.20.500.20.1.898ColumnniduRingInst3typeLocalread-onlycurrentNID Series card u-Ring instance3 type 0: u-Ring 1: Sub-Ring 2: u-Chain
1.3.6.1.4.1.4756.20.500.20.1.899ColumnniduRingInst3masterLocalread-writecurrentNID Series card u-Ring instance3 master 0: No 1: Yes
1.3.6.1.4.1.4756.20.500.20.1.900ColumnniduRingInst3EastPortLocalread-onlycurrentNID Series card u-Ring instance3 east port
1.3.6.1.4.1.4756.20.500.20.1.901ColumnniduRingInst3EastEdgeLocalread-writecurrentNID Series card u-Ring instance3 east edge 0: No 1: Yes
1.3.6.1.4.1.4756.20.500.20.1.902ColumnniduRingInst3WestPortLocalread-onlycurrentNID Series card u-Ring instance3 west port
1.3.6.1.4.1.4756.20.500.20.1.903ColumnniduRingInst3WestEdgeLocalread-writecurrentNID Series card u-Ring instance3 west edge 0: No 1: Yes
1.3.6.1.4.1.4756.20.500.20.1.904ColumnniduRingInst4IDLocalread-onlycurrentNID Series card u-Ring instance4 ID
1.3.6.1.4.1.4756.20.500.20.1.905ColumnniduRingInst4typeLocalread-onlycurrentNID Series card u-Ring instance4 type 0: u-Ring 1: Sub-Ring 2: u-Chain
1.3.6.1.4.1.4756.20.500.20.1.906ColumnniduRingInst4masterLocalread-writecurrentNID Series card u-Ring instance4 master 0: No 1: Yes
1.3.6.1.4.1.4756.20.500.20.1.907ColumnniduRingInst4EastPortLocalread-onlycurrentNID Series card u-Ring instance4 east port
1.3.6.1.4.1.4756.20.500.20.1.908ColumnniduRingInst4EastEdgeLocalread-writecurrentNID Series card u-Ring instance4 east edge 0: No 1: Yes
1.3.6.1.4.1.4756.20.500.20.1.909ColumnniduRingInst4WestPortLocalread-onlycurrentNID Series card u-Ring instance4 west port
1.3.6.1.4.1.4756.20.500.20.1.910ColumnniduRingInst4WestEdgeLocalread-writecurrentNID Series card u-Ring instance4 west edge 0: No 1: Yes
1.3.6.1.4.1.4756.20.500.20.1.911ColumnniduRingInst1IDstsLocalread-onlycurrentNID Series card u-Ring Instance1 ID status
1.3.6.1.4.1.4756.20.500.20.1.912ColumnniduRingInst1typestsLocalread-onlycurrentNID Series card u-Ring Type status
1.3.6.1.4.1.4756.20.500.20.1.913ColumnniduRingInst1rolestsLocalread-onlycurrentNID Series card u-Ring Role status
1.3.6.1.4.1.4756.20.500.20.1.914ColumnniduRingInst1EastPortstsLocalread-onlycurrentNID Series card u-Ring East port status
1.3.6.1.4.1.4756.20.500.20.1.915ColumnniduRingInst1EaststsLocalread-onlycurrentNID Series card u-Ring East status
1.3.6.1.4.1.4756.20.500.20.1.916ColumnniduRingInst1EastEdgestsLocalread-onlycurrentNID Series card u-Ring East edge status
1.3.6.1.4.1.4756.20.500.20.1.917ColumnniduRingInst1WestPortstsLocalread-onlycurrentNID Series card u-Ring West edge status
1.3.6.1.4.1.4756.20.500.20.1.918ColumnniduRingInst1WeststsLocalread-onlycurrentNID Series card u-Ring West status
1.3.6.1.4.1.4756.20.500.20.1.919ColumnniduRingInst1WestEdgestsLocalread-onlycurrentNID Series card u-Ring West status
1.3.6.1.4.1.4756.20.500.20.1.920ColumnniduRingInst1healthystsLocalread-onlycurrentNID Series card u-Ring healthy status None Fine Fault
1.3.6.1.4.1.4756.20.500.20.1.921ColumnniduRingInst2IDstsLocalread-onlycurrentNID Series card u-Ring Instance2 ID status
1.3.6.1.4.1.4756.20.500.20.1.922ColumnniduRingInst2typestsLocalread-onlycurrentNID Series card u-Ring Type status
1.3.6.1.4.1.4756.20.500.20.1.923ColumnniduRingInst2rolestsLocalread-onlycurrentNID Series card u-Ring Role status
1.3.6.1.4.1.4756.20.500.20.1.924ColumnniduRingInst2EastPortstsLocalread-onlycurrentNID Series card u-Ring East port status
1.3.6.1.4.1.4756.20.500.20.1.925ColumnniduRingInst2EaststsLocalread-onlycurrentNID Series card u-Ring East status
1.3.6.1.4.1.4756.20.500.20.1.926ColumnniduRingInst2EastEdgestsLocalread-onlycurrentNID Series card u-Ring East edge status
1.3.6.1.4.1.4756.20.500.20.1.927ColumnniduRingInst2WestPortstsLocalread-onlycurrentNID Series card u-Ring West edge status
1.3.6.1.4.1.4756.20.500.20.1.928ColumnniduRingInst2WeststsLocalread-onlycurrentNID Series card u-Ring West status
1.3.6.1.4.1.4756.20.500.20.1.929ColumnniduRingInst2WestEdgestsLocalread-onlycurrentNID Series card u-Ring West status
1.3.6.1.4.1.4756.20.500.20.1.930ColumnniduRingInst2healthystsLocalread-onlycurrentNID Series card u-Ring healthy status None Fine Fault
1.3.6.1.4.1.4756.20.500.20.1.931ColumnniduRingInst3IDstsLocalread-onlycurrentNID Series card u-Ring Instance3 ID status
1.3.6.1.4.1.4756.20.500.20.1.932ColumnniduRingInst3typestsLocalread-onlycurrentNID Series card u-Ring Type status
1.3.6.1.4.1.4756.20.500.20.1.933ColumnniduRingInst3rolestsLocalread-onlycurrentNID Series card u-Ring Role status
1.3.6.1.4.1.4756.20.500.20.1.934ColumnniduRingInst3EastPortstsLocalread-onlycurrentNID Series card u-Ring East port status
1.3.6.1.4.1.4756.20.500.20.1.935ColumnniduRingInst3EaststsLocalread-onlycurrentNID Series card u-Ring East status
1.3.6.1.4.1.4756.20.500.20.1.936ColumnniduRingInst3EastEdgestsLocalread-onlycurrentNID Series card u-Ring East edge status
1.3.6.1.4.1.4756.20.500.20.1.937ColumnniduRingInst3WestPortstsLocalread-onlycurrentNID Series card u-Ring West edge status
1.3.6.1.4.1.4756.20.500.20.1.938ColumnniduRingInst3WeststsLocalread-onlycurrentNID Series card u-Ring West status
1.3.6.1.4.1.4756.20.500.20.1.939ColumnniduRingInst3WestEdgestsLocalread-onlycurrentNID Series card u-Ring West status
1.3.6.1.4.1.4756.20.500.20.1.940ColumnniduRingInst3healthystsLocalread-onlycurrentNID Series card u-Ring healthy status None Fine Fault
1.3.6.1.4.1.4756.20.500.20.1.941ColumnniduRingInst4IDstsLocalread-onlycurrentNID Series card u-Ring Instance4 ID status
1.3.6.1.4.1.4756.20.500.20.1.942ColumnniduRingInst4typestsLocalread-onlycurrentNID Series card u-Ring Type status
1.3.6.1.4.1.4756.20.500.20.1.943ColumnniduRingInst4rolestsLocalread-onlycurrentNID Series card u-Ring Role status
1.3.6.1.4.1.4756.20.500.20.1.944ColumnniduRingInst4EastPortstsLocalread-onlycurrentNID Series card u-Ring East port status
1.3.6.1.4.1.4756.20.500.20.1.945ColumnniduRingInst4EaststsLocalread-onlycurrentNID Series card u-Ring East status
1.3.6.1.4.1.4756.20.500.20.1.946ColumnniduRingInst4EastEdgestsLocalread-onlycurrentNID Series card u-Ring East edge status
1.3.6.1.4.1.4756.20.500.20.1.947ColumnniduRingInst4WestPortstsLocalread-onlycurrentNID Series card u-Ring West edge status
1.3.6.1.4.1.4756.20.500.20.1.948ColumnniduRingInst4WeststsLocalread-onlycurrentNID Series card u-Ring West status
1.3.6.1.4.1.4756.20.500.20.1.949ColumnniduRingInst4WestEdgestsLocalread-onlycurrentNID Series card u-Ring West status
1.3.6.1.4.1.4756.20.500.20.1.950ColumnniduRingInst4healthystsLocalread-onlycurrentNID Series card u-Ring healthy status None Fine Fault
1.3.6.1.4.1.4756.20.500.20.1.951ColumnnidSTPProtocolVersionLocalread-writecurrentNID Series card STP Bridge Configuration: Basic Settings - Protocol Version 0: STP 1: RSTP 2: MSTP
1.3.6.1.4.1.4756.20.500.20.1.952ColumnnidSTPBridgePriorityLocalread-writecurrentNID Series card STP Bridge Configuration: Basic Settings - Bridge Priority 0: 0 1: 4096 2: 8192 3: 12288 4: 16384 5: 20480 6: 24576 7: 28672 8: 32768 9: 36864 …
1.3.6.1.4.1.4756.20.500.20.1.953ColumnnidSTPForwardDelayLocalread-writecurrentNID Series card STP Bridge Configuration: Basic Settings - Forward Delay
1.3.6.1.4.1.4756.20.500.20.1.954ColumnnidSTPMaxAgeLocalread-writecurrentNID Series card STP Bridge Configuration: Basic Settings - Max Age
1.3.6.1.4.1.4756.20.500.20.1.955ColumnnidSTPMaximumHopCountLocalread-writecurrentNID Series card STP Bridge Configuration: Basic Settings - Maximum Hop Count
1.3.6.1.4.1.4756.20.500.20.1.956ColumnnidSTPTransmitHoldCountLocalread-writecurrentNID Series card STP Bridge Configuration: Basic Settings - Transmit Hold Count
1.3.6.1.4.1.4756.20.500.20.1.957ColumnnidSTPEdgePortBPDUFilteringLocalread-writecurrentNID Series card STP Bridge Configuration: Advanced Settings - Edge Port BPDU Filtering 0: Off 1: On
1.3.6.1.4.1.4756.20.500.20.1.958ColumnnidSTPEdgePortBPDUGuardLocalread-writecurrentNID Series card STP Bridge Configuration: Advanced Settings - Edge Port BPDU Guard 0: Off 1: On
1.3.6.1.4.1.4756.20.500.20.1.959ColumnnidSTPPortErrorRecoveryTimeoutLocalread-writecurrentNID Series card STP Bridge Configuration: Advanced Settings - Port Error Recovery Timeout 0: Off 1: On
1.3.6.1.4.1.4756.20.500.20.1.960ColumnnidMSTIConfigurationNameLocalread-writecurrentNID Series card MSTI Configuration: Configuration Identification - Configuration Name
1.3.6.1.4.1.4756.20.500.20.1.961ColumnnidMSTIConfigurationRevisionLocalread-writecurrentNID Series card MSTI Configuration: Configuration Identification - Configuration Revision
1.3.6.1.4.1.4756.20.500.20.1.962ColumnnidMSTI1VLANsMappingLocalread-writecurrentNID Series card MSTI Configuration: MSTI Mapping - MSTI 1
1.3.6.1.4.1.4756.20.500.20.1.963ColumnnidMSTI2VLANsMappingLocalread-writecurrentNID Series card MSTI Configuration: MSTI Mapping - MSTI 2
1.3.6.1.4.1.4756.20.500.20.1.964ColumnnidMSTI3VLANsMappingLocalread-writecurrentNID Series card MSTI Configuration: MSTI Mapping - MSTI 3
1.3.6.1.4.1.4756.20.500.20.1.965ColumnnidMSTI4VLANsMappingLocalread-writecurrentNID Series card MSTI Configuration: MSTI Mapping - MSTI 4
1.3.6.1.4.1.4756.20.500.20.1.966ColumnnidMSTI5VLANsMappingLocalread-writecurrentNID Series card MSTI Configuration: MSTI Mapping - MSTI 5
1.3.6.1.4.1.4756.20.500.20.1.967ColumnnidMSTI6VLANsMappingLocalread-writecurrentNID Series card MSTI Configuration: MSTI Mapping - MSTI 6
1.3.6.1.4.1.4756.20.500.20.1.968ColumnnidMSTI7VLANsMappingLocalread-writecurrentNID Series card MSTI Configuration: MSTI Mapping - MSTI 7
1.3.6.1.4.1.4756.20.500.20.1.969ColumnnidMSTI8VLANsMappingLocalread-writecurrentNID Series card MSTI Configuration: MSTI Mapping - MSTI 8
1.3.6.1.4.1.4756.20.500.20.1.970ColumnnidMSTI9VLANsMappingLocalread-writecurrentNID Series card MSTI Configuration: MSTI Mapping - MSTI 9
1.3.6.1.4.1.4756.20.500.20.1.971ColumnnidMSTI10VLANsMappingLocalread-writecurrentNID Series card MSTI Configuration: MSTI Mapping - MSTI 10
1.3.6.1.4.1.4756.20.500.20.1.972ColumnnidMSTI11VLANsMappingLocalread-writecurrentNID Series card MSTI Configuration: MSTI Mapping - MSTI 11
1.3.6.1.4.1.4756.20.500.20.1.973ColumnnidMSTI12VLANsMappingLocalread-writecurrentNID Series card MSTI Configuration: MSTI Mapping - MSTI 12
1.3.6.1.4.1.4756.20.500.20.1.974ColumnnidMSTI13VLANsMappingLocalread-writecurrentNID Series card MSTI Configuration: MSTI Mapping - MSTI 13
1.3.6.1.4.1.4756.20.500.20.1.975ColumnnidMSTI14VLANsMappingLocalread-writecurrentNID Series card MSTI Configuration: MSTI Mapping - MSTI 14
1.3.6.1.4.1.4756.20.500.20.1.976ColumnnidMSTI15VLANsMappingLocalread-writecurrentNID Series card MSTI Configuration: MSTI Mapping - MSTI 15
1.3.6.1.4.1.4756.20.500.20.1.977ColumnnidCISTAggregatedSTPEnabledLocalread-writecurrentNID Series card STP CIST Port Configuration: CIST Aggregated Port Configuration - STP Enabled
1.3.6.1.4.1.4756.20.500.20.1.978ColumnnidCISTAggregatedPathCostLocalread-writecurrentNID Series card STP CIST Port Configuration: CIST Aggregated Port Configuration - Path Cost Valid values are in the range 0 to 200000000. Setting 0 means Auto …
1.3.6.1.4.1.4756.20.500.20.1.979ColumnnidCISTAggregatedPriorityLocalread-writecurrentNID Series card STP CIST Port Configuration: CIST Aggregated Port Configuration - Priority
1.3.6.1.4.1.4756.20.500.20.1.980ColumnnidCISTAggregatedAdminEdgeLocalread-writecurrentNID Series card STP CIST Port Configuration: CIST Aggregated Port Configuration - STP Enabled 0: Non-edge 1: Edge
1.3.6.1.4.1.4756.20.500.20.1.981ColumnnidCISTAggregatedAutoEdgeLocalread-writecurrentNID Series card STP CIST Port Configuration: CIST Aggregated Port Configuration - Auto Edge 0: Non-edge 1: Edge
1.3.6.1.4.1.4756.20.500.20.1.982ColumnnidCISTAggregatedRestrictedRoleLocalread-writecurrentNID Series card STP CIST Port Configuration: CIST Aggregated Port Configuration - Restricted Role 0: Non-edge 1: Edge
1.3.6.1.4.1.4756.20.500.20.1.983ColumnnidCISTAggregatedRestrictedTCNLocalread-writecurrentNID Series card STP CIST Port Configuration: CIST Aggregated Port Configuration - Restricted TCN 0: Non-edge 1: Edge
1.3.6.1.4.1.4756.20.500.20.1.984ColumnnidCISTAggregatedBPDUGuardLocalread-writecurrentNID Series card STP CIST Port Configuration: CIST Aggregated Port Configuration - BPDU Guard 0: Non-edge 1: Edge
1.3.6.1.4.1.4756.20.500.20.1.985ColumnnidCISTAggregatedPointToPointLocalread-writecurrentNID Series card STP CIST Port Configuration: CIST Aggregated Port Configuration - Point-to-point 0: Forced True 1: Forced False 2: Auto
1.3.6.1.4.1.4756.20.500.20.1.986ColumnnidCISTPort1STPEnabledLocalread-writecurrentNID Series card STP CIST Port Configuration: CIST Normal Port1 Configuration - STP Enabled
1.3.6.1.4.1.4756.20.500.20.1.987ColumnnidCISTPort1PathCostLocalread-writecurrentNID Series card STP CIST Port Configuration: CIST Normal Port1 Configuration - Path Cost Valid values are in the range 0 to 200000000. Setting 0 means Auto pat…
1.3.6.1.4.1.4756.20.500.20.1.988ColumnnidCISTPort1PriorityLocalread-writecurrentNID Series card STP CIST Port Configuration: CIST Normal Port1 Configuration - Priority
1.3.6.1.4.1.4756.20.500.20.1.989ColumnnidCISTPort1AdminEdgeLocalread-writecurrentNID Series card STP CIST Port Configuration: CIST Normal Port1 Configuration - STP Enabled 0: Non-edge 1: Edge
1.3.6.1.4.1.4756.20.500.20.1.990ColumnnidCISTPort1AutoEdgeLocalread-writecurrentNID Series card STP CIST Port Configuration: CIST Normal Port1 Configuration - Auto Edge 0: Non-edge 1: Edge
1.3.6.1.4.1.4756.20.500.20.1.991ColumnnidCISTPort1RestrictedRoleLocalread-writecurrentNID Series card STP CIST Port Configuration: CIST Normal Port1 Configuration - Restricted Role 0: Non-edge 1: Edge
1.3.6.1.4.1.4756.20.500.20.1.992ColumnnidCISTPort1RestrictedTCNLocalread-writecurrentNID Series card STP CIST Port Configuration: CIST Normal Port1 Configuration - Restricted TCN 0: Non-edge 1: Edge
1.3.6.1.4.1.4756.20.500.20.1.993ColumnnidCISTPort1BPDUGuardLocalread-writecurrentNID Series card STP CIST Port Configuration: CIST Normal Port1 Configuration - BPDU Guard 0: Non-edge 1: Edge
1.3.6.1.4.1.4756.20.500.20.1.994ColumnnidCISTPort1PointToPointLocalread-writecurrentNID Series card STP CIST Port Configuration: CIST Normal Port1 Configuration - Point-to-point 0: Forced True 1: Forced False 2: Auto
1.3.6.1.4.1.4756.20.500.20.1.995ColumnnidCISTPort2STPEnabledLocalread-writecurrentNID Series card STP CIST Port Configuration: CIST Normal Port2 Configuration - STP Enabled
1.3.6.1.4.1.4756.20.500.20.1.996ColumnnidCISTPort2PathCostLocalread-writecurrentNID Series card STP CIST Port Configuration: CIST Normal Port2 Configuration - Path Cost Valid values are in the range 0 to 200000000. Setting 0 means Auto pat…
1.3.6.1.4.1.4756.20.500.20.1.997ColumnnidCISTPort2PriorityLocalread-writecurrentNID Series card STP CIST Port Configuration: CIST Normal Port2 Configuration - Priority
1.3.6.1.4.1.4756.20.500.20.1.998ColumnnidCISTPort2AdminEdgeLocalread-writecurrentNID Series card STP CIST Port Configuration: CIST Normal Port2 Configuration - STP Enabled 0: Non-edge 1: Edge
1.3.6.1.4.1.4756.20.500.20.1.999ColumnnidCISTPort2AutoEdgeLocalread-writecurrentNID Series card STP CIST Port Configuration: CIST Normal Port2 Configuration - Auto Edge 0: Non-edge 1: Edge
1.3.6.1.4.1.4756.20.500.20.1.1000ColumnnidCISTPort2RestrictedRoleLocalread-writecurrentNID Series card STP CIST Port Configuration: CIST Normal Port2 Configuration - Restricted Role 0: Non-edge 1: Edge
1.3.6.1.4.1.4756.20.500.20.1.1001ColumnnidCISTPort2RestrictedTCNLocalread-writecurrentNID Series card STP CIST Port Configuration: CIST Normal Port2 Configuration - Restricted TCN 0: Non-edge 1: Edge
1.3.6.1.4.1.4756.20.500.20.1.1002ColumnnidCISTPort2BPDUGuardLocalread-writecurrentNID Series card STP CIST Port Configuration: CIST Normal Port2 Configuration - BPDU Guard 0: Non-edge 1: Edge
1.3.6.1.4.1.4756.20.500.20.1.1003ColumnnidCISTPort2PointToPointLocalread-writecurrentNID Series card STP CIST Port Configuration: CIST Normal Port2 Configuration - Point-to-point 0: Forced True 1: Forced False 2: Auto
1.3.6.1.4.1.4756.20.500.20.1.1004ColumnnidCISTPort3STPEnabledLocalread-writecurrentNID Series card STP CIST Port Configuration: CIST Normal Port3 Configuration - STP Enabled
1.3.6.1.4.1.4756.20.500.20.1.1005ColumnnidCISTPort3PathCostLocalread-writecurrentNID Series card STP CIST Port Configuration: CIST Normal Port3 Configuration - Path Cost Valid values are in the range 0 to 200000000. Setting 0 means Auto pat…
1.3.6.1.4.1.4756.20.500.20.1.1006ColumnnidCISTPort3PriorityLocalread-writecurrentNID Series card STP CIST Port Configuration: CIST Normal Port3 Configuration - Priority
1.3.6.1.4.1.4756.20.500.20.1.1007ColumnnidCISTPort3AdminEdgeLocalread-writecurrentNID Series card STP CIST Port Configuration: CIST Normal Port3 Configuration - STP Enabled 0: Non-edge 1: Edge
1.3.6.1.4.1.4756.20.500.20.1.1008ColumnnidCISTPort3AutoEdgeLocalread-writecurrentNID Series card STP CIST Port Configuration: CIST Normal Port3 Configuration - Auto Edge 0: Non-edge 1: Edge
1.3.6.1.4.1.4756.20.500.20.1.1009ColumnnidCISTPort3RestrictedRoleLocalread-writecurrentNID Series card STP CIST Port Configuration: CIST Normal Port3 Configuration - Restricted Role 0: Non-edge 1: Edge
1.3.6.1.4.1.4756.20.500.20.1.1010ColumnnidCISTPort3RestrictedTCNLocalread-writecurrentNID Series card STP CIST Port Configuration: CIST Normal Port3 Configuration - Restricted TCN 0: Non-edge 1: Edge
1.3.6.1.4.1.4756.20.500.20.1.1011ColumnnidCISTPort3BPDUGuardLocalread-writecurrentNID Series card STP CIST Port Configuration: CIST Normal Port3 Configuration - BPDU Guard 0: Non-edge 1: Edge
1.3.6.1.4.1.4756.20.500.20.1.1012ColumnnidCISTPort3PointToPointLocalread-writecurrentNID Series card STP CIST Port Configuration: CIST Normal Port3 Configuration - Point-to-point 0: Forced True 1: Forced False 2: Auto
1.3.6.1.4.1.4756.20.500.20.1.1013ColumnnidCISTPort4STPEnabledLocalread-writecurrentNID Series card STP CIST Port Configuration: CIST Normal Port4 Configuration - STP Enabled
1.3.6.1.4.1.4756.20.500.20.1.1014ColumnnidCISTPort4PathCostLocalread-writecurrentNID Series card STP CIST Port Configuration: CIST Normal Port4 Configuration - Path Cost Valid values are in the range 0 to 200000000. Setting 0 means Auto pat…
1.3.6.1.4.1.4756.20.500.20.1.1015ColumnnidCISTPort4PriorityLocalread-writecurrentNID Series card STP CIST Port Configuration: CIST Normal Port4 Configuration - Priority
1.3.6.1.4.1.4756.20.500.20.1.1016ColumnnidCISTPort4AdminEdgeLocalread-writecurrentNID Series card STP CIST Port Configuration: CIST Normal Port4 Configuration - STP Enabled 0: Non-edge 1: Edge
1.3.6.1.4.1.4756.20.500.20.1.1017ColumnnidCISTPort4AutoEdgeLocalread-writecurrentNID Series card STP CIST Port Configuration: CIST Normal Port4 Configuration - Auto Edge 0: Non-edge 1: Edge
1.3.6.1.4.1.4756.20.500.20.1.1018ColumnnidCISTPort4RestrictedRoleLocalread-writecurrentNID Series card STP CIST Port Configuration: CIST Normal Port4 Configuration - Restricted Role 0: Non-edge 1: Edge
1.3.6.1.4.1.4756.20.500.20.1.1019ColumnnidCISTPort4RestrictedTCNLocalread-writecurrentNID Series card STP CIST Port Configuration: CIST Normal Port4 Configuration - Restricted TCN 0: Non-edge 1: Edge
1.3.6.1.4.1.4756.20.500.20.1.1020ColumnnidCISTPort4BPDUGuardLocalread-writecurrentNID Series card STP CIST Port Configuration: CIST Normal Port4 Configuration - BPDU Guard 0: Non-edge 1: Edge
1.3.6.1.4.1.4756.20.500.20.1.1021ColumnnidCISTPort4PointToPointLocalread-writecurrentNID Series card STP CIST Port Configuration: CIST Normal Port4 Configuration - Point-to-point 0: Forced True 1: Forced False 2: Auto
1.3.6.1.4.1.4756.20.500.20.1.1022ColumnnidCISTPort5STPEnabledLocalread-writecurrentNID Series card STP CIST Port Configuration: CIST Normal Port5 Configuration - STP Enabled
1.3.6.1.4.1.4756.20.500.20.1.1023ColumnnidCISTPort5PathCostLocalread-writecurrentNID Series card STP CIST Port Configuration: CIST Normal Port5 Configuration - Path Cost Valid values are in the range 0 to 200000000. Setting 0 means Auto pat…
1.3.6.1.4.1.4756.20.500.20.1.1024ColumnnidCISTPort5PriorityLocalread-writecurrentNID Series card STP CIST Port Configuration: CIST Normal Port5 Configuration - Priority
1.3.6.1.4.1.4756.20.500.20.1.1025ColumnnidCISTPort5AdminEdgeLocalread-writecurrentNID Series card STP CIST Port Configuration: CIST Normal Port5 Configuration - STP Enabled 0: Non-edge 1: Edge
1.3.6.1.4.1.4756.20.500.20.1.1026ColumnnidCISTPort5AutoEdgeLocalread-writecurrentNID Series card STP CIST Port Configuration: CIST Normal Port5 Configuration - Auto Edge 0: Non-edge 1: Edge
1.3.6.1.4.1.4756.20.500.20.1.1027ColumnnidCISTPort5RestrictedRoleLocalread-writecurrentNID Series card STP CIST Port Configuration: CIST Normal Port5 Configuration - Restricted Role 0: Non-edge 1: Edge
1.3.6.1.4.1.4756.20.500.20.1.1028ColumnnidCISTPort5RestrictedTCNLocalread-writecurrentNID Series card STP CIST Port Configuration: CIST Normal Port5 Configuration - Restricted TCN 0: Non-edge 1: Edge
1.3.6.1.4.1.4756.20.500.20.1.1029ColumnnidCISTPort5BPDUGuardLocalread-writecurrentNID Series card STP CIST Port Configuration: CIST Normal Port5 Configuration - BPDU Guard 0: Non-edge 1: Edge
1.3.6.1.4.1.4756.20.500.20.1.1030ColumnnidCISTPort5PointToPointLocalread-writecurrentNID Series card STP CIST Port Configuration: CIST Normal Port5 Configuration - Point-to-point 0: Forced True 1: Forced False 2: Auto
1.3.6.1.4.1.4756.20.500.20.1.1031ColumnnidCISTPort6STPEnabledLocalread-writecurrentNID Series card STP CIST Port Configuration: CIST Normal Port6 Configuration - STP Enabled
1.3.6.1.4.1.4756.20.500.20.1.1032ColumnnidCISTPort6PathCostLocalread-writecurrentNID Series card STP CIST Port Configuration: CIST Normal Port6 Configuration - Path Cost Valid values are in the range 0 to 200000000. Setting 0 means Auto pat…
1.3.6.1.4.1.4756.20.500.20.1.1033ColumnnidCISTPort6PriorityLocalread-writecurrentNID Series card STP CIST Port Configuration: CIST Normal Port6 Configuration - Priority
1.3.6.1.4.1.4756.20.500.20.1.1034ColumnnidCISTPort6AdminEdgeLocalread-writecurrentNID Series card STP CIST Port Configuration: CIST Normal Port6 Configuration - STP Enabled 0: Non-edge 1: Edge
1.3.6.1.4.1.4756.20.500.20.1.1035ColumnnidCISTPort6AutoEdgeLocalread-writecurrentNID Series card STP CIST Port Configuration: CIST Normal Port6 Configuration - Auto Edge 0: Non-edge 1: Edge
1.3.6.1.4.1.4756.20.500.20.1.1036ColumnnidCISTPort6RestrictedRoleLocalread-writecurrentNID Series card STP CIST Port Configuration: CIST Normal Port6 Configuration - Restricted Role 0: Non-edge 1: Edge
1.3.6.1.4.1.4756.20.500.20.1.1037ColumnnidCISTPort6RestrictedTCNLocalread-writecurrentNID Series card STP CIST Port Configuration: CIST Normal Port6 Configuration - Restricted TCN 0: Non-edge 1: Edge
1.3.6.1.4.1.4756.20.500.20.1.1038ColumnnidCISTPort6BPDUGuardLocalread-writecurrentNID Series card STP CIST Port Configuration: CIST Normal Port6 Configuration - BPDU Guard 0: Non-edge 1: Edge
1.3.6.1.4.1.4756.20.500.20.1.1039ColumnnidCISTPort6PointToPointLocalread-writecurrentNID Series card STP CIST Port Configuration: CIST Normal Port6 Configuration - Point-to-point 0: Forced True 1: Forced False 2: Auto
1.3.6.1.4.1.4756.20.500.20.1.1040ColumnnidCISTPort7STPEnabledLocalread-writecurrentNID Series card STP CIST Port Configuration: CIST Normal Port7 Configuration - STP Enabled
1.3.6.1.4.1.4756.20.500.20.1.1041ColumnnidCISTPort7PathCostLocalread-writecurrentNID Series card STP CIST Port Configuration: CIST Normal Port7 Configuration - Path Cost Valid values are in the range 0 to 200000000. Setting 0 means Auto pat…
1.3.6.1.4.1.4756.20.500.20.1.1042ColumnnidCISTPort7PriorityLocalread-writecurrentNID Series card STP CIST Port Configuration: CIST Normal Port7 Configuration - Priority
1.3.6.1.4.1.4756.20.500.20.1.1043ColumnnidCISTPort7AdminEdgeLocalread-writecurrentNID Series card STP CIST Port Configuration: CIST Normal Port7 Configuration - STP Enabled 0: Non-edge 1: Edge
1.3.6.1.4.1.4756.20.500.20.1.1044ColumnnidCISTPort7AutoEdgeLocalread-writecurrentNID Series card STP CIST Port Configuration: CIST Normal Port7 Configuration - Auto Edge 0: Non-edge 1: Edge
1.3.6.1.4.1.4756.20.500.20.1.1045ColumnnidCISTPort7RestrictedRoleLocalread-writecurrentNID Series card STP CIST Port Configuration: CIST Normal Port7 Configuration - Restricted Role 0: Non-edge 1: Edge
1.3.6.1.4.1.4756.20.500.20.1.1046ColumnnidCISTPort7RestrictedTCNLocalread-writecurrentNID Series card STP CIST Port Configuration: CIST Normal Port7 Configuration - Restricted TCN 0: Non-edge 1: Edge
1.3.6.1.4.1.4756.20.500.20.1.1047ColumnnidCISTPort7BPDUGuardLocalread-writecurrentNID Series card STP CIST Port Configuration: CIST Normal Port7 Configuration - BPDU Guard 0: Non-edge 1: Edge
1.3.6.1.4.1.4756.20.500.20.1.1048ColumnnidCISTPort7PointToPointLocalread-writecurrentNID Series card STP CIST Port Configuration: CIST Normal Port7 Configuration - Point-to-point 0: Forced True 1: Forced False 2: Auto
1.3.6.1.4.1.4756.20.500.20.1.1049ColumnnidCISTPort8STPEnabledLocalread-writecurrentNID Series card STP CIST Port Configuration: CIST Normal Port8 Configuration - STP Enabled
1.3.6.1.4.1.4756.20.500.20.1.1050ColumnnidCISTPort8PathCostLocalread-writecurrentNID Series card STP CIST Port Configuration: CIST Normal Port8 Configuration - Path Cost Valid values are in the range 0 to 200000000. Setting 0 means Auto pat…
1.3.6.1.4.1.4756.20.500.20.1.1051ColumnnidCISTPort8PriorityLocalread-writecurrentNID Series card STP CIST Port Configuration: CIST Normal Port8 Configuration - Priority
1.3.6.1.4.1.4756.20.500.20.1.1052ColumnnidCISTPort8AdminEdgeLocalread-writecurrentNID Series card STP CIST Port Configuration: CIST Normal Port8 Configuration - STP Enabled 0: Non-edge 1: Edge
1.3.6.1.4.1.4756.20.500.20.1.1053ColumnnidCISTPort8AutoEdgeLocalread-writecurrentNID Series card STP CIST Port Configuration: CIST Normal Port8 Configuration - Auto Edge 0: Non-edge 1: Edge
1.3.6.1.4.1.4756.20.500.20.1.1054ColumnnidCISTPort8RestrictedRoleLocalread-writecurrentNID Series card STP CIST Port Configuration: CIST Normal Port8 Configuration - Restricted Role 0: Non-edge 1: Edge
1.3.6.1.4.1.4756.20.500.20.1.1055ColumnnidCISTPort8RestrictedTCNLocalread-writecurrentNID Series card STP CIST Port Configuration: CIST Normal Port8 Configuration - Restricted TCN 0: Non-edge 1: Edge
1.3.6.1.4.1.4756.20.500.20.1.1056ColumnnidCISTPort8BPDUGuardLocalread-writecurrentNID Series card STP CIST Port Configuration: CIST Normal Port8 Configuration - BPDU Guard 0: Non-edge 1: Edge
1.3.6.1.4.1.4756.20.500.20.1.1057ColumnnidCISTPort8PointToPointLocalread-writecurrentNID Series card STP CIST Port Configuration: CIST Normal Port8 Configuration - Point-to-point 0: Forced True 1: Forced False 2: Auto
1.3.6.1.4.1.4756.20.500.20.1.1058ColumnnidMSTI1AggregatedPathCostLocalread-writecurrentNID Series card MSTI Port Configuration: MSTI1 Aggregated Ports Configuration - Path Cost Valid values are in the range 0 to 200000000. Setting 0 means Auto pa…
1.3.6.1.4.1.4756.20.500.20.1.1059ColumnnidMSTI1AggregatedPriorityLocalread-writecurrentNID Series card MSTI Port Configuration: MSTI1 Aggregated Ports Configuration - Priority
1.3.6.1.4.1.4756.20.500.20.1.1060ColumnnidMSTI1Port1PathCostLocalread-writecurrentNID Series card MSTI Port Configuration: MSTI1 Normal Port1 Configuration - Path Cost Valid values are in the range 0 to 200000000. Setting 0 means Auto path c…
1.3.6.1.4.1.4756.20.500.20.1.1061ColumnnidMSTI1Port1PriorityLocalread-writecurrentNID Series card MSTI Port Configuration: MSTI1 Normal Port1 Configuration - Priority
1.3.6.1.4.1.4756.20.500.20.1.1062ColumnnidMSTI1Port2PathCostLocalread-writecurrentNID Series card MSTI Port Configuration: MSTI1 Normal Port2 Configuration - Path Cost Valid values are in the range 0 to 200000000. Setting 0 means Auto path c…
1.3.6.1.4.1.4756.20.500.20.1.1063ColumnnidMSTI1Port2PriorityLocalread-writecurrentNID Series card MSTI Port Configuration: MSTI1 Normal Port2 Configuration - Priority
1.3.6.1.4.1.4756.20.500.20.1.1064ColumnnidMSTI1Port3PathCostLocalread-writecurrentNID Series card MSTI Port Configuration: MSTI1 Normal Port3 Configuration - Path Cost Valid values are in the range 0 to 200000000. Setting 0 means Auto path c…
1.3.6.1.4.1.4756.20.500.20.1.1065ColumnnidMSTI1Port3PriorityLocalread-writecurrentNID Series card MSTI Port Configuration: MSTI1 Normal Port3 Configuration - Priority
1.3.6.1.4.1.4756.20.500.20.1.1066ColumnnidMSTI1Port4PathCostLocalread-writecurrentNID Series card MSTI Port Configuration: MSTI1 Normal Port4 Configuration - Path Cost Valid values are in the range 0 to 200000000. Setting 0 means Auto path c…
1.3.6.1.4.1.4756.20.500.20.1.1067ColumnnidMSTI1Port4PriorityLocalread-writecurrentNID Series card MSTI Port Configuration: MSTI1 Normal Port4 Configuration - Priority
1.3.6.1.4.1.4756.20.500.20.1.1068ColumnnidMSTI1Port5PathCostLocalread-writecurrentNID Series card MSTI Port Configuration: MSTI1 Normal Port5 Configuration - Path Cost Valid values are in the range 0 to 200000000. Setting 0 means Auto path c…
1.3.6.1.4.1.4756.20.500.20.1.1069ColumnnidMSTI1Port5PriorityLocalread-writecurrentNID Series card MSTI Port Configuration: MSTI1 Normal Port5 Configuration - Priority
1.3.6.1.4.1.4756.20.500.20.1.1070ColumnnidMSTI1Port6PathCostLocalread-writecurrentNID Series card MSTI Port Configuration: MSTI1 Normal Port6 Configuration - Path Cost Valid values are in the range 0 to 200000000. Setting 0 means Auto path c…
1.3.6.1.4.1.4756.20.500.20.1.1071ColumnnidMSTI1Port6PriorityLocalread-writecurrentNID Series card MSTI Port Configuration: MSTI1 Normal Port6 Configuration - Priority
1.3.6.1.4.1.4756.20.500.20.1.1072ColumnnidMSTI1Port7PathCostLocalread-writecurrentNID Series card MSTI Port Configuration: MSTI1 Normal Port7 Configuration - Path Cost Valid values are in the range 0 to 200000000. Setting 0 means Auto path c…
1.3.6.1.4.1.4756.20.500.20.1.1073ColumnnidMSTI1Port7PriorityLocalread-writecurrentNID Series card MSTI Port Configuration: MSTI1 Normal Port7 Configuration - Priority
1.3.6.1.4.1.4756.20.500.20.1.1074ColumnnidMSTI1Port8PathCostLocalread-writecurrentNID Series card MSTI Port Configuration: MSTI1 Normal Port8 Configuration - Path Cost Valid values are in the range 0 to 200000000. Setting 0 means Auto path c…
1.3.6.1.4.1.4756.20.500.20.1.1075ColumnnidMSTI1Port8PriorityLocalread-writecurrentNID Series card MSTI Port Configuration: MSTI1 Normal Port8 Configuration - Priority
1.3.6.1.4.1.4756.20.500.20.1.1076ColumnnidMSTI2AggregatedPathCostLocalread-writecurrentNID Series card MSTI Port Configuration: MSTI2 Aggregated Ports Configuration - Path Cost Valid values are in the range 0 to 200000000. Setting 0 means Auto pa…
1.3.6.1.4.1.4756.20.500.20.1.1077ColumnnidMSTI2AggregatedPriorityLocalread-writecurrentNID Series card MSTI Port Configuration: MSTI2 Aggregated Ports Configuration - Priority
1.3.6.1.4.1.4756.20.500.20.1.1078ColumnnidMSTI2Port1PathCostLocalread-writecurrentNID Series card MSTI Port Configuration: MSTI2 Normal Port1 Configuration - Path Cost Valid values are in the range 0 to 200000000. Setting 0 means Auto path c…
1.3.6.1.4.1.4756.20.500.20.1.1079ColumnnidMSTI2Port1PriorityLocalread-writecurrentNID Series card MSTI Port Configuration: MSTI2 Normal Port1 Configuration - Priority
1.3.6.1.4.1.4756.20.500.20.1.1080ColumnnidMSTI2Port2PathCostLocalread-writecurrentNID Series card MSTI Port Configuration: MSTI2 Normal Port2 Configuration - Path Cost Valid values are in the range 0 to 200000000. Setting 0 means Auto path c…
1.3.6.1.4.1.4756.20.500.20.1.1081ColumnnidMSTI2Port2PriorityLocalread-writecurrentNID Series card MSTI Port Configuration: MSTI2 Normal Port2 Configuration - Priority
1.3.6.1.4.1.4756.20.500.20.1.1082ColumnnidMSTI2Port3PathCostLocalread-writecurrentNID Series card MSTI Port Configuration: MSTI2 Normal Port3 Configuration - Path Cost Valid values are in the range 0 to 200000000. Setting 0 means Auto path c…
1.3.6.1.4.1.4756.20.500.20.1.1083ColumnnidMSTI2Port3PriorityLocalread-writecurrentNID Series card MSTI Port Configuration: MSTI2 Normal Port3 Configuration - Priority
1.3.6.1.4.1.4756.20.500.20.1.1084ColumnnidMSTI2Port4PathCostLocalread-writecurrentNID Series card MSTI Port Configuration: MSTI2 Normal Port4 Configuration - Path Cost Valid values are in the range 0 to 200000000. Setting 0 means Auto path c…
1.3.6.1.4.1.4756.20.500.20.1.1085ColumnnidMSTI2Port4PriorityLocalread-writecurrentNID Series card MSTI Port Configuration: MSTI2 Normal Port4 Configuration - Priority
1.3.6.1.4.1.4756.20.500.20.1.1086ColumnnidMSTI2Port5PathCostLocalread-writecurrentNID Series card MSTI Port Configuration: MSTI2 Normal Port5 Configuration - Path Cost Valid values are in the range 0 to 200000000. Setting 0 means Auto path c…
1.3.6.1.4.1.4756.20.500.20.1.1087ColumnnidMSTI2Port5PriorityLocalread-writecurrentNID Series card MSTI Port Configuration: MSTI2 Normal Port5 Configuration - Priority
1.3.6.1.4.1.4756.20.500.20.1.1088ColumnnidMSTI2Port6PathCostLocalread-writecurrentNID Series card MSTI Port Configuration: MSTI2 Normal Port6 Configuration - Path Cost Valid values are in the range 0 to 200000000. Setting 0 means Auto path c…
1.3.6.1.4.1.4756.20.500.20.1.1089ColumnnidMSTI2Port6PriorityLocalread-writecurrentNID Series card MSTI Port Configuration: MSTI2 Normal Port6 Configuration - Priority
1.3.6.1.4.1.4756.20.500.20.1.1090ColumnnidMSTI2Port7PathCostLocalread-writecurrentNID Series card MSTI Port Configuration: MSTI2 Normal Port7 Configuration - Path Cost Valid values are in the range 0 to 200000000. Setting 0 means Auto path c…
1.3.6.1.4.1.4756.20.500.20.1.1091ColumnnidMSTI2Port7PriorityLocalread-writecurrentNID Series card MSTI Port Configuration: MSTI2 Normal Port7 Configuration - Priority
1.3.6.1.4.1.4756.20.500.20.1.1092ColumnnidMSTI2Port8PathCostLocalread-writecurrentNID Series card MSTI Port Configuration: MSTI2 Normal Port8 Configuration - Path Cost Valid values are in the range 0 to 200000000. Setting 0 means Auto path c…
1.3.6.1.4.1.4756.20.500.20.1.1093ColumnnidMSTI2Port8PriorityLocalread-writecurrentNID Series card MSTI Port Configuration: MSTI2 Normal Port8 Configuration - Priority
1.3.6.1.4.1.4756.20.500.20.1.1094ColumnnidMSTI3AggregatedPathCostLocalread-writecurrentNID Series card MSTI Port Configuration: MSTI3 Aggregated Ports Configuration - Path Cost Valid values are in the range 0 to 200000000. Setting 0 means Auto pa…
1.3.6.1.4.1.4756.20.500.20.1.1095ColumnnidMSTI3AggregatedPriorityLocalread-writecurrentNID Series card MSTI Port Configuration: MSTI3 Aggregated Ports Configuration - Priority
1.3.6.1.4.1.4756.20.500.20.1.1096ColumnnidMSTI3Port1PathCostLocalread-writecurrentNID Series card MSTI Port Configuration: MSTI3 Normal Port1 Configuration - Path Cost Valid values are in the range 0 to 200000000. Setting 0 means Auto path c…
1.3.6.1.4.1.4756.20.500.20.1.1097ColumnnidMSTI3Port1PriorityLocalread-writecurrentNID Series card MSTI Port Configuration: MSTI3 Normal Port1 Configuration - Priority
1.3.6.1.4.1.4756.20.500.20.1.1098ColumnnidMSTI3Port2PathCostLocalread-writecurrentNID Series card MSTI Port Configuration: MSTI3 Normal Port2 Configuration - Path Cost Valid values are in the range 0 to 200000000. Setting 0 means Auto path c…
1.3.6.1.4.1.4756.20.500.20.1.1099ColumnnidMSTI3Port2PriorityLocalread-writecurrentNID Series card MSTI Port Configuration: MSTI3 Normal Port2 Configuration - Priority
1.3.6.1.4.1.4756.20.500.20.1.1100ColumnnidMSTI3Port3PathCostLocalread-writecurrentNID Series card MSTI Port Configuration: MSTI1 Normal Port3 Configuration - Path Cost Valid values are in the range 0 to 200000000. Setting 0 means Auto path c…
1.3.6.1.4.1.4756.20.500.20.1.1101ColumnnidMSTI3Port3PriorityLocalread-writecurrentNID Series card MSTI Port Configuration: MSTI3 Normal Port3 Configuration - Priority
1.3.6.1.4.1.4756.20.500.20.1.1102ColumnnidMSTI3Port4PathCostLocalread-writecurrentNID Series card MSTI Port Configuration: MSTI3 Normal Port4 Configuration - Path Cost Valid values are in the range 0 to 200000000. Setting 0 means Auto path c…
1.3.6.1.4.1.4756.20.500.20.1.1103ColumnnidMSTI3Port4PriorityLocalread-writecurrentNID Series card MSTI Port Configuration: MSTI3 Normal Port4 Configuration - Priority
1.3.6.1.4.1.4756.20.500.20.1.1104ColumnnidMSTI3Port5PathCostLocalread-writecurrentNID Series card MSTI Port Configuration: MSTI3 Normal Port5 Configuration - Path Cost Valid values are in the range 0 to 200000000. Setting 0 means Auto path c…
1.3.6.1.4.1.4756.20.500.20.1.1105ColumnnidMSTI3Port5PriorityLocalread-writecurrentNID Series card MSTI Port Configuration: MSTI3 Normal Port5 Configuration - Priority
1.3.6.1.4.1.4756.20.500.20.1.1106ColumnnidMSTI3Port6PathCostLocalread-writecurrentNID Series card MSTI Port Configuration: MSTI3 Normal Port6 Configuration - Path Cost Valid values are in the range 0 to 200000000. Setting 0 means Auto path c…
1.3.6.1.4.1.4756.20.500.20.1.1107ColumnnidMSTI3Port6PriorityLocalread-writecurrentNID Series card MSTI Port Configuration: MSTI3 Normal Port6 Configuration - Priority
1.3.6.1.4.1.4756.20.500.20.1.1108ColumnnidMSTI3Port7PathCostLocalread-writecurrentNID Series card MSTI Port Configuration: MSTI3 Normal Port7 Configuration - Path Cost Valid values are in the range 0 to 200000000. Setting 0 means Auto path c…
1.3.6.1.4.1.4756.20.500.20.1.1109ColumnnidMSTI3Port7PriorityLocalread-writecurrentNID Series card MSTI Port Configuration: MSTI3 Normal Port7 Configuration - Priority
1.3.6.1.4.1.4756.20.500.20.1.1110ColumnnidMSTI3Port8PathCostLocalread-writecurrentNID Series card MSTI Port Configuration: MSTI3 Normal Port8 Configuration - Path Cost Valid values are in the range 0 to 200000000. Setting 0 means Auto path c…
1.3.6.1.4.1.4756.20.500.20.1.1111ColumnnidMSTI3Port8PriorityLocalread-writecurrentNID Series card MSTI Port Configuration: MSTI3 Normal Port8 Configuration - Priority
1.3.6.1.4.1.4756.20.500.20.1.1112ColumnnidMSTI4AggregatedPathCostLocalread-writecurrentNID Series card MSTI Port Configuration: MSTI4 Aggregated Ports Configuration - Path Cost Valid values are in the range 0 to 200000000. Setting 0 means Auto pa…
1.3.6.1.4.1.4756.20.500.20.1.1113ColumnnidMSTI4AggregatedPriorityLocalread-writecurrentNID Series card MSTI Port Configuration: MSTI4 Aggregated Ports Configuration - Priority
1.3.6.1.4.1.4756.20.500.20.1.1114ColumnnidMSTI4Port1PathCostLocalread-writecurrentNID Series card MSTI Port Configuration: MSTI4 Normal Port1 Configuration - Path Cost Valid values are in the range 0 to 200000000. Setting 0 means Auto path c…
1.3.6.1.4.1.4756.20.500.20.1.1115ColumnnidMSTI4Port1PriorityLocalread-writecurrentNID Series card MSTI Port Configuration: MSTI4 Normal Port1 Configuration - Priority
1.3.6.1.4.1.4756.20.500.20.1.1116ColumnnidMSTI4Port2PathCostLocalread-writecurrentNID Series card MSTI Port Configuration: MSTI4 Normal Port2 Configuration - Path Cost Valid values are in the range 0 to 200000000. Setting 0 means Auto path c…
1.3.6.1.4.1.4756.20.500.20.1.1117ColumnnidMSTI4Port2PriorityLocalread-writecurrentNID Series card MSTI Port Configuration: MSTI4 Normal Port2 Configuration - Priority
1.3.6.1.4.1.4756.20.500.20.1.1118ColumnnidMSTI4Port3PathCostLocalread-writecurrentNID Series card MSTI Port Configuration: MSTI1 Normal Port3 Configuration - Path Cost Valid values are in the range 0 to 200000000. Setting 0 means Auto path c…
1.3.6.1.4.1.4756.20.500.20.1.1119ColumnnidMSTI4Port3PriorityLocalread-writecurrentNID Series card MSTI Port Configuration: MSTI4 Normal Port3 Configuration - Priority
1.3.6.1.4.1.4756.20.500.20.1.1120ColumnnidMSTI4Port4PathCostLocalread-writecurrentNID Series card MSTI Port Configuration: MSTI4 Normal Port4 Configuration - Path Cost Valid values are in the range 0 to 200000000. Setting 0 means Auto path c…
1.3.6.1.4.1.4756.20.500.20.1.1121ColumnnidMSTI4Port4PriorityLocalread-writecurrentNID Series card MSTI Port Configuration: MSTI4 Normal Port4 Configuration - Priority
1.3.6.1.4.1.4756.20.500.20.1.1122ColumnnidMSTI4Port5PathCostLocalread-writecurrentNID Series card MSTI Port Configuration: MSTI4 Normal Port5 Configuration - Path Cost Valid values are in the range 0 to 200000000. Setting 0 means Auto path c…
1.3.6.1.4.1.4756.20.500.20.1.1123ColumnnidMSTI4Port5PriorityLocalread-writecurrentNID Series card MSTI Port Configuration: MSTI4 Normal Port5 Configuration - Priority
1.3.6.1.4.1.4756.20.500.20.1.1124ColumnnidMSTI4Port6PathCostLocalread-writecurrentNID Series card MSTI Port Configuration: MSTI4 Normal Port4 Configuration - Path Cost Valid values are in the range 0 to 200000000. Setting 0 means Auto path c…
1.3.6.1.4.1.4756.20.500.20.1.1125ColumnnidMSTI4Port6PriorityLocalread-writecurrentNID Series card MSTI Port Configuration: MSTI4 Normal Port6 Configuration - Priority
1.3.6.1.4.1.4756.20.500.20.1.1126ColumnnidMSTI4Port7PathCostLocalread-writecurrentNID Series card MSTI Port Configuration: MSTI4 Normal Port7 Configuration - Path Cost Valid values are in the range 0 to 200000000. Setting 0 means Auto path c…
1.3.6.1.4.1.4756.20.500.20.1.1127ColumnnidMSTI4Port7PriorityLocalread-writecurrentNID Series card MSTI Port Configuration: MSTI4 Normal Port7 Configuration - Priority
1.3.6.1.4.1.4756.20.500.20.1.1128ColumnnidMSTI4Port8PathCostLocalread-writecurrentNID Series card MSTI Port Configuration: MSTI4 Normal Port8 Configuration - Path Cost Valid values are in the range 0 to 200000000. Setting 0 means Auto path c…
1.3.6.1.4.1.4756.20.500.20.1.1129ColumnnidMSTI4Port8PriorityLocalread-writecurrentNID Series card MSTI Port Configuration: MSTI4 Normal Port8 Configuration - Priority
1.3.6.1.4.1.4756.20.500.20.1.1130ColumnnidMSTI5AggregatedPathCostLocalread-writecurrentNID Series card MSTI Port Configuration: MSTI5 Aggregated Ports Configuration - Path Cost Valid values are in the range 0 to 200000000. Setting 0 means Auto pa…
1.3.6.1.4.1.4756.20.500.20.1.1131ColumnnidMSTI5AggregatedPriorityLocalread-writecurrentNID Series card MSTI Port Configuration: MSTI5 Aggregated Ports Configuration - Priority
1.3.6.1.4.1.4756.20.500.20.1.1132ColumnnidMSTI5Port1PathCostLocalread-writecurrentNID Series card MSTI Port Configuration: MSTI5 Normal Port1 Configuration - Path Cost Valid values are in the range 0 to 200000000. Setting 0 means Auto path c…
1.3.6.1.4.1.4756.20.500.20.1.1133ColumnnidMSTI5Port1PriorityLocalread-writecurrentNID Series card MSTI Port Configuration: MSTI5 Normal Port1 Configuration - Priority
1.3.6.1.4.1.4756.20.500.20.1.1134ColumnnidMSTI5Port2PathCostLocalread-writecurrentNID Series card MSTI Port Configuration: MSTI5 Normal Port2 Configuration - Path Cost Valid values are in the range 0 to 200000000. Setting 0 means Auto path c…
1.3.6.1.4.1.4756.20.500.20.1.1135ColumnnidMSTI5Port2PriorityLocalread-writecurrentNID Series card MSTI Port Configuration: MSTI5 Normal Port2 Configuration - Priority
1.3.6.1.4.1.4756.20.500.20.1.1136ColumnnidMSTI5Port3PathCostLocalread-writecurrentNID Series card MSTI Port Configuration: MSTI5 Normal Port3 Configuration - Path Cost Valid values are in the range 0 to 200000000. Setting 0 means Auto path c…
1.3.6.1.4.1.4756.20.500.20.1.1137ColumnnidMSTI5Port3PriorityLocalread-writecurrentNID Series card MSTI Port Configuration: MSTI5 Normal Port3 Configuration - Priority
1.3.6.1.4.1.4756.20.500.20.1.1138ColumnnidMSTI5Port4PathCostLocalread-writecurrentNID Series card MSTI Port Configuration: MSTI5 Normal Port4 Configuration - Path Cost Valid values are in the range 0 to 200000000. Setting 0 means Auto path c…
1.3.6.1.4.1.4756.20.500.20.1.1139ColumnnidMSTI5Port4PriorityLocalread-writecurrentNID Series card MSTI Port Configuration: MSTI5 Normal Port4 Configuration - Priority
1.3.6.1.4.1.4756.20.500.20.1.1140ColumnnidMSTI5Port5PathCostLocalread-writecurrentNID Series card MSTI Port Configuration: MSTI5 Normal Port5 Configuration - Path Cost Valid values are in the range 0 to 200000000. Setting 0 means Auto path c…
1.3.6.1.4.1.4756.20.500.20.1.1141ColumnnidMSTI5Port5PriorityLocalread-writecurrentNID Series card MSTI Port Configuration: MSTI5 Normal Port5 Configuration - Priority
1.3.6.1.4.1.4756.20.500.20.1.1142ColumnnidMSTI5Port6PathCostLocalread-writecurrentNID Series card MSTI Port Configuration: MSTI5 Normal Port6 Configuration - Path Cost Valid values are in the range 0 to 200000000. Setting 0 means Auto path c…
1.3.6.1.4.1.4756.20.500.20.1.1143ColumnnidMSTI5Port6PriorityLocalread-writecurrentNID Series card MSTI Port Configuration: MSTI5 Normal Port6 Configuration - Priority
1.3.6.1.4.1.4756.20.500.20.1.1144ColumnnidMSTI5Port7PathCostLocalread-writecurrentNID Series card MSTI Port Configuration: MSTI5 Normal Port7 Configuration - Path Cost Valid values are in the range 0 to 200000000. Setting 0 means Auto path c…
1.3.6.1.4.1.4756.20.500.20.1.1145ColumnnidMSTI5Port7PriorityLocalread-writecurrentNID Series card MSTI Port Configuration: MSTI5 Normal Port7 Configuration - Priority
1.3.6.1.4.1.4756.20.500.20.1.1146ColumnnidMSTI5Port8PathCostLocalread-writecurrentNID Series card MSTI Port Configuration: MSTI5 Normal Port8 Configuration - Path Cost Valid values are in the range 0 to 200000000. Setting 0 means Auto path c…
1.3.6.1.4.1.4756.20.500.20.1.1147ColumnnidMSTI5Port8PriorityLocalread-writecurrentNID Series card MSTI Port Configuration: MSTI5 Normal Port8 Configuration - Priority
1.3.6.1.4.1.4756.20.500.20.1.1148ColumnnidMSTI6AggregatedPathCostLocalread-writecurrentNID Series card MSTI Port Configuration: MSTI6 Aggregated Ports Configuration - Path Cost Valid values are in the range 0 to 200000000. Setting 0 means Auto pa…
1.3.6.1.4.1.4756.20.500.20.1.1149ColumnnidMSTI6AggregatedPriorityLocalread-writecurrentNID Series card MSTI Port Configuration: MSTI6 Aggregated Ports Configuration - Priority
1.3.6.1.4.1.4756.20.500.20.1.1150ColumnnidMSTI6Port1PathCostLocalread-writecurrentNID Series card MSTI Port Configuration: MSTI6 Normal Port1 Configuration - Path Cost Valid values are in the range 0 to 200000000. Setting 0 means Auto path c…
1.3.6.1.4.1.4756.20.500.20.1.1151ColumnnidMSTI6Port1PriorityLocalread-writecurrentNID Series card MSTI Port Configuration: MSTI6 Normal Port1 Configuration - Priority
1.3.6.1.4.1.4756.20.500.20.1.1152ColumnnidMSTI6Port2PathCostLocalread-writecurrentNID Series card MSTI Port Configuration: MSTI6 Normal Port2 Configuration - Path Cost Valid values are in the range 0 to 200000000. Setting 0 means Auto path c…
1.3.6.1.4.1.4756.20.500.20.1.1153ColumnnidMSTI6Port2PriorityLocalread-writecurrentNID Series card MSTI Port Configuration: MSTI6 Normal Port2 Configuration - Priority
1.3.6.1.4.1.4756.20.500.20.1.1154ColumnnidMSTI6Port3PathCostLocalread-writecurrentNID Series card MSTI Port Configuration: MSTI6 Normal Port3 Configuration - Path Cost Valid values are in the range 0 to 200000000. Setting 0 means Auto path c…
1.3.6.1.4.1.4756.20.500.20.1.1155ColumnnidMSTI6Port3PriorityLocalread-writecurrentNID Series card MSTI Port Configuration: MSTI6 Normal Port3 Configuration - Priority
1.3.6.1.4.1.4756.20.500.20.1.1156ColumnnidMSTI6Port4PathCostLocalread-writecurrentNID Series card MSTI Port Configuration: MSTI6 Normal Port4 Configuration - Path Cost Valid values are in the range 0 to 200000000. Setting 0 means Auto path c…
1.3.6.1.4.1.4756.20.500.20.1.1157ColumnnidMSTI6Port4PriorityLocalread-writecurrentNID Series card MSTI Port Configuration: MSTI6 Normal Port4 Configuration - Priority
1.3.6.1.4.1.4756.20.500.20.1.1158ColumnnidMSTI6Port5PathCostLocalread-writecurrentNID Series card MSTI Port Configuration: MSTI6 Normal Port5 Configuration - Path Cost Valid values are in the range 0 to 200000000. Setting 0 means Auto path c…
1.3.6.1.4.1.4756.20.500.20.1.1159ColumnnidMSTI6Port5PriorityLocalread-writecurrentNID Series card MSTI Port Configuration: MSTI6 Normal Port6 Configuration - Priority
1.3.6.1.4.1.4756.20.500.20.1.1160ColumnnidMSTI6Port6PathCostLocalread-writecurrentNID Series card MSTI Port Configuration: MSTI6 Normal Port6 Configuration - Path Cost Valid values are in the range 0 to 200000000. Setting 0 means Auto path c…
1.3.6.1.4.1.4756.20.500.20.1.1161ColumnnidMSTI6Port6PriorityLocalread-writecurrentNID Series card MSTI Port Configuration: MSTI6 Normal Port6 Configuration - Priority
1.3.6.1.4.1.4756.20.500.20.1.1162ColumnnidMSTI6Port7PathCostLocalread-writecurrentNID Series card MSTI Port Configuration: MSTI6 Normal Port7 Configuration - Path Cost Valid values are in the range 0 to 200000000. Setting 0 means Auto path c…
1.3.6.1.4.1.4756.20.500.20.1.1163ColumnnidMSTI6Port7PriorityLocalread-writecurrentNID Series card MSTI Port Configuration: MSTI6 Normal Port6 Configuration - Priority
1.3.6.1.4.1.4756.20.500.20.1.1164ColumnnidMSTI6Port8PathCostLocalread-writecurrentNID Series card MSTI Port Configuration: MSTI6 Normal Port8 Configuration - Path Cost Valid values are in the range 0 to 200000000. Setting 0 means Auto path c…
1.3.6.1.4.1.4756.20.500.20.1.1165ColumnnidMSTI6Port8PriorityLocalread-writecurrentNID Series card MSTI Port Configuration: MSTI6 Normal Port8 Configuration - Priority
1.3.6.1.4.1.4756.20.500.20.1.1166ColumnnidMSTI7AggregatedPathCostLocalread-writecurrentNID Series card MSTI Port Configuration: MSTI7 Aggregated Ports Configuration - Path Cost Valid values are in the range 0 to 200000000. Setting 0 means Auto pa…
1.3.6.1.4.1.4756.20.500.20.1.1167ColumnnidMSTI7AggregatedPriorityLocalread-writecurrentNID Series card MSTI Port Configuration: MSTI7 Aggregated Ports Configuration - Priority
1.3.6.1.4.1.4756.20.500.20.1.1168ColumnnidMSTI7Port1PathCostLocalread-writecurrentNID Series card MSTI Port Configuration: MSTI1 Normal Port1 Configuration - Path Cost Valid values are in the range 0 to 200000000. Setting 0 means Auto path c…
1.3.6.1.4.1.4756.20.500.20.1.1169ColumnnidMSTI7Port1PriorityLocalread-writecurrentNID Series card MSTI Port Configuration: MSTI1 Normal Port1 Configuration - Priority
1.3.6.1.4.1.4756.20.500.20.1.1170ColumnnidMSTI7Port2PathCostLocalread-writecurrentNID Series card MSTI Port Configuration: MSTI7 Normal Port2 Configuration - Path Cost Valid values are in the range 0 to 200000000. Setting 0 means Auto path c…
1.3.6.1.4.1.4756.20.500.20.1.1171ColumnnidMSTI7Port2PriorityLocalread-writecurrentNID Series card MSTI Port Configuration: MSTI7 Normal Port2 Configuration - Priority
1.3.6.1.4.1.4756.20.500.20.1.1172ColumnnidMSTI7Port3PathCostLocalread-writecurrentNID Series card MSTI Port Configuration: MSTI7 Normal Port3 Configuration - Path Cost Valid values are in the range 0 to 200000000. Setting 0 means Auto path c…
1.3.6.1.4.1.4756.20.500.20.1.1173ColumnnidMSTI7Port3PriorityLocalread-writecurrentNID Series card MSTI Port Configuration: MSTI7 Normal Port3 Configuration - Priority
1.3.6.1.4.1.4756.20.500.20.1.1174ColumnnidMSTI7Port4PathCostLocalread-writecurrentNID Series card MSTI Port Configuration: MSTI7 Normal Port4 Configuration - Path Cost Valid values are in the range 0 to 200000000. Setting 0 means Auto path c…
1.3.6.1.4.1.4756.20.500.20.1.1175ColumnnidMSTI7Port4PriorityLocalread-writecurrentNID Series card MSTI Port Configuration: MSTI7 Normal Port4 Configuration - Priority
1.3.6.1.4.1.4756.20.500.20.1.1176ColumnnidMSTI7Port5PathCostLocalread-writecurrentNID Series card MSTI Port Configuration: MSTI7 Normal Port5 Configuration - Path Cost Valid values are in the range 0 to 200000000. Setting 0 means Auto path c…
1.3.6.1.4.1.4756.20.500.20.1.1177ColumnnidMSTI7Port5PriorityLocalread-writecurrentNID Series card MSTI Port Configuration: MSTI7 Normal Port5 Configuration - Priority
1.3.6.1.4.1.4756.20.500.20.1.1178ColumnnidMSTI7Port6PathCostLocalread-writecurrentNID Series card MSTI Port Configuration: MSTI7 Normal Port6 Configuration - Path Cost Valid values are in the range 0 to 200000000. Setting 0 means Auto path c…
1.3.6.1.4.1.4756.20.500.20.1.1179ColumnnidMSTI7Port6PriorityLocalread-writecurrentNID Series card MSTI Port Configuration: MSTI7 Normal Port6 Configuration - Priority
1.3.6.1.4.1.4756.20.500.20.1.1180ColumnnidMSTI7Port7PathCostLocalread-writecurrentNID Series card MSTI Port Configuration: MSTI7 Normal Port7 Configuration - Path Cost Valid values are in the range 0 to 200000000. Setting 0 means Auto path c…
1.3.6.1.4.1.4756.20.500.20.1.1181ColumnnidMSTI7Port7PriorityLocalread-writecurrentNID Series card MSTI Port Configuration: MSTI7 Normal Port7 Configuration - Priority
1.3.6.1.4.1.4756.20.500.20.1.1182ColumnnidMSTI7Port8PathCostLocalread-writecurrentNID Series card MSTI Port Configuration: MSTI7 Normal Port8 Configuration - Path Cost Valid values are in the range 0 to 200000000. Setting 0 means Auto path c…
1.3.6.1.4.1.4756.20.500.20.1.1183ColumnnidMSTI7Port8PriorityLocalread-writecurrentNID Series card MSTI Port Configuration: MSTI7 Normal Port8 Configuration - Priority
1.3.6.1.4.1.4756.20.500.20.1.1184ColumnnidMSTI8AggregatedPathCostLocalread-writecurrentNID Series card MSTI Port Configuration: MSTI8 Aggregated Ports Configuration - Path Cost Valid values are in the range 0 to 200000000. Setting 0 means Auto pa…
1.3.6.1.4.1.4756.20.500.20.1.1185ColumnnidMSTI8AggregatedPriorityLocalread-writecurrentNID Series card MSTI Port Configuration: MSTI7 Aggregated Ports Configuration - Priority
1.3.6.1.4.1.4756.20.500.20.1.1186ColumnnidMSTI8Port1PathCostLocalread-writecurrentNID Series card MSTI Port Configuration: MSTI8 Normal Port1 Configuration - Path Cost Valid values are in the range 0 to 200000000. Setting 0 means Auto path c…
1.3.6.1.4.1.4756.20.500.20.1.1187ColumnnidMSTI8Port1PriorityLocalread-writecurrentNID Series card MSTI Port Configuration: MSTI8 Normal Port1 Configuration - Priority
1.3.6.1.4.1.4756.20.500.20.1.1188ColumnnidMSTI8Port2PathCostLocalread-writecurrentNID Series card MSTI Port Configuration: MSTI8 Normal Port2 Configuration - Path Cost Valid values are in the range 0 to 200000000. Setting 0 means Auto path c…
1.3.6.1.4.1.4756.20.500.20.1.1189ColumnnidMSTI8Port2PriorityLocalread-writecurrentNID Series card MSTI Port Configuration: MSTI8 Normal Port2 Configuration - Priority
1.3.6.1.4.1.4756.20.500.20.1.1190ColumnnidMSTI8Port3PathCostLocalread-writecurrentNID Series card MSTI Port Configuration: MSTI8 Normal Port3 Configuration - Path Cost Valid values are in the range 0 to 200000000. Setting 0 means Auto path c…
1.3.6.1.4.1.4756.20.500.20.1.1191ColumnnidMSTI8Port3PriorityLocalread-writecurrentNID Series card MSTI Port Configuration: MSTI8 Normal Port3 Configuration - Priority
1.3.6.1.4.1.4756.20.500.20.1.1192ColumnnidMSTI8Port4PathCostLocalread-writecurrentNID Series card MSTI Port Configuration: MSTI8 Normal Port4 Configuration - Path Cost Valid values are in the range 0 to 200000000. Setting 0 means Auto path c…
1.3.6.1.4.1.4756.20.500.20.1.1193ColumnnidMSTI8Port4PriorityLocalread-writecurrentNID Series card MSTI Port Configuration: MSTI8 Normal Port4 Configuration - Priority
1.3.6.1.4.1.4756.20.500.20.1.1194ColumnnidMSTI8Port5PathCostLocalread-writecurrentNID Series card MSTI Port Configuration: MSTI8 Normal Port5 Configuration - Path Cost Valid values are in the range 0 to 200000000. Setting 0 means Auto path c…
1.3.6.1.4.1.4756.20.500.20.1.1195ColumnnidMSTI8Port5PriorityLocalread-writecurrentNID Series card MSTI Port Configuration: MSTI8 Normal Port5 Configuration - Priority
1.3.6.1.4.1.4756.20.500.20.1.1196ColumnnidMSTI8Port6PathCostLocalread-writecurrentNID Series card MSTI Port Configuration: MSTI8 Normal Port6 Configuration - Path Cost Valid values are in the range 0 to 200000000. Setting 0 means Auto path c…
1.3.6.1.4.1.4756.20.500.20.1.1197ColumnnidMSTI8Port6PriorityLocalread-writecurrentNID Series card MSTI Port Configuration: MSTI8 Normal Port6 Configuration - Priority
1.3.6.1.4.1.4756.20.500.20.1.1198ColumnnidMSTI8Port7PathCostLocalread-writecurrentNID Series card MSTI Port Configuration: MSTI8 Normal Port7 Configuration - Path Cost Valid values are in the range 0 to 200000000. Setting 0 means Auto path c…
1.3.6.1.4.1.4756.20.500.20.1.1199ColumnnidMSTI8Port7PriorityLocalread-writecurrentNID Series card MSTI Port Configuration: MSTI8 Normal Port7 Configuration - Priority
1.3.6.1.4.1.4756.20.500.20.1.1200ColumnnidMSTI8Port8PathCostLocalread-writecurrentNID Series card MSTI Port Configuration: MSTI7 Normal Port8 Configuration - Path Cost Valid values are in the range 0 to 200000000. Setting 0 means Auto path c…
1.3.6.1.4.1.4756.20.500.20.1.1201ColumnnidMSTI8Port8PriorityLocalread-writecurrentNID Series card MSTI Port Configuration: MSTI8 Normal Port8 Configuration - Priority
1.3.6.1.4.1.4756.20.500.20.1.1202ColumnnidMSTI9AggregatedPathCostLocalread-writecurrentNID Series card MSTI Port Configuration: MSTI9 Aggregated Ports Configuration - Path Cost Valid values are in the range 0 to 200000000. Setting 0 means Auto pa…
1.3.6.1.4.1.4756.20.500.20.1.1203ColumnnidMSTI9AggregatedPriorityLocalread-writecurrentNID Series card MSTI Port Configuration: MSTI9 Aggregated Ports Configuration - Priority
1.3.6.1.4.1.4756.20.500.20.1.1204ColumnnidMSTI9Port1PathCostLocalread-writecurrentNID Series card MSTI Port Configuration: MSTI9 Normal Port1 Configuration - Path Cost Valid values are in the range 0 to 200000000. Setting 0 means Auto path c…
1.3.6.1.4.1.4756.20.500.20.1.1205ColumnnidMSTI9Port1PriorityLocalread-writecurrentNID Series card MSTI Port Configuration: MSTI9 Normal Port1 Configuration - Priority
1.3.6.1.4.1.4756.20.500.20.1.1206ColumnnidMSTI9Port2PathCostLocalread-writecurrentNID Series card MSTI Port Configuration: MSTI9 Normal Port2 Configuration - Path Cost Valid values are in the range 0 to 200000000. Setting 0 means Auto path c…
1.3.6.1.4.1.4756.20.500.20.1.1207ColumnnidMSTI9Port2PriorityLocalread-writecurrentNID Series card MSTI Port Configuration: MSTI8 Normal Port2 Configuration - Priority
1.3.6.1.4.1.4756.20.500.20.1.1208ColumnnidMSTI9Port3PathCostLocalread-writecurrentNID Series card MSTI Port Configuration: MSTI8 Normal Port3 Configuration - Path Cost Valid values are in the range 0 to 200000000. Setting 0 means Auto path c…
1.3.6.1.4.1.4756.20.500.20.1.1209ColumnnidMSTI9Port3PriorityLocalread-writecurrentNID Series card MSTI Port Configuration: MSTI9 Normal Port3 Configuration - Priority
1.3.6.1.4.1.4756.20.500.20.1.1210ColumnnidMSTI9Port4PathCostLocalread-writecurrentNID Series card MSTI Port Configuration: MSTI9 Normal Port4 Configuration - Path Cost Valid values are in the range 0 to 200000000. Setting 0 means Auto path c…
1.3.6.1.4.1.4756.20.500.20.1.1211ColumnnidMSTI9Port4PriorityLocalread-writecurrentNID Series card MSTI Port Configuration: MSTI9 Normal Port4 Configuration - Priority
1.3.6.1.4.1.4756.20.500.20.1.1212ColumnnidMSTI9Port5PathCostLocalread-writecurrentNID Series card MSTI Port Configuration: MSTI9 Normal Port5 Configuration - Path Cost Valid values are in the range 0 to 200000000. Setting 0 means Auto path c…
1.3.6.1.4.1.4756.20.500.20.1.1213ColumnnidMSTI9Port5PriorityLocalread-writecurrentNID Series card MSTI Port Configuration: MSTI9 Normal Port5 Configuration - Priority
1.3.6.1.4.1.4756.20.500.20.1.1214ColumnnidMSTI9Port6PathCostLocalread-writecurrentNID Series card MSTI Port Configuration: MSTI9 Normal Port6 Configuration - Path Cost Valid values are in the range 0 to 200000000. Setting 0 means Auto path c…
1.3.6.1.4.1.4756.20.500.20.1.1215ColumnnidMSTI9Port6PriorityLocalread-writecurrentNID Series card MSTI Port Configuration: MSTI9 Normal Port6 Configuration - Priority
1.3.6.1.4.1.4756.20.500.20.1.1216ColumnnidMSTI9Port7PathCostLocalread-writecurrentNID Series card MSTI Port Configuration: MSTI9 Normal Port7 Configuration - Path Cost Valid values are in the range 0 to 200000000. Setting 0 means Auto path c…
1.3.6.1.4.1.4756.20.500.20.1.1217ColumnnidMSTI9Port7PriorityLocalread-writecurrentNID Series card MSTI Port Configuration: MSTI9 Normal Port7 Configuration - Priority
1.3.6.1.4.1.4756.20.500.20.1.1218ColumnnidMSTI9Port8PathCostLocalread-writecurrentNID Series card MSTI Port Configuration: MSTI8 Normal Port8 Configuration - Path Cost Valid values are in the range 0 to 200000000. Setting 0 means Auto path c…
1.3.6.1.4.1.4756.20.500.20.1.1219ColumnnidMSTI9Port8PriorityLocalread-writecurrentNID Series card MSTI Port Configuration: MSTI9 Normal Port8 Configuration - Priority
1.3.6.1.4.1.4756.20.500.20.1.1220ColumnnidMSTI10AggregatedPathCostLocalread-writecurrentNID Series card MSTI Port Configuration: MSTI10 Aggregated Ports Configuration - Path Cost Valid values are in the range 0 to 200000000. Setting 0 means Auto p…
1.3.6.1.4.1.4756.20.500.20.1.1221ColumnnidMSTI10AggregatedPriorityLocalread-writecurrentNID Series card MSTI Port Configuration: MSTI10 Aggregated Ports Configuration - Priority
1.3.6.1.4.1.4756.20.500.20.1.1222ColumnnidMSTI10Port1PathCostLocalread-writecurrentNID Series card MSTI Port Configuration: MSTI10 Normal Port1 Configuration - Path Cost Valid values are in the range 0 to 200000000. Setting 0 means Auto path …
1.3.6.1.4.1.4756.20.500.20.1.1223ColumnnidMSTI10Port1PriorityLocalread-writecurrentNID Series card MSTI Port Configuration: MSTI10 Normal Port1 Configuration - Priority
1.3.6.1.4.1.4756.20.500.20.1.1224ColumnnidMSTI10Port2PathCostLocalread-writecurrentNID Series card MSTI Port Configuration: MSTI10 Normal Port2 Configuration - Path Cost Valid values are in the range 0 to 200000000. Setting 0 means Auto path …
1.3.6.1.4.1.4756.20.500.20.1.1225ColumnnidMSTI10Port2PriorityLocalread-writecurrentNID Series card MSTI Port Configuration: MSTI8 Normal Port2 Configuration - Priority
1.3.6.1.4.1.4756.20.500.20.1.1226ColumnnidMSTI10Port3PathCostLocalread-writecurrentNID Series card MSTI Port Configuration: MSTI8 Normal Port3 Configuration - Path Cost Valid values are in the range 0 to 200000000. Setting 0 means Auto path c…
1.3.6.1.4.1.4756.20.500.20.1.1227ColumnnidMSTI10Port3PriorityLocalread-writecurrentNID Series card MSTI Port Configuration: MSTI10 Normal Port3 Configuration - Priority
1.3.6.1.4.1.4756.20.500.20.1.1228ColumnnidMSTI10Port4PathCostLocalread-writecurrentNID Series card MSTI Port Configuration: MSTI10 Normal Port4 Configuration - Path Cost Valid values are in the range 0 to 200000000. Setting 0 means Auto path …
1.3.6.1.4.1.4756.20.500.20.1.1229ColumnnidMSTI10Port4PriorityLocalread-writecurrentNID Series card MSTI Port Configuration: MSTI10 Normal Port4 Configuration - Priority
1.3.6.1.4.1.4756.20.500.20.1.1230ColumnnidMSTI10Port5PathCostLocalread-writecurrentNID Series card MSTI Port Configuration: MSTI10 Normal Port5 Configuration - Path Cost Valid values are in the range 0 to 200000000. Setting 0 means Auto path …
1.3.6.1.4.1.4756.20.500.20.1.1231ColumnnidMSTI10Port5PriorityLocalread-writecurrentNID Series card MSTI Port Configuration: MSTI10 Normal Port5 Configuration - Priority
1.3.6.1.4.1.4756.20.500.20.1.1232ColumnnidMSTI10Port6PathCostLocalread-writecurrentNID Series card MSTI Port Configuration: MSTI10 Normal Port6 Configuration - Path Cost Valid values are in the range 0 to 200000000. Setting 0 means Auto path …
1.3.6.1.4.1.4756.20.500.20.1.1233ColumnnidMSTI10Port6PriorityLocalread-writecurrentNID Series card MSTI Port Configuration: MSTI10 Normal Port6 Configuration - Priority
1.3.6.1.4.1.4756.20.500.20.1.1234ColumnnidMSTI10Port7PathCostLocalread-writecurrentNID Series card MSTI Port Configuration: MSTI10 Normal Port7 Configuration - Path Cost Valid values are in the range 0 to 200000000. Setting 0 means Auto path …
1.3.6.1.4.1.4756.20.500.20.1.1235ColumnnidMSTI10Port7PriorityLocalread-writecurrentNID Series card MSTI Port Configuration: MSTI10 Normal Port7 Configuration - Priority
1.3.6.1.4.1.4756.20.500.20.1.1236ColumnnidMSTI10Port8PathCostLocalread-writecurrentNID Series card MSTI Port Configuration: MSTI8 Normal Port8 Configuration - Path Cost Valid values are in the range 0 to 200000000. Setting 0 means Auto path c…
1.3.6.1.4.1.4756.20.500.20.1.1237ColumnnidMSTI10Port8PriorityLocalread-writecurrentNID Series card MSTI Port Configuration: MSTI10 Normal Port8 Configuration - Priority
1.3.6.1.4.1.4756.20.500.20.1.1238ColumnnidMSTI11AggregatedPathCostLocalread-writecurrentNID Series card MSTI Port Configuration: MSTI11 Aggregated Ports Configuration - Path Cost Valid values are in the range 0 to 200000000. Setting 0 means Auto p…
1.3.6.1.4.1.4756.20.500.20.1.1239ColumnnidMSTI11AggregatedPriorityLocalread-writecurrentNID Series card MSTI Port Configuration: MSTI11 Aggregated Ports Configuration - Priority
1.3.6.1.4.1.4756.20.500.20.1.1240ColumnnidMSTI11Port1PathCostLocalread-writecurrentNID Series card MSTI Port Configuration: MSTI11 Normal Port1 Configuration - Path Cost Valid values are in the range 0 to 200000000. Setting 0 means Auto path …
1.3.6.1.4.1.4756.20.500.20.1.1241ColumnnidMSTI11Port1PriorityLocalread-writecurrentNID Series card MSTI Port Configuration: MSTI11 Normal Port1 Configuration - Priority
1.3.6.1.4.1.4756.20.500.20.1.1242ColumnnidMSTI11Port2PathCostLocalread-writecurrentNID Series card MSTI Port Configuration: MSTI11 Normal Port2 Configuration - Path Cost Valid values are in the range 0 to 200000000. Setting 0 means Auto path …
1.3.6.1.4.1.4756.20.500.20.1.1243ColumnnidMSTI11Port2PriorityLocalread-writecurrentNID Series card MSTI Port Configuration: MSTI8 Normal Port2 Configuration - Priority
1.3.6.1.4.1.4756.20.500.20.1.1244ColumnnidMSTI11Port3PathCostLocalread-writecurrentNID Series card MSTI Port Configuration: MSTI8 Normal Port3 Configuration - Path Cost Valid values are in the range 0 to 200000000. Setting 0 means Auto path c…
1.3.6.1.4.1.4756.20.500.20.1.1245ColumnnidMSTI11Port3PriorityLocalread-writecurrentNID Series card MSTI Port Configuration: MSTI11 Normal Port3 Configuration - Priority
1.3.6.1.4.1.4756.20.500.20.1.1246ColumnnidMSTI11Port4PathCostLocalread-writecurrentNID Series card MSTI Port Configuration: MSTI11 Normal Port4 Configuration - Path Cost Valid values are in the range 0 to 200000000. Setting 0 means Auto path …
1.3.6.1.4.1.4756.20.500.20.1.1247ColumnnidMSTI11Port4PriorityLocalread-writecurrentNID Series card MSTI Port Configuration: MSTI11 Normal Port4 Configuration - Priority
1.3.6.1.4.1.4756.20.500.20.1.1248ColumnnidMSTI11Port5PathCostLocalread-writecurrentNID Series card MSTI Port Configuration: MSTI11 Normal Port5 Configuration - Path Cost Valid values are in the range 0 to 200000000. Setting 0 means Auto path …
1.3.6.1.4.1.4756.20.500.20.1.1249ColumnnidMSTI11Port5PriorityLocalread-writecurrentNID Series card MSTI Port Configuration: MSTI11 Normal Port5 Configuration - Priority
1.3.6.1.4.1.4756.20.500.20.1.1250ColumnnidMSTI11Port6PathCostLocalread-writecurrentNID Series card MSTI Port Configuration: MSTI11 Normal Port6 Configuration - Path Cost Valid values are in the range 0 to 200000000. Setting 0 means Auto path …
1.3.6.1.4.1.4756.20.500.20.1.1251ColumnnidMSTI11Port6PriorityLocalread-writecurrentNID Series card MSTI Port Configuration: MSTI11 Normal Port6 Configuration - Priority
1.3.6.1.4.1.4756.20.500.20.1.1252ColumnnidMSTI11Port7PathCostLocalread-writecurrentNID Series card MSTI Port Configuration: MSTI11 Normal Port7 Configuration - Path Cost Valid values are in the range 0 to 200000000. Setting 0 means Auto path …
1.3.6.1.4.1.4756.20.500.20.1.1253ColumnnidMSTI11Port7PriorityLocalread-writecurrentNID Series card MSTI Port Configuration: MSTI11 Normal Port7 Configuration - Priority
1.3.6.1.4.1.4756.20.500.20.1.1254ColumnnidMSTI11Port8PathCostLocalread-writecurrentNID Series card MSTI Port Configuration: MSTI8 Normal Port8 Configuration - Path Cost Valid values are in the range 0 to 200000000. Setting 0 means Auto path c…
1.3.6.1.4.1.4756.20.500.20.1.1255ColumnnidMSTI11Port8PriorityLocalread-writecurrentNID Series card MSTI Port Configuration: MSTI11 Normal Port8 Configuration - Priority
1.3.6.1.4.1.4756.20.500.20.1.1256ColumnnidMSTI12AggregatedPathCostLocalread-writecurrentNID Series card MSTI Port Configuration: MSTI12 Aggregated Ports Configuration - Path Cost Valid values are in the range 0 to 200000000. Setting 0 means Auto p…
1.3.6.1.4.1.4756.20.500.20.1.1257ColumnnidMSTI12AggregatedPriorityLocalread-writecurrentNID Series card MSTI Port Configuration: MSTI12 Aggregated Ports Configuration - Priority
1.3.6.1.4.1.4756.20.500.20.1.1258ColumnnidMSTI12Port1PathCostLocalread-writecurrentNID Series card MSTI Port Configuration: MSTI12 Normal Port1 Configuration - Path Cost Valid values are in the range 0 to 200000000. Setting 0 means Auto path …
1.3.6.1.4.1.4756.20.500.20.1.1259ColumnnidMSTI12Port1PriorityLocalread-writecurrentNID Series card MSTI Port Configuration: MSTI12 Normal Port1 Configuration - Priority
1.3.6.1.4.1.4756.20.500.20.1.1260ColumnnidMSTI12Port2PathCostLocalread-writecurrentNID Series card MSTI Port Configuration: MSTI12 Normal Port2 Configuration - Path Cost Valid values are in the range 0 to 200000000. Setting 0 means Auto path …
1.3.6.1.4.1.4756.20.500.20.1.1261ColumnnidMSTI12Port2PriorityLocalread-writecurrentNID Series card MSTI Port Configuration: MSTI8 Normal Port2 Configuration - Priority
1.3.6.1.4.1.4756.20.500.20.1.1262ColumnnidMSTI12Port3PathCostLocalread-writecurrentNID Series card MSTI Port Configuration: MSTI8 Normal Port3 Configuration - Path Cost Valid values are in the range 0 to 200000000. Setting 0 means Auto path c…
1.3.6.1.4.1.4756.20.500.20.1.1263ColumnnidMSTI12Port3PriorityLocalread-writecurrentNID Series card MSTI Port Configuration: MSTI12 Normal Port3 Configuration - Priority
1.3.6.1.4.1.4756.20.500.20.1.1264ColumnnidMSTI12Port4PathCostLocalread-writecurrentNID Series card MSTI Port Configuration: MSTI12 Normal Port4 Configuration - Path Cost Valid values are in the range 0 to 200000000. Setting 0 means Auto path …
1.3.6.1.4.1.4756.20.500.20.1.1265ColumnnidMSTI12Port4PriorityLocalread-writecurrentNID Series card MSTI Port Configuration: MSTI12 Normal Port4 Configuration - Priority
1.3.6.1.4.1.4756.20.500.20.1.1266ColumnnidMSTI12Port5PathCostLocalread-writecurrentNID Series card MSTI Port Configuration: MSTI12 Normal Port5 Configuration - Path Cost Valid values are in the range 0 to 200000000. Setting 0 means Auto path …
1.3.6.1.4.1.4756.20.500.20.1.1267ColumnnidMSTI12Port5PriorityLocalread-writecurrentNID Series card MSTI Port Configuration: MSTI12 Normal Port5 Configuration - Priority
1.3.6.1.4.1.4756.20.500.20.1.1268ColumnnidMSTI12Port6PathCostLocalread-writecurrentNID Series card MSTI Port Configuration: MSTI12 Normal Port6 Configuration - Path Cost Valid values are in the range 0 to 200000000. Setting 0 means Auto path …
1.3.6.1.4.1.4756.20.500.20.1.1269ColumnnidMSTI12Port6PriorityLocalread-writecurrentNID Series card MSTI Port Configuration: MSTI12 Normal Port6 Configuration - Priority
1.3.6.1.4.1.4756.20.500.20.1.1270ColumnnidMSTI12Port7PathCostLocalread-writecurrentNID Series card MSTI Port Configuration: MSTI12 Normal Port7 Configuration - Path Cost Valid values are in the range 0 to 200000000. Setting 0 means Auto path …
1.3.6.1.4.1.4756.20.500.20.1.1271ColumnnidMSTI12Port7PriorityLocalread-writecurrentNID Series card MSTI Port Configuration: MSTI12 Normal Port7 Configuration - Priority
1.3.6.1.4.1.4756.20.500.20.1.1272ColumnnidMSTI12Port8PathCostLocalread-writecurrentNID Series card MSTI Port Configuration: MSTI8 Normal Port8 Configuration - Path Cost Valid values are in the range 0 to 200000000. Setting 0 means Auto path c…
1.3.6.1.4.1.4756.20.500.20.1.1273ColumnnidMSTI12Port8PriorityLocalread-writecurrentNID Series card MSTI Port Configuration: MSTI12 Normal Port8 Configuration - Priority
1.3.6.1.4.1.4756.20.500.20.1.1274ColumnnidMSTI13AggregatedPathCostLocalread-writecurrentNID Series card MSTI Port Configuration: MSTI13 Aggregated Ports Configuration - Path Cost Valid values are in the range 0 to 200000000. Setting 0 means Auto p…
1.3.6.1.4.1.4756.20.500.20.1.1275ColumnnidMSTI13AggregatedPriorityLocalread-writecurrentNID Series card MSTI Port Configuration: MSTI13 Aggregated Ports Configuration - Priority
1.3.6.1.4.1.4756.20.500.20.1.1276ColumnnidMSTI13Port1PathCostLocalread-writecurrentNID Series card MSTI Port Configuration: MSTI13 Normal Port1 Configuration - Path Cost Valid values are in the range 0 to 200000000. Setting 0 means Auto path …
1.3.6.1.4.1.4756.20.500.20.1.1277ColumnnidMSTI13Port1PriorityLocalread-writecurrentNID Series card MSTI Port Configuration: MSTI13 Normal Port1 Configuration - Priority
1.3.6.1.4.1.4756.20.500.20.1.1278ColumnnidMSTI13Port2PathCostLocalread-writecurrentNID Series card MSTI Port Configuration: MSTI13 Normal Port2 Configuration - Path Cost Valid values are in the range 0 to 200000000. Setting 0 means Auto path …
1.3.6.1.4.1.4756.20.500.20.1.1279ColumnnidMSTI13Port2PriorityLocalread-writecurrentNID Series card MSTI Port Configuration: MSTI8 Normal Port2 Configuration - Priority
1.3.6.1.4.1.4756.20.500.20.1.1280ColumnnidMSTI13Port3PathCostLocalread-writecurrentNID Series card MSTI Port Configuration: MSTI8 Normal Port3 Configuration - Path Cost Valid values are in the range 0 to 200000000. Setting 0 means Auto path c…
1.3.6.1.4.1.4756.20.500.20.1.1281ColumnnidMSTI13Port3PriorityLocalread-writecurrentNID Series card MSTI Port Configuration: MSTI13 Normal Port3 Configuration - Priority
1.3.6.1.4.1.4756.20.500.20.1.1282ColumnnidMSTI13Port4PathCostLocalread-writecurrentNID Series card MSTI Port Configuration: MSTI13 Normal Port4 Configuration - Path Cost Valid values are in the range 0 to 200000000. Setting 0 means Auto path …
1.3.6.1.4.1.4756.20.500.20.1.1283ColumnnidMSTI13Port4PriorityLocalread-writecurrentNID Series card MSTI Port Configuration: MSTI13 Normal Port4 Configuration - Priority
1.3.6.1.4.1.4756.20.500.20.1.1284ColumnnidMSTI13Port5PathCostLocalread-writecurrentNID Series card MSTI Port Configuration: MSTI13 Normal Port5 Configuration - Path Cost Valid values are in the range 0 to 200000000. Setting 0 means Auto path …
1.3.6.1.4.1.4756.20.500.20.1.1285ColumnnidMSTI13Port5PriorityLocalread-writecurrentNID Series card MSTI Port Configuration: MSTI13 Normal Port5 Configuration - Priority
1.3.6.1.4.1.4756.20.500.20.1.1286ColumnnidMSTI13Port6PathCostLocalread-writecurrentNID Series card MSTI Port Configuration: MSTI13 Normal Port6 Configuration - Path Cost Valid values are in the range 0 to 200000000. Setting 0 means Auto path …
1.3.6.1.4.1.4756.20.500.20.1.1287ColumnnidMSTI13Port6PriorityLocalread-writecurrentNID Series card MSTI Port Configuration: MSTI13 Normal Port6 Configuration - Priority
1.3.6.1.4.1.4756.20.500.20.1.1288ColumnnidMSTI13Port7PathCostLocalread-writecurrentNID Series card MSTI Port Configuration: MSTI13 Normal Port7 Configuration - Path Cost Valid values are in the range 0 to 200000000. Setting 0 means Auto path …
1.3.6.1.4.1.4756.20.500.20.1.1289ColumnnidMSTI13Port7PriorityLocalread-writecurrentNID Series card MSTI Port Configuration: MSTI13 Normal Port7 Configuration - Priority
1.3.6.1.4.1.4756.20.500.20.1.1290ColumnnidMSTI13Port8PathCostLocalread-writecurrentNID Series card MSTI Port Configuration: MSTI8 Normal Port8 Configuration - Path Cost Valid values are in the range 0 to 200000000. Setting 0 means Auto path c…
1.3.6.1.4.1.4756.20.500.20.1.1291ColumnnidMSTI13Port8PriorityLocalread-writecurrentNID Series card MSTI Port Configuration: MSTI13 Normal Port8 Configuration - Priority
1.3.6.1.4.1.4756.20.500.20.1.1292ColumnnidMSTI14AggregatedPathCostLocalread-writecurrentNID Series card MSTI Port Configuration: MSTI14 Aggregated Ports Configuration - Path Cost Valid values are in the range 0 to 200000000. Setting 0 means Auto p…
1.3.6.1.4.1.4756.20.500.20.1.1293ColumnnidMSTI14AggregatedPriorityLocalread-writecurrentNID Series card MSTI Port Configuration: MSTI14 Aggregated Ports Configuration - Priority
1.3.6.1.4.1.4756.20.500.20.1.1294ColumnnidMSTI14Port1PathCostLocalread-writecurrentNID Series card MSTI Port Configuration: MSTI14 Normal Port1 Configuration - Path Cost Valid values are in the range 0 to 200000000. Setting 0 means Auto path …
1.3.6.1.4.1.4756.20.500.20.1.1295ColumnnidMSTI14Port1PriorityLocalread-writecurrentNID Series card MSTI Port Configuration: MSTI14 Normal Port1 Configuration - Priority
1.3.6.1.4.1.4756.20.500.20.1.1296ColumnnidMSTI14Port2PathCostLocalread-writecurrentNID Series card MSTI Port Configuration: MSTI14 Normal Port2 Configuration - Path Cost Valid values are in the range 0 to 200000000. Setting 0 means Auto path …
1.3.6.1.4.1.4756.20.500.20.1.1297ColumnnidMSTI14Port2PriorityLocalread-writecurrentNID Series card MSTI Port Configuration: MSTI8 Normal Port2 Configuration - Priority
1.3.6.1.4.1.4756.20.500.20.1.1298ColumnnidMSTI14Port3PathCostLocalread-writecurrentNID Series card MSTI Port Configuration: MSTI8 Normal Port3 Configuration - Path Cost Valid values are in the range 0 to 200000000. Setting 0 means Auto path c…
1.3.6.1.4.1.4756.20.500.20.1.1299ColumnnidMSTI14Port3PriorityLocalread-writecurrentNID Series card MSTI Port Configuration: MSTI14 Normal Port3 Configuration - Priority
1.3.6.1.4.1.4756.20.500.20.1.1300ColumnnidMSTI14Port4PathCostLocalread-writecurrentNID Series card MSTI Port Configuration: MSTI14 Normal Port4 Configuration - Path Cost Valid values are in the range 0 to 200000000. Setting 0 means Auto path …
1.3.6.1.4.1.4756.20.500.20.1.1301ColumnnidMSTI14Port4PriorityLocalread-writecurrentNID Series card MSTI Port Configuration: MSTI14 Normal Port4 Configuration - Priority
1.3.6.1.4.1.4756.20.500.20.1.1302ColumnnidMSTI14Port5PathCostLocalread-writecurrentNID Series card MSTI Port Configuration: MSTI14 Normal Port5 Configuration - Path Cost Valid values are in the range 0 to 200000000. Setting 0 means Auto path …
1.3.6.1.4.1.4756.20.500.20.1.1303ColumnnidMSTI14Port5PriorityLocalread-writecurrentNID Series card MSTI Port Configuration: MSTI14 Normal Port5 Configuration - Priority
1.3.6.1.4.1.4756.20.500.20.1.1304ColumnnidMSTI14Port6PathCostLocalread-writecurrentNID Series card MSTI Port Configuration: MSTI14 Normal Port6 Configuration - Path Cost Valid values are in the range 0 to 200000000. Setting 0 means Auto path …
1.3.6.1.4.1.4756.20.500.20.1.1305ColumnnidMSTI14Port6PriorityLocalread-writecurrentNID Series card MSTI Port Configuration: MSTI14 Normal Port6 Configuration - Priority
1.3.6.1.4.1.4756.20.500.20.1.1306ColumnnidMSTI14Port7PathCostLocalread-writecurrentNID Series card MSTI Port Configuration: MSTI14 Normal Port7 Configuration - Path Cost Valid values are in the range 0 to 200000000. Setting 0 means Auto path …
1.3.6.1.4.1.4756.20.500.20.1.1307ColumnnidMSTI14Port7PriorityLocalread-writecurrentNID Series card MSTI Port Configuration: MSTI14 Normal Port7 Configuration - Priority
1.3.6.1.4.1.4756.20.500.20.1.1308ColumnnidMSTI14Port8PathCostLocalread-writecurrentNID Series card MSTI Port Configuration: MSTI8 Normal Port8 Configuration - Path Cost Valid values are in the range 0 to 200000000. Setting 0 means Auto path c…
1.3.6.1.4.1.4756.20.500.20.1.1309ColumnnidMSTI14Port8PriorityLocalread-writecurrentNID Series card MSTI Port Configuration: MSTI14 Normal Port8 Configuration - Priority
1.3.6.1.4.1.4756.20.500.20.1.1310ColumnnidMSTI15AggregatedPathCostLocalread-writecurrentNID Series card MSTI Port Configuration: MSTI15 Aggregated Ports Configuration - Path Cost Valid values are in the range 0 to 200000000. Setting 0 means Auto p…
1.3.6.1.4.1.4756.20.500.20.1.1311ColumnnidMSTI15AggregatedPriorityLocalread-writecurrentNID Series card MSTI Port Configuration: MSTI15 Aggregated Ports Configuration - Priority
1.3.6.1.4.1.4756.20.500.20.1.1312ColumnnidMSTI15Port1PathCostLocalread-writecurrentNID Series card MSTI Port Configuration: MSTI15 Normal Port1 Configuration - Path Cost Valid values are in the range 0 to 200000000. Setting 0 means Auto path …
1.3.6.1.4.1.4756.20.500.20.1.1313ColumnnidMSTI15Port1PriorityLocalread-writecurrentNID Series card MSTI Port Configuration: MSTI15 Normal Port1 Configuration - Priority
1.3.6.1.4.1.4756.20.500.20.1.1314ColumnnidMSTI15Port2PathCostLocalread-writecurrentNID Series card MSTI Port Configuration: MSTI15 Normal Port2 Configuration - Path Cost Valid values are in the range 0 to 200000000. Setting 0 means Auto path …
1.3.6.1.4.1.4756.20.500.20.1.1315ColumnnidMSTI15Port2PriorityLocalread-writecurrentNID Series card MSTI Port Configuration: MSTI8 Normal Port2 Configuration - Priority
1.3.6.1.4.1.4756.20.500.20.1.1316ColumnnidMSTI15Port3PathCostLocalread-writecurrentNID Series card MSTI Port Configuration: MSTI8 Normal Port3 Configuration - Path Cost Valid values are in the range 0 to 200000000. Setting 0 means Auto path c…
1.3.6.1.4.1.4756.20.500.20.1.1317ColumnnidMSTI15Port3PriorityLocalread-writecurrentNID Series card MSTI Port Configuration: MSTI15 Normal Port3 Configuration - Priority
1.3.6.1.4.1.4756.20.500.20.1.1318ColumnnidMSTI15Port4PathCostLocalread-writecurrentNID Series card MSTI Port Configuration: MSTI15 Normal Port4 Configuration - Path Cost Valid values are in the range 0 to 200000000. Setting 0 means Auto path …
1.3.6.1.4.1.4756.20.500.20.1.1319ColumnnidMSTI15Port4PriorityLocalread-writecurrentNID Series card MSTI Port Configuration: MSTI15 Normal Port4 Configuration - Priority
1.3.6.1.4.1.4756.20.500.20.1.1320ColumnnidMSTI15Port5PathCostLocalread-writecurrentNID Series card MSTI Port Configuration: MSTI15 Normal Port5 Configuration - Path Cost Valid values are in the range 0 to 200000000. Setting 0 means Auto path …
1.3.6.1.4.1.4756.20.500.20.1.1321ColumnnidMSTI15Port5PriorityLocalread-writecurrentNID Series card MSTI Port Configuration: MSTI15 Normal Port5 Configuration - Priority
1.3.6.1.4.1.4756.20.500.20.1.1322ColumnnidMSTI15Port6PathCostLocalread-writecurrentNID Series card MSTI Port Configuration: MSTI15 Normal Port6 Configuration - Path Cost Valid values are in the range 0 to 200000000. Setting 0 means Auto path …
1.3.6.1.4.1.4756.20.500.20.1.1323ColumnnidMSTI15Port6PriorityLocalread-writecurrentNID Series card MSTI Port Configuration: MSTI15 Normal Port6 Configuration - Priority
1.3.6.1.4.1.4756.20.500.20.1.1324ColumnnidMSTI15Port7PathCostLocalread-writecurrentNID Series card MSTI Port Configuration: MSTI15 Normal Port7 Configuration - Path Cost Valid values are in the range 0 to 200000000. Setting 0 means Auto path …
1.3.6.1.4.1.4756.20.500.20.1.1325ColumnnidMSTI15Port7PriorityLocalread-writecurrentNID Series card MSTI Port Configuration: MSTI15 Normal Port7 Configuration - Priority
1.3.6.1.4.1.4756.20.500.20.1.1326ColumnnidMSTI15Port8PathCostLocalread-writecurrentNID Series card MSTI Port Configuration: MSTI8 Normal Port8 Configuration - Path Cost Valid values are in the range 0 to 200000000. Setting 0 means Auto path c…
1.3.6.1.4.1.4756.20.500.20.1.1327ColumnnidMSTI15Port8PriorityLocalread-writecurrentNID Series card MSTI Port Configuration: MSTI15 Normal Port8 Configuration - Priority
1.3.6.1.4.1.4756.20.500.20.1.1328ColumnnidCISTBridgeIDLocalread-onlycurrentNID Series card STP Bridges status: CIST - Bridge ID
1.3.6.1.4.1.4756.20.500.20.1.1329ColumnnidCISTRootIDLocalread-onlycurrentNID Series card STP Bridges status: CIST - Root ID
1.3.6.1.4.1.4756.20.500.20.1.1330ColumnnidCISTRootPortLocalread-onlycurrentNID Series card STP Bridges status: CIST - Root Port
1.3.6.1.4.1.4756.20.500.20.1.1331ColumnnidCISTRootCostLocalread-onlycurrentNID Series card STP Bridges status: CIST - Root Cost
1.3.6.1.4.1.4756.20.500.20.1.1332ColumnnidCISTTopologyFlagLocalread-onlycurrentNID Series card STP Bridges status: CIST - Topology Flag
1.3.6.1.4.1.4756.20.500.20.1.1333ColumnnidCISTTopologyChangeLastLocalread-onlycurrentNID Series card STP Bridges status: CIST - Topology Change Last
1.3.6.1.4.1.4756.20.500.20.1.1334ColumnnidMSTI1BridgeIDLocalread-onlycurrentNID Series card STP Bridges status: MSTI1 - Bridge ID
1.3.6.1.4.1.4756.20.500.20.1.1335ColumnnidMSTI1RootIDLocalread-onlycurrentNID Series card STP Bridges status: MSTI1 - Root ID
1.3.6.1.4.1.4756.20.500.20.1.1336ColumnnidMSTI1RootPortLocalread-onlycurrentNID Series card STP Bridges status: MSTI1 - Root ID
1.3.6.1.4.1.4756.20.500.20.1.1337ColumnnidMSTI1RootCostLocalread-onlycurrentNID Series card STP Bridges status: MSTI1 - Root Cost
1.3.6.1.4.1.4756.20.500.20.1.1338ColumnnidMSTI1TopologyFlagLocalread-onlycurrentNID Series card STP Bridges status: MSTI1 - Topology Flag
1.3.6.1.4.1.4756.20.500.20.1.1339ColumnnidMSTI1TopologyChangeLastLocalread-onlycurrentNID Series card STP Bridges status: MSTI1 - Topology Change Last
1.3.6.1.4.1.4756.20.500.20.1.1340ColumnnidMSTI2BridgeIDLocalread-onlycurrentNID Series card STP Bridges status: MSTI2 - Bridge ID
1.3.6.1.4.1.4756.20.500.20.1.1341ColumnnidMSTI2RootIDLocalread-onlycurrentNID Series card STP Bridges status: MSTI2 - Root ID
1.3.6.1.4.1.4756.20.500.20.1.1342ColumnnidMSTI2RootPortLocalread-onlycurrentNID Series card STP Bridges status: MSTI2 - Root ID
1.3.6.1.4.1.4756.20.500.20.1.1343ColumnnidMSTI2RootCostLocalread-onlycurrentNID Series card STP Bridges status: MSTI2 - Root Cost
1.3.6.1.4.1.4756.20.500.20.1.1344ColumnnidMSTI2TopologyFlagLocalread-onlycurrentNID Series card STP Bridges status: MSTI2 - Topology Flag
1.3.6.1.4.1.4756.20.500.20.1.1345ColumnnidMSTI2TopologyChangeLastLocalread-onlycurrentNID Series card STP Bridges status: MSTI2 - Topology Change Last
1.3.6.1.4.1.4756.20.500.20.1.1346ColumnnidMSTI3BridgeIDLocalread-onlycurrentNID Series card STP Bridges status: MSTI3 - Bridge ID
1.3.6.1.4.1.4756.20.500.20.1.1347ColumnnidMSTI3RootIDLocalread-onlycurrentNID Series card STP Bridges status: MSTI3 - Root ID
1.3.6.1.4.1.4756.20.500.20.1.1348ColumnnidMSTI3RootPortLocalread-onlycurrentNID Series card STP Bridges status: MSTI3 - Root ID
1.3.6.1.4.1.4756.20.500.20.1.1349ColumnnidMSTI3RootCostLocalread-onlycurrentNID Series card STP Bridges status: MSTI3 - Root Cost
1.3.6.1.4.1.4756.20.500.20.1.1350ColumnnidMSTI3TopologyFlagLocalread-onlycurrentNID Series card STP Bridges status: MSTI3 - Topology Flag
1.3.6.1.4.1.4756.20.500.20.1.1351ColumnnidMSTI3TopologyChangeLastLocalread-onlycurrentNID Series card STP Bridges status: MSTI3 - Topology Change Last
1.3.6.1.4.1.4756.20.500.20.1.1352ColumnnidMSTI4BridgeIDLocalread-onlycurrentNID Series card STP Bridges status: MSTI4 - Bridge ID
1.3.6.1.4.1.4756.20.500.20.1.1353ColumnnidMSTI4RootIDLocalread-onlycurrentNID Series card STP Bridges status: MSTI4 - Root ID
1.3.6.1.4.1.4756.20.500.20.1.1354ColumnnidMSTI4RootPortLocalread-onlycurrentNID Series card STP Bridges status: MSTI4 - Root ID
1.3.6.1.4.1.4756.20.500.20.1.1355ColumnnidMSTI4RootCostLocalread-onlycurrentNID Series card STP Bridges status: MSTI4 - Root Cost
1.3.6.1.4.1.4756.20.500.20.1.1356ColumnnidMSTI4TopologyFlagLocalread-onlycurrentNID Series card STP Bridges status: MSTI4 - Topology Flag
1.3.6.1.4.1.4756.20.500.20.1.1357ColumnnidMSTI4TopologyChangeLastLocalread-onlycurrentNID Series card STP Bridges status: MSTI4 - Topology Change Last
1.3.6.1.4.1.4756.20.500.20.1.1358ColumnnidMSTI5BridgeIDLocalread-onlycurrentNID Series card STP Bridges status: MSTI5 - Bridge ID
1.3.6.1.4.1.4756.20.500.20.1.1359ColumnnidMSTI5RootIDLocalread-onlycurrentNID Series card STP Bridges status: MSTI5 - Root ID
1.3.6.1.4.1.4756.20.500.20.1.1360ColumnnidMSTI5RootPortLocalread-onlycurrentNID Series card STP Bridges status: MSTI5 - Root ID
1.3.6.1.4.1.4756.20.500.20.1.1361ColumnnidMSTI5RootCostLocalread-onlycurrentNID Series card STP Bridges status: MSTI5 - Root Cost
1.3.6.1.4.1.4756.20.500.20.1.1362ColumnnidMSTI5TopologyFlagLocalread-onlycurrentNID Series card STP Bridges status: MSTI5 - Topology Flag
1.3.6.1.4.1.4756.20.500.20.1.1363ColumnnidMSTI5TopologyChangeLastLocalread-onlycurrentNID Series card STP Bridges status: MSTI5 - Topology Change Last
1.3.6.1.4.1.4756.20.500.20.1.1364ColumnnidMSTI6BridgeIDLocalread-onlycurrentNID Series card STP Bridges status: MSTI6 - Bridge ID
1.3.6.1.4.1.4756.20.500.20.1.1365ColumnnidMSTI6RootIDLocalread-onlycurrentNID Series card STP Bridges status: MSTI6 - Root ID
1.3.6.1.4.1.4756.20.500.20.1.1366ColumnnidMSTI6RootPortLocalread-onlycurrentNID Series card STP Bridges status: MSTI6 - Root ID
1.3.6.1.4.1.4756.20.500.20.1.1367ColumnnidMSTI6RootCostLocalread-onlycurrentNID Series card STP Bridges status: MSTI6 - Root Cost
1.3.6.1.4.1.4756.20.500.20.1.1368ColumnnidMSTI6TopologyFlagLocalread-onlycurrentNID Series card STP Bridges status: MSTI6 - Topology Flag
1.3.6.1.4.1.4756.20.500.20.1.1369ColumnnidMSTI6TopologyChangeLastLocalread-onlycurrentNID Series card STP Bridges status: MSTI6 - Topology Change Last
1.3.6.1.4.1.4756.20.500.20.1.1370ColumnnidMSTI7BridgeIDLocalread-onlycurrentNID Series card STP Bridges status: MSTI7 - Bridge ID
1.3.6.1.4.1.4756.20.500.20.1.1371ColumnnidMSTI7RootIDLocalread-onlycurrentNID Series card STP Bridges status: MSTI7 - Root ID
1.3.6.1.4.1.4756.20.500.20.1.1372ColumnnidMSTI7RootPortLocalread-onlycurrentNID Series card STP Bridges status: MSTI7 - Root ID
1.3.6.1.4.1.4756.20.500.20.1.1373ColumnnidMSTI7RootCostLocalread-onlycurrentNID Series card STP Bridges status: MSTI7 - Root Cost
1.3.6.1.4.1.4756.20.500.20.1.1374ColumnnidMSTI7TopologyFlagLocalread-onlycurrentNID Series card STP Bridges status: MSTI7 - Topology Flag
1.3.6.1.4.1.4756.20.500.20.1.1375ColumnnidMSTI7TopologyChangeLastLocalread-onlycurrentNID Series card STP Bridges status: MSTI7 - Topology Change Last
1.3.6.1.4.1.4756.20.500.20.1.1376ColumnnidMSTI8BridgeIDLocalread-onlycurrentNID Series card STP Bridges status: MSTI8 - Bridge ID
1.3.6.1.4.1.4756.20.500.20.1.1377ColumnnidMSTI8RootIDLocalread-onlycurrentNID Series card STP Bridges status: MSTI8 - Root ID
1.3.6.1.4.1.4756.20.500.20.1.1378ColumnnidMSTI8RootPortLocalread-onlycurrentNID Series card STP Bridges status: MSTI8 - Root ID
1.3.6.1.4.1.4756.20.500.20.1.1379ColumnnidMSTI8RootCostLocalread-onlycurrentNID Series card STP Bridges status: MSTI8 - Root Cost
1.3.6.1.4.1.4756.20.500.20.1.1380ColumnnidMSTI8TopologyFlagLocalread-onlycurrentNID Series card STP Bridges status: MSTI8 - Topology Flag
1.3.6.1.4.1.4756.20.500.20.1.1381ColumnnidMSTI8TopologyChangeLastLocalread-onlycurrentNID Series card STP Bridges status: MSTI8 - Topology Change Last
1.3.6.1.4.1.4756.20.500.20.1.1382ColumnnidMSTI9BridgeIDLocalread-onlycurrentNID Series card STP Bridges status: MSTI9 - Bridge ID
1.3.6.1.4.1.4756.20.500.20.1.1383ColumnnidMSTI9RootIDLocalread-onlycurrentNID Series card STP Bridges status: MSTI9 - Root ID
1.3.6.1.4.1.4756.20.500.20.1.1384ColumnnidMSTI9RootPortLocalread-onlycurrentNID Series card STP Bridges status: MSTI9 - Root ID
1.3.6.1.4.1.4756.20.500.20.1.1385ColumnnidMSTI9RootCostLocalread-onlycurrentNID Series card STP Bridges status: MSTI9 - Root Cost
1.3.6.1.4.1.4756.20.500.20.1.1386ColumnnidMSTI9TopologyFlagLocalread-onlycurrentNID Series card STP Bridges status: MSTI9 - Topology Flag
1.3.6.1.4.1.4756.20.500.20.1.1387ColumnnidMSTI9TopologyChangeLastLocalread-onlycurrentNID Series card STP Bridges status: MSTI9 - Topology Change Last
1.3.6.1.4.1.4756.20.500.20.1.1388ColumnnidMSTI10BridgeIDLocalread-onlycurrentNID Series card STP Bridges status: MSTI10 - Bridge ID
1.3.6.1.4.1.4756.20.500.20.1.1389ColumnnidMSTI10RootIDLocalread-onlycurrentNID Series card STP Bridges status: MSTI10 - Root ID
1.3.6.1.4.1.4756.20.500.20.1.1390ColumnnidMSTI10RootPortLocalread-onlycurrentNID Series card STP Bridges status: MSTI10 - Root ID
1.3.6.1.4.1.4756.20.500.20.1.1391ColumnnidMSTI10RootCostLocalread-onlycurrentNID Series card STP Bridges status: MSTI10 - Root Cost
1.3.6.1.4.1.4756.20.500.20.1.1392ColumnnidMSTI10TopologyFlagLocalread-onlycurrentNID Series card STP Bridges status: MSTI10 - Topology Flag
1.3.6.1.4.1.4756.20.500.20.1.1393ColumnnidMSTI10TopologyChangeLastLocalread-onlycurrentNID Series card STP Bridges status: MSTI10 - Topology Change Last
1.3.6.1.4.1.4756.20.500.20.1.1394ColumnnidMSTI11BridgeIDLocalread-onlycurrentNID Series card STP Bridges status: MSTI11 - Bridge ID
1.3.6.1.4.1.4756.20.500.20.1.1395ColumnnidMSTI11RootIDLocalread-onlycurrentNID Series card STP Bridges status: MSTI11 - Root ID
1.3.6.1.4.1.4756.20.500.20.1.1396ColumnnidMSTI11RootPortLocalread-onlycurrentNID Series card STP Bridges status: MSTI11 - Root ID
1.3.6.1.4.1.4756.20.500.20.1.1397ColumnnidMSTI11RootCostLocalread-onlycurrentNID Series card STP Bridges status: MSTI11 - Root Cost
1.3.6.1.4.1.4756.20.500.20.1.1398ColumnnidMSTI11TopologyFlagLocalread-onlycurrentNID Series card STP Bridges status: MSTI11 - Topology Flag
1.3.6.1.4.1.4756.20.500.20.1.1399ColumnnidMSTI11TopologyChangeLastLocalread-onlycurrentNID Series card STP Bridges status: MSTI11 - Topology Change Last
1.3.6.1.4.1.4756.20.500.20.1.1400ColumnnidMSTI12BridgeIDLocalread-onlycurrentNID Series card STP Bridges status: MSTI12 - Bridge ID
1.3.6.1.4.1.4756.20.500.20.1.1401ColumnnidMSTI12RootIDLocalread-onlycurrentNID Series card STP Bridges status: MSTI12 - Root ID
1.3.6.1.4.1.4756.20.500.20.1.1402ColumnnidMSTI12RootPortLocalread-onlycurrentNID Series card STP Bridges status: MSTI12 - Root ID
1.3.6.1.4.1.4756.20.500.20.1.1403ColumnnidMSTI12RootCostLocalread-onlycurrentNID Series card STP Bridges status: MSTI12 - Root Cost
1.3.6.1.4.1.4756.20.500.20.1.1404ColumnnidMSTI12TopologyFlagLocalread-onlycurrentNID Series card STP Bridges status: MSTI12 - Topology Flag
1.3.6.1.4.1.4756.20.500.20.1.1405ColumnnidMSTI12TopologyChangeLastLocalread-onlycurrentNID Series card STP Bridges status: MSTI12 - Topology Change Last
1.3.6.1.4.1.4756.20.500.20.1.1406ColumnnidMSTI13BridgeIDLocalread-onlycurrentNID Series card STP Bridges status: MSTI13 - Bridge ID
1.3.6.1.4.1.4756.20.500.20.1.1407ColumnnidMSTI13RootIDLocalread-onlycurrentNID Series card STP Bridges status: MSTI13 - Root ID
1.3.6.1.4.1.4756.20.500.20.1.1408ColumnnidMSTI13RootPortLocalread-onlycurrentNID Series card STP Bridges status: MSTI13 - Root ID
1.3.6.1.4.1.4756.20.500.20.1.1409ColumnnidMSTI13RootCostLocalread-onlycurrentNID Series card STP Bridges status: MSTI13 - Root Cost
1.3.6.1.4.1.4756.20.500.20.1.1410ColumnnidMSTI13TopologyFlagLocalread-onlycurrentNID Series card STP Bridges status: MSTI13 - Topology Flag
1.3.6.1.4.1.4756.20.500.20.1.1411ColumnnidMSTI13TopologyChangeLastLocalread-onlycurrentNID Series card STP Bridges status: MSTI13 - Topology Change Last
1.3.6.1.4.1.4756.20.500.20.1.1412ColumnnidMSTI14BridgeIDLocalread-onlycurrentNID Series card STP Bridges status: MSTI14 - Bridge ID
1.3.6.1.4.1.4756.20.500.20.1.1413ColumnnidMSTI14RootIDLocalread-onlycurrentNID Series card STP Bridges status: MSTI14 - Root ID
1.3.6.1.4.1.4756.20.500.20.1.1414ColumnnidMSTI14RootPortLocalread-onlycurrentNID Series card STP Bridges status: MSTI14 - Root ID
1.3.6.1.4.1.4756.20.500.20.1.1415ColumnnidMSTI14RootCostLocalread-onlycurrentNID Series card STP Bridges status: MSTI14 - Root Cost
1.3.6.1.4.1.4756.20.500.20.1.1416ColumnnidMSTI14TopologyFlagLocalread-onlycurrentNID Series card STP Bridges status: MSTI14 - Topology Flag
1.3.6.1.4.1.4756.20.500.20.1.1417ColumnnidMSTI14TopologyChangeLastLocalread-onlycurrentNID Series card STP Bridges status: MSTI14 - Topology Change Last
1.3.6.1.4.1.4756.20.500.20.1.1418ColumnnidMSTI15BridgeIDLocalread-onlycurrentNID Series card STP Bridges status: MSTI15 - Bridge ID
1.3.6.1.4.1.4756.20.500.20.1.1419ColumnnidMSTI15RootIDLocalread-onlycurrentNID Series card STP Bridges status: MSTI15 - Root ID
1.3.6.1.4.1.4756.20.500.20.1.1420ColumnnidMSTI15RootPortLocalread-onlycurrentNID Series card STP Bridges status: MSTI15 - Root ID
1.3.6.1.4.1.4756.20.500.20.1.1421ColumnnidMSTI15RootCostLocalread-onlycurrentNID Series card STP Bridges status: MSTI15 - Root Cost
1.3.6.1.4.1.4756.20.500.20.1.1422ColumnnidMSTI15TopologyFlagLocalread-onlycurrentNID Series card STP Bridges status: MSTI15 - Topology Flag
1.3.6.1.4.1.4756.20.500.20.1.1423ColumnnidMSTI15TopologyChangeLastLocalread-onlycurrentNID Series card STP Bridges status: MSTI15 - Topology Change Last
1.3.6.1.4.1.4756.20.500.20.1.1424ColumnnidSTPPortStatusInst1PortLocalread-onlycurrentNID Series card STP Port status: Instance1 - Port
1.3.6.1.4.1.4756.20.500.20.1.1425ColumnnidSTPPortStatusInst1CISTRoleLocalread-onlycurrentNID Series card STP Port status: Instance1 - CIST Role
1.3.6.1.4.1.4756.20.500.20.1.1426ColumnnidSTPPortStatusInst1CISTStateLocalread-onlycurrentNID Series card STP Port status: Instance1 - CIST State
1.3.6.1.4.1.4756.20.500.20.1.1427ColumnnidSTPPortStatusInst1UptimeLocalread-onlycurrentNID Series card STP Port status: Instance1 -Uptime
1.3.6.1.4.1.4756.20.500.20.1.1428ColumnnidSTPPortStatusInst2PortLocalread-onlycurrentNID Series card STP Port status: Instance2 - Port
1.3.6.1.4.1.4756.20.500.20.1.1429ColumnnidSTPPortStatusInst2CISTRoleLocalread-onlycurrentNID Series card STP Port status: Instance2 - CIST Role
1.3.6.1.4.1.4756.20.500.20.1.1430ColumnnidSTPPortStatusInst2CISTStateLocalread-onlycurrentNID Series card STP Port status: Instance2 - CIST State
1.3.6.1.4.1.4756.20.500.20.1.1431ColumnnidSTPPortStatusInst2UptimeLocalread-onlycurrentNID Series card STP Port status: Instance2 -Uptime
1.3.6.1.4.1.4756.20.500.20.1.1432ColumnnidSTPPortStatusInst3PortLocalread-onlycurrentNID Series card STP Port status: Instance3 - Port
1.3.6.1.4.1.4756.20.500.20.1.1433ColumnnidSTPPortStatusInst3CISTRoleLocalread-onlycurrentNID Series card STP Port status: Instance3 - CIST Role
1.3.6.1.4.1.4756.20.500.20.1.1434ColumnnidSTPPortStatusInst3CISTStateLocalread-onlycurrentNID Series card STP Port status: Instance3 - CIST State
1.3.6.1.4.1.4756.20.500.20.1.1435ColumnnidSTPPortStatusInst3UptimeLocalread-onlycurrentNID Series card STP Port status: Instance3 -Uptime
1.3.6.1.4.1.4756.20.500.20.1.1436ColumnnidSTPPortStatusInst4PortLocalread-onlycurrentNID Series card STP Port status: Instance4 - Port
1.3.6.1.4.1.4756.20.500.20.1.1437ColumnnidSTPPortStatusInst4CISTRoleLocalread-onlycurrentNID Series card STP Port status: Instance4 - CIST Role
1.3.6.1.4.1.4756.20.500.20.1.1438ColumnnidSTPPortStatusInst4CISTStateLocalread-onlycurrentNID Series card STP Port status: Instance4 - CIST State
1.3.6.1.4.1.4756.20.500.20.1.1439ColumnnidSTPPortStatusInst4UptimeLocalread-onlycurrentNID Series card STP Port status: Instance4 -Uptime
1.3.6.1.4.1.4756.20.500.20.1.1440ColumnnidSTPPortStatusInst5PortLocalread-onlycurrentNID Series card STP Port status: Instance5 - Port
1.3.6.1.4.1.4756.20.500.20.1.1441ColumnnidSTPPortStatusInst5CISTRoleLocalread-onlycurrentNID Series card STP Port status: Instance5 - CIST Role
1.3.6.1.4.1.4756.20.500.20.1.1442ColumnnidSTPPortStatusInst5CISTStateLocalread-onlycurrentNID Series card STP Port status: Instance5 - CIST State
1.3.6.1.4.1.4756.20.500.20.1.1443ColumnnidSTPPortStatusInst5UptimeLocalread-onlycurrentNID Series card STP Port status: Instance5 -Uptime
1.3.6.1.4.1.4756.20.500.20.1.1444ColumnnidSTPPortStatusInst6PortLocalread-onlycurrentNID Series card STP Port status: Instance6- Port
1.3.6.1.4.1.4756.20.500.20.1.1445ColumnnidSTPPortStatusInst6CISTRoleLocalread-onlycurrentNID Series card STP Port status: Instance6- CIST Role
1.3.6.1.4.1.4756.20.500.20.1.1446ColumnnidSTPPortStatusInst6CISTStateLocalread-onlycurrentNID Series card STP Port status: Instance6- CIST State
1.3.6.1.4.1.4756.20.500.20.1.1447ColumnnidSTPPortStatusInst6UptimeLocalread-onlycurrentNID Series card STP Port status: Instance6-Uptime
1.3.6.1.4.1.4756.20.500.20.1.1448ColumnnidSTPPortStatusInst7PortLocalread-onlycurrentNID Series card STP Port status: Instance7- Port
1.3.6.1.4.1.4756.20.500.20.1.1449ColumnnidSTPPortStatusInst7CISTRoleLocalread-onlycurrentNID Series card STP Port status: Instance7- CIST Role
1.3.6.1.4.1.4756.20.500.20.1.1450ColumnnidSTPPortStatusInst7CISTStateLocalread-onlycurrentNID Series card STP Port status: Instance7- CIST State
1.3.6.1.4.1.4756.20.500.20.1.1451ColumnnidSTPPortStatusInst7UptimeLocalread-onlycurrentNID Series card STP Port status: Instance7-Uptime
1.3.6.1.4.1.4756.20.500.20.1.1452ColumnnidSTPPortStatusInst8PortLocalread-onlycurrentNID Series card STP Port status: Instance8- Port
1.3.6.1.4.1.4756.20.500.20.1.1453ColumnnidSTPPortStatusInst8CISTRoleLocalread-onlycurrentNID Series card STP Port status: Instance8- CIST Role
1.3.6.1.4.1.4756.20.500.20.1.1454ColumnnidSTPPortStatusInst8CISTStateLocalread-onlycurrentNID Series card STP Port status: Instance8- CIST State
1.3.6.1.4.1.4756.20.500.20.1.1455ColumnnidSTPPortStatusInst8UptimeLocalread-onlycurrentNID Series card STP Port status: Instance8-Uptime
1.3.6.1.4.1.4756.20.500.20.1.1456ColumnnidSTPStatisticsPort1TxMSTPLocalread-onlycurrentNID Series card STP Port Statistics: Port1 -Transmitted MSTP
1.3.6.1.4.1.4756.20.500.20.1.1457ColumnnidSTPStatisticsPort1TxRSTPLocalread-onlycurrentNID Series card STP Port Statistics: Port1 -Transmitted RSTP
1.3.6.1.4.1.4756.20.500.20.1.1458ColumnnidSTPStatisticsPort1TxSTPLocalread-onlycurrentNID Series card STP Port Statistics: Port1 -Transmitted RSTP
1.3.6.1.4.1.4756.20.500.20.1.1459ColumnnidSTPStatisticsPort1TxTCNLocalread-onlycurrentNID Series card STP Port Statistics: Port1 -Transmitted RSTP
1.3.6.1.4.1.4756.20.500.20.1.1460ColumnnidSTPStatisticsPort1RxMSTPLocalread-onlycurrentNID Series card STP Port Statistics: Port1 -Received MSTP
1.3.6.1.4.1.4756.20.500.20.1.1461ColumnnidSTPStatisticsPort1RxRSTPLocalread-onlycurrentNID Series card STP Port Statistics: Port1 -Received RSTP
1.3.6.1.4.1.4756.20.500.20.1.1462ColumnnidSTPStatisticsPort1RxSTPLocalread-onlycurrentNID Series card STP Port Statistics: Port1 -Received RSTP
1.3.6.1.4.1.4756.20.500.20.1.1463ColumnnidSTPStatisticsPort1RxTCNLocalread-onlycurrentNID Series card STP Port Statistics: Port1 -Received RSTP
1.3.6.1.4.1.4756.20.500.20.1.1464ColumnnidSTPStatisticsPort1DiscardUnknowLocalread-onlycurrentNID Series card STP Port Statistics: Port1 -Discarded Unknown
1.3.6.1.4.1.4756.20.500.20.1.1465ColumnnidSTPStatisticsPort1DiscardIllegalLocalread-onlycurrentNID Series card STP Port Statistics: Port1 -Discarded Illegal
1.3.6.1.4.1.4756.20.500.20.1.1466ColumnnidSTPStatisticsPort2TxMSTPLocalread-onlycurrentNID Series card STP Port Statistics: Port2 -Transmitted MSTP
1.3.6.1.4.1.4756.20.500.20.1.1467ColumnnidSTPStatisticsPort2TxRSTPLocalread-onlycurrentNID Series card STP Port Statistics: Port2 -Transmitted RSTP
1.3.6.1.4.1.4756.20.500.20.1.1468ColumnnidSTPStatisticsPort2TxSTPLocalread-onlycurrentNID Series card STP Port Statistics: Port2 -Transmitted RSTP
1.3.6.1.4.1.4756.20.500.20.1.1469ColumnnidSTPStatisticsPort2TxTCNLocalread-onlycurrentNID Series card STP Port Statistics: Port2 -Transmitted RSTP
1.3.6.1.4.1.4756.20.500.20.1.1470ColumnnidSTPStatisticsPort2RxMSTPLocalread-onlycurrentNID Series card STP Port Statistics: Port2 -Received MSTP
1.3.6.1.4.1.4756.20.500.20.1.1471ColumnnidSTPStatisticsPort2RxRSTPLocalread-onlycurrentNID Series card STP Port Statistics: Port1 -Received RSTP
1.3.6.1.4.1.4756.20.500.20.1.1472ColumnnidSTPStatisticsPort2RxSTPLocalread-onlycurrentNID Series card STP Port Statistics: Port2 -Received RSTP
1.3.6.1.4.1.4756.20.500.20.1.1473ColumnnidSTPStatisticsPort2RxTCNLocalread-onlycurrentNID Series card STP Port Statistics: Port2 -Received RSTP
1.3.6.1.4.1.4756.20.500.20.1.1474ColumnnidSTPStatisticsPort2DiscardUnknowLocalread-onlycurrentNID Series card STP Port Statistics: Port2 -Discarded Unknown
1.3.6.1.4.1.4756.20.500.20.1.1475ColumnnidSTPStatisticsPort2DiscardIllegalLocalread-onlycurrentNID Series card STP Port Statistics: Port2 -Discarded Illegal
1.3.6.1.4.1.4756.20.500.20.1.1476ColumnnidSTPStatisticsPort3TxMSTPLocalread-onlycurrentNID Series card STP Port Statistics: Port3 -Transmitted MSTP
1.3.6.1.4.1.4756.20.500.20.1.1477ColumnnidSTPStatisticsPort3TxRSTPLocalread-onlycurrentNID Series card STP Port Statistics: Port3 -Transmitted RSTP
1.3.6.1.4.1.4756.20.500.20.1.1478ColumnnidSTPStatisticsPort3TxSTPLocalread-onlycurrentNID Series card STP Port Statistics: Port3 -Transmitted RSTP
1.3.6.1.4.1.4756.20.500.20.1.1479ColumnnidSTPStatisticsPort3TxTCNLocalread-onlycurrentNID Series card STP Port Statistics: Port3 -Transmitted RSTP
1.3.6.1.4.1.4756.20.500.20.1.1480ColumnnidSTPStatisticsPort3RxMSTPLocalread-onlycurrentNID Series card STP Port Statistics: Port3 -Received MSTP
1.3.6.1.4.1.4756.20.500.20.1.1481ColumnnidSTPStatisticsPort3RxRSTPLocalread-onlycurrentNID Series card STP Port Statistics: Port3 -Received RSTP
1.3.6.1.4.1.4756.20.500.20.1.1482ColumnnidSTPStatisticsPort3RxSTPLocalread-onlycurrentNID Series card STP Port Statistics: Port3 -Received RSTP
1.3.6.1.4.1.4756.20.500.20.1.1483ColumnnidSTPStatisticsPort3RxTCNLocalread-onlycurrentNID Series card STP Port Statistics: Port3 -Received RSTP
1.3.6.1.4.1.4756.20.500.20.1.1484ColumnnidSTPStatisticsPort3DiscardUnknowLocalread-onlycurrentNID Series card STP Port Statistics: Port3 -Discarded Unknown
1.3.6.1.4.1.4756.20.500.20.1.1485ColumnnidSTPStatisticsPort3DiscardIllegalLocalread-onlycurrentNID Series card STP Port Statistics: Port3 -Discarded Illegal
1.3.6.1.4.1.4756.20.500.20.1.1486ColumnnidSTPStatisticsPort4TxMSTPLocalread-onlycurrentNID Series card STP Port Statistics: Port4 -Transmitted MSTP
1.3.6.1.4.1.4756.20.500.20.1.1487ColumnnidSTPStatisticsPort4TxRSTPLocalread-onlycurrentNID Series card STP Port Statistics: Port4 -Transmitted RSTP
1.3.6.1.4.1.4756.20.500.20.1.1488ColumnnidSTPStatisticsPort4TxSTPLocalread-onlycurrentNID Series card STP Port Statistics: Port4 -Transmitted RSTP
1.3.6.1.4.1.4756.20.500.20.1.1489ColumnnidSTPStatisticsPort4TxTCNLocalread-onlycurrentNID Series card STP Port Statistics: Port4 -Transmitted RSTP
1.3.6.1.4.1.4756.20.500.20.1.1490ColumnnidSTPStatisticsPort4RxMSTPLocalread-onlycurrentNID Series card STP Port Statistics: Port4 -Received MSTP
1.3.6.1.4.1.4756.20.500.20.1.1491ColumnnidSTPStatisticsPort4RxRSTPLocalread-onlycurrentNID Series card STP Port Statistics: Port4 -Received RSTP
1.3.6.1.4.1.4756.20.500.20.1.1492ColumnnidSTPStatisticsPort4RxSTPLocalread-onlycurrentNID Series card STP Port Statistics: Port4 -Received RSTP
1.3.6.1.4.1.4756.20.500.20.1.1493ColumnnidSTPStatisticsPort4RxTCNLocalread-onlycurrentNID Series card STP Port Statistics: Port4 -Received RSTP
1.3.6.1.4.1.4756.20.500.20.1.1494ColumnnidSTPStatisticsPort4DiscardUnknowLocalread-onlycurrentNID Series card STP Port Statistics: Port4 -Discarded Unknown
1.3.6.1.4.1.4756.20.500.20.1.1495ColumnnidSTPStatisticsPort4DiscardIllegalLocalread-onlycurrentNID Series card STP Port Statistics: Port4 -Discarded Illegal
1.3.6.1.4.1.4756.20.500.20.1.1496ColumnnidSTPStatisticsPort5TxMSTPLocalread-onlycurrentNID Series card STP Port Statistics: Port5 -Transmitted MSTP
1.3.6.1.4.1.4756.20.500.20.1.1497ColumnnidSTPStatisticsPort5TxRSTPLocalread-onlycurrentNID Series card STP Port Statistics: Port5 -Transmitted RSTP
1.3.6.1.4.1.4756.20.500.20.1.1498ColumnnidSTPStatisticsPort5TxSTPLocalread-onlycurrentNID Series card STP Port Statistics: Port5 -Transmitted RSTP
1.3.6.1.4.1.4756.20.500.20.1.1499ColumnnidSTPStatisticsPort5TxTCNLocalread-onlycurrentNID Series card STP Port Statistics: Port5 -Transmitted RSTP
1.3.6.1.4.1.4756.20.500.20.1.1500ColumnnidSTPStatisticsPort5RxMSTPLocalread-onlycurrentNID Series card STP Port Statistics: Port5 -Received MSTP
1.3.6.1.4.1.4756.20.500.20.1.1501ColumnnidSTPStatisticsPort5RxRSTPLocalread-onlycurrentNID Series card STP Port Statistics: Port5 -Received RSTP
1.3.6.1.4.1.4756.20.500.20.1.1502ColumnnidSTPStatisticsPort5RxSTPLocalread-onlycurrentNID Series card STP Port Statistics: Port5 -Received RSTP
1.3.6.1.4.1.4756.20.500.20.1.1503ColumnnidSTPStatisticsPort5RxTCNLocalread-onlycurrentNID Series card STP Port Statistics: Port5 -Received RSTP
1.3.6.1.4.1.4756.20.500.20.1.1504ColumnnidSTPStatisticsPort5DiscardUnknowLocalread-onlycurrentNID Series card STP Port Statistics: Port5 -Discarded Unknown
1.3.6.1.4.1.4756.20.500.20.1.1505ColumnnidSTPStatisticsPort5DiscardIllegalLocalread-onlycurrentNID Series card STP Port Statistics: Port5 -Discarded Illegal
1.3.6.1.4.1.4756.20.500.20.1.1506ColumnnidSTPStatisticsPort6TxMSTPLocalread-onlycurrentNID Series card STP Port Statistics: Port6 -Transmitted MSTP
1.3.6.1.4.1.4756.20.500.20.1.1507ColumnnidSTPStatisticsPort6TxRSTPLocalread-onlycurrentNID Series card STP Port Statistics: Port6 -Transmitted RSTP
1.3.6.1.4.1.4756.20.500.20.1.1508ColumnnidSTPStatisticsPort6TxSTPLocalread-onlycurrentNID Series card STP Port Statistics: Port6 -Transmitted RSTP
1.3.6.1.4.1.4756.20.500.20.1.1509ColumnnidSTPStatisticsPort6TxTCNLocalread-onlycurrentNID Series card STP Port Statistics: Port6 -Transmitted RSTP
1.3.6.1.4.1.4756.20.500.20.1.1510ColumnnidSTPStatisticsPort6RxMSTPLocalread-onlycurrentNID Series card STP Port Statistics: Port6 -Received MSTP
1.3.6.1.4.1.4756.20.500.20.1.1511ColumnnidSTPStatisticsPort6RxRSTPLocalread-onlycurrentNID Series card STP Port Statistics: Port6 -Received RSTP
1.3.6.1.4.1.4756.20.500.20.1.1512ColumnnidSTPStatisticsPort6RxSTPLocalread-onlycurrentNID Series card STP Port Statistics: Port6 -Received RSTP
1.3.6.1.4.1.4756.20.500.20.1.1513ColumnnidSTPStatisticsPort6RxTCNLocalread-onlycurrentNID Series card STP Port Statistics: Port6 -Received RSTP
1.3.6.1.4.1.4756.20.500.20.1.1514ColumnnidSTPStatisticsPort6DiscardUnknowLocalread-onlycurrentNID Series card STP Port Statistics: Port6 -Discarded Unknown
1.3.6.1.4.1.4756.20.500.20.1.1515ColumnnidSTPStatisticsPort6DiscardIllegalLocalread-onlycurrentNID Series card STP Port Statistics: Port6 -Discarded Illegal
1.3.6.1.4.1.4756.20.500.20.1.1516ColumnnidSTPStatisticsPort7TxMSTPLocalread-onlycurrentNID Series card STP Port Statistics: Port7 -Transmitted MSTP
1.3.6.1.4.1.4756.20.500.20.1.1517ColumnnidSTPStatisticsPort7TxRSTPLocalread-onlycurrentNID Series card STP Port Statistics: Port7 -Transmitted RSTP
1.3.6.1.4.1.4756.20.500.20.1.1518ColumnnidSTPStatisticsPort7TxSTPLocalread-onlycurrentNID Series card STP Port Statistics: Port7 -Transmitted RSTP
1.3.6.1.4.1.4756.20.500.20.1.1519ColumnnidSTPStatisticsPort7TxTCNLocalread-onlycurrentNID Series card STP Port Statistics: Port7 -Transmitted RSTP
1.3.6.1.4.1.4756.20.500.20.1.1520ColumnnidSTPStatisticsPort7RxMSTPLocalread-onlycurrentNID Series card STP Port Statistics: Port7 -Received MSTP
1.3.6.1.4.1.4756.20.500.20.1.1521ColumnnidSTPStatisticsPort7RxRSTPLocalread-onlycurrentNID Series card STP Port Statistics: Port7 -Received RSTP
1.3.6.1.4.1.4756.20.500.20.1.1522ColumnnidSTPStatisticsPort7RxSTPLocalread-onlycurrentNID Series card STP Port Statistics: Port7 -Received RSTP
1.3.6.1.4.1.4756.20.500.20.1.1523ColumnnidSTPStatisticsPort7RxTCNLocalread-onlycurrentNID Series card STP Port Statistics: Port7 -Received RSTP
1.3.6.1.4.1.4756.20.500.20.1.1524ColumnnidSTPStatisticsPort7DiscardUnknowLocalread-onlycurrentNID Series card STP Port Statistics: Port7 -Discarded Unknown
1.3.6.1.4.1.4756.20.500.20.1.1525ColumnnidSTPStatisticsPort7DiscardIllegalLocalread-onlycurrentNID Series card STP Port Statistics: Port7 -Discarded Illegal
1.3.6.1.4.1.4756.20.500.20.1.1526ColumnnidSTPStatisticsPort8TxMSTPLocalread-onlycurrentNID Series card STP Port Statistics: Port8 -Transmitted MSTP
1.3.6.1.4.1.4756.20.500.20.1.1527ColumnnidSTPStatisticsPort8TxRSTPLocalread-onlycurrentNID Series card STP Port Statistics: Port8 -Transmitted RSTP
1.3.6.1.4.1.4756.20.500.20.1.1528ColumnnidSTPStatisticsPort8TxSTPLocalread-onlycurrentNID Series card STP Port Statistics: Port8 -Transmitted RSTP
1.3.6.1.4.1.4756.20.500.20.1.1529ColumnnidSTPStatisticsPort8TxTCNLocalread-onlycurrentNID Series card STP Port Statistics: Port8 -Transmitted RSTP
1.3.6.1.4.1.4756.20.500.20.1.1530ColumnnidSTPStatisticsPort8RxMSTPLocalread-onlycurrentNID Series card STP Port Statistics: Port8 -Received MSTP
1.3.6.1.4.1.4756.20.500.20.1.1531ColumnnidSTPStatisticsPort8RxRSTPLocalread-onlycurrentNID Series card STP Port Statistics: Port8 -Received RSTP
1.3.6.1.4.1.4756.20.500.20.1.1532ColumnnidSTPStatisticsPort8RxSTPLocalread-onlycurrentNID Series card STP Port Statistics: Port8 -Received RSTP
1.3.6.1.4.1.4756.20.500.20.1.1533ColumnnidSTPStatisticsPort8RxTCNLocalread-onlycurrentNID Series card STP Port Statistics: Port8 -Received RSTP
1.3.6.1.4.1.4756.20.500.20.1.1534ColumnnidSTPStatisticsPort8DiscardUnknowLocalread-onlycurrentNID Series card STP Port Statistics: Port8 -Discarded Unknown
1.3.6.1.4.1.4756.20.500.20.1.1535ColumnnidSTPStatisticsPort8DiscardIllegalLocalread-onlycurrentNID Series card STP Port Statistics: Port8 -Discarded Illegal
1.3.6.1.4.1.4756.20.500.20.1.1536ColumnnidAllowedAccessVLANsLocalread-writecurrentNID Series card Global VLAN Configuration: Allowed Access VLANs By default, only VLAN 1 is enabled. More VLANs may be created by using a list syntax where the …
1.3.6.1.4.1.4756.20.500.20.1.1537ColumnnidVlanEthertypeLocalread-writecurrentNID Series card Global VLAN Configuration: Ethertype for Custom S-ports The format of 'Ethernet Type' is restricted to 0x600-0xFFFF
1.3.6.1.4.1.4756.20.500.20.1.1538ColumnnidPort1VlanModeLocalread-writecurrentNID Series card Port VLAN Configuration : Port1 - Mode 0: Access 1: Trunk 2: Hybrid
1.3.6.1.4.1.4756.20.500.20.1.1539ColumnnidPort1VlanIDLocalread-writecurrentNID Series card Port VLAN Configuration : Port1 - VLAN ID
1.3.6.1.4.1.4756.20.500.20.1.1540ColumnnidPort1VlanTypeLocalread-writecurrentNID Series card Port VLAN Configuration : Port1 - VLAN Type 0: Unaware 1: C-port 2: S-port 3: S-custom-port
1.3.6.1.4.1.4756.20.500.20.1.1541ColumnnidPort1VlanIngressFilteringLocalread-writecurrentNID Series card Port VLAN Configuration : Port1 - Ingress Filtering 0: Off 1: On
1.3.6.1.4.1.4756.20.500.20.1.1542ColumnnidPort1VlanIngressAcceptanceLocalread-writecurrentNID Series card Port VLAN Configuration : Port1 - Ingress Acceptance 0: Tagged and untagged 1: Tagged only 2: Untagged only
1.3.6.1.4.1.4756.20.500.20.1.1543ColumnnidPort1VlanEgressTaggingLocalread-writecurrentNID Series card Port VLAN Configuration : Port1 - Egress Tagging 0: Untag port vlan 1: Tag all 2: Untag all
1.3.6.1.4.1.4756.20.500.20.1.1544ColumnnidPort1AllowedVLANSLocalread-writecurrentNID Series card Global VLAN Configuration: Port1 - Allowed VLANs By default, only VLAN 1 is enabled. More VLANs may be created by using a list syntax where the…
1.3.6.1.4.1.4756.20.500.20.1.1545ColumnnidPort1ForbiddenVLANSLocalread-writecurrentNID Series card Global VLAN Configuration: Port1 - Forbidden VLANs By default, the field is left blank, which means that the port may become a member of all po…
1.3.6.1.4.1.4756.20.500.20.1.1546ColumnnidPort2VlanModeLocalread-writecurrentNID Series card Port VLAN Configuration : Port2 - Mode 0: Access 1: Trunk 2: Hybrid
1.3.6.1.4.1.4756.20.500.20.1.1547ColumnnidPort2VlanIDLocalread-writecurrentNID Series card Port VLAN Configuration : Port2 - VLAN ID
1.3.6.1.4.1.4756.20.500.20.1.1548ColumnnidPort2VlanTypeLocalread-writecurrentNID Series card Port VLAN Configuration : Port2 - VLAN Type 0: Unaware 1: C-port 2: S-port 3: S-custom-port
1.3.6.1.4.1.4756.20.500.20.1.1549ColumnnidPort2VlanIngressFilteringLocalread-writecurrentNID Series card Port VLAN Configuration : Port2 - Ingress Filtering 0: Off 1: On
1.3.6.1.4.1.4756.20.500.20.1.1550ColumnnidPort2VlanIngressAcceptanceLocalread-writecurrentNID Series card Port VLAN Configuration : Por2 - Ingress Acceptance 0: Tagged and untagged 1: Tagged only 2: Untagged only
1.3.6.1.4.1.4756.20.500.20.1.1551ColumnnidPort2VlanEgressTaggingLocalread-writecurrentNID Series card Port VLAN Configuration : Port2 - Egress Tagging 0: Untag port vlan 1: Tag all 2: Untag all
1.3.6.1.4.1.4756.20.500.20.1.1552ColumnnidPort2AllowedVLANSLocalread-writecurrentNID Series card Global VLAN Configuration: Port2 - Allowed VLANs By default, only VLAN 1 is enabled. More VLANs may be created by using a list syntax where the…
1.3.6.1.4.1.4756.20.500.20.1.1553ColumnnidPort2ForbiddenVLANSLocalread-writecurrentNID Series card Global VLAN Configuration: Port2 - Forbidden VLANs By default, the field is left blank, which means that the port may become a member of all po…
1.3.6.1.4.1.4756.20.500.20.1.1554ColumnnidPort3VlanModeLocalread-writecurrentNID Series card Port VLAN Configuration : Port3 - Mode 0: Access 1: Trunk 2: Hybrid
1.3.6.1.4.1.4756.20.500.20.1.1555ColumnnidPort3VlanIDLocalread-writecurrentNID Series card Port VLAN Configuration : Port3 - VLAN ID
1.3.6.1.4.1.4756.20.500.20.1.1556ColumnnidPort3VlanTypeLocalread-writecurrentNID Series card Port VLAN Configuration : Port3 - VLAN Type 0: Unaware 1: C-port 2: S-port 3: S-custom-port
1.3.6.1.4.1.4756.20.500.20.1.1557ColumnnidPort3VlanIngressFilteringLocalread-writecurrentNID Series card Port VLAN Configuration : Port3 - Ingress Filtering 0: Off 1: On
1.3.6.1.4.1.4756.20.500.20.1.1558ColumnnidPort3VlanIngressAcceptanceLocalread-writecurrentNID Series card Port VLAN Configuration : Port3 - Ingress Acceptance 0: Tagged and untagged 1: Tagged only 2: Untagged only
1.3.6.1.4.1.4756.20.500.20.1.1559ColumnnidPort3VlanEgressTaggingLocalread-writecurrentNID Series card Port VLAN Configuration : Port3 - Egress Tagging 0: Untag port vlan 1: Tag all 2: Untag all
1.3.6.1.4.1.4756.20.500.20.1.1560ColumnnidPort3AllowedVLANSLocalread-writecurrentNID Series card Global VLAN Configuration: Port3 - Allowed VLANs By default, only VLAN 1 is enabled. More VLANs may be created by using a list syntax where the…
1.3.6.1.4.1.4756.20.500.20.1.1561ColumnnidPort3ForbiddenVLANSLocalread-writecurrentNID Series card Global VLAN Configuration: Port3 - Forbidden VLANs By default, the field is left blank, which means that the port may become a member of all po…
1.3.6.1.4.1.4756.20.500.20.1.1562ColumnnidPort4VlanModeLocalread-writecurrentNID Series card Port VLAN Configuration : Port4 - Mode 0: Access 1: Trunk 2: Hybrid
1.3.6.1.4.1.4756.20.500.20.1.1563ColumnnidPort4VlanIDLocalread-writecurrentNID Series card Port VLAN Configuration : Port4 - VLAN ID
1.3.6.1.4.1.4756.20.500.20.1.1564ColumnnidPort4VlanTypeLocalread-writecurrentNID Series card Port VLAN Configuration : Port4 - VLAN Type 0: Unaware 1: C-port 2: S-port 3: S-custom-port
1.3.6.1.4.1.4756.20.500.20.1.1565ColumnnidPort4VlanIngressFilteringLocalread-writecurrentNID Series card Port VLAN Configuration : Port4 - Ingress Filtering 0: Off 1: On
1.3.6.1.4.1.4756.20.500.20.1.1566ColumnnidPort4VlanIngressAcceptanceLocalread-writecurrentNID Series card Port VLAN Configuration : Port4 - Ingress Acceptance 0: Tagged and untagged 1: Tagged only 2: Untagged only
1.3.6.1.4.1.4756.20.500.20.1.1567ColumnnidPort4VlanEgressTaggingLocalread-writecurrentNID Series card Port VLAN Configuration : Port4 - Egress Tagging 0: Untag port vlan 1: Tag all 2: Untag all
1.3.6.1.4.1.4756.20.500.20.1.1568ColumnnidPort4AllowedVLANSLocalread-writecurrentNID Series card Global VLAN Configuration: Port4 - Allowed VLANs By default, only VLAN 1 is enabled. More VLANs may be created by using a list syntax where the…
1.3.6.1.4.1.4756.20.500.20.1.1569ColumnnidPort4ForbiddenVLANSLocalread-writecurrentNID Series card Global VLAN Configuration: Port4 - Forbidden VLANs By default, the field is left blank, which means that the port may become a member of all po…
1.3.6.1.4.1.4756.20.500.20.1.1570ColumnnidPort5VlanModeLocalread-writecurrentNID Series card Port VLAN Configuration : Port5 - Mode 0: Access 1: Trunk 2: Hybrid
1.3.6.1.4.1.4756.20.500.20.1.1571ColumnnidPort5VlanIDLocalread-writecurrentNID Series card Port VLAN Configuration : Port5 - VLAN ID
1.3.6.1.4.1.4756.20.500.20.1.1572ColumnnidPort5VlanTypeLocalread-writecurrentNID Series card Port VLAN Configuration : Port5 - VLAN Type 0: Unaware 1: C-port 2: S-port 3: S-custom-port
1.3.6.1.4.1.4756.20.500.20.1.1573ColumnnidPort5VlanIngressFilteringLocalread-writecurrentNID Series card Port VLAN Configuration : Port5 - Ingress Filtering 0: Off 1: On
1.3.6.1.4.1.4756.20.500.20.1.1574ColumnnidPort5VlanIngressAcceptanceLocalread-writecurrentNID Series card Port VLAN Configuration : Port5 - Ingress Acceptance 0: Tagged and untagged 1: Tagged only 2: Untagged only
1.3.6.1.4.1.4756.20.500.20.1.1575ColumnnidPort5VlanEgressTaggingLocalread-writecurrentNID Series card Port VLAN Configuration : Port5 - Egress Tagging 0: Untag port vlan 1: Tag all 2: Untag all
1.3.6.1.4.1.4756.20.500.20.1.1576ColumnnidPort5AllowedVLANSLocalread-writecurrentNID Series card Global VLAN Configuration: Port5 - Allowed VLANs By default, only VLAN 1 is enabled. More VLANs may be created by using a list syntax where the…
1.3.6.1.4.1.4756.20.500.20.1.1577ColumnnidPort5ForbiddenVLANSLocalread-writecurrentNID Series card Global VLAN Configuration: Port5 - Forbidden VLANs By default, the field is left blank, which means that the port may become a member of all po…
1.3.6.1.4.1.4756.20.500.20.1.1578ColumnnidPort6VlanModeLocalread-writecurrentNID Series card Port VLAN Configuration : Port6 - Mode 0: Access 1: Trunk 2: Hybrid
1.3.6.1.4.1.4756.20.500.20.1.1579ColumnnidPort6VlanIDLocalread-writecurrentNID Series card Port VLAN Configuration : Port6 - VLAN ID
1.3.6.1.4.1.4756.20.500.20.1.1580ColumnnidPort6VlanTypeLocalread-writecurrentNID Series card Port VLAN Configuration : Port6 - VLAN Type 0: Unaware 1: C-port 2: S-port 3: S-custom-port
1.3.6.1.4.1.4756.20.500.20.1.1581ColumnnidPort6VlanIngressFilteringLocalread-writecurrentNID Series card Port VLAN Configuration : Port6 - Ingress Filtering 0: Off 1: On
1.3.6.1.4.1.4756.20.500.20.1.1582ColumnnidPort6VlanIngressAcceptanceLocalread-writecurrentNID Series card Port VLAN Configuration : Port6 - Ingress Acceptance 0: Tagged and untagged 1: Tagged only 2: Untagged only
1.3.6.1.4.1.4756.20.500.20.1.1583ColumnnidPort6VlanEgressTaggingLocalread-writecurrentNID Series card Port VLAN Configuration : Port6 - Egress Tagging 0: Untag port vlan 1: Tag all 2: Untag all
1.3.6.1.4.1.4756.20.500.20.1.1584ColumnnidPort6AllowedVLANSLocalread-writecurrentNID Series card Global VLAN Configuration: Port6 - Allowed VLANs By default, only VLAN 1 is enabled. More VLANs may be created by using a list syntax where the…
1.3.6.1.4.1.4756.20.500.20.1.1585ColumnnidPort6ForbiddenVLANSLocalread-writecurrentNID Series card Global VLAN Configuration: Port6 - Forbidden VLANs By default, the field is left blank, which means that the port may become a member of all po…
1.3.6.1.4.1.4756.20.500.20.1.1586ColumnnidPort7VlanModeLocalread-writecurrentNID Series card Port VLAN Configuration : Port7 - Mode 0: Access 1: Trunk 2: Hybrid
1.3.6.1.4.1.4756.20.500.20.1.1587ColumnnidPort7VlanIDLocalread-writecurrentNID Series card Port VLAN Configuration : Port7 - VLAN ID
1.3.6.1.4.1.4756.20.500.20.1.1588ColumnnidPort7VlanTypeLocalread-writecurrentNID Series card Port VLAN Configuration : Port7 - VLAN Type 0: Unaware 1: C-port 2: S-port 3: S-custom-port
1.3.6.1.4.1.4756.20.500.20.1.1589ColumnnidPort7VlanIngressFilteringLocalread-writecurrentNID Series card Port VLAN Configuration : Port7 - Ingress Filtering 0: Off 1: On
1.3.6.1.4.1.4756.20.500.20.1.1590ColumnnidPort7VlanIngressAcceptanceLocalread-writecurrentNID Series card Port VLAN Configuration : Port7 - Ingress Acceptance 0: Tagged and untagged 1: Tagged only 2: Untagged only
1.3.6.1.4.1.4756.20.500.20.1.1591ColumnnidPort7VlanEgressTaggingLocalread-writecurrentNID Series card Port VLAN Configuration : Port7 - Egress Tagging 0: Untag port vlan 1: Tag all 2: Untag all
1.3.6.1.4.1.4756.20.500.20.1.1592ColumnnidPort7AllowedVLANSLocalread-writecurrentNID Series card Global VLAN Configuration: Port7 - Allowed VLANs By default, only VLAN 1 is enabled. More VLANs may be created by using a list syntax where the…
1.3.6.1.4.1.4756.20.500.20.1.1593ColumnnidPort7ForbiddenVLANSLocalread-writecurrentNID Series card Global VLAN Configuration: Port7 - Forbidden VLANs By default, the field is left blank, which means that the port may become a member of all po…
1.3.6.1.4.1.4756.20.500.20.1.1594ColumnnidPort8VlanModeLocalread-writecurrentNID Series card Port VLAN Configuration : Port8 - Mode 0: Access 1: Trunk 2: Hybrid
1.3.6.1.4.1.4756.20.500.20.1.1595ColumnnidPort8VlanIDLocalread-writecurrentNID Series card Port VLAN Configuration : Port8 - VLAN ID
1.3.6.1.4.1.4756.20.500.20.1.1596ColumnnidPort8VlanTypeLocalread-writecurrentNID Series card Port VLAN Configuration : Port8 - VLAN Type 0: Unaware 1: C-port 2: S-port 3: S-custom-port
1.3.6.1.4.1.4756.20.500.20.1.1597ColumnnidPort8VlanIngressFilteringLocalread-writecurrentNID Series card Port VLAN Configuration : Port8 - Ingress Filtering 0: Off 1: On
1.3.6.1.4.1.4756.20.500.20.1.1598ColumnnidPort8VlanIngressAcceptanceLocalread-writecurrentNID Series card Port VLAN Configuration : Port8 - Ingress Acceptance 0: Tagged and untagged 1: Tagged only 2: Untagged only
1.3.6.1.4.1.4756.20.500.20.1.1599ColumnnidPort8VlanEgressTaggingLocalread-writecurrentNID Series card Port VLAN Configuration : Port8 - Egress Tagging 0: Untag port vlan 1: Tag all 2: Untag all
1.3.6.1.4.1.4756.20.500.20.1.1600ColumnnidPort8AllowedVLANSLocalread-writecurrentNID Series card Global VLAN Configuration: Port8 - Allowed VLANs By default, only VLAN 1 is enabled. More VLANs may be created by using a list syntax where the…
1.3.6.1.4.1.4756.20.500.20.1.1601ColumnnidPort8ForbiddenVLANSLocalread-writecurrentNID Series card Global VLAN Configuration: Port8 - Forbidden VLANs By default, the field is left blank, which means that the port may become a member of all po…
1.3.6.1.4.1.4756.20.500.20.1.1602ColumnnidQOSPort1IngressLocalread-writecurrentNID Series card QOS Port1 Ingress Enabled 0: NO 1: YES
1.3.6.1.4.1.4756.20.500.20.1.1603ColumnnidQOSPort1IngressRateLocalread-writecurrentNID Series card QOS Port1 Ingress Rate
1.3.6.1.4.1.4756.20.500.20.1.1604ColumnnidQOSPort1IngressRateUnitLocalread-writecurrentNID Series card QOS Port1 Ingress Rate Unit 0: Kbps 1: Mbps 2: fps 3: kfps
1.3.6.1.4.1.4756.20.500.20.1.1605ColumnnidQOSPort1IngressFlowControlLocalread-writecurrentNID Series card QOS Port1 Ingress Flow Control 0: NO 1: YES
1.3.6.1.4.1.4756.20.500.20.1.1606ColumnnidQOSPort2IngressLocalread-writecurrentNID Series card QOS Port2 Ingress Enabled 0: NO 1: YES
1.3.6.1.4.1.4756.20.500.20.1.1607ColumnnidQOSPort2IngressRateLocalread-writecurrentNID Series card QOS Port2 Ingress Rate
1.3.6.1.4.1.4756.20.500.20.1.1608ColumnnidQOSPort2IngressRateUnitLocalread-writecurrentNID Series card QOS Port2 Ingress Rate Unit 0: Kbps 1: Mbps 2: fps 3: kfps
1.3.6.1.4.1.4756.20.500.20.1.1609ColumnnidQOSPort2IngressFlowControlLocalread-writecurrentNID Series card QOS Port2 Ingress Flow Control 0: NO 1: YES
1.3.6.1.4.1.4756.20.500.20.1.1610ColumnnidQOSPort3IngressLocalread-writecurrentNID Series card QOS Port3 Ingress Enabled 0: NO 1: YES
1.3.6.1.4.1.4756.20.500.20.1.1611ColumnnidQOSPort3IngressRateLocalread-writecurrentNID Series card QOS Port3 Ingress Rate
1.3.6.1.4.1.4756.20.500.20.1.1612ColumnnidQOSPort3IngressRateUnitLocalread-writecurrentNID Series card QOS Port3 Ingress Rate Unit 0: Kbps 1: Mbps 2: fps 3: kfps
1.3.6.1.4.1.4756.20.500.20.1.1613ColumnnidQOSPort3IngressFlowControlLocalread-writecurrentNID Series card QOS Port3 Ingress Flow Control 0: NO 1: YES
1.3.6.1.4.1.4756.20.500.20.1.1614ColumnnidQOSPort4IngressLocalread-writecurrentNID Series card QOS Port4 Ingress Enabled 0: NO 1: YES
1.3.6.1.4.1.4756.20.500.20.1.1615ColumnnidQOSPort4IngressRateLocalread-writecurrentNID Series card QOS Port4 Ingress Rate
1.3.6.1.4.1.4756.20.500.20.1.1616ColumnnidQOSPort4IngressRateUnitLocalread-writecurrentNID Series card QOS Port4 Ingress Rate Unit 0: Kbps 1: Mbps 2: fps 3: kfps
1.3.6.1.4.1.4756.20.500.20.1.1617ColumnnidQOSPort4IngressFlowControlLocalread-writecurrentNID Series card QOS Port4 Ingress Flow Control 0: NO 1: YES
1.3.6.1.4.1.4756.20.500.20.1.1618ColumnnidQOSPort5IngressLocalread-writecurrentNID Series card QOS Port5 Ingress Enabled 0: NO 1: YES
1.3.6.1.4.1.4756.20.500.20.1.1619ColumnnidQOSPort5IngressRateLocalread-writecurrentNID Series card QOS Port5 Ingress Rate
1.3.6.1.4.1.4756.20.500.20.1.1620ColumnnidQOSPort5IngressRateUnitLocalread-writecurrentNID Series card QOS Port5 Ingress Rate Unit 0: Kbps 1: Mbps 2: fps 3: kfps
1.3.6.1.4.1.4756.20.500.20.1.1621ColumnnidQOSPort5IngressFlowControlLocalread-writecurrentNID Series card QOS Port5 Ingress Flow Control 0: NO 1: YES
1.3.6.1.4.1.4756.20.500.20.1.1622ColumnnidQOSPort6IngressLocalread-writecurrentNID Series card QOS Port6 Ingress Enabled 0: NO 1: YES
1.3.6.1.4.1.4756.20.500.20.1.1623ColumnnidQOSPort6IngressRateLocalread-writecurrentNID Series card QOS Port6 Ingress Rate
1.3.6.1.4.1.4756.20.500.20.1.1624ColumnnidQOSPort6IngressRateUnitLocalread-writecurrentNID Series card QOS Port6 Ingress Rate Unit 0: Kbps 1: Mbps 2: fps 3: kfps
1.3.6.1.4.1.4756.20.500.20.1.1625ColumnnidQOSPort6IngressFlowControlLocalread-writecurrentNID Series card QOS Port6 Ingress Flow Control 0: NO 1: YES
1.3.6.1.4.1.4756.20.500.20.1.1626ColumnnidQOSPort7IngressLocalread-writecurrentNID Series card QOS Port7 Ingress Enabled 0: NO 1: YES
1.3.6.1.4.1.4756.20.500.20.1.1627ColumnnidQOSPort7IngressRateLocalread-writecurrentNID Series card QOS Port7 Ingress Rate
1.3.6.1.4.1.4756.20.500.20.1.1628ColumnnidQOSPort7IngressRateUnitLocalread-writecurrentNID Series card QOS Port7 Ingress Rate Unit 0: Kbps 1: Mbps 2: fps 3: kfps
1.3.6.1.4.1.4756.20.500.20.1.1629ColumnnidQOSPort7IngressFlowControlLocalread-writecurrentNID Series card QOS Port7 Ingress Flow Control 0: NO 1: YES
1.3.6.1.4.1.4756.20.500.20.1.1630ColumnnidQOSPort8IngressLocalread-writecurrentNID Series card QOS Port8 Ingress Enabled 0: NO 1: YES
1.3.6.1.4.1.4756.20.500.20.1.1631ColumnnidQOSPort8IngressRateLocalread-writecurrentNID Series card QOS Port8 Ingress Rate
1.3.6.1.4.1.4756.20.500.20.1.1632ColumnnidQOSPort8IngressRateUnitLocalread-writecurrentNID Series card QOS Port8 Ingress Rate Unit 0: Kbps 1: Mbps 2: fps 3: kfps
1.3.6.1.4.1.4756.20.500.20.1.1633ColumnnidQOSPort8IngressFlowControlLocalread-writecurrentNID Series card QOS Port8 Ingress Flow Control 0: NO 1: YES
1.3.6.1.4.1.4756.20.500.20.1.1634ColumnnidQOSPort1EgressLocalread-writecurrentNID Series card QOS Port1 Egress Enabled 0: NO 1: YES
1.3.6.1.4.1.4756.20.500.20.1.1635ColumnnidQOSPort1EgressRateLocalread-writecurrentNID Series card QOS Port1 Egress Rate
1.3.6.1.4.1.4756.20.500.20.1.1636ColumnnidQOSPort1EgressRateUnitLocalread-writecurrentNID Series card QOS Port1 Egress Rate Unit 0: Kbps 1: Mbps
1.3.6.1.4.1.4756.20.500.20.1.1637ColumnnidQOSPort2EgressLocalread-writecurrentNID Series card QOS Port2 Egress Enabled 0: NO 1: YES
1.3.6.1.4.1.4756.20.500.20.1.1638ColumnnidQOSPort2EgressRateLocalread-writecurrentNID Series card QOS Port2 Egress Rate
1.3.6.1.4.1.4756.20.500.20.1.1639ColumnnidQOSPort2EgressRateUnitLocalread-writecurrentNID Series card QOS Port2 Egress Rate Unit 0: Kbps 1: Mbps
1.3.6.1.4.1.4756.20.500.20.1.1640ColumnnidQOSPort3EgressLocalread-writecurrentNID Series card QOS Port3 Egress Enabled 0: NO 1: YES
1.3.6.1.4.1.4756.20.500.20.1.1641ColumnnidQOSPort3EgressRateLocalread-writecurrentNID Series card QOS Port3 Egress Rate
1.3.6.1.4.1.4756.20.500.20.1.1642ColumnnidQOSPort3EgressRateUnitLocalread-writecurrentNID Series card QOS Port3 Egress Rate Unit 0: Kbps 1: Mbps
1.3.6.1.4.1.4756.20.500.20.1.1643ColumnnidQOSPort4EgressLocalread-writecurrentNID Series card QOS Port4 Egress Enabled 0: NO 1: YES
1.3.6.1.4.1.4756.20.500.20.1.1644ColumnnidQOSPort4EgressRateLocalread-writecurrentNID Series card QOS Port4 Egress Rate
1.3.6.1.4.1.4756.20.500.20.1.1645ColumnnidQOSPort4EgressRateUnitLocalread-writecurrentNID Series card QOS Port4 Egress Rate Unit 0: Kbps 1: Mbps
1.3.6.1.4.1.4756.20.500.20.1.1646ColumnnidQOSPort5EgressLocalread-writecurrentNID Series card QOS Port5 Egress Enabled 0: NO 1: YES
1.3.6.1.4.1.4756.20.500.20.1.1647ColumnnidQOSPort5EgressRateLocalread-writecurrentNID Series card QOS Port5 Egress Rate
1.3.6.1.4.1.4756.20.500.20.1.1648ColumnnidQOSPort5EgressRateUnitLocalread-writecurrentNID Series card QOS Port5 Egress Rate Unit 0: Kbps 1: Mbps
1.3.6.1.4.1.4756.20.500.20.1.1649ColumnnidQOSPort6EgressLocalread-writecurrentNID Series card QOS Port6 Egress Enabled 0: NO 1: YES
1.3.6.1.4.1.4756.20.500.20.1.1650ColumnnidQOSPort6EgressRateLocalread-writecurrentNID Series card QOS Port6 Egress Rate
1.3.6.1.4.1.4756.20.500.20.1.1651ColumnnidQOSPort6EgressRateUnitLocalread-writecurrentNID Series card QOS Port6 Egress Rate Unit 0: Kbps 1: Mbps
1.3.6.1.4.1.4756.20.500.20.1.1652ColumnnidQOSPort7EgressLocalread-writecurrentNID Series card QOS Port7 Egress Enabled 0: NO 1: YES
1.3.6.1.4.1.4756.20.500.20.1.1653ColumnnidQOSPort7EgressRateLocalread-writecurrentNID Series card QOS Port7 Egress Rate
1.3.6.1.4.1.4756.20.500.20.1.1654ColumnnidQOSPort7EgressRateUnitLocalread-writecurrentNID Series card QOS Port7 Egress Rate Unit 0: Kbps 1: Mbps
1.3.6.1.4.1.4756.20.500.20.1.1655ColumnnidQOSPort8EgressLocalread-writecurrentNID Series card QOS Port8 Egress Enabled 0: NO 1: YES
1.3.6.1.4.1.4756.20.500.20.1.1656ColumnnidQOSPort8EgressRateLocalread-writecurrentNID Series card QOS Port8 Egress Rate
1.3.6.1.4.1.4756.20.500.20.1.1657ColumnnidQOSPort8EgressRateUnitLocalread-writecurrentNID Series card QOS Port8 Egress Rate Unit 0: Kbps 1: Mbps
1.3.6.1.4.1.4756.20.500.20.1.1658ColumnnidQOSUnicastLocalread-writecurrentNID Series card QOS Storm Control Configuration- Unicast 0: NO 1: YES
1.3.6.1.4.1.4756.20.500.20.1.1659ColumnnidQOSUnicastRateLocalread-writecurrentNID Series card QOS Storm Control Configuration- Unicast Rate The rate unit is packets per second (pps). 0: 1 1: 2 2: 4 3: 8 4: 16 5: 32 6: 64 7: 128 8: 256 9:…
1.3.6.1.4.1.4756.20.500.20.1.1660ColumnnidQOSMulticastLocalread-writecurrentNID Series card QOS Storm Control Configuration- Multicast 0: NO 1: YES
1.3.6.1.4.1.4756.20.500.20.1.1661ColumnnidQOSMulticastRateLocalread-writecurrentNID Series card QOS Storm Control Configuration- Multicast The rate unit is packets per second (pps). 0: 1 1: 2 2: 4 3: 8 4: 16 5: 32 6: 64 7: 128 8: 256 9: 51…
1.3.6.1.4.1.4756.20.500.20.1.1662ColumnnidQOSBroadcastLocalread-writecurrentNID Series card QOS Storm Control Configuration- Broadcast 0: NO 1: YES
1.3.6.1.4.1.4756.20.500.20.1.1663ColumnnidQOSBroadcastRateLocalread-writecurrentNID Series card QOS Storm Control Configuration- Broadcast The rate unit is packets per second (pps). 0: 1 1: 2 2: 4 3: 8 4: 16 5: 32 6: 64 7: 128 8: 256 9: 51…
1.3.6.1.4.1.4756.20.500.20.1.1664ColumnnidL2CPPort1DMAC0180C2000000Localread-writecurrentNID Series card Port 1 L2CP Mode 0180C2000000 0: Forward 1: Discard 2: Peer
1.3.6.1.4.1.4756.20.500.20.1.1665ColumnnidL2CPPort1DMAC0180C2000001Localread-writecurrentNID Series card Port 1 L2CP Mode 0180C2000001 0: Forward 1: Discard 2: Peer
1.3.6.1.4.1.4756.20.500.20.1.1666ColumnnidL2CPPort1DMAC0180C2000002Localread-writecurrentNID Series card Port 1 L2CP Mode 0180C2000002 0: Forward 1: Discard 2: Peer
1.3.6.1.4.1.4756.20.500.20.1.1667ColumnnidL2CPPort1DMAC0180C2000003Localread-writecurrentNID Series card Port 1 L2CP Mode 0180C2000003 0: Forward 1: Discard 2: Peer
1.3.6.1.4.1.4756.20.500.20.1.1668ColumnnidL2CPPort1DMAC0180C2000004Localread-writecurrentNID Series card Port 1 L2CP Mode 0180C2000004 0: Forward 1: Discard 2: Peer
1.3.6.1.4.1.4756.20.500.20.1.1669ColumnnidL2CPPort1DMAC0180C2000005Localread-writecurrentNID Series card Port 1 L2CP Mode 0180C2000005 0: Forward 1: Discard 2: Peer
1.3.6.1.4.1.4756.20.500.20.1.1670ColumnnidL2CPPort1DMAC0180C2000006Localread-writecurrentNID Series card Port 1 L2CP Mode 0180C2000006 0: Forward 1: Discard 2: Peer
1.3.6.1.4.1.4756.20.500.20.1.1671ColumnnidL2CPPort1DMAC0180C2000007Localread-writecurrentNID Series card Port 1 L2CP Mode 0180C2000007 0: Forward 1: Discard 2: Peer
1.3.6.1.4.1.4756.20.500.20.1.1672ColumnnidL2CPPort1DMAC0180C2000008Localread-writecurrentNID Series card Port 1 L2CP Mode 0180C2000008 0: Forward 1: Discard 2: Peer
1.3.6.1.4.1.4756.20.500.20.1.1673ColumnnidL2CPPort1DMAC0180C2000009Localread-writecurrentNID Series card Port 1 L2CP Mode 0180C2000009 0: Forward 1: Discard 2: Peer
1.3.6.1.4.1.4756.20.500.20.1.1674ColumnnidL2CPPort1DMAC0180C200000ALocalread-writecurrentNID Series card Port 1 L2CP Mode 0180C200000A 0: Forward 1: Discard 2: Peer
1.3.6.1.4.1.4756.20.500.20.1.1675ColumnnidL2CPPort1DMAC0180C200000BLocalread-writecurrentNID Series card Port 1 L2CP Mode 0180C200000B 0: Forward 1: Discard 2: Peer
1.3.6.1.4.1.4756.20.500.20.1.1676ColumnnidL2CPPort1DMAC0180C200000CLocalread-writecurrentNID Series card Port 1 L2CP Mode 0180C200000C 0: Forward 1: Discard 2: Peer
1.3.6.1.4.1.4756.20.500.20.1.1677ColumnnidL2CPPort1DMAC0180C200000DLocalread-writecurrentNID Series card Port 1 L2CP Mode 0180C200000D 0: Forward 1: Discard 2: Peer
1.3.6.1.4.1.4756.20.500.20.1.1678ColumnnidL2CPPort1DMAC0180C200000ELocalread-writecurrentNID Series card Port 1 L2CP Mode 0180C200000E 0: Forward 1: Discard 2: Peer
1.3.6.1.4.1.4756.20.500.20.1.1679ColumnnidL2CPPort1DMAC0180C200000FLocalread-writecurrentNID Series card Port 1 L2CP Mode 0180C200000F 0: Forward 1: Discard 2: Peer
1.3.6.1.4.1.4756.20.500.20.1.1680ColumnnidL2CPPort1DMAC0180C2000010Localread-writecurrentNID Series card Port 1 L2CP Mode 0180C2000010 0: Forward 1: Discard 2: Peer
1.3.6.1.4.1.4756.20.500.20.1.1681ColumnnidL2CPPort1DMAC0180C2000020Localread-writecurrentNID Series card Port 1 L2CP Mode 0180C2000020 0: Forward 1: Discard 2: Peer
1.3.6.1.4.1.4756.20.500.20.1.1682ColumnnidL2CPPort1DMAC0180C2000021Localread-writecurrentNID Series card Port 1 L2CP Mode 0180C2000021 0: Forward 1: Discard 2: Peer
1.3.6.1.4.1.4756.20.500.20.1.1683ColumnnidL2CPPort1DMAC0180C2000022Localread-writecurrentNID Series card Port 1 L2CP Mode 0180C2000022 0: Forward 1: Discard 2: Peer
1.3.6.1.4.1.4756.20.500.20.1.1684ColumnnidL2CPPort1DMAC0180C2000023Localread-writecurrentNID Series card Port 1 L2CP Mode 0180C2000023 0: Forward 1: Discard 2: Peer
1.3.6.1.4.1.4756.20.500.20.1.1685ColumnnidL2CPPort1DMAC0180C2000024Localread-writecurrentNID Series card Port 1 L2CP Mode 0180C2000024 0: Forward 1: Discard 2: Peer
1.3.6.1.4.1.4756.20.500.20.1.1686ColumnnidL2CPPort1DMAC0180C2000025Localread-writecurrentNID Series card Port 1 L2CP Mode 0180C2000025 0: Forward 1: Discard 2: Peer
1.3.6.1.4.1.4756.20.500.20.1.1687ColumnnidL2CPPort1DMAC0180C2000026Localread-writecurrentNID Series card Port 1 L2CP Mode 0180C2000026 0: Forward 1: Discard 2: Peer
1.3.6.1.4.1.4756.20.500.20.1.1688ColumnnidL2CPPort1DMAC0180C2000027Localread-writecurrentNID Series card Port 1 L2CP Mode 0180C2000027 0: Forward 1: Discard 2: Peer
1.3.6.1.4.1.4756.20.500.20.1.1689ColumnnidL2CPPort1DMAC0180C2000028Localread-writecurrentNID Series card Port 1 L2CP Mode 0180C2000028 0: Forward 1: Discard 2: Peer
1.3.6.1.4.1.4756.20.500.20.1.1690ColumnnidL2CPPort1DMAC0180C2000029Localread-writecurrentNID Series card Port 1 L2CP Mode 0180C2000029 0: Forward 1: Discard 2: Peer
1.3.6.1.4.1.4756.20.500.20.1.1691ColumnnidL2CPPort1DMAC0180C200002ALocalread-writecurrentNID Series card Port 1 L2CP Mode 0180C200002A 0: Forward 1: Discard 2: Peer
1.3.6.1.4.1.4756.20.500.20.1.1692ColumnnidL2CPPort1DMAC0180C200002BLocalread-writecurrentNID Series card Port 1 L2CP Mode 0180C200002B 0: Forward 1: Discard 2: Peer
1.3.6.1.4.1.4756.20.500.20.1.1693ColumnnidL2CPPort1DMAC0180C200002CLocalread-writecurrentNID Series card Port 1 L2CP Mode 0180C200002C 0: Forward 1: Discard 2: Peer
1.3.6.1.4.1.4756.20.500.20.1.1694ColumnnidL2CPPort1DMAC0180C200002DLocalread-writecurrentNID Series card Port 1 L2CP Mode 0180C200002D 0: Forward 1: Discard 2: Peer
1.3.6.1.4.1.4756.20.500.20.1.1695ColumnnidL2CPPort1DMAC0180C200002ELocalread-writecurrentNID Series card Port 1 L2CP Mode 0180C200002E 0: Forward 1: Discard 2: Peer
1.3.6.1.4.1.4756.20.500.20.1.1696ColumnnidL2CPPort1DMAC0180C200002FLocalread-writecurrentNID Series card Port 1 L2CP Mode 0180C200002F 0: Forward 1: Discard 1: Peer
1.3.6.1.4.1.4756.20.500.20.1.1697ColumnnidL2CPPort2DMAC0180C2000000Localread-writecurrentNID Series card Port 2 L2CP Mode 0180C2000000 0: Forward 1: Discard 2: Peer
1.3.6.1.4.1.4756.20.500.20.1.1698ColumnnidL2CPPort2DMAC0180C2000001Localread-writecurrentNID Series card Port 2 L2CP Mode 0180C2000001 0: Forward 1: Discard 2: Peer
1.3.6.1.4.1.4756.20.500.20.1.1699ColumnnidL2CPPort2DMAC0180C2000002Localread-writecurrentNID Series card Port 2 L2CP Mode 0180C2000002 0: Forward 1: Discard 2: Peer
1.3.6.1.4.1.4756.20.500.20.1.1700ColumnnidL2CPPort2DMAC0180C2000003Localread-writecurrentNID Series card Port 2 L2CP Mode 0180C2000003 0: Forward 1: Discard 2: Peer
1.3.6.1.4.1.4756.20.500.20.1.1701ColumnnidL2CPPort2DMAC0180C2000004Localread-writecurrentNID Series card Port 2 L2CP Mode 0180C2000004 0: Forward 1: Discard 2: Peer
1.3.6.1.4.1.4756.20.500.20.1.1702ColumnnidL2CPPort2DMAC0180C2000005Localread-writecurrentNID Series card Port 2 L2CP Mode 0180C2000005 0: Forward 1: Discard 2: Peer
1.3.6.1.4.1.4756.20.500.20.1.1703ColumnnidL2CPPort2DMAC0180C2000006Localread-writecurrentNID Series card Port 2 L2CP Mode 0180C2000006 0: Forward 1: Discard 2: Peer
1.3.6.1.4.1.4756.20.500.20.1.1704ColumnnidL2CPPort2DMAC0180C2000007Localread-writecurrentNID Series card Port 2 L2CP Mode 0180C2000007 0: Forward 1: Discard 2: Peer
1.3.6.1.4.1.4756.20.500.20.1.1705ColumnnidL2CPPort2DMAC0180C2000008Localread-writecurrentNID Series card Port 2 L2CP Mode 0180C2000008 0: Forward 1: Discard 2: Peer
1.3.6.1.4.1.4756.20.500.20.1.1706ColumnnidL2CPPort2DMAC0180C2000009Localread-writecurrentNID Series card Port 2 L2CP Mode 0180C2000009 0: Forward 1: Discard 2: Peer
1.3.6.1.4.1.4756.20.500.20.1.1707ColumnnidL2CPPort2DMAC0180C200000ALocalread-writecurrentNID Series card Port 2 L2CP Mode 0180C200000A 0: Forward 1: Discard 2: Peer
1.3.6.1.4.1.4756.20.500.20.1.1708ColumnnidL2CPPort2DMAC0180C200000BLocalread-writecurrentNID Series card Port 2 L2CP Mode 0180C200000B 0: Forward 1: Discard 2: Peer
1.3.6.1.4.1.4756.20.500.20.1.1709ColumnnidL2CPPort2DMAC0180C200000CLocalread-writecurrentNID Series card Port 2 L2CP Mode 0180C200000C 0: Forward 1: Discard 2: Peer
1.3.6.1.4.1.4756.20.500.20.1.1710ColumnnidL2CPPort2DMAC0180C200000DLocalread-writecurrentNID Series card Port 2 L2CP Mode 0180C200000D 0: Forward 1: Discard 2: Peer
1.3.6.1.4.1.4756.20.500.20.1.1711ColumnnidL2CPPort2DMAC0180C200000ELocalread-writecurrentNID Series card Port 2 L2CP Mode 0180C200000E 0: Forward 1: Discard 2: Peer
1.3.6.1.4.1.4756.20.500.20.1.1712ColumnnidL2CPPort2DMAC0180C200000FLocalread-writecurrentNID Series card Port 2 L2CP Mode 0180C200000F 0: Forward 1: Discard 2: Peer
1.3.6.1.4.1.4756.20.500.20.1.1713ColumnnidL2CPPort2DMAC0180C2000010Localread-writecurrentNID Series card Port 2 L2CP Mode 0180C2000010 0: Forward 1: Discard 2: Peer
1.3.6.1.4.1.4756.20.500.20.1.1714ColumnnidL2CPPort2DMAC0180C2000020Localread-writecurrentNID Series card Port 2 L2CP Mode 0180C2000020 0: Forward 1: Discard 2: Peer
1.3.6.1.4.1.4756.20.500.20.1.1715ColumnnidL2CPPort2DMAC0180C2000021Localread-writecurrentNID Series card Port 2 L2CP Mode 0180C2000021 0: Forward 1: Discard 2: Peer
1.3.6.1.4.1.4756.20.500.20.1.1716ColumnnidL2CPPort2DMAC0180C2000022Localread-writecurrentNID Series card Port 2 L2CP Mode 0180C2000022 0: Forward 1: Discard 2: Peer
1.3.6.1.4.1.4756.20.500.20.1.1717ColumnnidL2CPPort2DMAC0180C2000023Localread-writecurrentNID Series card Port 2 L2CP Mode 0180C2000023 0: Forward 1: Discard 2: Peer
1.3.6.1.4.1.4756.20.500.20.1.1718ColumnnidL2CPPort2DMAC0180C2000024Localread-writecurrentNID Series card Port 2 L2CP Mode 0180C2000024 0: Forward 1: Discard 2: Peer
1.3.6.1.4.1.4756.20.500.20.1.1719ColumnnidL2CPPort2DMAC0180C2000025Localread-writecurrentNID Series card Port 2 L2CP Mode 0180C2000025 0: Forward 1: Discard 2: Peer
1.3.6.1.4.1.4756.20.500.20.1.1720ColumnnidL2CPPort2DMAC0180C2000026Localread-writecurrentNID Series card Port 2 L2CP Mode 0180C2000026 0: Forward 1: Discard 2: Peer
1.3.6.1.4.1.4756.20.500.20.1.1721ColumnnidL2CPPort2DMAC0180C2000027Localread-writecurrentNID Series card Port 2 L2CP Mode 0180C2000027 0: Forward 1: Discard 2: Peer
1.3.6.1.4.1.4756.20.500.20.1.1722ColumnnidL2CPPort2DMAC0180C2000028Localread-writecurrentNID Series card Port 2 L2CP Mode 0180C2000028 0: Forward 1: Discard 2: Peer
1.3.6.1.4.1.4756.20.500.20.1.1723ColumnnidL2CPPort2DMAC0180C2000029Localread-writecurrentNID Series card Port 2 L2CP Mode 0180C2000029 0: Forward 1: Discard 2: Peer
1.3.6.1.4.1.4756.20.500.20.1.1724ColumnnidL2CPPort2DMAC0180C200002ALocalread-writecurrentNID Series card Port 2 L2CP Mode 0180C200002A 0: Forward 1: Discard 2: Peer
1.3.6.1.4.1.4756.20.500.20.1.1725ColumnnidL2CPPort2DMAC0180C200002BLocalread-writecurrentNID Series card Port 2 L2CP Mode 0180C200002B 0: Forward 1: Discard 2: Peer
1.3.6.1.4.1.4756.20.500.20.1.1726ColumnnidL2CPPort2DMAC0180C200002CLocalread-writecurrentNID Series card Port 2 L2CP Mode 0180C200002C 0: Forward 1: Discard 2: Peer
1.3.6.1.4.1.4756.20.500.20.1.1727ColumnnidL2CPPort2DMAC0180C200002DLocalread-writecurrentNID Series card Port 2 L2CP Mode 0180C200002D 0: Forward 1: Discard 2: Peer
1.3.6.1.4.1.4756.20.500.20.1.1728ColumnnidL2CPPort2DMAC0180C200002ELocalread-writecurrentNID Series card Port 2 L2CP Mode 0180C200002E 0: Forward 1: Discard 2: Peer
1.3.6.1.4.1.4756.20.500.20.1.1729ColumnnidL2CPPort2DMAC0180C200002FLocalread-writecurrentNID Series card Port 2 L2CP Mode 0180C200002F 0: Forward 1: Discard 1: Peer
1.3.6.1.4.1.4756.20.500.20.1.1730ColumnnidL2CPPort3DMAC0180C2000000Localread-writecurrentNID Series card Port 3 L2CP Mode 0180C2000000 0: Forward 1: Discard 2: Peer
1.3.6.1.4.1.4756.20.500.20.1.1731ColumnnidL2CPPort3DMAC0180C2000001Localread-writecurrentNID Series card Port 3 L2CP Mode 0180C2000001 0: Forward 1: Discard 2: Peer
1.3.6.1.4.1.4756.20.500.20.1.1732ColumnnidL2CPPort3DMAC0180C2000002Localread-writecurrentNID Series card Port 3 L2CP Mode 0180C2000002 0: Forward 1: Discard 2: Peer
1.3.6.1.4.1.4756.20.500.20.1.1733ColumnnidL2CPPort3DMAC0180C2000003Localread-writecurrentNID Series card Port 3 L2CP Mode 0180C2000003 0: Forward 1: Discard 2: Peer
1.3.6.1.4.1.4756.20.500.20.1.1734ColumnnidL2CPPort3DMAC0180C2000004Localread-writecurrentNID Series card Port 3 L2CP Mode 0180C2000004 0: Forward 1: Discard 2: Peer
1.3.6.1.4.1.4756.20.500.20.1.1735ColumnnidL2CPPort3DMAC0180C2000005Localread-writecurrentNID Series card Port 3 L2CP Mode 0180C2000005 0: Forward 1: Discard 2: Peer
1.3.6.1.4.1.4756.20.500.20.1.1736ColumnnidL2CPPort3DMAC0180C2000006Localread-writecurrentNID Series card Port 3 L2CP Mode 0180C2000006 0: Forward 1: Discard 2: Peer
1.3.6.1.4.1.4756.20.500.20.1.1737ColumnnidL2CPPort3DMAC0180C2000007Localread-writecurrentNID Series card Port 3 L2CP Mode 0180C2000007 0: Forward 1: Discard 2: Peer
1.3.6.1.4.1.4756.20.500.20.1.1738ColumnnidL2CPPort3DMAC0180C2000008Localread-writecurrentNID Series card Port 3 L2CP Mode 0180C2000008 0: Forward 1: Discard 2: Peer
1.3.6.1.4.1.4756.20.500.20.1.1739ColumnnidL2CPPort3DMAC0180C2000009Localread-writecurrentNID Series card Port 3 L2CP Mode 0180C2000009 0: Forward 1: Discard 2: Peer
1.3.6.1.4.1.4756.20.500.20.1.1740ColumnnidL2CPPort3DMAC0180C200000ALocalread-writecurrentNID Series card Port 3 L2CP Mode 0180C200000A 0: Forward 1: Discard 2: Peer
1.3.6.1.4.1.4756.20.500.20.1.1741ColumnnidL2CPPort3DMAC0180C200000BLocalread-writecurrentNID Series card Port 3 L2CP Mode 0180C200000B 0: Forward 1: Discard 2: Peer
1.3.6.1.4.1.4756.20.500.20.1.1742ColumnnidL2CPPort3DMAC0180C200000CLocalread-writecurrentNID Series card Port 3 L2CP Mode 0180C200000C 0: Forward 1: Discard 2: Peer
1.3.6.1.4.1.4756.20.500.20.1.1743ColumnnidL2CPPort3DMAC0180C200000DLocalread-writecurrentNID Series card Port 3 L2CP Mode 0180C200000D 0: Forward 1: Discard 2: Peer
1.3.6.1.4.1.4756.20.500.20.1.1744ColumnnidL2CPPort3DMAC0180C200000ELocalread-writecurrentNID Series card Port 3 L2CP Mode 0180C200000E 0: Forward 1: Discard 2: Peer
1.3.6.1.4.1.4756.20.500.20.1.1745ColumnnidL2CPPort3DMAC0180C200000FLocalread-writecurrentNID Series card Port 3 L2CP Mode 0180C200000F 0: Forward 1: Discard 2: Peer
1.3.6.1.4.1.4756.20.500.20.1.1746ColumnnidL2CPPort3DMAC0180C2000010Localread-writecurrentNID Series card Port 3 L2CP Mode 0180C2000010 0: Forward 1: Discard 2: Peer
1.3.6.1.4.1.4756.20.500.20.1.1747ColumnnidL2CPPort3DMAC0180C2000020Localread-writecurrentNID Series card Port 3 L2CP Mode 0180C2000020 0: Forward 1: Discard 2: Peer
1.3.6.1.4.1.4756.20.500.20.1.1748ColumnnidL2CPPort3DMAC0180C2000021Localread-writecurrentNID Series card Port 3 L2CP Mode 0180C2000021 0: Forward 1: Discard 2: Peer
1.3.6.1.4.1.4756.20.500.20.1.1749ColumnnidL2CPPort3DMAC0180C2000022Localread-writecurrentNID Series card Port 3 L2CP Mode 0180C2000022 0: Forward 1: Discard 2: Peer
1.3.6.1.4.1.4756.20.500.20.1.1750ColumnnidL2CPPort3DMAC0180C2000023Localread-writecurrentNID Series card Port 3 L2CP Mode 0180C2000023 0: Forward 1: Discard 2: Peer
1.3.6.1.4.1.4756.20.500.20.1.1751ColumnnidL2CPPort3DMAC0180C2000024Localread-writecurrentNID Series card Port 3 L2CP Mode 0180C2000024 0: Forward 1: Discard 2: Peer
1.3.6.1.4.1.4756.20.500.20.1.1752ColumnnidL2CPPort3DMAC0180C2000025Localread-writecurrentNID Series card Port 3 L2CP Mode 0180C2000025 0: Forward 1: Discard 2: Peer
1.3.6.1.4.1.4756.20.500.20.1.1753ColumnnidL2CPPort3DMAC0180C2000026Localread-writecurrentNID Series card Port 3 L2CP Mode 0180C2000026 0: Forward 1: Discard 2: Peer
1.3.6.1.4.1.4756.20.500.20.1.1754ColumnnidL2CPPort3DMAC0180C2000027Localread-writecurrentNID Series card Port 3 L2CP Mode 0180C2000027 0: Forward 1: Discard 2: Peer
1.3.6.1.4.1.4756.20.500.20.1.1755ColumnnidL2CPPort3DMAC0180C2000028Localread-writecurrentNID Series card Port 3 L2CP Mode 0180C2000028 0: Forward 1: Discard 2: Peer
1.3.6.1.4.1.4756.20.500.20.1.1756ColumnnidL2CPPort3DMAC0180C2000029Localread-writecurrentNID Series card Port 3 L2CP Mode 0180C2000029 0: Forward 1: Discard 2: Peer
1.3.6.1.4.1.4756.20.500.20.1.1757ColumnnidL2CPPort3DMAC0180C200002ALocalread-writecurrentNID Series card Port 3 L2CP Mode 0180C200002A 0: Forward 1: Discard 2: Peer
1.3.6.1.4.1.4756.20.500.20.1.1758ColumnnidL2CPPort3DMAC0180C200002BLocalread-writecurrentNID Series card Port 3 L2CP Mode 0180C200002B 0: Forward 1: Discard 2: Peer
1.3.6.1.4.1.4756.20.500.20.1.1759ColumnnidL2CPPort3DMAC0180C200002CLocalread-writecurrentNID Series card Port 3 L2CP Mode 0180C200002C 0: Forward 1: Discard 2: Peer
1.3.6.1.4.1.4756.20.500.20.1.1760ColumnnidL2CPPort3DMAC0180C200002DLocalread-writecurrentNID Series card Port 3 L2CP Mode 0180C200002D 0: Forward 1: Discard 2: Peer
1.3.6.1.4.1.4756.20.500.20.1.1761ColumnnidL2CPPort3DMAC0180C200002ELocalread-writecurrentNID Series card Port 3 L2CP Mode 0180C200002E 0: Forward 1: Discard 2: Peer
1.3.6.1.4.1.4756.20.500.20.1.1762ColumnnidL2CPPort3DMAC0180C200002FLocalread-writecurrentNID Series card Port 3 L2CP Mode 0180C200002F 0: Forward 1: Discard 1: Peer
1.3.6.1.4.1.4756.20.500.20.1.1763ColumnnidL2CPPort4DMAC0180C2000000Localread-writecurrentNID Series card Port 4 L2CP Mode 0180C2000000 0: Forward 1: Discard 2: Peer
1.3.6.1.4.1.4756.20.500.20.1.1764ColumnnidL2CPPort4DMAC0180C2000001Localread-writecurrentNID Series card Port 4 L2CP Mode 0180C2000001 0: Forward 1: Discard 2: Peer
1.3.6.1.4.1.4756.20.500.20.1.1765ColumnnidL2CPPort4DMAC0180C2000002Localread-writecurrentNID Series card Port 4 L2CP Mode 0180C2000002 0: Forward 1: Discard 2: Peer
1.3.6.1.4.1.4756.20.500.20.1.1766ColumnnidL2CPPort4DMAC0180C2000003Localread-writecurrentNID Series card Port 4 L2CP Mode 0180C2000003 0: Forward 1: Discard 2: Peer
1.3.6.1.4.1.4756.20.500.20.1.1767ColumnnidL2CPPort4DMAC0180C2000004Localread-writecurrentNID Series card Port 4 L2CP Mode 0180C2000004 0: Forward 1: Discard 2: Peer
1.3.6.1.4.1.4756.20.500.20.1.1768ColumnnidL2CPPort4DMAC0180C2000005Localread-writecurrentNID Series card Port 4 L2CP Mode 0180C2000005 0: Forward 1: Discard 2: Peer
1.3.6.1.4.1.4756.20.500.20.1.1769ColumnnidL2CPPort4DMAC0180C2000006Localread-writecurrentNID Series card Port 4 L2CP Mode 0180C2000006 0: Forward 1: Discard 2: Peer
1.3.6.1.4.1.4756.20.500.20.1.1770ColumnnidL2CPPort4DMAC0180C2000007Localread-writecurrentNID Series card Port 4 L2CP Mode 0180C2000007 0: Forward 1: Discard 2: Peer
1.3.6.1.4.1.4756.20.500.20.1.1771ColumnnidL2CPPort4DMAC0180C2000008Localread-writecurrentNID Series card Port 4 L2CP Mode 0180C2000008 0: Forward 1: Discard 2: Peer
1.3.6.1.4.1.4756.20.500.20.1.1772ColumnnidL2CPPort4DMAC0180C2000009Localread-writecurrentNID Series card Port 4 L2CP Mode 0180C2000009 0: Forward 1: Discard 2: Peer
1.3.6.1.4.1.4756.20.500.20.1.1773ColumnnidL2CPPort4DMAC0180C200000ALocalread-writecurrentNID Series card Port 4 L2CP Mode 0180C200000A 0: Forward 1: Discard 2: Peer
1.3.6.1.4.1.4756.20.500.20.1.1774ColumnnidL2CPPort4DMAC0180C200000BLocalread-writecurrentNID Series card Port 4 L2CP Mode 0180C200000B 0: Forward 1: Discard 2: Peer
1.3.6.1.4.1.4756.20.500.20.1.1775ColumnnidL2CPPort4DMAC0180C200000CLocalread-writecurrentNID Series card Port 4 L2CP Mode 0180C200000C 0: Forward 1: Discard 2: Peer
1.3.6.1.4.1.4756.20.500.20.1.1776ColumnnidL2CPPort4DMAC0180C200000DLocalread-writecurrentNID Series card Port 4 L2CP Mode 0180C200000D 0: Forward 1: Discard 2: Peer
1.3.6.1.4.1.4756.20.500.20.1.1777ColumnnidL2CPPort4DMAC0180C200000ELocalread-writecurrentNID Series card Port 4 L2CP Mode 0180C200000E 0: Forward 1: Discard 2: Peer
1.3.6.1.4.1.4756.20.500.20.1.1778ColumnnidL2CPPort4DMAC0180C200000FLocalread-writecurrentNID Series card Port 4 L2CP Mode 0180C200000F 0: Forward 1: Discard 2: Peer
1.3.6.1.4.1.4756.20.500.20.1.1779ColumnnidL2CPPort4DMAC0180C2000010Localread-writecurrentNID Series card Port 4 L2CP Mode 0180C2000010 0: Forward 1: Discard 2: Peer
1.3.6.1.4.1.4756.20.500.20.1.1780ColumnnidL2CPPort4DMAC0180C2000020Localread-writecurrentNID Series card Port 4 L2CP Mode 0180C2000020 0: Forward 1: Discard 2: Peer
1.3.6.1.4.1.4756.20.500.20.1.1781ColumnnidL2CPPort4DMAC0180C2000021Localread-writecurrentNID Series card Port 4 L2CP Mode 0180C2000021 0: Forward 1: Discard 2: Peer
1.3.6.1.4.1.4756.20.500.20.1.1782ColumnnidL2CPPort4DMAC0180C2000022Localread-writecurrentNID Series card Port 4 L2CP Mode 0180C2000022 0: Forward 1: Discard 2: Peer
1.3.6.1.4.1.4756.20.500.20.1.1783ColumnnidL2CPPort4DMAC0180C2000023Localread-writecurrentNID Series card Port 4 L2CP Mode 0180C2000023 0: Forward 1: Discard 2: Peer
1.3.6.1.4.1.4756.20.500.20.1.1784ColumnnidL2CPPort4DMAC0180C2000024Localread-writecurrentNID Series card Port 4 L2CP Mode 0180C2000024 0: Forward 1: Discard 2: Peer
1.3.6.1.4.1.4756.20.500.20.1.1785ColumnnidL2CPPort4DMAC0180C2000025Localread-writecurrentNID Series card Port 4 L2CP Mode 0180C2000025 0: Forward 1: Discard 2: Peer
1.3.6.1.4.1.4756.20.500.20.1.1786ColumnnidL2CPPort4DMAC0180C2000026Localread-writecurrentNID Series card Port 4 L2CP Mode 0180C2000026 0: Forward 1: Discard 2: Peer
1.3.6.1.4.1.4756.20.500.20.1.1787ColumnnidL2CPPort4DMAC0180C2000027Localread-writecurrentNID Series card Port 4 L2CP Mode 0180C2000027 0: Forward 1: Discard 2: Peer
1.3.6.1.4.1.4756.20.500.20.1.1788ColumnnidL2CPPort4DMAC0180C2000028Localread-writecurrentNID Series card Port 4 L2CP Mode 0180C2000028 0: Forward 1: Discard 2: Peer
1.3.6.1.4.1.4756.20.500.20.1.1789ColumnnidL2CPPort4DMAC0180C2000029Localread-writecurrentNID Series card Port 4 L2CP Mode 0180C2000029 0: Forward 1: Discard 2: Peer
1.3.6.1.4.1.4756.20.500.20.1.1790ColumnnidL2CPPort4DMAC0180C200002ALocalread-writecurrentNID Series card Port 4 L2CP Mode 0180C200002A 0: Forward 1: Discard 2: Peer
1.3.6.1.4.1.4756.20.500.20.1.1791ColumnnidL2CPPort4DMAC0180C200002BLocalread-writecurrentNID Series card Port 4 L2CP Mode 0180C200002B 0: Forward 1: Discard 2: Peer
1.3.6.1.4.1.4756.20.500.20.1.1792ColumnnidL2CPPort4DMAC0180C200002CLocalread-writecurrentNID Series card Port 4 L2CP Mode 0180C200002C 0: Forward 1: Discard 2: Peer
1.3.6.1.4.1.4756.20.500.20.1.1793ColumnnidL2CPPort4DMAC0180C200002DLocalread-writecurrentNID Series card Port 4 L2CP Mode 0180C200002D 0: Forward 1: Discard 2: Peer
1.3.6.1.4.1.4756.20.500.20.1.1794ColumnnidL2CPPort4DMAC0180C200002ELocalread-writecurrentNID Series card Port 4 L2CP Mode 0180C200002E 0: Forward 1: Discard 2: Peer
1.3.6.1.4.1.4756.20.500.20.1.1795ColumnnidL2CPPort4DMAC0180C200002FLocalread-writecurrentNID Series card Port 4 L2CP Mode 0180C200002F 0: Forward 1: Discard 1: Peer
1.3.6.1.4.1.4756.20.500.20.1.1796ColumnnidL2CPPort5DMAC0180C2000000Localread-writecurrentNID Series card Port 5 L2CP Mode 0180C2000000 0: Forward 1: Discard 2: Peer
1.3.6.1.4.1.4756.20.500.20.1.1797ColumnnidL2CPPort5DMAC0180C2000001Localread-writecurrentNID Series card Port 5 L2CP Mode 0180C2000001 0: Forward 1: Discard 2: Peer
1.3.6.1.4.1.4756.20.500.20.1.1798ColumnnidL2CPPort5DMAC0180C2000002Localread-writecurrentNID Series card Port 5 L2CP Mode 0180C2000002 0: Forward 1: Discard 2: Peer
1.3.6.1.4.1.4756.20.500.20.1.1799ColumnnidL2CPPort5DMAC0180C2000003Localread-writecurrentNID Series card Port 5 L2CP Mode 0180C2000003 0: Forward 1: Discard 2: Peer
1.3.6.1.4.1.4756.20.500.20.1.1800ColumnnidL2CPPort5DMAC0180C2000004Localread-writecurrentNID Series card Port 5 L2CP Mode 0180C2000004 0: Forward 1: Discard 2: Peer
1.3.6.1.4.1.4756.20.500.20.1.1801ColumnnidL2CPPort5DMAC0180C2000005Localread-writecurrentNID Series card Port 5 L2CP Mode 0180C2000005 0: Forward 1: Discard 2: Peer
1.3.6.1.4.1.4756.20.500.20.1.1802ColumnnidL2CPPort5DMAC0180C2000006Localread-writecurrentNID Series card Port 5 L2CP Mode 0180C2000006 0: Forward 1: Discard 2: Peer
1.3.6.1.4.1.4756.20.500.20.1.1803ColumnnidL2CPPort5DMAC0180C2000007Localread-writecurrentNID Series card Port 5 L2CP Mode 0180C2000007 0: Forward 1: Discard 2: Peer
1.3.6.1.4.1.4756.20.500.20.1.1804ColumnnidL2CPPort5DMAC0180C2000008Localread-writecurrentNID Series card Port 5 L2CP Mode 0180C2000008 0: Forward 1: Discard 2: Peer
1.3.6.1.4.1.4756.20.500.20.1.1805ColumnnidL2CPPort5DMAC0180C2000009Localread-writecurrentNID Series card Port 5 L2CP Mode 0180C2000009 0: Forward 1: Discard 2: Peer
1.3.6.1.4.1.4756.20.500.20.1.1806ColumnnidL2CPPort5DMAC0180C200000ALocalread-writecurrentNID Series card Port 5 L2CP Mode 0180C200000A 0: Forward 1: Discard 2: Peer
1.3.6.1.4.1.4756.20.500.20.1.1807ColumnnidL2CPPort5DMAC0180C200000BLocalread-writecurrentNID Series card Port 5 L2CP Mode 0180C200000B 0: Forward 1: Discard 2: Peer
1.3.6.1.4.1.4756.20.500.20.1.1808ColumnnidL2CPPort5DMAC0180C200000CLocalread-writecurrentNID Series card Port 5 L2CP Mode 0180C200000C 0: Forward 1: Discard 2: Peer
1.3.6.1.4.1.4756.20.500.20.1.1809ColumnnidL2CPPort5DMAC0180C200000DLocalread-writecurrentNID Series card Port 5 L2CP Mode 0180C200000D 0: Forward 1: Discard 2: Peer
1.3.6.1.4.1.4756.20.500.20.1.1810ColumnnidL2CPPort5DMAC0180C200000ELocalread-writecurrentNID Series card Port 5 L2CP Mode 0180C200000E 0: Forward 1: Discard 2: Peer
1.3.6.1.4.1.4756.20.500.20.1.1811ColumnnidL2CPPort5DMAC0180C200000FLocalread-writecurrentNID Series card Port 5 L2CP Mode 0180C200000F 0: Forward 1: Discard 2: Peer
1.3.6.1.4.1.4756.20.500.20.1.1812ColumnnidL2CPPort5DMAC0180C2000010Localread-writecurrentNID Series card Port 5 L2CP Mode 0180C2000010 0: Forward 1: Discard 2: Peer
1.3.6.1.4.1.4756.20.500.20.1.1813ColumnnidL2CPPort5DMAC0180C2000020Localread-writecurrentNID Series card Port 5 L2CP Mode 0180C2000020 0: Forward 1: Discard 2: Peer
1.3.6.1.4.1.4756.20.500.20.1.1814ColumnnidL2CPPort5DMAC0180C2000021Localread-writecurrentNID Series card Port 5 L2CP Mode 0180C2000021 0: Forward 1: Discard 2: Peer
1.3.6.1.4.1.4756.20.500.20.1.1815ColumnnidL2CPPort5DMAC0180C2000022Localread-writecurrentNID Series card Port 5 L2CP Mode 0180C2000022 0: Forward 1: Discard 2: Peer
1.3.6.1.4.1.4756.20.500.20.1.1816ColumnnidL2CPPort5DMAC0180C2000023Localread-writecurrentNID Series card Port 5 L2CP Mode 0180C2000023 0: Forward 1: Discard 2: Peer
1.3.6.1.4.1.4756.20.500.20.1.1817ColumnnidL2CPPort5DMAC0180C2000024Localread-writecurrentNID Series card Port 5 L2CP Mode 0180C2000024 0: Forward 1: Discard 2: Peer
1.3.6.1.4.1.4756.20.500.20.1.1818ColumnnidL2CPPort5DMAC0180C2000025Localread-writecurrentNID Series card Port 5 L2CP Mode 0180C2000025 0: Forward 1: Discard 2: Peer
1.3.6.1.4.1.4756.20.500.20.1.1819ColumnnidL2CPPort5DMAC0180C2000026Localread-writecurrentNID Series card Port 5 L2CP Mode 0180C2000026 0: Forward 1: Discard 2: Peer
1.3.6.1.4.1.4756.20.500.20.1.1820ColumnnidL2CPPort5DMAC0180C2000027Localread-writecurrentNID Series card Port 5 L2CP Mode 0180C2000027 0: Forward 1: Discard 2: Peer
1.3.6.1.4.1.4756.20.500.20.1.1821ColumnnidL2CPPort5DMAC0180C2000028Localread-writecurrentNID Series card Port 5 L2CP Mode 0180C2000028 0: Forward 1: Discard 2: Peer
1.3.6.1.4.1.4756.20.500.20.1.1822ColumnnidL2CPPort5DMAC0180C2000029Localread-writecurrentNID Series card Port 5 L2CP Mode 0180C2000029 0: Forward 1: Discard 2: Peer
1.3.6.1.4.1.4756.20.500.20.1.1823ColumnnidL2CPPort5DMAC0180C200002ALocalread-writecurrentNID Series card Port 5 L2CP Mode 0180C200002A 0: Forward 1: Discard 2: Peer
1.3.6.1.4.1.4756.20.500.20.1.1824ColumnnidL2CPPort5DMAC0180C200002BLocalread-writecurrentNID Series card Port 5 L2CP Mode 0180C200002B 0: Forward 1: Discard 2: Peer
1.3.6.1.4.1.4756.20.500.20.1.1825ColumnnidL2CPPort5DMAC0180C200002CLocalread-writecurrentNID Series card Port 5 L2CP Mode 0180C200002C 0: Forward 1: Discard 2: Peer
1.3.6.1.4.1.4756.20.500.20.1.1826ColumnnidL2CPPort5DMAC0180C200002DLocalread-writecurrentNID Series card Port 5 L2CP Mode 0180C200002D 0: Forward 1: Discard 2: Peer
1.3.6.1.4.1.4756.20.500.20.1.1827ColumnnidL2CPPort5DMAC0180C200002ELocalread-writecurrentNID Series card Port 5 L2CP Mode 0180C200002E 0: Forward 1: Discard 2: Peer
1.3.6.1.4.1.4756.20.500.20.1.1828ColumnnidL2CPPort5DMAC0180C200002FLocalread-writecurrentNID Series card Port 5 L2CP Mode 0180C200002F 0: Forward 1: Discard 1: Peer
1.3.6.1.4.1.4756.20.500.20.1.1829ColumnnidL2CPPort6DMAC0180C2000000Localread-writecurrentNID Series card Port 6 L2CP Mode 0180C2000000 0: Forward 1: Discard 2: Peer
1.3.6.1.4.1.4756.20.500.20.1.1830ColumnnidL2CPPort6DMAC0180C2000001Localread-writecurrentNID Series card Port 6 L2CP Mode 0180C2000001 0: Forward 1: Discard 2: Peer
1.3.6.1.4.1.4756.20.500.20.1.1831ColumnnidL2CPPort6DMAC0180C2000002Localread-writecurrentNID Series card Port 6 L2CP Mode 0180C2000002 0: Forward 1: Discard 2: Peer
1.3.6.1.4.1.4756.20.500.20.1.1832ColumnnidL2CPPort6DMAC0180C2000003Localread-writecurrentNID Series card Port 6 L2CP Mode 0180C2000003 0: Forward 1: Discard 2: Peer
1.3.6.1.4.1.4756.20.500.20.1.1833ColumnnidL2CPPort6DMAC0180C2000004Localread-writecurrentNID Series card Port 6 L2CP Mode 0180C2000004 0: Forward 1: Discard 2: Peer
1.3.6.1.4.1.4756.20.500.20.1.1834ColumnnidL2CPPort6DMAC0180C2000005Localread-writecurrentNID Series card Port 6 L2CP Mode 0180C2000005 0: Forward 1: Discard 2: Peer
1.3.6.1.4.1.4756.20.500.20.1.1835ColumnnidL2CPPort6DMAC0180C2000006Localread-writecurrentNID Series card Port 6 L2CP Mode 0180C2000006 0: Forward 1: Discard 2: Peer
1.3.6.1.4.1.4756.20.500.20.1.1836ColumnnidL2CPPort6DMAC0180C2000007Localread-writecurrentNID Series card Port 6 L2CP Mode 0180C2000007 0: Forward 1: Discard 2: Peer
1.3.6.1.4.1.4756.20.500.20.1.1837ColumnnidL2CPPort6DMAC0180C2000008Localread-writecurrentNID Series card Port 6 L2CP Mode 0180C2000008 0: Forward 1: Discard 2: Peer
1.3.6.1.4.1.4756.20.500.20.1.1838ColumnnidL2CPPort6DMAC0180C2000009Localread-writecurrentNID Series card Port 6 L2CP Mode 0180C2000009 0: Forward 1: Discard 2: Peer
1.3.6.1.4.1.4756.20.500.20.1.1839ColumnnidL2CPPort6DMAC0180C200000ALocalread-writecurrentNID Series card Port 6 L2CP Mode 0180C200000A 0: Forward 1: Discard 2: Peer
1.3.6.1.4.1.4756.20.500.20.1.1840ColumnnidL2CPPort6DMAC0180C200000BLocalread-writecurrentNID Series card Port 6 L2CP Mode 0180C200000B 0: Forward 1: Discard 2: Peer
1.3.6.1.4.1.4756.20.500.20.1.1841ColumnnidL2CPPort6DMAC0180C200000CLocalread-writecurrentNID Series card Port 6 L2CP Mode 0180C200000C 0: Forward 1: Discard 2: Peer
1.3.6.1.4.1.4756.20.500.20.1.1842ColumnnidL2CPPort6DMAC0180C200000DLocalread-writecurrentNID Series card Port 6 L2CP Mode 0180C200000D 0: Forward 1: Discard 2: Peer
1.3.6.1.4.1.4756.20.500.20.1.1843ColumnnidL2CPPort6DMAC0180C200000ELocalread-writecurrentNID Series card Port 6 L2CP Mode 0180C200000E 0: Forward 1: Discard 2: Peer
1.3.6.1.4.1.4756.20.500.20.1.1844ColumnnidL2CPPort6DMAC0180C200000FLocalread-writecurrentNID Series card Port 6 L2CP Mode 0180C200000F 0: Forward 1: Discard 2: Peer
1.3.6.1.4.1.4756.20.500.20.1.1845ColumnnidL2CPPort6DMAC0180C2000010Localread-writecurrentNID Series card Port 6 L2CP Mode 0180C2000010 0: Forward 1: Discard 2: Peer
1.3.6.1.4.1.4756.20.500.20.1.1846ColumnnidL2CPPort6DMAC0180C2000020Localread-writecurrentNID Series card Port 6 L2CP Mode 0180C2000020 0: Forward 1: Discard 2: Peer
1.3.6.1.4.1.4756.20.500.20.1.1847ColumnnidL2CPPort6DMAC0180C2000021Localread-writecurrentNID Series card Port 6 L2CP Mode 0180C2000021 0: Forward 1: Discard 2: Peer
1.3.6.1.4.1.4756.20.500.20.1.1848ColumnnidL2CPPort6DMAC0180C2000022Localread-writecurrentNID Series card Port 6 L2CP Mode 0180C2000022 0: Forward 1: Discard 2: Peer
1.3.6.1.4.1.4756.20.500.20.1.1849ColumnnidL2CPPort6DMAC0180C2000023Localread-writecurrentNID Series card Port 6 L2CP Mode 0180C2000023 0: Forward 1: Discard 2: Peer
1.3.6.1.4.1.4756.20.500.20.1.1850ColumnnidL2CPPort6DMAC0180C2000024Localread-writecurrentNID Series card Port 6 L2CP Mode 0180C2000024 0: Forward 1: Discard 2: Peer
1.3.6.1.4.1.4756.20.500.20.1.1851ColumnnidL2CPPort6DMAC0180C2000025Localread-writecurrentNID Series card Port 6 L2CP Mode 0180C2000025 0: Forward 1: Discard 2: Peer
1.3.6.1.4.1.4756.20.500.20.1.1852ColumnnidL2CPPort6DMAC0180C2000026Localread-writecurrentNID Series card Port 6 L2CP Mode 0180C2000026 0: Forward 1: Discard 2: Peer
1.3.6.1.4.1.4756.20.500.20.1.1853ColumnnidL2CPPort6DMAC0180C2000027Localread-writecurrentNID Series card Port 6 L2CP Mode 0180C2000027 0: Forward 1: Discard 2: Peer
1.3.6.1.4.1.4756.20.500.20.1.1854ColumnnidL2CPPort6DMAC0180C2000028Localread-writecurrentNID Series card Port 6 L2CP Mode 0180C2000028 0: Forward 1: Discard 2: Peer
1.3.6.1.4.1.4756.20.500.20.1.1855ColumnnidL2CPPort6DMAC0180C2000029Localread-writecurrentNID Series card Port 6 L2CP Mode 0180C2000029 0: Forward 1: Discard 2: Peer
1.3.6.1.4.1.4756.20.500.20.1.1856ColumnnidL2CPPort6DMAC0180C200002ALocalread-writecurrentNID Series card Port 6 L2CP Mode 0180C200002A 0: Forward 1: Discard 2: Peer
1.3.6.1.4.1.4756.20.500.20.1.1857ColumnnidL2CPPort6DMAC0180C200002BLocalread-writecurrentNID Series card Port 6 L2CP Mode 0180C200002B 0: Forward 1: Discard 2: Peer
1.3.6.1.4.1.4756.20.500.20.1.1858ColumnnidL2CPPort6DMAC0180C200002CLocalread-writecurrentNID Series card Port 6 L2CP Mode 0180C200002C 0: Forward 1: Discard 2: Peer
1.3.6.1.4.1.4756.20.500.20.1.1859ColumnnidL2CPPort6DMAC0180C200002DLocalread-writecurrentNID Series card Port 6 L2CP Mode 0180C200002D 0: Forward 1: Discard 2: Peer
1.3.6.1.4.1.4756.20.500.20.1.1860ColumnnidL2CPPort6DMAC0180C200002ELocalread-writecurrentNID Series card Port 6 L2CP Mode 0180C200002E 0: Forward 1: Discard 2: Peer
1.3.6.1.4.1.4756.20.500.20.1.1861ColumnnidL2CPPort6DMAC0180C200002FLocalread-writecurrentNID Series card Port 6 L2CP Mode 0180C200002F 0: Forward 1: Discard 1: Peer
1.3.6.1.4.1.4756.20.500.20.1.1862ColumnnidL2CPPort7DMAC0180C2000000Localread-writecurrentNID Series card Port 7 L2CP Mode 0180C2000000 0: Forward 1: Discard 2: Peer
1.3.6.1.4.1.4756.20.500.20.1.1863ColumnnidL2CPPort7DMAC0180C2000001Localread-writecurrentNID Series card Port 7 L2CP Mode 0180C2000001 0: Forward 1: Discard 2: Peer
1.3.6.1.4.1.4756.20.500.20.1.1864ColumnnidL2CPPort7DMAC0180C2000002Localread-writecurrentNID Series card Port 7 L2CP Mode 0180C2000002 0: Forward 1: Discard 2: Peer
1.3.6.1.4.1.4756.20.500.20.1.1865ColumnnidL2CPPort7DMAC0180C2000003Localread-writecurrentNID Series card Port 7 L2CP Mode 0180C2000003 0: Forward 1: Discard 2: Peer
1.3.6.1.4.1.4756.20.500.20.1.1866ColumnnidL2CPPort7DMAC0180C2000004Localread-writecurrentNID Series card Port 7 L2CP Mode 0180C2000004 0: Forward 1: Discard 2: Peer
1.3.6.1.4.1.4756.20.500.20.1.1867ColumnnidL2CPPort7DMAC0180C2000005Localread-writecurrentNID Series card Port 7 L2CP Mode 0180C2000005 0: Forward 1: Discard 2: Peer
1.3.6.1.4.1.4756.20.500.20.1.1868ColumnnidL2CPPort7DMAC0180C2000006Localread-writecurrentNID Series card Port 7 L2CP Mode 0180C2000006 0: Forward 1: Discard 2: Peer
1.3.6.1.4.1.4756.20.500.20.1.1869ColumnnidL2CPPort7DMAC0180C2000007Localread-writecurrentNID Series card Port 7 L2CP Mode 0180C2000007 0: Forward 1: Discard 2: Peer
1.3.6.1.4.1.4756.20.500.20.1.1870ColumnnidL2CPPort7DMAC0180C2000008Localread-writecurrentNID Series card Port 7 L2CP Mode 0180C2000008 0: Forward 1: Discard 2: Peer
1.3.6.1.4.1.4756.20.500.20.1.1871ColumnnidL2CPPort7DMAC0180C2000009Localread-writecurrentNID Series card Port 7 L2CP Mode 0180C2000009 0: Forward 1: Discard 2: Peer
1.3.6.1.4.1.4756.20.500.20.1.1872ColumnnidL2CPPort7DMAC0180C200000ALocalread-writecurrentNID Series card Port 7 L2CP Mode 0180C200000A 0: Forward 1: Discard 2: Peer
1.3.6.1.4.1.4756.20.500.20.1.1873ColumnnidL2CPPort7DMAC0180C200000BLocalread-writecurrentNID Series card Port 7 L2CP Mode 0180C200000B 0: Forward 1: Discard 2: Peer
1.3.6.1.4.1.4756.20.500.20.1.1874ColumnnidL2CPPort7DMAC0180C200000CLocalread-writecurrentNID Series card Port 7 L2CP Mode 0180C200000C 0: Forward 1: Discard 2: Peer
1.3.6.1.4.1.4756.20.500.20.1.1875ColumnnidL2CPPort7DMAC0180C200000DLocalread-writecurrentNID Series card Port 7 L2CP Mode 0180C200000D 0: Forward 1: Discard 2: Peer
1.3.6.1.4.1.4756.20.500.20.1.1876ColumnnidL2CPPort7DMAC0180C200000ELocalread-writecurrentNID Series card Port 7 L2CP Mode 0180C200000E 0: Forward 1: Discard 2: Peer
1.3.6.1.4.1.4756.20.500.20.1.1877ColumnnidL2CPPort7DMAC0180C200000FLocalread-writecurrentNID Series card Port 7 L2CP Mode 0180C200000F 0: Forward 1: Discard 2: Peer
1.3.6.1.4.1.4756.20.500.20.1.1878ColumnnidL2CPPort7DMAC0180C2000010Localread-writecurrentNID Series card Port 7 L2CP Mode 0180C2000010 0: Forward 1: Discard 2: Peer
1.3.6.1.4.1.4756.20.500.20.1.1879ColumnnidL2CPPort7DMAC0180C2000020Localread-writecurrentNID Series card Port 7 L2CP Mode 0180C2000020 0: Forward 1: Discard 2: Peer
1.3.6.1.4.1.4756.20.500.20.1.1880ColumnnidL2CPPort7DMAC0180C2000021Localread-writecurrentNID Series card Port 7 L2CP Mode 0180C2000021 0: Forward 1: Discard 2: Peer
1.3.6.1.4.1.4756.20.500.20.1.1881ColumnnidL2CPPort7DMAC0180C2000022Localread-writecurrentNID Series card Port 7 L2CP Mode 0180C2000022 0: Forward 1: Discard 2: Peer
1.3.6.1.4.1.4756.20.500.20.1.1882ColumnnidL2CPPort7DMAC0180C2000023Localread-writecurrentNID Series card Port 7 L2CP Mode 0180C2000023 0: Forward 1: Discard 2: Peer
1.3.6.1.4.1.4756.20.500.20.1.1883ColumnnidL2CPPort7DMAC0180C2000024Localread-writecurrentNID Series card Port 7 L2CP Mode 0180C2000024 0: Forward 1: Discard 2: Peer
1.3.6.1.4.1.4756.20.500.20.1.1884ColumnnidL2CPPort7DMAC0180C2000025Localread-writecurrentNID Series card Port 7 L2CP Mode 0180C2000025 0: Forward 1: Discard 2: Peer
1.3.6.1.4.1.4756.20.500.20.1.1885ColumnnidL2CPPort7DMAC0180C2000026Localread-writecurrentNID Series card Port 7 L2CP Mode 0180C2000026 0: Forward 1: Discard 2: Peer
1.3.6.1.4.1.4756.20.500.20.1.1886ColumnnidL2CPPort7DMAC0180C2000027Localread-writecurrentNID Series card Port 7 L2CP Mode 0180C2000027 0: Forward 1: Discard 2: Peer
1.3.6.1.4.1.4756.20.500.20.1.1887ColumnnidL2CPPort7DMAC0180C2000028Localread-writecurrentNID Series card Port 7 L2CP Mode 0180C2000028 0: Forward 1: Discard 2: Peer
1.3.6.1.4.1.4756.20.500.20.1.1888ColumnnidL2CPPort7DMAC0180C2000029Localread-writecurrentNID Series card Port 7 L2CP Mode 0180C2000029 0: Forward 1: Discard 2: Peer
1.3.6.1.4.1.4756.20.500.20.1.1889ColumnnidL2CPPort7DMAC0180C200002ALocalread-writecurrentNID Series card Port 7 L2CP Mode 0180C200002A 0: Forward 1: Discard 2: Peer
1.3.6.1.4.1.4756.20.500.20.1.1890ColumnnidL2CPPort7DMAC0180C200002BLocalread-writecurrentNID Series card Port 7 L2CP Mode 0180C200002B 0: Forward 1: Discard 2: Peer
1.3.6.1.4.1.4756.20.500.20.1.1891ColumnnidL2CPPort7DMAC0180C200002CLocalread-writecurrentNID Series card Port 7 L2CP Mode 0180C200002C 0: Forward 1: Discard 2: Peer
1.3.6.1.4.1.4756.20.500.20.1.1892ColumnnidL2CPPort7DMAC0180C200002DLocalread-writecurrentNID Series card Port 7 L2CP Mode 0180C200002D 0: Forward 1: Discard 2: Peer
1.3.6.1.4.1.4756.20.500.20.1.1893ColumnnidL2CPPort7DMAC0180C200002ELocalread-writecurrentNID Series card Port 7 L2CP Mode 0180C200002E 0: Forward 1: Discard 2: Peer
1.3.6.1.4.1.4756.20.500.20.1.1894ColumnnidL2CPPort7DMAC0180C200002FLocalread-writecurrentNID Series card Port 7 L2CP Mode 0180C200002F 0: Forward 1: Discard 1: Peer
1.3.6.1.4.1.4756.20.500.20.1.1895ColumnnidL2CPPort8DMAC0180C2000000Localread-writecurrentNID Series card Port 8 L2CP Mode 0180C2000000 0: Forward 1: Discard 2: Peer
1.3.6.1.4.1.4756.20.500.20.1.1896ColumnnidL2CPPort8DMAC0180C2000001Localread-writecurrentNID Series card Port 8 L2CP Mode 0180C2000001 0: Forward 1: Discard 2: Peer
1.3.6.1.4.1.4756.20.500.20.1.1897ColumnnidL2CPPort8DMAC0180C2000002Localread-writecurrentNID Series card Port 8 L2CP Mode 0180C2000002 0: Forward 1: Discard 2: Peer
1.3.6.1.4.1.4756.20.500.20.1.1898ColumnnidL2CPPort8DMAC0180C2000003Localread-writecurrentNID Series card Port 8 L2CP Mode 0180C2000003 0: Forward 1: Discard 2: Peer
1.3.6.1.4.1.4756.20.500.20.1.1899ColumnnidL2CPPort8DMAC0180C2000004Localread-writecurrentNID Series card Port 8 L2CP Mode 0180C2000004 0: Forward 1: Discard 2: Peer
1.3.6.1.4.1.4756.20.500.20.1.1900ColumnnidL2CPPort8DMAC0180C2000005Localread-writecurrentNID Series card Port 8 L2CP Mode 0180C2000005 0: Forward 1: Discard 2: Peer
1.3.6.1.4.1.4756.20.500.20.1.1901ColumnnidL2CPPort8DMAC0180C2000006Localread-writecurrentNID Series card Port 8 L2CP Mode 0180C2000006 0: Forward 1: Discard 2: Peer
1.3.6.1.4.1.4756.20.500.20.1.1902ColumnnidL2CPPort8DMAC0180C2000007Localread-writecurrentNID Series card Port 8 L2CP Mode 0180C2000007 0: Forward 1: Discard 2: Peer
1.3.6.1.4.1.4756.20.500.20.1.1903ColumnnidL2CPPort8DMAC0180C2000008Localread-writecurrentNID Series card Port 8 L2CP Mode 0180C2000008 0: Forward 1: Discard 2: Peer
1.3.6.1.4.1.4756.20.500.20.1.1904ColumnnidL2CPPort8DMAC0180C2000009Localread-writecurrentNID Series card Port 8 L2CP Mode 0180C2000009 0: Forward 1: Discard 2: Peer
1.3.6.1.4.1.4756.20.500.20.1.1905ColumnnidL2CPPort8DMAC0180C200000ALocalread-writecurrentNID Series card Port 8 L2CP Mode 0180C200000A 0: Forward 1: Discard 2: Peer
1.3.6.1.4.1.4756.20.500.20.1.1906ColumnnidL2CPPort8DMAC0180C200000BLocalread-writecurrentNID Series card Port 8 L2CP Mode 0180C200000B 0: Forward 1: Discard 2: Peer
1.3.6.1.4.1.4756.20.500.20.1.1907ColumnnidL2CPPort8DMAC0180C200000CLocalread-writecurrentNID Series card Port 8 L2CP Mode 0180C200000C 0: Forward 1: Discard 2: Peer
1.3.6.1.4.1.4756.20.500.20.1.1908ColumnnidL2CPPort8DMAC0180C200000DLocalread-writecurrentNID Series card Port 8 L2CP Mode 0180C200000D 0: Forward 1: Discard 2: Peer
1.3.6.1.4.1.4756.20.500.20.1.1909ColumnnidL2CPPort8DMAC0180C200000ELocalread-writecurrentNID Series card Port 8 L2CP Mode 0180C200000E 0: Forward 1: Discard 2: Peer
1.3.6.1.4.1.4756.20.500.20.1.1910ColumnnidL2CPPort8DMAC0180C200000FLocalread-writecurrentNID Series card Port 8 L2CP Mode 0180C200000F 0: Forward 1: Discard 2: Peer
1.3.6.1.4.1.4756.20.500.20.1.1911ColumnnidL2CPPort8DMAC0180C2000010Localread-writecurrentNID Series card Port 8 L2CP Mode 0180C2000010 0: Forward 1: Discard 2: Peer
1.3.6.1.4.1.4756.20.500.20.1.1912ColumnnidL2CPPort8DMAC0180C2000020Localread-writecurrentNID Series card Port 8 L2CP Mode 0180C2000020 0: Forward 1: Discard 2: Peer
1.3.6.1.4.1.4756.20.500.20.1.1913ColumnnidL2CPPort8DMAC0180C2000021Localread-writecurrentNID Series card Port 8 L2CP Mode 0180C2000021 0: Forward 1: Discard 2: Peer
1.3.6.1.4.1.4756.20.500.20.1.1914ColumnnidL2CPPort8DMAC0180C2000022Localread-writecurrentNID Series card Port 8 L2CP Mode 0180C2000022 0: Forward 1: Discard 2: Peer
1.3.6.1.4.1.4756.20.500.20.1.1915ColumnnidL2CPPort8DMAC0180C2000023Localread-writecurrentNID Series card Port 8 L2CP Mode 0180C2000023 0: Forward 1: Discard 2: Peer
1.3.6.1.4.1.4756.20.500.20.1.1916ColumnnidL2CPPort8DMAC0180C2000024Localread-writecurrentNID Series card Port 8 L2CP Mode 0180C2000024 0: Forward 1: Discard 2: Peer
1.3.6.1.4.1.4756.20.500.20.1.1917ColumnnidL2CPPort8DMAC0180C2000025Localread-writecurrentNID Series card Port 8 L2CP Mode 0180C2000025 0: Forward 1: Discard 2: Peer
1.3.6.1.4.1.4756.20.500.20.1.1918ColumnnidL2CPPort8DMAC0180C2000026Localread-writecurrentNID Series card Port 8 L2CP Mode 0180C2000026 0: Forward 1: Discard 2: Peer
1.3.6.1.4.1.4756.20.500.20.1.1919ColumnnidL2CPPort8DMAC0180C2000027Localread-writecurrentNID Series card Port 8 L2CP Mode 0180C2000027 0: Forward 1: Discard 2: Peer
1.3.6.1.4.1.4756.20.500.20.1.1920ColumnnidL2CPPort8DMAC0180C2000028Localread-writecurrentNID Series card Port 8 L2CP Mode 0180C2000028 0: Forward 1: Discard 2: Peer
1.3.6.1.4.1.4756.20.500.20.1.1921ColumnnidL2CPPort8DMAC0180C2000029Localread-writecurrentNID Series card Port 8 L2CP Mode 0180C2000029 0: Forward 1: Discard 2: Peer
1.3.6.1.4.1.4756.20.500.20.1.1922ColumnnidL2CPPort8DMAC0180C200002ALocalread-writecurrentNID Series card Port 8 L2CP Mode 0180C200002A 0: Forward 1: Discard 2: Peer
1.3.6.1.4.1.4756.20.500.20.1.1923ColumnnidL2CPPort8DMAC0180C200002BLocalread-writecurrentNID Series card Port 8 L2CP Mode 0180C200002B 0: Forward 1: Discard 2: Peer
1.3.6.1.4.1.4756.20.500.20.1.1924ColumnnidL2CPPort8DMAC0180C200002CLocalread-writecurrentNID Series card Port 8 L2CP Mode 0180C200002C 0: Forward 1: Discard 2: Peer
1.3.6.1.4.1.4756.20.500.20.1.1925ColumnnidL2CPPort8DMAC0180C200002DLocalread-writecurrentNID Series card Port 8 L2CP Mode 0180C200002D 0: Forward 1: Discard 2: Peer
1.3.6.1.4.1.4756.20.500.20.1.1926ColumnnidL2CPPort8DMAC0180C200002ELocalread-writecurrentNID Series card Port 8 L2CP Mode 0180C200002E 0: Forward 1: Discard 2: Peer
1.3.6.1.4.1.4756.20.500.20.1.1927ColumnnidL2CPPort8DMAC0180C200002FLocalread-writecurrentNID Series card Port 8 L2CP Mode 0180C200002F 0: Forward 1: Discard 1: Peer
1.3.6.1.4.1.4756.20.500.20.1.1928ColumnnidFx1DDLocalread-onlycurrentNID Series card fiber port Digital Diagnostic function: 0:No 1:Yes
1.3.6.1.4.1.4756.20.500.20.1.1929ColumnnidFx1DDVendorLocalread-onlycurrentNID Series card fiber port D/D information: Vendor name
1.3.6.1.4.1.4756.20.500.20.1.1930ColumnnidFx1DDPartNoLocalread-onlycurrentNID Series card fiber port D/D information: Vendor part number
1.3.6.1.4.1.4756.20.500.20.1.1931ColumnnidFx1DDFiberTypeLocalread-onlycurrentNID Series card fiber port D/D information: Fiber Type
1.3.6.1.4.1.4756.20.500.20.1.1932ColumnnidFx1DDWaveLenLocalread-onlycurrentNID Series card fiber port D/D information: Wave length
1.3.6.1.4.1.4756.20.500.20.1.1933ColumnnidFx1DDWaveLen2Localread-onlycurrentNID Series card fiber port D/D information: Wave length 2
1.3.6.1.4.1.4756.20.500.20.1.1934ColumnnidFx1DDLinkLenLocalread-onlycurrentNID Series card fiber port D/D information: Link length
1.3.6.1.4.1.4756.20.500.20.1.1935ColumnnidFx1DDLenUnitLocalread-onlycurrentNID Series card fiber port D/D information: Length Unit
1.3.6.1.4.1.4756.20.500.20.1.1936ColumnnidFx1DDStatusLocalread-onlycurrentNID Series card fiber port D/D information: Status Support
1.3.6.1.4.1.4756.20.500.20.1.1937ColumnnidFx1DDRxSensLocalread-onlycurrentNID Series card fiber port D/D information: Rx Sensitivity
1.3.6.1.4.1.4756.20.500.20.1.1938ColumnnidFx1DDTxPWRLocalread-onlycurrentNID Series card fiber port D/D information: Tx power
1.3.6.1.4.1.4756.20.500.20.1.1939ColumnnidFx1DDRxPWRLocalread-onlycurrentNID Series card fiber port D/D information: Rx power
1.3.6.1.4.1.4756.20.500.20.1.1940ColumnnidFx1DDTempLocalread-onlycurrentNID Series card fiber port D/D information: Temperature in degree C
1.3.6.1.4.1.4756.20.500.20.1.1941ColumnnidFx1DDPWRMarginLocalread-onlycurrentNID Series card fiber port D/D information: Power margin
1.3.6.1.4.1.4756.20.500.20.1.1942ColumnnidFx1DDPWRLossLocalread-onlycurrentNID Series card fiber port D/D information: Power loss
1.3.6.1.4.1.4756.20.500.20.1.1943ColumnnidFx2DDLocalread-onlycurrentNID Series card fiber2 Digital Diagnostic function: 0:NO 1:Yes
1.3.6.1.4.1.4756.20.500.20.1.1944ColumnnidFx2DDVendorLocalread-onlycurrentNID Series card fiber2 D/D information: Vendor name
1.3.6.1.4.1.4756.20.500.20.1.1945ColumnnidFx2DDPartNoLocalread-onlycurrentNID Series card fiber2 D/D information: Vendor part number
1.3.6.1.4.1.4756.20.500.20.1.1946ColumnnidFx2DDFiberTypeLocalread-onlycurrentNID Series card fiber2 D/D information: Fiber Type
1.3.6.1.4.1.4756.20.500.20.1.1947ColumnnidFx2DDWaveLenLocalread-onlycurrentNID Series card fiber2 D/D information: Wave length 1
1.3.6.1.4.1.4756.20.500.20.1.1948ColumnnidFx2DDWaveLen2Localread-onlycurrentNID Series card fiber2 D/D information: Wave length 2
1.3.6.1.4.1.4756.20.500.20.1.1949ColumnnidFx2DDLinkLenLocalread-onlycurrentNID Series card fiber2 D/D information: Link length
1.3.6.1.4.1.4756.20.500.20.1.1950ColumnnidFx2DDLenUnitLocalread-onlycurrentNID Series card fiber2 D/D information: Length Unit
1.3.6.1.4.1.4756.20.500.20.1.1951ColumnnidFx2DDStatusLocalread-onlycurrentNID Series card fiber2 D/D information: Status Support
1.3.6.1.4.1.4756.20.500.20.1.1952ColumnnidFx2DDRxSensLocalread-onlycurrentNID Series card fiber2 D/D information: Rx Sensitivity
1.3.6.1.4.1.4756.20.500.20.1.1953ColumnnidFx2DDTxPWRLocalread-onlycurrentNID Series card fiber2 D/D information: Tx power
1.3.6.1.4.1.4756.20.500.20.1.1954ColumnnidFx2DDRxPWRLocalread-onlycurrentNID Series card fiber2 D/D information: Rx power
1.3.6.1.4.1.4756.20.500.20.1.1955ColumnnidFx2DDTempLocalread-onlycurrentNID Series card fiber2 D/D information: Temperature in degree C
1.3.6.1.4.1.4756.20.500.20.1.1956ColumnnidFx2DDPWRMarginLocalread-onlycurrentNID Series card fiber2 D/D information: Power margin
1.3.6.1.4.1.4756.20.500.20.1.1957ColumnnidFx2DDPWRLossLocalread-onlycurrentNID Series card fiber2 D/D information: Power loss
1.3.6.1.4.1.4756.20.500.20.1.1958ColumnnidFx3DDLocalread-onlycurrentNID Series card fiber3 Digital Diagnostic function: 0:NO 1:Yes
1.3.6.1.4.1.4756.20.500.20.1.1959ColumnnidFx3DDVendorLocalread-onlycurrentNID Series card fiber3 D/D information: Vendor name
1.3.6.1.4.1.4756.20.500.20.1.1960ColumnnidFx3DDPartNoLocalread-onlycurrentNID Series card fiber32 D/D information: Vendor part number
1.3.6.1.4.1.4756.20.500.20.1.1961ColumnnidFx3DDFiberTypeLocalread-onlycurrentNID Series card fiber3 D/D information: Fiber Type
1.3.6.1.4.1.4756.20.500.20.1.1962ColumnnidFx3DDWaveLenLocalread-onlycurrentNID Series card fiber3 D/D information: Wave length 1
1.3.6.1.4.1.4756.20.500.20.1.1963ColumnnidFx3DDWaveLen2Localread-onlycurrentNID Series card fiber3 D/D information: Wave length 2
1.3.6.1.4.1.4756.20.500.20.1.1964ColumnnidFx3DDLinkLenLocalread-onlycurrentNID Series card fiber3 D/D information: Link length
1.3.6.1.4.1.4756.20.500.20.1.1965ColumnnidFx3DDLenUnitLocalread-onlycurrentNID Series card fiber3 D/D information: Length Unit
1.3.6.1.4.1.4756.20.500.20.1.1966ColumnnidFx3DDStatusLocalread-onlycurrentNID Series card fiber3 D/D information: Status Support
1.3.6.1.4.1.4756.20.500.20.1.1967ColumnnidFx3DDRxSensLocalread-onlycurrentNID Series card fiber3 D/D information: Rx Sensitivity
1.3.6.1.4.1.4756.20.500.20.1.1968ColumnnidFx3DDTxPWRLocalread-onlycurrentNID Series card fiber3 D/D information: Tx power
1.3.6.1.4.1.4756.20.500.20.1.1969ColumnnidFx3DDRxPWRLocalread-onlycurrentNID Series card fiber3 D/D information: Rx power
1.3.6.1.4.1.4756.20.500.20.1.1970ColumnnidFx3DDTempLocalread-onlycurrentNID Series card fiber3 D/D information: Temperature in degree C
1.3.6.1.4.1.4756.20.500.20.1.1971ColumnnidFx3DDPWRMarginLocalread-onlycurrentNID Series card fiber3 D/D information: Power margin
1.3.6.1.4.1.4756.20.500.20.1.1972ColumnnidFx3DDPWRLossLocalread-onlycurrentNID Series card fiber3 D/D information: Power loss
1.3.6.1.4.1.4756.20.500.20.1.1973ColumnnidFx4DDLocalread-onlycurrentNID Series card fiber4 Digital Diagnostic function: 0:NO 1:Yes
1.3.6.1.4.1.4756.20.500.20.1.1974ColumnnidFx4DDVendorLocalread-onlycurrentNID Series card fiber4 D/D information: Vendor name
1.3.6.1.4.1.4756.20.500.20.1.1975ColumnnidFx4DDPartNoLocalread-onlycurrentNID Series card fiber4 D/D information: Vendor part number
1.3.6.1.4.1.4756.20.500.20.1.1976ColumnnidFx4DDFiberTypeLocalread-onlycurrentNID Series card fiber4 D/D information: Fiber Type
1.3.6.1.4.1.4756.20.500.20.1.1977ColumnnidFx4DDWaveLenLocalread-onlycurrentNID Series card fiber4 D/D information: Wave length 1
1.3.6.1.4.1.4756.20.500.20.1.1978ColumnnidFx4DDWaveLen2Localread-onlycurrentNID Series card fiber4 D/D information: Wave length 2
1.3.6.1.4.1.4756.20.500.20.1.1979ColumnnidFx4DDLinkLenLocalread-onlycurrentNID Series card fiber4 D/D information: Link length
1.3.6.1.4.1.4756.20.500.20.1.1980ColumnnidFx4DDLenUnitLocalread-onlycurrentNID Series card fiber4 D/D information: Length Unit
1.3.6.1.4.1.4756.20.500.20.1.1981ColumnnidFx4DDStatusLocalread-onlycurrentNID Series card fiber4 D/D information: Status Support
1.3.6.1.4.1.4756.20.500.20.1.1982ColumnnidFx4DDRxSensLocalread-onlycurrentNID Series card fiber4 D/D information: Rx Sensitivity
1.3.6.1.4.1.4756.20.500.20.1.1983ColumnnidFx4DDTxPWRLocalread-onlycurrentNID Series card fiber4 D/D information: Tx power
1.3.6.1.4.1.4756.20.500.20.1.1984ColumnnidFx4DDRxPWRLocalread-onlycurrentNID Series card fiber4 D/D information: Rx power
1.3.6.1.4.1.4756.20.500.20.1.1985ColumnnidFx4DDTempLocalread-onlycurrentNID Series card fiber4 D/D information: Temperature in degree C
1.3.6.1.4.1.4756.20.500.20.1.1986ColumnnidFx4DDPWRMarginLocalread-onlycurrentNID Series card fiber4 D/D information: Power margin
1.3.6.1.4.1.4756.20.500.20.1.1987ColumnnidFx4DDPWRLossLocalread-onlycurrentNID Series card fiber4 D/D information: Power loss
1.3.6.1.4.1.4756.20.500.20.1.1988ColumnnidDeviceActiveLocalread-writecurrentNID Series card u-Ring device active 0: Disable 1: Enable
1.3.6.1.4.1.4756.20.500.20.1.1989ColumnnidSaveStartupCongLocalread-writecurrentNID Series card save start-up config 0: OFF 1: Action
1.3.6.1.4.1.4756.20.500.20.1.1990ColumnnidPortResetLocalread-writecurrentNID Series card port reset 0: OFF 1: Action
1.3.6.1.4.1.4756.20.500.20.1.1991ColumnnidSetDefaultLocalread-writecurrentNID Series card set to default config 0: OFF 1: Action
1.3.6.1.4.1.4756.20.500.20.1.1992ColumnnidSetDefault2Localread-writecurrentNID Series card set to default config (Without OAM) 0: OFF 1: Action
1.3.6.1.4.1.4756.20.500.20.1.1993ColumnnidClearPortCounterLocalread-writecurrentNID Series card clear port counter: 0: Off 1: Action
1.3.6.1.4.1.4756.20.500.20.1.1994ColumnnidClearOAMCounterLocalread-writecurrentNID Series card Clear OAM Counter: 0: Off 1: Action
1.3.6.1.4.1.4756.20.500.20.1.1995ColumnnidSTPStatisticsPortClearCounterLocalread-writecurrentNID Series card STP Port Statistics: Clear Counters 0: OFff 1: Action
1.3.6.1.4.1.4756.20.500.20.1.1996ColumnnidAlarmLocalread-onlycurrentNID Series card Alarm led status: 0: Off 1: On
1.3.6.1.4.1.4756.20.500.20.1.1997ColumnnidTest1Localread-onlycurrentNID Series card Test1 led status: 0: Off 1: On
1.3.6.1.4.1.4756.20.500.20.1.1998ColumnnidTest2Localread-onlycurrentNID Series card Test2 led status: 0: Off 1: On
1.3.6.1.4.1.4756.20.501NodenidRemoteACards
1.3.6.1.4.1.4756.20.501.20TablenidRemoteATablenot-accessiblecurrentA list of RemoteA FRM220-MSW404/MSW404S card entries. The number of entries is f16G3R-No-L.
1.3.6.1.4.1.4756.20.501.20.1RownidRemoteAEntrynot-accessiblecurrentAn entry containing management information applicable to a particular RemoteA FRM220-MSW404/MSW404S card.
1.3.6.1.4.1.4756.20.501.20.1.1ColumnnidChassisIndexRemoteAread-onlycurrentA unique value for each RemoteA card. It is the chassis location number.
1.3.6.1.4.1.4756.20.501.20.1.2ColumnnidSlotIndexRemoteAread-onlycurrentA unique value for each RemoteA card. It is the slot location number.
1.3.6.1.4.1.4756.20.501.20.1.3ColumnnidCardHWVerRemoteAread-onlycurrentRemoteA NID card hardware version x.xxx
1.3.6.1.4.1.4756.20.501.20.1.4ColumnnidCardFWVerRemoteAread-onlycurrentRemoteA NID card firmware version x.xxx
1.3.6.1.4.1.4756.20.501.20.1.5ColumnnidCardCPLDVerRemoteAread-onlycurrentRemoteA NID card CPLD version x.xxx
1.3.6.1.4.1.4756.20.501.20.1.6ColumnnidCardFPGAVerRemoteAread-onlycurrentRemoteA NID card FPGA version x.xxx
1.3.6.1.4.1.4756.20.501.20.1.7ColumnnidModelRemoteAread-onlycurrentCard Type: 0:MSW404 1:MSW404S
1.3.6.1.4.1.4756.20.501.20.1.8ColumnnidDNSServerTypeRemoteAread-writecurrentNID Series card IP Configuration: This setting controls the DNS name resolution done by the switch. The following modes are supported: 1:From any DHCP interfac…
1.3.6.1.4.1.4756.20.501.20.1.9ColumnnidDNSServerSettingRemoteAread-writecurrentNID Series card IP Configuration: If iDNSServerType setting '3:Configured',this value must setting IP address format as below: Dotted Decimal Notation refers t…
1.3.6.1.4.1.4756.20.501.20.1.10ColumnnidDNSproxyRemoteAread-writecurrentNID Series card IP Configuration: When DNS proxy is enabled, system will relay DNS requests to the currently configured DNS server, and reply as a DNS resolver…
1.3.6.1.4.1.4756.20.501.20.1.11ColumnnidAddIPV4InterfaceRemoteAread-writecurrentNID Series card IP Interfaces: Add a new IP VLAN Interface: Syntax: [<Interface>] [<vlan_list>] [<IPV4_Addr>] [<IPV4_MASK>] Interface : 1~4
1.3.6.1.4.1.4756.20.501.20.1.12ColumnnidDeleteInterfaceRemoteAread-writecurrentNID Series card IP Interfaces: Delete a IPv4/v6 VLAN Interface: Syntax: [<Interface>] Interface: 1~4
1.3.6.1.4.1.4756.20.501.20.1.13ColumnnidIPInterface1VLANRemoteAread-onlycurrentNID Series card IP Interfaces: The VLAN associated with the IP interface. Only ports in this VLAN will be able to access the IP interface. This field is only a…
1.3.6.1.4.1.4756.20.501.20.1.14ColumnnidIPInterface1DHCPRemoteAread-writecurrentNID Series card IP Interfaces: DHCP
1.3.6.1.4.1.4756.20.501.20.1.15ColumnnidIPInterface1FallbackRemoteAread-writecurrentNID Series card IP Interfaces: Fallback
1.3.6.1.4.1.4756.20.501.20.1.16ColumnnidIPInterface1IPV4AddressRemoteAread-onlycurrentNID Series card IP Interfaces: IPV4 Address
1.3.6.1.4.1.4756.20.501.20.1.17ColumnnidIPInterface1IPV4MASKLenRemoteAread-onlycurrentNID Series card IP Interfaces: IPV4 MASK Length
1.3.6.1.4.1.4756.20.501.20.1.18ColumnnidIPInterface2VLANRemoteAread-onlycurrentNID Series card IP Interfaces: The VLAN associated with the IP interface. Only ports in this VLAN will be able to access the IP interface. This field is only a…
1.3.6.1.4.1.4756.20.501.20.1.19ColumnnidIPInterface2DHCPRemoteAread-writecurrentNID Series card IP Interfaces: DHCP
1.3.6.1.4.1.4756.20.501.20.1.20ColumnnidIPInterface2FallbackRemoteAread-writecurrentNID Series card IP Interfaces: Fallback
1.3.6.1.4.1.4756.20.501.20.1.21ColumnnidIPInterface2IPV4AddressRemoteAread-onlycurrentNID Series card IP Interfaces: IPV4 Address
1.3.6.1.4.1.4756.20.501.20.1.22ColumnnidIPInterface2IPV4MASKLenRemoteAread-onlycurrentNID Series card IP Interfaces: IPV4 MASK Length
1.3.6.1.4.1.4756.20.501.20.1.23ColumnnidIPInterface3VLANRemoteAread-onlycurrentNID Series card IP Interfaces: The VLAN associated with the IP interface. Only ports in this VLAN will be able to access the IP interface. This field is only a…
1.3.6.1.4.1.4756.20.501.20.1.24ColumnnidIPInterface3DHCPRemoteAread-writecurrentNID Series card IP Interfaces: DHCP
1.3.6.1.4.1.4756.20.501.20.1.25ColumnnidIPInterface3FallbackRemoteAread-writecurrentNID Series card IP Interfaces: Fallback
1.3.6.1.4.1.4756.20.501.20.1.26ColumnnidIPInterface3IPV4AddressRemoteAread-onlycurrentNID Series card IP Interfaces: IPV4 Address
1.3.6.1.4.1.4756.20.501.20.1.27ColumnnidIPInterface3IPV4MASKLenRemoteAread-onlycurrentNID Series card IP Interfaces: IPV4 MASK Length
1.3.6.1.4.1.4756.20.501.20.1.28ColumnnidIPInterface4VLANRemoteAread-onlycurrentNID Series card IP Interfaces: The VLAN associated with the IP interface. Only ports in this VLAN will be able to access the IP interface. This field is only a…
1.3.6.1.4.1.4756.20.501.20.1.29ColumnnidIPInterface4DHCPRemoteAread-writecurrentNID Series card IP Interfaces: DHCP
1.3.6.1.4.1.4756.20.501.20.1.30ColumnnidIPInterface4FallbackRemoteAread-writecurrentNID Series card IP Interfaces: Fallback
1.3.6.1.4.1.4756.20.501.20.1.31ColumnnidIPInterface4IPV4AddressRemoteAread-onlycurrentNID Series card IP Interfaces: IPV4 Address
1.3.6.1.4.1.4756.20.501.20.1.32ColumnnidIPInterface4IPV4MASKLenRemoteAread-onlycurrentNID Series card IP Interfaces: IPV4 MASK Length
1.3.6.1.4.1.4756.20.501.20.1.33ColumnnidAddIPV6InterfaceRemoteAread-writecurrentNID Series card IP Interfaces: Add a new IPv6 VLAN Interface: Syntax: [<Interface>] [<vlan_list>] [<IPV4_Addr>] [<IPV4_MASK>] Interface : 1~4
1.3.6.1.4.1.4756.20.501.20.1.34ColumnnidIPInterface1IPV6AddressRemoteAread-onlycurrentNID Series card IP Interfaces: IPV6 Address
1.3.6.1.4.1.4756.20.501.20.1.35ColumnnidIPInterface1IPV6MASKLenRemoteAread-onlycurrentNID Series card IP Interfaces: IPV6 MASK Length
1.3.6.1.4.1.4756.20.501.20.1.36ColumnnidIPInterface2IPV6AddressRemoteAread-onlycurrentNID Series card IP Interfaces: IPV6 Address
1.3.6.1.4.1.4756.20.501.20.1.37ColumnnidIPInterface2IPV6MASKLenRemoteAread-onlycurrentNID Series card IP Interfaces: IPV6 MASK Length
1.3.6.1.4.1.4756.20.501.20.1.38ColumnnidIPInterface3IPV6AddressRemoteAread-onlycurrentNID Series card IP Interfaces: IPV6 Address
1.3.6.1.4.1.4756.20.501.20.1.39ColumnnidIPInterface3IPV6MASKLenRemoteAread-onlycurrentNID Series card IP Interfaces: IPV6 MASK Length
1.3.6.1.4.1.4756.20.501.20.1.40ColumnnidIPInterface4IPV6AddressRemoteAread-onlycurrentNID Series card IP Interfaces: IPV6 Address
1.3.6.1.4.1.4756.20.501.20.1.41ColumnnidIPInterface4IPV6MASKLenRemoteAread-onlycurrentNID Series card IP Interfaces: IPV6 MASK Length
1.3.6.1.4.1.4756.20.501.20.1.42ColumnnidPort1LinkstsRemoteAread-onlycurrentNID Series card Port1 link status: 0:Link down 1:Link up
1.3.6.1.4.1.4756.20.501.20.1.43ColumnnidPort1SpeedstsRemoteAread-onlycurrentNID Series card Port1 speed status 10Base-T 100Base-Tx 1000Base-Tx 2.5G
1.3.6.1.4.1.4756.20.501.20.1.44ColumnnidPort1DuplexstsRemoteAread-onlycurrentNID Series card Port1 duplex status 0: Half 1: Full
1.3.6.1.4.1.4756.20.501.20.1.45ColumnnidPort1RxPausestsRemoteAread-onlycurrentNID Series card Port1 rx pause status 0: No 1: Yes
1.3.6.1.4.1.4756.20.501.20.1.46ColumnnidPort1TxPausestsRemoteAread-onlycurrentNID Series card Port1 tx pause status 0: No 1: Yes
1.3.6.1.4.1.4756.20.501.20.1.47ColumnnidPort2LinkstsRemoteAread-onlycurrentNID Series card Port2 link status: 0:Link down 1:Link up
1.3.6.1.4.1.4756.20.501.20.1.48ColumnnidPort2SpeedstsRemoteAread-onlycurrentNID Series card Port2 speed status 10Base-T 100Base-Tx 1000Base-Tx 2.5G
1.3.6.1.4.1.4756.20.501.20.1.49ColumnnidPort2DuplexstsRemoteAread-onlycurrentNID Series card Port2 duplex status 0: Half 1: Full
1.3.6.1.4.1.4756.20.501.20.1.50ColumnnidPort2RxPausestsRemoteAread-onlycurrentNID Series card Port2 rx pause status 0: No 1: Yes
1.3.6.1.4.1.4756.20.501.20.1.51ColumnnidPort2TxPausestsRemoteAread-onlycurrentNID Series card Port2 tx pause status 0: No 1: Yes
1.3.6.1.4.1.4756.20.501.20.1.52ColumnnidPort3LinkstsRemoteAread-onlycurrentNID Series card Port3 link status: 0:Link down 1:Link up
1.3.6.1.4.1.4756.20.501.20.1.53ColumnnidPort3SpeedstsRemoteAread-onlycurrentNID Series card Port3 speed status 10Base-T 100Base-Tx 1000Base-Tx
1.3.6.1.4.1.4756.20.501.20.1.54ColumnnidPort3DuplexstsRemoteAread-onlycurrentNID Series card Port3 duplex status 0: Half 1: Full
1.3.6.1.4.1.4756.20.501.20.1.55ColumnnidPort3RxPausestsRemoteAread-onlycurrentNID Series card Port3 rx pause status 0: No 1: Yes
1.3.6.1.4.1.4756.20.501.20.1.56ColumnnidPort3TxPausestsRemoteAread-onlycurrentNID Series card Port3 tx pause status 0: No 1: Yes
1.3.6.1.4.1.4756.20.501.20.1.57ColumnnidPort4LinkstsRemoteAread-onlycurrentNID Series card Port4 link status: 0:Link down 1:Link up
1.3.6.1.4.1.4756.20.501.20.1.58ColumnnidPort4SpeedstsRemoteAread-onlycurrentNID Series card Port4 speed status 10Base-T 100Base-Tx 1000Base-Tx
1.3.6.1.4.1.4756.20.501.20.1.59ColumnnidPort4DuplexstsRemoteAread-onlycurrentNID Series card Port4 duplex status 0: Half 1: Full
1.3.6.1.4.1.4756.20.501.20.1.60ColumnnidPort4RxPausestsRemoteAread-onlycurrentNID Series card Port4 rx pause status 0: No 1: Yes
1.3.6.1.4.1.4756.20.501.20.1.61ColumnnidPort4TxPausestsRemoteAread-onlycurrentNID Series card Port4 tx pause status 0: No 1: Yes
1.3.6.1.4.1.4756.20.501.20.1.62ColumnnidPort5LinkstsRemoteAread-onlycurrentNID Series card Port5 link status: 0:Link down 1:Link up
1.3.6.1.4.1.4756.20.501.20.1.63ColumnnidPort5SpeedstsRemoteAread-onlycurrentNID Series card Port5 speed status 10Base-T 100Base-Tx 1000Base-Tx
1.3.6.1.4.1.4756.20.501.20.1.64ColumnnidPort5DuplexstsRemoteAread-onlycurrentNID Series card Port5 duplex status 0: Half 1: Full
1.3.6.1.4.1.4756.20.501.20.1.65ColumnnidPort5RxPausestsRemoteAread-onlycurrentNID Series card Port5 rx pause status 0: No 1: Yes
1.3.6.1.4.1.4756.20.501.20.1.66ColumnnidPort5TxPausestsRemoteAread-onlycurrentNID Series card Port5 tx pause status 0: No 1: Yes
1.3.6.1.4.1.4756.20.501.20.1.67ColumnnidPort6LinkstsRemoteAread-onlycurrentNID Series card Port6 link status: 0:Link down 1:Link up
1.3.6.1.4.1.4756.20.501.20.1.68ColumnnidPort6SpeedstsRemoteAread-onlycurrentNID Series card Port6 speed status 10Base-T 100Base-Tx 1000Base-Tx
1.3.6.1.4.1.4756.20.501.20.1.69ColumnnidPort6DuplexstsRemoteAread-onlycurrentNID Series card Port6 duplex status 0: Half 1: Full
1.3.6.1.4.1.4756.20.501.20.1.70ColumnnidPort6RxPausestsRemoteAread-onlycurrentNID Series card Port6 rx pause status 0: No 1: Yes
1.3.6.1.4.1.4756.20.501.20.1.71ColumnnidPort6TxPausestsRemoteAread-onlycurrentNID Series card Port6 tx pause status 0: No 1: Yes
1.3.6.1.4.1.4756.20.501.20.1.72ColumnnidPort7LinkstsRemoteAread-onlycurrentNID Series card Port7 link status: 0:Link down 1:Link up
1.3.6.1.4.1.4756.20.501.20.1.73ColumnnidPort7SpeedstsRemoteAread-onlycurrentNID Series card Port7 speed status 10Base-T 100Base-Tx 1000Base-Tx
1.3.6.1.4.1.4756.20.501.20.1.74ColumnnidPort7DuplexstsRemoteAread-onlycurrentNID Series card Port7 duplex status 0: Half 1: Full
1.3.6.1.4.1.4756.20.501.20.1.75ColumnnidPort7RxPausestsRemoteAread-onlycurrentNID Series card Port7 rx pause status 0: No 1: Yes
1.3.6.1.4.1.4756.20.501.20.1.76ColumnnidPort7TxPausestsRemoteAread-onlycurrentNID Series card Port7 tx pause status 0: No 1: Yes
1.3.6.1.4.1.4756.20.501.20.1.77ColumnnidPort8LinkstsRemoteAread-onlycurrentNID Series card Port8 link status: 0:Link down 1:Link up
1.3.6.1.4.1.4756.20.501.20.1.78ColumnnidPort8SpeedstsRemoteAread-onlycurrentNID Series card Port8 speed status 10Base-T 100Base-Tx 1000Base-Tx
1.3.6.1.4.1.4756.20.501.20.1.79ColumnnidPort8DuplexstsRemoteAread-onlycurrentNID Series card Port8 duplex status 0: Half 1: Full
1.3.6.1.4.1.4756.20.501.20.1.80ColumnnidPort8RxPausestsRemoteAread-onlycurrentNID Series card Port8 rx pause status 0: No 1: Yes
1.3.6.1.4.1.4756.20.501.20.1.81ColumnnidPort8TxPausestsRemoteAread-onlycurrentNID Series card Port8 tx pause status 0: No 1: Yes
1.3.6.1.4.1.4756.20.501.20.1.82ColumnnidPort1SpeedConfRemoteAread-writecurrentNID Series card Port1 speed config 0: disable 1: auto 2: 100M FDX 3: 1G FDX 4: 2.5G FDX
1.3.6.1.4.1.4756.20.501.20.1.83ColumnnidPort1flowConrolRemoteAread-writecurrentNID Series card Port1 flow control config 0: no 1: yes
1.3.6.1.4.1.4756.20.501.20.1.84ColumnnidPort1MaxFrameRemoteAread-writecurrentNID Series card Port1 max frame config
1.3.6.1.4.1.4756.20.501.20.1.85ColumnnidPort1ALSRemoteAread-writecurrentNID Series card Port1 auto laser shutdown: 0: Disable 1: Enable
1.3.6.1.4.1.4756.20.501.20.1.86ColumnnidPort2SpeedConfRemoteAread-writecurrentNID Series card Port2 speed config 0: disable 1: auto 2: 100M FDX 3: 1G FDX 4: 2.5G FDX
1.3.6.1.4.1.4756.20.501.20.1.87ColumnnidPort2flowConrolRemoteAread-writecurrentNID Series card Port2 flow control config 0: no 1: yes
1.3.6.1.4.1.4756.20.501.20.1.88ColumnnidPort2MaxFrameRemoteAread-writecurrentNID Series card Port2 max frame config
1.3.6.1.4.1.4756.20.501.20.1.89ColumnnidPort2ALSRemoteAread-writecurrentNID Series card Port2 auto laser shutdown: 0: Disable 1: Enable
1.3.6.1.4.1.4756.20.501.20.1.90ColumnnidPort3SpeedConfRemoteAread-writecurrentNID Series card Port3 speed config 0: disable 1: auto 2: 100M FDX 3: 1G FDX
1.3.6.1.4.1.4756.20.501.20.1.91ColumnnidPort3flowConrolRemoteAread-writecurrentNID Series card Port3 flow control config 0: no 1: yes
1.3.6.1.4.1.4756.20.501.20.1.92ColumnnidPort3MaxFrameRemoteAread-writecurrentNID Series card Port3 max frame config
1.3.6.1.4.1.4756.20.501.20.1.93ColumnnidPort3ALSRemoteAread-writecurrentNID Series card Port3 auto laser shutdown: 0: Disable 1: Enable
1.3.6.1.4.1.4756.20.501.20.1.94ColumnnidPort4SpeedConfRemoteAread-writecurrentNID Series card Port4 speed config 0: disable 1: auto 2: 100M FDX 3: 1G FDX
1.3.6.1.4.1.4756.20.501.20.1.95ColumnnidPort4flowConrolRemoteAread-writecurrentNID Series card Port4 flow control config 0: no 1: yes
1.3.6.1.4.1.4756.20.501.20.1.96ColumnnidPort4MaxFrameRemoteAread-writecurrentNID Series card Port4 max frame config
1.3.6.1.4.1.4756.20.501.20.1.97ColumnnidPort4ALSRemoteAread-writecurrentNID Series card Port4 auto laser shutdown: 0: Disable 1: Enable
1.3.6.1.4.1.4756.20.501.20.1.98ColumnnidPort5SpeedConfRemoteAread-writecurrentNID Series card Port5 speed config 0: disable 1: auto 2: 10M HDX 3: 10M FDX 4: 100M HDX 5: 100M FDX 6: 1G FDX
1.3.6.1.4.1.4756.20.501.20.1.99ColumnnidPort5flowConrolRemoteAread-writecurrentNID Series card Port5 flow control config 0: no 1: yes
1.3.6.1.4.1.4756.20.501.20.1.100ColumnnidPort5MaxFrameRemoteAread-writecurrentNID Series card Port5 max frame config
1.3.6.1.4.1.4756.20.501.20.1.101ColumnnidPort5CollisionModeRemoteAread-writecurrentNID Series card Port5 collision mode config. 0: Discard 1: Restart
1.3.6.1.4.1.4756.20.501.20.1.102ColumnnidPort6SpeedConfRemoteAread-writecurrentNID Series card Port6 speed config 0: disable 1: auto 2: 10M HDX 3: 10M FDX 4: 100M HDX 5: 100M FDX 6: 1G FDX
1.3.6.1.4.1.4756.20.501.20.1.103ColumnnidPort6flowConrolRemoteAread-writecurrentNID Series card Port6 flow control config 0: no 1: yes
1.3.6.1.4.1.4756.20.501.20.1.104ColumnnidPort6MaxFrameRemoteAread-writecurrentNID Series card Port6 max frame config
1.3.6.1.4.1.4756.20.501.20.1.105ColumnnidPort6CollisionModeRemoteAread-writecurrentNID Series card Port6 collision mode config. 0: Discard 1: Restart
1.3.6.1.4.1.4756.20.501.20.1.106ColumnnidPort7SpeedConfRemoteAread-writecurrentNID Series card Port7 speed config 0: disable 1: auto 2: 10M HDX 3: 10M FDX 4: 100M HDX 5: 100M FDX 6: 1G FDX
1.3.6.1.4.1.4756.20.501.20.1.107ColumnnidPort7flowConrolRemoteAread-writecurrentNID Series card Port7 flow control config 0: no 1: yes
1.3.6.1.4.1.4756.20.501.20.1.108ColumnnidPort7MaxFrameRemoteAread-writecurrentNID Series card Port7 max frame config
1.3.6.1.4.1.4756.20.501.20.1.109ColumnnidPort7CollisionModeRemoteAread-writecurrentNID Series card Port7 collision mode config. 0: Discard 1: Restart
1.3.6.1.4.1.4756.20.501.20.1.110ColumnnidPort8SpeedConfRemoteAread-writecurrentNID Series card Port8 speed config 0: disable 1: auto 2: 10M HDX 3: 10M FDX 4: 100M HDX 5: 100M FDX 6: 1G FDX
1.3.6.1.4.1.4756.20.501.20.1.111ColumnnidPort8flowConrolRemoteAread-writecurrentNID Series card Port8 flow control config 0: no 1: yes
1.3.6.1.4.1.4756.20.501.20.1.112ColumnnidPort8MaxFrameRemoteAread-writecurrentNID Series card Port8 max frame config
1.3.6.1.4.1.4756.20.501.20.1.113ColumnnidPort8CollisionModeRemoteAread-writecurrentNID Series card Port8 collision mode config. 0: Discard 1: Restart
1.3.6.1.4.1.4756.20.501.20.1.114ColumnnidPort1LLFLogicRemoteAread-writecurrentNID Series card Port1 link loss forwarding - Logic 0: AND 1: OR
1.3.6.1.4.1.4756.20.501.20.1.115ColumnnidPort1LLFLogicPort2RemoteAread-writecurrentNID Series card Port1 link loss forwarding - Link/Rx Loss Port2 0: NO 1: YES
1.3.6.1.4.1.4756.20.501.20.1.116ColumnnidPort1LLFLogicPort3RemoteAread-writecurrentNID Series card Port1 link loss forwarding - Link/Rx Loss Port3 0: NO 1: YES
1.3.6.1.4.1.4756.20.501.20.1.117ColumnnidPort1LLFLogicPort4RemoteAread-writecurrentNID Series card Port1 link loss forwarding - Link/Rx Loss Port4 0: NO 1: YES
1.3.6.1.4.1.4756.20.501.20.1.118ColumnnidPort1LLFLogicPort5RemoteAread-writecurrentNID Series card Port1 link loss forwarding - Link/Rx Loss Port5 0: NO 1: YES
1.3.6.1.4.1.4756.20.501.20.1.119ColumnnidPort1LLFLogicPort6RemoteAread-writecurrentNID Series card Port1 link loss forwarding - Link/Rx Loss Port6 0: NO 1: YES
1.3.6.1.4.1.4756.20.501.20.1.120ColumnnidPort1LLFLogicPort7RemoteAread-writecurrentNID Series card Port1 link loss forwarding - Link/Rx Loss Port7 0: NO 1: YES
1.3.6.1.4.1.4756.20.501.20.1.121ColumnnidPort1LLFLogicPort8RemoteAread-writecurrentNID Series card Port1 link loss forwarding - Link/Rx Loss Port8 0: NO 1: YES
1.3.6.1.4.1.4756.20.501.20.1.122ColumnnidPort2LLFLogicRemoteAread-writecurrentNID Series card Port2 link loss forwarding - Logic 0: AND 1: OR
1.3.6.1.4.1.4756.20.501.20.1.123ColumnnidPort2LLFLogicPort1RemoteAread-writecurrentNID Series card Port2 link loss forwarding - Link/Rx Loss Port1 0: NO 1: YES
1.3.6.1.4.1.4756.20.501.20.1.124ColumnnidPort2LLFLogicPort3RemoteAread-writecurrentNID Series card Port2 link loss forwarding - Link/Rx Loss Port3 0: NO 1: YES
1.3.6.1.4.1.4756.20.501.20.1.125ColumnnidPort2LLFLogicPort4RemoteAread-writecurrentNID Series card Port2 link loss forwarding - Link/Rx Loss Port4 0: NO 1: YES
1.3.6.1.4.1.4756.20.501.20.1.126ColumnnidPort2LLFLogicPort5RemoteAread-writecurrentNID Series card Port2 link loss forwarding - Link/Rx Loss Port54 0: NO 1: YES
1.3.6.1.4.1.4756.20.501.20.1.127ColumnnidPort2LLFLogicPort6RemoteAread-writecurrentNID Series card Port2 link loss forwarding - Link/Rx Loss Port6 0: NO 1: YES
1.3.6.1.4.1.4756.20.501.20.1.128ColumnnidPort2LLFLogicPort7RemoteAread-writecurrentNID Series card Port2 link loss forwarding - Link/Rx Loss Port7 0: NO 1: YES
1.3.6.1.4.1.4756.20.501.20.1.129ColumnnidPort2LLFLogicPort8RemoteAread-writecurrentNID Series card Port2 link loss forwarding - Link/Rx Loss Port8 0: NO 1: YES
1.3.6.1.4.1.4756.20.501.20.1.130ColumnnidPort3LLFLogicRemoteAread-writecurrentNID Series card Port1 link loss forwarding - Logic 0: AND 1: OR
1.3.6.1.4.1.4756.20.501.20.1.131ColumnnidPort3LLFLogicPort1RemoteAread-writecurrentNID Series card Port3 link loss forwarding - Link/Rx Loss Port1 0: NO 1: YES
1.3.6.1.4.1.4756.20.501.20.1.132ColumnnidPort3LLFLogicPort2RemoteAread-writecurrentNID Series card Port3 link loss forwarding - Link/Rx Loss Port2 0: NO 1: YES
1.3.6.1.4.1.4756.20.501.20.1.133ColumnnidPort3LLFLogicPort4RemoteAread-writecurrentNID Series card Port3 link loss forwarding - Link/Rx Loss Port4 0: NO 1: YES
1.3.6.1.4.1.4756.20.501.20.1.134ColumnnidPort3LLFLogicPort5RemoteAread-writecurrentNID Series card Port3 link loss forwarding - Link/Rx Loss Port5 0: NO 1: YES
1.3.6.1.4.1.4756.20.501.20.1.135ColumnnidPort3LLFLogicPort6RemoteAread-writecurrentNID Series card Port3 link loss forwarding - Link/Rx Loss Port6 0: NO 1: YES
1.3.6.1.4.1.4756.20.501.20.1.136ColumnnidPort3LLFLogicPort7RemoteAread-writecurrentNID Series card Port3 link loss forwarding - Link/Rx Loss Port7 0: NO 1: YES
1.3.6.1.4.1.4756.20.501.20.1.137ColumnnidPort3LLFLogicPort8RemoteAread-writecurrentNID Series card Port3 link loss forwarding - Link/Rx Loss Port8 0: NO 1: YES
1.3.6.1.4.1.4756.20.501.20.1.138ColumnnidPort4LLFLogicRemoteAread-writecurrentNID Series card Port4 link loss forwarding - Logic 0: AND 1: OR
1.3.6.1.4.1.4756.20.501.20.1.139ColumnnidPort4LLFLogicPort1RemoteAread-writecurrentNID Series card Port4 link loss forwarding - Link/Rx Loss Port1 0: NO 1: YES
1.3.6.1.4.1.4756.20.501.20.1.140ColumnnidPort4LLFLogicPort2RemoteAread-writecurrentNID Series card Port4 link loss forwarding - Link/Rx Loss Port2 0: NO 1: YES
1.3.6.1.4.1.4756.20.501.20.1.141ColumnnidPort4LLFLogicPort3RemoteAread-writecurrentNID Series card Port4 link loss forwarding - Link/Rx Loss Port3 0: NO 1: YES
1.3.6.1.4.1.4756.20.501.20.1.142ColumnnidPort4LLFLogicPort5RemoteAread-writecurrentNID Series card Port4 link loss forwarding - Link/Rx Loss Port5 0: NO 1: YES
1.3.6.1.4.1.4756.20.501.20.1.143ColumnnidPort4LLFLogicPort6RemoteAread-writecurrentNID Series card Port4 link loss forwarding - Link/Rx Loss Port6 0: NO 1: YES
1.3.6.1.4.1.4756.20.501.20.1.144ColumnnidPort4LLFLogicPort7RemoteAread-writecurrentNID Series card Port4 link loss forwarding - Link/Rx Loss Port7 0: NO 1: YES
1.3.6.1.4.1.4756.20.501.20.1.145ColumnnidPort4LLFLogicPort8RemoteAread-writecurrentNID Series card Port4 link loss forwarding - Link/Rx Loss Port8 0: NO 1: YES
1.3.6.1.4.1.4756.20.501.20.1.146ColumnnidPort5LLFLogicRemoteAread-writecurrentNID Series card Port5 link loss forwarding - Logic 0: AND 1: OR
1.3.6.1.4.1.4756.20.501.20.1.147ColumnnidPort5LLFLogicPort1RemoteAread-writecurrentNID Series card Port5 link loss forwarding - Link/Rx Loss Port1 0: NO 1: YES
1.3.6.1.4.1.4756.20.501.20.1.148ColumnnidPort5LLFLogicPort2RemoteAread-writecurrentNID Series card Port5 link loss forwarding - Link/Rx Loss Port2 0: NO 1: YES
1.3.6.1.4.1.4756.20.501.20.1.149ColumnnidPort5LLFLogicPort3RemoteAread-writecurrentNID Series card Port5 link loss forwarding - Link/Rx Loss Port3 0: NO 1: YES
1.3.6.1.4.1.4756.20.501.20.1.150ColumnnidPort5LLFLogicPort4RemoteAread-writecurrentNID Series card Port5 link loss forwarding - Link/Rx Loss Port4 0: NO 1: YES
1.3.6.1.4.1.4756.20.501.20.1.151ColumnnidPort5LLFLogicPort6RemoteAread-writecurrentNID Series card Port5 link loss forwarding - Link/Rx Loss Port6 0: NO 1: YES
1.3.6.1.4.1.4756.20.501.20.1.152ColumnnidPort5LLFLogicPort7RemoteAread-writecurrentNID Series card Port5 link loss forwarding - Link/Rx Loss Port7 0: NO 1: YES
1.3.6.1.4.1.4756.20.501.20.1.153ColumnnidPort5LLFLogicPort8RemoteAread-writecurrentNID Series card Port5 link loss forwarding - Link/Rx Loss Port8 0: NO 1: YES
1.3.6.1.4.1.4756.20.501.20.1.154ColumnnidPort6LLFLogicRemoteAread-writecurrentNID Series card Port6 link loss forwarding - Logic 0: AND 1: OR
1.3.6.1.4.1.4756.20.501.20.1.155ColumnnidPort6LLFLogicPort1RemoteAread-writecurrentNID Series card Port6 link loss forwarding - Link/Rx Loss Port1 0: NO 1: YES
1.3.6.1.4.1.4756.20.501.20.1.156ColumnnidPort6LLFLogicPort2RemoteAread-writecurrentNID Series card Port6 link loss forwarding - Link/Rx Loss Port2 0: NO 1: YES
1.3.6.1.4.1.4756.20.501.20.1.157ColumnnidPort6LLFLogicPort3RemoteAread-writecurrentNID Series card Port6 link loss forwarding - Link/Rx Loss Port3 0: NO 1: YES
1.3.6.1.4.1.4756.20.501.20.1.158ColumnnidPort6LLFLogicPort4RemoteAread-writecurrentNID Series card Port6 link loss forwarding - Link/Rx Loss Port4 0: NO 1: YES
1.3.6.1.4.1.4756.20.501.20.1.159ColumnnidPort6LLFLogicPort5RemoteAread-writecurrentNID Series card Port6 link loss forwarding - Link/Rx Loss Port5 0: NO 1: YES
1.3.6.1.4.1.4756.20.501.20.1.160ColumnnidPort6LLFLogicPort7RemoteAread-writecurrentNID Series card Port4 link loss forwarding - Link/Rx Loss Port7 0: NO 1: YES
1.3.6.1.4.1.4756.20.501.20.1.161ColumnnidPort6LLFLogicPort8RemoteAread-writecurrentNID Series card Port6 link loss forwarding - Link/Rx Loss Port8 0: NO 1: YES
1.3.6.1.4.1.4756.20.501.20.1.162ColumnnidPort7LLFLogicRemoteAread-writecurrentNID Series card Port7 link loss forwarding - Logic 0: AND 1: OR
1.3.6.1.4.1.4756.20.501.20.1.163ColumnnidPort7LLFLogicPort1RemoteAread-writecurrentNID Series card Port7 link loss forwarding - Link/Rx Loss Port1 0: NO 1: YES
1.3.6.1.4.1.4756.20.501.20.1.164ColumnnidPort7LLFLogicPort2RemoteAread-writecurrentNID Series card Port7 link loss forwarding - Link/Rx Loss Port2 0: NO 1: YES
1.3.6.1.4.1.4756.20.501.20.1.165ColumnnidPort7LLFLogicPort3RemoteAread-writecurrentNID Series card Port7 link loss forwarding - Link/Rx Loss Port3 0: NO 1: YES
1.3.6.1.4.1.4756.20.501.20.1.166ColumnnidPort7LLFLogicPort4RemoteAread-writecurrentNID Series card Port7 link loss forwarding - Link/Rx Loss Port4 0: NO 1: YES
1.3.6.1.4.1.4756.20.501.20.1.167ColumnnidPort7LLFLogicPort5RemoteAread-writecurrentNID Series card Port7 link loss forwarding - Link/Rx Loss Port5 0: NO 1: YES
1.3.6.1.4.1.4756.20.501.20.1.168ColumnnidPort7LLFLogicPort6RemoteAread-writecurrentNID Series card Port4 link loss forwarding - Link/Rx Loss Port6 0: NO 1: YES
1.3.6.1.4.1.4756.20.501.20.1.169ColumnnidPort7LLFLogicPort8RemoteAread-writecurrentNID Series card Port7 link loss forwarding - Link/Rx Loss Port8 0: NO 1: YES
1.3.6.1.4.1.4756.20.501.20.1.170ColumnnidPort8LLFLogicRemoteAread-writecurrentNID Series card Port8 link loss forwarding - Logic 0: AND 1: OR
1.3.6.1.4.1.4756.20.501.20.1.171ColumnnidPort8LLFLogicPort1RemoteAread-writecurrentNID Series card Port8 link loss forwarding - Link/Rx Loss Port1 0: NO 1: YES
1.3.6.1.4.1.4756.20.501.20.1.172ColumnnidPort8LLFLogicPort2RemoteAread-writecurrentNID Series card Port8 link loss forwarding - Link/Rx Loss Port2 0: NO 1: YES
1.3.6.1.4.1.4756.20.501.20.1.173ColumnnidPort8LLFLogicPort3RemoteAread-writecurrentNID Series card Port5 link loss forwarding - Link/Rx Loss Port3 0: NO 1: YES
1.3.6.1.4.1.4756.20.501.20.1.174ColumnnidPort8LLFLogicPort4RemoteAread-writecurrentNID Series card Port8 link loss forwarding - Link/Rx Loss Port4 0: NO 1: YES
1.3.6.1.4.1.4756.20.501.20.1.175ColumnnidPort8LLFLogicPort5RemoteAread-writecurrentNID Series card Port8 link loss forwarding - Link/Rx Loss Port5 0: NO 1: YES
1.3.6.1.4.1.4756.20.501.20.1.176ColumnnidPort8LLFLogicPort6RemoteAread-writecurrentNID Series card Port8 link loss forwarding - Link/Rx Loss Port6 0: NO 1: YES
1.3.6.1.4.1.4756.20.501.20.1.177ColumnnidPort8LLFLogicPort7RemoteAread-writecurrentNID Series card Port8 link loss forwarding - Link/Rx Loss Port7 0: NO 1: YES
1.3.6.1.4.1.4756.20.501.20.1.178ColumnnidPort1PacketsRxRemoteAread-onlycurrentNID Series card port1 traffic overview:: Packets Rx
1.3.6.1.4.1.4756.20.501.20.1.179ColumnnidPort1PacketsTxRemoteAread-onlycurrentNID Series card port1 traffic overview:: Packets Tx
1.3.6.1.4.1.4756.20.501.20.1.180ColumnnidPort1BytesRxRemoteAread-onlycurrentNID Series card port1 traffic overview:: Bytes Rx
1.3.6.1.4.1.4756.20.501.20.1.181ColumnnidPort1BytesTxRemoteAread-onlycurrentNID Series card port1 traffic overview:: Bytes Tx
1.3.6.1.4.1.4756.20.501.20.1.182ColumnnidPort1ErrorsRxRemoteAread-onlycurrentNID Series card port1 traffic overview:: Errors Rx
1.3.6.1.4.1.4756.20.501.20.1.183ColumnnidPort1ErrorsTxRemoteAread-onlycurrentNID Series card port1 traffic overview:: Errors Tx
1.3.6.1.4.1.4756.20.501.20.1.184ColumnnidPort1DropsRxRemoteAread-onlycurrentNID Series card port1 traffic overview:: Drops Rx
1.3.6.1.4.1.4756.20.501.20.1.185ColumnnidPort1DropsTxRemoteAread-onlycurrentNID Series card port1 traffic overview:: Drops Tx
1.3.6.1.4.1.4756.20.501.20.1.186ColumnnidPort1FilteredRxRemoteAread-onlycurrentNID Series card port1 traffic overview:: Filtered Rx
1.3.6.1.4.1.4756.20.501.20.1.187ColumnnidPort2PacketsRxRemoteAread-onlycurrentNID Series card port2 traffic overview:: Packets Rx
1.3.6.1.4.1.4756.20.501.20.1.188ColumnnidPort2PacketsTxRemoteAread-onlycurrentNID Series card port2 traffic overview:: Packets Tx
1.3.6.1.4.1.4756.20.501.20.1.189ColumnnidPort2BytesRxRemoteAread-onlycurrentNID Series card port2 traffic overview:: Bytes Rx
1.3.6.1.4.1.4756.20.501.20.1.190ColumnnidPort2BytesTxRemoteAread-onlycurrentNID Series card port2 traffic overview:: Bytes Tx
1.3.6.1.4.1.4756.20.501.20.1.191ColumnnidPort2ErrorsRxRemoteAread-onlycurrentNID Series card port2 traffic overview:: Errors Rx
1.3.6.1.4.1.4756.20.501.20.1.192ColumnnidPort2ErrorsTxRemoteAread-onlycurrentNID Series card port2 traffic overview:: Errors Tx
1.3.6.1.4.1.4756.20.501.20.1.193ColumnnidPort2DropsRxRemoteAread-onlycurrentNID Series card port2 traffic overview:: Drops Rx
1.3.6.1.4.1.4756.20.501.20.1.194ColumnnidPort2DropsTxRemoteAread-onlycurrentNID Series card port2 traffic overview:: Drops Tx
1.3.6.1.4.1.4756.20.501.20.1.195ColumnnidPort2FilteredRxRemoteAread-onlycurrentNID Series card port2 traffic overview:: Filtered Rx
1.3.6.1.4.1.4756.20.501.20.1.196ColumnnidPort3PacketsRxRemoteAread-onlycurrentNID Series card port3 traffic overview:: Packets Rx
1.3.6.1.4.1.4756.20.501.20.1.197ColumnnidPort3PacketsTxRemoteAread-onlycurrentNID Series card port3 traffic overview:: Packets Tx
1.3.6.1.4.1.4756.20.501.20.1.198ColumnnidPort3BytesRxRemoteAread-onlycurrentNID Series card port3 traffic overview:: Bytes Rx
1.3.6.1.4.1.4756.20.501.20.1.199ColumnnidPort3BytesTxRemoteAread-onlycurrentNID Series card port3 traffic overview:: Bytes Tx
1.3.6.1.4.1.4756.20.501.20.1.200ColumnnidPort3ErrorsRxRemoteAread-onlycurrentNID Series card port3 traffic overview:: Errors Rx
1.3.6.1.4.1.4756.20.501.20.1.201ColumnnidPort3ErrorsTxRemoteAread-onlycurrentNID Series card port3 traffic overview:: Errors Tx
1.3.6.1.4.1.4756.20.501.20.1.202ColumnnidPort3DropsRxRemoteAread-onlycurrentNID Series card port3 traffic overview:: Drops Rx
1.3.6.1.4.1.4756.20.501.20.1.203ColumnnidPort3DropsTxRemoteAread-onlycurrentNID Series card port3 traffic overview:: Drops Tx
1.3.6.1.4.1.4756.20.501.20.1.204ColumnnidPort3FilteredRxRemoteAread-onlycurrentNID Series card port3 traffic overview:: Filtered Rx
1.3.6.1.4.1.4756.20.501.20.1.205ColumnnidPort4PacketsRxRemoteAread-onlycurrentNID Series card port4 traffic overview:: Packets Rx
1.3.6.1.4.1.4756.20.501.20.1.206ColumnnidPort4PacketsTxRemoteAread-onlycurrentNID Series card port4 traffic overview:: Packets Tx
1.3.6.1.4.1.4756.20.501.20.1.207ColumnnidPort4BytesRxRemoteAread-onlycurrentNID Series card port4 traffic overview:: Bytes Rx
1.3.6.1.4.1.4756.20.501.20.1.208ColumnnidPort4BytesTxRemoteAread-onlycurrentNID Series card port4 traffic overview:: Bytes Tx
1.3.6.1.4.1.4756.20.501.20.1.209ColumnnidPort4ErrorsRxRemoteAread-onlycurrentNID Series card port4 traffic overview:: Errors Rx
1.3.6.1.4.1.4756.20.501.20.1.210ColumnnidPort4ErrorsTxRemoteAread-onlycurrentNID Series card port4 traffic overview:: Errors Tx
1.3.6.1.4.1.4756.20.501.20.1.211ColumnnidPort4DropsRxRemoteAread-onlycurrentNID Series card port4 traffic overview:: Drops Rx
1.3.6.1.4.1.4756.20.501.20.1.212ColumnnidPort4DropsTxRemoteAread-onlycurrentNID Series card port4 traffic overview:: Drops Tx
1.3.6.1.4.1.4756.20.501.20.1.213ColumnnidPort4FilteredRxRemoteAread-onlycurrentNID Series card port4 traffic overview:: Filtered Rx
1.3.6.1.4.1.4756.20.501.20.1.214ColumnnidPort5PacketsRxRemoteAread-onlycurrentNID Series card port5 traffic overview:: Packets Rx
1.3.6.1.4.1.4756.20.501.20.1.215ColumnnidPort5PacketsTxRemoteAread-onlycurrentNID Series card port5 traffic overview:: Packets Tx
1.3.6.1.4.1.4756.20.501.20.1.216ColumnnidPort5BytesRxRemoteAread-onlycurrentNID Series card port5 traffic overview:: Bytes Rx
1.3.6.1.4.1.4756.20.501.20.1.217ColumnnidPort5BytesTxRemoteAread-onlycurrentNID Series card port5 traffic overview:: Bytes Tx
1.3.6.1.4.1.4756.20.501.20.1.218ColumnnidPort5ErrorsRxRemoteAread-onlycurrentNID Series card port5 traffic overview:: Errors Rx
1.3.6.1.4.1.4756.20.501.20.1.219ColumnnidPort5ErrorsTxRemoteAread-onlycurrentNID Series card port5 traffic overview:: Errors Tx
1.3.6.1.4.1.4756.20.501.20.1.220ColumnnidPort5DropsRxRemoteAread-onlycurrentNID Series card port5 traffic overview:: Drops Rx
1.3.6.1.4.1.4756.20.501.20.1.221ColumnnidPort5DropsTxRemoteAread-onlycurrentNID Series card port5 traffic overview:: Drops Tx
1.3.6.1.4.1.4756.20.501.20.1.222ColumnnidPort5FilteredRxRemoteAread-onlycurrentNID Series card port5 traffic overview:: Filtered Rx
1.3.6.1.4.1.4756.20.501.20.1.223ColumnnidPort6PacketsRxRemoteAread-onlycurrentNID Series card port6 traffic overview:: Packets Rx
1.3.6.1.4.1.4756.20.501.20.1.224ColumnnidPort6PacketsTxRemoteAread-onlycurrentNID Series card port6 traffic overview:: Packets Tx
1.3.6.1.4.1.4756.20.501.20.1.225ColumnnidPort6BytesRxRemoteAread-onlycurrentNID Series card port6 traffic overview:: Bytes Rx
1.3.6.1.4.1.4756.20.501.20.1.226ColumnnidPort6BytesTxRemoteAread-onlycurrentNID Series card port6 traffic overview:: Bytes Tx
1.3.6.1.4.1.4756.20.501.20.1.227ColumnnidPort6ErrorsRxRemoteAread-onlycurrentNID Series card port6 traffic overview:: Errors Rx
1.3.6.1.4.1.4756.20.501.20.1.228ColumnnidPort6ErrorsTxRemoteAread-onlycurrentNID Series card port6 traffic overview:: Errors Tx
1.3.6.1.4.1.4756.20.501.20.1.229ColumnnidPort6DropsRxRemoteAread-onlycurrentNID Series card port6 traffic overview:: Drops Rx
1.3.6.1.4.1.4756.20.501.20.1.230ColumnnidPort6DropsTxRemoteAread-onlycurrentNID Series card port6 traffic overview:: Drops Tx
1.3.6.1.4.1.4756.20.501.20.1.231ColumnnidPort6FilteredRxRemoteAread-onlycurrentNID Series card port6 traffic overview:: Filtered Rx
1.3.6.1.4.1.4756.20.501.20.1.232ColumnnidPort7PacketsRxRemoteAread-onlycurrentNID Series card port7 traffic overview:: Packets Rx
1.3.6.1.4.1.4756.20.501.20.1.233ColumnnidPort7PacketsTxRemoteAread-onlycurrentNID Series card port7 traffic overview:: Packets Tx
1.3.6.1.4.1.4756.20.501.20.1.234ColumnnidPort7BytesRxRemoteAread-onlycurrentNID Series card port7 traffic overview:: Bytes Rx
1.3.6.1.4.1.4756.20.501.20.1.235ColumnnidPort7BytesTxRemoteAread-onlycurrentNID Series card port7 traffic overview:: Bytes Tx
1.3.6.1.4.1.4756.20.501.20.1.236ColumnnidPort7ErrorsRxRemoteAread-onlycurrentNID Series card port7 traffic overview:: Errors Rx
1.3.6.1.4.1.4756.20.501.20.1.237ColumnnidPort7ErrorsTxRemoteAread-onlycurrentNID Series card port7 traffic overview:: Errors Tx
1.3.6.1.4.1.4756.20.501.20.1.238ColumnnidPort7DropsRxRemoteAread-onlycurrentNID Series card port7 traffic overview:: Drops Rx
1.3.6.1.4.1.4756.20.501.20.1.239ColumnnidPort7DropsTxRemoteAread-onlycurrentNID Series card port7 traffic overview:: Drops Tx
1.3.6.1.4.1.4756.20.501.20.1.240ColumnnidPort7FilteredRxRemoteAread-onlycurrentNID Series card port7 traffic overview:: Filtered Rx
1.3.6.1.4.1.4756.20.501.20.1.241ColumnnidPort8PacketsRxRemoteAread-onlycurrentNID Series card port8 traffic overview:: Packets Rx
1.3.6.1.4.1.4756.20.501.20.1.242ColumnnidPort8PacketsTxRemoteAread-onlycurrentNID Series card port8 traffic overview:: Packets Tx
1.3.6.1.4.1.4756.20.501.20.1.243ColumnnidPort8BytesRxRemoteAread-onlycurrentNID Series card port8 traffic overview:: Bytes Rx
1.3.6.1.4.1.4756.20.501.20.1.244ColumnnidPort8BytesTxRemoteAread-onlycurrentNID Series card port8 traffic overview:: Bytes Tx
1.3.6.1.4.1.4756.20.501.20.1.245ColumnnidPort8ErrorsRxRemoteAread-onlycurrentNID Series card port8 traffic overview:: Errors Rx
1.3.6.1.4.1.4756.20.501.20.1.246ColumnnidPort8ErrorsTxRemoteAread-onlycurrentNID Series card port8 traffic overview:: Errors Tx
1.3.6.1.4.1.4756.20.501.20.1.247ColumnnidPort8DropsRxRemoteAread-onlycurrentNID Series card port8 traffic overview:: Drops Rx
1.3.6.1.4.1.4756.20.501.20.1.248ColumnnidPort8DropsTxRemoteAread-onlycurrentNID Series card port8 traffic overview:: Drops Tx
1.3.6.1.4.1.4756.20.501.20.1.249ColumnnidPort8FilteredRxRemoteAread-onlycurrentNID Series card port8 traffic overview:: Filtered Rx
1.3.6.1.4.1.4756.20.501.20.1.250ColumnnidAggrSourceMACAddrRemoteAread-writecurrentNID Series card Aggregation Mode Configuration: Source MAC Address 0: No 1: Yes
1.3.6.1.4.1.4756.20.501.20.1.251ColumnnidAggrDestinationMACAddrRemoteAread-writecurrentNID Series card Aggregation Mode Configuration: Destination MAC Address 0: No 1: Yes
1.3.6.1.4.1.4756.20.501.20.1.252ColumnnidAggrIPAddrRemoteAread-writecurrentNID Series card Aggregation Mode Configuration: IP Address 0: No 1: Yes
1.3.6.1.4.1.4756.20.501.20.1.253ColumnnidAggrTCPUDPPortNumRemoteAread-writecurrentNID Series card Aggregation Mode Configuration: TCP/UDP Port Number 0: No 1: Yes
1.3.6.1.4.1.4756.20.501.20.1.254ColumnnidAggrGroupPort1ConfRemoteAread-writecurrentNID Series card Aggregation Group Port1 Configuration: 0: Normal 1: ID1 2: ID2 3: ID3 4: ID4
1.3.6.1.4.1.4756.20.501.20.1.255ColumnnidAggrGroupPort2ConfRemoteAread-writecurrentNID Series card Aggregation Group Port2 Configuration: 0: Normal 1: ID1 2: ID2 3: ID3 4: ID4
1.3.6.1.4.1.4756.20.501.20.1.256ColumnnidAggrGroupPort3ConfRemoteAread-writecurrentNID Series card Aggregation Group Port3 Configuration: 0: Normal 1: ID1 2: ID2 3: ID3 4: ID4
1.3.6.1.4.1.4756.20.501.20.1.257ColumnnidAggrGroupPort4ConfRemoteAread-writecurrentNID Series card Aggregation Group Port4 Configuration: 0: Normal 1: ID1 2: ID2 3: ID3 4: ID4
1.3.6.1.4.1.4756.20.501.20.1.258ColumnnidAggrGroupPort5ConfRemoteAread-writecurrentNID Series card Aggregation Group Port5 Configuration: 0: Normal 1: ID1 2: ID2 3: ID3 4: ID4
1.3.6.1.4.1.4756.20.501.20.1.259ColumnnidAggrGroupPort6ConfRemoteAread-writecurrentNID Series card Aggregation Group Port6 Configuration: 0: Normal 1: ID1 2: ID2 3: ID3 4: ID4
1.3.6.1.4.1.4756.20.501.20.1.260ColumnnidAggrGroupPort7ConfRemoteAread-writecurrentNID Series card Aggregation Group Port7 Configuration: 0: Normal 1: ID1 2: ID2 3: ID3 4: ID4
1.3.6.1.4.1.4756.20.501.20.1.261ColumnnidAggrGroupPort8ConfRemoteAread-writecurrentNID Series card Aggregation Group Port8 Configuration: 0: Normal 1: ID1 2: ID2 3: ID3 4: ID4
1.3.6.1.4.1.4756.20.501.20.1.262ColumnnidPort1LACPEnabledRemoteAread-writecurrentNID Series card Port1 LACP Enabled: 0: No 1: Yes
1.3.6.1.4.1.4756.20.501.20.1.263ColumnnidPort1LACPKEYRemoteAread-writecurrentNID Series card Port1 LACP Key value: The Key value incurred by the port, range 0-65535.The value of 0 means auto.
1.3.6.1.4.1.4756.20.501.20.1.264ColumnnidPort1LACPRoleRemoteAread-writecurrentNID Series card Port1 LACP Role: 0: Passive 1: Active
1.3.6.1.4.1.4756.20.501.20.1.265ColumnnidPort1LACPTimeOutRemoteAread-writecurrentNID Series card Port1 LACP Time out: 0: Slow 1: Fast
1.3.6.1.4.1.4756.20.501.20.1.266ColumnnidPort1LACPPrioRemoteAread-writecurrentNID Series card Port1 LACP priority: The Key value incurred by the port, range 1-65535.
1.3.6.1.4.1.4756.20.501.20.1.267ColumnnidPort2LACPEnabledRemoteAread-writecurrentNID Series card Port2 LACP Enabled: 0: No 1: Yes
1.3.6.1.4.1.4756.20.501.20.1.268ColumnnidPort2LACPKEYRemoteAread-writecurrentNID Series card Port2 LACP Key value: The Key value incurred by the port, range 0-65535.The value of 0 means auto.
1.3.6.1.4.1.4756.20.501.20.1.269ColumnnidPort2LACPRoleRemoteAread-writecurrentNID Series card Port2 LACP Role: 0: Passive 1: Active
1.3.6.1.4.1.4756.20.501.20.1.270ColumnnidPort2LACPTimeOutRemoteAread-writecurrentNID Series card Port2 LACP Time out: 0: Slow 1: Fast
1.3.6.1.4.1.4756.20.501.20.1.271ColumnnidPort2LACPPrioRemoteAread-writecurrentNID Series card Port2 LACP priority: The Key value incurred by the port, range 1-65535.
1.3.6.1.4.1.4756.20.501.20.1.272ColumnnidPort3LACPEnabledRemoteAread-writecurrentNID Series card Port3 LACP Enabled: 0: No 1: Yes
1.3.6.1.4.1.4756.20.501.20.1.273ColumnnidPort3LACPKEYRemoteAread-writecurrentNID Series card Port3 LACP Key value: The Key value incurred by the port, range 0-65535.The value of 0 means auto.
1.3.6.1.4.1.4756.20.501.20.1.274ColumnnidPort3LACPRoleRemoteAread-writecurrentNID Series card Port3 LACP Role: 0: Passive 1: Active
1.3.6.1.4.1.4756.20.501.20.1.275ColumnnidPort3LACPTimeOutRemoteAread-writecurrentNID Series card Port3 LACP Time out: 0: Slow 1: Fast
1.3.6.1.4.1.4756.20.501.20.1.276ColumnnidPort3LACPPrioRemoteAread-writecurrentNID Series card Port3 LACP priority: The Key value incurred by the port, range 1-65535.
1.3.6.1.4.1.4756.20.501.20.1.277ColumnnidPort4LACPEnabledRemoteAread-writecurrentNID Series card Port4 LACP Enabled: 0: No 1: Yes
1.3.6.1.4.1.4756.20.501.20.1.278ColumnnidPort4LACPKEYRemoteAread-writecurrentNID Series card Port4 LACP Key value: The Key value incurred by the port, range 0-65535.The value of 0 means auto.
1.3.6.1.4.1.4756.20.501.20.1.279ColumnnidPort4LACPRoleRemoteAread-writecurrentNID Series card Port4 LACP Role: 0: Passive 1: Active
1.3.6.1.4.1.4756.20.501.20.1.280ColumnnidPort4LACPTimeOutRemoteAread-writecurrentNID Series card Port4 LACP Time out: 0: Slow 1: Fast
1.3.6.1.4.1.4756.20.501.20.1.281ColumnnidPort4LACPPrioRemoteAread-writecurrentNID Series card Port4 LACP priority: The Key value incurred by the port, range 1-65535.
1.3.6.1.4.1.4756.20.501.20.1.282ColumnnidPort5LACPEnabledRemoteAread-writecurrentNID Series card Port5 LACP Enabled: 0: No 1: Yes
1.3.6.1.4.1.4756.20.501.20.1.283ColumnnidPort5LACPKEYRemoteAread-writecurrentNID Series card Port5 LACP Key value: The Key value incurred by the port, range 0-65535.The value of 0 means auto.
1.3.6.1.4.1.4756.20.501.20.1.284ColumnnidPort5LACPRoleRemoteAread-writecurrentNID Series card Port5 LACP Role: 0: Passive 1: Active
1.3.6.1.4.1.4756.20.501.20.1.285ColumnnidPort5LACPTimeOutRemoteAread-writecurrentNID Series card Port5 LACP Time out: 0: Slow 1: Fast
1.3.6.1.4.1.4756.20.501.20.1.286ColumnnidPort5LACPPrioRemoteAread-writecurrentNID Series card Port5 LACP priority: The Key value incurred by the port, range 1-65535.
1.3.6.1.4.1.4756.20.501.20.1.287ColumnnidPort6LACPEnabledRemoteAread-writecurrentNID Series card Port6 LACP Enabled: 0: No 1: Yes
1.3.6.1.4.1.4756.20.501.20.1.288ColumnnidPort6LACPKEYRemoteAread-writecurrentNID Series card Port6 LACP Key value: The Key value incurred by the port, range 0-65535.The value of 0 means auto.
1.3.6.1.4.1.4756.20.501.20.1.289ColumnnidPort6LACPRoleRemoteAread-writecurrentNID Series card Port6 LACP Role: 0: Passive 1: Active
1.3.6.1.4.1.4756.20.501.20.1.290ColumnnidPort6LACPTimeOutRemoteAread-writecurrentNID Series card Port6 LACP Time out: 0: Slow 1: Fast
1.3.6.1.4.1.4756.20.501.20.1.291ColumnnidPort6LACPPrioRemoteAread-writecurrentNID Series card Port6 LACP priority: The Key value incurred by the port, range 1-65535.
1.3.6.1.4.1.4756.20.501.20.1.292ColumnnidPort7LACPEnabledRemoteAread-writecurrentNID Series card Port7 LACP Enabled: 0: No 1: Yes
1.3.6.1.4.1.4756.20.501.20.1.293ColumnnidPort7LACPKEYRemoteAread-writecurrentNID Series card Port7 LACP Key value: The Key value incurred by the port, range 0-65535.The value of 0 means auto.
1.3.6.1.4.1.4756.20.501.20.1.294ColumnnidPort7LACPRoleRemoteAread-writecurrentNID Series card Port7 LACP Role: 0: Passive 1: Active
1.3.6.1.4.1.4756.20.501.20.1.295ColumnnidPort7LACPTimeOutRemoteAread-writecurrentNID Series card Port7 LACP Time out: 0: Slow 1: Fast
1.3.6.1.4.1.4756.20.501.20.1.296ColumnnidPort7LACPPrioRemoteAread-writecurrentNID Series card Port7 LACP priority: The Key value incurred by the port, range 1-65535.
1.3.6.1.4.1.4756.20.501.20.1.297ColumnnidPort8LACPEnabledRemoteAread-writecurrentNID Series card Port8 LACP Enabled: 0: No 1: Yes
1.3.6.1.4.1.4756.20.501.20.1.298ColumnnidPort8LACPKEYRemoteAread-writecurrentNID Series card Port8 LACP Key value: The Key value incurred by the port, range 0-65535.The value of 0 means auto.
1.3.6.1.4.1.4756.20.501.20.1.299ColumnnidPort8LACPRoleRemoteAread-writecurrentNID Series card Port8 LACP Role: 0: Passive 1: Active
1.3.6.1.4.1.4756.20.501.20.1.300ColumnnidPort8LACPTimeOutRemoteAread-writecurrentNID Series card Port8 LACP Time out: 0: Slow 1: Fast
1.3.6.1.4.1.4756.20.501.20.1.301ColumnnidPort8LACPPrioRemoteAread-writecurrentNID Series card Port8 LACP priority: The Key value incurred by the port, range 1-65535.
1.3.6.1.4.1.4756.20.501.20.1.302ColumnnidPort1LACPstsRemoteAread-onlycurrentNID Series card Port1 LACP status: 0: No 1: Yes 2: Standby
1.3.6.1.4.1.4756.20.501.20.1.303ColumnnidPort1LACPKEYstsRemoteAread-onlycurrentNID Series card Port1 LACP status: Key
1.3.6.1.4.1.4756.20.501.20.1.304ColumnnidPort1LACPAggrIDstsRemoteAread-onlycurrentNID Series card Port1 LACP status: Aggr ID
1.3.6.1.4.1.4756.20.501.20.1.305ColumnnidPort1LACPParnterSysIDstsRemoteAread-onlycurrentNID Series card Port1 LACP status: Parnter System ID
1.3.6.1.4.1.4756.20.501.20.1.306ColumnnidPort1LACPParnterPortstsRemoteAread-onlycurrentNID Series card Port1 LACP status: Parnter Port Status
1.3.6.1.4.1.4756.20.501.20.1.307ColumnnidPort1LACPParnterProistsRemoteAread-onlycurrentNID Series card Port1 LACP status: Parnter Priority
1.3.6.1.4.1.4756.20.501.20.1.308ColumnnidPort2LACPstsRemoteAread-onlycurrentNID Series card Port2 LACP status: 0: No 1: Yes 2: Standby
1.3.6.1.4.1.4756.20.501.20.1.309ColumnnidPort2LACPKEYstsRemoteAread-onlycurrentNID Series card Port2 LACP status: Key
1.3.6.1.4.1.4756.20.501.20.1.310ColumnnidPort2LACPAggrIDstsRemoteAread-onlycurrentNID Series card Port2 LACP status: Aggr ID
1.3.6.1.4.1.4756.20.501.20.1.311ColumnnidPort2LACPParnterSysIDstsRemoteAread-onlycurrentNID Series card Port2 LACP status: Parnter System ID
1.3.6.1.4.1.4756.20.501.20.1.312ColumnnidPort2LACPParnterPortstsRemoteAread-onlycurrentNID Series card Port2 LACP status: Parnter Port Status
1.3.6.1.4.1.4756.20.501.20.1.313ColumnnidPort2LACPParnterProistsRemoteAread-onlycurrentNID Series card Port2 LACP status: Parnter Priority
1.3.6.1.4.1.4756.20.501.20.1.314ColumnnidPort3LACPstsRemoteAread-onlycurrentNID Series card Port3 LACP status: 0: No 1: Yes 2: Standby
1.3.6.1.4.1.4756.20.501.20.1.315ColumnnidPort3LACPKEYstsRemoteAread-onlycurrentNID Series card Port3 LACP status: Key
1.3.6.1.4.1.4756.20.501.20.1.316ColumnnidPort3LACPAggrIDstsRemoteAread-onlycurrentNID Series card Port3 LACP status: Aggr ID
1.3.6.1.4.1.4756.20.501.20.1.317ColumnnidPort3LACPParnterSysIDstsRemoteAread-onlycurrentNID Series card Port3 LACP status: Parnter System ID
1.3.6.1.4.1.4756.20.501.20.1.318ColumnnidPort3LACPParnterPortstsRemoteAread-onlycurrentNID Series card Port3 LACP status: Parnter Port Status
1.3.6.1.4.1.4756.20.501.20.1.319ColumnnidPort3LACPParnterProistsRemoteAread-onlycurrentNID Series card Port3 LACP status: Parnter Priority
1.3.6.1.4.1.4756.20.501.20.1.320ColumnnidPort4LACPstsRemoteAread-onlycurrentNID Series card Port4 LACP status: 0: No 1: Yes 2: Standby
1.3.6.1.4.1.4756.20.501.20.1.321ColumnnidPort4LACPKEYstsRemoteAread-onlycurrentNID Series card Port4 LACP status: Key
1.3.6.1.4.1.4756.20.501.20.1.322ColumnnidPort4LACPAggrIDstsRemoteAread-onlycurrentNID Series card Port4 LACP status: Aggr ID
1.3.6.1.4.1.4756.20.501.20.1.323ColumnnidPort4LACPParnterSysIDstsRemoteAread-onlycurrentNID Series card Port4 LACP status: Parnter System ID
1.3.6.1.4.1.4756.20.501.20.1.324ColumnnidPort4LACPParnterPortstsRemoteAread-onlycurrentNID Series card Port4 LACP status: Parnter Port Status
1.3.6.1.4.1.4756.20.501.20.1.325ColumnnidPort4LACPParnterProistsRemoteAread-onlycurrentNID Series card Port4 LACP status: Parnter Priority
1.3.6.1.4.1.4756.20.501.20.1.326ColumnnidPort5LACPstsRemoteAread-onlycurrentNID Series card Port5 LACP status: 0: No 1: Yes 2: Standby
1.3.6.1.4.1.4756.20.501.20.1.327ColumnnidPort5LACPKEYstsRemoteAread-onlycurrentNID Series card Port5 LACP status: Key
1.3.6.1.4.1.4756.20.501.20.1.328ColumnnidPort5LACPAggrIDstsRemoteAread-onlycurrentNID Series card Port5 LACP status: Aggr ID
1.3.6.1.4.1.4756.20.501.20.1.329ColumnnidPort5LACPParnterSysIDstsRemoteAread-onlycurrentNID Series card Port5 LACP status: Parnter System ID
1.3.6.1.4.1.4756.20.501.20.1.330ColumnnidPort5LACPParnterPortstsRemoteAread-onlycurrentNID Series card Port5 LACP status: Parnter Port Status
1.3.6.1.4.1.4756.20.501.20.1.331ColumnnidPort5LACPParnterProistsRemoteAread-onlycurrentNID Series card Port5 LACP status: Parnter Priority
1.3.6.1.4.1.4756.20.501.20.1.332ColumnnidPort6LACPstsRemoteAread-onlycurrentNID Series card Port6 LACP status: 0: No 1: Yes 2: Standby
1.3.6.1.4.1.4756.20.501.20.1.333ColumnnidPort6LACPKEYstsRemoteAread-onlycurrentNID Series card Port6 LACP status: Key
1.3.6.1.4.1.4756.20.501.20.1.334ColumnnidPort6LACPAggrIDstsRemoteAread-onlycurrentNID Series card Port6 LACP status: Aggr ID
1.3.6.1.4.1.4756.20.501.20.1.335ColumnnidPort6LACPParnterSysIDstsRemoteAread-onlycurrentNID Series card Port6 LACP status: Parnter System ID
1.3.6.1.4.1.4756.20.501.20.1.336ColumnnidPort6LACPParnterPortstsRemoteAread-onlycurrentNID Series card Port6 LACP status: Parnter Port Status
1.3.6.1.4.1.4756.20.501.20.1.337ColumnnidPort6LACPParnterProistsRemoteAread-onlycurrentNID Series card Port6 LACP status: Parnter Priority
1.3.6.1.4.1.4756.20.501.20.1.338ColumnnidPort7LACPstsRemoteAread-onlycurrentNID Series card Port7 LACP status: 0: No 1: Yes 2: Standby
1.3.6.1.4.1.4756.20.501.20.1.339ColumnnidPort7LACPKEYstsRemoteAread-onlycurrentNID Series card Port7 LACP status: Key
1.3.6.1.4.1.4756.20.501.20.1.340ColumnnidPort7LACPAggrIDstsRemoteAread-onlycurrentNID Series card Port7 LACP status: Aggr ID
1.3.6.1.4.1.4756.20.501.20.1.341ColumnnidPort7LACPParnterSysIDstsRemoteAread-onlycurrentNID Series card Port7 LACP status: Parnter System ID
1.3.6.1.4.1.4756.20.501.20.1.342ColumnnidPort7LACPParnterPortstsRemoteAread-onlycurrentNID Series card Port7 LACP status: Parnter Port Status
1.3.6.1.4.1.4756.20.501.20.1.343ColumnnidPort7LACPParnterProistsRemoteAread-onlycurrentNID Series card Port7 LACP status: Parnter Priority
1.3.6.1.4.1.4756.20.501.20.1.344ColumnnidPort8LACPstsRemoteAread-onlycurrentNID Series card Port8 LACP status: 0: No 1: Yes 2: Standby
1.3.6.1.4.1.4756.20.501.20.1.345ColumnnidPort8LACPKEYstsRemoteAread-onlycurrentNID Series card Port8 LACP status: Key
1.3.6.1.4.1.4756.20.501.20.1.346ColumnnidPort8LACPAggrIDstsRemoteAread-onlycurrentNID Series card Port8 LACP status: Aggr ID
1.3.6.1.4.1.4756.20.501.20.1.347ColumnnidPort8LACPParnterSysIDstsRemoteAread-onlycurrentNID Series card Port8 LACP status: Parnter System ID
1.3.6.1.4.1.4756.20.501.20.1.348ColumnnidPort8LACPParnterPortstsRemoteAread-onlycurrentNID Series card Port8 LACP status: Parnter Port Status
1.3.6.1.4.1.4756.20.501.20.1.349ColumnnidPort8LACPParnterProistsRemoteAread-onlycurrentNID Series card Port8 LACP status: Parnter Priority
1.3.6.1.4.1.4756.20.501.20.1.350ColumnnidOAMPort1EnableRemoteAread-writecurrentNID Series card Port1 OAM: 0: Off 1: On
1.3.6.1.4.1.4756.20.501.20.1.351ColumnnidOAMPort1ModeRemoteAread-writecurrentNID Series card Port1 OAM: 0: Passive 1: Active
1.3.6.1.4.1.4756.20.501.20.1.352ColumnnidOAMPort1LoopBackRemoteAread-writecurrentNID Series card Port1 OAM LoopBack: 0: Off 1: On
1.3.6.1.4.1.4756.20.501.20.1.353ColumnnidOAMPort1LinkMonitorRemoteAread-writecurrentNID Series card Port1 OAM Link Monitor: 0: Off 1: On
1.3.6.1.4.1.4756.20.501.20.1.354ColumnnidOAMPort1MIBRetrievalRemoteAread-writecurrentNID Series card Port1 OAM MIB Retrieval: 0: Off 1: On
1.3.6.1.4.1.4756.20.501.20.1.355ColumnnidOAMPort1LoopBackOPRemoteAread-writecurrentNID Series card Port1 OAM LoopBack operation: 0: Off 1: On
1.3.6.1.4.1.4756.20.501.20.1.356ColumnnidOAMPort2EnableRemoteAread-writecurrentNID Series card Port2 OAM: 0: Off 1: On
1.3.6.1.4.1.4756.20.501.20.1.357ColumnnidOAMPort2ModeRemoteAread-writecurrentNID Series card Port2 OAM: 0: Passive 1: Active
1.3.6.1.4.1.4756.20.501.20.1.358ColumnnidOAMPort2LoopBackRemoteAread-writecurrentNID Series card Port2 OAM LoopBack: 0: Off 1: On
1.3.6.1.4.1.4756.20.501.20.1.359ColumnnidOAMPort2LinkMonitorRemoteAread-writecurrentNID Series card Port2 OAM Link Monitor: 0: Off 1: On
1.3.6.1.4.1.4756.20.501.20.1.360ColumnnidOAMPort2MIBRetrievalRemoteAread-writecurrentNID Series card Port2 OAM MIB Retrieval: 0: Off 1: On
1.3.6.1.4.1.4756.20.501.20.1.361ColumnnidOAMPort2LoopBackOPRemoteAread-writecurrentNID Series card Port2 OAM LoopBack operation: 0: Off 1: On
1.3.6.1.4.1.4756.20.501.20.1.362ColumnnidOAMPort3EnableRemoteAread-writecurrentNID Series card Port3 OAM: 0: Off 1: On
1.3.6.1.4.1.4756.20.501.20.1.363ColumnnidOAMPort3ModeRemoteAread-writecurrentNID Series card Port3 OAM: 0: Passive 1: Active
1.3.6.1.4.1.4756.20.501.20.1.364ColumnnidOAMPort3LoopBackRemoteAread-writecurrentNID Series card Port3 OAM: 0: Off 1: On
1.3.6.1.4.1.4756.20.501.20.1.365ColumnnidOAMPort3LinkMonitorRemoteAread-writecurrentNID Series card Port3 OAM Link Monitor: 0: Off 1: On
1.3.6.1.4.1.4756.20.501.20.1.366ColumnnidOAMPort3MIBRetrievalRemoteAread-writecurrentNID Series card Port3 OAM MIB Retrieval: 0: Off 1: On
1.3.6.1.4.1.4756.20.501.20.1.367ColumnnidOAMPort3LoopBackOPRemoteAread-writecurrentNID Series card Port3 OAM LoopBack operation: 0: Disable 1: Enable
1.3.6.1.4.1.4756.20.501.20.1.368ColumnnidOAMPort4EnableRemoteAread-writecurrentNID Series card Port4 OAM: 0: Off 1: On
1.3.6.1.4.1.4756.20.501.20.1.369ColumnnidOAMPort4ModeRemoteAread-writecurrentNID Series card Port4 OAM: 0: Passive 1: Active
1.3.6.1.4.1.4756.20.501.20.1.370ColumnnidOAMPort4LoopBackRemoteAread-writecurrentNID Series card Port4 OAM: 0: Off 1: On
1.3.6.1.4.1.4756.20.501.20.1.371ColumnnidOAMPort4LinkMonitorRemoteAread-writecurrentNID Series card Port4 OAM Link Monitor: 0: Off 1: On
1.3.6.1.4.1.4756.20.501.20.1.372ColumnnidOAMPort4MIBRetrievalRemoteAread-writecurrentNID Series card Port4 OAM MIB Retrieval: 0: Off 1: On
1.3.6.1.4.1.4756.20.501.20.1.373ColumnnidOAMPort4LoopBackOPRemoteAread-writecurrentNID Series card Port4 OAM LoopBack operation: 0: On 1: Off
1.3.6.1.4.1.4756.20.501.20.1.374ColumnnidOAMPort5EnableRemoteAread-writecurrentNID Series card Port5 OAM: 0: Off 1: On
1.3.6.1.4.1.4756.20.501.20.1.375ColumnnidOAMPort5ModeRemoteAread-writecurrentNID Series card Port5 OAM: 0: Passive 1: Active
1.3.6.1.4.1.4756.20.501.20.1.376ColumnnidOAMPort5LoopBackRemoteAread-writecurrentNID Series card Port5 OAM: 0: Off 1: On
1.3.6.1.4.1.4756.20.501.20.1.377ColumnnidOAMPort5LinkMonitorRemoteAread-writecurrentNID Series card Port5 OAM Link Monitor: 0: Off 1: On
1.3.6.1.4.1.4756.20.501.20.1.378ColumnnidOAMPort5MIBRetrievalRemoteAread-writecurrentNID Series card Port5 OAM MIB Retrieval: 0: Off 1: On
1.3.6.1.4.1.4756.20.501.20.1.379ColumnnidOAMPort5LoopBackOPRemoteAread-writecurrentNID Series card Port5 OAM LoopBack operation: 0: On 1: Off
1.3.6.1.4.1.4756.20.501.20.1.380ColumnnidOAMPort6EnableRemoteAread-writecurrentNID Series card Port6 OAM: 0: Off 1: On
1.3.6.1.4.1.4756.20.501.20.1.381ColumnnidOAMPort6ModeRemoteAread-writecurrentNID Series card Port6 OAM: 0: Passive 1: Active
1.3.6.1.4.1.4756.20.501.20.1.382ColumnnidOAMPort6LoopBackRemoteAread-writecurrentNID Series card Port6 OAM: 0: Off 1: On
1.3.6.1.4.1.4756.20.501.20.1.383ColumnnidOAMPort6LinkMonitorRemoteAread-writecurrentNID Series card Port6 OAM Link Monitor: 0: Off 1: On
1.3.6.1.4.1.4756.20.501.20.1.384ColumnnidOAMPort6MIBRetrievalRemoteAread-writecurrentNID Series card Port6 OAM MIB Retrieval: 0: Off 1: On
1.3.6.1.4.1.4756.20.501.20.1.385ColumnnidOAMPort6LoopBackOPRemoteAread-writecurrentNID Series card Port6 OAM LoopBack operation: 0: On 1: Off
1.3.6.1.4.1.4756.20.501.20.1.386ColumnnidOAMPort7EnableRemoteAread-writecurrentNID Series card Port7 OAM: 0: Off 1: On
1.3.6.1.4.1.4756.20.501.20.1.387ColumnnidOAMPort7ModeRemoteAread-writecurrentNID Series card Port7 OAM: 0: Passive 1: Active
1.3.6.1.4.1.4756.20.501.20.1.388ColumnnidOAMPort7LoopBackRemoteAread-writecurrentNID Series card Port7 OAM: 0: Off 1: On
1.3.6.1.4.1.4756.20.501.20.1.389ColumnnidOAMPort7LinkMonitorRemoteAread-writecurrentNID Series card Port7 OAM Link Monitor: 0: Off 1: On
1.3.6.1.4.1.4756.20.501.20.1.390ColumnnidOAMPort7MIBRetrievalRemoteAread-writecurrentNID Series card Port7 OAM MIB Retrieval: 0: Off 1: On
1.3.6.1.4.1.4756.20.501.20.1.391ColumnnidOAMPort7LoopBackOPRemoteAread-writecurrentNID Series card Port7 OAM LoopBack operation: 0: On 1: Off
1.3.6.1.4.1.4756.20.501.20.1.392ColumnnidOAMPort8EnableRemoteAread-writecurrentNID Series card Port8 OAM: 0: Off 1: On
1.3.6.1.4.1.4756.20.501.20.1.393ColumnnidOAMPort8ModeRemoteAread-writecurrentNID Series card Port8 OAM: 0: Passive 1: Active
1.3.6.1.4.1.4756.20.501.20.1.394ColumnnidOAMPort8LoopBackRemoteAread-writecurrentNID Series card Port8 OAM: 0: Off 1: On
1.3.6.1.4.1.4756.20.501.20.1.395ColumnnidOAMPort8LinkMonitorRemoteAread-writecurrentNID Series card Port8 OAM Link Monitor: 0: Off 1: On
1.3.6.1.4.1.4756.20.501.20.1.396ColumnnidOAMPort8MIBRetrievalRemoteAread-writecurrentNID Series card Port8 OAM MIB Retrieval: 0: Off 1: On
1.3.6.1.4.1.4756.20.501.20.1.397ColumnnidOAMPort8LoopBackOPRemoteAread-writecurrentNID Series card Port8 OAM LoopBack operation: 0: On 1: Off
1.3.6.1.4.1.4756.20.501.20.1.398ColumnnidPort1EFEErrorWindowRemoteAread-writecurrentNID Series card Port1 Link Event Configuration: Error Frame Event - Error Window
1.3.6.1.4.1.4756.20.501.20.1.399ColumnnidPort1EFEErrorThresholdRemoteAread-writecurrentNID Series card Port1 Link Event Configuration: Error Frame Event - Error Threshold
1.3.6.1.4.1.4756.20.501.20.1.400ColumnnidPort1SPEEErrorWindowRemoteAread-writecurrentNID Series card Port1 Link Event Configuration: Symbol Period Error Event - Error Window
1.3.6.1.4.1.4756.20.501.20.1.401ColumnnidPort1SPEEErrorThresholdRemoteAread-writecurrentNID Series card Port1 Link Event Configuration: Symbol Period Error Event - Error Threshold
1.3.6.1.4.1.4756.20.501.20.1.402ColumnnidPort1SSEErrorWindowRemoteAread-writecurrentNID Series card Port1 Link Event Configuration: Seconds Summary Event - Error Window
1.3.6.1.4.1.4756.20.501.20.1.403ColumnnidPort1SSEErrorThresholdRemoteAread-writecurrentNID Series card Port1 Link Event Configuration: Seconds Summary Event - Error Threshold
1.3.6.1.4.1.4756.20.501.20.1.404ColumnnidPort2EFEErrorWindowRemoteAread-writecurrentNID Series card Port2 Link Event Configuration: Error Frame Event - Error Window
1.3.6.1.4.1.4756.20.501.20.1.405ColumnnidPort2EFEErrorThresholdRemoteAread-writecurrentNID Series card Port2 Link Event Configuration: Error Frame Event - Error Threshold
1.3.6.1.4.1.4756.20.501.20.1.406ColumnnidPort2SPEEErrorWindowRemoteAread-writecurrentNID Series card Port2 Link Event Configuration: Symbol Period Error Event - Error Window
1.3.6.1.4.1.4756.20.501.20.1.407ColumnnidPort2SPEEErrorThresholdRemoteAread-writecurrentNID Series card Port2 Link Event Configuration: Symbol Period Error Event - Error Threshold
1.3.6.1.4.1.4756.20.501.20.1.408ColumnnidPort2SSEErrorWindowRemoteAread-writecurrentNID Series card Port2 Link Event Configuration: Seconds Summary Event - Error Window
1.3.6.1.4.1.4756.20.501.20.1.409ColumnnidPort2SSEErrorThresholdRemoteAread-writecurrentNID Series card Port2 Link Event Configuration: Seconds Summary Event - Error Threshold
1.3.6.1.4.1.4756.20.501.20.1.410ColumnnidPort3EFEErrorWindowRemoteAread-writecurrentNID Series card Port3 Link Event Configuration: Error Frame Event - Error Window
1.3.6.1.4.1.4756.20.501.20.1.411ColumnnidPort3EFEErrorThresholdRemoteAread-writecurrentNID Series card Port3 Link Event Configuration: Error Frame Event - Error Threshold
1.3.6.1.4.1.4756.20.501.20.1.412ColumnnidPort3SPEEErrorWindowRemoteAread-writecurrentNID Series card Port3 Link Event Configuration: Symbol Period Error Event - Error Window
1.3.6.1.4.1.4756.20.501.20.1.413ColumnnidPort3SPEEErrorThresholdRemoteAread-writecurrentNID Series card Port3 Link Event Configuration: Symbol Period Error Event - Error Threshold
1.3.6.1.4.1.4756.20.501.20.1.414ColumnnidPort3SSEErrorWindowRemoteAread-writecurrentNID Series card Port3 Link Event Configuration: Seconds Summary Event - Error Window
1.3.6.1.4.1.4756.20.501.20.1.415ColumnnidPort3SSEErrorThresholdRemoteAread-writecurrentNID Series card Port3 Link Event Configuration: Seconds Summary Event - Error Threshold
1.3.6.1.4.1.4756.20.501.20.1.416ColumnnidPort4EFEErrorWindowRemoteAread-writecurrentNID Series card Port4 Link Event Configuration: Error Frame Event - Error Window
1.3.6.1.4.1.4756.20.501.20.1.417ColumnnidPort4EFEErrorThresholdRemoteAread-writecurrentNID Series card Port4 Link Event Configuration: Error Frame Event - Error Threshold
1.3.6.1.4.1.4756.20.501.20.1.418ColumnnidPort4SPEEErrorWindowRemoteAread-writecurrentNID Series card Port4 Link Event Configuration: Symbol Period Error Event - Error Window
1.3.6.1.4.1.4756.20.501.20.1.419ColumnnidPort4SPEEErrorThresholdRemoteAread-writecurrentNID Series card Port4 Link Event Configuration: Symbol Period Error Event - Error Threshold
1.3.6.1.4.1.4756.20.501.20.1.420ColumnnidPort4SSEErrorWindowRemoteAread-writecurrentNID Series card Port4 Link Event Configuration: Seconds Summary Event - Error Window
1.3.6.1.4.1.4756.20.501.20.1.421ColumnnidPort4SSEErrorThresholdRemoteAread-writecurrentNID Series card Port4 Link Event Configuration: Seconds Summary Event - Error Threshold
1.3.6.1.4.1.4756.20.501.20.1.422ColumnnidPort5EFEErrorWindowRemoteAread-writecurrentNID Series card Port5 Link Event Configuration: Error Frame Event - Error Window
1.3.6.1.4.1.4756.20.501.20.1.423ColumnnidPort5EFEErrorThresholdRemoteAread-writecurrentNID Series card Port5 Link Event Configuration: Error Frame Event - Error Threshold
1.3.6.1.4.1.4756.20.501.20.1.424ColumnnidPort5SPEEErrorWindowRemoteAread-writecurrentNID Series card Port5 Link Event Configuration: Symbol Period Error Event - Error Window
1.3.6.1.4.1.4756.20.501.20.1.425ColumnnidPort5SPEEErrorThresholdRemoteAread-writecurrentNID Series card Port5 Link Event Configuration: Symbol Period Error Event - Error Threshold
1.3.6.1.4.1.4756.20.501.20.1.426ColumnnidPort5SSEErrorWindowRemoteAread-writecurrentNID Series card Port5 Link Event Configuration: Seconds Summary Event - Error Window
1.3.6.1.4.1.4756.20.501.20.1.427ColumnnidPort5SSEErrorThresholdRemoteAread-writecurrentNID Series card Port5 Link Event Configuration: Seconds Summary Event - Error Threshold
1.3.6.1.4.1.4756.20.501.20.1.428ColumnnidPort6EFEErrorWindowRemoteAread-writecurrentNID Series card Port6 Link Event Configuration: Error Frame Event - Error Window
1.3.6.1.4.1.4756.20.501.20.1.429ColumnnidPort6EFEErrorThresholdRemoteAread-writecurrentNID Series card Port6 Link Event Configuration: Error Frame Event - Error Threshold
1.3.6.1.4.1.4756.20.501.20.1.430ColumnnidPort6SPEEErrorWindowRemoteAread-writecurrentNID Series card Port6 Link Event Configuration: Symbol Period Error Event - Error Window
1.3.6.1.4.1.4756.20.501.20.1.431ColumnnidPort6SPEEErrorThresholdRemoteAread-writecurrentNID Series card Port6 Link Event Configuration: Symbol Period Error Event - Error Threshold
1.3.6.1.4.1.4756.20.501.20.1.432ColumnnidPort6SSEErrorWindowRemoteAread-writecurrentNID Series card Port6 Link Event Configuration: Seconds Summary Event - Error Window
1.3.6.1.4.1.4756.20.501.20.1.433ColumnnidPort6SSEErrorThresholdRemoteAread-writecurrentNID Series card Port6 Link Event Configuration: Seconds Summary Event - Error Threshold
1.3.6.1.4.1.4756.20.501.20.1.434ColumnnidPort7EFEErrorWindowRemoteAread-writecurrentNID Series card Port7 Link Event Configuration: Error Frame Event - Error Window
1.3.6.1.4.1.4756.20.501.20.1.435ColumnnidPort7EFEErrorThresholdRemoteAread-writecurrentNID Series card Port7 Link Event Configuration: Error Frame Event - Error Threshold
1.3.6.1.4.1.4756.20.501.20.1.436ColumnnidPort7SPEEErrorWindowRemoteAread-writecurrentNID Series card Port7 Link Event Configuration: Symbol Period Error Event - Error Window
1.3.6.1.4.1.4756.20.501.20.1.437ColumnnidPort7SPEEErrorThresholdRemoteAread-writecurrentNID Series card Port7 Link Event Configuration: Symbol Period Error Event - Error Threshold
1.3.6.1.4.1.4756.20.501.20.1.438ColumnnidPort7SSEErrorWindowRemoteAread-writecurrentNID Series card Port7 Link Event Configuration: Seconds Summary Event - Error Window
1.3.6.1.4.1.4756.20.501.20.1.439ColumnnidPort7SSEErrorThresholdRemoteAread-writecurrentNID Series card Port7 Link Event Configuration: Seconds Summary Event - Error Threshold
1.3.6.1.4.1.4756.20.501.20.1.440ColumnnidPort8EFEErrorWindowRemoteAread-writecurrentNID Series card Port8 Link Event Configuration: Error Frame Event - Error Window
1.3.6.1.4.1.4756.20.501.20.1.441ColumnnidPort8EFEErrorThresholdRemoteAread-writecurrentNID Series card Port8 Link Event Configuration: Error Frame Event - Error Threshold
1.3.6.1.4.1.4756.20.501.20.1.442ColumnnidPort8SPEEErrorWindowRemoteAread-writecurrentNID Series card Port8 Link Event Configuration: Symbol Period Error Event - Error Window
1.3.6.1.4.1.4756.20.501.20.1.443ColumnnidPort8SPEEErrorThresholdRemoteAread-writecurrentNID Series card Port8 Link Event Configuration: Symbol Period Error Event - Error Threshold
1.3.6.1.4.1.4756.20.501.20.1.444ColumnnidPort8SSEErrorWindowRemoteAread-writecurrentNID Series card Port8 Link Event Configuration: Seconds Summary Event - Error Window
1.3.6.1.4.1.4756.20.501.20.1.445ColumnnidPort8SSEErrorThresholdRemoteAread-writecurrentNID Series card Port8 Link Event Configuration: Seconds Summary Event - Error Threshold
1.3.6.1.4.1.4756.20.501.20.1.446ColumnnidPort1RxOAMInfoPDURemoteAread-onlycurrentNID Series card Port1 Detailed Link OAM Statistics: Rx OAM Information PDU's
1.3.6.1.4.1.4756.20.501.20.1.447ColumnnidPort1RxUniqueErrorEventRemoteAread-onlycurrentNID Series card Port1 Detailed Link OAM Statistics: Rx Unique Error Event Notificatio
1.3.6.1.4.1.4756.20.501.20.1.448ColumnnidPort1RxDuplicateErrorEventRemoteAread-onlycurrentNID Series card Port1 Detailed Link OAM Statistics: Rx Duplicate Error Event Notification
1.3.6.1.4.1.4756.20.501.20.1.449ColumnnidPort1RxLoopBackControlRemoteAread-onlycurrentNID Series card Port1 Detailed Link OAM Statistics: Rx Loopback Control
1.3.6.1.4.1.4756.20.501.20.1.450ColumnnidPort1RxVariableRequestRemoteAread-onlycurrentNID Series card Port1 Detailed Link OAM Statistics: Rx Variable Request
1.3.6.1.4.1.4756.20.501.20.1.451ColumnnidPort1RxVariableResponseRemoteAread-onlycurrentNID Series card Port1 Detailed Link OAM Statistics: Rx Variable Response
1.3.6.1.4.1.4756.20.501.20.1.452ColumnnidPort1RxOrgSpecificPDURemoteAread-onlycurrentNID Series card Port1 Detailed Link OAM Statistics: Rx Org Specific PDU's
1.3.6.1.4.1.4756.20.501.20.1.453ColumnnidPort1RxUnsupportedCodesRemoteAread-onlycurrentNID Series card Port1 Detailed Link OAM Statistics: Rx Unsupported Codes
1.3.6.1.4.1.4756.20.501.20.1.454ColumnnidPort1RxLinkFaultPDURemoteAread-onlycurrentNID Series card Port1 Detailed Link OAM Statistics: Rx Link Fault PDU's
1.3.6.1.4.1.4756.20.501.20.1.455ColumnnidPort1RxDyingGaspRemoteAread-onlycurrentNID Series card Port1 Detailed Link OAM Statistics: Rx Dying Gasp
1.3.6.1.4.1.4756.20.501.20.1.456ColumnnidPort1RxCriticalEventPDURemoteAread-onlycurrentNID Series card Port1 Detailed Link OAM Statistics: Rx Dying Gasp
1.3.6.1.4.1.4756.20.501.20.1.457ColumnnidPort1TxOAMInfoPDURemoteAread-onlycurrentNID Series card Port1 Detailed Link OAM Statistics: Tx OAM Information PDU's
1.3.6.1.4.1.4756.20.501.20.1.458ColumnnidPort1TxUniqueErrorEventRemoteAread-onlycurrentNID Series card Port1 Detailed Link OAM Statistics: Tx Unique Error Event Notificatio
1.3.6.1.4.1.4756.20.501.20.1.459ColumnnidPort1TxDuplicateErrorEventRemoteAread-onlycurrentNID Series card Port1 Detailed Link OAM Statistics: Tx Duplicate Error Event Notification
1.3.6.1.4.1.4756.20.501.20.1.460ColumnnidPort1TxLoopBackControlRemoteAread-onlycurrentNID Series card Port1 Detailed Link OAM Statistics: Tx Loopback Control
1.3.6.1.4.1.4756.20.501.20.1.461ColumnnidPort1TxVariableRequestRemoteAread-onlycurrentNID Series card Port1 Detailed Link OAM Statistics: Tx Variable Request
1.3.6.1.4.1.4756.20.501.20.1.462ColumnnidPort1TxVariableResponseRemoteAread-onlycurrentNID Series card Port1 Detailed Link OAM Statistics: Tx Variable Response
1.3.6.1.4.1.4756.20.501.20.1.463ColumnnidPort1TxOrgSpecificPDURemoteAread-onlycurrentNID Series card Port1 Detailed Link OAM Statistics: Tx Org Specific PDU's
1.3.6.1.4.1.4756.20.501.20.1.464ColumnnidPort1TxUnsupportedCodesRemoteAread-onlycurrentNID Series card Port1 Detailed Link OAM Statistics: Tx Unsupported Codes
1.3.6.1.4.1.4756.20.501.20.1.465ColumnnidPort1TxLinkFaultPDURemoteAread-onlycurrentNID Series card Port1 Detailed Link OAM Statistics: Tx Link Fault PDU's
1.3.6.1.4.1.4756.20.501.20.1.466ColumnnidPort1TxDyingGaspRemoteAread-onlycurrentNID Series card Port1 Detailed Link OAM Statistics: Tx Dying Gasp
1.3.6.1.4.1.4756.20.501.20.1.467ColumnnidPort1TxCriticalEventPDURemoteAread-onlycurrentNID Series card Port1 Detailed Link OAM Statistics: Tx Dying Gasp
1.3.6.1.4.1.4756.20.501.20.1.468ColumnnidPort2RxOAMInfoPDURemoteAread-onlycurrentNID Series card Port2 Detailed Link OAM Statistics: Rx OAM Information PDU's
1.3.6.1.4.1.4756.20.501.20.1.469ColumnnidPort2RxUniqueErrorEventRemoteAread-onlycurrentNID Series card Port2 Detailed Link OAM Statistics: Rx Unique Error Event Notificatio
1.3.6.1.4.1.4756.20.501.20.1.470ColumnnidPort2RxDuplicateErrorEventRemoteAread-onlycurrentNID Series card Port2 Detailed Link OAM Statistics: Rx Duplicate Error Event Notification
1.3.6.1.4.1.4756.20.501.20.1.471ColumnnidPort2RxLoopBackControlRemoteAread-onlycurrentNID Series card Port2 Detailed Link OAM Statistics: Rx Loopback Control
1.3.6.1.4.1.4756.20.501.20.1.472ColumnnidPort2RxVariableRequestRemoteAread-onlycurrentNID Series card Port2 Detailed Link OAM Statistics: Rx Variable Request
1.3.6.1.4.1.4756.20.501.20.1.473ColumnnidPort2RxVariableResponseRemoteAread-onlycurrentNID Series card Port2 Detailed Link OAM Statistics: Rx Variable Response
1.3.6.1.4.1.4756.20.501.20.1.474ColumnnidPort2RxOrgSpecificPDURemoteAread-onlycurrentNID Series card Port2 Detailed Link OAM Statistics: Rx Org Specific PDU's
1.3.6.1.4.1.4756.20.501.20.1.475ColumnnidPort2RxUnsupportedCodesRemoteAread-onlycurrentNID Series card Port2 Detailed Link OAM Statistics: Rx Unsupported Codes
1.3.6.1.4.1.4756.20.501.20.1.476ColumnnidPort2RxLinkFaultPDURemoteAread-onlycurrentNID Series card Port2 Detailed Link OAM Statistics: Rx Link Fault PDU's
1.3.6.1.4.1.4756.20.501.20.1.477ColumnnidPort2RxDyingGaspRemoteAread-onlycurrentNID Series card Port2 Detailed Link OAM Statistics: Rx Dying Gasp
1.3.6.1.4.1.4756.20.501.20.1.478ColumnnidPort2RxCriticalEventPDURemoteAread-onlycurrentNID Series card Port2 Detailed Link OAM Statistics: Rx Dying Gasp
1.3.6.1.4.1.4756.20.501.20.1.479ColumnnidPort2TxOAMInfoPDURemoteAread-onlycurrentNID Series card Port2 Detailed Link OAM Statistics: Tx OAM Information PDU's
1.3.6.1.4.1.4756.20.501.20.1.480ColumnnidPort2TxUniqueErrorEventRemoteAread-onlycurrentNID Series card Port2 Detailed Link OAM Statistics: Tx Unique Error Event Notificatio
1.3.6.1.4.1.4756.20.501.20.1.481ColumnnidPort2TxDuplicateErrorEventRemoteAread-onlycurrentNID Series card Port2 Detailed Link OAM Statistics: Tx Duplicate Error Event Notification
1.3.6.1.4.1.4756.20.501.20.1.482ColumnnidPort2TxLoopBackControlRemoteAread-onlycurrentNID Series card Port2 Detailed Link OAM Statistics: Tx Loopback Control
1.3.6.1.4.1.4756.20.501.20.1.483ColumnnidPort2TxVariableRequestRemoteAread-onlycurrentNID Series card Port2 Detailed Link OAM Statistics: Tx Variable Request
1.3.6.1.4.1.4756.20.501.20.1.484ColumnnidPort2TxVariableResponseRemoteAread-onlycurrentNID Series card Port2 Detailed Link OAM Statistics: Tx Variable Response
1.3.6.1.4.1.4756.20.501.20.1.485ColumnnidPort2TxOrgSpecificPDURemoteAread-onlycurrentNID Series card Port2 Detailed Link OAM Statistics: Tx Org Specific PDU's
1.3.6.1.4.1.4756.20.501.20.1.486ColumnnidPort2TxUnsupportedCodesRemoteAread-onlycurrentNID Series card Port2 Detailed Link OAM Statistics: Tx Unsupported Codes
1.3.6.1.4.1.4756.20.501.20.1.487ColumnnidPort2TxLinkFaultPDURemoteAread-onlycurrentNID Series card Port2 Detailed Link OAM Statistics: Tx Link Fault PDU's
1.3.6.1.4.1.4756.20.501.20.1.488ColumnnidPort2TxDyingGaspRemoteAread-onlycurrentNID Series card Port2 Detailed Link OAM Statistics: Tx Dying Gasp
1.3.6.1.4.1.4756.20.501.20.1.489ColumnnidPort2TxCriticalEventPDURemoteAread-onlycurrentNID Series card Port2 Detailed Link OAM Statistics: Tx Dying Gasp
1.3.6.1.4.1.4756.20.501.20.1.490ColumnnidPort3RxOAMInfoPDURemoteAread-onlycurrentNID Series card Port3 Detailed Link OAM Statistics: Rx OAM Information PDU's
1.3.6.1.4.1.4756.20.501.20.1.491ColumnnidPort3RxUniqueErrorEventRemoteAread-onlycurrentNID Series card Port3 Detailed Link OAM Statistics: Rx Unique Error Event Notificatio
1.3.6.1.4.1.4756.20.501.20.1.492ColumnnidPort3RxDuplicateErrorEventRemoteAread-onlycurrentNID Series card Port3 Detailed Link OAM Statistics: Rx Duplicate Error Event Notification
1.3.6.1.4.1.4756.20.501.20.1.493ColumnnidPort3RxLoopBackControlRemoteAread-onlycurrentNID Series card Port3 Detailed Link OAM Statistics: Rx Loopback Control
1.3.6.1.4.1.4756.20.501.20.1.494ColumnnidPort3RxVariableRequestRemoteAread-onlycurrentNID Series card Port3 Detailed Link OAM Statistics: Rx Variable Request
1.3.6.1.4.1.4756.20.501.20.1.495ColumnnidPort3RxVariableResponseRemoteAread-onlycurrentNID Series card Port3 Detailed Link OAM Statistics: Rx Variable Response
1.3.6.1.4.1.4756.20.501.20.1.496ColumnnidPort3RxOrgSpecificPDURemoteAread-onlycurrentNID Series card Port3 Detailed Link OAM Statistics: Rx Org Specific PDU's
1.3.6.1.4.1.4756.20.501.20.1.497ColumnnidPort3RxUnsupportedCodesRemoteAread-onlycurrentNID Series card Port3 Detailed Link OAM Statistics: Rx Unsupported Codes
1.3.6.1.4.1.4756.20.501.20.1.498ColumnnidPort3RxLinkFaultPDURemoteAread-onlycurrentNID Series card Port3 Detailed Link OAM Statistics: Rx Link Fault PDU's
1.3.6.1.4.1.4756.20.501.20.1.499ColumnnidPort3RxDyingGaspRemoteAread-onlycurrentNID Series card Port3 Detailed Link OAM Statistics: Rx Dying Gasp
1.3.6.1.4.1.4756.20.501.20.1.500ColumnnidPort3RxCriticalEventPDURemoteAread-onlycurrentNID Series card Port3 Detailed Link OAM Statistics: Rx Dying Gasp
1.3.6.1.4.1.4756.20.501.20.1.501ColumnnidPort3TxOAMInfoPDURemoteAread-onlycurrentNID Series card Port3 Detailed Link OAM Statistics: Tx OAM Information PDU's
1.3.6.1.4.1.4756.20.501.20.1.502ColumnnidPort3TxUniqueErrorEventRemoteAread-onlycurrentNID Series card Port3 Detailed Link OAM Statistics: Tx Unique Error Event Notificatio
1.3.6.1.4.1.4756.20.501.20.1.503ColumnnidPort3TxDuplicateErrorEventRemoteAread-onlycurrentNID Series card Port3 Detailed Link OAM Statistics: Tx Duplicate Error Event Notification
1.3.6.1.4.1.4756.20.501.20.1.504ColumnnidPort3TxLoopBackControlRemoteAread-onlycurrentNID Series card Port3 Detailed Link OAM Statistics: Tx Loopback Control
1.3.6.1.4.1.4756.20.501.20.1.505ColumnnidPort3TxVariableRequestRemoteAread-onlycurrentNID Series card Port3 Detailed Link OAM Statistics: Tx Variable Request
1.3.6.1.4.1.4756.20.501.20.1.506ColumnnidPort3TxVariableResponseRemoteAread-onlycurrentNID Series card Port3 Detailed Link OAM Statistics: Tx Variable Response
1.3.6.1.4.1.4756.20.501.20.1.507ColumnnidPort3TxOrgSpecificPDURemoteAread-onlycurrentNID Series card Port3 Detailed Link OAM Statistics: Tx Org Specific PDU's
1.3.6.1.4.1.4756.20.501.20.1.508ColumnnidPort3TxUnsupportedCodesRemoteAread-onlycurrentNID Series card Port3 Detailed Link OAM Statistics: Tx Unsupported Codes
1.3.6.1.4.1.4756.20.501.20.1.509ColumnnidPort3TxLinkFaultPDURemoteAread-onlycurrentNID Series card Port3 Detailed Link OAM Statistics: Tx Link Fault PDU's
1.3.6.1.4.1.4756.20.501.20.1.510ColumnnidPort3TxDyingGaspRemoteAread-onlycurrentNID Series card Port3 Detailed Link OAM Statistics: Tx Dying Gasp
1.3.6.1.4.1.4756.20.501.20.1.511ColumnnidPort3TxCriticalEventPDURemoteAread-onlycurrentNID Series card Port3 Detailed Link OAM Statistics: Tx Dying Gasp
1.3.6.1.4.1.4756.20.501.20.1.512ColumnnidPort4RxOAMInfoPDURemoteAread-onlycurrentNID Series card Port4 Detailed Link OAM Statistics: Rx OAM Information PDU's
1.3.6.1.4.1.4756.20.501.20.1.513ColumnnidPort4RxUniqueErrorEventRemoteAread-onlycurrentNID Series card Port4 Detailed Link OAM Statistics: Rx Unique Error Event Notificatio
1.3.6.1.4.1.4756.20.501.20.1.514ColumnnidPort4RxDuplicateErrorEventRemoteAread-onlycurrentNID Series card Port4 Detailed Link OAM Statistics: Rx Duplicate Error Event Notification
1.3.6.1.4.1.4756.20.501.20.1.515ColumnnidPort4RxLoopBackControlRemoteAread-onlycurrentNID Series card Port4 Detailed Link OAM Statistics: Rx Loopback Control
1.3.6.1.4.1.4756.20.501.20.1.516ColumnnidPort4RxVariableRequestRemoteAread-onlycurrentNID Series card Port4 Detailed Link OAM Statistics: Rx Variable Request
1.3.6.1.4.1.4756.20.501.20.1.517ColumnnidPort4RxVariableResponseRemoteAread-onlycurrentNID Series card Port4 Detailed Link OAM Statistics: Rx Variable Response
1.3.6.1.4.1.4756.20.501.20.1.518ColumnnidPort4RxOrgSpecificPDURemoteAread-onlycurrentNID Series card Port4 Detailed Link OAM Statistics: Rx Org Specific PDU's
1.3.6.1.4.1.4756.20.501.20.1.519ColumnnidPort4RxUnsupportedCodesRemoteAread-onlycurrentNID Series card Port4 Detailed Link OAM Statistics: Rx Unsupported Codes
1.3.6.1.4.1.4756.20.501.20.1.520ColumnnidPort4RxLinkFaultPDURemoteAread-onlycurrentNID Series card Port4 Detailed Link OAM Statistics: Rx Link Fault PDU's
1.3.6.1.4.1.4756.20.501.20.1.521ColumnnidPort4RxDyingGaspRemoteAread-onlycurrentNID Series card Port4 Detailed Link OAM Statistics: Rx Dying Gasp
1.3.6.1.4.1.4756.20.501.20.1.522ColumnnidPort4RxCriticalEventPDURemoteAread-onlycurrentNID Series card Port4 Detailed Link OAM Statistics: Rx Dying Gasp
1.3.6.1.4.1.4756.20.501.20.1.523ColumnnidPort4TxOAMInfoPDURemoteAread-onlycurrentNID Series card Port4 Detailed Link OAM Statistics: Tx OAM Information PDU's
1.3.6.1.4.1.4756.20.501.20.1.524ColumnnidPort4TxUniqueErrorEventRemoteAread-onlycurrentNID Series card Port4 Detailed Link OAM Statistics: Tx Unique Error Event Notificatio
1.3.6.1.4.1.4756.20.501.20.1.525ColumnnidPort4TxDuplicateErrorEventRemoteAread-onlycurrentNID Series card Port4 Detailed Link OAM Statistics: Tx Duplicate Error Event Notification
1.3.6.1.4.1.4756.20.501.20.1.526ColumnnidPort4TxLoopBackControlRemoteAread-onlycurrentNID Series card Port4 Detailed Link OAM Statistics: Tx Loopback Control
1.3.6.1.4.1.4756.20.501.20.1.527ColumnnidPort4TxVariableRequestRemoteAread-onlycurrentNID Series card Port4 Detailed Link OAM Statistics: Tx Variable Request
1.3.6.1.4.1.4756.20.501.20.1.528ColumnnidPort4TxVariableResponseRemoteAread-onlycurrentNID Series card Port4 Detailed Link OAM Statistics: Tx Variable Response
1.3.6.1.4.1.4756.20.501.20.1.529ColumnnidPort4TxOrgSpecificPDURemoteAread-onlycurrentNID Series card Port4 Detailed Link OAM Statistics: Tx Org Specific PDU's
1.3.6.1.4.1.4756.20.501.20.1.530ColumnnidPort4TxUnsupportedCodesRemoteAread-onlycurrentNID Series card Port4 Detailed Link OAM Statistics: Tx Unsupported Codes
1.3.6.1.4.1.4756.20.501.20.1.531ColumnnidPort4TxLinkFaultPDURemoteAread-onlycurrentNID Series card Port4 Detailed Link OAM Statistics: Tx Link Fault PDU's
1.3.6.1.4.1.4756.20.501.20.1.532ColumnnidPort4TxDyingGaspRemoteAread-onlycurrentNID Series card Port4 Detailed Link OAM Statistics: Tx Dying Gasp
1.3.6.1.4.1.4756.20.501.20.1.533ColumnnidPort4TxCriticalEventPDURemoteAread-onlycurrentNID Series card Port4 Detailed Link OAM Statistics: Tx Dying Gasp
1.3.6.1.4.1.4756.20.501.20.1.534ColumnnidPort5RxOAMInfoPDURemoteAread-onlycurrentNID Series card Port5 Detailed Link OAM Statistics: Rx OAM Information PDU's
1.3.6.1.4.1.4756.20.501.20.1.535ColumnnidPort5RxUniqueErrorEventRemoteAread-onlycurrentNID Series card Port5 Detailed Link OAM Statistics: Rx Unique Error Event Notificatio
1.3.6.1.4.1.4756.20.501.20.1.536ColumnnidPort5RxDuplicateErrorEventRemoteAread-onlycurrentNID Series card Port5 Detailed Link OAM Statistics: Rx Duplicate Error Event Notification
1.3.6.1.4.1.4756.20.501.20.1.537ColumnnidPort5RxLoopBackControlRemoteAread-onlycurrentNID Series card Port5 Detailed Link OAM Statistics: Rx Loopback Control
1.3.6.1.4.1.4756.20.501.20.1.538ColumnnidPort5RxVariableRequestRemoteAread-onlycurrentNID Series card Port5 Detailed Link OAM Statistics: Rx Variable Request
1.3.6.1.4.1.4756.20.501.20.1.539ColumnnidPort5RxVariableResponseRemoteAread-onlycurrentNID Series card Port5 Detailed Link OAM Statistics: Rx Variable Response
1.3.6.1.4.1.4756.20.501.20.1.540ColumnnidPort5RxOrgSpecificPDURemoteAread-onlycurrentNID Series card Port5 Detailed Link OAM Statistics: Rx Org Specific PDU's
1.3.6.1.4.1.4756.20.501.20.1.541ColumnnidPort5RxUnsupportedCodesRemoteAread-onlycurrentNID Series card Port5 Detailed Link OAM Statistics: Rx Unsupported Codes
1.3.6.1.4.1.4756.20.501.20.1.542ColumnnidPort5RxLinkFaultPDURemoteAread-onlycurrentNID Series card Port5 Detailed Link OAM Statistics: Rx Link Fault PDU's
1.3.6.1.4.1.4756.20.501.20.1.543ColumnnidPort5RxDyingGaspRemoteAread-onlycurrentNID Series card Port5 Detailed Link OAM Statistics: Rx Dying Gasp
1.3.6.1.4.1.4756.20.501.20.1.544ColumnnidPort5RxCriticalEventPDURemoteAread-onlycurrentNID Series card Port5 Detailed Link OAM Statistics: Rx Dying Gasp
1.3.6.1.4.1.4756.20.501.20.1.545ColumnnidPort5TxOAMInfoPDURemoteAread-onlycurrentNID Series card Port5 Detailed Link OAM Statistics: Tx OAM Information PDU's
1.3.6.1.4.1.4756.20.501.20.1.546ColumnnidPort5TxUniqueErrorEventRemoteAread-onlycurrentNID Series card Port5 Detailed Link OAM Statistics: Tx Unique Error Event Notificatio
1.3.6.1.4.1.4756.20.501.20.1.547ColumnnidPort5TxDuplicateErrorEventRemoteAread-onlycurrentNID Series card Port5 Detailed Link OAM Statistics: Tx Duplicate Error Event Notification
1.3.6.1.4.1.4756.20.501.20.1.548ColumnnidPort5TxLoopBackControlRemoteAread-onlycurrentNID Series card Port5 Detailed Link OAM Statistics: Tx Loopback Control
1.3.6.1.4.1.4756.20.501.20.1.549ColumnnidPort5TxVariableRequestRemoteAread-onlycurrentNID Series card Port5 Detailed Link OAM Statistics: Tx Variable Request
1.3.6.1.4.1.4756.20.501.20.1.550ColumnnidPort5TxVariableResponseRemoteAread-onlycurrentNID Series card Port5 Detailed Link OAM Statistics: Tx Variable Response
1.3.6.1.4.1.4756.20.501.20.1.551ColumnnidPort5TxOrgSpecificPDURemoteAread-onlycurrentNID Series card Port5 Detailed Link OAM Statistics: Tx Org Specific PDU's
1.3.6.1.4.1.4756.20.501.20.1.552ColumnnidPort5TxUnsupportedCodesRemoteAread-onlycurrentNID Series card Port5 Detailed Link OAM Statistics: Tx Unsupported Codes
1.3.6.1.4.1.4756.20.501.20.1.553ColumnnidPort5TxLinkFaultPDURemoteAread-onlycurrentNID Series card Port5 Detailed Link OAM Statistics: Tx Link Fault PDU's
1.3.6.1.4.1.4756.20.501.20.1.554ColumnnidPort5TxDyingGaspRemoteAread-onlycurrentNID Series card Port5 Detailed Link OAM Statistics: Tx Dying Gasp
1.3.6.1.4.1.4756.20.501.20.1.555ColumnnidPort5TxCriticalEventPDURemoteAread-onlycurrentNID Series card Port5 Detailed Link OAM Statistics: Tx Dying Gasp
1.3.6.1.4.1.4756.20.501.20.1.556ColumnnidPort6RxOAMInfoPDURemoteAread-onlycurrentNID Series card Port6 Detailed Link OAM Statistics: Rx OAM Information PDU's
1.3.6.1.4.1.4756.20.501.20.1.557ColumnnidPort6RxUniqueErrorEventRemoteAread-onlycurrentNID Series card Port6 Detailed Link OAM Statistics: Rx Unique Error Event Notificatio
1.3.6.1.4.1.4756.20.501.20.1.558ColumnnidPort6RxDuplicateErrorEventRemoteAread-onlycurrentNID Series card Port6 Detailed Link OAM Statistics: Rx Duplicate Error Event Notification
1.3.6.1.4.1.4756.20.501.20.1.559ColumnnidPort6RxLoopBackControlRemoteAread-onlycurrentNID Series card Port6 Detailed Link OAM Statistics: Rx Loopback Control
1.3.6.1.4.1.4756.20.501.20.1.560ColumnnidPort6RxVariableRequestRemoteAread-onlycurrentNID Series card Port6 Detailed Link OAM Statistics: Rx Variable Request
1.3.6.1.4.1.4756.20.501.20.1.561ColumnnidPort6RxVariableResponseRemoteAread-onlycurrentNID Series card Port6 Detailed Link OAM Statistics: Rx Variable Response
1.3.6.1.4.1.4756.20.501.20.1.562ColumnnidPort6RxOrgSpecificPDURemoteAread-onlycurrentNID Series card Port6 Detailed Link OAM Statistics: Rx Org Specific PDU's
1.3.6.1.4.1.4756.20.501.20.1.563ColumnnidPort6RxUnsupportedCodesRemoteAread-onlycurrentNID Series card Port6 Detailed Link OAM Statistics: Rx Unsupported Codes
1.3.6.1.4.1.4756.20.501.20.1.564ColumnnidPort6RxLinkFaultPDURemoteAread-onlycurrentNID Series card Port6 Detailed Link OAM Statistics: Rx Link Fault PDU's
1.3.6.1.4.1.4756.20.501.20.1.565ColumnnidPort6RxDyingGaspRemoteAread-onlycurrentNID Series card Port6 Detailed Link OAM Statistics: Rx Dying Gasp
1.3.6.1.4.1.4756.20.501.20.1.566ColumnnidPort6RxCriticalEventPDURemoteAread-onlycurrentNID Series card Port6 Detailed Link OAM Statistics: Rx Dying Gasp
1.3.6.1.4.1.4756.20.501.20.1.567ColumnnidPort6TxOAMInfoPDURemoteAread-onlycurrentNID Series card Port6 Detailed Link OAM Statistics: Tx OAM Information PDU's
1.3.6.1.4.1.4756.20.501.20.1.568ColumnnidPort6TxUniqueErrorEventRemoteAread-onlycurrentNID Series card Port6 Detailed Link OAM Statistics: Tx Unique Error Event Notificatio
1.3.6.1.4.1.4756.20.501.20.1.569ColumnnidPort6TxDuplicateErrorEventRemoteAread-onlycurrentNID Series card Port6 Detailed Link OAM Statistics: Tx Duplicate Error Event Notification
1.3.6.1.4.1.4756.20.501.20.1.570ColumnnidPort6TxLoopBackControlRemoteAread-onlycurrentNID Series card Port6 Detailed Link OAM Statistics: Tx Loopback Control
1.3.6.1.4.1.4756.20.501.20.1.571ColumnnidPort6TxVariableRequestRemoteAread-onlycurrentNID Series card Port6 Detailed Link OAM Statistics: Tx Variable Request
1.3.6.1.4.1.4756.20.501.20.1.572ColumnnidPort6TxVariableResponseRemoteAread-onlycurrentNID Series card Port6 Detailed Link OAM Statistics: Tx Variable Response
1.3.6.1.4.1.4756.20.501.20.1.573ColumnnidPort6TxOrgSpecificPDURemoteAread-onlycurrentNID Series card Port6 Detailed Link OAM Statistics: Tx Org Specific PDU's
1.3.6.1.4.1.4756.20.501.20.1.574ColumnnidPort6TxUnsupportedCodesRemoteAread-onlycurrentNID Series card Port6 Detailed Link OAM Statistics: Tx Unsupported Codes
1.3.6.1.4.1.4756.20.501.20.1.575ColumnnidPort6TxLinkFaultPDURemoteAread-onlycurrentNID Series card Port6 Detailed Link OAM Statistics: Tx Link Fault PDU's
1.3.6.1.4.1.4756.20.501.20.1.576ColumnnidPort6TxDyingGaspRemoteAread-onlycurrentNID Series card Port6 Detailed Link OAM Statistics: Tx Dying Gasp
1.3.6.1.4.1.4756.20.501.20.1.577ColumnnidPort6TxCriticalEventPDURemoteAread-onlycurrentNID Series card Port6 Detailed Link OAM Statistics: Tx Dying Gasp
1.3.6.1.4.1.4756.20.501.20.1.578ColumnnidPort7RxOAMInfoPDURemoteAread-onlycurrentNID Series card Port7 Detailed Link OAM Statistics: Rx OAM Information PDU's
1.3.6.1.4.1.4756.20.501.20.1.579ColumnnidPort7RxUniqueErrorEventRemoteAread-onlycurrentNID Series card Port7 Detailed Link OAM Statistics: Rx Unique Error Event Notificatio
1.3.6.1.4.1.4756.20.501.20.1.580ColumnnidPort7RxDuplicateErrorEventRemoteAread-onlycurrentNID Series card Port7 Detailed Link OAM Statistics: Rx Duplicate Error Event Notification
1.3.6.1.4.1.4756.20.501.20.1.581ColumnnidPort7RxLoopBackControlRemoteAread-onlycurrentNID Series card Port7 Detailed Link OAM Statistics: Rx Loopback Control
1.3.6.1.4.1.4756.20.501.20.1.582ColumnnidPort7RxVariableRequestRemoteAread-onlycurrentNID Series card Port7 Detailed Link OAM Statistics: Rx Variable Request
1.3.6.1.4.1.4756.20.501.20.1.583ColumnnidPort7RxVariableResponseRemoteAread-onlycurrentNID Series card Port7 Detailed Link OAM Statistics: Rx Variable Response
1.3.6.1.4.1.4756.20.501.20.1.584ColumnnidPort7RxOrgSpecificPDURemoteAread-onlycurrentNID Series card Port7 Detailed Link OAM Statistics: Rx Org Specific PDU's
1.3.6.1.4.1.4756.20.501.20.1.585ColumnnidPort7RxUnsupportedCodesRemoteAread-onlycurrentNID Series card Port7 Detailed Link OAM Statistics: Rx Unsupported Codes
1.3.6.1.4.1.4756.20.501.20.1.586ColumnnidPort7RxLinkFaultPDURemoteAread-onlycurrentNID Series card Port7 Detailed Link OAM Statistics: Rx Link Fault PDU's
1.3.6.1.4.1.4756.20.501.20.1.587ColumnnidPort7RxDyingGaspRemoteAread-onlycurrentNID Series card Port7 Detailed Link OAM Statistics: Rx Dying Gasp
1.3.6.1.4.1.4756.20.501.20.1.588ColumnnidPort7RxCriticalEventPDURemoteAread-onlycurrentNID Series card Port7 Detailed Link OAM Statistics: Rx Dying Gasp
1.3.6.1.4.1.4756.20.501.20.1.589ColumnnidPort7TxOAMInfoPDURemoteAread-onlycurrentNID Series card Port7 Detailed Link OAM Statistics: Tx OAM Information PDU's
1.3.6.1.4.1.4756.20.501.20.1.590ColumnnidPort7TxUniqueErrorEventRemoteAread-onlycurrentNID Series card Port7 Detailed Link OAM Statistics: Tx Unique Error Event Notificatio
1.3.6.1.4.1.4756.20.501.20.1.591ColumnnidPort7TxDuplicateErrorEventRemoteAread-onlycurrentNID Series card Port7 Detailed Link OAM Statistics: Tx Duplicate Error Event Notification
1.3.6.1.4.1.4756.20.501.20.1.592ColumnnidPort7TxLoopBackControlRemoteAread-onlycurrentNID Series card Port7 Detailed Link OAM Statistics: Tx Loopback Control
1.3.6.1.4.1.4756.20.501.20.1.593ColumnnidPort7TxVariableRequestRemoteAread-onlycurrentNID Series card Port7 Detailed Link OAM Statistics: Tx Variable Request
1.3.6.1.4.1.4756.20.501.20.1.594ColumnnidPort7TxVariableResponseRemoteAread-onlycurrentNID Series card Port7 Detailed Link OAM Statistics: Tx Variable Response
1.3.6.1.4.1.4756.20.501.20.1.595ColumnnidPort7TxOrgSpecificPDURemoteAread-onlycurrentNID Series card Port7 Detailed Link OAM Statistics: Tx Org Specific PDU's
1.3.6.1.4.1.4756.20.501.20.1.596ColumnnidPort7TxUnsupportedCodesRemoteAread-onlycurrentNID Series card Port7 Detailed Link OAM Statistics: Tx Unsupported Codes
1.3.6.1.4.1.4756.20.501.20.1.597ColumnnidPort7TxLinkFaultPDURemoteAread-onlycurrentNID Series card Port7 Detailed Link OAM Statistics: Tx Link Fault PDU's
1.3.6.1.4.1.4756.20.501.20.1.598ColumnnidPort7TxDyingGaspRemoteAread-onlycurrentNID Series card Port7 Detailed Link OAM Statistics: Tx Dying Gasp
1.3.6.1.4.1.4756.20.501.20.1.599ColumnnidPort7TxCriticalEventPDURemoteAread-onlycurrentNID Series card Port7 Detailed Link OAM Statistics: Tx Dying Gasp
1.3.6.1.4.1.4756.20.501.20.1.600ColumnnidPort8RxOAMInfoPDURemoteAread-onlycurrentNID Series card Port8 Detailed Link OAM Statistics: Rx OAM Information PDU's
1.3.6.1.4.1.4756.20.501.20.1.601ColumnnidPort8RxUniqueErrorEventRemoteAread-onlycurrentNID Series card Port8 Detailed Link OAM Statistics: Rx Unique Error Event Notificatio
1.3.6.1.4.1.4756.20.501.20.1.602ColumnnidPort8RxDuplicateErrorEventRemoteAread-onlycurrentNID Series card Port8 Detailed Link OAM Statistics: Rx Duplicate Error Event Notification
1.3.6.1.4.1.4756.20.501.20.1.603ColumnnidPort8RxLoopBackControlRemoteAread-onlycurrentNID Series card Port8 Detailed Link OAM Statistics: Rx Loopback Control
1.3.6.1.4.1.4756.20.501.20.1.604ColumnnidPort8RxVariableRequestRemoteAread-onlycurrentNID Series card Port8 Detailed Link OAM Statistics: Rx Variable Request
1.3.6.1.4.1.4756.20.501.20.1.605ColumnnidPort8RxVariableResponseRemoteAread-onlycurrentNID Series card Port8 Detailed Link OAM Statistics: Rx Variable Response
1.3.6.1.4.1.4756.20.501.20.1.606ColumnnidPort8RxOrgSpecificPDURemoteAread-onlycurrentNID Series card Port8 Detailed Link OAM Statistics: Rx Org Specific PDU's
1.3.6.1.4.1.4756.20.501.20.1.607ColumnnidPort8RxUnsupportedCodesRemoteAread-onlycurrentNID Series card Port8 Detailed Link OAM Statistics: Rx Unsupported Codes
1.3.6.1.4.1.4756.20.501.20.1.608ColumnnidPort8RxLinkFaultPDURemoteAread-onlycurrentNID Series card Port8 Detailed Link OAM Statistics: Rx Link Fault PDU's
1.3.6.1.4.1.4756.20.501.20.1.609ColumnnidPort8RxDyingGaspRemoteAread-onlycurrentNID Series card Port8 Detailed Link OAM Statistics: Rx Dying Gasp
1.3.6.1.4.1.4756.20.501.20.1.610ColumnnidPort8RxCriticalEventPDURemoteAread-onlycurrentNID Series card Port8 Detailed Link OAM Statistics: Rx Dying Gasp
1.3.6.1.4.1.4756.20.501.20.1.611ColumnnidPort8TxOAMInfoPDURemoteAread-onlycurrentNID Series card Port8 Detailed Link OAM Statistics: Tx OAM Information PDU's
1.3.6.1.4.1.4756.20.501.20.1.612ColumnnidPort8TxUniqueErrorEventRemoteAread-onlycurrentNID Series card Port8 Detailed Link OAM Statistics: Tx Unique Error Event Notificatio
1.3.6.1.4.1.4756.20.501.20.1.613ColumnnidPort8TxDuplicateErrorEventRemoteAread-onlycurrentNID Series card Port8 Detailed Link OAM Statistics: Tx Duplicate Error Event Notification
1.3.6.1.4.1.4756.20.501.20.1.614ColumnnidPort8TxLoopBackControlRemoteAread-onlycurrentNID Series card Port8 Detailed Link OAM Statistics: Tx Loopback Control
1.3.6.1.4.1.4756.20.501.20.1.615ColumnnidPort8TxVariableRequestRemoteAread-onlycurrentNID Series card Port8 Detailed Link OAM Statistics: Tx Variable Request
1.3.6.1.4.1.4756.20.501.20.1.616ColumnnidPort8TxVariableResponseRemoteAread-onlycurrentNID Series card Port8 Detailed Link OAM Statistics: Tx Variable Response
1.3.6.1.4.1.4756.20.501.20.1.617ColumnnidPort8TxOrgSpecificPDURemoteAread-onlycurrentNID Series card Port8 Detailed Link OAM Statistics: Tx Org Specific PDU's
1.3.6.1.4.1.4756.20.501.20.1.618ColumnnidPort8TxUnsupportedCodesRemoteAread-onlycurrentNID Series card Port8 Detailed Link OAM Statistics: Tx Unsupported Codes
1.3.6.1.4.1.4756.20.501.20.1.619ColumnnidPort8TxLinkFaultPDURemoteAread-onlycurrentNID Series card Port8 Detailed Link OAM Statistics: Tx Link Fault PDU's
1.3.6.1.4.1.4756.20.501.20.1.620ColumnnidPort8TxDyingGaspRemoteAread-onlycurrentNID Series card Port8 Detailed Link OAM Statistics: Tx Dying Gasp
1.3.6.1.4.1.4756.20.501.20.1.621ColumnnidPort8TxCriticalEventPDURemoteAread-onlycurrentNID Series card Port8 Detailed Link OAM Statistics: Tx Dying Gasp
1.3.6.1.4.1.4756.20.501.20.1.622ColumnnidPort1PDUPermisionRemoteAread-onlycurrentNID Series card Detailed Link OAM Status for Port 1: PDU Permission
1.3.6.1.4.1.4756.20.501.20.1.623ColumnnidPort1DiscoveryStateRemoteAread-onlycurrentNID Series card Detailed Link OAM Status for Port 1: Discovery State
1.3.6.1.4.1.4756.20.501.20.1.624ColumnnidPort1PeerMACAddrRemoteAread-onlycurrentNID Series card Detailed Link OAM Status for Port 1: Discovery State
1.3.6.1.4.1.4756.20.501.20.1.625ColumnnidPort1RemoteAModeRemoteAread-onlycurrentNID Series card Detailed Link OAM Status for Port 1: RemoteA: Mode
1.3.6.1.4.1.4756.20.501.20.1.626ColumnnidPort1RemoteAUnOperationRemoteAread-onlycurrentNID Series card Detailed Link OAM Status for Port 1: RemoteA: Unidirectional Operation Support
1.3.6.1.4.1.4756.20.501.20.1.627ColumnnidPort1RemoteARemoteLbRemoteAread-onlycurrentNID Series card Detailed Link OAM Status for Port 1: RemoteA: Remote Loopback Support
1.3.6.1.4.1.4756.20.501.20.1.628ColumnnidPort1RemoteALMRemoteAread-onlycurrentNID Series card Detailed Link OAM Status for Port 1: RemoteA: Link Monitoring Support
1.3.6.1.4.1.4756.20.501.20.1.629ColumnnidPort1RemoteAMIBRetrievalRemoteAread-onlycurrentNID Series card Detailed Link OAM Status for Port 1: RemoteA: MIB Retrieval Support
1.3.6.1.4.1.4756.20.501.20.1.630ColumnnidPort1RemoteAMTUSizeRemoteAread-onlycurrentNID Series card Detailed Link OAM Status for Port 1: RemoteA: MTU Size
1.3.6.1.4.1.4756.20.501.20.1.631ColumnnidPort1RemoteAMultiStateRemoteAread-onlycurrentNID Series card Detailed Link OAM Status for Port 1: RemoteA: Multiplexer State
1.3.6.1.4.1.4756.20.501.20.1.632ColumnnidPort1RemoteAParserStateRemoteAread-onlycurrentNID Series card Detailed Link OAM Status for Port 1: RemoteA: Multiplexer State
1.3.6.1.4.1.4756.20.501.20.1.633ColumnnidPort1RemoteAOUIRemoteAread-onlycurrentNID Series card Detailed Link OAM Status for Port 1: RemoteA: Organizational Unique Identification
1.3.6.1.4.1.4756.20.501.20.1.634ColumnnidPort1RemoteAPDURevRemoteAread-onlycurrentNID Series card Detailed Link OAM Status for Port 1: RemoteA: PDU Revision
1.3.6.1.4.1.4756.20.501.20.1.635ColumnnidPort1PeerModeRemoteAread-onlycurrentNID Series card Detailed Link OAM Status for Port 1: Peer: Mode
1.3.6.1.4.1.4756.20.501.20.1.636ColumnnidPort1PeerUnOperationRemoteAread-onlycurrentNID Series card Detailed Link OAM Status for Port 1: Peer: Unidirectional Operation Support
1.3.6.1.4.1.4756.20.501.20.1.637ColumnnidPort1PeerRemoteLbRemoteAread-onlycurrentNID Series card Detailed Link OAM Status for Port 1: Peer: Remote Loopback Support
1.3.6.1.4.1.4756.20.501.20.1.638ColumnnidPort1PeerLMRemoteAread-onlycurrentNID Series card Detailed Link OAM Status for Port 1: Peer: Link Monitoring Support
1.3.6.1.4.1.4756.20.501.20.1.639ColumnnidPort1PeerMIBRetrievalRemoteAread-onlycurrentNID Series card Detailed Link OAM Status for Port 1: Peer: MIB Retrieval Support
1.3.6.1.4.1.4756.20.501.20.1.640ColumnnidPort1PeerMTUSizeRemoteAread-onlycurrentNID Series card Detailed Link OAM Status for Port 1: Peer: MTU Size
1.3.6.1.4.1.4756.20.501.20.1.641ColumnnidPort1PeerMultiStateRemoteAread-onlycurrentNID Series card Detailed Link OAM Status for Port 1: Peer: Multiplexer State
1.3.6.1.4.1.4756.20.501.20.1.642ColumnnidPort1PeerParserStateRemoteAread-onlycurrentNID Series card Detailed Link OAM Status for Port 1: Peer: Multiplexer State
1.3.6.1.4.1.4756.20.501.20.1.643ColumnnidPort1PeerOUIRemoteAread-onlycurrentNID Series card Detailed Link OAM Status for Port 1: Peer: Organizational Unique Identification
1.3.6.1.4.1.4756.20.501.20.1.644ColumnnidPort1PeerPDURevRemoteAread-onlycurrentNID Series card Detailed Link OAM Status for Port 1: Peer: PDU Revision
1.3.6.1.4.1.4756.20.501.20.1.645ColumnnidPort2PDUPermisionRemoteAread-onlycurrentNID Series card Detailed Link OAM Status for Port 2: PDU Permission
1.3.6.1.4.1.4756.20.501.20.1.646ColumnnidPort2DiscoveryStateRemoteAread-onlycurrentNID Series card Detailed Link OAM Status for Port 2: Discovery State
1.3.6.1.4.1.4756.20.501.20.1.647ColumnnidPort2PeerMACAddrRemoteAread-onlycurrentNID Series card Detailed Link OAM Status for Port 2: Discovery State
1.3.6.1.4.1.4756.20.501.20.1.648ColumnnidPort2RemoteAModeRemoteAread-onlycurrentNID Series card Detailed Link OAM Status for Port 2: RemoteA: Mode
1.3.6.1.4.1.4756.20.501.20.1.649ColumnnidPort2RemoteAUnOperationRemoteAread-onlycurrentNID Series card Detailed Link OAM Status for Port 2: RemoteA: Unidirectional Operation Support
1.3.6.1.4.1.4756.20.501.20.1.650ColumnnidPort2RemoteARemoteLbRemoteAread-onlycurrentNID Series card Detailed Link OAM Status for Port 2: RemoteA: Remote Loopback Support
1.3.6.1.4.1.4756.20.501.20.1.651ColumnnidPort2RemoteALMRemoteAread-onlycurrentNID Series card Detailed Link OAM Status for Port 2: RemoteA: Link Monitoring Support
1.3.6.1.4.1.4756.20.501.20.1.652ColumnnidPort2RemoteAMIBRetrievalRemoteAread-onlycurrentNID Series card Detailed Link OAM Status for Port 2: RemoteA: MIB Retrieval Support
1.3.6.1.4.1.4756.20.501.20.1.653ColumnnidPort2RemoteAMTUSizeRemoteAread-onlycurrentNID Series card Detailed Link OAM Status for Port 2: RemoteA: MTU Size
1.3.6.1.4.1.4756.20.501.20.1.654ColumnnidPort2RemoteAMultiStateRemoteAread-onlycurrentNID Series card Detailed Link OAM Status for Port 2: RemoteA: Multiplexer State
1.3.6.1.4.1.4756.20.501.20.1.655ColumnnidPort2RemoteAParserStateRemoteAread-onlycurrentNID Series card Detailed Link OAM Status for Port 2: RemoteA: Multiplexer State
1.3.6.1.4.1.4756.20.501.20.1.656ColumnnidPort2RemoteAOUIRemoteAread-onlycurrentNID Series card Detailed Link OAM Status for Port 2: RemoteA: Organizational Unique Identification
1.3.6.1.4.1.4756.20.501.20.1.657ColumnnidPort2RemoteAPDURevRemoteAread-onlycurrentNID Series card Detailed Link OAM Status for Port 2: RemoteA: PDU Revision
1.3.6.1.4.1.4756.20.501.20.1.658ColumnnidPort2PeerModeRemoteAread-onlycurrentNID Series card Detailed Link OAM Status for Port 2: Peer: Mode
1.3.6.1.4.1.4756.20.501.20.1.659ColumnnidPort2PeerUnOperationRemoteAread-onlycurrentNID Series card Detailed Link OAM Status for Port 2: Peer: Unidirectional Operation Support
1.3.6.1.4.1.4756.20.501.20.1.660ColumnnidPort2PeerRemoteLbRemoteAread-onlycurrentNID Series card Detailed Link OAM Status for Port 2: Peer: Remote Loopback Support
1.3.6.1.4.1.4756.20.501.20.1.661ColumnnidPort2PeerLMRemoteAread-onlycurrentNID Series card Detailed Link OAM Status for Port 2: Peer: Link Monitoring Support
1.3.6.1.4.1.4756.20.501.20.1.662ColumnnidPort2PeerMIBRetrievalRemoteAread-onlycurrentNID Series card Detailed Link OAM Status for Port 2: Peer: MIB Retrieval Support
1.3.6.1.4.1.4756.20.501.20.1.663ColumnnidPort2PeerMTUSizeRemoteAread-onlycurrentNID Series card Detailed Link OAM Status for Port 2: Peer: MTU Size
1.3.6.1.4.1.4756.20.501.20.1.664ColumnnidPort2PeerMultiStateRemoteAread-onlycurrentNID Series card Detailed Link OAM Status for Port 2: Peer: Multiplexer State
1.3.6.1.4.1.4756.20.501.20.1.665ColumnnidPort2PeerParserStateRemoteAread-onlycurrentNID Series card Detailed Link OAM Status for Port 2: Peer: Multiplexer State
1.3.6.1.4.1.4756.20.501.20.1.666ColumnnidPort2PeerOUIRemoteAread-onlycurrentNID Series card Detailed Link OAM Status for Port 2: Peer: Organizational Unique Identification
1.3.6.1.4.1.4756.20.501.20.1.667ColumnnidPort2PeerPDURevRemoteAread-onlycurrentNID Series card Detailed Link OAM Status for Port 2: Peer: PDU Revision
1.3.6.1.4.1.4756.20.501.20.1.668ColumnnidPort3PDUPermisionRemoteAread-onlycurrentNID Series card Detailed Link OAM Status for Port 3: PDU Permission
1.3.6.1.4.1.4756.20.501.20.1.669ColumnnidPort3DiscoveryStateRemoteAread-onlycurrentNID Series card Detailed Link OAM Status for Port 3: Discovery State
1.3.6.1.4.1.4756.20.501.20.1.670ColumnnidPort3PeerMACAddrRemoteAread-onlycurrentNID Series card Detailed Link OAM Status for Port 3: Discovery State
1.3.6.1.4.1.4756.20.501.20.1.671ColumnnidPort3RemoteAModeRemoteAread-onlycurrentNID Series card Detailed Link OAM Status for Port 3: RemoteA: Mode
1.3.6.1.4.1.4756.20.501.20.1.672ColumnnidPort3RemoteAUnOperationRemoteAread-onlycurrentNID Series card Detailed Link OAM Status for Port 3: RemoteA: Unidirectional Operation Support
1.3.6.1.4.1.4756.20.501.20.1.673ColumnnidPort3RemoteARemoteLbRemoteAread-onlycurrentNID Series card Detailed Link OAM Status for Port 3: RemoteA: Remote Loopback Support
1.3.6.1.4.1.4756.20.501.20.1.674ColumnnidPort3RemoteALMRemoteAread-onlycurrentNID Series card Detailed Link OAM Status for Port 3: RemoteA: Link Monitoring Support
1.3.6.1.4.1.4756.20.501.20.1.675ColumnnidPort3RemoteAMIBRetrievalRemoteAread-onlycurrentNID Series card Detailed Link OAM Status for Port 3: RemoteA: MIB Retrieval Support
1.3.6.1.4.1.4756.20.501.20.1.676ColumnnidPort3RemoteAMTUSizeRemoteAread-onlycurrentNID Series card Detailed Link OAM Status for Port 3: RemoteA: MTU Size
1.3.6.1.4.1.4756.20.501.20.1.677ColumnnidPort3RemoteAMultiStateRemoteAread-onlycurrentNID Series card Detailed Link OAM Status for Port 3: RemoteA: Multiplexer State
1.3.6.1.4.1.4756.20.501.20.1.678ColumnnidPort3RemoteAParserStateRemoteAread-onlycurrentNID Series card Detailed Link OAM Status for Port 3: RemoteA: Multiplexer State
1.3.6.1.4.1.4756.20.501.20.1.679ColumnnidPort3RemoteAOUIRemoteAread-onlycurrentNID Series card Detailed Link OAM Status for Port 3: RemoteA: Organizational Unique Identification
1.3.6.1.4.1.4756.20.501.20.1.680ColumnnidPort3RemoteAPDURevRemoteAread-onlycurrentNID Series card Detailed Link OAM Status for Port 3: RemoteA: PDU Revision
1.3.6.1.4.1.4756.20.501.20.1.681ColumnnidPort3PeerModeRemoteAread-onlycurrentNID Series card Detailed Link OAM Status for Port 3: Peer: Mode
1.3.6.1.4.1.4756.20.501.20.1.682ColumnnidPort3PeerUnOperationRemoteAread-onlycurrentNID Series card Detailed Link OAM Status for Port 3: Peer: Unidirectional Operation Support
1.3.6.1.4.1.4756.20.501.20.1.683ColumnnidPort3PeerRemoteLbRemoteAread-onlycurrentNID Series card Detailed Link OAM Status for Port 3: Peer: Remote Loopback Support
1.3.6.1.4.1.4756.20.501.20.1.684ColumnnidPort3PeerLMRemoteAread-onlycurrentNID Series card Detailed Link OAM Status for Port 3: Peer: Link Monitoring Support
1.3.6.1.4.1.4756.20.501.20.1.685ColumnnidPort3PeerMIBRetrievalRemoteAread-onlycurrentNID Series card Detailed Link OAM Status for Port 3: Peer: MIB Retrieval Support
1.3.6.1.4.1.4756.20.501.20.1.686ColumnnidPort3PeerMTUSizeRemoteAread-onlycurrentNID Series card Detailed Link OAM Status for Port 3: Peer: MTU Size
1.3.6.1.4.1.4756.20.501.20.1.687ColumnnidPort3PeerMultiStateRemoteAread-onlycurrentNID Series card Detailed Link OAM Status for Port 3: Peer: Multiplexer State
1.3.6.1.4.1.4756.20.501.20.1.688ColumnnidPort3PeerParserStateRemoteAread-onlycurrentNID Series card Detailed Link OAM Status for Port 3: Peer: Multiplexer State
1.3.6.1.4.1.4756.20.501.20.1.689ColumnnidPort3PeerOUIRemoteAread-onlycurrentNID Series card Detailed Link OAM Status for Port 3: Peer: Organizational Unique Identification
1.3.6.1.4.1.4756.20.501.20.1.690ColumnnidPort3PeerPDURevRemoteAread-onlycurrentNID Series card Detailed Link OAM Status for Port 3: Peer: PDU Revision
1.3.6.1.4.1.4756.20.501.20.1.691ColumnnidPort4PDUPermisionRemoteAread-onlycurrentNID Series card Detailed Link OAM Status for Port 4: PDU Permission
1.3.6.1.4.1.4756.20.501.20.1.692ColumnnidPort4DiscoveryStateRemoteAread-onlycurrentNID Series card Detailed Link OAM Status for Port 4: Discovery State
1.3.6.1.4.1.4756.20.501.20.1.693ColumnnidPort4PeerMACAddrRemoteAread-onlycurrentNID Series card Detailed Link OAM Status for Port 4: Discovery State
1.3.6.1.4.1.4756.20.501.20.1.694ColumnnidPort4RemoteAModeRemoteAread-onlycurrentNID Series card Detailed Link OAM Status for Port 4: RemoteA: Mode
1.3.6.1.4.1.4756.20.501.20.1.695ColumnnidPort4RemoteAUnOperationRemoteAread-onlycurrentNID Series card Detailed Link OAM Status for Port 4: RemoteA: Unidirectional Operation Support
1.3.6.1.4.1.4756.20.501.20.1.696ColumnnidPort4RemoteARemoteLbRemoteAread-onlycurrentNID Series card Detailed Link OAM Status for Port 4: RemoteA: Remote Loopback Support
1.3.6.1.4.1.4756.20.501.20.1.697ColumnnidPort4RemoteALMRemoteAread-onlycurrentNID Series card Detailed Link OAM Status for Port 4: RemoteA: Link Monitoring Support
1.3.6.1.4.1.4756.20.501.20.1.698ColumnnidPort4RemoteAMIBRetrievalRemoteAread-onlycurrentNID Series card Detailed Link OAM Status for Port 4: RemoteA: MIB Retrieval Support
1.3.6.1.4.1.4756.20.501.20.1.699ColumnnidPort4RemoteAMTUSizeRemoteAread-onlycurrentNID Series card Detailed Link OAM Status for Port 4: RemoteA: MTU Size
1.3.6.1.4.1.4756.20.501.20.1.700ColumnnidPort4RemoteAMultiStateRemoteAread-onlycurrentNID Series card Detailed Link OAM Status for Port 4: RemoteA: Multiplexer State
1.3.6.1.4.1.4756.20.501.20.1.701ColumnnidPort4RemoteAParserStateRemoteAread-onlycurrentNID Series card Detailed Link OAM Status for Port 4: RemoteA: Multiplexer State
1.3.6.1.4.1.4756.20.501.20.1.702ColumnnidPort4RemoteAOUIRemoteAread-onlycurrentNID Series card Detailed Link OAM Status for Port 4: RemoteA: Organizational Unique Identification
1.3.6.1.4.1.4756.20.501.20.1.703ColumnnidPort4RemoteAPDURevRemoteAread-onlycurrentNID Series card Detailed Link OAM Status for Port 4: RemoteA: PDU Revision
1.3.6.1.4.1.4756.20.501.20.1.704ColumnnidPort4PeerModeRemoteAread-onlycurrentNID Series card Detailed Link OAM Status for Port 4: Peer: Mode
1.3.6.1.4.1.4756.20.501.20.1.705ColumnnidPort4PeerUnOperationRemoteAread-onlycurrentNID Series card Detailed Link OAM Status for Port 4: Peer: Unidirectional Operation Support
1.3.6.1.4.1.4756.20.501.20.1.706ColumnnidPort4PeerRemoteLbRemoteAread-onlycurrentNID Series card Detailed Link OAM Status for Port 4: Peer: Remote Loopback Support
1.3.6.1.4.1.4756.20.501.20.1.707ColumnnidPort4PeerLMRemoteAread-onlycurrentNID Series card Detailed Link OAM Status for Port 4: Peer: Link Monitoring Support
1.3.6.1.4.1.4756.20.501.20.1.708ColumnnidPort4PeerMIBRetrievalRemoteAread-onlycurrentNID Series card Detailed Link OAM Status for Port 4: Peer: MIB Retrieval Support
1.3.6.1.4.1.4756.20.501.20.1.709ColumnnidPort4PeerMTUSizeRemoteAread-onlycurrentNID Series card Detailed Link OAM Status for Port 4: Peer: MTU Size
1.3.6.1.4.1.4756.20.501.20.1.710ColumnnidPort4PeerMultiStateRemoteAread-onlycurrentNID Series card Detailed Link OAM Status for Port 4: Peer: Multiplexer State
1.3.6.1.4.1.4756.20.501.20.1.711ColumnnidPort4PeerParserStateRemoteAread-onlycurrentNID Series card Detailed Link OAM Status for Port 4: Peer: Multiplexer State
1.3.6.1.4.1.4756.20.501.20.1.712ColumnnidPort4PeerOUIRemoteAread-onlycurrentNID Series card Detailed Link OAM Status for Port 4: Peer: Organizational Unique Identification
1.3.6.1.4.1.4756.20.501.20.1.713ColumnnidPort4PeerPDURevRemoteAread-onlycurrentNID Series card Detailed Link OAM Status for Port 4: Peer: PDU Revision
1.3.6.1.4.1.4756.20.501.20.1.714ColumnnidPort5PDUPermisionRemoteAread-onlycurrentNID Series card Detailed Link OAM Status for Port 5: PDU Permission
1.3.6.1.4.1.4756.20.501.20.1.715ColumnnidPort5DiscoveryStateRemoteAread-onlycurrentNID Series card Detailed Link OAM Status for Port 5: Discovery State
1.3.6.1.4.1.4756.20.501.20.1.716ColumnnidPort5PeerMACAddrRemoteAread-onlycurrentNID Series card Detailed Link OAM Status for Port 5: Discovery State
1.3.6.1.4.1.4756.20.501.20.1.717ColumnnidPort5RemoteAModeRemoteAread-onlycurrentNID Series card Detailed Link OAM Status for Port 5: RemoteA: Mode
1.3.6.1.4.1.4756.20.501.20.1.718ColumnnidPort5RemoteAUnOperationRemoteAread-onlycurrentNID Series card Detailed Link OAM Status for Port 5: RemoteA: Unidirectional Operation Support
1.3.6.1.4.1.4756.20.501.20.1.719ColumnnidPort5RemoteARemoteLbRemoteAread-onlycurrentNID Series card Detailed Link OAM Status for Port 5: RemoteA: Remote Loopback Support
1.3.6.1.4.1.4756.20.501.20.1.720ColumnnidPort5RemoteALMRemoteAread-onlycurrentNID Series card Detailed Link OAM Status for Port 5: RemoteA: Link Monitoring Support
1.3.6.1.4.1.4756.20.501.20.1.721ColumnnidPort5RemoteAMIBRetrievalRemoteAread-onlycurrentNID Series card Detailed Link OAM Status for Port 5: RemoteA: MIB Retrieval Support
1.3.6.1.4.1.4756.20.501.20.1.722ColumnnidPort5RemoteAMTUSizeRemoteAread-onlycurrentNID Series card Detailed Link OAM Status for Port 5: RemoteA: MTU Size
1.3.6.1.4.1.4756.20.501.20.1.723ColumnnidPort5RemoteAMultiStateRemoteAread-onlycurrentNID Series card Detailed Link OAM Status for Port 5: RemoteA: Multiplexer State
1.3.6.1.4.1.4756.20.501.20.1.724ColumnnidPort5RemoteAParserStateRemoteAread-onlycurrentNID Series card Detailed Link OAM Status for Port 5: RemoteA: Multiplexer State
1.3.6.1.4.1.4756.20.501.20.1.725ColumnnidPort5RemoteAOUIRemoteAread-onlycurrentNID Series card Detailed Link OAM Status for Port 5: RemoteA: Organizational Unique Identification
1.3.6.1.4.1.4756.20.501.20.1.726ColumnnidPort5RemoteAPDURevRemoteAread-onlycurrentNID Series card Detailed Link OAM Status for Port 5: RemoteA: PDU Revision
1.3.6.1.4.1.4756.20.501.20.1.727ColumnnidPort5PeerModeRemoteAread-onlycurrentNID Series card Detailed Link OAM Status for Port 5: Peer: Mode
1.3.6.1.4.1.4756.20.501.20.1.728ColumnnidPort5PeerUnOperationRemoteAread-onlycurrentNID Series card Detailed Link OAM Status for Port 5: Peer: Unidirectional Operation Support
1.3.6.1.4.1.4756.20.501.20.1.729ColumnnidPort5PeerRemoteLbRemoteAread-onlycurrentNID Series card Detailed Link OAM Status for Port 5: Peer: Remote Loopback Support
1.3.6.1.4.1.4756.20.501.20.1.730ColumnnidPort5PeerLMRemoteAread-onlycurrentNID Series card Detailed Link OAM Status for Port 5: Peer: Link Monitoring Support
1.3.6.1.4.1.4756.20.501.20.1.731ColumnnidPort5PeerMIBRetrievalRemoteAread-onlycurrentNID Series card Detailed Link OAM Status for Port 5: Peer: MIB Retrieval Support
1.3.6.1.4.1.4756.20.501.20.1.732ColumnnidPort5PeerMTUSizeRemoteAread-onlycurrentNID Series card Detailed Link OAM Status for Port 5: Peer: MTU Size
1.3.6.1.4.1.4756.20.501.20.1.733ColumnnidPort5PeerMultiStateRemoteAread-onlycurrentNID Series card Detailed Link OAM Status for Port 5: Peer: Multiplexer State
1.3.6.1.4.1.4756.20.501.20.1.734ColumnnidPort5PeerParserStateRemoteAread-onlycurrentNID Series card Detailed Link OAM Status for Port 5: Peer: Multiplexer State
1.3.6.1.4.1.4756.20.501.20.1.735ColumnnidPort5PeerOUIRemoteAread-onlycurrentNID Series card Detailed Link OAM Status for Port 5: Peer: Organizational Unique Identification
1.3.6.1.4.1.4756.20.501.20.1.736ColumnnidPort5PeerPDURevRemoteAread-onlycurrentNID Series card Detailed Link OAM Status for Port 5: Peer: PDU Revision
1.3.6.1.4.1.4756.20.501.20.1.737ColumnnidPort6PDUPermisionRemoteAread-onlycurrentNID Series card Detailed Link OAM Status for Port 6: PDU Permission
1.3.6.1.4.1.4756.20.501.20.1.738ColumnnidPort6DiscoveryStateRemoteAread-onlycurrentNID Series card Detailed Link OAM Status for Port 6: Discovery State
1.3.6.1.4.1.4756.20.501.20.1.739ColumnnidPort6PeerMACAddrRemoteAread-onlycurrentNID Series card Detailed Link OAM Status for Port 6: Discovery State
1.3.6.1.4.1.4756.20.501.20.1.740ColumnnidPort6RemoteAModeRemoteAread-onlycurrentNID Series card Detailed Link OAM Status for Port 6: RemoteA: Mode
1.3.6.1.4.1.4756.20.501.20.1.741ColumnnidPort6RemoteAUnOperationRemoteAread-onlycurrentNID Series card Detailed Link OAM Status for Port 6: RemoteA: Unidirectional Operation Support
1.3.6.1.4.1.4756.20.501.20.1.742ColumnnidPort6RemoteARemoteLbRemoteAread-onlycurrentNID Series card Detailed Link OAM Status for Port 6: RemoteA: Remote Loopback Support
1.3.6.1.4.1.4756.20.501.20.1.743ColumnnidPort6RemoteALMRemoteAread-onlycurrentNID Series card Detailed Link OAM Status for Port 6: RemoteA: Link Monitoring Support
1.3.6.1.4.1.4756.20.501.20.1.744ColumnnidPort6RemoteAMIBRetrievalRemoteAread-onlycurrentNID Series card Detailed Link OAM Status for Port 6: RemoteA: MIB Retrieval Support
1.3.6.1.4.1.4756.20.501.20.1.745ColumnnidPort6RemoteAMTUSizeRemoteAread-onlycurrentNID Series card Detailed Link OAM Status for Port 6: RemoteA: MTU Size
1.3.6.1.4.1.4756.20.501.20.1.746ColumnnidPort6RemoteAMultiStateRemoteAread-onlycurrentNID Series card Detailed Link OAM Status for Port 6: RemoteA: Multiplexer State
1.3.6.1.4.1.4756.20.501.20.1.747ColumnnidPort6RemoteAParserStateRemoteAread-onlycurrentNID Series card Detailed Link OAM Status for Port 6: RemoteA: Multiplexer State
1.3.6.1.4.1.4756.20.501.20.1.748ColumnnidPort6RemoteAOUIRemoteAread-onlycurrentNID Series card Detailed Link OAM Status for Port 6: RemoteA: Organizational Unique Identification
1.3.6.1.4.1.4756.20.501.20.1.749ColumnnidPort6RemoteAPDURevRemoteAread-onlycurrentNID Series card Detailed Link OAM Status for Port 6: RemoteA: PDU Revision
1.3.6.1.4.1.4756.20.501.20.1.750ColumnnidPort6PeerModeRemoteAread-onlycurrentNID Series card Detailed Link OAM Status for Port 6: Peer: Mode
1.3.6.1.4.1.4756.20.501.20.1.751ColumnnidPort6PeerUnOperationRemoteAread-onlycurrentNID Series card Detailed Link OAM Status for Port 6: Peer: Unidirectional Operation Support
1.3.6.1.4.1.4756.20.501.20.1.752ColumnnidPort6PeerRemoteLbRemoteAread-onlycurrentNID Series card Detailed Link OAM Status for Port 6: Peer: Remote Loopback Support
1.3.6.1.4.1.4756.20.501.20.1.753ColumnnidPort6PeerLMRemoteAread-onlycurrentNID Series card Detailed Link OAM Status for Port 6: Peer: Link Monitoring Support
1.3.6.1.4.1.4756.20.501.20.1.754ColumnnidPort6PeerMIBRetrievalRemoteAread-onlycurrentNID Series card Detailed Link OAM Status for Port 6: Peer: MIB Retrieval Support
1.3.6.1.4.1.4756.20.501.20.1.755ColumnnidPort6PeerMTUSizeRemoteAread-onlycurrentNID Series card Detailed Link OAM Status for Port 6: Peer: MTU Size
1.3.6.1.4.1.4756.20.501.20.1.756ColumnnidPort6PeerMultiStateRemoteAread-onlycurrentNID Series card Detailed Link OAM Status for Port 6: Peer: Multiplexer State
1.3.6.1.4.1.4756.20.501.20.1.757ColumnnidPort6PeerParserStateRemoteAread-onlycurrentNID Series card Detailed Link OAM Status for Port 6: Peer: Multiplexer State
1.3.6.1.4.1.4756.20.501.20.1.758ColumnnidPort6PeerOUIRemoteAread-onlycurrentNID Series card Detailed Link OAM Status for Port 6: Peer: Organizational Unique Identification
1.3.6.1.4.1.4756.20.501.20.1.759ColumnnidPort6PeerPDURevRemoteAread-onlycurrentNID Series card Detailed Link OAM Status for Port 6: Peer: PDU Revision
1.3.6.1.4.1.4756.20.501.20.1.760ColumnnidPort7PDUPermisionRemoteAread-onlycurrentNID Series card Detailed Link OAM Status for Port 7: PDU Permission
1.3.6.1.4.1.4756.20.501.20.1.761ColumnnidPort7DiscoveryStateRemoteAread-onlycurrentNID Series card Detailed Link OAM Status for Port 7: Discovery State
1.3.6.1.4.1.4756.20.501.20.1.762ColumnnidPort7PeerMACAddrRemoteAread-onlycurrentNID Series card Detailed Link OAM Status for Port 7: Discovery State
1.3.6.1.4.1.4756.20.501.20.1.763ColumnnidPort7RemoteAModeRemoteAread-onlycurrentNID Series card Detailed Link OAM Status for Port 7: RemoteA: Mode
1.3.6.1.4.1.4756.20.501.20.1.764ColumnnidPort7RemoteAUnOperationRemoteAread-onlycurrentNID Series card Detailed Link OAM Status for Port 7: RemoteA: Unidirectional Operation Support
1.3.6.1.4.1.4756.20.501.20.1.765ColumnnidPort7RemoteARemoteLbRemoteAread-onlycurrentNID Series card Detailed Link OAM Status for Port 7: RemoteA: Remote Loopback Support
1.3.6.1.4.1.4756.20.501.20.1.766ColumnnidPort7RemoteALMRemoteAread-onlycurrentNID Series card Detailed Link OAM Status for Port 7: RemoteA: Link Monitoring Support
1.3.6.1.4.1.4756.20.501.20.1.767ColumnnidPort7RemoteAMIBRetrievalRemoteAread-onlycurrentNID Series card Detailed Link OAM Status for Port 7: RemoteA: MIB Retrieval Support
1.3.6.1.4.1.4756.20.501.20.1.768ColumnnidPort7RemoteAMTUSizeRemoteAread-onlycurrentNID Series card Detailed Link OAM Status for Port 7: RemoteA: MTU Size
1.3.6.1.4.1.4756.20.501.20.1.769ColumnnidPort7RemoteAMultiStateRemoteAread-onlycurrentNID Series card Detailed Link OAM Status for Port 7: RemoteA: Multiplexer State
1.3.6.1.4.1.4756.20.501.20.1.770ColumnnidPort7RemoteAParserStateRemoteAread-onlycurrentNID Series card Detailed Link OAM Status for Port 7: RemoteA: Multiplexer State
1.3.6.1.4.1.4756.20.501.20.1.771ColumnnidPort7RemoteAOUIRemoteAread-onlycurrentNID Series card Detailed Link OAM Status for Port 7: RemoteA: Organizational Unique Identification
1.3.6.1.4.1.4756.20.501.20.1.772ColumnnidPort7RemoteAPDURevRemoteAread-onlycurrentNID Series card Detailed Link OAM Status for Port 7: RemoteA: PDU Revision
1.3.6.1.4.1.4756.20.501.20.1.773ColumnnidPort7PeerModeRemoteAread-onlycurrentNID Series card Detailed Link OAM Status for Port 7: Peer: Mode
1.3.6.1.4.1.4756.20.501.20.1.774ColumnnidPort7PeerUnOperationRemoteAread-onlycurrentNID Series card Detailed Link OAM Status for Port 7: Peer: Unidirectional Operation Support
1.3.6.1.4.1.4756.20.501.20.1.775ColumnnidPort7PeerRemoteLbRemoteAread-onlycurrentNID Series card Detailed Link OAM Status for Port 7: Peer: Remote Loopback Support
1.3.6.1.4.1.4756.20.501.20.1.776ColumnnidPort7PeerLMRemoteAread-onlycurrentNID Series card Detailed Link OAM Status for Port 7: Peer: Link Monitoring Support
1.3.6.1.4.1.4756.20.501.20.1.777ColumnnidPort7PeerMIBRetrievalRemoteAread-onlycurrentNID Series card Detailed Link OAM Status for Port 7: Peer: MIB Retrieval Support
1.3.6.1.4.1.4756.20.501.20.1.778ColumnnidPort7PeerMTUSizeRemoteAread-onlycurrentNID Series card Detailed Link OAM Status for Port 7: Peer: MTU Size
1.3.6.1.4.1.4756.20.501.20.1.779ColumnnidPort7PeerMultiStateRemoteAread-onlycurrentNID Series card Detailed Link OAM Status for Port 7: Peer: Multiplexer State
1.3.6.1.4.1.4756.20.501.20.1.780ColumnnidPort7PeerParserStateRemoteAread-onlycurrentNID Series card Detailed Link OAM Status for Port 7: Peer: Multiplexer State
1.3.6.1.4.1.4756.20.501.20.1.781ColumnnidPort7PeerOUIRemoteAread-onlycurrentNID Series card Detailed Link OAM Status for Port 7: Peer: Organizational Unique Identification
1.3.6.1.4.1.4756.20.501.20.1.782ColumnnidPort7PeerPDURevRemoteAread-onlycurrentNID Series card Detailed Link OAM Status for Port 7: Peer: PDU Revision
1.3.6.1.4.1.4756.20.501.20.1.783ColumnnidPort8PDUPermisionRemoteAread-onlycurrentNID Series card Detailed Link OAM Status for Port 8: PDU Permission
1.3.6.1.4.1.4756.20.501.20.1.784ColumnnidPort8DiscoveryStateRemoteAread-onlycurrentNID Series card Detailed Link OAM Status for Port 8: Discovery State
1.3.6.1.4.1.4756.20.501.20.1.785ColumnnidPort8PeerMACAddrRemoteAread-onlycurrentNID Series card Detailed Link OAM Status for Port 8: Discovery State
1.3.6.1.4.1.4756.20.501.20.1.786ColumnnidPort8RemoteAModeRemoteAread-onlycurrentNID Series card Detailed Link OAM Status for Port 8: RemoteA: Mode
1.3.6.1.4.1.4756.20.501.20.1.787ColumnnidPort8RemoteAUnOperationRemoteAread-onlycurrentNID Series card Detailed Link OAM Status for Port 8: RemoteA: Unidirectional Operation Support
1.3.6.1.4.1.4756.20.501.20.1.788ColumnnidPort8RemoteARemoteLbRemoteAread-onlycurrentNID Series card Detailed Link OAM Status for Port 8: RemoteA: Remote Loopback Support
1.3.6.1.4.1.4756.20.501.20.1.789ColumnnidPort8RemoteALMRemoteAread-onlycurrentNID Series card Detailed Link OAM Status for Port 8: RemoteA: Link Monitoring Support
1.3.6.1.4.1.4756.20.501.20.1.790ColumnnidPort8RemoteAMIBRetrievalRemoteAread-onlycurrentNID Series card Detailed Link OAM Status for Port 8: RemoteA: MIB Retrieval Support
1.3.6.1.4.1.4756.20.501.20.1.791ColumnnidPort8RemoteAMTUSizeRemoteAread-onlycurrentNID Series card Detailed Link OAM Status for Port 8: RemoteA: MTU Size
1.3.6.1.4.1.4756.20.501.20.1.792ColumnnidPort8RemoteAMultiStateRemoteAread-onlycurrentNID Series card Detailed Link OAM Status for Port 8: RemoteA: Multiplexer State
1.3.6.1.4.1.4756.20.501.20.1.793ColumnnidPort8RemoteAParserStateRemoteAread-onlycurrentNID Series card Detailed Link OAM Status for Port 8: RemoteA: Multiplexer State
1.3.6.1.4.1.4756.20.501.20.1.794ColumnnidPort8RemoteAOUIRemoteAread-onlycurrentNID Series card Detailed Link OAM Status for Port 8: RemoteA: Organizational Unique Identification
1.3.6.1.4.1.4756.20.501.20.1.795ColumnnidPort8RemoteAPDURevRemoteAread-onlycurrentNID Series card Detailed Link OAM Status for Port 8: RemoteA: PDU Revision
1.3.6.1.4.1.4756.20.501.20.1.796ColumnnidPort8PeerModeRemoteAread-onlycurrentNID Series card Detailed Link OAM Status for Port 8: Peer: Mode
1.3.6.1.4.1.4756.20.501.20.1.797ColumnnidPort8PeerUnOperationRemoteAread-onlycurrentNID Series card Detailed Link OAM Status for Port 8: Peer: Unidirectional Operation Support
1.3.6.1.4.1.4756.20.501.20.1.798ColumnnidPort8PeerRemoteLbRemoteAread-onlycurrentNID Series card Detailed Link OAM Status for Port 8: Peer: Remote Loopback Support
1.3.6.1.4.1.4756.20.501.20.1.799ColumnnidPort8PeerLMRemoteAread-onlycurrentNID Series card Detailed Link OAM Status for Port 8: Peer: Link Monitoring Support
1.3.6.1.4.1.4756.20.501.20.1.800ColumnnidPort8PeerMIBRetrievalRemoteAread-onlycurrentNID Series card Detailed Link OAM Status for Port 8: Peer: MIB Retrieval Support
1.3.6.1.4.1.4756.20.501.20.1.801ColumnnidPort8PeerMTUSizeRemoteAread-onlycurrentNID Series card Detailed Link OAM Status for Port 8: Peer: MTU Size
1.3.6.1.4.1.4756.20.501.20.1.802ColumnnidPort8PeerMultiStateRemoteAread-onlycurrentNID Series card Detailed Link OAM Status for Port 8: Peer: Multiplexer State
1.3.6.1.4.1.4756.20.501.20.1.803ColumnnidPort8PeerParserStateRemoteAread-onlycurrentNID Series card Detailed Link OAM Status for Port 8: Peer: Multiplexer State
1.3.6.1.4.1.4756.20.501.20.1.804ColumnnidPort8PeerOUIRemoteAread-onlycurrentNID Series card Detailed Link OAM Status for Port 8: Peer: Organizational Unique Identification
1.3.6.1.4.1.4756.20.501.20.1.805ColumnnidPort8PeerPDURevRemoteAread-onlycurrentNID Series card Detailed Link OAM Status for Port 8: Peer: PDU Revision
1.3.6.1.4.1.4756.20.501.20.1.806ColumnnidLoopProtectionEnableRemoteAread-writecurrentNID Series card Loop Protection Configuration: General Settings - Enable Loop Protection 0: Disable 1: Enable
1.3.6.1.4.1.4756.20.501.20.1.807ColumnnidLoopProtectionTxTimeRemoteAread-writecurrentNID Series card Loop Protection Configuration: General Settings - Transmission Time
1.3.6.1.4.1.4756.20.501.20.1.808ColumnnidLoopProtectionShutdownTimeRemoteAread-writecurrentNID Series card Loop Protection Configuration: General Settings - Shutdown Time
1.3.6.1.4.1.4756.20.501.20.1.809ColumnnidLoopProtectionPort1EnabledRemoteAread-writecurrentNID Series card Loop Protection Configuration for Port 1: Port Configuration - Enable 0: Disable 1: Enable
1.3.6.1.4.1.4756.20.501.20.1.810ColumnnidLoopProtectionPort1ActionRemoteAread-writecurrentNID Series card Loop Protection Configuration for Port 1: Port Configuration - Action 0: Shutdown Port 1: Shutdown Port And Log 2: Log Only
1.3.6.1.4.1.4756.20.501.20.1.811ColumnnidLoopProtectionPort1TxModeRemoteAread-writecurrentNID Series card Loop Protection Configuration for Port 1: Port Configuration - Tx Mode 0: Disable 1: Enable
1.3.6.1.4.1.4756.20.501.20.1.812ColumnnidLoopProtectionPort2EnabledRemoteAread-writecurrentNID Series card Loop Protection Configuration for Port 2: Port Configuration - Enable 0: Disable 1: Enable
1.3.6.1.4.1.4756.20.501.20.1.813ColumnnidLoopProtectionPort2ActionRemoteAread-writecurrentNID Series card Loop Protection Configuration for Port 2: Port Configuration - Action 0: Shutdown Port 1: Shutdown Port And Log 2: Log Only
1.3.6.1.4.1.4756.20.501.20.1.814ColumnnidLoopProtectionPort2TxModeRemoteAread-writecurrentNID Series card Loop Protection Configuration for Port 2: Port Configuration - Tx Mode 0: Disable 1: Enable
1.3.6.1.4.1.4756.20.501.20.1.815ColumnnidLoopProtectionPort3EnabledRemoteAread-writecurrentNID Series card Loop Protection Configuration for Port 3: Port Configuration - Enable 0: Disable 1: Enable
1.3.6.1.4.1.4756.20.501.20.1.816ColumnnidLoopProtectionPort3ActionRemoteAread-writecurrentNID Series card Loop Protection Configuration for Port 3: Port Configuration - Action 0: Shutdown Port 1: Shutdown Port And Log 2: Log Only
1.3.6.1.4.1.4756.20.501.20.1.817ColumnnidLoopProtectionPort3TxModeRemoteAread-writecurrentNID Series card Loop Protection Configuration for Port 3: Port Configuration - Tx Mode 0: Disable 1: Enable
1.3.6.1.4.1.4756.20.501.20.1.818ColumnnidLoopProtectionPort4EnabledRemoteAread-writecurrentNID Series card Loop Protection Configuration for Port 4: Port Configuration - Enable 0: Disable 1: Enable
1.3.6.1.4.1.4756.20.501.20.1.819ColumnnidLoopProtectionPort4ActionRemoteAread-writecurrentNID Series card Loop Protection Configuration for Port 4: Port Configuration - Action 0: Shutdown Port 1: Shutdown Port And Log 2: Log Only
1.3.6.1.4.1.4756.20.501.20.1.820ColumnnidLoopProtectionPort4TxModeRemoteAread-writecurrentNID Series card Loop Protection Configuration for Port 41: Port Configuration - Tx Mode 0: Disable 1: Enable
1.3.6.1.4.1.4756.20.501.20.1.821ColumnnidLoopProtectionPort5EnabledRemoteAread-writecurrentNID Series card Loop Protection Configuration for Port 5: Port Configuration - Enable 0: Disable 1: Enable
1.3.6.1.4.1.4756.20.501.20.1.822ColumnnidLoopProtectionPort5ActionRemoteAread-writecurrentNID Series card Loop Protection Configuration for Port 5: Port Configuration - Action 0: Shutdown Port 1: Shutdown Port And Log 2: Log Only
1.3.6.1.4.1.4756.20.501.20.1.823ColumnnidLoopProtectionPort5TxModeRemoteAread-writecurrentNID Series card Loop Protection Configuration for Port 5: Port Configuration - Tx Mode 0: Disable 1: Enable
1.3.6.1.4.1.4756.20.501.20.1.824ColumnnidLoopProtectionPort6EnabledRemoteAread-writecurrentNID Series card Loop Protection Configuration for Port 6: Port Configuration - Enable 0: Disable 1: Enable
1.3.6.1.4.1.4756.20.501.20.1.825ColumnnidLoopProtectionPort6ActionRemoteAread-writecurrentNID Series card Loop Protection Configuration for Port 6: Port Configuration - Action 0: Shutdown Port 1: Shutdown Port And Log 2: Log Only
1.3.6.1.4.1.4756.20.501.20.1.826ColumnnidLoopProtectionPort6TxModeRemoteAread-writecurrentNID Series card Loop Protection Configuration for Port 6: Port Configuration - Tx Mode 0: Disable 1: Enable
1.3.6.1.4.1.4756.20.501.20.1.827ColumnnidLoopProtectionPort7EnabledRemoteAread-writecurrentNID Series card Loop Protection Configuration for Port 7: Port Configuration - Enable 0: Disable 1: Enable
1.3.6.1.4.1.4756.20.501.20.1.828ColumnnidLoopProtectionPort7ActionRemoteAread-writecurrentNID Series card Loop Protection Configuration for Port 7: Port Configuration - Action 0: Shutdown Port 1: Shutdown Port And Log 2: Log Only
1.3.6.1.4.1.4756.20.501.20.1.829ColumnnidLoopProtectionPort7TxModeRemoteAread-writecurrentNID Series card Loop Protection Configuration for Port 7: Port Configuration - Tx Mode 0: Disable 1: Enable
1.3.6.1.4.1.4756.20.501.20.1.830ColumnnidLoopProtectionPort8EnabledRemoteAread-writecurrentNID Series card Loop Protection Configuration for Port 8: Port Configuration - Enable 0: Disable 1: Enable
1.3.6.1.4.1.4756.20.501.20.1.831ColumnnidLoopProtectionPort8ActionRemoteAread-writecurrentNID Series card Loop Protection Configuration for Port 8: Port Configuration - Action 0: Shutdown Port 1: Shutdown Port And Log 2: Log Only
1.3.6.1.4.1.4756.20.501.20.1.832ColumnnidLoopProtectionPort8TxModeRemoteAread-writecurrentNID Series card Loop Protection Configuration for Port 8: Port Configuration - Tx Mode 0: Disable 1: Enable
1.3.6.1.4.1.4756.20.501.20.1.833ColumnnidLoopProtectionPort1ActionStsRemoteAread-onlycurrentNID Series card Loop Protection Status for Port 1: Action
1.3.6.1.4.1.4756.20.501.20.1.834ColumnnidLoopProtectionPort1TransStsRemoteAread-onlycurrentNID Series card Loop Protection Status for Port 1: Transmit
1.3.6.1.4.1.4756.20.501.20.1.835ColumnnidLoopProtectionPort1LoopsStsRemoteAread-onlycurrentNID Series card Loop Protection Status for Port 1: Loops
1.3.6.1.4.1.4756.20.501.20.1.836ColumnnidLoopProtectionPort1StatusRemoteAread-onlycurrentNID Series card Loop Protection Status for Port 1: Status
1.3.6.1.4.1.4756.20.501.20.1.837ColumnnidLoopProtectionPort1LoopStsRemoteAread-onlycurrentNID Series card Loop Protection Status for Port 1: Loop
1.3.6.1.4.1.4756.20.501.20.1.838ColumnnidLoopProtectionPort1TimeOfLastLoopRemoteAread-onlycurrentNID Series card Loop Protection Status for Port 1: Time of Last Loop
1.3.6.1.4.1.4756.20.501.20.1.839ColumnnidLoopProtectionPort2ActionStsRemoteAread-onlycurrentNID Series card Loop Protection Status for Port 2: Action
1.3.6.1.4.1.4756.20.501.20.1.840ColumnnidLoopProtectionPort2TransStsRemoteAread-onlycurrentNID Series card Loop Protection Status for Port 2: Transmit
1.3.6.1.4.1.4756.20.501.20.1.841ColumnnidLoopProtectionPort2LoopsStsRemoteAread-onlycurrentNID Series card Loop Protection Status for Port 2: Loops
1.3.6.1.4.1.4756.20.501.20.1.842ColumnnidLoopProtectionPort2StatusRemoteAread-onlycurrentNID Series card Loop Protection Status for Port 2: Status
1.3.6.1.4.1.4756.20.501.20.1.843ColumnnidLoopProtectionPort2LoopStsRemoteAread-onlycurrentNID Series card Loop Protection Status for Port 2: Loop
1.3.6.1.4.1.4756.20.501.20.1.844ColumnnidLoopProtectionPort2TimeOfLastLoopRemoteAread-onlycurrentNID Series card Loop Protection Status for Port 2: Time of Last Loop
1.3.6.1.4.1.4756.20.501.20.1.845ColumnnidLoopProtectionPort3ActionStsRemoteAread-onlycurrentNID Series card Loop Protection Status for Port 3: Action
1.3.6.1.4.1.4756.20.501.20.1.846ColumnnidLoopProtectionPort3TransStsRemoteAread-onlycurrentNID Series card Loop Protection Status for Port 3: Transmit
1.3.6.1.4.1.4756.20.501.20.1.847ColumnnidLoopProtectionPort3LoopsStsRemoteAread-onlycurrentNID Series card Loop Protection Status for Port 3: Loops
1.3.6.1.4.1.4756.20.501.20.1.848ColumnnidLoopProtectionPort3StatusRemoteAread-onlycurrentNID Series card Loop Protection Status for Port 3: Status
1.3.6.1.4.1.4756.20.501.20.1.849ColumnnidLoopProtectionPort3LoopStsRemoteAread-onlycurrentNID Series card Loop Protection Status for Port 3: Loop
1.3.6.1.4.1.4756.20.501.20.1.850ColumnnidLoopProtectionPort3TimeOfLastLoopRemoteAread-onlycurrentNID Series card Loop Protection Status for Port 3: Time of Last Loop
1.3.6.1.4.1.4756.20.501.20.1.851ColumnnidLoopProtectionPort4ActionStsRemoteAread-onlycurrentNID Series card Loop Protection Status for Port 4: Action
1.3.6.1.4.1.4756.20.501.20.1.852ColumnnidLoopProtectionPort4TransStsRemoteAread-onlycurrentNID Series card Loop Protection Status for Port 4: Transmit
1.3.6.1.4.1.4756.20.501.20.1.853ColumnnidLoopProtectionPort4LoopsStsRemoteAread-onlycurrentNID Series card Loop Protection Status for Port 4: Loops
1.3.6.1.4.1.4756.20.501.20.1.854ColumnnidLoopProtectionPort4StatusRemoteAread-onlycurrentNID Series card Loop Protection Status for Port 4: Status
1.3.6.1.4.1.4756.20.501.20.1.855ColumnnidLoopProtectionPort4LoopStsRemoteAread-onlycurrentNID Series card Loop Protection Status for Port 4: Loop
1.3.6.1.4.1.4756.20.501.20.1.856ColumnnidLoopProtectionPort4TimeOfLastLoopRemoteAread-onlycurrentNID Series card Loop Protection Status for Port 4: Time of Last Loop
1.3.6.1.4.1.4756.20.501.20.1.857ColumnnidLoopProtectionPort5ActionStsRemoteAread-onlycurrentNID Series card Loop Protection Status for Port 5: Action
1.3.6.1.4.1.4756.20.501.20.1.858ColumnnidLoopProtectionPort5TransStsRemoteAread-onlycurrentNID Series card Loop Protection Status for Port 5: Transmit
1.3.6.1.4.1.4756.20.501.20.1.859ColumnnidLoopProtectionPort5LoopsStsRemoteAread-onlycurrentNID Series card Loop Protection Status for Port 5: Loops
1.3.6.1.4.1.4756.20.501.20.1.860ColumnnidLoopProtectionPort5StatusRemoteAread-onlycurrentNID Series card Loop Protection Status for Port 5: Status
1.3.6.1.4.1.4756.20.501.20.1.861ColumnnidLoopProtectionPort5LoopStsRemoteAread-onlycurrentNID Series card Loop Protection Status for Port 5: Loop
1.3.6.1.4.1.4756.20.501.20.1.862ColumnnidLoopProtectionPort5TimeOfLastLoopRemoteAread-onlycurrentNID Series card Loop Protection Status for Port 5: Time of Last Loop
1.3.6.1.4.1.4756.20.501.20.1.863ColumnnidLoopProtectionPort6ActionStsRemoteAread-onlycurrentNID Series card Loop Protection Status for Port 6: Action
1.3.6.1.4.1.4756.20.501.20.1.864ColumnnidLoopProtectionPort6TransStsRemoteAread-onlycurrentNID Series card Loop Protection Status for Port 6: Transmit
1.3.6.1.4.1.4756.20.501.20.1.865ColumnnidLoopProtectionPort6LoopsStsRemoteAread-onlycurrentNID Series card Loop Protection Status for Port 6: Loops
1.3.6.1.4.1.4756.20.501.20.1.866ColumnnidLoopProtectionPort6StatusRemoteAread-onlycurrentNID Series card Loop Protection Status for Port 64: Status
1.3.6.1.4.1.4756.20.501.20.1.867ColumnnidLoopProtectionPort6LoopStsRemoteAread-onlycurrentNID Series card Loop Protection Status for Port 64: Loop
1.3.6.1.4.1.4756.20.501.20.1.868ColumnnidLoopProtectionPort6TimeOfLastLoopRemoteAread-onlycurrentNID Series card Loop Protection Status for Port 6: Time of Last Loop
1.3.6.1.4.1.4756.20.501.20.1.869ColumnnidLoopProtectionPort7ActionStsRemoteAread-onlycurrentNID Series card Loop Protection Status for Port 7: Action
1.3.6.1.4.1.4756.20.501.20.1.870ColumnnidLoopProtectionPort7TransStsRemoteAread-onlycurrentNID Series card Loop Protection Status for Port 7: Transmit
1.3.6.1.4.1.4756.20.501.20.1.871ColumnnidLoopProtectionPort7LoopsStsRemoteAread-onlycurrentNID Series card Loop Protection Status for Port 7: Loops
1.3.6.1.4.1.4756.20.501.20.1.872ColumnnidLoopProtectionPort7StatusRemoteAread-onlycurrentNID Series card Loop Protection Status for Port 7: Status
1.3.6.1.4.1.4756.20.501.20.1.873ColumnnidLoopProtectionPort7LoopStsRemoteAread-onlycurrentNID Series card Loop Protection Status for Port 7: Loop
1.3.6.1.4.1.4756.20.501.20.1.874ColumnnidLoopProtectionPort7TimeOfLastLoopRemoteAread-onlycurrentNID Series card Loop Protection Status for Port 7: Time of Last Loop
1.3.6.1.4.1.4756.20.501.20.1.875ColumnnidLoopProtectionPort8ActionStsRemoteAread-onlycurrentNID Series card Loop Protection Status for Port 8: Action
1.3.6.1.4.1.4756.20.501.20.1.876ColumnnidLoopProtectionPort8TransStsRemoteAread-onlycurrentNID Series card Loop Protection Status for Port 8: Transmit
1.3.6.1.4.1.4756.20.501.20.1.877ColumnnidLoopProtectionPort8LoopsStsRemoteAread-onlycurrentNID Series card Loop Protection Status for Port 8: Loops
1.3.6.1.4.1.4756.20.501.20.1.878ColumnnidLoopProtectionPort8StatusRemoteAread-onlycurrentNID Series card Loop Protection Status for Port 8: Status
1.3.6.1.4.1.4756.20.501.20.1.879ColumnnidLoopProtectionPort8LoopStsRemoteAread-onlycurrentNID Series card Loop Protection Status for Port 8: Loop
1.3.6.1.4.1.4756.20.501.20.1.880ColumnnidLoopProtectionPort8TimeOfLastLoopRemoteAread-onlycurrentNID Series card Loop Protection Status for Port 8: Time of Last Loop
1.3.6.1.4.1.4756.20.501.20.1.881ColumnniduRingInstanceAddRemoteAread-writecurrentNID Series card Add a new uRing Instance. Syntax: <Instance ID> <ring|sub|chain> <port east> <port west> Instance ID must be either 1 or 2 port east , the valu…
1.3.6.1.4.1.4756.20.501.20.1.882ColumnniduRingInstanceDeleteRemoteAread-writecurrentNID Series card Delete a uRing Instance. Syntax: <uRing Instance>
1.3.6.1.4.1.4756.20.501.20.1.883ColumnniduRingInst1IDRemoteAread-onlycurrentNID Series card u-Ring instance1 ID
1.3.6.1.4.1.4756.20.501.20.1.884ColumnniduRingInst1typeRemoteAread-onlycurrentNID Series card u-Ring instance1 type 0: u-Ring 1: Sub-Ring 2: u-Chain
1.3.6.1.4.1.4756.20.501.20.1.885ColumnniduRingInst1masterRemoteAread-writecurrentNID Series card u-Ring instance1 master 0: No 1: Yes
1.3.6.1.4.1.4756.20.501.20.1.886ColumnniduRingInst1EastPortRemoteAread-onlycurrentNID Series card u-Ring instance1 east port
1.3.6.1.4.1.4756.20.501.20.1.887ColumnniduRingInst1EastEdgeRemoteAread-writecurrentNID Series card u-Ring instance1 east edge 0: No 1: Yes
1.3.6.1.4.1.4756.20.501.20.1.888ColumnniduRingInst1WestPortRemoteAread-onlycurrentNID Series card u-Ring instance1 west port
1.3.6.1.4.1.4756.20.501.20.1.889ColumnniduRingInst1WestEdgeRemoteAread-writecurrentNID Series card u-Ring instance1 west edge 0: No 1: Yes
1.3.6.1.4.1.4756.20.501.20.1.890ColumnniduRingInst2IDRemoteAread-onlycurrentNID Series card u-Ring instance2 ID
1.3.6.1.4.1.4756.20.501.20.1.891ColumnniduRingInst2typeRemoteAread-onlycurrentNID Series card u-Ring instance2 type 0: u-Ring 1: Sub-Ring 2: u-Chain
1.3.6.1.4.1.4756.20.501.20.1.892ColumnniduRingInst2masterRemoteAread-writecurrentNID Series card u-Ring instance2 master 0: No 1: Yes
1.3.6.1.4.1.4756.20.501.20.1.893ColumnniduRingInst2EastPortRemoteAread-onlycurrentNID Series card u-Ring instance2 east port
1.3.6.1.4.1.4756.20.501.20.1.894ColumnniduRingInst2EastEdgeRemoteAread-writecurrentNID Series card u-Ring instance2 east edge 0: No 1: Yes
1.3.6.1.4.1.4756.20.501.20.1.895ColumnniduRingInst2WestPortRemoteAread-onlycurrentNID Series card u-Ring instance2 west port
1.3.6.1.4.1.4756.20.501.20.1.896ColumnniduRingInst2WestEdgeRemoteAread-writecurrentNID Series card u-Ring instance2 west edge 0: No 1: Yes
1.3.6.1.4.1.4756.20.501.20.1.897ColumnniduRingInst3IDRemoteAread-onlycurrentNID Series card u-Ring instance3 ID
1.3.6.1.4.1.4756.20.501.20.1.898ColumnniduRingInst3typeRemoteAread-onlycurrentNID Series card u-Ring instance3 type 0: u-Ring 1: Sub-Ring 2: u-Chain
1.3.6.1.4.1.4756.20.501.20.1.899ColumnniduRingInst3masterRemoteAread-writecurrentNID Series card u-Ring instance3 master 0: No 1: Yes
1.3.6.1.4.1.4756.20.501.20.1.900ColumnniduRingInst3EastPortRemoteAread-onlycurrentNID Series card u-Ring instance3 east port
1.3.6.1.4.1.4756.20.501.20.1.901ColumnniduRingInst3EastEdgeRemoteAread-writecurrentNID Series card u-Ring instance3 east edge 0: No 1: Yes
1.3.6.1.4.1.4756.20.501.20.1.902ColumnniduRingInst3WestPortRemoteAread-onlycurrentNID Series card u-Ring instance3 west port
1.3.6.1.4.1.4756.20.501.20.1.903ColumnniduRingInst3WestEdgeRemoteAread-writecurrentNID Series card u-Ring instance3 west edge 0: No 1: Yes
1.3.6.1.4.1.4756.20.501.20.1.904ColumnniduRingInst4IDRemoteAread-onlycurrentNID Series card u-Ring instance4 ID
1.3.6.1.4.1.4756.20.501.20.1.905ColumnniduRingInst4typeRemoteAread-onlycurrentNID Series card u-Ring instance4 type 0: u-Ring 1: Sub-Ring 2: u-Chain
1.3.6.1.4.1.4756.20.501.20.1.906ColumnniduRingInst4masterRemoteAread-writecurrentNID Series card u-Ring instance4 master 0: No 1: Yes
1.3.6.1.4.1.4756.20.501.20.1.907ColumnniduRingInst4EastPortRemoteAread-onlycurrentNID Series card u-Ring instance4 east port
1.3.6.1.4.1.4756.20.501.20.1.908ColumnniduRingInst4EastEdgeRemoteAread-writecurrentNID Series card u-Ring instance4 east edge 0: No 1: Yes
1.3.6.1.4.1.4756.20.501.20.1.909ColumnniduRingInst4WestPortRemoteAread-onlycurrentNID Series card u-Ring instance4 west port
1.3.6.1.4.1.4756.20.501.20.1.910ColumnniduRingInst4WestEdgeRemoteAread-writecurrentNID Series card u-Ring instance4 west edge 0: No 1: Yes
1.3.6.1.4.1.4756.20.501.20.1.911ColumnniduRingInst1IDstsRemoteAread-onlycurrentNID Series card u-Ring Instance1 ID status
1.3.6.1.4.1.4756.20.501.20.1.912ColumnniduRingInst1typestsRemoteAread-onlycurrentNID Series card u-Ring Type status
1.3.6.1.4.1.4756.20.501.20.1.913ColumnniduRingInst1rolestsRemoteAread-onlycurrentNID Series card u-Ring Role status
1.3.6.1.4.1.4756.20.501.20.1.914ColumnniduRingInst1EastPortstsRemoteAread-onlycurrentNID Series card u-Ring East port status
1.3.6.1.4.1.4756.20.501.20.1.915ColumnniduRingInst1EaststsRemoteAread-onlycurrentNID Series card u-Ring East status
1.3.6.1.4.1.4756.20.501.20.1.916ColumnniduRingInst1EastEdgestsRemoteAread-onlycurrentNID Series card u-Ring East edge status
1.3.6.1.4.1.4756.20.501.20.1.917ColumnniduRingInst1WestPortstsRemoteAread-onlycurrentNID Series card u-Ring West edge status
1.3.6.1.4.1.4756.20.501.20.1.918ColumnniduRingInst1WeststsRemoteAread-onlycurrentNID Series card u-Ring West status
1.3.6.1.4.1.4756.20.501.20.1.919ColumnniduRingInst1WestEdgestsRemoteAread-onlycurrentNID Series card u-Ring West status
1.3.6.1.4.1.4756.20.501.20.1.920ColumnniduRingInst1healthystsRemoteAread-onlycurrentNID Series card u-Ring healthy status None Fine Fault
1.3.6.1.4.1.4756.20.501.20.1.921ColumnniduRingInst2IDstsRemoteAread-onlycurrentNID Series card u-Ring Instance2 ID status
1.3.6.1.4.1.4756.20.501.20.1.922ColumnniduRingInst2typestsRemoteAread-onlycurrentNID Series card u-Ring Type status
1.3.6.1.4.1.4756.20.501.20.1.923ColumnniduRingInst2rolestsRemoteAread-onlycurrentNID Series card u-Ring Role status
1.3.6.1.4.1.4756.20.501.20.1.924ColumnniduRingInst2EastPortstsRemoteAread-onlycurrentNID Series card u-Ring East port status
1.3.6.1.4.1.4756.20.501.20.1.925ColumnniduRingInst2EaststsRemoteAread-onlycurrentNID Series card u-Ring East status
1.3.6.1.4.1.4756.20.501.20.1.926ColumnniduRingInst2EastEdgestsRemoteAread-onlycurrentNID Series card u-Ring East edge status
1.3.6.1.4.1.4756.20.501.20.1.927ColumnniduRingInst2WestPortstsRemoteAread-onlycurrentNID Series card u-Ring West edge status
1.3.6.1.4.1.4756.20.501.20.1.928ColumnniduRingInst2WeststsRemoteAread-onlycurrentNID Series card u-Ring West status
1.3.6.1.4.1.4756.20.501.20.1.929ColumnniduRingInst2WestEdgestsRemoteAread-onlycurrentNID Series card u-Ring West status
1.3.6.1.4.1.4756.20.501.20.1.930ColumnniduRingInst2healthystsRemoteAread-onlycurrentNID Series card u-Ring healthy status None Fine Fault
1.3.6.1.4.1.4756.20.501.20.1.931ColumnniduRingInst3IDstsRemoteAread-onlycurrentNID Series card u-Ring Instance3 ID status
1.3.6.1.4.1.4756.20.501.20.1.932ColumnniduRingInst3typestsRemoteAread-onlycurrentNID Series card u-Ring Type status
1.3.6.1.4.1.4756.20.501.20.1.933ColumnniduRingInst3rolestsRemoteAread-onlycurrentNID Series card u-Ring Role status
1.3.6.1.4.1.4756.20.501.20.1.934ColumnniduRingInst3EastPortstsRemoteAread-onlycurrentNID Series card u-Ring East port status
1.3.6.1.4.1.4756.20.501.20.1.935ColumnniduRingInst3EaststsRemoteAread-onlycurrentNID Series card u-Ring East status
1.3.6.1.4.1.4756.20.501.20.1.936ColumnniduRingInst3EastEdgestsRemoteAread-onlycurrentNID Series card u-Ring East edge status
1.3.6.1.4.1.4756.20.501.20.1.937ColumnniduRingInst3WestPortstsRemoteAread-onlycurrentNID Series card u-Ring West edge status
1.3.6.1.4.1.4756.20.501.20.1.938ColumnniduRingInst3WeststsRemoteAread-onlycurrentNID Series card u-Ring West status
1.3.6.1.4.1.4756.20.501.20.1.939ColumnniduRingInst3WestEdgestsRemoteAread-onlycurrentNID Series card u-Ring West status
1.3.6.1.4.1.4756.20.501.20.1.940ColumnniduRingInst3healthystsRemoteAread-onlycurrentNID Series card u-Ring healthy status None Fine Fault
1.3.6.1.4.1.4756.20.501.20.1.941ColumnniduRingInst4IDstsRemoteAread-onlycurrentNID Series card u-Ring Instance4 ID status
1.3.6.1.4.1.4756.20.501.20.1.942ColumnniduRingInst4typestsRemoteAread-onlycurrentNID Series card u-Ring Type status
1.3.6.1.4.1.4756.20.501.20.1.943ColumnniduRingInst4rolestsRemoteAread-onlycurrentNID Series card u-Ring Role status
1.3.6.1.4.1.4756.20.501.20.1.944ColumnniduRingInst4EastPortstsRemoteAread-onlycurrentNID Series card u-Ring East port status
1.3.6.1.4.1.4756.20.501.20.1.945ColumnniduRingInst4EaststsRemoteAread-onlycurrentNID Series card u-Ring East status
1.3.6.1.4.1.4756.20.501.20.1.946ColumnniduRingInst4EastEdgestsRemoteAread-onlycurrentNID Series card u-Ring East edge status
1.3.6.1.4.1.4756.20.501.20.1.947ColumnniduRingInst4WestPortstsRemoteAread-onlycurrentNID Series card u-Ring West edge status
1.3.6.1.4.1.4756.20.501.20.1.948ColumnniduRingInst4WeststsRemoteAread-onlycurrentNID Series card u-Ring West status
1.3.6.1.4.1.4756.20.501.20.1.949ColumnniduRingInst4WestEdgestsRemoteAread-onlycurrentNID Series card u-Ring West status
1.3.6.1.4.1.4756.20.501.20.1.950ColumnniduRingInst4healthystsRemoteAread-onlycurrentNID Series card u-Ring healthy status None Fine Fault
1.3.6.1.4.1.4756.20.501.20.1.951ColumnnidSTPProtocolVersionRemoteAread-writecurrentNID Series card STP Bridge Configuration: Basic Settings - Protocol Version 0: STP 1: RSTP 2: MSTP
1.3.6.1.4.1.4756.20.501.20.1.952ColumnnidSTPBridgePriorityRemoteAread-writecurrentNID Series card STP Bridge Configuration: Basic Settings - Bridge Priority 0: 0 1: 4096 2: 8192 3: 12288 4: 16384 5: 20480 6: 24576 7: 28672 8: 32768 9: 36864 …
1.3.6.1.4.1.4756.20.501.20.1.953ColumnnidSTPForwardDelayRemoteAread-writecurrentNID Series card STP Bridge Configuration: Basic Settings - Forward Delay
1.3.6.1.4.1.4756.20.501.20.1.954ColumnnidSTPMaxAgeRemoteAread-writecurrentNID Series card STP Bridge Configuration: Basic Settings - Max Age
1.3.6.1.4.1.4756.20.501.20.1.955ColumnnidSTPMaximumHopCountRemoteAread-writecurrentNID Series card STP Bridge Configuration: Basic Settings - Maximum Hop Count
1.3.6.1.4.1.4756.20.501.20.1.956ColumnnidSTPTransmitHoldCountRemoteAread-writecurrentNID Series card STP Bridge Configuration: Basic Settings - Transmit Hold Count
1.3.6.1.4.1.4756.20.501.20.1.957ColumnnidSTPEdgePortBPDUFilteringRemoteAread-writecurrentNID Series card STP Bridge Configuration: Advanced Settings - Edge Port BPDU Filtering 0: Off 1: On
1.3.6.1.4.1.4756.20.501.20.1.958ColumnnidSTPEdgePortBPDUGuardRemoteAread-writecurrentNID Series card STP Bridge Configuration: Advanced Settings - Edge Port BPDU Guard 0: Off 1: On
1.3.6.1.4.1.4756.20.501.20.1.959ColumnnidSTPPortErrorRecoveryTimeoutRemoteAread-writecurrentNID Series card STP Bridge Configuration: Advanced Settings - Port Error Recovery Timeout 0: Off 1: On
1.3.6.1.4.1.4756.20.501.20.1.960ColumnnidMSTIConfigurationNameRemoteAread-writecurrentNID Series card MSTI Configuration: Configuration Identification - Configuration Name
1.3.6.1.4.1.4756.20.501.20.1.961ColumnnidMSTIConfigurationRevisionRemoteAread-writecurrentNID Series card MSTI Configuration: Configuration Identification - Configuration Revision
1.3.6.1.4.1.4756.20.501.20.1.962ColumnnidMSTI1VLANsMappingRemoteAread-writecurrentNID Series card MSTI Configuration: MSTI Mapping - MSTI 1
1.3.6.1.4.1.4756.20.501.20.1.963ColumnnidMSTI2VLANsMappingRemoteAread-writecurrentNID Series card MSTI Configuration: MSTI Mapping - MSTI 2
1.3.6.1.4.1.4756.20.501.20.1.964ColumnnidMSTI3VLANsMappingRemoteAread-writecurrentNID Series card MSTI Configuration: MSTI Mapping - MSTI 3
1.3.6.1.4.1.4756.20.501.20.1.965ColumnnidMSTI4VLANsMappingRemoteAread-writecurrentNID Series card MSTI Configuration: MSTI Mapping - MSTI 4
1.3.6.1.4.1.4756.20.501.20.1.966ColumnnidMSTI5VLANsMappingRemoteAread-writecurrentNID Series card MSTI Configuration: MSTI Mapping - MSTI 5
1.3.6.1.4.1.4756.20.501.20.1.967ColumnnidMSTI6VLANsMappingRemoteAread-writecurrentNID Series card MSTI Configuration: MSTI Mapping - MSTI 6
1.3.6.1.4.1.4756.20.501.20.1.968ColumnnidMSTI7VLANsMappingRemoteAread-writecurrentNID Series card MSTI Configuration: MSTI Mapping - MSTI 7
1.3.6.1.4.1.4756.20.501.20.1.969ColumnnidMSTI8VLANsMappingRemoteAread-writecurrentNID Series card MSTI Configuration: MSTI Mapping - MSTI 8
1.3.6.1.4.1.4756.20.501.20.1.970ColumnnidMSTI9VLANsMappingRemoteAread-writecurrentNID Series card MSTI Configuration: MSTI Mapping - MSTI 9
1.3.6.1.4.1.4756.20.501.20.1.971ColumnnidMSTI10VLANsMappingRemoteAread-writecurrentNID Series card MSTI Configuration: MSTI Mapping - MSTI 10
1.3.6.1.4.1.4756.20.501.20.1.972ColumnnidMSTI11VLANsMappingRemoteAread-writecurrentNID Series card MSTI Configuration: MSTI Mapping - MSTI 11
1.3.6.1.4.1.4756.20.501.20.1.973ColumnnidMSTI12VLANsMappingRemoteAread-writecurrentNID Series card MSTI Configuration: MSTI Mapping - MSTI 12
1.3.6.1.4.1.4756.20.501.20.1.974ColumnnidMSTI13VLANsMappingRemoteAread-writecurrentNID Series card MSTI Configuration: MSTI Mapping - MSTI 13
1.3.6.1.4.1.4756.20.501.20.1.975ColumnnidMSTI14VLANsMappingRemoteAread-writecurrentNID Series card MSTI Configuration: MSTI Mapping - MSTI 14
1.3.6.1.4.1.4756.20.501.20.1.976ColumnnidMSTI15VLANsMappingRemoteAread-writecurrentNID Series card MSTI Configuration: MSTI Mapping - MSTI 15
1.3.6.1.4.1.4756.20.501.20.1.977ColumnnidCISTAggregatedSTPEnabledRemoteAread-writecurrentNID Series card STP CIST Port Configuration: CIST Aggregated Port Configuration - STP Enabled
1.3.6.1.4.1.4756.20.501.20.1.978ColumnnidCISTAggregatedPathCostRemoteAread-writecurrentNID Series card STP CIST Port Configuration: CIST Aggregated Port Configuration - Path Cost Valid values are in the range 0 to 200000000. Setting 0 means Auto …
1.3.6.1.4.1.4756.20.501.20.1.979ColumnnidCISTAggregatedPriorityRemoteAread-writecurrentNID Series card STP CIST Port Configuration: CIST Aggregated Port Configuration - Priority
1.3.6.1.4.1.4756.20.501.20.1.980ColumnnidCISTAggregatedAdminEdgeRemoteAread-writecurrentNID Series card STP CIST Port Configuration: CIST Aggregated Port Configuration - STP Enabled 0: Non-edge 1: Edge
1.3.6.1.4.1.4756.20.501.20.1.981ColumnnidCISTAggregatedAutoEdgeRemoteAread-writecurrentNID Series card STP CIST Port Configuration: CIST Aggregated Port Configuration - Auto Edge 0: Non-edge 1: Edge
1.3.6.1.4.1.4756.20.501.20.1.982ColumnnidCISTAggregatedRestrictedRoleRemoteAread-writecurrentNID Series card STP CIST Port Configuration: CIST Aggregated Port Configuration - Restricted Role 0: Non-edge 1: Edge
1.3.6.1.4.1.4756.20.501.20.1.983ColumnnidCISTAggregatedRestrictedTCNRemoteAread-writecurrentNID Series card STP CIST Port Configuration: CIST Aggregated Port Configuration - Restricted TCN 0: Non-edge 1: Edge
1.3.6.1.4.1.4756.20.501.20.1.984ColumnnidCISTAggregatedBPDUGuardRemoteAread-writecurrentNID Series card STP CIST Port Configuration: CIST Aggregated Port Configuration - BPDU Guard 0: Non-edge 1: Edge
1.3.6.1.4.1.4756.20.501.20.1.985ColumnnidCISTAggregatedPointToPointRemoteAread-writecurrentNID Series card STP CIST Port Configuration: CIST Aggregated Port Configuration - Point-to-point 0: Forced True 1: Forced False 2: Auto
1.3.6.1.4.1.4756.20.501.20.1.986ColumnnidCISTPort1STPEnabledRemoteAread-writecurrentNID Series card STP CIST Port Configuration: CIST Normal Port1 Configuration - STP Enabled
1.3.6.1.4.1.4756.20.501.20.1.987ColumnnidCISTPort1PathCostRemoteAread-writecurrentNID Series card STP CIST Port Configuration: CIST Normal Port1 Configuration - Path Cost Valid values are in the range 0 to 200000000. Setting 0 means Auto pat…
1.3.6.1.4.1.4756.20.501.20.1.988ColumnnidCISTPort1PriorityRemoteAread-writecurrentNID Series card STP CIST Port Configuration: CIST Normal Port1 Configuration - Priority
1.3.6.1.4.1.4756.20.501.20.1.989ColumnnidCISTPort1AdminEdgeRemoteAread-writecurrentNID Series card STP CIST Port Configuration: CIST Normal Port1 Configuration - STP Enabled 0: Non-edge 1: Edge
1.3.6.1.4.1.4756.20.501.20.1.990ColumnnidCISTPort1AutoEdgeRemoteAread-writecurrentNID Series card STP CIST Port Configuration: CIST Normal Port1 Configuration - Auto Edge 0: Non-edge 1: Edge
1.3.6.1.4.1.4756.20.501.20.1.991ColumnnidCISTPort1RestrictedRoleRemoteAread-writecurrentNID Series card STP CIST Port Configuration: CIST Normal Port1 Configuration - Restricted Role 0: Non-edge 1: Edge
1.3.6.1.4.1.4756.20.501.20.1.992ColumnnidCISTPort1RestrictedTCNRemoteAread-writecurrentNID Series card STP CIST Port Configuration: CIST Normal Port1 Configuration - Restricted TCN 0: Non-edge 1: Edge
1.3.6.1.4.1.4756.20.501.20.1.993ColumnnidCISTPort1BPDUGuardRemoteAread-writecurrentNID Series card STP CIST Port Configuration: CIST Normal Port1 Configuration - BPDU Guard 0: Non-edge 1: Edge
1.3.6.1.4.1.4756.20.501.20.1.994ColumnnidCISTPort1PointToPointRemoteAread-writecurrentNID Series card STP CIST Port Configuration: CIST Normal Port1 Configuration - Point-to-point 0: Forced True 1: Forced False 2: Auto
1.3.6.1.4.1.4756.20.501.20.1.995ColumnnidCISTPort2STPEnabledRemoteAread-writecurrentNID Series card STP CIST Port Configuration: CIST Normal Port2 Configuration - STP Enabled
1.3.6.1.4.1.4756.20.501.20.1.996ColumnnidCISTPort2PathCostRemoteAread-writecurrentNID Series card STP CIST Port Configuration: CIST Normal Port2 Configuration - Path Cost Valid values are in the range 0 to 200000000. Setting 0 means Auto pat…
1.3.6.1.4.1.4756.20.501.20.1.997ColumnnidCISTPort2PriorityRemoteAread-writecurrentNID Series card STP CIST Port Configuration: CIST Normal Port2 Configuration - Priority
1.3.6.1.4.1.4756.20.501.20.1.998ColumnnidCISTPort2AdminEdgeRemoteAread-writecurrentNID Series card STP CIST Port Configuration: CIST Normal Port2 Configuration - STP Enabled 0: Non-edge 1: Edge
1.3.6.1.4.1.4756.20.501.20.1.999ColumnnidCISTPort2AutoEdgeRemoteAread-writecurrentNID Series card STP CIST Port Configuration: CIST Normal Port2 Configuration - Auto Edge 0: Non-edge 1: Edge
1.3.6.1.4.1.4756.20.501.20.1.1000ColumnnidCISTPort2RestrictedRoleRemoteAread-writecurrentNID Series card STP CIST Port Configuration: CIST Normal Port2 Configuration - Restricted Role 0: Non-edge 1: Edge
1.3.6.1.4.1.4756.20.501.20.1.1001ColumnnidCISTPort2RestrictedTCNRemoteAread-writecurrentNID Series card STP CIST Port Configuration: CIST Normal Port2 Configuration - Restricted TCN 0: Non-edge 1: Edge
1.3.6.1.4.1.4756.20.501.20.1.1002ColumnnidCISTPort2BPDUGuardRemoteAread-writecurrentNID Series card STP CIST Port Configuration: CIST Normal Port2 Configuration - BPDU Guard 0: Non-edge 1: Edge
1.3.6.1.4.1.4756.20.501.20.1.1003ColumnnidCISTPort2PointToPointRemoteAread-writecurrentNID Series card STP CIST Port Configuration: CIST Normal Port2 Configuration - Point-to-point 0: Forced True 1: Forced False 2: Auto
1.3.6.1.4.1.4756.20.501.20.1.1004ColumnnidCISTPort3STPEnabledRemoteAread-writecurrentNID Series card STP CIST Port Configuration: CIST Normal Port3 Configuration - STP Enabled
1.3.6.1.4.1.4756.20.501.20.1.1005ColumnnidCISTPort3PathCostRemoteAread-writecurrentNID Series card STP CIST Port Configuration: CIST Normal Port3 Configuration - Path Cost Valid values are in the range 0 to 200000000. Setting 0 means Auto pat…
1.3.6.1.4.1.4756.20.501.20.1.1006ColumnnidCISTPort3PriorityRemoteAread-writecurrentNID Series card STP CIST Port Configuration: CIST Normal Port3 Configuration - Priority
1.3.6.1.4.1.4756.20.501.20.1.1007ColumnnidCISTPort3AdminEdgeRemoteAread-writecurrentNID Series card STP CIST Port Configuration: CIST Normal Port3 Configuration - STP Enabled 0: Non-edge 1: Edge
1.3.6.1.4.1.4756.20.501.20.1.1008ColumnnidCISTPort3AutoEdgeRemoteAread-writecurrentNID Series card STP CIST Port Configuration: CIST Normal Port3 Configuration - Auto Edge 0: Non-edge 1: Edge
1.3.6.1.4.1.4756.20.501.20.1.1009ColumnnidCISTPort3RestrictedRoleRemoteAread-writecurrentNID Series card STP CIST Port Configuration: CIST Normal Port3 Configuration - Restricted Role 0: Non-edge 1: Edge
1.3.6.1.4.1.4756.20.501.20.1.1010ColumnnidCISTPort3RestrictedTCNRemoteAread-writecurrentNID Series card STP CIST Port Configuration: CIST Normal Port3 Configuration - Restricted TCN 0: Non-edge 1: Edge
1.3.6.1.4.1.4756.20.501.20.1.1011ColumnnidCISTPort3BPDUGuardRemoteAread-writecurrentNID Series card STP CIST Port Configuration: CIST Normal Port3 Configuration - BPDU Guard 0: Non-edge 1: Edge
1.3.6.1.4.1.4756.20.501.20.1.1012ColumnnidCISTPort3PointToPointRemoteAread-writecurrentNID Series card STP CIST Port Configuration: CIST Normal Port3 Configuration - Point-to-point 0: Forced True 1: Forced False 2: Auto
1.3.6.1.4.1.4756.20.501.20.1.1013ColumnnidCISTPort4STPEnabledRemoteAread-writecurrentNID Series card STP CIST Port Configuration: CIST Normal Port4 Configuration - STP Enabled
1.3.6.1.4.1.4756.20.501.20.1.1014ColumnnidCISTPort4PathCostRemoteAread-writecurrentNID Series card STP CIST Port Configuration: CIST Normal Port4 Configuration - Path Cost Valid values are in the range 0 to 200000000. Setting 0 means Auto pat…
1.3.6.1.4.1.4756.20.501.20.1.1015ColumnnidCISTPort4PriorityRemoteAread-writecurrentNID Series card STP CIST Port Configuration: CIST Normal Port4 Configuration - Priority
1.3.6.1.4.1.4756.20.501.20.1.1016ColumnnidCISTPort4AdminEdgeRemoteAread-writecurrentNID Series card STP CIST Port Configuration: CIST Normal Port4 Configuration - STP Enabled 0: Non-edge 1: Edge
1.3.6.1.4.1.4756.20.501.20.1.1017ColumnnidCISTPort4AutoEdgeRemoteAread-writecurrentNID Series card STP CIST Port Configuration: CIST Normal Port4 Configuration - Auto Edge 0: Non-edge 1: Edge
1.3.6.1.4.1.4756.20.501.20.1.1018ColumnnidCISTPort4RestrictedRoleRemoteAread-writecurrentNID Series card STP CIST Port Configuration: CIST Normal Port4 Configuration - Restricted Role 0: Non-edge 1: Edge
1.3.6.1.4.1.4756.20.501.20.1.1019ColumnnidCISTPort4RestrictedTCNRemoteAread-writecurrentNID Series card STP CIST Port Configuration: CIST Normal Port4 Configuration - Restricted TCN 0: Non-edge 1: Edge
1.3.6.1.4.1.4756.20.501.20.1.1020ColumnnidCISTPort4BPDUGuardRemoteAread-writecurrentNID Series card STP CIST Port Configuration: CIST Normal Port4 Configuration - BPDU Guard 0: Non-edge 1: Edge
1.3.6.1.4.1.4756.20.501.20.1.1021ColumnnidCISTPort4PointToPointRemoteAread-writecurrentNID Series card STP CIST Port Configuration: CIST Normal Port4 Configuration - Point-to-point 0: Forced True 1: Forced False 2: Auto
1.3.6.1.4.1.4756.20.501.20.1.1022ColumnnidCISTPort5STPEnabledRemoteAread-writecurrentNID Series card STP CIST Port Configuration: CIST Normal Port5 Configuration - STP Enabled
1.3.6.1.4.1.4756.20.501.20.1.1023ColumnnidCISTPort5PathCostRemoteAread-writecurrentNID Series card STP CIST Port Configuration: CIST Normal Port5 Configuration - Path Cost Valid values are in the range 0 to 200000000. Setting 0 means Auto pat…
1.3.6.1.4.1.4756.20.501.20.1.1024ColumnnidCISTPort5PriorityRemoteAread-writecurrentNID Series card STP CIST Port Configuration: CIST Normal Port5 Configuration - Priority
1.3.6.1.4.1.4756.20.501.20.1.1025ColumnnidCISTPort5AdminEdgeRemoteAread-writecurrentNID Series card STP CIST Port Configuration: CIST Normal Port5 Configuration - STP Enabled 0: Non-edge 1: Edge
1.3.6.1.4.1.4756.20.501.20.1.1026ColumnnidCISTPort5AutoEdgeRemoteAread-writecurrentNID Series card STP CIST Port Configuration: CIST Normal Port5 Configuration - Auto Edge 0: Non-edge 1: Edge
1.3.6.1.4.1.4756.20.501.20.1.1027ColumnnidCISTPort5RestrictedRoleRemoteAread-writecurrentNID Series card STP CIST Port Configuration: CIST Normal Port5 Configuration - Restricted Role 0: Non-edge 1: Edge
1.3.6.1.4.1.4756.20.501.20.1.1028ColumnnidCISTPort5RestrictedTCNRemoteAread-writecurrentNID Series card STP CIST Port Configuration: CIST Normal Port5 Configuration - Restricted TCN 0: Non-edge 1: Edge
1.3.6.1.4.1.4756.20.501.20.1.1029ColumnnidCISTPort5BPDUGuardRemoteAread-writecurrentNID Series card STP CIST Port Configuration: CIST Normal Port5 Configuration - BPDU Guard 0: Non-edge 1: Edge
1.3.6.1.4.1.4756.20.501.20.1.1030ColumnnidCISTPort5PointToPointRemoteAread-writecurrentNID Series card STP CIST Port Configuration: CIST Normal Port5 Configuration - Point-to-point 0: Forced True 1: Forced False 2: Auto
1.3.6.1.4.1.4756.20.501.20.1.1031ColumnnidCISTPort6STPEnabledRemoteAread-writecurrentNID Series card STP CIST Port Configuration: CIST Normal Port6 Configuration - STP Enabled
1.3.6.1.4.1.4756.20.501.20.1.1032ColumnnidCISTPort6PathCostRemoteAread-writecurrentNID Series card STP CIST Port Configuration: CIST Normal Port6 Configuration - Path Cost Valid values are in the range 0 to 200000000. Setting 0 means Auto pat…
1.3.6.1.4.1.4756.20.501.20.1.1033ColumnnidCISTPort6PriorityRemoteAread-writecurrentNID Series card STP CIST Port Configuration: CIST Normal Port6 Configuration - Priority
1.3.6.1.4.1.4756.20.501.20.1.1034ColumnnidCISTPort6AdminEdgeRemoteAread-writecurrentNID Series card STP CIST Port Configuration: CIST Normal Port6 Configuration - STP Enabled 0: Non-edge 1: Edge
1.3.6.1.4.1.4756.20.501.20.1.1035ColumnnidCISTPort6AutoEdgeRemoteAread-writecurrentNID Series card STP CIST Port Configuration: CIST Normal Port6 Configuration - Auto Edge 0: Non-edge 1: Edge
1.3.6.1.4.1.4756.20.501.20.1.1036ColumnnidCISTPort6RestrictedRoleRemoteAread-writecurrentNID Series card STP CIST Port Configuration: CIST Normal Port6 Configuration - Restricted Role 0: Non-edge 1: Edge
1.3.6.1.4.1.4756.20.501.20.1.1037ColumnnidCISTPort6RestrictedTCNRemoteAread-writecurrentNID Series card STP CIST Port Configuration: CIST Normal Port6 Configuration - Restricted TCN 0: Non-edge 1: Edge
1.3.6.1.4.1.4756.20.501.20.1.1038ColumnnidCISTPort6BPDUGuardRemoteAread-writecurrentNID Series card STP CIST Port Configuration: CIST Normal Port6 Configuration - BPDU Guard 0: Non-edge 1: Edge
1.3.6.1.4.1.4756.20.501.20.1.1039ColumnnidCISTPort6PointToPointRemoteAread-writecurrentNID Series card STP CIST Port Configuration: CIST Normal Port6 Configuration - Point-to-point 0: Forced True 1: Forced False 2: Auto
1.3.6.1.4.1.4756.20.501.20.1.1040ColumnnidCISTPort7STPEnabledRemoteAread-writecurrentNID Series card STP CIST Port Configuration: CIST Normal Port7 Configuration - STP Enabled
1.3.6.1.4.1.4756.20.501.20.1.1041ColumnnidCISTPort7PathCostRemoteAread-writecurrentNID Series card STP CIST Port Configuration: CIST Normal Port7 Configuration - Path Cost Valid values are in the range 0 to 200000000. Setting 0 means Auto pat…
1.3.6.1.4.1.4756.20.501.20.1.1042ColumnnidCISTPort7PriorityRemoteAread-writecurrentNID Series card STP CIST Port Configuration: CIST Normal Port7 Configuration - Priority
1.3.6.1.4.1.4756.20.501.20.1.1043ColumnnidCISTPort7AdminEdgeRemoteAread-writecurrentNID Series card STP CIST Port Configuration: CIST Normal Port7 Configuration - STP Enabled 0: Non-edge 1: Edge
1.3.6.1.4.1.4756.20.501.20.1.1044ColumnnidCISTPort7AutoEdgeRemoteAread-writecurrentNID Series card STP CIST Port Configuration: CIST Normal Port7 Configuration - Auto Edge 0: Non-edge 1: Edge
1.3.6.1.4.1.4756.20.501.20.1.1045ColumnnidCISTPort7RestrictedRoleRemoteAread-writecurrentNID Series card STP CIST Port Configuration: CIST Normal Port7 Configuration - Restricted Role 0: Non-edge 1: Edge
1.3.6.1.4.1.4756.20.501.20.1.1046ColumnnidCISTPort7RestrictedTCNRemoteAread-writecurrentNID Series card STP CIST Port Configuration: CIST Normal Port7 Configuration - Restricted TCN 0: Non-edge 1: Edge
1.3.6.1.4.1.4756.20.501.20.1.1047ColumnnidCISTPort7BPDUGuardRemoteAread-writecurrentNID Series card STP CIST Port Configuration: CIST Normal Port7 Configuration - BPDU Guard 0: Non-edge 1: Edge
1.3.6.1.4.1.4756.20.501.20.1.1048ColumnnidCISTPort7PointToPointRemoteAread-writecurrentNID Series card STP CIST Port Configuration: CIST Normal Port7 Configuration - Point-to-point 0: Forced True 1: Forced False 2: Auto
1.3.6.1.4.1.4756.20.501.20.1.1049ColumnnidCISTPort8STPEnabledRemoteAread-writecurrentNID Series card STP CIST Port Configuration: CIST Normal Port8 Configuration - STP Enabled
1.3.6.1.4.1.4756.20.501.20.1.1050ColumnnidCISTPort8PathCostRemoteAread-writecurrentNID Series card STP CIST Port Configuration: CIST Normal Port8 Configuration - Path Cost Valid values are in the range 0 to 200000000. Setting 0 means Auto pat…
1.3.6.1.4.1.4756.20.501.20.1.1051ColumnnidCISTPort8PriorityRemoteAread-writecurrentNID Series card STP CIST Port Configuration: CIST Normal Port8 Configuration - Priority
1.3.6.1.4.1.4756.20.501.20.1.1052ColumnnidCISTPort8AdminEdgeRemoteAread-writecurrentNID Series card STP CIST Port Configuration: CIST Normal Port8 Configuration - STP Enabled 0: Non-edge 1: Edge
1.3.6.1.4.1.4756.20.501.20.1.1053ColumnnidCISTPort8AutoEdgeRemoteAread-writecurrentNID Series card STP CIST Port Configuration: CIST Normal Port8 Configuration - Auto Edge 0: Non-edge 1: Edge
1.3.6.1.4.1.4756.20.501.20.1.1054ColumnnidCISTPort8RestrictedRoleRemoteAread-writecurrentNID Series card STP CIST Port Configuration: CIST Normal Port8 Configuration - Restricted Role 0: Non-edge 1: Edge
1.3.6.1.4.1.4756.20.501.20.1.1055ColumnnidCISTPort8RestrictedTCNRemoteAread-writecurrentNID Series card STP CIST Port Configuration: CIST Normal Port8 Configuration - Restricted TCN 0: Non-edge 1: Edge
1.3.6.1.4.1.4756.20.501.20.1.1056ColumnnidCISTPort8BPDUGuardRemoteAread-writecurrentNID Series card STP CIST Port Configuration: CIST Normal Port8 Configuration - BPDU Guard 0: Non-edge 1: Edge
1.3.6.1.4.1.4756.20.501.20.1.1057ColumnnidCISTPort8PointToPointRemoteAread-writecurrentNID Series card STP CIST Port Configuration: CIST Normal Port8 Configuration - Point-to-point 0: Forced True 1: Forced False 2: Auto
1.3.6.1.4.1.4756.20.501.20.1.1058ColumnnidMSTI1AggregatedPathCostRemoteAread-writecurrentNID Series card MSTI Port Configuration: MSTI1 Aggregated Ports Configuration - Path Cost Valid values are in the range 0 to 200000000. Setting 0 means Auto pa…
1.3.6.1.4.1.4756.20.501.20.1.1059ColumnnidMSTI1AggregatedPriorityRemoteAread-writecurrentNID Series card MSTI Port Configuration: MSTI1 Aggregated Ports Configuration - Priority
1.3.6.1.4.1.4756.20.501.20.1.1060ColumnnidMSTI1Port1PathCostRemoteAread-writecurrentNID Series card MSTI Port Configuration: MSTI1 Normal Port1 Configuration - Path Cost Valid values are in the range 0 to 200000000. Setting 0 means Auto path c…
1.3.6.1.4.1.4756.20.501.20.1.1061ColumnnidMSTI1Port1PriorityRemoteAread-writecurrentNID Series card MSTI Port Configuration: MSTI1 Normal Port1 Configuration - Priority
1.3.6.1.4.1.4756.20.501.20.1.1062ColumnnidMSTI1Port2PathCostRemoteAread-writecurrentNID Series card MSTI Port Configuration: MSTI1 Normal Port2 Configuration - Path Cost Valid values are in the range 0 to 200000000. Setting 0 means Auto path c…
1.3.6.1.4.1.4756.20.501.20.1.1063ColumnnidMSTI1Port2PriorityRemoteAread-writecurrentNID Series card MSTI Port Configuration: MSTI1 Normal Port2 Configuration - Priority
1.3.6.1.4.1.4756.20.501.20.1.1064ColumnnidMSTI1Port3PathCostRemoteAread-writecurrentNID Series card MSTI Port Configuration: MSTI1 Normal Port3 Configuration - Path Cost Valid values are in the range 0 to 200000000. Setting 0 means Auto path c…
1.3.6.1.4.1.4756.20.501.20.1.1065ColumnnidMSTI1Port3PriorityRemoteAread-writecurrentNID Series card MSTI Port Configuration: MSTI1 Normal Port3 Configuration - Priority
1.3.6.1.4.1.4756.20.501.20.1.1066ColumnnidMSTI1Port4PathCostRemoteAread-writecurrentNID Series card MSTI Port Configuration: MSTI1 Normal Port4 Configuration - Path Cost Valid values are in the range 0 to 200000000. Setting 0 means Auto path c…
1.3.6.1.4.1.4756.20.501.20.1.1067ColumnnidMSTI1Port4PriorityRemoteAread-writecurrentNID Series card MSTI Port Configuration: MSTI1 Normal Port4 Configuration - Priority
1.3.6.1.4.1.4756.20.501.20.1.1068ColumnnidMSTI1Port5PathCostRemoteAread-writecurrentNID Series card MSTI Port Configuration: MSTI1 Normal Port5 Configuration - Path Cost Valid values are in the range 0 to 200000000. Setting 0 means Auto path c…
1.3.6.1.4.1.4756.20.501.20.1.1069ColumnnidMSTI1Port5PriorityRemoteAread-writecurrentNID Series card MSTI Port Configuration: MSTI1 Normal Port5 Configuration - Priority
1.3.6.1.4.1.4756.20.501.20.1.1070ColumnnidMSTI1Port6PathCostRemoteAread-writecurrentNID Series card MSTI Port Configuration: MSTI1 Normal Port6 Configuration - Path Cost Valid values are in the range 0 to 200000000. Setting 0 means Auto path c…
1.3.6.1.4.1.4756.20.501.20.1.1071ColumnnidMSTI1Port6PriorityRemoteAread-writecurrentNID Series card MSTI Port Configuration: MSTI1 Normal Port6 Configuration - Priority
1.3.6.1.4.1.4756.20.501.20.1.1072ColumnnidMSTI1Port7PathCostRemoteAread-writecurrentNID Series card MSTI Port Configuration: MSTI1 Normal Port7 Configuration - Path Cost Valid values are in the range 0 to 200000000. Setting 0 means Auto path c…
1.3.6.1.4.1.4756.20.501.20.1.1073ColumnnidMSTI1Port7PriorityRemoteAread-writecurrentNID Series card MSTI Port Configuration: MSTI1 Normal Port7 Configuration - Priority
1.3.6.1.4.1.4756.20.501.20.1.1074ColumnnidMSTI1Port8PathCostRemoteAread-writecurrentNID Series card MSTI Port Configuration: MSTI1 Normal Port8 Configuration - Path Cost Valid values are in the range 0 to 200000000. Setting 0 means Auto path c…
1.3.6.1.4.1.4756.20.501.20.1.1075ColumnnidMSTI1Port8PriorityRemoteAread-writecurrentNID Series card MSTI Port Configuration: MSTI1 Normal Port8 Configuration - Priority
1.3.6.1.4.1.4756.20.501.20.1.1076ColumnnidMSTI2AggregatedPathCostRemoteAread-writecurrentNID Series card MSTI Port Configuration: MSTI2 Aggregated Ports Configuration - Path Cost Valid values are in the range 0 to 200000000. Setting 0 means Auto pa…
1.3.6.1.4.1.4756.20.501.20.1.1077ColumnnidMSTI2AggregatedPriorityRemoteAread-writecurrentNID Series card MSTI Port Configuration: MSTI2 Aggregated Ports Configuration - Priority
1.3.6.1.4.1.4756.20.501.20.1.1078ColumnnidMSTI2Port1PathCostRemoteAread-writecurrentNID Series card MSTI Port Configuration: MSTI2 Normal Port1 Configuration - Path Cost Valid values are in the range 0 to 200000000. Setting 0 means Auto path c…
1.3.6.1.4.1.4756.20.501.20.1.1079ColumnnidMSTI2Port1PriorityRemoteAread-writecurrentNID Series card MSTI Port Configuration: MSTI2 Normal Port1 Configuration - Priority
1.3.6.1.4.1.4756.20.501.20.1.1080ColumnnidMSTI2Port2PathCostRemoteAread-writecurrentNID Series card MSTI Port Configuration: MSTI2 Normal Port2 Configuration - Path Cost Valid values are in the range 0 to 200000000. Setting 0 means Auto path c…
1.3.6.1.4.1.4756.20.501.20.1.1081ColumnnidMSTI2Port2PriorityRemoteAread-writecurrentNID Series card MSTI Port Configuration: MSTI2 Normal Port2 Configuration - Priority
1.3.6.1.4.1.4756.20.501.20.1.1082ColumnnidMSTI2Port3PathCostRemoteAread-writecurrentNID Series card MSTI Port Configuration: MSTI2 Normal Port3 Configuration - Path Cost Valid values are in the range 0 to 200000000. Setting 0 means Auto path c…
1.3.6.1.4.1.4756.20.501.20.1.1083ColumnnidMSTI2Port3PriorityRemoteAread-writecurrentNID Series card MSTI Port Configuration: MSTI2 Normal Port3 Configuration - Priority
1.3.6.1.4.1.4756.20.501.20.1.1084ColumnnidMSTI2Port4PathCostRemoteAread-writecurrentNID Series card MSTI Port Configuration: MSTI2 Normal Port4 Configuration - Path Cost Valid values are in the range 0 to 200000000. Setting 0 means Auto path c…
1.3.6.1.4.1.4756.20.501.20.1.1085ColumnnidMSTI2Port4PriorityRemoteAread-writecurrentNID Series card MSTI Port Configuration: MSTI2 Normal Port4 Configuration - Priority
1.3.6.1.4.1.4756.20.501.20.1.1086ColumnnidMSTI2Port5PathCostRemoteAread-writecurrentNID Series card MSTI Port Configuration: MSTI2 Normal Port5 Configuration - Path Cost Valid values are in the range 0 to 200000000. Setting 0 means Auto path c…
1.3.6.1.4.1.4756.20.501.20.1.1087ColumnnidMSTI2Port5PriorityRemoteAread-writecurrentNID Series card MSTI Port Configuration: MSTI2 Normal Port5 Configuration - Priority
1.3.6.1.4.1.4756.20.501.20.1.1088ColumnnidMSTI2Port6PathCostRemoteAread-writecurrentNID Series card MSTI Port Configuration: MSTI2 Normal Port6 Configuration - Path Cost Valid values are in the range 0 to 200000000. Setting 0 means Auto path c…
1.3.6.1.4.1.4756.20.501.20.1.1089ColumnnidMSTI2Port6PriorityRemoteAread-writecurrentNID Series card MSTI Port Configuration: MSTI2 Normal Port6 Configuration - Priority
1.3.6.1.4.1.4756.20.501.20.1.1090ColumnnidMSTI2Port7PathCostRemoteAread-writecurrentNID Series card MSTI Port Configuration: MSTI2 Normal Port7 Configuration - Path Cost Valid values are in the range 0 to 200000000. Setting 0 means Auto path c…
1.3.6.1.4.1.4756.20.501.20.1.1091ColumnnidMSTI2Port7PriorityRemoteAread-writecurrentNID Series card MSTI Port Configuration: MSTI2 Normal Port7 Configuration - Priority
1.3.6.1.4.1.4756.20.501.20.1.1092ColumnnidMSTI2Port8PathCostRemoteAread-writecurrentNID Series card MSTI Port Configuration: MSTI2 Normal Port8 Configuration - Path Cost Valid values are in the range 0 to 200000000. Setting 0 means Auto path c…
1.3.6.1.4.1.4756.20.501.20.1.1093ColumnnidMSTI2Port8PriorityRemoteAread-writecurrentNID Series card MSTI Port Configuration: MSTI2 Normal Port8 Configuration - Priority
1.3.6.1.4.1.4756.20.501.20.1.1094ColumnnidMSTI3AggregatedPathCostRemoteAread-writecurrentNID Series card MSTI Port Configuration: MSTI3 Aggregated Ports Configuration - Path Cost Valid values are in the range 0 to 200000000. Setting 0 means Auto pa…
1.3.6.1.4.1.4756.20.501.20.1.1095ColumnnidMSTI3AggregatedPriorityRemoteAread-writecurrentNID Series card MSTI Port Configuration: MSTI3 Aggregated Ports Configuration - Priority
1.3.6.1.4.1.4756.20.501.20.1.1096ColumnnidMSTI3Port1PathCostRemoteAread-writecurrentNID Series card MSTI Port Configuration: MSTI3 Normal Port1 Configuration - Path Cost Valid values are in the range 0 to 200000000. Setting 0 means Auto path c…
1.3.6.1.4.1.4756.20.501.20.1.1097ColumnnidMSTI3Port1PriorityRemoteAread-writecurrentNID Series card MSTI Port Configuration: MSTI3 Normal Port1 Configuration - Priority
1.3.6.1.4.1.4756.20.501.20.1.1098ColumnnidMSTI3Port2PathCostRemoteAread-writecurrentNID Series card MSTI Port Configuration: MSTI3 Normal Port2 Configuration - Path Cost Valid values are in the range 0 to 200000000. Setting 0 means Auto path c…
1.3.6.1.4.1.4756.20.501.20.1.1099ColumnnidMSTI3Port2PriorityRemoteAread-writecurrentNID Series card MSTI Port Configuration: MSTI3 Normal Port2 Configuration - Priority
1.3.6.1.4.1.4756.20.501.20.1.1100ColumnnidMSTI3Port3PathCostRemoteAread-writecurrentNID Series card MSTI Port Configuration: MSTI1 Normal Port3 Configuration - Path Cost Valid values are in the range 0 to 200000000. Setting 0 means Auto path c…
1.3.6.1.4.1.4756.20.501.20.1.1101ColumnnidMSTI3Port3PriorityRemoteAread-writecurrentNID Series card MSTI Port Configuration: MSTI3 Normal Port3 Configuration - Priority
1.3.6.1.4.1.4756.20.501.20.1.1102ColumnnidMSTI3Port4PathCostRemoteAread-writecurrentNID Series card MSTI Port Configuration: MSTI3 Normal Port4 Configuration - Path Cost Valid values are in the range 0 to 200000000. Setting 0 means Auto path c…
1.3.6.1.4.1.4756.20.501.20.1.1103ColumnnidMSTI3Port4PriorityRemoteAread-writecurrentNID Series card MSTI Port Configuration: MSTI3 Normal Port4 Configuration - Priority
1.3.6.1.4.1.4756.20.501.20.1.1104ColumnnidMSTI3Port5PathCostRemoteAread-writecurrentNID Series card MSTI Port Configuration: MSTI3 Normal Port5 Configuration - Path Cost Valid values are in the range 0 to 200000000. Setting 0 means Auto path c…
1.3.6.1.4.1.4756.20.501.20.1.1105ColumnnidMSTI3Port5PriorityRemoteAread-writecurrentNID Series card MSTI Port Configuration: MSTI3 Normal Port5 Configuration - Priority
1.3.6.1.4.1.4756.20.501.20.1.1106ColumnnidMSTI3Port6PathCostRemoteAread-writecurrentNID Series card MSTI Port Configuration: MSTI3 Normal Port6 Configuration - Path Cost Valid values are in the range 0 to 200000000. Setting 0 means Auto path c…
1.3.6.1.4.1.4756.20.501.20.1.1107ColumnnidMSTI3Port6PriorityRemoteAread-writecurrentNID Series card MSTI Port Configuration: MSTI3 Normal Port6 Configuration - Priority
1.3.6.1.4.1.4756.20.501.20.1.1108ColumnnidMSTI3Port7PathCostRemoteAread-writecurrentNID Series card MSTI Port Configuration: MSTI3 Normal Port7 Configuration - Path Cost Valid values are in the range 0 to 200000000. Setting 0 means Auto path c…
1.3.6.1.4.1.4756.20.501.20.1.1109ColumnnidMSTI3Port7PriorityRemoteAread-writecurrentNID Series card MSTI Port Configuration: MSTI3 Normal Port7 Configuration - Priority
1.3.6.1.4.1.4756.20.501.20.1.1110ColumnnidMSTI3Port8PathCostRemoteAread-writecurrentNID Series card MSTI Port Configuration: MSTI3 Normal Port8 Configuration - Path Cost Valid values are in the range 0 to 200000000. Setting 0 means Auto path c…
1.3.6.1.4.1.4756.20.501.20.1.1111ColumnnidMSTI3Port8PriorityRemoteAread-writecurrentNID Series card MSTI Port Configuration: MSTI3 Normal Port8 Configuration - Priority
1.3.6.1.4.1.4756.20.501.20.1.1112ColumnnidMSTI4AggregatedPathCostRemoteAread-writecurrentNID Series card MSTI Port Configuration: MSTI4 Aggregated Ports Configuration - Path Cost Valid values are in the range 0 to 200000000. Setting 0 means Auto pa…
1.3.6.1.4.1.4756.20.501.20.1.1113ColumnnidMSTI4AggregatedPriorityRemoteAread-writecurrentNID Series card MSTI Port Configuration: MSTI4 Aggregated Ports Configuration - Priority
1.3.6.1.4.1.4756.20.501.20.1.1114ColumnnidMSTI4Port1PathCostRemoteAread-writecurrentNID Series card MSTI Port Configuration: MSTI4 Normal Port1 Configuration - Path Cost Valid values are in the range 0 to 200000000. Setting 0 means Auto path c…
1.3.6.1.4.1.4756.20.501.20.1.1115ColumnnidMSTI4Port1PriorityRemoteAread-writecurrentNID Series card MSTI Port Configuration: MSTI4 Normal Port1 Configuration - Priority
1.3.6.1.4.1.4756.20.501.20.1.1116ColumnnidMSTI4Port2PathCostRemoteAread-writecurrentNID Series card MSTI Port Configuration: MSTI4 Normal Port2 Configuration - Path Cost Valid values are in the range 0 to 200000000. Setting 0 means Auto path c…
1.3.6.1.4.1.4756.20.501.20.1.1117ColumnnidMSTI4Port2PriorityRemoteAread-writecurrentNID Series card MSTI Port Configuration: MSTI4 Normal Port2 Configuration - Priority
1.3.6.1.4.1.4756.20.501.20.1.1118ColumnnidMSTI4Port3PathCostRemoteAread-writecurrentNID Series card MSTI Port Configuration: MSTI1 Normal Port3 Configuration - Path Cost Valid values are in the range 0 to 200000000. Setting 0 means Auto path c…
1.3.6.1.4.1.4756.20.501.20.1.1119ColumnnidMSTI4Port3PriorityRemoteAread-writecurrentNID Series card MSTI Port Configuration: MSTI4 Normal Port3 Configuration - Priority
1.3.6.1.4.1.4756.20.501.20.1.1120ColumnnidMSTI4Port4PathCostRemoteAread-writecurrentNID Series card MSTI Port Configuration: MSTI4 Normal Port4 Configuration - Path Cost Valid values are in the range 0 to 200000000. Setting 0 means Auto path c…
1.3.6.1.4.1.4756.20.501.20.1.1121ColumnnidMSTI4Port4PriorityRemoteAread-writecurrentNID Series card MSTI Port Configuration: MSTI4 Normal Port4 Configuration - Priority
1.3.6.1.4.1.4756.20.501.20.1.1122ColumnnidMSTI4Port5PathCostRemoteAread-writecurrentNID Series card MSTI Port Configuration: MSTI4 Normal Port5 Configuration - Path Cost Valid values are in the range 0 to 200000000. Setting 0 means Auto path c…
1.3.6.1.4.1.4756.20.501.20.1.1123ColumnnidMSTI4Port5PriorityRemoteAread-writecurrentNID Series card MSTI Port Configuration: MSTI4 Normal Port5 Configuration - Priority
1.3.6.1.4.1.4756.20.501.20.1.1124ColumnnidMSTI4Port6PathCostRemoteAread-writecurrentNID Series card MSTI Port Configuration: MSTI4 Normal Port4 Configuration - Path Cost Valid values are in the range 0 to 200000000. Setting 0 means Auto path c…
1.3.6.1.4.1.4756.20.501.20.1.1125ColumnnidMSTI4Port6PriorityRemoteAread-writecurrentNID Series card MSTI Port Configuration: MSTI4 Normal Port6 Configuration - Priority
1.3.6.1.4.1.4756.20.501.20.1.1126ColumnnidMSTI4Port7PathCostRemoteAread-writecurrentNID Series card MSTI Port Configuration: MSTI4 Normal Port7 Configuration - Path Cost Valid values are in the range 0 to 200000000. Setting 0 means Auto path c…
1.3.6.1.4.1.4756.20.501.20.1.1127ColumnnidMSTI4Port7PriorityRemoteAread-writecurrentNID Series card MSTI Port Configuration: MSTI4 Normal Port7 Configuration - Priority
1.3.6.1.4.1.4756.20.501.20.1.1128ColumnnidMSTI4Port8PathCostRemoteAread-writecurrentNID Series card MSTI Port Configuration: MSTI4 Normal Port8 Configuration - Path Cost Valid values are in the range 0 to 200000000. Setting 0 means Auto path c…
1.3.6.1.4.1.4756.20.501.20.1.1129ColumnnidMSTI4Port8PriorityRemoteAread-writecurrentNID Series card MSTI Port Configuration: MSTI4 Normal Port8 Configuration - Priority
1.3.6.1.4.1.4756.20.501.20.1.1130ColumnnidMSTI5AggregatedPathCostRemoteAread-writecurrentNID Series card MSTI Port Configuration: MSTI5 Aggregated Ports Configuration - Path Cost Valid values are in the range 0 to 200000000. Setting 0 means Auto pa…
1.3.6.1.4.1.4756.20.501.20.1.1131ColumnnidMSTI5AggregatedPriorityRemoteAread-writecurrentNID Series card MSTI Port Configuration: MSTI5 Aggregated Ports Configuration - Priority
1.3.6.1.4.1.4756.20.501.20.1.1132ColumnnidMSTI5Port1PathCostRemoteAread-writecurrentNID Series card MSTI Port Configuration: MSTI5 Normal Port1 Configuration - Path Cost Valid values are in the range 0 to 200000000. Setting 0 means Auto path c…
1.3.6.1.4.1.4756.20.501.20.1.1133ColumnnidMSTI5Port1PriorityRemoteAread-writecurrentNID Series card MSTI Port Configuration: MSTI5 Normal Port1 Configuration - Priority
1.3.6.1.4.1.4756.20.501.20.1.1134ColumnnidMSTI5Port2PathCostRemoteAread-writecurrentNID Series card MSTI Port Configuration: MSTI5 Normal Port2 Configuration - Path Cost Valid values are in the range 0 to 200000000. Setting 0 means Auto path c…
1.3.6.1.4.1.4756.20.501.20.1.1135ColumnnidMSTI5Port2PriorityRemoteAread-writecurrentNID Series card MSTI Port Configuration: MSTI5 Normal Port2 Configuration - Priority
1.3.6.1.4.1.4756.20.501.20.1.1136ColumnnidMSTI5Port3PathCostRemoteAread-writecurrentNID Series card MSTI Port Configuration: MSTI5 Normal Port3 Configuration - Path Cost Valid values are in the range 0 to 200000000. Setting 0 means Auto path c…
1.3.6.1.4.1.4756.20.501.20.1.1137ColumnnidMSTI5Port3PriorityRemoteAread-writecurrentNID Series card MSTI Port Configuration: MSTI5 Normal Port3 Configuration - Priority
1.3.6.1.4.1.4756.20.501.20.1.1138ColumnnidMSTI5Port4PathCostRemoteAread-writecurrentNID Series card MSTI Port Configuration: MSTI5 Normal Port4 Configuration - Path Cost Valid values are in the range 0 to 200000000. Setting 0 means Auto path c…
1.3.6.1.4.1.4756.20.501.20.1.1139ColumnnidMSTI5Port4PriorityRemoteAread-writecurrentNID Series card MSTI Port Configuration: MSTI5 Normal Port4 Configuration - Priority
1.3.6.1.4.1.4756.20.501.20.1.1140ColumnnidMSTI5Port5PathCostRemoteAread-writecurrentNID Series card MSTI Port Configuration: MSTI5 Normal Port5 Configuration - Path Cost Valid values are in the range 0 to 200000000. Setting 0 means Auto path c…
1.3.6.1.4.1.4756.20.501.20.1.1141ColumnnidMSTI5Port5PriorityRemoteAread-writecurrentNID Series card MSTI Port Configuration: MSTI5 Normal Port5 Configuration - Priority
1.3.6.1.4.1.4756.20.501.20.1.1142ColumnnidMSTI5Port6PathCostRemoteAread-writecurrentNID Series card MSTI Port Configuration: MSTI5 Normal Port6 Configuration - Path Cost Valid values are in the range 0 to 200000000. Setting 0 means Auto path c…
1.3.6.1.4.1.4756.20.501.20.1.1143ColumnnidMSTI5Port6PriorityRemoteAread-writecurrentNID Series card MSTI Port Configuration: MSTI5 Normal Port6 Configuration - Priority
1.3.6.1.4.1.4756.20.501.20.1.1144ColumnnidMSTI5Port7PathCostRemoteAread-writecurrentNID Series card MSTI Port Configuration: MSTI5 Normal Port7 Configuration - Path Cost Valid values are in the range 0 to 200000000. Setting 0 means Auto path c…
1.3.6.1.4.1.4756.20.501.20.1.1145ColumnnidMSTI5Port7PriorityRemoteAread-writecurrentNID Series card MSTI Port Configuration: MSTI5 Normal Port7 Configuration - Priority
1.3.6.1.4.1.4756.20.501.20.1.1146ColumnnidMSTI5Port8PathCostRemoteAread-writecurrentNID Series card MSTI Port Configuration: MSTI5 Normal Port8 Configuration - Path Cost Valid values are in the range 0 to 200000000. Setting 0 means Auto path c…
1.3.6.1.4.1.4756.20.501.20.1.1147ColumnnidMSTI5Port8PriorityRemoteAread-writecurrentNID Series card MSTI Port Configuration: MSTI5 Normal Port8 Configuration - Priority
1.3.6.1.4.1.4756.20.501.20.1.1148ColumnnidMSTI6AggregatedPathCostRemoteAread-writecurrentNID Series card MSTI Port Configuration: MSTI6 Aggregated Ports Configuration - Path Cost Valid values are in the range 0 to 200000000. Setting 0 means Auto pa…
1.3.6.1.4.1.4756.20.501.20.1.1149ColumnnidMSTI6AggregatedPriorityRemoteAread-writecurrentNID Series card MSTI Port Configuration: MSTI6 Aggregated Ports Configuration - Priority
1.3.6.1.4.1.4756.20.501.20.1.1150ColumnnidMSTI6Port1PathCostRemoteAread-writecurrentNID Series card MSTI Port Configuration: MSTI6 Normal Port1 Configuration - Path Cost Valid values are in the range 0 to 200000000. Setting 0 means Auto path c…
1.3.6.1.4.1.4756.20.501.20.1.1151ColumnnidMSTI6Port1PriorityRemoteAread-writecurrentNID Series card MSTI Port Configuration: MSTI6 Normal Port1 Configuration - Priority
1.3.6.1.4.1.4756.20.501.20.1.1152ColumnnidMSTI6Port2PathCostRemoteAread-writecurrentNID Series card MSTI Port Configuration: MSTI6 Normal Port2 Configuration - Path Cost Valid values are in the range 0 to 200000000. Setting 0 means Auto path c…
1.3.6.1.4.1.4756.20.501.20.1.1153ColumnnidMSTI6Port2PriorityRemoteAread-writecurrentNID Series card MSTI Port Configuration: MSTI6 Normal Port2 Configuration - Priority
1.3.6.1.4.1.4756.20.501.20.1.1154ColumnnidMSTI6Port3PathCostRemoteAread-writecurrentNID Series card MSTI Port Configuration: MSTI6 Normal Port3 Configuration - Path Cost Valid values are in the range 0 to 200000000. Setting 0 means Auto path c…
1.3.6.1.4.1.4756.20.501.20.1.1155ColumnnidMSTI6Port3PriorityRemoteAread-writecurrentNID Series card MSTI Port Configuration: MSTI6 Normal Port3 Configuration - Priority
1.3.6.1.4.1.4756.20.501.20.1.1156ColumnnidMSTI6Port4PathCostRemoteAread-writecurrentNID Series card MSTI Port Configuration: MSTI6 Normal Port4 Configuration - Path Cost Valid values are in the range 0 to 200000000. Setting 0 means Auto path c…
1.3.6.1.4.1.4756.20.501.20.1.1157ColumnnidMSTI6Port4PriorityRemoteAread-writecurrentNID Series card MSTI Port Configuration: MSTI6 Normal Port4 Configuration - Priority
1.3.6.1.4.1.4756.20.501.20.1.1158ColumnnidMSTI6Port5PathCostRemoteAread-writecurrentNID Series card MSTI Port Configuration: MSTI6 Normal Port5 Configuration - Path Cost Valid values are in the range 0 to 200000000. Setting 0 means Auto path c…
1.3.6.1.4.1.4756.20.501.20.1.1159ColumnnidMSTI6Port5PriorityRemoteAread-writecurrentNID Series card MSTI Port Configuration: MSTI6 Normal Port6 Configuration - Priority
1.3.6.1.4.1.4756.20.501.20.1.1160ColumnnidMSTI6Port6PathCostRemoteAread-writecurrentNID Series card MSTI Port Configuration: MSTI6 Normal Port6 Configuration - Path Cost Valid values are in the range 0 to 200000000. Setting 0 means Auto path c…
1.3.6.1.4.1.4756.20.501.20.1.1161ColumnnidMSTI6Port6PriorityRemoteAread-writecurrentNID Series card MSTI Port Configuration: MSTI6 Normal Port6 Configuration - Priority
1.3.6.1.4.1.4756.20.501.20.1.1162ColumnnidMSTI6Port7PathCostRemoteAread-writecurrentNID Series card MSTI Port Configuration: MSTI6 Normal Port7 Configuration - Path Cost Valid values are in the range 0 to 200000000. Setting 0 means Auto path c…
1.3.6.1.4.1.4756.20.501.20.1.1163ColumnnidMSTI6Port7PriorityRemoteAread-writecurrentNID Series card MSTI Port Configuration: MSTI6 Normal Port6 Configuration - Priority
1.3.6.1.4.1.4756.20.501.20.1.1164ColumnnidMSTI6Port8PathCostRemoteAread-writecurrentNID Series card MSTI Port Configuration: MSTI6 Normal Port8 Configuration - Path Cost Valid values are in the range 0 to 200000000. Setting 0 means Auto path c…
1.3.6.1.4.1.4756.20.501.20.1.1165ColumnnidMSTI6Port8PriorityRemoteAread-writecurrentNID Series card MSTI Port Configuration: MSTI6 Normal Port8 Configuration - Priority
1.3.6.1.4.1.4756.20.501.20.1.1166ColumnnidMSTI7AggregatedPathCostRemoteAread-writecurrentNID Series card MSTI Port Configuration: MSTI7 Aggregated Ports Configuration - Path Cost Valid values are in the range 0 to 200000000. Setting 0 means Auto pa…
1.3.6.1.4.1.4756.20.501.20.1.1167ColumnnidMSTI7AggregatedPriorityRemoteAread-writecurrentNID Series card MSTI Port Configuration: MSTI7 Aggregated Ports Configuration - Priority
1.3.6.1.4.1.4756.20.501.20.1.1168ColumnnidMSTI7Port1PathCostRemoteAread-writecurrentNID Series card MSTI Port Configuration: MSTI1 Normal Port1 Configuration - Path Cost Valid values are in the range 0 to 200000000. Setting 0 means Auto path c…
1.3.6.1.4.1.4756.20.501.20.1.1169ColumnnidMSTI7Port1PriorityRemoteAread-writecurrentNID Series card MSTI Port Configuration: MSTI1 Normal Port1 Configuration - Priority
1.3.6.1.4.1.4756.20.501.20.1.1170ColumnnidMSTI7Port2PathCostRemoteAread-writecurrentNID Series card MSTI Port Configuration: MSTI7 Normal Port2 Configuration - Path Cost Valid values are in the range 0 to 200000000. Setting 0 means Auto path c…
1.3.6.1.4.1.4756.20.501.20.1.1171ColumnnidMSTI7Port2PriorityRemoteAread-writecurrentNID Series card MSTI Port Configuration: MSTI7 Normal Port2 Configuration - Priority
1.3.6.1.4.1.4756.20.501.20.1.1172ColumnnidMSTI7Port3PathCostRemoteAread-writecurrentNID Series card MSTI Port Configuration: MSTI7 Normal Port3 Configuration - Path Cost Valid values are in the range 0 to 200000000. Setting 0 means Auto path c…
1.3.6.1.4.1.4756.20.501.20.1.1173ColumnnidMSTI7Port3PriorityRemoteAread-writecurrentNID Series card MSTI Port Configuration: MSTI7 Normal Port3 Configuration - Priority
1.3.6.1.4.1.4756.20.501.20.1.1174ColumnnidMSTI7Port4PathCostRemoteAread-writecurrentNID Series card MSTI Port Configuration: MSTI7 Normal Port4 Configuration - Path Cost Valid values are in the range 0 to 200000000. Setting 0 means Auto path c…
1.3.6.1.4.1.4756.20.501.20.1.1175ColumnnidMSTI7Port4PriorityRemoteAread-writecurrentNID Series card MSTI Port Configuration: MSTI7 Normal Port4 Configuration - Priority
1.3.6.1.4.1.4756.20.501.20.1.1176ColumnnidMSTI7Port5PathCostRemoteAread-writecurrentNID Series card MSTI Port Configuration: MSTI7 Normal Port5 Configuration - Path Cost Valid values are in the range 0 to 200000000. Setting 0 means Auto path c…
1.3.6.1.4.1.4756.20.501.20.1.1177ColumnnidMSTI7Port5PriorityRemoteAread-writecurrentNID Series card MSTI Port Configuration: MSTI7 Normal Port5 Configuration - Priority
1.3.6.1.4.1.4756.20.501.20.1.1178ColumnnidMSTI7Port6PathCostRemoteAread-writecurrentNID Series card MSTI Port Configuration: MSTI7 Normal Port6 Configuration - Path Cost Valid values are in the range 0 to 200000000. Setting 0 means Auto path c…
1.3.6.1.4.1.4756.20.501.20.1.1179ColumnnidMSTI7Port6PriorityRemoteAread-writecurrentNID Series card MSTI Port Configuration: MSTI7 Normal Port6 Configuration - Priority
1.3.6.1.4.1.4756.20.501.20.1.1180ColumnnidMSTI7Port7PathCostRemoteAread-writecurrentNID Series card MSTI Port Configuration: MSTI7 Normal Port7 Configuration - Path Cost Valid values are in the range 0 to 200000000. Setting 0 means Auto path c…
1.3.6.1.4.1.4756.20.501.20.1.1181ColumnnidMSTI7Port7PriorityRemoteAread-writecurrentNID Series card MSTI Port Configuration: MSTI7 Normal Port7 Configuration - Priority
1.3.6.1.4.1.4756.20.501.20.1.1182ColumnnidMSTI7Port8PathCostRemoteAread-writecurrentNID Series card MSTI Port Configuration: MSTI7 Normal Port8 Configuration - Path Cost Valid values are in the range 0 to 200000000. Setting 0 means Auto path c…
1.3.6.1.4.1.4756.20.501.20.1.1183ColumnnidMSTI7Port8PriorityRemoteAread-writecurrentNID Series card MSTI Port Configuration: MSTI7 Normal Port8 Configuration - Priority
1.3.6.1.4.1.4756.20.501.20.1.1184ColumnnidMSTI8AggregatedPathCostRemoteAread-writecurrentNID Series card MSTI Port Configuration: MSTI8 Aggregated Ports Configuration - Path Cost Valid values are in the range 0 to 200000000. Setting 0 means Auto pa…
1.3.6.1.4.1.4756.20.501.20.1.1185ColumnnidMSTI8AggregatedPriorityRemoteAread-writecurrentNID Series card MSTI Port Configuration: MSTI7 Aggregated Ports Configuration - Priority
1.3.6.1.4.1.4756.20.501.20.1.1186ColumnnidMSTI8Port1PathCostRemoteAread-writecurrentNID Series card MSTI Port Configuration: MSTI8 Normal Port1 Configuration - Path Cost Valid values are in the range 0 to 200000000. Setting 0 means Auto path c…
1.3.6.1.4.1.4756.20.501.20.1.1187ColumnnidMSTI8Port1PriorityRemoteAread-writecurrentNID Series card MSTI Port Configuration: MSTI8 Normal Port1 Configuration - Priority
1.3.6.1.4.1.4756.20.501.20.1.1188ColumnnidMSTI8Port2PathCostRemoteAread-writecurrentNID Series card MSTI Port Configuration: MSTI8 Normal Port2 Configuration - Path Cost Valid values are in the range 0 to 200000000. Setting 0 means Auto path c…
1.3.6.1.4.1.4756.20.501.20.1.1189ColumnnidMSTI8Port2PriorityRemoteAread-writecurrentNID Series card MSTI Port Configuration: MSTI8 Normal Port2 Configuration - Priority
1.3.6.1.4.1.4756.20.501.20.1.1190ColumnnidMSTI8Port3PathCostRemoteAread-writecurrentNID Series card MSTI Port Configuration: MSTI8 Normal Port3 Configuration - Path Cost Valid values are in the range 0 to 200000000. Setting 0 means Auto path c…
1.3.6.1.4.1.4756.20.501.20.1.1191ColumnnidMSTI8Port3PriorityRemoteAread-writecurrentNID Series card MSTI Port Configuration: MSTI8 Normal Port3 Configuration - Priority
1.3.6.1.4.1.4756.20.501.20.1.1192ColumnnidMSTI8Port4PathCostRemoteAread-writecurrentNID Series card MSTI Port Configuration: MSTI8 Normal Port4 Configuration - Path Cost Valid values are in the range 0 to 200000000. Setting 0 means Auto path c…
1.3.6.1.4.1.4756.20.501.20.1.1193ColumnnidMSTI8Port4PriorityRemoteAread-writecurrentNID Series card MSTI Port Configuration: MSTI8 Normal Port4 Configuration - Priority
1.3.6.1.4.1.4756.20.501.20.1.1194ColumnnidMSTI8Port5PathCostRemoteAread-writecurrentNID Series card MSTI Port Configuration: MSTI8 Normal Port5 Configuration - Path Cost Valid values are in the range 0 to 200000000. Setting 0 means Auto path c…
1.3.6.1.4.1.4756.20.501.20.1.1195ColumnnidMSTI8Port5PriorityRemoteAread-writecurrentNID Series card MSTI Port Configuration: MSTI8 Normal Port5 Configuration - Priority
1.3.6.1.4.1.4756.20.501.20.1.1196ColumnnidMSTI8Port6PathCostRemoteAread-writecurrentNID Series card MSTI Port Configuration: MSTI8 Normal Port6 Configuration - Path Cost Valid values are in the range 0 to 200000000. Setting 0 means Auto path c…
1.3.6.1.4.1.4756.20.501.20.1.1197ColumnnidMSTI8Port6PriorityRemoteAread-writecurrentNID Series card MSTI Port Configuration: MSTI8 Normal Port6 Configuration - Priority
1.3.6.1.4.1.4756.20.501.20.1.1198ColumnnidMSTI8Port7PathCostRemoteAread-writecurrentNID Series card MSTI Port Configuration: MSTI8 Normal Port7 Configuration - Path Cost Valid values are in the range 0 to 200000000. Setting 0 means Auto path c…
1.3.6.1.4.1.4756.20.501.20.1.1199ColumnnidMSTI8Port7PriorityRemoteAread-writecurrentNID Series card MSTI Port Configuration: MSTI8 Normal Port7 Configuration - Priority
1.3.6.1.4.1.4756.20.501.20.1.1200ColumnnidMSTI8Port8PathCostRemoteAread-writecurrentNID Series card MSTI Port Configuration: MSTI7 Normal Port8 Configuration - Path Cost Valid values are in the range 0 to 200000000. Setting 0 means Auto path c…
1.3.6.1.4.1.4756.20.501.20.1.1201ColumnnidMSTI8Port8PriorityRemoteAread-writecurrentNID Series card MSTI Port Configuration: MSTI8 Normal Port8 Configuration - Priority
1.3.6.1.4.1.4756.20.501.20.1.1202ColumnnidMSTI9AggregatedPathCostRemoteAread-writecurrentNID Series card MSTI Port Configuration: MSTI9 Aggregated Ports Configuration - Path Cost Valid values are in the range 0 to 200000000. Setting 0 means Auto pa…
1.3.6.1.4.1.4756.20.501.20.1.1203ColumnnidMSTI9AggregatedPriorityRemoteAread-writecurrentNID Series card MSTI Port Configuration: MSTI9 Aggregated Ports Configuration - Priority
1.3.6.1.4.1.4756.20.501.20.1.1204ColumnnidMSTI9Port1PathCostRemoteAread-writecurrentNID Series card MSTI Port Configuration: MSTI9 Normal Port1 Configuration - Path Cost Valid values are in the range 0 to 200000000. Setting 0 means Auto path c…
1.3.6.1.4.1.4756.20.501.20.1.1205ColumnnidMSTI9Port1PriorityRemoteAread-writecurrentNID Series card MSTI Port Configuration: MSTI9 Normal Port1 Configuration - Priority
1.3.6.1.4.1.4756.20.501.20.1.1206ColumnnidMSTI9Port2PathCostRemoteAread-writecurrentNID Series card MSTI Port Configuration: MSTI9 Normal Port2 Configuration - Path Cost Valid values are in the range 0 to 200000000. Setting 0 means Auto path c…
1.3.6.1.4.1.4756.20.501.20.1.1207ColumnnidMSTI9Port2PriorityRemoteAread-writecurrentNID Series card MSTI Port Configuration: MSTI8 Normal Port2 Configuration - Priority
1.3.6.1.4.1.4756.20.501.20.1.1208ColumnnidMSTI9Port3PathCostRemoteAread-writecurrentNID Series card MSTI Port Configuration: MSTI8 Normal Port3 Configuration - Path Cost Valid values are in the range 0 to 200000000. Setting 0 means Auto path c…
1.3.6.1.4.1.4756.20.501.20.1.1209ColumnnidMSTI9Port3PriorityRemoteAread-writecurrentNID Series card MSTI Port Configuration: MSTI9 Normal Port3 Configuration - Priority
1.3.6.1.4.1.4756.20.501.20.1.1210ColumnnidMSTI9Port4PathCostRemoteAread-writecurrentNID Series card MSTI Port Configuration: MSTI9 Normal Port4 Configuration - Path Cost Valid values are in the range 0 to 200000000. Setting 0 means Auto path c…
1.3.6.1.4.1.4756.20.501.20.1.1211ColumnnidMSTI9Port4PriorityRemoteAread-writecurrentNID Series card MSTI Port Configuration: MSTI9 Normal Port4 Configuration - Priority
1.3.6.1.4.1.4756.20.501.20.1.1212ColumnnidMSTI9Port5PathCostRemoteAread-writecurrentNID Series card MSTI Port Configuration: MSTI9 Normal Port5 Configuration - Path Cost Valid values are in the range 0 to 200000000. Setting 0 means Auto path c…
1.3.6.1.4.1.4756.20.501.20.1.1213ColumnnidMSTI9Port5PriorityRemoteAread-writecurrentNID Series card MSTI Port Configuration: MSTI9 Normal Port5 Configuration - Priority
1.3.6.1.4.1.4756.20.501.20.1.1214ColumnnidMSTI9Port6PathCostRemoteAread-writecurrentNID Series card MSTI Port Configuration: MSTI9 Normal Port6 Configuration - Path Cost Valid values are in the range 0 to 200000000. Setting 0 means Auto path c…
1.3.6.1.4.1.4756.20.501.20.1.1215ColumnnidMSTI9Port6PriorityRemoteAread-writecurrentNID Series card MSTI Port Configuration: MSTI9 Normal Port6 Configuration - Priority
1.3.6.1.4.1.4756.20.501.20.1.1216ColumnnidMSTI9Port7PathCostRemoteAread-writecurrentNID Series card MSTI Port Configuration: MSTI9 Normal Port7 Configuration - Path Cost Valid values are in the range 0 to 200000000. Setting 0 means Auto path c…
1.3.6.1.4.1.4756.20.501.20.1.1217ColumnnidMSTI9Port7PriorityRemoteAread-writecurrentNID Series card MSTI Port Configuration: MSTI9 Normal Port7 Configuration - Priority
1.3.6.1.4.1.4756.20.501.20.1.1218ColumnnidMSTI9Port8PathCostRemoteAread-writecurrentNID Series card MSTI Port Configuration: MSTI8 Normal Port8 Configuration - Path Cost Valid values are in the range 0 to 200000000. Setting 0 means Auto path c…
1.3.6.1.4.1.4756.20.501.20.1.1219ColumnnidMSTI9Port8PriorityRemoteAread-writecurrentNID Series card MSTI Port Configuration: MSTI9 Normal Port8 Configuration - Priority
1.3.6.1.4.1.4756.20.501.20.1.1220ColumnnidMSTI10AggregatedPathCostRemoteAread-writecurrentNID Series card MSTI Port Configuration: MSTI10 Aggregated Ports Configuration - Path Cost Valid values are in the range 0 to 200000000. Setting 0 means Auto p…
1.3.6.1.4.1.4756.20.501.20.1.1221ColumnnidMSTI10AggregatedPriorityRemoteAread-writecurrentNID Series card MSTI Port Configuration: MSTI10 Aggregated Ports Configuration - Priority
1.3.6.1.4.1.4756.20.501.20.1.1222ColumnnidMSTI10Port1PathCostRemoteAread-writecurrentNID Series card MSTI Port Configuration: MSTI10 Normal Port1 Configuration - Path Cost Valid values are in the range 0 to 200000000. Setting 0 means Auto path …
1.3.6.1.4.1.4756.20.501.20.1.1223ColumnnidMSTI10Port1PriorityRemoteAread-writecurrentNID Series card MSTI Port Configuration: MSTI10 Normal Port1 Configuration - Priority
1.3.6.1.4.1.4756.20.501.20.1.1224ColumnnidMSTI10Port2PathCostRemoteAread-writecurrentNID Series card MSTI Port Configuration: MSTI10 Normal Port2 Configuration - Path Cost Valid values are in the range 0 to 200000000. Setting 0 means Auto path …
1.3.6.1.4.1.4756.20.501.20.1.1225ColumnnidMSTI10Port2PriorityRemoteAread-writecurrentNID Series card MSTI Port Configuration: MSTI8 Normal Port2 Configuration - Priority
1.3.6.1.4.1.4756.20.501.20.1.1226ColumnnidMSTI10Port3PathCostRemoteAread-writecurrentNID Series card MSTI Port Configuration: MSTI8 Normal Port3 Configuration - Path Cost Valid values are in the range 0 to 200000000. Setting 0 means Auto path c…
1.3.6.1.4.1.4756.20.501.20.1.1227ColumnnidMSTI10Port3PriorityRemoteAread-writecurrentNID Series card MSTI Port Configuration: MSTI10 Normal Port3 Configuration - Priority
1.3.6.1.4.1.4756.20.501.20.1.1228ColumnnidMSTI10Port4PathCostRemoteAread-writecurrentNID Series card MSTI Port Configuration: MSTI10 Normal Port4 Configuration - Path Cost Valid values are in the range 0 to 200000000. Setting 0 means Auto path …
1.3.6.1.4.1.4756.20.501.20.1.1229ColumnnidMSTI10Port4PriorityRemoteAread-writecurrentNID Series card MSTI Port Configuration: MSTI10 Normal Port4 Configuration - Priority
1.3.6.1.4.1.4756.20.501.20.1.1230ColumnnidMSTI10Port5PathCostRemoteAread-writecurrentNID Series card MSTI Port Configuration: MSTI10 Normal Port5 Configuration - Path Cost Valid values are in the range 0 to 200000000. Setting 0 means Auto path …
1.3.6.1.4.1.4756.20.501.20.1.1231ColumnnidMSTI10Port5PriorityRemoteAread-writecurrentNID Series card MSTI Port Configuration: MSTI10 Normal Port5 Configuration - Priority
1.3.6.1.4.1.4756.20.501.20.1.1232ColumnnidMSTI10Port6PathCostRemoteAread-writecurrentNID Series card MSTI Port Configuration: MSTI10 Normal Port6 Configuration - Path Cost Valid values are in the range 0 to 200000000. Setting 0 means Auto path …
1.3.6.1.4.1.4756.20.501.20.1.1233ColumnnidMSTI10Port6PriorityRemoteAread-writecurrentNID Series card MSTI Port Configuration: MSTI10 Normal Port6 Configuration - Priority
1.3.6.1.4.1.4756.20.501.20.1.1234ColumnnidMSTI10Port7PathCostRemoteAread-writecurrentNID Series card MSTI Port Configuration: MSTI10 Normal Port7 Configuration - Path Cost Valid values are in the range 0 to 200000000. Setting 0 means Auto path …
1.3.6.1.4.1.4756.20.501.20.1.1235ColumnnidMSTI10Port7PriorityRemoteAread-writecurrentNID Series card MSTI Port Configuration: MSTI10 Normal Port7 Configuration - Priority
1.3.6.1.4.1.4756.20.501.20.1.1236ColumnnidMSTI10Port8PathCostRemoteAread-writecurrentNID Series card MSTI Port Configuration: MSTI8 Normal Port8 Configuration - Path Cost Valid values are in the range 0 to 200000000. Setting 0 means Auto path c…
1.3.6.1.4.1.4756.20.501.20.1.1237ColumnnidMSTI10Port8PriorityRemoteAread-writecurrentNID Series card MSTI Port Configuration: MSTI10 Normal Port8 Configuration - Priority
1.3.6.1.4.1.4756.20.501.20.1.1238ColumnnidMSTI11AggregatedPathCostRemoteAread-writecurrentNID Series card MSTI Port Configuration: MSTI11 Aggregated Ports Configuration - Path Cost Valid values are in the range 0 to 200000000. Setting 0 means Auto p…
1.3.6.1.4.1.4756.20.501.20.1.1239ColumnnidMSTI11AggregatedPriorityRemoteAread-writecurrentNID Series card MSTI Port Configuration: MSTI11 Aggregated Ports Configuration - Priority
1.3.6.1.4.1.4756.20.501.20.1.1240ColumnnidMSTI11Port1PathCostRemoteAread-writecurrentNID Series card MSTI Port Configuration: MSTI11 Normal Port1 Configuration - Path Cost Valid values are in the range 0 to 200000000. Setting 0 means Auto path …
1.3.6.1.4.1.4756.20.501.20.1.1241ColumnnidMSTI11Port1PriorityRemoteAread-writecurrentNID Series card MSTI Port Configuration: MSTI11 Normal Port1 Configuration - Priority
1.3.6.1.4.1.4756.20.501.20.1.1242ColumnnidMSTI11Port2PathCostRemoteAread-writecurrentNID Series card MSTI Port Configuration: MSTI11 Normal Port2 Configuration - Path Cost Valid values are in the range 0 to 200000000. Setting 0 means Auto path …
1.3.6.1.4.1.4756.20.501.20.1.1243ColumnnidMSTI11Port2PriorityRemoteAread-writecurrentNID Series card MSTI Port Configuration: MSTI8 Normal Port2 Configuration - Priority
1.3.6.1.4.1.4756.20.501.20.1.1244ColumnnidMSTI11Port3PathCostRemoteAread-writecurrentNID Series card MSTI Port Configuration: MSTI8 Normal Port3 Configuration - Path Cost Valid values are in the range 0 to 200000000. Setting 0 means Auto path c…
1.3.6.1.4.1.4756.20.501.20.1.1245ColumnnidMSTI11Port3PriorityRemoteAread-writecurrentNID Series card MSTI Port Configuration: MSTI11 Normal Port3 Configuration - Priority
1.3.6.1.4.1.4756.20.501.20.1.1246ColumnnidMSTI11Port4PathCostRemoteAread-writecurrentNID Series card MSTI Port Configuration: MSTI11 Normal Port4 Configuration - Path Cost Valid values are in the range 0 to 200000000. Setting 0 means Auto path …
1.3.6.1.4.1.4756.20.501.20.1.1247ColumnnidMSTI11Port4PriorityRemoteAread-writecurrentNID Series card MSTI Port Configuration: MSTI11 Normal Port4 Configuration - Priority
1.3.6.1.4.1.4756.20.501.20.1.1248ColumnnidMSTI11Port5PathCostRemoteAread-writecurrentNID Series card MSTI Port Configuration: MSTI11 Normal Port5 Configuration - Path Cost Valid values are in the range 0 to 200000000. Setting 0 means Auto path …
1.3.6.1.4.1.4756.20.501.20.1.1249ColumnnidMSTI11Port5PriorityRemoteAread-writecurrentNID Series card MSTI Port Configuration: MSTI11 Normal Port5 Configuration - Priority
1.3.6.1.4.1.4756.20.501.20.1.1250ColumnnidMSTI11Port6PathCostRemoteAread-writecurrentNID Series card MSTI Port Configuration: MSTI11 Normal Port6 Configuration - Path Cost Valid values are in the range 0 to 200000000. Setting 0 means Auto path …
1.3.6.1.4.1.4756.20.501.20.1.1251ColumnnidMSTI11Port6PriorityRemoteAread-writecurrentNID Series card MSTI Port Configuration: MSTI11 Normal Port6 Configuration - Priority
1.3.6.1.4.1.4756.20.501.20.1.1252ColumnnidMSTI11Port7PathCostRemoteAread-writecurrentNID Series card MSTI Port Configuration: MSTI11 Normal Port7 Configuration - Path Cost Valid values are in the range 0 to 200000000. Setting 0 means Auto path …
1.3.6.1.4.1.4756.20.501.20.1.1253ColumnnidMSTI11Port7PriorityRemoteAread-writecurrentNID Series card MSTI Port Configuration: MSTI11 Normal Port7 Configuration - Priority
1.3.6.1.4.1.4756.20.501.20.1.1254ColumnnidMSTI11Port8PathCostRemoteAread-writecurrentNID Series card MSTI Port Configuration: MSTI8 Normal Port8 Configuration - Path Cost Valid values are in the range 0 to 200000000. Setting 0 means Auto path c…
1.3.6.1.4.1.4756.20.501.20.1.1255ColumnnidMSTI11Port8PriorityRemoteAread-writecurrentNID Series card MSTI Port Configuration: MSTI11 Normal Port8 Configuration - Priority
1.3.6.1.4.1.4756.20.501.20.1.1256ColumnnidMSTI12AggregatedPathCostRemoteAread-writecurrentNID Series card MSTI Port Configuration: MSTI12 Aggregated Ports Configuration - Path Cost Valid values are in the range 0 to 200000000. Setting 0 means Auto p…
1.3.6.1.4.1.4756.20.501.20.1.1257ColumnnidMSTI12AggregatedPriorityRemoteAread-writecurrentNID Series card MSTI Port Configuration: MSTI12 Aggregated Ports Configuration - Priority
1.3.6.1.4.1.4756.20.501.20.1.1258ColumnnidMSTI12Port1PathCostRemoteAread-writecurrentNID Series card MSTI Port Configuration: MSTI12 Normal Port1 Configuration - Path Cost Valid values are in the range 0 to 200000000. Setting 0 means Auto path …
1.3.6.1.4.1.4756.20.501.20.1.1259ColumnnidMSTI12Port1PriorityRemoteAread-writecurrentNID Series card MSTI Port Configuration: MSTI12 Normal Port1 Configuration - Priority
1.3.6.1.4.1.4756.20.501.20.1.1260ColumnnidMSTI12Port2PathCostRemoteAread-writecurrentNID Series card MSTI Port Configuration: MSTI12 Normal Port2 Configuration - Path Cost Valid values are in the range 0 to 200000000. Setting 0 means Auto path …
1.3.6.1.4.1.4756.20.501.20.1.1261ColumnnidMSTI12Port2PriorityRemoteAread-writecurrentNID Series card MSTI Port Configuration: MSTI8 Normal Port2 Configuration - Priority
1.3.6.1.4.1.4756.20.501.20.1.1262ColumnnidMSTI12Port3PathCostRemoteAread-writecurrentNID Series card MSTI Port Configuration: MSTI8 Normal Port3 Configuration - Path Cost Valid values are in the range 0 to 200000000. Setting 0 means Auto path c…
1.3.6.1.4.1.4756.20.501.20.1.1263ColumnnidMSTI12Port3PriorityRemoteAread-writecurrentNID Series card MSTI Port Configuration: MSTI12 Normal Port3 Configuration - Priority
1.3.6.1.4.1.4756.20.501.20.1.1264ColumnnidMSTI12Port4PathCostRemoteAread-writecurrentNID Series card MSTI Port Configuration: MSTI12 Normal Port4 Configuration - Path Cost Valid values are in the range 0 to 200000000. Setting 0 means Auto path …
1.3.6.1.4.1.4756.20.501.20.1.1265ColumnnidMSTI12Port4PriorityRemoteAread-writecurrentNID Series card MSTI Port Configuration: MSTI12 Normal Port4 Configuration - Priority
1.3.6.1.4.1.4756.20.501.20.1.1266ColumnnidMSTI12Port5PathCostRemoteAread-writecurrentNID Series card MSTI Port Configuration: MSTI12 Normal Port5 Configuration - Path Cost Valid values are in the range 0 to 200000000. Setting 0 means Auto path …
1.3.6.1.4.1.4756.20.501.20.1.1267ColumnnidMSTI12Port5PriorityRemoteAread-writecurrentNID Series card MSTI Port Configuration: MSTI12 Normal Port5 Configuration - Priority
1.3.6.1.4.1.4756.20.501.20.1.1268ColumnnidMSTI12Port6PathCostRemoteAread-writecurrentNID Series card MSTI Port Configuration: MSTI12 Normal Port6 Configuration - Path Cost Valid values are in the range 0 to 200000000. Setting 0 means Auto path …
1.3.6.1.4.1.4756.20.501.20.1.1269ColumnnidMSTI12Port6PriorityRemoteAread-writecurrentNID Series card MSTI Port Configuration: MSTI12 Normal Port6 Configuration - Priority
1.3.6.1.4.1.4756.20.501.20.1.1270ColumnnidMSTI12Port7PathCostRemoteAread-writecurrentNID Series card MSTI Port Configuration: MSTI12 Normal Port7 Configuration - Path Cost Valid values are in the range 0 to 200000000. Setting 0 means Auto path …
1.3.6.1.4.1.4756.20.501.20.1.1271ColumnnidMSTI12Port7PriorityRemoteAread-writecurrentNID Series card MSTI Port Configuration: MSTI12 Normal Port7 Configuration - Priority
1.3.6.1.4.1.4756.20.501.20.1.1272ColumnnidMSTI12Port8PathCostRemoteAread-writecurrentNID Series card MSTI Port Configuration: MSTI8 Normal Port8 Configuration - Path Cost Valid values are in the range 0 to 200000000. Setting 0 means Auto path c…
1.3.6.1.4.1.4756.20.501.20.1.1273ColumnnidMSTI12Port8PriorityRemoteAread-writecurrentNID Series card MSTI Port Configuration: MSTI12 Normal Port8 Configuration - Priority
1.3.6.1.4.1.4756.20.501.20.1.1274ColumnnidMSTI13AggregatedPathCostRemoteAread-writecurrentNID Series card MSTI Port Configuration: MSTI13 Aggregated Ports Configuration - Path Cost Valid values are in the range 0 to 200000000. Setting 0 means Auto p…
1.3.6.1.4.1.4756.20.501.20.1.1275ColumnnidMSTI13AggregatedPriorityRemoteAread-writecurrentNID Series card MSTI Port Configuration: MSTI13 Aggregated Ports Configuration - Priority
1.3.6.1.4.1.4756.20.501.20.1.1276ColumnnidMSTI13Port1PathCostRemoteAread-writecurrentNID Series card MSTI Port Configuration: MSTI13 Normal Port1 Configuration - Path Cost Valid values are in the range 0 to 200000000. Setting 0 means Auto path …
1.3.6.1.4.1.4756.20.501.20.1.1277ColumnnidMSTI13Port1PriorityRemoteAread-writecurrentNID Series card MSTI Port Configuration: MSTI13 Normal Port1 Configuration - Priority
1.3.6.1.4.1.4756.20.501.20.1.1278ColumnnidMSTI13Port2PathCostRemoteAread-writecurrentNID Series card MSTI Port Configuration: MSTI13 Normal Port2 Configuration - Path Cost Valid values are in the range 0 to 200000000. Setting 0 means Auto path …
1.3.6.1.4.1.4756.20.501.20.1.1279ColumnnidMSTI13Port2PriorityRemoteAread-writecurrentNID Series card MSTI Port Configuration: MSTI8 Normal Port2 Configuration - Priority
1.3.6.1.4.1.4756.20.501.20.1.1280ColumnnidMSTI13Port3PathCostRemoteAread-writecurrentNID Series card MSTI Port Configuration: MSTI8 Normal Port3 Configuration - Path Cost Valid values are in the range 0 to 200000000. Setting 0 means Auto path c…
1.3.6.1.4.1.4756.20.501.20.1.1281ColumnnidMSTI13Port3PriorityRemoteAread-writecurrentNID Series card MSTI Port Configuration: MSTI13 Normal Port3 Configuration - Priority
1.3.6.1.4.1.4756.20.501.20.1.1282ColumnnidMSTI13Port4PathCostRemoteAread-writecurrentNID Series card MSTI Port Configuration: MSTI13 Normal Port4 Configuration - Path Cost Valid values are in the range 0 to 200000000. Setting 0 means Auto path …
1.3.6.1.4.1.4756.20.501.20.1.1283ColumnnidMSTI13Port4PriorityRemoteAread-writecurrentNID Series card MSTI Port Configuration: MSTI13 Normal Port4 Configuration - Priority
1.3.6.1.4.1.4756.20.501.20.1.1284ColumnnidMSTI13Port5PathCostRemoteAread-writecurrentNID Series card MSTI Port Configuration: MSTI13 Normal Port5 Configuration - Path Cost Valid values are in the range 0 to 200000000. Setting 0 means Auto path …
1.3.6.1.4.1.4756.20.501.20.1.1285ColumnnidMSTI13Port5PriorityRemoteAread-writecurrentNID Series card MSTI Port Configuration: MSTI13 Normal Port5 Configuration - Priority
1.3.6.1.4.1.4756.20.501.20.1.1286ColumnnidMSTI13Port6PathCostRemoteAread-writecurrentNID Series card MSTI Port Configuration: MSTI13 Normal Port6 Configuration - Path Cost Valid values are in the range 0 to 200000000. Setting 0 means Auto path …
1.3.6.1.4.1.4756.20.501.20.1.1287ColumnnidMSTI13Port6PriorityRemoteAread-writecurrentNID Series card MSTI Port Configuration: MSTI13 Normal Port6 Configuration - Priority
1.3.6.1.4.1.4756.20.501.20.1.1288ColumnnidMSTI13Port7PathCostRemoteAread-writecurrentNID Series card MSTI Port Configuration: MSTI13 Normal Port7 Configuration - Path Cost Valid values are in the range 0 to 200000000. Setting 0 means Auto path …
1.3.6.1.4.1.4756.20.501.20.1.1289ColumnnidMSTI13Port7PriorityRemoteAread-writecurrentNID Series card MSTI Port Configuration: MSTI13 Normal Port7 Configuration - Priority
1.3.6.1.4.1.4756.20.501.20.1.1290ColumnnidMSTI13Port8PathCostRemoteAread-writecurrentNID Series card MSTI Port Configuration: MSTI8 Normal Port8 Configuration - Path Cost Valid values are in the range 0 to 200000000. Setting 0 means Auto path c…
1.3.6.1.4.1.4756.20.501.20.1.1291ColumnnidMSTI13Port8PriorityRemoteAread-writecurrentNID Series card MSTI Port Configuration: MSTI13 Normal Port8 Configuration - Priority
1.3.6.1.4.1.4756.20.501.20.1.1292ColumnnidMSTI14AggregatedPathCostRemoteAread-writecurrentNID Series card MSTI Port Configuration: MSTI14 Aggregated Ports Configuration - Path Cost Valid values are in the range 0 to 200000000. Setting 0 means Auto p…
1.3.6.1.4.1.4756.20.501.20.1.1293ColumnnidMSTI14AggregatedPriorityRemoteAread-writecurrentNID Series card MSTI Port Configuration: MSTI14 Aggregated Ports Configuration - Priority
1.3.6.1.4.1.4756.20.501.20.1.1294ColumnnidMSTI14Port1PathCostRemoteAread-writecurrentNID Series card MSTI Port Configuration: MSTI14 Normal Port1 Configuration - Path Cost Valid values are in the range 0 to 200000000. Setting 0 means Auto path …
1.3.6.1.4.1.4756.20.501.20.1.1295ColumnnidMSTI14Port1PriorityRemoteAread-writecurrentNID Series card MSTI Port Configuration: MSTI14 Normal Port1 Configuration - Priority
1.3.6.1.4.1.4756.20.501.20.1.1296ColumnnidMSTI14Port2PathCostRemoteAread-writecurrentNID Series card MSTI Port Configuration: MSTI14 Normal Port2 Configuration - Path Cost Valid values are in the range 0 to 200000000. Setting 0 means Auto path …
1.3.6.1.4.1.4756.20.501.20.1.1297ColumnnidMSTI14Port2PriorityRemoteAread-writecurrentNID Series card MSTI Port Configuration: MSTI8 Normal Port2 Configuration - Priority
1.3.6.1.4.1.4756.20.501.20.1.1298ColumnnidMSTI14Port3PathCostRemoteAread-writecurrentNID Series card MSTI Port Configuration: MSTI8 Normal Port3 Configuration - Path Cost Valid values are in the range 0 to 200000000. Setting 0 means Auto path c…
1.3.6.1.4.1.4756.20.501.20.1.1299ColumnnidMSTI14Port3PriorityRemoteAread-writecurrentNID Series card MSTI Port Configuration: MSTI14 Normal Port3 Configuration - Priority
1.3.6.1.4.1.4756.20.501.20.1.1300ColumnnidMSTI14Port4PathCostRemoteAread-writecurrentNID Series card MSTI Port Configuration: MSTI14 Normal Port4 Configuration - Path Cost Valid values are in the range 0 to 200000000. Setting 0 means Auto path …
1.3.6.1.4.1.4756.20.501.20.1.1301ColumnnidMSTI14Port4PriorityRemoteAread-writecurrentNID Series card MSTI Port Configuration: MSTI14 Normal Port4 Configuration - Priority
1.3.6.1.4.1.4756.20.501.20.1.1302ColumnnidMSTI14Port5PathCostRemoteAread-writecurrentNID Series card MSTI Port Configuration: MSTI14 Normal Port5 Configuration - Path Cost Valid values are in the range 0 to 200000000. Setting 0 means Auto path …
1.3.6.1.4.1.4756.20.501.20.1.1303ColumnnidMSTI14Port5PriorityRemoteAread-writecurrentNID Series card MSTI Port Configuration: MSTI14 Normal Port5 Configuration - Priority
1.3.6.1.4.1.4756.20.501.20.1.1304ColumnnidMSTI14Port6PathCostRemoteAread-writecurrentNID Series card MSTI Port Configuration: MSTI14 Normal Port6 Configuration - Path Cost Valid values are in the range 0 to 200000000. Setting 0 means Auto path …
1.3.6.1.4.1.4756.20.501.20.1.1305ColumnnidMSTI14Port6PriorityRemoteAread-writecurrentNID Series card MSTI Port Configuration: MSTI14 Normal Port6 Configuration - Priority
1.3.6.1.4.1.4756.20.501.20.1.1306ColumnnidMSTI14Port7PathCostRemoteAread-writecurrentNID Series card MSTI Port Configuration: MSTI14 Normal Port7 Configuration - Path Cost Valid values are in the range 0 to 200000000. Setting 0 means Auto path …
1.3.6.1.4.1.4756.20.501.20.1.1307ColumnnidMSTI14Port7PriorityRemoteAread-writecurrentNID Series card MSTI Port Configuration: MSTI14 Normal Port7 Configuration - Priority
1.3.6.1.4.1.4756.20.501.20.1.1308ColumnnidMSTI14Port8PathCostRemoteAread-writecurrentNID Series card MSTI Port Configuration: MSTI8 Normal Port8 Configuration - Path Cost Valid values are in the range 0 to 200000000. Setting 0 means Auto path c…
1.3.6.1.4.1.4756.20.501.20.1.1309ColumnnidMSTI14Port8PriorityRemoteAread-writecurrentNID Series card MSTI Port Configuration: MSTI14 Normal Port8 Configuration - Priority
1.3.6.1.4.1.4756.20.501.20.1.1310ColumnnidMSTI15AggregatedPathCostRemoteAread-writecurrentNID Series card MSTI Port Configuration: MSTI15 Aggregated Ports Configuration - Path Cost Valid values are in the range 0 to 200000000. Setting 0 means Auto p…
1.3.6.1.4.1.4756.20.501.20.1.1311ColumnnidMSTI15AggregatedPriorityRemoteAread-writecurrentNID Series card MSTI Port Configuration: MSTI15 Aggregated Ports Configuration - Priority
1.3.6.1.4.1.4756.20.501.20.1.1312ColumnnidMSTI15Port1PathCostRemoteAread-writecurrentNID Series card MSTI Port Configuration: MSTI15 Normal Port1 Configuration - Path Cost Valid values are in the range 0 to 200000000. Setting 0 means Auto path …
1.3.6.1.4.1.4756.20.501.20.1.1313ColumnnidMSTI15Port1PriorityRemoteAread-writecurrentNID Series card MSTI Port Configuration: MSTI15 Normal Port1 Configuration - Priority
1.3.6.1.4.1.4756.20.501.20.1.1314ColumnnidMSTI15Port2PathCostRemoteAread-writecurrentNID Series card MSTI Port Configuration: MSTI15 Normal Port2 Configuration - Path Cost Valid values are in the range 0 to 200000000. Setting 0 means Auto path …
1.3.6.1.4.1.4756.20.501.20.1.1315ColumnnidMSTI15Port2PriorityRemoteAread-writecurrentNID Series card MSTI Port Configuration: MSTI8 Normal Port2 Configuration - Priority
1.3.6.1.4.1.4756.20.501.20.1.1316ColumnnidMSTI15Port3PathCostRemoteAread-writecurrentNID Series card MSTI Port Configuration: MSTI8 Normal Port3 Configuration - Path Cost Valid values are in the range 0 to 200000000. Setting 0 means Auto path c…
1.3.6.1.4.1.4756.20.501.20.1.1317ColumnnidMSTI15Port3PriorityRemoteAread-writecurrentNID Series card MSTI Port Configuration: MSTI15 Normal Port3 Configuration - Priority
1.3.6.1.4.1.4756.20.501.20.1.1318ColumnnidMSTI15Port4PathCostRemoteAread-writecurrentNID Series card MSTI Port Configuration: MSTI15 Normal Port4 Configuration - Path Cost Valid values are in the range 0 to 200000000. Setting 0 means Auto path …
1.3.6.1.4.1.4756.20.501.20.1.1319ColumnnidMSTI15Port4PriorityRemoteAread-writecurrentNID Series card MSTI Port Configuration: MSTI15 Normal Port4 Configuration - Priority
1.3.6.1.4.1.4756.20.501.20.1.1320ColumnnidMSTI15Port5PathCostRemoteAread-writecurrentNID Series card MSTI Port Configuration: MSTI15 Normal Port5 Configuration - Path Cost Valid values are in the range 0 to 200000000. Setting 0 means Auto path …
1.3.6.1.4.1.4756.20.501.20.1.1321ColumnnidMSTI15Port5PriorityRemoteAread-writecurrentNID Series card MSTI Port Configuration: MSTI15 Normal Port5 Configuration - Priority
1.3.6.1.4.1.4756.20.501.20.1.1322ColumnnidMSTI15Port6PathCostRemoteAread-writecurrentNID Series card MSTI Port Configuration: MSTI15 Normal Port6 Configuration - Path Cost Valid values are in the range 0 to 200000000. Setting 0 means Auto path …
1.3.6.1.4.1.4756.20.501.20.1.1323ColumnnidMSTI15Port6PriorityRemoteAread-writecurrentNID Series card MSTI Port Configuration: MSTI15 Normal Port6 Configuration - Priority
1.3.6.1.4.1.4756.20.501.20.1.1324ColumnnidMSTI15Port7PathCostRemoteAread-writecurrentNID Series card MSTI Port Configuration: MSTI15 Normal Port7 Configuration - Path Cost Valid values are in the range 0 to 200000000. Setting 0 means Auto path …
1.3.6.1.4.1.4756.20.501.20.1.1325ColumnnidMSTI15Port7PriorityRemoteAread-writecurrentNID Series card MSTI Port Configuration: MSTI15 Normal Port7 Configuration - Priority
1.3.6.1.4.1.4756.20.501.20.1.1326ColumnnidMSTI15Port8PathCostRemoteAread-writecurrentNID Series card MSTI Port Configuration: MSTI8 Normal Port8 Configuration - Path Cost Valid values are in the range 0 to 200000000. Setting 0 means Auto path c…
1.3.6.1.4.1.4756.20.501.20.1.1327ColumnnidMSTI15Port8PriorityRemoteAread-writecurrentNID Series card MSTI Port Configuration: MSTI15 Normal Port8 Configuration - Priority
1.3.6.1.4.1.4756.20.501.20.1.1328ColumnnidCISTBridgeIDRemoteAread-onlycurrentNID Series card STP Bridges status: CIST - Bridge ID
1.3.6.1.4.1.4756.20.501.20.1.1329ColumnnidCISTRootIDRemoteAread-onlycurrentNID Series card STP Bridges status: CIST - Root ID
1.3.6.1.4.1.4756.20.501.20.1.1330ColumnnidCISTRootPortRemoteAread-onlycurrentNID Series card STP Bridges status: CIST - Root Port
1.3.6.1.4.1.4756.20.501.20.1.1331ColumnnidCISTRootCostRemoteAread-onlycurrentNID Series card STP Bridges status: CIST - Root Cost
1.3.6.1.4.1.4756.20.501.20.1.1332ColumnnidCISTTopologyFlagRemoteAread-onlycurrentNID Series card STP Bridges status: CIST - Topology Flag
1.3.6.1.4.1.4756.20.501.20.1.1333ColumnnidCISTTopologyChangeLastRemoteAread-onlycurrentNID Series card STP Bridges status: CIST - Topology Change Last
1.3.6.1.4.1.4756.20.501.20.1.1334ColumnnidMSTI1BridgeIDRemoteAread-onlycurrentNID Series card STP Bridges status: MSTI1 - Bridge ID
1.3.6.1.4.1.4756.20.501.20.1.1335ColumnnidMSTI1RootIDRemoteAread-onlycurrentNID Series card STP Bridges status: MSTI1 - Root ID
1.3.6.1.4.1.4756.20.501.20.1.1336ColumnnidMSTI1RootPortRemoteAread-onlycurrentNID Series card STP Bridges status: MSTI1 - Root ID
1.3.6.1.4.1.4756.20.501.20.1.1337ColumnnidMSTI1RootCostRemoteAread-onlycurrentNID Series card STP Bridges status: MSTI1 - Root Cost
1.3.6.1.4.1.4756.20.501.20.1.1338ColumnnidMSTI1TopologyFlagRemoteAread-onlycurrentNID Series card STP Bridges status: MSTI1 - Topology Flag
1.3.6.1.4.1.4756.20.501.20.1.1339ColumnnidMSTI1TopologyChangeLastRemoteAread-onlycurrentNID Series card STP Bridges status: MSTI1 - Topology Change Last
1.3.6.1.4.1.4756.20.501.20.1.1340ColumnnidMSTI2BridgeIDRemoteAread-onlycurrentNID Series card STP Bridges status: MSTI2 - Bridge ID
1.3.6.1.4.1.4756.20.501.20.1.1341ColumnnidMSTI2RootIDRemoteAread-onlycurrentNID Series card STP Bridges status: MSTI2 - Root ID
1.3.6.1.4.1.4756.20.501.20.1.1342ColumnnidMSTI2RootPortRemoteAread-onlycurrentNID Series card STP Bridges status: MSTI2 - Root ID
1.3.6.1.4.1.4756.20.501.20.1.1343ColumnnidMSTI2RootCostRemoteAread-onlycurrentNID Series card STP Bridges status: MSTI2 - Root Cost
1.3.6.1.4.1.4756.20.501.20.1.1344ColumnnidMSTI2TopologyFlagRemoteAread-onlycurrentNID Series card STP Bridges status: MSTI2 - Topology Flag
1.3.6.1.4.1.4756.20.501.20.1.1345ColumnnidMSTI2TopologyChangeLastRemoteAread-onlycurrentNID Series card STP Bridges status: MSTI2 - Topology Change Last
1.3.6.1.4.1.4756.20.501.20.1.1346ColumnnidMSTI3BridgeIDRemoteAread-onlycurrentNID Series card STP Bridges status: MSTI3 - Bridge ID
1.3.6.1.4.1.4756.20.501.20.1.1347ColumnnidMSTI3RootIDRemoteAread-onlycurrentNID Series card STP Bridges status: MSTI3 - Root ID
1.3.6.1.4.1.4756.20.501.20.1.1348ColumnnidMSTI3RootPortRemoteAread-onlycurrentNID Series card STP Bridges status: MSTI3 - Root ID
1.3.6.1.4.1.4756.20.501.20.1.1349ColumnnidMSTI3RootCostRemoteAread-onlycurrentNID Series card STP Bridges status: MSTI3 - Root Cost
1.3.6.1.4.1.4756.20.501.20.1.1350ColumnnidMSTI3TopologyFlagRemoteAread-onlycurrentNID Series card STP Bridges status: MSTI3 - Topology Flag
1.3.6.1.4.1.4756.20.501.20.1.1351ColumnnidMSTI3TopologyChangeLastRemoteAread-onlycurrentNID Series card STP Bridges status: MSTI3 - Topology Change Last
1.3.6.1.4.1.4756.20.501.20.1.1352ColumnnidMSTI4BridgeIDRemoteAread-onlycurrentNID Series card STP Bridges status: MSTI4 - Bridge ID
1.3.6.1.4.1.4756.20.501.20.1.1353ColumnnidMSTI4RootIDRemoteAread-onlycurrentNID Series card STP Bridges status: MSTI4 - Root ID
1.3.6.1.4.1.4756.20.501.20.1.1354ColumnnidMSTI4RootPortRemoteAread-onlycurrentNID Series card STP Bridges status: MSTI4 - Root ID
1.3.6.1.4.1.4756.20.501.20.1.1355ColumnnidMSTI4RootCostRemoteAread-onlycurrentNID Series card STP Bridges status: MSTI4 - Root Cost
1.3.6.1.4.1.4756.20.501.20.1.1356ColumnnidMSTI4TopologyFlagRemoteAread-onlycurrentNID Series card STP Bridges status: MSTI4 - Topology Flag
1.3.6.1.4.1.4756.20.501.20.1.1357ColumnnidMSTI4TopologyChangeLastRemoteAread-onlycurrentNID Series card STP Bridges status: MSTI4 - Topology Change Last
1.3.6.1.4.1.4756.20.501.20.1.1358ColumnnidMSTI5BridgeIDRemoteAread-onlycurrentNID Series card STP Bridges status: MSTI5 - Bridge ID
1.3.6.1.4.1.4756.20.501.20.1.1359ColumnnidMSTI5RootIDRemoteAread-onlycurrentNID Series card STP Bridges status: MSTI5 - Root ID
1.3.6.1.4.1.4756.20.501.20.1.1360ColumnnidMSTI5RootPortRemoteAread-onlycurrentNID Series card STP Bridges status: MSTI5 - Root ID
1.3.6.1.4.1.4756.20.501.20.1.1361ColumnnidMSTI5RootCostRemoteAread-onlycurrentNID Series card STP Bridges status: MSTI5 - Root Cost
1.3.6.1.4.1.4756.20.501.20.1.1362ColumnnidMSTI5TopologyFlagRemoteAread-onlycurrentNID Series card STP Bridges status: MSTI5 - Topology Flag
1.3.6.1.4.1.4756.20.501.20.1.1363ColumnnidMSTI5TopologyChangeLastRemoteAread-onlycurrentNID Series card STP Bridges status: MSTI5 - Topology Change Last
1.3.6.1.4.1.4756.20.501.20.1.1364ColumnnidMSTI6BridgeIDRemoteAread-onlycurrentNID Series card STP Bridges status: MSTI6 - Bridge ID
1.3.6.1.4.1.4756.20.501.20.1.1365ColumnnidMSTI6RootIDRemoteAread-onlycurrentNID Series card STP Bridges status: MSTI6 - Root ID
1.3.6.1.4.1.4756.20.501.20.1.1366ColumnnidMSTI6RootPortRemoteAread-onlycurrentNID Series card STP Bridges status: MSTI6 - Root ID
1.3.6.1.4.1.4756.20.501.20.1.1367ColumnnidMSTI6RootCostRemoteAread-onlycurrentNID Series card STP Bridges status: MSTI6 - Root Cost
1.3.6.1.4.1.4756.20.501.20.1.1368ColumnnidMSTI6TopologyFlagRemoteAread-onlycurrentNID Series card STP Bridges status: MSTI6 - Topology Flag
1.3.6.1.4.1.4756.20.501.20.1.1369ColumnnidMSTI6TopologyChangeLastRemoteAread-onlycurrentNID Series card STP Bridges status: MSTI6 - Topology Change Last
1.3.6.1.4.1.4756.20.501.20.1.1370ColumnnidMSTI7BridgeIDRemoteAread-onlycurrentNID Series card STP Bridges status: MSTI7 - Bridge ID
1.3.6.1.4.1.4756.20.501.20.1.1371ColumnnidMSTI7RootIDRemoteAread-onlycurrentNID Series card STP Bridges status: MSTI7 - Root ID
1.3.6.1.4.1.4756.20.501.20.1.1372ColumnnidMSTI7RootPortRemoteAread-onlycurrentNID Series card STP Bridges status: MSTI7 - Root ID
1.3.6.1.4.1.4756.20.501.20.1.1373ColumnnidMSTI7RootCostRemoteAread-onlycurrentNID Series card STP Bridges status: MSTI7 - Root Cost
1.3.6.1.4.1.4756.20.501.20.1.1374ColumnnidMSTI7TopologyFlagRemoteAread-onlycurrentNID Series card STP Bridges status: MSTI7 - Topology Flag
1.3.6.1.4.1.4756.20.501.20.1.1375ColumnnidMSTI7TopologyChangeLastRemoteAread-onlycurrentNID Series card STP Bridges status: MSTI7 - Topology Change Last
1.3.6.1.4.1.4756.20.501.20.1.1376ColumnnidMSTI8BridgeIDRemoteAread-onlycurrentNID Series card STP Bridges status: MSTI8 - Bridge ID
1.3.6.1.4.1.4756.20.501.20.1.1377ColumnnidMSTI8RootIDRemoteAread-onlycurrentNID Series card STP Bridges status: MSTI8 - Root ID
1.3.6.1.4.1.4756.20.501.20.1.1378ColumnnidMSTI8RootPortRemoteAread-onlycurrentNID Series card STP Bridges status: MSTI8 - Root ID
1.3.6.1.4.1.4756.20.501.20.1.1379ColumnnidMSTI8RootCostRemoteAread-onlycurrentNID Series card STP Bridges status: MSTI8 - Root Cost
1.3.6.1.4.1.4756.20.501.20.1.1380ColumnnidMSTI8TopologyFlagRemoteAread-onlycurrentNID Series card STP Bridges status: MSTI8 - Topology Flag
1.3.6.1.4.1.4756.20.501.20.1.1381ColumnnidMSTI8TopologyChangeLastRemoteAread-onlycurrentNID Series card STP Bridges status: MSTI8 - Topology Change Last
1.3.6.1.4.1.4756.20.501.20.1.1382ColumnnidMSTI9BridgeIDRemoteAread-onlycurrentNID Series card STP Bridges status: MSTI9 - Bridge ID
1.3.6.1.4.1.4756.20.501.20.1.1383ColumnnidMSTI9RootIDRemoteAread-onlycurrentNID Series card STP Bridges status: MSTI9 - Root ID
1.3.6.1.4.1.4756.20.501.20.1.1384ColumnnidMSTI9RootPortRemoteAread-onlycurrentNID Series card STP Bridges status: MSTI9 - Root ID
1.3.6.1.4.1.4756.20.501.20.1.1385ColumnnidMSTI9RootCostRemoteAread-onlycurrentNID Series card STP Bridges status: MSTI9 - Root Cost
1.3.6.1.4.1.4756.20.501.20.1.1386ColumnnidMSTI9TopologyFlagRemoteAread-onlycurrentNID Series card STP Bridges status: MSTI9 - Topology Flag
1.3.6.1.4.1.4756.20.501.20.1.1387ColumnnidMSTI9TopologyChangeLastRemoteAread-onlycurrentNID Series card STP Bridges status: MSTI9 - Topology Change Last
1.3.6.1.4.1.4756.20.501.20.1.1388ColumnnidMSTI10BridgeIDRemoteAread-onlycurrentNID Series card STP Bridges status: MSTI10 - Bridge ID
1.3.6.1.4.1.4756.20.501.20.1.1389ColumnnidMSTI10RootIDRemoteAread-onlycurrentNID Series card STP Bridges status: MSTI10 - Root ID
1.3.6.1.4.1.4756.20.501.20.1.1390ColumnnidMSTI10RootPortRemoteAread-onlycurrentNID Series card STP Bridges status: MSTI10 - Root ID
1.3.6.1.4.1.4756.20.501.20.1.1391ColumnnidMSTI10RootCostRemoteAread-onlycurrentNID Series card STP Bridges status: MSTI10 - Root Cost
1.3.6.1.4.1.4756.20.501.20.1.1392ColumnnidMSTI10TopologyFlagRemoteAread-onlycurrentNID Series card STP Bridges status: MSTI10 - Topology Flag
1.3.6.1.4.1.4756.20.501.20.1.1393ColumnnidMSTI10TopologyChangeLastRemoteAread-onlycurrentNID Series card STP Bridges status: MSTI10 - Topology Change Last
1.3.6.1.4.1.4756.20.501.20.1.1394ColumnnidMSTI11BridgeIDRemoteAread-onlycurrentNID Series card STP Bridges status: MSTI11 - Bridge ID
1.3.6.1.4.1.4756.20.501.20.1.1395ColumnnidMSTI11RootIDRemoteAread-onlycurrentNID Series card STP Bridges status: MSTI11 - Root ID
1.3.6.1.4.1.4756.20.501.20.1.1396ColumnnidMSTI11RootPortRemoteAread-onlycurrentNID Series card STP Bridges status: MSTI11 - Root ID
1.3.6.1.4.1.4756.20.501.20.1.1397ColumnnidMSTI11RootCostRemoteAread-onlycurrentNID Series card STP Bridges status: MSTI11 - Root Cost
1.3.6.1.4.1.4756.20.501.20.1.1398ColumnnidMSTI11TopologyFlagRemoteAread-onlycurrentNID Series card STP Bridges status: MSTI11 - Topology Flag
1.3.6.1.4.1.4756.20.501.20.1.1399ColumnnidMSTI11TopologyChangeLastRemoteAread-onlycurrentNID Series card STP Bridges status: MSTI11 - Topology Change Last
1.3.6.1.4.1.4756.20.501.20.1.1400ColumnnidMSTI12BridgeIDRemoteAread-onlycurrentNID Series card STP Bridges status: MSTI12 - Bridge ID
1.3.6.1.4.1.4756.20.501.20.1.1401ColumnnidMSTI12RootIDRemoteAread-onlycurrentNID Series card STP Bridges status: MSTI12 - Root ID
1.3.6.1.4.1.4756.20.501.20.1.1402ColumnnidMSTI12RootPortRemoteAread-onlycurrentNID Series card STP Bridges status: MSTI12 - Root ID
1.3.6.1.4.1.4756.20.501.20.1.1403ColumnnidMSTI12RootCostRemoteAread-onlycurrentNID Series card STP Bridges status: MSTI12 - Root Cost
1.3.6.1.4.1.4756.20.501.20.1.1404ColumnnidMSTI12TopologyFlagRemoteAread-onlycurrentNID Series card STP Bridges status: MSTI12 - Topology Flag
1.3.6.1.4.1.4756.20.501.20.1.1405ColumnnidMSTI12TopologyChangeLastRemoteAread-onlycurrentNID Series card STP Bridges status: MSTI12 - Topology Change Last
1.3.6.1.4.1.4756.20.501.20.1.1406ColumnnidMSTI13BridgeIDRemoteAread-onlycurrentNID Series card STP Bridges status: MSTI13 - Bridge ID
1.3.6.1.4.1.4756.20.501.20.1.1407ColumnnidMSTI13RootIDRemoteAread-onlycurrentNID Series card STP Bridges status: MSTI13 - Root ID
1.3.6.1.4.1.4756.20.501.20.1.1408ColumnnidMSTI13RootPortRemoteAread-onlycurrentNID Series card STP Bridges status: MSTI13 - Root ID
1.3.6.1.4.1.4756.20.501.20.1.1409ColumnnidMSTI13RootCostRemoteAread-onlycurrentNID Series card STP Bridges status: MSTI13 - Root Cost
1.3.6.1.4.1.4756.20.501.20.1.1410ColumnnidMSTI13TopologyFlagRemoteAread-onlycurrentNID Series card STP Bridges status: MSTI13 - Topology Flag
1.3.6.1.4.1.4756.20.501.20.1.1411ColumnnidMSTI13TopologyChangeLastRemoteAread-onlycurrentNID Series card STP Bridges status: MSTI13 - Topology Change Last
1.3.6.1.4.1.4756.20.501.20.1.1412ColumnnidMSTI14BridgeIDRemoteAread-onlycurrentNID Series card STP Bridges status: MSTI14 - Bridge ID
1.3.6.1.4.1.4756.20.501.20.1.1413ColumnnidMSTI14RootIDRemoteAread-onlycurrentNID Series card STP Bridges status: MSTI14 - Root ID
1.3.6.1.4.1.4756.20.501.20.1.1414ColumnnidMSTI14RootPortRemoteAread-onlycurrentNID Series card STP Bridges status: MSTI14 - Root ID
1.3.6.1.4.1.4756.20.501.20.1.1415ColumnnidMSTI14RootCostRemoteAread-onlycurrentNID Series card STP Bridges status: MSTI14 - Root Cost
1.3.6.1.4.1.4756.20.501.20.1.1416ColumnnidMSTI14TopologyFlagRemoteAread-onlycurrentNID Series card STP Bridges status: MSTI14 - Topology Flag
1.3.6.1.4.1.4756.20.501.20.1.1417ColumnnidMSTI14TopologyChangeLastRemoteAread-onlycurrentNID Series card STP Bridges status: MSTI14 - Topology Change Last
1.3.6.1.4.1.4756.20.501.20.1.1418ColumnnidMSTI15BridgeIDRemoteAread-onlycurrentNID Series card STP Bridges status: MSTI15 - Bridge ID
1.3.6.1.4.1.4756.20.501.20.1.1419ColumnnidMSTI15RootIDRemoteAread-onlycurrentNID Series card STP Bridges status: MSTI15 - Root ID
1.3.6.1.4.1.4756.20.501.20.1.1420ColumnnidMSTI15RootPortRemoteAread-onlycurrentNID Series card STP Bridges status: MSTI15 - Root ID
1.3.6.1.4.1.4756.20.501.20.1.1421ColumnnidMSTI15RootCostRemoteAread-onlycurrentNID Series card STP Bridges status: MSTI15 - Root Cost
1.3.6.1.4.1.4756.20.501.20.1.1422ColumnnidMSTI15TopologyFlagRemoteAread-onlycurrentNID Series card STP Bridges status: MSTI15 - Topology Flag
1.3.6.1.4.1.4756.20.501.20.1.1423ColumnnidMSTI15TopologyChangeLastRemoteAread-onlycurrentNID Series card STP Bridges status: MSTI15 - Topology Change Last
1.3.6.1.4.1.4756.20.501.20.1.1424ColumnnidSTPPortStatusInst1PortRemoteAread-onlycurrentNID Series card STP Port status: Instance1 - Port
1.3.6.1.4.1.4756.20.501.20.1.1425ColumnnidSTPPortStatusInst1CISTRoleRemoteAread-onlycurrentNID Series card STP Port status: Instance1 - CIST Role
1.3.6.1.4.1.4756.20.501.20.1.1426ColumnnidSTPPortStatusInst1CISTStateRemoteAread-onlycurrentNID Series card STP Port status: Instance1 - CIST State
1.3.6.1.4.1.4756.20.501.20.1.1427ColumnnidSTPPortStatusInst1UptimeRemoteAread-onlycurrentNID Series card STP Port status: Instance1 -Uptime
1.3.6.1.4.1.4756.20.501.20.1.1428ColumnnidSTPPortStatusInst2PortRemoteAread-onlycurrentNID Series card STP Port status: Instance2 - Port
1.3.6.1.4.1.4756.20.501.20.1.1429ColumnnidSTPPortStatusInst2CISTRoleRemoteAread-onlycurrentNID Series card STP Port status: Instance2 - CIST Role
1.3.6.1.4.1.4756.20.501.20.1.1430ColumnnidSTPPortStatusInst2CISTStateRemoteAread-onlycurrentNID Series card STP Port status: Instance2 - CIST State
1.3.6.1.4.1.4756.20.501.20.1.1431ColumnnidSTPPortStatusInst2UptimeRemoteAread-onlycurrentNID Series card STP Port status: Instance2 -Uptime
1.3.6.1.4.1.4756.20.501.20.1.1432ColumnnidSTPPortStatusInst3PortRemoteAread-onlycurrentNID Series card STP Port status: Instance3 - Port
1.3.6.1.4.1.4756.20.501.20.1.1433ColumnnidSTPPortStatusInst3CISTRoleRemoteAread-onlycurrentNID Series card STP Port status: Instance3 - CIST Role
1.3.6.1.4.1.4756.20.501.20.1.1434ColumnnidSTPPortStatusInst3CISTStateRemoteAread-onlycurrentNID Series card STP Port status: Instance3 - CIST State
1.3.6.1.4.1.4756.20.501.20.1.1435ColumnnidSTPPortStatusInst3UptimeRemoteAread-onlycurrentNID Series card STP Port status: Instance3 -Uptime
1.3.6.1.4.1.4756.20.501.20.1.1436ColumnnidSTPPortStatusInst4PortRemoteAread-onlycurrentNID Series card STP Port status: Instance4 - Port
1.3.6.1.4.1.4756.20.501.20.1.1437ColumnnidSTPPortStatusInst4CISTRoleRemoteAread-onlycurrentNID Series card STP Port status: Instance4 - CIST Role
1.3.6.1.4.1.4756.20.501.20.1.1438ColumnnidSTPPortStatusInst4CISTStateRemoteAread-onlycurrentNID Series card STP Port status: Instance4 - CIST State
1.3.6.1.4.1.4756.20.501.20.1.1439ColumnnidSTPPortStatusInst4UptimeRemoteAread-onlycurrentNID Series card STP Port status: Instance4 -Uptime
1.3.6.1.4.1.4756.20.501.20.1.1440ColumnnidSTPPortStatusInst5PortRemoteAread-onlycurrentNID Series card STP Port status: Instance5 - Port
1.3.6.1.4.1.4756.20.501.20.1.1441ColumnnidSTPPortStatusInst5CISTRoleRemoteAread-onlycurrentNID Series card STP Port status: Instance5 - CIST Role
1.3.6.1.4.1.4756.20.501.20.1.1442ColumnnidSTPPortStatusInst5CISTStateRemoteAread-onlycurrentNID Series card STP Port status: Instance5 - CIST State
1.3.6.1.4.1.4756.20.501.20.1.1443ColumnnidSTPPortStatusInst5UptimeRemoteAread-onlycurrentNID Series card STP Port status: Instance5 -Uptime
1.3.6.1.4.1.4756.20.501.20.1.1444ColumnnidSTPPortStatusInst6PortRemoteAread-onlycurrentNID Series card STP Port status: Instance6- Port
1.3.6.1.4.1.4756.20.501.20.1.1445ColumnnidSTPPortStatusInst6CISTRoleRemoteAread-onlycurrentNID Series card STP Port status: Instance6- CIST Role
1.3.6.1.4.1.4756.20.501.20.1.1446ColumnnidSTPPortStatusInst6CISTStateRemoteAread-onlycurrentNID Series card STP Port status: Instance6- CIST State
1.3.6.1.4.1.4756.20.501.20.1.1447ColumnnidSTPPortStatusInst6UptimeRemoteAread-onlycurrentNID Series card STP Port status: Instance6-Uptime
1.3.6.1.4.1.4756.20.501.20.1.1448ColumnnidSTPPortStatusInst7PortRemoteAread-onlycurrentNID Series card STP Port status: Instance7- Port
1.3.6.1.4.1.4756.20.501.20.1.1449ColumnnidSTPPortStatusInst7CISTRoleRemoteAread-onlycurrentNID Series card STP Port status: Instance7- CIST Role
1.3.6.1.4.1.4756.20.501.20.1.1450ColumnnidSTPPortStatusInst7CISTStateRemoteAread-onlycurrentNID Series card STP Port status: Instance7- CIST State
1.3.6.1.4.1.4756.20.501.20.1.1451ColumnnidSTPPortStatusInst7UptimeRemoteAread-onlycurrentNID Series card STP Port status: Instance7-Uptime
1.3.6.1.4.1.4756.20.501.20.1.1452ColumnnidSTPPortStatusInst8PortRemoteAread-onlycurrentNID Series card STP Port status: Instance8- Port
1.3.6.1.4.1.4756.20.501.20.1.1453ColumnnidSTPPortStatusInst8CISTRoleRemoteAread-onlycurrentNID Series card STP Port status: Instance8- CIST Role
1.3.6.1.4.1.4756.20.501.20.1.1454ColumnnidSTPPortStatusInst8CISTStateRemoteAread-onlycurrentNID Series card STP Port status: Instance8- CIST State
1.3.6.1.4.1.4756.20.501.20.1.1455ColumnnidSTPPortStatusInst8UptimeRemoteAread-onlycurrentNID Series card STP Port status: Instance8-Uptime
1.3.6.1.4.1.4756.20.501.20.1.1456ColumnnidSTPStatisticsPort1TxMSTPRemoteAread-onlycurrentNID Series card STP Port Statistics: Port1 -Transmitted MSTP
1.3.6.1.4.1.4756.20.501.20.1.1457ColumnnidSTPStatisticsPort1TxRSTPRemoteAread-onlycurrentNID Series card STP Port Statistics: Port1 -Transmitted RSTP
1.3.6.1.4.1.4756.20.501.20.1.1458ColumnnidSTPStatisticsPort1TxSTPRemoteAread-onlycurrentNID Series card STP Port Statistics: Port1 -Transmitted RSTP
1.3.6.1.4.1.4756.20.501.20.1.1459ColumnnidSTPStatisticsPort1TxTCNRemoteAread-onlycurrentNID Series card STP Port Statistics: Port1 -Transmitted RSTP
1.3.6.1.4.1.4756.20.501.20.1.1460ColumnnidSTPStatisticsPort1RxMSTPRemoteAread-onlycurrentNID Series card STP Port Statistics: Port1 -Received MSTP
1.3.6.1.4.1.4756.20.501.20.1.1461ColumnnidSTPStatisticsPort1RxRSTPRemoteAread-onlycurrentNID Series card STP Port Statistics: Port1 -Received RSTP
1.3.6.1.4.1.4756.20.501.20.1.1462ColumnnidSTPStatisticsPort1RxSTPRemoteAread-onlycurrentNID Series card STP Port Statistics: Port1 -Received RSTP
1.3.6.1.4.1.4756.20.501.20.1.1463ColumnnidSTPStatisticsPort1RxTCNRemoteAread-onlycurrentNID Series card STP Port Statistics: Port1 -Received RSTP
1.3.6.1.4.1.4756.20.501.20.1.1464ColumnnidSTPStatisticsPort1DiscardUnknowRemoteAread-onlycurrentNID Series card STP Port Statistics: Port1 -Discarded Unknown
1.3.6.1.4.1.4756.20.501.20.1.1465ColumnnidSTPStatisticsPort1DiscardIllegalRemoteAread-onlycurrentNID Series card STP Port Statistics: Port1 -Discarded Illegal
1.3.6.1.4.1.4756.20.501.20.1.1466ColumnnidSTPStatisticsPort2TxMSTPRemoteAread-onlycurrentNID Series card STP Port Statistics: Port2 -Transmitted MSTP
1.3.6.1.4.1.4756.20.501.20.1.1467ColumnnidSTPStatisticsPort2TxRSTPRemoteAread-onlycurrentNID Series card STP Port Statistics: Port2 -Transmitted RSTP
1.3.6.1.4.1.4756.20.501.20.1.1468ColumnnidSTPStatisticsPort2TxSTPRemoteAread-onlycurrentNID Series card STP Port Statistics: Port2 -Transmitted RSTP
1.3.6.1.4.1.4756.20.501.20.1.1469ColumnnidSTPStatisticsPort2TxTCNRemoteAread-onlycurrentNID Series card STP Port Statistics: Port2 -Transmitted RSTP
1.3.6.1.4.1.4756.20.501.20.1.1470ColumnnidSTPStatisticsPort2RxMSTPRemoteAread-onlycurrentNID Series card STP Port Statistics: Port2 -Received MSTP
1.3.6.1.4.1.4756.20.501.20.1.1471ColumnnidSTPStatisticsPort2RxRSTPRemoteAread-onlycurrentNID Series card STP Port Statistics: Port1 -Received RSTP
1.3.6.1.4.1.4756.20.501.20.1.1472ColumnnidSTPStatisticsPort2RxSTPRemoteAread-onlycurrentNID Series card STP Port Statistics: Port2 -Received RSTP
1.3.6.1.4.1.4756.20.501.20.1.1473ColumnnidSTPStatisticsPort2RxTCNRemoteAread-onlycurrentNID Series card STP Port Statistics: Port2 -Received RSTP
1.3.6.1.4.1.4756.20.501.20.1.1474ColumnnidSTPStatisticsPort2DiscardUnknowRemoteAread-onlycurrentNID Series card STP Port Statistics: Port2 -Discarded Unknown
1.3.6.1.4.1.4756.20.501.20.1.1475ColumnnidSTPStatisticsPort2DiscardIllegalRemoteAread-onlycurrentNID Series card STP Port Statistics: Port2 -Discarded Illegal
1.3.6.1.4.1.4756.20.501.20.1.1476ColumnnidSTPStatisticsPort3TxMSTPRemoteAread-onlycurrentNID Series card STP Port Statistics: Port3 -Transmitted MSTP
1.3.6.1.4.1.4756.20.501.20.1.1477ColumnnidSTPStatisticsPort3TxRSTPRemoteAread-onlycurrentNID Series card STP Port Statistics: Port3 -Transmitted RSTP
1.3.6.1.4.1.4756.20.501.20.1.1478ColumnnidSTPStatisticsPort3TxSTPRemoteAread-onlycurrentNID Series card STP Port Statistics: Port3 -Transmitted RSTP
1.3.6.1.4.1.4756.20.501.20.1.1479ColumnnidSTPStatisticsPort3TxTCNRemoteAread-onlycurrentNID Series card STP Port Statistics: Port3 -Transmitted RSTP
1.3.6.1.4.1.4756.20.501.20.1.1480ColumnnidSTPStatisticsPort3RxMSTPRemoteAread-onlycurrentNID Series card STP Port Statistics: Port3 -Received MSTP
1.3.6.1.4.1.4756.20.501.20.1.1481ColumnnidSTPStatisticsPort3RxRSTPRemoteAread-onlycurrentNID Series card STP Port Statistics: Port3 -Received RSTP
1.3.6.1.4.1.4756.20.501.20.1.1482ColumnnidSTPStatisticsPort3RxSTPRemoteAread-onlycurrentNID Series card STP Port Statistics: Port3 -Received RSTP
1.3.6.1.4.1.4756.20.501.20.1.1483ColumnnidSTPStatisticsPort3RxTCNRemoteAread-onlycurrentNID Series card STP Port Statistics: Port3 -Received RSTP
1.3.6.1.4.1.4756.20.501.20.1.1484ColumnnidSTPStatisticsPort3DiscardUnknowRemoteAread-onlycurrentNID Series card STP Port Statistics: Port3 -Discarded Unknown
1.3.6.1.4.1.4756.20.501.20.1.1485ColumnnidSTPStatisticsPort3DiscardIllegalRemoteAread-onlycurrentNID Series card STP Port Statistics: Port3 -Discarded Illegal
1.3.6.1.4.1.4756.20.501.20.1.1486ColumnnidSTPStatisticsPort4TxMSTPRemoteAread-onlycurrentNID Series card STP Port Statistics: Port4 -Transmitted MSTP
1.3.6.1.4.1.4756.20.501.20.1.1487ColumnnidSTPStatisticsPort4TxRSTPRemoteAread-onlycurrentNID Series card STP Port Statistics: Port4 -Transmitted RSTP
1.3.6.1.4.1.4756.20.501.20.1.1488ColumnnidSTPStatisticsPort4TxSTPRemoteAread-onlycurrentNID Series card STP Port Statistics: Port4 -Transmitted RSTP
1.3.6.1.4.1.4756.20.501.20.1.1489ColumnnidSTPStatisticsPort4TxTCNRemoteAread-onlycurrentNID Series card STP Port Statistics: Port4 -Transmitted RSTP
1.3.6.1.4.1.4756.20.501.20.1.1490ColumnnidSTPStatisticsPort4RxMSTPRemoteAread-onlycurrentNID Series card STP Port Statistics: Port4 -Received MSTP
1.3.6.1.4.1.4756.20.501.20.1.1491ColumnnidSTPStatisticsPort4RxRSTPRemoteAread-onlycurrentNID Series card STP Port Statistics: Port4 -Received RSTP
1.3.6.1.4.1.4756.20.501.20.1.1492ColumnnidSTPStatisticsPort4RxSTPRemoteAread-onlycurrentNID Series card STP Port Statistics: Port4 -Received RSTP
1.3.6.1.4.1.4756.20.501.20.1.1493ColumnnidSTPStatisticsPort4RxTCNRemoteAread-onlycurrentNID Series card STP Port Statistics: Port4 -Received RSTP
1.3.6.1.4.1.4756.20.501.20.1.1494ColumnnidSTPStatisticsPort4DiscardUnknowRemoteAread-onlycurrentNID Series card STP Port Statistics: Port4 -Discarded Unknown
1.3.6.1.4.1.4756.20.501.20.1.1495ColumnnidSTPStatisticsPort4DiscardIllegalRemoteAread-onlycurrentNID Series card STP Port Statistics: Port4 -Discarded Illegal
1.3.6.1.4.1.4756.20.501.20.1.1496ColumnnidSTPStatisticsPort5TxMSTPRemoteAread-onlycurrentNID Series card STP Port Statistics: Port5 -Transmitted MSTP
1.3.6.1.4.1.4756.20.501.20.1.1497ColumnnidSTPStatisticsPort5TxRSTPRemoteAread-onlycurrentNID Series card STP Port Statistics: Port5 -Transmitted RSTP
1.3.6.1.4.1.4756.20.501.20.1.1498ColumnnidSTPStatisticsPort5TxSTPRemoteAread-onlycurrentNID Series card STP Port Statistics: Port5 -Transmitted RSTP
1.3.6.1.4.1.4756.20.501.20.1.1499ColumnnidSTPStatisticsPort5TxTCNRemoteAread-onlycurrentNID Series card STP Port Statistics: Port5 -Transmitted RSTP
1.3.6.1.4.1.4756.20.501.20.1.1500ColumnnidSTPStatisticsPort5RxMSTPRemoteAread-onlycurrentNID Series card STP Port Statistics: Port5 -Received MSTP
1.3.6.1.4.1.4756.20.501.20.1.1501ColumnnidSTPStatisticsPort5RxRSTPRemoteAread-onlycurrentNID Series card STP Port Statistics: Port5 -Received RSTP
1.3.6.1.4.1.4756.20.501.20.1.1502ColumnnidSTPStatisticsPort5RxSTPRemoteAread-onlycurrentNID Series card STP Port Statistics: Port5 -Received RSTP
1.3.6.1.4.1.4756.20.501.20.1.1503ColumnnidSTPStatisticsPort5RxTCNRemoteAread-onlycurrentNID Series card STP Port Statistics: Port5 -Received RSTP
1.3.6.1.4.1.4756.20.501.20.1.1504ColumnnidSTPStatisticsPort5DiscardUnknowRemoteAread-onlycurrentNID Series card STP Port Statistics: Port5 -Discarded Unknown
1.3.6.1.4.1.4756.20.501.20.1.1505ColumnnidSTPStatisticsPort5DiscardIllegalRemoteAread-onlycurrentNID Series card STP Port Statistics: Port5 -Discarded Illegal
1.3.6.1.4.1.4756.20.501.20.1.1506ColumnnidSTPStatisticsPort6TxMSTPRemoteAread-onlycurrentNID Series card STP Port Statistics: Port6 -Transmitted MSTP
1.3.6.1.4.1.4756.20.501.20.1.1507ColumnnidSTPStatisticsPort6TxRSTPRemoteAread-onlycurrentNID Series card STP Port Statistics: Port6 -Transmitted RSTP
1.3.6.1.4.1.4756.20.501.20.1.1508ColumnnidSTPStatisticsPort6TxSTPRemoteAread-onlycurrentNID Series card STP Port Statistics: Port6 -Transmitted RSTP
1.3.6.1.4.1.4756.20.501.20.1.1509ColumnnidSTPStatisticsPort6TxTCNRemoteAread-onlycurrentNID Series card STP Port Statistics: Port6 -Transmitted RSTP
1.3.6.1.4.1.4756.20.501.20.1.1510ColumnnidSTPStatisticsPort6RxMSTPRemoteAread-onlycurrentNID Series card STP Port Statistics: Port6 -Received MSTP
1.3.6.1.4.1.4756.20.501.20.1.1511ColumnnidSTPStatisticsPort6RxRSTPRemoteAread-onlycurrentNID Series card STP Port Statistics: Port6 -Received RSTP
1.3.6.1.4.1.4756.20.501.20.1.1512ColumnnidSTPStatisticsPort6RxSTPRemoteAread-onlycurrentNID Series card STP Port Statistics: Port6 -Received RSTP
1.3.6.1.4.1.4756.20.501.20.1.1513ColumnnidSTPStatisticsPort6RxTCNRemoteAread-onlycurrentNID Series card STP Port Statistics: Port6 -Received RSTP
1.3.6.1.4.1.4756.20.501.20.1.1514ColumnnidSTPStatisticsPort6DiscardUnknowRemoteAread-onlycurrentNID Series card STP Port Statistics: Port6 -Discarded Unknown
1.3.6.1.4.1.4756.20.501.20.1.1515ColumnnidSTPStatisticsPort6DiscardIllegalRemoteAread-onlycurrentNID Series card STP Port Statistics: Port6 -Discarded Illegal
1.3.6.1.4.1.4756.20.501.20.1.1516ColumnnidSTPStatisticsPort7TxMSTPRemoteAread-onlycurrentNID Series card STP Port Statistics: Port7 -Transmitted MSTP
1.3.6.1.4.1.4756.20.501.20.1.1517ColumnnidSTPStatisticsPort7TxRSTPRemoteAread-onlycurrentNID Series card STP Port Statistics: Port7 -Transmitted RSTP
1.3.6.1.4.1.4756.20.501.20.1.1518ColumnnidSTPStatisticsPort7TxSTPRemoteAread-onlycurrentNID Series card STP Port Statistics: Port7 -Transmitted RSTP
1.3.6.1.4.1.4756.20.501.20.1.1519ColumnnidSTPStatisticsPort7TxTCNRemoteAread-onlycurrentNID Series card STP Port Statistics: Port7 -Transmitted RSTP
1.3.6.1.4.1.4756.20.501.20.1.1520ColumnnidSTPStatisticsPort7RxMSTPRemoteAread-onlycurrentNID Series card STP Port Statistics: Port7 -Received MSTP
1.3.6.1.4.1.4756.20.501.20.1.1521ColumnnidSTPStatisticsPort7RxRSTPRemoteAread-onlycurrentNID Series card STP Port Statistics: Port7 -Received RSTP
1.3.6.1.4.1.4756.20.501.20.1.1522ColumnnidSTPStatisticsPort7RxSTPRemoteAread-onlycurrentNID Series card STP Port Statistics: Port7 -Received RSTP
1.3.6.1.4.1.4756.20.501.20.1.1523ColumnnidSTPStatisticsPort7RxTCNRemoteAread-onlycurrentNID Series card STP Port Statistics: Port7 -Received RSTP
1.3.6.1.4.1.4756.20.501.20.1.1524ColumnnidSTPStatisticsPort7DiscardUnknowRemoteAread-onlycurrentNID Series card STP Port Statistics: Port7 -Discarded Unknown
1.3.6.1.4.1.4756.20.501.20.1.1525ColumnnidSTPStatisticsPort7DiscardIllegalRemoteAread-onlycurrentNID Series card STP Port Statistics: Port7 -Discarded Illegal
1.3.6.1.4.1.4756.20.501.20.1.1526ColumnnidSTPStatisticsPort8TxMSTPRemoteAread-onlycurrentNID Series card STP Port Statistics: Port8 -Transmitted MSTP
1.3.6.1.4.1.4756.20.501.20.1.1527ColumnnidSTPStatisticsPort8TxRSTPRemoteAread-onlycurrentNID Series card STP Port Statistics: Port8 -Transmitted RSTP
1.3.6.1.4.1.4756.20.501.20.1.1528ColumnnidSTPStatisticsPort8TxSTPRemoteAread-onlycurrentNID Series card STP Port Statistics: Port8 -Transmitted RSTP
1.3.6.1.4.1.4756.20.501.20.1.1529ColumnnidSTPStatisticsPort8TxTCNRemoteAread-onlycurrentNID Series card STP Port Statistics: Port8 -Transmitted RSTP
1.3.6.1.4.1.4756.20.501.20.1.1530ColumnnidSTPStatisticsPort8RxMSTPRemoteAread-onlycurrentNID Series card STP Port Statistics: Port8 -Received MSTP
1.3.6.1.4.1.4756.20.501.20.1.1531ColumnnidSTPStatisticsPort8RxRSTPRemoteAread-onlycurrentNID Series card STP Port Statistics: Port8 -Received RSTP
1.3.6.1.4.1.4756.20.501.20.1.1532ColumnnidSTPStatisticsPort8RxSTPRemoteAread-onlycurrentNID Series card STP Port Statistics: Port8 -Received RSTP
1.3.6.1.4.1.4756.20.501.20.1.1533ColumnnidSTPStatisticsPort8RxTCNRemoteAread-onlycurrentNID Series card STP Port Statistics: Port8 -Received RSTP
1.3.6.1.4.1.4756.20.501.20.1.1534ColumnnidSTPStatisticsPort8DiscardUnknowRemoteAread-onlycurrentNID Series card STP Port Statistics: Port8 -Discarded Unknown
1.3.6.1.4.1.4756.20.501.20.1.1535ColumnnidSTPStatisticsPort8DiscardIllegalRemoteAread-onlycurrentNID Series card STP Port Statistics: Port8 -Discarded Illegal
1.3.6.1.4.1.4756.20.501.20.1.1536ColumnnidAllowedAccessVLANsRemoteAread-writecurrentNID Series card Global VLAN Configuration: Allowed Access VLANs By default, only VLAN 1 is enabled. More VLANs may be created by using a list syntax where the …
1.3.6.1.4.1.4756.20.501.20.1.1537ColumnnidVlanEthertypeRemoteAread-writecurrentNID Series card Global VLAN Configuration: Ethertype for Custom S-ports The format of 'Ethernet Type' is restricted to 0x600-0xFFFF
1.3.6.1.4.1.4756.20.501.20.1.1538ColumnnidPort1VlanModeRemoteAread-writecurrentNID Series card Port VLAN Configuration : Port1 - Mode 0: Access 1: Trunk 2: Hybrid
1.3.6.1.4.1.4756.20.501.20.1.1539ColumnnidPort1VlanIDRemoteAread-writecurrentNID Series card Port VLAN Configuration : Port1 - VLAN ID
1.3.6.1.4.1.4756.20.501.20.1.1540ColumnnidPort1VlanTypeRemoteAread-writecurrentNID Series card Port VLAN Configuration : Port1 - VLAN Type 0: Unaware 1: C-port 2: S-port 3: S-custom-port
1.3.6.1.4.1.4756.20.501.20.1.1541ColumnnidPort1VlanIngressFilteringRemoteAread-writecurrentNID Series card Port VLAN Configuration : Port1 - Ingress Filtering 0: Off 1: On
1.3.6.1.4.1.4756.20.501.20.1.1542ColumnnidPort1VlanIngressAcceptanceRemoteAread-writecurrentNID Series card Port VLAN Configuration : Port1 - Ingress Acceptance 0: Tagged and untagged 1: Tagged only 2: Untagged only
1.3.6.1.4.1.4756.20.501.20.1.1543ColumnnidPort1VlanEgressTaggingRemoteAread-writecurrentNID Series card Port VLAN Configuration : Port1 - Egress Tagging 0: Untag port vlan 1: Tag all 2: Untag all
1.3.6.1.4.1.4756.20.501.20.1.1544ColumnnidPort1AllowedVLANSRemoteAread-writecurrentNID Series card Global VLAN Configuration: Port1 - Allowed VLANs By default, only VLAN 1 is enabled. More VLANs may be created by using a list syntax where the…
1.3.6.1.4.1.4756.20.501.20.1.1545ColumnnidPort1ForbiddenVLANSRemoteAread-writecurrentNID Series card Global VLAN Configuration: Port1 - Forbidden VLANs By default, the field is left blank, which means that the port may become a member of all po…
1.3.6.1.4.1.4756.20.501.20.1.1546ColumnnidPort2VlanModeRemoteAread-writecurrentNID Series card Port VLAN Configuration : Port2 - Mode 0: Access 1: Trunk 2: Hybrid
1.3.6.1.4.1.4756.20.501.20.1.1547ColumnnidPort2VlanIDRemoteAread-writecurrentNID Series card Port VLAN Configuration : Port2 - VLAN ID
1.3.6.1.4.1.4756.20.501.20.1.1548ColumnnidPort2VlanTypeRemoteAread-writecurrentNID Series card Port VLAN Configuration : Port2 - VLAN Type 0: Unaware 1: C-port 2: S-port 3: S-custom-port
1.3.6.1.4.1.4756.20.501.20.1.1549ColumnnidPort2VlanIngressFilteringRemoteAread-writecurrentNID Series card Port VLAN Configuration : Port2 - Ingress Filtering 0: Off 1: On
1.3.6.1.4.1.4756.20.501.20.1.1550ColumnnidPort2VlanIngressAcceptanceRemoteAread-writecurrentNID Series card Port VLAN Configuration : Por2 - Ingress Acceptance 0: Tagged and untagged 1: Tagged only 2: Untagged only
1.3.6.1.4.1.4756.20.501.20.1.1551ColumnnidPort2VlanEgressTaggingRemoteAread-writecurrentNID Series card Port VLAN Configuration : Port2 - Egress Tagging 0: Untag port vlan 1: Tag all 2: Untag all
1.3.6.1.4.1.4756.20.501.20.1.1552ColumnnidPort2AllowedVLANSRemoteAread-writecurrentNID Series card Global VLAN Configuration: Port2 - Allowed VLANs By default, only VLAN 1 is enabled. More VLANs may be created by using a list syntax where the…
1.3.6.1.4.1.4756.20.501.20.1.1553ColumnnidPort2ForbiddenVLANSRemoteAread-writecurrentNID Series card Global VLAN Configuration: Port2 - Forbidden VLANs By default, the field is left blank, which means that the port may become a member of all po…
1.3.6.1.4.1.4756.20.501.20.1.1554ColumnnidPort3VlanModeRemoteAread-writecurrentNID Series card Port VLAN Configuration : Port3 - Mode 0: Access 1: Trunk 2: Hybrid
1.3.6.1.4.1.4756.20.501.20.1.1555ColumnnidPort3VlanIDRemoteAread-writecurrentNID Series card Port VLAN Configuration : Port3 - VLAN ID
1.3.6.1.4.1.4756.20.501.20.1.1556ColumnnidPort3VlanTypeRemoteAread-writecurrentNID Series card Port VLAN Configuration : Port3 - VLAN Type 0: Unaware 1: C-port 2: S-port 3: S-custom-port
1.3.6.1.4.1.4756.20.501.20.1.1557ColumnnidPort3VlanIngressFilteringRemoteAread-writecurrentNID Series card Port VLAN Configuration : Port3 - Ingress Filtering 0: Off 1: On
1.3.6.1.4.1.4756.20.501.20.1.1558ColumnnidPort3VlanIngressAcceptanceRemoteAread-writecurrentNID Series card Port VLAN Configuration : Port3 - Ingress Acceptance 0: Tagged and untagged 1: Tagged only 2: Untagged only
1.3.6.1.4.1.4756.20.501.20.1.1559ColumnnidPort3VlanEgressTaggingRemoteAread-writecurrentNID Series card Port VLAN Configuration : Port3 - Egress Tagging 0: Untag port vlan 1: Tag all 2: Untag all
1.3.6.1.4.1.4756.20.501.20.1.1560ColumnnidPort3AllowedVLANSRemoteAread-writecurrentNID Series card Global VLAN Configuration: Port3 - Allowed VLANs By default, only VLAN 1 is enabled. More VLANs may be created by using a list syntax where the…
1.3.6.1.4.1.4756.20.501.20.1.1561ColumnnidPort3ForbiddenVLANSRemoteAread-writecurrentNID Series card Global VLAN Configuration: Port3 - Forbidden VLANs By default, the field is left blank, which means that the port may become a member of all po…
1.3.6.1.4.1.4756.20.501.20.1.1562ColumnnidPort4VlanModeRemoteAread-writecurrentNID Series card Port VLAN Configuration : Port4 - Mode 0: Access 1: Trunk 2: Hybrid
1.3.6.1.4.1.4756.20.501.20.1.1563ColumnnidPort4VlanIDRemoteAread-writecurrentNID Series card Port VLAN Configuration : Port4 - VLAN ID
1.3.6.1.4.1.4756.20.501.20.1.1564ColumnnidPort4VlanTypeRemoteAread-writecurrentNID Series card Port VLAN Configuration : Port4 - VLAN Type 0: Unaware 1: C-port 2: S-port 3: S-custom-port
1.3.6.1.4.1.4756.20.501.20.1.1565ColumnnidPort4VlanIngressFilteringRemoteAread-writecurrentNID Series card Port VLAN Configuration : Port4 - Ingress Filtering 0: Off 1: On
1.3.6.1.4.1.4756.20.501.20.1.1566ColumnnidPort4VlanIngressAcceptanceRemoteAread-writecurrentNID Series card Port VLAN Configuration : Port4 - Ingress Acceptance 0: Tagged and untagged 1: Tagged only 2: Untagged only
1.3.6.1.4.1.4756.20.501.20.1.1567ColumnnidPort4VlanEgressTaggingRemoteAread-writecurrentNID Series card Port VLAN Configuration : Port4 - Egress Tagging 0: Untag port vlan 1: Tag all 2: Untag all
1.3.6.1.4.1.4756.20.501.20.1.1568ColumnnidPort4AllowedVLANSRemoteAread-writecurrentNID Series card Global VLAN Configuration: Port4 - Allowed VLANs By default, only VLAN 1 is enabled. More VLANs may be created by using a list syntax where the…
1.3.6.1.4.1.4756.20.501.20.1.1569ColumnnidPort4ForbiddenVLANSRemoteAread-writecurrentNID Series card Global VLAN Configuration: Port4 - Forbidden VLANs By default, the field is left blank, which means that the port may become a member of all po…
1.3.6.1.4.1.4756.20.501.20.1.1570ColumnnidPort5VlanModeRemoteAread-writecurrentNID Series card Port VLAN Configuration : Port5 - Mode 0: Access 1: Trunk 2: Hybrid
1.3.6.1.4.1.4756.20.501.20.1.1571ColumnnidPort5VlanIDRemoteAread-writecurrentNID Series card Port VLAN Configuration : Port5 - VLAN ID
1.3.6.1.4.1.4756.20.501.20.1.1572ColumnnidPort5VlanTypeRemoteAread-writecurrentNID Series card Port VLAN Configuration : Port5 - VLAN Type 0: Unaware 1: C-port 2: S-port 3: S-custom-port
1.3.6.1.4.1.4756.20.501.20.1.1573ColumnnidPort5VlanIngressFilteringRemoteAread-writecurrentNID Series card Port VLAN Configuration : Port5 - Ingress Filtering 0: Off 1: On
1.3.6.1.4.1.4756.20.501.20.1.1574ColumnnidPort5VlanIngressAcceptanceRemoteAread-writecurrentNID Series card Port VLAN Configuration : Port5 - Ingress Acceptance 0: Tagged and untagged 1: Tagged only 2: Untagged only
1.3.6.1.4.1.4756.20.501.20.1.1575ColumnnidPort5VlanEgressTaggingRemoteAread-writecurrentNID Series card Port VLAN Configuration : Port5 - Egress Tagging 0: Untag port vlan 1: Tag all 2: Untag all
1.3.6.1.4.1.4756.20.501.20.1.1576ColumnnidPort5AllowedVLANSRemoteAread-writecurrentNID Series card Global VLAN Configuration: Port5 - Allowed VLANs By default, only VLAN 1 is enabled. More VLANs may be created by using a list syntax where the…
1.3.6.1.4.1.4756.20.501.20.1.1577ColumnnidPort5ForbiddenVLANSRemoteAread-writecurrentNID Series card Global VLAN Configuration: Port5 - Forbidden VLANs By default, the field is left blank, which means that the port may become a member of all po…
1.3.6.1.4.1.4756.20.501.20.1.1578ColumnnidPort6VlanModeRemoteAread-writecurrentNID Series card Port VLAN Configuration : Port6 - Mode 0: Access 1: Trunk 2: Hybrid
1.3.6.1.4.1.4756.20.501.20.1.1579ColumnnidPort6VlanIDRemoteAread-writecurrentNID Series card Port VLAN Configuration : Port6 - VLAN ID
1.3.6.1.4.1.4756.20.501.20.1.1580ColumnnidPort6VlanTypeRemoteAread-writecurrentNID Series card Port VLAN Configuration : Port6 - VLAN Type 0: Unaware 1: C-port 2: S-port 3: S-custom-port
1.3.6.1.4.1.4756.20.501.20.1.1581ColumnnidPort6VlanIngressFilteringRemoteAread-writecurrentNID Series card Port VLAN Configuration : Port6 - Ingress Filtering 0: Off 1: On
1.3.6.1.4.1.4756.20.501.20.1.1582ColumnnidPort6VlanIngressAcceptanceRemoteAread-writecurrentNID Series card Port VLAN Configuration : Port6 - Ingress Acceptance 0: Tagged and untagged 1: Tagged only 2: Untagged only
1.3.6.1.4.1.4756.20.501.20.1.1583ColumnnidPort6VlanEgressTaggingRemoteAread-writecurrentNID Series card Port VLAN Configuration : Port6 - Egress Tagging 0: Untag port vlan 1: Tag all 2: Untag all
1.3.6.1.4.1.4756.20.501.20.1.1584ColumnnidPort6AllowedVLANSRemoteAread-writecurrentNID Series card Global VLAN Configuration: Port6 - Allowed VLANs By default, only VLAN 1 is enabled. More VLANs may be created by using a list syntax where the…
1.3.6.1.4.1.4756.20.501.20.1.1585ColumnnidPort6ForbiddenVLANSRemoteAread-writecurrentNID Series card Global VLAN Configuration: Port6 - Forbidden VLANs By default, the field is left blank, which means that the port may become a member of all po…
1.3.6.1.4.1.4756.20.501.20.1.1586ColumnnidPort7VlanModeRemoteAread-writecurrentNID Series card Port VLAN Configuration : Port7 - Mode 0: Access 1: Trunk 2: Hybrid
1.3.6.1.4.1.4756.20.501.20.1.1587ColumnnidPort7VlanIDRemoteAread-writecurrentNID Series card Port VLAN Configuration : Port7 - VLAN ID
1.3.6.1.4.1.4756.20.501.20.1.1588ColumnnidPort7VlanTypeRemoteAread-writecurrentNID Series card Port VLAN Configuration : Port7 - VLAN Type 0: Unaware 1: C-port 2: S-port 3: S-custom-port
1.3.6.1.4.1.4756.20.501.20.1.1589ColumnnidPort7VlanIngressFilteringRemoteAread-writecurrentNID Series card Port VLAN Configuration : Port7 - Ingress Filtering 0: Off 1: On
1.3.6.1.4.1.4756.20.501.20.1.1590ColumnnidPort7VlanIngressAcceptanceRemoteAread-writecurrentNID Series card Port VLAN Configuration : Port7 - Ingress Acceptance 0: Tagged and untagged 1: Tagged only 2: Untagged only
1.3.6.1.4.1.4756.20.501.20.1.1591ColumnnidPort7VlanEgressTaggingRemoteAread-writecurrentNID Series card Port VLAN Configuration : Port7 - Egress Tagging 0: Untag port vlan 1: Tag all 2: Untag all
1.3.6.1.4.1.4756.20.501.20.1.1592ColumnnidPort7AllowedVLANSRemoteAread-writecurrentNID Series card Global VLAN Configuration: Port7 - Allowed VLANs By default, only VLAN 1 is enabled. More VLANs may be created by using a list syntax where the…
1.3.6.1.4.1.4756.20.501.20.1.1593ColumnnidPort7ForbiddenVLANSRemoteAread-writecurrentNID Series card Global VLAN Configuration: Port7 - Forbidden VLANs By default, the field is left blank, which means that the port may become a member of all po…
1.3.6.1.4.1.4756.20.501.20.1.1594ColumnnidPort8VlanModeRemoteAread-writecurrentNID Series card Port VLAN Configuration : Port8 - Mode 0: Access 1: Trunk 2: Hybrid
1.3.6.1.4.1.4756.20.501.20.1.1595ColumnnidPort8VlanIDRemoteAread-writecurrentNID Series card Port VLAN Configuration : Port8 - VLAN ID
1.3.6.1.4.1.4756.20.501.20.1.1596ColumnnidPort8VlanTypeRemoteAread-writecurrentNID Series card Port VLAN Configuration : Port8 - VLAN Type 0: Unaware 1: C-port 2: S-port 3: S-custom-port
1.3.6.1.4.1.4756.20.501.20.1.1597ColumnnidPort8VlanIngressFilteringRemoteAread-writecurrentNID Series card Port VLAN Configuration : Port8 - Ingress Filtering 0: Off 1: On
1.3.6.1.4.1.4756.20.501.20.1.1598ColumnnidPort8VlanIngressAcceptanceRemoteAread-writecurrentNID Series card Port VLAN Configuration : Port8 - Ingress Acceptance 0: Tagged and untagged 1: Tagged only 2: Untagged only
1.3.6.1.4.1.4756.20.501.20.1.1599ColumnnidPort8VlanEgressTaggingRemoteAread-writecurrentNID Series card Port VLAN Configuration : Port8 - Egress Tagging 0: Untag port vlan 1: Tag all 2: Untag all
1.3.6.1.4.1.4756.20.501.20.1.1600ColumnnidPort8AllowedVLANSRemoteAread-writecurrentNID Series card Global VLAN Configuration: Port8 - Allowed VLANs By default, only VLAN 1 is enabled. More VLANs may be created by using a list syntax where the…
1.3.6.1.4.1.4756.20.501.20.1.1601ColumnnidPort8ForbiddenVLANSRemoteAread-writecurrentNID Series card Global VLAN Configuration: Port8 - Forbidden VLANs By default, the field is left blank, which means that the port may become a member of all po…
1.3.6.1.4.1.4756.20.501.20.1.1602ColumnnidQOSPort1IngressRemoteAread-writecurrentNID Series card QOS Port1 Ingress Enabled 0: NO 1: YES
1.3.6.1.4.1.4756.20.501.20.1.1603ColumnnidQOSPort1IngressRateRemoteAread-writecurrentNID Series card QOS Port1 Ingress Rate
1.3.6.1.4.1.4756.20.501.20.1.1604ColumnnidQOSPort1IngressRateUnitRemoteAread-writecurrentNID Series card QOS Port1 Ingress Rate Unit 0: Kbps 1: Mbps 2: fps 3: kfps
1.3.6.1.4.1.4756.20.501.20.1.1605ColumnnidQOSPort1IngressFlowControlRemoteAread-writecurrentNID Series card QOS Port1 Ingress Flow Control 0: NO 1: YES
1.3.6.1.4.1.4756.20.501.20.1.1606ColumnnidQOSPort2IngressRemoteAread-writecurrentNID Series card QOS Port2 Ingress Enabled 0: NO 1: YES
1.3.6.1.4.1.4756.20.501.20.1.1607ColumnnidQOSPort2IngressRateRemoteAread-writecurrentNID Series card QOS Port2 Ingress Rate
1.3.6.1.4.1.4756.20.501.20.1.1608ColumnnidQOSPort2IngressRateUnitRemoteAread-writecurrentNID Series card QOS Port2 Ingress Rate Unit 0: Kbps 1: Mbps 2: fps 3: kfps
1.3.6.1.4.1.4756.20.501.20.1.1609ColumnnidQOSPort2IngressFlowControlRemoteAread-writecurrentNID Series card QOS Port2 Ingress Flow Control 0: NO 1: YES
1.3.6.1.4.1.4756.20.501.20.1.1610ColumnnidQOSPort3IngressRemoteAread-writecurrentNID Series card QOS Port3 Ingress Enabled 0: NO 1: YES
1.3.6.1.4.1.4756.20.501.20.1.1611ColumnnidQOSPort3IngressRateRemoteAread-writecurrentNID Series card QOS Port3 Ingress Rate
1.3.6.1.4.1.4756.20.501.20.1.1612ColumnnidQOSPort3IngressRateUnitRemoteAread-writecurrentNID Series card QOS Port3 Ingress Rate Unit 0: Kbps 1: Mbps 2: fps 3: kfps
1.3.6.1.4.1.4756.20.501.20.1.1613ColumnnidQOSPort3IngressFlowControlRemoteAread-writecurrentNID Series card QOS Port3 Ingress Flow Control 0: NO 1: YES
1.3.6.1.4.1.4756.20.501.20.1.1614ColumnnidQOSPort4IngressRemoteAread-writecurrentNID Series card QOS Port4 Ingress Enabled 0: NO 1: YES
1.3.6.1.4.1.4756.20.501.20.1.1615ColumnnidQOSPort4IngressRateRemoteAread-writecurrentNID Series card QOS Port4 Ingress Rate
1.3.6.1.4.1.4756.20.501.20.1.1616ColumnnidQOSPort4IngressRateUnitRemoteAread-writecurrentNID Series card QOS Port4 Ingress Rate Unit 0: Kbps 1: Mbps 2: fps 3: kfps
1.3.6.1.4.1.4756.20.501.20.1.1617ColumnnidQOSPort4IngressFlowControlRemoteAread-writecurrentNID Series card QOS Port4 Ingress Flow Control 0: NO 1: YES
1.3.6.1.4.1.4756.20.501.20.1.1618ColumnnidQOSPort5IngressRemoteAread-writecurrentNID Series card QOS Port5 Ingress Enabled 0: NO 1: YES
1.3.6.1.4.1.4756.20.501.20.1.1619ColumnnidQOSPort5IngressRateRemoteAread-writecurrentNID Series card QOS Port5 Ingress Rate
1.3.6.1.4.1.4756.20.501.20.1.1620ColumnnidQOSPort5IngressRateUnitRemoteAread-writecurrentNID Series card QOS Port5 Ingress Rate Unit 0: Kbps 1: Mbps 2: fps 3: kfps
1.3.6.1.4.1.4756.20.501.20.1.1621ColumnnidQOSPort5IngressFlowControlRemoteAread-writecurrentNID Series card QOS Port5 Ingress Flow Control 0: NO 1: YES
1.3.6.1.4.1.4756.20.501.20.1.1622ColumnnidQOSPort6IngressRemoteAread-writecurrentNID Series card QOS Port6 Ingress Enabled 0: NO 1: YES
1.3.6.1.4.1.4756.20.501.20.1.1623ColumnnidQOSPort6IngressRateRemoteAread-writecurrentNID Series card QOS Port6 Ingress Rate
1.3.6.1.4.1.4756.20.501.20.1.1624ColumnnidQOSPort6IngressRateUnitRemoteAread-writecurrentNID Series card QOS Port6 Ingress Rate Unit 0: Kbps 1: Mbps 2: fps 3: kfps
1.3.6.1.4.1.4756.20.501.20.1.1625ColumnnidQOSPort6IngressFlowControlRemoteAread-writecurrentNID Series card QOS Port6 Ingress Flow Control 0: NO 1: YES
1.3.6.1.4.1.4756.20.501.20.1.1626ColumnnidQOSPort7IngressRemoteAread-writecurrentNID Series card QOS Port7 Ingress Enabled 0: NO 1: YES
1.3.6.1.4.1.4756.20.501.20.1.1627ColumnnidQOSPort7IngressRateRemoteAread-writecurrentNID Series card QOS Port7 Ingress Rate
1.3.6.1.4.1.4756.20.501.20.1.1628ColumnnidQOSPort7IngressRateUnitRemoteAread-writecurrentNID Series card QOS Port7 Ingress Rate Unit 0: Kbps 1: Mbps 2: fps 3: kfps
1.3.6.1.4.1.4756.20.501.20.1.1629ColumnnidQOSPort7IngressFlowControlRemoteAread-writecurrentNID Series card QOS Port7 Ingress Flow Control 0: NO 1: YES
1.3.6.1.4.1.4756.20.501.20.1.1630ColumnnidQOSPort8IngressRemoteAread-writecurrentNID Series card QOS Port8 Ingress Enabled 0: NO 1: YES
1.3.6.1.4.1.4756.20.501.20.1.1631ColumnnidQOSPort8IngressRateRemoteAread-writecurrentNID Series card QOS Port8 Ingress Rate
1.3.6.1.4.1.4756.20.501.20.1.1632ColumnnidQOSPort8IngressRateUnitRemoteAread-writecurrentNID Series card QOS Port8 Ingress Rate Unit 0: Kbps 1: Mbps 2: fps 3: kfps
1.3.6.1.4.1.4756.20.501.20.1.1633ColumnnidQOSPort8IngressFlowControlRemoteAread-writecurrentNID Series card QOS Port8 Ingress Flow Control 0: NO 1: YES
1.3.6.1.4.1.4756.20.501.20.1.1634ColumnnidQOSPort1EgressRemoteAread-writecurrentNID Series card QOS Port1 Egress Enabled 0: NO 1: YES
1.3.6.1.4.1.4756.20.501.20.1.1635ColumnnidQOSPort1EgressRateRemoteAread-writecurrentNID Series card QOS Port1 Egress Rate
1.3.6.1.4.1.4756.20.501.20.1.1636ColumnnidQOSPort1EgressRateUnitRemoteAread-writecurrentNID Series card QOS Port1 Egress Rate Unit 0: Kbps 1: Mbps
1.3.6.1.4.1.4756.20.501.20.1.1637ColumnnidQOSPort2EgressRemoteAread-writecurrentNID Series card QOS Port2 Egress Enabled 0: NO 1: YES
1.3.6.1.4.1.4756.20.501.20.1.1638ColumnnidQOSPort2EgressRateRemoteAread-writecurrentNID Series card QOS Port2 Egress Rate
1.3.6.1.4.1.4756.20.501.20.1.1639ColumnnidQOSPort2EgressRateUnitRemoteAread-writecurrentNID Series card QOS Port2 Egress Rate Unit 0: Kbps 1: Mbps
1.3.6.1.4.1.4756.20.501.20.1.1640ColumnnidQOSPort3EgressRemoteAread-writecurrentNID Series card QOS Port3 Egress Enabled 0: NO 1: YES
1.3.6.1.4.1.4756.20.501.20.1.1641ColumnnidQOSPort3EgressRateRemoteAread-writecurrentNID Series card QOS Port3 Egress Rate
1.3.6.1.4.1.4756.20.501.20.1.1642ColumnnidQOSPort3EgressRateUnitRemoteAread-writecurrentNID Series card QOS Port3 Egress Rate Unit 0: Kbps 1: Mbps
1.3.6.1.4.1.4756.20.501.20.1.1643ColumnnidQOSPort4EgressRemoteAread-writecurrentNID Series card QOS Port4 Egress Enabled 0: NO 1: YES
1.3.6.1.4.1.4756.20.501.20.1.1644ColumnnidQOSPort4EgressRateRemoteAread-writecurrentNID Series card QOS Port4 Egress Rate
1.3.6.1.4.1.4756.20.501.20.1.1645ColumnnidQOSPort4EgressRateUnitRemoteAread-writecurrentNID Series card QOS Port4 Egress Rate Unit 0: Kbps 1: Mbps
1.3.6.1.4.1.4756.20.501.20.1.1646ColumnnidQOSPort5EgressRemoteAread-writecurrentNID Series card QOS Port5 Egress Enabled 0: NO 1: YES
1.3.6.1.4.1.4756.20.501.20.1.1647ColumnnidQOSPort5EgressRateRemoteAread-writecurrentNID Series card QOS Port5 Egress Rate
1.3.6.1.4.1.4756.20.501.20.1.1648ColumnnidQOSPort5EgressRateUnitRemoteAread-writecurrentNID Series card QOS Port5 Egress Rate Unit 0: Kbps 1: Mbps
1.3.6.1.4.1.4756.20.501.20.1.1649ColumnnidQOSPort6EgressRemoteAread-writecurrentNID Series card QOS Port6 Egress Enabled 0: NO 1: YES
1.3.6.1.4.1.4756.20.501.20.1.1650ColumnnidQOSPort6EgressRateRemoteAread-writecurrentNID Series card QOS Port6 Egress Rate
1.3.6.1.4.1.4756.20.501.20.1.1651ColumnnidQOSPort6EgressRateUnitRemoteAread-writecurrentNID Series card QOS Port6 Egress Rate Unit 0: Kbps 1: Mbps
1.3.6.1.4.1.4756.20.501.20.1.1652ColumnnidQOSPort7EgressRemoteAread-writecurrentNID Series card QOS Port7 Egress Enabled 0: NO 1: YES
1.3.6.1.4.1.4756.20.501.20.1.1653ColumnnidQOSPort7EgressRateRemoteAread-writecurrentNID Series card QOS Port7 Egress Rate
1.3.6.1.4.1.4756.20.501.20.1.1654ColumnnidQOSPort7EgressRateUnitRemoteAread-writecurrentNID Series card QOS Port7 Egress Rate Unit 0: Kbps 1: Mbps
1.3.6.1.4.1.4756.20.501.20.1.1655ColumnnidQOSPort8EgressRemoteAread-writecurrentNID Series card QOS Port8 Egress Enabled 0: NO 1: YES
1.3.6.1.4.1.4756.20.501.20.1.1656ColumnnidQOSPort8EgressRateRemoteAread-writecurrentNID Series card QOS Port8 Egress Rate
1.3.6.1.4.1.4756.20.501.20.1.1657ColumnnidQOSPort8EgressRateUnitRemoteAread-writecurrentNID Series card QOS Port8 Egress Rate Unit 0: Kbps 1: Mbps
1.3.6.1.4.1.4756.20.501.20.1.1658ColumnnidQOSUnicastRemoteAread-writecurrentNID Series card QOS Storm Control Configuration- Unicast 0: NO 1: YES
1.3.6.1.4.1.4756.20.501.20.1.1659ColumnnidQOSUnicastRateRemoteAread-writecurrentNID Series card QOS Storm Control Configuration- Unicast Rate The rate unit is packets per second (pps). 0: 1 1: 2 2: 4 3: 8 4: 16 5: 32 6: 64 7: 128 8: 256 9:…
1.3.6.1.4.1.4756.20.501.20.1.1660ColumnnidQOSMulticastRemoteAread-writecurrentNID Series card QOS Storm Control Configuration- Multicast 0: NO 1: YES
1.3.6.1.4.1.4756.20.501.20.1.1661ColumnnidQOSMulticastRateRemoteAread-writecurrentNID Series card QOS Storm Control Configuration- Multicast The rate unit is packets per second (pps). 0: 1 1: 2 2: 4 3: 8 4: 16 5: 32 6: 64 7: 128 8: 256 9: 51…
1.3.6.1.4.1.4756.20.501.20.1.1662ColumnnidQOSBroadcastRemoteAread-writecurrentNID Series card QOS Storm Control Configuration- Broadcast 0: NO 1: YES
1.3.6.1.4.1.4756.20.501.20.1.1663ColumnnidQOSBroadcastRateRemoteAread-writecurrentNID Series card QOS Storm Control Configuration- Broadcast The rate unit is packets per second (pps). 0: 1 1: 2 2: 4 3: 8 4: 16 5: 32 6: 64 7: 128 8: 256 9: 51…
1.3.6.1.4.1.4756.20.501.20.1.1664ColumnnidL2CPPort1DMAC0180C2000000RemoteAread-writecurrentNID Series card Port 1 L2CP Mode 0180C2000000 0: Forward 1: Discard 2: Peer
1.3.6.1.4.1.4756.20.501.20.1.1665ColumnnidL2CPPort1DMAC0180C2000001RemoteAread-writecurrentNID Series card Port 1 L2CP Mode 0180C2000001 0: Forward 1: Discard 2: Peer
1.3.6.1.4.1.4756.20.501.20.1.1666ColumnnidL2CPPort1DMAC0180C2000002RemoteAread-writecurrentNID Series card Port 1 L2CP Mode 0180C2000002 0: Forward 1: Discard 2: Peer
1.3.6.1.4.1.4756.20.501.20.1.1667ColumnnidL2CPPort1DMAC0180C2000003RemoteAread-writecurrentNID Series card Port 1 L2CP Mode 0180C2000003 0: Forward 1: Discard 2: Peer
1.3.6.1.4.1.4756.20.501.20.1.1668ColumnnidL2CPPort1DMAC0180C2000004RemoteAread-writecurrentNID Series card Port 1 L2CP Mode 0180C2000004 0: Forward 1: Discard 2: Peer
1.3.6.1.4.1.4756.20.501.20.1.1669ColumnnidL2CPPort1DMAC0180C2000005RemoteAread-writecurrentNID Series card Port 1 L2CP Mode 0180C2000005 0: Forward 1: Discard 2: Peer
1.3.6.1.4.1.4756.20.501.20.1.1670ColumnnidL2CPPort1DMAC0180C2000006RemoteAread-writecurrentNID Series card Port 1 L2CP Mode 0180C2000006 0: Forward 1: Discard 2: Peer
1.3.6.1.4.1.4756.20.501.20.1.1671ColumnnidL2CPPort1DMAC0180C2000007RemoteAread-writecurrentNID Series card Port 1 L2CP Mode 0180C2000007 0: Forward 1: Discard 2: Peer
1.3.6.1.4.1.4756.20.501.20.1.1672ColumnnidL2CPPort1DMAC0180C2000008RemoteAread-writecurrentNID Series card Port 1 L2CP Mode 0180C2000008 0: Forward 1: Discard 2: Peer
1.3.6.1.4.1.4756.20.501.20.1.1673ColumnnidL2CPPort1DMAC0180C2000009RemoteAread-writecurrentNID Series card Port 1 L2CP Mode 0180C2000009 0: Forward 1: Discard 2: Peer
1.3.6.1.4.1.4756.20.501.20.1.1674ColumnnidL2CPPort1DMAC0180C200000ARemoteAread-writecurrentNID Series card Port 1 L2CP Mode 0180C200000A 0: Forward 1: Discard 2: Peer
1.3.6.1.4.1.4756.20.501.20.1.1675ColumnnidL2CPPort1DMAC0180C200000BRemoteAread-writecurrentNID Series card Port 1 L2CP Mode 0180C200000B 0: Forward 1: Discard 2: Peer
1.3.6.1.4.1.4756.20.501.20.1.1676ColumnnidL2CPPort1DMAC0180C200000CRemoteAread-writecurrentNID Series card Port 1 L2CP Mode 0180C200000C 0: Forward 1: Discard 2: Peer
1.3.6.1.4.1.4756.20.501.20.1.1677ColumnnidL2CPPort1DMAC0180C200000DRemoteAread-writecurrentNID Series card Port 1 L2CP Mode 0180C200000D 0: Forward 1: Discard 2: Peer
1.3.6.1.4.1.4756.20.501.20.1.1678ColumnnidL2CPPort1DMAC0180C200000ERemoteAread-writecurrentNID Series card Port 1 L2CP Mode 0180C200000E 0: Forward 1: Discard 2: Peer
1.3.6.1.4.1.4756.20.501.20.1.1679ColumnnidL2CPPort1DMAC0180C200000FRemoteAread-writecurrentNID Series card Port 1 L2CP Mode 0180C200000F 0: Forward 1: Discard 2: Peer
1.3.6.1.4.1.4756.20.501.20.1.1680ColumnnidL2CPPort1DMAC0180C2000010RemoteAread-writecurrentNID Series card Port 1 L2CP Mode 0180C2000010 0: Forward 1: Discard 2: Peer
1.3.6.1.4.1.4756.20.501.20.1.1681ColumnnidL2CPPort1DMAC0180C2000020RemoteAread-writecurrentNID Series card Port 1 L2CP Mode 0180C2000020 0: Forward 1: Discard 2: Peer
1.3.6.1.4.1.4756.20.501.20.1.1682ColumnnidL2CPPort1DMAC0180C2000021RemoteAread-writecurrentNID Series card Port 1 L2CP Mode 0180C2000021 0: Forward 1: Discard 2: Peer
1.3.6.1.4.1.4756.20.501.20.1.1683ColumnnidL2CPPort1DMAC0180C2000022RemoteAread-writecurrentNID Series card Port 1 L2CP Mode 0180C2000022 0: Forward 1: Discard 2: Peer
1.3.6.1.4.1.4756.20.501.20.1.1684ColumnnidL2CPPort1DMAC0180C2000023RemoteAread-writecurrentNID Series card Port 1 L2CP Mode 0180C2000023 0: Forward 1: Discard 2: Peer
1.3.6.1.4.1.4756.20.501.20.1.1685ColumnnidL2CPPort1DMAC0180C2000024RemoteAread-writecurrentNID Series card Port 1 L2CP Mode 0180C2000024 0: Forward 1: Discard 2: Peer
1.3.6.1.4.1.4756.20.501.20.1.1686ColumnnidL2CPPort1DMAC0180C2000025RemoteAread-writecurrentNID Series card Port 1 L2CP Mode 0180C2000025 0: Forward 1: Discard 2: Peer
1.3.6.1.4.1.4756.20.501.20.1.1687ColumnnidL2CPPort1DMAC0180C2000026RemoteAread-writecurrentNID Series card Port 1 L2CP Mode 0180C2000026 0: Forward 1: Discard 2: Peer
1.3.6.1.4.1.4756.20.501.20.1.1688ColumnnidL2CPPort1DMAC0180C2000027RemoteAread-writecurrentNID Series card Port 1 L2CP Mode 0180C2000027 0: Forward 1: Discard 2: Peer
1.3.6.1.4.1.4756.20.501.20.1.1689ColumnnidL2CPPort1DMAC0180C2000028RemoteAread-writecurrentNID Series card Port 1 L2CP Mode 0180C2000028 0: Forward 1: Discard 2: Peer
1.3.6.1.4.1.4756.20.501.20.1.1690ColumnnidL2CPPort1DMAC0180C2000029RemoteAread-writecurrentNID Series card Port 1 L2CP Mode 0180C2000029 0: Forward 1: Discard 2: Peer
1.3.6.1.4.1.4756.20.501.20.1.1691ColumnnidL2CPPort1DMAC0180C200002ARemoteAread-writecurrentNID Series card Port 1 L2CP Mode 0180C200002A 0: Forward 1: Discard 2: Peer
1.3.6.1.4.1.4756.20.501.20.1.1692ColumnnidL2CPPort1DMAC0180C200002BRemoteAread-writecurrentNID Series card Port 1 L2CP Mode 0180C200002B 0: Forward 1: Discard 2: Peer
1.3.6.1.4.1.4756.20.501.20.1.1693ColumnnidL2CPPort1DMAC0180C200002CRemoteAread-writecurrentNID Series card Port 1 L2CP Mode 0180C200002C 0: Forward 1: Discard 2: Peer
1.3.6.1.4.1.4756.20.501.20.1.1694ColumnnidL2CPPort1DMAC0180C200002DRemoteAread-writecurrentNID Series card Port 1 L2CP Mode 0180C200002D 0: Forward 1: Discard 2: Peer
1.3.6.1.4.1.4756.20.501.20.1.1695ColumnnidL2CPPort1DMAC0180C200002ERemoteAread-writecurrentNID Series card Port 1 L2CP Mode 0180C200002E 0: Forward 1: Discard 2: Peer
1.3.6.1.4.1.4756.20.501.20.1.1696ColumnnidL2CPPort1DMAC0180C200002FRemoteAread-writecurrentNID Series card Port 1 L2CP Mode 0180C200002F 0: Forward 1: Discard 1: Peer
1.3.6.1.4.1.4756.20.501.20.1.1697ColumnnidL2CPPort2DMAC0180C2000000RemoteAread-writecurrentNID Series card Port 2 L2CP Mode 0180C2000000 0: Forward 1: Discard 2: Peer
1.3.6.1.4.1.4756.20.501.20.1.1698ColumnnidL2CPPort2DMAC0180C2000001RemoteAread-writecurrentNID Series card Port 2 L2CP Mode 0180C2000001 0: Forward 1: Discard 2: Peer
1.3.6.1.4.1.4756.20.501.20.1.1699ColumnnidL2CPPort2DMAC0180C2000002RemoteAread-writecurrentNID Series card Port 2 L2CP Mode 0180C2000002 0: Forward 1: Discard 2: Peer
1.3.6.1.4.1.4756.20.501.20.1.1700ColumnnidL2CPPort2DMAC0180C2000003RemoteAread-writecurrentNID Series card Port 2 L2CP Mode 0180C2000003 0: Forward 1: Discard 2: Peer
1.3.6.1.4.1.4756.20.501.20.1.1701ColumnnidL2CPPort2DMAC0180C2000004RemoteAread-writecurrentNID Series card Port 2 L2CP Mode 0180C2000004 0: Forward 1: Discard 2: Peer
1.3.6.1.4.1.4756.20.501.20.1.1702ColumnnidL2CPPort2DMAC0180C2000005RemoteAread-writecurrentNID Series card Port 2 L2CP Mode 0180C2000005 0: Forward 1: Discard 2: Peer
1.3.6.1.4.1.4756.20.501.20.1.1703ColumnnidL2CPPort2DMAC0180C2000006RemoteAread-writecurrentNID Series card Port 2 L2CP Mode 0180C2000006 0: Forward 1: Discard 2: Peer
1.3.6.1.4.1.4756.20.501.20.1.1704ColumnnidL2CPPort2DMAC0180C2000007RemoteAread-writecurrentNID Series card Port 2 L2CP Mode 0180C2000007 0: Forward 1: Discard 2: Peer
1.3.6.1.4.1.4756.20.501.20.1.1705ColumnnidL2CPPort2DMAC0180C2000008RemoteAread-writecurrentNID Series card Port 2 L2CP Mode 0180C2000008 0: Forward 1: Discard 2: Peer
1.3.6.1.4.1.4756.20.501.20.1.1706ColumnnidL2CPPort2DMAC0180C2000009RemoteAread-writecurrentNID Series card Port 2 L2CP Mode 0180C2000009 0: Forward 1: Discard 2: Peer
1.3.6.1.4.1.4756.20.501.20.1.1707ColumnnidL2CPPort2DMAC0180C200000ARemoteAread-writecurrentNID Series card Port 2 L2CP Mode 0180C200000A 0: Forward 1: Discard 2: Peer
1.3.6.1.4.1.4756.20.501.20.1.1708ColumnnidL2CPPort2DMAC0180C200000BRemoteAread-writecurrentNID Series card Port 2 L2CP Mode 0180C200000B 0: Forward 1: Discard 2: Peer
1.3.6.1.4.1.4756.20.501.20.1.1709ColumnnidL2CPPort2DMAC0180C200000CRemoteAread-writecurrentNID Series card Port 2 L2CP Mode 0180C200000C 0: Forward 1: Discard 2: Peer
1.3.6.1.4.1.4756.20.501.20.1.1710ColumnnidL2CPPort2DMAC0180C200000DRemoteAread-writecurrentNID Series card Port 2 L2CP Mode 0180C200000D 0: Forward 1: Discard 2: Peer
1.3.6.1.4.1.4756.20.501.20.1.1711ColumnnidL2CPPort2DMAC0180C200000ERemoteAread-writecurrentNID Series card Port 2 L2CP Mode 0180C200000E 0: Forward 1: Discard 2: Peer
1.3.6.1.4.1.4756.20.501.20.1.1712ColumnnidL2CPPort2DMAC0180C200000FRemoteAread-writecurrentNID Series card Port 2 L2CP Mode 0180C200000F 0: Forward 1: Discard 2: Peer
1.3.6.1.4.1.4756.20.501.20.1.1713ColumnnidL2CPPort2DMAC0180C2000010RemoteAread-writecurrentNID Series card Port 2 L2CP Mode 0180C2000010 0: Forward 1: Discard 2: Peer
1.3.6.1.4.1.4756.20.501.20.1.1714ColumnnidL2CPPort2DMAC0180C2000020RemoteAread-writecurrentNID Series card Port 2 L2CP Mode 0180C2000020 0: Forward 1: Discard 2: Peer
1.3.6.1.4.1.4756.20.501.20.1.1715ColumnnidL2CPPort2DMAC0180C2000021RemoteAread-writecurrentNID Series card Port 2 L2CP Mode 0180C2000021 0: Forward 1: Discard 2: Peer
1.3.6.1.4.1.4756.20.501.20.1.1716ColumnnidL2CPPort2DMAC0180C2000022RemoteAread-writecurrentNID Series card Port 2 L2CP Mode 0180C2000022 0: Forward 1: Discard 2: Peer
1.3.6.1.4.1.4756.20.501.20.1.1717ColumnnidL2CPPort2DMAC0180C2000023RemoteAread-writecurrentNID Series card Port 2 L2CP Mode 0180C2000023 0: Forward 1: Discard 2: Peer
1.3.6.1.4.1.4756.20.501.20.1.1718ColumnnidL2CPPort2DMAC0180C2000024RemoteAread-writecurrentNID Series card Port 2 L2CP Mode 0180C2000024 0: Forward 1: Discard 2: Peer
1.3.6.1.4.1.4756.20.501.20.1.1719ColumnnidL2CPPort2DMAC0180C2000025RemoteAread-writecurrentNID Series card Port 2 L2CP Mode 0180C2000025 0: Forward 1: Discard 2: Peer
1.3.6.1.4.1.4756.20.501.20.1.1720ColumnnidL2CPPort2DMAC0180C2000026RemoteAread-writecurrentNID Series card Port 2 L2CP Mode 0180C2000026 0: Forward 1: Discard 2: Peer
1.3.6.1.4.1.4756.20.501.20.1.1721ColumnnidL2CPPort2DMAC0180C2000027RemoteAread-writecurrentNID Series card Port 2 L2CP Mode 0180C2000027 0: Forward 1: Discard 2: Peer
1.3.6.1.4.1.4756.20.501.20.1.1722ColumnnidL2CPPort2DMAC0180C2000028RemoteAread-writecurrentNID Series card Port 2 L2CP Mode 0180C2000028 0: Forward 1: Discard 2: Peer
1.3.6.1.4.1.4756.20.501.20.1.1723ColumnnidL2CPPort2DMAC0180C2000029RemoteAread-writecurrentNID Series card Port 2 L2CP Mode 0180C2000029 0: Forward 1: Discard 2: Peer
1.3.6.1.4.1.4756.20.501.20.1.1724ColumnnidL2CPPort2DMAC0180C200002ARemoteAread-writecurrentNID Series card Port 2 L2CP Mode 0180C200002A 0: Forward 1: Discard 2: Peer
1.3.6.1.4.1.4756.20.501.20.1.1725ColumnnidL2CPPort2DMAC0180C200002BRemoteAread-writecurrentNID Series card Port 2 L2CP Mode 0180C200002B 0: Forward 1: Discard 2: Peer
1.3.6.1.4.1.4756.20.501.20.1.1726ColumnnidL2CPPort2DMAC0180C200002CRemoteAread-writecurrentNID Series card Port 2 L2CP Mode 0180C200002C 0: Forward 1: Discard 2: Peer
1.3.6.1.4.1.4756.20.501.20.1.1727ColumnnidL2CPPort2DMAC0180C200002DRemoteAread-writecurrentNID Series card Port 2 L2CP Mode 0180C200002D 0: Forward 1: Discard 2: Peer
1.3.6.1.4.1.4756.20.501.20.1.1728ColumnnidL2CPPort2DMAC0180C200002ERemoteAread-writecurrentNID Series card Port 2 L2CP Mode 0180C200002E 0: Forward 1: Discard 2: Peer
1.3.6.1.4.1.4756.20.501.20.1.1729ColumnnidL2CPPort2DMAC0180C200002FRemoteAread-writecurrentNID Series card Port 2 L2CP Mode 0180C200002F 0: Forward 1: Discard 1: Peer
1.3.6.1.4.1.4756.20.501.20.1.1730ColumnnidL2CPPort3DMAC0180C2000000RemoteAread-writecurrentNID Series card Port 3 L2CP Mode 0180C2000000 0: Forward 1: Discard 2: Peer
1.3.6.1.4.1.4756.20.501.20.1.1731ColumnnidL2CPPort3DMAC0180C2000001RemoteAread-writecurrentNID Series card Port 3 L2CP Mode 0180C2000001 0: Forward 1: Discard 2: Peer
1.3.6.1.4.1.4756.20.501.20.1.1732ColumnnidL2CPPort3DMAC0180C2000002RemoteAread-writecurrentNID Series card Port 3 L2CP Mode 0180C2000002 0: Forward 1: Discard 2: Peer
1.3.6.1.4.1.4756.20.501.20.1.1733ColumnnidL2CPPort3DMAC0180C2000003RemoteAread-writecurrentNID Series card Port 3 L2CP Mode 0180C2000003 0: Forward 1: Discard 2: Peer
1.3.6.1.4.1.4756.20.501.20.1.1734ColumnnidL2CPPort3DMAC0180C2000004RemoteAread-writecurrentNID Series card Port 3 L2CP Mode 0180C2000004 0: Forward 1: Discard 2: Peer
1.3.6.1.4.1.4756.20.501.20.1.1735ColumnnidL2CPPort3DMAC0180C2000005RemoteAread-writecurrentNID Series card Port 3 L2CP Mode 0180C2000005 0: Forward 1: Discard 2: Peer
1.3.6.1.4.1.4756.20.501.20.1.1736ColumnnidL2CPPort3DMAC0180C2000006RemoteAread-writecurrentNID Series card Port 3 L2CP Mode 0180C2000006 0: Forward 1: Discard 2: Peer
1.3.6.1.4.1.4756.20.501.20.1.1737ColumnnidL2CPPort3DMAC0180C2000007RemoteAread-writecurrentNID Series card Port 3 L2CP Mode 0180C2000007 0: Forward 1: Discard 2: Peer
1.3.6.1.4.1.4756.20.501.20.1.1738ColumnnidL2CPPort3DMAC0180C2000008RemoteAread-writecurrentNID Series card Port 3 L2CP Mode 0180C2000008 0: Forward 1: Discard 2: Peer
1.3.6.1.4.1.4756.20.501.20.1.1739ColumnnidL2CPPort3DMAC0180C2000009RemoteAread-writecurrentNID Series card Port 3 L2CP Mode 0180C2000009 0: Forward 1: Discard 2: Peer
1.3.6.1.4.1.4756.20.501.20.1.1740ColumnnidL2CPPort3DMAC0180C200000ARemoteAread-writecurrentNID Series card Port 3 L2CP Mode 0180C200000A 0: Forward 1: Discard 2: Peer
1.3.6.1.4.1.4756.20.501.20.1.1741ColumnnidL2CPPort3DMAC0180C200000BRemoteAread-writecurrentNID Series card Port 3 L2CP Mode 0180C200000B 0: Forward 1: Discard 2: Peer
1.3.6.1.4.1.4756.20.501.20.1.1742ColumnnidL2CPPort3DMAC0180C200000CRemoteAread-writecurrentNID Series card Port 3 L2CP Mode 0180C200000C 0: Forward 1: Discard 2: Peer
1.3.6.1.4.1.4756.20.501.20.1.1743ColumnnidL2CPPort3DMAC0180C200000DRemoteAread-writecurrentNID Series card Port 3 L2CP Mode 0180C200000D 0: Forward 1: Discard 2: Peer
1.3.6.1.4.1.4756.20.501.20.1.1744ColumnnidL2CPPort3DMAC0180C200000ERemoteAread-writecurrentNID Series card Port 3 L2CP Mode 0180C200000E 0: Forward 1: Discard 2: Peer
1.3.6.1.4.1.4756.20.501.20.1.1745ColumnnidL2CPPort3DMAC0180C200000FRemoteAread-writecurrentNID Series card Port 3 L2CP Mode 0180C200000F 0: Forward 1: Discard 2: Peer
1.3.6.1.4.1.4756.20.501.20.1.1746ColumnnidL2CPPort3DMAC0180C2000010RemoteAread-writecurrentNID Series card Port 3 L2CP Mode 0180C2000010 0: Forward 1: Discard 2: Peer
1.3.6.1.4.1.4756.20.501.20.1.1747ColumnnidL2CPPort3DMAC0180C2000020RemoteAread-writecurrentNID Series card Port 3 L2CP Mode 0180C2000020 0: Forward 1: Discard 2: Peer
1.3.6.1.4.1.4756.20.501.20.1.1748ColumnnidL2CPPort3DMAC0180C2000021RemoteAread-writecurrentNID Series card Port 3 L2CP Mode 0180C2000021 0: Forward 1: Discard 2: Peer
1.3.6.1.4.1.4756.20.501.20.1.1749ColumnnidL2CPPort3DMAC0180C2000022RemoteAread-writecurrentNID Series card Port 3 L2CP Mode 0180C2000022 0: Forward 1: Discard 2: Peer
1.3.6.1.4.1.4756.20.501.20.1.1750ColumnnidL2CPPort3DMAC0180C2000023RemoteAread-writecurrentNID Series card Port 3 L2CP Mode 0180C2000023 0: Forward 1: Discard 2: Peer
1.3.6.1.4.1.4756.20.501.20.1.1751ColumnnidL2CPPort3DMAC0180C2000024RemoteAread-writecurrentNID Series card Port 3 L2CP Mode 0180C2000024 0: Forward 1: Discard 2: Peer
1.3.6.1.4.1.4756.20.501.20.1.1752ColumnnidL2CPPort3DMAC0180C2000025RemoteAread-writecurrentNID Series card Port 3 L2CP Mode 0180C2000025 0: Forward 1: Discard 2: Peer
1.3.6.1.4.1.4756.20.501.20.1.1753ColumnnidL2CPPort3DMAC0180C2000026RemoteAread-writecurrentNID Series card Port 3 L2CP Mode 0180C2000026 0: Forward 1: Discard 2: Peer
1.3.6.1.4.1.4756.20.501.20.1.1754ColumnnidL2CPPort3DMAC0180C2000027RemoteAread-writecurrentNID Series card Port 3 L2CP Mode 0180C2000027 0: Forward 1: Discard 2: Peer
1.3.6.1.4.1.4756.20.501.20.1.1755ColumnnidL2CPPort3DMAC0180C2000028RemoteAread-writecurrentNID Series card Port 3 L2CP Mode 0180C2000028 0: Forward 1: Discard 2: Peer
1.3.6.1.4.1.4756.20.501.20.1.1756ColumnnidL2CPPort3DMAC0180C2000029RemoteAread-writecurrentNID Series card Port 3 L2CP Mode 0180C2000029 0: Forward 1: Discard 2: Peer
1.3.6.1.4.1.4756.20.501.20.1.1757ColumnnidL2CPPort3DMAC0180C200002ARemoteAread-writecurrentNID Series card Port 3 L2CP Mode 0180C200002A 0: Forward 1: Discard 2: Peer
1.3.6.1.4.1.4756.20.501.20.1.1758ColumnnidL2CPPort3DMAC0180C200002BRemoteAread-writecurrentNID Series card Port 3 L2CP Mode 0180C200002B 0: Forward 1: Discard 2: Peer
1.3.6.1.4.1.4756.20.501.20.1.1759ColumnnidL2CPPort3DMAC0180C200002CRemoteAread-writecurrentNID Series card Port 3 L2CP Mode 0180C200002C 0: Forward 1: Discard 2: Peer
1.3.6.1.4.1.4756.20.501.20.1.1760ColumnnidL2CPPort3DMAC0180C200002DRemoteAread-writecurrentNID Series card Port 3 L2CP Mode 0180C200002D 0: Forward 1: Discard 2: Peer
1.3.6.1.4.1.4756.20.501.20.1.1761ColumnnidL2CPPort3DMAC0180C200002ERemoteAread-writecurrentNID Series card Port 3 L2CP Mode 0180C200002E 0: Forward 1: Discard 2: Peer
1.3.6.1.4.1.4756.20.501.20.1.1762ColumnnidL2CPPort3DMAC0180C200002FRemoteAread-writecurrentNID Series card Port 3 L2CP Mode 0180C200002F 0: Forward 1: Discard 1: Peer
1.3.6.1.4.1.4756.20.501.20.1.1763ColumnnidL2CPPort4DMAC0180C2000000RemoteAread-writecurrentNID Series card Port 4 L2CP Mode 0180C2000000 0: Forward 1: Discard 2: Peer
1.3.6.1.4.1.4756.20.501.20.1.1764ColumnnidL2CPPort4DMAC0180C2000001RemoteAread-writecurrentNID Series card Port 4 L2CP Mode 0180C2000001 0: Forward 1: Discard 2: Peer
1.3.6.1.4.1.4756.20.501.20.1.1765ColumnnidL2CPPort4DMAC0180C2000002RemoteAread-writecurrentNID Series card Port 4 L2CP Mode 0180C2000002 0: Forward 1: Discard 2: Peer
1.3.6.1.4.1.4756.20.501.20.1.1766ColumnnidL2CPPort4DMAC0180C2000003RemoteAread-writecurrentNID Series card Port 4 L2CP Mode 0180C2000003 0: Forward 1: Discard 2: Peer
1.3.6.1.4.1.4756.20.501.20.1.1767ColumnnidL2CPPort4DMAC0180C2000004RemoteAread-writecurrentNID Series card Port 4 L2CP Mode 0180C2000004 0: Forward 1: Discard 2: Peer
1.3.6.1.4.1.4756.20.501.20.1.1768ColumnnidL2CPPort4DMAC0180C2000005RemoteAread-writecurrentNID Series card Port 4 L2CP Mode 0180C2000005 0: Forward 1: Discard 2: Peer
1.3.6.1.4.1.4756.20.501.20.1.1769ColumnnidL2CPPort4DMAC0180C2000006RemoteAread-writecurrentNID Series card Port 4 L2CP Mode 0180C2000006 0: Forward 1: Discard 2: Peer
1.3.6.1.4.1.4756.20.501.20.1.1770ColumnnidL2CPPort4DMAC0180C2000007RemoteAread-writecurrentNID Series card Port 4 L2CP Mode 0180C2000007 0: Forward 1: Discard 2: Peer
1.3.6.1.4.1.4756.20.501.20.1.1771ColumnnidL2CPPort4DMAC0180C2000008RemoteAread-writecurrentNID Series card Port 4 L2CP Mode 0180C2000008 0: Forward 1: Discard 2: Peer
1.3.6.1.4.1.4756.20.501.20.1.1772ColumnnidL2CPPort4DMAC0180C2000009RemoteAread-writecurrentNID Series card Port 4 L2CP Mode 0180C2000009 0: Forward 1: Discard 2: Peer
1.3.6.1.4.1.4756.20.501.20.1.1773ColumnnidL2CPPort4DMAC0180C200000ARemoteAread-writecurrentNID Series card Port 4 L2CP Mode 0180C200000A 0: Forward 1: Discard 2: Peer
1.3.6.1.4.1.4756.20.501.20.1.1774ColumnnidL2CPPort4DMAC0180C200000BRemoteAread-writecurrentNID Series card Port 4 L2CP Mode 0180C200000B 0: Forward 1: Discard 2: Peer
1.3.6.1.4.1.4756.20.501.20.1.1775ColumnnidL2CPPort4DMAC0180C200000CRemoteAread-writecurrentNID Series card Port 4 L2CP Mode 0180C200000C 0: Forward 1: Discard 2: Peer
1.3.6.1.4.1.4756.20.501.20.1.1776ColumnnidL2CPPort4DMAC0180C200000DRemoteAread-writecurrentNID Series card Port 4 L2CP Mode 0180C200000D 0: Forward 1: Discard 2: Peer
1.3.6.1.4.1.4756.20.501.20.1.1777ColumnnidL2CPPort4DMAC0180C200000ERemoteAread-writecurrentNID Series card Port 4 L2CP Mode 0180C200000E 0: Forward 1: Discard 2: Peer
1.3.6.1.4.1.4756.20.501.20.1.1778ColumnnidL2CPPort4DMAC0180C200000FRemoteAread-writecurrentNID Series card Port 4 L2CP Mode 0180C200000F 0: Forward 1: Discard 2: Peer
1.3.6.1.4.1.4756.20.501.20.1.1779ColumnnidL2CPPort4DMAC0180C2000010RemoteAread-writecurrentNID Series card Port 4 L2CP Mode 0180C2000010 0: Forward 1: Discard 2: Peer
1.3.6.1.4.1.4756.20.501.20.1.1780ColumnnidL2CPPort4DMAC0180C2000020RemoteAread-writecurrentNID Series card Port 4 L2CP Mode 0180C2000020 0: Forward 1: Discard 2: Peer
1.3.6.1.4.1.4756.20.501.20.1.1781ColumnnidL2CPPort4DMAC0180C2000021RemoteAread-writecurrentNID Series card Port 4 L2CP Mode 0180C2000021 0: Forward 1: Discard 2: Peer
1.3.6.1.4.1.4756.20.501.20.1.1782ColumnnidL2CPPort4DMAC0180C2000022RemoteAread-writecurrentNID Series card Port 4 L2CP Mode 0180C2000022 0: Forward 1: Discard 2: Peer
1.3.6.1.4.1.4756.20.501.20.1.1783ColumnnidL2CPPort4DMAC0180C2000023RemoteAread-writecurrentNID Series card Port 4 L2CP Mode 0180C2000023 0: Forward 1: Discard 2: Peer
1.3.6.1.4.1.4756.20.501.20.1.1784ColumnnidL2CPPort4DMAC0180C2000024RemoteAread-writecurrentNID Series card Port 4 L2CP Mode 0180C2000024 0: Forward 1: Discard 2: Peer
1.3.6.1.4.1.4756.20.501.20.1.1785ColumnnidL2CPPort4DMAC0180C2000025RemoteAread-writecurrentNID Series card Port 4 L2CP Mode 0180C2000025 0: Forward 1: Discard 2: Peer
1.3.6.1.4.1.4756.20.501.20.1.1786ColumnnidL2CPPort4DMAC0180C2000026RemoteAread-writecurrentNID Series card Port 4 L2CP Mode 0180C2000026 0: Forward 1: Discard 2: Peer
1.3.6.1.4.1.4756.20.501.20.1.1787ColumnnidL2CPPort4DMAC0180C2000027RemoteAread-writecurrentNID Series card Port 4 L2CP Mode 0180C2000027 0: Forward 1: Discard 2: Peer
1.3.6.1.4.1.4756.20.501.20.1.1788ColumnnidL2CPPort4DMAC0180C2000028RemoteAread-writecurrentNID Series card Port 4 L2CP Mode 0180C2000028 0: Forward 1: Discard 2: Peer
1.3.6.1.4.1.4756.20.501.20.1.1789ColumnnidL2CPPort4DMAC0180C2000029RemoteAread-writecurrentNID Series card Port 4 L2CP Mode 0180C2000029 0: Forward 1: Discard 2: Peer
1.3.6.1.4.1.4756.20.501.20.1.1790ColumnnidL2CPPort4DMAC0180C200002ARemoteAread-writecurrentNID Series card Port 4 L2CP Mode 0180C200002A 0: Forward 1: Discard 2: Peer
1.3.6.1.4.1.4756.20.501.20.1.1791ColumnnidL2CPPort4DMAC0180C200002BRemoteAread-writecurrentNID Series card Port 4 L2CP Mode 0180C200002B 0: Forward 1: Discard 2: Peer
1.3.6.1.4.1.4756.20.501.20.1.1792ColumnnidL2CPPort4DMAC0180C200002CRemoteAread-writecurrentNID Series card Port 4 L2CP Mode 0180C200002C 0: Forward 1: Discard 2: Peer
1.3.6.1.4.1.4756.20.501.20.1.1793ColumnnidL2CPPort4DMAC0180C200002DRemoteAread-writecurrentNID Series card Port 4 L2CP Mode 0180C200002D 0: Forward 1: Discard 2: Peer
1.3.6.1.4.1.4756.20.501.20.1.1794ColumnnidL2CPPort4DMAC0180C200002ERemoteAread-writecurrentNID Series card Port 4 L2CP Mode 0180C200002E 0: Forward 1: Discard 2: Peer
1.3.6.1.4.1.4756.20.501.20.1.1795ColumnnidL2CPPort4DMAC0180C200002FRemoteAread-writecurrentNID Series card Port 4 L2CP Mode 0180C200002F 0: Forward 1: Discard 1: Peer
1.3.6.1.4.1.4756.20.501.20.1.1796ColumnnidL2CPPort5DMAC0180C2000000RemoteAread-writecurrentNID Series card Port 5 L2CP Mode 0180C2000000 0: Forward 1: Discard 2: Peer
1.3.6.1.4.1.4756.20.501.20.1.1797ColumnnidL2CPPort5DMAC0180C2000001RemoteAread-writecurrentNID Series card Port 5 L2CP Mode 0180C2000001 0: Forward 1: Discard 2: Peer
1.3.6.1.4.1.4756.20.501.20.1.1798ColumnnidL2CPPort5DMAC0180C2000002RemoteAread-writecurrentNID Series card Port 5 L2CP Mode 0180C2000002 0: Forward 1: Discard 2: Peer
1.3.6.1.4.1.4756.20.501.20.1.1799ColumnnidL2CPPort5DMAC0180C2000003RemoteAread-writecurrentNID Series card Port 5 L2CP Mode 0180C2000003 0: Forward 1: Discard 2: Peer
1.3.6.1.4.1.4756.20.501.20.1.1800ColumnnidL2CPPort5DMAC0180C2000004RemoteAread-writecurrentNID Series card Port 5 L2CP Mode 0180C2000004 0: Forward 1: Discard 2: Peer
1.3.6.1.4.1.4756.20.501.20.1.1801ColumnnidL2CPPort5DMAC0180C2000005RemoteAread-writecurrentNID Series card Port 5 L2CP Mode 0180C2000005 0: Forward 1: Discard 2: Peer
1.3.6.1.4.1.4756.20.501.20.1.1802ColumnnidL2CPPort5DMAC0180C2000006RemoteAread-writecurrentNID Series card Port 5 L2CP Mode 0180C2000006 0: Forward 1: Discard 2: Peer
1.3.6.1.4.1.4756.20.501.20.1.1803ColumnnidL2CPPort5DMAC0180C2000007RemoteAread-writecurrentNID Series card Port 5 L2CP Mode 0180C2000007 0: Forward 1: Discard 2: Peer
1.3.6.1.4.1.4756.20.501.20.1.1804ColumnnidL2CPPort5DMAC0180C2000008RemoteAread-writecurrentNID Series card Port 5 L2CP Mode 0180C2000008 0: Forward 1: Discard 2: Peer
1.3.6.1.4.1.4756.20.501.20.1.1805ColumnnidL2CPPort5DMAC0180C2000009RemoteAread-writecurrentNID Series card Port 5 L2CP Mode 0180C2000009 0: Forward 1: Discard 2: Peer
1.3.6.1.4.1.4756.20.501.20.1.1806ColumnnidL2CPPort5DMAC0180C200000ARemoteAread-writecurrentNID Series card Port 5 L2CP Mode 0180C200000A 0: Forward 1: Discard 2: Peer
1.3.6.1.4.1.4756.20.501.20.1.1807ColumnnidL2CPPort5DMAC0180C200000BRemoteAread-writecurrentNID Series card Port 5 L2CP Mode 0180C200000B 0: Forward 1: Discard 2: Peer
1.3.6.1.4.1.4756.20.501.20.1.1808ColumnnidL2CPPort5DMAC0180C200000CRemoteAread-writecurrentNID Series card Port 5 L2CP Mode 0180C200000C 0: Forward 1: Discard 2: Peer
1.3.6.1.4.1.4756.20.501.20.1.1809ColumnnidL2CPPort5DMAC0180C200000DRemoteAread-writecurrentNID Series card Port 5 L2CP Mode 0180C200000D 0: Forward 1: Discard 2: Peer
1.3.6.1.4.1.4756.20.501.20.1.1810ColumnnidL2CPPort5DMAC0180C200000ERemoteAread-writecurrentNID Series card Port 5 L2CP Mode 0180C200000E 0: Forward 1: Discard 2: Peer
1.3.6.1.4.1.4756.20.501.20.1.1811ColumnnidL2CPPort5DMAC0180C200000FRemoteAread-writecurrentNID Series card Port 5 L2CP Mode 0180C200000F 0: Forward 1: Discard 2: Peer
1.3.6.1.4.1.4756.20.501.20.1.1812ColumnnidL2CPPort5DMAC0180C2000010RemoteAread-writecurrentNID Series card Port 5 L2CP Mode 0180C2000010 0: Forward 1: Discard 2: Peer
1.3.6.1.4.1.4756.20.501.20.1.1813ColumnnidL2CPPort5DMAC0180C2000020RemoteAread-writecurrentNID Series card Port 5 L2CP Mode 0180C2000020 0: Forward 1: Discard 2: Peer
1.3.6.1.4.1.4756.20.501.20.1.1814ColumnnidL2CPPort5DMAC0180C2000021RemoteAread-writecurrentNID Series card Port 5 L2CP Mode 0180C2000021 0: Forward 1: Discard 2: Peer
1.3.6.1.4.1.4756.20.501.20.1.1815ColumnnidL2CPPort5DMAC0180C2000022RemoteAread-writecurrentNID Series card Port 5 L2CP Mode 0180C2000022 0: Forward 1: Discard 2: Peer
1.3.6.1.4.1.4756.20.501.20.1.1816ColumnnidL2CPPort5DMAC0180C2000023RemoteAread-writecurrentNID Series card Port 5 L2CP Mode 0180C2000023 0: Forward 1: Discard 2: Peer
1.3.6.1.4.1.4756.20.501.20.1.1817ColumnnidL2CPPort5DMAC0180C2000024RemoteAread-writecurrentNID Series card Port 5 L2CP Mode 0180C2000024 0: Forward 1: Discard 2: Peer
1.3.6.1.4.1.4756.20.501.20.1.1818ColumnnidL2CPPort5DMAC0180C2000025RemoteAread-writecurrentNID Series card Port 5 L2CP Mode 0180C2000025 0: Forward 1: Discard 2: Peer
1.3.6.1.4.1.4756.20.501.20.1.1819ColumnnidL2CPPort5DMAC0180C2000026RemoteAread-writecurrentNID Series card Port 5 L2CP Mode 0180C2000026 0: Forward 1: Discard 2: Peer
1.3.6.1.4.1.4756.20.501.20.1.1820ColumnnidL2CPPort5DMAC0180C2000027RemoteAread-writecurrentNID Series card Port 5 L2CP Mode 0180C2000027 0: Forward 1: Discard 2: Peer
1.3.6.1.4.1.4756.20.501.20.1.1821ColumnnidL2CPPort5DMAC0180C2000028RemoteAread-writecurrentNID Series card Port 5 L2CP Mode 0180C2000028 0: Forward 1: Discard 2: Peer
1.3.6.1.4.1.4756.20.501.20.1.1822ColumnnidL2CPPort5DMAC0180C2000029RemoteAread-writecurrentNID Series card Port 5 L2CP Mode 0180C2000029 0: Forward 1: Discard 2: Peer
1.3.6.1.4.1.4756.20.501.20.1.1823ColumnnidL2CPPort5DMAC0180C200002ARemoteAread-writecurrentNID Series card Port 5 L2CP Mode 0180C200002A 0: Forward 1: Discard 2: Peer
1.3.6.1.4.1.4756.20.501.20.1.1824ColumnnidL2CPPort5DMAC0180C200002BRemoteAread-writecurrentNID Series card Port 5 L2CP Mode 0180C200002B 0: Forward 1: Discard 2: Peer
1.3.6.1.4.1.4756.20.501.20.1.1825ColumnnidL2CPPort5DMAC0180C200002CRemoteAread-writecurrentNID Series card Port 5 L2CP Mode 0180C200002C 0: Forward 1: Discard 2: Peer
1.3.6.1.4.1.4756.20.501.20.1.1826ColumnnidL2CPPort5DMAC0180C200002DRemoteAread-writecurrentNID Series card Port 5 L2CP Mode 0180C200002D 0: Forward 1: Discard 2: Peer
1.3.6.1.4.1.4756.20.501.20.1.1827ColumnnidL2CPPort5DMAC0180C200002ERemoteAread-writecurrentNID Series card Port 5 L2CP Mode 0180C200002E 0: Forward 1: Discard 2: Peer
1.3.6.1.4.1.4756.20.501.20.1.1828ColumnnidL2CPPort5DMAC0180C200002FRemoteAread-writecurrentNID Series card Port 5 L2CP Mode 0180C200002F 0: Forward 1: Discard 1: Peer
1.3.6.1.4.1.4756.20.501.20.1.1829ColumnnidL2CPPort6DMAC0180C2000000RemoteAread-writecurrentNID Series card Port 6 L2CP Mode 0180C2000000 0: Forward 1: Discard 2: Peer
1.3.6.1.4.1.4756.20.501.20.1.1830ColumnnidL2CPPort6DMAC0180C2000001RemoteAread-writecurrentNID Series card Port 6 L2CP Mode 0180C2000001 0: Forward 1: Discard 2: Peer
1.3.6.1.4.1.4756.20.501.20.1.1831ColumnnidL2CPPort6DMAC0180C2000002RemoteAread-writecurrentNID Series card Port 6 L2CP Mode 0180C2000002 0: Forward 1: Discard 2: Peer
1.3.6.1.4.1.4756.20.501.20.1.1832ColumnnidL2CPPort6DMAC0180C2000003RemoteAread-writecurrentNID Series card Port 6 L2CP Mode 0180C2000003 0: Forward 1: Discard 2: Peer
1.3.6.1.4.1.4756.20.501.20.1.1833ColumnnidL2CPPort6DMAC0180C2000004RemoteAread-writecurrentNID Series card Port 6 L2CP Mode 0180C2000004 0: Forward 1: Discard 2: Peer
1.3.6.1.4.1.4756.20.501.20.1.1834ColumnnidL2CPPort6DMAC0180C2000005RemoteAread-writecurrentNID Series card Port 6 L2CP Mode 0180C2000005 0: Forward 1: Discard 2: Peer
1.3.6.1.4.1.4756.20.501.20.1.1835ColumnnidL2CPPort6DMAC0180C2000006RemoteAread-writecurrentNID Series card Port 6 L2CP Mode 0180C2000006 0: Forward 1: Discard 2: Peer
1.3.6.1.4.1.4756.20.501.20.1.1836ColumnnidL2CPPort6DMAC0180C2000007RemoteAread-writecurrentNID Series card Port 6 L2CP Mode 0180C2000007 0: Forward 1: Discard 2: Peer
1.3.6.1.4.1.4756.20.501.20.1.1837ColumnnidL2CPPort6DMAC0180C2000008RemoteAread-writecurrentNID Series card Port 6 L2CP Mode 0180C2000008 0: Forward 1: Discard 2: Peer
1.3.6.1.4.1.4756.20.501.20.1.1838ColumnnidL2CPPort6DMAC0180C2000009RemoteAread-writecurrentNID Series card Port 6 L2CP Mode 0180C2000009 0: Forward 1: Discard 2: Peer
1.3.6.1.4.1.4756.20.501.20.1.1839ColumnnidL2CPPort6DMAC0180C200000ARemoteAread-writecurrentNID Series card Port 6 L2CP Mode 0180C200000A 0: Forward 1: Discard 2: Peer
1.3.6.1.4.1.4756.20.501.20.1.1840ColumnnidL2CPPort6DMAC0180C200000BRemoteAread-writecurrentNID Series card Port 6 L2CP Mode 0180C200000B 0: Forward 1: Discard 2: Peer
1.3.6.1.4.1.4756.20.501.20.1.1841ColumnnidL2CPPort6DMAC0180C200000CRemoteAread-writecurrentNID Series card Port 6 L2CP Mode 0180C200000C 0: Forward 1: Discard 2: Peer
1.3.6.1.4.1.4756.20.501.20.1.1842ColumnnidL2CPPort6DMAC0180C200000DRemoteAread-writecurrentNID Series card Port 6 L2CP Mode 0180C200000D 0: Forward 1: Discard 2: Peer
1.3.6.1.4.1.4756.20.501.20.1.1843ColumnnidL2CPPort6DMAC0180C200000ERemoteAread-writecurrentNID Series card Port 6 L2CP Mode 0180C200000E 0: Forward 1: Discard 2: Peer
1.3.6.1.4.1.4756.20.501.20.1.1844ColumnnidL2CPPort6DMAC0180C200000FRemoteAread-writecurrentNID Series card Port 6 L2CP Mode 0180C200000F 0: Forward 1: Discard 2: Peer
1.3.6.1.4.1.4756.20.501.20.1.1845ColumnnidL2CPPort6DMAC0180C2000010RemoteAread-writecurrentNID Series card Port 6 L2CP Mode 0180C2000010 0: Forward 1: Discard 2: Peer
1.3.6.1.4.1.4756.20.501.20.1.1846ColumnnidL2CPPort6DMAC0180C2000020RemoteAread-writecurrentNID Series card Port 6 L2CP Mode 0180C2000020 0: Forward 1: Discard 2: Peer
1.3.6.1.4.1.4756.20.501.20.1.1847ColumnnidL2CPPort6DMAC0180C2000021RemoteAread-writecurrentNID Series card Port 6 L2CP Mode 0180C2000021 0: Forward 1: Discard 2: Peer
1.3.6.1.4.1.4756.20.501.20.1.1848ColumnnidL2CPPort6DMAC0180C2000022RemoteAread-writecurrentNID Series card Port 6 L2CP Mode 0180C2000022 0: Forward 1: Discard 2: Peer
1.3.6.1.4.1.4756.20.501.20.1.1849ColumnnidL2CPPort6DMAC0180C2000023RemoteAread-writecurrentNID Series card Port 6 L2CP Mode 0180C2000023 0: Forward 1: Discard 2: Peer
1.3.6.1.4.1.4756.20.501.20.1.1850ColumnnidL2CPPort6DMAC0180C2000024RemoteAread-writecurrentNID Series card Port 6 L2CP Mode 0180C2000024 0: Forward 1: Discard 2: Peer
1.3.6.1.4.1.4756.20.501.20.1.1851ColumnnidL2CPPort6DMAC0180C2000025RemoteAread-writecurrentNID Series card Port 6 L2CP Mode 0180C2000025 0: Forward 1: Discard 2: Peer
1.3.6.1.4.1.4756.20.501.20.1.1852ColumnnidL2CPPort6DMAC0180C2000026RemoteAread-writecurrentNID Series card Port 6 L2CP Mode 0180C2000026 0: Forward 1: Discard 2: Peer
1.3.6.1.4.1.4756.20.501.20.1.1853ColumnnidL2CPPort6DMAC0180C2000027RemoteAread-writecurrentNID Series card Port 6 L2CP Mode 0180C2000027 0: Forward 1: Discard 2: Peer
1.3.6.1.4.1.4756.20.501.20.1.1854ColumnnidL2CPPort6DMAC0180C2000028RemoteAread-writecurrentNID Series card Port 6 L2CP Mode 0180C2000028 0: Forward 1: Discard 2: Peer
1.3.6.1.4.1.4756.20.501.20.1.1855ColumnnidL2CPPort6DMAC0180C2000029RemoteAread-writecurrentNID Series card Port 6 L2CP Mode 0180C2000029 0: Forward 1: Discard 2: Peer
1.3.6.1.4.1.4756.20.501.20.1.1856ColumnnidL2CPPort6DMAC0180C200002ARemoteAread-writecurrentNID Series card Port 6 L2CP Mode 0180C200002A 0: Forward 1: Discard 2: Peer
1.3.6.1.4.1.4756.20.501.20.1.1857ColumnnidL2CPPort6DMAC0180C200002BRemoteAread-writecurrentNID Series card Port 6 L2CP Mode 0180C200002B 0: Forward 1: Discard 2: Peer
1.3.6.1.4.1.4756.20.501.20.1.1858ColumnnidL2CPPort6DMAC0180C200002CRemoteAread-writecurrentNID Series card Port 6 L2CP Mode 0180C200002C 0: Forward 1: Discard 2: Peer
1.3.6.1.4.1.4756.20.501.20.1.1859ColumnnidL2CPPort6DMAC0180C200002DRemoteAread-writecurrentNID Series card Port 6 L2CP Mode 0180C200002D 0: Forward 1: Discard 2: Peer
1.3.6.1.4.1.4756.20.501.20.1.1860ColumnnidL2CPPort6DMAC0180C200002ERemoteAread-writecurrentNID Series card Port 6 L2CP Mode 0180C200002E 0: Forward 1: Discard 2: Peer
1.3.6.1.4.1.4756.20.501.20.1.1861ColumnnidL2CPPort6DMAC0180C200002FRemoteAread-writecurrentNID Series card Port 6 L2CP Mode 0180C200002F 0: Forward 1: Discard 1: Peer
1.3.6.1.4.1.4756.20.501.20.1.1862ColumnnidL2CPPort7DMAC0180C2000000RemoteAread-writecurrentNID Series card Port 7 L2CP Mode 0180C2000000 0: Forward 1: Discard 2: Peer
1.3.6.1.4.1.4756.20.501.20.1.1863ColumnnidL2CPPort7DMAC0180C2000001RemoteAread-writecurrentNID Series card Port 7 L2CP Mode 0180C2000001 0: Forward 1: Discard 2: Peer
1.3.6.1.4.1.4756.20.501.20.1.1864ColumnnidL2CPPort7DMAC0180C2000002RemoteAread-writecurrentNID Series card Port 7 L2CP Mode 0180C2000002 0: Forward 1: Discard 2: Peer
1.3.6.1.4.1.4756.20.501.20.1.1865ColumnnidL2CPPort7DMAC0180C2000003RemoteAread-writecurrentNID Series card Port 7 L2CP Mode 0180C2000003 0: Forward 1: Discard 2: Peer
1.3.6.1.4.1.4756.20.501.20.1.1866ColumnnidL2CPPort7DMAC0180C2000004RemoteAread-writecurrentNID Series card Port 7 L2CP Mode 0180C2000004 0: Forward 1: Discard 2: Peer
1.3.6.1.4.1.4756.20.501.20.1.1867ColumnnidL2CPPort7DMAC0180C2000005RemoteAread-writecurrentNID Series card Port 7 L2CP Mode 0180C2000005 0: Forward 1: Discard 2: Peer
1.3.6.1.4.1.4756.20.501.20.1.1868ColumnnidL2CPPort7DMAC0180C2000006RemoteAread-writecurrentNID Series card Port 7 L2CP Mode 0180C2000006 0: Forward 1: Discard 2: Peer
1.3.6.1.4.1.4756.20.501.20.1.1869ColumnnidL2CPPort7DMAC0180C2000007RemoteAread-writecurrentNID Series card Port 7 L2CP Mode 0180C2000007 0: Forward 1: Discard 2: Peer
1.3.6.1.4.1.4756.20.501.20.1.1870ColumnnidL2CPPort7DMAC0180C2000008RemoteAread-writecurrentNID Series card Port 7 L2CP Mode 0180C2000008 0: Forward 1: Discard 2: Peer
1.3.6.1.4.1.4756.20.501.20.1.1871ColumnnidL2CPPort7DMAC0180C2000009RemoteAread-writecurrentNID Series card Port 7 L2CP Mode 0180C2000009 0: Forward 1: Discard 2: Peer
1.3.6.1.4.1.4756.20.501.20.1.1872ColumnnidL2CPPort7DMAC0180C200000ARemoteAread-writecurrentNID Series card Port 7 L2CP Mode 0180C200000A 0: Forward 1: Discard 2: Peer
1.3.6.1.4.1.4756.20.501.20.1.1873ColumnnidL2CPPort7DMAC0180C200000BRemoteAread-writecurrentNID Series card Port 7 L2CP Mode 0180C200000B 0: Forward 1: Discard 2: Peer
1.3.6.1.4.1.4756.20.501.20.1.1874ColumnnidL2CPPort7DMAC0180C200000CRemoteAread-writecurrentNID Series card Port 7 L2CP Mode 0180C200000C 0: Forward 1: Discard 2: Peer
1.3.6.1.4.1.4756.20.501.20.1.1875ColumnnidL2CPPort7DMAC0180C200000DRemoteAread-writecurrentNID Series card Port 7 L2CP Mode 0180C200000D 0: Forward 1: Discard 2: Peer
1.3.6.1.4.1.4756.20.501.20.1.1876ColumnnidL2CPPort7DMAC0180C200000ERemoteAread-writecurrentNID Series card Port 7 L2CP Mode 0180C200000E 0: Forward 1: Discard 2: Peer
1.3.6.1.4.1.4756.20.501.20.1.1877ColumnnidL2CPPort7DMAC0180C200000FRemoteAread-writecurrentNID Series card Port 7 L2CP Mode 0180C200000F 0: Forward 1: Discard 2: Peer
1.3.6.1.4.1.4756.20.501.20.1.1878ColumnnidL2CPPort7DMAC0180C2000010RemoteAread-writecurrentNID Series card Port 7 L2CP Mode 0180C2000010 0: Forward 1: Discard 2: Peer
1.3.6.1.4.1.4756.20.501.20.1.1879ColumnnidL2CPPort7DMAC0180C2000020RemoteAread-writecurrentNID Series card Port 7 L2CP Mode 0180C2000020 0: Forward 1: Discard 2: Peer
1.3.6.1.4.1.4756.20.501.20.1.1880ColumnnidL2CPPort7DMAC0180C2000021RemoteAread-writecurrentNID Series card Port 7 L2CP Mode 0180C2000021 0: Forward 1: Discard 2: Peer
1.3.6.1.4.1.4756.20.501.20.1.1881ColumnnidL2CPPort7DMAC0180C2000022RemoteAread-writecurrentNID Series card Port 7 L2CP Mode 0180C2000022 0: Forward 1: Discard 2: Peer
1.3.6.1.4.1.4756.20.501.20.1.1882ColumnnidL2CPPort7DMAC0180C2000023RemoteAread-writecurrentNID Series card Port 7 L2CP Mode 0180C2000023 0: Forward 1: Discard 2: Peer
1.3.6.1.4.1.4756.20.501.20.1.1883ColumnnidL2CPPort7DMAC0180C2000024RemoteAread-writecurrentNID Series card Port 7 L2CP Mode 0180C2000024 0: Forward 1: Discard 2: Peer
1.3.6.1.4.1.4756.20.501.20.1.1884ColumnnidL2CPPort7DMAC0180C2000025RemoteAread-writecurrentNID Series card Port 7 L2CP Mode 0180C2000025 0: Forward 1: Discard 2: Peer
1.3.6.1.4.1.4756.20.501.20.1.1885ColumnnidL2CPPort7DMAC0180C2000026RemoteAread-writecurrentNID Series card Port 7 L2CP Mode 0180C2000026 0: Forward 1: Discard 2: Peer
1.3.6.1.4.1.4756.20.501.20.1.1886ColumnnidL2CPPort7DMAC0180C2000027RemoteAread-writecurrentNID Series card Port 7 L2CP Mode 0180C2000027 0: Forward 1: Discard 2: Peer
1.3.6.1.4.1.4756.20.501.20.1.1887ColumnnidL2CPPort7DMAC0180C2000028RemoteAread-writecurrentNID Series card Port 7 L2CP Mode 0180C2000028 0: Forward 1: Discard 2: Peer
1.3.6.1.4.1.4756.20.501.20.1.1888ColumnnidL2CPPort7DMAC0180C2000029RemoteAread-writecurrentNID Series card Port 7 L2CP Mode 0180C2000029 0: Forward 1: Discard 2: Peer
1.3.6.1.4.1.4756.20.501.20.1.1889ColumnnidL2CPPort7DMAC0180C200002ARemoteAread-writecurrentNID Series card Port 7 L2CP Mode 0180C200002A 0: Forward 1: Discard 2: Peer
1.3.6.1.4.1.4756.20.501.20.1.1890ColumnnidL2CPPort7DMAC0180C200002BRemoteAread-writecurrentNID Series card Port 7 L2CP Mode 0180C200002B 0: Forward 1: Discard 2: Peer
1.3.6.1.4.1.4756.20.501.20.1.1891ColumnnidL2CPPort7DMAC0180C200002CRemoteAread-writecurrentNID Series card Port 7 L2CP Mode 0180C200002C 0: Forward 1: Discard 2: Peer
1.3.6.1.4.1.4756.20.501.20.1.1892ColumnnidL2CPPort7DMAC0180C200002DRemoteAread-writecurrentNID Series card Port 7 L2CP Mode 0180C200002D 0: Forward 1: Discard 2: Peer
1.3.6.1.4.1.4756.20.501.20.1.1893ColumnnidL2CPPort7DMAC0180C200002ERemoteAread-writecurrentNID Series card Port 7 L2CP Mode 0180C200002E 0: Forward 1: Discard 2: Peer
1.3.6.1.4.1.4756.20.501.20.1.1894ColumnnidL2CPPort7DMAC0180C200002FRemoteAread-writecurrentNID Series card Port 7 L2CP Mode 0180C200002F 0: Forward 1: Discard 1: Peer
1.3.6.1.4.1.4756.20.501.20.1.1895ColumnnidL2CPPort8DMAC0180C2000000RemoteAread-writecurrentNID Series card Port 8 L2CP Mode 0180C2000000 0: Forward 1: Discard 2: Peer
1.3.6.1.4.1.4756.20.501.20.1.1896ColumnnidL2CPPort8DMAC0180C2000001RemoteAread-writecurrentNID Series card Port 8 L2CP Mode 0180C2000001 0: Forward 1: Discard 2: Peer
1.3.6.1.4.1.4756.20.501.20.1.1897ColumnnidL2CPPort8DMAC0180C2000002RemoteAread-writecurrentNID Series card Port 8 L2CP Mode 0180C2000002 0: Forward 1: Discard 2: Peer
1.3.6.1.4.1.4756.20.501.20.1.1898ColumnnidL2CPPort8DMAC0180C2000003RemoteAread-writecurrentNID Series card Port 8 L2CP Mode 0180C2000003 0: Forward 1: Discard 2: Peer
1.3.6.1.4.1.4756.20.501.20.1.1899ColumnnidL2CPPort8DMAC0180C2000004RemoteAread-writecurrentNID Series card Port 8 L2CP Mode 0180C2000004 0: Forward 1: Discard 2: Peer
1.3.6.1.4.1.4756.20.501.20.1.1900ColumnnidL2CPPort8DMAC0180C2000005RemoteAread-writecurrentNID Series card Port 8 L2CP Mode 0180C2000005 0: Forward 1: Discard 2: Peer
1.3.6.1.4.1.4756.20.501.20.1.1901ColumnnidL2CPPort8DMAC0180C2000006RemoteAread-writecurrentNID Series card Port 8 L2CP Mode 0180C2000006 0: Forward 1: Discard 2: Peer
1.3.6.1.4.1.4756.20.501.20.1.1902ColumnnidL2CPPort8DMAC0180C2000007RemoteAread-writecurrentNID Series card Port 8 L2CP Mode 0180C2000007 0: Forward 1: Discard 2: Peer
1.3.6.1.4.1.4756.20.501.20.1.1903ColumnnidL2CPPort8DMAC0180C2000008RemoteAread-writecurrentNID Series card Port 8 L2CP Mode 0180C2000008 0: Forward 1: Discard 2: Peer
1.3.6.1.4.1.4756.20.501.20.1.1904ColumnnidL2CPPort8DMAC0180C2000009RemoteAread-writecurrentNID Series card Port 8 L2CP Mode 0180C2000009 0: Forward 1: Discard 2: Peer
1.3.6.1.4.1.4756.20.501.20.1.1905ColumnnidL2CPPort8DMAC0180C200000ARemoteAread-writecurrentNID Series card Port 8 L2CP Mode 0180C200000A 0: Forward 1: Discard 2: Peer
1.3.6.1.4.1.4756.20.501.20.1.1906ColumnnidL2CPPort8DMAC0180C200000BRemoteAread-writecurrentNID Series card Port 8 L2CP Mode 0180C200000B 0: Forward 1: Discard 2: Peer
1.3.6.1.4.1.4756.20.501.20.1.1907ColumnnidL2CPPort8DMAC0180C200000CRemoteAread-writecurrentNID Series card Port 8 L2CP Mode 0180C200000C 0: Forward 1: Discard 2: Peer
1.3.6.1.4.1.4756.20.501.20.1.1908ColumnnidL2CPPort8DMAC0180C200000DRemoteAread-writecurrentNID Series card Port 8 L2CP Mode 0180C200000D 0: Forward 1: Discard 2: Peer
1.3.6.1.4.1.4756.20.501.20.1.1909ColumnnidL2CPPort8DMAC0180C200000ERemoteAread-writecurrentNID Series card Port 8 L2CP Mode 0180C200000E 0: Forward 1: Discard 2: Peer
1.3.6.1.4.1.4756.20.501.20.1.1910ColumnnidL2CPPort8DMAC0180C200000FRemoteAread-writecurrentNID Series card Port 8 L2CP Mode 0180C200000F 0: Forward 1: Discard 2: Peer
1.3.6.1.4.1.4756.20.501.20.1.1911ColumnnidL2CPPort8DMAC0180C2000010RemoteAread-writecurrentNID Series card Port 8 L2CP Mode 0180C2000010 0: Forward 1: Discard 2: Peer
1.3.6.1.4.1.4756.20.501.20.1.1912ColumnnidL2CPPort8DMAC0180C2000020RemoteAread-writecurrentNID Series card Port 8 L2CP Mode 0180C2000020 0: Forward 1: Discard 2: Peer
1.3.6.1.4.1.4756.20.501.20.1.1913ColumnnidL2CPPort8DMAC0180C2000021RemoteAread-writecurrentNID Series card Port 8 L2CP Mode 0180C2000021 0: Forward 1: Discard 2: Peer
1.3.6.1.4.1.4756.20.501.20.1.1914ColumnnidL2CPPort8DMAC0180C2000022RemoteAread-writecurrentNID Series card Port 8 L2CP Mode 0180C2000022 0: Forward 1: Discard 2: Peer
1.3.6.1.4.1.4756.20.501.20.1.1915ColumnnidL2CPPort8DMAC0180C2000023RemoteAread-writecurrentNID Series card Port 8 L2CP Mode 0180C2000023 0: Forward 1: Discard 2: Peer
1.3.6.1.4.1.4756.20.501.20.1.1916ColumnnidL2CPPort8DMAC0180C2000024RemoteAread-writecurrentNID Series card Port 8 L2CP Mode 0180C2000024 0: Forward 1: Discard 2: Peer
1.3.6.1.4.1.4756.20.501.20.1.1917ColumnnidL2CPPort8DMAC0180C2000025RemoteAread-writecurrentNID Series card Port 8 L2CP Mode 0180C2000025 0: Forward 1: Discard 2: Peer
1.3.6.1.4.1.4756.20.501.20.1.1918ColumnnidL2CPPort8DMAC0180C2000026RemoteAread-writecurrentNID Series card Port 8 L2CP Mode 0180C2000026 0: Forward 1: Discard 2: Peer
1.3.6.1.4.1.4756.20.501.20.1.1919ColumnnidL2CPPort8DMAC0180C2000027RemoteAread-writecurrentNID Series card Port 8 L2CP Mode 0180C2000027 0: Forward 1: Discard 2: Peer
1.3.6.1.4.1.4756.20.501.20.1.1920ColumnnidL2CPPort8DMAC0180C2000028RemoteAread-writecurrentNID Series card Port 8 L2CP Mode 0180C2000028 0: Forward 1: Discard 2: Peer
1.3.6.1.4.1.4756.20.501.20.1.1921ColumnnidL2CPPort8DMAC0180C2000029RemoteAread-writecurrentNID Series card Port 8 L2CP Mode 0180C2000029 0: Forward 1: Discard 2: Peer
1.3.6.1.4.1.4756.20.501.20.1.1922ColumnnidL2CPPort8DMAC0180C200002ARemoteAread-writecurrentNID Series card Port 8 L2CP Mode 0180C200002A 0: Forward 1: Discard 2: Peer
1.3.6.1.4.1.4756.20.501.20.1.1923ColumnnidL2CPPort8DMAC0180C200002BRemoteAread-writecurrentNID Series card Port 8 L2CP Mode 0180C200002B 0: Forward 1: Discard 2: Peer
1.3.6.1.4.1.4756.20.501.20.1.1924ColumnnidL2CPPort8DMAC0180C200002CRemoteAread-writecurrentNID Series card Port 8 L2CP Mode 0180C200002C 0: Forward 1: Discard 2: Peer
1.3.6.1.4.1.4756.20.501.20.1.1925ColumnnidL2CPPort8DMAC0180C200002DRemoteAread-writecurrentNID Series card Port 8 L2CP Mode 0180C200002D 0: Forward 1: Discard 2: Peer
1.3.6.1.4.1.4756.20.501.20.1.1926ColumnnidL2CPPort8DMAC0180C200002ERemoteAread-writecurrentNID Series card Port 8 L2CP Mode 0180C200002E 0: Forward 1: Discard 2: Peer
1.3.6.1.4.1.4756.20.501.20.1.1927ColumnnidL2CPPort8DMAC0180C200002FRemoteAread-writecurrentNID Series card Port 8 L2CP Mode 0180C200002F 0: Forward 1: Discard 1: Peer
1.3.6.1.4.1.4756.20.501.20.1.1928ColumnnidFx1DDRemoteAread-onlycurrentNID Series card fiber port Digital Diagnostic function: 0:No 1:Yes
1.3.6.1.4.1.4756.20.501.20.1.1929ColumnnidFx1DDVendorRemoteAread-onlycurrentNID Series card fiber port D/D information: Vendor name
1.3.6.1.4.1.4756.20.501.20.1.1930ColumnnidFx1DDPartNoRemoteAread-onlycurrentNID Series card fiber port D/D information: Vendor part number
1.3.6.1.4.1.4756.20.501.20.1.1931ColumnnidFx1DDFiberTypeRemoteAread-onlycurrentNID Series card fiber port D/D information: Fiber Type
1.3.6.1.4.1.4756.20.501.20.1.1932ColumnnidFx1DDWaveLenRemoteAread-onlycurrentNID Series card fiber port D/D information: Wave length
1.3.6.1.4.1.4756.20.501.20.1.1933ColumnnidFx1DDWaveLen2RemoteAread-onlycurrentNID Series card fiber port D/D information: Wave length 2
1.3.6.1.4.1.4756.20.501.20.1.1934ColumnnidFx1DDLinkLenRemoteAread-onlycurrentNID Series card fiber port D/D information: Link length
1.3.6.1.4.1.4756.20.501.20.1.1935ColumnnidFx1DDLenUnitRemoteAread-onlycurrentNID Series card fiber port D/D information: Length Unit
1.3.6.1.4.1.4756.20.501.20.1.1936ColumnnidFx1DDStatusRemoteAread-onlycurrentNID Series card fiber port D/D information: Status Support
1.3.6.1.4.1.4756.20.501.20.1.1937ColumnnidFx1DDRxSensRemoteAread-onlycurrentNID Series card fiber port D/D information: Rx Sensitivity
1.3.6.1.4.1.4756.20.501.20.1.1938ColumnnidFx1DDTxPWRRemoteAread-onlycurrentNID Series card fiber port D/D information: Tx power
1.3.6.1.4.1.4756.20.501.20.1.1939ColumnnidFx1DDRxPWRRemoteAread-onlycurrentNID Series card fiber port D/D information: Rx power
1.3.6.1.4.1.4756.20.501.20.1.1940ColumnnidFx1DDTempRemoteAread-onlycurrentNID Series card fiber port D/D information: Temperature in degree C
1.3.6.1.4.1.4756.20.501.20.1.1941ColumnnidFx1DDPWRMarginRemoteAread-onlycurrentNID Series card fiber port D/D information: Power margin
1.3.6.1.4.1.4756.20.501.20.1.1942ColumnnidFx1DDPWRLossRemoteAread-onlycurrentNID Series card fiber port D/D information: Power loss
1.3.6.1.4.1.4756.20.501.20.1.1943ColumnnidFx2DDRemoteAread-onlycurrentNID Series card fiber2 Digital Diagnostic function: 0:NO 1:Yes
1.3.6.1.4.1.4756.20.501.20.1.1944ColumnnidFx2DDVendorRemoteAread-onlycurrentNID Series card fiber2 D/D information: Vendor name
1.3.6.1.4.1.4756.20.501.20.1.1945ColumnnidFx2DDPartNoRemoteAread-onlycurrentNID Series card fiber2 D/D information: Vendor part number
1.3.6.1.4.1.4756.20.501.20.1.1946ColumnnidFx2DDFiberTypeRemoteAread-onlycurrentNID Series card fiber2 D/D information: Fiber Type
1.3.6.1.4.1.4756.20.501.20.1.1947ColumnnidFx2DDWaveLenRemoteAread-onlycurrentNID Series card fiber2 D/D information: Wave length 1
1.3.6.1.4.1.4756.20.501.20.1.1948ColumnnidFx2DDWaveLen2RemoteAread-onlycurrentNID Series card fiber2 D/D information: Wave length 2
1.3.6.1.4.1.4756.20.501.20.1.1949ColumnnidFx2DDLinkLenRemoteAread-onlycurrentNID Series card fiber2 D/D information: Link length
1.3.6.1.4.1.4756.20.501.20.1.1950ColumnnidFx2DDLenUnitRemoteAread-onlycurrentNID Series card fiber2 D/D information: Length Unit
1.3.6.1.4.1.4756.20.501.20.1.1951ColumnnidFx2DDStatusRemoteAread-onlycurrentNID Series card fiber2 D/D information: Status Support
1.3.6.1.4.1.4756.20.501.20.1.1952ColumnnidFx2DDRxSensRemoteAread-onlycurrentNID Series card fiber2 D/D information: Rx Sensitivity
1.3.6.1.4.1.4756.20.501.20.1.1953ColumnnidFx2DDTxPWRRemoteAread-onlycurrentNID Series card fiber2 D/D information: Tx power
1.3.6.1.4.1.4756.20.501.20.1.1954ColumnnidFx2DDRxPWRRemoteAread-onlycurrentNID Series card fiber2 D/D information: Rx power
1.3.6.1.4.1.4756.20.501.20.1.1955ColumnnidFx2DDTempRemoteAread-onlycurrentNID Series card fiber2 D/D information: Temperature in degree C
1.3.6.1.4.1.4756.20.501.20.1.1956ColumnnidFx2DDPWRMarginRemoteAread-onlycurrentNID Series card fiber2 D/D information: Power margin
1.3.6.1.4.1.4756.20.501.20.1.1957ColumnnidFx2DDPWRLossRemoteAread-onlycurrentNID Series card fiber2 D/D information: Power loss
1.3.6.1.4.1.4756.20.501.20.1.1958ColumnnidFx3DDRemoteAread-onlycurrentNID Series card fiber3 Digital Diagnostic function: 0:NO 1:Yes
1.3.6.1.4.1.4756.20.501.20.1.1959ColumnnidFx3DDVendorRemoteAread-onlycurrentNID Series card fiber3 D/D information: Vendor name
1.3.6.1.4.1.4756.20.501.20.1.1960ColumnnidFx3DDPartNoRemoteAread-onlycurrentNID Series card fiber32 D/D information: Vendor part number
1.3.6.1.4.1.4756.20.501.20.1.1961ColumnnidFx3DDFiberTypeRemoteAread-onlycurrentNID Series card fiber3 D/D information: Fiber Type
1.3.6.1.4.1.4756.20.501.20.1.1962ColumnnidFx3DDWaveLenRemoteAread-onlycurrentNID Series card fiber3 D/D information: Wave length 1
1.3.6.1.4.1.4756.20.501.20.1.1963ColumnnidFx3DDWaveLen2RemoteAread-onlycurrentNID Series card fiber3 D/D information: Wave length 2
1.3.6.1.4.1.4756.20.501.20.1.1964ColumnnidFx3DDLinkLenRemoteAread-onlycurrentNID Series card fiber3 D/D information: Link length
1.3.6.1.4.1.4756.20.501.20.1.1965ColumnnidFx3DDLenUnitRemoteAread-onlycurrentNID Series card fiber3 D/D information: Length Unit
1.3.6.1.4.1.4756.20.501.20.1.1966ColumnnidFx3DDStatusRemoteAread-onlycurrentNID Series card fiber3 D/D information: Status Support
1.3.6.1.4.1.4756.20.501.20.1.1967ColumnnidFx3DDRxSensRemoteAread-onlycurrentNID Series card fiber3 D/D information: Rx Sensitivity
1.3.6.1.4.1.4756.20.501.20.1.1968ColumnnidFx3DDTxPWRRemoteAread-onlycurrentNID Series card fiber3 D/D information: Tx power
1.3.6.1.4.1.4756.20.501.20.1.1969ColumnnidFx3DDRxPWRRemoteAread-onlycurrentNID Series card fiber3 D/D information: Rx power
1.3.6.1.4.1.4756.20.501.20.1.1970ColumnnidFx3DDTempRemoteAread-onlycurrentNID Series card fiber3 D/D information: Temperature in degree C
1.3.6.1.4.1.4756.20.501.20.1.1971ColumnnidFx3DDPWRMarginRemoteAread-onlycurrentNID Series card fiber3 D/D information: Power margin
1.3.6.1.4.1.4756.20.501.20.1.1972ColumnnidFx3DDPWRLossRemoteAread-onlycurrentNID Series card fiber3 D/D information: Power loss
1.3.6.1.4.1.4756.20.501.20.1.1973ColumnnidFx4DDRemoteAread-onlycurrentNID Series card fiber4 Digital Diagnostic function: 0:NO 1:Yes
1.3.6.1.4.1.4756.20.501.20.1.1974ColumnnidFx4DDVendorRemoteAread-onlycurrentNID Series card fiber4 D/D information: Vendor name
1.3.6.1.4.1.4756.20.501.20.1.1975ColumnnidFx4DDPartNoRemoteAread-onlycurrentNID Series card fiber4 D/D information: Vendor part number
1.3.6.1.4.1.4756.20.501.20.1.1976ColumnnidFx4DDFiberTypeRemoteAread-onlycurrentNID Series card fiber4 D/D information: Fiber Type
1.3.6.1.4.1.4756.20.501.20.1.1977ColumnnidFx4DDWaveLenRemoteAread-onlycurrentNID Series card fiber4 D/D information: Wave length 1
1.3.6.1.4.1.4756.20.501.20.1.1978ColumnnidFx4DDWaveLen2RemoteAread-onlycurrentNID Series card fiber4 D/D information: Wave length 2
1.3.6.1.4.1.4756.20.501.20.1.1979ColumnnidFx4DDLinkLenRemoteAread-onlycurrentNID Series card fiber4 D/D information: Link length
1.3.6.1.4.1.4756.20.501.20.1.1980ColumnnidFx4DDLenUnitRemoteAread-onlycurrentNID Series card fiber4 D/D information: Length Unit
1.3.6.1.4.1.4756.20.501.20.1.1981ColumnnidFx4DDStatusRemoteAread-onlycurrentNID Series card fiber4 D/D information: Status Support
1.3.6.1.4.1.4756.20.501.20.1.1982ColumnnidFx4DDRxSensRemoteAread-onlycurrentNID Series card fiber4 D/D information: Rx Sensitivity
1.3.6.1.4.1.4756.20.501.20.1.1983ColumnnidFx4DDTxPWRRemoteAread-onlycurrentNID Series card fiber4 D/D information: Tx power
1.3.6.1.4.1.4756.20.501.20.1.1984ColumnnidFx4DDRxPWRRemoteAread-onlycurrentNID Series card fiber4 D/D information: Rx power
1.3.6.1.4.1.4756.20.501.20.1.1985ColumnnidFx4DDTempRemoteAread-onlycurrentNID Series card fiber4 D/D information: Temperature in degree C
1.3.6.1.4.1.4756.20.501.20.1.1986ColumnnidFx4DDPWRMarginRemoteAread-onlycurrentNID Series card fiber4 D/D information: Power margin
1.3.6.1.4.1.4756.20.501.20.1.1987ColumnnidFx4DDPWRLossRemoteAread-onlycurrentNID Series card fiber4 D/D information: Power loss
1.3.6.1.4.1.4756.20.501.20.1.1988ColumnnidDeviceActiveRemoteAread-writecurrentNID Series card u-Ring device active 0: Disable 1: Enable
1.3.6.1.4.1.4756.20.501.20.1.1989ColumnnidSaveStartupCongRemoteAread-writecurrentNID Series card save start-up config 0: OFF 1: Action
1.3.6.1.4.1.4756.20.501.20.1.1990ColumnnidPortResetRemoteAread-writecurrentNID Series card port reset 0: OFF 1: Action
1.3.6.1.4.1.4756.20.501.20.1.1991ColumnnidSetDefaultRemoteAread-writecurrentNID Series card set to default config 0: OFF 1: Action
1.3.6.1.4.1.4756.20.501.20.1.1992ColumnnidSetDefault2RemoteAread-writecurrentNID Series card set to default config (Without OAM) 0: OFF 1: Action
1.3.6.1.4.1.4756.20.501.20.1.1993ColumnnidClearPortCounterRemoteAread-writecurrentNID Series card clear port counter: 0: Off 1: Action
1.3.6.1.4.1.4756.20.501.20.1.1994ColumnnidClearOAMCounterRemoteAread-writecurrentNID Series card Clear OAM Counter: 0: Off 1: Action
1.3.6.1.4.1.4756.20.501.20.1.1995ColumnnidSTPStatisticsPortClearCounterRemoteAread-writecurrentNID Series card STP Port Statistics: Clear Counters 0: OFff 1: Action
1.3.6.1.4.1.4756.20.501.20.1.1996ColumnnidAlarmRemoteAread-onlycurrentNID Series card Alarm led status: 0: Off 1: On
1.3.6.1.4.1.4756.20.501.20.1.1997ColumnnidTest1RemoteAread-onlycurrentNID Series card Test1 led status: 0: Off 1: On
1.3.6.1.4.1.4756.20.501.20.1.1998ColumnnidTest2RemoteAread-onlycurrentNID Series card Test2 led status: 0: Off 1: On
1.3.6.1.4.1.4756.20.502NodenidRemoteBCards
1.3.6.1.4.1.4756.20.502.20TablenidRemoteBTablenot-accessiblecurrentA list of RemoteB FRM220-MSW404/MSW404S card entries. The number of entries is f16G3R-No-L.
1.3.6.1.4.1.4756.20.502.20.1RownidRemoteBEntrynot-accessiblecurrentAn entry containing management information applicable to a particular RemoteB FRM220-MSW404/MSW404S card.
1.3.6.1.4.1.4756.20.502.20.1.1ColumnnidChassisIndexRemoteBread-onlycurrentA unique value for each RemoteB card. It is the chassis location number.
1.3.6.1.4.1.4756.20.502.20.1.2ColumnnidSlotIndexRemoteBread-onlycurrentA unique value for each RemoteB card. It is the slot location number.
1.3.6.1.4.1.4756.20.502.20.1.3ColumnnidCardHWVerRemoteBread-onlycurrentRemoteB NID card hardware version x.xxx
1.3.6.1.4.1.4756.20.502.20.1.4ColumnnidCardFWVerRemoteBread-onlycurrentRemoteB NID card firmware version x.xxx
1.3.6.1.4.1.4756.20.502.20.1.5ColumnnidCardCPLDVerRemoteBread-onlycurrentRemoteB NID card CPLD version x.xxx
1.3.6.1.4.1.4756.20.502.20.1.6ColumnnidCardFPGAVerRemoteBread-onlycurrentRemoteB NID card FPGA version x.xxx
1.3.6.1.4.1.4756.20.502.20.1.7ColumnnidModelRemoteBread-onlycurrentCard Type: 0:MSW404 1:MSW404S
1.3.6.1.4.1.4756.20.502.20.1.8ColumnnidDNSServerTypeRemoteBread-writecurrentNID Series card IP Configuration: This setting controls the DNS name resolution done by the switch. The following modes are supported: 1:From any DHCP interfac…
1.3.6.1.4.1.4756.20.502.20.1.9ColumnnidDNSServerSettingRemoteBread-writecurrentNID Series card IP Configuration: If iDNSServerType setting '3:Configured',this value must setting IP address format as below: Dotted Decimal Notation refers t…
1.3.6.1.4.1.4756.20.502.20.1.10ColumnnidDNSproxyRemoteBread-writecurrentNID Series card IP Configuration: When DNS proxy is enabled, system will relay DNS requests to the currently configured DNS server, and reply as a DNS resolver…
1.3.6.1.4.1.4756.20.502.20.1.11ColumnnidAddIPV4InterfaceRemoteBread-writecurrentNID Series card IP Interfaces: Add a new IP VLAN Interface: Syntax: [<Interface>] [<vlan_list>] [<IPV4_Addr>] [<IPV4_MASK>] Interface : 1~4
1.3.6.1.4.1.4756.20.502.20.1.12ColumnnidDeleteInterfaceRemoteBread-writecurrentNID Series card IP Interfaces: Delete a IPv4/v6 VLAN Interface: Syntax: [<Interface>] Interface: 1~4
1.3.6.1.4.1.4756.20.502.20.1.13ColumnnidIPInterface1VLANRemoteBread-onlycurrentNID Series card IP Interfaces: The VLAN associated with the IP interface. Only ports in this VLAN will be able to access the IP interface. This field is only a…
1.3.6.1.4.1.4756.20.502.20.1.14ColumnnidIPInterface1DHCPRemoteBread-writecurrentNID Series card IP Interfaces: DHCP
1.3.6.1.4.1.4756.20.502.20.1.15ColumnnidIPInterface1FallbackRemoteBread-writecurrentNID Series card IP Interfaces: Fallback
1.3.6.1.4.1.4756.20.502.20.1.16ColumnnidIPInterface1IPV4AddressRemoteBread-onlycurrentNID Series card IP Interfaces: IPV4 Address
1.3.6.1.4.1.4756.20.502.20.1.17ColumnnidIPInterface1IPV4MASKLenRemoteBread-onlycurrentNID Series card IP Interfaces: IPV4 MASK Length
1.3.6.1.4.1.4756.20.502.20.1.18ColumnnidIPInterface2VLANRemoteBread-onlycurrentNID Series card IP Interfaces: The VLAN associated with the IP interface. Only ports in this VLAN will be able to access the IP interface. This field is only a…
1.3.6.1.4.1.4756.20.502.20.1.19ColumnnidIPInterface2DHCPRemoteBread-writecurrentNID Series card IP Interfaces: DHCP
1.3.6.1.4.1.4756.20.502.20.1.20ColumnnidIPInterface2FallbackRemoteBread-writecurrentNID Series card IP Interfaces: Fallback
1.3.6.1.4.1.4756.20.502.20.1.21ColumnnidIPInterface2IPV4AddressRemoteBread-onlycurrentNID Series card IP Interfaces: IPV4 Address
1.3.6.1.4.1.4756.20.502.20.1.22ColumnnidIPInterface2IPV4MASKLenRemoteBread-onlycurrentNID Series card IP Interfaces: IPV4 MASK Length
1.3.6.1.4.1.4756.20.502.20.1.23ColumnnidIPInterface3VLANRemoteBread-onlycurrentNID Series card IP Interfaces: The VLAN associated with the IP interface. Only ports in this VLAN will be able to access the IP interface. This field is only a…
1.3.6.1.4.1.4756.20.502.20.1.24ColumnnidIPInterface3DHCPRemoteBread-writecurrentNID Series card IP Interfaces: DHCP
1.3.6.1.4.1.4756.20.502.20.1.25ColumnnidIPInterface3FallbackRemoteBread-writecurrentNID Series card IP Interfaces: Fallback
1.3.6.1.4.1.4756.20.502.20.1.26ColumnnidIPInterface3IPV4AddressRemoteBread-onlycurrentNID Series card IP Interfaces: IPV4 Address
1.3.6.1.4.1.4756.20.502.20.1.27ColumnnidIPInterface3IPV4MASKLenRemoteBread-onlycurrentNID Series card IP Interfaces: IPV4 MASK Length
1.3.6.1.4.1.4756.20.502.20.1.28ColumnnidIPInterface4VLANRemoteBread-onlycurrentNID Series card IP Interfaces: The VLAN associated with the IP interface. Only ports in this VLAN will be able to access the IP interface. This field is only a…
1.3.6.1.4.1.4756.20.502.20.1.29ColumnnidIPInterface4DHCPRemoteBread-writecurrentNID Series card IP Interfaces: DHCP
1.3.6.1.4.1.4756.20.502.20.1.30ColumnnidIPInterface4FallbackRemoteBread-writecurrentNID Series card IP Interfaces: Fallback
1.3.6.1.4.1.4756.20.502.20.1.31ColumnnidIPInterface4IPV4AddressRemoteBread-onlycurrentNID Series card IP Interfaces: IPV4 Address
1.3.6.1.4.1.4756.20.502.20.1.32ColumnnidIPInterface4IPV4MASKLenRemoteBread-onlycurrentNID Series card IP Interfaces: IPV4 MASK Length
1.3.6.1.4.1.4756.20.502.20.1.33ColumnnidAddIPV6InterfaceRemoteBread-writecurrentNID Series card IP Interfaces: Add a new IPv6 VLAN Interface: Syntax: [<Interface>] [<vlan_list>] [<IPV4_Addr>] [<IPV4_MASK>] Interface : 1~4
1.3.6.1.4.1.4756.20.502.20.1.34ColumnnidIPInterface1IPV6AddressRemoteBread-onlycurrentNID Series card IP Interfaces: IPV6 Address
1.3.6.1.4.1.4756.20.502.20.1.35ColumnnidIPInterface1IPV6MASKLenRemoteBread-onlycurrentNID Series card IP Interfaces: IPV6 MASK Length
1.3.6.1.4.1.4756.20.502.20.1.36ColumnnidIPInterface2IPV6AddressRemoteBread-onlycurrentNID Series card IP Interfaces: IPV6 Address
1.3.6.1.4.1.4756.20.502.20.1.37ColumnnidIPInterface2IPV6MASKLenRemoteBread-onlycurrentNID Series card IP Interfaces: IPV6 MASK Length
1.3.6.1.4.1.4756.20.502.20.1.38ColumnnidIPInterface3IPV6AddressRemoteBread-onlycurrentNID Series card IP Interfaces: IPV6 Address
1.3.6.1.4.1.4756.20.502.20.1.39ColumnnidIPInterface3IPV6MASKLenRemoteBread-onlycurrentNID Series card IP Interfaces: IPV6 MASK Length
1.3.6.1.4.1.4756.20.502.20.1.40ColumnnidIPInterface4IPV6AddressRemoteBread-onlycurrentNID Series card IP Interfaces: IPV6 Address
1.3.6.1.4.1.4756.20.502.20.1.41ColumnnidIPInterface4IPV6MASKLenRemoteBread-onlycurrentNID Series card IP Interfaces: IPV6 MASK Length
1.3.6.1.4.1.4756.20.502.20.1.42ColumnnidPort1LinkstsRemoteBread-onlycurrentNID Series card Port1 link status: 0:Link down 1:Link up
1.3.6.1.4.1.4756.20.502.20.1.43ColumnnidPort1SpeedstsRemoteBread-onlycurrentNID Series card Port1 speed status 10Base-T 100Base-Tx 1000Base-Tx 2.5G
1.3.6.1.4.1.4756.20.502.20.1.44ColumnnidPort1DuplexstsRemoteBread-onlycurrentNID Series card Port1 duplex status 0: Half 1: Full
1.3.6.1.4.1.4756.20.502.20.1.45ColumnnidPort1RxPausestsRemoteBread-onlycurrentNID Series card Port1 rx pause status 0: No 1: Yes
1.3.6.1.4.1.4756.20.502.20.1.46ColumnnidPort1TxPausestsRemoteBread-onlycurrentNID Series card Port1 tx pause status 0: No 1: Yes
1.3.6.1.4.1.4756.20.502.20.1.47ColumnnidPort2LinkstsRemoteBread-onlycurrentNID Series card Port2 link status: 0:Link down 1:Link up
1.3.6.1.4.1.4756.20.502.20.1.48ColumnnidPort2SpeedstsRemoteBread-onlycurrentNID Series card Port2 speed status 10Base-T 100Base-Tx 1000Base-Tx 2.5G
1.3.6.1.4.1.4756.20.502.20.1.49ColumnnidPort2DuplexstsRemoteBread-onlycurrentNID Series card Port2 duplex status 0: Half 1: Full
1.3.6.1.4.1.4756.20.502.20.1.50ColumnnidPort2RxPausestsRemoteBread-onlycurrentNID Series card Port2 rx pause status 0: No 1: Yes
1.3.6.1.4.1.4756.20.502.20.1.51ColumnnidPort2TxPausestsRemoteBread-onlycurrentNID Series card Port2 tx pause status 0: No 1: Yes
1.3.6.1.4.1.4756.20.502.20.1.52ColumnnidPort3LinkstsRemoteBread-onlycurrentNID Series card Port3 link status: 0:Link down 1:Link up
1.3.6.1.4.1.4756.20.502.20.1.53ColumnnidPort3SpeedstsRemoteBread-onlycurrentNID Series card Port3 speed status 10Base-T 100Base-Tx 1000Base-Tx
1.3.6.1.4.1.4756.20.502.20.1.54ColumnnidPort3DuplexstsRemoteBread-onlycurrentNID Series card Port3 duplex status 0: Half 1: Full
1.3.6.1.4.1.4756.20.502.20.1.55ColumnnidPort3RxPausestsRemoteBread-onlycurrentNID Series card Port3 rx pause status 0: No 1: Yes
1.3.6.1.4.1.4756.20.502.20.1.56ColumnnidPort3TxPausestsRemoteBread-onlycurrentNID Series card Port3 tx pause status 0: No 1: Yes
1.3.6.1.4.1.4756.20.502.20.1.57ColumnnidPort4LinkstsRemoteBread-onlycurrentNID Series card Port4 link status: 0:Link down 1:Link up
1.3.6.1.4.1.4756.20.502.20.1.58ColumnnidPort4SpeedstsRemoteBread-onlycurrentNID Series card Port4 speed status 10Base-T 100Base-Tx 1000Base-Tx
1.3.6.1.4.1.4756.20.502.20.1.59ColumnnidPort4DuplexstsRemoteBread-onlycurrentNID Series card Port4 duplex status 0: Half 1: Full
1.3.6.1.4.1.4756.20.502.20.1.60ColumnnidPort4RxPausestsRemoteBread-onlycurrentNID Series card Port4 rx pause status 0: No 1: Yes
1.3.6.1.4.1.4756.20.502.20.1.61ColumnnidPort4TxPausestsRemoteBread-onlycurrentNID Series card Port4 tx pause status 0: No 1: Yes
1.3.6.1.4.1.4756.20.502.20.1.62ColumnnidPort5LinkstsRemoteBread-onlycurrentNID Series card Port5 link status: 0:Link down 1:Link up
1.3.6.1.4.1.4756.20.502.20.1.63ColumnnidPort5SpeedstsRemoteBread-onlycurrentNID Series card Port5 speed status 10Base-T 100Base-Tx 1000Base-Tx
1.3.6.1.4.1.4756.20.502.20.1.64ColumnnidPort5DuplexstsRemoteBread-onlycurrentNID Series card Port5 duplex status 0: Half 1: Full
1.3.6.1.4.1.4756.20.502.20.1.65ColumnnidPort5RxPausestsRemoteBread-onlycurrentNID Series card Port5 rx pause status 0: No 1: Yes
1.3.6.1.4.1.4756.20.502.20.1.66ColumnnidPort5TxPausestsRemoteBread-onlycurrentNID Series card Port5 tx pause status 0: No 1: Yes
1.3.6.1.4.1.4756.20.502.20.1.67ColumnnidPort6LinkstsRemoteBread-onlycurrentNID Series card Port6 link status: 0:Link down 1:Link up
1.3.6.1.4.1.4756.20.502.20.1.68ColumnnidPort6SpeedstsRemoteBread-onlycurrentNID Series card Port6 speed status 10Base-T 100Base-Tx 1000Base-Tx
1.3.6.1.4.1.4756.20.502.20.1.69ColumnnidPort6DuplexstsRemoteBread-onlycurrentNID Series card Port6 duplex status 0: Half 1: Full
1.3.6.1.4.1.4756.20.502.20.1.70ColumnnidPort6RxPausestsRemoteBread-onlycurrentNID Series card Port6 rx pause status 0: No 1: Yes
1.3.6.1.4.1.4756.20.502.20.1.71ColumnnidPort6TxPausestsRemoteBread-onlycurrentNID Series card Port6 tx pause status 0: No 1: Yes
1.3.6.1.4.1.4756.20.502.20.1.72ColumnnidPort7LinkstsRemoteBread-onlycurrentNID Series card Port7 link status: 0:Link down 1:Link up
1.3.6.1.4.1.4756.20.502.20.1.73ColumnnidPort7SpeedstsRemoteBread-onlycurrentNID Series card Port7 speed status 10Base-T 100Base-Tx 1000Base-Tx
1.3.6.1.4.1.4756.20.502.20.1.74ColumnnidPort7DuplexstsRemoteBread-onlycurrentNID Series card Port7 duplex status 0: Half 1: Full
1.3.6.1.4.1.4756.20.502.20.1.75ColumnnidPort7RxPausestsRemoteBread-onlycurrentNID Series card Port7 rx pause status 0: No 1: Yes
1.3.6.1.4.1.4756.20.502.20.1.76ColumnnidPort7TxPausestsRemoteBread-onlycurrentNID Series card Port7 tx pause status 0: No 1: Yes
1.3.6.1.4.1.4756.20.502.20.1.77ColumnnidPort8LinkstsRemoteBread-onlycurrentNID Series card Port8 link status: 0:Link down 1:Link up
1.3.6.1.4.1.4756.20.502.20.1.78ColumnnidPort8SpeedstsRemoteBread-onlycurrentNID Series card Port8 speed status 10Base-T 100Base-Tx 1000Base-Tx
1.3.6.1.4.1.4756.20.502.20.1.79ColumnnidPort8DuplexstsRemoteBread-onlycurrentNID Series card Port8 duplex status 0: Half 1: Full
1.3.6.1.4.1.4756.20.502.20.1.80ColumnnidPort8RxPausestsRemoteBread-onlycurrentNID Series card Port8 rx pause status 0: No 1: Yes
1.3.6.1.4.1.4756.20.502.20.1.81ColumnnidPort8TxPausestsRemoteBread-onlycurrentNID Series card Port8 tx pause status 0: No 1: Yes
1.3.6.1.4.1.4756.20.502.20.1.82ColumnnidPort1SpeedConfRemoteBread-writecurrentNID Series card Port1 speed config 0: disable 1: auto 2: 100M FDX 3: 1G FDX 4: 2.5G FDX
1.3.6.1.4.1.4756.20.502.20.1.83ColumnnidPort1flowConrolRemoteBread-writecurrentNID Series card Port1 flow control config 0: no 1: yes
1.3.6.1.4.1.4756.20.502.20.1.84ColumnnidPort1MaxFrameRemoteBread-writecurrentNID Series card Port1 max frame config
1.3.6.1.4.1.4756.20.502.20.1.85ColumnnidPort1ALSRemoteBread-writecurrentNID Series card Port1 auto laser shutdown: 0: Disable 1: Enable
1.3.6.1.4.1.4756.20.502.20.1.86ColumnnidPort2SpeedConfRemoteBread-writecurrentNID Series card Port2 speed config 0: disable 1: auto 2: 100M FDX 3: 1G FDX 4: 2.5G FDX
1.3.6.1.4.1.4756.20.502.20.1.87ColumnnidPort2flowConrolRemoteBread-writecurrentNID Series card Port2 flow control config 0: no 1: yes
1.3.6.1.4.1.4756.20.502.20.1.88ColumnnidPort2MaxFrameRemoteBread-writecurrentNID Series card Port2 max frame config
1.3.6.1.4.1.4756.20.502.20.1.89ColumnnidPort2ALSRemoteBread-writecurrentNID Series card Port2 auto laser shutdown: 0: Disable 1: Enable
1.3.6.1.4.1.4756.20.502.20.1.90ColumnnidPort3SpeedConfRemoteBread-writecurrentNID Series card Port3 speed config 0: disable 1: auto 2: 100M FDX 3: 1G FDX
1.3.6.1.4.1.4756.20.502.20.1.91ColumnnidPort3flowConrolRemoteBread-writecurrentNID Series card Port3 flow control config 0: no 1: yes
1.3.6.1.4.1.4756.20.502.20.1.92ColumnnidPort3MaxFrameRemoteBread-writecurrentNID Series card Port3 max frame config
1.3.6.1.4.1.4756.20.502.20.1.93ColumnnidPort3ALSRemoteBread-writecurrentNID Series card Port3 auto laser shutdown: 0: Disable 1: Enable
1.3.6.1.4.1.4756.20.502.20.1.94ColumnnidPort4SpeedConfRemoteBread-writecurrentNID Series card Port4 speed config 0: disable 1: auto 2: 100M FDX 3: 1G FDX
1.3.6.1.4.1.4756.20.502.20.1.95ColumnnidPort4flowConrolRemoteBread-writecurrentNID Series card Port4 flow control config 0: no 1: yes
1.3.6.1.4.1.4756.20.502.20.1.96ColumnnidPort4MaxFrameRemoteBread-writecurrentNID Series card Port4 max frame config
1.3.6.1.4.1.4756.20.502.20.1.97ColumnnidPort4ALSRemoteBread-writecurrentNID Series card Port4 auto laser shutdown: 0: Disable 1: Enable
1.3.6.1.4.1.4756.20.502.20.1.98ColumnnidPort5SpeedConfRemoteBread-writecurrentNID Series card Port5 speed config 0: disable 1: auto 2: 10M HDX 3: 10M FDX 4: 100M HDX 5: 100M FDX 6: 1G FDX
1.3.6.1.4.1.4756.20.502.20.1.99ColumnnidPort5flowConrolRemoteBread-writecurrentNID Series card Port5 flow control config 0: no 1: yes
1.3.6.1.4.1.4756.20.502.20.1.100ColumnnidPort5MaxFrameRemoteBread-writecurrentNID Series card Port5 max frame config
1.3.6.1.4.1.4756.20.502.20.1.101ColumnnidPort5CollisionModeRemoteBread-writecurrentNID Series card Port5 collision mode config. 0: Discard 1: Restart
1.3.6.1.4.1.4756.20.502.20.1.102ColumnnidPort6SpeedConfRemoteBread-writecurrentNID Series card Port6 speed config 0: disable 1: auto 2: 10M HDX 3: 10M FDX 4: 100M HDX 5: 100M FDX 6: 1G FDX
1.3.6.1.4.1.4756.20.502.20.1.103ColumnnidPort6flowConrolRemoteBread-writecurrentNID Series card Port6 flow control config 0: no 1: yes
1.3.6.1.4.1.4756.20.502.20.1.104ColumnnidPort6MaxFrameRemoteBread-writecurrentNID Series card Port6 max frame config
1.3.6.1.4.1.4756.20.502.20.1.105ColumnnidPort6CollisionModeRemoteBread-writecurrentNID Series card Port6 collision mode config. 0: Discard 1: Restart
1.3.6.1.4.1.4756.20.502.20.1.106ColumnnidPort7SpeedConfRemoteBread-writecurrentNID Series card Port7 speed config 0: disable 1: auto 2: 10M HDX 3: 10M FDX 4: 100M HDX 5: 100M FDX 6: 1G FDX
1.3.6.1.4.1.4756.20.502.20.1.107ColumnnidPort7flowConrolRemoteBread-writecurrentNID Series card Port7 flow control config 0: no 1: yes
1.3.6.1.4.1.4756.20.502.20.1.108ColumnnidPort7MaxFrameRemoteBread-writecurrentNID Series card Port7 max frame config
1.3.6.1.4.1.4756.20.502.20.1.109ColumnnidPort7CollisionModeRemoteBread-writecurrentNID Series card Port7 collision mode config. 0: Discard 1: Restart
1.3.6.1.4.1.4756.20.502.20.1.110ColumnnidPort8SpeedConfRemoteBread-writecurrentNID Series card Port8 speed config 0: disable 1: auto 2: 10M HDX 3: 10M FDX 4: 100M HDX 5: 100M FDX 6: 1G FDX
1.3.6.1.4.1.4756.20.502.20.1.111ColumnnidPort8flowConrolRemoteBread-writecurrentNID Series card Port8 flow control config 0: no 1: yes
1.3.6.1.4.1.4756.20.502.20.1.112ColumnnidPort8MaxFrameRemoteBread-writecurrentNID Series card Port8 max frame config
1.3.6.1.4.1.4756.20.502.20.1.113ColumnnidPort8CollisionModeRemoteBread-writecurrentNID Series card Port8 collision mode config. 0: Discard 1: Restart
1.3.6.1.4.1.4756.20.502.20.1.114ColumnnidPort1LLFLogicRemoteBread-writecurrentNID Series card Port1 link loss forwarding - Logic 0: AND 1: OR
1.3.6.1.4.1.4756.20.502.20.1.115ColumnnidPort1LLFLogicPort2RemoteBread-writecurrentNID Series card Port1 link loss forwarding - Link/Rx Loss Port2 0: NO 1: YES
1.3.6.1.4.1.4756.20.502.20.1.116ColumnnidPort1LLFLogicPort3RemoteBread-writecurrentNID Series card Port1 link loss forwarding - Link/Rx Loss Port3 0: NO 1: YES
1.3.6.1.4.1.4756.20.502.20.1.117ColumnnidPort1LLFLogicPort4RemoteBread-writecurrentNID Series card Port1 link loss forwarding - Link/Rx Loss Port4 0: NO 1: YES
1.3.6.1.4.1.4756.20.502.20.1.118ColumnnidPort1LLFLogicPort5RemoteBread-writecurrentNID Series card Port1 link loss forwarding - Link/Rx Loss Port5 0: NO 1: YES
1.3.6.1.4.1.4756.20.502.20.1.119ColumnnidPort1LLFLogicPort6RemoteBread-writecurrentNID Series card Port1 link loss forwarding - Link/Rx Loss Port6 0: NO 1: YES
1.3.6.1.4.1.4756.20.502.20.1.120ColumnnidPort1LLFLogicPort7RemoteBread-writecurrentNID Series card Port1 link loss forwarding - Link/Rx Loss Port7 0: NO 1: YES
1.3.6.1.4.1.4756.20.502.20.1.121ColumnnidPort1LLFLogicPort8RemoteBread-writecurrentNID Series card Port1 link loss forwarding - Link/Rx Loss Port8 0: NO 1: YES
1.3.6.1.4.1.4756.20.502.20.1.122ColumnnidPort2LLFLogicRemoteBread-writecurrentNID Series card Port2 link loss forwarding - Logic 0: AND 1: OR
1.3.6.1.4.1.4756.20.502.20.1.123ColumnnidPort2LLFLogicPort1RemoteBread-writecurrentNID Series card Port2 link loss forwarding - Link/Rx Loss Port1 0: NO 1: YES
1.3.6.1.4.1.4756.20.502.20.1.124ColumnnidPort2LLFLogicPort3RemoteBread-writecurrentNID Series card Port2 link loss forwarding - Link/Rx Loss Port3 0: NO 1: YES
1.3.6.1.4.1.4756.20.502.20.1.125ColumnnidPort2LLFLogicPort4RemoteBread-writecurrentNID Series card Port2 link loss forwarding - Link/Rx Loss Port4 0: NO 1: YES
1.3.6.1.4.1.4756.20.502.20.1.126ColumnnidPort2LLFLogicPort5RemoteBread-writecurrentNID Series card Port2 link loss forwarding - Link/Rx Loss Port54 0: NO 1: YES
1.3.6.1.4.1.4756.20.502.20.1.127ColumnnidPort2LLFLogicPort6RemoteBread-writecurrentNID Series card Port2 link loss forwarding - Link/Rx Loss Port6 0: NO 1: YES
1.3.6.1.4.1.4756.20.502.20.1.128ColumnnidPort2LLFLogicPort7RemoteBread-writecurrentNID Series card Port2 link loss forwarding - Link/Rx Loss Port7 0: NO 1: YES
1.3.6.1.4.1.4756.20.502.20.1.129ColumnnidPort2LLFLogicPort8RemoteBread-writecurrentNID Series card Port2 link loss forwarding - Link/Rx Loss Port8 0: NO 1: YES
1.3.6.1.4.1.4756.20.502.20.1.130ColumnnidPort3LLFLogicRemoteBread-writecurrentNID Series card Port1 link loss forwarding - Logic 0: AND 1: OR
1.3.6.1.4.1.4756.20.502.20.1.131ColumnnidPort3LLFLogicPort1RemoteBread-writecurrentNID Series card Port3 link loss forwarding - Link/Rx Loss Port1 0: NO 1: YES
1.3.6.1.4.1.4756.20.502.20.1.132ColumnnidPort3LLFLogicPort2RemoteBread-writecurrentNID Series card Port3 link loss forwarding - Link/Rx Loss Port2 0: NO 1: YES
1.3.6.1.4.1.4756.20.502.20.1.133ColumnnidPort3LLFLogicPort4RemoteBread-writecurrentNID Series card Port3 link loss forwarding - Link/Rx Loss Port4 0: NO 1: YES
1.3.6.1.4.1.4756.20.502.20.1.134ColumnnidPort3LLFLogicPort5RemoteBread-writecurrentNID Series card Port3 link loss forwarding - Link/Rx Loss Port5 0: NO 1: YES
1.3.6.1.4.1.4756.20.502.20.1.135ColumnnidPort3LLFLogicPort6RemoteBread-writecurrentNID Series card Port3 link loss forwarding - Link/Rx Loss Port6 0: NO 1: YES
1.3.6.1.4.1.4756.20.502.20.1.136ColumnnidPort3LLFLogicPort7RemoteBread-writecurrentNID Series card Port3 link loss forwarding - Link/Rx Loss Port7 0: NO 1: YES
1.3.6.1.4.1.4756.20.502.20.1.137ColumnnidPort3LLFLogicPort8RemoteBread-writecurrentNID Series card Port3 link loss forwarding - Link/Rx Loss Port8 0: NO 1: YES
1.3.6.1.4.1.4756.20.502.20.1.138ColumnnidPort4LLFLogicRemoteBread-writecurrentNID Series card Port4 link loss forwarding - Logic 0: AND 1: OR
1.3.6.1.4.1.4756.20.502.20.1.139ColumnnidPort4LLFLogicPort1RemoteBread-writecurrentNID Series card Port4 link loss forwarding - Link/Rx Loss Port1 0: NO 1: YES
1.3.6.1.4.1.4756.20.502.20.1.140ColumnnidPort4LLFLogicPort2RemoteBread-writecurrentNID Series card Port4 link loss forwarding - Link/Rx Loss Port2 0: NO 1: YES
1.3.6.1.4.1.4756.20.502.20.1.141ColumnnidPort4LLFLogicPort3RemoteBread-writecurrentNID Series card Port4 link loss forwarding - Link/Rx Loss Port3 0: NO 1: YES
1.3.6.1.4.1.4756.20.502.20.1.142ColumnnidPort4LLFLogicPort5RemoteBread-writecurrentNID Series card Port4 link loss forwarding - Link/Rx Loss Port5 0: NO 1: YES
1.3.6.1.4.1.4756.20.502.20.1.143ColumnnidPort4LLFLogicPort6RemoteBread-writecurrentNID Series card Port4 link loss forwarding - Link/Rx Loss Port6 0: NO 1: YES
1.3.6.1.4.1.4756.20.502.20.1.144ColumnnidPort4LLFLogicPort7RemoteBread-writecurrentNID Series card Port4 link loss forwarding - Link/Rx Loss Port7 0: NO 1: YES
1.3.6.1.4.1.4756.20.502.20.1.145ColumnnidPort4LLFLogicPort8RemoteBread-writecurrentNID Series card Port4 link loss forwarding - Link/Rx Loss Port8 0: NO 1: YES
1.3.6.1.4.1.4756.20.502.20.1.146ColumnnidPort5LLFLogicRemoteBread-writecurrentNID Series card Port5 link loss forwarding - Logic 0: AND 1: OR
1.3.6.1.4.1.4756.20.502.20.1.147ColumnnidPort5LLFLogicPort1RemoteBread-writecurrentNID Series card Port5 link loss forwarding - Link/Rx Loss Port1 0: NO 1: YES
1.3.6.1.4.1.4756.20.502.20.1.148ColumnnidPort5LLFLogicPort2RemoteBread-writecurrentNID Series card Port5 link loss forwarding - Link/Rx Loss Port2 0: NO 1: YES
1.3.6.1.4.1.4756.20.502.20.1.149ColumnnidPort5LLFLogicPort3RemoteBread-writecurrentNID Series card Port5 link loss forwarding - Link/Rx Loss Port3 0: NO 1: YES
1.3.6.1.4.1.4756.20.502.20.1.150ColumnnidPort5LLFLogicPort4RemoteBread-writecurrentNID Series card Port5 link loss forwarding - Link/Rx Loss Port4 0: NO 1: YES
1.3.6.1.4.1.4756.20.502.20.1.151ColumnnidPort5LLFLogicPort6RemoteBread-writecurrentNID Series card Port5 link loss forwarding - Link/Rx Loss Port6 0: NO 1: YES
1.3.6.1.4.1.4756.20.502.20.1.152ColumnnidPort5LLFLogicPort7RemoteBread-writecurrentNID Series card Port5 link loss forwarding - Link/Rx Loss Port7 0: NO 1: YES
1.3.6.1.4.1.4756.20.502.20.1.153ColumnnidPort5LLFLogicPort8RemoteBread-writecurrentNID Series card Port5 link loss forwarding - Link/Rx Loss Port8 0: NO 1: YES
1.3.6.1.4.1.4756.20.502.20.1.154ColumnnidPort6LLFLogicRemoteBread-writecurrentNID Series card Port6 link loss forwarding - Logic 0: AND 1: OR
1.3.6.1.4.1.4756.20.502.20.1.155ColumnnidPort6LLFLogicPort1RemoteBread-writecurrentNID Series card Port6 link loss forwarding - Link/Rx Loss Port1 0: NO 1: YES
1.3.6.1.4.1.4756.20.502.20.1.156ColumnnidPort6LLFLogicPort2RemoteBread-writecurrentNID Series card Port6 link loss forwarding - Link/Rx Loss Port2 0: NO 1: YES
1.3.6.1.4.1.4756.20.502.20.1.157ColumnnidPort6LLFLogicPort3RemoteBread-writecurrentNID Series card Port6 link loss forwarding - Link/Rx Loss Port3 0: NO 1: YES
1.3.6.1.4.1.4756.20.502.20.1.158ColumnnidPort6LLFLogicPort4RemoteBread-writecurrentNID Series card Port6 link loss forwarding - Link/Rx Loss Port4 0: NO 1: YES
1.3.6.1.4.1.4756.20.502.20.1.159ColumnnidPort6LLFLogicPort5RemoteBread-writecurrentNID Series card Port6 link loss forwarding - Link/Rx Loss Port5 0: NO 1: YES
1.3.6.1.4.1.4756.20.502.20.1.160ColumnnidPort6LLFLogicPort7RemoteBread-writecurrentNID Series card Port4 link loss forwarding - Link/Rx Loss Port7 0: NO 1: YES
1.3.6.1.4.1.4756.20.502.20.1.161ColumnnidPort6LLFLogicPort8RemoteBread-writecurrentNID Series card Port6 link loss forwarding - Link/Rx Loss Port8 0: NO 1: YES
1.3.6.1.4.1.4756.20.502.20.1.162ColumnnidPort7LLFLogicRemoteBread-writecurrentNID Series card Port7 link loss forwarding - Logic 0: AND 1: OR
1.3.6.1.4.1.4756.20.502.20.1.163ColumnnidPort7LLFLogicPort1RemoteBread-writecurrentNID Series card Port7 link loss forwarding - Link/Rx Loss Port1 0: NO 1: YES
1.3.6.1.4.1.4756.20.502.20.1.164ColumnnidPort7LLFLogicPort2RemoteBread-writecurrentNID Series card Port7 link loss forwarding - Link/Rx Loss Port2 0: NO 1: YES
1.3.6.1.4.1.4756.20.502.20.1.165ColumnnidPort7LLFLogicPort3RemoteBread-writecurrentNID Series card Port7 link loss forwarding - Link/Rx Loss Port3 0: NO 1: YES
1.3.6.1.4.1.4756.20.502.20.1.166ColumnnidPort7LLFLogicPort4RemoteBread-writecurrentNID Series card Port7 link loss forwarding - Link/Rx Loss Port4 0: NO 1: YES
1.3.6.1.4.1.4756.20.502.20.1.167ColumnnidPort7LLFLogicPort5RemoteBread-writecurrentNID Series card Port7 link loss forwarding - Link/Rx Loss Port5 0: NO 1: YES
1.3.6.1.4.1.4756.20.502.20.1.168ColumnnidPort7LLFLogicPort6RemoteBread-writecurrentNID Series card Port4 link loss forwarding - Link/Rx Loss Port6 0: NO 1: YES
1.3.6.1.4.1.4756.20.502.20.1.169ColumnnidPort7LLFLogicPort8RemoteBread-writecurrentNID Series card Port7 link loss forwarding - Link/Rx Loss Port8 0: NO 1: YES
1.3.6.1.4.1.4756.20.502.20.1.170ColumnnidPort8LLFLogicRemoteBread-writecurrentNID Series card Port8 link loss forwarding - Logic 0: AND 1: OR
1.3.6.1.4.1.4756.20.502.20.1.171ColumnnidPort8LLFLogicPort1RemoteBread-writecurrentNID Series card Port8 link loss forwarding - Link/Rx Loss Port1 0: NO 1: YES
1.3.6.1.4.1.4756.20.502.20.1.172ColumnnidPort8LLFLogicPort2RemoteBread-writecurrentNID Series card Port8 link loss forwarding - Link/Rx Loss Port2 0: NO 1: YES
1.3.6.1.4.1.4756.20.502.20.1.173ColumnnidPort8LLFLogicPort3RemoteBread-writecurrentNID Series card Port5 link loss forwarding - Link/Rx Loss Port3 0: NO 1: YES
1.3.6.1.4.1.4756.20.502.20.1.174ColumnnidPort8LLFLogicPort4RemoteBread-writecurrentNID Series card Port8 link loss forwarding - Link/Rx Loss Port4 0: NO 1: YES
1.3.6.1.4.1.4756.20.502.20.1.175ColumnnidPort8LLFLogicPort5RemoteBread-writecurrentNID Series card Port8 link loss forwarding - Link/Rx Loss Port5 0: NO 1: YES
1.3.6.1.4.1.4756.20.502.20.1.176ColumnnidPort8LLFLogicPort6RemoteBread-writecurrentNID Series card Port8 link loss forwarding - Link/Rx Loss Port6 0: NO 1: YES
1.3.6.1.4.1.4756.20.502.20.1.177ColumnnidPort8LLFLogicPort7RemoteBread-writecurrentNID Series card Port8 link loss forwarding - Link/Rx Loss Port7 0: NO 1: YES
1.3.6.1.4.1.4756.20.502.20.1.178ColumnnidPort1PacketsRxRemoteBread-onlycurrentNID Series card port1 traffic overview:: Packets Rx
1.3.6.1.4.1.4756.20.502.20.1.179ColumnnidPort1PacketsTxRemoteBread-onlycurrentNID Series card port1 traffic overview:: Packets Tx
1.3.6.1.4.1.4756.20.502.20.1.180ColumnnidPort1BytesRxRemoteBread-onlycurrentNID Series card port1 traffic overview:: Bytes Rx
1.3.6.1.4.1.4756.20.502.20.1.181ColumnnidPort1BytesTxRemoteBread-onlycurrentNID Series card port1 traffic overview:: Bytes Tx
1.3.6.1.4.1.4756.20.502.20.1.182ColumnnidPort1ErrorsRxRemoteBread-onlycurrentNID Series card port1 traffic overview:: Errors Rx
1.3.6.1.4.1.4756.20.502.20.1.183ColumnnidPort1ErrorsTxRemoteBread-onlycurrentNID Series card port1 traffic overview:: Errors Tx
1.3.6.1.4.1.4756.20.502.20.1.184ColumnnidPort1DropsRxRemoteBread-onlycurrentNID Series card port1 traffic overview:: Drops Rx
1.3.6.1.4.1.4756.20.502.20.1.185ColumnnidPort1DropsTxRemoteBread-onlycurrentNID Series card port1 traffic overview:: Drops Tx
1.3.6.1.4.1.4756.20.502.20.1.186ColumnnidPort1FilteredRxRemoteBread-onlycurrentNID Series card port1 traffic overview:: Filtered Rx
1.3.6.1.4.1.4756.20.502.20.1.187ColumnnidPort2PacketsRxRemoteBread-onlycurrentNID Series card port2 traffic overview:: Packets Rx
1.3.6.1.4.1.4756.20.502.20.1.188ColumnnidPort2PacketsTxRemoteBread-onlycurrentNID Series card port2 traffic overview:: Packets Tx
1.3.6.1.4.1.4756.20.502.20.1.189ColumnnidPort2BytesRxRemoteBread-onlycurrentNID Series card port2 traffic overview:: Bytes Rx
1.3.6.1.4.1.4756.20.502.20.1.190ColumnnidPort2BytesTxRemoteBread-onlycurrentNID Series card port2 traffic overview:: Bytes Tx
1.3.6.1.4.1.4756.20.502.20.1.191ColumnnidPort2ErrorsRxRemoteBread-onlycurrentNID Series card port2 traffic overview:: Errors Rx
1.3.6.1.4.1.4756.20.502.20.1.192ColumnnidPort2ErrorsTxRemoteBread-onlycurrentNID Series card port2 traffic overview:: Errors Tx
1.3.6.1.4.1.4756.20.502.20.1.193ColumnnidPort2DropsRxRemoteBread-onlycurrentNID Series card port2 traffic overview:: Drops Rx
1.3.6.1.4.1.4756.20.502.20.1.194ColumnnidPort2DropsTxRemoteBread-onlycurrentNID Series card port2 traffic overview:: Drops Tx
1.3.6.1.4.1.4756.20.502.20.1.195ColumnnidPort2FilteredRxRemoteBread-onlycurrentNID Series card port2 traffic overview:: Filtered Rx
1.3.6.1.4.1.4756.20.502.20.1.196ColumnnidPort3PacketsRxRemoteBread-onlycurrentNID Series card port3 traffic overview:: Packets Rx
1.3.6.1.4.1.4756.20.502.20.1.197ColumnnidPort3PacketsTxRemoteBread-onlycurrentNID Series card port3 traffic overview:: Packets Tx
1.3.6.1.4.1.4756.20.502.20.1.198ColumnnidPort3BytesRxRemoteBread-onlycurrentNID Series card port3 traffic overview:: Bytes Rx
1.3.6.1.4.1.4756.20.502.20.1.199ColumnnidPort3BytesTxRemoteBread-onlycurrentNID Series card port3 traffic overview:: Bytes Tx
1.3.6.1.4.1.4756.20.502.20.1.200ColumnnidPort3ErrorsRxRemoteBread-onlycurrentNID Series card port3 traffic overview:: Errors Rx
1.3.6.1.4.1.4756.20.502.20.1.201ColumnnidPort3ErrorsTxRemoteBread-onlycurrentNID Series card port3 traffic overview:: Errors Tx
1.3.6.1.4.1.4756.20.502.20.1.202ColumnnidPort3DropsRxRemoteBread-onlycurrentNID Series card port3 traffic overview:: Drops Rx
1.3.6.1.4.1.4756.20.502.20.1.203ColumnnidPort3DropsTxRemoteBread-onlycurrentNID Series card port3 traffic overview:: Drops Tx
1.3.6.1.4.1.4756.20.502.20.1.204ColumnnidPort3FilteredRxRemoteBread-onlycurrentNID Series card port3 traffic overview:: Filtered Rx
1.3.6.1.4.1.4756.20.502.20.1.205ColumnnidPort4PacketsRxRemoteBread-onlycurrentNID Series card port4 traffic overview:: Packets Rx
1.3.6.1.4.1.4756.20.502.20.1.206ColumnnidPort4PacketsTxRemoteBread-onlycurrentNID Series card port4 traffic overview:: Packets Tx
1.3.6.1.4.1.4756.20.502.20.1.207ColumnnidPort4BytesRxRemoteBread-onlycurrentNID Series card port4 traffic overview:: Bytes Rx
1.3.6.1.4.1.4756.20.502.20.1.208ColumnnidPort4BytesTxRemoteBread-onlycurrentNID Series card port4 traffic overview:: Bytes Tx
1.3.6.1.4.1.4756.20.502.20.1.209ColumnnidPort4ErrorsRxRemoteBread-onlycurrentNID Series card port4 traffic overview:: Errors Rx
1.3.6.1.4.1.4756.20.502.20.1.210ColumnnidPort4ErrorsTxRemoteBread-onlycurrentNID Series card port4 traffic overview:: Errors Tx
1.3.6.1.4.1.4756.20.502.20.1.211ColumnnidPort4DropsRxRemoteBread-onlycurrentNID Series card port4 traffic overview:: Drops Rx
1.3.6.1.4.1.4756.20.502.20.1.212ColumnnidPort4DropsTxRemoteBread-onlycurrentNID Series card port4 traffic overview:: Drops Tx
1.3.6.1.4.1.4756.20.502.20.1.213ColumnnidPort4FilteredRxRemoteBread-onlycurrentNID Series card port4 traffic overview:: Filtered Rx
1.3.6.1.4.1.4756.20.502.20.1.214ColumnnidPort5PacketsRxRemoteBread-onlycurrentNID Series card port5 traffic overview:: Packets Rx
1.3.6.1.4.1.4756.20.502.20.1.215ColumnnidPort5PacketsTxRemoteBread-onlycurrentNID Series card port5 traffic overview:: Packets Tx
1.3.6.1.4.1.4756.20.502.20.1.216ColumnnidPort5BytesRxRemoteBread-onlycurrentNID Series card port5 traffic overview:: Bytes Rx
1.3.6.1.4.1.4756.20.502.20.1.217ColumnnidPort5BytesTxRemoteBread-onlycurrentNID Series card port5 traffic overview:: Bytes Tx
1.3.6.1.4.1.4756.20.502.20.1.218ColumnnidPort5ErrorsRxRemoteBread-onlycurrentNID Series card port5 traffic overview:: Errors Rx
1.3.6.1.4.1.4756.20.502.20.1.219ColumnnidPort5ErrorsTxRemoteBread-onlycurrentNID Series card port5 traffic overview:: Errors Tx
1.3.6.1.4.1.4756.20.502.20.1.220ColumnnidPort5DropsRxRemoteBread-onlycurrentNID Series card port5 traffic overview:: Drops Rx
1.3.6.1.4.1.4756.20.502.20.1.221ColumnnidPort5DropsTxRemoteBread-onlycurrentNID Series card port5 traffic overview:: Drops Tx
1.3.6.1.4.1.4756.20.502.20.1.222ColumnnidPort5FilteredRxRemoteBread-onlycurrentNID Series card port5 traffic overview:: Filtered Rx
1.3.6.1.4.1.4756.20.502.20.1.223ColumnnidPort6PacketsRxRemoteBread-onlycurrentNID Series card port6 traffic overview:: Packets Rx
1.3.6.1.4.1.4756.20.502.20.1.224ColumnnidPort6PacketsTxRemoteBread-onlycurrentNID Series card port6 traffic overview:: Packets Tx
1.3.6.1.4.1.4756.20.502.20.1.225ColumnnidPort6BytesRxRemoteBread-onlycurrentNID Series card port6 traffic overview:: Bytes Rx
1.3.6.1.4.1.4756.20.502.20.1.226ColumnnidPort6BytesTxRemoteBread-onlycurrentNID Series card port6 traffic overview:: Bytes Tx
1.3.6.1.4.1.4756.20.502.20.1.227ColumnnidPort6ErrorsRxRemoteBread-onlycurrentNID Series card port6 traffic overview:: Errors Rx
1.3.6.1.4.1.4756.20.502.20.1.228ColumnnidPort6ErrorsTxRemoteBread-onlycurrentNID Series card port6 traffic overview:: Errors Tx
1.3.6.1.4.1.4756.20.502.20.1.229ColumnnidPort6DropsRxRemoteBread-onlycurrentNID Series card port6 traffic overview:: Drops Rx
1.3.6.1.4.1.4756.20.502.20.1.230ColumnnidPort6DropsTxRemoteBread-onlycurrentNID Series card port6 traffic overview:: Drops Tx
1.3.6.1.4.1.4756.20.502.20.1.231ColumnnidPort6FilteredRxRemoteBread-onlycurrentNID Series card port6 traffic overview:: Filtered Rx
1.3.6.1.4.1.4756.20.502.20.1.232ColumnnidPort7PacketsRxRemoteBread-onlycurrentNID Series card port7 traffic overview:: Packets Rx
1.3.6.1.4.1.4756.20.502.20.1.233ColumnnidPort7PacketsTxRemoteBread-onlycurrentNID Series card port7 traffic overview:: Packets Tx
1.3.6.1.4.1.4756.20.502.20.1.234ColumnnidPort7BytesRxRemoteBread-onlycurrentNID Series card port7 traffic overview:: Bytes Rx
1.3.6.1.4.1.4756.20.502.20.1.235ColumnnidPort7BytesTxRemoteBread-onlycurrentNID Series card port7 traffic overview:: Bytes Tx
1.3.6.1.4.1.4756.20.502.20.1.236ColumnnidPort7ErrorsRxRemoteBread-onlycurrentNID Series card port7 traffic overview:: Errors Rx
1.3.6.1.4.1.4756.20.502.20.1.237ColumnnidPort7ErrorsTxRemoteBread-onlycurrentNID Series card port7 traffic overview:: Errors Tx
1.3.6.1.4.1.4756.20.502.20.1.238ColumnnidPort7DropsRxRemoteBread-onlycurrentNID Series card port7 traffic overview:: Drops Rx
1.3.6.1.4.1.4756.20.502.20.1.239ColumnnidPort7DropsTxRemoteBread-onlycurrentNID Series card port7 traffic overview:: Drops Tx
1.3.6.1.4.1.4756.20.502.20.1.240ColumnnidPort7FilteredRxRemoteBread-onlycurrentNID Series card port7 traffic overview:: Filtered Rx
1.3.6.1.4.1.4756.20.502.20.1.241ColumnnidPort8PacketsRxRemoteBread-onlycurrentNID Series card port8 traffic overview:: Packets Rx
1.3.6.1.4.1.4756.20.502.20.1.242ColumnnidPort8PacketsTxRemoteBread-onlycurrentNID Series card port8 traffic overview:: Packets Tx
1.3.6.1.4.1.4756.20.502.20.1.243ColumnnidPort8BytesRxRemoteBread-onlycurrentNID Series card port8 traffic overview:: Bytes Rx
1.3.6.1.4.1.4756.20.502.20.1.244ColumnnidPort8BytesTxRemoteBread-onlycurrentNID Series card port8 traffic overview:: Bytes Tx
1.3.6.1.4.1.4756.20.502.20.1.245ColumnnidPort8ErrorsRxRemoteBread-onlycurrentNID Series card port8 traffic overview:: Errors Rx
1.3.6.1.4.1.4756.20.502.20.1.246ColumnnidPort8ErrorsTxRemoteBread-onlycurrentNID Series card port8 traffic overview:: Errors Tx
1.3.6.1.4.1.4756.20.502.20.1.247ColumnnidPort8DropsRxRemoteBread-onlycurrentNID Series card port8 traffic overview:: Drops Rx
1.3.6.1.4.1.4756.20.502.20.1.248ColumnnidPort8DropsTxRemoteBread-onlycurrentNID Series card port8 traffic overview:: Drops Tx
1.3.6.1.4.1.4756.20.502.20.1.249ColumnnidPort8FilteredRxRemoteBread-onlycurrentNID Series card port8 traffic overview:: Filtered Rx
1.3.6.1.4.1.4756.20.502.20.1.250ColumnnidAggrSourceMACAddrRemoteBread-writecurrentNID Series card Aggregation Mode Configuration: Source MAC Address 0: No 1: Yes
1.3.6.1.4.1.4756.20.502.20.1.251ColumnnidAggrDestinationMACAddrRemoteBread-writecurrentNID Series card Aggregation Mode Configuration: Destination MAC Address 0: No 1: Yes
1.3.6.1.4.1.4756.20.502.20.1.252ColumnnidAggrIPAddrRemoteBread-writecurrentNID Series card Aggregation Mode Configuration: IP Address 0: No 1: Yes
1.3.6.1.4.1.4756.20.502.20.1.253ColumnnidAggrTCPUDPPortNumRemoteBread-writecurrentNID Series card Aggregation Mode Configuration: TCP/UDP Port Number 0: No 1: Yes
1.3.6.1.4.1.4756.20.502.20.1.254ColumnnidAggrGroupPort1ConfRemoteBread-writecurrentNID Series card Aggregation Group Port1 Configuration: 0: Normal 1: ID1 2: ID2 3: ID3 4: ID4
1.3.6.1.4.1.4756.20.502.20.1.255ColumnnidAggrGroupPort2ConfRemoteBread-writecurrentNID Series card Aggregation Group Port2 Configuration: 0: Normal 1: ID1 2: ID2 3: ID3 4: ID4
1.3.6.1.4.1.4756.20.502.20.1.256ColumnnidAggrGroupPort3ConfRemoteBread-writecurrentNID Series card Aggregation Group Port3 Configuration: 0: Normal 1: ID1 2: ID2 3: ID3 4: ID4
1.3.6.1.4.1.4756.20.502.20.1.257ColumnnidAggrGroupPort4ConfRemoteBread-writecurrentNID Series card Aggregation Group Port4 Configuration: 0: Normal 1: ID1 2: ID2 3: ID3 4: ID4
1.3.6.1.4.1.4756.20.502.20.1.258ColumnnidAggrGroupPort5ConfRemoteBread-writecurrentNID Series card Aggregation Group Port5 Configuration: 0: Normal 1: ID1 2: ID2 3: ID3 4: ID4
1.3.6.1.4.1.4756.20.502.20.1.259ColumnnidAggrGroupPort6ConfRemoteBread-writecurrentNID Series card Aggregation Group Port6 Configuration: 0: Normal 1: ID1 2: ID2 3: ID3 4: ID4
1.3.6.1.4.1.4756.20.502.20.1.260ColumnnidAggrGroupPort7ConfRemoteBread-writecurrentNID Series card Aggregation Group Port7 Configuration: 0: Normal 1: ID1 2: ID2 3: ID3 4: ID4
1.3.6.1.4.1.4756.20.502.20.1.261ColumnnidAggrGroupPort8ConfRemoteBread-writecurrentNID Series card Aggregation Group Port8 Configuration: 0: Normal 1: ID1 2: ID2 3: ID3 4: ID4
1.3.6.1.4.1.4756.20.502.20.1.262ColumnnidPort1LACPEnabledRemoteBread-writecurrentNID Series card Port1 LACP Enabled: 0: No 1: Yes
1.3.6.1.4.1.4756.20.502.20.1.263ColumnnidPort1LACPKEYRemoteBread-writecurrentNID Series card Port1 LACP Key value: The Key value incurred by the port, range 0-65535.The value of 0 means auto.
1.3.6.1.4.1.4756.20.502.20.1.264ColumnnidPort1LACPRoleRemoteBread-writecurrentNID Series card Port1 LACP Role: 0: Passive 1: Active
1.3.6.1.4.1.4756.20.502.20.1.265ColumnnidPort1LACPTimeOutRemoteBread-writecurrentNID Series card Port1 LACP Time out: 0: Slow 1: Fast
1.3.6.1.4.1.4756.20.502.20.1.266ColumnnidPort1LACPPrioRemoteBread-writecurrentNID Series card Port1 LACP priority: The Key value incurred by the port, range 1-65535.
1.3.6.1.4.1.4756.20.502.20.1.267ColumnnidPort2LACPEnabledRemoteBread-writecurrentNID Series card Port2 LACP Enabled: 0: No 1: Yes
1.3.6.1.4.1.4756.20.502.20.1.268ColumnnidPort2LACPKEYRemoteBread-writecurrentNID Series card Port2 LACP Key value: The Key value incurred by the port, range 0-65535.The value of 0 means auto.
1.3.6.1.4.1.4756.20.502.20.1.269ColumnnidPort2LACPRoleRemoteBread-writecurrentNID Series card Port2 LACP Role: 0: Passive 1: Active
1.3.6.1.4.1.4756.20.502.20.1.270ColumnnidPort2LACPTimeOutRemoteBread-writecurrentNID Series card Port2 LACP Time out: 0: Slow 1: Fast
1.3.6.1.4.1.4756.20.502.20.1.271ColumnnidPort2LACPPrioRemoteBread-writecurrentNID Series card Port2 LACP priority: The Key value incurred by the port, range 1-65535.
1.3.6.1.4.1.4756.20.502.20.1.272ColumnnidPort3LACPEnabledRemoteBread-writecurrentNID Series card Port3 LACP Enabled: 0: No 1: Yes
1.3.6.1.4.1.4756.20.502.20.1.273ColumnnidPort3LACPKEYRemoteBread-writecurrentNID Series card Port3 LACP Key value: The Key value incurred by the port, range 0-65535.The value of 0 means auto.
1.3.6.1.4.1.4756.20.502.20.1.274ColumnnidPort3LACPRoleRemoteBread-writecurrentNID Series card Port3 LACP Role: 0: Passive 1: Active
1.3.6.1.4.1.4756.20.502.20.1.275ColumnnidPort3LACPTimeOutRemoteBread-writecurrentNID Series card Port3 LACP Time out: 0: Slow 1: Fast
1.3.6.1.4.1.4756.20.502.20.1.276ColumnnidPort3LACPPrioRemoteBread-writecurrentNID Series card Port3 LACP priority: The Key value incurred by the port, range 1-65535.
1.3.6.1.4.1.4756.20.502.20.1.277ColumnnidPort4LACPEnabledRemoteBread-writecurrentNID Series card Port4 LACP Enabled: 0: No 1: Yes
1.3.6.1.4.1.4756.20.502.20.1.278ColumnnidPort4LACPKEYRemoteBread-writecurrentNID Series card Port4 LACP Key value: The Key value incurred by the port, range 0-65535.The value of 0 means auto.
1.3.6.1.4.1.4756.20.502.20.1.279ColumnnidPort4LACPRoleRemoteBread-writecurrentNID Series card Port4 LACP Role: 0: Passive 1: Active
1.3.6.1.4.1.4756.20.502.20.1.280ColumnnidPort4LACPTimeOutRemoteBread-writecurrentNID Series card Port4 LACP Time out: 0: Slow 1: Fast
1.3.6.1.4.1.4756.20.502.20.1.281ColumnnidPort4LACPPrioRemoteBread-writecurrentNID Series card Port4 LACP priority: The Key value incurred by the port, range 1-65535.
1.3.6.1.4.1.4756.20.502.20.1.282ColumnnidPort5LACPEnabledRemoteBread-writecurrentNID Series card Port5 LACP Enabled: 0: No 1: Yes
1.3.6.1.4.1.4756.20.502.20.1.283ColumnnidPort5LACPKEYRemoteBread-writecurrentNID Series card Port5 LACP Key value: The Key value incurred by the port, range 0-65535.The value of 0 means auto.
1.3.6.1.4.1.4756.20.502.20.1.284ColumnnidPort5LACPRoleRemoteBread-writecurrentNID Series card Port5 LACP Role: 0: Passive 1: Active
1.3.6.1.4.1.4756.20.502.20.1.285ColumnnidPort5LACPTimeOutRemoteBread-writecurrentNID Series card Port5 LACP Time out: 0: Slow 1: Fast
1.3.6.1.4.1.4756.20.502.20.1.286ColumnnidPort5LACPPrioRemoteBread-writecurrentNID Series card Port5 LACP priority: The Key value incurred by the port, range 1-65535.
1.3.6.1.4.1.4756.20.502.20.1.287ColumnnidPort6LACPEnabledRemoteBread-writecurrentNID Series card Port6 LACP Enabled: 0: No 1: Yes
1.3.6.1.4.1.4756.20.502.20.1.288ColumnnidPort6LACPKEYRemoteBread-writecurrentNID Series card Port6 LACP Key value: The Key value incurred by the port, range 0-65535.The value of 0 means auto.
1.3.6.1.4.1.4756.20.502.20.1.289ColumnnidPort6LACPRoleRemoteBread-writecurrentNID Series card Port6 LACP Role: 0: Passive 1: Active
1.3.6.1.4.1.4756.20.502.20.1.290ColumnnidPort6LACPTimeOutRemoteBread-writecurrentNID Series card Port6 LACP Time out: 0: Slow 1: Fast
1.3.6.1.4.1.4756.20.502.20.1.291ColumnnidPort6LACPPrioRemoteBread-writecurrentNID Series card Port6 LACP priority: The Key value incurred by the port, range 1-65535.
1.3.6.1.4.1.4756.20.502.20.1.292ColumnnidPort7LACPEnabledRemoteBread-writecurrentNID Series card Port7 LACP Enabled: 0: No 1: Yes
1.3.6.1.4.1.4756.20.502.20.1.293ColumnnidPort7LACPKEYRemoteBread-writecurrentNID Series card Port7 LACP Key value: The Key value incurred by the port, range 0-65535.The value of 0 means auto.
1.3.6.1.4.1.4756.20.502.20.1.294ColumnnidPort7LACPRoleRemoteBread-writecurrentNID Series card Port7 LACP Role: 0: Passive 1: Active
1.3.6.1.4.1.4756.20.502.20.1.295ColumnnidPort7LACPTimeOutRemoteBread-writecurrentNID Series card Port7 LACP Time out: 0: Slow 1: Fast
1.3.6.1.4.1.4756.20.502.20.1.296ColumnnidPort7LACPPrioRemoteBread-writecurrentNID Series card Port7 LACP priority: The Key value incurred by the port, range 1-65535.
1.3.6.1.4.1.4756.20.502.20.1.297ColumnnidPort8LACPEnabledRemoteBread-writecurrentNID Series card Port8 LACP Enabled: 0: No 1: Yes
1.3.6.1.4.1.4756.20.502.20.1.298ColumnnidPort8LACPKEYRemoteBread-writecurrentNID Series card Port8 LACP Key value: The Key value incurred by the port, range 0-65535.The value of 0 means auto.
1.3.6.1.4.1.4756.20.502.20.1.299ColumnnidPort8LACPRoleRemoteBread-writecurrentNID Series card Port8 LACP Role: 0: Passive 1: Active
1.3.6.1.4.1.4756.20.502.20.1.300ColumnnidPort8LACPTimeOutRemoteBread-writecurrentNID Series card Port8 LACP Time out: 0: Slow 1: Fast
1.3.6.1.4.1.4756.20.502.20.1.301ColumnnidPort8LACPPrioRemoteBread-writecurrentNID Series card Port8 LACP priority: The Key value incurred by the port, range 1-65535.
1.3.6.1.4.1.4756.20.502.20.1.302ColumnnidPort1LACPstsRemoteBread-onlycurrentNID Series card Port1 LACP status: 0: No 1: Yes 2: Standby
1.3.6.1.4.1.4756.20.502.20.1.303ColumnnidPort1LACPKEYstsRemoteBread-onlycurrentNID Series card Port1 LACP status: Key
1.3.6.1.4.1.4756.20.502.20.1.304ColumnnidPort1LACPAggrIDstsRemoteBread-onlycurrentNID Series card Port1 LACP status: Aggr ID
1.3.6.1.4.1.4756.20.502.20.1.305ColumnnidPort1LACPParnterSysIDstsRemoteBread-onlycurrentNID Series card Port1 LACP status: Parnter System ID
1.3.6.1.4.1.4756.20.502.20.1.306ColumnnidPort1LACPParnterPortstsRemoteBread-onlycurrentNID Series card Port1 LACP status: Parnter Port Status
1.3.6.1.4.1.4756.20.502.20.1.307ColumnnidPort1LACPParnterProistsRemoteBread-onlycurrentNID Series card Port1 LACP status: Parnter Priority
1.3.6.1.4.1.4756.20.502.20.1.308ColumnnidPort2LACPstsRemoteBread-onlycurrentNID Series card Port2 LACP status: 0: No 1: Yes 2: Standby
1.3.6.1.4.1.4756.20.502.20.1.309ColumnnidPort2LACPKEYstsRemoteBread-onlycurrentNID Series card Port2 LACP status: Key
1.3.6.1.4.1.4756.20.502.20.1.310ColumnnidPort2LACPAggrIDstsRemoteBread-onlycurrentNID Series card Port2 LACP status: Aggr ID
1.3.6.1.4.1.4756.20.502.20.1.311ColumnnidPort2LACPParnterSysIDstsRemoteBread-onlycurrentNID Series card Port2 LACP status: Parnter System ID
1.3.6.1.4.1.4756.20.502.20.1.312ColumnnidPort2LACPParnterPortstsRemoteBread-onlycurrentNID Series card Port2 LACP status: Parnter Port Status
1.3.6.1.4.1.4756.20.502.20.1.313ColumnnidPort2LACPParnterProistsRemoteBread-onlycurrentNID Series card Port2 LACP status: Parnter Priority
1.3.6.1.4.1.4756.20.502.20.1.314ColumnnidPort3LACPstsRemoteBread-onlycurrentNID Series card Port3 LACP status: 0: No 1: Yes 2: Standby
1.3.6.1.4.1.4756.20.502.20.1.315ColumnnidPort3LACPKEYstsRemoteBread-onlycurrentNID Series card Port3 LACP status: Key
1.3.6.1.4.1.4756.20.502.20.1.316ColumnnidPort3LACPAggrIDstsRemoteBread-onlycurrentNID Series card Port3 LACP status: Aggr ID
1.3.6.1.4.1.4756.20.502.20.1.317ColumnnidPort3LACPParnterSysIDstsRemoteBread-onlycurrentNID Series card Port3 LACP status: Parnter System ID
1.3.6.1.4.1.4756.20.502.20.1.318ColumnnidPort3LACPParnterPortstsRemoteBread-onlycurrentNID Series card Port3 LACP status: Parnter Port Status
1.3.6.1.4.1.4756.20.502.20.1.319ColumnnidPort3LACPParnterProistsRemoteBread-onlycurrentNID Series card Port3 LACP status: Parnter Priority
1.3.6.1.4.1.4756.20.502.20.1.320ColumnnidPort4LACPstsRemoteBread-onlycurrentNID Series card Port4 LACP status: 0: No 1: Yes 2: Standby
1.3.6.1.4.1.4756.20.502.20.1.321ColumnnidPort4LACPKEYstsRemoteBread-onlycurrentNID Series card Port4 LACP status: Key
1.3.6.1.4.1.4756.20.502.20.1.322ColumnnidPort4LACPAggrIDstsRemoteBread-onlycurrentNID Series card Port4 LACP status: Aggr ID
1.3.6.1.4.1.4756.20.502.20.1.323ColumnnidPort4LACPParnterSysIDstsRemoteBread-onlycurrentNID Series card Port4 LACP status: Parnter System ID
1.3.6.1.4.1.4756.20.502.20.1.324ColumnnidPort4LACPParnterPortstsRemoteBread-onlycurrentNID Series card Port4 LACP status: Parnter Port Status
1.3.6.1.4.1.4756.20.502.20.1.325ColumnnidPort4LACPParnterProistsRemoteBread-onlycurrentNID Series card Port4 LACP status: Parnter Priority
1.3.6.1.4.1.4756.20.502.20.1.326ColumnnidPort5LACPstsRemoteBread-onlycurrentNID Series card Port5 LACP status: 0: No 1: Yes 2: Standby
1.3.6.1.4.1.4756.20.502.20.1.327ColumnnidPort5LACPKEYstsRemoteBread-onlycurrentNID Series card Port5 LACP status: Key
1.3.6.1.4.1.4756.20.502.20.1.328ColumnnidPort5LACPAggrIDstsRemoteBread-onlycurrentNID Series card Port5 LACP status: Aggr ID
1.3.6.1.4.1.4756.20.502.20.1.329ColumnnidPort5LACPParnterSysIDstsRemoteBread-onlycurrentNID Series card Port5 LACP status: Parnter System ID
1.3.6.1.4.1.4756.20.502.20.1.330ColumnnidPort5LACPParnterPortstsRemoteBread-onlycurrentNID Series card Port5 LACP status: Parnter Port Status
1.3.6.1.4.1.4756.20.502.20.1.331ColumnnidPort5LACPParnterProistsRemoteBread-onlycurrentNID Series card Port5 LACP status: Parnter Priority
1.3.6.1.4.1.4756.20.502.20.1.332ColumnnidPort6LACPstsRemoteBread-onlycurrentNID Series card Port6 LACP status: 0: No 1: Yes 2: Standby
1.3.6.1.4.1.4756.20.502.20.1.333ColumnnidPort6LACPKEYstsRemoteBread-onlycurrentNID Series card Port6 LACP status: Key
1.3.6.1.4.1.4756.20.502.20.1.334ColumnnidPort6LACPAggrIDstsRemoteBread-onlycurrentNID Series card Port6 LACP status: Aggr ID
1.3.6.1.4.1.4756.20.502.20.1.335ColumnnidPort6LACPParnterSysIDstsRemoteBread-onlycurrentNID Series card Port6 LACP status: Parnter System ID
1.3.6.1.4.1.4756.20.502.20.1.336ColumnnidPort6LACPParnterPortstsRemoteBread-onlycurrentNID Series card Port6 LACP status: Parnter Port Status
1.3.6.1.4.1.4756.20.502.20.1.337ColumnnidPort6LACPParnterProistsRemoteBread-onlycurrentNID Series card Port6 LACP status: Parnter Priority
1.3.6.1.4.1.4756.20.502.20.1.338ColumnnidPort7LACPstsRemoteBread-onlycurrentNID Series card Port7 LACP status: 0: No 1: Yes 2: Standby
1.3.6.1.4.1.4756.20.502.20.1.339ColumnnidPort7LACPKEYstsRemoteBread-onlycurrentNID Series card Port7 LACP status: Key
1.3.6.1.4.1.4756.20.502.20.1.340ColumnnidPort7LACPAggrIDstsRemoteBread-onlycurrentNID Series card Port7 LACP status: Aggr ID
1.3.6.1.4.1.4756.20.502.20.1.341ColumnnidPort7LACPParnterSysIDstsRemoteBread-onlycurrentNID Series card Port7 LACP status: Parnter System ID
1.3.6.1.4.1.4756.20.502.20.1.342ColumnnidPort7LACPParnterPortstsRemoteBread-onlycurrentNID Series card Port7 LACP status: Parnter Port Status
1.3.6.1.4.1.4756.20.502.20.1.343ColumnnidPort7LACPParnterProistsRemoteBread-onlycurrentNID Series card Port7 LACP status: Parnter Priority
1.3.6.1.4.1.4756.20.502.20.1.344ColumnnidPort8LACPstsRemoteBread-onlycurrentNID Series card Port8 LACP status: 0: No 1: Yes 2: Standby
1.3.6.1.4.1.4756.20.502.20.1.345ColumnnidPort8LACPKEYstsRemoteBread-onlycurrentNID Series card Port8 LACP status: Key
1.3.6.1.4.1.4756.20.502.20.1.346ColumnnidPort8LACPAggrIDstsRemoteBread-onlycurrentNID Series card Port8 LACP status: Aggr ID
1.3.6.1.4.1.4756.20.502.20.1.347ColumnnidPort8LACPParnterSysIDstsRemoteBread-onlycurrentNID Series card Port8 LACP status: Parnter System ID
1.3.6.1.4.1.4756.20.502.20.1.348ColumnnidPort8LACPParnterPortstsRemoteBread-onlycurrentNID Series card Port8 LACP status: Parnter Port Status
1.3.6.1.4.1.4756.20.502.20.1.349ColumnnidPort8LACPParnterProistsRemoteBread-onlycurrentNID Series card Port8 LACP status: Parnter Priority
1.3.6.1.4.1.4756.20.502.20.1.350ColumnnidOAMPort1EnableRemoteBread-writecurrentNID Series card Port1 OAM: 0: Off 1: On
1.3.6.1.4.1.4756.20.502.20.1.351ColumnnidOAMPort1ModeRemoteBread-writecurrentNID Series card Port1 OAM: 0: Passive 1: Active
1.3.6.1.4.1.4756.20.502.20.1.352ColumnnidOAMPort1LoopBackRemoteBread-writecurrentNID Series card Port1 OAM LoopBack: 0: Off 1: On
1.3.6.1.4.1.4756.20.502.20.1.353ColumnnidOAMPort1LinkMonitorRemoteBread-writecurrentNID Series card Port1 OAM Link Monitor: 0: Off 1: On
1.3.6.1.4.1.4756.20.502.20.1.354ColumnnidOAMPort1MIBRetrievalRemoteBread-writecurrentNID Series card Port1 OAM MIB Retrieval: 0: Off 1: On
1.3.6.1.4.1.4756.20.502.20.1.355ColumnnidOAMPort1LoopBackOPRemoteBread-writecurrentNID Series card Port1 OAM LoopBack operation: 0: Off 1: On
1.3.6.1.4.1.4756.20.502.20.1.356ColumnnidOAMPort2EnableRemoteBread-writecurrentNID Series card Port2 OAM: 0: Off 1: On
1.3.6.1.4.1.4756.20.502.20.1.357ColumnnidOAMPort2ModeRemoteBread-writecurrentNID Series card Port2 OAM: 0: Passive 1: Active
1.3.6.1.4.1.4756.20.502.20.1.358ColumnnidOAMPort2LoopBackRemoteBread-writecurrentNID Series card Port2 OAM LoopBack: 0: Off 1: On
1.3.6.1.4.1.4756.20.502.20.1.359ColumnnidOAMPort2LinkMonitorRemoteBread-writecurrentNID Series card Port2 OAM Link Monitor: 0: Off 1: On
1.3.6.1.4.1.4756.20.502.20.1.360ColumnnidOAMPort2MIBRetrievalRemoteBread-writecurrentNID Series card Port2 OAM MIB Retrieval: 0: Off 1: On
1.3.6.1.4.1.4756.20.502.20.1.361ColumnnidOAMPort2LoopBackOPRemoteBread-writecurrentNID Series card Port2 OAM LoopBack operation: 0: Off 1: On
1.3.6.1.4.1.4756.20.502.20.1.362ColumnnidOAMPort3EnableRemoteBread-writecurrentNID Series card Port3 OAM: 0: Off 1: On
1.3.6.1.4.1.4756.20.502.20.1.363ColumnnidOAMPort3ModeRemoteBread-writecurrentNID Series card Port3 OAM: 0: Passive 1: Active
1.3.6.1.4.1.4756.20.502.20.1.364ColumnnidOAMPort3LoopBackRemoteBread-writecurrentNID Series card Port3 OAM: 0: Off 1: On
1.3.6.1.4.1.4756.20.502.20.1.365ColumnnidOAMPort3LinkMonitorRemoteBread-writecurrentNID Series card Port3 OAM Link Monitor: 0: Off 1: On
1.3.6.1.4.1.4756.20.502.20.1.366ColumnnidOAMPort3MIBRetrievalRemoteBread-writecurrentNID Series card Port3 OAM MIB Retrieval: 0: Off 1: On
1.3.6.1.4.1.4756.20.502.20.1.367ColumnnidOAMPort3LoopBackOPRemoteBread-writecurrentNID Series card Port3 OAM LoopBack operation: 0: Disable 1: Enable
1.3.6.1.4.1.4756.20.502.20.1.368ColumnnidOAMPort4EnableRemoteBread-writecurrentNID Series card Port4 OAM: 0: Off 1: On
1.3.6.1.4.1.4756.20.502.20.1.369ColumnnidOAMPort4ModeRemoteBread-writecurrentNID Series card Port4 OAM: 0: Passive 1: Active
1.3.6.1.4.1.4756.20.502.20.1.370ColumnnidOAMPort4LoopBackRemoteBread-writecurrentNID Series card Port4 OAM: 0: Off 1: On
1.3.6.1.4.1.4756.20.502.20.1.371ColumnnidOAMPort4LinkMonitorRemoteBread-writecurrentNID Series card Port4 OAM Link Monitor: 0: Off 1: On
1.3.6.1.4.1.4756.20.502.20.1.372ColumnnidOAMPort4MIBRetrievalRemoteBread-writecurrentNID Series card Port4 OAM MIB Retrieval: 0: Off 1: On
1.3.6.1.4.1.4756.20.502.20.1.373ColumnnidOAMPort4LoopBackOPRemoteBread-writecurrentNID Series card Port4 OAM LoopBack operation: 0: On 1: Off
1.3.6.1.4.1.4756.20.502.20.1.374ColumnnidOAMPort5EnableRemoteBread-writecurrentNID Series card Port5 OAM: 0: Off 1: On
1.3.6.1.4.1.4756.20.502.20.1.375ColumnnidOAMPort5ModeRemoteBread-writecurrentNID Series card Port5 OAM: 0: Passive 1: Active
1.3.6.1.4.1.4756.20.502.20.1.376ColumnnidOAMPort5LoopBackRemoteBread-writecurrentNID Series card Port5 OAM: 0: Off 1: On
1.3.6.1.4.1.4756.20.502.20.1.377ColumnnidOAMPort5LinkMonitorRemoteBread-writecurrentNID Series card Port5 OAM Link Monitor: 0: Off 1: On
1.3.6.1.4.1.4756.20.502.20.1.378ColumnnidOAMPort5MIBRetrievalRemoteBread-writecurrentNID Series card Port5 OAM MIB Retrieval: 0: Off 1: On
1.3.6.1.4.1.4756.20.502.20.1.379ColumnnidOAMPort5LoopBackOPRemoteBread-writecurrentNID Series card Port5 OAM LoopBack operation: 0: On 1: Off
1.3.6.1.4.1.4756.20.502.20.1.380ColumnnidOAMPort6EnableRemoteBread-writecurrentNID Series card Port6 OAM: 0: Off 1: On
1.3.6.1.4.1.4756.20.502.20.1.381ColumnnidOAMPort6ModeRemoteBread-writecurrentNID Series card Port6 OAM: 0: Passive 1: Active
1.3.6.1.4.1.4756.20.502.20.1.382ColumnnidOAMPort6LoopBackRemoteBread-writecurrentNID Series card Port6 OAM: 0: Off 1: On
1.3.6.1.4.1.4756.20.502.20.1.383ColumnnidOAMPort6LinkMonitorRemoteBread-writecurrentNID Series card Port6 OAM Link Monitor: 0: Off 1: On
1.3.6.1.4.1.4756.20.502.20.1.384ColumnnidOAMPort6MIBRetrievalRemoteBread-writecurrentNID Series card Port6 OAM MIB Retrieval: 0: Off 1: On
1.3.6.1.4.1.4756.20.502.20.1.385ColumnnidOAMPort6LoopBackOPRemoteBread-writecurrentNID Series card Port6 OAM LoopBack operation: 0: On 1: Off
1.3.6.1.4.1.4756.20.502.20.1.386ColumnnidOAMPort7EnableRemoteBread-writecurrentNID Series card Port7 OAM: 0: Off 1: On
1.3.6.1.4.1.4756.20.502.20.1.387ColumnnidOAMPort7ModeRemoteBread-writecurrentNID Series card Port7 OAM: 0: Passive 1: Active
1.3.6.1.4.1.4756.20.502.20.1.388ColumnnidOAMPort7LoopBackRemoteBread-writecurrentNID Series card Port7 OAM: 0: Off 1: On
1.3.6.1.4.1.4756.20.502.20.1.389ColumnnidOAMPort7LinkMonitorRemoteBread-writecurrentNID Series card Port7 OAM Link Monitor: 0: Off 1: On
1.3.6.1.4.1.4756.20.502.20.1.390ColumnnidOAMPort7MIBRetrievalRemoteBread-writecurrentNID Series card Port7 OAM MIB Retrieval: 0: Off 1: On
1.3.6.1.4.1.4756.20.502.20.1.391ColumnnidOAMPort7LoopBackOPRemoteBread-writecurrentNID Series card Port7 OAM LoopBack operation: 0: On 1: Off
1.3.6.1.4.1.4756.20.502.20.1.392ColumnnidOAMPort8EnableRemoteBread-writecurrentNID Series card Port8 OAM: 0: Off 1: On
1.3.6.1.4.1.4756.20.502.20.1.393ColumnnidOAMPort8ModeRemoteBread-writecurrentNID Series card Port8 OAM: 0: Passive 1: Active
1.3.6.1.4.1.4756.20.502.20.1.394ColumnnidOAMPort8LoopBackRemoteBread-writecurrentNID Series card Port8 OAM: 0: Off 1: On
1.3.6.1.4.1.4756.20.502.20.1.395ColumnnidOAMPort8LinkMonitorRemoteBread-writecurrentNID Series card Port8 OAM Link Monitor: 0: Off 1: On
1.3.6.1.4.1.4756.20.502.20.1.396ColumnnidOAMPort8MIBRetrievalRemoteBread-writecurrentNID Series card Port8 OAM MIB Retrieval: 0: Off 1: On
1.3.6.1.4.1.4756.20.502.20.1.397ColumnnidOAMPort8LoopBackOPRemoteBread-writecurrentNID Series card Port8 OAM LoopBack operation: 0: On 1: Off
1.3.6.1.4.1.4756.20.502.20.1.398ColumnnidPort1EFEErrorWindowRemoteBread-writecurrentNID Series card Port1 Link Event Configuration: Error Frame Event - Error Window
1.3.6.1.4.1.4756.20.502.20.1.399ColumnnidPort1EFEErrorThresholdRemoteBread-writecurrentNID Series card Port1 Link Event Configuration: Error Frame Event - Error Threshold
1.3.6.1.4.1.4756.20.502.20.1.400ColumnnidPort1SPEEErrorWindowRemoteBread-writecurrentNID Series card Port1 Link Event Configuration: Symbol Period Error Event - Error Window
1.3.6.1.4.1.4756.20.502.20.1.401ColumnnidPort1SPEEErrorThresholdRemoteBread-writecurrentNID Series card Port1 Link Event Configuration: Symbol Period Error Event - Error Threshold
1.3.6.1.4.1.4756.20.502.20.1.402ColumnnidPort1SSEErrorWindowRemoteBread-writecurrentNID Series card Port1 Link Event Configuration: Seconds Summary Event - Error Window
1.3.6.1.4.1.4756.20.502.20.1.403ColumnnidPort1SSEErrorThresholdRemoteBread-writecurrentNID Series card Port1 Link Event Configuration: Seconds Summary Event - Error Threshold
1.3.6.1.4.1.4756.20.502.20.1.404ColumnnidPort2EFEErrorWindowRemoteBread-writecurrentNID Series card Port2 Link Event Configuration: Error Frame Event - Error Window
1.3.6.1.4.1.4756.20.502.20.1.405ColumnnidPort2EFEErrorThresholdRemoteBread-writecurrentNID Series card Port2 Link Event Configuration: Error Frame Event - Error Threshold
1.3.6.1.4.1.4756.20.502.20.1.406ColumnnidPort2SPEEErrorWindowRemoteBread-writecurrentNID Series card Port2 Link Event Configuration: Symbol Period Error Event - Error Window
1.3.6.1.4.1.4756.20.502.20.1.407ColumnnidPort2SPEEErrorThresholdRemoteBread-writecurrentNID Series card Port2 Link Event Configuration: Symbol Period Error Event - Error Threshold
1.3.6.1.4.1.4756.20.502.20.1.408ColumnnidPort2SSEErrorWindowRemoteBread-writecurrentNID Series card Port2 Link Event Configuration: Seconds Summary Event - Error Window
1.3.6.1.4.1.4756.20.502.20.1.409ColumnnidPort2SSEErrorThresholdRemoteBread-writecurrentNID Series card Port2 Link Event Configuration: Seconds Summary Event - Error Threshold
1.3.6.1.4.1.4756.20.502.20.1.410ColumnnidPort3EFEErrorWindowRemoteBread-writecurrentNID Series card Port3 Link Event Configuration: Error Frame Event - Error Window
1.3.6.1.4.1.4756.20.502.20.1.411ColumnnidPort3EFEErrorThresholdRemoteBread-writecurrentNID Series card Port3 Link Event Configuration: Error Frame Event - Error Threshold
1.3.6.1.4.1.4756.20.502.20.1.412ColumnnidPort3SPEEErrorWindowRemoteBread-writecurrentNID Series card Port3 Link Event Configuration: Symbol Period Error Event - Error Window
1.3.6.1.4.1.4756.20.502.20.1.413ColumnnidPort3SPEEErrorThresholdRemoteBread-writecurrentNID Series card Port3 Link Event Configuration: Symbol Period Error Event - Error Threshold
1.3.6.1.4.1.4756.20.502.20.1.414ColumnnidPort3SSEErrorWindowRemoteBread-writecurrentNID Series card Port3 Link Event Configuration: Seconds Summary Event - Error Window
1.3.6.1.4.1.4756.20.502.20.1.415ColumnnidPort3SSEErrorThresholdRemoteBread-writecurrentNID Series card Port3 Link Event Configuration: Seconds Summary Event - Error Threshold
1.3.6.1.4.1.4756.20.502.20.1.416ColumnnidPort4EFEErrorWindowRemoteBread-writecurrentNID Series card Port4 Link Event Configuration: Error Frame Event - Error Window
1.3.6.1.4.1.4756.20.502.20.1.417ColumnnidPort4EFEErrorThresholdRemoteBread-writecurrentNID Series card Port4 Link Event Configuration: Error Frame Event - Error Threshold
1.3.6.1.4.1.4756.20.502.20.1.418ColumnnidPort4SPEEErrorWindowRemoteBread-writecurrentNID Series card Port4 Link Event Configuration: Symbol Period Error Event - Error Window
1.3.6.1.4.1.4756.20.502.20.1.419ColumnnidPort4SPEEErrorThresholdRemoteBread-writecurrentNID Series card Port4 Link Event Configuration: Symbol Period Error Event - Error Threshold
1.3.6.1.4.1.4756.20.502.20.1.420ColumnnidPort4SSEErrorWindowRemoteBread-writecurrentNID Series card Port4 Link Event Configuration: Seconds Summary Event - Error Window
1.3.6.1.4.1.4756.20.502.20.1.421ColumnnidPort4SSEErrorThresholdRemoteBread-writecurrentNID Series card Port4 Link Event Configuration: Seconds Summary Event - Error Threshold
1.3.6.1.4.1.4756.20.502.20.1.422ColumnnidPort5EFEErrorWindowRemoteBread-writecurrentNID Series card Port5 Link Event Configuration: Error Frame Event - Error Window
1.3.6.1.4.1.4756.20.502.20.1.423ColumnnidPort5EFEErrorThresholdRemoteBread-writecurrentNID Series card Port5 Link Event Configuration: Error Frame Event - Error Threshold
1.3.6.1.4.1.4756.20.502.20.1.424ColumnnidPort5SPEEErrorWindowRemoteBread-writecurrentNID Series card Port5 Link Event Configuration: Symbol Period Error Event - Error Window
1.3.6.1.4.1.4756.20.502.20.1.425ColumnnidPort5SPEEErrorThresholdRemoteBread-writecurrentNID Series card Port5 Link Event Configuration: Symbol Period Error Event - Error Threshold
1.3.6.1.4.1.4756.20.502.20.1.426ColumnnidPort5SSEErrorWindowRemoteBread-writecurrentNID Series card Port5 Link Event Configuration: Seconds Summary Event - Error Window
1.3.6.1.4.1.4756.20.502.20.1.427ColumnnidPort5SSEErrorThresholdRemoteBread-writecurrentNID Series card Port5 Link Event Configuration: Seconds Summary Event - Error Threshold
1.3.6.1.4.1.4756.20.502.20.1.428ColumnnidPort6EFEErrorWindowRemoteBread-writecurrentNID Series card Port6 Link Event Configuration: Error Frame Event - Error Window
1.3.6.1.4.1.4756.20.502.20.1.429ColumnnidPort6EFEErrorThresholdRemoteBread-writecurrentNID Series card Port6 Link Event Configuration: Error Frame Event - Error Threshold
1.3.6.1.4.1.4756.20.502.20.1.430ColumnnidPort6SPEEErrorWindowRemoteBread-writecurrentNID Series card Port6 Link Event Configuration: Symbol Period Error Event - Error Window
1.3.6.1.4.1.4756.20.502.20.1.431ColumnnidPort6SPEEErrorThresholdRemoteBread-writecurrentNID Series card Port6 Link Event Configuration: Symbol Period Error Event - Error Threshold
1.3.6.1.4.1.4756.20.502.20.1.432ColumnnidPort6SSEErrorWindowRemoteBread-writecurrentNID Series card Port6 Link Event Configuration: Seconds Summary Event - Error Window
1.3.6.1.4.1.4756.20.502.20.1.433ColumnnidPort6SSEErrorThresholdRemoteBread-writecurrentNID Series card Port6 Link Event Configuration: Seconds Summary Event - Error Threshold
1.3.6.1.4.1.4756.20.502.20.1.434ColumnnidPort7EFEErrorWindowRemoteBread-writecurrentNID Series card Port7 Link Event Configuration: Error Frame Event - Error Window
1.3.6.1.4.1.4756.20.502.20.1.435ColumnnidPort7EFEErrorThresholdRemoteBread-writecurrentNID Series card Port7 Link Event Configuration: Error Frame Event - Error Threshold
1.3.6.1.4.1.4756.20.502.20.1.436ColumnnidPort7SPEEErrorWindowRemoteBread-writecurrentNID Series card Port7 Link Event Configuration: Symbol Period Error Event - Error Window
1.3.6.1.4.1.4756.20.502.20.1.437ColumnnidPort7SPEEErrorThresholdRemoteBread-writecurrentNID Series card Port7 Link Event Configuration: Symbol Period Error Event - Error Threshold
1.3.6.1.4.1.4756.20.502.20.1.438ColumnnidPort7SSEErrorWindowRemoteBread-writecurrentNID Series card Port7 Link Event Configuration: Seconds Summary Event - Error Window
1.3.6.1.4.1.4756.20.502.20.1.439ColumnnidPort7SSEErrorThresholdRemoteBread-writecurrentNID Series card Port7 Link Event Configuration: Seconds Summary Event - Error Threshold
1.3.6.1.4.1.4756.20.502.20.1.440ColumnnidPort8EFEErrorWindowRemoteBread-writecurrentNID Series card Port8 Link Event Configuration: Error Frame Event - Error Window
1.3.6.1.4.1.4756.20.502.20.1.441ColumnnidPort8EFEErrorThresholdRemoteBread-writecurrentNID Series card Port8 Link Event Configuration: Error Frame Event - Error Threshold
1.3.6.1.4.1.4756.20.502.20.1.442ColumnnidPort8SPEEErrorWindowRemoteBread-writecurrentNID Series card Port8 Link Event Configuration: Symbol Period Error Event - Error Window
1.3.6.1.4.1.4756.20.502.20.1.443ColumnnidPort8SPEEErrorThresholdRemoteBread-writecurrentNID Series card Port8 Link Event Configuration: Symbol Period Error Event - Error Threshold
1.3.6.1.4.1.4756.20.502.20.1.444ColumnnidPort8SSEErrorWindowRemoteBread-writecurrentNID Series card Port8 Link Event Configuration: Seconds Summary Event - Error Window
1.3.6.1.4.1.4756.20.502.20.1.445ColumnnidPort8SSEErrorThresholdRemoteBread-writecurrentNID Series card Port8 Link Event Configuration: Seconds Summary Event - Error Threshold
1.3.6.1.4.1.4756.20.502.20.1.446ColumnnidPort1RxOAMInfoPDURemoteBread-onlycurrentNID Series card Port1 Detailed Link OAM Statistics: Rx OAM Information PDU's
1.3.6.1.4.1.4756.20.502.20.1.447ColumnnidPort1RxUniqueErrorEventRemoteBread-onlycurrentNID Series card Port1 Detailed Link OAM Statistics: Rx Unique Error Event Notificatio
1.3.6.1.4.1.4756.20.502.20.1.448ColumnnidPort1RxDuplicateErrorEventRemoteBread-onlycurrentNID Series card Port1 Detailed Link OAM Statistics: Rx Duplicate Error Event Notification
1.3.6.1.4.1.4756.20.502.20.1.449ColumnnidPort1RxLoopBackControlRemoteBread-onlycurrentNID Series card Port1 Detailed Link OAM Statistics: Rx Loopback Control
1.3.6.1.4.1.4756.20.502.20.1.450ColumnnidPort1RxVariableRequestRemoteBread-onlycurrentNID Series card Port1 Detailed Link OAM Statistics: Rx Variable Request
1.3.6.1.4.1.4756.20.502.20.1.451ColumnnidPort1RxVariableResponseRemoteBread-onlycurrentNID Series card Port1 Detailed Link OAM Statistics: Rx Variable Response
1.3.6.1.4.1.4756.20.502.20.1.452ColumnnidPort1RxOrgSpecificPDURemoteBread-onlycurrentNID Series card Port1 Detailed Link OAM Statistics: Rx Org Specific PDU's
1.3.6.1.4.1.4756.20.502.20.1.453ColumnnidPort1RxUnsupportedCodesRemoteBread-onlycurrentNID Series card Port1 Detailed Link OAM Statistics: Rx Unsupported Codes
1.3.6.1.4.1.4756.20.502.20.1.454ColumnnidPort1RxLinkFaultPDURemoteBread-onlycurrentNID Series card Port1 Detailed Link OAM Statistics: Rx Link Fault PDU's
1.3.6.1.4.1.4756.20.502.20.1.455ColumnnidPort1RxDyingGaspRemoteBread-onlycurrentNID Series card Port1 Detailed Link OAM Statistics: Rx Dying Gasp
1.3.6.1.4.1.4756.20.502.20.1.456ColumnnidPort1RxCriticalEventPDURemoteBread-onlycurrentNID Series card Port1 Detailed Link OAM Statistics: Rx Dying Gasp
1.3.6.1.4.1.4756.20.502.20.1.457ColumnnidPort1TxOAMInfoPDURemoteBread-onlycurrentNID Series card Port1 Detailed Link OAM Statistics: Tx OAM Information PDU's
1.3.6.1.4.1.4756.20.502.20.1.458ColumnnidPort1TxUniqueErrorEventRemoteBread-onlycurrentNID Series card Port1 Detailed Link OAM Statistics: Tx Unique Error Event Notificatio
1.3.6.1.4.1.4756.20.502.20.1.459ColumnnidPort1TxDuplicateErrorEventRemoteBread-onlycurrentNID Series card Port1 Detailed Link OAM Statistics: Tx Duplicate Error Event Notification
1.3.6.1.4.1.4756.20.502.20.1.460ColumnnidPort1TxLoopBackControlRemoteBread-onlycurrentNID Series card Port1 Detailed Link OAM Statistics: Tx Loopback Control
1.3.6.1.4.1.4756.20.502.20.1.461ColumnnidPort1TxVariableRequestRemoteBread-onlycurrentNID Series card Port1 Detailed Link OAM Statistics: Tx Variable Request
1.3.6.1.4.1.4756.20.502.20.1.462ColumnnidPort1TxVariableResponseRemoteBread-onlycurrentNID Series card Port1 Detailed Link OAM Statistics: Tx Variable Response
1.3.6.1.4.1.4756.20.502.20.1.463ColumnnidPort1TxOrgSpecificPDURemoteBread-onlycurrentNID Series card Port1 Detailed Link OAM Statistics: Tx Org Specific PDU's
1.3.6.1.4.1.4756.20.502.20.1.464ColumnnidPort1TxUnsupportedCodesRemoteBread-onlycurrentNID Series card Port1 Detailed Link OAM Statistics: Tx Unsupported Codes
1.3.6.1.4.1.4756.20.502.20.1.465ColumnnidPort1TxLinkFaultPDURemoteBread-onlycurrentNID Series card Port1 Detailed Link OAM Statistics: Tx Link Fault PDU's
1.3.6.1.4.1.4756.20.502.20.1.466ColumnnidPort1TxDyingGaspRemoteBread-onlycurrentNID Series card Port1 Detailed Link OAM Statistics: Tx Dying Gasp
1.3.6.1.4.1.4756.20.502.20.1.467ColumnnidPort1TxCriticalEventPDURemoteBread-onlycurrentNID Series card Port1 Detailed Link OAM Statistics: Tx Dying Gasp
1.3.6.1.4.1.4756.20.502.20.1.468ColumnnidPort2RxOAMInfoPDURemoteBread-onlycurrentNID Series card Port2 Detailed Link OAM Statistics: Rx OAM Information PDU's
1.3.6.1.4.1.4756.20.502.20.1.469ColumnnidPort2RxUniqueErrorEventRemoteBread-onlycurrentNID Series card Port2 Detailed Link OAM Statistics: Rx Unique Error Event Notificatio
1.3.6.1.4.1.4756.20.502.20.1.470ColumnnidPort2RxDuplicateErrorEventRemoteBread-onlycurrentNID Series card Port2 Detailed Link OAM Statistics: Rx Duplicate Error Event Notification
1.3.6.1.4.1.4756.20.502.20.1.471ColumnnidPort2RxLoopBackControlRemoteBread-onlycurrentNID Series card Port2 Detailed Link OAM Statistics: Rx Loopback Control
1.3.6.1.4.1.4756.20.502.20.1.472ColumnnidPort2RxVariableRequestRemoteBread-onlycurrentNID Series card Port2 Detailed Link OAM Statistics: Rx Variable Request
1.3.6.1.4.1.4756.20.502.20.1.473ColumnnidPort2RxVariableResponseRemoteBread-onlycurrentNID Series card Port2 Detailed Link OAM Statistics: Rx Variable Response
1.3.6.1.4.1.4756.20.502.20.1.474ColumnnidPort2RxOrgSpecificPDURemoteBread-onlycurrentNID Series card Port2 Detailed Link OAM Statistics: Rx Org Specific PDU's
1.3.6.1.4.1.4756.20.502.20.1.475ColumnnidPort2RxUnsupportedCodesRemoteBread-onlycurrentNID Series card Port2 Detailed Link OAM Statistics: Rx Unsupported Codes
1.3.6.1.4.1.4756.20.502.20.1.476ColumnnidPort2RxLinkFaultPDURemoteBread-onlycurrentNID Series card Port2 Detailed Link OAM Statistics: Rx Link Fault PDU's
1.3.6.1.4.1.4756.20.502.20.1.477ColumnnidPort2RxDyingGaspRemoteBread-onlycurrentNID Series card Port2 Detailed Link OAM Statistics: Rx Dying Gasp
1.3.6.1.4.1.4756.20.502.20.1.478ColumnnidPort2RxCriticalEventPDURemoteBread-onlycurrentNID Series card Port2 Detailed Link OAM Statistics: Rx Dying Gasp
1.3.6.1.4.1.4756.20.502.20.1.479ColumnnidPort2TxOAMInfoPDURemoteBread-onlycurrentNID Series card Port2 Detailed Link OAM Statistics: Tx OAM Information PDU's
1.3.6.1.4.1.4756.20.502.20.1.480ColumnnidPort2TxUniqueErrorEventRemoteBread-onlycurrentNID Series card Port2 Detailed Link OAM Statistics: Tx Unique Error Event Notificatio
1.3.6.1.4.1.4756.20.502.20.1.481ColumnnidPort2TxDuplicateErrorEventRemoteBread-onlycurrentNID Series card Port2 Detailed Link OAM Statistics: Tx Duplicate Error Event Notification
1.3.6.1.4.1.4756.20.502.20.1.482ColumnnidPort2TxLoopBackControlRemoteBread-onlycurrentNID Series card Port2 Detailed Link OAM Statistics: Tx Loopback Control
1.3.6.1.4.1.4756.20.502.20.1.483ColumnnidPort2TxVariableRequestRemoteBread-onlycurrentNID Series card Port2 Detailed Link OAM Statistics: Tx Variable Request
1.3.6.1.4.1.4756.20.502.20.1.484ColumnnidPort2TxVariableResponseRemoteBread-onlycurrentNID Series card Port2 Detailed Link OAM Statistics: Tx Variable Response
1.3.6.1.4.1.4756.20.502.20.1.485ColumnnidPort2TxOrgSpecificPDURemoteBread-onlycurrentNID Series card Port2 Detailed Link OAM Statistics: Tx Org Specific PDU's
1.3.6.1.4.1.4756.20.502.20.1.486ColumnnidPort2TxUnsupportedCodesRemoteBread-onlycurrentNID Series card Port2 Detailed Link OAM Statistics: Tx Unsupported Codes
1.3.6.1.4.1.4756.20.502.20.1.487ColumnnidPort2TxLinkFaultPDURemoteBread-onlycurrentNID Series card Port2 Detailed Link OAM Statistics: Tx Link Fault PDU's
1.3.6.1.4.1.4756.20.502.20.1.488ColumnnidPort2TxDyingGaspRemoteBread-onlycurrentNID Series card Port2 Detailed Link OAM Statistics: Tx Dying Gasp
1.3.6.1.4.1.4756.20.502.20.1.489ColumnnidPort2TxCriticalEventPDURemoteBread-onlycurrentNID Series card Port2 Detailed Link OAM Statistics: Tx Dying Gasp
1.3.6.1.4.1.4756.20.502.20.1.490ColumnnidPort3RxOAMInfoPDURemoteBread-onlycurrentNID Series card Port3 Detailed Link OAM Statistics: Rx OAM Information PDU's
1.3.6.1.4.1.4756.20.502.20.1.491ColumnnidPort3RxUniqueErrorEventRemoteBread-onlycurrentNID Series card Port3 Detailed Link OAM Statistics: Rx Unique Error Event Notificatio
1.3.6.1.4.1.4756.20.502.20.1.492ColumnnidPort3RxDuplicateErrorEventRemoteBread-onlycurrentNID Series card Port3 Detailed Link OAM Statistics: Rx Duplicate Error Event Notification
1.3.6.1.4.1.4756.20.502.20.1.493ColumnnidPort3RxLoopBackControlRemoteBread-onlycurrentNID Series card Port3 Detailed Link OAM Statistics: Rx Loopback Control
1.3.6.1.4.1.4756.20.502.20.1.494ColumnnidPort3RxVariableRequestRemoteBread-onlycurrentNID Series card Port3 Detailed Link OAM Statistics: Rx Variable Request
1.3.6.1.4.1.4756.20.502.20.1.495ColumnnidPort3RxVariableResponseRemoteBread-onlycurrentNID Series card Port3 Detailed Link OAM Statistics: Rx Variable Response
1.3.6.1.4.1.4756.20.502.20.1.496ColumnnidPort3RxOrgSpecificPDURemoteBread-onlycurrentNID Series card Port3 Detailed Link OAM Statistics: Rx Org Specific PDU's
1.3.6.1.4.1.4756.20.502.20.1.497ColumnnidPort3RxUnsupportedCodesRemoteBread-onlycurrentNID Series card Port3 Detailed Link OAM Statistics: Rx Unsupported Codes
1.3.6.1.4.1.4756.20.502.20.1.498ColumnnidPort3RxLinkFaultPDURemoteBread-onlycurrentNID Series card Port3 Detailed Link OAM Statistics: Rx Link Fault PDU's
1.3.6.1.4.1.4756.20.502.20.1.499ColumnnidPort3RxDyingGaspRemoteBread-onlycurrentNID Series card Port3 Detailed Link OAM Statistics: Rx Dying Gasp
1.3.6.1.4.1.4756.20.502.20.1.500ColumnnidPort3RxCriticalEventPDURemoteBread-onlycurrentNID Series card Port3 Detailed Link OAM Statistics: Rx Dying Gasp
1.3.6.1.4.1.4756.20.502.20.1.501ColumnnidPort3TxOAMInfoPDURemoteBread-onlycurrentNID Series card Port3 Detailed Link OAM Statistics: Tx OAM Information PDU's
1.3.6.1.4.1.4756.20.502.20.1.502ColumnnidPort3TxUniqueErrorEventRemoteBread-onlycurrentNID Series card Port3 Detailed Link OAM Statistics: Tx Unique Error Event Notificatio
1.3.6.1.4.1.4756.20.502.20.1.503ColumnnidPort3TxDuplicateErrorEventRemoteBread-onlycurrentNID Series card Port3 Detailed Link OAM Statistics: Tx Duplicate Error Event Notification
1.3.6.1.4.1.4756.20.502.20.1.504ColumnnidPort3TxLoopBackControlRemoteBread-onlycurrentNID Series card Port3 Detailed Link OAM Statistics: Tx Loopback Control
1.3.6.1.4.1.4756.20.502.20.1.505ColumnnidPort3TxVariableRequestRemoteBread-onlycurrentNID Series card Port3 Detailed Link OAM Statistics: Tx Variable Request
1.3.6.1.4.1.4756.20.502.20.1.506ColumnnidPort3TxVariableResponseRemoteBread-onlycurrentNID Series card Port3 Detailed Link OAM Statistics: Tx Variable Response
1.3.6.1.4.1.4756.20.502.20.1.507ColumnnidPort3TxOrgSpecificPDURemoteBread-onlycurrentNID Series card Port3 Detailed Link OAM Statistics: Tx Org Specific PDU's
1.3.6.1.4.1.4756.20.502.20.1.508ColumnnidPort3TxUnsupportedCodesRemoteBread-onlycurrentNID Series card Port3 Detailed Link OAM Statistics: Tx Unsupported Codes
1.3.6.1.4.1.4756.20.502.20.1.509ColumnnidPort3TxLinkFaultPDURemoteBread-onlycurrentNID Series card Port3 Detailed Link OAM Statistics: Tx Link Fault PDU's
1.3.6.1.4.1.4756.20.502.20.1.510ColumnnidPort3TxDyingGaspRemoteBread-onlycurrentNID Series card Port3 Detailed Link OAM Statistics: Tx Dying Gasp
1.3.6.1.4.1.4756.20.502.20.1.511ColumnnidPort3TxCriticalEventPDURemoteBread-onlycurrentNID Series card Port3 Detailed Link OAM Statistics: Tx Dying Gasp
1.3.6.1.4.1.4756.20.502.20.1.512ColumnnidPort4RxOAMInfoPDURemoteBread-onlycurrentNID Series card Port4 Detailed Link OAM Statistics: Rx OAM Information PDU's
1.3.6.1.4.1.4756.20.502.20.1.513ColumnnidPort4RxUniqueErrorEventRemoteBread-onlycurrentNID Series card Port4 Detailed Link OAM Statistics: Rx Unique Error Event Notificatio
1.3.6.1.4.1.4756.20.502.20.1.514ColumnnidPort4RxDuplicateErrorEventRemoteBread-onlycurrentNID Series card Port4 Detailed Link OAM Statistics: Rx Duplicate Error Event Notification
1.3.6.1.4.1.4756.20.502.20.1.515ColumnnidPort4RxLoopBackControlRemoteBread-onlycurrentNID Series card Port4 Detailed Link OAM Statistics: Rx Loopback Control
1.3.6.1.4.1.4756.20.502.20.1.516ColumnnidPort4RxVariableRequestRemoteBread-onlycurrentNID Series card Port4 Detailed Link OAM Statistics: Rx Variable Request
1.3.6.1.4.1.4756.20.502.20.1.517ColumnnidPort4RxVariableResponseRemoteBread-onlycurrentNID Series card Port4 Detailed Link OAM Statistics: Rx Variable Response
1.3.6.1.4.1.4756.20.502.20.1.518ColumnnidPort4RxOrgSpecificPDURemoteBread-onlycurrentNID Series card Port4 Detailed Link OAM Statistics: Rx Org Specific PDU's
1.3.6.1.4.1.4756.20.502.20.1.519ColumnnidPort4RxUnsupportedCodesRemoteBread-onlycurrentNID Series card Port4 Detailed Link OAM Statistics: Rx Unsupported Codes
1.3.6.1.4.1.4756.20.502.20.1.520ColumnnidPort4RxLinkFaultPDURemoteBread-onlycurrentNID Series card Port4 Detailed Link OAM Statistics: Rx Link Fault PDU's
1.3.6.1.4.1.4756.20.502.20.1.521ColumnnidPort4RxDyingGaspRemoteBread-onlycurrentNID Series card Port4 Detailed Link OAM Statistics: Rx Dying Gasp
1.3.6.1.4.1.4756.20.502.20.1.522ColumnnidPort4RxCriticalEventPDURemoteBread-onlycurrentNID Series card Port4 Detailed Link OAM Statistics: Rx Dying Gasp
1.3.6.1.4.1.4756.20.502.20.1.523ColumnnidPort4TxOAMInfoPDURemoteBread-onlycurrentNID Series card Port4 Detailed Link OAM Statistics: Tx OAM Information PDU's
1.3.6.1.4.1.4756.20.502.20.1.524ColumnnidPort4TxUniqueErrorEventRemoteBread-onlycurrentNID Series card Port4 Detailed Link OAM Statistics: Tx Unique Error Event Notificatio
1.3.6.1.4.1.4756.20.502.20.1.525ColumnnidPort4TxDuplicateErrorEventRemoteBread-onlycurrentNID Series card Port4 Detailed Link OAM Statistics: Tx Duplicate Error Event Notification
1.3.6.1.4.1.4756.20.502.20.1.526ColumnnidPort4TxLoopBackControlRemoteBread-onlycurrentNID Series card Port4 Detailed Link OAM Statistics: Tx Loopback Control
1.3.6.1.4.1.4756.20.502.20.1.527ColumnnidPort4TxVariableRequestRemoteBread-onlycurrentNID Series card Port4 Detailed Link OAM Statistics: Tx Variable Request
1.3.6.1.4.1.4756.20.502.20.1.528ColumnnidPort4TxVariableResponseRemoteBread-onlycurrentNID Series card Port4 Detailed Link OAM Statistics: Tx Variable Response
1.3.6.1.4.1.4756.20.502.20.1.529ColumnnidPort4TxOrgSpecificPDURemoteBread-onlycurrentNID Series card Port4 Detailed Link OAM Statistics: Tx Org Specific PDU's
1.3.6.1.4.1.4756.20.502.20.1.530ColumnnidPort4TxUnsupportedCodesRemoteBread-onlycurrentNID Series card Port4 Detailed Link OAM Statistics: Tx Unsupported Codes
1.3.6.1.4.1.4756.20.502.20.1.531ColumnnidPort4TxLinkFaultPDURemoteBread-onlycurrentNID Series card Port4 Detailed Link OAM Statistics: Tx Link Fault PDU's
1.3.6.1.4.1.4756.20.502.20.1.532ColumnnidPort4TxDyingGaspRemoteBread-onlycurrentNID Series card Port4 Detailed Link OAM Statistics: Tx Dying Gasp
1.3.6.1.4.1.4756.20.502.20.1.533ColumnnidPort4TxCriticalEventPDURemoteBread-onlycurrentNID Series card Port4 Detailed Link OAM Statistics: Tx Dying Gasp
1.3.6.1.4.1.4756.20.502.20.1.534ColumnnidPort5RxOAMInfoPDURemoteBread-onlycurrentNID Series card Port5 Detailed Link OAM Statistics: Rx OAM Information PDU's
1.3.6.1.4.1.4756.20.502.20.1.535ColumnnidPort5RxUniqueErrorEventRemoteBread-onlycurrentNID Series card Port5 Detailed Link OAM Statistics: Rx Unique Error Event Notificatio
1.3.6.1.4.1.4756.20.502.20.1.536ColumnnidPort5RxDuplicateErrorEventRemoteBread-onlycurrentNID Series card Port5 Detailed Link OAM Statistics: Rx Duplicate Error Event Notification
1.3.6.1.4.1.4756.20.502.20.1.537ColumnnidPort5RxLoopBackControlRemoteBread-onlycurrentNID Series card Port5 Detailed Link OAM Statistics: Rx Loopback Control
1.3.6.1.4.1.4756.20.502.20.1.538ColumnnidPort5RxVariableRequestRemoteBread-onlycurrentNID Series card Port5 Detailed Link OAM Statistics: Rx Variable Request
1.3.6.1.4.1.4756.20.502.20.1.539ColumnnidPort5RxVariableResponseRemoteBread-onlycurrentNID Series card Port5 Detailed Link OAM Statistics: Rx Variable Response
1.3.6.1.4.1.4756.20.502.20.1.540ColumnnidPort5RxOrgSpecificPDURemoteBread-onlycurrentNID Series card Port5 Detailed Link OAM Statistics: Rx Org Specific PDU's
1.3.6.1.4.1.4756.20.502.20.1.541ColumnnidPort5RxUnsupportedCodesRemoteBread-onlycurrentNID Series card Port5 Detailed Link OAM Statistics: Rx Unsupported Codes
1.3.6.1.4.1.4756.20.502.20.1.542ColumnnidPort5RxLinkFaultPDURemoteBread-onlycurrentNID Series card Port5 Detailed Link OAM Statistics: Rx Link Fault PDU's
1.3.6.1.4.1.4756.20.502.20.1.543ColumnnidPort5RxDyingGaspRemoteBread-onlycurrentNID Series card Port5 Detailed Link OAM Statistics: Rx Dying Gasp
1.3.6.1.4.1.4756.20.502.20.1.544ColumnnidPort5RxCriticalEventPDURemoteBread-onlycurrentNID Series card Port5 Detailed Link OAM Statistics: Rx Dying Gasp
1.3.6.1.4.1.4756.20.502.20.1.545ColumnnidPort5TxOAMInfoPDURemoteBread-onlycurrentNID Series card Port5 Detailed Link OAM Statistics: Tx OAM Information PDU's
1.3.6.1.4.1.4756.20.502.20.1.546ColumnnidPort5TxUniqueErrorEventRemoteBread-onlycurrentNID Series card Port5 Detailed Link OAM Statistics: Tx Unique Error Event Notificatio
1.3.6.1.4.1.4756.20.502.20.1.547ColumnnidPort5TxDuplicateErrorEventRemoteBread-onlycurrentNID Series card Port5 Detailed Link OAM Statistics: Tx Duplicate Error Event Notification
1.3.6.1.4.1.4756.20.502.20.1.548ColumnnidPort5TxLoopBackControlRemoteBread-onlycurrentNID Series card Port5 Detailed Link OAM Statistics: Tx Loopback Control
1.3.6.1.4.1.4756.20.502.20.1.549ColumnnidPort5TxVariableRequestRemoteBread-onlycurrentNID Series card Port5 Detailed Link OAM Statistics: Tx Variable Request
1.3.6.1.4.1.4756.20.502.20.1.550ColumnnidPort5TxVariableResponseRemoteBread-onlycurrentNID Series card Port5 Detailed Link OAM Statistics: Tx Variable Response
1.3.6.1.4.1.4756.20.502.20.1.551ColumnnidPort5TxOrgSpecificPDURemoteBread-onlycurrentNID Series card Port5 Detailed Link OAM Statistics: Tx Org Specific PDU's
1.3.6.1.4.1.4756.20.502.20.1.552ColumnnidPort5TxUnsupportedCodesRemoteBread-onlycurrentNID Series card Port5 Detailed Link OAM Statistics: Tx Unsupported Codes
1.3.6.1.4.1.4756.20.502.20.1.553ColumnnidPort5TxLinkFaultPDURemoteBread-onlycurrentNID Series card Port5 Detailed Link OAM Statistics: Tx Link Fault PDU's
1.3.6.1.4.1.4756.20.502.20.1.554ColumnnidPort5TxDyingGaspRemoteBread-onlycurrentNID Series card Port5 Detailed Link OAM Statistics: Tx Dying Gasp
1.3.6.1.4.1.4756.20.502.20.1.555ColumnnidPort5TxCriticalEventPDURemoteBread-onlycurrentNID Series card Port5 Detailed Link OAM Statistics: Tx Dying Gasp
1.3.6.1.4.1.4756.20.502.20.1.556ColumnnidPort6RxOAMInfoPDURemoteBread-onlycurrentNID Series card Port6 Detailed Link OAM Statistics: Rx OAM Information PDU's
1.3.6.1.4.1.4756.20.502.20.1.557ColumnnidPort6RxUniqueErrorEventRemoteBread-onlycurrentNID Series card Port6 Detailed Link OAM Statistics: Rx Unique Error Event Notificatio
1.3.6.1.4.1.4756.20.502.20.1.558ColumnnidPort6RxDuplicateErrorEventRemoteBread-onlycurrentNID Series card Port6 Detailed Link OAM Statistics: Rx Duplicate Error Event Notification
1.3.6.1.4.1.4756.20.502.20.1.559ColumnnidPort6RxLoopBackControlRemoteBread-onlycurrentNID Series card Port6 Detailed Link OAM Statistics: Rx Loopback Control
1.3.6.1.4.1.4756.20.502.20.1.560ColumnnidPort6RxVariableRequestRemoteBread-onlycurrentNID Series card Port6 Detailed Link OAM Statistics: Rx Variable Request
1.3.6.1.4.1.4756.20.502.20.1.561ColumnnidPort6RxVariableResponseRemoteBread-onlycurrentNID Series card Port6 Detailed Link OAM Statistics: Rx Variable Response
1.3.6.1.4.1.4756.20.502.20.1.562ColumnnidPort6RxOrgSpecificPDURemoteBread-onlycurrentNID Series card Port6 Detailed Link OAM Statistics: Rx Org Specific PDU's
1.3.6.1.4.1.4756.20.502.20.1.563ColumnnidPort6RxUnsupportedCodesRemoteBread-onlycurrentNID Series card Port6 Detailed Link OAM Statistics: Rx Unsupported Codes
1.3.6.1.4.1.4756.20.502.20.1.564ColumnnidPort6RxLinkFaultPDURemoteBread-onlycurrentNID Series card Port6 Detailed Link OAM Statistics: Rx Link Fault PDU's
1.3.6.1.4.1.4756.20.502.20.1.565ColumnnidPort6RxDyingGaspRemoteBread-onlycurrentNID Series card Port6 Detailed Link OAM Statistics: Rx Dying Gasp
1.3.6.1.4.1.4756.20.502.20.1.566ColumnnidPort6RxCriticalEventPDURemoteBread-onlycurrentNID Series card Port6 Detailed Link OAM Statistics: Rx Dying Gasp
1.3.6.1.4.1.4756.20.502.20.1.567ColumnnidPort6TxOAMInfoPDURemoteBread-onlycurrentNID Series card Port6 Detailed Link OAM Statistics: Tx OAM Information PDU's
1.3.6.1.4.1.4756.20.502.20.1.568ColumnnidPort6TxUniqueErrorEventRemoteBread-onlycurrentNID Series card Port6 Detailed Link OAM Statistics: Tx Unique Error Event Notificatio
1.3.6.1.4.1.4756.20.502.20.1.569ColumnnidPort6TxDuplicateErrorEventRemoteBread-onlycurrentNID Series card Port6 Detailed Link OAM Statistics: Tx Duplicate Error Event Notification
1.3.6.1.4.1.4756.20.502.20.1.570ColumnnidPort6TxLoopBackControlRemoteBread-onlycurrentNID Series card Port6 Detailed Link OAM Statistics: Tx Loopback Control
1.3.6.1.4.1.4756.20.502.20.1.571ColumnnidPort6TxVariableRequestRemoteBread-onlycurrentNID Series card Port6 Detailed Link OAM Statistics: Tx Variable Request
1.3.6.1.4.1.4756.20.502.20.1.572ColumnnidPort6TxVariableResponseRemoteBread-onlycurrentNID Series card Port6 Detailed Link OAM Statistics: Tx Variable Response
1.3.6.1.4.1.4756.20.502.20.1.573ColumnnidPort6TxOrgSpecificPDURemoteBread-onlycurrentNID Series card Port6 Detailed Link OAM Statistics: Tx Org Specific PDU's
1.3.6.1.4.1.4756.20.502.20.1.574ColumnnidPort6TxUnsupportedCodesRemoteBread-onlycurrentNID Series card Port6 Detailed Link OAM Statistics: Tx Unsupported Codes
1.3.6.1.4.1.4756.20.502.20.1.575ColumnnidPort6TxLinkFaultPDURemoteBread-onlycurrentNID Series card Port6 Detailed Link OAM Statistics: Tx Link Fault PDU's
1.3.6.1.4.1.4756.20.502.20.1.576ColumnnidPort6TxDyingGaspRemoteBread-onlycurrentNID Series card Port6 Detailed Link OAM Statistics: Tx Dying Gasp
1.3.6.1.4.1.4756.20.502.20.1.577ColumnnidPort6TxCriticalEventPDURemoteBread-onlycurrentNID Series card Port6 Detailed Link OAM Statistics: Tx Dying Gasp
1.3.6.1.4.1.4756.20.502.20.1.578ColumnnidPort7RxOAMInfoPDURemoteBread-onlycurrentNID Series card Port7 Detailed Link OAM Statistics: Rx OAM Information PDU's
1.3.6.1.4.1.4756.20.502.20.1.579ColumnnidPort7RxUniqueErrorEventRemoteBread-onlycurrentNID Series card Port7 Detailed Link OAM Statistics: Rx Unique Error Event Notificatio
1.3.6.1.4.1.4756.20.502.20.1.580ColumnnidPort7RxDuplicateErrorEventRemoteBread-onlycurrentNID Series card Port7 Detailed Link OAM Statistics: Rx Duplicate Error Event Notification
1.3.6.1.4.1.4756.20.502.20.1.581ColumnnidPort7RxLoopBackControlRemoteBread-onlycurrentNID Series card Port7 Detailed Link OAM Statistics: Rx Loopback Control
1.3.6.1.4.1.4756.20.502.20.1.582ColumnnidPort7RxVariableRequestRemoteBread-onlycurrentNID Series card Port7 Detailed Link OAM Statistics: Rx Variable Request
1.3.6.1.4.1.4756.20.502.20.1.583ColumnnidPort7RxVariableResponseRemoteBread-onlycurrentNID Series card Port7 Detailed Link OAM Statistics: Rx Variable Response
1.3.6.1.4.1.4756.20.502.20.1.584ColumnnidPort7RxOrgSpecificPDURemoteBread-onlycurrentNID Series card Port7 Detailed Link OAM Statistics: Rx Org Specific PDU's
1.3.6.1.4.1.4756.20.502.20.1.585ColumnnidPort7RxUnsupportedCodesRemoteBread-onlycurrentNID Series card Port7 Detailed Link OAM Statistics: Rx Unsupported Codes
1.3.6.1.4.1.4756.20.502.20.1.586ColumnnidPort7RxLinkFaultPDURemoteBread-onlycurrentNID Series card Port7 Detailed Link OAM Statistics: Rx Link Fault PDU's
1.3.6.1.4.1.4756.20.502.20.1.587ColumnnidPort7RxDyingGaspRemoteBread-onlycurrentNID Series card Port7 Detailed Link OAM Statistics: Rx Dying Gasp
1.3.6.1.4.1.4756.20.502.20.1.588ColumnnidPort7RxCriticalEventPDURemoteBread-onlycurrentNID Series card Port7 Detailed Link OAM Statistics: Rx Dying Gasp
1.3.6.1.4.1.4756.20.502.20.1.589ColumnnidPort7TxOAMInfoPDURemoteBread-onlycurrentNID Series card Port7 Detailed Link OAM Statistics: Tx OAM Information PDU's
1.3.6.1.4.1.4756.20.502.20.1.590ColumnnidPort7TxUniqueErrorEventRemoteBread-onlycurrentNID Series card Port7 Detailed Link OAM Statistics: Tx Unique Error Event Notificatio
1.3.6.1.4.1.4756.20.502.20.1.591ColumnnidPort7TxDuplicateErrorEventRemoteBread-onlycurrentNID Series card Port7 Detailed Link OAM Statistics: Tx Duplicate Error Event Notification
1.3.6.1.4.1.4756.20.502.20.1.592ColumnnidPort7TxLoopBackControlRemoteBread-onlycurrentNID Series card Port7 Detailed Link OAM Statistics: Tx Loopback Control
1.3.6.1.4.1.4756.20.502.20.1.593ColumnnidPort7TxVariableRequestRemoteBread-onlycurrentNID Series card Port7 Detailed Link OAM Statistics: Tx Variable Request
1.3.6.1.4.1.4756.20.502.20.1.594ColumnnidPort7TxVariableResponseRemoteBread-onlycurrentNID Series card Port7 Detailed Link OAM Statistics: Tx Variable Response
1.3.6.1.4.1.4756.20.502.20.1.595ColumnnidPort7TxOrgSpecificPDURemoteBread-onlycurrentNID Series card Port7 Detailed Link OAM Statistics: Tx Org Specific PDU's
1.3.6.1.4.1.4756.20.502.20.1.596ColumnnidPort7TxUnsupportedCodesRemoteBread-onlycurrentNID Series card Port7 Detailed Link OAM Statistics: Tx Unsupported Codes
1.3.6.1.4.1.4756.20.502.20.1.597ColumnnidPort7TxLinkFaultPDURemoteBread-onlycurrentNID Series card Port7 Detailed Link OAM Statistics: Tx Link Fault PDU's
1.3.6.1.4.1.4756.20.502.20.1.598ColumnnidPort7TxDyingGaspRemoteBread-onlycurrentNID Series card Port7 Detailed Link OAM Statistics: Tx Dying Gasp
1.3.6.1.4.1.4756.20.502.20.1.599ColumnnidPort7TxCriticalEventPDURemoteBread-onlycurrentNID Series card Port7 Detailed Link OAM Statistics: Tx Dying Gasp
1.3.6.1.4.1.4756.20.502.20.1.600ColumnnidPort8RxOAMInfoPDURemoteBread-onlycurrentNID Series card Port8 Detailed Link OAM Statistics: Rx OAM Information PDU's
1.3.6.1.4.1.4756.20.502.20.1.601ColumnnidPort8RxUniqueErrorEventRemoteBread-onlycurrentNID Series card Port8 Detailed Link OAM Statistics: Rx Unique Error Event Notificatio
1.3.6.1.4.1.4756.20.502.20.1.602ColumnnidPort8RxDuplicateErrorEventRemoteBread-onlycurrentNID Series card Port8 Detailed Link OAM Statistics: Rx Duplicate Error Event Notification
1.3.6.1.4.1.4756.20.502.20.1.603ColumnnidPort8RxLoopBackControlRemoteBread-onlycurrentNID Series card Port8 Detailed Link OAM Statistics: Rx Loopback Control
1.3.6.1.4.1.4756.20.502.20.1.604ColumnnidPort8RxVariableRequestRemoteBread-onlycurrentNID Series card Port8 Detailed Link OAM Statistics: Rx Variable Request
1.3.6.1.4.1.4756.20.502.20.1.605ColumnnidPort8RxVariableResponseRemoteBread-onlycurrentNID Series card Port8 Detailed Link OAM Statistics: Rx Variable Response
1.3.6.1.4.1.4756.20.502.20.1.606ColumnnidPort8RxOrgSpecificPDURemoteBread-onlycurrentNID Series card Port8 Detailed Link OAM Statistics: Rx Org Specific PDU's
1.3.6.1.4.1.4756.20.502.20.1.607ColumnnidPort8RxUnsupportedCodesRemoteBread-onlycurrentNID Series card Port8 Detailed Link OAM Statistics: Rx Unsupported Codes
1.3.6.1.4.1.4756.20.502.20.1.608ColumnnidPort8RxLinkFaultPDURemoteBread-onlycurrentNID Series card Port8 Detailed Link OAM Statistics: Rx Link Fault PDU's
1.3.6.1.4.1.4756.20.502.20.1.609ColumnnidPort8RxDyingGaspRemoteBread-onlycurrentNID Series card Port8 Detailed Link OAM Statistics: Rx Dying Gasp
1.3.6.1.4.1.4756.20.502.20.1.610ColumnnidPort8RxCriticalEventPDURemoteBread-onlycurrentNID Series card Port8 Detailed Link OAM Statistics: Rx Dying Gasp
1.3.6.1.4.1.4756.20.502.20.1.611ColumnnidPort8TxOAMInfoPDURemoteBread-onlycurrentNID Series card Port8 Detailed Link OAM Statistics: Tx OAM Information PDU's
1.3.6.1.4.1.4756.20.502.20.1.612ColumnnidPort8TxUniqueErrorEventRemoteBread-onlycurrentNID Series card Port8 Detailed Link OAM Statistics: Tx Unique Error Event Notificatio
1.3.6.1.4.1.4756.20.502.20.1.613ColumnnidPort8TxDuplicateErrorEventRemoteBread-onlycurrentNID Series card Port8 Detailed Link OAM Statistics: Tx Duplicate Error Event Notification
1.3.6.1.4.1.4756.20.502.20.1.614ColumnnidPort8TxLoopBackControlRemoteBread-onlycurrentNID Series card Port8 Detailed Link OAM Statistics: Tx Loopback Control
1.3.6.1.4.1.4756.20.502.20.1.615ColumnnidPort8TxVariableRequestRemoteBread-onlycurrentNID Series card Port8 Detailed Link OAM Statistics: Tx Variable Request
1.3.6.1.4.1.4756.20.502.20.1.616ColumnnidPort8TxVariableResponseRemoteBread-onlycurrentNID Series card Port8 Detailed Link OAM Statistics: Tx Variable Response
1.3.6.1.4.1.4756.20.502.20.1.617ColumnnidPort8TxOrgSpecificPDURemoteBread-onlycurrentNID Series card Port8 Detailed Link OAM Statistics: Tx Org Specific PDU's
1.3.6.1.4.1.4756.20.502.20.1.618ColumnnidPort8TxUnsupportedCodesRemoteBread-onlycurrentNID Series card Port8 Detailed Link OAM Statistics: Tx Unsupported Codes
1.3.6.1.4.1.4756.20.502.20.1.619ColumnnidPort8TxLinkFaultPDURemoteBread-onlycurrentNID Series card Port8 Detailed Link OAM Statistics: Tx Link Fault PDU's
1.3.6.1.4.1.4756.20.502.20.1.620ColumnnidPort8TxDyingGaspRemoteBread-onlycurrentNID Series card Port8 Detailed Link OAM Statistics: Tx Dying Gasp
1.3.6.1.4.1.4756.20.502.20.1.621ColumnnidPort8TxCriticalEventPDURemoteBread-onlycurrentNID Series card Port8 Detailed Link OAM Statistics: Tx Dying Gasp
1.3.6.1.4.1.4756.20.502.20.1.622ColumnnidPort1PDUPermisionRemoteBread-onlycurrentNID Series card Detailed Link OAM Status for Port 1: PDU Permission
1.3.6.1.4.1.4756.20.502.20.1.623ColumnnidPort1DiscoveryStateRemoteBread-onlycurrentNID Series card Detailed Link OAM Status for Port 1: Discovery State
1.3.6.1.4.1.4756.20.502.20.1.624ColumnnidPort1PeerMACAddrRemoteBread-onlycurrentNID Series card Detailed Link OAM Status for Port 1: Discovery State
1.3.6.1.4.1.4756.20.502.20.1.625ColumnnidPort1RemoteBModeRemoteBread-onlycurrentNID Series card Detailed Link OAM Status for Port 1: RemoteB: Mode
1.3.6.1.4.1.4756.20.502.20.1.626ColumnnidPort1RemoteBUnOperationRemoteBread-onlycurrentNID Series card Detailed Link OAM Status for Port 1: RemoteB: Unidirectional Operation Support
1.3.6.1.4.1.4756.20.502.20.1.627ColumnnidPort1RemoteBRemoteLbRemoteBread-onlycurrentNID Series card Detailed Link OAM Status for Port 1: RemoteB: Remote Loopback Support
1.3.6.1.4.1.4756.20.502.20.1.628ColumnnidPort1RemoteBLMRemoteBread-onlycurrentNID Series card Detailed Link OAM Status for Port 1: RemoteB: Link Monitoring Support
1.3.6.1.4.1.4756.20.502.20.1.629ColumnnidPort1RemoteBMIBRetrievalRemoteBread-onlycurrentNID Series card Detailed Link OAM Status for Port 1: RemoteB: MIB Retrieval Support
1.3.6.1.4.1.4756.20.502.20.1.630ColumnnidPort1RemoteBMTUSizeRemoteBread-onlycurrentNID Series card Detailed Link OAM Status for Port 1: RemoteB: MTU Size
1.3.6.1.4.1.4756.20.502.20.1.631ColumnnidPort1RemoteBMultiStateRemoteBread-onlycurrentNID Series card Detailed Link OAM Status for Port 1: RemoteB: Multiplexer State
1.3.6.1.4.1.4756.20.502.20.1.632ColumnnidPort1RemoteBParserStateRemoteBread-onlycurrentNID Series card Detailed Link OAM Status for Port 1: RemoteB: Multiplexer State
1.3.6.1.4.1.4756.20.502.20.1.633ColumnnidPort1RemoteBOUIRemoteBread-onlycurrentNID Series card Detailed Link OAM Status for Port 1: RemoteB: Organizational Unique Identification
1.3.6.1.4.1.4756.20.502.20.1.634ColumnnidPort1RemoteBPDURevRemoteBread-onlycurrentNID Series card Detailed Link OAM Status for Port 1: RemoteB: PDU Revision
1.3.6.1.4.1.4756.20.502.20.1.635ColumnnidPort1PeerModeRemoteBread-onlycurrentNID Series card Detailed Link OAM Status for Port 1: Peer: Mode
1.3.6.1.4.1.4756.20.502.20.1.636ColumnnidPort1PeerUnOperationRemoteBread-onlycurrentNID Series card Detailed Link OAM Status for Port 1: Peer: Unidirectional Operation Support
1.3.6.1.4.1.4756.20.502.20.1.637ColumnnidPort1PeerRemoteLbRemoteBread-onlycurrentNID Series card Detailed Link OAM Status for Port 1: Peer: Remote Loopback Support
1.3.6.1.4.1.4756.20.502.20.1.638ColumnnidPort1PeerLMRemoteBread-onlycurrentNID Series card Detailed Link OAM Status for Port 1: Peer: Link Monitoring Support
1.3.6.1.4.1.4756.20.502.20.1.639ColumnnidPort1PeerMIBRetrievalRemoteBread-onlycurrentNID Series card Detailed Link OAM Status for Port 1: Peer: MIB Retrieval Support
1.3.6.1.4.1.4756.20.502.20.1.640ColumnnidPort1PeerMTUSizeRemoteBread-onlycurrentNID Series card Detailed Link OAM Status for Port 1: Peer: MTU Size
1.3.6.1.4.1.4756.20.502.20.1.641ColumnnidPort1PeerMultiStateRemoteBread-onlycurrentNID Series card Detailed Link OAM Status for Port 1: Peer: Multiplexer State
1.3.6.1.4.1.4756.20.502.20.1.642ColumnnidPort1PeerParserStateRemoteBread-onlycurrentNID Series card Detailed Link OAM Status for Port 1: Peer: Multiplexer State
1.3.6.1.4.1.4756.20.502.20.1.643ColumnnidPort1PeerOUIRemoteBread-onlycurrentNID Series card Detailed Link OAM Status for Port 1: Peer: Organizational Unique Identification
1.3.6.1.4.1.4756.20.502.20.1.644ColumnnidPort1PeerPDURevRemoteBread-onlycurrentNID Series card Detailed Link OAM Status for Port 1: Peer: PDU Revision
1.3.6.1.4.1.4756.20.502.20.1.645ColumnnidPort2PDUPermisionRemoteBread-onlycurrentNID Series card Detailed Link OAM Status for Port 2: PDU Permission
1.3.6.1.4.1.4756.20.502.20.1.646ColumnnidPort2DiscoveryStateRemoteBread-onlycurrentNID Series card Detailed Link OAM Status for Port 2: Discovery State
1.3.6.1.4.1.4756.20.502.20.1.647ColumnnidPort2PeerMACAddrRemoteBread-onlycurrentNID Series card Detailed Link OAM Status for Port 2: Discovery State
1.3.6.1.4.1.4756.20.502.20.1.648ColumnnidPort2RemoteBModeRemoteBread-onlycurrentNID Series card Detailed Link OAM Status for Port 2: RemoteB: Mode
1.3.6.1.4.1.4756.20.502.20.1.649ColumnnidPort2RemoteBUnOperationRemoteBread-onlycurrentNID Series card Detailed Link OAM Status for Port 2: RemoteB: Unidirectional Operation Support
1.3.6.1.4.1.4756.20.502.20.1.650ColumnnidPort2RemoteBRemoteLbRemoteBread-onlycurrentNID Series card Detailed Link OAM Status for Port 2: RemoteB: Remote Loopback Support
1.3.6.1.4.1.4756.20.502.20.1.651ColumnnidPort2RemoteBLMRemoteBread-onlycurrentNID Series card Detailed Link OAM Status for Port 2: RemoteB: Link Monitoring Support
1.3.6.1.4.1.4756.20.502.20.1.652ColumnnidPort2RemoteBMIBRetrievalRemoteBread-onlycurrentNID Series card Detailed Link OAM Status for Port 2: RemoteB: MIB Retrieval Support
1.3.6.1.4.1.4756.20.502.20.1.653ColumnnidPort2RemoteBMTUSizeRemoteBread-onlycurrentNID Series card Detailed Link OAM Status for Port 2: RemoteB: MTU Size
1.3.6.1.4.1.4756.20.502.20.1.654ColumnnidPort2RemoteBMultiStateRemoteBread-onlycurrentNID Series card Detailed Link OAM Status for Port 2: RemoteB: Multiplexer State
1.3.6.1.4.1.4756.20.502.20.1.655ColumnnidPort2RemoteBParserStateRemoteBread-onlycurrentNID Series card Detailed Link OAM Status for Port 2: RemoteB: Multiplexer State
1.3.6.1.4.1.4756.20.502.20.1.656ColumnnidPort2RemoteBOUIRemoteBread-onlycurrentNID Series card Detailed Link OAM Status for Port 2: RemoteB: Organizational Unique Identification
1.3.6.1.4.1.4756.20.502.20.1.657ColumnnidPort2RemoteBPDURevRemoteBread-onlycurrentNID Series card Detailed Link OAM Status for Port 2: RemoteB: PDU Revision
1.3.6.1.4.1.4756.20.502.20.1.658ColumnnidPort2PeerModeRemoteBread-onlycurrentNID Series card Detailed Link OAM Status for Port 2: Peer: Mode
1.3.6.1.4.1.4756.20.502.20.1.659ColumnnidPort2PeerUnOperationRemoteBread-onlycurrentNID Series card Detailed Link OAM Status for Port 2: Peer: Unidirectional Operation Support
1.3.6.1.4.1.4756.20.502.20.1.660ColumnnidPort2PeerRemoteLbRemoteBread-onlycurrentNID Series card Detailed Link OAM Status for Port 2: Peer: Remote Loopback Support
1.3.6.1.4.1.4756.20.502.20.1.661ColumnnidPort2PeerLMRemoteBread-onlycurrentNID Series card Detailed Link OAM Status for Port 2: Peer: Link Monitoring Support
1.3.6.1.4.1.4756.20.502.20.1.662ColumnnidPort2PeerMIBRetrievalRemoteBread-onlycurrentNID Series card Detailed Link OAM Status for Port 2: Peer: MIB Retrieval Support
1.3.6.1.4.1.4756.20.502.20.1.663ColumnnidPort2PeerMTUSizeRemoteBread-onlycurrentNID Series card Detailed Link OAM Status for Port 2: Peer: MTU Size
1.3.6.1.4.1.4756.20.502.20.1.664ColumnnidPort2PeerMultiStateRemoteBread-onlycurrentNID Series card Detailed Link OAM Status for Port 2: Peer: Multiplexer State
1.3.6.1.4.1.4756.20.502.20.1.665ColumnnidPort2PeerParserStateRemoteBread-onlycurrentNID Series card Detailed Link OAM Status for Port 2: Peer: Multiplexer State
1.3.6.1.4.1.4756.20.502.20.1.666ColumnnidPort2PeerOUIRemoteBread-onlycurrentNID Series card Detailed Link OAM Status for Port 2: Peer: Organizational Unique Identification
1.3.6.1.4.1.4756.20.502.20.1.667ColumnnidPort2PeerPDURevRemoteBread-onlycurrentNID Series card Detailed Link OAM Status for Port 2: Peer: PDU Revision
1.3.6.1.4.1.4756.20.502.20.1.668ColumnnidPort3PDUPermisionRemoteBread-onlycurrentNID Series card Detailed Link OAM Status for Port 3: PDU Permission
1.3.6.1.4.1.4756.20.502.20.1.669ColumnnidPort3DiscoveryStateRemoteBread-onlycurrentNID Series card Detailed Link OAM Status for Port 3: Discovery State
1.3.6.1.4.1.4756.20.502.20.1.670ColumnnidPort3PeerMACAddrRemoteBread-onlycurrentNID Series card Detailed Link OAM Status for Port 3: Discovery State
1.3.6.1.4.1.4756.20.502.20.1.671ColumnnidPort3RemoteBModeRemoteBread-onlycurrentNID Series card Detailed Link OAM Status for Port 3: RemoteB: Mode
1.3.6.1.4.1.4756.20.502.20.1.672ColumnnidPort3RemoteBUnOperationRemoteBread-onlycurrentNID Series card Detailed Link OAM Status for Port 3: RemoteB: Unidirectional Operation Support
1.3.6.1.4.1.4756.20.502.20.1.673ColumnnidPort3RemoteBRemoteLbRemoteBread-onlycurrentNID Series card Detailed Link OAM Status for Port 3: RemoteB: Remote Loopback Support
1.3.6.1.4.1.4756.20.502.20.1.674ColumnnidPort3RemoteBLMRemoteBread-onlycurrentNID Series card Detailed Link OAM Status for Port 3: RemoteB: Link Monitoring Support
1.3.6.1.4.1.4756.20.502.20.1.675ColumnnidPort3RemoteBMIBRetrievalRemoteBread-onlycurrentNID Series card Detailed Link OAM Status for Port 3: RemoteB: MIB Retrieval Support
1.3.6.1.4.1.4756.20.502.20.1.676ColumnnidPort3RemoteBMTUSizeRemoteBread-onlycurrentNID Series card Detailed Link OAM Status for Port 3: RemoteB: MTU Size
1.3.6.1.4.1.4756.20.502.20.1.677ColumnnidPort3RemoteBMultiStateRemoteBread-onlycurrentNID Series card Detailed Link OAM Status for Port 3: RemoteB: Multiplexer State
1.3.6.1.4.1.4756.20.502.20.1.678ColumnnidPort3RemoteBParserStateRemoteBread-onlycurrentNID Series card Detailed Link OAM Status for Port 3: RemoteB: Multiplexer State
1.3.6.1.4.1.4756.20.502.20.1.679ColumnnidPort3RemoteBOUIRemoteBread-onlycurrentNID Series card Detailed Link OAM Status for Port 3: RemoteB: Organizational Unique Identification
1.3.6.1.4.1.4756.20.502.20.1.680ColumnnidPort3RemoteBPDURevRemoteBread-onlycurrentNID Series card Detailed Link OAM Status for Port 3: RemoteB: PDU Revision
1.3.6.1.4.1.4756.20.502.20.1.681ColumnnidPort3PeerModeRemoteBread-onlycurrentNID Series card Detailed Link OAM Status for Port 3: Peer: Mode
1.3.6.1.4.1.4756.20.502.20.1.682ColumnnidPort3PeerUnOperationRemoteBread-onlycurrentNID Series card Detailed Link OAM Status for Port 3: Peer: Unidirectional Operation Support
1.3.6.1.4.1.4756.20.502.20.1.683ColumnnidPort3PeerRemoteLbRemoteBread-onlycurrentNID Series card Detailed Link OAM Status for Port 3: Peer: Remote Loopback Support
1.3.6.1.4.1.4756.20.502.20.1.684ColumnnidPort3PeerLMRemoteBread-onlycurrentNID Series card Detailed Link OAM Status for Port 3: Peer: Link Monitoring Support
1.3.6.1.4.1.4756.20.502.20.1.685ColumnnidPort3PeerMIBRetrievalRemoteBread-onlycurrentNID Series card Detailed Link OAM Status for Port 3: Peer: MIB Retrieval Support
1.3.6.1.4.1.4756.20.502.20.1.686ColumnnidPort3PeerMTUSizeRemoteBread-onlycurrentNID Series card Detailed Link OAM Status for Port 3: Peer: MTU Size
1.3.6.1.4.1.4756.20.502.20.1.687ColumnnidPort3PeerMultiStateRemoteBread-onlycurrentNID Series card Detailed Link OAM Status for Port 3: Peer: Multiplexer State
1.3.6.1.4.1.4756.20.502.20.1.688ColumnnidPort3PeerParserStateRemoteBread-onlycurrentNID Series card Detailed Link OAM Status for Port 3: Peer: Multiplexer State
1.3.6.1.4.1.4756.20.502.20.1.689ColumnnidPort3PeerOUIRemoteBread-onlycurrentNID Series card Detailed Link OAM Status for Port 3: Peer: Organizational Unique Identification
1.3.6.1.4.1.4756.20.502.20.1.690ColumnnidPort3PeerPDURevRemoteBread-onlycurrentNID Series card Detailed Link OAM Status for Port 3: Peer: PDU Revision
1.3.6.1.4.1.4756.20.502.20.1.691ColumnnidPort4PDUPermisionRemoteBread-onlycurrentNID Series card Detailed Link OAM Status for Port 4: PDU Permission
1.3.6.1.4.1.4756.20.502.20.1.692ColumnnidPort4DiscoveryStateRemoteBread-onlycurrentNID Series card Detailed Link OAM Status for Port 4: Discovery State
1.3.6.1.4.1.4756.20.502.20.1.693ColumnnidPort4PeerMACAddrRemoteBread-onlycurrentNID Series card Detailed Link OAM Status for Port 4: Discovery State
1.3.6.1.4.1.4756.20.502.20.1.694ColumnnidPort4RemoteBModeRemoteBread-onlycurrentNID Series card Detailed Link OAM Status for Port 4: RemoteB: Mode
1.3.6.1.4.1.4756.20.502.20.1.695ColumnnidPort4RemoteBUnOperationRemoteBread-onlycurrentNID Series card Detailed Link OAM Status for Port 4: RemoteB: Unidirectional Operation Support
1.3.6.1.4.1.4756.20.502.20.1.696ColumnnidPort4RemoteBRemoteLbRemoteBread-onlycurrentNID Series card Detailed Link OAM Status for Port 4: RemoteB: Remote Loopback Support
1.3.6.1.4.1.4756.20.502.20.1.697ColumnnidPort4RemoteBLMRemoteBread-onlycurrentNID Series card Detailed Link OAM Status for Port 4: RemoteB: Link Monitoring Support
1.3.6.1.4.1.4756.20.502.20.1.698ColumnnidPort4RemoteBMIBRetrievalRemoteBread-onlycurrentNID Series card Detailed Link OAM Status for Port 4: RemoteB: MIB Retrieval Support
1.3.6.1.4.1.4756.20.502.20.1.699ColumnnidPort4RemoteBMTUSizeRemoteBread-onlycurrentNID Series card Detailed Link OAM Status for Port 4: RemoteB: MTU Size
1.3.6.1.4.1.4756.20.502.20.1.700ColumnnidPort4RemoteBMultiStateRemoteBread-onlycurrentNID Series card Detailed Link OAM Status for Port 4: RemoteB: Multiplexer State
1.3.6.1.4.1.4756.20.502.20.1.701ColumnnidPort4RemoteBParserStateRemoteBread-onlycurrentNID Series card Detailed Link OAM Status for Port 4: RemoteB: Multiplexer State
1.3.6.1.4.1.4756.20.502.20.1.702ColumnnidPort4RemoteBOUIRemoteBread-onlycurrentNID Series card Detailed Link OAM Status for Port 4: RemoteB: Organizational Unique Identification
1.3.6.1.4.1.4756.20.502.20.1.703ColumnnidPort4RemoteBPDURevRemoteBread-onlycurrentNID Series card Detailed Link OAM Status for Port 4: RemoteB: PDU Revision
1.3.6.1.4.1.4756.20.502.20.1.704ColumnnidPort4PeerModeRemoteBread-onlycurrentNID Series card Detailed Link OAM Status for Port 4: Peer: Mode
1.3.6.1.4.1.4756.20.502.20.1.705ColumnnidPort4PeerUnOperationRemoteBread-onlycurrentNID Series card Detailed Link OAM Status for Port 4: Peer: Unidirectional Operation Support
1.3.6.1.4.1.4756.20.502.20.1.706ColumnnidPort4PeerRemoteLbRemoteBread-onlycurrentNID Series card Detailed Link OAM Status for Port 4: Peer: Remote Loopback Support
1.3.6.1.4.1.4756.20.502.20.1.707ColumnnidPort4PeerLMRemoteBread-onlycurrentNID Series card Detailed Link OAM Status for Port 4: Peer: Link Monitoring Support
1.3.6.1.4.1.4756.20.502.20.1.708ColumnnidPort4PeerMIBRetrievalRemoteBread-onlycurrentNID Series card Detailed Link OAM Status for Port 4: Peer: MIB Retrieval Support
1.3.6.1.4.1.4756.20.502.20.1.709ColumnnidPort4PeerMTUSizeRemoteBread-onlycurrentNID Series card Detailed Link OAM Status for Port 4: Peer: MTU Size
1.3.6.1.4.1.4756.20.502.20.1.710ColumnnidPort4PeerMultiStateRemoteBread-onlycurrentNID Series card Detailed Link OAM Status for Port 4: Peer: Multiplexer State
1.3.6.1.4.1.4756.20.502.20.1.711ColumnnidPort4PeerParserStateRemoteBread-onlycurrentNID Series card Detailed Link OAM Status for Port 4: Peer: Multiplexer State
1.3.6.1.4.1.4756.20.502.20.1.712ColumnnidPort4PeerOUIRemoteBread-onlycurrentNID Series card Detailed Link OAM Status for Port 4: Peer: Organizational Unique Identification
1.3.6.1.4.1.4756.20.502.20.1.713ColumnnidPort4PeerPDURevRemoteBread-onlycurrentNID Series card Detailed Link OAM Status for Port 4: Peer: PDU Revision
1.3.6.1.4.1.4756.20.502.20.1.714ColumnnidPort5PDUPermisionRemoteBread-onlycurrentNID Series card Detailed Link OAM Status for Port 5: PDU Permission
1.3.6.1.4.1.4756.20.502.20.1.715ColumnnidPort5DiscoveryStateRemoteBread-onlycurrentNID Series card Detailed Link OAM Status for Port 5: Discovery State
1.3.6.1.4.1.4756.20.502.20.1.716ColumnnidPort5PeerMACAddrRemoteBread-onlycurrentNID Series card Detailed Link OAM Status for Port 5: Discovery State
1.3.6.1.4.1.4756.20.502.20.1.717ColumnnidPort5RemoteBModeRemoteBread-onlycurrentNID Series card Detailed Link OAM Status for Port 5: RemoteB: Mode
1.3.6.1.4.1.4756.20.502.20.1.718ColumnnidPort5RemoteBUnOperationRemoteBread-onlycurrentNID Series card Detailed Link OAM Status for Port 5: RemoteB: Unidirectional Operation Support
1.3.6.1.4.1.4756.20.502.20.1.719ColumnnidPort5RemoteBRemoteLbRemoteBread-onlycurrentNID Series card Detailed Link OAM Status for Port 5: RemoteB: Remote Loopback Support
1.3.6.1.4.1.4756.20.502.20.1.720ColumnnidPort5RemoteBLMRemoteBread-onlycurrentNID Series card Detailed Link OAM Status for Port 5: RemoteB: Link Monitoring Support
1.3.6.1.4.1.4756.20.502.20.1.721ColumnnidPort5RemoteBMIBRetrievalRemoteBread-onlycurrentNID Series card Detailed Link OAM Status for Port 5: RemoteB: MIB Retrieval Support
1.3.6.1.4.1.4756.20.502.20.1.722ColumnnidPort5RemoteBMTUSizeRemoteBread-onlycurrentNID Series card Detailed Link OAM Status for Port 5: RemoteB: MTU Size
1.3.6.1.4.1.4756.20.502.20.1.723ColumnnidPort5RemoteBMultiStateRemoteBread-onlycurrentNID Series card Detailed Link OAM Status for Port 5: RemoteB: Multiplexer State
1.3.6.1.4.1.4756.20.502.20.1.724ColumnnidPort5RemoteBParserStateRemoteBread-onlycurrentNID Series card Detailed Link OAM Status for Port 5: RemoteB: Multiplexer State
1.3.6.1.4.1.4756.20.502.20.1.725ColumnnidPort5RemoteBOUIRemoteBread-onlycurrentNID Series card Detailed Link OAM Status for Port 5: RemoteB: Organizational Unique Identification
1.3.6.1.4.1.4756.20.502.20.1.726ColumnnidPort5RemoteBPDURevRemoteBread-onlycurrentNID Series card Detailed Link OAM Status for Port 5: RemoteB: PDU Revision
1.3.6.1.4.1.4756.20.502.20.1.727ColumnnidPort5PeerModeRemoteBread-onlycurrentNID Series card Detailed Link OAM Status for Port 5: Peer: Mode
1.3.6.1.4.1.4756.20.502.20.1.728ColumnnidPort5PeerUnOperationRemoteBread-onlycurrentNID Series card Detailed Link OAM Status for Port 5: Peer: Unidirectional Operation Support
1.3.6.1.4.1.4756.20.502.20.1.729ColumnnidPort5PeerRemoteLbRemoteBread-onlycurrentNID Series card Detailed Link OAM Status for Port 5: Peer: Remote Loopback Support
1.3.6.1.4.1.4756.20.502.20.1.730ColumnnidPort5PeerLMRemoteBread-onlycurrentNID Series card Detailed Link OAM Status for Port 5: Peer: Link Monitoring Support
1.3.6.1.4.1.4756.20.502.20.1.731ColumnnidPort5PeerMIBRetrievalRemoteBread-onlycurrentNID Series card Detailed Link OAM Status for Port 5: Peer: MIB Retrieval Support
1.3.6.1.4.1.4756.20.502.20.1.732ColumnnidPort5PeerMTUSizeRemoteBread-onlycurrentNID Series card Detailed Link OAM Status for Port 5: Peer: MTU Size
1.3.6.1.4.1.4756.20.502.20.1.733ColumnnidPort5PeerMultiStateRemoteBread-onlycurrentNID Series card Detailed Link OAM Status for Port 5: Peer: Multiplexer State
1.3.6.1.4.1.4756.20.502.20.1.734ColumnnidPort5PeerParserStateRemoteBread-onlycurrentNID Series card Detailed Link OAM Status for Port 5: Peer: Multiplexer State
1.3.6.1.4.1.4756.20.502.20.1.735ColumnnidPort5PeerOUIRemoteBread-onlycurrentNID Series card Detailed Link OAM Status for Port 5: Peer: Organizational Unique Identification
1.3.6.1.4.1.4756.20.502.20.1.736ColumnnidPort5PeerPDURevRemoteBread-onlycurrentNID Series card Detailed Link OAM Status for Port 5: Peer: PDU Revision
1.3.6.1.4.1.4756.20.502.20.1.737ColumnnidPort6PDUPermisionRemoteBread-onlycurrentNID Series card Detailed Link OAM Status for Port 6: PDU Permission
1.3.6.1.4.1.4756.20.502.20.1.738ColumnnidPort6DiscoveryStateRemoteBread-onlycurrentNID Series card Detailed Link OAM Status for Port 6: Discovery State
1.3.6.1.4.1.4756.20.502.20.1.739ColumnnidPort6PeerMACAddrRemoteBread-onlycurrentNID Series card Detailed Link OAM Status for Port 6: Discovery State
1.3.6.1.4.1.4756.20.502.20.1.740ColumnnidPort6RemoteBModeRemoteBread-onlycurrentNID Series card Detailed Link OAM Status for Port 6: RemoteB: Mode
1.3.6.1.4.1.4756.20.502.20.1.741ColumnnidPort6RemoteBUnOperationRemoteBread-onlycurrentNID Series card Detailed Link OAM Status for Port 6: RemoteB: Unidirectional Operation Support
1.3.6.1.4.1.4756.20.502.20.1.742ColumnnidPort6RemoteBRemoteLbRemoteBread-onlycurrentNID Series card Detailed Link OAM Status for Port 6: RemoteB: Remote Loopback Support
1.3.6.1.4.1.4756.20.502.20.1.743ColumnnidPort6RemoteBLMRemoteBread-onlycurrentNID Series card Detailed Link OAM Status for Port 6: RemoteB: Link Monitoring Support
1.3.6.1.4.1.4756.20.502.20.1.744ColumnnidPort6RemoteBMIBRetrievalRemoteBread-onlycurrentNID Series card Detailed Link OAM Status for Port 6: RemoteB: MIB Retrieval Support
1.3.6.1.4.1.4756.20.502.20.1.745ColumnnidPort6RemoteBMTUSizeRemoteBread-onlycurrentNID Series card Detailed Link OAM Status for Port 6: RemoteB: MTU Size
1.3.6.1.4.1.4756.20.502.20.1.746ColumnnidPort6RemoteBMultiStateRemoteBread-onlycurrentNID Series card Detailed Link OAM Status for Port 6: RemoteB: Multiplexer State
1.3.6.1.4.1.4756.20.502.20.1.747ColumnnidPort6RemoteBParserStateRemoteBread-onlycurrentNID Series card Detailed Link OAM Status for Port 6: RemoteB: Multiplexer State
1.3.6.1.4.1.4756.20.502.20.1.748ColumnnidPort6RemoteBOUIRemoteBread-onlycurrentNID Series card Detailed Link OAM Status for Port 6: RemoteB: Organizational Unique Identification
1.3.6.1.4.1.4756.20.502.20.1.749ColumnnidPort6RemoteBPDURevRemoteBread-onlycurrentNID Series card Detailed Link OAM Status for Port 6: RemoteB: PDU Revision
1.3.6.1.4.1.4756.20.502.20.1.750ColumnnidPort6PeerModeRemoteBread-onlycurrentNID Series card Detailed Link OAM Status for Port 6: Peer: Mode
1.3.6.1.4.1.4756.20.502.20.1.751ColumnnidPort6PeerUnOperationRemoteBread-onlycurrentNID Series card Detailed Link OAM Status for Port 6: Peer: Unidirectional Operation Support
1.3.6.1.4.1.4756.20.502.20.1.752ColumnnidPort6PeerRemoteLbRemoteBread-onlycurrentNID Series card Detailed Link OAM Status for Port 6: Peer: Remote Loopback Support
1.3.6.1.4.1.4756.20.502.20.1.753ColumnnidPort6PeerLMRemoteBread-onlycurrentNID Series card Detailed Link OAM Status for Port 6: Peer: Link Monitoring Support
1.3.6.1.4.1.4756.20.502.20.1.754ColumnnidPort6PeerMIBRetrievalRemoteBread-onlycurrentNID Series card Detailed Link OAM Status for Port 6: Peer: MIB Retrieval Support
1.3.6.1.4.1.4756.20.502.20.1.755ColumnnidPort6PeerMTUSizeRemoteBread-onlycurrentNID Series card Detailed Link OAM Status for Port 6: Peer: MTU Size
1.3.6.1.4.1.4756.20.502.20.1.756ColumnnidPort6PeerMultiStateRemoteBread-onlycurrentNID Series card Detailed Link OAM Status for Port 6: Peer: Multiplexer State
1.3.6.1.4.1.4756.20.502.20.1.757ColumnnidPort6PeerParserStateRemoteBread-onlycurrentNID Series card Detailed Link OAM Status for Port 6: Peer: Multiplexer State
1.3.6.1.4.1.4756.20.502.20.1.758ColumnnidPort6PeerOUIRemoteBread-onlycurrentNID Series card Detailed Link OAM Status for Port 6: Peer: Organizational Unique Identification
1.3.6.1.4.1.4756.20.502.20.1.759ColumnnidPort6PeerPDURevRemoteBread-onlycurrentNID Series card Detailed Link OAM Status for Port 6: Peer: PDU Revision
1.3.6.1.4.1.4756.20.502.20.1.760ColumnnidPort7PDUPermisionRemoteBread-onlycurrentNID Series card Detailed Link OAM Status for Port 7: PDU Permission
1.3.6.1.4.1.4756.20.502.20.1.761ColumnnidPort7DiscoveryStateRemoteBread-onlycurrentNID Series card Detailed Link OAM Status for Port 7: Discovery State
1.3.6.1.4.1.4756.20.502.20.1.762ColumnnidPort7PeerMACAddrRemoteBread-onlycurrentNID Series card Detailed Link OAM Status for Port 7: Discovery State
1.3.6.1.4.1.4756.20.502.20.1.763ColumnnidPort7RemoteBModeRemoteBread-onlycurrentNID Series card Detailed Link OAM Status for Port 7: RemoteB: Mode
1.3.6.1.4.1.4756.20.502.20.1.764ColumnnidPort7RemoteBUnOperationRemoteBread-onlycurrentNID Series card Detailed Link OAM Status for Port 7: RemoteB: Unidirectional Operation Support
1.3.6.1.4.1.4756.20.502.20.1.765ColumnnidPort7RemoteBRemoteLbRemoteBread-onlycurrentNID Series card Detailed Link OAM Status for Port 7: RemoteB: Remote Loopback Support
1.3.6.1.4.1.4756.20.502.20.1.766ColumnnidPort7RemoteBLMRemoteBread-onlycurrentNID Series card Detailed Link OAM Status for Port 7: RemoteB: Link Monitoring Support
1.3.6.1.4.1.4756.20.502.20.1.767ColumnnidPort7RemoteBMIBRetrievalRemoteBread-onlycurrentNID Series card Detailed Link OAM Status for Port 7: RemoteB: MIB Retrieval Support
1.3.6.1.4.1.4756.20.502.20.1.768ColumnnidPort7RemoteBMTUSizeRemoteBread-onlycurrentNID Series card Detailed Link OAM Status for Port 7: RemoteB: MTU Size
1.3.6.1.4.1.4756.20.502.20.1.769ColumnnidPort7RemoteBMultiStateRemoteBread-onlycurrentNID Series card Detailed Link OAM Status for Port 7: RemoteB: Multiplexer State
1.3.6.1.4.1.4756.20.502.20.1.770ColumnnidPort7RemoteBParserStateRemoteBread-onlycurrentNID Series card Detailed Link OAM Status for Port 7: RemoteB: Multiplexer State
1.3.6.1.4.1.4756.20.502.20.1.771ColumnnidPort7RemoteBOUIRemoteBread-onlycurrentNID Series card Detailed Link OAM Status for Port 7: RemoteB: Organizational Unique Identification
1.3.6.1.4.1.4756.20.502.20.1.772ColumnnidPort7RemoteBPDURevRemoteBread-onlycurrentNID Series card Detailed Link OAM Status for Port 7: RemoteB: PDU Revision
1.3.6.1.4.1.4756.20.502.20.1.773ColumnnidPort7PeerModeRemoteBread-onlycurrentNID Series card Detailed Link OAM Status for Port 7: Peer: Mode
1.3.6.1.4.1.4756.20.502.20.1.774ColumnnidPort7PeerUnOperationRemoteBread-onlycurrentNID Series card Detailed Link OAM Status for Port 7: Peer: Unidirectional Operation Support
1.3.6.1.4.1.4756.20.502.20.1.775ColumnnidPort7PeerRemoteLbRemoteBread-onlycurrentNID Series card Detailed Link OAM Status for Port 7: Peer: Remote Loopback Support
1.3.6.1.4.1.4756.20.502.20.1.776ColumnnidPort7PeerLMRemoteBread-onlycurrentNID Series card Detailed Link OAM Status for Port 7: Peer: Link Monitoring Support
1.3.6.1.4.1.4756.20.502.20.1.777ColumnnidPort7PeerMIBRetrievalRemoteBread-onlycurrentNID Series card Detailed Link OAM Status for Port 7: Peer: MIB Retrieval Support
1.3.6.1.4.1.4756.20.502.20.1.778ColumnnidPort7PeerMTUSizeRemoteBread-onlycurrentNID Series card Detailed Link OAM Status for Port 7: Peer: MTU Size
1.3.6.1.4.1.4756.20.502.20.1.779ColumnnidPort7PeerMultiStateRemoteBread-onlycurrentNID Series card Detailed Link OAM Status for Port 7: Peer: Multiplexer State
1.3.6.1.4.1.4756.20.502.20.1.780ColumnnidPort7PeerParserStateRemoteBread-onlycurrentNID Series card Detailed Link OAM Status for Port 7: Peer: Multiplexer State
1.3.6.1.4.1.4756.20.502.20.1.781ColumnnidPort7PeerOUIRemoteBread-onlycurrentNID Series card Detailed Link OAM Status for Port 7: Peer: Organizational Unique Identification
1.3.6.1.4.1.4756.20.502.20.1.782ColumnnidPort7PeerPDURevRemoteBread-onlycurrentNID Series card Detailed Link OAM Status for Port 7: Peer: PDU Revision
1.3.6.1.4.1.4756.20.502.20.1.783ColumnnidPort8PDUPermisionRemoteBread-onlycurrentNID Series card Detailed Link OAM Status for Port 8: PDU Permission
1.3.6.1.4.1.4756.20.502.20.1.784ColumnnidPort8DiscoveryStateRemoteBread-onlycurrentNID Series card Detailed Link OAM Status for Port 8: Discovery State
1.3.6.1.4.1.4756.20.502.20.1.785ColumnnidPort8PeerMACAddrRemoteBread-onlycurrentNID Series card Detailed Link OAM Status for Port 8: Discovery State
1.3.6.1.4.1.4756.20.502.20.1.786ColumnnidPort8RemoteBModeRemoteBread-onlycurrentNID Series card Detailed Link OAM Status for Port 8: RemoteB: Mode
1.3.6.1.4.1.4756.20.502.20.1.787ColumnnidPort8RemoteBUnOperationRemoteBread-onlycurrentNID Series card Detailed Link OAM Status for Port 8: RemoteB: Unidirectional Operation Support
1.3.6.1.4.1.4756.20.502.20.1.788ColumnnidPort8RemoteBRemoteLbRemoteBread-onlycurrentNID Series card Detailed Link OAM Status for Port 8: RemoteB: Remote Loopback Support
1.3.6.1.4.1.4756.20.502.20.1.789ColumnnidPort8RemoteBLMRemoteBread-onlycurrentNID Series card Detailed Link OAM Status for Port 8: RemoteB: Link Monitoring Support
1.3.6.1.4.1.4756.20.502.20.1.790ColumnnidPort8RemoteBMIBRetrievalRemoteBread-onlycurrentNID Series card Detailed Link OAM Status for Port 8: RemoteB: MIB Retrieval Support
1.3.6.1.4.1.4756.20.502.20.1.791ColumnnidPort8RemoteBMTUSizeRemoteBread-onlycurrentNID Series card Detailed Link OAM Status for Port 8: RemoteB: MTU Size
1.3.6.1.4.1.4756.20.502.20.1.792ColumnnidPort8RemoteBMultiStateRemoteBread-onlycurrentNID Series card Detailed Link OAM Status for Port 8: RemoteB: Multiplexer State
1.3.6.1.4.1.4756.20.502.20.1.793ColumnnidPort8RemoteBParserStateRemoteBread-onlycurrentNID Series card Detailed Link OAM Status for Port 8: RemoteB: Multiplexer State
1.3.6.1.4.1.4756.20.502.20.1.794ColumnnidPort8RemoteBOUIRemoteBread-onlycurrentNID Series card Detailed Link OAM Status for Port 8: RemoteB: Organizational Unique Identification
1.3.6.1.4.1.4756.20.502.20.1.795ColumnnidPort8RemoteBPDURevRemoteBread-onlycurrentNID Series card Detailed Link OAM Status for Port 8: RemoteB: PDU Revision
1.3.6.1.4.1.4756.20.502.20.1.796ColumnnidPort8PeerModeRemoteBread-onlycurrentNID Series card Detailed Link OAM Status for Port 8: Peer: Mode
1.3.6.1.4.1.4756.20.502.20.1.797ColumnnidPort8PeerUnOperationRemoteBread-onlycurrentNID Series card Detailed Link OAM Status for Port 8: Peer: Unidirectional Operation Support
1.3.6.1.4.1.4756.20.502.20.1.798ColumnnidPort8PeerRemoteLbRemoteBread-onlycurrentNID Series card Detailed Link OAM Status for Port 8: Peer: Remote Loopback Support
1.3.6.1.4.1.4756.20.502.20.1.799ColumnnidPort8PeerLMRemoteBread-onlycurrentNID Series card Detailed Link OAM Status for Port 8: Peer: Link Monitoring Support
1.3.6.1.4.1.4756.20.502.20.1.800ColumnnidPort8PeerMIBRetrievalRemoteBread-onlycurrentNID Series card Detailed Link OAM Status for Port 8: Peer: MIB Retrieval Support
1.3.6.1.4.1.4756.20.502.20.1.801ColumnnidPort8PeerMTUSizeRemoteBread-onlycurrentNID Series card Detailed Link OAM Status for Port 8: Peer: MTU Size
1.3.6.1.4.1.4756.20.502.20.1.802ColumnnidPort8PeerMultiStateRemoteBread-onlycurrentNID Series card Detailed Link OAM Status for Port 8: Peer: Multiplexer State
1.3.6.1.4.1.4756.20.502.20.1.803ColumnnidPort8PeerParserStateRemoteBread-onlycurrentNID Series card Detailed Link OAM Status for Port 8: Peer: Multiplexer State
1.3.6.1.4.1.4756.20.502.20.1.804ColumnnidPort8PeerOUIRemoteBread-onlycurrentNID Series card Detailed Link OAM Status for Port 8: Peer: Organizational Unique Identification
1.3.6.1.4.1.4756.20.502.20.1.805ColumnnidPort8PeerPDURevRemoteBread-onlycurrentNID Series card Detailed Link OAM Status for Port 8: Peer: PDU Revision
1.3.6.1.4.1.4756.20.502.20.1.806ColumnnidLoopProtectionEnableRemoteBread-writecurrentNID Series card Loop Protection Configuration: General Settings - Enable Loop Protection 0: Disable 1: Enable
1.3.6.1.4.1.4756.20.502.20.1.807ColumnnidLoopProtectionTxTimeRemoteBread-writecurrentNID Series card Loop Protection Configuration: General Settings - Transmission Time
1.3.6.1.4.1.4756.20.502.20.1.808ColumnnidLoopProtectionShutdownTimeRemoteBread-writecurrentNID Series card Loop Protection Configuration: General Settings - Shutdown Time
1.3.6.1.4.1.4756.20.502.20.1.809ColumnnidLoopProtectionPort1EnabledRemoteBread-writecurrentNID Series card Loop Protection Configuration for Port 1: Port Configuration - Enable 0: Disable 1: Enable
1.3.6.1.4.1.4756.20.502.20.1.810ColumnnidLoopProtectionPort1ActionRemoteBread-writecurrentNID Series card Loop Protection Configuration for Port 1: Port Configuration - Action 0: Shutdown Port 1: Shutdown Port And Log 2: Log Only
1.3.6.1.4.1.4756.20.502.20.1.811ColumnnidLoopProtectionPort1TxModeRemoteBread-writecurrentNID Series card Loop Protection Configuration for Port 1: Port Configuration - Tx Mode 0: Disable 1: Enable
1.3.6.1.4.1.4756.20.502.20.1.812ColumnnidLoopProtectionPort2EnabledRemoteBread-writecurrentNID Series card Loop Protection Configuration for Port 2: Port Configuration - Enable 0: Disable 1: Enable
1.3.6.1.4.1.4756.20.502.20.1.813ColumnnidLoopProtectionPort2ActionRemoteBread-writecurrentNID Series card Loop Protection Configuration for Port 2: Port Configuration - Action 0: Shutdown Port 1: Shutdown Port And Log 2: Log Only
1.3.6.1.4.1.4756.20.502.20.1.814ColumnnidLoopProtectionPort2TxModeRemoteBread-writecurrentNID Series card Loop Protection Configuration for Port 2: Port Configuration - Tx Mode 0: Disable 1: Enable
1.3.6.1.4.1.4756.20.502.20.1.815ColumnnidLoopProtectionPort3EnabledRemoteBread-writecurrentNID Series card Loop Protection Configuration for Port 3: Port Configuration - Enable 0: Disable 1: Enable
1.3.6.1.4.1.4756.20.502.20.1.816ColumnnidLoopProtectionPort3ActionRemoteBread-writecurrentNID Series card Loop Protection Configuration for Port 3: Port Configuration - Action 0: Shutdown Port 1: Shutdown Port And Log 2: Log Only
1.3.6.1.4.1.4756.20.502.20.1.817ColumnnidLoopProtectionPort3TxModeRemoteBread-writecurrentNID Series card Loop Protection Configuration for Port 3: Port Configuration - Tx Mode 0: Disable 1: Enable
1.3.6.1.4.1.4756.20.502.20.1.818ColumnnidLoopProtectionPort4EnabledRemoteBread-writecurrentNID Series card Loop Protection Configuration for Port 4: Port Configuration - Enable 0: Disable 1: Enable
1.3.6.1.4.1.4756.20.502.20.1.819ColumnnidLoopProtectionPort4ActionRemoteBread-writecurrentNID Series card Loop Protection Configuration for Port 4: Port Configuration - Action 0: Shutdown Port 1: Shutdown Port And Log 2: Log Only
1.3.6.1.4.1.4756.20.502.20.1.820ColumnnidLoopProtectionPort4TxModeRemoteBread-writecurrentNID Series card Loop Protection Configuration for Port 41: Port Configuration - Tx Mode 0: Disable 1: Enable
1.3.6.1.4.1.4756.20.502.20.1.821ColumnnidLoopProtectionPort5EnabledRemoteBread-writecurrentNID Series card Loop Protection Configuration for Port 5: Port Configuration - Enable 0: Disable 1: Enable
1.3.6.1.4.1.4756.20.502.20.1.822ColumnnidLoopProtectionPort5ActionRemoteBread-writecurrentNID Series card Loop Protection Configuration for Port 5: Port Configuration - Action 0: Shutdown Port 1: Shutdown Port And Log 2: Log Only
1.3.6.1.4.1.4756.20.502.20.1.823ColumnnidLoopProtectionPort5TxModeRemoteBread-writecurrentNID Series card Loop Protection Configuration for Port 5: Port Configuration - Tx Mode 0: Disable 1: Enable
1.3.6.1.4.1.4756.20.502.20.1.824ColumnnidLoopProtectionPort6EnabledRemoteBread-writecurrentNID Series card Loop Protection Configuration for Port 6: Port Configuration - Enable 0: Disable 1: Enable
1.3.6.1.4.1.4756.20.502.20.1.825ColumnnidLoopProtectionPort6ActionRemoteBread-writecurrentNID Series card Loop Protection Configuration for Port 6: Port Configuration - Action 0: Shutdown Port 1: Shutdown Port And Log 2: Log Only
1.3.6.1.4.1.4756.20.502.20.1.826ColumnnidLoopProtectionPort6TxModeRemoteBread-writecurrentNID Series card Loop Protection Configuration for Port 6: Port Configuration - Tx Mode 0: Disable 1: Enable
1.3.6.1.4.1.4756.20.502.20.1.827ColumnnidLoopProtectionPort7EnabledRemoteBread-writecurrentNID Series card Loop Protection Configuration for Port 7: Port Configuration - Enable 0: Disable 1: Enable
1.3.6.1.4.1.4756.20.502.20.1.828ColumnnidLoopProtectionPort7ActionRemoteBread-writecurrentNID Series card Loop Protection Configuration for Port 7: Port Configuration - Action 0: Shutdown Port 1: Shutdown Port And Log 2: Log Only
1.3.6.1.4.1.4756.20.502.20.1.829ColumnnidLoopProtectionPort7TxModeRemoteBread-writecurrentNID Series card Loop Protection Configuration for Port 7: Port Configuration - Tx Mode 0: Disable 1: Enable
1.3.6.1.4.1.4756.20.502.20.1.830ColumnnidLoopProtectionPort8EnabledRemoteBread-writecurrentNID Series card Loop Protection Configuration for Port 8: Port Configuration - Enable 0: Disable 1: Enable
1.3.6.1.4.1.4756.20.502.20.1.831ColumnnidLoopProtectionPort8ActionRemoteBread-writecurrentNID Series card Loop Protection Configuration for Port 8: Port Configuration - Action 0: Shutdown Port 1: Shutdown Port And Log 2: Log Only
1.3.6.1.4.1.4756.20.502.20.1.832ColumnnidLoopProtectionPort8TxModeRemoteBread-writecurrentNID Series card Loop Protection Configuration for Port 8: Port Configuration - Tx Mode 0: Disable 1: Enable
1.3.6.1.4.1.4756.20.502.20.1.833ColumnnidLoopProtectionPort1ActionStsRemoteBread-onlycurrentNID Series card Loop Protection Status for Port 1: Action
1.3.6.1.4.1.4756.20.502.20.1.834ColumnnidLoopProtectionPort1TransStsRemoteBread-onlycurrentNID Series card Loop Protection Status for Port 1: Transmit
1.3.6.1.4.1.4756.20.502.20.1.835ColumnnidLoopProtectionPort1LoopsStsRemoteBread-onlycurrentNID Series card Loop Protection Status for Port 1: Loops
1.3.6.1.4.1.4756.20.502.20.1.836ColumnnidLoopProtectionPort1StatusRemoteBread-onlycurrentNID Series card Loop Protection Status for Port 1: Status
1.3.6.1.4.1.4756.20.502.20.1.837ColumnnidLoopProtectionPort1LoopStsRemoteBread-onlycurrentNID Series card Loop Protection Status for Port 1: Loop
1.3.6.1.4.1.4756.20.502.20.1.838ColumnnidLoopProtectionPort1TimeOfLastLoopRemoteBread-onlycurrentNID Series card Loop Protection Status for Port 1: Time of Last Loop
1.3.6.1.4.1.4756.20.502.20.1.839ColumnnidLoopProtectionPort2ActionStsRemoteBread-onlycurrentNID Series card Loop Protection Status for Port 2: Action
1.3.6.1.4.1.4756.20.502.20.1.840ColumnnidLoopProtectionPort2TransStsRemoteBread-onlycurrentNID Series card Loop Protection Status for Port 2: Transmit
1.3.6.1.4.1.4756.20.502.20.1.841ColumnnidLoopProtectionPort2LoopsStsRemoteBread-onlycurrentNID Series card Loop Protection Status for Port 2: Loops
1.3.6.1.4.1.4756.20.502.20.1.842ColumnnidLoopProtectionPort2StatusRemoteBread-onlycurrentNID Series card Loop Protection Status for Port 2: Status
1.3.6.1.4.1.4756.20.502.20.1.843ColumnnidLoopProtectionPort2LoopStsRemoteBread-onlycurrentNID Series card Loop Protection Status for Port 2: Loop
1.3.6.1.4.1.4756.20.502.20.1.844ColumnnidLoopProtectionPort2TimeOfLastLoopRemoteBread-onlycurrentNID Series card Loop Protection Status for Port 2: Time of Last Loop
1.3.6.1.4.1.4756.20.502.20.1.845ColumnnidLoopProtectionPort3ActionStsRemoteBread-onlycurrentNID Series card Loop Protection Status for Port 3: Action
1.3.6.1.4.1.4756.20.502.20.1.846ColumnnidLoopProtectionPort3TransStsRemoteBread-onlycurrentNID Series card Loop Protection Status for Port 3: Transmit
1.3.6.1.4.1.4756.20.502.20.1.847ColumnnidLoopProtectionPort3LoopsStsRemoteBread-onlycurrentNID Series card Loop Protection Status for Port 3: Loops
1.3.6.1.4.1.4756.20.502.20.1.848ColumnnidLoopProtectionPort3StatusRemoteBread-onlycurrentNID Series card Loop Protection Status for Port 3: Status
1.3.6.1.4.1.4756.20.502.20.1.849ColumnnidLoopProtectionPort3LoopStsRemoteBread-onlycurrentNID Series card Loop Protection Status for Port 3: Loop
1.3.6.1.4.1.4756.20.502.20.1.850ColumnnidLoopProtectionPort3TimeOfLastLoopRemoteBread-onlycurrentNID Series card Loop Protection Status for Port 3: Time of Last Loop
1.3.6.1.4.1.4756.20.502.20.1.851ColumnnidLoopProtectionPort4ActionStsRemoteBread-onlycurrentNID Series card Loop Protection Status for Port 4: Action
1.3.6.1.4.1.4756.20.502.20.1.852ColumnnidLoopProtectionPort4TransStsRemoteBread-onlycurrentNID Series card Loop Protection Status for Port 4: Transmit
1.3.6.1.4.1.4756.20.502.20.1.853ColumnnidLoopProtectionPort4LoopsStsRemoteBread-onlycurrentNID Series card Loop Protection Status for Port 4: Loops
1.3.6.1.4.1.4756.20.502.20.1.854ColumnnidLoopProtectionPort4StatusRemoteBread-onlycurrentNID Series card Loop Protection Status for Port 4: Status
1.3.6.1.4.1.4756.20.502.20.1.855ColumnnidLoopProtectionPort4LoopStsRemoteBread-onlycurrentNID Series card Loop Protection Status for Port 4: Loop
1.3.6.1.4.1.4756.20.502.20.1.856ColumnnidLoopProtectionPort4TimeOfLastLoopRemoteBread-onlycurrentNID Series card Loop Protection Status for Port 4: Time of Last Loop
1.3.6.1.4.1.4756.20.502.20.1.857ColumnnidLoopProtectionPort5ActionStsRemoteBread-onlycurrentNID Series card Loop Protection Status for Port 5: Action
1.3.6.1.4.1.4756.20.502.20.1.858ColumnnidLoopProtectionPort5TransStsRemoteBread-onlycurrentNID Series card Loop Protection Status for Port 5: Transmit
1.3.6.1.4.1.4756.20.502.20.1.859ColumnnidLoopProtectionPort5LoopsStsRemoteBread-onlycurrentNID Series card Loop Protection Status for Port 5: Loops
1.3.6.1.4.1.4756.20.502.20.1.860ColumnnidLoopProtectionPort5StatusRemoteBread-onlycurrentNID Series card Loop Protection Status for Port 5: Status
1.3.6.1.4.1.4756.20.502.20.1.861ColumnnidLoopProtectionPort5LoopStsRemoteBread-onlycurrentNID Series card Loop Protection Status for Port 5: Loop
1.3.6.1.4.1.4756.20.502.20.1.862ColumnnidLoopProtectionPort5TimeOfLastLoopRemoteBread-onlycurrentNID Series card Loop Protection Status for Port 5: Time of Last Loop
1.3.6.1.4.1.4756.20.502.20.1.863ColumnnidLoopProtectionPort6ActionStsRemoteBread-onlycurrentNID Series card Loop Protection Status for Port 6: Action
1.3.6.1.4.1.4756.20.502.20.1.864ColumnnidLoopProtectionPort6TransStsRemoteBread-onlycurrentNID Series card Loop Protection Status for Port 6: Transmit
1.3.6.1.4.1.4756.20.502.20.1.865ColumnnidLoopProtectionPort6LoopsStsRemoteBread-onlycurrentNID Series card Loop Protection Status for Port 6: Loops
1.3.6.1.4.1.4756.20.502.20.1.866ColumnnidLoopProtectionPort6StatusRemoteBread-onlycurrentNID Series card Loop Protection Status for Port 64: Status
1.3.6.1.4.1.4756.20.502.20.1.867ColumnnidLoopProtectionPort6LoopStsRemoteBread-onlycurrentNID Series card Loop Protection Status for Port 64: Loop
1.3.6.1.4.1.4756.20.502.20.1.868ColumnnidLoopProtectionPort6TimeOfLastLoopRemoteBread-onlycurrentNID Series card Loop Protection Status for Port 6: Time of Last Loop
1.3.6.1.4.1.4756.20.502.20.1.869ColumnnidLoopProtectionPort7ActionStsRemoteBread-onlycurrentNID Series card Loop Protection Status for Port 7: Action
1.3.6.1.4.1.4756.20.502.20.1.870ColumnnidLoopProtectionPort7TransStsRemoteBread-onlycurrentNID Series card Loop Protection Status for Port 7: Transmit
1.3.6.1.4.1.4756.20.502.20.1.871ColumnnidLoopProtectionPort7LoopsStsRemoteBread-onlycurrentNID Series card Loop Protection Status for Port 7: Loops
1.3.6.1.4.1.4756.20.502.20.1.872ColumnnidLoopProtectionPort7StatusRemoteBread-onlycurrentNID Series card Loop Protection Status for Port 7: Status
1.3.6.1.4.1.4756.20.502.20.1.873ColumnnidLoopProtectionPort7LoopStsRemoteBread-onlycurrentNID Series card Loop Protection Status for Port 7: Loop
1.3.6.1.4.1.4756.20.502.20.1.874ColumnnidLoopProtectionPort7TimeOfLastLoopRemoteBread-onlycurrentNID Series card Loop Protection Status for Port 7: Time of Last Loop
1.3.6.1.4.1.4756.20.502.20.1.875ColumnnidLoopProtectionPort8ActionStsRemoteBread-onlycurrentNID Series card Loop Protection Status for Port 8: Action
1.3.6.1.4.1.4756.20.502.20.1.876ColumnnidLoopProtectionPort8TransStsRemoteBread-onlycurrentNID Series card Loop Protection Status for Port 8: Transmit
1.3.6.1.4.1.4756.20.502.20.1.877ColumnnidLoopProtectionPort8LoopsStsRemoteBread-onlycurrentNID Series card Loop Protection Status for Port 8: Loops
1.3.6.1.4.1.4756.20.502.20.1.878ColumnnidLoopProtectionPort8StatusRemoteBread-onlycurrentNID Series card Loop Protection Status for Port 8: Status
1.3.6.1.4.1.4756.20.502.20.1.879ColumnnidLoopProtectionPort8LoopStsRemoteBread-onlycurrentNID Series card Loop Protection Status for Port 8: Loop
1.3.6.1.4.1.4756.20.502.20.1.880ColumnnidLoopProtectionPort8TimeOfLastLoopRemoteBread-onlycurrentNID Series card Loop Protection Status for Port 8: Time of Last Loop
1.3.6.1.4.1.4756.20.502.20.1.881ColumnniduRingInstanceAddRemoteBread-writecurrentNID Series card Add a new uRing Instance. Syntax: <Instance ID> <ring|sub|chain> <port east> <port west> Instance ID must be either 1 or 2 port east , the valu…
1.3.6.1.4.1.4756.20.502.20.1.882ColumnniduRingInstanceDeleteRemoteBread-writecurrentNID Series card Delete a uRing Instance. Syntax: <uRing Instance>
1.3.6.1.4.1.4756.20.502.20.1.883ColumnniduRingInst1IDRemoteBread-onlycurrentNID Series card u-Ring instance1 ID
1.3.6.1.4.1.4756.20.502.20.1.884ColumnniduRingInst1typeRemoteBread-onlycurrentNID Series card u-Ring instance1 type 0: u-Ring 1: Sub-Ring 2: u-Chain
1.3.6.1.4.1.4756.20.502.20.1.885ColumnniduRingInst1masterRemoteBread-writecurrentNID Series card u-Ring instance1 master 0: No 1: Yes
1.3.6.1.4.1.4756.20.502.20.1.886ColumnniduRingInst1EastPortRemoteBread-onlycurrentNID Series card u-Ring instance1 east port
1.3.6.1.4.1.4756.20.502.20.1.887ColumnniduRingInst1EastEdgeRemoteBread-writecurrentNID Series card u-Ring instance1 east edge 0: No 1: Yes
1.3.6.1.4.1.4756.20.502.20.1.888ColumnniduRingInst1WestPortRemoteBread-onlycurrentNID Series card u-Ring instance1 west port
1.3.6.1.4.1.4756.20.502.20.1.889ColumnniduRingInst1WestEdgeRemoteBread-writecurrentNID Series card u-Ring instance1 west edge 0: No 1: Yes
1.3.6.1.4.1.4756.20.502.20.1.890ColumnniduRingInst2IDRemoteBread-onlycurrentNID Series card u-Ring instance2 ID
1.3.6.1.4.1.4756.20.502.20.1.891ColumnniduRingInst2typeRemoteBread-onlycurrentNID Series card u-Ring instance2 type 0: u-Ring 1: Sub-Ring 2: u-Chain
1.3.6.1.4.1.4756.20.502.20.1.892ColumnniduRingInst2masterRemoteBread-writecurrentNID Series card u-Ring instance2 master 0: No 1: Yes
1.3.6.1.4.1.4756.20.502.20.1.893ColumnniduRingInst2EastPortRemoteBread-onlycurrentNID Series card u-Ring instance2 east port
1.3.6.1.4.1.4756.20.502.20.1.894ColumnniduRingInst2EastEdgeRemoteBread-writecurrentNID Series card u-Ring instance2 east edge 0: No 1: Yes
1.3.6.1.4.1.4756.20.502.20.1.895ColumnniduRingInst2WestPortRemoteBread-onlycurrentNID Series card u-Ring instance2 west port
1.3.6.1.4.1.4756.20.502.20.1.896ColumnniduRingInst2WestEdgeRemoteBread-writecurrentNID Series card u-Ring instance2 west edge 0: No 1: Yes
1.3.6.1.4.1.4756.20.502.20.1.897ColumnniduRingInst3IDRemoteBread-onlycurrentNID Series card u-Ring instance3 ID
1.3.6.1.4.1.4756.20.502.20.1.898ColumnniduRingInst3typeRemoteBread-onlycurrentNID Series card u-Ring instance3 type 0: u-Ring 1: Sub-Ring 2: u-Chain
1.3.6.1.4.1.4756.20.502.20.1.899ColumnniduRingInst3masterRemoteBread-writecurrentNID Series card u-Ring instance3 master 0: No 1: Yes
1.3.6.1.4.1.4756.20.502.20.1.900ColumnniduRingInst3EastPortRemoteBread-onlycurrentNID Series card u-Ring instance3 east port
1.3.6.1.4.1.4756.20.502.20.1.901ColumnniduRingInst3EastEdgeRemoteBread-writecurrentNID Series card u-Ring instance3 east edge 0: No 1: Yes
1.3.6.1.4.1.4756.20.502.20.1.902ColumnniduRingInst3WestPortRemoteBread-onlycurrentNID Series card u-Ring instance3 west port
1.3.6.1.4.1.4756.20.502.20.1.903ColumnniduRingInst3WestEdgeRemoteBread-writecurrentNID Series card u-Ring instance3 west edge 0: No 1: Yes
1.3.6.1.4.1.4756.20.502.20.1.904ColumnniduRingInst4IDRemoteBread-onlycurrentNID Series card u-Ring instance4 ID
1.3.6.1.4.1.4756.20.502.20.1.905ColumnniduRingInst4typeRemoteBread-onlycurrentNID Series card u-Ring instance4 type 0: u-Ring 1: Sub-Ring 2: u-Chain
1.3.6.1.4.1.4756.20.502.20.1.906ColumnniduRingInst4masterRemoteBread-writecurrentNID Series card u-Ring instance4 master 0: No 1: Yes
1.3.6.1.4.1.4756.20.502.20.1.907ColumnniduRingInst4EastPortRemoteBread-onlycurrentNID Series card u-Ring instance4 east port
1.3.6.1.4.1.4756.20.502.20.1.908ColumnniduRingInst4EastEdgeRemoteBread-writecurrentNID Series card u-Ring instance4 east edge 0: No 1: Yes
1.3.6.1.4.1.4756.20.502.20.1.909ColumnniduRingInst4WestPortRemoteBread-onlycurrentNID Series card u-Ring instance4 west port
1.3.6.1.4.1.4756.20.502.20.1.910ColumnniduRingInst4WestEdgeRemoteBread-writecurrentNID Series card u-Ring instance4 west edge 0: No 1: Yes
1.3.6.1.4.1.4756.20.502.20.1.911ColumnniduRingInst1IDstsRemoteBread-onlycurrentNID Series card u-Ring Instance1 ID status
1.3.6.1.4.1.4756.20.502.20.1.912ColumnniduRingInst1typestsRemoteBread-onlycurrentNID Series card u-Ring Type status
1.3.6.1.4.1.4756.20.502.20.1.913ColumnniduRingInst1rolestsRemoteBread-onlycurrentNID Series card u-Ring Role status
1.3.6.1.4.1.4756.20.502.20.1.914ColumnniduRingInst1EastPortstsRemoteBread-onlycurrentNID Series card u-Ring East port status
1.3.6.1.4.1.4756.20.502.20.1.915ColumnniduRingInst1EaststsRemoteBread-onlycurrentNID Series card u-Ring East status
1.3.6.1.4.1.4756.20.502.20.1.916ColumnniduRingInst1EastEdgestsRemoteBread-onlycurrentNID Series card u-Ring East edge status
1.3.6.1.4.1.4756.20.502.20.1.917ColumnniduRingInst1WestPortstsRemoteBread-onlycurrentNID Series card u-Ring West edge status
1.3.6.1.4.1.4756.20.502.20.1.918ColumnniduRingInst1WeststsRemoteBread-onlycurrentNID Series card u-Ring West status
1.3.6.1.4.1.4756.20.502.20.1.919ColumnniduRingInst1WestEdgestsRemoteBread-onlycurrentNID Series card u-Ring West status
1.3.6.1.4.1.4756.20.502.20.1.920ColumnniduRingInst1healthystsRemoteBread-onlycurrentNID Series card u-Ring healthy status None Fine Fault
1.3.6.1.4.1.4756.20.502.20.1.921ColumnniduRingInst2IDstsRemoteBread-onlycurrentNID Series card u-Ring Instance2 ID status
1.3.6.1.4.1.4756.20.502.20.1.922ColumnniduRingInst2typestsRemoteBread-onlycurrentNID Series card u-Ring Type status
1.3.6.1.4.1.4756.20.502.20.1.923ColumnniduRingInst2rolestsRemoteBread-onlycurrentNID Series card u-Ring Role status
1.3.6.1.4.1.4756.20.502.20.1.924ColumnniduRingInst2EastPortstsRemoteBread-onlycurrentNID Series card u-Ring East port status
1.3.6.1.4.1.4756.20.502.20.1.925ColumnniduRingInst2EaststsRemoteBread-onlycurrentNID Series card u-Ring East status
1.3.6.1.4.1.4756.20.502.20.1.926ColumnniduRingInst2EastEdgestsRemoteBread-onlycurrentNID Series card u-Ring East edge status
1.3.6.1.4.1.4756.20.502.20.1.927ColumnniduRingInst2WestPortstsRemoteBread-onlycurrentNID Series card u-Ring West edge status
1.3.6.1.4.1.4756.20.502.20.1.928ColumnniduRingInst2WeststsRemoteBread-onlycurrentNID Series card u-Ring West status
1.3.6.1.4.1.4756.20.502.20.1.929ColumnniduRingInst2WestEdgestsRemoteBread-onlycurrentNID Series card u-Ring West status
1.3.6.1.4.1.4756.20.502.20.1.930ColumnniduRingInst2healthystsRemoteBread-onlycurrentNID Series card u-Ring healthy status None Fine Fault
1.3.6.1.4.1.4756.20.502.20.1.931ColumnniduRingInst3IDstsRemoteBread-onlycurrentNID Series card u-Ring Instance3 ID status
1.3.6.1.4.1.4756.20.502.20.1.932ColumnniduRingInst3typestsRemoteBread-onlycurrentNID Series card u-Ring Type status
1.3.6.1.4.1.4756.20.502.20.1.933ColumnniduRingInst3rolestsRemoteBread-onlycurrentNID Series card u-Ring Role status
1.3.6.1.4.1.4756.20.502.20.1.934ColumnniduRingInst3EastPortstsRemoteBread-onlycurrentNID Series card u-Ring East port status
1.3.6.1.4.1.4756.20.502.20.1.935ColumnniduRingInst3EaststsRemoteBread-onlycurrentNID Series card u-Ring East status
1.3.6.1.4.1.4756.20.502.20.1.936ColumnniduRingInst3EastEdgestsRemoteBread-onlycurrentNID Series card u-Ring East edge status
1.3.6.1.4.1.4756.20.502.20.1.937ColumnniduRingInst3WestPortstsRemoteBread-onlycurrentNID Series card u-Ring West edge status
1.3.6.1.4.1.4756.20.502.20.1.938ColumnniduRingInst3WeststsRemoteBread-onlycurrentNID Series card u-Ring West status
1.3.6.1.4.1.4756.20.502.20.1.939ColumnniduRingInst3WestEdgestsRemoteBread-onlycurrentNID Series card u-Ring West status
1.3.6.1.4.1.4756.20.502.20.1.940ColumnniduRingInst3healthystsRemoteBread-onlycurrentNID Series card u-Ring healthy status None Fine Fault
1.3.6.1.4.1.4756.20.502.20.1.941ColumnniduRingInst4IDstsRemoteBread-onlycurrentNID Series card u-Ring Instance4 ID status
1.3.6.1.4.1.4756.20.502.20.1.942ColumnniduRingInst4typestsRemoteBread-onlycurrentNID Series card u-Ring Type status
1.3.6.1.4.1.4756.20.502.20.1.943ColumnniduRingInst4rolestsRemoteBread-onlycurrentNID Series card u-Ring Role status
1.3.6.1.4.1.4756.20.502.20.1.944ColumnniduRingInst4EastPortstsRemoteBread-onlycurrentNID Series card u-Ring East port status
1.3.6.1.4.1.4756.20.502.20.1.945ColumnniduRingInst4EaststsRemoteBread-onlycurrentNID Series card u-Ring East status
1.3.6.1.4.1.4756.20.502.20.1.946ColumnniduRingInst4EastEdgestsRemoteBread-onlycurrentNID Series card u-Ring East edge status
1.3.6.1.4.1.4756.20.502.20.1.947ColumnniduRingInst4WestPortstsRemoteBread-onlycurrentNID Series card u-Ring West edge status
1.3.6.1.4.1.4756.20.502.20.1.948ColumnniduRingInst4WeststsRemoteBread-onlycurrentNID Series card u-Ring West status
1.3.6.1.4.1.4756.20.502.20.1.949ColumnniduRingInst4WestEdgestsRemoteBread-onlycurrentNID Series card u-Ring West status
1.3.6.1.4.1.4756.20.502.20.1.950ColumnniduRingInst4healthystsRemoteBread-onlycurrentNID Series card u-Ring healthy status None Fine Fault
1.3.6.1.4.1.4756.20.502.20.1.951ColumnnidSTPProtocolVersionRemoteBread-writecurrentNID Series card STP Bridge Configuration: Basic Settings - Protocol Version 0: STP 1: RSTP 2: MSTP
1.3.6.1.4.1.4756.20.502.20.1.952ColumnnidSTPBridgePriorityRemoteBread-writecurrentNID Series card STP Bridge Configuration: Basic Settings - Bridge Priority 0: 0 1: 4096 2: 8192 3: 12288 4: 16384 5: 20480 6: 24576 7: 28672 8: 32768 9: 36864 …
1.3.6.1.4.1.4756.20.502.20.1.953ColumnnidSTPForwardDelayRemoteBread-writecurrentNID Series card STP Bridge Configuration: Basic Settings - Forward Delay
1.3.6.1.4.1.4756.20.502.20.1.954ColumnnidSTPMaxAgeRemoteBread-writecurrentNID Series card STP Bridge Configuration: Basic Settings - Max Age
1.3.6.1.4.1.4756.20.502.20.1.955ColumnnidSTPMaximumHopCountRemoteBread-writecurrentNID Series card STP Bridge Configuration: Basic Settings - Maximum Hop Count
1.3.6.1.4.1.4756.20.502.20.1.956ColumnnidSTPTransmitHoldCountRemoteBread-writecurrentNID Series card STP Bridge Configuration: Basic Settings - Transmit Hold Count
1.3.6.1.4.1.4756.20.502.20.1.957ColumnnidSTPEdgePortBPDUFilteringRemoteBread-writecurrentNID Series card STP Bridge Configuration: Advanced Settings - Edge Port BPDU Filtering 0: Off 1: On
1.3.6.1.4.1.4756.20.502.20.1.958ColumnnidSTPEdgePortBPDUGuardRemoteBread-writecurrentNID Series card STP Bridge Configuration: Advanced Settings - Edge Port BPDU Guard 0: Off 1: On
1.3.6.1.4.1.4756.20.502.20.1.959ColumnnidSTPPortErrorRecoveryTimeoutRemoteBread-writecurrentNID Series card STP Bridge Configuration: Advanced Settings - Port Error Recovery Timeout 0: Off 1: On
1.3.6.1.4.1.4756.20.502.20.1.960ColumnnidMSTIConfigurationNameRemoteBread-writecurrentNID Series card MSTI Configuration: Configuration Identification - Configuration Name
1.3.6.1.4.1.4756.20.502.20.1.961ColumnnidMSTIConfigurationRevisionRemoteBread-writecurrentNID Series card MSTI Configuration: Configuration Identification - Configuration Revision
1.3.6.1.4.1.4756.20.502.20.1.962ColumnnidMSTI1VLANsMappingRemoteBread-writecurrentNID Series card MSTI Configuration: MSTI Mapping - MSTI 1
1.3.6.1.4.1.4756.20.502.20.1.963ColumnnidMSTI2VLANsMappingRemoteBread-writecurrentNID Series card MSTI Configuration: MSTI Mapping - MSTI 2
1.3.6.1.4.1.4756.20.502.20.1.964ColumnnidMSTI3VLANsMappingRemoteBread-writecurrentNID Series card MSTI Configuration: MSTI Mapping - MSTI 3
1.3.6.1.4.1.4756.20.502.20.1.965ColumnnidMSTI4VLANsMappingRemoteBread-writecurrentNID Series card MSTI Configuration: MSTI Mapping - MSTI 4
1.3.6.1.4.1.4756.20.502.20.1.966ColumnnidMSTI5VLANsMappingRemoteBread-writecurrentNID Series card MSTI Configuration: MSTI Mapping - MSTI 5
1.3.6.1.4.1.4756.20.502.20.1.967ColumnnidMSTI6VLANsMappingRemoteBread-writecurrentNID Series card MSTI Configuration: MSTI Mapping - MSTI 6
1.3.6.1.4.1.4756.20.502.20.1.968ColumnnidMSTI7VLANsMappingRemoteBread-writecurrentNID Series card MSTI Configuration: MSTI Mapping - MSTI 7
1.3.6.1.4.1.4756.20.502.20.1.969ColumnnidMSTI8VLANsMappingRemoteBread-writecurrentNID Series card MSTI Configuration: MSTI Mapping - MSTI 8
1.3.6.1.4.1.4756.20.502.20.1.970ColumnnidMSTI9VLANsMappingRemoteBread-writecurrentNID Series card MSTI Configuration: MSTI Mapping - MSTI 9
1.3.6.1.4.1.4756.20.502.20.1.971ColumnnidMSTI10VLANsMappingRemoteBread-writecurrentNID Series card MSTI Configuration: MSTI Mapping - MSTI 10
1.3.6.1.4.1.4756.20.502.20.1.972ColumnnidMSTI11VLANsMappingRemoteBread-writecurrentNID Series card MSTI Configuration: MSTI Mapping - MSTI 11
1.3.6.1.4.1.4756.20.502.20.1.973ColumnnidMSTI12VLANsMappingRemoteBread-writecurrentNID Series card MSTI Configuration: MSTI Mapping - MSTI 12
1.3.6.1.4.1.4756.20.502.20.1.974ColumnnidMSTI13VLANsMappingRemoteBread-writecurrentNID Series card MSTI Configuration: MSTI Mapping - MSTI 13
1.3.6.1.4.1.4756.20.502.20.1.975ColumnnidMSTI14VLANsMappingRemoteBread-writecurrentNID Series card MSTI Configuration: MSTI Mapping - MSTI 14
1.3.6.1.4.1.4756.20.502.20.1.976ColumnnidMSTI15VLANsMappingRemoteBread-writecurrentNID Series card MSTI Configuration: MSTI Mapping - MSTI 15
1.3.6.1.4.1.4756.20.502.20.1.977ColumnnidCISTAggregatedSTPEnabledRemoteBread-writecurrentNID Series card STP CIST Port Configuration: CIST Aggregated Port Configuration - STP Enabled
1.3.6.1.4.1.4756.20.502.20.1.978ColumnnidCISTAggregatedPathCostRemoteBread-writecurrentNID Series card STP CIST Port Configuration: CIST Aggregated Port Configuration - Path Cost Valid values are in the range 0 to 200000000. Setting 0 means Auto …
1.3.6.1.4.1.4756.20.502.20.1.979ColumnnidCISTAggregatedPriorityRemoteBread-writecurrentNID Series card STP CIST Port Configuration: CIST Aggregated Port Configuration - Priority
1.3.6.1.4.1.4756.20.502.20.1.980ColumnnidCISTAggregatedAdminEdgeRemoteBread-writecurrentNID Series card STP CIST Port Configuration: CIST Aggregated Port Configuration - STP Enabled 0: Non-edge 1: Edge
1.3.6.1.4.1.4756.20.502.20.1.981ColumnnidCISTAggregatedAutoEdgeRemoteBread-writecurrentNID Series card STP CIST Port Configuration: CIST Aggregated Port Configuration - Auto Edge 0: Non-edge 1: Edge
1.3.6.1.4.1.4756.20.502.20.1.982ColumnnidCISTAggregatedRestrictedRoleRemoteBread-writecurrentNID Series card STP CIST Port Configuration: CIST Aggregated Port Configuration - Restricted Role 0: Non-edge 1: Edge
1.3.6.1.4.1.4756.20.502.20.1.983ColumnnidCISTAggregatedRestrictedTCNRemoteBread-writecurrentNID Series card STP CIST Port Configuration: CIST Aggregated Port Configuration - Restricted TCN 0: Non-edge 1: Edge
1.3.6.1.4.1.4756.20.502.20.1.984ColumnnidCISTAggregatedBPDUGuardRemoteBread-writecurrentNID Series card STP CIST Port Configuration: CIST Aggregated Port Configuration - BPDU Guard 0: Non-edge 1: Edge
1.3.6.1.4.1.4756.20.502.20.1.985ColumnnidCISTAggregatedPointToPointRemoteBread-writecurrentNID Series card STP CIST Port Configuration: CIST Aggregated Port Configuration - Point-to-point 0: Forced True 1: Forced False 2: Auto
1.3.6.1.4.1.4756.20.502.20.1.986ColumnnidCISTPort1STPEnabledRemoteBread-writecurrentNID Series card STP CIST Port Configuration: CIST Normal Port1 Configuration - STP Enabled
1.3.6.1.4.1.4756.20.502.20.1.987ColumnnidCISTPort1PathCostRemoteBread-writecurrentNID Series card STP CIST Port Configuration: CIST Normal Port1 Configuration - Path Cost Valid values are in the range 0 to 200000000. Setting 0 means Auto pat…
1.3.6.1.4.1.4756.20.502.20.1.988ColumnnidCISTPort1PriorityRemoteBread-writecurrentNID Series card STP CIST Port Configuration: CIST Normal Port1 Configuration - Priority
1.3.6.1.4.1.4756.20.502.20.1.989ColumnnidCISTPort1AdminEdgeRemoteBread-writecurrentNID Series card STP CIST Port Configuration: CIST Normal Port1 Configuration - STP Enabled 0: Non-edge 1: Edge
1.3.6.1.4.1.4756.20.502.20.1.990ColumnnidCISTPort1AutoEdgeRemoteBread-writecurrentNID Series card STP CIST Port Configuration: CIST Normal Port1 Configuration - Auto Edge 0: Non-edge 1: Edge
1.3.6.1.4.1.4756.20.502.20.1.991ColumnnidCISTPort1RestrictedRoleRemoteBread-writecurrentNID Series card STP CIST Port Configuration: CIST Normal Port1 Configuration - Restricted Role 0: Non-edge 1: Edge
1.3.6.1.4.1.4756.20.502.20.1.992ColumnnidCISTPort1RestrictedTCNRemoteBread-writecurrentNID Series card STP CIST Port Configuration: CIST Normal Port1 Configuration - Restricted TCN 0: Non-edge 1: Edge
1.3.6.1.4.1.4756.20.502.20.1.993ColumnnidCISTPort1BPDUGuardRemoteBread-writecurrentNID Series card STP CIST Port Configuration: CIST Normal Port1 Configuration - BPDU Guard 0: Non-edge 1: Edge
1.3.6.1.4.1.4756.20.502.20.1.994ColumnnidCISTPort1PointToPointRemoteBread-writecurrentNID Series card STP CIST Port Configuration: CIST Normal Port1 Configuration - Point-to-point 0: Forced True 1: Forced False 2: Auto
1.3.6.1.4.1.4756.20.502.20.1.995ColumnnidCISTPort2STPEnabledRemoteBread-writecurrentNID Series card STP CIST Port Configuration: CIST Normal Port2 Configuration - STP Enabled
1.3.6.1.4.1.4756.20.502.20.1.996ColumnnidCISTPort2PathCostRemoteBread-writecurrentNID Series card STP CIST Port Configuration: CIST Normal Port2 Configuration - Path Cost Valid values are in the range 0 to 200000000. Setting 0 means Auto pat…
1.3.6.1.4.1.4756.20.502.20.1.997ColumnnidCISTPort2PriorityRemoteBread-writecurrentNID Series card STP CIST Port Configuration: CIST Normal Port2 Configuration - Priority
1.3.6.1.4.1.4756.20.502.20.1.998ColumnnidCISTPort2AdminEdgeRemoteBread-writecurrentNID Series card STP CIST Port Configuration: CIST Normal Port2 Configuration - STP Enabled 0: Non-edge 1: Edge
1.3.6.1.4.1.4756.20.502.20.1.999ColumnnidCISTPort2AutoEdgeRemoteBread-writecurrentNID Series card STP CIST Port Configuration: CIST Normal Port2 Configuration - Auto Edge 0: Non-edge 1: Edge
1.3.6.1.4.1.4756.20.502.20.1.1000ColumnnidCISTPort2RestrictedRoleRemoteBread-writecurrentNID Series card STP CIST Port Configuration: CIST Normal Port2 Configuration - Restricted Role 0: Non-edge 1: Edge
1.3.6.1.4.1.4756.20.502.20.1.1001ColumnnidCISTPort2RestrictedTCNRemoteBread-writecurrentNID Series card STP CIST Port Configuration: CIST Normal Port2 Configuration - Restricted TCN 0: Non-edge 1: Edge
1.3.6.1.4.1.4756.20.502.20.1.1002ColumnnidCISTPort2BPDUGuardRemoteBread-writecurrentNID Series card STP CIST Port Configuration: CIST Normal Port2 Configuration - BPDU Guard 0: Non-edge 1: Edge
1.3.6.1.4.1.4756.20.502.20.1.1003ColumnnidCISTPort2PointToPointRemoteBread-writecurrentNID Series card STP CIST Port Configuration: CIST Normal Port2 Configuration - Point-to-point 0: Forced True 1: Forced False 2: Auto
1.3.6.1.4.1.4756.20.502.20.1.1004ColumnnidCISTPort3STPEnabledRemoteBread-writecurrentNID Series card STP CIST Port Configuration: CIST Normal Port3 Configuration - STP Enabled
1.3.6.1.4.1.4756.20.502.20.1.1005ColumnnidCISTPort3PathCostRemoteBread-writecurrentNID Series card STP CIST Port Configuration: CIST Normal Port3 Configuration - Path Cost Valid values are in the range 0 to 200000000. Setting 0 means Auto pat…
1.3.6.1.4.1.4756.20.502.20.1.1006ColumnnidCISTPort3PriorityRemoteBread-writecurrentNID Series card STP CIST Port Configuration: CIST Normal Port3 Configuration - Priority
1.3.6.1.4.1.4756.20.502.20.1.1007ColumnnidCISTPort3AdminEdgeRemoteBread-writecurrentNID Series card STP CIST Port Configuration: CIST Normal Port3 Configuration - STP Enabled 0: Non-edge 1: Edge
1.3.6.1.4.1.4756.20.502.20.1.1008ColumnnidCISTPort3AutoEdgeRemoteBread-writecurrentNID Series card STP CIST Port Configuration: CIST Normal Port3 Configuration - Auto Edge 0: Non-edge 1: Edge
1.3.6.1.4.1.4756.20.502.20.1.1009ColumnnidCISTPort3RestrictedRoleRemoteBread-writecurrentNID Series card STP CIST Port Configuration: CIST Normal Port3 Configuration - Restricted Role 0: Non-edge 1: Edge
1.3.6.1.4.1.4756.20.502.20.1.1010ColumnnidCISTPort3RestrictedTCNRemoteBread-writecurrentNID Series card STP CIST Port Configuration: CIST Normal Port3 Configuration - Restricted TCN 0: Non-edge 1: Edge
1.3.6.1.4.1.4756.20.502.20.1.1011ColumnnidCISTPort3BPDUGuardRemoteBread-writecurrentNID Series card STP CIST Port Configuration: CIST Normal Port3 Configuration - BPDU Guard 0: Non-edge 1: Edge
1.3.6.1.4.1.4756.20.502.20.1.1012ColumnnidCISTPort3PointToPointRemoteBread-writecurrentNID Series card STP CIST Port Configuration: CIST Normal Port3 Configuration - Point-to-point 0: Forced True 1: Forced False 2: Auto
1.3.6.1.4.1.4756.20.502.20.1.1013ColumnnidCISTPort4STPEnabledRemoteBread-writecurrentNID Series card STP CIST Port Configuration: CIST Normal Port4 Configuration - STP Enabled
1.3.6.1.4.1.4756.20.502.20.1.1014ColumnnidCISTPort4PathCostRemoteBread-writecurrentNID Series card STP CIST Port Configuration: CIST Normal Port4 Configuration - Path Cost Valid values are in the range 0 to 200000000. Setting 0 means Auto pat…
1.3.6.1.4.1.4756.20.502.20.1.1015ColumnnidCISTPort4PriorityRemoteBread-writecurrentNID Series card STP CIST Port Configuration: CIST Normal Port4 Configuration - Priority
1.3.6.1.4.1.4756.20.502.20.1.1016ColumnnidCISTPort4AdminEdgeRemoteBread-writecurrentNID Series card STP CIST Port Configuration: CIST Normal Port4 Configuration - STP Enabled 0: Non-edge 1: Edge
1.3.6.1.4.1.4756.20.502.20.1.1017ColumnnidCISTPort4AutoEdgeRemoteBread-writecurrentNID Series card STP CIST Port Configuration: CIST Normal Port4 Configuration - Auto Edge 0: Non-edge 1: Edge
1.3.6.1.4.1.4756.20.502.20.1.1018ColumnnidCISTPort4RestrictedRoleRemoteBread-writecurrentNID Series card STP CIST Port Configuration: CIST Normal Port4 Configuration - Restricted Role 0: Non-edge 1: Edge
1.3.6.1.4.1.4756.20.502.20.1.1019ColumnnidCISTPort4RestrictedTCNRemoteBread-writecurrentNID Series card STP CIST Port Configuration: CIST Normal Port4 Configuration - Restricted TCN 0: Non-edge 1: Edge
1.3.6.1.4.1.4756.20.502.20.1.1020ColumnnidCISTPort4BPDUGuardRemoteBread-writecurrentNID Series card STP CIST Port Configuration: CIST Normal Port4 Configuration - BPDU Guard 0: Non-edge 1: Edge
1.3.6.1.4.1.4756.20.502.20.1.1021ColumnnidCISTPort4PointToPointRemoteBread-writecurrentNID Series card STP CIST Port Configuration: CIST Normal Port4 Configuration - Point-to-point 0: Forced True 1: Forced False 2: Auto
1.3.6.1.4.1.4756.20.502.20.1.1022ColumnnidCISTPort5STPEnabledRemoteBread-writecurrentNID Series card STP CIST Port Configuration: CIST Normal Port5 Configuration - STP Enabled
1.3.6.1.4.1.4756.20.502.20.1.1023ColumnnidCISTPort5PathCostRemoteBread-writecurrentNID Series card STP CIST Port Configuration: CIST Normal Port5 Configuration - Path Cost Valid values are in the range 0 to 200000000. Setting 0 means Auto pat…
1.3.6.1.4.1.4756.20.502.20.1.1024ColumnnidCISTPort5PriorityRemoteBread-writecurrentNID Series card STP CIST Port Configuration: CIST Normal Port5 Configuration - Priority
1.3.6.1.4.1.4756.20.502.20.1.1025ColumnnidCISTPort5AdminEdgeRemoteBread-writecurrentNID Series card STP CIST Port Configuration: CIST Normal Port5 Configuration - STP Enabled 0: Non-edge 1: Edge
1.3.6.1.4.1.4756.20.502.20.1.1026ColumnnidCISTPort5AutoEdgeRemoteBread-writecurrentNID Series card STP CIST Port Configuration: CIST Normal Port5 Configuration - Auto Edge 0: Non-edge 1: Edge
1.3.6.1.4.1.4756.20.502.20.1.1027ColumnnidCISTPort5RestrictedRoleRemoteBread-writecurrentNID Series card STP CIST Port Configuration: CIST Normal Port5 Configuration - Restricted Role 0: Non-edge 1: Edge
1.3.6.1.4.1.4756.20.502.20.1.1028ColumnnidCISTPort5RestrictedTCNRemoteBread-writecurrentNID Series card STP CIST Port Configuration: CIST Normal Port5 Configuration - Restricted TCN 0: Non-edge 1: Edge
1.3.6.1.4.1.4756.20.502.20.1.1029ColumnnidCISTPort5BPDUGuardRemoteBread-writecurrentNID Series card STP CIST Port Configuration: CIST Normal Port5 Configuration - BPDU Guard 0: Non-edge 1: Edge
1.3.6.1.4.1.4756.20.502.20.1.1030ColumnnidCISTPort5PointToPointRemoteBread-writecurrentNID Series card STP CIST Port Configuration: CIST Normal Port5 Configuration - Point-to-point 0: Forced True 1: Forced False 2: Auto
1.3.6.1.4.1.4756.20.502.20.1.1031ColumnnidCISTPort6STPEnabledRemoteBread-writecurrentNID Series card STP CIST Port Configuration: CIST Normal Port6 Configuration - STP Enabled
1.3.6.1.4.1.4756.20.502.20.1.1032ColumnnidCISTPort6PathCostRemoteBread-writecurrentNID Series card STP CIST Port Configuration: CIST Normal Port6 Configuration - Path Cost Valid values are in the range 0 to 200000000. Setting 0 means Auto pat…
1.3.6.1.4.1.4756.20.502.20.1.1033ColumnnidCISTPort6PriorityRemoteBread-writecurrentNID Series card STP CIST Port Configuration: CIST Normal Port6 Configuration - Priority
1.3.6.1.4.1.4756.20.502.20.1.1034ColumnnidCISTPort6AdminEdgeRemoteBread-writecurrentNID Series card STP CIST Port Configuration: CIST Normal Port6 Configuration - STP Enabled 0: Non-edge 1: Edge
1.3.6.1.4.1.4756.20.502.20.1.1035ColumnnidCISTPort6AutoEdgeRemoteBread-writecurrentNID Series card STP CIST Port Configuration: CIST Normal Port6 Configuration - Auto Edge 0: Non-edge 1: Edge
1.3.6.1.4.1.4756.20.502.20.1.1036ColumnnidCISTPort6RestrictedRoleRemoteBread-writecurrentNID Series card STP CIST Port Configuration: CIST Normal Port6 Configuration - Restricted Role 0: Non-edge 1: Edge
1.3.6.1.4.1.4756.20.502.20.1.1037ColumnnidCISTPort6RestrictedTCNRemoteBread-writecurrentNID Series card STP CIST Port Configuration: CIST Normal Port6 Configuration - Restricted TCN 0: Non-edge 1: Edge
1.3.6.1.4.1.4756.20.502.20.1.1038ColumnnidCISTPort6BPDUGuardRemoteBread-writecurrentNID Series card STP CIST Port Configuration: CIST Normal Port6 Configuration - BPDU Guard 0: Non-edge 1: Edge
1.3.6.1.4.1.4756.20.502.20.1.1039ColumnnidCISTPort6PointToPointRemoteBread-writecurrentNID Series card STP CIST Port Configuration: CIST Normal Port6 Configuration - Point-to-point 0: Forced True 1: Forced False 2: Auto
1.3.6.1.4.1.4756.20.502.20.1.1040ColumnnidCISTPort7STPEnabledRemoteBread-writecurrentNID Series card STP CIST Port Configuration: CIST Normal Port7 Configuration - STP Enabled
1.3.6.1.4.1.4756.20.502.20.1.1041ColumnnidCISTPort7PathCostRemoteBread-writecurrentNID Series card STP CIST Port Configuration: CIST Normal Port7 Configuration - Path Cost Valid values are in the range 0 to 200000000. Setting 0 means Auto pat…
1.3.6.1.4.1.4756.20.502.20.1.1042ColumnnidCISTPort7PriorityRemoteBread-writecurrentNID Series card STP CIST Port Configuration: CIST Normal Port7 Configuration - Priority
1.3.6.1.4.1.4756.20.502.20.1.1043ColumnnidCISTPort7AdminEdgeRemoteBread-writecurrentNID Series card STP CIST Port Configuration: CIST Normal Port7 Configuration - STP Enabled 0: Non-edge 1: Edge
1.3.6.1.4.1.4756.20.502.20.1.1044ColumnnidCISTPort7AutoEdgeRemoteBread-writecurrentNID Series card STP CIST Port Configuration: CIST Normal Port7 Configuration - Auto Edge 0: Non-edge 1: Edge
1.3.6.1.4.1.4756.20.502.20.1.1045ColumnnidCISTPort7RestrictedRoleRemoteBread-writecurrentNID Series card STP CIST Port Configuration: CIST Normal Port7 Configuration - Restricted Role 0: Non-edge 1: Edge
1.3.6.1.4.1.4756.20.502.20.1.1046ColumnnidCISTPort7RestrictedTCNRemoteBread-writecurrentNID Series card STP CIST Port Configuration: CIST Normal Port7 Configuration - Restricted TCN 0: Non-edge 1: Edge
1.3.6.1.4.1.4756.20.502.20.1.1047ColumnnidCISTPort7BPDUGuardRemoteBread-writecurrentNID Series card STP CIST Port Configuration: CIST Normal Port7 Configuration - BPDU Guard 0: Non-edge 1: Edge
1.3.6.1.4.1.4756.20.502.20.1.1048ColumnnidCISTPort7PointToPointRemoteBread-writecurrentNID Series card STP CIST Port Configuration: CIST Normal Port7 Configuration - Point-to-point 0: Forced True 1: Forced False 2: Auto
1.3.6.1.4.1.4756.20.502.20.1.1049ColumnnidCISTPort8STPEnabledRemoteBread-writecurrentNID Series card STP CIST Port Configuration: CIST Normal Port8 Configuration - STP Enabled
1.3.6.1.4.1.4756.20.502.20.1.1050ColumnnidCISTPort8PathCostRemoteBread-writecurrentNID Series card STP CIST Port Configuration: CIST Normal Port8 Configuration - Path Cost Valid values are in the range 0 to 200000000. Setting 0 means Auto pat…
1.3.6.1.4.1.4756.20.502.20.1.1051ColumnnidCISTPort8PriorityRemoteBread-writecurrentNID Series card STP CIST Port Configuration: CIST Normal Port8 Configuration - Priority
1.3.6.1.4.1.4756.20.502.20.1.1052ColumnnidCISTPort8AdminEdgeRemoteBread-writecurrentNID Series card STP CIST Port Configuration: CIST Normal Port8 Configuration - STP Enabled 0: Non-edge 1: Edge
1.3.6.1.4.1.4756.20.502.20.1.1053ColumnnidCISTPort8AutoEdgeRemoteBread-writecurrentNID Series card STP CIST Port Configuration: CIST Normal Port8 Configuration - Auto Edge 0: Non-edge 1: Edge
1.3.6.1.4.1.4756.20.502.20.1.1054ColumnnidCISTPort8RestrictedRoleRemoteBread-writecurrentNID Series card STP CIST Port Configuration: CIST Normal Port8 Configuration - Restricted Role 0: Non-edge 1: Edge
1.3.6.1.4.1.4756.20.502.20.1.1055ColumnnidCISTPort8RestrictedTCNRemoteBread-writecurrentNID Series card STP CIST Port Configuration: CIST Normal Port8 Configuration - Restricted TCN 0: Non-edge 1: Edge
1.3.6.1.4.1.4756.20.502.20.1.1056ColumnnidCISTPort8BPDUGuardRemoteBread-writecurrentNID Series card STP CIST Port Configuration: CIST Normal Port8 Configuration - BPDU Guard 0: Non-edge 1: Edge
1.3.6.1.4.1.4756.20.502.20.1.1057ColumnnidCISTPort8PointToPointRemoteBread-writecurrentNID Series card STP CIST Port Configuration: CIST Normal Port8 Configuration - Point-to-point 0: Forced True 1: Forced False 2: Auto
1.3.6.1.4.1.4756.20.502.20.1.1058ColumnnidMSTI1AggregatedPathCostRemoteBread-writecurrentNID Series card MSTI Port Configuration: MSTI1 Aggregated Ports Configuration - Path Cost Valid values are in the range 0 to 200000000. Setting 0 means Auto pa…
1.3.6.1.4.1.4756.20.502.20.1.1059ColumnnidMSTI1AggregatedPriorityRemoteBread-writecurrentNID Series card MSTI Port Configuration: MSTI1 Aggregated Ports Configuration - Priority
1.3.6.1.4.1.4756.20.502.20.1.1060ColumnnidMSTI1Port1PathCostRemoteBread-writecurrentNID Series card MSTI Port Configuration: MSTI1 Normal Port1 Configuration - Path Cost Valid values are in the range 0 to 200000000. Setting 0 means Auto path c…
1.3.6.1.4.1.4756.20.502.20.1.1061ColumnnidMSTI1Port1PriorityRemoteBread-writecurrentNID Series card MSTI Port Configuration: MSTI1 Normal Port1 Configuration - Priority
1.3.6.1.4.1.4756.20.502.20.1.1062ColumnnidMSTI1Port2PathCostRemoteBread-writecurrentNID Series card MSTI Port Configuration: MSTI1 Normal Port2 Configuration - Path Cost Valid values are in the range 0 to 200000000. Setting 0 means Auto path c…
1.3.6.1.4.1.4756.20.502.20.1.1063ColumnnidMSTI1Port2PriorityRemoteBread-writecurrentNID Series card MSTI Port Configuration: MSTI1 Normal Port2 Configuration - Priority
1.3.6.1.4.1.4756.20.502.20.1.1064ColumnnidMSTI1Port3PathCostRemoteBread-writecurrentNID Series card MSTI Port Configuration: MSTI1 Normal Port3 Configuration - Path Cost Valid values are in the range 0 to 200000000. Setting 0 means Auto path c…
1.3.6.1.4.1.4756.20.502.20.1.1065ColumnnidMSTI1Port3PriorityRemoteBread-writecurrentNID Series card MSTI Port Configuration: MSTI1 Normal Port3 Configuration - Priority
1.3.6.1.4.1.4756.20.502.20.1.1066ColumnnidMSTI1Port4PathCostRemoteBread-writecurrentNID Series card MSTI Port Configuration: MSTI1 Normal Port4 Configuration - Path Cost Valid values are in the range 0 to 200000000. Setting 0 means Auto path c…
1.3.6.1.4.1.4756.20.502.20.1.1067ColumnnidMSTI1Port4PriorityRemoteBread-writecurrentNID Series card MSTI Port Configuration: MSTI1 Normal Port4 Configuration - Priority
1.3.6.1.4.1.4756.20.502.20.1.1068ColumnnidMSTI1Port5PathCostRemoteBread-writecurrentNID Series card MSTI Port Configuration: MSTI1 Normal Port5 Configuration - Path Cost Valid values are in the range 0 to 200000000. Setting 0 means Auto path c…
1.3.6.1.4.1.4756.20.502.20.1.1069ColumnnidMSTI1Port5PriorityRemoteBread-writecurrentNID Series card MSTI Port Configuration: MSTI1 Normal Port5 Configuration - Priority
1.3.6.1.4.1.4756.20.502.20.1.1070ColumnnidMSTI1Port6PathCostRemoteBread-writecurrentNID Series card MSTI Port Configuration: MSTI1 Normal Port6 Configuration - Path Cost Valid values are in the range 0 to 200000000. Setting 0 means Auto path c…
1.3.6.1.4.1.4756.20.502.20.1.1071ColumnnidMSTI1Port6PriorityRemoteBread-writecurrentNID Series card MSTI Port Configuration: MSTI1 Normal Port6 Configuration - Priority
1.3.6.1.4.1.4756.20.502.20.1.1072ColumnnidMSTI1Port7PathCostRemoteBread-writecurrentNID Series card MSTI Port Configuration: MSTI1 Normal Port7 Configuration - Path Cost Valid values are in the range 0 to 200000000. Setting 0 means Auto path c…
1.3.6.1.4.1.4756.20.502.20.1.1073ColumnnidMSTI1Port7PriorityRemoteBread-writecurrentNID Series card MSTI Port Configuration: MSTI1 Normal Port7 Configuration - Priority
1.3.6.1.4.1.4756.20.502.20.1.1074ColumnnidMSTI1Port8PathCostRemoteBread-writecurrentNID Series card MSTI Port Configuration: MSTI1 Normal Port8 Configuration - Path Cost Valid values are in the range 0 to 200000000. Setting 0 means Auto path c…
1.3.6.1.4.1.4756.20.502.20.1.1075ColumnnidMSTI1Port8PriorityRemoteBread-writecurrentNID Series card MSTI Port Configuration: MSTI1 Normal Port8 Configuration - Priority
1.3.6.1.4.1.4756.20.502.20.1.1076ColumnnidMSTI2AggregatedPathCostRemoteBread-writecurrentNID Series card MSTI Port Configuration: MSTI2 Aggregated Ports Configuration - Path Cost Valid values are in the range 0 to 200000000. Setting 0 means Auto pa…
1.3.6.1.4.1.4756.20.502.20.1.1077ColumnnidMSTI2AggregatedPriorityRemoteBread-writecurrentNID Series card MSTI Port Configuration: MSTI2 Aggregated Ports Configuration - Priority
1.3.6.1.4.1.4756.20.502.20.1.1078ColumnnidMSTI2Port1PathCostRemoteBread-writecurrentNID Series card MSTI Port Configuration: MSTI2 Normal Port1 Configuration - Path Cost Valid values are in the range 0 to 200000000. Setting 0 means Auto path c…
1.3.6.1.4.1.4756.20.502.20.1.1079ColumnnidMSTI2Port1PriorityRemoteBread-writecurrentNID Series card MSTI Port Configuration: MSTI2 Normal Port1 Configuration - Priority
1.3.6.1.4.1.4756.20.502.20.1.1080ColumnnidMSTI2Port2PathCostRemoteBread-writecurrentNID Series card MSTI Port Configuration: MSTI2 Normal Port2 Configuration - Path Cost Valid values are in the range 0 to 200000000. Setting 0 means Auto path c…
1.3.6.1.4.1.4756.20.502.20.1.1081ColumnnidMSTI2Port2PriorityRemoteBread-writecurrentNID Series card MSTI Port Configuration: MSTI2 Normal Port2 Configuration - Priority
1.3.6.1.4.1.4756.20.502.20.1.1082ColumnnidMSTI2Port3PathCostRemoteBread-writecurrentNID Series card MSTI Port Configuration: MSTI2 Normal Port3 Configuration - Path Cost Valid values are in the range 0 to 200000000. Setting 0 means Auto path c…
1.3.6.1.4.1.4756.20.502.20.1.1083ColumnnidMSTI2Port3PriorityRemoteBread-writecurrentNID Series card MSTI Port Configuration: MSTI2 Normal Port3 Configuration - Priority
1.3.6.1.4.1.4756.20.502.20.1.1084ColumnnidMSTI2Port4PathCostRemoteBread-writecurrentNID Series card MSTI Port Configuration: MSTI2 Normal Port4 Configuration - Path Cost Valid values are in the range 0 to 200000000. Setting 0 means Auto path c…
1.3.6.1.4.1.4756.20.502.20.1.1085ColumnnidMSTI2Port4PriorityRemoteBread-writecurrentNID Series card MSTI Port Configuration: MSTI2 Normal Port4 Configuration - Priority
1.3.6.1.4.1.4756.20.502.20.1.1086ColumnnidMSTI2Port5PathCostRemoteBread-writecurrentNID Series card MSTI Port Configuration: MSTI2 Normal Port5 Configuration - Path Cost Valid values are in the range 0 to 200000000. Setting 0 means Auto path c…
1.3.6.1.4.1.4756.20.502.20.1.1087ColumnnidMSTI2Port5PriorityRemoteBread-writecurrentNID Series card MSTI Port Configuration: MSTI2 Normal Port5 Configuration - Priority
1.3.6.1.4.1.4756.20.502.20.1.1088ColumnnidMSTI2Port6PathCostRemoteBread-writecurrentNID Series card MSTI Port Configuration: MSTI2 Normal Port6 Configuration - Path Cost Valid values are in the range 0 to 200000000. Setting 0 means Auto path c…
1.3.6.1.4.1.4756.20.502.20.1.1089ColumnnidMSTI2Port6PriorityRemoteBread-writecurrentNID Series card MSTI Port Configuration: MSTI2 Normal Port6 Configuration - Priority
1.3.6.1.4.1.4756.20.502.20.1.1090ColumnnidMSTI2Port7PathCostRemoteBread-writecurrentNID Series card MSTI Port Configuration: MSTI2 Normal Port7 Configuration - Path Cost Valid values are in the range 0 to 200000000. Setting 0 means Auto path c…
1.3.6.1.4.1.4756.20.502.20.1.1091ColumnnidMSTI2Port7PriorityRemoteBread-writecurrentNID Series card MSTI Port Configuration: MSTI2 Normal Port7 Configuration - Priority
1.3.6.1.4.1.4756.20.502.20.1.1092ColumnnidMSTI2Port8PathCostRemoteBread-writecurrentNID Series card MSTI Port Configuration: MSTI2 Normal Port8 Configuration - Path Cost Valid values are in the range 0 to 200000000. Setting 0 means Auto path c…
1.3.6.1.4.1.4756.20.502.20.1.1093ColumnnidMSTI2Port8PriorityRemoteBread-writecurrentNID Series card MSTI Port Configuration: MSTI2 Normal Port8 Configuration - Priority
1.3.6.1.4.1.4756.20.502.20.1.1094ColumnnidMSTI3AggregatedPathCostRemoteBread-writecurrentNID Series card MSTI Port Configuration: MSTI3 Aggregated Ports Configuration - Path Cost Valid values are in the range 0 to 200000000. Setting 0 means Auto pa…
1.3.6.1.4.1.4756.20.502.20.1.1095ColumnnidMSTI3AggregatedPriorityRemoteBread-writecurrentNID Series card MSTI Port Configuration: MSTI3 Aggregated Ports Configuration - Priority
1.3.6.1.4.1.4756.20.502.20.1.1096ColumnnidMSTI3Port1PathCostRemoteBread-writecurrentNID Series card MSTI Port Configuration: MSTI3 Normal Port1 Configuration - Path Cost Valid values are in the range 0 to 200000000. Setting 0 means Auto path c…
1.3.6.1.4.1.4756.20.502.20.1.1097ColumnnidMSTI3Port1PriorityRemoteBread-writecurrentNID Series card MSTI Port Configuration: MSTI3 Normal Port1 Configuration - Priority
1.3.6.1.4.1.4756.20.502.20.1.1098ColumnnidMSTI3Port2PathCostRemoteBread-writecurrentNID Series card MSTI Port Configuration: MSTI3 Normal Port2 Configuration - Path Cost Valid values are in the range 0 to 200000000. Setting 0 means Auto path c…
1.3.6.1.4.1.4756.20.502.20.1.1099ColumnnidMSTI3Port2PriorityRemoteBread-writecurrentNID Series card MSTI Port Configuration: MSTI3 Normal Port2 Configuration - Priority
1.3.6.1.4.1.4756.20.502.20.1.1100ColumnnidMSTI3Port3PathCostRemoteBread-writecurrentNID Series card MSTI Port Configuration: MSTI1 Normal Port3 Configuration - Path Cost Valid values are in the range 0 to 200000000. Setting 0 means Auto path c…
1.3.6.1.4.1.4756.20.502.20.1.1101ColumnnidMSTI3Port3PriorityRemoteBread-writecurrentNID Series card MSTI Port Configuration: MSTI3 Normal Port3 Configuration - Priority
1.3.6.1.4.1.4756.20.502.20.1.1102ColumnnidMSTI3Port4PathCostRemoteBread-writecurrentNID Series card MSTI Port Configuration: MSTI3 Normal Port4 Configuration - Path Cost Valid values are in the range 0 to 200000000. Setting 0 means Auto path c…
1.3.6.1.4.1.4756.20.502.20.1.1103ColumnnidMSTI3Port4PriorityRemoteBread-writecurrentNID Series card MSTI Port Configuration: MSTI3 Normal Port4 Configuration - Priority
1.3.6.1.4.1.4756.20.502.20.1.1104ColumnnidMSTI3Port5PathCostRemoteBread-writecurrentNID Series card MSTI Port Configuration: MSTI3 Normal Port5 Configuration - Path Cost Valid values are in the range 0 to 200000000. Setting 0 means Auto path c…
1.3.6.1.4.1.4756.20.502.20.1.1105ColumnnidMSTI3Port5PriorityRemoteBread-writecurrentNID Series card MSTI Port Configuration: MSTI3 Normal Port5 Configuration - Priority
1.3.6.1.4.1.4756.20.502.20.1.1106ColumnnidMSTI3Port6PathCostRemoteBread-writecurrentNID Series card MSTI Port Configuration: MSTI3 Normal Port6 Configuration - Path Cost Valid values are in the range 0 to 200000000. Setting 0 means Auto path c…
1.3.6.1.4.1.4756.20.502.20.1.1107ColumnnidMSTI3Port6PriorityRemoteBread-writecurrentNID Series card MSTI Port Configuration: MSTI3 Normal Port6 Configuration - Priority
1.3.6.1.4.1.4756.20.502.20.1.1108ColumnnidMSTI3Port7PathCostRemoteBread-writecurrentNID Series card MSTI Port Configuration: MSTI3 Normal Port7 Configuration - Path Cost Valid values are in the range 0 to 200000000. Setting 0 means Auto path c…
1.3.6.1.4.1.4756.20.502.20.1.1109ColumnnidMSTI3Port7PriorityRemoteBread-writecurrentNID Series card MSTI Port Configuration: MSTI3 Normal Port7 Configuration - Priority
1.3.6.1.4.1.4756.20.502.20.1.1110ColumnnidMSTI3Port8PathCostRemoteBread-writecurrentNID Series card MSTI Port Configuration: MSTI3 Normal Port8 Configuration - Path Cost Valid values are in the range 0 to 200000000. Setting 0 means Auto path c…
1.3.6.1.4.1.4756.20.502.20.1.1111ColumnnidMSTI3Port8PriorityRemoteBread-writecurrentNID Series card MSTI Port Configuration: MSTI3 Normal Port8 Configuration - Priority
1.3.6.1.4.1.4756.20.502.20.1.1112ColumnnidMSTI4AggregatedPathCostRemoteBread-writecurrentNID Series card MSTI Port Configuration: MSTI4 Aggregated Ports Configuration - Path Cost Valid values are in the range 0 to 200000000. Setting 0 means Auto pa…
1.3.6.1.4.1.4756.20.502.20.1.1113ColumnnidMSTI4AggregatedPriorityRemoteBread-writecurrentNID Series card MSTI Port Configuration: MSTI4 Aggregated Ports Configuration - Priority
1.3.6.1.4.1.4756.20.502.20.1.1114ColumnnidMSTI4Port1PathCostRemoteBread-writecurrentNID Series card MSTI Port Configuration: MSTI4 Normal Port1 Configuration - Path Cost Valid values are in the range 0 to 200000000. Setting 0 means Auto path c…
1.3.6.1.4.1.4756.20.502.20.1.1115ColumnnidMSTI4Port1PriorityRemoteBread-writecurrentNID Series card MSTI Port Configuration: MSTI4 Normal Port1 Configuration - Priority
1.3.6.1.4.1.4756.20.502.20.1.1116ColumnnidMSTI4Port2PathCostRemoteBread-writecurrentNID Series card MSTI Port Configuration: MSTI4 Normal Port2 Configuration - Path Cost Valid values are in the range 0 to 200000000. Setting 0 means Auto path c…
1.3.6.1.4.1.4756.20.502.20.1.1117ColumnnidMSTI4Port2PriorityRemoteBread-writecurrentNID Series card MSTI Port Configuration: MSTI4 Normal Port2 Configuration - Priority
1.3.6.1.4.1.4756.20.502.20.1.1118ColumnnidMSTI4Port3PathCostRemoteBread-writecurrentNID Series card MSTI Port Configuration: MSTI1 Normal Port3 Configuration - Path Cost Valid values are in the range 0 to 200000000. Setting 0 means Auto path c…
1.3.6.1.4.1.4756.20.502.20.1.1119ColumnnidMSTI4Port3PriorityRemoteBread-writecurrentNID Series card MSTI Port Configuration: MSTI4 Normal Port3 Configuration - Priority
1.3.6.1.4.1.4756.20.502.20.1.1120ColumnnidMSTI4Port4PathCostRemoteBread-writecurrentNID Series card MSTI Port Configuration: MSTI4 Normal Port4 Configuration - Path Cost Valid values are in the range 0 to 200000000. Setting 0 means Auto path c…
1.3.6.1.4.1.4756.20.502.20.1.1121ColumnnidMSTI4Port4PriorityRemoteBread-writecurrentNID Series card MSTI Port Configuration: MSTI4 Normal Port4 Configuration - Priority
1.3.6.1.4.1.4756.20.502.20.1.1122ColumnnidMSTI4Port5PathCostRemoteBread-writecurrentNID Series card MSTI Port Configuration: MSTI4 Normal Port5 Configuration - Path Cost Valid values are in the range 0 to 200000000. Setting 0 means Auto path c…
1.3.6.1.4.1.4756.20.502.20.1.1123ColumnnidMSTI4Port5PriorityRemoteBread-writecurrentNID Series card MSTI Port Configuration: MSTI4 Normal Port5 Configuration - Priority
1.3.6.1.4.1.4756.20.502.20.1.1124ColumnnidMSTI4Port6PathCostRemoteBread-writecurrentNID Series card MSTI Port Configuration: MSTI4 Normal Port4 Configuration - Path Cost Valid values are in the range 0 to 200000000. Setting 0 means Auto path c…
1.3.6.1.4.1.4756.20.502.20.1.1125ColumnnidMSTI4Port6PriorityRemoteBread-writecurrentNID Series card MSTI Port Configuration: MSTI4 Normal Port6 Configuration - Priority
1.3.6.1.4.1.4756.20.502.20.1.1126ColumnnidMSTI4Port7PathCostRemoteBread-writecurrentNID Series card MSTI Port Configuration: MSTI4 Normal Port7 Configuration - Path Cost Valid values are in the range 0 to 200000000. Setting 0 means Auto path c…
1.3.6.1.4.1.4756.20.502.20.1.1127ColumnnidMSTI4Port7PriorityRemoteBread-writecurrentNID Series card MSTI Port Configuration: MSTI4 Normal Port7 Configuration - Priority
1.3.6.1.4.1.4756.20.502.20.1.1128ColumnnidMSTI4Port8PathCostRemoteBread-writecurrentNID Series card MSTI Port Configuration: MSTI4 Normal Port8 Configuration - Path Cost Valid values are in the range 0 to 200000000. Setting 0 means Auto path c…
1.3.6.1.4.1.4756.20.502.20.1.1129ColumnnidMSTI4Port8PriorityRemoteBread-writecurrentNID Series card MSTI Port Configuration: MSTI4 Normal Port8 Configuration - Priority
1.3.6.1.4.1.4756.20.502.20.1.1130ColumnnidMSTI5AggregatedPathCostRemoteBread-writecurrentNID Series card MSTI Port Configuration: MSTI5 Aggregated Ports Configuration - Path Cost Valid values are in the range 0 to 200000000. Setting 0 means Auto pa…
1.3.6.1.4.1.4756.20.502.20.1.1131ColumnnidMSTI5AggregatedPriorityRemoteBread-writecurrentNID Series card MSTI Port Configuration: MSTI5 Aggregated Ports Configuration - Priority
1.3.6.1.4.1.4756.20.502.20.1.1132ColumnnidMSTI5Port1PathCostRemoteBread-writecurrentNID Series card MSTI Port Configuration: MSTI5 Normal Port1 Configuration - Path Cost Valid values are in the range 0 to 200000000. Setting 0 means Auto path c…
1.3.6.1.4.1.4756.20.502.20.1.1133ColumnnidMSTI5Port1PriorityRemoteBread-writecurrentNID Series card MSTI Port Configuration: MSTI5 Normal Port1 Configuration - Priority
1.3.6.1.4.1.4756.20.502.20.1.1134ColumnnidMSTI5Port2PathCostRemoteBread-writecurrentNID Series card MSTI Port Configuration: MSTI5 Normal Port2 Configuration - Path Cost Valid values are in the range 0 to 200000000. Setting 0 means Auto path c…
1.3.6.1.4.1.4756.20.502.20.1.1135ColumnnidMSTI5Port2PriorityRemoteBread-writecurrentNID Series card MSTI Port Configuration: MSTI5 Normal Port2 Configuration - Priority
1.3.6.1.4.1.4756.20.502.20.1.1136ColumnnidMSTI5Port3PathCostRemoteBread-writecurrentNID Series card MSTI Port Configuration: MSTI5 Normal Port3 Configuration - Path Cost Valid values are in the range 0 to 200000000. Setting 0 means Auto path c…
1.3.6.1.4.1.4756.20.502.20.1.1137ColumnnidMSTI5Port3PriorityRemoteBread-writecurrentNID Series card MSTI Port Configuration: MSTI5 Normal Port3 Configuration - Priority
1.3.6.1.4.1.4756.20.502.20.1.1138ColumnnidMSTI5Port4PathCostRemoteBread-writecurrentNID Series card MSTI Port Configuration: MSTI5 Normal Port4 Configuration - Path Cost Valid values are in the range 0 to 200000000. Setting 0 means Auto path c…
1.3.6.1.4.1.4756.20.502.20.1.1139ColumnnidMSTI5Port4PriorityRemoteBread-writecurrentNID Series card MSTI Port Configuration: MSTI5 Normal Port4 Configuration - Priority
1.3.6.1.4.1.4756.20.502.20.1.1140ColumnnidMSTI5Port5PathCostRemoteBread-writecurrentNID Series card MSTI Port Configuration: MSTI5 Normal Port5 Configuration - Path Cost Valid values are in the range 0 to 200000000. Setting 0 means Auto path c…
1.3.6.1.4.1.4756.20.502.20.1.1141ColumnnidMSTI5Port5PriorityRemoteBread-writecurrentNID Series card MSTI Port Configuration: MSTI5 Normal Port5 Configuration - Priority
1.3.6.1.4.1.4756.20.502.20.1.1142ColumnnidMSTI5Port6PathCostRemoteBread-writecurrentNID Series card MSTI Port Configuration: MSTI5 Normal Port6 Configuration - Path Cost Valid values are in the range 0 to 200000000. Setting 0 means Auto path c…
1.3.6.1.4.1.4756.20.502.20.1.1143ColumnnidMSTI5Port6PriorityRemoteBread-writecurrentNID Series card MSTI Port Configuration: MSTI5 Normal Port6 Configuration - Priority
1.3.6.1.4.1.4756.20.502.20.1.1144ColumnnidMSTI5Port7PathCostRemoteBread-writecurrentNID Series card MSTI Port Configuration: MSTI5 Normal Port7 Configuration - Path Cost Valid values are in the range 0 to 200000000. Setting 0 means Auto path c…
1.3.6.1.4.1.4756.20.502.20.1.1145ColumnnidMSTI5Port7PriorityRemoteBread-writecurrentNID Series card MSTI Port Configuration: MSTI5 Normal Port7 Configuration - Priority
1.3.6.1.4.1.4756.20.502.20.1.1146ColumnnidMSTI5Port8PathCostRemoteBread-writecurrentNID Series card MSTI Port Configuration: MSTI5 Normal Port8 Configuration - Path Cost Valid values are in the range 0 to 200000000. Setting 0 means Auto path c…
1.3.6.1.4.1.4756.20.502.20.1.1147ColumnnidMSTI5Port8PriorityRemoteBread-writecurrentNID Series card MSTI Port Configuration: MSTI5 Normal Port8 Configuration - Priority
1.3.6.1.4.1.4756.20.502.20.1.1148ColumnnidMSTI6AggregatedPathCostRemoteBread-writecurrentNID Series card MSTI Port Configuration: MSTI6 Aggregated Ports Configuration - Path Cost Valid values are in the range 0 to 200000000. Setting 0 means Auto pa…
1.3.6.1.4.1.4756.20.502.20.1.1149ColumnnidMSTI6AggregatedPriorityRemoteBread-writecurrentNID Series card MSTI Port Configuration: MSTI6 Aggregated Ports Configuration - Priority
1.3.6.1.4.1.4756.20.502.20.1.1150ColumnnidMSTI6Port1PathCostRemoteBread-writecurrentNID Series card MSTI Port Configuration: MSTI6 Normal Port1 Configuration - Path Cost Valid values are in the range 0 to 200000000. Setting 0 means Auto path c…
1.3.6.1.4.1.4756.20.502.20.1.1151ColumnnidMSTI6Port1PriorityRemoteBread-writecurrentNID Series card MSTI Port Configuration: MSTI6 Normal Port1 Configuration - Priority
1.3.6.1.4.1.4756.20.502.20.1.1152ColumnnidMSTI6Port2PathCostRemoteBread-writecurrentNID Series card MSTI Port Configuration: MSTI6 Normal Port2 Configuration - Path Cost Valid values are in the range 0 to 200000000. Setting 0 means Auto path c…
1.3.6.1.4.1.4756.20.502.20.1.1153ColumnnidMSTI6Port2PriorityRemoteBread-writecurrentNID Series card MSTI Port Configuration: MSTI6 Normal Port2 Configuration - Priority
1.3.6.1.4.1.4756.20.502.20.1.1154ColumnnidMSTI6Port3PathCostRemoteBread-writecurrentNID Series card MSTI Port Configuration: MSTI6 Normal Port3 Configuration - Path Cost Valid values are in the range 0 to 200000000. Setting 0 means Auto path c…
1.3.6.1.4.1.4756.20.502.20.1.1155ColumnnidMSTI6Port3PriorityRemoteBread-writecurrentNID Series card MSTI Port Configuration: MSTI6 Normal Port3 Configuration - Priority
1.3.6.1.4.1.4756.20.502.20.1.1156ColumnnidMSTI6Port4PathCostRemoteBread-writecurrentNID Series card MSTI Port Configuration: MSTI6 Normal Port4 Configuration - Path Cost Valid values are in the range 0 to 200000000. Setting 0 means Auto path c…
1.3.6.1.4.1.4756.20.502.20.1.1157ColumnnidMSTI6Port4PriorityRemoteBread-writecurrentNID Series card MSTI Port Configuration: MSTI6 Normal Port4 Configuration - Priority
1.3.6.1.4.1.4756.20.502.20.1.1158ColumnnidMSTI6Port5PathCostRemoteBread-writecurrentNID Series card MSTI Port Configuration: MSTI6 Normal Port5 Configuration - Path Cost Valid values are in the range 0 to 200000000. Setting 0 means Auto path c…
1.3.6.1.4.1.4756.20.502.20.1.1159ColumnnidMSTI6Port5PriorityRemoteBread-writecurrentNID Series card MSTI Port Configuration: MSTI6 Normal Port6 Configuration - Priority
1.3.6.1.4.1.4756.20.502.20.1.1160ColumnnidMSTI6Port6PathCostRemoteBread-writecurrentNID Series card MSTI Port Configuration: MSTI6 Normal Port6 Configuration - Path Cost Valid values are in the range 0 to 200000000. Setting 0 means Auto path c…
1.3.6.1.4.1.4756.20.502.20.1.1161ColumnnidMSTI6Port6PriorityRemoteBread-writecurrentNID Series card MSTI Port Configuration: MSTI6 Normal Port6 Configuration - Priority
1.3.6.1.4.1.4756.20.502.20.1.1162ColumnnidMSTI6Port7PathCostRemoteBread-writecurrentNID Series card MSTI Port Configuration: MSTI6 Normal Port7 Configuration - Path Cost Valid values are in the range 0 to 200000000. Setting 0 means Auto path c…
1.3.6.1.4.1.4756.20.502.20.1.1163ColumnnidMSTI6Port7PriorityRemoteBread-writecurrentNID Series card MSTI Port Configuration: MSTI6 Normal Port6 Configuration - Priority
1.3.6.1.4.1.4756.20.502.20.1.1164ColumnnidMSTI6Port8PathCostRemoteBread-writecurrentNID Series card MSTI Port Configuration: MSTI6 Normal Port8 Configuration - Path Cost Valid values are in the range 0 to 200000000. Setting 0 means Auto path c…
1.3.6.1.4.1.4756.20.502.20.1.1165ColumnnidMSTI6Port8PriorityRemoteBread-writecurrentNID Series card MSTI Port Configuration: MSTI6 Normal Port8 Configuration - Priority
1.3.6.1.4.1.4756.20.502.20.1.1166ColumnnidMSTI7AggregatedPathCostRemoteBread-writecurrentNID Series card MSTI Port Configuration: MSTI7 Aggregated Ports Configuration - Path Cost Valid values are in the range 0 to 200000000. Setting 0 means Auto pa…
1.3.6.1.4.1.4756.20.502.20.1.1167ColumnnidMSTI7AggregatedPriorityRemoteBread-writecurrentNID Series card MSTI Port Configuration: MSTI7 Aggregated Ports Configuration - Priority
1.3.6.1.4.1.4756.20.502.20.1.1168ColumnnidMSTI7Port1PathCostRemoteBread-writecurrentNID Series card MSTI Port Configuration: MSTI1 Normal Port1 Configuration - Path Cost Valid values are in the range 0 to 200000000. Setting 0 means Auto path c…
1.3.6.1.4.1.4756.20.502.20.1.1169ColumnnidMSTI7Port1PriorityRemoteBread-writecurrentNID Series card MSTI Port Configuration: MSTI1 Normal Port1 Configuration - Priority
1.3.6.1.4.1.4756.20.502.20.1.1170ColumnnidMSTI7Port2PathCostRemoteBread-writecurrentNID Series card MSTI Port Configuration: MSTI7 Normal Port2 Configuration - Path Cost Valid values are in the range 0 to 200000000. Setting 0 means Auto path c…
1.3.6.1.4.1.4756.20.502.20.1.1171ColumnnidMSTI7Port2PriorityRemoteBread-writecurrentNID Series card MSTI Port Configuration: MSTI7 Normal Port2 Configuration - Priority
1.3.6.1.4.1.4756.20.502.20.1.1172ColumnnidMSTI7Port3PathCostRemoteBread-writecurrentNID Series card MSTI Port Configuration: MSTI7 Normal Port3 Configuration - Path Cost Valid values are in the range 0 to 200000000. Setting 0 means Auto path c…
1.3.6.1.4.1.4756.20.502.20.1.1173ColumnnidMSTI7Port3PriorityRemoteBread-writecurrentNID Series card MSTI Port Configuration: MSTI7 Normal Port3 Configuration - Priority
1.3.6.1.4.1.4756.20.502.20.1.1174ColumnnidMSTI7Port4PathCostRemoteBread-writecurrentNID Series card MSTI Port Configuration: MSTI7 Normal Port4 Configuration - Path Cost Valid values are in the range 0 to 200000000. Setting 0 means Auto path c…
1.3.6.1.4.1.4756.20.502.20.1.1175ColumnnidMSTI7Port4PriorityRemoteBread-writecurrentNID Series card MSTI Port Configuration: MSTI7 Normal Port4 Configuration - Priority
1.3.6.1.4.1.4756.20.502.20.1.1176ColumnnidMSTI7Port5PathCostRemoteBread-writecurrentNID Series card MSTI Port Configuration: MSTI7 Normal Port5 Configuration - Path Cost Valid values are in the range 0 to 200000000. Setting 0 means Auto path c…
1.3.6.1.4.1.4756.20.502.20.1.1177ColumnnidMSTI7Port5PriorityRemoteBread-writecurrentNID Series card MSTI Port Configuration: MSTI7 Normal Port5 Configuration - Priority
1.3.6.1.4.1.4756.20.502.20.1.1178ColumnnidMSTI7Port6PathCostRemoteBread-writecurrentNID Series card MSTI Port Configuration: MSTI7 Normal Port6 Configuration - Path Cost Valid values are in the range 0 to 200000000. Setting 0 means Auto path c…
1.3.6.1.4.1.4756.20.502.20.1.1179ColumnnidMSTI7Port6PriorityRemoteBread-writecurrentNID Series card MSTI Port Configuration: MSTI7 Normal Port6 Configuration - Priority
1.3.6.1.4.1.4756.20.502.20.1.1180ColumnnidMSTI7Port7PathCostRemoteBread-writecurrentNID Series card MSTI Port Configuration: MSTI7 Normal Port7 Configuration - Path Cost Valid values are in the range 0 to 200000000. Setting 0 means Auto path c…
1.3.6.1.4.1.4756.20.502.20.1.1181ColumnnidMSTI7Port7PriorityRemoteBread-writecurrentNID Series card MSTI Port Configuration: MSTI7 Normal Port7 Configuration - Priority
1.3.6.1.4.1.4756.20.502.20.1.1182ColumnnidMSTI7Port8PathCostRemoteBread-writecurrentNID Series card MSTI Port Configuration: MSTI7 Normal Port8 Configuration - Path Cost Valid values are in the range 0 to 200000000. Setting 0 means Auto path c…
1.3.6.1.4.1.4756.20.502.20.1.1183ColumnnidMSTI7Port8PriorityRemoteBread-writecurrentNID Series card MSTI Port Configuration: MSTI7 Normal Port8 Configuration - Priority
1.3.6.1.4.1.4756.20.502.20.1.1184ColumnnidMSTI8AggregatedPathCostRemoteBread-writecurrentNID Series card MSTI Port Configuration: MSTI8 Aggregated Ports Configuration - Path Cost Valid values are in the range 0 to 200000000. Setting 0 means Auto pa…
1.3.6.1.4.1.4756.20.502.20.1.1185ColumnnidMSTI8AggregatedPriorityRemoteBread-writecurrentNID Series card MSTI Port Configuration: MSTI7 Aggregated Ports Configuration - Priority
1.3.6.1.4.1.4756.20.502.20.1.1186ColumnnidMSTI8Port1PathCostRemoteBread-writecurrentNID Series card MSTI Port Configuration: MSTI8 Normal Port1 Configuration - Path Cost Valid values are in the range 0 to 200000000. Setting 0 means Auto path c…
1.3.6.1.4.1.4756.20.502.20.1.1187ColumnnidMSTI8Port1PriorityRemoteBread-writecurrentNID Series card MSTI Port Configuration: MSTI8 Normal Port1 Configuration - Priority
1.3.6.1.4.1.4756.20.502.20.1.1188ColumnnidMSTI8Port2PathCostRemoteBread-writecurrentNID Series card MSTI Port Configuration: MSTI8 Normal Port2 Configuration - Path Cost Valid values are in the range 0 to 200000000. Setting 0 means Auto path c…
1.3.6.1.4.1.4756.20.502.20.1.1189ColumnnidMSTI8Port2PriorityRemoteBread-writecurrentNID Series card MSTI Port Configuration: MSTI8 Normal Port2 Configuration - Priority
1.3.6.1.4.1.4756.20.502.20.1.1190ColumnnidMSTI8Port3PathCostRemoteBread-writecurrentNID Series card MSTI Port Configuration: MSTI8 Normal Port3 Configuration - Path Cost Valid values are in the range 0 to 200000000. Setting 0 means Auto path c…
1.3.6.1.4.1.4756.20.502.20.1.1191ColumnnidMSTI8Port3PriorityRemoteBread-writecurrentNID Series card MSTI Port Configuration: MSTI8 Normal Port3 Configuration - Priority
1.3.6.1.4.1.4756.20.502.20.1.1192ColumnnidMSTI8Port4PathCostRemoteBread-writecurrentNID Series card MSTI Port Configuration: MSTI8 Normal Port4 Configuration - Path Cost Valid values are in the range 0 to 200000000. Setting 0 means Auto path c…
1.3.6.1.4.1.4756.20.502.20.1.1193ColumnnidMSTI8Port4PriorityRemoteBread-writecurrentNID Series card MSTI Port Configuration: MSTI8 Normal Port4 Configuration - Priority
1.3.6.1.4.1.4756.20.502.20.1.1194ColumnnidMSTI8Port5PathCostRemoteBread-writecurrentNID Series card MSTI Port Configuration: MSTI8 Normal Port5 Configuration - Path Cost Valid values are in the range 0 to 200000000. Setting 0 means Auto path c…
1.3.6.1.4.1.4756.20.502.20.1.1195ColumnnidMSTI8Port5PriorityRemoteBread-writecurrentNID Series card MSTI Port Configuration: MSTI8 Normal Port5 Configuration - Priority
1.3.6.1.4.1.4756.20.502.20.1.1196ColumnnidMSTI8Port6PathCostRemoteBread-writecurrentNID Series card MSTI Port Configuration: MSTI8 Normal Port6 Configuration - Path Cost Valid values are in the range 0 to 200000000. Setting 0 means Auto path c…
1.3.6.1.4.1.4756.20.502.20.1.1197ColumnnidMSTI8Port6PriorityRemoteBread-writecurrentNID Series card MSTI Port Configuration: MSTI8 Normal Port6 Configuration - Priority
1.3.6.1.4.1.4756.20.502.20.1.1198ColumnnidMSTI8Port7PathCostRemoteBread-writecurrentNID Series card MSTI Port Configuration: MSTI8 Normal Port7 Configuration - Path Cost Valid values are in the range 0 to 200000000. Setting 0 means Auto path c…
1.3.6.1.4.1.4756.20.502.20.1.1199ColumnnidMSTI8Port7PriorityRemoteBread-writecurrentNID Series card MSTI Port Configuration: MSTI8 Normal Port7 Configuration - Priority
1.3.6.1.4.1.4756.20.502.20.1.1200ColumnnidMSTI8Port8PathCostRemoteBread-writecurrentNID Series card MSTI Port Configuration: MSTI7 Normal Port8 Configuration - Path Cost Valid values are in the range 0 to 200000000. Setting 0 means Auto path c…
1.3.6.1.4.1.4756.20.502.20.1.1201ColumnnidMSTI8Port8PriorityRemoteBread-writecurrentNID Series card MSTI Port Configuration: MSTI8 Normal Port8 Configuration - Priority
1.3.6.1.4.1.4756.20.502.20.1.1202ColumnnidMSTI9AggregatedPathCostRemoteBread-writecurrentNID Series card MSTI Port Configuration: MSTI9 Aggregated Ports Configuration - Path Cost Valid values are in the range 0 to 200000000. Setting 0 means Auto pa…
1.3.6.1.4.1.4756.20.502.20.1.1203ColumnnidMSTI9AggregatedPriorityRemoteBread-writecurrentNID Series card MSTI Port Configuration: MSTI9 Aggregated Ports Configuration - Priority
1.3.6.1.4.1.4756.20.502.20.1.1204ColumnnidMSTI9Port1PathCostRemoteBread-writecurrentNID Series card MSTI Port Configuration: MSTI9 Normal Port1 Configuration - Path Cost Valid values are in the range 0 to 200000000. Setting 0 means Auto path c…
1.3.6.1.4.1.4756.20.502.20.1.1205ColumnnidMSTI9Port1PriorityRemoteBread-writecurrentNID Series card MSTI Port Configuration: MSTI9 Normal Port1 Configuration - Priority
1.3.6.1.4.1.4756.20.502.20.1.1206ColumnnidMSTI9Port2PathCostRemoteBread-writecurrentNID Series card MSTI Port Configuration: MSTI9 Normal Port2 Configuration - Path Cost Valid values are in the range 0 to 200000000. Setting 0 means Auto path c…
1.3.6.1.4.1.4756.20.502.20.1.1207ColumnnidMSTI9Port2PriorityRemoteBread-writecurrentNID Series card MSTI Port Configuration: MSTI8 Normal Port2 Configuration - Priority
1.3.6.1.4.1.4756.20.502.20.1.1208ColumnnidMSTI9Port3PathCostRemoteBread-writecurrentNID Series card MSTI Port Configuration: MSTI8 Normal Port3 Configuration - Path Cost Valid values are in the range 0 to 200000000. Setting 0 means Auto path c…
1.3.6.1.4.1.4756.20.502.20.1.1209ColumnnidMSTI9Port3PriorityRemoteBread-writecurrentNID Series card MSTI Port Configuration: MSTI9 Normal Port3 Configuration - Priority
1.3.6.1.4.1.4756.20.502.20.1.1210ColumnnidMSTI9Port4PathCostRemoteBread-writecurrentNID Series card MSTI Port Configuration: MSTI9 Normal Port4 Configuration - Path Cost Valid values are in the range 0 to 200000000. Setting 0 means Auto path c…
1.3.6.1.4.1.4756.20.502.20.1.1211ColumnnidMSTI9Port4PriorityRemoteBread-writecurrentNID Series card MSTI Port Configuration: MSTI9 Normal Port4 Configuration - Priority
1.3.6.1.4.1.4756.20.502.20.1.1212ColumnnidMSTI9Port5PathCostRemoteBread-writecurrentNID Series card MSTI Port Configuration: MSTI9 Normal Port5 Configuration - Path Cost Valid values are in the range 0 to 200000000. Setting 0 means Auto path c…
1.3.6.1.4.1.4756.20.502.20.1.1213ColumnnidMSTI9Port5PriorityRemoteBread-writecurrentNID Series card MSTI Port Configuration: MSTI9 Normal Port5 Configuration - Priority
1.3.6.1.4.1.4756.20.502.20.1.1214ColumnnidMSTI9Port6PathCostRemoteBread-writecurrentNID Series card MSTI Port Configuration: MSTI9 Normal Port6 Configuration - Path Cost Valid values are in the range 0 to 200000000. Setting 0 means Auto path c…
1.3.6.1.4.1.4756.20.502.20.1.1215ColumnnidMSTI9Port6PriorityRemoteBread-writecurrentNID Series card MSTI Port Configuration: MSTI9 Normal Port6 Configuration - Priority
1.3.6.1.4.1.4756.20.502.20.1.1216ColumnnidMSTI9Port7PathCostRemoteBread-writecurrentNID Series card MSTI Port Configuration: MSTI9 Normal Port7 Configuration - Path Cost Valid values are in the range 0 to 200000000. Setting 0 means Auto path c…
1.3.6.1.4.1.4756.20.502.20.1.1217ColumnnidMSTI9Port7PriorityRemoteBread-writecurrentNID Series card MSTI Port Configuration: MSTI9 Normal Port7 Configuration - Priority
1.3.6.1.4.1.4756.20.502.20.1.1218ColumnnidMSTI9Port8PathCostRemoteBread-writecurrentNID Series card MSTI Port Configuration: MSTI8 Normal Port8 Configuration - Path Cost Valid values are in the range 0 to 200000000. Setting 0 means Auto path c…
1.3.6.1.4.1.4756.20.502.20.1.1219ColumnnidMSTI9Port8PriorityRemoteBread-writecurrentNID Series card MSTI Port Configuration: MSTI9 Normal Port8 Configuration - Priority
1.3.6.1.4.1.4756.20.502.20.1.1220ColumnnidMSTI10AggregatedPathCostRemoteBread-writecurrentNID Series card MSTI Port Configuration: MSTI10 Aggregated Ports Configuration - Path Cost Valid values are in the range 0 to 200000000. Setting 0 means Auto p…
1.3.6.1.4.1.4756.20.502.20.1.1221ColumnnidMSTI10AggregatedPriorityRemoteBread-writecurrentNID Series card MSTI Port Configuration: MSTI10 Aggregated Ports Configuration - Priority
1.3.6.1.4.1.4756.20.502.20.1.1222ColumnnidMSTI10Port1PathCostRemoteBread-writecurrentNID Series card MSTI Port Configuration: MSTI10 Normal Port1 Configuration - Path Cost Valid values are in the range 0 to 200000000. Setting 0 means Auto path …
1.3.6.1.4.1.4756.20.502.20.1.1223ColumnnidMSTI10Port1PriorityRemoteBread-writecurrentNID Series card MSTI Port Configuration: MSTI10 Normal Port1 Configuration - Priority
1.3.6.1.4.1.4756.20.502.20.1.1224ColumnnidMSTI10Port2PathCostRemoteBread-writecurrentNID Series card MSTI Port Configuration: MSTI10 Normal Port2 Configuration - Path Cost Valid values are in the range 0 to 200000000. Setting 0 means Auto path …
1.3.6.1.4.1.4756.20.502.20.1.1225ColumnnidMSTI10Port2PriorityRemoteBread-writecurrentNID Series card MSTI Port Configuration: MSTI8 Normal Port2 Configuration - Priority
1.3.6.1.4.1.4756.20.502.20.1.1226ColumnnidMSTI10Port3PathCostRemoteBread-writecurrentNID Series card MSTI Port Configuration: MSTI8 Normal Port3 Configuration - Path Cost Valid values are in the range 0 to 200000000. Setting 0 means Auto path c…
1.3.6.1.4.1.4756.20.502.20.1.1227ColumnnidMSTI10Port3PriorityRemoteBread-writecurrentNID Series card MSTI Port Configuration: MSTI10 Normal Port3 Configuration - Priority
1.3.6.1.4.1.4756.20.502.20.1.1228ColumnnidMSTI10Port4PathCostRemoteBread-writecurrentNID Series card MSTI Port Configuration: MSTI10 Normal Port4 Configuration - Path Cost Valid values are in the range 0 to 200000000. Setting 0 means Auto path …
1.3.6.1.4.1.4756.20.502.20.1.1229ColumnnidMSTI10Port4PriorityRemoteBread-writecurrentNID Series card MSTI Port Configuration: MSTI10 Normal Port4 Configuration - Priority
1.3.6.1.4.1.4756.20.502.20.1.1230ColumnnidMSTI10Port5PathCostRemoteBread-writecurrentNID Series card MSTI Port Configuration: MSTI10 Normal Port5 Configuration - Path Cost Valid values are in the range 0 to 200000000. Setting 0 means Auto path …
1.3.6.1.4.1.4756.20.502.20.1.1231ColumnnidMSTI10Port5PriorityRemoteBread-writecurrentNID Series card MSTI Port Configuration: MSTI10 Normal Port5 Configuration - Priority
1.3.6.1.4.1.4756.20.502.20.1.1232ColumnnidMSTI10Port6PathCostRemoteBread-writecurrentNID Series card MSTI Port Configuration: MSTI10 Normal Port6 Configuration - Path Cost Valid values are in the range 0 to 200000000. Setting 0 means Auto path …
1.3.6.1.4.1.4756.20.502.20.1.1233ColumnnidMSTI10Port6PriorityRemoteBread-writecurrentNID Series card MSTI Port Configuration: MSTI10 Normal Port6 Configuration - Priority
1.3.6.1.4.1.4756.20.502.20.1.1234ColumnnidMSTI10Port7PathCostRemoteBread-writecurrentNID Series card MSTI Port Configuration: MSTI10 Normal Port7 Configuration - Path Cost Valid values are in the range 0 to 200000000. Setting 0 means Auto path …
1.3.6.1.4.1.4756.20.502.20.1.1235ColumnnidMSTI10Port7PriorityRemoteBread-writecurrentNID Series card MSTI Port Configuration: MSTI10 Normal Port7 Configuration - Priority
1.3.6.1.4.1.4756.20.502.20.1.1236ColumnnidMSTI10Port8PathCostRemoteBread-writecurrentNID Series card MSTI Port Configuration: MSTI8 Normal Port8 Configuration - Path Cost Valid values are in the range 0 to 200000000. Setting 0 means Auto path c…
1.3.6.1.4.1.4756.20.502.20.1.1237ColumnnidMSTI10Port8PriorityRemoteBread-writecurrentNID Series card MSTI Port Configuration: MSTI10 Normal Port8 Configuration - Priority
1.3.6.1.4.1.4756.20.502.20.1.1238ColumnnidMSTI11AggregatedPathCostRemoteBread-writecurrentNID Series card MSTI Port Configuration: MSTI11 Aggregated Ports Configuration - Path Cost Valid values are in the range 0 to 200000000. Setting 0 means Auto p…
1.3.6.1.4.1.4756.20.502.20.1.1239ColumnnidMSTI11AggregatedPriorityRemoteBread-writecurrentNID Series card MSTI Port Configuration: MSTI11 Aggregated Ports Configuration - Priority
1.3.6.1.4.1.4756.20.502.20.1.1240ColumnnidMSTI11Port1PathCostRemoteBread-writecurrentNID Series card MSTI Port Configuration: MSTI11 Normal Port1 Configuration - Path Cost Valid values are in the range 0 to 200000000. Setting 0 means Auto path …
1.3.6.1.4.1.4756.20.502.20.1.1241ColumnnidMSTI11Port1PriorityRemoteBread-writecurrentNID Series card MSTI Port Configuration: MSTI11 Normal Port1 Configuration - Priority
1.3.6.1.4.1.4756.20.502.20.1.1242ColumnnidMSTI11Port2PathCostRemoteBread-writecurrentNID Series card MSTI Port Configuration: MSTI11 Normal Port2 Configuration - Path Cost Valid values are in the range 0 to 200000000. Setting 0 means Auto path …
1.3.6.1.4.1.4756.20.502.20.1.1243ColumnnidMSTI11Port2PriorityRemoteBread-writecurrentNID Series card MSTI Port Configuration: MSTI8 Normal Port2 Configuration - Priority
1.3.6.1.4.1.4756.20.502.20.1.1244ColumnnidMSTI11Port3PathCostRemoteBread-writecurrentNID Series card MSTI Port Configuration: MSTI8 Normal Port3 Configuration - Path Cost Valid values are in the range 0 to 200000000. Setting 0 means Auto path c…
1.3.6.1.4.1.4756.20.502.20.1.1245ColumnnidMSTI11Port3PriorityRemoteBread-writecurrentNID Series card MSTI Port Configuration: MSTI11 Normal Port3 Configuration - Priority
1.3.6.1.4.1.4756.20.502.20.1.1246ColumnnidMSTI11Port4PathCostRemoteBread-writecurrentNID Series card MSTI Port Configuration: MSTI11 Normal Port4 Configuration - Path Cost Valid values are in the range 0 to 200000000. Setting 0 means Auto path …
1.3.6.1.4.1.4756.20.502.20.1.1247ColumnnidMSTI11Port4PriorityRemoteBread-writecurrentNID Series card MSTI Port Configuration: MSTI11 Normal Port4 Configuration - Priority
1.3.6.1.4.1.4756.20.502.20.1.1248ColumnnidMSTI11Port5PathCostRemoteBread-writecurrentNID Series card MSTI Port Configuration: MSTI11 Normal Port5 Configuration - Path Cost Valid values are in the range 0 to 200000000. Setting 0 means Auto path …
1.3.6.1.4.1.4756.20.502.20.1.1249ColumnnidMSTI11Port5PriorityRemoteBread-writecurrentNID Series card MSTI Port Configuration: MSTI11 Normal Port5 Configuration - Priority
1.3.6.1.4.1.4756.20.502.20.1.1250ColumnnidMSTI11Port6PathCostRemoteBread-writecurrentNID Series card MSTI Port Configuration: MSTI11 Normal Port6 Configuration - Path Cost Valid values are in the range 0 to 200000000. Setting 0 means Auto path …
1.3.6.1.4.1.4756.20.502.20.1.1251ColumnnidMSTI11Port6PriorityRemoteBread-writecurrentNID Series card MSTI Port Configuration: MSTI11 Normal Port6 Configuration - Priority
1.3.6.1.4.1.4756.20.502.20.1.1252ColumnnidMSTI11Port7PathCostRemoteBread-writecurrentNID Series card MSTI Port Configuration: MSTI11 Normal Port7 Configuration - Path Cost Valid values are in the range 0 to 200000000. Setting 0 means Auto path …
1.3.6.1.4.1.4756.20.502.20.1.1253ColumnnidMSTI11Port7PriorityRemoteBread-writecurrentNID Series card MSTI Port Configuration: MSTI11 Normal Port7 Configuration - Priority
1.3.6.1.4.1.4756.20.502.20.1.1254ColumnnidMSTI11Port8PathCostRemoteBread-writecurrentNID Series card MSTI Port Configuration: MSTI8 Normal Port8 Configuration - Path Cost Valid values are in the range 0 to 200000000. Setting 0 means Auto path c…
1.3.6.1.4.1.4756.20.502.20.1.1255ColumnnidMSTI11Port8PriorityRemoteBread-writecurrentNID Series card MSTI Port Configuration: MSTI11 Normal Port8 Configuration - Priority
1.3.6.1.4.1.4756.20.502.20.1.1256ColumnnidMSTI12AggregatedPathCostRemoteBread-writecurrentNID Series card MSTI Port Configuration: MSTI12 Aggregated Ports Configuration - Path Cost Valid values are in the range 0 to 200000000. Setting 0 means Auto p…
1.3.6.1.4.1.4756.20.502.20.1.1257ColumnnidMSTI12AggregatedPriorityRemoteBread-writecurrentNID Series card MSTI Port Configuration: MSTI12 Aggregated Ports Configuration - Priority
1.3.6.1.4.1.4756.20.502.20.1.1258ColumnnidMSTI12Port1PathCostRemoteBread-writecurrentNID Series card MSTI Port Configuration: MSTI12 Normal Port1 Configuration - Path Cost Valid values are in the range 0 to 200000000. Setting 0 means Auto path …
1.3.6.1.4.1.4756.20.502.20.1.1259ColumnnidMSTI12Port1PriorityRemoteBread-writecurrentNID Series card MSTI Port Configuration: MSTI12 Normal Port1 Configuration - Priority
1.3.6.1.4.1.4756.20.502.20.1.1260ColumnnidMSTI12Port2PathCostRemoteBread-writecurrentNID Series card MSTI Port Configuration: MSTI12 Normal Port2 Configuration - Path Cost Valid values are in the range 0 to 200000000. Setting 0 means Auto path …
1.3.6.1.4.1.4756.20.502.20.1.1261ColumnnidMSTI12Port2PriorityRemoteBread-writecurrentNID Series card MSTI Port Configuration: MSTI8 Normal Port2 Configuration - Priority
1.3.6.1.4.1.4756.20.502.20.1.1262ColumnnidMSTI12Port3PathCostRemoteBread-writecurrentNID Series card MSTI Port Configuration: MSTI8 Normal Port3 Configuration - Path Cost Valid values are in the range 0 to 200000000. Setting 0 means Auto path c…
1.3.6.1.4.1.4756.20.502.20.1.1263ColumnnidMSTI12Port3PriorityRemoteBread-writecurrentNID Series card MSTI Port Configuration: MSTI12 Normal Port3 Configuration - Priority
1.3.6.1.4.1.4756.20.502.20.1.1264ColumnnidMSTI12Port4PathCostRemoteBread-writecurrentNID Series card MSTI Port Configuration: MSTI12 Normal Port4 Configuration - Path Cost Valid values are in the range 0 to 200000000. Setting 0 means Auto path …
1.3.6.1.4.1.4756.20.502.20.1.1265ColumnnidMSTI12Port4PriorityRemoteBread-writecurrentNID Series card MSTI Port Configuration: MSTI12 Normal Port4 Configuration - Priority
1.3.6.1.4.1.4756.20.502.20.1.1266ColumnnidMSTI12Port5PathCostRemoteBread-writecurrentNID Series card MSTI Port Configuration: MSTI12 Normal Port5 Configuration - Path Cost Valid values are in the range 0 to 200000000. Setting 0 means Auto path …
1.3.6.1.4.1.4756.20.502.20.1.1267ColumnnidMSTI12Port5PriorityRemoteBread-writecurrentNID Series card MSTI Port Configuration: MSTI12 Normal Port5 Configuration - Priority
1.3.6.1.4.1.4756.20.502.20.1.1268ColumnnidMSTI12Port6PathCostRemoteBread-writecurrentNID Series card MSTI Port Configuration: MSTI12 Normal Port6 Configuration - Path Cost Valid values are in the range 0 to 200000000. Setting 0 means Auto path …
1.3.6.1.4.1.4756.20.502.20.1.1269ColumnnidMSTI12Port6PriorityRemoteBread-writecurrentNID Series card MSTI Port Configuration: MSTI12 Normal Port6 Configuration - Priority
1.3.6.1.4.1.4756.20.502.20.1.1270ColumnnidMSTI12Port7PathCostRemoteBread-writecurrentNID Series card MSTI Port Configuration: MSTI12 Normal Port7 Configuration - Path Cost Valid values are in the range 0 to 200000000. Setting 0 means Auto path …
1.3.6.1.4.1.4756.20.502.20.1.1271ColumnnidMSTI12Port7PriorityRemoteBread-writecurrentNID Series card MSTI Port Configuration: MSTI12 Normal Port7 Configuration - Priority
1.3.6.1.4.1.4756.20.502.20.1.1272ColumnnidMSTI12Port8PathCostRemoteBread-writecurrentNID Series card MSTI Port Configuration: MSTI8 Normal Port8 Configuration - Path Cost Valid values are in the range 0 to 200000000. Setting 0 means Auto path c…
1.3.6.1.4.1.4756.20.502.20.1.1273ColumnnidMSTI12Port8PriorityRemoteBread-writecurrentNID Series card MSTI Port Configuration: MSTI12 Normal Port8 Configuration - Priority
1.3.6.1.4.1.4756.20.502.20.1.1274ColumnnidMSTI13AggregatedPathCostRemoteBread-writecurrentNID Series card MSTI Port Configuration: MSTI13 Aggregated Ports Configuration - Path Cost Valid values are in the range 0 to 200000000. Setting 0 means Auto p…
1.3.6.1.4.1.4756.20.502.20.1.1275ColumnnidMSTI13AggregatedPriorityRemoteBread-writecurrentNID Series card MSTI Port Configuration: MSTI13 Aggregated Ports Configuration - Priority
1.3.6.1.4.1.4756.20.502.20.1.1276ColumnnidMSTI13Port1PathCostRemoteBread-writecurrentNID Series card MSTI Port Configuration: MSTI13 Normal Port1 Configuration - Path Cost Valid values are in the range 0 to 200000000. Setting 0 means Auto path …
1.3.6.1.4.1.4756.20.502.20.1.1277ColumnnidMSTI13Port1PriorityRemoteBread-writecurrentNID Series card MSTI Port Configuration: MSTI13 Normal Port1 Configuration - Priority
1.3.6.1.4.1.4756.20.502.20.1.1278ColumnnidMSTI13Port2PathCostRemoteBread-writecurrentNID Series card MSTI Port Configuration: MSTI13 Normal Port2 Configuration - Path Cost Valid values are in the range 0 to 200000000. Setting 0 means Auto path …
1.3.6.1.4.1.4756.20.502.20.1.1279ColumnnidMSTI13Port2PriorityRemoteBread-writecurrentNID Series card MSTI Port Configuration: MSTI8 Normal Port2 Configuration - Priority
1.3.6.1.4.1.4756.20.502.20.1.1280ColumnnidMSTI13Port3PathCostRemoteBread-writecurrentNID Series card MSTI Port Configuration: MSTI8 Normal Port3 Configuration - Path Cost Valid values are in the range 0 to 200000000. Setting 0 means Auto path c…
1.3.6.1.4.1.4756.20.502.20.1.1281ColumnnidMSTI13Port3PriorityRemoteBread-writecurrentNID Series card MSTI Port Configuration: MSTI13 Normal Port3 Configuration - Priority
1.3.6.1.4.1.4756.20.502.20.1.1282ColumnnidMSTI13Port4PathCostRemoteBread-writecurrentNID Series card MSTI Port Configuration: MSTI13 Normal Port4 Configuration - Path Cost Valid values are in the range 0 to 200000000. Setting 0 means Auto path …
1.3.6.1.4.1.4756.20.502.20.1.1283ColumnnidMSTI13Port4PriorityRemoteBread-writecurrentNID Series card MSTI Port Configuration: MSTI13 Normal Port4 Configuration - Priority
1.3.6.1.4.1.4756.20.502.20.1.1284ColumnnidMSTI13Port5PathCostRemoteBread-writecurrentNID Series card MSTI Port Configuration: MSTI13 Normal Port5 Configuration - Path Cost Valid values are in the range 0 to 200000000. Setting 0 means Auto path …
1.3.6.1.4.1.4756.20.502.20.1.1285ColumnnidMSTI13Port5PriorityRemoteBread-writecurrentNID Series card MSTI Port Configuration: MSTI13 Normal Port5 Configuration - Priority
1.3.6.1.4.1.4756.20.502.20.1.1286ColumnnidMSTI13Port6PathCostRemoteBread-writecurrentNID Series card MSTI Port Configuration: MSTI13 Normal Port6 Configuration - Path Cost Valid values are in the range 0 to 200000000. Setting 0 means Auto path …
1.3.6.1.4.1.4756.20.502.20.1.1287ColumnnidMSTI13Port6PriorityRemoteBread-writecurrentNID Series card MSTI Port Configuration: MSTI13 Normal Port6 Configuration - Priority
1.3.6.1.4.1.4756.20.502.20.1.1288ColumnnidMSTI13Port7PathCostRemoteBread-writecurrentNID Series card MSTI Port Configuration: MSTI13 Normal Port7 Configuration - Path Cost Valid values are in the range 0 to 200000000. Setting 0 means Auto path …
1.3.6.1.4.1.4756.20.502.20.1.1289ColumnnidMSTI13Port7PriorityRemoteBread-writecurrentNID Series card MSTI Port Configuration: MSTI13 Normal Port7 Configuration - Priority
1.3.6.1.4.1.4756.20.502.20.1.1290ColumnnidMSTI13Port8PathCostRemoteBread-writecurrentNID Series card MSTI Port Configuration: MSTI8 Normal Port8 Configuration - Path Cost Valid values are in the range 0 to 200000000. Setting 0 means Auto path c…
1.3.6.1.4.1.4756.20.502.20.1.1291ColumnnidMSTI13Port8PriorityRemoteBread-writecurrentNID Series card MSTI Port Configuration: MSTI13 Normal Port8 Configuration - Priority
1.3.6.1.4.1.4756.20.502.20.1.1292ColumnnidMSTI14AggregatedPathCostRemoteBread-writecurrentNID Series card MSTI Port Configuration: MSTI14 Aggregated Ports Configuration - Path Cost Valid values are in the range 0 to 200000000. Setting 0 means Auto p…
1.3.6.1.4.1.4756.20.502.20.1.1293ColumnnidMSTI14AggregatedPriorityRemoteBread-writecurrentNID Series card MSTI Port Configuration: MSTI14 Aggregated Ports Configuration - Priority
1.3.6.1.4.1.4756.20.502.20.1.1294ColumnnidMSTI14Port1PathCostRemoteBread-writecurrentNID Series card MSTI Port Configuration: MSTI14 Normal Port1 Configuration - Path Cost Valid values are in the range 0 to 200000000. Setting 0 means Auto path …
1.3.6.1.4.1.4756.20.502.20.1.1295ColumnnidMSTI14Port1PriorityRemoteBread-writecurrentNID Series card MSTI Port Configuration: MSTI14 Normal Port1 Configuration - Priority
1.3.6.1.4.1.4756.20.502.20.1.1296ColumnnidMSTI14Port2PathCostRemoteBread-writecurrentNID Series card MSTI Port Configuration: MSTI14 Normal Port2 Configuration - Path Cost Valid values are in the range 0 to 200000000. Setting 0 means Auto path …
1.3.6.1.4.1.4756.20.502.20.1.1297ColumnnidMSTI14Port2PriorityRemoteBread-writecurrentNID Series card MSTI Port Configuration: MSTI8 Normal Port2 Configuration - Priority
1.3.6.1.4.1.4756.20.502.20.1.1298ColumnnidMSTI14Port3PathCostRemoteBread-writecurrentNID Series card MSTI Port Configuration: MSTI8 Normal Port3 Configuration - Path Cost Valid values are in the range 0 to 200000000. Setting 0 means Auto path c…
1.3.6.1.4.1.4756.20.502.20.1.1299ColumnnidMSTI14Port3PriorityRemoteBread-writecurrentNID Series card MSTI Port Configuration: MSTI14 Normal Port3 Configuration - Priority
1.3.6.1.4.1.4756.20.502.20.1.1300ColumnnidMSTI14Port4PathCostRemoteBread-writecurrentNID Series card MSTI Port Configuration: MSTI14 Normal Port4 Configuration - Path Cost Valid values are in the range 0 to 200000000. Setting 0 means Auto path …
1.3.6.1.4.1.4756.20.502.20.1.1301ColumnnidMSTI14Port4PriorityRemoteBread-writecurrentNID Series card MSTI Port Configuration: MSTI14 Normal Port4 Configuration - Priority
1.3.6.1.4.1.4756.20.502.20.1.1302ColumnnidMSTI14Port5PathCostRemoteBread-writecurrentNID Series card MSTI Port Configuration: MSTI14 Normal Port5 Configuration - Path Cost Valid values are in the range 0 to 200000000. Setting 0 means Auto path …
1.3.6.1.4.1.4756.20.502.20.1.1303ColumnnidMSTI14Port5PriorityRemoteBread-writecurrentNID Series card MSTI Port Configuration: MSTI14 Normal Port5 Configuration - Priority
1.3.6.1.4.1.4756.20.502.20.1.1304ColumnnidMSTI14Port6PathCostRemoteBread-writecurrentNID Series card MSTI Port Configuration: MSTI14 Normal Port6 Configuration - Path Cost Valid values are in the range 0 to 200000000. Setting 0 means Auto path …
1.3.6.1.4.1.4756.20.502.20.1.1305ColumnnidMSTI14Port6PriorityRemoteBread-writecurrentNID Series card MSTI Port Configuration: MSTI14 Normal Port6 Configuration - Priority
1.3.6.1.4.1.4756.20.502.20.1.1306ColumnnidMSTI14Port7PathCostRemoteBread-writecurrentNID Series card MSTI Port Configuration: MSTI14 Normal Port7 Configuration - Path Cost Valid values are in the range 0 to 200000000. Setting 0 means Auto path …
1.3.6.1.4.1.4756.20.502.20.1.1307ColumnnidMSTI14Port7PriorityRemoteBread-writecurrentNID Series card MSTI Port Configuration: MSTI14 Normal Port7 Configuration - Priority
1.3.6.1.4.1.4756.20.502.20.1.1308ColumnnidMSTI14Port8PathCostRemoteBread-writecurrentNID Series card MSTI Port Configuration: MSTI8 Normal Port8 Configuration - Path Cost Valid values are in the range 0 to 200000000. Setting 0 means Auto path c…
1.3.6.1.4.1.4756.20.502.20.1.1309ColumnnidMSTI14Port8PriorityRemoteBread-writecurrentNID Series card MSTI Port Configuration: MSTI14 Normal Port8 Configuration - Priority
1.3.6.1.4.1.4756.20.502.20.1.1310ColumnnidMSTI15AggregatedPathCostRemoteBread-writecurrentNID Series card MSTI Port Configuration: MSTI15 Aggregated Ports Configuration - Path Cost Valid values are in the range 0 to 200000000. Setting 0 means Auto p…
1.3.6.1.4.1.4756.20.502.20.1.1311ColumnnidMSTI15AggregatedPriorityRemoteBread-writecurrentNID Series card MSTI Port Configuration: MSTI15 Aggregated Ports Configuration - Priority
1.3.6.1.4.1.4756.20.502.20.1.1312ColumnnidMSTI15Port1PathCostRemoteBread-writecurrentNID Series card MSTI Port Configuration: MSTI15 Normal Port1 Configuration - Path Cost Valid values are in the range 0 to 200000000. Setting 0 means Auto path …
1.3.6.1.4.1.4756.20.502.20.1.1313ColumnnidMSTI15Port1PriorityRemoteBread-writecurrentNID Series card MSTI Port Configuration: MSTI15 Normal Port1 Configuration - Priority
1.3.6.1.4.1.4756.20.502.20.1.1314ColumnnidMSTI15Port2PathCostRemoteBread-writecurrentNID Series card MSTI Port Configuration: MSTI15 Normal Port2 Configuration - Path Cost Valid values are in the range 0 to 200000000. Setting 0 means Auto path …
1.3.6.1.4.1.4756.20.502.20.1.1315ColumnnidMSTI15Port2PriorityRemoteBread-writecurrentNID Series card MSTI Port Configuration: MSTI8 Normal Port2 Configuration - Priority
1.3.6.1.4.1.4756.20.502.20.1.1316ColumnnidMSTI15Port3PathCostRemoteBread-writecurrentNID Series card MSTI Port Configuration: MSTI8 Normal Port3 Configuration - Path Cost Valid values are in the range 0 to 200000000. Setting 0 means Auto path c…
1.3.6.1.4.1.4756.20.502.20.1.1317ColumnnidMSTI15Port3PriorityRemoteBread-writecurrentNID Series card MSTI Port Configuration: MSTI15 Normal Port3 Configuration - Priority
1.3.6.1.4.1.4756.20.502.20.1.1318ColumnnidMSTI15Port4PathCostRemoteBread-writecurrentNID Series card MSTI Port Configuration: MSTI15 Normal Port4 Configuration - Path Cost Valid values are in the range 0 to 200000000. Setting 0 means Auto path …
1.3.6.1.4.1.4756.20.502.20.1.1319ColumnnidMSTI15Port4PriorityRemoteBread-writecurrentNID Series card MSTI Port Configuration: MSTI15 Normal Port4 Configuration - Priority
1.3.6.1.4.1.4756.20.502.20.1.1320ColumnnidMSTI15Port5PathCostRemoteBread-writecurrentNID Series card MSTI Port Configuration: MSTI15 Normal Port5 Configuration - Path Cost Valid values are in the range 0 to 200000000. Setting 0 means Auto path …
1.3.6.1.4.1.4756.20.502.20.1.1321ColumnnidMSTI15Port5PriorityRemoteBread-writecurrentNID Series card MSTI Port Configuration: MSTI15 Normal Port5 Configuration - Priority
1.3.6.1.4.1.4756.20.502.20.1.1322ColumnnidMSTI15Port6PathCostRemoteBread-writecurrentNID Series card MSTI Port Configuration: MSTI15 Normal Port6 Configuration - Path Cost Valid values are in the range 0 to 200000000. Setting 0 means Auto path …
1.3.6.1.4.1.4756.20.502.20.1.1323ColumnnidMSTI15Port6PriorityRemoteBread-writecurrentNID Series card MSTI Port Configuration: MSTI15 Normal Port6 Configuration - Priority
1.3.6.1.4.1.4756.20.502.20.1.1324ColumnnidMSTI15Port7PathCostRemoteBread-writecurrentNID Series card MSTI Port Configuration: MSTI15 Normal Port7 Configuration - Path Cost Valid values are in the range 0 to 200000000. Setting 0 means Auto path …
1.3.6.1.4.1.4756.20.502.20.1.1325ColumnnidMSTI15Port7PriorityRemoteBread-writecurrentNID Series card MSTI Port Configuration: MSTI15 Normal Port7 Configuration - Priority
1.3.6.1.4.1.4756.20.502.20.1.1326ColumnnidMSTI15Port8PathCostRemoteBread-writecurrentNID Series card MSTI Port Configuration: MSTI8 Normal Port8 Configuration - Path Cost Valid values are in the range 0 to 200000000. Setting 0 means Auto path c…
1.3.6.1.4.1.4756.20.502.20.1.1327ColumnnidMSTI15Port8PriorityRemoteBread-writecurrentNID Series card MSTI Port Configuration: MSTI15 Normal Port8 Configuration - Priority
1.3.6.1.4.1.4756.20.502.20.1.1328ColumnnidCISTBridgeIDRemoteBread-onlycurrentNID Series card STP Bridges status: CIST - Bridge ID
1.3.6.1.4.1.4756.20.502.20.1.1329ColumnnidCISTRootIDRemoteBread-onlycurrentNID Series card STP Bridges status: CIST - Root ID
1.3.6.1.4.1.4756.20.502.20.1.1330ColumnnidCISTRootPortRemoteBread-onlycurrentNID Series card STP Bridges status: CIST - Root Port
1.3.6.1.4.1.4756.20.502.20.1.1331ColumnnidCISTRootCostRemoteBread-onlycurrentNID Series card STP Bridges status: CIST - Root Cost
1.3.6.1.4.1.4756.20.502.20.1.1332ColumnnidCISTTopologyFlagRemoteBread-onlycurrentNID Series card STP Bridges status: CIST - Topology Flag
1.3.6.1.4.1.4756.20.502.20.1.1333ColumnnidCISTTopologyChangeLastRemoteBread-onlycurrentNID Series card STP Bridges status: CIST - Topology Change Last
1.3.6.1.4.1.4756.20.502.20.1.1334ColumnnidMSTI1BridgeIDRemoteBread-onlycurrentNID Series card STP Bridges status: MSTI1 - Bridge ID
1.3.6.1.4.1.4756.20.502.20.1.1335ColumnnidMSTI1RootIDRemoteBread-onlycurrentNID Series card STP Bridges status: MSTI1 - Root ID
1.3.6.1.4.1.4756.20.502.20.1.1336ColumnnidMSTI1RootPortRemoteBread-onlycurrentNID Series card STP Bridges status: MSTI1 - Root ID
1.3.6.1.4.1.4756.20.502.20.1.1337ColumnnidMSTI1RootCostRemoteBread-onlycurrentNID Series card STP Bridges status: MSTI1 - Root Cost
1.3.6.1.4.1.4756.20.502.20.1.1338ColumnnidMSTI1TopologyFlagRemoteBread-onlycurrentNID Series card STP Bridges status: MSTI1 - Topology Flag
1.3.6.1.4.1.4756.20.502.20.1.1339ColumnnidMSTI1TopologyChangeLastRemoteBread-onlycurrentNID Series card STP Bridges status: MSTI1 - Topology Change Last
1.3.6.1.4.1.4756.20.502.20.1.1340ColumnnidMSTI2BridgeIDRemoteBread-onlycurrentNID Series card STP Bridges status: MSTI2 - Bridge ID
1.3.6.1.4.1.4756.20.502.20.1.1341ColumnnidMSTI2RootIDRemoteBread-onlycurrentNID Series card STP Bridges status: MSTI2 - Root ID
1.3.6.1.4.1.4756.20.502.20.1.1342ColumnnidMSTI2RootPortRemoteBread-onlycurrentNID Series card STP Bridges status: MSTI2 - Root ID
1.3.6.1.4.1.4756.20.502.20.1.1343ColumnnidMSTI2RootCostRemoteBread-onlycurrentNID Series card STP Bridges status: MSTI2 - Root Cost
1.3.6.1.4.1.4756.20.502.20.1.1344ColumnnidMSTI2TopologyFlagRemoteBread-onlycurrentNID Series card STP Bridges status: MSTI2 - Topology Flag
1.3.6.1.4.1.4756.20.502.20.1.1345ColumnnidMSTI2TopologyChangeLastRemoteBread-onlycurrentNID Series card STP Bridges status: MSTI2 - Topology Change Last
1.3.6.1.4.1.4756.20.502.20.1.1346ColumnnidMSTI3BridgeIDRemoteBread-onlycurrentNID Series card STP Bridges status: MSTI3 - Bridge ID
1.3.6.1.4.1.4756.20.502.20.1.1347ColumnnidMSTI3RootIDRemoteBread-onlycurrentNID Series card STP Bridges status: MSTI3 - Root ID
1.3.6.1.4.1.4756.20.502.20.1.1348ColumnnidMSTI3RootPortRemoteBread-onlycurrentNID Series card STP Bridges status: MSTI3 - Root ID
1.3.6.1.4.1.4756.20.502.20.1.1349ColumnnidMSTI3RootCostRemoteBread-onlycurrentNID Series card STP Bridges status: MSTI3 - Root Cost
1.3.6.1.4.1.4756.20.502.20.1.1350ColumnnidMSTI3TopologyFlagRemoteBread-onlycurrentNID Series card STP Bridges status: MSTI3 - Topology Flag
1.3.6.1.4.1.4756.20.502.20.1.1351ColumnnidMSTI3TopologyChangeLastRemoteBread-onlycurrentNID Series card STP Bridges status: MSTI3 - Topology Change Last
1.3.6.1.4.1.4756.20.502.20.1.1352ColumnnidMSTI4BridgeIDRemoteBread-onlycurrentNID Series card STP Bridges status: MSTI4 - Bridge ID
1.3.6.1.4.1.4756.20.502.20.1.1353ColumnnidMSTI4RootIDRemoteBread-onlycurrentNID Series card STP Bridges status: MSTI4 - Root ID
1.3.6.1.4.1.4756.20.502.20.1.1354ColumnnidMSTI4RootPortRemoteBread-onlycurrentNID Series card STP Bridges status: MSTI4 - Root ID
1.3.6.1.4.1.4756.20.502.20.1.1355ColumnnidMSTI4RootCostRemoteBread-onlycurrentNID Series card STP Bridges status: MSTI4 - Root Cost
1.3.6.1.4.1.4756.20.502.20.1.1356ColumnnidMSTI4TopologyFlagRemoteBread-onlycurrentNID Series card STP Bridges status: MSTI4 - Topology Flag
1.3.6.1.4.1.4756.20.502.20.1.1357ColumnnidMSTI4TopologyChangeLastRemoteBread-onlycurrentNID Series card STP Bridges status: MSTI4 - Topology Change Last
1.3.6.1.4.1.4756.20.502.20.1.1358ColumnnidMSTI5BridgeIDRemoteBread-onlycurrentNID Series card STP Bridges status: MSTI5 - Bridge ID
1.3.6.1.4.1.4756.20.502.20.1.1359ColumnnidMSTI5RootIDRemoteBread-onlycurrentNID Series card STP Bridges status: MSTI5 - Root ID
1.3.6.1.4.1.4756.20.502.20.1.1360ColumnnidMSTI5RootPortRemoteBread-onlycurrentNID Series card STP Bridges status: MSTI5 - Root ID
1.3.6.1.4.1.4756.20.502.20.1.1361ColumnnidMSTI5RootCostRemoteBread-onlycurrentNID Series card STP Bridges status: MSTI5 - Root Cost
1.3.6.1.4.1.4756.20.502.20.1.1362ColumnnidMSTI5TopologyFlagRemoteBread-onlycurrentNID Series card STP Bridges status: MSTI5 - Topology Flag
1.3.6.1.4.1.4756.20.502.20.1.1363ColumnnidMSTI5TopologyChangeLastRemoteBread-onlycurrentNID Series card STP Bridges status: MSTI5 - Topology Change Last
1.3.6.1.4.1.4756.20.502.20.1.1364ColumnnidMSTI6BridgeIDRemoteBread-onlycurrentNID Series card STP Bridges status: MSTI6 - Bridge ID
1.3.6.1.4.1.4756.20.502.20.1.1365ColumnnidMSTI6RootIDRemoteBread-onlycurrentNID Series card STP Bridges status: MSTI6 - Root ID
1.3.6.1.4.1.4756.20.502.20.1.1366ColumnnidMSTI6RootPortRemoteBread-onlycurrentNID Series card STP Bridges status: MSTI6 - Root ID
1.3.6.1.4.1.4756.20.502.20.1.1367ColumnnidMSTI6RootCostRemoteBread-onlycurrentNID Series card STP Bridges status: MSTI6 - Root Cost
1.3.6.1.4.1.4756.20.502.20.1.1368ColumnnidMSTI6TopologyFlagRemoteBread-onlycurrentNID Series card STP Bridges status: MSTI6 - Topology Flag
1.3.6.1.4.1.4756.20.502.20.1.1369ColumnnidMSTI6TopologyChangeLastRemoteBread-onlycurrentNID Series card STP Bridges status: MSTI6 - Topology Change Last
1.3.6.1.4.1.4756.20.502.20.1.1370ColumnnidMSTI7BridgeIDRemoteBread-onlycurrentNID Series card STP Bridges status: MSTI7 - Bridge ID
1.3.6.1.4.1.4756.20.502.20.1.1371ColumnnidMSTI7RootIDRemoteBread-onlycurrentNID Series card STP Bridges status: MSTI7 - Root ID
1.3.6.1.4.1.4756.20.502.20.1.1372ColumnnidMSTI7RootPortRemoteBread-onlycurrentNID Series card STP Bridges status: MSTI7 - Root ID
1.3.6.1.4.1.4756.20.502.20.1.1373ColumnnidMSTI7RootCostRemoteBread-onlycurrentNID Series card STP Bridges status: MSTI7 - Root Cost
1.3.6.1.4.1.4756.20.502.20.1.1374ColumnnidMSTI7TopologyFlagRemoteBread-onlycurrentNID Series card STP Bridges status: MSTI7 - Topology Flag
1.3.6.1.4.1.4756.20.502.20.1.1375ColumnnidMSTI7TopologyChangeLastRemoteBread-onlycurrentNID Series card STP Bridges status: MSTI7 - Topology Change Last
1.3.6.1.4.1.4756.20.502.20.1.1376ColumnnidMSTI8BridgeIDRemoteBread-onlycurrentNID Series card STP Bridges status: MSTI8 - Bridge ID
1.3.6.1.4.1.4756.20.502.20.1.1377ColumnnidMSTI8RootIDRemoteBread-onlycurrentNID Series card STP Bridges status: MSTI8 - Root ID
1.3.6.1.4.1.4756.20.502.20.1.1378ColumnnidMSTI8RootPortRemoteBread-onlycurrentNID Series card STP Bridges status: MSTI8 - Root ID
1.3.6.1.4.1.4756.20.502.20.1.1379ColumnnidMSTI8RootCostRemoteBread-onlycurrentNID Series card STP Bridges status: MSTI8 - Root Cost
1.3.6.1.4.1.4756.20.502.20.1.1380ColumnnidMSTI8TopologyFlagRemoteBread-onlycurrentNID Series card STP Bridges status: MSTI8 - Topology Flag
1.3.6.1.4.1.4756.20.502.20.1.1381ColumnnidMSTI8TopologyChangeLastRemoteBread-onlycurrentNID Series card STP Bridges status: MSTI8 - Topology Change Last
1.3.6.1.4.1.4756.20.502.20.1.1382ColumnnidMSTI9BridgeIDRemoteBread-onlycurrentNID Series card STP Bridges status: MSTI9 - Bridge ID
1.3.6.1.4.1.4756.20.502.20.1.1383ColumnnidMSTI9RootIDRemoteBread-onlycurrentNID Series card STP Bridges status: MSTI9 - Root ID
1.3.6.1.4.1.4756.20.502.20.1.1384ColumnnidMSTI9RootPortRemoteBread-onlycurrentNID Series card STP Bridges status: MSTI9 - Root ID
1.3.6.1.4.1.4756.20.502.20.1.1385ColumnnidMSTI9RootCostRemoteBread-onlycurrentNID Series card STP Bridges status: MSTI9 - Root Cost
1.3.6.1.4.1.4756.20.502.20.1.1386ColumnnidMSTI9TopologyFlagRemoteBread-onlycurrentNID Series card STP Bridges status: MSTI9 - Topology Flag
1.3.6.1.4.1.4756.20.502.20.1.1387ColumnnidMSTI9TopologyChangeLastRemoteBread-onlycurrentNID Series card STP Bridges status: MSTI9 - Topology Change Last
1.3.6.1.4.1.4756.20.502.20.1.1388ColumnnidMSTI10BridgeIDRemoteBread-onlycurrentNID Series card STP Bridges status: MSTI10 - Bridge ID
1.3.6.1.4.1.4756.20.502.20.1.1389ColumnnidMSTI10RootIDRemoteBread-onlycurrentNID Series card STP Bridges status: MSTI10 - Root ID
1.3.6.1.4.1.4756.20.502.20.1.1390ColumnnidMSTI10RootPortRemoteBread-onlycurrentNID Series card STP Bridges status: MSTI10 - Root ID
1.3.6.1.4.1.4756.20.502.20.1.1391ColumnnidMSTI10RootCostRemoteBread-onlycurrentNID Series card STP Bridges status: MSTI10 - Root Cost
1.3.6.1.4.1.4756.20.502.20.1.1392ColumnnidMSTI10TopologyFlagRemoteBread-onlycurrentNID Series card STP Bridges status: MSTI10 - Topology Flag
1.3.6.1.4.1.4756.20.502.20.1.1393ColumnnidMSTI10TopologyChangeLastRemoteBread-onlycurrentNID Series card STP Bridges status: MSTI10 - Topology Change Last
1.3.6.1.4.1.4756.20.502.20.1.1394ColumnnidMSTI11BridgeIDRemoteBread-onlycurrentNID Series card STP Bridges status: MSTI11 - Bridge ID
1.3.6.1.4.1.4756.20.502.20.1.1395ColumnnidMSTI11RootIDRemoteBread-onlycurrentNID Series card STP Bridges status: MSTI11 - Root ID
1.3.6.1.4.1.4756.20.502.20.1.1396ColumnnidMSTI11RootPortRemoteBread-onlycurrentNID Series card STP Bridges status: MSTI11 - Root ID
1.3.6.1.4.1.4756.20.502.20.1.1397ColumnnidMSTI11RootCostRemoteBread-onlycurrentNID Series card STP Bridges status: MSTI11 - Root Cost
1.3.6.1.4.1.4756.20.502.20.1.1398ColumnnidMSTI11TopologyFlagRemoteBread-onlycurrentNID Series card STP Bridges status: MSTI11 - Topology Flag
1.3.6.1.4.1.4756.20.502.20.1.1399ColumnnidMSTI11TopologyChangeLastRemoteBread-onlycurrentNID Series card STP Bridges status: MSTI11 - Topology Change Last
1.3.6.1.4.1.4756.20.502.20.1.1400ColumnnidMSTI12BridgeIDRemoteBread-onlycurrentNID Series card STP Bridges status: MSTI12 - Bridge ID
1.3.6.1.4.1.4756.20.502.20.1.1401ColumnnidMSTI12RootIDRemoteBread-onlycurrentNID Series card STP Bridges status: MSTI12 - Root ID
1.3.6.1.4.1.4756.20.502.20.1.1402ColumnnidMSTI12RootPortRemoteBread-onlycurrentNID Series card STP Bridges status: MSTI12 - Root ID
1.3.6.1.4.1.4756.20.502.20.1.1403ColumnnidMSTI12RootCostRemoteBread-onlycurrentNID Series card STP Bridges status: MSTI12 - Root Cost
1.3.6.1.4.1.4756.20.502.20.1.1404ColumnnidMSTI12TopologyFlagRemoteBread-onlycurrentNID Series card STP Bridges status: MSTI12 - Topology Flag
1.3.6.1.4.1.4756.20.502.20.1.1405ColumnnidMSTI12TopologyChangeLastRemoteBread-onlycurrentNID Series card STP Bridges status: MSTI12 - Topology Change Last
1.3.6.1.4.1.4756.20.502.20.1.1406ColumnnidMSTI13BridgeIDRemoteBread-onlycurrentNID Series card STP Bridges status: MSTI13 - Bridge ID
1.3.6.1.4.1.4756.20.502.20.1.1407ColumnnidMSTI13RootIDRemoteBread-onlycurrentNID Series card STP Bridges status: MSTI13 - Root ID
1.3.6.1.4.1.4756.20.502.20.1.1408ColumnnidMSTI13RootPortRemoteBread-onlycurrentNID Series card STP Bridges status: MSTI13 - Root ID
1.3.6.1.4.1.4756.20.502.20.1.1409ColumnnidMSTI13RootCostRemoteBread-onlycurrentNID Series card STP Bridges status: MSTI13 - Root Cost
1.3.6.1.4.1.4756.20.502.20.1.1410ColumnnidMSTI13TopologyFlagRemoteBread-onlycurrentNID Series card STP Bridges status: MSTI13 - Topology Flag
1.3.6.1.4.1.4756.20.502.20.1.1411ColumnnidMSTI13TopologyChangeLastRemoteBread-onlycurrentNID Series card STP Bridges status: MSTI13 - Topology Change Last
1.3.6.1.4.1.4756.20.502.20.1.1412ColumnnidMSTI14BridgeIDRemoteBread-onlycurrentNID Series card STP Bridges status: MSTI14 - Bridge ID
1.3.6.1.4.1.4756.20.502.20.1.1413ColumnnidMSTI14RootIDRemoteBread-onlycurrentNID Series card STP Bridges status: MSTI14 - Root ID
1.3.6.1.4.1.4756.20.502.20.1.1414ColumnnidMSTI14RootPortRemoteBread-onlycurrentNID Series card STP Bridges status: MSTI14 - Root ID
1.3.6.1.4.1.4756.20.502.20.1.1415ColumnnidMSTI14RootCostRemoteBread-onlycurrentNID Series card STP Bridges status: MSTI14 - Root Cost
1.3.6.1.4.1.4756.20.502.20.1.1416ColumnnidMSTI14TopologyFlagRemoteBread-onlycurrentNID Series card STP Bridges status: MSTI14 - Topology Flag
1.3.6.1.4.1.4756.20.502.20.1.1417ColumnnidMSTI14TopologyChangeLastRemoteBread-onlycurrentNID Series card STP Bridges status: MSTI14 - Topology Change Last
1.3.6.1.4.1.4756.20.502.20.1.1418ColumnnidMSTI15BridgeIDRemoteBread-onlycurrentNID Series card STP Bridges status: MSTI15 - Bridge ID
1.3.6.1.4.1.4756.20.502.20.1.1419ColumnnidMSTI15RootIDRemoteBread-onlycurrentNID Series card STP Bridges status: MSTI15 - Root ID
1.3.6.1.4.1.4756.20.502.20.1.1420ColumnnidMSTI15RootPortRemoteBread-onlycurrentNID Series card STP Bridges status: MSTI15 - Root ID
1.3.6.1.4.1.4756.20.502.20.1.1421ColumnnidMSTI15RootCostRemoteBread-onlycurrentNID Series card STP Bridges status: MSTI15 - Root Cost
1.3.6.1.4.1.4756.20.502.20.1.1422ColumnnidMSTI15TopologyFlagRemoteBread-onlycurrentNID Series card STP Bridges status: MSTI15 - Topology Flag
1.3.6.1.4.1.4756.20.502.20.1.1423ColumnnidMSTI15TopologyChangeLastRemoteBread-onlycurrentNID Series card STP Bridges status: MSTI15 - Topology Change Last
1.3.6.1.4.1.4756.20.502.20.1.1424ColumnnidSTPPortStatusInst1PortRemoteBread-onlycurrentNID Series card STP Port status: Instance1 - Port
1.3.6.1.4.1.4756.20.502.20.1.1425ColumnnidSTPPortStatusInst1CISTRoleRemoteBread-onlycurrentNID Series card STP Port status: Instance1 - CIST Role
1.3.6.1.4.1.4756.20.502.20.1.1426ColumnnidSTPPortStatusInst1CISTStateRemoteBread-onlycurrentNID Series card STP Port status: Instance1 - CIST State
1.3.6.1.4.1.4756.20.502.20.1.1427ColumnnidSTPPortStatusInst1UptimeRemoteBread-onlycurrentNID Series card STP Port status: Instance1 -Uptime
1.3.6.1.4.1.4756.20.502.20.1.1428ColumnnidSTPPortStatusInst2PortRemoteBread-onlycurrentNID Series card STP Port status: Instance2 - Port
1.3.6.1.4.1.4756.20.502.20.1.1429ColumnnidSTPPortStatusInst2CISTRoleRemoteBread-onlycurrentNID Series card STP Port status: Instance2 - CIST Role
1.3.6.1.4.1.4756.20.502.20.1.1430ColumnnidSTPPortStatusInst2CISTStateRemoteBread-onlycurrentNID Series card STP Port status: Instance2 - CIST State
1.3.6.1.4.1.4756.20.502.20.1.1431ColumnnidSTPPortStatusInst2UptimeRemoteBread-onlycurrentNID Series card STP Port status: Instance2 -Uptime
1.3.6.1.4.1.4756.20.502.20.1.1432ColumnnidSTPPortStatusInst3PortRemoteBread-onlycurrentNID Series card STP Port status: Instance3 - Port
1.3.6.1.4.1.4756.20.502.20.1.1433ColumnnidSTPPortStatusInst3CISTRoleRemoteBread-onlycurrentNID Series card STP Port status: Instance3 - CIST Role
1.3.6.1.4.1.4756.20.502.20.1.1434ColumnnidSTPPortStatusInst3CISTStateRemoteBread-onlycurrentNID Series card STP Port status: Instance3 - CIST State
1.3.6.1.4.1.4756.20.502.20.1.1435ColumnnidSTPPortStatusInst3UptimeRemoteBread-onlycurrentNID Series card STP Port status: Instance3 -Uptime
1.3.6.1.4.1.4756.20.502.20.1.1436ColumnnidSTPPortStatusInst4PortRemoteBread-onlycurrentNID Series card STP Port status: Instance4 - Port
1.3.6.1.4.1.4756.20.502.20.1.1437ColumnnidSTPPortStatusInst4CISTRoleRemoteBread-onlycurrentNID Series card STP Port status: Instance4 - CIST Role
1.3.6.1.4.1.4756.20.502.20.1.1438ColumnnidSTPPortStatusInst4CISTStateRemoteBread-onlycurrentNID Series card STP Port status: Instance4 - CIST State
1.3.6.1.4.1.4756.20.502.20.1.1439ColumnnidSTPPortStatusInst4UptimeRemoteBread-onlycurrentNID Series card STP Port status: Instance4 -Uptime
1.3.6.1.4.1.4756.20.502.20.1.1440ColumnnidSTPPortStatusInst5PortRemoteBread-onlycurrentNID Series card STP Port status: Instance5 - Port
1.3.6.1.4.1.4756.20.502.20.1.1441ColumnnidSTPPortStatusInst5CISTRoleRemoteBread-onlycurrentNID Series card STP Port status: Instance5 - CIST Role
1.3.6.1.4.1.4756.20.502.20.1.1442ColumnnidSTPPortStatusInst5CISTStateRemoteBread-onlycurrentNID Series card STP Port status: Instance5 - CIST State
1.3.6.1.4.1.4756.20.502.20.1.1443ColumnnidSTPPortStatusInst5UptimeRemoteBread-onlycurrentNID Series card STP Port status: Instance5 -Uptime
1.3.6.1.4.1.4756.20.502.20.1.1444ColumnnidSTPPortStatusInst6PortRemoteBread-onlycurrentNID Series card STP Port status: Instance6- Port
1.3.6.1.4.1.4756.20.502.20.1.1445ColumnnidSTPPortStatusInst6CISTRoleRemoteBread-onlycurrentNID Series card STP Port status: Instance6- CIST Role
1.3.6.1.4.1.4756.20.502.20.1.1446ColumnnidSTPPortStatusInst6CISTStateRemoteBread-onlycurrentNID Series card STP Port status: Instance6- CIST State
1.3.6.1.4.1.4756.20.502.20.1.1447ColumnnidSTPPortStatusInst6UptimeRemoteBread-onlycurrentNID Series card STP Port status: Instance6-Uptime
1.3.6.1.4.1.4756.20.502.20.1.1448ColumnnidSTPPortStatusInst7PortRemoteBread-onlycurrentNID Series card STP Port status: Instance7- Port
1.3.6.1.4.1.4756.20.502.20.1.1449ColumnnidSTPPortStatusInst7CISTRoleRemoteBread-onlycurrentNID Series card STP Port status: Instance7- CIST Role
1.3.6.1.4.1.4756.20.502.20.1.1450ColumnnidSTPPortStatusInst7CISTStateRemoteBread-onlycurrentNID Series card STP Port status: Instance7- CIST State
1.3.6.1.4.1.4756.20.502.20.1.1451ColumnnidSTPPortStatusInst7UptimeRemoteBread-onlycurrentNID Series card STP Port status: Instance7-Uptime
1.3.6.1.4.1.4756.20.502.20.1.1452ColumnnidSTPPortStatusInst8PortRemoteBread-onlycurrentNID Series card STP Port status: Instance8- Port
1.3.6.1.4.1.4756.20.502.20.1.1453ColumnnidSTPPortStatusInst8CISTRoleRemoteBread-onlycurrentNID Series card STP Port status: Instance8- CIST Role
1.3.6.1.4.1.4756.20.502.20.1.1454ColumnnidSTPPortStatusInst8CISTStateRemoteBread-onlycurrentNID Series card STP Port status: Instance8- CIST State
1.3.6.1.4.1.4756.20.502.20.1.1455ColumnnidSTPPortStatusInst8UptimeRemoteBread-onlycurrentNID Series card STP Port status: Instance8-Uptime
1.3.6.1.4.1.4756.20.502.20.1.1456ColumnnidSTPStatisticsPort1TxMSTPRemoteBread-onlycurrentNID Series card STP Port Statistics: Port1 -Transmitted MSTP
1.3.6.1.4.1.4756.20.502.20.1.1457ColumnnidSTPStatisticsPort1TxRSTPRemoteBread-onlycurrentNID Series card STP Port Statistics: Port1 -Transmitted RSTP
1.3.6.1.4.1.4756.20.502.20.1.1458ColumnnidSTPStatisticsPort1TxSTPRemoteBread-onlycurrentNID Series card STP Port Statistics: Port1 -Transmitted RSTP
1.3.6.1.4.1.4756.20.502.20.1.1459ColumnnidSTPStatisticsPort1TxTCNRemoteBread-onlycurrentNID Series card STP Port Statistics: Port1 -Transmitted RSTP
1.3.6.1.4.1.4756.20.502.20.1.1460ColumnnidSTPStatisticsPort1RxMSTPRemoteBread-onlycurrentNID Series card STP Port Statistics: Port1 -Received MSTP
1.3.6.1.4.1.4756.20.502.20.1.1461ColumnnidSTPStatisticsPort1RxRSTPRemoteBread-onlycurrentNID Series card STP Port Statistics: Port1 -Received RSTP
1.3.6.1.4.1.4756.20.502.20.1.1462ColumnnidSTPStatisticsPort1RxSTPRemoteBread-onlycurrentNID Series card STP Port Statistics: Port1 -Received RSTP
1.3.6.1.4.1.4756.20.502.20.1.1463ColumnnidSTPStatisticsPort1RxTCNRemoteBread-onlycurrentNID Series card STP Port Statistics: Port1 -Received RSTP
1.3.6.1.4.1.4756.20.502.20.1.1464ColumnnidSTPStatisticsPort1DiscardUnknowRemoteBread-onlycurrentNID Series card STP Port Statistics: Port1 -Discarded Unknown
1.3.6.1.4.1.4756.20.502.20.1.1465ColumnnidSTPStatisticsPort1DiscardIllegalRemoteBread-onlycurrentNID Series card STP Port Statistics: Port1 -Discarded Illegal
1.3.6.1.4.1.4756.20.502.20.1.1466ColumnnidSTPStatisticsPort2TxMSTPRemoteBread-onlycurrentNID Series card STP Port Statistics: Port2 -Transmitted MSTP
1.3.6.1.4.1.4756.20.502.20.1.1467ColumnnidSTPStatisticsPort2TxRSTPRemoteBread-onlycurrentNID Series card STP Port Statistics: Port2 -Transmitted RSTP
1.3.6.1.4.1.4756.20.502.20.1.1468ColumnnidSTPStatisticsPort2TxSTPRemoteBread-onlycurrentNID Series card STP Port Statistics: Port2 -Transmitted RSTP
1.3.6.1.4.1.4756.20.502.20.1.1469ColumnnidSTPStatisticsPort2TxTCNRemoteBread-onlycurrentNID Series card STP Port Statistics: Port2 -Transmitted RSTP
1.3.6.1.4.1.4756.20.502.20.1.1470ColumnnidSTPStatisticsPort2RxMSTPRemoteBread-onlycurrentNID Series card STP Port Statistics: Port2 -Received MSTP
1.3.6.1.4.1.4756.20.502.20.1.1471ColumnnidSTPStatisticsPort2RxRSTPRemoteBread-onlycurrentNID Series card STP Port Statistics: Port1 -Received RSTP
1.3.6.1.4.1.4756.20.502.20.1.1472ColumnnidSTPStatisticsPort2RxSTPRemoteBread-onlycurrentNID Series card STP Port Statistics: Port2 -Received RSTP
1.3.6.1.4.1.4756.20.502.20.1.1473ColumnnidSTPStatisticsPort2RxTCNRemoteBread-onlycurrentNID Series card STP Port Statistics: Port2 -Received RSTP
1.3.6.1.4.1.4756.20.502.20.1.1474ColumnnidSTPStatisticsPort2DiscardUnknowRemoteBread-onlycurrentNID Series card STP Port Statistics: Port2 -Discarded Unknown
1.3.6.1.4.1.4756.20.502.20.1.1475ColumnnidSTPStatisticsPort2DiscardIllegalRemoteBread-onlycurrentNID Series card STP Port Statistics: Port2 -Discarded Illegal
1.3.6.1.4.1.4756.20.502.20.1.1476ColumnnidSTPStatisticsPort3TxMSTPRemoteBread-onlycurrentNID Series card STP Port Statistics: Port3 -Transmitted MSTP
1.3.6.1.4.1.4756.20.502.20.1.1477ColumnnidSTPStatisticsPort3TxRSTPRemoteBread-onlycurrentNID Series card STP Port Statistics: Port3 -Transmitted RSTP
1.3.6.1.4.1.4756.20.502.20.1.1478ColumnnidSTPStatisticsPort3TxSTPRemoteBread-onlycurrentNID Series card STP Port Statistics: Port3 -Transmitted RSTP
1.3.6.1.4.1.4756.20.502.20.1.1479ColumnnidSTPStatisticsPort3TxTCNRemoteBread-onlycurrentNID Series card STP Port Statistics: Port3 -Transmitted RSTP
1.3.6.1.4.1.4756.20.502.20.1.1480ColumnnidSTPStatisticsPort3RxMSTPRemoteBread-onlycurrentNID Series card STP Port Statistics: Port3 -Received MSTP
1.3.6.1.4.1.4756.20.502.20.1.1481ColumnnidSTPStatisticsPort3RxRSTPRemoteBread-onlycurrentNID Series card STP Port Statistics: Port3 -Received RSTP
1.3.6.1.4.1.4756.20.502.20.1.1482ColumnnidSTPStatisticsPort3RxSTPRemoteBread-onlycurrentNID Series card STP Port Statistics: Port3 -Received RSTP
1.3.6.1.4.1.4756.20.502.20.1.1483ColumnnidSTPStatisticsPort3RxTCNRemoteBread-onlycurrentNID Series card STP Port Statistics: Port3 -Received RSTP
1.3.6.1.4.1.4756.20.502.20.1.1484ColumnnidSTPStatisticsPort3DiscardUnknowRemoteBread-onlycurrentNID Series card STP Port Statistics: Port3 -Discarded Unknown
1.3.6.1.4.1.4756.20.502.20.1.1485ColumnnidSTPStatisticsPort3DiscardIllegalRemoteBread-onlycurrentNID Series card STP Port Statistics: Port3 -Discarded Illegal
1.3.6.1.4.1.4756.20.502.20.1.1486ColumnnidSTPStatisticsPort4TxMSTPRemoteBread-onlycurrentNID Series card STP Port Statistics: Port4 -Transmitted MSTP
1.3.6.1.4.1.4756.20.502.20.1.1487ColumnnidSTPStatisticsPort4TxRSTPRemoteBread-onlycurrentNID Series card STP Port Statistics: Port4 -Transmitted RSTP
1.3.6.1.4.1.4756.20.502.20.1.1488ColumnnidSTPStatisticsPort4TxSTPRemoteBread-onlycurrentNID Series card STP Port Statistics: Port4 -Transmitted RSTP
1.3.6.1.4.1.4756.20.502.20.1.1489ColumnnidSTPStatisticsPort4TxTCNRemoteBread-onlycurrentNID Series card STP Port Statistics: Port4 -Transmitted RSTP
1.3.6.1.4.1.4756.20.502.20.1.1490ColumnnidSTPStatisticsPort4RxMSTPRemoteBread-onlycurrentNID Series card STP Port Statistics: Port4 -Received MSTP
1.3.6.1.4.1.4756.20.502.20.1.1491ColumnnidSTPStatisticsPort4RxRSTPRemoteBread-onlycurrentNID Series card STP Port Statistics: Port4 -Received RSTP
1.3.6.1.4.1.4756.20.502.20.1.1492ColumnnidSTPStatisticsPort4RxSTPRemoteBread-onlycurrentNID Series card STP Port Statistics: Port4 -Received RSTP
1.3.6.1.4.1.4756.20.502.20.1.1493ColumnnidSTPStatisticsPort4RxTCNRemoteBread-onlycurrentNID Series card STP Port Statistics: Port4 -Received RSTP
1.3.6.1.4.1.4756.20.502.20.1.1494ColumnnidSTPStatisticsPort4DiscardUnknowRemoteBread-onlycurrentNID Series card STP Port Statistics: Port4 -Discarded Unknown
1.3.6.1.4.1.4756.20.502.20.1.1495ColumnnidSTPStatisticsPort4DiscardIllegalRemoteBread-onlycurrentNID Series card STP Port Statistics: Port4 -Discarded Illegal
1.3.6.1.4.1.4756.20.502.20.1.1496ColumnnidSTPStatisticsPort5TxMSTPRemoteBread-onlycurrentNID Series card STP Port Statistics: Port5 -Transmitted MSTP
1.3.6.1.4.1.4756.20.502.20.1.1497ColumnnidSTPStatisticsPort5TxRSTPRemoteBread-onlycurrentNID Series card STP Port Statistics: Port5 -Transmitted RSTP
1.3.6.1.4.1.4756.20.502.20.1.1498ColumnnidSTPStatisticsPort5TxSTPRemoteBread-onlycurrentNID Series card STP Port Statistics: Port5 -Transmitted RSTP
1.3.6.1.4.1.4756.20.502.20.1.1499ColumnnidSTPStatisticsPort5TxTCNRemoteBread-onlycurrentNID Series card STP Port Statistics: Port5 -Transmitted RSTP
1.3.6.1.4.1.4756.20.502.20.1.1500ColumnnidSTPStatisticsPort5RxMSTPRemoteBread-onlycurrentNID Series card STP Port Statistics: Port5 -Received MSTP
1.3.6.1.4.1.4756.20.502.20.1.1501ColumnnidSTPStatisticsPort5RxRSTPRemoteBread-onlycurrentNID Series card STP Port Statistics: Port5 -Received RSTP
1.3.6.1.4.1.4756.20.502.20.1.1502ColumnnidSTPStatisticsPort5RxSTPRemoteBread-onlycurrentNID Series card STP Port Statistics: Port5 -Received RSTP
1.3.6.1.4.1.4756.20.502.20.1.1503ColumnnidSTPStatisticsPort5RxTCNRemoteBread-onlycurrentNID Series card STP Port Statistics: Port5 -Received RSTP
1.3.6.1.4.1.4756.20.502.20.1.1504ColumnnidSTPStatisticsPort5DiscardUnknowRemoteBread-onlycurrentNID Series card STP Port Statistics: Port5 -Discarded Unknown
1.3.6.1.4.1.4756.20.502.20.1.1505ColumnnidSTPStatisticsPort5DiscardIllegalRemoteBread-onlycurrentNID Series card STP Port Statistics: Port5 -Discarded Illegal
1.3.6.1.4.1.4756.20.502.20.1.1506ColumnnidSTPStatisticsPort6TxMSTPRemoteBread-onlycurrentNID Series card STP Port Statistics: Port6 -Transmitted MSTP
1.3.6.1.4.1.4756.20.502.20.1.1507ColumnnidSTPStatisticsPort6TxRSTPRemoteBread-onlycurrentNID Series card STP Port Statistics: Port6 -Transmitted RSTP
1.3.6.1.4.1.4756.20.502.20.1.1508ColumnnidSTPStatisticsPort6TxSTPRemoteBread-onlycurrentNID Series card STP Port Statistics: Port6 -Transmitted RSTP
1.3.6.1.4.1.4756.20.502.20.1.1509ColumnnidSTPStatisticsPort6TxTCNRemoteBread-onlycurrentNID Series card STP Port Statistics: Port6 -Transmitted RSTP
1.3.6.1.4.1.4756.20.502.20.1.1510ColumnnidSTPStatisticsPort6RxMSTPRemoteBread-onlycurrentNID Series card STP Port Statistics: Port6 -Received MSTP
1.3.6.1.4.1.4756.20.502.20.1.1511ColumnnidSTPStatisticsPort6RxRSTPRemoteBread-onlycurrentNID Series card STP Port Statistics: Port6 -Received RSTP
1.3.6.1.4.1.4756.20.502.20.1.1512ColumnnidSTPStatisticsPort6RxSTPRemoteBread-onlycurrentNID Series card STP Port Statistics: Port6 -Received RSTP
1.3.6.1.4.1.4756.20.502.20.1.1513ColumnnidSTPStatisticsPort6RxTCNRemoteBread-onlycurrentNID Series card STP Port Statistics: Port6 -Received RSTP
1.3.6.1.4.1.4756.20.502.20.1.1514ColumnnidSTPStatisticsPort6DiscardUnknowRemoteBread-onlycurrentNID Series card STP Port Statistics: Port6 -Discarded Unknown
1.3.6.1.4.1.4756.20.502.20.1.1515ColumnnidSTPStatisticsPort6DiscardIllegalRemoteBread-onlycurrentNID Series card STP Port Statistics: Port6 -Discarded Illegal
1.3.6.1.4.1.4756.20.502.20.1.1516ColumnnidSTPStatisticsPort7TxMSTPRemoteBread-onlycurrentNID Series card STP Port Statistics: Port7 -Transmitted MSTP
1.3.6.1.4.1.4756.20.502.20.1.1517ColumnnidSTPStatisticsPort7TxRSTPRemoteBread-onlycurrentNID Series card STP Port Statistics: Port7 -Transmitted RSTP
1.3.6.1.4.1.4756.20.502.20.1.1518ColumnnidSTPStatisticsPort7TxSTPRemoteBread-onlycurrentNID Series card STP Port Statistics: Port7 -Transmitted RSTP
1.3.6.1.4.1.4756.20.502.20.1.1519ColumnnidSTPStatisticsPort7TxTCNRemoteBread-onlycurrentNID Series card STP Port Statistics: Port7 -Transmitted RSTP
1.3.6.1.4.1.4756.20.502.20.1.1520ColumnnidSTPStatisticsPort7RxMSTPRemoteBread-onlycurrentNID Series card STP Port Statistics: Port7 -Received MSTP
1.3.6.1.4.1.4756.20.502.20.1.1521ColumnnidSTPStatisticsPort7RxRSTPRemoteBread-onlycurrentNID Series card STP Port Statistics: Port7 -Received RSTP
1.3.6.1.4.1.4756.20.502.20.1.1522ColumnnidSTPStatisticsPort7RxSTPRemoteBread-onlycurrentNID Series card STP Port Statistics: Port7 -Received RSTP
1.3.6.1.4.1.4756.20.502.20.1.1523ColumnnidSTPStatisticsPort7RxTCNRemoteBread-onlycurrentNID Series card STP Port Statistics: Port7 -Received RSTP
1.3.6.1.4.1.4756.20.502.20.1.1524ColumnnidSTPStatisticsPort7DiscardUnknowRemoteBread-onlycurrentNID Series card STP Port Statistics: Port7 -Discarded Unknown
1.3.6.1.4.1.4756.20.502.20.1.1525ColumnnidSTPStatisticsPort7DiscardIllegalRemoteBread-onlycurrentNID Series card STP Port Statistics: Port7 -Discarded Illegal
1.3.6.1.4.1.4756.20.502.20.1.1526ColumnnidSTPStatisticsPort8TxMSTPRemoteBread-onlycurrentNID Series card STP Port Statistics: Port8 -Transmitted MSTP
1.3.6.1.4.1.4756.20.502.20.1.1527ColumnnidSTPStatisticsPort8TxRSTPRemoteBread-onlycurrentNID Series card STP Port Statistics: Port8 -Transmitted RSTP
1.3.6.1.4.1.4756.20.502.20.1.1528ColumnnidSTPStatisticsPort8TxSTPRemoteBread-onlycurrentNID Series card STP Port Statistics: Port8 -Transmitted RSTP
1.3.6.1.4.1.4756.20.502.20.1.1529ColumnnidSTPStatisticsPort8TxTCNRemoteBread-onlycurrentNID Series card STP Port Statistics: Port8 -Transmitted RSTP
1.3.6.1.4.1.4756.20.502.20.1.1530ColumnnidSTPStatisticsPort8RxMSTPRemoteBread-onlycurrentNID Series card STP Port Statistics: Port8 -Received MSTP
1.3.6.1.4.1.4756.20.502.20.1.1531ColumnnidSTPStatisticsPort8RxRSTPRemoteBread-onlycurrentNID Series card STP Port Statistics: Port8 -Received RSTP
1.3.6.1.4.1.4756.20.502.20.1.1532ColumnnidSTPStatisticsPort8RxSTPRemoteBread-onlycurrentNID Series card STP Port Statistics: Port8 -Received RSTP
1.3.6.1.4.1.4756.20.502.20.1.1533ColumnnidSTPStatisticsPort8RxTCNRemoteBread-onlycurrentNID Series card STP Port Statistics: Port8 -Received RSTP
1.3.6.1.4.1.4756.20.502.20.1.1534ColumnnidSTPStatisticsPort8DiscardUnknowRemoteBread-onlycurrentNID Series card STP Port Statistics: Port8 -Discarded Unknown
1.3.6.1.4.1.4756.20.502.20.1.1535ColumnnidSTPStatisticsPort8DiscardIllegalRemoteBread-onlycurrentNID Series card STP Port Statistics: Port8 -Discarded Illegal
1.3.6.1.4.1.4756.20.502.20.1.1536ColumnnidAllowedAccessVLANsRemoteBread-writecurrentNID Series card Global VLAN Configuration: Allowed Access VLANs By default, only VLAN 1 is enabled. More VLANs may be created by using a list syntax where the …
1.3.6.1.4.1.4756.20.502.20.1.1537ColumnnidVlanEthertypeRemoteBread-writecurrentNID Series card Global VLAN Configuration: Ethertype for Custom S-ports The format of 'Ethernet Type' is restricted to 0x600-0xFFFF
1.3.6.1.4.1.4756.20.502.20.1.1538ColumnnidPort1VlanModeRemoteBread-writecurrentNID Series card Port VLAN Configuration : Port1 - Mode 0: Access 1: Trunk 2: Hybrid
1.3.6.1.4.1.4756.20.502.20.1.1539ColumnnidPort1VlanIDRemoteBread-writecurrentNID Series card Port VLAN Configuration : Port1 - VLAN ID
1.3.6.1.4.1.4756.20.502.20.1.1540ColumnnidPort1VlanTypeRemoteBread-writecurrentNID Series card Port VLAN Configuration : Port1 - VLAN Type 0: Unaware 1: C-port 2: S-port 3: S-custom-port
1.3.6.1.4.1.4756.20.502.20.1.1541ColumnnidPort1VlanIngressFilteringRemoteBread-writecurrentNID Series card Port VLAN Configuration : Port1 - Ingress Filtering 0: Off 1: On
1.3.6.1.4.1.4756.20.502.20.1.1542ColumnnidPort1VlanIngressAcceptanceRemoteBread-writecurrentNID Series card Port VLAN Configuration : Port1 - Ingress Acceptance 0: Tagged and untagged 1: Tagged only 2: Untagged only
1.3.6.1.4.1.4756.20.502.20.1.1543ColumnnidPort1VlanEgressTaggingRemoteBread-writecurrentNID Series card Port VLAN Configuration : Port1 - Egress Tagging 0: Untag port vlan 1: Tag all 2: Untag all
1.3.6.1.4.1.4756.20.502.20.1.1544ColumnnidPort1AllowedVLANSRemoteBread-writecurrentNID Series card Global VLAN Configuration: Port1 - Allowed VLANs By default, only VLAN 1 is enabled. More VLANs may be created by using a list syntax where the…
1.3.6.1.4.1.4756.20.502.20.1.1545ColumnnidPort1ForbiddenVLANSRemoteBread-writecurrentNID Series card Global VLAN Configuration: Port1 - Forbidden VLANs By default, the field is left blank, which means that the port may become a member of all po…
1.3.6.1.4.1.4756.20.502.20.1.1546ColumnnidPort2VlanModeRemoteBread-writecurrentNID Series card Port VLAN Configuration : Port2 - Mode 0: Access 1: Trunk 2: Hybrid
1.3.6.1.4.1.4756.20.502.20.1.1547ColumnnidPort2VlanIDRemoteBread-writecurrentNID Series card Port VLAN Configuration : Port2 - VLAN ID
1.3.6.1.4.1.4756.20.502.20.1.1548ColumnnidPort2VlanTypeRemoteBread-writecurrentNID Series card Port VLAN Configuration : Port2 - VLAN Type 0: Unaware 1: C-port 2: S-port 3: S-custom-port
1.3.6.1.4.1.4756.20.502.20.1.1549ColumnnidPort2VlanIngressFilteringRemoteBread-writecurrentNID Series card Port VLAN Configuration : Port2 - Ingress Filtering 0: Off 1: On
1.3.6.1.4.1.4756.20.502.20.1.1550ColumnnidPort2VlanIngressAcceptanceRemoteBread-writecurrentNID Series card Port VLAN Configuration : Por2 - Ingress Acceptance 0: Tagged and untagged 1: Tagged only 2: Untagged only
1.3.6.1.4.1.4756.20.502.20.1.1551ColumnnidPort2VlanEgressTaggingRemoteBread-writecurrentNID Series card Port VLAN Configuration : Port2 - Egress Tagging 0: Untag port vlan 1: Tag all 2: Untag all
1.3.6.1.4.1.4756.20.502.20.1.1552ColumnnidPort2AllowedVLANSRemoteBread-writecurrentNID Series card Global VLAN Configuration: Port2 - Allowed VLANs By default, only VLAN 1 is enabled. More VLANs may be created by using a list syntax where the…
1.3.6.1.4.1.4756.20.502.20.1.1553ColumnnidPort2ForbiddenVLANSRemoteBread-writecurrentNID Series card Global VLAN Configuration: Port2 - Forbidden VLANs By default, the field is left blank, which means that the port may become a member of all po…
1.3.6.1.4.1.4756.20.502.20.1.1554ColumnnidPort3VlanModeRemoteBread-writecurrentNID Series card Port VLAN Configuration : Port3 - Mode 0: Access 1: Trunk 2: Hybrid
1.3.6.1.4.1.4756.20.502.20.1.1555ColumnnidPort3VlanIDRemoteBread-writecurrentNID Series card Port VLAN Configuration : Port3 - VLAN ID
1.3.6.1.4.1.4756.20.502.20.1.1556ColumnnidPort3VlanTypeRemoteBread-writecurrentNID Series card Port VLAN Configuration : Port3 - VLAN Type 0: Unaware 1: C-port 2: S-port 3: S-custom-port
1.3.6.1.4.1.4756.20.502.20.1.1557ColumnnidPort3VlanIngressFilteringRemoteBread-writecurrentNID Series card Port VLAN Configuration : Port3 - Ingress Filtering 0: Off 1: On
1.3.6.1.4.1.4756.20.502.20.1.1558ColumnnidPort3VlanIngressAcceptanceRemoteBread-writecurrentNID Series card Port VLAN Configuration : Port3 - Ingress Acceptance 0: Tagged and untagged 1: Tagged only 2: Untagged only
1.3.6.1.4.1.4756.20.502.20.1.1559ColumnnidPort3VlanEgressTaggingRemoteBread-writecurrentNID Series card Port VLAN Configuration : Port3 - Egress Tagging 0: Untag port vlan 1: Tag all 2: Untag all
1.3.6.1.4.1.4756.20.502.20.1.1560ColumnnidPort3AllowedVLANSRemoteBread-writecurrentNID Series card Global VLAN Configuration: Port3 - Allowed VLANs By default, only VLAN 1 is enabled. More VLANs may be created by using a list syntax where the…
1.3.6.1.4.1.4756.20.502.20.1.1561ColumnnidPort3ForbiddenVLANSRemoteBread-writecurrentNID Series card Global VLAN Configuration: Port3 - Forbidden VLANs By default, the field is left blank, which means that the port may become a member of all po…
1.3.6.1.4.1.4756.20.502.20.1.1562ColumnnidPort4VlanModeRemoteBread-writecurrentNID Series card Port VLAN Configuration : Port4 - Mode 0: Access 1: Trunk 2: Hybrid
1.3.6.1.4.1.4756.20.502.20.1.1563ColumnnidPort4VlanIDRemoteBread-writecurrentNID Series card Port VLAN Configuration : Port4 - VLAN ID
1.3.6.1.4.1.4756.20.502.20.1.1564ColumnnidPort4VlanTypeRemoteBread-writecurrentNID Series card Port VLAN Configuration : Port4 - VLAN Type 0: Unaware 1: C-port 2: S-port 3: S-custom-port
1.3.6.1.4.1.4756.20.502.20.1.1565ColumnnidPort4VlanIngressFilteringRemoteBread-writecurrentNID Series card Port VLAN Configuration : Port4 - Ingress Filtering 0: Off 1: On
1.3.6.1.4.1.4756.20.502.20.1.1566ColumnnidPort4VlanIngressAcceptanceRemoteBread-writecurrentNID Series card Port VLAN Configuration : Port4 - Ingress Acceptance 0: Tagged and untagged 1: Tagged only 2: Untagged only
1.3.6.1.4.1.4756.20.502.20.1.1567ColumnnidPort4VlanEgressTaggingRemoteBread-writecurrentNID Series card Port VLAN Configuration : Port4 - Egress Tagging 0: Untag port vlan 1: Tag all 2: Untag all
1.3.6.1.4.1.4756.20.502.20.1.1568ColumnnidPort4AllowedVLANSRemoteBread-writecurrentNID Series card Global VLAN Configuration: Port4 - Allowed VLANs By default, only VLAN 1 is enabled. More VLANs may be created by using a list syntax where the…
1.3.6.1.4.1.4756.20.502.20.1.1569ColumnnidPort4ForbiddenVLANSRemoteBread-writecurrentNID Series card Global VLAN Configuration: Port4 - Forbidden VLANs By default, the field is left blank, which means that the port may become a member of all po…
1.3.6.1.4.1.4756.20.502.20.1.1570ColumnnidPort5VlanModeRemoteBread-writecurrentNID Series card Port VLAN Configuration : Port5 - Mode 0: Access 1: Trunk 2: Hybrid
1.3.6.1.4.1.4756.20.502.20.1.1571ColumnnidPort5VlanIDRemoteBread-writecurrentNID Series card Port VLAN Configuration : Port5 - VLAN ID
1.3.6.1.4.1.4756.20.502.20.1.1572ColumnnidPort5VlanTypeRemoteBread-writecurrentNID Series card Port VLAN Configuration : Port5 - VLAN Type 0: Unaware 1: C-port 2: S-port 3: S-custom-port
1.3.6.1.4.1.4756.20.502.20.1.1573ColumnnidPort5VlanIngressFilteringRemoteBread-writecurrentNID Series card Port VLAN Configuration : Port5 - Ingress Filtering 0: Off 1: On
1.3.6.1.4.1.4756.20.502.20.1.1574ColumnnidPort5VlanIngressAcceptanceRemoteBread-writecurrentNID Series card Port VLAN Configuration : Port5 - Ingress Acceptance 0: Tagged and untagged 1: Tagged only 2: Untagged only
1.3.6.1.4.1.4756.20.502.20.1.1575ColumnnidPort5VlanEgressTaggingRemoteBread-writecurrentNID Series card Port VLAN Configuration : Port5 - Egress Tagging 0: Untag port vlan 1: Tag all 2: Untag all
1.3.6.1.4.1.4756.20.502.20.1.1576ColumnnidPort5AllowedVLANSRemoteBread-writecurrentNID Series card Global VLAN Configuration: Port5 - Allowed VLANs By default, only VLAN 1 is enabled. More VLANs may be created by using a list syntax where the…
1.3.6.1.4.1.4756.20.502.20.1.1577ColumnnidPort5ForbiddenVLANSRemoteBread-writecurrentNID Series card Global VLAN Configuration: Port5 - Forbidden VLANs By default, the field is left blank, which means that the port may become a member of all po…
1.3.6.1.4.1.4756.20.502.20.1.1578ColumnnidPort6VlanModeRemoteBread-writecurrentNID Series card Port VLAN Configuration : Port6 - Mode 0: Access 1: Trunk 2: Hybrid
1.3.6.1.4.1.4756.20.502.20.1.1579ColumnnidPort6VlanIDRemoteBread-writecurrentNID Series card Port VLAN Configuration : Port6 - VLAN ID
1.3.6.1.4.1.4756.20.502.20.1.1580ColumnnidPort6VlanTypeRemoteBread-writecurrentNID Series card Port VLAN Configuration : Port6 - VLAN Type 0: Unaware 1: C-port 2: S-port 3: S-custom-port
1.3.6.1.4.1.4756.20.502.20.1.1581ColumnnidPort6VlanIngressFilteringRemoteBread-writecurrentNID Series card Port VLAN Configuration : Port6 - Ingress Filtering 0: Off 1: On
1.3.6.1.4.1.4756.20.502.20.1.1582ColumnnidPort6VlanIngressAcceptanceRemoteBread-writecurrentNID Series card Port VLAN Configuration : Port6 - Ingress Acceptance 0: Tagged and untagged 1: Tagged only 2: Untagged only
1.3.6.1.4.1.4756.20.502.20.1.1583ColumnnidPort6VlanEgressTaggingRemoteBread-writecurrentNID Series card Port VLAN Configuration : Port6 - Egress Tagging 0: Untag port vlan 1: Tag all 2: Untag all
1.3.6.1.4.1.4756.20.502.20.1.1584ColumnnidPort6AllowedVLANSRemoteBread-writecurrentNID Series card Global VLAN Configuration: Port6 - Allowed VLANs By default, only VLAN 1 is enabled. More VLANs may be created by using a list syntax where the…
1.3.6.1.4.1.4756.20.502.20.1.1585ColumnnidPort6ForbiddenVLANSRemoteBread-writecurrentNID Series card Global VLAN Configuration: Port6 - Forbidden VLANs By default, the field is left blank, which means that the port may become a member of all po…
1.3.6.1.4.1.4756.20.502.20.1.1586ColumnnidPort7VlanModeRemoteBread-writecurrentNID Series card Port VLAN Configuration : Port7 - Mode 0: Access 1: Trunk 2: Hybrid
1.3.6.1.4.1.4756.20.502.20.1.1587ColumnnidPort7VlanIDRemoteBread-writecurrentNID Series card Port VLAN Configuration : Port7 - VLAN ID
1.3.6.1.4.1.4756.20.502.20.1.1588ColumnnidPort7VlanTypeRemoteBread-writecurrentNID Series card Port VLAN Configuration : Port7 - VLAN Type 0: Unaware 1: C-port 2: S-port 3: S-custom-port
1.3.6.1.4.1.4756.20.502.20.1.1589ColumnnidPort7VlanIngressFilteringRemoteBread-writecurrentNID Series card Port VLAN Configuration : Port7 - Ingress Filtering 0: Off 1: On
1.3.6.1.4.1.4756.20.502.20.1.1590ColumnnidPort7VlanIngressAcceptanceRemoteBread-writecurrentNID Series card Port VLAN Configuration : Port7 - Ingress Acceptance 0: Tagged and untagged 1: Tagged only 2: Untagged only
1.3.6.1.4.1.4756.20.502.20.1.1591ColumnnidPort7VlanEgressTaggingRemoteBread-writecurrentNID Series card Port VLAN Configuration : Port7 - Egress Tagging 0: Untag port vlan 1: Tag all 2: Untag all
1.3.6.1.4.1.4756.20.502.20.1.1592ColumnnidPort7AllowedVLANSRemoteBread-writecurrentNID Series card Global VLAN Configuration: Port7 - Allowed VLANs By default, only VLAN 1 is enabled. More VLANs may be created by using a list syntax where the…
1.3.6.1.4.1.4756.20.502.20.1.1593ColumnnidPort7ForbiddenVLANSRemoteBread-writecurrentNID Series card Global VLAN Configuration: Port7 - Forbidden VLANs By default, the field is left blank, which means that the port may become a member of all po…
1.3.6.1.4.1.4756.20.502.20.1.1594ColumnnidPort8VlanModeRemoteBread-writecurrentNID Series card Port VLAN Configuration : Port8 - Mode 0: Access 1: Trunk 2: Hybrid
1.3.6.1.4.1.4756.20.502.20.1.1595ColumnnidPort8VlanIDRemoteBread-writecurrentNID Series card Port VLAN Configuration : Port8 - VLAN ID
1.3.6.1.4.1.4756.20.502.20.1.1596ColumnnidPort8VlanTypeRemoteBread-writecurrentNID Series card Port VLAN Configuration : Port8 - VLAN Type 0: Unaware 1: C-port 2: S-port 3: S-custom-port
1.3.6.1.4.1.4756.20.502.20.1.1597ColumnnidPort8VlanIngressFilteringRemoteBread-writecurrentNID Series card Port VLAN Configuration : Port8 - Ingress Filtering 0: Off 1: On
1.3.6.1.4.1.4756.20.502.20.1.1598ColumnnidPort8VlanIngressAcceptanceRemoteBread-writecurrentNID Series card Port VLAN Configuration : Port8 - Ingress Acceptance 0: Tagged and untagged 1: Tagged only 2: Untagged only
1.3.6.1.4.1.4756.20.502.20.1.1599ColumnnidPort8VlanEgressTaggingRemoteBread-writecurrentNID Series card Port VLAN Configuration : Port8 - Egress Tagging 0: Untag port vlan 1: Tag all 2: Untag all
1.3.6.1.4.1.4756.20.502.20.1.1600ColumnnidPort8AllowedVLANSRemoteBread-writecurrentNID Series card Global VLAN Configuration: Port8 - Allowed VLANs By default, only VLAN 1 is enabled. More VLANs may be created by using a list syntax where the…
1.3.6.1.4.1.4756.20.502.20.1.1601ColumnnidPort8ForbiddenVLANSRemoteBread-writecurrentNID Series card Global VLAN Configuration: Port8 - Forbidden VLANs By default, the field is left blank, which means that the port may become a member of all po…
1.3.6.1.4.1.4756.20.502.20.1.1602ColumnnidQOSPort1IngressRemoteBread-writecurrentNID Series card QOS Port1 Ingress Enabled 0: NO 1: YES
1.3.6.1.4.1.4756.20.502.20.1.1603ColumnnidQOSPort1IngressRateRemoteBread-writecurrentNID Series card QOS Port1 Ingress Rate
1.3.6.1.4.1.4756.20.502.20.1.1604ColumnnidQOSPort1IngressRateUnitRemoteBread-writecurrentNID Series card QOS Port1 Ingress Rate Unit 0: Kbps 1: Mbps 2: fps 3: kfps
1.3.6.1.4.1.4756.20.502.20.1.1605ColumnnidQOSPort1IngressFlowControlRemoteBread-writecurrentNID Series card QOS Port1 Ingress Flow Control 0: NO 1: YES
1.3.6.1.4.1.4756.20.502.20.1.1606ColumnnidQOSPort2IngressRemoteBread-writecurrentNID Series card QOS Port2 Ingress Enabled 0: NO 1: YES
1.3.6.1.4.1.4756.20.502.20.1.1607ColumnnidQOSPort2IngressRateRemoteBread-writecurrentNID Series card QOS Port2 Ingress Rate
1.3.6.1.4.1.4756.20.502.20.1.1608ColumnnidQOSPort2IngressRateUnitRemoteBread-writecurrentNID Series card QOS Port2 Ingress Rate Unit 0: Kbps 1: Mbps 2: fps 3: kfps
1.3.6.1.4.1.4756.20.502.20.1.1609ColumnnidQOSPort2IngressFlowControlRemoteBread-writecurrentNID Series card QOS Port2 Ingress Flow Control 0: NO 1: YES
1.3.6.1.4.1.4756.20.502.20.1.1610ColumnnidQOSPort3IngressRemoteBread-writecurrentNID Series card QOS Port3 Ingress Enabled 0: NO 1: YES
1.3.6.1.4.1.4756.20.502.20.1.1611ColumnnidQOSPort3IngressRateRemoteBread-writecurrentNID Series card QOS Port3 Ingress Rate
1.3.6.1.4.1.4756.20.502.20.1.1612ColumnnidQOSPort3IngressRateUnitRemoteBread-writecurrentNID Series card QOS Port3 Ingress Rate Unit 0: Kbps 1: Mbps 2: fps 3: kfps
1.3.6.1.4.1.4756.20.502.20.1.1613ColumnnidQOSPort3IngressFlowControlRemoteBread-writecurrentNID Series card QOS Port3 Ingress Flow Control 0: NO 1: YES
1.3.6.1.4.1.4756.20.502.20.1.1614ColumnnidQOSPort4IngressRemoteBread-writecurrentNID Series card QOS Port4 Ingress Enabled 0: NO 1: YES
1.3.6.1.4.1.4756.20.502.20.1.1615ColumnnidQOSPort4IngressRateRemoteBread-writecurrentNID Series card QOS Port4 Ingress Rate
1.3.6.1.4.1.4756.20.502.20.1.1616ColumnnidQOSPort4IngressRateUnitRemoteBread-writecurrentNID Series card QOS Port4 Ingress Rate Unit 0: Kbps 1: Mbps 2: fps 3: kfps
1.3.6.1.4.1.4756.20.502.20.1.1617ColumnnidQOSPort4IngressFlowControlRemoteBread-writecurrentNID Series card QOS Port4 Ingress Flow Control 0: NO 1: YES
1.3.6.1.4.1.4756.20.502.20.1.1618ColumnnidQOSPort5IngressRemoteBread-writecurrentNID Series card QOS Port5 Ingress Enabled 0: NO 1: YES
1.3.6.1.4.1.4756.20.502.20.1.1619ColumnnidQOSPort5IngressRateRemoteBread-writecurrentNID Series card QOS Port5 Ingress Rate
1.3.6.1.4.1.4756.20.502.20.1.1620ColumnnidQOSPort5IngressRateUnitRemoteBread-writecurrentNID Series card QOS Port5 Ingress Rate Unit 0: Kbps 1: Mbps 2: fps 3: kfps
1.3.6.1.4.1.4756.20.502.20.1.1621ColumnnidQOSPort5IngressFlowControlRemoteBread-writecurrentNID Series card QOS Port5 Ingress Flow Control 0: NO 1: YES
1.3.6.1.4.1.4756.20.502.20.1.1622ColumnnidQOSPort6IngressRemoteBread-writecurrentNID Series card QOS Port6 Ingress Enabled 0: NO 1: YES
1.3.6.1.4.1.4756.20.502.20.1.1623ColumnnidQOSPort6IngressRateRemoteBread-writecurrentNID Series card QOS Port6 Ingress Rate
1.3.6.1.4.1.4756.20.502.20.1.1624ColumnnidQOSPort6IngressRateUnitRemoteBread-writecurrentNID Series card QOS Port6 Ingress Rate Unit 0: Kbps 1: Mbps 2: fps 3: kfps
1.3.6.1.4.1.4756.20.502.20.1.1625ColumnnidQOSPort6IngressFlowControlRemoteBread-writecurrentNID Series card QOS Port6 Ingress Flow Control 0: NO 1: YES
1.3.6.1.4.1.4756.20.502.20.1.1626ColumnnidQOSPort7IngressRemoteBread-writecurrentNID Series card QOS Port7 Ingress Enabled 0: NO 1: YES
1.3.6.1.4.1.4756.20.502.20.1.1627ColumnnidQOSPort7IngressRateRemoteBread-writecurrentNID Series card QOS Port7 Ingress Rate
1.3.6.1.4.1.4756.20.502.20.1.1628ColumnnidQOSPort7IngressRateUnitRemoteBread-writecurrentNID Series card QOS Port7 Ingress Rate Unit 0: Kbps 1: Mbps 2: fps 3: kfps
1.3.6.1.4.1.4756.20.502.20.1.1629ColumnnidQOSPort7IngressFlowControlRemoteBread-writecurrentNID Series card QOS Port7 Ingress Flow Control 0: NO 1: YES
1.3.6.1.4.1.4756.20.502.20.1.1630ColumnnidQOSPort8IngressRemoteBread-writecurrentNID Series card QOS Port8 Ingress Enabled 0: NO 1: YES
1.3.6.1.4.1.4756.20.502.20.1.1631ColumnnidQOSPort8IngressRateRemoteBread-writecurrentNID Series card QOS Port8 Ingress Rate
1.3.6.1.4.1.4756.20.502.20.1.1632ColumnnidQOSPort8IngressRateUnitRemoteBread-writecurrentNID Series card QOS Port8 Ingress Rate Unit 0: Kbps 1: Mbps 2: fps 3: kfps
1.3.6.1.4.1.4756.20.502.20.1.1633ColumnnidQOSPort8IngressFlowControlRemoteBread-writecurrentNID Series card QOS Port8 Ingress Flow Control 0: NO 1: YES
1.3.6.1.4.1.4756.20.502.20.1.1634ColumnnidQOSPort1EgressRemoteBread-writecurrentNID Series card QOS Port1 Egress Enabled 0: NO 1: YES
1.3.6.1.4.1.4756.20.502.20.1.1635ColumnnidQOSPort1EgressRateRemoteBread-writecurrentNID Series card QOS Port1 Egress Rate
1.3.6.1.4.1.4756.20.502.20.1.1636ColumnnidQOSPort1EgressRateUnitRemoteBread-writecurrentNID Series card QOS Port1 Egress Rate Unit 0: Kbps 1: Mbps
1.3.6.1.4.1.4756.20.502.20.1.1637ColumnnidQOSPort2EgressRemoteBread-writecurrentNID Series card QOS Port2 Egress Enabled 0: NO 1: YES
1.3.6.1.4.1.4756.20.502.20.1.1638ColumnnidQOSPort2EgressRateRemoteBread-writecurrentNID Series card QOS Port2 Egress Rate
1.3.6.1.4.1.4756.20.502.20.1.1639ColumnnidQOSPort2EgressRateUnitRemoteBread-writecurrentNID Series card QOS Port2 Egress Rate Unit 0: Kbps 1: Mbps
1.3.6.1.4.1.4756.20.502.20.1.1640ColumnnidQOSPort3EgressRemoteBread-writecurrentNID Series card QOS Port3 Egress Enabled 0: NO 1: YES
1.3.6.1.4.1.4756.20.502.20.1.1641ColumnnidQOSPort3EgressRateRemoteBread-writecurrentNID Series card QOS Port3 Egress Rate
1.3.6.1.4.1.4756.20.502.20.1.1642ColumnnidQOSPort3EgressRateUnitRemoteBread-writecurrentNID Series card QOS Port3 Egress Rate Unit 0: Kbps 1: Mbps
1.3.6.1.4.1.4756.20.502.20.1.1643ColumnnidQOSPort4EgressRemoteBread-writecurrentNID Series card QOS Port4 Egress Enabled 0: NO 1: YES
1.3.6.1.4.1.4756.20.502.20.1.1644ColumnnidQOSPort4EgressRateRemoteBread-writecurrentNID Series card QOS Port4 Egress Rate
1.3.6.1.4.1.4756.20.502.20.1.1645ColumnnidQOSPort4EgressRateUnitRemoteBread-writecurrentNID Series card QOS Port4 Egress Rate Unit 0: Kbps 1: Mbps
1.3.6.1.4.1.4756.20.502.20.1.1646ColumnnidQOSPort5EgressRemoteBread-writecurrentNID Series card QOS Port5 Egress Enabled 0: NO 1: YES
1.3.6.1.4.1.4756.20.502.20.1.1647ColumnnidQOSPort5EgressRateRemoteBread-writecurrentNID Series card QOS Port5 Egress Rate
1.3.6.1.4.1.4756.20.502.20.1.1648ColumnnidQOSPort5EgressRateUnitRemoteBread-writecurrentNID Series card QOS Port5 Egress Rate Unit 0: Kbps 1: Mbps
1.3.6.1.4.1.4756.20.502.20.1.1649ColumnnidQOSPort6EgressRemoteBread-writecurrentNID Series card QOS Port6 Egress Enabled 0: NO 1: YES
1.3.6.1.4.1.4756.20.502.20.1.1650ColumnnidQOSPort6EgressRateRemoteBread-writecurrentNID Series card QOS Port6 Egress Rate
1.3.6.1.4.1.4756.20.502.20.1.1651ColumnnidQOSPort6EgressRateUnitRemoteBread-writecurrentNID Series card QOS Port6 Egress Rate Unit 0: Kbps 1: Mbps
1.3.6.1.4.1.4756.20.502.20.1.1652ColumnnidQOSPort7EgressRemoteBread-writecurrentNID Series card QOS Port7 Egress Enabled 0: NO 1: YES
1.3.6.1.4.1.4756.20.502.20.1.1653ColumnnidQOSPort7EgressRateRemoteBread-writecurrentNID Series card QOS Port7 Egress Rate
1.3.6.1.4.1.4756.20.502.20.1.1654ColumnnidQOSPort7EgressRateUnitRemoteBread-writecurrentNID Series card QOS Port7 Egress Rate Unit 0: Kbps 1: Mbps
1.3.6.1.4.1.4756.20.502.20.1.1655ColumnnidQOSPort8EgressRemoteBread-writecurrentNID Series card QOS Port8 Egress Enabled 0: NO 1: YES
1.3.6.1.4.1.4756.20.502.20.1.1656ColumnnidQOSPort8EgressRateRemoteBread-writecurrentNID Series card QOS Port8 Egress Rate
1.3.6.1.4.1.4756.20.502.20.1.1657ColumnnidQOSPort8EgressRateUnitRemoteBread-writecurrentNID Series card QOS Port8 Egress Rate Unit 0: Kbps 1: Mbps
1.3.6.1.4.1.4756.20.502.20.1.1658ColumnnidQOSUnicastRemoteBread-writecurrentNID Series card QOS Storm Control Configuration- Unicast 0: NO 1: YES
1.3.6.1.4.1.4756.20.502.20.1.1659ColumnnidQOSUnicastRateRemoteBread-writecurrentNID Series card QOS Storm Control Configuration- Unicast Rate The rate unit is packets per second (pps). 0: 1 1: 2 2: 4 3: 8 4: 16 5: 32 6: 64 7: 128 8: 256 9:…
1.3.6.1.4.1.4756.20.502.20.1.1660ColumnnidQOSMulticastRemoteBread-writecurrentNID Series card QOS Storm Control Configuration- Multicast 0: NO 1: YES
1.3.6.1.4.1.4756.20.502.20.1.1661ColumnnidQOSMulticastRateRemoteBread-writecurrentNID Series card QOS Storm Control Configuration- Multicast The rate unit is packets per second (pps). 0: 1 1: 2 2: 4 3: 8 4: 16 5: 32 6: 64 7: 128 8: 256 9: 51…
1.3.6.1.4.1.4756.20.502.20.1.1662ColumnnidQOSBroadcastRemoteBread-writecurrentNID Series card QOS Storm Control Configuration- Broadcast 0: NO 1: YES
1.3.6.1.4.1.4756.20.502.20.1.1663ColumnnidQOSBroadcastRateRemoteBread-writecurrentNID Series card QOS Storm Control Configuration- Broadcast The rate unit is packets per second (pps). 0: 1 1: 2 2: 4 3: 8 4: 16 5: 32 6: 64 7: 128 8: 256 9: 51…
1.3.6.1.4.1.4756.20.502.20.1.1664ColumnnidL2CPPort1DMAC0180C2000000RemoteBread-writecurrentNID Series card Port 1 L2CP Mode 0180C2000000 0: Forward 1: Discard 2: Peer
1.3.6.1.4.1.4756.20.502.20.1.1665ColumnnidL2CPPort1DMAC0180C2000001RemoteBread-writecurrentNID Series card Port 1 L2CP Mode 0180C2000001 0: Forward 1: Discard 2: Peer
1.3.6.1.4.1.4756.20.502.20.1.1666ColumnnidL2CPPort1DMAC0180C2000002RemoteBread-writecurrentNID Series card Port 1 L2CP Mode 0180C2000002 0: Forward 1: Discard 2: Peer
1.3.6.1.4.1.4756.20.502.20.1.1667ColumnnidL2CPPort1DMAC0180C2000003RemoteBread-writecurrentNID Series card Port 1 L2CP Mode 0180C2000003 0: Forward 1: Discard 2: Peer
1.3.6.1.4.1.4756.20.502.20.1.1668ColumnnidL2CPPort1DMAC0180C2000004RemoteBread-writecurrentNID Series card Port 1 L2CP Mode 0180C2000004 0: Forward 1: Discard 2: Peer
1.3.6.1.4.1.4756.20.502.20.1.1669ColumnnidL2CPPort1DMAC0180C2000005RemoteBread-writecurrentNID Series card Port 1 L2CP Mode 0180C2000005 0: Forward 1: Discard 2: Peer
1.3.6.1.4.1.4756.20.502.20.1.1670ColumnnidL2CPPort1DMAC0180C2000006RemoteBread-writecurrentNID Series card Port 1 L2CP Mode 0180C2000006 0: Forward 1: Discard 2: Peer
1.3.6.1.4.1.4756.20.502.20.1.1671ColumnnidL2CPPort1DMAC0180C2000007RemoteBread-writecurrentNID Series card Port 1 L2CP Mode 0180C2000007 0: Forward 1: Discard 2: Peer
1.3.6.1.4.1.4756.20.502.20.1.1672ColumnnidL2CPPort1DMAC0180C2000008RemoteBread-writecurrentNID Series card Port 1 L2CP Mode 0180C2000008 0: Forward 1: Discard 2: Peer
1.3.6.1.4.1.4756.20.502.20.1.1673ColumnnidL2CPPort1DMAC0180C2000009RemoteBread-writecurrentNID Series card Port 1 L2CP Mode 0180C2000009 0: Forward 1: Discard 2: Peer
1.3.6.1.4.1.4756.20.502.20.1.1674ColumnnidL2CPPort1DMAC0180C200000ARemoteBread-writecurrentNID Series card Port 1 L2CP Mode 0180C200000A 0: Forward 1: Discard 2: Peer
1.3.6.1.4.1.4756.20.502.20.1.1675ColumnnidL2CPPort1DMAC0180C200000BRemoteBread-writecurrentNID Series card Port 1 L2CP Mode 0180C200000B 0: Forward 1: Discard 2: Peer
1.3.6.1.4.1.4756.20.502.20.1.1676ColumnnidL2CPPort1DMAC0180C200000CRemoteBread-writecurrentNID Series card Port 1 L2CP Mode 0180C200000C 0: Forward 1: Discard 2: Peer
1.3.6.1.4.1.4756.20.502.20.1.1677ColumnnidL2CPPort1DMAC0180C200000DRemoteBread-writecurrentNID Series card Port 1 L2CP Mode 0180C200000D 0: Forward 1: Discard 2: Peer
1.3.6.1.4.1.4756.20.502.20.1.1678ColumnnidL2CPPort1DMAC0180C200000ERemoteBread-writecurrentNID Series card Port 1 L2CP Mode 0180C200000E 0: Forward 1: Discard 2: Peer
1.3.6.1.4.1.4756.20.502.20.1.1679ColumnnidL2CPPort1DMAC0180C200000FRemoteBread-writecurrentNID Series card Port 1 L2CP Mode 0180C200000F 0: Forward 1: Discard 2: Peer
1.3.6.1.4.1.4756.20.502.20.1.1680ColumnnidL2CPPort1DMAC0180C2000010RemoteBread-writecurrentNID Series card Port 1 L2CP Mode 0180C2000010 0: Forward 1: Discard 2: Peer
1.3.6.1.4.1.4756.20.502.20.1.1681ColumnnidL2CPPort1DMAC0180C2000020RemoteBread-writecurrentNID Series card Port 1 L2CP Mode 0180C2000020 0: Forward 1: Discard 2: Peer
1.3.6.1.4.1.4756.20.502.20.1.1682ColumnnidL2CPPort1DMAC0180C2000021RemoteBread-writecurrentNID Series card Port 1 L2CP Mode 0180C2000021 0: Forward 1: Discard 2: Peer
1.3.6.1.4.1.4756.20.502.20.1.1683ColumnnidL2CPPort1DMAC0180C2000022RemoteBread-writecurrentNID Series card Port 1 L2CP Mode 0180C2000022 0: Forward 1: Discard 2: Peer
1.3.6.1.4.1.4756.20.502.20.1.1684ColumnnidL2CPPort1DMAC0180C2000023RemoteBread-writecurrentNID Series card Port 1 L2CP Mode 0180C2000023 0: Forward 1: Discard 2: Peer
1.3.6.1.4.1.4756.20.502.20.1.1685ColumnnidL2CPPort1DMAC0180C2000024RemoteBread-writecurrentNID Series card Port 1 L2CP Mode 0180C2000024 0: Forward 1: Discard 2: Peer
1.3.6.1.4.1.4756.20.502.20.1.1686ColumnnidL2CPPort1DMAC0180C2000025RemoteBread-writecurrentNID Series card Port 1 L2CP Mode 0180C2000025 0: Forward 1: Discard 2: Peer
1.3.6.1.4.1.4756.20.502.20.1.1687ColumnnidL2CPPort1DMAC0180C2000026RemoteBread-writecurrentNID Series card Port 1 L2CP Mode 0180C2000026 0: Forward 1: Discard 2: Peer
1.3.6.1.4.1.4756.20.502.20.1.1688ColumnnidL2CPPort1DMAC0180C2000027RemoteBread-writecurrentNID Series card Port 1 L2CP Mode 0180C2000027 0: Forward 1: Discard 2: Peer
1.3.6.1.4.1.4756.20.502.20.1.1689ColumnnidL2CPPort1DMAC0180C2000028RemoteBread-writecurrentNID Series card Port 1 L2CP Mode 0180C2000028 0: Forward 1: Discard 2: Peer
1.3.6.1.4.1.4756.20.502.20.1.1690ColumnnidL2CPPort1DMAC0180C2000029RemoteBread-writecurrentNID Series card Port 1 L2CP Mode 0180C2000029 0: Forward 1: Discard 2: Peer
1.3.6.1.4.1.4756.20.502.20.1.1691ColumnnidL2CPPort1DMAC0180C200002ARemoteBread-writecurrentNID Series card Port 1 L2CP Mode 0180C200002A 0: Forward 1: Discard 2: Peer
1.3.6.1.4.1.4756.20.502.20.1.1692ColumnnidL2CPPort1DMAC0180C200002BRemoteBread-writecurrentNID Series card Port 1 L2CP Mode 0180C200002B 0: Forward 1: Discard 2: Peer
1.3.6.1.4.1.4756.20.502.20.1.1693ColumnnidL2CPPort1DMAC0180C200002CRemoteBread-writecurrentNID Series card Port 1 L2CP Mode 0180C200002C 0: Forward 1: Discard 2: Peer
1.3.6.1.4.1.4756.20.502.20.1.1694ColumnnidL2CPPort1DMAC0180C200002DRemoteBread-writecurrentNID Series card Port 1 L2CP Mode 0180C200002D 0: Forward 1: Discard 2: Peer
1.3.6.1.4.1.4756.20.502.20.1.1695ColumnnidL2CPPort1DMAC0180C200002ERemoteBread-writecurrentNID Series card Port 1 L2CP Mode 0180C200002E 0: Forward 1: Discard 2: Peer
1.3.6.1.4.1.4756.20.502.20.1.1696ColumnnidL2CPPort1DMAC0180C200002FRemoteBread-writecurrentNID Series card Port 1 L2CP Mode 0180C200002F 0: Forward 1: Discard 1: Peer
1.3.6.1.4.1.4756.20.502.20.1.1697ColumnnidL2CPPort2DMAC0180C2000000RemoteBread-writecurrentNID Series card Port 2 L2CP Mode 0180C2000000 0: Forward 1: Discard 2: Peer
1.3.6.1.4.1.4756.20.502.20.1.1698ColumnnidL2CPPort2DMAC0180C2000001RemoteBread-writecurrentNID Series card Port 2 L2CP Mode 0180C2000001 0: Forward 1: Discard 2: Peer
1.3.6.1.4.1.4756.20.502.20.1.1699ColumnnidL2CPPort2DMAC0180C2000002RemoteBread-writecurrentNID Series card Port 2 L2CP Mode 0180C2000002 0: Forward 1: Discard 2: Peer
1.3.6.1.4.1.4756.20.502.20.1.1700ColumnnidL2CPPort2DMAC0180C2000003RemoteBread-writecurrentNID Series card Port 2 L2CP Mode 0180C2000003 0: Forward 1: Discard 2: Peer
1.3.6.1.4.1.4756.20.502.20.1.1701ColumnnidL2CPPort2DMAC0180C2000004RemoteBread-writecurrentNID Series card Port 2 L2CP Mode 0180C2000004 0: Forward 1: Discard 2: Peer
1.3.6.1.4.1.4756.20.502.20.1.1702ColumnnidL2CPPort2DMAC0180C2000005RemoteBread-writecurrentNID Series card Port 2 L2CP Mode 0180C2000005 0: Forward 1: Discard 2: Peer
1.3.6.1.4.1.4756.20.502.20.1.1703ColumnnidL2CPPort2DMAC0180C2000006RemoteBread-writecurrentNID Series card Port 2 L2CP Mode 0180C2000006 0: Forward 1: Discard 2: Peer
1.3.6.1.4.1.4756.20.502.20.1.1704ColumnnidL2CPPort2DMAC0180C2000007RemoteBread-writecurrentNID Series card Port 2 L2CP Mode 0180C2000007 0: Forward 1: Discard 2: Peer
1.3.6.1.4.1.4756.20.502.20.1.1705ColumnnidL2CPPort2DMAC0180C2000008RemoteBread-writecurrentNID Series card Port 2 L2CP Mode 0180C2000008 0: Forward 1: Discard 2: Peer
1.3.6.1.4.1.4756.20.502.20.1.1706ColumnnidL2CPPort2DMAC0180C2000009RemoteBread-writecurrentNID Series card Port 2 L2CP Mode 0180C2000009 0: Forward 1: Discard 2: Peer
1.3.6.1.4.1.4756.20.502.20.1.1707ColumnnidL2CPPort2DMAC0180C200000ARemoteBread-writecurrentNID Series card Port 2 L2CP Mode 0180C200000A 0: Forward 1: Discard 2: Peer
1.3.6.1.4.1.4756.20.502.20.1.1708ColumnnidL2CPPort2DMAC0180C200000BRemoteBread-writecurrentNID Series card Port 2 L2CP Mode 0180C200000B 0: Forward 1: Discard 2: Peer
1.3.6.1.4.1.4756.20.502.20.1.1709ColumnnidL2CPPort2DMAC0180C200000CRemoteBread-writecurrentNID Series card Port 2 L2CP Mode 0180C200000C 0: Forward 1: Discard 2: Peer
1.3.6.1.4.1.4756.20.502.20.1.1710ColumnnidL2CPPort2DMAC0180C200000DRemoteBread-writecurrentNID Series card Port 2 L2CP Mode 0180C200000D 0: Forward 1: Discard 2: Peer
1.3.6.1.4.1.4756.20.502.20.1.1711ColumnnidL2CPPort2DMAC0180C200000ERemoteBread-writecurrentNID Series card Port 2 L2CP Mode 0180C200000E 0: Forward 1: Discard 2: Peer
1.3.6.1.4.1.4756.20.502.20.1.1712ColumnnidL2CPPort2DMAC0180C200000FRemoteBread-writecurrentNID Series card Port 2 L2CP Mode 0180C200000F 0: Forward 1: Discard 2: Peer
1.3.6.1.4.1.4756.20.502.20.1.1713ColumnnidL2CPPort2DMAC0180C2000010RemoteBread-writecurrentNID Series card Port 2 L2CP Mode 0180C2000010 0: Forward 1: Discard 2: Peer
1.3.6.1.4.1.4756.20.502.20.1.1714ColumnnidL2CPPort2DMAC0180C2000020RemoteBread-writecurrentNID Series card Port 2 L2CP Mode 0180C2000020 0: Forward 1: Discard 2: Peer
1.3.6.1.4.1.4756.20.502.20.1.1715ColumnnidL2CPPort2DMAC0180C2000021RemoteBread-writecurrentNID Series card Port 2 L2CP Mode 0180C2000021 0: Forward 1: Discard 2: Peer
1.3.6.1.4.1.4756.20.502.20.1.1716ColumnnidL2CPPort2DMAC0180C2000022RemoteBread-writecurrentNID Series card Port 2 L2CP Mode 0180C2000022 0: Forward 1: Discard 2: Peer
1.3.6.1.4.1.4756.20.502.20.1.1717ColumnnidL2CPPort2DMAC0180C2000023RemoteBread-writecurrentNID Series card Port 2 L2CP Mode 0180C2000023 0: Forward 1: Discard 2: Peer
1.3.6.1.4.1.4756.20.502.20.1.1718ColumnnidL2CPPort2DMAC0180C2000024RemoteBread-writecurrentNID Series card Port 2 L2CP Mode 0180C2000024 0: Forward 1: Discard 2: Peer
1.3.6.1.4.1.4756.20.502.20.1.1719ColumnnidL2CPPort2DMAC0180C2000025RemoteBread-writecurrentNID Series card Port 2 L2CP Mode 0180C2000025 0: Forward 1: Discard 2: Peer
1.3.6.1.4.1.4756.20.502.20.1.1720ColumnnidL2CPPort2DMAC0180C2000026RemoteBread-writecurrentNID Series card Port 2 L2CP Mode 0180C2000026 0: Forward 1: Discard 2: Peer
1.3.6.1.4.1.4756.20.502.20.1.1721ColumnnidL2CPPort2DMAC0180C2000027RemoteBread-writecurrentNID Series card Port 2 L2CP Mode 0180C2000027 0: Forward 1: Discard 2: Peer
1.3.6.1.4.1.4756.20.502.20.1.1722ColumnnidL2CPPort2DMAC0180C2000028RemoteBread-writecurrentNID Series card Port 2 L2CP Mode 0180C2000028 0: Forward 1: Discard 2: Peer
1.3.6.1.4.1.4756.20.502.20.1.1723ColumnnidL2CPPort2DMAC0180C2000029RemoteBread-writecurrentNID Series card Port 2 L2CP Mode 0180C2000029 0: Forward 1: Discard 2: Peer
1.3.6.1.4.1.4756.20.502.20.1.1724ColumnnidL2CPPort2DMAC0180C200002ARemoteBread-writecurrentNID Series card Port 2 L2CP Mode 0180C200002A 0: Forward 1: Discard 2: Peer
1.3.6.1.4.1.4756.20.502.20.1.1725ColumnnidL2CPPort2DMAC0180C200002BRemoteBread-writecurrentNID Series card Port 2 L2CP Mode 0180C200002B 0: Forward 1: Discard 2: Peer
1.3.6.1.4.1.4756.20.502.20.1.1726ColumnnidL2CPPort2DMAC0180C200002CRemoteBread-writecurrentNID Series card Port 2 L2CP Mode 0180C200002C 0: Forward 1: Discard 2: Peer
1.3.6.1.4.1.4756.20.502.20.1.1727ColumnnidL2CPPort2DMAC0180C200002DRemoteBread-writecurrentNID Series card Port 2 L2CP Mode 0180C200002D 0: Forward 1: Discard 2: Peer
1.3.6.1.4.1.4756.20.502.20.1.1728ColumnnidL2CPPort2DMAC0180C200002ERemoteBread-writecurrentNID Series card Port 2 L2CP Mode 0180C200002E 0: Forward 1: Discard 2: Peer
1.3.6.1.4.1.4756.20.502.20.1.1729ColumnnidL2CPPort2DMAC0180C200002FRemoteBread-writecurrentNID Series card Port 2 L2CP Mode 0180C200002F 0: Forward 1: Discard 1: Peer
1.3.6.1.4.1.4756.20.502.20.1.1730ColumnnidL2CPPort3DMAC0180C2000000RemoteBread-writecurrentNID Series card Port 3 L2CP Mode 0180C2000000 0: Forward 1: Discard 2: Peer
1.3.6.1.4.1.4756.20.502.20.1.1731ColumnnidL2CPPort3DMAC0180C2000001RemoteBread-writecurrentNID Series card Port 3 L2CP Mode 0180C2000001 0: Forward 1: Discard 2: Peer
1.3.6.1.4.1.4756.20.502.20.1.1732ColumnnidL2CPPort3DMAC0180C2000002RemoteBread-writecurrentNID Series card Port 3 L2CP Mode 0180C2000002 0: Forward 1: Discard 2: Peer
1.3.6.1.4.1.4756.20.502.20.1.1733ColumnnidL2CPPort3DMAC0180C2000003RemoteBread-writecurrentNID Series card Port 3 L2CP Mode 0180C2000003 0: Forward 1: Discard 2: Peer
1.3.6.1.4.1.4756.20.502.20.1.1734ColumnnidL2CPPort3DMAC0180C2000004RemoteBread-writecurrentNID Series card Port 3 L2CP Mode 0180C2000004 0: Forward 1: Discard 2: Peer
1.3.6.1.4.1.4756.20.502.20.1.1735ColumnnidL2CPPort3DMAC0180C2000005RemoteBread-writecurrentNID Series card Port 3 L2CP Mode 0180C2000005 0: Forward 1: Discard 2: Peer
1.3.6.1.4.1.4756.20.502.20.1.1736ColumnnidL2CPPort3DMAC0180C2000006RemoteBread-writecurrentNID Series card Port 3 L2CP Mode 0180C2000006 0: Forward 1: Discard 2: Peer
1.3.6.1.4.1.4756.20.502.20.1.1737ColumnnidL2CPPort3DMAC0180C2000007RemoteBread-writecurrentNID Series card Port 3 L2CP Mode 0180C2000007 0: Forward 1: Discard 2: Peer
1.3.6.1.4.1.4756.20.502.20.1.1738ColumnnidL2CPPort3DMAC0180C2000008RemoteBread-writecurrentNID Series card Port 3 L2CP Mode 0180C2000008 0: Forward 1: Discard 2: Peer
1.3.6.1.4.1.4756.20.502.20.1.1739ColumnnidL2CPPort3DMAC0180C2000009RemoteBread-writecurrentNID Series card Port 3 L2CP Mode 0180C2000009 0: Forward 1: Discard 2: Peer
1.3.6.1.4.1.4756.20.502.20.1.1740ColumnnidL2CPPort3DMAC0180C200000ARemoteBread-writecurrentNID Series card Port 3 L2CP Mode 0180C200000A 0: Forward 1: Discard 2: Peer
1.3.6.1.4.1.4756.20.502.20.1.1741ColumnnidL2CPPort3DMAC0180C200000BRemoteBread-writecurrentNID Series card Port 3 L2CP Mode 0180C200000B 0: Forward 1: Discard 2: Peer
1.3.6.1.4.1.4756.20.502.20.1.1742ColumnnidL2CPPort3DMAC0180C200000CRemoteBread-writecurrentNID Series card Port 3 L2CP Mode 0180C200000C 0: Forward 1: Discard 2: Peer
1.3.6.1.4.1.4756.20.502.20.1.1743ColumnnidL2CPPort3DMAC0180C200000DRemoteBread-writecurrentNID Series card Port 3 L2CP Mode 0180C200000D 0: Forward 1: Discard 2: Peer
1.3.6.1.4.1.4756.20.502.20.1.1744ColumnnidL2CPPort3DMAC0180C200000ERemoteBread-writecurrentNID Series card Port 3 L2CP Mode 0180C200000E 0: Forward 1: Discard 2: Peer
1.3.6.1.4.1.4756.20.502.20.1.1745ColumnnidL2CPPort3DMAC0180C200000FRemoteBread-writecurrentNID Series card Port 3 L2CP Mode 0180C200000F 0: Forward 1: Discard 2: Peer
1.3.6.1.4.1.4756.20.502.20.1.1746ColumnnidL2CPPort3DMAC0180C2000010RemoteBread-writecurrentNID Series card Port 3 L2CP Mode 0180C2000010 0: Forward 1: Discard 2: Peer
1.3.6.1.4.1.4756.20.502.20.1.1747ColumnnidL2CPPort3DMAC0180C2000020RemoteBread-writecurrentNID Series card Port 3 L2CP Mode 0180C2000020 0: Forward 1: Discard 2: Peer
1.3.6.1.4.1.4756.20.502.20.1.1748ColumnnidL2CPPort3DMAC0180C2000021RemoteBread-writecurrentNID Series card Port 3 L2CP Mode 0180C2000021 0: Forward 1: Discard 2: Peer
1.3.6.1.4.1.4756.20.502.20.1.1749ColumnnidL2CPPort3DMAC0180C2000022RemoteBread-writecurrentNID Series card Port 3 L2CP Mode 0180C2000022 0: Forward 1: Discard 2: Peer
1.3.6.1.4.1.4756.20.502.20.1.1750ColumnnidL2CPPort3DMAC0180C2000023RemoteBread-writecurrentNID Series card Port 3 L2CP Mode 0180C2000023 0: Forward 1: Discard 2: Peer
1.3.6.1.4.1.4756.20.502.20.1.1751ColumnnidL2CPPort3DMAC0180C2000024RemoteBread-writecurrentNID Series card Port 3 L2CP Mode 0180C2000024 0: Forward 1: Discard 2: Peer
1.3.6.1.4.1.4756.20.502.20.1.1752ColumnnidL2CPPort3DMAC0180C2000025RemoteBread-writecurrentNID Series card Port 3 L2CP Mode 0180C2000025 0: Forward 1: Discard 2: Peer
1.3.6.1.4.1.4756.20.502.20.1.1753ColumnnidL2CPPort3DMAC0180C2000026RemoteBread-writecurrentNID Series card Port 3 L2CP Mode 0180C2000026 0: Forward 1: Discard 2: Peer
1.3.6.1.4.1.4756.20.502.20.1.1754ColumnnidL2CPPort3DMAC0180C2000027RemoteBread-writecurrentNID Series card Port 3 L2CP Mode 0180C2000027 0: Forward 1: Discard 2: Peer
1.3.6.1.4.1.4756.20.502.20.1.1755ColumnnidL2CPPort3DMAC0180C2000028RemoteBread-writecurrentNID Series card Port 3 L2CP Mode 0180C2000028 0: Forward 1: Discard 2: Peer
1.3.6.1.4.1.4756.20.502.20.1.1756ColumnnidL2CPPort3DMAC0180C2000029RemoteBread-writecurrentNID Series card Port 3 L2CP Mode 0180C2000029 0: Forward 1: Discard 2: Peer
1.3.6.1.4.1.4756.20.502.20.1.1757ColumnnidL2CPPort3DMAC0180C200002ARemoteBread-writecurrentNID Series card Port 3 L2CP Mode 0180C200002A 0: Forward 1: Discard 2: Peer
1.3.6.1.4.1.4756.20.502.20.1.1758ColumnnidL2CPPort3DMAC0180C200002BRemoteBread-writecurrentNID Series card Port 3 L2CP Mode 0180C200002B 0: Forward 1: Discard 2: Peer
1.3.6.1.4.1.4756.20.502.20.1.1759ColumnnidL2CPPort3DMAC0180C200002CRemoteBread-writecurrentNID Series card Port 3 L2CP Mode 0180C200002C 0: Forward 1: Discard 2: Peer
1.3.6.1.4.1.4756.20.502.20.1.1760ColumnnidL2CPPort3DMAC0180C200002DRemoteBread-writecurrentNID Series card Port 3 L2CP Mode 0180C200002D 0: Forward 1: Discard 2: Peer
1.3.6.1.4.1.4756.20.502.20.1.1761ColumnnidL2CPPort3DMAC0180C200002ERemoteBread-writecurrentNID Series card Port 3 L2CP Mode 0180C200002E 0: Forward 1: Discard 2: Peer
1.3.6.1.4.1.4756.20.502.20.1.1762ColumnnidL2CPPort3DMAC0180C200002FRemoteBread-writecurrentNID Series card Port 3 L2CP Mode 0180C200002F 0: Forward 1: Discard 1: Peer
1.3.6.1.4.1.4756.20.502.20.1.1763ColumnnidL2CPPort4DMAC0180C2000000RemoteBread-writecurrentNID Series card Port 4 L2CP Mode 0180C2000000 0: Forward 1: Discard 2: Peer
1.3.6.1.4.1.4756.20.502.20.1.1764ColumnnidL2CPPort4DMAC0180C2000001RemoteBread-writecurrentNID Series card Port 4 L2CP Mode 0180C2000001 0: Forward 1: Discard 2: Peer
1.3.6.1.4.1.4756.20.502.20.1.1765ColumnnidL2CPPort4DMAC0180C2000002RemoteBread-writecurrentNID Series card Port 4 L2CP Mode 0180C2000002 0: Forward 1: Discard 2: Peer
1.3.6.1.4.1.4756.20.502.20.1.1766ColumnnidL2CPPort4DMAC0180C2000003RemoteBread-writecurrentNID Series card Port 4 L2CP Mode 0180C2000003 0: Forward 1: Discard 2: Peer
1.3.6.1.4.1.4756.20.502.20.1.1767ColumnnidL2CPPort4DMAC0180C2000004RemoteBread-writecurrentNID Series card Port 4 L2CP Mode 0180C2000004 0: Forward 1: Discard 2: Peer
1.3.6.1.4.1.4756.20.502.20.1.1768ColumnnidL2CPPort4DMAC0180C2000005RemoteBread-writecurrentNID Series card Port 4 L2CP Mode 0180C2000005 0: Forward 1: Discard 2: Peer
1.3.6.1.4.1.4756.20.502.20.1.1769ColumnnidL2CPPort4DMAC0180C2000006RemoteBread-writecurrentNID Series card Port 4 L2CP Mode 0180C2000006 0: Forward 1: Discard 2: Peer
1.3.6.1.4.1.4756.20.502.20.1.1770ColumnnidL2CPPort4DMAC0180C2000007RemoteBread-writecurrentNID Series card Port 4 L2CP Mode 0180C2000007 0: Forward 1: Discard 2: Peer
1.3.6.1.4.1.4756.20.502.20.1.1771ColumnnidL2CPPort4DMAC0180C2000008RemoteBread-writecurrentNID Series card Port 4 L2CP Mode 0180C2000008 0: Forward 1: Discard 2: Peer
1.3.6.1.4.1.4756.20.502.20.1.1772ColumnnidL2CPPort4DMAC0180C2000009RemoteBread-writecurrentNID Series card Port 4 L2CP Mode 0180C2000009 0: Forward 1: Discard 2: Peer
1.3.6.1.4.1.4756.20.502.20.1.1773ColumnnidL2CPPort4DMAC0180C200000ARemoteBread-writecurrentNID Series card Port 4 L2CP Mode 0180C200000A 0: Forward 1: Discard 2: Peer
1.3.6.1.4.1.4756.20.502.20.1.1774ColumnnidL2CPPort4DMAC0180C200000BRemoteBread-writecurrentNID Series card Port 4 L2CP Mode 0180C200000B 0: Forward 1: Discard 2: Peer
1.3.6.1.4.1.4756.20.502.20.1.1775ColumnnidL2CPPort4DMAC0180C200000CRemoteBread-writecurrentNID Series card Port 4 L2CP Mode 0180C200000C 0: Forward 1: Discard 2: Peer
1.3.6.1.4.1.4756.20.502.20.1.1776ColumnnidL2CPPort4DMAC0180C200000DRemoteBread-writecurrentNID Series card Port 4 L2CP Mode 0180C200000D 0: Forward 1: Discard 2: Peer
1.3.6.1.4.1.4756.20.502.20.1.1777ColumnnidL2CPPort4DMAC0180C200000ERemoteBread-writecurrentNID Series card Port 4 L2CP Mode 0180C200000E 0: Forward 1: Discard 2: Peer
1.3.6.1.4.1.4756.20.502.20.1.1778ColumnnidL2CPPort4DMAC0180C200000FRemoteBread-writecurrentNID Series card Port 4 L2CP Mode 0180C200000F 0: Forward 1: Discard 2: Peer
1.3.6.1.4.1.4756.20.502.20.1.1779ColumnnidL2CPPort4DMAC0180C2000010RemoteBread-writecurrentNID Series card Port 4 L2CP Mode 0180C2000010 0: Forward 1: Discard 2: Peer
1.3.6.1.4.1.4756.20.502.20.1.1780ColumnnidL2CPPort4DMAC0180C2000020RemoteBread-writecurrentNID Series card Port 4 L2CP Mode 0180C2000020 0: Forward 1: Discard 2: Peer
1.3.6.1.4.1.4756.20.502.20.1.1781ColumnnidL2CPPort4DMAC0180C2000021RemoteBread-writecurrentNID Series card Port 4 L2CP Mode 0180C2000021 0: Forward 1: Discard 2: Peer
1.3.6.1.4.1.4756.20.502.20.1.1782ColumnnidL2CPPort4DMAC0180C2000022RemoteBread-writecurrentNID Series card Port 4 L2CP Mode 0180C2000022 0: Forward 1: Discard 2: Peer
1.3.6.1.4.1.4756.20.502.20.1.1783ColumnnidL2CPPort4DMAC0180C2000023RemoteBread-writecurrentNID Series card Port 4 L2CP Mode 0180C2000023 0: Forward 1: Discard 2: Peer
1.3.6.1.4.1.4756.20.502.20.1.1784ColumnnidL2CPPort4DMAC0180C2000024RemoteBread-writecurrentNID Series card Port 4 L2CP Mode 0180C2000024 0: Forward 1: Discard 2: Peer
1.3.6.1.4.1.4756.20.502.20.1.1785ColumnnidL2CPPort4DMAC0180C2000025RemoteBread-writecurrentNID Series card Port 4 L2CP Mode 0180C2000025 0: Forward 1: Discard 2: Peer
1.3.6.1.4.1.4756.20.502.20.1.1786ColumnnidL2CPPort4DMAC0180C2000026RemoteBread-writecurrentNID Series card Port 4 L2CP Mode 0180C2000026 0: Forward 1: Discard 2: Peer
1.3.6.1.4.1.4756.20.502.20.1.1787ColumnnidL2CPPort4DMAC0180C2000027RemoteBread-writecurrentNID Series card Port 4 L2CP Mode 0180C2000027 0: Forward 1: Discard 2: Peer
1.3.6.1.4.1.4756.20.502.20.1.1788ColumnnidL2CPPort4DMAC0180C2000028RemoteBread-writecurrentNID Series card Port 4 L2CP Mode 0180C2000028 0: Forward 1: Discard 2: Peer
1.3.6.1.4.1.4756.20.502.20.1.1789ColumnnidL2CPPort4DMAC0180C2000029RemoteBread-writecurrentNID Series card Port 4 L2CP Mode 0180C2000029 0: Forward 1: Discard 2: Peer
1.3.6.1.4.1.4756.20.502.20.1.1790ColumnnidL2CPPort4DMAC0180C200002ARemoteBread-writecurrentNID Series card Port 4 L2CP Mode 0180C200002A 0: Forward 1: Discard 2: Peer
1.3.6.1.4.1.4756.20.502.20.1.1791ColumnnidL2CPPort4DMAC0180C200002BRemoteBread-writecurrentNID Series card Port 4 L2CP Mode 0180C200002B 0: Forward 1: Discard 2: Peer
1.3.6.1.4.1.4756.20.502.20.1.1792ColumnnidL2CPPort4DMAC0180C200002CRemoteBread-writecurrentNID Series card Port 4 L2CP Mode 0180C200002C 0: Forward 1: Discard 2: Peer
1.3.6.1.4.1.4756.20.502.20.1.1793ColumnnidL2CPPort4DMAC0180C200002DRemoteBread-writecurrentNID Series card Port 4 L2CP Mode 0180C200002D 0: Forward 1: Discard 2: Peer
1.3.6.1.4.1.4756.20.502.20.1.1794ColumnnidL2CPPort4DMAC0180C200002ERemoteBread-writecurrentNID Series card Port 4 L2CP Mode 0180C200002E 0: Forward 1: Discard 2: Peer
1.3.6.1.4.1.4756.20.502.20.1.1795ColumnnidL2CPPort4DMAC0180C200002FRemoteBread-writecurrentNID Series card Port 4 L2CP Mode 0180C200002F 0: Forward 1: Discard 1: Peer
1.3.6.1.4.1.4756.20.502.20.1.1796ColumnnidL2CPPort5DMAC0180C2000000RemoteBread-writecurrentNID Series card Port 5 L2CP Mode 0180C2000000 0: Forward 1: Discard 2: Peer
1.3.6.1.4.1.4756.20.502.20.1.1797ColumnnidL2CPPort5DMAC0180C2000001RemoteBread-writecurrentNID Series card Port 5 L2CP Mode 0180C2000001 0: Forward 1: Discard 2: Peer
1.3.6.1.4.1.4756.20.502.20.1.1798ColumnnidL2CPPort5DMAC0180C2000002RemoteBread-writecurrentNID Series card Port 5 L2CP Mode 0180C2000002 0: Forward 1: Discard 2: Peer
1.3.6.1.4.1.4756.20.502.20.1.1799ColumnnidL2CPPort5DMAC0180C2000003RemoteBread-writecurrentNID Series card Port 5 L2CP Mode 0180C2000003 0: Forward 1: Discard 2: Peer
1.3.6.1.4.1.4756.20.502.20.1.1800ColumnnidL2CPPort5DMAC0180C2000004RemoteBread-writecurrentNID Series card Port 5 L2CP Mode 0180C2000004 0: Forward 1: Discard 2: Peer
1.3.6.1.4.1.4756.20.502.20.1.1801ColumnnidL2CPPort5DMAC0180C2000005RemoteBread-writecurrentNID Series card Port 5 L2CP Mode 0180C2000005 0: Forward 1: Discard 2: Peer
1.3.6.1.4.1.4756.20.502.20.1.1802ColumnnidL2CPPort5DMAC0180C2000006RemoteBread-writecurrentNID Series card Port 5 L2CP Mode 0180C2000006 0: Forward 1: Discard 2: Peer
1.3.6.1.4.1.4756.20.502.20.1.1803ColumnnidL2CPPort5DMAC0180C2000007RemoteBread-writecurrentNID Series card Port 5 L2CP Mode 0180C2000007 0: Forward 1: Discard 2: Peer
1.3.6.1.4.1.4756.20.502.20.1.1804ColumnnidL2CPPort5DMAC0180C2000008RemoteBread-writecurrentNID Series card Port 5 L2CP Mode 0180C2000008 0: Forward 1: Discard 2: Peer
1.3.6.1.4.1.4756.20.502.20.1.1805ColumnnidL2CPPort5DMAC0180C2000009RemoteBread-writecurrentNID Series card Port 5 L2CP Mode 0180C2000009 0: Forward 1: Discard 2: Peer
1.3.6.1.4.1.4756.20.502.20.1.1806ColumnnidL2CPPort5DMAC0180C200000ARemoteBread-writecurrentNID Series card Port 5 L2CP Mode 0180C200000A 0: Forward 1: Discard 2: Peer
1.3.6.1.4.1.4756.20.502.20.1.1807ColumnnidL2CPPort5DMAC0180C200000BRemoteBread-writecurrentNID Series card Port 5 L2CP Mode 0180C200000B 0: Forward 1: Discard 2: Peer
1.3.6.1.4.1.4756.20.502.20.1.1808ColumnnidL2CPPort5DMAC0180C200000CRemoteBread-writecurrentNID Series card Port 5 L2CP Mode 0180C200000C 0: Forward 1: Discard 2: Peer
1.3.6.1.4.1.4756.20.502.20.1.1809ColumnnidL2CPPort5DMAC0180C200000DRemoteBread-writecurrentNID Series card Port 5 L2CP Mode 0180C200000D 0: Forward 1: Discard 2: Peer
1.3.6.1.4.1.4756.20.502.20.1.1810ColumnnidL2CPPort5DMAC0180C200000ERemoteBread-writecurrentNID Series card Port 5 L2CP Mode 0180C200000E 0: Forward 1: Discard 2: Peer
1.3.6.1.4.1.4756.20.502.20.1.1811ColumnnidL2CPPort5DMAC0180C200000FRemoteBread-writecurrentNID Series card Port 5 L2CP Mode 0180C200000F 0: Forward 1: Discard 2: Peer
1.3.6.1.4.1.4756.20.502.20.1.1812ColumnnidL2CPPort5DMAC0180C2000010RemoteBread-writecurrentNID Series card Port 5 L2CP Mode 0180C2000010 0: Forward 1: Discard 2: Peer
1.3.6.1.4.1.4756.20.502.20.1.1813ColumnnidL2CPPort5DMAC0180C2000020RemoteBread-writecurrentNID Series card Port 5 L2CP Mode 0180C2000020 0: Forward 1: Discard 2: Peer
1.3.6.1.4.1.4756.20.502.20.1.1814ColumnnidL2CPPort5DMAC0180C2000021RemoteBread-writecurrentNID Series card Port 5 L2CP Mode 0180C2000021 0: Forward 1: Discard 2: Peer
1.3.6.1.4.1.4756.20.502.20.1.1815ColumnnidL2CPPort5DMAC0180C2000022RemoteBread-writecurrentNID Series card Port 5 L2CP Mode 0180C2000022 0: Forward 1: Discard 2: Peer
1.3.6.1.4.1.4756.20.502.20.1.1816ColumnnidL2CPPort5DMAC0180C2000023RemoteBread-writecurrentNID Series card Port 5 L2CP Mode 0180C2000023 0: Forward 1: Discard 2: Peer
1.3.6.1.4.1.4756.20.502.20.1.1817ColumnnidL2CPPort5DMAC0180C2000024RemoteBread-writecurrentNID Series card Port 5 L2CP Mode 0180C2000024 0: Forward 1: Discard 2: Peer
1.3.6.1.4.1.4756.20.502.20.1.1818ColumnnidL2CPPort5DMAC0180C2000025RemoteBread-writecurrentNID Series card Port 5 L2CP Mode 0180C2000025 0: Forward 1: Discard 2: Peer
1.3.6.1.4.1.4756.20.502.20.1.1819ColumnnidL2CPPort5DMAC0180C2000026RemoteBread-writecurrentNID Series card Port 5 L2CP Mode 0180C2000026 0: Forward 1: Discard 2: Peer
1.3.6.1.4.1.4756.20.502.20.1.1820ColumnnidL2CPPort5DMAC0180C2000027RemoteBread-writecurrentNID Series card Port 5 L2CP Mode 0180C2000027 0: Forward 1: Discard 2: Peer
1.3.6.1.4.1.4756.20.502.20.1.1821ColumnnidL2CPPort5DMAC0180C2000028RemoteBread-writecurrentNID Series card Port 5 L2CP Mode 0180C2000028 0: Forward 1: Discard 2: Peer
1.3.6.1.4.1.4756.20.502.20.1.1822ColumnnidL2CPPort5DMAC0180C2000029RemoteBread-writecurrentNID Series card Port 5 L2CP Mode 0180C2000029 0: Forward 1: Discard 2: Peer
1.3.6.1.4.1.4756.20.502.20.1.1823ColumnnidL2CPPort5DMAC0180C200002ARemoteBread-writecurrentNID Series card Port 5 L2CP Mode 0180C200002A 0: Forward 1: Discard 2: Peer
1.3.6.1.4.1.4756.20.502.20.1.1824ColumnnidL2CPPort5DMAC0180C200002BRemoteBread-writecurrentNID Series card Port 5 L2CP Mode 0180C200002B 0: Forward 1: Discard 2: Peer
1.3.6.1.4.1.4756.20.502.20.1.1825ColumnnidL2CPPort5DMAC0180C200002CRemoteBread-writecurrentNID Series card Port 5 L2CP Mode 0180C200002C 0: Forward 1: Discard 2: Peer
1.3.6.1.4.1.4756.20.502.20.1.1826ColumnnidL2CPPort5DMAC0180C200002DRemoteBread-writecurrentNID Series card Port 5 L2CP Mode 0180C200002D 0: Forward 1: Discard 2: Peer
1.3.6.1.4.1.4756.20.502.20.1.1827ColumnnidL2CPPort5DMAC0180C200002ERemoteBread-writecurrentNID Series card Port 5 L2CP Mode 0180C200002E 0: Forward 1: Discard 2: Peer
1.3.6.1.4.1.4756.20.502.20.1.1828ColumnnidL2CPPort5DMAC0180C200002FRemoteBread-writecurrentNID Series card Port 5 L2CP Mode 0180C200002F 0: Forward 1: Discard 1: Peer
1.3.6.1.4.1.4756.20.502.20.1.1829ColumnnidL2CPPort6DMAC0180C2000000RemoteBread-writecurrentNID Series card Port 6 L2CP Mode 0180C2000000 0: Forward 1: Discard 2: Peer
1.3.6.1.4.1.4756.20.502.20.1.1830ColumnnidL2CPPort6DMAC0180C2000001RemoteBread-writecurrentNID Series card Port 6 L2CP Mode 0180C2000001 0: Forward 1: Discard 2: Peer
1.3.6.1.4.1.4756.20.502.20.1.1831ColumnnidL2CPPort6DMAC0180C2000002RemoteBread-writecurrentNID Series card Port 6 L2CP Mode 0180C2000002 0: Forward 1: Discard 2: Peer
1.3.6.1.4.1.4756.20.502.20.1.1832ColumnnidL2CPPort6DMAC0180C2000003RemoteBread-writecurrentNID Series card Port 6 L2CP Mode 0180C2000003 0: Forward 1: Discard 2: Peer
1.3.6.1.4.1.4756.20.502.20.1.1833ColumnnidL2CPPort6DMAC0180C2000004RemoteBread-writecurrentNID Series card Port 6 L2CP Mode 0180C2000004 0: Forward 1: Discard 2: Peer
1.3.6.1.4.1.4756.20.502.20.1.1834ColumnnidL2CPPort6DMAC0180C2000005RemoteBread-writecurrentNID Series card Port 6 L2CP Mode 0180C2000005 0: Forward 1: Discard 2: Peer
1.3.6.1.4.1.4756.20.502.20.1.1835ColumnnidL2CPPort6DMAC0180C2000006RemoteBread-writecurrentNID Series card Port 6 L2CP Mode 0180C2000006 0: Forward 1: Discard 2: Peer
1.3.6.1.4.1.4756.20.502.20.1.1836ColumnnidL2CPPort6DMAC0180C2000007RemoteBread-writecurrentNID Series card Port 6 L2CP Mode 0180C2000007 0: Forward 1: Discard 2: Peer
1.3.6.1.4.1.4756.20.502.20.1.1837ColumnnidL2CPPort6DMAC0180C2000008RemoteBread-writecurrentNID Series card Port 6 L2CP Mode 0180C2000008 0: Forward 1: Discard 2: Peer
1.3.6.1.4.1.4756.20.502.20.1.1838ColumnnidL2CPPort6DMAC0180C2000009RemoteBread-writecurrentNID Series card Port 6 L2CP Mode 0180C2000009 0: Forward 1: Discard 2: Peer
1.3.6.1.4.1.4756.20.502.20.1.1839ColumnnidL2CPPort6DMAC0180C200000ARemoteBread-writecurrentNID Series card Port 6 L2CP Mode 0180C200000A 0: Forward 1: Discard 2: Peer
1.3.6.1.4.1.4756.20.502.20.1.1840ColumnnidL2CPPort6DMAC0180C200000BRemoteBread-writecurrentNID Series card Port 6 L2CP Mode 0180C200000B 0: Forward 1: Discard 2: Peer
1.3.6.1.4.1.4756.20.502.20.1.1841ColumnnidL2CPPort6DMAC0180C200000CRemoteBread-writecurrentNID Series card Port 6 L2CP Mode 0180C200000C 0: Forward 1: Discard 2: Peer
1.3.6.1.4.1.4756.20.502.20.1.1842ColumnnidL2CPPort6DMAC0180C200000DRemoteBread-writecurrentNID Series card Port 6 L2CP Mode 0180C200000D 0: Forward 1: Discard 2: Peer
1.3.6.1.4.1.4756.20.502.20.1.1843ColumnnidL2CPPort6DMAC0180C200000ERemoteBread-writecurrentNID Series card Port 6 L2CP Mode 0180C200000E 0: Forward 1: Discard 2: Peer
1.3.6.1.4.1.4756.20.502.20.1.1844ColumnnidL2CPPort6DMAC0180C200000FRemoteBread-writecurrentNID Series card Port 6 L2CP Mode 0180C200000F 0: Forward 1: Discard 2: Peer
1.3.6.1.4.1.4756.20.502.20.1.1845ColumnnidL2CPPort6DMAC0180C2000010RemoteBread-writecurrentNID Series card Port 6 L2CP Mode 0180C2000010 0: Forward 1: Discard 2: Peer
1.3.6.1.4.1.4756.20.502.20.1.1846ColumnnidL2CPPort6DMAC0180C2000020RemoteBread-writecurrentNID Series card Port 6 L2CP Mode 0180C2000020 0: Forward 1: Discard 2: Peer
1.3.6.1.4.1.4756.20.502.20.1.1847ColumnnidL2CPPort6DMAC0180C2000021RemoteBread-writecurrentNID Series card Port 6 L2CP Mode 0180C2000021 0: Forward 1: Discard 2: Peer
1.3.6.1.4.1.4756.20.502.20.1.1848ColumnnidL2CPPort6DMAC0180C2000022RemoteBread-writecurrentNID Series card Port 6 L2CP Mode 0180C2000022 0: Forward 1: Discard 2: Peer
1.3.6.1.4.1.4756.20.502.20.1.1849ColumnnidL2CPPort6DMAC0180C2000023RemoteBread-writecurrentNID Series card Port 6 L2CP Mode 0180C2000023 0: Forward 1: Discard 2: Peer
1.3.6.1.4.1.4756.20.502.20.1.1850ColumnnidL2CPPort6DMAC0180C2000024RemoteBread-writecurrentNID Series card Port 6 L2CP Mode 0180C2000024 0: Forward 1: Discard 2: Peer
1.3.6.1.4.1.4756.20.502.20.1.1851ColumnnidL2CPPort6DMAC0180C2000025RemoteBread-writecurrentNID Series card Port 6 L2CP Mode 0180C2000025 0: Forward 1: Discard 2: Peer
1.3.6.1.4.1.4756.20.502.20.1.1852ColumnnidL2CPPort6DMAC0180C2000026RemoteBread-writecurrentNID Series card Port 6 L2CP Mode 0180C2000026 0: Forward 1: Discard 2: Peer
1.3.6.1.4.1.4756.20.502.20.1.1853ColumnnidL2CPPort6DMAC0180C2000027RemoteBread-writecurrentNID Series card Port 6 L2CP Mode 0180C2000027 0: Forward 1: Discard 2: Peer
1.3.6.1.4.1.4756.20.502.20.1.1854ColumnnidL2CPPort6DMAC0180C2000028RemoteBread-writecurrentNID Series card Port 6 L2CP Mode 0180C2000028 0: Forward 1: Discard 2: Peer
1.3.6.1.4.1.4756.20.502.20.1.1855ColumnnidL2CPPort6DMAC0180C2000029RemoteBread-writecurrentNID Series card Port 6 L2CP Mode 0180C2000029 0: Forward 1: Discard 2: Peer
1.3.6.1.4.1.4756.20.502.20.1.1856ColumnnidL2CPPort6DMAC0180C200002ARemoteBread-writecurrentNID Series card Port 6 L2CP Mode 0180C200002A 0: Forward 1: Discard 2: Peer
1.3.6.1.4.1.4756.20.502.20.1.1857ColumnnidL2CPPort6DMAC0180C200002BRemoteBread-writecurrentNID Series card Port 6 L2CP Mode 0180C200002B 0: Forward 1: Discard 2: Peer
1.3.6.1.4.1.4756.20.502.20.1.1858ColumnnidL2CPPort6DMAC0180C200002CRemoteBread-writecurrentNID Series card Port 6 L2CP Mode 0180C200002C 0: Forward 1: Discard 2: Peer
1.3.6.1.4.1.4756.20.502.20.1.1859ColumnnidL2CPPort6DMAC0180C200002DRemoteBread-writecurrentNID Series card Port 6 L2CP Mode 0180C200002D 0: Forward 1: Discard 2: Peer
1.3.6.1.4.1.4756.20.502.20.1.1860ColumnnidL2CPPort6DMAC0180C200002ERemoteBread-writecurrentNID Series card Port 6 L2CP Mode 0180C200002E 0: Forward 1: Discard 2: Peer
1.3.6.1.4.1.4756.20.502.20.1.1861ColumnnidL2CPPort6DMAC0180C200002FRemoteBread-writecurrentNID Series card Port 6 L2CP Mode 0180C200002F 0: Forward 1: Discard 1: Peer
1.3.6.1.4.1.4756.20.502.20.1.1862ColumnnidL2CPPort7DMAC0180C2000000RemoteBread-writecurrentNID Series card Port 7 L2CP Mode 0180C2000000 0: Forward 1: Discard 2: Peer
1.3.6.1.4.1.4756.20.502.20.1.1863ColumnnidL2CPPort7DMAC0180C2000001RemoteBread-writecurrentNID Series card Port 7 L2CP Mode 0180C2000001 0: Forward 1: Discard 2: Peer
1.3.6.1.4.1.4756.20.502.20.1.1864ColumnnidL2CPPort7DMAC0180C2000002RemoteBread-writecurrentNID Series card Port 7 L2CP Mode 0180C2000002 0: Forward 1: Discard 2: Peer
1.3.6.1.4.1.4756.20.502.20.1.1865ColumnnidL2CPPort7DMAC0180C2000003RemoteBread-writecurrentNID Series card Port 7 L2CP Mode 0180C2000003 0: Forward 1: Discard 2: Peer
1.3.6.1.4.1.4756.20.502.20.1.1866ColumnnidL2CPPort7DMAC0180C2000004RemoteBread-writecurrentNID Series card Port 7 L2CP Mode 0180C2000004 0: Forward 1: Discard 2: Peer
1.3.6.1.4.1.4756.20.502.20.1.1867ColumnnidL2CPPort7DMAC0180C2000005RemoteBread-writecurrentNID Series card Port 7 L2CP Mode 0180C2000005 0: Forward 1: Discard 2: Peer
1.3.6.1.4.1.4756.20.502.20.1.1868ColumnnidL2CPPort7DMAC0180C2000006RemoteBread-writecurrentNID Series card Port 7 L2CP Mode 0180C2000006 0: Forward 1: Discard 2: Peer
1.3.6.1.4.1.4756.20.502.20.1.1869ColumnnidL2CPPort7DMAC0180C2000007RemoteBread-writecurrentNID Series card Port 7 L2CP Mode 0180C2000007 0: Forward 1: Discard 2: Peer
1.3.6.1.4.1.4756.20.502.20.1.1870ColumnnidL2CPPort7DMAC0180C2000008RemoteBread-writecurrentNID Series card Port 7 L2CP Mode 0180C2000008 0: Forward 1: Discard 2: Peer
1.3.6.1.4.1.4756.20.502.20.1.1871ColumnnidL2CPPort7DMAC0180C2000009RemoteBread-writecurrentNID Series card Port 7 L2CP Mode 0180C2000009 0: Forward 1: Discard 2: Peer
1.3.6.1.4.1.4756.20.502.20.1.1872ColumnnidL2CPPort7DMAC0180C200000ARemoteBread-writecurrentNID Series card Port 7 L2CP Mode 0180C200000A 0: Forward 1: Discard 2: Peer
1.3.6.1.4.1.4756.20.502.20.1.1873ColumnnidL2CPPort7DMAC0180C200000BRemoteBread-writecurrentNID Series card Port 7 L2CP Mode 0180C200000B 0: Forward 1: Discard 2: Peer
1.3.6.1.4.1.4756.20.502.20.1.1874ColumnnidL2CPPort7DMAC0180C200000CRemoteBread-writecurrentNID Series card Port 7 L2CP Mode 0180C200000C 0: Forward 1: Discard 2: Peer
1.3.6.1.4.1.4756.20.502.20.1.1875ColumnnidL2CPPort7DMAC0180C200000DRemoteBread-writecurrentNID Series card Port 7 L2CP Mode 0180C200000D 0: Forward 1: Discard 2: Peer
1.3.6.1.4.1.4756.20.502.20.1.1876ColumnnidL2CPPort7DMAC0180C200000ERemoteBread-writecurrentNID Series card Port 7 L2CP Mode 0180C200000E 0: Forward 1: Discard 2: Peer
1.3.6.1.4.1.4756.20.502.20.1.1877ColumnnidL2CPPort7DMAC0180C200000FRemoteBread-writecurrentNID Series card Port 7 L2CP Mode 0180C200000F 0: Forward 1: Discard 2: Peer
1.3.6.1.4.1.4756.20.502.20.1.1878ColumnnidL2CPPort7DMAC0180C2000010RemoteBread-writecurrentNID Series card Port 7 L2CP Mode 0180C2000010 0: Forward 1: Discard 2: Peer
1.3.6.1.4.1.4756.20.502.20.1.1879ColumnnidL2CPPort7DMAC0180C2000020RemoteBread-writecurrentNID Series card Port 7 L2CP Mode 0180C2000020 0: Forward 1: Discard 2: Peer
1.3.6.1.4.1.4756.20.502.20.1.1880ColumnnidL2CPPort7DMAC0180C2000021RemoteBread-writecurrentNID Series card Port 7 L2CP Mode 0180C2000021 0: Forward 1: Discard 2: Peer
1.3.6.1.4.1.4756.20.502.20.1.1881ColumnnidL2CPPort7DMAC0180C2000022RemoteBread-writecurrentNID Series card Port 7 L2CP Mode 0180C2000022 0: Forward 1: Discard 2: Peer
1.3.6.1.4.1.4756.20.502.20.1.1882ColumnnidL2CPPort7DMAC0180C2000023RemoteBread-writecurrentNID Series card Port 7 L2CP Mode 0180C2000023 0: Forward 1: Discard 2: Peer
1.3.6.1.4.1.4756.20.502.20.1.1883ColumnnidL2CPPort7DMAC0180C2000024RemoteBread-writecurrentNID Series card Port 7 L2CP Mode 0180C2000024 0: Forward 1: Discard 2: Peer
1.3.6.1.4.1.4756.20.502.20.1.1884ColumnnidL2CPPort7DMAC0180C2000025RemoteBread-writecurrentNID Series card Port 7 L2CP Mode 0180C2000025 0: Forward 1: Discard 2: Peer
1.3.6.1.4.1.4756.20.502.20.1.1885ColumnnidL2CPPort7DMAC0180C2000026RemoteBread-writecurrentNID Series card Port 7 L2CP Mode 0180C2000026 0: Forward 1: Discard 2: Peer
1.3.6.1.4.1.4756.20.502.20.1.1886ColumnnidL2CPPort7DMAC0180C2000027RemoteBread-writecurrentNID Series card Port 7 L2CP Mode 0180C2000027 0: Forward 1: Discard 2: Peer
1.3.6.1.4.1.4756.20.502.20.1.1887ColumnnidL2CPPort7DMAC0180C2000028RemoteBread-writecurrentNID Series card Port 7 L2CP Mode 0180C2000028 0: Forward 1: Discard 2: Peer
1.3.6.1.4.1.4756.20.502.20.1.1888ColumnnidL2CPPort7DMAC0180C2000029RemoteBread-writecurrentNID Series card Port 7 L2CP Mode 0180C2000029 0: Forward 1: Discard 2: Peer
1.3.6.1.4.1.4756.20.502.20.1.1889ColumnnidL2CPPort7DMAC0180C200002ARemoteBread-writecurrentNID Series card Port 7 L2CP Mode 0180C200002A 0: Forward 1: Discard 2: Peer
1.3.6.1.4.1.4756.20.502.20.1.1890ColumnnidL2CPPort7DMAC0180C200002BRemoteBread-writecurrentNID Series card Port 7 L2CP Mode 0180C200002B 0: Forward 1: Discard 2: Peer
1.3.6.1.4.1.4756.20.502.20.1.1891ColumnnidL2CPPort7DMAC0180C200002CRemoteBread-writecurrentNID Series card Port 7 L2CP Mode 0180C200002C 0: Forward 1: Discard 2: Peer
1.3.6.1.4.1.4756.20.502.20.1.1892ColumnnidL2CPPort7DMAC0180C200002DRemoteBread-writecurrentNID Series card Port 7 L2CP Mode 0180C200002D 0: Forward 1: Discard 2: Peer
1.3.6.1.4.1.4756.20.502.20.1.1893ColumnnidL2CPPort7DMAC0180C200002ERemoteBread-writecurrentNID Series card Port 7 L2CP Mode 0180C200002E 0: Forward 1: Discard 2: Peer
1.3.6.1.4.1.4756.20.502.20.1.1894ColumnnidL2CPPort7DMAC0180C200002FRemoteBread-writecurrentNID Series card Port 7 L2CP Mode 0180C200002F 0: Forward 1: Discard 1: Peer
1.3.6.1.4.1.4756.20.502.20.1.1895ColumnnidL2CPPort8DMAC0180C2000000RemoteBread-writecurrentNID Series card Port 8 L2CP Mode 0180C2000000 0: Forward 1: Discard 2: Peer
1.3.6.1.4.1.4756.20.502.20.1.1896ColumnnidL2CPPort8DMAC0180C2000001RemoteBread-writecurrentNID Series card Port 8 L2CP Mode 0180C2000001 0: Forward 1: Discard 2: Peer
1.3.6.1.4.1.4756.20.502.20.1.1897ColumnnidL2CPPort8DMAC0180C2000002RemoteBread-writecurrentNID Series card Port 8 L2CP Mode 0180C2000002 0: Forward 1: Discard 2: Peer
1.3.6.1.4.1.4756.20.502.20.1.1898ColumnnidL2CPPort8DMAC0180C2000003RemoteBread-writecurrentNID Series card Port 8 L2CP Mode 0180C2000003 0: Forward 1: Discard 2: Peer
1.3.6.1.4.1.4756.20.502.20.1.1899ColumnnidL2CPPort8DMAC0180C2000004RemoteBread-writecurrentNID Series card Port 8 L2CP Mode 0180C2000004 0: Forward 1: Discard 2: Peer
1.3.6.1.4.1.4756.20.502.20.1.1900ColumnnidL2CPPort8DMAC0180C2000005RemoteBread-writecurrentNID Series card Port 8 L2CP Mode 0180C2000005 0: Forward 1: Discard 2: Peer
1.3.6.1.4.1.4756.20.502.20.1.1901ColumnnidL2CPPort8DMAC0180C2000006RemoteBread-writecurrentNID Series card Port 8 L2CP Mode 0180C2000006 0: Forward 1: Discard 2: Peer
1.3.6.1.4.1.4756.20.502.20.1.1902ColumnnidL2CPPort8DMAC0180C2000007RemoteBread-writecurrentNID Series card Port 8 L2CP Mode 0180C2000007 0: Forward 1: Discard 2: Peer
1.3.6.1.4.1.4756.20.502.20.1.1903ColumnnidL2CPPort8DMAC0180C2000008RemoteBread-writecurrentNID Series card Port 8 L2CP Mode 0180C2000008 0: Forward 1: Discard 2: Peer
1.3.6.1.4.1.4756.20.502.20.1.1904ColumnnidL2CPPort8DMAC0180C2000009RemoteBread-writecurrentNID Series card Port 8 L2CP Mode 0180C2000009 0: Forward 1: Discard 2: Peer
1.3.6.1.4.1.4756.20.502.20.1.1905ColumnnidL2CPPort8DMAC0180C200000ARemoteBread-writecurrentNID Series card Port 8 L2CP Mode 0180C200000A 0: Forward 1: Discard 2: Peer
1.3.6.1.4.1.4756.20.502.20.1.1906ColumnnidL2CPPort8DMAC0180C200000BRemoteBread-writecurrentNID Series card Port 8 L2CP Mode 0180C200000B 0: Forward 1: Discard 2: Peer
1.3.6.1.4.1.4756.20.502.20.1.1907ColumnnidL2CPPort8DMAC0180C200000CRemoteBread-writecurrentNID Series card Port 8 L2CP Mode 0180C200000C 0: Forward 1: Discard 2: Peer
1.3.6.1.4.1.4756.20.502.20.1.1908ColumnnidL2CPPort8DMAC0180C200000DRemoteBread-writecurrentNID Series card Port 8 L2CP Mode 0180C200000D 0: Forward 1: Discard 2: Peer
1.3.6.1.4.1.4756.20.502.20.1.1909ColumnnidL2CPPort8DMAC0180C200000ERemoteBread-writecurrentNID Series card Port 8 L2CP Mode 0180C200000E 0: Forward 1: Discard 2: Peer
1.3.6.1.4.1.4756.20.502.20.1.1910ColumnnidL2CPPort8DMAC0180C200000FRemoteBread-writecurrentNID Series card Port 8 L2CP Mode 0180C200000F 0: Forward 1: Discard 2: Peer
1.3.6.1.4.1.4756.20.502.20.1.1911ColumnnidL2CPPort8DMAC0180C2000010RemoteBread-writecurrentNID Series card Port 8 L2CP Mode 0180C2000010 0: Forward 1: Discard 2: Peer
1.3.6.1.4.1.4756.20.502.20.1.1912ColumnnidL2CPPort8DMAC0180C2000020RemoteBread-writecurrentNID Series card Port 8 L2CP Mode 0180C2000020 0: Forward 1: Discard 2: Peer
1.3.6.1.4.1.4756.20.502.20.1.1913ColumnnidL2CPPort8DMAC0180C2000021RemoteBread-writecurrentNID Series card Port 8 L2CP Mode 0180C2000021 0: Forward 1: Discard 2: Peer
1.3.6.1.4.1.4756.20.502.20.1.1914ColumnnidL2CPPort8DMAC0180C2000022RemoteBread-writecurrentNID Series card Port 8 L2CP Mode 0180C2000022 0: Forward 1: Discard 2: Peer
1.3.6.1.4.1.4756.20.502.20.1.1915ColumnnidL2CPPort8DMAC0180C2000023RemoteBread-writecurrentNID Series card Port 8 L2CP Mode 0180C2000023 0: Forward 1: Discard 2: Peer
1.3.6.1.4.1.4756.20.502.20.1.1916ColumnnidL2CPPort8DMAC0180C2000024RemoteBread-writecurrentNID Series card Port 8 L2CP Mode 0180C2000024 0: Forward 1: Discard 2: Peer
1.3.6.1.4.1.4756.20.502.20.1.1917ColumnnidL2CPPort8DMAC0180C2000025RemoteBread-writecurrentNID Series card Port 8 L2CP Mode 0180C2000025 0: Forward 1: Discard 2: Peer
1.3.6.1.4.1.4756.20.502.20.1.1918ColumnnidL2CPPort8DMAC0180C2000026RemoteBread-writecurrentNID Series card Port 8 L2CP Mode 0180C2000026 0: Forward 1: Discard 2: Peer
1.3.6.1.4.1.4756.20.502.20.1.1919ColumnnidL2CPPort8DMAC0180C2000027RemoteBread-writecurrentNID Series card Port 8 L2CP Mode 0180C2000027 0: Forward 1: Discard 2: Peer
1.3.6.1.4.1.4756.20.502.20.1.1920ColumnnidL2CPPort8DMAC0180C2000028RemoteBread-writecurrentNID Series card Port 8 L2CP Mode 0180C2000028 0: Forward 1: Discard 2: Peer
1.3.6.1.4.1.4756.20.502.20.1.1921ColumnnidL2CPPort8DMAC0180C2000029RemoteBread-writecurrentNID Series card Port 8 L2CP Mode 0180C2000029 0: Forward 1: Discard 2: Peer
1.3.6.1.4.1.4756.20.502.20.1.1922ColumnnidL2CPPort8DMAC0180C200002ARemoteBread-writecurrentNID Series card Port 8 L2CP Mode 0180C200002A 0: Forward 1: Discard 2: Peer
1.3.6.1.4.1.4756.20.502.20.1.1923ColumnnidL2CPPort8DMAC0180C200002BRemoteBread-writecurrentNID Series card Port 8 L2CP Mode 0180C200002B 0: Forward 1: Discard 2: Peer
1.3.6.1.4.1.4756.20.502.20.1.1924ColumnnidL2CPPort8DMAC0180C200002CRemoteBread-writecurrentNID Series card Port 8 L2CP Mode 0180C200002C 0: Forward 1: Discard 2: Peer
1.3.6.1.4.1.4756.20.502.20.1.1925ColumnnidL2CPPort8DMAC0180C200002DRemoteBread-writecurrentNID Series card Port 8 L2CP Mode 0180C200002D 0: Forward 1: Discard 2: Peer
1.3.6.1.4.1.4756.20.502.20.1.1926ColumnnidL2CPPort8DMAC0180C200002ERemoteBread-writecurrentNID Series card Port 8 L2CP Mode 0180C200002E 0: Forward 1: Discard 2: Peer
1.3.6.1.4.1.4756.20.502.20.1.1927ColumnnidL2CPPort8DMAC0180C200002FRemoteBread-writecurrentNID Series card Port 8 L2CP Mode 0180C200002F 0: Forward 1: Discard 1: Peer
1.3.6.1.4.1.4756.20.502.20.1.1928ColumnnidFx1DDRemoteBread-onlycurrentNID Series card fiber port Digital Diagnostic function: 0:No 1:Yes
1.3.6.1.4.1.4756.20.502.20.1.1929ColumnnidFx1DDVendorRemoteBread-onlycurrentNID Series card fiber port D/D information: Vendor name
1.3.6.1.4.1.4756.20.502.20.1.1930ColumnnidFx1DDPartNoRemoteBread-onlycurrentNID Series card fiber port D/D information: Vendor part number
1.3.6.1.4.1.4756.20.502.20.1.1931ColumnnidFx1DDFiberTypeRemoteBread-onlycurrentNID Series card fiber port D/D information: Fiber Type
1.3.6.1.4.1.4756.20.502.20.1.1932ColumnnidFx1DDWaveLenRemoteBread-onlycurrentNID Series card fiber port D/D information: Wave length
1.3.6.1.4.1.4756.20.502.20.1.1933ColumnnidFx1DDWaveLen2RemoteBread-onlycurrentNID Series card fiber port D/D information: Wave length 2
1.3.6.1.4.1.4756.20.502.20.1.1934ColumnnidFx1DDLinkLenRemoteBread-onlycurrentNID Series card fiber port D/D information: Link length
1.3.6.1.4.1.4756.20.502.20.1.1935ColumnnidFx1DDLenUnitRemoteBread-onlycurrentNID Series card fiber port D/D information: Length Unit
1.3.6.1.4.1.4756.20.502.20.1.1936ColumnnidFx1DDStatusRemoteBread-onlycurrentNID Series card fiber port D/D information: Status Support
1.3.6.1.4.1.4756.20.502.20.1.1937ColumnnidFx1DDRxSensRemoteBread-onlycurrentNID Series card fiber port D/D information: Rx Sensitivity
1.3.6.1.4.1.4756.20.502.20.1.1938ColumnnidFx1DDTxPWRRemoteBread-onlycurrentNID Series card fiber port D/D information: Tx power
1.3.6.1.4.1.4756.20.502.20.1.1939ColumnnidFx1DDRxPWRRemoteBread-onlycurrentNID Series card fiber port D/D information: Rx power
1.3.6.1.4.1.4756.20.502.20.1.1940ColumnnidFx1DDTempRemoteBread-onlycurrentNID Series card fiber port D/D information: Temperature in degree C
1.3.6.1.4.1.4756.20.502.20.1.1941ColumnnidFx1DDPWRMarginRemoteBread-onlycurrentNID Series card fiber port D/D information: Power margin
1.3.6.1.4.1.4756.20.502.20.1.1942ColumnnidFx1DDPWRLossRemoteBread-onlycurrentNID Series card fiber port D/D information: Power loss
1.3.6.1.4.1.4756.20.502.20.1.1943ColumnnidFx2DDRemoteBread-onlycurrentNID Series card fiber2 Digital Diagnostic function: 0:NO 1:Yes
1.3.6.1.4.1.4756.20.502.20.1.1944ColumnnidFx2DDVendorRemoteBread-onlycurrentNID Series card fiber2 D/D information: Vendor name
1.3.6.1.4.1.4756.20.502.20.1.1945ColumnnidFx2DDPartNoRemoteBread-onlycurrentNID Series card fiber2 D/D information: Vendor part number
1.3.6.1.4.1.4756.20.502.20.1.1946ColumnnidFx2DDFiberTypeRemoteBread-onlycurrentNID Series card fiber2 D/D information: Fiber Type
1.3.6.1.4.1.4756.20.502.20.1.1947ColumnnidFx2DDWaveLenRemoteBread-onlycurrentNID Series card fiber2 D/D information: Wave length 1
1.3.6.1.4.1.4756.20.502.20.1.1948ColumnnidFx2DDWaveLen2RemoteBread-onlycurrentNID Series card fiber2 D/D information: Wave length 2
1.3.6.1.4.1.4756.20.502.20.1.1949ColumnnidFx2DDLinkLenRemoteBread-onlycurrentNID Series card fiber2 D/D information: Link length
1.3.6.1.4.1.4756.20.502.20.1.1950ColumnnidFx2DDLenUnitRemoteBread-onlycurrentNID Series card fiber2 D/D information: Length Unit
1.3.6.1.4.1.4756.20.502.20.1.1951ColumnnidFx2DDStatusRemoteBread-onlycurrentNID Series card fiber2 D/D information: Status Support
1.3.6.1.4.1.4756.20.502.20.1.1952ColumnnidFx2DDRxSensRemoteBread-onlycurrentNID Series card fiber2 D/D information: Rx Sensitivity
1.3.6.1.4.1.4756.20.502.20.1.1953ColumnnidFx2DDTxPWRRemoteBread-onlycurrentNID Series card fiber2 D/D information: Tx power
1.3.6.1.4.1.4756.20.502.20.1.1954ColumnnidFx2DDRxPWRRemoteBread-onlycurrentNID Series card fiber2 D/D information: Rx power
1.3.6.1.4.1.4756.20.502.20.1.1955ColumnnidFx2DDTempRemoteBread-onlycurrentNID Series card fiber2 D/D information: Temperature in degree C
1.3.6.1.4.1.4756.20.502.20.1.1956ColumnnidFx2DDPWRMarginRemoteBread-onlycurrentNID Series card fiber2 D/D information: Power margin
1.3.6.1.4.1.4756.20.502.20.1.1957ColumnnidFx2DDPWRLossRemoteBread-onlycurrentNID Series card fiber2 D/D information: Power loss
1.3.6.1.4.1.4756.20.502.20.1.1958ColumnnidFx3DDRemoteBread-onlycurrentNID Series card fiber3 Digital Diagnostic function: 0:NO 1:Yes
1.3.6.1.4.1.4756.20.502.20.1.1959ColumnnidFx3DDVendorRemoteBread-onlycurrentNID Series card fiber3 D/D information: Vendor name
1.3.6.1.4.1.4756.20.502.20.1.1960ColumnnidFx3DDPartNoRemoteBread-onlycurrentNID Series card fiber32 D/D information: Vendor part number
1.3.6.1.4.1.4756.20.502.20.1.1961ColumnnidFx3DDFiberTypeRemoteBread-onlycurrentNID Series card fiber3 D/D information: Fiber Type
1.3.6.1.4.1.4756.20.502.20.1.1962ColumnnidFx3DDWaveLenRemoteBread-onlycurrentNID Series card fiber3 D/D information: Wave length 1
1.3.6.1.4.1.4756.20.502.20.1.1963ColumnnidFx3DDWaveLen2RemoteBread-onlycurrentNID Series card fiber3 D/D information: Wave length 2
1.3.6.1.4.1.4756.20.502.20.1.1964ColumnnidFx3DDLinkLenRemoteBread-onlycurrentNID Series card fiber3 D/D information: Link length
1.3.6.1.4.1.4756.20.502.20.1.1965ColumnnidFx3DDLenUnitRemoteBread-onlycurrentNID Series card fiber3 D/D information: Length Unit
1.3.6.1.4.1.4756.20.502.20.1.1966ColumnnidFx3DDStatusRemoteBread-onlycurrentNID Series card fiber3 D/D information: Status Support
1.3.6.1.4.1.4756.20.502.20.1.1967ColumnnidFx3DDRxSensRemoteBread-onlycurrentNID Series card fiber3 D/D information: Rx Sensitivity
1.3.6.1.4.1.4756.20.502.20.1.1968ColumnnidFx3DDTxPWRRemoteBread-onlycurrentNID Series card fiber3 D/D information: Tx power
1.3.6.1.4.1.4756.20.502.20.1.1969ColumnnidFx3DDRxPWRRemoteBread-onlycurrentNID Series card fiber3 D/D information: Rx power
1.3.6.1.4.1.4756.20.502.20.1.1970ColumnnidFx3DDTempRemoteBread-onlycurrentNID Series card fiber3 D/D information: Temperature in degree C
1.3.6.1.4.1.4756.20.502.20.1.1971ColumnnidFx3DDPWRMarginRemoteBread-onlycurrentNID Series card fiber3 D/D information: Power margin
1.3.6.1.4.1.4756.20.502.20.1.1972ColumnnidFx3DDPWRLossRemoteBread-onlycurrentNID Series card fiber3 D/D information: Power loss
1.3.6.1.4.1.4756.20.502.20.1.1973ColumnnidFx4DDRemoteBread-onlycurrentNID Series card fiber4 Digital Diagnostic function: 0:NO 1:Yes
1.3.6.1.4.1.4756.20.502.20.1.1974ColumnnidFx4DDVendorRemoteBread-onlycurrentNID Series card fiber4 D/D information: Vendor name
1.3.6.1.4.1.4756.20.502.20.1.1975ColumnnidFx4DDPartNoRemoteBread-onlycurrentNID Series card fiber4 D/D information: Vendor part number
1.3.6.1.4.1.4756.20.502.20.1.1976ColumnnidFx4DDFiberTypeRemoteBread-onlycurrentNID Series card fiber4 D/D information: Fiber Type
1.3.6.1.4.1.4756.20.502.20.1.1977ColumnnidFx4DDWaveLenRemoteBread-onlycurrentNID Series card fiber4 D/D information: Wave length 1
1.3.6.1.4.1.4756.20.502.20.1.1978ColumnnidFx4DDWaveLen2RemoteBread-onlycurrentNID Series card fiber4 D/D information: Wave length 2
1.3.6.1.4.1.4756.20.502.20.1.1979ColumnnidFx4DDLinkLenRemoteBread-onlycurrentNID Series card fiber4 D/D information: Link length
1.3.6.1.4.1.4756.20.502.20.1.1980ColumnnidFx4DDLenUnitRemoteBread-onlycurrentNID Series card fiber4 D/D information: Length Unit
1.3.6.1.4.1.4756.20.502.20.1.1981ColumnnidFx4DDStatusRemoteBread-onlycurrentNID Series card fiber4 D/D information: Status Support
1.3.6.1.4.1.4756.20.502.20.1.1982ColumnnidFx4DDRxSensRemoteBread-onlycurrentNID Series card fiber4 D/D information: Rx Sensitivity
1.3.6.1.4.1.4756.20.502.20.1.1983ColumnnidFx4DDTxPWRRemoteBread-onlycurrentNID Series card fiber4 D/D information: Tx power
1.3.6.1.4.1.4756.20.502.20.1.1984ColumnnidFx4DDRxPWRRemoteBread-onlycurrentNID Series card fiber4 D/D information: Rx power
1.3.6.1.4.1.4756.20.502.20.1.1985ColumnnidFx4DDTempRemoteBread-onlycurrentNID Series card fiber4 D/D information: Temperature in degree C
1.3.6.1.4.1.4756.20.502.20.1.1986ColumnnidFx4DDPWRMarginRemoteBread-onlycurrentNID Series card fiber4 D/D information: Power margin
1.3.6.1.4.1.4756.20.502.20.1.1987ColumnnidFx4DDPWRLossRemoteBread-onlycurrentNID Series card fiber4 D/D information: Power loss
1.3.6.1.4.1.4756.20.502.20.1.1988ColumnnidDeviceActiveRemoteBread-writecurrentNID Series card u-Ring device active 0: Disable 1: Enable
1.3.6.1.4.1.4756.20.502.20.1.1989ColumnnidSaveStartupCongRemoteBread-writecurrentNID Series card save start-up config 0: OFF 1: Action
1.3.6.1.4.1.4756.20.502.20.1.1990ColumnnidPortResetRemoteBread-writecurrentNID Series card port reset 0: OFF 1: Action
1.3.6.1.4.1.4756.20.502.20.1.1991ColumnnidSetDefaultRemoteBread-writecurrentNID Series card set to default config 0: OFF 1: Action
1.3.6.1.4.1.4756.20.502.20.1.1992ColumnnidSetDefault2RemoteBread-writecurrentNID Series card set to default config (Without OAM) 0: OFF 1: Action
1.3.6.1.4.1.4756.20.502.20.1.1993ColumnnidClearPortCounterRemoteBread-writecurrentNID Series card clear port counter: 0: Off 1: Action
1.3.6.1.4.1.4756.20.502.20.1.1994ColumnnidClearOAMCounterRemoteBread-writecurrentNID Series card Clear OAM Counter: 0: Off 1: Action
1.3.6.1.4.1.4756.20.502.20.1.1995ColumnnidSTPStatisticsPortClearCounterRemoteBread-writecurrentNID Series card STP Port Statistics: Clear Counters 0: OFff 1: Action
1.3.6.1.4.1.4756.20.502.20.1.1996ColumnnidAlarmRemoteBread-onlycurrentNID Series card Alarm led status: 0: Off 1: On
1.3.6.1.4.1.4756.20.502.20.1.1997ColumnnidTest1RemoteBread-onlycurrentNID Series card Test1 led status: 0: Off 1: On
1.3.6.1.4.1.4756.20.502.20.1.1998ColumnnidTest2RemoteBread-onlycurrentNID Series card Test2 led status: 0: Off 1: On
1.3.6.1.4.1.4756.20.600Nodeoab15Cards
1.3.6.1.4.1.4756.20.600.20Tableoab15Tablenot-accessiblecurrentA list of local OAB15 card entries. The number of entries is oab15-No-L.
1.3.6.1.4.1.4756.20.600.20.1Rowoab15Entrynot-accessiblecurrentAn entry containing management information applicable to a particular local FRM220 OAB15 card.
1.3.6.1.4.1.4756.20.600.20.1.1Columnoab15ChassisIndexread-onlycurrentA unique value for each local card. It is the chassis location number.
1.3.6.1.4.1.4756.20.600.20.1.2Columnoab15SlotIndexread-onlycurrentA unique value for each local card. It is the slot location number.
1.3.6.1.4.1.4756.20.600.20.1.3Columnoab15CardHWVerread-onlycurrentLocal FRM220 OAB15 card hardware version x.xxx
1.3.6.1.4.1.4756.20.600.20.1.4Columnoab15CardFWVerread-onlycurrentLocal FRM220 OAB15 card firmware version x.xxx
1.3.6.1.4.1.4756.20.600.20.1.5Columnoab15CardCPLDVerread-onlycurrentLocal FRM220 OAB15 card CPLD version x.xxx
1.3.6.1.4.1.4756.20.600.20.1.6Columnoab15CardFPGAVerread-onlycurrentLocal FRM220 OAB15 card FPGA version x.xxx
1.3.6.1.4.1.4756.20.600.20.1.7Columnoab15PumpCurrentStatusread-onlycurrentLocal FRM220 OAB15 card pump current status (Unit is mA)
1.3.6.1.4.1.4756.20.600.20.1.8Columnoab15OutputPowerStatusread-onlycurrentLocal FRM220 OAB15 card output power status (Unit is dBm)
1.3.6.1.4.1.4756.20.600.20.1.9Columnoab15PumpPowerStatusread-onlycurrentLocal FRM220 OAB15 card pump power status (Unit is mW)
1.3.6.1.4.1.4756.20.600.20.1.10Columnoab15TemperatureStatusread-onlycurrentLocal FRM220 OAB15 card temperature Status (Unit is degree C)
1.3.6.1.4.1.4756.20.600.20.1.11Columnoab15OutputPowerread-writecurrentLocal FRM220 OAB15 card set output power(Unit is dBm) Input range is from 10 to 15
1.3.6.1.4.1.4756.20.600.20.1.12Columnoab15DeviceActiveread-writecurrentLocal FRM220 OAB15 card device active: 0:Disable 1:Enable
1.3.6.1.4.1.4756.20.600.20.1.13Columnoab15DeviceResetread-writecurrentLocal FRM220 OAB15 card device reset: 0:Off 1:Action
1.3.6.1.4.1.4756.20.600.20.1.14Columnoab15SetDefaultread-onlycurrentLocal FRM220 OAB15 set to default: 0:Off 1:Action
1.3.6.1.4.1.4756.20.600.20.1.15Columnoab15LosAssert110GSXXSlotread-writecurrentLocal FRM220 OAB15 Los Assert1 10G-SXX Slot No.: Please enter the slot number '2'~'20' or 'none'
1.3.6.1.4.1.4756.20.600.20.1.16Columnoab15LosAssert110GSXXPropagationread-writecurrentLocal FRM220 OAB15 Assert1 10G-SXX LOS Propagation: 0:line 1:Primary & Second
1.3.6.1.4.1.4756.20.600.20.1.17Columnoab15LosAssert210GSXXSlotread-writecurrentLocal FRM220 OAB15 Los Assert2 10G-SXX Slot No.: Please enter the slot number '2'~'20' or 'none'
1.3.6.1.4.1.4756.20.600.20.1.18Columnoab15LosAssert210GSXXPropagationread-writecurrentLocal FRM220 OAB15 Assert2 10G-SXX LOS Propagation: 0:line 1:Primary & Second
1.3.6.1.4.1.4756.20.600.20.1.19Columnoab15LosAssert310GSXXSlotread-writecurrentLocal FRM220 OAB15 Los Assert3 10G-SXX Slot No.: Please enter the slot number '2'~'20' or 'none'
1.3.6.1.4.1.4756.20.600.20.1.20Columnoab15LosAssert310GSXXPropagationread-writecurrentLocal FRM220 OAB15 Assert3 10G-SXX LOS Propagation: 0:line 1:Primary & Second
1.3.6.1.4.1.4756.20.600.20.1.21Columnoab15LosAssert410GSXXSlotread-writecurrentLocal FRM220 OAB15 Los Assert4 10G-SXX Slot No.: Please enter the slot number '2'~'20' or 'none'
1.3.6.1.4.1.4756.20.600.20.1.22Columnoab15LosAssert410GSXXPropagationread-writecurrentLocal FRM220 OAB15 Assert4 10G-SXX LOS Propagation: 0:line 1:Primary & Second
1.3.6.1.4.1.4756.20.600.20.1.23Columnoab15Alarmread-onlycurrentLocal FRM220 OAB15 Alarm: 0:Pump drive current is over limit. 1:Output power is less than setting output power(< 1dB) 2:Output power is over the setting output…
1.3.6.1.4.1.4756.20.600.20.1.24Columnoab15Mgmtread-onlycurrentLocal FRM220 OAB15 Module Condition Active: 0:Inactive 1:Active
1.3.6.1.4.1.4756.20.610Nodeeoe1GSLocalCards
1.3.6.1.4.1.4756.20.610.20Tableeoe1GSLocalTablenot-accessiblecurrentA list of local FRM220-EOE1/GS card entries. The number of entries is eoe1GS-No-L.
1.3.6.1.4.1.4756.20.610.20.1Roweoe1GSLocalEntrynot-accessiblecurrentAn entry containing management information applicable to a particular local FRM220-Eoe1GS series card.
1.3.6.1.4.1.4756.20.610.20.1.1Columneoe1GSChassisIndexLocalread-onlycurrentA unique value for each card. It starts from 0 to 9 contiguously.
1.3.6.1.4.1.4756.20.610.20.1.2Columneoe1GSSlotIndexLocalread-onlycurrentA unique value for each card. It starts from 1 to 20 contiguously.
1.3.6.1.4.1.4756.20.610.20.1.3Columneoe1GSCardHWVerLocalread-onlycurrentEoe1/GS card hardware version x.xxx
1.3.6.1.4.1.4756.20.610.20.1.4Columneoe1GSCardFWVerLocalread-onlycurrentEoe1/GS card firmware version x.xxx
1.3.6.1.4.1.4756.20.610.20.1.5Columneoe1GSCardCPLDVerLocalread-onlycurrentEoe1/GS card CPLD version x.xxx
1.3.6.1.4.1.4756.20.610.20.1.6Columneoe1GSCardFPGAVerLocalread-onlycurrentEoe1/GS card FPGA version x.xxx
1.3.6.1.4.1.4756.20.610.20.1.7Columneoe1GSPortResetLocalread-writecurrentEoe1/GS card system status: 0:Off 1:Trigger
1.3.6.1.4.1.4756.20.610.20.1.8Columneoe1GSSetToDefaultLocalread-writecurrentEoe1/GS card port set to default: 0:Off 1:Trigger
1.3.6.1.4.1.4756.20.610.20.1.9Columneoe1GSLOSLocalread-onlycurrentEoe1/GS card LOS status: 0:No 1:Yes
1.3.6.1.4.1.4756.20.610.20.1.10Columneoe1GSLOFLocalread-onlycurrentEoe1/GS card LOF status: 0:No 1:Yes
1.3.6.1.4.1.4756.20.610.20.1.11Columneoe1GSAISLocalread-onlycurrentEoe1/GS card AIS status: 0:No 1:Yes
1.3.6.1.4.1.4756.20.610.20.1.12Columneoe1GSRAILocalread-onlycurrentEoe1/GS card RAI status: 0:No 1:Yes
1.3.6.1.4.1.4756.20.610.20.1.13Columneoe1GSCRCLocalread-onlycurrentEoe1/GS card CRC status: 0:No 1:Yes
1.3.6.1.4.1.4756.20.610.20.1.14Columneoe1GSBPVLocalread-onlycurrentEoe1/GS card BPV status: 0:No 1:Yes
1.3.6.1.4.1.4756.20.610.20.1.15Columneoe1GSLoopStatusLocalread-onlycurrentEoe1/GS card Loop status: 0:No 1:Yes
1.3.6.1.4.1.4756.20.610.20.1.16Columneoe1GSE1ModeLocalread-writecurrentEoe1/GS card E1 mode: 0:Unframe 1:Frame
1.3.6.1.4.1.4756.20.610.20.1.17Columneoe1GSE1LoopBackLocalread-writecurrentEoe1/GS card E1 loopback : 0:OFF 1:LLB 2:RLB
1.3.6.1.4.1.4756.20.610.20.1.18Columneoe1GSE1LoopDetectionLocalread-writecurrentEoe1/GS card E1 loop detection: 0:Disable 1:Enalbe
1.3.6.1.4.1.4756.20.610.20.1.19Columneoe1GSE1HDLCLocalread-writecurrentEoe1/GS Series card E1 HDLC: 0:Inverse 1:Consisten
1.3.6.1.4.1.4756.20.610.20.1.20Columneoe1GSTimingSourceLocalread-writecurrentEoe1/GS card timing source: 0:Recovery from E1 receive 1:Internal oscillator
1.3.6.1.4.1.4756.20.610.20.1.21Columneoe1GSFailOverLocalread-writecurrentEoe1/GS card failover: 0:Disalbe 1:Enable
1.3.6.1.4.1.4756.20.610.20.1.22Columneoe1GSEncapsulationLocalread-writecurrentEoe1/GS card encapsulation: 0:GFP 1:HDLC
1.3.6.1.4.1.4756.20.610.20.1.23Columneoe1GSNetManageLocalread-writecurrentEoe1/GS Series card net manage: 0:Disable 1:Enable
1.3.6.1.4.1.4756.20.610.20.1.24Columneoe1GSFxModelLocalread-onlycurrentEoe1/GS card SFP model: 0:No Model 1:OnLine
1.3.6.1.4.1.4756.20.610.20.1.25Columneoe1GSFxSDLocalread-onlycurrentEoe1/GS card fiber Signal Detection: 0:Fiber Unplugged 1:Signal Detected
1.3.6.1.4.1.4756.20.610.20.1.26Columneoe1GSFxLaserLocalread-onlycurrentEoe1/GS card fiber Laser status: 0:Normal 1:error
1.3.6.1.4.1.4756.20.610.20.1.27Columneoe1GSFxLinkLocalread-onlycurrentEoe1/GS card fiber link status: 0:Link Down 1:Link Up
1.3.6.1.4.1.4756.20.610.20.1.28Columneoe1GSFxActiveLocalread-writecurrentEoe1/GS card fiber port active: 0:disable 1:enable
1.3.6.1.4.1.4756.20.610.20.1.29Columneoe1GSFxLaserOutputLocalread-writecurrentEoe1/GS card fiber Laser Output active: 0:disable 1:enable
1.3.6.1.4.1.4756.20.610.20.1.30Columneoe1GSFxALSLocalread-writecurrentEoe1/GS card fiber Auto Laser Shutdown active: 0:OFF 1:ON
1.3.6.1.4.1.4756.20.610.20.1.31Columneoe1GSFxFlowCtrlLocalread-writecurrentEoe1/GS card fiber Flow Control active: 0:disable 1:enable
1.3.6.1.4.1.4756.20.610.20.1.32Columneoe1GSFxTagLocalread-writecurrentEoe1/GS card fiber Tag active: 0:UnTag 1:Tag 2:No Touch
1.3.6.1.4.1.4756.20.610.20.1.33Columneoe1GSFxTagInsertLocalread-writecurrentEoe1/GS card fiber Tag Insert active: 0:Disable 1:Enable
1.3.6.1.4.1.4756.20.610.20.1.34Columneoe1GSBandwidthFUNLocalread-writecurrentEoe1/GS card bandwidth mode: 1:disable(0), 2:32k*N(0~255)(1), 3:521k*N(0~200)(2),
1.3.6.1.4.1.4756.20.610.20.1.35Columneoe1GSBandwidthLocalread-writecurrentEoe1/GS bandwidth: bandwidth mode is 32k*N , The bandwidth is restricted to 0 ~ 255 bandwidth mode is 512k*N , The bandwidth is restricted to 0 ~ 200
1.3.6.1.4.1.4756.20.610.20.1.36Columneoe1GSBandwidthSpeedLocalread-onlycurrentEoe1/GS bandwidthspeed:
1.3.6.1.4.1.4756.20.610.20.1.37Columneoe1GSVlanFUNLocalread-writecurrentEoe1/GS card Vlan mode: 0:Disable 1:Enable
1.3.6.1.4.1.4756.20.610.20.1.38Columneoe1GSVlanIDLocalread-writecurrentEoe1/GS card VLAN ID: The ID is restricted to 1 ~ 4095
1.3.6.1.4.1.4756.20.610.20.1.39Columneoe1GSRemoteLinkLocalread-onlycurrentEoe1/GS card remote link status: 0:Down 1:Up
1.3.6.1.4.1.4756.20.610.20.1.40Columneoe1GSRemotePWRLocalread-onlycurrentEoe1/GS card remote power status: 0:Normal 1:Power Off
1.3.6.1.4.1.4756.20.610.20.1.41Columneoe1GSBertFUNLocalread-writecurrentEoe1/GS card bert mode: 0:Disable 1:Enable
1.3.6.1.4.1.4756.20.610.20.1.42Columneoe1GSBertClearLocalread-writecurrentEoe1/GS card bert data clear: 0:Normal 1:Clear
1.3.6.1.4.1.4756.20.610.20.1.43Columneoe1GSLSBToESLocalread-onlycurrentEoe1/GS card, errored seconds of BERT result.
1.3.6.1.4.1.4756.20.610.20.1.44Columneoe1GSLSBToSESLocalread-onlycurrentEoe1/GS card, severely errored seconds of BERT result.
1.3.6.1.4.1.4756.20.610.20.1.45Columneoe1GSRmonFUNLocalread-writecurrentEoe1/GS card Rmon mode: 0:Disable 1:Enable
1.3.6.1.4.1.4756.20.610.20.1.46Columneoe1GSRmonRxPKTClearLocalread-writecurrentEoe1/GS card rmon rx packet clear: 0:Normal 1:Clear
1.3.6.1.4.1.4756.20.610.20.1.47Columneoe1GSRmonRxByteClearLocalread-writecurrentEoe1/GS card rmon rx byte clear: 0:Normal 1:Clear
1.3.6.1.4.1.4756.20.610.20.1.48Columneoe1GSRmonRxPKTLocalread-onlycurrentEoe1/GS card RMON Rx packet counter.
1.3.6.1.4.1.4756.20.610.20.1.49Columneoe1GSRmonRxByteLocalread-onlycurrentEoe1/GS card RMON Rx byte counter.
1.3.6.1.4.1.4756.20.610.20.1.50Columneoe1GSFxDDVenderNameLocalread-onlycurrentEoe1/GS card Fiber SFP Vender Name.
1.3.6.1.4.1.4756.20.610.20.1.51Columneoe1GSFxDDVenderPartNoLocalread-onlycurrentEoe1/GS card Fiber SFP Vender Part Number.
1.3.6.1.4.1.4756.20.610.20.1.52Columneoe1GSFxDDSFPTypeLocalread-onlycurrentEoe1/GS card Fiber SFP Type . 0:Multi Mode 1:Single Mode 2:None
1.3.6.1.4.1.4756.20.610.20.1.53Columneoe1GSFxDDWaveLength1Localread-onlycurrentEoe1/GS card Fiber SFP Wave Length 1.
1.3.6.1.4.1.4756.20.610.20.1.54Columneoe1GSFxDDWaveLength2Localread-onlycurrentEoe1/GS card Fiber SFP Wave Length 2.
1.3.6.1.4.1.4756.20.610.20.1.55Columneoe1GSFxDDLinkLengthLocalread-onlycurrentEoe1/GS card Fiber SFP Link Length.
1.3.6.1.4.1.4756.20.610.20.1.56Columneoe1GSFxDDModelIDLocalread-onlycurrentEoe1/GS card Fiber SFP Model ID.
1.3.6.1.4.1.4756.20.610.20.1.57Columneoe1GSFxDDVersionLocalread-onlycurrentEoe1/GS card Fiber SFP Model Version.
1.3.6.1.4.1.4756.20.610.20.1.58Columneoe1GSFxDDModelTypeLocalread-onlycurrentEoe1/GS card Fiber SFP Model Type.
1.3.6.1.4.1.4756.20.610.20.1.59Columneoe1GSFxDDTxPowerLocalread-onlycurrentEoe1/GS card Fiber SFP Digital/Diagnostic Transmit Power.
1.3.6.1.4.1.4756.20.610.20.1.60Columneoe1GSFxDDRxPowerLocalread-onlycurrentEoe1/GS card Fiber SFP Digital/Diagnostic Receive Power.
1.3.6.1.4.1.4756.20.610.20.1.61Columneoe1GSFxDDRxSensLocalread-onlycurrentEoe1/GS card Fiber SFP Digital/Diagnostic Receive Sensitivity.
1.3.6.1.4.1.4756.20.610.20.1.62Columneoe1GSFxDDRxPwrMarginLocalread-onlycurrentEoe1/GS card Fiber SFP Digital/Diagnostic Receive Power Margin.
1.3.6.1.4.1.4756.20.610.20.1.63Columneoe1GSFxDDTempLocalread-onlycurrentEoe1/GS card Fiber SFP Digital/Diagnostic Temperature.
1.3.6.1.4.1.4756.20.610.20.1.64Columneoe1GSFxDDBIASLocalread-onlycurrentEoe1/GS card Fiber SFP Digital/Diagnostic BIAS.
1.3.6.1.4.1.4756.20.610.20.1.65Columneoe1GSFxDDVoltageLocalread-onlycurrentEoe1/GS card Fiber SFP Digital/Diagnostic Voltage.
1.3.6.1.4.1.4756.20.611Nodeeoe1GSRemoteCards
1.3.6.1.4.1.4756.20.611.20Tableeoe1GSRemoteTablenot-accessiblecurrentA list of local FRM220-EOE1/GS card entries. The number of entries is eoe1GS-No-L.
1.3.6.1.4.1.4756.20.611.20.1Roweoe1GSRemoteEntrynot-accessiblecurrentAn entry containing management information applicable to a particular local FRM220-Eoe1GS series card.
1.3.6.1.4.1.4756.20.611.20.1.1Columneoe1GSChassisIndexRemoteread-onlycurrentA unique value for each card. It starts from 0 to 9 contiguously.
1.3.6.1.4.1.4756.20.611.20.1.2Columneoe1GSSlotIndexRemoteread-onlycurrentA unique value for each card. It starts from 1 to 20 contiguously.
1.3.6.1.4.1.4756.20.611.20.1.3Columneoe1GSCardHWVerRemoteread-onlycurrentEoe1/GS card hardware version x.xxx
1.3.6.1.4.1.4756.20.611.20.1.4Columneoe1GSCardFWVerRemoteread-onlycurrentEoe1/GS card firmware version x.xxx
1.3.6.1.4.1.4756.20.611.20.1.5Columneoe1GSCardCPLDVerRemoteread-onlycurrentEoe1/GS card CPLD version x.xxx
1.3.6.1.4.1.4756.20.611.20.1.6Columneoe1GSCardFPGAVerRemoteread-onlycurrentEoe1/GS card FPGA version x.xxx
1.3.6.1.4.1.4756.20.611.20.1.7Columneoe1GSPortResetRemoteread-writecurrentEoe1/GS card system status: 0:Off 1:Trigger
1.3.6.1.4.1.4756.20.611.20.1.8Columneoe1GSSetToDefaultRemoteread-writecurrentEoe1/GS card port set to default: 0:Off 1:Trigger
1.3.6.1.4.1.4756.20.611.20.1.9Columneoe1GSLOSRemoteread-onlycurrentEoe1/GS card LOS status: 0:No 1:Yes
1.3.6.1.4.1.4756.20.611.20.1.10Columneoe1GSLOFRemoteread-onlycurrentEoe1/GS card LOF status: 0:No 1:Yes
1.3.6.1.4.1.4756.20.611.20.1.11Columneoe1GSAISRemoteread-onlycurrentEoe1/GS card AIS status: 0:No 1:Yes
1.3.6.1.4.1.4756.20.611.20.1.12Columneoe1GSRAIRemoteread-onlycurrentEoe1/GS card RAI status: 0:No 1:Yes
1.3.6.1.4.1.4756.20.611.20.1.13Columneoe1GSCRCRemoteread-onlycurrentEoe1/GS card CRC status: 0:No 1:Yes
1.3.6.1.4.1.4756.20.611.20.1.14Columneoe1GSBPVRemoteread-onlycurrentEoe1/GS card BPV status: 0:No 1:Yes
1.3.6.1.4.1.4756.20.611.20.1.15Columneoe1GSLoopStatusRemoteread-onlycurrentEoe1/GS card Loop status: 0:No 1:Yes
1.3.6.1.4.1.4756.20.611.20.1.16Columneoe1GSE1ModeRemoteread-writecurrentEoe1/GS card E1 mode: 0:Unframe 1:Frame
1.3.6.1.4.1.4756.20.611.20.1.17Columneoe1GSE1LoopDetectionRemoteread-writecurrentEoe1/GS card E1 loop detection: 0:Disable 1:Enalbe
1.3.6.1.4.1.4756.20.611.20.1.18Columneoe1GSE1HDLCRemoteread-writecurrentEoe1/GS Series card E1 HDLC: 0:Inverse 1:Consisten
1.3.6.1.4.1.4756.20.611.20.1.19Columneoe1GSTimingSourceRemoteread-writecurrentEoe1/GS card timing source: 0:Recovery from E1 receive 1:Internal oscillator
1.3.6.1.4.1.4756.20.611.20.1.20Columneoe1GSFailOverRemoteread-writecurrentEoe1/GS card failover: 0:Disalbe 1:Enable
1.3.6.1.4.1.4756.20.611.20.1.21Columneoe1GSEncapsulationRemoteread-writecurrentEoe1/GS card encapsulation: 0:GFP 1:HDLC
1.3.6.1.4.1.4756.20.611.20.1.22Columneoe1GSNetManageRemoteread-writecurrentEoe1/GS Series card net manage: 0:Disable 1:Enable
1.3.6.1.4.1.4756.20.611.20.1.23Columneoe1GSFxModelRemoteread-onlycurrentEoe1/GS card SFP model: 0:No Model 1:OnLine
1.3.6.1.4.1.4756.20.611.20.1.24Columneoe1GSFxSDRemoteread-onlycurrentEoe1/GS card fiber Signal Detection: 0:Fiber Unplugged 1:Signal Detected
1.3.6.1.4.1.4756.20.611.20.1.25Columneoe1GSFxLaserRemoteread-onlycurrentEoe1/GS card fiber Laser status: 0:Normal 1:error
1.3.6.1.4.1.4756.20.611.20.1.26Columneoe1GSFxLinkRemoteread-onlycurrentEoe1/GS card fiber link status: 0:Link Down 1:Link Up
1.3.6.1.4.1.4756.20.611.20.1.27Columneoe1GSFxActiveRemoteread-writecurrentEoe1/GS card fiber port active: 0:disable 1:enable
1.3.6.1.4.1.4756.20.611.20.1.28Columneoe1GSFxLaserOutputRemoteread-writecurrentEoe1/GS card fiber Laser Output active: 0:disable 1:enable
1.3.6.1.4.1.4756.20.611.20.1.29Columneoe1GSFxALSRemoteread-writecurrentEoe1/GS card fiber Auto Laser Shutdown active: 0:OFF 1:ON
1.3.6.1.4.1.4756.20.611.20.1.30Columneoe1GSFxFlowCtrlRemoteread-writecurrentEoe1/GS card fiber Flow Control active: 0:disable 1:enable
1.3.6.1.4.1.4756.20.611.20.1.31Columneoe1GSFxTagRemoteread-writecurrentEoe1/GS card fiber Tag active: 0:UnTag 1:Tag 2:No Touch
1.3.6.1.4.1.4756.20.611.20.1.32Columneoe1GSFxTagInsertRemoteread-writecurrentEoe1/GS card fiber Tag Insert active: 0:Disable 1:Enable
1.3.6.1.4.1.4756.20.611.20.1.33Columneoe1GSBandwidthFUNRemoteread-writecurrentEoe1/GS card bandwidth mode: 1:disable(0), 2:32k*N(0~255)(1), 3:521k*N(0~200)(2),
1.3.6.1.4.1.4756.20.611.20.1.34Columneoe1GSBandwidthRemoteread-writecurrentEoe1/GS bandwidth: bandwidth mode is 32k*N , The bandwidth is restricted to 0 ~ 255 bandwidth mode is 512k*N , The bandwidth is restricted to 0 ~ 200
1.3.6.1.4.1.4756.20.611.20.1.35Columneoe1GSBandwidthSpeedRemoteread-onlycurrentEoe1/GS bandwidthspeed:
1.3.6.1.4.1.4756.20.611.20.1.36Columneoe1GSVlanFUNRemoteread-writecurrentEoe1/GS card Vlan mode: 0:Disable 1:Enable
1.3.6.1.4.1.4756.20.611.20.1.37Columneoe1GSVlanIDRemoteread-writecurrentEoe1/GS card VLAN ID: The ID is restricted to 1 ~ 4095
1.3.6.1.4.1.4756.20.611.20.1.38Columneoe1GSRemoteLinkRemoteread-onlycurrentEoe1/GS card remote link status: 0:Down 1:Up
1.3.6.1.4.1.4756.20.611.20.1.39Columneoe1GSRemotePWRRemoteread-onlycurrentEoe1/GS card remote power status: 0:Normal 1:Power Off
1.3.6.1.4.1.4756.20.611.20.1.40Columneoe1GSRmonFUNRemoteread-writecurrentEoe1/GS card Rmon mode: 0:Disable 1:Enable
1.3.6.1.4.1.4756.20.611.20.1.41Columneoe1GSRmonRxPKTClearRemoteread-writecurrentEoe1/GS card rmon rx packet clear: 0:Normal 1:Clear
1.3.6.1.4.1.4756.20.611.20.1.42Columneoe1GSRmonRxByteClearRemoteread-writecurrentEoe1/GS card rmon rx byte clear: 0:Normal 1:Clear
1.3.6.1.4.1.4756.20.611.20.1.43Columneoe1GSRmonRxPKTRemoteread-onlycurrentEoe1/GS card RMON Rx packet counter.
1.3.6.1.4.1.4756.20.611.20.1.44Columneoe1GSRmonRxByteRemoteread-onlycurrentEoe1/GS card RMON Rx byte counter.
1.3.6.1.4.1.4756.20.611.20.1.45Columneoe1GSFxDDVenderNameRemoteread-onlycurrentEoe1/GS card Fiber SFP Vender Name.
1.3.6.1.4.1.4756.20.611.20.1.46Columneoe1GSFxDDVenderPartNoRemoteread-onlycurrentEoe1/GS card Fiber SFP Vender Part Number.
1.3.6.1.4.1.4756.20.611.20.1.47Columneoe1GSFxDDSFPTypeRemoteread-onlycurrentEoe1/GS card Fiber SFP Vender Part Number. 0:Multi Mode 1:Single Mode 2:None
1.3.6.1.4.1.4756.20.611.20.1.48Columneoe1GSFxDDWaveLength1Remoteread-onlycurrentEoe1/GS card Fiber SFP Wave Length 1.
1.3.6.1.4.1.4756.20.611.20.1.49Columneoe1GSFxDDWaveLength2Remoteread-onlycurrentEoe1/GS card Fiber SFP Wave Length 2.
1.3.6.1.4.1.4756.20.611.20.1.50Columneoe1GSFxDDLinkLengthRemoteread-onlycurrentEoe1/GS card Fiber SFP Link Length.
1.3.6.1.4.1.4756.20.611.20.1.51Columneoe1GSFxDDModelIDRemoteread-onlycurrentEoe1/GS card Fiber SFP Model ID.
1.3.6.1.4.1.4756.20.611.20.1.52Columneoe1GSFxDDVersionRemoteread-onlycurrentEoe1/GS card Fiber SFP Model Version.
1.3.6.1.4.1.4756.20.611.20.1.53Columneoe1GSFxDDModelTypeRemoteread-onlycurrentEoe1/GS card Fiber SFP Model Type.
1.3.6.1.4.1.4756.20.611.20.1.54Columneoe1GSFxDDTxPowerRemoteread-onlycurrentEoe1/GS card Fiber SFP Digital/Diagnostic Transmit Power.
1.3.6.1.4.1.4756.20.611.20.1.55Columneoe1GSFxDDRxPowerRemoteread-onlycurrentEoe1/GS card Fiber SFP Digital/Diagnostic Receive Power.
1.3.6.1.4.1.4756.20.611.20.1.56Columneoe1GSFxDDRxSensRemoteread-onlycurrentEoe1/GS card Fiber SFP Digital/Diagnostic Receive Sensitivity.
1.3.6.1.4.1.4756.20.611.20.1.57Columneoe1GSFxDDRxPwrMarginRemoteread-onlycurrentEoe1/GS card Fiber SFP Digital/Diagnostic Receive Power Margin.
1.3.6.1.4.1.4756.20.611.20.1.58Columneoe1GSFxDDTempRemoteread-onlycurrentEoe1/GS card Fiber SFP Digital/Diagnostic Temperature.
1.3.6.1.4.1.4756.20.611.20.1.59Columneoe1GSFxDDBIASRemoteread-onlycurrentEoe1/GS card Fiber SFP Digital/Diagnostic BIAS.
1.3.6.1.4.1.4756.20.611.20.1.60Columneoe1GSFxDDVoltageRemoteread-onlycurrentEoe1/GS card Fiber SFP Digital/Diagnostic Voltage.
1.3.6.1.4.1.4756.20.620Nodef40G1Q4SCards
1.3.6.1.4.1.4756.20.620.20Tablef40G1Q4STablenot-accessiblecurrentA list of local FRM220-40G1Q4S card entries. The number of entries is f40G1Q4S-No-L.
1.3.6.1.4.1.4756.20.620.20.1Rowf40G1Q4SEntrynot-accessiblecurrentAn entry containing management information applicable to a particular local FRM220-40G1Q4S series card.
1.3.6.1.4.1.4756.20.620.20.1.1Columnf40G1Q4SChassisIndexread-onlycurrentA unique value for each card. It starts from 0 to 9 contiguously.
1.3.6.1.4.1.4756.20.620.20.1.2Columnf40G1Q4SSlotIndexread-onlycurrentA unique value for each card. It starts from 1 to 20 contiguously.
1.3.6.1.4.1.4756.20.620.20.1.3Columnf40G1Q4SCardHWVerread-onlycurrent40G1Q4S card hardware version x.xxx
1.3.6.1.4.1.4756.20.620.20.1.4Columnf40G1Q4SCardFWVerread-onlycurrent40G1Q4S card firmware version x.xxx
1.3.6.1.4.1.4756.20.620.20.1.5Columnf40G1Q4SCardCPLDVerread-onlycurrent40G1Q4S card CPLD version x.xxx
1.3.6.1.4.1.4756.20.620.20.1.6Columnf40G1Q4SCardFPGAVerread-onlycurrent40G1Q4S card FPGA version x.xxx
1.3.6.1.4.1.4756.20.620.20.1.7Columnf40G1Q4SPortResetread-writecurrent40G1Q4S card system status: 0:Off 1:Trigger
1.3.6.1.4.1.4756.20.620.20.1.8Columnf40G1Q4SSetToDefaultread-writecurrent40G1Q4S card port set to default: 0:Off 1:Trigger
1.3.6.1.4.1.4756.20.620.20.1.9Columnf40G1Q4SQSFPP1Presentread-onlycurrent40G1Q4S QSFP Plus 1 Port Presented. 0:No 1:Have
1.3.6.1.4.1.4756.20.620.20.1.10Columnf40G1Q4SQSFPP2Presentread-onlycurrent40G1Q4S QSFP Plus 2 Port Presented. 0:No 1:Have
1.3.6.1.4.1.4756.20.620.20.1.11Columnf40G1Q4SQSFPP3Presentread-onlycurrent40G1Q4S QSFP Plus 3 Port Presented. 0:No 1:Have
1.3.6.1.4.1.4756.20.620.20.1.12Columnf40G1Q4SQSFPP4Presentread-onlycurrent40G1Q4S QSFP Plus 4 Port Presented. 0:No 1:Have
1.3.6.1.4.1.4756.20.620.20.1.13Columnf40G1Q4SSFPP1Presentread-onlycurrent40G1Q4S SFP Plus 4 Port Presented. 0:No 1:Have
1.3.6.1.4.1.4756.20.620.20.1.14Columnf40G1Q4SSFPP2Presentread-onlycurrent40G1Q4S SFP Plus 2 Port Presented. 0:No 1:Have
1.3.6.1.4.1.4756.20.620.20.1.15Columnf40G1Q4SSFPP3Presentread-onlycurrent40G1Q4S SFP Plus 3 Port Presented. 0:No 1:Have
1.3.6.1.4.1.4756.20.620.20.1.16Columnf40G1Q4SSFPP4Presentread-onlycurrent40G1Q4S SFP Plus 4 Port Presented. 0:No 1:Have
1.3.6.1.4.1.4756.20.620.20.1.17Columnf40G1Q4SQSFPP1DDMread-onlycurrent40G1Q4S QSFP Plus 1 Port Digital Diagnostic Monitor. 0:No 1:Yes
1.3.6.1.4.1.4756.20.620.20.1.18Columnf40G1Q4SQSFPP2DDMread-onlycurrent40G1Q4S QSFP Plus 2 Port Digital Diagnostic Monitor. 0:No 1:Yes
1.3.6.1.4.1.4756.20.620.20.1.19Columnf40G1Q4SQSFPP3DDMread-onlycurrent40G1Q4S QSFP Plus 3 Port Digital Diagnostic Monitor. 0:No 1:Yes
1.3.6.1.4.1.4756.20.620.20.1.20Columnf40G1Q4SQSFPP4DDMread-onlycurrent40G1Q4S QSFP Plus 4 Port Digital Diagnostic Monitor. 0:No 1:Yes
1.3.6.1.4.1.4756.20.620.20.1.21Columnf40G1Q4SSFPP1DDMread-onlycurrent40G1Q4S SFP Plus 1 Port Digital Diagnostic Monitor. 0:No 1:Yes
1.3.6.1.4.1.4756.20.620.20.1.22Columnf40G1Q4SSFPP2DDMread-onlycurrent40G1Q4S SFP Plus 2 Port Digital Diagnostic Monitor. 0:No 1:Yes
1.3.6.1.4.1.4756.20.620.20.1.23Columnf40G1Q4SSFPP3DDMread-onlycurrent40G1Q4S SFP Plus 3 Port Digital Diagnostic Monitor. 0:No 1:Yes
1.3.6.1.4.1.4756.20.620.20.1.24Columnf40G1Q4SSFPP4DDMread-onlycurrent40G1Q4S SFP Plus 4 Port Digital Diagnostic Monitor. 0:No 1:yes
1.3.6.1.4.1.4756.20.620.20.1.25Columnf40G1Q4SQSFPP1TxFaultread-onlycurrent40G1Q4S QSFP Plus 1 Port Transceiver Failure. 0:Normal 1:Failure
1.3.6.1.4.1.4756.20.620.20.1.26Columnf40G1Q4SQSFPP2TxFaultread-onlycurrent40G1Q4S QSFP Plus 2 Port Transceiver Failure. 0:Normal 1:Failure
1.3.6.1.4.1.4756.20.620.20.1.27Columnf40G1Q4SQSFPP3TxFaultread-onlycurrent40G1Q4S QSFP Plus 3 Port Transceiver Failure. 0:Normal 1:Failure
1.3.6.1.4.1.4756.20.620.20.1.28Columnf40G1Q4SQSFPP4TxFaultread-onlycurrent40G1Q4S QSFP Plus 4 Port Transceiver Failure. 0:Normal 1:Failure
1.3.6.1.4.1.4756.20.620.20.1.29Columnf40G1Q4SSFPP1TxFaultread-onlycurrent40G1Q4S SFP Plus 1 Port Transceiver Failure. 0:Normal 1:Failure
1.3.6.1.4.1.4756.20.620.20.1.30Columnf40G1Q4SSFPP2TxFaultread-onlycurrent40G1Q4S SFP Plus 2 Port Transceiver Failure. 0:Normal 1:Failure
1.3.6.1.4.1.4756.20.620.20.1.31Columnf40G1Q4SSFPP3TxFaultread-onlycurrent40G1Q4S SFP Plus 3 Port Transceiver Failure. 0:Normal 1:Failure
1.3.6.1.4.1.4756.20.620.20.1.32Columnf40G1Q4SSFPP4TxFaultread-onlycurrent40G1Q4S SFP Plus 4 Port Transceiver Failure. 0:Normal 1:Failure
1.3.6.1.4.1.4756.20.620.20.1.33Columnf40G1Q4SQSFPP1LOSread-onlycurrent40G1Q4S QSFP Plus 1 Port Loss of Signal. 0:Yes 1:No
1.3.6.1.4.1.4756.20.620.20.1.34Columnf40G1Q4SQSFPP2LOSread-onlycurrent40G1Q4S QSFP Plus 2 Port Loss of Signal. yes(0), no(1)
1.3.6.1.4.1.4756.20.620.20.1.35Columnf40G1Q4SQSFPP3LOSread-onlycurrent40G1Q4S QSFP Plus 3 Port Loss of Signal. 0:Yes 1:No
1.3.6.1.4.1.4756.20.620.20.1.36Columnf40G1Q4SQSFPP4LOSread-onlycurrent40G1Q4S QSFP Plus 4 Port Loss of Signal. 0:Yes 1:No
1.3.6.1.4.1.4756.20.620.20.1.37Columnf40G1Q4SSFPP1LOSread-onlycurrent40G1Q4S SFP Plus 1 Port Loss of Signal. 0:Yes 1:No
1.3.6.1.4.1.4756.20.620.20.1.38Columnf40G1Q4SSFPP2LOSread-onlycurrent40G1Q4S SFP Plus 2 Port Loss of Signal. 0:Yes 1:No
1.3.6.1.4.1.4756.20.620.20.1.39Columnf40G1Q4SSFPP3LOSread-onlycurrent40G1Q4S SFP Plus 3 Port Loss of Signal. 0:Yes 1:No
1.3.6.1.4.1.4756.20.620.20.1.40Columnf40G1Q4SSFPP4LOSread-onlycurrent40G1Q4S SFP Plus 4 Port Loss of Signal. 0:Yes 1:No
1.3.6.1.4.1.4756.20.620.20.1.41Columnf40G1Q4SQSFPP1CDRLockread-onlycurrent40G1Q4S QSFP Plus 1 Port Cable Distribution Rack. 0:Not Locked 1:Locked
1.3.6.1.4.1.4756.20.620.20.1.42Columnf40G1Q4SQSFPP2CDRLockread-onlycurrent40G1Q4S QSFP Plus 2 Port Cable Distribution Rack. 0:Not Locked 1:Locked
1.3.6.1.4.1.4756.20.620.20.1.43Columnf40G1Q4SQSFPP3CDRLockread-onlycurrent40G1Q4S QSFP Plus 3 Port Cable Distribution Rack. 0:Not Locked 1:Locked
1.3.6.1.4.1.4756.20.620.20.1.44Columnf40G1Q4SQSFPP4CDRLockread-onlycurrent40G1Q4S QSFP Plus 4 Port Cable Distribution Rack. 0:Not Locked 1:Locked
1.3.6.1.4.1.4756.20.620.20.1.45Columnf40G1Q4SSFPP1CDRLockread-onlycurrent40G1Q4S SFP Plus 1 Port Cable Distribution Rack. 0:Not Locked 1:Locked
1.3.6.1.4.1.4756.20.620.20.1.46Columnf40G1Q4SSFPP2CDRLockread-onlycurrent40G1Q4S SFP Plus 2 Port Cable Distribution Rack. 0:Not Locked 1:Locked
1.3.6.1.4.1.4756.20.620.20.1.47Columnf40G1Q4SSFPP3CDRLockread-onlycurrent40G1Q4S SFP Plus 3 Port Cable Distribution Rack. 0:Not Locked 1:Locked
1.3.6.1.4.1.4756.20.620.20.1.48Columnf40G1Q4SSFPP4CDRLockread-onlycurrent40G1Q4S SFP Plus 4 Port Cable Distribution Rack. 0:Not Locked 1:Locked
1.3.6.1.4.1.4756.20.620.20.1.49Columnf40G1Q4SPortActiveread-writecurrent40G1Q4S Port Active feature. 0:Disable 1:Enable
1.3.6.1.4.1.4756.20.620.20.1.50Columnf40G1Q4SDataRateStatusread-onlycurrent40G1Q4S Port Date Rate status.
1.3.6.1.4.1.4756.20.620.20.1.51Columnf40G1Q4SDataRateread-writecurrent40G1Q4S Port Date Rate setting. 0:Ethernet 10GE 1:SONET/SDH OC192/STM64 2:Fiber Ch 16G 3:Fiber Ch 10G 4:Fiber Ch 8G 5:CPRI x16
1.3.6.1.4.1.4756.20.620.20.1.52Columnf40G1Q4SSFPLBTread-writecurrent40G1Q4S SFP Plus Loopback Test Function. 0:Disable 1:Enable
1.3.6.1.4.1.4756.20.620.20.1.53Columnf40G1Q4SQSFPLBTread-writecurrent40G1Q4S QSFP Plus Loopback Test Function. 0:Disable 1:Enable
1.3.6.1.4.1.4756.20.620.20.1.54Columnf40G1Q4SSFPQSFPLBTread-writecurrent40G1Q4S SFP Plus and QSFP Plus Loopback Test Function. 0:Disable 1:Enable
1.3.6.1.4.1.4756.20.620.20.1.55Columnf40G1Q4SQSFPPLFPread-writecurrent40G1Q4S QSFP Plus Link Fault Pass-Throuth Function. 0:Disable 1:Enable
1.3.6.1.4.1.4756.20.620.20.1.56Columnf40G1Q4SSFPP1LFPread-writecurrent40G1Q4S SFP Plus 1 Link Fault Pass-Throuth Function. 0:Disable 1:Enable
1.3.6.1.4.1.4756.20.620.20.1.57Columnf40G1Q4SSFPP2LFPread-writecurrent40G1Q4S SFP Plus 2 Link Fault Pass-Throuth Function. 0:Disable 1:Enable
1.3.6.1.4.1.4756.20.620.20.1.58Columnf40G1Q4SSFPP3LFPread-writecurrent40G1Q4S SFP Plus 3 Link Fault Pass-Throuth Function. 0:Disable 1:Enable
1.3.6.1.4.1.4756.20.620.20.1.59Columnf40G1Q4SSFPP4LFPread-writecurrent40G1Q4S SFP Plus 4 Link Fault Pass-Throuth Function. 0:Disable 1:Enable
1.3.6.1.4.1.4756.20.620.20.1.60Columnf40G1Q4SQSFPP1LinkAlarmread-writecurrent40G1Q4S QSFP Plus 1 Link Alarm function. 0:Disable 1:Enable
1.3.6.1.4.1.4756.20.620.20.1.61Columnf40G1Q4SQSFPP2LinkAlarmread-writecurrent40G1Q4S QSFP Plus 2 Link Alarm function. 0:Disable 1:Enable
1.3.6.1.4.1.4756.20.620.20.1.62Columnf40G1Q4SQSFPP3LinkAlarmread-writecurrent40G1Q4S QSFP Plus 3 Link Alarm function. 0:Disable 1:Enable
1.3.6.1.4.1.4756.20.620.20.1.63Columnf40G1Q4SQSFPP4LinkAlarmread-writecurrent40G1Q4S QSFP Plus 4 Link Alarm function. 0:Disable 1:Enable
1.3.6.1.4.1.4756.20.620.20.1.64Columnf40G1Q4SSFPP1LinkAlarmread-writecurrent40G1Q4S SFP Plus 1 Link Alarm function. 0:Disable 1:Enable
1.3.6.1.4.1.4756.20.620.20.1.65Columnf40G1Q4SSFPP2LinkAlarmread-writecurrent40G1Q4S SFP Plus 2 Link Alarm function. 0:Disable 1:Enable
1.3.6.1.4.1.4756.20.620.20.1.66Columnf40G1Q4SSFPP3LinkAlarmread-writecurrent40G1Q4S SFP Plus 3 Link Alarm function. 0:Disable 1:Enable
1.3.6.1.4.1.4756.20.620.20.1.67Columnf40G1Q4SSFPP4LinkAlarmread-writecurrent40G1Q4S SFP Plus 4 Link Alarm function. 0:Disable 1:Enable
1.3.6.1.4.1.4756.20.620.20.1.68Columnf40G1Q4SQSFPP1LockAlarmread-writecurrent40G1Q4S QSFP Plus 1 Lock Alarm function. 0:Disable 1:Enable
1.3.6.1.4.1.4756.20.620.20.1.69Columnf40G1Q4SQSFPP2LockAlarmread-writecurrent40G1Q4S QSFP Plus 1 Lock Alarm function. 0:Disable 1:Enable
1.3.6.1.4.1.4756.20.620.20.1.70Columnf40G1Q4SQSFPP3LockAlarmread-writecurrent40G1Q4S QSFP Plus 3 Lock Alarm function. 0:Disable 1:Enable
1.3.6.1.4.1.4756.20.620.20.1.71Columnf40G1Q4SQSFPP4LockAlarmread-writecurrent40G1Q4S QSFP Plus 4 Lock Alarm function. 0:Disable 1:Enable
1.3.6.1.4.1.4756.20.620.20.1.72Columnf40G1Q4SSFPP1LockAlarmread-writecurrent40G1Q4S SFP Plus 1 Lock Alarm function. 0:Disable 1:Enable
1.3.6.1.4.1.4756.20.620.20.1.73Columnf40G1Q4SSFPP2LockAlarmread-writecurrent40G1Q4S SFP Plus 2 Lock Alarm function. 0:Disable 1:Enable
1.3.6.1.4.1.4756.20.620.20.1.74Columnf40G1Q4SSFPP3LockAlarmread-writecurrent40G1Q4S SFP Plus 3 Lock Alarm function. 0:Disable 1:Enable
1.3.6.1.4.1.4756.20.620.20.1.75Columnf40G1Q4SSFPP4LockAlarmread-writecurrent40G1Q4S SFP Plus 4 Lock Alarm function. 0:Disable 1:Enable
1.3.6.1.4.1.4756.20.620.20.1.76Columnf40G1Q4SQSFPP1TxFAlarmread-writecurrent40G1Q4S QSFP Plus 1 Transceiver Fault Alarm function. 0:Disable 1:Enable
1.3.6.1.4.1.4756.20.620.20.1.77Columnf40G1Q4SQSFPP2TxFAlarmread-writecurrent40G1Q4S QSFP Plus 2 Transceiver Fault Alarm function. 0:Disable 1:Enable
1.3.6.1.4.1.4756.20.620.20.1.78Columnf40G1Q4SQSFPP3TxFAlarmread-writecurrent40G1Q4S QSFP Plus 3 Transceiver Fault Alarm function. 0:Disable 1:Enable
1.3.6.1.4.1.4756.20.620.20.1.79Columnf40G1Q4SQSFPP4TxFAlarmread-writecurrent40G1Q4S QSFP Plus 4 Transceiver Fault Alarm function. 0:Disable 1:Enable
1.3.6.1.4.1.4756.20.620.20.1.80Columnf40G1Q4SSFPP1TxFAlarmread-writecurrent40G1Q4S SFP Plus 1 Transceiver Fault Alarm function. 0:Disable 1:Enable
1.3.6.1.4.1.4756.20.620.20.1.81Columnf40G1Q4SSFPP2TxFAlarmread-writecurrent40G1Q4S SFP Plus 2 Transceiver Fault Alarm function. 0:Disable 1:Enable
1.3.6.1.4.1.4756.20.620.20.1.82Columnf40G1Q4SSFPP3TxFAlarmread-writecurrent40G1Q4S SFP Plus 3 Transceiver Fault Alarm function. 0:Disable 1:Enable
1.3.6.1.4.1.4756.20.620.20.1.83Columnf40G1Q4SSFPP4TxFAlarmread-writecurrent40G1Q4S SFP Plus 4 Transceiver Fault Alarm function. 0:Disable 1:Enable
1.3.6.1.4.1.4756.20.620.20.1.84Columnf40G1Q4SQSFPPVendorNameread-onlycurrent40G1Q4S QSFP Plus Vendor Name.
1.3.6.1.4.1.4756.20.620.20.1.85Columnf40G1Q4SQSFPPPartNoread-onlycurrent40G1Q4S QSFP Plus Part Number.
1.3.6.1.4.1.4756.20.620.20.1.86Columnf40G1Q4SQSFPPVendorSNread-onlycurrent40G1Q4S QSFP Plus Vendor Serial Number.
1.3.6.1.4.1.4756.20.620.20.1.87Columnf40G1Q4SQSFPPOpticalTyperead-onlycurrent40G1Q4S QSFP Plus Optical Type. 0: Multi 1: Single 2: UnKnown
1.3.6.1.4.1.4756.20.620.20.1.88Columnf40G1Q4SQSFPPWaveLength1read-onlycurrent40G1Q4S QSFP Plus Wave Length 1.
1.3.6.1.4.1.4756.20.620.20.1.89Columnf40G1Q4SQSFPPWaveLength2read-onlycurrent40G1Q4S QSFP Plus Wave Length 2.
1.3.6.1.4.1.4756.20.620.20.1.90Columnf40G1Q4SQSFPPOM3LinkLengthread-onlycurrent40G1Q4S QSFP Plus OM3 Link Length.
1.3.6.1.4.1.4756.20.620.20.1.91Columnf40G1Q4SQSFPPTempread-onlycurrent40G1Q4S QSFP Plus Temperature.
1.3.6.1.4.1.4756.20.620.20.1.92Columnf40G1Q4SQSFPPSupplyVolread-onlycurrent40G1Q4S QSFP Plus Supply Voltage.
1.3.6.1.4.1.4756.20.620.20.1.93Columnf40G1Q4SQSFPP1TxPowerread-onlycurrent40G1Q4S QSFP Plus 1 Transceiver Power.
1.3.6.1.4.1.4756.20.620.20.1.94Columnf40G1Q4SQSFPP1RxPowerread-onlycurrent40G1Q4S QSFP Plus 1 Receiver Power.
1.3.6.1.4.1.4756.20.620.20.1.95Columnf40G1Q4SQSFPP1TxLaserBiasread-onlycurrent40G1Q4S QSFP Plus 1 Transceiver Laser BIAS.
1.3.6.1.4.1.4756.20.620.20.1.96Columnf40G1Q4SQSFPP2TxPowerread-onlycurrent40G1Q4S QSFP Plus 2 Transceiver Power.
1.3.6.1.4.1.4756.20.620.20.1.97Columnf40G1Q4SQSFPP2RxPowerread-onlycurrent40G1Q4S QSFP Plus 2 Receiver Power.
1.3.6.1.4.1.4756.20.620.20.1.98Columnf40G1Q4SQSFPP2TxLaserBiasread-onlycurrent40G1Q4S QSFP Plus 2 Transceiver Laser BIAS.
1.3.6.1.4.1.4756.20.620.20.1.99Columnf40G1Q4SQSFPP3TxPowerread-onlycurrent40G1Q4S QSFP Plus 3 Transceiver Power.
1.3.6.1.4.1.4756.20.620.20.1.100Columnf40G1Q4SQSFPP3RxPowerread-onlycurrent40G1Q4S QSFP Plus 3 Receiver Power.
1.3.6.1.4.1.4756.20.620.20.1.101Columnf40G1Q4SQSFPP3TxLaserBiasread-onlycurrent40G1Q4S QSFP Plus 3 Transceiver Laser BIAS.
1.3.6.1.4.1.4756.20.620.20.1.102Columnf40G1Q4SQSFPP4TxPowerread-onlycurrent40G1Q4S QSFP Plus 4 Transceiver Power.
1.3.6.1.4.1.4756.20.620.20.1.103Columnf40G1Q4SQSFPP4RxPowerread-onlycurrent40G1Q4S QSFP Plus 4 Receiver Power.
1.3.6.1.4.1.4756.20.620.20.1.104Columnf40G1Q4SQSFPP4TxLaserBiasread-onlycurrent40G1Q4S QSFP Plus 4 Transceiver Laser BIAS.
1.3.6.1.4.1.4756.20.620.20.1.105Columnf40G1Q4SSFPP1VendorNameread-onlycurrent40G1Q4S SFP Plus 1 Vendor Name.
1.3.6.1.4.1.4756.20.620.20.1.106Columnf40G1Q4SSFPP1PartNoread-onlycurrent40G1Q4S SFP Plus 1 Part Number.
1.3.6.1.4.1.4756.20.620.20.1.107Columnf40G1Q4SSFPP1VendorSNread-onlycurrent40G1Q4S SFP Plus 1 Vendor Serial Number.
1.3.6.1.4.1.4756.20.620.20.1.108Columnf40G1Q4SSFPP1OpticalTyperead-onlycurrent40G1Q4S SFP Plus 1 Optical Type: 0: Multi 1: Single 2: UnKnown
1.3.6.1.4.1.4756.20.620.20.1.109Columnf40G1Q4SSFPP1WaveLengthread-onlycurrent40G1Q4S SFP Plus 1 Wave Length.
1.3.6.1.4.1.4756.20.620.20.1.110Columnf40G1Q4SSFPP1WaveLength2read-onlycurrent40G1Q4S SFP Plus 1 Wave Length2.
1.3.6.1.4.1.4756.20.620.20.1.111Columnf40G1Q4SSFPP1LinkLengthread-onlycurrent40G1Q4S SFP Plus 1 Link Length.
1.3.6.1.4.1.4756.20.620.20.1.112Columnf40G1Q4SSFPP1TxPowerread-onlycurrent40G1Q4S SFP Plus 1 Transceiver Power.
1.3.6.1.4.1.4756.20.620.20.1.113Columnf40G1Q4SSFPP1RxPowerread-onlycurrent40G1Q4S SFP Plus 1 Receiver Power.
1.3.6.1.4.1.4756.20.620.20.1.114Columnf40G1Q4SSFPP1RxSensread-onlycurrent40G1Q4S SFP Plus 1 Receiver Sensitivity.
1.3.6.1.4.1.4756.20.620.20.1.115Columnf40G1Q4SSFPP1RxPwrMarginread-onlycurrent40G1Q4S SFP Plus 1 Receiver Power Margin.
1.3.6.1.4.1.4756.20.620.20.1.116Columnf40G1Q4SSFPP1Tempread-onlycurrent40G1Q4S SFP Plus 1 Temperature.
1.3.6.1.4.1.4756.20.620.20.1.117Columnf40G1Q4SSFPP1SupplyVolread-onlycurrent40G1Q4S SFP Plus 1 Supply Voltage.
1.3.6.1.4.1.4756.20.620.20.1.118Columnf40G1Q4SSFPP1TxLaserBiasread-onlycurrent40G1Q4S SFP Plus 1 Transceiver Laser BIAS.
1.3.6.1.4.1.4756.20.620.20.1.119Columnf40G1Q4SSFPP2VendorNameread-onlycurrent40G1Q4S SFP Plus 2 Vendor Name.
1.3.6.1.4.1.4756.20.620.20.1.120Columnf40G1Q4SSFPP2PartNoread-onlycurrent40G1Q4S SFP Plus 2 Part Number.
1.3.6.1.4.1.4756.20.620.20.1.121Columnf40G1Q4SSFPP2VendorSNread-onlycurrent40G1Q4S SFP Plus 2 Vendor Serial Number.
1.3.6.1.4.1.4756.20.620.20.1.122Columnf40G1Q4SSFPP2OpticalTyperead-onlycurrent40G1Q4S SFP Plus 2 Optical Type: 0: Multi 1: Single 2: UnKnown
1.3.6.1.4.1.4756.20.620.20.1.123Columnf40G1Q4SSFPP2WaveLengthread-onlycurrent40G1Q4S SFP Plus 2 Wave Length.
1.3.6.1.4.1.4756.20.620.20.1.124Columnf40G1Q4SSFPP2WaveLength2read-onlycurrent40G1Q4S SFP Plus 2 Wave Length2.
1.3.6.1.4.1.4756.20.620.20.1.125Columnf40G1Q4SSFPP2LinkLengthread-onlycurrent40G1Q4S SFP Plus 2 Link Length.
1.3.6.1.4.1.4756.20.620.20.1.126Columnf40G1Q4SSFPP2TxPowerread-onlycurrent40G1Q4S SFP Plus 2 Transceiver Power.
1.3.6.1.4.1.4756.20.620.20.1.127Columnf40G1Q4SSFPP2RxPowerread-onlycurrent40G1Q4S SFP Plus 2 Receiver Power.
1.3.6.1.4.1.4756.20.620.20.1.128Columnf40G1Q4SSFPP2RxSensread-onlycurrent40G1Q4S SFP Plus 2 Receiver Sensitivity.
1.3.6.1.4.1.4756.20.620.20.1.129Columnf40G1Q4SSFPP2RxPwrMarginread-onlycurrent40G1Q4S SFP Plus 2 Receiver Power Margin.
1.3.6.1.4.1.4756.20.620.20.1.130Columnf40G1Q4SSFPP2Tempread-onlycurrent40G1Q4S SFP Plus 2 Temperature.
1.3.6.1.4.1.4756.20.620.20.1.131Columnf40G1Q4SSFPP2SupplyVolread-onlycurrent40G1Q4S SFP Plus 2 Supply Voltage.
1.3.6.1.4.1.4756.20.620.20.1.132Columnf40G1Q4SSFPP2TxLaserBiasread-onlycurrent40G1Q4S SFP Plus 2 Transceiver Laser BIAS.
1.3.6.1.4.1.4756.20.620.20.1.133Columnf40G1Q4SSFPP3VendorNameread-onlycurrent40G1Q4S SFP Plus 3 Vendor Name.
1.3.6.1.4.1.4756.20.620.20.1.134Columnf40G1Q4SSFPP3PartNoread-onlycurrent40G1Q4S SFP Plus 3 Part Number.
1.3.6.1.4.1.4756.20.620.20.1.135Columnf40G1Q4SSFPP3VendorSNread-onlycurrent40G1Q4S SFP Plus 3 Vendor Serial Number.
1.3.6.1.4.1.4756.20.620.20.1.136Columnf40G1Q4SSFPP3OpticalTyperead-onlycurrent40G1Q4S SFP Plus 3 Optical Type: 0: Multi 1: Single 2: UnKnown
1.3.6.1.4.1.4756.20.620.20.1.137Columnf40G1Q4SSFPP3WaveLengthread-onlycurrent40G1Q4S SFP Plus 3 Wave Length.
1.3.6.1.4.1.4756.20.620.20.1.138Columnf40G1Q4SSFPP3WaveLength2read-onlycurrent40G1Q4S SFP Plus 3 Wave Length2.
1.3.6.1.4.1.4756.20.620.20.1.139Columnf40G1Q4SSFPP3LinkLengthread-onlycurrent40G1Q4S SFP Plus 3 Link Length.
1.3.6.1.4.1.4756.20.620.20.1.140Columnf40G1Q4SSFPP3TxPowerread-onlycurrent40G1Q4S SFP Plus 3 Transceiver Power.
1.3.6.1.4.1.4756.20.620.20.1.141Columnf40G1Q4SSFPP3RxPowerread-onlycurrent40G1Q4S SFP Plus 3 Receiver Power.
1.3.6.1.4.1.4756.20.620.20.1.142Columnf40G1Q4SSFPP3RxSensread-onlycurrent40G1Q4S SFP Plus 3 Receiver Sensitivity.
1.3.6.1.4.1.4756.20.620.20.1.143Columnf40G1Q4SSFPP3RxPwrMarginread-onlycurrent40G1Q4S SFP Plus 3 Receiver Power Margin.
1.3.6.1.4.1.4756.20.620.20.1.144Columnf40G1Q4SSFPP3Tempread-onlycurrent40G1Q4S SFP Plus 3 Temperature.
1.3.6.1.4.1.4756.20.620.20.1.145Columnf40G1Q4SSFPP3SupplyVolread-onlycurrent40G1Q4S SFP Plus 3 Supply Voltage.
1.3.6.1.4.1.4756.20.620.20.1.146Columnf40G1Q4SSFPP3TxLaserBiasread-onlycurrent40G1Q4S SFP Plus 3 Transceiver Laser BIAS.
1.3.6.1.4.1.4756.20.620.20.1.147Columnf40G1Q4SSFPP4VendorNameread-onlycurrent40G1Q4S SFP Plus 4 Vendor Name.
1.3.6.1.4.1.4756.20.620.20.1.148Columnf40G1Q4SSFPP4PartNoread-onlycurrent40G1Q4S SFP Plus 4 Part Number.
1.3.6.1.4.1.4756.20.620.20.1.149Columnf40G1Q4SSFPP4VendorSNread-onlycurrent40G1Q4S SFP Plus 4 Vendor Serial Number.
1.3.6.1.4.1.4756.20.620.20.1.150Columnf40G1Q4SSFPP4OpticalTyperead-onlycurrent40G1Q4S SFP Plus 4 Optical Type: 0: Multi 1: Single 2: UnKnown
1.3.6.1.4.1.4756.20.620.20.1.151Columnf40G1Q4SSFPP4WaveLengthread-onlycurrent40G1Q4S SFP Plus 4 Wave Length.
1.3.6.1.4.1.4756.20.620.20.1.152Columnf40G1Q4SSFPP4WaveLength2read-onlycurrent40G1Q4S SFP Plus 4 Wave Length2.
1.3.6.1.4.1.4756.20.620.20.1.153Columnf40G1Q4SSFPP4LinkLengthread-onlycurrent40G1Q4S SFP Plus 4 Link Length.
1.3.6.1.4.1.4756.20.620.20.1.154Columnf40G1Q4SSFPP4TxPowerread-onlycurrent40G1Q4S SFP Plus 4 Transceiver Power.
1.3.6.1.4.1.4756.20.620.20.1.155Columnf40G1Q4SSFPP4RxPowerread-onlycurrent40G1Q4S SFP Plus 4 Receiver Power.
1.3.6.1.4.1.4756.20.620.20.1.156Columnf40G1Q4SSFPP4RxSensread-onlycurrent40G1Q4S SFP Plus 4 Receiver Sensitivity.
1.3.6.1.4.1.4756.20.620.20.1.157Columnf40G1Q4SSFPP4RxPwrMarginread-onlycurrent40G1Q4S SFP Plus 4 Receiver Power Margin.
1.3.6.1.4.1.4756.20.620.20.1.158Columnf40G1Q4SSFPP4Tempread-onlycurrent40G1Q4S SFP Plus 4 Temperature.
1.3.6.1.4.1.4756.20.620.20.1.159Columnf40G1Q4SSFPP4SupplyVolread-onlycurrent40G1Q4S SFP Plus 4 Supply Voltage.
1.3.6.1.4.1.4756.20.620.20.1.160Columnf40G1Q4SSFPP4TxLaserBiasread-onlycurrent40G1Q4S SFP Plus 4 Transceiver Laser BIAS.
1.3.6.1.4.1.4756.20.630Nodef10GCCards
1.3.6.1.4.1.4756.20.630.20Tablef10GCTablenot-accessiblecurrentA list of local FRM220-10GC card entries. The number of entries is f10GC-No-L.
1.3.6.1.4.1.4756.20.630.20.1Rowf10GCEntrynot-accessiblecurrentAn entry containing management information applicable to a particular local FRM220-10GC series card.
1.3.6.1.4.1.4756.20.630.20.1.1Columnf10GCChassisIndexread-onlycurrentA unique value for each card. It starts from 0 to 9 contiguously.
1.3.6.1.4.1.4756.20.630.20.1.2Columnf10GCSlotIndexread-onlycurrentA unique value for each card. It starts from 1 to 20 contiguously.
1.3.6.1.4.1.4756.20.630.20.1.3Columnf10GCCardHWVerread-onlycurrent10GC card hardware version x.xxx
1.3.6.1.4.1.4756.20.630.20.1.4Columnf10GCCardFWVerread-onlycurrent10GC card firmware version x.xxx
1.3.6.1.4.1.4756.20.630.20.1.5Columnf10GCCardCPLDVerread-onlycurrent10GC card CPLD version x.xxx
1.3.6.1.4.1.4756.20.630.20.1.6Columnf10GCCardFPGAVerread-onlycurrent10GC card FPGA version x.xxx
1.3.6.1.4.1.4756.20.630.20.1.7Columnf10GCPortResetread-writecurrent10GC card system status: 0:Off 1:Trigger
1.3.6.1.4.1.4756.20.630.20.1.8Columnf10GCSetToDefaultread-writecurrent10GC card port set to default: 0:Off 1:Trigger
1.3.6.1.4.1.4756.20.630.20.1.9Columnf10GCFxLinkread-onlycurrent10GC card fiber link status.
1.3.6.1.4.1.4756.20.630.20.1.10Columnf10GCFxSFPread-onlycurrent10GC card fiber socket status.
1.3.6.1.4.1.4756.20.630.20.1.11Columnf10GCFxFiberTxFaultread-onlycurrent10GC card fiber Tx Fault status.
1.3.6.1.4.1.4756.20.630.20.1.12Columnf10GCFxDDStatusread-onlycurrent10GC card fiber Digital Diagnostic status.
1.3.6.1.4.1.4756.20.630.20.1.13Columnf10GCFxPortActiveread-writecurrent10GC card fiber port active: 0:Disable 1:Enable
1.3.6.1.4.1.4756.20.630.20.1.14Columnf10GCFxLBTread-writecurrent10GC card fiber port Loopback Test function: 0:Disable 1:Enable NOTE: The loopback function of 10GBase-R and 10GBase-T CAN NOT be activated at the same time.
1.3.6.1.4.1.4756.20.630.20.1.15Columnf10GCFxFFAread-writecurrent10GC card fiber fault alert: 0:Disable 1:Enable
1.3.6.1.4.1.4756.20.630.20.1.16Columnf10GCFxALSread-writecurrent10GC card fiber Automatically Laser Shutdown: 0:Disable 1:Enable
1.3.6.1.4.1.4756.20.630.20.1.17Columnf10GCFxLFPread-writecurrent10GC card fiber Link Fault Pass-Through: 0:Disable 1:Enable
1.3.6.1.4.1.4756.20.630.20.1.18Columnf10GCUtpLinkread-onlycurrent10GC card UTP Link status.
1.3.6.1.4.1.4756.20.630.20.1.19Columnf10GCUtpSpeedread-onlycurrent10GC card UTP link speed status.
1.3.6.1.4.1.4756.20.630.20.1.20Columnf10GCUtpPortActiveread-writecurrent10GC card UTP Port Active: 0:Disable 1:Enable
1.3.6.1.4.1.4756.20.630.20.1.21Columnf10GCUtpLBTread-writecurrent10GC card UTP Loopback Test Function: 0:Disable 1:Enable NOTE: The loopback function of 10GBase-R and 10GBase-T CAN NOT be activated at the same time.
1.3.6.1.4.1.4756.20.630.20.1.22Columnf10GCUtpAutoCfgread-writecurrent10GC card UTP Auto-Negotiation setting: 0:Force 1:Auto
1.3.6.1.4.1.4756.20.630.20.1.23Columnf10GCUtpSpeedCfgread-writecurrent10GC card UTP Speed setting: 0:10GBase-T 1:1000Base-T 2:100Base-TX 3:
1.3.6.1.4.1.4756.20.630.20.1.24Columnf10GCUtpSRMread-writecurrent10GC card UTP Short Reach Mode (< 30m) setting: 0:Disable 1:Enable
1.3.6.1.4.1.4756.20.630.20.1.25Columnf10GCDeviceTempread-onlycurrent10GC card device temperature status.
1.3.6.1.4.1.4756.20.630.20.1.26Columnf10GCDeviceCurrTempread-onlycurrent10GC card device current temperature.
1.3.6.1.4.1.4756.20.630.20.1.27Columnf10GCDeviceActiveread-writecurrent10GC card Fiber and UTP port active: 0:Disable 1:Enable
1.3.6.1.4.1.4756.20.630.20.1.28Columnf10GCDeviceTempProtread-writecurrent10GC card Thermal Protection setting: 0:80 degree C 1:90 degree C 2:100 degree C 3:110 degree C
1.3.6.1.4.1.4756.20.630.20.1.29Columnf10GCDeviceTempAlarmread-writecurrent10GC card Temperature Alarm setting: 0:Disable 1:Enable
1.3.6.1.4.1.4756.20.630.20.1.30Columnf10GCDeviceFTFAlarmread-writecurrent10GC card Fiber Tx Fault Alarm setting: 0:Disable 1:Enable
1.3.6.1.4.1.4756.20.630.20.1.31Columnf10GCDeviceEEEread-writecurrent10GC card Energy Efficient Ethernet setting: 0:Disable 1:Enable
1.3.6.1.4.1.4756.20.630.20.1.32Columnf10GCDSSFPAread-writecurrent10GC card DIP Switch Status Front Panel Active setting: 0:Disable 1:Enable
1.3.6.1.4.1.4756.20.630.20.1.33Columnf10GCDSSFXLFPread-onlycurrent10GC card DIP Switch Fiber Link Fault Pass-Through status.
1.3.6.1.4.1.4756.20.630.20.1.34Columnf10GCDSSUTPSRMread-onlycurrent10GC card DIP Switch UTP Short Reach Mode (< 30m) status.
1.3.6.1.4.1.4756.20.630.20.1.35Columnf10GCDSSFXLBTread-onlycurrent10GC card DIP Switch Fiber Loopback Testing Function status.
1.3.6.1.4.1.4756.20.630.20.1.36Columnf10GCDSSUTPLBTread-onlycurrent10GC card DIP Switch UTP Loopback Testing Function status.
1.3.6.1.4.1.4756.20.630.20.1.37Columnf10GCDSSBERTread-onlycurrent10GC card DIP Switch BERT function status.
1.3.6.1.4.1.4756.20.630.20.1.38Columnf10GCDSSEEEread-onlycurrent10GC card DIP Switch Energy Efficient Ethernet function status.
1.3.6.1.4.1.4756.20.630.20.1.39Columnf10GCSFPPVenderNameread-onlycurrent10GC card SFP Plus Vender Name.
1.3.6.1.4.1.4756.20.630.20.1.40Columnf10GCSFPPPartNoread-onlycurrent10GC card SFP Plus Part Number.
1.3.6.1.4.1.4756.20.630.20.1.41Columnf10GCSFPPFiberTyperead-onlycurrent10GC card SFP Plus Fiber Type: 0:Multi 1:Single 2:Unknown
1.3.6.1.4.1.4756.20.630.20.1.42Columnf10GCSFPPWaveLength1read-onlycurrent10GC card SFP Plus Wave Length 1.
1.3.6.1.4.1.4756.20.630.20.1.43Columnf10GCSFPPWaveLength2read-onlycurrent10GC card SFP Plus Wave Length 2.
1.3.6.1.4.1.4756.20.630.20.1.44Columnf10GCSFPPLinkLengthread-onlycurrent10GC card SFP Plus Link Length.
1.3.6.1.4.1.4756.20.630.20.1.45Columnf10GCSFPPTxPowerread-onlycurrent10GC card SFP Plus Transmit Power.
1.3.6.1.4.1.4756.20.630.20.1.46Columnf10GCSFPPRxPowerread-onlycurrent10GC card SFP Plus Receive Power.
1.3.6.1.4.1.4756.20.630.20.1.47Columnf10GCSFPPRxSensread-onlycurrent10GC card SFP Plus Receive Sensitivity.
1.3.6.1.4.1.4756.20.630.20.1.48Columnf10GCSFPPRxPwrMarginread-onlycurrent10GC card SFP Plus Receive Power Margin.
1.3.6.1.4.1.4756.20.630.20.1.49Columnf10GCSFPPTemperatureread-onlycurrent10GC card SFP Plus Temperature.
1.3.6.1.4.1.4756.20.630.20.1.50Columnf10GCSFPPSupplyVoltageread-onlycurrent10GC card SFP Plus Supply Voltage.
1.3.6.1.4.1.4756.20.630.20.1.51Columnf10GCSFPPTxLaserBiasread-onlycurrent10GC card SFP Plus Supply Voltage.
1.3.6.1.4.1.4756.20.640NodefOADMCards
1.3.6.1.4.1.4756.20.640.20TablefOADMTablenot-accessiblecurrentA list of local FRM220-OADM Serial cards entries. The number of entries is fOADM-No-L.
1.3.6.1.4.1.4756.20.640.20.1RowfOADMEntrynot-accessiblecurrentAn entry containing management information applicable to a particular local FRM220-OADM series card.
1.3.6.1.4.1.4756.20.640.20.1.1ColumnfOADMChassisIndexread-onlycurrentA unique value for each card. It starts from 0 to 9 contiguously.
1.3.6.1.4.1.4756.20.640.20.1.2ColumnfOADMSlotIndexread-onlycurrentA unique value for each card. It starts from 1 to 20 contiguously.
1.3.6.1.4.1.4756.20.640.20.1.3ColumnfOADMCardHWVerread-onlycurrentFRM220-OADM Serial cards hardware version x.xxx
1.3.6.1.4.1.4756.20.640.20.1.4ColumnfOADMCardFWVerread-onlycurrentFRM220-OADM Serial cards firmware version x.xxx
1.3.6.1.4.1.4756.20.640.20.1.5ColumnfOADMCardCPLDVerread-onlycurrentFRM220-OADM Serial cards CPLD version x.xxx
1.3.6.1.4.1.4756.20.640.20.1.6ColumnfOADMCardFPGAVerread-onlycurrentFRM220-OADM Serial cards FPGA version x.xxx
1.3.6.1.4.1.4756.20.640.20.1.7ColumnfOADMCardModelread-onlycurrentThe OADM Serial cards Model type as below: 1:FRM220-OADM-61 2:FRM220-OADM-59 3:FRM220-OADM-57 4:FRM220-OADM-55 5:FRM220-OADM-53 6:FRM220-OADM-51 7:FRM220-OADM-…
1.3.6.1.4.1.4756.20.640.20.1.8ColumnfOADMCardEastWaveLength1read-onlycurrentFRM220-OADM Serial cards EAST Wave Length 1.
1.3.6.1.4.1.4756.20.640.20.1.9ColumnfOADMCardEastWaveLength2read-onlycurrentFRM220-OADM Serial cards EAST Wave Length 2.
1.3.6.1.4.1.4756.20.640.20.1.10ColumnfOADMCardWestWaveLength1read-onlycurrentFRM220-OADM Serial cards WEST Wave Length 1.
1.3.6.1.4.1.4756.20.640.20.1.11ColumnfOADMCardWestWaveLength2read-onlycurrentFRM220-OADM Serial cards WEST Wave Length 2.
1.3.6.1.4.1.4756.20.650NodefDWDMCards
1.3.6.1.4.1.4756.20.650.20TablefDWDMTablenot-accessiblecurrentA list of local FRM220-DWDM Serial cards entries. The number of entries is fDWDM-No-L.
1.3.6.1.4.1.4756.20.650.20.1RowfDWDMEntrynot-accessiblecurrentAn entry containing management information applicable to a particular local FRM220-DWDM series card.
1.3.6.1.4.1.4756.20.650.20.1.1ColumnfDWDMChassisIndexread-onlycurrentA unique value for each card. It starts from 0 to 9 contiguously.
1.3.6.1.4.1.4756.20.650.20.1.2ColumnfDWDMSlotIndexread-onlycurrentA unique value for each card. It starts from 1 to 20 contiguously.
1.3.6.1.4.1.4756.20.650.20.1.3ColumnfDWDMCardHWVerread-onlycurrentFRM220-DWDM Serial cards hardware version x.xxx
1.3.6.1.4.1.4756.20.650.20.1.4ColumnfDWDMCardFWVerread-onlycurrentFRM220-DWDM Serial cards firmware version x.xxx
1.3.6.1.4.1.4756.20.650.20.1.5ColumnfDWDMCardCPLDVerread-onlycurrentFRM220-DWDM Serial cards CPLD version x.xxx
1.3.6.1.4.1.4756.20.650.20.1.6ColumnfDWDMCardFPGAVerread-onlycurrentFRM220-DWDM Serial cards FPGA version x.xxx
1.3.6.1.4.1.4756.20.650.20.1.7ColumnfDWDMCardModelread-onlycurrentThe DWDM Serial cards Model type as below: 1:FRM220-DWMD401-C21-C24 1:FRM220-DWMD801-C21-C28
1.3.6.1.4.1.4756.20.650.20.1.8ColumnfDWDMCardC21WaveLengthread-onlycurrentFRM220-DWDM Serial cards C Band: Frequency: 192.1 THz Center Wave Length: 1560.61 nm
1.3.6.1.4.1.4756.20.650.20.1.9ColumnfDWDMCardC22WaveLengthread-onlycurrentFRM220-DWDM Serial cards C Band: Frequency: 192.2 THz Center Wave Length: 1559.79 nm
1.3.6.1.4.1.4756.20.650.20.1.10ColumnfDWDMCardC23WaveLengthread-onlycurrentFRM220-DWDM Serial cards C Band: Frequency: 192.3 THz Center Wave Length: 1558.98 nm
1.3.6.1.4.1.4756.20.650.20.1.11ColumnfDWDMCardC24WaveLengthread-onlycurrentFRM220-DWDM Serial cards C Band: Frequency: 192.4 THz Center Wave Length: 1558.17 nm
1.3.6.1.4.1.4756.20.650.20.1.12ColumnfDWDMCardC25WaveLengthread-onlycurrentFRM220-DWDM Serial cards C Band: Frequency: 192.5 THz Center Wave Length: 1557.36 nm
1.3.6.1.4.1.4756.20.650.20.1.13ColumnfDWDMCardC26WaveLengthread-onlycurrentFRM220-DWDM Serial cards C Band: Frequency: 192.6 THz Center Wave Length: 1556.55 nm
1.3.6.1.4.1.4756.20.650.20.1.14ColumnfDWDMCardC27WaveLengthread-onlycurrentFRM220-DWDM Serial cards C Band: Frequency: 192.7 THz Center Wave Length: 1555.75 nm
1.3.6.1.4.1.4756.20.650.20.1.15ColumnfDWDMCardC28WaveLengthread-onlycurrentFRM220-DWDM Serial cards C Band: Frequency: 192.8 THz Center Wave Length: 1554.94 nm
1.3.6.1.4.1.4756.20.660NodefCCFLocalCards
1.3.6.1.4.1.4756.20.660.20TablefCCFLocalTablenot-accessiblecurrentA list of local FRM220-CCF Serial cards entries. The number of entries is fCCF-No-L.
1.3.6.1.4.1.4756.20.660.20.1RowfCCFLocalEntrynot-accessiblecurrentAn entry containing management information applicable to a particular local FRM220-CCF series card.
1.3.6.1.4.1.4756.20.660.20.1.1ColumnfCCFChassisIndexLocalread-onlycurrentA unique value for each card. It starts from 0 to 9 contiguously.
1.3.6.1.4.1.4756.20.660.20.1.2ColumnfCCFSlotIndexLocalread-onlycurrentA unique value for each card. It starts from 1 to 20 contiguously.
1.3.6.1.4.1.4756.20.660.20.1.3ColumnfCCFCardHWVerLocalread-onlycurrentFRM220-CCF Serial cards hardware version x.xxx
1.3.6.1.4.1.4756.20.660.20.1.4ColumnfCCFCardFWVerLocalread-onlycurrentFRM220-CCF Serial cards firmware version x.xxx
1.3.6.1.4.1.4756.20.660.20.1.5ColumnfCCFCardCPLDVerLocalread-onlycurrentFRM220-CCF Serial cards CPLD version x.xxx
1.3.6.1.4.1.4756.20.660.20.1.6ColumnfCCFCardFPGAVerLocalread-onlycurrentFRM220-CCF Serial cards FPGA version x.xxx
1.3.6.1.4.1.4756.20.660.20.1.7ColumnfCCFCardModelLocalread-onlycurrentThe CCF Serial cards Model type as below: 0:FRM220-CCF20 1:FRM220-CCF40 8:IFC-CCF20-HP 9:IFC-CCF40-HP
1.3.6.1.4.1.4756.20.660.20.1.8ColumnfCCFPortResetLocalread-onlycurrentCCF card Port Reset feature: 0:Inactive 1:Active
1.3.6.1.4.1.4756.20.660.20.1.9ColumnfCCFSetToDefaultLocalread-onlycurrentCCF card Set To Default feature: 0:Inactive 1:Active
1.3.6.1.4.1.4756.20.660.20.1.10ColumnfCCFSFPExistLocalread-onlycurrentFRM220-CCF Serial cards SFP Exist Information.
1.3.6.1.4.1.4756.20.660.20.1.11ColumnfCCFSFPTypeLocalread-onlycurrentFRM220-CCF Serial cards SFP Type Information.
1.3.6.1.4.1.4756.20.660.20.1.12ColumnfCCFSFPTxFailureLocalread-onlycurrentFRM220-CCF Serial cards SFP Tx Failure Information.
1.3.6.1.4.1.4756.20.660.20.1.13ColumnfCCFSFPLinkLocalread-onlycurrentFRM220-CCF Serial cards SFP Link Information.
1.3.6.1.4.1.4756.20.660.20.1.14ColumnfCCFSFPSyncLocalread-onlycurrentFRM220-CCF Serial cards SFP Sync Information.
1.3.6.1.4.1.4756.20.660.20.1.15ColumnfCCFSFPLoopBackLocalread-onlycurrentFRM220-CCF Serial cards SFP Loopback Information.
1.3.6.1.4.1.4756.20.660.20.1.16ColumnfCCFSFPPortActiveLocalread-writecurrentFRM220-CCF Serial cards Port Active: 0:disable 1:enable
1.3.6.1.4.1.4756.20.660.20.1.17ColumnfCCFSFPALSLocalread-writecurrentFRM220-CCF Serial cards Automatic Laser Shutdown (ALS): 0:disable 1:enable
1.3.6.1.4.1.4756.20.660.20.1.18ColumnfCCFSFPTBLLocalread-writecurrentFRM220-CCF Serial cards Loopback Test Function: 0:Disable 1:LLB 2:RLB 3:RRLB
1.3.6.1.4.1.4756.20.660.20.1.19ColumnfCCFDeviceAlarmLocalread-onlycurrentFRM220-CCF Serial cards Alarm Status.
1.3.6.1.4.1.4756.20.660.20.1.20ColumnfCCFDeviceActiveLocalread-writecurrentFRM220-CCF Serial cards Device Active: 0:Disable 1:Enable
1.3.6.1.4.1.4756.20.660.20.1.21ColumnfCCFDeviceDebounceLocalread-writecurrentFRM220-CCF Serial cards Input Debounce: 0:Disable 1:Enable
1.3.6.1.4.1.4756.20.660.20.1.22ColumnfCCFDeviceLinkAlarmLocalread-writecurrentFRM220-CCF Serial cards Link Alarm setting: 0:Disable 1:Enable
1.3.6.1.4.1.4756.20.660.20.1.23ColumnfCCFSFPVenderNameLocalread-onlycurrentFRM220-CCF Serial cards SFP Vender Name.
1.3.6.1.4.1.4756.20.660.20.1.24ColumnfCCFSFPPartNoLocalread-onlycurrentFRM220-CCF Serial cards SFP Part Number.
1.3.6.1.4.1.4756.20.660.20.1.25ColumnfCCFSFPFiberTypeLocalread-onlycurrentFRM220-CCF Serial cards SFP Fiber Type: 0:Multi 1:Single 2:Unknown
1.3.6.1.4.1.4756.20.660.20.1.26ColumnfCCFSFPWaveLength1Localread-onlycurrentFRM220-CCF Serial cards SFP Transmitter Wave Length.
1.3.6.1.4.1.4756.20.660.20.1.27ColumnfCCFSFPWaveLength2Localread-onlycurrentFRM220-CCF Serial cards SFP Receiver Wave Length.
1.3.6.1.4.1.4756.20.660.20.1.28ColumnfCCFSFPLinkLengthLocalread-onlycurrentFRM220-CCF Serial cards SFP Link Length.
1.3.6.1.4.1.4756.20.660.20.1.29ColumnfCCFSFPTxPowerLocalread-onlycurrentFRM220-CCF Serial cards SFP Tx Power.
1.3.6.1.4.1.4756.20.660.20.1.30ColumnfCCFSFPRxPowerLocalread-onlycurrentFRM220-CCF Serial cards SFP Rx Power.
1.3.6.1.4.1.4756.20.660.20.1.31ColumnfCCFSFPRxSensLocalread-onlycurrentFRM220-CCF Serial cards SFP Rx Sensitivity.
1.3.6.1.4.1.4756.20.660.20.1.32ColumnfCCFSFPRxPwrMarginLocalread-onlycurrentFRM220-CCF Serial cards SFP Rx Power Margin.
1.3.6.1.4.1.4756.20.660.20.1.33ColumnfCCFSFPTemperatureLocalread-onlycurrentFRM220-CCF Serial cards SFP Temperature.
1.3.6.1.4.1.4756.20.660.20.1.34ColumnfCCFSFPSupplyVoltageLocalread-onlycurrentFRM220-CCF Serial cards SFP Supper Voltage.
1.3.6.1.4.1.4756.20.660.20.1.35ColumnfCCFSFPTxLaserBiasLocalread-onlycurrentFRM220-CCF Serial cards SFP Tx Laser Bias.
1.3.6.1.4.1.4756.20.660.20.1.36ColumnfCCFChannel1InputLocalread-onlycurrentFRM220-CCF Serial cards Channel 1 Input.
1.3.6.1.4.1.4756.20.660.20.1.37ColumnfCCFChannel1OutputLocalread-onlycurrentFRM220-CCF Serial cards Channel 1 Output.
1.3.6.1.4.1.4756.20.660.20.1.38ColumnfCCFChannel1RelayLocalread-writecurrentFRM220-CCF Serial cards Channel 1 Relay Control: 0:By Input 1:Force Off 2:Force On 3:Fiber Sync Loss Off 4:Fiber Sync Loss On 5:Non Support
1.3.6.1.4.1.4756.20.660.20.1.39ColumnfCCFChannel2InputLocalread-onlycurrentFRM220-CCF Serial cards Channel 2 Input.
1.3.6.1.4.1.4756.20.660.20.1.40ColumnfCCFChannel2OutputLocalread-onlycurrentFRM220-CCF Serial cards Channel 2 Output.
1.3.6.1.4.1.4756.20.660.20.1.41ColumnfCCFChannel2RelayLocalread-writecurrentFRM220-CCF Serial cards Channel 2 Relay Control: 0:By Input 1:Force Off 2:Force On 3:Fiber Sync Loss Off 4:Fiber Sync Loss On 5:Non Support
1.3.6.1.4.1.4756.20.660.20.1.42ColumnfCCFChannel3InputLocalread-onlycurrentFRM220-CCF Serial cards Channel 3 Input.
1.3.6.1.4.1.4756.20.660.20.1.43ColumnfCCFChannel3OutputLocalread-onlycurrentFRM220-CCF Serial cards Channel 3 Output.
1.3.6.1.4.1.4756.20.660.20.1.44ColumnfCCFChannel3RelayLocalread-writecurrentFRM220-CCF Serial cards Channel 3 Relay Control: 0:By Input 1:Force Off 2:Force On 3:Fiber Sync Loss Off 4:Fiber Sync Loss On 5:Non Support
1.3.6.1.4.1.4756.20.660.20.1.45ColumnfCCFChannel4InputLocalread-onlycurrentFRM220-CCF Serial cards Channel 4 Input.
1.3.6.1.4.1.4756.20.660.20.1.46ColumnfCCFChannel4OutputLocalread-onlycurrentFRM220-CCF Serial cards Channel 4 Output.
1.3.6.1.4.1.4756.20.660.20.1.47ColumnfCCFChannel4RelayLocalread-writecurrentFRM220-CCF Serial cards Channel 4 Relay Control: 0:By Input 1:Force Off 2:Force On 3:Fiber Sync Loss Off 4:Fiber Sync Loss On 5:Non Support
1.3.6.1.4.1.4756.20.661NodefCCFRemoteCards
1.3.6.1.4.1.4756.20.661.20TablefCCFRemoteTablenot-accessiblecurrentA list of local FRM220-CCF Serial cards entries. The number of entries is fCCF-No-R.
1.3.6.1.4.1.4756.20.661.20.1RowfCCFRemoteEntrynot-accessiblecurrentAn entry containing management information applicable to a particular local FRM220-CCF series card.
1.3.6.1.4.1.4756.20.661.20.1.1ColumnfCCFChassisIndexRemoteread-onlycurrentA unique value for each card. It starts from 0 to 9 contiguously.
1.3.6.1.4.1.4756.20.661.20.1.2ColumnfCCFSlotIndexRemoteread-onlycurrentA unique value for each card. It starts from 1 to 20 contiguously.
1.3.6.1.4.1.4756.20.661.20.1.3ColumnfCCFCardHWVerRemoteread-onlycurrentFRM220-CCF Serial cards hardware version x.xxx
1.3.6.1.4.1.4756.20.661.20.1.4ColumnfCCFCardFWVerRemoteread-onlycurrentFRM220-CCF Serial cards firmware version x.xxx
1.3.6.1.4.1.4756.20.661.20.1.5ColumnfCCFCardCPLDVerRemoteread-onlycurrentFRM220-CCF Serial cards CPLD version x.xxx
1.3.6.1.4.1.4756.20.661.20.1.6ColumnfCCFCardFPGAVerRemoteread-onlycurrentFRM220-CCF Serial cards FPGA version x.xxx
1.3.6.1.4.1.4756.20.661.20.1.7ColumnfCCFCardModelRemoteread-onlycurrentThe CCF Serial cards Model type as below: 0:FRM220-CCF20 1:FRM220-CCF40 8:IFC-CCF20-HP 9:IFC-CCF40-HP
1.3.6.1.4.1.4756.20.661.20.1.8ColumnfCCFPortResetRemoteread-onlycurrentCCF card Port Reset feature: 0:Inactive 1:Active
1.3.6.1.4.1.4756.20.661.20.1.9ColumnfCCFSetToDefaultRemoteread-onlycurrentCCF card Set To Default feature: 0:Inactive 1:Active
1.3.6.1.4.1.4756.20.661.20.1.10ColumnfCCFSFPExistRemoteread-onlycurrentFRM220-CCF Serial cards SFP Exist Information.
1.3.6.1.4.1.4756.20.661.20.1.11ColumnfCCFSFPTypeRemoteread-onlycurrentFRM220-CCF Serial cards SFP Type Information.
1.3.6.1.4.1.4756.20.661.20.1.12ColumnfCCFSFPTxFailureRemoteread-onlycurrentFRM220-CCF Serial cards SFP Tx Failure Information.
1.3.6.1.4.1.4756.20.661.20.1.13ColumnfCCFSFPLinkRemoteread-onlycurrentFRM220-CCF Serial cards SFP Link Information.
1.3.6.1.4.1.4756.20.661.20.1.14ColumnfCCFSFPSyncRemoteread-onlycurrentFRM220-CCF Serial cards SFP Sync Information.
1.3.6.1.4.1.4756.20.661.20.1.15ColumnfCCFSFPLoopBackRemoteread-onlycurrentFRM220-CCF Serial cards SFP Loopback Information.
1.3.6.1.4.1.4756.20.661.20.1.16ColumnfCCFSFPPortActiveRemoteread-writecurrentFRM220-CCF Serial cards Port Active: 0:disable 1:enable
1.3.6.1.4.1.4756.20.661.20.1.17ColumnfCCFSFPALSRemoteread-writecurrentFRM220-CCF Serial cards Auto Laser Shutdown (ALS): 0:disable 1:enable
1.3.6.1.4.1.4756.20.661.20.1.18ColumnfCCFDeviceAlarmRemoteread-onlycurrentFRM220-CCF Serial cards Alarm Status.
1.3.6.1.4.1.4756.20.661.20.1.19ColumnfCCFDeviceActiveRemoteread-writecurrentFRM220-CCF Serial cards Device Active: 0:Disable 1:Enable
1.3.6.1.4.1.4756.20.661.20.1.20ColumnfCCFDeviceDebounceRemoteread-writecurrentFRM220-CCF Serial cards Input Debounce: 0:Disable 1:Enable
1.3.6.1.4.1.4756.20.661.20.1.21ColumnfCCFSFPVenderNameRemoteread-onlycurrentFRM220-CCF Serial cards SFP Vender Name.
1.3.6.1.4.1.4756.20.661.20.1.22ColumnfCCFSFPPartNoRemoteread-onlycurrentFRM220-CCF Serial cards SFP Part Number.
1.3.6.1.4.1.4756.20.661.20.1.23ColumnfCCFSFPFiberTypeRemoteread-onlycurrentFRM220-CCF Serial cards SFP Fiber Type: 0:Multi 1:Single 2:Unknown
1.3.6.1.4.1.4756.20.661.20.1.24ColumnfCCFSFPWaveLength1Remoteread-onlycurrentFRM220-CCF Serial cards SFP Transmitter Wave Length.
1.3.6.1.4.1.4756.20.661.20.1.25ColumnfCCFSFPWaveLength2Remoteread-onlycurrentFRM220-CCF Serial cards SFP Receiver Wave Length.
1.3.6.1.4.1.4756.20.661.20.1.26ColumnfCCFSFPLinkLengthRemoteread-onlycurrentFRM220-CCF Serial cards SFP Link Length.
1.3.6.1.4.1.4756.20.661.20.1.27ColumnfCCFSFPTxPowerRemoteread-onlycurrentFRM220-CCF Serial cards SFP Tx Power.
1.3.6.1.4.1.4756.20.661.20.1.28ColumnfCCFSFPRxPowerRemoteread-onlycurrentFRM220-CCF Serial cards SFP Rx Power.
1.3.6.1.4.1.4756.20.661.20.1.29ColumnfCCFSFPRxSensRemoteread-onlycurrentFRM220-CCF Serial cards SFP Rx Sensitivity.
1.3.6.1.4.1.4756.20.661.20.1.30ColumnfCCFSFPRxPwrMarginRemoteread-onlycurrentFRM220-CCF Serial cards SFP Rx Power Margin.
1.3.6.1.4.1.4756.20.661.20.1.31ColumnfCCFSFPTemperatureRemoteread-onlycurrentFRM220-CCF Serial cards SFP Temperature.
1.3.6.1.4.1.4756.20.661.20.1.32ColumnfCCFSFPSupplyVoltageRemoteread-onlycurrentFRM220-CCF Serial cards SFP Supper Voltage.
1.3.6.1.4.1.4756.20.661.20.1.33ColumnfCCFSFPTxLaserBiasRemoteread-onlycurrentFRM220-CCF Serial cards SFP Tx Laser Bias.
1.3.6.1.4.1.4756.20.661.20.1.34ColumnfCCFChannel1InputRemoteread-onlycurrentFRM220-CCF Serial cards Channel 1 Input.
1.3.6.1.4.1.4756.20.661.20.1.35ColumnfCCFChannel1OutputRemoteread-onlycurrentFRM220-CCF Serial cards Channel 1 Output.
1.3.6.1.4.1.4756.20.661.20.1.36ColumnfCCFChannel1RelayRemoteread-writecurrentFRM220-CCF Serial cards Channel 1 Relay Control: 0:By Input 1:Force Off 2:Force On 3:Fiber Sync Loss Off 4:Fiber Sync Loss On 5:Non Support
1.3.6.1.4.1.4756.20.661.20.1.37ColumnfCCFChannel2InputRemoteread-onlycurrentFRM220-CCF Serial cards Channel 2 Input.
1.3.6.1.4.1.4756.20.661.20.1.38ColumnfCCFChannel2OutputRemoteread-onlycurrentFRM220-CCF Serial cards Channel 2 Output.
1.3.6.1.4.1.4756.20.661.20.1.39ColumnfCCFChannel2RelayRemoteread-writecurrentFRM220-CCF Serial cards Channel 2 Relay Control: 0:By Input 1:Force Off 2:Force On 3:Fiber Sync Loss Off 4:Fiber Sync Loss On 5:Non Support
1.3.6.1.4.1.4756.20.661.20.1.40ColumnfCCFChannel3InputRemoteread-onlycurrentFRM220-CCF Serial cards Channel 3 Input.
1.3.6.1.4.1.4756.20.661.20.1.41ColumnfCCFChannel3OutputRemoteread-onlycurrentFRM220-CCF Serial cards Channel 3 Output.
1.3.6.1.4.1.4756.20.661.20.1.42ColumnfCCFChannel3RelayRemoteread-writecurrentFRM220-CCF Serial cards Channel 3 Relay Control: 0:By Input 1:Force Off 2:Force On 3:Fiber Sync Loss Off 4:Fiber Sync Loss On 5:Non Support
1.3.6.1.4.1.4756.20.661.20.1.43ColumnfCCFChannel4InputRemoteread-onlycurrentFRM220-CCF Serial cards Channel 4 Input.
1.3.6.1.4.1.4756.20.661.20.1.44ColumnfCCFChannel4OutputRemoteread-onlycurrentFRM220-CCF Serial cards Channel 4 Output.
1.3.6.1.4.1.4756.20.661.20.1.45ColumnfCCFChannel4RelayRemoteread-writecurrentFRM220-CCF Serial cards Channel 4 Relay Control: 0:By Input 1:Force Off 2:Force On 3:Fiber Sync Loss Off 4:Fiber Sync Loss On 5:Non Support
1.3.6.1.4.1.4756.20.661.20.1.46ColumnfCCFDSSChannel1ThresholdRemoteread-onlycurrentFRM220-CCF Serial cards Channel 1 Thresold.
1.3.6.1.4.1.4756.20.661.20.1.47ColumnfCCFDSSChannel2ThresholdRemoteread-onlycurrentFRM220-CCF Serial cards Channel 2 Thresold.
1.3.6.1.4.1.4756.20.661.20.1.48ColumnfCCFDSSChannel3ThresholdRemoteread-onlycurrentFRM220-CCF Serial cards Channel 3 Thresold.
1.3.6.1.4.1.4756.20.661.20.1.49ColumnfCCFDSSChannel4ThresholdRemoteread-onlycurrentFRM220-CCF Serial cards Channel 4 Thresold.
1.3.6.1.4.1.4756.20.670Nodef4G3RCards
1.3.6.1.4.1.4756.20.670.20Tablef4G3RTablenot-accessiblecurrentA list of local FRM220-4G-3R card entries. The number of entries is f4G3R-No-L.
1.3.6.1.4.1.4756.20.670.20.1Rowf4G3REntrynot-accessiblecurrentAn entry containing management information applicable to a particular local FRM220-4G-3R card.
1.3.6.1.4.1.4756.20.670.20.1.1Columnf4G3RChassisIndexread-onlycurrentA unique value for each local card. It is the chassis location number.
1.3.6.1.4.1.4756.20.670.20.1.2Columnf4G3RSlotIndexread-onlycurrentA unique value for each local card. It is the slot location number.
1.3.6.1.4.1.4756.20.670.20.1.3Columnf4G3RCardHWVerread-onlycurrentLocal FRM220-4G-3R card hardware version x.xxx
1.3.6.1.4.1.4756.20.670.20.1.4Columnf4G3RCardFWVerread-onlycurrentLocal FRM220-4G-3R card firmware version x.xxx
1.3.6.1.4.1.4756.20.670.20.1.5Columnf4G3RCardCPLDVerread-onlycurrentLocal FRM220-4G-3R card CPLD version x.xxx
1.3.6.1.4.1.4756.20.670.20.1.6Columnf4G3RCardFPGAVerread-onlycurrentLocal FRM220-4G-3R card FPGA version x.xxx
1.3.6.1.4.1.4756.20.670.20.1.7Columnf4G3RFx1Linkread-onlycurrentLocal FRM220-4G-3R card Fiber1 link status: 0:Down 1:Up
1.3.6.1.4.1.4756.20.670.20.1.8Columnf4G3RFx2Linkread-onlycurrentLocal FRM220-4G-3R card Fiber2 link status: 0:Down 1:Up
1.3.6.1.4.1.4756.20.670.20.1.9Columnf4G3RFx3Linkread-onlycurrentLocal FRM220-4G-3R card Fiber3 link status: 0:Down 1:Up
1.3.6.1.4.1.4756.20.670.20.1.10Columnf4G3RFx4Linkread-onlycurrentLocal FRM220-4G-3R card Fiber4 link status: 0:Down 1:Up
1.3.6.1.4.1.4756.20.670.20.1.11Columnf4G3RFx1CDRLockedread-onlycurrentLocal FRM220-4G-3R card Fiber1 CRD Locked: 0:Not Locked 1:Locked
1.3.6.1.4.1.4756.20.670.20.1.12Columnf4G3RFx2CDRLockedread-onlycurrentLocal FRM220-4G-3R card Fiber2 CRD Locked: 0:Not Locked 1:Locked
1.3.6.1.4.1.4756.20.670.20.1.13Columnf4G3RFx3CDRLockedread-onlycurrentLocal FRM220-4G-3R card Fiber3 CRD Locked: 0:Not Locked 1:Locked
1.3.6.1.4.1.4756.20.670.20.1.14Columnf4G3RFx4CDRLockedread-onlycurrentLocal FRM220-4G-3R card Fiber4 CRD Locked: 0:Not Locked 1:Locked
1.3.6.1.4.1.4756.20.670.20.1.15Columnf4G3RFx1TxFaultread-onlycurrentLocal FRM220-4G-3R card Fiber1 Tx Fault: 0:Normal 1:Failure
1.3.6.1.4.1.4756.20.670.20.1.16Columnf4G3RFx2TxFaultread-onlycurrentLocal FRM220-4G-3R card Fiber2 Tx Fault: 0:Normal 1:Failure
1.3.6.1.4.1.4756.20.670.20.1.17Columnf4G3RFx3TxFaultread-onlycurrentLocal FRM220-4G-3R card Fiber3 Tx Fault: 0:Normal 1:Failure
1.3.6.1.4.1.4756.20.670.20.1.18Columnf4G3RFx4TxFaultread-onlycurrentLocal FRM220-4G-3R card Fiber4 Tx Fault: 0:Normal 1:Failure
1.3.6.1.4.1.4756.20.670.20.1.19Columnf4G3RFx1DDread-onlycurrentLocal FRM220-4G-3R card fiber1 Digital Diagnostic function: 0:No 1:Yes
1.3.6.1.4.1.4756.20.670.20.1.20Columnf4G3RFx2DDread-onlycurrentLocal FRM220-4G-3R card fiber2 Digital Diagnostic function: 0:No 1:Yes
1.3.6.1.4.1.4756.20.670.20.1.21Columnf4G3RFx3DDread-onlycurrentLocal FRM220-4G-3R card fiber3 Digital Diagnostic function: 0:No 1:Yes
1.3.6.1.4.1.4756.20.670.20.1.22Columnf4G3RFx4DDread-onlycurrentLocal FRM220-4G-3R card fiber4 Digital Diagnostic function: 0:No 1:Yes
1.3.6.1.4.1.4756.20.670.20.1.23Columnf4G3RFx1DDStatusread-onlycurrentLocal FRM220-4G-3R card fiber1 D/D information: Status Support
1.3.6.1.4.1.4756.20.670.20.1.24Columnf4G3RFx2DDStatusread-onlycurrentLocal FRM220-4G-3R card fiber2 D/D information: Status Support
1.3.6.1.4.1.4756.20.670.20.1.25Columnf4G3RFx3DDStatusread-onlycurrentLocal FRM220-4G-3R card fiber3 D/D information: Status Support
1.3.6.1.4.1.4756.20.670.20.1.26Columnf4G3RFx4DDStatusread-onlycurrentLocal FRM220-4G-3R card fiber4 D/D information: Status Support
1.3.6.1.4.1.4756.20.670.20.1.27Columnf4G3RDeviceActiveread-writecurrentLocal FRM220-4G-3R card active: 0:Inactive 1:Active
1.3.6.1.4.1.4756.20.670.20.1.28Columnf4G3RPortResetread-writecurrentForce local FRM220-4G-3R card to reset mode: 0:Off 1:Action
1.3.6.1.4.1.4756.20.670.20.1.29Columnf4G3RSetDefaultread-writecurrentLocal FRM220-4G-3R card set to default : 0:Off 1:Action
1.3.6.1.4.1.4756.20.670.20.1.30Columnf4G3RWorkModeread-writecurrentLocal FRM220-4G-3R card Work Mode : 0:Protection 1:Dual Channel
1.3.6.1.4.1.4756.20.670.20.1.31Columnf4G3RFx1Lbsettingread-writecurrentLocal FRM220-4G-3R card Fiber1 Loopback: 0:Disable 1:Enable
1.3.6.1.4.1.4756.20.670.20.1.32Columnf4G3RFx2Lbsettingread-writecurrentLocal FRM220-4G-3R card Fiber2 Loopback: 0:Disable 1:Enable
1.3.6.1.4.1.4756.20.670.20.1.33Columnf4G3RFx3Lbsettingread-writecurrentLocal FRM220-4G-3R card Fiber3 Loopback: 0:Disable 1:Enable
1.3.6.1.4.1.4756.20.670.20.1.34Columnf4G3RFx4Lbsettingread-writecurrentLocal FRM220-4G-3R card Fiber4 Loopback: 0:Disable 1:Enable
1.3.6.1.4.1.4756.20.670.20.1.35Columnf4G3RFx1LFPTread-writecurrentLocal FRM220-4G-3R card Fiber1 Link Fault Pass Through: 0:Disable 1:Enable
1.3.6.1.4.1.4756.20.670.20.1.36Columnf4G3RFx2LFPTread-writecurrentLocal FRM220-4G-3R card Fiber2 Link Fault Pass Through: 0:Disable 1:Enable
1.3.6.1.4.1.4756.20.670.20.1.37Columnf4G3RFx3LFPTread-writecurrentLocal FRM220-4G-3R card Fiber3 Link Fault Pass Through: 0:Disable 1:Enable
1.3.6.1.4.1.4756.20.670.20.1.38Columnf4G3RFx4LFPTread-writecurrentLocal FRM220-4G-3R card Fiber4 Link Fault Pass Through: 0:Disable 1:Enable
1.3.6.1.4.1.4756.20.670.20.1.39Columnf4G3RFx1ALSModeread-writecurrentLocal FRM220-4G-3R card Fiber1 Auto Laser Showdown: 0:Disable 1:Enable
1.3.6.1.4.1.4756.20.670.20.1.40Columnf4G3RFx2ALSModeread-writecurrentLocal FRM220-4G-3R card Fiber2 Auto Laser Showdown: 0:Disable 1:Enable
1.3.6.1.4.1.4756.20.670.20.1.41Columnf4G3RFx3ALSModeread-writecurrentLocal FRM220-4G-3R card Fiber3 Auto Laser Showdown: 0:Disable 1:Enable
1.3.6.1.4.1.4756.20.670.20.1.42Columnf4G3RFx4ALSModeread-writecurrentLocal FRM220-4G-3R card Fiber4 Auto Laser Showdown: 0:Disable 1:Enable
1.3.6.1.4.1.4756.20.670.20.1.43Columnf4G3RFx1LinkAlarmread-writecurrentLocal FRM220-4G-3R card Fx1 Link Alarm: 0:Disalbe 1:Enable
1.3.6.1.4.1.4756.20.670.20.1.44Columnf4G3RFx2LinkAlarmread-writecurrentLocal FRM220-4G-3R card Fx2 Link Alarm: 0:Disalbe 1:Enable
1.3.6.1.4.1.4756.20.670.20.1.45Columnf4G3RFx3LinkAlarmread-writecurrentLocal FRM220-4G-3R card Fx3 Link Alarm: 0:Disalbe 1:Enable
1.3.6.1.4.1.4756.20.670.20.1.46Columnf4G3RFx4LinkAlarmread-writecurrentLocal FRM220-4G-3R card Fx4 Link Alarm: 0:Disalbe 1:Enable
1.3.6.1.4.1.4756.20.670.20.1.47Columnf4G3R3R2RModeread-writecurrentLocal FRM220-4G-3R card 2R/3R Mode: 0:3R 1:2R
1.3.6.1.4.1.4756.20.670.20.1.48Columnf4G3RWorkingPathStatusread-onlycurrentLocal FRM220-4G-3R card Workinng Path Status (Protection mode only): 0:Primary 1:Secondary
1.3.6.1.4.1.4756.20.670.20.1.49Columnf4G3RWorkingPathread-writecurrentLocal FRM220-4G-3R card Workinng Path(Protection mode only): 0:Auto-Revert 1:Non Revert 2:Primary 3:Secondary
1.3.6.1.4.1.4756.20.670.20.1.50Columnf4G3RDataRatelStatusread-onlycurrentLocal FRM220-4G-3R card Data Rate 1 Status (3R Mode Only):
1.3.6.1.4.1.4756.20.670.20.1.51Columnf4G3RDataRate2Statusread-onlycurrentLocal FRM220-4G-3R card Data Rate 2 Status (3R Mode and Dual Channel Only):
1.3.6.1.4.1.4756.20.670.20.1.52Columnf4G3RProtocol1read-onlycurrentLocal FRM220-4G-3R card Protocol 1 (3R Mode Only): 0:Ethernet 1:SONET/SDH 2:Fiber Channel 3:CPRI 4:OBSAI 5:SDI/Other 6:Not Support
1.3.6.1.4.1.4756.20.670.20.1.53Columnf4G3RRate1read-writecurrentLocal FRM220-4G-3R card Rate 1 (3R Mode Only): Ethernet 0: 1GE SONET/SDH 8: OC-48/STM-16 9: OC-24 10: OC-12/STM-4 Fiber Channel 16: 4GFC 17: 2GFC 18: 1GFC CPRI…
1.3.6.1.4.1.4756.20.670.20.1.54Columnf4G3RProtocol2read-onlycurrentLocal FRM220-4G-3R Protocol 2 (3R Mode and Dual Channel Only): 0:Ethernet 1:SONET/SDH 2:Fiber Channel 3:CPRI 4:OBSAI 6:None
1.3.6.1.4.1.4756.20.670.20.1.55Columnf4G3RRate2read-writecurrentLocal FRM220-4G-3R card Rate 1 (3R Mode and Dual Channel Only): Ethernet 0: 1GE SONET/SDH 8: OC-48/STM-16 9:OC-24 10:OC-12/STM-4 Fiber Channel 16: 4GFC 17: 2GF…
1.3.6.1.4.1.4756.20.670.20.1.56Columnf4G3RChannel1Activeread-writecurrentLocal FRM220-4G-3R card Channel 1 Active(Dual Channel only): 0:Disable 1:Enable
1.3.6.1.4.1.4756.20.670.20.1.57Columnf4G3RChannel2Activeread-writecurrentLocal FRM220-4G-3R card Channel 2 Active(Dual Channel only): 0:Disable 1:Enable
1.3.6.1.4.1.4756.20.670.20.1.58Columnf4G3RFx1DDVendorread-onlycurrentLocal FRM220-4G-3R card fiber1 D/D information: Vendor name
1.3.6.1.4.1.4756.20.670.20.1.59Columnf4G3RFx1DDPartNoread-onlycurrentLocal FRM220-4G-3R card fiber1 D/D information: Vendor part number
1.3.6.1.4.1.4756.20.670.20.1.60Columnf4G3RFx1DDVendorSNread-onlycurrentLocal FRM220-4G-3R card fiber1 D/D information: Vendor Serial Number
1.3.6.1.4.1.4756.20.670.20.1.61Columnf4G3RFx1DDFiberTyperead-onlycurrentLocal FRM220-4G-3R card fiber1 D/D information: Fiber Type
1.3.6.1.4.1.4756.20.670.20.1.62Columnf4G3RFx1DDWaveLenread-onlycurrentLocal FRM220-4G-3R card fiber1 D/D information: Wave length
1.3.6.1.4.1.4756.20.670.20.1.63Columnf4G3RFx1DDWaveLen2read-onlycurrentLocal FRM220-4G-3R card fiber1 D/D information: Wave length 2
1.3.6.1.4.1.4756.20.670.20.1.64Columnf4G3RFx1DDLinkLenread-onlycurrentLocal FRM220-4G-3R card fiber1 D/D information: Link length
1.3.6.1.4.1.4756.20.670.20.1.65Columnf4G3RFx1DDLenUnitread-onlycurrentLocal FRM220-4G-3R card fiber1 D/D information: Length Unit
1.3.6.1.4.1.4756.20.670.20.1.66Columnf4G3RFx1DDRxSensread-onlycurrentLocal FRM220-4G-3R card fiber1 D/D information: Rx Sensitivity
1.3.6.1.4.1.4756.20.670.20.1.67Columnf4G3RFx1DDTxPWRread-onlycurrentLocal FRM220-4G-3R card fiber1 D/D information: Tx power
1.3.6.1.4.1.4756.20.670.20.1.68Columnf4G3RFx1DDRxPWRread-onlycurrentLocal FRM220-4G-3R card fiber1 D/D information: Rx power
1.3.6.1.4.1.4756.20.670.20.1.69Columnf4G3RFx1RxPowerStatusread-onlycurrentLocal FRM220-4G-3R card fiber1 Rx Power Status: 0:Normal 1:Warning 2:Alarm
1.3.6.1.4.1.4756.20.670.20.1.70Columnf4G3RFx1DDTempread-onlycurrentLocal FRM220-4G-3R card fiber1 D/D information: Temperature in degree C
1.3.6.1.4.1.4756.20.670.20.1.71Columnf4G3RFx1DDPWRMarginread-onlycurrentLocal FRM220-4G-3R card fiber1 D/D information: Power margin
1.3.6.1.4.1.4756.20.670.20.1.72Columnf4G3RFx2DDVendorread-onlycurrentLocal FRM220-4G-3R card fiber2 D/D information: Vendor name
1.3.6.1.4.1.4756.20.670.20.1.73Columnf4G3RFx2DDPartNoread-onlycurrentLocal FRM220-4G-3R card fiber2 D/D information: Vendor part number
1.3.6.1.4.1.4756.20.670.20.1.74Columnf4G3RFx2DDVendorSNread-onlycurrentLocal FRM220-4G-3R card fiber2 D/D information: Vendor Serial Number
1.3.6.1.4.1.4756.20.670.20.1.75Columnf4G3RFx2DDFiberTyperead-onlycurrentLocal FRM220-4G-3R card fiber2 D/D information: Fiber Type
1.3.6.1.4.1.4756.20.670.20.1.76Columnf4G3RFx2DDWaveLenread-onlycurrentLocal FRM220-4G-3R card fiber2 D/D information: Wave length
1.3.6.1.4.1.4756.20.670.20.1.77Columnf4G3RFx2DDWaveLen2read-onlycurrentLocal FRM220-4G-3R card fiber2 D/D information: Wave length 2
1.3.6.1.4.1.4756.20.670.20.1.78Columnf4G3RFx2DDLinkLenread-onlycurrentLocal FRM220-4G-3R card fiber2 D/D information: Link length
1.3.6.1.4.1.4756.20.670.20.1.79Columnf4G3RFx2DDLenUnitread-onlycurrentLocal FRM220-4G-3R card fiber2 D/D information: Length Unit
1.3.6.1.4.1.4756.20.670.20.1.80Columnf4G3RFx2DDRxSensread-onlycurrentLocal FRM220-4G-3R card fiber2 D/D information: Rx Sensitivity
1.3.6.1.4.1.4756.20.670.20.1.81Columnf4G3RFx2DDTxPWRread-onlycurrentLocal FRM220-4G-3R card fiber2 D/D information: Tx power
1.3.6.1.4.1.4756.20.670.20.1.82Columnf4G3RFx2DDRxPWRread-onlycurrentLocal FRM220-4G-3R card fiber2 D/D information: Rx power
1.3.6.1.4.1.4756.20.670.20.1.83Columnf4G3RFx2RxPowerStatusread-onlycurrentLocal FRM220-4G-3R card fiber2 Rx Power Status: 0:Normal 1:Warning 2:Alarm
1.3.6.1.4.1.4756.20.670.20.1.84Columnf4G3RFx2DDTempread-onlycurrentLocal FRM220-4G-3R card fiber2 D/D information: Temperature in degree C
1.3.6.1.4.1.4756.20.670.20.1.85Columnf4G3RFx2DDPWRMarginread-onlycurrentLocal FRM220-4G-3R card fiber2 D/D information: Power margin
1.3.6.1.4.1.4756.20.670.20.1.86Columnf4G3RFx3DDVendorread-onlycurrentLocal FRM220-4G-3R card fiber3 D/D information: Vendor name
1.3.6.1.4.1.4756.20.670.20.1.87Columnf4G3RFx3DDPartNoread-onlycurrentLocal FRM220-4G-3R card fiber3 D/D information: Vendor part number
1.3.6.1.4.1.4756.20.670.20.1.88Columnf4G3RFx3DDVendorSNread-onlycurrentLocal FRM220-4G-3R card fiber3 D/D information: Vendor Serial Number
1.3.6.1.4.1.4756.20.670.20.1.89Columnf4G3RFx3DDFiberTyperead-onlycurrentLocal FRM220-4G-3R card fiber3 D/D information: Fiber Type
1.3.6.1.4.1.4756.20.670.20.1.90Columnf4G3RFx3DDWaveLenread-onlycurrentLocal FRM220-4G-3R card fiber3 D/D information: Wave length
1.3.6.1.4.1.4756.20.670.20.1.91Columnf4G3RFx3DDWaveLen2read-onlycurrentLocal FRM220-4G-3R card fiber3 D/D information: Wave length 2
1.3.6.1.4.1.4756.20.670.20.1.92Columnf4G3RFx3DDLinkLenread-onlycurrentLocal FRM220-4G-3R card fiber3 D/D information: Link length
1.3.6.1.4.1.4756.20.670.20.1.93Columnf4G3RFx3DDLenUnitread-onlycurrentLocal FRM220-4G-3R card fiber3 D/D information: Length Unit
1.3.6.1.4.1.4756.20.670.20.1.94Columnf4G3RFx3DDRxSensread-onlycurrentLocal FRM220-4G-3R card fiber3 D/D information: Rx Sensitivity
1.3.6.1.4.1.4756.20.670.20.1.95Columnf4G3RFx3DDTxPWRread-onlycurrentLocal FRM220-4G-3R card fiber3 D/D information: Tx power
1.3.6.1.4.1.4756.20.670.20.1.96Columnf4G3RFx3DDRxPWRread-onlycurrentLocal FRM220-4G-3R card fiber3 D/D information: Rx power
1.3.6.1.4.1.4756.20.670.20.1.97Columnf4G3RFx3RxPowerStatusread-onlycurrentLocal FRM220-4G-3R card fiber3 Rx Power Status: 0:Normal 1:Warning 2:Alarm
1.3.6.1.4.1.4756.20.670.20.1.98Columnf4G3RFx3DDTempread-onlycurrentLocal FRM220-4G-3R card fiber3 D/D information: Temperature in degree C
1.3.6.1.4.1.4756.20.670.20.1.99Columnf4G3RFx3DDPWRMarginread-onlycurrentLocal FRM220-4G-3R card fiber3 D/D information: Power margin
1.3.6.1.4.1.4756.20.670.20.1.100Columnf4G3RFx4DDVendorread-onlycurrentLocal FRM220-4G-3R card fiber4 D/D information: Vendor name
1.3.6.1.4.1.4756.20.670.20.1.101Columnf4G3RFx4DDPartNoread-onlycurrentLocal FRM220-4G-3R card fiber4 D/D information: Vendor part number
1.3.6.1.4.1.4756.20.670.20.1.102Columnf4G3RFx4DDVendorSNread-onlycurrentLocal FRM220-4G-3R card fiber4 D/D information: Vendor Serial Number
1.3.6.1.4.1.4756.20.670.20.1.103Columnf4G3RFx4DDFiberTyperead-onlycurrentLocal FRM220-4G-3R card fiber4 D/D information: Fiber Type
1.3.6.1.4.1.4756.20.670.20.1.104Columnf4G3RFx4DDWaveLenread-onlycurrentLocal FRM220-4G-3R card fiber4 D/D information: Wave length
1.3.6.1.4.1.4756.20.670.20.1.105Columnf4G3RFx4DDWaveLen2read-onlycurrentLocal FRM220-4G-3R card fiber4 D/D information: Wave length 2
1.3.6.1.4.1.4756.20.670.20.1.106Columnf4G3RFx4DDLinkLenread-onlycurrentLocal FRM220-4G-3R card fiber4 D/D information: Link length
1.3.6.1.4.1.4756.20.670.20.1.107Columnf4G3RFx4DDLenUnitread-onlycurrentLocal FRM220-4G-3R card fiber4 D/D information: Length Unit
1.3.6.1.4.1.4756.20.670.20.1.108Columnf4G3RFx4DDRxSensread-onlycurrentLocal FRM220-4G-3R card fiber4 D/D information: Rx Sensitivity
1.3.6.1.4.1.4756.20.670.20.1.109Columnf4G3RFx4DDTxPWRread-onlycurrentLocal FRM220-4G-3R card fiber4 D/D information: Tx power
1.3.6.1.4.1.4756.20.670.20.1.110Columnf4G3RFx4DDRxPWRread-onlycurrentLocal FRM220-4G-3R card fiber4 D/D information: Rx power
1.3.6.1.4.1.4756.20.670.20.1.111Columnf4G3RFx4RxPowerStatusread-onlycurrentLocal FRM220-4G-3R card fiber4 Rx Power Status: 0:Normal 1:Warning 2:Alarm
1.3.6.1.4.1.4756.20.670.20.1.112Columnf4G3RFx4DDTempread-onlycurrentLocal FRM220-4G-3R card fiber4 D/D information: Temperature in degree C
1.3.6.1.4.1.4756.20.670.20.1.113Columnf4G3RFx4DDPWRMarginread-onlycurrentLocal FRM220-4G-3R card fiber4 D/D information: Power margin
1.3.6.1.4.1.4756.20.670.20.1.114Columnf4G3RFx1RxPowerStatusAlarmread-writecurrentLocal FRM220-4G-3R card Line Rx Power Status trap. 0:Disable 1:Enable
1.3.6.1.4.1.4756.20.670.20.1.115Columnf4G3RFx1LosAssertAlarmread-writecurrentLocal FRM220-4G-3R card Line LOS Assert trap. 0:Disable 1:Enable
1.3.6.1.4.1.4756.20.670.20.1.116Columnf4G3RFx1RxPowerWarningThresholdread-writecurrentSet Line Rx Power Warning Threshold: Input range is from -60 to +10.
1.3.6.1.4.1.4756.20.670.20.1.117Columnf4G3RFx1RxPowerAlarmThresholdread-writecurrentSet Line Rx Power Alarm Threshold: Input range is from -60 to +10.
1.3.6.1.4.1.4756.20.670.20.1.118Columnf4G3RFx2RxPowerStatusAlarmread-writecurrentLocal FRM220-4G-3R card Primary Rx Power Status trap. 0:Disable 1:Enable
1.3.6.1.4.1.4756.20.670.20.1.119Columnf4G3RFx2LosAssertAlarmread-writecurrentLocal FRM220-4G-3R card Primary LOS Assert trap. 0:Disable 1:Enable
1.3.6.1.4.1.4756.20.670.20.1.120Columnf4G3RFx2RxPowerWarningThresholdread-writecurrentSet Primary Rx Power Warning Threshold: Input range is from -60 to +10.
1.3.6.1.4.1.4756.20.670.20.1.121Columnf4G3RFx2RxPowerAlarmThresholdread-writecurrentSet Primary Rx Power Alarm Threshold: Input range is from -60 to +10.
1.3.6.1.4.1.4756.20.670.20.1.122Columnf4G3RFx3RxPowerStatusAlarmread-writecurrentLocal FRM220-4G-3R card Secondary Rx Power Status trap. 0:Disable 1:Enable
1.3.6.1.4.1.4756.20.670.20.1.123Columnf4G3RFx3LosAssertAlarmread-writecurrentLocal FRM220-4G-3R card Secondary LOS Assert trap. 0:Disable 1:Enable
1.3.6.1.4.1.4756.20.670.20.1.124Columnf4G3RFx3RxPowerWarningThresholdread-writecurrentSet Secondary Rx Power Warning Threshold: Input range is from -60 to +10.
1.3.6.1.4.1.4756.20.670.20.1.125Columnf4G3RFx3RxPowerAlarmThresholdread-writecurrentSet Secondary Rx Power Alarm Threshold: Input range is from -60 to +10.
1.3.6.1.4.1.4756.20.670.20.1.126Columnf4G3RFx4RxPowerStatusAlarmread-writecurrentLocal FRM220-4G-3R card Fx4 Rx Power Status trap. 0:Disable 1:Enable
1.3.6.1.4.1.4756.20.670.20.1.127Columnf4G3RFx4LosAssertAlarmread-writecurrentLocal FRM220-4G-3R card Fx4 LOS Assert trap. 0:Disable 1:Enable
1.3.6.1.4.1.4756.20.670.20.1.128Columnf4G3RFx4RxPowerWarningThresholdread-writecurrentSet Secondary Rx Power Warning Threshold: Input range is from -60 to +10.
1.3.6.1.4.1.4756.20.670.20.1.129Columnf4G3RFx4RxPowerAlarmThresholdread-writecurrentSet Secondary Rx Power Alarm Threshold: Input range is from -60 to +10.
1.3.6.1.4.1.4756.20.670.20.1.130Columnf4G3RTemperatureread-onlycurrentLocal FRM220-4G-3R card temperature information: Temperature in degree C
1.3.6.1.4.1.4756.20.670.20.1.131Columnf4G3RPowerLedread-onlycurrentLocal FRM220-4G-3R card Powe Led. 0:ON (Power ON) 1:Flash (Standby; 1s ON/1s OFF)
1.3.6.1.4.1.4756.20.670.20.1.132Columnf4G3RSystemLedread-onlycurrentLocal FRM220-4G-3R card Syetem Led. 0:OFF(Fail) 1:ON (Normal)
1.3.6.1.4.1.4756.20.670.20.1.133Columnf4G3RModeLedread-onlycurrentLocal FRM220-4G-3R card Mode Led. 0:OFF(Dual Channel) 1:ON (Protection)
1.3.6.1.4.1.4756.20.670.20.1.134Columnf4G3RTestLedread-onlycurrentLocal FRM220-4G-3R card Test Led. 0:OFF(Normal) 1:ON (Test; Loopback Test)
1.3.6.1.4.1.4756.20.670.20.1.135Columnf4G3RFx1Ledread-onlycurrentLocal FRM220-4G-3R card Fx1 Led. 0:OFF(Link Down) 1:ON (SYNC) 2:LB (0.1s ON/0.1s OFF) 3:Link Up (0.5s ON/0.5s OFF)
1.3.6.1.4.1.4756.20.670.20.1.136Columnf4G3RFx2Ledread-onlycurrentLocal FRM220-4G-3R card Fx2 Led. 0:OFF(Link Down) 1:ON (SYNC) 2:LB (0.1s ON/0.1s OFF) 3:Link Up (0.5s ON/0.5s OFF) 4:Working Path (3s ON/0.2s OFF)
1.3.6.1.4.1.4756.20.670.20.1.137Columnf4G3RFx3Ledread-onlycurrentLocal FRM220-4G-3R card Fx3 Led. 0:OFF(Link Down) 1:ON (SYNC) 2:LB (0.1s ON/0.1s OFF) 3:Link Up (0.5s ON/0.5s OFF) 4:Working Path (3s ON/0.2s OFF)
1.3.6.1.4.1.4756.20.670.20.1.138Columnf4G3RFx4Ledread-onlycurrentLocal FRM220-4G-3R card Fx4 Led. 0:OFF(Link Down) 1:ON (SYNC) 2:LB (0.1s ON/0.1s OFF) 3:Link Up (0.5s ON/0.5s OFF)
1.3.6.1.4.1.4756.20.680Nodef10G3RCards
1.3.6.1.4.1.4756.20.680.20Tablef10G3RTablenot-accessiblecurrentA list of local FRM220-10G-3R card entries. The number of entries is f10G3R-No-L.
1.3.6.1.4.1.4756.20.680.20.1Rowf10G3REntrynot-accessiblecurrentAn entry containing management information applicable to a particular local FRM220-10G-3R card.
1.3.6.1.4.1.4756.20.680.20.1.1Columnf10G3RChassisIndexread-onlycurrentA unique value for each local card. It is the chassis location number.
1.3.6.1.4.1.4756.20.680.20.1.2Columnf10G3RSlotIndexread-onlycurrentA unique value for each local card. It is the slot location number.
1.3.6.1.4.1.4756.20.680.20.1.3Columnf10G3RCardHWVerread-onlycurrentLocal FRM220-10G-3R card hardware version x.xxx
1.3.6.1.4.1.4756.20.680.20.1.4Columnf10G3RCardFWVerread-onlycurrentLocal FRM220-10G-3R card firmware version x.xxx
1.3.6.1.4.1.4756.20.680.20.1.5Columnf10G3RCardCPLDVerread-onlycurrentLocal FRM220-10G-3R card CPLD version x.xxx
1.3.6.1.4.1.4756.20.680.20.1.6Columnf10G3RCardFPGAVerread-onlycurrentLocal FRM220-10G-3R card FPGA version x.xxx
1.3.6.1.4.1.4756.20.680.20.1.7Columnf10G3RFx1Linkread-onlycurrentLocal FRM220-10G-3R card Fiber1 link status: 0:Down 1:Up
1.3.6.1.4.1.4756.20.680.20.1.8Columnf10G3RFx2Linkread-onlycurrentLocal FRM220-10G-3R card Fiber2 link status: 0:Down 1:Up
1.3.6.1.4.1.4756.20.680.20.1.9Columnf10G3RFx3Linkread-onlycurrentLocal FRM220-10G-3R card Fiber3 link status: 0:Down 1:Up
1.3.6.1.4.1.4756.20.680.20.1.10Columnf10G3RFx4Linkread-onlycurrentLocal FRM220-10G-3R card Fiber4 link status: 0:Down 1:Up
1.3.6.1.4.1.4756.20.680.20.1.11Columnf10G3RFx1CDRLockedread-onlycurrentLocal FRM220-10G-3R card Fiber1 CRD Locked: 0:Not Locked 1:Locked
1.3.6.1.4.1.4756.20.680.20.1.12Columnf10G3RFx2CDRLockedread-onlycurrentLocal FRM220-10G-3R card Fiber2 CRD Locked: 0:Not Locked 1:Locked
1.3.6.1.4.1.4756.20.680.20.1.13Columnf10G3RFx3CDRLockedread-onlycurrentLocal FRM220-10G-3R card Fiber3 CRD Locked: 0:Not Locked 1:Locked
1.3.6.1.4.1.4756.20.680.20.1.14Columnf10G3RFx4CDRLockedread-onlycurrentLocal FRM220-10G-3R card Fiber4 CRD Locked: 0:Not Locked 1:Locked
1.3.6.1.4.1.4756.20.680.20.1.15Columnf10G3RFx1TxFaultread-onlycurrentLocal FRM220-10G-3R card Fiber1 Tx Fault: 0:Normal 1:Failure
1.3.6.1.4.1.4756.20.680.20.1.16Columnf10G3RFx2TxFaultread-onlycurrentLocal FRM220-10G-3R card Fiber2 Tx Fault: 0:Normal 1:Failure
1.3.6.1.4.1.4756.20.680.20.1.17Columnf10G3RFx3TxFaultread-onlycurrentLocal FRM220-10G-3R card Fiber3 Tx Fault: 0:Normal 1:Failure
1.3.6.1.4.1.4756.20.680.20.1.18Columnf10G3RFx4TxFaultread-onlycurrentLocal FRM220-10G-3R card Fiber4 Tx Fault: 0:Normal 1:Failure
1.3.6.1.4.1.4756.20.680.20.1.19Columnf10G3RFx1DDread-onlycurrentLocal FRM220-10G-3R card fiber1 Digital Diagnostic function: 0:No 1:Yes
1.3.6.1.4.1.4756.20.680.20.1.20Columnf10G3RFx2DDread-onlycurrentLocal FRM220-10G-3R card fiber2 Digital Diagnostic function: 0:No 1:Yes
1.3.6.1.4.1.4756.20.680.20.1.21Columnf10G3RFx3DDread-onlycurrentLocal FRM220-10G-3R card fiber3 Digital Diagnostic function: 0:No 1:Yes
1.3.6.1.4.1.4756.20.680.20.1.22Columnf10G3RFx4DDread-onlycurrentLocal FRM220-10G-3R card fiber4 Digital Diagnostic function: 0:No 1:Yes
1.3.6.1.4.1.4756.20.680.20.1.23Columnf10G3RFx1DDStatusread-onlycurrentLocal FRM220-10G-3R card fiber1 D/D information: Status Support
1.3.6.1.4.1.4756.20.680.20.1.24Columnf10G3RFx2DDStatusread-onlycurrentLocal FRM220-10G-3R card fiber2 D/D information: Status Support
1.3.6.1.4.1.4756.20.680.20.1.25Columnf10G3RFx3DDStatusread-onlycurrentLocal FRM220-10G-3R card fiber3 D/D information: Status Support
1.3.6.1.4.1.4756.20.680.20.1.26Columnf10G3RFx4DDStatusread-onlycurrentLocal FRM220-10G-3R card fiber4 D/D information: Status Support
1.3.6.1.4.1.4756.20.680.20.1.27Columnf10G3RDeviceActiveread-writecurrentLocal FRM220-10G-3R card active: 0:Inactive 1:Active
1.3.6.1.4.1.4756.20.680.20.1.28Columnf10G3RPortResetread-writecurrentForce local FRM220-10G-3R card to reset mode: 0:Off 1:Action
1.3.6.1.4.1.4756.20.680.20.1.29Columnf10G3RSetDefaultread-writecurrentLocal FRM220-10G-3R card set to default : 0:Off 1:Action
1.3.6.1.4.1.4756.20.680.20.1.30Columnf10G3RWorkModeread-writecurrentLocal FRM220-10G-3R card Work Mode : 0:Protection 1:Dual Channel
1.3.6.1.4.1.4756.20.680.20.1.31Columnf10G3RFx1Lbsettingread-writecurrentLocal FRM220-10G-3R card Fiber1 Loopback: 0:Disable 1:Enable
1.3.6.1.4.1.4756.20.680.20.1.32Columnf10G3RFx2Lbsettingread-writecurrentLocal FRM220-10G-3R card Fiber2 Loopback: 0:Disable 1:Enable
1.3.6.1.4.1.4756.20.680.20.1.33Columnf10G3RFx3Lbsettingread-writecurrentLocal FRM220-10G-3R card Fiber3 Loopback: 0:Disable 1:Enable
1.3.6.1.4.1.4756.20.680.20.1.34Columnf10G3RFx4Lbsettingread-writecurrentLocal FRM220-10G-3R card Fiber4 Loopback: 0:Disable 1:Enable
1.3.6.1.4.1.4756.20.680.20.1.35Columnf10G3RFx1LFPTread-writecurrentLocal FRM220-10G-3R card Fiber1 Link Fault Pass Through: 0:Disable 1:Enable
1.3.6.1.4.1.4756.20.680.20.1.36Columnf10G3RFx2LFPTread-writecurrentLocal FRM220-10G-3R card Fiber2 Link Fault Pass Through: 0:Disable 1:Enable
1.3.6.1.4.1.4756.20.680.20.1.37Columnf10G3RFx3LFPTread-writecurrentLocal FRM220-10G-3R card Fiber3 Link Fault Pass Through: 0:Disable 1:Enable
1.3.6.1.4.1.4756.20.680.20.1.38Columnf10G3RFx4LFPTread-writecurrentLocal FRM220-10G-3R card Fiber4 Link Fault Pass Through: 0:Disable 1:Enable
1.3.6.1.4.1.4756.20.680.20.1.39Columnf10G3RFx1ALSModeread-writecurrentLocal FRM220-10G-3R card Fiber1 Auto Laser Showdown: 0:Disable 1:Enable
1.3.6.1.4.1.4756.20.680.20.1.40Columnf10G3RFx2ALSModeread-writecurrentLocal FRM220-10G-3R card Fiber2 Auto Laser Showdown: 0:Disable 1:Enable
1.3.6.1.4.1.4756.20.680.20.1.41Columnf10G3RFx3ALSModeread-writecurrentLocal FRM220-10G-3R card Fiber3 Auto Laser Showdown: 0:Disable 1:Enable
1.3.6.1.4.1.4756.20.680.20.1.42Columnf10G3RFx4ALSModeread-writecurrentLocal FRM220-10G-3R card Fiber4 Auto Laser Showdown: 0:Disable 1:Enable
1.3.6.1.4.1.4756.20.680.20.1.43Columnf10G3RFx1LinkAlarmread-writecurrentLocal FRM220-10G-3R card Fx1 Link Alarm: 0:Disalbe 1:Enable
1.3.6.1.4.1.4756.20.680.20.1.44Columnf10G3RFx2LinkAlarmread-writecurrentLocal FRM220-10G-3R card Fx2 Link Alarm: 0:Disalbe 1:Enable
1.3.6.1.4.1.4756.20.680.20.1.45Columnf10G3RFx3LinkAlarmread-writecurrentLocal FRM220-10G-3R card Fx3 Link Alarm: 0:Disalbe 1:Enable
1.3.6.1.4.1.4756.20.680.20.1.46Columnf10G3RFx4LinkAlarmread-writecurrentLocal FRM220-10G-3R card Fx4 Link Alarm: 0:Disalbe 1:Enable
1.3.6.1.4.1.4756.20.680.20.1.47Columnf10G3RSemiActiveread-writecurrentLocal FRM220-10G-3R card Semi-Active (Protection mode only): 0:Disalbe 1:Enable
1.3.6.1.4.1.4756.20.680.20.1.48Columnf10G3RWorkingPathStatusread-onlycurrentLocal FRM220-10G-3R card Workinng Path Status (Protection mode only): 0:Primary 1:Secondary
1.3.6.1.4.1.4756.20.680.20.1.49Columnf10G3RWorkingPathread-writecurrentLocal FRM220-10G-3R card Workinng Path(Protection mode only): 0:Auto-Revert 1:Non Revert 2:Primary 3:Secondary
1.3.6.1.4.1.4756.20.680.20.1.50Columnf10G3RDataRatelStatusread-onlycurrentLocal FRM220-10G-3R card Data Rate 1 Status:
1.3.6.1.4.1.4756.20.680.20.1.51Columnf10G3RDataRate2Statusread-onlycurrentLocal FRM220-10G-3R card Data Rate 2 Status(Dual Channel mode only):
1.3.6.1.4.1.4756.20.680.20.1.52Columnf10G3RProtocol1read-onlycurrentLocal FRM220-10G-3R card Protocol 1: 0:Ethernet 1:SONET/SDH 2:Fiber Channel 3:CPRI 4:OBSAI 5:OTU 6:ODU
1.3.6.1.4.1.4756.20.680.20.1.53Columnf10G3RRate1read-writecurrentLocal FRM220-10G-3R card Rate 1: Ethernet 0: 10GE 1: 1GE 2: 2500Base-X SONET/SDH 8: OC-192/STM-64 9: OC-48/STM-16 10:OC-24 11:OC-12/STM-4 Fiber Channel 16: 10G…
1.3.6.1.4.1.4756.20.680.20.1.54Columnf10G3RProtocol2read-onlycurrentLocal FRM220-10G-3R Protocol 2 (Dual Channel only): 0:Ethernet 1:SONET/SDH 2:Fiber Channel 3:CPRI 4:OBSAI 5:OTU 6:ODU
1.3.6.1.4.1.4756.20.680.20.1.55Columnf10G3RRate2read-writecurrentLocal FRM220-10G-3R card Rate2(Dual Channel only): Ethernet 0: 10GE 1: 1GE 2: 2500Base-X SONET/SDH 8: OC-192/STM-64 9: OC-48/STM-16 10:OC-24 11:OC-12/STM-4 Fib…
1.3.6.1.4.1.4756.20.680.20.1.56Columnf10G3RChannel1Activeread-writecurrentLocal FRM220-10G-3R card Channel 1 Active(Dual Channel only): 0:Disable 1:Enable
1.3.6.1.4.1.4756.20.680.20.1.57Columnf10G3RChannel2Activeread-writecurrentLocal FRM220-10G-3R card Channel 2 Active(Dual Channel only): 0:Disable 1:Enable
1.3.6.1.4.1.4756.20.680.20.1.58Columnf10G3RFx1DDVendorread-onlycurrentLocal FRM220-10G-3R card fiber1 D/D information: Vendor name
1.3.6.1.4.1.4756.20.680.20.1.59Columnf10G3RFx1DDPartNoread-onlycurrentLocal FRM220-10G-3R card fiber1 D/D information: Vendor part number
1.3.6.1.4.1.4756.20.680.20.1.60Columnf10G3RFx1DDVendorSNread-onlycurrentLocal FRM220-10G-3R card fiber1 D/D information: Vendor Serial number
1.3.6.1.4.1.4756.20.680.20.1.61Columnf10G3RFx1DDFiberTyperead-onlycurrentLocal FRM220-10G-3R card fiber1 D/D information: Fiber Type
1.3.6.1.4.1.4756.20.680.20.1.62Columnf10G3RFx1DDWaveLenread-onlycurrentLocal FRM220-10G-3R card fiber1 D/D information: Wave length
1.3.6.1.4.1.4756.20.680.20.1.63Columnf10G3RFx1DDWaveLen2read-onlycurrentLocal FRM220-10G-3R card fiber1 D/D information: Wave length 2
1.3.6.1.4.1.4756.20.680.20.1.64Columnf10G3RFx1DDLinkLenread-onlycurrentLocal FRM220-10G-3R card fiber1 D/D information: Link length
1.3.6.1.4.1.4756.20.680.20.1.65Columnf10G3RFx1DDLenUnitread-onlycurrentLocal FRM220-10G-3R card fiber1 D/D information: Length Unit
1.3.6.1.4.1.4756.20.680.20.1.66Columnf10G3RFx1DDRxSensread-onlycurrentLocal FRM220-10G-3R card fiber1 D/D information: Rx Sensitivity
1.3.6.1.4.1.4756.20.680.20.1.67Columnf10G3RFx1DDTxPWRread-onlycurrentLocal FRM220-10G-3R card fiber1 D/D information: Tx power
1.3.6.1.4.1.4756.20.680.20.1.68Columnf10G3RFx1DDRxPWRread-onlycurrentLocal FRM220-10G-3R card fiber1 D/D information: Rx power
1.3.6.1.4.1.4756.20.680.20.1.69Columnf10G3RFx1RxPowerStatusread-onlycurrentLocal FRM220-10G-3R card fiber1 Rx Power Status: 0:Normal 1:Warning 2:Alarm
1.3.6.1.4.1.4756.20.680.20.1.70Columnf10G3RFx1DDTempread-onlycurrentLocal FRM220-10G-3R card fiber1 D/D information: Temperature in degree C
1.3.6.1.4.1.4756.20.680.20.1.71Columnf10G3RFx1DDPWRMarginread-onlycurrentLocal FRM220-10G-3R card fiber1 D/D information: Power margin
1.3.6.1.4.1.4756.20.680.20.1.72Columnf10G3RFx2DDVendorread-onlycurrentLocal FRM220-10G-3R card fiber2 D/D information: Vendor name
1.3.6.1.4.1.4756.20.680.20.1.73Columnf10G3RFx2DDPartNoread-onlycurrentLocal FRM220-10G-3R card fiber2 D/D information: Vendor part number
1.3.6.1.4.1.4756.20.680.20.1.74Columnf10G3RFx2DDVendorSNread-onlycurrentLocal FRM220-10G-3R card fiber2 D/D information: Vendor Serial number
1.3.6.1.4.1.4756.20.680.20.1.75Columnf10G3RFx2DDFiberTyperead-onlycurrentLocal FRM220-10G-3R card fiber2 D/D information: Fiber Type
1.3.6.1.4.1.4756.20.680.20.1.76Columnf10G3RFx2DDWaveLenread-onlycurrentLocal FRM220-10G-3R card fiber2 D/D information: Wave length
1.3.6.1.4.1.4756.20.680.20.1.77Columnf10G3RFx2DDWaveLen2read-onlycurrentLocal FRM220-10G-3R card fiber2 D/D information: Wave length 2
1.3.6.1.4.1.4756.20.680.20.1.78Columnf10G3RFx2DDLinkLenread-onlycurrentLocal FRM220-10G-3R card fiber2 D/D information: Link length
1.3.6.1.4.1.4756.20.680.20.1.79Columnf10G3RFx2DDLenUnitread-onlycurrentLocal FRM220-10G-3R card fiber2 D/D information: Length Unit
1.3.6.1.4.1.4756.20.680.20.1.80Columnf10G3RFx2DDRxSensread-onlycurrentLocal FRM220-10G-3R card fiber2 D/D information: Rx Sensitivity
1.3.6.1.4.1.4756.20.680.20.1.81Columnf10G3RFx2DDTxPWRread-onlycurrentLocal FRM220-10G-3R card fiber2 D/D information: Tx power
1.3.6.1.4.1.4756.20.680.20.1.82Columnf10G3RFx2DDRxPWRread-onlycurrentLocal FRM220-10G-3R card fiber2 D/D information: Rx power
1.3.6.1.4.1.4756.20.680.20.1.83Columnf10G3RFx2RxPowerStatusread-onlycurrentLocal FRM220-10G-3R card fiber2 Rx Power Status: 0:Normal 1:Warning 2:Alarm
1.3.6.1.4.1.4756.20.680.20.1.84Columnf10G3RFx2DDTempread-onlycurrentLocal FRM220-10G-3R card fiber2 D/D information: Temperature in degree C
1.3.6.1.4.1.4756.20.680.20.1.85Columnf10G3RFx2DDPWRMarginread-onlycurrentLocal FRM220-10G-3R card fiber2 D/D information: Power margin
1.3.6.1.4.1.4756.20.680.20.1.86Columnf10G3RFx3DDVendorread-onlycurrentLocal FRM220-10G-3R card fiber3 D/D information: Vendor name
1.3.6.1.4.1.4756.20.680.20.1.87Columnf10G3RFx3DDPartNoread-onlycurrentLocal FRM220-10G-3R card fiber3 D/D information: Vendor part number
1.3.6.1.4.1.4756.20.680.20.1.88Columnf10G3RFx3DDVendorSNread-onlycurrentLocal FRM220-10G-3R card fiber3 D/D information: Vendor Serial number
1.3.6.1.4.1.4756.20.680.20.1.89Columnf10G3RFx3DDFiberTyperead-onlycurrentLocal FRM220-10G-3R card fiber3 D/D information: Fiber Type
1.3.6.1.4.1.4756.20.680.20.1.90Columnf10G3RFx3DDWaveLenread-onlycurrentLocal FRM220-10G-3R card fiber3 D/D information: Wave length
1.3.6.1.4.1.4756.20.680.20.1.91Columnf10G3RFx3DDWaveLen2read-onlycurrentLocal FRM220-10G-3R card fiber3 D/D information: Wave length 2
1.3.6.1.4.1.4756.20.680.20.1.92Columnf10G3RFx3DDLinkLenread-onlycurrentLocal FRM220-10G-3R card fiber3 D/D information: Link length
1.3.6.1.4.1.4756.20.680.20.1.93Columnf10G3RFx3DDLenUnitread-onlycurrentLocal FRM220-10G-3R card fiber3 D/D information: Length Unit
1.3.6.1.4.1.4756.20.680.20.1.94Columnf10G3RFx3DDRxSensread-onlycurrentLocal FRM220-10G-3R card fiber3 D/D information: Rx Sensitivity
1.3.6.1.4.1.4756.20.680.20.1.95Columnf10G3RFx3DDTxPWRread-onlycurrentLocal FRM220-10G-3R card fiber3 D/D information: Tx power
1.3.6.1.4.1.4756.20.680.20.1.96Columnf10G3RFx3DDRxPWRread-onlycurrentLocal FRM220-10G-3R card fiber3 D/D information: Rx power
1.3.6.1.4.1.4756.20.680.20.1.97Columnf10G3RFx3RxPowerStatusread-onlycurrentLocal FRM220-10G-3R card fiber3 Rx Power Status: 0:Normal 1:Warning 2:Alarm
1.3.6.1.4.1.4756.20.680.20.1.98Columnf10G3RFx3DDTempread-onlycurrentLocal FRM220-10G-3R card fiber3 D/D information: Temperature in degree C
1.3.6.1.4.1.4756.20.680.20.1.99Columnf10G3RFx3DDPWRMarginread-onlycurrentLocal FRM220-10G-3R card fiber3 D/D information: Power margin
1.3.6.1.4.1.4756.20.680.20.1.100Columnf10G3RFx4DDVendorread-onlycurrentLocal FRM220-10G-3R card fiber4 D/D information: Vendor name
1.3.6.1.4.1.4756.20.680.20.1.101Columnf10G3RFx4DDPartNoread-onlycurrentLocal FRM220-10G-3R card fiber4 D/D information: Vendor part number
1.3.6.1.4.1.4756.20.680.20.1.102Columnf10G3RFx4DDVendorSNread-onlycurrentLocal FRM220-10G-3R card fiber4 D/D information: Vendor Serial number
1.3.6.1.4.1.4756.20.680.20.1.103Columnf10G3RFx4DDFiberTyperead-onlycurrentLocal FRM220-10G-3R card fiber4 D/D information: Fiber Type
1.3.6.1.4.1.4756.20.680.20.1.104Columnf10G3RFx4DDWaveLenread-onlycurrentLocal FRM220-10G-3R card fiber4 D/D information: Wave length
1.3.6.1.4.1.4756.20.680.20.1.105Columnf10G3RFx4DDWaveLen2read-onlycurrentLocal FRM220-10G-3R card fiber4 D/D information: Wave length 2
1.3.6.1.4.1.4756.20.680.20.1.106Columnf10G3RFx4DDLinkLenread-onlycurrentLocal FRM220-10G-3R card fiber4 D/D information: Link length
1.3.6.1.4.1.4756.20.680.20.1.107Columnf10G3RFx4DDLenUnitread-onlycurrentLocal FRM220-10G-3R card fiber4 D/D information: Length Unit
1.3.6.1.4.1.4756.20.680.20.1.108Columnf10G3RFx4DDRxSensread-onlycurrentLocal FRM220-10G-3R card fiber4 D/D information: Rx Sensitivity
1.3.6.1.4.1.4756.20.680.20.1.109Columnf10G3RFx4DDTxPWRread-onlycurrentLocal FRM220-10G-3R card fiber4 D/D information: Tx power
1.3.6.1.4.1.4756.20.680.20.1.110Columnf10G3RFx4DDRxPWRread-onlycurrentLocal FRM220-10G-3R card fiber4 D/D information: Rx power
1.3.6.1.4.1.4756.20.680.20.1.111Columnf10G3RFx4RxPowerStatusread-onlycurrentLocal FRM220-10G-3R card fiber4 Rx Power Status: 0:Normal 1:Warning 2:Alarm
1.3.6.1.4.1.4756.20.680.20.1.112Columnf10G3RFx4DDTempread-onlycurrentLocal FRM220-10G-3R card fiber4 D/D information: Temperature in degree C
1.3.6.1.4.1.4756.20.680.20.1.113Columnf10G3RFx4DDPWRMarginread-onlycurrentLocal FRM220-10G-3R card fiber4 D/D information: Power margin
1.3.6.1.4.1.4756.20.680.20.1.114Columnf10G3RFx1RxPowerStatusAlarmread-writecurrentLocal FRM220-10G-3R card Line Rx Power Status trap. 0:Disable 1:Enable
1.3.6.1.4.1.4756.20.680.20.1.115Columnf10G3RFx1LosAssertAlarmread-writecurrentLocal FRM220-10G-3R card Line LOS Assert trap. 0:Disable 1:Enable
1.3.6.1.4.1.4756.20.680.20.1.116Columnf10G3RFx1RxPowerWarningThresholdread-writecurrentSet Line Rx Power Warning Threshold: Input range is from -60 to +10.
1.3.6.1.4.1.4756.20.680.20.1.117Columnf10G3RFx1RxPowerAlarmThresholdread-writecurrentSet Line Rx Power Alarm Threshold: Input range is from -60 to +10.
1.3.6.1.4.1.4756.20.680.20.1.118Columnf10G3RFx2RxPowerStatusAlarmread-writecurrentLocal FRM220-10G-3R card Primary Rx Power Status trap. 0:Disable 1:Enable
1.3.6.1.4.1.4756.20.680.20.1.119Columnf10G3RFx2LosAssertAlarmread-writecurrentLocal FRM220-10G-3R card Primary LOS Assert trap. 0:Disable 1:Enable
1.3.6.1.4.1.4756.20.680.20.1.120Columnf10G3RFx2RxPowerWarningThresholdread-writecurrentSet Primary Rx Power Warning Threshold: Input range is from -60 to +10.
1.3.6.1.4.1.4756.20.680.20.1.121Columnf10G3RFx2RxPowerAlarmThresholdread-writecurrentSet Primary Rx Power Alarm Threshold: Input range is from -60 to +10.
1.3.6.1.4.1.4756.20.680.20.1.122Columnf10G3RFx3RxPowerStatusAlarmread-writecurrentLocal FRM220-10G-3R card Secondary Rx Power Status trap. 0:Disable 1:Enable
1.3.6.1.4.1.4756.20.680.20.1.123Columnf10G3RFx3LosAssertAlarmread-writecurrentLocal FRM220-10G-3R card Secondary LOS Assert trap. 0:Disable 1:Enable
1.3.6.1.4.1.4756.20.680.20.1.124Columnf10G3RFx3RxPowerWarningThresholdread-writecurrentSet Secondary Rx Power Warning Threshold: Input range is from -60 to +10.
1.3.6.1.4.1.4756.20.680.20.1.125Columnf10G3RFx3RxPowerAlarmThresholdread-writecurrentSet Secondary Rx Power Alarm Threshold: Input range is from -60 to +10.
1.3.6.1.4.1.4756.20.680.20.1.126Columnf10G3RFx4RxPowerStatusAlarmread-writecurrentLocal FRM220-10G-3R card Fx4 Rx Power Status trap. 0:Disable 1:Enable
1.3.6.1.4.1.4756.20.680.20.1.127Columnf10G3RFx4LosAssertAlarmread-writecurrentLocal FRM220-10G-3R card Fx4 LOS Assert trap. 0:Disable 1:Enable
1.3.6.1.4.1.4756.20.680.20.1.128Columnf10G3RFx4RxPowerWarningThresholdread-writecurrentSet Secondary Rx Power Warning Threshold: Input range is from -60 to +10.
1.3.6.1.4.1.4756.20.680.20.1.129Columnf10G3RFx4RxPowerAlarmThresholdread-writecurrentSet Secondary Rx Power Alarm Threshold: Input range is from -60 to +10.
1.3.6.1.4.1.4756.20.680.20.1.130Columnf10G3RTemperatureread-onlycurrentLocal FRM220-10G-3R card temperature information: Temperature in degree C
1.3.6.1.4.1.4756.20.680.20.1.131Columnf10G3RPowerLedread-onlycurrentLocal FRM220-10G-3R card Powe Led. 0:ON (Power ON) 1:Flash (Standby; 1s ON/1s OFF)
1.3.6.1.4.1.4756.20.680.20.1.132Columnf10G3RSystemLedread-onlycurrentLocal FRM220-10G-3R card Syetem Led. 0:OFF(Fail) 1:ON (Normal)
1.3.6.1.4.1.4756.20.680.20.1.133Columnf10G3RModeLedread-onlycurrentLocal FRM220-10G-3R card Mode Led. 0:OFF(Dual Channel) 1:ON (Protection)
1.3.6.1.4.1.4756.20.680.20.1.134Columnf10G3RTestLedread-onlycurrentLocal FRM220-10G-3R card Test Led. 0:OFF(Normal) 1:ON (Test; Loopback Test)
1.3.6.1.4.1.4756.20.680.20.1.135Columnf10G3RFx1Ledread-onlycurrentLocal FRM220-10G-3R card Fx1 Led. 0:OFF(Link Down) 1:ON (SYNC) 2:LB (0.1s ON/0.1s OFF) 3:Link Up (0.5s ON/0.5s OFF)
1.3.6.1.4.1.4756.20.680.20.1.136Columnf10G3RFx2Ledread-onlycurrentLocal FRM220-10G-3R card Fx2 Led. 0:OFF(Link Down) 1:ON (SYNC) 2:LB (0.1s ON/0.1s OFF) 3:Link Up (0.5s ON/0.5s OFF) 4:Working Path (3s ON/0.2s OFF)
1.3.6.1.4.1.4756.20.680.20.1.137Columnf10G3RFx3Ledread-onlycurrentLocal FRM220-10G-3R card Fx3 Led. 0:OFF(Link Down) 1:ON (SYNC) 2:LB (0.1s ON/0.1s OFF) 3:Link Up (0.5s ON/0.5s OFF) 4:Working Path (3s ON/0.2s OFF)
1.3.6.1.4.1.4756.20.680.20.1.138Columnf10G3RFx4Ledread-onlycurrentLocal FRM220-10G-3R card Fx4 Led. 0:OFF(Link Down) 1:ON (SYNC) 2:LB (0.1s ON/0.1s OFF) 3:Link Up (0.5s ON/0.5s OFF)
1.3.6.1.4.1.4756.20.680.20.1.139Columnf10G3RTunableFx1chORfreqread-writecurrentLocal FRM220-10G-3R card Tunable Fiber 1 (CH1-1) chORfreq Mode. 0: Channel 1: Frequency
1.3.6.1.4.1.4756.20.680.20.1.140Columnf10G3RTunableFx2chORfreqread-writecurrentLocal FRM220-10G-3R card Tunable Fiber 2 (CH1-2) chORfreq Mode. 0: Channel 1: Frequency
1.3.6.1.4.1.4756.20.680.20.1.141Columnf10G3RTunableFx3chORfreqread-writecurrentLocal FRM220-10G-3R card Tunable Fiber 3 (CH2-3) chORfreq Mode. 0: Channel 1: Frequency
1.3.6.1.4.1.4756.20.680.20.1.142Columnf10G3RTunableFx4chORfreqread-writecurrentLocal FRM220-10G-3R card Tunable Fiber 4 (CH2-4) chORfreq Mode. 0: Channel 1: Frequency
1.3.6.1.4.1.4756.20.680.20.1.143Columnf10G3RTunableFx1Channelread-writecurrentLocal FRM220-10G-3R card Tunable Fiber 1 (CH1-1) Channel setting.
1.3.6.1.4.1.4756.20.680.20.1.144Columnf10G3RTunableFx2Channelread-writecurrentLocal FRM220-10G-3R card Tunable Fiber 2 (CH1-2) Channel setting.
1.3.6.1.4.1.4756.20.680.20.1.145Columnf10G3RTunableFx3Channelread-writecurrentLocal FRM220-10G-3R card Tunable Fiber 3 (CH2-3) Channel setting.
1.3.6.1.4.1.4756.20.680.20.1.146Columnf10G3RTunableFx4Channelread-writecurrentLocal FRM220-10G-3R card Tunable Fiber 4 (CH2-4) Channel setting.
1.3.6.1.4.1.4756.20.680.20.1.147Columnf10G3RFx1TempAlarmread-writecurrentLocal FRM220-10G-3R card Fiber 1 (CH1-1) over temperature alarm. 0: Disable 1: Enable 2: Not Support Tunable SFP
1.3.6.1.4.1.4756.20.680.20.1.148Columnf10G3RFx2TempAlarmread-writecurrentLocal FRM220-10G-3R card Fiber 2 (CH1-2) over temperature alarm. 0: Disable 1: Enable 2: Not Support Tunable SFP
1.3.6.1.4.1.4756.20.680.20.1.149Columnf10G3RFx3TempAlarmread-writecurrentLocal FRM220-10G-3R card Fiber 3 (CH2-3) over temperature alarm. 0: Disable 1: Enable 2: Not Support Tunable SFP
1.3.6.1.4.1.4756.20.680.20.1.150Columnf10G3RFx4TempAlarmread-writecurrentLocal FRM220-10G-3R card Fiber 4 (CH2-4) over temperature alarm. 0: Disable 1: Enable 2: Not Support Tunable SFP
1.3.6.1.4.1.4756.20.680.20.1.151Columnf10G3RTunableFx1Frequencyread-writecurrentLocal FRM220-10G-3R card Tunable Fiber 1 (CH1-1) Frequency setting.
1.3.6.1.4.1.4756.20.680.20.1.152Columnf10G3RTunableFx2Frequencyread-writecurrentLocal FRM220-10G-3R card Tunable Fiber 2 (CH1-2) Frequency setting.
1.3.6.1.4.1.4756.20.680.20.1.153Columnf10G3RTunableFx3Frequencyread-writecurrentLocal FRM220-10G-3R card Tunable Fiber 3 (CH2-3) Frequency setting.
1.3.6.1.4.1.4756.20.680.20.1.154Columnf10G3RTunableFx4Frequencyread-writecurrentLocal FRM220-10G-3R card Tunable Fiber 4 (CH2-4) Frequency setting.
1.3.6.1.4.1.4756.20.690Nodef40G2QCards
1.3.6.1.4.1.4756.20.690.20Tablef40G2QTablenot-accessiblecurrentA list of local FRM220-40G-2Q Line Card entries. The number of entries is f40G2Q-No-L.
1.3.6.1.4.1.4756.20.690.20.1Rowf40G2QEntrynot-accessiblecurrentAn entry containing management information applicable to a particular local FRM220-40G-2Q Line Card.
1.3.6.1.4.1.4756.20.690.20.1.1Columnf40G2QChassisIndexread-onlycurrentA unique value for each local card. It is the chassis location number.
1.3.6.1.4.1.4756.20.690.20.1.2Columnf40G2QSlotIndexread-onlycurrentA unique value for each local card. It is the slot location number.
1.3.6.1.4.1.4756.20.690.20.1.3Columnf40G2QCardHWVerread-onlycurrentLocal FRM220-40G-2Q Line Card hardware version x.xxx
1.3.6.1.4.1.4756.20.690.20.1.4Columnf40G2QCardFWVerread-onlycurrentLocal FRM220-40G-2Q Line Card firmware version x.xxx
1.3.6.1.4.1.4756.20.690.20.1.5Columnf40G2QCardCPLDVerread-onlycurrentLocal FRM220-40G-2Q Line Card CPLD version x.xxx
1.3.6.1.4.1.4756.20.690.20.1.6Columnf40G2QCardFPGAVerread-onlycurrentLocal FRM220-40G-2Q Line Card FPGA version x.xxx
1.3.6.1.4.1.4756.20.690.20.1.7Columnf40G2QPortResetread-writecurrentLocal FRM220-40G-2Q Line Card Port Reset feature: 0:Inactive 1:Active
1.3.6.1.4.1.4756.20.690.20.1.8Columnf40G2QSetDefaultread-writecurrentLocal FRM220-40G-2Q Line Card Set to Default function: 0:Inactive 1:Active
1.3.6.1.4.1.4756.20.690.20.1.9Columnf40G2QQSFP11Presentread-onlycurrentLocal FRM220-40G-2Q Line Card QSFP 1-1 Fiber Port Present: 0:NO 1:YES
1.3.6.1.4.1.4756.20.690.20.1.10Columnf40G2QQSFP12Presentread-onlycurrentLocal FRM220-40G-2Q Line Card QSFP 1-2 Fiber Port Present: 0:NO 1:YES
1.3.6.1.4.1.4756.20.690.20.1.11Columnf40G2QQSFP13Presentread-onlycurrentLocal FRM220-40G-2Q Line Card QSFP 1-3 Fiber Port Present: 0:NO 1:YES
1.3.6.1.4.1.4756.20.690.20.1.12Columnf40G2QQSFP14Presentread-onlycurrentLocal FRM220-40G-2Q Line Card QSFP 1-4 Fiber Port Present: 0:NO 1:YES
1.3.6.1.4.1.4756.20.690.20.1.13Columnf40G2QQSFP21Presentread-onlycurrentLocal FRM220-40G-2Q Line Card QSFP 2-1 Fiber Port Present: 0:NO 1:YES
1.3.6.1.4.1.4756.20.690.20.1.14Columnf40G2QQSFP22Presentread-onlycurrentLocal FRM220-40G-2Q Line Card QSFP 2-2 Fiber Port Present: 0:NO 1:YES
1.3.6.1.4.1.4756.20.690.20.1.15Columnf40G2QQSFP23Presentread-onlycurrentLocal FRM220-40G-2Q Line Card QSFP 2-3 Fiber Port Present: 0:NO 1:YES
1.3.6.1.4.1.4756.20.690.20.1.16Columnf40G2QQSFP24Presentread-onlycurrentLocal FRM220-40G-2Q Line Card QSFP 2-4 Fiber Port Present: 0:NO 1:YES
1.3.6.1.4.1.4756.20.690.20.1.17Columnf40G2QQSFP11DDMread-onlycurrentLocal FRM220-40G-2Q Line Card QSFP 1-1 Fiber Port Digital Diagnostic Monitoring (DDM): 0:NO 1:YES
1.3.6.1.4.1.4756.20.690.20.1.18Columnf40G2QQSFP12DDMread-onlycurrentLocal FRM220-40G-2Q Line Card QSFP 1-2 Fiber Port Digital Diagnostic Monitoring (DDM): 0:NO 1:YES
1.3.6.1.4.1.4756.20.690.20.1.19Columnf40G2QQSFP13DDMread-onlycurrentLocal FRM220-40G-2Q Line Card QSFP 1-3 Fiber Port Digital Diagnostic Monitoring (DDM): 0:NO 1:YES
1.3.6.1.4.1.4756.20.690.20.1.20Columnf40G2QQSFP14DDMread-onlycurrentLocal FRM220-40G-2Q Line Card QSFP 1-4 Fiber Port Digital Diagnostic Monitoring (DDM): 0:NO 1:YES
1.3.6.1.4.1.4756.20.690.20.1.21Columnf40G2QQSFP21DDMread-onlycurrentLocal FRM220-40G-2Q Line Card QSFP 2-1 Fiber Port Digital Diagnostic Monitoring (DDM): 0:NO 1:YES
1.3.6.1.4.1.4756.20.690.20.1.22Columnf40G2QQSFP22DDMread-onlycurrentLocal FRM220-40G-2Q Line Card QSFP 2-2 Fiber Port Digital Diagnostic Monitoring (DDM): 0:NO 1:YES
1.3.6.1.4.1.4756.20.690.20.1.23Columnf40G2QQSFP23DDMread-onlycurrentLocal FRM220-40G-2Q Line Card QSFP 2-3 Fiber Port Digital Diagnostic Monitoring (DDM): 0:NO 1:YES
1.3.6.1.4.1.4756.20.690.20.1.24Columnf40G2QQSFP24DDMread-onlycurrentLocal FRM220-40G-2Q Line Card QSFP 2-4 Fiber Port Digital Diagnostic Monitoring (DDM): 0:NO 1:YES
1.3.6.1.4.1.4756.20.690.20.1.25Columnf40G2QQSFP11Linkread-onlycurrentLocal FRM220-40G-2Q Line Card QSFP 1-1 Fiber Port Link Status: 0:Down 1:Up
1.3.6.1.4.1.4756.20.690.20.1.26Columnf40G2QQSFP12Linkread-onlycurrentLocal FRM220-40G-2Q Line Card QSFP 1-2 Fiber Port Link Status: 0:Down 1:Up
1.3.6.1.4.1.4756.20.690.20.1.27Columnf40G2QQSFP13Linkread-onlycurrentLocal FRM220-40G-2Q Line Card QSFP 1-3 Fiber Port Link Status: 0:Down 1:Up
1.3.6.1.4.1.4756.20.690.20.1.28Columnf40G2QQSFP14Linkread-onlycurrentLocal FRM220-40G-2Q Line Card QSFP 1-4 Fiber Port Link Status: 0:Down 1:Up
1.3.6.1.4.1.4756.20.690.20.1.29Columnf40G2QQSFP21Linkread-onlycurrentLocal FRM220-40G-2Q Line Card QSFP 2-1 Fiber Port Link Status: 0:Down 1:Up
1.3.6.1.4.1.4756.20.690.20.1.30Columnf40G2QQSFP22Linkread-onlycurrentLocal FRM220-40G-2Q Line Card QSFP 2-2 Fiber Port Link Status: 0:Down 1:Up
1.3.6.1.4.1.4756.20.690.20.1.31Columnf40G2QQSFP23Linkread-onlycurrentLocal FRM220-40G-2Q Line Card QSFP 2-3 Fiber Port Link Status: 0:Down 1:Up
1.3.6.1.4.1.4756.20.690.20.1.32Columnf40G2QQSFP24Linkread-onlycurrentLocal FRM220-40G-2Q Line Card QSFP 2-4 Fiber Port Link Status: 0:Down 1:Up
1.3.6.1.4.1.4756.20.690.20.1.33Columnf40G2QQSFP11CDRLockread-onlycurrentLocal FRM220-40G-2Q Line Card QSFP 1-1 Fiber Port CDR Lock Status: 0:Not Locked 1:Locked
1.3.6.1.4.1.4756.20.690.20.1.34Columnf40G2QQSFP12CDRLockread-onlycurrentLocal FRM220-40G-2Q Line Card QSFP 1-2 Fiber Port CDR Lock Status: 0:Not Locked 1:Locked
1.3.6.1.4.1.4756.20.690.20.1.35Columnf40G2QQSFP13CDRLockread-onlycurrentLocal FRM220-40G-2Q Line Card QSFP 1-3 Fiber Port CDR Lock Status: 0:Not Locked 1:Locked
1.3.6.1.4.1.4756.20.690.20.1.36Columnf40G2QQSFP14CDRLockread-onlycurrentLocal FRM220-40G-2Q Line Card QSFP 1-4 Fiber Port CDR Lock Status: 0:Not Locked 1:Locked
1.3.6.1.4.1.4756.20.690.20.1.37Columnf40G2QQSFP21CDRLockread-onlycurrentLocal FRM220-40G-2Q Line Card QSFP 2-1 Fiber Port CDR Lock Status: 0:Not Locked 1:Locked
1.3.6.1.4.1.4756.20.690.20.1.38Columnf40G2QQSFP22CDRLockread-onlycurrentLocal FRM220-40G-2Q Line Card QSFP 2-2 Fiber Port CDR Lock Status: 0:Not Locked 1:Locked
1.3.6.1.4.1.4756.20.690.20.1.39Columnf40G2QQSFP23CDRLockread-onlycurrentLocal FRM220-40G-2Q Line Card QSFP 2-3 Fiber Port CDR Lock Status: 0:Not Locked 1:Locked
1.3.6.1.4.1.4756.20.690.20.1.40Columnf40G2QQSFP24CDRLockread-onlycurrentLocal FRM220-40G-2Q Line Card QSFP 2-4 Fiber Port CDR Lock Status: 0:Not Locked 1:Locked
1.3.6.1.4.1.4756.20.690.20.1.41Columnf40G2QQSFP11TxFaultread-onlycurrentLocal FRM220-40G-2Q Line Card QSFP 1-1 Fiber Port Transmit Fault Status: 0:Normal 1:Failure
1.3.6.1.4.1.4756.20.690.20.1.42Columnf40G2QQSFP12TxFaultread-onlycurrentLocal FRM220-40G-2Q Line Card QSFP 1-2 Fiber Port Transmit Fault Status: 0:Normal 1:Failure
1.3.6.1.4.1.4756.20.690.20.1.43Columnf40G2QQSFP13TxFaultread-onlycurrentLocal FRM220-40G-2Q Line Card QSFP 1-3 Fiber Port Transmit Fault Status: 0:Normal 1:Failure
1.3.6.1.4.1.4756.20.690.20.1.44Columnf40G2QQSFP14TxFaultread-onlycurrentLocal FRM220-40G-2Q Line Card QSFP 1-4 Fiber Port Transmit Fault Status: 0:Normal 1:Failure
1.3.6.1.4.1.4756.20.690.20.1.45Columnf40G2QQSFP21TxFaultread-onlycurrentLocal FRM220-40G-2Q Line Card QSFP 2-1 Fiber Port Transmit Fault Status: 0:Normal 1:Failure
1.3.6.1.4.1.4756.20.690.20.1.46Columnf40G2QQSFP22TxFaultread-onlycurrentLocal FRM220-40G-2Q Line Card QSFP 2-2 Fiber Port Transmit Fault Status: 0:Normal 1:Failure
1.3.6.1.4.1.4756.20.690.20.1.47Columnf40G2QQSFP23TxFaultread-onlycurrentLocal FRM220-40G-2Q Line Card QSFP 2-3 Fiber Port Transmit Fault Status: 0:Normal 1:Failure
1.3.6.1.4.1.4756.20.690.20.1.48Columnf40G2QQSFP24TxFaultread-onlycurrentLocal FRM220-40G-2Q Line Card QSFP 2-4 Fiber Port Transmit Fault Status: 0:Normal 1:Failure
1.3.6.1.4.1.4756.20.690.20.1.49Columnf40G2QPortActiveread-writecurrentLocal FRM220-40G-2Q Line Card Active: 0:Disable 1:Enable
1.3.6.1.4.1.4756.20.690.20.1.50Columnf40G2QDataRateStsread-onlycurrentLocal FRM220-40G-2Q Line Card Data Rate Status.
1.3.6.1.4.1.4756.20.690.20.1.51Columnf40G2QDataRateread-writecurrentLocal FRM220-40G-2Q Line Card Data Rate setting: 0:Ethernet 10GE
1.3.6.1.4.1.4756.20.690.20.1.52Columnf40G2QQSFP1LBTread-writecurrentLocal FRM220-40G-2Q Line Card QSFP 1 LoopBack Test function setting: 0:Disable 1:Enable
1.3.6.1.4.1.4756.20.690.20.1.53Columnf40G2QQSFP2LBTread-writecurrentLocal FRM220-40G-2Q Line Card QSFP 2 LoopBack Test function setting: 0:Disable 1:Enable
1.3.6.1.4.1.4756.20.690.20.1.54Columnf40G2QQSFPLBTread-writecurrentLocal FRM220-40G-2Q Line Card both of QSFP 1 and QSFP 2 LoopBack Test function setting: 0:Disable 1:Enable
1.3.6.1.4.1.4756.20.690.20.1.55Columnf40G2QQSFP1LFPread-writecurrentLocal FRM220-40G-2Q Line Card QSFP 1 Link Fault Pass-Through setting: 0:Disable 1:Enable
1.3.6.1.4.1.4756.20.690.20.1.56Columnf40G2QQSFP11LFPread-writecurrentLocal FRM220-40G-2Q Line Card QSFP 1-1 Link Fault Pass-Through setting: 0:Disable 1:Enable
1.3.6.1.4.1.4756.20.690.20.1.57Columnf40G2QQSFP12LFPread-writecurrentLocal FRM220-40G-2Q Line Card QSFP 1-2 Link Fault Pass-Through setting: 0:Disable 1:Enable
1.3.6.1.4.1.4756.20.690.20.1.58Columnf40G2QQSFP13LFPread-writecurrentLocal FRM220-40G-2Q Line Card QSFP 1-3 Link Fault Pass-Through setting: 0:Disable 1:Enable
1.3.6.1.4.1.4756.20.690.20.1.59Columnf40G2QQSFP14LFPread-writecurrentLocal FRM220-40G-2Q Line Card QSFP 1-4 Link Fault Pass-Through setting: 0:Disable 1:Enable
1.3.6.1.4.1.4756.20.690.20.1.60Columnf40G2QQSFP2LFPread-writecurrentLocal FRM220-40G-2Q Line Card QSFP 2 Link Fault Pass-Through setting: 0:Disable 1:Enable
1.3.6.1.4.1.4756.20.690.20.1.61Columnf40G2QQSFP21LFPread-writecurrentLocal FRM220-40G-2Q Line Card QSFP 2-1 Link Fault Pass-Through setting: 0:Disable 1:Enable
1.3.6.1.4.1.4756.20.690.20.1.62Columnf40G2QQSFP22LFPread-writecurrentLocal FRM220-40G-2Q Line Card QSFP 2-2 Link Fault Pass-Through setting: 0:Disable 1:Enable
1.3.6.1.4.1.4756.20.690.20.1.63Columnf40G2QQSFP23LFPread-writecurrentLocal FRM220-40G-2Q Line Card QSFP 2-3 Link Fault Pass-Through setting: 0:Disable 1:Enable
1.3.6.1.4.1.4756.20.690.20.1.64Columnf40G2QQSFP24LFPread-writecurrentLocal FRM220-40G-2Q Line Card QSFP 2-4 Link Fault Pass-Through setting: 0:Disable 1:Enable
1.3.6.1.4.1.4756.20.690.20.1.65Columnf40G2QQSFP11LinkAlmread-writecurrentLocal FRM220-40G-2Q Line Card QSFP 1-1 Link Alarm setting: 0:Disable 1:Enable
1.3.6.1.4.1.4756.20.690.20.1.66Columnf40G2QQSFP12LinkAlmread-writecurrentLocal FRM220-40G-2Q Line Card QSFP 1-2 Link Alarm setting: 0:Disable 1:Enable
1.3.6.1.4.1.4756.20.690.20.1.67Columnf40G2QQSFP13LinkAlmread-writecurrentLocal FRM220-40G-2Q Line Card QSFP 1-3 Link Alarm setting: 0:Disable 1:Enable
1.3.6.1.4.1.4756.20.690.20.1.68Columnf40G2QQSFP14LinkAlmread-writecurrentLocal FRM220-40G-2Q Line Card QSFP 1-4 Link Alarm setting: 0:Disable 1:Enable
1.3.6.1.4.1.4756.20.690.20.1.69Columnf40G2QQSFP21LinkAlmread-writecurrentLocal FRM220-40G-2Q Line Card QSFP 2-1 Link Alarm setting: 0:Disable 1:Enable
1.3.6.1.4.1.4756.20.690.20.1.70Columnf40G2QQSFP22LinkAlmread-writecurrentLocal FRM220-40G-2Q Line Card QSFP 2-2 Link Alarm setting: 0:Disable 1:Enable
1.3.6.1.4.1.4756.20.690.20.1.71Columnf40G2QQSFP23LinkAlmread-writecurrentLocal FRM220-40G-2Q Line Card QSFP 2-3 Link Alarm setting: 0:Disable 1:Enable
1.3.6.1.4.1.4756.20.690.20.1.72Columnf40G2QQSFP24LinkAlmread-writecurrentLocal FRM220-40G-2Q Line Card QSFP 2-4 Link Alarm setting: 0:Disable 1:Enable
1.3.6.1.4.1.4756.20.690.20.1.73Columnf40G2QQSFP11LockAlmread-writecurrentLocal FRM220-40G-2Q Line Card QSFP 1-1 CDR Lock Alarm setting: 0:Disable 1:Enable
1.3.6.1.4.1.4756.20.690.20.1.74Columnf40G2QQSFP12LockAlmread-writecurrentLocal FRM220-40G-2Q Line Card QSFP 1-2 CDR Lock Alarm setting: 0:Disable 1:Enable
1.3.6.1.4.1.4756.20.690.20.1.75Columnf40G2QQSFP13LockAlmread-writecurrentLocal FRM220-40G-2Q Line Card QSFP 1-3 CDR Lock Alarm setting: 0:Disable 1:Enable
1.3.6.1.4.1.4756.20.690.20.1.76Columnf40G2QQSFP14LockAlmread-writecurrentLocal FRM220-40G-2Q Line Card QSFP 1-4 CDR Lock Alarm setting: 0:Disable 1:Enable
1.3.6.1.4.1.4756.20.690.20.1.77Columnf40G2QQSFP21LockAlmread-writecurrentLocal FRM220-40G-2Q Line Card QSFP 2-1 CDR Lock Alarm setting: 0:Disable 1:Enable
1.3.6.1.4.1.4756.20.690.20.1.78Columnf40G2QQSFP22LockAlmread-writecurrentLocal FRM220-40G-2Q Line Card QSFP 2-2 CDR Lock Alarm setting: 0:Disable 1:Enable
1.3.6.1.4.1.4756.20.690.20.1.79Columnf40G2QQSFP23LockAlmread-writecurrentLocal FRM220-40G-2Q Line Card QSFP 2-3 CDR Lock Alarm setting: 0:Disable 1:Enable
1.3.6.1.4.1.4756.20.690.20.1.80Columnf40G2QQSFP24LockAlmread-writecurrentLocal FRM220-40G-2Q Line Card QSFP 2-4 CDR Lock Alarm setting: 0:Disable 1:Enable
1.3.6.1.4.1.4756.20.690.20.1.81Columnf40G2QQSFP11TxFaultAlmread-writecurrentLocal FRM220-40G-2Q Line Card QSFP 1-1 Transmit Fault Alarm setting: 0:Disable 1:Enable
1.3.6.1.4.1.4756.20.690.20.1.82Columnf40G2QQSFP12TxFaultAlmread-writecurrentLocal FRM220-40G-2Q Line Card QSFP 1-2 Transmit Fault Alarm setting: 0:Disable 1:Enable
1.3.6.1.4.1.4756.20.690.20.1.83Columnf40G2QQSFP13TxFaultAlmread-writecurrentLocal FRM220-40G-2Q Line Card QSFP 1-3 Transmit Fault Alarm setting: 0:Disable 1:Enable
1.3.6.1.4.1.4756.20.690.20.1.84Columnf40G2QQSFP14TxFaultAlmread-writecurrentLocal FRM220-40G-2Q Line Card QSFP 1-4 Transmit Fault Alarm setting: 0:Disable 1:Enable
1.3.6.1.4.1.4756.20.690.20.1.85Columnf40G2QQSFP21TxFaultAlmread-writecurrentLocal FRM220-40G-2Q Line Card QSFP 2-1 Transmit Fault Alarm setting: 0:Disable 1:Enable
1.3.6.1.4.1.4756.20.690.20.1.86Columnf40G2QQSFP22TxFaultAlmread-writecurrentLocal FRM220-40G-2Q Line Card QSFP 2-2 Transmit Fault Alarm setting: 0:Disable 1:Enable
1.3.6.1.4.1.4756.20.690.20.1.87Columnf40G2QQSFP23TxFaultAlmread-writecurrentLocal FRM220-40G-2Q Line Card QSFP 2-3 Transmit Fault Alarm setting: 0:Disable 1:Enable
1.3.6.1.4.1.4756.20.690.20.1.88Columnf40G2QQSFP24TxFaultAlmread-writecurrentLocal FRM220-40G-2Q Line Card QSFP 2-4 Transmit Fault Alarm setting: 0:Disable 1:Enable
1.3.6.1.4.1.4756.20.690.20.1.89Columnf40G2QQSFP1VendorNameread-onlycurrentLocal FRM220-40G-2Q Line Card QSFP 1 Vender Name.
1.3.6.1.4.1.4756.20.690.20.1.90Columnf40G2QQSFP1PartNoread-onlycurrentLocal FRM220-40G-2Q Line Card QSFP 1 Part Number.
1.3.6.1.4.1.4756.20.690.20.1.91Columnf40G2QQSFP1OpticalTyperead-onlycurrentLocal FRM220-40G-2Q Line Card QSFP 1 Optical Type: 0:Multi 1:Single 2:Unknown 3:N/A
1.3.6.1.4.1.4756.20.690.20.1.92Columnf40G2QQSFP1WaveLength1read-onlycurrentLocal FRM220-40G-2Q Line Card QSFP 1 Wave Length 1.
1.3.6.1.4.1.4756.20.690.20.1.93Columnf40G2QQSFP1WaveLength2read-onlycurrentLocal FRM220-40G-2Q Line Card QSFP 1 Wave Length 2.
1.3.6.1.4.1.4756.20.690.20.1.94Columnf40G2QQSFP1LinkLengthread-onlycurrentLocal FRM220-40G-2Q Line Card QSFP 1 Link Length.
1.3.6.1.4.1.4756.20.690.20.1.95Columnf40G2QQSFP1Tempread-onlycurrentLocal FRM220-40G-2Q Line Card QSFP 1 Temperature.
1.3.6.1.4.1.4756.20.690.20.1.96Columnf40G2QQSFP1SupplyVolread-onlycurrentLocal FRM220-40G-2Q Line Card QSFP 1 Supply Voltage.
1.3.6.1.4.1.4756.20.690.20.1.97Columnf40G2QQSFP11TxPowerread-onlycurrentLocal FRM220-40G-2Q Line Card QSFP 1-1 Transmit Power.
1.3.6.1.4.1.4756.20.690.20.1.98Columnf40G2QQSFP11RxPowerread-onlycurrentLocal FRM220-40G-2Q Line Card QSFP 1-1 Receive Power.
1.3.6.1.4.1.4756.20.690.20.1.99Columnf40G2QQSFP11TxLaserBiasread-onlycurrentLocal FRM220-40G-2Q Line Card QSFP 1-1 Transmit Laser BIAS.
1.3.6.1.4.1.4756.20.690.20.1.100Columnf40G2QQSFP12TxPowerread-onlycurrentLocal FRM220-40G-2Q Line Card QSFP 1-2 Transmit Power.
1.3.6.1.4.1.4756.20.690.20.1.101Columnf40G2QQSFP12RxPowerread-onlycurrentLocal FRM220-40G-2Q Line Card QSFP 1-2 Receive Power.
1.3.6.1.4.1.4756.20.690.20.1.102Columnf40G2QQSFP12TxLaserBiasread-onlycurrentLocal FRM220-40G-2Q Line Card QSFP 1-2 Transmit Laser BIAS.
1.3.6.1.4.1.4756.20.690.20.1.103Columnf40G2QQSFP13TxPowerread-onlycurrentLocal FRM220-40G-2Q Line Card QSFP 1-3 Transmit Power.
1.3.6.1.4.1.4756.20.690.20.1.104Columnf40G2QQSFP13RxPowerread-onlycurrentLocal FRM220-40G-2Q Line Card QSFP 1-3 Receive Power.
1.3.6.1.4.1.4756.20.690.20.1.105Columnf40G2QQSFP13TxLaserBiasread-onlycurrentLocal FRM220-40G-2Q Line Card QSFP 1-3 Transmit Laser BIAS.
1.3.6.1.4.1.4756.20.690.20.1.106Columnf40G2QQSFP14TxPowerread-onlycurrentLocal FRM220-40G-2Q Line Card QSFP 1-4 Transmit Power.
1.3.6.1.4.1.4756.20.690.20.1.107Columnf40G2QQSFP14RxPowerread-onlycurrentLocal FRM220-40G-2Q Line Card QSFP 1-4 Receive Power.
1.3.6.1.4.1.4756.20.690.20.1.108Columnf40G2QQSFP14TxLaserBiasread-onlycurrentLocal FRM220-40G-2Q Line Card QSFP 1-4 Transmit Laser BIAS.
1.3.6.1.4.1.4756.20.690.20.1.109Columnf40G2QQSFP2VendorNameread-onlycurrentLocal FRM220-40G-2Q Line Card QSFP 2 Vender Name.
1.3.6.1.4.1.4756.20.690.20.1.110Columnf40G2QQSFP2PartNoread-onlycurrentLocal FRM220-40G-2Q Line Card QSFP 2 Part Number.
1.3.6.1.4.1.4756.20.690.20.1.111Columnf40G2QQSFP2OpticalTyperead-onlycurrentLocal FRM220-40G-2Q Line Card QSFP 2 Optical Type: 0:Multi 1:Single 2:Unknown 3:N/A
1.3.6.1.4.1.4756.20.690.20.1.112Columnf40G2QQSFP2WaveLength1read-onlycurrentLocal FRM220-40G-2Q Line Card QSFP 2 Wave Length 1.
1.3.6.1.4.1.4756.20.690.20.1.113Columnf40G2QQSFP2WaveLength2read-onlycurrentLocal FRM220-40G-2Q Line Card QSFP 2 Wave Length 2.
1.3.6.1.4.1.4756.20.690.20.1.114Columnf40G2QQSFP2LinkLengthread-onlycurrentLocal FRM220-40G-2Q Line Card QSFP 2 Link Length.
1.3.6.1.4.1.4756.20.690.20.1.115Columnf40G2QQSFP2Tempread-onlycurrentLocal FRM220-40G-2Q Line Card QSFP 2 Temperature.
1.3.6.1.4.1.4756.20.690.20.1.116Columnf40G2QQSFP2SupplyVolread-onlycurrentLocal FRM220-40G-2Q Line Card QSFP 2 Supply Voltage.
1.3.6.1.4.1.4756.20.690.20.1.117Columnf40G2QQSFP21TxPowerread-onlycurrentLocal FRM220-40G-2Q Line Card QSFP 2-1 Transmit Power.
1.3.6.1.4.1.4756.20.690.20.1.118Columnf40G2QQSFP21RxPowerread-onlycurrentLocal FRM220-40G-2Q Line Card QSFP 2-1 Receive Power.
1.3.6.1.4.1.4756.20.690.20.1.119Columnf40G2QQSFP21TxLaserBiasread-onlycurrentLocal FRM220-40G-2Q Line Card QSFP 2-1 Transmit Laser BIAS.
1.3.6.1.4.1.4756.20.690.20.1.120Columnf40G2QQSFP22TxPowerread-onlycurrentLocal FRM220-40G-2Q Line Card QSFP 2-2 Transmit Power.
1.3.6.1.4.1.4756.20.690.20.1.121Columnf40G2QQSFP22RxPowerread-onlycurrentLocal FRM220-40G-2Q Line Card QSFP 2-2 Receive Power.
1.3.6.1.4.1.4756.20.690.20.1.122Columnf40G2QQSFP22TxLaserBiasread-onlycurrentLocal FRM220-40G-2Q Line Card QSFP 2-2 Transmit Laser BIAS.
1.3.6.1.4.1.4756.20.690.20.1.123Columnf40G2QQSFP23TxPowerread-onlycurrentLocal FRM220-40G-2Q Line Card QSFP 2-3 Transmit Power.
1.3.6.1.4.1.4756.20.690.20.1.124Columnf40G2QQSFP23RxPowerread-onlycurrentLocal FRM220-40G-2Q Line Card QSFP 2-3 Receive Power.
1.3.6.1.4.1.4756.20.690.20.1.125Columnf40G2QQSFP23TxLaserBiasread-onlycurrentLocal FRM220-40G-2Q Line Card QSFP 2-3 Transmit Laser BIAS.
1.3.6.1.4.1.4756.20.690.20.1.126Columnf40G2QQSFP24TxPowerread-onlycurrentLocal FRM220-40G-2Q Line Card QSFP 2-4 Transmit Power.
1.3.6.1.4.1.4756.20.690.20.1.127Columnf40G2QQSFP24RxPowerread-onlycurrentLocal FRM220-40G-2Q Line Card QSFP 2-4 Receive Power.
1.3.6.1.4.1.4756.20.690.20.1.128Columnf40G2QQSFP24TxLaserBiasread-onlycurrentLocal FRM220-40G-2Q Line Card QSFP 2-4 Transmit Laser BIAS.
1.3.6.1.4.1.4756.20.700Nodef10GMUXLocalCards
1.3.6.1.4.1.4756.20.700.20Tablef10GMUXTablenot-accessiblecurrentA list of local FRM220-TM-10GMUX Line Card entries. The number of entries is f10GMUX-No-L.
1.3.6.1.4.1.4756.20.700.20.1Rowf10GMUXEntrynot-accessiblecurrentAn entry containing management information applicable to a particular local FRM220-TM-10GMUX Line Card.
1.3.6.1.4.1.4756.20.700.20.1.1Columnf10GMUXChassisIndexLocalread-onlycurrentA unique value for each local card. It is the chassis location number.
1.3.6.1.4.1.4756.20.700.20.1.2Columnf10GMUXSlotIndexLocalread-onlycurrentA unique value for each local card. It is the slot location number.
1.3.6.1.4.1.4756.20.700.20.1.3Columnf10GMUXCardHWVerLocalread-onlycurrentLocal FRM220-TM-10GMUX Line Card hardware version x.xxx
1.3.6.1.4.1.4756.20.700.20.1.4Columnf10GMUXCardFWVerLocalread-onlycurrentLocal FRM220-TM-10GMUX Line Card firmware version x.xxx
1.3.6.1.4.1.4756.20.700.20.1.5Columnf10GMUXCardCPLDVerLocalread-onlycurrentLocal FRM220-TM-10GMUX Line Card CPLD version x.xxx
1.3.6.1.4.1.4756.20.700.20.1.6Columnf10GMUXCardFPGAVerLocalread-onlycurrentLocal FRM220-TM-10GMUX Line Card FPGA version x.xxx
1.3.6.1.4.1.4756.20.700.20.1.7Columnf10GMUXPortResetLocalread-writecurrentLocal FRM220-TM-10GMUX card to reset mode: 0:Off 1:Action
1.3.6.1.4.1.4756.20.700.20.1.8Columnf10GMUXSetToDefaultLocalread-writecurrentLocal FRM220-TM-10GMUX card set to default : 0:Off 1:Action
1.3.6.1.4.1.4756.20.700.20.1.9Columnf10GMUXLineExistLocalread-onlycurrentLocal FRM220-TM-10GMUX card Line Exist status: 0:Empty 1:Exist
1.3.6.1.4.1.4756.20.700.20.1.10Columnf10GMUXCH1ExistLocalread-onlycurrentLocal FRM220-TM-10GMUX card CH1 Exist status: 0:Empty 1:Exist
1.3.6.1.4.1.4756.20.700.20.1.11Columnf10GMUXCH2ExistLocalread-onlycurrentLocal FRM220-TM-10GMUX card CH2 Exist status: 0:Empty 1:Exist
1.3.6.1.4.1.4756.20.700.20.1.12Columnf10GMUXCH3ExistLocalread-onlycurrentLocal FRM220-TM-10GMUX card CH3 Exist status: 0:Empty 1:Exist
1.3.6.1.4.1.4756.20.700.20.1.13Columnf10GMUXCH4ExistLocalread-onlycurrentLocal FRM220-TM-10GMUX card CH4 Exist status: 0:Empty 1:Exist
1.3.6.1.4.1.4756.20.700.20.1.14Columnf10GMUXCH5ExistLocalread-onlycurrentLocal FRM220-TM-10GMUX card CH5 Exist status: 0:Empty 1:Exist
1.3.6.1.4.1.4756.20.700.20.1.15Columnf10GMUXCH6ExistLocalread-onlycurrentLocal FRM220-TM-10GMUX card CH6 Exist status: 0:Empty 1:Exist
1.3.6.1.4.1.4756.20.700.20.1.16Columnf10GMUXCH7ExistLocalread-onlycurrentLocal FRM220-TM-10GMUX card CH7 Exist status: 0:Empty 1:Exist
1.3.6.1.4.1.4756.20.700.20.1.17Columnf10GMUXLineLinkLocalread-onlycurrentLocal FRM220-TM-10GMUX card Line Link status: 0:Down 1:up
1.3.6.1.4.1.4756.20.700.20.1.18Columnf10GMUXCH1LinkLocalread-onlycurrentLocal FRM220-TM-10GMUX card CH1 Link status: 0:Down 1:up
1.3.6.1.4.1.4756.20.700.20.1.19Columnf10GMUXCH2LinkLocalread-onlycurrentLocal FRM220-TM-10GMUX card CH2 Link status: 0:Down 1:up
1.3.6.1.4.1.4756.20.700.20.1.20Columnf10GMUXCH3LinkLocalread-onlycurrentLocal FRM220-TM-10GMUX card CH3 Link status: 0:Down 1:up
1.3.6.1.4.1.4756.20.700.20.1.21Columnf10GMUXCH4LinkLocalread-onlycurrentLocal FRM220-TM-10GMUX card CH4 Link status: 0:Down 1:up
1.3.6.1.4.1.4756.20.700.20.1.22Columnf10GMUXCH5LinkLocalread-onlycurrentLocal FRM220-TM-10GMUX card CH5 Link status: 0:Down 1:up
1.3.6.1.4.1.4756.20.700.20.1.23Columnf10GMUXCH6LinkLocalread-onlycurrentLocal FRM220-TM-10GMUX card CH6 Link status: 0:Down 1:up
1.3.6.1.4.1.4756.20.700.20.1.24Columnf10GMUXCH7LinkLocalread-onlycurrentLocal FRM220-TM-10GMUX card CH7 Link status: 0:Down 1:up
1.3.6.1.4.1.4756.20.700.20.1.25Columnf10GMUXLineSyncLocalread-onlycurrentLocal FRM220-TM-10GMUX card Line Sync status: 0:No 1:Yes
1.3.6.1.4.1.4756.20.700.20.1.26Columnf10GMUXCH1SyncLocalread-onlycurrentLocal FRM220-TM-10GMUX card CH1 Sync status: 0:No 1:Yes
1.3.6.1.4.1.4756.20.700.20.1.27Columnf10GMUXCH2SyncLocalread-onlycurrentLocal FRM220-TM-10GMUX card CH2 Sync status: 0:No 1:Yes
1.3.6.1.4.1.4756.20.700.20.1.28Columnf10GMUXCH3SyncLocalread-onlycurrentLocal FRM220-TM-10GMUX card CH3 Sync status: 0:No 1:Yes
1.3.6.1.4.1.4756.20.700.20.1.29Columnf10GMUXCH4SyncLocalread-onlycurrentLocal FRM220-TM-10GMUX card CH4 Sync status: 0:Not Locked 1:Yes
1.3.6.1.4.1.4756.20.700.20.1.30Columnf10GMUXCH5SyncLocalread-onlycurrentLocal FRM220-TM-10GMUX card CH5 Sync status: 0:No 1:Yes
1.3.6.1.4.1.4756.20.700.20.1.31Columnf10GMUXCH6SyncLocalread-onlycurrentLocal FRM220-TM-10GMUX card CH6 Sync status: 0:No 1:Yes
1.3.6.1.4.1.4756.20.700.20.1.32Columnf10GMUXCH7SyncLocalread-onlycurrentLocal FRM220-TM-10GMUX card CH7 Sync status: 0:no 1:yes
1.3.6.1.4.1.4756.20.700.20.1.33Columnf10GMUXLineTxFaultLocalread-onlycurrentLocal FRM220-TM-10GMUX card Line Tx Fault status: 0:Normal 1:Failure
1.3.6.1.4.1.4756.20.700.20.1.34Columnf10GMUXCH1TxFaultLocalread-onlycurrentLocal FRM220-TM-10GMUX card CH1 Tx Fault status: 0:Normal 1:Failure
1.3.6.1.4.1.4756.20.700.20.1.35Columnf10GMUXCH2TxFaultLocalread-onlycurrentLocal FRM220-TM-10GMUX card CH2 Tx Fault status: 0:Normal 1:Failure
1.3.6.1.4.1.4756.20.700.20.1.36Columnf10GMUXCH3TxFaultLocalread-onlycurrentLocal FRM220-TM-10GMUX card CH3 Tx Fault status: 0:Normal 1:Failure
1.3.6.1.4.1.4756.20.700.20.1.37Columnf10GMUXCH4TxFaultLocalread-onlycurrentLocal FRM220-TM-10GMUX card CH4 Tx Fault status: 0:Normal 1:Failure
1.3.6.1.4.1.4756.20.700.20.1.38Columnf10GMUXCH5TxFaultLocalread-onlycurrentLocal FRM220-TM-10GMUX card CH5 Tx Fault status: 0:Normal 1:Failure
1.3.6.1.4.1.4756.20.700.20.1.39Columnf10GMUXCH6TxFaultLocalread-onlycurrentLocal FRM220-TM-10GMUX card CH6 Tx Fault status: 0:Normal 1:Failure
1.3.6.1.4.1.4756.20.700.20.1.40Columnf10GMUXCH7TxFaultLocalread-onlycurrentLocal FRM220-TM-10GMUX card CH7 Tx Fault status: 0:Normal 1:Failure
1.3.6.1.4.1.4756.20.700.20.1.41Columnf10GMUXLineDDLocalread-onlycurrentLocal FRM220-TM-10GMUX card Line DD status: 0:no 1:yes
1.3.6.1.4.1.4756.20.700.20.1.42Columnf10GMUXCH1DDLocalread-onlycurrentLocal FRM220-TM-10GMUX card CH1 DD status: 0:no 1:yes
1.3.6.1.4.1.4756.20.700.20.1.43Columnf10GMUXCH2DDLocalread-onlycurrentLocal FRM220-TM-10GMUX card CH2 DD status: 0:no 1:yes
1.3.6.1.4.1.4756.20.700.20.1.44Columnf10GMUXCH3DDLocalread-onlycurrentLocal FRM220-TM-10GMUX card CH3 DD status: 0:no 1:yes
1.3.6.1.4.1.4756.20.700.20.1.45Columnf10GMUXCH4DDLocalread-onlycurrentLocal FRM220-TM-10GMUX card CH4 DD status: 0:no 1:yes
1.3.6.1.4.1.4756.20.700.20.1.46Columnf10GMUXCH5DDLocalread-onlycurrentLocal FRM220-TM-10GMUX card CH5 DD status: 0:no 1:yes
1.3.6.1.4.1.4756.20.700.20.1.47Columnf10GMUXCH6DDLocalread-onlycurrentLocal FRM220-TM-10GMUX card CH6 DD status: 0:no 1:yes
1.3.6.1.4.1.4756.20.700.20.1.48Columnf10GMUXCH7DDLocalread-onlycurrentLocal FRM220-TM-10GMUX card CH7 DD status: 0:no 1:yes
1.3.6.1.4.1.4756.20.700.20.1.49Columnf10GMUXLineCounterLocalread-onlycurrentFRM220-10GMUX cards Line Counter.
1.3.6.1.4.1.4756.20.700.20.1.50Columnf10GMUXCH1CounterLocalread-onlycurrentFRM220-10GMUX cards CH1 Counter.
1.3.6.1.4.1.4756.20.700.20.1.51Columnf10GMUXCH2CounterLocalread-onlycurrentFRM220-10GMUX cards CH2 Counter.
1.3.6.1.4.1.4756.20.700.20.1.52Columnf10GMUXCH3CounterLocalread-onlycurrentFRM220-10GMUX cards CH3 Counter.
1.3.6.1.4.1.4756.20.700.20.1.53Columnf10GMUXCH4CounterLocalread-onlycurrentFRM220-10GMUX cards CH4 Counter.
1.3.6.1.4.1.4756.20.700.20.1.54Columnf10GMUXCH5CounterLocalread-onlycurrentFRM220-10GMUX cards CH5 Counter.
1.3.6.1.4.1.4756.20.700.20.1.55Columnf10GMUXCH6CounterLocalread-onlycurrentFRM220-10GMUX cards CH6 Counter.
1.3.6.1.4.1.4756.20.700.20.1.56Columnf10GMUXCH7CounterLocalread-onlycurrentFRM220-10GMUX cards CH7 Counter.
1.3.6.1.4.1.4756.20.700.20.1.57Columnf10GMUXLinePortActiveLocalread-writecurrentFRM220-10GMUX cards Line Port Active: 0:disable 1:enable
1.3.6.1.4.1.4756.20.700.20.1.58Columnf10GMUXCH1PortActiveLocalread-writecurrentFRM220-10GMUX cards CH1 Port Active: 0:disable 1:enable
1.3.6.1.4.1.4756.20.700.20.1.59Columnf10GMUXCH2PortActiveLocalread-writecurrentFRM220-10GMUX cards CH2 Port Active: 0:disable 1:enable
1.3.6.1.4.1.4756.20.700.20.1.60Columnf10GMUXCH3PortActiveLocalread-writecurrentFRM220-10GMUX cards CH3 Port Active: 0:disable 1:enable
1.3.6.1.4.1.4756.20.700.20.1.61Columnf10GMUXCH4PortActiveLocalread-writecurrentFRM220-10GMUX cards CH4 Port Active: 0:disable 1:enable
1.3.6.1.4.1.4756.20.700.20.1.62Columnf10GMUXCH5PortActiveLocalread-writecurrentFRM220-10GMUX cards CH5 Port Active: 0:disable 1:enable
1.3.6.1.4.1.4756.20.700.20.1.63Columnf10GMUXCH6PortActiveLocalread-writecurrentFRM220-10GMUX cards CH6 Port Active: 0:disable 1:enable
1.3.6.1.4.1.4756.20.700.20.1.64Columnf10GMUXCH7PortActiveLocalread-writecurrentFRM220-10GMUX cards CH7 Port Active: 0:disable 1:enable
1.3.6.1.4.1.4756.20.700.20.1.65Columnf10GMUXLineLFPLocalread-writecurrentLocal FRM220-TM-10GMUX card Line Link Fault Pass Through: 0:Disable 1:Enable
1.3.6.1.4.1.4756.20.700.20.1.66Columnf10GMUXCH1LFPLocalread-writecurrentLocal FRM220-TM-10GMUX card CH1 Link Fault Pass Through: 0:Disable 1:Enable
1.3.6.1.4.1.4756.20.700.20.1.67Columnf10GMUXCH2LFPLocalread-writecurrentLocal FRM220-TM-10GMUX card CH2 Link Fault Pass Through: 0:Disable 1:Enable
1.3.6.1.4.1.4756.20.700.20.1.68Columnf10GMUXCH3LFPLocalread-writecurrentLocal FRM220-TM-10GMUX card CH3 Link Fault Pass Through: 0:Disable 1:Enable
1.3.6.1.4.1.4756.20.700.20.1.69Columnf10GMUXCH4LFPLocalread-writecurrentLocal FRM220-TM-10GMUX card CH4 Link Fault Pass Through: 0:Disable 1:Enable
1.3.6.1.4.1.4756.20.700.20.1.70Columnf10GMUXCH5LFPLocalread-writecurrentLocal FRM220-TM-10GMUX card CH5 Link Fault Pass Through: 0:Disable 1:Enable
1.3.6.1.4.1.4756.20.700.20.1.71Columnf10GMUXCH6LFPLocalread-writecurrentLocal FRM220-TM-10GMUX card CH6 Link Fault Pass Through: 0:Disable 1:Enable
1.3.6.1.4.1.4756.20.700.20.1.72Columnf10GMUXCH7LFPLocalread-writecurrentLocal FRM220-TM-10GMUX card CH7 Link Fault Pass Through: 0:Disable 1:Enable
1.3.6.1.4.1.4756.20.700.20.1.73Columnf10GMUXLineALSLocalread-writecurrentLocal FRM220-TM-10GMUX card Line Auto Laser Showdown: 0:Disable 1:Enable
1.3.6.1.4.1.4756.20.700.20.1.74Columnf10GMUXCH1ALSLocalread-writecurrentLocal FRM220-TM-10GMUX card CH1 Auto Laser Showdown: 0:Disable 1:Enable
1.3.6.1.4.1.4756.20.700.20.1.75Columnf10GMUXCH2ALSLocalread-writecurrentLocal FRM220-TM-10GMUX card CH2 Auto Laser Showdown: 0:Disable 1:Enable
1.3.6.1.4.1.4756.20.700.20.1.76Columnf10GMUXCH3ALSLocalread-writecurrentLocal FRM220-TM-10GMUX card CH3 Auto Laser Showdown: 0:Disable 1:Enable
1.3.6.1.4.1.4756.20.700.20.1.77Columnf10GMUXCH4ALSLocalread-writecurrentLocal FRM220-TM-10GMUX card CH4 Auto Laser Showdown: 0:Disable 1:Enable
1.3.6.1.4.1.4756.20.700.20.1.78Columnf10GMUXCH5ALSLocalread-writecurrentLocal FRM220-TM-10GMUX card CH5 Auto Laser Showdown: 0:Disable 1:Enable
1.3.6.1.4.1.4756.20.700.20.1.79Columnf10GMUXCH6ALSLocalread-writecurrentLocal FRM220-TM-10GMUX card CH6 Auto Laser Showdown: 0:Disable 1:Enable
1.3.6.1.4.1.4756.20.700.20.1.80Columnf10GMUXCH7ALSLocalread-writecurrentLocal FRM220-TM-10GMUX card CH7 Auto Laser Showdown: 0:Disable 1:Enable
1.3.6.1.4.1.4756.20.700.20.1.81Columnf10GMUXCH1LoopbackLocalread-writecurrentLocal FRM220-TM-10GMUX card CH1 Loopback: 0:Disable 1:Enable
1.3.6.1.4.1.4756.20.700.20.1.82Columnf10GMUXCH2LoopbackLocalread-writecurrentLocal FRM220-TM-10GMUX card CH2 Loopback: 0:Disable 1:Enable
1.3.6.1.4.1.4756.20.700.20.1.83Columnf10GMUXCH3LoopbackLocalread-writecurrentLocal FRM220-TM-10GMUX card CH3 Loopback: 0:Disable 1:Enable
1.3.6.1.4.1.4756.20.700.20.1.84Columnf10GMUXCH4LoopbackLocalread-writecurrentLocal FRM220-TM-10GMUX card CH4 Loopback: 0:Disable 1:Enable
1.3.6.1.4.1.4756.20.700.20.1.85Columnf10GMUXCH5LoopbackLocalread-writecurrentLocal FRM220-TM-10GMUX card CH5 Loopback: 0:Disable 1:Enable
1.3.6.1.4.1.4756.20.700.20.1.86Columnf10GMUXCH6LoopbackLocalread-writecurrentLocal FRM220-TM-10GMUX card CH6 Loopback: 0:Disable 1:Enable
1.3.6.1.4.1.4756.20.700.20.1.87Columnf10GMUXCH7LoopbackLocalread-writecurrentLocal FRM220-TM-10GMUX card CH7 Loopback: 0:Disable 1:Enable
1.3.6.1.4.1.4756.20.700.20.1.88Columnf10GMUXAlarmStatusLocalread-onlycurrentLocal FRM220-TM-10GMUX card Alarm status: 0:Normal 1:Abmormal
1.3.6.1.4.1.4756.20.700.20.1.89Columnf10GMUXLineTriggerLocalread-writecurrentFRM220-10GMUX cards Line Trigger: 0:disable 1:enable
1.3.6.1.4.1.4756.20.700.20.1.90Columnf10GMUXCH1TriggerLocalread-writecurrentFRM220-10GMUX cards CH1 Trigger: 0:disable 1:enable
1.3.6.1.4.1.4756.20.700.20.1.91Columnf10GMUXCH2TriggerLocalread-writecurrentFRM220-10GMUX cards CH2 Trigger: 0:disable 1:enable
1.3.6.1.4.1.4756.20.700.20.1.92Columnf10GMUXCH3TriggerLocalread-writecurrentFRM220-10GMUX cards CH3 Trigger: 0:disable 1:enable
1.3.6.1.4.1.4756.20.700.20.1.93Columnf10GMUXCH4TriggerLocalread-writecurrentFRM220-10GMUX cards CH4 Trigger: 0:disable 1:enable
1.3.6.1.4.1.4756.20.700.20.1.94Columnf10GMUXCH5TriggerLocalread-writecurrentFRM220-10GMUX cards CH5 Trigger: 0:disable 1:enable
1.3.6.1.4.1.4756.20.700.20.1.95Columnf10GMUXCH6TriggerLocalread-writecurrentFRM220-10GMUX cards CH6 Trigger: 0:disable 1:enable
1.3.6.1.4.1.4756.20.700.20.1.96Columnf10GMUXCH7TriggerLocalread-writecurrentFRM220-10GMUX cards CH7 Trigger: 0:disable 1:enable
1.3.6.1.4.1.4756.20.700.20.1.97Columnf10GMUXLineDDVendorLocalread-onlycurrentLocal FRM220-TM-10GMUX card Line D/D information: Vendor name
1.3.6.1.4.1.4756.20.700.20.1.98Columnf10GMUXLineDDPartNoLocalread-onlycurrentLocal FRM220-TM-10GMUX card Line D/D information: Vendor part number
1.3.6.1.4.1.4756.20.700.20.1.99Columnf10GMUXLineDDVendorSNLocalread-onlycurrentLocal FRM220-TM-10GMUX card Line D/D information: Vendor SN
1.3.6.1.4.1.4756.20.700.20.1.100Columnf10GMUXLineDDFiberTypeLocalread-onlycurrentLocal FRM220-TM-10GMUX card Line D/D information: Fiber Type
1.3.6.1.4.1.4756.20.700.20.1.101Columnf10GMUXLineDDWaveLenLocalread-onlycurrentLocal FRM220-TM-10GMUX card Line D/D information: Wave length
1.3.6.1.4.1.4756.20.700.20.1.102Columnf10GMUXLineDDWaveLen2Localread-onlycurrentLocal FRM220-TM-10GMUX card Line D/D information: Wave length 2
1.3.6.1.4.1.4756.20.700.20.1.103Columnf10GMUXLineDDLinkLenLocalread-onlycurrentLocal FRM220-TM-10GMUX card Line D/D information: Link length
1.3.6.1.4.1.4756.20.700.20.1.104Columnf10GMUXLineDDLenUnitLocalread-onlycurrentLocal FRM220-10GMUX card Line D/D information: Length Unit
1.3.6.1.4.1.4756.20.700.20.1.105Columnf10GMUXLineDDRxSensLocalread-onlycurrentLocal FRM220-TM-10GMUX card Line D/D information: Rx Sensitivity
1.3.6.1.4.1.4756.20.700.20.1.106Columnf10GMUXLineDDTxPWRLocalread-onlycurrentLocal FRM220-TM-10GMUX card Line D/D information: Tx power
1.3.6.1.4.1.4756.20.700.20.1.107Columnf10GMUXLineDDRxPWRLocalread-onlycurrentLocal FRM220-TM-10GMUX card Line D/D information: Rx power
1.3.6.1.4.1.4756.20.700.20.1.108Columnf10GMUXLineDDTempLocalread-onlycurrentLocal FRM220-TM-10GMUX card Line D/D information: Temperature in degree C
1.3.6.1.4.1.4756.20.700.20.1.109Columnf10GMUXLineSupplyVolLocalread-onlycurrentLocal FRM220-TM-10GMUX card Line D/D information: SupplyVol
1.3.6.1.4.1.4756.20.700.20.1.110Columnf10GMUXLineTxLaserBiasLocalread-onlycurrentLocal FRM220-TM-10GMUX card Line D/D information: Tx LaserBias
1.3.6.1.4.1.4756.20.700.20.1.111Columnf10GMUXCH1DDVendorLocalread-onlycurrentLocal FRM220-TM-10GMUX card CH1 D/D information: Vendor name
1.3.6.1.4.1.4756.20.700.20.1.112Columnf10GMUXCH1DDPartNoLocalread-onlycurrentLocal FRM220-TM-10GMUX card CH1 D/D information: Vendor part number
1.3.6.1.4.1.4756.20.700.20.1.113Columnf10GMUXCH1DDVendorSNLocalread-onlycurrentLocal FRM220-TM-10GMUX card CH1 D/D information: Vendor SN
1.3.6.1.4.1.4756.20.700.20.1.114Columnf10GMUXCH1DDFiberTypeLocalread-onlycurrentLocal FRM220-TM-10GMUX card CH1 D/D information: Fiber Type
1.3.6.1.4.1.4756.20.700.20.1.115Columnf10GMUXCH1DDWaveLenLocalread-onlycurrentLocal FRM220-TM-10GMUX card CH1 D/D information: Wave length
1.3.6.1.4.1.4756.20.700.20.1.116Columnf10GMUXCH1DDWaveLen2Localread-onlycurrentLocal FRM220-TM-10GMUX card CH1 D/D information: Wave length 2
1.3.6.1.4.1.4756.20.700.20.1.117Columnf10GMUXCH1DDLinkLenLocalread-onlycurrentLocal FRM220-TM-10GMUX card CH1 D/D information: Link length
1.3.6.1.4.1.4756.20.700.20.1.118Columnf10GMUXCH1DDLenUnitLocalread-onlycurrentLocal FRM220-10GMUX card CH1 D/D information: Length Unit
1.3.6.1.4.1.4756.20.700.20.1.119Columnf10GMUXCH1DDRxSensLocalread-onlycurrentLocal FRM220-TM-10GMUX card CH1 D/D information: Rx Sensitivity
1.3.6.1.4.1.4756.20.700.20.1.120Columnf10GMUXCH1DDTxPWRLocalread-onlycurrentLocal FRM220-TM-10GMUX card CH1 D/D information: Tx power
1.3.6.1.4.1.4756.20.700.20.1.121Columnf10GMUXCH1DDRxPWRLocalread-onlycurrentLocal FRM220-TM-10GMUX card CH1 D/D information: Rx power
1.3.6.1.4.1.4756.20.700.20.1.122Columnf10GMUXCH1DDTempLocalread-onlycurrentLocal FRM220-TM-10GMUX card CH1 D/D information: Temperature in degree C
1.3.6.1.4.1.4756.20.700.20.1.123Columnf10GMUXCH1SupplyVolLocalread-onlycurrentLocal FRM220-TM-10GMUX card CH1 D/D information: SupplyVol
1.3.6.1.4.1.4756.20.700.20.1.124Columnf10GMUXCH1TxLaserBiasLocalread-onlycurrentLocal FRM220-TM-10GMUX card CH1 D/D information: Tx LaserBias
1.3.6.1.4.1.4756.20.700.20.1.125Columnf10GMUXCH2DDVendorLocalread-onlycurrentLocal FRM220-TM-10GMUX card CH2 D/D information: Vendor name
1.3.6.1.4.1.4756.20.700.20.1.126Columnf10GMUXCH2DDPartNoLocalread-onlycurrentLocal FRM220-TM-10GMUX card CH2 D/D information: Vendor part number
1.3.6.1.4.1.4756.20.700.20.1.127Columnf10GMUXCH2DDVendorSNLocalread-onlycurrentLocal FRM220-TM-10GMUX card CH2 D/D information: Vendor SN
1.3.6.1.4.1.4756.20.700.20.1.128Columnf10GMUXCH2DDFiberTypeLocalread-onlycurrentLocal FRM220-TM-10GMUX card CH2 D/D information: Fiber Type
1.3.6.1.4.1.4756.20.700.20.1.129Columnf10GMUXCH2DDWaveLenLocalread-onlycurrentLocal FRM220-TM-10GMUX card CH2 D/D information: Wave length
1.3.6.1.4.1.4756.20.700.20.1.130Columnf10GMUXCH2DDWaveLen2Localread-onlycurrentLocal FRM220-TM-10GMUX card CH2 D/D information: Wave length 2
1.3.6.1.4.1.4756.20.700.20.1.131Columnf10GMUXCH2DDLinkLenLocalread-onlycurrentLocal FRM220-TM-10GMUX card CH2 D/D information: Link length
1.3.6.1.4.1.4756.20.700.20.1.132Columnf10GMUXCH2DDLenUnitLocalread-onlycurrentLocal FRM220-10GMUX card CH2 D/D information: Length Unit
1.3.6.1.4.1.4756.20.700.20.1.133Columnf10GMUXCH2DDRxSensLocalread-onlycurrentLocal FRM220-TM-10GMUX card CH2 D/D information: Rx Sensitivity
1.3.6.1.4.1.4756.20.700.20.1.134Columnf10GMUXCH2DDTxPWRLocalread-onlycurrentLocal FRM220-TM-10GMUX card CH2 D/D information: Tx power
1.3.6.1.4.1.4756.20.700.20.1.135Columnf10GMUXCH2DDRxPWRLocalread-onlycurrentLocal FRM220-TM-10GMUX card CH2 D/D information: Rx power
1.3.6.1.4.1.4756.20.700.20.1.136Columnf10GMUXCH2DDTempLocalread-onlycurrentLocal FRM220-TM-10GMUX card CH2 D/D information: Temperature in degree C
1.3.6.1.4.1.4756.20.700.20.1.137Columnf10GMUXCH2SupplyVolLocalread-onlycurrentLocal FRM220-TM-10GMUX card CH2 D/D information: SupplyVol
1.3.6.1.4.1.4756.20.700.20.1.138Columnf10GMUXCH2TxLaserBiasLocalread-onlycurrentLocal FRM220-TM-10GMUX card CH2 D/D information: Tx LaserBias
1.3.6.1.4.1.4756.20.700.20.1.139Columnf10GMUXCH3DDVendorLocalread-onlycurrentLocal FRM220-TM-10GMUX card CH3 D/D information: Vendor name
1.3.6.1.4.1.4756.20.700.20.1.140Columnf10GMUXCH3DDPartNoLocalread-onlycurrentLocal FRM220-TM-10GMUX card CH3 D/D information: Vendor part number
1.3.6.1.4.1.4756.20.700.20.1.141Columnf10GMUXCH3DDVendorSNLocalread-onlycurrentLocal FRM220-TM-10GMUX card CH3 D/D information: Vendor SN
1.3.6.1.4.1.4756.20.700.20.1.142Columnf10GMUXCH3DDFiberTypeLocalread-onlycurrentLocal FRM220-TM-10GMUX card CH3 D/D information: Fiber Type
1.3.6.1.4.1.4756.20.700.20.1.143Columnf10GMUXCH3DDWaveLenLocalread-onlycurrentLocal FRM220-TM-10GMUX card CH3 D/D information: Wave length
1.3.6.1.4.1.4756.20.700.20.1.144Columnf10GMUXCH3DDWaveLen2Localread-onlycurrentLocal FRM220-TM-10GMUX card CH3 D/D information: Wave length 2
1.3.6.1.4.1.4756.20.700.20.1.145Columnf10GMUXCH3DDLinkLenLocalread-onlycurrentLocal FRM220-TM-10GMUX card CH3 D/D information: Link length
1.3.6.1.4.1.4756.20.700.20.1.146Columnf10GMUXCH3DDLenUnitLocalread-onlycurrentLocal FRM220-10GMUX card CH3 D/D information: Length Unit
1.3.6.1.4.1.4756.20.700.20.1.147Columnf10GMUXCH3DDRxSensLocalread-onlycurrentLocal FRM220-TM-10GMUX card CH3 D/D information: Rx Sensitivity
1.3.6.1.4.1.4756.20.700.20.1.148Columnf10GMUXCH3DDTxPWRLocalread-onlycurrentLocal FRM220-TM-10GMUX card CH3 D/D information: Tx power
1.3.6.1.4.1.4756.20.700.20.1.149Columnf10GMUXCH3DDRxPWRLocalread-onlycurrentLocal FRM220-TM-10GMUX card CH3 D/D information: Rx power
1.3.6.1.4.1.4756.20.700.20.1.150Columnf10GMUXCH3DDTempLocalread-onlycurrentLocal FRM220-TM-10GMUX card CH3 D/D information: Temperature in degree C
1.3.6.1.4.1.4756.20.700.20.1.151Columnf10GMUXCH3SupplyVolLocalread-onlycurrentLocal FRM220-TM-10GMUX card CH3 D/D information: SupplyVol
1.3.6.1.4.1.4756.20.700.20.1.152Columnf10GMUXCH3TxLaserBiasLocalread-onlycurrentLocal FRM220-TM-10GMUX card CH3 D/D information: Tx LaserBias
1.3.6.1.4.1.4756.20.700.20.1.153Columnf10GMUXCH4DDVendorLocalread-onlycurrentLocal FRM220-TM-10GMUX card CH4 D/D information: Vendor name
1.3.6.1.4.1.4756.20.700.20.1.154Columnf10GMUXCH4DDPartNoLocalread-onlycurrentLocal FRM220-TM-10GMUX card CH4 D/D information: Vendor part number
1.3.6.1.4.1.4756.20.700.20.1.155Columnf10GMUXCH4DDVendorSNLocalread-onlycurrentLocal FRM220-TM-10GMUX card CH4 D/D information: Vendor SN
1.3.6.1.4.1.4756.20.700.20.1.156Columnf10GMUXCH4DDFiberTypeLocalread-onlycurrentLocal FRM220-TM-10GMUX card CH4 D/D information: Fiber Type
1.3.6.1.4.1.4756.20.700.20.1.157Columnf10GMUXCH4DDWaveLenLocalread-onlycurrentLocal FRM220-TM-10GMUX card CH4 D/D information: Wave length
1.3.6.1.4.1.4756.20.700.20.1.158Columnf10GMUXCH4DDWaveLen2Localread-onlycurrentLocal FRM220-TM-10GMUX card CH4 D/D information: Wave length 2
1.3.6.1.4.1.4756.20.700.20.1.159Columnf10GMUXCH4DDLinkLenLocalread-onlycurrentLocal FRM220-TM-10GMUX card CH4 D/D information: Link length
1.3.6.1.4.1.4756.20.700.20.1.160Columnf10GMUXCH4DDRxSensLocalread-onlycurrentLocal FRM220-TM-10GMUX card CH4 D/D information: Rx Sensitivity
1.3.6.1.4.1.4756.20.700.20.1.161Columnf10GMUXCH4DDLenUnitLocalread-onlycurrentLocal FRM220-10GMUX card CH4 D/D information: Length Unit
1.3.6.1.4.1.4756.20.700.20.1.162Columnf10GMUXCH4DDTxPWRLocalread-onlycurrentLocal FRM220-TM-10GMUX card CH4 D/D information: Tx power
1.3.6.1.4.1.4756.20.700.20.1.163Columnf10GMUXCH4DDRxPWRLocalread-onlycurrentLocal FRM220-TM-10GMUX card CH4 D/D information: Rx power
1.3.6.1.4.1.4756.20.700.20.1.164Columnf10GMUXCH4DDTempLocalread-onlycurrentLocal FRM220-TM-10GMUX card CH4 D/D information: Temperature in degree C
1.3.6.1.4.1.4756.20.700.20.1.165Columnf10GMUXCH4SupplyVolLocalread-onlycurrentLocal FRM220-TM-10GMUX card CH4 D/D information: SupplyVol
1.3.6.1.4.1.4756.20.700.20.1.166Columnf10GMUXCH4TxLaserBiasLocalread-onlycurrentLocal FRM220-TM-10GMUX card CH4 D/D information: Tx LaserBias
1.3.6.1.4.1.4756.20.700.20.1.167Columnf10GMUXCH5DDVendorLocalread-onlycurrentLocal FRM220-TM-10GMUX card CH5 D/D information: Vendor name
1.3.6.1.4.1.4756.20.700.20.1.168Columnf10GMUXCH5DDPartNoLocalread-onlycurrentLocal FRM220-TM-10GMUX card CH5 D/D information: Vendor part number
1.3.6.1.4.1.4756.20.700.20.1.169Columnf10GMUXCH5DDVendorSNLocalread-onlycurrentLocal FRM220-TM-10GMUX card CH5 D/D information: Vendor SN
1.3.6.1.4.1.4756.20.700.20.1.170Columnf10GMUXCH5DDFiberTypeLocalread-onlycurrentLocal FRM220-TM-10GMUX card CH5 D/D information: Fiber Type
1.3.6.1.4.1.4756.20.700.20.1.171Columnf10GMUXCH5DDWaveLenLocalread-onlycurrentLocal FRM220-TM-10GMUX card CH5 D/D information: Wave length
1.3.6.1.4.1.4756.20.700.20.1.172Columnf10GMUXCH5DDWaveLen2Localread-onlycurrentLocal FRM220-TM-10GMUX card CH5 D/D information: Wave length 2
1.3.6.1.4.1.4756.20.700.20.1.173Columnf10GMUXCH5DDLinkLenLocalread-onlycurrentLocal FRM220-TM-10GMUX card CH5 D/D information: Link length
1.3.6.1.4.1.4756.20.700.20.1.174Columnf10GMUXCH5DDLenUnitLocalread-onlycurrentLocal FRM220-10GMUX card CH5 D/D information: Length Unit
1.3.6.1.4.1.4756.20.700.20.1.175Columnf10GMUXCH5DDRxSensLocalread-onlycurrentLocal FRM220-TM-10GMUX card CH5 D/D information: Rx Sensitivity
1.3.6.1.4.1.4756.20.700.20.1.176Columnf10GMUXCH5DDTxPWRLocalread-onlycurrentLocal FRM220-TM-10GMUX card CH5 D/D information: Tx power
1.3.6.1.4.1.4756.20.700.20.1.177Columnf10GMUXCH5DDRxPWRLocalread-onlycurrentLocal FRM220-TM-10GMUX card CH5 D/D information: Rx power
1.3.6.1.4.1.4756.20.700.20.1.178Columnf10GMUXCH5DDTempLocalread-onlycurrentLocal FRM220-TM-10GMUX card CH5 D/D information: Temperature in degree C
1.3.6.1.4.1.4756.20.700.20.1.179Columnf10GMUXCH5SupplyVolLocalread-onlycurrentLocal FRM220-TM-10GMUX card CH5 D/D information: SupplyVol
1.3.6.1.4.1.4756.20.700.20.1.180Columnf10GMUXCH5TxLaserBiasLocalread-onlycurrentLocal FRM220-TM-10GMUX card CH5 D/D information: Tx LaserBias
1.3.6.1.4.1.4756.20.700.20.1.181Columnf10GMUXCH6DDVendorLocalread-onlycurrentLocal FRM220-TM-10GMUX card CH6 D/D information: Vendor name
1.3.6.1.4.1.4756.20.700.20.1.182Columnf10GMUXCH6DDPartNoLocalread-onlycurrentLocal FRM220-TM-10GMUX card CH6 D/D information: Vendor part number
1.3.6.1.4.1.4756.20.700.20.1.183Columnf10GMUXCH6DDVendorSNLocalread-onlycurrentLocal FRM220-TM-10GMUX card CH6 D/D information: Vendor SN
1.3.6.1.4.1.4756.20.700.20.1.184Columnf10GMUXCH6DDFiberTypeLocalread-onlycurrentLocal FRM220-TM-10GMUX card CH6 D/D information: Fiber Type
1.3.6.1.4.1.4756.20.700.20.1.185Columnf10GMUXCH6DDWaveLenLocalread-onlycurrentLocal FRM220-TM-10GMUX card CH6 D/D information: Wave length
1.3.6.1.4.1.4756.20.700.20.1.186Columnf10GMUXCH6DDWaveLen2Localread-onlycurrentLocal FRM220-TM-10GMUX card CH6 D/D information: Wave length 2
1.3.6.1.4.1.4756.20.700.20.1.187Columnf10GMUXCH6DDLinkLenLocalread-onlycurrentLocal FRM220-TM-10GMUX card CH6 D/D information: Link length
1.3.6.1.4.1.4756.20.700.20.1.188Columnf10GMUXCH6DDLenUnitLocalread-onlycurrentLocal FRM220-10GMUX card CH6 D/D information: Length Unit
1.3.6.1.4.1.4756.20.700.20.1.189Columnf10GMUXCH6DDRxSensLocalread-onlycurrentLocal FRM220-TM-10GMUX card CH6 D/D information: Rx Sensitivity
1.3.6.1.4.1.4756.20.700.20.1.190Columnf10GMUXCH6DDTxPWRLocalread-onlycurrentLocal FRM220-TM-10GMUX card CH6 D/D information: Tx power
1.3.6.1.4.1.4756.20.700.20.1.191Columnf10GMUXCH6DDRxPWRLocalread-onlycurrentLocal FRM220-TM-10GMUX card CH6 D/D information: Rx power
1.3.6.1.4.1.4756.20.700.20.1.192Columnf10GMUXCH6DDTempLocalread-onlycurrentLocal FRM220-TM-10GMUX card CH6 D/D information: Temperature in degree C
1.3.6.1.4.1.4756.20.700.20.1.193Columnf10GMUXCH6SupplyVolLocalread-onlycurrentLocal FRM220-TM-10GMUX card CH6 D/D information: SupplyVol
1.3.6.1.4.1.4756.20.700.20.1.194Columnf10GMUXCH6TxLaserBiasLocalread-onlycurrentLocal FRM220-TM-10GMUX card CH6 D/D information: Tx LaserBias
1.3.6.1.4.1.4756.20.700.20.1.195Columnf10GMUXCH7DDVendorLocalread-onlycurrentLocal FRM220-TM-10GMUX card CH7 D/D information: Vendor name
1.3.6.1.4.1.4756.20.700.20.1.196Columnf10GMUXCH7DDPartNoLocalread-onlycurrentLocal FRM220-TM-10GMUX card CH7 D/D information: Vendor part number
1.3.6.1.4.1.4756.20.700.20.1.197Columnf10GMUXCH7DDVendorSNLocalread-onlycurrentLocal FRM220-TM-10GMUX card CH7 D/D information: Vendor SN
1.3.6.1.4.1.4756.20.700.20.1.198Columnf10GMUXCH7DDFiberTypeLocalread-onlycurrentLocal FRM220-TM-10GMUX card CH7 D/D information: Fiber Type
1.3.6.1.4.1.4756.20.700.20.1.199Columnf10GMUXCH7DDWaveLenLocalread-onlycurrentLocal FRM220-TM-10GMUX card CH7 D/D information: Wave length
1.3.6.1.4.1.4756.20.700.20.1.200Columnf10GMUXCH7DDWaveLen2Localread-onlycurrentLocal FRM220-TM-10GMUX card CH7 D/D information: Wave length 2
1.3.6.1.4.1.4756.20.700.20.1.201Columnf10GMUXCH7DDLinkLenLocalread-onlycurrentLocal FRM220-TM-10GMUX card CH7 D/D information: Link length
1.3.6.1.4.1.4756.20.700.20.1.202Columnf10GMUXCH7DDLenUnitLocalread-onlycurrentLocal FRM220-10GMUX card CH7 D/D information: Length Unit
1.3.6.1.4.1.4756.20.700.20.1.203Columnf10GMUXCH7DDRxSensLocalread-onlycurrentLocal FRM220-TM-10GMUX card CH7 D/D information: Rx Sensitivity
1.3.6.1.4.1.4756.20.700.20.1.204Columnf10GMUXCH7DDTxPWRLocalread-onlycurrentLocal FRM220-TM-10GMUX card CH7 D/D information: Tx power
1.3.6.1.4.1.4756.20.700.20.1.205Columnf10GMUXCH7DDRxPWRLocalread-onlycurrentLocal FRM220-TM-10GMUX card CH7 D/D information: Rx power
1.3.6.1.4.1.4756.20.700.20.1.206Columnf10GMUXCH7DDTempLocalread-onlycurrentLocal FRM220-TM-10GMUX card CH7 D/D information: Temperature in degree C
1.3.6.1.4.1.4756.20.700.20.1.207Columnf10GMUXCH7SupplyVolLocalread-onlycurrentLocal FRM220-TM-10GMUX card CH7 D/D information: SupplyVol
1.3.6.1.4.1.4756.20.700.20.1.208Columnf10GMUXCH7TxLaserBiasLocalread-onlycurrentLocal FRM220-TM-10GMUX card CH7 D/D information: Tx LaserBias
1.3.6.1.4.1.4756.20.700.20.1.209Columnf10GMUXDeviceActiveLocalread-writecurrentLocal FRM220-TM-10GMUX card active: 0:Inactive 1:Active
1.3.6.1.4.1.4756.20.700.20.1.210Columnf10GMUXClrCVCntsLocalread-writecurrentClear local device card CV IN/OUT counters: 0:No action 1:Action
1.3.6.1.4.1.4756.20.700.20.1.211Columnf10GMUXTunableLinechORfreqLocalread-writecurrentLocal FRM220-TM-10GMUX card Tunable Line chORfreq Mode. 0: Channel 1: Frequency
1.3.6.1.4.1.4756.20.700.20.1.212Columnf10GMUXTunableLineChannelLocalread-writecurrentLocal FRM220-TM-10GMUX card Tunable Line Channel setting.
1.3.6.1.4.1.4756.20.700.20.1.213Columnf10GMUXTunableLineFrequencyLocalread-writecurrentLocal FRM220-TM-10GMUX card Tunable Line Frequency setting.
1.3.6.1.4.1.4756.20.700.20.1.214Columnf10GMUXPowerLedLocalread-onlycurrentLocal FRM220-TM-10GMUX card Powe Led. 0:ON (Power ON) 1:Flash (Standby; 1s ON/1s OFF)
1.3.6.1.4.1.4756.20.700.20.1.215Columnf10GMUXSystemLedLocalread-onlycurrentLocal FRM220-TM-10GMUX card Syetem Led. 0:OFF 1:Link up 2:ON
1.3.6.1.4.1.4756.20.700.20.1.216Columnf10GMUXAlarmLedLocalread-onlycurrentLocal FRM220-TM-10GMUX card Alarm Led. 0:OFF 1:ON
1.3.6.1.4.1.4756.20.700.20.1.217Columnf10GMUXLFPTLedLocalread-onlycurrentLocal FRM220-TM-10GMUX card LFPT Led. 0:OFF 1:ON
1.3.6.1.4.1.4756.20.700.20.1.218Columnf10GMUXLineLedLocalread-onlycurrentLocal FRM220-TM-10GMUX card Line Led. 0:OFF(Link Down) 1:link up (On: 0.5s, Off: 0.5s) 2:LB (On: 1s, Off: 1s) 3:ON (0.5s ON/0.5s OFF)
1.3.6.1.4.1.4756.20.700.20.1.219Columnf10GMUXCH1LedLocalread-onlycurrentLocal FRM220-TM-10GMUX card CH1 Led. 0:OFF(Link Down) 1:link up (On: 0.5s, Off: 0.5s) 2:LB (On: 1s, Off: 1s) 3:ON (0.5s ON/0.5s OFF)
1.3.6.1.4.1.4756.20.700.20.1.220Columnf10GMUXCH2LedLocalread-onlycurrentLocal FRM220-TM-10GMUX card CH2 Led. 0:OFF(Link Down) 1:link up (On: 0.5s, Off: 0.5s) 2:LB (On: 1s, Off: 1s) 3:ON (0.5s ON/0.5s OFF)
1.3.6.1.4.1.4756.20.700.20.1.221Columnf10GMUXCH3LedLocalread-onlycurrentLocal FRM220-TM-10GMUX card CH3 Led. 0:OFF(Link Down) 1:link up (On: 0.5s, Off: 0.5s) 2:LB (On: 1s, Off: 1s) 3:ON (0.5s ON/0.5s OFF)
1.3.6.1.4.1.4756.20.700.20.1.222Columnf10GMUXCH4LedLocalread-onlycurrentLocal FRM220-TM-10GMUX card CH4 Led. 0:OFF(Link Down) 1:link up (On: 0.5s, Off: 0.5s) 2:LB (On: 1s, Off: 1s) 3:ON (0.5s ON/0.5s OFF)
1.3.6.1.4.1.4756.20.700.20.1.223Columnf10GMUXCH5LedLocalread-onlycurrentLocal FRM220-TM-10GMUX card CH5 Led. 0:OFF(Link Down) 1:link up (On: 0.5s, Off: 0.5s) 2:LB (On: 1s, Off: 1s) 3:ON (0.5s ON/0.5s OFF)
1.3.6.1.4.1.4756.20.700.20.1.224Columnf10GMUXCH6LedLocalread-onlycurrentLocal FRM220-TM-10GMUX card CH6 Led. 0:OFF(Link Down) 1:link up (On: 0.5s, Off: 0.5s) 2:LB (On: 1s, Off: 1s) 3:ON (0.5s ON/0.5s OFF)
1.3.6.1.4.1.4756.20.700.20.1.225Columnf10GMUXCH7LedLocalread-onlycurrentLocal FRM220-TM-10GMUX card CH7 Led. 0:OFF(Link Down) 1:link up (On: 0.5s, Off: 0.5s) 2:LB (On: 1s, Off: 1s) 3:ON (0.5s ON/0.5s OFF)
1.3.6.1.4.1.4756.20.701Nodef10GMUXRemoteCards
1.3.6.1.4.1.4756.20.701.20Tablef10GMUXRemoteTablenot-accessiblecurrentA list of local FRM220-TM-10GMUX Line Card entries. The number of entries is f10GMUX-No-L.
1.3.6.1.4.1.4756.20.701.20.1Rowf10GMUXRemoteEntrynot-accessiblecurrentAn entry containing management information applicable to a particular local FRM220-TM-10GMUX Line Card.
1.3.6.1.4.1.4756.20.701.20.1.1Columnf10GMUXChassisIndexRemoteread-onlycurrentA unique value for each local card. It is the chassis location number.
1.3.6.1.4.1.4756.20.701.20.1.2Columnf10GMUXSlotIndexRemoteread-onlycurrentA unique value for each local card. It is the slot location number.
1.3.6.1.4.1.4756.20.701.20.1.3Columnf10GMUXCardHWVerRemoteread-onlycurrentLocal FRM220-TM-10GMUX Line Card hardware version x.xxx
1.3.6.1.4.1.4756.20.701.20.1.4Columnf10GMUXCardFWVerRemoteread-onlycurrentLocal FRM220-TM-10GMUX Line Card firmware version x.xxx
1.3.6.1.4.1.4756.20.701.20.1.5Columnf10GMUXCardCPLDVerRemoteread-onlycurrentLocal FRM220-TM-10GMUX Line Card CPLD version x.xxx
1.3.6.1.4.1.4756.20.701.20.1.6Columnf10GMUXCardFPGAVerRemoteread-onlycurrentLocal FRM220-TM-10GMUX Line Card FPGA version x.xxx
1.3.6.1.4.1.4756.20.701.20.1.7Columnf10GMUXPortResetRemoteread-writecurrentLocal FRM220-TM-10GMUX card to reset mode: 0:Off 1:Action
1.3.6.1.4.1.4756.20.701.20.1.8Columnf10GMUXSetToDefaultRemoteread-writecurrentLocal FRM220-TM-10GMUX card set to default : 0:Off 1:Action
1.3.6.1.4.1.4756.20.701.20.1.9Columnf10GMUXLineExistRemoteread-onlycurrentLocal FRM220-TM-10GMUX card Line Exist status: 0:Empty 1:Exist
1.3.6.1.4.1.4756.20.701.20.1.10Columnf10GMUXCH1ExistRemoteread-onlycurrentLocal FRM220-TM-10GMUX card CH1 Exist status: 0:Empty 1:Exist
1.3.6.1.4.1.4756.20.701.20.1.11Columnf10GMUXCH2ExistRemoteread-onlycurrentLocal FRM220-TM-10GMUX card CH2 Exist status: 0:Empty 1:Exist
1.3.6.1.4.1.4756.20.701.20.1.12Columnf10GMUXCH3ExistRemoteread-onlycurrentLocal FRM220-TM-10GMUX card CH3 Exist status: 0:Empty 1:Exist
1.3.6.1.4.1.4756.20.701.20.1.13Columnf10GMUXCH4ExistRemoteread-onlycurrentLocal FRM220-TM-10GMUX card CH4 Exist status: 0:Empty 1:Exist
1.3.6.1.4.1.4756.20.701.20.1.14Columnf10GMUXCH5ExistRemoteread-onlycurrentLocal FRM220-TM-10GMUX card CH5 Exist status: 0:Empty 1:Exist
1.3.6.1.4.1.4756.20.701.20.1.15Columnf10GMUXCH6ExistRemoteread-onlycurrentLocal FRM220-TM-10GMUX card CH6 Exist status: 0:Empty 1:Exist
1.3.6.1.4.1.4756.20.701.20.1.16Columnf10GMUXCH7ExistRemoteread-onlycurrentLocal FRM220-TM-10GMUX card CH7 Exist status: 0:Empty 1:Exist
1.3.6.1.4.1.4756.20.701.20.1.17Columnf10GMUXLineLinkRemoteread-onlycurrentLocal FRM220-TM-10GMUX card Line Link status: 0:Down 1:up
1.3.6.1.4.1.4756.20.701.20.1.18Columnf10GMUXCH1LinkRemoteread-onlycurrentLocal FRM220-TM-10GMUX card CH1 Link status: 0:Down 1:up
1.3.6.1.4.1.4756.20.701.20.1.19Columnf10GMUXCH2LinkRemoteread-onlycurrentLocal FRM220-TM-10GMUX card CH2 Link status: 0:Down 1:up
1.3.6.1.4.1.4756.20.701.20.1.20Columnf10GMUXCH3LinkRemoteread-onlycurrentLocal FRM220-TM-10GMUX card CH3 Link status: 0:Down 1:up
1.3.6.1.4.1.4756.20.701.20.1.21Columnf10GMUXCH4LinkRemoteread-onlycurrentLocal FRM220-TM-10GMUX card CH4 Link status: 0:Down 1:up
1.3.6.1.4.1.4756.20.701.20.1.22Columnf10GMUXCH5LinkRemoteread-onlycurrentLocal FRM220-TM-10GMUX card CH5 Link status: 0:Down 1:up
1.3.6.1.4.1.4756.20.701.20.1.23Columnf10GMUXCH6LinkRemoteread-onlycurrentLocal FRM220-TM-10GMUX card CH6 Link status: 0:Down 1:up
1.3.6.1.4.1.4756.20.701.20.1.24Columnf10GMUXCH7LinkRemoteread-onlycurrentLocal FRM220-TM-10GMUX card CH7 Link status: 0:Down 1:up
1.3.6.1.4.1.4756.20.701.20.1.25Columnf10GMUXLineSyncRemoteread-onlycurrentLocal FRM220-TM-10GMUX card Line Sync status: 0:No 1:Yes
1.3.6.1.4.1.4756.20.701.20.1.26Columnf10GMUXCH1SyncRemoteread-onlycurrentLocal FRM220-TM-10GMUX card CH1 Sync status: 0:No 1:Yes
1.3.6.1.4.1.4756.20.701.20.1.27Columnf10GMUXCH2SyncRemoteread-onlycurrentLocal FRM220-TM-10GMUX card CH2 Sync status: 0:No 1:Yes
1.3.6.1.4.1.4756.20.701.20.1.28Columnf10GMUXCH3SyncRemoteread-onlycurrentLocal FRM220-TM-10GMUX card CH3 Sync status: 0:No 1:Yes
1.3.6.1.4.1.4756.20.701.20.1.29Columnf10GMUXCH4SyncRemoteread-onlycurrentLocal FRM220-TM-10GMUX card CH4 Sync status: 0:Not Locked 1:Yes
1.3.6.1.4.1.4756.20.701.20.1.30Columnf10GMUXCH5SyncRemoteread-onlycurrentLocal FRM220-TM-10GMUX card CH5 Sync status: 0:No 1:Yes
1.3.6.1.4.1.4756.20.701.20.1.31Columnf10GMUXCH6SyncRemoteread-onlycurrentLocal FRM220-TM-10GMUX card CH6 Sync status: 0:No 1:Yes
1.3.6.1.4.1.4756.20.701.20.1.32Columnf10GMUXCH7SyncRemoteread-onlycurrentLocal FRM220-TM-10GMUX card CH7 Sync status: 0:no 1:yes
1.3.6.1.4.1.4756.20.701.20.1.33Columnf10GMUXLineTxFaultRemoteread-onlycurrentLocal FRM220-TM-10GMUX card Line Tx Fault status: 0:Normal 1:Failure
1.3.6.1.4.1.4756.20.701.20.1.34Columnf10GMUXCH1TxFaultRemoteread-onlycurrentLocal FRM220-TM-10GMUX card CH1 Tx Fault status: 0:Normal 1:Failure
1.3.6.1.4.1.4756.20.701.20.1.35Columnf10GMUXCH2TxFaultRemoteread-onlycurrentLocal FRM220-TM-10GMUX card CH2 Tx Fault status: 0:Normal 1:Failure
1.3.6.1.4.1.4756.20.701.20.1.36Columnf10GMUXCH3TxFaultRemoteread-onlycurrentLocal FRM220-TM-10GMUX card CH3 Tx Fault status: 0:Normal 1:Failure
1.3.6.1.4.1.4756.20.701.20.1.37Columnf10GMUXCH4TxFaultRemoteread-onlycurrentLocal FRM220-TM-10GMUX card CH4 Tx Fault status: 0:Normal 1:Failure
1.3.6.1.4.1.4756.20.701.20.1.38Columnf10GMUXCH5TxFaultRemoteread-onlycurrentLocal FRM220-TM-10GMUX card CH5 Tx Fault status: 0:Normal 1:Failure
1.3.6.1.4.1.4756.20.701.20.1.39Columnf10GMUXCH6TxFaultRemoteread-onlycurrentLocal FRM220-TM-10GMUX card CH6 Tx Fault status: 0:Normal 1:Failure
1.3.6.1.4.1.4756.20.701.20.1.40Columnf10GMUXCH7TxFaultRemoteread-onlycurrentLocal FRM220-TM-10GMUX card CH7 Tx Fault status: 0:Normal 1:Failure
1.3.6.1.4.1.4756.20.701.20.1.41Columnf10GMUXLineDDRemoteread-onlycurrentLocal FRM220-TM-10GMUX card Line DD status: 0:no 1:yes
1.3.6.1.4.1.4756.20.701.20.1.42Columnf10GMUXCH1DDRemoteread-onlycurrentLocal FRM220-TM-10GMUX card CH1 DD status: 0:no 1:yes
1.3.6.1.4.1.4756.20.701.20.1.43Columnf10GMUXCH2DDRemoteread-onlycurrentLocal FRM220-TM-10GMUX card CH2 DD status: 0:no 1:yes
1.3.6.1.4.1.4756.20.701.20.1.44Columnf10GMUXCH3DDRemoteread-onlycurrentLocal FRM220-TM-10GMUX card CH3 DD status: 0:no 1:yes
1.3.6.1.4.1.4756.20.701.20.1.45Columnf10GMUXCH4DDRemoteread-onlycurrentLocal FRM220-TM-10GMUX card CH4 DD status: 0:no 1:yes
1.3.6.1.4.1.4756.20.701.20.1.46Columnf10GMUXCH5DDRemoteread-onlycurrentLocal FRM220-TM-10GMUX card CH5 DD status: 0:no 1:yes
1.3.6.1.4.1.4756.20.701.20.1.47Columnf10GMUXCH6DDRemoteread-onlycurrentLocal FRM220-TM-10GMUX card CH6 DD status: 0:no 1:yes
1.3.6.1.4.1.4756.20.701.20.1.48Columnf10GMUXCH7DDRemoteread-onlycurrentLocal FRM220-TM-10GMUX card CH7 DD status: 0:no 1:yes
1.3.6.1.4.1.4756.20.701.20.1.49Columnf10GMUXLineCounterRemoteread-onlycurrentFRM220-10GMUX cards Line Counter.
1.3.6.1.4.1.4756.20.701.20.1.50Columnf10GMUXCH1CounterRemoteread-onlycurrentFRM220-10GMUX cards CH1 Counter.
1.3.6.1.4.1.4756.20.701.20.1.51Columnf10GMUXCH2CounterRemoteread-onlycurrentFRM220-10GMUX cards CH2 Counter.
1.3.6.1.4.1.4756.20.701.20.1.52Columnf10GMUXCH3CounterRemoteread-onlycurrentFRM220-10GMUX cards CH3 Counter.
1.3.6.1.4.1.4756.20.701.20.1.53Columnf10GMUXCH4CounterRemoteread-onlycurrentFRM220-10GMUX cards CH4 Counter.
1.3.6.1.4.1.4756.20.701.20.1.54Columnf10GMUXCH5CounterRemoteread-onlycurrentFRM220-10GMUX cards CH5 Counter.
1.3.6.1.4.1.4756.20.701.20.1.55Columnf10GMUXCH6CounterRemoteread-onlycurrentFRM220-10GMUX cards CH6 Counter.
1.3.6.1.4.1.4756.20.701.20.1.56Columnf10GMUXCH7CounterRemoteread-onlycurrentFRM220-10GMUX cards CH7 Counter.
1.3.6.1.4.1.4756.20.701.20.1.57Columnf10GMUXLinePortActiveRemoteread-onlycurrentFRM220-10GMUX cards Line Port Active: 0:disable 1:enable
1.3.6.1.4.1.4756.20.701.20.1.58Columnf10GMUXCH1PortActiveRemoteread-writecurrentFRM220-10GMUX cards CH1 Port Active: 0:disable 1:enable
1.3.6.1.4.1.4756.20.701.20.1.59Columnf10GMUXCH2PortActiveRemoteread-writecurrentFRM220-10GMUX cards CH2 Port Active: 0:disable 1:enable
1.3.6.1.4.1.4756.20.701.20.1.60Columnf10GMUXCH3PortActiveRemoteread-writecurrentFRM220-10GMUX cards CH3 Port Active: 0:disable 1:enable
1.3.6.1.4.1.4756.20.701.20.1.61Columnf10GMUXCH4PortActiveRemoteread-writecurrentFRM220-10GMUX cards CH4 Port Active: 0:disable 1:enable
1.3.6.1.4.1.4756.20.701.20.1.62Columnf10GMUXCH5PortActiveRemoteread-writecurrentFRM220-10GMUX cards CH5 Port Active: 0:disable 1:enable
1.3.6.1.4.1.4756.20.701.20.1.63Columnf10GMUXCH6PortActiveRemoteread-writecurrentFRM220-10GMUX cards CH6 Port Active: 0:disable 1:enable
1.3.6.1.4.1.4756.20.701.20.1.64Columnf10GMUXCH7PortActiveRemoteread-writecurrentFRM220-10GMUX cards CH7 Port Active: 0:disable 1:enable
1.3.6.1.4.1.4756.20.701.20.1.65Columnf10GMUXLineLFPRemoteread-writecurrentLocal FRM220-TM-10GMUX card Line Link Fault Pass Through: 0:Disable 1:Enable
1.3.6.1.4.1.4756.20.701.20.1.66Columnf10GMUXCH1LFPRemoteread-writecurrentLocal FRM220-TM-10GMUX card CH1 Link Fault Pass Through: 0:Disable 1:Enable
1.3.6.1.4.1.4756.20.701.20.1.67Columnf10GMUXCH2LFPRemoteread-writecurrentLocal FRM220-TM-10GMUX card CH2 Link Fault Pass Through: 0:Disable 1:Enable
1.3.6.1.4.1.4756.20.701.20.1.68Columnf10GMUXCH3LFPRemoteread-writecurrentLocal FRM220-TM-10GMUX card CH3 Link Fault Pass Through: 0:Disable 1:Enable
1.3.6.1.4.1.4756.20.701.20.1.69Columnf10GMUXCH4LFPRemoteread-writecurrentLocal FRM220-TM-10GMUX card CH4 Link Fault Pass Through: 0:Disable 1:Enable
1.3.6.1.4.1.4756.20.701.20.1.70Columnf10GMUXCH5LFPRemoteread-writecurrentLocal FRM220-TM-10GMUX card CH5 Link Fault Pass Through: 0:Disable 1:Enable
1.3.6.1.4.1.4756.20.701.20.1.71Columnf10GMUXCH6LFPRemoteread-writecurrentLocal FRM220-TM-10GMUX card CH6 Link Fault Pass Through: 0:Disable 1:Enable
1.3.6.1.4.1.4756.20.701.20.1.72Columnf10GMUXCH7LFPRemoteread-writecurrentLocal FRM220-TM-10GMUX card CH7 Link Fault Pass Through: 0:Disable 1:Enable
1.3.6.1.4.1.4756.20.701.20.1.73Columnf10GMUXLineALSRemoteread-writecurrentLocal FRM220-TM-10GMUX card Line Auto Laser Showdown: 0:Disable 1:Enable
1.3.6.1.4.1.4756.20.701.20.1.74Columnf10GMUXCH1ALSRemoteread-writecurrentLocal FRM220-TM-10GMUX card CH1 Auto Laser Showdown: 0:Disable 1:Enable
1.3.6.1.4.1.4756.20.701.20.1.75Columnf10GMUXCH2ALSRemoteread-writecurrentLocal FRM220-TM-10GMUX card CH2 Auto Laser Showdown: 0:Disable 1:Enable
1.3.6.1.4.1.4756.20.701.20.1.76Columnf10GMUXCH3ALSRemoteread-writecurrentLocal FRM220-TM-10GMUX card CH3 Auto Laser Showdown: 0:Disable 1:Enable
1.3.6.1.4.1.4756.20.701.20.1.77Columnf10GMUXCH4ALSRemoteread-writecurrentLocal FRM220-TM-10GMUX card CH4 Auto Laser Showdown: 0:Disable 1:Enable
1.3.6.1.4.1.4756.20.701.20.1.78Columnf10GMUXCH5ALSRemoteread-writecurrentLocal FRM220-TM-10GMUX card CH5 Auto Laser Showdown: 0:Disable 1:Enable
1.3.6.1.4.1.4756.20.701.20.1.79Columnf10GMUXCH6ALSRemoteread-writecurrentLocal FRM220-TM-10GMUX card CH6 Auto Laser Showdown: 0:Disable 1:Enable
1.3.6.1.4.1.4756.20.701.20.1.80Columnf10GMUXCH7ALSRemoteread-writecurrentLocal FRM220-TM-10GMUX card CH7 Auto Laser Showdown: 0:Disable 1:Enable
1.3.6.1.4.1.4756.20.701.20.1.81Columnf10GMUXCH1LoopbackRemoteread-writecurrentLocal FRM220-TM-10GMUX card CH1 Loopback: 0:Disable 1:Enable
1.3.6.1.4.1.4756.20.701.20.1.82Columnf10GMUXCH2LoopbackRemoteread-writecurrentLocal FRM220-TM-10GMUX card CH2 Loopback: 0:Disable 1:Enable
1.3.6.1.4.1.4756.20.701.20.1.83Columnf10GMUXCH3LoopbackRemoteread-writecurrentLocal FRM220-TM-10GMUX card CH3 Loopback: 0:Disable 1:Enable
1.3.6.1.4.1.4756.20.701.20.1.84Columnf10GMUXCH4LoopbackRemoteread-writecurrentLocal FRM220-TM-10GMUX card CH4 Loopback: 0:Disable 1:Enable
1.3.6.1.4.1.4756.20.701.20.1.85Columnf10GMUXCH5LoopbackRemoteread-writecurrentLocal FRM220-TM-10GMUX card CH5 Loopback: 0:Disable 1:Enable
1.3.6.1.4.1.4756.20.701.20.1.86Columnf10GMUXCH6LoopbackRemoteread-writecurrentLocal FRM220-TM-10GMUX card CH6 Loopback: 0:Disable 1:Enable
1.3.6.1.4.1.4756.20.701.20.1.87Columnf10GMUXCH7LoopbackRemoteread-writecurrentLocal FRM220-TM-10GMUX card CH7 Loopback: 0:Disable 1:Enable
1.3.6.1.4.1.4756.20.701.20.1.88Columnf10GMUXAlarmStatusRemoteread-onlycurrentLocal FRM220-TM-10GMUX card Alarm status: 0:Normal 1:Abmormal
1.3.6.1.4.1.4756.20.701.20.1.89Columnf10GMUXLineTriggerRemoteread-writecurrentFRM220-10GMUX cards Line Trigger: 0:disable 1:enable
1.3.6.1.4.1.4756.20.701.20.1.90Columnf10GMUXCH1TriggerRemoteread-writecurrentFRM220-10GMUX cards CH1 Trigger: 0:disable 1:enable
1.3.6.1.4.1.4756.20.701.20.1.91Columnf10GMUXCH2TriggerRemoteread-writecurrentFRM220-10GMUX cards CH2 Trigger: 0:disable 1:enable
1.3.6.1.4.1.4756.20.701.20.1.92Columnf10GMUXCH3TriggerRemoteread-writecurrentFRM220-10GMUX cards CH3 Trigger: 0:disable 1:enable
1.3.6.1.4.1.4756.20.701.20.1.93Columnf10GMUXCH4TriggerRemoteread-writecurrentFRM220-10GMUX cards CH4 Trigger: 0:disable 1:enable
1.3.6.1.4.1.4756.20.701.20.1.94Columnf10GMUXCH5TriggerRemoteread-writecurrentFRM220-10GMUX cards CH5 Trigger: 0:disable 1:enable
1.3.6.1.4.1.4756.20.701.20.1.95Columnf10GMUXCH6TriggerRemoteread-writecurrentFRM220-10GMUX cards CH6 Trigger: 0:disable 1:enable
1.3.6.1.4.1.4756.20.701.20.1.96Columnf10GMUXCH7TriggerRemoteread-writecurrentFRM220-10GMUX cards CH7 Trigger: 0:disable 1:enable
1.3.6.1.4.1.4756.20.701.20.1.97Columnf10GMUXLineDDVendorRemoteread-onlycurrentLocal FRM220-TM-10GMUX card Line D/D information: Vendor name
1.3.6.1.4.1.4756.20.701.20.1.98Columnf10GMUXLineDDPartNoRemoteread-onlycurrentLocal FRM220-TM-10GMUX card Line D/D information: Vendor part number
1.3.6.1.4.1.4756.20.701.20.1.99Columnf10GMUXLineDDVendorSNRemoteread-onlycurrentLocal FRM220-TM-10GMUX card Line D/D information: Vendor SN
1.3.6.1.4.1.4756.20.701.20.1.100Columnf10GMUXLineDDFiberTypeRemoteread-onlycurrentLocal FRM220-TM-10GMUX card Line D/D information: Fiber Type
1.3.6.1.4.1.4756.20.701.20.1.101Columnf10GMUXLineDDWaveLenRemoteread-onlycurrentLocal FRM220-TM-10GMUX card Line D/D information: Wave length
1.3.6.1.4.1.4756.20.701.20.1.102Columnf10GMUXLineDDWaveLen2Remoteread-onlycurrentLocal FRM220-TM-10GMUX card Line D/D information: Wave length 2
1.3.6.1.4.1.4756.20.701.20.1.103Columnf10GMUXLineDDLinkLenRemoteread-onlycurrentLocal FRM220-TM-10GMUX card Line D/D information: Link length
1.3.6.1.4.1.4756.20.701.20.1.104Columnf10GMUXLineDDLenUnitRemoteread-onlycurrentRemote FRM220-10GMUX card Line D/D information: Length Unit
1.3.6.1.4.1.4756.20.701.20.1.105Columnf10GMUXLineDDRxSensRemoteread-onlycurrentLocal FRM220-TM-10GMUX card Line D/D information: Rx Sensitivity
1.3.6.1.4.1.4756.20.701.20.1.106Columnf10GMUXLineDDTxPWRRemoteread-onlycurrentLocal FRM220-TM-10GMUX card Line D/D information: Tx power
1.3.6.1.4.1.4756.20.701.20.1.107Columnf10GMUXLineDDRxPWRRemoteread-onlycurrentLocal FRM220-TM-10GMUX card Line D/D information: Rx power
1.3.6.1.4.1.4756.20.701.20.1.108Columnf10GMUXLineDDTempRemoteread-onlycurrentLocal FRM220-TM-10GMUX card Line D/D information: Temperature in degree C
1.3.6.1.4.1.4756.20.701.20.1.109Columnf10GMUXLineSupplyVolRemoteread-onlycurrentLocal FRM220-TM-10GMUX card Line D/D information: SupplyVol
1.3.6.1.4.1.4756.20.701.20.1.110Columnf10GMUXLineTxLaserBiasRemoteread-onlycurrentLocal FRM220-TM-10GMUX card Line D/D information: Tx LaserBias
1.3.6.1.4.1.4756.20.701.20.1.111Columnf10GMUXCH1DDVendorRemoteread-onlycurrentLocal FRM220-TM-10GMUX card CH1 D/D information: Vendor name
1.3.6.1.4.1.4756.20.701.20.1.112Columnf10GMUXCH1DDPartNoRemoteread-onlycurrentLocal FRM220-TM-10GMUX card CH1 D/D information: Vendor part number
1.3.6.1.4.1.4756.20.701.20.1.113Columnf10GMUXCH1DDVendorSNRemoteread-onlycurrentLocal FRM220-TM-10GMUX card CH1 D/D information: Vendor SN
1.3.6.1.4.1.4756.20.701.20.1.114Columnf10GMUXCH1DDFiberTypeRemoteread-onlycurrentLocal FRM220-TM-10GMUX card CH1 D/D information: Fiber Type
1.3.6.1.4.1.4756.20.701.20.1.115Columnf10GMUXCH1DDWaveLenRemoteread-onlycurrentLocal FRM220-TM-10GMUX card CH1 D/D information: Wave length
1.3.6.1.4.1.4756.20.701.20.1.116Columnf10GMUXCH1DDWaveLen2Remoteread-onlycurrentLocal FRM220-TM-10GMUX card CH1 D/D information: Wave length 2
1.3.6.1.4.1.4756.20.701.20.1.117Columnf10GMUXCH1DDLinkLenRemoteread-onlycurrentLocal FRM220-TM-10GMUX card CH1 D/D information: Link length
1.3.6.1.4.1.4756.20.701.20.1.118Columnf10GMUXCH1DDLenUnitRemoteread-onlycurrentRemote FRM220-10GMUX card CH1 D/D information: Length Unit
1.3.6.1.4.1.4756.20.701.20.1.119Columnf10GMUXCH1DDRxSensRemoteread-onlycurrentLocal FRM220-TM-10GMUX card CH1 D/D information: Rx Sensitivity
1.3.6.1.4.1.4756.20.701.20.1.120Columnf10GMUXCH1DDTxPWRRemoteread-onlycurrentLocal FRM220-TM-10GMUX card CH1 D/D information: Tx power
1.3.6.1.4.1.4756.20.701.20.1.121Columnf10GMUXCH1DDRxPWRRemoteread-onlycurrentLocal FRM220-TM-10GMUX card CH1 D/D information: Rx power
1.3.6.1.4.1.4756.20.701.20.1.122Columnf10GMUXCH1DDTempRemoteread-onlycurrentLocal FRM220-TM-10GMUX card CH1 D/D information: Temperature in degree C
1.3.6.1.4.1.4756.20.701.20.1.123Columnf10GMUXCH1SupplyVolRemoteread-onlycurrentLocal FRM220-TM-10GMUX card CH1 D/D information: SupplyVol
1.3.6.1.4.1.4756.20.701.20.1.124Columnf10GMUXCH1TxLaserBiasRemoteread-onlycurrentLocal FRM220-TM-10GMUX card CH1 D/D information: Tx LaserBias
1.3.6.1.4.1.4756.20.701.20.1.125Columnf10GMUXCH2DDVendorRemoteread-onlycurrentLocal FRM220-TM-10GMUX card CH2 D/D information: Vendor name
1.3.6.1.4.1.4756.20.701.20.1.126Columnf10GMUXCH2DDPartNoRemoteread-onlycurrentLocal FRM220-TM-10GMUX card CH2 D/D information: Vendor part number
1.3.6.1.4.1.4756.20.701.20.1.127Columnf10GMUXCH2DDVendorSNRemoteread-onlycurrentLocal FRM220-TM-10GMUX card CH2 D/D information: Vendor SN
1.3.6.1.4.1.4756.20.701.20.1.128Columnf10GMUXCH2DDFiberTypeRemoteread-onlycurrentLocal FRM220-TM-10GMUX card CH2 D/D information: Fiber Type
1.3.6.1.4.1.4756.20.701.20.1.129Columnf10GMUXCH2DDWaveLenRemoteread-onlycurrentLocal FRM220-TM-10GMUX card CH2 D/D information: Wave length
1.3.6.1.4.1.4756.20.701.20.1.130Columnf10GMUXCH2DDWaveLen2Remoteread-onlycurrentLocal FRM220-TM-10GMUX card CH2 D/D information: Wave length 2
1.3.6.1.4.1.4756.20.701.20.1.131Columnf10GMUXCH2DDLinkLenRemoteread-onlycurrentLocal FRM220-TM-10GMUX card CH2 D/D information: Link length
1.3.6.1.4.1.4756.20.701.20.1.132Columnf10GMUXCH2DDLenUnitRemoteread-onlycurrentRemote FRM220-10GMUX card CH2 D/D information: Length Unit
1.3.6.1.4.1.4756.20.701.20.1.133Columnf10GMUXCH2DDRxSensRemoteread-onlycurrentLocal FRM220-TM-10GMUX card CH2 D/D information: Rx Sensitivity
1.3.6.1.4.1.4756.20.701.20.1.134Columnf10GMUXCH2DDTxPWRRemoteread-onlycurrentLocal FRM220-TM-10GMUX card CH2 D/D information: Tx power
1.3.6.1.4.1.4756.20.701.20.1.135Columnf10GMUXCH2DDRxPWRRemoteread-onlycurrentLocal FRM220-TM-10GMUX card CH2 D/D information: Rx power
1.3.6.1.4.1.4756.20.701.20.1.136Columnf10GMUXCH2DDTempRemoteread-onlycurrentLocal FRM220-TM-10GMUX card CH2 D/D information: Temperature in degree C
1.3.6.1.4.1.4756.20.701.20.1.137Columnf10GMUXCH2SupplyVolRemoteread-onlycurrentLocal FRM220-TM-10GMUX card CH2 D/D information: SupplyVol
1.3.6.1.4.1.4756.20.701.20.1.138Columnf10GMUXCH2TxLaserBiasRemoteread-onlycurrentLocal FRM220-TM-10GMUX card CH2 D/D information: Tx LaserBias
1.3.6.1.4.1.4756.20.701.20.1.139Columnf10GMUXCH3DDVendorRemoteread-onlycurrentLocal FRM220-TM-10GMUX card CH3 D/D information: Vendor name
1.3.6.1.4.1.4756.20.701.20.1.140Columnf10GMUXCH3DDPartNoRemoteread-onlycurrentLocal FRM220-TM-10GMUX card CH3 D/D information: Vendor part number
1.3.6.1.4.1.4756.20.701.20.1.141Columnf10GMUXCH3DDVendorSNRemoteread-onlycurrentLocal FRM220-TM-10GMUX card CH3 D/D information: Vendor SN
1.3.6.1.4.1.4756.20.701.20.1.142Columnf10GMUXCH3DDFiberTypeRemoteread-onlycurrentLocal FRM220-TM-10GMUX card CH3 D/D information: Fiber Type
1.3.6.1.4.1.4756.20.701.20.1.143Columnf10GMUXCH3DDWaveLenRemoteread-onlycurrentLocal FRM220-TM-10GMUX card CH3 D/D information: Wave length
1.3.6.1.4.1.4756.20.701.20.1.144Columnf10GMUXCH3DDWaveLen2Remoteread-onlycurrentLocal FRM220-TM-10GMUX card CH3 D/D information: Wave length 2
1.3.6.1.4.1.4756.20.701.20.1.145Columnf10GMUXCH3DDLinkLenRemoteread-onlycurrentLocal FRM220-TM-10GMUX card CH3 D/D information: Link length
1.3.6.1.4.1.4756.20.701.20.1.146Columnf10GMUXCH3DDLenUnitRemoteread-onlycurrentRemote FRM220-10GMUX card CH3 D/D information: Length Unit
1.3.6.1.4.1.4756.20.701.20.1.147Columnf10GMUXCH3DDRxSensRemoteread-onlycurrentLocal FRM220-TM-10GMUX card CH3 D/D information: Rx Sensitivity
1.3.6.1.4.1.4756.20.701.20.1.148Columnf10GMUXCH3DDTxPWRRemoteread-onlycurrentLocal FRM220-TM-10GMUX card CH3 D/D information: Tx power
1.3.6.1.4.1.4756.20.701.20.1.149Columnf10GMUXCH3DDRxPWRRemoteread-onlycurrentLocal FRM220-TM-10GMUX card CH3 D/D information: Rx power
1.3.6.1.4.1.4756.20.701.20.1.150Columnf10GMUXCH3DDTempRemoteread-onlycurrentLocal FRM220-TM-10GMUX card CH3 D/D information: Temperature in degree C
1.3.6.1.4.1.4756.20.701.20.1.151Columnf10GMUXCH3SupplyVolRemoteread-onlycurrentLocal FRM220-TM-10GMUX card CH3 D/D information: SupplyVol
1.3.6.1.4.1.4756.20.701.20.1.152Columnf10GMUXCH3TxLaserBiasRemoteread-onlycurrentLocal FRM220-TM-10GMUX card CH3 D/D information: Tx LaserBias
1.3.6.1.4.1.4756.20.701.20.1.153Columnf10GMUXCH4DDVendorRemoteread-onlycurrentLocal FRM220-TM-10GMUX card CH4 D/D information: Vendor name
1.3.6.1.4.1.4756.20.701.20.1.154Columnf10GMUXCH4DDPartNoRemoteread-onlycurrentLocal FRM220-TM-10GMUX card CH4 D/D information: Vendor part number
1.3.6.1.4.1.4756.20.701.20.1.155Columnf10GMUXCH4DDVendorSNRemoteread-onlycurrentLocal FRM220-TM-10GMUX card CH4 D/D information: Vendor SN
1.3.6.1.4.1.4756.20.701.20.1.156Columnf10GMUXCH4DDFiberTypeRemoteread-onlycurrentLocal FRM220-TM-10GMUX card CH4 D/D information: Fiber Type
1.3.6.1.4.1.4756.20.701.20.1.157Columnf10GMUXCH4DDWaveLenRemoteread-onlycurrentLocal FRM220-TM-10GMUX card CH4 D/D information: Wave length
1.3.6.1.4.1.4756.20.701.20.1.158Columnf10GMUXCH4DDWaveLen2Remoteread-onlycurrentLocal FRM220-TM-10GMUX card CH4 D/D information: Wave length 2
1.3.6.1.4.1.4756.20.701.20.1.159Columnf10GMUXCH4DDLinkLenRemoteread-onlycurrentLocal FRM220-TM-10GMUX card CH4 D/D information: Link length
1.3.6.1.4.1.4756.20.701.20.1.160Columnf10GMUXCH4DDLenUnitRemoteread-onlycurrentRemote FRM220-10GMUX card CH4 D/D information: Length Unit
1.3.6.1.4.1.4756.20.701.20.1.161Columnf10GMUXCH4DDRxSensRemoteread-onlycurrentLocal FRM220-TM-10GMUX card CH4 D/D information: Rx Sensitivity
1.3.6.1.4.1.4756.20.701.20.1.162Columnf10GMUXCH4DDTxPWRRemoteread-onlycurrentLocal FRM220-TM-10GMUX card CH4 D/D information: Tx power
1.3.6.1.4.1.4756.20.701.20.1.163Columnf10GMUXCH4DDRxPWRRemoteread-onlycurrentLocal FRM220-TM-10GMUX card CH4 D/D information: Rx power
1.3.6.1.4.1.4756.20.701.20.1.164Columnf10GMUXCH4DDTempRemoteread-onlycurrentLocal FRM220-TM-10GMUX card CH4 D/D information: Temperature in degree C
1.3.6.1.4.1.4756.20.701.20.1.165Columnf10GMUXCH4SupplyVolRemoteread-onlycurrentLocal FRM220-TM-10GMUX card CH4 D/D information: SupplyVol
1.3.6.1.4.1.4756.20.701.20.1.166Columnf10GMUXCH4TxLaserBiasRemoteread-onlycurrentLocal FRM220-TM-10GMUX card CH4 D/D information: Tx LaserBias
1.3.6.1.4.1.4756.20.701.20.1.167Columnf10GMUXCH5DDVendorRemoteread-onlycurrentLocal FRM220-TM-10GMUX card CH5 D/D information: Vendor name
1.3.6.1.4.1.4756.20.701.20.1.168Columnf10GMUXCH5DDPartNoRemoteread-onlycurrentLocal FRM220-TM-10GMUX card CH5 D/D information: Vendor part number
1.3.6.1.4.1.4756.20.701.20.1.169Columnf10GMUXCH5DDVendorSNRemoteread-onlycurrentLocal FRM220-TM-10GMUX card CH5 D/D information: Vendor SN
1.3.6.1.4.1.4756.20.701.20.1.170Columnf10GMUXCH5DDFiberTypeRemoteread-onlycurrentLocal FRM220-TM-10GMUX card CH5 D/D information: Fiber Type
1.3.6.1.4.1.4756.20.701.20.1.171Columnf10GMUXCH5DDWaveLenRemoteread-onlycurrentLocal FRM220-TM-10GMUX card CH5 D/D information: Wave length
1.3.6.1.4.1.4756.20.701.20.1.172Columnf10GMUXCH5DDWaveLen2Remoteread-onlycurrentLocal FRM220-TM-10GMUX card CH5 D/D information: Wave length 2
1.3.6.1.4.1.4756.20.701.20.1.173Columnf10GMUXCH5DDLinkLenRemoteread-onlycurrentLocal FRM220-TM-10GMUX card CH5 D/D information: Link length
1.3.6.1.4.1.4756.20.701.20.1.174Columnf10GMUXCH5DDLenUnitRemoteread-onlycurrentRemote FRM220-10GMUX card CH5 D/D information: Length Unit
1.3.6.1.4.1.4756.20.701.20.1.175Columnf10GMUXCH5DDRxSensRemoteread-onlycurrentLocal FRM220-TM-10GMUX card CH5 D/D information: Rx Sensitivity
1.3.6.1.4.1.4756.20.701.20.1.176Columnf10GMUXCH5DDTxPWRRemoteread-onlycurrentLocal FRM220-TM-10GMUX card CH5 D/D information: Tx power
1.3.6.1.4.1.4756.20.701.20.1.177Columnf10GMUXCH5DDRxPWRRemoteread-onlycurrentLocal FRM220-TM-10GMUX card CH5 D/D information: Rx power
1.3.6.1.4.1.4756.20.701.20.1.178Columnf10GMUXCH5DDTempRemoteread-onlycurrentLocal FRM220-TM-10GMUX card CH5 D/D information: Temperature in degree C
1.3.6.1.4.1.4756.20.701.20.1.179Columnf10GMUXCH5SupplyVolRemoteread-onlycurrentLocal FRM220-TM-10GMUX card CH5 D/D information: SupplyVol
1.3.6.1.4.1.4756.20.701.20.1.180Columnf10GMUXCH5TxLaserBiasRemoteread-onlycurrentLocal FRM220-TM-10GMUX card CH5 D/D information: Tx LaserBias
1.3.6.1.4.1.4756.20.701.20.1.181Columnf10GMUXCH6DDVendorRemoteread-onlycurrentLocal FRM220-TM-10GMUX card CH6 D/D information: Vendor name
1.3.6.1.4.1.4756.20.701.20.1.182Columnf10GMUXCH6DDPartNoRemoteread-onlycurrentLocal FRM220-TM-10GMUX card CH6 D/D information: Vendor part number
1.3.6.1.4.1.4756.20.701.20.1.183Columnf10GMUXCH6DDVendorSNRemoteread-onlycurrentLocal FRM220-TM-10GMUX card CH6 D/D information: Vendor SN
1.3.6.1.4.1.4756.20.701.20.1.184Columnf10GMUXCH6DDFiberTypeRemoteread-onlycurrentLocal FRM220-TM-10GMUX card CH6 D/D information: Fiber Type
1.3.6.1.4.1.4756.20.701.20.1.185Columnf10GMUXCH6DDWaveLenRemoteread-onlycurrentLocal FRM220-TM-10GMUX card CH6 D/D information: Wave length
1.3.6.1.4.1.4756.20.701.20.1.186Columnf10GMUXCH6DDWaveLen2Remoteread-onlycurrentLocal FRM220-TM-10GMUX card CH6 D/D information: Wave length 2
1.3.6.1.4.1.4756.20.701.20.1.187Columnf10GMUXCH6DDLinkLenRemoteread-onlycurrentLocal FRM220-TM-10GMUX card CH6 D/D information: Link length
1.3.6.1.4.1.4756.20.701.20.1.188Columnf10GMUXCH6DDLenUnitRemoteread-onlycurrentRemote FRM220-10GMUX card CH6 D/D information: Length Unit
1.3.6.1.4.1.4756.20.701.20.1.189Columnf10GMUXCH6DDRxSensRemoteread-onlycurrentLocal FRM220-TM-10GMUX card CH6 D/D information: Rx Sensitivity
1.3.6.1.4.1.4756.20.701.20.1.190Columnf10GMUXCH6DDTxPWRRemoteread-onlycurrentLocal FRM220-TM-10GMUX card CH6 D/D information: Tx power
1.3.6.1.4.1.4756.20.701.20.1.191Columnf10GMUXCH6DDRxPWRRemoteread-onlycurrentLocal FRM220-TM-10GMUX card CH6 D/D information: Rx power
1.3.6.1.4.1.4756.20.701.20.1.192Columnf10GMUXCH6DDTempRemoteread-onlycurrentLocal FRM220-TM-10GMUX card CH6 D/D information: Temperature in degree C
1.3.6.1.4.1.4756.20.701.20.1.193Columnf10GMUXCH6SupplyVolRemoteread-onlycurrentLocal FRM220-TM-10GMUX card CH6 D/D information: SupplyVol
1.3.6.1.4.1.4756.20.701.20.1.194Columnf10GMUXCH6TxLaserBiasRemoteread-onlycurrentLocal FRM220-TM-10GMUX card CH6 D/D information: Tx LaserBias
1.3.6.1.4.1.4756.20.701.20.1.195Columnf10GMUXCH7DDVendorRemoteread-onlycurrentLocal FRM220-TM-10GMUX card CH7 D/D information: Vendor name
1.3.6.1.4.1.4756.20.701.20.1.196Columnf10GMUXCH7DDPartNoRemoteread-onlycurrentLocal FRM220-TM-10GMUX card CH7 D/D information: Vendor part number
1.3.6.1.4.1.4756.20.701.20.1.197Columnf10GMUXCH7DDVendorSNRemoteread-onlycurrentLocal FRM220-TM-10GMUX card CH7 D/D information: Vendor SN
1.3.6.1.4.1.4756.20.701.20.1.198Columnf10GMUXCH7DDFiberTypeRemoteread-onlycurrentLocal FRM220-TM-10GMUX card CH7 D/D information: Fiber Type
1.3.6.1.4.1.4756.20.701.20.1.199Columnf10GMUXCH7DDWaveLenRemoteread-onlycurrentLocal FRM220-TM-10GMUX card CH7 D/D information: Wave length
1.3.6.1.4.1.4756.20.701.20.1.200Columnf10GMUXCH7DDWaveLen2Remoteread-onlycurrentLocal FRM220-TM-10GMUX card CH7 D/D information: Wave length 2
1.3.6.1.4.1.4756.20.701.20.1.201Columnf10GMUXCH7DDLinkLenRemoteread-onlycurrentLocal FRM220-TM-10GMUX card CH7 D/D information: Link length
1.3.6.1.4.1.4756.20.701.20.1.202Columnf10GMUXCH7DDLenUnitRemoteread-onlycurrentRemote FRM220-10GMUX card CH7 D/D information: Length Unit
1.3.6.1.4.1.4756.20.701.20.1.203Columnf10GMUXCH7DDRxSensRemoteread-onlycurrentLocal FRM220-TM-10GMUX card CH7 D/D information: Rx Sensitivity
1.3.6.1.4.1.4756.20.701.20.1.204Columnf10GMUXCH7DDTxPWRRemoteread-onlycurrentLocal FRM220-TM-10GMUX card CH7 D/D information: Tx power
1.3.6.1.4.1.4756.20.701.20.1.205Columnf10GMUXCH7DDRxPWRRemoteread-onlycurrentLocal FRM220-TM-10GMUX card CH7 D/D information: Rx power
1.3.6.1.4.1.4756.20.701.20.1.206Columnf10GMUXCH7DDTempRemoteread-onlycurrentLocal FRM220-TM-10GMUX card CH7 D/D information: Temperature in degree C
1.3.6.1.4.1.4756.20.701.20.1.207Columnf10GMUXCH7SupplyVolRemoteread-onlycurrentLocal FRM220-TM-10GMUX card CH7 D/D information: SupplyVol
1.3.6.1.4.1.4756.20.701.20.1.208Columnf10GMUXCH7TxLaserBiasRemoteread-onlycurrentLocal FRM220-TM-10GMUX card CH7 D/D information: Tx LaserBias
1.3.6.1.4.1.4756.20.701.20.1.209Columnf10GMUXDeviceActiveRemoteread-onlycurrentLocal FRM220-TM-10GMUX card active: 0:Inactive 1:Active
1.3.6.1.4.1.4756.20.701.20.1.210Columnf10GMUXClrCVCntsRemoteread-writecurrentClear local device card CV IN/OUT counters: 0:No action 1:Action
1.3.6.1.4.1.4756.20.701.20.1.211Columnf10GMUXTunableLinechORfreqRemoteread-writecurrentLocal FRM220-TM-10GMUX card Tunable Line chORfreq Mode. 0: Channel 1: Frequency
1.3.6.1.4.1.4756.20.701.20.1.212Columnf10GMUXTunableLineChannelRemoteread-writecurrentLocal FRM220-TM-10GMUX card Tunable Line Channel setting.
1.3.6.1.4.1.4756.20.701.20.1.213Columnf10GMUXTunableLineFrequencyRemoteread-writecurrentLocal FRM220-TM-10GMUX card Tunable Line Frequency setting.
1.3.6.1.4.1.4756.20.701.20.1.214Columnf10GMUXPowerLedRemoteread-onlycurrentLocal FRM220-TM-10GMUX card Powe Led. 0:ON (Power ON) 1:Flash (Standby; 1s ON/1s OFF)
1.3.6.1.4.1.4756.20.701.20.1.215Columnf10GMUXSystemLedRemoteread-onlycurrentLocal FRM220-TM-10GMUX card Syetem Led. 0:OFF 1:Link up 2:ON
1.3.6.1.4.1.4756.20.701.20.1.216Columnf10GMUXAlarmLedRemoteread-onlycurrentLocal FRM220-TM-10GMUX card Alarm Led. 0:OFF 1:ON
1.3.6.1.4.1.4756.20.701.20.1.217Columnf10GMUXLFPTLedRemoteread-onlycurrentLocal FRM220-TM-10GMUX card LFPT Led. 0:OFF 1:ON
1.3.6.1.4.1.4756.20.701.20.1.218Columnf10GMUXLineLedRemoteread-onlycurrentLocal FRM220-TM-10GMUX card Line Led. 0:OFF(Link Down) 1:link up (On: 0.5s, Off: 0.5s) 2:LB (On: 1s, Off: 1s) 3:ON (0.5s ON/0.5s OFF)
1.3.6.1.4.1.4756.20.701.20.1.219Columnf10GMUXCH1LedRemoteread-onlycurrentLocal FRM220-TM-10GMUX card CH1 Led. 0:OFF(Link Down) 1:link up (On: 0.5s, Off: 0.5s) 2:LB (On: 1s, Off: 1s) 3:ON (0.5s ON/0.5s OFF)
1.3.6.1.4.1.4756.20.701.20.1.220Columnf10GMUXCH2LedRemoteread-onlycurrentLocal FRM220-TM-10GMUX card CH2 Led. 0:OFF(Link Down) 1:link up (On: 0.5s, Off: 0.5s) 2:LB (On: 1s, Off: 1s) 3:ON (0.5s ON/0.5s OFF)
1.3.6.1.4.1.4756.20.701.20.1.221Columnf10GMUXCH3LedRemoteread-onlycurrentLocal FRM220-TM-10GMUX card CH3 Led. 0:OFF(Link Down) 1:link up (On: 0.5s, Off: 0.5s) 2:LB (On: 1s, Off: 1s) 3:ON (0.5s ON/0.5s OFF)
1.3.6.1.4.1.4756.20.701.20.1.222Columnf10GMUXCH4LedRemoteread-onlycurrentLocal FRM220-TM-10GMUX card CH4 Led. 0:OFF(Link Down) 1:link up (On: 0.5s, Off: 0.5s) 2:LB (On: 1s, Off: 1s) 3:ON (0.5s ON/0.5s OFF)
1.3.6.1.4.1.4756.20.701.20.1.223Columnf10GMUXCH5LedRemoteread-onlycurrentLocal FRM220-TM-10GMUX card CH5 Led. 0:OFF(Link Down) 1:link up (On: 0.5s, Off: 0.5s) 2:LB (On: 1s, Off: 1s) 3:ON (0.5s ON/0.5s OFF)
1.3.6.1.4.1.4756.20.701.20.1.224Columnf10GMUXCH6LedRemoteread-onlycurrentLocal FRM220-TM-10GMUX card CH6 Led. 0:OFF(Link Down) 1:link up (On: 0.5s, Off: 0.5s) 2:LB (On: 1s, Off: 1s) 3:ON (0.5s ON/0.5s OFF)
1.3.6.1.4.1.4756.20.701.20.1.225Columnf10GMUXCH7LedRemoteread-onlycurrentLocal FRM220-TM-10GMUX card CH7 Led. 0:OFF(Link Down) 1:link up (On: 0.5s, Off: 0.5s) 2:LB (On: 1s, Off: 1s) 3:ON (0.5s ON/0.5s OFF)
1.3.6.1.4.1.4756.20.710Nodef100GE2QCards
1.3.6.1.4.1.4756.20.710.20Tablef100GE2QTablenot-accessiblecurrentA list of local Access 100G Line Card entries. The number of entries is Access 100G-No-L.
1.3.6.1.4.1.4756.20.710.20.1Rowf100GE2QEntrynot-accessiblecurrentAn entry containing management information applicable to a particular local Access 100G Line Card.
1.3.6.1.4.1.4756.20.710.20.1.1Columnf100GE2QChassisIndexread-onlycurrentA unique value for each local card. It is the chassis location number.
1.3.6.1.4.1.4756.20.710.20.1.2Columnf100GE2QSlotIndexread-onlycurrentA unique value for each local card. It is the slot location number.
1.3.6.1.4.1.4756.20.710.20.1.3Columnf100GE2QCardHWVerread-onlycurrentLocal FRM220-100GE-2Q Line Card hardware version x.xxx
1.3.6.1.4.1.4756.20.710.20.1.4Columnf100GE2QCardFWVerread-onlycurrentLocal FRM220-100GE-2Q Line Card firmware version x.xxx
1.3.6.1.4.1.4756.20.710.20.1.5Columnf100GE2QCardCPLDVerread-onlycurrentLocal FRM220-100GE-2Q Line Card CPLD version x.xxx
1.3.6.1.4.1.4756.20.710.20.1.6Columnf100GE2QCardFPGAVerread-onlycurrentLocal FRM220-100GE-2Q Line Card FPGA version x.xxx
1.3.6.1.4.1.4756.20.710.20.1.7Columnf100GE2QPortResetread-writecurrentLocal FRM220-100GE-2Q Line Card Port Reset feature: 0:Inactive 1:Active
1.3.6.1.4.1.4756.20.710.20.1.8Columnf100GE2QSetDefaultread-writecurrentLocal FRM220-100GE-2Q Line Card Set to Default function: 0:Inactive 1:Active
1.3.6.1.4.1.4756.20.710.20.1.9Columnf100GE2QLinePresentread-onlycurrentLocal FRM220-100GE-2Q Line Card Line Fiber Port Present: 0:NO 1:YES
1.3.6.1.4.1.4756.20.710.20.1.10Columnf100GE2QClientPresentread-onlycurrentLocal FRM220-100GE-2Q Line Card Client Fiber Port Present: 0:NO 1:YES
1.3.6.1.4.1.4756.20.710.20.1.11Columnf100GE2QLineLinkread-onlycurrentLocal FRM220-100GE-2Q Line Card Line Fiber Port Link Status: 0:Down 1:Up
1.3.6.1.4.1.4756.20.710.20.1.12Columnf100GE2QClientLinkread-onlycurrentLocal FRM220-100GE-2Q Line Card Client Fiber Port Link Status: 0:Down 1:Up
1.3.6.1.4.1.4756.20.710.20.1.13Columnf100GE2QLine1CDRLockread-onlycurrentLocal FRM220-100GE-2Q Line Card Line1 Fiber Port CDR Lock Status: 0:Not Locked 1:Locked
1.3.6.1.4.1.4756.20.710.20.1.14Columnf100GE2QLine2CDRLockread-onlycurrentLocal FRM220-100GE-2Q Line Card Line2 Fiber Port CDR Lock Status: 0:Not Locked 1:Locked
1.3.6.1.4.1.4756.20.710.20.1.15Columnf100GE2QLine3CDRLockread-onlycurrentLocal FRM220-100GE-2Q Line Card Line3 Fiber Port CDR Lock Status: 0:Not Locked 1:Locked
1.3.6.1.4.1.4756.20.710.20.1.16Columnf100GE2QLine4CDRLockread-onlycurrentLocal FRM220-100GE-2Q Line Card Line4 Fiber Port CDR Lock Status: 0:Not Locked 1:Locked
1.3.6.1.4.1.4756.20.710.20.1.17Columnf100GE2QClient1CDRLockread-onlycurrentLocal FRM220-100GE-2Q Line Card Client1 Fiber Port CDR Lock Status: 0:Not Locked 1:Locked
1.3.6.1.4.1.4756.20.710.20.1.18Columnf100GE2QClient2CDRLockread-onlycurrentLocal FRM220-100GE-2Q Line Card Client2 Fiber Port CDR Lock Status: 0:Not Locked 1:Locked
1.3.6.1.4.1.4756.20.710.20.1.19Columnf100GE2QClient3CDRLockread-onlycurrentLocal FRM220-100GE-2Q Line Card Client3 Fiber Port CDR Lock Status: 0:Not Locked 1:Locked
1.3.6.1.4.1.4756.20.710.20.1.20Columnf100GE2QClient4CDRLockread-onlycurrentLocal FRM220-100GE-2Q Line Card Client4 Fiber Port CDR Lock Status: 0:Not Locked 1:Locked
1.3.6.1.4.1.4756.20.710.20.1.21Columnf100GE2QLine1TxFaultread-onlycurrentLocal FRM220-100GE-2Q Line Card Line1 Fiber Port Transmit Fault Status: 0:Normal 1:Failure
1.3.6.1.4.1.4756.20.710.20.1.22Columnf100GE2QLine2TxFaultread-onlycurrentLocal FRM220-100GE-2Q Line Card Line2 Fiber Port Transmit Fault Status: 0:Normal 1:Failure
1.3.6.1.4.1.4756.20.710.20.1.23Columnf100GE2QLine3TxFaultread-onlycurrentLocal FRM220-100GE-2Q Line Card Line3 Fiber Port Transmit Fault Status: 0:Normal 1:Failure
1.3.6.1.4.1.4756.20.710.20.1.24Columnf100GE2QLine4TxFaultread-onlycurrentLocal FRM220-100GE-2Q Line Card Line4 Fiber Port Transmit Fault Status: 0:Normal 1:Failure
1.3.6.1.4.1.4756.20.710.20.1.25Columnf100GE2QClient1TxFaultread-onlycurrentLocal FRM220-100GE-2Q Line Card Client1 Fiber Port Transmit Fault Status: 0:Normal 1:Failure
1.3.6.1.4.1.4756.20.710.20.1.26Columnf100GE2QClient2TxFaultread-onlycurrentLocal FRM220-100GE-2Q Line Card Client2 Fiber Port Transmit Fault Status: 0:Normal 1:Failure
1.3.6.1.4.1.4756.20.710.20.1.27Columnf100GE2QClient3TxFaultread-onlycurrentLocal FRM220-100GE-2Q Line Card Client3 Fiber Port Transmit Fault Status: 0:Normal 1:Failure
1.3.6.1.4.1.4756.20.710.20.1.28Columnf100GE2QClient4TxFaultread-onlycurrentLocal FRM220-100GE-2Q Line Card Client4 Fiber Port Transmit Fault Status: 0:Normal 1:Failure
1.3.6.1.4.1.4756.20.710.20.1.29Columnf100GE2QPortActiveread-writecurrentLocal FRM220-100GE-2Q Line Card Port Active: 0:Disable 1:Enable
1.3.6.1.4.1.4756.20.710.20.1.30Columnf100GE2QLineActiveread-writecurrentLocal FRM220-100GE-2Q Line Card Line Active: 0:Disable 1:Enable
1.3.6.1.4.1.4756.20.710.20.1.31Columnf100GE2QClientActiveread-writecurrentLocal FRM220-100GE-2Q Line Card Client Active: 0:Disable 1:Enable
1.3.6.1.4.1.4756.20.710.20.1.32Columnf100GE2QDataRateStsread-onlycurrentLocal FRM220-100GE-2Q Line Card Data Rate Status.
1.3.6.1.4.1.4756.20.710.20.1.33Columnf100GE2QDataRateread-writecurrentLocal FRM220-100GE-2Q Line Card Data Rate setting: 0:Ethernet 100GBaseR (PCS) 1:Ethernet 40GBaseR (PCS)
1.3.6.1.4.1.4756.20.710.20.1.34Columnf100GE2QFECread-writecurrentLocal FRM220-100GE-2Q Line Card Data Rate setting: 0:Disable 1:Line side 2:Client side 3:Both side
1.3.6.1.4.1.4756.20.710.20.1.35Columnf100GE2QLineLBTread-writecurrentLocal FRM220-100GE-2Q Line Card Line LoopBack Test function setting: 0:Disable 1:Enable
1.3.6.1.4.1.4756.20.710.20.1.36Columnf100GE2QClientLBTread-writecurrentLocal FRM220-100GE-2Q Line Card Client LoopBack Test function setting: 0:Disable 1:Enable
1.3.6.1.4.1.4756.20.710.20.1.37Columnf100GE2QLineALSread-writecurrentLocal FRM220-100GE-2Q Line Card Line Auto Laser Shutdown setting: 0:Disable 1:Enable
1.3.6.1.4.1.4756.20.710.20.1.38Columnf100GE2QClientALSread-writecurrentLocal FRM220-100GE-2Q Line Card Client Auto Laser Shutdown setting: 0:Disable 1:Enable
1.3.6.1.4.1.4756.20.710.20.1.39Columnf100GE2QQSFPLFPread-writecurrentLocal FRM220-100GE-2Q Line Card both of Line and Client Loss Propagation setting: 0:Disable 1:Line 2:Client 3:Both
1.3.6.1.4.1.4756.20.710.20.1.40Columnf100GE2QLineTxPacketread-onlycurrentLocal FRM220-100GE-2Q Line Card Line Tx Packet.
1.3.6.1.4.1.4756.20.710.20.1.41Columnf100GE2QLineRxPacketread-onlycurrentLocal FRM220-100GE-2Q Line Card Line Rx Packet.
1.3.6.1.4.1.4756.20.710.20.1.42Columnf100GE2QLineErrPacketread-onlycurrentLocal FRM220-100GE-2Q Line Card Line Error Packet.
1.3.6.1.4.1.4756.20.710.20.1.43Columnf100GE2QClientTxPacketread-onlycurrentLocal FRM220-100GE-2Q Line Card Client Tx Packet.
1.3.6.1.4.1.4756.20.710.20.1.44Columnf100GE2QClientRxPacketread-onlycurrentLocal FRM220-100GE-2Q Line Card Client Rx Packet.
1.3.6.1.4.1.4756.20.710.20.1.45Columnf100GE2QClientErrPacketread-onlycurrentLocal FRM220-100GE-2Q Line Card Client Error Packet.
1.3.6.1.4.1.4756.20.710.20.1.46Columnf100GE2QLineBERTread-writecurrentLocal FRM220-100GE-2Q Line Card Line BERT setting: 0:All Disable 1:Packet Transmit Enable 2:Packet Receive Enable 3:All Enable
1.3.6.1.4.1.4756.20.710.20.1.47Columnf100GE2QClientBERTread-writecurrentLocal FRM220-100GE-2Q Line Card Client BERT setting: 0:All Disable 1:Packet Transmit Enable 2:Packet Receive Enable 3:All Enable
1.3.6.1.4.1.4756.20.710.20.1.48Columnf100GE2QClrBERTCntread-writecurrentClear local device card Bert Counters: 0:No action 1:Action
1.3.6.1.4.1.4756.20.710.20.1.49Columnf100GE2QLineVendorNameread-onlycurrentLocal FRM220-100GE-2Q Line Card Line Vender Name.
1.3.6.1.4.1.4756.20.710.20.1.50Columnf100GE2QLinePartNoread-onlycurrentLocal FRM220-100GE-2Q Line Card Line Part Number.
1.3.6.1.4.1.4756.20.710.20.1.51Columnf100GE2QLineSerialNumberread-onlycurrentLocal FRM220-100GE-2Q Line Card Line Part Number.
1.3.6.1.4.1.4756.20.710.20.1.52Columnf100GE2QLineTransceiverread-onlycurrent100G or 40G QSFP Plus Transceiver. 40G-Active-Cable-XLPPI 40GBASE-LR4 40GBASE-SR4 40GBASE-CR4 10GBASE-SR 10GBASE-LR 10GBASE-LRM Unspecified 100G AOC or 25GAUI …
1.3.6.1.4.1.4756.20.710.20.1.53Columnf100GE2QLineTransceiver2read-onlycurrent100G or 40G QSFP Plus Transceiver2. 40G OTN (OTU3B/OTU3C) OC 48, short reach OC 48, intermediate reach OC 48, long reach
1.3.6.1.4.1.4756.20.710.20.1.54Columnf100GE2QLineTransceiver3read-onlycurrent100G or 40G QSFP Plus Transceiver3. SAS 12.0G SAS 24.0G SAS 3.0G SAS 6.0G
1.3.6.1.4.1.4756.20.710.20.1.55Columnf100GE2QLineConnectorTyperead-onlycurrent100G LINE Conncetor Type. Unknown SC FC-Style-1-copper-connector FC-Style-2-copper-connector BNC/TNC FC-coax-headers Fiberjack LC MT-RJ MU SG Optical-Pigtail M…
1.3.6.1.4.1.4756.20.710.20.1.56Columnf100GE2QLineWaveLength1read-onlycurrentLocal FRM220-100GE-2Q Line Card Line Wave Length 1.
1.3.6.1.4.1.4756.20.710.20.1.57Columnf100GE2QLineWaveLength2read-onlycurrentLocal FRM220-100GE-2Q Line Card Line Wave Length 2.
1.3.6.1.4.1.4756.20.710.20.1.58Columnf100GE2QLineLinkLengthread-onlycurrentLocal FRM220-100GE-2Q Line Card Line Link Length.
1.3.6.1.4.1.4756.20.710.20.1.59Columnf100GE2QLineNominalBitRateread-onlycurrentLocal FRM220-100GE-2Q Line Card Line Nominal Bit Rate.
1.3.6.1.4.1.4756.20.710.20.1.60Columnf100GE2QLineTempread-onlycurrentLocal FRM220-100GE-2Q Line Card Line Temperature.
1.3.6.1.4.1.4756.20.710.20.1.61Columnf100GE2QLineSupplyVolread-onlycurrentLocal FRM220-100GE-2Q Line Card Line Supply Voltage.
1.3.6.1.4.1.4756.20.710.20.1.62Columnf100GE2QLineTxMaxPowerread-onlycurrentLocal FRM220-100GE-2Q Line Card Line Tx Max Power.
1.3.6.1.4.1.4756.20.710.20.1.63Columnf100GE2QLineRxMaxPowerread-onlycurrentLocal FRM220-100GE-2Q Line Card Line Rx Max Power.
1.3.6.1.4.1.4756.20.710.20.1.64Columnf100GE2QLinePowerClassread-onlycurrentLocal FRM220-100GE-2Q Line Card Line Power Class.
1.3.6.1.4.1.4756.20.710.20.1.65Columnf100GE2QLine1TxPowerread-onlycurrentLocal FRM220-100GE-2Q Line Card Line1 Transmit Power.
1.3.6.1.4.1.4756.20.710.20.1.66Columnf100GE2QLine1RxPowerread-onlycurrentLocal FRM220-100GE-2Q Line Card Line1 Receive Power.
1.3.6.1.4.1.4756.20.710.20.1.67Columnf100GE2QLine1TxLaserBiasread-onlycurrentLocal FRM220-100GE-2Q Line Card Line1 Transmit Laser BIAS.
1.3.6.1.4.1.4756.20.710.20.1.68Columnf100GE2QLine2TxPowerread-onlycurrentLocal FRM220-100GE-2Q Line Card Line2 Transmit Power.
1.3.6.1.4.1.4756.20.710.20.1.69Columnf100GE2QLine2RxPowerread-onlycurrentLocal FRM220-100GE-2Q Line Card Line2 Receive Power.
1.3.6.1.4.1.4756.20.710.20.1.70Columnf100GE2QLine2TxLaserBiasread-onlycurrentLocal FRM220-100GE-2Q Line Card Line2 Transmit Laser BIAS.
1.3.6.1.4.1.4756.20.710.20.1.71Columnf100GE2QLine3TxPowerread-onlycurrentLocal FRM220-100GE-2Q Line Card Line3 Transmit Power.
1.3.6.1.4.1.4756.20.710.20.1.72Columnf100GE2QLine3RxPowerread-onlycurrentLocal FRM220-100GE-2Q Line Card Line3 Receive Power.
1.3.6.1.4.1.4756.20.710.20.1.73Columnf100GE2QLine3TxLaserBiasread-onlycurrentLocal FRM220-100GE-2Q Line Card Line3 Transmit Laser BIAS.
1.3.6.1.4.1.4756.20.710.20.1.74Columnf100GE2QLine4TxPowerread-onlycurrentLocal FRM220-100GE-2Q Line Card Line4 Transmit Power.
1.3.6.1.4.1.4756.20.710.20.1.75Columnf100GE2QLine4RxPowerread-onlycurrentLocal FRM220-100GE-2Q Line Card Line4 Receive Power.
1.3.6.1.4.1.4756.20.710.20.1.76Columnf100GE2QLine4TxLaserBiasread-onlycurrentLocal FRM220-100GE-2Q Line Card Line4 Transmit Laser BIAS.
1.3.6.1.4.1.4756.20.710.20.1.77Columnf100GE2QLineTxPowerSumread-onlycurrentLocal FRM220-100GE-2Q Line Card Line Tx Power Sum.
1.3.6.1.4.1.4756.20.710.20.1.78Columnf100GE2QLineRxPowerSumread-onlycurrentLocal FRM220-100GE-2Q Line Card Line Rx Power Sum.
1.3.6.1.4.1.4756.20.710.20.1.79Columnf100GE2QClientVendorNameread-onlycurrentLocal FRM220-100GE-2Q Line Card Client Vender Name.
1.3.6.1.4.1.4756.20.710.20.1.80Columnf100GE2QClientPartNoread-onlycurrentLocal FRM220-100GE-2Q Line Card Client Part Number.
1.3.6.1.4.1.4756.20.710.20.1.81Columnf100GE2QClientSerialNumberread-onlycurrentLocal FRM220-100GE-2Q Line Card Client Serial Number.
1.3.6.1.4.1.4756.20.710.20.1.82Columnf100GE2QClientTransceiverread-onlycurrent100G or 40G QSFP Plus Transceiver. 40G-Active-Cable-XLPPI 40GBASE-LR4 40GBASE-SR4 40GBASE-CR4 10GBASE-SR 10GBASE-LR 10GBASE-LRM Unspecified 100G AOC or 25GAUI …
1.3.6.1.4.1.4756.20.710.20.1.83Columnf100GE2QClientTransceiver2read-onlycurrent100G or 40G QSFP Plus Transceiver2. 40G OTN (OTU3B/OTU3C) OC 48, short reach OC 48, intermediate reach OC 48, long reach
1.3.6.1.4.1.4756.20.710.20.1.84Columnf100GE2QClientTransceiver3read-onlycurrent100G or 40G QSFP Plus Transceiver3. SAS 12.0G SAS 24.0G SAS 3.0G SAS 6.0G
1.3.6.1.4.1.4756.20.710.20.1.85Columnf100GE2QClientConnectorTyperead-onlycurrent100G or 40G Client Conncetor Type. Unknown SC FC-Style-1-copper-connector FC-Style-2-copper-connector BNC/TNC FC-coax-headers Fiberjack LC MT-RJ MU SG Optical-…
1.3.6.1.4.1.4756.20.710.20.1.86Columnf100GE2QClientWaveLength1read-onlycurrentLocal FRM220-100GE-2Q Line Card Client Wave Length 1.
1.3.6.1.4.1.4756.20.710.20.1.87Columnf100GE2QClientWaveLength2read-onlycurrentLocal FRM220-100GE-2Q Line Card Client Wave Length 2.
1.3.6.1.4.1.4756.20.710.20.1.88Columnf100GE2QClientLinkLengthread-onlycurrentLocal FRM220-100GE-2Q Line Card Client Link Length.
1.3.6.1.4.1.4756.20.710.20.1.89Columnf100GE2QClientNominalBitRateread-onlycurrentLocal FRM220-100GE-2Q Line Card Client Nominal Bit Rate.
1.3.6.1.4.1.4756.20.710.20.1.90Columnf100GE2QClientTempread-onlycurrentLocal FRM220-100GE-2Q Line Card Client Temperature.
1.3.6.1.4.1.4756.20.710.20.1.91Columnf100GE2QClientSupplyVolread-onlycurrentLocal FRM220-100GE-2Q Line Card Client Supply Voltage.
1.3.6.1.4.1.4756.20.710.20.1.92Columnf100GE2QClientTxMaxPowerread-onlycurrentLocal FRM220-100GE-2Q Line Card Client Tx Max Power.
1.3.6.1.4.1.4756.20.710.20.1.93Columnf100GE2QClientRxMaxPowerread-onlycurrentLocal FRM220-100GE-2Q Line Card Client Rx Max Power.
1.3.6.1.4.1.4756.20.710.20.1.94Columnf100GE2QClientPowerClassread-onlycurrentLocal FRM220-100GE-2Q Line Card Client Power Class.
1.3.6.1.4.1.4756.20.710.20.1.95Columnf100GE2QClient1TxPowerread-onlycurrentLocal FRM220-100GE-2Q Line Card Client1 Transmit Power.
1.3.6.1.4.1.4756.20.710.20.1.96Columnf100GE2QClient1RxPowerread-onlycurrentLocal FRM220-100GE-2Q Line Card Client1 Receive Power.
1.3.6.1.4.1.4756.20.710.20.1.97Columnf100GE2QClient1TxLaserBiasread-onlycurrentLocal FRM220-100GE-2Q Line Card Client1 Transmit Laser BIAS.
1.3.6.1.4.1.4756.20.710.20.1.98Columnf100GE2QClient2TxPowerread-onlycurrentLocal FRM220-100GE-2Q Line Card Client2 Transmit Power.
1.3.6.1.4.1.4756.20.710.20.1.99Columnf100GE2QClient2RxPowerread-onlycurrentLocal FRM220-100GE-2Q Line Card Client2 Receive Power.
1.3.6.1.4.1.4756.20.710.20.1.100Columnf100GE2QClient2TxLaserBiasread-onlycurrentLocal FRM220-100GE-2Q Line Card Client2 Transmit Laser BIAS.
1.3.6.1.4.1.4756.20.710.20.1.101Columnf100GE2QClient3TxPowerread-onlycurrentLocal FRM220-100GE-2Q Line Card Client3 Transmit Power.
1.3.6.1.4.1.4756.20.710.20.1.102Columnf100GE2QClient3RxPowerread-onlycurrentLocal FRM220-100GE-2Q Line Card Client3 Receive Power.
1.3.6.1.4.1.4756.20.710.20.1.103Columnf100GE2QClient3TxLaserBiasread-onlycurrentLocal FRM220-100GE-2Q Line Card Client3 Transmit Laser BIAS.
1.3.6.1.4.1.4756.20.710.20.1.104Columnf100GE2QClient4TxPowerread-onlycurrentLocal FRM220-100GE-2Q Line Card Client4 Transmit Power.
1.3.6.1.4.1.4756.20.710.20.1.105Columnf100GE2QClient4RxPowerread-onlycurrentLocal FRM220-100GE-2Q Line Card Client4 Receive Power.
1.3.6.1.4.1.4756.20.710.20.1.106Columnf100GE2QClient4TxLaserBiasread-onlycurrentLocal FRM220-100GE-2Q Line Card Client4 Transmit Laser BIAS.
1.3.6.1.4.1.4756.20.710.20.1.107Columnf100GE2QClientTxPowerSumread-onlycurrentLocal FRM220-100GE-2Q Line Card Client Tx Power Sum.
1.3.6.1.4.1.4756.20.710.20.1.108Columnf100GE2QClientRxPowerSumread-onlycurrentLocal FRM220-100GE-2Q Line Card Client Rx Power Sum.
1.3.6.1.4.1.4756.20.710.20.1.109Columnf100GE2QLineLinkAlmread-writecurrentLocal FRM220-100GE-2Q Line Card Line Link Alarm setting: 0:Disable 1:Enable
1.3.6.1.4.1.4756.20.710.20.1.110Columnf100GE2QClientLinkAlmread-writecurrentLocal FRM220-100GE-2Q Line Card Client Link Alarm setting: 0:Disable 1:Enable
1.3.6.1.4.1.4756.20.710.20.1.111Columnf100GE2QLine1LockAlmread-writecurrentLocal FRM220-100GE-2Q Line Card Line 1 Lock Alarm setting: 0:Disable 1:Enable
1.3.6.1.4.1.4756.20.710.20.1.112Columnf100GE2QLine2LockAlmread-writecurrentLocal FRM220-100GE-2Q Line Card Line 2 Lock Alarm setting: 0:Disable 1:Enable
1.3.6.1.4.1.4756.20.710.20.1.113Columnf100GE2QLine3LockAlmread-writecurrentLocal FRM220-100GE-2Q Line Card Line 3 Lock Alarm setting: 0:Disable 1:Enable
1.3.6.1.4.1.4756.20.710.20.1.114Columnf100GE2QLine4LockAlmread-writecurrentLocal FRM220-100GE-2Q Line Card Line 4 Lock Alarm setting: 0:Disable 1:Enable
1.3.6.1.4.1.4756.20.710.20.1.115Columnf100GE2QClient1LockAlmread-writecurrentLocal FRM220-100GE-2Q Line Card Client 1 Lock Alarm setting: 0:Disable 1:Enable
1.3.6.1.4.1.4756.20.710.20.1.116Columnf100GE2QClient2LockAlmread-writecurrentLocal FRM220-100GE-2Q Line Card Client 2 Lock Alarm setting: 0:Disable 1:Enable
1.3.6.1.4.1.4756.20.710.20.1.117Columnf100GE2QClient3LockAlmread-writecurrentLocal FRM220-100GE-2Q Line Card Client 3 Lock Alarm setting: 0:Disable 1:Enable
1.3.6.1.4.1.4756.20.710.20.1.118Columnf100GE2QClient4LockAlmread-writecurrentLocal FRM220-100GE-2Q Line Card Client 4 Lock Alarm setting: 0:Disable 1:Enable
1.3.6.1.4.1.4756.20.720NodeoaboapCards
1.3.6.1.4.1.4756.20.720.20TableoaboapTablenot-accessiblecurrentA list of local oaboap card entries. The number of entries is accessEDFA-No-L.
1.3.6.1.4.1.4756.20.720.20.1RowoaboapEntrynot-accessiblecurrentAn entry containing management information applicable to a particular local FRM220 oaboap card.
1.3.6.1.4.1.4756.20.720.20.1.1ColumnoaboapChassisIndexread-onlycurrentA unique value for each local card. It is the chassis location number.
1.3.6.1.4.1.4756.20.720.20.1.2ColumnoaboapSlotIndexread-onlycurrentA unique value for each local card. It is the slot location number.
1.3.6.1.4.1.4756.20.720.20.1.3ColumnoaboapCardHWVerread-onlycurrentLocal FRM220 OABOAP card hardware version x.xxx
1.3.6.1.4.1.4756.20.720.20.1.4ColumnoaboapCardFWVerread-onlycurrentLocal FRM220 OABOAP card firmware version x.xxx
1.3.6.1.4.1.4756.20.720.20.1.5ColumnoaboapCardCPLDVerread-onlycurrentLocal FRM220 OABOAP card CPLD version x.xxx
1.3.6.1.4.1.4756.20.720.20.1.6ColumnoaboapCardFPGAVerread-onlycurrentLocal FRM220 OABOAP card FPGA version x.xxx
1.3.6.1.4.1.4756.20.720.20.1.7ColumnoaboapModelread-onlycurrentLocal CardType: 0:FRM220-OAB21 1:FRM220-OAB21A 2:FRM220-OAP10 3:FRM220-OAP17
1.3.6.1.4.1.4756.20.720.20.1.8ColumnoaboapGainread-onlycurrentLocal Frm220 OABOAP Gain (Unit is dB)
1.3.6.1.4.1.4756.20.720.20.1.9ColumnoaboapInputPowerAlarmLevelread-onlycurrentLocal Frm220 OABOAP Input Power Alarm Level (Unit is dBm)
1.3.6.1.4.1.4756.20.720.20.1.10ColumnoaboapOutputPowerAlarmLevelread-onlycurrentLocal Frm220 OABOAP Output Power Alarm Level (Unit is dBm)
1.3.6.1.4.1.4756.20.720.20.1.11ColumnoaboapOpticalInputPowerread-onlycurrentLocal Frm220 OABOAP Optical Input Power (Unit is dBm) Loss
1.3.6.1.4.1.4756.20.720.20.1.12ColumnoaboapOpticaloutputPowerread-onlycurrentLocal Frm220 OABOAP Optical Output Power (Unit is dBm) Loss
1.3.6.1.4.1.4756.20.720.20.1.13ColumnoaboapOpticalInputPowerAlarmread-onlycurrentLocal Frm220 OABOAP Optical Input Power Alarm: 0:normal 1:Abnormal
1.3.6.1.4.1.4756.20.720.20.1.14ColumnoaboapOpticaloutputPowerAlarmread-onlycurrentLocal Frm220 OABOAP Optical Input Power Alarm: 0:normal 1:Abnormal
1.3.6.1.4.1.4756.20.720.20.1.15ColumnoaboapTemperatureHighStatusread-onlycurrentLocal Frm220 OABOAP card temperature Status (Unit is degree C)
1.3.6.1.4.1.4756.20.720.20.1.16ColumnoaboapTemperatureHighAlarmread-onlycurrentLocal Frm220 OABOAP card temperature Alarm: 0:normal 1:Abnormal
1.3.6.1.4.1.4756.20.720.20.1.17ColumnoaboapLDBiasAlarmread-onlycurrentLocal Frm220 OABOAP card LD Bias Alarm: 0:normal 1:Abnormal
1.3.6.1.4.1.4756.20.720.20.1.18ColumnoaboapGainPowerread-writecurrentLocal Frm220 OABOAP card set gain power (Unit is dB)
1.3.6.1.4.1.4756.20.720.20.1.19ColumnoaboapInputPowerread-writecurrentLocal Frm220 OABOAP card set input power (Unit is dBm)
1.3.6.1.4.1.4756.20.720.20.1.20ColumnoaboapOutputPowerread-writecurrentLocal Frm220 OABOAP card set output power(Unit is dBm)
1.3.6.1.4.1.4756.20.720.20.1.21ColumnoaboapDeviceActiveread-writecurrentLocal Frm220 OABOAP card device active: 0:Disable 1:Enable
1.3.6.1.4.1.4756.20.720.20.1.22ColumnoaboapDeviceResetread-writecurrentLocal Frm220 OABOAP card device reset: 0:Off 1:Action
1.3.6.1.4.1.4756.20.720.20.1.23ColumnoaboapSetDefaultread-writecurrentLocal Frm220 OABOAP set to default: 0:Off 1:Action
1.3.6.1.4.1.4756.20.720.20.1.24ColumnoaboapTemperatureAlarmread-onlycurrentLocal Frm220 OABOAP card Temperature Alarm: 0:normal 1:Abnormal
1.3.6.1.4.1.4756.20.720.20.1.25ColumnoaboapShutdownAlarmread-onlycurrentLocal Frm220 OABOAP card Shutdown Alarm: 0:normal 1:Abnormal
1.3.6.1.4.1.4756.20.720.20.1.26ColumnoaboapDefaultAlarmread-onlycurrentLocal Frm220 OABOAP card Default SW Alarm: 0:normal 1:Abnormal
1.3.6.1.4.1.4756.20.720.20.1.27ColumnoaboapInputOverAlarmread-onlycurrentLocal Frm220 OABOAP card InputOver Alarm: 0:normal 1:Abnormal
1.3.6.1.4.1.4756.20.720.20.1.28ColumnoaboapOutputOverAlarmread-onlycurrentLocal Frm220 OABOAP card OutputOver Alarm: 0:normal 1:Abnormal
1.3.6.1.4.1.4756.20.720.20.1.29ColumnoaboapPowerLedread-onlycurrentLocal Frm220 OABOAP card Powe Led. 0:ON (Power ON) 1:Flash (Standby; 1s ON/1s OFF)
1.3.6.1.4.1.4756.20.720.20.1.30ColumnoaboapSystemLedread-onlycurrentLocal Frm220 OABOAP card Syetem Led. 0:OFF 1:ON 2:Flash
1.3.6.1.4.1.4756.20.720.20.1.31ColumnoaboapInputLedread-onlycurrentLocal Frm220 OABOAP card Input Led. 0:OFF 1:Green(Normal) 2:Red(PWR_InLow / InPWR_Fail)
1.3.6.1.4.1.4756.20.720.20.1.32ColumnoaboapOutputLedread-onlycurrentLocal Frm220 OABOAP card Output Led. 0:OFF 1:Green(Normal) 2:Red(PWR_OuLow / OuPWR_Fail)
1.3.6.1.4.1.4756.20.720.20.1.33ColumnoaboapAlarmLedread-onlycurrentLocal Frm220 OABOAP card Alarm Led. 0:OFF 1:ON
1.3.6.1.4.1.4756.20.720.20.1.34ColumnoaboapMgmtLedread-onlycurrentLocal Frm220 OABOAP card Mgmt Led. 0:OFF 1:ON
1.3.6.1.4.1.4756.20.720.20.1.35ColumnoaboapAlarmread-writecurrentLocal Frm220 OABOAP card Alarm Disable/Enable. 0:disable 1:enable
1.3.6.1.4.1.4756.20.730Nodef2000EASLocalCards
1.3.6.1.4.1.4756.20.730.20Tablef2000EASLocalTablenot-accessiblecurrentA list of Local FRM220A-2000EAS series card entries.
1.3.6.1.4.1.4756.20.730.20.1Rowf2000EASLocalEntrynot-accessiblecurrentAn entry containing management information applicable to a particular FRM220A-2000EAS series card.
1.3.6.1.4.1.4756.20.730.20.1.1Columnf2000EASChassisIndexLocalread-onlycurrentA unique value for each card. It starts from 0 to 9 contiguously.
1.3.6.1.4.1.4756.20.730.20.1.2Columnf2000EASSlotIndexLocalread-onlycurrentA unique value for each card. It starts from 1 to 20 contiguously.
1.3.6.1.4.1.4756.20.730.20.1.3Columnf2000EASCardHWVerLocalread-onlycurrentf2000EAS Series card hardware version x.xxx
1.3.6.1.4.1.4756.20.730.20.1.4Columnf2000EASCardFWVerLocalread-onlycurrentf2000EAS Series card firmware version x.xxx
1.3.6.1.4.1.4756.20.730.20.1.5Columnf2000EASCardCPLDVerLocalread-onlycurrentf2000EAS Series card CPLD version x.xxx
1.3.6.1.4.1.4756.20.730.20.1.6Columnf2000EASCardFPGAVerLocalread-onlycurrentf2000EAS Series card FPGA version x.xxx
1.3.6.1.4.1.4756.20.730.20.1.7Columnf2000EASModelLocalread-onlycurrentCard Type: 0:2000EAS/4F 1:2000EAS/2F 2:2000EAS/1F
1.3.6.1.4.1.4756.20.730.20.1.8Columnf2000EASDNSServerTypeLocalread-writecurrentf2000EAS Series card IP Configuration: This setting controls the DNS name resolution done by the switch. The following modes are supported: 0:No DNS server No …
1.3.6.1.4.1.4756.20.730.20.1.9Columnf2000EASDNSServerSettingLocalread-writecurrentf2000EAS Series card IP Configuration: If iDNSServerType setting '3:Configured',this value must setting IP address format as below: Dotted Decimal Notation ref…
1.3.6.1.4.1.4756.20.730.20.1.10Columnf2000EASDNSproxyLocalread-writecurrentf2000EAS Series card IP Configuration: When DNS proxy is enabled, system will relay DNS requests to the currently configured DNS server, and reply as a DNS res…
1.3.6.1.4.1.4756.20.730.20.1.11Columnf2000EASAddIPV4InterfaceLocalread-writecurrentf2000EAS Series card IP Interfaces: Add a new IP VLAN Interface: Syntax: [<Interface>] [<vlan_list>] [<IPV4_Addr>] [<IPV4_MASK>] Interface : 1~4
1.3.6.1.4.1.4756.20.730.20.1.12Columnf2000EASDeleteInterfaceLocalread-writecurrentf2000EAS Series card IP Interfaces: Delete a IPv4/v6 VLAN Interface: Syntax: [<Interface>] Interface: 1~4
1.3.6.1.4.1.4756.20.730.20.1.13Columnf2000EASIPInterface1VLANLocalread-onlycurrentf2000EAS Series card IP Interfaces: The VLAN associated with the IP interface. Only ports in this VLAN will be able to access the IP interface. This field is o…
1.3.6.1.4.1.4756.20.730.20.1.14Columnf2000EASIPInterface1DHCPLocalread-writecurrentf2000EAS Series card IP Interfaces: DHCP
1.3.6.1.4.1.4756.20.730.20.1.15Columnf2000EASIPInterface1FallbackLocalread-writecurrentf2000EAS Series card IP Interfaces: Fallback
1.3.6.1.4.1.4756.20.730.20.1.16Columnf2000EASIPInterface1IPV4CurrentLeaseLocalread-onlycurrentf2000EAS Series card IP Interfaces: IPV4 Current Lease Address
1.3.6.1.4.1.4756.20.730.20.1.17Columnf2000EASIPInterface1IPV4AddressLocalread-onlycurrentf2000EAS Series card IP Interfaces: IPV4 Address
1.3.6.1.4.1.4756.20.730.20.1.18Columnf2000EASIPInterface1IPV4MASKLenLocalread-onlycurrentf2000EAS Series card IP Interfaces: IPV4 MASK Length
1.3.6.1.4.1.4756.20.730.20.1.19Columnf2000EASIPInterface2VLANLocalread-onlycurrentf2000EAS Series card IP Interfaces: The VLAN associated with the IP interface. Only ports in this VLAN will be able to access the IP interface. This field is o…
1.3.6.1.4.1.4756.20.730.20.1.20Columnf2000EASIPInterface2DHCPLocalread-writecurrentf2000EASEDD Series card IP Interfaces: DHCP
1.3.6.1.4.1.4756.20.730.20.1.21Columnf2000EASIPInterface2FallbackLocalread-writecurrentf2000EASEDD Series card IP Interfaces: Fallback
1.3.6.1.4.1.4756.20.730.20.1.22Columnf2000EASIPInterface2IPV4CurrentLeaseLocalread-onlycurrentf2000EAS Series card IP Interfaces: IPV4 Current Lease Address
1.3.6.1.4.1.4756.20.730.20.1.23Columnf2000EASIPInterface2IPV4AddressLocalread-onlycurrentf2000EAS Series card IP Interfaces: IPV4 Address
1.3.6.1.4.1.4756.20.730.20.1.24Columnf2000EASIPInterface2IPV4MASKLenLocalread-onlycurrentf2000EAS Series card IP Interfaces: IPV4 MASK Length
1.3.6.1.4.1.4756.20.730.20.1.25Columnf2000EASIPInterface3VLANLocalread-onlycurrentf2000EAS Series card IP Interfaces: The VLAN associated with the IP interface. Only ports in this VLAN will be able to access the IP interface. This field is o…
1.3.6.1.4.1.4756.20.730.20.1.26Columnf2000EASIPInterface3DHCPLocalread-writecurrentf2000EAS Series card IP Interfaces: DHCP
1.3.6.1.4.1.4756.20.730.20.1.27Columnf2000EASIPInterface3FallbackLocalread-writecurrentf2000EAS Series card IP Interfaces: Fallback
1.3.6.1.4.1.4756.20.730.20.1.28Columnf2000EASIPInterface3IPV4CurrentLeaseLocalread-onlycurrentf2000EAS Series card IP Interfaces: IPV4 Current Lease Address
1.3.6.1.4.1.4756.20.730.20.1.29Columnf2000EASIPInterface3IPV4AddressLocalread-onlycurrentf2000EAS Series card IP Interfaces: IPV4 Address
1.3.6.1.4.1.4756.20.730.20.1.30Columnf2000EASIPInterface3IPV4MASKLenLocalread-onlycurrentf2000EAS Series card IP Interfaces: IPV4 MASK Length
1.3.6.1.4.1.4756.20.730.20.1.31Columnf2000EASIPInterface4VLANLocalread-onlycurrentf2000EAS Series card IP Interfaces: The VLAN associated with the IP interface. Only ports in this VLAN will be able to access the IP interface. This field is o…
1.3.6.1.4.1.4756.20.730.20.1.32Columnf2000EASIPInterface4DHCPLocalread-writecurrentf2000EAS Series card IP Interfaces: DHCP
1.3.6.1.4.1.4756.20.730.20.1.33Columnf2000EASIPInterface4FallbackLocalread-writecurrentf2000EAS Series card IP Interfaces: Fallback
1.3.6.1.4.1.4756.20.730.20.1.34Columnf2000EASIPInterface4IPV4CurrentLeaseLocalread-onlycurrentf2000EAS Series card IP Interfaces: IPV4 Current Lease Address
1.3.6.1.4.1.4756.20.730.20.1.35Columnf2000EASIPInterface4IPV4AddressLocalread-onlycurrentf2000EAS Series card IP Interfaces: IPV4 Address
1.3.6.1.4.1.4756.20.730.20.1.36Columnf2000EASIPInterface4IPV4MASKLenLocalread-onlycurrentf2000EAS Series card IP Interfaces: IPV4 MASK Length
1.3.6.1.4.1.4756.20.730.20.1.37Columnf2000EASAddIPV6InterfaceLocalread-writecurrentf2000EAS Series card IP Interfaces: Add a new IPv6 VLAN Interface: Syntax: [<Interface>] [<vlan_list>] [<IPV4_Addr>] [<IPV4_MASK>] Interface : 1~4
1.3.6.1.4.1.4756.20.730.20.1.38Columnf2000EASIPInterface1IPV6DHCPLocalread-writecurrentf2000EAS Series card IP Interfaces: IPV6 DHCP
1.3.6.1.4.1.4756.20.730.20.1.39Columnf2000EASIPInterface1IPV6RapidCommitLocalread-writecurrentf2000EAS Series card IP Interfaces1: IPV6 RapidCommit
1.3.6.1.4.1.4756.20.730.20.1.40Columnf2000EASIPInterface1IPV6CurrentLeaseLocalread-onlycurrentf2000EAS Series card IP Interfaces: IPV6 Current lease Address
1.3.6.1.4.1.4756.20.730.20.1.41Columnf2000EASIPInterface1IPV6AddressLocalread-onlycurrentf2000EAS Series card IP Interfaces: IPV6 Address
1.3.6.1.4.1.4756.20.730.20.1.42Columnf2000EASIPInterface1IPV6MASKLenLocalread-onlycurrentf2000EAS Series card IP Interfaces: IPV6 MASK Length
1.3.6.1.4.1.4756.20.730.20.1.43Columnf2000EASIPInterface2IPV6DHCPLocalread-writecurrentf2000EAS Series card IP Interfaces2: IPV6 DHCP
1.3.6.1.4.1.4756.20.730.20.1.44Columnf2000EASIPInterface2IPV6RapidCommitLocalread-writecurrentf2000EAS Series card IP Interfaces2: IPV6 RapidCommit
1.3.6.1.4.1.4756.20.730.20.1.45Columnf2000EASIPInterface2IPV6CurrentLeaseLocalread-onlycurrentf2000EAS Series card IP Interfaces: IPV6 Current lease Address
1.3.6.1.4.1.4756.20.730.20.1.46Columnf2000EASIPInterface2IPV6AddressLocalread-onlycurrentf2000EAS Series card IP Interfaces: IPV6 Address
1.3.6.1.4.1.4756.20.730.20.1.47Columnf2000EASIPInterface2IPV6MASKLenLocalread-onlycurrentf2000EAS Series card IP Interfaces: IPV6 MASK Length
1.3.6.1.4.1.4756.20.730.20.1.48Columnf2000EASIPInterface3IPV6DHCPLocalread-writecurrentf2000EAS Series card IP Interfaces2: IPV6 DHCP
1.3.6.1.4.1.4756.20.730.20.1.49Columnf2000EASIPInterface3IPV6RapidCommitLocalread-writecurrentf2000EAS Series card IP Interfaces3: IPV6 RapidCommit
1.3.6.1.4.1.4756.20.730.20.1.50Columnf2000EASIPInterface3IPV6CurrentLeaseLocalread-onlycurrentf2000EAS Series card IP Interfaces: IPV6 Current lease Address
1.3.6.1.4.1.4756.20.730.20.1.51Columnf2000EASIPInterface3IPV6AddressLocalread-onlycurrentf2000EAS Series card IP Interfaces3: IPV6 Address
1.3.6.1.4.1.4756.20.730.20.1.52Columnf2000EASIPInterface3IPV6MASKLenLocalread-onlycurrentf2000EAS Series card IP Interfaces: IPV6 MASK Length
1.3.6.1.4.1.4756.20.730.20.1.53Columnf2000EASIPInterface4IPV6DHCPLocalread-writecurrentf2000EAS Series card IP Interfaces4: IPV6 DHCP
1.3.6.1.4.1.4756.20.730.20.1.54Columnf2000EASIPInterface4IPV6RapidCommitLocalread-writecurrentf2000EAS Series card IP Interfaces4: IPV6 RapidCommit
1.3.6.1.4.1.4756.20.730.20.1.55Columnf2000EASIPInterface4IPV6CurrentLeaseLocalread-onlycurrentf2000EAS Series card IP Interfaces: IPV6 Current lease Address
1.3.6.1.4.1.4756.20.730.20.1.56Columnf2000EASIPInterface4IPV6AddressLocalread-onlycurrentf2000EAS Series card IP Interfaces: IPV6 Address
1.3.6.1.4.1.4756.20.730.20.1.57Columnf2000EASIPInterface4IPV6MASKLenLocalread-onlycurrentf2000EAS Series card IP Interfaces: IPV6 MASK Length
1.3.6.1.4.1.4756.20.730.20.1.58Columnf2000EASIPRoutes1NetworkLocalread-onlycurrentf2000EAS Series card IP Routes: NetWork
1.3.6.1.4.1.4756.20.730.20.1.59Columnf2000EASIPRoutes1MASKLenLocalread-onlycurrentf2000EAS Series card IP Routes: MASK Length
1.3.6.1.4.1.4756.20.730.20.1.60Columnf2000EASIPRoutes1GetwayLocalread-onlycurrentf2000EAS Series card IP Routes: Getway
1.3.6.1.4.1.4756.20.730.20.1.61Columnf2000EASIPRoutes1HopVLANLocalread-onlycurrentf2000EAS Series card IP Routes: The VLAN associated with the IP Routes. Only ports in this VLAN will be able to access the IP Routes.
1.3.6.1.4.1.4756.20.730.20.1.62Columnf2000EASIPRoutes2NetworkLocalread-onlycurrentf2000EAS Series card IP Routes: NetWork
1.3.6.1.4.1.4756.20.730.20.1.63Columnf2000EASIPRoutes2MASKLenLocalread-onlycurrentf2000EAS Series card IP Routes: MASK Length
1.3.6.1.4.1.4756.20.730.20.1.64Columnf2000EASIPRoutes2GetwayLocalread-onlycurrentf2000EAS Series card IP Routes: Getway
1.3.6.1.4.1.4756.20.730.20.1.65Columnf2000EASIPRoutes2HopVLANLocalread-onlycurrentf2000EAS Series card IP Routes: The VLAN associated with the IP Routes. Only ports in this VLAN will be able to access the IP Routes.
1.3.6.1.4.1.4756.20.730.20.1.66Columnf2000EASIPRoutes3NetworkLocalread-onlycurrentf2000EAS Series card IP Routes: NetWork
1.3.6.1.4.1.4756.20.730.20.1.67Columnf2000EASIPRoutes3MASKLenLocalread-onlycurrentf2000EAS Series card IP Routes: MASK Length
1.3.6.1.4.1.4756.20.730.20.1.68Columnf2000EASIPRoutes3GetwayLocalread-onlycurrentf2000EAS Series card IP Routes: Getway
1.3.6.1.4.1.4756.20.730.20.1.69Columnf2000EASIPRoutes3HopVLANLocalread-onlycurrentf2000EAS Series card IP Routes: The VLAN associated with the IP Routes. Only ports in this VLAN will be able to access the IP Routes.
1.3.6.1.4.1.4756.20.730.20.1.70Columnf2000EASIPRoutes4NetworkLocalread-onlycurrentf2000EAS Series card IP Routes: NetWork
1.3.6.1.4.1.4756.20.730.20.1.71Columnf2000EASIPRoutes4MASKLenLocalread-onlycurrentf2000EAS Series card IP Routes: MASK Length
1.3.6.1.4.1.4756.20.730.20.1.72Columnf2000EASIPRoutes4GetwayLocalread-onlycurrentf2000EAS Series card IP Routes: Getway
1.3.6.1.4.1.4756.20.730.20.1.73Columnf2000EASIPRoutes4HopVLANLocalread-onlycurrentf2000EAS Series card IP Routes: The VLAN associated with the IP Routes. Only ports in this VLAN will be able to access the IP Routes.
1.3.6.1.4.1.4756.20.730.20.1.74Columnf2000EASPort1LinkstsLocalread-onlycurrentf2000EAS Series card Port1 link status: 0:Link down 1:Link up
1.3.6.1.4.1.4756.20.730.20.1.75Columnf2000EASPort1SpeedstsLocalread-onlycurrentf2000EAS Series card Port1 speed status
1.3.6.1.4.1.4756.20.730.20.1.76Columnf2000EASPort1DuplexstsLocalread-onlycurrentf2000EAS Series card Port1 duplex status 0: Half 1: Full
1.3.6.1.4.1.4756.20.730.20.1.77Columnf2000EASPort1RxPausestsLocalread-onlycurrentf2000EAS Series card Port1 rx pause status 0: No 1: Yes
1.3.6.1.4.1.4756.20.730.20.1.78Columnf2000EASPort1TxPausestsLocalread-onlycurrentf2000EAS Series card Port1 tx pause status 0: No 1: Yes
1.3.6.1.4.1.4756.20.730.20.1.79Columnf2000EASPort2LinkstsLocalread-onlycurrentf2000EAS Series card Port2 link status: 0:Link down 1:Link up
1.3.6.1.4.1.4756.20.730.20.1.80Columnf2000EASPort2SpeedstsLocalread-onlycurrentf2000EAS Series card Port2 speed status
1.3.6.1.4.1.4756.20.730.20.1.81Columnf2000EASPort2DuplexstsLocalread-onlycurrentf2000EAS Series card Port2 duplex status 0: Half 1: Full
1.3.6.1.4.1.4756.20.730.20.1.82Columnf2000EASPort2RxPausestsLocalread-onlycurrentf2000EAS Series card Port2 rx pause status 0: No 1: Yes
1.3.6.1.4.1.4756.20.730.20.1.83Columnf2000EASPort2TxPausestsLocalread-onlycurrentf2000EAS Series card Port2 tx pause status 0: No 1: Yes
1.3.6.1.4.1.4756.20.730.20.1.84Columnf2000EASPort3LinkstsLocalread-onlycurrentf2000EAS Series card Port3 link status: 0:Link down 1:Link up
1.3.6.1.4.1.4756.20.730.20.1.85Columnf2000EASPort3SpeedstsLocalread-onlycurrentf2000EAS Series card Port3 speed status
1.3.6.1.4.1.4756.20.730.20.1.86Columnf2000EASPort3DuplexstsLocalread-onlycurrentf2000EAS Series card Port3 duplex status 0: Half 1: Full
1.3.6.1.4.1.4756.20.730.20.1.87Columnf2000EASPort3RxPausestsLocalread-onlycurrentf2000EAS Series card Port3 rx pause status 0: No 1: Yes
1.3.6.1.4.1.4756.20.730.20.1.88Columnf2000EASPort3TxPausestsLocalread-onlycurrentf2000EAS Series card Port3 tx pause status 0: No 1: Yes
1.3.6.1.4.1.4756.20.730.20.1.89Columnf2000EASPort4LinkstsLocalread-onlycurrentf2000EAS Series card Port4 link status: 0:Link down 1:Link up
1.3.6.1.4.1.4756.20.730.20.1.90Columnf2000EASPort4SpeedstsLocalread-onlycurrentf2000EAS Series card Port4 speed status
1.3.6.1.4.1.4756.20.730.20.1.91Columnf2000EASPort4DuplexstsLocalread-onlycurrentf2000EAS Series card Port4 duplex status 0: Half 1: Full
1.3.6.1.4.1.4756.20.730.20.1.92Columnf2000EASPort4RxPausestsLocalread-onlycurrentf2000EAS Series card Port4 rx pause status 0: No 1: Yes
1.3.6.1.4.1.4756.20.730.20.1.93Columnf2000EASPort4TxPausestsLocalread-onlycurrentf2000EAS Series card Port4 tx pause status 0: No 1: Yes
1.3.6.1.4.1.4756.20.730.20.1.94Columnf2000EASPort1SpeedConfLocalread-writecurrentf2000EAS Series card Port1 speed config 0: disable 1: auto 2: 100M FDX 3: 1G FDX
1.3.6.1.4.1.4756.20.730.20.1.95Columnf2000EASPort1flowConrolLocalread-writecurrentf2000EAS Series card Port1 flow control config 0: no 1: yes
1.3.6.1.4.1.4756.20.730.20.1.96Columnf2000EASPort1MaxFrameLocalread-writecurrentf2000EAS Series card Port1 max frame config
1.3.6.1.4.1.4756.20.730.20.1.97Columnf2000EASPort1ALSLocalread-writecurrentf2000EAS Series card Port1 auto laser shutdown: 0: Disable 1: Enable
1.3.6.1.4.1.4756.20.730.20.1.98Columnf2000EASPort1FrameLengthCheckLocalread-writecurrentf2000EAS Series card Port1 Frame Length Check config 0: no 1: yes
1.3.6.1.4.1.4756.20.730.20.1.99Columnf2000EASPort2SpeedConfLocalread-writecurrentf2000EAS Series card Port2 speed config 0: disable 1: auto 2: 100M FDX 3: 1G FDX
1.3.6.1.4.1.4756.20.730.20.1.100Columnf2000EASPort2flowConrolLocalread-writecurrentf2000EAS Series card Port2 flow control config 0: no 1: yes
1.3.6.1.4.1.4756.20.730.20.1.101Columnf2000EASPort2MaxFrameLocalread-writecurrentf2000EAS Series card Port2 max frame config
1.3.6.1.4.1.4756.20.730.20.1.102Columnf2000EASPort2ALSLocalread-writecurrentf2000EAS Series card Port2 auto laser shutdown: 0: Disable 1: Enable
1.3.6.1.4.1.4756.20.730.20.1.103Columnf2000EASPort2FrameLengthCheckLocalread-writecurrentf2000EAS Series card Port2 Frame Length Check config 0: no 1: yes
1.3.6.1.4.1.4756.20.730.20.1.104Columnf2000EASPort3SpeedConfLocalread-writecurrentf2000EAS Series card Port3 speed config 0: disable 1: auto 2: 10M HDX 3: 10M FDX 4: 100M HDX 5: 100M FDX 6: 1G FDX
1.3.6.1.4.1.4756.20.730.20.1.105Columnf2000EASPort3flowConrolLocalread-writecurrentf2000EAS Series card Port3 flow control config 0: no 1: yes
1.3.6.1.4.1.4756.20.730.20.1.106Columnf2000EASPort3MaxFrameLocalread-writecurrentf2000EAS Series card Port3 max frame config
1.3.6.1.4.1.4756.20.730.20.1.107Columnf2000EASPort3CollisionModeLocalread-writecurrentf2000EAS Series card Port3 collision mode config. 0: Discard 1: Restart
1.3.6.1.4.1.4756.20.730.20.1.108Columnf2000EASPort3ALSLocalread-writecurrentf2000EAS Series card Port3 auto laser shutdown 0: Disable 1: Enable
1.3.6.1.4.1.4756.20.730.20.1.109Columnf2000EASPort3FrameLengthCheckLocalread-writecurrentf2000EAS Series card Port3 Frame Length Check config 0: no 1: yes
1.3.6.1.4.1.4756.20.730.20.1.110Columnf2000EASPort4SpeedConfLocalread-writecurrentf2000EAS Series card Port4 speed config 0: disable 1: auto 2: 10M HDX 3: 10M FDX 4: 100M HDX 5: 100M FDX 6: 1G FDX
1.3.6.1.4.1.4756.20.730.20.1.111Columnf2000EASPort4flowConrolLocalread-writecurrentf2000EAS Series card Port4 flow control config 0: no 1: yes
1.3.6.1.4.1.4756.20.730.20.1.112Columnf2000EASPort4MaxFrameLocalread-writecurrentf2000EAS Series card Port4 max frame config
1.3.6.1.4.1.4756.20.730.20.1.113Columnf2000EASPort4CollisionModeLocalread-writecurrentf2000EAS Series card Port4 collision mode config 0: Discard 1: Restart
1.3.6.1.4.1.4756.20.730.20.1.114Columnf2000EASPort4ALSLocalread-writecurrentf2000EAS Series card Port4 auto laser shutdown 0: Disable 1: Enable
1.3.6.1.4.1.4756.20.730.20.1.115Columnf2000EASPort4FrameLengthCheckLocalread-writecurrentf2000EAS Series card Port4 Frame Length Check config 0: no 1: yes
1.3.6.1.4.1.4756.20.730.20.1.116Columnf2000EASPort1AdvDuplexHdxLocalread-writecurrentf2000EAS Series card Port1 Adv Dpulex Hdx 0: OFF 1: ON
1.3.6.1.4.1.4756.20.730.20.1.117Columnf2000EASPort1AdvDuplexFdxLocalread-writecurrentf2000EAS Series card Port1 Adv Dpulex Fdx 0: OFF 1: ON
1.3.6.1.4.1.4756.20.730.20.1.118Columnf2000EASPort1AdvSpeed10MLocalread-writecurrentf2000EAS Series card Port1 Adv Speed 10M 0: OFF 1: ON
1.3.6.1.4.1.4756.20.730.20.1.119Columnf2000EASPort1AdvSpeed100MLocalread-writecurrentf2000EAS Series card Port1 Adv Speed 100M 0: OFF 1: ON
1.3.6.1.4.1.4756.20.730.20.1.120Columnf2000EASPort1AdvSpeed1GLocalread-writecurrentf2000EAS Series card Port1 Adv Speed 1G 0: OFF 1: ON
1.3.6.1.4.1.4756.20.730.20.1.121Columnf2000EASPort2AdvDuplexHdxLocalread-writecurrentf2000EAS Series card Port2 Adv Dpulex Hdx 0: OFF 1: ON
1.3.6.1.4.1.4756.20.730.20.1.122Columnf2000EASPort2AdvDuplexFdxLocalread-writecurrentf2000EAS Series card Port2 Adv Dpulex Fdx 0: OFF 1: ON
1.3.6.1.4.1.4756.20.730.20.1.123Columnf2000EASPort2AdvSpeed10MLocalread-writecurrentf2000EAS Series card Port2 Adv Speed 10M 0: OFF 1: ON
1.3.6.1.4.1.4756.20.730.20.1.124Columnf2000EASPort2AdvSpeed100MLocalread-writecurrentf2000EAS Series card Port2 Adv Speed 100M 0: OFF 1: ON
1.3.6.1.4.1.4756.20.730.20.1.125Columnf2000EASPort2AdvSpeed1GLocalread-writecurrentf2000EAS Series card Port2 Adv Speed 1G 0: OFF 1: ON
1.3.6.1.4.1.4756.20.730.20.1.126Columnf2000EASPort3AdvDuplexHdxLocalread-writecurrentf2000EAS Series card Port3 Adv Dpulex Hdx 0: OFF 1: ON
1.3.6.1.4.1.4756.20.730.20.1.127Columnf2000EASPort3AdvDuplexFdxLocalread-writecurrentf2000EAS Series card Port3 Adv Dpulex Fdx 0: OFF 1: ON
1.3.6.1.4.1.4756.20.730.20.1.128Columnf2000EASPort3AdvSpeed10MLocalread-writecurrentf2000EAS Series card Port3 Adv Speed 10M 0: OFF 1: ON
1.3.6.1.4.1.4756.20.730.20.1.129Columnf2000EASPort3AdvSpeed100MLocalread-writecurrentf2000EAS Series card Port3 Adv Speed 100M 0: OFF 1: ON
1.3.6.1.4.1.4756.20.730.20.1.130Columnf2000EASPort3AdvSpeed1GLocalread-writecurrentf2000EAS Series card Port3 Adv Speed 1G 0: OFF 1: ON
1.3.6.1.4.1.4756.20.730.20.1.131Columnf2000EASPort4AdvDuplexHdxLocalread-writecurrentf2000EAS Series card Port4 Adv Dpulex Hdx 0: OFF 1: ON
1.3.6.1.4.1.4756.20.730.20.1.132Columnf2000EASPort4AdvDuplexFdxLocalread-writecurrentf2000EAS Series card Port4 Adv Dpulex Fdx 0: OFF 1: ON
1.3.6.1.4.1.4756.20.730.20.1.133Columnf2000EASPort4AdvSpeed10MLocalread-writecurrentf2000EAS Series card Port4 Adv Speed 10M 0: OFF 1: ON
1.3.6.1.4.1.4756.20.730.20.1.134Columnf2000EASPort4AdvSpeed100MLocalread-writecurrentf2000EAS Series card Port4 Adv Speed 100M 0: OFF 1: ON
1.3.6.1.4.1.4756.20.730.20.1.135Columnf2000EASPort4AdvSpeed1GLocalread-writecurrentf2000EAS Series card Port4 Adv Speed 1G 0: OFF 1: ON
1.3.6.1.4.1.4756.20.730.20.1.136Columnf2000EASPortResetLocalread-writecurrentf2000EAS Series card port reset 0: OFF 1: Action
1.3.6.1.4.1.4756.20.730.20.1.137Columnf2000EASSetDefaultLocalread-writecurrentf2000EAS Series card set to default config 0: OFF 1: Action
1.3.6.1.4.1.4756.20.730.20.1.138Columnf2000EASPort1PacketsRxLocalread-onlycurrentf2000EAS Series card port1 traffic overview:: Packets Rx
1.3.6.1.4.1.4756.20.730.20.1.139Columnf2000EASPort1PacketsTxLocalread-onlycurrentf2000EAS Series card port1 traffic overview:: Packets Tx
1.3.6.1.4.1.4756.20.730.20.1.140Columnf2000EASPort1BytesRxLocalread-onlycurrentf2000EAS Series card port1 traffic overview:: Bytes Rx
1.3.6.1.4.1.4756.20.730.20.1.141Columnf2000EASPort1BytesTxLocalread-onlycurrentf2000EAS Series card port1 traffic overview:: Bytes Tx
1.3.6.1.4.1.4756.20.730.20.1.142Columnf2000EASPort1ErrorsRxLocalread-onlycurrentf2000EAS Series card port1 traffic overview:: Errors Rx
1.3.6.1.4.1.4756.20.730.20.1.143Columnf2000EASPort1ErrorsTxLocalread-onlycurrentf2000EAS Series card port1 traffic overview:: Errors Tx
1.3.6.1.4.1.4756.20.730.20.1.144Columnf2000EASPort1DropsRxLocalread-onlycurrentf2000EAS Series card port1 traffic overview:: Drops Rx
1.3.6.1.4.1.4756.20.730.20.1.145Columnf2000EASPort1DropsTxLocalread-onlycurrentf2000EAS Series card port1 traffic overview:: Drops Tx
1.3.6.1.4.1.4756.20.730.20.1.146Columnf2000EASPort1FilteredRxLocalread-onlycurrentf2000EAS Series card port1 traffic overview:: Filtered Rx
1.3.6.1.4.1.4756.20.730.20.1.147Columnf2000EASPort2PacketsRxLocalread-onlycurrentf2000EAS Series card port2 traffic overview:: Packets Rx
1.3.6.1.4.1.4756.20.730.20.1.148Columnf2000EASPort2PacketsTxLocalread-onlycurrentf2000EAS Series card port2 traffic overview:: Packets Tx
1.3.6.1.4.1.4756.20.730.20.1.149Columnf2000EASPort2BytesRxLocalread-onlycurrentf2000EAS Series card port2 traffic overview:: Bytes Rx
1.3.6.1.4.1.4756.20.730.20.1.150Columnf2000EASPort2BytesTxLocalread-onlycurrentf2000EAS Series card port2 traffic overview:: Bytes Tx
1.3.6.1.4.1.4756.20.730.20.1.151Columnf2000EASPort2ErrorsRxLocalread-onlycurrentf2000EAS Series card port2 traffic overview:: Errors Rx
1.3.6.1.4.1.4756.20.730.20.1.152Columnf2000EASPort2ErrorsTxLocalread-onlycurrentf2000EAS Series card port2 traffic overview:: Errors Tx
1.3.6.1.4.1.4756.20.730.20.1.153Columnf2000EASPort2DropsRxLocalread-onlycurrentf2000EAS Series card port2 traffic overview:: Drops Rx
1.3.6.1.4.1.4756.20.730.20.1.154Columnf2000EASPort2DropsTxLocalread-onlycurrentf2000EAS Series card port2 traffic overview:: Drops Tx
1.3.6.1.4.1.4756.20.730.20.1.155Columnf2000EASPort2FilteredRxLocalread-onlycurrentf2000EAS Series card port2 traffic overview:: Filtered Rx
1.3.6.1.4.1.4756.20.730.20.1.156Columnf2000EASPort3PacketsRxLocalread-onlycurrentf2000EAS Series card port3 traffic overview:: Packets Rx
1.3.6.1.4.1.4756.20.730.20.1.157Columnf2000EASPort3PacketsTxLocalread-onlycurrentf2000EAS Series card port3 traffic overview:: Packets Tx
1.3.6.1.4.1.4756.20.730.20.1.158Columnf2000EASPort3BytesRxLocalread-onlycurrentf2000EAS Series card port3 traffic overview:: Bytes Rx
1.3.6.1.4.1.4756.20.730.20.1.159Columnf2000EASPort3BytesTxLocalread-onlycurrentf2000EAS Series card port3 traffic overview:: Bytes Tx
1.3.6.1.4.1.4756.20.730.20.1.160Columnf2000EASPort3ErrorsRxLocalread-onlycurrentf2000EAS Series card port3 traffic overview:: Errors Rx
1.3.6.1.4.1.4756.20.730.20.1.161Columnf2000EASPort3ErrorsTxLocalread-onlycurrentf2000EAS Series card port3 traffic overview:: Errors Tx
1.3.6.1.4.1.4756.20.730.20.1.162Columnf2000EASPort3DropsRxLocalread-onlycurrentf2000EAS Series card port3 traffic overview:: Drops Rx
1.3.6.1.4.1.4756.20.730.20.1.163Columnf2000EASPort3DropsTxLocalread-onlycurrentf2000EAS Series card port3 traffic overview:: Drops Tx
1.3.6.1.4.1.4756.20.730.20.1.164Columnf2000EASPort3FilteredRxLocalread-onlycurrentf2000EAS Series card port3 traffic overview:: Filtered Rx
1.3.6.1.4.1.4756.20.730.20.1.165Columnf2000EASPort4PacketsRxLocalread-onlycurrentf2000EAS Series card port4 traffic overview:: Packets Rx
1.3.6.1.4.1.4756.20.730.20.1.166Columnf2000EASPort4PacketsTxLocalread-onlycurrentf2000EAS Series card port4 traffic overview:: Packets Tx
1.3.6.1.4.1.4756.20.730.20.1.167Columnf2000EASPort4BytesRxLocalread-onlycurrentf2000EAS Series card port4 traffic overview:: Bytes Rx
1.3.6.1.4.1.4756.20.730.20.1.168Columnf2000EASPort4BytesTxLocalread-onlycurrentf2000EAS Series card port4 traffic overview:: Bytes Tx
1.3.6.1.4.1.4756.20.730.20.1.169Columnf2000EASPort4ErrorsRxLocalread-onlycurrentf2000EAS Series card port4 traffic overview:: Errors Rx
1.3.6.1.4.1.4756.20.730.20.1.170Columnf2000EASPort4ErrorsTxLocalread-onlycurrentf2000EAS Series card port4 traffic overview:: Errors Tx
1.3.6.1.4.1.4756.20.730.20.1.171Columnf2000EASPort4DropsRxLocalread-onlycurrentf2000EAS Series card port4 traffic overview:: Drops Rx
1.3.6.1.4.1.4756.20.730.20.1.172Columnf2000EASPort4DropsTxLocalread-onlycurrentf2000EAS Series card port4 traffic overview:: Drops Tx
1.3.6.1.4.1.4756.20.730.20.1.173Columnf2000EASPort4FilteredRxLocalread-onlycurrentf2000EAS Series card port4 traffic overview:: Filtered Rx
1.3.6.1.4.1.4756.20.730.20.1.174Columnf2000EASDeviceActiveLocalread-onlycurrentf2000EAS Series card device active 0: Disable 1: Enable
1.3.6.1.4.1.4756.20.730.20.1.175Columnf2000EASFx1DDLocalread-onlycurrentf2000EAS Series card fiber1 port Digital Diagnostic function: 0:No 1:Yes
1.3.6.1.4.1.4756.20.730.20.1.176Columnf2000EASFx1DDVendorLocalread-onlycurrentf2000EAS Series card fiber1 port D/D information: Vendor name
1.3.6.1.4.1.4756.20.730.20.1.177Columnf2000EASFx1DDPartNoLocalread-onlycurrentf2000EAS Series card fiber1 port D/D information: Vendor part number
1.3.6.1.4.1.4756.20.730.20.1.178Columnf2000EASFx1DDFiberTypeLocalread-onlycurrentf2000EAS Series card fiber1 port D/D information: Fiber Type
1.3.6.1.4.1.4756.20.730.20.1.179Columnf2000EASFx1DDWaveLenLocalread-onlycurrentf2000EAS Series card fiber1 port D/D information: Wave length
1.3.6.1.4.1.4756.20.730.20.1.180Columnf2000EASFx1DDWaveLen2Localread-onlycurrentf2000EAS Series card fiber1 port D/D information: Wave length 2
1.3.6.1.4.1.4756.20.730.20.1.181Columnf2000EASFx1DDLinkLenLocalread-onlycurrentf2000EAS Series card fiber1 port D/D information: Link length
1.3.6.1.4.1.4756.20.730.20.1.182Columnf2000EASFx1DDLenUnitLocalread-onlycurrentf2000EAS Series card fiber1 port D/D information: Length Unit
1.3.6.1.4.1.4756.20.730.20.1.183Columnf2000EASFx1DDStatusLocalread-onlycurrentf2000EAS Series card fiber1 port D/D information: Status Support
1.3.6.1.4.1.4756.20.730.20.1.184Columnf2000EASFx1DDRxSensLocalread-onlycurrentf2000EAS Series card fiber1 port D/D information: Rx Sensitivity
1.3.6.1.4.1.4756.20.730.20.1.185Columnf2000EASFx1DDTxPWRLocalread-onlycurrentf2000EAS Series card fiber1 port D/D information: Tx power
1.3.6.1.4.1.4756.20.730.20.1.186Columnf2000EASFx1DDRxPWRLocalread-onlycurrentf2000EAS Series card fiber1 port D/D information: Rx power
1.3.6.1.4.1.4756.20.730.20.1.187Columnf2000EASFx1DDTempLocalread-onlycurrentf2000EAS Series card fiber1 port D/D information: Temperature in degree C
1.3.6.1.4.1.4756.20.730.20.1.188Columnf2000EASFx1DDPWRMarginLocalread-onlycurrentf2000EAS Series card fiber1 port D/D information: Power margin
1.3.6.1.4.1.4756.20.730.20.1.189Columnf2000EASFx1DDPWRLossLocalread-onlycurrentf2000EAS Series card fiber1 port D/D information: Power loss
1.3.6.1.4.1.4756.20.730.20.1.190Columnf2000EASFx2DDLocalread-onlycurrentf2000EAS Series card fiber2 Digital Diagnostic function: 0:NO 1:Yes
1.3.6.1.4.1.4756.20.730.20.1.191Columnf2000EASFx2DDVendorLocalread-onlycurrentf2000EAS Series card fiber2 D/D information: Vendor name
1.3.6.1.4.1.4756.20.730.20.1.192Columnf2000EASFx2DDPartNoLocalread-onlycurrentf2000EAS Series card fiber2 D/D information: Vendor part number
1.3.6.1.4.1.4756.20.730.20.1.193Columnf2000EASFx2DDFiberTypeLocalread-onlycurrentf2000EAS Series card fiber2 D/D information: Fiber Type
1.3.6.1.4.1.4756.20.730.20.1.194Columnf2000EASFx2DDWaveLenLocalread-onlycurrentf2000EAS Series card fiber2 D/D information: Wave length 1
1.3.6.1.4.1.4756.20.730.20.1.195Columnf2000EASFx2DDWaveLen2Localread-onlycurrentf2000EAS Series card fiber2 D/D information: Wave length 2
1.3.6.1.4.1.4756.20.730.20.1.196Columnf2000EASFx2DDLinkLenLocalread-onlycurrentf2000EAS Series card fiber2 D/D information: Link length
1.3.6.1.4.1.4756.20.730.20.1.197Columnf2000EASFx2DDLenUnitLocalread-onlycurrentf2000EAS Series card fiber2 D/D information: Length Unit
1.3.6.1.4.1.4756.20.730.20.1.198Columnf2000EASFx2DDStatusLocalread-onlycurrentf2000EAS Series card fiber2 D/D information: Status Support
1.3.6.1.4.1.4756.20.730.20.1.199Columnf2000EASFx2DDRxSensLocalread-onlycurrentf2000EAS Series card fiber2 D/D information: Rx Sensitivity
1.3.6.1.4.1.4756.20.730.20.1.200Columnf2000EASFx2DDTxPWRLocalread-onlycurrentf2000EAS Series card fiber2 D/D information: Tx power
1.3.6.1.4.1.4756.20.730.20.1.201Columnf2000EASFx2DDRxPWRLocalread-onlycurrentf2000EAS Series card fiber2 D/D information: Rx power
1.3.6.1.4.1.4756.20.730.20.1.202Columnf2000EASFx2DDTempLocalread-onlycurrentf2000EAS Series card fiber2 D/D information: Temperature in degree C
1.3.6.1.4.1.4756.20.730.20.1.203Columnf2000EASFx2DDPWRMarginLocalread-onlycurrentf2000EAS Series card fiber2 D/D information: Power margin
1.3.6.1.4.1.4756.20.730.20.1.204Columnf2000EASFx2DDPWRLossLocalread-onlycurrentf2000EAS Series card fiber2 D/D information: Power loss
1.3.6.1.4.1.4756.20.730.20.1.205Columnf2000EASFx3DDLocalread-onlycurrentf2000EAS Series card fiber3 Digital Diagnostic function: 0:NO 1:Yes
1.3.6.1.4.1.4756.20.730.20.1.206Columnf2000EASFx3DDVendorLocalread-onlycurrentf2000EAS Series card fiber3 D/D information: Vendor name
1.3.6.1.4.1.4756.20.730.20.1.207Columnf2000EASFx3DDPartNoLocalread-onlycurrentf2000EAS Series card fiber32 D/D information: Vendor part number
1.3.6.1.4.1.4756.20.730.20.1.208Columnf2000EASFx3DDFiberTypeLocalread-onlycurrentf2000EAS Series card fiber3 D/D information: Fiber Type
1.3.6.1.4.1.4756.20.730.20.1.209Columnf2000EASFx3DDWaveLenLocalread-onlycurrentf2000EAS Series card fiber3 D/D information: Wave length 1
1.3.6.1.4.1.4756.20.730.20.1.210Columnf2000EASFx3DDWaveLen2Localread-onlycurrentf2000EAS Series card fiber3 D/D information: Wave length 2
1.3.6.1.4.1.4756.20.730.20.1.211Columnf2000EASFx3DDLinkLenLocalread-onlycurrentf2000EAS Series card fiber3 D/D information: Link length
1.3.6.1.4.1.4756.20.730.20.1.212Columnf2000EASFx3DDLenUnitLocalread-onlycurrentf2000EAS Series card fiber3 D/D information: Length Unit
1.3.6.1.4.1.4756.20.730.20.1.213Columnf2000EASFx3DDStatusLocalread-onlycurrentf2000EAS Series card fiber3 D/D information: Status Support
1.3.6.1.4.1.4756.20.730.20.1.214Columnf2000EASFx3DDRxSensLocalread-onlycurrentf2000EAS Series card fiber3 D/D information: Rx Sensitivity
1.3.6.1.4.1.4756.20.730.20.1.215Columnf2000EASFx3DDTxPWRLocalread-onlycurrentf2000EAS Series card fiber3 D/D information: Tx power
1.3.6.1.4.1.4756.20.730.20.1.216Columnf2000EASFx3DDRxPWRLocalread-onlycurrentf2000EAS Series card fiber3 D/D information: Rx power
1.3.6.1.4.1.4756.20.730.20.1.217Columnf2000EASFx3DDTempLocalread-onlycurrentf2000EAS Series card fiber3 D/D information: Temperature in degree C
1.3.6.1.4.1.4756.20.730.20.1.218Columnf2000EASFx3DDPWRMarginLocalread-onlycurrentf2000EAS Series card fiber3 D/D information: Power margin
1.3.6.1.4.1.4756.20.730.20.1.219Columnf2000EASFx3DDPWRLossLocalread-onlycurrentf2000EAS Series card fiber3 D/D information: Power loss
1.3.6.1.4.1.4756.20.730.20.1.220Columnf2000EASFx4DDLocalread-onlycurrentf2000EAS Series card fiber4 Digital Diagnostic function: 0:NO 1:Yes
1.3.6.1.4.1.4756.20.730.20.1.221Columnf2000EASFx4DDVendorLocalread-onlycurrentf2000EAS Series card fiber4 D/D information: Vendor name
1.3.6.1.4.1.4756.20.730.20.1.222Columnf2000EASFx4DDPartNoLocalread-onlycurrentf2000EAS Series card fiber4 D/D information: Vendor part number
1.3.6.1.4.1.4756.20.730.20.1.223Columnf2000EASFx4DDFiberTypeLocalread-onlycurrentf2000EAS Series card fiber4 D/D information: Fiber Type
1.3.6.1.4.1.4756.20.730.20.1.224Columnf2000EASFx4DDWaveLenLocalread-onlycurrentf2000EAS Series card fiber4 D/D information: Wave length 1
1.3.6.1.4.1.4756.20.730.20.1.225Columnf2000EASFx4DDWaveLen2Localread-onlycurrentf2000EAS Series card fiber4 D/D information: Wave length 2
1.3.6.1.4.1.4756.20.730.20.1.226Columnf2000EASFx4DDLinkLenLocalread-onlycurrentf2000EAS Series card fiber4 D/D information: Link length
1.3.6.1.4.1.4756.20.730.20.1.227Columnf2000EASFx4DDLenUnitLocalread-onlycurrentf2000EAS Series card fiber4 D/D information: Length Unit
1.3.6.1.4.1.4756.20.730.20.1.228Columnf2000EASFx4DDStatusLocalread-onlycurrentf2000EAS Series card fiber4 D/D information: Status Support
1.3.6.1.4.1.4756.20.730.20.1.229Columnf2000EASFx4DDRxSensLocalread-onlycurrentf2000EAS Series card fiber4 D/D information: Rx Sensitivity
1.3.6.1.4.1.4756.20.730.20.1.230Columnf2000EASFx4DDTxPWRLocalread-onlycurrentf2000EAS Series card fiber4 D/D information: Tx power
1.3.6.1.4.1.4756.20.730.20.1.231Columnf2000EASFx4DDRxPWRLocalread-onlycurrentf2000EAS Series card fiber4 D/D information: Rx power
1.3.6.1.4.1.4756.20.730.20.1.232Columnf2000EASFx4DDTempLocalread-onlycurrentf2000EAS Series card fiber4 D/D information: Temperature in degree C
1.3.6.1.4.1.4756.20.730.20.1.233Columnf2000EASFx4DDPWRMarginLocalread-onlycurrentf2000EAS Series card fiber4 D/D information: Power margin
1.3.6.1.4.1.4756.20.730.20.1.234Columnf2000EASFx4DDPWRLossLocalread-onlycurrentf2000EAS Series card fiber4 D/D information: Power loss
1.3.6.1.4.1.4756.20.730.20.1.235Columnf2000EASTestLocalread-onlycurrentf2000EAS Series card test led sts: 0: Off 1: On
1.3.6.1.4.1.4756.20.730.20.1.236Columnf2000EASClearPortCounterLocalread-writecurrentf2000EAS Series card clear port counter: 0: Off 1: Action
1.3.6.1.4.1.4756.20.730.20.1.237Columnf2000EASAggrSourceMACAddrLocalread-writecurrentf2000EAS Series card Aggregation Mode Configuration: Source MAC Address 0: No 1: Yes
1.3.6.1.4.1.4756.20.730.20.1.238Columnf2000EASAggrDestinationMACAddrLocalread-writecurrentf2000EAS Series card Aggregation Mode Configuration: Destination MAC Address 0: No 1: Yes
1.3.6.1.4.1.4756.20.730.20.1.239Columnf2000EASAggrIPAddrLocalread-writecurrentf2000EAS Series card Aggregation Mode Configuration: IP Address 0: No 1: Yes
1.3.6.1.4.1.4756.20.730.20.1.240Columnf2000EASAggrTCPUDPPortNumLocalread-writecurrentf2000EAS Series card Aggregation Mode Configuration: TCP/UDP Port Number 0: No 1: Yes
1.3.6.1.4.1.4756.20.730.20.1.241Columnf2000EASAggrGroupPort1ConfLocalread-writecurrentf2000EAS Series card Aggregation Group Port1 Configuration: 0: Normal 1: ID1 2: ID2
1.3.6.1.4.1.4756.20.730.20.1.242Columnf2000EASAggrGroupPort2ConfLocalread-writecurrentf2000EAS Series card Aggregation Group Port2 Configuration: 0: Normal 1: ID1 2: ID2
1.3.6.1.4.1.4756.20.730.20.1.243Columnf2000EASAggrGroupPort3ConfLocalread-writecurrentf2000EAS Series card Aggregation Group Port3 Configuration: 0: Normal 1: ID1 2: ID2
1.3.6.1.4.1.4756.20.730.20.1.244Columnf2000EASAggrGroupPort4ConfLocalread-writecurrentf2000EAS Series card Aggregation Group Port4 Configuration: 0: Normal 1: ID1 2: ID2
1.3.6.1.4.1.4756.20.730.20.1.245Columnf2000EASPort1LACPEnabledLocalread-writecurrentf2000EAS Series card Port1 LACP Enabled: 0: No 1: Yes
1.3.6.1.4.1.4756.20.730.20.1.246Columnf2000EASPort1LACPKEYLocalread-writecurrentf2000EAS Series card Port1 LACP Key value: The Key value incurred by the port, range 0-65535.The value of 0 means auto.
1.3.6.1.4.1.4756.20.730.20.1.247Columnf2000EASPort1LACPRoleLocalread-writecurrentf2000EAS Series card Port1 LACP Role: 0: Passive 1: Active
1.3.6.1.4.1.4756.20.730.20.1.248Columnf2000EASPort1LACPTimeOutLocalread-writecurrentf2000EAS Series card Port1 LACP Time out: 0: Slow 1: Fast
1.3.6.1.4.1.4756.20.730.20.1.249Columnf2000EASPort1LACPPrioLocalread-writecurrentf2000EAS Series card Port1 LACP priority: The Key value incurred by the port, range 1-65535.
1.3.6.1.4.1.4756.20.730.20.1.250Columnf2000EASPort2LACPEnabledLocalread-writecurrentf2000EAS Series card Port2 LACP Enabled: 0: No 1: Yes
1.3.6.1.4.1.4756.20.730.20.1.251Columnf2000EASPort2LACPKEYLocalread-writecurrentf2000EAS Series card Port2 LACP Key value: The Key value incurred by the port, range 0-65535.The value of 0 means auto.
1.3.6.1.4.1.4756.20.730.20.1.252Columnf2000EASPort2LACPRoleLocalread-writecurrentf2000EAS Series card Port2 LACP Role: 0: Passive 1: Active
1.3.6.1.4.1.4756.20.730.20.1.253Columnf2000EASPort2LACPTimeOutLocalread-writecurrentf2000EAS Series card Port2 LACP Time out: 0: Slow 1: Fast
1.3.6.1.4.1.4756.20.730.20.1.254Columnf2000EASPort2LACPPrioLocalread-writecurrentf2000EAS Series card Port2 LACP priority: The Key value incurred by the port, range 1-65535.
1.3.6.1.4.1.4756.20.730.20.1.255Columnf2000EASPort3LACPEnabledLocalread-writecurrentf2000EAS Series card Port3 LACP Enabled: 0: No 1: Yes
1.3.6.1.4.1.4756.20.730.20.1.256Columnf2000EASPort3LACPKEYLocalread-writecurrentf2000EAS Series card Port3 LACP Key value: The Key value incurred by the port, range 0-65535.The value of 0 means auto.
1.3.6.1.4.1.4756.20.730.20.1.257Columnf2000EASPort3LACPRoleLocalread-writecurrentf2000EAS Series card Port3 LACP Role: 0: Passive 1: Active
1.3.6.1.4.1.4756.20.730.20.1.258Columnf2000EASPort3LACPTimeOutLocalread-writecurrentf2000EAS Series card Port3 LACP Time out: 0: Slow 1: Fast
1.3.6.1.4.1.4756.20.730.20.1.259Columnf2000EASPort3LACPPrioLocalread-writecurrentf2000EAS Series card Port3 LACP priority: The Key value incurred by the port, range 1-65535.
1.3.6.1.4.1.4756.20.730.20.1.260Columnf2000EASPort4LACPEnabledLocalread-writecurrentf2000EAS Series card Port4 LACP Enabled: 0: No 1: Yes
1.3.6.1.4.1.4756.20.730.20.1.261Columnf2000EASPort4LACPKEYLocalread-writecurrentf2000EAS Series card Port4 LACP Key value: The Key value incurred by the port, range 0-65535.The value of 0 means auto.
1.3.6.1.4.1.4756.20.730.20.1.262Columnf2000EASPort4LACPRoleLocalread-writecurrentf2000EAS Series card Port4 LACP Role: 0: Passive 1: Active
1.3.6.1.4.1.4756.20.730.20.1.263Columnf2000EASPort4LACPTimeOutLocalread-writecurrentf2000EAS Series card Port4 LACP Time out: 0: Slow 1: Fast
1.3.6.1.4.1.4756.20.730.20.1.264Columnf2000EASPort4LACPPrioLocalread-writecurrentf2000EAS Series card Port4 LACP priority: The Key value incurred by the port, range 1-65535.
1.3.6.1.4.1.4756.20.730.20.1.265Columnf2000EASPort1LACPstsLocalread-onlycurrentf2000EAS Series card Port1 LACP status: 0: No 1: Yes 2: Standby
1.3.6.1.4.1.4756.20.730.20.1.266Columnf2000EASPort1LACPKEYstsLocalread-onlycurrentf2000EAS Series card Port1 LACP status: Key
1.3.6.1.4.1.4756.20.730.20.1.267Columnf2000EASPort1LACPAggrIDstsLocalread-onlycurrentf2000EAS Series card Port1 LACP status: Aggr ID
1.3.6.1.4.1.4756.20.730.20.1.268Columnf2000EASPort1LACPParnterSysIDstsLocalread-onlycurrentf2000EAS Series card Port1 LACP status: Parnter System ID
1.3.6.1.4.1.4756.20.730.20.1.269Columnf2000EASPort1LACPParnterPortstsLocalread-onlycurrentf2000EAS Series card Port1 LACP status: Parnter Port Status
1.3.6.1.4.1.4756.20.730.20.1.270Columnf2000EASPort1LACPParnterProistsLocalread-onlycurrentf2000EAS Series card Port1 LACP status: Parnter Priority
1.3.6.1.4.1.4756.20.730.20.1.271Columnf2000EASPort2LACPstsLocalread-onlycurrentf2000EAS Series card Port2 LACP status: 0: No 1: Yes 2: Standby
1.3.6.1.4.1.4756.20.730.20.1.272Columnf2000EASPort2LACPKEYstsLocalread-onlycurrentf2000EAS Series card Port2 LACP status: Key
1.3.6.1.4.1.4756.20.730.20.1.273Columnf2000EASPort2LACPAggrIDstsLocalread-onlycurrentf2000EAS Series card Port2 LACP status: Aggr ID
1.3.6.1.4.1.4756.20.730.20.1.274Columnf2000EASPort2LACPParnterSysIDstsLocalread-onlycurrentf2000EAS Series card Port2 LACP status: Parnter System ID
1.3.6.1.4.1.4756.20.730.20.1.275Columnf2000EASPort2LACPParnterPortstsLocalread-onlycurrentf2000EAS Series card Port2 LACP status: Parnter Port Status
1.3.6.1.4.1.4756.20.730.20.1.276Columnf2000EASPort2LACPParnterProistsLocalread-onlycurrentf2000EAS Series card Port2 LACP status: Parnter Priority
1.3.6.1.4.1.4756.20.730.20.1.277Columnf2000EASPort3LACPstsLocalread-onlycurrentf2000EAS Series card Port3 LACP status: 0: No 1: Yes 2: Standby
1.3.6.1.4.1.4756.20.730.20.1.278Columnf2000EASPort3LACPKEYstsLocalread-onlycurrentf2000EAS Series card Port3 LACP status: Key
1.3.6.1.4.1.4756.20.730.20.1.279Columnf2000EASPort3LACPAggrIDstsLocalread-onlycurrentf2000EAS Series card Port3 LACP status: Aggr ID
1.3.6.1.4.1.4756.20.730.20.1.280Columnf2000EASPort3LACPParnterSysIDstsLocalread-onlycurrentf2000EAS Series card Port3 LACP status: Parnter System ID
1.3.6.1.4.1.4756.20.730.20.1.281Columnf2000EASPort3LACPParnterPortstsLocalread-onlycurrentf2000EAS Series card Port3 LACP status: Parnter Port Status
1.3.6.1.4.1.4756.20.730.20.1.282Columnf2000EASPort3LACPParnterProistsLocalread-onlycurrentf2000EAS Series card Port3 LACP status: Parnter Priority
1.3.6.1.4.1.4756.20.730.20.1.283Columnf2000EASPort4LACPstsLocalread-onlycurrentf2000EAS Series card Port4 LACP status: 0: No 1: Yes 2: Standby
1.3.6.1.4.1.4756.20.730.20.1.284Columnf2000EASPort4LACPKEYstsLocalread-onlycurrentf2000EAS Series card Port4 LACP status: Key
1.3.6.1.4.1.4756.20.730.20.1.285Columnf2000EASPort4LACPAggrIDstsLocalread-onlycurrentf2000EAS Series card Port4 LACP status: Aggr ID
1.3.6.1.4.1.4756.20.730.20.1.286Columnf2000EASPort4LACPParnterSysIDstsLocalread-onlycurrentf2000EAS Series card Port4 LACP status: Parnter System ID
1.3.6.1.4.1.4756.20.730.20.1.287Columnf2000EASPort4LACPParnterPortstsLocalread-onlycurrentf2000EAS Series card Port4 LACP status: Parnter Port Status
1.3.6.1.4.1.4756.20.730.20.1.288Columnf2000EASPort4LACPParnterProistsLocalread-onlycurrentf2000EAS Series card Port4 LACP status: Parnter Priority
1.3.6.1.4.1.4756.20.730.20.1.289Columnf2000EASOAMPort1EnableLocalread-writecurrentf2000EAS Series card Port1 OAM: 0: Off 1: On
1.3.6.1.4.1.4756.20.730.20.1.290Columnf2000EASOAMPort1ModeLocalread-writecurrentf2000EAS Series card Port1 OAM: 0: Passive 1: Active
1.3.6.1.4.1.4756.20.730.20.1.291Columnf2000EASOAMPort1LoopBackLocalread-writecurrentf2000EAS Series card Port1 OAM LoopBack: 0: Off 1: On
1.3.6.1.4.1.4756.20.730.20.1.292Columnf2000EASOAMPort1LinkMonitorLocalread-writecurrentf2000EAS Series card Port1 OAM Link Monitor: 0: Off 1: On
1.3.6.1.4.1.4756.20.730.20.1.293Columnf2000EASOAMPort1MIBRetrievalLocalread-writecurrentf2000EAS Series card Port1 OAM MIB Retrieval: 0: Off 1: On
1.3.6.1.4.1.4756.20.730.20.1.294Columnf2000EASOAMPort1LoopBackOPLocalread-onlycurrentf2000EAS Series card Port1 OAM LoopBack operation: 0: Off 1: On
1.3.6.1.4.1.4756.20.730.20.1.295Columnf2000EASOAMPort2EnableLocalread-writecurrentf2000EAS Series card Port2 OAM: 0: Off 1: On
1.3.6.1.4.1.4756.20.730.20.1.296Columnf2000EASOAMPort2ModeLocalread-writecurrentf2000EAS Series card Port2 OAM: 0: Passive 1: Active
1.3.6.1.4.1.4756.20.730.20.1.297Columnf2000EASOAMPort2LoopBackLocalread-writecurrentf2000EAS Series card Port2 OAM LoopBack: 0: Off 1: On
1.3.6.1.4.1.4756.20.730.20.1.298Columnf2000EASOAMPort2LinkMonitorLocalread-writecurrentf2000EAS Series card Port2 OAM Link Monitor: 0: Off 1: On
1.3.6.1.4.1.4756.20.730.20.1.299Columnf2000EASOAMPort2MIBRetrievalLocalread-writecurrentf2000EAS Series card Port2 OAM MIB Retrieval: 0: Off 1: On
1.3.6.1.4.1.4756.20.730.20.1.300Columnf2000EASOAMPort2LoopBackOPLocalread-onlycurrentf2000EAS Series card Port2 OAM LoopBack operation: 0: Off 1: On
1.3.6.1.4.1.4756.20.730.20.1.301Columnf2000EASOAMPort3EnableLocalread-writecurrentf2000EAS Series card Port3 OAM: 0: Off 1: On
1.3.6.1.4.1.4756.20.730.20.1.302Columnf2000EASOAMPort3ModeLocalread-writecurrentf2000EAS Series card Port3 OAM: 0: Passive 1: Active
1.3.6.1.4.1.4756.20.730.20.1.303Columnf2000EASOAMPort3LoopBackLocalread-writecurrentf2000EAS Series card Port3 OAM: 0: Off 1: On
1.3.6.1.4.1.4756.20.730.20.1.304Columnf2000EASOAMPort3LinkMonitorLocalread-writecurrentf2000EAS Series card Port3 OAM Link Monitor: 0: Off 1: On
1.3.6.1.4.1.4756.20.730.20.1.305Columnf2000EASOAMPort3MIBRetrievalLocalread-writecurrentf2000EAS Series card Port3 OAM MIB Retrieval: 0: Off 1: On
1.3.6.1.4.1.4756.20.730.20.1.306Columnf2000EASOAMPort3LoopBackOPLocalread-onlycurrentf2000EAS Series card Port3 OAM LoopBack operation: 0: Disable 1: Enable
1.3.6.1.4.1.4756.20.730.20.1.307Columnf2000EASOAMPort4EnableLocalread-writecurrentf2000EAS Series card Port4 OAM: 0: Off 1: On
1.3.6.1.4.1.4756.20.730.20.1.308Columnf2000EASOAMPort4ModeLocalread-writecurrentf2000EAS Series card Port4 OAM: 0: Passive 1: Active
1.3.6.1.4.1.4756.20.730.20.1.309Columnf2000EASOAMPort4LoopBackLocalread-writecurrentf2000EAS Series card Port4 OAM: 0: Off 1: On
1.3.6.1.4.1.4756.20.730.20.1.310Columnf2000EASOAMPort4LinkMonitorLocalread-writecurrentf2000EAS Series card Port4 OAM Link Monitor: 0: Off 1: On
1.3.6.1.4.1.4756.20.730.20.1.311Columnf2000EASOAMPort4MIBRetrievalLocalread-writecurrentf2000EAS Series card Port4 OAM MIB Retrieval: 0: Off 1: On
1.3.6.1.4.1.4756.20.730.20.1.312Columnf2000EASOAMPort4LoopBackOPLocalread-onlycurrentf2000EAS Series card Port4 OAM LoopBack operation: 0: On 1: Off
1.3.6.1.4.1.4756.20.730.20.1.313Columnf2000EASPort1EFEErrorWindowLocalread-writecurrentf2000EAS Series card Port1 Link Event Configuration: Error Frame Event - Error Window
1.3.6.1.4.1.4756.20.730.20.1.314Columnf2000EASPort1EFEErrorThresholdLocalread-writecurrentf2000EAS Series card Port1 Link Event Configuration: Error Frame Event - Error Threshold
1.3.6.1.4.1.4756.20.730.20.1.315Columnf2000EASPort1SPEEErrorWindowLocalread-writecurrentf2000EAS Series card Port1 Link Event Configuration: Symbol Period Error Event - Error Window
1.3.6.1.4.1.4756.20.730.20.1.316Columnf2000EASPort1SPEEErrorThresholdLocalread-writecurrentf2000EAS Series card Port1 Link Event Configuration: Symbol Period Error Event - Error Threshold
1.3.6.1.4.1.4756.20.730.20.1.317Columnf2000EASPort1SSEErrorWindowLocalread-writecurrentf2000EAS Series card Port1 Link Event Configuration: Seconds Summary Event - Error Window
1.3.6.1.4.1.4756.20.730.20.1.318Columnf2000EASPort1SSEErrorThresholdLocalread-writecurrentf2000EAS Series card Port1 Link Event Configuration: Seconds Summary Event - Error Threshold
1.3.6.1.4.1.4756.20.730.20.1.319Columnf2000EASPort2EFEErrorWindowLocalread-writecurrentf2000EAS Series card Port2 Link Event Configuration: Error Frame Event - Error Window
1.3.6.1.4.1.4756.20.730.20.1.320Columnf2000EASPort2EFEErrorThresholdLocalread-writecurrentf2000EAS Series card Port2 Link Event Configuration: Error Frame Event - Error Threshold
1.3.6.1.4.1.4756.20.730.20.1.321Columnf2000EASPort2SPEEErrorWindowLocalread-writecurrentf2000EAS Series card Port2 Link Event Configuration: Symbol Period Error Event - Error Window
1.3.6.1.4.1.4756.20.730.20.1.322Columnf2000EASPort2SPEEErrorThresholdLocalread-writecurrentf2000EAS Series card Port2 Link Event Configuration: Symbol Period Error Event - Error Threshold
1.3.6.1.4.1.4756.20.730.20.1.323Columnf2000EASPort2SSEErrorWindowLocalread-writecurrentf2000EAS Series card Port2 Link Event Configuration: Seconds Summary Event - Error Window
1.3.6.1.4.1.4756.20.730.20.1.324Columnf2000EASPort2SSEErrorThresholdLocalread-writecurrentf2000EAS Series card Port2 Link Event Configuration: Seconds Summary Event - Error Threshold
1.3.6.1.4.1.4756.20.730.20.1.325Columnf2000EASPort3EFEErrorWindowLocalread-writecurrentf2000EAS Series card Port3 Link Event Configuration: Error Frame Event - Error Window
1.3.6.1.4.1.4756.20.730.20.1.326Columnf2000EASPort3EFEErrorThresholdLocalread-writecurrentf2000EAS Series card Port3 Link Event Configuration: Error Frame Event - Error Threshold
1.3.6.1.4.1.4756.20.730.20.1.327Columnf2000EASPort3SPEEErrorWindowLocalread-writecurrentf2000EAS Series card Port3 Link Event Configuration: Symbol Period Error Event - Error Window
1.3.6.1.4.1.4756.20.730.20.1.328Columnf2000EASPort3SPEEErrorThresholdLocalread-writecurrentf2000EAS Series card Port3 Link Event Configuration: Symbol Period Error Event - Error Threshold
1.3.6.1.4.1.4756.20.730.20.1.329Columnf2000EASPort3SSEErrorWindowLocalread-writecurrentf2000EAS Series card Port3 Link Event Configuration: Seconds Summary Event - Error Window
1.3.6.1.4.1.4756.20.730.20.1.330Columnf2000EASPort3SSEErrorThresholdLocalread-writecurrentf2000EAS Series card Port3 Link Event Configuration: Seconds Summary Event - Error Threshold
1.3.6.1.4.1.4756.20.730.20.1.331Columnf2000EASPort4EFEErrorWindowLocalread-writecurrentf2000EAS Series card Port4 Link Event Configuration: Error Frame Event - Error Window
1.3.6.1.4.1.4756.20.730.20.1.332Columnf2000EASPort4EFEErrorThresholdLocalread-writecurrentf2000EAS Series card Port4 Link Event Configuration: Error Frame Event - Error Threshold
1.3.6.1.4.1.4756.20.730.20.1.333Columnf2000EASPort4SPEEErrorWindowLocalread-writecurrentf2000EAS Series card Port4 Link Event Configuration: Symbol Period Error Event - Error Window
1.3.6.1.4.1.4756.20.730.20.1.334Columnf2000EASPort4SPEEErrorThresholdLocalread-writecurrentf2000EAS Series card Port4 Link Event Configuration: Symbol Period Error Event - Error Threshold
1.3.6.1.4.1.4756.20.730.20.1.335Columnf2000EASPort4SSEErrorWindowLocalread-writecurrentf2000EAS Series card Port4 Link Event Configuration: Seconds Summary Event - Error Window
1.3.6.1.4.1.4756.20.730.20.1.336Columnf2000EASPort4SSEErrorThresholdLocalread-writecurrentf2000EAS Series card Port4 Link Event Configuration: Seconds Summary Event - Error Threshold
1.3.6.1.4.1.4756.20.730.20.1.337Columnf2000EASPort1RxOAMInfoPDULocalread-onlycurrentf2000EAS Series card Port1 Detailed Link OAM Statistics: Rx OAM Information PDU's
1.3.6.1.4.1.4756.20.730.20.1.338Columnf2000EASPort1RxUniqueErrorEventLocalread-onlycurrentf2000EAS Series card Port1 Detailed Link OAM Statistics: Rx Unique Error Event Notificatio
1.3.6.1.4.1.4756.20.730.20.1.339Columnf2000EASPort1RxDuplicateErrorEventLocalread-onlycurrentf2000EAS Series card Port1 Detailed Link OAM Statistics: Rx Duplicate Error Event Notification
1.3.6.1.4.1.4756.20.730.20.1.340Columnf2000EASPort1RxLoopBackControlLocalread-onlycurrentf2000EAS Series card Port1 Detailed Link OAM Statistics: Rx Loopback Control
1.3.6.1.4.1.4756.20.730.20.1.341Columnf2000EASPort1RxVariableRequestLocalread-onlycurrentf2000EAS Series card Port1 Detailed Link OAM Statistics: Rx Variable Request
1.3.6.1.4.1.4756.20.730.20.1.342Columnf2000EASPort1RxVariableResponseLocalread-onlycurrentf2000EAS Series card Port1 Detailed Link OAM Statistics: Rx Variable Response
1.3.6.1.4.1.4756.20.730.20.1.343Columnf2000EASPort1RxOrgSpecificPDULocalread-onlycurrentf2000EAS Series card Port1 Detailed Link OAM Statistics: Rx Org Specific PDU's
1.3.6.1.4.1.4756.20.730.20.1.344Columnf2000EASPort1RxUnsupportedCodesLocalread-onlycurrentf2000EAS Series card Port1 Detailed Link OAM Statistics: Rx Unsupported Codes
1.3.6.1.4.1.4756.20.730.20.1.345Columnf2000EASPort1RxLinkFaultPDULocalread-onlycurrentf2000EAS Series card Port1 Detailed Link OAM Statistics: Rx Link Fault PDU's
1.3.6.1.4.1.4756.20.730.20.1.346Columnf2000EASPort1RxDyingGaspLocalread-onlycurrentf2000EAS Series card Port1 Detailed Link OAM Statistics: Rx Dying Gasp
1.3.6.1.4.1.4756.20.730.20.1.347Columnf2000EASPort1RxCriticalEventPDULocalread-onlycurrentf2000EAS Series card Port1 Detailed Link OAM Statistics: Rx Dying Gasp
1.3.6.1.4.1.4756.20.730.20.1.348Columnf2000EASPort1TxOAMInfoPDULocalread-onlycurrentf2000EAS Series card Port1 Detailed Link OAM Statistics: Tx OAM Information PDU's
1.3.6.1.4.1.4756.20.730.20.1.349Columnf2000EASPort1TxUniqueErrorEventLocalread-onlycurrentf2000EAS Series card Port1 Detailed Link OAM Statistics: Tx Unique Error Event Notificatio
1.3.6.1.4.1.4756.20.730.20.1.350Columnf2000EASPort1TxDuplicateErrorEventLocalread-onlycurrentf2000EAS Series card Port1 Detailed Link OAM Statistics: Tx Duplicate Error Event Notification
1.3.6.1.4.1.4756.20.730.20.1.351Columnf2000EASPort1TxLoopBackControlLocalread-onlycurrentf2000EAS Series card Port1 Detailed Link OAM Statistics: Tx Loopback Control
1.3.6.1.4.1.4756.20.730.20.1.352Columnf2000EASPort1TxVariableRequestLocalread-onlycurrentf2000EAS Series card Port1 Detailed Link OAM Statistics: Tx Variable Request
1.3.6.1.4.1.4756.20.730.20.1.353Columnf2000EASPort1TxVariableResponseLocalread-onlycurrentf2000EAS Series card Port1 Detailed Link OAM Statistics: Tx Variable Response
1.3.6.1.4.1.4756.20.730.20.1.354Columnf2000EASPort1TxOrgSpecificPDULocalread-onlycurrentf2000EAS Series card Port1 Detailed Link OAM Statistics: Tx Org Specific PDU's
1.3.6.1.4.1.4756.20.730.20.1.355Columnf2000EASPort1TxUnsupportedCodesLocalread-onlycurrentf2000EAS Series card Port1 Detailed Link OAM Statistics: Tx Unsupported Codes
1.3.6.1.4.1.4756.20.730.20.1.356Columnf2000EASPort1TxLinkFaultPDULocalread-onlycurrentf2000EAS Series card Port1 Detailed Link OAM Statistics: Tx Link Fault PDU's
1.3.6.1.4.1.4756.20.730.20.1.357Columnf2000EASPort1TxDyingGaspLocalread-onlycurrentf2000EAS Series card Port1 Detailed Link OAM Statistics: Tx Dying Gasp
1.3.6.1.4.1.4756.20.730.20.1.358Columnf2000EASPort1TxCriticalEventPDULocalread-onlycurrentf2000EAS Series card Port1 Detailed Link OAM Statistics: Tx Dying Gasp
1.3.6.1.4.1.4756.20.730.20.1.359Columnf2000EASPort2RxOAMInfoPDULocalread-onlycurrentf2000EAS Series card Port2 Detailed Link OAM Statistics: Rx OAM Information PDU's
1.3.6.1.4.1.4756.20.730.20.1.360Columnf2000EASPort2RxUniqueErrorEventLocalread-onlycurrentf2000EAS Series card Port2 Detailed Link OAM Statistics: Rx Unique Error Event Notificatio
1.3.6.1.4.1.4756.20.730.20.1.361Columnf2000EASPort2RxDuplicateErrorEventLocalread-onlycurrentf2000EAS Series card Port2 Detailed Link OAM Statistics: Rx Duplicate Error Event Notification
1.3.6.1.4.1.4756.20.730.20.1.362Columnf2000EASPort2RxLoopBackControlLocalread-onlycurrentf2000EAS Series card Port2 Detailed Link OAM Statistics: Rx Loopback Control
1.3.6.1.4.1.4756.20.730.20.1.363Columnf2000EASPort2RxVariableRequestLocalread-onlycurrentf2000EAS Series card Port2 Detailed Link OAM Statistics: Rx Variable Request
1.3.6.1.4.1.4756.20.730.20.1.364Columnf2000EASPort2RxVariableResponseLocalread-onlycurrentf2000EAS Series card Port2 Detailed Link OAM Statistics: Rx Variable Response
1.3.6.1.4.1.4756.20.730.20.1.365Columnf2000EASPort2RxOrgSpecificPDULocalread-onlycurrentf2000EAS Series card Port2 Detailed Link OAM Statistics: Rx Org Specific PDU's
1.3.6.1.4.1.4756.20.730.20.1.366Columnf2000EASPort2RxUnsupportedCodesLocalread-onlycurrentf2000EAS Series card Port2 Detailed Link OAM Statistics: Rx Unsupported Codes
1.3.6.1.4.1.4756.20.730.20.1.367Columnf2000EASPort2RxLinkFaultPDULocalread-onlycurrentf2000EAS Series card Port2 Detailed Link OAM Statistics: Rx Link Fault PDU's
1.3.6.1.4.1.4756.20.730.20.1.368Columnf2000EASPort2RxDyingGaspLocalread-onlycurrentf2000EAS Series card Port2 Detailed Link OAM Statistics: Rx Dying Gasp
1.3.6.1.4.1.4756.20.730.20.1.369Columnf2000EASPort2RxCriticalEventPDULocalread-onlycurrentf2000EAS Series card Port2 Detailed Link OAM Statistics: Rx Dying Gasp
1.3.6.1.4.1.4756.20.730.20.1.370Columnf2000EASPort2TxOAMInfoPDULocalread-onlycurrentf2000EAS Series card Port2 Detailed Link OAM Statistics: Tx OAM Information PDU's
1.3.6.1.4.1.4756.20.730.20.1.371Columnf2000EASPort2TxUniqueErrorEventLocalread-onlycurrentf2000EAS Series card Port2 Detailed Link OAM Statistics: Tx Unique Error Event Notificatio
1.3.6.1.4.1.4756.20.730.20.1.372Columnf2000EASPort2TxDuplicateErrorEventLocalread-onlycurrentf2000EAS Series card Port2 Detailed Link OAM Statistics: Tx Duplicate Error Event Notification
1.3.6.1.4.1.4756.20.730.20.1.373Columnf2000EASPort2TxLoopBackControlLocalread-onlycurrentf2000EAS Series card Port2 Detailed Link OAM Statistics: Tx Loopback Control
1.3.6.1.4.1.4756.20.730.20.1.374Columnf2000EASPort2TxVariableRequestLocalread-onlycurrentf2000EAS Series card Port2 Detailed Link OAM Statistics: Tx Variable Request
1.3.6.1.4.1.4756.20.730.20.1.375Columnf2000EASPort2TxVariableResponseLocalread-onlycurrentf2000EAS Series card Port2 Detailed Link OAM Statistics: Tx Variable Response
1.3.6.1.4.1.4756.20.730.20.1.376Columnf2000EASPort2TxOrgSpecificPDULocalread-onlycurrentf2000EAS Series card Port2 Detailed Link OAM Statistics: Tx Org Specific PDU's
1.3.6.1.4.1.4756.20.730.20.1.377Columnf2000EASPort2TxUnsupportedCodesLocalread-onlycurrentf2000EAS Series card Port2 Detailed Link OAM Statistics: Tx Unsupported Codes
1.3.6.1.4.1.4756.20.730.20.1.378Columnf2000EASPort2TxLinkFaultPDULocalread-onlycurrentf2000EAS Series card Port2 Detailed Link OAM Statistics: Tx Link Fault PDU's
1.3.6.1.4.1.4756.20.730.20.1.379Columnf2000EASPort2TxDyingGaspLocalread-onlycurrentf2000EAS Series card Port2 Detailed Link OAM Statistics: Tx Dying Gasp
1.3.6.1.4.1.4756.20.730.20.1.380Columnf2000EASPort2TxCriticalEventPDULocalread-onlycurrentf2000EAS Series card Port2 Detailed Link OAM Statistics: Tx Dying Gasp
1.3.6.1.4.1.4756.20.730.20.1.381Columnf2000EASPort3RxOAMInfoPDULocalread-onlycurrentf2000EAS Series card Port3 Detailed Link OAM Statistics: Rx OAM Information PDU's
1.3.6.1.4.1.4756.20.730.20.1.382Columnf2000EASPort3RxUniqueErrorEventLocalread-onlycurrentf2000EAS Series card Port3 Detailed Link OAM Statistics: Rx Unique Error Event Notificatio
1.3.6.1.4.1.4756.20.730.20.1.383Columnf2000EASPort3RxDuplicateErrorEventLocalread-onlycurrentf2000EAS Series card Port3 Detailed Link OAM Statistics: Rx Duplicate Error Event Notification
1.3.6.1.4.1.4756.20.730.20.1.384Columnf2000EASPort3RxLoopBackControlLocalread-onlycurrentf2000EAS Series card Port3 Detailed Link OAM Statistics: Rx Loopback Control
1.3.6.1.4.1.4756.20.730.20.1.385Columnf2000EASPort3RxVariableRequestLocalread-onlycurrentf2000EAS Series card Port3 Detailed Link OAM Statistics: Rx Variable Request
1.3.6.1.4.1.4756.20.730.20.1.386Columnf2000EASPort3RxVariableResponseLocalread-onlycurrentf2000EAS Series card Port3 Detailed Link OAM Statistics: Rx Variable Response
1.3.6.1.4.1.4756.20.730.20.1.387Columnf2000EASPort3RxOrgSpecificPDULocalread-onlycurrentf2000EAS Series card Port3 Detailed Link OAM Statistics: Rx Org Specific PDU's
1.3.6.1.4.1.4756.20.730.20.1.388Columnf2000EASPort3RxUnsupportedCodesLocalread-onlycurrentf2000EAS Series card Port3 Detailed Link OAM Statistics: Rx Unsupported Codes
1.3.6.1.4.1.4756.20.730.20.1.389Columnf2000EASPort3RxLinkFaultPDULocalread-onlycurrentf2000EAS Series card Port3 Detailed Link OAM Statistics: Rx Link Fault PDU's
1.3.6.1.4.1.4756.20.730.20.1.390Columnf2000EASPort3RxDyingGaspLocalread-onlycurrentf2000EAS Series card Port3 Detailed Link OAM Statistics: Rx Dying Gasp
1.3.6.1.4.1.4756.20.730.20.1.391Columnf2000EASPort3RxCriticalEventPDULocalread-onlycurrentf2000EAS Series card Port3 Detailed Link OAM Statistics: Rx Dying Gasp
1.3.6.1.4.1.4756.20.730.20.1.392Columnf2000EASPort3TxOAMInfoPDULocalread-onlycurrentf2000EAS Series card Port3 Detailed Link OAM Statistics: Tx OAM Information PDU's
1.3.6.1.4.1.4756.20.730.20.1.393Columnf2000EASPort3TxUniqueErrorEventLocalread-onlycurrentf2000EAS Series card Port3 Detailed Link OAM Statistics: Tx Unique Error Event Notificatio
1.3.6.1.4.1.4756.20.730.20.1.394Columnf2000EASPort3TxDuplicateErrorEventLocalread-onlycurrentf2000EAS Series card Port3 Detailed Link OAM Statistics: Tx Duplicate Error Event Notification
1.3.6.1.4.1.4756.20.730.20.1.395Columnf2000EASPort3TxLoopBackControlLocalread-onlycurrentf2000EAS Series card Port3 Detailed Link OAM Statistics: Tx Loopback Control
1.3.6.1.4.1.4756.20.730.20.1.396Columnf2000EASPort3TxVariableRequestLocalread-onlycurrentf2000EAS Series card Port3 Detailed Link OAM Statistics: Tx Variable Request
1.3.6.1.4.1.4756.20.730.20.1.397Columnf2000EASPort3TxVariableResponseLocalread-onlycurrentf2000EAS Series card Port3 Detailed Link OAM Statistics: Tx Variable Response
1.3.6.1.4.1.4756.20.730.20.1.398Columnf2000EASPort3TxOrgSpecificPDULocalread-onlycurrentf2000EAS Series card Port3 Detailed Link OAM Statistics: Tx Org Specific PDU's
1.3.6.1.4.1.4756.20.730.20.1.399Columnf2000EASPort3TxUnsupportedCodesLocalread-onlycurrentf2000EAS Series card Port3 Detailed Link OAM Statistics: Tx Unsupported Codes
1.3.6.1.4.1.4756.20.730.20.1.400Columnf2000EASPort3TxLinkFaultPDULocalread-onlycurrentf2000EAS Series card Port3 Detailed Link OAM Statistics: Tx Link Fault PDU's
1.3.6.1.4.1.4756.20.730.20.1.401Columnf2000EASPort3TxDyingGaspLocalread-onlycurrentf2000EAS Series card Port3 Detailed Link OAM Statistics: Tx Dying Gasp
1.3.6.1.4.1.4756.20.730.20.1.402Columnf2000EASPort3TxCriticalEventPDULocalread-onlycurrentf2000EAS Series card Port3 Detailed Link OAM Statistics: Tx Dying Gasp
1.3.6.1.4.1.4756.20.730.20.1.403Columnf2000EASPort4RxOAMInfoPDULocalread-onlycurrentf2000EAS Series card Port4 Detailed Link OAM Statistics: Rx OAM Information PDU's
1.3.6.1.4.1.4756.20.730.20.1.404Columnf2000EASPort4RxUniqueErrorEventLocalread-onlycurrentf2000EAS Series card Port4 Detailed Link OAM Statistics: Rx Unique Error Event Notificatio
1.3.6.1.4.1.4756.20.730.20.1.405Columnf2000EASPort4RxDuplicateErrorEventLocalread-onlycurrentf2000EAS Series card Port4 Detailed Link OAM Statistics: Rx Duplicate Error Event Notification
1.3.6.1.4.1.4756.20.730.20.1.406Columnf2000EASPort4RxLoopBackControlLocalread-onlycurrentf2000EAS Series card Port4 Detailed Link OAM Statistics: Rx Loopback Control
1.3.6.1.4.1.4756.20.730.20.1.407Columnf2000EASPort4RxVariableRequestLocalread-onlycurrentf2000EAS Series card Port4 Detailed Link OAM Statistics: Rx Variable Request
1.3.6.1.4.1.4756.20.730.20.1.408Columnf2000EASPort4RxVariableResponseLocalread-onlycurrentf2000EAS Series card Port4 Detailed Link OAM Statistics: Rx Variable Response
1.3.6.1.4.1.4756.20.730.20.1.409Columnf2000EASPort4RxOrgSpecificPDULocalread-onlycurrentf2000EAS Series card Port4 Detailed Link OAM Statistics: Rx Org Specific PDU's
1.3.6.1.4.1.4756.20.730.20.1.410Columnf2000EASPort4RxUnsupportedCodesLocalread-onlycurrentf2000EAS Series card Port4 Detailed Link OAM Statistics: Rx Unsupported Codes
1.3.6.1.4.1.4756.20.730.20.1.411Columnf2000EASPort4RxLinkFaultPDULocalread-onlycurrentf2000EAS Series card Port4 Detailed Link OAM Statistics: Rx Link Fault PDU's
1.3.6.1.4.1.4756.20.730.20.1.412Columnf2000EASPort4RxDyingGaspLocalread-onlycurrentf2000EAS Series card Port4 Detailed Link OAM Statistics: Rx Dying Gasp
1.3.6.1.4.1.4756.20.730.20.1.413Columnf2000EASPort4RxCriticalEventPDULocalread-onlycurrentf2000EAS Series card Port4 Detailed Link OAM Statistics: Rx Dying Gasp
1.3.6.1.4.1.4756.20.730.20.1.414Columnf2000EASPort4TxOAMInfoPDULocalread-onlycurrentf2000EAS Series card Port4 Detailed Link OAM Statistics: Tx OAM Information PDU's
1.3.6.1.4.1.4756.20.730.20.1.415Columnf2000EASPort4TxUniqueErrorEventLocalread-onlycurrentf2000EAS Series card Port4 Detailed Link OAM Statistics: Tx Unique Error Event Notificatio
1.3.6.1.4.1.4756.20.730.20.1.416Columnf2000EASPort4TxDuplicateErrorEventLocalread-onlycurrentf2000EAS Series card Port4 Detailed Link OAM Statistics: Tx Duplicate Error Event Notification
1.3.6.1.4.1.4756.20.730.20.1.417Columnf2000EASPort4TxLoopBackControlLocalread-onlycurrentf2000EAS Series card Port4 Detailed Link OAM Statistics: Tx Loopback Control
1.3.6.1.4.1.4756.20.730.20.1.418Columnf2000EASPort4TxVariableRequestLocalread-onlycurrentf2000EAS Series card Port4 Detailed Link OAM Statistics: Tx Variable Request
1.3.6.1.4.1.4756.20.730.20.1.419Columnf2000EASPort4TxVariableResponseLocalread-onlycurrentf2000EAS Series card Port4 Detailed Link OAM Statistics: Tx Variable Response
1.3.6.1.4.1.4756.20.730.20.1.420Columnf2000EASPort4TxOrgSpecificPDULocalread-onlycurrentf2000EAS Series card Port4 Detailed Link OAM Statistics: Tx Org Specific PDU's
1.3.6.1.4.1.4756.20.730.20.1.421Columnf2000EASPort4TxUnsupportedCodesLocalread-onlycurrentf2000EAS Series card Port4 Detailed Link OAM Statistics: Tx Unsupported Codes
1.3.6.1.4.1.4756.20.730.20.1.422Columnf2000EASPort4TxLinkFaultPDULocalread-onlycurrentf2000EAS Series card Port4 Detailed Link OAM Statistics: Tx Link Fault PDU's
1.3.6.1.4.1.4756.20.730.20.1.423Columnf2000EASPort4TxDyingGaspLocalread-onlycurrentf2000EAS Series card Port4 Detailed Link OAM Statistics: Tx Dying Gasp
1.3.6.1.4.1.4756.20.730.20.1.424Columnf2000EASPort4TxCriticalEventPDULocalread-onlycurrentf2000EAS Series card Port4 Detailed Link OAM Statistics: Tx Dying Gasp
1.3.6.1.4.1.4756.20.730.20.1.425Columnf2000EASPort1PDUPermisionLocalread-onlycurrentf2000EAS Series card Detailed Link OAM Status for Port 1: PDU Permission
1.3.6.1.4.1.4756.20.730.20.1.426Columnf2000EASPort1DiscoveryStateLocalread-onlycurrentf2000EAS Series card Detailed Link OAM Status for Port 1: Discovery State
1.3.6.1.4.1.4756.20.730.20.1.427Columnf2000EASPort1PeerMACAddrLocalread-onlycurrentf2000EAS Series card Detailed Link OAM Status for Port 1: Discovery State
1.3.6.1.4.1.4756.20.730.20.1.428Columnf2000EASPort1LocalModeLocalread-onlycurrentf2000EAS Series card Detailed Link OAM Status for Port 1: Local: Mode
1.3.6.1.4.1.4756.20.730.20.1.429Columnf2000EASPort1LocalUnOperationLocalread-onlycurrentf2000EAS Series card Detailed Link OAM Status for Port 1: Local: Unidirectional Operation Support
1.3.6.1.4.1.4756.20.730.20.1.430Columnf2000EASPort1LocalRemoteLbLocalread-onlycurrentf2000EAS Series card Detailed Link OAM Status for Port 1: Local: Remote Loopback Support
1.3.6.1.4.1.4756.20.730.20.1.431Columnf2000EASPort1LocalLMLocalread-onlycurrentf2000EAS Series card Detailed Link OAM Status for Port 1: RemoteA: Link Monitoring Support
1.3.6.1.4.1.4756.20.730.20.1.432Columnf2000EASPort1LocalMIBRetrievalLocalread-onlycurrentf2000EAS Series card Detailed Link OAM Status for Port 1: RemoteA: MIB Retrieval Support
1.3.6.1.4.1.4756.20.730.20.1.433Columnf2000EASPort1LocalMTUSizeLocalread-onlycurrentf2000EAS Series card Detailed Link OAM Status for Port 1: RemoteA: MTU Size
1.3.6.1.4.1.4756.20.730.20.1.434Columnf2000EASPort1LocalMultiStateLocalread-onlycurrentf2000EAS Series card Detailed Link OAM Status for Port 1: RemoteA: Multiplexer State
1.3.6.1.4.1.4756.20.730.20.1.435Columnf2000EASPort1LocalParserStateLocalread-onlycurrentf2000EAS Series card Detailed Link OAM Status for Port 1: RemoteA: Multiplexer State
1.3.6.1.4.1.4756.20.730.20.1.436Columnf2000EASPort1LocalOUILocalread-onlycurrentf2000EAS Series card Detailed Link OAM Status for Port 1: RemoteA: Organizational Unique Identification
1.3.6.1.4.1.4756.20.730.20.1.437Columnf2000EASPort1LocalPDURevLocalread-onlycurrentf2000EAS Series card Detailed Link OAM Status for Port 1: RemoteA: PDU Revision
1.3.6.1.4.1.4756.20.730.20.1.438Columnf2000EASPort1PeerModeLocalread-onlycurrentf2000EAS Series card Detailed Link OAM Status for Port 1: Peer: Mode
1.3.6.1.4.1.4756.20.730.20.1.439Columnf2000EASPort1PeerUnOperationLocalread-onlycurrentf2000EAS Series card Detailed Link OAM Status for Port 1: Peer: Unidirectional Operation Support
1.3.6.1.4.1.4756.20.730.20.1.440Columnf2000EASPort1PeerRemoteLbLocalread-onlycurrentf2000EAS Series card Detailed Link OAM Status for Port 1: Peer: Remote Loopback Support
1.3.6.1.4.1.4756.20.730.20.1.441Columnf2000EASPort1PeerLMLocalread-onlycurrentf2000EAS Series card Detailed Link OAM Status for Port 1: Peer: Link Monitoring Support
1.3.6.1.4.1.4756.20.730.20.1.442Columnf2000EASPort1PeerMIBRetrievalLocalread-onlycurrentf2000EAS Series card Detailed Link OAM Status for Port 1: Peer: MIB Retrieval Support
1.3.6.1.4.1.4756.20.730.20.1.443Columnf2000EASPort1PeerMTUSizeLocalread-onlycurrentf2000EAS Series card Detailed Link OAM Status for Port 1: Peer: MTU Size
1.3.6.1.4.1.4756.20.730.20.1.444Columnf2000EASPort1PeerMultiStateLocalread-onlycurrentf2000EAS Series card Detailed Link OAM Status for Port 1: Peer: Multiplexer State
1.3.6.1.4.1.4756.20.730.20.1.445Columnf2000EASPort1PeerParserStateLocalread-onlycurrentf2000EAS Series card Detailed Link OAM Status for Port 1: Peer: Multiplexer State
1.3.6.1.4.1.4756.20.730.20.1.446Columnf2000EASPort1PeerOUILocalread-onlycurrentf2000EAS Series card Detailed Link OAM Status for Port 1: Peer: Organizational Unique Identification
1.3.6.1.4.1.4756.20.730.20.1.447Columnf2000EASPort1PeerPDURevLocalread-onlycurrentf2000EAS Series card Detailed Link OAM Status for Port 1: Peer: PDU Revision
1.3.6.1.4.1.4756.20.730.20.1.448Columnf2000EASPort2PDUPermisionLocalread-onlycurrentf2000EAS Series card Detailed Link OAM Status for Port 2: PDU Permission
1.3.6.1.4.1.4756.20.730.20.1.449Columnf2000EASPort2DiscoveryStateLocalread-onlycurrentf2000EAS Series card Detailed Link OAM Status for Port 2: Discovery State
1.3.6.1.4.1.4756.20.730.20.1.450Columnf2000EASPort2PeerMACAddrLocalread-onlycurrentf2000EAS Series card Detailed Link OAM Status for Port 2: Discovery State
1.3.6.1.4.1.4756.20.730.20.1.451Columnf2000EASPort2LocalModeLocalread-onlycurrentf2000EAS Series card Detailed Link OAM Status for Port 2: RemoteA: Mode
1.3.6.1.4.1.4756.20.730.20.1.452Columnf2000EASPort2LocalUnOperationLocalread-onlycurrentf2000EAS Series card Detailed Link OAM Status for Port 2: RemoteA: Unidirectional Operation Support
1.3.6.1.4.1.4756.20.730.20.1.453Columnf2000EASPort2LocalRemoteLbLocalread-onlycurrentf2000EAS Series card Detailed Link OAM Status for Port 2: RemoteA: Remote Loopback Support
1.3.6.1.4.1.4756.20.730.20.1.454Columnf2000EASPort2LocalLMLocalread-onlycurrentf2000EAS Series card Detailed Link OAM Status for Port 2: RemoteA: Link Monitoring Support
1.3.6.1.4.1.4756.20.730.20.1.455Columnf2000EASPort2LocalMIBRetrievalLocalread-onlycurrentf2000EAS Series card Detailed Link OAM Status for Port 2: RemoteA: MIB Retrieval Support
1.3.6.1.4.1.4756.20.730.20.1.456Columnf2000EASPort2LocalMTUSizeLocalread-onlycurrentf2000EAS Series card Detailed Link OAM Status for Port 2: RemoteA: MTU Size
1.3.6.1.4.1.4756.20.730.20.1.457Columnf2000EASPort2LocalMultiStateLocalread-onlycurrentf2000EAS Series card Detailed Link OAM Status for Port 2: RemoteA: Multiplexer State
1.3.6.1.4.1.4756.20.730.20.1.458Columnf2000EASPort2LocalParserStateLocalread-onlycurrentf2000EAS Series card Detailed Link OAM Status for Port 2: RemoteA: Multiplexer State
1.3.6.1.4.1.4756.20.730.20.1.459Columnf2000EASPort2LocalOUILocalread-onlycurrentf2000EAS Series card Detailed Link OAM Status for Port 2: RemoteA: Organizational Unique Identification
1.3.6.1.4.1.4756.20.730.20.1.460Columnf2000EASPort2LocalPDURevLocalread-onlycurrentf2000EAS Series card Detailed Link OAM Status for Port 2: RemoteA: PDU Revision
1.3.6.1.4.1.4756.20.730.20.1.461Columnf2000EASPort2PeerModeLocalread-onlycurrentf2000EAS Series card Detailed Link OAM Status for Port 2: Peer: Mode
1.3.6.1.4.1.4756.20.730.20.1.462Columnf2000EASPort2PeerUnOperationLocalread-onlycurrentf2000EAS Series card Detailed Link OAM Status for Port 2: Peer: Unidirectional Operation Support
1.3.6.1.4.1.4756.20.730.20.1.463Columnf2000EASPort2PeerRemoteLbLocalread-onlycurrentf2000EAS Series card Detailed Link OAM Status for Port 2: Peer: Remote Loopback Support
1.3.6.1.4.1.4756.20.730.20.1.464Columnf2000EASPort2PeerLMLocalread-onlycurrentf2000EAS Series card Detailed Link OAM Status for Port 2: Peer: Link Monitoring Support
1.3.6.1.4.1.4756.20.730.20.1.465Columnf2000EASPort2PeerMIBRetrievalLocalread-onlycurrentf2000EAS Series card Detailed Link OAM Status for Port 2: Peer: MIB Retrieval Support
1.3.6.1.4.1.4756.20.730.20.1.466Columnf2000EASPort2PeerMTUSizeLocalread-onlycurrentf2000EAS Series card Detailed Link OAM Status for Port 2: Peer: MTU Size
1.3.6.1.4.1.4756.20.730.20.1.467Columnf2000EASPort2PeerMultiStateLocalread-onlycurrentf2000EAS Series card Detailed Link OAM Status for Port 2: Peer: Multiplexer State
1.3.6.1.4.1.4756.20.730.20.1.468Columnf2000EASPort2PeerParserStateLocalread-onlycurrentf2000EAS Series card Detailed Link OAM Status for Port 2: Peer: Multiplexer State
1.3.6.1.4.1.4756.20.730.20.1.469Columnf2000EASPort2PeerOUILocalread-onlycurrentf2000EAS Series card Detailed Link OAM Status for Port 2: Peer: Organizational Unique Identification
1.3.6.1.4.1.4756.20.730.20.1.470Columnf2000EASPort2PeerPDURevLocalread-onlycurrentf2000EAS Series card Detailed Link OAM Status for Port 2: Peer: PDU Revision
1.3.6.1.4.1.4756.20.730.20.1.471Columnf2000EASPort3PDUPermisionLocalread-onlycurrentf2000EAS Series card Detailed Link OAM Status for Port 3: PDU Permission
1.3.6.1.4.1.4756.20.730.20.1.472Columnf2000EASPort3DiscoveryStateLocalread-onlycurrentf2000EAS Series card Detailed Link OAM Status for Port 3: Discovery State
1.3.6.1.4.1.4756.20.730.20.1.473Columnf2000EASPort3PeerMACAddrLocalread-onlycurrentf2000EAS Series card Detailed Link OAM Status for Port 3: Discovery State
1.3.6.1.4.1.4756.20.730.20.1.474Columnf2000EASPort3LocalModeLocalread-onlycurrentf2000EAS Series card Detailed Link OAM Status for Port 3: Local: Mode
1.3.6.1.4.1.4756.20.730.20.1.475Columnf2000EASPort3LocalUnOperationLocalread-onlycurrentf2000EAS Series card Detailed Link OAM Status for Port 3: Local: Unidirectional Operation Support
1.3.6.1.4.1.4756.20.730.20.1.476Columnf2000EASPort3LocalRemoteLbLocalread-onlycurrentf2000EAS Series card Detailed Link OAM Status for Port 3: Local: Remote Loopback Support
1.3.6.1.4.1.4756.20.730.20.1.477Columnf2000EASPort3LocalLMLocalread-onlycurrentf2000EAS Series card Detailed Link OAM Status for Port 3: Local: Link Monitoring Support
1.3.6.1.4.1.4756.20.730.20.1.478Columnf2000EASPort3LocalMIBRetrievalLocalread-onlycurrentf2000EAS Series card Detailed Link OAM Status for Port 3: Local: MIB Retrieval Support
1.3.6.1.4.1.4756.20.730.20.1.479Columnf2000EASPort3LocalMTUSizeLocalread-onlycurrentf2000EAS Series card Detailed Link OAM Status for Port 3: Local: MTU Size
1.3.6.1.4.1.4756.20.730.20.1.480Columnf2000EASPort3LocalMultiStateLocalread-onlycurrentf2000EAS Series card Detailed Link OAM Status for Port 3: Local: Multiplexer State
1.3.6.1.4.1.4756.20.730.20.1.481Columnf2000EASPort3LocalParserStateLocalread-onlycurrentf2000EAS Series card Detailed Link OAM Status for Port 3: Local: Multiplexer State
1.3.6.1.4.1.4756.20.730.20.1.482Columnf2000EASPort3LocalOUILocalread-onlycurrentf2000EAS Series card Detailed Link OAM Status for Port 3: Local: Organizational Unique Identification
1.3.6.1.4.1.4756.20.730.20.1.483Columnf2000EASPort3LocalPDURevLocalread-onlycurrentf2000EAS Series card Detailed Link OAM Status for Port 3: Local: PDU Revision
1.3.6.1.4.1.4756.20.730.20.1.484Columnf2000EASPort3PeerModeLocalread-onlycurrentf2000EAS Series card Detailed Link OAM Status for Port 3: Peer: Mode
1.3.6.1.4.1.4756.20.730.20.1.485Columnf2000EASPort3PeerUnOperationLocalread-onlycurrentf2000EAS Series card Detailed Link OAM Status for Port 3: Peer: Unidirectional Operation Support
1.3.6.1.4.1.4756.20.730.20.1.486Columnf2000EASPort3PeerRemoteLbLocalread-onlycurrentf2000EAS Series card Detailed Link OAM Status for Port 3: Peer: Remote Loopback Support
1.3.6.1.4.1.4756.20.730.20.1.487Columnf2000EASPort3PeerLMLocalread-onlycurrentf2000EAS Series card Detailed Link OAM Status for Port 3: Peer: Link Monitoring Support
1.3.6.1.4.1.4756.20.730.20.1.488Columnf2000EASPort3PeerMIBRetrievalLocalread-onlycurrentf2000EAS Series card Detailed Link OAM Status for Port 3: Peer: MIB Retrieval Support
1.3.6.1.4.1.4756.20.730.20.1.489Columnf2000EASPort3PeerMTUSizeLocalread-onlycurrentf2000EAS Series card Detailed Link OAM Status for Port 3: Peer: MTU Size
1.3.6.1.4.1.4756.20.730.20.1.490Columnf2000EASPort3PeerMultiStateLocalread-onlycurrentf2000EAS Series card Detailed Link OAM Status for Port 3: Peer: Multiplexer State
1.3.6.1.4.1.4756.20.730.20.1.491Columnf2000EASPort3PeerParserStateLocalread-onlycurrentf2000EAS Series card Detailed Link OAM Status for Port 3: Peer: Multiplexer State
1.3.6.1.4.1.4756.20.730.20.1.492Columnf2000EASPort3PeerOUILocalread-onlycurrentf2000EAS Series card Detailed Link OAM Status for Port 3: Peer: Organizational Unique Identification
1.3.6.1.4.1.4756.20.730.20.1.493Columnf2000EASPort3PeerPDURevLocalread-onlycurrentf2000EAS Series card Detailed Link OAM Status for Port 3: Peer: PDU Revision
1.3.6.1.4.1.4756.20.730.20.1.494Columnf2000EASPort4PDUPermisionLocalread-onlycurrentf2000EAS Series card Detailed Link OAM Status for Port 4: PDU Permission
1.3.6.1.4.1.4756.20.730.20.1.495Columnf2000EASPort4DiscoveryStateLocalread-onlycurrentf2000EAS Series card Detailed Link OAM Status for Port 4: Discovery State
1.3.6.1.4.1.4756.20.730.20.1.496Columnf2000EASPort4PeerMACAddrLocalread-onlycurrentf2000EAS Series card Detailed Link OAM Status for Port 4: Discovery State
1.3.6.1.4.1.4756.20.730.20.1.497Columnf2000EASPort4LocalModeLocalread-onlycurrentf2000EAS Series card Detailed Link OAM Status for Port 4: Local: Mode
1.3.6.1.4.1.4756.20.730.20.1.498Columnf2000EASPort4LocalUnOperationLocalread-onlycurrentf2000EAS Series card Detailed Link OAM Status for Port 4: Local: Unidirectional Operation Support
1.3.6.1.4.1.4756.20.730.20.1.499Columnf2000EASPort4LocalRemoteLbLocalread-onlycurrentf2000EAS Series card Detailed Link OAM Status for Port 4: Local: Remote Loopback Support
1.3.6.1.4.1.4756.20.730.20.1.500Columnf2000EASPort4LocalLMLocalread-onlycurrentf2000EAS Series card Detailed Link OAM Status for Port 4: Local: Link Monitoring Support
1.3.6.1.4.1.4756.20.730.20.1.501Columnf2000EASPort4LocalMIBRetrievalLocalread-onlycurrentf2000EAS Series card Detailed Link OAM Status for Port 4: Local: MIB Retrieval Support
1.3.6.1.4.1.4756.20.730.20.1.502Columnf2000EASPort4LocalMTUSizeLocalread-onlycurrentf2000EAS Series card Detailed Link OAM Status for Port 4: Local: MTU Size
1.3.6.1.4.1.4756.20.730.20.1.503Columnf2000EASPort4LocalMultiStateLocalread-onlycurrentf2000EAS Series card Detailed Link OAM Status for Port 4: Local: Multiplexer State
1.3.6.1.4.1.4756.20.730.20.1.504Columnf2000EASPort4LocalParserStateLocalread-onlycurrentf2000EAS Series card Detailed Link OAM Status for Port 4: Local: Multiplexer State
1.3.6.1.4.1.4756.20.730.20.1.505Columnf2000EASPort4LocalOUILocalread-onlycurrentf2000EAS Series card Detailed Link OAM Status for Port 4: Local: Organizational Unique Identification
1.3.6.1.4.1.4756.20.730.20.1.506Columnf2000EASPort4LocalPDURevLocalread-onlycurrentf2000EAS Series card Detailed Link OAM Status for Port 4: Local: PDU Revision
1.3.6.1.4.1.4756.20.730.20.1.507Columnf2000EASPort4PeerModeLocalread-onlycurrentf2000EAS Series card Detailed Link OAM Status for Port 4: Peer: Mode
1.3.6.1.4.1.4756.20.730.20.1.508Columnf2000EASPort4PeerUnOperationLocalread-onlycurrentf2000EAS Series card Detailed Link OAM Status for Port 4: Peer: Unidirectional Operation Support
1.3.6.1.4.1.4756.20.730.20.1.509Columnf2000EASPort4PeerRemoteLbLocalread-onlycurrentf2000EAS Series card Detailed Link OAM Status for Port 4: Peer: Remote Loopback Support
1.3.6.1.4.1.4756.20.730.20.1.510Columnf2000EASPort4PeerLMLocalread-onlycurrentf2000EAS Series card Detailed Link OAM Status for Port 4: Peer: Link Monitoring Support
1.3.6.1.4.1.4756.20.730.20.1.511Columnf2000EASPort4PeerMIBRetrievalLocalread-onlycurrentf2000EAS Series card Detailed Link OAM Status for Port 4: Peer: MIB Retrieval Support
1.3.6.1.4.1.4756.20.730.20.1.512Columnf2000EASPort4PeerMTUSizeLocalread-onlycurrentEDD Series card Detailed Link OAM Status for Port 4: Peer: MTU Size
1.3.6.1.4.1.4756.20.730.20.1.513Columnf2000EASPort4PeerMultiStateLocalread-onlycurrentf2000EAS Series card Detailed Link OAM Status for Port 4: Peer: Multiplexer State
1.3.6.1.4.1.4756.20.730.20.1.514Columnf2000EASPort4PeerParserStateLocalread-onlycurrentf2000EAS Series card Detailed Link OAM Status for Port 4: Peer: Multiplexer State
1.3.6.1.4.1.4756.20.730.20.1.515Columnf2000EASPort4PeerOUILocalread-onlycurrentf2000EAS Series card Detailed Link OAM Status for Port 4: Peer: Organizational Unique Identification
1.3.6.1.4.1.4756.20.730.20.1.516Columnf2000EASPort4PeerPDURevLocalread-onlycurrentf2000EAS Series card Detailed Link OAM Status for Port 4: Peer: PDU Revision
1.3.6.1.4.1.4756.20.730.20.1.517Columnf2000EASCLEAROAMCOUNTERLocalread-writecurrentf2000EAS Series card Clear OAM Counter: 0: Off 1: Action
1.3.6.1.4.1.4756.20.730.20.1.518Columnf2000EASLoopProtectionEnableLocalread-writecurrentf2000EAS Series card Loop Protection Configuration: General Settings - Enable Loop Protection 0: Disable 1: Enable
1.3.6.1.4.1.4756.20.730.20.1.519Columnf2000EASLoopProtectionTxTimeLocalread-writecurrentf2000EAS Series card Loop Protection Configuration: General Settings - Transmission Time
1.3.6.1.4.1.4756.20.730.20.1.520Columnf2000EASLoopProtectionShutdownTimeLocalread-writecurrentf2000EAS Series card Loop Protection Configuration: General Settings - Shutdown Time
1.3.6.1.4.1.4756.20.730.20.1.521Columnf2000EASLoopProtectionPort1EnabledLocalread-writecurrentf2000EAS Series card Loop Protection Configuration for Port 1: Port Configuration - Enable 0: Disable 1: Enable
1.3.6.1.4.1.4756.20.730.20.1.522Columnf2000EASLoopProtectionPort1ActionLocalread-writecurrentf2000EAS Series card Loop Protection Configuration for Port 1: Port Configuration - Action 0: Shutdown Port 1: Shutdown Port And Log 2: Log Only
1.3.6.1.4.1.4756.20.730.20.1.523Columnf2000EASLoopProtectionPort1TxModeLocalread-writecurrentf2000EAS Series card Loop Protection Configuration for Port 1: Port Configuration - Tx Mode 0: Disable 1: Enable
1.3.6.1.4.1.4756.20.730.20.1.524Columnf2000EASLoopProtectionPort2EnabledLocalread-writecurrentf2000EAS Series card Loop Protection Configuration for Port 2: Port Configuration - Enable 0: Disable 1: Enable
1.3.6.1.4.1.4756.20.730.20.1.525Columnf2000EASLoopProtectionPort2ActionLocalread-writecurrentf2000EAS Series card Loop Protection Configuration for Port 2: Port Configuration - Action 0: Shutdown Port 1: Shutdown Port And Log 2: Log Only
1.3.6.1.4.1.4756.20.730.20.1.526Columnf2000EASLoopProtectionPort2TxModeLocalread-writecurrentf2000EAS Series card Loop Protection Configuration for Port 2: Port Configuration - Tx Mode 0: Disable 1: Enable
1.3.6.1.4.1.4756.20.730.20.1.527Columnf2000EASLoopProtectionPort3EnabledLocalread-writecurrentf2000EASE Series card Loop Protection Configuration for Port 3: Port Configuration - Enable 0: Disable 1: Enable
1.3.6.1.4.1.4756.20.730.20.1.528Columnf2000EASLoopProtectionPort3ActionLocalread-writecurrentf2000EAS Series card Loop Protection Configuration for Port 3: Port Configuration - Action 0: Shutdown Port 1: Shutdown Port And Log 2: Log Only
1.3.6.1.4.1.4756.20.730.20.1.529Columnf2000EASLoopProtectionPort3TxModeLocalread-writecurrentf2000EAS Series card Loop Protection Configuration for Port 3: Port Configuration - Tx Mode 0: Disable 1: Enable
1.3.6.1.4.1.4756.20.730.20.1.530Columnf2000EASLoopProtectionPort4EnabledLocalread-writecurrentf2000EAS Series card Loop Protection Configuration for Port 4: Port Configuration - Enable 0: Disable 1: Enable
1.3.6.1.4.1.4756.20.730.20.1.531Columnf2000EASLoopProtectionPort4ActionLocalread-writecurrentf2000EAS Series card Loop Protection Configuration for Port 4: Port Configuration - Action 0: Shutdown Port 1: Shutdown Port And Log 2: Log Only
1.3.6.1.4.1.4756.20.730.20.1.532Columnf2000EASLoopProtectionPort4TxModeLocalread-writecurrentf2000EAS Series card Loop Protection Configuration for Port 41: Port Configuration - Tx Mode 0: Disable 1: Enable
1.3.6.1.4.1.4756.20.730.20.1.533Columnf2000EASLoopProtectionPort1ActionStsLocalread-onlycurrentf2000EAS Series card Loop Protection Status for Port 1: Action
1.3.6.1.4.1.4756.20.730.20.1.534Columnf2000EASLoopProtectionPort1TransStsLocalread-onlycurrentf2000EAS Series card Loop Protection Status for Port 1: Transmit
1.3.6.1.4.1.4756.20.730.20.1.535Columnf2000EASLoopProtectionPort1LoopsStsLocalread-onlycurrentf2000EAS Series card Loop Protection Status for Port 1: Loops
1.3.6.1.4.1.4756.20.730.20.1.536Columnf2000EASLoopProtectionPort1StatusLocalread-onlycurrentf2000EAS Series card Loop Protection Status for Port 1: Status
1.3.6.1.4.1.4756.20.730.20.1.537Columnf2000EASLoopProtectionPort1LoopStsLocalread-onlycurrentf2000EAS Series card Loop Protection Status for Port 1: Loop
1.3.6.1.4.1.4756.20.730.20.1.538Columnf2000EASLoopProtectionPort2ActionStsLocalread-onlycurrentf2000EAS Series card Loop Protection Status for Port 2: Action
1.3.6.1.4.1.4756.20.730.20.1.539Columnf2000EASLoopProtectionPort2TransStsLocalread-onlycurrentf2000EAS Series card Loop Protection Status for Port 2: Transmit
1.3.6.1.4.1.4756.20.730.20.1.540Columnf2000EASLoopProtectionPort2LoopsStsLocalread-onlycurrentf2000EAS Series card Loop Protection Status for Port 2: Loops
1.3.6.1.4.1.4756.20.730.20.1.541Columnf2000EASLoopProtectionPort2StatusLocalread-onlycurrentf2000EAS Series card Loop Protection Status for Port 2: Status
1.3.6.1.4.1.4756.20.730.20.1.542Columnf2000EASLoopProtectionPort2LoopStsLocalread-onlycurrentf2000EAS Series card Loop Protection Status for Port 2: Loop
1.3.6.1.4.1.4756.20.730.20.1.543Columnf2000EASLoopProtectionPort3ActionStsLocalread-onlycurrentf2000EAS Series card Loop Protection Status for Port 3: Action
1.3.6.1.4.1.4756.20.730.20.1.544Columnf2000EASLoopProtectionPort3TransStsLocalread-onlycurrentf2000EAS Series card Loop Protection Status for Port 3: Transmit
1.3.6.1.4.1.4756.20.730.20.1.545Columnf2000EASLoopProtectionPort3LoopsStsLocalread-onlycurrentf2000EAS Series card Loop Protection Status for Port 3: Loops
1.3.6.1.4.1.4756.20.730.20.1.546Columnf2000EASLoopProtectionPort3StatusLocalread-onlycurrentf2000EAS Series card Loop Protection Status for Port 3: Status
1.3.6.1.4.1.4756.20.730.20.1.547Columnf2000EASLoopProtectionPort3LoopStsLocalread-onlycurrentf2000EAS Series card Loop Protection Status for Port 3: Loop
1.3.6.1.4.1.4756.20.730.20.1.548Columnf2000EASLoopProtectionPort4ActionStsLocalread-onlycurrentf2000EAS Series card Loop Protection Status for Port 4: Action
1.3.6.1.4.1.4756.20.730.20.1.549Columnf2000EASLoopProtectionPort4TransStsLocalread-onlycurrentf2000EAS Series card Loop Protection Status for Port 4: Transmit
1.3.6.1.4.1.4756.20.730.20.1.550Columnf2000EASLoopProtectionPort4LoopsStsLocalread-onlycurrentf2000EAS Series card Loop Protection Status for Port 4: Loops
1.3.6.1.4.1.4756.20.730.20.1.551Columnf2000EASLoopProtectionPort4StatusLocalread-onlycurrentf2000EAS Series card Loop Protection Status for Port 4: Status
1.3.6.1.4.1.4756.20.730.20.1.552Columnf2000EASLoopProtectionPort4LoopStsLocalread-onlycurrentf2000EAS Series card Loop Protection Status for Port 4: Loop
1.3.6.1.4.1.4756.20.730.20.1.553Columnf2000EASSTPProtocolVersionLocalread-writecurrentf2000EAS Series card STP Bridge Configuration: Basic Settings - Protocol Version 0: STP 1: RSTP 2: MSTP
1.3.6.1.4.1.4756.20.730.20.1.554Columnf2000EASSTPBridgePriorityLocalread-writecurrentf2000EAS Series card STP Bridge Configuration: Basic Settings - Bridge Priority 0: 0 1: 4096 2: 8192 3: 12288 4: 16384 5: 20480 6: 24576 7: 28672 8: 32768 9: 3…
1.3.6.1.4.1.4756.20.730.20.1.555Columnf2000EASSTPForwardDelayLocalread-writecurrentf2000EAS Series card STP Bridge Configuration: Basic Settings - Forward Delay
1.3.6.1.4.1.4756.20.730.20.1.556Columnf2000EASSTPMaxAgeLocalread-writecurrentf2000EAS Series card STP Bridge Configuration: Basic Settings - Max Age
1.3.6.1.4.1.4756.20.730.20.1.557Columnf2000EASSTPMaximumHopCountLocalread-writecurrentf2000EAS Series card STP Bridge Configuration: Basic Settings - Maximum Hop Count
1.3.6.1.4.1.4756.20.730.20.1.558Columnf2000EASSTPTransmitHoldCountLocalread-writecurrentf2000EAS Series card STP Bridge Configuration: Basic Settings - Transmit Hold Count
1.3.6.1.4.1.4756.20.730.20.1.559Columnf2000EASSTPEdgePortBPDUFilteringLocalread-writecurrentf2000EAS Series card STP Bridge Configuration: Advanced Settings - Edge Port BPDU Filtering 0: Off 1: On
1.3.6.1.4.1.4756.20.730.20.1.560Columnf2000EASSTPEdgePortBPDUGuardLocalread-writecurrentf2000EAS Series card STP Bridge Configuration: Advanced Settings - Edge Port BPDU Guard 0: Off 1: On
1.3.6.1.4.1.4756.20.730.20.1.561Columnf2000EASSTPPortErrorRecoveryTimeoutLocalread-writecurrentf2000EAS Series card STP Bridge Configuration: Advanced Settings - Port Error Recovery Timeout 0: Off 1: On
1.3.6.1.4.1.4756.20.730.20.1.562Columnf2000EASMSTIConfigurationNameLocalread-writecurrentf2000EAS Series card MSTI Configuration: Configuration Identification - Configuration Name
1.3.6.1.4.1.4756.20.730.20.1.563Columnf2000EASMSTIConfigurationRevisionLocalread-writecurrentf2000EAS Series card MSTI Configuration: Configuration Identification - Configuration Revision
1.3.6.1.4.1.4756.20.730.20.1.564Columnf2000EASMSTI1VLANsMappingLocalread-writecurrentf2000EAS Series card MSTI Configuration: MSTI Mapping - MSTI 1
1.3.6.1.4.1.4756.20.730.20.1.565Columnf2000EASMSTI2VLANsMappingLocalread-writecurrentf2000EAS Series card MSTI Configuration: MSTI Mapping - MSTI 2
1.3.6.1.4.1.4756.20.730.20.1.566Columnf2000EASMSTI3VLANsMappingLocalread-writecurrentf2000EAS Series card MSTI Configuration: MSTI Mapping - MSTI 3
1.3.6.1.4.1.4756.20.730.20.1.567Columnf2000EASMSTI4VLANsMappingLocalread-writecurrentf2000EAS Series card MSTI Configuration: MSTI Mapping - MSTI 4
1.3.6.1.4.1.4756.20.730.20.1.568Columnf2000EASMSTI5VLANsMappingLocalread-writecurrentf2000EAS Series card MSTI Configuration: MSTI Mapping - MSTI 5
1.3.6.1.4.1.4756.20.730.20.1.569Columnf2000EASMSTI6VLANsMappingLocalread-writecurrentf2000EAS Series card MSTI Configuration: MSTI Mapping - MSTI 6
1.3.6.1.4.1.4756.20.730.20.1.570Columnf2000EASMSTI7VLANsMappingLocalread-writecurrentf2000EAS Series card MSTI Configuration: MSTI Mapping - MSTI 7
1.3.6.1.4.1.4756.20.730.20.1.571Columnf2000EASCISTAggregatedSTPEnabledLocalread-writecurrentf2000EAS Series card STP CIST Port Configuration: CIST Aggregated Port Configuration - STP Enabled
1.3.6.1.4.1.4756.20.730.20.1.572Columnf2000EASCISTAggregatedPathCostLocalread-writecurrentf2000EAS Series card STP CIST Port Configuration: CIST Aggregated Port Configuration - Path Cost Valid values are in the range 0 to 200000000. Setting 0 means …
1.3.6.1.4.1.4756.20.730.20.1.573Columnf2000EASCISTAggregatedPriorityLocalread-writecurrentf2000EAS Series card STP CIST Port Configuration: CIST Aggregated Port Configuration - Priority
1.3.6.1.4.1.4756.20.730.20.1.574Columnf2000EASCISTAggregatedAdminEdgeLocalread-writecurrentf2000EAS Series card STP CIST Port Configuration: CIST Aggregated Port Configuration - STP Enabled 0: Non-edge 1: Edge
1.3.6.1.4.1.4756.20.730.20.1.575Columnf2000EASCISTAggregatedAutoEdgeLocalread-writecurrentf2000EAS Series card STP CIST Port Configuration: CIST Aggregated Port Configuration - Auto Edge 0: Non-edge 1: Edge
1.3.6.1.4.1.4756.20.730.20.1.576Columnf2000EASCISTAggregatedRestrictedRoleLocalread-writecurrentf2000EAS Series card STP CIST Port Configuration: CIST Aggregated Port Configuration - Restricted Role 0: Non-edge 1: Edge
1.3.6.1.4.1.4756.20.730.20.1.577Columnf2000EASCISTAggregatedRestrictedTCNLocalread-writecurrentf2000EAS Series card STP CIST Port Configuration: CIST Aggregated Port Configuration - Restricted TCN 0: Non-edge 1: Edge
1.3.6.1.4.1.4756.20.730.20.1.578Columnf2000EASCISTAggregatedBPDUGuardLocalread-writecurrentf2000EAS Series card STP CIST Port Configuration: CIST Aggregated Port Configuration - BPDU Guard 0: Non-edge 1: Edge
1.3.6.1.4.1.4756.20.730.20.1.579Columnf2000EASCISTAggregatedPointToPointLocalread-writecurrentf2000EAS Series card STP CIST Port Configuration: CIST Aggregated Port Configuration - Point-to-point 0: Forced True 1: Forced False 2: Auto
1.3.6.1.4.1.4756.20.730.20.1.580Columnf2000EASCISTPort1STPEnabledLocalread-writecurrentf2000EAS Series card STP CIST Port Configuration: CIST Normal Port1 Configuration - STP Enabled
1.3.6.1.4.1.4756.20.730.20.1.581Columnf2000EASCISTPort1PathCostLocalread-writecurrentf2000EAS Series card STP CIST Port Configuration: CIST Normal Port1 Configuration - Path Cost Valid values are in the range 0 to 200000000. Setting 0 means Aut…
1.3.6.1.4.1.4756.20.730.20.1.582Columnf2000EASCISTPort1PriorityLocalread-writecurrentf2000EAS Series card STP CIST Port Configuration: CIST Normal Port1 Configuration - Priority
1.3.6.1.4.1.4756.20.730.20.1.583Columnf2000EASCISTPort1AdminEdgeLocalread-writecurrentf2000EAS Series card STP CIST Port Configuration: CIST Normal Port1 Configuration - STP Enabled 0: Non-edge 1: Edge
1.3.6.1.4.1.4756.20.730.20.1.584Columnf2000EASCISTPort1AutoEdgeLocalread-writecurrentf2000EAS Series card STP CIST Port Configuration: CIST Normal Port1 Configuration - Auto Edge 0: Non-edge 1: Edge
1.3.6.1.4.1.4756.20.730.20.1.585Columnf2000EASCISTPort1RestrictedRoleLocalread-writecurrentf2000EAS Series card STP CIST Port Configuration: CIST Normal Port1 Configuration - Restricted Role 0: Non-edge 1: Edge
1.3.6.1.4.1.4756.20.730.20.1.586Columnf2000EASCISTPort1RestrictedTCNLocalread-writecurrentf2000EAS Series card STP CIST Port Configuration: CIST Normal Port1 Configuration - Restricted TCN 0: Non-edge 1: Edge
1.3.6.1.4.1.4756.20.730.20.1.587Columnf2000EASCISTPort1BPDUGuardLocalread-writecurrentf2000EAS Series card STP CIST Port Configuration: CIST Normal Port1 Configuration - BPDU Guard 0: Non-edge 1: Edge
1.3.6.1.4.1.4756.20.730.20.1.588Columnf2000EASCISTPort1PointToPointLocalread-writecurrentf2000EAS Series card STP CIST Port Configuration: CIST Normal Port1 Configuration - Point-to-point 0: Forced True 1: Forced False 2: Auto
1.3.6.1.4.1.4756.20.730.20.1.589Columnf2000EASCISTPort2STPEnabledLocalread-writecurrentf2000EAS Series card STP CIST Port Configuration: CIST Normal Port2 Configuration - STP Enabled
1.3.6.1.4.1.4756.20.730.20.1.590Columnf2000EASCISTPort2PathCostLocalread-writecurrentf2000EAS Series card STP CIST Port Configuration: CIST Normal Port2 Configuration - Path Cost Valid values are in the range 0 to 200000000. Setting 0 means Aut…
1.3.6.1.4.1.4756.20.730.20.1.591Columnf2000EASCISTPort2PriorityLocalread-writecurrentf2000EAS Series card STP CIST Port Configuration: CIST Normal Port2 Configuration - Priority
1.3.6.1.4.1.4756.20.730.20.1.592Columnf2000EASCISTPort2AdminEdgeLocalread-writecurrentf2000EAS Series card STP CIST Port Configuration: CIST Normal Port2 Configuration - STP Enabled 0: Non-edge 1: Edge
1.3.6.1.4.1.4756.20.730.20.1.593Columnf2000EASCISTPort2AutoEdgeLocalread-writecurrentf2000EAS Series card STP CIST Port Configuration: CIST Normal Port2 Configuration - Auto Edge 0: Non-edge 1: Edge
1.3.6.1.4.1.4756.20.730.20.1.594Columnf2000EASCISTPort2RestrictedRoleLocalread-writecurrentf2000EAS Series card STP CIST Port Configuration: CIST Normal Port2 Configuration - Restricted Role 0: Non-edge 1: Edge
1.3.6.1.4.1.4756.20.730.20.1.595Columnf2000EASCISTPort2RestrictedTCNLocalread-writecurrentf2000EAS Series card STP CIST Port Configuration: CIST Normal Port2 Configuration - Restricted TCN 0: Non-edge 1: Edge
1.3.6.1.4.1.4756.20.730.20.1.596Columnf2000EASCISTPort2BPDUGuardLocalread-writecurrentf2000EAS Series card STP CIST Port Configuration: CIST Normal Port2 Configuration - BPDU Guard 0: Non-edge 1: Edge
1.3.6.1.4.1.4756.20.730.20.1.597Columnf2000EASCISTPort2PointToPointLocalread-writecurrentf2000EAS Series card STP CIST Port Configuration: CIST Normal Port2 Configuration - Point-to-point 0: Forced True 1: Forced False 2: Auto
1.3.6.1.4.1.4756.20.730.20.1.598Columnf2000EASCISTPort3STPEnabledLocalread-writecurrentf2000EAS Series card STP CIST Port Configuration: CIST Normal Port3 Configuration - STP Enabled
1.3.6.1.4.1.4756.20.730.20.1.599Columnf2000EASCISTPort3PathCostLocalread-writecurrentf2000EAS Series card STP CIST Port Configuration: CIST Normal Port3 Configuration - Path Cost Valid values are in the range 0 to 200000000. Setting 0 means Aut…
1.3.6.1.4.1.4756.20.730.20.1.600Columnf2000EASCISTPort3PriorityLocalread-writecurrentf2000EAS Series card STP CIST Port Configuration: CIST Normal Port3 Configuration - Priority
1.3.6.1.4.1.4756.20.730.20.1.601Columnf2000EASCISTPort3AdminEdgeLocalread-writecurrentf2000EAS Series card STP CIST Port Configuration: CIST Normal Port3 Configuration - STP Enabled 0: Non-edge 1: Edge
1.3.6.1.4.1.4756.20.730.20.1.602Columnf2000EASCISTPort3AutoEdgeLocalread-writecurrentf2000EAS Series card STP CIST Port Configuration: CIST Normal Port3 Configuration - Auto Edge 0: Non-edge 1: Edge
1.3.6.1.4.1.4756.20.730.20.1.603Columnf2000EASCISTPort3RestrictedRoleLocalread-writecurrentf2000EAS Series card STP CIST Port Configuration: CIST Normal Port3 Configuration - Restricted Role 0: Non-edge 1: Edge
1.3.6.1.4.1.4756.20.730.20.1.604Columnf2000EASCISTPort3RestrictedTCNLocalread-writecurrentf2000EAS Series card STP CIST Port Configuration: CIST Normal Port3 Configuration - Restricted TCN 0: Non-edge 1: Edge
1.3.6.1.4.1.4756.20.730.20.1.605Columnf2000EASCISTPort3BPDUGuardLocalread-writecurrentf2000EAS Series card STP CIST Port Configuration: CIST Normal Port3 Configuration - BPDU Guard 0: Non-edge 1: Edge
1.3.6.1.4.1.4756.20.730.20.1.606Columnf2000EASCISTPort3PointToPointLocalread-writecurrentf2000EAS Series card STP CIST Port Configuration: CIST Normal Port3 Configuration - Point-to-point 0: Forced True 1: Forced False 2: Auto
1.3.6.1.4.1.4756.20.730.20.1.607Columnf2000EASCISTPort4STPEnabledLocalread-writecurrentf2000EAS Series card STP CIST Port Configuration: CIST Normal Port4 Configuration - STP Enabled
1.3.6.1.4.1.4756.20.730.20.1.608Columnf2000EASCISTPort4PathCostLocalread-writecurrentf2000EAS Series card STP CIST Port Configuration: CIST Normal Port4 Configuration - Path Cost Valid values are in the range 0 to 200000000. Setting 0 means Aut…
1.3.6.1.4.1.4756.20.730.20.1.609Columnf2000EASCISTPort4PriorityLocalread-writecurrentf2000EAS Series card STP CIST Port Configuration: CIST Normal Port4 Configuration - Priority
1.3.6.1.4.1.4756.20.730.20.1.610Columnf2000EASCISTPort4AdminEdgeLocalread-writecurrentf2000EAS Series card STP CIST Port Configuration: CIST Normal Port4 Configuration - STP Enabled 0: Non-edge 1: Edge
1.3.6.1.4.1.4756.20.730.20.1.611Columnf2000EASCISTPort4AutoEdgeLocalread-writecurrentf2000EAS Series card STP CIST Port Configuration: CIST Normal Port4 Configuration - Auto Edge 0: Non-edge 1: Edge
1.3.6.1.4.1.4756.20.730.20.1.612Columnf2000EASCISTPort4RestrictedRoleLocalread-writecurrentf2000EAS Series card STP CIST Port Configuration: CIST Normal Port4 Configuration - Restricted Role 0: Non-edge 1: Edge
1.3.6.1.4.1.4756.20.730.20.1.613Columnf2000EASCISTPort4RestrictedTCNLocalread-writecurrentf2000EAS Series card STP CIST Port Configuration: CIST Normal Port4 Configuration - Restricted TCN 0: Non-edge 1: Edge
1.3.6.1.4.1.4756.20.730.20.1.614Columnf2000EASCISTPort4BPDUGuardLocalread-writecurrentf2000EAS Series card STP CIST Port Configuration: CIST Normal Port4 Configuration - BPDU Guard 0: Non-edge 1: Edge
1.3.6.1.4.1.4756.20.730.20.1.615Columnf2000EASCISTPort4PointToPointLocalread-writecurrentf2000EAS Series card STP CIST Port Configuration: CIST Normal Port4 Configuration - Point-to-point 0: Forced True 1: Forced False 2: Auto
1.3.6.1.4.1.4756.20.730.20.1.616Columnf2000EASMSTI1AggregatedPathCostLocalread-writecurrentf2000EAS Series card MSTI Port Configuration: MSTI1 Aggregated Ports Configuration - Path Cost Valid values are in the range 0 to 200000000. Setting 0 means Au…
1.3.6.1.4.1.4756.20.730.20.1.617Columnf2000EASMSTI1AggregatedPriorityLocalread-writecurrentf2000EAS Series card MSTI Port Configuration: MSTI1 Aggregated Ports Configuration - Priority
1.3.6.1.4.1.4756.20.730.20.1.618Columnf2000EASMSTI1Port1PathCostLocalread-writecurrentf2000EAS Series card MSTI Port Configuration: MSTI1 Normal Port1 Configuration - Path Cost Valid values are in the range 0 to 200000000. Setting 0 means Auto p…
1.3.6.1.4.1.4756.20.730.20.1.619Columnf2000EASMSTI1Port1PriorityLocalread-writecurrentf2000EAS Series card MSTI Port Configuration: MSTI1 Normal Port1 Configuration - Priority
1.3.6.1.4.1.4756.20.730.20.1.620Columnf2000EASMSTI1Port2PathCostLocalread-writecurrentf2000EAS Series card MSTI Port Configuration: MSTI1 Normal Port2 Configuration - Path Cost Valid values are in the range 0 to 200000000. Setting 0 means Auto p…
1.3.6.1.4.1.4756.20.730.20.1.621Columnf2000EASMSTI1Port2PriorityLocalread-writecurrentf2000EAS Series card MSTI Port Configuration: MSTI1 Normal Port2 Configuration - Priority
1.3.6.1.4.1.4756.20.730.20.1.622Columnf2000EASMSTI1Port3PathCostLocalread-writecurrentf2000EAS Series card MSTI Port Configuration: MSTI1 Normal Port3 Configuration - Path Cost Valid values are in the range 0 to 200000000. Setting 0 means Auto p…
1.3.6.1.4.1.4756.20.730.20.1.623Columnf2000EASMSTI1Port3PriorityLocalread-writecurrentf2000EAS Series card MSTI Port Configuration: MSTI1 Normal Port3 Configuration - Priority
1.3.6.1.4.1.4756.20.730.20.1.624Columnf2000EASMSTI1Port4PathCostLocalread-writecurrentf2000EAS Series card MSTI Port Configuration: MSTI1 Normal Port4 Configuration - Path Cost Valid values are in the range 0 to 200000000. Setting 0 means Auto p…
1.3.6.1.4.1.4756.20.730.20.1.625Columnf2000EASMSTI1Port4PriorityLocalread-writecurrentf2000EAS Series card MSTI Port Configuration: MSTI1 Normal Port4 Configuration - Priority
1.3.6.1.4.1.4756.20.730.20.1.626Columnf2000EASMSTI2AggregatedPathCostLocalread-writecurrentf2000EAS Series card MSTI Port Configuration: MSTI2 Aggregated Ports Configuration - Path Cost Valid values are in the range 0 to 200000000. Setting 0 means Au…
1.3.6.1.4.1.4756.20.730.20.1.627Columnf2000EASMSTI2AggregatedPriorityLocalread-writecurrentf2000EAS Series card MSTI Port Configuration: MSTI2 Aggregated Ports Configuration - Priority
1.3.6.1.4.1.4756.20.730.20.1.628Columnf2000EASMSTI2Port1PathCostLocalread-writecurrentf2000EAS Series card MSTI Port Configuration: MSTI2 Normal Port1 Configuration - Path Cost Valid values are in the range 0 to 200000000. Setting 0 means Auto p…
1.3.6.1.4.1.4756.20.730.20.1.629Columnf2000EASMSTI2Port1PriorityLocalread-writecurrentf2000EAS Series card MSTI Port Configuration: MSTI2 Normal Port1 Configuration - Priority
1.3.6.1.4.1.4756.20.730.20.1.630Columnf2000EASMSTI2Port2PathCostLocalread-writecurrentf2000EAS Series card MSTI Port Configuration: MSTI2 Normal Port2 Configuration - Path Cost Valid values are in the range 0 to 200000000. Setting 0 means Auto p…
1.3.6.1.4.1.4756.20.730.20.1.631Columnf2000EASMSTI2Port2PriorityLocalread-writecurrentf2000EAS Series card MSTI Port Configuration: MSTI2 Normal Port2 Configuration - Priority
1.3.6.1.4.1.4756.20.730.20.1.632Columnf2000EASMSTI2Port3PathCostLocalread-writecurrentf2000EAS Series card MSTI Port Configuration: MSTI2 Normal Port3 Configuration - Path Cost Valid values are in the range 0 to 200000000. Setting 0 means Auto p…
1.3.6.1.4.1.4756.20.730.20.1.633Columnf2000EASMSTI2Port3PriorityLocalread-writecurrentf2000EAS Series card MSTI Port Configuration: MSTI2 Normal Port3 Configuration - Priority
1.3.6.1.4.1.4756.20.730.20.1.634Columnf2000EASMSTI2Port4PathCostLocalread-writecurrentf2000EAS Series card MSTI Port Configuration: MSTI2 Normal Port4 Configuration - Path Cost Valid values are in the range 0 to 200000000. Setting 0 means Auto p…
1.3.6.1.4.1.4756.20.730.20.1.635Columnf2000EASMSTI2Port4PriorityLocalread-writecurrentf2000EAS Series card MSTI Port Configuration: MSTI2 Normal Port4 Configuration - Priority
1.3.6.1.4.1.4756.20.730.20.1.636Columnf2000EASMSTI3AggregatedPathCostLocalread-writecurrentf2000EAS Series card MSTI Port Configuration: MSTI3 Aggregated Ports Configuration - Path Cost Valid values are in the range 0 to 200000000. Setting 0 means Au…
1.3.6.1.4.1.4756.20.730.20.1.637Columnf2000EASMSTI3AggregatedPriorityLocalread-writecurrentf2000EAS Series card MSTI Port Configuration: MSTI3 Aggregated Ports Configuration - Priority
1.3.6.1.4.1.4756.20.730.20.1.638Columnf2000EASMSTI3Port1PathCostLocalread-writecurrentf2000EAS Series card MSTI Port Configuration: MSTI3 Normal Port1 Configuration - Path Cost Valid values are in the range 0 to 200000000. Setting 0 means Auto p…
1.3.6.1.4.1.4756.20.730.20.1.639Columnf2000EASMSTI3Port1PriorityLocalread-writecurrentf2000EAS Series card MSTI Port Configuration: MSTI3 Normal Port1 Configuration - Priority
1.3.6.1.4.1.4756.20.730.20.1.640Columnf2000EASMSTI3Port2PathCostLocalread-writecurrentf2000EAS Series card MSTI Port Configuration: MSTI3 Normal Port2 Configuration - Path Cost Valid values are in the range 0 to 200000000. Setting 0 means Auto p…
1.3.6.1.4.1.4756.20.730.20.1.641Columnf2000EASMSTI3Port2PriorityLocalread-writecurrentf2000EAS Series card MSTI Port Configuration: MSTI3 Normal Port2 Configuration - Priority
1.3.6.1.4.1.4756.20.730.20.1.642Columnf2000EASMSTI3Port3PathCostLocalread-writecurrentf2000EAS Series card MSTI Port Configuration: MSTI1 Normal Port3 Configuration - Path Cost Valid values are in the range 0 to 200000000. Setting 0 means Auto p…
1.3.6.1.4.1.4756.20.730.20.1.643Columnf2000EASMSTI3Port3PriorityLocalread-writecurrentf2000EAS Series card MSTI Port Configuration: MSTI3 Normal Port3 Configuration - Priority
1.3.6.1.4.1.4756.20.730.20.1.644Columnf2000EASMSTI3Port4PathCostLocalread-writecurrentf2000EAS Series card MSTI Port Configuration: MSTI3 Normal Port4 Configuration - Path Cost Valid values are in the range 0 to 200000000. Setting 0 means Auto p…
1.3.6.1.4.1.4756.20.730.20.1.645Columnf2000EASMSTI3Port4PriorityLocalread-writecurrentf2000EAS Series card MSTI Port Configuration: MSTI3 Normal Port4 Configuration - Priority
1.3.6.1.4.1.4756.20.730.20.1.646Columnf2000EASMSTI4AggregatedPathCostLocalread-writecurrentf2000EAS Series card MSTI Port Configuration: MSTI4 Aggregated Ports Configuration - Path Cost Valid values are in the range 0 to 200000000. Setting 0 means Au…
1.3.6.1.4.1.4756.20.730.20.1.647Columnf2000EASMSTI4AggregatedPriorityLocalread-writecurrentf2000EAS Series card MSTI Port Configuration: MSTI4 Aggregated Ports Configuration - Priority
1.3.6.1.4.1.4756.20.730.20.1.648Columnf2000EASMSTI4Port1PathCostLocalread-writecurrentf2000EAS Series card MSTI Port Configuration: MSTI4 Normal Port1 Configuration - Path Cost Valid values are in the range 0 to 200000000. Setting 0 means Auto p…
1.3.6.1.4.1.4756.20.730.20.1.649Columnf2000EASMSTI4Port1PriorityLocalread-writecurrentf2000EAS Series card MSTI Port Configuration: MSTI4 Normal Port1 Configuration - Priority
1.3.6.1.4.1.4756.20.730.20.1.650Columnf2000EASMSTI4Port2PathCostLocalread-writecurrentf2000EAS Series card MSTI Port Configuration: MSTI4 Normal Port2 Configuration - Path Cost Valid values are in the range 0 to 200000000. Setting 0 means Auto p…
1.3.6.1.4.1.4756.20.730.20.1.651Columnf2000EASMSTI4Port2PriorityLocalread-writecurrentf2000EAS Series card MSTI Port Configuration: MSTI4 Normal Port2 Configuration - Priority
1.3.6.1.4.1.4756.20.730.20.1.652Columnf2000EASMSTI4Port3PathCostLocalread-writecurrentf2000EAS Series card MSTI Port Configuration: MSTI1 Normal Port3 Configuration - Path Cost Valid values are in the range 0 to 200000000. Setting 0 means Auto p…
1.3.6.1.4.1.4756.20.730.20.1.653Columnf2000EASMSTI4Port3PriorityLocalread-writecurrentf2000EAS Series card MSTI Port Configuration: MSTI4 Normal Port3 Configuration - Priority
1.3.6.1.4.1.4756.20.730.20.1.654Columnf2000EASMSTI4Port4PathCostLocalread-writecurrentf2000EAS Series card MSTI Port Configuration: MSTI4 Normal Port4 Configuration - Path Cost Valid values are in the range 0 to 200000000. Setting 0 means Auto p…
1.3.6.1.4.1.4756.20.730.20.1.655Columnf2000EASMSTI4Port4PriorityLocalread-writecurrentf2000EAS Series card MSTI Port Configuration: MSTI4 Normal Port4 Configuration - Priority
1.3.6.1.4.1.4756.20.730.20.1.656Columnf2000EASMSTI5AggregatedPathCostLocalread-writecurrentf2000EAS Series card MSTI Port Configuration: MSTI5 Aggregated Ports Configuration - Path Cost Valid values are in the range 0 to 200000000. Setting 0 means Au…
1.3.6.1.4.1.4756.20.730.20.1.657Columnf2000EASMSTI5AggregatedPriorityLocalread-writecurrentf2000EAS Series card MSTI Port Configuration: MSTI5 Aggregated Ports Configuration - Priority
1.3.6.1.4.1.4756.20.730.20.1.658Columnf2000EASMSTI5Port1PathCostLocalread-writecurrentf2000EAS Series card MSTI Port Configuration: MSTI5 Normal Port1 Configuration - Path Cost Valid values are in the range 0 to 200000000. Setting 0 means Auto p…
1.3.6.1.4.1.4756.20.730.20.1.659Columnf2000EASMSTI5Port1PriorityLocalread-writecurrentf2000EAS Series card MSTI Port Configuration: MSTI5 Normal Port1 Configuration - Priority
1.3.6.1.4.1.4756.20.730.20.1.660Columnf2000EASMSTI5Port2PathCostLocalread-writecurrentf2000EAS Series card MSTI Port Configuration: MSTI5 Normal Port2 Configuration - Path Cost Valid values are in the range 0 to 200000000. Setting 0 means Auto p…
1.3.6.1.4.1.4756.20.730.20.1.661Columnf2000EASMSTI5Port2PriorityLocalread-writecurrentf2000EAS Series card MSTI Port Configuration: MSTI5 Normal Port2 Configuration - Priority
1.3.6.1.4.1.4756.20.730.20.1.662Columnf2000EASMSTI5Port3PathCostLocalread-writecurrentf2000EAS Series card MSTI Port Configuration: MSTI5 Normal Port3 Configuration - Path Cost Valid values are in the range 0 to 200000000. Setting 0 means Auto p…
1.3.6.1.4.1.4756.20.730.20.1.663Columnf2000EASMSTI5Port3PriorityLocalread-writecurrentf2000EAS Series card MSTI Port Configuration: MSTI5 Normal Port3 Configuration - Priority
1.3.6.1.4.1.4756.20.730.20.1.664Columnf2000EASMSTI5Port4PathCostLocalread-writecurrentf2000EAS Series card MSTI Port Configuration: MSTI5 Normal Port4 Configuration - Path Cost Valid values are in the range 0 to 200000000. Setting 0 means Auto p…
1.3.6.1.4.1.4756.20.730.20.1.665Columnf2000EASMSTI5Port4PriorityLocalread-writecurrentf2000EAS Series card MSTI Port Configuration: MSTI5 Normal Port4 Configuration - Priority
1.3.6.1.4.1.4756.20.730.20.1.666Columnf2000EASMSTI6AggregatedPathCostLocalread-writecurrentf2000EAS Series card MSTI Port Configuration: MSTI6 Aggregated Ports Configuration - Path Cost Valid values are in the range 0 to 200000000. Setting 0 means Au…
1.3.6.1.4.1.4756.20.730.20.1.667Columnf2000EASMSTI6AggregatedPriorityLocalread-writecurrentf2000EAS Series card MSTI Port Configuration: MSTI6 Aggregated Ports Configuration - Priority
1.3.6.1.4.1.4756.20.730.20.1.668Columnf2000EASMSTI6Port1PathCostLocalread-writecurrentf2000EAS Series card MSTI Port Configuration: MSTI6 Normal Port1 Configuration - Path Cost Valid values are in the range 0 to 200000000. Setting 0 means Auto p…
1.3.6.1.4.1.4756.20.730.20.1.669Columnf2000EASMSTI6Port1PriorityLocalread-writecurrentf2000EAS Series card MSTI Port Configuration: MSTI6 Normal Port1 Configuration - Priority
1.3.6.1.4.1.4756.20.730.20.1.670Columnf2000EASMSTI6Port2PathCostLocalread-writecurrentf2000EAS Series card MSTI Port Configuration: MSTI6 Normal Port2 Configuration - Path Cost Valid values are in the range 0 to 200000000. Setting 0 means Auto p…
1.3.6.1.4.1.4756.20.730.20.1.671Columnf2000EASMSTI6Port2PriorityLocalread-writecurrentf2000EAS Series card MSTI Port Configuration: MSTI6 Normal Port2 Configuration - Priority
1.3.6.1.4.1.4756.20.730.20.1.672Columnf2000EASMSTI6Port3PathCostLocalread-writecurrentf2000EAS Series card MSTI Port Configuration: MSTI6 Normal Port3 Configuration - Path Cost Valid values are in the range 0 to 200000000. Setting 0 means Auto p…
1.3.6.1.4.1.4756.20.730.20.1.673Columnf2000EASMSTI6Port3PriorityLocalread-writecurrentf2000EAS Series card MSTI Port Configuration: MSTI6 Normal Port3 Configuration - Priority
1.3.6.1.4.1.4756.20.730.20.1.674Columnf2000EASMSTI6Port4PathCostLocalread-writecurrentf2000EAS Series card MSTI Port Configuration: MSTI6 Normal Port4 Configuration - Path Cost Valid values are in the range 0 to 200000000. Setting 0 means Auto p…
1.3.6.1.4.1.4756.20.730.20.1.675Columnf2000EASMSTI6Port4PriorityLocalread-writecurrentf2000EAS Series card MSTI Port Configuration: MSTI6 Normal Port4 Configuration - Priority
1.3.6.1.4.1.4756.20.730.20.1.676Columnf2000EASMSTI7AggregatedPathCostLocalread-writecurrentf2000EAS Series card MSTI Port Configuration: MSTI7 Aggregated Ports Configuration - Path Cost Valid values are in the range 0 to 200000000. Setting 0 means Au…
1.3.6.1.4.1.4756.20.730.20.1.677Columnf2000EASMSTI7AggregatedPriorityLocalread-writecurrentf2000EAS Series card MSTI Port Configuration: MSTI7 Aggregated Ports Configuration - Priority
1.3.6.1.4.1.4756.20.730.20.1.678Columnf2000EASMSTI7Port1PathCostLocalread-writecurrentf2000EAS Series card MSTI Port Configuration: MSTI1 Normal Port1 Configuration - Path Cost Valid values are in the range 0 to 200000000. Setting 0 means Auto p…
1.3.6.1.4.1.4756.20.730.20.1.679Columnf2000EASMSTI7Port1PriorityLocalread-writecurrentf2000EAS Series card MSTI Port Configuration: MSTI1 Normal Port7 Configuration - Priority
1.3.6.1.4.1.4756.20.730.20.1.680Columnf2000EASMSTI7Port2PathCostLocalread-writecurrentf2000EAS Series card MSTI Port Configuration: MSTI7 Normal Port2 Configuration - Path Cost Valid values are in the range 0 to 200000000. Setting 0 means Auto p…
1.3.6.1.4.1.4756.20.730.20.1.681Columnf2000EASMSTI7Port2PriorityLocalread-writecurrentf2000EAS Series card MSTI Port Configuration: MSTI7 Normal Port2 Configuration - Priority
1.3.6.1.4.1.4756.20.730.20.1.682Columnf2000EASMSTI7Port3PathCostLocalread-writecurrentf2000EAS Series card MSTI Port Configuration: MSTI7 Normal Port3 Configuration - Path Cost Valid values are in the range 0 to 200000000. Setting 0 means Auto p…
1.3.6.1.4.1.4756.20.730.20.1.683Columnf2000EASMSTI7Port3PriorityLocalread-writecurrentf2000EAS Series card MSTI Port Configuration: MSTI7 Normal Port3 Configuration - Priority
1.3.6.1.4.1.4756.20.730.20.1.684Columnf2000EASMSTI7Port4PathCostLocalread-writecurrentf2000EAS Series card MSTI Port Configuration: MSTI7 Normal Port4 Configuration - Path Cost Valid values are in the range 0 to 200000000. Setting 0 means Auto p…
1.3.6.1.4.1.4756.20.730.20.1.685Columnf2000EASMSTI7Port4PriorityLocalread-writecurrentf2000EAS Series card MSTI Port Configuration: MSTI7 Normal Port4 Configuration - Priority
1.3.6.1.4.1.4756.20.730.20.1.686Columnf2000EASCISTBridgeIDLocalread-onlycurrentf2000EAS Series card STP Bridges status: CIST - Bridge ID
1.3.6.1.4.1.4756.20.730.20.1.687Columnf2000EASCISTRootIDLocalread-onlycurrentf2000EAS Series card STP Bridges status: CIST - Root ID
1.3.6.1.4.1.4756.20.730.20.1.688Columnf2000EASCISTRootPortLocalread-onlycurrentf2000EAS Series card STP Bridges status: CIST - Root Port
1.3.6.1.4.1.4756.20.730.20.1.689Columnf2000EASCISTRootCostLocalread-onlycurrentf2000EAS Series card STP Bridges status: CIST - Root Cost
1.3.6.1.4.1.4756.20.730.20.1.690Columnf2000EASCISTTopologyFlagLocalread-onlycurrentf2000EAS Series card STP Bridges status: CIST - Topology Flag
1.3.6.1.4.1.4756.20.730.20.1.691Columnf2000EASCISTTopologyChangeLastLocalread-onlycurrentf2000EAS Series card STP Bridges status: CIST - Topology Change Last
1.3.6.1.4.1.4756.20.730.20.1.692Columnf2000EASMSTI1BridgeIDLocalread-onlycurrentf2000EAS Series card STP Bridges status: MSTI1 - Bridge ID
1.3.6.1.4.1.4756.20.730.20.1.693Columnf2000EASMSTI1RootIDLocalread-onlycurrentf2000EAS Series card STP Bridges status: MSTI1 - Root ID
1.3.6.1.4.1.4756.20.730.20.1.694Columnf2000EASMSTI1RootPortLocalread-onlycurrentf2000EAS Series card STP Bridges status: MSTI1 - Root ID
1.3.6.1.4.1.4756.20.730.20.1.695Columnf2000EASMSTI1RootCostLocalread-onlycurrentf2000EAS Series card STP Bridges status: MSTI1 - Root Cost
1.3.6.1.4.1.4756.20.730.20.1.696Columnf2000EASMSTI1TopologyFlagLocalread-onlycurrentf2000EAS Series card STP Bridges status: MSTI1 - Topology Flag
1.3.6.1.4.1.4756.20.730.20.1.697Columnf2000EASMSTI1TopologyChangeLastLocalread-onlycurrentf2000EAS Series card STP Bridges status: MSTI1 - Topology Change Last
1.3.6.1.4.1.4756.20.730.20.1.698Columnf2000EASMSTI2BridgeIDLocalread-onlycurrentf2000EAS Series card STP Bridges status: MSTI2 - Bridge ID
1.3.6.1.4.1.4756.20.730.20.1.699Columnf2000EASMSTI2RootIDLocalread-onlycurrentf2000EAS Series card STP Bridges status: MSTI2 - Root ID
1.3.6.1.4.1.4756.20.730.20.1.700Columnf2000EASMSTI2RootPortLocalread-onlycurrentf2000EAS Series card STP Bridges status: MSTI2 - Root ID
1.3.6.1.4.1.4756.20.730.20.1.701Columnf2000EASMSTI2RootCostLocalread-onlycurrentf2000EAS Series card STP Bridges status: MSTI2 - Root Cost
1.3.6.1.4.1.4756.20.730.20.1.702Columnf2000EASMSTI2TopologyFlagLocalread-onlycurrentf2000EAS Series card STP Bridges status: MSTI2 - Topology Flag
1.3.6.1.4.1.4756.20.730.20.1.703Columnf2000EASMSTI2TopologyChangeLastLocalread-onlycurrentf2000EAS Series card STP Bridges status: MSTI2 - Topology Change Last
1.3.6.1.4.1.4756.20.730.20.1.704Columnf2000EASMSTI3BridgeIDLocalread-onlycurrentf2000EAS Series card STP Bridges status: MSTI3 - Bridge ID
1.3.6.1.4.1.4756.20.730.20.1.705Columnf2000EASMSTI3RootIDLocalread-onlycurrentf2000EAS Series card STP Bridges status: MSTI3 - Root ID
1.3.6.1.4.1.4756.20.730.20.1.706Columnf2000EASMSTI3RootPortLocalread-onlycurrentf2000EAS Series card STP Bridges status: MSTI3 - Root ID
1.3.6.1.4.1.4756.20.730.20.1.707Columnf2000EASMSTI3RootCostLocalread-onlycurrentf2000EAS Series card STP Bridges status: MSTI3 - Root Cost
1.3.6.1.4.1.4756.20.730.20.1.708Columnf2000EASMSTI3TopologyFlagLocalread-onlycurrentf2000EAS Series card STP Bridges status: MSTI3 - Topology Flag
1.3.6.1.4.1.4756.20.730.20.1.709Columnf2000EASMSTI3TopologyChangeLastLocalread-onlycurrentf2000EAS Series card STP Bridges status: MSTI3 - Topology Change Last
1.3.6.1.4.1.4756.20.730.20.1.710Columnf2000EASMSTI4BridgeIDLocalread-onlycurrentf2000EAS Series card STP Bridges status: MSTI4 - Bridge ID
1.3.6.1.4.1.4756.20.730.20.1.711Columnf2000EASMSTI4RootIDLocalread-onlycurrentf2000EAS Series card STP Bridges status: MSTI4 - Root ID
1.3.6.1.4.1.4756.20.730.20.1.712Columnf2000EASMSTI4RootPortLocalread-onlycurrentf2000EAS Series card STP Bridges status: MSTI4 - Root ID
1.3.6.1.4.1.4756.20.730.20.1.713Columnf2000EASMSTI4RootCostLocalread-onlycurrentf2000EAS Series card STP Bridges status: MSTI4 - Root Cost
1.3.6.1.4.1.4756.20.730.20.1.714Columnf2000EASMSTI4TopologyFlagLocalread-onlycurrentf2000EAS Series card STP Bridges status: MSTI4 - Topology Flag
1.3.6.1.4.1.4756.20.730.20.1.715Columnf2000EASMSTI4TopologyChangeLastLocalread-onlycurrentf2000EAS Series card STP Bridges status: MSTI4 - Topology Change Last
1.3.6.1.4.1.4756.20.730.20.1.716Columnf2000EASMSTI5BridgeIDLocalread-onlycurrentf2000EAS Series card STP Bridges status: MSTI5 - Bridge ID
1.3.6.1.4.1.4756.20.730.20.1.717Columnf2000EASMSTI5RootIDLocalread-onlycurrentf2000EAS Series card STP Bridges status: MSTI5 - Root ID
1.3.6.1.4.1.4756.20.730.20.1.718Columnf2000EASMSTI5RootPortLocalread-onlycurrentf2000EAS Series card STP Bridges status: MSTI5 - Root ID
1.3.6.1.4.1.4756.20.730.20.1.719Columnf2000EASMSTI5RootCostLocalread-onlycurrentf2000EAS Series card STP Bridges status: MSTI5 - Root Cost
1.3.6.1.4.1.4756.20.730.20.1.720Columnf2000EASMSTI5TopologyFlagLocalread-onlycurrentf2000EAS Series card STP Bridges status: MSTI5 - Topology Flag
1.3.6.1.4.1.4756.20.730.20.1.721Columnf2000EASMSTI5TopologyChangeLastLocalread-onlycurrentf2000EAS Series card STP Bridges status: MSTI5 - Topology Change Last
1.3.6.1.4.1.4756.20.730.20.1.722Columnf2000EASMSTI6BridgeIDLocalread-onlycurrentf2000EAS Series card STP Bridges status: MSTI6 - Bridge ID
1.3.6.1.4.1.4756.20.730.20.1.723Columnf2000EASMSTI6RootIDLocalread-onlycurrentf2000EAS Series card STP Bridges status: MSTI6 - Root ID
1.3.6.1.4.1.4756.20.730.20.1.724Columnf2000EASMSTI6RootPortLocalread-onlycurrentf2000EAS Series card STP Bridges status: MSTI6 - Root ID
1.3.6.1.4.1.4756.20.730.20.1.725Columnf2000EASMSTI6RootCostLocalread-onlycurrentf2000EAS Series card STP Bridges status: MSTI6 - Root Cost
1.3.6.1.4.1.4756.20.730.20.1.726Columnf2000EASMSTI6TopologyFlagLocalread-onlycurrentf2000EAS Series card STP Bridges status: MSTI6 - Topology Flag
1.3.6.1.4.1.4756.20.730.20.1.727Columnf2000EASMSTI6TopologyChangeLastLocalread-onlycurrentf2000EAS Series card STP Bridges status: MSTI6 - Topology Change Last
1.3.6.1.4.1.4756.20.730.20.1.728Columnf2000EASMSTI7BridgeIDLocalread-onlycurrentf2000EAS Series card STP Bridges status: MSTI7 - Bridge ID
1.3.6.1.4.1.4756.20.730.20.1.729Columnf2000EASMSTI7RootIDLocalread-onlycurrentf2000EAS Series card STP Bridges status: MSTI7 - Root ID
1.3.6.1.4.1.4756.20.730.20.1.730Columnf2000EASMSTI7RootPortLocalread-onlycurrentf2000EAS Series card STP Bridges status: MSTI7 - Root ID
1.3.6.1.4.1.4756.20.730.20.1.731Columnf2000EASMSTI7RootCostLocalread-onlycurrentf2000EAS Series card STP Bridges status: MSTI7 - Root Cost
1.3.6.1.4.1.4756.20.730.20.1.732Columnf2000EASMSTI7TopologyFlagLocalread-onlycurrentf2000EAS Series card STP Bridges status: MSTI7 - Topology Flag
1.3.6.1.4.1.4756.20.730.20.1.733Columnf2000EASMSTI7TopologyChangeLastLocalread-onlycurrentf2000EAS Series card STP Bridges status: MSTI7 - Topology Change Last
1.3.6.1.4.1.4756.20.730.20.1.734Columnf2000EASSTPPortStatusInst1PortLocalread-onlycurrentf2000EAS Series card STP Port status: Instance1 - Port
1.3.6.1.4.1.4756.20.730.20.1.735Columnf2000EASSTPPortStatusInst1CISTRoleLocalread-onlycurrentf2000EAS Series card STP Port status: Instance1 - CIST Role
1.3.6.1.4.1.4756.20.730.20.1.736Columnf2000EASSTPPortStatusInst1CISTStateLocalread-onlycurrentf2000EAS Series card STP Port status: Instance1 - CIST State
1.3.6.1.4.1.4756.20.730.20.1.737Columnf2000EASSTPPortStatusInst1UptimeLocalread-onlycurrentf2000EAS Series card STP Port status: Instance1 -Uptime
1.3.6.1.4.1.4756.20.730.20.1.738Columnf2000EASSTPPortStatusInst2PortLocalread-onlycurrentf2000EAS Series card STP Port status: Instance2 - Port
1.3.6.1.4.1.4756.20.730.20.1.739Columnf2000EASSTPPortStatusInst2CISTRoleLocalread-onlycurrentf2000EAS Series card STP Port status: Instance2 - CIST Role
1.3.6.1.4.1.4756.20.730.20.1.740Columnf2000EASSTPPortStatusInst2CISTStateLocalread-onlycurrentf2000EAS Series card STP Port status: Instance2 - CIST State
1.3.6.1.4.1.4756.20.730.20.1.741Columnf2000EASSTPPortStatusInst2UptimeLocalread-onlycurrentf2000EAS Series card STP Port status: Instance2 -Uptime
1.3.6.1.4.1.4756.20.730.20.1.742Columnf2000EASSTPPortStatusInst3PortLocalread-onlycurrentf2000EAS Series card STP Port status: Instance3 - Port
1.3.6.1.4.1.4756.20.730.20.1.743Columnf2000EASSTPPortStatusInst3CISTRoleLocalread-onlycurrentf2000EAS Series card STP Port status: Instance3 - CIST Role
1.3.6.1.4.1.4756.20.730.20.1.744Columnf2000EASSTPPortStatusInst3CISTStateLocalread-onlycurrentf2000EAS Series card STP Port status: Instance3 - CIST State
1.3.6.1.4.1.4756.20.730.20.1.745Columnf2000EASSTPPortStatusInst3UptimeLocalread-onlycurrentf2000EAS Series card STP Port status: Instance3 -Uptime
1.3.6.1.4.1.4756.20.730.20.1.746Columnf2000EASSTPPortStatusInst4PortLocalread-onlycurrentf2000EAS Series card STP Port status: Instance4 - Port
1.3.6.1.4.1.4756.20.730.20.1.747Columnf2000EASSTPPortStatusInst4CISTRoleLocalread-onlycurrentf2000EAS Series card STP Port status: Instance4 - CIST Role
1.3.6.1.4.1.4756.20.730.20.1.748Columnf2000EASSTPPortStatusInst4CISTStateLocalread-onlycurrentf2000EAS Series card STP Port status: Instance4 - CIST State
1.3.6.1.4.1.4756.20.730.20.1.749Columnf2000EASSTPPortStatusInst4UptimeLocalread-onlycurrentf2000EAS Series card STP Port status: Instance4 -Uptime
1.3.6.1.4.1.4756.20.730.20.1.750Columnf2000EASSTPStatisticsPort1TxMSTPLocalread-onlycurrentf2000EAS Series card STP Port Statistics: Port1 -Transmitted MSTP
1.3.6.1.4.1.4756.20.730.20.1.751Columnf2000EASSTPStatisticsPort1TxRSTPLocalread-onlycurrentf2000EAS Series card STP Port Statistics: Port1 -Transmitted RSTP
1.3.6.1.4.1.4756.20.730.20.1.752Columnf2000EASSTPStatisticsPort1TxSTPLocalread-onlycurrentf2000EAS Series card STP Port Statistics: Port1 -Transmitted RSTP
1.3.6.1.4.1.4756.20.730.20.1.753Columnf2000EASSTPStatisticsPort1TxTCNLocalread-onlycurrentf2000EAS Series card STP Port Statistics: Port1 -Transmitted RSTP
1.3.6.1.4.1.4756.20.730.20.1.754Columnf2000EASSTPStatisticsPort1RxMSTPLocalread-onlycurrentf2000EAS Series card STP Port Statistics: Port1 -Received MSTP
1.3.6.1.4.1.4756.20.730.20.1.755Columnf2000EASSTPStatisticsPort1RxRSTPLocalread-onlycurrentf2000EAS Series card STP Port Statistics: Port1 -Received RSTP
1.3.6.1.4.1.4756.20.730.20.1.756Columnf2000EASSTPStatisticsPort1RxSTPLocalread-onlycurrentf2000EAS Series card STP Port Statistics: Port1 -Received RSTP
1.3.6.1.4.1.4756.20.730.20.1.757Columnf2000EASSTPStatisticsPort1RxTCNLocalread-onlycurrentf2000EAS Series card STP Port Statistics: Port1 -Received RSTP
1.3.6.1.4.1.4756.20.730.20.1.758Columnf2000EASSTPStatisticsPort1DiscardUnknowLocalread-onlycurrentf2000EAS Series card STP Port Statistics: Port1 -Discarded Unknown
1.3.6.1.4.1.4756.20.730.20.1.759Columnf2000EASSTPStatisticsPort1DiscardIllegalLocalread-onlycurrentf2000EAS Series card STP Port Statistics: Port1 -Discarded Illegal
1.3.6.1.4.1.4756.20.730.20.1.760Columnf2000EASSTPStatisticsPort2TxMSTPLocalread-onlycurrentf2000EAS Series card STP Port Statistics: Port2 -Transmitted MSTP
1.3.6.1.4.1.4756.20.730.20.1.761Columnf2000EASSTPStatisticsPort2TxRSTPLocalread-onlycurrentf2000EAS Series card STP Port Statistics: Port2 -Transmitted RSTP
1.3.6.1.4.1.4756.20.730.20.1.762Columnf2000EASSTPStatisticsPort2TxSTPLocalread-onlycurrentf2000EAS Series card STP Port Statistics: Port2 -Transmitted RSTP
1.3.6.1.4.1.4756.20.730.20.1.763Columnf2000EASSTPStatisticsPort2TxTCNLocalread-onlycurrentf2000EAS Series card STP Port Statistics: Port2 -Transmitted RSTP
1.3.6.1.4.1.4756.20.730.20.1.764Columnf2000EASSTPStatisticsPort2RxMSTPLocalread-onlycurrentf2000EAS Series card STP Port Statistics: Port2 -Received MSTP
1.3.6.1.4.1.4756.20.730.20.1.765Columnf2000EASSTPStatisticsPort2RxRSTPLocalread-onlycurrentf2000EAS Series card STP Port Statistics: Port1 -Received RSTP
1.3.6.1.4.1.4756.20.730.20.1.766Columnf2000EASSTPStatisticsPort2RxSTPLocalread-onlycurrentf2000EAS Series card STP Port Statistics: Port2 -Received RSTP
1.3.6.1.4.1.4756.20.730.20.1.767Columnf2000EASSTPStatisticsPort2RxTCNLocalread-onlycurrentf2000EAS Series card STP Port Statistics: Port2 -Received RSTP
1.3.6.1.4.1.4756.20.730.20.1.768Columnf2000EASSTPStatisticsPort2DiscardUnknowLocalread-onlycurrentf2000EAS Series card STP Port Statistics: Port2 -Discarded Unknown
1.3.6.1.4.1.4756.20.730.20.1.769Columnf2000EASSTPStatisticsPort2DiscardIllegalLocalread-onlycurrentf2000EAS Series card STP Port Statistics: Port2 -Discarded Illegal
1.3.6.1.4.1.4756.20.730.20.1.770Columnf2000EASSTPStatisticsPort3TxMSTPLocalread-onlycurrentf2000EAS Series card STP Port Statistics: Port3 -Transmitted MSTP
1.3.6.1.4.1.4756.20.730.20.1.771Columnf2000EASSTPStatisticsPort3TxRSTPLocalread-onlycurrentf2000EAS Series card STP Port Statistics: Port3 -Transmitted RSTP
1.3.6.1.4.1.4756.20.730.20.1.772Columnf2000EASSTPStatisticsPort3TxSTPLocalread-onlycurrentf2000EAS Series card STP Port Statistics: Port3 -Transmitted RSTP
1.3.6.1.4.1.4756.20.730.20.1.773Columnf2000EASSTPStatisticsPort3TxTCNLocalread-onlycurrentf2000EAS Series card STP Port Statistics: Port3 -Transmitted RSTP
1.3.6.1.4.1.4756.20.730.20.1.774Columnf2000EASSTPStatisticsPort3RxMSTPLocalread-onlycurrentf2000EAS Series card STP Port Statistics: Port3 -Received MSTP
1.3.6.1.4.1.4756.20.730.20.1.775Columnf2000EASSTPStatisticsPort3RxRSTPLocalread-onlycurrentf2000EAS Series card STP Port Statistics: Port3 -Received RSTP
1.3.6.1.4.1.4756.20.730.20.1.776Columnf2000EASSTPStatisticsPort3RxSTPLocalread-onlycurrentf2000EAS Series card STP Port Statistics: Port3 -Received RSTP
1.3.6.1.4.1.4756.20.730.20.1.777Columnf2000EASSTPStatisticsPort3RxTCNLocalread-onlycurrentf2000EAS Series card STP Port Statistics: Port3 -Received RSTP
1.3.6.1.4.1.4756.20.730.20.1.778Columnf2000EASSTPStatisticsPort3DiscardUnknowLocalread-onlycurrentf2000EAS Series card STP Port Statistics: Port3 -Discarded Unknown
1.3.6.1.4.1.4756.20.730.20.1.779Columnf2000EASSTPStatisticsPort3DiscardIllegalLocalread-onlycurrentf2000EAS Series card STP Port Statistics: Port3 -Discarded Illegal
1.3.6.1.4.1.4756.20.730.20.1.780Columnf2000EASSTPStatisticsPort4TxMSTPLocalread-onlycurrentf2000EAS Series card STP Port Statistics: Port4 -Transmitted MSTP
1.3.6.1.4.1.4756.20.730.20.1.781Columnf2000EASSTPStatisticsPort4TxRSTPLocalread-onlycurrentf2000EAS Series card STP Port Statistics: Port4 -Transmitted RSTP
1.3.6.1.4.1.4756.20.730.20.1.782Columnf2000EASSTPStatisticsPort4TxSTPLocalread-onlycurrentf2000EAS Series card STP Port Statistics: Port4 -Transmitted RSTP
1.3.6.1.4.1.4756.20.730.20.1.783Columnf2000EASSTPStatisticsPort4TxTCNLocalread-onlycurrentf2000EAS Series card STP Port Statistics: Port4 -Transmitted RSTP
1.3.6.1.4.1.4756.20.730.20.1.784Columnf2000EASSTPStatisticsPort4RxMSTPLocalread-onlycurrentf2000EAS Series card STP Port Statistics: Port4 -Received MSTP
1.3.6.1.4.1.4756.20.730.20.1.785Columnf2000EASSTPStatisticsPort4RxRSTPLocalread-onlycurrentf2000EAS Series card STP Port Statistics: Port4 -Received RSTP
1.3.6.1.4.1.4756.20.730.20.1.786Columnf2000EASSTPStatisticsPort4RxSTPLocalread-onlycurrentf2000EAS Series card STP Port Statistics: Port4 -Received RSTP
1.3.6.1.4.1.4756.20.730.20.1.787Columnf2000EASSTPStatisticsPort4RxTCNLocalread-onlycurrentf2000EAS Series card STP Port Statistics: Port4 -Received RSTP
1.3.6.1.4.1.4756.20.730.20.1.788Columnf2000EASSTPStatisticsPort4DiscardUnknowLocalread-onlycurrentf2000EAS Series card STP Port Statistics: Port4 -Discarded Unknown
1.3.6.1.4.1.4756.20.730.20.1.789Columnf2000EASSTPStatisticsPort4DiscardIllegalLocalread-onlycurrentf2000EAS Series card STP Port Statistics: Port4 -Discarded Illegal
1.3.6.1.4.1.4756.20.730.20.1.790Columnf2000EASSTPStatisticsPortClearCounterLocalread-writecurrentf2000EAS Series card STP Port Statistics: Clear Counters 0: OFff 1: Action
1.3.6.1.4.1.4756.20.730.20.1.791Columnf2000EASAllowedAccessVLANsLocalread-writecurrentf2000EAS Series card Global VLAN Configuration: Allowed Access VLANs By default, only VLAN 1 is enabled. More VLANs may be created by using a list syntax where…
1.3.6.1.4.1.4756.20.730.20.1.792Columnf2000EASVlanEthertypeLocalread-writecurrentf2000EAS Series card Global VLAN Configuration: Ethertype for Custom S-ports The format of 'Ethernet Type' is restricted to 0x600-0xFFFF
1.3.6.1.4.1.4756.20.730.20.1.793Columnf2000EASPort1VlanModeLocalread-writecurrentf2000EAS Series card Port VLAN Configuration : Port1 - Mode 0: Access 1: Trunk 2: Hybrid
1.3.6.1.4.1.4756.20.730.20.1.794Columnf2000EASPort1VlanIDLocalread-writecurrentf2000EAS Series card Port VLAN Configuration : Port1 - VLAN ID
1.3.6.1.4.1.4756.20.730.20.1.795Columnf2000EASPort1VlanTypeLocalread-writecurrentf2000EAS Series card Port VLAN Configuration : Port1 - VLAN Type 0: Unaware 1: C-port 2: S-port 3: S-custom-port
1.3.6.1.4.1.4756.20.730.20.1.796Columnf2000EASPort1VlanIngressFilteringLocalread-writecurrentf2000EAS Series card Port VLAN Configuration : Port1 - Ingress Filtering 0: Off 1: On
1.3.6.1.4.1.4756.20.730.20.1.797Columnf2000EASPort1VlanIngressAcceptanceLocalread-writecurrentf2000EAS Series card Port VLAN Configuration : Port1 - Ingress Acceptance 0: Tagged and untagged 1: Tagged only 2: Untagged only
1.3.6.1.4.1.4756.20.730.20.1.798Columnf2000EASPort1VlanEgressTaggingLocalread-writecurrentf2000EAS Series card Port VLAN Configuration : Port1 - Egress Tagging 0: Untag port vlan 1: Tag all 2: Untag all
1.3.6.1.4.1.4756.20.730.20.1.799Columnf2000EASPort1VlanEgressTaggedSpecificallyUntagLocalread-writecurrentPorts in Hybrid mode may specify the tagging of frames with VID on egress, which overrules the Egress Tagging setting. Frames classified to these VLANs are tra…
1.3.6.1.4.1.4756.20.730.20.1.800Columnf2000EASPort1VlanEgressTaggedSpecificallyCtagLocalread-writecurrentPorts in Hybrid mode may specify the tagging of frames with VID on egress, which overrules the Egress Tagging setting. Frames classified to these VLANs are tra…
1.3.6.1.4.1.4756.20.730.20.1.801Columnf2000EASPort1VlanEgressTaggedSpecificallyStagLocalread-writecurrentPorts in Hybrid mode may specify the tagging of frames with VID on egress, which overrules the Egress Tagging setting. Frames classified to these VLANs are tra…
1.3.6.1.4.1.4756.20.730.20.1.802Columnf2000EASPort1VlanEgressTaggedSpecificallySCtagLocalread-writecurrentPorts in Hybrid mode may specify the tagging of frames with VID on egress, which overrules the Egress Tagging setting. Frames classified to these VLANs are tra…
1.3.6.1.4.1.4756.20.730.20.1.803Columnf2000EASPort1AllowedVLANSLocalread-writecurrentf2000EAS Series card Global VLAN Configuration: Port1 - Allowed VLANs By default, only VLAN 1 is enabled. More VLANs may be created by using a list syntax wher…
1.3.6.1.4.1.4756.20.730.20.1.804Columnf2000EASPort2VlanModeLocalread-writecurrentf2000EAS Series card Port VLAN Configuration : Port2 - Mode 0: Access 1: Trunk 2: Hybrid
1.3.6.1.4.1.4756.20.730.20.1.805Columnf2000EASPort2VlanIDLocalread-writecurrentf2000EAS Series card Port VLAN Configuration : Port2 - VLAN ID
1.3.6.1.4.1.4756.20.730.20.1.806Columnf2000EASPort2VlanTypeLocalread-writecurrentf2000EAS Series card Port VLAN Configuration : Port2 - VLAN Type 0: Unaware 1: C-port 2: S-port 3: S-custom-port
1.3.6.1.4.1.4756.20.730.20.1.807Columnf2000EASPort2VlanIngressFilteringLocalread-writecurrentf2000EAS Series card Port VLAN Configuration : Port2 - Ingress Filtering 0: Off 1: On
1.3.6.1.4.1.4756.20.730.20.1.808Columnf2000EASPort2VlanIngressAcceptanceLocalread-writecurrentf2000EAS Series card Port VLAN Configuration : Por2 - Ingress Acceptance 0: Tagged and untagged 1: Tagged only 2: Untagged only
1.3.6.1.4.1.4756.20.730.20.1.809Columnf2000EASPort2VlanEgressTaggingLocalread-writecurrentf2000EAS Series card Port VLAN Configuration : Port2 - Egress Tagging 0: Untag port vlan 1: Tag all 2: Untag all
1.3.6.1.4.1.4756.20.730.20.1.810Columnf2000EASPort2VlanEgressTaggedSpecificallyUntagLocalread-writecurrentPorts in Hybrid mode may specify the tagging of frames with VID on egress, which overrules the Egress Tagging setting. Frames classified to these VLANs are tra…
1.3.6.1.4.1.4756.20.730.20.1.811Columnf2000EASPort2VlanEgressTaggedSpecificallyCtagLocalread-writecurrentPorts in Hybrid mode may specify the tagging of frames with VID on egress, which overrules the Egress Tagging setting. Frames classified to these VLANs are tra…
1.3.6.1.4.1.4756.20.730.20.1.812Columnf2000EASPort2VlanEgressTaggedSpecificallyStagLocalread-writecurrentPorts in Hybrid mode may specify the tagging of frames with VID on egress, which overrules the Egress Tagging setting. Frames classified to these VLANs are tra…
1.3.6.1.4.1.4756.20.730.20.1.813Columnf2000EASPort2VlanEgressTaggedSpecificallySCtagLocalread-writecurrentPorts in Hybrid mode may specify the tagging of frames with VID on egress, which overrules the Egress Tagging setting. Frames classified to these VLANs are tra…
1.3.6.1.4.1.4756.20.730.20.1.814Columnf2000EASPort2AllowedVLANSLocalread-writecurrentf2000EAS Series card Global VLAN Configuration: Port2 - Allowed VLANs By default, only VLAN 1 is enabled. More VLANs may be created by using a list syntax wher…
1.3.6.1.4.1.4756.20.730.20.1.815Columnf2000EASPort3VlanModeLocalread-writecurrentf2000EAS Series card Port VLAN Configuration : Port3 - Mode 0: Access 1: Trunk 2: Hybrid
1.3.6.1.4.1.4756.20.730.20.1.816Columnf2000EASPort3VlanIDLocalread-writecurrentf2000EAS Series card Port VLAN Configuration : Port3 - VLAN ID
1.3.6.1.4.1.4756.20.730.20.1.817Columnf2000EASPort3VlanTypeLocalread-writecurrentf2000EAS Series card Port VLAN Configuration : Port3 - VLAN Type 0: Unaware 1: C-port 2: S-port 3: S-custom-port
1.3.6.1.4.1.4756.20.730.20.1.818Columnf2000EASPort3VlanIngressFilteringLocalread-writecurrentf2000EAS Series card Port VLAN Configuration : Port3 - Ingress Filtering 0: Off 1: On
1.3.6.1.4.1.4756.20.730.20.1.819Columnf2000EASPort3VlanIngressAcceptanceLocalread-writecurrentf2000EAS Series card Port VLAN Configuration : Port3 - Ingress Acceptance 0: Tagged and untagged 1: Tagged only 2: Untagged only
1.3.6.1.4.1.4756.20.730.20.1.820Columnf2000EASPort3VlanEgressTaggingLocalread-writecurrentf2000EAS Series card Port VLAN Configuration : Port3 - Egress Tagging 0: Untag port vlan 1: Tag all 2: Untag all
1.3.6.1.4.1.4756.20.730.20.1.821Columnf2000EASPort3VlanEgressTaggedSpecificallyUntagLocalread-writecurrentPorts in Hybrid mode may specify the tagging of frames with VID on egress, which overrules the Egress Tagging setting. Frames classified to these VLANs are tra…
1.3.6.1.4.1.4756.20.730.20.1.822Columnf2000EASPort3VlanEgressTaggedSpecificallyCtagLocalread-writecurrentPorts in Hybrid mode may specify the tagging of frames with VID on egress, which overrules the Egress Tagging setting. Frames classified to these VLANs are tra…
1.3.6.1.4.1.4756.20.730.20.1.823Columnf2000EASPort3VlanEgressTaggedSpecificallyStagLocalread-writecurrentPorts in Hybrid mode may specify the tagging of frames with VID on egress, which overrules the Egress Tagging setting. Frames classified to these VLANs are tra…
1.3.6.1.4.1.4756.20.730.20.1.824Columnf2000EASPort3VlanEgressTaggedSpecificallySCtagLocalread-writecurrentPorts in Hybrid mode may specify the tagging of frames with VID on egress, which overrules the Egress Tagging setting. Frames classified to these VLANs are tra…
1.3.6.1.4.1.4756.20.730.20.1.825Columnf2000EASPort3AllowedVLANSLocalread-writecurrentf2000EAS Series card Global VLAN Configuration: Port3 - Allowed VLANs By default, only VLAN 1 is enabled. More VLANs may be created by using a list syntax wher…
1.3.6.1.4.1.4756.20.730.20.1.826Columnf2000EASPort4VlanModeLocalread-writecurrentf2000EAS Series card Port VLAN Configuration : Port4 - Mode 0: Access 1: Trunk 2: Hybrid
1.3.6.1.4.1.4756.20.730.20.1.827Columnf2000EASPort4VlanIDLocalread-writecurrentf2000EAS Series card Port VLAN Configuration : Port4 - VLAN ID
1.3.6.1.4.1.4756.20.730.20.1.828Columnf2000EASPort4VlanTypeLocalread-writecurrentf2000EAS Series card Port VLAN Configuration : Port4 - VLAN Type 0: Unaware 1: C-port 2: S-port 3: S-custom-port
1.3.6.1.4.1.4756.20.730.20.1.829Columnf2000EASPort4VlanIngressFilteringLocalread-writecurrentf2000EAS Series card Port VLAN Configuration : Port4 - Ingress Filtering 0: Off 1: On
1.3.6.1.4.1.4756.20.730.20.1.830Columnf2000EASPort4VlanIngressAcceptanceLocalread-writecurrentf2000EAS Series card Port VLAN Configuration : Port4 - Ingress Acceptance 0: Tagged and untagged 1: Tagged only 2: Untagged only
1.3.6.1.4.1.4756.20.730.20.1.831Columnf2000EASPort4VlanEgressTaggingLocalread-writecurrentf2000EAS Series card Port VLAN Configuration : Port4 - Egress Tagging 0: Untag port vlan 1: Tag all 2: Untag all
1.3.6.1.4.1.4756.20.730.20.1.832Columnf2000EASPort4VlanEgressTaggedSpecificallyUntagLocalread-writecurrentPorts in Hybrid mode may specify the tagging of frames with VID on egress, which overrules the Egress Tagging setting. Frames classified to these VLANs are tra…
1.3.6.1.4.1.4756.20.730.20.1.833Columnf2000EASPort4VlanEgressTaggedSpecificallyCtagLocalread-writecurrentPorts in Hybrid mode may specify the tagging of frames with VID on egress, which overrules the Egress Tagging setting. Frames classified to these VLANs are tra…
1.3.6.1.4.1.4756.20.730.20.1.834Columnf2000EASPort4VlanEgressTaggedSpecificallyStagLocalread-writecurrentPorts in Hybrid mode may specify the tagging of frames with VID on egress, which overrules the Egress Tagging setting. Frames classified to these VLANs are tra…
1.3.6.1.4.1.4756.20.730.20.1.835Columnf2000EASPort4VlanEgressTaggedSpecificallySCtagLocalread-writecurrentPorts in Hybrid mode may specify the tagging of frames with VID on egress, which overrules the Egress Tagging setting. Frames classified to these VLANs are tra…
1.3.6.1.4.1.4756.20.730.20.1.836Columnf2000EASPort4AllowedVLANSLocalread-writecurrentf2000EAS Series card Global VLAN Configuration: Port4 - Allowed VLANs By default, only VLAN 1 is enabled. More VLANs may be created by using a list syntax wher…
1.3.6.1.4.1.4756.20.730.20.1.837Columnf2000EASQOSPort1IngressLocalread-writecurrentf2000EAS Series card QOS Port1 Ingress Enabled 0: NO 1: YES
1.3.6.1.4.1.4756.20.730.20.1.838Columnf2000EASQOSPort1IngressRateLocalread-writecurrentf2000EAS Series card QOS Port1 Ingress Rate
1.3.6.1.4.1.4756.20.730.20.1.839Columnf2000EASQOSPort1IngressRateUnitLocalread-writecurrentf2000EAS Series card QOS Port1 Ingress Rate Unit 0: Kbps 1: Mbps 2: fps 3: kfps
1.3.6.1.4.1.4756.20.730.20.1.840Columnf2000EASQOSPort1IngressBurstSizeLocalread-writecurrentf2000EAS Series card QOS Port1 Ingress Burst Size
1.3.6.1.4.1.4756.20.730.20.1.841Columnf2000EASQOSPort2IngressLocalread-writecurrentf2000EAS Series card QOS Port2 Ingress Enabled 0: NO 1: YES
1.3.6.1.4.1.4756.20.730.20.1.842Columnf2000EASQOSPort2IngressRateLocalread-writecurrentf2000EAS Series card QOS Port2 Ingress Rate
1.3.6.1.4.1.4756.20.730.20.1.843Columnf2000EASQOSPort2IngressRateUnitLocalread-writecurrentf2000EAS Series card QOS Port2 Ingress Rate Unit 0: Kbps 1: Mbps 2: fps 3: kfps
1.3.6.1.4.1.4756.20.730.20.1.844Columnf2000EASQOSPort2IngressBurstSizeLocalread-writecurrentf2000EAS Series card QOS Port2 Ingress Burst Size
1.3.6.1.4.1.4756.20.730.20.1.845Columnf2000EASQOSPort3IngressLocalread-writecurrentf2000EAS Series card QOS Port3 Ingress Enabled 0: NO 1: YES
1.3.6.1.4.1.4756.20.730.20.1.846Columnf2000EASQOSPort3IngressRateLocalread-writecurrentf2000EAS Series card QOS Port3 Ingress Rate
1.3.6.1.4.1.4756.20.730.20.1.847Columnf2000EASQOSPort3IngressRateUnitLocalread-writecurrentf2000EAS Series card QOS Port3 Ingress Rate Unit 0: Kbps 1: Mbps 2: fps 3: kfps
1.3.6.1.4.1.4756.20.730.20.1.848Columnf2000EASQOSPort3IngressBurstSizeLocalread-writecurrentf2000EAS Series card QOS Port3 Ingress Burst Size
1.3.6.1.4.1.4756.20.730.20.1.849Columnf2000EASQOSPort4IngressLocalread-writecurrentf2000EAS Series card QOS Port4 Ingress Enabled 0: NO 1: YES
1.3.6.1.4.1.4756.20.730.20.1.850Columnf2000EASQOSPort4IngressRateLocalread-writecurrentf2000EAS Series card QOS Port4 Ingress Rate
1.3.6.1.4.1.4756.20.730.20.1.851Columnf2000EASQOSPort4IngressRateUnitLocalread-writecurrentf2000EAS Series card QOS Port4 Ingress Rate Unit 0: Kbps 1: Mbps 2: fps 3: kfps
1.3.6.1.4.1.4756.20.730.20.1.852Columnf2000EASQOSPort4IngressBurstSizeLocalread-writecurrentf2000EAS Series card QOS Port4 Ingress Burst Size
1.3.6.1.4.1.4756.20.730.20.1.853Columnf2000EASQOSPort1EgressLocalread-writecurrentf2000EAS Series card QOS Port1 Egress Enabled 0: NO 1: YES
1.3.6.1.4.1.4756.20.730.20.1.854Columnf2000EASQOSPort1EgressRateLocalread-writecurrentf2000EAS Series card QOS Port1 Egress Rate
1.3.6.1.4.1.4756.20.730.20.1.855Columnf2000EASQOSPort1EgressRateUnitLocalread-writecurrentf2000EAS Series card QOS Port1 Egress Rate Unit 0: Kbps 1: Mbps
1.3.6.1.4.1.4756.20.730.20.1.856Columnf2000EASQOSPort2EgressLocalread-writecurrentf2000EAS Series card QOS Port2 Egress Enabled 0: NO 1: YES
1.3.6.1.4.1.4756.20.730.20.1.857Columnf2000EASQOSPort2EgressRateLocalread-writecurrentf2000EAS Series card QOS Port2 Egress Rate
1.3.6.1.4.1.4756.20.730.20.1.858Columnf2000EASQOSPort2EgressRateUnitLocalread-writecurrentf2000EAS Series card QOS Port2 Egress Rate Unit 0: Kbps 1: Mbps
1.3.6.1.4.1.4756.20.730.20.1.859Columnf2000EASQOSPort3EgressLocalread-writecurrentf2000EAS Series card QOS Port3 Egress Enabled 0: NO 1: YES
1.3.6.1.4.1.4756.20.730.20.1.860Columnf2000EASQOSPort3EgressRateLocalread-writecurrentf2000EAS Series card QOS Port3 Egress Rate
1.3.6.1.4.1.4756.20.730.20.1.861Columnf2000EASQOSPort3EgressRateUnitLocalread-writecurrentf2000EAS Series card QOS Port3 Egress Rate Unit 0: Kbps 1: Mbps
1.3.6.1.4.1.4756.20.730.20.1.862Columnf2000EASQOSPort4EgressLocalread-writecurrentf2000EAS Series card QOS Port4 Egress Enabled 0: NO 1: YES
1.3.6.1.4.1.4756.20.730.20.1.863Columnf2000EASQOSPort4EgressRateLocalread-writecurrentf2000EAS Series card QOS Port4 Egress Rate
1.3.6.1.4.1.4756.20.730.20.1.864Columnf2000EASQOSPort4EgressRateUnitLocalread-writecurrentf2000EAS Series card QOS Port4 Egress Rate Unit 0: Kbps 1: Mbps
1.3.6.1.4.1.4756.20.730.20.1.865Columnf2000EASQOSUnicastLocalread-writecurrentf2000EAS Series card QOS Storm Control Configuration- Unicast 0: NO 1: YES
1.3.6.1.4.1.4756.20.730.20.1.866Columnf2000EASQOSUnicastRateLocalread-writecurrentf2000EAS Series card QOS Storm Control Configuration- Unicast Rate
1.3.6.1.4.1.4756.20.730.20.1.867Columnf2000EASQOSUnicastRateUnitLocalread-onlycurrentf2000EAS Series card QOS Unicast Rate Unit 2: Fps 3: Kfps
1.3.6.1.4.1.4756.20.730.20.1.868Columnf2000EASQOSMulticastLocalread-writecurrentf2000EAS Series card QOS Storm Control Configuration- Multicast 0: NO 1: YES
1.3.6.1.4.1.4756.20.730.20.1.869Columnf2000EASQOSMulticastRateLocalread-writecurrentf2000EAS Series card QOS Storm Control Configuration- Multicast Rate
1.3.6.1.4.1.4756.20.730.20.1.870Columnf2000EASQOSMulticastRateUnitLocalread-onlycurrentf2000EAS Series card QOS Multicast Rate Unit 2: Fps 3: Kfps
1.3.6.1.4.1.4756.20.730.20.1.871Columnf2000EASQOSBroadcastLocalread-writecurrentf2000EAS Series card QOS Storm Control Configuration- Broadcast 0: NO 1: YES
1.3.6.1.4.1.4756.20.730.20.1.872Columnf2000EASQOSBroadcastRateLocalread-writecurrentf2000EAS Series card QOS Storm Control Configuration- Broadcast Rate
1.3.6.1.4.1.4756.20.730.20.1.873Columnf2000EASQOSBroadcastRateUnitLocalread-onlycurrentf2000EAS Series card QOS Broadcast Rate Unit 2: Fps 3: Kfps
1.3.6.1.4.1.4756.20.730.20.1.874Columnf2000EASPort1LLFLogicLocalread-writecurrentf2000EAS Series card Port1 link loss forwarding - Logic 0: AND 1: OR
1.3.6.1.4.1.4756.20.730.20.1.875Columnf2000EASPort1LLFLogicPort2Localread-writecurrentf2000EAS Series card Port1 link loss forwarding - Link/Rx Loss Port2 0: NO 1: YES
1.3.6.1.4.1.4756.20.730.20.1.876Columnf2000EASPort1LLFLogicPort3Localread-writecurrentf2000EAS Series card Port1 link loss forwarding - Link/Rx Loss Port3 0: NO 1: YES
1.3.6.1.4.1.4756.20.730.20.1.877Columnf2000EASPort1LLFLogicPort4Localread-writecurrentf2000EAS Series card Port1 link loss forwarding - Link/Rx Loss Port4 0: NO 1: YES
1.3.6.1.4.1.4756.20.730.20.1.878Columnf2000EASPort2LLFLogicLocalread-writecurrentf2000EAS Series card Port2 link loss forwarding - Logic 0: AND 1: OR
1.3.6.1.4.1.4756.20.730.20.1.879Columnf2000EASPort2LLFLogicPort1Localread-writecurrentf2000EAS Series card Port2 link loss forwarding - Link/Rx Loss Port1 0: NO 1: YES
1.3.6.1.4.1.4756.20.730.20.1.880Columnf2000EASPort2LLFLogicPort3Localread-writecurrentf2000EAS Series card Port2 link loss forwarding - Link/Rx Loss Port3 0: NO 1: YES
1.3.6.1.4.1.4756.20.730.20.1.881Columnf2000EASPort2LLFLogicPort4Localread-writecurrentf2000EAS Series card Port2 link loss forwarding - Link/Rx Loss Port4 0: NO 1: YES
1.3.6.1.4.1.4756.20.730.20.1.882Columnf2000EASPort3LLFLogicLocalread-writecurrentf2000EAS Series card Port3 link loss forwarding - Logic 0: AND 1: OR
1.3.6.1.4.1.4756.20.730.20.1.883Columnf2000EASPort3LLFLogicPort1Localread-writecurrentf2000EAS Series card Port3 link loss forwarding - Link/Rx Loss Port1 0: NO 1: YES
1.3.6.1.4.1.4756.20.730.20.1.884Columnf2000EASPort3LLFLogicPort2Localread-writecurrentf2000EAS Series card Port3 link loss forwarding - Link/Rx Loss Port2 0: NO 1: YES
1.3.6.1.4.1.4756.20.730.20.1.885Columnf2000EASPort3LLFLogicPort4Localread-writecurrentf2000EAS Series card Port3 link loss forwarding - Link/Rx Loss Port4 0: NO 1: YES
1.3.6.1.4.1.4756.20.730.20.1.886Columnf2000EASPort4LLFLogicLocalread-writecurrentf2000EAS Series card Port4 link loss forwarding - Logic 0: AND 1: OR
1.3.6.1.4.1.4756.20.730.20.1.887Columnf2000EASPort4LLFLogicPort1Localread-writecurrentf2000EAS Series card Port4 link loss forwarding - Link/Rx Loss Port1 0: NO 1: YES
1.3.6.1.4.1.4756.20.730.20.1.888Columnf2000EASPort4LLFLogicPort2Localread-writecurrentf2000EAS Series card Port4 link loss forwarding - Link/Rx Loss Port2 0: NO 1: YES
1.3.6.1.4.1.4756.20.730.20.1.889Columnf2000EASPort4LLFLogicPort3Localread-writecurrentf2000EAS Series card Port4 link loss forwarding - Link/Rx Loss Port3 0: NO 1: YES
1.3.6.1.4.1.4756.20.730.20.1.890Columnf2000EASAddIPRouteLocalread-writecurrentf2000EAS Series card IP Routes: Add a new IP Routes : Syntax: [<Interface>] [<network>] [<mask_len>] [<gateway>] [<next_hop_vlan>] Interface : 1~4
1.3.6.1.4.1.4756.20.730.20.1.891Columnf2000EASDeleteIPRouteLocalread-writecurrentf2000EAS Series card IP Routes num: Delete a IP Routes num: Syntax: [<Interface>] Interface: 1~4
1.3.6.1.4.1.4756.20.730.20.1.892Columnf2000EASPort1RemotePowerStsLocalread-onlycurrentf2000EAS Series card Port1 remote Power status 0: None 1: OK 2: Abnormal
1.3.6.1.4.1.4756.20.730.20.1.893Columnf2000EASPort2RemotePowerStsLocalread-onlycurrentf2000EAS Series card Port2 remote Power status 0: None 1: OK 2: Abnormal
1.3.6.1.4.1.4756.20.730.20.1.894Columnf2000EASPort3RemotePowerStsLocalread-onlycurrentf2000EAS Series card Port3 remote Power status 0: None 1: OK 2: Abnormal
1.3.6.1.4.1.4756.20.730.20.1.895Columnf2000EASPort4RemotePowerStsLocalread-onlycurrentf2000EAS Series card Port4 remote Power status 0: None 1: OK 2: Abnormal
1.3.6.1.4.1.4756.20.730.20.1.896Columnf2000EASPort1LinkAlarmLocalread-writecurrentf2000EAS Series card Port 1 Link alarm: 0: Disable 1: Enable
1.3.6.1.4.1.4756.20.730.20.1.897Columnf2000EASPort2LinkAlarmLocalread-writecurrentf2000EAS Series card Port 2 Link alarm: 0: Disable 1: Enable
1.3.6.1.4.1.4756.20.730.20.1.898Columnf2000EASPort3LinkAlarmLocalread-writecurrentf2000EAS Series card Port 3 Link alarm: 0: Disable 1: Enable
1.3.6.1.4.1.4756.20.730.20.1.899Columnf2000EASPort4LinkAlarmLocalread-writecurrentf2000EAS Series card Port 4 Link alarm: 0: Disable 1: Enable
1.3.6.1.4.1.4756.20.730.20.1.900Columnf2000EASRemoteAHWResetLocalread-writecurrentf2000EAS Series card Remote A H/W Reset: 0: OFF 1: action
1.3.6.1.4.1.4756.20.730.20.1.901Columnf2000EASRemoteBHWResetLocalread-writecurrentf2000EAS Series card Remote B H/W Reset: 0: OFF 1: action
1.3.6.1.4.1.4756.20.730.20.1.902Columnf2000EASRemoteTLPTLocalread-writecurrentf2000EAS Series card Remote TLPT: 0: Disable 1: RemoteA 2: RemoteB
1.3.6.1.4.1.4756.20.731Nodef2000EASRemoteACards
1.3.6.1.4.1.4756.20.731.20Tablef2000EASRemoteATablenot-accessiblecurrentA list of RemoteA FRM220A-2000EAS series card entries.
1.3.6.1.4.1.4756.20.731.20.1Rowf2000EASRemoteAEntrynot-accessiblecurrentAn entry containing management information applicable to a particular FRM220A-2000EAS series card.
1.3.6.1.4.1.4756.20.731.20.1.1Columnf2000EASChassisIndexRemoteAread-onlycurrentA unique value for each card. It starts from 0 to 9 contiguously.
1.3.6.1.4.1.4756.20.731.20.1.2Columnf2000EASSlotIndexRemoteAread-onlycurrentA unique value for each card. It starts from 1 to 20 contiguously.
1.3.6.1.4.1.4756.20.731.20.1.3Columnf2000EASCardHWVerRemoteAread-onlycurrentf2000EAS Series card hardware version x.xxx
1.3.6.1.4.1.4756.20.731.20.1.4Columnf2000EASCardFWVerRemoteAread-onlycurrentf2000EAS Series card firmware version x.xxx
1.3.6.1.4.1.4756.20.731.20.1.5Columnf2000EASCardCPLDVerRemoteAread-onlycurrentf2000EAS Series card CPLD version x.xxx
1.3.6.1.4.1.4756.20.731.20.1.6Columnf2000EASCardFPGAVerRemoteAread-onlycurrentf2000EAS Series card FPGA version x.xxx
1.3.6.1.4.1.4756.20.731.20.1.7Columnf2000EASModelRemoteAread-onlycurrentCard Type: 0:2000EAS/4F 1:2000EAS/2F 2:2000EAS/1F
1.3.6.1.4.1.4756.20.731.20.1.8Columnf2000EASDNSServerTypeRemoteAread-writecurrentf2000EAS Series card IP Configuration: This setting controls the DNS name resolution done by the switch. The following modes are supported: 0:No DNS server No …
1.3.6.1.4.1.4756.20.731.20.1.9Columnf2000EASDNSServerSettingRemoteAread-writecurrentf2000EAS Series card IP Configuration: If iDNSServerType setting '3:Configured',this value must setting IP address format as below: Dotted Decimal Notation ref…
1.3.6.1.4.1.4756.20.731.20.1.10Columnf2000EASDNSproxyRemoteAread-writecurrentf2000EAS Series card IP Configuration: When DNS proxy is enabled, system will relay DNS requests to the currently configured DNS server, and reply as a DNS res…
1.3.6.1.4.1.4756.20.731.20.1.11Columnf2000EASAddIPV4InterfaceRemoteAread-writecurrentf2000EAS Series card IP Interfaces: Add a new IP VLAN Interface: Syntax: [<Interface>] [<vlan_list>] [<IPV4_Addr>] [<IPV4_MASK>] Interface : 1~4
1.3.6.1.4.1.4756.20.731.20.1.12Columnf2000EASDeleteInterfaceRemoteAread-writecurrentf2000EAS Series card IP Interfaces: Delete a IPv4/v6 VLAN Interface: Syntax: [<Interface>] Interface: 1~4
1.3.6.1.4.1.4756.20.731.20.1.13Columnf2000EASIPInterface1VLANRemoteAread-onlycurrentf2000EAS Series card IP Interfaces: The VLAN associated with the IP interface. Only ports in this VLAN will be able to access the IP interface. This field is o…
1.3.6.1.4.1.4756.20.731.20.1.14Columnf2000EASIPInterface1DHCPRemoteAread-writecurrentf2000EAS Series card IP Interfaces: DHCP
1.3.6.1.4.1.4756.20.731.20.1.15Columnf2000EASIPInterface1FallbackRemoteAread-writecurrentf2000EAS Series card IP Interfaces: Fallback
1.3.6.1.4.1.4756.20.731.20.1.16Columnf2000EASIPInterface1IPV4CurrentLeaseRemoteAread-onlycurrentf2000EAS Series card IP Interfaces: IPV4 Current Lease Address
1.3.6.1.4.1.4756.20.731.20.1.17Columnf2000EASIPInterface1IPV4AddressRemoteAread-onlycurrentf2000EAS Series card IP Interfaces: IPV4 Address
1.3.6.1.4.1.4756.20.731.20.1.18Columnf2000EASIPInterface1IPV4MASKLenRemoteAread-onlycurrentf2000EAS Series card IP Interfaces: IPV4 MASK Length
1.3.6.1.4.1.4756.20.731.20.1.19Columnf2000EASIPInterface2VLANRemoteAread-onlycurrentf2000EAS Series card IP Interfaces: The VLAN associated with the IP interface. Only ports in this VLAN will be able to access the IP interface. This field is o…
1.3.6.1.4.1.4756.20.731.20.1.20Columnf2000EASIPInterface2DHCPRemoteAread-writecurrentf2000EASEDD Series card IP Interfaces: DHCP
1.3.6.1.4.1.4756.20.731.20.1.21Columnf2000EASIPInterface2FallbackRemoteAread-writecurrentf2000EASEDD Series card IP Interfaces: Fallback
1.3.6.1.4.1.4756.20.731.20.1.22Columnf2000EASIPInterface2IPV4CurrentLeaseRemoteAread-onlycurrentf2000EAS Series card IP Interfaces: IPV4 Current Lease Address
1.3.6.1.4.1.4756.20.731.20.1.23Columnf2000EASIPInterface2IPV4AddressRemoteAread-onlycurrentf2000EAS Series card IP Interfaces: IPV4 Address
1.3.6.1.4.1.4756.20.731.20.1.24Columnf2000EASIPInterface2IPV4MASKLenRemoteAread-onlycurrentf2000EAS Series card IP Interfaces: IPV4 MASK Length
1.3.6.1.4.1.4756.20.731.20.1.25Columnf2000EASIPInterface3VLANRemoteAread-onlycurrentf2000EAS Series card IP Interfaces: The VLAN associated with the IP interface. Only ports in this VLAN will be able to access the IP interface. This field is o…
1.3.6.1.4.1.4756.20.731.20.1.26Columnf2000EASIPInterface3DHCPRemoteAread-writecurrentf2000EAS Series card IP Interfaces: DHCP
1.3.6.1.4.1.4756.20.731.20.1.27Columnf2000EASIPInterface3FallbackRemoteAread-writecurrentf2000EAS Series card IP Interfaces: Fallback
1.3.6.1.4.1.4756.20.731.20.1.28Columnf2000EASIPInterface3IPV4CurrentLeaseRemoteAread-onlycurrentf2000EAS Series card IP Interfaces: IPV4 Current Lease Address
1.3.6.1.4.1.4756.20.731.20.1.29Columnf2000EASIPInterface3IPV4AddressRemoteAread-onlycurrentf2000EAS Series card IP Interfaces: IPV4 Address
1.3.6.1.4.1.4756.20.731.20.1.30Columnf2000EASIPInterface3IPV4MASKLenRemoteAread-onlycurrentf2000EAS Series card IP Interfaces: IPV4 MASK Length
1.3.6.1.4.1.4756.20.731.20.1.31Columnf2000EASIPInterface4VLANRemoteAread-onlycurrentf2000EAS Series card IP Interfaces: The VLAN associated with the IP interface. Only ports in this VLAN will be able to access the IP interface. This field is o…
1.3.6.1.4.1.4756.20.731.20.1.32Columnf2000EASIPInterface4DHCPRemoteAread-writecurrentf2000EAS Series card IP Interfaces: DHCP
1.3.6.1.4.1.4756.20.731.20.1.33Columnf2000EASIPInterface4FallbackRemoteAread-writecurrentf2000EAS Series card IP Interfaces: Fallback
1.3.6.1.4.1.4756.20.731.20.1.34Columnf2000EASIPInterface4IPV4CurrentLeaseRemoteAread-onlycurrentf2000EAS Series card IP Interfaces: IPV4 Current Lease Address
1.3.6.1.4.1.4756.20.731.20.1.35Columnf2000EASIPInterface4IPV4AddressRemoteAread-onlycurrentf2000EAS Series card IP Interfaces: IPV4 Address
1.3.6.1.4.1.4756.20.731.20.1.36Columnf2000EASIPInterface4IPV4MASKLenRemoteAread-onlycurrentf2000EAS Series card IP Interfaces: IPV4 MASK Length
1.3.6.1.4.1.4756.20.731.20.1.37Columnf2000EASAddIPV6InterfaceRemoteAread-writecurrentf2000EAS Series card IP Interfaces: Add a new IPv6 VLAN Interface: Syntax: [<Interface>] [<vlan_list>] [<IPV4_Addr>] [<IPV4_MASK>] Interface : 1~4
1.3.6.1.4.1.4756.20.731.20.1.38Columnf2000EASIPInterface1IPV6DHCPRemoteAread-writecurrentf2000EAS Series card IP Interfaces: IPV6 DHCP
1.3.6.1.4.1.4756.20.731.20.1.39Columnf2000EASIPInterface1IPV6RapidCommitRemoteAread-writecurrentf2000EAS Series card IP Interfaces1: IPV6 RapidCommit
1.3.6.1.4.1.4756.20.731.20.1.40Columnf2000EASIPInterface1IPV6CurrentLeaseRemoteAread-onlycurrentf2000EAS Series card IP Interfaces: IPV6 Current lease Address
1.3.6.1.4.1.4756.20.731.20.1.41Columnf2000EASIPInterface1IPV6AddressRemoteAread-onlycurrentf2000EAS Series card IP Interfaces: IPV6 Address
1.3.6.1.4.1.4756.20.731.20.1.42Columnf2000EASIPInterface1IPV6MASKLenRemoteAread-onlycurrentf2000EAS Series card IP Interfaces: IPV6 MASK Length
1.3.6.1.4.1.4756.20.731.20.1.43Columnf2000EASIPInterface2IPV6DHCPRemoteAread-writecurrentf2000EAS Series card IP Interfaces2: IPV6 DHCP
1.3.6.1.4.1.4756.20.731.20.1.44Columnf2000EASIPInterface2IPV6RapidCommitRemoteAread-writecurrentf2000EAS Series card IP Interfaces2: IPV6 RapidCommit
1.3.6.1.4.1.4756.20.731.20.1.45Columnf2000EASIPInterface2IPV6CurrentLeaseRemoteAread-onlycurrentf2000EAS Series card IP Interfaces: IPV6 Current lease Address
1.3.6.1.4.1.4756.20.731.20.1.46Columnf2000EASIPInterface2IPV6AddressRemoteAread-onlycurrentf2000EAS Series card IP Interfaces: IPV6 Address
1.3.6.1.4.1.4756.20.731.20.1.47Columnf2000EASIPInterface2IPV6MASKLenRemoteAread-onlycurrentf2000EAS Series card IP Interfaces: IPV6 MASK Length
1.3.6.1.4.1.4756.20.731.20.1.48Columnf2000EASIPInterface3IPV6DHCPRemoteAread-writecurrentf2000EAS Series card IP Interfaces2: IPV6 DHCP
1.3.6.1.4.1.4756.20.731.20.1.49Columnf2000EASIPInterface3IPV6RapidCommitRemoteAread-writecurrentf2000EAS Series card IP Interfaces3: IPV6 RapidCommit
1.3.6.1.4.1.4756.20.731.20.1.50Columnf2000EASIPInterface3IPV6CurrentLeaseRemoteAread-onlycurrentf2000EAS Series card IP Interfaces: IPV6 Current lease Address
1.3.6.1.4.1.4756.20.731.20.1.51Columnf2000EASIPInterface3IPV6AddressRemoteAread-onlycurrentf2000EAS Series card IP Interfaces3: IPV6 Address
1.3.6.1.4.1.4756.20.731.20.1.52Columnf2000EASIPInterface3IPV6MASKLenRemoteAread-onlycurrentf2000EAS Series card IP Interfaces: IPV6 MASK Length
1.3.6.1.4.1.4756.20.731.20.1.53Columnf2000EASIPInterface4IPV6DHCPRemoteAread-writecurrentf2000EAS Series card IP Interfaces4: IPV6 DHCP
1.3.6.1.4.1.4756.20.731.20.1.54Columnf2000EASIPInterface4IPV6RapidCommitRemoteAread-writecurrentf2000EAS Series card IP Interfaces4: IPV6 RapidCommit
1.3.6.1.4.1.4756.20.731.20.1.55Columnf2000EASIPInterface4IPV6CurrentLeaseRemoteAread-onlycurrentf2000EAS Series card IP Interfaces: IPV6 Current lease Address
1.3.6.1.4.1.4756.20.731.20.1.56Columnf2000EASIPInterface4IPV6AddressRemoteAread-onlycurrentf2000EAS Series card IP Interfaces: IPV6 Address
1.3.6.1.4.1.4756.20.731.20.1.57Columnf2000EASIPInterface4IPV6MASKLenRemoteAread-onlycurrentf2000EAS Series card IP Interfaces: IPV6 MASK Length
1.3.6.1.4.1.4756.20.731.20.1.58Columnf2000EASIPRoutes1NetworkRemoteAread-onlycurrentf2000EAS Series card IP Routes: NetWork
1.3.6.1.4.1.4756.20.731.20.1.59Columnf2000EASIPRoutes1MASKLenRemoteAread-onlycurrentf2000EAS Series card IP Routes: MASK Length
1.3.6.1.4.1.4756.20.731.20.1.60Columnf2000EASIPRoutes1GetwayRemoteAread-onlycurrentf2000EAS Series card IP Routes: Getway
1.3.6.1.4.1.4756.20.731.20.1.61Columnf2000EASIPRoutes1HopVLANRemoteAread-onlycurrentf2000EAS Series card IP Routes: The VLAN associated with the IP Routes. Only ports in this VLAN will be able to access the IP Routes.
1.3.6.1.4.1.4756.20.731.20.1.62Columnf2000EASIPRoutes2NetworkRemoteAread-onlycurrentf2000EAS Series card IP Routes: NetWork
1.3.6.1.4.1.4756.20.731.20.1.63Columnf2000EASIPRoutes2MASKLenRemoteAread-onlycurrentf2000EAS Series card IP Routes: MASK Length
1.3.6.1.4.1.4756.20.731.20.1.64Columnf2000EASIPRoutes2GetwayRemoteAread-onlycurrentf2000EAS Series card IP Routes: Getway
1.3.6.1.4.1.4756.20.731.20.1.65Columnf2000EASIPRoutes2HopVLANRemoteAread-onlycurrentf2000EAS Series card IP Routes: The VLAN associated with the IP Routes. Only ports in this VLAN will be able to access the IP Routes.
1.3.6.1.4.1.4756.20.731.20.1.66Columnf2000EASIPRoutes3NetworkRemoteAread-onlycurrentf2000EAS Series card IP Routes: NetWork
1.3.6.1.4.1.4756.20.731.20.1.67Columnf2000EASIPRoutes3MASKLenRemoteAread-onlycurrentf2000EAS Series card IP Routes: MASK Length
1.3.6.1.4.1.4756.20.731.20.1.68Columnf2000EASIPRoutes3GetwayRemoteAread-onlycurrentf2000EAS Series card IP Routes: Getway
1.3.6.1.4.1.4756.20.731.20.1.69Columnf2000EASIPRoutes3HopVLANRemoteAread-onlycurrentf2000EAS Series card IP Routes: The VLAN associated with the IP Routes. Only ports in this VLAN will be able to access the IP Routes.
1.3.6.1.4.1.4756.20.731.20.1.70Columnf2000EASIPRoutes4NetworkRemoteAread-onlycurrentf2000EAS Series card IP Routes: NetWork
1.3.6.1.4.1.4756.20.731.20.1.71Columnf2000EASIPRoutes4MASKLenRemoteAread-onlycurrentf2000EAS Series card IP Routes: MASK Length
1.3.6.1.4.1.4756.20.731.20.1.72Columnf2000EASIPRoutes4GetwayRemoteAread-onlycurrentf2000EAS Series card IP Routes: Getway
1.3.6.1.4.1.4756.20.731.20.1.73Columnf2000EASIPRoutes4HopVLANRemoteAread-onlycurrentf2000EAS Series card IP Routes: The VLAN associated with the IP Routes. Only ports in this VLAN will be able to access the IP Routes.
1.3.6.1.4.1.4756.20.731.20.1.74Columnf2000EASPort1LinkstsRemoteAread-onlycurrentf2000EAS Series card Port1 link status: 0:Link down 1:Link up
1.3.6.1.4.1.4756.20.731.20.1.75Columnf2000EASPort1SpeedstsRemoteAread-onlycurrentf2000EAS Series card Port1 speed status
1.3.6.1.4.1.4756.20.731.20.1.76Columnf2000EASPort1DuplexstsRemoteAread-onlycurrentf2000EAS Series card Port1 duplex status 0: Half 1: Full
1.3.6.1.4.1.4756.20.731.20.1.77Columnf2000EASPort1RxPausestsRemoteAread-onlycurrentf2000EAS Series card Port1 rx pause status 0: No 1: Yes
1.3.6.1.4.1.4756.20.731.20.1.78Columnf2000EASPort1TxPausestsRemoteAread-onlycurrentf2000EAS Series card Port1 tx pause status 0: No 1: Yes
1.3.6.1.4.1.4756.20.731.20.1.79Columnf2000EASPort2LinkstsRemoteAread-onlycurrentf2000EAS Series card Port2 link status: 0:Link down 1:Link up
1.3.6.1.4.1.4756.20.731.20.1.80Columnf2000EASPort2SpeedstsRemoteAread-onlycurrentf2000EAS Series card Port2 speed status
1.3.6.1.4.1.4756.20.731.20.1.81Columnf2000EASPort2DuplexstsRemoteAread-onlycurrentf2000EAS Series card Port2 duplex status 0: Half 1: Full
1.3.6.1.4.1.4756.20.731.20.1.82Columnf2000EASPort2RxPausestsRemoteAread-onlycurrentf2000EAS Series card Port2 rx pause status 0: No 1: Yes
1.3.6.1.4.1.4756.20.731.20.1.83Columnf2000EASPort2TxPausestsRemoteAread-onlycurrentf2000EAS Series card Port2 tx pause status 0: No 1: Yes
1.3.6.1.4.1.4756.20.731.20.1.84Columnf2000EASPort3LinkstsRemoteAread-onlycurrentf2000EAS Series card Port3 link status: 0:Link down 1:Link up
1.3.6.1.4.1.4756.20.731.20.1.85Columnf2000EASPort3SpeedstsRemoteAread-onlycurrentf2000EAS Series card Port3 speed status
1.3.6.1.4.1.4756.20.731.20.1.86Columnf2000EASPort3DuplexstsRemoteAread-onlycurrentf2000EAS Series card Port3 duplex status 0: Half 1: Full
1.3.6.1.4.1.4756.20.731.20.1.87Columnf2000EASPort3RxPausestsRemoteAread-onlycurrentf2000EAS Series card Port3 rx pause status 0: No 1: Yes
1.3.6.1.4.1.4756.20.731.20.1.88Columnf2000EASPort3TxPausestsRemoteAread-onlycurrentf2000EAS Series card Port3 tx pause status 0: No 1: Yes
1.3.6.1.4.1.4756.20.731.20.1.89Columnf2000EASPort4LinkstsRemoteAread-onlycurrentf2000EAS Series card Port4 link status: 0:Link down 1:Link up
1.3.6.1.4.1.4756.20.731.20.1.90Columnf2000EASPort4SpeedstsRemoteAread-onlycurrentf2000EAS Series card Port4 speed status
1.3.6.1.4.1.4756.20.731.20.1.91Columnf2000EASPort4DuplexstsRemoteAread-onlycurrentf2000EAS Series card Port4 duplex status 0: Half 1: Full
1.3.6.1.4.1.4756.20.731.20.1.92Columnf2000EASPort4RxPausestsRemoteAread-onlycurrentf2000EAS Series card Port4 rx pause status 0: No 1: Yes
1.3.6.1.4.1.4756.20.731.20.1.93Columnf2000EASPort4TxPausestsRemoteAread-onlycurrentf2000EAS Series card Port4 tx pause status 0: No 1: Yes
1.3.6.1.4.1.4756.20.731.20.1.94Columnf2000EASPort1SpeedConfRemoteAread-writecurrentf2000EAS Series card Port1 speed config 0: disable 1: auto 2: 100M FDX 3: 1G FDX
1.3.6.1.4.1.4756.20.731.20.1.95Columnf2000EASPort1flowConrolRemoteAread-writecurrentf2000EAS Series card Port1 flow control config 0: no 1: yes
1.3.6.1.4.1.4756.20.731.20.1.96Columnf2000EASPort1MaxFrameRemoteAread-writecurrentf2000EAS Series card Port1 max frame config
1.3.6.1.4.1.4756.20.731.20.1.97Columnf2000EASPort1ALSRemoteAread-writecurrentf2000EAS Series card Port1 auto laser shutdown: 0: Disable 1: Enable
1.3.6.1.4.1.4756.20.731.20.1.98Columnf2000EASPort1FrameLengthCheckRemoteAread-writecurrentf2000EAS Series card Port1 Frame Length Check config 0: no 1: yes
1.3.6.1.4.1.4756.20.731.20.1.99Columnf2000EASPort2SpeedConfRemoteAread-writecurrentf2000EAS Series card Port2 speed config 0: disable 1: auto 2: 100M FDX 3: 1G FDX
1.3.6.1.4.1.4756.20.731.20.1.100Columnf2000EASPort2flowConrolRemoteAread-writecurrentf2000EAS Series card Port2 flow control config 0: no 1: yes
1.3.6.1.4.1.4756.20.731.20.1.101Columnf2000EASPort2MaxFrameRemoteAread-writecurrentf2000EAS Series card Port2 max frame config
1.3.6.1.4.1.4756.20.731.20.1.102Columnf2000EASPort2ALSRemoteAread-writecurrentf2000EAS Series card Port2 auto laser shutdown: 0: Disable 1: Enable
1.3.6.1.4.1.4756.20.731.20.1.103Columnf2000EASPort2FrameLengthCheckRemoteAread-writecurrentf2000EAS Series card Port2 Frame Length Check config 0: no 1: yes
1.3.6.1.4.1.4756.20.731.20.1.104Columnf2000EASPort3SpeedConfRemoteAread-writecurrentf2000EAS Series card Port3 speed config 0: disable 1: auto 2: 10M HDX 3: 10M FDX 4: 100M HDX 5: 100M FDX 6: 1G FDX
1.3.6.1.4.1.4756.20.731.20.1.105Columnf2000EASPort3flowConrolRemoteAread-writecurrentf2000EAS Series card Port3 flow control config 0: no 1: yes
1.3.6.1.4.1.4756.20.731.20.1.106Columnf2000EASPort3MaxFrameRemoteAread-writecurrentf2000EAS Series card Port3 max frame config
1.3.6.1.4.1.4756.20.731.20.1.107Columnf2000EASPort3CollisionModeRemoteAread-writecurrentf2000EAS Series card Port3 collision mode config. 0: Discard 1: Restart
1.3.6.1.4.1.4756.20.731.20.1.108Columnf2000EASPort3ALSRemoteAread-writecurrentf2000EAS Series card Port3 auto laser shutdown 0: Disable 1: Enable
1.3.6.1.4.1.4756.20.731.20.1.109Columnf2000EASPort3FrameLengthCheckRemoteAread-writecurrentf2000EAS Series card Port3 Frame Length Check config 0: no 1: yes
1.3.6.1.4.1.4756.20.731.20.1.110Columnf2000EASPort4SpeedConfRemoteAread-writecurrentf2000EAS Series card Port4 speed config 0: disable 1: auto 2: 10M HDX 3: 10M FDX 4: 100M HDX 5: 100M FDX 6: 1G FDX
1.3.6.1.4.1.4756.20.731.20.1.111Columnf2000EASPort4flowConrolRemoteAread-writecurrentf2000EAS Series card Port4 flow control config 0: no 1: yes
1.3.6.1.4.1.4756.20.731.20.1.112Columnf2000EASPort4MaxFrameRemoteAread-writecurrentf2000EAS Series card Port4 max frame config
1.3.6.1.4.1.4756.20.731.20.1.113Columnf2000EASPort4CollisionModeRemoteAread-writecurrentf2000EAS Series card Port4 collision mode config 0: Discard 1: Restart
1.3.6.1.4.1.4756.20.731.20.1.114Columnf2000EASPort4ALSRemoteAread-writecurrentf2000EAS Series card Port4 auto laser shutdown 0: Disable 1: Enable
1.3.6.1.4.1.4756.20.731.20.1.115Columnf2000EASPort4FrameLengthCheckRemoteAread-writecurrentf2000EAS Series card Port4 Frame Length Check config 0: no 1: yes
1.3.6.1.4.1.4756.20.731.20.1.116Columnf2000EASPort1AdvDuplexHdxRemoteAread-writecurrentf2000EAS Series card Port1 Adv Dpulex Hdx 0: OFF 1: ON
1.3.6.1.4.1.4756.20.731.20.1.117Columnf2000EASPort1AdvDuplexFdxRemoteAread-writecurrentf2000EAS Series card Port1 Adv Dpulex Fdx 0: OFF 1: ON
1.3.6.1.4.1.4756.20.731.20.1.118Columnf2000EASPort1AdvSpeed10MRemoteAread-writecurrentf2000EAS Series card Port1 Adv Speed 10M 0: OFF 1: ON
1.3.6.1.4.1.4756.20.731.20.1.119Columnf2000EASPort1AdvSpeed100MRemoteAread-writecurrentf2000EAS Series card Port1 Adv Speed 100M 0: OFF 1: ON
1.3.6.1.4.1.4756.20.731.20.1.120Columnf2000EASPort1AdvSpeed1GRemoteAread-writecurrentf2000EAS Series card Port1 Adv Speed 1G 0: OFF 1: ON
1.3.6.1.4.1.4756.20.731.20.1.121Columnf2000EASPort2AdvDuplexHdxRemoteAread-writecurrentf2000EAS Series card Port2 Adv Dpulex Hdx 0: OFF 1: ON
1.3.6.1.4.1.4756.20.731.20.1.122Columnf2000EASPort2AdvDuplexFdxRemoteAread-writecurrentf2000EAS Series card Port2 Adv Dpulex Fdx 0: OFF 1: ON
1.3.6.1.4.1.4756.20.731.20.1.123Columnf2000EASPort2AdvSpeed10MRemoteAread-writecurrentf2000EAS Series card Port2 Adv Speed 10M 0: OFF 1: ON
1.3.6.1.4.1.4756.20.731.20.1.124Columnf2000EASPort2AdvSpeed100MRemoteAread-writecurrentf2000EAS Series card Port2 Adv Speed 100M 0: OFF 1: ON
1.3.6.1.4.1.4756.20.731.20.1.125Columnf2000EASPort2AdvSpeed1GRemoteAread-writecurrentf2000EAS Series card Port2 Adv Speed 1G 0: OFF 1: ON
1.3.6.1.4.1.4756.20.731.20.1.126Columnf2000EASPort3AdvDuplexHdxRemoteAread-writecurrentf2000EAS Series card Port3 Adv Dpulex Hdx 0: OFF 1: ON
1.3.6.1.4.1.4756.20.731.20.1.127Columnf2000EASPort3AdvDuplexFdxRemoteAread-writecurrentf2000EAS Series card Port3 Adv Dpulex Fdx 0: OFF 1: ON
1.3.6.1.4.1.4756.20.731.20.1.128Columnf2000EASPort3AdvSpeed10MRemoteAread-writecurrentf2000EAS Series card Port3 Adv Speed 10M 0: OFF 1: ON
1.3.6.1.4.1.4756.20.731.20.1.129Columnf2000EASPort3AdvSpeed100MRemoteAread-writecurrentf2000EAS Series card Port3 Adv Speed 100M 0: OFF 1: ON
1.3.6.1.4.1.4756.20.731.20.1.130Columnf2000EASPort3AdvSpeed1GRemoteAread-writecurrentf2000EAS Series card Port3 Adv Speed 1G 0: OFF 1: ON
1.3.6.1.4.1.4756.20.731.20.1.131Columnf2000EASPort4AdvDuplexHdxRemoteAread-writecurrentf2000EAS Series card Port4 Adv Dpulex Hdx 0: OFF 1: ON
1.3.6.1.4.1.4756.20.731.20.1.132Columnf2000EASPort4AdvDuplexFdxRemoteAread-writecurrentf2000EAS Series card Port4 Adv Dpulex Fdx 0: OFF 1: ON
1.3.6.1.4.1.4756.20.731.20.1.133Columnf2000EASPort4AdvSpeed10MRemoteAread-writecurrentf2000EAS Series card Port4 Adv Speed 10M 0: OFF 1: ON
1.3.6.1.4.1.4756.20.731.20.1.134Columnf2000EASPort4AdvSpeed100MRemoteAread-writecurrentf2000EAS Series card Port4 Adv Speed 100M 0: OFF 1: ON
1.3.6.1.4.1.4756.20.731.20.1.135Columnf2000EASPort4AdvSpeed1GRemoteAread-writecurrentf2000EAS Series card Port4 Adv Speed 1G 0: OFF 1: ON
1.3.6.1.4.1.4756.20.731.20.1.136Columnf2000EASPortResetRemoteAread-writecurrentf2000EAS Series card port reset 0: OFF 1: Action
1.3.6.1.4.1.4756.20.731.20.1.137Columnf2000EASSetDefaultRemoteAread-writecurrentf2000EAS Series card set to default config 0: OFF 1: Action
1.3.6.1.4.1.4756.20.731.20.1.138Columnf2000EASPort1PacketsRxRemoteAread-onlycurrentf2000EAS Series card port1 traffic overview:: Packets Rx
1.3.6.1.4.1.4756.20.731.20.1.139Columnf2000EASPort1PacketsTxRemoteAread-onlycurrentf2000EAS Series card port1 traffic overview:: Packets Tx
1.3.6.1.4.1.4756.20.731.20.1.140Columnf2000EASPort1BytesRxRemoteAread-onlycurrentf2000EAS Series card port1 traffic overview:: Bytes Rx
1.3.6.1.4.1.4756.20.731.20.1.141Columnf2000EASPort1BytesTxRemoteAread-onlycurrentf2000EAS Series card port1 traffic overview:: Bytes Tx
1.3.6.1.4.1.4756.20.731.20.1.142Columnf2000EASPort1ErrorsRxRemoteAread-onlycurrentf2000EAS Series card port1 traffic overview:: Errors Rx
1.3.6.1.4.1.4756.20.731.20.1.143Columnf2000EASPort1ErrorsTxRemoteAread-onlycurrentf2000EAS Series card port1 traffic overview:: Errors Tx
1.3.6.1.4.1.4756.20.731.20.1.144Columnf2000EASPort1DropsRxRemoteAread-onlycurrentf2000EAS Series card port1 traffic overview:: Drops Rx
1.3.6.1.4.1.4756.20.731.20.1.145Columnf2000EASPort1DropsTxRemoteAread-onlycurrentf2000EAS Series card port1 traffic overview:: Drops Tx
1.3.6.1.4.1.4756.20.731.20.1.146Columnf2000EASPort1FilteredRxRemoteAread-onlycurrentf2000EAS Series card port1 traffic overview:: Filtered Rx
1.3.6.1.4.1.4756.20.731.20.1.147Columnf2000EASPort2PacketsRxRemoteAread-onlycurrentf2000EAS Series card port2 traffic overview:: Packets Rx
1.3.6.1.4.1.4756.20.731.20.1.148Columnf2000EASPort2PacketsTxRemoteAread-onlycurrentf2000EAS Series card port2 traffic overview:: Packets Tx
1.3.6.1.4.1.4756.20.731.20.1.149Columnf2000EASPort2BytesRxRemoteAread-onlycurrentf2000EAS Series card port2 traffic overview:: Bytes Rx
1.3.6.1.4.1.4756.20.731.20.1.150Columnf2000EASPort2BytesTxRemoteAread-onlycurrentf2000EAS Series card port2 traffic overview:: Bytes Tx
1.3.6.1.4.1.4756.20.731.20.1.151Columnf2000EASPort2ErrorsRxRemoteAread-onlycurrentf2000EAS Series card port2 traffic overview:: Errors Rx
1.3.6.1.4.1.4756.20.731.20.1.152Columnf2000EASPort2ErrorsTxRemoteAread-onlycurrentf2000EAS Series card port2 traffic overview:: Errors Tx
1.3.6.1.4.1.4756.20.731.20.1.153Columnf2000EASPort2DropsRxRemoteAread-onlycurrentf2000EAS Series card port2 traffic overview:: Drops Rx
1.3.6.1.4.1.4756.20.731.20.1.154Columnf2000EASPort2DropsTxRemoteAread-onlycurrentf2000EAS Series card port2 traffic overview:: Drops Tx
1.3.6.1.4.1.4756.20.731.20.1.155Columnf2000EASPort2FilteredRxRemoteAread-onlycurrentf2000EAS Series card port2 traffic overview:: Filtered Rx
1.3.6.1.4.1.4756.20.731.20.1.156Columnf2000EASPort3PacketsRxRemoteAread-onlycurrentf2000EAS Series card port3 traffic overview:: Packets Rx
1.3.6.1.4.1.4756.20.731.20.1.157Columnf2000EASPort3PacketsTxRemoteAread-onlycurrentf2000EAS Series card port3 traffic overview:: Packets Tx
1.3.6.1.4.1.4756.20.731.20.1.158Columnf2000EASPort3BytesRxRemoteAread-onlycurrentf2000EAS Series card port3 traffic overview:: Bytes Rx
1.3.6.1.4.1.4756.20.731.20.1.159Columnf2000EASPort3BytesTxRemoteAread-onlycurrentf2000EAS Series card port3 traffic overview:: Bytes Tx
1.3.6.1.4.1.4756.20.731.20.1.160Columnf2000EASPort3ErrorsRxRemoteAread-onlycurrentf2000EAS Series card port3 traffic overview:: Errors Rx
1.3.6.1.4.1.4756.20.731.20.1.161Columnf2000EASPort3ErrorsTxRemoteAread-onlycurrentf2000EAS Series card port3 traffic overview:: Errors Tx
1.3.6.1.4.1.4756.20.731.20.1.162Columnf2000EASPort3DropsRxRemoteAread-onlycurrentf2000EAS Series card port3 traffic overview:: Drops Rx
1.3.6.1.4.1.4756.20.731.20.1.163Columnf2000EASPort3DropsTxRemoteAread-onlycurrentf2000EAS Series card port3 traffic overview:: Drops Tx
1.3.6.1.4.1.4756.20.731.20.1.164Columnf2000EASPort3FilteredRxRemoteAread-onlycurrentf2000EAS Series card port3 traffic overview:: Filtered Rx
1.3.6.1.4.1.4756.20.731.20.1.165Columnf2000EASPort4PacketsRxRemoteAread-onlycurrentf2000EAS Series card port4 traffic overview:: Packets Rx
1.3.6.1.4.1.4756.20.731.20.1.166Columnf2000EASPort4PacketsTxRemoteAread-onlycurrentf2000EAS Series card port4 traffic overview:: Packets Tx
1.3.6.1.4.1.4756.20.731.20.1.167Columnf2000EASPort4BytesRxRemoteAread-onlycurrentf2000EAS Series card port4 traffic overview:: Bytes Rx
1.3.6.1.4.1.4756.20.731.20.1.168Columnf2000EASPort4BytesTxRemoteAread-onlycurrentf2000EAS Series card port4 traffic overview:: Bytes Tx
1.3.6.1.4.1.4756.20.731.20.1.169Columnf2000EASPort4ErrorsRxRemoteAread-onlycurrentf2000EAS Series card port4 traffic overview:: Errors Rx
1.3.6.1.4.1.4756.20.731.20.1.170Columnf2000EASPort4ErrorsTxRemoteAread-onlycurrentf2000EAS Series card port4 traffic overview:: Errors Tx
1.3.6.1.4.1.4756.20.731.20.1.171Columnf2000EASPort4DropsRxRemoteAread-onlycurrentf2000EAS Series card port4 traffic overview:: Drops Rx
1.3.6.1.4.1.4756.20.731.20.1.172Columnf2000EASPort4DropsTxRemoteAread-onlycurrentf2000EAS Series card port4 traffic overview:: Drops Tx
1.3.6.1.4.1.4756.20.731.20.1.173Columnf2000EASPort4FilteredRxRemoteAread-onlycurrentf2000EAS Series card port4 traffic overview:: Filtered Rx
1.3.6.1.4.1.4756.20.731.20.1.174Columnf2000EASDeviceActiveRemoteAread-onlycurrentf2000EAS Series card device active 0: Disable 1: Enable
1.3.6.1.4.1.4756.20.731.20.1.175Columnf2000EASFx1DDRemoteAread-onlycurrentf2000EAS Series card fiber1 port Digital Diagnostic function: 0:No 1:Yes
1.3.6.1.4.1.4756.20.731.20.1.176Columnf2000EASFx1DDVendorRemoteAread-onlycurrentf2000EAS Series card fiber1 port D/D information: Vendor name
1.3.6.1.4.1.4756.20.731.20.1.177Columnf2000EASFx1DDPartNoRemoteAread-onlycurrentf2000EAS Series card fiber1 port D/D information: Vendor part number
1.3.6.1.4.1.4756.20.731.20.1.178Columnf2000EASFx1DDFiberTypeRemoteAread-onlycurrentf2000EAS Series card fiber1 port D/D information: Fiber Type
1.3.6.1.4.1.4756.20.731.20.1.179Columnf2000EASFx1DDWaveLenRemoteAread-onlycurrentf2000EAS Series card fiber1 port D/D information: Wave length
1.3.6.1.4.1.4756.20.731.20.1.180Columnf2000EASFx1DDWaveLen2RemoteAread-onlycurrentf2000EAS Series card fiber1 port D/D information: Wave length 2
1.3.6.1.4.1.4756.20.731.20.1.181Columnf2000EASFx1DDLinkLenRemoteAread-onlycurrentf2000EAS Series card fiber1 port D/D information: Link length
1.3.6.1.4.1.4756.20.731.20.1.182Columnf2000EASFx1DDLenUnitRemoteAread-onlycurrentf2000EAS Series card fiber1 port D/D information: Length Unit
1.3.6.1.4.1.4756.20.731.20.1.183Columnf2000EASFx1DDStatusRemoteAread-onlycurrentf2000EAS Series card fiber1 port D/D information: Status Support
1.3.6.1.4.1.4756.20.731.20.1.184Columnf2000EASFx1DDRxSensRemoteAread-onlycurrentf2000EAS Series card fiber1 port D/D information: Rx Sensitivity
1.3.6.1.4.1.4756.20.731.20.1.185Columnf2000EASFx1DDTxPWRRemoteAread-onlycurrentf2000EAS Series card fiber1 port D/D information: Tx power
1.3.6.1.4.1.4756.20.731.20.1.186Columnf2000EASFx1DDRxPWRRemoteAread-onlycurrentf2000EAS Series card fiber1 port D/D information: Rx power
1.3.6.1.4.1.4756.20.731.20.1.187Columnf2000EASFx1DDTempRemoteAread-onlycurrentf2000EAS Series card fiber1 port D/D information: Temperature in degree C
1.3.6.1.4.1.4756.20.731.20.1.188Columnf2000EASFx1DDPWRMarginRemoteAread-onlycurrentf2000EAS Series card fiber1 port D/D information: Power margin
1.3.6.1.4.1.4756.20.731.20.1.189Columnf2000EASFx1DDPWRLossRemoteAread-onlycurrentf2000EAS Series card fiber1 port D/D information: Power loss
1.3.6.1.4.1.4756.20.731.20.1.190Columnf2000EASFx2DDRemoteAread-onlycurrentf2000EAS Series card fiber2 Digital Diagnostic function: 0:NO 1:Yes
1.3.6.1.4.1.4756.20.731.20.1.191Columnf2000EASFx2DDVendorRemoteAread-onlycurrentf2000EAS Series card fiber2 D/D information: Vendor name
1.3.6.1.4.1.4756.20.731.20.1.192Columnf2000EASFx2DDPartNoRemoteAread-onlycurrentf2000EAS Series card fiber2 D/D information: Vendor part number
1.3.6.1.4.1.4756.20.731.20.1.193Columnf2000EASFx2DDFiberTypeRemoteAread-onlycurrentf2000EAS Series card fiber2 D/D information: Fiber Type
1.3.6.1.4.1.4756.20.731.20.1.194Columnf2000EASFx2DDWaveLenRemoteAread-onlycurrentf2000EAS Series card fiber2 D/D information: Wave length 1
1.3.6.1.4.1.4756.20.731.20.1.195Columnf2000EASFx2DDWaveLen2RemoteAread-onlycurrentf2000EAS Series card fiber2 D/D information: Wave length 2
1.3.6.1.4.1.4756.20.731.20.1.196Columnf2000EASFx2DDLinkLenRemoteAread-onlycurrentf2000EAS Series card fiber2 D/D information: Link length
1.3.6.1.4.1.4756.20.731.20.1.197Columnf2000EASFx2DDLenUnitRemoteAread-onlycurrentf2000EAS Series card fiber2 D/D information: Length Unit
1.3.6.1.4.1.4756.20.731.20.1.198Columnf2000EASFx2DDStatusRemoteAread-onlycurrentf2000EAS Series card fiber2 D/D information: Status Support
1.3.6.1.4.1.4756.20.731.20.1.199Columnf2000EASFx2DDRxSensRemoteAread-onlycurrentf2000EAS Series card fiber2 D/D information: Rx Sensitivity
1.3.6.1.4.1.4756.20.731.20.1.200Columnf2000EASFx2DDTxPWRRemoteAread-onlycurrentf2000EAS Series card fiber2 D/D information: Tx power
1.3.6.1.4.1.4756.20.731.20.1.201Columnf2000EASFx2DDRxPWRRemoteAread-onlycurrentf2000EAS Series card fiber2 D/D information: Rx power
1.3.6.1.4.1.4756.20.731.20.1.202Columnf2000EASFx2DDTempRemoteAread-onlycurrentf2000EAS Series card fiber2 D/D information: Temperature in degree C
1.3.6.1.4.1.4756.20.731.20.1.203Columnf2000EASFx2DDPWRMarginRemoteAread-onlycurrentf2000EAS Series card fiber2 D/D information: Power margin
1.3.6.1.4.1.4756.20.731.20.1.204Columnf2000EASFx2DDPWRLossRemoteAread-onlycurrentf2000EAS Series card fiber2 D/D information: Power loss
1.3.6.1.4.1.4756.20.731.20.1.205Columnf2000EASFx3DDRemoteAread-onlycurrentf2000EAS Series card fiber3 Digital Diagnostic function: 0:NO 1:Yes
1.3.6.1.4.1.4756.20.731.20.1.206Columnf2000EASFx3DDVendorRemoteAread-onlycurrentf2000EAS Series card fiber3 D/D information: Vendor name
1.3.6.1.4.1.4756.20.731.20.1.207Columnf2000EASFx3DDPartNoRemoteAread-onlycurrentf2000EAS Series card fiber32 D/D information: Vendor part number
1.3.6.1.4.1.4756.20.731.20.1.208Columnf2000EASFx3DDFiberTypeRemoteAread-onlycurrentf2000EAS Series card fiber3 D/D information: Fiber Type
1.3.6.1.4.1.4756.20.731.20.1.209Columnf2000EASFx3DDWaveLenRemoteAread-onlycurrentf2000EAS Series card fiber3 D/D information: Wave length 1
1.3.6.1.4.1.4756.20.731.20.1.210Columnf2000EASFx3DDWaveLen2RemoteAread-onlycurrentf2000EAS Series card fiber3 D/D information: Wave length 2
1.3.6.1.4.1.4756.20.731.20.1.211Columnf2000EASFx3DDLinkLenRemoteAread-onlycurrentf2000EAS Series card fiber3 D/D information: Link length
1.3.6.1.4.1.4756.20.731.20.1.212Columnf2000EASFx3DDLenUnitRemoteAread-onlycurrentf2000EAS Series card fiber3 D/D information: Length Unit
1.3.6.1.4.1.4756.20.731.20.1.213Columnf2000EASFx3DDStatusRemoteAread-onlycurrentf2000EAS Series card fiber3 D/D information: Status Support
1.3.6.1.4.1.4756.20.731.20.1.214Columnf2000EASFx3DDRxSensRemoteAread-onlycurrentf2000EAS Series card fiber3 D/D information: Rx Sensitivity
1.3.6.1.4.1.4756.20.731.20.1.215Columnf2000EASFx3DDTxPWRRemoteAread-onlycurrentf2000EAS Series card fiber3 D/D information: Tx power
1.3.6.1.4.1.4756.20.731.20.1.216Columnf2000EASFx3DDRxPWRRemoteAread-onlycurrentf2000EAS Series card fiber3 D/D information: Rx power
1.3.6.1.4.1.4756.20.731.20.1.217Columnf2000EASFx3DDTempRemoteAread-onlycurrentf2000EAS Series card fiber3 D/D information: Temperature in degree C
1.3.6.1.4.1.4756.20.731.20.1.218Columnf2000EASFx3DDPWRMarginRemoteAread-onlycurrentf2000EAS Series card fiber3 D/D information: Power margin
1.3.6.1.4.1.4756.20.731.20.1.219Columnf2000EASFx3DDPWRLossRemoteAread-onlycurrentf2000EAS Series card fiber3 D/D information: Power loss
1.3.6.1.4.1.4756.20.731.20.1.220Columnf2000EASFx4DDRemoteAread-onlycurrentf2000EAS Series card fiber4 Digital Diagnostic function: 0:NO 1:Yes
1.3.6.1.4.1.4756.20.731.20.1.221Columnf2000EASFx4DDVendorRemoteAread-onlycurrentf2000EAS Series card fiber4 D/D information: Vendor name
1.3.6.1.4.1.4756.20.731.20.1.222Columnf2000EASFx4DDPartNoRemoteAread-onlycurrentf2000EAS Series card fiber4 D/D information: Vendor part number
1.3.6.1.4.1.4756.20.731.20.1.223Columnf2000EASFx4DDFiberTypeRemoteAread-onlycurrentf2000EAS Series card fiber4 D/D information: Fiber Type
1.3.6.1.4.1.4756.20.731.20.1.224Columnf2000EASFx4DDWaveLenRemoteAread-onlycurrentf2000EAS Series card fiber4 D/D information: Wave length 1
1.3.6.1.4.1.4756.20.731.20.1.225Columnf2000EASFx4DDWaveLen2RemoteAread-onlycurrentf2000EAS Series card fiber4 D/D information: Wave length 2
1.3.6.1.4.1.4756.20.731.20.1.226Columnf2000EASFx4DDLinkLenRemoteAread-onlycurrentf2000EAS Series card fiber4 D/D information: Link length
1.3.6.1.4.1.4756.20.731.20.1.227Columnf2000EASFx4DDLenUnitRemoteAread-onlycurrentf2000EAS Series card fiber4 D/D information: Length Unit
1.3.6.1.4.1.4756.20.731.20.1.228Columnf2000EASFx4DDStatusRemoteAread-onlycurrentf2000EAS Series card fiber4 D/D information: Status Support
1.3.6.1.4.1.4756.20.731.20.1.229Columnf2000EASFx4DDRxSensRemoteAread-onlycurrentf2000EAS Series card fiber4 D/D information: Rx Sensitivity
1.3.6.1.4.1.4756.20.731.20.1.230Columnf2000EASFx4DDTxPWRRemoteAread-onlycurrentf2000EAS Series card fiber4 D/D information: Tx power
1.3.6.1.4.1.4756.20.731.20.1.231Columnf2000EASFx4DDRxPWRRemoteAread-onlycurrentf2000EAS Series card fiber4 D/D information: Rx power
1.3.6.1.4.1.4756.20.731.20.1.232Columnf2000EASFx4DDTempRemoteAread-onlycurrentf2000EAS Series card fiber4 D/D information: Temperature in degree C
1.3.6.1.4.1.4756.20.731.20.1.233Columnf2000EASFx4DDPWRMarginRemoteAread-onlycurrentf2000EAS Series card fiber4 D/D information: Power margin
1.3.6.1.4.1.4756.20.731.20.1.234Columnf2000EASFx4DDPWRLossRemoteAread-onlycurrentf2000EAS Series card fiber4 D/D information: Power loss
1.3.6.1.4.1.4756.20.731.20.1.235Columnf2000EASTestRemoteAread-onlycurrentf2000EAS Series card test led sts: 0: Off 1: On
1.3.6.1.4.1.4756.20.731.20.1.236Columnf2000EASClearPortCounterRemoteAread-writecurrentf2000EAS Series card clear port counter: 0: Off 1: Action
1.3.6.1.4.1.4756.20.731.20.1.237Columnf2000EASAggrSourceMACAddrRemoteAread-writecurrentf2000EAS Series card Aggregation Mode Configuration: Source MAC Address 0: No 1: Yes
1.3.6.1.4.1.4756.20.731.20.1.238Columnf2000EASAggrDestinationMACAddrRemoteAread-writecurrentf2000EAS Series card Aggregation Mode Configuration: Destination MAC Address 0: No 1: Yes
1.3.6.1.4.1.4756.20.731.20.1.239Columnf2000EASAggrIPAddrRemoteAread-writecurrentf2000EAS Series card Aggregation Mode Configuration: IP Address 0: No 1: Yes
1.3.6.1.4.1.4756.20.731.20.1.240Columnf2000EASAggrTCPUDPPortNumRemoteAread-writecurrentf2000EAS Series card Aggregation Mode Configuration: TCP/UDP Port Number 0: No 1: Yes
1.3.6.1.4.1.4756.20.731.20.1.241Columnf2000EASAggrGroupPort1ConfRemoteAread-writecurrentf2000EAS Series card Aggregation Group Port1 Configuration: 0: Normal 1: ID1 2: ID2
1.3.6.1.4.1.4756.20.731.20.1.242Columnf2000EASAggrGroupPort2ConfRemoteAread-writecurrentf2000EAS Series card Aggregation Group Port2 Configuration: 0: Normal 1: ID1 2: ID2
1.3.6.1.4.1.4756.20.731.20.1.243Columnf2000EASAggrGroupPort3ConfRemoteAread-writecurrentf2000EAS Series card Aggregation Group Port3 Configuration: 0: Normal 1: ID1 2: ID2
1.3.6.1.4.1.4756.20.731.20.1.244Columnf2000EASAggrGroupPort4ConfRemoteAread-writecurrentf2000EAS Series card Aggregation Group Port4 Configuration: 0: Normal 1: ID1 2: ID2
1.3.6.1.4.1.4756.20.731.20.1.245Columnf2000EASPort1LACPEnabledRemoteAread-writecurrentf2000EAS Series card Port1 LACP Enabled: 0: No 1: Yes
1.3.6.1.4.1.4756.20.731.20.1.246Columnf2000EASPort1LACPKEYRemoteAread-writecurrentf2000EAS Series card Port1 LACP Key value: The Key value incurred by the port, range 0-65535.The value of 0 means auto.
1.3.6.1.4.1.4756.20.731.20.1.247Columnf2000EASPort1LACPRoleRemoteAread-writecurrentf2000EAS Series card Port1 LACP Role: 0: Passive 1: Active
1.3.6.1.4.1.4756.20.731.20.1.248Columnf2000EASPort1LACPTimeOutRemoteAread-writecurrentf2000EAS Series card Port1 LACP Time out: 0: Slow 1: Fast
1.3.6.1.4.1.4756.20.731.20.1.249Columnf2000EASPort1LACPPrioRemoteAread-writecurrentf2000EAS Series card Port1 LACP priority: The Key value incurred by the port, range 1-65535.
1.3.6.1.4.1.4756.20.731.20.1.250Columnf2000EASPort2LACPEnabledRemoteAread-writecurrentf2000EAS Series card Port2 LACP Enabled: 0: No 1: Yes
1.3.6.1.4.1.4756.20.731.20.1.251Columnf2000EASPort2LACPKEYRemoteAread-writecurrentf2000EAS Series card Port2 LACP Key value: The Key value incurred by the port, range 0-65535.The value of 0 means auto.
1.3.6.1.4.1.4756.20.731.20.1.252Columnf2000EASPort2LACPRoleRemoteAread-writecurrentf2000EAS Series card Port2 LACP Role: 0: Passive 1: Active
1.3.6.1.4.1.4756.20.731.20.1.253Columnf2000EASPort2LACPTimeOutRemoteAread-writecurrentf2000EAS Series card Port2 LACP Time out: 0: Slow 1: Fast
1.3.6.1.4.1.4756.20.731.20.1.254Columnf2000EASPort2LACPPrioRemoteAread-writecurrentf2000EAS Series card Port2 LACP priority: The Key value incurred by the port, range 1-65535.
1.3.6.1.4.1.4756.20.731.20.1.255Columnf2000EASPort3LACPEnabledRemoteAread-writecurrentf2000EAS Series card Port3 LACP Enabled: 0: No 1: Yes
1.3.6.1.4.1.4756.20.731.20.1.256Columnf2000EASPort3LACPKEYRemoteAread-writecurrentf2000EAS Series card Port3 LACP Key value: The Key value incurred by the port, range 0-65535.The value of 0 means auto.
1.3.6.1.4.1.4756.20.731.20.1.257Columnf2000EASPort3LACPRoleRemoteAread-writecurrentf2000EAS Series card Port3 LACP Role: 0: Passive 1: Active
1.3.6.1.4.1.4756.20.731.20.1.258Columnf2000EASPort3LACPTimeOutRemoteAread-writecurrentf2000EAS Series card Port3 LACP Time out: 0: Slow 1: Fast
1.3.6.1.4.1.4756.20.731.20.1.259Columnf2000EASPort3LACPPrioRemoteAread-writecurrentf2000EAS Series card Port3 LACP priority: The Key value incurred by the port, range 1-65535.
1.3.6.1.4.1.4756.20.731.20.1.260Columnf2000EASPort4LACPEnabledRemoteAread-writecurrentf2000EAS Series card Port4 LACP Enabled: 0: No 1: Yes
1.3.6.1.4.1.4756.20.731.20.1.261Columnf2000EASPort4LACPKEYRemoteAread-writecurrentf2000EAS Series card Port4 LACP Key value: The Key value incurred by the port, range 0-65535.The value of 0 means auto.
1.3.6.1.4.1.4756.20.731.20.1.262Columnf2000EASPort4LACPRoleRemoteAread-writecurrentf2000EAS Series card Port4 LACP Role: 0: Passive 1: Active
1.3.6.1.4.1.4756.20.731.20.1.263Columnf2000EASPort4LACPTimeOutRemoteAread-writecurrentf2000EAS Series card Port4 LACP Time out: 0: Slow 1: Fast
1.3.6.1.4.1.4756.20.731.20.1.264Columnf2000EASPort4LACPPrioRemoteAread-writecurrentf2000EAS Series card Port4 LACP priority: The Key value incurred by the port, range 1-65535.
1.3.6.1.4.1.4756.20.731.20.1.265Columnf2000EASPort1LACPstsRemoteAread-onlycurrentf2000EAS Series card Port1 LACP status: 0: No 1: Yes 2: Standby
1.3.6.1.4.1.4756.20.731.20.1.266Columnf2000EASPort1LACPKEYstsRemoteAread-onlycurrentf2000EAS Series card Port1 LACP status: Key
1.3.6.1.4.1.4756.20.731.20.1.267Columnf2000EASPort1LACPAggrIDstsRemoteAread-onlycurrentf2000EAS Series card Port1 LACP status: Aggr ID
1.3.6.1.4.1.4756.20.731.20.1.268Columnf2000EASPort1LACPParnterSysIDstsRemoteAread-onlycurrentf2000EAS Series card Port1 LACP status: Parnter System ID
1.3.6.1.4.1.4756.20.731.20.1.269Columnf2000EASPort1LACPParnterPortstsRemoteAread-onlycurrentf2000EAS Series card Port1 LACP status: Parnter Port Status
1.3.6.1.4.1.4756.20.731.20.1.270Columnf2000EASPort1LACPParnterProistsRemoteAread-onlycurrentf2000EAS Series card Port1 LACP status: Parnter Priority
1.3.6.1.4.1.4756.20.731.20.1.271Columnf2000EASPort2LACPstsRemoteAread-onlycurrentf2000EAS Series card Port2 LACP status: 0: No 1: Yes 2: Standby
1.3.6.1.4.1.4756.20.731.20.1.272Columnf2000EASPort2LACPKEYstsRemoteAread-onlycurrentf2000EAS Series card Port2 LACP status: Key
1.3.6.1.4.1.4756.20.731.20.1.273Columnf2000EASPort2LACPAggrIDstsRemoteAread-onlycurrentf2000EAS Series card Port2 LACP status: Aggr ID
1.3.6.1.4.1.4756.20.731.20.1.274Columnf2000EASPort2LACPParnterSysIDstsRemoteAread-onlycurrentf2000EAS Series card Port2 LACP status: Parnter System ID
1.3.6.1.4.1.4756.20.731.20.1.275Columnf2000EASPort2LACPParnterPortstsRemoteAread-onlycurrentf2000EAS Series card Port2 LACP status: Parnter Port Status
1.3.6.1.4.1.4756.20.731.20.1.276Columnf2000EASPort2LACPParnterProistsRemoteAread-onlycurrentf2000EAS Series card Port2 LACP status: Parnter Priority
1.3.6.1.4.1.4756.20.731.20.1.277Columnf2000EASPort3LACPstsRemoteAread-onlycurrentf2000EAS Series card Port3 LACP status: 0: No 1: Yes 2: Standby
1.3.6.1.4.1.4756.20.731.20.1.278Columnf2000EASPort3LACPKEYstsRemoteAread-onlycurrentf2000EAS Series card Port3 LACP status: Key
1.3.6.1.4.1.4756.20.731.20.1.279Columnf2000EASPort3LACPAggrIDstsRemoteAread-onlycurrentf2000EAS Series card Port3 LACP status: Aggr ID
1.3.6.1.4.1.4756.20.731.20.1.280Columnf2000EASPort3LACPParnterSysIDstsRemoteAread-onlycurrentf2000EAS Series card Port3 LACP status: Parnter System ID
1.3.6.1.4.1.4756.20.731.20.1.281Columnf2000EASPort3LACPParnterPortstsRemoteAread-onlycurrentf2000EAS Series card Port3 LACP status: Parnter Port Status
1.3.6.1.4.1.4756.20.731.20.1.282Columnf2000EASPort3LACPParnterProistsRemoteAread-onlycurrentf2000EAS Series card Port3 LACP status: Parnter Priority
1.3.6.1.4.1.4756.20.731.20.1.283Columnf2000EASPort4LACPstsRemoteAread-onlycurrentf2000EAS Series card Port4 LACP status: 0: No 1: Yes 2: Standby
1.3.6.1.4.1.4756.20.731.20.1.284Columnf2000EASPort4LACPKEYstsRemoteAread-onlycurrentf2000EAS Series card Port4 LACP status: Key
1.3.6.1.4.1.4756.20.731.20.1.285Columnf2000EASPort4LACPAggrIDstsRemoteAread-onlycurrentf2000EAS Series card Port4 LACP status: Aggr ID
1.3.6.1.4.1.4756.20.731.20.1.286Columnf2000EASPort4LACPParnterSysIDstsRemoteAread-onlycurrentf2000EAS Series card Port4 LACP status: Parnter System ID
1.3.6.1.4.1.4756.20.731.20.1.287Columnf2000EASPort4LACPParnterPortstsRemoteAread-onlycurrentf2000EAS Series card Port4 LACP status: Parnter Port Status
1.3.6.1.4.1.4756.20.731.20.1.288Columnf2000EASPort4LACPParnterProistsRemoteAread-onlycurrentf2000EAS Series card Port4 LACP status: Parnter Priority
1.3.6.1.4.1.4756.20.731.20.1.289Columnf2000EASOAMPort1EnableRemoteAread-onlycurrentf2000EAS Series card Port1 OAM: 0: Off 1: On
1.3.6.1.4.1.4756.20.731.20.1.290Columnf2000EASOAMPort1ModeRemoteAread-writecurrentf2000EAS Series card Port1 OAM: 0: Passive 1: Active
1.3.6.1.4.1.4756.20.731.20.1.291Columnf2000EASOAMPort1LoopBackRemoteAread-writecurrentf2000EAS Series card Port1 OAM LoopBack: 0: Off 1: On
1.3.6.1.4.1.4756.20.731.20.1.292Columnf2000EASOAMPort1LinkMonitorRemoteAread-writecurrentf2000EAS Series card Port1 OAM Link Monitor: 0: Off 1: On
1.3.6.1.4.1.4756.20.731.20.1.293Columnf2000EASOAMPort1MIBRetrievalRemoteAread-writecurrentf2000EAS Series card Port1 OAM MIB Retrieval: 0: Off 1: On
1.3.6.1.4.1.4756.20.731.20.1.294Columnf2000EASOAMPort1LoopBackOPRemoteAread-onlycurrentf2000EAS Series card Port1 OAM LoopBack operation: 0: Off 1: On
1.3.6.1.4.1.4756.20.731.20.1.295Columnf2000EASOAMPort2EnableRemoteAread-onlycurrentf2000EAS Series card Port2 OAM: 0: Off 1: On
1.3.6.1.4.1.4756.20.731.20.1.296Columnf2000EASOAMPort2ModeRemoteAread-writecurrentf2000EAS Series card Port2 OAM: 0: Passive 1: Active
1.3.6.1.4.1.4756.20.731.20.1.297Columnf2000EASOAMPort2LoopBackRemoteAread-writecurrentf2000EAS Series card Port2 OAM LoopBack: 0: Off 1: On
1.3.6.1.4.1.4756.20.731.20.1.298Columnf2000EASOAMPort2LinkMonitorRemoteAread-writecurrentf2000EAS Series card Port2 OAM Link Monitor: 0: Off 1: On
1.3.6.1.4.1.4756.20.731.20.1.299Columnf2000EASOAMPort2MIBRetrievalRemoteAread-writecurrentf2000EAS Series card Port2 OAM MIB Retrieval: 0: Off 1: On
1.3.6.1.4.1.4756.20.731.20.1.300Columnf2000EASOAMPort2LoopBackOPRemoteAread-onlycurrentf2000EAS Series card Port2 OAM LoopBack operation: 0: Off 1: On
1.3.6.1.4.1.4756.20.731.20.1.301Columnf2000EASOAMPort3EnableRemoteAread-onlycurrentf2000EAS Series card Port3 OAM: 0: Off 1: On
1.3.6.1.4.1.4756.20.731.20.1.302Columnf2000EASOAMPort3ModeRemoteAread-writecurrentf2000EAS Series card Port3 OAM: 0: Passive 1: Active
1.3.6.1.4.1.4756.20.731.20.1.303Columnf2000EASOAMPort3LoopBackRemoteAread-writecurrentf2000EAS Series card Port3 OAM: 0: Off 1: On
1.3.6.1.4.1.4756.20.731.20.1.304Columnf2000EASOAMPort3LinkMonitorRemoteAread-writecurrentf2000EAS Series card Port3 OAM Link Monitor: 0: Off 1: On
1.3.6.1.4.1.4756.20.731.20.1.305Columnf2000EASOAMPort3MIBRetrievalRemoteAread-writecurrentf2000EAS Series card Port3 OAM MIB Retrieval: 0: Off 1: On
1.3.6.1.4.1.4756.20.731.20.1.306Columnf2000EASOAMPort3LoopBackOPRemoteAread-onlycurrentf2000EAS Series card Port3 OAM LoopBack operation: 0: Disable 1: Enable
1.3.6.1.4.1.4756.20.731.20.1.307Columnf2000EASOAMPort4EnableRemoteAread-onlycurrentf2000EAS Series card Port4 OAM: 0: Off 1: On
1.3.6.1.4.1.4756.20.731.20.1.308Columnf2000EASOAMPort4ModeRemoteAread-writecurrentf2000EAS Series card Port4 OAM: 0: Passive 1: Active
1.3.6.1.4.1.4756.20.731.20.1.309Columnf2000EASOAMPort4LoopBackRemoteAread-writecurrentf2000EAS Series card Port4 OAM: 0: Off 1: On
1.3.6.1.4.1.4756.20.731.20.1.310Columnf2000EASOAMPort4LinkMonitorRemoteAread-writecurrentf2000EAS Series card Port4 OAM Link Monitor: 0: Off 1: On
1.3.6.1.4.1.4756.20.731.20.1.311Columnf2000EASOAMPort4MIBRetrievalRemoteAread-writecurrentf2000EAS Series card Port4 OAM MIB Retrieval: 0: Off 1: On
1.3.6.1.4.1.4756.20.731.20.1.312Columnf2000EASOAMPort4LoopBackOPRemoteAread-onlycurrentf2000EAS Series card Port4 OAM LoopBack operation: 0: On 1: Off
1.3.6.1.4.1.4756.20.731.20.1.313Columnf2000EASPort1EFEErrorWindowRemoteAread-writecurrentf2000EAS Series card Port1 Link Event Configuration: Error Frame Event - Error Window
1.3.6.1.4.1.4756.20.731.20.1.314Columnf2000EASPort1EFEErrorThresholdRemoteAread-writecurrentf2000EAS Series card Port1 Link Event Configuration: Error Frame Event - Error Threshold
1.3.6.1.4.1.4756.20.731.20.1.315Columnf2000EASPort1SPEEErrorWindowRemoteAread-writecurrentf2000EAS Series card Port1 Link Event Configuration: Symbol Period Error Event - Error Window
1.3.6.1.4.1.4756.20.731.20.1.316Columnf2000EASPort1SPEEErrorThresholdRemoteAread-writecurrentf2000EAS Series card Port1 Link Event Configuration: Symbol Period Error Event - Error Threshold
1.3.6.1.4.1.4756.20.731.20.1.317Columnf2000EASPort1SSEErrorWindowRemoteAread-writecurrentf2000EAS Series card Port1 Link Event Configuration: Seconds Summary Event - Error Window
1.3.6.1.4.1.4756.20.731.20.1.318Columnf2000EASPort1SSEErrorThresholdRemoteAread-writecurrentf2000EAS Series card Port1 Link Event Configuration: Seconds Summary Event - Error Threshold
1.3.6.1.4.1.4756.20.731.20.1.319Columnf2000EASPort2EFEErrorWindowRemoteAread-writecurrentf2000EAS Series card Port2 Link Event Configuration: Error Frame Event - Error Window
1.3.6.1.4.1.4756.20.731.20.1.320Columnf2000EASPort2EFEErrorThresholdRemoteAread-writecurrentf2000EAS Series card Port2 Link Event Configuration: Error Frame Event - Error Threshold
1.3.6.1.4.1.4756.20.731.20.1.321Columnf2000EASPort2SPEEErrorWindowRemoteAread-writecurrentf2000EAS Series card Port2 Link Event Configuration: Symbol Period Error Event - Error Window
1.3.6.1.4.1.4756.20.731.20.1.322Columnf2000EASPort2SPEEErrorThresholdRemoteAread-writecurrentf2000EAS Series card Port2 Link Event Configuration: Symbol Period Error Event - Error Threshold
1.3.6.1.4.1.4756.20.731.20.1.323Columnf2000EASPort2SSEErrorWindowRemoteAread-writecurrentf2000EAS Series card Port2 Link Event Configuration: Seconds Summary Event - Error Window
1.3.6.1.4.1.4756.20.731.20.1.324Columnf2000EASPort2SSEErrorThresholdRemoteAread-writecurrentf2000EAS Series card Port2 Link Event Configuration: Seconds Summary Event - Error Threshold
1.3.6.1.4.1.4756.20.731.20.1.325Columnf2000EASPort3EFEErrorWindowRemoteAread-writecurrentf2000EAS Series card Port3 Link Event Configuration: Error Frame Event - Error Window
1.3.6.1.4.1.4756.20.731.20.1.326Columnf2000EASPort3EFEErrorThresholdRemoteAread-writecurrentf2000EAS Series card Port3 Link Event Configuration: Error Frame Event - Error Threshold
1.3.6.1.4.1.4756.20.731.20.1.327Columnf2000EASPort3SPEEErrorWindowRemoteAread-writecurrentf2000EAS Series card Port3 Link Event Configuration: Symbol Period Error Event - Error Window
1.3.6.1.4.1.4756.20.731.20.1.328Columnf2000EASPort3SPEEErrorThresholdRemoteAread-writecurrentf2000EAS Series card Port3 Link Event Configuration: Symbol Period Error Event - Error Threshold
1.3.6.1.4.1.4756.20.731.20.1.329Columnf2000EASPort3SSEErrorWindowRemoteAread-writecurrentf2000EAS Series card Port3 Link Event Configuration: Seconds Summary Event - Error Window
1.3.6.1.4.1.4756.20.731.20.1.330Columnf2000EASPort3SSEErrorThresholdRemoteAread-writecurrentf2000EAS Series card Port3 Link Event Configuration: Seconds Summary Event - Error Threshold
1.3.6.1.4.1.4756.20.731.20.1.331Columnf2000EASPort4EFEErrorWindowRemoteAread-writecurrentf2000EAS Series card Port4 Link Event Configuration: Error Frame Event - Error Window
1.3.6.1.4.1.4756.20.731.20.1.332Columnf2000EASPort4EFEErrorThresholdRemoteAread-writecurrentf2000EAS Series card Port4 Link Event Configuration: Error Frame Event - Error Threshold
1.3.6.1.4.1.4756.20.731.20.1.333Columnf2000EASPort4SPEEErrorWindowRemoteAread-writecurrentf2000EAS Series card Port4 Link Event Configuration: Symbol Period Error Event - Error Window
1.3.6.1.4.1.4756.20.731.20.1.334Columnf2000EASPort4SPEEErrorThresholdRemoteAread-writecurrentf2000EAS Series card Port4 Link Event Configuration: Symbol Period Error Event - Error Threshold
1.3.6.1.4.1.4756.20.731.20.1.335Columnf2000EASPort4SSEErrorWindowRemoteAread-writecurrentf2000EAS Series card Port4 Link Event Configuration: Seconds Summary Event - Error Window
1.3.6.1.4.1.4756.20.731.20.1.336Columnf2000EASPort4SSEErrorThresholdRemoteAread-writecurrentf2000EAS Series card Port4 Link Event Configuration: Seconds Summary Event - Error Threshold
1.3.6.1.4.1.4756.20.731.20.1.337Columnf2000EASPort1RxOAMInfoPDURemoteAread-onlycurrentf2000EAS Series card Port1 Detailed Link OAM Statistics: Rx OAM Information PDU's
1.3.6.1.4.1.4756.20.731.20.1.338Columnf2000EASPort1RxUniqueErrorEventRemoteAread-onlycurrentf2000EAS Series card Port1 Detailed Link OAM Statistics: Rx Unique Error Event Notificatio
1.3.6.1.4.1.4756.20.731.20.1.339Columnf2000EASPort1RxDuplicateErrorEventRemoteAread-onlycurrentf2000EAS Series card Port1 Detailed Link OAM Statistics: Rx Duplicate Error Event Notification
1.3.6.1.4.1.4756.20.731.20.1.340Columnf2000EASPort1RxLoopBackControlRemoteAread-onlycurrentf2000EAS Series card Port1 Detailed Link OAM Statistics: Rx Loopback Control
1.3.6.1.4.1.4756.20.731.20.1.341Columnf2000EASPort1RxVariableRequestRemoteAread-onlycurrentf2000EAS Series card Port1 Detailed Link OAM Statistics: Rx Variable Request
1.3.6.1.4.1.4756.20.731.20.1.342Columnf2000EASPort1RxVariableResponseRemoteAread-onlycurrentf2000EAS Series card Port1 Detailed Link OAM Statistics: Rx Variable Response
1.3.6.1.4.1.4756.20.731.20.1.343Columnf2000EASPort1RxOrgSpecificPDURemoteAread-onlycurrentf2000EAS Series card Port1 Detailed Link OAM Statistics: Rx Org Specific PDU's
1.3.6.1.4.1.4756.20.731.20.1.344Columnf2000EASPort1RxUnsupportedCodesRemoteAread-onlycurrentf2000EAS Series card Port1 Detailed Link OAM Statistics: Rx Unsupported Codes
1.3.6.1.4.1.4756.20.731.20.1.345Columnf2000EASPort1RxLinkFaultPDURemoteAread-onlycurrentf2000EAS Series card Port1 Detailed Link OAM Statistics: Rx Link Fault PDU's
1.3.6.1.4.1.4756.20.731.20.1.346Columnf2000EASPort1RxDyingGaspRemoteAread-onlycurrentf2000EAS Series card Port1 Detailed Link OAM Statistics: Rx Dying Gasp
1.3.6.1.4.1.4756.20.731.20.1.347Columnf2000EASPort1RxCriticalEventPDURemoteAread-onlycurrentf2000EAS Series card Port1 Detailed Link OAM Statistics: Rx Dying Gasp
1.3.6.1.4.1.4756.20.731.20.1.348Columnf2000EASPort1TxOAMInfoPDURemoteAread-onlycurrentf2000EAS Series card Port1 Detailed Link OAM Statistics: Tx OAM Information PDU's
1.3.6.1.4.1.4756.20.731.20.1.349Columnf2000EASPort1TxUniqueErrorEventRemoteAread-onlycurrentf2000EAS Series card Port1 Detailed Link OAM Statistics: Tx Unique Error Event Notificatio
1.3.6.1.4.1.4756.20.731.20.1.350Columnf2000EASPort1TxDuplicateErrorEventRemoteAread-onlycurrentf2000EAS Series card Port1 Detailed Link OAM Statistics: Tx Duplicate Error Event Notification
1.3.6.1.4.1.4756.20.731.20.1.351Columnf2000EASPort1TxLoopBackControlRemoteAread-onlycurrentf2000EAS Series card Port1 Detailed Link OAM Statistics: Tx Loopback Control
1.3.6.1.4.1.4756.20.731.20.1.352Columnf2000EASPort1TxVariableRequestRemoteAread-onlycurrentf2000EAS Series card Port1 Detailed Link OAM Statistics: Tx Variable Request
1.3.6.1.4.1.4756.20.731.20.1.353Columnf2000EASPort1TxVariableResponseRemoteAread-onlycurrentf2000EAS Series card Port1 Detailed Link OAM Statistics: Tx Variable Response
1.3.6.1.4.1.4756.20.731.20.1.354Columnf2000EASPort1TxOrgSpecificPDURemoteAread-onlycurrentf2000EAS Series card Port1 Detailed Link OAM Statistics: Tx Org Specific PDU's
1.3.6.1.4.1.4756.20.731.20.1.355Columnf2000EASPort1TxUnsupportedCodesRemoteAread-onlycurrentf2000EAS Series card Port1 Detailed Link OAM Statistics: Tx Unsupported Codes
1.3.6.1.4.1.4756.20.731.20.1.356Columnf2000EASPort1TxLinkFaultPDURemoteAread-onlycurrentf2000EAS Series card Port1 Detailed Link OAM Statistics: Tx Link Fault PDU's
1.3.6.1.4.1.4756.20.731.20.1.357Columnf2000EASPort1TxDyingGaspRemoteAread-onlycurrentf2000EAS Series card Port1 Detailed Link OAM Statistics: Tx Dying Gasp
1.3.6.1.4.1.4756.20.731.20.1.358Columnf2000EASPort1TxCriticalEventPDURemoteAread-onlycurrentf2000EAS Series card Port1 Detailed Link OAM Statistics: Tx Dying Gasp
1.3.6.1.4.1.4756.20.731.20.1.359Columnf2000EASPort2RxOAMInfoPDURemoteAread-onlycurrentf2000EAS Series card Port2 Detailed Link OAM Statistics: Rx OAM Information PDU's
1.3.6.1.4.1.4756.20.731.20.1.360Columnf2000EASPort2RxUniqueErrorEventRemoteAread-onlycurrentf2000EAS Series card Port2 Detailed Link OAM Statistics: Rx Unique Error Event Notificatio
1.3.6.1.4.1.4756.20.731.20.1.361Columnf2000EASPort2RxDuplicateErrorEventRemoteAread-onlycurrentf2000EAS Series card Port2 Detailed Link OAM Statistics: Rx Duplicate Error Event Notification
1.3.6.1.4.1.4756.20.731.20.1.362Columnf2000EASPort2RxLoopBackControlRemoteAread-onlycurrentf2000EAS Series card Port2 Detailed Link OAM Statistics: Rx Loopback Control
1.3.6.1.4.1.4756.20.731.20.1.363Columnf2000EASPort2RxVariableRequestRemoteAread-onlycurrentf2000EAS Series card Port2 Detailed Link OAM Statistics: Rx Variable Request
1.3.6.1.4.1.4756.20.731.20.1.364Columnf2000EASPort2RxVariableResponseRemoteAread-onlycurrentf2000EAS Series card Port2 Detailed Link OAM Statistics: Rx Variable Response
1.3.6.1.4.1.4756.20.731.20.1.365Columnf2000EASPort2RxOrgSpecificPDURemoteAread-onlycurrentf2000EAS Series card Port2 Detailed Link OAM Statistics: Rx Org Specific PDU's
1.3.6.1.4.1.4756.20.731.20.1.366Columnf2000EASPort2RxUnsupportedCodesRemoteAread-onlycurrentf2000EAS Series card Port2 Detailed Link OAM Statistics: Rx Unsupported Codes
1.3.6.1.4.1.4756.20.731.20.1.367Columnf2000EASPort2RxLinkFaultPDURemoteAread-onlycurrentf2000EAS Series card Port2 Detailed Link OAM Statistics: Rx Link Fault PDU's
1.3.6.1.4.1.4756.20.731.20.1.368Columnf2000EASPort2RxDyingGaspRemoteAread-onlycurrentf2000EAS Series card Port2 Detailed Link OAM Statistics: Rx Dying Gasp
1.3.6.1.4.1.4756.20.731.20.1.369Columnf2000EASPort2RxCriticalEventPDURemoteAread-onlycurrentf2000EAS Series card Port2 Detailed Link OAM Statistics: Rx Dying Gasp
1.3.6.1.4.1.4756.20.731.20.1.370Columnf2000EASPort2TxOAMInfoPDURemoteAread-onlycurrentf2000EAS Series card Port2 Detailed Link OAM Statistics: Tx OAM Information PDU's
1.3.6.1.4.1.4756.20.731.20.1.371Columnf2000EASPort2TxUniqueErrorEventRemoteAread-onlycurrentf2000EAS Series card Port2 Detailed Link OAM Statistics: Tx Unique Error Event Notificatio
1.3.6.1.4.1.4756.20.731.20.1.372Columnf2000EASPort2TxDuplicateErrorEventRemoteAread-onlycurrentf2000EAS Series card Port2 Detailed Link OAM Statistics: Tx Duplicate Error Event Notification
1.3.6.1.4.1.4756.20.731.20.1.373Columnf2000EASPort2TxLoopBackControlRemoteAread-onlycurrentf2000EAS Series card Port2 Detailed Link OAM Statistics: Tx Loopback Control
1.3.6.1.4.1.4756.20.731.20.1.374Columnf2000EASPort2TxVariableRequestRemoteAread-onlycurrentf2000EAS Series card Port2 Detailed Link OAM Statistics: Tx Variable Request
1.3.6.1.4.1.4756.20.731.20.1.375Columnf2000EASPort2TxVariableResponseRemoteAread-onlycurrentf2000EAS Series card Port2 Detailed Link OAM Statistics: Tx Variable Response
1.3.6.1.4.1.4756.20.731.20.1.376Columnf2000EASPort2TxOrgSpecificPDURemoteAread-onlycurrentf2000EAS Series card Port2 Detailed Link OAM Statistics: Tx Org Specific PDU's
1.3.6.1.4.1.4756.20.731.20.1.377Columnf2000EASPort2TxUnsupportedCodesRemoteAread-onlycurrentf2000EAS Series card Port2 Detailed Link OAM Statistics: Tx Unsupported Codes
1.3.6.1.4.1.4756.20.731.20.1.378Columnf2000EASPort2TxLinkFaultPDURemoteAread-onlycurrentf2000EAS Series card Port2 Detailed Link OAM Statistics: Tx Link Fault PDU's
1.3.6.1.4.1.4756.20.731.20.1.379Columnf2000EASPort2TxDyingGaspRemoteAread-onlycurrentf2000EAS Series card Port2 Detailed Link OAM Statistics: Tx Dying Gasp
1.3.6.1.4.1.4756.20.731.20.1.380Columnf2000EASPort2TxCriticalEventPDURemoteAread-onlycurrentf2000EAS Series card Port2 Detailed Link OAM Statistics: Tx Dying Gasp
1.3.6.1.4.1.4756.20.731.20.1.381Columnf2000EASPort3RxOAMInfoPDURemoteAread-onlycurrentf2000EAS Series card Port3 Detailed Link OAM Statistics: Rx OAM Information PDU's
1.3.6.1.4.1.4756.20.731.20.1.382Columnf2000EASPort3RxUniqueErrorEventRemoteAread-onlycurrentf2000EAS Series card Port3 Detailed Link OAM Statistics: Rx Unique Error Event Notificatio
1.3.6.1.4.1.4756.20.731.20.1.383Columnf2000EASPort3RxDuplicateErrorEventRemoteAread-onlycurrentf2000EAS Series card Port3 Detailed Link OAM Statistics: Rx Duplicate Error Event Notification
1.3.6.1.4.1.4756.20.731.20.1.384Columnf2000EASPort3RxLoopBackControlRemoteAread-onlycurrentf2000EAS Series card Port3 Detailed Link OAM Statistics: Rx Loopback Control
1.3.6.1.4.1.4756.20.731.20.1.385Columnf2000EASPort3RxVariableRequestRemoteAread-onlycurrentf2000EAS Series card Port3 Detailed Link OAM Statistics: Rx Variable Request
1.3.6.1.4.1.4756.20.731.20.1.386Columnf2000EASPort3RxVariableResponseRemoteAread-onlycurrentf2000EAS Series card Port3 Detailed Link OAM Statistics: Rx Variable Response
1.3.6.1.4.1.4756.20.731.20.1.387Columnf2000EASPort3RxOrgSpecificPDURemoteAread-onlycurrentf2000EAS Series card Port3 Detailed Link OAM Statistics: Rx Org Specific PDU's
1.3.6.1.4.1.4756.20.731.20.1.388Columnf2000EASPort3RxUnsupportedCodesRemoteAread-onlycurrentf2000EAS Series card Port3 Detailed Link OAM Statistics: Rx Unsupported Codes
1.3.6.1.4.1.4756.20.731.20.1.389Columnf2000EASPort3RxLinkFaultPDURemoteAread-onlycurrentf2000EAS Series card Port3 Detailed Link OAM Statistics: Rx Link Fault PDU's
1.3.6.1.4.1.4756.20.731.20.1.390Columnf2000EASPort3RxDyingGaspRemoteAread-onlycurrentf2000EAS Series card Port3 Detailed Link OAM Statistics: Rx Dying Gasp
1.3.6.1.4.1.4756.20.731.20.1.391Columnf2000EASPort3RxCriticalEventPDURemoteAread-onlycurrentf2000EAS Series card Port3 Detailed Link OAM Statistics: Rx Dying Gasp
1.3.6.1.4.1.4756.20.731.20.1.392Columnf2000EASPort3TxOAMInfoPDURemoteAread-onlycurrentf2000EAS Series card Port3 Detailed Link OAM Statistics: Tx OAM Information PDU's
1.3.6.1.4.1.4756.20.731.20.1.393Columnf2000EASPort3TxUniqueErrorEventRemoteAread-onlycurrentf2000EAS Series card Port3 Detailed Link OAM Statistics: Tx Unique Error Event Notificatio
1.3.6.1.4.1.4756.20.731.20.1.394Columnf2000EASPort3TxDuplicateErrorEventRemoteAread-onlycurrentf2000EAS Series card Port3 Detailed Link OAM Statistics: Tx Duplicate Error Event Notification
1.3.6.1.4.1.4756.20.731.20.1.395Columnf2000EASPort3TxLoopBackControlRemoteAread-onlycurrentf2000EAS Series card Port3 Detailed Link OAM Statistics: Tx Loopback Control
1.3.6.1.4.1.4756.20.731.20.1.396Columnf2000EASPort3TxVariableRequestRemoteAread-onlycurrentf2000EAS Series card Port3 Detailed Link OAM Statistics: Tx Variable Request
1.3.6.1.4.1.4756.20.731.20.1.397Columnf2000EASPort3TxVariableResponseRemoteAread-onlycurrentf2000EAS Series card Port3 Detailed Link OAM Statistics: Tx Variable Response
1.3.6.1.4.1.4756.20.731.20.1.398Columnf2000EASPort3TxOrgSpecificPDURemoteAread-onlycurrentf2000EAS Series card Port3 Detailed Link OAM Statistics: Tx Org Specific PDU's
1.3.6.1.4.1.4756.20.731.20.1.399Columnf2000EASPort3TxUnsupportedCodesRemoteAread-onlycurrentf2000EAS Series card Port3 Detailed Link OAM Statistics: Tx Unsupported Codes
1.3.6.1.4.1.4756.20.731.20.1.400Columnf2000EASPort3TxLinkFaultPDURemoteAread-onlycurrentf2000EAS Series card Port3 Detailed Link OAM Statistics: Tx Link Fault PDU's
1.3.6.1.4.1.4756.20.731.20.1.401Columnf2000EASPort3TxDyingGaspRemoteAread-onlycurrentf2000EAS Series card Port3 Detailed Link OAM Statistics: Tx Dying Gasp
1.3.6.1.4.1.4756.20.731.20.1.402Columnf2000EASPort3TxCriticalEventPDURemoteAread-onlycurrentf2000EAS Series card Port3 Detailed Link OAM Statistics: Tx Dying Gasp
1.3.6.1.4.1.4756.20.731.20.1.403Columnf2000EASPort4RxOAMInfoPDURemoteAread-onlycurrentf2000EAS Series card Port4 Detailed Link OAM Statistics: Rx OAM Information PDU's
1.3.6.1.4.1.4756.20.731.20.1.404Columnf2000EASPort4RxUniqueErrorEventRemoteAread-onlycurrentf2000EAS Series card Port4 Detailed Link OAM Statistics: Rx Unique Error Event Notificatio
1.3.6.1.4.1.4756.20.731.20.1.405Columnf2000EASPort4RxDuplicateErrorEventRemoteAread-onlycurrentf2000EAS Series card Port4 Detailed Link OAM Statistics: Rx Duplicate Error Event Notification
1.3.6.1.4.1.4756.20.731.20.1.406Columnf2000EASPort4RxLoopBackControlRemoteAread-onlycurrentf2000EAS Series card Port4 Detailed Link OAM Statistics: Rx Loopback Control
1.3.6.1.4.1.4756.20.731.20.1.407Columnf2000EASPort4RxVariableRequestRemoteAread-onlycurrentf2000EAS Series card Port4 Detailed Link OAM Statistics: Rx Variable Request
1.3.6.1.4.1.4756.20.731.20.1.408Columnf2000EASPort4RxVariableResponseRemoteAread-onlycurrentf2000EAS Series card Port4 Detailed Link OAM Statistics: Rx Variable Response
1.3.6.1.4.1.4756.20.731.20.1.409Columnf2000EASPort4RxOrgSpecificPDURemoteAread-onlycurrentf2000EAS Series card Port4 Detailed Link OAM Statistics: Rx Org Specific PDU's
1.3.6.1.4.1.4756.20.731.20.1.410Columnf2000EASPort4RxUnsupportedCodesRemoteAread-onlycurrentf2000EAS Series card Port4 Detailed Link OAM Statistics: Rx Unsupported Codes
1.3.6.1.4.1.4756.20.731.20.1.411Columnf2000EASPort4RxLinkFaultPDURemoteAread-onlycurrentf2000EAS Series card Port4 Detailed Link OAM Statistics: Rx Link Fault PDU's
1.3.6.1.4.1.4756.20.731.20.1.412Columnf2000EASPort4RxDyingGaspRemoteAread-onlycurrentf2000EAS Series card Port4 Detailed Link OAM Statistics: Rx Dying Gasp
1.3.6.1.4.1.4756.20.731.20.1.413Columnf2000EASPort4RxCriticalEventPDURemoteAread-onlycurrentf2000EAS Series card Port4 Detailed Link OAM Statistics: Rx Dying Gasp
1.3.6.1.4.1.4756.20.731.20.1.414Columnf2000EASPort4TxOAMInfoPDURemoteAread-onlycurrentf2000EAS Series card Port4 Detailed Link OAM Statistics: Tx OAM Information PDU's
1.3.6.1.4.1.4756.20.731.20.1.415Columnf2000EASPort4TxUniqueErrorEventRemoteAread-onlycurrentf2000EAS Series card Port4 Detailed Link OAM Statistics: Tx Unique Error Event Notificatio
1.3.6.1.4.1.4756.20.731.20.1.416Columnf2000EASPort4TxDuplicateErrorEventRemoteAread-onlycurrentf2000EAS Series card Port4 Detailed Link OAM Statistics: Tx Duplicate Error Event Notification
1.3.6.1.4.1.4756.20.731.20.1.417Columnf2000EASPort4TxLoopBackControlRemoteAread-onlycurrentf2000EAS Series card Port4 Detailed Link OAM Statistics: Tx Loopback Control
1.3.6.1.4.1.4756.20.731.20.1.418Columnf2000EASPort4TxVariableRequestRemoteAread-onlycurrentf2000EAS Series card Port4 Detailed Link OAM Statistics: Tx Variable Request
1.3.6.1.4.1.4756.20.731.20.1.419Columnf2000EASPort4TxVariableResponseRemoteAread-onlycurrentf2000EAS Series card Port4 Detailed Link OAM Statistics: Tx Variable Response
1.3.6.1.4.1.4756.20.731.20.1.420Columnf2000EASPort4TxOrgSpecificPDURemoteAread-onlycurrentf2000EAS Series card Port4 Detailed Link OAM Statistics: Tx Org Specific PDU's
1.3.6.1.4.1.4756.20.731.20.1.421Columnf2000EASPort4TxUnsupportedCodesRemoteAread-onlycurrentf2000EAS Series card Port4 Detailed Link OAM Statistics: Tx Unsupported Codes
1.3.6.1.4.1.4756.20.731.20.1.422Columnf2000EASPort4TxLinkFaultPDURemoteAread-onlycurrentf2000EAS Series card Port4 Detailed Link OAM Statistics: Tx Link Fault PDU's
1.3.6.1.4.1.4756.20.731.20.1.423Columnf2000EASPort4TxDyingGaspRemoteAread-onlycurrentf2000EAS Series card Port4 Detailed Link OAM Statistics: Tx Dying Gasp
1.3.6.1.4.1.4756.20.731.20.1.424Columnf2000EASPort4TxCriticalEventPDURemoteAread-onlycurrentf2000EAS Series card Port4 Detailed Link OAM Statistics: Tx Dying Gasp
1.3.6.1.4.1.4756.20.731.20.1.425Columnf2000EASPort1PDUPermisionRemoteAread-onlycurrentf2000EAS Series card Detailed Link OAM Status for Port 1: PDU Permission
1.3.6.1.4.1.4756.20.731.20.1.426Columnf2000EASPort1DiscoveryStateRemoteAread-onlycurrentf2000EAS Series card Detailed Link OAM Status for Port 1: Discovery State
1.3.6.1.4.1.4756.20.731.20.1.427Columnf2000EASPort1PeerMACAddrRemoteAread-onlycurrentf2000EAS Series card Detailed Link OAM Status for Port 1: Discovery State
1.3.6.1.4.1.4756.20.731.20.1.428Columnf2000EASPort1LocalModeRemoteAread-onlycurrentf2000EAS Series card Detailed Link OAM Status for Port 1: RemoteA: Mode
1.3.6.1.4.1.4756.20.731.20.1.429Columnf2000EASPort1LocalUnOperationRemoteAread-onlycurrentf2000EAS Series card Detailed Link OAM Status for Port 1: RemoteA: Unidirectional Operation Support
1.3.6.1.4.1.4756.20.731.20.1.430Columnf2000EASPort1LocalRemoteLbRemoteAread-onlycurrentf2000EAS Series card Detailed Link OAM Status for Port 1: RemoteA: Remote Loopback Support
1.3.6.1.4.1.4756.20.731.20.1.431Columnf2000EASPort1LocalLMRemoteAread-onlycurrentf2000EAS Series card Detailed Link OAM Status for Port 1: RemoteA: Link Monitoring Support
1.3.6.1.4.1.4756.20.731.20.1.432Columnf2000EASPort1LocalMIBRetrievalRemoteAread-onlycurrentf2000EAS Series card Detailed Link OAM Status for Port 1: RemoteA: MIB Retrieval Support
1.3.6.1.4.1.4756.20.731.20.1.433Columnf2000EASPort1LocalMTUSizeRemoteAread-onlycurrentf2000EAS Series card Detailed Link OAM Status for Port 1: RemoteA: MTU Size
1.3.6.1.4.1.4756.20.731.20.1.434Columnf2000EASPort1LocalMultiStateRemoteAread-onlycurrentf2000EAS Series card Detailed Link OAM Status for Port 1: RemoteA: Multiplexer State
1.3.6.1.4.1.4756.20.731.20.1.435Columnf2000EASPort1LocalParserStateRemoteAread-onlycurrentf2000EAS Series card Detailed Link OAM Status for Port 1: RemoteA: Multiplexer State
1.3.6.1.4.1.4756.20.731.20.1.436Columnf2000EASPort1LocalOUIRemoteAread-onlycurrentf2000EAS Series card Detailed Link OAM Status for Port 1: RemoteA: Organizational Unique Identification
1.3.6.1.4.1.4756.20.731.20.1.437Columnf2000EASPort1LocalPDURevRemoteAread-onlycurrentf2000EAS Series card Detailed Link OAM Status for Port 1: RemoteA: PDU Revision
1.3.6.1.4.1.4756.20.731.20.1.438Columnf2000EASPort1PeerModeRemoteAread-onlycurrentf2000EAS Series card Detailed Link OAM Status for Port 1: Peer: Mode
1.3.6.1.4.1.4756.20.731.20.1.439Columnf2000EASPort1PeerUnOperationRemoteAread-onlycurrentf2000EAS Series card Detailed Link OAM Status for Port 1: Peer: Unidirectional Operation Support
1.3.6.1.4.1.4756.20.731.20.1.440Columnf2000EASPort1PeerRemoteLbRemoteAread-onlycurrentf2000EAS Series card Detailed Link OAM Status for Port 1: Peer: Remote Loopback Support
1.3.6.1.4.1.4756.20.731.20.1.441Columnf2000EASPort1PeerLMRemoteAread-onlycurrentf2000EAS Series card Detailed Link OAM Status for Port 1: Peer: Link Monitoring Support
1.3.6.1.4.1.4756.20.731.20.1.442Columnf2000EASPort1PeerMIBRetrievalRemoteAread-onlycurrentf2000EAS Series card Detailed Link OAM Status for Port 1: Peer: MIB Retrieval Support
1.3.6.1.4.1.4756.20.731.20.1.443Columnf2000EASPort1PeerMTUSizeRemoteAread-onlycurrentf2000EAS Series card Detailed Link OAM Status for Port 1: Peer: MTU Size
1.3.6.1.4.1.4756.20.731.20.1.444Columnf2000EASPort1PeerMultiStateRemoteAread-onlycurrentf2000EAS Series card Detailed Link OAM Status for Port 1: Peer: Multiplexer State
1.3.6.1.4.1.4756.20.731.20.1.445Columnf2000EASPort1PeerParserStateRemoteAread-onlycurrentf2000EAS Series card Detailed Link OAM Status for Port 1: Peer: Multiplexer State
1.3.6.1.4.1.4756.20.731.20.1.446Columnf2000EASPort1PeerOUIRemoteAread-onlycurrentf2000EAS Series card Detailed Link OAM Status for Port 1: Peer: Organizational Unique Identification
1.3.6.1.4.1.4756.20.731.20.1.447Columnf2000EASPort1PeerPDURevRemoteAread-onlycurrentf2000EAS Series card Detailed Link OAM Status for Port 1: Peer: PDU Revision
1.3.6.1.4.1.4756.20.731.20.1.448Columnf2000EASPort2PDUPermisionRemoteAread-onlycurrentf2000EAS Series card Detailed Link OAM Status for Port 2: PDU Permission
1.3.6.1.4.1.4756.20.731.20.1.449Columnf2000EASPort2DiscoveryStateRemoteAread-onlycurrentf2000EAS Series card Detailed Link OAM Status for Port 2: Discovery State
1.3.6.1.4.1.4756.20.731.20.1.450Columnf2000EASPort2PeerMACAddrRemoteAread-onlycurrentf2000EAS Series card Detailed Link OAM Status for Port 2: Discovery State
1.3.6.1.4.1.4756.20.731.20.1.451Columnf2000EASPort2LocalModeRemoteAread-onlycurrentf2000EAS Series card Detailed Link OAM Status for Port 2: RemoteA: Mode
1.3.6.1.4.1.4756.20.731.20.1.452Columnf2000EASPort2LocalUnOperationRemoteAread-onlycurrentf2000EAS Series card Detailed Link OAM Status for Port 2: RemoteA: Unidirectional Operation Support
1.3.6.1.4.1.4756.20.731.20.1.453Columnf2000EASPort2LocalRemoteLbRemoteAread-onlycurrentf2000EAS Series card Detailed Link OAM Status for Port 2: RemoteA: Remote Loopback Support
1.3.6.1.4.1.4756.20.731.20.1.454Columnf2000EASPort2LocalLMRemoteAread-onlycurrentf2000EAS Series card Detailed Link OAM Status for Port 2: RemoteA: Link Monitoring Support
1.3.6.1.4.1.4756.20.731.20.1.455Columnf2000EASPort2LocalMIBRetrievalRemoteAread-onlycurrentf2000EAS Series card Detailed Link OAM Status for Port 2: RemoteA: MIB Retrieval Support
1.3.6.1.4.1.4756.20.731.20.1.456Columnf2000EASPort2LocalMTUSizeRemoteAread-onlycurrentf2000EAS Series card Detailed Link OAM Status for Port 2: RemoteA: MTU Size
1.3.6.1.4.1.4756.20.731.20.1.457Columnf2000EASPort2LocalMultiStateRemoteAread-onlycurrentf2000EAS Series card Detailed Link OAM Status for Port 2: RemoteA: Multiplexer State
1.3.6.1.4.1.4756.20.731.20.1.458Columnf2000EASPort2LocalParserStateRemoteAread-onlycurrentf2000EAS Series card Detailed Link OAM Status for Port 2: RemoteA: Multiplexer State
1.3.6.1.4.1.4756.20.731.20.1.459Columnf2000EASPort2LocalOUIRemoteAread-onlycurrentf2000EAS Series card Detailed Link OAM Status for Port 2: RemoteA: Organizational Unique Identification
1.3.6.1.4.1.4756.20.731.20.1.460Columnf2000EASPort2LocalPDURevRemoteAread-onlycurrentf2000EAS Series card Detailed Link OAM Status for Port 2: RemoteA: PDU Revision
1.3.6.1.4.1.4756.20.731.20.1.461Columnf2000EASPort2PeerModeRemoteAread-onlycurrentf2000EAS Series card Detailed Link OAM Status for Port 2: Peer: Mode
1.3.6.1.4.1.4756.20.731.20.1.462Columnf2000EASPort2PeerUnOperationRemoteAread-onlycurrentf2000EAS Series card Detailed Link OAM Status for Port 2: Peer: Unidirectional Operation Support
1.3.6.1.4.1.4756.20.731.20.1.463Columnf2000EASPort2PeerRemoteLbRemoteAread-onlycurrentf2000EAS Series card Detailed Link OAM Status for Port 2: Peer: Remote Loopback Support
1.3.6.1.4.1.4756.20.731.20.1.464Columnf2000EASPort2PeerLMRemoteAread-onlycurrentf2000EAS Series card Detailed Link OAM Status for Port 2: Peer: Link Monitoring Support
1.3.6.1.4.1.4756.20.731.20.1.465Columnf2000EASPort2PeerMIBRetrievalRemoteAread-onlycurrentf2000EAS Series card Detailed Link OAM Status for Port 2: Peer: MIB Retrieval Support
1.3.6.1.4.1.4756.20.731.20.1.466Columnf2000EASPort2PeerMTUSizeRemoteAread-onlycurrentf2000EAS Series card Detailed Link OAM Status for Port 2: Peer: MTU Size
1.3.6.1.4.1.4756.20.731.20.1.467Columnf2000EASPort2PeerMultiStateRemoteAread-onlycurrentf2000EAS Series card Detailed Link OAM Status for Port 2: Peer: Multiplexer State
1.3.6.1.4.1.4756.20.731.20.1.468Columnf2000EASPort2PeerParserStateRemoteAread-onlycurrentf2000EAS Series card Detailed Link OAM Status for Port 2: Peer: Multiplexer State
1.3.6.1.4.1.4756.20.731.20.1.469Columnf2000EASPort2PeerOUIRemoteAread-onlycurrentf2000EAS Series card Detailed Link OAM Status for Port 2: Peer: Organizational Unique Identification
1.3.6.1.4.1.4756.20.731.20.1.470Columnf2000EASPort2PeerPDURevRemoteAread-onlycurrentf2000EAS Series card Detailed Link OAM Status for Port 2: Peer: PDU Revision
1.3.6.1.4.1.4756.20.731.20.1.471Columnf2000EASPort3PDUPermisionRemoteAread-onlycurrentf2000EAS Series card Detailed Link OAM Status for Port 3: PDU Permission
1.3.6.1.4.1.4756.20.731.20.1.472Columnf2000EASPort3DiscoveryStateRemoteAread-onlycurrentf2000EAS Series card Detailed Link OAM Status for Port 3: Discovery State
1.3.6.1.4.1.4756.20.731.20.1.473Columnf2000EASPort3PeerMACAddrRemoteAread-onlycurrentf2000EAS Series card Detailed Link OAM Status for Port 3: Discovery State
1.3.6.1.4.1.4756.20.731.20.1.474Columnf2000EASPort3LocalModeRemoteAread-onlycurrentf2000EAS Series card Detailed Link OAM Status for Port 3: RemoteA: Mode
1.3.6.1.4.1.4756.20.731.20.1.475Columnf2000EASPort3LocalUnOperationRemoteAread-onlycurrentf2000EAS Series card Detailed Link OAM Status for Port 3: RemoteA: Unidirectional Operation Support
1.3.6.1.4.1.4756.20.731.20.1.476Columnf2000EASPort3LocalRemoteLbRemoteAread-onlycurrentf2000EAS Series card Detailed Link OAM Status for Port 3: RemoteA: Remote Loopback Support
1.3.6.1.4.1.4756.20.731.20.1.477Columnf2000EASPort3LocalLMRemoteAread-onlycurrentf2000EAS Series card Detailed Link OAM Status for Port 3: RemoteA: Link Monitoring Support
1.3.6.1.4.1.4756.20.731.20.1.478Columnf2000EASPort3LocalMIBRetrievalRemoteAread-onlycurrentf2000EAS Series card Detailed Link OAM Status for Port 3: RemoteA: MIB Retrieval Support
1.3.6.1.4.1.4756.20.731.20.1.479Columnf2000EASPort3LocalMTUSizeRemoteAread-onlycurrentf2000EAS Series card Detailed Link OAM Status for Port 3: RemoteA: MTU Size
1.3.6.1.4.1.4756.20.731.20.1.480Columnf2000EASPort3LocalMultiStateRemoteAread-onlycurrentf2000EAS Series card Detailed Link OAM Status for Port 3: RemoteA: Multiplexer State
1.3.6.1.4.1.4756.20.731.20.1.481Columnf2000EASPort3LocalParserStateRemoteAread-onlycurrentf2000EAS Series card Detailed Link OAM Status for Port 3: RemoteA: Multiplexer State
1.3.6.1.4.1.4756.20.731.20.1.482Columnf2000EASPort3LocalOUIRemoteAread-onlycurrentf2000EAS Series card Detailed Link OAM Status for Port 3: RemoteA: Organizational Unique Identification
1.3.6.1.4.1.4756.20.731.20.1.483Columnf2000EASPort3LocalPDURevRemoteAread-onlycurrentf2000EAS Series card Detailed Link OAM Status for Port 3: RemoteA: PDU Revision
1.3.6.1.4.1.4756.20.731.20.1.484Columnf2000EASPort3PeerModeRemoteAread-onlycurrentf2000EAS Series card Detailed Link OAM Status for Port 3: Peer: Mode
1.3.6.1.4.1.4756.20.731.20.1.485Columnf2000EASPort3PeerUnOperationRemoteAread-onlycurrentf2000EAS Series card Detailed Link OAM Status for Port 3: Peer: Unidirectional Operation Support
1.3.6.1.4.1.4756.20.731.20.1.486Columnf2000EASPort3PeerRemoteLbRemoteAread-onlycurrentf2000EAS Series card Detailed Link OAM Status for Port 3: Peer: Remote Loopback Support
1.3.6.1.4.1.4756.20.731.20.1.487Columnf2000EASPort3PeerLMRemoteAread-onlycurrentf2000EAS Series card Detailed Link OAM Status for Port 3: Peer: Link Monitoring Support
1.3.6.1.4.1.4756.20.731.20.1.488Columnf2000EASPort3PeerMIBRetrievalRemoteAread-onlycurrentf2000EAS Series card Detailed Link OAM Status for Port 3: Peer: MIB Retrieval Support
1.3.6.1.4.1.4756.20.731.20.1.489Columnf2000EASPort3PeerMTUSizeRemoteAread-onlycurrentf2000EAS Series card Detailed Link OAM Status for Port 3: Peer: MTU Size
1.3.6.1.4.1.4756.20.731.20.1.490Columnf2000EASPort3PeerMultiStateRemoteAread-onlycurrentf2000EAS Series card Detailed Link OAM Status for Port 3: Peer: Multiplexer State
1.3.6.1.4.1.4756.20.731.20.1.491Columnf2000EASPort3PeerParserStateRemoteAread-onlycurrentf2000EAS Series card Detailed Link OAM Status for Port 3: Peer: Multiplexer State
1.3.6.1.4.1.4756.20.731.20.1.492Columnf2000EASPort3PeerOUIRemoteAread-onlycurrentf2000EAS Series card Detailed Link OAM Status for Port 3: Peer: Organizational Unique Identification
1.3.6.1.4.1.4756.20.731.20.1.493Columnf2000EASPort3PeerPDURevRemoteAread-onlycurrentf2000EAS Series card Detailed Link OAM Status for Port 3: Peer: PDU Revision
1.3.6.1.4.1.4756.20.731.20.1.494Columnf2000EASPort4PDUPermisionRemoteAread-onlycurrentf2000EAS Series card Detailed Link OAM Status for Port 4: PDU Permission
1.3.6.1.4.1.4756.20.731.20.1.495Columnf2000EASPort4DiscoveryStateRemoteAread-onlycurrentf2000EAS Series card Detailed Link OAM Status for Port 4: Discovery State
1.3.6.1.4.1.4756.20.731.20.1.496Columnf2000EASPort4PeerMACAddrRemoteAread-onlycurrentf2000EAS Series card Detailed Link OAM Status for Port 4: Discovery State
1.3.6.1.4.1.4756.20.731.20.1.497Columnf2000EASPort4LocalModeRemoteAread-onlycurrentf2000EAS Series card Detailed Link OAM Status for Port 4: RemoteA: Mode
1.3.6.1.4.1.4756.20.731.20.1.498Columnf2000EASPort4LocalUnOperationRemoteAread-onlycurrentf2000EAS Series card Detailed Link OAM Status for Port 4: RemoteA: Unidirectional Operation Support
1.3.6.1.4.1.4756.20.731.20.1.499Columnf2000EASPort4LocalRemoteLbRemoteAread-onlycurrentf2000EAS Series card Detailed Link OAM Status for Port 4: RemoteA: Remote Loopback Support
1.3.6.1.4.1.4756.20.731.20.1.500Columnf2000EASPort4LocalLMRemoteAread-onlycurrentf2000EAS Series card Detailed Link OAM Status for Port 4: RemoteA: Link Monitoring Support
1.3.6.1.4.1.4756.20.731.20.1.501Columnf2000EASPort4LocalMIBRetrievalRemoteAread-onlycurrentf2000EAS Series card Detailed Link OAM Status for Port 4: RemoteA: MIB Retrieval Support
1.3.6.1.4.1.4756.20.731.20.1.502Columnf2000EASPort4LocalMTUSizeRemoteAread-onlycurrentf2000EAS Series card Detailed Link OAM Status for Port 4: RemoteA: MTU Size
1.3.6.1.4.1.4756.20.731.20.1.503Columnf2000EASPort4LocalMultiStateRemoteAread-onlycurrentf2000EAS Series card Detailed Link OAM Status for Port 4: RemoteA: Multiplexer State
1.3.6.1.4.1.4756.20.731.20.1.504Columnf2000EASPort4LocalParserStateRemoteAread-onlycurrentf2000EAS Series card Detailed Link OAM Status for Port 4: RemoteA: Multiplexer State
1.3.6.1.4.1.4756.20.731.20.1.505Columnf2000EASPort4LocalOUIRemoteAread-onlycurrentf2000EAS Series card Detailed Link OAM Status for Port 4: RemoteA: Organizational Unique Identification
1.3.6.1.4.1.4756.20.731.20.1.506Columnf2000EASPort4LocalPDURevRemoteAread-onlycurrentf2000EAS Series card Detailed Link OAM Status for Port 4: RemoteA: PDU Revision
1.3.6.1.4.1.4756.20.731.20.1.507Columnf2000EASPort4PeerModeRemoteAread-onlycurrentf2000EAS Series card Detailed Link OAM Status for Port 4: Peer: Mode
1.3.6.1.4.1.4756.20.731.20.1.508Columnf2000EASPort4PeerUnOperationRemoteAread-onlycurrentf2000EAS Series card Detailed Link OAM Status for Port 4: Peer: Unidirectional Operation Support
1.3.6.1.4.1.4756.20.731.20.1.509Columnf2000EASPort4PeerRemoteLbRemoteAread-onlycurrentf2000EAS Series card Detailed Link OAM Status for Port 4: Peer: Remote Loopback Support
1.3.6.1.4.1.4756.20.731.20.1.510Columnf2000EASPort4PeerLMRemoteAread-onlycurrentf2000EAS Series card Detailed Link OAM Status for Port 4: Peer: Link Monitoring Support
1.3.6.1.4.1.4756.20.731.20.1.511Columnf2000EASPort4PeerMIBRetrievalRemoteAread-onlycurrentf2000EAS Series card Detailed Link OAM Status for Port 4: Peer: MIB Retrieval Support
1.3.6.1.4.1.4756.20.731.20.1.512Columnf2000EASPort4PeerMTUSizeRemoteAread-onlycurrentEDD Series card Detailed Link OAM Status for Port 4: Peer: MTU Size
1.3.6.1.4.1.4756.20.731.20.1.513Columnf2000EASPort4PeerMultiStateRemoteAread-onlycurrentf2000EAS Series card Detailed Link OAM Status for Port 4: Peer: Multiplexer State
1.3.6.1.4.1.4756.20.731.20.1.514Columnf2000EASPort4PeerParserStateRemoteAread-onlycurrentf2000EAS Series card Detailed Link OAM Status for Port 4: Peer: Multiplexer State
1.3.6.1.4.1.4756.20.731.20.1.515Columnf2000EASPort4PeerOUIRemoteAread-onlycurrentf2000EAS Series card Detailed Link OAM Status for Port 4: Peer: Organizational Unique Identification
1.3.6.1.4.1.4756.20.731.20.1.516Columnf2000EASPort4PeerPDURevRemoteAread-onlycurrentf2000EAS Series card Detailed Link OAM Status for Port 4: Peer: PDU Revision
1.3.6.1.4.1.4756.20.731.20.1.517Columnf2000EASCLEAROAMCOUNTERRemoteAread-writecurrentf2000EAS Series card Clear OAM Counter: 0: Off 1: Action
1.3.6.1.4.1.4756.20.731.20.1.518Columnf2000EASLoopProtectionEnableRemoteAread-writecurrentf2000EAS Series card Loop Protection Configuration: General Settings - Enable Loop Protection 0: Disable 1: Enable
1.3.6.1.4.1.4756.20.731.20.1.519Columnf2000EASLoopProtectionTxTimeRemoteAread-writecurrentf2000EAS Series card Loop Protection Configuration: General Settings - Transmission Time
1.3.6.1.4.1.4756.20.731.20.1.520Columnf2000EASLoopProtectionShutdownTimeRemoteAread-writecurrentf2000EAS Series card Loop Protection Configuration: General Settings - Shutdown Time
1.3.6.1.4.1.4756.20.731.20.1.521Columnf2000EASLoopProtectionPort1EnabledRemoteAread-writecurrentf2000EAS Series card Loop Protection Configuration for Port 1: Port Configuration - Enable 0: Disable 1: Enable
1.3.6.1.4.1.4756.20.731.20.1.522Columnf2000EASLoopProtectionPort1ActionRemoteAread-writecurrentf2000EAS Series card Loop Protection Configuration for Port 1: Port Configuration - Action 0: Shutdown Port 1: Shutdown Port And Log 2: Log Only
1.3.6.1.4.1.4756.20.731.20.1.523Columnf2000EASLoopProtectionPort1TxModeRemoteAread-writecurrentf2000EAS Series card Loop Protection Configuration for Port 1: Port Configuration - Tx Mode 0: Disable 1: Enable
1.3.6.1.4.1.4756.20.731.20.1.524Columnf2000EASLoopProtectionPort2EnabledRemoteAread-writecurrentf2000EAS Series card Loop Protection Configuration for Port 2: Port Configuration - Enable 0: Disable 1: Enable
1.3.6.1.4.1.4756.20.731.20.1.525Columnf2000EASLoopProtectionPort2ActionRemoteAread-writecurrentf2000EAS Series card Loop Protection Configuration for Port 2: Port Configuration - Action 0: Shutdown Port 1: Shutdown Port And Log 2: Log Only
1.3.6.1.4.1.4756.20.731.20.1.526Columnf2000EASLoopProtectionPort2TxModeRemoteAread-writecurrentf2000EAS Series card Loop Protection Configuration for Port 2: Port Configuration - Tx Mode 0: Disable 1: Enable
1.3.6.1.4.1.4756.20.731.20.1.527Columnf2000EASLoopProtectionPort3EnabledRemoteAread-writecurrentf2000EASE Series card Loop Protection Configuration for Port 3: Port Configuration - Enable 0: Disable 1: Enable
1.3.6.1.4.1.4756.20.731.20.1.528Columnf2000EASLoopProtectionPort3ActionRemoteAread-writecurrentf2000EAS Series card Loop Protection Configuration for Port 3: Port Configuration - Action 0: Shutdown Port 1: Shutdown Port And Log 2: Log Only
1.3.6.1.4.1.4756.20.731.20.1.529Columnf2000EASLoopProtectionPort3TxModeRemoteAread-writecurrentf2000EAS Series card Loop Protection Configuration for Port 3: Port Configuration - Tx Mode 0: Disable 1: Enable
1.3.6.1.4.1.4756.20.731.20.1.530Columnf2000EASLoopProtectionPort4EnabledRemoteAread-writecurrentf2000EAS Series card Loop Protection Configuration for Port 4: Port Configuration - Enable 0: Disable 1: Enable
1.3.6.1.4.1.4756.20.731.20.1.531Columnf2000EASLoopProtectionPort4ActionRemoteAread-writecurrentf2000EAS Series card Loop Protection Configuration for Port 4: Port Configuration - Action 0: Shutdown Port 1: Shutdown Port And Log 2: Log Only
1.3.6.1.4.1.4756.20.731.20.1.532Columnf2000EASLoopProtectionPort4TxModeRemoteAread-writecurrentf2000EAS Series card Loop Protection Configuration for Port 41: Port Configuration - Tx Mode 0: Disable 1: Enable
1.3.6.1.4.1.4756.20.731.20.1.533Columnf2000EASLoopProtectionPort1ActionStsRemoteAread-onlycurrentf2000EAS Series card Loop Protection Status for Port 1: Action
1.3.6.1.4.1.4756.20.731.20.1.534Columnf2000EASLoopProtectionPort1TransStsRemoteAread-onlycurrentf2000EAS Series card Loop Protection Status for Port 1: Transmit
1.3.6.1.4.1.4756.20.731.20.1.535Columnf2000EASLoopProtectionPort1LoopsStsRemoteAread-onlycurrentf2000EAS Series card Loop Protection Status for Port 1: Loops
1.3.6.1.4.1.4756.20.731.20.1.536Columnf2000EASLoopProtectionPort1StatusRemoteAread-onlycurrentf2000EAS Series card Loop Protection Status for Port 1: Status
1.3.6.1.4.1.4756.20.731.20.1.537Columnf2000EASLoopProtectionPort1LoopStsRemoteAread-onlycurrentf2000EAS Series card Loop Protection Status for Port 1: Loop
1.3.6.1.4.1.4756.20.731.20.1.538Columnf2000EASLoopProtectionPort2ActionStsRemoteAread-onlycurrentf2000EAS Series card Loop Protection Status for Port 2: Action
1.3.6.1.4.1.4756.20.731.20.1.539Columnf2000EASLoopProtectionPort2TransStsRemoteAread-onlycurrentf2000EAS Series card Loop Protection Status for Port 2: Transmit
1.3.6.1.4.1.4756.20.731.20.1.540Columnf2000EASLoopProtectionPort2LoopsStsRemoteAread-onlycurrentf2000EAS Series card Loop Protection Status for Port 2: Loops
1.3.6.1.4.1.4756.20.731.20.1.541Columnf2000EASLoopProtectionPort2StatusRemoteAread-onlycurrentf2000EAS Series card Loop Protection Status for Port 2: Status
1.3.6.1.4.1.4756.20.731.20.1.542Columnf2000EASLoopProtectionPort2LoopStsRemoteAread-onlycurrentf2000EAS Series card Loop Protection Status for Port 2: Loop
1.3.6.1.4.1.4756.20.731.20.1.543Columnf2000EASLoopProtectionPort3ActionStsRemoteAread-onlycurrentf2000EAS Series card Loop Protection Status for Port 3: Action
1.3.6.1.4.1.4756.20.731.20.1.544Columnf2000EASLoopProtectionPort3TransStsRemoteAread-onlycurrentf2000EAS Series card Loop Protection Status for Port 3: Transmit
1.3.6.1.4.1.4756.20.731.20.1.545Columnf2000EASLoopProtectionPort3LoopsStsRemoteAread-onlycurrentf2000EAS Series card Loop Protection Status for Port 3: Loops
1.3.6.1.4.1.4756.20.731.20.1.546Columnf2000EASLoopProtectionPort3StatusRemoteAread-onlycurrentf2000EAS Series card Loop Protection Status for Port 3: Status
1.3.6.1.4.1.4756.20.731.20.1.547Columnf2000EASLoopProtectionPort3LoopStsRemoteAread-onlycurrentf2000EAS Series card Loop Protection Status for Port 3: Loop
1.3.6.1.4.1.4756.20.731.20.1.548Columnf2000EASLoopProtectionPort4ActionStsRemoteAread-onlycurrentf2000EAS Series card Loop Protection Status for Port 4: Action
1.3.6.1.4.1.4756.20.731.20.1.549Columnf2000EASLoopProtectionPort4TransStsRemoteAread-onlycurrentf2000EAS Series card Loop Protection Status for Port 4: Transmit
1.3.6.1.4.1.4756.20.731.20.1.550Columnf2000EASLoopProtectionPort4LoopsStsRemoteAread-onlycurrentf2000EAS Series card Loop Protection Status for Port 4: Loops
1.3.6.1.4.1.4756.20.731.20.1.551Columnf2000EASLoopProtectionPort4StatusRemoteAread-onlycurrentf2000EAS Series card Loop Protection Status for Port 4: Status
1.3.6.1.4.1.4756.20.731.20.1.552Columnf2000EASLoopProtectionPort4LoopStsRemoteAread-onlycurrentf2000EAS Series card Loop Protection Status for Port 4: Loop
1.3.6.1.4.1.4756.20.731.20.1.553Columnf2000EASSTPProtocolVersionRemoteAread-writecurrentf2000EAS Series card STP Bridge Configuration: Basic Settings - Protocol Version 0: STP 1: RSTP 2: MSTP
1.3.6.1.4.1.4756.20.731.20.1.554Columnf2000EASSTPBridgePriorityRemoteAread-writecurrentf2000EAS Series card STP Bridge Configuration: Basic Settings - Bridge Priority 0: 0 1: 4096 2: 8192 3: 12288 4: 16384 5: 20480 6: 24576 7: 28672 8: 32768 9: 3…
1.3.6.1.4.1.4756.20.731.20.1.555Columnf2000EASSTPForwardDelayRemoteAread-writecurrentf2000EAS Series card STP Bridge Configuration: Basic Settings - Forward Delay
1.3.6.1.4.1.4756.20.731.20.1.556Columnf2000EASSTPMaxAgeRemoteAread-writecurrentf2000EAS Series card STP Bridge Configuration: Basic Settings - Max Age
1.3.6.1.4.1.4756.20.731.20.1.557Columnf2000EASSTPMaximumHopCountRemoteAread-writecurrentf2000EAS Series card STP Bridge Configuration: Basic Settings - Maximum Hop Count
1.3.6.1.4.1.4756.20.731.20.1.558Columnf2000EASSTPTransmitHoldCountRemoteAread-writecurrentf2000EAS Series card STP Bridge Configuration: Basic Settings - Transmit Hold Count
1.3.6.1.4.1.4756.20.731.20.1.559Columnf2000EASSTPEdgePortBPDUFilteringRemoteAread-writecurrentf2000EAS Series card STP Bridge Configuration: Advanced Settings - Edge Port BPDU Filtering 0: Off 1: On
1.3.6.1.4.1.4756.20.731.20.1.560Columnf2000EASSTPEdgePortBPDUGuardRemoteAread-writecurrentf2000EAS Series card STP Bridge Configuration: Advanced Settings - Edge Port BPDU Guard 0: Off 1: On
1.3.6.1.4.1.4756.20.731.20.1.561Columnf2000EASSTPPortErrorRecoveryTimeoutRemoteAread-writecurrentf2000EAS Series card STP Bridge Configuration: Advanced Settings - Port Error Recovery Timeout 0: Off 1: On
1.3.6.1.4.1.4756.20.731.20.1.562Columnf2000EASMSTIConfigurationNameRemoteAread-writecurrentf2000EAS Series card MSTI Configuration: Configuration Identification - Configuration Name
1.3.6.1.4.1.4756.20.731.20.1.563Columnf2000EASMSTIConfigurationRevisionRemoteAread-writecurrentf2000EAS Series card MSTI Configuration: Configuration Identification - Configuration Revision
1.3.6.1.4.1.4756.20.731.20.1.564Columnf2000EASMSTI1VLANsMappingRemoteAread-writecurrentf2000EAS Series card MSTI Configuration: MSTI Mapping - MSTI 1
1.3.6.1.4.1.4756.20.731.20.1.565Columnf2000EASMSTI2VLANsMappingRemoteAread-writecurrentf2000EAS Series card MSTI Configuration: MSTI Mapping - MSTI 2
1.3.6.1.4.1.4756.20.731.20.1.566Columnf2000EASMSTI3VLANsMappingRemoteAread-writecurrentf2000EAS Series card MSTI Configuration: MSTI Mapping - MSTI 3
1.3.6.1.4.1.4756.20.731.20.1.567Columnf2000EASMSTI4VLANsMappingRemoteAread-writecurrentf2000EAS Series card MSTI Configuration: MSTI Mapping - MSTI 4
1.3.6.1.4.1.4756.20.731.20.1.568Columnf2000EASMSTI5VLANsMappingRemoteAread-writecurrentf2000EAS Series card MSTI Configuration: MSTI Mapping - MSTI 5
1.3.6.1.4.1.4756.20.731.20.1.569Columnf2000EASMSTI6VLANsMappingRemoteAread-writecurrentf2000EAS Series card MSTI Configuration: MSTI Mapping - MSTI 6
1.3.6.1.4.1.4756.20.731.20.1.570Columnf2000EASMSTI7VLANsMappingRemoteAread-writecurrentf2000EAS Series card MSTI Configuration: MSTI Mapping - MSTI 7
1.3.6.1.4.1.4756.20.731.20.1.571Columnf2000EASCISTAggregatedSTPEnabledRemoteAread-writecurrentf2000EAS Series card STP CIST Port Configuration: CIST Aggregated Port Configuration - STP Enabled
1.3.6.1.4.1.4756.20.731.20.1.572Columnf2000EASCISTAggregatedPathCostRemoteAread-writecurrentf2000EAS Series card STP CIST Port Configuration: CIST Aggregated Port Configuration - Path Cost Valid values are in the range 0 to 200000000. Setting 0 means …
1.3.6.1.4.1.4756.20.731.20.1.573Columnf2000EASCISTAggregatedPriorityRemoteAread-writecurrentf2000EAS Series card STP CIST Port Configuration: CIST Aggregated Port Configuration - Priority
1.3.6.1.4.1.4756.20.731.20.1.574Columnf2000EASCISTAggregatedAdminEdgeRemoteAread-writecurrentf2000EAS Series card STP CIST Port Configuration: CIST Aggregated Port Configuration - STP Enabled 0: Non-edge 1: Edge
1.3.6.1.4.1.4756.20.731.20.1.575Columnf2000EASCISTAggregatedAutoEdgeRemoteAread-writecurrentf2000EAS Series card STP CIST Port Configuration: CIST Aggregated Port Configuration - Auto Edge 0: Non-edge 1: Edge
1.3.6.1.4.1.4756.20.731.20.1.576Columnf2000EASCISTAggregatedRestrictedRoleRemoteAread-writecurrentf2000EAS Series card STP CIST Port Configuration: CIST Aggregated Port Configuration - Restricted Role 0: Non-edge 1: Edge
1.3.6.1.4.1.4756.20.731.20.1.577Columnf2000EASCISTAggregatedRestrictedTCNRemoteAread-writecurrentf2000EAS Series card STP CIST Port Configuration: CIST Aggregated Port Configuration - Restricted TCN 0: Non-edge 1: Edge
1.3.6.1.4.1.4756.20.731.20.1.578Columnf2000EASCISTAggregatedBPDUGuardRemoteAread-writecurrentf2000EAS Series card STP CIST Port Configuration: CIST Aggregated Port Configuration - BPDU Guard 0: Non-edge 1: Edge
1.3.6.1.4.1.4756.20.731.20.1.579Columnf2000EASCISTAggregatedPointToPointRemoteAread-writecurrentf2000EAS Series card STP CIST Port Configuration: CIST Aggregated Port Configuration - Point-to-point 0: Forced True 1: Forced False 2: Auto
1.3.6.1.4.1.4756.20.731.20.1.580Columnf2000EASCISTPort1STPEnabledRemoteAread-writecurrentf2000EAS Series card STP CIST Port Configuration: CIST Normal Port1 Configuration - STP Enabled
1.3.6.1.4.1.4756.20.731.20.1.581Columnf2000EASCISTPort1PathCostRemoteAread-writecurrentf2000EAS Series card STP CIST Port Configuration: CIST Normal Port1 Configuration - Path Cost Valid values are in the range 0 to 200000000. Setting 0 means Aut…
1.3.6.1.4.1.4756.20.731.20.1.582Columnf2000EASCISTPort1PriorityRemoteAread-writecurrentf2000EAS Series card STP CIST Port Configuration: CIST Normal Port1 Configuration - Priority
1.3.6.1.4.1.4756.20.731.20.1.583Columnf2000EASCISTPort1AdminEdgeRemoteAread-writecurrentf2000EAS Series card STP CIST Port Configuration: CIST Normal Port1 Configuration - STP Enabled 0: Non-edge 1: Edge
1.3.6.1.4.1.4756.20.731.20.1.584Columnf2000EASCISTPort1AutoEdgeRemoteAread-writecurrentf2000EAS Series card STP CIST Port Configuration: CIST Normal Port1 Configuration - Auto Edge 0: Non-edge 1: Edge
1.3.6.1.4.1.4756.20.731.20.1.585Columnf2000EASCISTPort1RestrictedRoleRemoteAread-writecurrentf2000EAS Series card STP CIST Port Configuration: CIST Normal Port1 Configuration - Restricted Role 0: Non-edge 1: Edge
1.3.6.1.4.1.4756.20.731.20.1.586Columnf2000EASCISTPort1RestrictedTCNRemoteAread-writecurrentf2000EAS Series card STP CIST Port Configuration: CIST Normal Port1 Configuration - Restricted TCN 0: Non-edge 1: Edge
1.3.6.1.4.1.4756.20.731.20.1.587Columnf2000EASCISTPort1BPDUGuardRemoteAread-writecurrentf2000EAS Series card STP CIST Port Configuration: CIST Normal Port1 Configuration - BPDU Guard 0: Non-edge 1: Edge
1.3.6.1.4.1.4756.20.731.20.1.588Columnf2000EASCISTPort1PointToPointRemoteAread-writecurrentf2000EAS Series card STP CIST Port Configuration: CIST Normal Port1 Configuration - Point-to-point 0: Forced True 1: Forced False 2: Auto
1.3.6.1.4.1.4756.20.731.20.1.589Columnf2000EASCISTPort2STPEnabledRemoteAread-writecurrentf2000EAS Series card STP CIST Port Configuration: CIST Normal Port2 Configuration - STP Enabled
1.3.6.1.4.1.4756.20.731.20.1.590Columnf2000EASCISTPort2PathCostRemoteAread-writecurrentf2000EAS Series card STP CIST Port Configuration: CIST Normal Port2 Configuration - Path Cost Valid values are in the range 0 to 200000000. Setting 0 means Aut…
1.3.6.1.4.1.4756.20.731.20.1.591Columnf2000EASCISTPort2PriorityRemoteAread-writecurrentf2000EAS Series card STP CIST Port Configuration: CIST Normal Port2 Configuration - Priority
1.3.6.1.4.1.4756.20.731.20.1.592Columnf2000EASCISTPort2AdminEdgeRemoteAread-writecurrentf2000EAS Series card STP CIST Port Configuration: CIST Normal Port2 Configuration - STP Enabled 0: Non-edge 1: Edge
1.3.6.1.4.1.4756.20.731.20.1.593Columnf2000EASCISTPort2AutoEdgeRemoteAread-writecurrentf2000EAS Series card STP CIST Port Configuration: CIST Normal Port2 Configuration - Auto Edge 0: Non-edge 1: Edge
1.3.6.1.4.1.4756.20.731.20.1.594Columnf2000EASCISTPort2RestrictedRoleRemoteAread-writecurrentf2000EAS Series card STP CIST Port Configuration: CIST Normal Port2 Configuration - Restricted Role 0: Non-edge 1: Edge
1.3.6.1.4.1.4756.20.731.20.1.595Columnf2000EASCISTPort2RestrictedTCNRemoteAread-writecurrentf2000EAS Series card STP CIST Port Configuration: CIST Normal Port2 Configuration - Restricted TCN 0: Non-edge 1: Edge
1.3.6.1.4.1.4756.20.731.20.1.596Columnf2000EASCISTPort2BPDUGuardRemoteAread-writecurrentf2000EAS Series card STP CIST Port Configuration: CIST Normal Port2 Configuration - BPDU Guard 0: Non-edge 1: Edge
1.3.6.1.4.1.4756.20.731.20.1.597Columnf2000EASCISTPort2PointToPointRemoteAread-writecurrentf2000EAS Series card STP CIST Port Configuration: CIST Normal Port2 Configuration - Point-to-point 0: Forced True 1: Forced False 2: Auto
1.3.6.1.4.1.4756.20.731.20.1.598Columnf2000EASCISTPort3STPEnabledRemoteAread-writecurrentf2000EAS Series card STP CIST Port Configuration: CIST Normal Port3 Configuration - STP Enabled
1.3.6.1.4.1.4756.20.731.20.1.599Columnf2000EASCISTPort3PathCostRemoteAread-writecurrentf2000EAS Series card STP CIST Port Configuration: CIST Normal Port3 Configuration - Path Cost Valid values are in the range 0 to 200000000. Setting 0 means Aut…
1.3.6.1.4.1.4756.20.731.20.1.600Columnf2000EASCISTPort3PriorityRemoteAread-writecurrentf2000EAS Series card STP CIST Port Configuration: CIST Normal Port3 Configuration - Priority
1.3.6.1.4.1.4756.20.731.20.1.601Columnf2000EASCISTPort3AdminEdgeRemoteAread-writecurrentf2000EAS Series card STP CIST Port Configuration: CIST Normal Port3 Configuration - STP Enabled 0: Non-edge 1: Edge
1.3.6.1.4.1.4756.20.731.20.1.602Columnf2000EASCISTPort3AutoEdgeRemoteAread-writecurrentf2000EAS Series card STP CIST Port Configuration: CIST Normal Port3 Configuration - Auto Edge 0: Non-edge 1: Edge
1.3.6.1.4.1.4756.20.731.20.1.603Columnf2000EASCISTPort3RestrictedRoleRemoteAread-writecurrentf2000EAS Series card STP CIST Port Configuration: CIST Normal Port3 Configuration - Restricted Role 0: Non-edge 1: Edge
1.3.6.1.4.1.4756.20.731.20.1.604Columnf2000EASCISTPort3RestrictedTCNRemoteAread-writecurrentf2000EAS Series card STP CIST Port Configuration: CIST Normal Port3 Configuration - Restricted TCN 0: Non-edge 1: Edge
1.3.6.1.4.1.4756.20.731.20.1.605Columnf2000EASCISTPort3BPDUGuardRemoteAread-writecurrentf2000EAS Series card STP CIST Port Configuration: CIST Normal Port3 Configuration - BPDU Guard 0: Non-edge 1: Edge
1.3.6.1.4.1.4756.20.731.20.1.606Columnf2000EASCISTPort3PointToPointRemoteAread-writecurrentf2000EAS Series card STP CIST Port Configuration: CIST Normal Port3 Configuration - Point-to-point 0: Forced True 1: Forced False 2: Auto
1.3.6.1.4.1.4756.20.731.20.1.607Columnf2000EASCISTPort4STPEnabledRemoteAread-writecurrentf2000EAS Series card STP CIST Port Configuration: CIST Normal Port4 Configuration - STP Enabled
1.3.6.1.4.1.4756.20.731.20.1.608Columnf2000EASCISTPort4PathCostRemoteAread-writecurrentf2000EAS Series card STP CIST Port Configuration: CIST Normal Port4 Configuration - Path Cost Valid values are in the range 0 to 200000000. Setting 0 means Aut…
1.3.6.1.4.1.4756.20.731.20.1.609Columnf2000EASCISTPort4PriorityRemoteAread-writecurrentf2000EAS Series card STP CIST Port Configuration: CIST Normal Port4 Configuration - Priority
1.3.6.1.4.1.4756.20.731.20.1.610Columnf2000EASCISTPort4AdminEdgeRemoteAread-writecurrentf2000EAS Series card STP CIST Port Configuration: CIST Normal Port4 Configuration - STP Enabled 0: Non-edge 1: Edge
1.3.6.1.4.1.4756.20.731.20.1.611Columnf2000EASCISTPort4AutoEdgeRemoteAread-writecurrentf2000EAS Series card STP CIST Port Configuration: CIST Normal Port4 Configuration - Auto Edge 0: Non-edge 1: Edge
1.3.6.1.4.1.4756.20.731.20.1.612Columnf2000EASCISTPort4RestrictedRoleRemoteAread-writecurrentf2000EAS Series card STP CIST Port Configuration: CIST Normal Port4 Configuration - Restricted Role 0: Non-edge 1: Edge
1.3.6.1.4.1.4756.20.731.20.1.613Columnf2000EASCISTPort4RestrictedTCNRemoteAread-writecurrentf2000EAS Series card STP CIST Port Configuration: CIST Normal Port4 Configuration - Restricted TCN 0: Non-edge 1: Edge
1.3.6.1.4.1.4756.20.731.20.1.614Columnf2000EASCISTPort4BPDUGuardRemoteAread-writecurrentf2000EAS Series card STP CIST Port Configuration: CIST Normal Port4 Configuration - BPDU Guard 0: Non-edge 1: Edge
1.3.6.1.4.1.4756.20.731.20.1.615Columnf2000EASCISTPort4PointToPointRemoteAread-writecurrentf2000EAS Series card STP CIST Port Configuration: CIST Normal Port4 Configuration - Point-to-point 0: Forced True 1: Forced False 2: Auto
1.3.6.1.4.1.4756.20.731.20.1.616Columnf2000EASMSTI1AggregatedPathCostRemoteAread-writecurrentf2000EAS Series card MSTI Port Configuration: MSTI1 Aggregated Ports Configuration - Path Cost Valid values are in the range 0 to 200000000. Setting 0 means Au…
1.3.6.1.4.1.4756.20.731.20.1.617Columnf2000EASMSTI1AggregatedPriorityRemoteAread-writecurrentf2000EAS Series card MSTI Port Configuration: MSTI1 Aggregated Ports Configuration - Priority
1.3.6.1.4.1.4756.20.731.20.1.618Columnf2000EASMSTI1Port1PathCostRemoteAread-writecurrentf2000EAS Series card MSTI Port Configuration: MSTI1 Normal Port1 Configuration - Path Cost Valid values are in the range 0 to 200000000. Setting 0 means Auto p…
1.3.6.1.4.1.4756.20.731.20.1.619Columnf2000EASMSTI1Port1PriorityRemoteAread-writecurrentf2000EAS Series card MSTI Port Configuration: MSTI1 Normal Port1 Configuration - Priority
1.3.6.1.4.1.4756.20.731.20.1.620Columnf2000EASMSTI1Port2PathCostRemoteAread-writecurrentf2000EAS Series card MSTI Port Configuration: MSTI1 Normal Port2 Configuration - Path Cost Valid values are in the range 0 to 200000000. Setting 0 means Auto p…
1.3.6.1.4.1.4756.20.731.20.1.621Columnf2000EASMSTI1Port2PriorityRemoteAread-writecurrentf2000EAS Series card MSTI Port Configuration: MSTI1 Normal Port2 Configuration - Priority
1.3.6.1.4.1.4756.20.731.20.1.622Columnf2000EASMSTI1Port3PathCostRemoteAread-writecurrentf2000EAS Series card MSTI Port Configuration: MSTI1 Normal Port3 Configuration - Path Cost Valid values are in the range 0 to 200000000. Setting 0 means Auto p…
1.3.6.1.4.1.4756.20.731.20.1.623Columnf2000EASMSTI1Port3PriorityRemoteAread-writecurrentf2000EAS Series card MSTI Port Configuration: MSTI1 Normal Port3 Configuration - Priority
1.3.6.1.4.1.4756.20.731.20.1.624Columnf2000EASMSTI1Port4PathCostRemoteAread-writecurrentf2000EAS Series card MSTI Port Configuration: MSTI1 Normal Port4 Configuration - Path Cost Valid values are in the range 0 to 200000000. Setting 0 means Auto p…
1.3.6.1.4.1.4756.20.731.20.1.625Columnf2000EASMSTI1Port4PriorityRemoteAread-writecurrentf2000EAS Series card MSTI Port Configuration: MSTI1 Normal Port4 Configuration - Priority
1.3.6.1.4.1.4756.20.731.20.1.626Columnf2000EASMSTI2AggregatedPathCostRemoteAread-writecurrentf2000EAS Series card MSTI Port Configuration: MSTI2 Aggregated Ports Configuration - Path Cost Valid values are in the range 0 to 200000000. Setting 0 means Au…
1.3.6.1.4.1.4756.20.731.20.1.627Columnf2000EASMSTI2AggregatedPriorityRemoteAread-writecurrentf2000EAS Series card MSTI Port Configuration: MSTI2 Aggregated Ports Configuration - Priority
1.3.6.1.4.1.4756.20.731.20.1.628Columnf2000EASMSTI2Port1PathCostRemoteAread-writecurrentf2000EAS Series card MSTI Port Configuration: MSTI2 Normal Port1 Configuration - Path Cost Valid values are in the range 0 to 200000000. Setting 0 means Auto p…
1.3.6.1.4.1.4756.20.731.20.1.629Columnf2000EASMSTI2Port1PriorityRemoteAread-writecurrentf2000EAS Series card MSTI Port Configuration: MSTI2 Normal Port1 Configuration - Priority
1.3.6.1.4.1.4756.20.731.20.1.630Columnf2000EASMSTI2Port2PathCostRemoteAread-writecurrentf2000EAS Series card MSTI Port Configuration: MSTI2 Normal Port2 Configuration - Path Cost Valid values are in the range 0 to 200000000. Setting 0 means Auto p…
1.3.6.1.4.1.4756.20.731.20.1.631Columnf2000EASMSTI2Port2PriorityRemoteAread-writecurrentf2000EAS Series card MSTI Port Configuration: MSTI2 Normal Port2 Configuration - Priority
1.3.6.1.4.1.4756.20.731.20.1.632Columnf2000EASMSTI2Port3PathCostRemoteAread-writecurrentf2000EAS Series card MSTI Port Configuration: MSTI2 Normal Port3 Configuration - Path Cost Valid values are in the range 0 to 200000000. Setting 0 means Auto p…
1.3.6.1.4.1.4756.20.731.20.1.633Columnf2000EASMSTI2Port3PriorityRemoteAread-writecurrentf2000EAS Series card MSTI Port Configuration: MSTI2 Normal Port3 Configuration - Priority
1.3.6.1.4.1.4756.20.731.20.1.634Columnf2000EASMSTI2Port4PathCostRemoteAread-writecurrentf2000EAS Series card MSTI Port Configuration: MSTI2 Normal Port4 Configuration - Path Cost Valid values are in the range 0 to 200000000. Setting 0 means Auto p…
1.3.6.1.4.1.4756.20.731.20.1.635Columnf2000EASMSTI2Port4PriorityRemoteAread-writecurrentf2000EAS Series card MSTI Port Configuration: MSTI2 Normal Port4 Configuration - Priority
1.3.6.1.4.1.4756.20.731.20.1.636Columnf2000EASMSTI3AggregatedPathCostRemoteAread-writecurrentf2000EAS Series card MSTI Port Configuration: MSTI3 Aggregated Ports Configuration - Path Cost Valid values are in the range 0 to 200000000. Setting 0 means Au…
1.3.6.1.4.1.4756.20.731.20.1.637Columnf2000EASMSTI3AggregatedPriorityRemoteAread-writecurrentf2000EAS Series card MSTI Port Configuration: MSTI3 Aggregated Ports Configuration - Priority
1.3.6.1.4.1.4756.20.731.20.1.638Columnf2000EASMSTI3Port1PathCostRemoteAread-writecurrentf2000EAS Series card MSTI Port Configuration: MSTI3 Normal Port1 Configuration - Path Cost Valid values are in the range 0 to 200000000. Setting 0 means Auto p…
1.3.6.1.4.1.4756.20.731.20.1.639Columnf2000EASMSTI3Port1PriorityRemoteAread-writecurrentf2000EAS Series card MSTI Port Configuration: MSTI3 Normal Port1 Configuration - Priority
1.3.6.1.4.1.4756.20.731.20.1.640Columnf2000EASMSTI3Port2PathCostRemoteAread-writecurrentf2000EAS Series card MSTI Port Configuration: MSTI3 Normal Port2 Configuration - Path Cost Valid values are in the range 0 to 200000000. Setting 0 means Auto p…
1.3.6.1.4.1.4756.20.731.20.1.641Columnf2000EASMSTI3Port2PriorityRemoteAread-writecurrentf2000EAS Series card MSTI Port Configuration: MSTI3 Normal Port2 Configuration - Priority
1.3.6.1.4.1.4756.20.731.20.1.642Columnf2000EASMSTI3Port3PathCostRemoteAread-writecurrentf2000EAS Series card MSTI Port Configuration: MSTI1 Normal Port3 Configuration - Path Cost Valid values are in the range 0 to 200000000. Setting 0 means Auto p…
1.3.6.1.4.1.4756.20.731.20.1.643Columnf2000EASMSTI3Port3PriorityRemoteAread-writecurrentf2000EAS Series card MSTI Port Configuration: MSTI3 Normal Port3 Configuration - Priority
1.3.6.1.4.1.4756.20.731.20.1.644Columnf2000EASMSTI3Port4PathCostRemoteAread-writecurrentf2000EAS Series card MSTI Port Configuration: MSTI3 Normal Port4 Configuration - Path Cost Valid values are in the range 0 to 200000000. Setting 0 means Auto p…
1.3.6.1.4.1.4756.20.731.20.1.645Columnf2000EASMSTI3Port4PriorityRemoteAread-writecurrentf2000EAS Series card MSTI Port Configuration: MSTI3 Normal Port4 Configuration - Priority
1.3.6.1.4.1.4756.20.731.20.1.646Columnf2000EASMSTI4AggregatedPathCostRemoteAread-writecurrentf2000EAS Series card MSTI Port Configuration: MSTI4 Aggregated Ports Configuration - Path Cost Valid values are in the range 0 to 200000000. Setting 0 means Au…
1.3.6.1.4.1.4756.20.731.20.1.647Columnf2000EASMSTI4AggregatedPriorityRemoteAread-writecurrentf2000EAS Series card MSTI Port Configuration: MSTI4 Aggregated Ports Configuration - Priority
1.3.6.1.4.1.4756.20.731.20.1.648Columnf2000EASMSTI4Port1PathCostRemoteAread-writecurrentf2000EAS Series card MSTI Port Configuration: MSTI4 Normal Port1 Configuration - Path Cost Valid values are in the range 0 to 200000000. Setting 0 means Auto p…
1.3.6.1.4.1.4756.20.731.20.1.649Columnf2000EASMSTI4Port1PriorityRemoteAread-writecurrentf2000EAS Series card MSTI Port Configuration: MSTI4 Normal Port1 Configuration - Priority
1.3.6.1.4.1.4756.20.731.20.1.650Columnf2000EASMSTI4Port2PathCostRemoteAread-writecurrentf2000EAS Series card MSTI Port Configuration: MSTI4 Normal Port2 Configuration - Path Cost Valid values are in the range 0 to 200000000. Setting 0 means Auto p…
1.3.6.1.4.1.4756.20.731.20.1.651Columnf2000EASMSTI4Port2PriorityRemoteAread-writecurrentf2000EAS Series card MSTI Port Configuration: MSTI4 Normal Port2 Configuration - Priority
1.3.6.1.4.1.4756.20.731.20.1.652Columnf2000EASMSTI4Port3PathCostRemoteAread-writecurrentf2000EAS Series card MSTI Port Configuration: MSTI1 Normal Port3 Configuration - Path Cost Valid values are in the range 0 to 200000000. Setting 0 means Auto p…
1.3.6.1.4.1.4756.20.731.20.1.653Columnf2000EASMSTI4Port3PriorityRemoteAread-writecurrentf2000EAS Series card MSTI Port Configuration: MSTI4 Normal Port3 Configuration - Priority
1.3.6.1.4.1.4756.20.731.20.1.654Columnf2000EASMSTI4Port4PathCostRemoteAread-writecurrentf2000EAS Series card MSTI Port Configuration: MSTI4 Normal Port4 Configuration - Path Cost Valid values are in the range 0 to 200000000. Setting 0 means Auto p…
1.3.6.1.4.1.4756.20.731.20.1.655Columnf2000EASMSTI4Port4PriorityRemoteAread-writecurrentf2000EAS Series card MSTI Port Configuration: MSTI4 Normal Port4 Configuration - Priority
1.3.6.1.4.1.4756.20.731.20.1.656Columnf2000EASMSTI5AggregatedPathCostRemoteAread-writecurrentf2000EAS Series card MSTI Port Configuration: MSTI5 Aggregated Ports Configuration - Path Cost Valid values are in the range 0 to 200000000. Setting 0 means Au…
1.3.6.1.4.1.4756.20.731.20.1.657Columnf2000EASMSTI5AggregatedPriorityRemoteAread-writecurrentf2000EAS Series card MSTI Port Configuration: MSTI5 Aggregated Ports Configuration - Priority
1.3.6.1.4.1.4756.20.731.20.1.658Columnf2000EASMSTI5Port1PathCostRemoteAread-writecurrentf2000EAS Series card MSTI Port Configuration: MSTI5 Normal Port1 Configuration - Path Cost Valid values are in the range 0 to 200000000. Setting 0 means Auto p…
1.3.6.1.4.1.4756.20.731.20.1.659Columnf2000EASMSTI5Port1PriorityRemoteAread-writecurrentf2000EAS Series card MSTI Port Configuration: MSTI5 Normal Port1 Configuration - Priority
1.3.6.1.4.1.4756.20.731.20.1.660Columnf2000EASMSTI5Port2PathCostRemoteAread-writecurrentf2000EAS Series card MSTI Port Configuration: MSTI5 Normal Port2 Configuration - Path Cost Valid values are in the range 0 to 200000000. Setting 0 means Auto p…
1.3.6.1.4.1.4756.20.731.20.1.661Columnf2000EASMSTI5Port2PriorityRemoteAread-writecurrentf2000EAS Series card MSTI Port Configuration: MSTI5 Normal Port2 Configuration - Priority
1.3.6.1.4.1.4756.20.731.20.1.662Columnf2000EASMSTI5Port3PathCostRemoteAread-writecurrentf2000EAS Series card MSTI Port Configuration: MSTI5 Normal Port3 Configuration - Path Cost Valid values are in the range 0 to 200000000. Setting 0 means Auto p…
1.3.6.1.4.1.4756.20.731.20.1.663Columnf2000EASMSTI5Port3PriorityRemoteAread-writecurrentf2000EAS Series card MSTI Port Configuration: MSTI5 Normal Port3 Configuration - Priority
1.3.6.1.4.1.4756.20.731.20.1.664Columnf2000EASMSTI5Port4PathCostRemoteAread-writecurrentf2000EAS Series card MSTI Port Configuration: MSTI5 Normal Port4 Configuration - Path Cost Valid values are in the range 0 to 200000000. Setting 0 means Auto p…
1.3.6.1.4.1.4756.20.731.20.1.665Columnf2000EASMSTI5Port4PriorityRemoteAread-writecurrentf2000EAS Series card MSTI Port Configuration: MSTI5 Normal Port4 Configuration - Priority
1.3.6.1.4.1.4756.20.731.20.1.666Columnf2000EASMSTI6AggregatedPathCostRemoteAread-writecurrentf2000EAS Series card MSTI Port Configuration: MSTI6 Aggregated Ports Configuration - Path Cost Valid values are in the range 0 to 200000000. Setting 0 means Au…
1.3.6.1.4.1.4756.20.731.20.1.667Columnf2000EASMSTI6AggregatedPriorityRemoteAread-writecurrentf2000EAS Series card MSTI Port Configuration: MSTI6 Aggregated Ports Configuration - Priority
1.3.6.1.4.1.4756.20.731.20.1.668Columnf2000EASMSTI6Port1PathCostRemoteAread-writecurrentf2000EAS Series card MSTI Port Configuration: MSTI6 Normal Port1 Configuration - Path Cost Valid values are in the range 0 to 200000000. Setting 0 means Auto p…
1.3.6.1.4.1.4756.20.731.20.1.669Columnf2000EASMSTI6Port1PriorityRemoteAread-writecurrentf2000EAS Series card MSTI Port Configuration: MSTI6 Normal Port1 Configuration - Priority
1.3.6.1.4.1.4756.20.731.20.1.670Columnf2000EASMSTI6Port2PathCostRemoteAread-writecurrentf2000EAS Series card MSTI Port Configuration: MSTI6 Normal Port2 Configuration - Path Cost Valid values are in the range 0 to 200000000. Setting 0 means Auto p…
1.3.6.1.4.1.4756.20.731.20.1.671Columnf2000EASMSTI6Port2PriorityRemoteAread-writecurrentf2000EAS Series card MSTI Port Configuration: MSTI6 Normal Port2 Configuration - Priority
1.3.6.1.4.1.4756.20.731.20.1.672Columnf2000EASMSTI6Port3PathCostRemoteAread-writecurrentf2000EAS Series card MSTI Port Configuration: MSTI6 Normal Port3 Configuration - Path Cost Valid values are in the range 0 to 200000000. Setting 0 means Auto p…
1.3.6.1.4.1.4756.20.731.20.1.673Columnf2000EASMSTI6Port3PriorityRemoteAread-writecurrentf2000EAS Series card MSTI Port Configuration: MSTI6 Normal Port3 Configuration - Priority
1.3.6.1.4.1.4756.20.731.20.1.674Columnf2000EASMSTI6Port4PathCostRemoteAread-writecurrentf2000EAS Series card MSTI Port Configuration: MSTI6 Normal Port4 Configuration - Path Cost Valid values are in the range 0 to 200000000. Setting 0 means Auto p…
1.3.6.1.4.1.4756.20.731.20.1.675Columnf2000EASMSTI6Port4PriorityRemoteAread-writecurrentf2000EAS Series card MSTI Port Configuration: MSTI6 Normal Port4 Configuration - Priority
1.3.6.1.4.1.4756.20.731.20.1.676Columnf2000EASMSTI7AggregatedPathCostRemoteAread-writecurrentf2000EAS Series card MSTI Port Configuration: MSTI7 Aggregated Ports Configuration - Path Cost Valid values are in the range 0 to 200000000. Setting 0 means Au…
1.3.6.1.4.1.4756.20.731.20.1.677Columnf2000EASMSTI7AggregatedPriorityRemoteAread-writecurrentf2000EAS Series card MSTI Port Configuration: MSTI7 Aggregated Ports Configuration - Priority
1.3.6.1.4.1.4756.20.731.20.1.678Columnf2000EASMSTI7Port1PathCostRemoteAread-writecurrentf2000EAS Series card MSTI Port Configuration: MSTI1 Normal Port1 Configuration - Path Cost Valid values are in the range 0 to 200000000. Setting 0 means Auto p…
1.3.6.1.4.1.4756.20.731.20.1.679Columnf2000EASMSTI7Port1PriorityRemoteAread-writecurrentf2000EAS Series card MSTI Port Configuration: MSTI1 Normal Port7 Configuration - Priority
1.3.6.1.4.1.4756.20.731.20.1.680Columnf2000EASMSTI7Port2PathCostRemoteAread-writecurrentf2000EAS Series card MSTI Port Configuration: MSTI7 Normal Port2 Configuration - Path Cost Valid values are in the range 0 to 200000000. Setting 0 means Auto p…
1.3.6.1.4.1.4756.20.731.20.1.681Columnf2000EASMSTI7Port2PriorityRemoteAread-writecurrentf2000EAS Series card MSTI Port Configuration: MSTI7 Normal Port2 Configuration - Priority
1.3.6.1.4.1.4756.20.731.20.1.682Columnf2000EASMSTI7Port3PathCostRemoteAread-writecurrentf2000EAS Series card MSTI Port Configuration: MSTI7 Normal Port3 Configuration - Path Cost Valid values are in the range 0 to 200000000. Setting 0 means Auto p…
1.3.6.1.4.1.4756.20.731.20.1.683Columnf2000EASMSTI7Port3PriorityRemoteAread-writecurrentf2000EAS Series card MSTI Port Configuration: MSTI7 Normal Port3 Configuration - Priority
1.3.6.1.4.1.4756.20.731.20.1.684Columnf2000EASMSTI7Port4PathCostRemoteAread-writecurrentf2000EAS Series card MSTI Port Configuration: MSTI7 Normal Port4 Configuration - Path Cost Valid values are in the range 0 to 200000000. Setting 0 means Auto p…
1.3.6.1.4.1.4756.20.731.20.1.685Columnf2000EASMSTI7Port4PriorityRemoteAread-writecurrentf2000EAS Series card MSTI Port Configuration: MSTI7 Normal Port4 Configuration - Priority
1.3.6.1.4.1.4756.20.731.20.1.686Columnf2000EASCISTBridgeIDRemoteAread-onlycurrentf2000EAS Series card STP Bridges status: CIST - Bridge ID
1.3.6.1.4.1.4756.20.731.20.1.687Columnf2000EASCISTRootIDRemoteAread-onlycurrentf2000EAS Series card STP Bridges status: CIST - Root ID
1.3.6.1.4.1.4756.20.731.20.1.688Columnf2000EASCISTRootPortRemoteAread-onlycurrentf2000EAS Series card STP Bridges status: CIST - Root Port
1.3.6.1.4.1.4756.20.731.20.1.689Columnf2000EASCISTRootCostRemoteAread-onlycurrentf2000EAS Series card STP Bridges status: CIST - Root Cost
1.3.6.1.4.1.4756.20.731.20.1.690Columnf2000EASCISTTopologyFlagRemoteAread-onlycurrentf2000EAS Series card STP Bridges status: CIST - Topology Flag
1.3.6.1.4.1.4756.20.731.20.1.691Columnf2000EASCISTTopologyChangeLastRemoteAread-onlycurrentf2000EAS Series card STP Bridges status: CIST - Topology Change Last
1.3.6.1.4.1.4756.20.731.20.1.692Columnf2000EASMSTI1BridgeIDRemoteAread-onlycurrentf2000EAS Series card STP Bridges status: MSTI1 - Bridge ID
1.3.6.1.4.1.4756.20.731.20.1.693Columnf2000EASMSTI1RootIDRemoteAread-onlycurrentf2000EAS Series card STP Bridges status: MSTI1 - Root ID
1.3.6.1.4.1.4756.20.731.20.1.694Columnf2000EASMSTI1RootPortRemoteAread-onlycurrentf2000EAS Series card STP Bridges status: MSTI1 - Root ID
1.3.6.1.4.1.4756.20.731.20.1.695Columnf2000EASMSTI1RootCostRemoteAread-onlycurrentf2000EAS Series card STP Bridges status: MSTI1 - Root Cost
1.3.6.1.4.1.4756.20.731.20.1.696Columnf2000EASMSTI1TopologyFlagRemoteAread-onlycurrentf2000EAS Series card STP Bridges status: MSTI1 - Topology Flag
1.3.6.1.4.1.4756.20.731.20.1.697Columnf2000EASMSTI1TopologyChangeLastRemoteAread-onlycurrentf2000EAS Series card STP Bridges status: MSTI1 - Topology Change Last
1.3.6.1.4.1.4756.20.731.20.1.698Columnf2000EASMSTI2BridgeIDRemoteAread-onlycurrentf2000EAS Series card STP Bridges status: MSTI2 - Bridge ID
1.3.6.1.4.1.4756.20.731.20.1.699Columnf2000EASMSTI2RootIDRemoteAread-onlycurrentf2000EAS Series card STP Bridges status: MSTI2 - Root ID
1.3.6.1.4.1.4756.20.731.20.1.700Columnf2000EASMSTI2RootPortRemoteAread-onlycurrentf2000EAS Series card STP Bridges status: MSTI2 - Root ID
1.3.6.1.4.1.4756.20.731.20.1.701Columnf2000EASMSTI2RootCostRemoteAread-onlycurrentf2000EAS Series card STP Bridges status: MSTI2 - Root Cost
1.3.6.1.4.1.4756.20.731.20.1.702Columnf2000EASMSTI2TopologyFlagRemoteAread-onlycurrentf2000EAS Series card STP Bridges status: MSTI2 - Topology Flag
1.3.6.1.4.1.4756.20.731.20.1.703Columnf2000EASMSTI2TopologyChangeLastRemoteAread-onlycurrentf2000EAS Series card STP Bridges status: MSTI2 - Topology Change Last
1.3.6.1.4.1.4756.20.731.20.1.704Columnf2000EASMSTI3BridgeIDRemoteAread-onlycurrentf2000EAS Series card STP Bridges status: MSTI3 - Bridge ID
1.3.6.1.4.1.4756.20.731.20.1.705Columnf2000EASMSTI3RootIDRemoteAread-onlycurrentf2000EAS Series card STP Bridges status: MSTI3 - Root ID
1.3.6.1.4.1.4756.20.731.20.1.706Columnf2000EASMSTI3RootPortRemoteAread-onlycurrentf2000EAS Series card STP Bridges status: MSTI3 - Root ID
1.3.6.1.4.1.4756.20.731.20.1.707Columnf2000EASMSTI3RootCostRemoteAread-onlycurrentf2000EAS Series card STP Bridges status: MSTI3 - Root Cost
1.3.6.1.4.1.4756.20.731.20.1.708Columnf2000EASMSTI3TopologyFlagRemoteAread-onlycurrentf2000EAS Series card STP Bridges status: MSTI3 - Topology Flag
1.3.6.1.4.1.4756.20.731.20.1.709Columnf2000EASMSTI3TopologyChangeLastRemoteAread-onlycurrentf2000EAS Series card STP Bridges status: MSTI3 - Topology Change Last
1.3.6.1.4.1.4756.20.731.20.1.710Columnf2000EASMSTI4BridgeIDRemoteAread-onlycurrentf2000EAS Series card STP Bridges status: MSTI4 - Bridge ID
1.3.6.1.4.1.4756.20.731.20.1.711Columnf2000EASMSTI4RootIDRemoteAread-onlycurrentf2000EAS Series card STP Bridges status: MSTI4 - Root ID
1.3.6.1.4.1.4756.20.731.20.1.712Columnf2000EASMSTI4RootPortRemoteAread-onlycurrentf2000EAS Series card STP Bridges status: MSTI4 - Root ID
1.3.6.1.4.1.4756.20.731.20.1.713Columnf2000EASMSTI4RootCostRemoteAread-onlycurrentf2000EAS Series card STP Bridges status: MSTI4 - Root Cost
1.3.6.1.4.1.4756.20.731.20.1.714Columnf2000EASMSTI4TopologyFlagRemoteAread-onlycurrentf2000EAS Series card STP Bridges status: MSTI4 - Topology Flag
1.3.6.1.4.1.4756.20.731.20.1.715Columnf2000EASMSTI4TopologyChangeLastRemoteAread-onlycurrentf2000EAS Series card STP Bridges status: MSTI4 - Topology Change Last
1.3.6.1.4.1.4756.20.731.20.1.716Columnf2000EASMSTI5BridgeIDRemoteAread-onlycurrentf2000EAS Series card STP Bridges status: MSTI5 - Bridge ID
1.3.6.1.4.1.4756.20.731.20.1.717Columnf2000EASMSTI5RootIDRemoteAread-onlycurrentf2000EAS Series card STP Bridges status: MSTI5 - Root ID
1.3.6.1.4.1.4756.20.731.20.1.718Columnf2000EASMSTI5RootPortRemoteAread-onlycurrentf2000EAS Series card STP Bridges status: MSTI5 - Root ID
1.3.6.1.4.1.4756.20.731.20.1.719Columnf2000EASMSTI5RootCostRemoteAread-onlycurrentf2000EAS Series card STP Bridges status: MSTI5 - Root Cost
1.3.6.1.4.1.4756.20.731.20.1.720Columnf2000EASMSTI5TopologyFlagRemoteAread-onlycurrentf2000EAS Series card STP Bridges status: MSTI5 - Topology Flag
1.3.6.1.4.1.4756.20.731.20.1.721Columnf2000EASMSTI5TopologyChangeLastRemoteAread-onlycurrentf2000EAS Series card STP Bridges status: MSTI5 - Topology Change Last
1.3.6.1.4.1.4756.20.731.20.1.722Columnf2000EASMSTI6BridgeIDRemoteAread-onlycurrentf2000EAS Series card STP Bridges status: MSTI6 - Bridge ID
1.3.6.1.4.1.4756.20.731.20.1.723Columnf2000EASMSTI6RootIDRemoteAread-onlycurrentf2000EAS Series card STP Bridges status: MSTI6 - Root ID
1.3.6.1.4.1.4756.20.731.20.1.724Columnf2000EASMSTI6RootPortRemoteAread-onlycurrentf2000EAS Series card STP Bridges status: MSTI6 - Root ID
1.3.6.1.4.1.4756.20.731.20.1.725Columnf2000EASMSTI6RootCostRemoteAread-onlycurrentf2000EAS Series card STP Bridges status: MSTI6 - Root Cost
1.3.6.1.4.1.4756.20.731.20.1.726Columnf2000EASMSTI6TopologyFlagRemoteAread-onlycurrentf2000EAS Series card STP Bridges status: MSTI6 - Topology Flag
1.3.6.1.4.1.4756.20.731.20.1.727Columnf2000EASMSTI6TopologyChangeLastRemoteAread-onlycurrentf2000EAS Series card STP Bridges status: MSTI6 - Topology Change Last
1.3.6.1.4.1.4756.20.731.20.1.728Columnf2000EASMSTI7BridgeIDRemoteAread-onlycurrentf2000EAS Series card STP Bridges status: MSTI7 - Bridge ID
1.3.6.1.4.1.4756.20.731.20.1.729Columnf2000EASMSTI7RootIDRemoteAread-onlycurrentf2000EAS Series card STP Bridges status: MSTI7 - Root ID
1.3.6.1.4.1.4756.20.731.20.1.730Columnf2000EASMSTI7RootPortRemoteAread-onlycurrentf2000EAS Series card STP Bridges status: MSTI7 - Root ID
1.3.6.1.4.1.4756.20.731.20.1.731Columnf2000EASMSTI7RootCostRemoteAread-onlycurrentf2000EAS Series card STP Bridges status: MSTI7 - Root Cost
1.3.6.1.4.1.4756.20.731.20.1.732Columnf2000EASMSTI7TopologyFlagRemoteAread-onlycurrentf2000EAS Series card STP Bridges status: MSTI7 - Topology Flag
1.3.6.1.4.1.4756.20.731.20.1.733Columnf2000EASMSTI7TopologyChangeLastRemoteAread-onlycurrentf2000EAS Series card STP Bridges status: MSTI7 - Topology Change Last
1.3.6.1.4.1.4756.20.731.20.1.734Columnf2000EASSTPPortStatusInst1PortRemoteAread-onlycurrentf2000EAS Series card STP Port status: Instance1 - Port
1.3.6.1.4.1.4756.20.731.20.1.735Columnf2000EASSTPPortStatusInst1CISTRoleRemoteAread-onlycurrentf2000EAS Series card STP Port status: Instance1 - CIST Role
1.3.6.1.4.1.4756.20.731.20.1.736Columnf2000EASSTPPortStatusInst1CISTStateRemoteAread-onlycurrentf2000EAS Series card STP Port status: Instance1 - CIST State
1.3.6.1.4.1.4756.20.731.20.1.737Columnf2000EASSTPPortStatusInst1UptimeRemoteAread-onlycurrentf2000EAS Series card STP Port status: Instance1 -Uptime
1.3.6.1.4.1.4756.20.731.20.1.738Columnf2000EASSTPPortStatusInst2PortRemoteAread-onlycurrentf2000EAS Series card STP Port status: Instance2 - Port
1.3.6.1.4.1.4756.20.731.20.1.739Columnf2000EASSTPPortStatusInst2CISTRoleRemoteAread-onlycurrentf2000EAS Series card STP Port status: Instance2 - CIST Role
1.3.6.1.4.1.4756.20.731.20.1.740Columnf2000EASSTPPortStatusInst2CISTStateRemoteAread-onlycurrentf2000EAS Series card STP Port status: Instance2 - CIST State
1.3.6.1.4.1.4756.20.731.20.1.741Columnf2000EASSTPPortStatusInst2UptimeRemoteAread-onlycurrentf2000EAS Series card STP Port status: Instance2 -Uptime
1.3.6.1.4.1.4756.20.731.20.1.742Columnf2000EASSTPPortStatusInst3PortRemoteAread-onlycurrentf2000EAS Series card STP Port status: Instance3 - Port
1.3.6.1.4.1.4756.20.731.20.1.743Columnf2000EASSTPPortStatusInst3CISTRoleRemoteAread-onlycurrentf2000EAS Series card STP Port status: Instance3 - CIST Role
1.3.6.1.4.1.4756.20.731.20.1.744Columnf2000EASSTPPortStatusInst3CISTStateRemoteAread-onlycurrentf2000EAS Series card STP Port status: Instance3 - CIST State
1.3.6.1.4.1.4756.20.731.20.1.745Columnf2000EASSTPPortStatusInst3UptimeRemoteAread-onlycurrentf2000EAS Series card STP Port status: Instance3 -Uptime
1.3.6.1.4.1.4756.20.731.20.1.746Columnf2000EASSTPPortStatusInst4PortRemoteAread-onlycurrentf2000EAS Series card STP Port status: Instance4 - Port
1.3.6.1.4.1.4756.20.731.20.1.747Columnf2000EASSTPPortStatusInst4CISTRoleRemoteAread-onlycurrentf2000EAS Series card STP Port status: Instance4 - CIST Role
1.3.6.1.4.1.4756.20.731.20.1.748Columnf2000EASSTPPortStatusInst4CISTStateRemoteAread-onlycurrentf2000EAS Series card STP Port status: Instance4 - CIST State
1.3.6.1.4.1.4756.20.731.20.1.749Columnf2000EASSTPPortStatusInst4UptimeRemoteAread-onlycurrentf2000EAS Series card STP Port status: Instance4 -Uptime
1.3.6.1.4.1.4756.20.731.20.1.750Columnf2000EASSTPStatisticsPort1TxMSTPRemoteAread-onlycurrentf2000EAS Series card STP Port Statistics: Port1 -Transmitted MSTP
1.3.6.1.4.1.4756.20.731.20.1.751Columnf2000EASSTPStatisticsPort1TxRSTPRemoteAread-onlycurrentf2000EAS Series card STP Port Statistics: Port1 -Transmitted RSTP
1.3.6.1.4.1.4756.20.731.20.1.752Columnf2000EASSTPStatisticsPort1TxSTPRemoteAread-onlycurrentf2000EAS Series card STP Port Statistics: Port1 -Transmitted RSTP
1.3.6.1.4.1.4756.20.731.20.1.753Columnf2000EASSTPStatisticsPort1TxTCNRemoteAread-onlycurrentf2000EAS Series card STP Port Statistics: Port1 -Transmitted RSTP
1.3.6.1.4.1.4756.20.731.20.1.754Columnf2000EASSTPStatisticsPort1RxMSTPRemoteAread-onlycurrentf2000EAS Series card STP Port Statistics: Port1 -Received MSTP
1.3.6.1.4.1.4756.20.731.20.1.755Columnf2000EASSTPStatisticsPort1RxRSTPRemoteAread-onlycurrentf2000EAS Series card STP Port Statistics: Port1 -Received RSTP
1.3.6.1.4.1.4756.20.731.20.1.756Columnf2000EASSTPStatisticsPort1RxSTPRemoteAread-onlycurrentf2000EAS Series card STP Port Statistics: Port1 -Received RSTP
1.3.6.1.4.1.4756.20.731.20.1.757Columnf2000EASSTPStatisticsPort1RxTCNRemoteAread-onlycurrentf2000EAS Series card STP Port Statistics: Port1 -Received RSTP
1.3.6.1.4.1.4756.20.731.20.1.758Columnf2000EASSTPStatisticsPort1DiscardUnknowRemoteAread-onlycurrentf2000EAS Series card STP Port Statistics: Port1 -Discarded Unknown
1.3.6.1.4.1.4756.20.731.20.1.759Columnf2000EASSTPStatisticsPort1DiscardIllegalRemoteAread-onlycurrentf2000EAS Series card STP Port Statistics: Port1 -Discarded Illegal
1.3.6.1.4.1.4756.20.731.20.1.760Columnf2000EASSTPStatisticsPort2TxMSTPRemoteAread-onlycurrentf2000EAS Series card STP Port Statistics: Port2 -Transmitted MSTP
1.3.6.1.4.1.4756.20.731.20.1.761Columnf2000EASSTPStatisticsPort2TxRSTPRemoteAread-onlycurrentf2000EAS Series card STP Port Statistics: Port2 -Transmitted RSTP
1.3.6.1.4.1.4756.20.731.20.1.762Columnf2000EASSTPStatisticsPort2TxSTPRemoteAread-onlycurrentf2000EAS Series card STP Port Statistics: Port2 -Transmitted RSTP
1.3.6.1.4.1.4756.20.731.20.1.763Columnf2000EASSTPStatisticsPort2TxTCNRemoteAread-onlycurrentf2000EAS Series card STP Port Statistics: Port2 -Transmitted RSTP
1.3.6.1.4.1.4756.20.731.20.1.764Columnf2000EASSTPStatisticsPort2RxMSTPRemoteAread-onlycurrentf2000EAS Series card STP Port Statistics: Port2 -Received MSTP
1.3.6.1.4.1.4756.20.731.20.1.765Columnf2000EASSTPStatisticsPort2RxRSTPRemoteAread-onlycurrentf2000EAS Series card STP Port Statistics: Port1 -Received RSTP
1.3.6.1.4.1.4756.20.731.20.1.766Columnf2000EASSTPStatisticsPort2RxSTPRemoteAread-onlycurrentf2000EAS Series card STP Port Statistics: Port2 -Received RSTP
1.3.6.1.4.1.4756.20.731.20.1.767Columnf2000EASSTPStatisticsPort2RxTCNRemoteAread-onlycurrentf2000EAS Series card STP Port Statistics: Port2 -Received RSTP
1.3.6.1.4.1.4756.20.731.20.1.768Columnf2000EASSTPStatisticsPort2DiscardUnknowRemoteAread-onlycurrentf2000EAS Series card STP Port Statistics: Port2 -Discarded Unknown
1.3.6.1.4.1.4756.20.731.20.1.769Columnf2000EASSTPStatisticsPort2DiscardIllegalRemoteAread-onlycurrentf2000EAS Series card STP Port Statistics: Port2 -Discarded Illegal
1.3.6.1.4.1.4756.20.731.20.1.770Columnf2000EASSTPStatisticsPort3TxMSTPRemoteAread-onlycurrentf2000EAS Series card STP Port Statistics: Port3 -Transmitted MSTP
1.3.6.1.4.1.4756.20.731.20.1.771Columnf2000EASSTPStatisticsPort3TxRSTPRemoteAread-onlycurrentf2000EAS Series card STP Port Statistics: Port3 -Transmitted RSTP
1.3.6.1.4.1.4756.20.731.20.1.772Columnf2000EASSTPStatisticsPort3TxSTPRemoteAread-onlycurrentf2000EAS Series card STP Port Statistics: Port3 -Transmitted RSTP
1.3.6.1.4.1.4756.20.731.20.1.773Columnf2000EASSTPStatisticsPort3TxTCNRemoteAread-onlycurrentf2000EAS Series card STP Port Statistics: Port3 -Transmitted RSTP
1.3.6.1.4.1.4756.20.731.20.1.774Columnf2000EASSTPStatisticsPort3RxMSTPRemoteAread-onlycurrentf2000EAS Series card STP Port Statistics: Port3 -Received MSTP
1.3.6.1.4.1.4756.20.731.20.1.775Columnf2000EASSTPStatisticsPort3RxRSTPRemoteAread-onlycurrentf2000EAS Series card STP Port Statistics: Port3 -Received RSTP
1.3.6.1.4.1.4756.20.731.20.1.776Columnf2000EASSTPStatisticsPort3RxSTPRemoteAread-onlycurrentf2000EAS Series card STP Port Statistics: Port3 -Received RSTP
1.3.6.1.4.1.4756.20.731.20.1.777Columnf2000EASSTPStatisticsPort3RxTCNRemoteAread-onlycurrentf2000EAS Series card STP Port Statistics: Port3 -Received RSTP
1.3.6.1.4.1.4756.20.731.20.1.778Columnf2000EASSTPStatisticsPort3DiscardUnknowRemoteAread-onlycurrentf2000EAS Series card STP Port Statistics: Port3 -Discarded Unknown
1.3.6.1.4.1.4756.20.731.20.1.779Columnf2000EASSTPStatisticsPort3DiscardIllegalRemoteAread-onlycurrentf2000EAS Series card STP Port Statistics: Port3 -Discarded Illegal
1.3.6.1.4.1.4756.20.731.20.1.780Columnf2000EASSTPStatisticsPort4TxMSTPRemoteAread-onlycurrentf2000EAS Series card STP Port Statistics: Port4 -Transmitted MSTP
1.3.6.1.4.1.4756.20.731.20.1.781Columnf2000EASSTPStatisticsPort4TxRSTPRemoteAread-onlycurrentf2000EAS Series card STP Port Statistics: Port4 -Transmitted RSTP
1.3.6.1.4.1.4756.20.731.20.1.782Columnf2000EASSTPStatisticsPort4TxSTPRemoteAread-onlycurrentf2000EAS Series card STP Port Statistics: Port4 -Transmitted RSTP
1.3.6.1.4.1.4756.20.731.20.1.783Columnf2000EASSTPStatisticsPort4TxTCNRemoteAread-onlycurrentf2000EAS Series card STP Port Statistics: Port4 -Transmitted RSTP
1.3.6.1.4.1.4756.20.731.20.1.784Columnf2000EASSTPStatisticsPort4RxMSTPRemoteAread-onlycurrentf2000EAS Series card STP Port Statistics: Port4 -Received MSTP
1.3.6.1.4.1.4756.20.731.20.1.785Columnf2000EASSTPStatisticsPort4RxRSTPRemoteAread-onlycurrentf2000EAS Series card STP Port Statistics: Port4 -Received RSTP
1.3.6.1.4.1.4756.20.731.20.1.786Columnf2000EASSTPStatisticsPort4RxSTPRemoteAread-onlycurrentf2000EAS Series card STP Port Statistics: Port4 -Received RSTP
1.3.6.1.4.1.4756.20.731.20.1.787Columnf2000EASSTPStatisticsPort4RxTCNRemoteAread-onlycurrentf2000EAS Series card STP Port Statistics: Port4 -Received RSTP
1.3.6.1.4.1.4756.20.731.20.1.788Columnf2000EASSTPStatisticsPort4DiscardUnknowRemoteAread-onlycurrentf2000EAS Series card STP Port Statistics: Port4 -Discarded Unknown
1.3.6.1.4.1.4756.20.731.20.1.789Columnf2000EASSTPStatisticsPort4DiscardIllegalRemoteAread-onlycurrentf2000EAS Series card STP Port Statistics: Port4 -Discarded Illegal
1.3.6.1.4.1.4756.20.731.20.1.790Columnf2000EASSTPStatisticsPortClearCounterRemoteAread-writecurrentf2000EAS Series card STP Port Statistics: Clear Counters 0: OFff 1: Action
1.3.6.1.4.1.4756.20.731.20.1.791Columnf2000EASAllowedAccessVLANsRemoteAread-writecurrentf2000EAS Series card Global VLAN Configuration: Allowed Access VLANs By default, only VLAN 1 is enabled. More VLANs may be created by using a list syntax where…
1.3.6.1.4.1.4756.20.731.20.1.792Columnf2000EASVlanEthertypeRemoteAread-writecurrentf2000EAS Series card Global VLAN Configuration: Ethertype for Custom S-ports The format of 'Ethernet Type' is restricted to 0x600-0xFFFF
1.3.6.1.4.1.4756.20.731.20.1.793Columnf2000EASPort1VlanModeRemoteAread-writecurrentf2000EAS Series card Port VLAN Configuration : Port1 - Mode 0: Access 1: Trunk 2: Hybrid
1.3.6.1.4.1.4756.20.731.20.1.794Columnf2000EASPort1VlanIDRemoteAread-writecurrentf2000EAS Series card Port VLAN Configuration : Port1 - VLAN ID
1.3.6.1.4.1.4756.20.731.20.1.795Columnf2000EASPort1VlanTypeRemoteAread-writecurrentf2000EAS Series card Port VLAN Configuration : Port1 - VLAN Type 0: Unaware 1: C-port 2: S-port 3: S-custom-port
1.3.6.1.4.1.4756.20.731.20.1.796Columnf2000EASPort1VlanIngressFilteringRemoteAread-writecurrentf2000EAS Series card Port VLAN Configuration : Port1 - Ingress Filtering 0: Off 1: On
1.3.6.1.4.1.4756.20.731.20.1.797Columnf2000EASPort1VlanIngressAcceptanceRemoteAread-writecurrentf2000EAS Series card Port VLAN Configuration : Port1 - Ingress Acceptance 0: Tagged and untagged 1: Tagged only 2: Untagged only
1.3.6.1.4.1.4756.20.731.20.1.798Columnf2000EASPort1VlanEgressTaggingRemoteAread-writecurrentf2000EAS Series card Port VLAN Configuration : Port1 - Egress Tagging 0: Untag port vlan 1: Tag all 2: Untag all
1.3.6.1.4.1.4756.20.731.20.1.799Columnf2000EASPort1VlanEgressTaggedSpecificallyUntagRemoteAread-writecurrentPorts in Hybrid mode may specify the tagging of frames with VID on egress, which overrules the Egress Tagging setting. Frames classified to these VLANs are tra…
1.3.6.1.4.1.4756.20.731.20.1.800Columnf2000EASPort1VlanEgressTaggedSpecificallyCtagRemoteAread-writecurrentPorts in Hybrid mode may specify the tagging of frames with VID on egress, which overrules the Egress Tagging setting. Frames classified to these VLANs are tra…
1.3.6.1.4.1.4756.20.731.20.1.801Columnf2000EASPort1VlanEgressTaggedSpecificallyStagRemoteAread-writecurrentPorts in Hybrid mode may specify the tagging of frames with VID on egress, which overrules the Egress Tagging setting. Frames classified to these VLANs are tra…
1.3.6.1.4.1.4756.20.731.20.1.802Columnf2000EASPort1VlanEgressTaggedSpecificallySCtagRemoteAread-writecurrentPorts in Hybrid mode may specify the tagging of frames with VID on egress, which overrules the Egress Tagging setting. Frames classified to these VLANs are tra…
1.3.6.1.4.1.4756.20.731.20.1.803Columnf2000EASPort1AllowedVLANSRemoteAread-writecurrentf2000EAS Series card Global VLAN Configuration: Port1 - Allowed VLANs By default, only VLAN 1 is enabled. More VLANs may be created by using a list syntax wher…
1.3.6.1.4.1.4756.20.731.20.1.804Columnf2000EASPort2VlanModeRemoteAread-writecurrentf2000EAS Series card Port VLAN Configuration : Port2 - Mode 0: Access 1: Trunk 2: Hybrid
1.3.6.1.4.1.4756.20.731.20.1.805Columnf2000EASPort2VlanIDRemoteAread-writecurrentf2000EAS Series card Port VLAN Configuration : Port2 - VLAN ID
1.3.6.1.4.1.4756.20.731.20.1.806Columnf2000EASPort2VlanTypeRemoteAread-writecurrentf2000EAS Series card Port VLAN Configuration : Port2 - VLAN Type 0: Unaware 1: C-port 2: S-port 3: S-custom-port
1.3.6.1.4.1.4756.20.731.20.1.807Columnf2000EASPort2VlanIngressFilteringRemoteAread-writecurrentf2000EAS Series card Port VLAN Configuration : Port2 - Ingress Filtering 0: Off 1: On
1.3.6.1.4.1.4756.20.731.20.1.808Columnf2000EASPort2VlanIngressAcceptanceRemoteAread-writecurrentf2000EAS Series card Port VLAN Configuration : Por2 - Ingress Acceptance 0: Tagged and untagged 1: Tagged only 2: Untagged only
1.3.6.1.4.1.4756.20.731.20.1.809Columnf2000EASPort2VlanEgressTaggingRemoteAread-writecurrentf2000EAS Series card Port VLAN Configuration : Port2 - Egress Tagging 0: Untag port vlan 1: Tag all 2: Untag all
1.3.6.1.4.1.4756.20.731.20.1.810Columnf2000EASPort2VlanEgressTaggedSpecificallyUntagRemoteAread-writecurrentPorts in Hybrid mode may specify the tagging of frames with VID on egress, which overrules the Egress Tagging setting. Frames classified to these VLANs are tra…
1.3.6.1.4.1.4756.20.731.20.1.811Columnf2000EASPort2VlanEgressTaggedSpecificallyCtagRemoteAread-writecurrentPorts in Hybrid mode may specify the tagging of frames with VID on egress, which overrules the Egress Tagging setting. Frames classified to these VLANs are tra…
1.3.6.1.4.1.4756.20.731.20.1.812Columnf2000EASPort2VlanEgressTaggedSpecificallyStagRemoteAread-writecurrentPorts in Hybrid mode may specify the tagging of frames with VID on egress, which overrules the Egress Tagging setting. Frames classified to these VLANs are tra…
1.3.6.1.4.1.4756.20.731.20.1.813Columnf2000EASPort2VlanEgressTaggedSpecificallySCtagRemoteAread-writecurrentPorts in Hybrid mode may specify the tagging of frames with VID on egress, which overrules the Egress Tagging setting. Frames classified to these VLANs are tra…
1.3.6.1.4.1.4756.20.731.20.1.814Columnf2000EASPort2AllowedVLANSRemoteAread-writecurrentf2000EAS Series card Global VLAN Configuration: Port2 - Allowed VLANs By default, only VLAN 1 is enabled. More VLANs may be created by using a list syntax wher…
1.3.6.1.4.1.4756.20.731.20.1.815Columnf2000EASPort3VlanModeRemoteAread-writecurrentf2000EAS Series card Port VLAN Configuration : Port3 - Mode 0: Access 1: Trunk 2: Hybrid
1.3.6.1.4.1.4756.20.731.20.1.816Columnf2000EASPort3VlanIDRemoteAread-writecurrentf2000EAS Series card Port VLAN Configuration : Port3 - VLAN ID
1.3.6.1.4.1.4756.20.731.20.1.817Columnf2000EASPort3VlanTypeRemoteAread-writecurrentf2000EAS Series card Port VLAN Configuration : Port3 - VLAN Type 0: Unaware 1: C-port 2: S-port 3: S-custom-port
1.3.6.1.4.1.4756.20.731.20.1.818Columnf2000EASPort3VlanIngressFilteringRemoteAread-writecurrentf2000EAS Series card Port VLAN Configuration : Port3 - Ingress Filtering 0: Off 1: On
1.3.6.1.4.1.4756.20.731.20.1.819Columnf2000EASPort3VlanIngressAcceptanceRemoteAread-writecurrentf2000EAS Series card Port VLAN Configuration : Port3 - Ingress Acceptance 0: Tagged and untagged 1: Tagged only 2: Untagged only
1.3.6.1.4.1.4756.20.731.20.1.820Columnf2000EASPort3VlanEgressTaggingRemoteAread-writecurrentf2000EAS Series card Port VLAN Configuration : Port3 - Egress Tagging 0: Untag port vlan 1: Tag all 2: Untag all
1.3.6.1.4.1.4756.20.731.20.1.821Columnf2000EASPort3VlanEgressTaggedSpecificallyUntagRemoteAread-writecurrentPorts in Hybrid mode may specify the tagging of frames with VID on egress, which overrules the Egress Tagging setting. Frames classified to these VLANs are tra…
1.3.6.1.4.1.4756.20.731.20.1.822Columnf2000EASPort3VlanEgressTaggedSpecificallyCtagRemoteAread-writecurrentPorts in Hybrid mode may specify the tagging of frames with VID on egress, which overrules the Egress Tagging setting. Frames classified to these VLANs are tra…
1.3.6.1.4.1.4756.20.731.20.1.823Columnf2000EASPort3VlanEgressTaggedSpecificallyStagRemoteAread-writecurrentPorts in Hybrid mode may specify the tagging of frames with VID on egress, which overrules the Egress Tagging setting. Frames classified to these VLANs are tra…
1.3.6.1.4.1.4756.20.731.20.1.824Columnf2000EASPort3VlanEgressTaggedSpecificallySCtagRemoteAread-writecurrentPorts in Hybrid mode may specify the tagging of frames with VID on egress, which overrules the Egress Tagging setting. Frames classified to these VLANs are tra…
1.3.6.1.4.1.4756.20.731.20.1.825Columnf2000EASPort3AllowedVLANSRemoteAread-writecurrentf2000EAS Series card Global VLAN Configuration: Port3 - Allowed VLANs By default, only VLAN 1 is enabled. More VLANs may be created by using a list syntax wher…
1.3.6.1.4.1.4756.20.731.20.1.826Columnf2000EASPort4VlanModeRemoteAread-writecurrentf2000EAS Series card Port VLAN Configuration : Port4 - Mode 0: Access 1: Trunk 2: Hybrid
1.3.6.1.4.1.4756.20.731.20.1.827Columnf2000EASPort4VlanIDRemoteAread-writecurrentf2000EAS Series card Port VLAN Configuration : Port4 - VLAN ID
1.3.6.1.4.1.4756.20.731.20.1.828Columnf2000EASPort4VlanTypeRemoteAread-writecurrentf2000EAS Series card Port VLAN Configuration : Port4 - VLAN Type 0: Unaware 1: C-port 2: S-port 3: S-custom-port
1.3.6.1.4.1.4756.20.731.20.1.829Columnf2000EASPort4VlanIngressFilteringRemoteAread-writecurrentf2000EAS Series card Port VLAN Configuration : Port4 - Ingress Filtering 0: Off 1: On
1.3.6.1.4.1.4756.20.731.20.1.830Columnf2000EASPort4VlanIngressAcceptanceRemoteAread-writecurrentf2000EAS Series card Port VLAN Configuration : Port4 - Ingress Acceptance 0: Tagged and untagged 1: Tagged only 2: Untagged only
1.3.6.1.4.1.4756.20.731.20.1.831Columnf2000EASPort4VlanEgressTaggingRemoteAread-writecurrentf2000EAS Series card Port VLAN Configuration : Port4 - Egress Tagging 0: Untag port vlan 1: Tag all 2: Untag all
1.3.6.1.4.1.4756.20.731.20.1.832Columnf2000EASPort4VlanEgressTaggedSpecificallyUntagRemoteAread-writecurrentPorts in Hybrid mode may specify the tagging of frames with VID on egress, which overrules the Egress Tagging setting. Frames classified to these VLANs are tra…
1.3.6.1.4.1.4756.20.731.20.1.833Columnf2000EASPort4VlanEgressTaggedSpecificallyCtagRemoteAread-writecurrentPorts in Hybrid mode may specify the tagging of frames with VID on egress, which overrules the Egress Tagging setting. Frames classified to these VLANs are tra…
1.3.6.1.4.1.4756.20.731.20.1.834Columnf2000EASPort4VlanEgressTaggedSpecificallyStagRemoteAread-writecurrentPorts in Hybrid mode may specify the tagging of frames with VID on egress, which overrules the Egress Tagging setting. Frames classified to these VLANs are tra…
1.3.6.1.4.1.4756.20.731.20.1.835Columnf2000EASPort4VlanEgressTaggedSpecificallySCtagRemoteAread-writecurrentPorts in Hybrid mode may specify the tagging of frames with VID on egress, which overrules the Egress Tagging setting. Frames classified to these VLANs are tra…
1.3.6.1.4.1.4756.20.731.20.1.836Columnf2000EASPort4AllowedVLANSRemoteAread-writecurrentf2000EAS Series card Global VLAN Configuration: Port4 - Allowed VLANs By default, only VLAN 1 is enabled. More VLANs may be created by using a list syntax wher…
1.3.6.1.4.1.4756.20.731.20.1.837Columnf2000EASQOSPort1IngressRemoteAread-writecurrentf2000EAS Series card QOS Port1 Ingress Enabled 0: NO 1: YES
1.3.6.1.4.1.4756.20.731.20.1.838Columnf2000EASQOSPort1IngressRateRemoteAread-writecurrentf2000EAS Series card QOS Port1 Ingress Rate
1.3.6.1.4.1.4756.20.731.20.1.839Columnf2000EASQOSPort1IngressRateUnitRemoteAread-writecurrentf2000EAS Series card QOS Port1 Ingress Rate Unit 0: Kbps 1: Mbps 2: fps 3: kfps
1.3.6.1.4.1.4756.20.731.20.1.840Columnf2000EASQOSPort1IngressBurstSizeRemoteAread-writecurrentf2000EAS Series card QOS Port1 Ingress Burst Size
1.3.6.1.4.1.4756.20.731.20.1.841Columnf2000EASQOSPort2IngressRemoteAread-writecurrentf2000EAS Series card QOS Port2 Ingress Enabled 0: NO 1: YES
1.3.6.1.4.1.4756.20.731.20.1.842Columnf2000EASQOSPort2IngressRateRemoteAread-writecurrentf2000EAS Series card QOS Port2 Ingress Rate
1.3.6.1.4.1.4756.20.731.20.1.843Columnf2000EASQOSPort2IngressRateUnitRemoteAread-writecurrentf2000EAS Series card QOS Port2 Ingress Rate Unit 0: Kbps 1: Mbps 2: fps 3: kfps
1.3.6.1.4.1.4756.20.731.20.1.844Columnf2000EASQOSPort2IngressBurstSizeRemoteAread-writecurrentf2000EAS Series card QOS Port2 Ingress Burst Size
1.3.6.1.4.1.4756.20.731.20.1.845Columnf2000EASQOSPort3IngressRemoteAread-writecurrentf2000EAS Series card QOS Port3 Ingress Enabled 0: NO 1: YES
1.3.6.1.4.1.4756.20.731.20.1.846Columnf2000EASQOSPort3IngressRateRemoteAread-writecurrentf2000EAS Series card QOS Port3 Ingress Rate
1.3.6.1.4.1.4756.20.731.20.1.847Columnf2000EASQOSPort3IngressRateUnitRemoteAread-writecurrentf2000EAS Series card QOS Port3 Ingress Rate Unit 0: Kbps 1: Mbps 2: fps 3: kfps
1.3.6.1.4.1.4756.20.731.20.1.848Columnf2000EASQOSPort3IngressBurstSizeRemoteAread-writecurrentf2000EAS Series card QOS Port3 Ingress Burst Size
1.3.6.1.4.1.4756.20.731.20.1.849Columnf2000EASQOSPort4IngressRemoteAread-writecurrentf2000EAS Series card QOS Port4 Ingress Enabled 0: NO 1: YES
1.3.6.1.4.1.4756.20.731.20.1.850Columnf2000EASQOSPort4IngressRateRemoteAread-writecurrentf2000EAS Series card QOS Port4 Ingress Rate
1.3.6.1.4.1.4756.20.731.20.1.851Columnf2000EASQOSPort4IngressRateUnitRemoteAread-writecurrentf2000EAS Series card QOS Port4 Ingress Rate Unit 0: Kbps 1: Mbps 2: fps 3: kfps
1.3.6.1.4.1.4756.20.731.20.1.852Columnf2000EASQOSPort4IngressBurstSizeRemoteAread-writecurrentf2000EAS Series card QOS Port4 Ingress Burst Size
1.3.6.1.4.1.4756.20.731.20.1.853Columnf2000EASQOSPort1EgressRemoteAread-writecurrentf2000EAS Series card QOS Port1 Egress Enabled 0: NO 1: YES
1.3.6.1.4.1.4756.20.731.20.1.854Columnf2000EASQOSPort1EgressRateRemoteAread-writecurrentf2000EAS Series card QOS Port1 Egress Rate
1.3.6.1.4.1.4756.20.731.20.1.855Columnf2000EASQOSPort1EgressRateUnitRemoteAread-writecurrentf2000EAS Series card QOS Port1 Egress Rate Unit 0: Kbps 1: Mbps
1.3.6.1.4.1.4756.20.731.20.1.856Columnf2000EASQOSPort2EgressRemoteAread-writecurrentf2000EAS Series card QOS Port2 Egress Enabled 0: NO 1: YES
1.3.6.1.4.1.4756.20.731.20.1.857Columnf2000EASQOSPort2EgressRateRemoteAread-writecurrentf2000EAS Series card QOS Port2 Egress Rate
1.3.6.1.4.1.4756.20.731.20.1.858Columnf2000EASQOSPort2EgressRateUnitRemoteAread-writecurrentf2000EAS Series card QOS Port2 Egress Rate Unit 0: Kbps 1: Mbps
1.3.6.1.4.1.4756.20.731.20.1.859Columnf2000EASQOSPort3EgressRemoteAread-writecurrentf2000EAS Series card QOS Port3 Egress Enabled 0: NO 1: YES
1.3.6.1.4.1.4756.20.731.20.1.860Columnf2000EASQOSPort3EgressRateRemoteAread-writecurrentf2000EAS Series card QOS Port3 Egress Rate
1.3.6.1.4.1.4756.20.731.20.1.861Columnf2000EASQOSPort3EgressRateUnitRemoteAread-writecurrentf2000EAS Series card QOS Port3 Egress Rate Unit 0: Kbps 1: Mbps
1.3.6.1.4.1.4756.20.731.20.1.862Columnf2000EASQOSPort4EgressRemoteAread-writecurrentf2000EAS Series card QOS Port4 Egress Enabled 0: NO 1: YES
1.3.6.1.4.1.4756.20.731.20.1.863Columnf2000EASQOSPort4EgressRateRemoteAread-writecurrentf2000EAS Series card QOS Port4 Egress Rate
1.3.6.1.4.1.4756.20.731.20.1.864Columnf2000EASQOSPort4EgressRateUnitRemoteAread-writecurrentf2000EAS Series card QOS Port4 Egress Rate Unit 0: Kbps 1: Mbps
1.3.6.1.4.1.4756.20.731.20.1.865Columnf2000EASQOSUnicastRemoteAread-writecurrentf2000EAS Series card QOS Storm Control Configuration- Unicast 0: NO 1: YES
1.3.6.1.4.1.4756.20.731.20.1.866Columnf2000EASQOSUnicastRateRemoteAread-writecurrentf2000EAS Series card QOS Storm Control Configuration- Unicast Rate
1.3.6.1.4.1.4756.20.731.20.1.867Columnf2000EASQOSUnicastRateUnitRemoteAread-onlycurrentf2000EAS Series card QOS Unicast Rate Unit 2: Fps 3: Kfps
1.3.6.1.4.1.4756.20.731.20.1.868Columnf2000EASQOSMulticastRemoteAread-writecurrentf2000EAS Series card QOS Storm Control Configuration- Multicast 0: NO 1: YES
1.3.6.1.4.1.4756.20.731.20.1.869Columnf2000EASQOSMulticastRateRemoteAread-writecurrentf2000EAS Series card QOS Storm Control Configuration- Multicast Rate
1.3.6.1.4.1.4756.20.731.20.1.870Columnf2000EASQOSMulticastRateUnitRemoteAread-onlycurrentf2000EAS Series card QOS Multicast Rate Unit 2: Fps 3: Kfps
1.3.6.1.4.1.4756.20.731.20.1.871Columnf2000EASQOSBroadcastRemoteAread-writecurrentf2000EAS Series card QOS Storm Control Configuration- Broadcast 0: NO 1: YES
1.3.6.1.4.1.4756.20.731.20.1.872Columnf2000EASQOSBroadcastRateRemoteAread-writecurrentf2000EAS Series card QOS Storm Control Configuration- Broadcast Rate
1.3.6.1.4.1.4756.20.731.20.1.873Columnf2000EASQOSBroadcastRateUnitRemoteAread-onlycurrentf2000EAS Series card QOS Broadcast Rate Unit 2: Fps 3: Kfps
1.3.6.1.4.1.4756.20.731.20.1.874Columnf2000EASPort1LLFLogicRemoteAread-writecurrentf2000EAS Series card Port1 link loss forwarding - Logic 0: AND 1: OR
1.3.6.1.4.1.4756.20.731.20.1.875Columnf2000EASPort1LLFLogicPort2RemoteAread-writecurrentf2000EAS Series card Port1 link loss forwarding - Link/Rx Loss Port2 0: NO 1: YES
1.3.6.1.4.1.4756.20.731.20.1.876Columnf2000EASPort1LLFLogicPort3RemoteAread-writecurrentf2000EAS Series card Port1 link loss forwarding - Link/Rx Loss Port3 0: NO 1: YES
1.3.6.1.4.1.4756.20.731.20.1.877Columnf2000EASPort1LLFLogicPort4RemoteAread-writecurrentf2000EAS Series card Port1 link loss forwarding - Link/Rx Loss Port4 0: NO 1: YES
1.3.6.1.4.1.4756.20.731.20.1.878Columnf2000EASPort2LLFLogicRemoteAread-writecurrentf2000EAS Series card Port2 link loss forwarding - Logic 0: AND 1: OR
1.3.6.1.4.1.4756.20.731.20.1.879Columnf2000EASPort2LLFLogicPort1RemoteAread-writecurrentf2000EAS Series card Port2 link loss forwarding - Link/Rx Loss Port1 0: NO 1: YES
1.3.6.1.4.1.4756.20.731.20.1.880Columnf2000EASPort2LLFLogicPort3RemoteAread-writecurrentf2000EAS Series card Port2 link loss forwarding - Link/Rx Loss Port3 0: NO 1: YES
1.3.6.1.4.1.4756.20.731.20.1.881Columnf2000EASPort2LLFLogicPort4RemoteAread-writecurrentf2000EAS Series card Port2 link loss forwarding - Link/Rx Loss Port4 0: NO 1: YES
1.3.6.1.4.1.4756.20.731.20.1.882Columnf2000EASPort3LLFLogicRemoteAread-writecurrentf2000EAS Series card Port3 link loss forwarding - Logic 0: AND 1: OR
1.3.6.1.4.1.4756.20.731.20.1.883Columnf2000EASPort3LLFLogicPort1RemoteAread-writecurrentf2000EAS Series card Port3 link loss forwarding - Link/Rx Loss Port1 0: NO 1: YES
1.3.6.1.4.1.4756.20.731.20.1.884Columnf2000EASPort3LLFLogicPort2RemoteAread-writecurrentf2000EAS Series card Port3 link loss forwarding - Link/Rx Loss Port2 0: NO 1: YES
1.3.6.1.4.1.4756.20.731.20.1.885Columnf2000EASPort3LLFLogicPort4RemoteAread-writecurrentf2000EAS Series card Port3 link loss forwarding - Link/Rx Loss Port4 0: NO 1: YES
1.3.6.1.4.1.4756.20.731.20.1.886Columnf2000EASPort4LLFLogicRemoteAread-writecurrentf2000EAS Series card Port4 link loss forwarding - Logic 0: AND 1: OR
1.3.6.1.4.1.4756.20.731.20.1.887Columnf2000EASPort4LLFLogicPort1RemoteAread-writecurrentf2000EAS Series card Port4 link loss forwarding - Link/Rx Loss Port1 0: NO 1: YES
1.3.6.1.4.1.4756.20.731.20.1.888Columnf2000EASPort4LLFLogicPort2RemoteAread-writecurrentf2000EAS Series card Port4 link loss forwarding - Link/Rx Loss Port2 0: NO 1: YES
1.3.6.1.4.1.4756.20.731.20.1.889Columnf2000EASPort4LLFLogicPort3RemoteAread-writecurrentf2000EAS Series card Port4 link loss forwarding - Link/Rx Loss Port3 0: NO 1: YES
1.3.6.1.4.1.4756.20.731.20.1.890Columnf2000EASAddIPRouteRemoteAread-writecurrentf2000EAS Series card IP Routes: Add a new IP Routes : Syntax: [<Interface>] [<network>] [<mask_len>] [<gateway>] [<next_hop_vlan>] Interface : 1~4
1.3.6.1.4.1.4756.20.731.20.1.891Columnf2000EASDeleteIPRouteRemoteAread-writecurrentf2000EAS Series card IP Routes num: Delete a IP Routes num: Syntax: [<Interface>] Interface: 1~4
1.3.6.1.4.1.4756.20.731.20.1.892Columnf2000EASPort1RemotePowerStsRemoteAread-onlycurrentf2000EAS Series card Port1 remote Power status 0: None 1: OK 2: Abnormal
1.3.6.1.4.1.4756.20.731.20.1.893Columnf2000EASPort2RemotePowerStsRemoteAread-onlycurrentf2000EAS Series card Port2 remote Power status 0: None 1: OK 2: Abnormal
1.3.6.1.4.1.4756.20.731.20.1.894Columnf2000EASPort3RemotePowerStsRemoteAread-onlycurrentf2000EAS Series card Port3 remote Power status 0: None 1: OK 2: Abnormal
1.3.6.1.4.1.4756.20.731.20.1.895Columnf2000EASPort4RemotePowerStsRemoteAread-onlycurrentf2000EAS Series card Port4 remote Power status 0: None 1: OK 2: Abnormal
1.3.6.1.4.1.4756.20.731.20.1.896Columnf2000EASPort1LinkAlarmRemoteAread-writecurrentf2000EAS Series card Port 1 Link alarm: 0: Disable 1: Enable
1.3.6.1.4.1.4756.20.731.20.1.897Columnf2000EASPort2LinkAlarmRemoteAread-writecurrentf2000EAS Series card Port 2 Link alarm: 0: Disable 1: Enable
1.3.6.1.4.1.4756.20.731.20.1.898Columnf2000EASPort3LinkAlarmRemoteAread-writecurrentf2000EAS Series card Port 3 Link alarm: 0: Disable 1: Enable
1.3.6.1.4.1.4756.20.731.20.1.899Columnf2000EASPort4LinkAlarmRemoteAread-writecurrentf2000EAS Series card Port 4 Link alarm: 0: Disable 1: Enable
1.3.6.1.4.1.4756.20.731.20.1.900Columnf2000EASAcceptRemoteHWResetRemoteAread-writecurrentf2000EAS Series card Accept Remote H/W Reset: 0: Disable 1: Enable
1.3.6.1.4.1.4756.20.731.20.1.901Columnf2000EASRemoteTLPTRemoteAread-writecurrentf2000EAS Series card Remote TLPT: 0: Disable 1: RemoteA 2: RemoteB
1.3.6.1.4.1.4756.20.732Nodef2000EASRemoteBCards
1.3.6.1.4.1.4756.20.732.20Tablef2000EASRemoteBTablenot-accessiblecurrentA list of RemoteB FRM220A-2000EAS series card entries.
1.3.6.1.4.1.4756.20.732.20.1Rowf2000EASRemoteBEntrynot-accessiblecurrentAn entry containing management information applicable to a particular FRM220A-2000EAS series card.
1.3.6.1.4.1.4756.20.732.20.1.1Columnf2000EASChassisIndexRemoteBread-onlycurrentA unique value for each card. It starts from 0 to 9 contiguously.
1.3.6.1.4.1.4756.20.732.20.1.2Columnf2000EASSlotIndexRemoteBread-onlycurrentA unique value for each card. It starts from 1 to 20 contiguously.
1.3.6.1.4.1.4756.20.732.20.1.3Columnf2000EASCardHWVerRemoteBread-onlycurrentf2000EAS Series card hardware version x.xxx
1.3.6.1.4.1.4756.20.732.20.1.4Columnf2000EASCardFWVerRemoteBread-onlycurrentf2000EAS Series card firmware version x.xxx
1.3.6.1.4.1.4756.20.732.20.1.5Columnf2000EASCardCPLDVerRemoteBread-onlycurrentf2000EAS Series card CPLD version x.xxx
1.3.6.1.4.1.4756.20.732.20.1.6Columnf2000EASCardFPGAVerRemoteBread-onlycurrentf2000EAS Series card FPGA version x.xxx
1.3.6.1.4.1.4756.20.732.20.1.7Columnf2000EASModelRemoteBread-onlycurrentCard Type: 0:2000EAS/4F 1:2000EAS/2F 2:2000EAS/1F
1.3.6.1.4.1.4756.20.732.20.1.8Columnf2000EASDNSServerTypeRemoteBread-writecurrentf2000EAS Series card IP Configuration: This setting controls the DNS name resolution done by the switch. The following modes are supported: 0:No DNS server No …
1.3.6.1.4.1.4756.20.732.20.1.9Columnf2000EASDNSServerSettingRemoteBread-writecurrentf2000EAS Series card IP Configuration: If iDNSServerType setting '3:Configured',this value must setting IP address format as below: Dotted Decimal Notation ref…
1.3.6.1.4.1.4756.20.732.20.1.10Columnf2000EASDNSproxyRemoteBread-writecurrentf2000EAS Series card IP Configuration: When DNS proxy is enabled, system will relay DNS requests to the currently configured DNS server, and reply as a DNS res…
1.3.6.1.4.1.4756.20.732.20.1.11Columnf2000EASAddIPV4InterfaceRemoteBread-writecurrentf2000EAS Series card IP Interfaces: Add a new IP VLAN Interface: Syntax: [<Interface>] [<vlan_list>] [<IPV4_Addr>] [<IPV4_MASK>] Interface : 1~4
1.3.6.1.4.1.4756.20.732.20.1.12Columnf2000EASDeleteInterfaceRemoteBread-writecurrentf2000EAS Series card IP Interfaces: Delete a IPv4/v6 VLAN Interface: Syntax: [<Interface>] Interface: 1~4
1.3.6.1.4.1.4756.20.732.20.1.13Columnf2000EASIPInterface1VLANRemoteBread-onlycurrentf2000EAS Series card IP Interfaces: The VLAN associated with the IP interface. Only ports in this VLAN will be able to access the IP interface. This field is o…
1.3.6.1.4.1.4756.20.732.20.1.14Columnf2000EASIPInterface1DHCPRemoteBread-writecurrentf2000EAS Series card IP Interfaces: DHCP
1.3.6.1.4.1.4756.20.732.20.1.15Columnf2000EASIPInterface1FallbackRemoteBread-writecurrentf2000EAS Series card IP Interfaces: Fallback
1.3.6.1.4.1.4756.20.732.20.1.16Columnf2000EASIPInterface1IPV4CurrentLeaseRemoteBread-onlycurrentf2000EAS Series card IP Interfaces: IPV4 Current Lease Address
1.3.6.1.4.1.4756.20.732.20.1.17Columnf2000EASIPInterface1IPV4AddressRemoteBread-onlycurrentf2000EAS Series card IP Interfaces: IPV4 Address
1.3.6.1.4.1.4756.20.732.20.1.18Columnf2000EASIPInterface1IPV4MASKLenRemoteBread-onlycurrentf2000EAS Series card IP Interfaces: IPV4 MASK Length
1.3.6.1.4.1.4756.20.732.20.1.19Columnf2000EASIPInterface2VLANRemoteBread-onlycurrentf2000EAS Series card IP Interfaces: The VLAN associated with the IP interface. Only ports in this VLAN will be able to access the IP interface. This field is o…
1.3.6.1.4.1.4756.20.732.20.1.20Columnf2000EASIPInterface2DHCPRemoteBread-writecurrentf2000EASEDD Series card IP Interfaces: DHCP
1.3.6.1.4.1.4756.20.732.20.1.21Columnf2000EASIPInterface2FallbackRemoteBread-writecurrentf2000EASEDD Series card IP Interfaces: Fallback
1.3.6.1.4.1.4756.20.732.20.1.22Columnf2000EASIPInterface2IPV4CurrentLeaseRemoteBread-onlycurrentf2000EAS Series card IP Interfaces: IPV4 Current Lease Address
1.3.6.1.4.1.4756.20.732.20.1.23Columnf2000EASIPInterface2IPV4AddressRemoteBread-onlycurrentf2000EAS Series card IP Interfaces: IPV4 Address
1.3.6.1.4.1.4756.20.732.20.1.24Columnf2000EASIPInterface2IPV4MASKLenRemoteBread-onlycurrentf2000EAS Series card IP Interfaces: IPV4 MASK Length
1.3.6.1.4.1.4756.20.732.20.1.25Columnf2000EASIPInterface3VLANRemoteBread-onlycurrentf2000EAS Series card IP Interfaces: The VLAN associated with the IP interface. Only ports in this VLAN will be able to access the IP interface. This field is o…
1.3.6.1.4.1.4756.20.732.20.1.26Columnf2000EASIPInterface3DHCPRemoteBread-writecurrentf2000EAS Series card IP Interfaces: DHCP
1.3.6.1.4.1.4756.20.732.20.1.27Columnf2000EASIPInterface3FallbackRemoteBread-writecurrentf2000EAS Series card IP Interfaces: Fallback
1.3.6.1.4.1.4756.20.732.20.1.28Columnf2000EASIPInterface3IPV4CurrentLeaseRemoteBread-onlycurrentf2000EAS Series card IP Interfaces: IPV4 Current Lease Address
1.3.6.1.4.1.4756.20.732.20.1.29Columnf2000EASIPInterface3IPV4AddressRemoteBread-onlycurrentf2000EAS Series card IP Interfaces: IPV4 Address
1.3.6.1.4.1.4756.20.732.20.1.30Columnf2000EASIPInterface3IPV4MASKLenRemoteBread-onlycurrentf2000EAS Series card IP Interfaces: IPV4 MASK Length
1.3.6.1.4.1.4756.20.732.20.1.31Columnf2000EASIPInterface4VLANRemoteBread-onlycurrentf2000EAS Series card IP Interfaces: The VLAN associated with the IP interface. Only ports in this VLAN will be able to access the IP interface. This field is o…
1.3.6.1.4.1.4756.20.732.20.1.32Columnf2000EASIPInterface4DHCPRemoteBread-writecurrentf2000EAS Series card IP Interfaces: DHCP
1.3.6.1.4.1.4756.20.732.20.1.33Columnf2000EASIPInterface4FallbackRemoteBread-writecurrentf2000EAS Series card IP Interfaces: Fallback
1.3.6.1.4.1.4756.20.732.20.1.34Columnf2000EASIPInterface4IPV4CurrentLeaseRemoteBread-onlycurrentf2000EAS Series card IP Interfaces: IPV4 Current Lease Address
1.3.6.1.4.1.4756.20.732.20.1.35Columnf2000EASIPInterface4IPV4AddressRemoteBread-onlycurrentf2000EAS Series card IP Interfaces: IPV4 Address
1.3.6.1.4.1.4756.20.732.20.1.36Columnf2000EASIPInterface4IPV4MASKLenRemoteBread-onlycurrentf2000EAS Series card IP Interfaces: IPV4 MASK Length
1.3.6.1.4.1.4756.20.732.20.1.37Columnf2000EASAddIPV6InterfaceRemoteBread-writecurrentf2000EAS Series card IP Interfaces: Add a new IPv6 VLAN Interface: Syntax: [<Interface>] [<vlan_list>] [<IPV4_Addr>] [<IPV4_MASK>] Interface : 1~4
1.3.6.1.4.1.4756.20.732.20.1.38Columnf2000EASIPInterface1IPV6DHCPRemoteBread-writecurrentf2000EAS Series card IP Interfaces: IPV6 DHCP
1.3.6.1.4.1.4756.20.732.20.1.39Columnf2000EASIPInterface1IPV6RapidCommitRemoteBread-writecurrentf2000EAS Series card IP Interfaces1: IPV6 RapidCommit
1.3.6.1.4.1.4756.20.732.20.1.40Columnf2000EASIPInterface1IPV6CurrentLeaseRemoteBread-onlycurrentf2000EAS Series card IP Interfaces: IPV6 Current lease Address
1.3.6.1.4.1.4756.20.732.20.1.41Columnf2000EASIPInterface1IPV6AddressRemoteBread-onlycurrentf2000EAS Series card IP Interfaces: IPV6 Address
1.3.6.1.4.1.4756.20.732.20.1.42Columnf2000EASIPInterface1IPV6MASKLenRemoteBread-onlycurrentf2000EAS Series card IP Interfaces: IPV6 MASK Length
1.3.6.1.4.1.4756.20.732.20.1.43Columnf2000EASIPInterface2IPV6DHCPRemoteBread-writecurrentf2000EAS Series card IP Interfaces2: IPV6 DHCP
1.3.6.1.4.1.4756.20.732.20.1.44Columnf2000EASIPInterface2IPV6RapidCommitRemoteBread-writecurrentf2000EAS Series card IP Interfaces2: IPV6 RapidCommit
1.3.6.1.4.1.4756.20.732.20.1.45Columnf2000EASIPInterface2IPV6CurrentLeaseRemoteBread-onlycurrentf2000EAS Series card IP Interfaces: IPV6 Current lease Address
1.3.6.1.4.1.4756.20.732.20.1.46Columnf2000EASIPInterface2IPV6AddressRemoteBread-onlycurrentf2000EAS Series card IP Interfaces: IPV6 Address
1.3.6.1.4.1.4756.20.732.20.1.47Columnf2000EASIPInterface2IPV6MASKLenRemoteBread-onlycurrentf2000EAS Series card IP Interfaces: IPV6 MASK Length
1.3.6.1.4.1.4756.20.732.20.1.48Columnf2000EASIPInterface3IPV6DHCPRemoteBread-writecurrentf2000EAS Series card IP Interfaces2: IPV6 DHCP
1.3.6.1.4.1.4756.20.732.20.1.49Columnf2000EASIPInterface3IPV6RapidCommitRemoteBread-writecurrentf2000EAS Series card IP Interfaces3: IPV6 RapidCommit
1.3.6.1.4.1.4756.20.732.20.1.50Columnf2000EASIPInterface3IPV6CurrentLeaseRemoteBread-onlycurrentf2000EAS Series card IP Interfaces: IPV6 Current lease Address
1.3.6.1.4.1.4756.20.732.20.1.51Columnf2000EASIPInterface3IPV6AddressRemoteBread-onlycurrentf2000EAS Series card IP Interfaces3: IPV6 Address
1.3.6.1.4.1.4756.20.732.20.1.52Columnf2000EASIPInterface3IPV6MASKLenRemoteBread-onlycurrentf2000EAS Series card IP Interfaces: IPV6 MASK Length
1.3.6.1.4.1.4756.20.732.20.1.53Columnf2000EASIPInterface4IPV6DHCPRemoteBread-writecurrentf2000EAS Series card IP Interfaces4: IPV6 DHCP
1.3.6.1.4.1.4756.20.732.20.1.54Columnf2000EASIPInterface4IPV6RapidCommitRemoteBread-writecurrentf2000EAS Series card IP Interfaces4: IPV6 RapidCommit
1.3.6.1.4.1.4756.20.732.20.1.55Columnf2000EASIPInterface4IPV6CurrentLeaseRemoteBread-onlycurrentf2000EAS Series card IP Interfaces: IPV6 Current lease Address
1.3.6.1.4.1.4756.20.732.20.1.56Columnf2000EASIPInterface4IPV6AddressRemoteBread-onlycurrentf2000EAS Series card IP Interfaces: IPV6 Address
1.3.6.1.4.1.4756.20.732.20.1.57Columnf2000EASIPInterface4IPV6MASKLenRemoteBread-onlycurrentf2000EAS Series card IP Interfaces: IPV6 MASK Length
1.3.6.1.4.1.4756.20.732.20.1.58Columnf2000EASIPRoutes1NetworkRemoteBread-onlycurrentf2000EAS Series card IP Routes: NetWork
1.3.6.1.4.1.4756.20.732.20.1.59Columnf2000EASIPRoutes1MASKLenRemoteBread-onlycurrentf2000EAS Series card IP Routes: MASK Length
1.3.6.1.4.1.4756.20.732.20.1.60Columnf2000EASIPRoutes1GetwayRemoteBread-onlycurrentf2000EAS Series card IP Routes: Getway
1.3.6.1.4.1.4756.20.732.20.1.61Columnf2000EASIPRoutes1HopVLANRemoteBread-onlycurrentf2000EAS Series card IP Routes: The VLAN associated with the IP Routes. Only ports in this VLAN will be able to access the IP Routes.
1.3.6.1.4.1.4756.20.732.20.1.62Columnf2000EASIPRoutes2NetworkRemoteBread-onlycurrentf2000EAS Series card IP Routes: NetWork
1.3.6.1.4.1.4756.20.732.20.1.63Columnf2000EASIPRoutes2MASKLenRemoteBread-onlycurrentf2000EAS Series card IP Routes: MASK Length
1.3.6.1.4.1.4756.20.732.20.1.64Columnf2000EASIPRoutes2GetwayRemoteBread-onlycurrentf2000EAS Series card IP Routes: Getway
1.3.6.1.4.1.4756.20.732.20.1.65Columnf2000EASIPRoutes2HopVLANRemoteBread-onlycurrentf2000EAS Series card IP Routes: The VLAN associated with the IP Routes. Only ports in this VLAN will be able to access the IP Routes.
1.3.6.1.4.1.4756.20.732.20.1.66Columnf2000EASIPRoutes3NetworkRemoteBread-onlycurrentf2000EAS Series card IP Routes: NetWork
1.3.6.1.4.1.4756.20.732.20.1.67Columnf2000EASIPRoutes3MASKLenRemoteBread-onlycurrentf2000EAS Series card IP Routes: MASK Length
1.3.6.1.4.1.4756.20.732.20.1.68Columnf2000EASIPRoutes3GetwayRemoteBread-onlycurrentf2000EAS Series card IP Routes: Getway
1.3.6.1.4.1.4756.20.732.20.1.69Columnf2000EASIPRoutes3HopVLANRemoteBread-onlycurrentf2000EAS Series card IP Routes: The VLAN associated with the IP Routes. Only ports in this VLAN will be able to access the IP Routes.
1.3.6.1.4.1.4756.20.732.20.1.70Columnf2000EASIPRoutes4NetworkRemoteBread-onlycurrentf2000EAS Series card IP Routes: NetWork
1.3.6.1.4.1.4756.20.732.20.1.71Columnf2000EASIPRoutes4MASKLenRemoteBread-onlycurrentf2000EAS Series card IP Routes: MASK Length
1.3.6.1.4.1.4756.20.732.20.1.72Columnf2000EASIPRoutes4GetwayRemoteBread-onlycurrentf2000EAS Series card IP Routes: Getway
1.3.6.1.4.1.4756.20.732.20.1.73Columnf2000EASIPRoutes4HopVLANRemoteBread-onlycurrentf2000EAS Series card IP Routes: The VLAN associated with the IP Routes. Only ports in this VLAN will be able to access the IP Routes.
1.3.6.1.4.1.4756.20.732.20.1.74Columnf2000EASPort1LinkstsRemoteBread-onlycurrentf2000EAS Series card Port1 link status: 0:Link down 1:Link up
1.3.6.1.4.1.4756.20.732.20.1.75Columnf2000EASPort1SpeedstsRemoteBread-onlycurrentf2000EAS Series card Port1 speed status
1.3.6.1.4.1.4756.20.732.20.1.76Columnf2000EASPort1DuplexstsRemoteBread-onlycurrentf2000EAS Series card Port1 duplex status 0: Half 1: Full
1.3.6.1.4.1.4756.20.732.20.1.77Columnf2000EASPort1RxPausestsRemoteBread-onlycurrentf2000EAS Series card Port1 rx pause status 0: No 1: Yes
1.3.6.1.4.1.4756.20.732.20.1.78Columnf2000EASPort1TxPausestsRemoteBread-onlycurrentf2000EAS Series card Port1 tx pause status 0: No 1: Yes
1.3.6.1.4.1.4756.20.732.20.1.79Columnf2000EASPort2LinkstsRemoteBread-onlycurrentf2000EAS Series card Port2 link status: 0:Link down 1:Link up
1.3.6.1.4.1.4756.20.732.20.1.80Columnf2000EASPort2SpeedstsRemoteBread-onlycurrentf2000EAS Series card Port2 speed status
1.3.6.1.4.1.4756.20.732.20.1.81Columnf2000EASPort2DuplexstsRemoteBread-onlycurrentf2000EAS Series card Port2 duplex status 0: Half 1: Full
1.3.6.1.4.1.4756.20.732.20.1.82Columnf2000EASPort2RxPausestsRemoteBread-onlycurrentf2000EAS Series card Port2 rx pause status 0: No 1: Yes
1.3.6.1.4.1.4756.20.732.20.1.83Columnf2000EASPort2TxPausestsRemoteBread-onlycurrentf2000EAS Series card Port2 tx pause status 0: No 1: Yes
1.3.6.1.4.1.4756.20.732.20.1.84Columnf2000EASPort3LinkstsRemoteBread-onlycurrentf2000EAS Series card Port3 link status: 0:Link down 1:Link up
1.3.6.1.4.1.4756.20.732.20.1.85Columnf2000EASPort3SpeedstsRemoteBread-onlycurrentf2000EAS Series card Port3 speed status
1.3.6.1.4.1.4756.20.732.20.1.86Columnf2000EASPort3DuplexstsRemoteBread-onlycurrentf2000EAS Series card Port3 duplex status 0: Half 1: Full
1.3.6.1.4.1.4756.20.732.20.1.87Columnf2000EASPort3RxPausestsRemoteBread-onlycurrentf2000EAS Series card Port3 rx pause status 0: No 1: Yes
1.3.6.1.4.1.4756.20.732.20.1.88Columnf2000EASPort3TxPausestsRemoteBread-onlycurrentf2000EAS Series card Port3 tx pause status 0: No 1: Yes
1.3.6.1.4.1.4756.20.732.20.1.89Columnf2000EASPort4LinkstsRemoteBread-onlycurrentf2000EAS Series card Port4 link status: 0:Link down 1:Link up
1.3.6.1.4.1.4756.20.732.20.1.90Columnf2000EASPort4SpeedstsRemoteBread-onlycurrentf2000EAS Series card Port4 speed status
1.3.6.1.4.1.4756.20.732.20.1.91Columnf2000EASPort4DuplexstsRemoteBread-onlycurrentf2000EAS Series card Port4 duplex status 0: Half 1: Full
1.3.6.1.4.1.4756.20.732.20.1.92Columnf2000EASPort4RxPausestsRemoteBread-onlycurrentf2000EAS Series card Port4 rx pause status 0: No 1: Yes
1.3.6.1.4.1.4756.20.732.20.1.93Columnf2000EASPort4TxPausestsRemoteBread-onlycurrentf2000EAS Series card Port4 tx pause status 0: No 1: Yes
1.3.6.1.4.1.4756.20.732.20.1.94Columnf2000EASPort1SpeedConfRemoteBread-writecurrentf2000EAS Series card Port1 speed config 0: disable 1: auto 2: 100M FDX 3: 1G FDX
1.3.6.1.4.1.4756.20.732.20.1.95Columnf2000EASPort1flowConrolRemoteBread-writecurrentf2000EAS Series card Port1 flow control config 0: no 1: yes
1.3.6.1.4.1.4756.20.732.20.1.96Columnf2000EASPort1MaxFrameRemoteBread-writecurrentf2000EAS Series card Port1 max frame config
1.3.6.1.4.1.4756.20.732.20.1.97Columnf2000EASPort1ALSRemoteBread-writecurrentf2000EAS Series card Port1 auto laser shutdown: 0: Disable 1: Enable
1.3.6.1.4.1.4756.20.732.20.1.98Columnf2000EASPort1FrameLengthCheckRemoteBread-writecurrentf2000EAS Series card Port1 Frame Length Check config 0: no 1: yes
1.3.6.1.4.1.4756.20.732.20.1.99Columnf2000EASPort2SpeedConfRemoteBread-writecurrentf2000EAS Series card Port2 speed config 0: disable 1: auto 2: 100M FDX 3: 1G FDX
1.3.6.1.4.1.4756.20.732.20.1.100Columnf2000EASPort2flowConrolRemoteBread-writecurrentf2000EAS Series card Port2 flow control config 0: no 1: yes
1.3.6.1.4.1.4756.20.732.20.1.101Columnf2000EASPort2MaxFrameRemoteBread-writecurrentf2000EAS Series card Port2 max frame config
1.3.6.1.4.1.4756.20.732.20.1.102Columnf2000EASPort2ALSRemoteBread-writecurrentf2000EAS Series card Port2 auto laser shutdown: 0: Disable 1: Enable
1.3.6.1.4.1.4756.20.732.20.1.103Columnf2000EASPort2FrameLengthCheckRemoteBread-writecurrentf2000EAS Series card Port2 Frame Length Check config 0: no 1: yes
1.3.6.1.4.1.4756.20.732.20.1.104Columnf2000EASPort3SpeedConfRemoteBread-writecurrentf2000EAS Series card Port3 speed config 0: disable 1: auto 2: 10M HDX 3: 10M FDX 4: 100M HDX 5: 100M FDX 6: 1G FDX
1.3.6.1.4.1.4756.20.732.20.1.105Columnf2000EASPort3flowConrolRemoteBread-writecurrentf2000EAS Series card Port3 flow control config 0: no 1: yes
1.3.6.1.4.1.4756.20.732.20.1.106Columnf2000EASPort3MaxFrameRemoteBread-writecurrentf2000EAS Series card Port3 max frame config
1.3.6.1.4.1.4756.20.732.20.1.107Columnf2000EASPort3CollisionModeRemoteBread-writecurrentf2000EAS Series card Port3 collision mode config. 0: Discard 1: Restart
1.3.6.1.4.1.4756.20.732.20.1.108Columnf2000EASPort3ALSRemoteBread-writecurrentf2000EAS Series card Port3 auto laser shutdown 0: Disable 1: Enable
1.3.6.1.4.1.4756.20.732.20.1.109Columnf2000EASPort3FrameLengthCheckRemoteBread-writecurrentf2000EAS Series card Port3 Frame Length Check config 0: no 1: yes
1.3.6.1.4.1.4756.20.732.20.1.110Columnf2000EASPort4SpeedConfRemoteBread-writecurrentf2000EAS Series card Port4 speed config 0: disable 1: auto 2: 10M HDX 3: 10M FDX 4: 100M HDX 5: 100M FDX 6: 1G FDX
1.3.6.1.4.1.4756.20.732.20.1.111Columnf2000EASPort4flowConrolRemoteBread-writecurrentf2000EAS Series card Port4 flow control config 0: no 1: yes
1.3.6.1.4.1.4756.20.732.20.1.112Columnf2000EASPort4MaxFrameRemoteBread-writecurrentf2000EAS Series card Port4 max frame config
1.3.6.1.4.1.4756.20.732.20.1.113Columnf2000EASPort4CollisionModeRemoteBread-writecurrentf2000EAS Series card Port4 collision mode config 0: Discard 1: Restart
1.3.6.1.4.1.4756.20.732.20.1.114Columnf2000EASPort4ALSRemoteBread-writecurrentf2000EAS Series card Port4 auto laser shutdown 0: Disable 1: Enable
1.3.6.1.4.1.4756.20.732.20.1.115Columnf2000EASPort4FrameLengthCheckRemoteBread-writecurrentf2000EAS Series card Port4 Frame Length Check config 0: no 1: yes
1.3.6.1.4.1.4756.20.732.20.1.116Columnf2000EASPort1AdvDuplexHdxRemoteBread-writecurrentf2000EAS Series card Port1 Adv Dpulex Hdx 0: OFF 1: ON
1.3.6.1.4.1.4756.20.732.20.1.117Columnf2000EASPort1AdvDuplexFdxRemoteBread-writecurrentf2000EAS Series card Port1 Adv Dpulex Fdx 0: OFF 1: ON
1.3.6.1.4.1.4756.20.732.20.1.118Columnf2000EASPort1AdvSpeed10MRemoteBread-writecurrentf2000EAS Series card Port1 Adv Speed 10M 0: OFF 1: ON
1.3.6.1.4.1.4756.20.732.20.1.119Columnf2000EASPort1AdvSpeed100MRemoteBread-writecurrentf2000EAS Series card Port1 Adv Speed 100M 0: OFF 1: ON
1.3.6.1.4.1.4756.20.732.20.1.120Columnf2000EASPort1AdvSpeed1GRemoteBread-writecurrentf2000EAS Series card Port1 Adv Speed 1G 0: OFF 1: ON
1.3.6.1.4.1.4756.20.732.20.1.121Columnf2000EASPort2AdvDuplexHdxRemoteBread-writecurrentf2000EAS Series card Port2 Adv Dpulex Hdx 0: OFF 1: ON
1.3.6.1.4.1.4756.20.732.20.1.122Columnf2000EASPort2AdvDuplexFdxRemoteBread-writecurrentf2000EAS Series card Port2 Adv Dpulex Fdx 0: OFF 1: ON
1.3.6.1.4.1.4756.20.732.20.1.123Columnf2000EASPort2AdvSpeed10MRemoteBread-writecurrentf2000EAS Series card Port2 Adv Speed 10M 0: OFF 1: ON
1.3.6.1.4.1.4756.20.732.20.1.124Columnf2000EASPort2AdvSpeed100MRemoteBread-writecurrentf2000EAS Series card Port2 Adv Speed 100M 0: OFF 1: ON
1.3.6.1.4.1.4756.20.732.20.1.125Columnf2000EASPort2AdvSpeed1GRemoteBread-writecurrentf2000EAS Series card Port2 Adv Speed 1G 0: OFF 1: ON
1.3.6.1.4.1.4756.20.732.20.1.126Columnf2000EASPort3AdvDuplexHdxRemoteBread-writecurrentf2000EAS Series card Port3 Adv Dpulex Hdx 0: OFF 1: ON
1.3.6.1.4.1.4756.20.732.20.1.127Columnf2000EASPort3AdvDuplexFdxRemoteBread-writecurrentf2000EAS Series card Port3 Adv Dpulex Fdx 0: OFF 1: ON
1.3.6.1.4.1.4756.20.732.20.1.128Columnf2000EASPort3AdvSpeed10MRemoteBread-writecurrentf2000EAS Series card Port3 Adv Speed 10M 0: OFF 1: ON
1.3.6.1.4.1.4756.20.732.20.1.129Columnf2000EASPort3AdvSpeed100MRemoteBread-writecurrentf2000EAS Series card Port3 Adv Speed 100M 0: OFF 1: ON
1.3.6.1.4.1.4756.20.732.20.1.130Columnf2000EASPort3AdvSpeed1GRemoteBread-writecurrentf2000EAS Series card Port3 Adv Speed 1G 0: OFF 1: ON
1.3.6.1.4.1.4756.20.732.20.1.131Columnf2000EASPort4AdvDuplexHdxRemoteBread-writecurrentf2000EAS Series card Port4 Adv Dpulex Hdx 0: OFF 1: ON
1.3.6.1.4.1.4756.20.732.20.1.132Columnf2000EASPort4AdvDuplexFdxRemoteBread-writecurrentf2000EAS Series card Port4 Adv Dpulex Fdx 0: OFF 1: ON
1.3.6.1.4.1.4756.20.732.20.1.133Columnf2000EASPort4AdvSpeed10MRemoteBread-writecurrentf2000EAS Series card Port4 Adv Speed 10M 0: OFF 1: ON
1.3.6.1.4.1.4756.20.732.20.1.134Columnf2000EASPort4AdvSpeed100MRemoteBread-writecurrentf2000EAS Series card Port4 Adv Speed 100M 0: OFF 1: ON
1.3.6.1.4.1.4756.20.732.20.1.135Columnf2000EASPort4AdvSpeed1GRemoteBread-writecurrentf2000EAS Series card Port4 Adv Speed 1G 0: OFF 1: ON
1.3.6.1.4.1.4756.20.732.20.1.136Columnf2000EASPortResetRemoteBread-writecurrentf2000EAS Series card port reset 0: OFF 1: Action
1.3.6.1.4.1.4756.20.732.20.1.137Columnf2000EASSetDefaultRemoteBread-writecurrentf2000EAS Series card set to default config 0: OFF 1: Action
1.3.6.1.4.1.4756.20.732.20.1.138Columnf2000EASPort1PacketsRxRemoteBread-onlycurrentf2000EAS Series card port1 traffic overview:: Packets Rx
1.3.6.1.4.1.4756.20.732.20.1.139Columnf2000EASPort1PacketsTxRemoteBread-onlycurrentf2000EAS Series card port1 traffic overview:: Packets Tx
1.3.6.1.4.1.4756.20.732.20.1.140Columnf2000EASPort1BytesRxRemoteBread-onlycurrentf2000EAS Series card port1 traffic overview:: Bytes Rx
1.3.6.1.4.1.4756.20.732.20.1.141Columnf2000EASPort1BytesTxRemoteBread-onlycurrentf2000EAS Series card port1 traffic overview:: Bytes Tx
1.3.6.1.4.1.4756.20.732.20.1.142Columnf2000EASPort1ErrorsRxRemoteBread-onlycurrentf2000EAS Series card port1 traffic overview:: Errors Rx
1.3.6.1.4.1.4756.20.732.20.1.143Columnf2000EASPort1ErrorsTxRemoteBread-onlycurrentf2000EAS Series card port1 traffic overview:: Errors Tx
1.3.6.1.4.1.4756.20.732.20.1.144Columnf2000EASPort1DropsRxRemoteBread-onlycurrentf2000EAS Series card port1 traffic overview:: Drops Rx
1.3.6.1.4.1.4756.20.732.20.1.145Columnf2000EASPort1DropsTxRemoteBread-onlycurrentf2000EAS Series card port1 traffic overview:: Drops Tx
1.3.6.1.4.1.4756.20.732.20.1.146Columnf2000EASPort1FilteredRxRemoteBread-onlycurrentf2000EAS Series card port1 traffic overview:: Filtered Rx
1.3.6.1.4.1.4756.20.732.20.1.147Columnf2000EASPort2PacketsRxRemoteBread-onlycurrentf2000EAS Series card port2 traffic overview:: Packets Rx
1.3.6.1.4.1.4756.20.732.20.1.148Columnf2000EASPort2PacketsTxRemoteBread-onlycurrentf2000EAS Series card port2 traffic overview:: Packets Tx
1.3.6.1.4.1.4756.20.732.20.1.149Columnf2000EASPort2BytesRxRemoteBread-onlycurrentf2000EAS Series card port2 traffic overview:: Bytes Rx
1.3.6.1.4.1.4756.20.732.20.1.150Columnf2000EASPort2BytesTxRemoteBread-onlycurrentf2000EAS Series card port2 traffic overview:: Bytes Tx
1.3.6.1.4.1.4756.20.732.20.1.151Columnf2000EASPort2ErrorsRxRemoteBread-onlycurrentf2000EAS Series card port2 traffic overview:: Errors Rx
1.3.6.1.4.1.4756.20.732.20.1.152Columnf2000EASPort2ErrorsTxRemoteBread-onlycurrentf2000EAS Series card port2 traffic overview:: Errors Tx
1.3.6.1.4.1.4756.20.732.20.1.153Columnf2000EASPort2DropsRxRemoteBread-onlycurrentf2000EAS Series card port2 traffic overview:: Drops Rx
1.3.6.1.4.1.4756.20.732.20.1.154Columnf2000EASPort2DropsTxRemoteBread-onlycurrentf2000EAS Series card port2 traffic overview:: Drops Tx
1.3.6.1.4.1.4756.20.732.20.1.155Columnf2000EASPort2FilteredRxRemoteBread-onlycurrentf2000EAS Series card port2 traffic overview:: Filtered Rx
1.3.6.1.4.1.4756.20.732.20.1.156Columnf2000EASPort3PacketsRxRemoteBread-onlycurrentf2000EAS Series card port3 traffic overview:: Packets Rx
1.3.6.1.4.1.4756.20.732.20.1.157Columnf2000EASPort3PacketsTxRemoteBread-onlycurrentf2000EAS Series card port3 traffic overview:: Packets Tx
1.3.6.1.4.1.4756.20.732.20.1.158Columnf2000EASPort3BytesRxRemoteBread-onlycurrentf2000EAS Series card port3 traffic overview:: Bytes Rx
1.3.6.1.4.1.4756.20.732.20.1.159Columnf2000EASPort3BytesTxRemoteBread-onlycurrentf2000EAS Series card port3 traffic overview:: Bytes Tx
1.3.6.1.4.1.4756.20.732.20.1.160Columnf2000EASPort3ErrorsRxRemoteBread-onlycurrentf2000EAS Series card port3 traffic overview:: Errors Rx
1.3.6.1.4.1.4756.20.732.20.1.161Columnf2000EASPort3ErrorsTxRemoteBread-onlycurrentf2000EAS Series card port3 traffic overview:: Errors Tx
1.3.6.1.4.1.4756.20.732.20.1.162Columnf2000EASPort3DropsRxRemoteBread-onlycurrentf2000EAS Series card port3 traffic overview:: Drops Rx
1.3.6.1.4.1.4756.20.732.20.1.163Columnf2000EASPort3DropsTxRemoteBread-onlycurrentf2000EAS Series card port3 traffic overview:: Drops Tx
1.3.6.1.4.1.4756.20.732.20.1.164Columnf2000EASPort3FilteredRxRemoteBread-onlycurrentf2000EAS Series card port3 traffic overview:: Filtered Rx
1.3.6.1.4.1.4756.20.732.20.1.165Columnf2000EASPort4PacketsRxRemoteBread-onlycurrentf2000EAS Series card port4 traffic overview:: Packets Rx
1.3.6.1.4.1.4756.20.732.20.1.166Columnf2000EASPort4PacketsTxRemoteBread-onlycurrentf2000EAS Series card port4 traffic overview:: Packets Tx
1.3.6.1.4.1.4756.20.732.20.1.167Columnf2000EASPort4BytesRxRemoteBread-onlycurrentf2000EAS Series card port4 traffic overview:: Bytes Rx
1.3.6.1.4.1.4756.20.732.20.1.168Columnf2000EASPort4BytesTxRemoteBread-onlycurrentf2000EAS Series card port4 traffic overview:: Bytes Tx
1.3.6.1.4.1.4756.20.732.20.1.169Columnf2000EASPort4ErrorsRxRemoteBread-onlycurrentf2000EAS Series card port4 traffic overview:: Errors Rx
1.3.6.1.4.1.4756.20.732.20.1.170Columnf2000EASPort4ErrorsTxRemoteBread-onlycurrentf2000EAS Series card port4 traffic overview:: Errors Tx
1.3.6.1.4.1.4756.20.732.20.1.171Columnf2000EASPort4DropsRxRemoteBread-onlycurrentf2000EAS Series card port4 traffic overview:: Drops Rx
1.3.6.1.4.1.4756.20.732.20.1.172Columnf2000EASPort4DropsTxRemoteBread-onlycurrentf2000EAS Series card port4 traffic overview:: Drops Tx
1.3.6.1.4.1.4756.20.732.20.1.173Columnf2000EASPort4FilteredRxRemoteBread-onlycurrentf2000EAS Series card port4 traffic overview:: Filtered Rx
1.3.6.1.4.1.4756.20.732.20.1.174Columnf2000EASDeviceActiveRemoteBread-onlycurrentf2000EAS Series card device active 0: Disable 1: Enable
1.3.6.1.4.1.4756.20.732.20.1.175Columnf2000EASFx1DDRemoteBread-onlycurrentf2000EAS Series card fiber1 port Digital Diagnostic function: 0:No 1:Yes
1.3.6.1.4.1.4756.20.732.20.1.176Columnf2000EASFx1DDVendorRemoteBread-onlycurrentf2000EAS Series card fiber1 port D/D information: Vendor name
1.3.6.1.4.1.4756.20.732.20.1.177Columnf2000EASFx1DDPartNoRemoteBread-onlycurrentf2000EAS Series card fiber1 port D/D information: Vendor part number
1.3.6.1.4.1.4756.20.732.20.1.178Columnf2000EASFx1DDFiberTypeRemoteBread-onlycurrentf2000EAS Series card fiber1 port D/D information: Fiber Type
1.3.6.1.4.1.4756.20.732.20.1.179Columnf2000EASFx1DDWaveLenRemoteBread-onlycurrentf2000EAS Series card fiber1 port D/D information: Wave length
1.3.6.1.4.1.4756.20.732.20.1.180Columnf2000EASFx1DDWaveLen2RemoteBread-onlycurrentf2000EAS Series card fiber1 port D/D information: Wave length 2
1.3.6.1.4.1.4756.20.732.20.1.181Columnf2000EASFx1DDLinkLenRemoteBread-onlycurrentf2000EAS Series card fiber1 port D/D information: Link length
1.3.6.1.4.1.4756.20.732.20.1.182Columnf2000EASFx1DDLenUnitRemoteBread-onlycurrentf2000EAS Series card fiber1 port D/D information: Length Unit
1.3.6.1.4.1.4756.20.732.20.1.183Columnf2000EASFx1DDStatusRemoteBread-onlycurrentf2000EAS Series card fiber1 port D/D information: Status Support
1.3.6.1.4.1.4756.20.732.20.1.184Columnf2000EASFx1DDRxSensRemoteBread-onlycurrentf2000EAS Series card fiber1 port D/D information: Rx Sensitivity
1.3.6.1.4.1.4756.20.732.20.1.185Columnf2000EASFx1DDTxPWRRemoteBread-onlycurrentf2000EAS Series card fiber1 port D/D information: Tx power
1.3.6.1.4.1.4756.20.732.20.1.186Columnf2000EASFx1DDRxPWRRemoteBread-onlycurrentf2000EAS Series card fiber1 port D/D information: Rx power
1.3.6.1.4.1.4756.20.732.20.1.187Columnf2000EASFx1DDTempRemoteBread-onlycurrentf2000EAS Series card fiber1 port D/D information: Temperature in degree C
1.3.6.1.4.1.4756.20.732.20.1.188Columnf2000EASFx1DDPWRMarginRemoteBread-onlycurrentf2000EAS Series card fiber1 port D/D information: Power margin
1.3.6.1.4.1.4756.20.732.20.1.189Columnf2000EASFx1DDPWRLossRemoteBread-onlycurrentf2000EAS Series card fiber1 port D/D information: Power loss
1.3.6.1.4.1.4756.20.732.20.1.190Columnf2000EASFx2DDRemoteBread-onlycurrentf2000EAS Series card fiber2 Digital Diagnostic function: 0:NO 1:Yes
1.3.6.1.4.1.4756.20.732.20.1.191Columnf2000EASFx2DDVendorRemoteBread-onlycurrentf2000EAS Series card fiber2 D/D information: Vendor name
1.3.6.1.4.1.4756.20.732.20.1.192Columnf2000EASFx2DDPartNoRemoteBread-onlycurrentf2000EAS Series card fiber2 D/D information: Vendor part number
1.3.6.1.4.1.4756.20.732.20.1.193Columnf2000EASFx2DDFiberTypeRemoteBread-onlycurrentf2000EAS Series card fiber2 D/D information: Fiber Type
1.3.6.1.4.1.4756.20.732.20.1.194Columnf2000EASFx2DDWaveLenRemoteBread-onlycurrentf2000EAS Series card fiber2 D/D information: Wave length 1
1.3.6.1.4.1.4756.20.732.20.1.195Columnf2000EASFx2DDWaveLen2RemoteBread-onlycurrentf2000EAS Series card fiber2 D/D information: Wave length 2
1.3.6.1.4.1.4756.20.732.20.1.196Columnf2000EASFx2DDLinkLenRemoteBread-onlycurrentf2000EAS Series card fiber2 D/D information: Link length
1.3.6.1.4.1.4756.20.732.20.1.197Columnf2000EASFx2DDLenUnitRemoteBread-onlycurrentf2000EAS Series card fiber2 D/D information: Length Unit
1.3.6.1.4.1.4756.20.732.20.1.198Columnf2000EASFx2DDStatusRemoteBread-onlycurrentf2000EAS Series card fiber2 D/D information: Status Support
1.3.6.1.4.1.4756.20.732.20.1.199Columnf2000EASFx2DDRxSensRemoteBread-onlycurrentf2000EAS Series card fiber2 D/D information: Rx Sensitivity
1.3.6.1.4.1.4756.20.732.20.1.200Columnf2000EASFx2DDTxPWRRemoteBread-onlycurrentf2000EAS Series card fiber2 D/D information: Tx power
1.3.6.1.4.1.4756.20.732.20.1.201Columnf2000EASFx2DDRxPWRRemoteBread-onlycurrentf2000EAS Series card fiber2 D/D information: Rx power
1.3.6.1.4.1.4756.20.732.20.1.202Columnf2000EASFx2DDTempRemoteBread-onlycurrentf2000EAS Series card fiber2 D/D information: Temperature in degree C
1.3.6.1.4.1.4756.20.732.20.1.203Columnf2000EASFx2DDPWRMarginRemoteBread-onlycurrentf2000EAS Series card fiber2 D/D information: Power margin
1.3.6.1.4.1.4756.20.732.20.1.204Columnf2000EASFx2DDPWRLossRemoteBread-onlycurrentf2000EAS Series card fiber2 D/D information: Power loss
1.3.6.1.4.1.4756.20.732.20.1.205Columnf2000EASFx3DDRemoteBread-onlycurrentf2000EAS Series card fiber3 Digital Diagnostic function: 0:NO 1:Yes
1.3.6.1.4.1.4756.20.732.20.1.206Columnf2000EASFx3DDVendorRemoteBread-onlycurrentf2000EAS Series card fiber3 D/D information: Vendor name
1.3.6.1.4.1.4756.20.732.20.1.207Columnf2000EASFx3DDPartNoRemoteBread-onlycurrentf2000EAS Series card fiber32 D/D information: Vendor part number
1.3.6.1.4.1.4756.20.732.20.1.208Columnf2000EASFx3DDFiberTypeRemoteBread-onlycurrentf2000EAS Series card fiber3 D/D information: Fiber Type
1.3.6.1.4.1.4756.20.732.20.1.209Columnf2000EASFx3DDWaveLenRemoteBread-onlycurrentf2000EAS Series card fiber3 D/D information: Wave length 1
1.3.6.1.4.1.4756.20.732.20.1.210Columnf2000EASFx3DDWaveLen2RemoteBread-onlycurrentf2000EAS Series card fiber3 D/D information: Wave length 2
1.3.6.1.4.1.4756.20.732.20.1.211Columnf2000EASFx3DDLinkLenRemoteBread-onlycurrentf2000EAS Series card fiber3 D/D information: Link length
1.3.6.1.4.1.4756.20.732.20.1.212Columnf2000EASFx3DDLenUnitRemoteBread-onlycurrentf2000EAS Series card fiber3 D/D information: Length Unit
1.3.6.1.4.1.4756.20.732.20.1.213Columnf2000EASFx3DDStatusRemoteBread-onlycurrentf2000EAS Series card fiber3 D/D information: Status Support
1.3.6.1.4.1.4756.20.732.20.1.214Columnf2000EASFx3DDRxSensRemoteBread-onlycurrentf2000EAS Series card fiber3 D/D information: Rx Sensitivity
1.3.6.1.4.1.4756.20.732.20.1.215Columnf2000EASFx3DDTxPWRRemoteBread-onlycurrentf2000EAS Series card fiber3 D/D information: Tx power
1.3.6.1.4.1.4756.20.732.20.1.216Columnf2000EASFx3DDRxPWRRemoteBread-onlycurrentf2000EAS Series card fiber3 D/D information: Rx power
1.3.6.1.4.1.4756.20.732.20.1.217Columnf2000EASFx3DDTempRemoteBread-onlycurrentf2000EAS Series card fiber3 D/D information: Temperature in degree C
1.3.6.1.4.1.4756.20.732.20.1.218Columnf2000EASFx3DDPWRMarginRemoteBread-onlycurrentf2000EAS Series card fiber3 D/D information: Power margin
1.3.6.1.4.1.4756.20.732.20.1.219Columnf2000EASFx3DDPWRLossRemoteBread-onlycurrentf2000EAS Series card fiber3 D/D information: Power loss
1.3.6.1.4.1.4756.20.732.20.1.220Columnf2000EASFx4DDRemoteBread-onlycurrentf2000EAS Series card fiber4 Digital Diagnostic function: 0:NO 1:Yes
1.3.6.1.4.1.4756.20.732.20.1.221Columnf2000EASFx4DDVendorRemoteBread-onlycurrentf2000EAS Series card fiber4 D/D information: Vendor name
1.3.6.1.4.1.4756.20.732.20.1.222Columnf2000EASFx4DDPartNoRemoteBread-onlycurrentf2000EAS Series card fiber4 D/D information: Vendor part number
1.3.6.1.4.1.4756.20.732.20.1.223Columnf2000EASFx4DDFiberTypeRemoteBread-onlycurrentf2000EAS Series card fiber4 D/D information: Fiber Type
1.3.6.1.4.1.4756.20.732.20.1.224Columnf2000EASFx4DDWaveLenRemoteBread-onlycurrentf2000EAS Series card fiber4 D/D information: Wave length 1
1.3.6.1.4.1.4756.20.732.20.1.225Columnf2000EASFx4DDWaveLen2RemoteBread-onlycurrentf2000EAS Series card fiber4 D/D information: Wave length 2
1.3.6.1.4.1.4756.20.732.20.1.226Columnf2000EASFx4DDLinkLenRemoteBread-onlycurrentf2000EAS Series card fiber4 D/D information: Link length
1.3.6.1.4.1.4756.20.732.20.1.227Columnf2000EASFx4DDLenUnitRemoteBread-onlycurrentf2000EAS Series card fiber4 D/D information: Length Unit
1.3.6.1.4.1.4756.20.732.20.1.228Columnf2000EASFx4DDStatusRemoteBread-onlycurrentf2000EAS Series card fiber4 D/D information: Status Support
1.3.6.1.4.1.4756.20.732.20.1.229Columnf2000EASFx4DDRxSensRemoteBread-onlycurrentf2000EAS Series card fiber4 D/D information: Rx Sensitivity
1.3.6.1.4.1.4756.20.732.20.1.230Columnf2000EASFx4DDTxPWRRemoteBread-onlycurrentf2000EAS Series card fiber4 D/D information: Tx power
1.3.6.1.4.1.4756.20.732.20.1.231Columnf2000EASFx4DDRxPWRRemoteBread-onlycurrentf2000EAS Series card fiber4 D/D information: Rx power
1.3.6.1.4.1.4756.20.732.20.1.232Columnf2000EASFx4DDTempRemoteBread-onlycurrentf2000EAS Series card fiber4 D/D information: Temperature in degree C
1.3.6.1.4.1.4756.20.732.20.1.233Columnf2000EASFx4DDPWRMarginRemoteBread-onlycurrentf2000EAS Series card fiber4 D/D information: Power margin
1.3.6.1.4.1.4756.20.732.20.1.234Columnf2000EASFx4DDPWRLossRemoteBread-onlycurrentf2000EAS Series card fiber4 D/D information: Power loss
1.3.6.1.4.1.4756.20.732.20.1.235Columnf2000EASTestRemoteBread-onlycurrentf2000EAS Series card test led sts: 0: Off 1: On
1.3.6.1.4.1.4756.20.732.20.1.236Columnf2000EASClearPortCounterRemoteBread-writecurrentf2000EAS Series card clear port counter: 0: Off 1: Action
1.3.6.1.4.1.4756.20.732.20.1.237Columnf2000EASAggrSourceMACAddrRemoteBread-writecurrentf2000EAS Series card Aggregation Mode Configuration: Source MAC Address 0: No 1: Yes
1.3.6.1.4.1.4756.20.732.20.1.238Columnf2000EASAggrDestinationMACAddrRemoteBread-writecurrentf2000EAS Series card Aggregation Mode Configuration: Destination MAC Address 0: No 1: Yes
1.3.6.1.4.1.4756.20.732.20.1.239Columnf2000EASAggrIPAddrRemoteBread-writecurrentf2000EAS Series card Aggregation Mode Configuration: IP Address 0: No 1: Yes
1.3.6.1.4.1.4756.20.732.20.1.240Columnf2000EASAggrTCPUDPPortNumRemoteBread-writecurrentf2000EAS Series card Aggregation Mode Configuration: TCP/UDP Port Number 0: No 1: Yes
1.3.6.1.4.1.4756.20.732.20.1.241Columnf2000EASAggrGroupPort1ConfRemoteBread-writecurrentf2000EAS Series card Aggregation Group Port1 Configuration: 0: Normal 1: ID1 2: ID2
1.3.6.1.4.1.4756.20.732.20.1.242Columnf2000EASAggrGroupPort2ConfRemoteBread-writecurrentf2000EAS Series card Aggregation Group Port2 Configuration: 0: Normal 1: ID1 2: ID2
1.3.6.1.4.1.4756.20.732.20.1.243Columnf2000EASAggrGroupPort3ConfRemoteBread-writecurrentf2000EAS Series card Aggregation Group Port3 Configuration: 0: Normal 1: ID1 2: ID2
1.3.6.1.4.1.4756.20.732.20.1.244Columnf2000EASAggrGroupPort4ConfRemoteBread-writecurrentf2000EAS Series card Aggregation Group Port4 Configuration: 0: Normal 1: ID1 2: ID2
1.3.6.1.4.1.4756.20.732.20.1.245Columnf2000EASPort1LACPEnabledRemoteBread-writecurrentf2000EAS Series card Port1 LACP Enabled: 0: No 1: Yes
1.3.6.1.4.1.4756.20.732.20.1.246Columnf2000EASPort1LACPKEYRemoteBread-writecurrentf2000EAS Series card Port1 LACP Key value: The Key value incurred by the port, range 0-65535.The value of 0 means auto.
1.3.6.1.4.1.4756.20.732.20.1.247Columnf2000EASPort1LACPRoleRemoteBread-writecurrentf2000EAS Series card Port1 LACP Role: 0: Passive 1: Active
1.3.6.1.4.1.4756.20.732.20.1.248Columnf2000EASPort1LACPTimeOutRemoteBread-writecurrentf2000EAS Series card Port1 LACP Time out: 0: Slow 1: Fast
1.3.6.1.4.1.4756.20.732.20.1.249Columnf2000EASPort1LACPPrioRemoteBread-writecurrentf2000EAS Series card Port1 LACP priority: The Key value incurred by the port, range 1-65535.
1.3.6.1.4.1.4756.20.732.20.1.250Columnf2000EASPort2LACPEnabledRemoteBread-writecurrentf2000EAS Series card Port2 LACP Enabled: 0: No 1: Yes
1.3.6.1.4.1.4756.20.732.20.1.251Columnf2000EASPort2LACPKEYRemoteBread-writecurrentf2000EAS Series card Port2 LACP Key value: The Key value incurred by the port, range 0-65535.The value of 0 means auto.
1.3.6.1.4.1.4756.20.732.20.1.252Columnf2000EASPort2LACPRoleRemoteBread-writecurrentf2000EAS Series card Port2 LACP Role: 0: Passive 1: Active
1.3.6.1.4.1.4756.20.732.20.1.253Columnf2000EASPort2LACPTimeOutRemoteBread-writecurrentf2000EAS Series card Port2 LACP Time out: 0: Slow 1: Fast
1.3.6.1.4.1.4756.20.732.20.1.254Columnf2000EASPort2LACPPrioRemoteBread-writecurrentf2000EAS Series card Port2 LACP priority: The Key value incurred by the port, range 1-65535.
1.3.6.1.4.1.4756.20.732.20.1.255Columnf2000EASPort3LACPEnabledRemoteBread-writecurrentf2000EAS Series card Port3 LACP Enabled: 0: No 1: Yes
1.3.6.1.4.1.4756.20.732.20.1.256Columnf2000EASPort3LACPKEYRemoteBread-writecurrentf2000EAS Series card Port3 LACP Key value: The Key value incurred by the port, range 0-65535.The value of 0 means auto.
1.3.6.1.4.1.4756.20.732.20.1.257Columnf2000EASPort3LACPRoleRemoteBread-writecurrentf2000EAS Series card Port3 LACP Role: 0: Passive 1: Active
1.3.6.1.4.1.4756.20.732.20.1.258Columnf2000EASPort3LACPTimeOutRemoteBread-writecurrentf2000EAS Series card Port3 LACP Time out: 0: Slow 1: Fast
1.3.6.1.4.1.4756.20.732.20.1.259Columnf2000EASPort3LACPPrioRemoteBread-writecurrentf2000EAS Series card Port3 LACP priority: The Key value incurred by the port, range 1-65535.
1.3.6.1.4.1.4756.20.732.20.1.260Columnf2000EASPort4LACPEnabledRemoteBread-writecurrentf2000EAS Series card Port4 LACP Enabled: 0: No 1: Yes
1.3.6.1.4.1.4756.20.732.20.1.261Columnf2000EASPort4LACPKEYRemoteBread-writecurrentf2000EAS Series card Port4 LACP Key value: The Key value incurred by the port, range 0-65535.The value of 0 means auto.
1.3.6.1.4.1.4756.20.732.20.1.262Columnf2000EASPort4LACPRoleRemoteBread-writecurrentf2000EAS Series card Port4 LACP Role: 0: Passive 1: Active
1.3.6.1.4.1.4756.20.732.20.1.263Columnf2000EASPort4LACPTimeOutRemoteBread-writecurrentf2000EAS Series card Port4 LACP Time out: 0: Slow 1: Fast
1.3.6.1.4.1.4756.20.732.20.1.264Columnf2000EASPort4LACPPrioRemoteBread-writecurrentf2000EAS Series card Port4 LACP priority: The Key value incurred by the port, range 1-65535.
1.3.6.1.4.1.4756.20.732.20.1.265Columnf2000EASPort1LACPstsRemoteBread-onlycurrentf2000EAS Series card Port1 LACP status: 0: No 1: Yes 2: Standby
1.3.6.1.4.1.4756.20.732.20.1.266Columnf2000EASPort1LACPKEYstsRemoteBread-onlycurrentf2000EAS Series card Port1 LACP status: Key
1.3.6.1.4.1.4756.20.732.20.1.267Columnf2000EASPort1LACPAggrIDstsRemoteBread-onlycurrentf2000EAS Series card Port1 LACP status: Aggr ID
1.3.6.1.4.1.4756.20.732.20.1.268Columnf2000EASPort1LACPParnterSysIDstsRemoteBread-onlycurrentf2000EAS Series card Port1 LACP status: Parnter System ID
1.3.6.1.4.1.4756.20.732.20.1.269Columnf2000EASPort1LACPParnterPortstsRemoteBread-onlycurrentf2000EAS Series card Port1 LACP status: Parnter Port Status
1.3.6.1.4.1.4756.20.732.20.1.270Columnf2000EASPort1LACPParnterProistsRemoteBread-onlycurrentf2000EAS Series card Port1 LACP status: Parnter Priority
1.3.6.1.4.1.4756.20.732.20.1.271Columnf2000EASPort2LACPstsRemoteBread-onlycurrentf2000EAS Series card Port2 LACP status: 0: No 1: Yes 2: Standby
1.3.6.1.4.1.4756.20.732.20.1.272Columnf2000EASPort2LACPKEYstsRemoteBread-onlycurrentf2000EAS Series card Port2 LACP status: Key
1.3.6.1.4.1.4756.20.732.20.1.273Columnf2000EASPort2LACPAggrIDstsRemoteBread-onlycurrentf2000EAS Series card Port2 LACP status: Aggr ID
1.3.6.1.4.1.4756.20.732.20.1.274Columnf2000EASPort2LACPParnterSysIDstsRemoteBread-onlycurrentf2000EAS Series card Port2 LACP status: Parnter System ID
1.3.6.1.4.1.4756.20.732.20.1.275Columnf2000EASPort2LACPParnterPortstsRemoteBread-onlycurrentf2000EAS Series card Port2 LACP status: Parnter Port Status
1.3.6.1.4.1.4756.20.732.20.1.276Columnf2000EASPort2LACPParnterProistsRemoteBread-onlycurrentf2000EAS Series card Port2 LACP status: Parnter Priority
1.3.6.1.4.1.4756.20.732.20.1.277Columnf2000EASPort3LACPstsRemoteBread-onlycurrentf2000EAS Series card Port3 LACP status: 0: No 1: Yes 2: Standby
1.3.6.1.4.1.4756.20.732.20.1.278Columnf2000EASPort3LACPKEYstsRemoteBread-onlycurrentf2000EAS Series card Port3 LACP status: Key
1.3.6.1.4.1.4756.20.732.20.1.279Columnf2000EASPort3LACPAggrIDstsRemoteBread-onlycurrentf2000EAS Series card Port3 LACP status: Aggr ID
1.3.6.1.4.1.4756.20.732.20.1.280Columnf2000EASPort3LACPParnterSysIDstsRemoteBread-onlycurrentf2000EAS Series card Port3 LACP status: Parnter System ID
1.3.6.1.4.1.4756.20.732.20.1.281Columnf2000EASPort3LACPParnterPortstsRemoteBread-onlycurrentf2000EAS Series card Port3 LACP status: Parnter Port Status
1.3.6.1.4.1.4756.20.732.20.1.282Columnf2000EASPort3LACPParnterProistsRemoteBread-onlycurrentf2000EAS Series card Port3 LACP status: Parnter Priority
1.3.6.1.4.1.4756.20.732.20.1.283Columnf2000EASPort4LACPstsRemoteBread-onlycurrentf2000EAS Series card Port4 LACP status: 0: No 1: Yes 2: Standby
1.3.6.1.4.1.4756.20.732.20.1.284Columnf2000EASPort4LACPKEYstsRemoteBread-onlycurrentf2000EAS Series card Port4 LACP status: Key
1.3.6.1.4.1.4756.20.732.20.1.285Columnf2000EASPort4LACPAggrIDstsRemoteBread-onlycurrentf2000EAS Series card Port4 LACP status: Aggr ID
1.3.6.1.4.1.4756.20.732.20.1.286Columnf2000EASPort4LACPParnterSysIDstsRemoteBread-onlycurrentf2000EAS Series card Port4 LACP status: Parnter System ID
1.3.6.1.4.1.4756.20.732.20.1.287Columnf2000EASPort4LACPParnterPortstsRemoteBread-onlycurrentf2000EAS Series card Port4 LACP status: Parnter Port Status
1.3.6.1.4.1.4756.20.732.20.1.288Columnf2000EASPort4LACPParnterProistsRemoteBread-onlycurrentf2000EAS Series card Port4 LACP status: Parnter Priority
1.3.6.1.4.1.4756.20.732.20.1.289Columnf2000EASOAMPort1EnableRemoteBread-onlycurrentf2000EAS Series card Port1 OAM: 0: Off 1: On
1.3.6.1.4.1.4756.20.732.20.1.290Columnf2000EASOAMPort1ModeRemoteBread-writecurrentf2000EAS Series card Port1 OAM: 0: Passive 1: Active
1.3.6.1.4.1.4756.20.732.20.1.291Columnf2000EASOAMPort1LoopBackRemoteBread-writecurrentf2000EAS Series card Port1 OAM LoopBack: 0: Off 1: On
1.3.6.1.4.1.4756.20.732.20.1.292Columnf2000EASOAMPort1LinkMonitorRemoteBread-writecurrentf2000EAS Series card Port1 OAM Link Monitor: 0: Off 1: On
1.3.6.1.4.1.4756.20.732.20.1.293Columnf2000EASOAMPort1MIBRetrievalRemoteBread-writecurrentf2000EAS Series card Port1 OAM MIB Retrieval: 0: Off 1: On
1.3.6.1.4.1.4756.20.732.20.1.294Columnf2000EASOAMPort1LoopBackOPRemoteBread-onlycurrentf2000EAS Series card Port1 OAM LoopBack operation: 0: Off 1: On
1.3.6.1.4.1.4756.20.732.20.1.295Columnf2000EASOAMPort2EnableRemoteBread-onlycurrentf2000EAS Series card Port2 OAM: 0: Off 1: On
1.3.6.1.4.1.4756.20.732.20.1.296Columnf2000EASOAMPort2ModeRemoteBread-writecurrentf2000EAS Series card Port2 OAM: 0: Passive 1: Active
1.3.6.1.4.1.4756.20.732.20.1.297Columnf2000EASOAMPort2LoopBackRemoteBread-writecurrentf2000EAS Series card Port2 OAM LoopBack: 0: Off 1: On
1.3.6.1.4.1.4756.20.732.20.1.298Columnf2000EASOAMPort2LinkMonitorRemoteBread-writecurrentf2000EAS Series card Port2 OAM Link Monitor: 0: Off 1: On
1.3.6.1.4.1.4756.20.732.20.1.299Columnf2000EASOAMPort2MIBRetrievalRemoteBread-writecurrentf2000EAS Series card Port2 OAM MIB Retrieval: 0: Off 1: On
1.3.6.1.4.1.4756.20.732.20.1.300Columnf2000EASOAMPort2LoopBackOPRemoteBread-onlycurrentf2000EAS Series card Port2 OAM LoopBack operation: 0: Off 1: On
1.3.6.1.4.1.4756.20.732.20.1.301Columnf2000EASOAMPort3EnableRemoteBread-onlycurrentf2000EAS Series card Port3 OAM: 0: Off 1: On
1.3.6.1.4.1.4756.20.732.20.1.302Columnf2000EASOAMPort3ModeRemoteBread-writecurrentf2000EAS Series card Port3 OAM: 0: Passive 1: Active
1.3.6.1.4.1.4756.20.732.20.1.303Columnf2000EASOAMPort3LoopBackRemoteBread-writecurrentf2000EAS Series card Port3 OAM: 0: Off 1: On
1.3.6.1.4.1.4756.20.732.20.1.304Columnf2000EASOAMPort3LinkMonitorRemoteBread-writecurrentf2000EAS Series card Port3 OAM Link Monitor: 0: Off 1: On
1.3.6.1.4.1.4756.20.732.20.1.305Columnf2000EASOAMPort3MIBRetrievalRemoteBread-writecurrentf2000EAS Series card Port3 OAM MIB Retrieval: 0: Off 1: On
1.3.6.1.4.1.4756.20.732.20.1.306Columnf2000EASOAMPort3LoopBackOPRemoteBread-onlycurrentf2000EAS Series card Port3 OAM LoopBack operation: 0: Disable 1: Enable
1.3.6.1.4.1.4756.20.732.20.1.307Columnf2000EASOAMPort4EnableRemoteBread-onlycurrentf2000EAS Series card Port4 OAM: 0: Off 1: On
1.3.6.1.4.1.4756.20.732.20.1.308Columnf2000EASOAMPort4ModeRemoteBread-writecurrentf2000EAS Series card Port4 OAM: 0: Passive 1: Active
1.3.6.1.4.1.4756.20.732.20.1.309Columnf2000EASOAMPort4LoopBackRemoteBread-writecurrentf2000EAS Series card Port4 OAM: 0: Off 1: On
1.3.6.1.4.1.4756.20.732.20.1.310Columnf2000EASOAMPort4LinkMonitorRemoteBread-writecurrentf2000EAS Series card Port4 OAM Link Monitor: 0: Off 1: On
1.3.6.1.4.1.4756.20.732.20.1.311Columnf2000EASOAMPort4MIBRetrievalRemoteBread-writecurrentf2000EAS Series card Port4 OAM MIB Retrieval: 0: Off 1: On
1.3.6.1.4.1.4756.20.732.20.1.312Columnf2000EASOAMPort4LoopBackOPRemoteBread-onlycurrentf2000EAS Series card Port4 OAM LoopBack operation: 0: On 1: Off
1.3.6.1.4.1.4756.20.732.20.1.313Columnf2000EASPort1EFEErrorWindowRemoteBread-writecurrentf2000EAS Series card Port1 Link Event Configuration: Error Frame Event - Error Window
1.3.6.1.4.1.4756.20.732.20.1.314Columnf2000EASPort1EFEErrorThresholdRemoteBread-writecurrentf2000EAS Series card Port1 Link Event Configuration: Error Frame Event - Error Threshold
1.3.6.1.4.1.4756.20.732.20.1.315Columnf2000EASPort1SPEEErrorWindowRemoteBread-writecurrentf2000EAS Series card Port1 Link Event Configuration: Symbol Period Error Event - Error Window
1.3.6.1.4.1.4756.20.732.20.1.316Columnf2000EASPort1SPEEErrorThresholdRemoteBread-writecurrentf2000EAS Series card Port1 Link Event Configuration: Symbol Period Error Event - Error Threshold
1.3.6.1.4.1.4756.20.732.20.1.317Columnf2000EASPort1SSEErrorWindowRemoteBread-writecurrentf2000EAS Series card Port1 Link Event Configuration: Seconds Summary Event - Error Window
1.3.6.1.4.1.4756.20.732.20.1.318Columnf2000EASPort1SSEErrorThresholdRemoteBread-writecurrentf2000EAS Series card Port1 Link Event Configuration: Seconds Summary Event - Error Threshold
1.3.6.1.4.1.4756.20.732.20.1.319Columnf2000EASPort2EFEErrorWindowRemoteBread-writecurrentf2000EAS Series card Port2 Link Event Configuration: Error Frame Event - Error Window
1.3.6.1.4.1.4756.20.732.20.1.320Columnf2000EASPort2EFEErrorThresholdRemoteBread-writecurrentf2000EAS Series card Port2 Link Event Configuration: Error Frame Event - Error Threshold
1.3.6.1.4.1.4756.20.732.20.1.321Columnf2000EASPort2SPEEErrorWindowRemoteBread-writecurrentf2000EAS Series card Port2 Link Event Configuration: Symbol Period Error Event - Error Window
1.3.6.1.4.1.4756.20.732.20.1.322Columnf2000EASPort2SPEEErrorThresholdRemoteBread-writecurrentf2000EAS Series card Port2 Link Event Configuration: Symbol Period Error Event - Error Threshold
1.3.6.1.4.1.4756.20.732.20.1.323Columnf2000EASPort2SSEErrorWindowRemoteBread-writecurrentf2000EAS Series card Port2 Link Event Configuration: Seconds Summary Event - Error Window
1.3.6.1.4.1.4756.20.732.20.1.324Columnf2000EASPort2SSEErrorThresholdRemoteBread-writecurrentf2000EAS Series card Port2 Link Event Configuration: Seconds Summary Event - Error Threshold
1.3.6.1.4.1.4756.20.732.20.1.325Columnf2000EASPort3EFEErrorWindowRemoteBread-writecurrentf2000EAS Series card Port3 Link Event Configuration: Error Frame Event - Error Window
1.3.6.1.4.1.4756.20.732.20.1.326Columnf2000EASPort3EFEErrorThresholdRemoteBread-writecurrentf2000EAS Series card Port3 Link Event Configuration: Error Frame Event - Error Threshold
1.3.6.1.4.1.4756.20.732.20.1.327Columnf2000EASPort3SPEEErrorWindowRemoteBread-writecurrentf2000EAS Series card Port3 Link Event Configuration: Symbol Period Error Event - Error Window
1.3.6.1.4.1.4756.20.732.20.1.328Columnf2000EASPort3SPEEErrorThresholdRemoteBread-writecurrentf2000EAS Series card Port3 Link Event Configuration: Symbol Period Error Event - Error Threshold
1.3.6.1.4.1.4756.20.732.20.1.329Columnf2000EASPort3SSEErrorWindowRemoteBread-writecurrentf2000EAS Series card Port3 Link Event Configuration: Seconds Summary Event - Error Window
1.3.6.1.4.1.4756.20.732.20.1.330Columnf2000EASPort3SSEErrorThresholdRemoteBread-writecurrentf2000EAS Series card Port3 Link Event Configuration: Seconds Summary Event - Error Threshold
1.3.6.1.4.1.4756.20.732.20.1.331Columnf2000EASPort4EFEErrorWindowRemoteBread-writecurrentf2000EAS Series card Port4 Link Event Configuration: Error Frame Event - Error Window
1.3.6.1.4.1.4756.20.732.20.1.332Columnf2000EASPort4EFEErrorThresholdRemoteBread-writecurrentf2000EAS Series card Port4 Link Event Configuration: Error Frame Event - Error Threshold
1.3.6.1.4.1.4756.20.732.20.1.333Columnf2000EASPort4SPEEErrorWindowRemoteBread-writecurrentf2000EAS Series card Port4 Link Event Configuration: Symbol Period Error Event - Error Window
1.3.6.1.4.1.4756.20.732.20.1.334Columnf2000EASPort4SPEEErrorThresholdRemoteBread-writecurrentf2000EAS Series card Port4 Link Event Configuration: Symbol Period Error Event - Error Threshold
1.3.6.1.4.1.4756.20.732.20.1.335Columnf2000EASPort4SSEErrorWindowRemoteBread-writecurrentf2000EAS Series card Port4 Link Event Configuration: Seconds Summary Event - Error Window
1.3.6.1.4.1.4756.20.732.20.1.336Columnf2000EASPort4SSEErrorThresholdRemoteBread-writecurrentf2000EAS Series card Port4 Link Event Configuration: Seconds Summary Event - Error Threshold
1.3.6.1.4.1.4756.20.732.20.1.337Columnf2000EASPort1RxOAMInfoPDURemoteBread-onlycurrentf2000EAS Series card Port1 Detailed Link OAM Statistics: Rx OAM Information PDU's
1.3.6.1.4.1.4756.20.732.20.1.338Columnf2000EASPort1RxUniqueErrorEventRemoteBread-onlycurrentf2000EAS Series card Port1 Detailed Link OAM Statistics: Rx Unique Error Event Notificatio
1.3.6.1.4.1.4756.20.732.20.1.339Columnf2000EASPort1RxDuplicateErrorEventRemoteBread-onlycurrentf2000EAS Series card Port1 Detailed Link OAM Statistics: Rx Duplicate Error Event Notification
1.3.6.1.4.1.4756.20.732.20.1.340Columnf2000EASPort1RxLoopBackControlRemoteBread-onlycurrentf2000EAS Series card Port1 Detailed Link OAM Statistics: Rx Loopback Control
1.3.6.1.4.1.4756.20.732.20.1.341Columnf2000EASPort1RxVariableRequestRemoteBread-onlycurrentf2000EAS Series card Port1 Detailed Link OAM Statistics: Rx Variable Request
1.3.6.1.4.1.4756.20.732.20.1.342Columnf2000EASPort1RxVariableResponseRemoteBread-onlycurrentf2000EAS Series card Port1 Detailed Link OAM Statistics: Rx Variable Response
1.3.6.1.4.1.4756.20.732.20.1.343Columnf2000EASPort1RxOrgSpecificPDURemoteBread-onlycurrentf2000EAS Series card Port1 Detailed Link OAM Statistics: Rx Org Specific PDU's
1.3.6.1.4.1.4756.20.732.20.1.344Columnf2000EASPort1RxUnsupportedCodesRemoteBread-onlycurrentf2000EAS Series card Port1 Detailed Link OAM Statistics: Rx Unsupported Codes
1.3.6.1.4.1.4756.20.732.20.1.345Columnf2000EASPort1RxLinkFaultPDURemoteBread-onlycurrentf2000EAS Series card Port1 Detailed Link OAM Statistics: Rx Link Fault PDU's
1.3.6.1.4.1.4756.20.732.20.1.346Columnf2000EASPort1RxDyingGaspRemoteBread-onlycurrentf2000EAS Series card Port1 Detailed Link OAM Statistics: Rx Dying Gasp
1.3.6.1.4.1.4756.20.732.20.1.347Columnf2000EASPort1RxCriticalEventPDURemoteBread-onlycurrentf2000EAS Series card Port1 Detailed Link OAM Statistics: Rx Dying Gasp
1.3.6.1.4.1.4756.20.732.20.1.348Columnf2000EASPort1TxOAMInfoPDURemoteBread-onlycurrentf2000EAS Series card Port1 Detailed Link OAM Statistics: Tx OAM Information PDU's
1.3.6.1.4.1.4756.20.732.20.1.349Columnf2000EASPort1TxUniqueErrorEventRemoteBread-onlycurrentf2000EAS Series card Port1 Detailed Link OAM Statistics: Tx Unique Error Event Notificatio
1.3.6.1.4.1.4756.20.732.20.1.350Columnf2000EASPort1TxDuplicateErrorEventRemoteBread-onlycurrentf2000EAS Series card Port1 Detailed Link OAM Statistics: Tx Duplicate Error Event Notification
1.3.6.1.4.1.4756.20.732.20.1.351Columnf2000EASPort1TxLoopBackControlRemoteBread-onlycurrentf2000EAS Series card Port1 Detailed Link OAM Statistics: Tx Loopback Control
1.3.6.1.4.1.4756.20.732.20.1.352Columnf2000EASPort1TxVariableRequestRemoteBread-onlycurrentf2000EAS Series card Port1 Detailed Link OAM Statistics: Tx Variable Request
1.3.6.1.4.1.4756.20.732.20.1.353Columnf2000EASPort1TxVariableResponseRemoteBread-onlycurrentf2000EAS Series card Port1 Detailed Link OAM Statistics: Tx Variable Response
1.3.6.1.4.1.4756.20.732.20.1.354Columnf2000EASPort1TxOrgSpecificPDURemoteBread-onlycurrentf2000EAS Series card Port1 Detailed Link OAM Statistics: Tx Org Specific PDU's
1.3.6.1.4.1.4756.20.732.20.1.355Columnf2000EASPort1TxUnsupportedCodesRemoteBread-onlycurrentf2000EAS Series card Port1 Detailed Link OAM Statistics: Tx Unsupported Codes
1.3.6.1.4.1.4756.20.732.20.1.356Columnf2000EASPort1TxLinkFaultPDURemoteBread-onlycurrentf2000EAS Series card Port1 Detailed Link OAM Statistics: Tx Link Fault PDU's
1.3.6.1.4.1.4756.20.732.20.1.357Columnf2000EASPort1TxDyingGaspRemoteBread-onlycurrentf2000EAS Series card Port1 Detailed Link OAM Statistics: Tx Dying Gasp
1.3.6.1.4.1.4756.20.732.20.1.358Columnf2000EASPort1TxCriticalEventPDURemoteBread-onlycurrentf2000EAS Series card Port1 Detailed Link OAM Statistics: Tx Dying Gasp
1.3.6.1.4.1.4756.20.732.20.1.359Columnf2000EASPort2RxOAMInfoPDURemoteBread-onlycurrentf2000EAS Series card Port2 Detailed Link OAM Statistics: Rx OAM Information PDU's
1.3.6.1.4.1.4756.20.732.20.1.360Columnf2000EASPort2RxUniqueErrorEventRemoteBread-onlycurrentf2000EAS Series card Port2 Detailed Link OAM Statistics: Rx Unique Error Event Notificatio
1.3.6.1.4.1.4756.20.732.20.1.361Columnf2000EASPort2RxDuplicateErrorEventRemoteBread-onlycurrentf2000EAS Series card Port2 Detailed Link OAM Statistics: Rx Duplicate Error Event Notification
1.3.6.1.4.1.4756.20.732.20.1.362Columnf2000EASPort2RxLoopBackControlRemoteBread-onlycurrentf2000EAS Series card Port2 Detailed Link OAM Statistics: Rx Loopback Control
1.3.6.1.4.1.4756.20.732.20.1.363Columnf2000EASPort2RxVariableRequestRemoteBread-onlycurrentf2000EAS Series card Port2 Detailed Link OAM Statistics: Rx Variable Request
1.3.6.1.4.1.4756.20.732.20.1.364Columnf2000EASPort2RxVariableResponseRemoteBread-onlycurrentf2000EAS Series card Port2 Detailed Link OAM Statistics: Rx Variable Response
1.3.6.1.4.1.4756.20.732.20.1.365Columnf2000EASPort2RxOrgSpecificPDURemoteBread-onlycurrentf2000EAS Series card Port2 Detailed Link OAM Statistics: Rx Org Specific PDU's
1.3.6.1.4.1.4756.20.732.20.1.366Columnf2000EASPort2RxUnsupportedCodesRemoteBread-onlycurrentf2000EAS Series card Port2 Detailed Link OAM Statistics: Rx Unsupported Codes
1.3.6.1.4.1.4756.20.732.20.1.367Columnf2000EASPort2RxLinkFaultPDURemoteBread-onlycurrentf2000EAS Series card Port2 Detailed Link OAM Statistics: Rx Link Fault PDU's
1.3.6.1.4.1.4756.20.732.20.1.368Columnf2000EASPort2RxDyingGaspRemoteBread-onlycurrentf2000EAS Series card Port2 Detailed Link OAM Statistics: Rx Dying Gasp
1.3.6.1.4.1.4756.20.732.20.1.369Columnf2000EASPort2RxCriticalEventPDURemoteBread-onlycurrentf2000EAS Series card Port2 Detailed Link OAM Statistics: Rx Dying Gasp
1.3.6.1.4.1.4756.20.732.20.1.370Columnf2000EASPort2TxOAMInfoPDURemoteBread-onlycurrentf2000EAS Series card Port2 Detailed Link OAM Statistics: Tx OAM Information PDU's
1.3.6.1.4.1.4756.20.732.20.1.371Columnf2000EASPort2TxUniqueErrorEventRemoteBread-onlycurrentf2000EAS Series card Port2 Detailed Link OAM Statistics: Tx Unique Error Event Notificatio
1.3.6.1.4.1.4756.20.732.20.1.372Columnf2000EASPort2TxDuplicateErrorEventRemoteBread-onlycurrentf2000EAS Series card Port2 Detailed Link OAM Statistics: Tx Duplicate Error Event Notification
1.3.6.1.4.1.4756.20.732.20.1.373Columnf2000EASPort2TxLoopBackControlRemoteBread-onlycurrentf2000EAS Series card Port2 Detailed Link OAM Statistics: Tx Loopback Control
1.3.6.1.4.1.4756.20.732.20.1.374Columnf2000EASPort2TxVariableRequestRemoteBread-onlycurrentf2000EAS Series card Port2 Detailed Link OAM Statistics: Tx Variable Request
1.3.6.1.4.1.4756.20.732.20.1.375Columnf2000EASPort2TxVariableResponseRemoteBread-onlycurrentf2000EAS Series card Port2 Detailed Link OAM Statistics: Tx Variable Response
1.3.6.1.4.1.4756.20.732.20.1.376Columnf2000EASPort2TxOrgSpecificPDURemoteBread-onlycurrentf2000EAS Series card Port2 Detailed Link OAM Statistics: Tx Org Specific PDU's
1.3.6.1.4.1.4756.20.732.20.1.377Columnf2000EASPort2TxUnsupportedCodesRemoteBread-onlycurrentf2000EAS Series card Port2 Detailed Link OAM Statistics: Tx Unsupported Codes
1.3.6.1.4.1.4756.20.732.20.1.378Columnf2000EASPort2TxLinkFaultPDURemoteBread-onlycurrentf2000EAS Series card Port2 Detailed Link OAM Statistics: Tx Link Fault PDU's
1.3.6.1.4.1.4756.20.732.20.1.379Columnf2000EASPort2TxDyingGaspRemoteBread-onlycurrentf2000EAS Series card Port2 Detailed Link OAM Statistics: Tx Dying Gasp
1.3.6.1.4.1.4756.20.732.20.1.380Columnf2000EASPort2TxCriticalEventPDURemoteBread-onlycurrentf2000EAS Series card Port2 Detailed Link OAM Statistics: Tx Dying Gasp
1.3.6.1.4.1.4756.20.732.20.1.381Columnf2000EASPort3RxOAMInfoPDURemoteBread-onlycurrentf2000EAS Series card Port3 Detailed Link OAM Statistics: Rx OAM Information PDU's
1.3.6.1.4.1.4756.20.732.20.1.382Columnf2000EASPort3RxUniqueErrorEventRemoteBread-onlycurrentf2000EAS Series card Port3 Detailed Link OAM Statistics: Rx Unique Error Event Notificatio
1.3.6.1.4.1.4756.20.732.20.1.383Columnf2000EASPort3RxDuplicateErrorEventRemoteBread-onlycurrentf2000EAS Series card Port3 Detailed Link OAM Statistics: Rx Duplicate Error Event Notification
1.3.6.1.4.1.4756.20.732.20.1.384Columnf2000EASPort3RxLoopBackControlRemoteBread-onlycurrentf2000EAS Series card Port3 Detailed Link OAM Statistics: Rx Loopback Control
1.3.6.1.4.1.4756.20.732.20.1.385Columnf2000EASPort3RxVariableRequestRemoteBread-onlycurrentf2000EAS Series card Port3 Detailed Link OAM Statistics: Rx Variable Request
1.3.6.1.4.1.4756.20.732.20.1.386Columnf2000EASPort3RxVariableResponseRemoteBread-onlycurrentf2000EAS Series card Port3 Detailed Link OAM Statistics: Rx Variable Response
1.3.6.1.4.1.4756.20.732.20.1.387Columnf2000EASPort3RxOrgSpecificPDURemoteBread-onlycurrentf2000EAS Series card Port3 Detailed Link OAM Statistics: Rx Org Specific PDU's
1.3.6.1.4.1.4756.20.732.20.1.388Columnf2000EASPort3RxUnsupportedCodesRemoteBread-onlycurrentf2000EAS Series card Port3 Detailed Link OAM Statistics: Rx Unsupported Codes
1.3.6.1.4.1.4756.20.732.20.1.389Columnf2000EASPort3RxLinkFaultPDURemoteBread-onlycurrentf2000EAS Series card Port3 Detailed Link OAM Statistics: Rx Link Fault PDU's
1.3.6.1.4.1.4756.20.732.20.1.390Columnf2000EASPort3RxDyingGaspRemoteBread-onlycurrentf2000EAS Series card Port3 Detailed Link OAM Statistics: Rx Dying Gasp
1.3.6.1.4.1.4756.20.732.20.1.391Columnf2000EASPort3RxCriticalEventPDURemoteBread-onlycurrentf2000EAS Series card Port3 Detailed Link OAM Statistics: Rx Dying Gasp
1.3.6.1.4.1.4756.20.732.20.1.392Columnf2000EASPort3TxOAMInfoPDURemoteBread-onlycurrentf2000EAS Series card Port3 Detailed Link OAM Statistics: Tx OAM Information PDU's
1.3.6.1.4.1.4756.20.732.20.1.393Columnf2000EASPort3TxUniqueErrorEventRemoteBread-onlycurrentf2000EAS Series card Port3 Detailed Link OAM Statistics: Tx Unique Error Event Notificatio
1.3.6.1.4.1.4756.20.732.20.1.394Columnf2000EASPort3TxDuplicateErrorEventRemoteBread-onlycurrentf2000EAS Series card Port3 Detailed Link OAM Statistics: Tx Duplicate Error Event Notification
1.3.6.1.4.1.4756.20.732.20.1.395Columnf2000EASPort3TxLoopBackControlRemoteBread-onlycurrentf2000EAS Series card Port3 Detailed Link OAM Statistics: Tx Loopback Control
1.3.6.1.4.1.4756.20.732.20.1.396Columnf2000EASPort3TxVariableRequestRemoteBread-onlycurrentf2000EAS Series card Port3 Detailed Link OAM Statistics: Tx Variable Request
1.3.6.1.4.1.4756.20.732.20.1.397Columnf2000EASPort3TxVariableResponseRemoteBread-onlycurrentf2000EAS Series card Port3 Detailed Link OAM Statistics: Tx Variable Response
1.3.6.1.4.1.4756.20.732.20.1.398Columnf2000EASPort3TxOrgSpecificPDURemoteBread-onlycurrentf2000EAS Series card Port3 Detailed Link OAM Statistics: Tx Org Specific PDU's
1.3.6.1.4.1.4756.20.732.20.1.399Columnf2000EASPort3TxUnsupportedCodesRemoteBread-onlycurrentf2000EAS Series card Port3 Detailed Link OAM Statistics: Tx Unsupported Codes
1.3.6.1.4.1.4756.20.732.20.1.400Columnf2000EASPort3TxLinkFaultPDURemoteBread-onlycurrentf2000EAS Series card Port3 Detailed Link OAM Statistics: Tx Link Fault PDU's
1.3.6.1.4.1.4756.20.732.20.1.401Columnf2000EASPort3TxDyingGaspRemoteBread-onlycurrentf2000EAS Series card Port3 Detailed Link OAM Statistics: Tx Dying Gasp
1.3.6.1.4.1.4756.20.732.20.1.402Columnf2000EASPort3TxCriticalEventPDURemoteBread-onlycurrentf2000EAS Series card Port3 Detailed Link OAM Statistics: Tx Dying Gasp
1.3.6.1.4.1.4756.20.732.20.1.403Columnf2000EASPort4RxOAMInfoPDURemoteBread-onlycurrentf2000EAS Series card Port4 Detailed Link OAM Statistics: Rx OAM Information PDU's
1.3.6.1.4.1.4756.20.732.20.1.404Columnf2000EASPort4RxUniqueErrorEventRemoteBread-onlycurrentf2000EAS Series card Port4 Detailed Link OAM Statistics: Rx Unique Error Event Notificatio
1.3.6.1.4.1.4756.20.732.20.1.405Columnf2000EASPort4RxDuplicateErrorEventRemoteBread-onlycurrentf2000EAS Series card Port4 Detailed Link OAM Statistics: Rx Duplicate Error Event Notification
1.3.6.1.4.1.4756.20.732.20.1.406Columnf2000EASPort4RxLoopBackControlRemoteBread-onlycurrentf2000EAS Series card Port4 Detailed Link OAM Statistics: Rx Loopback Control
1.3.6.1.4.1.4756.20.732.20.1.407Columnf2000EASPort4RxVariableRequestRemoteBread-onlycurrentf2000EAS Series card Port4 Detailed Link OAM Statistics: Rx Variable Request
1.3.6.1.4.1.4756.20.732.20.1.408Columnf2000EASPort4RxVariableResponseRemoteBread-onlycurrentf2000EAS Series card Port4 Detailed Link OAM Statistics: Rx Variable Response
1.3.6.1.4.1.4756.20.732.20.1.409Columnf2000EASPort4RxOrgSpecificPDURemoteBread-onlycurrentf2000EAS Series card Port4 Detailed Link OAM Statistics: Rx Org Specific PDU's
1.3.6.1.4.1.4756.20.732.20.1.410Columnf2000EASPort4RxUnsupportedCodesRemoteBread-onlycurrentf2000EAS Series card Port4 Detailed Link OAM Statistics: Rx Unsupported Codes
1.3.6.1.4.1.4756.20.732.20.1.411Columnf2000EASPort4RxLinkFaultPDURemoteBread-onlycurrentf2000EAS Series card Port4 Detailed Link OAM Statistics: Rx Link Fault PDU's
1.3.6.1.4.1.4756.20.732.20.1.412Columnf2000EASPort4RxDyingGaspRemoteBread-onlycurrentf2000EAS Series card Port4 Detailed Link OAM Statistics: Rx Dying Gasp
1.3.6.1.4.1.4756.20.732.20.1.413Columnf2000EASPort4RxCriticalEventPDURemoteBread-onlycurrentf2000EAS Series card Port4 Detailed Link OAM Statistics: Rx Dying Gasp
1.3.6.1.4.1.4756.20.732.20.1.414Columnf2000EASPort4TxOAMInfoPDURemoteBread-onlycurrentf2000EAS Series card Port4 Detailed Link OAM Statistics: Tx OAM Information PDU's
1.3.6.1.4.1.4756.20.732.20.1.415Columnf2000EASPort4TxUniqueErrorEventRemoteBread-onlycurrentf2000EAS Series card Port4 Detailed Link OAM Statistics: Tx Unique Error Event Notificatio
1.3.6.1.4.1.4756.20.732.20.1.416Columnf2000EASPort4TxDuplicateErrorEventRemoteBread-onlycurrentf2000EAS Series card Port4 Detailed Link OAM Statistics: Tx Duplicate Error Event Notification
1.3.6.1.4.1.4756.20.732.20.1.417Columnf2000EASPort4TxLoopBackControlRemoteBread-onlycurrentf2000EAS Series card Port4 Detailed Link OAM Statistics: Tx Loopback Control
1.3.6.1.4.1.4756.20.732.20.1.418Columnf2000EASPort4TxVariableRequestRemoteBread-onlycurrentf2000EAS Series card Port4 Detailed Link OAM Statistics: Tx Variable Request
1.3.6.1.4.1.4756.20.732.20.1.419Columnf2000EASPort4TxVariableResponseRemoteBread-onlycurrentf2000EAS Series card Port4 Detailed Link OAM Statistics: Tx Variable Response
1.3.6.1.4.1.4756.20.732.20.1.420Columnf2000EASPort4TxOrgSpecificPDURemoteBread-onlycurrentf2000EAS Series card Port4 Detailed Link OAM Statistics: Tx Org Specific PDU's
1.3.6.1.4.1.4756.20.732.20.1.421Columnf2000EASPort4TxUnsupportedCodesRemoteBread-onlycurrentf2000EAS Series card Port4 Detailed Link OAM Statistics: Tx Unsupported Codes
1.3.6.1.4.1.4756.20.732.20.1.422Columnf2000EASPort4TxLinkFaultPDURemoteBread-onlycurrentf2000EAS Series card Port4 Detailed Link OAM Statistics: Tx Link Fault PDU's
1.3.6.1.4.1.4756.20.732.20.1.423Columnf2000EASPort4TxDyingGaspRemoteBread-onlycurrentf2000EAS Series card Port4 Detailed Link OAM Statistics: Tx Dying Gasp
1.3.6.1.4.1.4756.20.732.20.1.424Columnf2000EASPort4TxCriticalEventPDURemoteBread-onlycurrentf2000EAS Series card Port4 Detailed Link OAM Statistics: Tx Dying Gasp
1.3.6.1.4.1.4756.20.732.20.1.425Columnf2000EASPort1PDUPermisionRemoteBread-onlycurrentf2000EAS Series card Detailed Link OAM Status for Port 1: PDU Permission
1.3.6.1.4.1.4756.20.732.20.1.426Columnf2000EASPort1DiscoveryStateRemoteBread-onlycurrentf2000EAS Series card Detailed Link OAM Status for Port 1: Discovery State
1.3.6.1.4.1.4756.20.732.20.1.427Columnf2000EASPort1PeerMACAddrRemoteBread-onlycurrentf2000EAS Series card Detailed Link OAM Status for Port 1: Discovery State
1.3.6.1.4.1.4756.20.732.20.1.428Columnf2000EASPort1LocalModeRemoteBread-onlycurrentf2000EAS Series card Detailed Link OAM Status for Port 1: RemoteB: Mode
1.3.6.1.4.1.4756.20.732.20.1.429Columnf2000EASPort1LocalUnOperationRemoteBread-onlycurrentf2000EAS Series card Detailed Link OAM Status for Port 1: RemoteB: Unidirectional Operation Support
1.3.6.1.4.1.4756.20.732.20.1.430Columnf2000EASPort1LocalRemoteLbRemoteBread-onlycurrentf2000EAS Series card Detailed Link OAM Status for Port 1: RemoteB: Remote Loopback Support
1.3.6.1.4.1.4756.20.732.20.1.431Columnf2000EASPort1LocalLMRemoteBread-onlycurrentf2000EAS Series card Detailed Link OAM Status for Port 1: RemoteB: Link Monitoring Support
1.3.6.1.4.1.4756.20.732.20.1.432Columnf2000EASPort1LocalMIBRetrievalRemoteBread-onlycurrentf2000EAS Series card Detailed Link OAM Status for Port 1: RemoteB: MIB Retrieval Support
1.3.6.1.4.1.4756.20.732.20.1.433Columnf2000EASPort1LocalMTUSizeRemoteBread-onlycurrentf2000EAS Series card Detailed Link OAM Status for Port 1: RemoteB: MTU Size
1.3.6.1.4.1.4756.20.732.20.1.434Columnf2000EASPort1LocalMultiStateRemoteBread-onlycurrentf2000EAS Series card Detailed Link OAM Status for Port 1: RemoteB: Multiplexer State
1.3.6.1.4.1.4756.20.732.20.1.435Columnf2000EASPort1LocalParserStateRemoteBread-onlycurrentf2000EAS Series card Detailed Link OAM Status for Port 1: RemoteB: Multiplexer State
1.3.6.1.4.1.4756.20.732.20.1.436Columnf2000EASPort1LocalOUIRemoteBread-onlycurrentf2000EAS Series card Detailed Link OAM Status for Port 1: RemoteB: Organizational Unique Identification
1.3.6.1.4.1.4756.20.732.20.1.437Columnf2000EASPort1LocalPDURevRemoteBread-onlycurrentf2000EAS Series card Detailed Link OAM Status for Port 1: RemoteB: PDU Revision
1.3.6.1.4.1.4756.20.732.20.1.438Columnf2000EASPort1PeerModeRemoteBread-onlycurrentf2000EAS Series card Detailed Link OAM Status for Port 1: Peer: Mode
1.3.6.1.4.1.4756.20.732.20.1.439Columnf2000EASPort1PeerUnOperationRemoteBread-onlycurrentf2000EAS Series card Detailed Link OAM Status for Port 1: Peer: Unidirectional Operation Support
1.3.6.1.4.1.4756.20.732.20.1.440Columnf2000EASPort1PeerRemoteLbRemoteBread-onlycurrentf2000EAS Series card Detailed Link OAM Status for Port 1: Peer: Remote Loopback Support
1.3.6.1.4.1.4756.20.732.20.1.441Columnf2000EASPort1PeerLMRemoteBread-onlycurrentf2000EAS Series card Detailed Link OAM Status for Port 1: Peer: Link Monitoring Support
1.3.6.1.4.1.4756.20.732.20.1.442Columnf2000EASPort1PeerMIBRetrievalRemoteBread-onlycurrentf2000EAS Series card Detailed Link OAM Status for Port 1: Peer: MIB Retrieval Support
1.3.6.1.4.1.4756.20.732.20.1.443Columnf2000EASPort1PeerMTUSizeRemoteBread-onlycurrentf2000EAS Series card Detailed Link OAM Status for Port 1: Peer: MTU Size
1.3.6.1.4.1.4756.20.732.20.1.444Columnf2000EASPort1PeerMultiStateRemoteBread-onlycurrentf2000EAS Series card Detailed Link OAM Status for Port 1: Peer: Multiplexer State
1.3.6.1.4.1.4756.20.732.20.1.445Columnf2000EASPort1PeerParserStateRemoteBread-onlycurrentf2000EAS Series card Detailed Link OAM Status for Port 1: Peer: Multiplexer State
1.3.6.1.4.1.4756.20.732.20.1.446Columnf2000EASPort1PeerOUIRemoteBread-onlycurrentf2000EAS Series card Detailed Link OAM Status for Port 1: Peer: Organizational Unique Identification
1.3.6.1.4.1.4756.20.732.20.1.447Columnf2000EASPort1PeerPDURevRemoteBread-onlycurrentf2000EAS Series card Detailed Link OAM Status for Port 1: Peer: PDU Revision
1.3.6.1.4.1.4756.20.732.20.1.448Columnf2000EASPort2PDUPermisionRemoteBread-onlycurrentf2000EAS Series card Detailed Link OAM Status for Port 2: PDU Permission
1.3.6.1.4.1.4756.20.732.20.1.449Columnf2000EASPort2DiscoveryStateRemoteBread-onlycurrentf2000EAS Series card Detailed Link OAM Status for Port 2: Discovery State
1.3.6.1.4.1.4756.20.732.20.1.450Columnf2000EASPort2PeerMACAddrRemoteBread-onlycurrentf2000EAS Series card Detailed Link OAM Status for Port 2: Discovery State
1.3.6.1.4.1.4756.20.732.20.1.451Columnf2000EASPort2LocalModeRemoteBread-onlycurrentf2000EAS Series card Detailed Link OAM Status for Port 2: RemoteB: Mode
1.3.6.1.4.1.4756.20.732.20.1.452Columnf2000EASPort2LocalUnOperationRemoteBread-onlycurrentf2000EAS Series card Detailed Link OAM Status for Port 2: RemoteB: Unidirectional Operation Support
1.3.6.1.4.1.4756.20.732.20.1.453Columnf2000EASPort2LocalRemoteLbRemoteBread-onlycurrentf2000EAS Series card Detailed Link OAM Status for Port 2: RemoteB: Remote Loopback Support
1.3.6.1.4.1.4756.20.732.20.1.454Columnf2000EASPort2LocalLMRemoteBread-onlycurrentf2000EAS Series card Detailed Link OAM Status for Port 2: RemoteB: Link Monitoring Support
1.3.6.1.4.1.4756.20.732.20.1.455Columnf2000EASPort2LocalMIBRetrievalRemoteBread-onlycurrentf2000EAS Series card Detailed Link OAM Status for Port 2: RemoteB: MIB Retrieval Support
1.3.6.1.4.1.4756.20.732.20.1.456Columnf2000EASPort2LocalMTUSizeRemoteBread-onlycurrentf2000EAS Series card Detailed Link OAM Status for Port 2: RemoteB: MTU Size
1.3.6.1.4.1.4756.20.732.20.1.457Columnf2000EASPort2LocalMultiStateRemoteBread-onlycurrentf2000EAS Series card Detailed Link OAM Status for Port 2: RemoteB: Multiplexer State
1.3.6.1.4.1.4756.20.732.20.1.458Columnf2000EASPort2LocalParserStateRemoteBread-onlycurrentf2000EAS Series card Detailed Link OAM Status for Port 2: RemoteB: Multiplexer State
1.3.6.1.4.1.4756.20.732.20.1.459Columnf2000EASPort2LocalOUIRemoteBread-onlycurrentf2000EAS Series card Detailed Link OAM Status for Port 2: RemoteB: Organizational Unique Identification
1.3.6.1.4.1.4756.20.732.20.1.460Columnf2000EASPort2LocalPDURevRemoteBread-onlycurrentf2000EAS Series card Detailed Link OAM Status for Port 2: RemoteB: PDU Revision
1.3.6.1.4.1.4756.20.732.20.1.461Columnf2000EASPort2PeerModeRemoteBread-onlycurrentf2000EAS Series card Detailed Link OAM Status for Port 2: Peer: Mode
1.3.6.1.4.1.4756.20.732.20.1.462Columnf2000EASPort2PeerUnOperationRemoteBread-onlycurrentf2000EAS Series card Detailed Link OAM Status for Port 2: Peer: Unidirectional Operation Support
1.3.6.1.4.1.4756.20.732.20.1.463Columnf2000EASPort2PeerRemoteLbRemoteBread-onlycurrentf2000EAS Series card Detailed Link OAM Status for Port 2: Peer: Remote Loopback Support
1.3.6.1.4.1.4756.20.732.20.1.464Columnf2000EASPort2PeerLMRemoteBread-onlycurrentf2000EAS Series card Detailed Link OAM Status for Port 2: Peer: Link Monitoring Support
1.3.6.1.4.1.4756.20.732.20.1.465Columnf2000EASPort2PeerMIBRetrievalRemoteBread-onlycurrentf2000EAS Series card Detailed Link OAM Status for Port 2: Peer: MIB Retrieval Support
1.3.6.1.4.1.4756.20.732.20.1.466Columnf2000EASPort2PeerMTUSizeRemoteBread-onlycurrentf2000EAS Series card Detailed Link OAM Status for Port 2: Peer: MTU Size
1.3.6.1.4.1.4756.20.732.20.1.467Columnf2000EASPort2PeerMultiStateRemoteBread-onlycurrentf2000EAS Series card Detailed Link OAM Status for Port 2: Peer: Multiplexer State
1.3.6.1.4.1.4756.20.732.20.1.468Columnf2000EASPort2PeerParserStateRemoteBread-onlycurrentf2000EAS Series card Detailed Link OAM Status for Port 2: Peer: Multiplexer State
1.3.6.1.4.1.4756.20.732.20.1.469Columnf2000EASPort2PeerOUIRemoteBread-onlycurrentf2000EAS Series card Detailed Link OAM Status for Port 2: Peer: Organizational Unique Identification
1.3.6.1.4.1.4756.20.732.20.1.470Columnf2000EASPort2PeerPDURevRemoteBread-onlycurrentf2000EAS Series card Detailed Link OAM Status for Port 2: Peer: PDU Revision
1.3.6.1.4.1.4756.20.732.20.1.471Columnf2000EASPort3PDUPermisionRemoteBread-onlycurrentf2000EAS Series card Detailed Link OAM Status for Port 3: PDU Permission
1.3.6.1.4.1.4756.20.732.20.1.472Columnf2000EASPort3DiscoveryStateRemoteBread-onlycurrentf2000EAS Series card Detailed Link OAM Status for Port 3: Discovery State
1.3.6.1.4.1.4756.20.732.20.1.473Columnf2000EASPort3PeerMACAddrRemoteBread-onlycurrentf2000EAS Series card Detailed Link OAM Status for Port 3: Discovery State
1.3.6.1.4.1.4756.20.732.20.1.474Columnf2000EASPort3LocalModeRemoteBread-onlycurrentf2000EAS Series card Detailed Link OAM Status for Port 3: RemoteB: Mode
1.3.6.1.4.1.4756.20.732.20.1.475Columnf2000EASPort3LocalUnOperationRemoteBread-onlycurrentf2000EAS Series card Detailed Link OAM Status for Port 3: RemoteB: Unidirectional Operation Support
1.3.6.1.4.1.4756.20.732.20.1.476Columnf2000EASPort3LocalRemoteLbRemoteBread-onlycurrentf2000EAS Series card Detailed Link OAM Status for Port 3: RemoteB: Remote Loopback Support
1.3.6.1.4.1.4756.20.732.20.1.477Columnf2000EASPort3LocalLMRemoteBread-onlycurrentf2000EAS Series card Detailed Link OAM Status for Port 3: RemoteB: Link Monitoring Support
1.3.6.1.4.1.4756.20.732.20.1.478Columnf2000EASPort3LocalMIBRetrievalRemoteBread-onlycurrentf2000EAS Series card Detailed Link OAM Status for Port 3: RemoteB: MIB Retrieval Support
1.3.6.1.4.1.4756.20.732.20.1.479Columnf2000EASPort3LocalMTUSizeRemoteBread-onlycurrentf2000EAS Series card Detailed Link OAM Status for Port 3: RemoteB: MTU Size
1.3.6.1.4.1.4756.20.732.20.1.480Columnf2000EASPort3LocalMultiStateRemoteBread-onlycurrentf2000EAS Series card Detailed Link OAM Status for Port 3: RemoteB: Multiplexer State
1.3.6.1.4.1.4756.20.732.20.1.481Columnf2000EASPort3LocalParserStateRemoteBread-onlycurrentf2000EAS Series card Detailed Link OAM Status for Port 3: RemoteB: Multiplexer State
1.3.6.1.4.1.4756.20.732.20.1.482Columnf2000EASPort3LocalOUIRemoteBread-onlycurrentf2000EAS Series card Detailed Link OAM Status for Port 3: RemoteB: Organizational Unique Identification
1.3.6.1.4.1.4756.20.732.20.1.483Columnf2000EASPort3LocalPDURevRemoteBread-onlycurrentf2000EAS Series card Detailed Link OAM Status for Port 3: RemoteB: PDU Revision
1.3.6.1.4.1.4756.20.732.20.1.484Columnf2000EASPort3PeerModeRemoteBread-onlycurrentf2000EAS Series card Detailed Link OAM Status for Port 3: Peer: Mode
1.3.6.1.4.1.4756.20.732.20.1.485Columnf2000EASPort3PeerUnOperationRemoteBread-onlycurrentf2000EAS Series card Detailed Link OAM Status for Port 3: Peer: Unidirectional Operation Support
1.3.6.1.4.1.4756.20.732.20.1.486Columnf2000EASPort3PeerRemoteLbRemoteBread-onlycurrentf2000EAS Series card Detailed Link OAM Status for Port 3: Peer: Remote Loopback Support
1.3.6.1.4.1.4756.20.732.20.1.487Columnf2000EASPort3PeerLMRemoteBread-onlycurrentf2000EAS Series card Detailed Link OAM Status for Port 3: Peer: Link Monitoring Support
1.3.6.1.4.1.4756.20.732.20.1.488Columnf2000EASPort3PeerMIBRetrievalRemoteBread-onlycurrentf2000EAS Series card Detailed Link OAM Status for Port 3: Peer: MIB Retrieval Support
1.3.6.1.4.1.4756.20.732.20.1.489Columnf2000EASPort3PeerMTUSizeRemoteBread-onlycurrentf2000EAS Series card Detailed Link OAM Status for Port 3: Peer: MTU Size
1.3.6.1.4.1.4756.20.732.20.1.490Columnf2000EASPort3PeerMultiStateRemoteBread-onlycurrentf2000EAS Series card Detailed Link OAM Status for Port 3: Peer: Multiplexer State
1.3.6.1.4.1.4756.20.732.20.1.491Columnf2000EASPort3PeerParserStateRemoteBread-onlycurrentf2000EAS Series card Detailed Link OAM Status for Port 3: Peer: Multiplexer State
1.3.6.1.4.1.4756.20.732.20.1.492Columnf2000EASPort3PeerOUIRemoteBread-onlycurrentf2000EAS Series card Detailed Link OAM Status for Port 3: Peer: Organizational Unique Identification
1.3.6.1.4.1.4756.20.732.20.1.493Columnf2000EASPort3PeerPDURevRemoteBread-onlycurrentf2000EAS Series card Detailed Link OAM Status for Port 3: Peer: PDU Revision
1.3.6.1.4.1.4756.20.732.20.1.494Columnf2000EASPort4PDUPermisionRemoteBread-onlycurrentf2000EAS Series card Detailed Link OAM Status for Port 4: PDU Permission
1.3.6.1.4.1.4756.20.732.20.1.495Columnf2000EASPort4DiscoveryStateRemoteBread-onlycurrentf2000EAS Series card Detailed Link OAM Status for Port 4: Discovery State
1.3.6.1.4.1.4756.20.732.20.1.496Columnf2000EASPort4PeerMACAddrRemoteBread-onlycurrentf2000EAS Series card Detailed Link OAM Status for Port 4: Discovery State
1.3.6.1.4.1.4756.20.732.20.1.497Columnf2000EASPort4LocalModeRemoteBread-onlycurrentf2000EAS Series card Detailed Link OAM Status for Port 4: RemoteB: Mode
1.3.6.1.4.1.4756.20.732.20.1.498Columnf2000EASPort4LocalUnOperationRemoteBread-onlycurrentf2000EAS Series card Detailed Link OAM Status for Port 4: RemoteB: Unidirectional Operation Support
1.3.6.1.4.1.4756.20.732.20.1.499Columnf2000EASPort4LocalRemoteLbRemoteBread-onlycurrentf2000EAS Series card Detailed Link OAM Status for Port 4: RemoteB: Remote Loopback Support
1.3.6.1.4.1.4756.20.732.20.1.500Columnf2000EASPort4LocalLMRemoteBread-onlycurrentf2000EAS Series card Detailed Link OAM Status for Port 4: RemoteB: Link Monitoring Support
1.3.6.1.4.1.4756.20.732.20.1.501Columnf2000EASPort4LocalMIBRetrievalRemoteBread-onlycurrentf2000EAS Series card Detailed Link OAM Status for Port 4: RemoteB: MIB Retrieval Support
1.3.6.1.4.1.4756.20.732.20.1.502Columnf2000EASPort4LocalMTUSizeRemoteBread-onlycurrentf2000EAS Series card Detailed Link OAM Status for Port 4: RemoteB: MTU Size
1.3.6.1.4.1.4756.20.732.20.1.503Columnf2000EASPort4LocalMultiStateRemoteBread-onlycurrentf2000EAS Series card Detailed Link OAM Status for Port 4: RemoteB: Multiplexer State
1.3.6.1.4.1.4756.20.732.20.1.504Columnf2000EASPort4LocalParserStateRemoteBread-onlycurrentf2000EAS Series card Detailed Link OAM Status for Port 4: RemoteB: Multiplexer State
1.3.6.1.4.1.4756.20.732.20.1.505Columnf2000EASPort4LocalOUIRemoteBread-onlycurrentf2000EAS Series card Detailed Link OAM Status for Port 4: RemoteB: Organizational Unique Identification
1.3.6.1.4.1.4756.20.732.20.1.506Columnf2000EASPort4LocalPDURevRemoteBread-onlycurrentf2000EAS Series card Detailed Link OAM Status for Port 4: RemoteB: PDU Revision
1.3.6.1.4.1.4756.20.732.20.1.507Columnf2000EASPort4PeerModeRemoteBread-onlycurrentf2000EAS Series card Detailed Link OAM Status for Port 4: Peer: Mode
1.3.6.1.4.1.4756.20.732.20.1.508Columnf2000EASPort4PeerUnOperationRemoteBread-onlycurrentf2000EAS Series card Detailed Link OAM Status for Port 4: Peer: Unidirectional Operation Support
1.3.6.1.4.1.4756.20.732.20.1.509Columnf2000EASPort4PeerRemoteLbRemoteBread-onlycurrentf2000EAS Series card Detailed Link OAM Status for Port 4: Peer: Remote Loopback Support
1.3.6.1.4.1.4756.20.732.20.1.510Columnf2000EASPort4PeerLMRemoteBread-onlycurrentf2000EAS Series card Detailed Link OAM Status for Port 4: Peer: Link Monitoring Support
1.3.6.1.4.1.4756.20.732.20.1.511Columnf2000EASPort4PeerMIBRetrievalRemoteBread-onlycurrentf2000EAS Series card Detailed Link OAM Status for Port 4: Peer: MIB Retrieval Support
1.3.6.1.4.1.4756.20.732.20.1.512Columnf2000EASPort4PeerMTUSizeRemoteBread-onlycurrentEDD Series card Detailed Link OAM Status for Port 4: Peer: MTU Size
1.3.6.1.4.1.4756.20.732.20.1.513Columnf2000EASPort4PeerMultiStateRemoteBread-onlycurrentf2000EAS Series card Detailed Link OAM Status for Port 4: Peer: Multiplexer State
1.3.6.1.4.1.4756.20.732.20.1.514Columnf2000EASPort4PeerParserStateRemoteBread-onlycurrentf2000EAS Series card Detailed Link OAM Status for Port 4: Peer: Multiplexer State
1.3.6.1.4.1.4756.20.732.20.1.515Columnf2000EASPort4PeerOUIRemoteBread-onlycurrentf2000EAS Series card Detailed Link OAM Status for Port 4: Peer: Organizational Unique Identification
1.3.6.1.4.1.4756.20.732.20.1.516Columnf2000EASPort4PeerPDURevRemoteBread-onlycurrentf2000EAS Series card Detailed Link OAM Status for Port 4: Peer: PDU Revision
1.3.6.1.4.1.4756.20.732.20.1.517Columnf2000EASCLEAROAMCOUNTERRemoteBread-writecurrentf2000EAS Series card Clear OAM Counter: 0: Off 1: Action
1.3.6.1.4.1.4756.20.732.20.1.518Columnf2000EASLoopProtectionEnableRemoteBread-writecurrentf2000EAS Series card Loop Protection Configuration: General Settings - Enable Loop Protection 0: Disable 1: Enable
1.3.6.1.4.1.4756.20.732.20.1.519Columnf2000EASLoopProtectionTxTimeRemoteBread-writecurrentf2000EAS Series card Loop Protection Configuration: General Settings - Transmission Time
1.3.6.1.4.1.4756.20.732.20.1.520Columnf2000EASLoopProtectionShutdownTimeRemoteBread-writecurrentf2000EAS Series card Loop Protection Configuration: General Settings - Shutdown Time
1.3.6.1.4.1.4756.20.732.20.1.521Columnf2000EASLoopProtectionPort1EnabledRemoteBread-writecurrentf2000EAS Series card Loop Protection Configuration for Port 1: Port Configuration - Enable 0: Disable 1: Enable
1.3.6.1.4.1.4756.20.732.20.1.522Columnf2000EASLoopProtectionPort1ActionRemoteBread-writecurrentf2000EAS Series card Loop Protection Configuration for Port 1: Port Configuration - Action 0: Shutdown Port 1: Shutdown Port And Log 2: Log Only
1.3.6.1.4.1.4756.20.732.20.1.523Columnf2000EASLoopProtectionPort1TxModeRemoteBread-writecurrentf2000EAS Series card Loop Protection Configuration for Port 1: Port Configuration - Tx Mode 0: Disable 1: Enable
1.3.6.1.4.1.4756.20.732.20.1.524Columnf2000EASLoopProtectionPort2EnabledRemoteBread-writecurrentf2000EAS Series card Loop Protection Configuration for Port 2: Port Configuration - Enable 0: Disable 1: Enable
1.3.6.1.4.1.4756.20.732.20.1.525Columnf2000EASLoopProtectionPort2ActionRemoteBread-writecurrentf2000EAS Series card Loop Protection Configuration for Port 2: Port Configuration - Action 0: Shutdown Port 1: Shutdown Port And Log 2: Log Only
1.3.6.1.4.1.4756.20.732.20.1.526Columnf2000EASLoopProtectionPort2TxModeRemoteBread-writecurrentf2000EAS Series card Loop Protection Configuration for Port 2: Port Configuration - Tx Mode 0: Disable 1: Enable
1.3.6.1.4.1.4756.20.732.20.1.527Columnf2000EASLoopProtectionPort3EnabledRemoteBread-writecurrentf2000EASE Series card Loop Protection Configuration for Port 3: Port Configuration - Enable 0: Disable 1: Enable
1.3.6.1.4.1.4756.20.732.20.1.528Columnf2000EASLoopProtectionPort3ActionRemoteBread-writecurrentf2000EAS Series card Loop Protection Configuration for Port 3: Port Configuration - Action 0: Shutdown Port 1: Shutdown Port And Log 2: Log Only
1.3.6.1.4.1.4756.20.732.20.1.529Columnf2000EASLoopProtectionPort3TxModeRemoteBread-writecurrentf2000EAS Series card Loop Protection Configuration for Port 3: Port Configuration - Tx Mode 0: Disable 1: Enable
1.3.6.1.4.1.4756.20.732.20.1.530Columnf2000EASLoopProtectionPort4EnabledRemoteBread-writecurrentf2000EAS Series card Loop Protection Configuration for Port 4: Port Configuration - Enable 0: Disable 1: Enable
1.3.6.1.4.1.4756.20.732.20.1.531Columnf2000EASLoopProtectionPort4ActionRemoteBread-writecurrentf2000EAS Series card Loop Protection Configuration for Port 4: Port Configuration - Action 0: Shutdown Port 1: Shutdown Port And Log 2: Log Only
1.3.6.1.4.1.4756.20.732.20.1.532Columnf2000EASLoopProtectionPort4TxModeRemoteBread-writecurrentf2000EAS Series card Loop Protection Configuration for Port 41: Port Configuration - Tx Mode 0: Disable 1: Enable
1.3.6.1.4.1.4756.20.732.20.1.533Columnf2000EASLoopProtectionPort1ActionStsRemoteBread-onlycurrentf2000EAS Series card Loop Protection Status for Port 1: Action
1.3.6.1.4.1.4756.20.732.20.1.534Columnf2000EASLoopProtectionPort1TransStsRemoteBread-onlycurrentf2000EAS Series card Loop Protection Status for Port 1: Transmit
1.3.6.1.4.1.4756.20.732.20.1.535Columnf2000EASLoopProtectionPort1LoopsStsRemoteBread-onlycurrentf2000EAS Series card Loop Protection Status for Port 1: Loops
1.3.6.1.4.1.4756.20.732.20.1.536Columnf2000EASLoopProtectionPort1StatusRemoteBread-onlycurrentf2000EAS Series card Loop Protection Status for Port 1: Status
1.3.6.1.4.1.4756.20.732.20.1.537Columnf2000EASLoopProtectionPort1LoopStsRemoteBread-onlycurrentf2000EAS Series card Loop Protection Status for Port 1: Loop
1.3.6.1.4.1.4756.20.732.20.1.538Columnf2000EASLoopProtectionPort2ActionStsRemoteBread-onlycurrentf2000EAS Series card Loop Protection Status for Port 2: Action
1.3.6.1.4.1.4756.20.732.20.1.539Columnf2000EASLoopProtectionPort2TransStsRemoteBread-onlycurrentf2000EAS Series card Loop Protection Status for Port 2: Transmit
1.3.6.1.4.1.4756.20.732.20.1.540Columnf2000EASLoopProtectionPort2LoopsStsRemoteBread-onlycurrentf2000EAS Series card Loop Protection Status for Port 2: Loops
1.3.6.1.4.1.4756.20.732.20.1.541Columnf2000EASLoopProtectionPort2StatusRemoteBread-onlycurrentf2000EAS Series card Loop Protection Status for Port 2: Status
1.3.6.1.4.1.4756.20.732.20.1.542Columnf2000EASLoopProtectionPort2LoopStsRemoteBread-onlycurrentf2000EAS Series card Loop Protection Status for Port 2: Loop
1.3.6.1.4.1.4756.20.732.20.1.543Columnf2000EASLoopProtectionPort3ActionStsRemoteBread-onlycurrentf2000EAS Series card Loop Protection Status for Port 3: Action
1.3.6.1.4.1.4756.20.732.20.1.544Columnf2000EASLoopProtectionPort3TransStsRemoteBread-onlycurrentf2000EAS Series card Loop Protection Status for Port 3: Transmit
1.3.6.1.4.1.4756.20.732.20.1.545Columnf2000EASLoopProtectionPort3LoopsStsRemoteBread-onlycurrentf2000EAS Series card Loop Protection Status for Port 3: Loops
1.3.6.1.4.1.4756.20.732.20.1.546Columnf2000EASLoopProtectionPort3StatusRemoteBread-onlycurrentf2000EAS Series card Loop Protection Status for Port 3: Status
1.3.6.1.4.1.4756.20.732.20.1.547Columnf2000EASLoopProtectionPort3LoopStsRemoteBread-onlycurrentf2000EAS Series card Loop Protection Status for Port 3: Loop
1.3.6.1.4.1.4756.20.732.20.1.548Columnf2000EASLoopProtectionPort4ActionStsRemoteBread-onlycurrentf2000EAS Series card Loop Protection Status for Port 4: Action
1.3.6.1.4.1.4756.20.732.20.1.549Columnf2000EASLoopProtectionPort4TransStsRemoteBread-onlycurrentf2000EAS Series card Loop Protection Status for Port 4: Transmit
1.3.6.1.4.1.4756.20.732.20.1.550Columnf2000EASLoopProtectionPort4LoopsStsRemoteBread-onlycurrentf2000EAS Series card Loop Protection Status for Port 4: Loops
1.3.6.1.4.1.4756.20.732.20.1.551Columnf2000EASLoopProtectionPort4StatusRemoteBread-onlycurrentf2000EAS Series card Loop Protection Status for Port 4: Status
1.3.6.1.4.1.4756.20.732.20.1.552Columnf2000EASLoopProtectionPort4LoopStsRemoteBread-onlycurrentf2000EAS Series card Loop Protection Status for Port 4: Loop
1.3.6.1.4.1.4756.20.732.20.1.553Columnf2000EASSTPProtocolVersionRemoteBread-writecurrentf2000EAS Series card STP Bridge Configuration: Basic Settings - Protocol Version 0: STP 1: RSTP 2: MSTP
1.3.6.1.4.1.4756.20.732.20.1.554Columnf2000EASSTPBridgePriorityRemoteBread-writecurrentf2000EAS Series card STP Bridge Configuration: Basic Settings - Bridge Priority 0: 0 1: 4096 2: 8192 3: 12288 4: 16384 5: 20480 6: 24576 7: 28672 8: 32768 9: 3…
1.3.6.1.4.1.4756.20.732.20.1.555Columnf2000EASSTPForwardDelayRemoteBread-writecurrentf2000EAS Series card STP Bridge Configuration: Basic Settings - Forward Delay
1.3.6.1.4.1.4756.20.732.20.1.556Columnf2000EASSTPMaxAgeRemoteBread-writecurrentf2000EAS Series card STP Bridge Configuration: Basic Settings - Max Age
1.3.6.1.4.1.4756.20.732.20.1.557Columnf2000EASSTPMaximumHopCountRemoteBread-writecurrentf2000EAS Series card STP Bridge Configuration: Basic Settings - Maximum Hop Count
1.3.6.1.4.1.4756.20.732.20.1.558Columnf2000EASSTPTransmitHoldCountRemoteBread-writecurrentf2000EAS Series card STP Bridge Configuration: Basic Settings - Transmit Hold Count
1.3.6.1.4.1.4756.20.732.20.1.559Columnf2000EASSTPEdgePortBPDUFilteringRemoteBread-writecurrentf2000EAS Series card STP Bridge Configuration: Advanced Settings - Edge Port BPDU Filtering 0: Off 1: On
1.3.6.1.4.1.4756.20.732.20.1.560Columnf2000EASSTPEdgePortBPDUGuardRemoteBread-writecurrentf2000EAS Series card STP Bridge Configuration: Advanced Settings - Edge Port BPDU Guard 0: Off 1: On
1.3.6.1.4.1.4756.20.732.20.1.561Columnf2000EASSTPPortErrorRecoveryTimeoutRemoteBread-writecurrentf2000EAS Series card STP Bridge Configuration: Advanced Settings - Port Error Recovery Timeout 0: Off 1: On
1.3.6.1.4.1.4756.20.732.20.1.562Columnf2000EASMSTIConfigurationNameRemoteBread-writecurrentf2000EAS Series card MSTI Configuration: Configuration Identification - Configuration Name
1.3.6.1.4.1.4756.20.732.20.1.563Columnf2000EASMSTIConfigurationRevisionRemoteBread-writecurrentf2000EAS Series card MSTI Configuration: Configuration Identification - Configuration Revision
1.3.6.1.4.1.4756.20.732.20.1.564Columnf2000EASMSTI1VLANsMappingRemoteBread-writecurrentf2000EAS Series card MSTI Configuration: MSTI Mapping - MSTI 1
1.3.6.1.4.1.4756.20.732.20.1.565Columnf2000EASMSTI2VLANsMappingRemoteBread-writecurrentf2000EAS Series card MSTI Configuration: MSTI Mapping - MSTI 2
1.3.6.1.4.1.4756.20.732.20.1.566Columnf2000EASMSTI3VLANsMappingRemoteBread-writecurrentf2000EAS Series card MSTI Configuration: MSTI Mapping - MSTI 3
1.3.6.1.4.1.4756.20.732.20.1.567Columnf2000EASMSTI4VLANsMappingRemoteBread-writecurrentf2000EAS Series card MSTI Configuration: MSTI Mapping - MSTI 4
1.3.6.1.4.1.4756.20.732.20.1.568Columnf2000EASMSTI5VLANsMappingRemoteBread-writecurrentf2000EAS Series card MSTI Configuration: MSTI Mapping - MSTI 5
1.3.6.1.4.1.4756.20.732.20.1.569Columnf2000EASMSTI6VLANsMappingRemoteBread-writecurrentf2000EAS Series card MSTI Configuration: MSTI Mapping - MSTI 6
1.3.6.1.4.1.4756.20.732.20.1.570Columnf2000EASMSTI7VLANsMappingRemoteBread-writecurrentf2000EAS Series card MSTI Configuration: MSTI Mapping - MSTI 7
1.3.6.1.4.1.4756.20.732.20.1.571Columnf2000EASCISTAggregatedSTPEnabledRemoteBread-writecurrentf2000EAS Series card STP CIST Port Configuration: CIST Aggregated Port Configuration - STP Enabled
1.3.6.1.4.1.4756.20.732.20.1.572Columnf2000EASCISTAggregatedPathCostRemoteBread-writecurrentf2000EAS Series card STP CIST Port Configuration: CIST Aggregated Port Configuration - Path Cost Valid values are in the range 0 to 200000000. Setting 0 means …
1.3.6.1.4.1.4756.20.732.20.1.573Columnf2000EASCISTAggregatedPriorityRemoteBread-writecurrentf2000EAS Series card STP CIST Port Configuration: CIST Aggregated Port Configuration - Priority
1.3.6.1.4.1.4756.20.732.20.1.574Columnf2000EASCISTAggregatedAdminEdgeRemoteBread-writecurrentf2000EAS Series card STP CIST Port Configuration: CIST Aggregated Port Configuration - STP Enabled 0: Non-edge 1: Edge
1.3.6.1.4.1.4756.20.732.20.1.575Columnf2000EASCISTAggregatedAutoEdgeRemoteBread-writecurrentf2000EAS Series card STP CIST Port Configuration: CIST Aggregated Port Configuration - Auto Edge 0: Non-edge 1: Edge
1.3.6.1.4.1.4756.20.732.20.1.576Columnf2000EASCISTAggregatedRestrictedRoleRemoteBread-writecurrentf2000EAS Series card STP CIST Port Configuration: CIST Aggregated Port Configuration - Restricted Role 0: Non-edge 1: Edge
1.3.6.1.4.1.4756.20.732.20.1.577Columnf2000EASCISTAggregatedRestrictedTCNRemoteBread-writecurrentf2000EAS Series card STP CIST Port Configuration: CIST Aggregated Port Configuration - Restricted TCN 0: Non-edge 1: Edge
1.3.6.1.4.1.4756.20.732.20.1.578Columnf2000EASCISTAggregatedBPDUGuardRemoteBread-writecurrentf2000EAS Series card STP CIST Port Configuration: CIST Aggregated Port Configuration - BPDU Guard 0: Non-edge 1: Edge
1.3.6.1.4.1.4756.20.732.20.1.579Columnf2000EASCISTAggregatedPointToPointRemoteBread-writecurrentf2000EAS Series card STP CIST Port Configuration: CIST Aggregated Port Configuration - Point-to-point 0: Forced True 1: Forced False 2: Auto
1.3.6.1.4.1.4756.20.732.20.1.580Columnf2000EASCISTPort1STPEnabledRemoteBread-writecurrentf2000EAS Series card STP CIST Port Configuration: CIST Normal Port1 Configuration - STP Enabled
1.3.6.1.4.1.4756.20.732.20.1.581Columnf2000EASCISTPort1PathCostRemoteBread-writecurrentf2000EAS Series card STP CIST Port Configuration: CIST Normal Port1 Configuration - Path Cost Valid values are in the range 0 to 200000000. Setting 0 means Aut…
1.3.6.1.4.1.4756.20.732.20.1.582Columnf2000EASCISTPort1PriorityRemoteBread-writecurrentf2000EAS Series card STP CIST Port Configuration: CIST Normal Port1 Configuration - Priority
1.3.6.1.4.1.4756.20.732.20.1.583Columnf2000EASCISTPort1AdminEdgeRemoteBread-writecurrentf2000EAS Series card STP CIST Port Configuration: CIST Normal Port1 Configuration - STP Enabled 0: Non-edge 1: Edge
1.3.6.1.4.1.4756.20.732.20.1.584Columnf2000EASCISTPort1AutoEdgeRemoteBread-writecurrentf2000EAS Series card STP CIST Port Configuration: CIST Normal Port1 Configuration - Auto Edge 0: Non-edge 1: Edge
1.3.6.1.4.1.4756.20.732.20.1.585Columnf2000EASCISTPort1RestrictedRoleRemoteBread-writecurrentf2000EAS Series card STP CIST Port Configuration: CIST Normal Port1 Configuration - Restricted Role 0: Non-edge 1: Edge
1.3.6.1.4.1.4756.20.732.20.1.586Columnf2000EASCISTPort1RestrictedTCNRemoteBread-writecurrentf2000EAS Series card STP CIST Port Configuration: CIST Normal Port1 Configuration - Restricted TCN 0: Non-edge 1: Edge
1.3.6.1.4.1.4756.20.732.20.1.587Columnf2000EASCISTPort1BPDUGuardRemoteBread-writecurrentf2000EAS Series card STP CIST Port Configuration: CIST Normal Port1 Configuration - BPDU Guard 0: Non-edge 1: Edge
1.3.6.1.4.1.4756.20.732.20.1.588Columnf2000EASCISTPort1PointToPointRemoteBread-writecurrentf2000EAS Series card STP CIST Port Configuration: CIST Normal Port1 Configuration - Point-to-point 0: Forced True 1: Forced False 2: Auto
1.3.6.1.4.1.4756.20.732.20.1.589Columnf2000EASCISTPort2STPEnabledRemoteBread-writecurrentf2000EAS Series card STP CIST Port Configuration: CIST Normal Port2 Configuration - STP Enabled
1.3.6.1.4.1.4756.20.732.20.1.590Columnf2000EASCISTPort2PathCostRemoteBread-writecurrentf2000EAS Series card STP CIST Port Configuration: CIST Normal Port2 Configuration - Path Cost Valid values are in the range 0 to 200000000. Setting 0 means Aut…
1.3.6.1.4.1.4756.20.732.20.1.591Columnf2000EASCISTPort2PriorityRemoteBread-writecurrentf2000EAS Series card STP CIST Port Configuration: CIST Normal Port2 Configuration - Priority
1.3.6.1.4.1.4756.20.732.20.1.592Columnf2000EASCISTPort2AdminEdgeRemoteBread-writecurrentf2000EAS Series card STP CIST Port Configuration: CIST Normal Port2 Configuration - STP Enabled 0: Non-edge 1: Edge
1.3.6.1.4.1.4756.20.732.20.1.593Columnf2000EASCISTPort2AutoEdgeRemoteBread-writecurrentf2000EAS Series card STP CIST Port Configuration: CIST Normal Port2 Configuration - Auto Edge 0: Non-edge 1: Edge
1.3.6.1.4.1.4756.20.732.20.1.594Columnf2000EASCISTPort2RestrictedRoleRemoteBread-writecurrentf2000EAS Series card STP CIST Port Configuration: CIST Normal Port2 Configuration - Restricted Role 0: Non-edge 1: Edge
1.3.6.1.4.1.4756.20.732.20.1.595Columnf2000EASCISTPort2RestrictedTCNRemoteBread-writecurrentf2000EAS Series card STP CIST Port Configuration: CIST Normal Port2 Configuration - Restricted TCN 0: Non-edge 1: Edge
1.3.6.1.4.1.4756.20.732.20.1.596Columnf2000EASCISTPort2BPDUGuardRemoteBread-writecurrentf2000EAS Series card STP CIST Port Configuration: CIST Normal Port2 Configuration - BPDU Guard 0: Non-edge 1: Edge
1.3.6.1.4.1.4756.20.732.20.1.597Columnf2000EASCISTPort2PointToPointRemoteBread-writecurrentf2000EAS Series card STP CIST Port Configuration: CIST Normal Port2 Configuration - Point-to-point 0: Forced True 1: Forced False 2: Auto
1.3.6.1.4.1.4756.20.732.20.1.598Columnf2000EASCISTPort3STPEnabledRemoteBread-writecurrentf2000EAS Series card STP CIST Port Configuration: CIST Normal Port3 Configuration - STP Enabled
1.3.6.1.4.1.4756.20.732.20.1.599Columnf2000EASCISTPort3PathCostRemoteBread-writecurrentf2000EAS Series card STP CIST Port Configuration: CIST Normal Port3 Configuration - Path Cost Valid values are in the range 0 to 200000000. Setting 0 means Aut…
1.3.6.1.4.1.4756.20.732.20.1.600Columnf2000EASCISTPort3PriorityRemoteBread-writecurrentf2000EAS Series card STP CIST Port Configuration: CIST Normal Port3 Configuration - Priority
1.3.6.1.4.1.4756.20.732.20.1.601Columnf2000EASCISTPort3AdminEdgeRemoteBread-writecurrentf2000EAS Series card STP CIST Port Configuration: CIST Normal Port3 Configuration - STP Enabled 0: Non-edge 1: Edge
1.3.6.1.4.1.4756.20.732.20.1.602Columnf2000EASCISTPort3AutoEdgeRemoteBread-writecurrentf2000EAS Series card STP CIST Port Configuration: CIST Normal Port3 Configuration - Auto Edge 0: Non-edge 1: Edge
1.3.6.1.4.1.4756.20.732.20.1.603Columnf2000EASCISTPort3RestrictedRoleRemoteBread-writecurrentf2000EAS Series card STP CIST Port Configuration: CIST Normal Port3 Configuration - Restricted Role 0: Non-edge 1: Edge
1.3.6.1.4.1.4756.20.732.20.1.604Columnf2000EASCISTPort3RestrictedTCNRemoteBread-writecurrentf2000EAS Series card STP CIST Port Configuration: CIST Normal Port3 Configuration - Restricted TCN 0: Non-edge 1: Edge
1.3.6.1.4.1.4756.20.732.20.1.605Columnf2000EASCISTPort3BPDUGuardRemoteBread-writecurrentf2000EAS Series card STP CIST Port Configuration: CIST Normal Port3 Configuration - BPDU Guard 0: Non-edge 1: Edge
1.3.6.1.4.1.4756.20.732.20.1.606Columnf2000EASCISTPort3PointToPointRemoteBread-writecurrentf2000EAS Series card STP CIST Port Configuration: CIST Normal Port3 Configuration - Point-to-point 0: Forced True 1: Forced False 2: Auto
1.3.6.1.4.1.4756.20.732.20.1.607Columnf2000EASCISTPort4STPEnabledRemoteBread-writecurrentf2000EAS Series card STP CIST Port Configuration: CIST Normal Port4 Configuration - STP Enabled
1.3.6.1.4.1.4756.20.732.20.1.608Columnf2000EASCISTPort4PathCostRemoteBread-writecurrentf2000EAS Series card STP CIST Port Configuration: CIST Normal Port4 Configuration - Path Cost Valid values are in the range 0 to 200000000. Setting 0 means Aut…
1.3.6.1.4.1.4756.20.732.20.1.609Columnf2000EASCISTPort4PriorityRemoteBread-writecurrentf2000EAS Series card STP CIST Port Configuration: CIST Normal Port4 Configuration - Priority
1.3.6.1.4.1.4756.20.732.20.1.610Columnf2000EASCISTPort4AdminEdgeRemoteBread-writecurrentf2000EAS Series card STP CIST Port Configuration: CIST Normal Port4 Configuration - STP Enabled 0: Non-edge 1: Edge
1.3.6.1.4.1.4756.20.732.20.1.611Columnf2000EASCISTPort4AutoEdgeRemoteBread-writecurrentf2000EAS Series card STP CIST Port Configuration: CIST Normal Port4 Configuration - Auto Edge 0: Non-edge 1: Edge
1.3.6.1.4.1.4756.20.732.20.1.612Columnf2000EASCISTPort4RestrictedRoleRemoteBread-writecurrentf2000EAS Series card STP CIST Port Configuration: CIST Normal Port4 Configuration - Restricted Role 0: Non-edge 1: Edge
1.3.6.1.4.1.4756.20.732.20.1.613Columnf2000EASCISTPort4RestrictedTCNRemoteBread-writecurrentf2000EAS Series card STP CIST Port Configuration: CIST Normal Port4 Configuration - Restricted TCN 0: Non-edge 1: Edge
1.3.6.1.4.1.4756.20.732.20.1.614Columnf2000EASCISTPort4BPDUGuardRemoteBread-writecurrentf2000EAS Series card STP CIST Port Configuration: CIST Normal Port4 Configuration - BPDU Guard 0: Non-edge 1: Edge
1.3.6.1.4.1.4756.20.732.20.1.615Columnf2000EASCISTPort4PointToPointRemoteBread-writecurrentf2000EAS Series card STP CIST Port Configuration: CIST Normal Port4 Configuration - Point-to-point 0: Forced True 1: Forced False 2: Auto
1.3.6.1.4.1.4756.20.732.20.1.616Columnf2000EASMSTI1AggregatedPathCostRemoteBread-writecurrentf2000EAS Series card MSTI Port Configuration: MSTI1 Aggregated Ports Configuration - Path Cost Valid values are in the range 0 to 200000000. Setting 0 means Au…
1.3.6.1.4.1.4756.20.732.20.1.617Columnf2000EASMSTI1AggregatedPriorityRemoteBread-writecurrentf2000EAS Series card MSTI Port Configuration: MSTI1 Aggregated Ports Configuration - Priority
1.3.6.1.4.1.4756.20.732.20.1.618Columnf2000EASMSTI1Port1PathCostRemoteBread-writecurrentf2000EAS Series card MSTI Port Configuration: MSTI1 Normal Port1 Configuration - Path Cost Valid values are in the range 0 to 200000000. Setting 0 means Auto p…
1.3.6.1.4.1.4756.20.732.20.1.619Columnf2000EASMSTI1Port1PriorityRemoteBread-writecurrentf2000EAS Series card MSTI Port Configuration: MSTI1 Normal Port1 Configuration - Priority
1.3.6.1.4.1.4756.20.732.20.1.620Columnf2000EASMSTI1Port2PathCostRemoteBread-writecurrentf2000EAS Series card MSTI Port Configuration: MSTI1 Normal Port2 Configuration - Path Cost Valid values are in the range 0 to 200000000. Setting 0 means Auto p…
1.3.6.1.4.1.4756.20.732.20.1.621Columnf2000EASMSTI1Port2PriorityRemoteBread-writecurrentf2000EAS Series card MSTI Port Configuration: MSTI1 Normal Port2 Configuration - Priority
1.3.6.1.4.1.4756.20.732.20.1.622Columnf2000EASMSTI1Port3PathCostRemoteBread-writecurrentf2000EAS Series card MSTI Port Configuration: MSTI1 Normal Port3 Configuration - Path Cost Valid values are in the range 0 to 200000000. Setting 0 means Auto p…
1.3.6.1.4.1.4756.20.732.20.1.623Columnf2000EASMSTI1Port3PriorityRemoteBread-writecurrentf2000EAS Series card MSTI Port Configuration: MSTI1 Normal Port3 Configuration - Priority
1.3.6.1.4.1.4756.20.732.20.1.624Columnf2000EASMSTI1Port4PathCostRemoteBread-writecurrentf2000EAS Series card MSTI Port Configuration: MSTI1 Normal Port4 Configuration - Path Cost Valid values are in the range 0 to 200000000. Setting 0 means Auto p…
1.3.6.1.4.1.4756.20.732.20.1.625Columnf2000EASMSTI1Port4PriorityRemoteBread-writecurrentf2000EAS Series card MSTI Port Configuration: MSTI1 Normal Port4 Configuration - Priority
1.3.6.1.4.1.4756.20.732.20.1.626Columnf2000EASMSTI2AggregatedPathCostRemoteBread-writecurrentf2000EAS Series card MSTI Port Configuration: MSTI2 Aggregated Ports Configuration - Path Cost Valid values are in the range 0 to 200000000. Setting 0 means Au…
1.3.6.1.4.1.4756.20.732.20.1.627Columnf2000EASMSTI2AggregatedPriorityRemoteBread-writecurrentf2000EAS Series card MSTI Port Configuration: MSTI2 Aggregated Ports Configuration - Priority
1.3.6.1.4.1.4756.20.732.20.1.628Columnf2000EASMSTI2Port1PathCostRemoteBread-writecurrentf2000EAS Series card MSTI Port Configuration: MSTI2 Normal Port1 Configuration - Path Cost Valid values are in the range 0 to 200000000. Setting 0 means Auto p…
1.3.6.1.4.1.4756.20.732.20.1.629Columnf2000EASMSTI2Port1PriorityRemoteBread-writecurrentf2000EAS Series card MSTI Port Configuration: MSTI2 Normal Port1 Configuration - Priority
1.3.6.1.4.1.4756.20.732.20.1.630Columnf2000EASMSTI2Port2PathCostRemoteBread-writecurrentf2000EAS Series card MSTI Port Configuration: MSTI2 Normal Port2 Configuration - Path Cost Valid values are in the range 0 to 200000000. Setting 0 means Auto p…
1.3.6.1.4.1.4756.20.732.20.1.631Columnf2000EASMSTI2Port2PriorityRemoteBread-writecurrentf2000EAS Series card MSTI Port Configuration: MSTI2 Normal Port2 Configuration - Priority
1.3.6.1.4.1.4756.20.732.20.1.632Columnf2000EASMSTI2Port3PathCostRemoteBread-writecurrentf2000EAS Series card MSTI Port Configuration: MSTI2 Normal Port3 Configuration - Path Cost Valid values are in the range 0 to 200000000. Setting 0 means Auto p…
1.3.6.1.4.1.4756.20.732.20.1.633Columnf2000EASMSTI2Port3PriorityRemoteBread-writecurrentf2000EAS Series card MSTI Port Configuration: MSTI2 Normal Port3 Configuration - Priority
1.3.6.1.4.1.4756.20.732.20.1.634Columnf2000EASMSTI2Port4PathCostRemoteBread-writecurrentf2000EAS Series card MSTI Port Configuration: MSTI2 Normal Port4 Configuration - Path Cost Valid values are in the range 0 to 200000000. Setting 0 means Auto p…
1.3.6.1.4.1.4756.20.732.20.1.635Columnf2000EASMSTI2Port4PriorityRemoteBread-writecurrentf2000EAS Series card MSTI Port Configuration: MSTI2 Normal Port4 Configuration - Priority
1.3.6.1.4.1.4756.20.732.20.1.636Columnf2000EASMSTI3AggregatedPathCostRemoteBread-writecurrentf2000EAS Series card MSTI Port Configuration: MSTI3 Aggregated Ports Configuration - Path Cost Valid values are in the range 0 to 200000000. Setting 0 means Au…
1.3.6.1.4.1.4756.20.732.20.1.637Columnf2000EASMSTI3AggregatedPriorityRemoteBread-writecurrentf2000EAS Series card MSTI Port Configuration: MSTI3 Aggregated Ports Configuration - Priority
1.3.6.1.4.1.4756.20.732.20.1.638Columnf2000EASMSTI3Port1PathCostRemoteBread-writecurrentf2000EAS Series card MSTI Port Configuration: MSTI3 Normal Port1 Configuration - Path Cost Valid values are in the range 0 to 200000000. Setting 0 means Auto p…
1.3.6.1.4.1.4756.20.732.20.1.639Columnf2000EASMSTI3Port1PriorityRemoteBread-writecurrentf2000EAS Series card MSTI Port Configuration: MSTI3 Normal Port1 Configuration - Priority
1.3.6.1.4.1.4756.20.732.20.1.640Columnf2000EASMSTI3Port2PathCostRemoteBread-writecurrentf2000EAS Series card MSTI Port Configuration: MSTI3 Normal Port2 Configuration - Path Cost Valid values are in the range 0 to 200000000. Setting 0 means Auto p…
1.3.6.1.4.1.4756.20.732.20.1.641Columnf2000EASMSTI3Port2PriorityRemoteBread-writecurrentf2000EAS Series card MSTI Port Configuration: MSTI3 Normal Port2 Configuration - Priority
1.3.6.1.4.1.4756.20.732.20.1.642Columnf2000EASMSTI3Port3PathCostRemoteBread-writecurrentf2000EAS Series card MSTI Port Configuration: MSTI1 Normal Port3 Configuration - Path Cost Valid values are in the range 0 to 200000000. Setting 0 means Auto p…
1.3.6.1.4.1.4756.20.732.20.1.643Columnf2000EASMSTI3Port3PriorityRemoteBread-writecurrentf2000EAS Series card MSTI Port Configuration: MSTI3 Normal Port3 Configuration - Priority
1.3.6.1.4.1.4756.20.732.20.1.644Columnf2000EASMSTI3Port4PathCostRemoteBread-writecurrentf2000EAS Series card MSTI Port Configuration: MSTI3 Normal Port4 Configuration - Path Cost Valid values are in the range 0 to 200000000. Setting 0 means Auto p…
1.3.6.1.4.1.4756.20.732.20.1.645Columnf2000EASMSTI3Port4PriorityRemoteBread-writecurrentf2000EAS Series card MSTI Port Configuration: MSTI3 Normal Port4 Configuration - Priority
1.3.6.1.4.1.4756.20.732.20.1.646Columnf2000EASMSTI4AggregatedPathCostRemoteBread-writecurrentf2000EAS Series card MSTI Port Configuration: MSTI4 Aggregated Ports Configuration - Path Cost Valid values are in the range 0 to 200000000. Setting 0 means Au…
1.3.6.1.4.1.4756.20.732.20.1.647Columnf2000EASMSTI4AggregatedPriorityRemoteBread-writecurrentf2000EAS Series card MSTI Port Configuration: MSTI4 Aggregated Ports Configuration - Priority
1.3.6.1.4.1.4756.20.732.20.1.648Columnf2000EASMSTI4Port1PathCostRemoteBread-writecurrentf2000EAS Series card MSTI Port Configuration: MSTI4 Normal Port1 Configuration - Path Cost Valid values are in the range 0 to 200000000. Setting 0 means Auto p…
1.3.6.1.4.1.4756.20.732.20.1.649Columnf2000EASMSTI4Port1PriorityRemoteBread-writecurrentf2000EAS Series card MSTI Port Configuration: MSTI4 Normal Port1 Configuration - Priority
1.3.6.1.4.1.4756.20.732.20.1.650Columnf2000EASMSTI4Port2PathCostRemoteBread-writecurrentf2000EAS Series card MSTI Port Configuration: MSTI4 Normal Port2 Configuration - Path Cost Valid values are in the range 0 to 200000000. Setting 0 means Auto p…
1.3.6.1.4.1.4756.20.732.20.1.651Columnf2000EASMSTI4Port2PriorityRemoteBread-writecurrentf2000EAS Series card MSTI Port Configuration: MSTI4 Normal Port2 Configuration - Priority
1.3.6.1.4.1.4756.20.732.20.1.652Columnf2000EASMSTI4Port3PathCostRemoteBread-writecurrentf2000EAS Series card MSTI Port Configuration: MSTI1 Normal Port3 Configuration - Path Cost Valid values are in the range 0 to 200000000. Setting 0 means Auto p…
1.3.6.1.4.1.4756.20.732.20.1.653Columnf2000EASMSTI4Port3PriorityRemoteBread-writecurrentf2000EAS Series card MSTI Port Configuration: MSTI4 Normal Port3 Configuration - Priority
1.3.6.1.4.1.4756.20.732.20.1.654Columnf2000EASMSTI4Port4PathCostRemoteBread-writecurrentf2000EAS Series card MSTI Port Configuration: MSTI4 Normal Port4 Configuration - Path Cost Valid values are in the range 0 to 200000000. Setting 0 means Auto p…
1.3.6.1.4.1.4756.20.732.20.1.655Columnf2000EASMSTI4Port4PriorityRemoteBread-writecurrentf2000EAS Series card MSTI Port Configuration: MSTI4 Normal Port4 Configuration - Priority
1.3.6.1.4.1.4756.20.732.20.1.656Columnf2000EASMSTI5AggregatedPathCostRemoteBread-writecurrentf2000EAS Series card MSTI Port Configuration: MSTI5 Aggregated Ports Configuration - Path Cost Valid values are in the range 0 to 200000000. Setting 0 means Au…
1.3.6.1.4.1.4756.20.732.20.1.657Columnf2000EASMSTI5AggregatedPriorityRemoteBread-writecurrentf2000EAS Series card MSTI Port Configuration: MSTI5 Aggregated Ports Configuration - Priority
1.3.6.1.4.1.4756.20.732.20.1.658Columnf2000EASMSTI5Port1PathCostRemoteBread-writecurrentf2000EAS Series card MSTI Port Configuration: MSTI5 Normal Port1 Configuration - Path Cost Valid values are in the range 0 to 200000000. Setting 0 means Auto p…
1.3.6.1.4.1.4756.20.732.20.1.659Columnf2000EASMSTI5Port1PriorityRemoteBread-writecurrentf2000EAS Series card MSTI Port Configuration: MSTI5 Normal Port1 Configuration - Priority
1.3.6.1.4.1.4756.20.732.20.1.660Columnf2000EASMSTI5Port2PathCostRemoteBread-writecurrentf2000EAS Series card MSTI Port Configuration: MSTI5 Normal Port2 Configuration - Path Cost Valid values are in the range 0 to 200000000. Setting 0 means Auto p…
1.3.6.1.4.1.4756.20.732.20.1.661Columnf2000EASMSTI5Port2PriorityRemoteBread-writecurrentf2000EAS Series card MSTI Port Configuration: MSTI5 Normal Port2 Configuration - Priority
1.3.6.1.4.1.4756.20.732.20.1.662Columnf2000EASMSTI5Port3PathCostRemoteBread-writecurrentf2000EAS Series card MSTI Port Configuration: MSTI5 Normal Port3 Configuration - Path Cost Valid values are in the range 0 to 200000000. Setting 0 means Auto p…
1.3.6.1.4.1.4756.20.732.20.1.663Columnf2000EASMSTI5Port3PriorityRemoteBread-writecurrentf2000EAS Series card MSTI Port Configuration: MSTI5 Normal Port3 Configuration - Priority
1.3.6.1.4.1.4756.20.732.20.1.664Columnf2000EASMSTI5Port4PathCostRemoteBread-writecurrentf2000EAS Series card MSTI Port Configuration: MSTI5 Normal Port4 Configuration - Path Cost Valid values are in the range 0 to 200000000. Setting 0 means Auto p…
1.3.6.1.4.1.4756.20.732.20.1.665Columnf2000EASMSTI5Port4PriorityRemoteBread-writecurrentf2000EAS Series card MSTI Port Configuration: MSTI5 Normal Port4 Configuration - Priority
1.3.6.1.4.1.4756.20.732.20.1.666Columnf2000EASMSTI6AggregatedPathCostRemoteBread-writecurrentf2000EAS Series card MSTI Port Configuration: MSTI6 Aggregated Ports Configuration - Path Cost Valid values are in the range 0 to 200000000. Setting 0 means Au…
1.3.6.1.4.1.4756.20.732.20.1.667Columnf2000EASMSTI6AggregatedPriorityRemoteBread-writecurrentf2000EAS Series card MSTI Port Configuration: MSTI6 Aggregated Ports Configuration - Priority
1.3.6.1.4.1.4756.20.732.20.1.668Columnf2000EASMSTI6Port1PathCostRemoteBread-writecurrentf2000EAS Series card MSTI Port Configuration: MSTI6 Normal Port1 Configuration - Path Cost Valid values are in the range 0 to 200000000. Setting 0 means Auto p…
1.3.6.1.4.1.4756.20.732.20.1.669Columnf2000EASMSTI6Port1PriorityRemoteBread-writecurrentf2000EAS Series card MSTI Port Configuration: MSTI6 Normal Port1 Configuration - Priority
1.3.6.1.4.1.4756.20.732.20.1.670Columnf2000EASMSTI6Port2PathCostRemoteBread-writecurrentf2000EAS Series card MSTI Port Configuration: MSTI6 Normal Port2 Configuration - Path Cost Valid values are in the range 0 to 200000000. Setting 0 means Auto p…
1.3.6.1.4.1.4756.20.732.20.1.671Columnf2000EASMSTI6Port2PriorityRemoteBread-writecurrentf2000EAS Series card MSTI Port Configuration: MSTI6 Normal Port2 Configuration - Priority
1.3.6.1.4.1.4756.20.732.20.1.672Columnf2000EASMSTI6Port3PathCostRemoteBread-writecurrentf2000EAS Series card MSTI Port Configuration: MSTI6 Normal Port3 Configuration - Path Cost Valid values are in the range 0 to 200000000. Setting 0 means Auto p…
1.3.6.1.4.1.4756.20.732.20.1.673Columnf2000EASMSTI6Port3PriorityRemoteBread-writecurrentf2000EAS Series card MSTI Port Configuration: MSTI6 Normal Port3 Configuration - Priority
1.3.6.1.4.1.4756.20.732.20.1.674Columnf2000EASMSTI6Port4PathCostRemoteBread-writecurrentf2000EAS Series card MSTI Port Configuration: MSTI6 Normal Port4 Configuration - Path Cost Valid values are in the range 0 to 200000000. Setting 0 means Auto p…
1.3.6.1.4.1.4756.20.732.20.1.675Columnf2000EASMSTI6Port4PriorityRemoteBread-writecurrentf2000EAS Series card MSTI Port Configuration: MSTI6 Normal Port4 Configuration - Priority
1.3.6.1.4.1.4756.20.732.20.1.676Columnf2000EASMSTI7AggregatedPathCostRemoteBread-writecurrentf2000EAS Series card MSTI Port Configuration: MSTI7 Aggregated Ports Configuration - Path Cost Valid values are in the range 0 to 200000000. Setting 0 means Au…
1.3.6.1.4.1.4756.20.732.20.1.677Columnf2000EASMSTI7AggregatedPriorityRemoteBread-writecurrentf2000EAS Series card MSTI Port Configuration: MSTI7 Aggregated Ports Configuration - Priority
1.3.6.1.4.1.4756.20.732.20.1.678Columnf2000EASMSTI7Port1PathCostRemoteBread-writecurrentf2000EAS Series card MSTI Port Configuration: MSTI1 Normal Port1 Configuration - Path Cost Valid values are in the range 0 to 200000000. Setting 0 means Auto p…
1.3.6.1.4.1.4756.20.732.20.1.679Columnf2000EASMSTI7Port1PriorityRemoteBread-writecurrentf2000EAS Series card MSTI Port Configuration: MSTI1 Normal Port7 Configuration - Priority
1.3.6.1.4.1.4756.20.732.20.1.680Columnf2000EASMSTI7Port2PathCostRemoteBread-writecurrentf2000EAS Series card MSTI Port Configuration: MSTI7 Normal Port2 Configuration - Path Cost Valid values are in the range 0 to 200000000. Setting 0 means Auto p…
1.3.6.1.4.1.4756.20.732.20.1.681Columnf2000EASMSTI7Port2PriorityRemoteBread-writecurrentf2000EAS Series card MSTI Port Configuration: MSTI7 Normal Port2 Configuration - Priority
1.3.6.1.4.1.4756.20.732.20.1.682Columnf2000EASMSTI7Port3PathCostRemoteBread-writecurrentf2000EAS Series card MSTI Port Configuration: MSTI7 Normal Port3 Configuration - Path Cost Valid values are in the range 0 to 200000000. Setting 0 means Auto p…
1.3.6.1.4.1.4756.20.732.20.1.683Columnf2000EASMSTI7Port3PriorityRemoteBread-writecurrentf2000EAS Series card MSTI Port Configuration: MSTI7 Normal Port3 Configuration - Priority
1.3.6.1.4.1.4756.20.732.20.1.684Columnf2000EASMSTI7Port4PathCostRemoteBread-writecurrentf2000EAS Series card MSTI Port Configuration: MSTI7 Normal Port4 Configuration - Path Cost Valid values are in the range 0 to 200000000. Setting 0 means Auto p…
1.3.6.1.4.1.4756.20.732.20.1.685Columnf2000EASMSTI7Port4PriorityRemoteBread-writecurrentf2000EAS Series card MSTI Port Configuration: MSTI7 Normal Port4 Configuration - Priority
1.3.6.1.4.1.4756.20.732.20.1.686Columnf2000EASCISTBridgeIDRemoteBread-onlycurrentf2000EAS Series card STP Bridges status: CIST - Bridge ID
1.3.6.1.4.1.4756.20.732.20.1.687Columnf2000EASCISTRootIDRemoteBread-onlycurrentf2000EAS Series card STP Bridges status: CIST - Root ID
1.3.6.1.4.1.4756.20.732.20.1.688Columnf2000EASCISTRootPortRemoteBread-onlycurrentf2000EAS Series card STP Bridges status: CIST - Root Port
1.3.6.1.4.1.4756.20.732.20.1.689Columnf2000EASCISTRootCostRemoteBread-onlycurrentf2000EAS Series card STP Bridges status: CIST - Root Cost
1.3.6.1.4.1.4756.20.732.20.1.690Columnf2000EASCISTTopologyFlagRemoteBread-onlycurrentf2000EAS Series card STP Bridges status: CIST - Topology Flag
1.3.6.1.4.1.4756.20.732.20.1.691Columnf2000EASCISTTopologyChangeLastRemoteBread-onlycurrentf2000EAS Series card STP Bridges status: CIST - Topology Change Last
1.3.6.1.4.1.4756.20.732.20.1.692Columnf2000EASMSTI1BridgeIDRemoteBread-onlycurrentf2000EAS Series card STP Bridges status: MSTI1 - Bridge ID
1.3.6.1.4.1.4756.20.732.20.1.693Columnf2000EASMSTI1RootIDRemoteBread-onlycurrentf2000EAS Series card STP Bridges status: MSTI1 - Root ID
1.3.6.1.4.1.4756.20.732.20.1.694Columnf2000EASMSTI1RootPortRemoteBread-onlycurrentf2000EAS Series card STP Bridges status: MSTI1 - Root ID
1.3.6.1.4.1.4756.20.732.20.1.695Columnf2000EASMSTI1RootCostRemoteBread-onlycurrentf2000EAS Series card STP Bridges status: MSTI1 - Root Cost
1.3.6.1.4.1.4756.20.732.20.1.696Columnf2000EASMSTI1TopologyFlagRemoteBread-onlycurrentf2000EAS Series card STP Bridges status: MSTI1 - Topology Flag
1.3.6.1.4.1.4756.20.732.20.1.697Columnf2000EASMSTI1TopologyChangeLastRemoteBread-onlycurrentf2000EAS Series card STP Bridges status: MSTI1 - Topology Change Last
1.3.6.1.4.1.4756.20.732.20.1.698Columnf2000EASMSTI2BridgeIDRemoteBread-onlycurrentf2000EAS Series card STP Bridges status: MSTI2 - Bridge ID
1.3.6.1.4.1.4756.20.732.20.1.699Columnf2000EASMSTI2RootIDRemoteBread-onlycurrentf2000EAS Series card STP Bridges status: MSTI2 - Root ID
1.3.6.1.4.1.4756.20.732.20.1.700Columnf2000EASMSTI2RootPortRemoteBread-onlycurrentf2000EAS Series card STP Bridges status: MSTI2 - Root ID
1.3.6.1.4.1.4756.20.732.20.1.701Columnf2000EASMSTI2RootCostRemoteBread-onlycurrentf2000EAS Series card STP Bridges status: MSTI2 - Root Cost
1.3.6.1.4.1.4756.20.732.20.1.702Columnf2000EASMSTI2TopologyFlagRemoteBread-onlycurrentf2000EAS Series card STP Bridges status: MSTI2 - Topology Flag
1.3.6.1.4.1.4756.20.732.20.1.703Columnf2000EASMSTI2TopologyChangeLastRemoteBread-onlycurrentf2000EAS Series card STP Bridges status: MSTI2 - Topology Change Last
1.3.6.1.4.1.4756.20.732.20.1.704Columnf2000EASMSTI3BridgeIDRemoteBread-onlycurrentf2000EAS Series card STP Bridges status: MSTI3 - Bridge ID
1.3.6.1.4.1.4756.20.732.20.1.705Columnf2000EASMSTI3RootIDRemoteBread-onlycurrentf2000EAS Series card STP Bridges status: MSTI3 - Root ID
1.3.6.1.4.1.4756.20.732.20.1.706Columnf2000EASMSTI3RootPortRemoteBread-onlycurrentf2000EAS Series card STP Bridges status: MSTI3 - Root ID
1.3.6.1.4.1.4756.20.732.20.1.707Columnf2000EASMSTI3RootCostRemoteBread-onlycurrentf2000EAS Series card STP Bridges status: MSTI3 - Root Cost
1.3.6.1.4.1.4756.20.732.20.1.708Columnf2000EASMSTI3TopologyFlagRemoteBread-onlycurrentf2000EAS Series card STP Bridges status: MSTI3 - Topology Flag
1.3.6.1.4.1.4756.20.732.20.1.709Columnf2000EASMSTI3TopologyChangeLastRemoteBread-onlycurrentf2000EAS Series card STP Bridges status: MSTI3 - Topology Change Last
1.3.6.1.4.1.4756.20.732.20.1.710Columnf2000EASMSTI4BridgeIDRemoteBread-onlycurrentf2000EAS Series card STP Bridges status: MSTI4 - Bridge ID
1.3.6.1.4.1.4756.20.732.20.1.711Columnf2000EASMSTI4RootIDRemoteBread-onlycurrentf2000EAS Series card STP Bridges status: MSTI4 - Root ID
1.3.6.1.4.1.4756.20.732.20.1.712Columnf2000EASMSTI4RootPortRemoteBread-onlycurrentf2000EAS Series card STP Bridges status: MSTI4 - Root ID
1.3.6.1.4.1.4756.20.732.20.1.713Columnf2000EASMSTI4RootCostRemoteBread-onlycurrentf2000EAS Series card STP Bridges status: MSTI4 - Root Cost
1.3.6.1.4.1.4756.20.732.20.1.714Columnf2000EASMSTI4TopologyFlagRemoteBread-onlycurrentf2000EAS Series card STP Bridges status: MSTI4 - Topology Flag
1.3.6.1.4.1.4756.20.732.20.1.715Columnf2000EASMSTI4TopologyChangeLastRemoteBread-onlycurrentf2000EAS Series card STP Bridges status: MSTI4 - Topology Change Last
1.3.6.1.4.1.4756.20.732.20.1.716Columnf2000EASMSTI5BridgeIDRemoteBread-onlycurrentf2000EAS Series card STP Bridges status: MSTI5 - Bridge ID
1.3.6.1.4.1.4756.20.732.20.1.717Columnf2000EASMSTI5RootIDRemoteBread-onlycurrentf2000EAS Series card STP Bridges status: MSTI5 - Root ID
1.3.6.1.4.1.4756.20.732.20.1.718Columnf2000EASMSTI5RootPortRemoteBread-onlycurrentf2000EAS Series card STP Bridges status: MSTI5 - Root ID
1.3.6.1.4.1.4756.20.732.20.1.719Columnf2000EASMSTI5RootCostRemoteBread-onlycurrentf2000EAS Series card STP Bridges status: MSTI5 - Root Cost
1.3.6.1.4.1.4756.20.732.20.1.720Columnf2000EASMSTI5TopologyFlagRemoteBread-onlycurrentf2000EAS Series card STP Bridges status: MSTI5 - Topology Flag
1.3.6.1.4.1.4756.20.732.20.1.721Columnf2000EASMSTI5TopologyChangeLastRemoteBread-onlycurrentf2000EAS Series card STP Bridges status: MSTI5 - Topology Change Last
1.3.6.1.4.1.4756.20.732.20.1.722Columnf2000EASMSTI6BridgeIDRemoteBread-onlycurrentf2000EAS Series card STP Bridges status: MSTI6 - Bridge ID
1.3.6.1.4.1.4756.20.732.20.1.723Columnf2000EASMSTI6RootIDRemoteBread-onlycurrentf2000EAS Series card STP Bridges status: MSTI6 - Root ID
1.3.6.1.4.1.4756.20.732.20.1.724Columnf2000EASMSTI6RootPortRemoteBread-onlycurrentf2000EAS Series card STP Bridges status: MSTI6 - Root ID
1.3.6.1.4.1.4756.20.732.20.1.725Columnf2000EASMSTI6RootCostRemoteBread-onlycurrentf2000EAS Series card STP Bridges status: MSTI6 - Root Cost
1.3.6.1.4.1.4756.20.732.20.1.726Columnf2000EASMSTI6TopologyFlagRemoteBread-onlycurrentf2000EAS Series card STP Bridges status: MSTI6 - Topology Flag
1.3.6.1.4.1.4756.20.732.20.1.727Columnf2000EASMSTI6TopologyChangeLastRemoteBread-onlycurrentf2000EAS Series card STP Bridges status: MSTI6 - Topology Change Last
1.3.6.1.4.1.4756.20.732.20.1.728Columnf2000EASMSTI7BridgeIDRemoteBread-onlycurrentf2000EAS Series card STP Bridges status: MSTI7 - Bridge ID
1.3.6.1.4.1.4756.20.732.20.1.729Columnf2000EASMSTI7RootIDRemoteBread-onlycurrentf2000EAS Series card STP Bridges status: MSTI7 - Root ID
1.3.6.1.4.1.4756.20.732.20.1.730Columnf2000EASMSTI7RootPortRemoteBread-onlycurrentf2000EAS Series card STP Bridges status: MSTI7 - Root ID
1.3.6.1.4.1.4756.20.732.20.1.731Columnf2000EASMSTI7RootCostRemoteBread-onlycurrentf2000EAS Series card STP Bridges status: MSTI7 - Root Cost
1.3.6.1.4.1.4756.20.732.20.1.732Columnf2000EASMSTI7TopologyFlagRemoteBread-onlycurrentf2000EAS Series card STP Bridges status: MSTI7 - Topology Flag
1.3.6.1.4.1.4756.20.732.20.1.733Columnf2000EASMSTI7TopologyChangeLastRemoteBread-onlycurrentf2000EAS Series card STP Bridges status: MSTI7 - Topology Change Last
1.3.6.1.4.1.4756.20.732.20.1.734Columnf2000EASSTPPortStatusInst1PortRemoteBread-onlycurrentf2000EAS Series card STP Port status: Instance1 - Port
1.3.6.1.4.1.4756.20.732.20.1.735Columnf2000EASSTPPortStatusInst1CISTRoleRemoteBread-onlycurrentf2000EAS Series card STP Port status: Instance1 - CIST Role
1.3.6.1.4.1.4756.20.732.20.1.736Columnf2000EASSTPPortStatusInst1CISTStateRemoteBread-onlycurrentf2000EAS Series card STP Port status: Instance1 - CIST State
1.3.6.1.4.1.4756.20.732.20.1.737Columnf2000EASSTPPortStatusInst1UptimeRemoteBread-onlycurrentf2000EAS Series card STP Port status: Instance1 -Uptime
1.3.6.1.4.1.4756.20.732.20.1.738Columnf2000EASSTPPortStatusInst2PortRemoteBread-onlycurrentf2000EAS Series card STP Port status: Instance2 - Port
1.3.6.1.4.1.4756.20.732.20.1.739Columnf2000EASSTPPortStatusInst2CISTRoleRemoteBread-onlycurrentf2000EAS Series card STP Port status: Instance2 - CIST Role
1.3.6.1.4.1.4756.20.732.20.1.740Columnf2000EASSTPPortStatusInst2CISTStateRemoteBread-onlycurrentf2000EAS Series card STP Port status: Instance2 - CIST State
1.3.6.1.4.1.4756.20.732.20.1.741Columnf2000EASSTPPortStatusInst2UptimeRemoteBread-onlycurrentf2000EAS Series card STP Port status: Instance2 -Uptime
1.3.6.1.4.1.4756.20.732.20.1.742Columnf2000EASSTPPortStatusInst3PortRemoteBread-onlycurrentf2000EAS Series card STP Port status: Instance3 - Port
1.3.6.1.4.1.4756.20.732.20.1.743Columnf2000EASSTPPortStatusInst3CISTRoleRemoteBread-onlycurrentf2000EAS Series card STP Port status: Instance3 - CIST Role
1.3.6.1.4.1.4756.20.732.20.1.744Columnf2000EASSTPPortStatusInst3CISTStateRemoteBread-onlycurrentf2000EAS Series card STP Port status: Instance3 - CIST State
1.3.6.1.4.1.4756.20.732.20.1.745Columnf2000EASSTPPortStatusInst3UptimeRemoteBread-onlycurrentf2000EAS Series card STP Port status: Instance3 -Uptime
1.3.6.1.4.1.4756.20.732.20.1.746Columnf2000EASSTPPortStatusInst4PortRemoteBread-onlycurrentf2000EAS Series card STP Port status: Instance4 - Port
1.3.6.1.4.1.4756.20.732.20.1.747Columnf2000EASSTPPortStatusInst4CISTRoleRemoteBread-onlycurrentf2000EAS Series card STP Port status: Instance4 - CIST Role
1.3.6.1.4.1.4756.20.732.20.1.748Columnf2000EASSTPPortStatusInst4CISTStateRemoteBread-onlycurrentf2000EAS Series card STP Port status: Instance4 - CIST State
1.3.6.1.4.1.4756.20.732.20.1.749Columnf2000EASSTPPortStatusInst4UptimeRemoteBread-onlycurrentf2000EAS Series card STP Port status: Instance4 -Uptime
1.3.6.1.4.1.4756.20.732.20.1.750Columnf2000EASSTPStatisticsPort1TxMSTPRemoteBread-onlycurrentf2000EAS Series card STP Port Statistics: Port1 -Transmitted MSTP
1.3.6.1.4.1.4756.20.732.20.1.751Columnf2000EASSTPStatisticsPort1TxRSTPRemoteBread-onlycurrentf2000EAS Series card STP Port Statistics: Port1 -Transmitted RSTP
1.3.6.1.4.1.4756.20.732.20.1.752Columnf2000EASSTPStatisticsPort1TxSTPRemoteBread-onlycurrentf2000EAS Series card STP Port Statistics: Port1 -Transmitted RSTP
1.3.6.1.4.1.4756.20.732.20.1.753Columnf2000EASSTPStatisticsPort1TxTCNRemoteBread-onlycurrentf2000EAS Series card STP Port Statistics: Port1 -Transmitted RSTP
1.3.6.1.4.1.4756.20.732.20.1.754Columnf2000EASSTPStatisticsPort1RxMSTPRemoteBread-onlycurrentf2000EAS Series card STP Port Statistics: Port1 -Received MSTP
1.3.6.1.4.1.4756.20.732.20.1.755Columnf2000EASSTPStatisticsPort1RxRSTPRemoteBread-onlycurrentf2000EAS Series card STP Port Statistics: Port1 -Received RSTP
1.3.6.1.4.1.4756.20.732.20.1.756Columnf2000EASSTPStatisticsPort1RxSTPRemoteBread-onlycurrentf2000EAS Series card STP Port Statistics: Port1 -Received RSTP
1.3.6.1.4.1.4756.20.732.20.1.757Columnf2000EASSTPStatisticsPort1RxTCNRemoteBread-onlycurrentf2000EAS Series card STP Port Statistics: Port1 -Received RSTP
1.3.6.1.4.1.4756.20.732.20.1.758Columnf2000EASSTPStatisticsPort1DiscardUnknowRemoteBread-onlycurrentf2000EAS Series card STP Port Statistics: Port1 -Discarded Unknown
1.3.6.1.4.1.4756.20.732.20.1.759Columnf2000EASSTPStatisticsPort1DiscardIllegalRemoteBread-onlycurrentf2000EAS Series card STP Port Statistics: Port1 -Discarded Illegal
1.3.6.1.4.1.4756.20.732.20.1.760Columnf2000EASSTPStatisticsPort2TxMSTPRemoteBread-onlycurrentf2000EAS Series card STP Port Statistics: Port2 -Transmitted MSTP
1.3.6.1.4.1.4756.20.732.20.1.761Columnf2000EASSTPStatisticsPort2TxRSTPRemoteBread-onlycurrentf2000EAS Series card STP Port Statistics: Port2 -Transmitted RSTP
1.3.6.1.4.1.4756.20.732.20.1.762Columnf2000EASSTPStatisticsPort2TxSTPRemoteBread-onlycurrentf2000EAS Series card STP Port Statistics: Port2 -Transmitted RSTP
1.3.6.1.4.1.4756.20.732.20.1.763Columnf2000EASSTPStatisticsPort2TxTCNRemoteBread-onlycurrentf2000EAS Series card STP Port Statistics: Port2 -Transmitted RSTP
1.3.6.1.4.1.4756.20.732.20.1.764Columnf2000EASSTPStatisticsPort2RxMSTPRemoteBread-onlycurrentf2000EAS Series card STP Port Statistics: Port2 -Received MSTP
1.3.6.1.4.1.4756.20.732.20.1.765Columnf2000EASSTPStatisticsPort2RxRSTPRemoteBread-onlycurrentf2000EAS Series card STP Port Statistics: Port1 -Received RSTP
1.3.6.1.4.1.4756.20.732.20.1.766Columnf2000EASSTPStatisticsPort2RxSTPRemoteBread-onlycurrentf2000EAS Series card STP Port Statistics: Port2 -Received RSTP
1.3.6.1.4.1.4756.20.732.20.1.767Columnf2000EASSTPStatisticsPort2RxTCNRemoteBread-onlycurrentf2000EAS Series card STP Port Statistics: Port2 -Received RSTP
1.3.6.1.4.1.4756.20.732.20.1.768Columnf2000EASSTPStatisticsPort2DiscardUnknowRemoteBread-onlycurrentf2000EAS Series card STP Port Statistics: Port2 -Discarded Unknown
1.3.6.1.4.1.4756.20.732.20.1.769Columnf2000EASSTPStatisticsPort2DiscardIllegalRemoteBread-onlycurrentf2000EAS Series card STP Port Statistics: Port2 -Discarded Illegal
1.3.6.1.4.1.4756.20.732.20.1.770Columnf2000EASSTPStatisticsPort3TxMSTPRemoteBread-onlycurrentf2000EAS Series card STP Port Statistics: Port3 -Transmitted MSTP
1.3.6.1.4.1.4756.20.732.20.1.771Columnf2000EASSTPStatisticsPort3TxRSTPRemoteBread-onlycurrentf2000EAS Series card STP Port Statistics: Port3 -Transmitted RSTP
1.3.6.1.4.1.4756.20.732.20.1.772Columnf2000EASSTPStatisticsPort3TxSTPRemoteBread-onlycurrentf2000EAS Series card STP Port Statistics: Port3 -Transmitted RSTP
1.3.6.1.4.1.4756.20.732.20.1.773Columnf2000EASSTPStatisticsPort3TxTCNRemoteBread-onlycurrentf2000EAS Series card STP Port Statistics: Port3 -Transmitted RSTP
1.3.6.1.4.1.4756.20.732.20.1.774Columnf2000EASSTPStatisticsPort3RxMSTPRemoteBread-onlycurrentf2000EAS Series card STP Port Statistics: Port3 -Received MSTP
1.3.6.1.4.1.4756.20.732.20.1.775Columnf2000EASSTPStatisticsPort3RxRSTPRemoteBread-onlycurrentf2000EAS Series card STP Port Statistics: Port3 -Received RSTP
1.3.6.1.4.1.4756.20.732.20.1.776Columnf2000EASSTPStatisticsPort3RxSTPRemoteBread-onlycurrentf2000EAS Series card STP Port Statistics: Port3 -Received RSTP
1.3.6.1.4.1.4756.20.732.20.1.777Columnf2000EASSTPStatisticsPort3RxTCNRemoteBread-onlycurrentf2000EAS Series card STP Port Statistics: Port3 -Received RSTP
1.3.6.1.4.1.4756.20.732.20.1.778Columnf2000EASSTPStatisticsPort3DiscardUnknowRemoteBread-onlycurrentf2000EAS Series card STP Port Statistics: Port3 -Discarded Unknown
1.3.6.1.4.1.4756.20.732.20.1.779Columnf2000EASSTPStatisticsPort3DiscardIllegalRemoteBread-onlycurrentf2000EAS Series card STP Port Statistics: Port3 -Discarded Illegal
1.3.6.1.4.1.4756.20.732.20.1.780Columnf2000EASSTPStatisticsPort4TxMSTPRemoteBread-onlycurrentf2000EAS Series card STP Port Statistics: Port4 -Transmitted MSTP
1.3.6.1.4.1.4756.20.732.20.1.781Columnf2000EASSTPStatisticsPort4TxRSTPRemoteBread-onlycurrentf2000EAS Series card STP Port Statistics: Port4 -Transmitted RSTP
1.3.6.1.4.1.4756.20.732.20.1.782Columnf2000EASSTPStatisticsPort4TxSTPRemoteBread-onlycurrentf2000EAS Series card STP Port Statistics: Port4 -Transmitted RSTP
1.3.6.1.4.1.4756.20.732.20.1.783Columnf2000EASSTPStatisticsPort4TxTCNRemoteBread-onlycurrentf2000EAS Series card STP Port Statistics: Port4 -Transmitted RSTP
1.3.6.1.4.1.4756.20.732.20.1.784Columnf2000EASSTPStatisticsPort4RxMSTPRemoteBread-onlycurrentf2000EAS Series card STP Port Statistics: Port4 -Received MSTP
1.3.6.1.4.1.4756.20.732.20.1.785Columnf2000EASSTPStatisticsPort4RxRSTPRemoteBread-onlycurrentf2000EAS Series card STP Port Statistics: Port4 -Received RSTP
1.3.6.1.4.1.4756.20.732.20.1.786Columnf2000EASSTPStatisticsPort4RxSTPRemoteBread-onlycurrentf2000EAS Series card STP Port Statistics: Port4 -Received RSTP
1.3.6.1.4.1.4756.20.732.20.1.787Columnf2000EASSTPStatisticsPort4RxTCNRemoteBread-onlycurrentf2000EAS Series card STP Port Statistics: Port4 -Received RSTP
1.3.6.1.4.1.4756.20.732.20.1.788Columnf2000EASSTPStatisticsPort4DiscardUnknowRemoteBread-onlycurrentf2000EAS Series card STP Port Statistics: Port4 -Discarded Unknown
1.3.6.1.4.1.4756.20.732.20.1.789Columnf2000EASSTPStatisticsPort4DiscardIllegalRemoteBread-onlycurrentf2000EAS Series card STP Port Statistics: Port4 -Discarded Illegal
1.3.6.1.4.1.4756.20.732.20.1.790Columnf2000EASSTPStatisticsPortClearCounterRemoteBread-writecurrentf2000EAS Series card STP Port Statistics: Clear Counters 0: OFff 1: Action
1.3.6.1.4.1.4756.20.732.20.1.791Columnf2000EASAllowedAccessVLANsRemoteBread-writecurrentf2000EAS Series card Global VLAN Configuration: Allowed Access VLANs By default, only VLAN 1 is enabled. More VLANs may be created by using a list syntax where…
1.3.6.1.4.1.4756.20.732.20.1.792Columnf2000EASVlanEthertypeRemoteBread-writecurrentf2000EAS Series card Global VLAN Configuration: Ethertype for Custom S-ports The format of 'Ethernet Type' is restricted to 0x600-0xFFFF
1.3.6.1.4.1.4756.20.732.20.1.793Columnf2000EASPort1VlanModeRemoteBread-writecurrentf2000EAS Series card Port VLAN Configuration : Port1 - Mode 0: Access 1: Trunk 2: Hybrid
1.3.6.1.4.1.4756.20.732.20.1.794Columnf2000EASPort1VlanIDRemoteBread-writecurrentf2000EAS Series card Port VLAN Configuration : Port1 - VLAN ID
1.3.6.1.4.1.4756.20.732.20.1.795Columnf2000EASPort1VlanTypeRemoteBread-writecurrentf2000EAS Series card Port VLAN Configuration : Port1 - VLAN Type 0: Unaware 1: C-port 2: S-port 3: S-custom-port
1.3.6.1.4.1.4756.20.732.20.1.796Columnf2000EASPort1VlanIngressFilteringRemoteBread-writecurrentf2000EAS Series card Port VLAN Configuration : Port1 - Ingress Filtering 0: Off 1: On
1.3.6.1.4.1.4756.20.732.20.1.797Columnf2000EASPort1VlanIngressAcceptanceRemoteBread-writecurrentf2000EAS Series card Port VLAN Configuration : Port1 - Ingress Acceptance 0: Tagged and untagged 1: Tagged only 2: Untagged only
1.3.6.1.4.1.4756.20.732.20.1.798Columnf2000EASPort1VlanEgressTaggingRemoteBread-writecurrentf2000EAS Series card Port VLAN Configuration : Port1 - Egress Tagging 0: Untag port vlan 1: Tag all 2: Untag all
1.3.6.1.4.1.4756.20.732.20.1.799Columnf2000EASPort1VlanEgressTaggedSpecificallyUntagRemoteBread-writecurrentPorts in Hybrid mode may specify the tagging of frames with VID on egress, which overrules the Egress Tagging setting. Frames classified to these VLANs are tra…
1.3.6.1.4.1.4756.20.732.20.1.800Columnf2000EASPort1VlanEgressTaggedSpecificallyCtagRemoteBread-writecurrentPorts in Hybrid mode may specify the tagging of frames with VID on egress, which overrules the Egress Tagging setting. Frames classified to these VLANs are tra…
1.3.6.1.4.1.4756.20.732.20.1.801Columnf2000EASPort1VlanEgressTaggedSpecificallyStagRemoteBread-writecurrentPorts in Hybrid mode may specify the tagging of frames with VID on egress, which overrules the Egress Tagging setting. Frames classified to these VLANs are tra…
1.3.6.1.4.1.4756.20.732.20.1.802Columnf2000EASPort1VlanEgressTaggedSpecificallySCtagRemoteBread-writecurrentPorts in Hybrid mode may specify the tagging of frames with VID on egress, which overrules the Egress Tagging setting. Frames classified to these VLANs are tra…
1.3.6.1.4.1.4756.20.732.20.1.803Columnf2000EASPort1AllowedVLANSRemoteBread-writecurrentf2000EAS Series card Global VLAN Configuration: Port1 - Allowed VLANs By default, only VLAN 1 is enabled. More VLANs may be created by using a list syntax wher…
1.3.6.1.4.1.4756.20.732.20.1.804Columnf2000EASPort2VlanModeRemoteBread-writecurrentf2000EAS Series card Port VLAN Configuration : Port2 - Mode 0: Access 1: Trunk 2: Hybrid
1.3.6.1.4.1.4756.20.732.20.1.805Columnf2000EASPort2VlanIDRemoteBread-writecurrentf2000EAS Series card Port VLAN Configuration : Port2 - VLAN ID
1.3.6.1.4.1.4756.20.732.20.1.806Columnf2000EASPort2VlanTypeRemoteBread-writecurrentf2000EAS Series card Port VLAN Configuration : Port2 - VLAN Type 0: Unaware 1: C-port 2: S-port 3: S-custom-port
1.3.6.1.4.1.4756.20.732.20.1.807Columnf2000EASPort2VlanIngressFilteringRemoteBread-writecurrentf2000EAS Series card Port VLAN Configuration : Port2 - Ingress Filtering 0: Off 1: On
1.3.6.1.4.1.4756.20.732.20.1.808Columnf2000EASPort2VlanIngressAcceptanceRemoteBread-writecurrentf2000EAS Series card Port VLAN Configuration : Por2 - Ingress Acceptance 0: Tagged and untagged 1: Tagged only 2: Untagged only
1.3.6.1.4.1.4756.20.732.20.1.809Columnf2000EASPort2VlanEgressTaggingRemoteBread-writecurrentf2000EAS Series card Port VLAN Configuration : Port2 - Egress Tagging 0: Untag port vlan 1: Tag all 2: Untag all
1.3.6.1.4.1.4756.20.732.20.1.810Columnf2000EASPort2VlanEgressTaggedSpecificallyUntagRemoteBread-writecurrentPorts in Hybrid mode may specify the tagging of frames with VID on egress, which overrules the Egress Tagging setting. Frames classified to these VLANs are tra…
1.3.6.1.4.1.4756.20.732.20.1.811Columnf2000EASPort2VlanEgressTaggedSpecificallyCtagRemoteBread-writecurrentPorts in Hybrid mode may specify the tagging of frames with VID on egress, which overrules the Egress Tagging setting. Frames classified to these VLANs are tra…
1.3.6.1.4.1.4756.20.732.20.1.812Columnf2000EASPort2VlanEgressTaggedSpecificallyStagRemoteBread-writecurrentPorts in Hybrid mode may specify the tagging of frames with VID on egress, which overrules the Egress Tagging setting. Frames classified to these VLANs are tra…
1.3.6.1.4.1.4756.20.732.20.1.813Columnf2000EASPort2VlanEgressTaggedSpecificallySCtagRemoteBread-writecurrentPorts in Hybrid mode may specify the tagging of frames with VID on egress, which overrules the Egress Tagging setting. Frames classified to these VLANs are tra…
1.3.6.1.4.1.4756.20.732.20.1.814Columnf2000EASPort2AllowedVLANSRemoteBread-writecurrentf2000EAS Series card Global VLAN Configuration: Port2 - Allowed VLANs By default, only VLAN 1 is enabled. More VLANs may be created by using a list syntax wher…
1.3.6.1.4.1.4756.20.732.20.1.815Columnf2000EASPort3VlanModeRemoteBread-writecurrentf2000EAS Series card Port VLAN Configuration : Port3 - Mode 0: Access 1: Trunk 2: Hybrid
1.3.6.1.4.1.4756.20.732.20.1.816Columnf2000EASPort3VlanIDRemoteBread-writecurrentf2000EAS Series card Port VLAN Configuration : Port3 - VLAN ID
1.3.6.1.4.1.4756.20.732.20.1.817Columnf2000EASPort3VlanTypeRemoteBread-writecurrentf2000EAS Series card Port VLAN Configuration : Port3 - VLAN Type 0: Unaware 1: C-port 2: S-port 3: S-custom-port
1.3.6.1.4.1.4756.20.732.20.1.818Columnf2000EASPort3VlanIngressFilteringRemoteBread-writecurrentf2000EAS Series card Port VLAN Configuration : Port3 - Ingress Filtering 0: Off 1: On
1.3.6.1.4.1.4756.20.732.20.1.819Columnf2000EASPort3VlanIngressAcceptanceRemoteBread-writecurrentf2000EAS Series card Port VLAN Configuration : Port3 - Ingress Acceptance 0: Tagged and untagged 1: Tagged only 2: Untagged only
1.3.6.1.4.1.4756.20.732.20.1.820Columnf2000EASPort3VlanEgressTaggingRemoteBread-writecurrentf2000EAS Series card Port VLAN Configuration : Port3 - Egress Tagging 0: Untag port vlan 1: Tag all 2: Untag all
1.3.6.1.4.1.4756.20.732.20.1.821Columnf2000EASPort3VlanEgressTaggedSpecificallyUntagRemoteBread-writecurrentPorts in Hybrid mode may specify the tagging of frames with VID on egress, which overrules the Egress Tagging setting. Frames classified to these VLANs are tra…
1.3.6.1.4.1.4756.20.732.20.1.822Columnf2000EASPort3VlanEgressTaggedSpecificallyCtagRemoteBread-writecurrentPorts in Hybrid mode may specify the tagging of frames with VID on egress, which overrules the Egress Tagging setting. Frames classified to these VLANs are tra…
1.3.6.1.4.1.4756.20.732.20.1.823Columnf2000EASPort3VlanEgressTaggedSpecificallyStagRemoteBread-writecurrentPorts in Hybrid mode may specify the tagging of frames with VID on egress, which overrules the Egress Tagging setting. Frames classified to these VLANs are tra…
1.3.6.1.4.1.4756.20.732.20.1.824Columnf2000EASPort3VlanEgressTaggedSpecificallySCtagRemoteBread-writecurrentPorts in Hybrid mode may specify the tagging of frames with VID on egress, which overrules the Egress Tagging setting. Frames classified to these VLANs are tra…
1.3.6.1.4.1.4756.20.732.20.1.825Columnf2000EASPort3AllowedVLANSRemoteBread-writecurrentf2000EAS Series card Global VLAN Configuration: Port3 - Allowed VLANs By default, only VLAN 1 is enabled. More VLANs may be created by using a list syntax wher…
1.3.6.1.4.1.4756.20.732.20.1.826Columnf2000EASPort4VlanModeRemoteBread-writecurrentf2000EAS Series card Port VLAN Configuration : Port4 - Mode 0: Access 1: Trunk 2: Hybrid
1.3.6.1.4.1.4756.20.732.20.1.827Columnf2000EASPort4VlanIDRemoteBread-writecurrentf2000EAS Series card Port VLAN Configuration : Port4 - VLAN ID
1.3.6.1.4.1.4756.20.732.20.1.828Columnf2000EASPort4VlanTypeRemoteBread-writecurrentf2000EAS Series card Port VLAN Configuration : Port4 - VLAN Type 0: Unaware 1: C-port 2: S-port 3: S-custom-port
1.3.6.1.4.1.4756.20.732.20.1.829Columnf2000EASPort4VlanIngressFilteringRemoteBread-writecurrentf2000EAS Series card Port VLAN Configuration : Port4 - Ingress Filtering 0: Off 1: On
1.3.6.1.4.1.4756.20.732.20.1.830Columnf2000EASPort4VlanIngressAcceptanceRemoteBread-writecurrentf2000EAS Series card Port VLAN Configuration : Port4 - Ingress Acceptance 0: Tagged and untagged 1: Tagged only 2: Untagged only
1.3.6.1.4.1.4756.20.732.20.1.831Columnf2000EASPort4VlanEgressTaggingRemoteBread-writecurrentf2000EAS Series card Port VLAN Configuration : Port4 - Egress Tagging 0: Untag port vlan 1: Tag all 2: Untag all
1.3.6.1.4.1.4756.20.732.20.1.832Columnf2000EASPort4VlanEgressTaggedSpecificallyUntagRemoteBread-writecurrentPorts in Hybrid mode may specify the tagging of frames with VID on egress, which overrules the Egress Tagging setting. Frames classified to these VLANs are tra…
1.3.6.1.4.1.4756.20.732.20.1.833Columnf2000EASPort4VlanEgressTaggedSpecificallyCtagRemoteBread-writecurrentPorts in Hybrid mode may specify the tagging of frames with VID on egress, which overrules the Egress Tagging setting. Frames classified to these VLANs are tra…
1.3.6.1.4.1.4756.20.732.20.1.834Columnf2000EASPort4VlanEgressTaggedSpecificallyStagRemoteBread-writecurrentPorts in Hybrid mode may specify the tagging of frames with VID on egress, which overrules the Egress Tagging setting. Frames classified to these VLANs are tra…
1.3.6.1.4.1.4756.20.732.20.1.835Columnf2000EASPort4VlanEgressTaggedSpecificallySCtagRemoteBread-writecurrentPorts in Hybrid mode may specify the tagging of frames with VID on egress, which overrules the Egress Tagging setting. Frames classified to these VLANs are tra…
1.3.6.1.4.1.4756.20.732.20.1.836Columnf2000EASPort4AllowedVLANSRemoteBread-writecurrentf2000EAS Series card Global VLAN Configuration: Port4 - Allowed VLANs By default, only VLAN 1 is enabled. More VLANs may be created by using a list syntax wher…
1.3.6.1.4.1.4756.20.732.20.1.837Columnf2000EASQOSPort1IngressRemoteBread-writecurrentf2000EAS Series card QOS Port1 Ingress Enabled 0: NO 1: YES
1.3.6.1.4.1.4756.20.732.20.1.838Columnf2000EASQOSPort1IngressRateRemoteBread-writecurrentf2000EAS Series card QOS Port1 Ingress Rate
1.3.6.1.4.1.4756.20.732.20.1.839Columnf2000EASQOSPort1IngressRateUnitRemoteBread-writecurrentf2000EAS Series card QOS Port1 Ingress Rate Unit 0: Kbps 1: Mbps 2: fps 3: kfps
1.3.6.1.4.1.4756.20.732.20.1.840Columnf2000EASQOSPort1IngressBurstSizeRemoteBread-writecurrentf2000EAS Series card QOS Port1 Ingress Burst Size
1.3.6.1.4.1.4756.20.732.20.1.841Columnf2000EASQOSPort2IngressRemoteBread-writecurrentf2000EAS Series card QOS Port2 Ingress Enabled 0: NO 1: YES
1.3.6.1.4.1.4756.20.732.20.1.842Columnf2000EASQOSPort2IngressRateRemoteBread-writecurrentf2000EAS Series card QOS Port2 Ingress Rate
1.3.6.1.4.1.4756.20.732.20.1.843Columnf2000EASQOSPort2IngressRateUnitRemoteBread-writecurrentf2000EAS Series card QOS Port2 Ingress Rate Unit 0: Kbps 1: Mbps 2: fps 3: kfps
1.3.6.1.4.1.4756.20.732.20.1.844Columnf2000EASQOSPort2IngressBurstSizeRemoteBread-writecurrentf2000EAS Series card QOS Port2 Ingress Burst Size
1.3.6.1.4.1.4756.20.732.20.1.845Columnf2000EASQOSPort3IngressRemoteBread-writecurrentf2000EAS Series card QOS Port3 Ingress Enabled 0: NO 1: YES
1.3.6.1.4.1.4756.20.732.20.1.846Columnf2000EASQOSPort3IngressRateRemoteBread-writecurrentf2000EAS Series card QOS Port3 Ingress Rate
1.3.6.1.4.1.4756.20.732.20.1.847Columnf2000EASQOSPort3IngressRateUnitRemoteBread-writecurrentf2000EAS Series card QOS Port3 Ingress Rate Unit 0: Kbps 1: Mbps 2: fps 3: kfps
1.3.6.1.4.1.4756.20.732.20.1.848Columnf2000EASQOSPort3IngressBurstSizeRemoteBread-writecurrentf2000EAS Series card QOS Port3 Ingress Burst Size
1.3.6.1.4.1.4756.20.732.20.1.849Columnf2000EASQOSPort4IngressRemoteBread-writecurrentf2000EAS Series card QOS Port4 Ingress Enabled 0: NO 1: YES
1.3.6.1.4.1.4756.20.732.20.1.850Columnf2000EASQOSPort4IngressRateRemoteBread-writecurrentf2000EAS Series card QOS Port4 Ingress Rate
1.3.6.1.4.1.4756.20.732.20.1.851Columnf2000EASQOSPort4IngressRateUnitRemoteBread-writecurrentf2000EAS Series card QOS Port4 Ingress Rate Unit 0: Kbps 1: Mbps 2: fps 3: kfps
1.3.6.1.4.1.4756.20.732.20.1.852Columnf2000EASQOSPort4IngressBurstSizeRemoteBread-writecurrentf2000EAS Series card QOS Port4 Ingress Burst Size
1.3.6.1.4.1.4756.20.732.20.1.853Columnf2000EASQOSPort1EgressRemoteBread-writecurrentf2000EAS Series card QOS Port1 Egress Enabled 0: NO 1: YES
1.3.6.1.4.1.4756.20.732.20.1.854Columnf2000EASQOSPort1EgressRateRemoteBread-writecurrentf2000EAS Series card QOS Port1 Egress Rate
1.3.6.1.4.1.4756.20.732.20.1.855Columnf2000EASQOSPort1EgressRateUnitRemoteBread-writecurrentf2000EAS Series card QOS Port1 Egress Rate Unit 0: Kbps 1: Mbps
1.3.6.1.4.1.4756.20.732.20.1.856Columnf2000EASQOSPort2EgressRemoteBread-writecurrentf2000EAS Series card QOS Port2 Egress Enabled 0: NO 1: YES
1.3.6.1.4.1.4756.20.732.20.1.857Columnf2000EASQOSPort2EgressRateRemoteBread-writecurrentf2000EAS Series card QOS Port2 Egress Rate
1.3.6.1.4.1.4756.20.732.20.1.858Columnf2000EASQOSPort2EgressRateUnitRemoteBread-writecurrentf2000EAS Series card QOS Port2 Egress Rate Unit 0: Kbps 1: Mbps
1.3.6.1.4.1.4756.20.732.20.1.859Columnf2000EASQOSPort3EgressRemoteBread-writecurrentf2000EAS Series card QOS Port3 Egress Enabled 0: NO 1: YES
1.3.6.1.4.1.4756.20.732.20.1.860Columnf2000EASQOSPort3EgressRateRemoteBread-writecurrentf2000EAS Series card QOS Port3 Egress Rate
1.3.6.1.4.1.4756.20.732.20.1.861Columnf2000EASQOSPort3EgressRateUnitRemoteBread-writecurrentf2000EAS Series card QOS Port3 Egress Rate Unit 0: Kbps 1: Mbps
1.3.6.1.4.1.4756.20.732.20.1.862Columnf2000EASQOSPort4EgressRemoteBread-writecurrentf2000EAS Series card QOS Port4 Egress Enabled 0: NO 1: YES
1.3.6.1.4.1.4756.20.732.20.1.863Columnf2000EASQOSPort4EgressRateRemoteBread-writecurrentf2000EAS Series card QOS Port4 Egress Rate
1.3.6.1.4.1.4756.20.732.20.1.864Columnf2000EASQOSPort4EgressRateUnitRemoteBread-writecurrentf2000EAS Series card QOS Port4 Egress Rate Unit 0: Kbps 1: Mbps
1.3.6.1.4.1.4756.20.732.20.1.865Columnf2000EASQOSUnicastRemoteBread-writecurrentf2000EAS Series card QOS Storm Control Configuration- Unicast 0: NO 1: YES
1.3.6.1.4.1.4756.20.732.20.1.866Columnf2000EASQOSUnicastRateRemoteBread-writecurrentf2000EAS Series card QOS Storm Control Configuration- Unicast Rate
1.3.6.1.4.1.4756.20.732.20.1.867Columnf2000EASQOSUnicastRateUnitRemoteBread-onlycurrentf2000EAS Series card QOS Unicast Rate Unit 2: Fps 3: Kfps
1.3.6.1.4.1.4756.20.732.20.1.868Columnf2000EASQOSMulticastRemoteBread-writecurrentf2000EAS Series card QOS Storm Control Configuration- Multicast 0: NO 1: YES
1.3.6.1.4.1.4756.20.732.20.1.869Columnf2000EASQOSMulticastRateRemoteBread-writecurrentf2000EAS Series card QOS Storm Control Configuration- Multicast Rate
1.3.6.1.4.1.4756.20.732.20.1.870Columnf2000EASQOSMulticastRateUnitRemoteBread-onlycurrentf2000EAS Series card QOS Multicast Rate Unit 2: Fps 3: Kfps
1.3.6.1.4.1.4756.20.732.20.1.871Columnf2000EASQOSBroadcastRemoteBread-writecurrentf2000EAS Series card QOS Storm Control Configuration- Broadcast 0: NO 1: YES
1.3.6.1.4.1.4756.20.732.20.1.872Columnf2000EASQOSBroadcastRateRemoteBread-writecurrentf2000EAS Series card QOS Storm Control Configuration- Broadcast Rate
1.3.6.1.4.1.4756.20.732.20.1.873Columnf2000EASQOSBroadcastRateUnitRemoteBread-onlycurrentf2000EAS Series card QOS Broadcast Rate Unit 2: Fps 3: Kfps
1.3.6.1.4.1.4756.20.732.20.1.874Columnf2000EASPort1LLFLogicRemoteBread-writecurrentf2000EAS Series card Port1 link loss forwarding - Logic 0: AND 1: OR
1.3.6.1.4.1.4756.20.732.20.1.875Columnf2000EASPort1LLFLogicPort2RemoteBread-writecurrentf2000EAS Series card Port1 link loss forwarding - Link/Rx Loss Port2 0: NO 1: YES
1.3.6.1.4.1.4756.20.732.20.1.876Columnf2000EASPort1LLFLogicPort3RemoteBread-writecurrentf2000EAS Series card Port1 link loss forwarding - Link/Rx Loss Port3 0: NO 1: YES
1.3.6.1.4.1.4756.20.732.20.1.877Columnf2000EASPort1LLFLogicPort4RemoteBread-writecurrentf2000EAS Series card Port1 link loss forwarding - Link/Rx Loss Port4 0: NO 1: YES
1.3.6.1.4.1.4756.20.732.20.1.878Columnf2000EASPort2LLFLogicRemoteBread-writecurrentf2000EAS Series card Port2 link loss forwarding - Logic 0: AND 1: OR
1.3.6.1.4.1.4756.20.732.20.1.879Columnf2000EASPort2LLFLogicPort1RemoteBread-writecurrentf2000EAS Series card Port2 link loss forwarding - Link/Rx Loss Port1 0: NO 1: YES
1.3.6.1.4.1.4756.20.732.20.1.880Columnf2000EASPort2LLFLogicPort3RemoteBread-writecurrentf2000EAS Series card Port2 link loss forwarding - Link/Rx Loss Port3 0: NO 1: YES
1.3.6.1.4.1.4756.20.732.20.1.881Columnf2000EASPort2LLFLogicPort4RemoteBread-writecurrentf2000EAS Series card Port2 link loss forwarding - Link/Rx Loss Port4 0: NO 1: YES
1.3.6.1.4.1.4756.20.732.20.1.882Columnf2000EASPort3LLFLogicRemoteBread-writecurrentf2000EAS Series card Port3 link loss forwarding - Logic 0: AND 1: OR
1.3.6.1.4.1.4756.20.732.20.1.883Columnf2000EASPort3LLFLogicPort1RemoteBread-writecurrentf2000EAS Series card Port3 link loss forwarding - Link/Rx Loss Port1 0: NO 1: YES
1.3.6.1.4.1.4756.20.732.20.1.884Columnf2000EASPort3LLFLogicPort2RemoteBread-writecurrentf2000EAS Series card Port3 link loss forwarding - Link/Rx Loss Port2 0: NO 1: YES
1.3.6.1.4.1.4756.20.732.20.1.885Columnf2000EASPort3LLFLogicPort4RemoteBread-writecurrentf2000EAS Series card Port3 link loss forwarding - Link/Rx Loss Port4 0: NO 1: YES
1.3.6.1.4.1.4756.20.732.20.1.886Columnf2000EASPort4LLFLogicRemoteBread-writecurrentf2000EAS Series card Port4 link loss forwarding - Logic 0: AND 1: OR
1.3.6.1.4.1.4756.20.732.20.1.887Columnf2000EASPort4LLFLogicPort1RemoteBread-writecurrentf2000EAS Series card Port4 link loss forwarding - Link/Rx Loss Port1 0: NO 1: YES
1.3.6.1.4.1.4756.20.732.20.1.888Columnf2000EASPort4LLFLogicPort2RemoteBread-writecurrentf2000EAS Series card Port4 link loss forwarding - Link/Rx Loss Port2 0: NO 1: YES
1.3.6.1.4.1.4756.20.732.20.1.889Columnf2000EASPort4LLFLogicPort3RemoteBread-writecurrentf2000EAS Series card Port4 link loss forwarding - Link/Rx Loss Port3 0: NO 1: YES
1.3.6.1.4.1.4756.20.732.20.1.890Columnf2000EASAddIPRouteRemoteBread-writecurrentf2000EAS Series card IP Routes: Add a new IP Routes : Syntax: [<Interface>] [<network>] [<mask_len>] [<gateway>] [<next_hop_vlan>] Interface : 1~4
1.3.6.1.4.1.4756.20.732.20.1.891Columnf2000EASDeleteIPRouteRemoteBread-writecurrentf2000EAS Series card IP Routes num: Delete a IP Routes num: Syntax: [<Interface>] Interface: 1~4
1.3.6.1.4.1.4756.20.732.20.1.892Columnf2000EASPort1RemotePowerStsRemoteBread-onlycurrentf2000EAS Series card Port1 remote Power status 0: None 1: OK 2: Abnormal
1.3.6.1.4.1.4756.20.732.20.1.893Columnf2000EASPort2RemotePowerStsRemoteBread-onlycurrentf2000EAS Series card Port2 remote Power status 0: None 1: OK 2: Abnormal
1.3.6.1.4.1.4756.20.732.20.1.894Columnf2000EASPort3RemotePowerStsRemoteBread-onlycurrentf2000EAS Series card Port3 remote Power status 0: None 1: OK 2: Abnormal
1.3.6.1.4.1.4756.20.732.20.1.895Columnf2000EASPort4RemotePowerStsRemoteBread-onlycurrentf2000EAS Series card Port4 remote Power status 0: None 1: OK 2: Abnormal
1.3.6.1.4.1.4756.20.732.20.1.896Columnf2000EASPort1LinkAlarmRemoteBread-writecurrentf2000EAS Series card Port 1 Link alarm: 0: Disable 1: Enable
1.3.6.1.4.1.4756.20.732.20.1.897Columnf2000EASPort2LinkAlarmRemoteBread-writecurrentf2000EAS Series card Port 2 Link alarm: 0: Disable 1: Enable
1.3.6.1.4.1.4756.20.732.20.1.898Columnf2000EASPort3LinkAlarmRemoteBread-writecurrentf2000EAS Series card Port 3 Link alarm: 0: Disable 1: Enable
1.3.6.1.4.1.4756.20.732.20.1.899Columnf2000EASPort4LinkAlarmRemoteBread-writecurrentf2000EAS Series card Port 4 Link alarm: 0: Disable 1: Enable
1.3.6.1.4.1.4756.20.732.20.1.900Columnf2000EASAcceptRemoteHWResetRemoteBread-writecurrentf2000EAS Series card Accept Remote H/W Reset: 0: Disable 1: Enable
1.3.6.1.4.1.4756.20.732.20.1.901Columnf2000EASRemoteTLPTRemoteBread-writecurrentf2000EAS Series card Remote TLPT: 0: Disable 1: RemoteA 2: RemoteB
1.3.6.1.4.1.4756.20.1000NotificationpowerOFFcurrentPower 1 or 2 is failed or empty.
1.3.6.1.4.1.4756.20.1005NotificationpowerONcurrentPower 1 or 2 is ON.
1.3.6.1.4.1.4756.20.1010NotificationfanOFFcurrentFan 1 or 2 is failed or empty.
1.3.6.1.4.1.4756.20.1015NotificationfanONcurrentFan 1 or 2 is ON.
1.3.6.1.4.1.4756.20.1020NotificationutpLinkDowncurrentAny UTP of line card is down.
1.3.6.1.4.1.4756.20.1025NotificationutpLinkUpcurrentAny UTP of line card is up.
1.3.6.1.4.1.4756.20.1030NotificationfxLinkDowncurrentAny FX of line card is down.
1.3.6.1.4.1.4756.20.1035NotificationfxLinkUpcurrentAny FX of line card is up.
1.3.6.1.4.1.4756.20.1040NotificationfefDetectcurrentAny FEF of line card is detect.
1.3.6.1.4.1.4756.20.1045NotificationfefUndetectcurrentAny FEF of line card is undetect.
1.3.6.1.4.1.4756.20.1050NotificationremotePowerOFFcurrentAny remote power of line card OFF.
1.3.6.1.4.1.4756.20.1055NotificationremotePowerONcurrentAny remote power of line card ON.
1.3.6.1.4.1.4756.20.1060NotificationlineCardUnplugcurrentThe line card of either local or remote unpluged.
1.3.6.1.4.1.4756.20.1065NotificationlineCardPlugcurrentThe line card of either local or remote pluged.
1.3.6.1.4.1.4756.20.1070NotificationalarmModeChgcurrentAlarm mode changed.
1.3.6.1.4.1.4756.20.1080NotificationrestoreParameterscurrentRestore Line Card Parameters.
1.3.6.1.4.1.4756.20.1100NotificationlogincurrentSomebody login.
1.3.6.1.4.1.4756.20.1101NotificationloginErrorcurrentSomebody login error.
1.3.6.1.4.1.4756.20.1105NotificationlogoutcurrentSomebody logout.
1.3.6.1.4.1.4756.20.1110NotificationsiganlLosscurrentSiganl Loss.
1.3.6.1.4.1.4756.20.1115NotificationsiganlNormalcurrentSiganl Normal.
1.3.6.1.4.1.4756.20.1160NotificationrxPowerNormalcurrentRx Power Normal.
1.3.6.1.4.1.4756.20.1161NotificationrxPowerWarningcurrentRx Power Warning.
1.3.6.1.4.1.4756.20.1165NotificationrxPowerAlarmcurrentRx Power Alarm.
1.3.6.1.4.1.4756.20.1170NotificationsfpPlusQsfpPlusUnLockcurrentSfp+ or QSFP+ CDR unLock.
1.3.6.1.4.1.4756.20.1175NotificationsfpPlusQsfpPlusLockcurrentSfp+ or QSFP+ CDR Lock.
1.3.6.1.4.1.4756.20.1180NotificationsfpPlusQsfpPlusTxFaultcurrentSfp+ or QSFP+ Tx Fault.
1.3.6.1.4.1.4756.20.1190NotificationoverTemperaturecurrentover Temperature.
1.3.6.1.4.1.4756.20.1200NotificationfiberPortSyncLosscurrentFiber Port Sync Loss.
1.3.6.1.4.1.4756.20.1205NotificationfiberPortSynccurrentFiber Port Sync.
1.3.6.1.4.1.4756.20.1218NotificationsnmpReconfigcurrentSNMP Reconfig
1.3.6.1.4.1.4756.20.1220Notificatione1PortSyncLosscurrentE1 Port Sync Loss.
1.3.6.1.4.1.4756.20.1225Notificatione1PortSynccurrentE1 Port Sync.
1.3.6.1.4.1.4756.20.1230NotificationsfpPlusQsfpPlusRxFaultcurrentSFP+ or QSFP+ Rx Fault.
1.3.6.1.4.1.4756.20.1240NotificationinputPowerNormalcurrentInput Power Normal.
1.3.6.1.4.1.4756.20.1241NotificationinputPowerWarningcurrentInput Power Low Warning.
1.3.6.1.4.1.4756.20.1242NotificationinputPowerAlarmcurrentInput Power Loss Alarm.
1.3.6.1.4.1.4756.20.1245NotificationoutputPowerNormalcurrentOutput Power Normal.
1.3.6.1.4.1.4756.20.1246NotificationoutputPowerWarningcurrentOutput Power Low Warning.
1.3.6.1.4.1.4756.20.1247NotificationoutputPowerAlarmcurrentOutput Power Fail Alarm.
1.3.6.1.4.1.4756.20.1250NotificationpowerTempHighAbnormalcurrentCase Temperature Abnormal.
1.3.6.1.4.1.4756.20.1251NotificationpowerTempHighNormalcurrentCase Temperature Normal.
1.3.6.1.4.1.4756.20.1252NotificationpowerTempAbnormalcurrentLD Temperature Abnormal.
1.3.6.1.4.1.4756.20.1253NotificationpowerTempNormalcurrentLD Temperature Normal.
1.3.6.1.4.1.4756.20.1254NotificationpowerLDBiasAbnormalcurrentLD Current Abnormal.
1.3.6.1.4.1.4756.20.1255NotificationpowerLDBiasNormalcurrentLD Current Normal.
1.3.6.1.4.1.4756.20.1256NotificationpowerShutdownAbnormalcurrentLD Pump Shutdown.
1.3.6.1.4.1.4756.20.1257NotificationpowerShutdownNormalcurrentLD Pump Normal.
1.3.6.1.4.1.4756.20.1258NotificationpowerDefaultAbnormalcurrentDefault Button Pressed.
1.3.6.1.4.1.4756.20.1260NotificationpowerInputOverAbnormalcurrentInput Power Over Limit Alarm.
1.3.6.1.4.1.4756.20.1261NotificationpowerInputOverNormalcurrentInput Power Normal.
1.3.6.1.4.1.4756.20.1262NotificationpowerOutputOverAbnormalcurrentOutput Power Over Limit Alarm.
1.3.6.1.4.1.4756.20.1263NotificationpowerOutputOverNormalcurrentOutput Power Normal.