CTC-FRM220-MIB
22050 objects
FRM220 NMC MIB FILE V2.57
Imported Objects
| RFC-1215 | TRAP-TYPE |
| SNMPv2-CONF | MODULE-COMPLIANCE NOTIFICATION-GROUP OBJECT-GROUP |
| SNMPv2-SMI | Counter32 enterprises Gauge32 Integer32 IpAddress mib-2 MODULE-IDENTITY NOTIFICATION-TYPE OBJECT-TYPE TimeTicks |
| SNMPv2-TC | AutonomousType DisplayString PhysAddress RowStatus TestAndIncr TEXTUAL-CONVENTION TimeStamp TruthValue |
| OID | Name | Access | Status | Description |
|---|---|---|---|---|
| 1.3.6.1.4.1.4756 | Nodectc | |||
| 1.3.6.1.4.1.4756.20 | Identityfrm220 | read-write | FRM220 NMC MIB FILE V2.57 | |
| 1.3.6.1.4.1.4756.20.1 | ScalarthisChassisID | read-only | current | This chassis ID. |
| 1.3.6.1.4.1.4756.20.2 | ScalarstackIn | read-only | current | Chassis is stacked: 0:No 1:Yes |
| 1.3.6.1.4.1.4756.20.3 | ScalarchassisNo | read-only | current | Number of chassis. |
| 1.3.6.1.4.1.4756.20.4 | ScalarchassisType | read-only | current | What kind of chassis is: 0:CH20 1:CH02 2:CH04 3:CH08 4:CH04A 5:CH02-SMT |
| 1.3.6.1.4.1.4756.20.30 | TablesnmpTable | not-accessible | current | A list of snmp entries. |
| 1.3.6.1.4.1.4756.20.30.1 | RowsnmpEntry | not-accessible | current | An entry containing management information applicable to a particular chassis. |
| 1.3.6.1.4.1.4756.20.30.1.1 | ColumnchassisIndex | read-only | current | A unique value for each chassis. |
| 1.3.6.1.4.1.4756.20.30.1.2 | Columnredundancy | read-write | current | FRM220 Card redundancy mode : 0:Disable 1:Enable |
| 1.3.6.1.4.1.4756.20.30.1.3 | ColumnserialNumber | read-only | current | SNMP card Serial Number |
| 1.3.6.1.4.1.4756.20.30.1.4 | Columnalarm1Mode | read-write | current | Alarm 1 mode: 0:Disable 1:Active if any power fails (default) 2:Active if any user#1 definition is met 3:Force active for manual testing |
| 1.3.6.1.4.1.4756.20.30.1.5 | Columnalarm2Mode | read-write | current | Alarm 2 mode: 0:Disable 1:Active if any fan fails (default) 2:Active if any user#2 definition is met 3:Force active for manual testing |
| 1.3.6.1.4.1.4756.20.30.1.6 | Columnuser1Power1 | read-write | current | User definition #1 for Alarm 1: 0:No defined 1:Alarm 1 is active when power 1 is failure |
| 1.3.6.1.4.1.4756.20.30.1.7 | Columnuser1Power2 | read-write | current | User definition #1 for Alarm 1: 0:No defined 1:Alarm 1 is active when power 2 is failure |
| 1.3.6.1.4.1.4756.20.30.1.8 | Columnuser1Fan1 | read-write | current | User definition #1 for Alarm 1: 0:No defined 1:Alarm 1 is active when fan 1 is failure |
| 1.3.6.1.4.1.4756.20.30.1.9 | Columnuser1Fan2 | read-write | current | User definition #1 for Alarm 1: 0:No defined 1:Alarm 1 is active when fan 2 is failure |
| 1.3.6.1.4.1.4756.20.30.1.10 | Columnuser1UtpLinkDNLocal | read-write | current | User definition #1 for Alarm 1: 0:No defined 1:Alarm 1 is active when Local Utp Link Down is failure |
| 1.3.6.1.4.1.4756.20.30.1.11 | Columnuser1FxLinkDNLocal | read-write | current | User definition #1 for Alarm 1: 0:No defined 1:Alarm 1 is active when Local Fx Link Down is failure |
| 1.3.6.1.4.1.4756.20.30.1.12 | Columnuser1FEFLocal | read-write | current | User definition #1 for Alarm 1: 0:No defined 1:Alarm 1 is active when FEF is failure |
| 1.3.6.1.4.1.4756.20.30.1.13 | Columnuser1RemoPWRABLocal | read-write | current | User definition #1 for Alarm 1: 0:No defined 1:Alarm 1 is active when Remote Power is failure |
| 1.3.6.1.4.1.4756.20.30.1.14 | Columnuser1FxLinkDNRemote | read-write | current | User definition #1 for Alarm 1: 0:No defined 1:Alarm 1 is active when Remote Fx Link Down is failure |
| 1.3.6.1.4.1.4756.20.30.1.15 | Columnuser1UtpLinkDNRemote | read-write | current | User definition #1 for Alarm 1: 0:No defined 1:Alarm 1 is active when Remote Utp Link Down is failure |
| 1.3.6.1.4.1.4756.20.30.1.16 | Columnuser2Power1 | read-write | current | User definition #2 for Alarm 2: 0:No defined 1:Alarm 2 is active when power 1 is failure |
| 1.3.6.1.4.1.4756.20.30.1.17 | Columnuser2Power2 | read-write | current | User definition #2 for Alarm 2: 0:No defined 1:Alarm 2 is active when power 2 is failure |
| 1.3.6.1.4.1.4756.20.30.1.18 | Columnuser2Fan1 | read-write | current | User definition #2 for Alarm 2: 0:No defined 1:Alarm 2 is active when fan 1 is failure |
| 1.3.6.1.4.1.4756.20.30.1.19 | Columnuser2Fan2 | read-write | current | User definition #2 for Alarm 2: 0:No defined 1:Alarm 2 is active when fan 2 is failure |
| 1.3.6.1.4.1.4756.20.30.1.20 | Columnuser2UtpLinkDNLocal | read-write | current | User definition #2 for Alarm 2: 0:No defined 1:Alarm 2 is active when Utp Link Down is failure |
| 1.3.6.1.4.1.4756.20.30.1.21 | Columnuser2FxLinkDNLocal | read-write | current | User definition #2 for Alarm 2: 0:No defined 1:Alarm 2 is active when Fx link Down is failure |
| 1.3.6.1.4.1.4756.20.30.1.22 | Columnuser2FEFLocal | read-write | current | User definition #2 for Alarm 2: 0:No defined 1:Alarm 2 is active when FEF is failure |
| 1.3.6.1.4.1.4756.20.30.1.23 | Columnuser2RemoPWRABLocal | read-write | current | User definition #2 for Alarm 2: 0:No defined 1:Alarm 2 is active when Remote Power is failure |
| 1.3.6.1.4.1.4756.20.30.1.24 | Columnuser2FxLinkDNRemote | read-write | current | User definition #2 for Alarm 2: 0:No defined 1:Alarm 2 is active when Fx Link Down is failure |
| 1.3.6.1.4.1.4756.20.30.1.25 | Columnuser2UtpLinkDNRemote | read-write | current | User definition #2 for Alarm 2: 0:No defined 1:Alarm 2 is active when Utp Link Down is failure |
| 1.3.6.1.4.1.4756.20.30.1.26 | Columnuser1SignalLossLocal | read-write | current | User definition #1 for Alarm 1: 0:No defined 1:Alarm 1 is active when Signal Loss is failure |
| 1.3.6.1.4.1.4756.20.30.1.27 | Columnuser1SignalLossRemote | read-write | current | User definition #1 for Alarm 1: 0:No defined 1:Alarm 1 is active when Signal Loss is failure |
| 1.3.6.1.4.1.4756.20.30.1.28 | Columnuser2SignalLossLocal | read-write | current | User definition #2 for Alarm 2: 0:No defined 1:Alarm 2 is active when Signal Loss is failure |
| 1.3.6.1.4.1.4756.20.30.1.29 | Columnuser2SignalLossRemote | read-write | current | User definition #2 for Alarm 2: 0:No defined 1:Alarm 2 is active when Signal Loss is failure |
| 1.3.6.1.4.1.4756.20.30.1.30 | Columnremotedevicepolling | read-write | current | Remote Device Polling: (for chassis to chassis management) 0:Disable 1:Enable |
| 1.3.6.1.4.1.4756.20.30.1.31 | Columnfan1Type | read-write | current | fan 1 Type: 0:Normal 1:High |
| 1.3.6.1.4.1.4756.20.30.1.32 | Columnfan2Type | read-write | current | fan 2 Type: 0:Normal 1:High |
| 1.3.6.1.4.1.4756.20.30.1.33 | Columnuser1SyncLossLocal | read-write | current | User definition #1 for Alarm 1: 0:No defined 1:Alarm 1 is active when Sync Loss is failure |
| 1.3.6.1.4.1.4756.20.30.1.34 | Columnuser1SyncLossRemote | read-write | current | User definition #1 for Alarm 1: 0:No defined 1:Alarm 1 is active when Sync Loss is failure |
| 1.3.6.1.4.1.4756.20.30.1.35 | Columnuser2SyncLossLocal | read-write | current | User definition #2 for Alarm 2: 0:No defined 1:Alarm 2 is active when Sync Loss is failure |
| 1.3.6.1.4.1.4756.20.30.1.36 | Columnuser2SyncLossRemote | read-write | current | User definition #2 for Alarm 2: 0:No defined 1:Alarm 2 is active when Sync Loss is failure |
| 1.3.6.1.4.1.4756.20.40 | TablechassisCH20Table | not-accessible | current | A list of chassis entries. |
| 1.3.6.1.4.1.4756.20.40.1 | RowchassisCH20Entry | not-accessible | current | An entry containing management information applicable to a particular chassis. |
| 1.3.6.1.4.1.4756.20.40.1.1 | ColumnchassisCH20ID | read-only | current | Chassis ID |
| 1.3.6.1.4.1.4756.20.40.1.2 | ColumnsnmpHWVer | read-only | current | SNMP hardware version x.xx |
| 1.3.6.1.4.1.4756.20.40.1.3 | ColumnsnmpFWVer | read-only | current | SNMP firmware version x.xx |
| 1.3.6.1.4.1.4756.20.40.1.4 | Columnpower1Type | read-only | current | Power 1 type: 0:Empty 1:AC 2:DC48V 3:DC24V |
| 1.3.6.1.4.1.4756.20.40.1.5 | Columnpower1Status | read-only | current | Power 1 status: 0:OK 1:Fail or empty |
| 1.3.6.1.4.1.4756.20.40.1.6 | Columnpower2Type | read-only | current | Power 2 type: 0:Empty 1:AC 2:DC48V 3:DC24V |
| 1.3.6.1.4.1.4756.20.40.1.7 | Columnpower2Status | read-only | current | Power 2 status: 0:OK 1:Fail or empty |
| 1.3.6.1.4.1.4756.20.40.1.8 | Columnfan1RPM | read-only | current | Fan 1 RPM |
| 1.3.6.1.4.1.4756.20.40.1.9 | Columnfan1Status | read-only | current | Fan 1 status: 0:OK 1:Fail |
| 1.3.6.1.4.1.4756.20.40.1.10 | Columnfan2RPM | read-only | current | Fan 2 RPM |
| 1.3.6.1.4.1.4756.20.40.1.11 | Columnfan2Status | read-only | current | Fan 2 status: 0:OK 1:Fail or empty |
| 1.3.6.1.4.1.4756.20.40.1.12 | Columnalarm1Status | read-only | current | Alarm 1 status: 0:Inactive 1:Active |
| 1.3.6.1.4.1.4756.20.40.1.13 | Columnalarm2Status | read-only | current | Alarm 2 status: 0:Inactive 1:Active |
| 1.3.6.1.4.1.4756.20.40.1.14 | ColumntimeServerIP | read-write | current | Time server IP address. |
| 1.3.6.1.4.1.4756.20.40.1.15 | ColumntimeZone | read-write | current | Time zone hh:mm. |
| 1.3.6.1.4.1.4756.20.40.1.16 | ColumnsyncTime | read-write | current | 1:Do synchronise time |
| 1.3.6.1.4.1.4756.20.40.1.17 | ColumnautoRecvTime | read-write | current | 0:Disable auto recieve time at startup 1:Enable auto recieve time at startup |
| 1.3.6.1.4.1.4756.20.40.1.18 | ColumncurDateTime | read-write | current | Set date and time of system |
| 1.3.6.1.4.1.4756.20.41 | NodechassisCH08 | |||
| 1.3.6.1.4.1.4756.20.41.1 | ScalarsnmpHWVerCH08 | read-only | current | SNMP hardware version x.xx |
| 1.3.6.1.4.1.4756.20.41.2 | ScalarsnmpFWVerCH08 | read-only | current | SNMP firmware version x.xx |
| 1.3.6.1.4.1.4756.20.41.3 | Scalarpower1TypeCH08 | read-only | current | Power 1 type: 0:Empty 1:AC 2:DC48V 3:DC24V |
| 1.3.6.1.4.1.4756.20.41.4 | Scalarpower1StatusCH08 | read-only | current | Power 1 status: 0:OK 1:Fail |
| 1.3.6.1.4.1.4756.20.41.5 | Scalarpower2TypeCH08 | read-only | current | Power 2 type: 0:Empty 1:AC 2:DC48V 3:DC24V |
| 1.3.6.1.4.1.4756.20.41.6 | Scalarpower2StatusCH08 | read-only | current | Power 2 status: 0:OK 1:Fail |
| 1.3.6.1.4.1.4756.20.41.7 | Scalarfan1aRPMCH08 | read-only | current | Fan 1a RPM |
| 1.3.6.1.4.1.4756.20.41.8 | Scalarfan1aStatusCH08 | read-only | current | Fan 1a status: 0:OK 1:Fail |
| 1.3.6.1.4.1.4756.20.41.9 | Scalarfan1bRPMCH08 | read-only | current | Fan 1b RPM |
| 1.3.6.1.4.1.4756.20.41.10 | Scalarfan1bStatusCH08 | read-only | current | Fan 1b status: 0:OK 1:Fail |
| 1.3.6.1.4.1.4756.20.41.11 | Scalarfan2aRPMCH08 | read-only | current | Fan 2a RPM |
| 1.3.6.1.4.1.4756.20.41.12 | Scalarfan2aStatusCH08 | read-only | current | Fan 2a status: 0:OK 1:Fail |
| 1.3.6.1.4.1.4756.20.41.13 | Scalarfan2bRPMCH08 | read-only | current | Fan 2b RPM |
| 1.3.6.1.4.1.4756.20.41.14 | Scalarfan2bStatusCH08 | read-only | current | Fan 2b status: 0:OK 1:Fail |
| 1.3.6.1.4.1.4756.20.41.15 | Scalaralarm1StatusCH08 | read-only | current | Alarm 1 status: 0:Inactive 1:Active |
| 1.3.6.1.4.1.4756.20.41.16 | Scalaralarm2StatusCH08 | read-only | current | Alarm 2 status: 0:Inactive 1:Active |
| 1.3.6.1.4.1.4756.20.41.17 | ScalartimeServerIPCH08 | read-write | current | Time server IP address. |
| 1.3.6.1.4.1.4756.20.41.18 | ScalartimeZoneCH08 | read-write | current | Time zone hh:mm. |
| 1.3.6.1.4.1.4756.20.41.19 | ScalarsyncTimeCH08 | read-write | current | 1:Do synchronise time |
| 1.3.6.1.4.1.4756.20.41.20 | ScalarautoRecvTimeCH08 | read-write | current | 0:Disable auto recieve time at startup 1:Enable auto recieve time at startup |
| 1.3.6.1.4.1.4756.20.41.21 | ScalarcurDateTimeCH08 | read-write | current | Set date and time of system |
| 1.3.6.1.4.1.4756.20.42 | NodechassisCH04A | |||
| 1.3.6.1.4.1.4756.20.42.1 | ScalarsnmpHWVerCH04A | read-only | current | SNMP hardware version x.xx |
| 1.3.6.1.4.1.4756.20.42.2 | ScalarsnmpFWVerCH04A | read-only | current | SNMP firmware version x.xx |
| 1.3.6.1.4.1.4756.20.42.3 | Scalarpower1StatusCH04A | read-only | current | Power 1 status: 0:OK 1:Fail |
| 1.3.6.1.4.1.4756.20.42.4 | Scalarpower2StatusCH04A | read-only | current | Power 2 status: 0:OK 1:Fail |
| 1.3.6.1.4.1.4756.20.42.5 | Scalaralarm1StatusCH04A | read-only | current | Alarm 1 status: 0:Inactive 1:Active |
| 1.3.6.1.4.1.4756.20.42.6 | Scalaralarm2StatusCH04A | read-only | current | Alarm 2 status: 0:Inactive 1:Active |
| 1.3.6.1.4.1.4756.20.42.7 | ScalartimeServerIPCH04A | read-write | current | Time server IP address. |
| 1.3.6.1.4.1.4756.20.42.8 | ScalartimeZoneCH04A | read-write | current | Time zone hh:mm. |
| 1.3.6.1.4.1.4756.20.42.9 | ScalarsyncTimeCH04A | read-write | current | 1:Do synchronise time |
| 1.3.6.1.4.1.4756.20.42.10 | ScalarautoRecvTimeCH04A | read-write | current | 0:Disable auto recieve time at startup 1:Enable auto recieve time at startup |
| 1.3.6.1.4.1.4756.20.42.11 | ScalarcurDateTimeCH04A | read-write | current | Set date and time of system |
| 1.3.6.1.4.1.4756.20.43 | NodechassisCH02SMT | |||
| 1.3.6.1.4.1.4756.20.43.1 | ScalarsnmpHWVerCH02SMT | read-only | current | FRM220-CH02-SMT Hardware version x.x. |
| 1.3.6.1.4.1.4756.20.43.2 | ScalarsnmpFWVerCH02SMT | read-only | current | FRM220-CH02-SMT Farmware version x.x. |
| 1.3.6.1.4.1.4756.20.43.3 | Scalarpower1TypeCH02SMT | read-only | current | FRM220-CH02-SMT Power 1 Type. |
| 1.3.6.1.4.1.4756.20.43.4 | Scalarpower2TypeCH02SMT | read-only | current | FRM220-CH02-SMT Power 2 Type. |
| 1.3.6.1.4.1.4756.20.43.5 | Scalarpower1StatusCH02SMT | read-only | current | FRM220-CH02-SMT Power 1 Status. |
| 1.3.6.1.4.1.4756.20.43.6 | Scalarpower2StatusCH02SMT | read-only | current | FRM220-CH02-SMT Power 2 Status. |
| 1.3.6.1.4.1.4756.20.43.7 | Scalarpower1VoltCH02SMT | read-only | current | FRM220-CH02-SMT Power 1 Voltage (V). |
| 1.3.6.1.4.1.4756.20.43.8 | Scalarpower2VoltCH02SMT | read-only | current | FRM220-CH02-SMT Power 2 Voltage (V). |
| 1.3.6.1.4.1.4756.20.43.9 | Scalarpower1CurrCH02SMT | read-only | current | FRM220-CH02-SMT Power 1 Current (A). |
| 1.3.6.1.4.1.4756.20.43.10 | Scalarpower2CurrCH02SMT | read-only | current | FRM220-CH02-SMT Power 2 Current (A). |
| 1.3.6.1.4.1.4756.20.43.11 | Scalarfan1RPMCH02SMT | read-only | current | FRM220-CH02-SMT Fan 1 Revolution Per Minute. |
| 1.3.6.1.4.1.4756.20.43.12 | Scalarfan2RPMCH02SMT | read-only | current | FRM220-CH02-SMT Fan 2 Revolution Per Minute. |
| 1.3.6.1.4.1.4756.20.43.13 | Scalarfan1StatusCH02SMT | read-only | current | FRM220-CH02-SMT Fan 1 Status. |
| 1.3.6.1.4.1.4756.20.43.14 | Scalarfan2StatusCH02SMT | read-only | current | FRM220-CH02-SMT Fan 2 Status. |
| 1.3.6.1.4.1.4756.20.43.15 | Scalaralarm1StatusCH02SMT | read-only | current | Alarm 1 status: 0:Inactive 1:Active |
| 1.3.6.1.4.1.4756.20.43.16 | Scalaralarm2StatusCH02SMT | read-only | current | Alarm 1 status: 0:Inactive 1:Active |
| 1.3.6.1.4.1.4756.20.43.17 | ScalarfanCtrlCH02SMT | read-write | current | Set FRM220-CH02-SMT Fan Control. |
| 1.3.6.1.4.1.4756.20.43.18 | ScalartimeServerIPCH02SMT | read-write | current | Time server IP address. |
| 1.3.6.1.4.1.4756.20.43.19 | ScalartimeZoneCH02SMT | read-write | current | Time zone hh:mm. |
| 1.3.6.1.4.1.4756.20.43.20 | ScalarsyncTimeCH02SMT | read-write | current | 1:Do synchronise time |
| 1.3.6.1.4.1.4756.20.43.21 | ScalarautoRecvTimeCH02SMT | read-write | current | 0:Disable auto recieve time at startup 1:Enable auto recieve time at startup |
| 1.3.6.1.4.1.4756.20.43.22 | ScalarcurDateTimeCH02SMT | read-write | current | Set date and time of system |
| 1.3.6.1.4.1.4756.20.50 | TablelocalSlotTable | not-accessible | current | A list of local slot entries. The number of local slot entries is 20. |
| 1.3.6.1.4.1.4756.20.50.1 | RowlocalSlotEntry | not-accessible | current | An entry containing management information applicable to a particular local slot. |
| 1.3.6.1.4.1.4756.20.50.1.1 | ColumnlocalChassisIndex | read-only | current | A unique value for each local chassis. It starts from 0 to 9 contiguously. |
| 1.3.6.1.4.1.4756.20.50.1.2 | ColumnlocalSlotIndex | read-only | current | A unique value for each local slot. It starts from 1 to 20 contiguously. |
| 1.3.6.1.4.1.4756.20.50.1.3 | ColumnlocalCardType | read-only | current | Local card type: 0:Empty 1:Unknown 2:SNMP 3:FRM200-10/100i 4:FMC-10/100i 5:FRM220-FXO/FXS 6:FRM220-Serial 7:FRM220-Data 8:FRM220-10/100AS-2 9:FRM220-10/100A 10… |
| 1.3.6.1.4.1.4756.20.50.1.4 | ColumnlocalCardName | read-only | current | Local card product name. |
| 1.3.6.1.4.1.4756.20.50.1.5 | ColumnlocalCardSerialNumber | read-only | current | Local card inventory. |
| 1.3.6.1.4.1.4756.20.51 | TableremoteSlotTable | not-accessible | current | A list of remote slot entries. The number of remote slot entries is 20. |
| 1.3.6.1.4.1.4756.20.51.1 | RowremoteSlotEntry | not-accessible | current | An entry containing management information applicable to a particular remote slot. |
| 1.3.6.1.4.1.4756.20.51.1.1 | ColumnremoteChassisIndex | read-only | current | A unique value for each remote chassis. It starts from 0 to 9 contiguously. |
| 1.3.6.1.4.1.4756.20.51.1.2 | ColumnremoteSlotIndex | read-only | current | A unique value for each remote slot. It starts from 1 to 20 contiguously. |
| 1.3.6.1.4.1.4756.20.51.1.3 | ColumnremoteCardType | read-only | current | Remote card type: 0:Empty 1:Unknown 2:SNMP 3:FRM200-10/100I 4:FMC-10/100I 5:FRM220-FXO/FXS 6:FRM220-SERIAL 7:FRM220-DATAPORT 8:FRM220-10/100AS-2 9:FRM220-10/10… |
| 1.3.6.1.4.1.4756.20.51.1.4 | ColumnremoteCardName | read-only | current | Remote card product name. |
| 1.3.6.1.4.1.4756.20.51.1.5 | ColumnremoteCardSerialNumber | read-only | current | Remote card inventory. |
| 1.3.6.1.4.1.4756.20.52 | TableremoteBSlotTable | not-accessible | current | A list of remote B slot entries. The number of remote slot entries is 20. |
| 1.3.6.1.4.1.4756.20.52.1 | RowremoteBSlotEntry | not-accessible | current | An entry containing management information applicable to a particular remote B slot. |
| 1.3.6.1.4.1.4756.20.52.1.1 | ColumnremoteBChassisIndex | read-only | current | A unique value for each remote B chassis. It starts from 0 to 9 contiguously. |
| 1.3.6.1.4.1.4756.20.52.1.2 | ColumnremoteBSlotIndex | read-only | current | A unique value for each remote B slot. It starts from 1 to 20 contiguously. |
| 1.3.6.1.4.1.4756.20.52.1.3 | ColumnremoteBCardType | read-only | current | Remote B card type: 0:Empty 1:Unknown 2:SNMP 3:FRM200-10/100I 4:FMC-10/100I 5:FRM220-FXO/FXS 6:FRM220-SERIAL 7:FRM220-DATAPORT 8:FRM220-10/100AS 9:FRM220-10/10… |
| 1.3.6.1.4.1.4756.20.52.1.4 | ColumnremoteBCardName | read-only | current | Remote B card product name. |
| 1.3.6.1.4.1.4756.20.52.1.5 | ColumnremoteBCardSerialNumber | read-only | current | Remote B card inventory. |
| 1.3.6.1.4.1.4756.20.59 | TableupgradeTable | not-accessible | current | A list of upgrade entries. |
| 1.3.6.1.4.1.4756.20.59.1 | RowupgradeEntry | not-accessible | current | An entry containing management information applicable to a particular upgrade status. |
| 1.3.6.1.4.1.4756.20.59.1.1 | ColumnupgradeChassisIndex | read-only | current | A unique value for each chassis. |
| 1.3.6.1.4.1.4756.20.59.1.2 | ColumntftpServerIP | read-write | current | TFTP server IP address. |
| 1.3.6.1.4.1.4756.20.59.1.3 | ColumnfileSystemFileName | read-write | current | File System File Name The length of Filename is limited to 20 characters. |
| 1.3.6.1.4.1.4756.20.59.1.4 | ColumnflashfileSystem | read-write | current | 1:Do Flash NMC File System |
| 1.3.6.1.4.1.4756.20.59.1.5 | ColumnupgradeLineCardType | read-write | current | Upgrade Line Card - Card Type: 0:None 1:FRM220-10/100i 2:FRM220-1000EAS-X-1 3:FRM220A-1000EAS-X 4:FRM220-1000EAS-X-2F 5:FRM220-100AS-1 6:FRM220-FOM01 7:FRM220-… |
| 1.3.6.1.4.1.4756.20.59.1.6 | ColumnupgradeLineCardSlot | read-write | current | Upgrade Line Card - Slot: 0:All 2:Slot 2 3:Slot 3 4:Slot 4 5:Slot 5 6:Slot 6 7:Slot 7 8:Slot 8 9:Slot 9 10:Slot 10 11:Slot 11 12:Slot 12 13:Slot 13 14:Slot 14 … |
| 1.3.6.1.4.1.4756.20.59.1.7 | ColumnupgradeLineCardSide | read-write | current | Upgrade Line Card - Side 0:Local 1:Remote (A) 2:Remote B |
| 1.3.6.1.4.1.4756.20.59.1.8 | ColumnupgradeLineCardFileName | read-write | current | Upgrade Line Card - File Name The length of Filename is limited to 20 characters. |
| 1.3.6.1.4.1.4756.20.59.1.9 | ColumnupgradeLineCard | read-write | current | 1:Do Upgrade Line Card For upgrading local side 1000EAS/X,1000EAS/X-1,1000EAS/X-2F,100AS-1 F/W: During this processing, the other NIC card types will NOT be mo… |
| 1.3.6.1.4.1.4756.20.59.1.10 | ColumnupgradeStatus | read-only | current | Upgrade status |
| 1.3.6.1.4.1.4756.20.60 | Nodef100ILocalCards | |||
| 1.3.6.1.4.1.4756.20.60.20 | Tablef100ILocalTable | not-accessible | current | A list of local FRM220-10/100I card entries. The number of entries is f100I-No-L. |
| 1.3.6.1.4.1.4756.20.60.20.1 | Rowf100ILocalEntry | not-accessible | current | An entry containing management information applicable to a particular local FRM220-10/100I card. |
| 1.3.6.1.4.1.4756.20.60.20.1.1 | Columnf100IChassisIndexLocal | read-only | current | A unique value for each local card. It is the chassis location number. |
| 1.3.6.1.4.1.4756.20.60.20.1.2 | Columnf100ISlotIndexLocal | read-only | current | A unique value for each local card. It is the slot location number. |
| 1.3.6.1.4.1.4756.20.60.20.1.3 | Columnf100ICardHWVerLocal | read-only | current | Local FRM220-10/100I card hardware version x.xxx |
| 1.3.6.1.4.1.4756.20.60.20.1.4 | Columnf100ICardFWVerLocal | read-only | current | Local FRM220-10/100I card firmware version x.xxx |
| 1.3.6.1.4.1.4756.20.60.20.1.5 | Columnf100ICardCPLDVerLocal | read-only | current | Local FRM220-10/100I card CPLD version x.xxx |
| 1.3.6.1.4.1.4756.20.60.20.1.6 | Columnf100ICardFPGAVerLocal | read-only | current | Local FRM220-10/100I card FPGA version x.xxx |
| 1.3.6.1.4.1.4756.20.60.20.1.7 | Columnf100IPortActiveLocal | read-write | current | Local FRM220-10/100I card active: 0:Inactive 1:Active |
| 1.3.6.1.4.1.4756.20.60.20.1.8 | Columnf100IInBandManagLocal | read-write | current | Local FRM220-10/100I card manages remote: 0:Disable 1:Enable |
| 1.3.6.1.4.1.4756.20.60.20.1.9 | Columnf100IUtpLinkLocal | read-only | current | Local FRM220-10/100I card UTP link status: 0:Down 1:Up |
| 1.3.6.1.4.1.4756.20.60.20.1.10 | Columnf100IUtpRxActLocal | read-only | current | Local FRM220-10/100I card UTP receive active status: 0:Off 1:On |
| 1.3.6.1.4.1.4756.20.60.20.1.11 | Columnf100IUtpNegoLocal | read-write | current | Local FRM220-10/100I card UTP negotiation status: 0:Manual 1:Auto |
| 1.3.6.1.4.1.4756.20.60.20.1.12 | Columnf100IUtpSpeedLocal | read-write | current | Local FRM220-10/100I card UTP speed: 0:10MHz 1:100MHz |
| 1.3.6.1.4.1.4756.20.60.20.1.13 | Columnf100IUtpDuplexLocal | read-write | current | Local FRM220-10/100I card UTP duplex: 0:Half duplex mode 1:Full duplex mode |
| 1.3.6.1.4.1.4756.20.60.20.1.14 | Columnf100IUtpSpeedStatusLocal | read-only | current | Local FRM220-10/100I card UTP speed status: 0:10MHz 1:100MHz |
| 1.3.6.1.4.1.4756.20.60.20.1.15 | Columnf100IUtpDuplexStatusLocal | read-only | current | Local FRM220-10/100I card UTP duplex status: 0:Half duplex mode 1:Full duplex mode |
| 1.3.6.1.4.1.4756.20.60.20.1.16 | Columnf100IUtpRxByteLocal | read-only | current | Local FRM220-10/100I card UTP-in octet counter |
| 1.3.6.1.4.1.4756.20.60.20.1.17 | Columnf100IUtpTxByteLocal | read-only | current | Local FRM220-10/100I card UTP-out octet counter |
| 1.3.6.1.4.1.4756.20.60.20.1.18 | Columnf100IUtpFnlRxByteLocal | read-only | current | Local FRM220-10/100I card UTP-in final octets |
| 1.3.6.1.4.1.4756.20.60.20.1.19 | Columnf100IUtpFnlTxByteLocal | read-only | current | Local FRM220-10/100I card UTP-out final octets |
| 1.3.6.1.4.1.4756.20.60.20.1.20 | Columnf100IFxLinkLocal | read-only | current | Local FRM220-10/100I card fiber link status: 0:Down 1:Up |
| 1.3.6.1.4.1.4756.20.60.20.1.21 | Columnf100IFxRxActLocal | read-only | current | Local FRM220-10/100I card fiber receiver active status: 0:Off 1:On |
| 1.3.6.1.4.1.4756.20.60.20.1.22 | Columnf100IFxFEFLocal | read-only | current | Local FRM220-10/100I card fiber detected Far End Fault: 0:Off 1:Detected |
| 1.3.6.1.4.1.4756.20.60.20.1.23 | Columnf100IFxLBTestLocal | read-write | current | Force remote FRM220-10/100I card to do fiber LoopBack testing: 0:Off 1:Action |
| 1.3.6.1.4.1.4756.20.60.20.1.24 | Columnf100IFxLBStatusLocal | read-only | current | Local FRM220-10/100I card fiber LoopBack testing status: 0:Off 1:Ok 2:Fail |
| 1.3.6.1.4.1.4756.20.60.20.1.25 | Columnf100IFxRemoPWRAbLocal | read-only | current | Local FRM220-10/100I card fiber Remote Power status: 0:Abnormal 1:OK |
| 1.3.6.1.4.1.4756.20.60.20.1.26 | Columnf100IIrlModeLocal | read-write | current | Local FRM220-10/100I card Ingress Rate Limit mode: 0:No limit 1:n x 32K 2:n x 512K |
| 1.3.6.1.4.1.4756.20.60.20.1.27 | Columnf100IIrlMultLocal | read-write | current | Local FRM220-10/100I card Ingress Rate Limit multiple: When the irlMode-L is n x 32K mode, the irlMult-L should be the value between 0 to 255; When the irlMode… |
| 1.3.6.1.4.1.4756.20.60.20.1.28 | Columnf100IErlModeLocal | read-write | current | Local FRM220-10/100I card Egress Rate Limit mode: 0:No limit 1:n x 32K 2:n x 512K |
| 1.3.6.1.4.1.4756.20.60.20.1.29 | Columnf100IErlMultLocal | read-write | current | Local FRM220-10/100I card Egress Rate Limit multiple: When the erlMode-L is n x 32K mode, the erlMult-L should be the value between 0 to 255; When the erlMode-… |
| 1.3.6.1.4.1.4756.20.60.20.1.30 | Columnf100IFxRxByteLocal | read-only | current | Local FRM220-10/100I card FX-in octet counter |
| 1.3.6.1.4.1.4756.20.60.20.1.31 | Columnf100IFxTxByteLocal | read-only | current | Local FRM220-10/100I card FX-out octet counter |
| 1.3.6.1.4.1.4756.20.60.20.1.32 | Columnf100IFxFnlRxByteLocal | read-only | current | Local FRM220-10/100I card FX-in final octets |
| 1.3.6.1.4.1.4756.20.60.20.1.33 | Columnf100IFxFnlTxByteLocal | read-only | current | Local FRM220-10/100I card FX-out final octets |
| 1.3.6.1.4.1.4756.20.60.20.1.34 | Columnf100IPortResetLocal | read-write | current | Force local FRM220-10/100I card to reset mode: 0:Off 1:Action |
| 1.3.6.1.4.1.4756.20.60.20.1.35 | Columnf100IClrCountersLocal | read-write | current | Force local FRM220-10/100I card to clear all counters: 0:Off 1:Action |
| 1.3.6.1.4.1.4756.20.60.20.1.36 | Columnf100IOpModeLocal | read-write | current | Local FRM220-10/100I card operation mode: 0:Switch mode 1:Converter mode |
| 1.3.6.1.4.1.4756.20.60.20.1.37 | Columnf100ILfpModeLocal | read-write | current | Local FRM220-10/100I card Link Fault Pass-through mode: 0:Disable 1:Enable |
| 1.3.6.1.4.1.4756.20.60.20.1.38 | Columnf100IAlsModeLocal | read-write | current | Local FRM220-10/100I card Auto Laser Shutdown mode: 0:Disable 1:Enable |
| 1.3.6.1.4.1.4756.20.60.20.1.39 | Columnf100ISendFHRLocal | read-write | current | Local FRM220-10/100I card send Fiber Hardware Reset to remote: 0:No action 1:Action |
| 1.3.6.1.4.1.4756.20.60.20.1.40 | Columnf100ISettoDefaultLocal | read-write | current | Local FRM220-10/100I card Set to default: 0:No action 1:Action |
| 1.3.6.1.4.1.4756.20.60.20.1.41 | Columnf100IFxDDLocal | read-only | current | Local FRM220-10/100I card fiber Digital Diagnostic function: 0:No 1:Yes |
| 1.3.6.1.4.1.4756.20.60.20.1.42 | Columnf100IDDVendorLocal | read-only | current | Local FRM220-10/100I card fiber D/D information: Vendor name |
| 1.3.6.1.4.1.4756.20.60.20.1.43 | Columnf100IDDPartNoLocal | read-only | current | Local FRM220-10/100I card fiber D/D information: Vendor part number |
| 1.3.6.1.4.1.4756.20.60.20.1.44 | Columnf100IDDFiberTypeLocal | read-only | current | Local FRM220-10/100I card fiber D/D information: Fiber Type |
| 1.3.6.1.4.1.4756.20.60.20.1.45 | Columnf100IDDWaveLenLocal | read-only | current | Local FRM220-10/100I card fiber D/D information: Wave length |
| 1.3.6.1.4.1.4756.20.60.20.1.46 | Columnf100IDDWaveLen2Local | read-only | current | Local FRM220-10/100I card fiber D/D information: Wave length 2 |
| 1.3.6.1.4.1.4756.20.60.20.1.47 | Columnf100IDDLinkLenLocal | read-only | current | Local FRM220-10/100I card fiber D/D information: Link length |
| 1.3.6.1.4.1.4756.20.60.20.1.48 | Columnf100IDDLenUnitLocal | read-only | current | Local FRM220-10/100I card fiber D/D information: Length Unit |
| 1.3.6.1.4.1.4756.20.60.20.1.49 | Columnf100IDDStatusLocal | read-only | current | Local FRM220-10/100I card fiber D/D information: Status Support |
| 1.3.6.1.4.1.4756.20.60.20.1.50 | Columnf100IDDRxSensLocal | read-only | current | Local FRM220-10/100I card fiber D/D information: Rx Sensitivity |
| 1.3.6.1.4.1.4756.20.60.20.1.51 | Columnf100IDDTxPWRLocal | read-only | current | Local FRM220-10/100I card fiber D/D information: Tx power |
| 1.3.6.1.4.1.4756.20.60.20.1.52 | Columnf100IDDRxPWRLocal | read-only | current | Local FRM220-10/100I card fiber D/D information: Rx power |
| 1.3.6.1.4.1.4756.20.60.20.1.53 | Columnf100IDDTempLocal | read-only | current | Local FRM220-10/100I card fiber D/D information: Temperature in degree C |
| 1.3.6.1.4.1.4756.20.60.20.1.54 | Columnf100IDDPWRMarginLocal | read-only | current | Local FRM220-10/100I card fiber D/D information: Power margin |
| 1.3.6.1.4.1.4756.20.60.20.1.55 | Columnf100IDDPWRLossLocal | read-only | current | Local FRM220-10/100I card fiber D/D information: Power loss |
| 1.3.6.1.4.1.4756.20.60.20.1.56 | Columnf100IInfoR1SN1Local | read-only | current | Local FRM220-10/100I card INFORemoteOM S/N 1 information |
| 1.3.6.1.4.1.4756.20.60.20.1.57 | Columnf100IInfoR1SN2Local | read-only | current | Local FRM220-10/100I card INFORemoteOM S/N 2 information |
| 1.3.6.1.4.1.4756.20.61 | Nodef100IRemoteCards | |||
| 1.3.6.1.4.1.4756.20.61.20 | Tablef100IRemoteTable | not-accessible | current | A list of remote FRM220-10/100I card entries. The number of entries is f100I-NoRemote. |
| 1.3.6.1.4.1.4756.20.61.20.1 | Rowf100IRemoteEntry | not-accessible | current | An entry containing management information applicable to a particular remote FRM220-10/100I card. |
| 1.3.6.1.4.1.4756.20.61.20.1.1 | Columnf100IChassisIndexRemote | read-only | current | A unique value for each local card. It is the chassis location number. |
| 1.3.6.1.4.1.4756.20.61.20.1.2 | Columnf100ISlotIndexRemote | read-only | current | A unique value for each remote card. It is the slot location number. |
| 1.3.6.1.4.1.4756.20.61.20.1.3 | Columnf100ICardHWVerRemote | read-only | current | Remote FRM220-10/100I card hardware version x.xxx |
| 1.3.6.1.4.1.4756.20.61.20.1.4 | Columnf100ICardFWVerRemote | read-only | current | Remote FRM220-10/100I card firmware version x.xxx |
| 1.3.6.1.4.1.4756.20.61.20.1.5 | Columnf100ICardCPLDVerRemote | read-only | current | Remote FRM220-10/100I card CPLD version x.xxx |
| 1.3.6.1.4.1.4756.20.61.20.1.6 | Columnf100ICardFPGAVerRemote | read-only | current | Remote FRM220-10/100I card FPGA version x.xxx |
| 1.3.6.1.4.1.4756.20.61.20.1.7 | Columnf100IPortActiveRemote | read-only | current | Remote FRM220-10/100I card active: (It is read-only in remote side.) 0:Inactive 1:Active |
| 1.3.6.1.4.1.4756.20.61.20.1.8 | Columnf100IInBandManagRemote | read-only | current | (Local only) FRM220-10/100I card manages remote: 0:Disable 1:Enable |
| 1.3.6.1.4.1.4756.20.61.20.1.9 | Columnf100IUtpLinkRemote | read-only | current | Remote FRM220-10/100I card UTP link status: 0:Down 1:Up |
| 1.3.6.1.4.1.4756.20.61.20.1.10 | Columnf100IUtpRxActRemote | read-only | current | Remote FRM220-10/100I card UTP receive active status: 0:Off 1:On |
| 1.3.6.1.4.1.4756.20.61.20.1.11 | Columnf100IUtpNegoRemote | read-write | current | Remote FRM220-10/100I card UTP negotiation status: 0:Manual 1:Auto |
| 1.3.6.1.4.1.4756.20.61.20.1.12 | Columnf100IUtpSpeedRemote | read-write | current | Remote FRM220-10/100I card UTP speed: 0:10MHz 1:100MHz |
| 1.3.6.1.4.1.4756.20.61.20.1.13 | Columnf100IUtpDuplexRemote | read-write | current | Remote FRM220-10/100I card UTP duplex: 0:Half duplex mode 1:Full duplex mode |
| 1.3.6.1.4.1.4756.20.61.20.1.14 | Columnf100IUtpSpeedStatusRemote | read-only | current | Remote FRM220-10/100I card UTP speed status: 0:10MHz 1:100MHz |
| 1.3.6.1.4.1.4756.20.61.20.1.15 | Columnf100IUtpDuplexStatusRemote | read-only | current | Remote FRM220-10/100I card UTP duplex status: 0:Half duplex mode 1:Full duplex mode |
| 1.3.6.1.4.1.4756.20.61.20.1.16 | Columnf100IUtpRxByteRemote | read-only | current | Remote FRM220-10/100I card UTP-in octet counter |
| 1.3.6.1.4.1.4756.20.61.20.1.17 | Columnf100IUtpTxByteRemote | read-only | current | Remote FRM220-10/100I card UTP-out octet counter |
| 1.3.6.1.4.1.4756.20.61.20.1.18 | Columnf100IUtpFnlRxByteRemote | read-only | current | Remote FRM220-10/100I card UTP-in final octets |
| 1.3.6.1.4.1.4756.20.61.20.1.19 | Columnf100IUtpFnlTxByteRemote | read-only | current | Remote FRM220-10/100I card UTP-out final octets |
| 1.3.6.1.4.1.4756.20.61.20.1.20 | Columnf100IFxLinkRemote | read-only | current | Remote FRM220-10/100I card fiber link status: 0:Down 1:Up |
| 1.3.6.1.4.1.4756.20.61.20.1.21 | Columnf100IFxRxActRemote | read-only | current | Remote FRM220-10/100I card fiber receiver active status: 0:Off 1:On |
| 1.3.6.1.4.1.4756.20.61.20.1.22 | Columnf100IFxFEFRemote | read-only | current | Remote FRM220-10/100I card fiber detected Far End Fault: 0:Off 1:Detected |
| 1.3.6.1.4.1.4756.20.61.20.1.23 | Columnf100IFxLBTestRemote | read-write | current | Force local FRM220-10/100I card to do fiber LoopBack testing: 0:Off 1:Action |
| 1.3.6.1.4.1.4756.20.61.20.1.24 | Columnf100IFxLBStatusRemote | read-only | current | Remote FRM220-10/100I card fiber LoopBack testing status: 0:Off 1:Ok 2:Fail |
| 1.3.6.1.4.1.4756.20.61.20.1.25 | Columnf100IFxRemoPWRAbRemote | read-only | current | Remote FRM220-10/100I card fiber Remote Power status: 0:Abnormal 1:OK |
| 1.3.6.1.4.1.4756.20.61.20.1.26 | Columnf100IIrlModeRemote | read-write | current | Remote FRM220-10/100I card Ingress Rate Limit mode: 0:No limit 1:n x 32K 2:n x 512K |
| 1.3.6.1.4.1.4756.20.61.20.1.27 | Columnf100IIrlMultRemote | read-write | current | Remote FRM220-10/100I card Ingress Rate Limit multiple: When the irlModeRemote is n x 32K mode, the irlMultRemote should be the value between 0 to 255; When th… |
| 1.3.6.1.4.1.4756.20.61.20.1.28 | Columnf100IErlModeRemote | read-write | current | Remote FRM220-10/100I card Egress Rate Limit mode: 0:No limit 1:n x 32K 2:n x 512K |
| 1.3.6.1.4.1.4756.20.61.20.1.29 | Columnf100IErlMultRemote | read-write | current | Remote FRM220-10/100I card Egress Rate Limit multiple: When the erlModeRemote is n x 32K mode, the erlMultRemote should be the value between 0 to 255; When the… |
| 1.3.6.1.4.1.4756.20.61.20.1.30 | Columnf100IFxRxByteRemote | read-only | current | Remote FRM220-10/100I card FX-in octet counter |
| 1.3.6.1.4.1.4756.20.61.20.1.31 | Columnf100IFxTxByteRemote | read-only | current | Remote FRM220-10/100I card FX-out octet counter |
| 1.3.6.1.4.1.4756.20.61.20.1.32 | Columnf100IFxFnlRxByteRemote | read-only | current | Remote FRM220-10/100I card FX-in final octets |
| 1.3.6.1.4.1.4756.20.61.20.1.33 | Columnf100IFxFnlTxByteRemote | read-only | current | Remote FRM220-10/100I card FX-out final octets |
| 1.3.6.1.4.1.4756.20.61.20.1.34 | Columnf100IPortResetRemote | read-write | current | Force remote FRM220-10/100I card to reset mode: 0:Off 1:Action |
| 1.3.6.1.4.1.4756.20.61.20.1.35 | Columnf100IClrCountersRemote | read-write | current | Force remote FRM220-10/100I card to clear all counters: 0:Off 1:Action |
| 1.3.6.1.4.1.4756.20.61.20.1.36 | Columnf100IOpModeRemote | read-write | current | Remote FRM220-10/100I card operation mode: 0:Switch mode 1:Converter mode |
| 1.3.6.1.4.1.4756.20.61.20.1.37 | Columnf100ILfpModeRemote | read-write | current | Remote FRM220-10/100I card Link Fault Pass-through mode: 0:Disable 1:Enable |
| 1.3.6.1.4.1.4756.20.61.20.1.38 | Columnf100IAlsModeRemote | read-write | current | Remote FRM220-10/100I card Auto Laser Shutdown mode: 0:Disable 1:Enable |
| 1.3.6.1.4.1.4756.20.61.20.1.39 | Columnf100IFhrModeRemote | read-write | current | Remote FRM220-10/100I card accepts Fiber Hardware Reset mode: 0:Disable 1:Enable |
| 1.3.6.1.4.1.4756.20.61.20.1.40 | Columnf100ISettoDefaultRemote | read-write | current | Remote FRM220-10/100I card Set to default: 0:Disable 1:Enable |
| 1.3.6.1.4.1.4756.20.61.20.1.41 | Columnf100IFxDDRemote | read-only | current | Remote FRM220-10/100I card fiber Digital Diagnostic function: 0:No 1:Yes |
| 1.3.6.1.4.1.4756.20.61.20.1.42 | Columnf100IDDVendorRemote | read-only | current | Remote FRM220-10/100I card fiber D/D information: Vendor name |
| 1.3.6.1.4.1.4756.20.61.20.1.43 | Columnf100IDDPartNoRemote | read-only | current | Remote FRM220-10/100I card fiber D/D information: Vendor part number |
| 1.3.6.1.4.1.4756.20.61.20.1.44 | Columnf100IDDFiberTypeRemote | read-only | current | Remote FRM220-10/100I card fiber D/D information: Fiber Type |
| 1.3.6.1.4.1.4756.20.61.20.1.45 | Columnf100IDDWaveLenRemote | read-only | current | Remote FRM220-10/100I card fiber D/D information: Wave length |
| 1.3.6.1.4.1.4756.20.61.20.1.46 | Columnf100IDDWaveLen2Remote | read-only | current | Remote FRM220-10/100I card fiber D/D information: Wave length 2 |
| 1.3.6.1.4.1.4756.20.61.20.1.47 | Columnf100IDDLinkLenRemote | read-only | current | Remote FRM220-10/100I card fiber D/D information: Link length |
| 1.3.6.1.4.1.4756.20.61.20.1.48 | Columnf100IDDLenUnitRemote | read-only | current | Remote FRM220-10/100I card fiber D/D information: Length Unit |
| 1.3.6.1.4.1.4756.20.61.20.1.49 | Columnf100IDDStatusRemote | read-only | current | Remote FRM220-10/100I card fiber D/D information: Status Support |
| 1.3.6.1.4.1.4756.20.61.20.1.50 | Columnf100IDDRxSensRemote | read-only | current | Remote FRM220-10/100I card fiber D/D information: Rx Sensitivity |
| 1.3.6.1.4.1.4756.20.61.20.1.51 | Columnf100IDDTxPWRRemote | read-only | current | Remote FRM220-10/100I card fiber D/D information: Tx power |
| 1.3.6.1.4.1.4756.20.61.20.1.52 | Columnf100IDDRxPWRRemote | read-only | current | Remote FRM220-10/100I card fiber D/D information: Rx power |
| 1.3.6.1.4.1.4756.20.61.20.1.53 | Columnf100IDDTempRemote | read-only | current | Remote FRM220-10/100I card fiber D/D information: Temperature in degree C |
| 1.3.6.1.4.1.4756.20.61.20.1.54 | Columnf100IDDPWRMarginRemote | read-only | current | Remote FRM220-10/100I card fiber D/D information: Power margin |
| 1.3.6.1.4.1.4756.20.61.20.1.55 | Columnf100IDDPWRLossRemote | read-only | current | Remote FRM220-10/100I card fiber D/D information: Power loss |
| 1.3.6.1.4.1.4756.20.61.20.1.56 | Columnf100IInfoR1SN1Remote | read-only | current | Remote FRM220-10/100I card INFORemoteOM S/N 1 information |
| 1.3.6.1.4.1.4756.20.61.20.1.57 | Columnf100IInfoR1SN2Remote | read-only | current | Remote FRM220-10/100I card INFORemoteOM S/N 2 information |
| 1.3.6.1.4.1.4756.20.62 | Nodef100IRemoteBCards | |||
| 1.3.6.1.4.1.4756.20.62.20 | Tablef100IRemoteBTable | not-accessible | current | A list of remote B FRM220-10/100I card entries. The number of entries is f100I-NoRemote. |
| 1.3.6.1.4.1.4756.20.62.20.1 | Rowf100IRemoteBEntry | not-accessible | current | An entry containing management information applicable to a particular remote FRM220-10/100I B card. |
| 1.3.6.1.4.1.4756.20.62.20.1.1 | Columnf100IChassisIndexRemoteB | read-only | current | A unique value for each local card. It is the chassis location number. |
| 1.3.6.1.4.1.4756.20.62.20.1.2 | Columnf100ISlotIndexRemoteB | read-only | current | A unique value for each remote card. It is the slot location number. |
| 1.3.6.1.4.1.4756.20.62.20.1.3 | Columnf100ICardHWVerRemoteB | read-only | current | RemoteB FRM220-10/100I card hardware version x.xxx |
| 1.3.6.1.4.1.4756.20.62.20.1.4 | Columnf100ICardFWVerRemoteB | read-only | current | RemoteB FRM220-10/100I card firmware version x.xxx |
| 1.3.6.1.4.1.4756.20.62.20.1.5 | Columnf100ICardCPLDVerRemoteB | read-only | current | RemoteB FRM220-10/100I card CPLD version x.xxx |
| 1.3.6.1.4.1.4756.20.62.20.1.6 | Columnf100ICardFPGAVerRemoteB | read-only | current | RemoteB FRM220-10/100I card FPGA version x.xxx |
| 1.3.6.1.4.1.4756.20.62.20.1.7 | Columnf100IPortActiveRemoteB | read-only | current | RemoteB FRM220-10/100I card active: (It is read-only in remote side.) 0:Inactive 1:Active |
| 1.3.6.1.4.1.4756.20.62.20.1.8 | Columnf100IInBandManagRemoteB | read-only | current | (Local only) FRM220-10/100I card manages remote: 0:Disable 1:Enable |
| 1.3.6.1.4.1.4756.20.62.20.1.9 | Columnf100IUtpLinkRemoteB | read-only | current | RemoteB FRM220-10/100I card UTP link status: 0:Down 1:Up |
| 1.3.6.1.4.1.4756.20.62.20.1.10 | Columnf100IUtpRxActRemoteB | read-only | current | RemoteB FRM220-10/100I card UTP receive active status: 0:Off 1:On |
| 1.3.6.1.4.1.4756.20.62.20.1.11 | Columnf100IUtpNegoRemoteB | read-write | current | RemoteB FRM220-10/100I card UTP negotiation status: 0:Manual 1:Auto |
| 1.3.6.1.4.1.4756.20.62.20.1.12 | Columnf100IUtpSpeedRemoteB | read-write | current | RemoteB FRM220-10/100I card UTP speed: 0:10MHz 1:100MHz |
| 1.3.6.1.4.1.4756.20.62.20.1.13 | Columnf100IUtpDuplexRemoteB | read-write | current | RemoteB FRM220-10/100I card UTP duplex: 0:Half duplex mode 1:Full duplex mode |
| 1.3.6.1.4.1.4756.20.62.20.1.14 | Columnf100IUtpSpeedStatusRemoteB | read-only | current | RemoteB FRM220-10/100I card UTP speed status: 0:10MHz 1:100MHz |
| 1.3.6.1.4.1.4756.20.62.20.1.15 | Columnf100IUtpDuplexStatusRemoteB | read-only | current | RemoteB FRM220-10/100I card UTP duplex status: 0:Half duplex mode 1:Full duplex mode |
| 1.3.6.1.4.1.4756.20.62.20.1.16 | Columnf100IUtpRxByteRemoteB | read-only | current | RemoteB FRM220-10/100I card UTP-in octet counter |
| 1.3.6.1.4.1.4756.20.62.20.1.17 | Columnf100IUtpTxByteRemoteB | read-only | current | RemoteB FRM220-10/100I card UTP-out octet counter |
| 1.3.6.1.4.1.4756.20.62.20.1.18 | Columnf100IUtpFnlRxByteRemoteB | read-only | current | RemoteB FRM220-10/100I card UTP-in final octets |
| 1.3.6.1.4.1.4756.20.62.20.1.19 | Columnf100IUtpFnlTxByteRemoteB | read-only | current | RemoteB FRM220-10/100I card UTP-out final octets |
| 1.3.6.1.4.1.4756.20.62.20.1.20 | Columnf100IFxLinkRemoteB | read-only | current | RemoteB FRM220-10/100I card fiber link status: 0:Down 1:Up |
| 1.3.6.1.4.1.4756.20.62.20.1.21 | Columnf100IFxRxActRemoteB | read-only | current | RemoteB FRM220-10/100I card fiber receiver active status: 0:Off 1:On |
| 1.3.6.1.4.1.4756.20.62.20.1.22 | Columnf100IFxFEFRemoteB | read-only | current | RemoteB FRM220-10/100I card fiber detected Far End Fault: 0:Off 1:Detected |
| 1.3.6.1.4.1.4756.20.62.20.1.23 | Columnf100IFxLBTestRemoteB | read-write | current | Force local FRM220-10/100I card to do fiber LoopBack testing: 0:Off 1:Action |
| 1.3.6.1.4.1.4756.20.62.20.1.24 | Columnf100IFxLBStatusRemoteB | read-only | current | RemoteB FRM220-10/100I card fiber LoopBack testing status: 0:Off 1:Ok 2:Fail |
| 1.3.6.1.4.1.4756.20.62.20.1.25 | Columnf100IFxRemoPWRAbRemoteB | read-only | current | RemoteB FRM220-10/100I card fiber RemoteB Power status: 0:Abnormal 1:OK |
| 1.3.6.1.4.1.4756.20.62.20.1.26 | Columnf100IIrlModeRemoteB | read-write | current | RemoteB FRM220-10/100I card Ingress Rate Limit mode: 0:No limit 1:n x 32K 2:n x 512K |
| 1.3.6.1.4.1.4756.20.62.20.1.27 | Columnf100IIrlMultRemoteB | read-write | current | RemoteB FRM220-10/100I card Ingress Rate Limit multiple: When the irlModeRemoteB is n x 32K mode, the irlMultRemoteB should be the value between 0 to 255; When… |
| 1.3.6.1.4.1.4756.20.62.20.1.28 | Columnf100IErlModeRemoteB | read-write | current | RemoteB FRM220-10/100I card Egress Rate Limit mode: 0:No limit 1:n x 32K 2:n x 512K |
| 1.3.6.1.4.1.4756.20.62.20.1.29 | Columnf100IErlMultRemoteB | read-write | current | RemoteB FRM220-10/100I card Egress Rate Limit multiple: When the erlModeRemoteB is n x 32K mode, the erlMultRemoteB should be the value between 0 to 255; When … |
| 1.3.6.1.4.1.4756.20.62.20.1.30 | Columnf100IFxRxByteRemoteB | read-only | current | RemoteB FRM220-10/100I card FX-in octet counter |
| 1.3.6.1.4.1.4756.20.62.20.1.31 | Columnf100IFxTxByteRemoteB | read-only | current | RemoteB FRM220-10/100I card FX-out octet counter |
| 1.3.6.1.4.1.4756.20.62.20.1.32 | Columnf100IFxFnlRxByteRemoteB | read-only | current | RemoteB FRM220-10/100I card FX-in final octets |
| 1.3.6.1.4.1.4756.20.62.20.1.33 | Columnf100IFxFnlTxByteRemoteB | read-only | current | RemoteB FRM220-10/100I card FX-out final octets |
| 1.3.6.1.4.1.4756.20.62.20.1.34 | Columnf100IPortResetRemoteB | read-write | current | Force remote FRM220-10/100I card to reset mode: 0:Off 1:Action |
| 1.3.6.1.4.1.4756.20.62.20.1.35 | Columnf100IClrCountersRemoteB | read-write | current | Force remote FRM220-10/100I card to clear all counters: 0:Off 1:Action |
| 1.3.6.1.4.1.4756.20.62.20.1.36 | Columnf100IOpModeRemoteB | read-write | current | RemoteB FRM220-10/100I card operation mode: 0:Switch mode 1:Converter mode |
| 1.3.6.1.4.1.4756.20.62.20.1.37 | Columnf100ILfpModeRemoteB | read-write | current | RemoteB FRM220-10/100I card Link Fault Pass-through mode: 0:Disable 1:Enable |
| 1.3.6.1.4.1.4756.20.62.20.1.38 | Columnf100IAlsModeRemoteB | read-write | current | RemoteB FRM220-10/100I card Auto Laser Shutdown mode: 0:Disable 1:Enable |
| 1.3.6.1.4.1.4756.20.62.20.1.39 | Columnf100IFhrModeRemoteB | read-write | current | RemoteB FRM220-10/100I card accepts Fiber Hardware Reset mode: 0:Disable 1:Enable |
| 1.3.6.1.4.1.4756.20.62.20.1.40 | Columnf100ISettoDefaultRemoteB | read-write | current | RemoteB FRM220-10/100I card set to default: 0:Disable 1:Enable |
| 1.3.6.1.4.1.4756.20.62.20.1.41 | Columnf100IFxDDRemoteB | read-only | current | RemoteB FRM220-10/100I card fiber Digital Diagnostic function: 0:No 1:Yes |
| 1.3.6.1.4.1.4756.20.62.20.1.42 | Columnf100IDDVendorRemoteB | read-only | current | RemoteB FRM220-10/100I card fiber D/D information: Vendor name |
| 1.3.6.1.4.1.4756.20.62.20.1.43 | Columnf100IDDPartNoRemoteB | read-only | current | RemoteB FRM220-10/100I card fiber D/D information: Vendor part number |
| 1.3.6.1.4.1.4756.20.62.20.1.44 | Columnf100IDDFiberTypeRemoteB | read-only | current | RemoteB FRM220-10/100I card fiber D/D information: Fiber Type |
| 1.3.6.1.4.1.4756.20.62.20.1.45 | Columnf100IDDWaveLenRemoteB | read-only | current | RemoteB FRM220-10/100I card fiber D/D information: Wave length |
| 1.3.6.1.4.1.4756.20.62.20.1.46 | Columnf100IDDWaveLen2RemoteB | read-only | current | RemoteB FRM220-10/100I card fiber D/D information: Wave length 2 |
| 1.3.6.1.4.1.4756.20.62.20.1.47 | Columnf100IDDLinkLenRemoteB | read-only | current | RemoteB FRM220-10/100I card fiber D/D information: Link length |
| 1.3.6.1.4.1.4756.20.62.20.1.48 | Columnf100IDDLenUnitRemoteB | read-only | current | RemoteB FRM220-10/100I card fiber D/D information: Length Unit |
| 1.3.6.1.4.1.4756.20.62.20.1.49 | Columnf100IDDStatusRemoteB | read-only | current | RemoteB FRM220-10/100I card fiber D/D information: Status Support |
| 1.3.6.1.4.1.4756.20.62.20.1.50 | Columnf100IDDRxSensRemoteB | read-only | current | RemoteB FRM220-10/100I card fiber D/D information: Rx Sensitivity |
| 1.3.6.1.4.1.4756.20.62.20.1.51 | Columnf100IDDTxPWRRemoteB | read-only | current | RemoteB FRM220-10/100I card fiber D/D information: Tx power |
| 1.3.6.1.4.1.4756.20.62.20.1.52 | Columnf100IDDRxPWRRemoteB | read-only | current | RemoteB FRM220-10/100I card fiber D/D information: Rx power |
| 1.3.6.1.4.1.4756.20.62.20.1.53 | Columnf100IDDTempRemoteB | read-only | current | RemoteB FRM220-10/100I card fiber D/D information: Temperature in degree C |
| 1.3.6.1.4.1.4756.20.62.20.1.54 | Columnf100IDDPWRMarginRemoteB | read-only | current | RemoteB FRM220-10/100I card fiber D/D information: Power margin |
| 1.3.6.1.4.1.4756.20.62.20.1.55 | Columnf100IDDPWRLossRemoteB | read-only | current | RemoteB FRM220-10/100I card fiber D/D information: Power loss |
| 1.3.6.1.4.1.4756.20.62.20.1.56 | Columnf100IInfoR1SN1RemoteB | read-only | current | RemoteB FRM220-10/100I card INFORemoteBOM S/N 1 information |
| 1.3.6.1.4.1.4756.20.62.20.1.57 | Columnf100IInfoR1SN2RemoteB | read-only | current | RemoteB FRM220-10/100I card INFORemoteBOM S/N 2 information |
| 1.3.6.1.4.1.4756.20.70 | NodefxoFXSLocalCards | |||
| 1.3.6.1.4.1.4756.20.70.20 | TablefxoFXSLocalTable | not-accessible | current | A list of local FRM220-FXO/FXS card entries. The number of entries is fxoFXS-No-L. |
| 1.3.6.1.4.1.4756.20.70.20.1 | RowfxoFXSLocalEntry | not-accessible | current | An entry containing management information applicable to a particular local FRM220-FXO/FXS card. |
| 1.3.6.1.4.1.4756.20.70.20.1.1 | ColumnfxoFXSChassisIndexLocal | read-only | current | A unique value for each local card. It is the chassis location number. |
| 1.3.6.1.4.1.4756.20.70.20.1.2 | ColumnfxoFXSSlotIndexLocal | read-only | current | A unique value for each local card. It is the slot location number. |
| 1.3.6.1.4.1.4756.20.70.20.1.3 | ColumnfxoFXSCardHWVerLocal | read-only | current | Local FRM220-FXO/FXS card hardware version x.xxx |
| 1.3.6.1.4.1.4756.20.70.20.1.4 | ColumnfxoFXSCardFWVerLocal | read-only | current | Local FRM220-FXO/FXS card firmware version x.xxx |
| 1.3.6.1.4.1.4756.20.70.20.1.5 | ColumnfxoFXSCardCPLDVerLocal | read-only | current | Local FRM220-FXO/FXS card CPLD version x.xxx |
| 1.3.6.1.4.1.4756.20.70.20.1.6 | ColumnfxoFXSCardFPGAVerLocal | read-only | current | Local FRM220-FXO/FXS card FPGA version x.xxx |
| 1.3.6.1.4.1.4756.20.70.20.1.7 | ColumnfxoFXSPortActiveLocal | read-write | current | Local FRM220-FXO/FXS card active: 0:Inactive 1:Active |
| 1.3.6.1.4.1.4756.20.70.20.1.8 | ColumnfxoFXSActiveStsLocal | read-only | current | Local FRM220-FXO/FXS FXO/FXS active state: 0:inactive 1:active |
| 1.3.6.1.4.1.4756.20.70.20.1.9 | ColumnfxoFXSRingStsLocal | read-only | current | Local FRM220-FXO/FXS card ring state: 0:noring 1:ringing |
| 1.3.6.1.4.1.4756.20.70.20.1.10 | ColumnfxoFXSFXSHookLocal | read-only | current | Local FRM220-FXO/FXS card FXS ON/OFF hook: 0:on-hook 1:off-hook |
| 1.3.6.1.4.1.4756.20.70.20.1.11 | ColumnfxoFXSFxLinkLocal | read-only | current | Local FRM220-FXO/FXS fiber link state: 0:Link Down 1:Link Up |
| 1.3.6.1.4.1.4756.20.70.20.1.12 | ColumnfxoFXSFxSignalLocal | read-only | current | Local FRM220-FXO/FXS fiber signal detected: 0:No 1:Yes |
| 1.3.6.1.4.1.4756.20.70.20.1.13 | ColumnfxoFXSFxFEFLocal | read-only | current | Local FRM220-FXO/FXS card fiber detected Far End Fault: 0:Off 1:Detected |
| 1.3.6.1.4.1.4756.20.70.20.1.14 | ColumnfxoFXSPortResetLocal | read-write | current | Force remote FRM220-FXO/FXS card to reset mode: 0:Off 1:Action |
| 1.3.6.1.4.1.4756.20.70.20.1.15 | ColumnfxoFXSSetDefaultLocal | read-write | current | Force remote FRM220-FXO/FXS card to default status: 0:Off 1:Action |
| 1.3.6.1.4.1.4756.20.70.20.1.16 | ColumnfxoFXSOpModeLocal | read-write | current | Local FRM220-FXO/FXS card operation mode: 0:FXO 1:FXS (20~35Hz) 2:FXS (40~55Hz) 3:FXS Leased Mode |
| 1.3.6.1.4.1.4756.20.70.20.1.17 | ColumnfxoFXSRingFreqLocal | read-write | current | Local FRM220-FXO/FXS card ring frequency select: 0:50~55Hz 1:40~45Hz 2:30~35Hz 3:20~25Hz 4:55Hz 5:50Hz 6:45Hz 7:40Hz 8:35Hz 9:30Hz 10:25Hz 11:20Hz |
| 1.3.6.1.4.1.4756.20.70.20.1.18 | ColumnfxoFXSTimingSelectLocal | read-write | current | Local FRM220-FXO/FXS card timing select: 0:Salve 1:Master |
| 1.3.6.1.4.1.4756.20.70.20.1.19 | ColumnfxoFXSLeasedLineLocal | read-write | current | Local FRM220-FXO/FXS card leased line mode: 0:Mode2 1:Mode1 |
| 1.3.6.1.4.1.4756.20.70.20.1.20 | ColumnfxoFXSAlsModeLocal | read-write | current | Local FRM220-FXO/FXS card Auto Laser Shutdown mode: 0:Disable 1:Enable |
| 1.3.6.1.4.1.4756.20.70.20.1.21 | ColumnfxoFXSFxDDLocal | read-only | current | Local FRM220-FXO/FXS card fiber Digital Diagnostic function: 0:No 1:Yes |
| 1.3.6.1.4.1.4756.20.70.20.1.22 | ColumnfxoFXSDDVendorLocal | read-only | current | Local FRM220-FXO/FXS card fiber D/D information: Vendor name |
| 1.3.6.1.4.1.4756.20.70.20.1.23 | ColumnfxoFXSDDPartNoLocal | read-only | current | Local FRM220-FXO/FXS card fiber D/D information: Vendor part number |
| 1.3.6.1.4.1.4756.20.70.20.1.24 | ColumnfxoFXSDDFiberTypeLocal | read-only | current | Local FRM220-FXO/FXS card fiber D/D information: Fiber Type |
| 1.3.6.1.4.1.4756.20.70.20.1.25 | ColumnfxoFXSDDWaveLenLocal | read-only | current | Local FRM220-FXO/FXS card fiber D/D information: Wave length |
| 1.3.6.1.4.1.4756.20.70.20.1.26 | ColumnfxoFXSDDWaveLen2Local | read-only | current | Local FRM220-FXO/FXS card fiber D/D information: Wave length 2 |
| 1.3.6.1.4.1.4756.20.70.20.1.27 | ColumnfxoFXSDDLinkLenLocal | read-only | current | Local FRM220-FXO/FXS card fiber D/D information: Link length |
| 1.3.6.1.4.1.4756.20.70.20.1.28 | ColumnfxoFXSDDLenUnitLocal | read-only | current | Local FRM220-FXO/FXS card fiber D/D information: Length Unit |
| 1.3.6.1.4.1.4756.20.70.20.1.29 | ColumnfxoFXSDDStatusLocal | read-only | current | Local FRM220-FXO/FXS card fiber D/D information: Status Support |
| 1.3.6.1.4.1.4756.20.70.20.1.30 | ColumnfxoFXSDDRxSensLocal | read-only | current | Local FRM220-FXO/FXS card fiber D/D information: Rx Sensitivity |
| 1.3.6.1.4.1.4756.20.70.20.1.31 | ColumnfxoFXSDDTxPwrLocal | read-only | current | Local FRM220-FXO/FXS card fiber D/D information: Tx power |
| 1.3.6.1.4.1.4756.20.70.20.1.32 | ColumnfxoFXSDDRxPwrLocal | read-only | current | Local FRM220-FXO/FXS card fiber D/D information: Rx power |
| 1.3.6.1.4.1.4756.20.70.20.1.33 | ColumnfxoFXSDDTempLocal | read-only | current | Local FRM220-FXO/FXS card fiber D/D information: Temperature in degree C |
| 1.3.6.1.4.1.4756.20.70.20.1.34 | ColumnfxoFXSDDPwrMarginLocal | read-only | current | Local FRM220-FXO/FXS card fiber D/D information: Power margin |
| 1.3.6.1.4.1.4756.20.70.20.1.35 | ColumnfxoFXSDDPwrLossLocal | read-only | current | Local FRM220-FXO/FXS card fiber D/D information: Power loss |
| 1.3.6.1.4.1.4756.20.71 | NodefxoFXSRemoteCards | |||
| 1.3.6.1.4.1.4756.20.71.20 | TablefxoFXSRemoteTable | not-accessible | current | A list of local FRM220-FXO/FXS card entries. The number of entries is fxoFXS-NoRemote. |
| 1.3.6.1.4.1.4756.20.71.20.1 | RowfxoFXSRemoteEntry | not-accessible | current | An entry containing management information applicable to a particular local FRM220-FXO/FXS card. |
| 1.3.6.1.4.1.4756.20.71.20.1.1 | ColumnfxoFXSChassisIndexRemote | read-only | current | A unique value for each local card. It is the chassis location number. |
| 1.3.6.1.4.1.4756.20.71.20.1.2 | ColumnfxoFXSSlotIndexRemote | read-only | current | A unique value for each remote card. It is the slot location number. |
| 1.3.6.1.4.1.4756.20.71.20.1.3 | ColumnfxoFXSCardHWVerRemote | read-only | current | Remote FRM220-FXO/FXS card hardware version x.xxx |
| 1.3.6.1.4.1.4756.20.71.20.1.4 | ColumnfxoFXSCardFWVerRemote | read-only | current | Remote FRM220-FXO/FXS card firmware version x.xxx |
| 1.3.6.1.4.1.4756.20.71.20.1.5 | ColumnfxoFXSCardCPLDVerRemote | read-only | current | Remote FRM220-FXO/FXS card CPLD version x.xxx |
| 1.3.6.1.4.1.4756.20.71.20.1.6 | ColumnfxoFXSCardFPGAVerRemote | read-only | current | Remote FRM220-FXO/FXS card FPGA version x.xxx |
| 1.3.6.1.4.1.4756.20.71.20.1.7 | ColumnfxoFXSPortActiveRemote | read-only | current | Remote FRM220-FXO/FXS card active: 0:Inactive 1:Active |
| 1.3.6.1.4.1.4756.20.71.20.1.8 | ColumnfxoFXSActiveStsRemote | read-only | current | Remote FRM220-FXO/FXS FXO/FXS active state: 0:inactive 1:active |
| 1.3.6.1.4.1.4756.20.71.20.1.9 | ColumnfxoFXSRingStsRemote | read-only | current | Remote FRM220-FXO/FXS card ring state: 0:noring 1:ringing |
| 1.3.6.1.4.1.4756.20.71.20.1.10 | ColumnfxoFXSFXSHookRemote | read-only | current | Remote FRM220-FXO/FXS card FXS ON/OFF hook: 0:on-hook 1:off-hook |
| 1.3.6.1.4.1.4756.20.71.20.1.11 | ColumnfxoFXSFxLinkRemote | read-only | current | Remote FRM220-FXO/FXS fiber link state: 0:Link Down 1:Link Up |
| 1.3.6.1.4.1.4756.20.71.20.1.12 | ColumnfxoFXSFxSignalRemote | read-only | current | Remote FRM220-FXO/FXS fiber signal detected: 0:No 1:Yes |
| 1.3.6.1.4.1.4756.20.71.20.1.13 | ColumnfxoFXSFxFEFRemote | read-only | current | Remote FRM220-FXO/FXS card fiber detected Far End Fault: 0:Off 1:Detected |
| 1.3.6.1.4.1.4756.20.71.20.1.14 | ColumnfxoFXSPortResetRemote | read-write | current | Force remote FRM220-FXO/FXS card to reset mode: 0:Off 1:Action |
| 1.3.6.1.4.1.4756.20.71.20.1.15 | ColumnfxoFXSSetDefaultRemote | read-write | current | Force remote FRM220-FXO/FXS card to default status: 0:Off 1:Action |
| 1.3.6.1.4.1.4756.20.71.20.1.16 | ColumnfxoFXSOpModeRemote | read-write | current | Remote FRM220-FXO/FXS card operation mode: 0:FXO 1:FXS (20~35) 2:FXS (40~55Hz) 3:FXS Leased Mode |
| 1.3.6.1.4.1.4756.20.71.20.1.17 | ColumnfxoFXSRingFreqRemote | read-write | current | Remote FRM220-FXO/FXS card ring frequency select: 0:50~55Hz 1:40~45Hz 2:30~35Hz 3:20~25Hz 4:55Hz 5:50Hz 6:45Hz 7:40Hz 8:35Hz 9:30Hz 10:25Hz 11:20Hz |
| 1.3.6.1.4.1.4756.20.71.20.1.18 | ColumnfxoFXSTimingSelectRemote | read-write | current | Remote FRM220-FXO/FXS card timing select: 0:Salve 1:Master |
| 1.3.6.1.4.1.4756.20.71.20.1.19 | ColumnfxoFXSLeasedLineRemote | read-write | current | Remote FRM220-FXO/FXS card leased line mode: 0:Mode2 1:Mode1 |
| 1.3.6.1.4.1.4756.20.71.20.1.20 | ColumnfxoFXSAlsModeRemote | read-write | current | Remote FRM220-FXO/FXS card Auto Laser Shutdown mode: 0:Disable 1:Enable |
| 1.3.6.1.4.1.4756.20.71.20.1.21 | ColumnfxoFXSFxDDRemote | read-only | current | Remote FRM220-FXO/FXS card fiber Digital Diagnostic function: 0:No 1:Yes |
| 1.3.6.1.4.1.4756.20.71.20.1.22 | ColumnfxoFXSDDVendorRemote | read-only | current | Remote FRM220-FXO/FXS card fiber D/D information: Vendor name |
| 1.3.6.1.4.1.4756.20.71.20.1.23 | ColumnfxoFXSDDPartNoRemote | read-only | current | Remote FRM220-FXO/FXS card fiber D/D information: Vendor part number |
| 1.3.6.1.4.1.4756.20.71.20.1.24 | ColumnfxoFXSDDFiberTypeRemote | read-only | current | Remote FRM220-FXO/FXS card fiber D/D information: Fiber Type |
| 1.3.6.1.4.1.4756.20.71.20.1.25 | ColumnfxoFXSDDWaveLenRemote | read-only | current | Remote FRM220-FXO/FXS card fiber D/D information: Wave length |
| 1.3.6.1.4.1.4756.20.71.20.1.26 | ColumnfxoFXSDDWaveLen2Remote | read-only | current | Remote FRM220-FXO/FXS card fiber D/D information: Wave length 2 |
| 1.3.6.1.4.1.4756.20.71.20.1.27 | ColumnfxoFXSDDLinkLenRemote | read-only | current | Remote FRM220-FXO/FXS card fiber D/D information: Link length |
| 1.3.6.1.4.1.4756.20.71.20.1.28 | ColumnfxoFXSDDLenUnitRemote | read-only | current | Remote FRM220-FXO/FXS card fiber D/D information: Length Unit |
| 1.3.6.1.4.1.4756.20.71.20.1.29 | ColumnfxoFXSDDStatusRemote | read-only | current | Remote FRM220-FXO/FXS card fiber D/D information: Status Support |
| 1.3.6.1.4.1.4756.20.71.20.1.30 | ColumnfxoFXSDDRxSensRemote | read-only | current | Remote FRM220-FXO/FXS card fiber D/D information: Rx Sensitivity |
| 1.3.6.1.4.1.4756.20.71.20.1.31 | ColumnfxoFXSDDTxPwrRemote | read-only | current | Remote FRM220-FXO/FXS card fiber D/D information: Tx power |
| 1.3.6.1.4.1.4756.20.71.20.1.32 | ColumnfxoFXSDDRxPwrRemote | read-only | current | Remote FRM220-FXO/FXS card fiber D/D information: Rx power |
| 1.3.6.1.4.1.4756.20.71.20.1.33 | ColumnfxoFXSDDTempRemote | read-only | current | Remote FRM220-FXO/FXS card fiber D/D information: Temperature in degree C |
| 1.3.6.1.4.1.4756.20.71.20.1.34 | ColumnfxoFXSDDPwrMarginRemote | read-only | current | Remote FRM220-FXO/FXS card fiber D/D information: Power margin |
| 1.3.6.1.4.1.4756.20.71.20.1.35 | ColumnfxoFXSDDPwrLossRemote | read-only | current | Remote FRM220-FXO/FXS card fiber D/D information: Power loss |
| 1.3.6.1.4.1.4756.20.80 | NodefSERIALLocalCards | |||
| 1.3.6.1.4.1.4756.20.80.20 | TablefSERIALLocalTable | not-accessible | current | A list of local FRM220-SERIAL card entries. The number of entries is fSERIAL-No-L. |
| 1.3.6.1.4.1.4756.20.80.20.1 | RowfSERIALLocalEntry | not-accessible | current | An entry containing management information applicable to a particular local FRM220-SERIAL card. |
| 1.3.6.1.4.1.4756.20.80.20.1.1 | ColumnfSERIALChassisIndexLocal | read-only | current | A unique value for each local card. It is the chassis location number. |
| 1.3.6.1.4.1.4756.20.80.20.1.2 | ColumnfSERIALSlotIndexLocal | read-only | current | A unique value for each local card. It is the slot location number. |
| 1.3.6.1.4.1.4756.20.80.20.1.3 | ColumnfSERIALCardHWVerLocal | read-only | current | Local FRM220-SERIAL card hardware version x.xxx |
| 1.3.6.1.4.1.4756.20.80.20.1.4 | ColumnfSERIALCardFWVerLocal | read-only | current | Local FRM220-SERIAL card firmware version x.xxx |
| 1.3.6.1.4.1.4756.20.80.20.1.5 | ColumnfSERIALCardCPLDVerLocal | read-only | current | Local FRM220-SERIAL card CPLD version x.xxx |
| 1.3.6.1.4.1.4756.20.80.20.1.6 | ColumnfSERIALCardFPGAVerLocal | read-only | current | Local FRM220-SERIAL card FPGA version x.xxx |
| 1.3.6.1.4.1.4756.20.80.20.1.7 | ColumnfSERIALPortActiveLocal | read-write | current | Local FRM220-SERIAL card active: 0:Inactive 1:Active |
| 1.3.6.1.4.1.4756.20.80.20.1.8 | ColumnfSERIALDiStateLocal | read-only | current | Local FRM220-SERIAL data in state: 0:Space 1:Mark 2:Flash |
| 1.3.6.1.4.1.4756.20.80.20.1.9 | ColumnfSERIALDoStateLocal | read-only | current | Local FRM220-SERIAL data out state: 0:Space 1:Mark 2:Flash |
| 1.3.6.1.4.1.4756.20.80.20.1.10 | ColumnfSERIALFxLinkLocal | read-only | current | Local FRM220-SERIAL fiber link state: 0:Link Down 1:Link Up |
| 1.3.6.1.4.1.4756.20.80.20.1.11 | ColumnfSERIALFxSignalLocal | read-only | current | Local FRM220-SERIAL fiber signal detected: 0:No 1:Yes |
| 1.3.6.1.4.1.4756.20.80.20.1.12 | ColumnfSERIALFxFEFLocal | read-only | current | Local FRM220-SERIAL card fiber detected Far End Fault: 0:Off 1:Detected |
| 1.3.6.1.4.1.4756.20.80.20.1.13 | ColumnfSERIALPortResetLocal | read-write | current | Force local FRM220-SERIAL card to reset mode: 0:Off 1:Action |
| 1.3.6.1.4.1.4756.20.80.20.1.14 | ColumnfSERIALSetDefaultLocal | read-write | current | Force local FRM220-SERIAL card to default status: 0:Off 1:Action |
| 1.3.6.1.4.1.4756.20.80.20.1.15 | ColumnfSERIALSerialModeLocal | read-write | current | Local FRM220-SERIAL card fSERIAL- port mode: 0:RS-422 1:RS-485 2:RS-232 5 wire 3:RS-232 3 wire |
| 1.3.6.1.4.1.4756.20.80.20.1.16 | ColumnfSERIALAlsModeLocal | read-write | current | Local FRM220-SERIAL card Auto Laser Shutdown mode: 0:Disable 1:Enable |
| 1.3.6.1.4.1.4756.20.80.20.1.17 | ColumnfSERIALFxDDLocal | read-only | current | Local FRM220-SERIAL card fiber Digital Diagnostic function: 0:No 1:Yes |
| 1.3.6.1.4.1.4756.20.80.20.1.18 | ColumnfSERIALDDVendorLocal | read-only | current | Local FRM220-SERIAL card fiber D/D information: Vendor name |
| 1.3.6.1.4.1.4756.20.80.20.1.19 | ColumnfSERIALDDPartNoLocal | read-only | current | Local FRM220-SERIAL card fiber D/D information: Vendor part number |
| 1.3.6.1.4.1.4756.20.80.20.1.20 | ColumnfSERIALDDFiberTypeLocal | read-only | current | Local FRM220-SERIAL card fiber D/D information: Fiber Type |
| 1.3.6.1.4.1.4756.20.80.20.1.21 | ColumnfSERIALDDWaveLenLocal | read-only | current | Local FRM220-SERIAL card fiber D/D information: Wave length |
| 1.3.6.1.4.1.4756.20.80.20.1.22 | ColumnfSERIALDDWaveLen2Local | read-only | current | Local FRM220-SERIAL card fiber D/D information: Wave length 2 |
| 1.3.6.1.4.1.4756.20.80.20.1.23 | ColumnfSERIALDDLinkLenLocal | read-only | current | Local FRM220-SERIAL card fiber D/D information: Link length |
| 1.3.6.1.4.1.4756.20.80.20.1.24 | ColumnfSERIALDDLenUnitLocal | read-only | current | Local FRM220-SERIAL card fiber D/D information: Length Unit |
| 1.3.6.1.4.1.4756.20.80.20.1.25 | ColumnfSERIALDDStatusLocal | read-only | current | Local FRM220-SERIAL card fiber D/D information: Status Support |
| 1.3.6.1.4.1.4756.20.80.20.1.26 | ColumnfSERIALDDRxSensLocal | read-only | current | Local FRM220-SERIAL card fiber D/D information: Rx Sensitivity |
| 1.3.6.1.4.1.4756.20.80.20.1.27 | ColumnfSERIALDDTxPwrLocal | read-only | current | Local FRM220-SERIAL card fiber D/D information: Tx power |
| 1.3.6.1.4.1.4756.20.80.20.1.28 | ColumnfSERIALDDRxPwrLocal | read-only | current | Local FRM220-SERIAL card fiber D/D information: Rx power |
| 1.3.6.1.4.1.4756.20.80.20.1.29 | ColumnfSERIALDDTempLocal | read-only | current | Local FRM220-SERIAL card fiber D/D information: Temperature in degree C |
| 1.3.6.1.4.1.4756.20.80.20.1.30 | ColumnfSERIALDDPwrMarginLocal | read-only | current | Local FRM220-SERIAL card fiber D/D information: Power margin |
| 1.3.6.1.4.1.4756.20.80.20.1.31 | ColumnfSERIALDDPwrLossLocal | read-only | current | Local FRM220-SERIAL card fiber D/D information: Power loss |
| 1.3.6.1.4.1.4756.20.81 | NodefSERIALRemoteCards | |||
| 1.3.6.1.4.1.4756.20.81.20 | TablefSERIALRemoteTable | not-accessible | current | A list of local FRM220-SERIAL card entries. The number of entries is fSERIAL-NoRemote. |
| 1.3.6.1.4.1.4756.20.81.20.1 | RowfSERIALRemoteEntry | not-accessible | current | An entry containing management information applicable to a particular local FRM220-SERIAL card. |
| 1.3.6.1.4.1.4756.20.81.20.1.1 | ColumnfSERIALChassisIndexRemote | read-only | current | A unique value for each local card. It is the chassis location number. |
| 1.3.6.1.4.1.4756.20.81.20.1.2 | ColumnfSERIALSlotIndexRemote | read-only | current | A unique value for each local card. It is the slot location number. |
| 1.3.6.1.4.1.4756.20.81.20.1.3 | ColumnfSERIALCardHWVerRemote | read-only | current | Remote FRM220-SERIAL card hardware version x.xxx |
| 1.3.6.1.4.1.4756.20.81.20.1.4 | ColumnfSERIALCardFWVerRemote | read-only | current | Remote FRM220-SERIAL card firmware version x.xxx |
| 1.3.6.1.4.1.4756.20.81.20.1.5 | ColumnfSERIALCardCPLDVerRemote | read-only | current | Remote FRM220-SERIAL card CPLD version x.xxx |
| 1.3.6.1.4.1.4756.20.81.20.1.6 | ColumnfSERIALCardFPGAVerRemote | read-only | current | Remote FRM220-SERIAL card FPGA version x.xxx |
| 1.3.6.1.4.1.4756.20.81.20.1.7 | ColumnfSERIALPortActiveRemote | read-only | current | Remote FRM220-SERIAL card active: 0:Inactive 1:Active |
| 1.3.6.1.4.1.4756.20.81.20.1.8 | ColumnfSERIALDiStateRemote | read-only | current | Remote FRM220-SERIAL data in state: 0:Space 1:Mark 2:Flash |
| 1.3.6.1.4.1.4756.20.81.20.1.9 | ColumnfSERIALDoStateRemote | read-only | current | Remote FRM220-SERIAL data out state: 0:Space 1:Mark 2:Flash |
| 1.3.6.1.4.1.4756.20.81.20.1.10 | ColumnfSERIALFxLinkRemote | read-only | current | Remote FRM220-SERIAL fiber link state: 0:Link Down 1:Link Up |
| 1.3.6.1.4.1.4756.20.81.20.1.11 | ColumnfSERIALFxSignalRemote | read-only | current | Remote FRM220-SERIAL fiber signal detected: 0:No 1:Yes |
| 1.3.6.1.4.1.4756.20.81.20.1.12 | ColumnfSERIALFxFEFRemote | read-only | current | Remote FRM220-SERIAL card fiber detected Far End Fault: 0:Off 1:Detected |
| 1.3.6.1.4.1.4756.20.81.20.1.13 | ColumnfSERIALPortResetRemote | read-write | current | Force remote FRM220-SERIAL card to reset mode: 0:Off 1:Action |
| 1.3.6.1.4.1.4756.20.81.20.1.14 | ColumnfSERIALSetDefaultRemote | read-write | current | Force remote FRM220-SERIAL card to default status: 0:Off 1:Action |
| 1.3.6.1.4.1.4756.20.81.20.1.15 | ColumnfSERIALSerialModeRemote | read-write | current | Remote FRM220-SERIAL card fSERIAL- port mode: 0:RS-422 1:RS-485 2:RS-232 5 wire 3:RS-232 3 wire |
| 1.3.6.1.4.1.4756.20.81.20.1.16 | ColumnfSERIALAlsModeRemote | read-write | current | Remote FRM220-SERIAL card Auto Laser Shutdown mode: 0:Disable 1:Enable |
| 1.3.6.1.4.1.4756.20.81.20.1.17 | ColumnfSERIALFxDDRemote | read-only | current | Remote FRM220-SERIAL card fiber Digital Diagnostic function: 0:No 1:Yes |
| 1.3.6.1.4.1.4756.20.81.20.1.18 | ColumnfSERIALDDVendorRemote | read-only | current | Remote FRM220-SERIAL card fiber D/D information: Vendor name |
| 1.3.6.1.4.1.4756.20.81.20.1.19 | ColumnfSERIALDDPartNoRemote | read-only | current | Remote FRM220-SERIAL card fiber D/D information: Vendor part number |
| 1.3.6.1.4.1.4756.20.81.20.1.20 | ColumnfSERIALDDFiberTypeRemote | read-only | current | Remote FRM220-SERIAL card fiber D/D information: Fiber Type |
| 1.3.6.1.4.1.4756.20.81.20.1.21 | ColumnfSERIALDDWaveLenRemote | read-only | current | Remote FRM220-SERIAL card fiber D/D information: Wave length |
| 1.3.6.1.4.1.4756.20.81.20.1.22 | ColumnfSERIALDDWaveLen2Remote | read-only | current | Remote FRM220-SERIAL card fiber D/D information: Wave length 2 |
| 1.3.6.1.4.1.4756.20.81.20.1.23 | ColumnfSERIALDDLinkLenRemote | read-only | current | Remote FRM220-SERIAL card fiber D/D information: Link length |
| 1.3.6.1.4.1.4756.20.81.20.1.24 | ColumnfSERIALDDLenUnitRemote | read-only | current | Remote FRM220-SERIAL card fiber D/D information: Length Unit |
| 1.3.6.1.4.1.4756.20.81.20.1.25 | ColumnfSERIALDDStatusRemote | read-only | current | Remote FRM220-SERIAL card fiber D/D information: Status Support |
| 1.3.6.1.4.1.4756.20.81.20.1.26 | ColumnfSERIALDDRxSensRemote | read-only | current | Remote FRM220-SERIAL card fiber D/D information: Rx Sensitivity |
| 1.3.6.1.4.1.4756.20.81.20.1.27 | ColumnfSERIALDDTxPwrRemote | read-only | current | Remote FRM220-SERIAL card fiber D/D information: Tx power |
| 1.3.6.1.4.1.4756.20.81.20.1.28 | ColumnfSERIALDDRxPwrRemote | read-only | current | Remote FRM220-SERIAL card fiber D/D information: Rx power |
| 1.3.6.1.4.1.4756.20.81.20.1.29 | ColumnfSERIALDDTempRemote | read-only | current | Remote FRM220-SERIAL card fiber D/D information: Temperature in degree C |
| 1.3.6.1.4.1.4756.20.81.20.1.30 | ColumnfSERIALDDPwrMarginRemote | read-only | current | Remote FRM220-SERIAL card fiber D/D information: Power margin |
| 1.3.6.1.4.1.4756.20.81.20.1.31 | ColumnfSERIALDDPwrLossRemote | read-only | current | Remote FRM220-SERIAL card fiber D/D information: Power loss |
| 1.3.6.1.4.1.4756.20.90 | NodefDATALocalCards | |||
| 1.3.6.1.4.1.4756.20.90.20 | TablefDATALocalTable | not-accessible | current | A list of local FRM220-DATA card entries. The number of entries is fDATA-No-L. |
| 1.3.6.1.4.1.4756.20.90.20.1 | RowfDATALocalEntry | not-accessible | current | An entry containing management information applicable to a particular local FRM220-DATA card. |
| 1.3.6.1.4.1.4756.20.90.20.1.1 | ColumnfDATAChassisIndexLocal | read-only | current | A unique value for each local card. It is the chassis location number. |
| 1.3.6.1.4.1.4756.20.90.20.1.2 | ColumnfDATASlotIndexLocal | read-only | current | A unique value for each local card. It is the slot location number. |
| 1.3.6.1.4.1.4756.20.90.20.1.3 | ColumnfDATACardHWVerLocal | read-only | current | Local FRM220-DATA card hardware version x.xxx |
| 1.3.6.1.4.1.4756.20.90.20.1.4 | ColumnfDATACardFWVerLocal | read-only | current | Local FRM220-DATA card firmware version x.xxx |
| 1.3.6.1.4.1.4756.20.90.20.1.5 | ColumnfDATACardCPLDVerLocal | read-only | current | Local FRM220-DATA card CPLD version x.xxx |
| 1.3.6.1.4.1.4756.20.90.20.1.6 | ColumnfDATACardFPGAVerLocal | read-only | current | Local FRM220-DATA card FPGA version x.xxx |
| 1.3.6.1.4.1.4756.20.90.20.1.7 | ColumnfDATAPortActiveLocal | read-write | current | Local FRM220-DATA card active: 0:Inactive 1:Active |
| 1.3.6.1.4.1.4756.20.90.20.1.8 | ColumnfDATAFxLinkLocal | read-only | current | Local FRM220-DATA fiber Link detected: 0:Link Down 1:Up |
| 1.3.6.1.4.1.4756.20.90.20.1.9 | ColumnfDATAFxSignalLocal | read-only | current | Local FRM220-DATA fiber signal detected: 0:No 1:Yes |
| 1.3.6.1.4.1.4756.20.90.20.1.10 | ColumnfDATAFxFEFLocal | read-only | current | Local FRM220-DATA card fiber detected Far End Fault: 0:Off 1:Detected |
| 1.3.6.1.4.1.4756.20.90.20.1.11 | ColumnfDATAPortResetLocal | read-write | current | Force local FRM220-DATA card to reset mode: 0:Off 1:Action |
| 1.3.6.1.4.1.4756.20.90.20.1.12 | ColumnfDATASetDefaultLocal | read-write | current | Force local FRM220-DATA card to default status: 0:Off 1:Action |
| 1.3.6.1.4.1.4756.20.90.20.1.13 | ColumnfDATARdStateLocal | read-only | current | Local FRM220-DATA card RD State: 0:on 1:off 2:flash |
| 1.3.6.1.4.1.4756.20.90.20.1.14 | ColumnfDATATdStateLocal | read-only | current | Local FRM220-DATA card TD State: 0:on 1:off 2:flash |
| 1.3.6.1.4.1.4756.20.90.20.1.15 | ColumnfDATARtsStateLocal | read-only | current | Local FRM220-DATA card RTS State: 0:on 1:off |
| 1.3.6.1.4.1.4756.20.90.20.1.16 | ColumnfDATACtsStateLocal | read-only | current | Local FRM220-DATA card CTS State: 0:on 1:off |
| 1.3.6.1.4.1.4756.20.90.20.1.17 | ColumnfDATADcdStateLocal | read-only | current | Local FRM220-DATA card DCD State: 0:on 1:off |
| 1.3.6.1.4.1.4756.20.90.20.1.18 | ColumnfDATAReDataRateGpLocal | read-write | current | Local FRM220-DATA card Receive Data Rate Group Index Receive Data Rate Group Select 0 Group 1, N*64, N from 1 to 32, 64K~2048K 1 Group 2, N*64K, N from 33 to 6… |
| 1.3.6.1.4.1.4756.20.90.20.1.19 | ColumnfDATAReDataRateLocal | read-write | current | Local FRM220-DATA card Receive Data Rate Index Receive Data Rate Select Group1 Group2 Group3 Group4 Group5 Group6 Group7 0 64K 2112K 4160K 6208K 8256K 75 Reser… |
| 1.3.6.1.4.1.4756.20.90.20.1.20 | ColumnfDATAReTimeSourceLocal | read-write | current | Local FRM220-DATA card Receive Timing Source State 0:recovery from remote transmit side 1:internal 2:etc/rc input 3:recovery from remote receive side |
| 1.3.6.1.4.1.4756.20.90.20.1.21 | ColumnfDATATrDataRateGpLocal | read-write | current | Local FRM220-DATA card Transmit Data Rate Group Index Transmit Data Rate Group Select 0 Group 1, N*64, N from 1 to 32, 64K~2048K 1 Group 2, N*64K, N from 33 to… |
| 1.3.6.1.4.1.4756.20.90.20.1.22 | ColumnfDATATrDataRateLocal | read-write | current | Local FRM220-DATA card Transmit Data Rate Index Transmit Data Rate Select Group1 Group2 Group3 Group4 Group5 Group6 Group7 0 64K 2112K 4160K 6208K 8256K 75 Res… |
| 1.3.6.1.4.1.4756.20.90.20.1.23 | ColumnfDATATrTimeSourceLocal | read-write | current | Local FRM220-DATA card Transmit Timing Source State 0:Same as Reveive Timing Source 1:internal 2:etc/rc input 3:recovery from remote receive side |
| 1.3.6.1.4.1.4756.20.90.20.1.24 | ColumnfDATADsrdtrLocal | read-write | current | Local FRM220-DATA card DSR/DTR output setting 0:constantly on 1:follow local dtr/dsr input 2:follow remote dtr/dsr input |
| 1.3.6.1.4.1.4756.20.90.20.1.25 | ColumnfDATACtsrtsLocal | read-write | current | Local FRM220-DATA card CTS/RTS output setting 0:constantly on 1:follow local cts/rts input 2:follow remote cts/rts input |
| 1.3.6.1.4.1.4756.20.90.20.1.26 | ColumnfDATAEtcLocal | read-write | current | Local FRM220-DATA card ETC polarity setting 0:normal 1:invert |
| 1.3.6.1.4.1.4756.20.90.20.1.27 | ColumnfDATATcLocal | read-write | current | Local FRM220-DATA card TC polarity setting 0:normal 1:invert |
| 1.3.6.1.4.1.4756.20.90.20.1.28 | ColumnfDATARcLocal | read-write | current | Local FRM220-DATA card RC polarity setting 0:normal 1:invert |
| 1.3.6.1.4.1.4756.20.90.20.1.29 | ColumnfDATAAlsModeLocal | read-write | current | Local FRM220-DATA card Auto Laser Shutdown mode: 0:Disable 1:Enable |
| 1.3.6.1.4.1.4756.20.90.20.1.30 | ColumnfDATADataPortModeLocal | read-write | current | Local FRM220-DATA card Data Port Mode setting 0:DCE Mode 1:DTE Mode |
| 1.3.6.1.4.1.4756.20.90.20.1.31 | ColumnfDATADataPotrinterfaceLocal | read-write | current | Local FRM220-DATA card Data Port Interface setting 0:rs530-rs-449-x21 1:v35 2:rs-232 |
| 1.3.6.1.4.1.4756.20.90.20.1.32 | ColumnfDATALbsettingLocal | read-write | current | Local FRM220-DATA card Loop Back Function & Select setting 0:off 1:fiber side llb 2:fiber side rlb 3:fiber side rrlb 5:data port side llb 6:data port side rlb … |
| 1.3.6.1.4.1.4756.20.90.20.1.33 | ColumnfDATADcdoutsetLocal | read-write | current | Local FRM220-DATA card DCD output setting 0:constantly on 1:follow remote dcd input |
| 1.3.6.1.4.1.4756.20.90.20.1.34 | ColumnfDATADsrStateLocal | read-only | current | Local FRM220-DATA card DSR State 0:On 1:Off |
| 1.3.6.1.4.1.4756.20.90.20.1.35 | ColumnfDATADtrStateLocal | read-only | current | Local FRM220-DATA card DTR State 0:On 1:Off |
| 1.3.6.1.4.1.4756.20.90.20.1.36 | ColumnfDATARlbStateLocal | read-only | current | Local FRM220-DATA card RLB State 0:On 1:Off |
| 1.3.6.1.4.1.4756.20.90.20.1.37 | ColumnfDATALlbStateLocal | read-only | current | Local FRM220-DATA card LLB State 0:On 1:Off |
| 1.3.6.1.4.1.4756.20.90.20.1.38 | ColumnfDATATmStateLocal | read-only | current | Local FRM220-DATA card TM State 0:On 1:Off |
| 1.3.6.1.4.1.4756.20.90.20.1.39 | ColumnfDATAFxDDLocal | read-only | current | Local FRM220-DATA card fiber Digital Diagnostic function: 0:No 1:Yes |
| 1.3.6.1.4.1.4756.20.90.20.1.40 | ColumnfDATADDVendorLocal | read-only | current | Local FRM220-DATA card fiber D/D information: Vendor name |
| 1.3.6.1.4.1.4756.20.90.20.1.41 | ColumnfDATADDPartNoLocal | read-only | current | Local FRM220-DATA card fiber D/D information: Vendor part number |
| 1.3.6.1.4.1.4756.20.90.20.1.42 | ColumnfDATADDFiberTypeLocal | read-only | current | Local FRM220-DATA card fiber D/D information: Fiber Type |
| 1.3.6.1.4.1.4756.20.90.20.1.43 | ColumnfDATADDWaveLenLocal | read-only | current | Local FRM220-DATA card fiber D/D information: Wave length |
| 1.3.6.1.4.1.4756.20.90.20.1.44 | ColumnfDATADDWaveLen2Local | read-only | current | Local FRM220-DATA card fiber D/D information: Wave length 2 |
| 1.3.6.1.4.1.4756.20.90.20.1.45 | ColumnfDATADDLinkLenLocal | read-only | current | Local FRM220-DATA card fiber D/D information: Link length |
| 1.3.6.1.4.1.4756.20.90.20.1.46 | ColumnfDATADDLenUnitLocal | read-only | current | Local FRM220-DATA card fiber D/D information: Length Unit |
| 1.3.6.1.4.1.4756.20.90.20.1.47 | ColumnfDATADDStatusLocal | read-only | current | Local FRM220-DATA card fiber D/D information: Status Support |
| 1.3.6.1.4.1.4756.20.90.20.1.48 | ColumnfDATADDRxSensLocal | read-only | current | Local FRM220-DATA card fiber D/D information: Rx Sensitivity |
| 1.3.6.1.4.1.4756.20.90.20.1.49 | ColumnfDATADDTxPwrLocal | read-only | current | Local FRM220-DATA card fiber D/D information: Tx power |
| 1.3.6.1.4.1.4756.20.90.20.1.50 | ColumnfDATADDRxPwrLocal | read-only | current | Local FRM220-DATA card fiber D/D information: Rx power |
| 1.3.6.1.4.1.4756.20.90.20.1.51 | ColumnfDATADDTempLocal | read-only | current | Local FRM220-DATA card fiber D/D information: Temperature in degree C |
| 1.3.6.1.4.1.4756.20.90.20.1.52 | ColumnfDATADDPwrMarginLocal | read-only | current | Local FRM220-DATA card fiber D/D information: Power margin |
| 1.3.6.1.4.1.4756.20.90.20.1.53 | ColumnfDATADDPwrLossLocal | read-only | current | Local FRM220-DATA card fiber D/D information: Power loss |
| 1.3.6.1.4.1.4756.20.91 | NodefDATARemoteCards | |||
| 1.3.6.1.4.1.4756.20.91.20 | TablefDATARemoteTable | not-accessible | current | A list of local FRM220-DATA card entries. The number of entries is fDATA-NoRemote. |
| 1.3.6.1.4.1.4756.20.91.20.1 | RowfDATARemoteEntry | not-accessible | current | An entry containing management information applicable to a particular local FRM220-DATA card. |
| 1.3.6.1.4.1.4756.20.91.20.1.1 | ColumnfDATAChassisIndexRemote | read-only | current | A unique value for each local card. It is the chassis location number. |
| 1.3.6.1.4.1.4756.20.91.20.1.2 | ColumnfDATASlotIndexRemote | read-only | current | A unique value for each local card. It is the slot location number. |
| 1.3.6.1.4.1.4756.20.91.20.1.3 | ColumnfDATACardHWVerRemote | read-only | current | Remote FRM220-DATA card hardware version x.xxx |
| 1.3.6.1.4.1.4756.20.91.20.1.4 | ColumnfDATACardFWVerRemote | read-only | current | Remote FRM220-DATA card firmware version x.xxx |
| 1.3.6.1.4.1.4756.20.91.20.1.5 | ColumnfDATACardCPLDVerRemote | read-only | current | Remote FRM220-DATA card CPLD version x.xxx |
| 1.3.6.1.4.1.4756.20.91.20.1.6 | ColumnfDATACardFPGAVerRemote | read-only | current | Remote FRM220-DATA card FPGA version x.xxx |
| 1.3.6.1.4.1.4756.20.91.20.1.7 | ColumnfDATAPortActiveRemote | read-only | current | Remote FRM220-DATA card active: 0:Inactive 1:Active |
| 1.3.6.1.4.1.4756.20.91.20.1.8 | ColumnfDATAFxLinkRemote | read-only | current | Remote FRM220-DATA fiber Link detected: 0:Link Down 1:Up |
| 1.3.6.1.4.1.4756.20.91.20.1.9 | ColumnfDATAFxSignalRemote | read-only | current | Local FRM220-DATA fiber signal detected: 0:No 1:Yes |
| 1.3.6.1.4.1.4756.20.91.20.1.10 | ColumnfDATAFxFEFRemote | read-only | current | Remote FRM220-DATA card fiber detected Far End Fault: 0:Off 1:Detected |
| 1.3.6.1.4.1.4756.20.91.20.1.11 | ColumnfDATAPortResetRemote | read-write | current | Force Remote FRM220-DATA card to reset mode: 0:Off 1:Action |
| 1.3.6.1.4.1.4756.20.91.20.1.12 | ColumnfDATASetDefaultRemote | read-write | current | Force Remote FRM220-DATA card to default status: 0:Off 1:Action |
| 1.3.6.1.4.1.4756.20.91.20.1.13 | ColumnfDATARdStateRemote | read-only | current | Remote FRM220-DATA card RD State: 0:on 1:off 2:flash |
| 1.3.6.1.4.1.4756.20.91.20.1.14 | ColumnfDATATdStateRemote | read-only | current | Remote FRM220-DATA card TD State: 0:on 1:off 2:flash |
| 1.3.6.1.4.1.4756.20.91.20.1.15 | ColumnfDATARtsStateRemote | read-only | current | Remote FRM220-DATA card RTS State: 0:on 1:off |
| 1.3.6.1.4.1.4756.20.91.20.1.16 | ColumnfDATACtsStateRemote | read-only | current | Remote FRM220-DATA card CTS State: 0:on 1:off |
| 1.3.6.1.4.1.4756.20.91.20.1.17 | ColumnfDATADcdStateRemote | read-only | current | Remote FRM220-DATA card DCD State: 0:on 1:off |
| 1.3.6.1.4.1.4756.20.91.20.1.18 | ColumnfDATAReDataRateGpRemote | read-write | current | Remote FRM220-DATA card Receive Data Rate Group Index Receive Data Rate Group Select 0 Group 1, N*64, N from 1 to 32, 64K~2048K 1 Group 2, N*64K, N from 33 to … |
| 1.3.6.1.4.1.4756.20.91.20.1.19 | ColumnfDATAReDataRateRemote | read-write | current | Remote FRM220-DATA card Receive Data Rate Index Receive Data Rate Select Group1 Group2 Group3 Group4 Group5 Group6 Group7 0 64K 2112K 4160K 6208K 8256K 75 Rese… |
| 1.3.6.1.4.1.4756.20.91.20.1.20 | ColumnfDATAReTimeSourceRemote | read-write | current | Remote FRM220-DATA card Receive Timing Source State 0:recovery from remote transmit side 1:internal 2:etc/rc input 3:recovery from remote receive side |
| 1.3.6.1.4.1.4756.20.91.20.1.21 | ColumnfDATATrDataRateGpRemote | read-write | current | Remote FRM220-DATA card Transmit Data Rate Group Index Transmit Data Rate Group Select 0 Group 1, N*64, N from 1 to 32, 64K~2048K 1 Group 2, N*64K, N from 33 t… |
| 1.3.6.1.4.1.4756.20.91.20.1.22 | ColumnfDATATrDataRateRemote | read-write | current | Remote FRM220-DATA card Transmit Data Rate Index Transmit Data Rate Select Group1 Group2 Group3 Group4 Group5 Group6 Group7 0 64K 2112K 4160K 6208K 8256K 75 Re… |
| 1.3.6.1.4.1.4756.20.91.20.1.23 | ColumnfDATATrTimeSourceRemote | read-write | current | Remote FRM220-DATA card Transmit Timing Source State 0:Same as Reveive Timing Source 1:internal 2:etc/rc input 3:recovery from remote receive side |
| 1.3.6.1.4.1.4756.20.91.20.1.24 | ColumnfDATADsrdtrRemote | read-write | current | Remote FRM220-DATA card DSR/DTR output setting 0:constantly on 1:follow local dtr/dsr input 2:follow remote dtr/dsr input |
| 1.3.6.1.4.1.4756.20.91.20.1.25 | ColumnfDATACtsrtsRemote | read-write | current | Remote FRM220-DATA card CTS/RTS output setting 0:constantly on 1:follow local cts/rts input 2:follow remote cts/rts input |
| 1.3.6.1.4.1.4756.20.91.20.1.26 | ColumnfDATAEtcRemote | read-write | current | Remote FRM220-DATA card ETC polarity setting 0:normal 1:invert |
| 1.3.6.1.4.1.4756.20.91.20.1.27 | ColumnfDATATcRemote | read-write | current | Remote FRM220-DATA card TC polarity setting 0:normal 1:invert |
| 1.3.6.1.4.1.4756.20.91.20.1.28 | ColumnfDATARcRemote | read-write | current | Remote FRM220-DATA card RC polarity setting 0:normal 1:invert |
| 1.3.6.1.4.1.4756.20.91.20.1.29 | ColumnfDATAAlsModeRemote | read-write | current | Remote FRM220-DATA card Auto Laser Shutdown mode: 0:Disable 1:Enable |
| 1.3.6.1.4.1.4756.20.91.20.1.30 | ColumnfDATADataPortModeRemote | read-write | current | Remote FRM220-DATA card Data Port Mode setting 0:DCE Mode 1:DTE Mode |
| 1.3.6.1.4.1.4756.20.91.20.1.31 | ColumnfDATADataPotrinterfaceRemote | read-write | current | Remote FRM220-DATA card Data Port Interface setting 0:rs530Remotes-449-x21 1:v35 2:rs-232 |
| 1.3.6.1.4.1.4756.20.91.20.1.32 | ColumnfDATALbsettingRemote | read-write | current | Remote FRM220-DATA card Loop Back Function & Select setting 0:off 5:data port side llb 6:data port side rlb 7:data port side rrlb |
| 1.3.6.1.4.1.4756.20.91.20.1.33 | ColumnfDATADcdoutsetRemote | read-write | current | Remote FRM220-DATA card DCD output setting 0:constantly on 1:follow remote dcd input |
| 1.3.6.1.4.1.4756.20.91.20.1.34 | ColumnfDATADsrStateRemote | read-only | current | Remote FRM220-DATA card DSR State 0:On 1:Off |
| 1.3.6.1.4.1.4756.20.91.20.1.35 | ColumnfDATADtrStateRemote | read-only | current | Remote FRM220-DATA card DTR State 0:On 1:Off |
| 1.3.6.1.4.1.4756.20.91.20.1.36 | ColumnfDATARlbStateRemote | read-only | current | Remote FRM220-DATA card RLB State 0:On 1:Off |
| 1.3.6.1.4.1.4756.20.91.20.1.37 | ColumnfDATALlbStateRemote | read-only | current | Remote FRM220-DATA card LLB State 0:On 1:Off |
| 1.3.6.1.4.1.4756.20.91.20.1.38 | ColumnfDATATmStateRemote | read-only | current | Remote FRM220-DATA card TM State 0:On 1:Off |
| 1.3.6.1.4.1.4756.20.91.20.1.39 | ColumnfDATAFxDDRemote | read-only | current | Remote FRM220-DATA card fiber Digital Diagnostic function: 0:No 1:Yes |
| 1.3.6.1.4.1.4756.20.91.20.1.40 | ColumnfDATADDVendorRemote | read-only | current | Remote FRM220-DATA card fiber D/D information: Vendor name |
| 1.3.6.1.4.1.4756.20.91.20.1.41 | ColumnfDATADDPartNoRemote | read-only | current | Remote FRM220-DATA card fiber D/D information: Vendor part number |
| 1.3.6.1.4.1.4756.20.91.20.1.42 | ColumnfDATADDFiberTypeRemote | read-only | current | Remote FRM220-DATA card fiber D/D information: Fiber Type |
| 1.3.6.1.4.1.4756.20.91.20.1.43 | ColumnfDATADDWaveLenRemote | read-only | current | Remote FRM220-DATA card fiber D/D information: Wave length |
| 1.3.6.1.4.1.4756.20.91.20.1.44 | ColumnfDATADDWaveLen2Remote | read-only | current | Remote FRM220-DATA card fiber D/D information: Wave length 2 |
| 1.3.6.1.4.1.4756.20.91.20.1.45 | ColumnfDATADDLinkLenRemote | read-only | current | Remote FRM220-DATA card fiber D/D information: Link length |
| 1.3.6.1.4.1.4756.20.91.20.1.46 | ColumnfDATADDLenUnitRemote | read-only | current | Remote FRM220-DATA card fiber D/D information: Length Unit |
| 1.3.6.1.4.1.4756.20.91.20.1.47 | ColumnfDATADDStatusRemote | read-only | current | Remote FRM220-DATA card fiber D/D information: Status Support |
| 1.3.6.1.4.1.4756.20.91.20.1.48 | ColumnfDATADDRxSensRemote | read-only | current | Remote FRM220-DATA card fiber D/D information: Rx Sensitivity |
| 1.3.6.1.4.1.4756.20.91.20.1.49 | ColumnfDATADDTxPwrRemote | read-only | current | Remote FRM220-DATA card fiber D/D information: Tx power |
| 1.3.6.1.4.1.4756.20.91.20.1.50 | ColumnfDATADDRxPwrRemote | read-only | current | Remote FRM220-DATA card fiber D/D information: Rx power |
| 1.3.6.1.4.1.4756.20.91.20.1.51 | ColumnfDATADDTempRemote | read-only | current | Remote FRM220-DATA card fiber D/D information: Temperature in degree C |
| 1.3.6.1.4.1.4756.20.91.20.1.52 | ColumnfDATADDPwrMarginRemote | read-only | current | Remote FRM220-DATA card fiber D/D information: Power margin |
| 1.3.6.1.4.1.4756.20.91.20.1.53 | ColumnfDATADDPwrLossRemote | read-only | current | Remote FRM220-DATA card fiber D/D information: Power loss |
| 1.3.6.1.4.1.4756.20.100 | NodefE1T1LocalCards | |||
| 1.3.6.1.4.1.4756.20.100.20 | TablefE1T1LocalTable | not-accessible | current | A list of local FRM220-DATA card entries. The number of entries is fE1T1-No-L. |
| 1.3.6.1.4.1.4756.20.100.20.1 | RowfE1T1LocalEntry | not-accessible | current | An entry containing management information applicable to a particular local FRM220-E1T1 card. |
| 1.3.6.1.4.1.4756.20.100.20.1.1 | ColumnfE1T1ChassisIndexLocal | read-only | current | A unique value for each local card. It is the chassis location number. |
| 1.3.6.1.4.1.4756.20.100.20.1.2 | ColumnfE1T1SlotIndexLocal | read-only | current | A unique value for each local card. It is the slot location number. |
| 1.3.6.1.4.1.4756.20.100.20.1.3 | ColumnfE1T1CardHWVerLocal | read-only | current | Local FRM220-E1/T1 card hardware version x.xxx |
| 1.3.6.1.4.1.4756.20.100.20.1.4 | ColumnfE1T1CardFWVerLocal | read-only | current | Local FRM220-E1/T1 card firmware version x.xxx |
| 1.3.6.1.4.1.4756.20.100.20.1.5 | ColumnfE1T1CardCPLDVerLocal | read-only | current | Local FRM220-E1/T1 card CPLD version x.xxx |
| 1.3.6.1.4.1.4756.20.100.20.1.6 | ColumnfE1T1CardFPGAVerLocal | read-only | current | Local FRM220-E1/T1 card FPGA version x.xxx |
| 1.3.6.1.4.1.4756.20.100.20.1.7 | ColumnfE1T1PortActiveLocal | read-write | current | Local FRM220-E1/T1 card active: 0:Inactive 1:Active |
| 1.3.6.1.4.1.4756.20.100.20.1.8 | ColumnfE1T1SignalLocal | read-only | current | Local FRM220-E1/T1 card active: 0:signal-loss 1:normal |
| 1.3.6.1.4.1.4756.20.100.20.1.9 | ColumnfE1T1SyncLocal | read-only | current | Local FRM220-E1/T1 card active: 0:sync-loss 1:sync |
| 1.3.6.1.4.1.4756.20.100.20.1.10 | ColumnfE1T1ReAISLocal | read-only | current | Local FRM220-E1/T1 card active: 0:no 1:yes |
| 1.3.6.1.4.1.4756.20.100.20.1.11 | ColumnfE1T1ConTypeLocal | read-only | current | Local FRM220-E1/T1 card active: 0:rj-48c 1:bnc |
| 1.3.6.1.4.1.4756.20.100.20.1.12 | ColumnfE1T1FxLinkLocal | read-only | current | Local FRM220-E1/T1 fiber Link detected: 0:Link Down 1:Up |
| 1.3.6.1.4.1.4756.20.100.20.1.13 | ColumnfE1T1FxSignalLocal | read-only | current | Local FRM220-E1/T1 fiber signal detected: 0:No 1:Yes |
| 1.3.6.1.4.1.4756.20.100.20.1.14 | ColumnfE1T1FxFEFLocal | read-only | current | Local FRM220-E1/T1 card fiber detected Far End Fault: 0:Off 1:Detected |
| 1.3.6.1.4.1.4756.20.100.20.1.15 | ColumnfE1T1PortResetLocal | read-write | current | Force local FRM220-E1/T1 card to reset mode: 0:Off 1:Action |
| 1.3.6.1.4.1.4756.20.100.20.1.16 | ColumnfE1T1SetDefaultLocal | read-write | current | Force local FRM220-E1/T1 card to default status: 0:Off 1:Action |
| 1.3.6.1.4.1.4756.20.100.20.1.17 | ColumnfE1T1E1T1selLocal | read-write | current | Local FRM220-E1/T1 card E1/T1 Select: 0:e1 1:t1 |
| 1.3.6.1.4.1.4756.20.100.20.1.18 | ColumnfE1T1LineCodeLocal | read-write | current | Local FRM220-E1/T1 card E1/T1 Line Code setting: 0:hdb3-b8zs 1:ami |
| 1.3.6.1.4.1.4756.20.100.20.1.19 | ColumnfE1T1FullFractionalLocal | read-write | current | Local FRM220-E1/T1 card E1/T1 Full/Fractional: 0:full-e1t1 1:fraction-e1t1 |
| 1.3.6.1.4.1.4756.20.100.20.1.20 | ColumnfE1T1FramerLocal | read-write | current | Local FRM220-E1/T1 card E1/T1 Framer setting: 0:ccs-d4 1:cas-esf |
| 1.3.6.1.4.1.4756.20.100.20.1.21 | ColumnfE1T1CrcLocal | read-write | current | Local FRM220-E1/T1 card CRC setting: 0:disable 1:enable |
| 1.3.6.1.4.1.4756.20.100.20.1.22 | ColumnfE1T1RelossTraisLocal | read-write | current | Local FRM220-E1/T1 card Receive loss transmit AIS: 0:disable 1:enable |
| 1.3.6.1.4.1.4756.20.100.20.1.23 | ColumnfE1T1UnusedTimeslotCodeLocal | read-write | current | Local FRM220-E1/T1 card Unused timeslot code setting: 0:0x7e 1:0xff |
| 1.3.6.1.4.1.4756.20.100.20.1.24 | ColumnfE1T1TrtimesourceLocal | read-write | current | Local FRM220-E1/T1 card Timing Source: 0:recovery from remote transmit side 1:recovery-from-e1t1 Receive 2:internal-oscillator 3:reserve |
| 1.3.6.1.4.1.4756.20.100.20.1.25 | ColumnfE1T1AlsLocal | read-write | current | Local FRM220-E1/T1 card Auto Laser Shutdown: 0:disable 1:enable |
| 1.3.6.1.4.1.4756.20.100.20.1.26 | ColumnfE1T1RateLocal | read-write | current | Local FRM220-E1/T1 card Active Timeslot Numbers: E1 : CCS Mode CAS Mode T1: 1 64K 64K 64K 2 128K 128K 128K 3 192K 192K 192K 4 256K 256K 256K 5 320K 320K 320K 6… |
| 1.3.6.1.4.1.4756.20.100.20.1.27 | ColumnfE1T1TimeslotLocal | read-write | current | Local FRM220-E1/T1 card Start Timeslot: |
| 1.3.6.1.4.1.4756.20.100.20.1.28 | ColumnfE1T1LbsettingLocal | read-write | current | Local FRM220-E1/T1 card Loop Back setting: 0:off 1:fiber-side-llb 2:fiber-side-rlb 3:fiber-side-rrlb 5:e1t1-port-side-llb 6:e1t1-port-side-rlb 7:e1t1-port-side… |
| 1.3.6.1.4.1.4756.20.100.20.1.29 | ColumnfE1T1RdstateLocal | read-only | current | Local FRM220-E1/T1 card RD state: 0:on 1:off 2:flash |
| 1.3.6.1.4.1.4756.20.100.20.1.30 | ColumnfE1T1TdstateLocal | read-only | current | Local FRM220-E1/T1 card TD state: 0:on 1:off 2:flash |
| 1.3.6.1.4.1.4756.20.100.20.1.31 | ColumnfE1T1TeststateLocal | read-only | current | Local FRM220-E1/T1 card Test mode: 0:normal 1:at-test-mode |
| 1.3.6.1.4.1.4756.20.100.20.1.32 | ColumnfE1T1FxDDLocal | read-only | current | Local FRM220-E1/T1 card fiber Digital Diagnostic function: 0:No 1:Yes |
| 1.3.6.1.4.1.4756.20.100.20.1.33 | ColumnfE1T1DDVendorLocal | read-only | current | Local FRM220-E1/T1 card fiber D/D information: Vendor name |
| 1.3.6.1.4.1.4756.20.100.20.1.34 | ColumnfE1T1DDPartNoLocal | read-only | current | Local FRM220-E1/T1 card fiber D/D information: Vendor part number |
| 1.3.6.1.4.1.4756.20.100.20.1.35 | ColumnfE1T1DDFiberTypeLocal | read-only | current | Local FRM220-E1/T1 card fiber D/D information: Fiber Type |
| 1.3.6.1.4.1.4756.20.100.20.1.36 | ColumnfE1T1DDWaveLenLocal | read-only | current | Local FRM220-E1/T1 card fiber D/D information: Wave length |
| 1.3.6.1.4.1.4756.20.100.20.1.37 | ColumnfE1T1DDWaveLen2Local | read-only | current | Local FRM220-E1/T1 card fiber D/D information: Wave length 2 |
| 1.3.6.1.4.1.4756.20.100.20.1.38 | ColumnfE1T1DDLinkLenLocal | read-only | current | Local FRM220-E1/T1 card fiber D/D information: Link length |
| 1.3.6.1.4.1.4756.20.100.20.1.39 | ColumnfE1T1DDLenUnitLocal | read-only | current | Local FRM220-E1/T1 card fiber D/D information: Length Unit |
| 1.3.6.1.4.1.4756.20.100.20.1.40 | ColumnfE1T1DDStatusLocal | read-only | current | Local FRM220-E1/T1 card fiber D/D information: Status Support |
| 1.3.6.1.4.1.4756.20.100.20.1.41 | ColumnfE1T1DDRxSensLocal | read-only | current | Local FRM220-E1/T1 card fiber D/D information: Rx Sensitivity |
| 1.3.6.1.4.1.4756.20.100.20.1.42 | ColumnfE1T1DDTxPwrLocal | read-only | current | Local FRM220-E1/T1 card fiber D/D information: Tx power |
| 1.3.6.1.4.1.4756.20.100.20.1.43 | ColumnfE1T1DDRxPwrLocal | read-only | current | Local FRM220-E1/T1 card fiber D/D information: Rx power |
| 1.3.6.1.4.1.4756.20.100.20.1.44 | ColumnfE1T1DDTempLocal | read-only | current | Local FRM220-E1/T1 card fiber D/D information: Temperature in degree C |
| 1.3.6.1.4.1.4756.20.100.20.1.45 | ColumnfE1T1DDPwrMarginLocal | read-only | current | Local FRM220-E1/T1 card fiber D/D information: Power margin |
| 1.3.6.1.4.1.4756.20.100.20.1.46 | ColumnfE1T1DDPwrLossLocal | read-only | current | Local FRM220-E1/T1 card fiber D/D information: Power loss |
| 1.3.6.1.4.1.4756.20.100.20.1.47 | ColumnfE1T1FxLinkAlarmLocal | read-write | current | Local FRM220-E1/T1 card fiber link alarm 0:Disable 1:Enable |
| 1.3.6.1.4.1.4756.20.100.20.1.48 | ColumnfE1T1LinkAlarmLocal | read-write | current | Local FRM220-E1/T1 card E1T1 link alarm 0:Disable 1:Enable |
| 1.3.6.1.4.1.4756.20.101 | NodefE1T1remoteCards | |||
| 1.3.6.1.4.1.4756.20.101.20 | TablefE1T1RemoteTable | not-accessible | current | A list of local FRM220-E1/T1 card entries. The number of entries is fE1T1-NoRemote. |
| 1.3.6.1.4.1.4756.20.101.20.1 | RowfE1T1RemoteEntry | not-accessible | current | An entry containing management information applicable to a particular local FRM220-E1T1 card. |
| 1.3.6.1.4.1.4756.20.101.20.1.1 | ColumnfE1T1ChassisIndexRemote | read-only | current | A unique value for each Remote card. It is the chassis location number. |
| 1.3.6.1.4.1.4756.20.101.20.1.2 | ColumnfE1T1SlotIndexRemote | read-only | current | A unique value for each Remote card. It is the slot location number. |
| 1.3.6.1.4.1.4756.20.101.20.1.3 | ColumnfE1T1CardHWVerRemote | read-only | current | Remote FRM220-E1/T1 card hardware version x.xxx |
| 1.3.6.1.4.1.4756.20.101.20.1.4 | ColumnfE1T1CardFWVerRemote | read-only | current | Remote FRM220-E1/T1 card firmware version x.xxx |
| 1.3.6.1.4.1.4756.20.101.20.1.5 | ColumnfE1T1CardCPLDVerRemote | read-only | current | Remote FRM220-E1/T1 card CPLD version x.xxx |
| 1.3.6.1.4.1.4756.20.101.20.1.6 | ColumnfE1T1CardFPGAVerRemote | read-only | current | Remote FRM220-E1/T1 card FPGA version x.xxx |
| 1.3.6.1.4.1.4756.20.101.20.1.7 | ColumnfE1T1PortActiveRemote | read-only | current | Remote FRM220-E1/T1 card active: 0:Inactive 1:Active |
| 1.3.6.1.4.1.4756.20.101.20.1.8 | ColumnfE1T1SignalRemote | read-only | current | Remote FRM220-E1/T1 card active: 0:signal-loss 1:normal |
| 1.3.6.1.4.1.4756.20.101.20.1.9 | ColumnfE1T1SyncRemote | read-only | current | Remote FRM220-E1/T1 card active: 0:sync-loss 1:sync |
| 1.3.6.1.4.1.4756.20.101.20.1.10 | ColumnfE1T1ReAISRemote | read-only | current | Remote FRM220-E1/T1 card active: 0:no 1:yes |
| 1.3.6.1.4.1.4756.20.101.20.1.11 | ColumnfE1T1ConTypeRemote | read-only | current | Remote FRM220-E1/T1 card active: 0:rj-48c 1:bnc |
| 1.3.6.1.4.1.4756.20.101.20.1.12 | ColumnfE1T1FxLinkRemote | read-only | current | Remote FRM220-E1/T1 fiber Link detected: 0:Link Down 1:Up |
| 1.3.6.1.4.1.4756.20.101.20.1.13 | ColumnfE1T1FxSignalRemote | read-only | current | Remote FRM220-E1/T1 fiber signal detected: 0:No 1:Yes |
| 1.3.6.1.4.1.4756.20.101.20.1.14 | ColumnfE1T1FxFEFRemote | read-only | current | Remote FRM220-E1/T1 card fiber detected Far End Fault: 0:Off 1:Detected |
| 1.3.6.1.4.1.4756.20.101.20.1.15 | ColumnfE1T1PortResetRemote | read-write | current | Force Remote FRM220-E1/T1 card to reset mode: 0:Off 1:Action |
| 1.3.6.1.4.1.4756.20.101.20.1.16 | ColumnfE1T1SetDefaultRemote | read-write | current | Force Remote FRM220-E1/T1 card to default status: 0:Off 1:Action |
| 1.3.6.1.4.1.4756.20.101.20.1.17 | ColumnfE1T1E1T1selRemote | read-write | current | Remote FRM220-E1/T1 card E1/T1 Select: 0:e1 1:t1 |
| 1.3.6.1.4.1.4756.20.101.20.1.18 | ColumnfE1T1LineCodeRemote | read-write | current | Remote FRM220-E1/T1 card E1/T1 Line Code setting: 0:hdb3-b8zs 1:ami |
| 1.3.6.1.4.1.4756.20.101.20.1.19 | ColumnfE1T1FullFractionalRemote | read-write | current | Remote FRM220-E1/T1 card E1/T1 Full/Fractional: 0:full-e1t1 1:fraction-e1t1 |
| 1.3.6.1.4.1.4756.20.101.20.1.20 | ColumnfE1T1FramerRemote | read-write | current | Remote FRM220-E1/T1 card E1/T1 Framer setting: 0:ccs-d4 1:cas-esf |
| 1.3.6.1.4.1.4756.20.101.20.1.21 | ColumnfE1T1CrcRemote | read-write | current | Remote FRM220-E1/T1 card CRC setting: 0:disable 1:enable |
| 1.3.6.1.4.1.4756.20.101.20.1.22 | ColumnfE1T1RelossTraisRemote | read-write | current | Remote FRM220-E1/T1 card Receive loss transmit AIS: 0:disable 1:enable |
| 1.3.6.1.4.1.4756.20.101.20.1.23 | ColumnfE1T1UnusedTimeslotCodeRemote | read-write | current | Remote FRM220-E1/T1 card Unused timeslot code setting: 0:0x7e 1:0xff |
| 1.3.6.1.4.1.4756.20.101.20.1.24 | ColumnfE1T1TrtimesourceRemote | read-write | current | Remote FRM220-E1/T1 card Timing Source: 0:recovery from remote transmit side 1:recovery-from-e1t1 Receive 2:internal-oscillator 3:reserve |
| 1.3.6.1.4.1.4756.20.101.20.1.25 | ColumnfE1T1AlsRemote | read-write | current | Remote FRM220-E1/T1 card Auto Laser Shutdown: 0:disable 1:enable |
| 1.3.6.1.4.1.4756.20.101.20.1.26 | ColumnfE1T1RateRemote | read-write | current | Remote FRM220-E1/T1 card Active Timeslot Numbers: E1 : CCS Mode CAS Mode T1: 1 64K 64K 64K 2 128K 128K 128K 3 192K 192K 192K 4 256K 256K 256K 5 320K 320K 320K … |
| 1.3.6.1.4.1.4756.20.101.20.1.27 | ColumnfE1T1TimeslotRemote | read-write | current | Remote FRM220-E1/T1 card Start Timeslot: |
| 1.3.6.1.4.1.4756.20.101.20.1.28 | ColumnfE1T1LbsettingRemote | read-write | current | Remote FRM220-E1/T1 card Loop Back setting: 0:off 5:e1t1-port-side-llb 6:e1t1-port-side-rlb 7:e1t1-port-side-rrlb |
| 1.3.6.1.4.1.4756.20.101.20.1.29 | ColumnfE1T1RdstateRemote | read-only | current | Remote FRM220-E1/T1 card RD state: 0:on 1:off 2:flash |
| 1.3.6.1.4.1.4756.20.101.20.1.30 | ColumnfE1T1TdstateRemote | read-only | current | Remote FRM220-E1/T1 card TD state: 0:on 1:off 2:flash |
| 1.3.6.1.4.1.4756.20.101.20.1.31 | ColumnfE1T1TeststateRemote | read-only | current | Remote FRM220-E1/T1 card Test mode: 0:normal 1:at-test-mode |
| 1.3.6.1.4.1.4756.20.101.20.1.32 | ColumnfE1T1FxDDRemote | read-only | current | Remote FRM220-E1/T1 card fiber Digital Diagnostic function: 0:No 1:Yes |
| 1.3.6.1.4.1.4756.20.101.20.1.33 | ColumnfE1T1DDVendorRemote | read-only | current | Remote FRM220-E1/T1 card fiber D/D information: Vendor name |
| 1.3.6.1.4.1.4756.20.101.20.1.34 | ColumnfE1T1DDPartNoRemote | read-only | current | Remote FRM220-E1/T1 card fiber D/D information: Vendor part number |
| 1.3.6.1.4.1.4756.20.101.20.1.35 | ColumnfE1T1DDFiberTypeRemote | read-only | current | Remote FRM220-E1/T1 card fiber D/D information: Fiber Type |
| 1.3.6.1.4.1.4756.20.101.20.1.36 | ColumnfE1T1DDWaveLenRemote | read-only | current | Remote FRM220-E1/T1 card fiber D/D information: Wave length |
| 1.3.6.1.4.1.4756.20.101.20.1.37 | ColumnfE1T1DDWaveLen2Remote | read-only | current | Remote FRM220-E1/T1 card fiber D/D information: Wave length 2 |
| 1.3.6.1.4.1.4756.20.101.20.1.38 | ColumnfE1T1DDLinkLenRemote | read-only | current | Remote FRM220-E1/T1 card fiber D/D information: Link length |
| 1.3.6.1.4.1.4756.20.101.20.1.39 | ColumnfE1T1DDLenUnitRemote | read-only | current | Remote FRM220-E1/T1 card fiber D/D information: Length Unit |
| 1.3.6.1.4.1.4756.20.101.20.1.40 | ColumnfE1T1DDStatusRemote | read-only | current | Remote FRM220-E1/T1 card fiber D/D information: Status Support |
| 1.3.6.1.4.1.4756.20.101.20.1.41 | ColumnfE1T1DDRxSensRemote | read-only | current | Remote FRM220-E1/T1 card fiber D/D information: Rx Sensitivity |
| 1.3.6.1.4.1.4756.20.101.20.1.42 | ColumnfE1T1DDTxPwrRemote | read-only | current | Remote FRM220-E1/T1 card fiber D/D information: Tx power |
| 1.3.6.1.4.1.4756.20.101.20.1.43 | ColumnfE1T1DDRxPwrRemote | read-only | current | Remote FRM220-E1/T1 card fiber D/D information: Rx power |
| 1.3.6.1.4.1.4756.20.101.20.1.44 | ColumnfE1T1DDTempRemote | read-only | current | Remote FRM220-E1/T1 card fiber D/D information: Temperature in degree C |
| 1.3.6.1.4.1.4756.20.101.20.1.45 | ColumnfE1T1DDPwrMarginRemote | read-only | current | Remote FRM220-E1/T1 card fiber D/D information: Power margin |
| 1.3.6.1.4.1.4756.20.101.20.1.46 | ColumnfE1T1DDPwrLossRemote | read-only | current | Remote FRM220-E1/T1 card fiber D/D information: Power loss |
| 1.3.6.1.4.1.4756.20.101.20.1.47 | ColumnfE1T1FxLinkAlarmRemote | read-write | current | Remote FRM220-E1/T1 card fiber link alarm 0:Disable 1:Enable |
| 1.3.6.1.4.1.4756.20.101.20.1.48 | ColumnfE1T1LinkAlarmRemote | read-write | current | Remote FRM220-E1/T1 card E1T1 link alarm 0:Disable 1:Enable |
| 1.3.6.1.4.1.4756.20.110 | Nodef5E1LocalCards | |||
| 1.3.6.1.4.1.4756.20.110.20 | Tablef5E1LocalTable | not-accessible | current | A list of local FRM220-5E1-ET100 series card entries. The number of entries is f5E1-No-L. |
| 1.3.6.1.4.1.4756.20.110.20.1 | Rowf5E1LocalEntry | not-accessible | current | An entry containing management information applicable to a particular local FRM220-5E1 series card. |
| 1.3.6.1.4.1.4756.20.110.20.1.1 | Columnfa5e1et100ChassisIndexLocal | read-only | current | A unique value for each card. It starts from 0 to 9 contiguously. |
| 1.3.6.1.4.1.4756.20.110.20.1.2 | Columnfa5e1et100SlotIndexLocal | read-only | current | A unique value for each card. It starts from 1 to 20 contiguously. |
| 1.3.6.1.4.1.4756.20.110.20.1.3 | Columnfa5e1et100CardHWVerLocal | read-only | current | 5E1-ET100(T/S) Series card hardware version x.xxx |
| 1.3.6.1.4.1.4756.20.110.20.1.4 | Columnfa5e1et100CardFWVerLocal | read-only | current | 5E1-ET100(T/S) Series card firmware version x.xxx |
| 1.3.6.1.4.1.4756.20.110.20.1.5 | Columnfa5e1et100CardCPLDVerLocal | read-only | current | 5E1-ET100(T/S) Series card CPLD version x.xxx |
| 1.3.6.1.4.1.4756.20.110.20.1.6 | Columnfa5e1et100CardFPGAVerLocal | read-only | current | 5E1-ET100(T/S) Series card FPGA version x.xxx |
| 1.3.6.1.4.1.4756.20.110.20.1.7 | Columnfa5e1et100ModelLocal | read-only | current | Card Type: 0:5E1-ET100T 1:5E1-ET100S |
| 1.3.6.1.4.1.4756.20.110.20.1.8 | Columnfa5e1et100SystemStatusLocal | read-only | current | 5E1-ET100(T/S) Series card system status: 0:Normal 1:Alarm |
| 1.3.6.1.4.1.4756.20.110.20.1.9 | Columnfa5e1et100DeviceActiveLocal | read-write | current | 5E1-ET100(T/S) Series card active: 0:Disable 1:Enable |
| 1.3.6.1.4.1.4756.20.110.20.1.10 | Columnfa5e1et100SetToDefaultLocal | read-write | current | 5E1-ET100(T/S) Series card port set to default: 0:Off 1:Trigger |
| 1.3.6.1.4.1.4756.20.110.20.1.11 | Columnfa5e1et100E1Ch1SingalLocal | read-only | current | 5E1-ET100(T/S) Series card E1 channel 1 signal status: 0:Singal Loss 1:Normal |
| 1.3.6.1.4.1.4756.20.110.20.1.12 | Columnfa5e1et100E1Ch2SingalLocal | read-only | current | 5E1-ET100(T/S) Series card E1 channel 2 signal status: 0:Singal Loss 1:Normal |
| 1.3.6.1.4.1.4756.20.110.20.1.13 | Columnfa5e1et100E1Ch3SingalLocal | read-only | current | 5E1-ET100(T/S) Series card E1 channel 3 signal status: 0:Singal Loss 1:Normal |
| 1.3.6.1.4.1.4756.20.110.20.1.14 | Columnfa5e1et100E1Ch4SingalLocal | read-only | current | 5E1-ET100(T/S) Series card E1 channel 4 signal status: 0:Singal Loss 1:Normal |
| 1.3.6.1.4.1.4756.20.110.20.1.15 | Columnfa5e1et100E1Ch5SingalLocal | read-only | current | 5E1-ET100(T/S) Series card E1 channel 5 signal status: 0:Singal Loss 1:Normal |
| 1.3.6.1.4.1.4756.20.110.20.1.16 | Columnfa5e1et100E1Ch1SyncLocal | read-only | current | 5E1-ET100(T/S) Series card E1 channel 1 sync status: 0:Sync Loss 1:Sync |
| 1.3.6.1.4.1.4756.20.110.20.1.17 | Columnfa5e1et100E1Ch2SyncLocal | read-only | current | 5E1-ET100(T/S) Series card E1 channel 2 sync status: 0:Sync Loss 1:Sync |
| 1.3.6.1.4.1.4756.20.110.20.1.18 | Columnfa5e1et100E1Ch3SyncLocal | read-only | current | 5E1-ET100(T/S) Series card E1 channel 3 sync status: 0:Sync Loss 1:Sync |
| 1.3.6.1.4.1.4756.20.110.20.1.19 | Columnfa5e1et100E1Ch4SyncLocal | read-only | current | 5E1-ET100(T/S) Series card E1 channel 4 sync status: 0:Sync Loss 1:Sync |
| 1.3.6.1.4.1.4756.20.110.20.1.20 | Columnfa5e1et100E1Ch5SyncLocal | read-only | current | 5E1-ET100(T/S) Series card E1 channel 5 sync status: 0:Sync Loss 1:Sync |
| 1.3.6.1.4.1.4756.20.110.20.1.21 | Columnfa5e1et100E1Ch1RecvAISLocal | read-only | current | 5E1-ET100(T/S) Series card E1 channel 1 receive AIS status: 0:No 1:Yes |
| 1.3.6.1.4.1.4756.20.110.20.1.22 | Columnfa5e1et100E1Ch2RecvAISLocal | read-only | current | 5E1-ET100(T/S) Series card E1 channel 2 receive AIS status: 0:No 1:Yes |
| 1.3.6.1.4.1.4756.20.110.20.1.23 | Columnfa5e1et100E1Ch3RecvAISLocal | read-only | current | 5E1-ET100(T/S) Series card E1 channel 3 receive AIS status: 0:No 1:Yes |
| 1.3.6.1.4.1.4756.20.110.20.1.24 | Columnfa5e1et100E1Ch4RecvAISLocal | read-only | current | 5E1-ET100(T/S) Series card E1 channel 4 receive AIS status: 0:No 1:Yes |
| 1.3.6.1.4.1.4756.20.110.20.1.25 | Columnfa5e1et100E1Ch5RecvAISLocal | read-only | current | 5E1-ET100(T/S) Series card E1 channel 5 receive AIS status: 0:No 1:Yes |
| 1.3.6.1.4.1.4756.20.110.20.1.26 | Columnfa5e1et100E1Ch1ConnTypeLocal | read-only | current | 5E1-ET100(T/S) Series card E1 channel 1 connector type: 0:RJ-48C 1:BNC |
| 1.3.6.1.4.1.4756.20.110.20.1.27 | Columnfa5e1et100E1Ch2ConnTypeLocal | read-only | current | 5E1-ET100(T/S) Series card E1 channel 2 connector type: 0:RJ-48C 1:BNC |
| 1.3.6.1.4.1.4756.20.110.20.1.28 | Columnfa5e1et100E1Ch3ConnTypeLocal | read-only | current | 5E1-ET100(T/S) Series card E1 channel 3 connector type: 0:RJ-48C 1:BNC |
| 1.3.6.1.4.1.4756.20.110.20.1.29 | Columnfa5e1et100E1Ch4ConnTypeLocal | read-only | current | 5E1-ET100(T/S) Series card E1 channel 4 connector type: 0:RJ-48C 1:BNC |
| 1.3.6.1.4.1.4756.20.110.20.1.30 | Columnfa5e1et100E1Ch5ConnTypeLocal | read-only | current | 5E1-ET100(T/S) Series card E1 channel 5 connector type: 0:RJ-48C 1:BNC |
| 1.3.6.1.4.1.4756.20.110.20.1.31 | Columnfa5e1et100E1Ch1RAILocal | read-only | current | 5E1-ET100(T/S) Series card E1 channel 1 RAI status: 0:No 1:Yes |
| 1.3.6.1.4.1.4756.20.110.20.1.32 | Columnfa5e1et100E1Ch2RAILocal | read-only | current | 5E1-ET100(T/S) Series card E1 channel 2 RAI status: 0:No 1:Yes |
| 1.3.6.1.4.1.4756.20.110.20.1.33 | Columnfa5e1et100E1Ch3RAILocal | read-only | current | 5E1-ET100(T/S) Series card E1 channel 3 RAI status: 0:No 1:Yes |
| 1.3.6.1.4.1.4756.20.110.20.1.34 | Columnfa5e1et100E1Ch4RAILocal | read-only | current | 5E1-ET100(T/S) Series card E1 channel 4 RAI status: 0:No 1:Yes |
| 1.3.6.1.4.1.4756.20.110.20.1.35 | Columnfa5e1et100E1Ch5RAILocal | read-only | current | 5E1-ET100(T/S) Series card E1 channel 5 RAI status: 0:No 1:Yes |
| 1.3.6.1.4.1.4756.20.110.20.1.36 | Columnfa5e1et100E1Ch1LOMFLocal | read-only | current | 5E1-ET100(T/S) Series card E1 channel 1 LOMF status: 0:No 1:Yes |
| 1.3.6.1.4.1.4756.20.110.20.1.37 | Columnfa5e1et100E1Ch2LOMFLocal | read-only | current | 5E1-ET100(T/S) Series card E1 channel 2 LOMF status: 0:No 1:Yes |
| 1.3.6.1.4.1.4756.20.110.20.1.38 | Columnfa5e1et100E1Ch3LOMFLocal | read-only | current | 5E1-ET100(T/S) Series card E1 channel 3 LOMF status: 0:No 1:Yes |
| 1.3.6.1.4.1.4756.20.110.20.1.39 | Columnfa5e1et100E1Ch4LOMFLocal | read-only | current | 5E1-ET100(T/S) Series card E1 channel 4 LOMF status: 0:No 1:Yes |
| 1.3.6.1.4.1.4756.20.110.20.1.40 | Columnfa5e1et100E1Ch5LOMFLocal | read-only | current | 5E1-ET100(T/S) Series card E1 channel 5 LOMF status: 0:No 1:Yes |
| 1.3.6.1.4.1.4756.20.110.20.1.41 | Columnfa5e1et100E1Ch1ActiveLocal | read-only | current | 5E1-ET100(T/S) Series card E1 channel 1 active status: 0:Inactive 1:Active |
| 1.3.6.1.4.1.4756.20.110.20.1.42 | Columnfa5e1et100E1Ch2ActiveLocal | read-only | current | 5E1-ET100(T/S) Series card E1 channel 2 active status: 0:Inactive 1:Active |
| 1.3.6.1.4.1.4756.20.110.20.1.43 | Columnfa5e1et100E1Ch3ActiveLocal | read-only | current | 5E1-ET100(T/S) Series card E1 channel 3 active status: 0:Inactive 1:Active |
| 1.3.6.1.4.1.4756.20.110.20.1.44 | Columnfa5e1et100E1Ch4ActiveLocal | read-only | current | 5E1-ET100(T/S) Series card E1 channel 4 active status: 0:Inactive 1:Active |
| 1.3.6.1.4.1.4756.20.110.20.1.45 | Columnfa5e1et100E1Ch5ActiveLocal | read-only | current | 5E1-ET100(T/S) Series card E1 channel 5 active status: 0:Inactive 1:Active |
| 1.3.6.1.4.1.4756.20.110.20.1.46 | Columnfa5e1et100E1Ch1LoopBackLocal | read-write | current | 5E1-ET100(T/S) Series card port E1 channel 1 loop back: 0:Off 2:RLB (Max used 4 channels) |
| 1.3.6.1.4.1.4756.20.110.20.1.47 | Columnfa5e1et100E1Ch2LoopBackLocal | read-write | current | 5E1-ET100(T/S) Series card port E1 channel 2 loop back: 0:Off 2:RLB (Max used 4 channels) |
| 1.3.6.1.4.1.4756.20.110.20.1.48 | Columnfa5e1et100E1Ch3LoopBackLocal | read-write | current | 5E1-ET100(T/S) Series card port E1 channel 3 loop back: 0:Off 2:RLB (Max used 4 channels) |
| 1.3.6.1.4.1.4756.20.110.20.1.49 | Columnfa5e1et100E1Ch4LoopBackLocal | read-write | current | 5E1-ET100(T/S) Series card port E1 channel 4 loop back: 0:Off 2:RLB (Max used 4 channels) |
| 1.3.6.1.4.1.4756.20.110.20.1.50 | Columnfa5e1et100E1Ch5LoopBackLocal | read-write | current | 5E1-ET100(T/S) Series card port E1 channel 5 loop back: 0:Off 2:RLB (Max used 4 channels) |
| 1.3.6.1.4.1.4756.20.110.20.1.51 | Columnfa5e1et100FxLinkLocal | read-only | current | 5E1-ET100S Series card Fiber siganl detect status: 0:Down or Fiber unplugged 1:Up or Singal detected |
| 1.3.6.1.4.1.4756.20.110.20.1.52 | Columnfa5e1et100FxLaserLocal | read-only | current | 5E1-ET100S Series card laser status: 0:Normal 1:Error |
| 1.3.6.1.4.1.4756.20.110.20.1.53 | Columnfa5e1et100FxActiveLocal | read-write | current | 5E1-ET100S Series card Fiber active: 0:Inactive 1:Active |
| 1.3.6.1.4.1.4756.20.110.20.1.54 | Columnfa5e1et100FxLaserOutputLocal | read-write | current | 5E1-ET100S Series card laser output: 0:disable 1:Enable |
| 1.3.6.1.4.1.4756.20.110.20.1.55 | Columnfa5e1et100FxOpModeLocal | read-write | current | 5E1-ET100S Series card operation mode: 0:Switch 1:Convert |
| 1.3.6.1.4.1.4756.20.110.20.1.56 | Columnfa5e1et100UtpLinkLocal | read-only | current | 5E1-ET100T Series card UTP link status: 0:Link Down 1:Link Up |
| 1.3.6.1.4.1.4756.20.110.20.1.57 | Columnfa5e1et100UtpStatusLocal | read-only | current | 5E1-ET100T Series card UTP link mode status: 0:None, Maybe link down 1:Link at 10Mbps, Half duplex 2:Link at 10Mbps, Full duplex 3:Link at 100Mbps, Half duplex… |
| 1.3.6.1.4.1.4756.20.110.20.1.58 | Columnfa5e1et100UtpFlowCtrlStsLocal | read-only | current | 5E1-ET100T Series card UTP flow control status: 0:Disable 1:Enable |
| 1.3.6.1.4.1.4756.20.110.20.1.59 | Columnfa5e1et100UtpModeLocal | read-write | current | 5E1-ET100T Series card UTP mode: 0:Disable 1:Enable and autoNegotiation 3:Enable and force to 10Mbps, Half duplex 4:Enable and force to 10Mbps, Full duplex 5:E… |
| 1.3.6.1.4.1.4756.20.110.20.1.60 | Columnfa5e1et100UtpFlowCtrlLocal | read-write | current | 5E1-ET100T Series card UTP flow control: 0:Disable 1:Enable |
| 1.3.6.1.4.1.4756.20.110.20.1.61 | Columnfa5e1et100SpeedLimitLocal | read-write | current | 5E1-ET100(T/S) Series card speed limit: Limited = this value * 32Kbps, this value is restricted to 0 ~ 3125, 0 to disable |
| 1.3.6.1.4.1.4756.20.110.20.1.62 | Columnfa5e1et100VlanAwareLocal | read-write | current | 5E1-ET100(T/S) Series card 802.1q VLAN tag aware: 0:Disable 1:Enable |
| 1.3.6.1.4.1.4756.20.110.20.1.63 | Columnfa5e1et100VlanIDLocal | read-write | current | 5E1-ET100(T/S) Series card VLAN ID: The ID is restricted to 1 ~ 4094 |
| 1.3.6.1.4.1.4756.20.110.20.1.64 | Columnfa5e1et100RemoteDeviceLocal | read-only | current | FRM220A-5E1 Series card remote device status: 0:Link Down 1:Link Up |
| 1.3.6.1.4.1.4756.20.110.20.1.65 | Columnfa5e1et100RemotePowerLocal | read-only | current | 5E1-ET100(T/S) Series card remote device power status: 0:Normal 1:Power off |
| 1.3.6.1.4.1.4756.20.110.20.1.66 | Columnfa5e1et100TimingSourceLocal | read-write | current | 5E1-ET100(T/S) Series card clock: 0:Internal oscillatro 1:Recovery from E1 channel 1 2:Recovery from E1 channel 2 3:Recovery from E1 channel 3 4:Recovery from … |
| 1.3.6.1.4.1.4756.20.110.20.1.67 | Columnfa5e1et100FCSofGFPLocal | read-write | current | 5E1-ET100(T/S) Series card FCS of GFP: 0:Disable 1:Enable |
| 1.3.6.1.4.1.4756.20.110.20.1.68 | Columnfa5e1et100AutoChAdjustLocal | read-write | current | 5E1-ET100(T/S) Series card auto channel Bdjust: 0:Disable 1:Enable |
| 1.3.6.1.4.1.4756.20.110.20.1.69 | Columnfa5e1et100PayloadScrambleLocal | read-write | current | 5E1-ET100(T/S) Series card payload scramble: 0:Disable 1:Enable |
| 1.3.6.1.4.1.4756.20.110.20.1.70 | Columnfa5e1et100FailoverLocal | read-write | current | 5E1-ET100(T/S) Series card failover: 0:Disable 1:Enable |
| 1.3.6.1.4.1.4756.20.110.20.1.71 | Columnfa5e1et100LOMLocal | read-only | current | 5E1-ET100(T/S) Series card LOM status: 0:No 1:Yes |
| 1.3.6.1.4.1.4756.20.110.20.1.72 | Columnfa5e1et100SQMLocal | read-only | current | 5E1-ET100(T/S) Series card SQM status: 0:No 1:Yes |
| 1.3.6.1.4.1.4756.20.110.20.1.73 | Columnfa5e1et100CRCLocal | read-only | current | 5E1-ET100(T/S) Series card CRC status: 0:No 1:Yes |
| 1.3.6.1.4.1.4756.20.110.20.1.74 | Columnfa5e1et100LOALocal | read-only | current | 5E1-ET100(T/S) Series card LOA status: 0:No 1:Yes |
| 1.3.6.1.4.1.4756.20.110.20.1.75 | Columnfa5e1et100LFDLocal | read-only | current | 5E1-ET100(T/S) Series card LFD status: 0:No 1:Yes |
| 1.3.6.1.4.1.4756.20.110.20.1.76 | Columnfa5e1et100DDTOLocal | read-only | current | 5E1-ET100(T/S) Series card DDTO status: 0:No 1:Yes |
| 1.3.6.1.4.1.4756.20.110.20.1.77 | Columnfa5e1et100VcatMember1Local | read-write | current | 5E1-ET100(T/S) Series card VACT member 0: 0:Disable 1:Enable |
| 1.3.6.1.4.1.4756.20.110.20.1.78 | Columnfa5e1et100VcatMember2Local | read-write | current | 5E1-ET100(T/S) Series card VACT member 1: 0:Disable 1:Enable |
| 1.3.6.1.4.1.4756.20.110.20.1.79 | Columnfa5e1et100VcatMember3Local | read-write | current | 5E1-ET100(T/S) Series card VACT member 3: 0:Disable 1:Enable |
| 1.3.6.1.4.1.4756.20.110.20.1.80 | Columnfa5e1et100VcatMember4Local | read-write | current | 5E1-ET100(T/S) Series card VACT member 4: 0:Disable 1:Enable |
| 1.3.6.1.4.1.4756.20.110.20.1.81 | Columnfa5e1et100VcatMember5Local | read-write | current | 5E1-ET100(T/S) Series card VACT member 5: 0:Disable 1:Enable |
| 1.3.6.1.4.1.4756.20.110.20.1.82 | Columnfa5e1et100SnmpChannel1Local | read-write | current | 5E1-ET100(T/S) Series card SNMP channel 0: 0:No use 1:Use |
| 1.3.6.1.4.1.4756.20.110.20.1.83 | Columnfa5e1et100SnmpChannel2Local | read-write | current | 5E1-ET100(T/S) Series card SNMP channel 1: 0:No use 1:Use |
| 1.3.6.1.4.1.4756.20.110.20.1.84 | Columnfa5e1et100SnmpChannel3Local | read-write | current | 5E1-ET100(T/S) Series card SNMP channel 3: 0:No use 1:Use |
| 1.3.6.1.4.1.4756.20.110.20.1.85 | Columnfa5e1et100SnmpChannel4Local | read-write | current | 5E1-ET100(T/S) Series card SNMP channel 4: 0:No use 1:Use |
| 1.3.6.1.4.1.4756.20.110.20.1.86 | Columnfa5e1et100ErrSecLocal | read-only | current | 5E1-ET100(T/S) Series card, errored seconds of BERT result. |
| 1.3.6.1.4.1.4756.20.110.20.1.87 | Columnfa5e1et100ErrFreeSecLocal | read-only | current | 5E1-ET100(T/S) Series card, errored free seconds of BERT result. |
| 1.3.6.1.4.1.4756.20.110.20.1.88 | Columnfa5e1et100ServErrSecLocal | read-only | current | 5E1-ET100(T/S) Series card, severely errored seconds of BERT result. |
| 1.3.6.1.4.1.4756.20.110.20.1.89 | Columnfa5e1et100BertFunctionLocal | read-write | current | 5E1-ET100(T/S) Series card bert function: 0:Disable 1:Enable |
| 1.3.6.1.4.1.4756.20.110.20.1.90 | Columnfa5e1et100ClrBertDataLocal | read-write | current | 5E1-ET100(T/S) Series card bert data clear: 0:Normal 1:Clear |
| 1.3.6.1.4.1.4756.20.110.20.1.91 | Columnfa5e1et100BertE1ChannelLocal | read-write | current | 5E1-ET100(T/S) Series card bert E1 channel number: 0:E1 channel 1 1:E1 channel 2 2:E1 channel 3 3:E1 channel 4 4:E1 channel 5 |
| 1.3.6.1.4.1.4756.20.110.20.1.92 | Columnfa5e1et100RmonFunctionLocal | read-write | current | 5E1-ET100(T/S) Series RMON function : 0:Disable 1:Enable |
| 1.3.6.1.4.1.4756.20.110.20.1.93 | Columnfa5e1et100RmonTxLocal | read-only | current | 5E1-ET100(T/S) Series card RMON Tx counter. |
| 1.3.6.1.4.1.4756.20.110.20.1.94 | Columnfa5e1et100RmonRxLocal | read-only | current | 5E1-ET100(T/S) Series card RMON Rx counter. |
| 1.3.6.1.4.1.4756.20.110.20.1.95 | Columnfa5e1et100ClrRmonTxLocal | read-write | current | 5E1-ET100(T/S) Series card clear RMON Tx counter: 0:Normal 1:Clear |
| 1.3.6.1.4.1.4756.20.110.20.1.96 | Columnfa5e1et100ClrRmonRxLocal | read-write | current | 5E1-ET100(T/S) Series card clear RMON Rx counter: 0:Normal 1:Clear |
| 1.3.6.1.4.1.4756.20.110.20.1.97 | Columnfa5e1et100SfpLocal | read-only | current | 5E1-ET100(T/S) Series card, SFP existed: 0:No 1:Yes |
| 1.3.6.1.4.1.4756.20.110.20.1.98 | Columnfa5e1et100SfpVendorLocal | read-only | current | 5E1-ET100(T/S) Series card, Vendor name of SFP. |
| 1.3.6.1.4.1.4756.20.110.20.1.99 | Columnfa5e1et100SfpPartNoLocal | read-only | current | 5E1-ET100(T/S) Series card, Vendor part number of SFP. |
| 1.3.6.1.4.1.4756.20.110.20.1.100 | Columnfa5e1et100SfpFiberTypeLocal | read-only | current | 5E1-ET100(T/S) Series card, Fiber Type of SFP. |
| 1.3.6.1.4.1.4756.20.110.20.1.101 | Columnfa5e1et100SfpTxWaveLenLocal | read-only | current | 5E1-ET100(T/S) Series card, Tx Wave length of SFP. |
| 1.3.6.1.4.1.4756.20.110.20.1.102 | Columnfa5e1et100SfpRxWaveLenLocal | read-only | current | 5E1-ET100(T/S) Series card, Rx Wave length of SFP. |
| 1.3.6.1.4.1.4756.20.110.20.1.103 | Columnfa5e1et100SfpLinkLenLocal | read-only | current | 5E1-ET100(T/S) Series card, Link length of SFP. |
| 1.3.6.1.4.1.4756.20.110.20.1.104 | Columnfa5e1et100SfpModelIDLocal | read-only | current | 5E1-ET100(T/S) Series card, model ID of SFP. |
| 1.3.6.1.4.1.4756.20.110.20.1.105 | Columnfa5e1et100SfpVersionLocal | read-only | current | 5E1-ET100(T/S) Series card, the version of SFP. |
| 1.3.6.1.4.1.4756.20.110.20.1.106 | Columnfa5e1et100SfpModelTypeLocal | read-only | current | 5E1-ET100(T/S) Series card, model type of SFP. |
| 1.3.6.1.4.1.4756.20.110.20.1.107 | Columnfa5e1et100DDInformationLocal | read-only | current | 5E1-ET100(T/S) Series card, D/D information of SFP Supported: 0:No, 1:Yes |
| 1.3.6.1.4.1.4756.20.110.20.1.108 | Columnfa5e1et100DDRxSensLocal | read-only | current | 5E1-ET100(T/S) Series card, Sensitivity of D/D information. |
| 1.3.6.1.4.1.4756.20.110.20.1.109 | Columnfa5e1et100DDTxPowerLocal | read-only | current | 5E1-ET100(T/S) Series card, Tx power of D/D information. |
| 1.3.6.1.4.1.4756.20.110.20.1.110 | Columnfa5e1et100DDRxPowerLocal | read-only | current | 5E1-ET100(T/S) Series card, Rx power of D/D information. |
| 1.3.6.1.4.1.4756.20.110.20.1.111 | Columnfa5e1et100DDTempLocal | read-only | current | 5E1-ET100(T/S) Series card, Temperature of D/D information in degree C. |
| 1.3.6.1.4.1.4756.20.110.20.1.112 | Columnfa5e1et100DDBiasLocal | read-only | current | 5E1-ET100(T/S) Series card, BIAS of D/D information. |
| 1.3.6.1.4.1.4756.20.110.20.1.113 | Columnfa5e1et100DDVoltageLocal | read-only | current | 5E1-ET100(T/S) Series card, Voltage of D/D information. |
| 1.3.6.1.4.1.4756.20.110.20.1.114 | Columnfa5e1et100ChannelDefectLocal | read-write | current | 5E1-ET100(T/S) Series card Channel Defect: 0:Disable 4:1E-4 6:1E-6 |
| 1.3.6.1.4.1.4756.20.110.20.1.115 | Columnfa5e1et100LoopDetectionLocal | read-write | current | 5E1-ET100(T/S) Series card Loop Detection: 0:Disable 1:Enable |
| 1.3.6.1.4.1.4756.20.110.20.1.116 | Columnfa5e1et100LoopCh1Local | read-only | current | 5E1-ET100(T/S) Series card E1 channel 1 Loop Check State: 0:No 1:Yes |
| 1.3.6.1.4.1.4756.20.110.20.1.117 | Columnfa5e1et100LoopCh2Local | read-only | current | 5E1-ET100(T/S) Series card E1 channel 2 Loop Check State: 0:No 1:Yes |
| 1.3.6.1.4.1.4756.20.110.20.1.118 | Columnfa5e1et100LoopCh3Local | read-only | current | 5E1-ET100(T/S) Series card E1 channel 3 Loop Check State: 0:No 1:Yes |
| 1.3.6.1.4.1.4756.20.110.20.1.119 | Columnfa5e1et100LoopCh4Local | read-only | current | 5E1-ET100(T/S) Series card E1 channel 4 Loop Check State: 0:No 1:Yes |
| 1.3.6.1.4.1.4756.20.110.20.1.120 | Columnfa5e1et100LoopCh5Local | read-only | current | 5E1-ET100(T/S) Series card E1 channel 5 Loop Check State: 0:No 1:Yes |
| 1.3.6.1.4.1.4756.20.110.20.1.121 | Columnfa5e1et100DefectCh1Local | read-only | current | 5E1-ET100(T/S) Series card E1 channel 1 Defect Status: 0:No 1:Yes |
| 1.3.6.1.4.1.4756.20.110.20.1.122 | Columnfa5e1et100DefectCh2Local | read-only | current | 5E1-ET100(T/S) Series card E1 channel 2 Defect Status: 0:No 1:Yes |
| 1.3.6.1.4.1.4756.20.110.20.1.123 | Columnfa5e1et100DefectCh3Local | read-only | current | 5E1-ET100(T/S) Series card E1 channel 3 Defect Status: 0:No 1:Yes |
| 1.3.6.1.4.1.4756.20.110.20.1.124 | Columnfa5e1et100DefectCh4Local | read-only | current | 5E1-ET100(T/S) Series card E1 channel 4 Defect Status: 0:No 1:Yes |
| 1.3.6.1.4.1.4756.20.110.20.1.125 | Columnfa5e1et100DefectCh5Local | read-only | current | 5E1-ET100(T/S) Series card E1 channel 5 Defect Status: 0:No 1:Yes |
| 1.3.6.1.4.1.4756.20.110.20.1.126 | Columnfa5e1et100FxSignalLocal | read-only | current | 5E1-ET100(T/S) Series card Fiber signal detect(SD): 0:Fiber unplugged 1:Signal detected |
| 1.3.6.1.4.1.4756.20.110.20.1.127 | Columnfa5e1et100PortResetLocal | read-write | current | 5E1-ET100(T/S) Series card Port Reset: 0:Off 1:Action |
| 1.3.6.1.4.1.4756.20.110.20.1.128 | Columnfa5e1et100VLANModeLocal | read-write | current | 5E1-ET100(T/S) Series card VLAN mode: 0:MODE2 1:MODE1 |
| 1.3.6.1.4.1.4756.20.110.20.1.129 | Columnfa5e1et100ETagSelectEntryLocal | read-write | current | 5E1-ET100(T/S) Series card ETag select entry: |
| 1.3.6.1.4.1.4756.20.110.20.1.130 | Columnfa5e1et100ETagMethodLocal | read-write | current | 5E1-ET100(T/S) Series card ETag Method: 0: Intouch 1: Add Tag 2: Remove Tag |
| 1.3.6.1.4.1.4756.20.110.20.1.131 | Columnfa5e1et100VLANTableVID1Local | read-write | current | 5E1-ET100(T/S) Series card VLAN Table: VLAN ID1 |
| 1.3.6.1.4.1.4756.20.110.20.1.132 | Columnfa5e1et100VLANTableVID2Local | read-write | current | 5E1-ET100(T/S) Series card VLAN Table: VLAN ID2 |
| 1.3.6.1.4.1.4756.20.110.20.1.133 | Columnfa5e1et100VLANTableVID3Local | read-write | current | 5E1-ET100(T/S) Series card VLAN Table: VLAN ID3 |
| 1.3.6.1.4.1.4756.20.110.20.1.134 | Columnfa5e1et100VLANTableVID4Local | read-write | current | 5E1-ET100(T/S) Series card VLAN Table: VLAN ID4 |
| 1.3.6.1.4.1.4756.20.110.20.1.135 | Columnfa5e1et100VLANTableVID5Local | read-write | current | 5E1-ET100(T/S) Series card VLAN Table: VLAN ID5 |
| 1.3.6.1.4.1.4756.20.110.20.1.136 | Columnfa5e1et100VLANTableVID6Local | read-write | current | 5E1-ET100(T/S) Series card VLAN Table: VLAN ID6 |
| 1.3.6.1.4.1.4756.20.110.20.1.137 | Columnfa5e1et100VLANTableVID7Local | read-write | current | 5E1-ET100(T/S) Series card VLAN Table: VLAN ID7 |
| 1.3.6.1.4.1.4756.20.110.20.1.138 | Columnfa5e1et100VLANTableVID8Local | read-write | current | 5E1-ET100(T/S) Series card VLAN Table: VLAN ID8 |
| 1.3.6.1.4.1.4756.20.110.20.1.139 | Columnfa5e1et100VLANTableVID9Local | read-write | current | 5E1-ET100(T/S) Series card VLAN Table: VLAN ID9 |
| 1.3.6.1.4.1.4756.20.110.20.1.140 | Columnfa5e1et100VLANTableVID10Local | read-write | current | 5E1-ET100(T/S) Series card VLAN Table: VLAN ID10 |
| 1.3.6.1.4.1.4756.20.110.20.1.141 | Columnfa5e1et100VLANTableVID11Local | read-write | current | 5E1-ET100(T/S) Series card VLAN Table: VLAN ID11 |
| 1.3.6.1.4.1.4756.20.110.20.1.142 | Columnfa5e1et100VLANTableVID12Local | read-write | current | 5E1-ET100(T/S) Series card VLAN Table: VLAN ID12 |
| 1.3.6.1.4.1.4756.20.110.20.1.143 | Columnfa5e1et100VLANTableVID13Local | read-write | current | 5E1-ET100(T/S) Series card VLAN Table: VLAN ID13 |
| 1.3.6.1.4.1.4756.20.110.20.1.144 | Columnfa5e1et100VLANTableVID14Local | read-write | current | 5E1-ET100(T/S) Series card VLAN Table: VLAN ID14 |
| 1.3.6.1.4.1.4756.20.110.20.1.145 | Columnfa5e1et100VLANTableVID15Local | read-write | current | 5E1-ET100(T/S) Series card VLAN Table: VLAN ID15 |
| 1.3.6.1.4.1.4756.20.110.20.1.146 | Columnfa5e1et100VLANTableVID16Local | read-write | current | 5E1-ET100(T/S) Series card VLAN Table: VLAN ID16 |
| 1.3.6.1.4.1.4756.20.111 | Nodef5E1RemoteCards | |||
| 1.3.6.1.4.1.4756.20.111.20 | Tablef5E1RemoteTable | not-accessible | current | A list of local FRM220-5E1-ET100 series card entries. The number of entries is f5E1-No-R. |
| 1.3.6.1.4.1.4756.20.111.20.1 | Rowf5E1RemoteEntry | not-accessible | current | An entry containing management information applicable to a particular local FRM220-5E1 series card. |
| 1.3.6.1.4.1.4756.20.111.20.1.1 | Columnfa5e1et100ChassisIndexRemote | read-only | current | A unique value for each card. It starts from 0 to 9 contiguously. |
| 1.3.6.1.4.1.4756.20.111.20.1.2 | Columnfa5e1et100SlotIndexRemote | read-only | current | A unique value for each card. It starts from 1 to 20 contiguously. |
| 1.3.6.1.4.1.4756.20.111.20.1.3 | Columnfa5e1et100CardHWVerRemote | read-only | current | 5E1-ET100(T/S) Series card hardware version x.xxx |
| 1.3.6.1.4.1.4756.20.111.20.1.4 | Columnfa5e1et100CardFWVerRemote | read-only | current | 5E1-ET100(T/S) Series card firmware version x.xxx |
| 1.3.6.1.4.1.4756.20.111.20.1.5 | Columnfa5e1et100CardCPLDVerRemote | read-only | current | 5E1-ET100(T/S) Series card CPLD version x.xxx |
| 1.3.6.1.4.1.4756.20.111.20.1.6 | Columnfa5e1et100CardFPGAVerRemote | read-only | current | 5E1-ET100(T/S) Series card FPGA version x.xxx |
| 1.3.6.1.4.1.4756.20.111.20.1.7 | Columnfa5e1et100ModelRemote | read-only | current | Card Type: 0:5E1-ET100T 1:5E1-ET100S |
| 1.3.6.1.4.1.4756.20.111.20.1.8 | Columnfa5e1et100SystemStatusRemote | read-only | current | 5E1-ET100(T/S) Series card system status: 0:Normal 1:Alarm |
| 1.3.6.1.4.1.4756.20.111.20.1.9 | Columnfa5e1et100DeviceActiveRemote | read-only | current | 5E1-ET100(T/S) Series card active: 0:Disable 1:Enable |
| 1.3.6.1.4.1.4756.20.111.20.1.10 | Columnfa5e1et100SetToDefaultRemote | read-write | current | 5E1-ET100(T/S) Series card port set to default: 0:Off 1:Trigger |
| 1.3.6.1.4.1.4756.20.111.20.1.11 | Columnfa5e1et100E1Ch1SingalRemote | read-only | current | 5E1-ET100(T/S) Series card E1 channel 1 signal status: 0:Singal Loss 1:Normal |
| 1.3.6.1.4.1.4756.20.111.20.1.12 | Columnfa5e1et100E1Ch2SingalRemote | read-only | current | 5E1-ET100(T/S) Series card E1 channel 2 signal status: 0:Singal Loss 1:Normal |
| 1.3.6.1.4.1.4756.20.111.20.1.13 | Columnfa5e1et100E1Ch3SingalRemote | read-only | current | 5E1-ET100(T/S) Series card E1 channel 3 signal status: 0:Singal Loss 1:Normal |
| 1.3.6.1.4.1.4756.20.111.20.1.14 | Columnfa5e1et100E1Ch4SingalRemote | read-only | current | 5E1-ET100(T/S) Series card E1 channel 4 signal status: 0:Singal Loss 1:Normal |
| 1.3.6.1.4.1.4756.20.111.20.1.15 | Columnfa5e1et100E1Ch5SingalRemote | read-only | current | 5E1-ET100(T/S) Series card E1 channel 5 signal status: 0:Singal Loss 1:Normal |
| 1.3.6.1.4.1.4756.20.111.20.1.16 | Columnfa5e1et100E1Ch1SyncRemote | read-only | current | 5E1-ET100(T/S) Series card E1 channel 1 sync status: 0:Sync Loss 1:Sync |
| 1.3.6.1.4.1.4756.20.111.20.1.17 | Columnfa5e1et100E1Ch2SyncRemote | read-only | current | 5E1-ET100(T/S) Series card E1 channel 2 sync status: 0:Sync Loss 1:Sync |
| 1.3.6.1.4.1.4756.20.111.20.1.18 | Columnfa5e1et100E1Ch3SyncRemote | read-only | current | 5E1-ET100(T/S) Series card E1 channel 3 sync status: 0:Sync Loss 1:Sync |
| 1.3.6.1.4.1.4756.20.111.20.1.19 | Columnfa5e1et100E1Ch4SyncRemote | read-only | current | 5E1-ET100(T/S) Series card E1 channel 4 sync status: 0:Sync Loss 1:Sync |
| 1.3.6.1.4.1.4756.20.111.20.1.20 | Columnfa5e1et100E1Ch5SyncRemote | read-only | current | 5E1-ET100(T/S) Series card E1 channel 5 sync status: 0:Sync Loss 1:Sync |
| 1.3.6.1.4.1.4756.20.111.20.1.21 | Columnfa5e1et100E1Ch1RecvAISRemote | read-only | current | 5E1-ET100(T/S) Series card E1 channel 1 receive AIS status: 0:No 1:Yes |
| 1.3.6.1.4.1.4756.20.111.20.1.22 | Columnfa5e1et100E1Ch2RecvAISRemote | read-only | current | 5E1-ET100(T/S) Series card E1 channel 2 receive AIS status: 0:No 1:Yes |
| 1.3.6.1.4.1.4756.20.111.20.1.23 | Columnfa5e1et100E1Ch3RecvAISRemote | read-only | current | 5E1-ET100(T/S) Series card E1 channel 3 receive AIS status: 0:No 1:Yes |
| 1.3.6.1.4.1.4756.20.111.20.1.24 | Columnfa5e1et100E1Ch4RecvAISRemote | read-only | current | 5E1-ET100(T/S) Series card E1 channel 4 receive AIS status: 0:No 1:Yes |
| 1.3.6.1.4.1.4756.20.111.20.1.25 | Columnfa5e1et100E1Ch5RecvAISRemote | read-only | current | 5E1-ET100(T/S) Series card E1 channel 5 receive AIS status: 0:No 1:Yes |
| 1.3.6.1.4.1.4756.20.111.20.1.26 | Columnfa5e1et100E1Ch1ConnTypeRemote | read-only | current | 5E1-ET100(T/S) Series card E1 channel 1 connector type: 0:RJ-48C 1:BNC |
| 1.3.6.1.4.1.4756.20.111.20.1.27 | Columnfa5e1et100E1Ch2ConnTypeRemote | read-only | current | 5E1-ET100(T/S) Series card E1 channel 2 connector type: 0:RJ-48C 1:BNC |
| 1.3.6.1.4.1.4756.20.111.20.1.28 | Columnfa5e1et100E1Ch3ConnTypeRemote | read-only | current | 5E1-ET100(T/S) Series card E1 channel 3 connector type: 0:RJ-48C 1:BNC |
| 1.3.6.1.4.1.4756.20.111.20.1.29 | Columnfa5e1et100E1Ch4ConnTypeRemote | read-only | current | 5E1-ET100(T/S) Series card E1 channel 4 connector type: 0:RJ-48C 1:BNC |
| 1.3.6.1.4.1.4756.20.111.20.1.30 | Columnfa5e1et100E1Ch5ConnTypeRemote | read-only | current | 5E1-ET100(T/S) Series card E1 channel 5 connector type: 0:RJ-48C 1:BNC |
| 1.3.6.1.4.1.4756.20.111.20.1.31 | Columnfa5e1et100E1Ch1RAIRemote | read-only | current | 5E1-ET100(T/S) Series card E1 channel 1 RAI status: 0:No 1:Yes |
| 1.3.6.1.4.1.4756.20.111.20.1.32 | Columnfa5e1et100E1Ch2RAIRemote | read-only | current | 5E1-ET100(T/S) Series card E1 channel 2 RAI status: 0:No 1:Yes |
| 1.3.6.1.4.1.4756.20.111.20.1.33 | Columnfa5e1et100E1Ch3RAIRemote | read-only | current | 5E1-ET100(T/S) Series card E1 channel 3 RAI status: 0:No 1:Yes |
| 1.3.6.1.4.1.4756.20.111.20.1.34 | Columnfa5e1et100E1Ch4RAIRemote | read-only | current | 5E1-ET100(T/S) Series card E1 channel 4 RAI status: 0:No 1:Yes |
| 1.3.6.1.4.1.4756.20.111.20.1.35 | Columnfa5e1et100E1Ch5RAIRemote | read-only | current | 5E1-ET100(T/S) Series card E1 channel 5 RAI status: 0:No 1:Yes |
| 1.3.6.1.4.1.4756.20.111.20.1.36 | Columnfa5e1et100E1Ch1LOMFRemote | read-only | current | 5E1-ET100(T/S) Series card E1 channel 1 LOMF status: 0:No 1:Yes |
| 1.3.6.1.4.1.4756.20.111.20.1.37 | Columnfa5e1et100E1Ch2LOMFRemote | read-only | current | 5E1-ET100(T/S) Series card E1 channel 2 LOMF status: 0:No 1:Yes |
| 1.3.6.1.4.1.4756.20.111.20.1.38 | Columnfa5e1et100E1Ch3LOMFRemote | read-only | current | 5E1-ET100(T/S) Series card E1 channel 3 LOMF status: 0:No 1:Yes |
| 1.3.6.1.4.1.4756.20.111.20.1.39 | Columnfa5e1et100E1Ch4LOMFRemote | read-only | current | 5E1-ET100(T/S) Series card E1 channel 4 LOMF status: 0:No 1:Yes |
| 1.3.6.1.4.1.4756.20.111.20.1.40 | Columnfa5e1et100E1Ch5LOMFRemote | read-only | current | 5E1-ET100(T/S) Series card E1 channel 5 LOMF status: 0:No 1:Yes |
| 1.3.6.1.4.1.4756.20.111.20.1.41 | Columnfa5e1et100E1Ch1ActiveRemote | read-only | current | 5E1-ET100(T/S) Series card E1 channel 1 active status: 0:Inactive 1:Active |
| 1.3.6.1.4.1.4756.20.111.20.1.42 | Columnfa5e1et100E1Ch2ActiveRemote | read-only | current | 5E1-ET100(T/S) Series card E1 channel 2 active status: 0:Inactive 1:Active |
| 1.3.6.1.4.1.4756.20.111.20.1.43 | Columnfa5e1et100E1Ch3ActiveRemote | read-only | current | 5E1-ET100(T/S) Series card E1 channel 3 active status: 0:Inactive 1:Active |
| 1.3.6.1.4.1.4756.20.111.20.1.44 | Columnfa5e1et100E1Ch4ActiveRemote | read-only | current | 5E1-ET100(T/S) Series card E1 channel 4 active status: 0:Inactive 1:Active |
| 1.3.6.1.4.1.4756.20.111.20.1.45 | Columnfa5e1et100E1Ch5ActiveRemote | read-only | current | 5E1-ET100(T/S) Series card E1 channel 5 active status: 0:Inactive 1:Active |
| 1.3.6.1.4.1.4756.20.111.20.1.46 | Columnfa5e1et100E1Ch1LoopBackRemote | read-write | current | 5E1-ET100(T/S) Series card port E1 channel 1 loop back: 0:Off 2:RLB (Max used 4 channels) |
| 1.3.6.1.4.1.4756.20.111.20.1.47 | Columnfa5e1et100E1Ch2LoopBackRemote | read-write | current | 5E1-ET100(T/S) Series card port E1 channel 2 loop back: 0:Off 2:RLB (Max used 4 channels) |
| 1.3.6.1.4.1.4756.20.111.20.1.48 | Columnfa5e1et100E1Ch3LoopBackRemote | read-write | current | 5E1-ET100(T/S) Series card port E1 channel 3 loop back: 0:Off 2:RLB (Max used 4 channels) |
| 1.3.6.1.4.1.4756.20.111.20.1.49 | Columnfa5e1et100E1Ch4LoopBackRemote | read-write | current | 5E1-ET100(T/S) Series card port E1 channel 4 loop back: 0:Off 2:RLB (Max used 4 channels) |
| 1.3.6.1.4.1.4756.20.111.20.1.50 | Columnfa5e1et100E1Ch5LoopBackRemote | read-write | current | 5E1-ET100(T/S) Series card port E1 channel 5 loop back: 0:Off 2:RLB (Max used 4 channels) |
| 1.3.6.1.4.1.4756.20.111.20.1.51 | Columnfa5e1et100FxLinkRemote | read-only | current | 5E1-ET100S Series card Fiber siganl detect status: 0:Down or Fiber unplugged 1:Up or Singal detected |
| 1.3.6.1.4.1.4756.20.111.20.1.52 | Columnfa5e1et100FxLaserRemote | read-only | current | 5E1-ET100S Series card laser status: 0:Normal 1:Error |
| 1.3.6.1.4.1.4756.20.111.20.1.53 | Columnfa5e1et100FxActiveRemote | read-write | current | 5E1-ET100S Series card Fiber active: 0:Inactive 1:Active |
| 1.3.6.1.4.1.4756.20.111.20.1.54 | Columnfa5e1et100FxLaserOutputRemote | read-write | current | 5E1-ET100S Series card laser output: 0:disable 1:Enable |
| 1.3.6.1.4.1.4756.20.111.20.1.55 | Columnfa5e1et100FxOpModeRemote | read-write | current | 5E1-ET100S Series card operation mode: 0:Switch 1:Convert |
| 1.3.6.1.4.1.4756.20.111.20.1.56 | Columnfa5e1et100UtpLinkRemote | read-only | current | 5E1-ET100T Series card UTP link status: 0:Link Down 1:Link Up |
| 1.3.6.1.4.1.4756.20.111.20.1.57 | Columnfa5e1et100UtpStatusRemote | read-only | current | 5E1-ET100T Series card UTP link mode status: 0:None, Maybe link down 1:Link at 10Mbps, Half duplex 2:Link at 10Mbps, Full duplex 3:Link at 100Mbps, Half duplex… |
| 1.3.6.1.4.1.4756.20.111.20.1.58 | Columnfa5e1et100UtpFlowCtrlStsRemote | read-only | current | 5E1-ET100T Series card UTP flow control status: 0:Disable 1:Enable |
| 1.3.6.1.4.1.4756.20.111.20.1.59 | Columnfa5e1et100UtpModeRemote | read-write | current | 5E1-ET100T Series card UTP mode: 0:Disable 1:Enable and autoNegotiation 3:Enable and force to 10Mbps, Half duplex 4:Enable and force to 10Mbps, Full duplex 5:E… |
| 1.3.6.1.4.1.4756.20.111.20.1.60 | Columnfa5e1et100UtpFlowCtrlRemote | read-write | current | 5E1-ET100T Series card UTP flow control: 0:Disable 1:Enable |
| 1.3.6.1.4.1.4756.20.111.20.1.61 | Columnfa5e1et100SpeedLimitRemote | read-write | current | 5E1-ET100(T/S) Series card speed limit: Limited = this value * 32Kbps, this value is restricted to 0 ~ 3125, 0 to disable |
| 1.3.6.1.4.1.4756.20.111.20.1.62 | Columnfa5e1et100VlanAwareRemote | read-write | current | 5E1-ET100(T/S) Series card 802.1q VLAN tag aware: 0:Disable 1:Enable |
| 1.3.6.1.4.1.4756.20.111.20.1.63 | Columnfa5e1et100VlanIDRemote | read-write | current | 5E1-ET100(T/S) Series card VLAN ID: The ID is restricted to 1 ~ 4094 |
| 1.3.6.1.4.1.4756.20.111.20.1.64 | Columnfa5e1et100RemoteDeviceRemote | read-only | current | FRM220A-5E1 Series card remote device status: 0:Link Down 1:Link Up |
| 1.3.6.1.4.1.4756.20.111.20.1.65 | Columnfa5e1et100RemotePowerRemote | read-only | current | 5E1-ET100(T/S) Series card remote device power status: 0:Normal 1:Power off |
| 1.3.6.1.4.1.4756.20.111.20.1.66 | Columnfa5e1et100TimingSourceRemote | read-write | current | 5E1-ET100(T/S) Series card clock: 0:Internal oscillatro 1:Recovery from E1 channel 1 2:Recovery from E1 channel 2 3:Recovery from E1 channel 3 4:Recovery from … |
| 1.3.6.1.4.1.4756.20.111.20.1.67 | Columnfa5e1et100FCSofGFPRemote | read-write | current | 5E1-ET100(T/S) Series card FCS of GFP: 0:Disable 1:Enable |
| 1.3.6.1.4.1.4756.20.111.20.1.68 | Columnfa5e1et100AutoChAdjustRemote | read-write | current | 5E1-ET100(T/S) Series card auto channel Bdjust: 0:Disable 1:Enable |
| 1.3.6.1.4.1.4756.20.111.20.1.69 | Columnfa5e1et100PayloadScrambleRemote | read-write | current | 5E1-ET100(T/S) Series card payload scramble: 0:Disable 1:Enable |
| 1.3.6.1.4.1.4756.20.111.20.1.70 | Columnfa5e1et100FailoverRemote | read-write | current | 5E1-ET100(T/S) Series card failover: 0:Disable 1:Enable |
| 1.3.6.1.4.1.4756.20.111.20.1.71 | Columnfa5e1et100LOMRemote | read-only | current | 5E1-ET100(T/S) Series card LOM status: 0:No 1:Yes |
| 1.3.6.1.4.1.4756.20.111.20.1.72 | Columnfa5e1et100SQMRemote | read-only | current | 5E1-ET100(T/S) Series card SQM status: 0:No 1:Yes |
| 1.3.6.1.4.1.4756.20.111.20.1.73 | Columnfa5e1et100CRCRemote | read-only | current | 5E1-ET100(T/S) Series card CRC status: 0:No 1:Yes |
| 1.3.6.1.4.1.4756.20.111.20.1.74 | Columnfa5e1et100LOARemote | read-only | current | 5E1-ET100(T/S) Series card LOA status: 0:No 1:Yes |
| 1.3.6.1.4.1.4756.20.111.20.1.75 | Columnfa5e1et100LFDRemote | read-only | current | 5E1-ET100(T/S) Series card LFD status: 0:No 1:Yes |
| 1.3.6.1.4.1.4756.20.111.20.1.76 | Columnfa5e1et100DDTORemote | read-only | current | 5E1-ET100(T/S) Series card DDTO status: 0:No 1:Yes |
| 1.3.6.1.4.1.4756.20.111.20.1.77 | Columnfa5e1et100VcatMember1Remote | read-write | current | 5E1-ET100(T/S) Series card VACT member 0: 0:Disable 1:Enable |
| 1.3.6.1.4.1.4756.20.111.20.1.78 | Columnfa5e1et100VcatMember2Remote | read-write | current | 5E1-ET100(T/S) Series card VACT member 1: 0:Disable 1:Enable |
| 1.3.6.1.4.1.4756.20.111.20.1.79 | Columnfa5e1et100VcatMember3Remote | read-write | current | 5E1-ET100(T/S) Series card VACT member 3: 0:Disable 1:Enable |
| 1.3.6.1.4.1.4756.20.111.20.1.80 | Columnfa5e1et100VcatMember4Remote | read-write | current | 5E1-ET100(T/S) Series card VACT member 4: 0:Disable 1:Enable |
| 1.3.6.1.4.1.4756.20.111.20.1.81 | Columnfa5e1et100VcatMember5Remote | read-write | current | 5E1-ET100(T/S) Series card VACT member 5: 0:Disable 1:Enable |
| 1.3.6.1.4.1.4756.20.111.20.1.82 | Columnfa5e1et100SnmpChannel1Remote | read-write | current | 5E1-ET100(T/S) Series card SNMP channel 0: 0:No use 1:Use |
| 1.3.6.1.4.1.4756.20.111.20.1.83 | Columnfa5e1et100SnmpChannel2Remote | read-write | current | 5E1-ET100(T/S) Series card SNMP channel 1: 0:No use 1:Use |
| 1.3.6.1.4.1.4756.20.111.20.1.84 | Columnfa5e1et100SnmpChannel3Remote | read-write | current | 5E1-ET100(T/S) Series card SNMP channel 3: 0:No use 1:Use |
| 1.3.6.1.4.1.4756.20.111.20.1.85 | Columnfa5e1et100SnmpChannel4Remote | read-write | current | 5E1-ET100(T/S) Series card SNMP channel 4: 0:No use 1:Use |
| 1.3.6.1.4.1.4756.20.111.20.1.86 | Columnfa5e1et100ErrSecRemote | read-only | current | 5E1-ET100(T/S) Series card, errored seconds of BERT result. |
| 1.3.6.1.4.1.4756.20.111.20.1.87 | Columnfa5e1et100ErrFreeSecRemote | read-only | current | 5E1-ET100(T/S) Series card, errored free seconds of BERT result. |
| 1.3.6.1.4.1.4756.20.111.20.1.88 | Columnfa5e1et100ServErrSecRemote | read-only | current | 5E1-ET100(T/S) Series card, severely errored seconds of BERT result. |
| 1.3.6.1.4.1.4756.20.111.20.1.89 | Columnfa5e1et100BertFunctionRemote | read-write | current | 5E1-ET100(T/S) Series card bert function: 0:Disable 1:Enable |
| 1.3.6.1.4.1.4756.20.111.20.1.90 | Columnfa5e1et100ClrBertDataRemote | read-write | current | 5E1-ET100(T/S) Series card bert data clear: 0:Normal 1:Clear |
| 1.3.6.1.4.1.4756.20.111.20.1.91 | Columnfa5e1et100RmonFunctionRemote | read-write | current | 5E1-ET100(T/S) Series RMON function : 0:Disable 1:Enable |
| 1.3.6.1.4.1.4756.20.111.20.1.92 | Columnfa5e1et100RmonTxRemote | read-only | current | 5E1-ET100(T/S) Series card RMON Tx counter. |
| 1.3.6.1.4.1.4756.20.111.20.1.93 | Columnfa5e1et100RmonRxRemote | read-only | current | 5E1-ET100(T/S) Series card RMON Rx counter. |
| 1.3.6.1.4.1.4756.20.111.20.1.94 | Columnfa5e1et100ClrRmonTxRemote | read-write | current | 5E1-ET100(T/S) Series card clear RMON Tx counter: 0:Normal 1:Clear |
| 1.3.6.1.4.1.4756.20.111.20.1.95 | Columnfa5e1et100ClrRmonRxRemote | read-write | current | 5E1-ET100(T/S) Series card clear RMON Rx counter: 0:Normal 1:Clear |
| 1.3.6.1.4.1.4756.20.111.20.1.96 | Columnfa5e1et100BertE1ChannelRemote | read-write | current | 5E1-ET100(T/S) Series card bert E1 channel number: 0:E1 channel 1 1:E1 channel 2 2:E1 channel 3 3:E1 channel 4 4:E1 channel 5 |
| 1.3.6.1.4.1.4756.20.111.20.1.97 | Columnfa5e1et100SfpRemote | read-only | current | 5E1-ET100(T/S) Series card, SFP existed: 0:No 1:Yes |
| 1.3.6.1.4.1.4756.20.111.20.1.98 | Columnfa5e1et100SfpVendorRemote | read-only | current | 5E1-ET100(T/S) Series card, Vendor name of SFP. |
| 1.3.6.1.4.1.4756.20.111.20.1.99 | Columnfa5e1et100SfpPartNoRemote | read-only | current | 5E1-ET100(T/S) Series card, Vendor part number of SFP. |
| 1.3.6.1.4.1.4756.20.111.20.1.100 | Columnfa5e1et100SfpFiberTypeRemote | read-only | current | 5E1-ET100(T/S) Series card, Fiber Type of SFP. |
| 1.3.6.1.4.1.4756.20.111.20.1.101 | Columnfa5e1et100SfpTxWaveLenRemote | read-only | current | 5E1-ET100(T/S) Series card, Tx Wave length of SFP. |
| 1.3.6.1.4.1.4756.20.111.20.1.102 | Columnfa5e1et100SfpRxWaveLenRemote | read-only | current | 5E1-ET100(T/S) Series card, Rx Wave length of SFP. |
| 1.3.6.1.4.1.4756.20.111.20.1.103 | Columnfa5e1et100SfpLinkLenRemote | read-only | current | 5E1-ET100(T/S) Series card, Link length of SFP. |
| 1.3.6.1.4.1.4756.20.111.20.1.104 | Columnfa5e1et100SfpModelIDRemote | read-only | current | 5E1-ET100(T/S) Series card, model ID of SFP. |
| 1.3.6.1.4.1.4756.20.111.20.1.105 | Columnfa5e1et100SfpVersionRemote | read-only | current | 5E1-ET100(T/S) Series card, the version of SFP. |
| 1.3.6.1.4.1.4756.20.111.20.1.106 | Columnfa5e1et100SfpModelTypeRemote | read-only | current | 5E1-ET100(T/S) Series card, model type of SFP. |
| 1.3.6.1.4.1.4756.20.111.20.1.107 | Columnfa5e1et100DDInformationRemote | read-only | current | 5E1-ET100(T/S) Series card, D/D information of SFP Supported: 0:No, 1:Yes |
| 1.3.6.1.4.1.4756.20.111.20.1.108 | Columnfa5e1et100DDRxSensRemote | read-only | current | 5E1-ET100(T/S) Series card, Sensitivity of D/D information. |
| 1.3.6.1.4.1.4756.20.111.20.1.109 | Columnfa5e1et100DDTxPowerRemote | read-only | current | 5E1-ET100(T/S) Series card, Tx power of D/D information. |
| 1.3.6.1.4.1.4756.20.111.20.1.110 | Columnfa5e1et100DDRxPowerRemote | read-only | current | 5E1-ET100(T/S) Series card, Rx power of D/D information. |
| 1.3.6.1.4.1.4756.20.111.20.1.111 | Columnfa5e1et100DDTempRemote | read-only | current | 5E1-ET100(T/S) Series card, Temperature of D/D information in degree C. |
| 1.3.6.1.4.1.4756.20.111.20.1.112 | Columnfa5e1et100DDBiasRemote | read-only | current | 5E1-ET100(T/S) Series card, BIAS of D/D information. |
| 1.3.6.1.4.1.4756.20.111.20.1.113 | Columnfa5e1et100DDVoltageRemote | read-only | current | 5E1-ET100(T/S) Series card, Voltage of D/D information. |
| 1.3.6.1.4.1.4756.20.111.20.1.114 | Columnfa5e1et100ChannelDefectRemote | read-write | current | 5E1-ET100(T/S) Series card Channel Defect: 0:Disable 4:1E-4 6:1E-6 |
| 1.3.6.1.4.1.4756.20.111.20.1.115 | Columnfa5e1et100LoopDetectionRemote | read-write | current | 5E1-ET100(T/S) Series card Loop Detection: 0:Disable 1:Enable |
| 1.3.6.1.4.1.4756.20.111.20.1.116 | Columnfa5e1et100LoopCh1Remote | read-only | current | 5E1-ET100(T/S) Series card E1 channel 1 Loop Check State: 0:No 1:Yes |
| 1.3.6.1.4.1.4756.20.111.20.1.117 | Columnfa5e1et100LoopCh2Remote | read-only | current | 5E1-ET100(T/S) Series card E1 channel 2 Loop Check State: 0:No 1:Yes |
| 1.3.6.1.4.1.4756.20.111.20.1.118 | Columnfa5e1et100LoopCh3Remote | read-only | current | 5E1-ET100(T/S) Series card E1 channel 3 Loop Check State: 0:No 1:Yes |
| 1.3.6.1.4.1.4756.20.111.20.1.119 | Columnfa5e1et100LoopCh4Remote | read-only | current | 5E1-ET100(T/S) Series card E1 channel 4 Loop Check State: 0:No 1:Yes |
| 1.3.6.1.4.1.4756.20.111.20.1.120 | Columnfa5e1et100LoopCh5Remote | read-only | current | 5E1-ET100(T/S) Series card E1 channel 5 Loop Check State: 0:No 1:Yes |
| 1.3.6.1.4.1.4756.20.111.20.1.121 | Columnfa5e1et100DefectCh1Remote | read-only | current | 5E1-ET100(T/S) Series card E1 channel 1 Defect Status: 0:No 1:Yes |
| 1.3.6.1.4.1.4756.20.111.20.1.122 | Columnfa5e1et100DefectCh2Remote | read-only | current | 5E1-ET100(T/S) Series card E1 channel 2 Defect Status: 0:No 1:Yes |
| 1.3.6.1.4.1.4756.20.111.20.1.123 | Columnfa5e1et100DefectCh3Remote | read-only | current | 5E1-ET100(T/S) Series card E1 channel 3 Defect Status: 0:No 1:Yes |
| 1.3.6.1.4.1.4756.20.111.20.1.124 | Columnfa5e1et100DefectCh4Remote | read-only | current | 5E1-ET100(T/S) Series card E1 channel 4 Defect Status: 0:No 1:Yes |
| 1.3.6.1.4.1.4756.20.111.20.1.125 | Columnfa5e1et100DefectCh5Remote | read-only | current | 5E1-ET100(T/S) Series card E1 channel 5 Defect Status: 0:No 1:Yes |
| 1.3.6.1.4.1.4756.20.111.20.1.126 | Columnfa5e1et100FxSignalRemote | read-only | current | 5E1-ET100(T/S) Series card Fiber signal detect(SD): 0:Fiber unplugged 1:Signal detected |
| 1.3.6.1.4.1.4756.20.111.20.1.127 | Columnfa5e1et100PortResetRemote | read-write | current | 5E1-ET100(T/S) Series card Port Reset: 0:Action 1:Off |
| 1.3.6.1.4.1.4756.20.111.20.1.128 | Columnfa5e1et100VLANModeRemote | read-write | current | 5E1-ET100(T/S) Series card VLAN mode: 0:MODE2 1:MODE1 |
| 1.3.6.1.4.1.4756.20.111.20.1.129 | Columnfa5e1et100ETagSelectEntryRemote | read-write | current | 5E1-ET100(T/S) Series card ETag select entry: |
| 1.3.6.1.4.1.4756.20.111.20.1.130 | Columnfa5e1et100ETagMethodRemote | read-write | current | 5E1-ET100(T/S) Series card ETag Method: 0: Intouch 1: Add Tag 2: Remove Tag |
| 1.3.6.1.4.1.4756.20.111.20.1.131 | Columnfa5e1et100VLANTableVID1Remote | read-write | current | 5E1-ET100(T/S) Series card VLAN Table: VLAN ID1 |
| 1.3.6.1.4.1.4756.20.111.20.1.132 | Columnfa5e1et100VLANTableVID2Remote | read-write | current | 5E1-ET100(T/S) Series card VLAN Table: VLAN ID2 |
| 1.3.6.1.4.1.4756.20.111.20.1.133 | Columnfa5e1et100VLANTableVID3Remote | read-write | current | 5E1-ET100(T/S) Series card VLAN Table: VLAN ID3 |
| 1.3.6.1.4.1.4756.20.111.20.1.134 | Columnfa5e1et100VLANTableVID4Remote | read-write | current | 5E1-ET100(T/S) Series card VLAN Table: VLAN ID4 |
| 1.3.6.1.4.1.4756.20.111.20.1.135 | Columnfa5e1et100VLANTableVID5Remote | read-write | current | 5E1-ET100(T/S) Series card VLAN Table: VLAN ID5 |
| 1.3.6.1.4.1.4756.20.111.20.1.136 | Columnfa5e1et100VLANTableVID6Remote | read-write | current | 5E1-ET100(T/S) Series card VLAN Table: VLAN ID6 |
| 1.3.6.1.4.1.4756.20.111.20.1.137 | Columnfa5e1et100VLANTableVID7Remote | read-write | current | 5E1-ET100(T/S) Series card VLAN Table: VLAN ID7 |
| 1.3.6.1.4.1.4756.20.111.20.1.138 | Columnfa5e1et100VLANTableVID8Remote | read-write | current | 5E1-ET100(T/S) Series card VLAN Table: VLAN ID8 |
| 1.3.6.1.4.1.4756.20.111.20.1.139 | Columnfa5e1et100VLANTableVID9Remote | read-write | current | 5E1-ET100(T/S) Series card VLAN Table: VLAN ID9 |
| 1.3.6.1.4.1.4756.20.111.20.1.140 | Columnfa5e1et100VLANTableVID10Remote | read-write | current | 5E1-ET100(T/S) Series card VLAN Table: VLAN ID10 |
| 1.3.6.1.4.1.4756.20.111.20.1.141 | Columnfa5e1et100VLANTableVID11Remote | read-write | current | 5E1-ET100(T/S) Series card VLAN Table: VLAN ID11 |
| 1.3.6.1.4.1.4756.20.111.20.1.142 | Columnfa5e1et100VLANTableVID12Remote | read-write | current | 5E1-ET100(T/S) Series card VLAN Table: VLAN ID12 |
| 1.3.6.1.4.1.4756.20.111.20.1.143 | Columnfa5e1et100VLANTableVID13Remote | read-write | current | 5E1-ET100(T/S) Series card VLAN Table: VLAN ID13 |
| 1.3.6.1.4.1.4756.20.111.20.1.144 | Columnfa5e1et100VLANTableVID14Remote | read-write | current | 5E1-ET100(T/S) Series card VLAN Table: VLAN ID14 |
| 1.3.6.1.4.1.4756.20.111.20.1.145 | Columnfa5e1et100VLANTableVID15Remote | read-write | current | 5E1-ET100(T/S) Series card VLAN Table: VLAN ID15 |
| 1.3.6.1.4.1.4756.20.111.20.1.146 | Columnfa5e1et100VLANTableVID16Remote | read-write | current | 5E1-ET100(T/S) Series card VLAN Table: VLAN ID16 |
| 1.3.6.1.4.1.4756.20.120 | Nodef155MSCards | |||
| 1.3.6.1.4.1.4756.20.120.20 | Tablef155MSTable | not-accessible | current | A list of local FRM220-155MS card entries. The number of entries is f155MS-No. |
| 1.3.6.1.4.1.4756.20.120.20.1 | Rowf155MSEntry | not-accessible | current | An entry containing management information applicable to a particular local FRM220-155MS card. |
| 1.3.6.1.4.1.4756.20.120.20.1.1 | Columnf155MSChassisIndex | read-only | current | A unique value for each local card. It is the chassis location number. |
| 1.3.6.1.4.1.4756.20.120.20.1.2 | Columnf155MSSlotIndex | read-only | current | A unique value for each local card. It is the slot location number. |
| 1.3.6.1.4.1.4756.20.120.20.1.3 | Columnf155MSCardHWVer | read-only | current | Local FRM220-f155MS card hardware version x.xxx |
| 1.3.6.1.4.1.4756.20.120.20.1.4 | Columnf155MSCardFWVer | read-only | current | Local FRM220-f155MS card firmware version x.xxx |
| 1.3.6.1.4.1.4756.20.120.20.1.5 | Columnf155MSCardCPLDVer | read-only | current | Local FRM220-f155MS card CPLD version x.xxx |
| 1.3.6.1.4.1.4756.20.120.20.1.6 | Columnf155MSCardFPGAVer | read-only | current | Local FRM220-f155MS card FPGA version x.xxx |
| 1.3.6.1.4.1.4756.20.120.20.1.7 | Columnf155MSPortActive | read-write | current | Local FRM220-f155MS card active: 0:Inactive 1:Active |
| 1.3.6.1.4.1.4756.20.120.20.1.8 | Columnf155MSFxLLink | read-only | current | Local FRM220-155MS card fiber of line side link status: 0:Down 1:Up |
| 1.3.6.1.4.1.4756.20.120.20.1.9 | Columnf155MSFxCLink | read-only | current | Local FRM220-155MS card fiber of client side link status: 0:Down 1:Up |
| 1.3.6.1.4.1.4756.20.120.20.1.10 | Columnf155MSLnLBTest | read-write | current | Force local FRM220-155MS card to do fiber of line side LoopBack testing: 0:Off 1:Action |
| 1.3.6.1.4.1.4756.20.120.20.1.11 | Columnf155MSCliLBTest | read-write | current | Force local FRM220-155MS card to do fiber of client side LoopBack testing: 0:Off 1:Action |
| 1.3.6.1.4.1.4756.20.120.20.1.12 | Columnf155MSPortReset | read-write | current | Force remote FRM220-155MS card to reset mode: 0:Off 1:Action |
| 1.3.6.1.4.1.4756.20.120.20.1.13 | Columnf155MSSetDefault | read-write | current | Force remote FRM220-155MS card to default status: 0:Off 1:Action |
| 1.3.6.1.4.1.4756.20.120.20.1.14 | Columnf155MSLfpMode | read-write | current | Local FRM220-155MS card Link Fault Pass-through mode: 0:Disable 1:Enable |
| 1.3.6.1.4.1.4756.20.120.20.1.15 | Columnf155MSAlsMode | read-write | current | Local FRM220-155MS card Auto Laser Shutdown mode: 0:Disable 1:Enable |
| 1.3.6.1.4.1.4756.20.120.20.1.16 | Columnf155MSFxLDD | read-only | current | Local FRM220-155MS card line side fiber Digital Diagnostic function: 0:No 1:Yes |
| 1.3.6.1.4.1.4756.20.120.20.1.17 | Columnf155MSFxCDD | read-only | current | Local FRM220-155MS card client side fiber Digital Diagnostic function: 0:No 1:Yes |
| 1.3.6.1.4.1.4756.20.120.20.1.18 | Columnf155MSLddVendor | read-only | current | Local FRM220-155MS card fiber D/D information: Vendor name |
| 1.3.6.1.4.1.4756.20.120.20.1.19 | Columnf155MSLddPartNo | read-only | current | Local FRM220-155MS card fiber D/D information: Vendor part number |
| 1.3.6.1.4.1.4756.20.120.20.1.20 | Columnf155MSLddFiberType | read-only | current | Local FRM220-155MS card fiber D/D information: Fiber Type |
| 1.3.6.1.4.1.4756.20.120.20.1.21 | Columnf155MSLddWaveLen | read-only | current | Local FRM220-155MS card fiber D/D information: Wave length |
| 1.3.6.1.4.1.4756.20.120.20.1.22 | Columnf155MSLddWaveLen2 | read-only | current | Local FRM220-155MS card fiber D/D information: Wave length 2 |
| 1.3.6.1.4.1.4756.20.120.20.1.23 | Columnf155MSLddLinkLen | read-only | current | Local FRM220-155MS card fiber D/D information: Link length |
| 1.3.6.1.4.1.4756.20.120.20.1.24 | Columnf155MSLddLenUnit | read-only | current | Local FRM220-155MS card fiber D/D information: Length Unit |
| 1.3.6.1.4.1.4756.20.120.20.1.25 | Columnf155MSLddStatus | read-only | current | Local FRM220-155MS card fiber D/D information: Status Support |
| 1.3.6.1.4.1.4756.20.120.20.1.26 | Columnf155MSLddRxSens | read-only | current | Local FRM220-155MS card fiber D/D information: Rx Sensitivity |
| 1.3.6.1.4.1.4756.20.120.20.1.27 | Columnf155MSLddTxPWR | read-only | current | Local FRM220-155MS card fiber D/D information: Tx power |
| 1.3.6.1.4.1.4756.20.120.20.1.28 | Columnf155MSLddRxPWR | read-only | current | Local FRM220-155MS card fiber D/D information: Rx power |
| 1.3.6.1.4.1.4756.20.120.20.1.29 | Columnf155MSLddTemp | read-only | current | Local FRM220-155MS card fiber D/D information: Temperature in degree C |
| 1.3.6.1.4.1.4756.20.120.20.1.30 | Columnf155MSLddPWRMargin | read-only | current | Local FRM220-155MS card fiber D/D information: Power margin |
| 1.3.6.1.4.1.4756.20.120.20.1.31 | Columnf155MSLddPWRLoss | read-only | current | Local FRM220-155MS card fiber D/D information: Power loss |
| 1.3.6.1.4.1.4756.20.120.20.1.32 | Columnf155MSCddVendor | read-only | current | Local FRM220-155MS card fiber D/D information: Vendor name |
| 1.3.6.1.4.1.4756.20.120.20.1.33 | Columnf155MSCddPartNo | read-only | current | Local FRM220-155MS card fiber D/D information: Vendor part number |
| 1.3.6.1.4.1.4756.20.120.20.1.34 | Columnf155MSCddFiberType | read-only | current | Local FRM220-155MS card fiber D/D information: Fiber Type |
| 1.3.6.1.4.1.4756.20.120.20.1.35 | Columnf155MSCddWaveLen | read-only | current | Local FRM220-155MS card fiber D/D information: Wave length |
| 1.3.6.1.4.1.4756.20.120.20.1.36 | Columnf155MSCddWaveLen2 | read-only | current | Local FRM220-155MS card fiber D/D information: Wave length 2 |
| 1.3.6.1.4.1.4756.20.120.20.1.37 | Columnf155MSCddLinkLen | read-only | current | Local FRM220-155MS card fiber D/D information: Link length |
| 1.3.6.1.4.1.4756.20.120.20.1.38 | Columnf155MSCddLenUnit | read-only | current | Local FRM220-155MS card fiber D/D information: Length Unit |
| 1.3.6.1.4.1.4756.20.120.20.1.39 | Columnf155MSCddStatus | read-only | current | Local FRM220-155MS card fiber D/D information: Status Support |
| 1.3.6.1.4.1.4756.20.120.20.1.40 | Columnf155MSCddRxSens | read-only | current | Local FRM220-155MS card fiber D/D information: Rx Sensitivity |
| 1.3.6.1.4.1.4756.20.120.20.1.41 | Columnf155MSCddTxPWR | read-only | current | Local FRM220-155MS card fiber D/D information: Tx power |
| 1.3.6.1.4.1.4756.20.120.20.1.42 | Columnf155MSCddRxPWR | read-only | current | Local FRM220-155MS card fiber D/D information: Rx power |
| 1.3.6.1.4.1.4756.20.120.20.1.43 | Columnf155MSCddTemp | read-only | current | Local FRM220-155MS card fiber D/D information: Temperature in degree C |
| 1.3.6.1.4.1.4756.20.120.20.1.44 | Columnf155MSCddPWRMargin | read-only | current | Local FRM220-155MS card fiber D/D information: Power margin |
| 1.3.6.1.4.1.4756.20.120.20.1.45 | Columnf155MSCddPWRLoss | read-only | current | Local FRM220-155MS card fiber D/D information: Power loss |
| 1.3.6.1.4.1.4756.20.130 | Nodef1000TSCards | |||
| 1.3.6.1.4.1.4756.20.130.20 | Tablef1000TSTable | not-accessible | current | A list of local FRM220-1000TS card entries. The number of entries is f1000TS-No-L. |
| 1.3.6.1.4.1.4756.20.130.20.1 | Rowf1000TSEntry | not-accessible | current | An entry containing management information applicable to a particular local FRM220-1000TS card. |
| 1.3.6.1.4.1.4756.20.130.20.1.1 | Columnf1000TSChassisIndex | read-only | current | A unique value for each local card. It is the chassis location number. |
| 1.3.6.1.4.1.4756.20.130.20.1.2 | Columnf1000TSSlotIndex | read-only | current | A unique value for each local card. It is the slot location number. |
| 1.3.6.1.4.1.4756.20.130.20.1.3 | Columnf1000TSCardHWVer | read-only | current | Local FRM220-1000TS card hardware version x.xxx |
| 1.3.6.1.4.1.4756.20.130.20.1.4 | Columnf1000TSCardFWVer | read-only | current | Local FRM220-1000TS card firmware version x.xxx |
| 1.3.6.1.4.1.4756.20.130.20.1.5 | Columnf1000TSCardCPLDVer | read-only | current | Local FRM220-1000TS card CPLD version x.xxx |
| 1.3.6.1.4.1.4756.20.130.20.1.6 | Columnf1000TSCardFPGAVer | read-only | current | Local FRM220-1000TS card FPGA version x.xxx |
| 1.3.6.1.4.1.4756.20.130.20.1.7 | Columnf1000TSModel | read-only | current | Local CardType: 0:FRM220-1000TS 1:FRM220-1000T |
| 1.3.6.1.4.1.4756.20.130.20.1.8 | Columnf1000TSPortActive | read-write | current | Local FRM220-1000TS card active: 0:Inactive 1:Active |
| 1.3.6.1.4.1.4756.20.130.20.1.9 | Columnf1000TSUtpLink | read-only | current | Local FRM220-1000TS card UTP link status: 0:Down 1:Up |
| 1.3.6.1.4.1.4756.20.130.20.1.10 | Columnf1000TSUtpRxAct | read-only | current | Local FRM220-1000TS card UTP receive active status: 0:Off 1:On |
| 1.3.6.1.4.1.4756.20.130.20.1.11 | Columnf1000TSUtpSpeed | read-only | current | Local FRM220-1000TS card UTP speed: 0:1000MHz |
| 1.3.6.1.4.1.4756.20.130.20.1.12 | Columnf1000TSUtpDuplex | read-write | current | Local FRM220-1000TS card UTP duplex: 0:Half duplex mode 1:Full duplex mode |
| 1.3.6.1.4.1.4756.20.130.20.1.13 | Columnf1000TSFxLink | read-only | current | Local FRM220-1000TS card fiber link status: 0:Down 1:Up |
| 1.3.6.1.4.1.4756.20.130.20.1.14 | Columnf1000TSFxRxAct | read-only | current | Local FRM220-1000TS card fiber receiver active status: 0:Off 1:On |
| 1.3.6.1.4.1.4756.20.130.20.1.15 | Columnf1000TSFxNego | read-write | current | Local FRM220-1000TS card fiber negotiation: 0:Force 1:Auto |
| 1.3.6.1.4.1.4756.20.130.20.1.16 | Columnf1000TSFxSpeed | read-only | current | Local FRM220-1000TS card fiber speed: 0:Speed 1000 |
| 1.3.6.1.4.1.4756.20.130.20.1.17 | Columnf1000TSFxRemoPWRAb | read-only | current | Local FRM220-1000TS card fiber Remote Power status: 0:Abnormal 1:OK |
| 1.3.6.1.4.1.4756.20.130.20.1.18 | Columnf1000TSPortReset | read-write | current | Force local FRM220-1000TS card to reset mode: 0:Off 1:Action |
| 1.3.6.1.4.1.4756.20.130.20.1.19 | Columnf1000TSLfpMode | read-write | current | Local FRM220-1000TS card Link Fault Pass-through mode: 0:Disable 1:Enable |
| 1.3.6.1.4.1.4756.20.130.20.1.20 | Columnf1000TSAlsMode | read-write | current | Local FRM220-1000TS card Auto Laser Shutdown mode: 0:Disable 1:Enable |
| 1.3.6.1.4.1.4756.20.130.20.1.21 | Columnf1000TSFxDD | read-only | current | Local FRM220-1000TS card fiber Digital Diagnostic function: 0:No 1:Yes |
| 1.3.6.1.4.1.4756.20.130.20.1.22 | Columnf1000TSDDVendor | read-only | current | Local FRM220-1000TS card fiber D/D information: Vendor name |
| 1.3.6.1.4.1.4756.20.130.20.1.23 | Columnf1000TSDDPartNo | read-only | current | Local FRM220-1000TS card fiber D/D information: Vendor part number |
| 1.3.6.1.4.1.4756.20.130.20.1.24 | Columnf1000TSDDFiberType | read-only | current | Local FRM220-1000TS card fiber D/D information: Fiber Type |
| 1.3.6.1.4.1.4756.20.130.20.1.25 | Columnf1000TSDDWaveLen | read-only | current | Local FRM220-1000TS card fiber D/D information: Wave length |
| 1.3.6.1.4.1.4756.20.130.20.1.26 | Columnf1000TSDDWaveLen2 | read-only | current | Local FRM220-1000TS card fiber D/D information: Wave length 2 |
| 1.3.6.1.4.1.4756.20.130.20.1.27 | Columnf1000TSDDLinkLen | read-only | current | Local FRM220-1000TS card fiber D/D information: Link length |
| 1.3.6.1.4.1.4756.20.130.20.1.28 | Columnf1000TSDDLenUnit | read-only | current | Local FRM220-1000TS card fiber D/D information: Length Unit |
| 1.3.6.1.4.1.4756.20.130.20.1.29 | Columnf1000TSDDStatus | read-only | current | Local FRM220-1000TS card fiber D/D information: Status Support |
| 1.3.6.1.4.1.4756.20.130.20.1.30 | Columnf1000TSDDRxSens | read-only | current | Local FRM220-1000TS card fiber D/D information: Rx Sensitivity |
| 1.3.6.1.4.1.4756.20.130.20.1.31 | Columnf1000TSDDTxPWR | read-only | current | Local FRM220-1000TS card fiber D/D information: Tx power |
| 1.3.6.1.4.1.4756.20.130.20.1.32 | Columnf1000TSDDRxPWR | read-only | current | Local FRM220-1000TS card fiber D/D information: Rx power |
| 1.3.6.1.4.1.4756.20.130.20.1.33 | Columnf1000TSDDTemp | read-only | current | Local FRM220-1000TS card fiber D/D information: Temperature in degree C |
| 1.3.6.1.4.1.4756.20.130.20.1.34 | Columnf1000TSDDPWRMargin | read-only | current | Local FRM220-1000TS card fiber D/D information: Power margin |
| 1.3.6.1.4.1.4756.20.130.20.1.35 | Columnf1000TSDDPWRLoss | read-only | current | Local FRM220-1000TS card fiber D/D information: Power loss |
| 1.3.6.1.4.1.4756.20.140 | Nodef3R27GCards | |||
| 1.3.6.1.4.1.4756.20.140.20 | Tablef3R27GTable | not-accessible | current | A list of local FRM220-3R27G card entries. The number of entries is f3R27G-No-L. |
| 1.3.6.1.4.1.4756.20.140.20.1 | Rowf3R27GEntry | not-accessible | current | An entry containing management information applicable to a particular local FRM220-3R27G card. |
| 1.3.6.1.4.1.4756.20.140.20.1.1 | Columnf3R27GChassisIndex | read-only | current | A unique value for each local card. It is the chassis location number. |
| 1.3.6.1.4.1.4756.20.140.20.1.2 | Columnf3R27GSlotIndex | read-only | current | A unique value for each local card. It is the slot location number. |
| 1.3.6.1.4.1.4756.20.140.20.1.3 | Columnf3R27GCardHWVer | read-only | current | Local FRM220-3R27G card hardware version x.xxx |
| 1.3.6.1.4.1.4756.20.140.20.1.4 | Columnf3R27GCardFWVer | read-only | current | Local FRM220-3R27G card firmware version x.xxx |
| 1.3.6.1.4.1.4756.20.140.20.1.5 | Columnf3R27GCardCPLDVer | read-only | current | Local FRM220-3R27G card CPLD version x.xxx |
| 1.3.6.1.4.1.4756.20.140.20.1.6 | Columnf3R27GCardFPGAVer | read-only | current | Local FRM220-3R27G card FPGA version x.xxx |
| 1.3.6.1.4.1.4756.20.140.20.1.7 | Columnf3R27GModel | read-only | current | Local CardType: 0:FRM220-3R27G/2S 1:FRM220-3R27G/3S |
| 1.3.6.1.4.1.4756.20.140.20.1.8 | Columnf3R27GDeviceActive | read-write | current | Local FRM220-3R27G card active: 0:Inactive 1:Active |
| 1.3.6.1.4.1.4756.20.140.20.1.9 | Columnf3R27GFx1Link | read-only | current | Local FRM220-3R27G card Fiber1 link status: 0:Down 1:Up |
| 1.3.6.1.4.1.4756.20.140.20.1.10 | Columnf3R27GFx2Link | read-only | current | Local FRM220-3R27G card Fiber2 link status: 0:Down 1:Up |
| 1.3.6.1.4.1.4756.20.140.20.1.11 | Columnf3R27GFx3Link | read-only | current | Local FRM220-3R27G card Fiber3 link status: 0:Down 1:Up |
| 1.3.6.1.4.1.4756.20.140.20.1.12 | Columnf3R27GFx1TxFail | read-only | current | Local FRM220-3R27G card Fiber1 Transceiver Tx Detect: 0:Normal 1:Fail |
| 1.3.6.1.4.1.4756.20.140.20.1.13 | Columnf3R27GFx2TxFail | read-only | current | Local FRM220-3R27G card Fiber2 Transceiver Tx Detect: 0:Normal 1:Fail |
| 1.3.6.1.4.1.4756.20.140.20.1.14 | Columnf3R27GFx3TxFail | read-only | current | Local FRM220-3R27G card Fiber3 Transceiver Tx Detect: 0:Normal 1:Fail |
| 1.3.6.1.4.1.4756.20.140.20.1.15 | Columnf3R27GFx1AlsMode | read-write | current | Local FRM220-3R27G card Fiber1 Auto Laser Showdown: 0:Disable 1:Enable |
| 1.3.6.1.4.1.4756.20.140.20.1.16 | Columnf3R27GFx2AlsMode | read-write | current | Local FRM220-3R27G card Fiber2 Auto Laser Showdown: 0:Disable 1:Enable |
| 1.3.6.1.4.1.4756.20.140.20.1.17 | Columnf3R27GFx3AlsMode | read-write | current | Local FRM220-3R27G card Fiber3 Auto Laser Showdown: 0:Disable 1:Enable |
| 1.3.6.1.4.1.4756.20.140.20.1.18 | Columnf3R27GPortReset | read-write | current | Force local FRM220-3R27G card to reset mode: 0:Off 1:Action |
| 1.3.6.1.4.1.4756.20.140.20.1.19 | Columnf3R27GActivePath | read-write | current | Local FRM220-3R27G card Active Protection Path: 0:Primary 1:Secondary |
| 1.3.6.1.4.1.4756.20.140.20.1.20 | Columnf3R27GOpticFxPro | read-write | current | Local FRM220-3R27G card Optic Fiber Protection: 0:OFF 1:ON |
| 1.3.6.1.4.1.4756.20.140.20.1.21 | Columnf3R27GLbsetting | read-write | current | Local FRM220-3R27G card Loopback Test: 0:Disable 1:Line side enable 2:Client side enable 3:Line and Client enable |
| 1.3.6.1.4.1.4756.20.140.20.1.22 | Columnf3R27GLossPropagation | read-write | current | Local FRM220-3R27G card Link Fault Pass-through: 0:Disable 1:Enable |
| 1.3.6.1.4.1.4756.20.140.20.1.23 | Columnf3R27GBaudRate | read-write | current | Local FRM220-3R27G card Auto Select Client Master: 0:E3 1:DS3 2:OC-1 3:Fast Ethernet 4:OC-3/STM-1 5:OC-12/STM-4 6:Fiber Channel-1 7:OC-24 8:Giga ethernet 9:HD-… |
| 1.3.6.1.4.1.4756.20.140.20.1.24 | Columnf3R27GFx1DD | read-only | current | Local FRM220-3R27G card fiber Digital Diagnostic function: 0:No 1:Yes |
| 1.3.6.1.4.1.4756.20.140.20.1.25 | Columnf3R27GFx1DDVendor | read-only | current | Local FRM220-3R27G card fiber D/D information: Vendor name |
| 1.3.6.1.4.1.4756.20.140.20.1.26 | Columnf3R27GFx1DDPartNo | read-only | current | Local FRM220-3R27G card fiber D/D information: Vendor part number |
| 1.3.6.1.4.1.4756.20.140.20.1.27 | Columnf3R27GFx1DDFiberType | read-only | current | Local FRM220-3R27G card fiber D/D information: Fiber Type |
| 1.3.6.1.4.1.4756.20.140.20.1.28 | Columnf3R27GFx1DDWaveLen | read-only | current | Local FRM220-3R27G card fiber D/D information: Wave length |
| 1.3.6.1.4.1.4756.20.140.20.1.29 | Columnf3R27GFx1DDWaveLen2 | read-only | current | Local FRM220-3R27G card fiber D/D information: Wave length 2 |
| 1.3.6.1.4.1.4756.20.140.20.1.30 | Columnf3R27GFx1DDLinkLen | read-only | current | Local FRM220-3R27G card fiber D/D information: Link length |
| 1.3.6.1.4.1.4756.20.140.20.1.31 | Columnf3R27GFx1DDLenUnit | read-only | current | Local FRM220-3R27G card fiber D/D information: Length Unit |
| 1.3.6.1.4.1.4756.20.140.20.1.32 | Columnf3R27GFx1DDStatus | read-only | current | Local FRM220-3R27G card fiber D/D information: Status Support |
| 1.3.6.1.4.1.4756.20.140.20.1.33 | Columnf3R27GFx1DDRxSens | read-only | current | Local FRM220-3R27G card fiber D/D information: Rx Sensitivity |
| 1.3.6.1.4.1.4756.20.140.20.1.34 | Columnf3R27GFx1DDTxPWR | read-only | current | Local FRM220-3R27G card fiber D/D information: Tx power |
| 1.3.6.1.4.1.4756.20.140.20.1.35 | Columnf3R27GFx1DDRxPWR | read-only | current | Local FRM220-3R27G card fiber D/D information: Rx power |
| 1.3.6.1.4.1.4756.20.140.20.1.36 | Columnf3R27GFx1DDTemp | read-only | current | Local FRM220-3R27G card fiber D/D information: Temperature in degree C |
| 1.3.6.1.4.1.4756.20.140.20.1.37 | Columnf3R27GFx1DDPWRMargin | read-only | current | Local FRM220-3R27G card fiber D/D information: Power margin |
| 1.3.6.1.4.1.4756.20.140.20.1.38 | Columnf3R27GFx2DD | read-only | current | Local FRM220-3R27G card fiber2 Digital Diagnostic function: 0:No 1:Yes |
| 1.3.6.1.4.1.4756.20.140.20.1.39 | Columnf3R27GFx2DDVendor | read-only | current | Local FRM220-3R27G card fiber2 D/D information: Vendor name |
| 1.3.6.1.4.1.4756.20.140.20.1.40 | Columnf3R27GFx2DDPartNo | read-only | current | Local FRM220-3R27G card fiber2 D/D information: Vendor part number |
| 1.3.6.1.4.1.4756.20.140.20.1.41 | Columnf3R27GFx2DDFiberType | read-only | current | Local FRM220-3R27G card fiber2 D/D information: Fiber Type |
| 1.3.6.1.4.1.4756.20.140.20.1.42 | Columnf3R27GFx2DDWaveLen | read-only | current | Local FRM220-3R27G card fiber2 D/D information: Wave length |
| 1.3.6.1.4.1.4756.20.140.20.1.43 | Columnf3R27GFx2DDWaveLen2 | read-only | current | Local FRM220-3R27G card fiber2 D/D information: Wave length 2 |
| 1.3.6.1.4.1.4756.20.140.20.1.44 | Columnf3R27GFx2DDLinkLen | read-only | current | Local FRM220-3R27G card fiber2 D/D information: Link length |
| 1.3.6.1.4.1.4756.20.140.20.1.45 | Columnf3R27GFx2DDLenUnit | read-only | current | Local FRM220-3R27G card fiber2 D/D information: Length Unit |
| 1.3.6.1.4.1.4756.20.140.20.1.46 | Columnf3R27GFx2DDStatus | read-only | current | Local FRM220-3R27G card fiber2 D/D information: Status Support |
| 1.3.6.1.4.1.4756.20.140.20.1.47 | Columnf3R27GFx2DDRxSens | read-only | current | Local FRM220-3R27G card fiber2 D/D information: Rx Sensitivity |
| 1.3.6.1.4.1.4756.20.140.20.1.48 | Columnf3R27GFx2DDTxPWR | read-only | current | Local FRM220-3R27G card fiber2 D/D information: Tx power |
| 1.3.6.1.4.1.4756.20.140.20.1.49 | Columnf3R27GFx2DDRxPWR | read-only | current | Local FRM220-3R27G card fiber2 D/D information: Rx power |
| 1.3.6.1.4.1.4756.20.140.20.1.50 | Columnf3R27GFx2DDTemp | read-only | current | Local FRM220-3R27G card fiber2 D/D information: Temperature in degree C |
| 1.3.6.1.4.1.4756.20.140.20.1.51 | Columnf3R27GFx2DDPWRMargin | read-only | current | Local FRM220-3R27G card fiber2 D/D information: Power margin |
| 1.3.6.1.4.1.4756.20.140.20.1.52 | Columnf3R27GFx3DD | read-only | current | Local FRM220-3R27G card fiber3 Digital Diagnostic function: 0:No 1:Yes |
| 1.3.6.1.4.1.4756.20.140.20.1.53 | Columnf3R27GFx3DDVendor | read-only | current | Local FRM220-3R27G card fiber3 D/D information: Vendor name |
| 1.3.6.1.4.1.4756.20.140.20.1.54 | Columnf3R27GFx3DDPartNo | read-only | current | Local FRM220-3R27G card fiber3 D/D information: Vendor part number |
| 1.3.6.1.4.1.4756.20.140.20.1.55 | Columnf3R27GFx3DDFiberType | read-only | current | Local FRM220-3R27G card fiber3 D/D information: Fiber Type |
| 1.3.6.1.4.1.4756.20.140.20.1.56 | Columnf3R27GFx3DDWaveLen | read-only | current | Local FRM220-3R27G card fiber3 D/D information: Wave length |
| 1.3.6.1.4.1.4756.20.140.20.1.57 | Columnf3R27GFx3DDWaveLen2 | read-only | current | Local FRM220-3R27G card fiber3 D/D information: Wave length 2 |
| 1.3.6.1.4.1.4756.20.140.20.1.58 | Columnf3R27GFx3DDLinkLen | read-only | current | Local FRM220-3R27G card fiber3 D/D information: Link length |
| 1.3.6.1.4.1.4756.20.140.20.1.59 | Columnf3R27GFx3DDLenUnit | read-only | current | Local FRM220-3R27G card fiber3 D/D information: Length Unit |
| 1.3.6.1.4.1.4756.20.140.20.1.60 | Columnf3R27GFx3DDStatus | read-only | current | Local FRM220-3R27G card fiber3 D/D information: Status Support |
| 1.3.6.1.4.1.4756.20.140.20.1.61 | Columnf3R27GFx3DDRxSens | read-only | current | Local FRM220-3R27G card fiber3 D/D information: Rx Sensitivity |
| 1.3.6.1.4.1.4756.20.140.20.1.62 | Columnf3R27GFx3DDTxPWR | read-only | current | Local FRM220-3R27G card fiber3 D/D information: Tx power |
| 1.3.6.1.4.1.4756.20.140.20.1.63 | Columnf3R27GFx3DDRxPWR | read-only | current | Local FRM220-3R27G card fiber3 D/D information: Rx power |
| 1.3.6.1.4.1.4756.20.140.20.1.64 | Columnf3R27GFx3DDTemp | read-only | current | Local FRM220-3R27G card fiber3 D/D information: Temperature in degree C |
| 1.3.6.1.4.1.4756.20.140.20.1.65 | Columnf3R27GFx3DDPWRMargin | read-only | current | Local FRM220-3R27G card fiber3 D/D information: Power margin |
| 1.3.6.1.4.1.4756.20.140.20.1.66 | Columnf3R27GFx1LinkAlarm | read-write | current | Local FRM220-3R27G card fiber 1 Link Alarm 0:Disable 1:Enable |
| 1.3.6.1.4.1.4756.20.140.20.1.67 | Columnf3R27GFx2LinkAlarm | read-write | current | Local FRM220-3R27G card fiber 2 Link Alarm 0:Disable 1:Enable |
| 1.3.6.1.4.1.4756.20.140.20.1.68 | Columnf3R27GFx3LinkAlarm | read-write | current | Local FRM220-3R27G card fiber 3 Link Alarm 0:Disable 1:Enable |
| 1.3.6.1.4.1.4756.20.150 | Nodef1000EASLocalCards | |||
| 1.3.6.1.4.1.4756.20.150.40 | Tablef1000EASLocalTable | not-accessible | current | A list of local frm220-1000EAS card entries. The number of entries is f1000EAS-NoLocal. |
| 1.3.6.1.4.1.4756.20.150.40.1 | Rowf1000EASLocalEntry | not-accessible | current | An entry containing management information applicable to a particular local FRM-1000EAS card. |
| 1.3.6.1.4.1.4756.20.150.40.1.1 | Columnf1000EASChassisIndexLocal | read-only | current | A unique value for each local card. It is the chassis location number. |
| 1.3.6.1.4.1.4756.20.150.40.1.2 | Columnf1000EASSlotIndexLocal | read-only | current | A unique value for each local card. It is the slot location number. |
| 1.3.6.1.4.1.4756.20.150.40.1.3 | Columnf1000EASCardHWVerLocal | read-only | current | Local device card hardware version x.xxx |
| 1.3.6.1.4.1.4756.20.150.40.1.4 | Columnf1000EASCardFWVerLocal | read-only | current | Local device card firmware version x.xxx |
| 1.3.6.1.4.1.4756.20.150.40.1.5 | Columnf1000EASCardCPLDVerLocal | read-only | current | Local device card CPLD version x.xxx |
| 1.3.6.1.4.1.4756.20.150.40.1.6 | Columnf1000EASCardFPGAVerLocal | read-only | current | Local device card FPGA version x.xxx |
| 1.3.6.1.4.1.4756.20.150.40.1.7 | Columnf1000EASModelLocal | read-only | current | Local frm220 f1000EAS Serial Type |
| 1.3.6.1.4.1.4756.20.150.40.1.8 | Columnf1000EASFx1LinkLocal | read-only | current | Local device card fiber port 1 link status: 0:Down 1:Up |
| 1.3.6.1.4.1.4756.20.150.40.1.9 | Columnf1000EASFx1OAMLoopedLocal | read-only | current | Local device card fiber port 1 OAM looped: 0:Off 1:on |
| 1.3.6.1.4.1.4756.20.150.40.1.10 | Columnf1000EASFx1LBTestLocal | read-write | current | Force remote device card to do fiber port 1 LoopBack testing: 0:Off 1:Action |
| 1.3.6.1.4.1.4756.20.150.40.1.11 | Columnf1000EASFx1OAMRLBStatusLocal | read-only | current | Remote device card fiber port 1 LoopBack testing status: 0:Off 1:Ok 2:Fail |
| 1.3.6.1.4.1.4756.20.150.40.1.12 | Columnf1000EASFx1RemoPwrAbLocal | read-only | current | Local device card fiber port 1 Remote Power status: 0:Abnormal 1:OK 2:None |
| 1.3.6.1.4.1.4756.20.150.40.1.13 | Columnf1000EASFx2LinkLocal | read-only | current | Local device card fiber port 2 link status: 0:Down 1:Up |
| 1.3.6.1.4.1.4756.20.150.40.1.14 | Columnf1000EASFx2OAMLoopedLocal | read-only | current | Local device card fiber port 2 OAM looped: 0:Off 1:on |
| 1.3.6.1.4.1.4756.20.150.40.1.15 | Columnf1000EASFx2LBTestLocal | read-write | current | Force remote device card to do fiber port 2 LoopBack testing: 0:Off 1:Action |
| 1.3.6.1.4.1.4756.20.150.40.1.16 | Columnf1000EASFx2OAMRLBStatusLocal | read-only | current | Remote device card fiber port 1 LoopBack testing status: 0:Off 1:Ok 2:Fail |
| 1.3.6.1.4.1.4756.20.150.40.1.17 | Columnf1000EASFx2RemoPwrAbLocal | read-only | current | Local device card fiber port 2 Remote Power status: 0:Abnormal 1:OK 2:None |
| 1.3.6.1.4.1.4756.20.150.40.1.18 | Columnf1000EASUtp1LinkLocal | read-only | current | Local device card UTP port 3 link status: 0:Down 1:Up |
| 1.3.6.1.4.1.4756.20.150.40.1.19 | Columnf1000EASUtp1NegoLocal | read-write | current | Local device card UTP port 3 negotiation status: 0:Manual 1:Auto |
| 1.3.6.1.4.1.4756.20.150.40.1.20 | Columnf1000EASUtp1SpeedLocal | read-write | current | Local device card UTP port 3 speed setting: 0:10 Base-T 1:100 Base-TX 2:1000 Base-TX |
| 1.3.6.1.4.1.4756.20.150.40.1.21 | Columnf1000EASUtp1DuplexLocal | read-write | current | Local device card UTP port 3 duplex setting: 0:Half duplex mode 1:Full duplex mode |
| 1.3.6.1.4.1.4756.20.150.40.1.22 | Columnf1000EASUtp1SpeedStatusLocal | read-only | current | Local device card UTP port 3 speed status: 0:10 Base-T 1:100 Base-TX 2:1000 Base-TX |
| 1.3.6.1.4.1.4756.20.150.40.1.23 | Columnf1000EASUtp1DuplexStatusLocal | read-only | current | Local device card UTP port 3 duplex status: 0:Half duplex mode 1:Full duplex mode |
| 1.3.6.1.4.1.4756.20.150.40.1.24 | Columnf1000EASUtp2LinkLocal | read-only | current | Local device card UTP port 4 link status: 0:Down 1:Up |
| 1.3.6.1.4.1.4756.20.150.40.1.25 | Columnf1000EASUtp2NegoLocal | read-write | current | Local device card UTP port 4 negotiation status: 0:Manual 1:Auto |
| 1.3.6.1.4.1.4756.20.150.40.1.26 | Columnf1000EASUtp2SpeedLocal | read-write | current | Local device card UTP port 4 speed setting: 0:10 Base-T 1:100 Base-TX 2:1000 Base-TX |
| 1.3.6.1.4.1.4756.20.150.40.1.27 | Columnf1000EASUtp2DuplexLocal | read-write | current | Local device card UTP port 4 duplex setting: 0:Half duplex mode 1:Full duplex mode |
| 1.3.6.1.4.1.4756.20.150.40.1.28 | Columnf1000EASUtp2SpeedStatusLocal | read-only | current | Local device card UTP port 4 speed status: 0:10 Base-T 1:100 Base-TX 2:1000 Base-TX |
| 1.3.6.1.4.1.4756.20.150.40.1.29 | Columnf1000EASUtp2DuplexStatusLocal | read-only | current | Local device card UTP port 4 duplex status: 0:Half duplex mode 1:Full duplex mode |
| 1.3.6.1.4.1.4756.20.150.40.1.30 | Columnf1000EASFx1IrlModeLocal | read-write | current | Local device card port 1 Rate Limit mode: 0:unlimited 1:limited |
| 1.3.6.1.4.1.4756.20.150.40.1.31 | Columnf1000EASFx1IrlIndexLocal | read-write | current | Local device card port 1 Ingress Rate Limit index: Index Limit Rate Index Limit Rate 0 Disable 16 1M 1 250M 17 960K 2 140M 18 896K 3 95M 19 832K 4 57M 20 768K … |
| 1.3.6.1.4.1.4756.20.150.40.1.32 | Columnf1000EASFx1ErlIndexLocal | read-write | current | Local device card port 1 Egress Rate Limit index: Index Limit Rate Index Limit Rate 0 Disable 16 1M 1 250M 17 960K 2 140M 18 896K 3 95M 19 832K 4 57M 20 768K 5… |
| 1.3.6.1.4.1.4756.20.150.40.1.33 | Columnf1000EASFx2IrlModeLocal | read-write | current | Local device card port 2 Rate Limit mode: 0:unlimited 1:limited |
| 1.3.6.1.4.1.4756.20.150.40.1.34 | Columnf1000EASFx2IrlIndexLocal | read-write | current | Local device card port 2 Ingress Rate Limit index: Index Limit Rate Index Limit Rate 0 Disable 16 1M 1 250M 17 960K 2 140M 18 896K 3 95M 19 832K 4 57M 20 768K … |
| 1.3.6.1.4.1.4756.20.150.40.1.35 | Columnf1000EASFx2ErlIndexLocal | read-write | current | Local device card port 2 Egress Rate Limit index: Index Limit Rate Index Limit Rate 0 Disable 16 1M 1 250M 17 960K 2 140M 18 896K 3 95M 19 832K 4 57M 20 768K 5… |
| 1.3.6.1.4.1.4756.20.150.40.1.36 | Columnf1000EASUtp1IrlModeLocal | read-write | current | Local device card port 3 Rate Limit mode: 0:unlimited 1:limited |
| 1.3.6.1.4.1.4756.20.150.40.1.37 | Columnf1000EASUtp1IrlIndexLocal | read-write | current | Local device card port 3 Ingress Rate Limit index: Index Limit Rate Index Limit Rate 0 Disable 16 1M 1 250M 17 960K 2 140M 18 896K 3 95M 19 832K 4 57M 20 768K … |
| 1.3.6.1.4.1.4756.20.150.40.1.38 | Columnf1000EASUtp1ErlIndexLocal | read-write | current | Local device card port 3 Egress Rate Limit index: Index Limit Rate Index Limit Rate 0 Disable 16 1M 1 250M 17 960K 2 140M 18 896K 3 95M 19 832K 4 57M 20 768K 5… |
| 1.3.6.1.4.1.4756.20.150.40.1.39 | Columnf1000EASUtp2IrlModeLocal | read-write | current | Local device card port 4 Rate Limit mode: 0:unlimited 1:limited |
| 1.3.6.1.4.1.4756.20.150.40.1.40 | Columnf1000EASUtp2IrlIndexLocal | read-write | current | Local device card port 4 Ingress Rate Limit index: Index Limit Rate Index Limit Rate 0 Disable 16 1M 1 250M 17 960K 2 140M 18 896K 3 95M 19 832K 4 57M 20 768K … |
| 1.3.6.1.4.1.4756.20.150.40.1.41 | Columnf1000EASUtp2ErlIndexLocal | read-write | current | Local device card port 4 Egress Rate Limit index: Index Limit Rate Index Limit Rate 0 Disable 16 1M 1 250M 17 960K 2 140M 18 896K 3 95M 19 832K 4 57M 20 768K 5… |
| 1.3.6.1.4.1.4756.20.150.40.1.42 | Columnf1000EASDeviceActiveLocal | read-write | current | Local device card active mode: (It is read-only in local device.) 0:Disable 1:Enable |
| 1.3.6.1.4.1.4756.20.150.40.1.43 | Columnf1000EASDeviceResetLocal | read-write | current | Force local device card to reset mode: 0:Off 1:Action |
| 1.3.6.1.4.1.4756.20.150.40.1.44 | Columnf1000EASFx1ActiveLocal | read-write | current | Local device fiber port 1 active mode: 0:Disable 1:Enable |
| 1.3.6.1.4.1.4756.20.150.40.1.45 | Columnf1000EASFx2ActiveLocal | read-write | current | Local device fiber port 2 active mode: 0:Disable 1:Enable |
| 1.3.6.1.4.1.4756.20.150.40.1.46 | Columnf1000EASUtp1ActiveLocal | read-write | current | Local device UTP port 3 active mode: 0:Disable 1:Enable |
| 1.3.6.1.4.1.4756.20.150.40.1.47 | Columnf1000EASUtp2ActiveLocal | read-write | current | Local device UTP port 4 active mode: 0:Disable 1:Enable |
| 1.3.6.1.4.1.4756.20.150.40.1.48 | Columnf1000EASOamChAModeLocal | read-write | current | Local device OAM Channel A mode: 0:Disable 1:passive 2:Active |
| 1.3.6.1.4.1.4756.20.150.40.1.49 | Columnf1000EASOamChBModeLocal | read-write | current | Local device OAM Channel B mode: 0:Disable 1:passive 2:Active |
| 1.3.6.1.4.1.4756.20.150.40.1.50 | Columnf1000EASOamMaxPDUsLocal | read-write | current | Local device OAM max OAMPDU size: 60-1518 Octets |
| 1.3.6.1.4.1.4756.20.150.40.1.51 | Columnf1000EASFx1AlsLocal | read-write | current | Local device card port 1 Auto Laser Shutdown mode: 0:Disable 1:Enable |
| 1.3.6.1.4.1.4756.20.150.40.1.52 | Columnf1000EASFx2AlsLocal | read-write | current | Local device card port 2 Auto Laser Shutdown mode: 0:Disable 1:Enable |
| 1.3.6.1.4.1.4756.20.150.40.1.53 | Columnf1000EASPauseFrameLocal | read-write | current | Local device card pause frame mode: 0:Disable 1:Enable |
| 1.3.6.1.4.1.4756.20.150.40.1.54 | Columnf1000EASSendFHRtoALocal | read-write | current | Local device card port 1 send Fiber Hardware Reset to remote: 0:No action 1:Action |
| 1.3.6.1.4.1.4756.20.150.40.1.55 | Columnf1000EASSendFHRtoBLocal | read-write | current | Local device card port 2 send Fiber Hardware Reset to remote: 0:No action 1:Action |
| 1.3.6.1.4.1.4756.20.150.40.1.56 | Columnf1000EASFx1LLFDepLogiLocal | read-write | current | Local device card port 1 Link Loss Forwarding depends boolean logic: 0:and 1:or |
| 1.3.6.1.4.1.4756.20.150.40.1.57 | Columnf1000EASFx1LLFDepPort2Local | read-write | current | Local device card port 1 Link Loss Forwarding depends on port 2 Fiber Rx link: 0:don't care 1:selected |
| 1.3.6.1.4.1.4756.20.150.40.1.58 | Columnf1000EASFx1LLFDepPort3Local | read-write | current | Local device card port 1 Link Loss Forwarding depends on port 3 Ethernet Rx link: 0:don't care 1:selected |
| 1.3.6.1.4.1.4756.20.150.40.1.59 | Columnf1000EASFx1LLFDepPort4Local | read-write | current | Local device card port 1 Link Loss Forwarding depends on port 4 Ethernet Rx link: 0:don't care 1:selected |
| 1.3.6.1.4.1.4756.20.150.40.1.60 | Columnf1000EASFx2LLFDepLogiLocal | read-write | current | Local device card port 2 Link Loss Forwarding depends boolean logic: 0:and 1:or |
| 1.3.6.1.4.1.4756.20.150.40.1.61 | Columnf1000EASFx2LLFDepPort1Local | read-write | current | Local device card port 2 Link Loss Forwarding depends on port 1 Fiber Rx link: 0:don't care 1:selected |
| 1.3.6.1.4.1.4756.20.150.40.1.62 | Columnf1000EASFx2LLFDepPort3Local | read-write | current | Local device card port 2 Link Loss Forwarding depends on port 3 Ethernet Rx link: 0:don't care 1:selected |
| 1.3.6.1.4.1.4756.20.150.40.1.63 | Columnf1000EASFx2LLFDepPort4Local | read-write | current | Local device card port 2 Link Loss Forwarding depends on port 4 Ethernet Rx link: 0:don't care 1:selected |
| 1.3.6.1.4.1.4756.20.150.40.1.64 | Columnf1000EASUtp1LLFDepLogiLocal | read-write | current | Local device card port 3 Link Loss Forwarding depends boolean logic: 0:and 1:or |
| 1.3.6.1.4.1.4756.20.150.40.1.65 | Columnf1000EASUtp1LLFDepPort1Local | read-write | current | Local device card port 3 Link Loss Forwarding depends on port 1 Fiber Rx link: 0:don't care 1:selected |
| 1.3.6.1.4.1.4756.20.150.40.1.66 | Columnf1000EASUtp1LLFDepPort2Local | read-write | current | Local device card port 3 Link Loss Forwarding depends on port 2 Fiber Rx link: 0:don't care 1:selected |
| 1.3.6.1.4.1.4756.20.150.40.1.67 | Columnf1000EASUtp2LLFDepLogiLocal | read-write | current | Local device card port 4 Link Loss Forwarding depends boolean logic: 0:and 1:or |
| 1.3.6.1.4.1.4756.20.150.40.1.68 | Columnf1000EASUtp2LLFDepPort1Local | read-write | current | Local device card port 4 Link Loss Forwarding depends on port 1 Fiber Rx link: 0:don't care 1:selected |
| 1.3.6.1.4.1.4756.20.150.40.1.69 | Columnf1000EASUtp2LLFDepPort2Local | read-write | current | Local device card port 4 Link Loss Forwarding depends on port 2 Fiber Rx link: 0:don't care 1:selected |
| 1.3.6.1.4.1.4756.20.150.40.1.70 | Columnf1000EASAdvanceFunsLocal | read-write | current | Local device card Switch functions mode: 0:Normal 1:Port 1&2 trunk bandwidth 2G 2:Port 1&2 Mirror 3:Port VLAN 1/3;2/4 4:Port 1&2 Redundancy 5:Static 802.1Q VLA… |
| 1.3.6.1.4.1.4756.20.150.40.1.71 | Columnf1000EASFx1InfoROM1Local | read-only | current | Local device card port 1 INFORemoteOM information 1 valid: 0:Invalid 1:Valid |
| 1.3.6.1.4.1.4756.20.150.40.1.72 | Columnf1000EASFx1InfoROM2Local | read-only | current | Local device card port 1 INFORemoteOM information 2 valid: 0:Invalid 1:Valid(replacing D/D function |
| 1.3.6.1.4.1.4756.20.150.40.1.73 | Columnf1000EASFx2InfoROM1Local | read-only | current | Local device card port 2 INFORemoteOM information 1 valid: 0:Invalid 1:Valid |
| 1.3.6.1.4.1.4756.20.150.40.1.74 | Columnf1000EASFx2InfoROM2Local | read-only | current | Local device card port 2 INFORemoteOM information 2 valid: 0:Invalid 1:Valid(replacing D/D function) |
| 1.3.6.1.4.1.4756.20.150.40.1.75 | Columnf1000EASFx1InfoSN1Local | read-only | current | Local device card port 1 INFORemoteOM S/N 1 |
| 1.3.6.1.4.1.4756.20.150.40.1.76 | Columnf1000EASFx1InfoSN2Local | read-only | current | Local device card port 1 INFORemoteOM S/N 2 |
| 1.3.6.1.4.1.4756.20.150.40.1.77 | Columnf1000EASFx2InfoSN1Local | read-only | current | Local device card port 2 INFORemoteOM S/N 1 |
| 1.3.6.1.4.1.4756.20.150.40.1.78 | Columnf1000EASFx2InfoSN2Local | read-only | current | Local device card port 2 INFORemoteOM S/N 2 |
| 1.3.6.1.4.1.4756.20.150.40.1.79 | Columnf1000EASFx1DDLocal | read-only | current | Local device card fiber port 1 Digital Diagnostic function: 0:No 1:Yes |
| 1.3.6.1.4.1.4756.20.150.40.1.80 | Columnf1000EASFx1DDVendorLocal | read-only | current | Local device card fiber port 1 D/D information: Vendor name |
| 1.3.6.1.4.1.4756.20.150.40.1.81 | Columnf1000EASFx1DDPartNoLocal | read-only | current | Local device card fiber port 1 D/D information: Vendor part number |
| 1.3.6.1.4.1.4756.20.150.40.1.82 | Columnf1000EASFx1DDFiberTypeLocal | read-only | current | Local device card fiber port 1 D/D information: Fiber Type |
| 1.3.6.1.4.1.4756.20.150.40.1.83 | Columnf1000EASFx1DDWaveLenLocal | read-only | current | Local device card fiber port 1 D/D information: Wave length |
| 1.3.6.1.4.1.4756.20.150.40.1.84 | Columnf1000EASFx1DDWaveLen2Local | read-only | current | Local device card fiber port 1 D/D information: Wave length 2 |
| 1.3.6.1.4.1.4756.20.150.40.1.85 | Columnf1000EASFx1DDLinkLenLocal | read-only | current | Local device card fiber port 1 D/D information: Link length |
| 1.3.6.1.4.1.4756.20.150.40.1.86 | Columnf1000EASFx1DDLenUnitLocal | read-only | current | Local device card fiber port 1 D/D information: Length Unit |
| 1.3.6.1.4.1.4756.20.150.40.1.87 | Columnf1000EASFx1DDStatusLocal | read-only | current | Local device card fiber port 1 D/D information: Status Support |
| 1.3.6.1.4.1.4756.20.150.40.1.88 | Columnf1000EASFx1DDRxSensLocal | read-only | current | Local device card fiber port 1 D/D information: Rx Sensitivity |
| 1.3.6.1.4.1.4756.20.150.40.1.89 | Columnf1000EASFx1DDTxPWRLocal | read-only | current | Local device card fiber port 1 D/D information: Tx power |
| 1.3.6.1.4.1.4756.20.150.40.1.90 | Columnf1000EASFx1DDRxPWRLocal | read-only | current | Local device card fiber port 1 D/D information: Rx power |
| 1.3.6.1.4.1.4756.20.150.40.1.91 | Columnf1000EASFx1DDTempLocal | read-only | current | Local device card fiber port 1 D/D information: Temperature in degree C |
| 1.3.6.1.4.1.4756.20.150.40.1.92 | Columnf1000EASFx1DDPWRMarginLocal | read-only | current | Local device card fiber port 1 D/D information: Power margin |
| 1.3.6.1.4.1.4756.20.150.40.1.93 | Columnf1000EASFx1DDPWRLossLocal | read-only | current | Local device card fiber port 1 D/D information: Power loss |
| 1.3.6.1.4.1.4756.20.150.40.1.94 | Columnf1000EASFx2DDLocal | read-only | current | Local device card fiber port 2 Digital Diagnostic function: 0:No 1:Yes |
| 1.3.6.1.4.1.4756.20.150.40.1.95 | Columnf1000EASFx2DDVendorLocal | read-only | current | Local device card fiber port 2 D/D information: Vendor name |
| 1.3.6.1.4.1.4756.20.150.40.1.96 | Columnf1000EASFx2DDPartNoLocal | read-only | current | Local device card fiber port 2 D/D information: Vendor part number |
| 1.3.6.1.4.1.4756.20.150.40.1.97 | Columnf1000EASFx2DDFiberTypeLocal | read-only | current | Local device card fiber port 2 D/D information: Fiber Type |
| 1.3.6.1.4.1.4756.20.150.40.1.98 | Columnf1000EASFx2DDWaveLenLocal | read-only | current | Local device card fiber port 2 D/D information: Wave length |
| 1.3.6.1.4.1.4756.20.150.40.1.99 | Columnf1000EASFx2DDWaveLen2Local | read-only | current | Local device card fiber port 2 D/D information: Wave length 2 |
| 1.3.6.1.4.1.4756.20.150.40.1.100 | Columnf1000EASFx2DDLinkLenLocal | read-only | current | Local device card fiber port 2 D/D information: Link length |
| 1.3.6.1.4.1.4756.20.150.40.1.101 | Columnf1000EASFx2DDLenUnitLocal | read-only | current | Local device card fiber port 2 D/D information: Length Unit |
| 1.3.6.1.4.1.4756.20.150.40.1.102 | Columnf1000EASFx2DDStatusLocal | read-only | current | Local device card fiber port 2 D/D information: Status Support |
| 1.3.6.1.4.1.4756.20.150.40.1.103 | Columnf1000EASFx2DDRxSensLocal | read-only | current | Local device card fiber port 2 D/D information: Rx Sensitivity |
| 1.3.6.1.4.1.4756.20.150.40.1.104 | Columnf1000EASFx2DDTxPWRLocal | read-only | current | Local device card fiber port 2 D/D information: Tx power |
| 1.3.6.1.4.1.4756.20.150.40.1.105 | Columnf1000EASFx2DDRxPWRLocal | read-only | current | Local device card fiber port 2 D/D information: Rx power |
| 1.3.6.1.4.1.4756.20.150.40.1.106 | Columnf1000EASFx2DDTempLocal | read-only | current | Local device card fiber port 2 D/D information: Temperature in degree C |
| 1.3.6.1.4.1.4756.20.150.40.1.107 | Columnf1000EASFx2DDPWRMarginLocal | read-only | current | Local device card fiber port 2 D/D information: Power margin |
| 1.3.6.1.4.1.4756.20.150.40.1.108 | Columnf1000EASFx2DDPWRLossLocal | read-only | current | Local device card fiber port 2 D/D information: Power loss |
| 1.3.6.1.4.1.4756.20.150.40.1.109 | Columnf1000EASClrRMONCntsLocal | read-write | current | Clear local device card RMON IN/OUT counters: 0:No action 1:Action |
| 1.3.6.1.4.1.4756.20.150.40.1.110 | Columnf1000EASFx1RMONInLocal | read-only | current | Local device card port 1 RMON IN counter. |
| 1.3.6.1.4.1.4756.20.150.40.1.111 | Columnf1000EASFx1RMONOutLocal | read-only | current | Local device card port 1 RMON OUT counter. |
| 1.3.6.1.4.1.4756.20.150.40.1.112 | Columnf1000EASFx2RMONInLocal | read-only | current | Local device card port 2 RMON IN counter. |
| 1.3.6.1.4.1.4756.20.150.40.1.113 | Columnf1000EASFx2RMONOutLocal | read-only | current | Local device card port 2 RMON OUT counter. |
| 1.3.6.1.4.1.4756.20.150.40.1.114 | Columnf1000EASUtp1RMONInLocal | read-only | current | Local device card port 3 RMON IN counter. |
| 1.3.6.1.4.1.4756.20.150.40.1.115 | Columnf1000EASUtp1RMONOutLocal | read-only | current | Local device card port 3 RMON OUT counter. |
| 1.3.6.1.4.1.4756.20.150.40.1.116 | Columnf1000EASUtp2RMONInLocal | read-only | current | Local device card port 4 RMON IN counter. |
| 1.3.6.1.4.1.4756.20.150.40.1.117 | Columnf1000EASUtp2RMONOutLocal | read-only | current | Local device card port 4 RMON OUT counter. |
| 1.3.6.1.4.1.4756.20.150.40.1.118 | Columnf1000EASClrOAMCntsLocal | read-write | current | Clear local device card OAM counters: 0:No action 1:Action |
| 1.3.6.1.4.1.4756.20.150.40.1.119 | Columnf1000EASIpModeLocal | read-write | current | On Rack Ip Mode: 0:Enable 1:Disable |
| 1.3.6.1.4.1.4756.20.150.40.1.120 | Columnf1000EASOamChATxLocal | read-only | current | Local device OAM Channel A TX OAMPDU frame count |
| 1.3.6.1.4.1.4756.20.150.40.1.121 | Columnf1000EASOamChARxLocal | read-only | current | Local device OAM Channel A RX OAMPDU frame count |
| 1.3.6.1.4.1.4756.20.150.40.1.122 | Columnf1000EASOamInfoChATxLocal | read-only | current | Local device OAM Channel A TX Information OAMPDU frame count |
| 1.3.6.1.4.1.4756.20.150.40.1.123 | Columnf1000EASOamInfoChARxLocal | read-only | current | Local device OAM Channel A RX Information OAMPDU frame count |
| 1.3.6.1.4.1.4756.20.150.40.1.124 | Columnf1000EASOamEventChATxLocal | read-only | current | Local device OAM Channel A TX Event OAMPDU frame count |
| 1.3.6.1.4.1.4756.20.150.40.1.125 | Columnf1000EASOamUniEvtChARxLocal | read-only | current | Local device OAM Channel A RX Unique Event OAMPDU frame count |
| 1.3.6.1.4.1.4756.20.150.40.1.126 | Columnf1000EASOamDupEvtChARxLocal | read-only | current | Local device OAM Channel A RX Duplicate Event OAMPDU frame count |
| 1.3.6.1.4.1.4756.20.150.40.1.127 | Columnf1000EASOamLbChATxLocal | read-only | current | Local device OAM Channel A TX Loopback Control OAMPDU frame count |
| 1.3.6.1.4.1.4756.20.150.40.1.128 | Columnf1000EASOamLbChARxLocal | read-only | current | Local device OAM Channel A RX Loopback Control OAMPDU frame count |
| 1.3.6.1.4.1.4756.20.150.40.1.129 | Columnf1000EASOamVarReqChATxLocal | read-only | current | Local device OAM Channel A TX Variable Request OAMPDU frame count |
| 1.3.6.1.4.1.4756.20.150.40.1.130 | Columnf1000EASOamVarReqChARxLocal | read-only | current | Local device OAM Channel A RX Variable Request OAMPDU frame count |
| 1.3.6.1.4.1.4756.20.150.40.1.131 | Columnf1000EASOamVarRspChATxLocal | read-only | current | Local device OAM Channel A TX Variable Response OAMPDU frame count |
| 1.3.6.1.4.1.4756.20.150.40.1.132 | Columnf1000EASOamVarRspChARxLocal | read-only | current | Local device OAM Channel A RX Variable Response OAMPDU frame count |
| 1.3.6.1.4.1.4756.20.150.40.1.133 | Columnf1000EASOamOuiChATxLocal | read-only | current | Local device OAM Channel A TX OUI OAMPDU frame count |
| 1.3.6.1.4.1.4756.20.150.40.1.134 | Columnf1000EASOamOuiChARxLocal | read-only | current | Local device OAM Channel A RX OUI OAMPDU frame count |
| 1.3.6.1.4.1.4756.20.150.40.1.135 | Columnf1000EASOamUnknowChARxLocal | read-only | current | Local device OAM Channel A RX Unsupported OAMPDU frame count |
| 1.3.6.1.4.1.4756.20.150.40.1.136 | Columnf1000EASOamChBTxLocal | read-only | current | Local device OAM Channel B TX OAMPDU frame count |
| 1.3.6.1.4.1.4756.20.150.40.1.137 | Columnf1000EASOamChBRxLocal | read-only | current | Local device OAM Channel B RX OAMPDU frame count |
| 1.3.6.1.4.1.4756.20.150.40.1.138 | Columnf1000EASOamInfoChBTxLocal | read-only | current | Local device OAM Channel B TX Information OAMPDU frame count |
| 1.3.6.1.4.1.4756.20.150.40.1.139 | Columnf1000EASOamInfoChBRxLocal | read-only | current | Local device OAM Channel B RX Information OAMPDU frame count |
| 1.3.6.1.4.1.4756.20.150.40.1.140 | Columnf1000EASOamEventChBTxLocal | read-only | current | Local device OAM Channel B TX Event OAMPDU frame count |
| 1.3.6.1.4.1.4756.20.150.40.1.141 | Columnf1000EASOamUniEvtChBRxLocal | read-only | current | Local device OAM Channel B RX Unique Event OAMPDU frame count |
| 1.3.6.1.4.1.4756.20.150.40.1.142 | Columnf1000EASOamDupEvtChBRxLocal | read-only | current | Local device OAM Channel B RX Duplicate Event OAMPDU frame count |
| 1.3.6.1.4.1.4756.20.150.40.1.143 | Columnf1000EASOamLbChBTxLocal | read-only | current | Local device OAM Channel B TX Loopback Control OAMPDU frame count |
| 1.3.6.1.4.1.4756.20.150.40.1.144 | Columnf1000EASOamLbChBRxLocal | read-only | current | Local device OAM Channel B RX Loopback Control OAMPDU frame count |
| 1.3.6.1.4.1.4756.20.150.40.1.145 | Columnf1000EASOamVarReqChBTxLocal | read-only | current | Local device OAM Channel B TX Variable Request OAMPDU frame count |
| 1.3.6.1.4.1.4756.20.150.40.1.146 | Columnf1000EASOamVarReqChBRxLocal | read-only | current | Local device OAM Channel B RX Variable Request OAMPDU frame count |
| 1.3.6.1.4.1.4756.20.150.40.1.147 | Columnf1000EASOamVarRspChBTxLocal | read-only | current | Local device OAM Channel B TX Variable Response OAMPDU frame count |
| 1.3.6.1.4.1.4756.20.150.40.1.148 | Columnf1000EASOamVarRspChBRxLocal | read-only | current | Local device OAM Channel B RX Variable Response OAMPDU frame count |
| 1.3.6.1.4.1.4756.20.150.40.1.149 | Columnf1000EASOamOuiChBTxLocal | read-only | current | Local device OAM Channel B TX OUI OAMPDU frame count |
| 1.3.6.1.4.1.4756.20.150.40.1.150 | Columnf1000EASOamOuiChBRxLocal | read-only | current | Local device OAM Channel B RX OUI OAMPDU frame count |
| 1.3.6.1.4.1.4756.20.150.40.1.151 | Columnf1000EASOamUnknowChBRxLocal | read-only | current | Local device OAM Channel B RX Unsupported OAMPDU frame count |
| 1.3.6.1.4.1.4756.20.150.40.1.152 | Columnf1000EASFx1VLANLocal | read-write | current | Local frm220 f1000EAS Fiber 1 VLAN group : 0:Group A 1:Group B |
| 1.3.6.1.4.1.4756.20.150.40.1.153 | Columnf1000EASFx2VLANLocal | read-write | current | Local frm220 f1000EAS Fiber 2 VLAN group : 0:Group A 1:Group B |
| 1.3.6.1.4.1.4756.20.150.40.1.154 | Columnf1000EASUtp3VLANLocal | read-write | current | Local frm220 f1000EAS UTP 3 VLAN group : 0:Group A 1:Group B |
| 1.3.6.1.4.1.4756.20.150.40.1.155 | Columnf1000EASUtp4VLANLocal | read-write | current | Local frm220 f1000EAS UTP 4 VLAN group : 0:Group A 1:Group B |
| 1.3.6.1.4.1.4756.20.150.40.1.156 | Columnf1000EASManagementLocal | read-write | current | Local frm220 f1000EAS management : 0:Group A 1:Group B 2:Group A+B |
| 1.3.6.1.4.1.4756.20.150.40.1.157 | Columnf1000EASSetDefaultLocal | read-write | current | Local frm220 f1000EAS set to default : 0:OFF 1:Actoin |
| 1.3.6.1.4.1.4756.20.150.40.1.158 | Columnf1000EASPortVLANLocal | read-write | current | Local frm220 Port VLAN : 0:Disable 1:Enable |
| 1.3.6.1.4.1.4756.20.151 | Nodef1000EASRemoteACards | |||
| 1.3.6.1.4.1.4756.20.151.40 | Tablef1000EASRemoteATable | not-accessible | current | A list of local frm220-1000EAS card entries. The number of entries is f1000EASRemoteA. |
| 1.3.6.1.4.1.4756.20.151.40.1 | Rowf1000EASRemoteAEntry | not-accessible | current | An entry containing management information applicable to a particular local frm220-1000EAS card. |
| 1.3.6.1.4.1.4756.20.151.40.1.1 | Columnf1000EASChassisIndexRemoteA | read-only | current | A unique value for each local card. It is the chassis location number. |
| 1.3.6.1.4.1.4756.20.151.40.1.2 | Columnf1000EASSlotIndexRemoteA | read-only | current | A unique value for each local card. It is the slot location number. |
| 1.3.6.1.4.1.4756.20.151.40.1.3 | Columnf1000EASCardHWVerRemoteA | read-only | current | Remote device card hardware version x.xxx |
| 1.3.6.1.4.1.4756.20.151.40.1.4 | Columnf1000EASCardFWVerRemoteA | read-only | current | Remote device card firmware version x.xxx |
| 1.3.6.1.4.1.4756.20.151.40.1.5 | Columnf1000EASCardCPLDVerRemoteA | read-only | current | Remote device card CPLD version x.xxx |
| 1.3.6.1.4.1.4756.20.151.40.1.6 | Columnf1000EASCardFPGAVerRemoteA | read-only | current | Remote device card FPGA version x.xxx |
| 1.3.6.1.4.1.4756.20.151.40.1.7 | Columnf1000EASModelRemoteA | read-only | current | Remote frm220 f1000EAS Serial Type |
| 1.3.6.1.4.1.4756.20.151.40.1.8 | Columnf1000EASFx1LinkRemoteA | read-only | current | Remote device card fiber port 1 link status: 0:Down 1:Up |
| 1.3.6.1.4.1.4756.20.151.40.1.9 | Columnf1000EASFx1OAMLoopedRemoteA | read-only | current | Remote device card fiber port 1 OAM looped: 0:Off 1:on |
| 1.3.6.1.4.1.4756.20.151.40.1.10 | Columnf1000EASFx1LBTestRemoteA | read-write | current | Force remote device card to do fiber port 1 LoopBack testing: 0:Off 1:Action |
| 1.3.6.1.4.1.4756.20.151.40.1.11 | Columnf1000EASFx1OAMRLBStatusRemoteA | read-only | current | Remote device card fiber port 1 LoopBack testing status: 0:Off 1:Ok 2:Fail |
| 1.3.6.1.4.1.4756.20.151.40.1.12 | Columnf1000EASFx1RemoPwrAbRemoteA | read-only | current | Remote device card fiber port 1 Remote Power status: 0:Abnormal 1:OK 2:None |
| 1.3.6.1.4.1.4756.20.151.40.1.13 | Columnf1000EASFx2LinkRemoteA | read-only | current | Remote device card fiber port 2 link status: 0:Down 1:Up |
| 1.3.6.1.4.1.4756.20.151.40.1.14 | Columnf1000EASFx2OAMLoopedRemoteA | read-only | current | Remote device card fiber port 2 OAM looped: 0:Off 1:on |
| 1.3.6.1.4.1.4756.20.151.40.1.15 | Columnf1000EASFx2LBTestRemoteA | read-write | current | Force remote device card to do fiber port 2 LoopBack testing: 0:Off 1:Action |
| 1.3.6.1.4.1.4756.20.151.40.1.16 | Columnf1000EASFx2OAMRLBStatusRemoteA | read-only | current | Remote device card fiber port 1 LoopBack testing status: 0:Off 1:Ok 2:Fail |
| 1.3.6.1.4.1.4756.20.151.40.1.17 | Columnf1000EASFx2RemoPwrAbRemoteA | read-only | current | Remote device card fiber port 2 Remote Power status: 0:Abnormal 1:OK 2:None |
| 1.3.6.1.4.1.4756.20.151.40.1.18 | Columnf1000EASUtp1LinkRemoteA | read-only | current | Remote device card UTP port 3 link status: 0:Down 1:Up |
| 1.3.6.1.4.1.4756.20.151.40.1.19 | Columnf1000EASUtp1NegoRemoteA | read-write | current | Remote device card UTP port 3 negotiation status: 0:Manual 1:Auto |
| 1.3.6.1.4.1.4756.20.151.40.1.20 | Columnf1000EASUtp1SpeedRemoteA | read-write | current | Remote device card UTP port 3 speed setting: 0:10 Base-T 1:100 Base-TX 2:1000 Base-TX |
| 1.3.6.1.4.1.4756.20.151.40.1.21 | Columnf1000EASUtp1DuplexRemoteA | read-write | current | Remote device card UTP port 3 duplex setting: 0:Half duplex mode 1:Full duplex mode |
| 1.3.6.1.4.1.4756.20.151.40.1.22 | Columnf1000EASUtp1SpeedStatusRemoteA | read-only | current | Remote device card UTP port 3 speed status: 0:10 Base-T 1:100 Base-TX 2:1000 Base-TX |
| 1.3.6.1.4.1.4756.20.151.40.1.23 | Columnf1000EASUtp1DuplexStatusRemoteA | read-only | current | Remote device card UTP port 3 duplex status: 0:Half duplex mode 1:Full duplex mode |
| 1.3.6.1.4.1.4756.20.151.40.1.24 | Columnf1000EASUtp2LinkRemoteA | read-only | current | Remote device card UTP port 4 link status: 0:Down 1:Up |
| 1.3.6.1.4.1.4756.20.151.40.1.25 | Columnf1000EASUtp2NegoRemoteA | read-write | current | Remote device card UTP port 4 negotiation status: 0:Manual 1:Auto |
| 1.3.6.1.4.1.4756.20.151.40.1.26 | Columnf1000EASUtp2SpeedRemoteA | read-write | current | Remote device card UTP port 4 speed setting: 0:10 Base-T 1:100 Base-TX 2:1000 Base-TX |
| 1.3.6.1.4.1.4756.20.151.40.1.27 | Columnf1000EASUtp2DuplexRemoteA | read-write | current | Remote device card UTP port 2 duplex setting: 0:Half duplex mode 1:Full duplex mode |
| 1.3.6.1.4.1.4756.20.151.40.1.28 | Columnf1000EASUtp2SpeedStatusRemoteA | read-only | current | Remote device card UTP port 4 speed status: 0:10 Base-T 1:100 Base-TX 2:1000 Base-TX |
| 1.3.6.1.4.1.4756.20.151.40.1.29 | Columnf1000EASUtp2DuplexStatusRemoteA | read-only | current | Remote device card UTP port 2 duplex status: 0:Half duplex mode 1:Full duplex mode |
| 1.3.6.1.4.1.4756.20.151.40.1.30 | Columnf1000EASFx1IrlModeRemoteA | read-write | current | Remote device card port 1 Rate Limit mode: 0:unlimited 1:limited |
| 1.3.6.1.4.1.4756.20.151.40.1.31 | Columnf1000EASFx1IrlIndexRemoteA | read-write | current | Remote device card port 1 Ingress Rate Limit index: Index Limit Rate Index Limit Rate 0 Disable 16 1M 1 250M 17 960K 2 140M 18 896K 3 95M 19 832K 4 57M 20 768K… |
| 1.3.6.1.4.1.4756.20.151.40.1.32 | Columnf1000EASFx1ErlIndexRemoteA | read-write | current | Remote device card port 1 Egress Rate Limit index: Index Limit Rate Index Limit Rate 0 Disable 16 1M 1 250M 17 960K 2 140M 18 896K 3 95M 19 832K 4 57M 20 768K … |
| 1.3.6.1.4.1.4756.20.151.40.1.33 | Columnf1000EASFx2IrlModeRemoteA | read-write | current | Remote device card port 2 Rate Limit mode: 0:unlimited 1:limited |
| 1.3.6.1.4.1.4756.20.151.40.1.34 | Columnf1000EASFx2IrlIndexRemoteA | read-write | current | Remote device card port 2 Ingress Rate Limit index: Index Limit Rate Index Limit Rate 0 Disable 16 1M 1 250M 17 960K 2 140M 18 896K 3 95M 19 832K 4 57M 20 768K… |
| 1.3.6.1.4.1.4756.20.151.40.1.35 | Columnf1000EASFx2ErlIndexRemoteA | read-write | current | Remote device card port 2 Egress Rate Limit index: Index Limit Rate Index Limit Rate 0 Disable 16 1M 1 250M 17 960K 2 140M 18 896K 3 95M 19 832K 4 57M 20 768K … |
| 1.3.6.1.4.1.4756.20.151.40.1.36 | Columnf1000EASUtp1IrlModeRemoteA | read-write | current | Remote device card port 3 Rate Limit mode: 0:unlimited 1:limited |
| 1.3.6.1.4.1.4756.20.151.40.1.37 | Columnf1000EASUtp1IrlIndexRemoteA | read-write | current | Remote device card port 3 Ingress Rate Limit index: Index Limit Rate Index Limit Rate 0 Disable 16 1M 1 250M 17 960K 2 140M 18 896K 3 95M 19 832K 4 57M 20 768K… |
| 1.3.6.1.4.1.4756.20.151.40.1.38 | Columnf1000EASUtp1ErlIndexRemoteA | read-write | current | Remote device card port 3 Egress Rate Limit index: Index Limit Rate Index Limit Rate 0 Disable 16 1M 1 250M 17 960K 2 140M 18 896K 3 95M 19 832K 4 57M 20 768K … |
| 1.3.6.1.4.1.4756.20.151.40.1.39 | Columnf1000EASUtp2IrlModeRemoteA | read-write | current | Remote device card port 4 Rate Limit mode: 0:unlimited 1:limited |
| 1.3.6.1.4.1.4756.20.151.40.1.40 | Columnf1000EASUtp2IrlIndexRemoteA | read-write | current | Remote device card port 4 Ingress Rate Limit index: Index Limit Rate Index Limit Rate 0 Disable 16 1M 1 250M 17 960K 2 140M 18 896K 3 95M 19 832K 4 57M 20 768K… |
| 1.3.6.1.4.1.4756.20.151.40.1.41 | Columnf1000EASUtp2ErlIndexRemoteA | read-write | current | Remote device card port 4 Egress Rate Limit index: Index Limit Rate Index Limit Rate 0 Disable 16 1M 1 250M 17 960K 2 140M 18 896K 3 95M 19 832K 4 57M 20 768K … |
| 1.3.6.1.4.1.4756.20.151.40.1.42 | Columnf1000EASDeviceActiveRemoteA | read-only | current | Remote device card active mode: (It is read-only in local device.) 0:Disable 1:Enable |
| 1.3.6.1.4.1.4756.20.151.40.1.43 | Columnf1000EASDeviceResetRemoteA | read-write | current | Force local device card to reset mode: 0:Off 1:Action |
| 1.3.6.1.4.1.4756.20.151.40.1.44 | Columnf1000EASFx1ActiveRemoteA | read-only | current | Remote device fiber port 1 active mode: 0:Disable 1:Enable |
| 1.3.6.1.4.1.4756.20.151.40.1.45 | Columnf1000EASFx2ActiveRemoteA | read-only | current | Remote device fiber port 2 active mode: 0:Disable 1:Enable |
| 1.3.6.1.4.1.4756.20.151.40.1.46 | Columnf1000EASUtp1ActiveRemoteA | read-write | current | Remote device UTP port 3 active mode: 0:Disable 1:Enable |
| 1.3.6.1.4.1.4756.20.151.40.1.47 | Columnf1000EASUtp2ActiveRemoteA | read-write | current | Remote device UTP port 4 active mode: 0:Disable 1:Enable |
| 1.3.6.1.4.1.4756.20.151.40.1.48 | Columnf1000EASOAMChAModeRemoteA | read-write | current | Remote device OAM Channel A mode: 0:Passive 1:Active |
| 1.3.6.1.4.1.4756.20.151.40.1.49 | Columnf1000EASOAMChBModeRemoteA | read-write | current | Remote device OAM Channel B mode: 0:Passive 1:Active |
| 1.3.6.1.4.1.4756.20.151.40.1.50 | Columnf1000EASOamMaxPDUsRemoteA | read-write | current | Remote device OAM max OAMPDU size: 60-1518 Octets |
| 1.3.6.1.4.1.4756.20.151.40.1.51 | Columnf1000EASFx1AlsRemoteA | read-write | current | Remote device card port 1 Auto Laser Shutdown mode: 0:Disable 1:Enable |
| 1.3.6.1.4.1.4756.20.151.40.1.52 | Columnf1000EASFx2AlsRemoteA | read-write | current | Remote device card port 2 Auto Laser Shutdown mode: 0:Disable 1:Enable |
| 1.3.6.1.4.1.4756.20.151.40.1.53 | Columnf1000EASPauseFrameRemoteA | read-write | current | Remote device card pause frame mode: 0:Disable 1:Enable |
| 1.3.6.1.4.1.4756.20.151.40.1.54 | Columnf1000EASFhrModeRemoteA | read-write | current | Remote device card accepts remote Fiber Hardware Reset mode: 0:Disable 1:Enable |
| 1.3.6.1.4.1.4756.20.151.40.1.55 | Columnf1000EASFx1LLFDepLogiRemoteA | read-write | current | Remote device card port 1 Link Loss Forwarding depends boolean logic: 0:and 1:or |
| 1.3.6.1.4.1.4756.20.151.40.1.56 | Columnf1000EASFx1LLFDepPort2RemoteA | read-write | current | Remote device card port 1 Link Loss Forwarding depends on port 2 Fiber Rx link: 0:don't care 1:selected |
| 1.3.6.1.4.1.4756.20.151.40.1.57 | Columnf1000EASFx1LLFDepPort3RemoteA | read-write | current | Remote device card port 1 Link Loss Forwarding depends on port 3 Ethernet Rx link: 0:don't care 1:selected |
| 1.3.6.1.4.1.4756.20.151.40.1.58 | Columnf1000EASFx1LLFDepPort4RemoteA | read-write | current | Remote device card port 1 Link Loss Forwarding depends on port 4 Ethernet Rx link: 0:don't care 1:selected |
| 1.3.6.1.4.1.4756.20.151.40.1.59 | Columnf1000EASFx2LLFDepLogiRemoteA | read-write | current | Remote device card port 2 Link Loss Forwarding depends boolean logic: 0:and 1:or |
| 1.3.6.1.4.1.4756.20.151.40.1.60 | Columnf1000EASFx2LLFDepPort1RemoteA | read-write | current | Remote device card port 2 Link Loss Forwarding depends on port 1 Fiber Rx link: 0:don't care 1:selected |
| 1.3.6.1.4.1.4756.20.151.40.1.61 | Columnf1000EASFx2LLFDepPort3RemoteA | read-write | current | Remote device card port 2 Link Loss Forwarding depends on port 3 Ethernet Rx link: 0:don't care 1:selected |
| 1.3.6.1.4.1.4756.20.151.40.1.62 | Columnf1000EASFx2LLFDepPort4RemoteA | read-write | current | Remote device card port 2 Link Loss Forwarding depends on port 4 Ethernet Rx link: 0:don't care 1:selected |
| 1.3.6.1.4.1.4756.20.151.40.1.63 | Columnf1000EASUtp1LLFDepLogiRemoteA | read-write | current | Remote device card port 3 Link Loss Forwarding depends boolean logic: 0:and 1:or |
| 1.3.6.1.4.1.4756.20.151.40.1.64 | Columnf1000EASUtp1LLFDepPort1RemoteA | read-write | current | Remote device card port 3 Link Loss Forwarding depends on port 1 Fiber Rx link: 0:don't care 1:selected |
| 1.3.6.1.4.1.4756.20.151.40.1.65 | Columnf1000EASUtp1LLFDepPort2RemoteA | read-write | current | Remote device card port 3 Link Loss Forwarding depends on port 2 Fiber Rx link: 0:don't care 1:selected |
| 1.3.6.1.4.1.4756.20.151.40.1.66 | Columnf1000EASUtp2LLFDepLogiRemoteA | read-write | current | Remote device card port 4 Link Loss Forwarding depends boolean logic: 0:and 1:or |
| 1.3.6.1.4.1.4756.20.151.40.1.67 | Columnf1000EASUtp2LLFDepPort1RemoteA | read-write | current | Remote device card port 4 Link Loss Forwarding depends on port 1 Fiber Rx link: 0:don't care 1:selected |
| 1.3.6.1.4.1.4756.20.151.40.1.68 | Columnf1000EASUtp2LLFDepPort2RemoteA | read-write | current | Remote device card port 4 Link Loss Forwarding depends on port 2 Fiber Rx link: 0:don't care 1:selected |
| 1.3.6.1.4.1.4756.20.151.40.1.69 | Columnf1000EASAdvanceFunsRemoteA | read-write | current | Remote device card Switch functions mode: 0:Normal 1:Port 1&2 trunk bandwidth 2G 2:Port 1&2 Mirror 3:Port VLAN 1/3;2/4 4:Port 1&2 Redundancy 5:Static 802.1Q VL… |
| 1.3.6.1.4.1.4756.20.151.40.1.70 | Columnf1000EASFx1InfoROM1RemoteA | read-only | current | Remote device card port 1 INFORemoteOM information 1 valid: 0:Invalid 1:Valid |
| 1.3.6.1.4.1.4756.20.151.40.1.71 | Columnf1000EASFx1InfoROM2RemoteA | read-only | current | Remote device card port 1 INFORemoteOM information 2 valid: 0:Invalid 1:Valid(replacing D/D function |
| 1.3.6.1.4.1.4756.20.151.40.1.72 | Columnf1000EASFx2InfoROM1RemoteA | read-only | current | Remote device card port 2 INFORemoteOM information 1 valid: 0:Invalid 1:Valid |
| 1.3.6.1.4.1.4756.20.151.40.1.73 | Columnf1000EASFx2InfoROM2RemoteA | read-only | current | Remote device card port 2 INFORemoteOM information 2 valid: 0:Invalid 1:Valid(replacing D/D function) |
| 1.3.6.1.4.1.4756.20.151.40.1.74 | Columnf1000EASFx1InfoSN1RemoteA | read-only | current | Remote device card port 1 INFORemoteOM S/N 1 |
| 1.3.6.1.4.1.4756.20.151.40.1.75 | Columnf1000EASFx1InfoSN2RemoteA | read-only | current | Remote device card port 1 INFORemoteOM S/N 2 |
| 1.3.6.1.4.1.4756.20.151.40.1.76 | Columnf1000EASFx2InfoSN1RemoteA | read-only | current | Remote device card port 2 INFORemoteOM S/N 1 |
| 1.3.6.1.4.1.4756.20.151.40.1.77 | Columnf1000EASFx2InfoSN2RemoteA | read-only | current | Remote device card port 2 INFORemoteOM S/N 2 |
| 1.3.6.1.4.1.4756.20.151.40.1.78 | Columnf1000EASFx1DDRemoteA | read-only | current | Remote device card fiber port 1 Digital Diagnostic function: 0:No 1:Yes |
| 1.3.6.1.4.1.4756.20.151.40.1.79 | Columnf1000EASFx1DDVendorRemoteA | read-only | current | Remote device card fiber port 1 D/D information: Vendor name |
| 1.3.6.1.4.1.4756.20.151.40.1.80 | Columnf1000EASFx1DDPartNoRemoteA | read-only | current | Remote device card fiber port 1 D/D information: Vendor part number |
| 1.3.6.1.4.1.4756.20.151.40.1.81 | Columnf1000EASFx1DDFiberTypeRemoteA | read-only | current | Remote device card fiber port 1 D/D information: Fiber Type |
| 1.3.6.1.4.1.4756.20.151.40.1.82 | Columnf1000EASFx1DDWaveLenRemoteA | read-only | current | Remote device card fiber port 1 D/D information: Wave length |
| 1.3.6.1.4.1.4756.20.151.40.1.83 | Columnf1000EASFx1DDWaveLen2RemoteA | read-only | current | Remote device card fiber port 1 D/D information: Wave length 2 |
| 1.3.6.1.4.1.4756.20.151.40.1.84 | Columnf1000EASFx1DDLinkLenRemoteA | read-only | current | Remote device card fiber port 1 D/D information: Link length |
| 1.3.6.1.4.1.4756.20.151.40.1.85 | Columnf1000EASFx1DDLenUnitRemoteA | read-only | current | Remote device card fiber port 1 D/D information: Length Unit |
| 1.3.6.1.4.1.4756.20.151.40.1.86 | Columnf1000EASFx1DDStatusRemoteA | read-only | current | Remote device card fiber port 1 D/D information: Status Support |
| 1.3.6.1.4.1.4756.20.151.40.1.87 | Columnf1000EASFx1DDRxSensRemoteA | read-only | current | Remote device card fiber port 1 D/D information: Rx Sensitivity |
| 1.3.6.1.4.1.4756.20.151.40.1.88 | Columnf1000EASFx1DDTxPWRRemoteA | read-only | current | Remote device card fiber port 1 D/D information: Tx power |
| 1.3.6.1.4.1.4756.20.151.40.1.89 | Columnf1000EASFx1DDRxPWRRemoteA | read-only | current | Remote device card fiber port 1 D/D information: Rx power |
| 1.3.6.1.4.1.4756.20.151.40.1.90 | Columnf1000EASFx1DDTempRemoteA | read-only | current | Remote device card fiber port 1 D/D information: Temperature in degree C |
| 1.3.6.1.4.1.4756.20.151.40.1.91 | Columnf1000EASFx1DDPWRMarginRemoteA | read-only | current | Remote device card fiber port 1 D/D information: Power margin |
| 1.3.6.1.4.1.4756.20.151.40.1.92 | Columnf1000EASFx1DDPWRLossRemoteA | read-only | current | Remote device card fiber port 1 D/D information: Power loss |
| 1.3.6.1.4.1.4756.20.151.40.1.93 | Columnf1000EASFx2DDRemoteA | read-only | current | Remote device card fiber port 2 Digital Diagnostic function: 0:No 1:Yes |
| 1.3.6.1.4.1.4756.20.151.40.1.94 | Columnf1000EASFx2DDVendorRemoteA | read-only | current | Remote device card fiber port 2 D/D information: Vendor name |
| 1.3.6.1.4.1.4756.20.151.40.1.95 | Columnf1000EASFx2DDPartNoRemoteA | read-only | current | Remote device card fiber port 2 D/D information: Vendor part number |
| 1.3.6.1.4.1.4756.20.151.40.1.96 | Columnf1000EASFx2DDFiberTypeRemoteA | read-only | current | Remote device card fiber port 2 D/D information: Fiber Type |
| 1.3.6.1.4.1.4756.20.151.40.1.97 | Columnf1000EASFx2DDWaveLenRemoteA | read-only | current | Remote device card fiber port 2 D/D information: Wave length |
| 1.3.6.1.4.1.4756.20.151.40.1.98 | Columnf1000EASFx2DDWaveLen2RemoteA | read-only | current | Remote device card fiber port 2 D/D information: Wave length 2 |
| 1.3.6.1.4.1.4756.20.151.40.1.99 | Columnf1000EASFx2DDLinkLenRemoteA | read-only | current | Remote device card fiber port 2 D/D information: Link length |
| 1.3.6.1.4.1.4756.20.151.40.1.100 | Columnf1000EASFx2DDLenUnitRemoteA | read-only | current | Remote device card fiber port 2 D/D information: Length Unit |
| 1.3.6.1.4.1.4756.20.151.40.1.101 | Columnf1000EASFx2DDStatusRemoteA | read-only | current | Remote device card fiber port 2 D/D information: Status Support |
| 1.3.6.1.4.1.4756.20.151.40.1.102 | Columnf1000EASFx2DDRxSensRemoteA | read-only | current | Remote device card fiber port 2 D/D information: Rx Sensitivity |
| 1.3.6.1.4.1.4756.20.151.40.1.103 | Columnf1000EASFx2DDTxPWRRemoteA | read-only | current | Remote device card fiber port 2 D/D information: Tx power |
| 1.3.6.1.4.1.4756.20.151.40.1.104 | Columnf1000EASFx2DDRxPWRRemoteA | read-only | current | Remote device card fiber port 2 D/D information: Rx power |
| 1.3.6.1.4.1.4756.20.151.40.1.105 | Columnf1000EASFx2DDTempRemoteA | read-only | current | Remote device card fiber port 2 D/D information: Temperature in degree C |
| 1.3.6.1.4.1.4756.20.151.40.1.106 | Columnf1000EASFx2DDPWRMarginRemoteA | read-only | current | Remote device card fiber port 2 D/D information: Power margin |
| 1.3.6.1.4.1.4756.20.151.40.1.107 | Columnf1000EASFx2DDPWRLossRemoteA | read-only | current | Remote device card fiber port 2 D/D information: Power loss |
| 1.3.6.1.4.1.4756.20.151.40.1.108 | Columnf1000EASClrRMONCntsRemoteA | read-write | current | Clear local device card RMON IN/OUT counters: 0:No action 1:Action |
| 1.3.6.1.4.1.4756.20.151.40.1.109 | Columnf1000EASFx1RMONInRemoteA | read-only | current | Remote device card port 1 RMON IN counter. |
| 1.3.6.1.4.1.4756.20.151.40.1.110 | Columnf1000EASFx1RMONOutRemoteA | read-only | current | Remote device card port 1 RMON OUT counter. |
| 1.3.6.1.4.1.4756.20.151.40.1.111 | Columnf1000EASFx2RMONInRemoteA | read-only | current | Remote device card port 2 RMON IN counter. |
| 1.3.6.1.4.1.4756.20.151.40.1.112 | Columnf1000EASFx2RMONOutRemoteA | read-only | current | Remote device card port 2 RMON OUT counter. |
| 1.3.6.1.4.1.4756.20.151.40.1.113 | Columnf1000EASUtp1RMONInRemoteA | read-only | current | Remote device card port 3 RMON IN counter. |
| 1.3.6.1.4.1.4756.20.151.40.1.114 | Columnf1000EASUtp1RMONOutRemoteA | read-only | current | Remote device card port 3 RMON OUT counter. |
| 1.3.6.1.4.1.4756.20.151.40.1.115 | Columnf1000EASUtp2RMONInRemoteA | read-only | current | Remote device card port 4 RMON IN counter. |
| 1.3.6.1.4.1.4756.20.151.40.1.116 | Columnf1000EASUtp2RMONOutRemoteA | read-only | current | Remote device card port 4 RMON OUT counter. |
| 1.3.6.1.4.1.4756.20.151.40.1.117 | Columnf1000EASClrOAMCntsRemoteA | read-write | current | Clear local device card OAM counters: 0:No action 1:Action |
| 1.3.6.1.4.1.4756.20.151.40.1.118 | Columnf1000EASIpModeRemoteA | read-write | current | On Rack Ip Mode: 0:Enable 1:Disable |
| 1.3.6.1.4.1.4756.20.151.40.1.119 | Columnf1000EASOamChATxRemoteA | read-only | current | Remote device OAM Channel A TX OAMPDU frame count |
| 1.3.6.1.4.1.4756.20.151.40.1.120 | Columnf1000EASOamChARxRemoteA | read-only | current | Remote device OAM Channel A RX OAMPDU frame count |
| 1.3.6.1.4.1.4756.20.151.40.1.121 | Columnf1000EASOamInfoChATxRemoteA | read-only | current | Remote device OAM Channel A TX Information OAMPDU frame count |
| 1.3.6.1.4.1.4756.20.151.40.1.122 | Columnf1000EASOamInfoChARxRemoteA | read-only | current | Remote device OAM Channel A RX Information OAMPDU frame count |
| 1.3.6.1.4.1.4756.20.151.40.1.123 | Columnf1000EASOamEventChATxRemoteA | read-only | current | Remote device OAM Channel A TX Event OAMPDU frame count |
| 1.3.6.1.4.1.4756.20.151.40.1.124 | Columnf1000EASOamUniEvtChARxRemoteA | read-only | current | Remote device OAM Channel A RX Unique Event OAMPDU frame count |
| 1.3.6.1.4.1.4756.20.151.40.1.125 | Columnf1000EASOamDupEvtChARxRemoteA | read-only | current | Remote device OAM Channel A RX Duplicate Event OAMPDU frame count |
| 1.3.6.1.4.1.4756.20.151.40.1.126 | Columnf1000EASOamLbChATxRemoteA | read-only | current | Remote device OAM Channel A TX Loopback Control OAMPDU frame count |
| 1.3.6.1.4.1.4756.20.151.40.1.127 | Columnf1000EASOamLbChARxRemoteA | read-only | current | Remote device OAM Channel A RX Loopback Control OAMPDU frame count |
| 1.3.6.1.4.1.4756.20.151.40.1.128 | Columnf1000EASOamVarReqChATxRemoteA | read-only | current | Remote device OAM Channel A TX Variable Request OAMPDU frame count |
| 1.3.6.1.4.1.4756.20.151.40.1.129 | Columnf1000EASOamVarReqChARxRemoteA | read-only | current | Remote device OAM Channel A RX Variable Request OAMPDU frame count |
| 1.3.6.1.4.1.4756.20.151.40.1.130 | Columnf1000EASOamVarRspChATxRemoteA | read-only | current | Remote device OAM Channel A TX Variable Response OAMPDU frame count |
| 1.3.6.1.4.1.4756.20.151.40.1.131 | Columnf1000EASOamVarRspChARxRemoteA | read-only | current | Remote device OAM Channel A RX Variable Response OAMPDU frame count |
| 1.3.6.1.4.1.4756.20.151.40.1.132 | Columnf1000EASOamOuiChATxRemoteA | read-only | current | Remote device OAM Channel A TX OUI OAMPDU frame count |
| 1.3.6.1.4.1.4756.20.151.40.1.133 | Columnf1000EASOamOuiChARxRemoteA | read-only | current | Remote device OAM Channel A RX OUI OAMPDU frame count |
| 1.3.6.1.4.1.4756.20.151.40.1.134 | Columnf1000EASOamUnknowChARxRemoteA | read-only | current | Remote device OAM Channel A RX Unsupported OAMPDU frame count |
| 1.3.6.1.4.1.4756.20.151.40.1.135 | Columnf1000EASOamChBTxRemoteA | read-only | current | Remote device OAM Channel B TX OAMPDU frame count |
| 1.3.6.1.4.1.4756.20.151.40.1.136 | Columnf1000EASOamChBRxRemoteA | read-only | current | Remote device OAM Channel B RX OAMPDU frame count |
| 1.3.6.1.4.1.4756.20.151.40.1.137 | Columnf1000EASOamInfoChBTxRemoteA | read-only | current | Remote device OAM Channel B TX Information OAMPDU frame count |
| 1.3.6.1.4.1.4756.20.151.40.1.138 | Columnf1000EASOamInfoChBRxRemoteA | read-only | current | Remote device OAM Channel B RX Information OAMPDU frame count |
| 1.3.6.1.4.1.4756.20.151.40.1.139 | Columnf1000EASOamEventChBTxRemoteA | read-only | current | Remote device OAM Channel B TX Event OAMPDU frame count |
| 1.3.6.1.4.1.4756.20.151.40.1.140 | Columnf1000EASOamUniEvtChBRxRemoteA | read-only | current | Remote device OAM Channel B RX Unique Event OAMPDU frame count |
| 1.3.6.1.4.1.4756.20.151.40.1.141 | Columnf1000EASOamDupEvtChBRxRemoteA | read-only | current | Remote device OAM Channel B RX Duplicate Event OAMPDU frame count |
| 1.3.6.1.4.1.4756.20.151.40.1.142 | Columnf1000EASOamLbChBTxRemoteA | read-only | current | Remote device OAM Channel B TX Loopback Control OAMPDU frame count |
| 1.3.6.1.4.1.4756.20.151.40.1.143 | Columnf1000EASOamLbChBRxRemoteA | read-only | current | Remote device OAM Channel B RX Loopback Control OAMPDU frame count |
| 1.3.6.1.4.1.4756.20.151.40.1.144 | Columnf1000EASOamVarReqChBTxRemoteA | read-only | current | Remote device OAM Channel B TX Variable Request OAMPDU frame count |
| 1.3.6.1.4.1.4756.20.151.40.1.145 | Columnf1000EASOamVarReqChBRxRemoteA | read-only | current | Remote device OAM Channel B RX Variable Request OAMPDU frame count |
| 1.3.6.1.4.1.4756.20.151.40.1.146 | Columnf1000EASOamVarRspChBTxRemoteA | read-only | current | Remote device OAM Channel B TX Variable Response OAMPDU frame count |
| 1.3.6.1.4.1.4756.20.151.40.1.147 | Columnf1000EASOamVarRspChBRxRemoteA | read-only | current | Remote device OAM Channel B RX Variable Response OAMPDU frame count |
| 1.3.6.1.4.1.4756.20.151.40.1.148 | Columnf1000EASOamOuiChBTxRemoteA | read-only | current | Remote device OAM Channel B TX OUI OAMPDU frame count |
| 1.3.6.1.4.1.4756.20.151.40.1.149 | Columnf1000EASOamOuiChBRxRemoteA | read-only | current | Remote device OAM Channel B RX OUI OAMPDU frame count |
| 1.3.6.1.4.1.4756.20.151.40.1.150 | Columnf1000EASOamUnknowChBRxRemoteA | read-only | current | Remote device OAM Channel B RX Unsupported OAMPDU frame count |
| 1.3.6.1.4.1.4756.20.151.40.1.151 | Columnf1000EASFx1VLANRemoteA | read-write | current | RemoteA frm220 f1000EAS Fiber 1 VLAN group : 0:Group A 1:Group B |
| 1.3.6.1.4.1.4756.20.151.40.1.152 | Columnf1000EASFx2VLANRemoteA | read-write | current | RemoteA frm220 f1000EAS Fiber 2 VLAN group : 0:Group A 1:Group B |
| 1.3.6.1.4.1.4756.20.151.40.1.153 | Columnf1000EASUtp3VLANRemoteA | read-write | current | RemoteA frm220 f1000EAS UTP 3 VLAN group : 0:Group A 1:Group B |
| 1.3.6.1.4.1.4756.20.151.40.1.154 | Columnf1000EASUtp4VLANRemoteA | read-write | current | RemoteA frm220 f1000EAS UTP 4 VLAN group : 0:Group A 1:Group B |
| 1.3.6.1.4.1.4756.20.151.40.1.155 | Columnf1000EASManagementRemoteA | read-write | current | RemoteA frm220 f1000EAS management : 0:Group A 1:Group B 2:Group A+B |
| 1.3.6.1.4.1.4756.20.151.40.1.156 | Columnf1000EASSetDefaultRemoteA | read-write | current | RemoteA frm220 f1000EAS set to default : 0:OFF 1:Actoin |
| 1.3.6.1.4.1.4756.20.151.40.1.157 | Columnf1000EASPortVLANRemoteA | read-write | current | RemoteA frm220 Port VLAN : 0:Disable 1:Enable |
| 1.3.6.1.4.1.4756.20.152 | Nodef1000EASRemoteBCards | |||
| 1.3.6.1.4.1.4756.20.152.40 | Tablef1000EASRemoteBTable | not-accessible | current | A list of local frm220-1000EAS card entries. The number of entries is f1000EAS-NoRemoteB. |
| 1.3.6.1.4.1.4756.20.152.40.1 | Rowf1000EASRemoteBEntry | not-accessible | current | An entry containing management information applicable to a particular local frm220-1000EAS card. |
| 1.3.6.1.4.1.4756.20.152.40.1.1 | Columnf1000EASChassisIndexRemoteB | read-only | current | A unique value for each local card. It is the chassis location number. |
| 1.3.6.1.4.1.4756.20.152.40.1.2 | Columnf1000EASSlotIndexRemoteB | read-only | current | A unique value for each local card. It is the slot location number. |
| 1.3.6.1.4.1.4756.20.152.40.1.3 | Columnf1000EASCardHWVerRemoteB | read-only | current | Remote device card hardware version x.xxx |
| 1.3.6.1.4.1.4756.20.152.40.1.4 | Columnf1000EASCardFWVerRemoteB | read-only | current | Remote device card firmware version x.xxx |
| 1.3.6.1.4.1.4756.20.152.40.1.5 | Columnf1000EASCardCPLDVerRemoteB | read-only | current | Remote device card CPLD version x.xxx |
| 1.3.6.1.4.1.4756.20.152.40.1.6 | Columnf1000EASCardFPGAVerRemoteB | read-only | current | Remote device card FPGA version x.xxx |
| 1.3.6.1.4.1.4756.20.152.40.1.7 | Columnf1000EASModelRemoteB | read-only | current | Remote frm220 f1000EAS Serial Type |
| 1.3.6.1.4.1.4756.20.152.40.1.8 | Columnf1000EASFx1LinkRemoteB | read-only | current | Remote device card fiber port 1 link status: 0:Down 1:Up |
| 1.3.6.1.4.1.4756.20.152.40.1.9 | Columnf1000EASFx1OAMLoopedRemoteB | read-only | current | Remote device card fiber port 1 OAM looped: 0:Off 1:on |
| 1.3.6.1.4.1.4756.20.152.40.1.10 | Columnf1000EASFx1LBTestRemoteB | read-write | current | Force remote device card to do fiber port 1 LoopBack testing: 0:Off 1:Action |
| 1.3.6.1.4.1.4756.20.152.40.1.11 | Columnf1000EASFx1OAMRLBStatusRemoteB | read-only | current | Remote device card fiber port 1 LoopBack testing status: 0:Off 1:Ok 2:Fail |
| 1.3.6.1.4.1.4756.20.152.40.1.12 | Columnf1000EASFx1RemoPwrAbRemoteB | read-only | current | Remote device card fiber port 1 Remote Power status: 0:Abnormal 1:OK 2:None |
| 1.3.6.1.4.1.4756.20.152.40.1.13 | Columnf1000EASFx2LinkRemoteB | read-only | current | Remote device card fiber port 2 link status: 0:Down 1:Up |
| 1.3.6.1.4.1.4756.20.152.40.1.14 | Columnf1000EASFx2OAMLoopedRemoteB | read-only | current | Remote device card fiber port 2 OAM looped: 0:Off 1:on |
| 1.3.6.1.4.1.4756.20.152.40.1.15 | Columnf1000EASFx2LBTestRemoteB | read-write | current | Force remote device card to do fiber port 2 LoopBack testing: 0:Off 1:Action |
| 1.3.6.1.4.1.4756.20.152.40.1.16 | Columnf1000EASFx2OAMRLBStatusRemoteB | read-only | current | Remote device card fiber port 2 LoopBack testing status: 0:Off 1:Ok 2:Fail |
| 1.3.6.1.4.1.4756.20.152.40.1.17 | Columnf1000EASFx2RemoPwrAbRemoteB | read-only | current | Remote device card fiber port 2 Remote Power status: 0:Abnormal 1:OK 2:None |
| 1.3.6.1.4.1.4756.20.152.40.1.18 | Columnf1000EASUtp1LinkRemoteB | read-only | current | Remote device card UTP port 3 link status: 0:Down 1:Up |
| 1.3.6.1.4.1.4756.20.152.40.1.19 | Columnf1000EASUtp1NegoRemoteB | read-write | current | Remote device card UTP port 3 negotiation status: 0:Manual 1:Auto |
| 1.3.6.1.4.1.4756.20.152.40.1.20 | Columnf1000EASUtp1SpeedRemoteB | read-write | current | Remote device card UTP port 3 speed setting: 0:10 Base-T 1:100 Base-TX 2:1000 Base-TX |
| 1.3.6.1.4.1.4756.20.152.40.1.21 | Columnf1000EASUtp1DuplexRemoteB | read-write | current | Remote device card UTP port 3 duplex setting: 0:Half duplex mode 1:Full duplex mode |
| 1.3.6.1.4.1.4756.20.152.40.1.22 | Columnf1000EASUtp1SpeedStatusRemoteB | read-only | current | Remote device card UTP port 3 speed status: 0:10 Base-T 1:100 Base-TX 2:1000 Base-TX |
| 1.3.6.1.4.1.4756.20.152.40.1.23 | Columnf1000EASUtp1DuplexStatusRemoteB | read-only | current | Remote device card UTP port 3 duplex status: 0:Half duplex mode 1:Full duplex mode |
| 1.3.6.1.4.1.4756.20.152.40.1.24 | Columnf1000EASUtp2LinkRemoteB | read-only | current | Remote device card UTP port 4 link status: 0:Down 1:Up |
| 1.3.6.1.4.1.4756.20.152.40.1.25 | Columnf1000EASUtp2NegoRemoteB | read-write | current | Remote device card UTP port 4 negotiation status: 0:Manual 1:Auto |
| 1.3.6.1.4.1.4756.20.152.40.1.26 | Columnf1000EASUtp2SpeedRemoteB | read-write | current | Remote device card UTP port 4 speed setting: 0:10 Base-T 1:100 Base-TX 2:1000 Base-TX |
| 1.3.6.1.4.1.4756.20.152.40.1.27 | Columnf1000EASUtp2DuplexRemoteB | read-write | current | Remote device card UTP port 4 duplex setting: 0:Half duplex mode 1:Full duplex mode |
| 1.3.6.1.4.1.4756.20.152.40.1.28 | Columnf1000EASUtp2SpeedStatusRemoteB | read-only | current | Remote device card UTP port 4 speed status: 0:10 Base-T 1:100 Base-TX 2:1000 Base-TX |
| 1.3.6.1.4.1.4756.20.152.40.1.29 | Columnf1000EASUtp2DuplexStatusRemoteB | read-only | current | Remote device card UTP port 4 duplex status: 0:Half duplex mode 1:Full duplex mode |
| 1.3.6.1.4.1.4756.20.152.40.1.30 | Columnf1000EASFx1IrlModeRemoteB | read-write | current | Remote device card port 1 Rate Limit mode: 0:unlimited 1:limited |
| 1.3.6.1.4.1.4756.20.152.40.1.31 | Columnf1000EASFx1IrlIndexRemoteB | read-write | current | Remote device card port 1 Ingress Rate Limit index: Index Limit Rate Index Limit Rate 0 Disable 16 1M 1 250M 17 960K 2 140M 18 896K 3 95M 19 832K 4 57M 20 768K… |
| 1.3.6.1.4.1.4756.20.152.40.1.32 | Columnf1000EASFx1ErlIndexRemoteB | read-write | current | Remote device card port 1 Egress Rate Limit index: Index Limit Rate Index Limit Rate 0 Disable 16 1M 1 250M 17 960K 2 140M 18 896K 3 95M 19 832K 4 57M 20 768K … |
| 1.3.6.1.4.1.4756.20.152.40.1.33 | Columnf1000EASFx2IrlModeRemoteB | read-write | current | Remote device card port 2 Rate Limit mode: 0:unlimited 1:limited |
| 1.3.6.1.4.1.4756.20.152.40.1.34 | Columnf1000EASFx2IrlIndexRemoteB | read-write | current | Remote device card port 2 Ingress Rate Limit index: Index Limit Rate Index Limit Rate 0 Disable 16 1M 1 250M 17 960K 2 140M 18 896K 3 95M 19 832K 4 57M 20 768K… |
| 1.3.6.1.4.1.4756.20.152.40.1.35 | Columnf1000EASFx2ErlIndexRemoteB | read-write | current | Remote device card port 2 Egress Rate Limit index: Index Limit Rate Index Limit Rate 0 Disable 16 1M 1 250M 17 960K 2 140M 18 896K 3 95M 19 832K 4 57M 20 768K … |
| 1.3.6.1.4.1.4756.20.152.40.1.36 | Columnf1000EASUtp1IrlModeRemoteB | read-write | current | Remote device card port 3 Rate Limit mode: 0:unlimited 1:limited |
| 1.3.6.1.4.1.4756.20.152.40.1.37 | Columnf1000EASUtp1IrlIndexRemoteB | read-write | current | Remote device card port 3 Ingress Rate Limit index: Index Limit Rate Index Limit Rate 0 Disable 16 1M 1 250M 17 960K 2 140M 18 896K 3 95M 19 832K 4 57M 20 768K… |
| 1.3.6.1.4.1.4756.20.152.40.1.38 | Columnf1000EASUtp1ErlIndexRemoteB | read-write | current | Remote device card port 3 Egress Rate Limit index: Index Limit Rate Index Limit Rate 0 Disable 16 1M 1 250M 17 960K 2 140M 18 896K 3 95M 19 832K 4 57M 20 768K … |
| 1.3.6.1.4.1.4756.20.152.40.1.39 | Columnf1000EASUtp2IrlModeRemoteB | read-write | current | Remote device card port 4 Rate Limit mode: 0:unlimited 1:limited |
| 1.3.6.1.4.1.4756.20.152.40.1.40 | Columnf1000EASUtp2IrlIndexRemoteB | read-write | current | Remote device card port 4 Ingress Rate Limit index: Index Limit Rate Index Limit Rate 0 Disable 16 1M 1 250M 17 960K 2 140M 18 896K 3 95M 19 832K 4 57M 20 768K… |
| 1.3.6.1.4.1.4756.20.152.40.1.41 | Columnf1000EASUtp2ErlIndexRemoteB | read-write | current | Remote device card port 4 Egress Rate Limit index: Index Limit Rate Index Limit Rate 0 Disable 16 1M 1 250M 17 960K 2 140M 18 896K 3 95M 19 832K 4 57M 20 768K … |
| 1.3.6.1.4.1.4756.20.152.40.1.42 | Columnf1000EASDeviceActiveRemoteB | read-only | current | Remote device card active mode: (It is read-only in local device.) 0:Disable 1:Enable |
| 1.3.6.1.4.1.4756.20.152.40.1.43 | Columnf1000EASDeviceResetRemoteB | read-write | current | Force local device card to reset mode: 0:Off 1:Action |
| 1.3.6.1.4.1.4756.20.152.40.1.44 | Columnf1000EASFx1ActiveRemoteB | read-only | current | Remote device fiber port 1 active mode: 0:Disable 1:Enable |
| 1.3.6.1.4.1.4756.20.152.40.1.45 | Columnf1000EASFx2ActiveRemoteB | read-only | current | Remote device fiber port 2 active mode: 0:Disable 1:Enable |
| 1.3.6.1.4.1.4756.20.152.40.1.46 | Columnf1000EASUtp1ActiveRemoteB | read-write | current | Remote device UTP port 3 active mode: 0:Disable 1:Enable |
| 1.3.6.1.4.1.4756.20.152.40.1.47 | Columnf1000EASUtp2ActiveRemoteB | read-write | current | Remote device UTP port 4 active mode: 0:Disable 1:Enable |
| 1.3.6.1.4.1.4756.20.152.40.1.48 | Columnf1000EASOAMChAModeRemoteB | read-write | current | Remote device OAM Channel A mode: 0:Passive 1:Active |
| 1.3.6.1.4.1.4756.20.152.40.1.49 | Columnf1000EASOAMChBModeRemoteB | read-write | current | Remote device OAM Channel B mode: 0:Passive 1:Active |
| 1.3.6.1.4.1.4756.20.152.40.1.50 | Columnf1000EASOamMaxPDUsRemoteB | read-write | current | Remote device OAM max OAMPDU size: 60-1518 Octets |
| 1.3.6.1.4.1.4756.20.152.40.1.51 | Columnf1000EASFx1AlsRemoteB | read-write | current | Remote device card port 1 Auto Laser Shutdown mode: 0:Disable 1:Enable |
| 1.3.6.1.4.1.4756.20.152.40.1.52 | Columnf1000EASFx2AlsRemoteB | read-write | current | Remote device card port 2 Auto Laser Shutdown mode: 0:Disable 1:Enable |
| 1.3.6.1.4.1.4756.20.152.40.1.53 | Columnf1000EASPauseFrameRemoteB | read-write | current | Remote device card pause frame mode: 0:Disable 1:Enable |
| 1.3.6.1.4.1.4756.20.152.40.1.54 | Columnf1000EASFhrModeRemoteB | read-write | current | Remote device card accepts remote Fiber Hardware Reset mode: 0:Disable 1:Enable |
| 1.3.6.1.4.1.4756.20.152.40.1.55 | Columnf1000EASFx1LLFDepLogiRemoteB | read-write | current | Remote device card port 1 Link Loss Forwarding depends boolean logic: 0:and 1:or |
| 1.3.6.1.4.1.4756.20.152.40.1.56 | Columnf1000EASFx1LLFDepPort2RemoteB | read-write | current | Remote device card port 1 Link Loss Forwarding depends on port 2 Fiber Rx link: 0:don't care 1:selected |
| 1.3.6.1.4.1.4756.20.152.40.1.57 | Columnf1000EASFx1LLFDepPort3RemoteB | read-write | current | Remote device card port 1 Link Loss Forwarding depends on port 3 Ethernet Rx link: 0:don't care 1:selected |
| 1.3.6.1.4.1.4756.20.152.40.1.58 | Columnf1000EASFx1LLFDepPort4RemoteB | read-write | current | Remote device card port 1 Link Loss Forwarding depends on port 4 Ethernet Rx link: 0:don't care 1:selected |
| 1.3.6.1.4.1.4756.20.152.40.1.59 | Columnf1000EASFx2LLFDepLogiRemoteB | read-write | current | Remote device card port 2 Link Loss Forwarding depends boolean logic: 0:and 1:or |
| 1.3.6.1.4.1.4756.20.152.40.1.60 | Columnf1000EASFx2LLFDepPort1RemoteB | read-write | current | Remote device card port 2 Link Loss Forwarding depends on port 1 Fiber Rx link: 0:don't care 1:selected |
| 1.3.6.1.4.1.4756.20.152.40.1.61 | Columnf1000EASFx2LLFDepPort3RemoteB | read-write | current | Remote device card port 2 Link Loss Forwarding depends on port 3 Ethernet Rx link: 0:don't care 1:selected |
| 1.3.6.1.4.1.4756.20.152.40.1.62 | Columnf1000EASFx2LLFDepPort4RemoteB | read-write | current | Remote device card port 2 Link Loss Forwarding depends on port 4 Ethernet Rx link: 0:don't care 1:selected |
| 1.3.6.1.4.1.4756.20.152.40.1.63 | Columnf1000EASUtp1LLFDepLogiRemoteB | read-write | current | Remote device card port 3 Link Loss Forwarding depends boolean logic: 0:and 1:or |
| 1.3.6.1.4.1.4756.20.152.40.1.64 | Columnf1000EASUtp1LLFDepPort1RemoteB | read-write | current | Remote device card port 3 Link Loss Forwarding depends on port 1 Fiber Rx link: 0:don't care 1:selected |
| 1.3.6.1.4.1.4756.20.152.40.1.65 | Columnf1000EASUtp1LLFDepPort2RemoteB | read-write | current | Remote device card port 3 Link Loss Forwarding depends on port 2 Fiber Rx link: 0:don't care 1:selected |
| 1.3.6.1.4.1.4756.20.152.40.1.66 | Columnf1000EASUtp2LLFDepLogiRemoteB | read-write | current | Remote device card port 4 Link Loss Forwarding depends boolean logic: 0:and 1:or |
| 1.3.6.1.4.1.4756.20.152.40.1.67 | Columnf1000EASUtp2LLFDepPort1RemoteB | read-write | current | Remote device card port 4 Link Loss Forwarding depends on port 1 Fiber Rx link: 0:don't care 1:selected |
| 1.3.6.1.4.1.4756.20.152.40.1.68 | Columnf1000EASUtp2LLFDepPort2RemoteB | read-write | current | Remote device card port 4 Link Loss Forwarding depends on port 2 Fiber Rx link: 0:don't care 1:selected |
| 1.3.6.1.4.1.4756.20.152.40.1.69 | Columnf1000EASAdvanceFunsRemoteB | read-write | current | Remote device card Switch functions mode: 0:Normal 1:Port 1&2 trunk bandwidth 2G 2:Port 1&2 Mirror 3:Port VLAN 1/3;2/4 4:Port 1&2 Redundancy 5:Static 802.1Q VL… |
| 1.3.6.1.4.1.4756.20.152.40.1.70 | Columnf1000EASFx1InfoROM1RemoteB | read-only | current | Remote device card port 1 INFORemoteOM information 1 valid: 0:Invalid 1:Valid |
| 1.3.6.1.4.1.4756.20.152.40.1.71 | Columnf1000EASFx1InfoROM2RemoteB | read-only | current | Remote device card port 1 INFORemoteOM information 2 valid: 0:Invalid 1:Valid(replacing D/D function |
| 1.3.6.1.4.1.4756.20.152.40.1.72 | Columnf1000EASFx2InfoROM1RemoteB | read-only | current | Remote device card port 2 INFORemoteOM information 1 valid: 0:Invalid 1:Valid |
| 1.3.6.1.4.1.4756.20.152.40.1.73 | Columnf1000EASFx2InfoROM2RemoteB | read-only | current | Remote device card port 2 INFORemoteOM information 2 valid: 0:Invalid 1:Valid(replacing D/D function) |
| 1.3.6.1.4.1.4756.20.152.40.1.74 | Columnf1000EASFx1InfoSN1RemoteB | read-only | current | Remote device card port 1 INFORemoteOM S/N 1 |
| 1.3.6.1.4.1.4756.20.152.40.1.75 | Columnf1000EASFx1InfoSN2RemoteB | read-only | current | Remote device card port 1 INFORemoteOM S/N 2 |
| 1.3.6.1.4.1.4756.20.152.40.1.76 | Columnf1000EASFx2InfoSN1RemoteB | read-only | current | Remote device card port 2 INFORemoteOM S/N 1 |
| 1.3.6.1.4.1.4756.20.152.40.1.77 | Columnf1000EASFx2InfoSN2RemoteB | read-only | current | Remote device card port 2 INFORemoteOM S/N 2 |
| 1.3.6.1.4.1.4756.20.152.40.1.78 | Columnf1000EASFx1DDRemoteB | read-only | current | Remote device card fiber port 1 Digital Diagnostic function: 0:No 1:Yes |
| 1.3.6.1.4.1.4756.20.152.40.1.79 | Columnf1000EASFx1DDVendorRemoteB | read-only | current | Remote device card fiber port 1 D/D information: Vendor name |
| 1.3.6.1.4.1.4756.20.152.40.1.80 | Columnf1000EASFx1DDPartNoRemoteB | read-only | current | Remote device card fiber port 1 D/D information: Vendor part number |
| 1.3.6.1.4.1.4756.20.152.40.1.81 | Columnf1000EASFx1DDFiberTypeRemoteB | read-only | current | Remote device card fiber port 1 D/D information: Fiber Type |
| 1.3.6.1.4.1.4756.20.152.40.1.82 | Columnf1000EASFx1DDWaveLenRemoteB | read-only | current | Remote device card fiber port 1 D/D information: Wave length |
| 1.3.6.1.4.1.4756.20.152.40.1.83 | Columnf1000EASFx1DDWaveLen2RemoteB | read-only | current | Remote device card fiber port 1 D/D information: Wave length 2 |
| 1.3.6.1.4.1.4756.20.152.40.1.84 | Columnf1000EASFx1DDLinkLenRemoteB | read-only | current | Remote device card fiber port 1 D/D information: Link length |
| 1.3.6.1.4.1.4756.20.152.40.1.85 | Columnf1000EASFx1DDLenUnitRemoteB | read-only | current | Remote device card fiber port 1 D/D information: Length Unit |
| 1.3.6.1.4.1.4756.20.152.40.1.86 | Columnf1000EASFx1DDStatusRemoteB | read-only | current | Remote device card fiber port 1 D/D information: Status Support |
| 1.3.6.1.4.1.4756.20.152.40.1.87 | Columnf1000EASFx1DDRxSensRemoteB | read-only | current | Remote device card fiber port 1 D/D information: Rx Sensitivity |
| 1.3.6.1.4.1.4756.20.152.40.1.88 | Columnf1000EASFx1DDTxPWRRemoteB | read-only | current | Remote device card fiber port 1 D/D information: Tx power |
| 1.3.6.1.4.1.4756.20.152.40.1.89 | Columnf1000EASFx1DDRxPWRRemoteB | read-only | current | Remote device card fiber port 1 D/D information: Rx power |
| 1.3.6.1.4.1.4756.20.152.40.1.90 | Columnf1000EASFx1DDTempRemoteB | read-only | current | Remote device card fiber port 1 D/D information: Temperature in degree C |
| 1.3.6.1.4.1.4756.20.152.40.1.91 | Columnf1000EASFx1DDPWRMarginRemoteB | read-only | current | Remote device card fiber port 1 D/D information: Power margin |
| 1.3.6.1.4.1.4756.20.152.40.1.92 | Columnf1000EASFx1DDPWRLossRemoteB | read-only | current | Remote device card fiber port 1 D/D information: Power loss |
| 1.3.6.1.4.1.4756.20.152.40.1.93 | Columnf1000EASFx2DDRemoteB | read-only | current | Remote device card fiber port 2 Digital Diagnostic function: 0:No 1:Yes |
| 1.3.6.1.4.1.4756.20.152.40.1.94 | Columnf1000EASFx2DDVendorRemoteB | read-only | current | Remote device card fiber port 2 D/D information: Vendor name |
| 1.3.6.1.4.1.4756.20.152.40.1.95 | Columnf1000EASFx2DDPartNoRemoteB | read-only | current | Remote device card fiber port 2 D/D information: Vendor part number |
| 1.3.6.1.4.1.4756.20.152.40.1.96 | Columnf1000EASFx2DDFiberTypeRemoteB | read-only | current | Remote device card fiber port 2 D/D information: Fiber Type |
| 1.3.6.1.4.1.4756.20.152.40.1.97 | Columnf1000EASFx2DDWaveLenRemoteB | read-only | current | Remote device card fiber port 2 D/D information: Wave length |
| 1.3.6.1.4.1.4756.20.152.40.1.98 | Columnf1000EASFx2DDWaveLen2RemoteB | read-only | current | Remote device card fiber port 2 D/D information: Wave length 2 |
| 1.3.6.1.4.1.4756.20.152.40.1.99 | Columnf1000EASFx2DDLinkLenRemoteB | read-only | current | Remote device card fiber port 2 D/D information: Link length |
| 1.3.6.1.4.1.4756.20.152.40.1.100 | Columnf1000EASFx2DDLenUnitRemoteB | read-only | current | Remote device card fiber port 2 D/D information: Length Unit |
| 1.3.6.1.4.1.4756.20.152.40.1.101 | Columnf1000EASFx2DDStatusRemoteB | read-only | current | Remote device card fiber port 2 D/D information: Status Support |
| 1.3.6.1.4.1.4756.20.152.40.1.102 | Columnf1000EASFx2DDRxSensRemoteB | read-only | current | Remote device card fiber port 2 D/D information: Rx Sensitivity |
| 1.3.6.1.4.1.4756.20.152.40.1.103 | Columnf1000EASFx2DDTxPWRRemoteB | read-only | current | Remote device card fiber port 2 D/D information: Tx power |
| 1.3.6.1.4.1.4756.20.152.40.1.104 | Columnf1000EASFx2DDRxPWRRemoteB | read-only | current | Remote device card fiber port 2 D/D information: Rx power |
| 1.3.6.1.4.1.4756.20.152.40.1.105 | Columnf1000EASFx2DDTempRemoteB | read-only | current | Remote device card fiber port 2 D/D information: Temperature in degree C |
| 1.3.6.1.4.1.4756.20.152.40.1.106 | Columnf1000EASFx2DDPWRMarginRemoteB | read-only | current | Remote device card fiber port 2 D/D information: Power margin |
| 1.3.6.1.4.1.4756.20.152.40.1.107 | Columnf1000EASFx2DDPWRLossRemoteB | read-only | current | Remote device card fiber port 2 D/D information: Power loss |
| 1.3.6.1.4.1.4756.20.152.40.1.108 | Columnf1000EASClrRMONCntsRemoteB | read-write | current | Clear local device card RMON IN/OUT counters: 0:No action 1:Action |
| 1.3.6.1.4.1.4756.20.152.40.1.109 | Columnf1000EASFx1RMONInRemoteB | read-only | current | Remote device card port 1 RMON IN counter. |
| 1.3.6.1.4.1.4756.20.152.40.1.110 | Columnf1000EASFx1RMONOutRemoteB | read-only | current | Remote device card port 1 RMON OUT counter. |
| 1.3.6.1.4.1.4756.20.152.40.1.111 | Columnf1000EASFx2RMONInRemoteB | read-only | current | Remote device card port 2 RMON IN counter. |
| 1.3.6.1.4.1.4756.20.152.40.1.112 | Columnf1000EASFx2RMONOutRemoteB | read-only | current | Remote device card port 2 RMON OUT counter. |
| 1.3.6.1.4.1.4756.20.152.40.1.113 | Columnf1000EASUtp1RMONInRemoteB | read-only | current | Remote device card port 3 RMON IN counter. |
| 1.3.6.1.4.1.4756.20.152.40.1.114 | Columnf1000EASUtp1RMONOutRemoteB | read-only | current | Remote device card port 3 RMON OUT counter. |
| 1.3.6.1.4.1.4756.20.152.40.1.115 | Columnf1000EASUtp2RMONInRemoteB | read-only | current | Remote device card port 4 RMON IN counter. |
| 1.3.6.1.4.1.4756.20.152.40.1.116 | Columnf1000EASUtp2RMONOutRemoteB | read-only | current | Remote device card port 4 RMON OUT counter. |
| 1.3.6.1.4.1.4756.20.152.40.1.117 | Columnf1000EASClrOAMCntsRemoteB | read-write | current | Clear local device card OAM counters: 0:No action 1:Action |
| 1.3.6.1.4.1.4756.20.152.40.1.118 | Columnf1000EASIpModeRemoteB | read-write | current | On Rack Ip Mode: 0:Enable 1:Disable |
| 1.3.6.1.4.1.4756.20.152.40.1.119 | Columnf1000EASOamChATxRemoteB | read-only | current | Remote device OAM Channel A TX OAMPDU frame count |
| 1.3.6.1.4.1.4756.20.152.40.1.120 | Columnf1000EASOamChARxRemoteB | read-only | current | Remote device OAM Channel A RX OAMPDU frame count |
| 1.3.6.1.4.1.4756.20.152.40.1.121 | Columnf1000EASOamInfoChATxRemoteB | read-only | current | Remote device OAM Channel A TX Information OAMPDU frame count |
| 1.3.6.1.4.1.4756.20.152.40.1.122 | Columnf1000EASOamInfoChARxRemoteB | read-only | current | Remote device OAM Channel A RX Information OAMPDU frame count |
| 1.3.6.1.4.1.4756.20.152.40.1.123 | Columnf1000EASOamEventChATxRemoteB | read-only | current | Remote device OAM Channel A TX Event OAMPDU frame count |
| 1.3.6.1.4.1.4756.20.152.40.1.124 | Columnf1000EASOamUniEvtChARxRemoteB | read-only | current | Remote device OAM Channel A RX Unique Event OAMPDU frame count |
| 1.3.6.1.4.1.4756.20.152.40.1.125 | Columnf1000EASOamDupEvtChARxRemoteB | read-only | current | Remote device OAM Channel A RX Duplicate Event OAMPDU frame count |
| 1.3.6.1.4.1.4756.20.152.40.1.126 | Columnf1000EASOamLbChATxRemoteB | read-only | current | Remote device OAM Channel A TX Loopback Control OAMPDU frame count |
| 1.3.6.1.4.1.4756.20.152.40.1.127 | Columnf1000EASOamLbChARxRemoteB | read-only | current | Remote device OAM Channel A RX Loopback Control OAMPDU frame count |
| 1.3.6.1.4.1.4756.20.152.40.1.128 | Columnf1000EASOamVarReqChATxRemoteB | read-only | current | Remote device OAM Channel A TX Variable Request OAMPDU frame count |
| 1.3.6.1.4.1.4756.20.152.40.1.129 | Columnf1000EASOamVarReqChARxRemoteB | read-only | current | Remote device OAM Channel A RX Variable Request OAMPDU frame count |
| 1.3.6.1.4.1.4756.20.152.40.1.130 | Columnf1000EASOamVarRspChATxRemoteB | read-only | current | Remote device OAM Channel A TX Variable Response OAMPDU frame count |
| 1.3.6.1.4.1.4756.20.152.40.1.131 | Columnf1000EASOamVarRspChARxRemoteB | read-only | current | Remote device OAM Channel A RX Variable Response OAMPDU frame count |
| 1.3.6.1.4.1.4756.20.152.40.1.132 | Columnf1000EASOamOuiChATxRemoteB | read-only | current | Remote device OAM Channel A TX OUI OAMPDU frame count |
| 1.3.6.1.4.1.4756.20.152.40.1.133 | Columnf1000EASOamOuiChARxRemoteB | read-only | current | Remote device OAM Channel A RX OUI OAMPDU frame count |
| 1.3.6.1.4.1.4756.20.152.40.1.134 | Columnf1000EASOamUnknowChARxRemoteB | read-only | current | Remote device OAM Channel A RX Unsupported OAMPDU frame count |
| 1.3.6.1.4.1.4756.20.152.40.1.135 | Columnf1000EASOamChBTxRemoteB | read-only | current | Remote device OAM Channel B TX OAMPDU frame count |
| 1.3.6.1.4.1.4756.20.152.40.1.136 | Columnf1000EASOamChBRxRemoteB | read-only | current | Remote device OAM Channel B RX OAMPDU frame count |
| 1.3.6.1.4.1.4756.20.152.40.1.137 | Columnf1000EASOamInfoChBTxRemoteB | read-only | current | Remote device OAM Channel B TX Information OAMPDU frame count |
| 1.3.6.1.4.1.4756.20.152.40.1.138 | Columnf1000EASOamInfoChBRxRemoteB | read-only | current | Remote device OAM Channel B RX Information OAMPDU frame count |
| 1.3.6.1.4.1.4756.20.152.40.1.139 | Columnf1000EASOamEventChBTxRemoteB | read-only | current | Remote device OAM Channel B TX Event OAMPDU frame count |
| 1.3.6.1.4.1.4756.20.152.40.1.140 | Columnf1000EASOamUniEvtChBRxRemoteB | read-only | current | Remote device OAM Channel B RX Unique Event OAMPDU frame count |
| 1.3.6.1.4.1.4756.20.152.40.1.141 | Columnf1000EASOamDupEvtChBRxRemoteB | read-only | current | Remote device OAM Channel B RX Duplicate Event OAMPDU frame count |
| 1.3.6.1.4.1.4756.20.152.40.1.142 | Columnf1000EASOamLbChBTxRemoteB | read-only | current | Remote device OAM Channel B TX Loopback Control OAMPDU frame count |
| 1.3.6.1.4.1.4756.20.152.40.1.143 | Columnf1000EASOamLbChBRxRemoteB | read-only | current | Remote device OAM Channel B RX Loopback Control OAMPDU frame count |
| 1.3.6.1.4.1.4756.20.152.40.1.144 | Columnf1000EASOamVarReqChBTxRemoteB | read-only | current | Remote device OAM Channel B TX Variable Request OAMPDU frame count |
| 1.3.6.1.4.1.4756.20.152.40.1.145 | Columnf1000EASOamVarReqChBRxRemoteB | read-only | current | Remote device OAM Channel B RX Variable Request OAMPDU frame count |
| 1.3.6.1.4.1.4756.20.152.40.1.146 | Columnf1000EASOamVarRspChBTxRemoteB | read-only | current | Remote device OAM Channel B TX Variable Response OAMPDU frame count |
| 1.3.6.1.4.1.4756.20.152.40.1.147 | Columnf1000EASOamVarRspChBRxRemoteB | read-only | current | Remote device OAM Channel B RX Variable Response OAMPDU frame count |
| 1.3.6.1.4.1.4756.20.152.40.1.148 | Columnf1000EASOamOuiChBTxRemoteB | read-only | current | Remote device OAM Channel B TX OUI OAMPDU frame count |
| 1.3.6.1.4.1.4756.20.152.40.1.149 | Columnf1000EASOamOuiChBRxRemoteB | read-only | current | Remote device OAM Channel B RX OUI OAMPDU frame count |
| 1.3.6.1.4.1.4756.20.152.40.1.150 | Columnf1000EASOamUnknowChBRxRemoteB | read-only | current | Remote device OAM Channel B RX Unsupported OAMPDU frame count |
| 1.3.6.1.4.1.4756.20.152.40.1.151 | Columnf1000EASFx1VLANRemoteB | read-write | current | RemoteB frm220 f1000EAS Fiber 1 VLAN group : 0:Group A 1:Group B |
| 1.3.6.1.4.1.4756.20.152.40.1.152 | Columnf1000EASFx2VLANRemoteB | read-write | current | RemoteB frm220 f1000EAS Fiber 2 VLAN group : 0:Group A 1:Group B |
| 1.3.6.1.4.1.4756.20.152.40.1.153 | Columnf1000EASUtp3VLANRemoteB | read-write | current | RemoteB frm220 f1000EAS UTP 3 VLAN group : 0:Group A 1:Group B |
| 1.3.6.1.4.1.4756.20.152.40.1.154 | Columnf1000EASUtp4VLANRemoteB | read-write | current | RemoteB frm220 f1000EAS UTP 4 VLAN group : 0:Group A 1:Group B |
| 1.3.6.1.4.1.4756.20.152.40.1.155 | Columnf1000EASManagementRemoteB | read-write | current | RemoteB frm220 f1000EAS management : 0:Group A 1:Group B 2:Group A+B |
| 1.3.6.1.4.1.4756.20.152.40.1.156 | Columnf1000EASSetDefaultRemoteB | read-write | current | RemoteB frm220 f1000EAS set to default : 0:OFF 1:Actoin |
| 1.3.6.1.4.1.4756.20.152.40.1.157 | Columnf1000EASPortVLANRemoteB | read-write | current | RemoteB frm220 Port VLAN : 0:Disable 1:Enable |
| 1.3.6.1.4.1.4756.20.160 | NodefE1LocalCards | |||
| 1.3.6.1.4.1.4756.20.160.20 | TablefE1LocalTable | not-accessible | current | A list of local FRM220-E1-ET100 series card entries. The number of entries is fE1-No-L. |
| 1.3.6.1.4.1.4756.20.160.20.1 | RowfE1LocalEntry | not-accessible | current | An entry containing management information applicable to a particular local FRM220- series card. |
| 1.3.6.1.4.1.4756.20.160.20.1.1 | ColumnfE1ChassisIndexLocal | read-only | current | A unique value for each local card. It is the chassis location number. |
| 1.3.6.1.4.1.4756.20.160.20.1.2 | ColumnfE1SlotIndexLocal | read-only | current | A unique value for each local card. It is the slot location number. |
| 1.3.6.1.4.1.4756.20.160.20.1.3 | ColumnfE1CardHWVerLocal | read-only | current | Local FRM220-E1/ET100 Series card hardware version x.xxx |
| 1.3.6.1.4.1.4756.20.160.20.1.4 | ColumnfE1CardFWVerLocal | read-only | current | Local FRM220-E1/ET100 Series card firmware version x.xxx |
| 1.3.6.1.4.1.4756.20.160.20.1.5 | ColumnfE1CardCPLDVerLocal | read-only | current | Local FRM220-E1/ET100 Series card CPLD version x.xxx |
| 1.3.6.1.4.1.4756.20.160.20.1.6 | ColumnfE1CardFPGAVerLocal | read-only | current | Local FRM220-E1/ET100 Series card FPGA version x.xxx |
| 1.3.6.1.4.1.4756.20.160.20.1.7 | ColumnfE1PortActiveLocal | read-write | current | Local FRM220-E1/ET100 Series card active: 0:Disable 1:Enable |
| 1.3.6.1.4.1.4756.20.160.20.1.8 | ColumnfE1PortResetLocal | read-write | current | Local FRM220-E1/ET100 Series card portreset: 0:OFF 1:Action |
| 1.3.6.1.4.1.4756.20.160.20.1.9 | ColumnfE1SettoDefaultLocal | read-write | current | Local FRM220-E1/ET100 Series card set to default: 0:OFF 1:Action |
| 1.3.6.1.4.1.4756.20.160.20.1.10 | ColumnfE1SignalLocal | read-only | current | Local FRM220-E1/ET100 Series card E1 signal status: 0:Signal Loss 1:Normal |
| 1.3.6.1.4.1.4756.20.160.20.1.11 | ColumnfE1SyncLocal | read-only | current | Local FRM220-E1/ET100 Series card E1 sync status: 0:Sync Loss 1:Normal |
| 1.3.6.1.4.1.4756.20.160.20.1.12 | ColumnfE1RdSTSLocal | read-only | current | Local FRM220-E1/ET100 Series card RD status: 0:ON 1:OFF 2:Flash |
| 1.3.6.1.4.1.4756.20.160.20.1.13 | ColumnfE1TdSTSLocal | read-only | current | Local FRM220-E1/ET100 Series card TD status: 0:ON 1:OFF 2:Flash |
| 1.3.6.1.4.1.4756.20.160.20.1.14 | ColumnfE1ReAisLocal | read-only | current | Local FRM220-E1/ET100 Series card E1 receive AIS: 0:NO 1:Have |
| 1.3.6.1.4.1.4756.20.160.20.1.15 | ColumnfE1LOMFLocal | read-only | current | Local FRM220-E1/ET100 Series card E1 loss of multiframe sync: 0:NO 1:Have |
| 1.3.6.1.4.1.4756.20.160.20.1.16 | ColumnfE1LinecodeViolationLocal | read-only | current | Local FRM220-E1/ET100 Series card E1 line code violation: 0:NO 1:Have |
| 1.3.6.1.4.1.4756.20.160.20.1.17 | ColumnfE1BertErrLocal | read-only | current | Local FRM220-E1/ET100 Series card E1 bert error: 0:NO 1:Have |
| 1.3.6.1.4.1.4756.20.160.20.1.18 | ColumnfE1RemoPwAbLocal | read-only | current | Local FRM220-E1/ET100 Series card remote power fail: 0:OK 1:Failue |
| 1.3.6.1.4.1.4756.20.160.20.1.19 | ColumnfE1Utp1LinkLocal | read-only | current | Local FRM220-E1/ET100 Series card utp link status: 0:Down 1:Lind up |
| 1.3.6.1.4.1.4756.20.160.20.1.20 | ColumnfE1Utp1SpeedSTSLocal | read-only | current | Local FRM220-E1/ET100 Series card utp1 speed status : 0:10M 1:100M |
| 1.3.6.1.4.1.4756.20.160.20.1.21 | ColumnfE1Utp1DuplexSTSLocal | read-only | current | Local FRM220-E1/ET100 Series card utp1 duplex status : 0:Half 1:Full |
| 1.3.6.1.4.1.4756.20.160.20.1.22 | ColumnfE1Utp1NegLocal | read-write | current | Local FRM220-E1/ET100 Series card utp1 negotiation : 0:Manual 1:Auto |
| 1.3.6.1.4.1.4756.20.160.20.1.23 | ColumnfE1Utp1SpeedLocal | read-write | current | Local FRM220-E1/ET100 Series card utp1 speed: 0:10M 1:100M |
| 1.3.6.1.4.1.4756.20.160.20.1.24 | ColumnfE1Utp1DuplexLocal | read-write | current | Local FRM220-E1/ET100 Series card utp1 duplex: 0:Half 1:Full |
| 1.3.6.1.4.1.4756.20.160.20.1.25 | ColumnfE1Utp1FlowCrlLocal | read-write | current | Local FRM220-E1/ET100 Series card utp1 flow control: 0:Disable 1:Enable |
| 1.3.6.1.4.1.4756.20.160.20.1.26 | ColumnfE1FrameLocal | read-write | current | Local FRM220-E1/ET100 Series card E1 frame: 0:Unframed 1:Framed |
| 1.3.6.1.4.1.4756.20.160.20.1.27 | ColumnfE1TimeSlot1Local | read-write | current | Local FRM220-E1/ET100 Series card timeslot1: 0:Inactive 1:Active |
| 1.3.6.1.4.1.4756.20.160.20.1.28 | ColumnfE1TimeSlot2Local | read-write | current | Local FRM220-E1/ET100 Series card timeslot2: 0:Inactive 1:Active |
| 1.3.6.1.4.1.4756.20.160.20.1.29 | ColumnfE1TimeSlot3Local | read-write | current | Local FRM220-E1/ET100 Series card timeslot3: 0:Inactive 1:Active |
| 1.3.6.1.4.1.4756.20.160.20.1.30 | ColumnfE1TimeSlot4Local | read-write | current | Local FRM220-E1/ET100 Series card timeslot4: 0:Inactive 1:Active |
| 1.3.6.1.4.1.4756.20.160.20.1.31 | ColumnfE1TimeSlot5Local | read-write | current | Local FRM220-E1/ET100 Series card timeslot5: 0:Inactive 1:Active |
| 1.3.6.1.4.1.4756.20.160.20.1.32 | ColumnfE1TimeSlot6Local | read-write | current | Local FRM220-E1/ET100 Series card timeslot6: 0:Inactive 1:Active |
| 1.3.6.1.4.1.4756.20.160.20.1.33 | ColumnfE1TimeSlot7Local | read-write | current | Local FRM220-E1/ET100 Series card timeslot7: 0:Inactive 1:Active |
| 1.3.6.1.4.1.4756.20.160.20.1.34 | ColumnfE1TimeSlot8Local | read-write | current | Local FRM220-E1/ET100 Series card timeslot8: 0:Inactive 1:Active |
| 1.3.6.1.4.1.4756.20.160.20.1.35 | ColumnfE1TimeSlot9Local | read-write | current | Local FRM220-E1/ET100 Series card timeslot9: 0:Inactive 1:Active |
| 1.3.6.1.4.1.4756.20.160.20.1.36 | ColumnfE1TimeSlot10Local | read-write | current | Local FRM220-E1/ET100 Series card timeslot10: 0:Inactive 1:Active |
| 1.3.6.1.4.1.4756.20.160.20.1.37 | ColumnfE1TimeSlot11Local | read-write | current | Local FRM220-E1/ET100 Series card timeslot11: 0:Inactive 1:Active |
| 1.3.6.1.4.1.4756.20.160.20.1.38 | ColumnfE1TimeSlot12Local | read-write | current | Local FRM220-E1/ET100 Series card timeslot12: 0:Inactive 1:Active |
| 1.3.6.1.4.1.4756.20.160.20.1.39 | ColumnfE1TimeSlot13Local | read-write | current | Local FRM220-E1/ET100 Series card timeslot13: 0:Inactive 1:Active |
| 1.3.6.1.4.1.4756.20.160.20.1.40 | ColumnfE1TimeSlot14Local | read-write | current | Local FRM220-E1/ET100 Series card timeslot14: 0:Inactive 1:Active |
| 1.3.6.1.4.1.4756.20.160.20.1.41 | ColumnfE1TimeSlot15Local | read-write | current | Local FRM220-E1 Series card timeslot15: 0:Inactive 1:Active |
| 1.3.6.1.4.1.4756.20.160.20.1.42 | ColumnfE1TimeSlot16Local | read-write | current | Local FRM220-E1 Series card timeslot16: 0:Inactive 1:Active |
| 1.3.6.1.4.1.4756.20.160.20.1.43 | ColumnfE1TimeSlot17Local | read-write | current | Local FRM220-E1/ET100 Series card timeslot17: 0:Inactive 1:Active |
| 1.3.6.1.4.1.4756.20.160.20.1.44 | ColumnfE1TimeSlot18Local | read-write | current | Local FRM220-E1/ET100 Series card timeslot18: 0:Inactive 1:Active |
| 1.3.6.1.4.1.4756.20.160.20.1.45 | ColumnfE1TimeSlot19Local | read-write | current | Local FRM220-E1/ET100 Series card timeslot19: 0:Inactive 1:Active |
| 1.3.6.1.4.1.4756.20.160.20.1.46 | ColumnfE1TimeSlot20Local | read-write | current | Local FRM220-E1/ET100 Series card timeslot20: 0:Inactive 1:Active |
| 1.3.6.1.4.1.4756.20.160.20.1.47 | ColumnfE1TimeSlot21Local | read-write | current | Local FRM220-E1/ET100 Series card timeslot21: 0:Inactive 1:Active |
| 1.3.6.1.4.1.4756.20.160.20.1.48 | ColumnfE1TimeSlot22Local | read-write | current | Local FRM220-E1/ET100 Series card timeslot22: 0:Inactive 1:Active |
| 1.3.6.1.4.1.4756.20.160.20.1.49 | ColumnfE1TimeSlot23Local | read-write | current | Local FRM220-E1/ET100 Series card timeslot23: 0:Inactive 1:Active |
| 1.3.6.1.4.1.4756.20.160.20.1.50 | ColumnfE1TimeSlot24Local | read-write | current | Local FRM220-E1/ET100 Series card timeslot24: 0:Inactive 1:Active |
| 1.3.6.1.4.1.4756.20.160.20.1.51 | ColumnfE1TimeSlot25Local | read-write | current | Local FRM220-E1/ET100 Series card timeslot25: 0:Inactive 1:Active |
| 1.3.6.1.4.1.4756.20.160.20.1.52 | ColumnfE1TimeSlot26Local | read-write | current | Local FRM220-E1/ET100 Series card timeslot26: 0:Inactive 1:Active |
| 1.3.6.1.4.1.4756.20.160.20.1.53 | ColumnfE1TimeSlot27Local | read-write | current | Local FRM220-E1/ET100 Series card timeslot27: 0:Inactive 1:Active |
| 1.3.6.1.4.1.4756.20.160.20.1.54 | ColumnfE1TimeSlot28Local | read-write | current | Local FRM220-E1/ET100 Series card timeslot28: 0:Inactive 1:Active |
| 1.3.6.1.4.1.4756.20.160.20.1.55 | ColumnfE1TimeSlot29Local | read-write | current | Local FRM220-E1/ET100 Series card timeslot29: 0:Inactive 1:Active |
| 1.3.6.1.4.1.4756.20.160.20.1.56 | ColumnfE1TimeSlot30Local | read-write | current | Local FRM220-E1/ET100 Series card timeslot30: 0:Inactive 1:Active |
| 1.3.6.1.4.1.4756.20.160.20.1.57 | ColumnfE1TimeSlot31Local | read-write | current | Local FRM220-E1/ET100 Series card timeslot31: 0:Inactive 1:Active |
| 1.3.6.1.4.1.4756.20.160.20.1.58 | ColumnfE1TimeSourceLocal | read-write | current | Local FRM220-E1/ET100 Series card time souce: 0:Recovery from E1 1:Internal oscillator |
| 1.3.6.1.4.1.4756.20.160.20.1.59 | ColumnfE1FramerLocal | read-write | current | Local FRM220-E1/ET100 Series card E1 framer: 0:CCS 1:CAS |
| 1.3.6.1.4.1.4756.20.160.20.1.60 | ColumnfE1LinecodeLocal | read-write | current | Local FRM220-E1/ET100 Series card E1 line code: 0:HDB3 1:AMI |
| 1.3.6.1.4.1.4756.20.160.20.1.61 | ColumnfE1LineImpedanceLocal | read-write | current | Local FRM220-E1/ET100 Series card E1 line impedance: 0:120 ohms 1:75 ohms |
| 1.3.6.1.4.1.4756.20.160.20.1.62 | ColumnfE1IdelCodeLocal | read-write | current | Local FRM220-E1/ET100 Series card E1 unused timeslot code: 0:0x7E 1:0xFF |
| 1.3.6.1.4.1.4756.20.160.20.1.63 | ColumnfE1AisLocal | read-write | current | Local FRM220-E1/ET100 Series card E1 AIS: 0:Disable 1:Enable |
| 1.3.6.1.4.1.4756.20.160.20.1.64 | ColumnfE1LbsettingLocal | read-write | current | Local FRM220-E1/ET100 Series card loop back test: 0:OFF 1:RLB 2:RRLB |
| 1.3.6.1.4.1.4756.20.160.20.1.65 | ColumnfE1BertLocal | read-write | current | Local FRM220-E1/ET100 Series card bert test: 0:Disable 1:Enable |
| 1.3.6.1.4.1.4756.20.160.20.1.66 | ColumnfE1CounterCrlLocal | read-write | current | Local FRM220-E1/ET100 Series card counter control: 0:Disable 1:Enable |
| 1.3.6.1.4.1.4756.20.160.20.1.67 | ColumnfE1RmonInLocal | read-only | current | Local FRM220-E1/ET100 Series card RMON Rx counter: |
| 1.3.6.1.4.1.4756.20.160.20.1.68 | ColumnfE1RmonOutLocal | read-only | current | Local FRM220-E1/ET100 Series card RMON Rx counter: |
| 1.3.6.1.4.1.4756.20.160.20.1.69 | ColumnfE1CrlRmonCntsRxLocal | read-write | current | Local FRM220-E1/ET100 Series card clear RMON Rx: 0:NO 1:Clear |
| 1.3.6.1.4.1.4756.20.160.20.1.70 | ColumnfE1CrlRmonCntsTxLocal | read-write | current | Local FRM220-E1/ET100 Series card clear RMON Tx: 0:NO 1:Clear |
| 1.3.6.1.4.1.4756.20.160.20.1.71 | ColumnfE1TestSTSLocal | read-only | current | Local FRM220-E1/ET100 Series card test status: 0:Normal 1:In test |
| 1.3.6.1.4.1.4756.20.160.20.1.72 | ColumnfE1AlarmSTSLocal | read-only | current | Local FRM220-E1/ET100 Series card E1 alarm status: 0:No 1:Have |
| 1.3.6.1.4.1.4756.20.161 | NodefE1RemoteCards | |||
| 1.3.6.1.4.1.4756.20.161.20 | TablefE1RemoteTable | not-accessible | current | A list of local FRM220-E1-ET100 series card entries. The number of entries is fE1-No-L. |
| 1.3.6.1.4.1.4756.20.161.20.1 | RowfE1RemoteEntry | not-accessible | current | An entry containing management information applicable to a particular local FRM220-E1/ET100 series card. |
| 1.3.6.1.4.1.4756.20.161.20.1.1 | ColumnfE1ChassisIndexRemote | read-only | current | A unique value for each local card. It is the chassis location number. |
| 1.3.6.1.4.1.4756.20.161.20.1.2 | ColumnfE1SlotIndexRemote | read-only | current | A unique value for each local card. It is the slot location number. |
| 1.3.6.1.4.1.4756.20.161.20.1.3 | ColumnfE1CardHWVerRemote | read-only | current | Remote FRM220-E1/ET100 Series card hardware version x.xxx |
| 1.3.6.1.4.1.4756.20.161.20.1.4 | ColumnfE1CardFWVerRemote | read-only | current | Remote FRM220-E1/ET100 Series card firmware version x.xxx |
| 1.3.6.1.4.1.4756.20.161.20.1.5 | ColumnfE1CardCPLDVerRemote | read-only | current | Remote FRM220-E1/ET100 Series card CPLD version x.xxx |
| 1.3.6.1.4.1.4756.20.161.20.1.6 | ColumnfE1CardFPGAVerRemote | read-only | current | Remote FRM220-E1/ET100 Series card FPGA version x.xxx |
| 1.3.6.1.4.1.4756.20.161.20.1.7 | ColumnfE1PortActiveRemote | read-only | current | Remote FRM220-E1/ET100 Series card active: 0:Disable 1:Enable |
| 1.3.6.1.4.1.4756.20.161.20.1.8 | ColumnfE1PortResetRemote | read-write | current | Remote FRM220-E1/ET100 Series card portreset: 0:OFF 1:Action |
| 1.3.6.1.4.1.4756.20.161.20.1.9 | ColumnfE1SettoDefaultRemote | read-write | current | Remote FRM220-E1/ET100 Series card set to default: 0:OFF 1:Action |
| 1.3.6.1.4.1.4756.20.161.20.1.10 | ColumnfE1SignalRemote | read-only | current | Remote FRM220-E1/ET100 Series card E1 signal status: 0:Signal Loss 1:Normal |
| 1.3.6.1.4.1.4756.20.161.20.1.11 | ColumnfE1SyncRemote | read-only | current | Remote FRM220-E1/ET100 Series card E1 sync status: 0:Sync Loss 1:Normal |
| 1.3.6.1.4.1.4756.20.161.20.1.12 | ColumnfE1RdSTSRemote | read-only | current | Remote FRM220-E1/ET100 Series card RD status: 0:ON 1:OFF 2:Flash |
| 1.3.6.1.4.1.4756.20.161.20.1.13 | ColumnfE1TdSTSRemote | read-only | current | Remote FRM220-E1/ET100 Series card TD status: 0:ON 1:OFF 2:Flash |
| 1.3.6.1.4.1.4756.20.161.20.1.14 | ColumnfE1ReAisRemote | read-only | current | Remote FRM220-E1/ET100 Series card E1 receive AIS: 0:NO 1:Have |
| 1.3.6.1.4.1.4756.20.161.20.1.15 | ColumnfE1LOMFRemote | read-only | current | Remote FRM220-E1/ET100 Series card E1 loss of multiframe sync: 0:NO 1:Have |
| 1.3.6.1.4.1.4756.20.161.20.1.16 | ColumnfE1LinecodeViolationRemote | read-only | current | Remote FRM220-E1/ET100 Series card E1 line code violation: 0:NO 1:Have |
| 1.3.6.1.4.1.4756.20.161.20.1.17 | ColumnfE1BertErrRemote | read-only | current | Remote FRM220-E1/ET100 Series card E1 bert error: 0:NO 1:Have |
| 1.3.6.1.4.1.4756.20.161.20.1.18 | ColumnfE1RemoPwAbRemote | read-only | current | Remote FRM220-E1/ET100 Series card remote power fail: 0:OK 1:Failue |
| 1.3.6.1.4.1.4756.20.161.20.1.19 | ColumnfE1Utp1LinkRemote | read-only | current | Remote FRM220-E1/ET100 Series card utp link status: 0:Down 1:Lind up |
| 1.3.6.1.4.1.4756.20.161.20.1.20 | ColumnfE1Utp1SpeedSTSRemote | read-only | current | Remote FRM220-E1/ET100 Series card utp1 speed status : 0:10M 1:100M |
| 1.3.6.1.4.1.4756.20.161.20.1.21 | ColumnfE1Utp1DuplexSTSRemote | read-only | current | Remote FRM220-E1/ET100 Series card utp1 duplex status : 0:Half 1:Full |
| 1.3.6.1.4.1.4756.20.161.20.1.22 | ColumnfE1Utp1NegRemote | read-write | current | Remote FRM220-E1/ET100 Series card utp1 negotiation : 0:Manual 1:Auto |
| 1.3.6.1.4.1.4756.20.161.20.1.23 | ColumnfE1Utp1SpeedRemote | read-write | current | Remote FRM220-E1/ET100 Series card utp1 speed: 0:10M 1:100M |
| 1.3.6.1.4.1.4756.20.161.20.1.24 | ColumnfE1Utp1DuplexRemote | read-write | current | Remote FRM220-E1/ET100 Series card utp1 duplex: 0:Half 1:Full |
| 1.3.6.1.4.1.4756.20.161.20.1.25 | ColumnfE1Utp1FlowCrlRemote | read-write | current | Remote FRM220-E1/ET100 Series card utp1 flow control: 0:Disable 1:Enable |
| 1.3.6.1.4.1.4756.20.161.20.1.26 | ColumnfE1FrameRemote | read-only | current | Remote FRM220-E1/ET100 Series card E1 frame: 0:Unframed 1:Framed |
| 1.3.6.1.4.1.4756.20.161.20.1.27 | ColumnfE1TimeSlot1Remote | read-write | current | Remote FRM220-E1/ET100 Series card timeslot1: 0:Inactive 1:Active |
| 1.3.6.1.4.1.4756.20.161.20.1.28 | ColumnfE1TimeSlot2Remote | read-write | current | Remote FRM220-E1/ET100 Series card timeslot2: 0:Inactive 1:Active |
| 1.3.6.1.4.1.4756.20.161.20.1.29 | ColumnfE1TimeSlot3Remote | read-write | current | Remote FRM220-E1/ET100 Series card timeslot3: 0:Inactive 1:Active |
| 1.3.6.1.4.1.4756.20.161.20.1.30 | ColumnfE1TimeSlot4Remote | read-write | current | Remote FRM220-E1/ET100 Series card timeslot4: 0:Inactive 1:Active |
| 1.3.6.1.4.1.4756.20.161.20.1.31 | ColumnfE1TimeSlot5Remote | read-write | current | Remote FRM220-E1/ET100 Series card timeslot5: 0:Inactive 1:Active |
| 1.3.6.1.4.1.4756.20.161.20.1.32 | ColumnfE1TimeSlot6Remote | read-write | current | Remote FRM220-E1/ET100 Series card timeslot6: 0:Inactive 1:Active |
| 1.3.6.1.4.1.4756.20.161.20.1.33 | ColumnfE1TimeSlot7Remote | read-write | current | Remote FRM220-E1/ET100 Series card timeslot7: 0:Inactive 1:Active |
| 1.3.6.1.4.1.4756.20.161.20.1.34 | ColumnfE1TimeSlot8Remote | read-write | current | Remote FRM220-E1/ET100 Series card timeslot8: 0:Inactive 1:Active |
| 1.3.6.1.4.1.4756.20.161.20.1.35 | ColumnfE1TimeSlot9Remote | read-write | current | Remote FRM220-E1/ET100 Series card timeslot9: 0:Inactive 1:Active |
| 1.3.6.1.4.1.4756.20.161.20.1.36 | ColumnfE1TimeSlot10Remote | read-write | current | Remote FRM220-E1/ET100 Series card timeslot10: 0:Inactive 1:Active |
| 1.3.6.1.4.1.4756.20.161.20.1.37 | ColumnfE1TimeSlot11Remote | read-write | current | Remote FRM220-E1/ET100 Series card timeslot11: 0:Inactive 1:Active |
| 1.3.6.1.4.1.4756.20.161.20.1.38 | ColumnfE1TimeSlot12Remote | read-write | current | Remote FRM220-E1/ET100 Series card timeslot12: 0:Inactive 1:Active |
| 1.3.6.1.4.1.4756.20.161.20.1.39 | ColumnfE1TimeSlot13Remote | read-write | current | Remote FRM220-E1/ET100 Series card timeslot13: 0:Inactive 1:Active |
| 1.3.6.1.4.1.4756.20.161.20.1.40 | ColumnfE1TimeSlot14Remote | read-write | current | Remote FRM220-E1/ET100 Series card timeslot14: 0:Inactive 1:Active |
| 1.3.6.1.4.1.4756.20.161.20.1.41 | ColumnfE1TimeSlot15Remote | read-write | current | Remote FRM220-E1 Series card timeslot15: 0:Inactive 1:Active |
| 1.3.6.1.4.1.4756.20.161.20.1.42 | ColumnfE1TimeSlot16Remote | read-write | current | Remote FRM220-E1 Series card timeslot16: 0:Inactive 1:Active |
| 1.3.6.1.4.1.4756.20.161.20.1.43 | ColumnfE1TimeSlot17Remote | read-write | current | Remote FRM220-E1/ET100 Series card timeslot17: 0:Inactive 1:Active |
| 1.3.6.1.4.1.4756.20.161.20.1.44 | ColumnfE1TimeSlot18Remote | read-write | current | Remote FRM220-E1/ET100 Series card timeslot18: 0:Inactive 1:Active |
| 1.3.6.1.4.1.4756.20.161.20.1.45 | ColumnfE1TimeSlot19Remote | read-write | current | Remote FRM220-E1/ET100 Series card timeslot19: 0:Inactive 1:Active |
| 1.3.6.1.4.1.4756.20.161.20.1.46 | ColumnfE1TimeSlot20Remote | read-write | current | Remote FRM220-E1/ET100 Series card timeslot20: 0:Inactive 1:Active |
| 1.3.6.1.4.1.4756.20.161.20.1.47 | ColumnfE1TimeSlot21Remote | read-write | current | Remote FRM220-E1/ET100 Series card timeslot21: 0:Inactive 1:Active |
| 1.3.6.1.4.1.4756.20.161.20.1.48 | ColumnfE1TimeSlot22Remote | read-write | current | Remote FRM220-E1/ET100 Series card timeslot22: 0:Inactive 1:Active |
| 1.3.6.1.4.1.4756.20.161.20.1.49 | ColumnfE1TimeSlot23Remote | read-write | current | Remote FRM220-E1/ET100 Series card timeslot23: 0:Inactive 1:Active |
| 1.3.6.1.4.1.4756.20.161.20.1.50 | ColumnfE1TimeSlot24Remote | read-write | current | Remote FRM220-E1/ET100 Series card timeslot24: 0:Inactive 1:Active |
| 1.3.6.1.4.1.4756.20.161.20.1.51 | ColumnfE1TimeSlot25Remote | read-write | current | Remote FRM220-E1/ET100 Series card timeslot25: 0:Inactive 1:Active |
| 1.3.6.1.4.1.4756.20.161.20.1.52 | ColumnfE1TimeSlot26Remote | read-write | current | Remote FRM220-E1/ET100 Series card timeslot26: 0:Inactive 1:Active |
| 1.3.6.1.4.1.4756.20.161.20.1.53 | ColumnfE1TimeSlot27Remote | read-write | current | Remote FRM220-E1/ET100 Series card timeslot27: 0:Inactive 1:Active |
| 1.3.6.1.4.1.4756.20.161.20.1.54 | ColumnfE1TimeSlot28Remote | read-write | current | Remote FRM220-E1/ET100 Series card timeslot28: 0:Inactive 1:Active |
| 1.3.6.1.4.1.4756.20.161.20.1.55 | ColumnfE1TimeSlot29Remote | read-write | current | Remote FRM220-E1/ET100 Series card timeslot29: 0:Inactive 1:Active |
| 1.3.6.1.4.1.4756.20.161.20.1.56 | ColumnfE1TimeSlot30Remote | read-write | current | Remote FRM220-E1/ET100 Series card timeslot30: 0:Inactive 1:Active |
| 1.3.6.1.4.1.4756.20.161.20.1.57 | ColumnfE1TimeSlot31Remote | read-write | current | Remote FRM220-E1/ET100 Series card timeslot31: 0:Inactive 1:Active |
| 1.3.6.1.4.1.4756.20.161.20.1.58 | ColumnfE1TimeSourceRemote | read-write | current | Remote FRM220-E1/ET100 Series card time souce: 0:Recovery from E1 1:Internal oscillator |
| 1.3.6.1.4.1.4756.20.161.20.1.59 | ColumnfE1FramerRemote | read-write | current | Remote FRM220-E1/ET100 Series card E1 framer: 0:CCS 1:CAS |
| 1.3.6.1.4.1.4756.20.161.20.1.60 | ColumnfE1LinecodeRemote | read-write | current | Remote FRM220-E1/ET100 Series card E1 line code: 0:HDB3 1:AMI |
| 1.3.6.1.4.1.4756.20.161.20.1.61 | ColumnfE1LineImpedanceRemote | read-write | current | Remote FRM220-E1/ET100 Series card E1 line impedance: 0:120 ohms 1:75 ohms |
| 1.3.6.1.4.1.4756.20.161.20.1.62 | ColumnfE1IdelCodeRemote | read-write | current | Remote FRM220-E1/ET100 Series card E1 unused timeslot code: 0:0x7E 1:0xFF |
| 1.3.6.1.4.1.4756.20.161.20.1.63 | ColumnfE1AisRemote | read-write | current | Remote FRM220-E1/ET100 Series card E1 AIS: 0:Disable 1:Enable |
| 1.3.6.1.4.1.4756.20.161.20.1.64 | ColumnfE1CounterCrlRemote | read-write | current | Remote FRM220-E1/ET100 Series card counter control: 0:Disable 1:Enable |
| 1.3.6.1.4.1.4756.20.161.20.1.65 | ColumnfE1RmonInRemote | read-only | current | Remote FRM220-E1/ET100 Series card RMON Rx counter: |
| 1.3.6.1.4.1.4756.20.161.20.1.66 | ColumnfE1RmonOutRemote | read-only | current | Remote FRM220-E1/ET100 Series card RMON Rx counter: |
| 1.3.6.1.4.1.4756.20.161.20.1.67 | ColumnfE1CrlRmonCntsRxRemote | read-write | current | Remote FRM220-E1/ET100 Series card clear RMON Rx: 0:NO 1:Clear |
| 1.3.6.1.4.1.4756.20.161.20.1.68 | ColumnfE1CrlRmonCntsTxRemote | read-write | current | Remote FRM220-E1/ET100 Series card clear RMON Tx: 0:NO 1:Clear |
| 1.3.6.1.4.1.4756.20.161.20.1.69 | ColumnfE1TestSTSRemote | read-only | current | Remote FRM220-E1/ET100 Series card test status: 0:Normal 1:In test |
| 1.3.6.1.4.1.4756.20.161.20.1.70 | ColumnfE1AlarmSTSRemote | read-only | current | Remote FRM220-E1/ET100 Series card E1 alarm status: 0:No 1:Have |
| 1.3.6.1.4.1.4756.20.170 | Nodef1000EDSCards | |||
| 1.3.6.1.4.1.4756.20.170.20 | Tablef1000EDSTable | not-accessible | current | A list of local frm220-1000EDS card entries. The number of entries is f1000EDS-No. |
| 1.3.6.1.4.1.4756.20.170.20.1 | Rowf1000EDSEntry | not-accessible | current | An entry containing management information applicable to a particular local FRM-1000EDS card. |
| 1.3.6.1.4.1.4756.20.170.20.1.1 | Columnf1000EDSChassisIndex | read-only | current | A unique value for each local card. It is the chassis location number. |
| 1.3.6.1.4.1.4756.20.170.20.1.2 | Columnf1000EDSSlotIndex | read-only | current | A unique value for each local card. It is the slot location number. |
| 1.3.6.1.4.1.4756.20.170.20.1.3 | Columnf1000EDSCardHWVer | read-only | current | device card hardware version x.xxx |
| 1.3.6.1.4.1.4756.20.170.20.1.4 | Columnf1000EDSCardFWVer | read-only | current | device card firmware version x.xxx |
| 1.3.6.1.4.1.4756.20.170.20.1.5 | Columnf1000EDSCardCPLDVer | read-only | current | device card CPLD version x.xxx |
| 1.3.6.1.4.1.4756.20.170.20.1.6 | Columnf1000EDSCardFPGAVer | read-only | current | device card FPGA version x.xxx |
| 1.3.6.1.4.1.4756.20.170.20.1.7 | Columnf1000EDSModel | read-only | current | frm220 f1000EDS Serial Type |
| 1.3.6.1.4.1.4756.20.170.20.1.8 | Columnf1000EDSFx1Link | read-only | current | device card fiber port 1 link status: 0:Down 1:Up |
| 1.3.6.1.4.1.4756.20.170.20.1.9 | Columnf1000EDSFx1FEF | read-only | current | device card fiber port 1 detected Far End Fault: 0:Off 1:Detected |
| 1.3.6.1.4.1.4756.20.170.20.1.10 | Columnf1000EDSFx1RemoPwrAb | read-only | current | device card fiber port 1 Remote Power status: 0:Abnormal 1:OK |
| 1.3.6.1.4.1.4756.20.170.20.1.11 | Columnf1000EDSFx2Link | read-only | current | device card fiber port 2 link status: 0:Down 1:Up |
| 1.3.6.1.4.1.4756.20.170.20.1.12 | Columnf1000EDSFx2FEF | read-only | current | device card fiber port 2 detected Far End Fault: 0:Off 1:Detected |
| 1.3.6.1.4.1.4756.20.170.20.1.13 | Columnf1000EDSFx2RemoPwrAb | read-only | current | device card fiber port 2 Remote Power status: 0:Abnormal 1:OK |
| 1.3.6.1.4.1.4756.20.170.20.1.14 | Columnf1000EDSUtp1Link | read-only | current | device card UTP port 3 link status: 0:Down 1:Up |
| 1.3.6.1.4.1.4756.20.170.20.1.15 | Columnf1000EDSUtp1Nego | read-write | current | device card UTP port 3 negotiation status: 0:Manual 1:Auto |
| 1.3.6.1.4.1.4756.20.170.20.1.16 | Columnf1000EDSUtp1Speed | read-write | current | device card UTP port 3 speed status: 0:10 Base-T 1:100 Base-TX 2:1000 Base-TX |
| 1.3.6.1.4.1.4756.20.170.20.1.17 | Columnf1000EDSUtp1Duplex | read-write | current | device card UTP port 3 duplex status: 0:Half duplex mode 1:Full duplex mode |
| 1.3.6.1.4.1.4756.20.170.20.1.18 | Columnf1000EDSUtp2Link | read-only | current | device card UTP port 4 link status: 0:Down 1:Up |
| 1.3.6.1.4.1.4756.20.170.20.1.19 | Columnf1000EDSUtp2Nego | read-write | current | device card UTP port 4 negotiation status: 0:Manual 1:Auto |
| 1.3.6.1.4.1.4756.20.170.20.1.20 | Columnf1000EDSUtp2Speed | read-write | current | device card UTP port 4 speed status: 0:10 Base-T 1:100 Base-TX 2:1000 Base-TX |
| 1.3.6.1.4.1.4756.20.170.20.1.21 | Columnf1000EDSUtp2Duplex | read-write | current | device card UTP port 4 duplex status: 0:Half duplex mode 1:Full duplex mode |
| 1.3.6.1.4.1.4756.20.170.20.1.22 | Columnf1000EDSFx1IrlMode | read-write | current | device card port 1 Ingress Rate Limit mode: (Ingress data rate limit for priority 0 frames.) 0:No limit 1:limited |
| 1.3.6.1.4.1.4756.20.170.20.1.23 | Columnf1000EDSFx1IrlIndex | read-write | current | device card port 1 Ingress Rate Limit index: Index Limit Rate Index Limit Rate 0 Disable 16 1M 1 250M 17 960K 2 140M 18 896K 3 95M 19 832K 4 57M 20 768K 5 40M … |
| 1.3.6.1.4.1.4756.20.170.20.1.24 | Columnf1000EDSFx1ErlIndex | read-write | current | device card port 1 Egress Rate Limit index: Index Limit Rate Index Limit Rate 0 Disable 16 1M 1 250M 17 960K 2 140M 18 896K 3 95M 19 832K 4 57M 20 768K 5 40M 2… |
| 1.3.6.1.4.1.4756.20.170.20.1.25 | Columnf1000EDSFx2IrlMode | read-write | current | device card port 2 Ingress Rate Limit mode: (Ingress data rate limit for priority 0 frames.) 0:No limit 1:limited |
| 1.3.6.1.4.1.4756.20.170.20.1.26 | Columnf1000EDSFx2IrlIndex | read-write | current | device card port 2 Ingress Rate Limit index: Index Limit Rate Index Limit Rate 0 Disable 16 1M 1 250M 17 960K 2 140M 18 896K 3 95M 19 832K 4 57M 20 768K 5 40M … |
| 1.3.6.1.4.1.4756.20.170.20.1.27 | Columnf1000EDSFx2ErlIndex | read-write | current | device card port 2 Egress Rate Limit index: Index Limit Rate Index Limit Rate 0 Disable 16 1M 1 250M 17 960K 2 140M 18 896K 3 95M 19 832K 4 57M 20 768K 5 40M 2… |
| 1.3.6.1.4.1.4756.20.170.20.1.28 | Columnf1000EDSUtp1IrlMode | read-write | current | device card port 3 Ingress Rate Limit mode: (Ingress data rate limit for priority 0 frames.) 0:No limit 1:limited |
| 1.3.6.1.4.1.4756.20.170.20.1.29 | Columnf1000EDSUtp1IrlIndex | read-write | current | device card port 3 Ingress Rate Limit index: Index Limit Rate Index Limit Rate 0 Disable 16 1M 1 250M 17 960K 2 140M 18 896K 3 95M 19 832K 4 57M 20 768K 5 40M … |
| 1.3.6.1.4.1.4756.20.170.20.1.30 | Columnf1000EDSUtp1ErlIndex | read-write | current | device card port 3 Egress Rate Limit index: Index Limit Rate Index Limit Rate 0 Disable 16 1M 1 250M 17 960K 2 140M 18 896K 3 95M 19 832K 4 57M 20 768K 5 40M 2… |
| 1.3.6.1.4.1.4756.20.170.20.1.31 | Columnf1000EDSUtp2IrlMode | read-write | current | device card port 4 Ingress Rate Limit mode: (Ingress data rate limit for priority 0 frames.) 0:No limit 1:limited |
| 1.3.6.1.4.1.4756.20.170.20.1.32 | Columnf1000EDSUtp2IrlIndex | read-write | current | device card port 4 Ingress Rate Limit index: Index Limit Rate Index Limit Rate 0 Disable 16 1M 1 250M 17 960K 2 140M 18 896K 3 95M 19 832K 4 57M 20 768K 5 40M … |
| 1.3.6.1.4.1.4756.20.170.20.1.33 | Columnf1000EDSUtp2ErlIndex | read-write | current | device card port 4 Egress Rate Limit index: Index Limit Rate Index Limit Rate 0 Disable 16 1M 1 250M 17 960K 2 140M 18 896K 3 95M 19 832K 4 57M 20 768K 5 40M 2… |
| 1.3.6.1.4.1.4756.20.170.20.1.34 | Columnf1000EDSDeviceActive | read-write | current | device card active mode: (It is read-only in local device.) 0:Disable 1:Enable |
| 1.3.6.1.4.1.4756.20.170.20.1.35 | Columnf1000EDSDeviceReset | read-write | current | Force local device card to reset mode: 0:Off 1:Action |
| 1.3.6.1.4.1.4756.20.170.20.1.36 | Columnf1000EDSFx1Active | read-write | current | device fiber port 1 active mode: 0:Disable 1:Enable |
| 1.3.6.1.4.1.4756.20.170.20.1.37 | Columnf1000EDSFx2Active | read-write | current | device fiber port 2 active mode: 0:Disable 1:Enable |
| 1.3.6.1.4.1.4756.20.170.20.1.38 | Columnf1000EDSUtp1Active | read-write | current | device UTP port 3 active mode: 0:Disable 1:Enable |
| 1.3.6.1.4.1.4756.20.170.20.1.39 | Columnf1000EDSUtp2Active | read-write | current | device UTP port 4 active mode: 0:Disable 1:Enable |
| 1.3.6.1.4.1.4756.20.170.20.1.40 | Columnf1000EDSOperationMode | read-write | current | device operation mode setting 0:Switch Mode 1:Port VLAN Mode |
| 1.3.6.1.4.1.4756.20.170.20.1.41 | Columnf1000EDSLfpMode1 | read-write | current | device card port 1 Link Fault Pass Through: 0:Disable 1:Enable |
| 1.3.6.1.4.1.4756.20.170.20.1.42 | Columnf1000EDSLfpMode2 | read-write | current | device card port 2 Link Fault Pass Through: 0:Disable 1:Enable |
| 1.3.6.1.4.1.4756.20.170.20.1.43 | Columnf1000EDSFx1AlsMode1 | read-write | current | device card port 1 Auto Laser Shutdown mode: 0:Disable 1:Enable |
| 1.3.6.1.4.1.4756.20.170.20.1.44 | Columnf1000EDSFx2AlsMode2 | read-write | current | device card port 2 Auto Laser Shutdown mode: 0:Disable 1:Enable |
| 1.3.6.1.4.1.4756.20.170.20.1.45 | Columnf1000EDSClrRMONCnts | read-write | current | Clear local device card RMON IN/OUT counters: 0:No action 1:Action |
| 1.3.6.1.4.1.4756.20.170.20.1.46 | Columnf1000EDSFx1InfoROM1 | read-only | current | device card port 1 INFORemoteOM information 1 valid: 0:Invalid 1:Valid |
| 1.3.6.1.4.1.4756.20.170.20.1.47 | Columnf1000EDSFx1InfoROM2 | read-only | current | device card port 1 INFORemoteOM information 2 valid: 0:Invalid 1:Valid(replacing D/D function |
| 1.3.6.1.4.1.4756.20.170.20.1.48 | Columnf1000EDSFx2InfoROM2 | read-only | current | device card port 2 INFORemoteOM information 2 valid: 0:Invalid 1:Valid(replacing D/D function) |
| 1.3.6.1.4.1.4756.20.170.20.1.49 | Columnf1000EDSFx1InfoSN1 | read-only | current | device card port 1 INFORemoteOM S/N 1 |
| 1.3.6.1.4.1.4756.20.170.20.1.50 | Columnf1000EDSFx1InfoSN2 | read-only | current | device card port 1 INFORemoteOM S/N 2 |
| 1.3.6.1.4.1.4756.20.170.20.1.51 | Columnf1000EDSFx2InfoSN1 | read-only | current | device card port 2 INFORemoteOM S/N 1 |
| 1.3.6.1.4.1.4756.20.170.20.1.52 | Columnf1000EDSFx2InfoSN2 | read-only | current | device card port 2 INFORemoteOM S/N 2 |
| 1.3.6.1.4.1.4756.20.170.20.1.53 | Columnf1000EDSFx1DD | read-only | current | device card fiber port 1 Digital Diagnostic function: 0:No 1:Yes |
| 1.3.6.1.4.1.4756.20.170.20.1.54 | Columnf1000EDSFx1DDVendor | read-only | current | device card fiber port 1 D/D information: Vendor name |
| 1.3.6.1.4.1.4756.20.170.20.1.55 | Columnf1000EDSFx1DDPartNo | read-only | current | device card fiber port 1 D/D information: Vendor part number |
| 1.3.6.1.4.1.4756.20.170.20.1.56 | Columnf1000EDSFx1DDFiberType | read-only | current | device card fiber port 1 D/D information: Fiber Type |
| 1.3.6.1.4.1.4756.20.170.20.1.57 | Columnf1000EDSFx1DDWaveLen | read-only | current | device card fiber port 1 D/D information: Wave length |
| 1.3.6.1.4.1.4756.20.170.20.1.58 | Columnf1000EDSFx1DDWaveLen2 | read-only | current | device card fiber port 1 D/D information: Wave length 2 |
| 1.3.6.1.4.1.4756.20.170.20.1.59 | Columnf1000EDSFx1DDLinkLen | read-only | current | device card fiber port 1 D/D information: Link length |
| 1.3.6.1.4.1.4756.20.170.20.1.60 | Columnf1000EDSFx1DDLenUnit | read-only | current | device card fiber port 1 D/D information: Length Unit |
| 1.3.6.1.4.1.4756.20.170.20.1.61 | Columnf1000EDSFx1DDStatus | read-only | current | device card fiber port 1 D/D information: Status Support |
| 1.3.6.1.4.1.4756.20.170.20.1.62 | Columnf1000EDSFx1DDRxSens | read-only | current | device card fiber port 1 D/D information: Rx Sensitivity |
| 1.3.6.1.4.1.4756.20.170.20.1.63 | Columnf1000EDSFx1DDTxPWR | read-only | current | device card fiber port 1 D/D information: Tx power |
| 1.3.6.1.4.1.4756.20.170.20.1.64 | Columnf1000EDSFx1DDRxPWR | read-only | current | device card fiber port 1 D/D information: Rx power |
| 1.3.6.1.4.1.4756.20.170.20.1.65 | Columnf1000EDSFx1DDTemp | read-only | current | device card fiber port 1 D/D information: Temperature in degree C |
| 1.3.6.1.4.1.4756.20.170.20.1.66 | Columnf1000EDSFx1DDPWRMargin | read-only | current | device card fiber port 1 D/D information: Power margin |
| 1.3.6.1.4.1.4756.20.170.20.1.67 | Columnf1000EDSFx2DD | read-only | current | device card fiber port 2 Digital Diagnostic function: 0:No 1:Yes |
| 1.3.6.1.4.1.4756.20.170.20.1.68 | Columnf1000EDSFx2DDVendor | read-only | current | device card fiber port 2 D/D information: Vendor name |
| 1.3.6.1.4.1.4756.20.170.20.1.69 | Columnf1000EDSFx2DDPartNo | read-only | current | device card fiber port 2 D/D information: Vendor part number |
| 1.3.6.1.4.1.4756.20.170.20.1.70 | Columnf1000EDSFx2DDFiberType | read-only | current | device card fiber port 2 D/D information: Fiber Type |
| 1.3.6.1.4.1.4756.20.170.20.1.71 | Columnf1000EDSFx2DDWaveLen | read-only | current | device card fiber port 2 D/D information: Wave length |
| 1.3.6.1.4.1.4756.20.170.20.1.72 | Columnf1000EDSFx2DDWaveLen2 | read-only | current | device card fiber port 2 D/D information: Wave length 2 |
| 1.3.6.1.4.1.4756.20.170.20.1.73 | Columnf1000EDSFx2DDLinkLen | read-only | current | device card fiber port 2 D/D information: Link length |
| 1.3.6.1.4.1.4756.20.170.20.1.74 | Columnf1000EDSFx2DDLenUnit | read-only | current | device card fiber port 2 D/D information: Length Unit |
| 1.3.6.1.4.1.4756.20.170.20.1.75 | Columnf1000EDSFx2DDStatus | read-only | current | device card fiber port 2 D/D information: Status Support |
| 1.3.6.1.4.1.4756.20.170.20.1.76 | Columnf1000EDSFx2DDRxSens | read-only | current | device card fiber port 2 D/D information: Rx Sensitivity |
| 1.3.6.1.4.1.4756.20.170.20.1.77 | Columnf1000EDSFx2DDTxPWR | read-only | current | device card fiber port 2 D/D information: Tx power |
| 1.3.6.1.4.1.4756.20.170.20.1.78 | Columnf1000EDSFx2DDRxPWR | read-only | current | device card fiber port 2 D/D information: Rx power |
| 1.3.6.1.4.1.4756.20.170.20.1.79 | Columnf1000EDSFx2DDTemp | read-only | current | device card fiber port 2 D/D information: Temperature in degree C |
| 1.3.6.1.4.1.4756.20.170.20.1.80 | Columnf1000EDSFx2DDPWRMargin | read-only | current | device card fiber port 2 D/D information: Power margin |
| 1.3.6.1.4.1.4756.20.170.20.1.81 | Columnf1000EDSFx1RMONIn | read-only | current | device card port 1 RMON IN counter. |
| 1.3.6.1.4.1.4756.20.170.20.1.82 | Columnf1000EDSFx1RMONOut | read-only | current | device card port 1 RMON OUT counter. |
| 1.3.6.1.4.1.4756.20.170.20.1.83 | Columnf1000EDSFx2RMONIn | read-only | current | device card port 2 RMON IN counter. |
| 1.3.6.1.4.1.4756.20.170.20.1.84 | Columnf1000EDSFx2RMONOut | read-only | current | device card port 2 RMON OUT counter. |
| 1.3.6.1.4.1.4756.20.170.20.1.85 | Columnf1000EDSUtp1RMONIn | read-only | current | device card port 3 RMON IN counter. |
| 1.3.6.1.4.1.4756.20.170.20.1.86 | Columnf1000EDSUtp1RMONOut | read-only | current | device card port 3 RMON OUT counter. |
| 1.3.6.1.4.1.4756.20.170.20.1.87 | Columnf1000EDSUtp2RMONIn | read-only | current | device card port 4 RMON IN counter. |
| 1.3.6.1.4.1.4756.20.170.20.1.88 | Columnf1000EDSUtp2RMONOut | read-only | current | device card port 4 RMON OUT counter. |
| 1.3.6.1.4.1.4756.20.170.20.1.89 | Columnf1000EDSSetDefault | read-write | current | device card set to default 0:OFF 1:Action |
| 1.3.6.1.4.1.4756.20.180 | Nodef100ISLocalCards | |||
| 1.3.6.1.4.1.4756.20.180.20 | Tablef100ISLocalTable | not-accessible | current | A list of local FRM220-10/100IS-2 card entries. The number of entries is f100IS-No-L. |
| 1.3.6.1.4.1.4756.20.180.20.1 | Rowf100ISLocalEntry | not-accessible | current | An entry containing management information applicable to a particular local FRM220-10/100IS-2 card. |
| 1.3.6.1.4.1.4756.20.180.20.1.1 | Columnf100ISChassisIndexLocal | read-only | current | A unique value for each local card. It is the chassis location number. |
| 1.3.6.1.4.1.4756.20.180.20.1.2 | Columnf100ISSlotIndexLocal | read-only | current | A unique value for each local card. It is the slot location number. |
| 1.3.6.1.4.1.4756.20.180.20.1.3 | Columnf100ISCardHWVerLocal | read-only | current | Local FRM220-10/100I card hardware version x.xxx |
| 1.3.6.1.4.1.4756.20.180.20.1.4 | Columnf100ISCardFWVerLocal | read-only | current | Local FRM220-10/100I card firmware version x.xxx |
| 1.3.6.1.4.1.4756.20.180.20.1.5 | Columnf100ISCardCPLDVerLocal | read-only | current | Local FRM220-10/100I card CPLD version x.xxx |
| 1.3.6.1.4.1.4756.20.180.20.1.6 | Columnf100ISCardFPGAVerLocal | read-only | current | Local FRM220-10/100I card FPGA version x.xxx |
| 1.3.6.1.4.1.4756.20.180.20.1.7 | Columnf100ISFx1PortActiveLocal | read-write | current | Local FRM220-10/100IS-2 card FX1 active: 0:Inactive 1:Active |
| 1.3.6.1.4.1.4756.20.180.20.1.8 | Columnf100ISFx2PortActiveLocal | read-write | current | Local FRM220-10/100IS-2 card FX2 active: 0:Inactive 1:Active |
| 1.3.6.1.4.1.4756.20.180.20.1.9 | Columnf100ISFx1InBandManagLocal | read-write | current | Local FRM220-10/100IS-2 card Fx1 manages remote: 0:Disable 1:Enable |
| 1.3.6.1.4.1.4756.20.180.20.1.10 | Columnf100ISFx2InBandManagLocal | read-write | current | Local FRM220-10/100IS-2 card Fx2 manages remote: 0:Disable 1:Enable |
| 1.3.6.1.4.1.4756.20.180.20.1.11 | Columnf100ISUtp3LinkLocal | read-only | current | Local FRM220-10/100IS-2 card UTP3 link status: 0:Down 1:Up |
| 1.3.6.1.4.1.4756.20.180.20.1.12 | Columnf100ISUtp4LinkLocal | read-only | current | Local FRM220-10/100IS-2 card UTP4 link status: 0:Down 1:Up |
| 1.3.6.1.4.1.4756.20.180.20.1.13 | Columnf100ISUtp3RxActLocal | read-only | current | Local FRM220-10/100IS-2 card UTP3 receive active status: 0:Off 1:On |
| 1.3.6.1.4.1.4756.20.180.20.1.14 | Columnf100ISUtp4RxActLocal | read-only | current | Local FRM220-10/100IS-2 card UTP4 receive active status: 0:Off 1:On |
| 1.3.6.1.4.1.4756.20.180.20.1.15 | Columnf100ISUtp3NegoLocal | read-write | current | Local FRM220-10/100IS-2 card UTP3 negotiation status: 0:Manual 1:Auto |
| 1.3.6.1.4.1.4756.20.180.20.1.16 | Columnf100ISUtp4NegoLocal | read-write | current | Local FRM220-10/100IS-2 card UTP4 negotiation status: 0:Manual 1:Auto |
| 1.3.6.1.4.1.4756.20.180.20.1.17 | Columnf100ISUtp3SpeedLocal | read-write | current | Local FRM220-10/100IS-2 card UTP3 speed: 0:10MHz 1:100MHz |
| 1.3.6.1.4.1.4756.20.180.20.1.18 | Columnf100ISUtp4SpeedLocal | read-write | current | Local FRM220-10/100IS-2 card UTP4 speed: 0:10MHz 1:100MHz |
| 1.3.6.1.4.1.4756.20.180.20.1.19 | Columnf100ISUtp3DuplexLocal | read-write | current | Local FRM220-10/100IS-2 card UTP3 duplex: 0:Half duplex mode 1:Full duplex mode |
| 1.3.6.1.4.1.4756.20.180.20.1.20 | Columnf100ISUtp4DuplexLocal | read-write | current | Local FRM220-10/100IS-2 card UTP4 duplex: 0:Half duplex mode 1:Full duplex mode |
| 1.3.6.1.4.1.4756.20.180.20.1.21 | Columnf100ISUtp3RxByteLocal | read-only | current | Local FRM220-10/100IS-2 card UTP3-in octet counter |
| 1.3.6.1.4.1.4756.20.180.20.1.22 | Columnf100ISUtp4RxByteLocal | read-only | current | Local FRM220-10/100IS-2 card UTP4-in octet counter |
| 1.3.6.1.4.1.4756.20.180.20.1.23 | Columnf100ISUtp3TxByteLocal | read-only | current | Local FRM220-10/100IS-2 card UTP3-out octet counter |
| 1.3.6.1.4.1.4756.20.180.20.1.24 | Columnf100ISUtp4TxByteLocal | read-only | current | Local FRM220-10/100IS-2 card UTP4-out octet counter |
| 1.3.6.1.4.1.4756.20.180.20.1.25 | Columnf100ISUtp3FnlRxByteLocal | read-only | current | Local FRM220-10/100IS-2 card UTP3-in final octets |
| 1.3.6.1.4.1.4756.20.180.20.1.26 | Columnf100ISUtp4FnlRxByteLocal | read-only | current | Local FRM220-10/100IS-2 card UTP4-in final octets |
| 1.3.6.1.4.1.4756.20.180.20.1.27 | Columnf100ISUtp3FnlTxByteLocal | read-only | current | Local FRM220-10/100IS-2 card UTP3-out final octets |
| 1.3.6.1.4.1.4756.20.180.20.1.28 | Columnf100ISUtp4FnlTxByteLocal | read-only | current | Local FRM220-10/100IS-2 card UTP4-out final octets |
| 1.3.6.1.4.1.4756.20.180.20.1.29 | Columnf100ISUtp3SpeedStatusLocal | read-only | current | Local FRM220-10/100IS-2 Utp3 Speed Status: 0:10MHz 1:100MHz |
| 1.3.6.1.4.1.4756.20.180.20.1.30 | Columnf100ISUtp4SpeedStatusLocal | read-only | current | Local FRM220-10/100IS-2 Utp4 Speed Status: 0:10MHz 1:100MHz |
| 1.3.6.1.4.1.4756.20.180.20.1.31 | Columnf100ISUtp3DuplexStatusLocal | read-only | current | Local FRM220-10/100IS-2 Utp3 Duplex Status: 0:Half 1:Full |
| 1.3.6.1.4.1.4756.20.180.20.1.32 | Columnf100ISUtp4DuplexStatusLocal | read-only | current | Local FRM220-10/100IS-2 Utp4 Duplex Status: 0:Half 1:Full |
| 1.3.6.1.4.1.4756.20.180.20.1.33 | Columnf100ISFx1LinkLocal | read-only | current | Local FRM220-10/100IS-2 card fiber1 link status: 0:Down 1:Up |
| 1.3.6.1.4.1.4756.20.180.20.1.34 | Columnf100ISFx2LinkLocal | read-only | current | Local FRM220-10/100IS-2 card fiber2 link status: 0:Down 1:Up |
| 1.3.6.1.4.1.4756.20.180.20.1.35 | Columnf100ISFx1RxActLocal | read-only | current | Local FRM220-10/100IS-2 card fiber1 receiver active status: 0:Off 1:On |
| 1.3.6.1.4.1.4756.20.180.20.1.36 | Columnf100ISFx2RxActLocal | read-only | current | Local FRM220-10/100IS-2 card fiber2 receiver active status: 0:Off 1:On |
| 1.3.6.1.4.1.4756.20.180.20.1.37 | Columnf100ISFx1FEFLocal | read-only | current | Local FRM220-10/100IS-2 card fiber1 detected Far End Fault: 0:Off 1:Detected |
| 1.3.6.1.4.1.4756.20.180.20.1.38 | Columnf100ISFx2FEFLocal | read-only | current | Local FRM220-10/100IS-2 card fiber2 detected Far End Fault: 0:Off 1:Detected |
| 1.3.6.1.4.1.4756.20.180.20.1.39 | Columnf100ISFx1LBTestLocal | read-write | current | Force remote FRM220-10/100IS-2 card to do fiber1 LoopBack testing: 0:Off 1:Action |
| 1.3.6.1.4.1.4756.20.180.20.1.40 | Columnf100ISFx2LBTestLocal | read-write | current | Force remote FRM220-10/100IS-2 card to do fiber2 LoopBack testing: 0:Off 1:Action |
| 1.3.6.1.4.1.4756.20.180.20.1.41 | Columnf100ISFx1LBStatusLocal | read-only | current | Local FRM220-10/100IS-2 card fiber1 LoopBack testing status: 0:Off 1:Ok 2:Fail |
| 1.3.6.1.4.1.4756.20.180.20.1.42 | Columnf100ISFx2LBStatusLocal | read-only | current | Local FRM220-10/100IS-2 card fiber2 LoopBack testing status: 0:Off 1:Ok 2:Fail |
| 1.3.6.1.4.1.4756.20.180.20.1.43 | Columnf100ISFx1RemoPWRAbLocal | read-only | current | Local FRM220-10/100IS-2 card fiber1 Remote Power status: 0:Abnormal 1:OK |
| 1.3.6.1.4.1.4756.20.180.20.1.44 | Columnf100ISFx2RemoPWRAbLocal | read-only | current | Local FRM220-10/100IS-2 card fiber2 Remote Power status: 0:Abnormal 1:OK |
| 1.3.6.1.4.1.4756.20.180.20.1.45 | Columnf100ISFx1IrlModeLocal | read-write | current | Local FRM220-10/100IS-2 card Fx1 Ingress Rate Limit mode: 0:No limit 1:n x 32K 2:n x 512K |
| 1.3.6.1.4.1.4756.20.180.20.1.46 | Columnf100ISFx2IrlModeLocal | read-write | current | Local FRM220-10/100IS-2 card Fx2 Ingress Rate Limit mode: 0:No limit 1:n x 32K 2:n x 512K |
| 1.3.6.1.4.1.4756.20.180.20.1.47 | Columnf100ISFx1IrlMultLocal | read-write | current | Local FRM220-10/100IS-2 card Fx1 Ingress Rate Limit multiple: When the irlMode-L is n x 32K mode, the Fx1 irlMult-L should be the value between 0 to 255; When … |
| 1.3.6.1.4.1.4756.20.180.20.1.48 | Columnf100ISFx2IrlMultLocal | read-write | current | Local FRM220-10/100IS-2 card Fx2 Ingress Rate Limit multiple: When the irlMode-L is n x 32K mode, the Fx2 irlMult-L should be the value between 0 to 255; When … |
| 1.3.6.1.4.1.4756.20.180.20.1.49 | Columnf100ISFx1ErlModeLocal | read-write | current | Local FRM220-10/100IS-2 card Fx1 Egress Rate Limit mode: 0:No limit 1:n x 32K 2:n x 512K |
| 1.3.6.1.4.1.4756.20.180.20.1.50 | Columnf100ISFx2ErlModeLocal | read-write | current | Local FRM220-10/100IS-2 card Fx2 Egress Rate Limit mode: 0:No limit 1:n x 32K 2:n x 512K |
| 1.3.6.1.4.1.4756.20.180.20.1.51 | Columnf100ISFx1ErlMultLocal | read-write | current | Local FRM220-10/100IS-2 card Fx1 Egress Rate Limit multiple: When the erlMode-L is n x 32K mode, the Fx1 erlMult-L should be the value between 0 to 255; When t… |
| 1.3.6.1.4.1.4756.20.180.20.1.52 | Columnf100ISFx2ErlMultLocal | read-write | current | Local FRM220-10/100IS-2 card Fx2 Egress Rate Limit multiple: When the erlMode-L is n x 32K mode, the Fx2 erlMult-L should be the value between 0 to 255; When t… |
| 1.3.6.1.4.1.4756.20.180.20.1.53 | Columnf100ISFx1RxByteLocal | read-only | current | Local FRM220-10/100IS-2 card FX1-in octet counter |
| 1.3.6.1.4.1.4756.20.180.20.1.54 | Columnf100ISFx2RxByteLocal | read-only | current | Local FRM220-10/100IS-2 card FX2-in octet counter |
| 1.3.6.1.4.1.4756.20.180.20.1.55 | Columnf100ISFx1TxByteLocal | read-only | current | Local FRM220-10/100IS-2 card FX1-out octet counter |
| 1.3.6.1.4.1.4756.20.180.20.1.56 | Columnf100ISFx2TxByteLocal | read-only | current | Local FRM220-10/100IS-2 card FX2-out octet counter |
| 1.3.6.1.4.1.4756.20.180.20.1.57 | Columnf100ISFx1FnlRxByteLocal | read-only | current | Local FRM220-10/100IS-2 card FX1-in final octets |
| 1.3.6.1.4.1.4756.20.180.20.1.58 | Columnf100ISFx2FnlRxByteLocal | read-only | current | Local FRM220-10/100IS-2 card FX2-in final octets |
| 1.3.6.1.4.1.4756.20.180.20.1.59 | Columnf100ISFx1FnlTxByteLocal | read-only | current | Local FRM220-10/100IS-2 card FX1-out final octets |
| 1.3.6.1.4.1.4756.20.180.20.1.60 | Columnf100ISFx2FnlTxByteLocal | read-only | current | Local FRM220-10/100IS-2 card FX2-out final octets |
| 1.3.6.1.4.1.4756.20.180.20.1.61 | Columnf100ISPortResetLocal | read-write | current | Force local FRM220-10/100IS-2 card to Fx1 reset mode: 0:Off 1:Action |
| 1.3.6.1.4.1.4756.20.180.20.1.62 | Columnf100ISFx1OpModeLocal | read-write | current | Local FRM220-10/100IS-2 card Fx1 operation mode: 0:Switch mode 1:Converter mode |
| 1.3.6.1.4.1.4756.20.180.20.1.63 | Columnf100ISFx2OpModeLocal | read-write | current | Local FRM220-10/100IS-2 card Fx2 operation mode: 0:Switch mode 1:Converter mode |
| 1.3.6.1.4.1.4756.20.180.20.1.64 | Columnf100ISFx1LfpModeLocal | read-write | current | Local FRM220-10/100IS-2 card Fx1 Link Fault Pass-through mode: 0:Disable 1:Enable |
| 1.3.6.1.4.1.4756.20.180.20.1.65 | Columnf100ISFx2LfpModeLocal | read-write | current | Local FRM220-10/100IS-2 card Fx2 Link Fault Pass-through mode: 0:Disable 1:Enable |
| 1.3.6.1.4.1.4756.20.180.20.1.66 | Columnf100ISFx1AlsModeLocal | read-write | current | Local FRM220-10/100IS-2 card Fx1 Auto Laser Shutdown mode: 0:Disable 1:Enable |
| 1.3.6.1.4.1.4756.20.180.20.1.67 | Columnf100ISFx2AlsModeLocal | read-write | current | Local FRM220-10/100IS-2 card Fx2 Auto Laser Shutdown mode: 0:Disable 1:Enable |
| 1.3.6.1.4.1.4756.20.180.20.1.68 | Columnf100ISFx1SendFHRLocal | read-write | current | Local FRM220-10/100IS-2 card Fx1 send Fiber Hardware Reset to remote: 0:No action 1:Action |
| 1.3.6.1.4.1.4756.20.180.20.1.69 | Columnf100ISFx2SendFHRLocal | read-write | current | Local FRM220-10/100IS-2 card Fx2 send Fiber Hardware Reset to remote: 0:No action 1:Action |
| 1.3.6.1.4.1.4756.20.180.20.1.70 | Columnf100ISFx1DDLocal | read-only | current | Local FRM220-10/100IS-2 card fiber1 Digital Diagnostic function: 0:No 1:Yes |
| 1.3.6.1.4.1.4756.20.180.20.1.71 | Columnf100ISFx2DDLocal | read-only | current | Local FRM220-10/100IS-2 card fiber2 Digital Diagnostic function: 0:No 1:Yes |
| 1.3.6.1.4.1.4756.20.180.20.1.72 | Columnf100ISFx1DDVendorLocal | read-only | current | Local FRM220-10/100IS-2 card fiber1 D/D information: Vendor name |
| 1.3.6.1.4.1.4756.20.180.20.1.73 | Columnf100ISFx2DDVendorLocal | read-only | current | Local FRM220-10/100IS-2 card fiber2 D/D information: Vendor name |
| 1.3.6.1.4.1.4756.20.180.20.1.74 | Columnf100ISFx1DDPartNoLocal | read-only | current | Local FRM220-10/100IS-2 card fiber1 D/D information: Vendor part number |
| 1.3.6.1.4.1.4756.20.180.20.1.75 | Columnf100ISFx2DDPartNoLocal | read-only | current | Local FRM220-10/100IS-2 card fiber2 D/D information: Vendor part number |
| 1.3.6.1.4.1.4756.20.180.20.1.76 | Columnf100ISFx1DDFiberTypeLocal | read-only | current | Local FRM220-10/100IS-2 card fiber1 D/D information: Fiber Type |
| 1.3.6.1.4.1.4756.20.180.20.1.77 | Columnf100ISFx2DDFiberTypeLocal | read-only | current | Local FRM220-10/100IS-2 card fiber2 D/D information: Fiber Type |
| 1.3.6.1.4.1.4756.20.180.20.1.78 | Columnf100ISFx1DDWaveLenLocal | read-only | current | Local FRM220-10/100IS-2 card fiber1 D/D information: Wave length |
| 1.3.6.1.4.1.4756.20.180.20.1.79 | Columnf100ISFx2DDWaveLenLocal | read-only | current | Local FRM220-10/100IS-2 card fiber2 D/D information: Wave length |
| 1.3.6.1.4.1.4756.20.180.20.1.80 | Columnf100ISFx1DDWaveLen2Local | read-only | current | Local FRM220-10/100IS-2 card fiber1 D/D information: Wave length 2 |
| 1.3.6.1.4.1.4756.20.180.20.1.81 | Columnf100ISFx2DDWaveLen2Local | read-only | current | Local FRM220-10/100IS-2 card fiber2 D/D information: Wave length 2 |
| 1.3.6.1.4.1.4756.20.180.20.1.82 | Columnf100ISFx1DDLinkLenLocal | read-only | current | Local FRM220-10/100IS-2 card fiber1 D/D information: Link length |
| 1.3.6.1.4.1.4756.20.180.20.1.83 | Columnf100ISFx2DDLinkLenLocal | read-only | current | Local FRM220-10/100IS-2 card fiber2 D/D information: Link length |
| 1.3.6.1.4.1.4756.20.180.20.1.84 | Columnf100ISFx1DDLenUnitLocal | read-only | current | Local FRM220-10/100IS-2 card fiber1 D/D information: Length Unit |
| 1.3.6.1.4.1.4756.20.180.20.1.85 | Columnf100ISFx2DDLenUnitLocal | read-only | current | Local FRM220-10/100IS-2 card fiber2 D/D information: Length Unit |
| 1.3.6.1.4.1.4756.20.180.20.1.86 | Columnf100ISFx1DDStatusLocal | read-only | current | Local FRM220-10/100IS-2 card fiber1 D/D information: Status Support |
| 1.3.6.1.4.1.4756.20.180.20.1.87 | Columnf100ISFx2DDStatusLocal | read-only | current | Local FRM220-10/100IS-2 card fiber2 D/D information: Status Support |
| 1.3.6.1.4.1.4756.20.180.20.1.88 | Columnf100ISFx1DDRxSensLocal | read-only | current | Local FRM220-10/100IS-2 card fiber1 D/D information: Rx Sensitivity |
| 1.3.6.1.4.1.4756.20.180.20.1.89 | Columnf100ISFx2DDRxSensLocal | read-only | current | Local FRM220-10/100IS-2 card fiber2 D/D information: Rx Sensitivity |
| 1.3.6.1.4.1.4756.20.180.20.1.90 | Columnf100ISFx1DDTxPWRLocal | read-only | current | Local FRM220-10/100IS-2 card fiber1 D/D information: Tx power |
| 1.3.6.1.4.1.4756.20.180.20.1.91 | Columnf100ISFx2DDTxPWRLocal | read-only | current | Local FRM220-10/100IS-2 card fiber2 D/D information: Tx power |
| 1.3.6.1.4.1.4756.20.180.20.1.92 | Columnf100ISFx1DDRxPWRLocal | read-only | current | Local FRM220-10/100IS-2 card fiber1 D/D information: Rx power |
| 1.3.6.1.4.1.4756.20.180.20.1.93 | Columnf100ISFx2DDRxPWRLocal | read-only | current | Local FRM220-10/100IS-2 card fiber2 D/D information: Rx power |
| 1.3.6.1.4.1.4756.20.180.20.1.94 | Columnf100ISFx1DDTempLocal | read-only | current | Local FRM220-10/100IS-2 card fiber1 D/D information: Temperature in degree C |
| 1.3.6.1.4.1.4756.20.180.20.1.95 | Columnf100ISFx2DDTempLocal | read-only | current | Local FRM220-10/100IS-2 card fiber2 D/D information: Temperature in degree C |
| 1.3.6.1.4.1.4756.20.180.20.1.96 | Columnf100ISFx1DDPWRMarginLocal | read-only | current | Local FRM220-10/100IS-2 card fiber1 D/D information: Power margin |
| 1.3.6.1.4.1.4756.20.180.20.1.97 | Columnf100ISFx2DDPWRMarginLocal | read-only | current | Local FRM220-10/100IS-2 card fiber2 D/D information: Power margin |
| 1.3.6.1.4.1.4756.20.180.20.1.98 | Columnf100ISFx1DDPWRLossLocal | read-only | current | Local FRM220-10/100IS-2 card fiber1 D/D information: Power loss |
| 1.3.6.1.4.1.4756.20.180.20.1.99 | Columnf100ISFx2DDPWRLossLocal | read-only | current | Local FRM220-10/100IS-2 card fiber2 D/D information: Power loss |
| 1.3.6.1.4.1.4756.20.180.20.1.100 | Columnf100ISInfoR1SN1Local | read-only | current | Local FRM220-10/100IS-2 card INFORemoteOM S/N 1 information |
| 1.3.6.1.4.1.4756.20.180.20.1.101 | Columnf100ISInfoR1SN2Local | read-only | current | Local FRM220-10/100IS-2 card INFORemoteOM S/N 2 information |
| 1.3.6.1.4.1.4756.20.181 | Nodef100ISRemoteACards | |||
| 1.3.6.1.4.1.4756.20.181.20 | Tablef100ISRemoteATable | not-accessible | current | A list of local FRM220-10/100IS-2 card entries. The number of entries is f100IS-No-L. |
| 1.3.6.1.4.1.4756.20.181.20.1 | Rowf100ISRemoteAEntry | not-accessible | current | An entry containing management information applicable to a particular local FRM220-10/100IS-2 card. |
| 1.3.6.1.4.1.4756.20.181.20.1.1 | Columnf100ISChassisIndexRemoteA | read-only | current | A unique value for each local card. It is the chassis location number. |
| 1.3.6.1.4.1.4756.20.181.20.1.2 | Columnf100ISSlotIndexRemoteA | read-only | current | A unique value for each local card. It is the slot location number. |
| 1.3.6.1.4.1.4756.20.181.20.1.3 | Columnf100ISCardHWVerRemoteA | read-only | current | RemoteA FRM220-10/100I card hardware version x.xxx |
| 1.3.6.1.4.1.4756.20.181.20.1.4 | Columnf100ISCardFWVerRemoteA | read-only | current | RemoteA FRM220-10/100I card firmware version x.xxx |
| 1.3.6.1.4.1.4756.20.181.20.1.5 | Columnf100ISCardCPLDVerRemoteA | read-only | current | RemoteA FRM220-10/100I card CPLD version x.xxx |
| 1.3.6.1.4.1.4756.20.181.20.1.6 | Columnf100ISCardFPGAVerRemoteA | read-only | current | RemoteA FRM220-10/100I card FPGA version x.xxx |
| 1.3.6.1.4.1.4756.20.181.20.1.7 | Columnf100ISPortActiveRemoteA | read-only | current | RemoteA FRM220-10/100IS-2 card FX1 active: 0:Inactive 1:Active |
| 1.3.6.1.4.1.4756.20.181.20.1.8 | Columnf100ISInBandManagRemoteA | read-only | current | RemoteA FRM220-10/100IS-2 card manages remote: 0:Disable 1:Enable |
| 1.3.6.1.4.1.4756.20.181.20.1.9 | Columnf100ISUtpLinkRemoteA | read-only | current | RemoteA FRM220-10/100IS-2 card UTP3 link status: 0:Down 1:Up |
| 1.3.6.1.4.1.4756.20.181.20.1.10 | Columnf100ISUtpRxActRemoteA | read-only | current | RemoteA FRM220-10/100IS-2 card UTP3 receive active status: 0:Off 1:On |
| 1.3.6.1.4.1.4756.20.181.20.1.11 | Columnf100ISUtpNegoRemoteA | read-write | current | RemoteA FRM220-10/100IS-2 card UTP3 negotiation status: 0:Manual 1:Auto |
| 1.3.6.1.4.1.4756.20.181.20.1.12 | Columnf100ISUtpSpeedRemoteA | read-write | current | RemoteA FRM220-10/100IS-2 card UTP3 speed Setting: 0:10MHz 1:100MHz |
| 1.3.6.1.4.1.4756.20.181.20.1.13 | Columnf100ISUtpDuplexRemoteA | read-write | current | RemoteA FRM220-10/100IS-2 card UTP3 duplex Setting: 0:Half duplex mode 1:Full duplex mode |
| 1.3.6.1.4.1.4756.20.181.20.1.14 | Columnf100ISUtpSpeedStatusRemoteA | read-only | current | RemoteA FRM220-10/100IS-2 card UTP3 speed Status: 0:10MHz 1:100MHz |
| 1.3.6.1.4.1.4756.20.181.20.1.15 | Columnf100ISUtpDuplexStatusRemoteA | read-only | current | RemoteA FRM220-10/100IS-2 card UTP3 duplex Status: 0:Half duplex mode 1:Full duplex mode |
| 1.3.6.1.4.1.4756.20.181.20.1.16 | Columnf100ISUtpRxByteRemoteA | read-only | current | RemoteA FRM220-10/100IS-2 card UTP3-in octet counter |
| 1.3.6.1.4.1.4756.20.181.20.1.17 | Columnf100ISUtpTxByteRemoteA | read-only | current | RemoteA FRM220-10/100IS-2 card UTP3-out octet counter |
| 1.3.6.1.4.1.4756.20.181.20.1.18 | Columnf100ISUtpFnlRxByteRemoteA | read-only | current | RemoteA FRM220-10/100IS-2 card UTP3-in final octets |
| 1.3.6.1.4.1.4756.20.181.20.1.19 | Columnf100ISUtpFnlTxByteRemoteA | read-only | current | RemoteA FRM220-10/100IS-2 card UTP3-out final octets |
| 1.3.6.1.4.1.4756.20.181.20.1.20 | Columnf100ISFxLinkRemoteA | read-only | current | RemoteA FRM220-10/100IS-2 card fiber1 link status: 0:Down 1:Up |
| 1.3.6.1.4.1.4756.20.181.20.1.21 | Columnf100ISFxRxActRemoteA | read-only | current | RemoteA FRM220-10/100IS-2 card fiber1 receiver active status: 0:Off 1:On |
| 1.3.6.1.4.1.4756.20.181.20.1.22 | Columnf100ISFxFEFRemoteA | read-only | current | RemoteA FRM220-10/100IS-2 card fiber1 detected Far End Fault: 0:Off 1:Detected |
| 1.3.6.1.4.1.4756.20.181.20.1.23 | Columnf100ISFxLBTestRemoteA | read-write | current | Force remote FRM220-10/100IS-2 card to do fiber1 LoopBack testing: 0:Off 1:Action |
| 1.3.6.1.4.1.4756.20.181.20.1.24 | Columnf100ISFxLBStatusRemoteA | read-only | current | RemoteA FRM220-10/100IS-2 card fiber1 LoopBack testing status: 0:Off 1:Ok 2:Fail |
| 1.3.6.1.4.1.4756.20.181.20.1.25 | Columnf100ISRemoPWRAbRemoteA | read-only | current | RemoteA FRM220-10/100IS-2 card fiber1 RemoteA Power status: 0:Abnormal 1:OK |
| 1.3.6.1.4.1.4756.20.181.20.1.26 | Columnf100ISIrlModeRemoteA | read-write | current | RemoteA FRM220-10/100IS-2 card Ingress Rate Limit mode: 0:No limit 1:n x 32K 2:n x 512K |
| 1.3.6.1.4.1.4756.20.181.20.1.27 | Columnf100ISIrlMultRemoteA | read-write | current | RemoteA FRM220-10/100IS-2 card Ingress Rate Limit multiple: When the irlMode-L is n x 32K mode, the irlMult-L should be the value between 0 to 255; When the ir… |
| 1.3.6.1.4.1.4756.20.181.20.1.28 | Columnf100ISErlModeRemoteA | read-write | current | RemoteA FRM220-10/100IS-2 card Egress Rate Limit mode: 0:No limit 1:n x 32K 2:n x 512K |
| 1.3.6.1.4.1.4756.20.181.20.1.29 | Columnf100ISErlMultRemoteA | read-write | current | RemoteA FRM220-10/100IS-2 card Egress Rate Limit multiple: When the erlMode-L is n x 32K mode, the erlMult-L should be the value between 0 to 255; When the erl… |
| 1.3.6.1.4.1.4756.20.181.20.1.30 | Columnf100ISRxByteRemoteA | read-only | current | RemoteA FRM220-10/100IS-2 card FX1-in octet counter |
| 1.3.6.1.4.1.4756.20.181.20.1.31 | Columnf100ISTxByteRemoteA | read-only | current | RemoteA FRM220-10/100IS-2 card FX1-out octet counter |
| 1.3.6.1.4.1.4756.20.181.20.1.32 | Columnf100ISFnlRxByteRemoteA | read-only | current | RemoteA FRM220-10/100IS-2 card FX1-in final octets |
| 1.3.6.1.4.1.4756.20.181.20.1.33 | Columnf100ISFnlTxByteRemoteA | read-only | current | RemoteA FRM220-10/100IS-2 card FX1-out final octets |
| 1.3.6.1.4.1.4756.20.181.20.1.34 | Columnf100ISPortResetRemoteA | read-write | current | Force local FRM220-10/100IS-2 card to reset mode: 0:Off 1:Action |
| 1.3.6.1.4.1.4756.20.181.20.1.35 | Columnf100ISOpModeRemoteA | read-write | current | RemoteA FRM220-10/100IS-2 card operation mode: 0:Switch mode 1:Converter mode |
| 1.3.6.1.4.1.4756.20.181.20.1.36 | Columnf100ISLfpModeRemoteA | read-write | current | RemoteA FRM220-10/100IS-2 card Link Fault Pass-through mode: 0:Disable 1:Enable |
| 1.3.6.1.4.1.4756.20.181.20.1.37 | Columnf100ISAlsModeRemoteA | read-write | current | RemoteA FRM220-10/100IS-2 card Auto Laser Shutdown mode: 0:Disable 1:Enable |
| 1.3.6.1.4.1.4756.20.181.20.1.38 | Columnf100ISFhrModeRemoteA | read-write | current | RemoteA FRM220-10/100IS-2 card accept fiber hardware reset mode: 0:Disable 1:Enable |
| 1.3.6.1.4.1.4756.20.181.20.1.39 | Columnf100ISDDRemoteA | read-only | current | RemoteA FRM220-10/100IS-2 card fiber1 Digital Diagnostic function: 0:No 1:Yes |
| 1.3.6.1.4.1.4756.20.181.20.1.40 | Columnf100ISDDVendorRemoteA | read-only | current | RemoteA FRM220-10/100IS-2 card fiber1 D/D information: Vendor name |
| 1.3.6.1.4.1.4756.20.181.20.1.41 | Columnf100ISDDPartNoRemoteA | read-only | current | RemoteA FRM220-10/100IS-2 card fiber1 D/D information: Vendor part number |
| 1.3.6.1.4.1.4756.20.181.20.1.42 | Columnf100ISDDFiberTypeRemoteA | read-only | current | RemoteA FRM220-10/100IS-2 card fiber1 D/D information: Fiber Type |
| 1.3.6.1.4.1.4756.20.181.20.1.43 | Columnf100ISDDWaveLenRemoteA | read-only | current | RemoteA FRM220-10/100IS-2 card fiber1 D/D information: Wave length |
| 1.3.6.1.4.1.4756.20.181.20.1.44 | Columnf100ISDDWaveLen2RemoteA | read-only | current | RemoteA FRM220-10/100IS-2 card fiber1 D/D information: Wave length 2 |
| 1.3.6.1.4.1.4756.20.181.20.1.45 | Columnf100ISDDLinkLenRemoteA | read-only | current | RemoteA FRM220-10/100IS-2 card fiber1 D/D information: Link length |
| 1.3.6.1.4.1.4756.20.181.20.1.46 | Columnf100ISDDLenUnitRemoteA | read-only | current | RemoteA FRM220-10/100IS-2 card fiber1 D/D information: Length Unit |
| 1.3.6.1.4.1.4756.20.181.20.1.47 | Columnf100ISDDStatusRemoteA | read-only | current | RemoteA FRM220-10/100IS-2 card fiber1 D/D information: Status Support |
| 1.3.6.1.4.1.4756.20.181.20.1.48 | Columnf100ISDDRxSensRemoteA | read-only | current | RemoteA FRM220-10/100IS-2 card fiber1 D/D information: Rx Sensitivity |
| 1.3.6.1.4.1.4756.20.181.20.1.49 | Columnf100ISDDTxPWRRemoteA | read-only | current | RemoteA FRM220-10/100IS-2 card fiber1 D/D information: Tx power |
| 1.3.6.1.4.1.4756.20.181.20.1.50 | Columnf100ISDDRxPWRRemoteA | read-only | current | RemoteA FRM220-10/100IS-2 card fiber1 D/D information: Rx power |
| 1.3.6.1.4.1.4756.20.181.20.1.51 | Columnf100ISDDTempRemoteA | read-only | current | RemoteA FRM220-10/100IS-2 card fiber1 D/D information: Temperature in degree C |
| 1.3.6.1.4.1.4756.20.181.20.1.52 | Columnf100ISDDPWRMarginRemoteA | read-only | current | RemoteA FRM220-10/100IS-2 card fiber1 D/D information: Power margin |
| 1.3.6.1.4.1.4756.20.181.20.1.53 | Columnf100ISDDPWRLossRemoteA | read-only | current | RemoteA FRM220-10/100IS-2 card fiber1 D/D information: Power loss |
| 1.3.6.1.4.1.4756.20.181.20.1.54 | Columnf100ISInfoR1SN1RemoteA | read-only | current | RemoteA FRM220-10/100IS-2 card INFOROM S/N 1 information |
| 1.3.6.1.4.1.4756.20.181.20.1.55 | Columnf100ISInfoR1SN2RemoteA | read-only | current | RemoteA FRM220-10/100IS-2 card INFOROM S/N 2 information |
| 1.3.6.1.4.1.4756.20.182 | Nodef100ISRemoteBCards | |||
| 1.3.6.1.4.1.4756.20.182.20 | Tablef100ISRemoteBTable | not-accessible | current | A list of local FRM220-10/100IS-2 card entries. The number of entries is f100IS-No-L. |
| 1.3.6.1.4.1.4756.20.182.20.1 | Rowf100ISRemoteBEntry | not-accessible | current | An entry containing management information applicable to a particular local FRM220-10/100IS-2 card. |
| 1.3.6.1.4.1.4756.20.182.20.1.1 | Columnf100ISChassisIndexRemoteB | read-only | current | A unique value for each local card. It is the chassis location number. |
| 1.3.6.1.4.1.4756.20.182.20.1.2 | Columnf100ISSlotIndexRemoteB | read-only | current | A unique value for each local card. It is the slot location number. |
| 1.3.6.1.4.1.4756.20.182.20.1.3 | Columnf100ISCardHWVerRemoteB | read-only | current | RemoteB FRM220-10/100I card hardware version x.xxx |
| 1.3.6.1.4.1.4756.20.182.20.1.4 | Columnf100ISCardFWVerRemoteB | read-only | current | RemoteB FRM220-10/100I card firmware version x.xxx |
| 1.3.6.1.4.1.4756.20.182.20.1.5 | Columnf100ISCardCPLDVerRemoteB | read-only | current | RemoteB FRM220-10/100I card CPLD version x.xxx |
| 1.3.6.1.4.1.4756.20.182.20.1.6 | Columnf100ISCardFPGAVerRemoteB | read-only | current | RemoteB FRM220-10/100I card FPGA version x.xxx |
| 1.3.6.1.4.1.4756.20.182.20.1.7 | Columnf100ISPortActiveRemoteB | read-only | current | RemoteB FRM220-10/100IS-2 card FX1 active: 0:Inactive 1:Active |
| 1.3.6.1.4.1.4756.20.182.20.1.8 | Columnf100ISInBandManagRemoteB | read-only | current | RemoteB FRM220-10/100IS-2 card manages remote: 0:Disable 1:Enable |
| 1.3.6.1.4.1.4756.20.182.20.1.9 | Columnf100ISUtpLinkRemoteB | read-only | current | RemoteB FRM220-10/100IS-2 card UTP3 link status: 0:Down 1:Up |
| 1.3.6.1.4.1.4756.20.182.20.1.10 | Columnf100ISUtpRxActRemoteB | read-only | current | RemoteB FRM220-10/100IS-2 card UTP3 receive active status: 0:Off 1:On |
| 1.3.6.1.4.1.4756.20.182.20.1.11 | Columnf100ISUtpNegoRemoteB | read-write | current | RemoteB FRM220-10/100IS-2 card UTP3 negotiation status: 0:Manual 1:Auto |
| 1.3.6.1.4.1.4756.20.182.20.1.12 | Columnf100ISUtpSpeedRemoteB | read-write | current | RemoteB FRM220-10/100IS-2 card UTP3 speed : 0:10MHz 1:100MHz |
| 1.3.6.1.4.1.4756.20.182.20.1.13 | Columnf100ISUtpDuplexRemoteB | read-write | current | RemoteB FRM220-10/100IS-2 card UTP3 duplex Setting: 0:Half duplex mode 1:Full duplex mode |
| 1.3.6.1.4.1.4756.20.182.20.1.14 | Columnf100ISUtpSpeedStatusRemoteB | read-only | current | RemoteB FRM220-10/100IS-2 card UTP3 speed Status: 0:10MHz 1:100MHz |
| 1.3.6.1.4.1.4756.20.182.20.1.15 | Columnf100ISUtpDuplexStatusRemoteB | read-only | current | RemoteB FRM220-10/100IS-2 card UTP3 duplex Status: 0:Half duplex mode 1:Full duplex mode |
| 1.3.6.1.4.1.4756.20.182.20.1.16 | Columnf100ISUtpRxByteRemoteB | read-only | current | RemoteB FRM220-10/100IS-2 card UTP3-in octet Setting |
| 1.3.6.1.4.1.4756.20.182.20.1.17 | Columnf100ISUtpTxByteRemoteB | read-only | current | RemoteB FRM220-10/100IS-2 card UTP3-out octet counter |
| 1.3.6.1.4.1.4756.20.182.20.1.18 | Columnf100ISUtpFnlRxByteRemoteB | read-only | current | RemoteB FRM220-10/100IS-2 card UTP3-in final octets |
| 1.3.6.1.4.1.4756.20.182.20.1.19 | Columnf100ISUtpFnlTxByteRemoteB | read-only | current | RemoteB FRM220-10/100IS-2 card UTP3-out final octets |
| 1.3.6.1.4.1.4756.20.182.20.1.20 | Columnf100ISFxLinkRemoteB | read-only | current | RemoteB FRM220-10/100IS-2 card fiber1 link status: 0:Down 1:Up |
| 1.3.6.1.4.1.4756.20.182.20.1.21 | Columnf100ISFxRxActRemoteB | read-only | current | RemoteB FRM220-10/100IS-2 card fiber1 receiver active status: 0:Off 1:On |
| 1.3.6.1.4.1.4756.20.182.20.1.22 | Columnf100ISFxFEFRemoteB | read-only | current | RemoteB FRM220-10/100IS-2 card fiber1 detected Far End Fault: 0:Off 1:Detected |
| 1.3.6.1.4.1.4756.20.182.20.1.23 | Columnf100ISFxLBTestRemoteB | read-write | current | Force remote FRM220-10/100IS-2 card to do fiber1 LoopBack testing: 0:Off 1:Action |
| 1.3.6.1.4.1.4756.20.182.20.1.24 | Columnf100ISFxLBStatusRemoteB | read-only | current | RemoteB FRM220-10/100IS-2 card fiber1 LoopBack testing status: 0:Off 1:Ok 2:Fail |
| 1.3.6.1.4.1.4756.20.182.20.1.25 | Columnf100ISRemoPWRAbRemoteB | read-only | current | RemoteB FRM220-10/100IS-2 card fiber1 RemoteB Power status: 0:Abnormal 1:OK |
| 1.3.6.1.4.1.4756.20.182.20.1.26 | Columnf100ISIrlModeRemoteB | read-write | current | RemoteB FRM220-10/100IS-2 card Ingress Rate Limit mode: 0:No limit 1:n x 32K 2:n x 512K |
| 1.3.6.1.4.1.4756.20.182.20.1.27 | Columnf100ISIrlMultRemoteB | read-write | current | RemoteB FRM220-10/100IS-2 card Ingress Rate Limit multiple: When the irlMode-L is n x 32K mode, the irlMult-L should be the value between 0 to 255; When the ir… |
| 1.3.6.1.4.1.4756.20.182.20.1.28 | Columnf100ISErlModeRemoteB | read-write | current | RemoteB FRM220-10/100IS-2 card Egress Rate Limit mode: 0:No limit 1:n x 32K 2:n x 512K |
| 1.3.6.1.4.1.4756.20.182.20.1.29 | Columnf100ISErlMultRemoteB | read-write | current | RemoteB FRM220-10/100IS-2 card Egress Rate Limit multiple: When the erlMode-L is n x 32K mode, the erlMult-L should be the value between 0 to 255; When the erl… |
| 1.3.6.1.4.1.4756.20.182.20.1.30 | Columnf100ISRxByteRemoteB | read-only | current | RemoteB FRM220-10/100IS-2 card FX1-in octet counter |
| 1.3.6.1.4.1.4756.20.182.20.1.31 | Columnf100ISTxByteRemoteB | read-only | current | RemoteB FRM220-10/100IS-2 card FX1-out octet counter |
| 1.3.6.1.4.1.4756.20.182.20.1.32 | Columnf100ISFnlRxByteRemoteB | read-only | current | RemoteB FRM220-10/100IS-2 card FX1-in final octets |
| 1.3.6.1.4.1.4756.20.182.20.1.33 | Columnf100ISFnlTxByteRemoteB | read-only | current | RemoteB FRM220-10/100IS-2 card FX1-out final octets |
| 1.3.6.1.4.1.4756.20.182.20.1.34 | Columnf100ISPortResetRemoteB | read-write | current | Force local FRM220-10/100IS-2 card to reset mode: 0:Off 1:Action |
| 1.3.6.1.4.1.4756.20.182.20.1.35 | Columnf100ISOpModeRemoteB | read-write | current | RemoteB FRM220-10/100IS-2 card operation mode: 0:Switch mode 1:Converter mode |
| 1.3.6.1.4.1.4756.20.182.20.1.36 | Columnf100ISLfpModeRemoteB | read-write | current | RemoteB FRM220-10/100IS-2 card Link Fault Pass-through mode: 0:Disable 1:Enable |
| 1.3.6.1.4.1.4756.20.182.20.1.37 | Columnf100ISAlsModeRemoteB | read-write | current | RemoteB FRM220-10/100IS-2 card Auto Laser Shutdown mode: 0:Disable 1:Enable |
| 1.3.6.1.4.1.4756.20.182.20.1.38 | Columnf100ISFhrModeRemoteB | read-write | current | RemoteB FRM220-10/100IS-2 card accept Fiber Hardware Reset mode: 0:Disable 1:Enable |
| 1.3.6.1.4.1.4756.20.182.20.1.39 | Columnf100ISDDRemoteB | read-only | current | RemoteB FRM220-10/100IS-2 card fiber1 Digital Diagnostic function: 0:No 1:Yes |
| 1.3.6.1.4.1.4756.20.182.20.1.40 | Columnf100ISDDVendorRemoteB | read-only | current | RemoteB FRM220-10/100IS-2 card fiber1 D/D information: Vendor name |
| 1.3.6.1.4.1.4756.20.182.20.1.41 | Columnf100ISDDPartNoRemoteB | read-only | current | RemoteB FRM220-10/100IS-2 card fiber1 D/D information: Vendor part number |
| 1.3.6.1.4.1.4756.20.182.20.1.42 | Columnf100ISDDFiberTypeRemoteB | read-only | current | RemoteB FRM220-10/100IS-2 card fiber1 D/D information: Fiber Type |
| 1.3.6.1.4.1.4756.20.182.20.1.43 | Columnf100ISDDWaveLenRemoteB | read-only | current | RemoteB FRM220-10/100IS-2 card fiber1 D/D information: Wave length |
| 1.3.6.1.4.1.4756.20.182.20.1.44 | Columnf100ISDDWaveLen2RemoteB | read-only | current | RemoteB FRM220-10/100IS-2 card fiber1 D/D information: Wave length 2 |
| 1.3.6.1.4.1.4756.20.182.20.1.45 | Columnf100ISDDLinkLenRemoteB | read-only | current | RemoteB FRM220-10/100IS-2 card fiber1 D/D information: Link length |
| 1.3.6.1.4.1.4756.20.182.20.1.46 | Columnf100ISDDLenUnitRemoteB | read-only | current | RemoteB FRM220-10/100IS-2 card fiber1 D/D information: Length Unit |
| 1.3.6.1.4.1.4756.20.182.20.1.47 | Columnf100ISDDStatusRemoteB | read-only | current | RemoteB FRM220-10/100IS-2 card fiber1 D/D information: Status Support |
| 1.3.6.1.4.1.4756.20.182.20.1.48 | Columnf100ISDDRxSensRemoteB | read-only | current | RemoteB FRM220-10/100IS-2 card fiber1 D/D information: Rx Sensitivity |
| 1.3.6.1.4.1.4756.20.182.20.1.49 | Columnf100ISDDTxPWRRemoteB | read-only | current | RemoteB FRM220-10/100IS-2 card fiber1 D/D information: Tx power |
| 1.3.6.1.4.1.4756.20.182.20.1.50 | Columnf100ISDDRxPWRRemoteB | read-only | current | RemoteB FRM220-10/100IS-2 card fiber1 D/D information: Rx power |
| 1.3.6.1.4.1.4756.20.182.20.1.51 | Columnf100ISDDTempRemoteB | read-only | current | RemoteB FRM220-10/100IS-2 card fiber1 D/D information: Temperature in degree C |
| 1.3.6.1.4.1.4756.20.182.20.1.52 | Columnf100ISDDPWRMarginRemoteB | read-only | current | RemoteB FRM220-10/100IS-2 card fiber1 D/D information: Power margin |
| 1.3.6.1.4.1.4756.20.182.20.1.53 | Columnf100ISDDPWRLossRemoteB | read-only | current | RemoteB FRM220-10/100IS-2 card fiber1 D/D information: Power loss |
| 1.3.6.1.4.1.4756.20.182.20.1.54 | Columnf100ISInfoR1SN1RemoteB | read-only | current | RemoteB FRM220-10/100IS-2 card INFORemoteBOM S/N 1 information |
| 1.3.6.1.4.1.4756.20.182.20.1.55 | Columnf100ISInfoR1SN2RemoteB | read-only | current | RemoteB FRM220-10/100IS-2 card INFORemoteBOM S/N 2 information |
| 1.3.6.1.4.1.4756.20.190 | Nodef100ASLocalCards | |||
| 1.3.6.1.4.1.4756.20.190.40 | Tablef100ASLocalTable | not-accessible | current | A list of local frm220-100AS card entries. The number of entries is f100AS-NoLocal. |
| 1.3.6.1.4.1.4756.20.190.40.1 | Rowf100ASLocalEntry | not-accessible | current | An entry containing management information applicable to a particular local FRM-100AS card. |
| 1.3.6.1.4.1.4756.20.190.40.1.1 | Columnf100ASChassisIndexLocal | read-only | current | A unique value for each local card. It is the chassis location number. |
| 1.3.6.1.4.1.4756.20.190.40.1.2 | Columnf100ASSlotIndexLocal | read-only | current | A unique value for each local card. It is the slot location number. |
| 1.3.6.1.4.1.4756.20.190.40.1.3 | Columnf100ASCardHWVerLocal | read-only | current | Local device card hardware version x.xxx |
| 1.3.6.1.4.1.4756.20.190.40.1.4 | Columnf100ASCardFWVerLocal | read-only | current | Local device card firmware version x.xxx |
| 1.3.6.1.4.1.4756.20.190.40.1.5 | Columnf100ASCardCPLDVerLocal | read-only | current | Local device card CPLD version x.xxx |
| 1.3.6.1.4.1.4756.20.190.40.1.6 | Columnf100ASCardFPGAVerLocal | read-only | current | Local device card FPGA version x.xxx |
| 1.3.6.1.4.1.4756.20.190.40.1.7 | Columnf100ASModelLocal | read-only | current | Local frm220 f100AS Serial Type |
| 1.3.6.1.4.1.4756.20.190.40.1.8 | Columnf100ASFx1LinkLocal | read-only | current | Local device card fiber port 1 link status: 0:Down 1:Up |
| 1.3.6.1.4.1.4756.20.190.40.1.9 | Columnf100ASFx1OAMLoopedLocal | read-only | current | Local device card fiber port 1 OAM looped: 0:Off 1:on |
| 1.3.6.1.4.1.4756.20.190.40.1.10 | Columnf100ASFx1LBTestLocal | read-write | current | Force remote device card to do fiber port 1 LoopBack testing: 0:Off 1:Action |
| 1.3.6.1.4.1.4756.20.190.40.1.11 | Columnf100ASFx1OAMRLBStatusLocal | read-only | current | Remote device card fiber port 1 LoopBack testing status: 0:Off 1:Ok 2:Fail |
| 1.3.6.1.4.1.4756.20.190.40.1.12 | Columnf100ASFx1RemoPwrAbLocal | read-only | current | Local device card fiber port 1 Remote Power status: 0:Abnormal 1:OK 2:None |
| 1.3.6.1.4.1.4756.20.190.40.1.13 | Columnf100ASFx2LinkLocal | read-only | current | Local device card fiber port 2 link status: 0:Down 1:Up |
| 1.3.6.1.4.1.4756.20.190.40.1.14 | Columnf100ASFx2OAMLoopedLocal | read-only | current | Local device card fiber port 2 OAM looped: 0:Off 1:on |
| 1.3.6.1.4.1.4756.20.190.40.1.15 | Columnf100ASFx2LBTestLocal | read-write | current | Force remote device card to do fiber port 2 LoopBack testing: 0:Off 1:Action |
| 1.3.6.1.4.1.4756.20.190.40.1.16 | Columnf100ASFx2OAMRLBStatusLocal | read-only | current | Remote device card fiber port 1 LoopBack testing status: 0:Off 1:Ok 2:Fail |
| 1.3.6.1.4.1.4756.20.190.40.1.17 | Columnf100ASFx2RemoPwrAbLocal | read-only | current | Local device card fiber port 2 Remote Power status: 0:Abnormal 1:OK 2:None |
| 1.3.6.1.4.1.4756.20.190.40.1.18 | Columnf100ASUtp1LinkLocal | read-only | current | Local device card UTP port 3 link status: 0:Down 1:Up |
| 1.3.6.1.4.1.4756.20.190.40.1.19 | Columnf100ASUtp1NegoLocal | read-write | current | Local device card UTP port 3 negotiation status: 0:Manual 1:Auto |
| 1.3.6.1.4.1.4756.20.190.40.1.20 | Columnf100ASUtp1SpeedLocal | read-write | current | Local device card UTP port 3 speed setting: 0:10 Base-T 1:100 Base-TX |
| 1.3.6.1.4.1.4756.20.190.40.1.21 | Columnf100ASUtp1DuplexLocal | read-write | current | Local device card UTP port 3 duplex setting: 0:Half duplex mode 1:Full duplex mode |
| 1.3.6.1.4.1.4756.20.190.40.1.22 | Columnf100ASUtp1SpeedStatusLocal | read-only | current | Local device card UTP port 3 speed status: 0:10 Base-T 1:100 Base-TX |
| 1.3.6.1.4.1.4756.20.190.40.1.23 | Columnf100ASUtp1DuplexStatusLocal | read-only | current | Local device card UTP port 3 duplex status: 0:Half duplex mode 1:Full duplex mode |
| 1.3.6.1.4.1.4756.20.190.40.1.24 | Columnf100ASUtp2LinkLocal | read-only | current | Local device card UTP port 4 link status: 0:Down 1:Up |
| 1.3.6.1.4.1.4756.20.190.40.1.25 | Columnf100ASUtp2NegoLocal | read-write | current | Local device card UTP port 4 negotiation status: 0:Manual 1:Auto |
| 1.3.6.1.4.1.4756.20.190.40.1.26 | Columnf100ASUtp2SpeedLocal | read-write | current | Local device card UTP port 4 speed setting: 0:10 Base-T 1:100 Base-TX |
| 1.3.6.1.4.1.4756.20.190.40.1.27 | Columnf100ASUtp2DuplexLocal | read-write | current | Local device card UTP port 4 duplex setting: 0:Half duplex mode 1:Full duplex mode |
| 1.3.6.1.4.1.4756.20.190.40.1.28 | Columnf100ASUtp2SpeedStatusLocal | read-only | current | Local device card UTP port 4 speed status: 0:10 Base-T 1:100 Base-TX |
| 1.3.6.1.4.1.4756.20.190.40.1.29 | Columnf100ASUtp2DuplexStatusLocal | read-only | current | Local device card UTP port 4 duplex status: 0:Half duplex mode 1:Full duplex mode |
| 1.3.6.1.4.1.4756.20.190.40.1.30 | Columnf100ASFx1IrlModeLocal | read-write | current | Local device card port 1 Rate Limit mode: 0:unlimited 1:limited |
| 1.3.6.1.4.1.4756.20.190.40.1.31 | Columnf100ASFx1IrlIndexLocal | read-write | current | Local device card port 1 Ingress Rate Limit index: Index Limit Rate 0 Unlimited 1 128K 2 256K 3 521K 4 1M 5 2M 6 4M 7 8M |
| 1.3.6.1.4.1.4756.20.190.40.1.32 | Columnf100ASFx1ErlIndexLocal | read-write | current | Local device card port 1 Egress Rate Limit index: Index Limit Rate 0 Unlimited 1 128K 2 256K 3 521K 4 1M 5 2M 6 4M 7 8M |
| 1.3.6.1.4.1.4756.20.190.40.1.33 | Columnf100ASFx2IrlModeLocal | read-write | current | Local device card port 2 Rate Limit mode: 0:unlimited 1:limited |
| 1.3.6.1.4.1.4756.20.190.40.1.34 | Columnf100ASFx2IrlIndexLocal | read-write | current | Local device card port 2 Ingress Rate Limit index: Index Limit Rate 0 Unlimited 1 128K 2 256K 3 521K 4 1M 5 2M 6 4M 7 8M |
| 1.3.6.1.4.1.4756.20.190.40.1.35 | Columnf100ASFx2ErlIndexLocal | read-write | current | Local device card port 2 Egress Rate Limit index: Index Limit Rate 0 Unlimited 1 128K 2 256K 3 521K 4 1M 5 2M 6 4M 7 8M |
| 1.3.6.1.4.1.4756.20.190.40.1.36 | Columnf100ASUtp1IrlModeLocal | read-write | current | Local device card port 3 Rate Limit mode: 0:unlimited 1:limited |
| 1.3.6.1.4.1.4756.20.190.40.1.37 | Columnf100ASUtp1IrlIndexLocal | read-write | current | Local device card port 3 Ingress Rate Limit index: Index Limit Rate 0 Unlimited 1 128K 2 256K 3 521K 4 1M 5 2M 6 4M 7 8M |
| 1.3.6.1.4.1.4756.20.190.40.1.38 | Columnf100ASUtp1ErlIndexLocal | read-write | current | Local device card port 3 Egress Rate Limit index: Index Limit Rate 0 Unlimited 1 128K 2 256K 3 521K 4 1M 5 2M 6 4M 7 8M |
| 1.3.6.1.4.1.4756.20.190.40.1.39 | Columnf100ASUtp2IrlModeLocal | read-write | current | Local device card port 4 Rate Limit mode: 0:unlimited 1:limited |
| 1.3.6.1.4.1.4756.20.190.40.1.40 | Columnf100ASUtp2IrlIndexLocal | read-write | current | Local device card port 4 Ingress Rate Limit index: Index Limit Rate 0 Unlimited 1 128K 2 256K 3 521K 4 1M 5 2M 6 4M 7 8M |
| 1.3.6.1.4.1.4756.20.190.40.1.41 | Columnf100ASUtp2ErlIndexLocal | read-write | current | Local device card port 4 Egress Rate Limit index: Index Limit Rate 0 Unlimited 1 128K 2 256K 3 521K 4 1M 5 2M 6 4M 7 8M |
| 1.3.6.1.4.1.4756.20.190.40.1.42 | Columnf100ASDeviceActiveLocal | read-write | current | Local device card active mode: (It is read-only in local device.) 0:Disable 1:Enable |
| 1.3.6.1.4.1.4756.20.190.40.1.43 | Columnf100ASDeviceResetLocal | read-write | current | Force local device card to reset mode: 0:Off 1:Action |
| 1.3.6.1.4.1.4756.20.190.40.1.44 | Columnf100ASFx1ActiveLocal | read-write | current | Local device fiber port 1 active mode: 0:Disable 1:Enable |
| 1.3.6.1.4.1.4756.20.190.40.1.45 | Columnf100ASFx2ActiveLocal | read-write | current | Local device fiber port 2 active mode: 0:Disable 1:Enable |
| 1.3.6.1.4.1.4756.20.190.40.1.46 | Columnf100ASUtp1ActiveLocal | read-write | current | Local device UTP port 3 active mode: 0:Disable 1:Enable |
| 1.3.6.1.4.1.4756.20.190.40.1.47 | Columnf100ASUtp2ActiveLocal | read-write | current | Local device UTP port 4 active mode: 0:Disable 1:Enable |
| 1.3.6.1.4.1.4756.20.190.40.1.48 | Columnf100ASOamChAModeLocal | read-write | current | Local device OAM Channel A mode: 0:Disable 1:passive 2:Active |
| 1.3.6.1.4.1.4756.20.190.40.1.49 | Columnf100ASOamChBModeLocal | read-write | current | Local device OAM Channel B mode: 0:Disable 1:passive 2:Active |
| 1.3.6.1.4.1.4756.20.190.40.1.50 | Columnf100ASOamMaxPDUsLocal | read-write | current | Local device OAM max OAMPDU size: 60-1518 Octets |
| 1.3.6.1.4.1.4756.20.190.40.1.51 | Columnf100ASFx1AlsLocal | read-write | current | Local device card port 1 Auto Laser Shutdown mode: 0:Disable 1:Enable |
| 1.3.6.1.4.1.4756.20.190.40.1.52 | Columnf100ASFx2AlsLocal | read-write | current | Local device card port 2 Auto Laser Shutdown mode: 0:Disable 1:Enable |
| 1.3.6.1.4.1.4756.20.190.40.1.53 | Columnf100ASPauseFrameLocal | read-write | current | Local device card pause frame mode: 0:Disable 1:Enable |
| 1.3.6.1.4.1.4756.20.190.40.1.54 | Columnf100ASSendFHRtoALocal | read-write | current | Local device card port 1 send Fiber Hardware Reset to remote: 0:No action 1:Action |
| 1.3.6.1.4.1.4756.20.190.40.1.55 | Columnf100ASSendFHRtoBLocal | read-write | current | Local device card port 2 send Fiber Hardware Reset to remote: 0:No action 1:Action |
| 1.3.6.1.4.1.4756.20.190.40.1.56 | Columnf100ASFx1LLFDepLogiLocal | read-write | current | Local device card port 1 Link Loss Forwarding depends boolean logic: 0:and 1:or |
| 1.3.6.1.4.1.4756.20.190.40.1.57 | Columnf100ASFx1LLFDepPort2Local | read-write | current | Local device card port 1 Link Loss Forwarding depends on port 2 Fiber Rx link: 0:don't care 1:selected |
| 1.3.6.1.4.1.4756.20.190.40.1.58 | Columnf100ASFx1LLFDepPort3Local | read-write | current | Local device card port 1 Link Loss Forwarding depends on port 3 Ethernet Rx link: 0:don't care 1:selected |
| 1.3.6.1.4.1.4756.20.190.40.1.59 | Columnf100ASFx1LLFDepPort4Local | read-write | current | Local device card port 1 Link Loss Forwarding depends on port 4 Ethernet Rx link: 0:don't care 1:selected |
| 1.3.6.1.4.1.4756.20.190.40.1.60 | Columnf100ASFx2LLFDepLogiLocal | read-write | current | Local device card port 2 Link Loss Forwarding depends boolean logic: 0:and 1:or |
| 1.3.6.1.4.1.4756.20.190.40.1.61 | Columnf100ASFx2LLFDepPort1Local | read-write | current | Local device card port 2 Link Loss Forwarding depends on port 1 Fiber Rx link: 0:don't care 1:selected |
| 1.3.6.1.4.1.4756.20.190.40.1.62 | Columnf100ASFx2LLFDepPort3Local | read-write | current | Local device card port 2 Link Loss Forwarding depends on port 3 Ethernet Rx link: 0:don't care 1:selected |
| 1.3.6.1.4.1.4756.20.190.40.1.63 | Columnf100ASFx2LLFDepPort4Local | read-write | current | Local device card port 2 Link Loss Forwarding depends on port 4 Ethernet Rx link: 0:don't care 1:selected |
| 1.3.6.1.4.1.4756.20.190.40.1.64 | Columnf100ASUtp1LLFDepLogiLocal | read-write | current | Local device card port 3 Link Loss Forwarding depends boolean logic: 0:and 1:or |
| 1.3.6.1.4.1.4756.20.190.40.1.65 | Columnf100ASUtp1LLFDepPort1Local | read-write | current | Local device card port 3 Link Loss Forwarding depends on port 1 Fiber Rx link: 0:don't care 1:selected |
| 1.3.6.1.4.1.4756.20.190.40.1.66 | Columnf100ASUtp1LLFDepPort2Local | read-write | current | Local device card port 3 Link Loss Forwarding depends on port 2 Fiber Rx link: 0:don't care 1:selected |
| 1.3.6.1.4.1.4756.20.190.40.1.67 | Columnf100ASUtp2LLFDepLogiLocal | read-write | current | Local device card port 4 Link Loss Forwarding depends boolean logic: 0:and 1:or |
| 1.3.6.1.4.1.4756.20.190.40.1.68 | Columnf100ASUtp2LLFDepPort1Local | read-write | current | Local device card port 4 Link Loss Forwarding depends on port 1 Fiber Rx link: 0:don't care 1:selected |
| 1.3.6.1.4.1.4756.20.190.40.1.69 | Columnf100ASUtp2LLFDepPort2Local | read-write | current | Local device card port 4 Link Loss Forwarding depends on port 2 Fiber Rx link: 0:don't care 1:selected |
| 1.3.6.1.4.1.4756.20.190.40.1.70 | Columnf100ASAdvanceFunsLocal | read-write | current | Local device card Switch functions mode: 0:Normal 2:Port 1&2 Mirror 3:Port VLAN 1/3;2/4 4:Port 1&2 Redundancy 5:Static 802.1Q VLAN 6:Spanning Tree protocol 7:S… |
| 1.3.6.1.4.1.4756.20.190.40.1.71 | Columnf100ASFx1InfoROM1Local | read-only | current | Local device card port 1 INFORemoteOM information 1 valid: 0:Invalid 1:Valid |
| 1.3.6.1.4.1.4756.20.190.40.1.72 | Columnf100ASFx1InfoROM2Local | read-only | current | Local device card port 1 INFORemoteOM information 2 valid: 0:Invalid 1:Valid(replacing D/D function |
| 1.3.6.1.4.1.4756.20.190.40.1.73 | Columnf100ASFx2InfoROM1Local | read-only | current | Local device card port 2 INFORemoteOM information 1 valid: 0:Invalid 1:Valid |
| 1.3.6.1.4.1.4756.20.190.40.1.74 | Columnf100ASFx2InfoROM2Local | read-only | current | Local device card port 2 INFORemoteOM information 2 valid: 0:Invalid 1:Valid(replacing D/D function) |
| 1.3.6.1.4.1.4756.20.190.40.1.75 | Columnf100ASFx1InfoSN1Local | read-only | current | Local device card port 1 INFORemoteOM S/N 1 |
| 1.3.6.1.4.1.4756.20.190.40.1.76 | Columnf100ASFx1InfoSN2Local | read-only | current | Local device card port 1 INFORemoteOM S/N 2 |
| 1.3.6.1.4.1.4756.20.190.40.1.77 | Columnf100ASFx2InfoSN1Local | read-only | current | Local device card port 2 INFORemoteOM S/N 1 |
| 1.3.6.1.4.1.4756.20.190.40.1.78 | Columnf100ASFx2InfoSN2Local | read-only | current | Local device card port 2 INFORemoteOM S/N 2 |
| 1.3.6.1.4.1.4756.20.190.40.1.79 | Columnf100ASFx1DDLocal | read-only | current | Local device card fiber port 1 Digital Diagnostic function: 0:No 1:Yes |
| 1.3.6.1.4.1.4756.20.190.40.1.80 | Columnf100ASFx1DDVendorLocal | read-only | current | Local device card fiber port 1 D/D information: Vendor name |
| 1.3.6.1.4.1.4756.20.190.40.1.81 | Columnf100ASFx1DDPartNoLocal | read-only | current | Local device card fiber port 1 D/D information: Vendor part number |
| 1.3.6.1.4.1.4756.20.190.40.1.82 | Columnf100ASFx1DDFiberTypeLocal | read-only | current | Local device card fiber port 1 D/D information: Fiber Type |
| 1.3.6.1.4.1.4756.20.190.40.1.83 | Columnf100ASFx1DDWaveLenLocal | read-only | current | Local device card fiber port 1 D/D information: Wave length |
| 1.3.6.1.4.1.4756.20.190.40.1.84 | Columnf100ASFx1DDWaveLen2Local | read-only | current | Local device card fiber port 1 D/D information: Wave length 2 |
| 1.3.6.1.4.1.4756.20.190.40.1.85 | Columnf100ASFx1DDLinkLenLocal | read-only | current | Local device card fiber port 1 D/D information: Link length |
| 1.3.6.1.4.1.4756.20.190.40.1.86 | Columnf100ASFx1DDLenUnitLocal | read-only | current | Local device card fiber port 1 D/D information: Length Unit |
| 1.3.6.1.4.1.4756.20.190.40.1.87 | Columnf100ASFx1DDStatusLocal | read-only | current | Local device card fiber port 1 D/D information: Status Support |
| 1.3.6.1.4.1.4756.20.190.40.1.88 | Columnf100ASFx1DDRxSensLocal | read-only | current | Local device card fiber port 1 D/D information: Rx Sensitivity |
| 1.3.6.1.4.1.4756.20.190.40.1.89 | Columnf100ASFx1DDTxPWRLocal | read-only | current | Local device card fiber port 1 D/D information: Tx power |
| 1.3.6.1.4.1.4756.20.190.40.1.90 | Columnf100ASFx1DDRxPWRLocal | read-only | current | Local device card fiber port 1 D/D information: Rx power |
| 1.3.6.1.4.1.4756.20.190.40.1.91 | Columnf100ASFx1DDTempLocal | read-only | current | Local device card fiber port 1 D/D information: Temperature in degree C |
| 1.3.6.1.4.1.4756.20.190.40.1.92 | Columnf100ASFx1DDPWRMarginLocal | read-only | current | Local device card fiber port 1 D/D information: Power margin |
| 1.3.6.1.4.1.4756.20.190.40.1.93 | Columnf100ASFx1DDPWRLossLocal | read-only | current | Local device card fiber port 1 D/D information: Power loss |
| 1.3.6.1.4.1.4756.20.190.40.1.94 | Columnf100ASFx2DDLocal | read-only | current | Local device card fiber port 2 Digital Diagnostic function: 0:No 1:Yes |
| 1.3.6.1.4.1.4756.20.190.40.1.95 | Columnf100ASFx2DDVendorLocal | read-only | current | Local device card fiber port 2 D/D information: Vendor name |
| 1.3.6.1.4.1.4756.20.190.40.1.96 | Columnf100ASFx2DDPartNoLocal | read-only | current | Local device card fiber port 2 D/D information: Vendor part number |
| 1.3.6.1.4.1.4756.20.190.40.1.97 | Columnf100ASFx2DDFiberTypeLocal | read-only | current | Local device card fiber port 2 D/D information: Fiber Type |
| 1.3.6.1.4.1.4756.20.190.40.1.98 | Columnf100ASFx2DDWaveLenLocal | read-only | current | Local device card fiber port 2 D/D information: Wave length |
| 1.3.6.1.4.1.4756.20.190.40.1.99 | Columnf100ASFx2DDWaveLen2Local | read-only | current | Local device card fiber port 2 D/D information: Wave length 2 |
| 1.3.6.1.4.1.4756.20.190.40.1.100 | Columnf100ASFx2DDLinkLenLocal | read-only | current | Local device card fiber port 2 D/D information: Link length |
| 1.3.6.1.4.1.4756.20.190.40.1.101 | Columnf100ASFx2DDLenUnitLocal | read-only | current | Local device card fiber port 2 D/D information: Length Unit |
| 1.3.6.1.4.1.4756.20.190.40.1.102 | Columnf100ASFx2DDStatusLocal | read-only | current | Local device card fiber port 2 D/D information: Status Support |
| 1.3.6.1.4.1.4756.20.190.40.1.103 | Columnf100ASFx2DDRxSensLocal | read-only | current | Local device card fiber port 2 D/D information: Rx Sensitivity |
| 1.3.6.1.4.1.4756.20.190.40.1.104 | Columnf100ASFx2DDTxPWRLocal | read-only | current | Local device card fiber port 2 D/D information: Tx power |
| 1.3.6.1.4.1.4756.20.190.40.1.105 | Columnf100ASFx2DDRxPWRLocal | read-only | current | Local device card fiber port 2 D/D information: Rx power |
| 1.3.6.1.4.1.4756.20.190.40.1.106 | Columnf100ASFx2DDTempLocal | read-only | current | Local device card fiber port 2 D/D information: Temperature in degree C |
| 1.3.6.1.4.1.4756.20.190.40.1.107 | Columnf100ASFx2DDPWRMarginLocal | read-only | current | Local device card fiber port 2 D/D information: Power margin |
| 1.3.6.1.4.1.4756.20.190.40.1.108 | Columnf100ASFx2DDPWRLossLocal | read-only | current | Local device card fiber port 2 D/D information: Power loss |
| 1.3.6.1.4.1.4756.20.190.40.1.109 | Columnf100ASClrRMONCntsLocal | read-write | current | Clear local device card RMON IN/OUT counters: 0:No action 1:Action |
| 1.3.6.1.4.1.4756.20.190.40.1.110 | Columnf100ASFx1RMONInLocal | read-only | current | Local device card port 1 RMON IN counter. |
| 1.3.6.1.4.1.4756.20.190.40.1.111 | Columnf100ASFx1RMONOutLocal | read-only | current | Local device card port 1 RMON OUT counter. |
| 1.3.6.1.4.1.4756.20.190.40.1.112 | Columnf100ASFx2RMONInLocal | read-only | current | Local device card port 2 RMON IN counter. |
| 1.3.6.1.4.1.4756.20.190.40.1.113 | Columnf100ASFx2RMONOutLocal | read-only | current | Local device card port 2 RMON OUT counter. |
| 1.3.6.1.4.1.4756.20.190.40.1.114 | Columnf100ASUtp1RMONInLocal | read-only | current | Local device card port 3 RMON IN counter. |
| 1.3.6.1.4.1.4756.20.190.40.1.115 | Columnf100ASUtp1RMONOutLocal | read-only | current | Local device card port 3 RMON OUT counter. |
| 1.3.6.1.4.1.4756.20.190.40.1.116 | Columnf100ASUtp2RMONInLocal | read-only | current | Local device card port 4 RMON IN counter. |
| 1.3.6.1.4.1.4756.20.190.40.1.117 | Columnf100ASUtp2RMONOutLocal | read-only | current | Local device card port 4 RMON OUT counter. |
| 1.3.6.1.4.1.4756.20.190.40.1.118 | Columnf100ASClrOAMCntsLocal | read-write | current | Clear local device card OAM counters: 0:No action 1:Action |
| 1.3.6.1.4.1.4756.20.190.40.1.119 | Columnf100ASOamChATxLocal | read-only | current | Local device OAM Channel A TX OAMPDU frame count |
| 1.3.6.1.4.1.4756.20.190.40.1.120 | Columnf100ASOamChARxLocal | read-only | current | Local device OAM Channel A RX OAMPDU frame count |
| 1.3.6.1.4.1.4756.20.190.40.1.121 | Columnf100ASOamInfoChATxLocal | read-only | current | Local device OAM Channel A TX Information OAMPDU frame count |
| 1.3.6.1.4.1.4756.20.190.40.1.122 | Columnf100ASOamInfoChARxLocal | read-only | current | Local device OAM Channel A RX Information OAMPDU frame count |
| 1.3.6.1.4.1.4756.20.190.40.1.123 | Columnf100ASOamEventChATxLocal | read-only | current | Local device OAM Channel A TX Event OAMPDU frame count |
| 1.3.6.1.4.1.4756.20.190.40.1.124 | Columnf100ASOamUniEvtChARxLocal | read-only | current | Local device OAM Channel A RX Unique Event OAMPDU frame count |
| 1.3.6.1.4.1.4756.20.190.40.1.125 | Columnf100ASOamDupEvtChARxLocal | read-only | current | Local device OAM Channel A RX Duplicate Event OAMPDU frame count |
| 1.3.6.1.4.1.4756.20.190.40.1.126 | Columnf100ASOamLbChATxLocal | read-only | current | Local device OAM Channel A TX Loopback Control OAMPDU frame count |
| 1.3.6.1.4.1.4756.20.190.40.1.127 | Columnf100ASOamLbChARxLocal | read-only | current | Local device OAM Channel A RX Loopback Control OAMPDU frame count |
| 1.3.6.1.4.1.4756.20.190.40.1.128 | Columnf100ASOamVarReqChATxLocal | read-only | current | Local device OAM Channel A TX Variable Request OAMPDU frame count |
| 1.3.6.1.4.1.4756.20.190.40.1.129 | Columnf100ASOamVarReqChARxLocal | read-only | current | Local device OAM Channel A RX Variable Request OAMPDU frame count |
| 1.3.6.1.4.1.4756.20.190.40.1.130 | Columnf100ASOamVarRspChATxLocal | read-only | current | Local device OAM Channel A TX Variable Response OAMPDU frame count |
| 1.3.6.1.4.1.4756.20.190.40.1.131 | Columnf100ASOamVarRspChARxLocal | read-only | current | Local device OAM Channel A RX Variable Response OAMPDU frame count |
| 1.3.6.1.4.1.4756.20.190.40.1.132 | Columnf100ASOamOuiChATxLocal | read-only | current | Local device OAM Channel A TX OUI OAMPDU frame count |
| 1.3.6.1.4.1.4756.20.190.40.1.133 | Columnf100ASOamOuiChARxLocal | read-only | current | Local device OAM Channel A RX OUI OAMPDU frame count |
| 1.3.6.1.4.1.4756.20.190.40.1.134 | Columnf100ASOamUnknowChARxLocal | read-only | current | Local device OAM Channel A RX Unsupported OAMPDU frame count |
| 1.3.6.1.4.1.4756.20.190.40.1.135 | Columnf100ASOamChBTxLocal | read-only | current | Local device OAM Channel B TX OAMPDU frame count |
| 1.3.6.1.4.1.4756.20.190.40.1.136 | Columnf100ASOamChBRxLocal | read-only | current | Local device OAM Channel B RX OAMPDU frame count |
| 1.3.6.1.4.1.4756.20.190.40.1.137 | Columnf100ASOamInfoChBTxLocal | read-only | current | Local device OAM Channel B TX Information OAMPDU frame count |
| 1.3.6.1.4.1.4756.20.190.40.1.138 | Columnf100ASOamInfoChBRxLocal | read-only | current | Local device OAM Channel B RX Information OAMPDU frame count |
| 1.3.6.1.4.1.4756.20.190.40.1.139 | Columnf100ASOamEventChBTxLocal | read-only | current | Local device OAM Channel B TX Event OAMPDU frame count |
| 1.3.6.1.4.1.4756.20.190.40.1.140 | Columnf100ASOamUniEvtChBRxLocal | read-only | current | Local device OAM Channel B RX Unique Event OAMPDU frame count |
| 1.3.6.1.4.1.4756.20.190.40.1.141 | Columnf100ASOamDupEvtChBRxLocal | read-only | current | Local device OAM Channel B RX Duplicate Event OAMPDU frame count |
| 1.3.6.1.4.1.4756.20.190.40.1.142 | Columnf100ASOamLbChBTxLocal | read-only | current | Local device OAM Channel B TX Loopback Control OAMPDU frame count |
| 1.3.6.1.4.1.4756.20.190.40.1.143 | Columnf100ASOamLbChBRxLocal | read-only | current | Local device OAM Channel B RX Loopback Control OAMPDU frame count |
| 1.3.6.1.4.1.4756.20.190.40.1.144 | Columnf100ASOamVarReqChBTxLocal | read-only | current | Local device OAM Channel B TX Variable Request OAMPDU frame count |
| 1.3.6.1.4.1.4756.20.190.40.1.145 | Columnf100ASOamVarReqChBRxLocal | read-only | current | Local device OAM Channel B RX Variable Request OAMPDU frame count |
| 1.3.6.1.4.1.4756.20.190.40.1.146 | Columnf100ASOamVarRspChBTxLocal | read-only | current | Local device OAM Channel B TX Variable Response OAMPDU frame count |
| 1.3.6.1.4.1.4756.20.190.40.1.147 | Columnf100ASOamVarRspChBRxLocal | read-only | current | Local device OAM Channel B RX Variable Response OAMPDU frame count |
| 1.3.6.1.4.1.4756.20.190.40.1.148 | Columnf100ASOamOuiChBTxLocal | read-only | current | Local device OAM Channel B TX OUI OAMPDU frame count |
| 1.3.6.1.4.1.4756.20.190.40.1.149 | Columnf100ASOamOuiChBRxLocal | read-only | current | Local device OAM Channel B RX OUI OAMPDU frame count |
| 1.3.6.1.4.1.4756.20.190.40.1.150 | Columnf100ASOamUnknowChBRxLocal | read-only | current | Local device OAM Channel B RX Unsupported OAMPDU frame count |
| 1.3.6.1.4.1.4756.20.190.40.1.151 | Columnf100ASFx1FEFLocal | read-only | current | Local card fiber1 detected Far End Fault: 0:Off 1:Detected |
| 1.3.6.1.4.1.4756.20.190.40.1.152 | Columnf100ASFx2FEFLocal | read-only | current | Local card fiber2 detected Far End Fault: 0:Off 1:Detected |
| 1.3.6.1.4.1.4756.20.190.40.1.153 | Columnf100ASIpModeLocal | read-write | current | On Rack Ip Mode: 0:Enable 1:Disable |
| 1.3.6.1.4.1.4756.20.190.40.1.154 | Columnf100ASFx1QosPriorityRateLocal | read-write | current | Local device Fiber 1 Qos Priority Rate Mode: 0:Disable 1:Enable |
| 1.3.6.1.4.1.4756.20.190.40.1.155 | Columnf100ASFx2QosPriorityRateLocal | read-write | current | Local device Fiber 2 Qos Priority Rate Mode: 0:Disable 1:Enable |
| 1.3.6.1.4.1.4756.20.190.40.1.156 | Columnf100ASUtp1QosPriorityRateLocal | read-write | current | Local device Utp 3 Qos Priority Rate Mode: 0:Disable 1:Enable |
| 1.3.6.1.4.1.4756.20.190.40.1.157 | Columnf100ASUtp2QosPriorityRateLocal | read-write | current | Local device Utp 4 Qos Priority Rate Mode: 0:Disable 1:Enable |
| 1.3.6.1.4.1.4756.20.190.40.1.158 | Columnf100ASFx1QosPortPriorityLocal | read-write | current | Local device Fiber 1 Qos Port Priority : 0:priority 0 1:priority 1 2:priority 2 3:priority 3 |
| 1.3.6.1.4.1.4756.20.190.40.1.159 | Columnf100ASFx2QosPortPriorityLocal | read-write | current | Local device Fiber 2 Qos Port Priority : 0:priority 0 1:priority 1 2:priority 2 3:priority 3 |
| 1.3.6.1.4.1.4756.20.190.40.1.160 | Columnf100ASUtp1QosPortPriorityLocal | read-write | current | Local device Utp3 Qos Port Priority : 0:priority 0 1:priority 1 2:priority 2 3:priority 3 |
| 1.3.6.1.4.1.4756.20.190.40.1.161 | Columnf100ASUtp2QosPortPriorityLocal | read-write | current | Local device Utp4 Qos Port Priority : 0:priority 0 1:priority 1 2:priority 2 3:priority 3 |
| 1.3.6.1.4.1.4756.20.190.40.1.162 | Columnf100ASSetDefaultLocal | read-write | current | Local device Set to default: 0:Off 1:Action |
| 1.3.6.1.4.1.4756.20.191 | Nodef100ASRemoteACards | |||
| 1.3.6.1.4.1.4756.20.191.40 | Tablef100ASRemoteATable | not-accessible | current | A list of local frm220-100AS card entries. The number of entries is f100AS-NoRemoteA. |
| 1.3.6.1.4.1.4756.20.191.40.1 | Rowf100ASRemoteAEntry | not-accessible | current | An entry containing management information applicable to a particular local frm220-100AS card. |
| 1.3.6.1.4.1.4756.20.191.40.1.1 | Columnf100ASChassisIndexRemoteA | read-only | current | A unique value for each local card. It is the chassis location number. |
| 1.3.6.1.4.1.4756.20.191.40.1.2 | Columnf100ASSlotIndexRemoteA | read-only | current | A unique value for each local card. It is the slot location number. |
| 1.3.6.1.4.1.4756.20.191.40.1.3 | Columnf100ASCardHWVerRemoteA | read-only | current | Remote device card hardware version x.xxx |
| 1.3.6.1.4.1.4756.20.191.40.1.4 | Columnf100ASCardFWVerRemoteA | read-only | current | Remote device card firmware version x.xxx |
| 1.3.6.1.4.1.4756.20.191.40.1.5 | Columnf100ASCardCPLDVerRemoteA | read-only | current | Remote device card CPLD version x.xxx |
| 1.3.6.1.4.1.4756.20.191.40.1.6 | Columnf100ASCardFPGAVerRemoteA | read-only | current | Remote device card FPGA version x.xxx |
| 1.3.6.1.4.1.4756.20.191.40.1.7 | Columnf100ASModelRemoteA | read-only | current | Remote frm220 f100AS Serial Type |
| 1.3.6.1.4.1.4756.20.191.40.1.8 | Columnf100ASFx1LinkRemoteA | read-only | current | Remote device card fiber port 1 link status: 0:Down 1:Up |
| 1.3.6.1.4.1.4756.20.191.40.1.9 | Columnf100ASFx1OAMLoopedRemoteA | read-only | current | Remote device card fiber port 1 OAM looped: 0:Off 1:on |
| 1.3.6.1.4.1.4756.20.191.40.1.10 | Columnf100ASFx1LBTestRemoteA | read-write | current | Force remote device card to do fiber port 1 LoopBack testing: 0:Off 1:Action |
| 1.3.6.1.4.1.4756.20.191.40.1.11 | Columnf100ASFx1OAMRLBStatusRemoteA | read-only | current | Remote device card fiber port 1 LoopBack testing status: 0:Off 1:Ok 2:Fail |
| 1.3.6.1.4.1.4756.20.191.40.1.12 | Columnf100ASFx1RemoPwrAbRemoteA | read-only | current | Remote device card fiber port 1 Remote Power status: 0:Abnormal 1:OK 2:None |
| 1.3.6.1.4.1.4756.20.191.40.1.13 | Columnf100ASFx2LinkRemoteA | read-only | current | Remote device card fiber port 2 link status: 0:Down 1:Up |
| 1.3.6.1.4.1.4756.20.191.40.1.14 | Columnf100ASFx2OAMLoopedRemoteA | read-only | current | Remote device card fiber port 2 OAM looped: 0:Off 1:on |
| 1.3.6.1.4.1.4756.20.191.40.1.15 | Columnf100ASFx2LBTestRemoteA | read-write | current | Force remote device card to do fiber port 2 LoopBack testing: 0:Off 1:Action |
| 1.3.6.1.4.1.4756.20.191.40.1.16 | Columnf100ASFx2OAMRLBStatusRemoteA | read-only | current | Remote device card fiber port 1 LoopBack testing status: 0:Off 1:Ok 2:Fail |
| 1.3.6.1.4.1.4756.20.191.40.1.17 | Columnf100ASFx2RemoPwrAbRemoteA | read-only | current | Remote device card fiber port 2 Remote Power status: 0:Abnormal 1:OK 2:None |
| 1.3.6.1.4.1.4756.20.191.40.1.18 | Columnf100ASUtp1LinkRemoteA | read-only | current | Remote device card UTP port 3 link status: 0:Down 1:Up |
| 1.3.6.1.4.1.4756.20.191.40.1.19 | Columnf100ASUtp1NegoRemoteA | read-write | current | Remote device card UTP port 3 negotiation status: 0:Manual 1:Auto |
| 1.3.6.1.4.1.4756.20.191.40.1.20 | Columnf100ASUtp1SpeedRemoteA | read-write | current | Remote device card UTP port 3 speed setting: 0:10 Base-T 1:100 Base-TX |
| 1.3.6.1.4.1.4756.20.191.40.1.21 | Columnf100ASUtp1DuplexRemoteA | read-write | current | Remote device card UTP port 3 duplex setting: 0:Half duplex mode 1:Full duplex mode |
| 1.3.6.1.4.1.4756.20.191.40.1.22 | Columnf100ASUtp1SpeedStatusRemoteA | read-only | current | Remote device card UTP port 3 speed status: 0:10 Base-T 1:100 Base-TX |
| 1.3.6.1.4.1.4756.20.191.40.1.23 | Columnf100ASUtp1DuplexStatusRemoteA | read-only | current | Remote device card UTP port 3 duplex status: 0:Half duplex mode 1:Full duplex mode |
| 1.3.6.1.4.1.4756.20.191.40.1.24 | Columnf100ASUtp2LinkRemoteA | read-only | current | Remote device card UTP port 4 link status: 0:Down 1:Up |
| 1.3.6.1.4.1.4756.20.191.40.1.25 | Columnf100ASUtp2NegoRemoteA | read-write | current | Remote device card UTP port 4 negotiation status: 0:Manual 1:Auto |
| 1.3.6.1.4.1.4756.20.191.40.1.26 | Columnf100ASUtp2SpeedRemoteA | read-write | current | Remote device card UTP port 4 speed setting: 0:10 Base-T 1:100 Base-TX |
| 1.3.6.1.4.1.4756.20.191.40.1.27 | Columnf100ASUtp2DuplexRemoteA | read-write | current | Remote device card UTP port 2 duplex setting: 0:Half duplex mode 1:Full duplex mode |
| 1.3.6.1.4.1.4756.20.191.40.1.28 | Columnf100ASUtp2SpeedStatusRemoteA | read-only | current | Remote device card UTP port 4 speed status: 0:10 Base-T 1:100 Base-TX |
| 1.3.6.1.4.1.4756.20.191.40.1.29 | Columnf100ASUtp2DuplexStatusRemoteA | read-only | current | Remote device card UTP port 2 duplex status: 0:Half duplex mode 1:Full duplex mode |
| 1.3.6.1.4.1.4756.20.191.40.1.30 | Columnf100ASFx1IrlModeRemoteA | read-write | current | Remote device card port 1 Rate Limit mode: 0:unlimited 1:limited |
| 1.3.6.1.4.1.4756.20.191.40.1.31 | Columnf100ASFx1IrlIndexRemoteA | read-write | current | Remote device card port 1 Ingress Rate Limit index: Index Limit Rate 0 Disable 1 128K 2 256K 3 512K 4 1M 5 2M 6 4M 7 8M |
| 1.3.6.1.4.1.4756.20.191.40.1.32 | Columnf100ASFx1ErlIndexRemoteA | read-write | current | Remote device card port 1 Egress Rate Limit index: Index Limit Rate 0 Disable 1 128K 2 256K 3 512K 4 1M 5 2M 6 4M 7 8M |
| 1.3.6.1.4.1.4756.20.191.40.1.33 | Columnf100ASFx2IrlModeRemoteA | read-write | current | Remote device card port 2 Rate Limit mode: 0:unlimited 1:limited |
| 1.3.6.1.4.1.4756.20.191.40.1.34 | Columnf100ASFx2IrlIndexRemoteA | read-write | current | Remote device card port 2 Ingress Rate Limit index: Index Limit Rate 0 Disable 1 128K 2 256K 3 512K 4 1M 5 2M 6 4M 7 8M |
| 1.3.6.1.4.1.4756.20.191.40.1.35 | Columnf100ASFx2ErlIndexRemoteA | read-write | current | Remote device card port 2 Egress Rate Limit index: Index Limit Rate 0 Disable 1 128K 2 256K 3 512K 4 1M 5 2M 6 4M 7 8M |
| 1.3.6.1.4.1.4756.20.191.40.1.36 | Columnf100ASUtp1IrlModeRemoteA | read-write | current | Remote device card port 3 Rate Limit mode: 0:unlimited 1:limited |
| 1.3.6.1.4.1.4756.20.191.40.1.37 | Columnf100ASUtp1IrlIndexRemoteA | read-write | current | Remote device card port 3 Ingress Rate Limit index: Index Limit Rate 0 Disable 1 128K 2 256K 3 512K 4 1M 5 2M 6 4M 7 8M |
| 1.3.6.1.4.1.4756.20.191.40.1.38 | Columnf100ASUtp1ErlIndexRemoteA | read-write | current | Remote device card port 3 Egress Rate Limit index: Index Limit Rate 0 Disable 1 128K 2 256K 3 512K 4 1M 5 2M 6 4M 7 8M |
| 1.3.6.1.4.1.4756.20.191.40.1.39 | Columnf100ASUtp2IrlModeRemoteA | read-write | current | Remote device card port 4 Rate Limit mode: 0:unlimited 1:limited |
| 1.3.6.1.4.1.4756.20.191.40.1.40 | Columnf100ASUtp2IrlIndexRemoteA | read-write | current | Remote device card port 4 Ingress Rate Limit index: Index Limit Rate 0 Disable 1 128K 2 256K 3 512K 4 1M 5 2M 6 4M 7 8M |
| 1.3.6.1.4.1.4756.20.191.40.1.41 | Columnf100ASUtp2ErlIndexRemoteA | read-write | current | Remote device card port 4 Egress Rate Limit index: Index Limit Rate 0 Disable 1 128K 2 256K 3 512K 4 1M 5 2M 6 4M 7 8M |
| 1.3.6.1.4.1.4756.20.191.40.1.42 | Columnf100ASDeviceActiveRemoteA | read-only | current | Remote device card active mode: (It is read-only in local device.) 0:Disable 1:Enable |
| 1.3.6.1.4.1.4756.20.191.40.1.43 | Columnf100ASDeviceResetRemoteA | read-write | current | Force remote device card to reset mode: 0:Off 1:Action |
| 1.3.6.1.4.1.4756.20.191.40.1.44 | Columnf100ASFx1ActiveRemoteA | read-only | current | Remote device fiber port 1 active mode: 0:Disable 1:Enable |
| 1.3.6.1.4.1.4756.20.191.40.1.45 | Columnf100ASFx2ActiveRemoteA | read-only | current | Remote device fiber port 2 active mode: 0:Disable 1:Enable |
| 1.3.6.1.4.1.4756.20.191.40.1.46 | Columnf100ASUtp1ActiveRemoteA | read-write | current | Remote device UTP port 3 active mode: 0:Disable 1:Enable |
| 1.3.6.1.4.1.4756.20.191.40.1.47 | Columnf100ASUtp2ActiveRemoteA | read-write | current | Remote device UTP port 4 active mode: 0:Disable 1:Enable |
| 1.3.6.1.4.1.4756.20.191.40.1.48 | Columnf100ASOamChAModeRemoteA | read-write | current | Remote device OAM Channel A mode: 0:Passive 1:Active |
| 1.3.6.1.4.1.4756.20.191.40.1.49 | Columnf100ASOamChBModeRemoteA | read-write | current | Remote device OAM Channel B mode: 0:Passive 1:Active |
| 1.3.6.1.4.1.4756.20.191.40.1.50 | Columnf100ASOamMaxPDUsRemoteA | read-write | current | Remote device OAM max OAMPDU size: 60-1518 Octets |
| 1.3.6.1.4.1.4756.20.191.40.1.51 | Columnf100ASFx1AlsRemoteA | read-write | current | Remote device card port 1 Auto Laser Shutdown mode: 0:Disable 1:Enable |
| 1.3.6.1.4.1.4756.20.191.40.1.52 | Columnf100ASFx2AlsRemoteA | read-write | current | Remote device card port 2 Auto Laser Shutdown mode: 0:Disable 1:Enable |
| 1.3.6.1.4.1.4756.20.191.40.1.53 | Columnf100ASPauseFrameRemoteA | read-write | current | Remote device card pause frame mode: 0:Disable 1:Enable |
| 1.3.6.1.4.1.4756.20.191.40.1.54 | Columnf100ASFhrModeRemoteA | read-write | current | Remote device card accepts remote Fiber Hardware Reset mode: 0:Disable 1:Enable |
| 1.3.6.1.4.1.4756.20.191.40.1.55 | Columnf100ASFx1LLFDepLogiRemoteA | read-write | current | Remote device card port 1 Link Loss Forwarding depends boolean logic: 0:and 1:or |
| 1.3.6.1.4.1.4756.20.191.40.1.56 | Columnf100ASFx1LLFDepPort2RemoteA | read-write | current | Remote device card port 1 Link Loss Forwarding depends on port 2 Fiber Rx link: 0:don't care 1:selected |
| 1.3.6.1.4.1.4756.20.191.40.1.57 | Columnf100ASFx1LLFDepPort3RemoteA | read-write | current | Remote device card port 1 Link Loss Forwarding depends on port 3 Ethernet Rx link: 0:don't care 1:selected |
| 1.3.6.1.4.1.4756.20.191.40.1.58 | Columnf100ASFx1LLFDepPort4RemoteA | read-write | current | Remote device card port 1 Link Loss Forwarding depends on port 4 Ethernet Rx link: 0:don't care 1:selected |
| 1.3.6.1.4.1.4756.20.191.40.1.59 | Columnf100ASFx2LLFDepLogiRemoteA | read-write | current | Remote device card port 2 Link Loss Forwarding depends boolean logic: 0:and 1:or |
| 1.3.6.1.4.1.4756.20.191.40.1.60 | Columnf100ASFx2LLFDepPort1RemoteA | read-write | current | Remote device card port 2 Link Loss Forwarding depends on port 1 Fiber Rx link: 0:don't care 1:selected |
| 1.3.6.1.4.1.4756.20.191.40.1.61 | Columnf100ASFx2LLFDepPort3RemoteA | read-write | current | Remote device card port 2 Link Loss Forwarding depends on port 3 Ethernet Rx link: 0:don't care 1:selected |
| 1.3.6.1.4.1.4756.20.191.40.1.62 | Columnf100ASFx2LLFDepPort4RemoteA | read-write | current | Remote device card port 2 Link Loss Forwarding depends on port 4 Ethernet Rx link: 0:don't care 1:selected |
| 1.3.6.1.4.1.4756.20.191.40.1.63 | Columnf100ASUtp1LLFDepLogiRemoteA | read-write | current | Remote device card port 3 Link Loss Forwarding depends boolean logic: 0:and 1:or |
| 1.3.6.1.4.1.4756.20.191.40.1.64 | Columnf100ASUtp1LLFDepPort1RemoteA | read-write | current | Remote device card port 3 Link Loss Forwarding depends on port 1 Fiber Rx link: 0:don't care 1:selected |
| 1.3.6.1.4.1.4756.20.191.40.1.65 | Columnf100ASUtp1LLFDepPort2RemoteA | read-write | current | Remote device card port 3 Link Loss Forwarding depends on port 2 Fiber Rx link: 0:don't care 1:selected |
| 1.3.6.1.4.1.4756.20.191.40.1.66 | Columnf100ASUtp2LLFDepLogiRemoteA | read-write | current | Remote device card port 4 Link Loss Forwarding depends boolean logic: 0:and 1:or |
| 1.3.6.1.4.1.4756.20.191.40.1.67 | Columnf100ASUtp2LLFDepPort1RemoteA | read-write | current | Remote device card port 4 Link Loss Forwarding depends on port 1 Fiber Rx link: 0:don't care 1:selected |
| 1.3.6.1.4.1.4756.20.191.40.1.68 | Columnf100ASUtp2LLFDepPort2RemoteA | read-write | current | Remote device card port 4 Link Loss Forwarding depends on port 2 Fiber Rx link: 0:don't care 1:selected |
| 1.3.6.1.4.1.4756.20.191.40.1.69 | Columnf100ASAdvanceFunsRemoteA | read-write | current | Remote device card Switch functions mode: 0:Normal 2:Port 1&2 Mirror 3:Port VLAN 1/3;2/4 4:Port 1&2 Redundancy 5:Static 802.1Q VLAN 6:Spanning Tree protocol 7:… |
| 1.3.6.1.4.1.4756.20.191.40.1.70 | Columnf100ASFx1InfoROM1RemoteA | read-only | current | Remote device card port 1 INFORemoteOM information 1 valid: 0:Invalid 1:Valid |
| 1.3.6.1.4.1.4756.20.191.40.1.71 | Columnf100ASFx1InfoROM2RemoteA | read-only | current | Remote device card port 1 INFORemoteOM information 2 valid: 0:Invalid 1:Valid(replacing D/D function |
| 1.3.6.1.4.1.4756.20.191.40.1.72 | Columnf100ASFx2InfoROM1RemoteA | read-only | current | Remote device card port 2 INFORemoteOM information 1 valid: 0:Invalid 1:Valid |
| 1.3.6.1.4.1.4756.20.191.40.1.73 | Columnf100ASFx2InfoROM2RemoteA | read-only | current | Remote device card port 2 INFORemoteOM information 2 valid: 0:Invalid 1:Valid(replacing D/D function) |
| 1.3.6.1.4.1.4756.20.191.40.1.74 | Columnf100ASFx1InfoSN1RemoteA | read-only | current | Remote device card port 1 INFORemoteOM S/N 1 |
| 1.3.6.1.4.1.4756.20.191.40.1.75 | Columnf100ASFx1InfoSN2RemoteA | read-only | current | Remote device card port 1 INFORemoteOM S/N 2 |
| 1.3.6.1.4.1.4756.20.191.40.1.76 | Columnf100ASFx2InfoSN1RemoteA | read-only | current | Remote device card port 2 INFORemoteOM S/N 1 |
| 1.3.6.1.4.1.4756.20.191.40.1.77 | Columnf100ASFx2InfoSN2RemoteA | read-only | current | Remote device card port 2 INFORemoteOM S/N 2 |
| 1.3.6.1.4.1.4756.20.191.40.1.78 | Columnf100ASFx1DDRemoteA | read-only | current | Remote device card fiber port 1 Digital Diagnostic function: 0:No 1:Yes |
| 1.3.6.1.4.1.4756.20.191.40.1.79 | Columnf100ASFx1DDVendorRemoteA | read-only | current | Remote device card fiber port 1 D/D information: Vendor name |
| 1.3.6.1.4.1.4756.20.191.40.1.80 | Columnf100ASFx1DDPartNoRemoteA | read-only | current | Remote device card fiber port 1 D/D information: Vendor part number |
| 1.3.6.1.4.1.4756.20.191.40.1.81 | Columnf100ASFx1DDFiberTypeRemoteA | read-only | current | Remote device card fiber port 1 D/D information: Fiber Type |
| 1.3.6.1.4.1.4756.20.191.40.1.82 | Columnf100ASFx1DDWaveLenRemoteA | read-only | current | Remote device card fiber port 1 D/D information: Wave length |
| 1.3.6.1.4.1.4756.20.191.40.1.83 | Columnf100ASFx1DDWaveLen2RemoteA | read-only | current | Remote device card fiber port 1 D/D information: Wave length 2 |
| 1.3.6.1.4.1.4756.20.191.40.1.84 | Columnf100ASFx1DDLinkLenRemoteA | read-only | current | Remote device card fiber port 1 D/D information: Link length |
| 1.3.6.1.4.1.4756.20.191.40.1.85 | Columnf100ASFx1DDLenUnitRemoteA | read-only | current | Remote device card fiber port 1 D/D information: Length Unit |
| 1.3.6.1.4.1.4756.20.191.40.1.86 | Columnf100ASFx1DDStatusRemoteA | read-only | current | Remote device card fiber port 1 D/D information: Status Support |
| 1.3.6.1.4.1.4756.20.191.40.1.87 | Columnf100ASFx1DDRxSensRemoteA | read-only | current | Remote device card fiber port 1 D/D information: Rx Sensitivity |
| 1.3.6.1.4.1.4756.20.191.40.1.88 | Columnf100ASFx1DDTxPWRRemoteA | read-only | current | Remote device card fiber port 1 D/D information: Tx power |
| 1.3.6.1.4.1.4756.20.191.40.1.89 | Columnf100ASFx1DDRxPWRRemoteA | read-only | current | Remote device card fiber port 1 D/D information: Rx power |
| 1.3.6.1.4.1.4756.20.191.40.1.90 | Columnf100ASFx1DDTempRemoteA | read-only | current | Remote device card fiber port 1 D/D information: Temperature in degree C |
| 1.3.6.1.4.1.4756.20.191.40.1.91 | Columnf100ASFx1DDPWRMarginRemoteA | read-only | current | Remote device card fiber port 1 D/D information: Power margin |
| 1.3.6.1.4.1.4756.20.191.40.1.92 | Columnf100ASFx1DDPWRLossRemoteA | read-only | current | Remote device card fiber port 1 D/D information: Power loss |
| 1.3.6.1.4.1.4756.20.191.40.1.93 | Columnf100ASFx2DDRemoteA | read-only | current | Remote device card fiber port 2 Digital Diagnostic function: 0:No 1:Yes |
| 1.3.6.1.4.1.4756.20.191.40.1.94 | Columnf100ASFx2DDVendorRemoteA | read-only | current | Remote device card fiber port 2 D/D information: Vendor name |
| 1.3.6.1.4.1.4756.20.191.40.1.95 | Columnf100ASFx2DDPartNoRemoteA | read-only | current | Remote device card fiber port 2 D/D information: Vendor part number |
| 1.3.6.1.4.1.4756.20.191.40.1.96 | Columnf100ASFx2DDFiberTypeRemoteA | read-only | current | Remote device card fiber port 2 D/D information: Fiber Type |
| 1.3.6.1.4.1.4756.20.191.40.1.97 | Columnf100ASFx2DDWaveLenRemoteA | read-only | current | Remote device card fiber port 2 D/D information: Wave length |
| 1.3.6.1.4.1.4756.20.191.40.1.98 | Columnf100ASFx2DDWaveLen2RemoteA | read-only | current | Remote device card fiber port 2 D/D information: Wave length 2 |
| 1.3.6.1.4.1.4756.20.191.40.1.99 | Columnf100ASFx2DDLinkLenRemoteA | read-only | current | Remote device card fiber port 2 D/D information: Link length |
| 1.3.6.1.4.1.4756.20.191.40.1.100 | Columnf100ASFx2DDLenUnitRemoteA | read-only | current | Remote device card fiber port 2 D/D information: Length Unit |
| 1.3.6.1.4.1.4756.20.191.40.1.101 | Columnf100ASFx2DDStatusRemoteA | read-only | current | Remote device card fiber port 2 D/D information: Status Support |
| 1.3.6.1.4.1.4756.20.191.40.1.102 | Columnf100ASFx2DDRxSensRemoteA | read-only | current | Remote device card fiber port 2 D/D information: Rx Sensitivity |
| 1.3.6.1.4.1.4756.20.191.40.1.103 | Columnf100ASFx2DDTxPWRRemoteA | read-only | current | Remote device card fiber port 2 D/D information: Tx power |
| 1.3.6.1.4.1.4756.20.191.40.1.104 | Columnf100ASFx2DDRxPWRRemoteA | read-only | current | Remote device card fiber port 2 D/D information: Rx power |
| 1.3.6.1.4.1.4756.20.191.40.1.105 | Columnf100ASFx2DDTempRemoteA | read-only | current | Remote device card fiber port 2 D/D information: Temperature in degree C |
| 1.3.6.1.4.1.4756.20.191.40.1.106 | Columnf100ASFx2DDPWRMarginRemoteA | read-only | current | Remote device card fiber port 2 D/D information: Power margin |
| 1.3.6.1.4.1.4756.20.191.40.1.107 | Columnf100ASFx2DDPWRLossRemoteA | read-only | current | Remote device card fiber port 2 D/D information: Power loss |
| 1.3.6.1.4.1.4756.20.191.40.1.108 | Columnf100ASClrRMONCntsRemoteA | read-write | current | Clear local device card RMON IN/OUT counters: 0:No action 1:Action |
| 1.3.6.1.4.1.4756.20.191.40.1.109 | Columnf100ASFx1RMONInRemoteA | read-only | current | Remote device card port 1 RMON IN counter. |
| 1.3.6.1.4.1.4756.20.191.40.1.110 | Columnf100ASFx1RMONOutRemoteA | read-only | current | Remote device card port 1 RMON OUT counter. |
| 1.3.6.1.4.1.4756.20.191.40.1.111 | Columnf100ASFx2RMONInRemoteA | read-only | current | Remote device card port 2 RMON IN counter. |
| 1.3.6.1.4.1.4756.20.191.40.1.112 | Columnf100ASFx2RMONOutRemoteA | read-only | current | Remote device card port 2 RMON OUT counter. |
| 1.3.6.1.4.1.4756.20.191.40.1.113 | Columnf100ASUtp1RMONInRemoteA | read-only | current | Remote device card port 3 RMON IN counter. |
| 1.3.6.1.4.1.4756.20.191.40.1.114 | Columnf100ASUtp1RMONOutRemoteA | read-only | current | Remote device card port 3 RMON OUT counter. |
| 1.3.6.1.4.1.4756.20.191.40.1.115 | Columnf100ASUtp2RMONInRemoteA | read-only | current | Remote device card port 4 RMON IN counter. |
| 1.3.6.1.4.1.4756.20.191.40.1.116 | Columnf100ASUtp2RMONOutRemoteA | read-only | current | Remote device card port 4 RMON OUT counter. |
| 1.3.6.1.4.1.4756.20.191.40.1.117 | Columnf100ASClrOAMCntsRemoteA | read-write | current | Clear local device card OAM counters: 0:No action 1:Action |
| 1.3.6.1.4.1.4756.20.191.40.1.118 | Columnf100ASOamChATxRemoteA | read-only | current | Remote device OAM Channel A TX OAMPDU frame count |
| 1.3.6.1.4.1.4756.20.191.40.1.119 | Columnf100ASOamChARxRemoteA | read-only | current | Remote device OAM Channel A RX OAMPDU frame count |
| 1.3.6.1.4.1.4756.20.191.40.1.120 | Columnf100ASOamInfoChATxRemoteA | read-only | current | Remote device OAM Channel A TX Information OAMPDU frame count |
| 1.3.6.1.4.1.4756.20.191.40.1.121 | Columnf100ASOamInfoChARxRemoteA | read-only | current | Remote device OAM Channel A RX Information OAMPDU frame count |
| 1.3.6.1.4.1.4756.20.191.40.1.122 | Columnf100ASOamEventChATxRemoteA | read-only | current | Remote device OAM Channel A TX Event OAMPDU frame count |
| 1.3.6.1.4.1.4756.20.191.40.1.123 | Columnf100ASOamUniEvtChARxRemoteA | read-only | current | Remote device OAM Channel A RX Unique Event OAMPDU frame count |
| 1.3.6.1.4.1.4756.20.191.40.1.124 | Columnf100ASOamDupEvtChARxRemoteA | read-only | current | Remote device OAM Channel A RX Duplicate Event OAMPDU frame count |
| 1.3.6.1.4.1.4756.20.191.40.1.125 | Columnf100ASOamLbChATxRemoteA | read-only | current | Remote device OAM Channel A TX Loopback Control OAMPDU frame count |
| 1.3.6.1.4.1.4756.20.191.40.1.126 | Columnf100ASOamLbChARxRemoteA | read-only | current | Remote device OAM Channel A RX Loopback Control OAMPDU frame count |
| 1.3.6.1.4.1.4756.20.191.40.1.127 | Columnf100ASOamVarReqChATxRemoteA | read-only | current | Remote device OAM Channel A TX Variable Request OAMPDU frame count |
| 1.3.6.1.4.1.4756.20.191.40.1.128 | Columnf100ASOamVarReqChARxRemoteA | read-only | current | Remote device OAM Channel A RX Variable Request OAMPDU frame count |
| 1.3.6.1.4.1.4756.20.191.40.1.129 | Columnf100ASOamVarRspChATxRemoteA | read-only | current | Remote device OAM Channel A TX Variable Response OAMPDU frame count |
| 1.3.6.1.4.1.4756.20.191.40.1.130 | Columnf100ASOamVarRspChARxRemoteA | read-only | current | Remote device OAM Channel A RX Variable Response OAMPDU frame count |
| 1.3.6.1.4.1.4756.20.191.40.1.131 | Columnf100ASOamOuiChATxRemoteA | read-only | current | Remote device OAM Channel A TX OUI OAMPDU frame count |
| 1.3.6.1.4.1.4756.20.191.40.1.132 | Columnf100ASOamOuiChARxRemoteA | read-only | current | Remote device OAM Channel A RX OUI OAMPDU frame count |
| 1.3.6.1.4.1.4756.20.191.40.1.133 | Columnf100ASOamUnknowChARxRemoteA | read-only | current | Remote device OAM Channel A RX Unsupported OAMPDU frame count |
| 1.3.6.1.4.1.4756.20.191.40.1.134 | Columnf100ASOamChBTxRemoteA | read-only | current | Remote device OAM Channel B TX OAMPDU frame count |
| 1.3.6.1.4.1.4756.20.191.40.1.135 | Columnf100ASOamChBRxRemoteA | read-only | current | Remote device OAM Channel B RX OAMPDU frame count |
| 1.3.6.1.4.1.4756.20.191.40.1.136 | Columnf100ASOamInfoChBTxRemoteA | read-only | current | Remote device OAM Channel B TX Information OAMPDU frame count |
| 1.3.6.1.4.1.4756.20.191.40.1.137 | Columnf100ASOamInfoChBRxRemoteA | read-only | current | Remote device OAM Channel B RX Information OAMPDU frame count |
| 1.3.6.1.4.1.4756.20.191.40.1.138 | Columnf100ASOamEventChBTxRemoteA | read-only | current | Remote device OAM Channel B TX Event OAMPDU frame count |
| 1.3.6.1.4.1.4756.20.191.40.1.139 | Columnf100ASOamUniEvtChBRxRemoteA | read-only | current | Remote device OAM Channel B RX Unique Event OAMPDU frame count |
| 1.3.6.1.4.1.4756.20.191.40.1.140 | Columnf100ASOamDupEvtChBRxRemoteA | read-only | current | Remote device OAM Channel B RX Duplicate Event OAMPDU frame count |
| 1.3.6.1.4.1.4756.20.191.40.1.141 | Columnf100ASOamLbChBTxRemoteA | read-only | current | Remote device OAM Channel B TX Loopback Control OAMPDU frame count |
| 1.3.6.1.4.1.4756.20.191.40.1.142 | Columnf100ASOamLbChBRxRemoteA | read-only | current | Remote device OAM Channel B RX Loopback Control OAMPDU frame count |
| 1.3.6.1.4.1.4756.20.191.40.1.143 | Columnf100ASOamVarReqChBTxRemoteA | read-only | current | Remote device OAM Channel B TX Variable Request OAMPDU frame count |
| 1.3.6.1.4.1.4756.20.191.40.1.144 | Columnf100ASOamVarReqChBRxRemoteA | read-only | current | Remote device OAM Channel B RX Variable Request OAMPDU frame count |
| 1.3.6.1.4.1.4756.20.191.40.1.145 | Columnf100ASOamVarRspChBTxRemoteA | read-only | current | Remote device OAM Channel B TX Variable Response OAMPDU frame count |
| 1.3.6.1.4.1.4756.20.191.40.1.146 | Columnf100ASOamVarRspChBRxRemoteA | read-only | current | Remote device OAM Channel B RX Variable Response OAMPDU frame count |
| 1.3.6.1.4.1.4756.20.191.40.1.147 | Columnf100ASOamOuiChBTxRemoteA | read-only | current | Remote device OAM Channel B TX OUI OAMPDU frame count |
| 1.3.6.1.4.1.4756.20.191.40.1.148 | Columnf100ASOamOuiChBRxRemoteA | read-only | current | Remote device OAM Channel B RX OUI OAMPDU frame count |
| 1.3.6.1.4.1.4756.20.191.40.1.149 | Columnf100ASOamUnknowChBRxRemoteA | read-only | current | Remote device OAM Channel B RX Unsupported OAMPDU frame count |
| 1.3.6.1.4.1.4756.20.191.40.1.150 | Columnf100ASFx1FEFRemoteA | read-only | current | Remote card fiber1 detected Far End Fault: 0:Off 1:Detected |
| 1.3.6.1.4.1.4756.20.191.40.1.151 | Columnf100ASFx2FEFRemoteA | read-only | current | Remote card fiber2 detected Far End Fault: 0:Off 1:Detected |
| 1.3.6.1.4.1.4756.20.191.40.1.152 | Columnf100ASPower1RemoteA | read-only | current | Remote card OFC type power1 status: 0:Normal 1:Fail 2:None |
| 1.3.6.1.4.1.4756.20.191.40.1.153 | Columnf100ASPower2RemoteA | read-only | current | Remote card OFC type power2 status: 0:Normal 1:Fail 2:None |
| 1.3.6.1.4.1.4756.20.191.40.1.154 | Columnf100ASIpModeRemoteA | read-write | current | On Rack Ip Mode: 0:Enable 1:Disable |
| 1.3.6.1.4.1.4756.20.191.40.1.155 | Columnf100ASFx1QosPriorityRateRemoteA | read-write | current | Local device Fiber 1 Qos Priority Rate Mode: 0:Disable 1:Enable |
| 1.3.6.1.4.1.4756.20.191.40.1.156 | Columnf100ASFx2QosPriorityRateRemoteA | read-write | current | Local device Fiber 2 Qos Priority Rate Mode: 0:Disable 1:Enable |
| 1.3.6.1.4.1.4756.20.191.40.1.157 | Columnf100ASUtp1QosPriorityRateRemoteA | read-write | current | Remote device Utp 3 Qos Priority Rate Mode: 0:Disable 1:Enable |
| 1.3.6.1.4.1.4756.20.191.40.1.158 | Columnf100ASUtp2QosPriorityRateRemoteA | read-write | current | Remote device Utp 4 Qos Priority Rate Mode: 0:Disable 1:Enable |
| 1.3.6.1.4.1.4756.20.191.40.1.159 | Columnf100ASFx1QosPortPriorityRemoteA | read-write | current | Remote device Fiber 1 Qos Port Priority : 0:priority 0 1:priority 1 2:priority 2 3:priority 3 |
| 1.3.6.1.4.1.4756.20.191.40.1.160 | Columnf100ASFx2QosPortPriorityRemoteA | read-write | current | Remote device Fiber 2 Qos Port Priority : 0:priority 0 1:priority 1 2:priority 2 3:priority 3 |
| 1.3.6.1.4.1.4756.20.191.40.1.161 | Columnf100ASUtp1QosPortPriorityRemoteA | read-write | current | Remote device Utp3 Qos Port Priority : 0:priority 0 1:priority 1 2:priority 2 3:priority 3 |
| 1.3.6.1.4.1.4756.20.191.40.1.162 | Columnf100ASUtp2QosPortPriorityRemoteA | read-write | current | Remote device Utp4 Qos Port Priority : 0:priority 0 1:priority 1 2:priority 2 3:priority 3 |
| 1.3.6.1.4.1.4756.20.191.40.1.163 | Columnf100ASSetDefaultRemoteA | read-write | current | Remote device Set to default: 0:Off 1:Action |
| 1.3.6.1.4.1.4756.20.192 | Nodef100ASRemoteBCards | |||
| 1.3.6.1.4.1.4756.20.192.40 | Tablef100ASRemoteBTable | not-accessible | current | A list of local frm220-100AS card entries. The number of entries is f100AS-NoRemoteB. |
| 1.3.6.1.4.1.4756.20.192.40.1 | Rowf100ASRemoteBEntry | not-accessible | current | An entry containing management information applicable to a particular local frm220-100AS card. |
| 1.3.6.1.4.1.4756.20.192.40.1.1 | Columnf100ASChassisIndexRemoteB | read-only | current | A unique value for each local card. It is the chassis location number. |
| 1.3.6.1.4.1.4756.20.192.40.1.2 | Columnf100ASSlotIndexRemoteB | read-only | current | A unique value for each local card. It is the slot location number. |
| 1.3.6.1.4.1.4756.20.192.40.1.3 | Columnf100ASCardHWVerRemoteB | read-only | current | Remote device card hardware version x.xxx |
| 1.3.6.1.4.1.4756.20.192.40.1.4 | Columnf100ASCardFWVerRemoteB | read-only | current | Remote device card firmware version x.xxx |
| 1.3.6.1.4.1.4756.20.192.40.1.5 | Columnf100ASCardCPLDVerRemoteB | read-only | current | Remote device card CPLD version x.xxx |
| 1.3.6.1.4.1.4756.20.192.40.1.6 | Columnf100ASCardFPGAVerRemoteB | read-only | current | Remote device card FPGA version x.xxx |
| 1.3.6.1.4.1.4756.20.192.40.1.7 | Columnf100ASModelRemoteB | read-only | current | Remote frm220 f100AS Serial Type |
| 1.3.6.1.4.1.4756.20.192.40.1.8 | Columnf100ASFx1LinkRemoteB | read-only | current | Remote device card fiber port 1 link status: 0:Down 1:Up |
| 1.3.6.1.4.1.4756.20.192.40.1.9 | Columnf100ASFx1OAMLoopedRemoteB | read-only | current | Remote device card fiber port 1 OAM looped: 0:Off 1:on |
| 1.3.6.1.4.1.4756.20.192.40.1.10 | Columnf100ASFx1LBTestRemoteB | read-write | current | Force remote device card to do fiber port 1 LoopBack testing: 0:Off 1:Action |
| 1.3.6.1.4.1.4756.20.192.40.1.11 | Columnf100ASFx1OAMRLBStatusRemoteB | read-only | current | Remote device card fiber port 1 LoopBack testing status: 0:Off 1:Ok 2:Fail |
| 1.3.6.1.4.1.4756.20.192.40.1.12 | Columnf100ASFx1RemoPwrAbRemoteB | read-only | current | Remote device card fiber port 1 Remote Power status: 0:Abnormal 1:OK 2:None |
| 1.3.6.1.4.1.4756.20.192.40.1.13 | Columnf100ASFx2LinkRemoteB | read-only | current | Remote device card fiber port 2 link status: 0:Down 1:Up |
| 1.3.6.1.4.1.4756.20.192.40.1.14 | Columnf100ASFx2OAMLoopedRemoteB | read-only | current | Remote device card fiber port 2 OAM looped: 0:Off 1:on |
| 1.3.6.1.4.1.4756.20.192.40.1.15 | Columnf100ASFx2LBTestRemoteB | read-write | current | Force remote device card to do fiber port 2 LoopBack testing: 0:Off 1:Action |
| 1.3.6.1.4.1.4756.20.192.40.1.16 | Columnf100ASFx2OAMRLBStatusRemoteB | read-only | current | Remote device card fiber port 1 LoopBack testing status: 0:Off 1:Ok 2:Fail |
| 1.3.6.1.4.1.4756.20.192.40.1.17 | Columnf100ASFx2RemoPwrAbRemoteB | read-only | current | Remote device card fiber port 2 Remote Power status: 0:Abnormal 1:OK 2:None |
| 1.3.6.1.4.1.4756.20.192.40.1.18 | Columnf100ASUtp1LinkRemoteB | read-only | current | Remote device card UTP port 3 link status: 0:Down 1:Up |
| 1.3.6.1.4.1.4756.20.192.40.1.19 | Columnf100ASUtp1NegoRemoteB | read-write | current | Remote device card UTP port 3 negotiation status: 0:Manual 1:Auto |
| 1.3.6.1.4.1.4756.20.192.40.1.20 | Columnf100ASUtp1SpeedRemoteB | read-write | current | Remote device card UTP port 3 speed setting: 0:10 Base-T 1:100 Base-TX |
| 1.3.6.1.4.1.4756.20.192.40.1.21 | Columnf100ASUtp1DuplexRemoteB | read-write | current | Remote device card UTP port 3 duplex setting: 0:Half duplex mode 1:Full duplex mode |
| 1.3.6.1.4.1.4756.20.192.40.1.22 | Columnf100ASUtp1SpeedStatusRemoteB | read-only | current | Remote device card UTP port 3 speed status: 0:10 Base-T 1:100 Base-TX |
| 1.3.6.1.4.1.4756.20.192.40.1.23 | Columnf100ASUtp1DuplexStatusRemoteB | read-only | current | Remote device card UTP port 3 duplex status: 0:Half duplex mode 1:Full duplex mode |
| 1.3.6.1.4.1.4756.20.192.40.1.24 | Columnf100ASUtp2LinkRemoteB | read-only | current | Remote device card UTP port 4 link status: 0:Down 1:Up |
| 1.3.6.1.4.1.4756.20.192.40.1.25 | Columnf100ASUtp2NegoRemoteB | read-write | current | Remote device card UTP port 4 negotiation status: 0:Manual 1:Auto |
| 1.3.6.1.4.1.4756.20.192.40.1.26 | Columnf100ASUtp2SpeedRemoteB | read-write | current | Remote device card UTP port 4 speed setting: 0:10 Base-T 1:100 Base-TX |
| 1.3.6.1.4.1.4756.20.192.40.1.27 | Columnf100ASUtp2DuplexRemoteB | read-write | current | Remote device card UTP port 2 duplex setting: 0:Half duplex mode 1:Full duplex mode |
| 1.3.6.1.4.1.4756.20.192.40.1.28 | Columnf100ASUtp2SpeedStatusRemoteB | read-only | current | Remote device card UTP port 4 speed status: 0:10 Base-T 1:100 Base-TX |
| 1.3.6.1.4.1.4756.20.192.40.1.29 | Columnf100ASUtp2DuplexStatusRemoteB | read-only | current | Remote device card UTP port 2 duplex status: 0:Half duplex mode 1:Full duplex mode |
| 1.3.6.1.4.1.4756.20.192.40.1.30 | Columnf100ASFx1IrlModeRemoteB | read-write | current | Remote device card port 1 Rate Limit mode: 0:unlimited 1:limited |
| 1.3.6.1.4.1.4756.20.192.40.1.31 | Columnf100ASFx1IrlIndexRemoteB | read-write | current | Remote device card port 1 Ingress Rate Limit index: Index Limit Rate 0 Disable 1 128K 2 256K 3 512K 4 1M 5 2M 6 4M 7 8M |
| 1.3.6.1.4.1.4756.20.192.40.1.32 | Columnf100ASFx1ErlIndexRemoteB | read-write | current | Remote device card port 1 Egress Rate Limit index: Index Limit Rate 0 Disable 1 128K 2 256K 3 512K 4 1M 5 2M 6 4M 7 8M |
| 1.3.6.1.4.1.4756.20.192.40.1.33 | Columnf100ASFx2IrlModeRemoteB | read-write | current | Remote device card port 2 Rate Limit mode: 0:unlimited 1:limited |
| 1.3.6.1.4.1.4756.20.192.40.1.34 | Columnf100ASFx2IrlIndexRemoteB | read-write | current | Remote device card port 2 Ingress Rate Limit index: Index Limit Rate 0 Disable 1 128K 2 256K 3 512K 4 1M 5 2M 6 4M 7 8M |
| 1.3.6.1.4.1.4756.20.192.40.1.35 | Columnf100ASFx2ErlIndexRemoteB | read-write | current | Remote device card port 2 Egress Rate Limit index: Index Limit Rate 0 Disable 1 128K 2 256K 3 512K 4 1M 5 2M 6 4M 7 8M |
| 1.3.6.1.4.1.4756.20.192.40.1.36 | Columnf100ASUtp1IrlModeRemoteB | read-write | current | Remote device card port 3 Rate Limit mode: 0:unlimited 1:limited |
| 1.3.6.1.4.1.4756.20.192.40.1.37 | Columnf100ASUtp1IrlIndexRemoteB | read-write | current | Remote device card port 3 Ingress Rate Limit index: Index Limit Rate 0 Disable 1 128K 2 256K 3 512K 4 1M 5 2M 6 4M 7 8M |
| 1.3.6.1.4.1.4756.20.192.40.1.38 | Columnf100ASUtp1ErlIndexRemoteB | read-write | current | Remote device card port 3 Egress Rate Limit index: Index Limit Rate 0 Disable 1 128K 2 256K 3 512K 4 1M 5 2M 6 4M 7 8M |
| 1.3.6.1.4.1.4756.20.192.40.1.39 | Columnf100ASUtp2IrlModeRemoteB | read-write | current | Remote device card port 4 Rate Limit mode: 0:unlimited 1:limited |
| 1.3.6.1.4.1.4756.20.192.40.1.40 | Columnf100ASUtp2IrlIndexRemoteB | read-write | current | Remote device card port 4 Ingress Rate Limit index: Index Limit Rate 0 Disable 1 128K 2 256K 3 512K 4 1M 5 2M 6 4M 7 8M |
| 1.3.6.1.4.1.4756.20.192.40.1.41 | Columnf100ASUtp2ErlIndexRemoteB | read-write | current | Remote device card port 4 Egress Rate Limit index: Index Limit Rate 0 Disable 1 128K 2 256K 3 512K 4 1M 5 2M 6 4M 7 8M |
| 1.3.6.1.4.1.4756.20.192.40.1.42 | Columnf100ASDeviceActiveRemoteB | read-only | current | Remote device card active mode: (It is read-only in local device.) 0:Disable 1:Enable |
| 1.3.6.1.4.1.4756.20.192.40.1.43 | Columnf100ASDeviceResetRemoteB | read-write | current | Force remote device card to reset mode: 0:Off 1:Action |
| 1.3.6.1.4.1.4756.20.192.40.1.44 | Columnf100ASFx1ActiveRemoteB | read-only | current | Remote device fiber port 1 active mode: 0:Disable 1:Enable |
| 1.3.6.1.4.1.4756.20.192.40.1.45 | Columnf100ASFx2ActiveRemoteB | read-only | current | Remote device fiber port 2 active mode: 0:Disable 1:Enable |
| 1.3.6.1.4.1.4756.20.192.40.1.46 | Columnf100ASUtp1ActiveRemoteB | read-write | current | Remote device UTP port 3 active mode: 0:Disable 1:Enable |
| 1.3.6.1.4.1.4756.20.192.40.1.47 | Columnf100ASUtp2ActiveRemoteB | read-write | current | Remote device UTP port 4 active mode: 0:Disable 1:Enable |
| 1.3.6.1.4.1.4756.20.192.40.1.48 | Columnf100ASOamChAModeRemoteB | read-write | current | Remote device OAM Channel A mode: 0:Passive 1:Active |
| 1.3.6.1.4.1.4756.20.192.40.1.49 | Columnf100ASOamChBModeRemoteB | read-write | current | Remote device OAM Channel B mode: 0:Passive 1:Active |
| 1.3.6.1.4.1.4756.20.192.40.1.50 | Columnf100ASOamMaxPDUsRemoteB | read-write | current | Remote device OAM max OAMPDU size: 60-1518 Octets |
| 1.3.6.1.4.1.4756.20.192.40.1.51 | Columnf100ASFx1AlsRemoteB | read-write | current | Remote device card port 1 Auto Laser Shutdown mode: 0:Disable 1:Enable |
| 1.3.6.1.4.1.4756.20.192.40.1.52 | Columnf100ASFx2AlsRemoteB | read-write | current | Remote device card port 2 Auto Laser Shutdown mode: 0:Disable 1:Enable |
| 1.3.6.1.4.1.4756.20.192.40.1.53 | Columnf100ASPauseFrameRemoteB | read-write | current | Remote device card pause frame mode: 0:Disable 1:Enable |
| 1.3.6.1.4.1.4756.20.192.40.1.54 | Columnf100ASFhrModeRemoteB | read-write | current | Remote device card accepts remote Fiber Hardware Reset mode: 0:Disable 1:Enable |
| 1.3.6.1.4.1.4756.20.192.40.1.55 | Columnf100ASFx1LLFDepLogiRemoteB | read-write | current | Remote device card port 1 Link Loss Forwarding depends boolean logic: 0:and 1:or |
| 1.3.6.1.4.1.4756.20.192.40.1.56 | Columnf100ASFx1LLFDepPort2RemoteB | read-write | current | Remote device card port 1 Link Loss Forwarding depends on port 2 Fiber Rx link: 0:don't care 1:selected |
| 1.3.6.1.4.1.4756.20.192.40.1.57 | Columnf100ASFx1LLFDepPort3RemoteB | read-write | current | Remote device card port 1 Link Loss Forwarding depends on port 3 Ethernet Rx link: 0:don't care 1:selected |
| 1.3.6.1.4.1.4756.20.192.40.1.58 | Columnf100ASFx1LLFDepPort4RemoteB | read-write | current | Remote device card port 1 Link Loss Forwarding depends on port 4 Ethernet Rx link: 0:don't care 1:selected |
| 1.3.6.1.4.1.4756.20.192.40.1.59 | Columnf100ASFx2LLFDepLogiRemoteB | read-write | current | Remote device card port 2 Link Loss Forwarding depends boolean logic: 0:and 1:or |
| 1.3.6.1.4.1.4756.20.192.40.1.60 | Columnf100ASFx2LLFDepPort1RemoteB | read-write | current | Remote device card port 2 Link Loss Forwarding depends on port 1 Fiber Rx link: 0:don't care 1:selected |
| 1.3.6.1.4.1.4756.20.192.40.1.61 | Columnf100ASFx2LLFDepPort3RemoteB | read-write | current | Remote device card port 2 Link Loss Forwarding depends on port 3 Ethernet Rx link: 0:don't care 1:selected |
| 1.3.6.1.4.1.4756.20.192.40.1.62 | Columnf100ASFx2LLFDepPort4RemoteB | read-write | current | Remote device card port 2 Link Loss Forwarding depends on port 4 Ethernet Rx link: 0:don't care 1:selected |
| 1.3.6.1.4.1.4756.20.192.40.1.63 | Columnf100ASUtp1LLFDepLogiRemoteB | read-write | current | Remote device card port 3 Link Loss Forwarding depends boolean logic: 0:and 1:or |
| 1.3.6.1.4.1.4756.20.192.40.1.64 | Columnf100ASUtp1LLFDepPort1RemoteB | read-write | current | Remote device card port 3 Link Loss Forwarding depends on port 1 Fiber Rx link: 0:don't care 1:selected |
| 1.3.6.1.4.1.4756.20.192.40.1.65 | Columnf100ASUtp1LLFDepPort2RemoteB | read-write | current | Remote device card port 3 Link Loss Forwarding depends on port 2 Fiber Rx link: 0:don't care 1:selected |
| 1.3.6.1.4.1.4756.20.192.40.1.66 | Columnf100ASUtp2LLFDepLogiRemoteB | read-write | current | Remote device card port 4 Link Loss Forwarding depends boolean logic: 0:and 1:or |
| 1.3.6.1.4.1.4756.20.192.40.1.67 | Columnf100ASUtp2LLFDepPort1RemoteB | read-write | current | Remote device card port 4 Link Loss Forwarding depends on port 1 Fiber Rx link: 0:don't care 1:selected |
| 1.3.6.1.4.1.4756.20.192.40.1.68 | Columnf100ASUtp2LLFDepPort2RemoteB | read-write | current | Remote device card port 4 Link Loss Forwarding depends on port 2 Fiber Rx link: 0:don't care 1:selected |
| 1.3.6.1.4.1.4756.20.192.40.1.69 | Columnf100ASAdvanceFunsRemoteB | read-write | current | Remote device card Switch functions mode: 0:Normal 2:Port 1&2 Mirror 3:Port VLAN 1/3;2/4 4:Port 1&2 Redundancy 5:Static 802.1Q VLAN 6:Spanning Tree protocol 7:… |
| 1.3.6.1.4.1.4756.20.192.40.1.70 | Columnf100ASFx1InfoROM1RemoteB | read-only | current | Remote device card port 1 INFORemoteOM information 1 valid: 0:Invalid 1:Valid |
| 1.3.6.1.4.1.4756.20.192.40.1.71 | Columnf100ASFx1InfoROM2RemoteB | read-only | current | Remote device card port 1 INFORemoteOM information 2 valid: 0:Invalid 1:Valid(replacing D/D function |
| 1.3.6.1.4.1.4756.20.192.40.1.72 | Columnf100ASFx2InfoROM1RemoteB | read-only | current | Remote device card port 2 INFORemoteOM information 1 valid: 0:Invalid 1:Valid |
| 1.3.6.1.4.1.4756.20.192.40.1.73 | Columnf100ASFx2InfoROM2RemoteB | read-only | current | Remote device card port 2 INFORemoteOM information 2 valid: 0:Invalid 1:Valid(replacing D/D function) |
| 1.3.6.1.4.1.4756.20.192.40.1.74 | Columnf100ASFx1InfoSN1RemoteB | read-only | current | Remote device card port 1 INFORemoteOM S/N 1 |
| 1.3.6.1.4.1.4756.20.192.40.1.75 | Columnf100ASFx1InfoSN2RemoteB | read-only | current | Remote device card port 1 INFORemoteOM S/N 2 |
| 1.3.6.1.4.1.4756.20.192.40.1.76 | Columnf100ASFx2InfoSN1RemoteB | read-only | current | Remote device card port 2 INFORemoteOM S/N 1 |
| 1.3.6.1.4.1.4756.20.192.40.1.77 | Columnf100ASFx2InfoSN2RemoteB | read-only | current | Remote device card port 2 INFORemoteOM S/N 2 |
| 1.3.6.1.4.1.4756.20.192.40.1.78 | Columnf100ASFx1DDRemoteB | read-only | current | Remote device card fiber port 1 Digital Diagnostic function: 0:No 1:Yes |
| 1.3.6.1.4.1.4756.20.192.40.1.79 | Columnf100ASFx1DDVendorRemoteB | read-only | current | Remote device card fiber port 1 D/D information: Vendor name |
| 1.3.6.1.4.1.4756.20.192.40.1.80 | Columnf100ASFx1DDPartNoRemoteB | read-only | current | Remote device card fiber port 1 D/D information: Vendor part number |
| 1.3.6.1.4.1.4756.20.192.40.1.81 | Columnf100ASFx1DDFiberTypeRemoteB | read-only | current | Remote device card fiber port 1 D/D information: Fiber Type |
| 1.3.6.1.4.1.4756.20.192.40.1.82 | Columnf100ASFx1DDWaveLenRemoteB | read-only | current | Remote device card fiber port 1 D/D information: Wave length |
| 1.3.6.1.4.1.4756.20.192.40.1.83 | Columnf100ASFx1DDWaveLen2RemoteB | read-only | current | Remote device card fiber port 1 D/D information: Wave length 2 |
| 1.3.6.1.4.1.4756.20.192.40.1.84 | Columnf100ASFx1DDLinkLenRemoteB | read-only | current | Remote device card fiber port 1 D/D information: Link length |
| 1.3.6.1.4.1.4756.20.192.40.1.85 | Columnf100ASFx1DDLenUnitRemoteB | read-only | current | Remote device card fiber port 1 D/D information: Length Unit |
| 1.3.6.1.4.1.4756.20.192.40.1.86 | Columnf100ASFx1DDStatusRemoteB | read-only | current | Remote device card fiber port 1 D/D information: Status Support |
| 1.3.6.1.4.1.4756.20.192.40.1.87 | Columnf100ASFx1DDRxSensRemoteB | read-only | current | Remote device card fiber port 1 D/D information: Rx Sensitivity |
| 1.3.6.1.4.1.4756.20.192.40.1.88 | Columnf100ASFx1DDTxPWRRemoteB | read-only | current | Remote device card fiber port 1 D/D information: Tx power |
| 1.3.6.1.4.1.4756.20.192.40.1.89 | Columnf100ASFx1DDRxPWRRemoteB | read-only | current | Remote device card fiber port 1 D/D information: Rx power |
| 1.3.6.1.4.1.4756.20.192.40.1.90 | Columnf100ASFx1DDTempRemoteB | read-only | current | Remote device card fiber port 1 D/D information: Temperature in degree C |
| 1.3.6.1.4.1.4756.20.192.40.1.91 | Columnf100ASFx1DDPWRMarginRemoteB | read-only | current | Remote device card fiber port 1 D/D information: Power margin |
| 1.3.6.1.4.1.4756.20.192.40.1.92 | Columnf100ASFx1DDPWRLossRemoteB | read-only | current | Remote device card fiber port 1 D/D information: Power loss |
| 1.3.6.1.4.1.4756.20.192.40.1.93 | Columnf100ASFx2DDRemoteB | read-only | current | Remote device card fiber port 2 Digital Diagnostic function: 0:No 1:Yes |
| 1.3.6.1.4.1.4756.20.192.40.1.94 | Columnf100ASFx2DDVendorRemoteB | read-only | current | Remote device card fiber port 2 D/D information: Vendor name |
| 1.3.6.1.4.1.4756.20.192.40.1.95 | Columnf100ASFx2DDPartNoRemoteB | read-only | current | Remote device card fiber port 2 D/D information: Vendor part number |
| 1.3.6.1.4.1.4756.20.192.40.1.96 | Columnf100ASFx2DDFiberTypeRemoteB | read-only | current | Remote device card fiber port 2 D/D information: Fiber Type |
| 1.3.6.1.4.1.4756.20.192.40.1.97 | Columnf100ASFx2DDWaveLenRemoteB | read-only | current | Remote device card fiber port 2 D/D information: Wave length |
| 1.3.6.1.4.1.4756.20.192.40.1.98 | Columnf100ASFx2DDWaveLen2RemoteB | read-only | current | Remote device card fiber port 2 D/D information: Wave length 2 |
| 1.3.6.1.4.1.4756.20.192.40.1.99 | Columnf100ASFx2DDLinkLenRemoteB | read-only | current | Remote device card fiber port 2 D/D information: Link length |
| 1.3.6.1.4.1.4756.20.192.40.1.100 | Columnf100ASFx2DDLenUnitRemoteB | read-only | current | Remote device card fiber port 2 D/D information: Length Unit |
| 1.3.6.1.4.1.4756.20.192.40.1.101 | Columnf100ASFx2DDStatusRemoteB | read-only | current | Remote device card fiber port 2 D/D information: Status Support |
| 1.3.6.1.4.1.4756.20.192.40.1.102 | Columnf100ASFx2DDRxSensRemoteB | read-only | current | Remote device card fiber port 2 D/D information: Rx Sensitivity |
| 1.3.6.1.4.1.4756.20.192.40.1.103 | Columnf100ASFx2DDTxPWRRemoteB | read-only | current | Remote device card fiber port 2 D/D information: Tx power |
| 1.3.6.1.4.1.4756.20.192.40.1.104 | Columnf100ASFx2DDRxPWRRemoteB | read-only | current | Remote device card fiber port 2 D/D information: Rx power |
| 1.3.6.1.4.1.4756.20.192.40.1.105 | Columnf100ASFx2DDTempRemoteB | read-only | current | Remote device card fiber port 2 D/D information: Temperature in degree C |
| 1.3.6.1.4.1.4756.20.192.40.1.106 | Columnf100ASFx2DDPWRMarginRemoteB | read-only | current | Remote device card fiber port 2 D/D information: Power margin |
| 1.3.6.1.4.1.4756.20.192.40.1.107 | Columnf100ASFx2DDPWRLossRemoteB | read-only | current | Remote device card fiber port 2 D/D information: Power loss |
| 1.3.6.1.4.1.4756.20.192.40.1.108 | Columnf100ASClrRMONCntsRemoteB | read-write | current | Clear local device card RMON IN/OUT counters: 0:No action 1:Action |
| 1.3.6.1.4.1.4756.20.192.40.1.109 | Columnf100ASFx1RMONInRemoteB | read-only | current | Remote device card port 1 RMON IN counter. |
| 1.3.6.1.4.1.4756.20.192.40.1.110 | Columnf100ASFx1RMONOutRemoteB | read-only | current | Remote device card port 1 RMON OUT counter. |
| 1.3.6.1.4.1.4756.20.192.40.1.111 | Columnf100ASFx2RMONInRemoteB | read-only | current | Remote device card port 2 RMON IN counter. |
| 1.3.6.1.4.1.4756.20.192.40.1.112 | Columnf100ASFx2RMONOutRemoteB | read-only | current | Remote device card port 2 RMON OUT counter. |
| 1.3.6.1.4.1.4756.20.192.40.1.113 | Columnf100ASUtp1RMONInRemoteB | read-only | current | Remote device card port 3 RMON IN counter. |
| 1.3.6.1.4.1.4756.20.192.40.1.114 | Columnf100ASUtp1RMONOutRemoteB | read-only | current | Remote device card port 3 RMON OUT counter. |
| 1.3.6.1.4.1.4756.20.192.40.1.115 | Columnf100ASUtp2RMONInRemoteB | read-only | current | Remote device card port 4 RMON IN counter. |
| 1.3.6.1.4.1.4756.20.192.40.1.116 | Columnf100ASUtp2RMONOutRemoteB | read-only | current | Remote device card port 4 RMON OUT counter. |
| 1.3.6.1.4.1.4756.20.192.40.1.117 | Columnf100ASClrOAMCntsRemoteB | read-write | current | Clear local device card OAM counters: 0:No action 1:Action |
| 1.3.6.1.4.1.4756.20.192.40.1.118 | Columnf100ASOamChATxRemoteB | read-only | current | Remote device OAM Channel A TX OAMPDU frame count |
| 1.3.6.1.4.1.4756.20.192.40.1.119 | Columnf100ASOamChARxRemoteB | read-only | current | Remote device OAM Channel A RX OAMPDU frame count |
| 1.3.6.1.4.1.4756.20.192.40.1.120 | Columnf100ASOamInfoChATxRemoteB | read-only | current | Remote device OAM Channel A TX Information OAMPDU frame count |
| 1.3.6.1.4.1.4756.20.192.40.1.121 | Columnf100ASOamInfoChARxRemoteB | read-only | current | Remote device OAM Channel A RX Information OAMPDU frame count |
| 1.3.6.1.4.1.4756.20.192.40.1.122 | Columnf100ASOamEventChATxRemoteB | read-only | current | Remote device OAM Channel A TX Event OAMPDU frame count |
| 1.3.6.1.4.1.4756.20.192.40.1.123 | Columnf100ASOamUniEvtChARxRemoteB | read-only | current | Remote device OAM Channel A RX Unique Event OAMPDU frame count |
| 1.3.6.1.4.1.4756.20.192.40.1.124 | Columnf100ASOamDupEvtChARxRemoteB | read-only | current | Remote device OAM Channel A RX Duplicate Event OAMPDU frame count |
| 1.3.6.1.4.1.4756.20.192.40.1.125 | Columnf100ASOamLbChATxRemoteB | read-only | current | Remote device OAM Channel A TX Loopback Control OAMPDU frame count |
| 1.3.6.1.4.1.4756.20.192.40.1.126 | Columnf100ASOamLbChARxRemoteB | read-only | current | Remote device OAM Channel A RX Loopback Control OAMPDU frame count |
| 1.3.6.1.4.1.4756.20.192.40.1.127 | Columnf100ASOamVarReqChATxRemoteB | read-only | current | Remote device OAM Channel A TX Variable Request OAMPDU frame count |
| 1.3.6.1.4.1.4756.20.192.40.1.128 | Columnf100ASOamVarReqChARxRemoteB | read-only | current | Remote device OAM Channel A RX Variable Request OAMPDU frame count |
| 1.3.6.1.4.1.4756.20.192.40.1.129 | Columnf100ASOamVarRspChATxRemoteB | read-only | current | Remote device OAM Channel A TX Variable Response OAMPDU frame count |
| 1.3.6.1.4.1.4756.20.192.40.1.130 | Columnf100ASOamVarRspChARxRemoteB | read-only | current | Remote device OAM Channel A RX Variable Response OAMPDU frame count |
| 1.3.6.1.4.1.4756.20.192.40.1.131 | Columnf100ASOamOuiChATxRemoteB | read-only | current | Remote device OAM Channel A TX OUI OAMPDU frame count |
| 1.3.6.1.4.1.4756.20.192.40.1.132 | Columnf100ASOamOuiChARxRemoteB | read-only | current | Remote device OAM Channel A RX OUI OAMPDU frame count |
| 1.3.6.1.4.1.4756.20.192.40.1.133 | Columnf100ASOamUnknowChARxRemoteB | read-only | current | Remote device OAM Channel A RX Unsupported OAMPDU frame count |
| 1.3.6.1.4.1.4756.20.192.40.1.134 | Columnf100ASOamChBTxRemoteB | read-only | current | Remote device OAM Channel B TX OAMPDU frame count |
| 1.3.6.1.4.1.4756.20.192.40.1.135 | Columnf100ASOamChBRxRemoteB | read-only | current | Remote device OAM Channel B RX OAMPDU frame count |
| 1.3.6.1.4.1.4756.20.192.40.1.136 | Columnf100ASOamInfoChBTxRemoteB | read-only | current | Remote device OAM Channel B TX Information OAMPDU frame count |
| 1.3.6.1.4.1.4756.20.192.40.1.137 | Columnf100ASOamInfoChBRxRemoteB | read-only | current | Remote device OAM Channel B RX Information OAMPDU frame count |
| 1.3.6.1.4.1.4756.20.192.40.1.138 | Columnf100ASOamEventChBTxRemoteB | read-only | current | Remote device OAM Channel B TX Event OAMPDU frame count |
| 1.3.6.1.4.1.4756.20.192.40.1.139 | Columnf100ASOamUniEvtChBRxRemoteB | read-only | current | Remote device OAM Channel B RX Unique Event OAMPDU frame count |
| 1.3.6.1.4.1.4756.20.192.40.1.140 | Columnf100ASOamDupEvtChBRxRemoteB | read-only | current | Remote device OAM Channel B RX Duplicate Event OAMPDU frame count |
| 1.3.6.1.4.1.4756.20.192.40.1.141 | Columnf100ASOamLbChBTxRemoteB | read-only | current | Remote device OAM Channel B TX Loopback Control OAMPDU frame count |
| 1.3.6.1.4.1.4756.20.192.40.1.142 | Columnf100ASOamLbChBRxRemoteB | read-only | current | Remote device OAM Channel B RX Loopback Control OAMPDU frame count |
| 1.3.6.1.4.1.4756.20.192.40.1.143 | Columnf100ASOamVarReqChBTxRemoteB | read-only | current | Remote device OAM Channel B TX Variable Request OAMPDU frame count |
| 1.3.6.1.4.1.4756.20.192.40.1.144 | Columnf100ASOamVarReqChBRxRemoteB | read-only | current | Remote device OAM Channel B RX Variable Request OAMPDU frame count |
| 1.3.6.1.4.1.4756.20.192.40.1.145 | Columnf100ASOamVarRspChBTxRemoteB | read-only | current | Remote device OAM Channel B TX Variable Response OAMPDU frame count |
| 1.3.6.1.4.1.4756.20.192.40.1.146 | Columnf100ASOamVarRspChBRxRemoteB | read-only | current | Remote device OAM Channel B RX Variable Response OAMPDU frame count |
| 1.3.6.1.4.1.4756.20.192.40.1.147 | Columnf100ASOamOuiChBTxRemoteB | read-only | current | Remote device OAM Channel B TX OUI OAMPDU frame count |
| 1.3.6.1.4.1.4756.20.192.40.1.148 | Columnf100ASOamOuiChBRxRemoteB | read-only | current | Remote device OAM Channel B RX OUI OAMPDU frame count |
| 1.3.6.1.4.1.4756.20.192.40.1.149 | Columnf100ASOamUnknowChBRxRemoteB | read-only | current | Remote device OAM Channel B RX Unsupported OAMPDU frame count |
| 1.3.6.1.4.1.4756.20.192.40.1.150 | Columnf100ASFx1FEFRemoteB | read-only | current | Remote card fiber1 detected Far End Fault: 0:Off 1:Detected |
| 1.3.6.1.4.1.4756.20.192.40.1.151 | Columnf100ASFx2FEFRemoteB | read-only | current | Remote card fiber2 detected Far End Fault: 0:Off 1:Detected |
| 1.3.6.1.4.1.4756.20.192.40.1.152 | Columnf100ASPower1RemoteB | read-only | current | Remote card OFC type power1 status: 0:Normal 1:Fail 2:None |
| 1.3.6.1.4.1.4756.20.192.40.1.153 | Columnf100ASPower2RemoteB | read-only | current | Remote card OFC type power2 status: 0:Normal 1:Fail 2:None |
| 1.3.6.1.4.1.4756.20.192.40.1.154 | Columnf100ASIpModeRemoteB | read-write | current | On Rack Ip Mode: 0:Enable 1:Disable |
| 1.3.6.1.4.1.4756.20.192.40.1.155 | Columnf100ASFx1QosPriorityRateRemoteB | read-write | current | Local device Fiber 1 Qos Priority Rate Mode: 0:Disable 1:Enable |
| 1.3.6.1.4.1.4756.20.192.40.1.156 | Columnf100ASFx2QosPriorityRateRemoteB | read-write | current | Local device Fiber 2 Qos Priority Rate Mode: 0:Disable 1:Enable |
| 1.3.6.1.4.1.4756.20.192.40.1.157 | Columnf100ASUtp1QosPriorityRateRemoteB | read-write | current | Remote device Utp 3 Qos Priority Rate Mode: 0:Disable 1:Enable |
| 1.3.6.1.4.1.4756.20.192.40.1.158 | Columnf100ASUtp2QosPriorityRateRemoteB | read-write | current | Remote device Utp 4 Qos Priority Rate Mode: 0:Disable 1:Enable |
| 1.3.6.1.4.1.4756.20.192.40.1.159 | Columnf100ASFx1QosPortPriorityRemoteB | read-write | current | Remote device Fiber 1 Qos Port Priority : 0:priority 0 1:priority 1 2:priority 2 3:priority 3 |
| 1.3.6.1.4.1.4756.20.192.40.1.160 | Columnf100ASFx2QosPortPriorityRemoteB | read-write | current | Remote device Fiber 2 Qos Port Priority : 0:priority 0 1:priority 1 2:priority 2 3:priority 3 |
| 1.3.6.1.4.1.4756.20.192.40.1.161 | Columnf100ASUtp1QosPortPriorityRemoteB | read-write | current | Remote device Utp3 Qos Port Priority : 0:priority 0 1:priority 1 2:priority 2 3:priority 3 |
| 1.3.6.1.4.1.4756.20.192.40.1.162 | Columnf100ASUtp2QosPortPriorityRemoteB | read-write | current | Remote device Utp4 Qos Port Priority : 0:priority 0 1:priority 1 2:priority 2 3:priority 3 |
| 1.3.6.1.4.1.4756.20.192.40.1.163 | Columnf100ASSetDefaultRemoteB | read-write | current | Local device Set to default: 0:Off 1:Action |
| 1.3.6.1.4.1.4756.20.200 | NodefMDCards | |||
| 1.3.6.1.4.1.4756.20.200.20 | TablefMDTable | not-accessible | current | A list of local FRM220-MUX/DEMUX card entries. The number of entries is fMD cards. |
| 1.3.6.1.4.1.4756.20.200.20.1 | RowfMDEntry | not-accessible | current | An entry containing management information applicable to a particular local FRM220-MUX/DEMUX card. |
| 1.3.6.1.4.1.4756.20.200.20.1.1 | ColumnfMDChassisIndex | read-only | current | A unique value for each local card. It is the chassis location number. |
| 1.3.6.1.4.1.4756.20.200.20.1.2 | ColumnfMDSlotIndex | read-only | current | A unique value for each local card. It is the slot location number. |
| 1.3.6.1.4.1.4756.20.200.20.1.3 | ColumnfMDCardHWVer | read-only | current | Local FRM220-3R27G card hardware version x.xxx |
| 1.3.6.1.4.1.4756.20.200.20.1.4 | ColumnfMDCardFWVer | read-only | current | Local FRM220-3R27G card firmware version x.xxx |
| 1.3.6.1.4.1.4756.20.200.20.1.5 | ColumnfMDCardCPLDVer | read-only | current | Local FRM220-3R27G card CPLD version x.xxx |
| 1.3.6.1.4.1.4756.20.200.20.1.6 | ColumnfMDCardFPGAVer | read-only | current | Local FRM220-3R27G card FPGA version x.xxx |
| 1.3.6.1.4.1.4756.20.200.20.1.7 | ColumnfMDModel | read-only | current | Local CardType: 0:CWMD40-KLMN 1:FRM220-MD40-UP02 2:CWMD82-IJKLMNOP 3:CWMD40-MNOP 4:CWMD80-IJKLMNOP 5:CWMD40B-JLNP 6:CWMD40A-IKMO 11:CWMD41A-IKMO 12:CWMD41B-JLN… |
| 1.3.6.1.4.1.4756.20.200.20.1.8 | ColumnfMDOpNum | read-only | current | Number of Optical Information: |
| 1.3.6.1.4.1.4756.20.200.20.1.9 | ColumnfMDUpgradeNum | read-only | current | Number of Upgrade Channel: |
| 1.3.6.1.4.1.4756.20.200.20.1.10 | ColumnfMDMonitorPort | read-only | current | Local FRM220-MUX/DEMUX monitor port |
| 1.3.6.1.4.1.4756.20.200.20.1.11 | ColumnfMDWaveLen1 | read-only | current | Local FRM220-MUX/DEMUX card WaveLen 1 |
| 1.3.6.1.4.1.4756.20.200.20.1.12 | ColumnfMDWaveLen2 | read-only | current | Local FRM220-MUX/DEMUX card WaveLen 2 |
| 1.3.6.1.4.1.4756.20.200.20.1.13 | ColumnfMDWaveLen3 | read-only | current | Local FRM220-MUX/DEMUX card WaveLen 3 |
| 1.3.6.1.4.1.4756.20.200.20.1.14 | ColumnfMDWaveLen4 | read-only | current | Local FRM220-MUX/DEMUX card WaveLen 4 |
| 1.3.6.1.4.1.4756.20.200.20.1.15 | ColumnfMDWaveLen5 | read-only | current | Local FRM220-MUX/DEMUX card WaveLen 5 |
| 1.3.6.1.4.1.4756.20.200.20.1.16 | ColumnfMDWaveLen6 | read-only | current | Local FRM220-MUX/DEMUX card WaveLen 6 |
| 1.3.6.1.4.1.4756.20.200.20.1.17 | ColumnfMDWaveLen7 | read-only | current | Local FRM220-MUX/DEMUX card WaveLen 7 |
| 1.3.6.1.4.1.4756.20.200.20.1.18 | ColumnfMDWaveLen8 | read-only | current | Local FRM220-MUX/DEMUX card WaveLen 8 |
| 1.3.6.1.4.1.4756.20.200.20.1.19 | ColumnfMDWaveLen9 | read-only | current | Local FRM220-MUX/DEMUX card WaveLen 9 |
| 1.3.6.1.4.1.4756.20.200.20.1.20 | ColumnfMDWaveLen10 | read-only | current | Local FRM220-MUX/DEMUX card WaveLen 10 |
| 1.3.6.1.4.1.4756.20.200.20.1.21 | ColumnfMDWaveLen11 | read-only | current | Local FRM220-MUX/DEMUX card WaveLen 11 |
| 1.3.6.1.4.1.4756.20.200.20.1.22 | ColumnfMDWaveLen12 | read-only | current | Local FRM220-MUX/DEMUX card WaveLen 12 |
| 1.3.6.1.4.1.4756.20.200.20.1.23 | ColumnfMDWaveLen13 | read-only | current | Local FRM220-MUX/DEMUX card WaveLen 13 |
| 1.3.6.1.4.1.4756.20.200.20.1.24 | ColumnfMDWaveLen14 | read-only | current | Local FRM220-MUX/DEMUX card WaveLen 14 |
| 1.3.6.1.4.1.4756.20.200.20.1.25 | ColumnfMDWaveLen15 | read-only | current | Local FRM220-MUX/DEMUX card WaveLen 15 |
| 1.3.6.1.4.1.4756.20.200.20.1.26 | ColumnfMDWaveLen16 | read-only | current | Local FRM220-MUX/DEMUX card WaveLen 16 |
| 1.3.6.1.4.1.4756.20.200.20.1.27 | ColumnfMDRxWaveLen1 | read-only | current | Local FRM220-MUX/DEMUX card RxWaveLen 1 |
| 1.3.6.1.4.1.4756.20.200.20.1.28 | ColumnfMDRxWaveLen2 | read-only | current | Local FRM220-MUX/DEMUX card RxWaveLen 2 |
| 1.3.6.1.4.1.4756.20.200.20.1.29 | ColumnfMDRxWaveLen3 | read-only | current | Local FRM220-MUX/DEMUX card RxWaveLen 3 |
| 1.3.6.1.4.1.4756.20.200.20.1.30 | ColumnfMDRxWaveLen4 | read-only | current | Local FRM220-MUX/DEMUX card RxWaveLen 4 |
| 1.3.6.1.4.1.4756.20.200.20.1.31 | ColumnfMDRxWaveLen5 | read-only | current | Local FRM220-MUX/DEMUX card RxWaveLen 5 |
| 1.3.6.1.4.1.4756.20.200.20.1.32 | ColumnfMDRxWaveLen6 | read-only | current | Local FRM220-MUX/DEMUX card RxWaveLen 6 |
| 1.3.6.1.4.1.4756.20.200.20.1.33 | ColumnfMDRxWaveLen7 | read-only | current | Local FRM220-MUX/DEMUX card RxWaveLen 7 |
| 1.3.6.1.4.1.4756.20.200.20.1.34 | ColumnfMDRxWaveLen8 | read-only | current | Local FRM220-MUX/DEMUX card RxWaveLen 8 |
| 1.3.6.1.4.1.4756.20.200.20.1.35 | ColumnfMDRxWaveLen9 | read-only | current | Local FRM220-MUX/DEMUX card RxWaveLen 9 |
| 1.3.6.1.4.1.4756.20.200.20.1.36 | ColumnfMDRxWaveLen10 | read-only | current | Local FRM220-MUX/DEMUX card RxWaveLen 10 |
| 1.3.6.1.4.1.4756.20.200.20.1.37 | ColumnfMDRxWaveLen11 | read-only | current | Local FRM220-MUX/DEMUX card RxWaveLen 11 |
| 1.3.6.1.4.1.4756.20.200.20.1.38 | ColumnfMDRxWaveLen12 | read-only | current | Local FRM220-MUX/DEMUX card RxWaveLen 12 |
| 1.3.6.1.4.1.4756.20.200.20.1.39 | ColumnfMDRxWaveLen13 | read-only | current | Local FRM220-MUX/DEMUX card RxWaveLen 13 |
| 1.3.6.1.4.1.4756.20.200.20.1.40 | ColumnfMDRxWaveLen14 | read-only | current | Local FRM220-MUX/DEMUX card RxWaveLen 14 |
| 1.3.6.1.4.1.4756.20.200.20.1.41 | ColumnfMDRxWaveLen15 | read-only | current | Local FRM220-MUX/DEMUX card RxWaveLen 15 |
| 1.3.6.1.4.1.4756.20.200.20.1.42 | ColumnfMDRxWaveLen16 | read-only | current | Local FRM220-MUX/DEMUX card RxWaveLen 16 |
| 1.3.6.1.4.1.4756.20.200.20.1.43 | ColumnfMDChannel1Start | read-only | current | Local FRM220-MUX/DEMUX card upgrade channel 1 information |
| 1.3.6.1.4.1.4756.20.200.20.1.44 | ColumnfMDChannel1End | read-only | current | Local FRM220-MUX/DEMUX card upgrade channel information |
| 1.3.6.1.4.1.4756.20.200.20.1.45 | ColumnfMDChannel2Start | read-only | current | Local FRM220-MUX/DEMUX card upgrade channel 2 information |
| 1.3.6.1.4.1.4756.20.200.20.1.46 | ColumnfMDChannel2End | read-only | current | Local FRM220-MUX/DEMUX card upgrade channe 2 information |
| 1.3.6.1.4.1.4756.20.200.20.1.47 | ColumnfMDChannel3Start | read-only | current | Local FRM220-MUX/DEMUX card upgrade channel 3 information |
| 1.3.6.1.4.1.4756.20.200.20.1.48 | ColumnfMDChannel3End | read-only | current | Local FRM220-MUX/DEMUX card upgrade channe 3 information |
| 1.3.6.1.4.1.4756.20.200.20.1.49 | ColumnfMDChannel4Start | read-only | current | Local FRM220-MUX/DEMUX card upgrade channel 4 information |
| 1.3.6.1.4.1.4756.20.200.20.1.50 | ColumnfMDChannel4End | read-only | current | Local FRM220-MUX/DEMUX card upgrade channe 4 information |
| 1.3.6.1.4.1.4756.20.200.20.1.51 | ColumnfMDChannel5Start | read-only | current | Local FRM220-MUX/DEMUX card upgrade channel 5 information |
| 1.3.6.1.4.1.4756.20.200.20.1.52 | ColumnfMDChannel5End | read-only | current | Local FRM220-MUX/DEMUX card upgrade channe 5 information |
| 1.3.6.1.4.1.4756.20.200.20.1.53 | ColumnfMDChannel6Start | read-only | current | Local FRM220-MUX/DEMUX card upgrade channel 6 information |
| 1.3.6.1.4.1.4756.20.200.20.1.54 | ColumnfMDChannel6End | read-only | current | Local FRM220-MUX/DEMUX card upgrade channe 6 information |
| 1.3.6.1.4.1.4756.20.200.20.1.55 | ColumnfMDChannel7Start | read-only | current | Local FRM220-MUX/DEMUX card upgrade channel 7 information |
| 1.3.6.1.4.1.4756.20.200.20.1.56 | ColumnfMDChannel7End | read-only | current | Local FRM220-MUX/DEMUX card upgrade channe 7 information |
| 1.3.6.1.4.1.4756.20.200.20.1.57 | ColumnfMDChannel8Start | read-only | current | Local FRM220-MUX/DEMUX card upgrade channel 8 information |
| 1.3.6.1.4.1.4756.20.200.20.1.58 | ColumnfMDChannel8End | read-only | current | Local FRM220-MUX/DEMUX card upgrade channe 8 information |
| 1.3.6.1.4.1.4756.20.210 | Nodef3R10GCards | |||
| 1.3.6.1.4.1.4756.20.210.20 | Tablef3R10GTable | not-accessible | current | A list of local FRM220-3R10G card entries. The number of entries is f3R10G-No-L. |
| 1.3.6.1.4.1.4756.20.210.20.1 | Rowf3R10GEntry | not-accessible | current | An entry containing management information applicable to a particular local FRM220-3R10G card. |
| 1.3.6.1.4.1.4756.20.210.20.1.1 | Columnf3R10GChassisIndex | read-only | current | A unique value for each local card. It is the chassis location number. |
| 1.3.6.1.4.1.4756.20.210.20.1.2 | Columnf3R10GSlotIndex | read-only | current | A unique value for each local card. It is the slot location number. |
| 1.3.6.1.4.1.4756.20.210.20.1.3 | Columnf3R10GCardHWVer | read-only | current | Local FRM220-3R10G card hardware version x.xxx |
| 1.3.6.1.4.1.4756.20.210.20.1.4 | Columnf3R10GCardFWVer | read-only | current | Local FRM220-3R10G card firmware version x.xxx |
| 1.3.6.1.4.1.4756.20.210.20.1.5 | Columnf3R10GCardCPLDVer | read-only | current | Local FRM220-3R10G card CPLD version x.xxx |
| 1.3.6.1.4.1.4756.20.210.20.1.6 | Columnf3R10GCardFPGAVer | read-only | current | Local FRM220-3R10G card FPGA version x.xxx |
| 1.3.6.1.4.1.4756.20.210.20.1.7 | Columnf3R10GModel | read-only | current | Local CardType: 0:FRM220-3R10G/SS 1:FRM220-3R10G/SX 2:FRM220-3R10G/XX |
| 1.3.6.1.4.1.4756.20.210.20.1.8 | Columnf3R10GDeviceActive | read-write | current | Local FRM220-3R10G card active: 0:Inactive 1:Active |
| 1.3.6.1.4.1.4756.20.210.20.1.9 | Columnf3R10GFx1Link | read-only | current | Local FRM220-3R10G card Fiber1 link status: 0:Down 1:Up |
| 1.3.6.1.4.1.4756.20.210.20.1.10 | Columnf3R10GFx2Link | read-only | current | Local FRM220-3R10G card Fiber2 link status: 0:Down 1:Up |
| 1.3.6.1.4.1.4756.20.210.20.1.11 | Columnf3R10GFx1CRDLocked | read-only | current | Local FRM220-3R10G card Fiber1 CRD Locked: 0:Not Locked 1:Locked |
| 1.3.6.1.4.1.4756.20.210.20.1.12 | Columnf3R10GFx2CRDLocked | read-only | current | Local FRM220-3R10G card Fiber2 CRD Locked: 0:Not Locked 1:Locked |
| 1.3.6.1.4.1.4756.20.210.20.1.13 | Columnf3R10GFx1LossPropagation | read-write | current | Local FRM220-3R10G card Fiber1 Loss Propagation: 0:Disable 1:Enable |
| 1.3.6.1.4.1.4756.20.210.20.1.14 | Columnf3R10GFx2LossPropagation | read-write | current | Local FRM220-3R10G card Fiber2 Loss Propagation: 0:Disable 1:Enable |
| 1.3.6.1.4.1.4756.20.210.20.1.15 | Columnf3R10GFx1AlsMode | read-write | current | Local FRM220-3R10G card Fiber1 Auto Laser Showdown: 0:Disable 1:Enable |
| 1.3.6.1.4.1.4756.20.210.20.1.16 | Columnf3R10GFx2AlsMode | read-write | current | Local FRM220-3R10G card Fiber2 Auto Laser Showdown: 0:Disable 1:Enable |
| 1.3.6.1.4.1.4756.20.210.20.1.17 | Columnf3R10GPortReset | read-write | current | Force local FRM220-3R10G card to reset mode: 0:Off 1:Action |
| 1.3.6.1.4.1.4756.20.210.20.1.18 | Columnf3R10GSetDefault | read-write | current | Local FRM220-3R10G card set to default : 0:Off 1:Action |
| 1.3.6.1.4.1.4756.20.210.20.1.19 | Columnf3R10GSystemOK | read-only | current | Local FRM220-3R10G card system status: 0:Failure 1:Ok |
| 1.3.6.1.4.1.4756.20.210.20.1.20 | Columnf3R10GFx1Lbsetting | read-write | current | Local FRM220-3R10G card Fiber1 Loopback: 0:Off 1:On |
| 1.3.6.1.4.1.4756.20.210.20.1.21 | Columnf3R10GFx2Lbsetting | read-write | current | Local FRM220-3R10G card Fiber1 Loopback: 0:Off 1:On |
| 1.3.6.1.4.1.4756.20.210.20.1.22 | Columnf3R10GLbEnable | read-write | current | Local FRM220-3R10G card Loopback mode: 0:Disable 1:Enable |
| 1.3.6.1.4.1.4756.20.210.20.1.23 | Columnf3R10GBaudRate | read-write | current | Local FRM220-3R10G card BaudRate: 0:10G Ethernet 1:10G Fiber Channel 2:OC-192/STM-64 3:G.709 OTU2 4:1G Fiber Channel 5:2G Fiber Channel 6:4G Fiber Channel 7:8G… |
| 1.3.6.1.4.1.4756.20.210.20.1.24 | Columnf3R10GFx1TxFail | read-only | current | Local FRM220-3R10G card Fx1 transceiver Tx detect 0:Normal 1:Fail |
| 1.3.6.1.4.1.4756.20.210.20.1.25 | Columnf3R10GFx2TxFail | read-only | current | Local FRM220-3R10G card Fx2 transceiver Tx detect 0:Normal 1:Fail |
| 1.3.6.1.4.1.4756.20.210.20.1.26 | Columnf3R10GFx1DD | read-only | current | Local FRM220-3R10G card fiber Digital Diagnostic function: 0:No 1:Yes |
| 1.3.6.1.4.1.4756.20.210.20.1.27 | Columnf3R10GFx1DDVendor | read-only | current | Local FRM220-3R10G card fiber D/D information: Vendor name |
| 1.3.6.1.4.1.4756.20.210.20.1.28 | Columnf3R10GFx1DDPartNo | read-only | current | Local FRM220-3R10G card fiber D/D information: Vendor part number |
| 1.3.6.1.4.1.4756.20.210.20.1.29 | Columnf3R10GFx1DDFiberType | read-only | current | Local FRM220-3R10G card fiber D/D information: Fiber Type |
| 1.3.6.1.4.1.4756.20.210.20.1.30 | Columnf3R10GFx1DDWaveLen | read-only | current | Local FRM220-3R10G card fiber D/D information: Wave length |
| 1.3.6.1.4.1.4756.20.210.20.1.31 | Columnf3R10GFx1DDWaveLen2 | read-only | current | Local FRM220-3R10G card fiber D/D information: Wave length 2 |
| 1.3.6.1.4.1.4756.20.210.20.1.32 | Columnf3R10GFx1DDLinkLen | read-only | current | Local FRM220-3R10G card fiber D/D information: Link length |
| 1.3.6.1.4.1.4756.20.210.20.1.33 | Columnf3R10GFx1DDLenUnit | read-only | current | Local FRM220-3R10G card fiber D/D information: Length Unit |
| 1.3.6.1.4.1.4756.20.210.20.1.34 | Columnf3R10GFx1DDStatus | read-only | current | Local FRM220-3R10G card fiber D/D information: Status Support |
| 1.3.6.1.4.1.4756.20.210.20.1.35 | Columnf3R10GFx1DDRxSens | read-only | current | Local FRM220-3R10G card fiber D/D information: Rx Sensitivity |
| 1.3.6.1.4.1.4756.20.210.20.1.36 | Columnf3R10GFx1DDTxPWR | read-only | current | Local FRM220-3R10G card fiber D/D information: Tx power |
| 1.3.6.1.4.1.4756.20.210.20.1.37 | Columnf3R10GFx1DDRxPWR | read-only | current | Local FRM220-3R10G card fiber D/D information: Rx power |
| 1.3.6.1.4.1.4756.20.210.20.1.38 | Columnf3R10GFx1DDTemp | read-only | current | Local FRM220-3R10G card fiber D/D information: Temperature in degree C |
| 1.3.6.1.4.1.4756.20.210.20.1.39 | Columnf3R10GFx1DDPWRMargin | read-only | current | Local FRM220-3R10G card fiber D/D information: Power margin |
| 1.3.6.1.4.1.4756.20.210.20.1.40 | Columnf3R10GFx2DD | read-only | current | Local FRM220-3R10G card fiber2 Digital Diagnostic function: 0:No 1:Yes |
| 1.3.6.1.4.1.4756.20.210.20.1.41 | Columnf3R10GFx2DDVendor | read-only | current | Local FRM220-3R10G card fiber2 D/D information: Vendor name |
| 1.3.6.1.4.1.4756.20.210.20.1.42 | Columnf3R10GFx2DDPartNo | read-only | current | Local FRM220-3R10G card fiber2 D/D information: Vendor part number |
| 1.3.6.1.4.1.4756.20.210.20.1.43 | Columnf3R10GFx2DDFiberType | read-only | current | Local FRM220-3R10G card fiber2 D/D information: Fiber Type |
| 1.3.6.1.4.1.4756.20.210.20.1.44 | Columnf3R10GFx2DDWaveLen | read-only | current | Local FRM220-3R10G card fiber2 D/D information: Wave length |
| 1.3.6.1.4.1.4756.20.210.20.1.45 | Columnf3R10GFx2DDWaveLen2 | read-only | current | Local FRM220-3R10G card fiber2 D/D information: Wave length 2 |
| 1.3.6.1.4.1.4756.20.210.20.1.46 | Columnf3R10GFx2DDLinkLen | read-only | current | Local FRM220-3R10G card fiber2 D/D information: Link length |
| 1.3.6.1.4.1.4756.20.210.20.1.47 | Columnf3R10GFx2DDLenUnit | read-only | current | Local FRM220-3R10G card fiber2 D/D information: Length Unit |
| 1.3.6.1.4.1.4756.20.210.20.1.48 | Columnf3R10GFx2DDStatus | read-only | current | Local FRM220-3R10G card fiber2 D/D information: Status Support |
| 1.3.6.1.4.1.4756.20.210.20.1.49 | Columnf3R10GFx2DDRxSens | read-only | current | Local FRM220-3R10G card fiber2 D/D information: Rx Sensitivity |
| 1.3.6.1.4.1.4756.20.210.20.1.50 | Columnf3R10GFx2DDTxPWR | read-only | current | Local FRM220-3R10G card fiber2 D/D information: Tx power |
| 1.3.6.1.4.1.4756.20.210.20.1.51 | Columnf3R10GFx2DDRxPWR | read-only | current | Local FRM220-3R10G card fiber2 D/D information: Rx power |
| 1.3.6.1.4.1.4756.20.210.20.1.52 | Columnf3R10GFx2DDTemp | read-only | current | Local FRM220-3R10G card fiber2 D/D information: Temperature in degree C |
| 1.3.6.1.4.1.4756.20.210.20.1.53 | Columnf3R10GFx2DDPWRMargin | read-only | current | Local FRM220-3R10G card fiber2 D/D information: Power margin |
| 1.3.6.1.4.1.4756.20.220 | NodefE1DATALocalCards | |||
| 1.3.6.1.4.1.4756.20.220.20 | TablefE1DATALocalTable | not-accessible | current | A list of local FRM220-E1/DATA series card entries. The number of entries is fE1DATA-No-L. |
| 1.3.6.1.4.1.4756.20.220.20.1 | RowfE1DATALocalEntry | not-accessible | current | An entry containing management information applicable to a particular local FRM220-E1/DATA series card. |
| 1.3.6.1.4.1.4756.20.220.20.1.1 | ColumnfE1DATAChassisIndexLocal | read-only | current | A unique value for each local card. It is the chassis location number. |
| 1.3.6.1.4.1.4756.20.220.20.1.2 | ColumnfE1DATASlotIndexLocal | read-only | current | A unique value for each local card. It is the slot location number. |
| 1.3.6.1.4.1.4756.20.220.20.1.3 | ColumnfE1DATACardHWVerLocal | read-only | current | Local FRM220-E1DATA Series card hardware version x.xxx |
| 1.3.6.1.4.1.4756.20.220.20.1.4 | ColumnfE1DATACardFWVerLocal | read-only | current | Local FRM220-E1DATA Series card firmware version x.xxx |
| 1.3.6.1.4.1.4756.20.220.20.1.5 | ColumnfE1DATACardCPLDVerLocal | read-only | current | Local FRM220-E1DATA Series card CPLD version x.xxx |
| 1.3.6.1.4.1.4756.20.220.20.1.6 | ColumnfE1DATACardFPGAVerLocal | read-only | current | Local FRM220-E1DATA Series card FPGA version x.xxx |
| 1.3.6.1.4.1.4756.20.220.20.1.7 | ColumnfE1DATAPortActiveLocal | read-write | current | Local FRM220-E1DATA Series card active: 0:Disable 1:Enable |
| 1.3.6.1.4.1.4756.20.220.20.1.8 | ColumnfE1DATAPortResetLocal | read-write | current | Local FRM220-E1DATA Series card portreset: 0:OFF 1:Action |
| 1.3.6.1.4.1.4756.20.220.20.1.9 | ColumnfE1DATASettoDefaultLocal | read-write | current | Local FRM220-E1DATA Series card set to default: 0:OFF 1:Action |
| 1.3.6.1.4.1.4756.20.220.20.1.10 | ColumnfE1DATASignalLocal | read-only | current | Local FRM220-E1DATA Series card E1 signal status: 0:Signal Loss 1:Normal |
| 1.3.6.1.4.1.4756.20.220.20.1.11 | ColumnfE1DATASyncLocal | read-only | current | Local FRM220-E1DATA Series card E1 sync status: 0:Sync Loss 1:Normal |
| 1.3.6.1.4.1.4756.20.220.20.1.12 | ColumnfE1DATAReAisLocal | read-only | current | Local FRM220-E1DATA Series card E1 receive AIS: 0:NO 1:Have |
| 1.3.6.1.4.1.4756.20.220.20.1.13 | ColumnfE1DATAE1AlarmLocal | read-only | current | Local FRM220-E1DATA Series card E1 alarm: 0:NO 1:Have |
| 1.3.6.1.4.1.4756.20.220.20.1.14 | ColumnfE1DATALOMFLocal | read-only | current | Local FRM220-E1DATA Series card E1 loss of multiframe sync: 0:NO 1:Have |
| 1.3.6.1.4.1.4756.20.220.20.1.15 | ColumnfE1DATALinecodeViolationLocal | read-only | current | Local FRM220-E1DATA Series card E1 line code violation: 0:NO 1:Have |
| 1.3.6.1.4.1.4756.20.220.20.1.16 | ColumnfE1DATAConnectorLocal | read-only | current | Local FRM220-E1DATA Series card connector type: 0:BNC 1:RJ-48C |
| 1.3.6.1.4.1.4756.20.220.20.1.17 | ColumnfE1DATARdSTSLocal | read-only | current | Local FRM220-E1DATA Series card RD status: 0:ON 1:OFF 2:Flash |
| 1.3.6.1.4.1.4756.20.220.20.1.18 | ColumnfE1DATATdSTSLocal | read-only | current | Local FRM220-E1DATA Series card TD status: 0:ON 1:OFF 2:Flash |
| 1.3.6.1.4.1.4756.20.220.20.1.19 | ColumnfE1DATARtsSTSLocal | read-only | current | Local FRM220-E1DATA Series card RTS status: 0:On 1:Off |
| 1.3.6.1.4.1.4756.20.220.20.1.20 | ColumnfE1DATACtsSTSLocal | read-only | current | Local FRM220-E1DATA Series card CTS status: 0:On 1:Off |
| 1.3.6.1.4.1.4756.20.220.20.1.21 | ColumnfE1DATADcdSTSLocal | read-only | current | Local FRM220-E1DATA Series card DCD status: 0:On 1:Off |
| 1.3.6.1.4.1.4756.20.220.20.1.22 | ColumnfE1DATADsrSTSLocal | read-only | current | Local FRM220-E1DATA Series card DSR status: 0:On 1:Off |
| 1.3.6.1.4.1.4756.20.220.20.1.23 | ColumnfE1DATADtrSTSLocal | read-only | current | Local FRM220-E1DATA Series card DTR status: 0:On 1:Off |
| 1.3.6.1.4.1.4756.20.220.20.1.24 | ColumnfE1DATARemoPwAbLocal | read-only | current | Local FRM220-E1DATA Series card remote power fail : 0:Normal 1:Fail |
| 1.3.6.1.4.1.4756.20.220.20.1.25 | ColumnfE1DATABertErrLocal | read-only | current | Local FRM220-E1DATA Series card bert error : 0:No error 1:Have error |
| 1.3.6.1.4.1.4756.20.220.20.1.26 | ColumnfE1DATACableAdaptedSTSLocal | read-only | current | Local FRM220-E1DATA Series card cable adapted status: 4:RS-530 DTE 5:RS-530 DCE 6:X.21 DTE 7:X.21 DCE 8:V.35 DTE 9:V.35 DCE 10:RS-499 DTE 11:RS-449 DCE 12:RS-2… |
| 1.3.6.1.4.1.4756.20.220.20.1.27 | ColumnfE1DATAFrameLocal | read-write | current | Local FRM220-E1DATA Series card frame mode: 0:Unframed 1:Framed |
| 1.3.6.1.4.1.4756.20.220.20.1.28 | ColumnfE1DATATimeSlot1Local | read-write | current | Local FRM220-E1DATA Series card timeslot1: 0:Inactive 1:Active |
| 1.3.6.1.4.1.4756.20.220.20.1.29 | ColumnfE1DATATimeSlot2Local | read-write | current | Local FRM220-E1DATA Series card timeslot2: 0:Inactive 1:Active |
| 1.3.6.1.4.1.4756.20.220.20.1.30 | ColumnfE1DATATimeSlot3Local | read-write | current | Local FRM220-E1DATA Series card timeslot3: 0:Inactive 1:Active |
| 1.3.6.1.4.1.4756.20.220.20.1.31 | ColumnfE1DATATimeSlot4Local | read-write | current | Local FRM220-E1DATA Series card timeslot4: 0:Inactive 1:Active |
| 1.3.6.1.4.1.4756.20.220.20.1.32 | ColumnfE1DATATimeSlot5Local | read-write | current | Local FRM220-E1DATA Series card timeslot5: 0:Inactive 1:Active |
| 1.3.6.1.4.1.4756.20.220.20.1.33 | ColumnfE1DATATimeSlot6Local | read-write | current | Local FRM220-E1DATA Series card timeslot6: 0:Inactive 1:Active |
| 1.3.6.1.4.1.4756.20.220.20.1.34 | ColumnfE1DATATimeSlot7Local | read-write | current | Local FRM220-E1DATA Series card timeslot7: 0:Inactive 1:Active |
| 1.3.6.1.4.1.4756.20.220.20.1.35 | ColumnfE1DATATimeSlot8Local | read-write | current | Local FRM220-E1DATA Series card timeslot8: 0:Inactive 1:Active |
| 1.3.6.1.4.1.4756.20.220.20.1.36 | ColumnfE1DATATimeSlot9Local | read-write | current | Local FRM220-E1DATA Series card timeslot9: 0:Inactive 1:Active |
| 1.3.6.1.4.1.4756.20.220.20.1.37 | ColumnfE1DATATimeSlot10Local | read-write | current | Local FRM220-E1DATA Series card timeslot10: 0:Inactive 1:Active |
| 1.3.6.1.4.1.4756.20.220.20.1.38 | ColumnfE1DATATimeSlot11Local | read-write | current | Local FRM220-E1DATA Series card timeslot11: 0:Inactive 1:Active |
| 1.3.6.1.4.1.4756.20.220.20.1.39 | ColumnfE1DATATimeSlot12Local | read-write | current | Local FRM220-E1DATA Series card timeslot12: 0:Inactive 1:Active |
| 1.3.6.1.4.1.4756.20.220.20.1.40 | ColumnfE1DATATimeSlot13Local | read-write | current | Local FRM220-E1DATA Series card timeslot13: 0:Inactive 1:Active |
| 1.3.6.1.4.1.4756.20.220.20.1.41 | ColumnfE1DATATimeSlot14Local | read-write | current | Local FRM220-E1DATA Series card timeslot14: 0:Inactive 1:Active |
| 1.3.6.1.4.1.4756.20.220.20.1.42 | ColumnfE1DATATimeSlot15Local | read-write | current | Local FRM220-E1 Series card timeslot15: 0:Inactive 1:Active |
| 1.3.6.1.4.1.4756.20.220.20.1.43 | ColumnfE1DATATimeSlot16Local | read-write | current | Local FRM220-E1 Series card timeslot16: 0:Inactive 1:Active |
| 1.3.6.1.4.1.4756.20.220.20.1.44 | ColumnfE1DATATimeSlot17Local | read-write | current | Local FRM220-E1DATA Series card timeslot17: 0:Inactive 1:Active |
| 1.3.6.1.4.1.4756.20.220.20.1.45 | ColumnfE1DATATimeSlot18Local | read-write | current | Local FRM220-E1DATA Series card timeslot18: 0:Inactive 1:Active |
| 1.3.6.1.4.1.4756.20.220.20.1.46 | ColumnfE1DATATimeSlot19Local | read-write | current | Local FRM220-E1DATA Series card timeslot19: 0:Inactive 1:Active |
| 1.3.6.1.4.1.4756.20.220.20.1.47 | ColumnfE1DATATimeSlot20Local | read-write | current | Local FRM220-E1DATA Series card timeslot20: 0:Inactive 1:Active |
| 1.3.6.1.4.1.4756.20.220.20.1.48 | ColumnfE1DATATimeSlot21Local | read-write | current | Local FRM220-E1DATA Series card timeslot21: 0:Inactive 1:Active |
| 1.3.6.1.4.1.4756.20.220.20.1.49 | ColumnfE1DATATimeSlot22Local | read-write | current | Local FRM220-E1DATA Series card timeslot22: 0:Inactive 1:Active |
| 1.3.6.1.4.1.4756.20.220.20.1.50 | ColumnfE1DATATimeSlot23Local | read-write | current | Local FRM220-E1DATA Series card timeslot23: 0:Inactive 1:Active |
| 1.3.6.1.4.1.4756.20.220.20.1.51 | ColumnfE1DATATimeSlot24Local | read-write | current | Local FRM220-E1DATA Series card timeslot24: 0:Inactive 1:Active |
| 1.3.6.1.4.1.4756.20.220.20.1.52 | ColumnfE1DATATimeSlot25Local | read-write | current | Local FRM220-E1DATA Series card timeslot25: 0:Inactive 1:Active |
| 1.3.6.1.4.1.4756.20.220.20.1.53 | ColumnfE1DATATimeSlot26Local | read-write | current | Local FRM220-E1DATA Series card timeslot26: 0:Inactive 1:Active |
| 1.3.6.1.4.1.4756.20.220.20.1.54 | ColumnfE1DATATimeSlot27Local | read-write | current | Local FRM220-E1DATA Series card timeslot27: 0:Inactive 1:Active |
| 1.3.6.1.4.1.4756.20.220.20.1.55 | ColumnfE1DATATimeSlot28Local | read-write | current | Local FRM220-E1DATA Series card timeslot28: 0:Inactive 1:Active |
| 1.3.6.1.4.1.4756.20.220.20.1.56 | ColumnfE1DATATimeSlot29Local | read-write | current | Local FRM220-E1DATA Series card timeslot29: 0:Inactive 1:Active |
| 1.3.6.1.4.1.4756.20.220.20.1.57 | ColumnfE1DATATimeSlot30Local | read-write | current | Local FRM220-E1DATA Series card timeslot30: 0:Inactive 1:Active |
| 1.3.6.1.4.1.4756.20.220.20.1.58 | ColumnfE1DATATimeSlot31Local | read-write | current | Local FRM220-E1DATA Series card timeslot31: 0:Inactive 1:Active |
| 1.3.6.1.4.1.4756.20.220.20.1.59 | ColumnfE1DATATimeSourceLocal | read-write | current | Local FRM220-E1DATA Series card time souce: 0:Recovery from E1 1:Data port 2:Internal oscillator 3:Transparent |
| 1.3.6.1.4.1.4756.20.220.20.1.60 | ColumnfE1DATARcPolarityLocal | read-write | current | Local FRM220-E1DATA Series card RC polarity: 0:Normal 1:Invert |
| 1.3.6.1.4.1.4756.20.220.20.1.61 | ColumnfE1DATATcPolarityLocal | read-write | current | Local FRM220-E1DATA Series card TC polarity: 0:Normal 1:Invert |
| 1.3.6.1.4.1.4756.20.220.20.1.62 | ColumnfE1DATAEtcPolarityLocal | read-write | current | Local FRM220-E1DATA Series card ETC polarity: 0:Normal 1:Invert |
| 1.3.6.1.4.1.4756.20.220.20.1.63 | ColumnfE1DATALinecodeLocal | read-write | current | Local FRM220-E1DATA Series card line code: 0:HDB3 1:AMI |
| 1.3.6.1.4.1.4756.20.220.20.1.64 | ColumnfE1DATAFramerLocal | read-write | current | Local FRM220-E1DATA Series card framer mode: 0:CCS 1:CAS |
| 1.3.6.1.4.1.4756.20.220.20.1.65 | ColumnfE1DATAAisLocal | read-write | current | Local FRM220-E1DATA Series card AIS: 0:Disable 1:Enable |
| 1.3.6.1.4.1.4756.20.220.20.1.66 | ColumnfE1DATADataPortTypeLocal | read-write | current | Local FRM220-E1DATA Series card Data port type: 0:Cable adapted 1:V.35 2:RS 530 3:X.21 4:RS 232 5:RS 449 |
| 1.3.6.1.4.1.4756.20.220.20.1.67 | ColumnfE1DATADteDceLocal | read-write | current | Local FRM220-E1DATA Series card DCE/DTE mode: 0:DCE 1:DTE |
| 1.3.6.1.4.1.4756.20.220.20.1.68 | ColumnfE1DATADataPortServiceLocal | read-write | current | Local FRM220-E1DATA Series card Data port service: 0:Enable 1:Disable |
| 1.3.6.1.4.1.4756.20.220.20.1.69 | ColumnfE1DATALbsettingLocal | read-write | current | Local FRM220-E1DATA Series card Loop back test: 0:Off 1:LLB 2:RLB 3:RRLB |
| 1.3.6.1.4.1.4756.20.220.20.1.70 | ColumnfE1DATALbsettingSelLocal | read-write | current | Local FRM220-E1DATA Series card Loop back select: 0:E1 side 1:Data port side |
| 1.3.6.1.4.1.4756.20.220.20.1.71 | ColumnfE1DATABertLocal | read-write | current | Local FRM220-E1DATA Series card bert mode: 0:Disable 1:Enable |
| 1.3.6.1.4.1.4756.20.220.20.1.72 | ColumnfE1DATAUnusedTimeslotLocal | read-write | current | Local FRM220-E1DATA Series unsued time slot: 0:0X7E 1:0XFF |
| 1.3.6.1.4.1.4756.20.220.20.1.73 | ColumnfE1DATACtsRtsLocal | read-write | current | Local FRM220-E1DATA Series : 0:Follows RTS/CTS 1:Constantly on |
| 1.3.6.1.4.1.4756.20.220.20.1.74 | ColumnfE1DATADsrDtrLocal | read-write | current | Local FRM220-E1DATA Series unsued time slot: 0:Follows DSR/DTR 1:Constantly on |
| 1.3.6.1.4.1.4756.20.220.20.1.75 | ColumnfE1DATATestSTSLocal | read-write | current | Local FRM220-E1DATA Series test status: 0:Normal 1:In test |
| 1.3.6.1.4.1.4756.20.220.20.1.76 | ColumnfE1DATADataportLLBLocal | read-write | current | Local FRM220-E1DATA Series Dataport LLB Mode: 0:Disable 1:Enable |
| 1.3.6.1.4.1.4756.20.220.20.1.77 | ColumnfE1DATARateLocal | read-only | current | Local FRM220-E1DATA rate |
| 1.3.6.1.4.1.4756.20.220.20.1.78 | ColumnfE1DATADataportWorkModeLocal | read-write | current | Local FRM220-E1DATA Series Dataport Work Mode: 0:Synchronous 1:Asynchronous |
| 1.3.6.1.4.1.4756.20.221 | NodefE1DATARemoteCards | |||
| 1.3.6.1.4.1.4756.20.221.20 | TablefE1DATARemoteTable | not-accessible | current | A list of Remote FRM220-E1/DATA series card entries. The number of entries is fE1DATA-No-R. |
| 1.3.6.1.4.1.4756.20.221.20.1 | RowfE1DATARemoteEntry | not-accessible | current | An entry containing management information applicable to a particular Remote FRM220-E1/DATA series card. |
| 1.3.6.1.4.1.4756.20.221.20.1.1 | ColumnfE1DATAChassisIndexRemote | read-only | current | A unique value for each Remote card. It is the chassis location number. |
| 1.3.6.1.4.1.4756.20.221.20.1.2 | ColumnfE1DATASlotIndexRemote | read-only | current | A unique value for each Remote card. It is the slot location number. |
| 1.3.6.1.4.1.4756.20.221.20.1.3 | ColumnfE1DATACardHWVerRemote | read-only | current | Remote FRM220-E1DATA Series card hardware version x.xxx |
| 1.3.6.1.4.1.4756.20.221.20.1.4 | ColumnfE1DATACardFWVerRemote | read-only | current | Remote FRM220-E1DATA Series card firmware version x.xxx |
| 1.3.6.1.4.1.4756.20.221.20.1.5 | ColumnfE1DATACardCPLDVerRemote | read-only | current | Remote FRM220-E1DATA Series card CPLD version x.xxx |
| 1.3.6.1.4.1.4756.20.221.20.1.6 | ColumnfE1DATACardFPGAVerRemote | read-only | current | Remote FRM220-E1DATA Series card FPGA version x.xxx |
| 1.3.6.1.4.1.4756.20.221.20.1.7 | ColumnfE1DATAPortActiveRemote | read-only | current | Remote FRM220-E1DATA Series card active: 0:Disable 1:Enable |
| 1.3.6.1.4.1.4756.20.221.20.1.8 | ColumnfE1DATAPortResetRemote | read-write | current | Remote FRM220-E1DATA Series card portreset: 0:OFF 1:Action |
| 1.3.6.1.4.1.4756.20.221.20.1.9 | ColumnfE1DATASettoDefaultRemote | read-write | current | Remote FRM220-E1DATA Series card set to default: 0:OFF 1:Action |
| 1.3.6.1.4.1.4756.20.221.20.1.10 | ColumnfE1DATASignalRemote | read-only | current | Remote FRM220-E1DATA Series card E1 signal status: 0:Signal Loss 1:Normal |
| 1.3.6.1.4.1.4756.20.221.20.1.11 | ColumnfE1DATASyncRemote | read-only | current | Remote FRM220-E1DATA Series card E1 sync status: 0:Sync Loss 1:Normal |
| 1.3.6.1.4.1.4756.20.221.20.1.12 | ColumnfE1DATAReAisRemote | read-only | current | Remote FRM220-E1DATA Series card E1 receive AIS: 0:NO 1:Have |
| 1.3.6.1.4.1.4756.20.221.20.1.13 | ColumnfE1DATAE1AlarmRemote | read-only | current | Remote FRM220-E1DATA Series card E1 alarm: 0:NO 1:Have |
| 1.3.6.1.4.1.4756.20.221.20.1.14 | ColumnfE1DATALOMFRemote | read-only | current | Remote FRM220-E1DATA Series card E1 loss of multiframe sync: 0:NO 1:Have |
| 1.3.6.1.4.1.4756.20.221.20.1.15 | ColumnfE1DATALinecodeViolationRemote | read-only | current | Remote FRM220-E1DATA Series card E1 line code violation: 0:NO 1:Have |
| 1.3.6.1.4.1.4756.20.221.20.1.16 | ColumnfE1DATAConnectorRemote | read-only | current | Remote FRM220-E1DATA Series card connector type: 0:BNC 1:RJ-48C |
| 1.3.6.1.4.1.4756.20.221.20.1.17 | ColumnfE1DATARdSTSRemote | read-only | current | Remote FRM220-E1DATA Series card RD status: 0:ON 1:OFF 2:Flash |
| 1.3.6.1.4.1.4756.20.221.20.1.18 | ColumnfE1DATATdSTSRemote | read-only | current | Remote FRM220-E1DATA Series card TD status: 0:ON 1:OFF 2:Flash |
| 1.3.6.1.4.1.4756.20.221.20.1.19 | ColumnfE1DATARtsSTSRemote | read-only | current | Remote FRM220-E1DATA Series card RTS status: 0:ON 1:OFF |
| 1.3.6.1.4.1.4756.20.221.20.1.20 | ColumnfE1DATACtsSTSRemote | read-only | current | Remote FRM220-E1DATA Series card CTS status: 0:On 1:Off |
| 1.3.6.1.4.1.4756.20.221.20.1.21 | ColumnfE1DATADcdSTSRemote | read-only | current | Remote FRM220-E1DATA Series card DCD status: 0:On 1:Off |
| 1.3.6.1.4.1.4756.20.221.20.1.22 | ColumnfE1DATADsrSTSRemote | read-only | current | Remote FRM220-E1DATA Series card DSR status: 0:On 1:Off |
| 1.3.6.1.4.1.4756.20.221.20.1.23 | ColumnfE1DATADtrSTSRemote | read-only | current | Remote FRM220-E1DATA Series card DTR status: 0:On 1:Off |
| 1.3.6.1.4.1.4756.20.221.20.1.24 | ColumnfE1DATARemoPwAbRemote | read-only | current | Remote FRM220-E1DATA Series card remote power fail : 0:Normal 1:Fail |
| 1.3.6.1.4.1.4756.20.221.20.1.25 | ColumnfE1DATABertErrRemote | read-only | current | Remote FRM220-E1DATA Series card bert error : 0:No error 1:Have error |
| 1.3.6.1.4.1.4756.20.221.20.1.26 | ColumnfE1DATACableAdaptedSTSRemote | read-only | current | Remote FRM220-E1DATA Series card cable adapted status: 4:RS-530 DTE 5:RS-530 DCE 6:X.21 DTE 7:X.21 DCE 8:V.35 DTE 9:V.35 DCE 10:RS-499 DTE 11:RS-449 DCE 12:RS-… |
| 1.3.6.1.4.1.4756.20.221.20.1.27 | ColumnfE1DATAFrameRemote | read-write | current | Remote FRM220-E1DATA Series card frame mode: 0:Unframed 1:Framed |
| 1.3.6.1.4.1.4756.20.221.20.1.28 | ColumnfE1DATATimeSlot1Remote | read-write | current | Remote FRM220-E1DATA Series card timeslot1: 0:Inactive 1:Active |
| 1.3.6.1.4.1.4756.20.221.20.1.29 | ColumnfE1DATATimeSlot2Remote | read-write | current | Remote FRM220-E1DATA Series card timeslot2: 0:Inactive 1:Active |
| 1.3.6.1.4.1.4756.20.221.20.1.30 | ColumnfE1DATATimeSlot3Remote | read-write | current | Remote FRM220-E1DATA Series card timeslot3: 0:Inactive 1:Active |
| 1.3.6.1.4.1.4756.20.221.20.1.31 | ColumnfE1DATATimeSlot4Remote | read-write | current | Remote FRM220-E1DATA Series card timeslot4: 0:Inactive 1:Active |
| 1.3.6.1.4.1.4756.20.221.20.1.32 | ColumnfE1DATATimeSlot5Remote | read-write | current | Remote FRM220-E1DATA Series card timeslot5: 0:Inactive 1:Active |
| 1.3.6.1.4.1.4756.20.221.20.1.33 | ColumnfE1DATATimeSlot6Remote | read-write | current | Remote FRM220-E1DATA Series card timeslot6: 0:Inactive 1:Active |
| 1.3.6.1.4.1.4756.20.221.20.1.34 | ColumnfE1DATATimeSlot7Remote | read-write | current | Remote FRM220-E1DATA Series card timeslot7: 0:Inactive 1:Active |
| 1.3.6.1.4.1.4756.20.221.20.1.35 | ColumnfE1DATATimeSlot8Remote | read-write | current | Remote FRM220-E1DATA Series card timeslot8: 0:Inactive 1:Active |
| 1.3.6.1.4.1.4756.20.221.20.1.36 | ColumnfE1DATATimeSlot9Remote | read-write | current | Remote FRM220-E1DATA Series card timeslot9: 0:Inactive 1:Active |
| 1.3.6.1.4.1.4756.20.221.20.1.37 | ColumnfE1DATATimeSlot10Remote | read-write | current | Remote FRM220-E1DATA Series card timeslot10: 0:Inactive 1:Active |
| 1.3.6.1.4.1.4756.20.221.20.1.38 | ColumnfE1DATATimeSlot11Remote | read-write | current | Remote FRM220-E1DATA Series card timeslot11: 0:Inactive 1:Active |
| 1.3.6.1.4.1.4756.20.221.20.1.39 | ColumnfE1DATATimeSlot12Remote | read-write | current | Remote FRM220-E1DATA Series card timeslot12: 0:Inactive 1:Active |
| 1.3.6.1.4.1.4756.20.221.20.1.40 | ColumnfE1DATATimeSlot13Remote | read-write | current | Remote FRM220-E1DATA Series card timeslot13: 0:Inactive 1:Active |
| 1.3.6.1.4.1.4756.20.221.20.1.41 | ColumnfE1DATATimeSlot14Remote | read-write | current | Remote FRM220-E1DATA Series card timeslot14: 0:Inactive 1:Active |
| 1.3.6.1.4.1.4756.20.221.20.1.42 | ColumnfE1DATATimeSlot15Remote | read-write | current | Remote FRM220-E1 Series card timeslot15: 0:Inactive 1:Active |
| 1.3.6.1.4.1.4756.20.221.20.1.43 | ColumnfE1DATATimeSlot16Remote | read-write | current | Remote FRM220-E1 Series card timeslot16: 0:Inactive 1:Active |
| 1.3.6.1.4.1.4756.20.221.20.1.44 | ColumnfE1DATATimeSlot17Remote | read-write | current | Remote FRM220-E1DATA Series card timeslot17: 0:Inactive 1:Active |
| 1.3.6.1.4.1.4756.20.221.20.1.45 | ColumnfE1DATATimeSlot18Remote | read-write | current | Remote FRM220-E1DATA Series card timeslot18: 0:Inactive 1:Active |
| 1.3.6.1.4.1.4756.20.221.20.1.46 | ColumnfE1DATATimeSlot19Remote | read-write | current | Remote FRM220-E1DATA Series card timeslot19: 0:Inactive 1:Active |
| 1.3.6.1.4.1.4756.20.221.20.1.47 | ColumnfE1DATATimeSlot20Remote | read-write | current | Remote FRM220-E1DATA Series card timeslot20: 0:Inactive 1:Active |
| 1.3.6.1.4.1.4756.20.221.20.1.48 | ColumnfE1DATATimeSlot21Remote | read-write | current | Remote FRM220-E1DATA Series card timeslot21: 0:Inactive 1:Active |
| 1.3.6.1.4.1.4756.20.221.20.1.49 | ColumnfE1DATATimeSlot22Remote | read-write | current | Remote FRM220-E1DATA Series card timeslot22: 0:Inactive 1:Active |
| 1.3.6.1.4.1.4756.20.221.20.1.50 | ColumnfE1DATATimeSlot23Remote | read-write | current | Remote FRM220-E1DATA Series card timeslot23: 0:Inactive 1:Active |
| 1.3.6.1.4.1.4756.20.221.20.1.51 | ColumnfE1DATATimeSlot24Remote | read-write | current | Remote FRM220-E1DATA Series card timeslot24: 0:Inactive 1:Active |
| 1.3.6.1.4.1.4756.20.221.20.1.52 | ColumnfE1DATATimeSlot25Remote | read-write | current | Remote FRM220-E1DATA Series card timeslot25: 0:Inactive 1:Active |
| 1.3.6.1.4.1.4756.20.221.20.1.53 | ColumnfE1DATATimeSlot26Remote | read-write | current | Remote FRM220-E1DATA Series card timeslot26: 0:Inactive 1:Active |
| 1.3.6.1.4.1.4756.20.221.20.1.54 | ColumnfE1DATATimeSlot27Remote | read-write | current | Remote FRM220-E1DATA Series card timeslot27: 0:Inactive 1:Active |
| 1.3.6.1.4.1.4756.20.221.20.1.55 | ColumnfE1DATATimeSlot28Remote | read-write | current | Remote FRM220-E1DATA Series card timeslot28: 0:Inactive 1:Active |
| 1.3.6.1.4.1.4756.20.221.20.1.56 | ColumnfE1DATATimeSlot29Remote | read-write | current | Remote FRM220-E1DATA Series card timeslot29: 0:Inactive 1:Active |
| 1.3.6.1.4.1.4756.20.221.20.1.57 | ColumnfE1DATATimeSlot30Remote | read-write | current | Remote FRM220-E1DATA Series card timeslot30: 0:Inactive 1:Active |
| 1.3.6.1.4.1.4756.20.221.20.1.58 | ColumnfE1DATATimeSlot31Remote | read-write | current | Remote FRM220-E1DATA Series card timeslot31: 0:Inactive 1:Active |
| 1.3.6.1.4.1.4756.20.221.20.1.59 | ColumnfE1DATATimeSourceRemote | read-write | current | Remote FRM220-E1DATA Series card time souce: 0:Recovery from E1 1:Data port 2:Internal oscillator 3:Transparent |
| 1.3.6.1.4.1.4756.20.221.20.1.60 | ColumnfE1DATARcPolarityRemote | read-write | current | Remote FRM220-E1DATA Series card RC polarity: 0:Normal 1:Invert |
| 1.3.6.1.4.1.4756.20.221.20.1.61 | ColumnfE1DATATcPolarityRemote | read-write | current | Remote FRM220-E1DATA Series card TC polarity: 0:Normal 1:Invert |
| 1.3.6.1.4.1.4756.20.221.20.1.62 | ColumnfE1DATAEtcPolarityRemote | read-write | current | Remote FRM220-E1DATA Series card ETC polarity: 0:Normal 1:Invert |
| 1.3.6.1.4.1.4756.20.221.20.1.63 | ColumnfE1DATALinecodeRemote | read-write | current | Remote FRM220-E1DATA Series card line code: 0:HDB3 1:AMI |
| 1.3.6.1.4.1.4756.20.221.20.1.64 | ColumnfE1DATAFramerRemote | read-write | current | Remote FRM220-E1DATA Series card framer mode: 0:CCS 1:CAS |
| 1.3.6.1.4.1.4756.20.221.20.1.65 | ColumnfE1DATAAisRemote | read-write | current | Remote FRM220-E1DATA Series card AIS: 0:Disable 1:Enable |
| 1.3.6.1.4.1.4756.20.221.20.1.66 | ColumnfE1DATADataPortTypeRemote | read-write | current | Remote FRM220-E1DATA Series card Data port type: 0:Cable adapted 1:V.35 2:RS 530 3:X.21 4:RS 232 5:RS 449 |
| 1.3.6.1.4.1.4756.20.221.20.1.67 | ColumnfE1DATADteDceRemote | read-write | current | Remote FRM220-E1DATA Series card DCE/DTE mode: 0:DCE 1:DTE |
| 1.3.6.1.4.1.4756.20.221.20.1.68 | ColumnfE1DATADataPortServiceRemote | read-write | current | Remote FRM220-E1DATA Series card Data port service: 0:Enable 1:Disable |
| 1.3.6.1.4.1.4756.20.221.20.1.69 | ColumnfE1DATABertRemote | read-write | current | Remote FRM220-E1DATA Series card bert mode: 0:Disable 1:Enable |
| 1.3.6.1.4.1.4756.20.221.20.1.70 | ColumnfE1DATAUnusedTimeslotRemote | read-write | current | Remote FRM220-E1DATA Series unsued time slot: 0:0X7E 1:0XFF |
| 1.3.6.1.4.1.4756.20.221.20.1.71 | ColumnfE1DATACtsRtsRemote | read-write | current | Remote FRM220-E1DATA Series : 0:Follows RTS/CTS 1:Constantly on |
| 1.3.6.1.4.1.4756.20.221.20.1.72 | ColumnfE1DATADsrDtrRemote | read-write | current | Remote FRM220-E1DATA Series unsued time slot: 0:Follows DSR/DTR 1:Constantly on |
| 1.3.6.1.4.1.4756.20.221.20.1.73 | ColumnfE1DATATestSTSRemote | read-write | current | Remote FRM220-E1DATA Series test status: 0:Normal 1:In test |
| 1.3.6.1.4.1.4756.20.221.20.1.74 | ColumnfE1DATADataportLLBRemote | read-write | current | Remote FRM220-E1DATA Series Dataport LLB Mode: 0:Disable 1:Enable |
| 1.3.6.1.4.1.4756.20.221.20.1.75 | ColumnfE1DATARateRemote | read-only | current | Remote FRM220-E1DATA rate |
| 1.3.6.1.4.1.4756.20.221.20.1.76 | ColumnfE1DATADataportWorkModeRemote | read-write | current | Remote FRM220-E1DATA Series Dataport Work Mode: 0:Synchronous 1:Asynchronous |
| 1.3.6.1.4.1.4756.20.240 | NodefTECCards | |||
| 1.3.6.1.4.1.4756.20.240.20 | TablefTECTable | not-accessible | current | A list of local FRM220-FTEC card entries. The number of entries is FTEC cards. |
| 1.3.6.1.4.1.4756.20.240.20.1 | RowfTECEntry | not-accessible | current | An entry containing management information applicable to a particular local FRM220-FTEC card. |
| 1.3.6.1.4.1.4756.20.240.20.1.1 | ColumnfTECChassisIndex | read-only | current | A unique value for each local card. It is the chassis location number. |
| 1.3.6.1.4.1.4756.20.240.20.1.2 | ColumnfTECSlotIndex | read-only | current | A unique value for each local card. It is the slot location number. |
| 1.3.6.1.4.1.4756.20.240.20.1.3 | ColumnfTECCardHWVer | read-only | current | Local FRM220-FTEC card hardware version x.xxx |
| 1.3.6.1.4.1.4756.20.240.20.1.4 | ColumnfTECCardFWVer | read-only | current | Local FRM220-FTEC card firmware version x.xxx |
| 1.3.6.1.4.1.4756.20.240.20.1.5 | ColumnfTECCardCPLDVer | read-only | current | Local FRM220-FTEC card CPLD version x.xxx |
| 1.3.6.1.4.1.4756.20.240.20.1.6 | ColumnfTECCardFPGAVer | read-only | current | Local FRM220-FTEC card FPGA version x.xxx |
| 1.3.6.1.4.1.4756.20.240.20.1.7 | ColumnfTECPortActive | read-write | current | FRM220-FTEC Card Series card active: 0:Disable 1:Enable |
| 1.3.6.1.4.1.4756.20.240.20.1.8 | ColumnfTECPortReset | read-write | current | FRM220-FTEC Series card portreset: 0:OFF 1:Action |
| 1.3.6.1.4.1.4756.20.240.20.1.9 | ColumnfTECSettoDefault | read-write | current | FRM220-FTEC Series card set to default: 0:OFF 1:Action |
| 1.3.6.1.4.1.4756.20.240.20.1.10 | ColumnfTECSystemOKSTS | read-only | current | FRM220-FTEC system ok status 0:Have 1:No |
| 1.3.6.1.4.1.4756.20.240.20.1.11 | ColumnfTECTestSTS | read-only | current | FRM220-FTEC test status 0:Have 1:No |
| 1.3.6.1.4.1.4756.20.240.20.1.12 | ColumnfTECE1AlarmSTS | read-only | current | FRM220-FTEC E1 alarm status 0:Have 1:No |
| 1.3.6.1.4.1.4756.20.240.20.1.13 | ColumnfTECE1SignalSTS | read-only | current | FRM220-FTEC E1 signal status 0:Loss 1:Normal |
| 1.3.6.1.4.1.4756.20.240.20.1.14 | ColumnfTECE1SyncSTS | read-only | current | FRM220-FTEC E1 sync status 0:Loss 1:Sync |
| 1.3.6.1.4.1.4756.20.240.20.1.15 | ColumnfTECE1AisSTS | read-only | current | FRM220-FTEC E1 ais status 0:Have 1:No |
| 1.3.6.1.4.1.4756.20.240.20.1.16 | ColumnfTECT1AlarmSTS | read-only | current | FRM220-FTEC T1 alarm status 0:Have 1:No |
| 1.3.6.1.4.1.4756.20.240.20.1.17 | ColumnfTECT1SignalSTS | read-only | current | FRM220-FTEC T1 signal status 0:Loss 1:Normal |
| 1.3.6.1.4.1.4756.20.240.20.1.18 | ColumnfTECT1SyncSTS | read-only | current | FRM220-FTEC T1 sync status 0:Loss 1:Sync |
| 1.3.6.1.4.1.4756.20.240.20.1.19 | ColumnfTECT1AisSTS | read-only | current | FRM220-FTEC T1 ais status |
| 1.3.6.1.4.1.4756.20.240.20.1.20 | ColumnfTECE1LineCode | read-write | current | FRM220-FTEC E1 line code: 0:HDB3 1:AMI |
| 1.3.6.1.4.1.4756.20.240.20.1.21 | ColumnfTECE1Frame | read-write | current | FRM220-FTEC E1 frame formats: 0:CCS 1:CAS |
| 1.3.6.1.4.1.4756.20.240.20.1.22 | ColumnfTECE1Crc4 | read-write | current | FRM220-FTEC E1 crc4: 0:disable 1:enable |
| 1.3.6.1.4.1.4756.20.240.20.1.23 | ColumnfTECE1LineImpedance | read-write | current | FRM220-FTEC E1 line impedance: 0:120 ohm 1:75 ohm |
| 1.3.6.1.4.1.4756.20.240.20.1.24 | ColumnfTECUnUsedTimeslot | read-write | current | FRM220-FTEC unused timeslot: 0:0X7E 1:0XFF |
| 1.3.6.1.4.1.4756.20.240.20.1.25 | ColumnfTECT1LineBuild | read-write | current | FRM220-FTEC T1 line build-out select: 0:0-133 feet/0dB CSU 1:133-266 feet 2:266-399 feet 3:399-533 feet 4:533-655 feet 5:-7.5dB CSU 6:-15dB CSU 7:-22.5dB CSU |
| 1.3.6.1.4.1.4756.20.240.20.1.26 | ColumnfTECT1LineCode | read-write | current | FRM220-FTEC T1 line code: 0:B8ZS 1:AMI |
| 1.3.6.1.4.1.4756.20.240.20.1.27 | ColumnfTECT1Frame | read-write | current | FRM220-FTEC T1 frame formats: 0:SF(D4) 1:ESF |
| 1.3.6.1.4.1.4756.20.240.20.1.28 | ColumnfTECTimesource | read-write | current | FRM220-FTEC timesource: 0:Transparent 1:E1 side recovery 2:T1 side recovery 3:Internal oscillator 4:Loopback |
| 1.3.6.1.4.1.4756.20.240.20.1.29 | ColumnfTECSignalingmode | read-write | current | FRM220-FTEC signaling mode: 0:Signaling disable 1:According ABCD 2:T1 E&M signaling to E1 MFC R2 signaling 3:According to signaling table A 4:G.802 Annex B fun… |
| 1.3.6.1.4.1.4756.20.240.20.1.30 | ColumnfTECSignalingBitA | read-write | current | FRM220-FTEC signaling Bit A: 0:Noe invert 1:Invert 2:Always 0 3:Always 1 |
| 1.3.6.1.4.1.4756.20.240.20.1.31 | ColumnfTECSignalingBitB | read-write | current | FRM220-FTEC signaling Bit B: 0:Not invert 1:Invert 2:Always 0 3:Always 1 |
| 1.3.6.1.4.1.4756.20.240.20.1.32 | ColumnfTECSignalingBitC | read-write | current | FRM220-FTEC signaling Bit C: 0:Not invert 1:Invert 2:Always 0 3:Always 1 |
| 1.3.6.1.4.1.4756.20.240.20.1.33 | ColumnfTECSignalingBitD | read-write | current | FRM220-FTEC signaling Bit D: 0:Not invert 1:Invert 2:Always 0 3:Always 1 |
| 1.3.6.1.4.1.4756.20.240.20.1.34 | ColumnfTECE1Loopback | read-write | current | FRM220-FTEC E1 loopback: 0:Off 1:LLB 2:RLB |
| 1.3.6.1.4.1.4756.20.240.20.1.35 | ColumnfTECT1Loopback | read-write | current | FRM220-FTEC T1 loopback: 0:Off 1:LLB 2:RLB |
| 1.3.6.1.4.1.4756.20.240.20.1.36 | ColumnfTECFrontpanelLoopback | read-write | current | FRM220-FTEC front panel loopback: 0:Disable 1:Enable |
| 1.3.6.1.4.1.4756.20.240.20.1.37 | ColumnfTECE1Timeslot1 | read-write | current | FRM220-FTEC E1 timeslot 1: 0:No use 1:used |
| 1.3.6.1.4.1.4756.20.240.20.1.38 | ColumnfTECE1Timeslot2 | read-write | current | FRM220-FTEC E1 timeslot 2: 0:No use 1:used |
| 1.3.6.1.4.1.4756.20.240.20.1.39 | ColumnfTECE1Timeslot3 | read-write | current | FRM220-FTEC E1 timeslot 3: 0:No use 1:used |
| 1.3.6.1.4.1.4756.20.240.20.1.40 | ColumnfTECE1Timeslot4 | read-write | current | FRM220-FTEC E1 timeslot 4: 0:No use 1:used |
| 1.3.6.1.4.1.4756.20.240.20.1.41 | ColumnfTECE1Timeslot5 | read-write | current | FRM220-FTEC E1 timeslot 5: 0:No use 1:used |
| 1.3.6.1.4.1.4756.20.240.20.1.42 | ColumnfTECE1Timeslot6 | read-write | current | FRM220-FTEC E1 timeslot 6: 0:No use 1:used |
| 1.3.6.1.4.1.4756.20.240.20.1.43 | ColumnfTECE1Timeslot7 | read-write | current | FRM220-FTEC E1 timeslot 7: 0:No use 1:used |
| 1.3.6.1.4.1.4756.20.240.20.1.44 | ColumnfTECE1Timeslot8 | read-write | current | FRM220-FTEC E1 timeslot 8: 0:No use 1:used |
| 1.3.6.1.4.1.4756.20.240.20.1.45 | ColumnfTECE1Timeslot9 | read-write | current | FRM220-FTEC E1 timeslot 9: 0:No use 1:used |
| 1.3.6.1.4.1.4756.20.240.20.1.46 | ColumnfTECE1Timeslot10 | read-write | current | FRM220-FTEC E1 timeslot 10: 0:No use 1:used |
| 1.3.6.1.4.1.4756.20.240.20.1.47 | ColumnfTECE1Timeslot11 | read-write | current | FRM220-FTEC E1 timeslot 11: 0:No use 1:used |
| 1.3.6.1.4.1.4756.20.240.20.1.48 | ColumnfTECE1Timeslot12 | read-write | current | FRM220-FTEC E1 timeslot 12: 0:No use 1:used |
| 1.3.6.1.4.1.4756.20.240.20.1.49 | ColumnfTECE1Timeslot13 | read-write | current | FRM220-FTEC E1 timeslot 13: 0:No use 1:used |
| 1.3.6.1.4.1.4756.20.240.20.1.50 | ColumnfTECE1Timeslot14 | read-write | current | FRM220-FTEC E1 timeslot 14: 0:No use 1:used |
| 1.3.6.1.4.1.4756.20.240.20.1.51 | ColumnfTECE1Timeslot15 | read-write | current | FRM220-FTEC E1 timeslot 15: 0:No use 1:used |
| 1.3.6.1.4.1.4756.20.240.20.1.52 | ColumnfTECE1Timeslot16 | read-write | current | FRM220-FTEC E1 timeslot 16: 0:No use 1:used |
| 1.3.6.1.4.1.4756.20.240.20.1.53 | ColumnfTECE1Timeslot17 | read-write | current | FRM220-FTEC E1 timeslot 17: 0:No use 1:used |
| 1.3.6.1.4.1.4756.20.240.20.1.54 | ColumnfTECE1Timeslot18 | read-write | current | FRM220-FTEC E1 timeslot 18: 0:No use 1:used |
| 1.3.6.1.4.1.4756.20.240.20.1.55 | ColumnfTECE1Timeslot19 | read-write | current | FRM220-FTEC E1 timeslot 19: 0:No use 1:used |
| 1.3.6.1.4.1.4756.20.240.20.1.56 | ColumnfTECE1Timeslot20 | read-write | current | FRM220-FTEC E1 timeslot 20: 0:No use 1:used |
| 1.3.6.1.4.1.4756.20.240.20.1.57 | ColumnfTECE1Timeslot21 | read-write | current | FRM220-FTEC E1 timeslot 21: 0:No use 1:used |
| 1.3.6.1.4.1.4756.20.240.20.1.58 | ColumnfTECE1Timeslot22 | read-write | current | FRM220-FTEC E1 timeslot 22: 0:No use 1:used |
| 1.3.6.1.4.1.4756.20.240.20.1.59 | ColumnfTECE1Timeslot23 | read-write | current | FRM220-FTEC E1 timeslot 23: 0:No use 1:used |
| 1.3.6.1.4.1.4756.20.240.20.1.60 | ColumnfTECE1Timeslot24 | read-write | current | FRM220-FTEC E1 timeslot 24: 0:No use 1:used |
| 1.3.6.1.4.1.4756.20.240.20.1.61 | ColumnfTECE1Timeslot25 | read-write | current | FRM220-FTEC E1 timeslot 25: 0:No use 1:used |
| 1.3.6.1.4.1.4756.20.240.20.1.62 | ColumnfTECE1Timeslot26 | read-write | current | FRM220-FTEC E1 timeslot 26: 0:No use 1:used |
| 1.3.6.1.4.1.4756.20.240.20.1.63 | ColumnfTECE1Timeslot27 | read-write | current | FRM220-FTEC E1 timeslot 27: 0:No use 1:used |
| 1.3.6.1.4.1.4756.20.240.20.1.64 | ColumnfTECE1Timeslot28 | read-write | current | FRM220-FTEC E1 timeslot 28: 0:No use 1:used |
| 1.3.6.1.4.1.4756.20.240.20.1.65 | ColumnfTECE1Timeslot29 | read-write | current | FRM220-FTEC E1 timeslot 29: 0:No use 1:used |
| 1.3.6.1.4.1.4756.20.240.20.1.66 | ColumnfTECE1Timeslot30 | read-write | current | FRM220-FTEC E1 timeslot 30: 0:No use 1:used |
| 1.3.6.1.4.1.4756.20.240.20.1.67 | ColumnfTECE1Timeslot31 | read-write | current | FRM220-FTEC E1 timeslot 31: 0:No use 1:used |
| 1.3.6.1.4.1.4756.20.240.20.1.68 | ColumnfTECDataVoice1 | read-write | current | FRM220-FTEC Data/Voice 1: 0:Data 1:Voice |
| 1.3.6.1.4.1.4756.20.240.20.1.69 | ColumnfTECDataVoice2 | read-write | current | FRM220-FTEC Data/Voice 2: 0:Data 1:Voice |
| 1.3.6.1.4.1.4756.20.240.20.1.70 | ColumnfTECDataVoice3 | read-write | current | FRM220-FTEC Data/Voice 3: 0:Data 1:Voice |
| 1.3.6.1.4.1.4756.20.240.20.1.71 | ColumnfTECDataVoice4 | read-write | current | FRM220-FTEC Data/Voice 4: 0:Data 1:Voice |
| 1.3.6.1.4.1.4756.20.240.20.1.72 | ColumnfTECDataVoice5 | read-write | current | FRM220-FTEC Data/Voice 5: 0:Data 1:Voice |
| 1.3.6.1.4.1.4756.20.240.20.1.73 | ColumnfTECDataVoice6 | read-write | current | FRM220-FTEC Data/Voice 6: 0:Data 1:Voice |
| 1.3.6.1.4.1.4756.20.240.20.1.74 | ColumnfTECDataVoice7 | read-write | current | FRM220-FTEC Data/Voice 7: 0:Data 1:Voice |
| 1.3.6.1.4.1.4756.20.240.20.1.75 | ColumnfTECDataVoice8 | read-write | current | FRM220-FTEC Data/Voice 8: 0:Data 1:Voice |
| 1.3.6.1.4.1.4756.20.240.20.1.76 | ColumnfTECDataVoice9 | read-write | current | FRM220-FTEC Data/Voice 9: 0:Data 1:Voice |
| 1.3.6.1.4.1.4756.20.240.20.1.77 | ColumnfTECDataVoice10 | read-write | current | FRM220-FTEC Data/Voice 10: 0:Data 1:Voice |
| 1.3.6.1.4.1.4756.20.240.20.1.78 | ColumnfTECDataVoice11 | read-write | current | FRM220-FTEC Data/Voice 11: 0:Data 1:Voice |
| 1.3.6.1.4.1.4756.20.240.20.1.79 | ColumnfTECDataVoice12 | read-write | current | FRM220-FTEC Data/Voice 12: 0:Data 1:Voice |
| 1.3.6.1.4.1.4756.20.240.20.1.80 | ColumnfTECDataVoice13 | read-write | current | FRM220-FTEC Data/Voice 13: 0:Data 1:Voice |
| 1.3.6.1.4.1.4756.20.240.20.1.81 | ColumnfTECDataVoice14 | read-write | current | FRM220-FTEC Data/Voice 14: 0:Data 1:Voice |
| 1.3.6.1.4.1.4756.20.240.20.1.82 | ColumnfTECDataVoice15 | read-write | current | FRM220-FTEC Data/Voice 15: 0:Data 1:Voice |
| 1.3.6.1.4.1.4756.20.240.20.1.83 | ColumnfTECDataVoice16 | read-write | current | FRM220-FTEC Data/Voice 16: 0:Data 1:Voice |
| 1.3.6.1.4.1.4756.20.240.20.1.84 | ColumnfTECDataVoice17 | read-write | current | FRM220-FTEC Data/Voice 17: 0:Data 1:Voice |
| 1.3.6.1.4.1.4756.20.240.20.1.85 | ColumnfTECDataVoice18 | read-write | current | FRM220-FTEC Data/Voice 18: 0:Data 1:Voice |
| 1.3.6.1.4.1.4756.20.240.20.1.86 | ColumnfTECDataVoice19 | read-write | current | FRM220-FTEC Data/Voice 19: 0:Data 1:Voice |
| 1.3.6.1.4.1.4756.20.240.20.1.87 | ColumnfTECDataVoice20 | read-write | current | FRM220-FTEC Data/Voice 20: 0:Data 1:Voice |
| 1.3.6.1.4.1.4756.20.240.20.1.88 | ColumnfTECDataVoice21 | read-write | current | FRM220-FTEC Data/Voice 21: 0:Data 1:Voice |
| 1.3.6.1.4.1.4756.20.240.20.1.89 | ColumnfTECDataVoice22 | read-write | current | FRM220-FTEC Data/Voice 22: 0:Data 1:Voice |
| 1.3.6.1.4.1.4756.20.240.20.1.90 | ColumnfTECDataVoice23 | read-write | current | FRM220-FTEC Data/Voice 23: 0:Data 1:Voice |
| 1.3.6.1.4.1.4756.20.240.20.1.91 | ColumnfTECDataVoice24 | read-write | current | FRM220-FTEC Data/Voice 24: 0:Data 1:Voice |
| 1.3.6.1.4.1.4756.20.250 | Nodefom04LocalCards | |||
| 1.3.6.1.4.1.4756.20.250.20 | Tablefom04LocalTable | not-accessible | current | A list of local FRM220-FOM04 series card entries. The number of entries is fom04-No-L. |
| 1.3.6.1.4.1.4756.20.250.20.1 | Rowfom04LocalEntry | not-accessible | current | An entry containing management information applicable to a particular local FRM220-FOM04 series card. |
| 1.3.6.1.4.1.4756.20.250.20.1.1 | Columnfom04ChassisIndexLocal | read-only | current | A unique value for each local card. It is the chassis location number. |
| 1.3.6.1.4.1.4756.20.250.20.1.2 | Columnfom04SlotIndexLocal | read-only | current | A unique value for each local card. It is the slot location number. |
| 1.3.6.1.4.1.4756.20.250.20.1.3 | Columnfom04CardHWVerLocal | read-only | current | Local FRM220-FOM04 Series card hardware version x.xxx |
| 1.3.6.1.4.1.4756.20.250.20.1.4 | Columnfom04CardFWVerLocal | read-only | current | Local FRM220-FOM04 Series card firmware version x.xxx |
| 1.3.6.1.4.1.4756.20.250.20.1.5 | Columnfom04CardCPLDVerLocal | read-only | current | Local FRM220-FOM04 Series card CPLD version x.xxx |
| 1.3.6.1.4.1.4756.20.250.20.1.6 | Columnfom04CardFPGAVerLocal | read-only | current | Local FRM220-FOM04 Series card FPGA version x.xxx |
| 1.3.6.1.4.1.4756.20.250.20.1.7 | Columnfom04PortActiveLocal | read-write | current | Local FRM220-FOM04 Series card active: 0:Disable 1:Enable |
| 1.3.6.1.4.1.4756.20.250.20.1.8 | Columnfom04SettoDefaultLocal | read-write | current | Local FRM220-FOM04 Series card set to default: 0:OFF 1:Action |
| 1.3.6.1.4.1.4756.20.250.20.1.9 | Columnfom04PortResetLocal | read-write | current | Local FRM220-FOM04 Series card portreset: 0:OFF 1:Action |
| 1.3.6.1.4.1.4756.20.250.20.1.10 | Columnfom04FxLinkLocal | read-only | current | Local FRM220-FOM04 fiber link status: 0:Down 1:up |
| 1.3.6.1.4.1.4756.20.250.20.1.11 | Columnfom04FxWorkCHLocal | read-write | current | Local FRM220-FOM04 fiber work channel: 0:Optical 1 1:Optical 2 |
| 1.3.6.1.4.1.4756.20.250.20.1.12 | Columnfom04Fx1RxLinkLocal | read-only | current | Local FRM220-FOM04 fiber 1 rx loss status: 0:Down 1:Up |
| 1.3.6.1.4.1.4756.20.250.20.1.13 | Columnfom04Fx2RxLinkLocal | read-only | current | Local FRM220-FOM04 fiber 1 rx loss status: 0:Down 1:Up |
| 1.3.6.1.4.1.4756.20.250.20.1.14 | Columnfom04FxLBSettingLocal | read-write | current | Local FRM220-FOM04 loopback mode: 0:Disable 1:LLB 2:RLB |
| 1.3.6.1.4.1.4756.20.250.20.1.15 | Columnfom04Utp1LinkLocal | read-only | current | Local FRM220-FOM04 UTP 1 link status: 0:Down 1:Up |
| 1.3.6.1.4.1.4756.20.250.20.1.16 | Columnfom04Utp1NegoSTSLocal | read-only | current | Local FRM220-FOM04 UTP 1 negotiation status: 0:Manual 1:Auto |
| 1.3.6.1.4.1.4756.20.250.20.1.17 | Columnfom04Utp1SpeedSTSLocal | read-only | current | Local FRM220-FOM04 UTP 1 speed status: 0:10M 1:100M |
| 1.3.6.1.4.1.4756.20.250.20.1.18 | Columnfom04Utp1DuplexSTSLocal | read-only | current | Local FRM220-FOM04 UTP 1 duplex status: 0:Half 1:Full |
| 1.3.6.1.4.1.4756.20.250.20.1.19 | Columnfom04Utp1ActiveLocal | read-write | current | Local FRM220-FOM04 UTP 1 port active: 0:Disable 1:Enable |
| 1.3.6.1.4.1.4756.20.250.20.1.20 | Columnfom04Utp1NegoLocal | read-write | current | Local FRM220-FOM04 UTP 1 negoiation: 0:Manual 1:Auto |
| 1.3.6.1.4.1.4756.20.250.20.1.21 | Columnfom04Utp1SpeedLocal | read-write | current | Local FRM220-FOM04 UTP 1 speed: 0:On 1:Off |
| 1.3.6.1.4.1.4756.20.250.20.1.22 | Columnfom04Utp1DuplexLocal | read-write | current | Local FRM220-FOM04 UTP 1 duplex: 0:Half 1:Full |
| 1.3.6.1.4.1.4756.20.250.20.1.23 | Columnfom04Utp2LinkLocal | read-only | current | Local FRM220-FOM04 UTP 2 link status: 0:Down 1:Up |
| 1.3.6.1.4.1.4756.20.250.20.1.24 | Columnfom04Utp2NegoSTSLocal | read-only | current | Local FRM220-FOM04 UTP 2 negotiation status: 0:Manual 1:Auto |
| 1.3.6.1.4.1.4756.20.250.20.1.25 | Columnfom04Utp2SpeedSTSLocal | read-only | current | Local FRM220-FOM04 UTP 2 speed status: 0:10M 1:100M |
| 1.3.6.1.4.1.4756.20.250.20.1.26 | Columnfom04Utp2DuplexSTSLocal | read-only | current | Local FRM220-FOM04 UTP 2 duplex status: 0:Half 1:Full |
| 1.3.6.1.4.1.4756.20.250.20.1.27 | Columnfom04Utp2ActiveLocal | read-write | current | Local FRM220-FOM04 UTP 2 port active: 0:Disable 1:Enable |
| 1.3.6.1.4.1.4756.20.250.20.1.28 | Columnfom04Utp2NegoLocal | read-write | current | Local FRM220-FOM04 UTP 2 negoiation: 0:Manual 1:Auto |
| 1.3.6.1.4.1.4756.20.250.20.1.29 | Columnfom04Utp2SpeedLocal | read-write | current | Local FRM220-FOM04 UTP 2 speed: 0:On 1:Off |
| 1.3.6.1.4.1.4756.20.250.20.1.30 | Columnfom04Utp2DuplexLocal | read-write | current | Local FRM220-FOM04 UTP 2 duplex: 0:Half 1:Full |
| 1.3.6.1.4.1.4756.20.250.20.1.31 | Columnfom04Utp3LinkLocal | read-only | current | Local FRM220-FOM04 UTP 3 link status: 0:Down 1:Up |
| 1.3.6.1.4.1.4756.20.250.20.1.32 | Columnfom04Utp3NegoSTSLocal | read-only | current | Local FRM220-FOM04 UTP 3 negotiation status: 0:Manual 1:Auto |
| 1.3.6.1.4.1.4756.20.250.20.1.33 | Columnfom04Utp3SpeedSTSLocal | read-only | current | Local FRM220-FOM04 UTP 3 speed status: 0:10M 1:100M |
| 1.3.6.1.4.1.4756.20.250.20.1.34 | Columnfom04Utp3DuplexSTSLocal | read-only | current | Local FRM220-FOM04 UTP 3 duplex status: 0:Half 1:Full |
| 1.3.6.1.4.1.4756.20.250.20.1.35 | Columnfom04Utp3ActiveLocal | read-write | current | Local FRM220-FOM04 UTP 3 port active: 0:Disable 1:Enable |
| 1.3.6.1.4.1.4756.20.250.20.1.36 | Columnfom04Utp3NegoLocal | read-write | current | Local FRM220-FOM04 UTP 3 negoiation: 0:Manual 1:Auto |
| 1.3.6.1.4.1.4756.20.250.20.1.37 | Columnfom04Utp3SpeedLocal | read-write | current | Local FRM220-FOM04 UTP 3 speed: 0:On 1:Off |
| 1.3.6.1.4.1.4756.20.250.20.1.38 | Columnfom04Utp3DuplexLocal | read-write | current | Local FRM220-FOM04 UTP 3 duplex: 0:Half 1:Full |
| 1.3.6.1.4.1.4756.20.250.20.1.39 | Columnfom04RS232ActiveLocal | read-write | current | Local FRM220-FOM04 RS232 port active: 0:Disable 1:Enable |
| 1.3.6.1.4.1.4756.20.250.20.1.40 | Columnfom04RS232DataActiveLocal | read-only | current | Local FRM220-FOM04 RS232 Rx active status: 0:OFF 1:ON |
| 1.3.6.1.4.1.4756.20.250.20.1.41 | Columnfom04RS232LBSettingLocal | read-write | current | Local FRM220-FOM04 RS232 loopback : 0:Disable 1:LLB 2:RLB |
| 1.3.6.1.4.1.4756.20.250.20.1.42 | Columnfom04E1T1TermLocal | read-write | current | Local FRM220-FOM04 E1T1 termination type: 0:E1/75/BNC 1:E1/120/RJ45 2:T1/100/RJ45 |
| 1.3.6.1.4.1.4756.20.250.20.1.43 | Columnfom04E1T1CH1ActiveLocal | read-write | current | Local FRM220-FOM04 E1T1 channel 1 port active : 0:Disable 1:Enalbe |
| 1.3.6.1.4.1.4756.20.250.20.1.44 | Columnfom04E1T1CH1LinkLocal | read-only | current | Local FRM220-FOM04 E1T1 channel 1 link status: 0:Down 1:Up |
| 1.3.6.1.4.1.4756.20.250.20.1.45 | Columnfom04E1T1CH1BVPErrorLocal | read-only | current | Local FRM220-FOM04 E1T1 channel 1 BVP error status : 0:Normal 1:Error |
| 1.3.6.1.4.1.4756.20.250.20.1.46 | Columnfom04E1T1CH1LineCodeLocal | read-write | current | Local FRM220-FOM04 E1T1 channel 1 line code: 0:HDB3/B8ZS 1:AMI |
| 1.3.6.1.4.1.4756.20.250.20.1.47 | Columnfom04E1T1CH1ELBLocal | read-write | current | Local FRM220-FOM04 E1T1 channel 1 E1 loopback: 0:Disable 1:LLB 2:RLB |
| 1.3.6.1.4.1.4756.20.250.20.1.48 | Columnfom04E1T1CH1RcvAISLocal | read-only | current | Local FRM220-FOM04 E1T1 channel 1 Rev AIS: 0:OFF 1:ON |
| 1.3.6.1.4.1.4756.20.250.20.1.49 | Columnfom04E1T1CH2ActiveLocal | read-write | current | Local FRM220-FOM04 E1T1 channel 2 port active : 0:Disable 1:Enalbe |
| 1.3.6.1.4.1.4756.20.250.20.1.50 | Columnfom04E1T1CH2LinkLocal | read-only | current | Local FRM220-FOM04 E1T1 channel 2 link status: 0:Down 1:Up |
| 1.3.6.1.4.1.4756.20.250.20.1.51 | Columnfom04E1T1CH2BVPErrorLocal | read-only | current | Local FRM220-FOM04 E1T1 channel 2 BVP error status : 0:Normal 1:Error |
| 1.3.6.1.4.1.4756.20.250.20.1.52 | Columnfom04E1T1CH2LineCodeLocal | read-write | current | Local FRM220-FOM04 E1T1 channel 2 line code: 0:HDB3/B8ZS 1:AMI |
| 1.3.6.1.4.1.4756.20.250.20.1.53 | Columnfom04E1T1CH2ELBLocal | read-write | current | Local FRM220-FOM04 E1T1 channel 2 E1 loopback: 0:Disable 1:LLB 2:RLB |
| 1.3.6.1.4.1.4756.20.250.20.1.54 | Columnfom04E1T1CH2RcvAISLocal | read-only | current | Local FRM220-FOM04 E1T1 channel 2 Rev AIS: 0:OFF 1:ON |
| 1.3.6.1.4.1.4756.20.250.20.1.55 | Columnfom04E1T1CH3ActiveLocal | read-write | current | Local FRM220-FOM04 E1T1 channel 3 port active : 0:Disable 1:Enalbe |
| 1.3.6.1.4.1.4756.20.250.20.1.56 | Columnfom04E1T1CH3LinkLocal | read-only | current | Local FRM220-FOM04 E1T1 channel 3 link status: 0:Down 1:Up |
| 1.3.6.1.4.1.4756.20.250.20.1.57 | Columnfom04E1T1CH3BVPErrorLocal | read-only | current | Local FRM220-FOM04 E1T1 channel 3 BVP error status : 0:Normal 1:Error |
| 1.3.6.1.4.1.4756.20.250.20.1.58 | Columnfom04E1T1CH3LineCodeLocal | read-write | current | Local FRM220-FOM04 E1T1 channel 3 line code: 0:HDB3/B8ZS 1:AMI |
| 1.3.6.1.4.1.4756.20.250.20.1.59 | Columnfom04E1T1CH3ELBLocal | read-write | current | Local FRM220-FOM04 E1T1 channel 3 E1 loopback: 0:Disable 1:LLB 2:RLB |
| 1.3.6.1.4.1.4756.20.250.20.1.60 | Columnfom04E1T1CH3RcvAISLocal | read-only | current | Local FRM220-FOM04 E1T1 channel 3 Rev AIS: 0:OFF 1:ON |
| 1.3.6.1.4.1.4756.20.250.20.1.61 | Columnfom04E1T1CH4ActiveLocal | read-write | current | Local FRM220-FOM04 E1T1 channel 4 port active : 0:Disable 1:Enalbe |
| 1.3.6.1.4.1.4756.20.250.20.1.62 | Columnfom04E1T1CH4LinkLocal | read-only | current | Local FRM220-FOM04 E1T1 channel 4 link status: 0:Down 1:Up |
| 1.3.6.1.4.1.4756.20.250.20.1.63 | Columnfom04E1T1CH4BVPErrorLocal | read-only | current | Local FRM220-FOM04 E1T1 channel 4 BVP error status : 0:Normal 1:Error |
| 1.3.6.1.4.1.4756.20.250.20.1.64 | Columnfom04E1T1CH4LineCodeLocal | read-write | current | Local FRM220-FOM04 E1T1 channel 4 line code: 0:HDB3/B8ZS 1:AMI |
| 1.3.6.1.4.1.4756.20.250.20.1.65 | Columnfom04E1T1CH4ELBLocal | read-write | current | Local FRM220-FOM04 E1T1 channel 4 E1 loopback: 0:Disable 1:LLB 2:RLB |
| 1.3.6.1.4.1.4756.20.250.20.1.66 | Columnfom04E1T1CH4RcvAISLocal | read-only | current | Local FRM220-FOM04 E1T1 channel 4 Rev AIS: 0:OFF 1:ON |
| 1.3.6.1.4.1.4756.20.250.20.1.67 | Columnfom04PhoneActiveLocal | read-write | current | Local FRM220-FOM04 phone port active : 0:Disable 1:Enable |
| 1.3.6.1.4.1.4756.20.250.20.1.68 | Columnfom04CallOutLocal | read-write | current | Local FRM220-FOM04 call out : 0:OFF 1:ON |
| 1.3.6.1.4.1.4756.20.250.20.1.69 | Columnfom04RemotePWRLocal | read-only | current | Local FRM220-FOM04 Remote power fail: 0:Ok 1:Abnormal |
| 1.3.6.1.4.1.4756.20.250.20.1.70 | Columnfom04LfpModeLocal | read-write | current | Local FRM220-FOM04 LFP mode: 0:Disable 1:Enable |
| 1.3.6.1.4.1.4756.20.250.20.1.71 | Columnfom04AlsModeLocal | read-write | current | Local FRM220-FOM04 ALS mode: 0:Disable 1:Enable |
| 1.3.6.1.4.1.4756.20.250.20.1.72 | Columnfom04SnmpPortLocal | read-write | current | Local FRM220-FOM04 SNMP VLAN : 0:No VLAN 1:Port 1 VLAN |
| 1.3.6.1.4.1.4756.20.250.20.1.73 | Columnfom04PWR1Local | read-only | current | Local FRM220-FOM04 PWR 1 (AC): 0:Fail 1:Ok 2:None |
| 1.3.6.1.4.1.4756.20.250.20.1.74 | Columnfom04PWR2Local | read-only | current | Local FRM220-FOM04 PWR 2 (DC): 0:Fail 1:Ok 2:None |
| 1.3.6.1.4.1.4756.20.250.20.1.75 | Columnfom04Fx1DDLocal | read-only | current | Local device card fiber port 1 Digital Diagnostic function: 0:No 1:Yes |
| 1.3.6.1.4.1.4756.20.250.20.1.76 | Columnfom04Fx1DDVendorLocal | read-only | current | Local device card fiber port 1 D/D information: Vendor name |
| 1.3.6.1.4.1.4756.20.250.20.1.77 | Columnfom04Fx1DDPartNoLocal | read-only | current | Local device card fiber port 1 D/D information: Vendor part number |
| 1.3.6.1.4.1.4756.20.250.20.1.78 | Columnfom04Fx1DDFiberTypeLocal | read-only | current | Local device card fiber port 1 D/D information: Fiber Type |
| 1.3.6.1.4.1.4756.20.250.20.1.79 | Columnfom04Fx1DDWaveLenLocal | read-only | current | Local device card fiber port 1 D/D information: Wave length |
| 1.3.6.1.4.1.4756.20.250.20.1.80 | Columnfom04Fx1DDWaveLen2Local | read-only | current | Local device card fiber port 1 D/D information: Wave length 2 |
| 1.3.6.1.4.1.4756.20.250.20.1.81 | Columnfom04Fx1DDLinkLenLocal | read-only | current | Local device card fiber port 1 D/D information: Link length |
| 1.3.6.1.4.1.4756.20.250.20.1.82 | Columnfom04Fx1DDLenUnitLocal | read-only | current | Local device card fiber port 1 D/D information: Length Unit |
| 1.3.6.1.4.1.4756.20.250.20.1.83 | Columnfom04Fx1DDStatusLocal | read-only | current | Local device card fiber port 1 D/D information: Status Support |
| 1.3.6.1.4.1.4756.20.250.20.1.84 | Columnfom04Fx1DDRxSensLocal | read-only | current | Local device card fiber port 1 D/D information: Rx Sensitivity |
| 1.3.6.1.4.1.4756.20.250.20.1.85 | Columnfom04Fx1DDTxPWRLocal | read-only | current | Local device card fiber port 1 D/D information: Tx power |
| 1.3.6.1.4.1.4756.20.250.20.1.86 | Columnfom04Fx1DDRxPWRLocal | read-only | current | Local device card fiber port 1 D/D information: Rx power |
| 1.3.6.1.4.1.4756.20.250.20.1.87 | Columnfom04Fx1DDTempLocal | read-only | current | Local device card fiber port 1 D/D information: Temperature in degree C |
| 1.3.6.1.4.1.4756.20.250.20.1.88 | Columnfom04Fx1DDPWRMarginLocal | read-only | current | Local device card fiber port 1 D/D information: Power margin |
| 1.3.6.1.4.1.4756.20.250.20.1.89 | Columnfom04Fx2DDLocal | read-only | current | Local device card fiber port 2 Digital Diagnostic function: 0:No 1:Yes |
| 1.3.6.1.4.1.4756.20.250.20.1.90 | Columnfom04Fx2DDVendorLocal | read-only | current | Local device card fiber port 2 D/D information: Vendor name |
| 1.3.6.1.4.1.4756.20.250.20.1.91 | Columnfom04Fx2DDPartNoLocal | read-only | current | Local device card fiber port 2 D/D information: Vendor part number |
| 1.3.6.1.4.1.4756.20.250.20.1.92 | Columnfom04Fx2DDFiberTypeLocal | read-only | current | Local device card fiber port 2 D/D information: Fiber Type |
| 1.3.6.1.4.1.4756.20.250.20.1.93 | Columnfom04Fx2DDWaveLenLocal | read-only | current | Local device card fiber port 2 D/D information: Wave length |
| 1.3.6.1.4.1.4756.20.250.20.1.94 | Columnfom04Fx2DDWaveLen2Local | read-only | current | Local device card fiber port 2 D/D information: Wave length 2 |
| 1.3.6.1.4.1.4756.20.250.20.1.95 | Columnfom04Fx2DDLinkLenLocal | read-only | current | Local device card fiber port 2 D/D information: Link length |
| 1.3.6.1.4.1.4756.20.250.20.1.96 | Columnfom04Fx2DDLenUnitLocal | read-only | current | Local device card fiber port 2 D/D information: Length Unit |
| 1.3.6.1.4.1.4756.20.250.20.1.97 | Columnfom04Fx2DDStatusLocal | read-only | current | Local device card fiber port 2 D/D information: Status Support |
| 1.3.6.1.4.1.4756.20.250.20.1.98 | Columnfom04Fx2DDRxSensLocal | read-only | current | Local device card fiber port 2 D/D information: Rx Sensitivity |
| 1.3.6.1.4.1.4756.20.250.20.1.99 | Columnfom04Fx2DDTxPWRLocal | read-only | current | Local device card fiber port 2 D/D information: Tx power |
| 1.3.6.1.4.1.4756.20.250.20.1.100 | Columnfom04Fx2DDRxPWRLocal | read-only | current | Local device card fiber port 2 D/D information: Rx power |
| 1.3.6.1.4.1.4756.20.250.20.1.101 | Columnfom04Fx2DDTempLocal | read-only | current | Local device card fiber port 2 D/D information: Temperature in degree C |
| 1.3.6.1.4.1.4756.20.250.20.1.102 | Columnfom04Fx2DDPWRMarginLocal | read-only | current | Local device card fiber port 2 D/D information: Power margin |
| 1.3.6.1.4.1.4756.20.250.20.1.103 | Columnfom04FxFEFLocal | read-only | current | Local device card fiber detected Far End Fault: 0:Undetect 1:Detected |
| 1.3.6.1.4.1.4756.20.251 | Nodefom04RemoteCards | |||
| 1.3.6.1.4.1.4756.20.251.20 | Tablefom04RemoteTable | not-accessible | current | A list of local FRM220-FOM04 series card entries. The number of entries is fom04-No-R. |
| 1.3.6.1.4.1.4756.20.251.20.1 | Rowfom04RemoteEntry | not-accessible | current | An entry containing management information applicable to a particular remote FRM220-FOM04 series card. |
| 1.3.6.1.4.1.4756.20.251.20.1.1 | Columnfom04ChassisIndexRemote | read-only | current | A unique value for each remote card. It is the chassis location number. |
| 1.3.6.1.4.1.4756.20.251.20.1.2 | Columnfom04SlotIndexRemote | read-only | current | A unique value for each remote card. It is the slot location number. |
| 1.3.6.1.4.1.4756.20.251.20.1.3 | Columnfom04CardHWVerRemote | read-only | current | Remote FRM220-FOM04 Series card hardware version x.xxx |
| 1.3.6.1.4.1.4756.20.251.20.1.4 | Columnfom04CardFWVerRemote | read-only | current | Remote FRM220-FOM04 Series card firmware version x.xxx |
| 1.3.6.1.4.1.4756.20.251.20.1.5 | Columnfom04CardCPLDVerRemote | read-only | current | Remote FRM220-FOM04 Series card CPLD version x.xxx |
| 1.3.6.1.4.1.4756.20.251.20.1.6 | Columnfom04CardFPGAVerRemote | read-only | current | Remote FRM220-FOM04 Series card FPGA version x.xxx |
| 1.3.6.1.4.1.4756.20.251.20.1.7 | Columnfom04PortActiveRemote | read-only | current | Remote FRM220-FOM04 Series card active: 0:Disable 1:Enable |
| 1.3.6.1.4.1.4756.20.251.20.1.8 | Columnfom04SettoDefaultRemote | read-write | current | Remote FRM220-FOM04 Series card set to default: 0:OFF 1:Action |
| 1.3.6.1.4.1.4756.20.251.20.1.9 | Columnfom04PortResetRemote | read-write | current | Remote FRM220-FOM04 Series card portreset: 0:OFF 1:Action |
| 1.3.6.1.4.1.4756.20.251.20.1.10 | Columnfom04FxLinkRemote | read-only | current | Remote FRM220-FOM04 fiber link status: 0:Down 1:up |
| 1.3.6.1.4.1.4756.20.251.20.1.11 | Columnfom04FxWorkCHRemote | read-write | current | Remote FRM220-FOM04 fiber work channel: 0:Optical 1 1:Optical 2 |
| 1.3.6.1.4.1.4756.20.251.20.1.12 | Columnfom04Fx1RxLinkRemote | read-only | current | Remote FRM220-FOM04 fiber 1 rx loss status: 0:Down 1:Up |
| 1.3.6.1.4.1.4756.20.251.20.1.13 | Columnfom04Fx2RxLinkRemote | read-only | current | Remote FRM220-FOM04 fiber 1 rx loss status: 0:Down 1:Up |
| 1.3.6.1.4.1.4756.20.251.20.1.14 | Columnfom04FxLBSettingRemote | read-write | current | Remote FRM220-FOM04 loopback mode: 0:Disable 1:LLB 2:RLB |
| 1.3.6.1.4.1.4756.20.251.20.1.15 | Columnfom04Utp1LinkRemote | read-only | current | Remote FRM220-FOM04 UTP 1 link status: 0:Down 1:Up |
| 1.3.6.1.4.1.4756.20.251.20.1.16 | Columnfom04Utp1NegoSTSRemote | read-only | current | Remote FRM220-FOM04 UTP 1 negotiation status: 0:Manual 1:Auto |
| 1.3.6.1.4.1.4756.20.251.20.1.17 | Columnfom04Utp1SpeedSTSRemote | read-only | current | Remote FRM220-FOM04 UTP 1 speed status: 0:10M 1:100M |
| 1.3.6.1.4.1.4756.20.251.20.1.18 | Columnfom04Utp1DuplexSTSRemote | read-only | current | Remote FRM220-FOM04 UTP 1 duplex status: 0:Half 1:Full |
| 1.3.6.1.4.1.4756.20.251.20.1.19 | Columnfom04Utp1ActiveRemote | read-write | current | Remote FRM220-FOM04 UTP 1 port active: 0:Disable 1:Enable |
| 1.3.6.1.4.1.4756.20.251.20.1.20 | Columnfom04Utp1NegoRemote | read-write | current | Remote FRM220-FOM04 UTP 1 negoiation: 0:Manual 1:Auto |
| 1.3.6.1.4.1.4756.20.251.20.1.21 | Columnfom04Utp1SpeedRemote | read-write | current | Remote FRM220-FOM04 UTP 1 speed: 0:On 1:Off |
| 1.3.6.1.4.1.4756.20.251.20.1.22 | Columnfom04Utp1DuplexRemote | read-write | current | Remote FRM220-FOM04 UTP 1 duplex: 0:Half 1:Full |
| 1.3.6.1.4.1.4756.20.251.20.1.23 | Columnfom04Utp2LinkRemote | read-only | current | Remote FRM220-FOM04 UTP 2 link status: 0:Down 1:Up |
| 1.3.6.1.4.1.4756.20.251.20.1.24 | Columnfom04Utp2NegoSTSRemote | read-only | current | Remote FRM220-FOM04 UTP 2 negotiation status: 0:Manual 1:Auto |
| 1.3.6.1.4.1.4756.20.251.20.1.25 | Columnfom04Utp2SpeedSTSRemote | read-only | current | Remote FRM220-FOM04 UTP 2 speed status: 0:10M 1:100M |
| 1.3.6.1.4.1.4756.20.251.20.1.26 | Columnfom04Utp2DuplexSTSRemote | read-only | current | Remote FRM220-FOM04 UTP 2 duplex status: 0:Half 1:Full |
| 1.3.6.1.4.1.4756.20.251.20.1.27 | Columnfom04Utp2ActiveRemote | read-write | current | Remote FRM220-FOM04 UTP 2 port active: 0:Disable 1:Enable |
| 1.3.6.1.4.1.4756.20.251.20.1.28 | Columnfom04Utp2NegoRemote | read-write | current | Remote FRM220-FOM04 UTP 2 negoiation: 0:Manual 1:Auto |
| 1.3.6.1.4.1.4756.20.251.20.1.29 | Columnfom04Utp2SpeedRemote | read-write | current | Remote FRM220-FOM04 UTP 2 speed: 0:On 1:Off |
| 1.3.6.1.4.1.4756.20.251.20.1.30 | Columnfom04Utp2DuplexRemote | read-write | current | Remote FRM220-FOM04 UTP 2 duplex: 0:Half 1:Full |
| 1.3.6.1.4.1.4756.20.251.20.1.31 | Columnfom04Utp3LinkRemote | read-only | current | Remote FRM220-FOM04 UTP 3 link status: 0:Down 1:Up |
| 1.3.6.1.4.1.4756.20.251.20.1.32 | Columnfom04Utp3NegoSTSRemote | read-only | current | Remote FRM220-FOM04 UTP 3 negotiation status: 0:Manual 1:Auto |
| 1.3.6.1.4.1.4756.20.251.20.1.33 | Columnfom04Utp3SpeedSTSRemote | read-only | current | Remote FRM220-FOM04 UTP 3 speed status: 0:10M 1:100M |
| 1.3.6.1.4.1.4756.20.251.20.1.34 | Columnfom04Utp3DuplexSTSRemote | read-only | current | Remote FRM220-FOM04 UTP 3 duplex status: 0:Half 1:Full |
| 1.3.6.1.4.1.4756.20.251.20.1.35 | Columnfom04Utp3ActiveRemote | read-write | current | Remote FRM220-FOM04 UTP 3 port active: 0:Disable 1:Enable |
| 1.3.6.1.4.1.4756.20.251.20.1.36 | Columnfom04Utp3NegoRemote | read-write | current | Remote FRM220-FOM04 UTP 3 negoiation: 0:Manual 1:Auto |
| 1.3.6.1.4.1.4756.20.251.20.1.37 | Columnfom04Utp3SpeedRemote | read-write | current | Remote FRM220-FOM04 UTP 3 speed: 0:On 1:Off |
| 1.3.6.1.4.1.4756.20.251.20.1.38 | Columnfom04Utp3DuplexRemote | read-write | current | Remote FRM220-FOM04 UTP 3 duplex: 0:Half 1:Full |
| 1.3.6.1.4.1.4756.20.251.20.1.39 | Columnfom04RS232ActiveRemote | read-write | current | Remote FRM220-FOM04 RS232 port active: 0:Disable 1:Enable |
| 1.3.6.1.4.1.4756.20.251.20.1.40 | Columnfom04RS232DataActiveRemote | read-only | current | Remote FRM220-FOM04 RS232 Rx active status: 0:OFF 1:ON |
| 1.3.6.1.4.1.4756.20.251.20.1.41 | Columnfom04RS232LBSettingRemote | read-write | current | Remote FRM220-FOM04 RS232 loopback : 0:Disable 1:LLB 2:RLB |
| 1.3.6.1.4.1.4756.20.251.20.1.42 | Columnfom04E1T1TermRemote | read-write | current | Remote FRM220-FOM04 E1T1 termination type: 0:E1/75/BNC 1:E1/120/RJ45 2:T1/100/RJ45 |
| 1.3.6.1.4.1.4756.20.251.20.1.43 | Columnfom04E1T1CH1ActiveRemote | read-write | current | Remote FRM220-FOM04 E1T1 channel 1 port active : 0:Disable 1:Enalbe |
| 1.3.6.1.4.1.4756.20.251.20.1.44 | Columnfom04E1T1CH1LinkRemote | read-only | current | Remote FRM220-FOM04 E1T1 channel 1 link status: 0:Down 1:Up |
| 1.3.6.1.4.1.4756.20.251.20.1.45 | Columnfom04E1T1CH1BVPErrorRemote | read-only | current | Remote FRM220-FOM04 E1T1 channel 1 BVP error status : 0:Normal 1:Error |
| 1.3.6.1.4.1.4756.20.251.20.1.46 | Columnfom04E1T1CH1LineCodeRemote | read-write | current | Remote FRM220-FOM04 E1T1 channel 1 line code: 0:HDB3/B8ZS 1:AMI |
| 1.3.6.1.4.1.4756.20.251.20.1.47 | Columnfom04E1T1CH1ELBRemote | read-write | current | Remote FRM220-FOM04 E1T1 channel 1 E1 loopback: 0:Disable 1:LLB 2:RLB |
| 1.3.6.1.4.1.4756.20.251.20.1.48 | Columnfom04E1T1CH1RcvAISRemote | read-only | current | Remote FRM220-FOM04 E1T1 channel 1 Rev AIS: 0:OFF 1:ON |
| 1.3.6.1.4.1.4756.20.251.20.1.49 | Columnfom04E1T1CH2ActiveRemote | read-write | current | Remote FRM220-FOM04 E1T1 channel 2 port active : 0:Disable 1:Enalbe |
| 1.3.6.1.4.1.4756.20.251.20.1.50 | Columnfom04E1T1CH2LinkRemote | read-only | current | Remote FRM220-FOM04 E1T1 channel 2 link status: 0:Down 1:Up |
| 1.3.6.1.4.1.4756.20.251.20.1.51 | Columnfom04E1T1CH2BVPErrorRemote | read-only | current | Remote FRM220-FOM04 E1T1 channel 2 BVP error status : 0:Normal 1:Error |
| 1.3.6.1.4.1.4756.20.251.20.1.52 | Columnfom04E1T1CH2LineCodeRemote | read-write | current | Remote FRM220-FOM04 E1T1 channel 2 line code: 0:HDB3/B8ZS 1:AMI |
| 1.3.6.1.4.1.4756.20.251.20.1.53 | Columnfom04E1T1CH2ELBRemote | read-write | current | Remote FRM220-FOM04 E1T1 channel 2 E1 loopback: 0:Disable 1:LLB 2:RLB |
| 1.3.6.1.4.1.4756.20.251.20.1.54 | Columnfom04E1T1CH2RcvAISRemote | read-only | current | Remote FRM220-FOM04 E1T1 channel 2 Rev AIS: 0:OFF 1:ON |
| 1.3.6.1.4.1.4756.20.251.20.1.55 | Columnfom04E1T1CH3ActiveRemote | read-write | current | Remote FRM220-FOM04 E1T1 channel 3 port active : 0:Disable 1:Enalbe |
| 1.3.6.1.4.1.4756.20.251.20.1.56 | Columnfom04E1T1CH3LinkRemote | read-only | current | Remote FRM220-FOM04 E1T1 channel 3 link status: 0:Down 1:Up |
| 1.3.6.1.4.1.4756.20.251.20.1.57 | Columnfom04E1T1CH3BVPErrorRemote | read-only | current | Remote FRM220-FOM04 E1T1 channel 3 BVP error status : 0:Normal 1:Error |
| 1.3.6.1.4.1.4756.20.251.20.1.58 | Columnfom04E1T1CH3LineCodeRemote | read-write | current | Remote FRM220-FOM04 E1T1 channel 3 line code: 0:HDB3/B8ZS 1:AMI |
| 1.3.6.1.4.1.4756.20.251.20.1.59 | Columnfom04E1T1CH3ELBRemote | read-write | current | Remote FRM220-FOM04 E1T1 channel 3 E1 loopback: 0:Disable 1:LLB 2:RLB |
| 1.3.6.1.4.1.4756.20.251.20.1.60 | Columnfom04E1T1CH3RcvAISRemote | read-only | current | Remote FRM220-FOM04 E1T1 channel 3 Rev AIS: 0:OFF 1:ON |
| 1.3.6.1.4.1.4756.20.251.20.1.61 | Columnfom04E1T1CH4ActiveRemote | read-write | current | Remote FRM220-FOM04 E1T1 channel 4 port active : 0:Disable 1:Enalbe |
| 1.3.6.1.4.1.4756.20.251.20.1.62 | Columnfom04E1T1CH4LinkRemote | read-only | current | Remote FRM220-FOM04 E1T1 channel 4 link status: 0:Down 1:Up |
| 1.3.6.1.4.1.4756.20.251.20.1.63 | Columnfom04E1T1CH4BVPErrorRemote | read-only | current | Remote FRM220-FOM04 E1T1 channel 4 BVP error status : 0:Normal 1:Error |
| 1.3.6.1.4.1.4756.20.251.20.1.64 | Columnfom04E1T1CH4LineCodeRemote | read-write | current | Remote FRM220-FOM04 E1T1 channel 4 line code: 0:HDB3/B8ZS 1:AMI |
| 1.3.6.1.4.1.4756.20.251.20.1.65 | Columnfom04E1T1CH4ELBRemote | read-write | current | Remote FRM220-FOM04 E1T1 channel 4 E1 loopback: 0:Disable 1:LLB 2:RLB |
| 1.3.6.1.4.1.4756.20.251.20.1.66 | Columnfom04E1T1CH4RcvAISRemote | read-only | current | Remote FRM220-FOM04 E1T1 channel 4 Rev AIS: 0:OFF 1:ON |
| 1.3.6.1.4.1.4756.20.251.20.1.67 | Columnfom04PhoneActiveRemote | read-write | current | Remote FRM220-FOM04 phone port active : 0:Disable 1:Enable |
| 1.3.6.1.4.1.4756.20.251.20.1.68 | Columnfom04CallOutRemote | read-write | current | Remote FRM220-FOM04 call out : 0:OFF 1:ON |
| 1.3.6.1.4.1.4756.20.251.20.1.69 | Columnfom04RemotePWRRemote | read-only | current | Remote FRM220-FOM04 Remote power fail: 0:Ok 1:Abnormal |
| 1.3.6.1.4.1.4756.20.251.20.1.70 | Columnfom04LfpModeRemote | read-write | current | Remote FRM220-FOM04 LFP mode: 0:Disable 1:Enable |
| 1.3.6.1.4.1.4756.20.251.20.1.71 | Columnfom04AlsModeRemote | read-write | current | Remote FRM220-FOM04 ALS mode: 0:Disable 1:Enable |
| 1.3.6.1.4.1.4756.20.251.20.1.72 | Columnfom04SnmpPortRemote | read-write | current | Remote FRM220-FOM04 SNMP VLAN : 0:No VLAN 1:Port 1 VLAN |
| 1.3.6.1.4.1.4756.20.251.20.1.73 | Columnfom04PWR1Remote | read-only | current | Remote FRM220-FOM04 PWR 1 (AC): 0:Fail 1:Ok 2:None |
| 1.3.6.1.4.1.4756.20.251.20.1.74 | Columnfom04PWR2Remote | read-only | current | Remote FRM220-FOM04 PWR 2 (DC): 0:Fail 1:Ok 2:None |
| 1.3.6.1.4.1.4756.20.251.20.1.75 | Columnfom04Fx1DDRemote | read-only | current | Remote device card fiber port 1 Digital Diagnostic function: 0:No 1:Yes |
| 1.3.6.1.4.1.4756.20.251.20.1.76 | Columnfom04Fx1DDVendorRemote | read-only | current | Remote device card fiber port 1 D/D information: Vendor name |
| 1.3.6.1.4.1.4756.20.251.20.1.77 | Columnfom04Fx1DDPartNoRemote | read-only | current | Remote device card fiber port 1 D/D information: Vendor part number |
| 1.3.6.1.4.1.4756.20.251.20.1.78 | Columnfom04Fx1DDFiberTypeRemote | read-only | current | Remote device card fiber port 1 D/D information: Fiber Type |
| 1.3.6.1.4.1.4756.20.251.20.1.79 | Columnfom04Fx1DDWaveLenRemote | read-only | current | Remote device card fiber port 1 D/D information: Wave length |
| 1.3.6.1.4.1.4756.20.251.20.1.80 | Columnfom04Fx1DDWaveLen2Remote | read-only | current | Remote device card fiber port 1 D/D information: Wave length 2 |
| 1.3.6.1.4.1.4756.20.251.20.1.81 | Columnfom04Fx1DDLinkLenRemote | read-only | current | Remote device card fiber port 1 D/D information: Link length |
| 1.3.6.1.4.1.4756.20.251.20.1.82 | Columnfom04Fx1DDLenUnitRemote | read-only | current | Remote device card fiber port 1 D/D information: Length Unit |
| 1.3.6.1.4.1.4756.20.251.20.1.83 | Columnfom04Fx1DDStatusRemote | read-only | current | Remote device card fiber port 1 D/D information: Status Support |
| 1.3.6.1.4.1.4756.20.251.20.1.84 | Columnfom04Fx1DDRxSensRemote | read-only | current | Remote device card fiber port 1 D/D information: Rx Sensitivity |
| 1.3.6.1.4.1.4756.20.251.20.1.85 | Columnfom04Fx1DDTxPWRRemote | read-only | current | Remote device card fiber port 1 D/D information: Tx power |
| 1.3.6.1.4.1.4756.20.251.20.1.86 | Columnfom04Fx1DDRxPWRRemote | read-only | current | Remote device card fiber port 1 D/D information: Rx power |
| 1.3.6.1.4.1.4756.20.251.20.1.87 | Columnfom04Fx1DDTempRemote | read-only | current | Remote device card fiber port 1 D/D information: Temperature in degree C |
| 1.3.6.1.4.1.4756.20.251.20.1.88 | Columnfom04Fx1DDPWRMarginRemote | read-only | current | Remote device card fiber port 1 D/D information: Power margin |
| 1.3.6.1.4.1.4756.20.251.20.1.89 | Columnfom04Fx2DDRemote | read-only | current | Remote device card fiber port 2 Digital Diagnostic function: 0:No 1:Yes |
| 1.3.6.1.4.1.4756.20.251.20.1.90 | Columnfom04Fx2DDVendorRemote | read-only | current | Remote device card fiber port 2 D/D information: Vendor name |
| 1.3.6.1.4.1.4756.20.251.20.1.91 | Columnfom04Fx2DDPartNoRemote | read-only | current | Remote device card fiber port 2 D/D information: Vendor part number |
| 1.3.6.1.4.1.4756.20.251.20.1.92 | Columnfom04Fx2DDFiberTypeRemote | read-only | current | Remote device card fiber port 2 D/D information: Fiber Type |
| 1.3.6.1.4.1.4756.20.251.20.1.93 | Columnfom04Fx2DDWaveLenRemote | read-only | current | Remote device card fiber port 2 D/D information: Wave length |
| 1.3.6.1.4.1.4756.20.251.20.1.94 | Columnfom04Fx2DDWaveLen2Remote | read-only | current | Remote device card fiber port 2 D/D information: Wave length 2 |
| 1.3.6.1.4.1.4756.20.251.20.1.95 | Columnfom04Fx2DDLinkLenRemote | read-only | current | Remote device card fiber port 2 D/D information: Link length |
| 1.3.6.1.4.1.4756.20.251.20.1.96 | Columnfom04Fx2DDLenUnitRemote | read-only | current | Remote device card fiber port 2 D/D information: Length Unit |
| 1.3.6.1.4.1.4756.20.251.20.1.97 | Columnfom04Fx2DDStatusRemote | read-only | current | Remote device card fiber port 2 D/D information: Status Support |
| 1.3.6.1.4.1.4756.20.251.20.1.98 | Columnfom04Fx2DDRxSensRemote | read-only | current | Remote device card fiber port 2 D/D information: Rx Sensitivity |
| 1.3.6.1.4.1.4756.20.251.20.1.99 | Columnfom04Fx2DDTxPWRRemote | read-only | current | Remote device card fiber port 2 D/D information: Tx power |
| 1.3.6.1.4.1.4756.20.251.20.1.100 | Columnfom04Fx2DDRxPWRRemote | read-only | current | Remote device card fiber port 2 D/D information: Rx power |
| 1.3.6.1.4.1.4756.20.251.20.1.101 | Columnfom04Fx2DDTempRemote | read-only | current | Remote device card fiber port 2 D/D information: Temperature in degree C |
| 1.3.6.1.4.1.4756.20.251.20.1.102 | Columnfom04Fx2DDPWRMarginRemote | read-only | current | Remote device card fiber port 2 D/D information: Power margin |
| 1.3.6.1.4.1.4756.20.251.20.1.103 | Columnfom04FxFEFRemote | read-only | current | Remote device card fiber detected Far End Fault: 0:Undetect 1:Detected |
| 1.3.6.1.4.1.4756.20.260 | Nodef2R4GCards | |||
| 1.3.6.1.4.1.4756.20.260.20 | Tablef2R4GTable | not-accessible | current | A list of local FRM220-2R4G card entries. The number of entries is f2R4G-No-L. |
| 1.3.6.1.4.1.4756.20.260.20.1 | Rowf2R4GEntry | not-accessible | current | An entry containing management information applicable to a particular local FRM220-3R27G card. |
| 1.3.6.1.4.1.4756.20.260.20.1.1 | Columnf2R4GChassisIndex | read-only | current | A unique value for each local card. It is the chassis location number. |
| 1.3.6.1.4.1.4756.20.260.20.1.2 | Columnf2R4GSlotIndex | read-only | current | A unique value for each local card. It is the slot location number. |
| 1.3.6.1.4.1.4756.20.260.20.1.3 | Columnf2R4GCardHWVer | read-only | current | Local FRM220-2R4G card hardware version x.xxx |
| 1.3.6.1.4.1.4756.20.260.20.1.4 | Columnf2R4GCardFWVer | read-only | current | Local FRM220-2R4G card firmware version x.xxx |
| 1.3.6.1.4.1.4756.20.260.20.1.5 | Columnf2R4GCardCPLDVer | read-only | current | Local FRM220-2R4G card CPLD version x.xxx |
| 1.3.6.1.4.1.4756.20.260.20.1.6 | Columnf2R4GCardFPGAVer | read-only | current | Local FRM220-2R4G card FPGA version x.xxx |
| 1.3.6.1.4.1.4756.20.260.20.1.7 | Columnf2R4GModel | read-only | current | Local CardType: 0:FRM220-2R4G/2S 1:FRM220-2R4G/3S |
| 1.3.6.1.4.1.4756.20.260.20.1.8 | Columnf2R4GDeviceActive | read-write | current | Local FRM220-2R4G card active: 0:Inactive 1:Active |
| 1.3.6.1.4.1.4756.20.260.20.1.9 | Columnf2R4GFx1Link | read-only | current | Local FRM220-2R4G card Fiber1 link status: 0:Down 1:Up |
| 1.3.6.1.4.1.4756.20.260.20.1.10 | Columnf2R4GFx2Link | read-only | current | Local FRM220-2R4G card Fiber2 link status: 0:Down 1:Up |
| 1.3.6.1.4.1.4756.20.260.20.1.11 | Columnf2R4GFx3Link | read-only | current | Local FRM220-2R4G card Fiber3 link status: 0:Down 1:Up |
| 1.3.6.1.4.1.4756.20.260.20.1.12 | Columnf2R4GFx1TxFail | read-only | current | Local FRM220-2R4G card Fiber1 Transceiver Tx Detect: 0:Normal 1:Fail |
| 1.3.6.1.4.1.4756.20.260.20.1.13 | Columnf2R4GFx2TxFail | read-only | current | Local FRM220-2R4G card Fiber2 Transceiver Tx Detect: 0:Normal 1:Fail |
| 1.3.6.1.4.1.4756.20.260.20.1.14 | Columnf2R4GFx3TxFail | read-only | current | Local FRM220-2R4G card Fiber3 Transceiver Tx Detect: 0:Normal 1:Fail |
| 1.3.6.1.4.1.4756.20.260.20.1.15 | Columnf2R4GFx1AlsMode | read-write | current | Local FRM220-2R4G card Fiber1 Auto Laser Showdown: 0:Disable 1:Enable |
| 1.3.6.1.4.1.4756.20.260.20.1.16 | Columnf2R4GFx2AlsMode | read-write | current | Local FRM220-2R4G card Fiber2 Auto Laser Showdown: 0:Disable 1:Enable |
| 1.3.6.1.4.1.4756.20.260.20.1.17 | Columnf2R4GFx3AlsMode | read-write | current | Local FRM220-2R4G card Fiber3 Auto Laser Showdown: 0:Disable 1:Enable |
| 1.3.6.1.4.1.4756.20.260.20.1.18 | Columnf2R4GPortReset | read-write | current | Force local FRM220-2R4G card to reset mode: 0:Off 1:Action |
| 1.3.6.1.4.1.4756.20.260.20.1.19 | Columnf2R4GActivePath | read-write | current | Local FRM220-2R4G card Active Protection Path: 0:Primary 1:Secondary |
| 1.3.6.1.4.1.4756.20.260.20.1.20 | Columnf2R4GOpticFxPro | read-write | current | Local FRM220-2R4G card Optic Fiber Protection: 0:Manual 1:Auto 2:Semi-Auto |
| 1.3.6.1.4.1.4756.20.260.20.1.21 | Columnf2R4GLbsetting | read-write | current | Local FRM220-2R4G card Loopback Test: 0:Disable 1:Line side enable 2:Primary and Secondary side enable 3:All enable |
| 1.3.6.1.4.1.4756.20.260.20.1.22 | Columnf2R4GLossPropagation | read-write | current | Local FRM220-2R4G card Link Fault Pass-through: 0:Disable 1:Enable |
| 1.3.6.1.4.1.4756.20.260.20.1.23 | Columnf2R4GSetToDefault | read-write | current | Local FRM220-2R4G card set to default: 0:OFF 1:Action |
| 1.3.6.1.4.1.4756.20.260.20.1.24 | Columnf2R4GFx1DD | read-only | current | Local FRM220-2R4G card fiber Digital Diagnostic function: 0:No 1:Yes |
| 1.3.6.1.4.1.4756.20.260.20.1.25 | Columnf2R4GFx1DDVendor | read-only | current | Local FRM220-2R4G card fiber D/D information: Vendor name |
| 1.3.6.1.4.1.4756.20.260.20.1.26 | Columnf2R4GFx1DDPartNo | read-only | current | Local FRM220-2R4G card fiber D/D information: Vendor part number |
| 1.3.6.1.4.1.4756.20.260.20.1.27 | Columnf2R4GFx1DDVendorSN | read-only | current | Local FRM220-2R4G card fiber1 D/D information: Vendor serial number |
| 1.3.6.1.4.1.4756.20.260.20.1.28 | Columnf2R4GFx1DDFiberType | read-only | current | Local FRM220-2R4G card fiber D/D information: Fiber Type |
| 1.3.6.1.4.1.4756.20.260.20.1.29 | Columnf2R4GFx1DDWaveLen | read-only | current | Local FRM220-2R4G card fiber D/D information: Wave length |
| 1.3.6.1.4.1.4756.20.260.20.1.30 | Columnf2R4GFx1DDWaveLen2 | read-only | current | Local FRM220-2R4G card fiber D/D information: Wave length 2 |
| 1.3.6.1.4.1.4756.20.260.20.1.31 | Columnf2R4GFx1DDLinkLen | read-only | current | Local FRM220-2R4G card fiber D/D information: Link length |
| 1.3.6.1.4.1.4756.20.260.20.1.32 | Columnf2R4GFx1DDLenUnit | read-only | current | Local FRM220-2R4G card fiber D/D information: Length Unit |
| 1.3.6.1.4.1.4756.20.260.20.1.33 | Columnf2R4GFx1DDStatus | read-only | current | Local FRM220-2R4G card fiber D/D information: Status Support |
| 1.3.6.1.4.1.4756.20.260.20.1.34 | Columnf2R4GFx1DDRxSens | read-only | current | Local FRM220-2R4G card fiber D/D information: Rx Sensitivity |
| 1.3.6.1.4.1.4756.20.260.20.1.35 | Columnf2R4GFx1DDTxPWR | read-only | current | Local FRM220-2R4G card fiber D/D information: Tx power |
| 1.3.6.1.4.1.4756.20.260.20.1.36 | Columnf2R4GFx1DDRxPWR | read-only | current | Local FRM220-2R4G card fiber D/D information: Rx power |
| 1.3.6.1.4.1.4756.20.260.20.1.37 | Columnf2R4GFx1DDTemp | read-only | current | Local FRM220-2R4G card fiber D/D information: Temperature in degree C |
| 1.3.6.1.4.1.4756.20.260.20.1.38 | Columnf2R4GFx1DDPWRMargin | read-only | current | Local FRM220-2R4G card fiber D/D information: Power margin |
| 1.3.6.1.4.1.4756.20.260.20.1.39 | Columnf2R4GFx2DD | read-only | current | Local FRM220-2R4G card fiber2 Digital Diagnostic function: 0:No 1:Yes |
| 1.3.6.1.4.1.4756.20.260.20.1.40 | Columnf2R4GFx2DDVendor | read-only | current | Local FRM220-2R4G card fiber2 D/D information: Vendor name |
| 1.3.6.1.4.1.4756.20.260.20.1.41 | Columnf2R4GFx2DDPartNo | read-only | current | Local FRM220-2R4G card fiber2 D/D information: Vendor part number |
| 1.3.6.1.4.1.4756.20.260.20.1.42 | Columnf2R4GFx2DDVendorSN | read-only | current | Local FRM220-2R4G card fiber2 D/D information: Vendor serial number |
| 1.3.6.1.4.1.4756.20.260.20.1.43 | Columnf2R4GFx2DDFiberType | read-only | current | Local FRM220-2R4G card fiber2 D/D information: Fiber Type |
| 1.3.6.1.4.1.4756.20.260.20.1.44 | Columnf2R4GFx2DDWaveLen | read-only | current | Local FRM220-2R4G card fiber2 D/D information: Wave length |
| 1.3.6.1.4.1.4756.20.260.20.1.45 | Columnf2R4GFx2DDWaveLen2 | read-only | current | Local FRM220-2R4G card fiber2 D/D information: Wave length 2 |
| 1.3.6.1.4.1.4756.20.260.20.1.46 | Columnf2R4GFx2DDLinkLen | read-only | current | Local FRM220-2R4G card fiber2 D/D information: Link length |
| 1.3.6.1.4.1.4756.20.260.20.1.47 | Columnf2R4GFx2DDLenUnit | read-only | current | Local FRM220-2R4G card fiber2 D/D information: Length Unit |
| 1.3.6.1.4.1.4756.20.260.20.1.48 | Columnf2R4GFx2DDStatus | read-only | current | Local FRM220-2R4G card fiber2 D/D information: Status Support |
| 1.3.6.1.4.1.4756.20.260.20.1.49 | Columnf2R4GFx2DDRxSens | read-only | current | Local FRM220-2R4G card fiber2 D/D information: Rx Sensitivity |
| 1.3.6.1.4.1.4756.20.260.20.1.50 | Columnf2R4GFx2DDTxPWR | read-only | current | Local FRM220-2R4G card fiber2 D/D information: Tx power |
| 1.3.6.1.4.1.4756.20.260.20.1.51 | Columnf2R4GFx2DDRxPWR | read-only | current | Local FRM220-2R4G card fiber2 D/D information: Rx power |
| 1.3.6.1.4.1.4756.20.260.20.1.52 | Columnf2R4GFx2DDTemp | read-only | current | Local FRM220-2R4G card fiber2 D/D information: Temperature in degree C |
| 1.3.6.1.4.1.4756.20.260.20.1.53 | Columnf2R4GFx2DDPWRMargin | read-only | current | Local FRM220-2R4G card fiber2 D/D information: Power margin |
| 1.3.6.1.4.1.4756.20.260.20.1.54 | Columnf2R4GFx3DD | read-only | current | Local FRM220-2R4G card fiber3 Digital Diagnostic function: 0:No 1:Yes |
| 1.3.6.1.4.1.4756.20.260.20.1.55 | Columnf2R4GFx3DDVendor | read-only | current | Local FRM220-2R4G card fiber3 D/D information: Vendor name |
| 1.3.6.1.4.1.4756.20.260.20.1.56 | Columnf2R4GFx3DDPartNo | read-only | current | Local FRM220-2R4G card fiber3 D/D information: Vendor part number |
| 1.3.6.1.4.1.4756.20.260.20.1.57 | Columnf2R4GFx3DDVendorSN | read-only | current | Local FRM220-2R4G card fiber3 D/D information: Vendor serial number |
| 1.3.6.1.4.1.4756.20.260.20.1.58 | Columnf2R4GFx3DDFiberType | read-only | current | Local FRM220-2R4G card fiber3 D/D information: Fiber Type |
| 1.3.6.1.4.1.4756.20.260.20.1.59 | Columnf2R4GFx3DDWaveLen | read-only | current | Local FRM220-2R4G card fiber3 D/D information: Wave length |
| 1.3.6.1.4.1.4756.20.260.20.1.60 | Columnf2R4GFx3DDWaveLen2 | read-only | current | Local FRM220-2R4G card fiber3 D/D information: Wave length 2 |
| 1.3.6.1.4.1.4756.20.260.20.1.61 | Columnf2R4GFx3DDLinkLen | read-only | current | Local FRM220-2R4G card fiber3 D/D information: Link length |
| 1.3.6.1.4.1.4756.20.260.20.1.62 | Columnf2R4GFx3DDLenUnit | read-only | current | Local FRM220-2R4G card fiber3 D/D information: Length Unit |
| 1.3.6.1.4.1.4756.20.260.20.1.63 | Columnf2R4GFx3DDStatus | read-only | current | Local FRM220-2R4G card fiber3 D/D information: Status Support |
| 1.3.6.1.4.1.4756.20.260.20.1.64 | Columnf2R4GFx3DDRxSens | read-only | current | Local FRM220-2R4G card fiber3 D/D information: Rx Sensitivity |
| 1.3.6.1.4.1.4756.20.260.20.1.65 | Columnf2R4GFx3DDTxPWR | read-only | current | Local FRM220-2R4G card fiber3 D/D information: Tx power |
| 1.3.6.1.4.1.4756.20.260.20.1.66 | Columnf2R4GFx3DDRxPWR | read-only | current | Local FRM220-2R4G card fiber3 D/D information: Rx power |
| 1.3.6.1.4.1.4756.20.260.20.1.67 | Columnf2R4GFx3DDTemp | read-only | current | Local FRM220-2R4G card fiber3 D/D information: Temperature in degree C |
| 1.3.6.1.4.1.4756.20.260.20.1.68 | Columnf2R4GFx3DDPWRMargin | read-only | current | Local FRM220-2R4G card fiber3 D/D information: Power margin |
| 1.3.6.1.4.1.4756.20.270 | Nodef10GCards | |||
| 1.3.6.1.4.1.4756.20.270.20 | Tablef10GTable | not-accessible | current | A list of local FRM220-10G card entries. The number of entries is f10G-No-L. |
| 1.3.6.1.4.1.4756.20.270.20.1 | Rowf10GEntry | not-accessible | current | An entry containing management information applicable to a particular local FRM220-10G card. |
| 1.3.6.1.4.1.4756.20.270.20.1.1 | Columnf10GChassisIndex | read-only | current | A unique value for each local card. It is the chassis location number. |
| 1.3.6.1.4.1.4756.20.270.20.1.2 | Columnf10GSlotIndex | read-only | current | A unique value for each local card. It is the slot location number. |
| 1.3.6.1.4.1.4756.20.270.20.1.3 | Columnf10GCardHWVer | read-only | current | Local FRM220-10G card hardware version x.xxx |
| 1.3.6.1.4.1.4756.20.270.20.1.4 | Columnf10GCardFWVer | read-only | current | Local FRM220-10G card firmware version x.xxx |
| 1.3.6.1.4.1.4756.20.270.20.1.5 | Columnf10GCardCPLDVer | read-only | current | Local FRM220-10G card CPLD version x.xxx |
| 1.3.6.1.4.1.4756.20.270.20.1.6 | Columnf10GCardFPGAVer | read-only | current | Local FRM220-10G card FPGA version x.xxx |
| 1.3.6.1.4.1.4756.20.270.20.1.7 | Columnf10GModel | read-only | current | Local CardType: 0:FRM220-10G/SXX 1:FRM220-10G/SX 2:FRM220-10G/XX |
| 1.3.6.1.4.1.4756.20.270.20.1.8 | Columnf10GDeviceActive | read-write | current | Local FRM220-10G card active: 0:Inactive 1:Active |
| 1.3.6.1.4.1.4756.20.270.20.1.9 | Columnf10GFx1Link | read-only | current | Local FRM220-10G card Fiber1 link status: 0:Down 1:Up |
| 1.3.6.1.4.1.4756.20.270.20.1.10 | Columnf10GFx2Link | read-only | current | Local FRM220-10G card Fiber2 link status: 0:Down 1:Up |
| 1.3.6.1.4.1.4756.20.270.20.1.11 | Columnf10GFx3Link | read-only | current | Local FRM220-10G card Fiber3 link status: 0:Down 1:Up |
| 1.3.6.1.4.1.4756.20.270.20.1.12 | Columnf10GFx1CDRLocked | read-only | current | Local FRM220-10G card Fiber1 CRD Locked: 0:Not Locked 1:Locked |
| 1.3.6.1.4.1.4756.20.270.20.1.13 | Columnf10GFx2CDRLocked | read-only | current | Local FRM220-10G card Fiber2 CRD Locked: 0:Not Locked 1:Locked |
| 1.3.6.1.4.1.4756.20.270.20.1.14 | Columnf10GFx3CDRLocked | read-only | current | Local FRM220-10G card Fiber3 CRD Locked: 0:Not Locked 1:Locked |
| 1.3.6.1.4.1.4756.20.270.20.1.15 | Columnf10GFx1LossPropagation | read-write | current | Local FRM220-10G card Fiber1 Loss Propagation: 0:Disable 1:Enable |
| 1.3.6.1.4.1.4756.20.270.20.1.16 | Columnf10GFx2andFx3LossPropagation | read-write | current | Local FRM220-10G card Fiber2 and Fiber3 Loss Propagation: 0:Disable 1:Enable |
| 1.3.6.1.4.1.4756.20.270.20.1.17 | Columnf10GFx1AlsMode | read-write | current | Local FRM220-10G card Fiber1 Auto Laser Showdown: 0:Disable 1:Enable |
| 1.3.6.1.4.1.4756.20.270.20.1.18 | Columnf10GFx2AlsMode | read-write | current | Local FRM220-10G card Fiber2 Auto Laser Showdown: 0:Disable 1:Enable |
| 1.3.6.1.4.1.4756.20.270.20.1.19 | Columnf10GFx3AlsMode | read-write | current | Local FRM220-10G card Fiber3 Auto Laser Showdown: 0:Disable 1:Enable |
| 1.3.6.1.4.1.4756.20.270.20.1.20 | Columnf10GPortReset | read-write | current | Force local FRM220-10G card to reset mode: 0:Off 1:Action |
| 1.3.6.1.4.1.4756.20.270.20.1.21 | Columnf10GSetDefault | read-write | current | Local FRM220-10G card set to default : 0:Off 1:Action |
| 1.3.6.1.4.1.4756.20.270.20.1.22 | Columnf10GSystemOK | read-only | current | Local FRM220-10G card system status: 0:Failure 1:Ok |
| 1.3.6.1.4.1.4756.20.270.20.1.23 | Columnf10GFx1Lbsetting | read-write | current | Local FRM220-10G card Fiber1 Loopback: 0:Off 1:On |
| 1.3.6.1.4.1.4756.20.270.20.1.24 | Columnf10GFx2Lbsetting | read-write | current | Local FRM220-10G card Fiber1 Loopback: 0:Off 1:On |
| 1.3.6.1.4.1.4756.20.270.20.1.25 | Columnf10GFx3Lbsetting | read-write | current | Local FRM220-10G card Fiber3 Loopback: 0:Off 1:On |
| 1.3.6.1.4.1.4756.20.270.20.1.26 | Columnf10GLbEnable | read-write | current | Local FRM220-10G card Loopback mode: 0:Disable 1:Enable |
| 1.3.6.1.4.1.4756.20.270.20.1.27 | Columnf10GBaudRate | read-write | current | Local FRM220-10G card BaudRate: 0:10G Ethernet 1:10G Fiber Channel 2:OC-192/STM-64 3:G.709 OTU2 4:1G Fiber Channel 5:2G Fiber Channel 6:4G Fiber Channel 7:8G F… |
| 1.3.6.1.4.1.4756.20.270.20.1.28 | Columnf10GOpticFxPro | read-write | current | Local FRM220-10G card optic fiber protection: 0:Manual 1:Auto 2:Semi-Auto 3:Pri to Sec |
| 1.3.6.1.4.1.4756.20.270.20.1.29 | Columnf10GActivePath | read-write | current | Local FRM220-10G card Loopback mode: 0:Primary 1:Second |
| 1.3.6.1.4.1.4756.20.270.20.1.30 | Columnf10GFx1LinkAlarm | read-write | current | Local FRM220-10G card Fx1 Link Alarm: 0:Disalbe 1:Enable |
| 1.3.6.1.4.1.4756.20.270.20.1.31 | Columnf10GFx2LinkAlarm | read-write | current | Local FRM220-10G card Fx2 Link Alarm: 0:Disalbe 1:Enable |
| 1.3.6.1.4.1.4756.20.270.20.1.32 | Columnf10GFx3LinkAlarm | read-write | current | Local FRM220-10G card Fx3 Link Alarm: 0:Disalbe 1:Enable |
| 1.3.6.1.4.1.4756.20.270.20.1.33 | Columnf10GFx1DD | read-only | current | Local FRM220-10G card fiber Digital Diagnostic function: 0:No 1:Yes |
| 1.3.6.1.4.1.4756.20.270.20.1.34 | Columnf10GFx1DDVendor | read-only | current | Local FRM220-10G card fiber D/D information: Vendor name |
| 1.3.6.1.4.1.4756.20.270.20.1.35 | Columnf10GFx1DDPartNo | read-only | current | Local FRM220-10G card fiber D/D information: Vendor part number |
| 1.3.6.1.4.1.4756.20.270.20.1.36 | Columnf10GFx1DDFiberType | read-only | current | Local FRM220-10G card fiber D/D information: Fiber Type |
| 1.3.6.1.4.1.4756.20.270.20.1.37 | Columnf10GFx1DDWaveLen | read-only | current | Local FRM220-10G card fiber D/D information: Wave length |
| 1.3.6.1.4.1.4756.20.270.20.1.38 | Columnf10GFx1DDWaveLen2 | read-only | current | Local FRM220-10G card fiber D/D information: Wave length 2 |
| 1.3.6.1.4.1.4756.20.270.20.1.39 | Columnf10GFx1DDLinkLen | read-only | current | Local FRM220-10G card fiber D/D information: Link length |
| 1.3.6.1.4.1.4756.20.270.20.1.40 | Columnf10GFx1DDLenUnit | read-only | current | Local FRM220-10G card fiber D/D information: Length Unit |
| 1.3.6.1.4.1.4756.20.270.20.1.41 | Columnf10GFx1DDStatus | read-only | current | Local FRM220-10G card fiber D/D information: Status Support |
| 1.3.6.1.4.1.4756.20.270.20.1.42 | Columnf10GFx1DDRxSens | read-only | current | Local FRM220-10G card fiber D/D information: Rx Sensitivity |
| 1.3.6.1.4.1.4756.20.270.20.1.43 | Columnf10GFx1DDTxPWR | read-only | current | Local FRM220-10G card fiber D/D information: Tx power |
| 1.3.6.1.4.1.4756.20.270.20.1.44 | Columnf10GFx1DDRxPWR | read-only | current | Local FRM220-10G card fiber D/D information: Rx power |
| 1.3.6.1.4.1.4756.20.270.20.1.45 | Columnf10GFx1DDTemp | read-only | current | Local FRM220-10G card fiber D/D information: Temperature in degree C |
| 1.3.6.1.4.1.4756.20.270.20.1.46 | Columnf10GFx1DDPWRMargin | read-only | current | Local FRM220-10G card fiber D/D information: Power margin |
| 1.3.6.1.4.1.4756.20.270.20.1.47 | Columnf10GFx2DD | read-only | current | Local FRM220-10G card fiber2 Digital Diagnostic function: 0:No 1:Yes |
| 1.3.6.1.4.1.4756.20.270.20.1.48 | Columnf10GFx2DDVendor | read-only | current | Local FRM220-10G card fiber2 D/D information: Vendor name |
| 1.3.6.1.4.1.4756.20.270.20.1.49 | Columnf10GFx2DDPartNo | read-only | current | Local FRM220-10G card fiber2 D/D information: Vendor part number |
| 1.3.6.1.4.1.4756.20.270.20.1.50 | Columnf10GFx2DDFiberType | read-only | current | Local FRM220-10G card fiber2 D/D information: Fiber Type |
| 1.3.6.1.4.1.4756.20.270.20.1.51 | Columnf10GFx2DDWaveLen | read-only | current | Local FRM220-10G card fiber2 D/D information: Wave length |
| 1.3.6.1.4.1.4756.20.270.20.1.52 | Columnf10GFx2DDWaveLen2 | read-only | current | Local FRM220-10G card fiber2 D/D information: Wave length 2 |
| 1.3.6.1.4.1.4756.20.270.20.1.53 | Columnf10GFx2DDLinkLen | read-only | current | Local FRM220-10G card fiber2 D/D information: Link length |
| 1.3.6.1.4.1.4756.20.270.20.1.54 | Columnf10GFx2DDLenUnit | read-only | current | Local FRM220-10G card fiber2 D/D information: Length Unit |
| 1.3.6.1.4.1.4756.20.270.20.1.55 | Columnf10GFx2DDStatus | read-only | current | Local FRM220-10G card fiber2 D/D information: Status Support |
| 1.3.6.1.4.1.4756.20.270.20.1.56 | Columnf10GFx2DDRxSens | read-only | current | Local FRM220-10G card fiber2 D/D information: Rx Sensitivity |
| 1.3.6.1.4.1.4756.20.270.20.1.57 | Columnf10GFx2DDTxPWR | read-only | current | Local FRM220-10G card fiber2 D/D information: Tx power |
| 1.3.6.1.4.1.4756.20.270.20.1.58 | Columnf10GFx2DDRxPWR | read-only | current | Local FRM220-10G card fiber2 D/D information: Rx power |
| 1.3.6.1.4.1.4756.20.270.20.1.59 | Columnf10GFx2DDTemp | read-only | current | Local FRM220-10G card fiber2 D/D information: Temperature in degree C |
| 1.3.6.1.4.1.4756.20.270.20.1.60 | Columnf10GFx2DDPWRMargin | read-only | current | Local FRM220-10G card fiber2 D/D information: Power margin |
| 1.3.6.1.4.1.4756.20.270.20.1.61 | Columnf10GFx3DD | read-only | current | Local FRM220-10G card fiber Digital Diagnostic function: 0:No 1:Yes |
| 1.3.6.1.4.1.4756.20.270.20.1.62 | Columnf10GFx3DDVendor | read-only | current | Local FRM220-10G card fiber D/D information: Vendor name |
| 1.3.6.1.4.1.4756.20.270.20.1.63 | Columnf10GFx3DDPartNo | read-only | current | Local FRM220-10G card fiber D/D information: Vendor part number |
| 1.3.6.1.4.1.4756.20.270.20.1.64 | Columnf10GFx3DDFiberType | read-only | current | Local FRM220-10G card fiber D/D information: Fiber Type |
| 1.3.6.1.4.1.4756.20.270.20.1.65 | Columnf10GFx3DDWaveLen | read-only | current | Local FRM220-10G card fiber D/D information: Wave length |
| 1.3.6.1.4.1.4756.20.270.20.1.66 | Columnf10GFx3DDWaveLen2 | read-only | current | Local FRM220-10G card fiber D/D information: Wave length 2 |
| 1.3.6.1.4.1.4756.20.270.20.1.67 | Columnf10GFx3DDLinkLen | read-only | current | Local FRM220-10G card fiber D/D information: Link length |
| 1.3.6.1.4.1.4756.20.270.20.1.68 | Columnf10GFx3DDLenUnit | read-only | current | Local FRM220-10G card fiber D/D information: Length Unit |
| 1.3.6.1.4.1.4756.20.270.20.1.69 | Columnf10GFx3DDStatus | read-only | current | Local FRM220-10G card fiber D/D information: Status Support |
| 1.3.6.1.4.1.4756.20.270.20.1.70 | Columnf10GFx3DDRxSens | read-only | current | Local FRM220-10G card fiber D/D information: Rx Sensitivity |
| 1.3.6.1.4.1.4756.20.270.20.1.71 | Columnf10GFx3DDTxPWR | read-only | current | Local FRM220-10G card fiber D/D information: Tx power |
| 1.3.6.1.4.1.4756.20.270.20.1.72 | Columnf10GFx3DDRxPWR | read-only | current | Local FRM220-10G card fiber D/D information: Rx power |
| 1.3.6.1.4.1.4756.20.270.20.1.73 | Columnf10GFx3DDTemp | read-only | current | Local FRM220-10G card fiber D/D information: Temperature in degree C |
| 1.3.6.1.4.1.4756.20.270.20.1.74 | Columnf10GFx3DDPWRMargin | read-only | current | Local FRM220-10G card fiber D/D information: Power margin |
| 1.3.6.1.4.1.4756.20.270.20.1.75 | Columnf10GBertLineTxMode | read-write | current | Local 10G-SXX card BERTLine Tx Mode: 0:Disable 1:Enable |
| 1.3.6.1.4.1.4756.20.270.20.1.76 | Columnf10GBertLineTxPattern | read-write | current | Local 10G-SXX card BERT Line Tx Pattern: 0:PRBS 7 1:PRBS 9 2:PRBS 23 3:PRBS 31 4:Pass-Through |
| 1.3.6.1.4.1.4756.20.270.20.1.77 | Columnf10GBertLineTxPolarity | read-write | current | Local 10G-SXX card BERT Line Tx Polarity: 0:Normal 1:invert |
| 1.3.6.1.4.1.4756.20.270.20.1.78 | Columnf10GBertLineRxMode | read-write | current | Local 10G-SXX card BERT Line Rx Mode: 0:Disable 1:Enable |
| 1.3.6.1.4.1.4756.20.270.20.1.79 | Columnf10GBertLineRxPattern | read-write | current | Local 10G-SXX card BERT Line Rx Pattern: 0:PRBS 7 1:PRBS 9 2:PRBS 23 3:PRBS 31 |
| 1.3.6.1.4.1.4756.20.270.20.1.80 | Columnf10GBertLineRxPolarity | read-write | current | Local 10G-SXX card BERT Line Rx Polarity: 0:Normal 1:invert |
| 1.3.6.1.4.1.4756.20.270.20.1.81 | Columnf10GBertLineRxPatternStatus | read-only | current | Local 10G-SXX card BERT Line Rx Pattern Status: 0:Loss 1:Sync |
| 1.3.6.1.4.1.4756.20.270.20.1.82 | Columnf10GBertLineRxErrorCounter | read-only | current | Local 10G-SXX card BERT Line Rx Error Counter. |
| 1.3.6.1.4.1.4756.20.270.20.1.83 | Columnf10GBertLineClrErrorCounter | read-write | current | Local 10G-SXX card BERT Line Clear Rx Error counter. |
| 1.3.6.1.4.1.4756.20.270.20.1.84 | Columnf10GBertClientTxMode | read-write | current | Local 10G-SXX card BERT Client Tx Mode: 0:Disable 1:Enable |
| 1.3.6.1.4.1.4756.20.270.20.1.85 | Columnf10GBertClientTxPattern | read-write | current | Local 10G-SXX card BERT Client Tx Pattern: 0:PRBS 7 1:PRBS 9 2:PRBS 23 3:PRBS 31 4:Pass-Through |
| 1.3.6.1.4.1.4756.20.270.20.1.86 | Columnf10GBertClientTxPolarity | read-write | current | Local 10G-SXX card BERT Client Tx Polarity: 0:Normal 1:invert |
| 1.3.6.1.4.1.4756.20.270.20.1.87 | Columnf10GBertClientRxMode | read-write | current | Local 10G-SXX card BERT Client Rx Mode: 0:Disable 1:Enable |
| 1.3.6.1.4.1.4756.20.270.20.1.88 | Columnf10GBertClientRxPattern | read-write | current | Local 10G-SXX card BERT Client Rx Pattern: 0:PRBS 7 1:PRBS 9 2:PRBS 23 3:PRBS 31 |
| 1.3.6.1.4.1.4756.20.270.20.1.89 | Columnf10GBertClientRxPolarity | read-write | current | Local 10G-SXX card BERT Client Rx Polarity: 0:Normal 1:invert |
| 1.3.6.1.4.1.4756.20.270.20.1.90 | Columnf10GBertClientRxPatternStatus | read-only | current | Local 10G-SXX card BERT Client Rx Pattern Status: 0:Loss 1:Sync |
| 1.3.6.1.4.1.4756.20.270.20.1.91 | Columnf10GBertClientRxErrorCounter | read-only | current | Local 10G-SXX card BERT Client Rx Error Counter. |
| 1.3.6.1.4.1.4756.20.270.20.1.92 | Columnf10GBertClientClrErrorCounter | read-write | current | Local 10G-SXX card BERT Client Clear Rx Error counter. |
| 1.3.6.1.4.1.4756.20.270.20.1.93 | Columnf10GXFP2WaveLengthStatus | read-only | current | Local 10G-SXX card Tunable XFP2 Wavelength Status: 0:Normal 1:Abnormal |
| 1.3.6.1.4.1.4756.20.270.20.1.94 | Columnf10GXFP3WaveLengthStatus | read-only | current | Local 10G-SXX card Tunable XFP3 Wavelength Status: 0:Normal 1:Abnormal |
| 1.3.6.1.4.1.4756.20.270.20.1.95 | Columnf10GXFP2TemperatureStatus | read-only | current | Local 10G-SXX card Tunable XFP2 Temperature Status: 0:Normal 1:Abnormal |
| 1.3.6.1.4.1.4756.20.270.20.1.96 | Columnf10GXFP3TemperatureStatus | read-only | current | Local 10G-SXX card Tunable XFP3 Temperature Status: 0:Normal 1:Abnormal |
| 1.3.6.1.4.1.4756.20.270.20.1.97 | Columnf10GXFP2TemperaturAlarm | read-write | current | Local 10G-SXX card XFP2 temperature trap. 0:Disable 1:Enable |
| 1.3.6.1.4.1.4756.20.270.20.1.98 | Columnf10GXFP3TemperaturAlarm | read-write | current | Local 10G-SXX card XFP3 temperature trap. 0:Disable 1:Enable |
| 1.3.6.1.4.1.4756.20.270.20.1.99 | Columnf10GTunableXFP2Wavelength | read-write | current | Set Tunable XFP2 Wavelength (ITU-T CH): The channel is restricted to 20 ~ 61 |
| 1.3.6.1.4.1.4756.20.270.20.1.100 | Columnf10GTunableXFP3Wavelength | read-write | current | Set Tunable XFP3 Wavelength (ITU-T CH): The channel is restricted to 20 ~ 61 |
| 1.3.6.1.4.1.4756.20.270.20.1.101 | Columnf10GLineRxPowerStatus | read-only | current | Local 10G-SXX card Line Rx Power Status: 0:Normal 1:Warning 2:Alarm |
| 1.3.6.1.4.1.4756.20.270.20.1.102 | Columnf10GLineRxPowerWarningThreshold | read-write | current | Set Line Rx Power Warning Threshold: Input range is from -40 to +10. |
| 1.3.6.1.4.1.4756.20.270.20.1.103 | Columnf10GLineRxPowerAlarmThreshold | read-write | current | Set Line Rx Power Alarm Threshold: Input range is from -40 to +10. |
| 1.3.6.1.4.1.4756.20.270.20.1.104 | Columnf10GLineRxPowerStatusAlarm | read-write | current | Local 10G-SXX card Line Rx Power Status trap. 0:Disable 1:Enable |
| 1.3.6.1.4.1.4756.20.270.20.1.105 | Columnf10GLineLosAssertAlarm | read-write | current | Local 10G-SXX card Line LOS Assert trap. 0:Disable 1:Enable |
| 1.3.6.1.4.1.4756.20.270.20.1.106 | Columnf10GPriRxPowerStatus | read-only | current | Local 10G-SXX card Primary Rx Power Status: 0:Normal 1:Warning 2:Alarm |
| 1.3.6.1.4.1.4756.20.270.20.1.107 | Columnf10GPriRxPowerWarningThreshold | read-write | current | Set Primary Rx Power Warning Threshold: Input range is from -40 to +10. |
| 1.3.6.1.4.1.4756.20.270.20.1.108 | Columnf10GPriRxPowerAlarmThreshold | read-write | current | Set Primary Rx Power Alarm Threshold: Input range is from -40 to +10. |
| 1.3.6.1.4.1.4756.20.270.20.1.109 | Columnf10GPriRxPowerStatusAlarm | read-write | current | Local 10G-SXX card Primary Rx Power Status trap. 0:Disable 1:Enable |
| 1.3.6.1.4.1.4756.20.270.20.1.110 | Columnf10GPriLosAssertAlarm | read-write | current | Local 10G-SXX card Primary LOS Assert trap. 0:Disable 1:Enable |
| 1.3.6.1.4.1.4756.20.270.20.1.111 | Columnf10GSecRxPowerStatus | read-only | current | Local 10G-SXX card Secondary Rx Power Status: 0:Normal 1:Warning 2:Alarm |
| 1.3.6.1.4.1.4756.20.270.20.1.112 | Columnf10GSecRxPowerWarningThreshold | read-write | current | Set Secondary Rx Power Warning Threshold: Input range is from -40 to +10. |
| 1.3.6.1.4.1.4756.20.270.20.1.113 | Columnf10GSecRxPowerAlarmThreshold | read-write | current | Set Secondary Rx Power Alarm Threshold: Input range is from -40 to +10. |
| 1.3.6.1.4.1.4756.20.270.20.1.114 | Columnf10GSecRxPowerStatusAlarm | read-write | current | Local 10G-SXX card Secondary Rx Power Status trap. 0:Disable 1:Enable |
| 1.3.6.1.4.1.4756.20.270.20.1.115 | Columnf10GSecLosAssertAlarm | read-write | current | Local 10G-SXX card Secondary LOS Assert trap. 0:Disable 1:Enable |
| 1.3.6.1.4.1.4756.20.270.20.1.116 | Columnf10GTunableXFP2 | read-only | current | Local 10G-SXX card Tunable XFP2. 0:No 1:Yes |
| 1.3.6.1.4.1.4756.20.270.20.1.117 | Columnf10GTunableXFP3 | read-only | current | Local 10G-SXX card Tunable XFP3. 0:No 1:Yes |
| 1.3.6.1.4.1.4756.20.280 | Nodef100I2ELocalCards | |||
| 1.3.6.1.4.1.4756.20.280.20 | Tablef100I2ELocalTable | not-accessible | current | A list of local FRM220-10/100I2E card entries. The number of entries is f100I2E-No-L. |
| 1.3.6.1.4.1.4756.20.280.20.1 | Rowf100I2ELocalEntry | not-accessible | current | An entry containing management information applicable to a particular local FRM220-10/100I2E card. |
| 1.3.6.1.4.1.4756.20.280.20.1.1 | Columnf100I2EChassisIndexLocal | read-only | current | A unique value for each local card. It is the chassis location number. |
| 1.3.6.1.4.1.4756.20.280.20.1.2 | Columnf100I2ESlotIndexLocal | read-only | current | A unique value for each local card. It is the slot location number. |
| 1.3.6.1.4.1.4756.20.280.20.1.3 | Columnf100I2ECardHWVerLocal | read-only | current | Local FRM220-10/100I-2E card hardware version x.xxx |
| 1.3.6.1.4.1.4756.20.280.20.1.4 | Columnf100I2ECardFWVerLocal | read-only | current | Local FRM220-10/100I-2E card firmware version x.xxx |
| 1.3.6.1.4.1.4756.20.280.20.1.5 | Columnf100I2ECardCPLDVerLocal | read-only | current | Local FRM220-10/100I-2E card CPLD version x.xxx |
| 1.3.6.1.4.1.4756.20.280.20.1.6 | Columnf100I2ECardFPGAVerLocal | read-only | current | Local FRM220-10/100I-2E card FPGA version x.xxx |
| 1.3.6.1.4.1.4756.20.280.20.1.7 | Columnf100I2EPortActiveLocal | read-write | current | Local FRM220-10/100I-2E card active: 0:Inactive 1:Active |
| 1.3.6.1.4.1.4756.20.280.20.1.8 | Columnf100I2EPortResetLocal | read-write | current | Force local FRM220-10/100I-2E card to reset mode: 0:Off 1:Action |
| 1.3.6.1.4.1.4756.20.280.20.1.9 | Columnf100I2ESettoDefaultLocal | read-write | current | Local FRM220-10/100I-2E card Set to default: 0:No action 1:Action |
| 1.3.6.1.4.1.4756.20.280.20.1.10 | Columnf100I2EFxLinkLocal | read-only | current | Local FRM220-10/100I-2E card fiber link status: 0:Down 1:Up |
| 1.3.6.1.4.1.4756.20.280.20.1.11 | Columnf100I2EFxFEFLocal | read-only | current | Local FRM220-10/100I-2E card fiber detected Far End Fault: 0:Off 1:Detected |
| 1.3.6.1.4.1.4756.20.280.20.1.12 | Columnf100I2EFxRemoPWRAbLocal | read-only | current | Local FRM220-10/100I-2E card fiber Remote Power status: 0:Abnormal 1:OK |
| 1.3.6.1.4.1.4756.20.280.20.1.13 | Columnf100I2EInBandManagLocal | read-write | current | Local FRM220-10/100I-2E card manages remote: 0:Disable 1:Enable |
| 1.3.6.1.4.1.4756.20.280.20.1.14 | Columnf100I2EUtp1LinkLocal | read-only | current | Local FRM220-10/100I-2E card UTP 1 link status: 0:Down 1:Up |
| 1.3.6.1.4.1.4756.20.280.20.1.15 | Columnf100I2EUtp1NegoLocal | read-write | current | Local FRM220-10/100I-2E card UTP 1 negotiation status: 0:Manual 1:Auto |
| 1.3.6.1.4.1.4756.20.280.20.1.16 | Columnf100I2EUtp1SpeedLocal | read-write | current | Local FRM220-10/100I-2E card UTP 1 speed: 0:10MHz 1:100MHz |
| 1.3.6.1.4.1.4756.20.280.20.1.17 | Columnf100I2EUtp1DuplexLocal | read-write | current | Local FRM220-10/100I-2E card UTP 1 duplex: 0:Half duplex mode 1:Full duplex mode |
| 1.3.6.1.4.1.4756.20.280.20.1.18 | Columnf100I2EUtp1SpeedStatusLocal | read-only | current | Local FRM220-10/100I-2E card UTP 1 speed status: 0:10MHz 1:100MHz |
| 1.3.6.1.4.1.4756.20.280.20.1.19 | Columnf100I2EUtp1DuplexStatusLocal | read-only | current | Local FRM220-10/100I-2E card UTP 1 duplex status: 0:Half duplex mode 1:Full duplex mode |
| 1.3.6.1.4.1.4756.20.280.20.1.20 | Columnf100I2EUtp1VIDNumberLocal | read-write | current | Local FRM220-10/100I-2E card UTP 1 VID number (1~4094) |
| 1.3.6.1.4.1.4756.20.280.20.1.21 | Columnf100I2EUtp2LinkLocal | read-only | current | Local FRM220-10/100I-2E card UTP 2 link status: 0:Down 1:Up |
| 1.3.6.1.4.1.4756.20.280.20.1.22 | Columnf100I2EUtp2NegoLocal | read-write | current | Local FRM220-10/100I-2E card UTP 2 negotiation status: 0:Manual 1:Auto |
| 1.3.6.1.4.1.4756.20.280.20.1.23 | Columnf100I2EUtp2SpeedLocal | read-write | current | Local FRM220-10/100I-2E card UTP 2 speed: 0:10MHz 1:100MHz |
| 1.3.6.1.4.1.4756.20.280.20.1.24 | Columnf100I2EUtp2DuplexLocal | read-write | current | Local FRM220-10/100I-2E card UTP 2 duplex: 0:Half duplex mode 1:Full duplex mode |
| 1.3.6.1.4.1.4756.20.280.20.1.25 | Columnf100I2EUtp2SpeedStatusLocal | read-only | current | Local FRM220-10/100I-2E card UTP 2 speed status: 0:10MHz 1:100MHz |
| 1.3.6.1.4.1.4756.20.280.20.1.26 | Columnf100I2EUtp2DuplexStatusLocal | read-only | current | Local FRM220-10/100I-2E card UTP 2 duplex status: 0:Half duplex mode 1:Full duplex mode |
| 1.3.6.1.4.1.4756.20.280.20.1.27 | Columnf100I2EUtp2VIDNumberLocal | read-write | current | Local FRM220-10/100I-2E card UTP 2 VID number (1~4094) |
| 1.3.6.1.4.1.4756.20.280.20.1.28 | Columnf100I2EIrl1ModeLocal | read-write | current | Local FRM220-10/100I-2E card UTP 1 Ingress Rate Limit mode: 0:No limit 1:n x 32K 2:n x 512K |
| 1.3.6.1.4.1.4756.20.280.20.1.29 | Columnf100I2EIrl1MultLocal | read-write | current | Local FRM220-10/100I-2E card UTP 1 Ingress Rate Limit multiple: When the irlMode-L is n x 32K mode, the irlMult-L should be the value between 0 to 255; When th… |
| 1.3.6.1.4.1.4756.20.280.20.1.30 | Columnf100I2EErl1ModeLocal | read-write | current | Local FRM220-10/100I-2E card UTP 1 Egress Rate Limit mode: 0:No limit 1:n x 32K 2:n x 512K |
| 1.3.6.1.4.1.4756.20.280.20.1.31 | Columnf100I2EErl1MultLocal | read-write | current | Local FRM220-10/100I-2E card UTP 1 Egress Rate Limit multiple: When the erlMode-L is n x 32K mode, the erlMult-L should be the value between 0 to 255; When the… |
| 1.3.6.1.4.1.4756.20.280.20.1.32 | Columnf100I2EIrl2ModeLocal | read-write | current | Local FRM220-10/100I-2E card UTP 2 Ingress Rate Limit mode: 0:No limit 1:n x 32K 2:n x 512K |
| 1.3.6.1.4.1.4756.20.280.20.1.33 | Columnf100I2EIrl2MultLocal | read-write | current | Local FRM220-10/100I-2E card UTP 2 Ingress Rate Limit multiple: When the irlMode-L is n x 32K mode, the irlMult-L should be the value between 0 to 255; When th… |
| 1.3.6.1.4.1.4756.20.280.20.1.34 | Columnf100I2EErl2ModeLocal | read-write | current | Local FRM220-10/100I-2E card UTP 2 Egress Rate Limit mode: 0:No limit 1:n x 32K 2:n x 512K |
| 1.3.6.1.4.1.4756.20.280.20.1.35 | Columnf100I2EErl2MultLocal | read-write | current | Local FRM220-10/100I-2E card UTP 2 Egress Rate Limit multiple: When the erlMode-L is n x 32K mode, the erlMult-L should be the value between 0 to 255; When the… |
| 1.3.6.1.4.1.4756.20.280.20.1.36 | Columnf100I2EOpModeLocal | read-write | current | Local FRM220-10/100I-2E card operation mode: 0:Switch mode 1:Tag based VLAN mode |
| 1.3.6.1.4.1.4756.20.280.20.1.37 | Columnf100I2ELfpModeLocal | read-write | current | Local FRM220-10/100I-2E card Link Fault Pass-through mode: 0:Disable 1:Enable |
| 1.3.6.1.4.1.4756.20.280.20.1.38 | Columnf100I2EAlsModeLocal | read-write | current | Local FRM220-10/100I-2E card Auto Laser Shutdown mode: 0:Disable 1:Enable |
| 1.3.6.1.4.1.4756.20.280.20.1.39 | Columnf100I2ESendFHRLocal | read-write | current | Local FRM220-10/100I-2E card send Fiber Hardware Reset to remote: 0:No action 1:Action |
| 1.3.6.1.4.1.4756.20.280.20.1.40 | Columnf100I2EFxDDLocal | read-only | current | Local FRM220-10/100I-2E card fiber Digital Diagnostic function: 0:No 1:Yes |
| 1.3.6.1.4.1.4756.20.280.20.1.41 | Columnf100I2EDDVendorLocal | read-only | current | Local FRM220-10/100I-2E card fiber D/D information: Vendor name |
| 1.3.6.1.4.1.4756.20.280.20.1.42 | Columnf100I2EDDPartNoLocal | read-only | current | Local FRM220-10/100I-2E card fiber D/D information: Vendor part number |
| 1.3.6.1.4.1.4756.20.280.20.1.43 | Columnf100I2EDDFiberTypeLocal | read-only | current | Local FRM220-10/100I-2E card fiber D/D information: Fiber Type |
| 1.3.6.1.4.1.4756.20.280.20.1.44 | Columnf100I2EDDWaveLenLocal | read-only | current | Local FRM220-10/100I-2E card fiber D/D information: Wave length |
| 1.3.6.1.4.1.4756.20.280.20.1.45 | Columnf100I2EDDWaveLen2Local | read-only | current | Local FRM220-10/100I-2E card fiber D/D information: Wave length 2 |
| 1.3.6.1.4.1.4756.20.280.20.1.46 | Columnf100I2EDDLinkLenLocal | read-only | current | Local FRM220-10/100I-2E card fiber D/D information: Link length |
| 1.3.6.1.4.1.4756.20.280.20.1.47 | Columnf100I2EDDLenUnitLocal | read-only | current | Local FRM220-10/100I-2E card fiber D/D information: Length Unit |
| 1.3.6.1.4.1.4756.20.280.20.1.48 | Columnf100I2EDDStatusLocal | read-only | current | Local FRM220-10/100I-2E card fiber D/D information: Status Support |
| 1.3.6.1.4.1.4756.20.280.20.1.49 | Columnf100I2EDDRxSensLocal | read-only | current | Local FRM220-10/100I-2E card fiber D/D information: Rx Sensitivity |
| 1.3.6.1.4.1.4756.20.280.20.1.50 | Columnf100I2EDDTxPWRLocal | read-only | current | Local FRM220-10/100I-2E card fiber D/D information: Tx power |
| 1.3.6.1.4.1.4756.20.280.20.1.51 | Columnf100I2EDDRxPWRLocal | read-only | current | Local FRM220-10/100I-2E card fiber D/D information: Rx power |
| 1.3.6.1.4.1.4756.20.280.20.1.52 | Columnf100I2EDDTempLocal | read-only | current | Local FRM220-10/100I-2E card fiber D/D information: Temperature in degree C |
| 1.3.6.1.4.1.4756.20.280.20.1.53 | Columnf100I2EDDPWRMarginLocal | read-only | current | Local FRM220-10/100I-2E card fiber D/D information: Power margin |
| 1.3.6.1.4.1.4756.20.280.20.1.54 | Columnf100I2EDDPWRLossLocal | read-only | current | Local FRM220-10/100I-2E card fiber D/D information: Power loss |
| 1.3.6.1.4.1.4756.20.281 | Nodef100I2ERemoteCards | |||
| 1.3.6.1.4.1.4756.20.281.20 | Tablef100I2ERemoteTable | not-accessible | current | A list of remote FRM220-10/100I-2E card entries. The number of entries is f100I2E-NoRemote. |
| 1.3.6.1.4.1.4756.20.281.20.1 | Rowf100I2ERemoteEntry | not-accessible | current | An entry containing management information applicable to a particular remote FRM220-10/100I-2E card. |
| 1.3.6.1.4.1.4756.20.281.20.1.1 | Columnf100I2EChassisIndexRemote | read-only | current | A unique value for each local card. It is the chassis location number. |
| 1.3.6.1.4.1.4756.20.281.20.1.2 | Columnf100I2ESlotIndexRemote | read-only | current | A unique value for each local card. It is the slot location number. |
| 1.3.6.1.4.1.4756.20.281.20.1.3 | Columnf100I2ECardHWVerRemote | read-only | current | Remote FRM220-10/100I-2E card hardware version x.xxx |
| 1.3.6.1.4.1.4756.20.281.20.1.4 | Columnf100I2ECardFWVerRemote | read-only | current | Remote FRM220-10/100I-2E card firmware version x.xxx |
| 1.3.6.1.4.1.4756.20.281.20.1.5 | Columnf100I2ECardCPLDVerRemote | read-only | current | Remote FRM220-10/100I-2E card CPLD version x.xxx |
| 1.3.6.1.4.1.4756.20.281.20.1.6 | Columnf100I2ECardFPGAVerRemote | read-only | current | Remote FRM220-10/100I-2E card FPGA version x.xxx |
| 1.3.6.1.4.1.4756.20.281.20.1.7 | Columnf100I2EPortActiveRemote | read-only | current | Remote FRM220-10/100I-2E card active: 0:Inactive 1:Active |
| 1.3.6.1.4.1.4756.20.281.20.1.8 | Columnf100I2EPortResetRemote | read-write | current | Force local FRM220-10/100I-2E card to reset mode: 0:Off 1:Action |
| 1.3.6.1.4.1.4756.20.281.20.1.9 | Columnf100I2ESettoDefaultRemote | read-write | current | Remote FRM220-10/100I-2E card Set to default: 0:No action 1:Action |
| 1.3.6.1.4.1.4756.20.281.20.1.10 | Columnf100I2EFxLinkRemote | read-only | current | Remote FRM220-10/100I-2E card fiber link status: 0:Down 1:Up |
| 1.3.6.1.4.1.4756.20.281.20.1.11 | Columnf100I2EFxFEFRemote | read-only | current | Remote FRM220-10/100I-2E card fiber detected Far End Fault: 0:Off 1:Detected |
| 1.3.6.1.4.1.4756.20.281.20.1.12 | Columnf100I2EFxRemoPWRAbRemote | read-only | current | Remote FRM220-10/100I-2E card fiber Remote Power status: 0:Abnormal 1:OK |
| 1.3.6.1.4.1.4756.20.281.20.1.13 | Columnf100I2EUtp1LinkRemote | read-only | current | Remote FRM220-10/100I-2E card UTP 1 link status: 0:Down 1:Up |
| 1.3.6.1.4.1.4756.20.281.20.1.14 | Columnf100I2EUtp1NegoRemote | read-write | current | Remote FRM220-10/100I-2E card UTP 1 negotiation status: 0:Manual 1:Auto |
| 1.3.6.1.4.1.4756.20.281.20.1.15 | Columnf100I2EUtp1SpeedRemote | read-write | current | Remote FRM220-10/100I-2E card UTP 1 speed: 0:10MHz 1:100MHz |
| 1.3.6.1.4.1.4756.20.281.20.1.16 | Columnf100I2EUtp1DuplexRemote | read-write | current | Remote FRM220-10/100I-2E card UTP 1 duplex: 0:Half duplex mode 1:Full duplex mode |
| 1.3.6.1.4.1.4756.20.281.20.1.17 | Columnf100I2EUtp1SpeedStatusRemote | read-only | current | Remote FRM220-10/100I-2E card UTP 1 speed status: 0:10MHz 1:100MHz |
| 1.3.6.1.4.1.4756.20.281.20.1.18 | Columnf100I2EUtp1DuplexStatusRemote | read-only | current | Remote FRM220-10/100I-2E card UTP 1 duplex status: 0:Half duplex mode 1:Full duplex mode |
| 1.3.6.1.4.1.4756.20.281.20.1.19 | Columnf100I2EUtp1VIDNumberRemote | read-write | current | Remote FRM220-10/100I-2E card UTP 1 VID number (1~4094) |
| 1.3.6.1.4.1.4756.20.281.20.1.20 | Columnf100I2EUtp2LinkRemote | read-only | current | Remote FRM220-10/100I-2E card UTP 2 link status: 0:Down 1:Up |
| 1.3.6.1.4.1.4756.20.281.20.1.21 | Columnf100I2EUtp2NegoRemote | read-write | current | Remote FRM220-10/100I-2E card UTP 2 negotiation status: 0:Manual 1:Auto |
| 1.3.6.1.4.1.4756.20.281.20.1.22 | Columnf100I2EUtp2SpeedRemote | read-write | current | Remote FRM220-10/100I-2E card UTP 2 speed: 0:10MHz 1:100MHz |
| 1.3.6.1.4.1.4756.20.281.20.1.23 | Columnf100I2EUtp2DuplexRemote | read-write | current | Remote FRM220-10/100I-2E card UTP 2 duplex: 0:Half duplex mode 1:Full duplex mode |
| 1.3.6.1.4.1.4756.20.281.20.1.24 | Columnf100I2EUtp2SpeedStatusRemote | read-only | current | Remote FRM220-10/100I-2E card UTP 2 speed status: 0:10MHz 1:100MHz |
| 1.3.6.1.4.1.4756.20.281.20.1.25 | Columnf100I2EUtp2DuplexStatusRemote | read-only | current | Remote FRM220-10/100I-2E card UTP 2 duplex status: 0:Half duplex mode 1:Full duplex mode |
| 1.3.6.1.4.1.4756.20.281.20.1.26 | Columnf100I2EUtp2VIDNumberRemote | read-write | current | Remote FRM220-10/100I-2E card UTP 2 VID number (1~4094) |
| 1.3.6.1.4.1.4756.20.281.20.1.27 | Columnf100I2EIrl1ModeRemote | read-write | current | Remote FRM220-10/100I-2E card UTP 1 Ingress Rate Limit mode: 0:No limit 1:n x 32K 2:n x 512K |
| 1.3.6.1.4.1.4756.20.281.20.1.28 | Columnf100I2EIrl1MultRemote | read-write | current | Remote FRM220-10/100I-2E card UTP 1 Ingress Rate Limit multiple: When the irlMode-L is n x 32K mode, the irlMult-L should be the value between 0 to 255; When t… |
| 1.3.6.1.4.1.4756.20.281.20.1.29 | Columnf100I2EErl1ModeRemote | read-write | current | Remote FRM220-10/100I-2E card UTP 1 Egress Rate Limit mode: 0:No limit 1:n x 32K 2:n x 512K |
| 1.3.6.1.4.1.4756.20.281.20.1.30 | Columnf100I2EErl1MultRemote | read-write | current | Remote FRM220-10/100I-2E card UTP 1 Egress Rate Limit multiple: When the erlMode-L is n x 32K mode, the erlMult-L should be the value between 0 to 255; When th… |
| 1.3.6.1.4.1.4756.20.281.20.1.31 | Columnf100I2EIrl2ModeRemote | read-write | current | Remote FRM220-10/100I-2E card UTP 2 Ingress Rate Limit mode: 0:No limit 1:n x 32K 2:n x 512K |
| 1.3.6.1.4.1.4756.20.281.20.1.32 | Columnf100I2EIrl2MultRemote | read-write | current | Remote FRM220-10/100I-2E card UTP 2 Ingress Rate Limit multiple: When the irlMode-L is n x 32K mode, the irlMult-L should be the value between 0 to 255; When t… |
| 1.3.6.1.4.1.4756.20.281.20.1.33 | Columnf100I2EErl2ModeRemote | read-write | current | Remote FRM220-10/100I-2E card UTP 2 Egress Rate Limit mode: 0:No limit 1:n x 32K 2:n x 512K |
| 1.3.6.1.4.1.4756.20.281.20.1.34 | Columnf100I2EErl2MultRemote | read-write | current | Remote FRM220-10/100I-2E card UTP 2 Egress Rate Limit multiple: When the erlMode-L is n x 32K mode, the erlMult-L should be the value between 0 to 255; When th… |
| 1.3.6.1.4.1.4756.20.281.20.1.35 | Columnf100I2EOpModeRemote | read-write | current | Remote FRM220-10/100I-2E card operation mode: 0:Switch mode 1:Tag based VLAN mode |
| 1.3.6.1.4.1.4756.20.281.20.1.36 | Columnf100I2ELfpModeRemote | read-write | current | Remote FRM220-10/100I-2E card Link Fault Pass-through mode: 0:Disable 1:Enable |
| 1.3.6.1.4.1.4756.20.281.20.1.37 | Columnf100I2EAlsModeRemote | read-write | current | Remote FRM220-10/100I-2E card Auto Laser Shutdown mode: 0:Disable 1:Enable |
| 1.3.6.1.4.1.4756.20.281.20.1.38 | Columnf100I2EFhrModeRemote | read-write | current | Remote 10/100I-2E card accepts Fiber Hardware Reset mode: 0:Disable 1:Enable |
| 1.3.6.1.4.1.4756.20.281.20.1.39 | Columnf100I2EFxDDRemote | read-only | current | Remote FRM220-10/100I-2E card fiber Digital Diagnostic function: 0:No 1:Yes |
| 1.3.6.1.4.1.4756.20.281.20.1.40 | Columnf100I2EDDVendorRemote | read-only | current | Remote FRM220-10/100I-2E card fiber D/D information: Vendor name |
| 1.3.6.1.4.1.4756.20.281.20.1.41 | Columnf100I2EDDPartNoRemote | read-only | current | Remote FRM220-10/100I-2E card fiber D/D information: Vendor part number |
| 1.3.6.1.4.1.4756.20.281.20.1.42 | Columnf100I2EDDFiberTypeRemote | read-only | current | Remote FRM220-10/100I-2E card fiber D/D information: Fiber Type |
| 1.3.6.1.4.1.4756.20.281.20.1.43 | Columnf100I2EDDWaveLenRemote | read-only | current | Remote FRM220-10/100I-2E card fiber D/D information: Wave length |
| 1.3.6.1.4.1.4756.20.281.20.1.44 | Columnf100I2EDDWaveLen2Remote | read-only | current | Remote FRM220-10/100I-2E card fiber D/D information: Wave length 2 |
| 1.3.6.1.4.1.4756.20.281.20.1.45 | Columnf100I2EDDLinkLenRemote | read-only | current | Remote FRM220-10/100I-2E card fiber D/D information: Link length |
| 1.3.6.1.4.1.4756.20.281.20.1.46 | Columnf100I2EDDLenUnitRemote | read-only | current | Remote FRM220-10/100I-2E card fiber D/D information: Length Unit |
| 1.3.6.1.4.1.4756.20.281.20.1.47 | Columnf100I2EDDStatusRemote | read-only | current | Remote FRM220-10/100I-2E card fiber D/D information: Status Support |
| 1.3.6.1.4.1.4756.20.281.20.1.48 | Columnf100I2EDDRxSensRemote | read-only | current | Remote FRM220-10/100I-2E card fiber D/D information: Rx Sensitivity |
| 1.3.6.1.4.1.4756.20.281.20.1.49 | Columnf100I2EDDTxPWRRemote | read-only | current | Remote FRM220-10/100I-2E card fiber D/D information: Tx power |
| 1.3.6.1.4.1.4756.20.281.20.1.50 | Columnf100I2EDDRxPWRRemote | read-only | current | Remote FRM220-10/100I-2E card fiber D/D information: Rx power |
| 1.3.6.1.4.1.4756.20.281.20.1.51 | Columnf100I2EDDTempRemote | read-only | current | Remote FRM220-10/100I-2E card fiber D/D information: Temperature in degree C |
| 1.3.6.1.4.1.4756.20.281.20.1.52 | Columnf100I2EDDPWRMarginRemote | read-only | current | Remote FRM220-10/100I-2E card fiber D/D information: Power margin |
| 1.3.6.1.4.1.4756.20.281.20.1.53 | Columnf100I2EDDPWRLossRemote | read-only | current | Remote FRM220-10/100I-2E card fiber D/D information: Power loss |
| 1.3.6.1.4.1.4756.20.290 | NodefswCards | |||
| 1.3.6.1.4.1.4756.20.290.20 | TablefswTable | not-accessible | current | A list of local FRM220-FSW103 card entries. The number of entries is fsw-No-L. |
| 1.3.6.1.4.1.4756.20.290.20.1 | RowfswEntry | not-accessible | current | An entry containing management information applicable to a particular local FRM220-FSW103 card. |
| 1.3.6.1.4.1.4756.20.290.20.1.1 | ColumnfswChassisIndex | read-only | current | A unique value for each local card. It is the chassis location number. |
| 1.3.6.1.4.1.4756.20.290.20.1.2 | ColumnfswSlotIndex | read-only | current | A unique value for each local card. It is the slot location number. |
| 1.3.6.1.4.1.4756.20.290.20.1.3 | ColumnfswCardHWVer | read-only | current | Local FRM220-FSW103 card hardware version x.xxx |
| 1.3.6.1.4.1.4756.20.290.20.1.4 | ColumnfswCardFWVer | read-only | current | Local FRM220-FSW103 card firmware version x.xxx |
| 1.3.6.1.4.1.4756.20.290.20.1.5 | ColumnfswCardCPLDVer | read-only | current | Local FRM220-FSW103 card CPLD version x.xxx |
| 1.3.6.1.4.1.4756.20.290.20.1.6 | ColumnfswCardFPGAVer | read-only | current | Local FRM220-FSW103 card FPGA version x.xxx |
| 1.3.6.1.4.1.4756.20.290.20.1.7 | ColumnfswDeviceActive | read-write | current | Local FRM220-FSW103 card active: 0:Disable 1:Enable |
| 1.3.6.1.4.1.4756.20.290.20.1.8 | ColumnfswFxLink | read-only | current | Local FRM220-FSW103 card fiber link status: 0:Down 1:Up |
| 1.3.6.1.4.1.4756.20.290.20.1.9 | ColumnfswFxLoss | read-only | current | Local FRM220-FSW103 card fiber loss status: 0:No 1:Yes |
| 1.3.6.1.4.1.4756.20.290.20.1.10 | ColumnfswPortReset | read-write | current | Force local FRM220-FSW103 card to reset mode: 0:Off 1:Action |
| 1.3.6.1.4.1.4756.20.290.20.1.11 | ColumnfswSettoDefault | read-write | current | Force local FRM220-FSW103 card set to default: 0:Off 1:Action |
| 1.3.6.1.4.1.4756.20.290.20.1.12 | ColumnfswAlsMode | read-write | current | Local FRM220-FSW103 card Auto Laser Shutdown mode: 0:Disable 1:Enable |
| 1.3.6.1.4.1.4756.20.290.20.1.13 | ColumnfswUtp1Link | read-only | current | Local FRM220-FSW103 card UTP 1 link status: 0:Down 1:Up |
| 1.3.6.1.4.1.4756.20.290.20.1.14 | ColumnfswUtp1Active | read-write | current | Local FRM220-FSW103 card UTP 1 port active: 0:Disable 1:Enable |
| 1.3.6.1.4.1.4756.20.290.20.1.15 | ColumnfswUtp1Nego | read-write | current | Local FRM220-FSW103 card UTP 1 negotiation: 0:Manual 1:Auto |
| 1.3.6.1.4.1.4756.20.290.20.1.16 | ColumnfswUtp1Speed | read-write | current | Local FRM220-FSW103 card UTP 1 speed: 0:10M 1:100M |
| 1.3.6.1.4.1.4756.20.290.20.1.17 | ColumnfswUtp1Duplex | read-write | current | Local FRM220-FSW103 card UTP 1 duplex: 0:Half duplex mode 1:Full duplex mode |
| 1.3.6.1.4.1.4756.20.290.20.1.18 | ColumnfswUtp1SpeedSTS | read-only | current | Local FRM220-FSW103 card UTP 1 speed status: 0:10M 1:100M |
| 1.3.6.1.4.1.4756.20.290.20.1.19 | ColumnfswUtp1DuplexSTS | read-only | current | Local FRM220-FSW103 card UTP 1 duplex status: 0:Half duplex mode 1:Full duplex mode |
| 1.3.6.1.4.1.4756.20.290.20.1.20 | ColumnfswUtp2Link | read-only | current | Local FRM220-FSW103 card UTP 2 link status: 0:Down 1:Up |
| 1.3.6.1.4.1.4756.20.290.20.1.21 | ColumnfswUtp2Active | read-write | current | Local FRM220-FSW103 card UTP 2 port active: 0:Disable 1:Enable |
| 1.3.6.1.4.1.4756.20.290.20.1.22 | ColumnfswUtp2Nego | read-write | current | Local FRM220-FSW103 card UTP 2 negotiation: 0:Manual 1:Auto |
| 1.3.6.1.4.1.4756.20.290.20.1.23 | ColumnfswUtp2Speed | read-write | current | Local FRM220-FSW103 card UTP 2 speed: 0:10M 1:100M |
| 1.3.6.1.4.1.4756.20.290.20.1.24 | ColumnfswUtp2Duplex | read-write | current | Local FRM220-FSW103 card UTP 2 duplex: 0:Half duplex mode 1:Full duplex mode |
| 1.3.6.1.4.1.4756.20.290.20.1.25 | ColumnfswUtp2SpeedSTS | read-only | current | Local FRM220-FSW103 card UTP 2 speed status: 0:10M 1:100M |
| 1.3.6.1.4.1.4756.20.290.20.1.26 | ColumnfswUtp2DuplexSTS | read-only | current | Local FRM220-FSW103 card UTP 2 duplex status: 0:Half duplex mode 1:Full duplex mode |
| 1.3.6.1.4.1.4756.20.290.20.1.27 | ColumnfswUtp3Link | read-only | current | Local FRM220-FSW103 card UTP 3 link status: 0:Down 1:Up |
| 1.3.6.1.4.1.4756.20.290.20.1.28 | ColumnfswUtp3Active | read-write | current | Local FRM220-FSW103 card UTP 3 port active: 0:Disable 1:Enable |
| 1.3.6.1.4.1.4756.20.290.20.1.29 | ColumnfswUtp3Nego | read-write | current | Local FRM220-FSW103 card UTP 3 negotiation: 0:Manual 1:Auto |
| 1.3.6.1.4.1.4756.20.290.20.1.30 | ColumnfswUtp3Speed | read-write | current | Local FRM220-FSW103 card UTP 3 speed: 0:10M 1:100M |
| 1.3.6.1.4.1.4756.20.290.20.1.31 | ColumnfswUtp3Duplex | read-write | current | Local FRM220-FSW103 card UTP 3 duplex: 0:Half duplex mode 1:Full duplex mode |
| 1.3.6.1.4.1.4756.20.290.20.1.32 | ColumnfswUtp3SpeedSTS | read-only | current | Local FRM220-FSW103 card UTP 3 speed status: 0:10M 1:100M |
| 1.3.6.1.4.1.4756.20.290.20.1.33 | ColumnfswUtp3DuplexSTS | read-only | current | Local FRM220-FSW103 card UTP 3 duplex status: 0:Half duplex mode 1:Full duplex mode |
| 1.3.6.1.4.1.4756.20.290.20.1.34 | ColumnfswFxDD | read-only | current | Local FRM220-FSW103 card fiber Digital Diagnostic function: 0:No 1:Yes |
| 1.3.6.1.4.1.4756.20.290.20.1.35 | ColumnfswDDVendor | read-only | current | Local FRM220-FSW103 card fiber D/D information: Vendor name |
| 1.3.6.1.4.1.4756.20.290.20.1.36 | ColumnfswDDPartNo | read-only | current | Local FRM220-FSW103 card fiber D/D information: Vendor part number |
| 1.3.6.1.4.1.4756.20.290.20.1.37 | ColumnfswDDFiberType | read-only | current | Local FRM220-FSW103 card fiber D/D information: Fiber Type |
| 1.3.6.1.4.1.4756.20.290.20.1.38 | ColumnfswDDWaveLen | read-only | current | Local FRM220-FSW103 card fiber D/D information: Wave length |
| 1.3.6.1.4.1.4756.20.290.20.1.39 | ColumnfswDDWaveLen2 | read-only | current | Local FRM220-FSW103 card fiber D/D information: Wave length 2 |
| 1.3.6.1.4.1.4756.20.290.20.1.40 | ColumnfswDDLinkLen | read-only | current | Local FRM220-FSW103 card fiber D/D information: Link length |
| 1.3.6.1.4.1.4756.20.290.20.1.41 | ColumnfswDDLenUnit | read-only | current | Local FRM220-FSW103 card fiber D/D information: Length Unit |
| 1.3.6.1.4.1.4756.20.290.20.1.42 | ColumnfswDDStatus | read-only | current | Local FRM220-FSW103 card fiber D/D information: Status Support |
| 1.3.6.1.4.1.4756.20.290.20.1.43 | ColumnfswDDRxSens | read-only | current | Local FRM220-FSW103 card fiber D/D information: Rx Sensitivity |
| 1.3.6.1.4.1.4756.20.290.20.1.44 | ColumnfswDDTxPWR | read-only | current | Local FRM220-FSW103 card fiber D/D information: Tx power |
| 1.3.6.1.4.1.4756.20.290.20.1.45 | ColumnfswDDRxPWR | read-only | current | Local FRM220-FSW103 card fiber D/D information: Rx power |
| 1.3.6.1.4.1.4756.20.290.20.1.46 | ColumnfswDDTemp | read-only | current | Local FRM220-FSW103 card fiber D/D information: Temperature in degree C |
| 1.3.6.1.4.1.4756.20.290.20.1.47 | ColumnfswDDPWRMargin | read-only | current | Local FRM220-FSW103 card fiber D/D information: Power margin |
| 1.3.6.1.4.1.4756.20.300 | Nodef1000EASXLocalCards | |||
| 1.3.6.1.4.1.4756.20.300.40 | Tablef1000EASXLocalTable | not-accessible | current | A list of local 1000EAS/X card entries. |
| 1.3.6.1.4.1.4756.20.300.40.1 | Rowf1000EASXLocalEntry | not-accessible | current | An entry containing management information applicable to a particular local f1000EASX card. |
| 1.3.6.1.4.1.4756.20.300.40.1.1 | Columnf1000EASXChassisIndexLocal | read-only | current | A unique value for each chassis ID. For CH20, it is the chassis ID. For CH08, it is always 0. |
| 1.3.6.1.4.1.4756.20.300.40.1.2 | Columnf1000EASXSlotIndexLocal | read-only | current | A unique value for each local card. It is the slot location number. |
| 1.3.6.1.4.1.4756.20.300.40.1.3 | Columnf1000EASXCardHWVerLocal | read-only | current | Local device card hardware version x.xxx |
| 1.3.6.1.4.1.4756.20.300.40.1.4 | Columnf1000EASXCardFWVerLocal | read-only | current | Local device card firmware version x.xxx |
| 1.3.6.1.4.1.4756.20.300.40.1.5 | Columnf1000EASXCardCPLDVerLocal | read-only | current | Local device card CPLD version x.xxx |
| 1.3.6.1.4.1.4756.20.300.40.1.6 | Columnf1000EASXCardFPGAVerLocal | read-only | current | Local device card FPGA version x.xxx |
| 1.3.6.1.4.1.4756.20.300.40.1.7 | Columnf1000EASXModelLocal | read-only | current | Local 1000EAS/X Serial Type |
| 1.3.6.1.4.1.4756.20.300.40.1.8 | Columnf1000EASXFiber1LinkLocal | read-only | current | Local device card fiber port 1 link status: 0:Down 1:Up |
| 1.3.6.1.4.1.4756.20.300.40.1.9 | Columnf1000EASXFiber1OAMLoopedLocal | read-only | current | Local device card fiber port 1 OAM looped: 0:Off 1:on |
| 1.3.6.1.4.1.4756.20.300.40.1.10 | Columnf1000EASXFiber1LBTestLocal | read-write | current | Force remote device card to do fiber port 1 LoopBack testing: 0:Off 1:Action |
| 1.3.6.1.4.1.4756.20.300.40.1.11 | Columnf1000EASXFiber1OAMRLBStatusLocal | read-only | current | Remote device card fiber port 1 LoopBack testing status: 0:Off 1:Ok 2:Fail |
| 1.3.6.1.4.1.4756.20.300.40.1.12 | Columnf1000EASXFiber1RemoPwrAbLocal | read-only | current | Local device card fiber port 1 Remote Power status: 0:Abnormal 1:OK 2:None |
| 1.3.6.1.4.1.4756.20.300.40.1.13 | Columnf1000EASXFiber1IngressRateLocal | read-write | current | Local device card fiber 1 Ingress Rate Limit: 0 = Unlimit input format: 64k(K),100m(M),100 If doesn't input the unit, the default was Mega. Limite Rate : 64K ~… |
| 1.3.6.1.4.1.4756.20.300.40.1.14 | Columnf1000EASXFiber1EgressRateLocal | read-write | current | Local device card fiber 1 Egress Rate Limit: 0 = Unlimit input format: 64k(K),100m(M),100 If doesn't input the unit, the default was Mega. Limite Rate : 64K ~ … |
| 1.3.6.1.4.1.4756.20.300.40.1.15 | Columnf1000EASXFiber2LinkLocal | read-only | current | Local device card fiber port 2 link status: 0:Down 1:Up |
| 1.3.6.1.4.1.4756.20.300.40.1.16 | Columnf1000EASXFiber2OAMLoopedLocal | read-only | current | Local device card fiber port 2 OAM looped: 0:Off 1:on |
| 1.3.6.1.4.1.4756.20.300.40.1.17 | Columnf1000EASXFiber2LBTestLocal | read-write | current | Force remote device card to do fiber port 2 LoopBack testing: 0:Off 1:Action |
| 1.3.6.1.4.1.4756.20.300.40.1.18 | Columnf1000EASXFiber2OAMRLBStatusLocal | read-only | current | Remote device card fiber port 1 LoopBack testing status: 0:Off 1:Ok 2:Fail |
| 1.3.6.1.4.1.4756.20.300.40.1.19 | Columnf1000EASXFiber2RemoPwrAbLocal | read-only | current | Local device card fiber port 2 Remote Power status: 0:Abnormal 1:OK 2:None |
| 1.3.6.1.4.1.4756.20.300.40.1.20 | Columnf1000EASXFiber2IngressRateLocal | read-write | current | Local device card fiber 2 Ingress Rate Limit: 0 = Unlimit input format: 64k(K),100m(M),100 If doesn't input the unit, the default was Mega. Limite Rate : 64K ~… |
| 1.3.6.1.4.1.4756.20.300.40.1.21 | Columnf1000EASXFiber2EgressRateLocal | read-write | current | Local device card fiber 2 Egress Rate Limit: 0 = Unlimit input format: 64k(K),100m(M),100 If doesn't input the unit, the default was Mega. Limite Rate : 64K ~ … |
| 1.3.6.1.4.1.4756.20.300.40.1.22 | Columnf1000EASXUtp3LinkLocal | read-only | current | Local device card UTP port 3 link status: 0:Down 1:Up |
| 1.3.6.1.4.1.4756.20.300.40.1.23 | Columnf1000EASXUtp3NegoLocal | read-write | current | Local device card UTP port 3 negotiation status: 0:Manual 1:Auto |
| 1.3.6.1.4.1.4756.20.300.40.1.24 | Columnf1000EASXUtp3SpeedLocal | read-write | current | Local device card UTP port 3 speed setting: 0:10 Base-T 1:100 Base-TX 2:1000 Base-TX |
| 1.3.6.1.4.1.4756.20.300.40.1.25 | Columnf1000EASXUtp3DuplexLocal | read-write | current | Local device card UTP port 3 duplex setting: 0:Half duplex mode 1:Full duplex mode |
| 1.3.6.1.4.1.4756.20.300.40.1.26 | Columnf1000EASXUtp3SpeedStatusLocal | read-only | current | Local device card UTP port 3 speed status: 0:10 Base-T 1:100 Base-TX 2:1000 Base-TX |
| 1.3.6.1.4.1.4756.20.300.40.1.27 | Columnf1000EASXUtp3DuplexStatusLocal | read-only | current | Local device card UTP port 3 duplex status: 0:Half duplex mode 1:Full duplex mode |
| 1.3.6.1.4.1.4756.20.300.40.1.28 | Columnf1000EASXUtp3IngressRateLocal | read-write | current | Local device card utp 3 Ingress Rate Limit: 0 = Unlimit input format: 64k(K),100m(M),100 If doesn't input the unit, the default was Mega. Limite Rate : 64K ~ 9… |
| 1.3.6.1.4.1.4756.20.300.40.1.29 | Columnf1000EASXUtp3EgressRateLocal | read-write | current | Local device card utp 3 Egress Rate Limit: 0 = Unlimit input format: 64k(K),100m(M),100 If doesn't input the unit, the default was Mega. Limite Rate : 64K ~ 99… |
| 1.3.6.1.4.1.4756.20.300.40.1.30 | Columnf1000EASXUtp4LinkLocal | read-only | current | Local device card UTP port 4 link status: 0:Down 1:Up |
| 1.3.6.1.4.1.4756.20.300.40.1.31 | Columnf1000EASXUtp4NegoLocal | read-write | current | Local device card UTP port 4 negotiation status: 0:Manual 1:Auto |
| 1.3.6.1.4.1.4756.20.300.40.1.32 | Columnf1000EASXUtp4SpeedLocal | read-write | current | Local device card UTP port 4 speed setting: 0:10 Base-T 1:100 Base-TX 2:1000 Base-TX |
| 1.3.6.1.4.1.4756.20.300.40.1.33 | Columnf1000EASXUtp4DuplexLocal | read-write | current | Local device card UTP port 4 duplex setting: 0:Half duplex mode 1:Full duplex mode |
| 1.3.6.1.4.1.4756.20.300.40.1.34 | Columnf1000EASXUtp4SpeedStatusLocal | read-only | current | Local device card UTP port 4 speed status: 0:10 Base-T 1:100 Base-TX 2:1000 Base-TX |
| 1.3.6.1.4.1.4756.20.300.40.1.35 | Columnf1000EASXUtp4DuplexStatusLocal | read-only | current | Local device card UTP port 4 duplex status: 0:Half duplex mode 1:Full duplex mode |
| 1.3.6.1.4.1.4756.20.300.40.1.36 | Columnf1000EASXUtp4IngressRateLocal | read-write | current | Local device card utp 4 Ingress Rate Limit: 0 = Unlimit input format: 64k(K),100m(M),100 If doesn't input the unit, the default was Mega. Limite Rate : 64K ~ 9… |
| 1.3.6.1.4.1.4756.20.300.40.1.37 | Columnf1000EASXUtp4EgressRateLocal | read-write | current | Local device card utp 4 Egress Rate Limit: 0 = Unlimit input format: 64k(K),100m(M),100 If doesn't input the unit, the default was Mega. Limite Rate : 64K ~ 99… |
| 1.3.6.1.4.1.4756.20.300.40.1.38 | Columnf1000EASXDeviceActiveLocal | read-write | current | Local device card active mode: (It is read-only in local device.) 0:Disable 1:Enable |
| 1.3.6.1.4.1.4756.20.300.40.1.39 | Columnf1000EASXDeviceResetLocal | read-write | current | Force local device card to reset mode: 0:Off 1:Action |
| 1.3.6.1.4.1.4756.20.300.40.1.40 | Columnf1000EASXFiber1ActiveLocal | read-write | current | Local device fiber port 1 active mode: 0:Disable 1:Enable |
| 1.3.6.1.4.1.4756.20.300.40.1.41 | Columnf1000EASXFiber2ActiveLocal | read-write | current | Local device fiber port 2 active mode: 0:Disable 1:Enable |
| 1.3.6.1.4.1.4756.20.300.40.1.42 | Columnf1000EASXUtp3ActiveLocal | read-write | current | Local device UTP port 3 active mode: 0:Disable 1:Enable |
| 1.3.6.1.4.1.4756.20.300.40.1.43 | Columnf1000EASXUtp4ActiveLocal | read-write | current | Local device UTP port 4 active mode: 0:Disable 1:Enable |
| 1.3.6.1.4.1.4756.20.300.40.1.44 | Columnf1000EASXOamChAModeLocal | read-write | current | Local device OAM Channel A mode: 0:Disable 1:passive 2:Active |
| 1.3.6.1.4.1.4756.20.300.40.1.45 | Columnf1000EASXOamChBModeLocal | read-write | current | Local device OAM Channel B mode: 0:Disable 1:passive 2:Active |
| 1.3.6.1.4.1.4756.20.300.40.1.46 | Columnf1000EASXOamMaxPDUsLocal | read-write | current | Local device OAM max OAMPDU size: 60-1518 Octets |
| 1.3.6.1.4.1.4756.20.300.40.1.47 | Columnf1000EASXFiber1AlsLocal | read-write | current | Local device card port 1 Auto Laser Shutdown mode: 0:Disable 1:Enable |
| 1.3.6.1.4.1.4756.20.300.40.1.48 | Columnf1000EASXFiber2AlsLocal | read-write | current | Local device card port 2 Auto Laser Shutdown mode: 0:Disable 1:Enable |
| 1.3.6.1.4.1.4756.20.300.40.1.49 | Columnf1000EASXPauseFrameLocal | read-write | current | Local device card pause frame mode: 0:Disable 1:Enable |
| 1.3.6.1.4.1.4756.20.300.40.1.50 | Columnf1000EASXSendFHRtoALocal | read-write | current | Local device card port 1 send Fiber Hardware Reset to remote: 0:No action 1:Action |
| 1.3.6.1.4.1.4756.20.300.40.1.51 | Columnf1000EASXSendFHRtoBLocal | read-write | current | Local device card port 2 send Fiber Hardware Reset to remote: 0:No action 1:Action |
| 1.3.6.1.4.1.4756.20.300.40.1.52 | Columnf1000EASXFiber1LLFDepLogiLocal | read-write | current | Local device card port 1 Link Loss Forwarding depends boolean logic: 0:and 1:or |
| 1.3.6.1.4.1.4756.20.300.40.1.53 | Columnf1000EASXFiber1LLFDepPort2Local | read-write | current | Local device card port 1 Link Loss Forwarding depends on port 2 Fiber Rx link: 0:don't care 1:selected |
| 1.3.6.1.4.1.4756.20.300.40.1.54 | Columnf1000EASXFiber1LLFDepPort3Local | read-write | current | Local device card port 1 Link Loss Forwarding depends on port 3 Ethernet Rx link: 0:don't care 1:selected |
| 1.3.6.1.4.1.4756.20.300.40.1.55 | Columnf1000EASXFiber1LLFDepPort4Local | read-write | current | Local device card port 1 Link Loss Forwarding depends on port 4 Ethernet Rx link: 0:don't care 1:selected |
| 1.3.6.1.4.1.4756.20.300.40.1.56 | Columnf1000EASXFiber2LLFDepLogiLocal | read-write | current | Local device card port 2 Link Loss Forwarding depends boolean logic: 0:and 1:or |
| 1.3.6.1.4.1.4756.20.300.40.1.57 | Columnf1000EASXFiber2LLFDepPort1Local | read-write | current | Local device card port 2 Link Loss Forwarding depends on port 1 Fiber Rx link: 0:don't care 1:selected |
| 1.3.6.1.4.1.4756.20.300.40.1.58 | Columnf1000EASXFiber2LLFDepPort3Local | read-write | current | Local device card port 2 Link Loss Forwarding depends on port 3 Ethernet Rx link: 0:don't care 1:selected |
| 1.3.6.1.4.1.4756.20.300.40.1.59 | Columnf1000EASXFiber2LLFDepPort4Local | read-write | current | Local device card port 2 Link Loss Forwarding depends on port 4 Ethernet Rx link: 0:don't care 1:selected |
| 1.3.6.1.4.1.4756.20.300.40.1.60 | Columnf1000EASXUtp3LLFDepLogiLocal | read-write | current | Local device card port 3 Link Loss Forwarding depends boolean logic: 0:and 1:or |
| 1.3.6.1.4.1.4756.20.300.40.1.61 | Columnf1000EASXUtp3LLFDepPort1Local | read-write | current | Local device card port 3 Link Loss Forwarding depends on port 1 Fiber Rx link: 0:don't care 1:selected |
| 1.3.6.1.4.1.4756.20.300.40.1.62 | Columnf1000EASXUtp3LLFDepPort2Local | read-write | current | Local device card port 3 Link Loss Forwarding depends on port 2 Fiber Rx link: 0:don't care 1:selected |
| 1.3.6.1.4.1.4756.20.300.40.1.63 | Columnf1000EASXUtp4LLFDepLogiLocal | read-write | current | Local device card port 4 Link Loss Forwarding depends boolean logic: 0:and 1:or |
| 1.3.6.1.4.1.4756.20.300.40.1.64 | Columnf1000EASXUtp4LLFDepPort1Local | read-write | current | Local device card port 4 Link Loss Forwarding depends on port 1 Fiber Rx link: 0:don't care 1:selected |
| 1.3.6.1.4.1.4756.20.300.40.1.65 | Columnf1000EASXUtp4LLFDepPort2Local | read-write | current | Local device card port 4 Link Loss Forwarding depends on port 2 Fiber Rx link: 0:don't care 1:selected |
| 1.3.6.1.4.1.4756.20.300.40.1.66 | Columnf1000EASXAdvanceFunsLocal | read-write | current | Local device card Switch functions mode: 0:Normal 1:Port 1 and Port 2 Trunk Bandwidth 2G 2:Port 1 to Port 2 Mirror 4:port 1 and port 2 Redundancy 5:Static 802.… |
| 1.3.6.1.4.1.4756.20.300.40.1.67 | Columnf1000EASXFiber1InfoROM1Local | read-only | current | Local device card port 1 INFORemoteOM information 1 valid: 0:Invalid 1:Valid |
| 1.3.6.1.4.1.4756.20.300.40.1.68 | Columnf1000EASXFiber1InfoROM2Local | read-only | current | Local device card port 1 INFORemoteOM information 2 valid: 0:Invalid 1:Valid(replacing D/D function |
| 1.3.6.1.4.1.4756.20.300.40.1.69 | Columnf1000EASXFiber2InfoROM1Local | read-only | current | Local device card port 2 INFORemoteOM information 1 valid: 0:Invalid 1:Valid |
| 1.3.6.1.4.1.4756.20.300.40.1.70 | Columnf1000EASXFiber2InfoROM2Local | read-only | current | Local device card port 2 INFORemoteOM information 2 valid: 0:Invalid 1:Valid(replacing D/D function) |
| 1.3.6.1.4.1.4756.20.300.40.1.71 | Columnf1000EASXFiber1InfoSN1Local | read-only | current | Local device card port 1 INFORemoteOM S/N 1 |
| 1.3.6.1.4.1.4756.20.300.40.1.72 | Columnf1000EASXFiber1InfoSN2Local | read-only | current | Local device card port 1 INFORemoteOM S/N 2 |
| 1.3.6.1.4.1.4756.20.300.40.1.73 | Columnf1000EASXFiber2InfoSN1Local | read-only | current | Local device card port 2 INFORemoteOM S/N 1 |
| 1.3.6.1.4.1.4756.20.300.40.1.74 | Columnf1000EASXFiber2InfoSN2Local | read-only | current | Local device card port 2 INFORemoteOM S/N 2 |
| 1.3.6.1.4.1.4756.20.300.40.1.75 | Columnf1000EASXFiber1DDLocal | read-only | current | Local device card fiber port 1 Digital Diagnostic function: 0:No 1:Yes |
| 1.3.6.1.4.1.4756.20.300.40.1.76 | Columnf1000EASXFiber1DDVendorLocal | read-only | current | Local device card fiber port 1 D/D information: Vendor name |
| 1.3.6.1.4.1.4756.20.300.40.1.77 | Columnf1000EASXFiber1DDPartNoLocal | read-only | current | Local device card fiber port 1 D/D information: Vendor part number |
| 1.3.6.1.4.1.4756.20.300.40.1.78 | Columnf1000EASXFiber1DDVendorSNLocal | read-only | current | Local device card fiber port 1 D/D information: Vendor Serial Number |
| 1.3.6.1.4.1.4756.20.300.40.1.79 | Columnf1000EASXFiber1DDFiberTypeLocal | read-only | current | Local device card fiber port 1 D/D information: Fiber Type |
| 1.3.6.1.4.1.4756.20.300.40.1.80 | Columnf1000EASXFiber1DDWaveLenLocal | read-only | current | Local device card fiber port 1 D/D information: Wave length |
| 1.3.6.1.4.1.4756.20.300.40.1.81 | Columnf1000EASXFiber1DDWaveLen2Local | read-only | current | Local device card fiber port 1 D/D information: Wave length 2 |
| 1.3.6.1.4.1.4756.20.300.40.1.82 | Columnf1000EASXFiber1DDLinkLenLocal | read-only | current | Local device card fiber port 1 D/D information: Link length |
| 1.3.6.1.4.1.4756.20.300.40.1.83 | Columnf1000EASXFiber1DDLenUnitLocal | read-only | current | Local device card fiber port 1 D/D information: Length Unit |
| 1.3.6.1.4.1.4756.20.300.40.1.84 | Columnf1000EASXFiber1DDStatusLocal | read-only | current | Local device card fiber port 1 D/D information: Status Support |
| 1.3.6.1.4.1.4756.20.300.40.1.85 | Columnf1000EASXFiber1DDRxSensLocal | read-only | current | Local device card fiber port 1 D/D information: Rx Sensitivity |
| 1.3.6.1.4.1.4756.20.300.40.1.86 | Columnf1000EASXFiber1DDTxPWRLocal | read-only | current | Local device card fiber port 1 D/D information: Tx power |
| 1.3.6.1.4.1.4756.20.300.40.1.87 | Columnf1000EASXFiber1DDRxPWRLocal | read-only | current | Local device card fiber port 1 D/D information: Rx power |
| 1.3.6.1.4.1.4756.20.300.40.1.88 | Columnf1000EASXFiber1DDTempLocal | read-only | current | Local device card fiber port 1 D/D information: Temperature in degree C |
| 1.3.6.1.4.1.4756.20.300.40.1.89 | Columnf1000EASXFiber1DDPWRMarginLocal | read-only | current | Local device card fiber port 1 D/D information: Power margin |
| 1.3.6.1.4.1.4756.20.300.40.1.90 | Columnf1000EASXFiber1DDPWRLossLocal | read-only | current | Local device card fiber port 1 D/D information: Power loss |
| 1.3.6.1.4.1.4756.20.300.40.1.91 | Columnf1000EASXFiber2DDLocal | read-only | current | Local device card fiber port 2 Digital Diagnostic function: 0:No 1:Yes |
| 1.3.6.1.4.1.4756.20.300.40.1.92 | Columnf1000EASXFiber2DDVendorLocal | read-only | current | Local device card fiber port 2 D/D information: Vendor name |
| 1.3.6.1.4.1.4756.20.300.40.1.93 | Columnf1000EASXFiber2DDPartNoLocal | read-only | current | Local device card fiber port 2 D/D information: Vendor part number |
| 1.3.6.1.4.1.4756.20.300.40.1.94 | Columnf1000EASXFiber2DDVendorSNLocal | read-only | current | Local device card fiber port 2 D/D information: Vendor Serial Number |
| 1.3.6.1.4.1.4756.20.300.40.1.95 | Columnf1000EASXFiber2DDFiberTypeLocal | read-only | current | Local device card fiber port 2 D/D information: Fiber Type |
| 1.3.6.1.4.1.4756.20.300.40.1.96 | Columnf1000EASXFiber2DDWaveLenLocal | read-only | current | Local device card fiber port 2 D/D information: Wave length |
| 1.3.6.1.4.1.4756.20.300.40.1.97 | Columnf1000EASXFiber2DDWaveLen2Local | read-only | current | Local device card fiber port 2 D/D information: Wave length 2 |
| 1.3.6.1.4.1.4756.20.300.40.1.98 | Columnf1000EASXFiber2DDLinkLenLocal | read-only | current | Local device card fiber port 2 D/D information: Link length |
| 1.3.6.1.4.1.4756.20.300.40.1.99 | Columnf1000EASXFiber2DDLenUnitLocal | read-only | current | Local device card fiber port 2 D/D information: Length Unit |
| 1.3.6.1.4.1.4756.20.300.40.1.100 | Columnf1000EASXFiber2DDStatusLocal | read-only | current | Local device card fiber port 2 D/D information: Status Support |
| 1.3.6.1.4.1.4756.20.300.40.1.101 | Columnf1000EASXFiber2DDRxSensLocal | read-only | current | Local device card fiber port 2 D/D information: Rx Sensitivity |
| 1.3.6.1.4.1.4756.20.300.40.1.102 | Columnf1000EASXFiber2DDTxPWRLocal | read-only | current | Local device card fiber port 2 D/D information: Tx power |
| 1.3.6.1.4.1.4756.20.300.40.1.103 | Columnf1000EASXFiber2DDRxPWRLocal | read-only | current | Local device card fiber port 2 D/D information: Rx power |
| 1.3.6.1.4.1.4756.20.300.40.1.104 | Columnf1000EASXFiber2DDTempLocal | read-only | current | Local device card fiber port 2 D/D information: Temperature in degree C |
| 1.3.6.1.4.1.4756.20.300.40.1.105 | Columnf1000EASXFiber2DDPWRMarginLocal | read-only | current | Local device card fiber port 2 D/D information: Power margin |
| 1.3.6.1.4.1.4756.20.300.40.1.106 | Columnf1000EASXFiber2DDPWRLossLocal | read-only | current | Local device card fiber port 2 D/D information: Power loss |
| 1.3.6.1.4.1.4756.20.300.40.1.107 | Columnf1000EASXClrRMONCntsLocal | read-write | current | Clear local device card RMON IN/OUT counters: 0:No action 1:Action |
| 1.3.6.1.4.1.4756.20.300.40.1.108 | Columnf1000EASXFiber1RMONInLocal | read-only | current | Local device card port 1 RMON IN counter. |
| 1.3.6.1.4.1.4756.20.300.40.1.109 | Columnf1000EASXFiber1RMONOutLocal | read-only | current | Local device card port 1 RMON OUT counter. |
| 1.3.6.1.4.1.4756.20.300.40.1.110 | Columnf1000EASXFiber2RMONInLocal | read-only | current | Local device card port 2 RMON IN counter. |
| 1.3.6.1.4.1.4756.20.300.40.1.111 | Columnf1000EASXFiber2RMONOutLocal | read-only | current | Local device card port 2 RMON OUT counter. |
| 1.3.6.1.4.1.4756.20.300.40.1.112 | Columnf1000EASXUtp3RMONInLocal | read-only | current | Local device card port 3 RMON IN counter. |
| 1.3.6.1.4.1.4756.20.300.40.1.113 | Columnf1000EASXUtp3RMONOutLocal | read-only | current | Local device card port 3 RMON OUT counter. |
| 1.3.6.1.4.1.4756.20.300.40.1.114 | Columnf1000EASXUtp4RMONInLocal | read-only | current | Local device card port 4 RMON IN counter. |
| 1.3.6.1.4.1.4756.20.300.40.1.115 | Columnf1000EASXUtp4RMONOutLocal | read-only | current | Local device card port 4 RMON OUT counter. |
| 1.3.6.1.4.1.4756.20.300.40.1.116 | Columnf1000EASXClrOAMCntsLocal | read-write | current | Clear local device card OAM counters: 0:No action 1:Action |
| 1.3.6.1.4.1.4756.20.300.40.1.117 | Columnf1000EASXIpModeLocal | read-write | current | On Rack Ip Mode: 0:Enable 1:Disable |
| 1.3.6.1.4.1.4756.20.300.40.1.118 | Columnf1000EASXOamChATxLocal | read-only | current | Local device OAM Channel A TX OAMPDU frame count |
| 1.3.6.1.4.1.4756.20.300.40.1.119 | Columnf1000EASXOamChARxLocal | read-only | current | Local device OAM Channel A RX OAMPDU frame count |
| 1.3.6.1.4.1.4756.20.300.40.1.120 | Columnf1000EASXOamInfoChATxLocal | read-only | current | Local device OAM Channel A TX Information OAMPDU frame count |
| 1.3.6.1.4.1.4756.20.300.40.1.121 | Columnf1000EASXOamInfoChARxLocal | read-only | current | Local device OAM Channel A RX Information OAMPDU frame count |
| 1.3.6.1.4.1.4756.20.300.40.1.122 | Columnf1000EASXOamEventChATxLocal | read-only | current | Local device OAM Channel A TX Event OAMPDU frame count |
| 1.3.6.1.4.1.4756.20.300.40.1.123 | Columnf1000EASXOamUniEvtChARxLocal | read-only | current | Local device OAM Channel A RX Unique Event OAMPDU frame count |
| 1.3.6.1.4.1.4756.20.300.40.1.124 | Columnf1000EASXOamDupEvtChARxLocal | read-only | current | Local device OAM Channel A RX Duplicate Event OAMPDU frame count |
| 1.3.6.1.4.1.4756.20.300.40.1.125 | Columnf1000EASXOamLbChATxLocal | read-only | current | Local device OAM Channel A TX Loopback Control OAMPDU frame count |
| 1.3.6.1.4.1.4756.20.300.40.1.126 | Columnf1000EASXOamLbChARxLocal | read-only | current | Local device OAM Channel A RX Loopback Control OAMPDU frame count |
| 1.3.6.1.4.1.4756.20.300.40.1.127 | Columnf1000EASXOamVarReqChATxLocal | read-only | current | Local device OAM Channel A TX Variable Request OAMPDU frame count |
| 1.3.6.1.4.1.4756.20.300.40.1.128 | Columnf1000EASXOamVarReqChARxLocal | read-only | current | Local device OAM Channel A RX Variable Request OAMPDU frame count |
| 1.3.6.1.4.1.4756.20.300.40.1.129 | Columnf1000EASXOamVarRspChATxLocal | read-only | current | Local device OAM Channel A TX Variable Response OAMPDU frame count |
| 1.3.6.1.4.1.4756.20.300.40.1.130 | Columnf1000EASXOamVarRspChARxLocal | read-only | current | Local device OAM Channel A RX Variable Response OAMPDU frame count |
| 1.3.6.1.4.1.4756.20.300.40.1.131 | Columnf1000EASXOamOuiChATxLocal | read-only | current | Local device OAM Channel A TX OUI OAMPDU frame count |
| 1.3.6.1.4.1.4756.20.300.40.1.132 | Columnf1000EASXOamOuiChARxLocal | read-only | current | Local device OAM Channel A RX OUI OAMPDU frame count |
| 1.3.6.1.4.1.4756.20.300.40.1.133 | Columnf1000EASXOamUnknowChARxLocal | read-only | current | Local device OAM Channel A RX Unsupported OAMPDU frame count |
| 1.3.6.1.4.1.4756.20.300.40.1.134 | Columnf1000EASXOamChBTxLocal | read-only | current | Local device OAM Channel B TX OAMPDU frame count |
| 1.3.6.1.4.1.4756.20.300.40.1.135 | Columnf1000EASXOamChBRxLocal | read-only | current | Local device OAM Channel B RX OAMPDU frame count |
| 1.3.6.1.4.1.4756.20.300.40.1.136 | Columnf1000EASXOamInfoChBTxLocal | read-only | current | Local device OAM Channel B TX Information OAMPDU frame count |
| 1.3.6.1.4.1.4756.20.300.40.1.137 | Columnf1000EASXOamInfoChBRxLocal | read-only | current | Local device OAM Channel B RX Information OAMPDU frame count |
| 1.3.6.1.4.1.4756.20.300.40.1.138 | Columnf1000EASXOamEventChBTxLocal | read-only | current | Local device OAM Channel B TX Event OAMPDU frame count |
| 1.3.6.1.4.1.4756.20.300.40.1.139 | Columnf1000EASXOamUniEvtChBRxLocal | read-only | current | Local device OAM Channel B RX Unique Event OAMPDU frame count |
| 1.3.6.1.4.1.4756.20.300.40.1.140 | Columnf1000EASXOamDupEvtChBRxLocal | read-only | current | Local device OAM Channel B RX Duplicate Event OAMPDU frame count |
| 1.3.6.1.4.1.4756.20.300.40.1.141 | Columnf1000EASXOamLbChBTxLocal | read-only | current | Local device OAM Channel B TX Loopback Control OAMPDU frame count |
| 1.3.6.1.4.1.4756.20.300.40.1.142 | Columnf1000EASXOamLbChBRxLocal | read-only | current | Local device OAM Channel B RX Loopback Control OAMPDU frame count |
| 1.3.6.1.4.1.4756.20.300.40.1.143 | Columnf1000EASXOamVarReqChBTxLocal | read-only | current | Local device OAM Channel B TX Variable Request OAMPDU frame count |
| 1.3.6.1.4.1.4756.20.300.40.1.144 | Columnf1000EASXOamVarReqChBRxLocal | read-only | current | Local device OAM Channel B RX Variable Request OAMPDU frame count |
| 1.3.6.1.4.1.4756.20.300.40.1.145 | Columnf1000EASXOamVarRspChBTxLocal | read-only | current | Local device OAM Channel B TX Variable Response OAMPDU frame count |
| 1.3.6.1.4.1.4756.20.300.40.1.146 | Columnf1000EASXOamVarRspChBRxLocal | read-only | current | Local device OAM Channel B RX Variable Response OAMPDU frame count |
| 1.3.6.1.4.1.4756.20.300.40.1.147 | Columnf1000EASXOamOuiChBTxLocal | read-only | current | Local device OAM Channel B TX OUI OAMPDU frame count |
| 1.3.6.1.4.1.4756.20.300.40.1.148 | Columnf1000EASXOamOuiChBRxLocal | read-only | current | Local device OAM Channel B RX OUI OAMPDU frame count |
| 1.3.6.1.4.1.4756.20.300.40.1.149 | Columnf1000EASXOamUnknowChBRxLocal | read-only | current | Local device OAM Channel B RX Unsupported OAMPDU frame count |
| 1.3.6.1.4.1.4756.20.300.40.1.150 | Columnf1000EASXFiber1SpeedLocal | read-write | current | Local device Fiber 1 speed : 0:1000Auto 1:1000FDX 2:100FDX |
| 1.3.6.1.4.1.4756.20.300.40.1.151 | Columnf1000EASXFiber2SpeedLocal | read-write | current | Local device Fiber 2 speed : 0:1000Auto 1:1000FDX 2:100FDX |
| 1.3.6.1.4.1.4756.20.300.40.1.152 | Columnf1000EASXMacLearningLocal | read-write | current | Local device Mac learning : 0:Disable 1:Enable |
| 1.3.6.1.4.1.4756.20.300.40.1.153 | Columnf1000EASXFiber1VLANLocal | read-write | current | Local device Fiber 1 VLAN group : 0:Group A 1:Group B |
| 1.3.6.1.4.1.4756.20.300.40.1.154 | Columnf1000EASXFiber2VLANLocal | read-write | current | Local device Fiber 2 VLAN group : 0:Group A 1:Group B |
| 1.3.6.1.4.1.4756.20.300.40.1.155 | Columnf1000EASXUtp3VLANLocal | read-write | current | Local device UTP 3 VLAN group : 0:Group A 1:Group B |
| 1.3.6.1.4.1.4756.20.300.40.1.156 | Columnf1000EASXUtp4VLANLocal | read-write | current | Local device UTP 4 VLAN group : 0:Group A 1:Group B |
| 1.3.6.1.4.1.4756.20.300.40.1.157 | Columnf1000EASXManagementLocal | read-write | current | Local device management : 0:Group A 1:Group B 2:Group A+B |
| 1.3.6.1.4.1.4756.20.300.40.1.158 | Columnf1000EASXRedundancyModeLocal | read-write | current | Local device redundancy mode : 0:Auto 1:Manual Fiber 1 2:Manual Fiber 2 3:No Reverse 4:Link Budget |
| 1.3.6.1.4.1.4756.20.300.40.1.159 | Columnf1000EASXPortVLANLocal | read-write | current | Local device redundancy mode : 0:Disalbe 1:Enable |
| 1.3.6.1.4.1.4756.20.300.40.1.160 | Columnf1000EASXRemoteTLPTLocal | read-write | current | Local device redundancy mode : 0:Disalbe 1:Remote A 2:Remote B 3:Remote A&B 4:Remote A/3; Remote B/4 |
| 1.3.6.1.4.1.4756.20.300.40.1.161 | Columnf1000EASXManagementVIDLocal | read-write | current | Local device Management VID : |
| 1.3.6.1.4.1.4756.20.300.40.1.162 | Columnf1000EASXThresholdLocal | read-write | current | Local device Threshold: |
| 1.3.6.1.4.1.4756.20.300.40.1.163 | Columnf1000EASXSensitivityLocal | read-write | current | Local device Sensitivity: |
| 1.3.6.1.4.1.4756.20.300.40.1.164 | Columnf1000EASXTagTypeLocal | read-write | current | Local device Tag Type (HEX) : |
| 1.3.6.1.4.1.4756.20.300.40.1.165 | Columnf1000EASXPort1VIDLocal | read-write | current | Local device Port 1 VID : |
| 1.3.6.1.4.1.4756.20.300.40.1.166 | Columnf1000EASXPort2VIDLocal | read-write | current | Local device Port 2 VID : |
| 1.3.6.1.4.1.4756.20.300.40.1.167 | Columnf1000EASXPort3VIDLocal | read-write | current | Local device Port 3 VID : |
| 1.3.6.1.4.1.4756.20.300.40.1.168 | Columnf1000EASXPort4VIDLocal | read-write | current | Local device Port 4 VID : |
| 1.3.6.1.4.1.4756.20.300.40.1.169 | Columnf1000EASXPort1QinQLocal | read-write | current | Local device Port 1 Q in Q Support : 1:Disable 2:Enable |
| 1.3.6.1.4.1.4756.20.300.40.1.170 | Columnf1000EASXPort2QinQLocal | read-write | current | Local device Port 2 Q in Q Support : 1:Disable 2:Enable |
| 1.3.6.1.4.1.4756.20.300.40.1.171 | Columnf1000EASXPort3QinQLocal | read-write | current | Local device Port 3 Q in Q Support : 1:Disable 2:Enable |
| 1.3.6.1.4.1.4756.20.300.40.1.172 | Columnf1000EASXPort4QinQLocal | read-write | current | Local device Port 4 Q in Q Support : 1:Disable 2:Enable |
| 1.3.6.1.4.1.4756.20.300.40.1.173 | Columnf1000EASXVID1Local | read-write | current | Local device VID 1: |
| 1.3.6.1.4.1.4756.20.300.40.1.174 | Columnf1000EASXVID2Local | read-write | current | Local device VID 2: |
| 1.3.6.1.4.1.4756.20.300.40.1.175 | Columnf1000EASXVID3Local | read-write | current | Local device VID 3: |
| 1.3.6.1.4.1.4756.20.300.40.1.176 | Columnf1000EASXVID4Local | read-write | current | Local device VID 4: |
| 1.3.6.1.4.1.4756.20.300.40.1.177 | Columnf1000EASXVID5Local | read-write | current | Local device VID 5: |
| 1.3.6.1.4.1.4756.20.300.40.1.178 | Columnf1000EASXVID6Local | read-write | current | Local device VID 6: |
| 1.3.6.1.4.1.4756.20.300.40.1.179 | Columnf1000EASXVID7Local | read-write | current | Local device VID 7: |
| 1.3.6.1.4.1.4756.20.300.40.1.180 | Columnf1000EASXVID8Local | read-write | current | Local device VID 8: |
| 1.3.6.1.4.1.4756.20.300.40.1.181 | Columnf1000EASXVID9Local | read-write | current | Local device VID 9: |
| 1.3.6.1.4.1.4756.20.300.40.1.182 | Columnf1000EASXVID10Local | read-write | current | Local device VID 10: |
| 1.3.6.1.4.1.4756.20.300.40.1.183 | Columnf1000EASXVID11Local | read-write | current | Local device VID 11: |
| 1.3.6.1.4.1.4756.20.300.40.1.184 | Columnf1000EASXVID12Local | read-write | current | Local device VID 12: |
| 1.3.6.1.4.1.4756.20.300.40.1.185 | Columnf1000EASXVID13Local | read-write | current | Local device VID 13: |
| 1.3.6.1.4.1.4756.20.300.40.1.186 | Columnf1000EASXVID14Local | read-write | current | Local device VID 14: |
| 1.3.6.1.4.1.4756.20.300.40.1.187 | Columnf1000EASXVID15Local | read-write | current | Local device VID 15: |
| 1.3.6.1.4.1.4756.20.300.40.1.188 | Columnf1000EASXVID16Local | read-write | current | Local device VID 16: |
| 1.3.6.1.4.1.4756.20.300.40.1.189 | Columnf1000EASXPort1Member1Local | read-write | current | Local device card port 1 member: 0:Unmodify 1:Untagged 2:Tagged 3:Nonmember |
| 1.3.6.1.4.1.4756.20.300.40.1.190 | Columnf1000EASXPort1Member2Local | read-write | current | Local device card port 1 member 2: 0:Unmodify 1:Untagged 2:Tagged 3:Nonmember |
| 1.3.6.1.4.1.4756.20.300.40.1.191 | Columnf1000EASXPort1Member3Local | read-write | current | Local device card port 1 member 3: 0:Unmodify 1:Untagged 2:Tagged 3:Nonmember |
| 1.3.6.1.4.1.4756.20.300.40.1.192 | Columnf1000EASXPort1Member4Local | read-write | current | Local device card port 1 member 4: 0:Unmodify 1:Untagged 2:Tagged 3:Nonmember |
| 1.3.6.1.4.1.4756.20.300.40.1.193 | Columnf1000EASXPort1Member5Local | read-write | current | Local device card port 1 member 5: 0:Unmodify 1:Untagged 2:Tagged 3:Nonmember |
| 1.3.6.1.4.1.4756.20.300.40.1.194 | Columnf1000EASXPort1Member6Local | read-write | current | Local device card port 1 member 6: 0:Unmodify 1:Untagged 2:Tagged 3:Nonmember |
| 1.3.6.1.4.1.4756.20.300.40.1.195 | Columnf1000EASXPort1Member7Local | read-write | current | Local device card port 1 member 7: 0:Unmodify 1:Untagged 2:Tagged 3:Nonmember |
| 1.3.6.1.4.1.4756.20.300.40.1.196 | Columnf1000EASXPort1Member8Local | read-write | current | Local device card port 1 member 8: 0:Unmodify 1:Untagged 2:Tagged 3:Nonmember |
| 1.3.6.1.4.1.4756.20.300.40.1.197 | Columnf1000EASXPort1Member9Local | read-write | current | Local device card port 1 member 9: 0:Unmodify 1:Untagged 2:Tagged 3:Nonmember |
| 1.3.6.1.4.1.4756.20.300.40.1.198 | Columnf1000EASXPort1Member10Local | read-write | current | Local device card port 1 member 10: 0:Unmodify 1:Untagged 2:Tagged 3:Nonmember |
| 1.3.6.1.4.1.4756.20.300.40.1.199 | Columnf1000EASXPort1Member11Local | read-write | current | Local device card port 1 member 11: 0:Unmodify 1:Untagged 2:Tagged 3:Nonmember |
| 1.3.6.1.4.1.4756.20.300.40.1.200 | Columnf1000EASXPort1Member12Local | read-write | current | Local device card port 1 member 12: 0:Unmodify 1:Untagged 2:Tagged 3:Nonmember |
| 1.3.6.1.4.1.4756.20.300.40.1.201 | Columnf1000EASXPort1Member13Local | read-write | current | Local device card port 1 member 13: 0:Unmodify 1:Untagged 2:Tagged 3:Nonmember |
| 1.3.6.1.4.1.4756.20.300.40.1.202 | Columnf1000EASXPort1Member14Local | read-write | current | Local device card port 1 member 14: 0:Unmodify 1:Untagged 2:Tagged 3:Nonmember |
| 1.3.6.1.4.1.4756.20.300.40.1.203 | Columnf1000EASXPort1Member15Local | read-write | current | Local device card port 1 member 15: 0:Unmodify 1:Untagged 2:Tagged 3:Nonmember |
| 1.3.6.1.4.1.4756.20.300.40.1.204 | Columnf1000EASXPort1Member16Local | read-write | current | Local device card port 1 member 16: 0:Unmodify 1:Untagged 2:Tagged 3:Nonmember |
| 1.3.6.1.4.1.4756.20.300.40.1.205 | Columnf1000EASXPort2Member1Local | read-write | current | Local device card port 2 member: 0:Unmodify 1:Untagged 2:Tagged 3:Nonmember |
| 1.3.6.1.4.1.4756.20.300.40.1.206 | Columnf1000EASXPort2Member2Local | read-write | current | Local device card port 2 member 2: 0:Unmodify 1:Untagged 2:Tagged 3:Nonmember |
| 1.3.6.1.4.1.4756.20.300.40.1.207 | Columnf1000EASXPort2Member3Local | read-write | current | Local device card port 2 member 3: 0:Unmodify 1:Untagged 2:Tagged 3:Nonmember |
| 1.3.6.1.4.1.4756.20.300.40.1.208 | Columnf1000EASXPort2Member4Local | read-write | current | Local device card port 2 member 4: 0:Unmodify 1:Untagged 2:Tagged 3:Nonmember |
| 1.3.6.1.4.1.4756.20.300.40.1.209 | Columnf1000EASXPort2Member5Local | read-write | current | Local device card port 2 member 5: 0:Unmodify 1:Untagged 2:Tagged 3:Nonmember |
| 1.3.6.1.4.1.4756.20.300.40.1.210 | Columnf1000EASXPort2Member6Local | read-write | current | Local device card port 2 member 6: 0:Unmodify 1:Untagged 2:Tagged 3:Nonmember |
| 1.3.6.1.4.1.4756.20.300.40.1.211 | Columnf1000EASXPort2Member7Local | read-write | current | Local device card port 2 member 7: 0:Unmodify 1:Untagged 2:Tagged 3:Nonmember |
| 1.3.6.1.4.1.4756.20.300.40.1.212 | Columnf1000EASXPort2Member8Local | read-write | current | Local device card port 2 member 8: 0:Unmodify 1:Untagged 2:Tagged 3:Nonmember |
| 1.3.6.1.4.1.4756.20.300.40.1.213 | Columnf1000EASXPort2Member9Local | read-write | current | Local device card port 2 member 9: 0:Unmodify 1:Untagged 2:Tagged 3:Nonmember |
| 1.3.6.1.4.1.4756.20.300.40.1.214 | Columnf1000EASXPort2Member10Local | read-write | current | Local device card port 2 member 10: 0:Unmodify 1:Untagged 2:Tagged 3:Nonmember |
| 1.3.6.1.4.1.4756.20.300.40.1.215 | Columnf1000EASXPort2Member11Local | read-write | current | Local device card port 2 member 11: 0:Unmodify 1:Untagged 2:Tagged 3:Nonmember |
| 1.3.6.1.4.1.4756.20.300.40.1.216 | Columnf1000EASXPort2Member12Local | read-write | current | Local device card port 2 member 12: 0:Unmodify 1:Untagged 2:Tagged 3:Nonmember |
| 1.3.6.1.4.1.4756.20.300.40.1.217 | Columnf1000EASXPort2Member13Local | read-write | current | Local device card port 2 member 13: 0:Unmodify 1:Untagged 2:Tagged 3:Nonmember |
| 1.3.6.1.4.1.4756.20.300.40.1.218 | Columnf1000EASXPort2Member14Local | read-write | current | Local device card port 2 member 14: 0:Unmodify 1:Untagged 2:Tagged 3:Nonmember |
| 1.3.6.1.4.1.4756.20.300.40.1.219 | Columnf1000EASXPort2Member15Local | read-write | current | Local device card port 2 member 15: 0:Unmodify 1:Untagged 2:Tagged 3:Nonmember |
| 1.3.6.1.4.1.4756.20.300.40.1.220 | Columnf1000EASXPort2Member16Local | read-write | current | Local device card port 2 member 16: 0:Unmodify 1:Untagged 2:Tagged 3:Nonmember |
| 1.3.6.1.4.1.4756.20.300.40.1.221 | Columnf1000EASXPort3Member1Local | read-write | current | Local device card port 3 member: 0:Unmodify 1:Untagged 2:Tagged 3:Nonmember |
| 1.3.6.1.4.1.4756.20.300.40.1.222 | Columnf1000EASXPort3Member2Local | read-write | current | Local device card port 3 member 2: 0:Unmodify 1:Untagged 2:Tagged 3:Nonmember |
| 1.3.6.1.4.1.4756.20.300.40.1.223 | Columnf1000EASXPort3Member3Local | read-write | current | Local device card port 3 member 3: 0:Unmodify 1:Untagged 2:Tagged 3:Nonmember |
| 1.3.6.1.4.1.4756.20.300.40.1.224 | Columnf1000EASXPort3Member4Local | read-write | current | Local device card port 3 member 4: 0:Unmodify 1:Untagged 2:Tagged 3:Nonmember |
| 1.3.6.1.4.1.4756.20.300.40.1.225 | Columnf1000EASXPort3Member5Local | read-write | current | Local device card port 3 member 5: 0:Unmodify 1:Untagged 2:Tagged 3:Nonmember |
| 1.3.6.1.4.1.4756.20.300.40.1.226 | Columnf1000EASXPort3Member6Local | read-write | current | Local device card port 3 member 6: 0:Unmodify 1:Untagged 2:Tagged 3:Nonmember |
| 1.3.6.1.4.1.4756.20.300.40.1.227 | Columnf1000EASXPort3Member7Local | read-write | current | Local device card port 3 member 7: 0:Unmodify 1:Untagged 2:Tagged 3:Nonmember |
| 1.3.6.1.4.1.4756.20.300.40.1.228 | Columnf1000EASXPort3Member8Local | read-write | current | Local device card port 3 member 8: 0:Unmodify 1:Untagged 2:Tagged 3:Nonmember |
| 1.3.6.1.4.1.4756.20.300.40.1.229 | Columnf1000EASXPort3Member9Local | read-write | current | Local device card port 3 member 9: 0:Unmodify 1:Untagged 2:Tagged 3:Nonmember |
| 1.3.6.1.4.1.4756.20.300.40.1.230 | Columnf1000EASXPort3Member10Local | read-write | current | Local device card port 3 member 10: 0:Unmodify 1:Untagged 2:Tagged 3:Nonmember |
| 1.3.6.1.4.1.4756.20.300.40.1.231 | Columnf1000EASXPort3Member11Local | read-write | current | Local device card port 3 member 11: 0:Unmodify 1:Untagged 2:Tagged 3:Nonmember |
| 1.3.6.1.4.1.4756.20.300.40.1.232 | Columnf1000EASXPort3Member12Local | read-write | current | Local device card port 3 member 12: 0:Unmodify 1:Untagged 2:Tagged 3:Nonmember |
| 1.3.6.1.4.1.4756.20.300.40.1.233 | Columnf1000EASXPort3Member13Local | read-write | current | Local device card port 3 member 13: 0:Unmodify 1:Untagged 2:Tagged 3:Nonmember |
| 1.3.6.1.4.1.4756.20.300.40.1.234 | Columnf1000EASXPort3Member14Local | read-write | current | Local device card port 3 member 14: 0:Unmodify 1:Untagged 2:Tagged 3:Nonmember |
| 1.3.6.1.4.1.4756.20.300.40.1.235 | Columnf1000EASXPort3Member15Local | read-write | current | Local device card port 3 member 15: 0:Unmodify 1:Untagged 2:Tagged 3:Nonmember |
| 1.3.6.1.4.1.4756.20.300.40.1.236 | Columnf1000EASXPort3Member16Local | read-write | current | Local device card port 3 member 16: 0:Unmodify 1:Untagged 2:Tagged 3:Nonmember |
| 1.3.6.1.4.1.4756.20.300.40.1.237 | Columnf1000EASXPort4Member1Local | read-write | current | Local device card port 4 member: 0:Unmodify 1:Untagged 2:Tagged 3:Nonmember |
| 1.3.6.1.4.1.4756.20.300.40.1.238 | Columnf1000EASXPort4Member2Local | read-write | current | Local device card port 4 member 2: 0:Unmodify 1:Untagged 2:Tagged 3:Nonmember |
| 1.3.6.1.4.1.4756.20.300.40.1.239 | Columnf1000EASXPort4Member3Local | read-write | current | Local device card port 4 member 3: 0:Unmodify 1:Untagged 2:Tagged 3:Nonmember |
| 1.3.6.1.4.1.4756.20.300.40.1.240 | Columnf1000EASXPort4Member4Local | read-write | current | Local device card port 4 member 4: 0:Unmodify 1:Untagged 2:Tagged 3:Nonmember |
| 1.3.6.1.4.1.4756.20.300.40.1.241 | Columnf1000EASXPort4Member5Local | read-write | current | Local device card port 4 member 5: 0:Unmodify 1:Untagged 2:Tagged 3:Nonmember |
| 1.3.6.1.4.1.4756.20.300.40.1.242 | Columnf1000EASXPort4Member6Local | read-write | current | Local device card port 4 member 6: 0:Unmodify 1:Untagged 2:Tagged 3:Nonmember |
| 1.3.6.1.4.1.4756.20.300.40.1.243 | Columnf1000EASXPort4Member7Local | read-write | current | Local device card port 4 member 7: 0:Unmodify 1:Untagged 2:Tagged 3:Nonmember |
| 1.3.6.1.4.1.4756.20.300.40.1.244 | Columnf1000EASXPort4Member8Local | read-write | current | Local device card port 4 member 8: 0:Unmodify 1:Untagged 2:Tagged 3:Nonmember |
| 1.3.6.1.4.1.4756.20.300.40.1.245 | Columnf1000EASXPort4Member9Local | read-write | current | Local device card port 4 member 9: 0:Unmodify 1:Untagged 2:Tagged 3:Nonmember |
| 1.3.6.1.4.1.4756.20.300.40.1.246 | Columnf1000EASXPort4Member10Local | read-write | current | Local device card port 4 member 10: 0:Unmodify 1:Untagged 2:Tagged 3:Nonmember |
| 1.3.6.1.4.1.4756.20.300.40.1.247 | Columnf1000EASXPort4Member11Local | read-write | current | Local device card port 4 member 11: 0:Unmodify 1:Untagged 2:Tagged 3:Nonmember |
| 1.3.6.1.4.1.4756.20.300.40.1.248 | Columnf1000EASXPort4Member12Local | read-write | current | Local device card port 4 member 12: 0:Unmodify 1:Untagged 2:Tagged 3:Nonmember |
| 1.3.6.1.4.1.4756.20.300.40.1.249 | Columnf1000EASXPort4Member13Local | read-write | current | Local device card port 4 member 13: 0:Unmodify 1:Untagged 2:Tagged 3:Nonmember |
| 1.3.6.1.4.1.4756.20.300.40.1.250 | Columnf1000EASXPort4Member14Local | read-write | current | Local device card port 4 member 14: 0:Unmodify 1:Untagged 2:Tagged 3:Nonmember |
| 1.3.6.1.4.1.4756.20.300.40.1.251 | Columnf1000EASXPort4Member15Local | read-write | current | Local device card port 4 member 15: 0:Unmodify 1:Untagged 2:Tagged 3:Nonmember |
| 1.3.6.1.4.1.4756.20.300.40.1.252 | Columnf1000EASXPort4Member16Local | read-write | current | Local device card port 4 member 16: 0:Unmodify 1:Untagged 2:Tagged 3:Nonmember |
| 1.3.6.1.4.1.4756.20.300.40.1.253 | Columnf1000EASXIpAddressLocal | read-write | current | Local device IP address |
| 1.3.6.1.4.1.4756.20.300.40.1.254 | Columnf1000EASXNetMaskLocal | read-write | current | Local device Netmask |
| 1.3.6.1.4.1.4756.20.300.40.1.255 | Columnf1000EASXGateWayLocal | read-write | current | Local device Gateway |
| 1.3.6.1.4.1.4756.20.300.40.1.256 | Columnf1000EASXSetDefaultLocal | read-write | current | Local device set to default |
| 1.3.6.1.4.1.4756.20.300.40.1.257 | Columnf1000EASXFx1LinkAlarmLocal | read-write | current | Local device fiber 1 link alarm 0:Disable 1:Enable |
| 1.3.6.1.4.1.4756.20.300.40.1.258 | Columnf1000EASXFx2LinkAlarmLocal | read-write | current | Local device fiber 2 link alarm 0:Disable 1:Enable |
| 1.3.6.1.4.1.4756.20.300.40.1.259 | Columnf1000EASXUtp3LinkAlarmLocal | read-write | current | Local device utp 3 link alarm 0:Disable 1:Enable |
| 1.3.6.1.4.1.4756.20.300.40.1.260 | Columnf1000EASXUtp4LinkAlarmLocal | read-write | current | Local device utp 4 link alarm 0:Disable 1:Enable |
| 1.3.6.1.4.1.4756.20.300.40.1.261 | Columnf1000EASXFiber1FEFLocal | read-only | current | Local device card fiber1 port FEF status: 0:Off 1:Detected |
| 1.3.6.1.4.1.4756.20.300.40.1.262 | Columnf1000EASXFiber2FEFLocal | read-only | current | Local device card fiber2 port FEF status: 0:Off 1:Detected |
| 1.3.6.1.4.1.4756.20.300.40.1.263 | Columnf1000EASXPingStatusLocal | read-only | current | Local device icmp ping status Show Ping Status 0: Normal 1: Not Ready 2: 5 packets transmitted, 5 received, 0 packet loss. (Ping OK) 3: 5 packets transmitted, … |
| 1.3.6.1.4.1.4756.20.300.40.1.264 | Columnf1000EASXPingIpAddressLocal | read-write | current | Local device ping IP address |
| 1.3.6.1.4.1.4756.20.300.40.1.265 | Columnf1000EASXPingStartLocal | read-write | current | Local device ping start 0:Off 1:Action |
| 1.3.6.1.4.1.4756.20.300.40.1.266 | Columnf1000EASXFX1RXOctetsLocal | read-only | current | FRM220-1000EAS/X RMON Fiber 1 Receiver Octets. |
| 1.3.6.1.4.1.4756.20.300.40.1.267 | Columnf1000EASXFX1RXPacketLocal | read-only | current | FRM220-1000EAS/X RMON Fiber 1 Receiver Packets. |
| 1.3.6.1.4.1.4756.20.300.40.1.268 | Columnf1000EASXFX1RXBroadLocal | read-only | current | FRM220-1000EAS/X RMON Fiber 1 Receiver Broadcast Packets. |
| 1.3.6.1.4.1.4756.20.300.40.1.269 | Columnf1000EASXFX1RXMultiLocal | read-only | current | FRM220-1000EAS/X RMON Fiber 1 Receiver Multicast Packets. |
| 1.3.6.1.4.1.4756.20.300.40.1.270 | Columnf1000EASXFX1RXUniLocal | read-only | current | FRM220-1000EAS/X RMON Fiber 1 Receiver Unicast Packets. |
| 1.3.6.1.4.1.4756.20.300.40.1.271 | Columnf1000EASXFX1RXPauseLocal | read-only | current | FRM220-1000EAS/X RMON Fiber 1 Receiver Pause Packets. |
| 1.3.6.1.4.1.4756.20.300.40.1.272 | Columnf1000EASXFX1RXFCSELocal | read-only | current | FRM220-1000EAS/X RMON Fiber 1 Receiver FCS Error Packets. |
| 1.3.6.1.4.1.4756.20.300.40.1.273 | Columnf1000EASXFX1RXUnderLocal | read-only | current | FRM220-1000EAS/X RMON Fiber 1 Receiver Under Packets. |
| 1.3.6.1.4.1.4756.20.300.40.1.274 | Columnf1000EASXFX1RXOverLocal | read-only | current | FRM220-1000EAS/X RMON Fiber 1 Receiver Over Packets. |
| 1.3.6.1.4.1.4756.20.300.40.1.275 | Columnf1000EASXFX1RXJabberLocal | read-only | current | FRM220-1000EAS/X RMON Fiber 1 Receiver Jabber Packets. |
| 1.3.6.1.4.1.4756.20.300.40.1.276 | Columnf1000EASXFX1TXOctetsLocal | read-only | current | FRM220-1000EAS/X RMON Fiber 1 Transceiver Octets. |
| 1.3.6.1.4.1.4756.20.300.40.1.277 | Columnf1000EASXFX1TXPacketLocal | read-only | current | FRM220-1000EAS/X RMON Fiber 1 Transceiver Packets. |
| 1.3.6.1.4.1.4756.20.300.40.1.278 | Columnf1000EASXFX1TXBroadLocal | read-only | current | FRM220-1000EAS/X RMON Fiber 1 Transceiver Broadcast Packets. |
| 1.3.6.1.4.1.4756.20.300.40.1.279 | Columnf1000EASXFX1TXMultiLocal | read-only | current | FRM220-1000EAS/X RMON Fiber 1 Transceiver Multicast Packets. |
| 1.3.6.1.4.1.4756.20.300.40.1.280 | Columnf1000EASXFX1TXUniLocal | read-only | current | FRM220-1000EAS/X RMON Fiber 1 Transceiver Unicast Packets. |
| 1.3.6.1.4.1.4756.20.300.40.1.281 | Columnf1000EASXFX1TXPauseLocal | read-only | current | FRM220-1000EAS/X RMON Fiber 1 Transceiver Pause Packets. |
| 1.3.6.1.4.1.4756.20.300.40.1.282 | Columnf1000EASXFX1TXCollisionLocal | read-only | current | FRM220-1000EAS/X RMON Fiber 1 Transceiver Collision Packets. |
| 1.3.6.1.4.1.4756.20.300.40.1.283 | Columnf1000EASXFX10OctetsLocal | read-only | current | FRM220-1000EAS/X RMON Fiber 1 Transceiver/Receiver 0~64 Octets. |
| 1.3.6.1.4.1.4756.20.300.40.1.284 | Columnf1000EASXFX165OctetsLocal | read-only | current | FRM220-1000EAS/X RMON Fiber 1 Transceiver/Receiver 65~127 Octets. |
| 1.3.6.1.4.1.4756.20.300.40.1.285 | Columnf1000EASXFX1128OctetsLocal | read-only | current | FRM220-1000EAS/X RMON Fiber 1 Transceiver/Receiver 128~255 Octets. |
| 1.3.6.1.4.1.4756.20.300.40.1.286 | Columnf1000EASXFX1256OctetsLocal | read-only | current | FRM220-1000EAS/X RMON Fiber 1 Transceiver/Receiver 256~511 Octets. |
| 1.3.6.1.4.1.4756.20.300.40.1.287 | Columnf1000EASXFX1512OctetsLocal | read-only | current | FRM220-1000EAS/X RMON Fiber 1 Transceiver/Receiver 512~1023 Octets. |
| 1.3.6.1.4.1.4756.20.300.40.1.288 | Columnf1000EASXFX11024OctetsLocal | read-only | current | FRM220-1000EAS/X RMON Fiber 1 Transceiver/Receiver 1024~Max Octets. |
| 1.3.6.1.4.1.4756.20.300.40.1.289 | Columnf1000EASXFX2RXOctetsLocal | read-only | current | FRM220-1000EAS/X RMON Fiber 2 Receiver Octets. |
| 1.3.6.1.4.1.4756.20.300.40.1.290 | Columnf1000EASXFX2RXPacketLocal | read-only | current | FRM220-1000EAS/X RMON Fiber 2 Receiver Packets. |
| 1.3.6.1.4.1.4756.20.300.40.1.291 | Columnf1000EASXFX2RXBroadLocal | read-only | current | FRM220-1000EAS/X RMON Fiber 2 Receiver Broadcast Packets. |
| 1.3.6.1.4.1.4756.20.300.40.1.292 | Columnf1000EASXFX2RXMultiLocal | read-only | current | FRM220-1000EAS/X RMON Fiber 2 Receiver Multicast Packets. |
| 1.3.6.1.4.1.4756.20.300.40.1.293 | Columnf1000EASXFX2RXUniLocal | read-only | current | FRM220-1000EAS/X RMON Fiber 2 Receiver Unicast Packets. |
| 1.3.6.1.4.1.4756.20.300.40.1.294 | Columnf1000EASXFX2RXPauseLocal | read-only | current | FRM220-1000EAS/X RMON Fiber 2 Receiver Pause Packets. |
| 1.3.6.1.4.1.4756.20.300.40.1.295 | Columnf1000EASXFX2RXFCSELocal | read-only | current | FRM220-1000EAS/X RMON Fiber 2 Receiver FCS Error Packets. |
| 1.3.6.1.4.1.4756.20.300.40.1.296 | Columnf1000EASXFX2RXUnderLocal | read-only | current | FRM220-1000EAS/X RMON Fiber 2 Receiver Under Packets. |
| 1.3.6.1.4.1.4756.20.300.40.1.297 | Columnf1000EASXFX2RXOverLocal | read-only | current | FRM220-1000EAS/X RMON Fiber 2 Receiver Over Packets. |
| 1.3.6.1.4.1.4756.20.300.40.1.298 | Columnf1000EASXFX2RXJabberLocal | read-only | current | FRM220-1000EAS/X RMON Fiber 2 Receiver Jabber Packets. |
| 1.3.6.1.4.1.4756.20.300.40.1.299 | Columnf1000EASXFX2TXOctetsLocal | read-only | current | FRM220-1000EAS/X RMON Fiber 2 Transceiver Octets. |
| 1.3.6.1.4.1.4756.20.300.40.1.300 | Columnf1000EASXFX2TXPacketLocal | read-only | current | FRM220-1000EAS/X RMON Fiber 2 Transceiver Packets. |
| 1.3.6.1.4.1.4756.20.300.40.1.301 | Columnf1000EASXFX2TXBroadLocal | read-only | current | FRM220-1000EAS/X RMON Fiber 2 Transceiver Broadcast Packets. |
| 1.3.6.1.4.1.4756.20.300.40.1.302 | Columnf1000EASXFX2TXMultiLocal | read-only | current | FRM220-1000EAS/X RMON Fiber 2 Transceiver Multicast Packets. |
| 1.3.6.1.4.1.4756.20.300.40.1.303 | Columnf1000EASXFX2TXUniLocal | read-only | current | FRM220-1000EAS/X RMON Fiber 2 Transceiver Unicast Packets. |
| 1.3.6.1.4.1.4756.20.300.40.1.304 | Columnf1000EASXFX2TXPauseLocal | read-only | current | FRM220-1000EAS/X RMON Fiber 2 Transceiver Pause Packets. |
| 1.3.6.1.4.1.4756.20.300.40.1.305 | Columnf1000EASXFX2TXCollisionLocal | read-only | current | FRM220-1000EAS/X RMON Fiber 2 Transceiver Collision Packets. |
| 1.3.6.1.4.1.4756.20.300.40.1.306 | Columnf1000EASXFX20OctetsLocal | read-only | current | FRM220-1000EAS/X RMON Fiber 2 Transceiver/Receiver 0~64 Octets. |
| 1.3.6.1.4.1.4756.20.300.40.1.307 | Columnf1000EASXFX265OctetsLocal | read-only | current | FRM220-1000EAS/X RMON Fiber 2 Transceiver/Receiver 65~127 Octets. |
| 1.3.6.1.4.1.4756.20.300.40.1.308 | Columnf1000EASXFX2128OctetsLocal | read-only | current | FRM220-1000EAS/X RMON Fiber 2 Transceiver/Receiver 128~255 Octets. |
| 1.3.6.1.4.1.4756.20.300.40.1.309 | Columnf1000EASXFX2256OctetsLocal | read-only | current | FRM220-1000EAS/X RMON Fiber 2 Transceiver/Receiver 256~511 Octets. |
| 1.3.6.1.4.1.4756.20.300.40.1.310 | Columnf1000EASXFX2512OctetsLocal | read-only | current | FRM220-1000EAS/X RMON Fiber 2 Transceiver/Receiver 512~1023 Octets. |
| 1.3.6.1.4.1.4756.20.300.40.1.311 | Columnf1000EASXFX21024OctetsLocal | read-only | current | FRM220-1000EAS/X RMON Fiber 2 Transceiver/Receiver 1024~Max Octets. |
| 1.3.6.1.4.1.4756.20.300.40.1.312 | Columnf1000EASXUTP3RXOctetsLocal | read-only | current | FRM220-1000EAS/X RMON UTP 3 Receiver Octets. |
| 1.3.6.1.4.1.4756.20.300.40.1.313 | Columnf1000EASXUTP3RXPacketLocal | read-only | current | FRM220-1000EAS/X RMON UTP 3 Receiver Packets. |
| 1.3.6.1.4.1.4756.20.300.40.1.314 | Columnf1000EASXUTP3RXBroadLocal | read-only | current | FRM220-1000EAS/X RMON UTP 3 Receiver Broadcast Packets. |
| 1.3.6.1.4.1.4756.20.300.40.1.315 | Columnf1000EASXUTP3RXMultiLocal | read-only | current | FRM220-1000EAS/X RMON UTP 3 Receiver Multicast Packets. |
| 1.3.6.1.4.1.4756.20.300.40.1.316 | Columnf1000EASXUTP3RXUniLocal | read-only | current | FRM220-1000EAS/X RMON UTP 3 Receiver Unicast Packets. |
| 1.3.6.1.4.1.4756.20.300.40.1.317 | Columnf1000EASXUTP3RXPauseLocal | read-only | current | FRM220-1000EAS/X RMON UTP 3 Receiver Pause Packets. |
| 1.3.6.1.4.1.4756.20.300.40.1.318 | Columnf1000EASXUTP3RXFCSELocal | read-only | current | FRM220-1000EAS/X RMON UTP 3 Receiver FCS Error Packets. |
| 1.3.6.1.4.1.4756.20.300.40.1.319 | Columnf1000EASXUTP3RXUnderLocal | read-only | current | FRM220-1000EAS/X RMON UTP 3 Receiver Under Packets. |
| 1.3.6.1.4.1.4756.20.300.40.1.320 | Columnf1000EASXUTP3RXOverLocal | read-only | current | FRM220-1000EAS/X RMON UTP 3 Receiver Over Packets. |
| 1.3.6.1.4.1.4756.20.300.40.1.321 | Columnf1000EASXUTP3RXJabberLocal | read-only | current | FRM220-1000EAS/X RMON UTP 3 Receiver Jabber Packets. |
| 1.3.6.1.4.1.4756.20.300.40.1.322 | Columnf1000EASXUTP3TXOctetsLocal | read-only | current | FRM220-1000EAS/X RMON UTP 3 Transceiver Octets. |
| 1.3.6.1.4.1.4756.20.300.40.1.323 | Columnf1000EASXUTP3TXPacketLocal | read-only | current | FRM220-1000EAS/X RMON UTP 3 Transceiver Packets. |
| 1.3.6.1.4.1.4756.20.300.40.1.324 | Columnf1000EASXUTP3TXBroadLocal | read-only | current | FRM220-1000EAS/X RMON UTP 3 Transceiver Broadcast Packets. |
| 1.3.6.1.4.1.4756.20.300.40.1.325 | Columnf1000EASXUTP3TXMultiLocal | read-only | current | FRM220-1000EAS/X RMON UTP 3 Transceiver Multicast Packets. |
| 1.3.6.1.4.1.4756.20.300.40.1.326 | Columnf1000EASXUTP3TXUniLocal | read-only | current | FRM220-1000EAS/X RMON UTP 3 Transceiver Unicast Packets. |
| 1.3.6.1.4.1.4756.20.300.40.1.327 | Columnf1000EASXUTP3TXPauseLocal | read-only | current | FRM220-1000EAS/X RMON UTP 3 Transceiver Pause Packets. |
| 1.3.6.1.4.1.4756.20.300.40.1.328 | Columnf1000EASXUTP3TXCollisionLocal | read-only | current | FRM220-1000EAS/X RMON UTP 3 Transceiver Collision Packets. |
| 1.3.6.1.4.1.4756.20.300.40.1.329 | Columnf1000EASXUTP30OctetsLocal | read-only | current | FRM220-1000EAS/X RMON UTP 3 Transceiver/Receiver 0~64 Octets. |
| 1.3.6.1.4.1.4756.20.300.40.1.330 | Columnf1000EASXUTP365OctetsLocal | read-only | current | FRM220-1000EAS/X RMON UTP 3 Transceiver/Receiver 65~127 Octets. |
| 1.3.6.1.4.1.4756.20.300.40.1.331 | Columnf1000EASXUTP3128OctetsLocal | read-only | current | FRM220-1000EAS/X RMON UTP 3 Transceiver/Receiver 128~255 Octets. |
| 1.3.6.1.4.1.4756.20.300.40.1.332 | Columnf1000EASXUTP3256OctetsLocal | read-only | current | FRM220-1000EAS/X RMON UTP 3 Transceiver/Receiver 256~511 Octets. |
| 1.3.6.1.4.1.4756.20.300.40.1.333 | Columnf1000EASXUTP3512OctetsLocal | read-only | current | FRM220-1000EAS/X RMON UTP 3 Transceiver/Receiver 512~1023 Octets. |
| 1.3.6.1.4.1.4756.20.300.40.1.334 | Columnf1000EASXUTP31024OctetsLocal | read-only | current | FRM220-1000EAS/X RMON UTP 3 Transceiver/Receiver 1024~Max Octets. |
| 1.3.6.1.4.1.4756.20.300.40.1.335 | Columnf1000EASXUTP4RXOctetsLocal | read-only | current | FRM220-1000EAS/X RMON UTP 4 Receiver Octets. |
| 1.3.6.1.4.1.4756.20.300.40.1.336 | Columnf1000EASXUTP4RXPacketLocal | read-only | current | FRM220-1000EAS/X RMON UTP 4 Receiver Packets. |
| 1.3.6.1.4.1.4756.20.300.40.1.337 | Columnf1000EASXUTP4RXBroadLocal | read-only | current | FRM220-1000EAS/X RMON UTP 4 Receiver Broadcast Packets. |
| 1.3.6.1.4.1.4756.20.300.40.1.338 | Columnf1000EASXUTP4RXMultiLocal | read-only | current | FRM220-1000EAS/X RMON UTP 4 Receiver Multicast Packets. |
| 1.3.6.1.4.1.4756.20.300.40.1.339 | Columnf1000EASXUTP4RXUniLocal | read-only | current | FRM220-1000EAS/X RMON UTP 4 Receiver Unicast Packets. |
| 1.3.6.1.4.1.4756.20.300.40.1.340 | Columnf1000EASXUTP4RXPauseLocal | read-only | current | FRM220-1000EAS/X RMON UTP 4 Receiver Pause Packets. |
| 1.3.6.1.4.1.4756.20.300.40.1.341 | Columnf1000EASXUTP4RXFCSELocal | read-only | current | FRM220-1000EAS/X RMON UTP 4 Receiver FCS Error Packets. |
| 1.3.6.1.4.1.4756.20.300.40.1.342 | Columnf1000EASXUTP4RXUnderLocal | read-only | current | FRM220-1000EAS/X RMON UTP 4 Receiver Under Packets. |
| 1.3.6.1.4.1.4756.20.300.40.1.343 | Columnf1000EASXUTP4RXOverLocal | read-only | current | FRM220-1000EAS/X RMON UTP 4 Receiver Over Packets. |
| 1.3.6.1.4.1.4756.20.300.40.1.344 | Columnf1000EASXUTP4RXJabberLocal | read-only | current | FRM220-1000EAS/X RMON UTP 4 Receiver Jabber Packets. |
| 1.3.6.1.4.1.4756.20.300.40.1.345 | Columnf1000EASXUTP4TXOctetsLocal | read-only | current | FRM220-1000EAS/X RMON UTP 4 Transceiver Octets. |
| 1.3.6.1.4.1.4756.20.300.40.1.346 | Columnf1000EASXUTP4TXPacketLocal | read-only | current | FRM220-1000EAS/X RMON UTP 4 Transceiver Packets. |
| 1.3.6.1.4.1.4756.20.300.40.1.347 | Columnf1000EASXUTP4TXBroadLocal | read-only | current | FRM220-1000EAS/X RMON UTP 4 Transceiver Broadcast Packets. |
| 1.3.6.1.4.1.4756.20.300.40.1.348 | Columnf1000EASXUTP4TXMultiLocal | read-only | current | FRM220-1000EAS/X RMON UTP 4 Transceiver Multicast Packets. |
| 1.3.6.1.4.1.4756.20.300.40.1.349 | Columnf1000EASXUTP4TXUniLocal | read-only | current | FRM220-1000EAS/X RMON UTP 4 Transceiver Unicast Packets. |
| 1.3.6.1.4.1.4756.20.300.40.1.350 | Columnf1000EASXUTP4TXPauseLocal | read-only | current | FRM220-1000EAS/X RMON UTP 4 Transceiver Pause Packets. |
| 1.3.6.1.4.1.4756.20.300.40.1.351 | Columnf1000EASXUTP4TXCollisionLocal | read-only | current | FRM220-1000EAS/X RMON UTP 4 Transceiver Collision Packets. |
| 1.3.6.1.4.1.4756.20.300.40.1.352 | Columnf1000EASXUTP40OctetsLocal | read-only | current | FRM220-1000EAS/X RMON UTP 4 Transceiver/Receiver 0~64 Octets. |
| 1.3.6.1.4.1.4756.20.300.40.1.353 | Columnf1000EASXUTP465OctetsLocal | read-only | current | FRM220-1000EAS/X RMON UTP 4 Transceiver/Receiver 65~127 Octets. |
| 1.3.6.1.4.1.4756.20.300.40.1.354 | Columnf1000EASXUTP4128OctetsLocal | read-only | current | FRM220-1000EAS/X RMON UTP 4 Transceiver/Receiver 128~255 Octets. |
| 1.3.6.1.4.1.4756.20.300.40.1.355 | Columnf1000EASXUTP4256OctetsLocal | read-only | current | FRM220-1000EAS/X RMON UTP 4 Transceiver/Receiver 256~511 Octets. |
| 1.3.6.1.4.1.4756.20.300.40.1.356 | Columnf1000EASXUTP4512OctetsLocal | read-only | current | FRM220-1000EAS/X RMON UTP 4 Transceiver/Receiver 512~1023 Octets. |
| 1.3.6.1.4.1.4756.20.300.40.1.357 | Columnf1000EASXUTP41024OctetsLocal | read-only | current | FRM220-1000EAS/X RMON UTP 4 Transceiver/Receiver 1024~Max Octets. |
| 1.3.6.1.4.1.4756.20.300.40.1.358 | Columnf1000EASXFiber2ThresholdLocal | read-write | current | Local device Fiber2 Threshold: |
| 1.3.6.1.4.1.4756.20.300.40.1.359 | Columnf1000EASXFiber2SensitivityLocal | read-write | current | Local device Fiber2 Sensitivity: |
| 1.3.6.1.4.1.4756.20.300.40.1.360 | Columnf1000EASXFx1LBTLocal | read-write | current | FRM220-1000EAS/X Fiber 1 LoopBack Test: 0: Disable 1: Enable 2: Not Support |
| 1.3.6.1.4.1.4756.20.300.40.1.361 | Columnf1000EASXFx2LBTLocal | read-write | current | FRM220-1000EAS/X Fiber 2 LoopBack Test: 0: Disable 1: Enable 2: Not Support |
| 1.3.6.1.4.1.4756.20.300.40.1.362 | Columnf1000EASXUtp3LBTLocal | read-write | current | FRM220-1000EAS/X UTP 3 LoopBack Test: 0: Disable 1: Enable 2: Not Support |
| 1.3.6.1.4.1.4756.20.300.40.1.363 | Columnf1000EASXUtp4LBTLocal | read-write | current | FRM220-1000EAS/X UTP 4 LoopBack Test: 0: Disable 1: Enable 2: Not Support |
| 1.3.6.1.4.1.4756.20.301 | Nodef1000EASXRemoteACards | |||
| 1.3.6.1.4.1.4756.20.301.40 | Tablef1000EASXRemoteATable | not-accessible | current | A list of RemoteA 1000EAS/X card entries. |
| 1.3.6.1.4.1.4756.20.301.40.1 | Rowf1000EASXRemoteAEntry | not-accessible | current | An entry containing management information applicable to a particular RemoteA f1000EASX card. |
| 1.3.6.1.4.1.4756.20.301.40.1.1 | Columnf1000EASXChassisIndexRemoteA | read-only | current | A unique value for each chassis ID. For CH20, it is the chassis ID. For CH08, it is always 0. |
| 1.3.6.1.4.1.4756.20.301.40.1.2 | Columnf1000EASXSlotIndexRemoteA | read-only | current | A unique value for each RemoteA card. It is the slot location number. |
| 1.3.6.1.4.1.4756.20.301.40.1.3 | Columnf1000EASXCardHWVerRemoteA | read-only | current | RemoteA device card hardware version x.xxx |
| 1.3.6.1.4.1.4756.20.301.40.1.4 | Columnf1000EASXCardFWVerRemoteA | read-only | current | RemoteA device card firmware version x.xxx |
| 1.3.6.1.4.1.4756.20.301.40.1.5 | Columnf1000EASXCardCPLDVerRemoteA | read-only | current | RemoteA device card CPLD version x.xxx |
| 1.3.6.1.4.1.4756.20.301.40.1.6 | Columnf1000EASXCardFPGAVerRemoteA | read-only | current | RemoteA device card FPGA version x.xxx |
| 1.3.6.1.4.1.4756.20.301.40.1.7 | Columnf1000EASXModelRemoteA | read-only | current | RemoteA 1000EAS/X Serial Type |
| 1.3.6.1.4.1.4756.20.301.40.1.8 | Columnf1000EASXFiber1LinkRemoteA | read-only | current | RemoteA device card fiber port 1 link status: 0:Down 1:Up |
| 1.3.6.1.4.1.4756.20.301.40.1.9 | Columnf1000EASXFiber1OAMLoopedRemoteA | read-only | current | RemoteA device card fiber port 1 OAM looped: 0:Off 1:on |
| 1.3.6.1.4.1.4756.20.301.40.1.10 | Columnf1000EASXFiber1LBTestRemoteA | read-write | current | Force remote device card to do fiber port 1 LoopBack testing: 0:Off 1:Action |
| 1.3.6.1.4.1.4756.20.301.40.1.11 | Columnf1000EASXFiber1OAMRLBStatusRemoteA | read-only | current | Remote device card fiber port 1 LoopBack testing status: 0:Off 1:Ok 2:Fail |
| 1.3.6.1.4.1.4756.20.301.40.1.12 | Columnf1000EASXFiber1RemoPwrAbRemoteA | read-only | current | RemoteA device card fiber port 1 Remote Power status: 0:Abnormal 1:OK 2:None |
| 1.3.6.1.4.1.4756.20.301.40.1.13 | Columnf1000EASXFiber1IngressRateRemoteA | read-write | current | RemoteA device card fiber 1 Ingress Rate Limit: 0 = Unlimit input format: 64k(K),100m(M),100 If doesn't input the unit, the default was Mega. Limite Rate : 64K… |
| 1.3.6.1.4.1.4756.20.301.40.1.14 | Columnf1000EASXFiber1EgressRateRemoteA | read-write | current | RemoteA device card fiber 1 Egress Rate Limit: 0 = Unlimit input format: 64k(K),100m(M),100 If doesn't input the unit, the default was Mega. Limite Rate : 64K … |
| 1.3.6.1.4.1.4756.20.301.40.1.15 | Columnf1000EASXFiber2LinkRemoteA | read-only | current | RemoteA device card fiber port 2 link status: 0:Down 1:Up |
| 1.3.6.1.4.1.4756.20.301.40.1.16 | Columnf1000EASXFiber2OAMLoopedRemoteA | read-only | current | RemoteA device card fiber port 2 OAM looped: 0:Off 1:on |
| 1.3.6.1.4.1.4756.20.301.40.1.17 | Columnf1000EASXFiber2LBTestRemoteA | read-write | current | Force remote device card to do fiber port 2 LoopBack testing: 0:Off 1:Action |
| 1.3.6.1.4.1.4756.20.301.40.1.18 | Columnf1000EASXFiber2OAMRLBStatusRemoteA | read-only | current | Remote device card fiber port 1 LoopBack testing status: 0:Off 1:Ok 2:Fail |
| 1.3.6.1.4.1.4756.20.301.40.1.19 | Columnf1000EASXFiber2RemoPwrAbRemoteA | read-only | current | RemoteA device card fiber port 2 Remote Power status: 0:Abnormal 1:OK 2:None |
| 1.3.6.1.4.1.4756.20.301.40.1.20 | Columnf1000EASXFiber2IngressRateRemoteA | read-write | current | RemoteA device card fiber 2 Ingress Rate Limit: 0 = Unlimit input format: 64k(K),100m(M),100 If doesn't input the unit, the default was Mega. Limite Rate : 64K… |
| 1.3.6.1.4.1.4756.20.301.40.1.21 | Columnf1000EASXFiber2EgressRateRemoteA | read-write | current | RemoteA device card fiber 2 Egress Rate Limit: 0 = Unlimit input format: 64k(K),100m(M),100 If doesn't input the unit, the default was Mega. Limite Rate : 64K … |
| 1.3.6.1.4.1.4756.20.301.40.1.22 | Columnf1000EASXUtp3LinkRemoteA | read-only | current | RemoteA device card UTP port 3 link status: 0:Down 1:Up |
| 1.3.6.1.4.1.4756.20.301.40.1.23 | Columnf1000EASXUtp3NegoRemoteA | read-write | current | RemoteA device card UTP port 3 negotiation status: 0:Manual 1:Auto |
| 1.3.6.1.4.1.4756.20.301.40.1.24 | Columnf1000EASXUtp3SpeedRemoteA | read-write | current | RemoteA device card UTP port 3 speed setting: 0:10 Base-T 1:100 Base-TX 2:1000 Base-TX |
| 1.3.6.1.4.1.4756.20.301.40.1.25 | Columnf1000EASXUtp3DuplexRemoteA | read-write | current | RemoteA device card UTP port 3 duplex setting: 0:Half duplex mode 1:Full duplex mode |
| 1.3.6.1.4.1.4756.20.301.40.1.26 | Columnf1000EASXUtp3SpeedStatusRemoteA | read-only | current | RemoteA device card UTP port 3 speed status: 0:10 Base-T 1:100 Base-TX 2:1000 Base-TX |
| 1.3.6.1.4.1.4756.20.301.40.1.27 | Columnf1000EASXUtp3DuplexStatusRemoteA | read-only | current | RemoteA device card UTP port 3 duplex status: 0:Half duplex mode 1:Full duplex mode |
| 1.3.6.1.4.1.4756.20.301.40.1.28 | Columnf1000EASXUtp3IngressRateRemoteA | read-write | current | RemoteA device card utp 3 Ingress Rate Limit: 0 = Unlimit input format: 64k(K),100m(M),100 If doesn't input the unit, the default was Mega. Limite Rate : 64K ~… |
| 1.3.6.1.4.1.4756.20.301.40.1.29 | Columnf1000EASXUtp3EgressRateRemoteA | read-write | current | RemoteA device card utp 3 Egress Rate Limit: 0 = Unlimit input format: 64k(K),100m(M),100 If doesn't input the unit, the default was Mega. Limite Rate : 64K ~ … |
| 1.3.6.1.4.1.4756.20.301.40.1.30 | Columnf1000EASXUtp4LinkRemoteA | read-only | current | RemoteA device card UTP port 4 link status: 0:Down 1:Up |
| 1.3.6.1.4.1.4756.20.301.40.1.31 | Columnf1000EASXUtp4NegoRemoteA | read-write | current | RemoteA device card UTP port 4 negotiation status: 0:Manual 1:Auto |
| 1.3.6.1.4.1.4756.20.301.40.1.32 | Columnf1000EASXUtp4SpeedRemoteA | read-write | current | RemoteA device card UTP port 4 speed setting: 0:10 Base-T 1:100 Base-TX 2:1000 Base-TX |
| 1.3.6.1.4.1.4756.20.301.40.1.33 | Columnf1000EASXUtp4DuplexRemoteA | read-write | current | RemoteA device card UTP port 4 duplex setting: 0:Half duplex mode 1:Full duplex mode |
| 1.3.6.1.4.1.4756.20.301.40.1.34 | Columnf1000EASXUtp4SpeedStatusRemoteA | read-only | current | RemoteA device card UTP port 4 speed status: 0:10 Base-T 1:100 Base-TX 2:1000 Base-TX |
| 1.3.6.1.4.1.4756.20.301.40.1.35 | Columnf1000EASXUtp4DuplexStatusRemoteA | read-only | current | RemoteA device card UTP port 4 duplex status: 0:Half duplex mode 1:Full duplex mode |
| 1.3.6.1.4.1.4756.20.301.40.1.36 | Columnf1000EASXUtp4IngressRateRemoteA | read-write | current | RemoteA device card utp 4 Ingress Rate Limit: 0 = Unlimit input format: 64k(K),100m(M),100 If doesn't input the unit, the default was Mega. Limite Rate : 64K ~… |
| 1.3.6.1.4.1.4756.20.301.40.1.37 | Columnf1000EASXUtp4EgressRateRemoteA | read-write | current | RemoteA device card utp 4 Egress Rate Limit: 0 = Unlimit input format: 64k(K),100m(M),100 If doesn't input the unit, the default was Mega. Limite Rate : 64K ~ … |
| 1.3.6.1.4.1.4756.20.301.40.1.38 | Columnf1000EASXDeviceResetRemoteA | read-write | current | Force RemoteA device card to reset mode: 0:Off 1:Action |
| 1.3.6.1.4.1.4756.20.301.40.1.39 | Columnf1000EASXUtp3ActiveRemoteA | read-write | current | RemoteA device UTP port 3 active mode: 0:Disable 1:Enable |
| 1.3.6.1.4.1.4756.20.301.40.1.40 | Columnf1000EASXUtp4ActiveRemoteA | read-write | current | RemoteA device UTP port 4 active mode: 0:Disable 1:Enable |
| 1.3.6.1.4.1.4756.20.301.40.1.41 | Columnf1000EASXOamChAModeRemoteA | read-write | current | RemoteA device OAM Channel A mode: 0:Disable 1:passive 2:Active |
| 1.3.6.1.4.1.4756.20.301.40.1.42 | Columnf1000EASXOamChBModeRemoteA | read-write | current | RemoteA device OAM Channel B mode: 0:Disable 1:passive 2:Active |
| 1.3.6.1.4.1.4756.20.301.40.1.43 | Columnf1000EASXOamMaxPDUsRemoteA | read-write | current | RemoteA device OAM max OAMPDU size: 60-1518 Octets |
| 1.3.6.1.4.1.4756.20.301.40.1.44 | Columnf1000EASXFiber1AlsRemoteA | read-write | current | RemoteA device card port 1 Auto Laser Shutdown mode: 0:Disable 1:Enable |
| 1.3.6.1.4.1.4756.20.301.40.1.45 | Columnf1000EASXFiber2AlsRemoteA | read-write | current | RemoteA device card port 2 Auto Laser Shutdown mode: 0:Disable 1:Enable |
| 1.3.6.1.4.1.4756.20.301.40.1.46 | Columnf1000EASXPauseFrameRemoteA | read-write | current | RemoteA device card pause frame mode: 0:Disable 1:Enable |
| 1.3.6.1.4.1.4756.20.301.40.1.47 | Columnf1000EASXFHRModeRemoteA | read-write | current | RemoteA device card FHR Mode: 0:Disable 1:Enable |
| 1.3.6.1.4.1.4756.20.301.40.1.48 | Columnf1000EASXFiber1LLFDepLogiRemoteA | read-write | current | RemoteA device card port 1 Link Loss Forwarding depends boolean logic: 0:and 1:or |
| 1.3.6.1.4.1.4756.20.301.40.1.49 | Columnf1000EASXFiber1LLFDepPort2RemoteA | read-write | current | RemoteA device card port 1 Link Loss Forwarding depends on port 2 Fiber Rx link: 0:don't care 1:selected |
| 1.3.6.1.4.1.4756.20.301.40.1.50 | Columnf1000EASXFiber1LLFDepPort3RemoteA | read-write | current | RemoteA device card port 1 Link Loss Forwarding depends on port 3 Ethernet Rx link: 0:don't care 1:selected |
| 1.3.6.1.4.1.4756.20.301.40.1.51 | Columnf1000EASXFiber1LLFDepPort4RemoteA | read-write | current | RemoteA device card port 1 Link Loss Forwarding depends on port 4 Ethernet Rx link: 0:don't care 1:selected |
| 1.3.6.1.4.1.4756.20.301.40.1.52 | Columnf1000EASXFiber2LLFDepLogiRemoteA | read-write | current | RemoteA device card port 2 Link Loss Forwarding depends boolean logic: 0:and 1:or |
| 1.3.6.1.4.1.4756.20.301.40.1.53 | Columnf1000EASXFiber2LLFDepPort1RemoteA | read-write | current | RemoteA device card port 2 Link Loss Forwarding depends on port 1 Fiber Rx link: 0:don't care 1:selected |
| 1.3.6.1.4.1.4756.20.301.40.1.54 | Columnf1000EASXFiber2LLFDepPort3RemoteA | read-write | current | RemoteA device card port 2 Link Loss Forwarding depends on port 3 Ethernet Rx link: 0:don't care 1:selected |
| 1.3.6.1.4.1.4756.20.301.40.1.55 | Columnf1000EASXFiber2LLFDepPort4RemoteA | read-write | current | RemoteA device card port 2 Link Loss Forwarding depends on port 4 Ethernet Rx link: 0:don't care 1:selected |
| 1.3.6.1.4.1.4756.20.301.40.1.56 | Columnf1000EASXUtp3LLFDepLogiRemoteA | read-write | current | RemoteA device card port 3 Link Loss Forwarding depends boolean logic: 0:and 1:or |
| 1.3.6.1.4.1.4756.20.301.40.1.57 | Columnf1000EASXUtp3LLFDepPort1RemoteA | read-write | current | RemoteA device card port 3 Link Loss Forwarding depends on port 1 Fiber Rx link: 0:don't care 1:selected |
| 1.3.6.1.4.1.4756.20.301.40.1.58 | Columnf1000EASXUtp3LLFDepPort2RemoteA | read-write | current | RemoteA device card port 3 Link Loss Forwarding depends on port 2 Fiber Rx link: 0:don't care 1:selected |
| 1.3.6.1.4.1.4756.20.301.40.1.59 | Columnf1000EASXUtp4LLFDepLogiRemoteA | read-write | current | RemoteA device card port 4 Link Loss Forwarding depends boolean logic: 0:and 1:or |
| 1.3.6.1.4.1.4756.20.301.40.1.60 | Columnf1000EASXUtp4LLFDepPort1RemoteA | read-write | current | RemoteA device card port 4 Link Loss Forwarding depends on port 1 Fiber Rx link: 0:don't care 1:selected |
| 1.3.6.1.4.1.4756.20.301.40.1.61 | Columnf1000EASXUtp4LLFDepPort2RemoteA | read-write | current | RemoteA device card port 4 Link Loss Forwarding depends on port 2 Fiber Rx link: 0:don't care 1:selected |
| 1.3.6.1.4.1.4756.20.301.40.1.62 | Columnf1000EASXAdvanceFunsRemoteA | read-write | current | RemoteA device card Switch functions mode: 0:Normal 1:Port 1 and Port 2 Trunk Bandwidth 2G 2:Port 1 to Port 2 Mirror 4:port 1 and port 2 Redundancy 5:Static 80… |
| 1.3.6.1.4.1.4756.20.301.40.1.63 | Columnf1000EASXFiber1InfoROM1RemoteA | read-only | current | RemoteA device card port 1 INFORemoteOM information 1 valid: 0:Invalid 1:Valid |
| 1.3.6.1.4.1.4756.20.301.40.1.64 | Columnf1000EASXFiber1InfoROM2RemoteA | read-only | current | RemoteA device card port 1 INFORemoteOM information 2 valid: 0:Invalid 1:Valid(replacing D/D function |
| 1.3.6.1.4.1.4756.20.301.40.1.65 | Columnf1000EASXFiber2InfoROM1RemoteA | read-only | current | RemoteA device card port 2 INFORemoteOM information 1 valid: 0:Invalid 1:Valid |
| 1.3.6.1.4.1.4756.20.301.40.1.66 | Columnf1000EASXFiber2InfoROM2RemoteA | read-only | current | RemoteA device card port 2 INFORemoteOM information 2 valid: 0:Invalid 1:Valid(replacing D/D function) |
| 1.3.6.1.4.1.4756.20.301.40.1.67 | Columnf1000EASXFiber1InfoSN1RemoteA | read-only | current | RemoteA device card port 1 INFORemoteOM S/N 1 |
| 1.3.6.1.4.1.4756.20.301.40.1.68 | Columnf1000EASXFiber1InfoSN2RemoteA | read-only | current | RemoteA device card port 1 INFORemoteOM S/N 2 |
| 1.3.6.1.4.1.4756.20.301.40.1.69 | Columnf1000EASXFiber2InfoSN1RemoteA | read-only | current | RemoteA device card port 2 INFORemoteOM S/N 1 |
| 1.3.6.1.4.1.4756.20.301.40.1.70 | Columnf1000EASXFiber2InfoSN2RemoteA | read-only | current | RemoteA device card port 2 INFORemoteOM S/N 2 |
| 1.3.6.1.4.1.4756.20.301.40.1.71 | Columnf1000EASXFiber1DDRemoteA | read-only | current | RemoteA device card fiber port 1 Digital Diagnostic function: 0:No 1:Yes |
| 1.3.6.1.4.1.4756.20.301.40.1.72 | Columnf1000EASXFiber1DDVendorRemoteA | read-only | current | RemoteA device card fiber port 1 D/D information: Vendor name |
| 1.3.6.1.4.1.4756.20.301.40.1.73 | Columnf1000EASXFiber1DDPartNoRemoteA | read-only | current | RemoteA device card fiber port 1 D/D information: Vendor part number |
| 1.3.6.1.4.1.4756.20.301.40.1.74 | Columnf1000EASXFiber1DDVendorSNRemoteA | read-only | current | RemoteA device card fiber port 1 D/D information: Vendor Serial Number |
| 1.3.6.1.4.1.4756.20.301.40.1.75 | Columnf1000EASXFiber1DDFiberTypeRemoteA | read-only | current | RemoteA device card fiber port 1 D/D information: Fiber Type |
| 1.3.6.1.4.1.4756.20.301.40.1.76 | Columnf1000EASXFiber1DDWaveLenRemoteA | read-only | current | RemoteA device card fiber port 1 D/D information: Wave length |
| 1.3.6.1.4.1.4756.20.301.40.1.77 | Columnf1000EASXFiber1DDWaveLen2RemoteA | read-only | current | RemoteA device card fiber port 1 D/D information: Wave length 2 |
| 1.3.6.1.4.1.4756.20.301.40.1.78 | Columnf1000EASXFiber1DDLinkLenRemoteA | read-only | current | RemoteA device card fiber port 1 D/D information: Link length |
| 1.3.6.1.4.1.4756.20.301.40.1.79 | Columnf1000EASXFiber1DDLenUnitRemoteA | read-only | current | RemoteA device card fiber port 1 D/D information: Length Unit |
| 1.3.6.1.4.1.4756.20.301.40.1.80 | Columnf1000EASXFiber1DDStatusRemoteA | read-only | current | RemoteA device card fiber port 1 D/D information: Status Support |
| 1.3.6.1.4.1.4756.20.301.40.1.81 | Columnf1000EASXFiber1DDRxSensRemoteA | read-only | current | RemoteA device card fiber port 1 D/D information: Rx Sensitivity |
| 1.3.6.1.4.1.4756.20.301.40.1.82 | Columnf1000EASXFiber1DDTxPWRRemoteA | read-only | current | RemoteA device card fiber port 1 D/D information: Tx power |
| 1.3.6.1.4.1.4756.20.301.40.1.83 | Columnf1000EASXFiber1DDRxPWRRemoteA | read-only | current | RemoteA device card fiber port 1 D/D information: Rx power |
| 1.3.6.1.4.1.4756.20.301.40.1.84 | Columnf1000EASXFiber1DDTempRemoteA | read-only | current | RemoteA device card fiber port 1 D/D information: Temperature in degree C |
| 1.3.6.1.4.1.4756.20.301.40.1.85 | Columnf1000EASXFiber1DDPWRMarginRemoteA | read-only | current | RemoteA device card fiber port 1 D/D information: Power margin |
| 1.3.6.1.4.1.4756.20.301.40.1.86 | Columnf1000EASXFiber1DDPWRLossRemoteA | read-only | current | RemoteA device card fiber port 1 D/D information: Power loss |
| 1.3.6.1.4.1.4756.20.301.40.1.87 | Columnf1000EASXFiber2DDRemoteA | read-only | current | RemoteA device card fiber port 2 Digital Diagnostic function: 0:No 1:Yes |
| 1.3.6.1.4.1.4756.20.301.40.1.88 | Columnf1000EASXFiber2DDVendorRemoteA | read-only | current | RemoteA device card fiber port 2 D/D information: Vendor name |
| 1.3.6.1.4.1.4756.20.301.40.1.89 | Columnf1000EASXFiber2DDPartNoRemoteA | read-only | current | RemoteA device card fiber port 2 D/D information: Vendor part number |
| 1.3.6.1.4.1.4756.20.301.40.1.90 | Columnf1000EASXFiber2DDVendorSNRemoteA | read-only | current | RemoteA device card fiber port 2 D/D information: Vendor Serial Number |
| 1.3.6.1.4.1.4756.20.301.40.1.91 | Columnf1000EASXFiber2DDFiberTypeRemoteA | read-only | current | RemoteA device card fiber port 2 D/D information: Fiber Type |
| 1.3.6.1.4.1.4756.20.301.40.1.92 | Columnf1000EASXFiber2DDWaveLenRemoteA | read-only | current | RemoteA device card fiber port 2 D/D information: Wave length |
| 1.3.6.1.4.1.4756.20.301.40.1.93 | Columnf1000EASXFiber2DDWaveLen2RemoteA | read-only | current | RemoteA device card fiber port 2 D/D information: Wave length 2 |
| 1.3.6.1.4.1.4756.20.301.40.1.94 | Columnf1000EASXFiber2DDLinkLenRemoteA | read-only | current | RemoteA device card fiber port 2 D/D information: Link length |
| 1.3.6.1.4.1.4756.20.301.40.1.95 | Columnf1000EASXFiber2DDLenUnitRemoteA | read-only | current | RemoteA device card fiber port 2 D/D information: Length Unit |
| 1.3.6.1.4.1.4756.20.301.40.1.96 | Columnf1000EASXFiber2DDStatusRemoteA | read-only | current | RemoteA device card fiber port 2 D/D information: Status Support |
| 1.3.6.1.4.1.4756.20.301.40.1.97 | Columnf1000EASXFiber2DDRxSensRemoteA | read-only | current | RemoteA device card fiber port 2 D/D information: Rx Sensitivity |
| 1.3.6.1.4.1.4756.20.301.40.1.98 | Columnf1000EASXFiber2DDTxPWRRemoteA | read-only | current | RemoteA device card fiber port 2 D/D information: Tx power |
| 1.3.6.1.4.1.4756.20.301.40.1.99 | Columnf1000EASXFiber2DDRxPWRRemoteA | read-only | current | RemoteA device card fiber port 2 D/D information: Rx power |
| 1.3.6.1.4.1.4756.20.301.40.1.100 | Columnf1000EASXFiber2DDTempRemoteA | read-only | current | RemoteA device card fiber port 2 D/D information: Temperature in degree C |
| 1.3.6.1.4.1.4756.20.301.40.1.101 | Columnf1000EASXFiber2DDPWRMarginRemoteA | read-only | current | RemoteA device card fiber port 2 D/D information: Power margin |
| 1.3.6.1.4.1.4756.20.301.40.1.102 | Columnf1000EASXFiber2DDPWRLossRemoteA | read-only | current | RemoteA device card fiber port 2 D/D information: Power loss |
| 1.3.6.1.4.1.4756.20.301.40.1.103 | Columnf1000EASXClrRMONCntsRemoteA | read-write | current | Clear RemoteA device card RMON IN/OUT counters: 0:No action 1:Action |
| 1.3.6.1.4.1.4756.20.301.40.1.104 | Columnf1000EASXFiber1RMONInRemoteA | read-only | current | RemoteA device card port 1 RMON IN counter. |
| 1.3.6.1.4.1.4756.20.301.40.1.105 | Columnf1000EASXFiber1RMONOutRemoteA | read-only | current | RemoteA device card port 1 RMON OUT counter. |
| 1.3.6.1.4.1.4756.20.301.40.1.106 | Columnf1000EASXFiber2RMONInRemoteA | read-only | current | RemoteA device card port 2 RMON IN counter. |
| 1.3.6.1.4.1.4756.20.301.40.1.107 | Columnf1000EASXFiber2RMONOutRemoteA | read-only | current | RemoteA device card port 2 RMON OUT counter. |
| 1.3.6.1.4.1.4756.20.301.40.1.108 | Columnf1000EASXUtp3RMONInRemoteA | read-only | current | RemoteA device card port 3 RMON IN counter. |
| 1.3.6.1.4.1.4756.20.301.40.1.109 | Columnf1000EASXUtp3RMONOutRemoteA | read-only | current | RemoteA device card port 3 RMON OUT counter. |
| 1.3.6.1.4.1.4756.20.301.40.1.110 | Columnf1000EASXUtp4RMONInRemoteA | read-only | current | RemoteA device card port 4 RMON IN counter. |
| 1.3.6.1.4.1.4756.20.301.40.1.111 | Columnf1000EASXUtp4RMONOutRemoteA | read-only | current | RemoteA device card port 4 RMON OUT counter. |
| 1.3.6.1.4.1.4756.20.301.40.1.112 | Columnf1000EASXClrOAMCntsRemoteA | read-write | current | Clear RemoteA device card OAM counters: 0:No action 1:Action |
| 1.3.6.1.4.1.4756.20.301.40.1.113 | Columnf1000EASXIpModeRemoteA | read-write | current | On Rack Ip Mode: 0:Enable 1:Disable |
| 1.3.6.1.4.1.4756.20.301.40.1.114 | Columnf1000EASXOamChATxRemoteA | read-only | current | RemoteA device OAM Channel A TX OAMPDU frame count |
| 1.3.6.1.4.1.4756.20.301.40.1.115 | Columnf1000EASXOamChARxRemoteA | read-only | current | RemoteA device OAM Channel A RX OAMPDU frame count |
| 1.3.6.1.4.1.4756.20.301.40.1.116 | Columnf1000EASXOamInfoChATxRemoteA | read-only | current | RemoteA device OAM Channel A TX Information OAMPDU frame count |
| 1.3.6.1.4.1.4756.20.301.40.1.117 | Columnf1000EASXOamInfoChARxRemoteA | read-only | current | RemoteA device OAM Channel A RX Information OAMPDU frame count |
| 1.3.6.1.4.1.4756.20.301.40.1.118 | Columnf1000EASXOamEventChATxRemoteA | read-only | current | RemoteA device OAM Channel A TX Event OAMPDU frame count |
| 1.3.6.1.4.1.4756.20.301.40.1.119 | Columnf1000EASXOamUniEvtChARxRemoteA | read-only | current | RemoteA device OAM Channel A RX Unique Event OAMPDU frame count |
| 1.3.6.1.4.1.4756.20.301.40.1.120 | Columnf1000EASXOamDupEvtChARxRemoteA | read-only | current | RemoteA device OAM Channel A RX Duplicate Event OAMPDU frame count |
| 1.3.6.1.4.1.4756.20.301.40.1.121 | Columnf1000EASXOamLbChATxRemoteA | read-only | current | RemoteA device OAM Channel A TX Loopback Control OAMPDU frame count |
| 1.3.6.1.4.1.4756.20.301.40.1.122 | Columnf1000EASXOamLbChARxRemoteA | read-only | current | RemoteA device OAM Channel A RX Loopback Control OAMPDU frame count |
| 1.3.6.1.4.1.4756.20.301.40.1.123 | Columnf1000EASXOamVarReqChATxRemoteA | read-only | current | RemoteA device OAM Channel A TX Variable Request OAMPDU frame count |
| 1.3.6.1.4.1.4756.20.301.40.1.124 | Columnf1000EASXOamVarReqChARxRemoteA | read-only | current | RemoteA device OAM Channel A RX Variable Request OAMPDU frame count |
| 1.3.6.1.4.1.4756.20.301.40.1.125 | Columnf1000EASXOamVarRspChATxRemoteA | read-only | current | RemoteA device OAM Channel A TX Variable Response OAMPDU frame count |
| 1.3.6.1.4.1.4756.20.301.40.1.126 | Columnf1000EASXOamVarRspChARxRemoteA | read-only | current | RemoteA device OAM Channel A RX Variable Response OAMPDU frame count |
| 1.3.6.1.4.1.4756.20.301.40.1.127 | Columnf1000EASXOamOuiChATxRemoteA | read-only | current | RemoteA device OAM Channel A TX OUI OAMPDU frame count |
| 1.3.6.1.4.1.4756.20.301.40.1.128 | Columnf1000EASXOamOuiChARxRemoteA | read-only | current | RemoteA device OAM Channel A RX OUI OAMPDU frame count |
| 1.3.6.1.4.1.4756.20.301.40.1.129 | Columnf1000EASXOamUnknowChARxRemoteA | read-only | current | RemoteA device OAM Channel A RX Unsupported OAMPDU frame count |
| 1.3.6.1.4.1.4756.20.301.40.1.130 | Columnf1000EASXOamChBTxRemoteA | read-only | current | RemoteA device OAM Channel B TX OAMPDU frame count |
| 1.3.6.1.4.1.4756.20.301.40.1.131 | Columnf1000EASXOamChBRxRemoteA | read-only | current | RemoteA device OAM Channel B RX OAMPDU frame count |
| 1.3.6.1.4.1.4756.20.301.40.1.132 | Columnf1000EASXOamInfoChBTxRemoteA | read-only | current | RemoteA device OAM Channel B TX Information OAMPDU frame count |
| 1.3.6.1.4.1.4756.20.301.40.1.133 | Columnf1000EASXOamInfoChBRxRemoteA | read-only | current | RemoteA device OAM Channel B RX Information OAMPDU frame count |
| 1.3.6.1.4.1.4756.20.301.40.1.134 | Columnf1000EASXOamEventChBTxRemoteA | read-only | current | RemoteA device OAM Channel B TX Event OAMPDU frame count |
| 1.3.6.1.4.1.4756.20.301.40.1.135 | Columnf1000EASXOamUniEvtChBRxRemoteA | read-only | current | RemoteA device OAM Channel B RX Unique Event OAMPDU frame count |
| 1.3.6.1.4.1.4756.20.301.40.1.136 | Columnf1000EASXOamDupEvtChBRxRemoteA | read-only | current | RemoteA device OAM Channel B RX Duplicate Event OAMPDU frame count |
| 1.3.6.1.4.1.4756.20.301.40.1.137 | Columnf1000EASXOamLbChBTxRemoteA | read-only | current | RemoteA device OAM Channel B TX Loopback Control OAMPDU frame count |
| 1.3.6.1.4.1.4756.20.301.40.1.138 | Columnf1000EASXOamLbChBRxRemoteA | read-only | current | RemoteA device OAM Channel B RX Loopback Control OAMPDU frame count |
| 1.3.6.1.4.1.4756.20.301.40.1.139 | Columnf1000EASXOamVarReqChBTxRemoteA | read-only | current | RemoteA device OAM Channel B TX Variable Request OAMPDU frame count |
| 1.3.6.1.4.1.4756.20.301.40.1.140 | Columnf1000EASXOamVarReqChBRxRemoteA | read-only | current | RemoteA device OAM Channel B RX Variable Request OAMPDU frame count |
| 1.3.6.1.4.1.4756.20.301.40.1.141 | Columnf1000EASXOamVarRspChBTxRemoteA | read-only | current | RemoteA device OAM Channel B TX Variable Response OAMPDU frame count |
| 1.3.6.1.4.1.4756.20.301.40.1.142 | Columnf1000EASXOamVarRspChBRxRemoteA | read-only | current | RemoteA device OAM Channel B RX Variable Response OAMPDU frame count |
| 1.3.6.1.4.1.4756.20.301.40.1.143 | Columnf1000EASXOamOuiChBTxRemoteA | read-only | current | RemoteA device OAM Channel B TX OUI OAMPDU frame count |
| 1.3.6.1.4.1.4756.20.301.40.1.144 | Columnf1000EASXOamOuiChBRxRemoteA | read-only | current | RemoteA device OAM Channel B RX OUI OAMPDU frame count |
| 1.3.6.1.4.1.4756.20.301.40.1.145 | Columnf1000EASXOamUnknowChBRxRemoteA | read-only | current | RemoteA device OAM Channel B RX Unsupported OAMPDU frame count |
| 1.3.6.1.4.1.4756.20.301.40.1.146 | Columnf1000EASXFiber1SpeedRemoteA | read-only | current | RemoteA device Fiber 1 speed : 0:1000Auto 1:1000FDX 2:100FDX |
| 1.3.6.1.4.1.4756.20.301.40.1.147 | Columnf1000EASXFiber2SpeedRemoteA | read-only | current | RemoteA device Fiber 2 speed : 0:1000Auto 1:1000FDX 2:100FDX |
| 1.3.6.1.4.1.4756.20.301.40.1.148 | Columnf1000EASXMacLearningRemoteA | read-write | current | RemoteA device Mac learning : 0:Disable 1:Enable |
| 1.3.6.1.4.1.4756.20.301.40.1.149 | Columnf1000EASXFiber1VLANRemoteA | read-write | current | RemoteA device Fiber 1 VLAN group : 0:Group A 1:Group B |
| 1.3.6.1.4.1.4756.20.301.40.1.150 | Columnf1000EASXFiber2VLANRemoteA | read-write | current | RemoteA device Fiber 2 VLAN group : 0:Group A 1:Group B |
| 1.3.6.1.4.1.4756.20.301.40.1.151 | Columnf1000EASXUtp3VLANRemoteA | read-write | current | RemoteA device UTP 3 VLAN group : 0:Group A 1:Group B |
| 1.3.6.1.4.1.4756.20.301.40.1.152 | Columnf1000EASXUtp4VLANRemoteA | read-write | current | RemoteA device UTP 4 VLAN group : 0:Group A 1:Group B |
| 1.3.6.1.4.1.4756.20.301.40.1.153 | Columnf1000EASXManagementRemoteA | read-write | current | RemoteA device management : 0:Group A 1:Group B 2:Group A+B |
| 1.3.6.1.4.1.4756.20.301.40.1.154 | Columnf1000EASXRedundancyModeRemoteA | read-write | current | RemoteA device redundancy mode : 0:Auto 1:Manual Fiber 1 2:Manual Fiber 2 3:No Reverse 4:Link Budget |
| 1.3.6.1.4.1.4756.20.301.40.1.155 | Columnf1000EASXPortVLANRemoteA | read-write | current | RemoteA device redundancy mode : 0:Disalbe 1:Enable |
| 1.3.6.1.4.1.4756.20.301.40.1.156 | Columnf1000EASXRemoteTLPTRemoteA | read-write | current | RemoteA device redundancy mode : 0:Disalbe 1:Remote A 2:Remote B 3:Remote A&B 4:Remote A/3; Remote B/4 |
| 1.3.6.1.4.1.4756.20.301.40.1.157 | Columnf1000EASXManagementVIDRemoteA | read-write | current | RemoteA device Management VID : |
| 1.3.6.1.4.1.4756.20.301.40.1.158 | Columnf1000EASXThresholdRemoteA | read-write | current | RemoteA device Threshold: |
| 1.3.6.1.4.1.4756.20.301.40.1.159 | Columnf1000EASXSensitivityRemoteA | read-write | current | RemoteA device Sensitivity: |
| 1.3.6.1.4.1.4756.20.301.40.1.160 | Columnf1000EASXTagTypeRemoteA | read-write | current | RemoteA device Tag Type (HEX) : |
| 1.3.6.1.4.1.4756.20.301.40.1.161 | Columnf1000EASXPort1VIDRemoteA | read-write | current | RemoteA device Port 1 VID : |
| 1.3.6.1.4.1.4756.20.301.40.1.162 | Columnf1000EASXPort2VIDRemoteA | read-write | current | RemoteA device Port 2 VID : |
| 1.3.6.1.4.1.4756.20.301.40.1.163 | Columnf1000EASXPort3VIDRemoteA | read-write | current | RemoteA device Port 3 VID : |
| 1.3.6.1.4.1.4756.20.301.40.1.164 | Columnf1000EASXPort4VIDRemoteA | read-write | current | RemoteA device Port 4 VID : |
| 1.3.6.1.4.1.4756.20.301.40.1.165 | Columnf1000EASXPort1QinQRemoteA | read-write | current | RemoteA device Port 1 Q in Q Support : 1:Disable 2:Enable |
| 1.3.6.1.4.1.4756.20.301.40.1.166 | Columnf1000EASXPort2QinQRemoteA | read-write | current | RemoteA device Port 2 Q in Q Support : 1:Disable 2:Enable |
| 1.3.6.1.4.1.4756.20.301.40.1.167 | Columnf1000EASXPort3QinQRemoteA | read-write | current | RemoteA device Port 3 Q in Q Support : 1:Disable 2:Enable |
| 1.3.6.1.4.1.4756.20.301.40.1.168 | Columnf1000EASXPort4QinQRemoteA | read-write | current | RemoteA device Port 4 Q in Q Support : 1:Disable 2:Enable |
| 1.3.6.1.4.1.4756.20.301.40.1.169 | Columnf1000EASXVID1RemoteA | read-write | current | RemoteA device VID 1: |
| 1.3.6.1.4.1.4756.20.301.40.1.170 | Columnf1000EASXVID2RemoteA | read-write | current | RemoteA device VID 2: |
| 1.3.6.1.4.1.4756.20.301.40.1.171 | Columnf1000EASXVID3RemoteA | read-write | current | RemoteA device VID 3: |
| 1.3.6.1.4.1.4756.20.301.40.1.172 | Columnf1000EASXVID4RemoteA | read-write | current | RemoteA device VID 4: |
| 1.3.6.1.4.1.4756.20.301.40.1.173 | Columnf1000EASXVID5RemoteA | read-write | current | RemoteA device VID 5: |
| 1.3.6.1.4.1.4756.20.301.40.1.174 | Columnf1000EASXVID6RemoteA | read-write | current | RemoteA device VID 6: |
| 1.3.6.1.4.1.4756.20.301.40.1.175 | Columnf1000EASXVID7RemoteA | read-write | current | RemoteA device VID 7: |
| 1.3.6.1.4.1.4756.20.301.40.1.176 | Columnf1000EASXVID8RemoteA | read-write | current | RemoteA device VID 8: |
| 1.3.6.1.4.1.4756.20.301.40.1.177 | Columnf1000EASXVID9RemoteA | read-write | current | RemoteA device VID 9: |
| 1.3.6.1.4.1.4756.20.301.40.1.178 | Columnf1000EASXVID10RemoteA | read-write | current | RemoteA device VID 10: |
| 1.3.6.1.4.1.4756.20.301.40.1.179 | Columnf1000EASXVID11RemoteA | read-write | current | RemoteA device VID 11: |
| 1.3.6.1.4.1.4756.20.301.40.1.180 | Columnf1000EASXVID12RemoteA | read-write | current | RemoteA device VID 12: |
| 1.3.6.1.4.1.4756.20.301.40.1.181 | Columnf1000EASXVID13RemoteA | read-write | current | RemoteA device VID 13: |
| 1.3.6.1.4.1.4756.20.301.40.1.182 | Columnf1000EASXVID14RemoteA | read-write | current | RemoteA device VID 14: |
| 1.3.6.1.4.1.4756.20.301.40.1.183 | Columnf1000EASXVID15RemoteA | read-write | current | RemoteA device VID 15: |
| 1.3.6.1.4.1.4756.20.301.40.1.184 | Columnf1000EASXVID16RemoteA | read-write | current | RemoteA device VID 16: |
| 1.3.6.1.4.1.4756.20.301.40.1.185 | Columnf1000EASXPort1Member1RemoteA | read-write | current | RemoteA device card port 1 member: 0:Unmodify 1:Untagged 2:Tagged 3:Nonmember |
| 1.3.6.1.4.1.4756.20.301.40.1.186 | Columnf1000EASXPort1Member2RemoteA | read-write | current | RemoteA device card port 1 member 2: 0:Unmodify 1:Untagged 2:Tagged 3:Nonmember |
| 1.3.6.1.4.1.4756.20.301.40.1.187 | Columnf1000EASXPort1Member3RemoteA | read-write | current | RemoteA device card port 1 member 3: 0:Unmodify 1:Untagged 2:Tagged 3:Nonmember |
| 1.3.6.1.4.1.4756.20.301.40.1.188 | Columnf1000EASXPort1Member4RemoteA | read-write | current | RemoteA device card port 1 member 4: 0:Unmodify 1:Untagged 2:Tagged 3:Nonmember |
| 1.3.6.1.4.1.4756.20.301.40.1.189 | Columnf1000EASXPort1Member5RemoteA | read-write | current | RemoteA device card port 1 member 5: 0:Unmodify 1:Untagged 2:Tagged 3:Nonmember |
| 1.3.6.1.4.1.4756.20.301.40.1.190 | Columnf1000EASXPort1Member6RemoteA | read-write | current | RemoteA device card port 1 member 6: 0:Unmodify 1:Untagged 2:Tagged 3:Nonmember |
| 1.3.6.1.4.1.4756.20.301.40.1.191 | Columnf1000EASXPort1Member7RemoteA | read-write | current | RemoteA device card port 1 member 7: 0:Unmodify 1:Untagged 2:Tagged 3:Nonmember |
| 1.3.6.1.4.1.4756.20.301.40.1.192 | Columnf1000EASXPort1Member8RemoteA | read-write | current | RemoteA device card port 1 member 8: 0:Unmodify 1:Untagged 2:Tagged 3:Nonmember |
| 1.3.6.1.4.1.4756.20.301.40.1.193 | Columnf1000EASXPort1Member9RemoteA | read-write | current | RemoteA device card port 1 member 9: 0:Unmodify 1:Untagged 2:Tagged 3:Nonmember |
| 1.3.6.1.4.1.4756.20.301.40.1.194 | Columnf1000EASXPort1Member10RemoteA | read-write | current | RemoteA device card port 1 member 10: 0:Unmodify 1:Untagged 2:Tagged 3:Nonmember |
| 1.3.6.1.4.1.4756.20.301.40.1.195 | Columnf1000EASXPort1Member11RemoteA | read-write | current | RemoteA device card port 1 member 11: 0:Unmodify 1:Untagged 2:Tagged 3:Nonmember |
| 1.3.6.1.4.1.4756.20.301.40.1.196 | Columnf1000EASXPort1Member12RemoteA | read-write | current | RemoteA device card port 1 member 12: 0:Unmodify 1:Untagged 2:Tagged 3:Nonmember |
| 1.3.6.1.4.1.4756.20.301.40.1.197 | Columnf1000EASXPort1Member13RemoteA | read-write | current | RemoteA device card port 1 member 13: 0:Unmodify 1:Untagged 2:Tagged 3:Nonmember |
| 1.3.6.1.4.1.4756.20.301.40.1.198 | Columnf1000EASXPort1Member14RemoteA | read-write | current | RemoteA device card port 1 member 14: 0:Unmodify 1:Untagged 2:Tagged 3:Nonmember |
| 1.3.6.1.4.1.4756.20.301.40.1.199 | Columnf1000EASXPort1Member15RemoteA | read-write | current | RemoteA device card port 1 member 15: 0:Unmodify 1:Untagged 2:Tagged 3:Nonmember |
| 1.3.6.1.4.1.4756.20.301.40.1.200 | Columnf1000EASXPort1Member16RemoteA | read-write | current | RemoteA device card port 1 member 16: 0:Unmodify 1:Untagged 2:Tagged 3:Nonmember |
| 1.3.6.1.4.1.4756.20.301.40.1.201 | Columnf1000EASXPort2Member1RemoteA | read-write | current | RemoteA device card port 2 member: 0:Unmodify 1:Untagged 2:Tagged 3:Nonmember |
| 1.3.6.1.4.1.4756.20.301.40.1.202 | Columnf1000EASXPort2Member2RemoteA | read-write | current | RemoteA device card port 2 member 2: 0:Unmodify 1:Untagged 2:Tagged 3:Nonmember |
| 1.3.6.1.4.1.4756.20.301.40.1.203 | Columnf1000EASXPort2Member3RemoteA | read-write | current | RemoteA device card port 2 member 3: 0:Unmodify 1:Untagged 2:Tagged 3:Nonmember |
| 1.3.6.1.4.1.4756.20.301.40.1.204 | Columnf1000EASXPort2Member4RemoteA | read-write | current | RemoteA device card port 2 member 4: 0:Unmodify 1:Untagged 2:Tagged 3:Nonmember |
| 1.3.6.1.4.1.4756.20.301.40.1.205 | Columnf1000EASXPort2Member5RemoteA | read-write | current | RemoteA device card port 2 member 5: 0:Unmodify 1:Untagged 2:Tagged 3:Nonmember |
| 1.3.6.1.4.1.4756.20.301.40.1.206 | Columnf1000EASXPort2Member6RemoteA | read-write | current | RemoteA device card port 2 member 6: 0:Unmodify 1:Untagged 2:Tagged 3:Nonmember |
| 1.3.6.1.4.1.4756.20.301.40.1.207 | Columnf1000EASXPort2Member7RemoteA | read-write | current | RemoteA device card port 2 member 7: 0:Unmodify 1:Untagged 2:Tagged 3:Nonmember |
| 1.3.6.1.4.1.4756.20.301.40.1.208 | Columnf1000EASXPort2Member8RemoteA | read-write | current | RemoteA device card port 2 member 8: 0:Unmodify 1:Untagged 2:Tagged 3:Nonmember |
| 1.3.6.1.4.1.4756.20.301.40.1.209 | Columnf1000EASXPort2Member9RemoteA | read-write | current | RemoteA device card port 2 member 9: 0:Unmodify 1:Untagged 2:Tagged 3:Nonmember |
| 1.3.6.1.4.1.4756.20.301.40.1.210 | Columnf1000EASXPort2Member10RemoteA | read-write | current | RemoteA device card port 2 member 10: 0:Unmodify 1:Untagged 2:Tagged 3:Nonmember |
| 1.3.6.1.4.1.4756.20.301.40.1.211 | Columnf1000EASXPort2Member11RemoteA | read-write | current | RemoteA device card port 2 member 11: 0:Unmodify 1:Untagged 2:Tagged 3:Nonmember |
| 1.3.6.1.4.1.4756.20.301.40.1.212 | Columnf1000EASXPort2Member12RemoteA | read-write | current | RemoteA device card port 2 member 12: 0:Unmodify 1:Untagged 2:Tagged 3:Nonmember |
| 1.3.6.1.4.1.4756.20.301.40.1.213 | Columnf1000EASXPort2Member13RemoteA | read-write | current | RemoteA device card port 2 member 13: 0:Unmodify 1:Untagged 2:Tagged 3:Nonmember |
| 1.3.6.1.4.1.4756.20.301.40.1.214 | Columnf1000EASXPort2Member14RemoteA | read-write | current | RemoteA device card port 2 member 14: 0:Unmodify 1:Untagged 2:Tagged 3:Nonmember |
| 1.3.6.1.4.1.4756.20.301.40.1.215 | Columnf1000EASXPort2Member15RemoteA | read-write | current | RemoteA device card port 2 member 15: 0:Unmodify 1:Untagged 2:Tagged 3:Nonmember |
| 1.3.6.1.4.1.4756.20.301.40.1.216 | Columnf1000EASXPort2Member16RemoteA | read-write | current | RemoteA device card port 2 member 16: 0:Unmodify 1:Untagged 2:Tagged 3:Nonmember |
| 1.3.6.1.4.1.4756.20.301.40.1.217 | Columnf1000EASXPort3Member1RemoteA | read-write | current | RemoteA device card port 3 member: 0:Unmodify 1:Untagged 2:Tagged 3:Nonmember |
| 1.3.6.1.4.1.4756.20.301.40.1.218 | Columnf1000EASXPort3Member2RemoteA | read-write | current | RemoteA device card port 3 member 2: 0:Unmodify 1:Untagged 2:Tagged 3:Nonmember |
| 1.3.6.1.4.1.4756.20.301.40.1.219 | Columnf1000EASXPort3Member3RemoteA | read-write | current | RemoteA device card port 3 member 3: 0:Unmodify 1:Untagged 2:Tagged 3:Nonmember |
| 1.3.6.1.4.1.4756.20.301.40.1.220 | Columnf1000EASXPort3Member4RemoteA | read-write | current | RemoteA device card port 3 member 4: 0:Unmodify 1:Untagged 2:Tagged 3:Nonmember |
| 1.3.6.1.4.1.4756.20.301.40.1.221 | Columnf1000EASXPort3Member5RemoteA | read-write | current | RemoteA device card port 3 member 5: 0:Unmodify 1:Untagged 2:Tagged 3:Nonmember |
| 1.3.6.1.4.1.4756.20.301.40.1.222 | Columnf1000EASXPort3Member6RemoteA | read-write | current | RemoteA device card port 3 member 6: 0:Unmodify 1:Untagged 2:Tagged 3:Nonmember |
| 1.3.6.1.4.1.4756.20.301.40.1.223 | Columnf1000EASXPort3Member7RemoteA | read-write | current | RemoteA device card port 3 member 7: 0:Unmodify 1:Untagged 2:Tagged 3:Nonmember |
| 1.3.6.1.4.1.4756.20.301.40.1.224 | Columnf1000EASXPort3Member8RemoteA | read-write | current | RemoteA device card port 3 member 8: 0:Unmodify 1:Untagged 2:Tagged 3:Nonmember |
| 1.3.6.1.4.1.4756.20.301.40.1.225 | Columnf1000EASXPort3Member9RemoteA | read-write | current | RemoteA device card port 3 member 9: 0:Unmodify 1:Untagged 2:Tagged 3:Nonmember |
| 1.3.6.1.4.1.4756.20.301.40.1.226 | Columnf1000EASXPort3Member10RemoteA | read-write | current | RemoteA device card port 3 member 10: 0:Unmodify 1:Untagged 2:Tagged 3:Nonmember |
| 1.3.6.1.4.1.4756.20.301.40.1.227 | Columnf1000EASXPort3Member11RemoteA | read-write | current | RemoteA device card port 3 member 11: 0:Unmodify 1:Untagged 2:Tagged 3:Nonmember |
| 1.3.6.1.4.1.4756.20.301.40.1.228 | Columnf1000EASXPort3Member12RemoteA | read-write | current | RemoteA device card port 3 member 12: 0:Unmodify 1:Untagged 2:Tagged 3:Nonmember |
| 1.3.6.1.4.1.4756.20.301.40.1.229 | Columnf1000EASXPort3Member13RemoteA | read-write | current | RemoteA device card port 3 member 13: 0:Unmodify 1:Untagged 2:Tagged 3:Nonmember |
| 1.3.6.1.4.1.4756.20.301.40.1.230 | Columnf1000EASXPort3Member14RemoteA | read-write | current | RemoteA device card port 3 member 14: 0:Unmodify 1:Untagged 2:Tagged 3:Nonmember |
| 1.3.6.1.4.1.4756.20.301.40.1.231 | Columnf1000EASXPort3Member15RemoteA | read-write | current | RemoteA device card port 3 member 15: 0:Unmodify 1:Untagged 2:Tagged 3:Nonmember |
| 1.3.6.1.4.1.4756.20.301.40.1.232 | Columnf1000EASXPort3Member16RemoteA | read-write | current | RemoteA device card port 3 member 16: 0:Unmodify 1:Untagged 2:Tagged 3:Nonmember |
| 1.3.6.1.4.1.4756.20.301.40.1.233 | Columnf1000EASXPort4Member1RemoteA | read-write | current | RemoteA device card port 4 member: 0:Unmodify 1:Untagged 2:Tagged 3:Nonmember |
| 1.3.6.1.4.1.4756.20.301.40.1.234 | Columnf1000EASXPort4Member2RemoteA | read-write | current | RemoteA device card port 4 member 2: 0:Unmodify 1:Untagged 2:Tagged 3:Nonmember |
| 1.3.6.1.4.1.4756.20.301.40.1.235 | Columnf1000EASXPort4Member3RemoteA | read-write | current | RemoteA device card port 4 member 3: 0:Unmodify 1:Untagged 2:Tagged 3:Nonmember |
| 1.3.6.1.4.1.4756.20.301.40.1.236 | Columnf1000EASXPort4Member4RemoteA | read-write | current | RemoteA device card port 4 member 4: 0:Unmodify 1:Untagged 2:Tagged 3:Nonmember |
| 1.3.6.1.4.1.4756.20.301.40.1.237 | Columnf1000EASXPort4Member5RemoteA | read-write | current | RemoteA device card port 4 member 5: 0:Unmodify 1:Untagged 2:Tagged 3:Nonmember |
| 1.3.6.1.4.1.4756.20.301.40.1.238 | Columnf1000EASXPort4Member6RemoteA | read-write | current | RemoteA device card port 4 member 6: 0:Unmodify 1:Untagged 2:Tagged 3:Nonmember |
| 1.3.6.1.4.1.4756.20.301.40.1.239 | Columnf1000EASXPort4Member7RemoteA | read-write | current | RemoteA device card port 4 member 7: 0:Unmodify 1:Untagged 2:Tagged 3:Nonmember |
| 1.3.6.1.4.1.4756.20.301.40.1.240 | Columnf1000EASXPort4Member8RemoteA | read-write | current | RemoteA device card port 4 member 8: 0:Unmodify 1:Untagged 2:Tagged 3:Nonmember |
| 1.3.6.1.4.1.4756.20.301.40.1.241 | Columnf1000EASXPort4Member9RemoteA | read-write | current | RemoteA device card port 4 member 9: 0:Unmodify 1:Untagged 2:Tagged 3:Nonmember |
| 1.3.6.1.4.1.4756.20.301.40.1.242 | Columnf1000EASXPort4Member10RemoteA | read-write | current | RemoteA device card port 4 member 10: 0:Unmodify 1:Untagged 2:Tagged 3:Nonmember |
| 1.3.6.1.4.1.4756.20.301.40.1.243 | Columnf1000EASXPort4Member11RemoteA | read-write | current | RemoteA device card port 4 member 11: 0:Unmodify 1:Untagged 2:Tagged 3:Nonmember |
| 1.3.6.1.4.1.4756.20.301.40.1.244 | Columnf1000EASXPort4Member12RemoteA | read-write | current | RemoteA device card port 4 member 12: 0:Unmodify 1:Untagged 2:Tagged 3:Nonmember |
| 1.3.6.1.4.1.4756.20.301.40.1.245 | Columnf1000EASXPort4Member13RemoteA | read-write | current | RemoteA device card port 4 member 13: 0:Unmodify 1:Untagged 2:Tagged 3:Nonmember |
| 1.3.6.1.4.1.4756.20.301.40.1.246 | Columnf1000EASXPort4Member14RemoteA | read-write | current | RemoteA device card port 4 member 14: 0:Unmodify 1:Untagged 2:Tagged 3:Nonmember |
| 1.3.6.1.4.1.4756.20.301.40.1.247 | Columnf1000EASXPort4Member15RemoteA | read-write | current | RemoteA device card port 4 member 15: 0:Unmodify 1:Untagged 2:Tagged 3:Nonmember |
| 1.3.6.1.4.1.4756.20.301.40.1.248 | Columnf1000EASXPort4Member16RemoteA | read-write | current | RemoteA device card port 4 member 16: 0:Unmodify 1:Untagged 2:Tagged 3:Nonmember |
| 1.3.6.1.4.1.4756.20.301.40.1.249 | Columnf1000EASXIpAddressRemoteA | read-write | current | RemoteA device IP address |
| 1.3.6.1.4.1.4756.20.301.40.1.250 | Columnf1000EASXNetMaskRemoteA | read-write | current | RemoteA device Netmask |
| 1.3.6.1.4.1.4756.20.301.40.1.251 | Columnf1000EASXGateWayRemoteA | read-write | current | RemoteA device Gateway |
| 1.3.6.1.4.1.4756.20.301.40.1.252 | Columnf1000EASXSetDefaultRemoteA | read-write | current | RemoteA device set to default |
| 1.3.6.1.4.1.4756.20.301.40.1.253 | Columnf1000EASXFx1LinkAlarmRemoteA | read-write | current | RemoteA device fiber 1 link alarm 0:Disable 1:Enable |
| 1.3.6.1.4.1.4756.20.301.40.1.254 | Columnf1000EASXFx2LinkAlarmRemoteA | read-write | current | RemoteA device fiber 2 link alarm 0:Disable 1:Enable |
| 1.3.6.1.4.1.4756.20.301.40.1.255 | Columnf1000EASXUtp3LinkAlarmRemoteA | read-write | current | RemoteA device utp 3 link alarm 0:Disable 1:Enable |
| 1.3.6.1.4.1.4756.20.301.40.1.256 | Columnf1000EASXUtp4LinkAlarmRemoteA | read-write | current | RemoteA device utp 4 link alarm 0:Disable 1:Enable |
| 1.3.6.1.4.1.4756.20.301.40.1.257 | Columnf1000EASXFiber1FEFRemoteA | read-only | current | RemoteA device card fiber1 port FEF status: 0:Off 1:Detected |
| 1.3.6.1.4.1.4756.20.301.40.1.258 | Columnf1000EASXFiber2FEFRemoteA | read-only | current | RemoteA device card fiber2 port FEF status: 0:Off 1:Detected |
| 1.3.6.1.4.1.4756.20.301.40.1.259 | Columnf1000EASXFX1RXOctetsRemoteA | read-only | current | FRM220-1000EAS/X RMON Fiber 1 Receiver Octets. |
| 1.3.6.1.4.1.4756.20.301.40.1.260 | Columnf1000EASXFX1RXPacketRemoteA | read-only | current | FRM220-1000EAS/X RMON Fiber 1 Receiver Packets. |
| 1.3.6.1.4.1.4756.20.301.40.1.261 | Columnf1000EASXFX1RXBroadRemoteA | read-only | current | FRM220-1000EAS/X RMON Fiber 1 Receiver Broadcast Packets. |
| 1.3.6.1.4.1.4756.20.301.40.1.262 | Columnf1000EASXFX1RXMultiRemoteA | read-only | current | FRM220-1000EAS/X RMON Fiber 1 Receiver Multicast Packets. |
| 1.3.6.1.4.1.4756.20.301.40.1.263 | Columnf1000EASXFX1RXUniRemoteA | read-only | current | FRM220-1000EAS/X RMON Fiber 1 Receiver Unicast Packets. |
| 1.3.6.1.4.1.4756.20.301.40.1.264 | Columnf1000EASXFX1RXPauseRemoteA | read-only | current | FRM220-1000EAS/X RMON Fiber 1 Receiver Pause Packets. |
| 1.3.6.1.4.1.4756.20.301.40.1.265 | Columnf1000EASXFX1RXFCSERemoteA | read-only | current | FRM220-1000EAS/X RMON Fiber 1 Receiver FCS Error Packets. |
| 1.3.6.1.4.1.4756.20.301.40.1.266 | Columnf1000EASXFX1RXUnderRemoteA | read-only | current | FRM220-1000EAS/X RMON Fiber 1 Receiver Under Packets. |
| 1.3.6.1.4.1.4756.20.301.40.1.267 | Columnf1000EASXFX1RXOverRemoteA | read-only | current | FRM220-1000EAS/X RMON Fiber 1 Receiver Over Packets. |
| 1.3.6.1.4.1.4756.20.301.40.1.268 | Columnf1000EASXFX1RXJabberRemoteA | read-only | current | FRM220-1000EAS/X RMON Fiber 1 Receiver Jabber Packets. |
| 1.3.6.1.4.1.4756.20.301.40.1.269 | Columnf1000EASXFX1TXOctetsRemoteA | read-only | current | FRM220-1000EAS/X RMON Fiber 1 Transceiver Octets. |
| 1.3.6.1.4.1.4756.20.301.40.1.270 | Columnf1000EASXFX1TXPacketRemoteA | read-only | current | FRM220-1000EAS/X RMON Fiber 1 Transceiver Packets. |
| 1.3.6.1.4.1.4756.20.301.40.1.271 | Columnf1000EASXFX1TXBroadRemoteA | read-only | current | FRM220-1000EAS/X RMON Fiber 1 Transceiver Broadcast Packets. |
| 1.3.6.1.4.1.4756.20.301.40.1.272 | Columnf1000EASXFX1TXMultiRemoteA | read-only | current | FRM220-1000EAS/X RMON Fiber 1 Transceiver Multicast Packets. |
| 1.3.6.1.4.1.4756.20.301.40.1.273 | Columnf1000EASXFX1TXUniRemoteA | read-only | current | FRM220-1000EAS/X RMON Fiber 1 Transceiver Unicast Packets. |
| 1.3.6.1.4.1.4756.20.301.40.1.274 | Columnf1000EASXFX1TXPauseRemoteA | read-only | current | FRM220-1000EAS/X RMON Fiber 1 Transceiver Pause Packets. |
| 1.3.6.1.4.1.4756.20.301.40.1.275 | Columnf1000EASXFX1TXCollisionRemoteA | read-only | current | FRM220-1000EAS/X RMON Fiber 1 Transceiver Collision Packets. |
| 1.3.6.1.4.1.4756.20.301.40.1.276 | Columnf1000EASXFX10OctetsRemoteA | read-only | current | FRM220-1000EAS/X RMON Fiber 1 Transceiver/Receiver 0~64 Octets. |
| 1.3.6.1.4.1.4756.20.301.40.1.277 | Columnf1000EASXFX165OctetsRemoteA | read-only | current | FRM220-1000EAS/X RMON Fiber 1 Transceiver/Receiver 65~127 Octets. |
| 1.3.6.1.4.1.4756.20.301.40.1.278 | Columnf1000EASXFX1128OctetsRemoteA | read-only | current | FRM220-1000EAS/X RMON Fiber 1 Transceiver/Receiver 128~255 Octets. |
| 1.3.6.1.4.1.4756.20.301.40.1.279 | Columnf1000EASXFX1256OctetsRemoteA | read-only | current | FRM220-1000EAS/X RMON Fiber 1 Transceiver/Receiver 256~511 Octets. |
| 1.3.6.1.4.1.4756.20.301.40.1.280 | Columnf1000EASXFX1512OctetsRemoteA | read-only | current | FRM220-1000EAS/X RMON Fiber 1 Transceiver/Receiver 512~1023 Octets. |
| 1.3.6.1.4.1.4756.20.301.40.1.281 | Columnf1000EASXFX11024OctetsRemoteA | read-only | current | FRM220-1000EAS/X RMON Fiber 1 Transceiver/Receiver 1024~Max Octets. |
| 1.3.6.1.4.1.4756.20.301.40.1.282 | Columnf1000EASXFX2RXOctetsRemoteA | read-only | current | FRM220-1000EAS/X RMON Fiber 2 Receiver Octets. |
| 1.3.6.1.4.1.4756.20.301.40.1.283 | Columnf1000EASXFX2RXPacketRemoteA | read-only | current | FRM220-1000EAS/X RMON Fiber 2 Receiver Packets. |
| 1.3.6.1.4.1.4756.20.301.40.1.284 | Columnf1000EASXFX2RXBroadRemoteA | read-only | current | FRM220-1000EAS/X RMON Fiber 2 Receiver Broadcast Packets. |
| 1.3.6.1.4.1.4756.20.301.40.1.285 | Columnf1000EASXFX2RXMultiRemoteA | read-only | current | FRM220-1000EAS/X RMON Fiber 2 Receiver Multicast Packets. |
| 1.3.6.1.4.1.4756.20.301.40.1.286 | Columnf1000EASXFX2RXUniRemoteA | read-only | current | FRM220-1000EAS/X RMON Fiber 2 Receiver Unicast Packets. |
| 1.3.6.1.4.1.4756.20.301.40.1.287 | Columnf1000EASXFX2RXPauseRemoteA | read-only | current | FRM220-1000EAS/X RMON Fiber 2 Receiver Pause Packets. |
| 1.3.6.1.4.1.4756.20.301.40.1.288 | Columnf1000EASXFX2RXFCSERemoteA | read-only | current | FRM220-1000EAS/X RMON Fiber 2 Receiver FCS Error Packets. |
| 1.3.6.1.4.1.4756.20.301.40.1.289 | Columnf1000EASXFX2RXUnderRemoteA | read-only | current | FRM220-1000EAS/X RMON Fiber 2 Receiver Under Packets. |
| 1.3.6.1.4.1.4756.20.301.40.1.290 | Columnf1000EASXFX2RXOverRemoteA | read-only | current | FRM220-1000EAS/X RMON Fiber 2 Receiver Over Packets. |
| 1.3.6.1.4.1.4756.20.301.40.1.291 | Columnf1000EASXFX2RXJabberRemoteA | read-only | current | FRM220-1000EAS/X RMON Fiber 2 Receiver Jabber Packets. |
| 1.3.6.1.4.1.4756.20.301.40.1.292 | Columnf1000EASXFX2TXOctetsRemoteA | read-only | current | FRM220-1000EAS/X RMON Fiber 2 Transceiver Octets. |
| 1.3.6.1.4.1.4756.20.301.40.1.293 | Columnf1000EASXFX2TXPacketRemoteA | read-only | current | FRM220-1000EAS/X RMON Fiber 2 Transceiver Packets. |
| 1.3.6.1.4.1.4756.20.301.40.1.294 | Columnf1000EASXFX2TXBroadRemoteA | read-only | current | FRM220-1000EAS/X RMON Fiber 2 Transceiver Broadcast Packets. |
| 1.3.6.1.4.1.4756.20.301.40.1.295 | Columnf1000EASXFX2TXMultiRemoteA | read-only | current | FRM220-1000EAS/X RMON Fiber 2 Transceiver Multicast Packets. |
| 1.3.6.1.4.1.4756.20.301.40.1.296 | Columnf1000EASXFX2TXUniRemoteA | read-only | current | FRM220-1000EAS/X RMON Fiber 2 Transceiver Unicast Packets. |
| 1.3.6.1.4.1.4756.20.301.40.1.297 | Columnf1000EASXFX2TXPauseRemoteA | read-only | current | FRM220-1000EAS/X RMON Fiber 2 Transceiver Pause Packets. |
| 1.3.6.1.4.1.4756.20.301.40.1.298 | Columnf1000EASXFX2TXCollisionRemoteA | read-only | current | FRM220-1000EAS/X RMON Fiber 2 Transceiver Collision Packets. |
| 1.3.6.1.4.1.4756.20.301.40.1.299 | Columnf1000EASXFX20OctetsRemoteA | read-only | current | FRM220-1000EAS/X RMON Fiber 2 Transceiver/Receiver 0~64 Octets. |
| 1.3.6.1.4.1.4756.20.301.40.1.300 | Columnf1000EASXFX265OctetsRemoteA | read-only | current | FRM220-1000EAS/X RMON Fiber 2 Transceiver/Receiver 65~127 Octets. |
| 1.3.6.1.4.1.4756.20.301.40.1.301 | Columnf1000EASXFX2128OctetsRemoteA | read-only | current | FRM220-1000EAS/X RMON Fiber 2 Transceiver/Receiver 128~255 Octets. |
| 1.3.6.1.4.1.4756.20.301.40.1.302 | Columnf1000EASXFX2256OctetsRemoteA | read-only | current | FRM220-1000EAS/X RMON Fiber 2 Transceiver/Receiver 256~511 Octets. |
| 1.3.6.1.4.1.4756.20.301.40.1.303 | Columnf1000EASXFX2512OctetsRemoteA | read-only | current | FRM220-1000EAS/X RMON Fiber 2 Transceiver/Receiver 512~1023 Octets. |
| 1.3.6.1.4.1.4756.20.301.40.1.304 | Columnf1000EASXFX21024OctetsRemoteA | read-only | current | FRM220-1000EAS/X RMON Fiber 2 Transceiver/Receiver 1024~Max Octets. |
| 1.3.6.1.4.1.4756.20.301.40.1.305 | Columnf1000EASXUTP3RXOctetsRemoteA | read-only | current | FRM220-1000EAS/X RMON UTP 3 Receiver Octets. |
| 1.3.6.1.4.1.4756.20.301.40.1.306 | Columnf1000EASXUTP3RXPacketRemoteA | read-only | current | FRM220-1000EAS/X RMON UTP 3 Receiver Packets. |
| 1.3.6.1.4.1.4756.20.301.40.1.307 | Columnf1000EASXUTP3RXBroadRemoteA | read-only | current | FRM220-1000EAS/X RMON UTP 3 Receiver Broadcast Packets. |
| 1.3.6.1.4.1.4756.20.301.40.1.308 | Columnf1000EASXUTP3RXMultiRemoteA | read-only | current | FRM220-1000EAS/X RMON UTP 3 Receiver Multicast Packets. |
| 1.3.6.1.4.1.4756.20.301.40.1.309 | Columnf1000EASXUTP3RXUniRemoteA | read-only | current | FRM220-1000EAS/X RMON UTP 3 Receiver Unicast Packets. |
| 1.3.6.1.4.1.4756.20.301.40.1.310 | Columnf1000EASXUTP3RXPauseRemoteA | read-only | current | FRM220-1000EAS/X RMON UTP 3 Receiver Pause Packets. |
| 1.3.6.1.4.1.4756.20.301.40.1.311 | Columnf1000EASXUTP3RXFCSERemoteA | read-only | current | FRM220-1000EAS/X RMON UTP 3 Receiver FCS Error Packets. |
| 1.3.6.1.4.1.4756.20.301.40.1.312 | Columnf1000EASXUTP3RXUnderRemoteA | read-only | current | FRM220-1000EAS/X RMON UTP 3 Receiver Under Packets. |
| 1.3.6.1.4.1.4756.20.301.40.1.313 | Columnf1000EASXUTP3RXOverRemoteA | read-only | current | FRM220-1000EAS/X RMON UTP 3 Receiver Over Packets. |
| 1.3.6.1.4.1.4756.20.301.40.1.314 | Columnf1000EASXUTP3RXJabberRemoteA | read-only | current | FRM220-1000EAS/X RMON UTP 3 Receiver Jabber Packets. |
| 1.3.6.1.4.1.4756.20.301.40.1.315 | Columnf1000EASXUTP3TXOctetsRemoteA | read-only | current | FRM220-1000EAS/X RMON UTP 3 Transceiver Octets. |
| 1.3.6.1.4.1.4756.20.301.40.1.316 | Columnf1000EASXUTP3TXPacketRemoteA | read-only | current | FRM220-1000EAS/X RMON UTP 3 Transceiver Packets. |
| 1.3.6.1.4.1.4756.20.301.40.1.317 | Columnf1000EASXUTP3TXBroadRemoteA | read-only | current | FRM220-1000EAS/X RMON UTP 3 Transceiver Broadcast Packets. |
| 1.3.6.1.4.1.4756.20.301.40.1.318 | Columnf1000EASXUTP3TXMultiRemoteA | read-only | current | FRM220-1000EAS/X RMON UTP 3 Transceiver Multicast Packets. |
| 1.3.6.1.4.1.4756.20.301.40.1.319 | Columnf1000EASXUTP3TXUniRemoteA | read-only | current | FRM220-1000EAS/X RMON UTP 3 Transceiver Unicast Packets. |
| 1.3.6.1.4.1.4756.20.301.40.1.320 | Columnf1000EASXUTP3TXPauseRemoteA | read-only | current | FRM220-1000EAS/X RMON UTP 3 Transceiver Pause Packets. |
| 1.3.6.1.4.1.4756.20.301.40.1.321 | Columnf1000EASXUTP3TXCollisionRemoteA | read-only | current | FRM220-1000EAS/X RMON UTP 3 Transceiver Collision Packets. |
| 1.3.6.1.4.1.4756.20.301.40.1.322 | Columnf1000EASXUTP30OctetsRemoteA | read-only | current | FRM220-1000EAS/X RMON UTP 3 Transceiver/Receiver 0~64 Octets. |
| 1.3.6.1.4.1.4756.20.301.40.1.323 | Columnf1000EASXUTP365OctetsRemoteA | read-only | current | FRM220-1000EAS/X RMON UTP 3 Transceiver/Receiver 65~127 Octets. |
| 1.3.6.1.4.1.4756.20.301.40.1.324 | Columnf1000EASXUTP3128OctetsRemoteA | read-only | current | FRM220-1000EAS/X RMON UTP 3 Transceiver/Receiver 128~255 Octets. |
| 1.3.6.1.4.1.4756.20.301.40.1.325 | Columnf1000EASXUTP3256OctetsRemoteA | read-only | current | FRM220-1000EAS/X RMON UTP 3 Transceiver/Receiver 256~511 Octets. |
| 1.3.6.1.4.1.4756.20.301.40.1.326 | Columnf1000EASXUTP3512OctetsRemoteA | read-only | current | FRM220-1000EAS/X RMON UTP 3 Transceiver/Receiver 512~1023 Octets. |
| 1.3.6.1.4.1.4756.20.301.40.1.327 | Columnf1000EASXUTP31024OctetsRemoteA | read-only | current | FRM220-1000EAS/X RMON UTP 3 Transceiver/Receiver 1024~Max Octets. |
| 1.3.6.1.4.1.4756.20.301.40.1.328 | Columnf1000EASXUTP4RXOctetsRemoteA | read-only | current | FRM220-1000EAS/X RMON UTP 4 Receiver Octets. |
| 1.3.6.1.4.1.4756.20.301.40.1.329 | Columnf1000EASXUTP4RXPacketRemoteA | read-only | current | FRM220-1000EAS/X RMON UTP 4 Receiver Packets. |
| 1.3.6.1.4.1.4756.20.301.40.1.330 | Columnf1000EASXUTP4RXBroadRemoteA | read-only | current | FRM220-1000EAS/X RMON UTP 4 Receiver Broadcast Packets. |
| 1.3.6.1.4.1.4756.20.301.40.1.331 | Columnf1000EASXUTP4RXMultiRemoteA | read-only | current | FRM220-1000EAS/X RMON UTP 4 Receiver Multicast Packets. |
| 1.3.6.1.4.1.4756.20.301.40.1.332 | Columnf1000EASXUTP4RXUniRemoteA | read-only | current | FRM220-1000EAS/X RMON UTP 4 Receiver Unicast Packets. |
| 1.3.6.1.4.1.4756.20.301.40.1.333 | Columnf1000EASXUTP4RXPauseRemoteA | read-only | current | FRM220-1000EAS/X RMON UTP 4 Receiver Pause Packets. |
| 1.3.6.1.4.1.4756.20.301.40.1.334 | Columnf1000EASXUTP4RXFCSERemoteA | read-only | current | FRM220-1000EAS/X RMON UTP 4 Receiver FCS Error Packets. |
| 1.3.6.1.4.1.4756.20.301.40.1.335 | Columnf1000EASXUTP4RXUnderRemoteA | read-only | current | FRM220-1000EAS/X RMON UTP 4 Receiver Under Packets. |
| 1.3.6.1.4.1.4756.20.301.40.1.336 | Columnf1000EASXUTP4RXOverRemoteA | read-only | current | FRM220-1000EAS/X RMON UTP 4 Receiver Over Packets. |
| 1.3.6.1.4.1.4756.20.301.40.1.337 | Columnf1000EASXUTP4RXJabberRemoteA | read-only | current | FRM220-1000EAS/X RMON UTP 4 Receiver Jabber Packets. |
| 1.3.6.1.4.1.4756.20.301.40.1.338 | Columnf1000EASXUTP4TXOctetsRemoteA | read-only | current | FRM220-1000EAS/X RMON UTP 4 Transceiver Octets. |
| 1.3.6.1.4.1.4756.20.301.40.1.339 | Columnf1000EASXUTP4TXPacketRemoteA | read-only | current | FRM220-1000EAS/X RMON UTP 4 Transceiver Packets. |
| 1.3.6.1.4.1.4756.20.301.40.1.340 | Columnf1000EASXUTP4TXBroadRemoteA | read-only | current | FRM220-1000EAS/X RMON UTP 4 Transceiver Broadcast Packets. |
| 1.3.6.1.4.1.4756.20.301.40.1.341 | Columnf1000EASXUTP4TXMultiRemoteA | read-only | current | FRM220-1000EAS/X RMON UTP 4 Transceiver Multicast Packets. |
| 1.3.6.1.4.1.4756.20.301.40.1.342 | Columnf1000EASXUTP4TXUniRemoteA | read-only | current | FRM220-1000EAS/X RMON UTP 4 Transceiver Unicast Packets. |
| 1.3.6.1.4.1.4756.20.301.40.1.343 | Columnf1000EASXUTP4TXPauseRemoteA | read-only | current | FRM220-1000EAS/X RMON UTP 4 Transceiver Pause Packets. |
| 1.3.6.1.4.1.4756.20.301.40.1.344 | Columnf1000EASXUTP4TXCollisionRemoteA | read-only | current | FRM220-1000EAS/X RMON UTP 4 Transceiver Collision Packets. |
| 1.3.6.1.4.1.4756.20.301.40.1.345 | Columnf1000EASXUTP40OctetsRemoteA | read-only | current | FRM220-1000EAS/X RMON UTP 4 Transceiver/Receiver 0~64 Octets. |
| 1.3.6.1.4.1.4756.20.301.40.1.346 | Columnf1000EASXUTP465OctetsRemoteA | read-only | current | FRM220-1000EAS/X RMON UTP 4 Transceiver/Receiver 65~127 Octets. |
| 1.3.6.1.4.1.4756.20.301.40.1.347 | Columnf1000EASXUTP4128OctetsRemoteA | read-only | current | FRM220-1000EAS/X RMON UTP 4 Transceiver/Receiver 128~255 Octets. |
| 1.3.6.1.4.1.4756.20.301.40.1.348 | Columnf1000EASXUTP4256OctetsRemoteA | read-only | current | FRM220-1000EAS/X RMON UTP 4 Transceiver/Receiver 256~511 Octets. |
| 1.3.6.1.4.1.4756.20.301.40.1.349 | Columnf1000EASXUTP4512OctetsRemoteA | read-only | current | FRM220-1000EAS/X RMON UTP 4 Transceiver/Receiver 512~1023 Octets. |
| 1.3.6.1.4.1.4756.20.301.40.1.350 | Columnf1000EASXUTP41024OctetsRemoteA | read-only | current | FRM220-1000EAS/X RMON UTP 4 Transceiver/Receiver 1024~Max Octets. |
| 1.3.6.1.4.1.4756.20.302 | Nodef1000EASXRemoteBCards | |||
| 1.3.6.1.4.1.4756.20.302.40 | Tablef1000EASXRemoteBTable | not-accessible | current | A list of RemoteB 1000EAS/X card entries. |
| 1.3.6.1.4.1.4756.20.302.40.1 | Rowf1000EASXRemoteBEntry | not-accessible | current | An entry containing management information applicable to a particular RemoteB f1000EASX card. |
| 1.3.6.1.4.1.4756.20.302.40.1.1 | Columnf1000EASXChassisIndexRemoteB | read-only | current | A unique value for each chassis ID. For CH20, it is the chassis ID. For CH08, it is always 0. |
| 1.3.6.1.4.1.4756.20.302.40.1.2 | Columnf1000EASXSlotIndexRemoteB | read-only | current | A unique value for each RemoteB card. It is the slot location number. |
| 1.3.6.1.4.1.4756.20.302.40.1.3 | Columnf1000EASXCardHWVerRemoteB | read-only | current | RemoteB device card hardware version x.xxx |
| 1.3.6.1.4.1.4756.20.302.40.1.4 | Columnf1000EASXCardFWVerRemoteB | read-only | current | RemoteB device card firmware version x.xxx |
| 1.3.6.1.4.1.4756.20.302.40.1.5 | Columnf1000EASXCardCPLDVerRemoteB | read-only | current | RemoteB device card CPLD version x.xxx |
| 1.3.6.1.4.1.4756.20.302.40.1.6 | Columnf1000EASXCardFPGAVerRemoteB | read-only | current | RemoteB device card FPGA version x.xxx |
| 1.3.6.1.4.1.4756.20.302.40.1.7 | Columnf1000EASXModelRemoteB | read-only | current | RemoteB 1000EAS/X Serial Type |
| 1.3.6.1.4.1.4756.20.302.40.1.8 | Columnf1000EASXFiber1LinkRemoteB | read-only | current | RemoteB device card fiber port 1 link status: 0:Down 1:Up |
| 1.3.6.1.4.1.4756.20.302.40.1.9 | Columnf1000EASXFiber1OAMLoopedRemoteB | read-only | current | RemoteB device card fiber port 1 OAM looped: 0:Off 1:on |
| 1.3.6.1.4.1.4756.20.302.40.1.10 | Columnf1000EASXFiber1LBTestRemoteB | read-write | current | Force remote device card to do fiber port 1 LoopBack testing: 0:Off 1:Action |
| 1.3.6.1.4.1.4756.20.302.40.1.11 | Columnf1000EASXFiber1OAMRLBStatusRemoteB | read-only | current | Remote device card fiber port 1 LoopBack testing status: 0:Off 1:Ok 2:Fail |
| 1.3.6.1.4.1.4756.20.302.40.1.12 | Columnf1000EASXFiber1RemoPwrAbRemoteB | read-only | current | RemoteB device card fiber port 1 Remote Power status: 0:Abnormal 1:OK 2:None |
| 1.3.6.1.4.1.4756.20.302.40.1.13 | Columnf1000EASXFiber1IngressRateRemoteB | read-write | current | RemoteB device card fiber 1 Ingress Rate Limit: 0 = Unlimit input format: 64k(K),100m(M),100 If doesn't input the unit, the default was Mega. Limite Rate : 64K… |
| 1.3.6.1.4.1.4756.20.302.40.1.14 | Columnf1000EASXFiber1EgressRateRemoteB | read-write | current | RemoteB device card fiber 1 Egress Rate Limit: 0 = Unlimit input format: 64k(K),100m(M),100 If doesn't input the unit, the default was Mega. Limite Rate : 64K … |
| 1.3.6.1.4.1.4756.20.302.40.1.15 | Columnf1000EASXFiber2LinkRemoteB | read-only | current | RemoteB device card fiber port 2 link status: 0:Down 1:Up |
| 1.3.6.1.4.1.4756.20.302.40.1.16 | Columnf1000EASXFiber2OAMLoopedRemoteB | read-only | current | RemoteB device card fiber port 2 OAM looped: 0:Off 1:on |
| 1.3.6.1.4.1.4756.20.302.40.1.17 | Columnf1000EASXFiber2LBTestRemoteB | read-write | current | Force remote device card to do fiber port 2 LoopBack testing: 0:Off 1:Action |
| 1.3.6.1.4.1.4756.20.302.40.1.18 | Columnf1000EASXFiber2OAMRLBStatusRemoteB | read-only | current | Remote device card fiber port 1 LoopBack testing status: 0:Off 1:Ok 2:Fail |
| 1.3.6.1.4.1.4756.20.302.40.1.19 | Columnf1000EASXFiber2RemoPwrAbRemoteB | read-only | current | RemoteB device card fiber port 2 Remote Power status: 0:Abnormal 1:OK 2:None |
| 1.3.6.1.4.1.4756.20.302.40.1.20 | Columnf1000EASXFiber2IngressRateRemoteB | read-write | current | RemoteB device card fiber 2 Ingress Rate Limit: 0 = Unlimit input format: 64k(K),100m(M),100 If doesn't input the unit, the default was Mega. Limite Rate : 64K… |
| 1.3.6.1.4.1.4756.20.302.40.1.21 | Columnf1000EASXFiber2EgressRateRemoteB | read-write | current | RemoteB device card fiber 2 Egress Rate Limit: 0 = Unlimit input format: 64k(K),100m(M),100 If doesn't input the unit, the default was Mega. Limite Rate : 64K … |
| 1.3.6.1.4.1.4756.20.302.40.1.22 | Columnf1000EASXUtp3LinkRemoteB | read-only | current | RemoteB device card UTP port 3 link status: 0:Down 1:Up |
| 1.3.6.1.4.1.4756.20.302.40.1.23 | Columnf1000EASXUtp3NegoRemoteB | read-write | current | RemoteB device card UTP port 3 negotiation status: 0:Manual 1:Auto |
| 1.3.6.1.4.1.4756.20.302.40.1.24 | Columnf1000EASXUtp3SpeedRemoteB | read-write | current | RemoteB device card UTP port 3 speed setting: 0:10 Base-T 1:100 Base-TX 2:1000 Base-TX |
| 1.3.6.1.4.1.4756.20.302.40.1.25 | Columnf1000EASXUtp3DuplexRemoteB | read-write | current | RemoteB device card UTP port 3 duplex setting: 0:Half duplex mode 1:Full duplex mode |
| 1.3.6.1.4.1.4756.20.302.40.1.26 | Columnf1000EASXUtp3SpeedStatusRemoteB | read-only | current | RemoteB device card UTP port 3 speed status: 0:10 Base-T 1:100 Base-TX 2:1000 Base-TX |
| 1.3.6.1.4.1.4756.20.302.40.1.27 | Columnf1000EASXUtp3DuplexStatusRemoteB | read-only | current | RemoteB device card UTP port 3 duplex status: 0:Half duplex mode 1:Full duplex mode |
| 1.3.6.1.4.1.4756.20.302.40.1.28 | Columnf1000EASXUtp3IngressRateRemoteB | read-write | current | RemoteB device card utp 3 Ingress Rate Limit: 0 = Unlimit input format: 64k(K),100m(M),100 If doesn't input the unit, the default was Mega. Limite Rate : 64K ~… |
| 1.3.6.1.4.1.4756.20.302.40.1.29 | Columnf1000EASXUtp3EgressRateRemoteB | read-write | current | RemoteB device card utp 3 Egress Rate Limit: 0 = Unlimit input format: 64k(K),100m(M),100 If doesn't input the unit, the default was Mega. Limite Rate : 64K ~ … |
| 1.3.6.1.4.1.4756.20.302.40.1.30 | Columnf1000EASXUtp4LinkRemoteB | read-only | current | RemoteB device card UTP port 4 link status: 0:Down 1:Up |
| 1.3.6.1.4.1.4756.20.302.40.1.31 | Columnf1000EASXUtp4NegoRemoteB | read-write | current | RemoteB device card UTP port 4 negotiation status: 0:Manual 1:Auto |
| 1.3.6.1.4.1.4756.20.302.40.1.32 | Columnf1000EASXUtp4SpeedRemoteB | read-write | current | RemoteB device card UTP port 4 speed setting: 0:10 Base-T 1:100 Base-TX 2:1000 Base-TX |
| 1.3.6.1.4.1.4756.20.302.40.1.33 | Columnf1000EASXUtp4DuplexRemoteB | read-write | current | RemoteB device card UTP port 4 duplex setting: 0:Half duplex mode 1:Full duplex mode |
| 1.3.6.1.4.1.4756.20.302.40.1.34 | Columnf1000EASXUtp4SpeedStatusRemoteB | read-only | current | RemoteB device card UTP port 4 speed status: 0:10 Base-T 1:100 Base-TX 2:1000 Base-TX |
| 1.3.6.1.4.1.4756.20.302.40.1.35 | Columnf1000EASXUtp4DuplexStatusRemoteB | read-only | current | RemoteB device card UTP port 4 duplex status: 0:Half duplex mode 1:Full duplex mode |
| 1.3.6.1.4.1.4756.20.302.40.1.36 | Columnf1000EASXUtp4IngressRateRemoteB | read-write | current | RemoteB device card utp 4 Ingress Rate Limit: 0 = Unlimit input format: 64k(K),100m(M),100 If doesn't input the unit, the default was Mega. Limite Rate : 64K ~… |
| 1.3.6.1.4.1.4756.20.302.40.1.37 | Columnf1000EASXUtp4EgressRateRemoteB | read-write | current | RemoteB device card utp 4 Egress Rate Limit: 0 = Unlimit input format: 64k(K),100m(M),100 If doesn't input the unit, the default was Mega. Limite Rate : 64K ~ … |
| 1.3.6.1.4.1.4756.20.302.40.1.38 | Columnf1000EASXDeviceResetRemoteB | read-write | current | Force RemoteB device card to reset mode: 0:Off 1:Action |
| 1.3.6.1.4.1.4756.20.302.40.1.39 | Columnf1000EASXUtp3ActiveRemoteB | read-write | current | RemoteB device UTP port 3 active mode: 0:Disable 1:Enable |
| 1.3.6.1.4.1.4756.20.302.40.1.40 | Columnf1000EASXUtp4ActiveRemoteB | read-write | current | RemoteB device UTP port 4 active mode: 0:Disable 1:Enable |
| 1.3.6.1.4.1.4756.20.302.40.1.41 | Columnf1000EASXOamChAModeRemoteB | read-write | current | RemoteB device OAM Channel A mode: 0:Disable 1:passive 2:Active |
| 1.3.6.1.4.1.4756.20.302.40.1.42 | Columnf1000EASXOamChBModeRemoteB | read-write | current | RemoteB device OAM Channel B mode: 0:Disable 1:passive 2:Active |
| 1.3.6.1.4.1.4756.20.302.40.1.43 | Columnf1000EASXOamMaxPDUsRemoteB | read-write | current | RemoteB device OAM max OAMPDU size: 60-1518 Octets |
| 1.3.6.1.4.1.4756.20.302.40.1.44 | Columnf1000EASXFiber1AlsRemoteB | read-write | current | RemoteB device card port 1 Auto Laser Shutdown mode: 0:Disable 1:Enable |
| 1.3.6.1.4.1.4756.20.302.40.1.45 | Columnf1000EASXFiber2AlsRemoteB | read-write | current | RemoteB device card port 2 Auto Laser Shutdown mode: 0:Disable 1:Enable |
| 1.3.6.1.4.1.4756.20.302.40.1.46 | Columnf1000EASXPauseFrameRemoteB | read-write | current | RemoteB device card pause frame mode: 0:Disable 1:Enable |
| 1.3.6.1.4.1.4756.20.302.40.1.47 | Columnf1000EASXFHRModeRemoteB | read-write | current | RemoteB device card FHR Mode: 0:Disable 1:Enable |
| 1.3.6.1.4.1.4756.20.302.40.1.48 | Columnf1000EASXFiber1LLFDepLogiRemoteB | read-write | current | RemoteB device card port 1 Link Loss Forwarding depends boolean logic: 0:and 1:or |
| 1.3.6.1.4.1.4756.20.302.40.1.49 | Columnf1000EASXFiber1LLFDepPort2RemoteB | read-write | current | RemoteB device card port 1 Link Loss Forwarding depends on port 2 Fiber Rx link: 0:don't care 1:selected |
| 1.3.6.1.4.1.4756.20.302.40.1.50 | Columnf1000EASXFiber1LLFDepPort3RemoteB | read-write | current | RemoteB device card port 1 Link Loss Forwarding depends on port 3 Ethernet Rx link: 0:don't care 1:selected |
| 1.3.6.1.4.1.4756.20.302.40.1.51 | Columnf1000EASXFiber1LLFDepPort4RemoteB | read-write | current | RemoteB device card port 1 Link Loss Forwarding depends on port 4 Ethernet Rx link: 0:don't care 1:selected |
| 1.3.6.1.4.1.4756.20.302.40.1.52 | Columnf1000EASXFiber2LLFDepLogiRemoteB | read-write | current | RemoteB device card port 2 Link Loss Forwarding depends boolean logic: 0:and 1:or |
| 1.3.6.1.4.1.4756.20.302.40.1.53 | Columnf1000EASXFiber2LLFDepPort1RemoteB | read-write | current | RemoteB device card port 2 Link Loss Forwarding depends on port 1 Fiber Rx link: 0:don't care 1:selected |
| 1.3.6.1.4.1.4756.20.302.40.1.54 | Columnf1000EASXFiber2LLFDepPort3RemoteB | read-write | current | RemoteB device card port 2 Link Loss Forwarding depends on port 3 Ethernet Rx link: 0:don't care 1:selected |
| 1.3.6.1.4.1.4756.20.302.40.1.55 | Columnf1000EASXFiber2LLFDepPort4RemoteB | read-write | current | RemoteB device card port 2 Link Loss Forwarding depends on port 4 Ethernet Rx link: 0:don't care 1:selected |
| 1.3.6.1.4.1.4756.20.302.40.1.56 | Columnf1000EASXUtp3LLFDepLogiRemoteB | read-write | current | RemoteB device card port 3 Link Loss Forwarding depends boolean logic: 0:and 1:or |
| 1.3.6.1.4.1.4756.20.302.40.1.57 | Columnf1000EASXUtp3LLFDepPort1RemoteB | read-write | current | RemoteB device card port 3 Link Loss Forwarding depends on port 1 Fiber Rx link: 0:don't care 1:selected |
| 1.3.6.1.4.1.4756.20.302.40.1.58 | Columnf1000EASXUtp3LLFDepPort2RemoteB | read-write | current | RemoteB device card port 3 Link Loss Forwarding depends on port 2 Fiber Rx link: 0:don't care 1:selected |
| 1.3.6.1.4.1.4756.20.302.40.1.59 | Columnf1000EASXUtp4LLFDepLogiRemoteB | read-write | current | RemoteB device card port 4 Link Loss Forwarding depends boolean logic: 0:and 1:or |
| 1.3.6.1.4.1.4756.20.302.40.1.60 | Columnf1000EASXUtp4LLFDepPort1RemoteB | read-write | current | RemoteB device card port 4 Link Loss Forwarding depends on port 1 Fiber Rx link: 0:don't care 1:selected |
| 1.3.6.1.4.1.4756.20.302.40.1.61 | Columnf1000EASXUtp4LLFDepPort2RemoteB | read-write | current | RemoteB device card port 4 Link Loss Forwarding depends on port 2 Fiber Rx link: 0:don't care 1:selected |
| 1.3.6.1.4.1.4756.20.302.40.1.62 | Columnf1000EASXAdvanceFunsRemoteB | read-write | current | RemoteB device card Switch functions mode: 0:Normal 1:Port 1 and Port 2 Trunk Bandwidth 2G 2:Port 1 to Port 2 Mirror 4:port 1 and port 2 Redundancy 5:Static 80… |
| 1.3.6.1.4.1.4756.20.302.40.1.63 | Columnf1000EASXFiber1InfoROM1RemoteB | read-only | current | RemoteB device card port 1 INFORemoteOM information 1 valid: 0:Invalid 1:Valid |
| 1.3.6.1.4.1.4756.20.302.40.1.64 | Columnf1000EASXFiber1InfoROM2RemoteB | read-only | current | RemoteB device card port 1 INFORemoteOM information 2 valid: 0:Invalid 1:Valid(replacing D/D function |
| 1.3.6.1.4.1.4756.20.302.40.1.65 | Columnf1000EASXFiber2InfoROM1RemoteB | read-only | current | RemoteB device card port 2 INFORemoteOM information 1 valid: 0:Invalid 1:Valid |
| 1.3.6.1.4.1.4756.20.302.40.1.66 | Columnf1000EASXFiber2InfoROM2RemoteB | read-only | current | RemoteB device card port 2 INFORemoteOM information 2 valid: 0:Invalid 1:Valid(replacing D/D function) |
| 1.3.6.1.4.1.4756.20.302.40.1.67 | Columnf1000EASXFiber1InfoSN1RemoteB | read-only | current | RemoteB device card port 1 INFORemoteOM S/N 1 |
| 1.3.6.1.4.1.4756.20.302.40.1.68 | Columnf1000EASXFiber1InfoSN2RemoteB | read-only | current | RemoteB device card port 1 INFORemoteOM S/N 2 |
| 1.3.6.1.4.1.4756.20.302.40.1.69 | Columnf1000EASXFiber2InfoSN1RemoteB | read-only | current | RemoteB device card port 2 INFORemoteOM S/N 1 |
| 1.3.6.1.4.1.4756.20.302.40.1.70 | Columnf1000EASXFiber2InfoSN2RemoteB | read-only | current | RemoteB device card port 2 INFORemoteOM S/N 2 |
| 1.3.6.1.4.1.4756.20.302.40.1.71 | Columnf1000EASXFiber1DDRemoteB | read-only | current | RemoteB device card fiber port 1 Digital Diagnostic function: 0:No 1:Yes |
| 1.3.6.1.4.1.4756.20.302.40.1.72 | Columnf1000EASXFiber1DDVendorRemoteB | read-only | current | RemoteB device card fiber port 1 D/D information: Vendor name |
| 1.3.6.1.4.1.4756.20.302.40.1.73 | Columnf1000EASXFiber1DDPartNoRemoteB | read-only | current | RemoteB device card fiber port 1 D/D information: Vendor part number |
| 1.3.6.1.4.1.4756.20.302.40.1.74 | Columnf1000EASXFiber1DDVendorSNRemoteB | read-only | current | RemoteB device card fiber port 1 D/D information: Vendor Serial Number |
| 1.3.6.1.4.1.4756.20.302.40.1.75 | Columnf1000EASXFiber1DDFiberTypeRemoteB | read-only | current | RemoteB device card fiber port 1 D/D information: Fiber Type |
| 1.3.6.1.4.1.4756.20.302.40.1.76 | Columnf1000EASXFiber1DDWaveLenRemoteB | read-only | current | RemoteB device card fiber port 1 D/D information: Wave length |
| 1.3.6.1.4.1.4756.20.302.40.1.77 | Columnf1000EASXFiber1DDWaveLen2RemoteB | read-only | current | RemoteB device card fiber port 1 D/D information: Wave length 2 |
| 1.3.6.1.4.1.4756.20.302.40.1.78 | Columnf1000EASXFiber1DDLinkLenRemoteB | read-only | current | RemoteB device card fiber port 1 D/D information: Link length |
| 1.3.6.1.4.1.4756.20.302.40.1.79 | Columnf1000EASXFiber1DDLenUnitRemoteB | read-only | current | RemoteB device card fiber port 1 D/D information: Length Unit |
| 1.3.6.1.4.1.4756.20.302.40.1.80 | Columnf1000EASXFiber1DDStatusRemoteB | read-only | current | RemoteB device card fiber port 1 D/D information: Status Support |
| 1.3.6.1.4.1.4756.20.302.40.1.81 | Columnf1000EASXFiber1DDRxSensRemoteB | read-only | current | RemoteB device card fiber port 1 D/D information: Rx Sensitivity |
| 1.3.6.1.4.1.4756.20.302.40.1.82 | Columnf1000EASXFiber1DDTxPWRRemoteB | read-only | current | RemoteB device card fiber port 1 D/D information: Tx power |
| 1.3.6.1.4.1.4756.20.302.40.1.83 | Columnf1000EASXFiber1DDRxPWRRemoteB | read-only | current | RemoteB device card fiber port 1 D/D information: Rx power |
| 1.3.6.1.4.1.4756.20.302.40.1.84 | Columnf1000EASXFiber1DDTempRemoteB | read-only | current | RemoteB device card fiber port 1 D/D information: Temperature in degree C |
| 1.3.6.1.4.1.4756.20.302.40.1.85 | Columnf1000EASXFiber1DDPWRMarginRemoteB | read-only | current | RemoteB device card fiber port 1 D/D information: Power margin |
| 1.3.6.1.4.1.4756.20.302.40.1.86 | Columnf1000EASXFiber1DDPWRLossRemoteB | read-only | current | RemoteB device card fiber port 1 D/D information: Power loss |
| 1.3.6.1.4.1.4756.20.302.40.1.87 | Columnf1000EASXFiber2DDRemoteB | read-only | current | RemoteB device card fiber port 2 Digital Diagnostic function: 0:No 1:Yes |
| 1.3.6.1.4.1.4756.20.302.40.1.88 | Columnf1000EASXFiber2DDVendorRemoteB | read-only | current | RemoteB device card fiber port 2 D/D information: Vendor name |
| 1.3.6.1.4.1.4756.20.302.40.1.89 | Columnf1000EASXFiber2DDPartNoRemoteB | read-only | current | RemoteB device card fiber port 2 D/D information: Vendor part number |
| 1.3.6.1.4.1.4756.20.302.40.1.90 | Columnf1000EASXFiber2DDVendorSNRemoteB | read-only | current | RemoteB device card fiber port 2 D/D information: Vendor Serial Number |
| 1.3.6.1.4.1.4756.20.302.40.1.91 | Columnf1000EASXFiber2DDFiberTypeRemoteB | read-only | current | RemoteB device card fiber port 2 D/D information: Fiber Type |
| 1.3.6.1.4.1.4756.20.302.40.1.92 | Columnf1000EASXFiber2DDWaveLenRemoteB | read-only | current | RemoteB device card fiber port 2 D/D information: Wave length |
| 1.3.6.1.4.1.4756.20.302.40.1.93 | Columnf1000EASXFiber2DDWaveLen2RemoteB | read-only | current | RemoteB device card fiber port 2 D/D information: Wave length 2 |
| 1.3.6.1.4.1.4756.20.302.40.1.94 | Columnf1000EASXFiber2DDLinkLenRemoteB | read-only | current | RemoteB device card fiber port 2 D/D information: Link length |
| 1.3.6.1.4.1.4756.20.302.40.1.95 | Columnf1000EASXFiber2DDLenUnitRemoteB | read-only | current | RemoteB device card fiber port 2 D/D information: Length Unit |
| 1.3.6.1.4.1.4756.20.302.40.1.96 | Columnf1000EASXFiber2DDStatusRemoteB | read-only | current | RemoteB device card fiber port 2 D/D information: Status Support |
| 1.3.6.1.4.1.4756.20.302.40.1.97 | Columnf1000EASXFiber2DDRxSensRemoteB | read-only | current | RemoteB device card fiber port 2 D/D information: Rx Sensitivity |
| 1.3.6.1.4.1.4756.20.302.40.1.98 | Columnf1000EASXFiber2DDTxPWRRemoteB | read-only | current | RemoteB device card fiber port 2 D/D information: Tx power |
| 1.3.6.1.4.1.4756.20.302.40.1.99 | Columnf1000EASXFiber2DDRxPWRRemoteB | read-only | current | RemoteB device card fiber port 2 D/D information: Rx power |
| 1.3.6.1.4.1.4756.20.302.40.1.100 | Columnf1000EASXFiber2DDTempRemoteB | read-only | current | RemoteB device card fiber port 2 D/D information: Temperature in degree C |
| 1.3.6.1.4.1.4756.20.302.40.1.101 | Columnf1000EASXFiber2DDPWRMarginRemoteB | read-only | current | RemoteB device card fiber port 2 D/D information: Power margin |
| 1.3.6.1.4.1.4756.20.302.40.1.102 | Columnf1000EASXFiber2DDPWRLossRemoteB | read-only | current | RemoteB device card fiber port 2 D/D information: Power loss |
| 1.3.6.1.4.1.4756.20.302.40.1.103 | Columnf1000EASXClrRMONCntsRemoteB | read-write | current | Clear RemoteB device card RMON IN/OUT counters: 0:No action 1:Action |
| 1.3.6.1.4.1.4756.20.302.40.1.104 | Columnf1000EASXFiber1RMONInRemoteB | read-only | current | RemoteB device card port 1 RMON IN counter. |
| 1.3.6.1.4.1.4756.20.302.40.1.105 | Columnf1000EASXFiber1RMONOutRemoteB | read-only | current | RemoteB device card port 1 RMON OUT counter. |
| 1.3.6.1.4.1.4756.20.302.40.1.106 | Columnf1000EASXFiber2RMONInRemoteB | read-only | current | RemoteB device card port 2 RMON IN counter. |
| 1.3.6.1.4.1.4756.20.302.40.1.107 | Columnf1000EASXFiber2RMONOutRemoteB | read-only | current | RemoteB device card port 2 RMON OUT counter. |
| 1.3.6.1.4.1.4756.20.302.40.1.108 | Columnf1000EASXUtp3RMONInRemoteB | read-only | current | RemoteB device card port 3 RMON IN counter. |
| 1.3.6.1.4.1.4756.20.302.40.1.109 | Columnf1000EASXUtp3RMONOutRemoteB | read-only | current | RemoteB device card port 3 RMON OUT counter. |
| 1.3.6.1.4.1.4756.20.302.40.1.110 | Columnf1000EASXUtp4RMONInRemoteB | read-only | current | RemoteB device card port 4 RMON IN counter. |
| 1.3.6.1.4.1.4756.20.302.40.1.111 | Columnf1000EASXUtp4RMONOutRemoteB | read-only | current | RemoteB device card port 4 RMON OUT counter. |
| 1.3.6.1.4.1.4756.20.302.40.1.112 | Columnf1000EASXClrOAMCntsRemoteB | read-write | current | Clear RemoteB device card OAM counters: 0:No action 1:Action |
| 1.3.6.1.4.1.4756.20.302.40.1.113 | Columnf1000EASXIpModeRemoteB | read-write | current | On Rack Ip Mode: 0:Enable 1:Disable |
| 1.3.6.1.4.1.4756.20.302.40.1.114 | Columnf1000EASXOamChATxRemoteB | read-only | current | RemoteB device OAM Channel A TX OAMPDU frame count |
| 1.3.6.1.4.1.4756.20.302.40.1.115 | Columnf1000EASXOamChARxRemoteB | read-only | current | RemoteB device OAM Channel A RX OAMPDU frame count |
| 1.3.6.1.4.1.4756.20.302.40.1.116 | Columnf1000EASXOamInfoChATxRemoteB | read-only | current | RemoteB device OAM Channel A TX Information OAMPDU frame count |
| 1.3.6.1.4.1.4756.20.302.40.1.117 | Columnf1000EASXOamInfoChARxRemoteB | read-only | current | RemoteB device OAM Channel A RX Information OAMPDU frame count |
| 1.3.6.1.4.1.4756.20.302.40.1.118 | Columnf1000EASXOamEventChATxRemoteB | read-only | current | RemoteB device OAM Channel A TX Event OAMPDU frame count |
| 1.3.6.1.4.1.4756.20.302.40.1.119 | Columnf1000EASXOamUniEvtChARxRemoteB | read-only | current | RemoteB device OAM Channel A RX Unique Event OAMPDU frame count |
| 1.3.6.1.4.1.4756.20.302.40.1.120 | Columnf1000EASXOamDupEvtChARxRemoteB | read-only | current | RemoteB device OAM Channel A RX Duplicate Event OAMPDU frame count |
| 1.3.6.1.4.1.4756.20.302.40.1.121 | Columnf1000EASXOamLbChATxRemoteB | read-only | current | RemoteB device OAM Channel A TX Loopback Control OAMPDU frame count |
| 1.3.6.1.4.1.4756.20.302.40.1.122 | Columnf1000EASXOamLbChARxRemoteB | read-only | current | RemoteB device OAM Channel A RX Loopback Control OAMPDU frame count |
| 1.3.6.1.4.1.4756.20.302.40.1.123 | Columnf1000EASXOamVarReqChATxRemoteB | read-only | current | RemoteB device OAM Channel A TX Variable Request OAMPDU frame count |
| 1.3.6.1.4.1.4756.20.302.40.1.124 | Columnf1000EASXOamVarReqChARxRemoteB | read-only | current | RemoteB device OAM Channel A RX Variable Request OAMPDU frame count |
| 1.3.6.1.4.1.4756.20.302.40.1.125 | Columnf1000EASXOamVarRspChATxRemoteB | read-only | current | RemoteB device OAM Channel A TX Variable Response OAMPDU frame count |
| 1.3.6.1.4.1.4756.20.302.40.1.126 | Columnf1000EASXOamVarRspChARxRemoteB | read-only | current | RemoteB device OAM Channel A RX Variable Response OAMPDU frame count |
| 1.3.6.1.4.1.4756.20.302.40.1.127 | Columnf1000EASXOamOuiChATxRemoteB | read-only | current | RemoteB device OAM Channel A TX OUI OAMPDU frame count |
| 1.3.6.1.4.1.4756.20.302.40.1.128 | Columnf1000EASXOamOuiChARxRemoteB | read-only | current | RemoteB device OAM Channel A RX OUI OAMPDU frame count |
| 1.3.6.1.4.1.4756.20.302.40.1.129 | Columnf1000EASXOamUnknowChARxRemoteB | read-only | current | RemoteB device OAM Channel A RX Unsupported OAMPDU frame count |
| 1.3.6.1.4.1.4756.20.302.40.1.130 | Columnf1000EASXOamChBTxRemoteB | read-only | current | RemoteB device OAM Channel B TX OAMPDU frame count |
| 1.3.6.1.4.1.4756.20.302.40.1.131 | Columnf1000EASXOamChBRxRemoteB | read-only | current | RemoteB device OAM Channel B RX OAMPDU frame count |
| 1.3.6.1.4.1.4756.20.302.40.1.132 | Columnf1000EASXOamInfoChBTxRemoteB | read-only | current | RemoteB device OAM Channel B TX Information OAMPDU frame count |
| 1.3.6.1.4.1.4756.20.302.40.1.133 | Columnf1000EASXOamInfoChBRxRemoteB | read-only | current | RemoteB device OAM Channel B RX Information OAMPDU frame count |
| 1.3.6.1.4.1.4756.20.302.40.1.134 | Columnf1000EASXOamEventChBTxRemoteB | read-only | current | RemoteB device OAM Channel B TX Event OAMPDU frame count |
| 1.3.6.1.4.1.4756.20.302.40.1.135 | Columnf1000EASXOamUniEvtChBRxRemoteB | read-only | current | RemoteB device OAM Channel B RX Unique Event OAMPDU frame count |
| 1.3.6.1.4.1.4756.20.302.40.1.136 | Columnf1000EASXOamDupEvtChBRxRemoteB | read-only | current | RemoteB device OAM Channel B RX Duplicate Event OAMPDU frame count |
| 1.3.6.1.4.1.4756.20.302.40.1.137 | Columnf1000EASXOamLbChBTxRemoteB | read-only | current | RemoteB device OAM Channel B TX Loopback Control OAMPDU frame count |
| 1.3.6.1.4.1.4756.20.302.40.1.138 | Columnf1000EASXOamLbChBRxRemoteB | read-only | current | RemoteB device OAM Channel B RX Loopback Control OAMPDU frame count |
| 1.3.6.1.4.1.4756.20.302.40.1.139 | Columnf1000EASXOamVarReqChBTxRemoteB | read-only | current | RemoteB device OAM Channel B TX Variable Request OAMPDU frame count |
| 1.3.6.1.4.1.4756.20.302.40.1.140 | Columnf1000EASXOamVarReqChBRxRemoteB | read-only | current | RemoteB device OAM Channel B RX Variable Request OAMPDU frame count |
| 1.3.6.1.4.1.4756.20.302.40.1.141 | Columnf1000EASXOamVarRspChBTxRemoteB | read-only | current | RemoteB device OAM Channel B TX Variable Response OAMPDU frame count |
| 1.3.6.1.4.1.4756.20.302.40.1.142 | Columnf1000EASXOamVarRspChBRxRemoteB | read-only | current | RemoteB device OAM Channel B RX Variable Response OAMPDU frame count |
| 1.3.6.1.4.1.4756.20.302.40.1.143 | Columnf1000EASXOamOuiChBTxRemoteB | read-only | current | RemoteB device OAM Channel B TX OUI OAMPDU frame count |
| 1.3.6.1.4.1.4756.20.302.40.1.144 | Columnf1000EASXOamOuiChBRxRemoteB | read-only | current | RemoteB device OAM Channel B RX OUI OAMPDU frame count |
| 1.3.6.1.4.1.4756.20.302.40.1.145 | Columnf1000EASXOamUnknowChBRxRemoteB | read-only | current | RemoteB device OAM Channel B RX Unsupported OAMPDU frame count |
| 1.3.6.1.4.1.4756.20.302.40.1.146 | Columnf1000EASXFiber1SpeedRemoteB | read-only | current | RemoteB device Fiber 1 speed : 0:1000Auto 1:1000FDX 2:100FDX |
| 1.3.6.1.4.1.4756.20.302.40.1.147 | Columnf1000EASXFiber2SpeedRemoteB | read-only | current | RemoteB device Fiber 2 speed : 0:1000Auto 1:1000FDX 2:100FDX |
| 1.3.6.1.4.1.4756.20.302.40.1.148 | Columnf1000EASXMacLearningRemoteB | read-write | current | RemoteB device Mac learning : 0:Disable 1:Enable |
| 1.3.6.1.4.1.4756.20.302.40.1.149 | Columnf1000EASXFiber1VLANRemoteB | read-write | current | RemoteB device Fiber 1 VLAN group : 0:Group A 1:Group B |
| 1.3.6.1.4.1.4756.20.302.40.1.150 | Columnf1000EASXFiber2VLANRemoteB | read-write | current | RemoteB device Fiber 2 VLAN group : 0:Group A 1:Group B |
| 1.3.6.1.4.1.4756.20.302.40.1.151 | Columnf1000EASXUtp3VLANRemoteB | read-write | current | RemoteB device UTP 3 VLAN group : 0:Group A 1:Group B |
| 1.3.6.1.4.1.4756.20.302.40.1.152 | Columnf1000EASXUtp4VLANRemoteB | read-write | current | RemoteB device UTP 4 VLAN group : 0:Group A 1:Group B |
| 1.3.6.1.4.1.4756.20.302.40.1.153 | Columnf1000EASXManagementRemoteB | read-write | current | RemoteB device management : 0:Group A 1:Group B 2:Group A+B |
| 1.3.6.1.4.1.4756.20.302.40.1.154 | Columnf1000EASXRedundancyModeRemoteB | read-write | current | RemoteB device redundancy mode : 0:Auto 1:Manual Fiber 1 2:Manual Fiber 2 3:No Reverse 4:Link Budget |
| 1.3.6.1.4.1.4756.20.302.40.1.155 | Columnf1000EASXPortVLANRemoteB | read-write | current | RemoteB device redundancy mode : 0:Disalbe 1:Enable |
| 1.3.6.1.4.1.4756.20.302.40.1.156 | Columnf1000EASXRemoteTLPTRemoteB | read-write | current | RemoteB device redundancy mode : 0:Disalbe 1:Remote A 2:Remote B 3:Remote A&B 4:Remote A/3; Remote B/4 |
| 1.3.6.1.4.1.4756.20.302.40.1.157 | Columnf1000EASXManagementVIDRemoteB | read-write | current | RemoteB device Management VID : |
| 1.3.6.1.4.1.4756.20.302.40.1.158 | Columnf1000EASXThresholdRemoteB | read-write | current | RemoteB device Threshold: |
| 1.3.6.1.4.1.4756.20.302.40.1.159 | Columnf1000EASXSensitivityRemoteB | read-write | current | RemoteB device Sensitivity: |
| 1.3.6.1.4.1.4756.20.302.40.1.160 | Columnf1000EASXTagTypeRemoteB | read-write | current | RemoteB device Tag Type (HEX) : |
| 1.3.6.1.4.1.4756.20.302.40.1.161 | Columnf1000EASXPort1VIDRemoteB | read-write | current | RemoteB device Port 1 VID : |
| 1.3.6.1.4.1.4756.20.302.40.1.162 | Columnf1000EASXPort2VIDRemoteB | read-write | current | RemoteB device Port 2 VID : |
| 1.3.6.1.4.1.4756.20.302.40.1.163 | Columnf1000EASXPort3VIDRemoteB | read-write | current | RemoteB device Port 3 VID : |
| 1.3.6.1.4.1.4756.20.302.40.1.164 | Columnf1000EASXPort4VIDRemoteB | read-write | current | RemoteB device Port 4 VID : |
| 1.3.6.1.4.1.4756.20.302.40.1.165 | Columnf1000EASXPort1QinQRemoteB | read-write | current | RemoteB device Port 1 Q in Q Support : 1:Disable 2:Enable |
| 1.3.6.1.4.1.4756.20.302.40.1.166 | Columnf1000EASXPort2QinQRemoteB | read-write | current | RemoteB device Port 2 Q in Q Support : 1:Disable 2:Enable |
| 1.3.6.1.4.1.4756.20.302.40.1.167 | Columnf1000EASXPort3QinQRemoteB | read-write | current | RemoteB device Port 3 Q in Q Support : 1:Disable 2:Enable |
| 1.3.6.1.4.1.4756.20.302.40.1.168 | Columnf1000EASXPort4QinQRemoteB | read-write | current | RemoteB device Port 4 Q in Q Support : 1:Disable 2:Enable |
| 1.3.6.1.4.1.4756.20.302.40.1.169 | Columnf1000EASXVID1RemoteB | read-write | current | RemoteB device VID 1: |
| 1.3.6.1.4.1.4756.20.302.40.1.170 | Columnf1000EASXVID2RemoteB | read-write | current | RemoteB device VID 2: |
| 1.3.6.1.4.1.4756.20.302.40.1.171 | Columnf1000EASXVID3RemoteB | read-write | current | RemoteB device VID 3: |
| 1.3.6.1.4.1.4756.20.302.40.1.172 | Columnf1000EASXVID4RemoteB | read-write | current | RemoteB device VID 4: |
| 1.3.6.1.4.1.4756.20.302.40.1.173 | Columnf1000EASXVID5RemoteB | read-write | current | RemoteB device VID 5: |
| 1.3.6.1.4.1.4756.20.302.40.1.174 | Columnf1000EASXVID6RemoteB | read-write | current | RemoteB device VID 6: |
| 1.3.6.1.4.1.4756.20.302.40.1.175 | Columnf1000EASXVID7RemoteB | read-write | current | RemoteB device VID 7: |
| 1.3.6.1.4.1.4756.20.302.40.1.176 | Columnf1000EASXVID8RemoteB | read-write | current | RemoteB device VID 8: |
| 1.3.6.1.4.1.4756.20.302.40.1.177 | Columnf1000EASXVID9RemoteB | read-write | current | RemoteB device VID 9: |
| 1.3.6.1.4.1.4756.20.302.40.1.178 | Columnf1000EASXVID10RemoteB | read-write | current | RemoteB device VID 10: |
| 1.3.6.1.4.1.4756.20.302.40.1.179 | Columnf1000EASXVID11RemoteB | read-write | current | RemoteB device VID 11: |
| 1.3.6.1.4.1.4756.20.302.40.1.180 | Columnf1000EASXVID12RemoteB | read-write | current | RemoteB device VID 12: |
| 1.3.6.1.4.1.4756.20.302.40.1.181 | Columnf1000EASXVID13RemoteB | read-write | current | RemoteB device VID 13: |
| 1.3.6.1.4.1.4756.20.302.40.1.182 | Columnf1000EASXVID14RemoteB | read-write | current | RemoteB device VID 14: |
| 1.3.6.1.4.1.4756.20.302.40.1.183 | Columnf1000EASXVID15RemoteB | read-write | current | RemoteB device VID 15: |
| 1.3.6.1.4.1.4756.20.302.40.1.184 | Columnf1000EASXVID16RemoteB | read-write | current | RemoteB device VID 16: |
| 1.3.6.1.4.1.4756.20.302.40.1.185 | Columnf1000EASXPort1Member1RemoteB | read-write | current | RemoteB device card port 1 member: 0:Unmodify 1:Untagged 2:Tagged 3:Nonmember |
| 1.3.6.1.4.1.4756.20.302.40.1.186 | Columnf1000EASXPort1Member2RemoteB | read-write | current | RemoteB device card port 1 member 2: 0:Unmodify 1:Untagged 2:Tagged 3:Nonmember |
| 1.3.6.1.4.1.4756.20.302.40.1.187 | Columnf1000EASXPort1Member3RemoteB | read-write | current | RemoteB device card port 1 member 3: 0:Unmodify 1:Untagged 2:Tagged 3:Nonmember |
| 1.3.6.1.4.1.4756.20.302.40.1.188 | Columnf1000EASXPort1Member4RemoteB | read-write | current | RemoteB device card port 1 member 4: 0:Unmodify 1:Untagged 2:Tagged 3:Nonmember |
| 1.3.6.1.4.1.4756.20.302.40.1.189 | Columnf1000EASXPort1Member5RemoteB | read-write | current | RemoteB device card port 1 member 5: 0:Unmodify 1:Untagged 2:Tagged 3:Nonmember |
| 1.3.6.1.4.1.4756.20.302.40.1.190 | Columnf1000EASXPort1Member6RemoteB | read-write | current | RemoteB device card port 1 member 6: 0:Unmodify 1:Untagged 2:Tagged 3:Nonmember |
| 1.3.6.1.4.1.4756.20.302.40.1.191 | Columnf1000EASXPort1Member7RemoteB | read-write | current | RemoteB device card port 1 member 7: 0:Unmodify 1:Untagged 2:Tagged 3:Nonmember |
| 1.3.6.1.4.1.4756.20.302.40.1.192 | Columnf1000EASXPort1Member8RemoteB | read-write | current | RemoteB device card port 1 member 8: 0:Unmodify 1:Untagged 2:Tagged 3:Nonmember |
| 1.3.6.1.4.1.4756.20.302.40.1.193 | Columnf1000EASXPort1Member9RemoteB | read-write | current | RemoteB device card port 1 member 9: 0:Unmodify 1:Untagged 2:Tagged 3:Nonmember |
| 1.3.6.1.4.1.4756.20.302.40.1.194 | Columnf1000EASXPort1Member10RemoteB | read-write | current | RemoteB device card port 1 member 10: 0:Unmodify 1:Untagged 2:Tagged 3:Nonmember |
| 1.3.6.1.4.1.4756.20.302.40.1.195 | Columnf1000EASXPort1Member11RemoteB | read-write | current | RemoteB device card port 1 member 11: 0:Unmodify 1:Untagged 2:Tagged 3:Nonmember |
| 1.3.6.1.4.1.4756.20.302.40.1.196 | Columnf1000EASXPort1Member12RemoteB | read-write | current | RemoteB device card port 1 member 12: 0:Unmodify 1:Untagged 2:Tagged 3:Nonmember |
| 1.3.6.1.4.1.4756.20.302.40.1.197 | Columnf1000EASXPort1Member13RemoteB | read-write | current | RemoteB device card port 1 member 13: 0:Unmodify 1:Untagged 2:Tagged 3:Nonmember |
| 1.3.6.1.4.1.4756.20.302.40.1.198 | Columnf1000EASXPort1Member14RemoteB | read-write | current | RemoteB device card port 1 member 14: 0:Unmodify 1:Untagged 2:Tagged 3:Nonmember |
| 1.3.6.1.4.1.4756.20.302.40.1.199 | Columnf1000EASXPort1Member15RemoteB | read-write | current | RemoteB device card port 1 member 15: 0:Unmodify 1:Untagged 2:Tagged 3:Nonmember |
| 1.3.6.1.4.1.4756.20.302.40.1.200 | Columnf1000EASXPort1Member16RemoteB | read-write | current | RemoteB device card port 1 member 16: 0:Unmodify 1:Untagged 2:Tagged 3:Nonmember |
| 1.3.6.1.4.1.4756.20.302.40.1.201 | Columnf1000EASXPort2Member1RemoteB | read-write | current | RemoteB device card port 2 member: 0:Unmodify 1:Untagged 2:Tagged 3:Nonmember |
| 1.3.6.1.4.1.4756.20.302.40.1.202 | Columnf1000EASXPort2Member2RemoteB | read-write | current | RemoteB device card port 2 member 2: 0:Unmodify 1:Untagged 2:Tagged 3:Nonmember |
| 1.3.6.1.4.1.4756.20.302.40.1.203 | Columnf1000EASXPort2Member3RemoteB | read-write | current | RemoteB device card port 2 member 3: 0:Unmodify 1:Untagged 2:Tagged 3:Nonmember |
| 1.3.6.1.4.1.4756.20.302.40.1.204 | Columnf1000EASXPort2Member4RemoteB | read-write | current | RemoteB device card port 2 member 4: 0:Unmodify 1:Untagged 2:Tagged 3:Nonmember |
| 1.3.6.1.4.1.4756.20.302.40.1.205 | Columnf1000EASXPort2Member5RemoteB | read-write | current | RemoteB device card port 2 member 5: 0:Unmodify 1:Untagged 2:Tagged 3:Nonmember |
| 1.3.6.1.4.1.4756.20.302.40.1.206 | Columnf1000EASXPort2Member6RemoteB | read-write | current | RemoteB device card port 2 member 6: 0:Unmodify 1:Untagged 2:Tagged 3:Nonmember |
| 1.3.6.1.4.1.4756.20.302.40.1.207 | Columnf1000EASXPort2Member7RemoteB | read-write | current | RemoteB device card port 2 member 7: 0:Unmodify 1:Untagged 2:Tagged 3:Nonmember |
| 1.3.6.1.4.1.4756.20.302.40.1.208 | Columnf1000EASXPort2Member8RemoteB | read-write | current | RemoteB device card port 2 member 8: 0:Unmodify 1:Untagged 2:Tagged 3:Nonmember |
| 1.3.6.1.4.1.4756.20.302.40.1.209 | Columnf1000EASXPort2Member9RemoteB | read-write | current | RemoteB device card port 2 member 9: 0:Unmodify 1:Untagged 2:Tagged 3:Nonmember |
| 1.3.6.1.4.1.4756.20.302.40.1.210 | Columnf1000EASXPort2Member10RemoteB | read-write | current | RemoteB device card port 2 member 10: 0:Unmodify 1:Untagged 2:Tagged 3:Nonmember |
| 1.3.6.1.4.1.4756.20.302.40.1.211 | Columnf1000EASXPort2Member11RemoteB | read-write | current | RemoteB device card port 2 member 11: 0:Unmodify 1:Untagged 2:Tagged 3:Nonmember |
| 1.3.6.1.4.1.4756.20.302.40.1.212 | Columnf1000EASXPort2Member12RemoteB | read-write | current | RemoteB device card port 2 member 12: 0:Unmodify 1:Untagged 2:Tagged 3:Nonmember |
| 1.3.6.1.4.1.4756.20.302.40.1.213 | Columnf1000EASXPort2Member13RemoteB | read-write | current | RemoteB device card port 2 member 13: 0:Unmodify 1:Untagged 2:Tagged 3:Nonmember |
| 1.3.6.1.4.1.4756.20.302.40.1.214 | Columnf1000EASXPort2Member14RemoteB | read-write | current | RemoteB device card port 2 member 14: 0:Unmodify 1:Untagged 2:Tagged 3:Nonmember |
| 1.3.6.1.4.1.4756.20.302.40.1.215 | Columnf1000EASXPort2Member15RemoteB | read-write | current | RemoteB device card port 2 member 15: 0:Unmodify 1:Untagged 2:Tagged 3:Nonmember |
| 1.3.6.1.4.1.4756.20.302.40.1.216 | Columnf1000EASXPort2Member16RemoteB | read-write | current | RemoteB device card port 2 member 16: 0:Unmodify 1:Untagged 2:Tagged 3:Nonmember |
| 1.3.6.1.4.1.4756.20.302.40.1.217 | Columnf1000EASXPort3Member1RemoteB | read-write | current | RemoteB device card port 3 member: 0:Unmodify 1:Untagged 2:Tagged 3:Nonmember |
| 1.3.6.1.4.1.4756.20.302.40.1.218 | Columnf1000EASXPort3Member2RemoteB | read-write | current | RemoteB device card port 3 member 2: 0:Unmodify 1:Untagged 2:Tagged 3:Nonmember |
| 1.3.6.1.4.1.4756.20.302.40.1.219 | Columnf1000EASXPort3Member3RemoteB | read-write | current | RemoteB device card port 3 member 3: 0:Unmodify 1:Untagged 2:Tagged 3:Nonmember |
| 1.3.6.1.4.1.4756.20.302.40.1.220 | Columnf1000EASXPort3Member4RemoteB | read-write | current | RemoteB device card port 3 member 4: 0:Unmodify 1:Untagged 2:Tagged 3:Nonmember |
| 1.3.6.1.4.1.4756.20.302.40.1.221 | Columnf1000EASXPort3Member5RemoteB | read-write | current | RemoteB device card port 3 member 5: 0:Unmodify 1:Untagged 2:Tagged 3:Nonmember |
| 1.3.6.1.4.1.4756.20.302.40.1.222 | Columnf1000EASXPort3Member6RemoteB | read-write | current | RemoteB device card port 3 member 6: 0:Unmodify 1:Untagged 2:Tagged 3:Nonmember |
| 1.3.6.1.4.1.4756.20.302.40.1.223 | Columnf1000EASXPort3Member7RemoteB | read-write | current | RemoteB device card port 3 member 7: 0:Unmodify 1:Untagged 2:Tagged 3:Nonmember |
| 1.3.6.1.4.1.4756.20.302.40.1.224 | Columnf1000EASXPort3Member8RemoteB | read-write | current | RemoteB device card port 3 member 8: 0:Unmodify 1:Untagged 2:Tagged 3:Nonmember |
| 1.3.6.1.4.1.4756.20.302.40.1.225 | Columnf1000EASXPort3Member9RemoteB | read-write | current | RemoteB device card port 3 member 9: 0:Unmodify 1:Untagged 2:Tagged 3:Nonmember |
| 1.3.6.1.4.1.4756.20.302.40.1.226 | Columnf1000EASXPort3Member10RemoteB | read-write | current | RemoteB device card port 3 member 10: 0:Unmodify 1:Untagged 2:Tagged 3:Nonmember |
| 1.3.6.1.4.1.4756.20.302.40.1.227 | Columnf1000EASXPort3Member11RemoteB | read-write | current | RemoteB device card port 3 member 11: 0:Unmodify 1:Untagged 2:Tagged 3:Nonmember |
| 1.3.6.1.4.1.4756.20.302.40.1.228 | Columnf1000EASXPort3Member12RemoteB | read-write | current | RemoteB device card port 3 member 12: 0:Unmodify 1:Untagged 2:Tagged 3:Nonmember |
| 1.3.6.1.4.1.4756.20.302.40.1.229 | Columnf1000EASXPort3Member13RemoteB | read-write | current | RemoteB device card port 3 member 13: 0:Unmodify 1:Untagged 2:Tagged 3:Nonmember |
| 1.3.6.1.4.1.4756.20.302.40.1.230 | Columnf1000EASXPort3Member14RemoteB | read-write | current | RemoteB device card port 3 member 14: 0:Unmodify 1:Untagged 2:Tagged 3:Nonmember |
| 1.3.6.1.4.1.4756.20.302.40.1.231 | Columnf1000EASXPort3Member15RemoteB | read-write | current | RemoteB device card port 3 member 15: 0:Unmodify 1:Untagged 2:Tagged 3:Nonmember |
| 1.3.6.1.4.1.4756.20.302.40.1.232 | Columnf1000EASXPort3Member16RemoteB | read-write | current | RemoteB device card port 3 member 16: 0:Unmodify 1:Untagged 2:Tagged 3:Nonmember |
| 1.3.6.1.4.1.4756.20.302.40.1.233 | Columnf1000EASXPort4Member1RemoteB | read-write | current | RemoteB device card port 4 member: 0:Unmodify 1:Untagged 2:Tagged 3:Nonmember |
| 1.3.6.1.4.1.4756.20.302.40.1.234 | Columnf1000EASXPort4Member2RemoteB | read-write | current | RemoteB device card port 4 member 2: 0:Unmodify 1:Untagged 2:Tagged 3:Nonmember |
| 1.3.6.1.4.1.4756.20.302.40.1.235 | Columnf1000EASXPort4Member3RemoteB | read-write | current | RemoteB device card port 4 member 3: 0:Unmodify 1:Untagged 2:Tagged 3:Nonmember |
| 1.3.6.1.4.1.4756.20.302.40.1.236 | Columnf1000EASXPort4Member4RemoteB | read-write | current | RemoteB device card port 4 member 4: 0:Unmodify 1:Untagged 2:Tagged 3:Nonmember |
| 1.3.6.1.4.1.4756.20.302.40.1.237 | Columnf1000EASXPort4Member5RemoteB | read-write | current | RemoteB device card port 4 member 5: 0:Unmodify 1:Untagged 2:Tagged 3:Nonmember |
| 1.3.6.1.4.1.4756.20.302.40.1.238 | Columnf1000EASXPort4Member6RemoteB | read-write | current | RemoteB device card port 4 member 6: 0:Unmodify 1:Untagged 2:Tagged 3:Nonmember |
| 1.3.6.1.4.1.4756.20.302.40.1.239 | Columnf1000EASXPort4Member7RemoteB | read-write | current | RemoteB device card port 4 member 7: 0:Unmodify 1:Untagged 2:Tagged 3:Nonmember |
| 1.3.6.1.4.1.4756.20.302.40.1.240 | Columnf1000EASXPort4Member8RemoteB | read-write | current | RemoteB device card port 4 member 8: 0:Unmodify 1:Untagged 2:Tagged 3:Nonmember |
| 1.3.6.1.4.1.4756.20.302.40.1.241 | Columnf1000EASXPort4Member9RemoteB | read-write | current | RemoteB device card port 4 member 9: 0:Unmodify 1:Untagged 2:Tagged 3:Nonmember |
| 1.3.6.1.4.1.4756.20.302.40.1.242 | Columnf1000EASXPort4Member10RemoteB | read-write | current | RemoteB device card port 4 member 10: 0:Unmodify 1:Untagged 2:Tagged 3:Nonmember |
| 1.3.6.1.4.1.4756.20.302.40.1.243 | Columnf1000EASXPort4Member11RemoteB | read-write | current | RemoteB device card port 4 member 11: 0:Unmodify 1:Untagged 2:Tagged 3:Nonmember |
| 1.3.6.1.4.1.4756.20.302.40.1.244 | Columnf1000EASXPort4Member12RemoteB | read-write | current | RemoteB device card port 4 member 12: 0:Unmodify 1:Untagged 2:Tagged 3:Nonmember |
| 1.3.6.1.4.1.4756.20.302.40.1.245 | Columnf1000EASXPort4Member13RemoteB | read-write | current | RemoteB device card port 4 member 13: 0:Unmodify 1:Untagged 2:Tagged 3:Nonmember |
| 1.3.6.1.4.1.4756.20.302.40.1.246 | Columnf1000EASXPort4Member14RemoteB | read-write | current | RemoteB device card port 4 member 14: 0:Unmodify 1:Untagged 2:Tagged 3:Nonmember |
| 1.3.6.1.4.1.4756.20.302.40.1.247 | Columnf1000EASXPort4Member15RemoteB | read-write | current | RemoteB device card port 4 member 15: 0:Unmodify 1:Untagged 2:Tagged 3:Nonmember |
| 1.3.6.1.4.1.4756.20.302.40.1.248 | Columnf1000EASXPort4Member16RemoteB | read-write | current | RemoteB device card port 4 member 16: 0:Unmodify 1:Untagged 2:Tagged 3:Nonmember |
| 1.3.6.1.4.1.4756.20.302.40.1.249 | Columnf1000EASXIpAddressRemoteB | read-write | current | RemoteB device IP address |
| 1.3.6.1.4.1.4756.20.302.40.1.250 | Columnf1000EASXNetMaskRemoteB | read-write | current | RemoteB device Netmask |
| 1.3.6.1.4.1.4756.20.302.40.1.251 | Columnf1000EASXGateWayRemoteB | read-write | current | RemoteB device Gateway |
| 1.3.6.1.4.1.4756.20.302.40.1.252 | Columnf1000EASXSetDefaultRemoteB | read-write | current | RemoteB device set to default |
| 1.3.6.1.4.1.4756.20.302.40.1.253 | Columnf1000EASXFx1LinkAlarmRemoteB | read-write | current | RemoteB device fiber 1 link alarm 0:Disable 1:Enable |
| 1.3.6.1.4.1.4756.20.302.40.1.254 | Columnf1000EASXFx2LinkAlarmRemoteB | read-write | current | RemoteB device fiber 2 link alarm 0:Disable 1:Enable |
| 1.3.6.1.4.1.4756.20.302.40.1.255 | Columnf1000EASXUtp3LinkAlarmRemoteB | read-write | current | RemoteB device utp 3 link alarm 0:Disable 1:Enable |
| 1.3.6.1.4.1.4756.20.302.40.1.256 | Columnf1000EASXUtp4LinkAlarmRemoteB | read-write | current | RemoteB device utp 4 link alarm 0:Disable 1:Enable |
| 1.3.6.1.4.1.4756.20.302.40.1.257 | Columnf1000EASXFiber1FEFRemoteB | read-only | current | RemoteA device card fiber1 port FEF status: 0:Off 1:Detected |
| 1.3.6.1.4.1.4756.20.302.40.1.258 | Columnf1000EASXFiber2FEFRemoteB | read-only | current | RemoteA device card fiber2 port FEF status: 0:Off 1:Detected |
| 1.3.6.1.4.1.4756.20.302.40.1.259 | Columnf1000EASXFX1RXOctetsRemoteB | read-only | current | FRM220-1000EAS/X RMON Fiber 1 Receiver Octets. |
| 1.3.6.1.4.1.4756.20.302.40.1.260 | Columnf1000EASXFX1RXPacketRemoteB | read-only | current | FRM220-1000EAS/X RMON Fiber 1 Receiver Packets. |
| 1.3.6.1.4.1.4756.20.302.40.1.261 | Columnf1000EASXFX1RXBroadRemoteB | read-only | current | FRM220-1000EAS/X RMON Fiber 1 Receiver Broadcast Packets. |
| 1.3.6.1.4.1.4756.20.302.40.1.262 | Columnf1000EASXFX1RXMultiRemoteB | read-only | current | FRM220-1000EAS/X RMON Fiber 1 Receiver Multicast Packets. |
| 1.3.6.1.4.1.4756.20.302.40.1.263 | Columnf1000EASXFX1RXUniRemoteB | read-only | current | FRM220-1000EAS/X RMON Fiber 1 Receiver Unicast Packets. |
| 1.3.6.1.4.1.4756.20.302.40.1.264 | Columnf1000EASXFX1RXPauseRemoteB | read-only | current | FRM220-1000EAS/X RMON Fiber 1 Receiver Pause Packets. |
| 1.3.6.1.4.1.4756.20.302.40.1.265 | Columnf1000EASXFX1RXFCSERemoteB | read-only | current | FRM220-1000EAS/X RMON Fiber 1 Receiver FCS Error Packets. |
| 1.3.6.1.4.1.4756.20.302.40.1.266 | Columnf1000EASXFX1RXUnderRemoteB | read-only | current | FRM220-1000EAS/X RMON Fiber 1 Receiver Under Packets. |
| 1.3.6.1.4.1.4756.20.302.40.1.267 | Columnf1000EASXFX1RXOverRemoteB | read-only | current | FRM220-1000EAS/X RMON Fiber 1 Receiver Over Packets. |
| 1.3.6.1.4.1.4756.20.302.40.1.268 | Columnf1000EASXFX1RXJabberRemoteB | read-only | current | FRM220-1000EAS/X RMON Fiber 1 Receiver Jabber Packets. |
| 1.3.6.1.4.1.4756.20.302.40.1.269 | Columnf1000EASXFX1TXOctetsRemoteB | read-only | current | FRM220-1000EAS/X RMON Fiber 1 Transceiver Octets. |
| 1.3.6.1.4.1.4756.20.302.40.1.270 | Columnf1000EASXFX1TXPacketRemoteB | read-only | current | FRM220-1000EAS/X RMON Fiber 1 Transceiver Packets. |
| 1.3.6.1.4.1.4756.20.302.40.1.271 | Columnf1000EASXFX1TXBroadRemoteB | read-only | current | FRM220-1000EAS/X RMON Fiber 1 Transceiver Broadcast Packets. |
| 1.3.6.1.4.1.4756.20.302.40.1.272 | Columnf1000EASXFX1TXMultiRemoteB | read-only | current | FRM220-1000EAS/X RMON Fiber 1 Transceiver Multicast Packets. |
| 1.3.6.1.4.1.4756.20.302.40.1.273 | Columnf1000EASXFX1TXUniRemoteB | read-only | current | FRM220-1000EAS/X RMON Fiber 1 Transceiver Unicast Packets. |
| 1.3.6.1.4.1.4756.20.302.40.1.274 | Columnf1000EASXFX1TXPauseRemoteB | read-only | current | FRM220-1000EAS/X RMON Fiber 1 Transceiver Pause Packets. |
| 1.3.6.1.4.1.4756.20.302.40.1.275 | Columnf1000EASXFX1TXCollisionRemoteB | read-only | current | FRM220-1000EAS/X RMON Fiber 1 Transceiver Collision Packets. |
| 1.3.6.1.4.1.4756.20.302.40.1.276 | Columnf1000EASXFX10OctetsRemoteB | read-only | current | FRM220-1000EAS/X RMON Fiber 1 Transceiver/Receiver 0~64 Octets. |
| 1.3.6.1.4.1.4756.20.302.40.1.277 | Columnf1000EASXFX165OctetsRemoteB | read-only | current | FRM220-1000EAS/X RMON Fiber 1 Transceiver/Receiver 65~127 Octets. |
| 1.3.6.1.4.1.4756.20.302.40.1.278 | Columnf1000EASXFX1128OctetsRemoteB | read-only | current | FRM220-1000EAS/X RMON Fiber 1 Transceiver/Receiver 128~255 Octets. |
| 1.3.6.1.4.1.4756.20.302.40.1.279 | Columnf1000EASXFX1256OctetsRemoteB | read-only | current | FRM220-1000EAS/X RMON Fiber 1 Transceiver/Receiver 256~511 Octets. |
| 1.3.6.1.4.1.4756.20.302.40.1.280 | Columnf1000EASXFX1512OctetsRemoteB | read-only | current | FRM220-1000EAS/X RMON Fiber 1 Transceiver/Receiver 512~1023 Octets. |
| 1.3.6.1.4.1.4756.20.302.40.1.281 | Columnf1000EASXFX11024OctetsRemoteB | read-only | current | FRM220-1000EAS/X RMON Fiber 1 Transceiver/Receiver 1024~Max Octets. |
| 1.3.6.1.4.1.4756.20.302.40.1.282 | Columnf1000EASXFX2RXOctetsRemoteB | read-only | current | FRM220-1000EAS/X RMON Fiber 2 Receiver Octets. |
| 1.3.6.1.4.1.4756.20.302.40.1.283 | Columnf1000EASXFX2RXPacketRemoteB | read-only | current | FRM220-1000EAS/X RMON Fiber 2 Receiver Packets. |
| 1.3.6.1.4.1.4756.20.302.40.1.284 | Columnf1000EASXFX2RXBroadRemoteB | read-only | current | FRM220-1000EAS/X RMON Fiber 2 Receiver Broadcast Packets. |
| 1.3.6.1.4.1.4756.20.302.40.1.285 | Columnf1000EASXFX2RXMultiRemoteB | read-only | current | FRM220-1000EAS/X RMON Fiber 2 Receiver Multicast Packets. |
| 1.3.6.1.4.1.4756.20.302.40.1.286 | Columnf1000EASXFX2RXUniRemoteB | read-only | current | FRM220-1000EAS/X RMON Fiber 2 Receiver Unicast Packets. |
| 1.3.6.1.4.1.4756.20.302.40.1.287 | Columnf1000EASXFX2RXPauseRemoteB | read-only | current | FRM220-1000EAS/X RMON Fiber 2 Receiver Pause Packets. |
| 1.3.6.1.4.1.4756.20.302.40.1.288 | Columnf1000EASXFX2RXFCSERemoteB | read-only | current | FRM220-1000EAS/X RMON Fiber 2 Receiver FCS Error Packets. |
| 1.3.6.1.4.1.4756.20.302.40.1.289 | Columnf1000EASXFX2RXUnderRemoteB | read-only | current | FRM220-1000EAS/X RMON Fiber 2 Receiver Under Packets. |
| 1.3.6.1.4.1.4756.20.302.40.1.290 | Columnf1000EASXFX2RXOverRemoteB | read-only | current | FRM220-1000EAS/X RMON Fiber 2 Receiver Over Packets. |
| 1.3.6.1.4.1.4756.20.302.40.1.291 | Columnf1000EASXFX2RXJabberRemoteB | read-only | current | FRM220-1000EAS/X RMON Fiber 2 Receiver Jabber Packets. |
| 1.3.6.1.4.1.4756.20.302.40.1.292 | Columnf1000EASXFX2TXOctetsRemoteB | read-only | current | FRM220-1000EAS/X RMON Fiber 2 Transceiver Octets. |
| 1.3.6.1.4.1.4756.20.302.40.1.293 | Columnf1000EASXFX2TXPacketRemoteB | read-only | current | FRM220-1000EAS/X RMON Fiber 2 Transceiver Packets. |
| 1.3.6.1.4.1.4756.20.302.40.1.294 | Columnf1000EASXFX2TXBroadRemoteB | read-only | current | FRM220-1000EAS/X RMON Fiber 2 Transceiver Broadcast Packets. |
| 1.3.6.1.4.1.4756.20.302.40.1.295 | Columnf1000EASXFX2TXMultiRemoteB | read-only | current | FRM220-1000EAS/X RMON Fiber 2 Transceiver Multicast Packets. |
| 1.3.6.1.4.1.4756.20.302.40.1.296 | Columnf1000EASXFX2TXUniRemoteB | read-only | current | FRM220-1000EAS/X RMON Fiber 2 Transceiver Unicast Packets. |
| 1.3.6.1.4.1.4756.20.302.40.1.297 | Columnf1000EASXFX2TXPauseRemoteB | read-only | current | FRM220-1000EAS/X RMON Fiber 2 Transceiver Pause Packets. |
| 1.3.6.1.4.1.4756.20.302.40.1.298 | Columnf1000EASXFX2TXCollisionRemoteB | read-only | current | FRM220-1000EAS/X RMON Fiber 2 Transceiver Collision Packets. |
| 1.3.6.1.4.1.4756.20.302.40.1.299 | Columnf1000EASXFX20OctetsRemoteB | read-only | current | FRM220-1000EAS/X RMON Fiber 2 Transceiver/Receiver 0~64 Octets. |
| 1.3.6.1.4.1.4756.20.302.40.1.300 | Columnf1000EASXFX265OctetsRemoteB | read-only | current | FRM220-1000EAS/X RMON Fiber 2 Transceiver/Receiver 65~127 Octets. |
| 1.3.6.1.4.1.4756.20.302.40.1.301 | Columnf1000EASXFX2128OctetsRemoteB | read-only | current | FRM220-1000EAS/X RMON Fiber 2 Transceiver/Receiver 128~255 Octets. |
| 1.3.6.1.4.1.4756.20.302.40.1.302 | Columnf1000EASXFX2256OctetsRemoteB | read-only | current | FRM220-1000EAS/X RMON Fiber 2 Transceiver/Receiver 256~511 Octets. |
| 1.3.6.1.4.1.4756.20.302.40.1.303 | Columnf1000EASXFX2512OctetsRemoteB | read-only | current | FRM220-1000EAS/X RMON Fiber 2 Transceiver/Receiver 512~1023 Octets. |
| 1.3.6.1.4.1.4756.20.302.40.1.304 | Columnf1000EASXFX21024OctetsRemoteB | read-only | current | FRM220-1000EAS/X RMON Fiber 2 Transceiver/Receiver 1024~Max Octets. |
| 1.3.6.1.4.1.4756.20.302.40.1.305 | Columnf1000EASXUTP3RXOctetsRemoteB | read-only | current | FRM220-1000EAS/X RMON UTP 3 Receiver Octets. |
| 1.3.6.1.4.1.4756.20.302.40.1.306 | Columnf1000EASXUTP3RXPacketRemoteB | read-only | current | FRM220-1000EAS/X RMON UTP 3 Receiver Packets. |
| 1.3.6.1.4.1.4756.20.302.40.1.307 | Columnf1000EASXUTP3RXBroadRemoteB | read-only | current | FRM220-1000EAS/X RMON UTP 3 Receiver Broadcast Packets. |
| 1.3.6.1.4.1.4756.20.302.40.1.308 | Columnf1000EASXUTP3RXMultiRemoteB | read-only | current | FRM220-1000EAS/X RMON UTP 3 Receiver Multicast Packets. |
| 1.3.6.1.4.1.4756.20.302.40.1.309 | Columnf1000EASXUTP3RXUniRemoteB | read-only | current | FRM220-1000EAS/X RMON UTP 3 Receiver Unicast Packets. |
| 1.3.6.1.4.1.4756.20.302.40.1.310 | Columnf1000EASXUTP3RXPauseRemoteB | read-only | current | FRM220-1000EAS/X RMON UTP 3 Receiver Pause Packets. |
| 1.3.6.1.4.1.4756.20.302.40.1.311 | Columnf1000EASXUTP3RXFCSERemoteB | read-only | current | FRM220-1000EAS/X RMON UTP 3 Receiver FCS Error Packets. |
| 1.3.6.1.4.1.4756.20.302.40.1.312 | Columnf1000EASXUTP3RXUnderRemoteB | read-only | current | FRM220-1000EAS/X RMON UTP 3 Receiver Under Packets. |
| 1.3.6.1.4.1.4756.20.302.40.1.313 | Columnf1000EASXUTP3RXOverRemoteB | read-only | current | FRM220-1000EAS/X RMON UTP 3 Receiver Over Packets. |
| 1.3.6.1.4.1.4756.20.302.40.1.314 | Columnf1000EASXUTP3RXJabberRemoteB | read-only | current | FRM220-1000EAS/X RMON UTP 3 Receiver Jabber Packets. |
| 1.3.6.1.4.1.4756.20.302.40.1.315 | Columnf1000EASXUTP3TXOctetsRemoteB | read-only | current | FRM220-1000EAS/X RMON UTP 3 Transceiver Octets. |
| 1.3.6.1.4.1.4756.20.302.40.1.316 | Columnf1000EASXUTP3TXPacketRemoteB | read-only | current | FRM220-1000EAS/X RMON UTP 3 Transceiver Packets. |
| 1.3.6.1.4.1.4756.20.302.40.1.317 | Columnf1000EASXUTP3TXBroadRemoteB | read-only | current | FRM220-1000EAS/X RMON UTP 3 Transceiver Broadcast Packets. |
| 1.3.6.1.4.1.4756.20.302.40.1.318 | Columnf1000EASXUTP3TXMultiRemoteB | read-only | current | FRM220-1000EAS/X RMON UTP 3 Transceiver Multicast Packets. |
| 1.3.6.1.4.1.4756.20.302.40.1.319 | Columnf1000EASXUTP3TXUniRemoteB | read-only | current | FRM220-1000EAS/X RMON UTP 3 Transceiver Unicast Packets. |
| 1.3.6.1.4.1.4756.20.302.40.1.320 | Columnf1000EASXUTP3TXPauseRemoteB | read-only | current | FRM220-1000EAS/X RMON UTP 3 Transceiver Pause Packets. |
| 1.3.6.1.4.1.4756.20.302.40.1.321 | Columnf1000EASXUTP3TXCollisionRemoteB | read-only | current | FRM220-1000EAS/X RMON UTP 3 Transceiver Collision Packets. |
| 1.3.6.1.4.1.4756.20.302.40.1.322 | Columnf1000EASXUTP30OctetsRemoteB | read-only | current | FRM220-1000EAS/X RMON UTP 3 Transceiver/Receiver 0~64 Octets. |
| 1.3.6.1.4.1.4756.20.302.40.1.323 | Columnf1000EASXUTP365OctetsRemoteB | read-only | current | FRM220-1000EAS/X RMON UTP 3 Transceiver/Receiver 65~127 Octets. |
| 1.3.6.1.4.1.4756.20.302.40.1.324 | Columnf1000EASXUTP3128OctetsRemoteB | read-only | current | FRM220-1000EAS/X RMON UTP 3 Transceiver/Receiver 128~255 Octets. |
| 1.3.6.1.4.1.4756.20.302.40.1.325 | Columnf1000EASXUTP3256OctetsRemoteB | read-only | current | FRM220-1000EAS/X RMON UTP 3 Transceiver/Receiver 256~511 Octets. |
| 1.3.6.1.4.1.4756.20.302.40.1.326 | Columnf1000EASXUTP3512OctetsRemoteB | read-only | current | FRM220-1000EAS/X RMON UTP 3 Transceiver/Receiver 512~1023 Octets. |
| 1.3.6.1.4.1.4756.20.302.40.1.327 | Columnf1000EASXUTP31024OctetsRemoteB | read-only | current | FRM220-1000EAS/X RMON UTP 3 Transceiver/Receiver 1024~Max Octets. |
| 1.3.6.1.4.1.4756.20.302.40.1.328 | Columnf1000EASXUTP4RXOctetsRemoteB | read-only | current | FRM220-1000EAS/X RMON UTP 4 Receiver Octets. |
| 1.3.6.1.4.1.4756.20.302.40.1.329 | Columnf1000EASXUTP4RXPacketRemoteB | read-only | current | FRM220-1000EAS/X RMON UTP 4 Receiver Packets. |
| 1.3.6.1.4.1.4756.20.302.40.1.330 | Columnf1000EASXUTP4RXBroadRemoteB | read-only | current | FRM220-1000EAS/X RMON UTP 4 Receiver Broadcast Packets. |
| 1.3.6.1.4.1.4756.20.302.40.1.331 | Columnf1000EASXUTP4RXMultiRemoteB | read-only | current | FRM220-1000EAS/X RMON UTP 4 Receiver Multicast Packets. |
| 1.3.6.1.4.1.4756.20.302.40.1.332 | Columnf1000EASXUTP4RXUniRemoteB | read-only | current | FRM220-1000EAS/X RMON UTP 4 Receiver Unicast Packets. |
| 1.3.6.1.4.1.4756.20.302.40.1.333 | Columnf1000EASXUTP4RXPauseRemoteB | read-only | current | FRM220-1000EAS/X RMON UTP 4 Receiver Pause Packets. |
| 1.3.6.1.4.1.4756.20.302.40.1.334 | Columnf1000EASXUTP4RXFCSERemoteB | read-only | current | FRM220-1000EAS/X RMON UTP 4 Receiver FCS Error Packets. |
| 1.3.6.1.4.1.4756.20.302.40.1.335 | Columnf1000EASXUTP4RXUnderRemoteB | read-only | current | FRM220-1000EAS/X RMON UTP 4 Receiver Under Packets. |
| 1.3.6.1.4.1.4756.20.302.40.1.336 | Columnf1000EASXUTP4RXOverRemoteB | read-only | current | FRM220-1000EAS/X RMON UTP 4 Receiver Over Packets. |
| 1.3.6.1.4.1.4756.20.302.40.1.337 | Columnf1000EASXUTP4RXJabberRemoteB | read-only | current | FRM220-1000EAS/X RMON UTP 4 Receiver Jabber Packets. |
| 1.3.6.1.4.1.4756.20.302.40.1.338 | Columnf1000EASXUTP4TXOctetsRemoteB | read-only | current | FRM220-1000EAS/X RMON UTP 4 Transceiver Octets. |
| 1.3.6.1.4.1.4756.20.302.40.1.339 | Columnf1000EASXUTP4TXPacketRemoteB | read-only | current | FRM220-1000EAS/X RMON UTP 4 Transceiver Packets. |
| 1.3.6.1.4.1.4756.20.302.40.1.340 | Columnf1000EASXUTP4TXBroadRemoteB | read-only | current | FRM220-1000EAS/X RMON UTP 4 Transceiver Broadcast Packets. |
| 1.3.6.1.4.1.4756.20.302.40.1.341 | Columnf1000EASXUTP4TXMultiRemoteB | read-only | current | FRM220-1000EAS/X RMON UTP 4 Transceiver Multicast Packets. |
| 1.3.6.1.4.1.4756.20.302.40.1.342 | Columnf1000EASXUTP4TXUniRemoteB | read-only | current | FRM220-1000EAS/X RMON UTP 4 Transceiver Unicast Packets. |
| 1.3.6.1.4.1.4756.20.302.40.1.343 | Columnf1000EASXUTP4TXPauseRemoteB | read-only | current | FRM220-1000EAS/X RMON UTP 4 Transceiver Pause Packets. |
| 1.3.6.1.4.1.4756.20.302.40.1.344 | Columnf1000EASXUTP4TXCollisionRemoteB | read-only | current | FRM220-1000EAS/X RMON UTP 4 Transceiver Collision Packets. |
| 1.3.6.1.4.1.4756.20.302.40.1.345 | Columnf1000EASXUTP40OctetsRemoteB | read-only | current | FRM220-1000EAS/X RMON UTP 4 Transceiver/Receiver 0~64 Octets. |
| 1.3.6.1.4.1.4756.20.302.40.1.346 | Columnf1000EASXUTP465OctetsRemoteB | read-only | current | FRM220-1000EAS/X RMON UTP 4 Transceiver/Receiver 65~127 Octets. |
| 1.3.6.1.4.1.4756.20.302.40.1.347 | Columnf1000EASXUTP4128OctetsRemoteB | read-only | current | FRM220-1000EAS/X RMON UTP 4 Transceiver/Receiver 128~255 Octets. |
| 1.3.6.1.4.1.4756.20.302.40.1.348 | Columnf1000EASXUTP4256OctetsRemoteB | read-only | current | FRM220-1000EAS/X RMON UTP 4 Transceiver/Receiver 256~511 Octets. |
| 1.3.6.1.4.1.4756.20.302.40.1.349 | Columnf1000EASXUTP4512OctetsRemoteB | read-only | current | FRM220-1000EAS/X RMON UTP 4 Transceiver/Receiver 512~1023 Octets. |
| 1.3.6.1.4.1.4756.20.302.40.1.350 | Columnf1000EASXUTP41024OctetsRemoteB | read-only | current | FRM220-1000EAS/X RMON UTP 4 Transceiver/Receiver 1024~Max Octets. |
| 1.3.6.1.4.1.4756.20.310 | Nodef100mLocalCards | |||
| 1.3.6.1.4.1.4756.20.310.20 | Tablef100mLocalTable | not-accessible | current | A list of local FRM220-F100M series card entries. The number of entries is f100m-No-L. |
| 1.3.6.1.4.1.4756.20.310.20.1 | Rowf100mLocalEntry | not-accessible | current | An entry containing management information applicable to a particular local FRM220-F100M series card. |
| 1.3.6.1.4.1.4756.20.310.20.1.1 | Columnf100mChassisIndexLocal | read-only | current | A unique value for each local card. It is the chassis location number. |
| 1.3.6.1.4.1.4756.20.310.20.1.2 | Columnf100mSlotIndexLocal | read-only | current | A unique value for each local card. It is the slot location number. |
| 1.3.6.1.4.1.4756.20.310.20.1.3 | Columnf100mCardHWVerLocal | read-only | current | Local FRM220-F100M Series card hardware version x.xxx |
| 1.3.6.1.4.1.4756.20.310.20.1.4 | Columnf100mCardFWVerLocal | read-only | current | Local FRM220-F100M Series card firmware version x.xxx |
| 1.3.6.1.4.1.4756.20.310.20.1.5 | Columnf100mCardCPLDVerLocal | read-only | current | Local FRM220-F100M Series card CPLD version x.xxx |
| 1.3.6.1.4.1.4756.20.310.20.1.6 | Columnf100mCardFPGAVerLocal | read-only | current | Local FRM220-F100M Series card FPGA version x.xxx |
| 1.3.6.1.4.1.4756.20.310.20.1.7 | Columnf100mPortActiveLocal | read-write | current | Local FRM220-F100M Series card active: 0:Disable 1:Enable |
| 1.3.6.1.4.1.4756.20.310.20.1.8 | Columnf100mSettoDefaultLocal | read-write | current | Local FRM220-F100M Series card set to default: 0:OFF 1:Action |
| 1.3.6.1.4.1.4756.20.310.20.1.9 | Columnf100mPortResetLocal | read-write | current | Local FRM220-F100M Series card portreset: 0:OFF 1:Action |
| 1.3.6.1.4.1.4756.20.310.20.1.10 | Columnf100mModelLocal | read-only | current | Local FRM220-F100/1000MS Card Type: 0:100M 1:100MS 2:1000M 3:1000MS |
| 1.3.6.1.4.1.4756.20.310.20.1.11 | Columnf100mFxLinkLocal | read-only | current | Local FRM220-F100M fiber link status: 0:Down 1:up |
| 1.3.6.1.4.1.4756.20.310.20.1.12 | Columnf100mFxActiveLocal | read-write | current | Local FRM220-F100M fiber active: 0:Disable 1:Enable |
| 1.3.6.1.4.1.4756.20.310.20.1.13 | Columnf100mFxNegoLocal | read-write | current | Local FRM220-F100M fiber negotiation: 0:Manual 1:Auto |
| 1.3.6.1.4.1.4756.20.310.20.1.14 | Columnf100mFxSpeedLocal | read-write | current | Local FRM220-F100M fiber speed: 0:100M 1:1000M |
| 1.3.6.1.4.1.4756.20.310.20.1.15 | Columnf100mFxSpeedSTSLocal | read-only | current | Local FRM220-F100M loopback mode: 0:100M 1:1000M |
| 1.3.6.1.4.1.4756.20.310.20.1.16 | Columnf100mFxManagementLocal | read-write | current | Local FRM220-F100M fiber management: 0:Disalbe 1:Enable |
| 1.3.6.1.4.1.4756.20.310.20.1.17 | Columnf100mFxFlowCnlSLocal | read-write | current | Local FRM220-F100M fiber flow control: 0:Disalbe 1:Enable |
| 1.3.6.1.4.1.4756.20.310.20.1.18 | Columnf100mFxIRLimiteLocal | read-write | current | Local FRM220-F100M fiber IRL limit: 0:Disalbe 1:Enable |
| 1.3.6.1.4.1.4756.20.310.20.1.19 | Columnf100mFxIRLLocal | read-write | current | Local FRM220-F100M fiber IRL index N * 64K |
| 1.3.6.1.4.1.4756.20.310.20.1.20 | Columnf100mFxERLimiteLocal | read-write | current | Local FRM220-F100M fiber ERL limite: 0:Disalbe 1:Enable |
| 1.3.6.1.4.1.4756.20.310.20.1.21 | Columnf100mFxERLLocal | read-write | current | Local FRM220-F100M fiber ERL index N * 64K |
| 1.3.6.1.4.1.4756.20.310.20.1.22 | Columnf100mUtpActiveLocal | read-write | current | Local FRM220-F100M UTP active: 0:Disable 1:Enable |
| 1.3.6.1.4.1.4756.20.310.20.1.23 | Columnf100mUtpLinkLocal | read-only | current | Local FRM220-F100M UTP link: 0:Down 1:Up |
| 1.3.6.1.4.1.4756.20.310.20.1.24 | Columnf100mUtpNegoLocal | read-write | current | Local FRM220-F100M UTP negotiation: 0:Manual 1:Auto |
| 1.3.6.1.4.1.4756.20.310.20.1.25 | Columnf100mUtpSpeedLocal | read-write | current | Local FRM220-F100M UTP speed: 0:10M 1:100M 2:1000M |
| 1.3.6.1.4.1.4756.20.310.20.1.26 | Columnf100mUtpDuplexLocal | read-write | current | Local FRM220-F100M UTP duplex: 0:Half 1:Full |
| 1.3.6.1.4.1.4756.20.310.20.1.27 | Columnf100mUtpSpeedSTSLocal | read-only | current | Local FRM220-F100M UTP speed status: 0:10M 1:100M 2:1000M |
| 1.3.6.1.4.1.4756.20.310.20.1.28 | Columnf100mUtpDuplexSTSLocal | read-only | current | Local FRM220-F100M UTP duplex status: 0:Half 1:Full |
| 1.3.6.1.4.1.4756.20.310.20.1.29 | Columnf100mUtpFlowCnlLocal | read-write | current | Local FRM220-F100M UTP flow control: 0:Disable 1:Enable |
| 1.3.6.1.4.1.4756.20.310.20.1.30 | Columnf100mUtpIRLimiteLocal | read-write | current | Local FRM220-F100M UTP IRL limit: 0:Disable 1:Enable |
| 1.3.6.1.4.1.4756.20.310.20.1.31 | Columnf100mUtpIRLLocal | read-write | current | Local FRM220-F100M UTP IRL index N * 64K |
| 1.3.6.1.4.1.4756.20.310.20.1.32 | Columnf100mUtpERLimiteLocal | read-write | current | Local FRM220-F100M UTP ERL limit: 0:Disable 1:Enable |
| 1.3.6.1.4.1.4756.20.310.20.1.33 | Columnf100mUtpERLLocal | read-write | current | Local FRM220-F100M UTP ERL index N * 64K |
| 1.3.6.1.4.1.4756.20.310.20.1.34 | Columnf100mIpAddrLocal | read-write | current | Local FRM220-F100M IP address |
| 1.3.6.1.4.1.4756.20.310.20.1.35 | Columnf100mNetmaskLocal | read-write | current | Local FRM220-F100M Netmask |
| 1.3.6.1.4.1.4756.20.310.20.1.36 | Columnf100mGatewayLocal | read-write | current | Local FRM220-F100M Gateway |
| 1.3.6.1.4.1.4756.20.310.20.1.37 | Columnf100mAlsModeLocal | read-write | current | Local FRM220-F100M Auto Laser Shut Down: 0:Disable 1:Enable |
| 1.3.6.1.4.1.4756.20.310.20.1.38 | Columnf100mLfpModeLocal | read-write | current | Local FRM220-F100M Link fault pass through: 0:Disable 1:Enable |
| 1.3.6.1.4.1.4756.20.310.20.1.39 | Columnf100mDHCPLocal | read-write | current | Local FRM220-F100M DHCP: 0:Disable 1:Enable |
| 1.3.6.1.4.1.4756.20.310.20.1.40 | Columnf100mRemotePWRLocal | read-only | current | Local FRM220-F100M remote power: 0:Ok 1:Abnormal |
| 1.3.6.1.4.1.4756.20.310.20.1.41 | Columnf100mJumboFrameLocal | read-write | current | Local FRM220-F100M jumbo frame: 0:Disable 1:Enable |
| 1.3.6.1.4.1.4756.20.310.20.1.42 | Columnf100mCrcLocal | read-write | current | Local FRM220-F100M crc: 0:OFF 1:ON |
| 1.3.6.1.4.1.4756.20.310.20.1.43 | Columnf100mPauseFrameLocal | read-write | current | Local FRM220-F100M pause frame: 0:Disable 1:Enable |
| 1.3.6.1.4.1.4756.20.310.20.1.44 | Columnf100mQosLocal | read-write | current | Local FRM220-F100M pause frame: 0:Disable 1:Enable |
| 1.3.6.1.4.1.4756.20.310.20.1.45 | Columnf100mBsFilterLocal | read-write | current | Local FRM220-F100M Brosdcast Storm Filter : 0:Disable 1:Enalbe |
| 1.3.6.1.4.1.4756.20.310.20.1.46 | Columnf100mMsFilterLocal | read-write | current | Local FRM220-F100M Multicast Storm Filter: 0:Disable 1:Enable |
| 1.3.6.1.4.1.4756.20.310.20.1.47 | Columnf100mUnDaFilterLocal | read-write | current | Local FRM220-F100M Unknown DA Unicast Storm Filter: 0:Disable 1:Enable |
| 1.3.6.1.4.1.4756.20.310.20.1.48 | Columnf100mTpVLANNBLocal | read-write | current | Local FRM220-F100M Tp VLAN number: |
| 1.3.6.1.4.1.4756.20.310.20.1.49 | Columnf100mTpFrameGressLocal | read-write | current | Local FRM220-F100M TP Frame Egress Type: 0:Replace Tag 1:Remove Tag 2:Add Tag 3:Don't Touch Tag |
| 1.3.6.1.4.1.4756.20.310.20.1.50 | Columnf100mFxVLANNBLocal | read-write | current | Local FRM220-F100M Fx VLAN number: |
| 1.3.6.1.4.1.4756.20.310.20.1.51 | Columnf100mFxFrameGressLocal | read-write | current | Local FRM220-F100M Fx Frame Egress Type: 0:Replace Tag 1:Remove Tag 2:Add Tag 3:Don't Touch Tag |
| 1.3.6.1.4.1.4756.20.310.20.1.52 | Columnf100mCpuVLANNBLocal | read-write | current | Local FRM220-F100M Cpu VLAN number: |
| 1.3.6.1.4.1.4756.20.310.20.1.53 | Columnf100mCpuFrameGressLocal | read-write | current | Local FRM220-F100M Cpu Frame Egress Type: 0:Replace Tag 1:Remove Tag 2:Add Tag 3:Don't Touch Tag |
| 1.3.6.1.4.1.4756.20.310.20.1.54 | Columnf100mVLANGpLocal | read-write | current | Local FRM220-F100M VLAN Group : 0:Disable 1:Enalbe |
| 1.3.6.1.4.1.4756.20.310.20.1.55 | Columnf100mTpMember0Local | read-write | current | Local FRM220-F100M Tp Member 0: 0:Disalbe 1:Enable |
| 1.3.6.1.4.1.4756.20.310.20.1.56 | Columnf100mTpMember1Local | read-write | current | Local FRM220-F100M Tp Member 1: 0:Disalbe 1:Enable |
| 1.3.6.1.4.1.4756.20.310.20.1.57 | Columnf100mTpMember2Local | read-write | current | Local FRM220-F100M Tp Member 2: 0:Disalbe 1:Enable |
| 1.3.6.1.4.1.4756.20.310.20.1.58 | Columnf100mTpMember3Local | read-write | current | Local FRM220-F100M Tp Member 3: 0:Disalbe 1:Enable |
| 1.3.6.1.4.1.4756.20.310.20.1.59 | Columnf100mTpMember4Local | read-write | current | Local FRM220-F100M Tp Member 4: 0:Disalbe 1:Enable |
| 1.3.6.1.4.1.4756.20.310.20.1.60 | Columnf100mTpMember5Local | read-write | current | Local FRM220-F100M Tp Member 5: 0:Disalbe 1:Enable |
| 1.3.6.1.4.1.4756.20.310.20.1.61 | Columnf100mTpMember6Local | read-write | current | Local FRM220-F100M Tp Member 6: 0:Disalbe 1:Enable |
| 1.3.6.1.4.1.4756.20.310.20.1.62 | Columnf100mTpMember7Local | read-write | current | Local FRM220-F100M Tp Member 7: 0:Disalbe 1:Enable |
| 1.3.6.1.4.1.4756.20.310.20.1.63 | Columnf100mTpMember8Local | read-write | current | Local FRM220-F100M Tp Member 8: 0:Disalbe 1:Enable |
| 1.3.6.1.4.1.4756.20.310.20.1.64 | Columnf100mTpMember9Local | read-write | current | Local FRM220-F100M Tp Member 9: 0:Disalbe 1:Enable |
| 1.3.6.1.4.1.4756.20.310.20.1.65 | Columnf100mTpMember10Local | read-write | current | Local FRM220-F100M Tp Member 10: 0:Disalbe 1:Enable |
| 1.3.6.1.4.1.4756.20.310.20.1.66 | Columnf100mTpMember11Local | read-write | current | Local FRM220-F100M Tp Member 11: 0:Disalbe 1:Enable |
| 1.3.6.1.4.1.4756.20.310.20.1.67 | Columnf100mTpMember12Local | read-write | current | Local FRM220-F100M Tp Member 12: 0:Disalbe 1:Enable |
| 1.3.6.1.4.1.4756.20.310.20.1.68 | Columnf100mTpMember13Local | read-write | current | Local FRM220-F100M Tp Member 13: 0:Disalbe 1:Enable |
| 1.3.6.1.4.1.4756.20.310.20.1.69 | Columnf100mTpMember14Local | read-write | current | Local FRM220-F100M Tp Member 14: 0:Disalbe 1:Enable |
| 1.3.6.1.4.1.4756.20.310.20.1.70 | Columnf100mTpMember15Local | read-write | current | Local FRM220-F100M Tp Member 15: 0:Disalbe 1:Enable |
| 1.3.6.1.4.1.4756.20.310.20.1.71 | Columnf100mFxMember0Local | read-write | current | Local FRM220-F100M Fx Member 0: 0:Disalbe 1:Enable |
| 1.3.6.1.4.1.4756.20.310.20.1.72 | Columnf100mFxMember1Local | read-write | current | Local FRM220-F100M Fx Member 1: 0:Disalbe 1:Enable |
| 1.3.6.1.4.1.4756.20.310.20.1.73 | Columnf100mFxMember2Local | read-write | current | Local FRM220-F100M Fx Member 2: 0:Disalbe 1:Enable |
| 1.3.6.1.4.1.4756.20.310.20.1.74 | Columnf100mFxMember3Local | read-write | current | Local FRM220-F100M Fx Member 3: 0:Disalbe 1:Enable |
| 1.3.6.1.4.1.4756.20.310.20.1.75 | Columnf100mFxMember4Local | read-write | current | Local FRM220-F100M Fx Member 4: 0:Disalbe 1:Enable |
| 1.3.6.1.4.1.4756.20.310.20.1.76 | Columnf100mFxMember5Local | read-write | current | Local FRM220-F100M Fx Member 5: 0:Disalbe 1:Enable |
| 1.3.6.1.4.1.4756.20.310.20.1.77 | Columnf100mFxMember6Local | read-write | current | Local FRM220-F100M Fx Member 6: 0:Disalbe 1:Enable |
| 1.3.6.1.4.1.4756.20.310.20.1.78 | Columnf100mFxMember7Local | read-write | current | Local FRM220-F100M Fx Member 7: 0:Disalbe 1:Enable |
| 1.3.6.1.4.1.4756.20.310.20.1.79 | Columnf100mFxMember8Local | read-write | current | Local FRM220-F100M Fx Member 8: 0:Disalbe 1:Enable |
| 1.3.6.1.4.1.4756.20.310.20.1.80 | Columnf100mFxMember9Local | read-write | current | Local FRM220-F100M Fx Member 9: 0:Disalbe 1:Enable |
| 1.3.6.1.4.1.4756.20.310.20.1.81 | Columnf100mFxMember10Local | read-write | current | Local FRM220-F100M Fx Member 10: 0:Disalbe 1:Enable |
| 1.3.6.1.4.1.4756.20.310.20.1.82 | Columnf100mFxMember11Local | read-write | current | Local FRM220-F100M Fx Member 11: 0:Disalbe 1:Enable |
| 1.3.6.1.4.1.4756.20.310.20.1.83 | Columnf100mFxMember12Local | read-write | current | Local FRM220-F100M Fx Member 12: 0:Disalbe 1:Enable |
| 1.3.6.1.4.1.4756.20.310.20.1.84 | Columnf100mFxMember13Local | read-write | current | Local FRM220-F100M Fx Member 13: 0:Disalbe 1:Enable |
| 1.3.6.1.4.1.4756.20.310.20.1.85 | Columnf100mFxMember14Local | read-write | current | Local FRM220-F100M Fx Member 14: 0:Disalbe 1:Enable |
| 1.3.6.1.4.1.4756.20.310.20.1.86 | Columnf100mFxMember15Local | read-write | current | Local FRM220-F100M Fx Member 15: 0:Disalbe 1:Enable |
| 1.3.6.1.4.1.4756.20.310.20.1.87 | Columnf100mCpuMember0Local | read-write | current | Local FRM220-F100M Cpu Member 0: 0:Disalbe 1:Enable |
| 1.3.6.1.4.1.4756.20.310.20.1.88 | Columnf100mCpuMember1Local | read-write | current | Local FRM220-F100M Cpu Member 1: 0:Disalbe 1:Enable |
| 1.3.6.1.4.1.4756.20.310.20.1.89 | Columnf100mCpuMember2Local | read-write | current | Local FRM220-F100M Cpu Member 2: 0:Disalbe 1:Enable |
| 1.3.6.1.4.1.4756.20.310.20.1.90 | Columnf100mCpuMember3Local | read-write | current | Local FRM220-F100M Cpu Member 3: 0:Disalbe 1:Enable |
| 1.3.6.1.4.1.4756.20.310.20.1.91 | Columnf100mCpuMember4Local | read-write | current | Local FRM220-F100M Cpu Member 4: 0:Disalbe 1:Enable |
| 1.3.6.1.4.1.4756.20.310.20.1.92 | Columnf100mCpuMember5Local | read-write | current | Local FRM220-F100M Cpu Member 5: 0:Disalbe 1:Enable |
| 1.3.6.1.4.1.4756.20.310.20.1.93 | Columnf100mCpuMember6Local | read-write | current | Local FRM220-F100M Cpu Member 6: 0:Disalbe 1:Enable |
| 1.3.6.1.4.1.4756.20.310.20.1.94 | Columnf100mCpuMember7Local | read-write | current | Local FRM220-F100M Cpu Member 7: 0:Disalbe 1:Enable |
| 1.3.6.1.4.1.4756.20.310.20.1.95 | Columnf100mCpuMember8Local | read-write | current | Local FRM220-F100M Cpu Member 8: 0:Disalbe 1:Enable |
| 1.3.6.1.4.1.4756.20.310.20.1.96 | Columnf100mCpuMember9Local | read-write | current | Local FRM220-F100M Cpu Member 9: 0:Disalbe 1:Enable |
| 1.3.6.1.4.1.4756.20.310.20.1.97 | Columnf100mCpuMember10Local | read-write | current | Local FRM220-F100M Cpu Member 10: 0:Disalbe 1:Enable |
| 1.3.6.1.4.1.4756.20.310.20.1.98 | Columnf100mCpuMember11Local | read-write | current | Local FRM220-F100M Cpu Member 11: 0:Disalbe 1:Enable |
| 1.3.6.1.4.1.4756.20.310.20.1.99 | Columnf100mCpuMember12Local | read-write | current | Local FRM220-F100M Cpu Member 12: 0:Disalbe 1:Enable |
| 1.3.6.1.4.1.4756.20.310.20.1.100 | Columnf100mCpuMember13Local | read-write | current | Local FRM220-F100M Cpu Member 13: 0:Disalbe 1:Enable |
| 1.3.6.1.4.1.4756.20.310.20.1.101 | Columnf100mCpuMember14Local | read-write | current | Local FRM220-F100M Cpu Member 14: 0:Disalbe 1:Enable |
| 1.3.6.1.4.1.4756.20.310.20.1.102 | Columnf100mCpuMember15Local | read-write | current | Local FRM220-F100M Cpu Member 15: 0:Disalbe 1:Enable |
| 1.3.6.1.4.1.4756.20.310.20.1.103 | Columnf100mPVID0Local | read-write | current | Local FRM220-F100M Port 0 VID : |
| 1.3.6.1.4.1.4756.20.310.20.1.104 | Columnf100mPVID1Local | read-write | current | Local FRM220-F100M Port 1 VID : |
| 1.3.6.1.4.1.4756.20.310.20.1.105 | Columnf100mPVID2Local | read-write | current | Local FRM220-F100M Port 2 VID : |
| 1.3.6.1.4.1.4756.20.310.20.1.106 | Columnf100mPVID3Local | read-write | current | Local FRM220-F100M Port 3 VID : |
| 1.3.6.1.4.1.4756.20.310.20.1.107 | Columnf100mPVID4Local | read-write | current | Local FRM220-F100M Port 4 VID : |
| 1.3.6.1.4.1.4756.20.310.20.1.108 | Columnf100mPVID5Local | read-write | current | Local FRM220-F100M Port 5 VID : |
| 1.3.6.1.4.1.4756.20.310.20.1.109 | Columnf100mPVID6Local | read-write | current | Local FRM220-F100M Port 6 VID : |
| 1.3.6.1.4.1.4756.20.310.20.1.110 | Columnf100mPVID7Local | read-write | current | Local FRM220-F100M Port 7 VID : |
| 1.3.6.1.4.1.4756.20.310.20.1.111 | Columnf100mPVID8Local | read-write | current | Local FRM220-F100M Port 8 VID : |
| 1.3.6.1.4.1.4756.20.310.20.1.112 | Columnf100mPVID9Local | read-write | current | Local FRM220-F100M Port 9 VID : |
| 1.3.6.1.4.1.4756.20.310.20.1.113 | Columnf100mPVID10Local | read-write | current | Local FRM220-F100M Port 10 VID : |
| 1.3.6.1.4.1.4756.20.310.20.1.114 | Columnf100mPVID11Local | read-write | current | Local FRM220-F100M Port 11 VID : |
| 1.3.6.1.4.1.4756.20.310.20.1.115 | Columnf100mPVID12Local | read-write | current | Local FRM220-F100M Port 12 VID : |
| 1.3.6.1.4.1.4756.20.310.20.1.116 | Columnf100mPVID13Local | read-write | current | Local FRM220-F100M Port 13 VID : |
| 1.3.6.1.4.1.4756.20.310.20.1.117 | Columnf100mPVID14Local | read-write | current | Local FRM220-F100M Port 14 VID : |
| 1.3.6.1.4.1.4756.20.310.20.1.118 | Columnf100mPVID15Local | read-write | current | Local FRM220-F100M Port 15 VID : |
| 1.3.6.1.4.1.4756.20.310.20.1.119 | Columnf100mDoubleVLANLocal | read-write | current | Local FRM220-F100M Double VLAN: 0:Disable 1:Enable |
| 1.3.6.1.4.1.4756.20.310.20.1.120 | Columnf100mDoubleVLANTagPriorityLocal | read-write | current | Local FRM220-F100M Double VLAN Tag Priority : 0:Internal 1:Remark |
| 1.3.6.1.4.1.4756.20.310.20.1.121 | Columnf100mDoubleVLANDirectionLocal | read-write | current | Local FRM220-F100M Double VLAN Direction : 0:TP add,FX Remove 1:FX add,TP Remove |
| 1.3.6.1.4.1.4756.20.310.20.1.122 | Columnf100mDoubleVLANTagTypeLocal | read-only | current | Local FRM220-F100M Tag Type (HEX) : |
| 1.3.6.1.4.1.4756.20.310.20.1.123 | Columnf100mDoubleVLANVIDLocal | read-write | current | Local FRM220-F100M Double VLAN VID : |
| 1.3.6.1.4.1.4756.20.310.20.1.124 | Columnf100mFxDDLocal | read-only | current | Local device card fiber Digital Diagnostic function: 0:No 1:Yes |
| 1.3.6.1.4.1.4756.20.310.20.1.125 | Columnf100mDDVendorLocal | read-only | current | Local device card fiber D/D information: Vendor name |
| 1.3.6.1.4.1.4756.20.310.20.1.126 | Columnf100mDDPartNoLocal | read-only | current | Local device card fiber D/D information: Vendor part number |
| 1.3.6.1.4.1.4756.20.310.20.1.127 | Columnf100mDDFiberTypeLocal | read-only | current | Local device card fiber D/D information: Fiber Type |
| 1.3.6.1.4.1.4756.20.310.20.1.128 | Columnf100mDDWaveLenLocal | read-only | current | Local device card fiber D/D information: Wave length |
| 1.3.6.1.4.1.4756.20.310.20.1.129 | Columnf100mDDWaveLen2Local | read-only | current | Local device card fiber D/D information: Wave length 2 |
| 1.3.6.1.4.1.4756.20.310.20.1.130 | Columnf100mDDLinkLenLocal | read-only | current | Local device card fiber D/D information: Link length |
| 1.3.6.1.4.1.4756.20.310.20.1.131 | Columnf100mDDLenUnitLocal | read-only | current | Local device card fiber D/D information: Length Unit |
| 1.3.6.1.4.1.4756.20.310.20.1.132 | Columnf100mDDStatusLocal | read-only | current | Local device card fiber D/D information: Status Support |
| 1.3.6.1.4.1.4756.20.310.20.1.133 | Columnf100mDDRxSensLocal | read-only | current | Local device card fiber D/D information: Rx Sensitivity |
| 1.3.6.1.4.1.4756.20.310.20.1.134 | Columnf100mDDTxPWRLocal | read-only | current | Local device card fiber D/D information: Tx power |
| 1.3.6.1.4.1.4756.20.310.20.1.135 | Columnf100mDDRxPWRLocal | read-only | current | Local device card fiber D/D information: Rx power |
| 1.3.6.1.4.1.4756.20.310.20.1.136 | Columnf100mDDTempLocal | read-only | current | Local device card fiber D/D information: Temperature in degree C |
| 1.3.6.1.4.1.4756.20.310.20.1.137 | Columnf100mDDPWRMarginLocal | read-only | current | Local device card fiber D/D information: Power margin |
| 1.3.6.1.4.1.4756.20.310.20.1.138 | Columnf100mLBStartLocal | read-write | current | Local device card Loop back test : 1:Off 2:Action |
| 1.3.6.1.4.1.4756.20.310.20.1.139 | Columnf100mLBStartStatusLocal | read-only | current | Local device card Loop back test status : 1:Normal 2:Ok 3:Fail |
| 1.3.6.1.4.1.4756.20.311 | Nodef100mRemoteCards | |||
| 1.3.6.1.4.1.4756.20.311.20 | Tablef100mRemoteTable | not-accessible | current | A list of local FRM220-F100M series card entries. The number of entries is f100m-No-R. |
| 1.3.6.1.4.1.4756.20.311.20.1 | Rowf100mRemoteEntry | not-accessible | current | An entry containing management information applicable to a particular remote FRM220-F100M series card. |
| 1.3.6.1.4.1.4756.20.311.20.1.1 | Columnf100mChassisIndexRemote | read-only | current | A unique value for each local card. It is the chassis location number. |
| 1.3.6.1.4.1.4756.20.311.20.1.2 | Columnf100mSlotIndexRemote | read-only | current | A unique value for each local card. It is the slot location number. |
| 1.3.6.1.4.1.4756.20.311.20.1.3 | Columnf100mCardHWVerRemote | read-only | current | Remote FRM220-F100M Series card hardware version x.xxx |
| 1.3.6.1.4.1.4756.20.311.20.1.4 | Columnf100mCardFWVerRemote | read-only | current | Remote FRM220-F100M Series card firmware version x.xxx |
| 1.3.6.1.4.1.4756.20.311.20.1.5 | Columnf100mCardCPLDVerRemote | read-only | current | Remote FRM220-F100M Series card CPLD version x.xxx |
| 1.3.6.1.4.1.4756.20.311.20.1.6 | Columnf100mCardFPGAVerRemote | read-only | current | Remote FRM220-F100M Series card FPGA version x.xxx |
| 1.3.6.1.4.1.4756.20.311.20.1.7 | Columnf100mSettoDefaultRemote | read-write | current | Remote FRM220-F100M Series card set to default: 0:OFF 1:Action |
| 1.3.6.1.4.1.4756.20.311.20.1.8 | Columnf100mPortResetRemote | read-write | current | Remote FRM220-F100M Series card portreset: 0:OFF 1:Action |
| 1.3.6.1.4.1.4756.20.311.20.1.9 | Columnf100mModelRemote | read-only | current | Remote FRM220-F100/1000MS Card Type: 0:100M 1:100MS 2:1000M 3:1000MS 4:FMC-100M 5:FMC-100MS 6:FMC-1000M 7:FMC-1000MS 8:FTH4-100M 9:FTH4-100MS 10:FTH4-1000M 11:… |
| 1.3.6.1.4.1.4756.20.311.20.1.10 | Columnf100mFxLinkRemote | read-only | current | Remote FRM220-F100M fiber link status: 0:Down 1:up |
| 1.3.6.1.4.1.4756.20.311.20.1.11 | Columnf100mFxNegoRemote | read-write | current | Remote FRM220-F100M fiber negotiation: 0:Manual 1:Auto |
| 1.3.6.1.4.1.4756.20.311.20.1.12 | Columnf100mFxSpeedRemote | read-write | current | Remote FRM220-F100M fiber speed: 0:100M 1:1000M |
| 1.3.6.1.4.1.4756.20.311.20.1.13 | Columnf100mFxSpeedSTSRemote | read-only | current | Remote FRM220-F100M loopback mode: 0:100M 1:1000M |
| 1.3.6.1.4.1.4756.20.311.20.1.14 | Columnf100mFxManagementRemote | read-write | current | Remote FRM220-F100M fiber management: 0:Disalbe 1:Enable |
| 1.3.6.1.4.1.4756.20.311.20.1.15 | Columnf100mFxFlowCnlSRemote | read-write | current | Remote FRM220-F100M fiber flow control: 0:Disalbe 1:Enable |
| 1.3.6.1.4.1.4756.20.311.20.1.16 | Columnf100mFxIRLimiteRemote | read-write | current | Remote FRM220-F100M fiber IRL limit: 0:Disalbe 1:Enable |
| 1.3.6.1.4.1.4756.20.311.20.1.17 | Columnf100mFxIRLRemote | read-write | current | Remote FRM220-F100M fiber IRL index N * 64K |
| 1.3.6.1.4.1.4756.20.311.20.1.18 | Columnf100mFxERLimiteRemote | read-write | current | Remote FRM220-F100M fiber ERL limit: 0:Disalbe 1:Enable |
| 1.3.6.1.4.1.4756.20.311.20.1.19 | Columnf100mFxERLRemote | read-write | current | Remote FRM220-F100M fiber ERL index N * 64K |
| 1.3.6.1.4.1.4756.20.311.20.1.20 | Columnf100mUtpActiveRemote | read-write | current | Remote FRM220-F100M UTP active: 0:Disable 1:Enable |
| 1.3.6.1.4.1.4756.20.311.20.1.21 | Columnf100mUtpLinkRemote | read-only | current | Remote FRM220-F100M UTP link: 0:Down 1:Up |
| 1.3.6.1.4.1.4756.20.311.20.1.22 | Columnf100mUtpNegoRemote | read-write | current | Remote FRM220-F100M UTP negotiation: 0:Manual 1:Auto |
| 1.3.6.1.4.1.4756.20.311.20.1.23 | Columnf100mUtpSpeedRemote | read-write | current | Remote FRM220-F100M UTP speed: 0:10M 1:100M 2:1000M |
| 1.3.6.1.4.1.4756.20.311.20.1.24 | Columnf100mUtpDuplexRemote | read-write | current | Remote FRM220-F100M UTP duplex: 0:Half 1:Full |
| 1.3.6.1.4.1.4756.20.311.20.1.25 | Columnf100mUtpSpeedSTSRemote | read-only | current | Remote FRM220-F100M UTP speed status: 0:10M 1:100M 2:1000M |
| 1.3.6.1.4.1.4756.20.311.20.1.26 | Columnf100mUtpDuplexSTSRemote | read-only | current | Remote FRM220-F100M UTP duplex status: 0:Half 1:Full |
| 1.3.6.1.4.1.4756.20.311.20.1.27 | Columnf100mUtpFlowCnlRemote | read-write | current | Remote FRM220-F100M UTP flow control: 0:Disable 1:Enable |
| 1.3.6.1.4.1.4756.20.311.20.1.28 | Columnf100mUtpIRLimiteRemote | read-write | current | Remote FRM220-F100M UTP IRL limit: 0:Disable 1:Enable |
| 1.3.6.1.4.1.4756.20.311.20.1.29 | Columnf100mUtpIRLRemote | read-write | current | Remote FRM220-F100M UTP IRL index N * 64K |
| 1.3.6.1.4.1.4756.20.311.20.1.30 | Columnf100mUtpERLimiteRemote | read-write | current | Remote FRM220-F100M UTP ERL limit: 0:Disable 1:Enable |
| 1.3.6.1.4.1.4756.20.311.20.1.31 | Columnf100mUtpERLRemote | read-write | current | Remote FRM220-F100M UTP ERL index N * 64K |
| 1.3.6.1.4.1.4756.20.311.20.1.32 | Columnf100mIpAddrRemote | read-write | current | Remote FRM220-F100M IP address |
| 1.3.6.1.4.1.4756.20.311.20.1.33 | Columnf100mNetmaskRemote | read-write | current | Remote FRM220-F100M Netmask |
| 1.3.6.1.4.1.4756.20.311.20.1.34 | Columnf100mGatewayRemote | read-write | current | Remote FRM220-F100M Gateway |
| 1.3.6.1.4.1.4756.20.311.20.1.35 | Columnf100mAlsModeRemote | read-write | current | Remote FRM220-F100M Auto Laser Shut Down: 0:Disable 1:Enable |
| 1.3.6.1.4.1.4756.20.311.20.1.36 | Columnf100mLfpModeRemote | read-write | current | Remote FRM220-F100M Link fault pass through: 0:Disable 1:Enable |
| 1.3.6.1.4.1.4756.20.311.20.1.37 | Columnf100mDHCPRemote | read-write | current | Remote FRM220-F100M DHCP: 0:Disable 1:Enable |
| 1.3.6.1.4.1.4756.20.311.20.1.38 | Columnf100mRemotePWRRemote | read-only | current | Remote FRM220-F100M remote power: 0:Ok 1:Abnormal |
| 1.3.6.1.4.1.4756.20.311.20.1.39 | Columnf100mJumboFrameRemote | read-write | current | Remote FRM220-F100M jumbo frame: 0:Disable 1:Enable |
| 1.3.6.1.4.1.4756.20.311.20.1.40 | Columnf100mCrcRemote | read-write | current | Remote FRM220-F100M crc: 0:OFF 1:ON |
| 1.3.6.1.4.1.4756.20.311.20.1.41 | Columnf100mPauseFrameRemote | read-write | current | Remote FRM220-F100M pause frame: 0:Disable 1:Enable |
| 1.3.6.1.4.1.4756.20.311.20.1.42 | Columnf100mQosRemote | read-write | current | Remote FRM220-F100M pause frame: 0:Disable 1:Enable |
| 1.3.6.1.4.1.4756.20.311.20.1.43 | Columnf100mBsFilterRemote | read-write | current | Remote FRM220-F100M Brosdcast Storm Filter : 0:Disable 1:Enalbe |
| 1.3.6.1.4.1.4756.20.311.20.1.44 | Columnf100mMsFilterRemote | read-write | current | Remote FRM220-F100M Multicast Storm Filter: 0:Disable 1:Enable |
| 1.3.6.1.4.1.4756.20.311.20.1.45 | Columnf100mUnDaFilterRemote | read-write | current | Remote FRM220-F100M Unknown DA Unicast Storm Filter: 0:Disable 1:Enable |
| 1.3.6.1.4.1.4756.20.311.20.1.46 | Columnf100mTpVLANNBRemote | read-write | current | Remote FRM220-F100M Tp VLAN number: |
| 1.3.6.1.4.1.4756.20.311.20.1.47 | Columnf100mTpFrameGressRemote | read-write | current | Remote FRM220-F100M TP Frame Egress Type: 0:Replace Tag 1:Remove Tag 2:Add Tag 3:Don't Touch Tag |
| 1.3.6.1.4.1.4756.20.311.20.1.48 | Columnf100mFxVLANNBRemote | read-write | current | Remote FRM220-F100M Fx VLAN number: |
| 1.3.6.1.4.1.4756.20.311.20.1.49 | Columnf100mFxFrameGressRemote | read-write | current | Remote FRM220-F100M Fx Frame Egress Type: 0:Replace Tag 1:Remove Tag 2:Add Tag 3:Don't Touch Tag |
| 1.3.6.1.4.1.4756.20.311.20.1.50 | Columnf100mCpuVLANNBRemote | read-write | current | Remote FRM220-F100M Cpu VLAN number: |
| 1.3.6.1.4.1.4756.20.311.20.1.51 | Columnf100mCpuFrameGressRemote | read-write | current | Remote FRM220-F100M Cpu Frame Egress Type: 0:Replace Tag 1:Remove Tag 2:Add Tag 3:Don't Touch Tag |
| 1.3.6.1.4.1.4756.20.311.20.1.52 | Columnf100mVLANGpRemote | read-write | current | Remote FRM220-F100M VLAN Group : 0:Disable 1:Enalbe |
| 1.3.6.1.4.1.4756.20.311.20.1.53 | Columnf100mTpMember0Remote | read-write | current | Remote FRM220-F100M Tp Member 0: 0:Disalbe 1:Enable |
| 1.3.6.1.4.1.4756.20.311.20.1.54 | Columnf100mTpMember1Remote | read-write | current | Remote FRM220-F100M Tp Member 1: 0:Disalbe 1:Enable |
| 1.3.6.1.4.1.4756.20.311.20.1.55 | Columnf100mTpMember2Remote | read-write | current | Remote FRM220-F100M Tp Member 2: 0:Disalbe 1:Enable |
| 1.3.6.1.4.1.4756.20.311.20.1.56 | Columnf100mTpMember3Remote | read-write | current | Remote FRM220-F100M Tp Member 3: 0:Disalbe 1:Enable |
| 1.3.6.1.4.1.4756.20.311.20.1.57 | Columnf100mTpMember4Remote | read-write | current | Remote FRM220-F100M Tp Member 4: 0:Disalbe 1:Enable |
| 1.3.6.1.4.1.4756.20.311.20.1.58 | Columnf100mTpMember5Remote | read-write | current | Remote FRM220-F100M Tp Member 5: 0:Disalbe 1:Enable |
| 1.3.6.1.4.1.4756.20.311.20.1.59 | Columnf100mTpMember6Remote | read-write | current | Remote FRM220-F100M Tp Member 6: 0:Disalbe 1:Enable |
| 1.3.6.1.4.1.4756.20.311.20.1.60 | Columnf100mTpMember7Remote | read-write | current | Remote FRM220-F100M Tp Member 7: 0:Disalbe 1:Enable |
| 1.3.6.1.4.1.4756.20.311.20.1.61 | Columnf100mTpMember8Remote | read-write | current | Remote FRM220-F100M Tp Member 8: 0:Disalbe 1:Enable |
| 1.3.6.1.4.1.4756.20.311.20.1.62 | Columnf100mTpMember9Remote | read-write | current | Remote FRM220-F100M Tp Member 9: 0:Disalbe 1:Enable |
| 1.3.6.1.4.1.4756.20.311.20.1.63 | Columnf100mTpMember10Remote | read-write | current | Remote FRM220-F100M Tp Member 10: 0:Disalbe 1:Enable |
| 1.3.6.1.4.1.4756.20.311.20.1.64 | Columnf100mTpMember11Remote | read-write | current | Remote FRM220-F100M Tp Member 11: 0:Disalbe 1:Enable |
| 1.3.6.1.4.1.4756.20.311.20.1.65 | Columnf100mTpMember12Remote | read-write | current | Remote FRM220-F100M Tp Member 12: 0:Disalbe 1:Enable |
| 1.3.6.1.4.1.4756.20.311.20.1.66 | Columnf100mTpMember13Remote | read-write | current | Remote FRM220-F100M Tp Member 13: 0:Disalbe 1:Enable |
| 1.3.6.1.4.1.4756.20.311.20.1.67 | Columnf100mTpMember14Remote | read-write | current | Remote FRM220-F100M Tp Member 14: 0:Disalbe 1:Enable |
| 1.3.6.1.4.1.4756.20.311.20.1.68 | Columnf100mTpMember15Remote | read-write | current | Remote FRM220-F100M Tp Member 15: 0:Disalbe 1:Enable |
| 1.3.6.1.4.1.4756.20.311.20.1.69 | Columnf100mFxMember0Remote | read-write | current | Remote FRM220-F100M Fx Member 0: 0:Disalbe 1:Enable |
| 1.3.6.1.4.1.4756.20.311.20.1.70 | Columnf100mFxMember1Remote | read-write | current | Remote FRM220-F100M Fx Member 1: 0:Disalbe 1:Enable |
| 1.3.6.1.4.1.4756.20.311.20.1.71 | Columnf100mFxMember2Remote | read-write | current | Remote FRM220-F100M Fx Member 2: 0:Disalbe 1:Enable |
| 1.3.6.1.4.1.4756.20.311.20.1.72 | Columnf100mFxMember3Remote | read-write | current | Remote FRM220-F100M Fx Member 3: 0:Disalbe 1:Enable |
| 1.3.6.1.4.1.4756.20.311.20.1.73 | Columnf100mFxMember4Remote | read-write | current | Remote FRM220-F100M Fx Member 4: 0:Disalbe 1:Enable |
| 1.3.6.1.4.1.4756.20.311.20.1.74 | Columnf100mFxMember5Remote | read-write | current | Remote FRM220-F100M Fx Member 5: 0:Disalbe 1:Enable |
| 1.3.6.1.4.1.4756.20.311.20.1.75 | Columnf100mFxMember6Remote | read-write | current | Remote FRM220-F100M Fx Member 6: 0:Disalbe 1:Enable |
| 1.3.6.1.4.1.4756.20.311.20.1.76 | Columnf100mFxMember7Remote | read-write | current | Remote FRM220-F100M Fx Member 7: 0:Disalbe 1:Enable |
| 1.3.6.1.4.1.4756.20.311.20.1.77 | Columnf100mFxMember8Remote | read-write | current | Remote FRM220-F100M Fx Member 8: 0:Disalbe 1:Enable |
| 1.3.6.1.4.1.4756.20.311.20.1.78 | Columnf100mFxMember9Remote | read-write | current | Remote FRM220-F100M Fx Member 9: 0:Disalbe 1:Enable |
| 1.3.6.1.4.1.4756.20.311.20.1.79 | Columnf100mFxMember10Remote | read-write | current | Remote FRM220-F100M Fx Member 10: 0:Disalbe 1:Enable |
| 1.3.6.1.4.1.4756.20.311.20.1.80 | Columnf100mFxMember11Remote | read-write | current | Remote FRM220-F100M Fx Member 11: 0:Disalbe 1:Enable |
| 1.3.6.1.4.1.4756.20.311.20.1.81 | Columnf100mFxMember12Remote | read-write | current | Remote FRM220-F100M Fx Member 12: 0:Disalbe 1:Enable |
| 1.3.6.1.4.1.4756.20.311.20.1.82 | Columnf100mFxMember13Remote | read-write | current | Remote FRM220-F100M Fx Member 13: 0:Disalbe 1:Enable |
| 1.3.6.1.4.1.4756.20.311.20.1.83 | Columnf100mFxMember14Remote | read-write | current | Remote FRM220-F100M Fx Member 14: 0:Disalbe 1:Enable |
| 1.3.6.1.4.1.4756.20.311.20.1.84 | Columnf100mFxMember15Remote | read-write | current | Remote FRM220-F100M Fx Member 15: 0:Disalbe 1:Enable |
| 1.3.6.1.4.1.4756.20.311.20.1.85 | Columnf100mCpuMember0Remote | read-write | current | Remote FRM220-F100M Cpu Member 0: 0:Disalbe 1:Enable |
| 1.3.6.1.4.1.4756.20.311.20.1.86 | Columnf100mCpuMember1Remote | read-write | current | Remote FRM220-F100M Cpu Member 1: 0:Disalbe 1:Enable |
| 1.3.6.1.4.1.4756.20.311.20.1.87 | Columnf100mCpuMember2Remote | read-write | current | Remote FRM220-F100M Cpu Member 2: 0:Disalbe 1:Enable |
| 1.3.6.1.4.1.4756.20.311.20.1.88 | Columnf100mCpuMember3Remote | read-write | current | Remote FRM220-F100M Cpu Member 3: 0:Disalbe 1:Enable |
| 1.3.6.1.4.1.4756.20.311.20.1.89 | Columnf100mCpuMember4Remote | read-write | current | Remote FRM220-F100M Cpu Member 4: 0:Disalbe 1:Enable |
| 1.3.6.1.4.1.4756.20.311.20.1.90 | Columnf100mCpuMember5Remote | read-write | current | Remote FRM220-F100M Cpu Member 5: 0:Disalbe 1:Enable |
| 1.3.6.1.4.1.4756.20.311.20.1.91 | Columnf100mCpuMember6Remote | read-write | current | Remote FRM220-F100M Cpu Member 6: 0:Disalbe 1:Enable |
| 1.3.6.1.4.1.4756.20.311.20.1.92 | Columnf100mCpuMember7Remote | read-write | current | Remote FRM220-F100M Cpu Member 7: 0:Disalbe 1:Enable |
| 1.3.6.1.4.1.4756.20.311.20.1.93 | Columnf100mCpuMember8Remote | read-write | current | Remote FRM220-F100M Cpu Member 8: 0:Disalbe 1:Enable |
| 1.3.6.1.4.1.4756.20.311.20.1.94 | Columnf100mCpuMember9Remote | read-write | current | Remote FRM220-F100M Cpu Member 9: 0:Disalbe 1:Enable |
| 1.3.6.1.4.1.4756.20.311.20.1.95 | Columnf100mCpuMember10Remote | read-write | current | Remote FRM220-F100M Cpu Member 10: 0:Disalbe 1:Enable |
| 1.3.6.1.4.1.4756.20.311.20.1.96 | Columnf100mCpuMember11Remote | read-write | current | Remote FRM220-F100M Cpu Member 11: 0:Disalbe 1:Enable |
| 1.3.6.1.4.1.4756.20.311.20.1.97 | Columnf100mCpuMember12Remote | read-write | current | Remote FRM220-F100M Cpu Member 12: 0:Disalbe 1:Enable |
| 1.3.6.1.4.1.4756.20.311.20.1.98 | Columnf100mCpuMember13Remote | read-write | current | Remote FRM220-F100M Cpu Member 13: 0:Disalbe 1:Enable |
| 1.3.6.1.4.1.4756.20.311.20.1.99 | Columnf100mCpuMember14Remote | read-write | current | Remote FRM220-F100M Cpu Member 14: 0:Disalbe 1:Enable |
| 1.3.6.1.4.1.4756.20.311.20.1.100 | Columnf100mCpuMember15Remote | read-write | current | Remote FRM220-F100M Cpu Member 15: 0:Disalbe 1:Enable |
| 1.3.6.1.4.1.4756.20.311.20.1.101 | Columnf100mPVID0Remote | read-write | current | Remote FRM220-F100M Port 0 VID : |
| 1.3.6.1.4.1.4756.20.311.20.1.102 | Columnf100mPVID1Remote | read-write | current | Remote FRM220-F100M Port 1 VID : |
| 1.3.6.1.4.1.4756.20.311.20.1.103 | Columnf100mPVID2Remote | read-write | current | Remote FRM220-F100M Port 2 VID : |
| 1.3.6.1.4.1.4756.20.311.20.1.104 | Columnf100mPVID3Remote | read-write | current | Remote FRM220-F100M Port 3 VID : |
| 1.3.6.1.4.1.4756.20.311.20.1.105 | Columnf100mPVID4Remote | read-write | current | Remote FRM220-F100M Port 4 VID : |
| 1.3.6.1.4.1.4756.20.311.20.1.106 | Columnf100mPVID5Remote | read-write | current | Remote FRM220-F100M Port 5 VID : |
| 1.3.6.1.4.1.4756.20.311.20.1.107 | Columnf100mPVID6Remote | read-write | current | Remote FRM220-F100M Port 6 VID : |
| 1.3.6.1.4.1.4756.20.311.20.1.108 | Columnf100mPVID7Remote | read-write | current | Remote FRM220-F100M Port 7 VID : |
| 1.3.6.1.4.1.4756.20.311.20.1.109 | Columnf100mPVID8Remote | read-write | current | Remote FRM220-F100M Port 8 VID : |
| 1.3.6.1.4.1.4756.20.311.20.1.110 | Columnf100mPVID9Remote | read-write | current | Remote FRM220-F100M Port 9 VID : |
| 1.3.6.1.4.1.4756.20.311.20.1.111 | Columnf100mPVID10Remote | read-write | current | Remote FRM220-F100M Port 10 VID : |
| 1.3.6.1.4.1.4756.20.311.20.1.112 | Columnf100mPVID11Remote | read-write | current | Remote FRM220-F100M Port 11 VID : |
| 1.3.6.1.4.1.4756.20.311.20.1.113 | Columnf100mPVID12Remote | read-write | current | Remote FRM220-F100M Port 12 VID : |
| 1.3.6.1.4.1.4756.20.311.20.1.114 | Columnf100mPVID13Remote | read-write | current | Remote FRM220-F100M Port 13 VID : |
| 1.3.6.1.4.1.4756.20.311.20.1.115 | Columnf100mPVID14Remote | read-write | current | Remote FRM220-F100M Port 14 VID : |
| 1.3.6.1.4.1.4756.20.311.20.1.116 | Columnf100mPVID15Remote | read-write | current | Remote FRM220-F100M Port 15 VID : |
| 1.3.6.1.4.1.4756.20.311.20.1.117 | Columnf100mDoubleVLANRemote | read-write | current | Remote FRM220-F100M Double VLAN: 0:Disable 1:Enable |
| 1.3.6.1.4.1.4756.20.311.20.1.118 | Columnf100mDoubleVLANTagPriorityRemote | read-write | current | Remote FRM220-F100M Double VLAN Tag Priority : 0:Internal 1:Remark |
| 1.3.6.1.4.1.4756.20.311.20.1.119 | Columnf100mDoubleVLANDirectionRemote | read-write | current | Remote FRM220-F100M Double VLAN Direction : 0:TP add,FX Remove 1:FX add,TP Remove |
| 1.3.6.1.4.1.4756.20.311.20.1.120 | Columnf100mDoubleVLANTagTypeRemote | read-only | current | Remote FRM220-F100M Tag Type (HEX) : |
| 1.3.6.1.4.1.4756.20.311.20.1.121 | Columnf100mDoubleVLANVIDRemote | read-write | current | Remote FRM220-F100M Double VLAN VID : |
| 1.3.6.1.4.1.4756.20.311.20.1.122 | Columnf100mFxDDRemote | read-only | current | Remote device card fiber Digital Diagnostic function: 0:No 1:Yes |
| 1.3.6.1.4.1.4756.20.311.20.1.123 | Columnf100mDDVendorRemote | read-only | current | Remote device card fiber D/D information: Vendor name |
| 1.3.6.1.4.1.4756.20.311.20.1.124 | Columnf100mDDPartNoRemote | read-only | current | Remote device card fiber D/D information: Vendor part number |
| 1.3.6.1.4.1.4756.20.311.20.1.125 | Columnf100mDDFiberTypeRemote | read-only | current | Remote device card fiber D/D information: Fiber Type |
| 1.3.6.1.4.1.4756.20.311.20.1.126 | Columnf100mDDWaveLenRemote | read-only | current | Remote device card fiber D/D information: Wave length |
| 1.3.6.1.4.1.4756.20.311.20.1.127 | Columnf100mDDWaveLen2Remote | read-only | current | Remote device card fiber D/D information: Wave length 2 |
| 1.3.6.1.4.1.4756.20.311.20.1.128 | Columnf100mDDLinkLenRemote | read-only | current | Remote device card fiber D/D information: Link length |
| 1.3.6.1.4.1.4756.20.311.20.1.129 | Columnf100mDDLenUnitRemote | read-only | current | Remote device card fiber D/D information: Length Unit |
| 1.3.6.1.4.1.4756.20.311.20.1.130 | Columnf100mDDStatusRemote | read-only | current | Remote device card fiber D/D information: Status Support |
| 1.3.6.1.4.1.4756.20.311.20.1.131 | Columnf100mDDRxSensRemote | read-only | current | Remote device card fiber D/D information: Rx Sensitivity |
| 1.3.6.1.4.1.4756.20.311.20.1.132 | Columnf100mDDTxPWRRemote | read-only | current | Remote device card fiber D/D information: Tx power |
| 1.3.6.1.4.1.4756.20.311.20.1.133 | Columnf100mDDRxPWRRemote | read-only | current | Remote device card fiber D/D information: Rx power |
| 1.3.6.1.4.1.4756.20.311.20.1.134 | Columnf100mDDTempRemote | read-only | current | Remote device card fiber D/D information: Temperature in degree C |
| 1.3.6.1.4.1.4756.20.311.20.1.135 | Columnf100mDDPWRMarginRemote | read-only | current | Remote device card fiber D/D information: Power margin |
| 1.3.6.1.4.1.4756.20.311.20.1.136 | Columnf100mLBStartRemote | read-write | current | Remote device card Loop back test : 1:Off 2:Action |
| 1.3.6.1.4.1.4756.20.311.20.1.137 | Columnf100mLBStartStatusRemote | read-only | current | Remote device card Loop back test status : 1:Normal 2:Ok 3:Fail |
| 1.3.6.1.4.1.4756.20.311.20.1.138 | Columnf100mPower1StatusRemote | read-only | current | Remote device card Power1 status (IMC series card only) |
| 1.3.6.1.4.1.4756.20.311.20.1.139 | Columnf100mPower2StatusRemote | read-only | current | Remote device card Power2 status (IMC series card only) |
| 1.3.6.1.4.1.4756.20.311.20.1.140 | Columnf100mFaultStatusRemote | read-only | current | Remote device card Fault status (IMC series card only) |
| 1.3.6.1.4.1.4756.20.311.20.1.141 | Columnf100mPowerLossRemote | read-write | current | Remote device card Power Loss Alarm(IMC series card only) |
| 1.3.6.1.4.1.4756.20.311.20.1.142 | Columnf100mTPLossRemote | read-write | current | Remote device card TP Loss Alarm(IMC series card only) |
| 1.3.6.1.4.1.4756.20.311.20.1.143 | Columnf100mFXLossRemote | read-write | current | Remote device card FX Loss Alarm(IMC series card only) |
| 1.3.6.1.4.1.4756.20.311.20.1.144 | Columnf100mPoEModeRemote | read-write | current | Remote device card PoE Mode(IMC-100/1000M(S)-PH12 series card only) |
| 1.3.6.1.4.1.4756.20.311.20.1.145 | Columnf100mPowerAllocationLimitRemote | read-write | current | Remote device card Power Allocation Limit [W](IMC-100/1000M(S)-PH12 series card only) 1: 5 W 2: 10 W 3: 15 W 4: 20 W 5: 25 W 6: 30 W |
| 1.3.6.1.4.1.4756.20.311.20.1.146 | Columnf100mPDClassRemote | read-only | current | Remote device card PD Class(IMC-100/1000M(S)-PH12 series card only) |
| 1.3.6.1.4.1.4756.20.311.20.1.147 | Columnf100mPowerRequestedRemote | read-only | current | Remote device card Power Requested(IMC-100/1000M(S)-PH12 series card only) |
| 1.3.6.1.4.1.4756.20.311.20.1.148 | Columnf100mPowerUsedRemote | read-only | current | Remote device card Power Used(IMC-100/1000M(S)-PH12 series card only) |
| 1.3.6.1.4.1.4756.20.311.20.1.149 | Columnf100mDetectionRemote | read-only | current | Remote device card Power Used(IMC-100/1000M(S)-PH12 series card only) |
| 1.3.6.1.4.1.4756.20.320 | Nodefom01LocalCards | |||
| 1.3.6.1.4.1.4756.20.320.20 | Tablefom01LocalTable | not-accessible | current | A list of local FRM220-FOM01 series card entries. The number of entries is fom01-No-L. |
| 1.3.6.1.4.1.4756.20.320.20.1 | Rowfom01LocalEntry | not-accessible | current | An entry containing management information applicable to a particular local FRM220-FOM01 series card. |
| 1.3.6.1.4.1.4756.20.320.20.1.1 | Columnfom01ChassisIndexLocal | read-only | current | A unique value for each local card. It is the chassis location number. |
| 1.3.6.1.4.1.4756.20.320.20.1.2 | Columnfom01SlotIndexLocal | read-only | current | A unique value for each local card. It is the slot location number. |
| 1.3.6.1.4.1.4756.20.320.20.1.3 | Columnfom01CardHWVerLocal | read-only | current | Local FRM220-FOM01 Series card hardware version x.xxx |
| 1.3.6.1.4.1.4756.20.320.20.1.4 | Columnfom01CardFWVerLocal | read-only | current | Local FRM220-FOM01 Series card firmware version x.xxx |
| 1.3.6.1.4.1.4756.20.320.20.1.5 | Columnfom01CardCPLDVerLocal | read-only | current | Local FRM220-FOM01 Series card CPLD version x.xxx |
| 1.3.6.1.4.1.4756.20.320.20.1.6 | Columnfom01CardFPGAVerLocal | read-only | current | Local FRM220-FOM01 Series card FPGA version x.xxx |
| 1.3.6.1.4.1.4756.20.320.20.1.7 | Columnfom01PortActiveLocal | read-write | current | Local FRM220-FOM01 Series card active: 0:Disable 1:Enable |
| 1.3.6.1.4.1.4756.20.320.20.1.8 | Columnfom01SettoDefaultLocal | read-write | current | Local FRM220-FOM01 Series card set to default: 0:OFF 1:Action |
| 1.3.6.1.4.1.4756.20.320.20.1.9 | Columnfom01PortResetLocal | read-write | current | Local FRM220-FOM01 Series card portreset: 0:OFF 1:Action |
| 1.3.6.1.4.1.4756.20.320.20.1.10 | Columnfom01FxLinkLocal | read-only | current | Local FRM220-FOM01 fiber link status: 0:Down 1:up |
| 1.3.6.1.4.1.4756.20.320.20.1.11 | Columnfom01FxRxActiveLocal | read-only | current | Local FRM220-FOM01 fiber Rx Active: 0:Down 1:up |
| 1.3.6.1.4.1.4756.20.320.20.1.12 | Columnfom01FxLBSettingLocal | read-write | current | Local FRM220-FOM01 fiber loop back: 0:Disable 1:LLB 2:RLB |
| 1.3.6.1.4.1.4756.20.320.20.1.13 | Columnfom01LfpModeLocal | read-write | current | Local FRM220-FOM01 link fault pass throught: 0:Disable 1:Enable |
| 1.3.6.1.4.1.4756.20.320.20.1.14 | Columnfom01RemotePWRLocal | read-only | current | Local FRM220-FOM01 remote power fail: 0:Ok 1:Abnormal |
| 1.3.6.1.4.1.4756.20.320.20.1.15 | Columnfom01E1T1TermLocal | read-write | current | Local FRM220-FOM01 E1/T1 Termination: 0:E1/75/BNC 1:E1/120/RJ45 2:T1/100/RJ45 |
| 1.3.6.1.4.1.4756.20.320.20.1.16 | Columnfom01E1T1ActiveLocal | read-write | current | Local FRM220-FOM01 E1/T1 active: 0:Disable 1:Enable |
| 1.3.6.1.4.1.4756.20.320.20.1.17 | Columnfom01E1T1LinkLocal | read-only | current | Local FRM220-FOM01 E1/T1 link: 0:Down 1:Up |
| 1.3.6.1.4.1.4756.20.320.20.1.18 | Columnfom01E1T1BVPErrorLocal | read-only | current | Local FRM220-FOM01 E1/T1 BVP error: 0:Normal 1:Error |
| 1.3.6.1.4.1.4756.20.320.20.1.19 | Columnfom01E1T1LineCodeLocal | read-write | current | Local FRM220-FOM01 E1/T1 line code: 0:HDB3/B8ZS 1:AMI |
| 1.3.6.1.4.1.4756.20.320.20.1.20 | Columnfom01E1T1LBSettingLocal | read-write | current | Local FRM220-FOM01 E1/T1 loop back: 0:Disable 1:LLB 2:RLB |
| 1.3.6.1.4.1.4756.20.320.20.1.21 | Columnfom01UtpActiveLocal | read-write | current | Local FRM220-FOM01 UTP active: 0:Disable 1:Enable |
| 1.3.6.1.4.1.4756.20.320.20.1.22 | Columnfom01UtpLinkLocal | read-only | current | Local FRM220-FOM01 UTP link status: 0:Down 1:Up |
| 1.3.6.1.4.1.4756.20.320.20.1.23 | Columnfom01UtpNegoLocal | read-write | current | Local FRM220-FOM01 UTP negoiation: 0:Manual 1:Auto |
| 1.3.6.1.4.1.4756.20.320.20.1.24 | Columnfom01UtpSpeedLocal | read-write | current | Local FRM220-FOM01 UTP speed: 0:On 1:Off |
| 1.3.6.1.4.1.4756.20.320.20.1.25 | Columnfom01UtpDuplexLocal | read-write | current | Local FRM220-FOM01 UTP duplex: 0:Half 1:Full |
| 1.3.6.1.4.1.4756.20.320.20.1.26 | Columnfom01UtpDuplexSTSLocal | read-only | current | Local FRM220-FOM01 UTP Duplex status: 0:Half 1:Full |
| 1.3.6.1.4.1.4756.20.320.20.1.27 | Columnfom01UtpSpeedSTSLocal | read-only | current | Local FRM220-FOM01 UTP speed status: 0:10M 1:100M |
| 1.3.6.1.4.1.4756.20.320.20.1.28 | Columnfom01FxDDLocal | read-only | current | Local device card fiber port Digital Diagnostic function: 0:No 1:Yes |
| 1.3.6.1.4.1.4756.20.320.20.1.29 | Columnfom01DDVendorLocal | read-only | current | Local device card fiber port D/D information: Vendor name |
| 1.3.6.1.4.1.4756.20.320.20.1.30 | Columnfom01DDPartNoLocal | read-only | current | Local device card fiber port D/D information: Vendor part number |
| 1.3.6.1.4.1.4756.20.320.20.1.31 | Columnfom01DDFiberTypeLocal | read-only | current | Local device card fiber port D/D information: Fiber Type |
| 1.3.6.1.4.1.4756.20.320.20.1.32 | Columnfom01DDWaveLenLocal | read-only | current | Local device card fiber port D/D information: Wave length |
| 1.3.6.1.4.1.4756.20.320.20.1.33 | Columnfom01DDWaveLen2Local | read-only | current | Local device card fiber port D/D information: Wave length 2 |
| 1.3.6.1.4.1.4756.20.320.20.1.34 | Columnfom01DDLinkLenLocal | read-only | current | Local device card fiber port D/D information: Link length |
| 1.3.6.1.4.1.4756.20.320.20.1.35 | Columnfom01DDLenUnitLocal | read-only | current | Local device card fiber port D/D information: Length Unit |
| 1.3.6.1.4.1.4756.20.320.20.1.36 | Columnfom01DDStatusLocal | read-only | current | Local device card fiber port D/D information: Status Support |
| 1.3.6.1.4.1.4756.20.320.20.1.37 | Columnfom01DDRxSensLocal | read-only | current | Local device card fiber port D/D information: Rx Sensitivity |
| 1.3.6.1.4.1.4756.20.320.20.1.38 | Columnfom01DDTxPWRLocal | read-only | current | Local device card fiber port D/D information: Tx power |
| 1.3.6.1.4.1.4756.20.320.20.1.39 | Columnfom01DDRxPWRLocal | read-only | current | Local device card fiber port D/D information: Rx power |
| 1.3.6.1.4.1.4756.20.320.20.1.40 | Columnfom01DDTempLocal | read-only | current | Local device card fiber port D/D information: Temperature in degree C |
| 1.3.6.1.4.1.4756.20.320.20.1.41 | Columnfom01DDPWRMarginLocal | read-only | current | Local device card fiber port D/D information: Power margin |
| 1.3.6.1.4.1.4756.20.320.20.1.42 | Columnfom01FxFEFLocal | read-only | current | Local device card fiber detected Far End Fault: 0:Undetect 1:Detected |
| 1.3.6.1.4.1.4756.20.321 | Nodefom01RemoteCards | |||
| 1.3.6.1.4.1.4756.20.321.20 | Tablefom01RemoteTable | not-accessible | current | A list of local FRM220-FOM01 series card entries. The number of entries is fom01-No-R. |
| 1.3.6.1.4.1.4756.20.321.20.1 | Rowfom01RemoteEntry | not-accessible | current | An entry containing management information applicable to a particular local FRM220-FOM01 series card. |
| 1.3.6.1.4.1.4756.20.321.20.1.1 | Columnfom01ChassisIndexRemote | read-only | current | A unique value for each local card. It is the chassis location number. |
| 1.3.6.1.4.1.4756.20.321.20.1.2 | Columnfom01SlotIndexRemote | read-only | current | A unique value for each local card. It is the slot location number. |
| 1.3.6.1.4.1.4756.20.321.20.1.3 | Columnfom01CardHWVerRemote | read-only | current | Remote FRM220-FOM01 Series card hardware version x.xxx |
| 1.3.6.1.4.1.4756.20.321.20.1.4 | Columnfom01CardFWVerRemote | read-only | current | Remote FRM220-FOM01 Series card firmware version x.xxx |
| 1.3.6.1.4.1.4756.20.321.20.1.5 | Columnfom01CardCPLDVerRemote | read-only | current | Remote FRM220-FOM01 Series card CPLD version x.xxx |
| 1.3.6.1.4.1.4756.20.321.20.1.6 | Columnfom01CardFPGAVerRemote | read-only | current | Remote FRM220-FOM01 Series card FPGA version x.xxx |
| 1.3.6.1.4.1.4756.20.321.20.1.7 | Columnfom01SettoDefaultRemote | read-write | current | Remote FRM220-FOM01 Series card set to default: 0:OFF 1:Action |
| 1.3.6.1.4.1.4756.20.321.20.1.8 | Columnfom01PortResetRemote | read-write | current | Remote FRM220-FOM01 Series card portreset: 0:OFF 1:Action |
| 1.3.6.1.4.1.4756.20.321.20.1.9 | Columnfom01FxLinkRemote | read-only | current | Remote FRM220-FOM01 fiber link status: 0:Down 1:up |
| 1.3.6.1.4.1.4756.20.321.20.1.10 | Columnfom01FxRxActiveRemote | read-only | current | Remote FRM220-FOM01 fiber Rx Active: 0:Down 1:up |
| 1.3.6.1.4.1.4756.20.321.20.1.11 | Columnfom01FxLBSettingRemote | read-write | current | Remote FRM220-FOM01 fiber loop back: 0:Disable 2:RLB |
| 1.3.6.1.4.1.4756.20.321.20.1.12 | Columnfom01LfpModeRemote | read-write | current | Remote FRM220-FOM01 link fault pass throught: 0:Disable 1:Enable |
| 1.3.6.1.4.1.4756.20.321.20.1.13 | Columnfom01RemotePWRRemote | read-only | current | Remote FRM220-FOM01 remote power fail: 0:Ok 1:Abnormal |
| 1.3.6.1.4.1.4756.20.321.20.1.14 | Columnfom01E1T1TermRemote | read-write | current | Remote FRM220-FOM01 E1/T1 Termination: 0:E1/75/BNC 1:E1/120/RJ45 2:T1/100/RJ45 |
| 1.3.6.1.4.1.4756.20.321.20.1.15 | Columnfom01E1T1ActiveRemote | read-write | current | Remote FRM220-FOM01 E1/T1 active: 0:Disable 1:Enable |
| 1.3.6.1.4.1.4756.20.321.20.1.16 | Columnfom01E1T1LinkRemote | read-only | current | Remote FRM220-FOM01 E1/T1 link: 0:Down 1:Up |
| 1.3.6.1.4.1.4756.20.321.20.1.17 | Columnfom01E1T1BVPErrorRemote | read-only | current | Remote FRM220-FOM01 E1/T1 BVP error: 0:Normal 1:Error |
| 1.3.6.1.4.1.4756.20.321.20.1.18 | Columnfom01E1T1LineCodeRemote | read-write | current | Remote FRM220-FOM01 E1/T1 line code: 0:HDB3/B8ZS 1:AMI |
| 1.3.6.1.4.1.4756.20.321.20.1.19 | Columnfom01E1T1LBSettingRemote | read-write | current | Remote FRM220-FOM01 E1/T1 loop back: 0:Disable 1:LLB 2:RLB |
| 1.3.6.1.4.1.4756.20.321.20.1.20 | Columnfom01UtpActiveRemote | read-write | current | Remote FRM220-FOM01 UTP active: 0:Disable 1:Enable |
| 1.3.6.1.4.1.4756.20.321.20.1.21 | Columnfom01UtpLinkRemote | read-only | current | Remote FRM220-FOM01 UTP link status: 0:Down 1:Up |
| 1.3.6.1.4.1.4756.20.321.20.1.22 | Columnfom01UtpNegoRemote | read-write | current | Remote FRM220-FOM01 UTP negoiation: 0:Manual 1:Auto |
| 1.3.6.1.4.1.4756.20.321.20.1.23 | Columnfom01UtpSpeedRemote | read-write | current | Remote FRM220-FOM01 UTP speed: 0:On 1:Off |
| 1.3.6.1.4.1.4756.20.321.20.1.24 | Columnfom01UtpDuplexRemote | read-write | current | Remote FRM220-FOM01 UTP duplex: 0:Half 1:Full |
| 1.3.6.1.4.1.4756.20.321.20.1.25 | Columnfom01UtpDuplexSTSRemote | read-only | current | Remote FRM220-FOM01 UTP duplex status: 0:Half 1:Full |
| 1.3.6.1.4.1.4756.20.321.20.1.26 | Columnfom01UtpSpeedSTSRemote | read-only | current | Remote FRM220-FOM0 UTP speed status: 0:10M 1:100M |
| 1.3.6.1.4.1.4756.20.321.20.1.27 | Columnfom01FxDDRemote | read-only | current | Remote device card fiber port Digital Diagnostic function: 0:No 1:Yes |
| 1.3.6.1.4.1.4756.20.321.20.1.28 | Columnfom01DDVendorRemote | read-only | current | Remote device card fiber port D/D information: Vendor name |
| 1.3.6.1.4.1.4756.20.321.20.1.29 | Columnfom01DDPartNoRemote | read-only | current | Remote device card fiber port D/D information: Vendor part number |
| 1.3.6.1.4.1.4756.20.321.20.1.30 | Columnfom01DDFiberTypeRemote | read-only | current | Remote device card fiber port D/D information: Fiber Type |
| 1.3.6.1.4.1.4756.20.321.20.1.31 | Columnfom01DDWaveLenRemote | read-only | current | Remote device card fiber port D/D information: Wave length |
| 1.3.6.1.4.1.4756.20.321.20.1.32 | Columnfom01DDWaveLen2Remote | read-only | current | Remote device card fiber port D/D information: Wave length 2 |
| 1.3.6.1.4.1.4756.20.321.20.1.33 | Columnfom01DDLinkLenRemote | read-only | current | Remote device card fiber port D/D information: Link length |
| 1.3.6.1.4.1.4756.20.321.20.1.34 | Columnfom01DDLenUnitRemote | read-only | current | Remote device card fiber port D/D information: Length Unit |
| 1.3.6.1.4.1.4756.20.321.20.1.35 | Columnfom01DDStatusRemote | read-only | current | Remote device card fiber port D/D information: Status Support |
| 1.3.6.1.4.1.4756.20.321.20.1.36 | Columnfom01DDRxSensRemote | read-only | current | Remote device card fiber port D/D information: Rx Sensitivity |
| 1.3.6.1.4.1.4756.20.321.20.1.37 | Columnfom01DDTxPWRRemote | read-only | current | Remote device card fiber port D/D information: Tx power |
| 1.3.6.1.4.1.4756.20.321.20.1.38 | Columnfom01DDRxPWRRemote | read-only | current | Remote device card fiber port D/D information: Rx power |
| 1.3.6.1.4.1.4756.20.321.20.1.39 | Columnfom01DDTempRemote | read-only | current | Remote device card fiber port D/D information: Temperature in degree C |
| 1.3.6.1.4.1.4756.20.321.20.1.40 | Columnfom01DDPWRMarginRemote | read-only | current | Remote device card fiber port D/D information: Power margin |
| 1.3.6.1.4.1.4756.20.321.20.1.41 | Columnfom01FxFEFRemote | read-only | current | Remote device card fiber detected Far End Fault: 0:Undetect 1:Detected |
| 1.3.6.1.4.1.4756.20.330 | Nodef1002ESCards | |||
| 1.3.6.1.4.1.4756.20.330.40 | Tablef1002ESTable | not-accessible | current | A list of local 1002ES card entries. |
| 1.3.6.1.4.1.4756.20.330.40.1 | Rowf1002ESEntry | not-accessible | current | An entry containing management information applicable to a particular f1002ES card. |
| 1.3.6.1.4.1.4756.20.330.40.1.1 | Columnf1002ESChassisIndex | read-only | current | A unique value for each chassis ID. For CH20, it is the chassis ID. For CH08, it is always 0. |
| 1.3.6.1.4.1.4756.20.330.40.1.2 | Columnf1002ESSlotIndex | read-only | current | A unique value for each local card. It is the slot location number. |
| 1.3.6.1.4.1.4756.20.330.40.1.3 | Columnf1002ESCardHWVer | read-only | current | device card hardware version x.xxx |
| 1.3.6.1.4.1.4756.20.330.40.1.4 | Columnf1002ESCardFWVer | read-only | current | device card firmware version x.xxx |
| 1.3.6.1.4.1.4756.20.330.40.1.5 | Columnf1002ESCardCPLDVer | read-only | current | device card CPLD version x.xxx |
| 1.3.6.1.4.1.4756.20.330.40.1.6 | Columnf1002ESCardFPGAVer | read-only | current | device card FPGA version x.xxx |
| 1.3.6.1.4.1.4756.20.330.40.1.7 | Columnf1002ESFiber1Link | read-only | current | device card fiber port 1 link status: 0:Down 1:Up |
| 1.3.6.1.4.1.4756.20.330.40.1.8 | Columnf1002ESFiber1LBTest | read-write | current | Force remote device card to do fiber port 1 LoopBack testing: 0:Off 1:Action |
| 1.3.6.1.4.1.4756.20.330.40.1.9 | Columnf1002ESFiber1IngressRate | read-write | current | device card fiber 1 Ingress Rate Limit: 0 = Unlimit input format: 64k(K),100m(M),100 If doesn't input the unit, the default was Mega. Limite Rate : 64K ~ 990M |
| 1.3.6.1.4.1.4756.20.330.40.1.10 | Columnf1002ESFiber1EgressRate | read-write | current | device card fiber 1 Egress Rate Limit: 0 = Unlimit input format: 64k(K),100m(M),100 If doesn't input the unit, the default was Mega. Limite Rate : 64K ~ 990M |
| 1.3.6.1.4.1.4756.20.330.40.1.11 | Columnf1002ESFiber2Link | read-only | current | device card fiber port 2 link status: 0:Down 1:Up |
| 1.3.6.1.4.1.4756.20.330.40.1.12 | Columnf1002ESFiber2LBTest | read-write | current | Force remote device card to do fiber port 2 LoopBack testing: 0:Off 1:Action |
| 1.3.6.1.4.1.4756.20.330.40.1.13 | Columnf1002ESFiber2IngressRate | read-write | current | device card fiber 2 Ingress Rate Limit: 0 = Unlimit input format: 64k(K),100m(M),100 If doesn't input the unit, the default was Mega. Limite Rate : 64K ~ 990M |
| 1.3.6.1.4.1.4756.20.330.40.1.14 | Columnf1002ESFiber2EgressRate | read-write | current | device card fiber 2 Egress Rate Limit: 0 = Unlimit input format: 64k(K),100m(M),100 If doesn't input the unit, the default was Mega. Limite Rate : 64K ~ 990M |
| 1.3.6.1.4.1.4756.20.330.40.1.15 | Columnf1002ESUtp3Link | read-only | current | device card UTP port 3 link status: 0:Down 1:Up |
| 1.3.6.1.4.1.4756.20.330.40.1.16 | Columnf1002ESUtp3Nego | read-write | current | device card UTP port 3 negotiation status: 0:Manual 1:Auto |
| 1.3.6.1.4.1.4756.20.330.40.1.17 | Columnf1002ESUtp3Speed | read-write | current | device card UTP port 3 speed setting: 0:10 Base-T 1:100 Base-TX 2:1000 Base-TX |
| 1.3.6.1.4.1.4756.20.330.40.1.18 | Columnf1002ESUtp3Duplex | read-write | current | device card UTP port 3 duplex setting: 0:Half duplex mode 1:Full duplex mode |
| 1.3.6.1.4.1.4756.20.330.40.1.19 | Columnf1002ESUtp3SpeedStatus | read-only | current | device card UTP port 3 speed status: 0:10 Base-T 1:100 Base-TX 2:1000 Base-TX |
| 1.3.6.1.4.1.4756.20.330.40.1.20 | Columnf1002ESUtp3DuplexStatus | read-only | current | device card UTP port 3 duplex status: 0:Half duplex mode 1:Full duplex mode |
| 1.3.6.1.4.1.4756.20.330.40.1.21 | Columnf1002ESUtp3IngressRate | read-write | current | device card utp 3 Ingress Rate Limit: 0 = Unlimit input format: 64k(K),100m(M),100 If doesn't input the unit, the default was Mega. Limite Rate : 64K ~ 990M |
| 1.3.6.1.4.1.4756.20.330.40.1.22 | Columnf1002ESUtp3EgressRate | read-write | current | device card utp 3 Egress Rate Limit: 0 = Unlimit input format: 64k(K),100m(M),100 If doesn't input the unit, the default was Mega. Limite Rate : 64K ~ 990M |
| 1.3.6.1.4.1.4756.20.330.40.1.23 | Columnf1002ESUtp3LBTest | read-write | current | Force remote device card to do utp port 3 LoopBack testing: 0:Off 1:Action |
| 1.3.6.1.4.1.4756.20.330.40.1.24 | Columnf1002ESUtp4Link | read-only | current | device card UTP port 4 link status: 0:Down 1:Up |
| 1.3.6.1.4.1.4756.20.330.40.1.25 | Columnf1002ESUtp4Nego | read-write | current | device card UTP port 4 negotiation status: 0:Manual 1:Auto |
| 1.3.6.1.4.1.4756.20.330.40.1.26 | Columnf1002ESUtp4Speed | read-write | current | device card UTP port 4 speed setting: 0:10 Base-T 1:100 Base-TX 2:1000 Base-TX |
| 1.3.6.1.4.1.4756.20.330.40.1.27 | Columnf1002ESUtp4Duplex | read-write | current | device card UTP port 4 duplex setting: 0:Half duplex mode 1:Full duplex mode |
| 1.3.6.1.4.1.4756.20.330.40.1.28 | Columnf1002ESUtp4SpeedStatus | read-only | current | device card UTP port 4 speed status: 0:10 Base-T 1:100 Base-TX 2:1000 Base-TX |
| 1.3.6.1.4.1.4756.20.330.40.1.29 | Columnf1002ESUtp4DuplexStatus | read-only | current | device card UTP port 4 duplex status: 0:Half duplex mode 1:Full duplex mode |
| 1.3.6.1.4.1.4756.20.330.40.1.30 | Columnf1002ESUtp4IngressRate | read-write | current | device card utp 4 Ingress Rate Limit: 0 = Unlimit input format: 64k(K),100m(M),100 If doesn't input the unit, the default was Mega. Limite Rate : 64K ~ 990M |
| 1.3.6.1.4.1.4756.20.330.40.1.31 | Columnf1002ESUtp4EgressRate | read-write | current | device card utp 4 Egress Rate Limit: 0 = Unlimit input format: 64k(K),100m(M),100 If doesn't input the unit, the default was Mega. Limite Rate : 64K ~ 990M |
| 1.3.6.1.4.1.4756.20.330.40.1.32 | Columnf1002ESUtp4LBTest | read-write | current | Force remote device card to do utp port 4 LoopBack testing: 0:Off 1:Action |
| 1.3.6.1.4.1.4756.20.330.40.1.33 | Columnf1002ESDeviceActive | read-write | current | device card active mode: (It is read-only in local device.) 0:Disable 1:Enable |
| 1.3.6.1.4.1.4756.20.330.40.1.34 | Columnf1002ESDeviceReset | read-write | current | Force local device card to reset mode: 0:Off 1:Action |
| 1.3.6.1.4.1.4756.20.330.40.1.35 | Columnf1002ESFiber1Active | read-write | current | device fiber port 1 active mode: 0:Disable 1:Enable |
| 1.3.6.1.4.1.4756.20.330.40.1.36 | Columnf1002ESFiber2Active | read-write | current | device fiber port 2 active mode: 0:Disable 1:Enable |
| 1.3.6.1.4.1.4756.20.330.40.1.37 | Columnf1002ESUtp3Active | read-write | current | device UTP port 3 active mode: 0:Disable 1:Enable |
| 1.3.6.1.4.1.4756.20.330.40.1.38 | Columnf1002ESUtp4Active | read-write | current | device UTP port 4 active mode: 0:Disable 1:Enable |
| 1.3.6.1.4.1.4756.20.330.40.1.39 | Columnf1002ESFiber1Als | read-write | current | device card port 1 Auto Laser Shutdown mode: 0:Disable 1:Enable |
| 1.3.6.1.4.1.4756.20.330.40.1.40 | Columnf1002ESFiber2Als | read-write | current | device card port 2 Auto Laser Shutdown mode: 0:Disable 1:Enable |
| 1.3.6.1.4.1.4756.20.330.40.1.41 | Columnf1002ESFiber1LLFDepLogi | read-write | current | device card port 1 Link Loss Forwarding depends boolean logic: 0:and 1:or |
| 1.3.6.1.4.1.4756.20.330.40.1.42 | Columnf1002ESFiber1LLFDepPort2 | read-write | current | device card port 1 Link Loss Forwarding depends on port 2 Fiber Rx link: 0:don't care 1:selected |
| 1.3.6.1.4.1.4756.20.330.40.1.43 | Columnf1002ESFiber1LLFDepPort3 | read-write | current | device card port 1 Link Loss Forwarding depends on port 3 Ethernet Rx link: 0:don't care 1:selected |
| 1.3.6.1.4.1.4756.20.330.40.1.44 | Columnf1002ESFiber1LLFDepPort4 | read-write | current | device card port 1 Link Loss Forwarding depends on port 4 Ethernet Rx link: 0:don't care 1:selected |
| 1.3.6.1.4.1.4756.20.330.40.1.45 | Columnf1002ESFiber2LLFDepLogi | read-write | current | device card port 2 Link Loss Forwarding depends boolean logic: 0:and 1:or |
| 1.3.6.1.4.1.4756.20.330.40.1.46 | Columnf1002ESFiber2LLFDepPort1 | read-write | current | device card port 2 Link Loss Forwarding depends on port 1 Fiber Rx link: 0:don't care 1:selected |
| 1.3.6.1.4.1.4756.20.330.40.1.47 | Columnf1002ESFiber2LLFDepPort3 | read-write | current | device card port 2 Link Loss Forwarding depends on port 3 Ethernet Rx link: 0:don't care 1:selected |
| 1.3.6.1.4.1.4756.20.330.40.1.48 | Columnf1002ESFiber2LLFDepPort4 | read-write | current | device card port 2 Link Loss Forwarding depends on port 4 Ethernet Rx link: 0:don't care 1:selected |
| 1.3.6.1.4.1.4756.20.330.40.1.49 | Columnf1002ESUtp3LLFDepLogi | read-write | current | device card port 3 Link Loss Forwarding depends boolean logic: 0:and 1:or |
| 1.3.6.1.4.1.4756.20.330.40.1.50 | Columnf1002ESUtp3LLFDepPort1 | read-write | current | device card port 3 Link Loss Forwarding depends on port 1 Rx link: 0:don't care 1:selected |
| 1.3.6.1.4.1.4756.20.330.40.1.51 | Columnf1002ESUtp3LLFDepPort2 | read-write | current | device card port 3 Link Loss Forwarding depends on port 2 Rx link: 0:don't care 1:selected |
| 1.3.6.1.4.1.4756.20.330.40.1.52 | Columnf1002ESUtp3LLFDepPort4 | read-write | current | device card port 3 Link Loss Forwarding depends on port 4 Rx link: 0:don't care 1:selected |
| 1.3.6.1.4.1.4756.20.330.40.1.53 | Columnf1002ESUtp4LLFDepLogi | read-write | current | device card port 4 Link Loss Forwarding depends boolean logic: 0:and 1:or |
| 1.3.6.1.4.1.4756.20.330.40.1.54 | Columnf1002ESUtp4LLFDepPort1 | read-write | current | device card port 4 Link Loss Forwarding depends on port 1 Rx link: 0:don't care 1:selected |
| 1.3.6.1.4.1.4756.20.330.40.1.55 | Columnf1002ESUtp4LLFDepPort2 | read-write | current | device card port 4 Link Loss Forwarding depends on port 2 Rx link: 0:don't care 1:selected |
| 1.3.6.1.4.1.4756.20.330.40.1.56 | Columnf1002ESUtp4LLFDepPort3 | read-write | current | device card port 4 Link Loss Forwarding depends on port 3 Rx link: 0:don't care 1:selected |
| 1.3.6.1.4.1.4756.20.330.40.1.57 | Columnf1002ESFiber1DD | read-only | current | device card fiber port 1 Digital Diagnostic function: 0:No 1:Yes |
| 1.3.6.1.4.1.4756.20.330.40.1.58 | Columnf1002ESFiber1DDVendor | read-only | current | device card fiber port 1 D/D information: Vendor name |
| 1.3.6.1.4.1.4756.20.330.40.1.59 | Columnf1002ESFiber1DDPartNo | read-only | current | device card fiber port 1 D/D information: Vendor part number |
| 1.3.6.1.4.1.4756.20.330.40.1.60 | Columnf1002ESFiber1DDFiberType | read-only | current | device card fiber port 1 D/D information: Fiber Type |
| 1.3.6.1.4.1.4756.20.330.40.1.61 | Columnf1002ESFiber1DDWaveLen | read-only | current | device card fiber port 1 D/D information: Wave length |
| 1.3.6.1.4.1.4756.20.330.40.1.62 | Columnf1002ESFiber1DDWaveLen2 | read-only | current | device card fiber port 1 D/D information: Wave length 2 |
| 1.3.6.1.4.1.4756.20.330.40.1.63 | Columnf1002ESFiber1DDLinkLen | read-only | current | device card fiber port 1 D/D information: Link length |
| 1.3.6.1.4.1.4756.20.330.40.1.64 | Columnf1002ESFiber1DDLenUnit | read-only | current | device card fiber port 1 D/D information: Length Unit |
| 1.3.6.1.4.1.4756.20.330.40.1.65 | Columnf1002ESFiber1DDStatus | read-only | current | device card fiber port 1 D/D information: Status Support |
| 1.3.6.1.4.1.4756.20.330.40.1.66 | Columnf1002ESFiber1DDRxSens | read-only | current | device card fiber port 1 D/D information: Rx Sensitivity |
| 1.3.6.1.4.1.4756.20.330.40.1.67 | Columnf1002ESFiber1DDTxPWR | read-only | current | device card fiber port 1 D/D information: Tx power |
| 1.3.6.1.4.1.4756.20.330.40.1.68 | Columnf1002ESFiber1DDRxPWR | read-only | current | device card fiber port 1 D/D information: Rx power |
| 1.3.6.1.4.1.4756.20.330.40.1.69 | Columnf1002ESFiber1DDTemp | read-only | current | device card fiber port 1 D/D information: Temperature in degree C |
| 1.3.6.1.4.1.4756.20.330.40.1.70 | Columnf1002ESFiber1DDPWRMargin | read-only | current | device card fiber port 1 D/D information: Power margin |
| 1.3.6.1.4.1.4756.20.330.40.1.71 | Columnf1002ESFiber1DDPWRLoss | read-only | current | device card fiber port 1 D/D information: Power loss |
| 1.3.6.1.4.1.4756.20.330.40.1.72 | Columnf1002ESFiber2DD | read-only | current | device card fiber port 2 Digital Diagnostic function: 0:No 1:Yes |
| 1.3.6.1.4.1.4756.20.330.40.1.73 | Columnf1002ESFiber2DDVendor | read-only | current | device card fiber port 2 D/D information: Vendor name |
| 1.3.6.1.4.1.4756.20.330.40.1.74 | Columnf1002ESFiber2DDPartNo | read-only | current | device card fiber port 2 D/D information: Vendor part number |
| 1.3.6.1.4.1.4756.20.330.40.1.75 | Columnf1002ESFiber2DDFiberType | read-only | current | device card fiber port 2 D/D information: Fiber Type |
| 1.3.6.1.4.1.4756.20.330.40.1.76 | Columnf1002ESFiber2DDWaveLen | read-only | current | device card fiber port 2 D/D information: Wave length |
| 1.3.6.1.4.1.4756.20.330.40.1.77 | Columnf1002ESFiber2DDWaveLen2 | read-only | current | device card fiber port 2 D/D information: Wave length 2 |
| 1.3.6.1.4.1.4756.20.330.40.1.78 | Columnf1002ESFiber2DDLinkLen | read-only | current | device card fiber port 2 D/D information: Link length |
| 1.3.6.1.4.1.4756.20.330.40.1.79 | Columnf1002ESFiber2DDLenUnit | read-only | current | device card fiber port 2 D/D information: Length Unit |
| 1.3.6.1.4.1.4756.20.330.40.1.80 | Columnf1002ESFiber2DDStatus | read-only | current | device card fiber port 2 D/D information: Status Support |
| 1.3.6.1.4.1.4756.20.330.40.1.81 | Columnf1002ESFiber2DDRxSens | read-only | current | device card fiber port 2 D/D information: Rx Sensitivity |
| 1.3.6.1.4.1.4756.20.330.40.1.82 | Columnf1002ESFiber2DDTxPWR | read-only | current | device card fiber port 2 D/D information: Tx power |
| 1.3.6.1.4.1.4756.20.330.40.1.83 | Columnf1002ESFiber2DDRxPWR | read-only | current | device card fiber port 2 D/D information: Rx power |
| 1.3.6.1.4.1.4756.20.330.40.1.84 | Columnf1002ESFiber2DDTemp | read-only | current | device card fiber port 2 D/D information: Temperature in degree C |
| 1.3.6.1.4.1.4756.20.330.40.1.85 | Columnf1002ESFiber2DDPWRMargin | read-only | current | device card fiber port 2 D/D information: Power margin |
| 1.3.6.1.4.1.4756.20.330.40.1.86 | Columnf1002ESFiber2DDPWRLoss | read-only | current | device card fiber port 2 D/D information: Power loss |
| 1.3.6.1.4.1.4756.20.330.40.1.87 | Columnf1002ESClrRMONCnts | read-write | current | Clear local device card RMON IN/OUT counters: 0:No action 1:Action |
| 1.3.6.1.4.1.4756.20.330.40.1.88 | Columnf1002ESFiber1RMONIn | read-only | current | device card port 1 RMON IN counter. |
| 1.3.6.1.4.1.4756.20.330.40.1.89 | Columnf1002ESFiber1RMONOut | read-only | current | device card port 1 RMON OUT counter. |
| 1.3.6.1.4.1.4756.20.330.40.1.90 | Columnf1002ESFiber2RMONIn | read-only | current | device card port 2 RMON IN counter. |
| 1.3.6.1.4.1.4756.20.330.40.1.91 | Columnf1002ESFiber2RMONOut | read-only | current | device card port 2 RMON OUT counter. |
| 1.3.6.1.4.1.4756.20.330.40.1.92 | Columnf1002ESUtp3RMONIn | read-only | current | device card port 3 RMON IN counter. |
| 1.3.6.1.4.1.4756.20.330.40.1.93 | Columnf1002ESUtp3RMONOut | read-only | current | device card port 3 RMON OUT counter. |
| 1.3.6.1.4.1.4756.20.330.40.1.94 | Columnf1002ESUtp4RMONIn | read-only | current | device card port 4 RMON IN counter. |
| 1.3.6.1.4.1.4756.20.330.40.1.95 | Columnf1002ESUtp4RMONOut | read-only | current | device card port 4 RMON OUT counter. |
| 1.3.6.1.4.1.4756.20.330.40.1.96 | Columnf1002ESFiber1Speed | read-write | current | device Fiber 1 speed : 0:1000 1:100 |
| 1.3.6.1.4.1.4756.20.330.40.1.97 | Columnf1002ESFiber2Speed | read-write | current | device Fiber 2 speed : 0:1000 1:100 |
| 1.3.6.1.4.1.4756.20.330.40.1.98 | Columnf1002ESFiber1VLAN | read-write | current | device Fiber 1 VLAN group : 0:Group A 1:Group B |
| 1.3.6.1.4.1.4756.20.330.40.1.99 | Columnf1002ESFiber2VLAN | read-write | current | device Fiber 2 VLAN group : 0:Group A 1:Group B |
| 1.3.6.1.4.1.4756.20.330.40.1.100 | Columnf1002ESUtp3VLAN | read-write | current | device UTP 3 VLAN group : 0:Group A 1:Group B |
| 1.3.6.1.4.1.4756.20.330.40.1.101 | Columnf1002ESUtp4VLAN | read-write | current | device UTP 4 VLAN group : 0:Group A 1:Group B |
| 1.3.6.1.4.1.4756.20.330.40.1.102 | Columnf1002ESPortVLAN | read-write | current | device Port VLAN mode : 0:Disalbe 1:Enable |
| 1.3.6.1.4.1.4756.20.330.40.1.103 | Columnf1002ES8021QVLAN | read-write | current | device 802.1Q VLAN : 0:Disalbe 1:Enable |
| 1.3.6.1.4.1.4756.20.330.40.1.104 | Columnf1002ESFlowCrl | read-write | current | device Flow Control : 0:Disalbe 1:Enable |
| 1.3.6.1.4.1.4756.20.330.40.1.105 | Columnf1002ESTagType | read-write | current | device Tag Type (HEX) : |
| 1.3.6.1.4.1.4756.20.330.40.1.106 | Columnf1002ESPort1VID | read-write | current | device Port 1 VID : |
| 1.3.6.1.4.1.4756.20.330.40.1.107 | Columnf1002ESPort2VID | read-write | current | device Port 2 VID : |
| 1.3.6.1.4.1.4756.20.330.40.1.108 | Columnf1002ESPort3VID | read-write | current | device Port 3 VID : |
| 1.3.6.1.4.1.4756.20.330.40.1.109 | Columnf1002ESPort4VID | read-write | current | device Port 4 VID : |
| 1.3.6.1.4.1.4756.20.330.40.1.110 | Columnf1002ESPort1QinQ | read-write | current | device Port 1 Q in Q Support : 1:Disable 2:Enable |
| 1.3.6.1.4.1.4756.20.330.40.1.111 | Columnf1002ESPort2QinQ | read-write | current | device Port 2 Q in Q Support : 1:Disable 2:Enable |
| 1.3.6.1.4.1.4756.20.330.40.1.112 | Columnf1002ESPort3QinQ | read-write | current | device Port 3 Q in Q Support : 1:Disable 2:Enable |
| 1.3.6.1.4.1.4756.20.330.40.1.113 | Columnf1002ESPort4QinQ | read-write | current | device Port 4 Q in Q Support : 1:Disable 2:Enable |
| 1.3.6.1.4.1.4756.20.330.40.1.114 | Columnf1002ESVID1 | read-write | current | device VID 1: |
| 1.3.6.1.4.1.4756.20.330.40.1.115 | Columnf1002ESVID2 | read-write | current | device VID 2: |
| 1.3.6.1.4.1.4756.20.330.40.1.116 | Columnf1002ESVID3 | read-write | current | device VID 3: |
| 1.3.6.1.4.1.4756.20.330.40.1.117 | Columnf1002ESVID4 | read-write | current | device VID 4: |
| 1.3.6.1.4.1.4756.20.330.40.1.118 | Columnf1002ESVID5 | read-write | current | device VID 5: |
| 1.3.6.1.4.1.4756.20.330.40.1.119 | Columnf1002ESVID6 | read-write | current | device VID 6: |
| 1.3.6.1.4.1.4756.20.330.40.1.120 | Columnf1002ESVID7 | read-write | current | device VID 7: |
| 1.3.6.1.4.1.4756.20.330.40.1.121 | Columnf1002ESVID8 | read-write | current | device VID 8: |
| 1.3.6.1.4.1.4756.20.330.40.1.122 | Columnf1002ESVID9 | read-write | current | device VID 9: |
| 1.3.6.1.4.1.4756.20.330.40.1.123 | Columnf1002ESVID10 | read-write | current | device VID 10: |
| 1.3.6.1.4.1.4756.20.330.40.1.124 | Columnf1002ESVID11 | read-write | current | device VID 11: |
| 1.3.6.1.4.1.4756.20.330.40.1.125 | Columnf1002ESVID12 | read-write | current | device VID 12: |
| 1.3.6.1.4.1.4756.20.330.40.1.126 | Columnf1002ESVID13 | read-write | current | device VID 13: |
| 1.3.6.1.4.1.4756.20.330.40.1.127 | Columnf1002ESVID14 | read-write | current | device VID 14: |
| 1.3.6.1.4.1.4756.20.330.40.1.128 | Columnf1002ESVID15 | read-write | current | device VID 15: |
| 1.3.6.1.4.1.4756.20.330.40.1.129 | Columnf1002ESVID16 | read-write | current | device VID 16: |
| 1.3.6.1.4.1.4756.20.330.40.1.130 | Columnf1002ESPort1Member1 | read-write | current | device card port 1 member: 0:Unmodify 1:Untagged 2:Tagged 3:Nonmember |
| 1.3.6.1.4.1.4756.20.330.40.1.131 | Columnf1002ESPort1Member2 | read-write | current | device card port 1 member 2: 0:Unmodify 1:Untagged 2:Tagged 3:Nonmember |
| 1.3.6.1.4.1.4756.20.330.40.1.132 | Columnf1002ESPort1Member3 | read-write | current | device card port 1 member 3: 0:Unmodify 1:Untagged 2:Tagged 3:Nonmember |
| 1.3.6.1.4.1.4756.20.330.40.1.133 | Columnf1002ESPort1Member4 | read-write | current | device card port 1 member 4: 0:Unmodify 1:Untagged 2:Tagged 3:Nonmember |
| 1.3.6.1.4.1.4756.20.330.40.1.134 | Columnf1002ESPort1Member5 | read-write | current | device card port 1 member 5: 0:Unmodify 1:Untagged 2:Tagged 3:Nonmember |
| 1.3.6.1.4.1.4756.20.330.40.1.135 | Columnf1002ESPort1Member6 | read-write | current | device card port 1 member 6: 0:Unmodify 1:Untagged 2:Tagged 3:Nonmember |
| 1.3.6.1.4.1.4756.20.330.40.1.136 | Columnf1002ESPort1Member7 | read-write | current | device card port 1 member 7: 0:Unmodify 1:Untagged 2:Tagged 3:Nonmember |
| 1.3.6.1.4.1.4756.20.330.40.1.137 | Columnf1002ESPort1Member8 | read-write | current | device card port 1 member 8: 0:Unmodify 1:Untagged 2:Tagged 3:Nonmember |
| 1.3.6.1.4.1.4756.20.330.40.1.138 | Columnf1002ESPort1Member9 | read-write | current | device card port 1 member 9: 0:Unmodify 1:Untagged 2:Tagged 3:Nonmember |
| 1.3.6.1.4.1.4756.20.330.40.1.139 | Columnf1002ESPort1Member10 | read-write | current | device card port 1 member 10: 0:Unmodify 1:Untagged 2:Tagged 3:Nonmember |
| 1.3.6.1.4.1.4756.20.330.40.1.140 | Columnf1002ESPort1Member11 | read-write | current | device card port 1 member 11: 0:Unmodify 1:Untagged 2:Tagged 3:Nonmember |
| 1.3.6.1.4.1.4756.20.330.40.1.141 | Columnf1002ESPort1Member12 | read-write | current | device card port 1 member 12: 0:Unmodify 1:Untagged 2:Tagged 3:Nonmember |
| 1.3.6.1.4.1.4756.20.330.40.1.142 | Columnf1002ESPort1Member13 | read-write | current | device card port 1 member 13: 0:Unmodify 1:Untagged 2:Tagged 3:Nonmember |
| 1.3.6.1.4.1.4756.20.330.40.1.143 | Columnf1002ESPort1Member14 | read-write | current | device card port 1 member 14: 0:Unmodify 1:Untagged 2:Tagged 3:Nonmember |
| 1.3.6.1.4.1.4756.20.330.40.1.144 | Columnf1002ESPort1Member15 | read-write | current | device card port 1 member 15: 0:Unmodify 1:Untagged 2:Tagged 3:Nonmember |
| 1.3.6.1.4.1.4756.20.330.40.1.145 | Columnf1002ESPort1Member16 | read-write | current | device card port 1 member 16: 0:Unmodify 1:Untagged 2:Tagged 3:Nonmember |
| 1.3.6.1.4.1.4756.20.330.40.1.146 | Columnf1002ESPort2Member1 | read-write | current | device card port 2 member: 0:Unmodify 1:Untagged 2:Tagged 3:Nonmember |
| 1.3.6.1.4.1.4756.20.330.40.1.147 | Columnf1002ESPort2Member2 | read-write | current | device card port 2 member 2: 0:Unmodify 1:Untagged 2:Tagged 3:Nonmember |
| 1.3.6.1.4.1.4756.20.330.40.1.148 | Columnf1002ESPort2Member3 | read-write | current | device card port 2 member 3: 0:Unmodify 1:Untagged 2:Tagged 3:Nonmember |
| 1.3.6.1.4.1.4756.20.330.40.1.149 | Columnf1002ESPort2Member4 | read-write | current | device card port 2 member 4: 0:Unmodify 1:Untagged 2:Tagged 3:Nonmember |
| 1.3.6.1.4.1.4756.20.330.40.1.150 | Columnf1002ESPort2Member5 | read-write | current | device card port 2 member 5: 0:Unmodify 1:Untagged 2:Tagged 3:Nonmember |
| 1.3.6.1.4.1.4756.20.330.40.1.151 | Columnf1002ESPort2Member6 | read-write | current | device card port 2 member 6: 0:Unmodify 1:Untagged 2:Tagged 3:Nonmember |
| 1.3.6.1.4.1.4756.20.330.40.1.152 | Columnf1002ESPort2Member7 | read-write | current | device card port 2 member 7: 0:Unmodify 1:Untagged 2:Tagged 3:Nonmember |
| 1.3.6.1.4.1.4756.20.330.40.1.153 | Columnf1002ESPort2Member8 | read-write | current | device card port 2 member 8: 0:Unmodify 1:Untagged 2:Tagged 3:Nonmember |
| 1.3.6.1.4.1.4756.20.330.40.1.154 | Columnf1002ESPort2Member9 | read-write | current | device card port 2 member 9: 0:Unmodify 1:Untagged 2:Tagged 3:Nonmember |
| 1.3.6.1.4.1.4756.20.330.40.1.155 | Columnf1002ESPort2Member10 | read-write | current | device card port 2 member 10: 0:Unmodify 1:Untagged 2:Tagged 3:Nonmember |
| 1.3.6.1.4.1.4756.20.330.40.1.156 | Columnf1002ESPort2Member11 | read-write | current | device card port 2 member 11: 0:Unmodify 1:Untagged 2:Tagged 3:Nonmember |
| 1.3.6.1.4.1.4756.20.330.40.1.157 | Columnf1002ESPort2Member12 | read-write | current | device card port 2 member 12: 0:Unmodify 1:Untagged 2:Tagged 3:Nonmember |
| 1.3.6.1.4.1.4756.20.330.40.1.158 | Columnf1002ESPort2Member13 | read-write | current | device card port 2 member 13: 0:Unmodify 1:Untagged 2:Tagged 3:Nonmember |
| 1.3.6.1.4.1.4756.20.330.40.1.159 | Columnf1002ESPort2Member14 | read-write | current | device card port 2 member 14: 0:Unmodify 1:Untagged 2:Tagged 3:Nonmember |
| 1.3.6.1.4.1.4756.20.330.40.1.160 | Columnf1002ESPort2Member15 | read-write | current | device card port 2 member 15: 0:Unmodify 1:Untagged 2:Tagged 3:Nonmember |
| 1.3.6.1.4.1.4756.20.330.40.1.161 | Columnf1002ESPort2Member16 | read-write | current | device card port 2 member 16: 0:Unmodify 1:Untagged 2:Tagged 3:Nonmember |
| 1.3.6.1.4.1.4756.20.330.40.1.162 | Columnf1002ESPort3Member1 | read-write | current | device card port 3 member: 0:Unmodify 1:Untagged 2:Tagged 3:Nonmember |
| 1.3.6.1.4.1.4756.20.330.40.1.163 | Columnf1002ESPort3Member2 | read-write | current | device card port 3 member 2: 0:Unmodify 1:Untagged 2:Tagged 3:Nonmember |
| 1.3.6.1.4.1.4756.20.330.40.1.164 | Columnf1002ESPort3Member3 | read-write | current | device card port 3 member 3: 0:Unmodify 1:Untagged 2:Tagged 3:Nonmember |
| 1.3.6.1.4.1.4756.20.330.40.1.165 | Columnf1002ESPort3Member4 | read-write | current | device card port 3 member 4: 0:Unmodify 1:Untagged 2:Tagged 3:Nonmember |
| 1.3.6.1.4.1.4756.20.330.40.1.166 | Columnf1002ESPort3Member5 | read-write | current | device card port 3 member 5: 0:Unmodify 1:Untagged 2:Tagged 3:Nonmember |
| 1.3.6.1.4.1.4756.20.330.40.1.167 | Columnf1002ESPort3Member6 | read-write | current | device card port 3 member 6: 0:Unmodify 1:Untagged 2:Tagged 3:Nonmember |
| 1.3.6.1.4.1.4756.20.330.40.1.168 | Columnf1002ESPort3Member7 | read-write | current | device card port 3 member 7: 0:Unmodify 1:Untagged 2:Tagged 3:Nonmember |
| 1.3.6.1.4.1.4756.20.330.40.1.169 | Columnf1002ESPort3Member8 | read-write | current | device card port 3 member 8: 0:Unmodify 1:Untagged 2:Tagged 3:Nonmember |
| 1.3.6.1.4.1.4756.20.330.40.1.170 | Columnf1002ESPort3Member9 | read-write | current | device card port 3 member 9: 0:Unmodify 1:Untagged 2:Tagged 3:Nonmember |
| 1.3.6.1.4.1.4756.20.330.40.1.171 | Columnf1002ESPort3Member10 | read-write | current | device card port 3 member 10: 0:Unmodify 1:Untagged 2:Tagged 3:Nonmember |
| 1.3.6.1.4.1.4756.20.330.40.1.172 | Columnf1002ESPort3Member11 | read-write | current | device card port 3 member 11: 0:Unmodify 1:Untagged 2:Tagged 3:Nonmember |
| 1.3.6.1.4.1.4756.20.330.40.1.173 | Columnf1002ESPort3Member12 | read-write | current | device card port 3 member 12: 0:Unmodify 1:Untagged 2:Tagged 3:Nonmember |
| 1.3.6.1.4.1.4756.20.330.40.1.174 | Columnf1002ESPort3Member13 | read-write | current | device card port 3 member 13: 0:Unmodify 1:Untagged 2:Tagged 3:Nonmember |
| 1.3.6.1.4.1.4756.20.330.40.1.175 | Columnf1002ESPort3Member14 | read-write | current | device card port 3 member 14: 0:Unmodify 1:Untagged 2:Tagged 3:Nonmember |
| 1.3.6.1.4.1.4756.20.330.40.1.176 | Columnf1002ESPort3Member15 | read-write | current | device card port 3 member 15: 0:Unmodify 1:Untagged 2:Tagged 3:Nonmember |
| 1.3.6.1.4.1.4756.20.330.40.1.177 | Columnf1002ESPort3Member16 | read-write | current | device card port 3 member 16: 0:Unmodify 1:Untagged 2:Tagged 3:Nonmember |
| 1.3.6.1.4.1.4756.20.330.40.1.178 | Columnf1002ESPort4Member1 | read-write | current | device card port 4 member: 0:Unmodify 1:Untagged 2:Tagged 3:Nonmember |
| 1.3.6.1.4.1.4756.20.330.40.1.179 | Columnf1002ESPort4Member2 | read-write | current | device card port 4 member 2: 0:Unmodify 1:Untagged 2:Tagged 3:Nonmember |
| 1.3.6.1.4.1.4756.20.330.40.1.180 | Columnf1002ESPort4Member3 | read-write | current | device card port 4 member 3: 0:Unmodify 1:Untagged 2:Tagged 3:Nonmember |
| 1.3.6.1.4.1.4756.20.330.40.1.181 | Columnf1002ESPort4Member4 | read-write | current | device card port 4 member 4: 0:Unmodify 1:Untagged 2:Tagged 3:Nonmember |
| 1.3.6.1.4.1.4756.20.330.40.1.182 | Columnf1002ESPort4Member5 | read-write | current | device card port 4 member 5: 0:Unmodify 1:Untagged 2:Tagged 3:Nonmember |
| 1.3.6.1.4.1.4756.20.330.40.1.183 | Columnf1002ESPort4Member6 | read-write | current | device card port 4 member 6: 0:Unmodify 1:Untagged 2:Tagged 3:Nonmember |
| 1.3.6.1.4.1.4756.20.330.40.1.184 | Columnf1002ESPort4Member7 | read-write | current | device card port 4 member 7: 0:Unmodify 1:Untagged 2:Tagged 3:Nonmember |
| 1.3.6.1.4.1.4756.20.330.40.1.185 | Columnf1002ESPort4Member8 | read-write | current | device card port 4 member 8: 0:Unmodify 1:Untagged 2:Tagged 3:Nonmember |
| 1.3.6.1.4.1.4756.20.330.40.1.186 | Columnf1002ESPort4Member9 | read-write | current | device card port 4 member 9: 0:Unmodify 1:Untagged 2:Tagged 3:Nonmember |
| 1.3.6.1.4.1.4756.20.330.40.1.187 | Columnf1002ESPort4Member10 | read-write | current | device card port 4 member 10: 0:Unmodify 1:Untagged 2:Tagged 3:Nonmember |
| 1.3.6.1.4.1.4756.20.330.40.1.188 | Columnf1002ESPort4Member11 | read-write | current | device card port 4 member 11: 0:Unmodify 1:Untagged 2:Tagged 3:Nonmember |
| 1.3.6.1.4.1.4756.20.330.40.1.189 | Columnf1002ESPort4Member12 | read-write | current | device card port 4 member 12: 0:Unmodify 1:Untagged 2:Tagged 3:Nonmember |
| 1.3.6.1.4.1.4756.20.330.40.1.190 | Columnf1002ESPort4Member13 | read-write | current | device card port 4 member 13: 0:Unmodify 1:Untagged 2:Tagged 3:Nonmember |
| 1.3.6.1.4.1.4756.20.330.40.1.191 | Columnf1002ESPort4Member14 | read-write | current | device card port 4 member 14: 0:Unmodify 1:Untagged 2:Tagged 3:Nonmember |
| 1.3.6.1.4.1.4756.20.330.40.1.192 | Columnf1002ESPort4Member15 | read-write | current | device card port 4 member 15: 0:Unmodify 1:Untagged 2:Tagged 3:Nonmember |
| 1.3.6.1.4.1.4756.20.330.40.1.193 | Columnf1002ESPort4Member16 | read-write | current | device card port 4 member 16: 0:Unmodify 1:Untagged 2:Tagged 3:Nonmember |
| 1.3.6.1.4.1.4756.20.330.40.1.194 | Columnf1002ESSetToDefault | read-write | current | device card set to default: 0:Off 1:Action |
| 1.3.6.1.4.1.4756.20.340 | Nodefet100LocalCards | |||
| 1.3.6.1.4.1.4756.20.340.20 | Tablefet100LocalTable | not-accessible | current | A list of local FRM220-ET100 card entries. The number of entries is fET100-No-L. |
| 1.3.6.1.4.1.4756.20.340.20.1 | Rowfet100LocalEntry | not-accessible | current | An entry containing management information applicable to a particular local FRM220-ET100 card. |
| 1.3.6.1.4.1.4756.20.340.20.1.1 | Columnfet100ChassisIndexLocal | read-only | current | A unique value for each local card. It is the chassis location number. |
| 1.3.6.1.4.1.4756.20.340.20.1.2 | Columnfet100SlotIndexLocal | read-only | current | A unique value for each local card. It is the slot location number. |
| 1.3.6.1.4.1.4756.20.340.20.1.3 | Columnfet100CardHWVerLocal | read-only | current | Local FRM220-ET100 card hardware version x.xxx |
| 1.3.6.1.4.1.4756.20.340.20.1.4 | Columnfet100CardFWVerLocal | read-only | current | Local FRM220-ET100 card firmware version x.xxx |
| 1.3.6.1.4.1.4756.20.340.20.1.5 | Columnfet100CardCPLDVerLocal | read-only | current | Local FRM220-ET100 card CPLD version x.xxx |
| 1.3.6.1.4.1.4756.20.340.20.1.6 | Columnfet100CardFPGAVerLocal | read-only | current | Local FRM220-ET100 card FPGA version x.xxx |
| 1.3.6.1.4.1.4756.20.340.20.1.7 | Columnfet100PortActiveLocal | read-write | current | Local FRM220-ET100 card active: 0:Disable 1:Enable |
| 1.3.6.1.4.1.4756.20.340.20.1.8 | Columnfet100PortResetLocal | read-write | current | Force local FRM220-ET100 card to reset mode: 0:Off 1:Action |
| 1.3.6.1.4.1.4756.20.340.20.1.9 | Columnfet100SetDefaultLocal | read-write | current | Force local FRM220-ET100 card to default status: 0:Off 1:Action |
| 1.3.6.1.4.1.4756.20.340.20.1.10 | Columnfet100PowerLedLocal | read-only | current | Local FRM220-ET100 card Power led status: 0:Off 1:On 2:Flash |
| 1.3.6.1.4.1.4756.20.340.20.1.11 | Columnfet100SYSLedLocal | read-only | current | Local FRM220-ET100 card system led status: 0:Off 1:On |
| 1.3.6.1.4.1.4756.20.340.20.1.12 | Columnfet100AlarmLedLocal | read-only | current | Local FRM220-ET100 card alarm led status: 0:Off 1:On |
| 1.3.6.1.4.1.4756.20.340.20.1.13 | Columnfet100TestLedLocal | read-only | current | Local FRM220-ET100 card test led status: 0:Off 1:On |
| 1.3.6.1.4.1.4756.20.340.20.1.14 | Columnfet100FxLinkLocal | read-only | current | Local FRM220-ET100 card fiber link: 0:Down 1:Up |
| 1.3.6.1.4.1.4756.20.340.20.1.15 | Columnfet100FxSignalAppearLocal | read-only | current | Local FRM220-ET100 card fiber signal appear: 0:Off 1:Have |
| 1.3.6.1.4.1.4756.20.340.20.1.16 | Columnfet100FxSignalLossLocal | read-only | current | Local FRM220-ET100 card fiber singal loss: 0:Off 1:Have |
| 1.3.6.1.4.1.4756.20.340.20.1.17 | Columnfet100FxSignalLocal | read-only | current | Local FRM220-ET100 card signal : 0:No 1:Yes |
| 1.3.6.1.4.1.4756.20.340.20.1.18 | Columnfet100FEFLocal | read-only | current | Local FRM220-ET100 card fiber detected Far End Fault: 0:Off 1:Detected |
| 1.3.6.1.4.1.4756.20.340.20.1.19 | Columnfet100FxTypeLocal | read-only | current | Local FRM220-ET100 card fiber type: 0:1*9 1:SFP |
| 1.3.6.1.4.1.4756.20.340.20.1.20 | Columnfet100AlsLocal | read-write | current | Local FRM220-ET100 card Auto Laser Shutdown: 0:disable 1:enable |
| 1.3.6.1.4.1.4756.20.340.20.1.21 | Columnfet100E1T1selLocal | read-write | current | Local FRM220-ET100 card ET100 Select: 0:e1 1:t1 |
| 1.3.6.1.4.1.4756.20.340.20.1.22 | Columnfet100FullFractionalLocal | read-write | current | Local FRM220-ET100 card ET100 Full/Fractional: 0:full-e1t1 1:fraction-e1t1 |
| 1.3.6.1.4.1.4756.20.340.20.1.23 | Columnfet100FramerLocal | read-write | current | Local FRM220-ET100 card ET100 Framer setting: 0:ccs-d4 1:cas-esf |
| 1.3.6.1.4.1.4756.20.340.20.1.24 | Columnfet100CrcLocal | read-write | current | Local FRM220-ET100 card CRC setting: 0:disable 1:enable |
| 1.3.6.1.4.1.4756.20.340.20.1.25 | Columnfet100UnusedTimeslotCodeLocal | read-write | current | Local FRM220-ET100 card Unused timeslot code setting: 0:0x7e 1:0xff |
| 1.3.6.1.4.1.4756.20.340.20.1.26 | Columnfet100TimesourceLocal | read-write | current | Local FRM220-ET100 card Timing Source: 0:recovery 1:internal |
| 1.3.6.1.4.1.4756.20.340.20.1.27 | Columnfet100RateLocal | read-write | current | Local FRM220-ET100 card Active Timeslot Numbers: E1 : CCS Mode CAS Mode T1: 1 64K 64K 64K 2 128K 128K 128K 3 192K 192K 192K 4 256K 256K 256K 5 320K 320K 320K 6… |
| 1.3.6.1.4.1.4756.20.340.20.1.28 | Columnfet100TimeslotLocal | read-write | current | Local FRM220-ET100 card Start Timeslot: |
| 1.3.6.1.4.1.4756.20.340.20.1.29 | Columnfet100LbsettingLocal | read-write | current | Local FRM220-ET100 card Loop Back setting: 0:off 1:fiber-side-llb 2:fiber-side-rlb 3:fiber-side-rrlb 5:lan-port-side-llb 6:lan-port-side-rlb 7:lan-port-side-rr… |
| 1.3.6.1.4.1.4756.20.340.20.1.30 | Columnfet100UtpLinkLocal | read-only | current | Local FRM220-ET100 card utp link state: 0:Down 1:Up |
| 1.3.6.1.4.1.4756.20.340.20.1.31 | Columnfet100UtpSpeedSTSLocal | read-only | current | Local FRM220-ET100 card utp speed state: 0:10M 1:100M |
| 1.3.6.1.4.1.4756.20.340.20.1.32 | Columnfet100UtpDuplexSTSLocal | read-only | current | Local FRM220-ET100 card utp duplex status: 0:Half 1:Full |
| 1.3.6.1.4.1.4756.20.340.20.1.33 | Columnfet100UtpNegoLocal | read-write | current | Local FRM220-ET100 card ET100 utp negoiation: 0:Manual 1:Auto |
| 1.3.6.1.4.1.4756.20.340.20.1.34 | Columnfet100UtpSpeedLocal | read-write | current | Local FRM220-ET100 card ET100 utp speed: 0:10M 1:100M |
| 1.3.6.1.4.1.4756.20.340.20.1.35 | Columnfet100UtpDuplexLocal | read-write | current | Local FRM220-ET100 card ET100 utp duplex: 0:Half 1:Full |
| 1.3.6.1.4.1.4756.20.340.20.1.36 | Columnfet100UtpFlowCrlLocal | read-write | current | Local FRM220-ET100 card ET100 utp flow control: 0:Disable 1:Enable |
| 1.3.6.1.4.1.4756.20.340.20.1.37 | Columnfet100HDLCFlowCrlLocal | read-write | current | Local FRM220-ET100 card ET100 HDLC flow control: 0:Disable 1:Enable |
| 1.3.6.1.4.1.4756.20.340.20.1.38 | Columnfet100FxDDLocal | read-only | current | Local FRM220-ET100 card fiber Digital Diagnostic function: 0:No 1:Yes |
| 1.3.6.1.4.1.4756.20.340.20.1.39 | Columnfet100DDVendorLocal | read-only | current | Local FRM220-ET100 card fiber D/D information: Vendor name |
| 1.3.6.1.4.1.4756.20.340.20.1.40 | Columnfet100DDPartNoLocal | read-only | current | Local FRM220-ET100 card fiber D/D information: Vendor part number |
| 1.3.6.1.4.1.4756.20.340.20.1.41 | Columnfet100DDFiberTypeLocal | read-only | current | Local FRM220-ET100 card fiber D/D information: Fiber Type |
| 1.3.6.1.4.1.4756.20.340.20.1.42 | Columnfet100DDWaveLenLocal | read-only | current | Local FRM220-ET100 card fiber D/D information: Wave length |
| 1.3.6.1.4.1.4756.20.340.20.1.43 | Columnfet100DDWaveLen2Local | read-only | current | Local FRM220-ET100 card fiber D/D information: Wave length 2 |
| 1.3.6.1.4.1.4756.20.340.20.1.44 | Columnfet100DDLinkLenLocal | read-only | current | Local FRM220-ET100 card fiber D/D information: Link length |
| 1.3.6.1.4.1.4756.20.340.20.1.45 | Columnfet100DDLenUnitLocal | read-only | current | Local FRM220-ET100 card fiber D/D information: Length Unit |
| 1.3.6.1.4.1.4756.20.340.20.1.46 | Columnfet100DDStatusLocal | read-only | current | Local FRM220-ET100 card fiber D/D information: Status Support |
| 1.3.6.1.4.1.4756.20.340.20.1.47 | Columnfet100DDRxSensLocal | read-only | current | Local FRM220-ET100 card fiber D/D information: Rx Sensitivity |
| 1.3.6.1.4.1.4756.20.340.20.1.48 | Columnfet100DDTxPwrLocal | read-only | current | Local FRM220-ET100 card fiber D/D information: Tx power |
| 1.3.6.1.4.1.4756.20.340.20.1.49 | Columnfet100DDRxPwrLocal | read-only | current | Local FRM220-ET100 card fiber D/D information: Rx power |
| 1.3.6.1.4.1.4756.20.340.20.1.50 | Columnfet100DDTempLocal | read-only | current | Local FRM220-ET100 card fiber D/D information: Temperature in degree C |
| 1.3.6.1.4.1.4756.20.340.20.1.51 | Columnfet100DDPwrMarginLocal | read-only | current | Local FRM220-ET100 card fiber D/D information: Power margin |
| 1.3.6.1.4.1.4756.20.340.20.1.52 | Columnfet100DDPwrLossLocal | read-only | current | Local FRM220-ET100 card fiber D/D information: Power loss |
| 1.3.6.1.4.1.4756.20.341 | Nodefet100RemoteCards | |||
| 1.3.6.1.4.1.4756.20.341.20 | Tablefet100RemoteTable | not-accessible | current | A list of local FRM220-ET100 card entries. The number of entries is fET100-No-L. |
| 1.3.6.1.4.1.4756.20.341.20.1 | Rowfet100RemoteEntry | not-accessible | current | An entry containing management information applicable to a particular local FRM220-ET100 card. |
| 1.3.6.1.4.1.4756.20.341.20.1.1 | Columnfet100ChassisIndexRemote | read-only | current | A unique value for each local card. It is the chassis location number. |
| 1.3.6.1.4.1.4756.20.341.20.1.2 | Columnfet100SlotIndexRemote | read-only | current | A unique value for each local card. It is the slot location number. |
| 1.3.6.1.4.1.4756.20.341.20.1.3 | Columnfet100CardHWVerRemote | read-only | current | Remote FRM220-ET100 card hardware version x.xxx |
| 1.3.6.1.4.1.4756.20.341.20.1.4 | Columnfet100CardFWVerRemote | read-only | current | Remote FRM220-ET100 card firmware version x.xxx |
| 1.3.6.1.4.1.4756.20.341.20.1.5 | Columnfet100CardCPLDVerRemote | read-only | current | Remote FRM220-ET100 card CPLD version x.xxx |
| 1.3.6.1.4.1.4756.20.341.20.1.6 | Columnfet100CardFPGAVerRemote | read-only | current | Remote FRM220-ET100 card FPGA version x.xxx |
| 1.3.6.1.4.1.4756.20.341.20.1.7 | Columnfet100PortResetRemote | read-write | current | Force local FRM220-ET100 card to reset mode: 0:Off 1:Action |
| 1.3.6.1.4.1.4756.20.341.20.1.8 | Columnfet100SetDefaultRemote | read-write | current | Force local FRM220-ET100 card to default status: 0:Off 1:Action |
| 1.3.6.1.4.1.4756.20.341.20.1.9 | Columnfet100PowerLedRemote | read-only | current | Remote FRM220-ET100 card Power led status: 0:Off 1:On 2:Flash |
| 1.3.6.1.4.1.4756.20.341.20.1.10 | Columnfet100SYSLedRemote | read-only | current | Remote FRM220-ET100 card system led status: 0:Off 1:On |
| 1.3.6.1.4.1.4756.20.341.20.1.11 | Columnfet100AlarmLedRemote | read-only | current | Remote FRM220-ET100 card alarm led status: 0:Off 1:On |
| 1.3.6.1.4.1.4756.20.341.20.1.12 | Columnfet100TestLedRemote | read-only | current | Remote FRM220-ET100 card test led status: 0:Off 1:On |
| 1.3.6.1.4.1.4756.20.341.20.1.13 | Columnfet100FxLinkRemote | read-only | current | Remote FRM220-ET100 card fiber link: 0:Down 1:Up |
| 1.3.6.1.4.1.4756.20.341.20.1.14 | Columnfet100FxSignalAppearRemote | read-only | current | Remote FRM220-ET100 card fiber signal appear: 0:Off 1:Have |
| 1.3.6.1.4.1.4756.20.341.20.1.15 | Columnfet100FxSignalLossRemote | read-only | current | Remote FRM220-ET100 card fiber singal loss: 0:Off 1:Have |
| 1.3.6.1.4.1.4756.20.341.20.1.16 | Columnfet100FxSignalRemote | read-only | current | Remote FRM220-ET100 card signal : 0:No 1:Yes |
| 1.3.6.1.4.1.4756.20.341.20.1.17 | Columnfet100FEFRemote | read-only | current | Remote FRM220-ET100 card fiber detected Far End Fault: 0:Off 1:Detected |
| 1.3.6.1.4.1.4756.20.341.20.1.18 | Columnfet100FxTypeRemote | read-only | current | Remote FRM220-ET100 card fiber type: 0:1*9 1:SFP |
| 1.3.6.1.4.1.4756.20.341.20.1.19 | Columnfet100AlsRemote | read-write | current | Remote FRM220-ET100 card Auto Laser Shutdown: 0:disable 1:enable |
| 1.3.6.1.4.1.4756.20.341.20.1.20 | Columnfet100E1T1selRemote | read-write | current | Remote FRM220-ET100 card ET100 Select: 0:e1 1:t1 |
| 1.3.6.1.4.1.4756.20.341.20.1.21 | Columnfet100FullFractionalRemote | read-write | current | Remote FRM220-ET100 card ET100 Full/Fractional: 0:full-e1t1 1:fraction-e1t1 |
| 1.3.6.1.4.1.4756.20.341.20.1.22 | Columnfet100FramerRemote | read-write | current | Remote FRM220-ET100 card ET100 Framer setting: 0:ccs-d4 1:cas-esf |
| 1.3.6.1.4.1.4756.20.341.20.1.23 | Columnfet100CrcRemote | read-write | current | Remote FRM220-ET100 card CRC setting: 0:disable 1:enable |
| 1.3.6.1.4.1.4756.20.341.20.1.24 | Columnfet100UnusedTimeslotCodeRemote | read-write | current | Remote FRM220-ET100 card Unused timeslot code setting: 0:0x7e 1:0xff |
| 1.3.6.1.4.1.4756.20.341.20.1.25 | Columnfet100TimesourceRemote | read-write | current | Remote FRM220-ET100 card Timing Source: 0:recovery 1:internal |
| 1.3.6.1.4.1.4756.20.341.20.1.26 | Columnfet100RateRemote | read-write | current | Remote FRM220-ET100 card Active Timeslot Numbers: E1 : CCS Mode CAS Mode T1: 1 64K 64K 64K 2 128K 128K 128K 3 192K 192K 192K 4 256K 256K 256K 5 320K 320K 320K … |
| 1.3.6.1.4.1.4756.20.341.20.1.27 | Columnfet100TimeslotRemote | read-write | current | Remote FRM220-ET100 card Start Timeslot: |
| 1.3.6.1.4.1.4756.20.341.20.1.28 | Columnfet100LbsettingRemote | read-write | current | Remote FRM220-ET100 card Loop Back setting: 0:off 5:lan-port-side-llb 6:lan-port-side-rlb 7:lan-port-side-rrlb |
| 1.3.6.1.4.1.4756.20.341.20.1.29 | Columnfet100UtpLinkRemote | read-only | current | Remote FRM220-ET100 card utp link state: 0:Down 1:Up |
| 1.3.6.1.4.1.4756.20.341.20.1.30 | Columnfet100UtpSpeedSTSRemote | read-only | current | Remote FRM220-ET100 card utp speed state: 0:10M 1:100M |
| 1.3.6.1.4.1.4756.20.341.20.1.31 | Columnfet100UtpDuplexSTSRemote | read-only | current | Remote FRM220-ET100 card utp duplex status: 0:Half 1:Full |
| 1.3.6.1.4.1.4756.20.341.20.1.32 | Columnfet100UtpNegoRemote | read-write | current | Remote FRM220-ET100 card ET100 utp negoiation: 0:Manual 1:Auto |
| 1.3.6.1.4.1.4756.20.341.20.1.33 | Columnfet100UtpSpeedRemote | read-write | current | Remote FRM220-ET100 card ET100 utp speed: 0:10M 1:100M |
| 1.3.6.1.4.1.4756.20.341.20.1.34 | Columnfet100UtpDuplexRemote | read-write | current | Remote FRM220-ET100 card ET100 utp duplex: 0:Half 1:Full |
| 1.3.6.1.4.1.4756.20.341.20.1.35 | Columnfet100UtpFlowCrlRemote | read-write | current | Remote FRM220-ET100 card ET100 utp flow control: 0:Disable 1:Enable |
| 1.3.6.1.4.1.4756.20.341.20.1.36 | Columnfet100HDLCFlowCrlRemote | read-write | current | Remote FRM220-ET100 card ET100 HDLC flow control: 0:Disable 1:Enable |
| 1.3.6.1.4.1.4756.20.341.20.1.37 | Columnfet100FxDDRemote | read-only | current | Remote FRM220-ET100 card fiber Digital Diagnostic function: 0:No 1:Yes |
| 1.3.6.1.4.1.4756.20.341.20.1.38 | Columnfet100DDVendorRemote | read-only | current | Remote FRM220-ET100 card fiber D/D information: Vendor name |
| 1.3.6.1.4.1.4756.20.341.20.1.39 | Columnfet100DDPartNoRemote | read-only | current | Remote FRM220-ET100 card fiber D/D information: Vendor part number |
| 1.3.6.1.4.1.4756.20.341.20.1.40 | Columnfet100DDFiberTypeRemote | read-only | current | Remote FRM220-ET100 card fiber D/D information: Fiber Type |
| 1.3.6.1.4.1.4756.20.341.20.1.41 | Columnfet100DDWaveLenRemote | read-only | current | Remote FRM220-ET100 card fiber D/D information: Wave length |
| 1.3.6.1.4.1.4756.20.341.20.1.42 | Columnfet100DDWaveLen2Remote | read-only | current | Remote FRM220-ET100 card fiber D/D information: Wave length 2 |
| 1.3.6.1.4.1.4756.20.341.20.1.43 | Columnfet100DDLinkLenRemote | read-only | current | Remote FRM220-ET100 card fiber D/D information: Link length |
| 1.3.6.1.4.1.4756.20.341.20.1.44 | Columnfet100DDLenUnitRemote | read-only | current | Remote FRM220-ET100 card fiber D/D information: Length Unit |
| 1.3.6.1.4.1.4756.20.341.20.1.45 | Columnfet100DDStatusRemote | read-only | current | Remote FRM220-ET100 card fiber D/D information: Status Support |
| 1.3.6.1.4.1.4756.20.341.20.1.46 | Columnfet100DDRxSensRemote | read-only | current | Remote FRM220-ET100 card fiber D/D information: Rx Sensitivity |
| 1.3.6.1.4.1.4756.20.341.20.1.47 | Columnfet100DDTxPwrRemote | read-only | current | Remote FRM220-ET100 card fiber D/D information: Tx power |
| 1.3.6.1.4.1.4756.20.341.20.1.48 | Columnfet100DDRxPwrRemote | read-only | current | Remote FRM220-ET100 card fiber D/D information: Rx power |
| 1.3.6.1.4.1.4756.20.341.20.1.49 | Columnfet100DDTempRemote | read-only | current | Remote FRM220-ET100 card fiber D/D information: Temperature in degree C |
| 1.3.6.1.4.1.4756.20.341.20.1.50 | Columnfet100DDPwrMarginRemote | read-only | current | Remote FRM220-ET100 card fiber D/D information: Power margin |
| 1.3.6.1.4.1.4756.20.341.20.1.51 | Columnfet100DDPwrLossRemote | read-only | current | Remote FRM220-ET100 card fiber D/D information: Power loss |
| 1.3.6.1.4.1.4756.20.350 | Nodef8E1LocalCards | |||
| 1.3.6.1.4.1.4756.20.350.20 | Tablef8E1LocalTable | not-accessible | current | A list of local FRM220-8E1-ET100 series card entries. The number of entries is f8E1-No-L. |
| 1.3.6.1.4.1.4756.20.350.20.1 | Rowf8E1LocalEntry | not-accessible | current | An entry containing management information applicable to a particular local FRM220-8E1 series card. |
| 1.3.6.1.4.1.4756.20.350.20.1.1 | Columnfa8e1et100ChassisIndexLocal | read-only | current | A unique value for each card. It starts from 0 to 9 contiguously. |
| 1.3.6.1.4.1.4756.20.350.20.1.2 | Columnfa8e1et100SlotIndexLocal | read-only | current | A unique value for each card. It starts from 1 to 20 contiguously. |
| 1.3.6.1.4.1.4756.20.350.20.1.3 | Columnfa8e1et100CardHWVerLocal | read-only | current | 8E1-ET100(T/S) Series card hardware version x.xxx |
| 1.3.6.1.4.1.4756.20.350.20.1.4 | Columnfa8e1et100CardFWVerLocal | read-only | current | 8E1-ET100(T/S) Series card firmware version x.xxx |
| 1.3.6.1.4.1.4756.20.350.20.1.5 | Columnfa8e1et100CardCPLDVerLocal | read-only | current | 8E1-ET100(T/S) Series card CPLD version x.xxx |
| 1.3.6.1.4.1.4756.20.350.20.1.6 | Columnfa8e1et100CardFPGAVerLocal | read-only | current | 8E1-ET100(T/S) Series card FPGA version x.xxx |
| 1.3.6.1.4.1.4756.20.350.20.1.7 | Columnfa8e1et100ModelLocal | read-only | current | Card Type: 0:8E1-ET100T 1:8E1-ET100S |
| 1.3.6.1.4.1.4756.20.350.20.1.8 | Columnfa8e1et100SystemStatusLocal | read-only | current | 8E1-ET100(T/S) Series card system status: 0:Normal 1:Alarm |
| 1.3.6.1.4.1.4756.20.350.20.1.9 | Columnfa8e1et100DeviceActiveLocal | read-write | current | 8E1-ET100(T/S) Series card active: 0:Disable 1:Enable |
| 1.3.6.1.4.1.4756.20.350.20.1.10 | Columnfa8e1et100SetToDefaultLocal | read-write | current | 8E1-ET100(T/S) Series card port set to default: 0:Off 1:Trigger |
| 1.3.6.1.4.1.4756.20.350.20.1.11 | Columnfa8e1et100E1Ch1SingalLocal | read-only | current | 8E1-ET100(T/S) Series card E1 channel 1 signal status: 0:Singal Loss 1:Normal |
| 1.3.6.1.4.1.4756.20.350.20.1.12 | Columnfa8e1et100E1Ch2SingalLocal | read-only | current | 8E1-ET100(T/S) Series card E1 channel 2 signal status: 0:Singal Loss 1:Normal |
| 1.3.6.1.4.1.4756.20.350.20.1.13 | Columnfa8e1et100E1Ch3SingalLocal | read-only | current | 8E1-ET100(T/S) Series card E1 channel 3 signal status: 0:Singal Loss 1:Normal |
| 1.3.6.1.4.1.4756.20.350.20.1.14 | Columnfa8e1et100E1Ch4SingalLocal | read-only | current | 8E1-ET100(T/S) Series card E1 channel 4 signal status: 0:Singal Loss 1:Normal |
| 1.3.6.1.4.1.4756.20.350.20.1.15 | Columnfa8e1et100E1Ch5SingalLocal | read-only | current | 8E1-ET100(T/S) Series card E1 channel 5 signal status: 0:Singal Loss 1:Normal |
| 1.3.6.1.4.1.4756.20.350.20.1.16 | Columnfa8e1et100E1Ch6SingalLocal | read-only | current | 8E1-ET100(T/S) Series card E1 channel 6 signal status: 0:Singal Loss 1:Normal |
| 1.3.6.1.4.1.4756.20.350.20.1.17 | Columnfa8e1et100E1Ch7SingalLocal | read-only | current | 8E1-ET100(T/S) Series card E1 channel 7 signal status: 0:Singal Loss 1:Normal |
| 1.3.6.1.4.1.4756.20.350.20.1.18 | Columnfa8e1et100E1Ch8SingalLocal | read-only | current | 8E1-ET100(T/S) Series card E1 channel 8 signal status: 0:Singal Loss 1:Normal |
| 1.3.6.1.4.1.4756.20.350.20.1.19 | Columnfa8e1et100E1Ch1SyncLocal | read-only | current | 8E1-ET100(T/S) Series card E1 channel 1 sync status: 0:Sync Loss 1:Sync |
| 1.3.6.1.4.1.4756.20.350.20.1.20 | Columnfa8e1et100E1Ch2SyncLocal | read-only | current | 8E1-ET100(T/S) Series card E1 channel 2 sync status: 0:Sync Loss 1:Sync |
| 1.3.6.1.4.1.4756.20.350.20.1.21 | Columnfa8e1et100E1Ch3SyncLocal | read-only | current | 8E1-ET100(T/S) Series card E1 channel 3 sync status: 0:Sync Loss 1:Sync |
| 1.3.6.1.4.1.4756.20.350.20.1.22 | Columnfa8e1et100E1Ch4SyncLocal | read-only | current | 8E1-ET100(T/S) Series card E1 channel 4 sync status: 0:Sync Loss 1:Sync |
| 1.3.6.1.4.1.4756.20.350.20.1.23 | Columnfa8e1et100E1Ch5SyncLocal | read-only | current | 8E1-ET100(T/S) Series card E1 channel 5 sync status: 0:Sync Loss 1:Sync |
| 1.3.6.1.4.1.4756.20.350.20.1.24 | Columnfa8e1et100E1Ch6SyncLocal | read-only | current | 8E1-ET100(T/S) Series card E1 channel 6 sync status: 0:Sync Loss 1:Sync |
| 1.3.6.1.4.1.4756.20.350.20.1.25 | Columnfa8e1et100E1Ch7SyncLocal | read-only | current | 8E1-ET100(T/S) Series card E1 channel 7 sync status: 0:Sync Loss 1:Sync |
| 1.3.6.1.4.1.4756.20.350.20.1.26 | Columnfa8e1et100E1Ch8SyncLocal | read-only | current | 8E1-ET100(T/S) Series card E1 channel 8 sync status: 0:Sync Loss 1:Sync |
| 1.3.6.1.4.1.4756.20.350.20.1.27 | Columnfa8e1et100E1Ch1RecvAISLocal | read-only | current | 8E1-ET100(T/S) Series card E1 channel 1 receive AIS status: 0:No 1:Yes |
| 1.3.6.1.4.1.4756.20.350.20.1.28 | Columnfa8e1et100E1Ch2RecvAISLocal | read-only | current | 8E1-ET100(T/S) Series card E1 channel 2 receive AIS status: 0:No 1:Yes |
| 1.3.6.1.4.1.4756.20.350.20.1.29 | Columnfa8e1et100E1Ch3RecvAISLocal | read-only | current | 8E1-ET100(T/S) Series card E1 channel 3 receive AIS status: 0:No 1:Yes |
| 1.3.6.1.4.1.4756.20.350.20.1.30 | Columnfa8e1et100E1Ch4RecvAISLocal | read-only | current | 8E1-ET100(T/S) Series card E1 channel 4 receive AIS status: 0:No 1:Yes |
| 1.3.6.1.4.1.4756.20.350.20.1.31 | Columnfa8e1et100E1Ch5RecvAISLocal | read-only | current | 8E1-ET100(T/S) Series card E1 channel 5 receive AIS status: 0:No 1:Yes |
| 1.3.6.1.4.1.4756.20.350.20.1.32 | Columnfa8e1et100E1Ch6RecvAISLocal | read-only | current | 8E1-ET100(T/S) Series card E1 channel 6 receive AIS status: 0:No 1:Yes |
| 1.3.6.1.4.1.4756.20.350.20.1.33 | Columnfa8e1et100E1Ch7RecvAISLocal | read-only | current | 8E1-ET100(T/S) Series card E1 channel 7 receive AIS status: 0:No 1:Yes |
| 1.3.6.1.4.1.4756.20.350.20.1.34 | Columnfa8e1et100E1Ch8RecvAISLocal | read-only | current | 8E1-ET100(T/S) Series card E1 channel 8 receive AIS status: 0:No 1:Yes |
| 1.3.6.1.4.1.4756.20.350.20.1.35 | Columnfa8e1et100E1Ch1ConnTypeLocal | read-only | current | 8E1-ET100(T/S) Series card E1 channel 1 connector type: 0:RJ-48C 1:BNC |
| 1.3.6.1.4.1.4756.20.350.20.1.36 | Columnfa8e1et100E1Ch2ConnTypeLocal | read-only | current | 8E1-ET100(T/S) Series card E1 channel 2 connector type: 0:RJ-48C 1:BNC |
| 1.3.6.1.4.1.4756.20.350.20.1.37 | Columnfa8e1et100E1Ch3ConnTypeLocal | read-only | current | 8E1-ET100(T/S) Series card E1 channel 3 connector type: 0:RJ-48C 1:BNC |
| 1.3.6.1.4.1.4756.20.350.20.1.38 | Columnfa8e1et100E1Ch4ConnTypeLocal | read-only | current | 8E1-ET100(T/S) Series card E1 channel 4 connector type: 0:RJ-48C 1:BNC |
| 1.3.6.1.4.1.4756.20.350.20.1.39 | Columnfa8e1et100E1Ch5ConnTypeLocal | read-only | current | 8E1-ET100(T/S) Series card E1 channel 5 connector type: 0:RJ-48C 1:BNC |
| 1.3.6.1.4.1.4756.20.350.20.1.40 | Columnfa8e1et100E1Ch6ConnTypeLocal | read-only | current | 8E1-ET100(T/S) Series card E1 channel 6 connector type: 0:RJ-48C 1:BNC |
| 1.3.6.1.4.1.4756.20.350.20.1.41 | Columnfa8e1et100E1Ch7ConnTypeLocal | read-only | current | 8E1-ET100(T/S) Series card E1 channel 7 connector type: 0:RJ-48C 1:BNC |
| 1.3.6.1.4.1.4756.20.350.20.1.42 | Columnfa8e1et100E1Ch8ConnTypeLocal | read-only | current | 8E1-ET100(T/S) Series card E1 channel 8 connector type: 0:RJ-48C 1:BNC |
| 1.3.6.1.4.1.4756.20.350.20.1.43 | Columnfa8e1et100E1Ch1RAILocal | read-only | current | 8E1-ET100(T/S) Series card E1 channel 1 RAI status: 0:No 1:Yes |
| 1.3.6.1.4.1.4756.20.350.20.1.44 | Columnfa8e1et100E1Ch2RAILocal | read-only | current | 8E1-ET100(T/S) Series card E1 channel 2 RAI status: 0:No 1:Yes |
| 1.3.6.1.4.1.4756.20.350.20.1.45 | Columnfa8e1et100E1Ch3RAILocal | read-only | current | 8E1-ET100(T/S) Series card E1 channel 3 RAI status: 0:No 1:Yes |
| 1.3.6.1.4.1.4756.20.350.20.1.46 | Columnfa8e1et100E1Ch4RAILocal | read-only | current | 8E1-ET100(T/S) Series card E1 channel 4 RAI status: 0:No 1:Yes |
| 1.3.6.1.4.1.4756.20.350.20.1.47 | Columnfa8e1et100E1Ch5RAILocal | read-only | current | 8E1-ET100(T/S) Series card E1 channel 5 RAI status: 0:No 1:Yes |
| 1.3.6.1.4.1.4756.20.350.20.1.48 | Columnfa8e1et100E1Ch6RAILocal | read-only | current | 8E1-ET100(T/S) Series card E1 channel 6 RAI status: 0:No 1:Yes |
| 1.3.6.1.4.1.4756.20.350.20.1.49 | Columnfa8e1et100E1Ch7RAILocal | read-only | current | 8E1-ET100(T/S) Series card E1 channel 7 RAI status: 0:No 1:Yes |
| 1.3.6.1.4.1.4756.20.350.20.1.50 | Columnfa8e1et100E1Ch8RAILocal | read-only | current | 8E1-ET100(T/S) Series card E1 channel 8 RAI status: 0:No 1:Yes |
| 1.3.6.1.4.1.4756.20.350.20.1.51 | Columnfa8e1et100E1Ch1LOMFLocal | read-only | current | 8E1-ET100(T/S) Series card E1 channel 1 LOMF status: 0:No 1:Yes |
| 1.3.6.1.4.1.4756.20.350.20.1.52 | Columnfa8e1et100E1Ch2LOMFLocal | read-only | current | 8E1-ET100(T/S) Series card E1 channel 2 LOMF status: 0:No 1:Yes |
| 1.3.6.1.4.1.4756.20.350.20.1.53 | Columnfa8e1et100E1Ch3LOMFLocal | read-only | current | 8E1-ET100(T/S) Series card E1 channel 3 LOMF status: 0:No 1:Yes |
| 1.3.6.1.4.1.4756.20.350.20.1.54 | Columnfa8e1et100E1Ch4LOMFLocal | read-only | current | 8E1-ET100(T/S) Series card E1 channel 4 LOMF status: 0:No 1:Yes |
| 1.3.6.1.4.1.4756.20.350.20.1.55 | Columnfa8e1et100E1Ch5LOMFLocal | read-only | current | 8E1-ET100(T/S) Series card E1 channel 5 LOMF status: 0:No 1:Yes |
| 1.3.6.1.4.1.4756.20.350.20.1.56 | Columnfa8e1et100E1Ch6LOMFLocal | read-only | current | 8E1-ET100(T/S) Series card E1 channel 6 LOMF status: 0:No 1:Yes |
| 1.3.6.1.4.1.4756.20.350.20.1.57 | Columnfa8e1et100E1Ch7LOMFLocal | read-only | current | 8E1-ET100(T/S) Series card E1 channel 7 LOMF status: 0:No 1:Yes |
| 1.3.6.1.4.1.4756.20.350.20.1.58 | Columnfa8e1et100E1Ch8LOMFLocal | read-only | current | 8E1-ET100(T/S) Series card E1 channel 8 LOMF status: 0:No 1:Yes |
| 1.3.6.1.4.1.4756.20.350.20.1.59 | Columnfa8e1et100E1Ch1ActiveLocal | read-only | current | 8E1-ET100(T/S) Series card E1 channel 1 active status: 0:Inactive 1:Active |
| 1.3.6.1.4.1.4756.20.350.20.1.60 | Columnfa8e1et100E1Ch2ActiveLocal | read-only | current | 8E1-ET100(T/S) Series card E1 channel 2 active status: 0:Inactive 1:Active |
| 1.3.6.1.4.1.4756.20.350.20.1.61 | Columnfa8e1et100E1Ch3ActiveLocal | read-only | current | 8E1-ET100(T/S) Series card E1 channel 3 active status: 0:Inactive 1:Active |
| 1.3.6.1.4.1.4756.20.350.20.1.62 | Columnfa8e1et100E1Ch4ActiveLocal | read-only | current | 8E1-ET100(T/S) Series card E1 channel 4 active status: 0:Inactive 1:Active |
| 1.3.6.1.4.1.4756.20.350.20.1.63 | Columnfa8e1et100E1Ch5ActiveLocal | read-only | current | 8E1-ET100(T/S) Series card E1 channel 5 active status: 0:Inactive 1:Active |
| 1.3.6.1.4.1.4756.20.350.20.1.64 | Columnfa8e1et100E1Ch6ActiveLocal | read-only | current | 8E1-ET100(T/S) Series card E1 channel 6 active status: 0:Inactive 1:Active |
| 1.3.6.1.4.1.4756.20.350.20.1.65 | Columnfa8e1et100E1Ch7ActiveLocal | read-only | current | 8E1-ET100(T/S) Series card E1 channel 7 active status: 0:Inactive 1:Active |
| 1.3.6.1.4.1.4756.20.350.20.1.66 | Columnfa8e1et100E1Ch8ActiveLocal | read-only | current | 8E1-ET100(T/S) Series card E1 channel 8 active status: 0:Inactive 1:Active |
| 1.3.6.1.4.1.4756.20.350.20.1.67 | Columnfa8e1et100E1Ch1LoopBackLocal | read-write | current | 8E1-ET100(T/S) Series card port E1 channel 1 loop back: 0:Off 2:RLB (Max used 4 channels) |
| 1.3.6.1.4.1.4756.20.350.20.1.68 | Columnfa8e1et100E1Ch2LoopBackLocal | read-write | current | 8E1-ET100(T/S) Series card port E1 channel 2 loop back: 0:Off 2:RLB (Max used 4 channels) |
| 1.3.6.1.4.1.4756.20.350.20.1.69 | Columnfa8e1et100E1Ch3LoopBackLocal | read-write | current | 8E1-ET100(T/S) Series card port E1 channel 3 loop back: 0:Off 2:RLB (Max used 4 channels) |
| 1.3.6.1.4.1.4756.20.350.20.1.70 | Columnfa8e1et100E1Ch4LoopBackLocal | read-write | current | 8E1-ET100(T/S) Series card port E1 channel 4 loop back: 0:Off 2:RLB (Max used 4 channels) |
| 1.3.6.1.4.1.4756.20.350.20.1.71 | Columnfa8e1et100E1Ch5LoopBackLocal | read-write | current | 8E1-ET100(T/S) Series card port E1 channel 5 loop back: 0:Off 2:RLB (Max used 4 channels) |
| 1.3.6.1.4.1.4756.20.350.20.1.72 | Columnfa8e1et100E1Ch6LoopBackLocal | read-write | current | 8E1-ET100(T/S) Series card port E1 channel 6 loop back: 0:Off 2:RLB (Max used 4 channels) |
| 1.3.6.1.4.1.4756.20.350.20.1.73 | Columnfa8e1et100E1Ch7LoopBackLocal | read-write | current | 8E1-ET100(T/S) Series card port E1 channel 7 loop back: 0:Off 2:RLB (Max used 4 channels) |
| 1.3.6.1.4.1.4756.20.350.20.1.74 | Columnfa8e1et100E1Ch8LoopBackLocal | read-write | current | 8E1-ET100(T/S) Series card port E1 channel 8 loop back: 0:Off 2:RLB (Max used 4 channels) |
| 1.3.6.1.4.1.4756.20.350.20.1.75 | Columnfa8e1et100FxLinkLocal | read-only | current | 8E1-ET100S Series card Fiber siganl detect status: 0:Down or Fiber unplugged 1:Up or Singal detected |
| 1.3.6.1.4.1.4756.20.350.20.1.76 | Columnfa8e1et100FxLaserLocal | read-only | current | 8E1-ET100S Series card laser status: 0:Normal 1:Error |
| 1.3.6.1.4.1.4756.20.350.20.1.77 | Columnfa8e1et100FxActiveLocal | read-write | current | 8E1-ET100S Series card Fiber active: 0:Inactive 1:Active |
| 1.3.6.1.4.1.4756.20.350.20.1.78 | Columnfa8e1et100FxLaserOutputLocal | read-write | current | 8E1-ET100S Series card laser output: 0:disable 1:Enable |
| 1.3.6.1.4.1.4756.20.350.20.1.79 | Columnfa8e1et100FxOpModeLocal | read-write | current | 8E1-ET100S Series card operation mode: 0:Switch 1:Convert |
| 1.3.6.1.4.1.4756.20.350.20.1.80 | Columnfa8e1et100UtpLinkLocal | read-only | current | 8E1-ET100T Series card UTP link status: 0:Link Down 1:Link Up |
| 1.3.6.1.4.1.4756.20.350.20.1.81 | Columnfa8e1et100UtpStatusLocal | read-only | current | 8E1-ET100T Series card UTP link mode status: 0:None, Maybe link down 1:Link at 10Mbps, Half duplex 2:Link at 10Mbps, Full duplex 3:Link at 100Mbps, Half duplex… |
| 1.3.6.1.4.1.4756.20.350.20.1.82 | Columnfa8e1et100UtpFlowCtrlStsLocal | read-only | current | 8E1-ET100T Series card UTP flow control status: 0:Disable 1:Enable |
| 1.3.6.1.4.1.4756.20.350.20.1.83 | Columnfa8e1et100UtpModeLocal | read-write | current | 8E1-ET100T Series card UTP mode: 0:Disable 1:Enable and autoNegotiation 3:Enable and force to 10Mbps, Half duplex 4:Enable and force to 10Mbps, Full duplex 5:E… |
| 1.3.6.1.4.1.4756.20.350.20.1.84 | Columnfa8e1et100UtpFlowCtrlLocal | read-write | current | 8E1-ET100T Series card UTP flow control: 0:Disable 1:Enable |
| 1.3.6.1.4.1.4756.20.350.20.1.85 | Columnfa8e1et100SpeedLimitLocal | read-write | current | 8E1-ET100(T/S) Series card speed limit: Limited = this value * 32Kbps, this value is restricted to 0 ~ 3125, 0 to disable |
| 1.3.6.1.4.1.4756.20.350.20.1.86 | Columnfa8e1et100VlanAwareLocal | read-write | current | 8E1-ET100(T/S) Series card 802.1q VLAN tag aware: 0:Disable 1:Enable |
| 1.3.6.1.4.1.4756.20.350.20.1.87 | Columnfa8e1et100VlanIDLocal | read-write | current | 8E1-ET100(T/S) Series card VLAN ID: The ID is restricted to 1 ~ 4094 |
| 1.3.6.1.4.1.4756.20.350.20.1.88 | Columnfa8e1et100RemoteDeviceLocal | read-only | current | FRM220A-8E1 Series card remote device status: 0:Link Down 1:Link Up |
| 1.3.6.1.4.1.4756.20.350.20.1.89 | Columnfa8e1et100RemotePowerLocal | read-only | current | 8E1-ET100(T/S) Series card remote device power status: 0:Normal 1:Power off |
| 1.3.6.1.4.1.4756.20.350.20.1.90 | Columnfa8e1et100TimingSourceLocal | read-write | current | 8E1-ET100(T/S) Series card clock: 0:Internal oscillatro 1:Recovery from E1 channel 1 2:Recovery from E1 channel 2 3:Recovery from E1 channel 3 4:Recovery from … |
| 1.3.6.1.4.1.4756.20.350.20.1.91 | Columnfa8e1et100FCSofGFPLocal | read-write | current | 8E1-ET100(T/S) Series card FCS of GFP: 0:Disable 1:Enable |
| 1.3.6.1.4.1.4756.20.350.20.1.92 | Columnfa8e1et100AutoChAdjustLocal | read-write | current | 8E1-ET100(T/S) Series card auto channel Bdjust: 0:Disable 1:Enable |
| 1.3.6.1.4.1.4756.20.350.20.1.93 | Columnfa8e1et100PayloadScrambleLocal | read-write | current | 8E1-ET100(T/S) Series card payload scramble: 0:Disable 1:Enable |
| 1.3.6.1.4.1.4756.20.350.20.1.94 | Columnfa8e1et100FailoverLocal | read-write | current | 8E1-ET100(T/S) Series card failover: 0:Disable 1:Enable |
| 1.3.6.1.4.1.4756.20.350.20.1.95 | Columnfa8e1et100LOMLocal | read-only | current | 8E1-ET100(T/S) Series card LOM status: 0:No 1:Yes |
| 1.3.6.1.4.1.4756.20.350.20.1.96 | Columnfa8e1et100SQMLocal | read-only | current | 8E1-ET100(T/S) Series card SQM status: 0:No 1:Yes |
| 1.3.6.1.4.1.4756.20.350.20.1.97 | Columnfa8e1et100CRCLocal | read-only | current | 8E1-ET100(T/S) Series card CRC status: 0:No 1:Yes |
| 1.3.6.1.4.1.4756.20.350.20.1.98 | Columnfa8e1et100LOALocal | read-only | current | 8E1-ET100(T/S) Series card LOA status: 0:No 1:Yes |
| 1.3.6.1.4.1.4756.20.350.20.1.99 | Columnfa8e1et100LFDLocal | read-only | current | 8E1-ET100(T/S) Series card LFD status: 0:No 1:Yes |
| 1.3.6.1.4.1.4756.20.350.20.1.100 | Columnfa8e1et100DDTOLocal | read-only | current | 8E1-ET100(T/S) Series card DDTO status: 0:No 1:Yes |
| 1.3.6.1.4.1.4756.20.350.20.1.101 | Columnfa8e1et100VcatMember1Local | read-write | current | 8E1-ET100(T/S) Series card VACT member 0: 0:Disable 1:Enable |
| 1.3.6.1.4.1.4756.20.350.20.1.102 | Columnfa8e1et100VcatMember2Local | read-write | current | 8E1-ET100(T/S) Series card VACT member 1: 0:Disable 1:Enable |
| 1.3.6.1.4.1.4756.20.350.20.1.103 | Columnfa8e1et100VcatMember3Local | read-write | current | 8E1-ET100(T/S) Series card VACT member 3: 0:Disable 1:Enable |
| 1.3.6.1.4.1.4756.20.350.20.1.104 | Columnfa8e1et100VcatMember4Local | read-write | current | 8E1-ET100(T/S) Series card VACT member 4: 0:Disable 1:Enable |
| 1.3.6.1.4.1.4756.20.350.20.1.105 | Columnfa8e1et100VcatMember5Local | read-write | current | 8E1-ET100(T/S) Series card VACT member 5: 0:Disable 1:Enable |
| 1.3.6.1.4.1.4756.20.350.20.1.106 | Columnfa8e1et100VcatMember6Local | read-write | current | 8E1-ET100(T/S) Series card VACT member 6: 0:Disable 1:Enable |
| 1.3.6.1.4.1.4756.20.350.20.1.107 | Columnfa8e1et100VcatMember7Local | read-write | current | 8E1-ET100(T/S) Series card VACT member 7: 0:Disable 1:Enable |
| 1.3.6.1.4.1.4756.20.350.20.1.108 | Columnfa8e1et100VcatMember8Local | read-write | current | 8E1-ET100(T/S) Series card VACT member 8: 0:Disable 1:Enable |
| 1.3.6.1.4.1.4756.20.350.20.1.109 | Columnfa8e1et100SnmpChannel1Local | read-write | current | 8E1-ET100(T/S) Series card SNMP channel 0: 0:No use 1:Use |
| 1.3.6.1.4.1.4756.20.350.20.1.110 | Columnfa8e1et100SnmpChannel2Local | read-write | current | 8E1-ET100(T/S) Series card SNMP channel 1: 0:No use 1:Use |
| 1.3.6.1.4.1.4756.20.350.20.1.111 | Columnfa8e1et100SnmpChannel3Local | read-write | current | 8E1-ET100(T/S) Series card SNMP channel 3: 0:No use 1:Use |
| 1.3.6.1.4.1.4756.20.350.20.1.112 | Columnfa8e1et100SnmpChannel4Local | read-write | current | 8E1-ET100(T/S) Series card SNMP channel 4: 0:No use 1:Use |
| 1.3.6.1.4.1.4756.20.350.20.1.113 | Columnfa8e1et100ErrSecLocal | read-only | current | 8E1-ET100(T/S) Series card, errored seconds of BERT result. |
| 1.3.6.1.4.1.4756.20.350.20.1.114 | Columnfa8e1et100ErrFreeSecLocal | read-only | current | 8E1-ET100(T/S) Series card, errored free seconds of BERT result. |
| 1.3.6.1.4.1.4756.20.350.20.1.115 | Columnfa8e1et100ServErrSecLocal | read-only | current | 8E1-ET100(T/S) Series card, severely errored seconds of BERT result. |
| 1.3.6.1.4.1.4756.20.350.20.1.116 | Columnfa8e1et100BertFunctionLocal | read-write | current | 8E1-ET100(T/S) Series card bert function: 0:Disable 1:Enable |
| 1.3.6.1.4.1.4756.20.350.20.1.117 | Columnfa8e1et100ClrBertDataLocal | read-write | current | 8E1-ET100(T/S) Series card bert data clear: 0:Normal 1:Clear |
| 1.3.6.1.4.1.4756.20.350.20.1.118 | Columnfa8e1et100BertE1ChannelLocal | read-write | current | 8E1-ET100(T/S) Series card bert E1 channel number: 0:E1 channel 1 1:E1 channel 2 2:E1 channel 3 3:E1 channel 4 4:E1 channel 5 5:E1 channel 6 6:E1 channel 7 7:E… |
| 1.3.6.1.4.1.4756.20.350.20.1.119 | Columnfa8e1et100RmonFunctionLocal | read-write | current | 8E1-ET100(T/S) Series RMON function : 0:Disable 1:Enable |
| 1.3.6.1.4.1.4756.20.350.20.1.120 | Columnfa8e1et100RmonTxLocal | read-only | current | 8E1-ET100(T/S) Series card RMON Tx counter. |
| 1.3.6.1.4.1.4756.20.350.20.1.121 | Columnfa8e1et100RmonRxLocal | read-only | current | 8E1-ET100(T/S) Series card RMON Rx counter. |
| 1.3.6.1.4.1.4756.20.350.20.1.122 | Columnfa8e1et100ClrRmonTxLocal | read-write | current | 8E1-ET100(T/S) Series card clear RMON Tx counter: 0:Normal 1:Clear |
| 1.3.6.1.4.1.4756.20.350.20.1.123 | Columnfa8e1et100ClrRmonRxLocal | read-write | current | 8E1-ET100(T/S) Series card clear RMON Rx counter: 0:Normal 1:Clear |
| 1.3.6.1.4.1.4756.20.350.20.1.124 | Columnfa8e1et100SfpLocal | read-only | current | 8E1-ET100(T/S) Series card, SFP existed: 0:No 1:Yes |
| 1.3.6.1.4.1.4756.20.350.20.1.125 | Columnfa8e1et100SfpVendorLocal | read-only | current | 8E1-ET100(T/S) Series card, Vendor name of SFP. |
| 1.3.6.1.4.1.4756.20.350.20.1.126 | Columnfa8e1et100SfpPartNoLocal | read-only | current | 8E1-ET100(T/S) Series card, Vendor part number of SFP. |
| 1.3.6.1.4.1.4756.20.350.20.1.127 | Columnfa8e1et100SfpFiberTypeLocal | read-only | current | 8E1-ET100(T/S) Series card, Fiber Type of SFP. |
| 1.3.6.1.4.1.4756.20.350.20.1.128 | Columnfa8e1et100SfpTxWaveLenLocal | read-only | current | 8E1-ET100(T/S) Series card, Tx Wave length of SFP. |
| 1.3.6.1.4.1.4756.20.350.20.1.129 | Columnfa8e1et100SfpRxWaveLenLocal | read-only | current | 8E1-ET100(T/S) Series card, Rx Wave length of SFP. |
| 1.3.6.1.4.1.4756.20.350.20.1.130 | Columnfa8e1et100SfpLinkLenLocal | read-only | current | 8E1-ET100(T/S) Series card, Link length of SFP. |
| 1.3.6.1.4.1.4756.20.350.20.1.131 | Columnfa8e1et100SfpModelIDLocal | read-only | current | 8E1-ET100(T/S) Series card, model ID of SFP. |
| 1.3.6.1.4.1.4756.20.350.20.1.132 | Columnfa8e1et100SfpVersionLocal | read-only | current | 8E1-ET100(T/S) Series card, the version of SFP. |
| 1.3.6.1.4.1.4756.20.350.20.1.133 | Columnfa8e1et100SfpModelTypeLocal | read-only | current | 8E1-ET100(T/S) Series card, model type of SFP. |
| 1.3.6.1.4.1.4756.20.350.20.1.134 | Columnfa8e1et100DDInformationLocal | read-only | current | 8E1-ET100(T/S) Series card, D/D information of SFP Supported: 0:No, 1:Yes |
| 1.3.6.1.4.1.4756.20.350.20.1.135 | Columnfa8e1et100DDRxSensLocal | read-only | current | 8E1-ET100(T/S) Series card, Sensitivity of D/D information. |
| 1.3.6.1.4.1.4756.20.350.20.1.136 | Columnfa8e1et100DDTxPowerLocal | read-only | current | 8E1-ET100(T/S) Series card, Tx power of D/D information. |
| 1.3.6.1.4.1.4756.20.350.20.1.137 | Columnfa8e1et100DDRxPowerLocal | read-only | current | 8E1-ET100(T/S) Series card, Rx power of D/D information. |
| 1.3.6.1.4.1.4756.20.350.20.1.138 | Columnfa8e1et100DDTempLocal | read-only | current | 8E1-ET100(T/S) Series card, Temperature of D/D information in degree C. |
| 1.3.6.1.4.1.4756.20.350.20.1.139 | Columnfa8e1et100DDBiasLocal | read-only | current | 8E1-ET100(T/S) Series card, BIAS of D/D information. |
| 1.3.6.1.4.1.4756.20.350.20.1.140 | Columnfa8e1et100DDVoltageLocal | read-only | current | 8E1-ET100(T/S) Series card, Voltage of D/D information. |
| 1.3.6.1.4.1.4756.20.350.20.1.141 | Columnfa8e1et100ChannelDefectLocal | read-write | current | 8E1-ET100(T/S) Series card Channel Defect: 0:Disable 4:1E-4 6:1E-6 |
| 1.3.6.1.4.1.4756.20.350.20.1.142 | Columnfa8e1et100LoopDetectionLocal | read-write | current | 8E1-ET100(T/S) Series card Loop Detection: 0:Disable 1:Enable |
| 1.3.6.1.4.1.4756.20.350.20.1.143 | Columnfa8e1et100LoopCh1Local | read-only | current | 8E1-ET100(T/S) Series card E1 channel 1 Loop Check State: 0:No 1:Yes |
| 1.3.6.1.4.1.4756.20.350.20.1.144 | Columnfa8e1et100LoopCh2Local | read-only | current | 8E1-ET100(T/S) Series card E1 channel 2 Loop Check State: 0:No 1:Yes |
| 1.3.6.1.4.1.4756.20.350.20.1.145 | Columnfa8e1et100LoopCh3Local | read-only | current | 8E1-ET100(T/S) Series card E1 channel 3 Loop Check State: 0:No 1:Yes |
| 1.3.6.1.4.1.4756.20.350.20.1.146 | Columnfa8e1et100LoopCh4Local | read-only | current | 8E1-ET100(T/S) Series card E1 channel 4 Loop Check State: 0:No 1:Yes |
| 1.3.6.1.4.1.4756.20.350.20.1.147 | Columnfa8e1et100LoopCh5Local | read-only | current | 8E1-ET100(T/S) Series card E1 channel 5 Loop Check State: 0:No 1:Yes |
| 1.3.6.1.4.1.4756.20.350.20.1.148 | Columnfa8e1et100LoopCh6Local | read-only | current | 8E1-ET100(T/S) Series card E1 channel 6 Loop Check State: 0:No 1:Yes |
| 1.3.6.1.4.1.4756.20.350.20.1.149 | Columnfa8e1et100LoopCh7Local | read-only | current | 8E1-ET100(T/S) Series card E1 channel 7 Loop Check State: 0:No 1:Yes |
| 1.3.6.1.4.1.4756.20.350.20.1.150 | Columnfa8e1et100LoopCh8Local | read-only | current | 8E1-ET100(T/S) Series card E1 channel 8 Loop Check State: 0:No 1:Yes |
| 1.3.6.1.4.1.4756.20.350.20.1.151 | Columnfa8e1et100DefectCh1Local | read-only | current | 8E1-ET100(T/S) Series card E1 channel 1 Defect Status: 0:No 1:Yes |
| 1.3.6.1.4.1.4756.20.350.20.1.152 | Columnfa8e1et100DefectCh2Local | read-only | current | 8E1-ET100(T/S) Series card E1 channel 2 Defect Status: 0:No 1:Yes |
| 1.3.6.1.4.1.4756.20.350.20.1.153 | Columnfa8e1et100DefectCh3Local | read-only | current | 8E1-ET100(T/S) Series card E1 channel 3 Defect Status: 0:No 1:Yes |
| 1.3.6.1.4.1.4756.20.350.20.1.154 | Columnfa8e1et100DefectCh4Local | read-only | current | 8E1-ET100(T/S) Series card E1 channel 4 Defect Status: 0:No 1:Yes |
| 1.3.6.1.4.1.4756.20.350.20.1.155 | Columnfa8e1et100DefectCh5Local | read-only | current | 8E1-ET100(T/S) Series card E1 channel 5 Defect Status: 0:No 1:Yes |
| 1.3.6.1.4.1.4756.20.350.20.1.156 | Columnfa8e1et100DefectCh6Local | read-only | current | 8E1-ET100(T/S) Series card E1 channel 6 Defect Status: 0:No 1:Yes |
| 1.3.6.1.4.1.4756.20.350.20.1.157 | Columnfa8e1et100DefectCh7Local | read-only | current | 8E1-ET100(T/S) Series card E1 channel 7 Defect Status: 0:No 1:Yes |
| 1.3.6.1.4.1.4756.20.350.20.1.158 | Columnfa8e1et100DefectCh8Local | read-only | current | 8E1-ET100(T/S) Series card E1 channel 8 Defect Status: 0:No 1:Yes |
| 1.3.6.1.4.1.4756.20.350.20.1.159 | Columnfa8e1et100FxSignalLocal | read-only | current | 8E1-ET100(T/S) Series card Fiber signal detect(SD): 0:Fiber unplugged 1:Signal detected |
| 1.3.6.1.4.1.4756.20.350.20.1.160 | Columnfa8e1et100PortResetLocal | read-write | current | 8E1-ET100(T/S) Series card Port Reset: 0:Action 1:Off |
| 1.3.6.1.4.1.4756.20.350.20.1.161 | Columnfa8e1et100VLANModeLocal | read-write | current | 8E1-ET100(T/S) Series card VLAN mode: 0:MODE2 1:MODE1 |
| 1.3.6.1.4.1.4756.20.350.20.1.162 | Columnfa8e1et100ETagSelectEntryLocal | read-write | current | 8E1-ET100(T/S) Series card ETag select entry: |
| 1.3.6.1.4.1.4756.20.350.20.1.163 | Columnfa8e1et100ETagMethodLocal | read-write | current | 8E1-ET100(T/S) Series card ETag Method: 0: Intouch 1: Add Tag 2: Remove Tag |
| 1.3.6.1.4.1.4756.20.350.20.1.164 | Columnfa8e1et100VLANTableVID1Local | read-write | current | 8E1-ET100(T/S) Series card VLAN Table: VLAN ID1 |
| 1.3.6.1.4.1.4756.20.350.20.1.165 | Columnfa8e1et100VLANTableVID2Local | read-write | current | 8E1-ET100(T/S) Series card VLAN Table: VLAN ID2 |
| 1.3.6.1.4.1.4756.20.350.20.1.166 | Columnfa8e1et100VLANTableVID3Local | read-write | current | 8E1-ET100(T/S) Series card VLAN Table: VLAN ID3 |
| 1.3.6.1.4.1.4756.20.350.20.1.167 | Columnfa8e1et100VLANTableVID4Local | read-write | current | 8E1-ET100(T/S) Series card VLAN Table: VLAN ID4 |
| 1.3.6.1.4.1.4756.20.350.20.1.168 | Columnfa8e1et100VLANTableVID5Local | read-write | current | 8E1-ET100(T/S) Series card VLAN Table: VLAN ID5 |
| 1.3.6.1.4.1.4756.20.350.20.1.169 | Columnfa8e1et100VLANTableVID6Local | read-write | current | 8E1-ET100(T/S) Series card VLAN Table: VLAN ID6 |
| 1.3.6.1.4.1.4756.20.350.20.1.170 | Columnfa8e1et100VLANTableVID7Local | read-write | current | 8E1-ET100(T/S) Series card VLAN Table: VLAN ID7 |
| 1.3.6.1.4.1.4756.20.350.20.1.171 | Columnfa8e1et100VLANTableVID8Local | read-write | current | 8E1-ET100(T/S) Series card VLAN Table: VLAN ID8 |
| 1.3.6.1.4.1.4756.20.350.20.1.172 | Columnfa8e1et100VLANTableVID9Local | read-write | current | 8E1-ET100(T/S) Series card VLAN Table: VLAN ID9 |
| 1.3.6.1.4.1.4756.20.350.20.1.173 | Columnfa8e1et100VLANTableVID10Local | read-write | current | 8E1-ET100(T/S) Series card VLAN Table: VLAN ID10 |
| 1.3.6.1.4.1.4756.20.350.20.1.174 | Columnfa8e1et100VLANTableVID11Local | read-write | current | 8E1-ET100(T/S) Series card VLAN Table: VLAN ID11 |
| 1.3.6.1.4.1.4756.20.350.20.1.175 | Columnfa8e1et100VLANTableVID12Local | read-write | current | 8E1-ET100(T/S) Series card VLAN Table: VLAN ID12 |
| 1.3.6.1.4.1.4756.20.350.20.1.176 | Columnfa8e1et100VLANTableVID13Local | read-write | current | 8E1-ET100(T/S) Series card VLAN Table: VLAN ID13 |
| 1.3.6.1.4.1.4756.20.350.20.1.177 | Columnfa8e1et100VLANTableVID14Local | read-write | current | 8E1-ET100(T/S) Series card VLAN Table: VLAN ID14 |
| 1.3.6.1.4.1.4756.20.350.20.1.178 | Columnfa8e1et100VLANTableVID15Local | read-write | current | 8E1-ET100(T/S) Series card VLAN Table: VLAN ID15 |
| 1.3.6.1.4.1.4756.20.350.20.1.179 | Columnfa8e1et100VLANTableVID16Local | read-write | current | 8E1-ET100(T/S) Series card VLAN Table: VLAN ID16 |
| 1.3.6.1.4.1.4756.20.351 | Nodef8E1RemoteCards | |||
| 1.3.6.1.4.1.4756.20.351.20 | Tablef8E1RemoteTable | not-accessible | current | A list of local FRM220-8E1-ET100 series card entries. The number of entries is f8E1-No-L. |
| 1.3.6.1.4.1.4756.20.351.20.1 | Rowf8E1RemoteEntry | not-accessible | current | An entry containing management information applicable to a particular local FRM220-8E1 series card. |
| 1.3.6.1.4.1.4756.20.351.20.1.1 | Columnfa8e1et100ChassisIndexRemote | read-only | current | A unique value for each card. It starts from 0 to 9 contiguously. |
| 1.3.6.1.4.1.4756.20.351.20.1.2 | Columnfa8e1et100SlotIndexRemote | read-only | current | A unique value for each card. It starts from 1 to 20 contiguously. |
| 1.3.6.1.4.1.4756.20.351.20.1.3 | Columnfa8e1et100CardHWVerRemote | read-only | current | 8E1-ET100(T/S) Series card hardware version x.xxx |
| 1.3.6.1.4.1.4756.20.351.20.1.4 | Columnfa8e1et100CardFWVerRemote | read-only | current | 8E1-ET100(T/S) Series card firmware version x.xxx |
| 1.3.6.1.4.1.4756.20.351.20.1.5 | Columnfa8e1et100CardCPLDVerRemote | read-only | current | 8E1-ET100(T/S) Series card CPLD version x.xxx |
| 1.3.6.1.4.1.4756.20.351.20.1.6 | Columnfa8e1et100CardFPGAVerRemote | read-only | current | 8E1-ET100(T/S) Series card FPGA version x.xxx |
| 1.3.6.1.4.1.4756.20.351.20.1.7 | Columnfa8e1et100ModelRemote | read-only | current | Card Type: 0:8E1-ET100T 1:8E1-ET100S |
| 1.3.6.1.4.1.4756.20.351.20.1.8 | Columnfa8e1et100SystemStatusRemote | read-only | current | 8E1-ET100(T/S) Series card system status: 0:Normal 1:Alarm |
| 1.3.6.1.4.1.4756.20.351.20.1.9 | Columnfa8e1et100DeviceActiveRemote | read-only | current | 8E1-ET100(T/S) Series card active: 0:Disable 1:Enable |
| 1.3.6.1.4.1.4756.20.351.20.1.10 | Columnfa8e1et100SetToDefaultRemote | read-write | current | 8E1-ET100(T/S) Series card port set to default: 0:Off 1:Trigger |
| 1.3.6.1.4.1.4756.20.351.20.1.11 | Columnfa8e1et100E1Ch1SingalRemote | read-only | current | 8E1-ET100(T/S) Series card E1 channel 1 signal status: 0:Singal Loss 1:Normal |
| 1.3.6.1.4.1.4756.20.351.20.1.12 | Columnfa8e1et100E1Ch2SingalRemote | read-only | current | 8E1-ET100(T/S) Series card E1 channel 2 signal status: 0:Singal Loss 1:Normal |
| 1.3.6.1.4.1.4756.20.351.20.1.13 | Columnfa8e1et100E1Ch3SingalRemote | read-only | current | 8E1-ET100(T/S) Series card E1 channel 3 signal status: 0:Singal Loss 1:Normal |
| 1.3.6.1.4.1.4756.20.351.20.1.14 | Columnfa8e1et100E1Ch4SingalRemote | read-only | current | 8E1-ET100(T/S) Series card E1 channel 4 signal status: 0:Singal Loss 1:Normal |
| 1.3.6.1.4.1.4756.20.351.20.1.15 | Columnfa8e1et100E1Ch5SingalRemote | read-only | current | 8E1-ET100(T/S) Series card E1 channel 5 signal status: 0:Singal Loss 1:Normal |
| 1.3.6.1.4.1.4756.20.351.20.1.16 | Columnfa8e1et100E1Ch6SingalRemote | read-only | current | 8E1-ET100(T/S) Series card E1 channel 6 signal status: 0:Singal Loss 1:Normal |
| 1.3.6.1.4.1.4756.20.351.20.1.17 | Columnfa8e1et100E1Ch7SingalRemote | read-only | current | 8E1-ET100(T/S) Series card E1 channel 7 signal status: 0:Singal Loss 1:Normal |
| 1.3.6.1.4.1.4756.20.351.20.1.18 | Columnfa8e1et100E1Ch8SingalRemote | read-only | current | 8E1-ET100(T/S) Series card E1 channel 8 signal status: 0:Singal Loss 1:Normal |
| 1.3.6.1.4.1.4756.20.351.20.1.19 | Columnfa8e1et100E1Ch1SyncRemote | read-only | current | 8E1-ET100(T/S) Series card E1 channel 1 sync status: 0:Sync Loss 1:Sync |
| 1.3.6.1.4.1.4756.20.351.20.1.20 | Columnfa8e1et100E1Ch2SyncRemote | read-only | current | 8E1-ET100(T/S) Series card E1 channel 2 sync status: 0:Sync Loss 1:Sync |
| 1.3.6.1.4.1.4756.20.351.20.1.21 | Columnfa8e1et100E1Ch3SyncRemote | read-only | current | 8E1-ET100(T/S) Series card E1 channel 3 sync status: 0:Sync Loss 1:Sync |
| 1.3.6.1.4.1.4756.20.351.20.1.22 | Columnfa8e1et100E1Ch4SyncRemote | read-only | current | 8E1-ET100(T/S) Series card E1 channel 4 sync status: 0:Sync Loss 1:Sync |
| 1.3.6.1.4.1.4756.20.351.20.1.23 | Columnfa8e1et100E1Ch5SyncRemote | read-only | current | 8E1-ET100(T/S) Series card E1 channel 5 sync status: 0:Sync Loss 1:Sync |
| 1.3.6.1.4.1.4756.20.351.20.1.24 | Columnfa8e1et100E1Ch6SyncRemote | read-only | current | 8E1-ET100(T/S) Series card E1 channel 6 sync status: 0:Sync Loss 1:Sync |
| 1.3.6.1.4.1.4756.20.351.20.1.25 | Columnfa8e1et100E1Ch7SyncRemote | read-only | current | 8E1-ET100(T/S) Series card E1 channel 7 sync status: 0:Sync Loss 1:Sync |
| 1.3.6.1.4.1.4756.20.351.20.1.26 | Columnfa8e1et100E1Ch8SyncRemote | read-only | current | 8E1-ET100(T/S) Series card E1 channel 8 sync status: 0:Sync Loss 1:Sync |
| 1.3.6.1.4.1.4756.20.351.20.1.27 | Columnfa8e1et100E1Ch1RecvAISRemote | read-only | current | 8E1-ET100(T/S) Series card E1 channel 1 receive AIS status: 0:No 1:Yes |
| 1.3.6.1.4.1.4756.20.351.20.1.28 | Columnfa8e1et100E1Ch2RecvAISRemote | read-only | current | 8E1-ET100(T/S) Series card E1 channel 2 receive AIS status: 0:No 1:Yes |
| 1.3.6.1.4.1.4756.20.351.20.1.29 | Columnfa8e1et100E1Ch3RecvAISRemote | read-only | current | 8E1-ET100(T/S) Series card E1 channel 3 receive AIS status: 0:No 1:Yes |
| 1.3.6.1.4.1.4756.20.351.20.1.30 | Columnfa8e1et100E1Ch4RecvAISRemote | read-only | current | 8E1-ET100(T/S) Series card E1 channel 4 receive AIS status: 0:No 1:Yes |
| 1.3.6.1.4.1.4756.20.351.20.1.31 | Columnfa8e1et100E1Ch5RecvAISRemote | read-only | current | 8E1-ET100(T/S) Series card E1 channel 5 receive AIS status: 0:No 1:Yes |
| 1.3.6.1.4.1.4756.20.351.20.1.32 | Columnfa8e1et100E1Ch6RecvAISRemote | read-only | current | 8E1-ET100(T/S) Series card E1 channel 6 receive AIS status: 0:No 1:Yes |
| 1.3.6.1.4.1.4756.20.351.20.1.33 | Columnfa8e1et100E1Ch7RecvAISRemote | read-only | current | 8E1-ET100(T/S) Series card E1 channel 7 receive AIS status: 0:No 1:Yes |
| 1.3.6.1.4.1.4756.20.351.20.1.34 | Columnfa8e1et100E1Ch8RecvAISRemote | read-only | current | 8E1-ET100(T/S) Series card E1 channel 8 receive AIS status: 0:No 1:Yes |
| 1.3.6.1.4.1.4756.20.351.20.1.35 | Columnfa8e1et100E1Ch1ConnTypeRemote | read-only | current | 8E1-ET100(T/S) Series card E1 channel 1 connector type: 0:RJ-48C 1:BNC |
| 1.3.6.1.4.1.4756.20.351.20.1.36 | Columnfa8e1et100E1Ch2ConnTypeRemote | read-only | current | 8E1-ET100(T/S) Series card E1 channel 2 connector type: 0:RJ-48C 1:BNC |
| 1.3.6.1.4.1.4756.20.351.20.1.37 | Columnfa8e1et100E1Ch3ConnTypeRemote | read-only | current | 8E1-ET100(T/S) Series card E1 channel 3 connector type: 0:RJ-48C 1:BNC |
| 1.3.6.1.4.1.4756.20.351.20.1.38 | Columnfa8e1et100E1Ch4ConnTypeRemote | read-only | current | 8E1-ET100(T/S) Series card E1 channel 4 connector type: 0:RJ-48C 1:BNC |
| 1.3.6.1.4.1.4756.20.351.20.1.39 | Columnfa8e1et100E1Ch5ConnTypeRemote | read-only | current | 8E1-ET100(T/S) Series card E1 channel 5 connector type: 0:RJ-48C 1:BNC |
| 1.3.6.1.4.1.4756.20.351.20.1.40 | Columnfa8e1et100E1Ch6ConnTypeRemote | read-only | current | 8E1-ET100(T/S) Series card E1 channel 6 connector type: 0:RJ-48C 1:BNC |
| 1.3.6.1.4.1.4756.20.351.20.1.41 | Columnfa8e1et100E1Ch7ConnTypeRemote | read-only | current | 8E1-ET100(T/S) Series card E1 channel 7 connector type: 0:RJ-48C 1:BNC |
| 1.3.6.1.4.1.4756.20.351.20.1.42 | Columnfa8e1et100E1Ch8ConnTypeRemote | read-only | current | 8E1-ET100(T/S) Series card E1 channel 8 connector type: 0:RJ-48C 1:BNC |
| 1.3.6.1.4.1.4756.20.351.20.1.43 | Columnfa8e1et100E1Ch1RAIRemote | read-only | current | 8E1-ET100(T/S) Series card E1 channel 1 RAI status: 0:No 1:Yes |
| 1.3.6.1.4.1.4756.20.351.20.1.44 | Columnfa8e1et100E1Ch2RAIRemote | read-only | current | 8E1-ET100(T/S) Series card E1 channel 2 RAI status: 0:No 1:Yes |
| 1.3.6.1.4.1.4756.20.351.20.1.45 | Columnfa8e1et100E1Ch3RAIRemote | read-only | current | 8E1-ET100(T/S) Series card E1 channel 3 RAI status: 0:No 1:Yes |
| 1.3.6.1.4.1.4756.20.351.20.1.46 | Columnfa8e1et100E1Ch4RAIRemote | read-only | current | 8E1-ET100(T/S) Series card E1 channel 4 RAI status: 0:No 1:Yes |
| 1.3.6.1.4.1.4756.20.351.20.1.47 | Columnfa8e1et100E1Ch5RAIRemote | read-only | current | 8E1-ET100(T/S) Series card E1 channel 5 RAI status: 0:No 1:Yes |
| 1.3.6.1.4.1.4756.20.351.20.1.48 | Columnfa8e1et100E1Ch6RAIRemote | read-only | current | 8E1-ET100(T/S) Series card E1 channel 6 RAI status: 0:No 1:Yes |
| 1.3.6.1.4.1.4756.20.351.20.1.49 | Columnfa8e1et100E1Ch7RAIRemote | read-only | current | 8E1-ET100(T/S) Series card E1 channel 7 RAI status: 0:No 1:Yes |
| 1.3.6.1.4.1.4756.20.351.20.1.50 | Columnfa8e1et100E1Ch8RAIRemote | read-only | current | 8E1-ET100(T/S) Series card E1 channel 8 RAI status: 0:No 1:Yes |
| 1.3.6.1.4.1.4756.20.351.20.1.51 | Columnfa8e1et100E1Ch1LOMFRemote | read-only | current | 8E1-ET100(T/S) Series card E1 channel 1 LOMF status: 0:No 1:Yes |
| 1.3.6.1.4.1.4756.20.351.20.1.52 | Columnfa8e1et100E1Ch2LOMFRemote | read-only | current | 8E1-ET100(T/S) Series card E1 channel 2 LOMF status: 0:No 1:Yes |
| 1.3.6.1.4.1.4756.20.351.20.1.53 | Columnfa8e1et100E1Ch3LOMFRemote | read-only | current | 8E1-ET100(T/S) Series card E1 channel 3 LOMF status: 0:No 1:Yes |
| 1.3.6.1.4.1.4756.20.351.20.1.54 | Columnfa8e1et100E1Ch4LOMFRemote | read-only | current | 8E1-ET100(T/S) Series card E1 channel 4 LOMF status: 0:No 1:Yes |
| 1.3.6.1.4.1.4756.20.351.20.1.55 | Columnfa8e1et100E1Ch5LOMFRemote | read-only | current | 8E1-ET100(T/S) Series card E1 channel 5 LOMF status: 0:No 1:Yes |
| 1.3.6.1.4.1.4756.20.351.20.1.56 | Columnfa8e1et100E1Ch6LOMFRemote | read-only | current | 8E1-ET100(T/S) Series card E1 channel 6 LOMF status: 0:No 1:Yes |
| 1.3.6.1.4.1.4756.20.351.20.1.57 | Columnfa8e1et100E1Ch7LOMFRemote | read-only | current | 8E1-ET100(T/S) Series card E1 channel 7 LOMF status: 0:No 1:Yes |
| 1.3.6.1.4.1.4756.20.351.20.1.58 | Columnfa8e1et100E1Ch8LOMFRemote | read-only | current | 8E1-ET100(T/S) Series card E1 channel 8 LOMF status: 0:No 1:Yes |
| 1.3.6.1.4.1.4756.20.351.20.1.59 | Columnfa8e1et100E1Ch1ActiveRemote | read-only | current | 8E1-ET100(T/S) Series card E1 channel 1 active status: 0:Inactive 1:Active |
| 1.3.6.1.4.1.4756.20.351.20.1.60 | Columnfa8e1et100E1Ch2ActiveRemote | read-only | current | 8E1-ET100(T/S) Series card E1 channel 2 active status: 0:Inactive 1:Active |
| 1.3.6.1.4.1.4756.20.351.20.1.61 | Columnfa8e1et100E1Ch3ActiveRemote | read-only | current | 8E1-ET100(T/S) Series card E1 channel 3 active status: 0:Inactive 1:Active |
| 1.3.6.1.4.1.4756.20.351.20.1.62 | Columnfa8e1et100E1Ch4ActiveRemote | read-only | current | 8E1-ET100(T/S) Series card E1 channel 4 active status: 0:Inactive 1:Active |
| 1.3.6.1.4.1.4756.20.351.20.1.63 | Columnfa8e1et100E1Ch5ActiveRemote | read-only | current | 8E1-ET100(T/S) Series card E1 channel 5 active status: 0:Inactive 1:Active |
| 1.3.6.1.4.1.4756.20.351.20.1.64 | Columnfa8e1et100E1Ch6ActiveRemote | read-only | current | 8E1-ET100(T/S) Series card E1 channel 6 active status: 0:Inactive 1:Active |
| 1.3.6.1.4.1.4756.20.351.20.1.65 | Columnfa8e1et100E1Ch7ActiveRemote | read-only | current | 8E1-ET100(T/S) Series card E1 channel 7 active status: 0:Inactive 1:Active |
| 1.3.6.1.4.1.4756.20.351.20.1.66 | Columnfa8e1et100E1Ch8ActiveRemote | read-only | current | 8E1-ET100(T/S) Series card E1 channel 8 active status: 0:Inactive 1:Active |
| 1.3.6.1.4.1.4756.20.351.20.1.67 | Columnfa8e1et100E1Ch1LoopBackRemote | read-write | current | 8E1-ET100(T/S) Series card port E1 channel 1 loop back: 0:Off 2:RLB (Max used 4 channels) |
| 1.3.6.1.4.1.4756.20.351.20.1.68 | Columnfa8e1et100E1Ch2LoopBackRemote | read-write | current | 8E1-ET100(T/S) Series card port E1 channel 2 loop back: 0:Off 2:RLB (Max used 4 channels) |
| 1.3.6.1.4.1.4756.20.351.20.1.69 | Columnfa8e1et100E1Ch3LoopBackRemote | read-write | current | 8E1-ET100(T/S) Series card port E1 channel 3 loop back: 0:Off 2:RLB (Max used 4 channels) |
| 1.3.6.1.4.1.4756.20.351.20.1.70 | Columnfa8e1et100E1Ch4LoopBackRemote | read-write | current | 8E1-ET100(T/S) Series card port E1 channel 4 loop back: 0:Off 2:RLB (Max used 4 channels) |
| 1.3.6.1.4.1.4756.20.351.20.1.71 | Columnfa8e1et100E1Ch5LoopBackRemote | read-write | current | 8E1-ET100(T/S) Series card port E1 channel 5 loop back: 0:Off 2:RLB (Max used 4 channels) |
| 1.3.6.1.4.1.4756.20.351.20.1.72 | Columnfa8e1et100E1Ch6LoopBackRemote | read-write | current | 8E1-ET100(T/S) Series card port E1 channel 6 loop back: 0:Off 2:RLB (Max used 4 channels) |
| 1.3.6.1.4.1.4756.20.351.20.1.73 | Columnfa8e1et100E1Ch7LoopBackRemote | read-write | current | 8E1-ET100(T/S) Series card port E1 channel 7 loop back: 0:Off 2:RLB (Max used 4 channels) |
| 1.3.6.1.4.1.4756.20.351.20.1.74 | Columnfa8e1et100E1Ch8LoopBackRemote | read-write | current | 8E1-ET100(T/S) Series card port E1 channel 8 loop back: 0:Off 2:RLB (Max used 4 channels) |
| 1.3.6.1.4.1.4756.20.351.20.1.75 | Columnfa8e1et100FxLinkRemote | read-only | current | 8E1-ET100S Series card Fiber siganl detect status: 0:Down or Fiber unplugged 1:Up or Singal detected |
| 1.3.6.1.4.1.4756.20.351.20.1.76 | Columnfa8e1et100FxLaserRemote | read-only | current | 8E1-ET100S Series card laser status: 0:Normal 1:Error |
| 1.3.6.1.4.1.4756.20.351.20.1.77 | Columnfa8e1et100FxActiveRemote | read-write | current | 8E1-ET100S Series card Fiber active: 0:Inactive 1:Active |
| 1.3.6.1.4.1.4756.20.351.20.1.78 | Columnfa8e1et100FxLaserOutputRemote | read-write | current | 8E1-ET100S Series card laser output: 0:disable 1:Enable |
| 1.3.6.1.4.1.4756.20.351.20.1.79 | Columnfa8e1et100FxOpModeRemote | read-write | current | 8E1-ET100S Series card operation mode: 0:Switch 1:Convert |
| 1.3.6.1.4.1.4756.20.351.20.1.80 | Columnfa8e1et100UtpLinkRemote | read-only | current | 8E1-ET100T Series card UTP link status: 0:Link Down 1:Link Up |
| 1.3.6.1.4.1.4756.20.351.20.1.81 | Columnfa8e1et100UtpStatusRemote | read-only | current | 8E1-ET100T Series card UTP link mode status: 0:None, Maybe link down 1:Link at 10Mbps, Half duplex 2:Link at 10Mbps, Full duplex 3:Link at 100Mbps, Half duplex… |
| 1.3.6.1.4.1.4756.20.351.20.1.82 | Columnfa8e1et100UtpFlowCtrlStsRemote | read-only | current | 8E1-ET100T Series card UTP flow control status: 0:Disable 1:Enable |
| 1.3.6.1.4.1.4756.20.351.20.1.83 | Columnfa8e1et100UtpModeRemote | read-write | current | 8E1-ET100T Series card UTP mode: 0:Disable 1:Enable and autoNegotiation 3:Enable and force to 10Mbps, Half duplex 4:Enable and force to 10Mbps, Full duplex 5:E… |
| 1.3.6.1.4.1.4756.20.351.20.1.84 | Columnfa8e1et100UtpFlowCtrlRemote | read-write | current | 8E1-ET100T Series card UTP flow control: 0:Disable 1:Enable |
| 1.3.6.1.4.1.4756.20.351.20.1.85 | Columnfa8e1et100SpeedLimitRemote | read-write | current | 8E1-ET100(T/S) Series card speed limit: Limited = this value * 32Kbps, this value is restricted to 0 ~ 3125, 0 to disable |
| 1.3.6.1.4.1.4756.20.351.20.1.86 | Columnfa8e1et100VlanAwareRemote | read-write | current | 8E1-ET100(T/S) Series card 802.1q VLAN tag aware: 0:Disable 1:Enable |
| 1.3.6.1.4.1.4756.20.351.20.1.87 | Columnfa8e1et100VlanIDRemote | read-write | current | 8E1-ET100(T/S) Series card VLAN ID: The ID is restricted to 1 ~ 4094 |
| 1.3.6.1.4.1.4756.20.351.20.1.88 | Columnfa8e1et100RemoteDeviceRemote | read-only | current | FRM220A-8E1 Series card remote device status: 0:Link Down 1:Link Up |
| 1.3.6.1.4.1.4756.20.351.20.1.89 | Columnfa8e1et100RemotePowerRemote | read-only | current | 8E1-ET100(T/S) Series card remote device power status: 0:Normal 1:Power off |
| 1.3.6.1.4.1.4756.20.351.20.1.90 | Columnfa8e1et100TimingSourceRemote | read-write | current | 8E1-ET100(T/S) Series card clock: 0:Internal oscillatro 1:Recovery from E1 channel 1 2:Recovery from E1 channel 2 3:Recovery from E1 channel 3 4:Recovery from … |
| 1.3.6.1.4.1.4756.20.351.20.1.91 | Columnfa8e1et100FCSofGFPRemote | read-write | current | 8E1-ET100(T/S) Series card FCS of GFP: 0:Disable 1:Enable |
| 1.3.6.1.4.1.4756.20.351.20.1.92 | Columnfa8e1et100AutoChAdjustRemote | read-write | current | 8E1-ET100(T/S) Series card auto channel Bdjust: 0:Disable 1:Enable |
| 1.3.6.1.4.1.4756.20.351.20.1.93 | Columnfa8e1et100PayloadScrambleRemote | read-write | current | 8E1-ET100(T/S) Series card payload scramble: 0:Disable 1:Enable |
| 1.3.6.1.4.1.4756.20.351.20.1.94 | Columnfa8e1et100FailoverRemote | read-write | current | 8E1-ET100(T/S) Series card failover: 0:Disable 1:Enable |
| 1.3.6.1.4.1.4756.20.351.20.1.95 | Columnfa8e1et100LOMRemote | read-only | current | 8E1-ET100(T/S) Series card LOM status: 0:No 1:Yes |
| 1.3.6.1.4.1.4756.20.351.20.1.96 | Columnfa8e1et100SQMRemote | read-only | current | 8E1-ET100(T/S) Series card SQM status: 0:No 1:Yes |
| 1.3.6.1.4.1.4756.20.351.20.1.97 | Columnfa8e1et100CRCRemote | read-only | current | 8E1-ET100(T/S) Series card CRC status: 0:No 1:Yes |
| 1.3.6.1.4.1.4756.20.351.20.1.98 | Columnfa8e1et100LOARemote | read-only | current | 8E1-ET100(T/S) Series card LOA status: 0:No 1:Yes |
| 1.3.6.1.4.1.4756.20.351.20.1.99 | Columnfa8e1et100LFDRemote | read-only | current | 8E1-ET100(T/S) Series card LFD status: 0:No 1:Yes |
| 1.3.6.1.4.1.4756.20.351.20.1.100 | Columnfa8e1et100DDTORemote | read-only | current | 8E1-ET100(T/S) Series card DDTO status: 0:No 1:Yes |
| 1.3.6.1.4.1.4756.20.351.20.1.101 | Columnfa8e1et100VcatMember1Remote | read-write | current | 8E1-ET100(T/S) Series card VACT member 0: 0:Disable 1:Enable |
| 1.3.6.1.4.1.4756.20.351.20.1.102 | Columnfa8e1et100VcatMember2Remote | read-write | current | 8E1-ET100(T/S) Series card VACT member 1: 0:Disable 1:Enable |
| 1.3.6.1.4.1.4756.20.351.20.1.103 | Columnfa8e1et100VcatMember3Remote | read-write | current | 8E1-ET100(T/S) Series card VACT member 3: 0:Disable 1:Enable |
| 1.3.6.1.4.1.4756.20.351.20.1.104 | Columnfa8e1et100VcatMember4Remote | read-write | current | 8E1-ET100(T/S) Series card VACT member 4: 0:Disable 1:Enable |
| 1.3.6.1.4.1.4756.20.351.20.1.105 | Columnfa8e1et100VcatMember5Remote | read-write | current | 8E1-ET100(T/S) Series card VACT member 5: 0:Disable 1:Enable |
| 1.3.6.1.4.1.4756.20.351.20.1.106 | Columnfa8e1et100VcatMember6Remote | read-write | current | 8E1-ET100(T/S) Series card VACT member 6: 0:Disable 1:Enable |
| 1.3.6.1.4.1.4756.20.351.20.1.107 | Columnfa8e1et100VcatMember7Remote | read-write | current | 8E1-ET100(T/S) Series card VACT member 7: 0:Disable 1:Enable |
| 1.3.6.1.4.1.4756.20.351.20.1.108 | Columnfa8e1et100VcatMember8Remote | read-write | current | 8E1-ET100(T/S) Series card VACT member 8: 0:Disable 1:Enable |
| 1.3.6.1.4.1.4756.20.351.20.1.109 | Columnfa8e1et100SnmpChannel1Remote | read-write | current | 8E1-ET100(T/S) Series card SNMP channel 0: 0:No use 1:Use |
| 1.3.6.1.4.1.4756.20.351.20.1.110 | Columnfa8e1et100SnmpChannel2Remote | read-write | current | 8E1-ET100(T/S) Series card SNMP channel 1: 0:No use 1:Use |
| 1.3.6.1.4.1.4756.20.351.20.1.111 | Columnfa8e1et100SnmpChannel3Remote | read-write | current | 8E1-ET100(T/S) Series card SNMP channel 3: 0:No use 1:Use |
| 1.3.6.1.4.1.4756.20.351.20.1.112 | Columnfa8e1et100SnmpChannel4Remote | read-write | current | 8E1-ET100(T/S) Series card SNMP channel 4: 0:No use 1:Use |
| 1.3.6.1.4.1.4756.20.351.20.1.113 | Columnfa8e1et100ErrSecRemote | read-only | current | 8E1-ET100(T/S) Series card, errored seconds of BERT result. |
| 1.3.6.1.4.1.4756.20.351.20.1.114 | Columnfa8e1et100ErrFreeSecRemote | read-only | current | 8E1-ET100(T/S) Series card, errored free seconds of BERT result. |
| 1.3.6.1.4.1.4756.20.351.20.1.115 | Columnfa8e1et100ServErrSecRemote | read-only | current | 8E1-ET100(T/S) Series card, severely errored seconds of BERT result. |
| 1.3.6.1.4.1.4756.20.351.20.1.116 | Columnfa8e1et100BertFunctionRemote | read-write | current | 8E1-ET100(T/S) Series card bert function: 0:Disable 1:Enable |
| 1.3.6.1.4.1.4756.20.351.20.1.117 | Columnfa8e1et100ClrBertDataRemote | read-write | current | 8E1-ET100(T/S) Series card bert data clear: 0:Normal 1:Clear |
| 1.3.6.1.4.1.4756.20.351.20.1.118 | Columnfa8e1et100BertE1ChannelRemote | read-write | current | 8E1-ET100(T/S) Series card bert E1 channel number: 0:E1 channel 1 1:E1 channel 2 2:E1 channel 3 3:E1 channel 4 4:E1 channel 5 5:E1 channel 6 6:E1 channel 7 7:E… |
| 1.3.6.1.4.1.4756.20.351.20.1.119 | Columnfa8e1et100RmonFunctionRemote | read-write | current | 8E1-ET100(T/S) Series RMON function : 0:Disable 1:Enable |
| 1.3.6.1.4.1.4756.20.351.20.1.120 | Columnfa8e1et100RmonTxRemote | read-only | current | 8E1-ET100(T/S) Series card RMON Tx counter. |
| 1.3.6.1.4.1.4756.20.351.20.1.121 | Columnfa8e1et100RmonRxRemote | read-only | current | 8E1-ET100(T/S) Series card RMON Rx counter. |
| 1.3.6.1.4.1.4756.20.351.20.1.122 | Columnfa8e1et100ClrRmonTxRemote | read-write | current | 8E1-ET100(T/S) Series card clear RMON Tx counter: 0:Normal 1:Clear |
| 1.3.6.1.4.1.4756.20.351.20.1.123 | Columnfa8e1et100ClrRmonRxRemote | read-write | current | 8E1-ET100(T/S) Series card clear RMON Rx counter: 0:Normal 1:Clear |
| 1.3.6.1.4.1.4756.20.351.20.1.124 | Columnfa8e1et100SfpRemote | read-only | current | 8E1-ET100(T/S) Series card, SFP existed: 0:No 1:Yes |
| 1.3.6.1.4.1.4756.20.351.20.1.125 | Columnfa8e1et100SfpVendorRemote | read-only | current | 8E1-ET100(T/S) Series card, Vendor name of SFP. |
| 1.3.6.1.4.1.4756.20.351.20.1.126 | Columnfa8e1et100SfpPartNoRemote | read-only | current | 8E1-ET100(T/S) Series card, Vendor part number of SFP. |
| 1.3.6.1.4.1.4756.20.351.20.1.127 | Columnfa8e1et100SfpFiberTypeRemote | read-only | current | 8E1-ET100(T/S) Series card, Fiber Type of SFP. |
| 1.3.6.1.4.1.4756.20.351.20.1.128 | Columnfa8e1et100SfpTxWaveLenRemote | read-only | current | 8E1-ET100(T/S) Series card, Tx Wave length of SFP. |
| 1.3.6.1.4.1.4756.20.351.20.1.129 | Columnfa8e1et100SfpRxWaveLenRemote | read-only | current | 8E1-ET100(T/S) Series card, Rx Wave length of SFP. |
| 1.3.6.1.4.1.4756.20.351.20.1.130 | Columnfa8e1et100SfpLinkLenRemote | read-only | current | 8E1-ET100(T/S) Series card, Link length of SFP. |
| 1.3.6.1.4.1.4756.20.351.20.1.131 | Columnfa8e1et100SfpModelIDRemote | read-only | current | 8E1-ET100(T/S) Series card, model ID of SFP. |
| 1.3.6.1.4.1.4756.20.351.20.1.132 | Columnfa8e1et100SfpVersionRemote | read-only | current | 8E1-ET100(T/S) Series card, the version of SFP. |
| 1.3.6.1.4.1.4756.20.351.20.1.133 | Columnfa8e1et100SfpModelTypeRemote | read-only | current | 8E1-ET100(T/S) Series card, model type of SFP. |
| 1.3.6.1.4.1.4756.20.351.20.1.134 | Columnfa8e1et100DDInformationRemote | read-only | current | 8E1-ET100(T/S) Series card, D/D information of SFP Supported: 0:No, 1:Yes |
| 1.3.6.1.4.1.4756.20.351.20.1.135 | Columnfa8e1et100DDRxSensRemote | read-only | current | 8E1-ET100(T/S) Series card, Sensitivity of D/D information. |
| 1.3.6.1.4.1.4756.20.351.20.1.136 | Columnfa8e1et100DDTxPowerRemote | read-only | current | 8E1-ET100(T/S) Series card, Tx power of D/D information. |
| 1.3.6.1.4.1.4756.20.351.20.1.137 | Columnfa8e1et100DDRxPowerRemote | read-only | current | 8E1-ET100(T/S) Series card, Rx power of D/D information. |
| 1.3.6.1.4.1.4756.20.351.20.1.138 | Columnfa8e1et100DDTempRemote | read-only | current | 8E1-ET100(T/S) Series card, Temperature of D/D information in degree C. |
| 1.3.6.1.4.1.4756.20.351.20.1.139 | Columnfa8e1et100DDBiasRemote | read-only | current | 8E1-ET100(T/S) Series card, BIAS of D/D information. |
| 1.3.6.1.4.1.4756.20.351.20.1.140 | Columnfa8e1et100DDVoltageRemote | read-only | current | 8E1-ET100(T/S) Series card, Voltage of D/D information. |
| 1.3.6.1.4.1.4756.20.351.20.1.141 | Columnfa8e1et100ChannelDefectRemote | read-write | current | 8E1-ET100(T/S) Series card Channel Defect: 0:Disable 4:1E-4 6:1E-6 |
| 1.3.6.1.4.1.4756.20.351.20.1.142 | Columnfa8e1et100LoopDetectionRemote | read-write | current | 8E1-ET100(T/S) Series card Loop Detection: 0:Disable 1:Enable |
| 1.3.6.1.4.1.4756.20.351.20.1.143 | Columnfa8e1et100LoopCh1Remote | read-only | current | 8E1-ET100(T/S) Series card E1 channel 1 Loop Check State: 0:No 1:Yes |
| 1.3.6.1.4.1.4756.20.351.20.1.144 | Columnfa8e1et100LoopCh2Remote | read-only | current | 8E1-ET100(T/S) Series card E1 channel 2 Loop Check State: 0:No 1:Yes |
| 1.3.6.1.4.1.4756.20.351.20.1.145 | Columnfa8e1et100LoopCh3Remote | read-only | current | 8E1-ET100(T/S) Series card E1 channel 3 Loop Check State: 0:No 1:Yes |
| 1.3.6.1.4.1.4756.20.351.20.1.146 | Columnfa8e1et100LoopCh4Remote | read-only | current | 8E1-ET100(T/S) Series card E1 channel 4 Loop Check State: 0:No 1:Yes |
| 1.3.6.1.4.1.4756.20.351.20.1.147 | Columnfa8e1et100LoopCh5Remote | read-only | current | 8E1-ET100(T/S) Series card E1 channel 5 Loop Check State: 0:No 1:Yes |
| 1.3.6.1.4.1.4756.20.351.20.1.148 | Columnfa8e1et100LoopCh6Remote | read-only | current | 8E1-ET100(T/S) Series card E1 channel 6 Loop Check State: 0:No 1:Yes |
| 1.3.6.1.4.1.4756.20.351.20.1.149 | Columnfa8e1et100LoopCh7Remote | read-only | current | 8E1-ET100(T/S) Series card E1 channel 7 Loop Check State: 0:No 1:Yes |
| 1.3.6.1.4.1.4756.20.351.20.1.150 | Columnfa8e1et100LoopCh8Remote | read-only | current | 8E1-ET100(T/S) Series card E1 channel 8 Loop Check State: 0:No 1:Yes |
| 1.3.6.1.4.1.4756.20.351.20.1.151 | Columnfa8e1et100DefectCh1Remote | read-only | current | 8E1-ET100(T/S) Series card E1 channel 1 Defect Status: 0:No 1:Yes |
| 1.3.6.1.4.1.4756.20.351.20.1.152 | Columnfa8e1et100DefectCh2Remote | read-only | current | 8E1-ET100(T/S) Series card E1 channel 2 Defect Status: 0:No 1:Yes |
| 1.3.6.1.4.1.4756.20.351.20.1.153 | Columnfa8e1et100DefectCh3Remote | read-only | current | 8E1-ET100(T/S) Series card E1 channel 3 Defect Status: 0:No 1:Yes |
| 1.3.6.1.4.1.4756.20.351.20.1.154 | Columnfa8e1et100DefectCh4Remote | read-only | current | 8E1-ET100(T/S) Series card E1 channel 4 Defect Status: 0:No 1:Yes |
| 1.3.6.1.4.1.4756.20.351.20.1.155 | Columnfa8e1et100DefectCh5Remote | read-only | current | 8E1-ET100(T/S) Series card E1 channel 5 Defect Status: 0:No 1:Yes |
| 1.3.6.1.4.1.4756.20.351.20.1.156 | Columnfa8e1et100DefectCh6Remote | read-only | current | 8E1-ET100(T/S) Series card E1 channel 6 Defect Status: 0:No 1:Yes |
| 1.3.6.1.4.1.4756.20.351.20.1.157 | Columnfa8e1et100DefectCh7Remote | read-only | current | 8E1-ET100(T/S) Series card E1 channel 7 Defect Status: 0:No 1:Yes |
| 1.3.6.1.4.1.4756.20.351.20.1.158 | Columnfa8e1et100DefectCh8Remote | read-only | current | 8E1-ET100(T/S) Series card E1 channel 8 Defect Status: 0:No 1:Yes |
| 1.3.6.1.4.1.4756.20.351.20.1.159 | Columnfa8e1et100FxSignalRemote | read-only | current | 8E1-ET100(T/S) Series card Fiber signal detect(SD): 0:Fiber unplugged 1:Signal detected |
| 1.3.6.1.4.1.4756.20.351.20.1.160 | Columnfa8e1et100PortResetRemote | read-write | current | 8E1-ET100(T/S) Series card Port Reset: 0:Action 1:Off |
| 1.3.6.1.4.1.4756.20.351.20.1.161 | Columnfa8e1et100VLANModeRemote | read-write | current | 8E1-ET100(T/S) Series card VLAN mode: 0:MODE2 1:MODE1 |
| 1.3.6.1.4.1.4756.20.351.20.1.162 | Columnfa8e1et100ETagSelectEntryRemote | read-write | current | 8E1-ET100(T/S) Series card ETag select entry: |
| 1.3.6.1.4.1.4756.20.351.20.1.163 | Columnfa8e1et100ETagMethodRemote | read-write | current | 8E1-ET100(T/S) Series card ETag Method: 0: Intouch 1: Add Tag 2: Remove Tag |
| 1.3.6.1.4.1.4756.20.351.20.1.164 | Columnfa8e1et100VLANTableVID1Remote | read-write | current | 8E1-ET100(T/S) Series card VLAN Table: VLAN ID1 |
| 1.3.6.1.4.1.4756.20.351.20.1.165 | Columnfa8e1et100VLANTableVID2Remote | read-write | current | 8E1-ET100(T/S) Series card VLAN Table: VLAN ID2 |
| 1.3.6.1.4.1.4756.20.351.20.1.166 | Columnfa8e1et100VLANTableVID3Remote | read-write | current | 8E1-ET100(T/S) Series card VLAN Table: VLAN ID3 |
| 1.3.6.1.4.1.4756.20.351.20.1.167 | Columnfa8e1et100VLANTableVID4Remote | read-write | current | 8E1-ET100(T/S) Series card VLAN Table: VLAN ID4 |
| 1.3.6.1.4.1.4756.20.351.20.1.168 | Columnfa8e1et100VLANTableVID5Remote | read-write | current | 8E1-ET100(T/S) Series card VLAN Table: VLAN ID5 |
| 1.3.6.1.4.1.4756.20.351.20.1.169 | Columnfa8e1et100VLANTableVID6Remote | read-write | current | 8E1-ET100(T/S) Series card VLAN Table: VLAN ID6 |
| 1.3.6.1.4.1.4756.20.351.20.1.170 | Columnfa8e1et100VLANTableVID7Remote | read-write | current | 8E1-ET100(T/S) Series card VLAN Table: VLAN ID7 |
| 1.3.6.1.4.1.4756.20.351.20.1.171 | Columnfa8e1et100VLANTableVID8Remote | read-write | current | 8E1-ET100(T/S) Series card VLAN Table: VLAN ID8 |
| 1.3.6.1.4.1.4756.20.351.20.1.172 | Columnfa8e1et100VLANTableVID9Remote | read-write | current | 8E1-ET100(T/S) Series card VLAN Table: VLAN ID9 |
| 1.3.6.1.4.1.4756.20.351.20.1.173 | Columnfa8e1et100VLANTableVID10Remote | read-write | current | 8E1-ET100(T/S) Series card VLAN Table: VLAN ID10 |
| 1.3.6.1.4.1.4756.20.351.20.1.174 | Columnfa8e1et100VLANTableVID11Remote | read-write | current | 8E1-ET100(T/S) Series card VLAN Table: VLAN ID11 |
| 1.3.6.1.4.1.4756.20.351.20.1.175 | Columnfa8e1et100VLANTableVID12Remote | read-write | current | 8E1-ET100(T/S) Series card VLAN Table: VLAN ID12 |
| 1.3.6.1.4.1.4756.20.351.20.1.176 | Columnfa8e1et100VLANTableVID13Remote | read-write | current | 8E1-ET100(T/S) Series card VLAN Table: VLAN ID13 |
| 1.3.6.1.4.1.4756.20.351.20.1.177 | Columnfa8e1et100VLANTableVID14Remote | read-write | current | 8E1-ET100(T/S) Series card VLAN Table: VLAN ID14 |
| 1.3.6.1.4.1.4756.20.351.20.1.178 | Columnfa8e1et100VLANTableVID15Remote | read-write | current | 8E1-ET100(T/S) Series card VLAN Table: VLAN ID15 |
| 1.3.6.1.4.1.4756.20.351.20.1.179 | Columnfa8e1et100VLANTableVID16Remote | read-write | current | 8E1-ET100(T/S) Series card VLAN Table: VLAN ID16 |
| 1.3.6.1.4.1.4756.20.360 | Nodef16E1LocalCards | |||
| 1.3.6.1.4.1.4756.20.360.20 | Tablef16E1LocalTable | not-accessible | current | A list of local FRM220-16E1-ET100 series card entries. The number of entries is f16E1-No-L. |
| 1.3.6.1.4.1.4756.20.360.20.1 | Rowf16E1LocalEntry | not-accessible | current | An entry containing management information applicable to a particular local FRM220-16E1 series card. |
| 1.3.6.1.4.1.4756.20.360.20.1.1 | Columnfa16e1et100ChassisIndexLocal | read-only | current | A unique value for each card. It starts from 0 to 9 contiguously. |
| 1.3.6.1.4.1.4756.20.360.20.1.2 | Columnfa16e1et100SlotIndexLocal | read-only | current | A unique value for each card. It starts from 1 to 20 contiguously. |
| 1.3.6.1.4.1.4756.20.360.20.1.3 | Columnfa16e1et100CardHWVerLocal | read-only | current | 16E1-ET100(T/S) Series card hardware version x.xxx |
| 1.3.6.1.4.1.4756.20.360.20.1.4 | Columnfa16e1et100CardFWVerLocal | read-only | current | 16E1-ET100(T/S) Series card firmware version x.xxx |
| 1.3.6.1.4.1.4756.20.360.20.1.5 | Columnfa16e1et100CardCPLDVerLocal | read-only | current | 16E1-ET100(T/S) Series card CPLD version x.xxx |
| 1.3.6.1.4.1.4756.20.360.20.1.6 | Columnfa16e1et100CardFPGAVerLocal | read-only | current | 16E1-ET100(T/S) Series card FPGA version x.xxx |
| 1.3.6.1.4.1.4756.20.360.20.1.7 | Columnfa16e1et100ModelLocal | read-only | current | Card Type: 0:16E1-ET100T 1:16E1-ET100S |
| 1.3.6.1.4.1.4756.20.360.20.1.8 | Columnfa16e1et100SystemStatusLocal | read-only | current | 16E1-ET100(T/S) Series card system status: 0:Normal 1:Alarm |
| 1.3.6.1.4.1.4756.20.360.20.1.9 | Columnfa16e1et100DeviceActiveLocal | read-write | current | 16E1-ET100(T/S) Series card active: 0:Disable 1:Enable |
| 1.3.6.1.4.1.4756.20.360.20.1.10 | Columnfa16e1et100SetToDefaultLocal | read-write | current | 16E1-ET100(T/S) Series card port set to default: 0:Off 1:Trigger |
| 1.3.6.1.4.1.4756.20.360.20.1.11 | Columnfa16e1et100E1Ch1SingalLocal | read-only | current | 16E1-ET100(T/S) Series card E1 channel 1 signal status: 0:Singal Loss 1:Normal |
| 1.3.6.1.4.1.4756.20.360.20.1.12 | Columnfa16e1et100E1Ch2SingalLocal | read-only | current | 16E1-ET100(T/S) Series card E1 channel 2 signal status: 0:Singal Loss 1:Normal |
| 1.3.6.1.4.1.4756.20.360.20.1.13 | Columnfa16e1et100E1Ch3SingalLocal | read-only | current | 16E1-ET100(T/S) Series card E1 channel 3 signal status: 0:Singal Loss 1:Normal |
| 1.3.6.1.4.1.4756.20.360.20.1.14 | Columnfa16e1et100E1Ch4SingalLocal | read-only | current | 16E1-ET100(T/S) Series card E1 channel 4 signal status: 0:Singal Loss 1:Normal |
| 1.3.6.1.4.1.4756.20.360.20.1.15 | Columnfa16e1et100E1Ch5SingalLocal | read-only | current | 16E1-ET100(T/S) Series card E1 channel 5 signal status: 0:Singal Loss 1:Normal |
| 1.3.6.1.4.1.4756.20.360.20.1.16 | Columnfa16e1et100E1Ch6SingalLocal | read-only | current | 16E1-ET100(T/S) Series card E1 channel 6 signal status: 0:Singal Loss 1:Normal |
| 1.3.6.1.4.1.4756.20.360.20.1.17 | Columnfa16e1et100E1Ch7SingalLocal | read-only | current | 16E1-ET100(T/S) Series card E1 channel 7 signal status: 0:Singal Loss 1:Normal |
| 1.3.6.1.4.1.4756.20.360.20.1.18 | Columnfa16e1et100E1Ch8SingalLocal | read-only | current | 16E1-ET100(T/S) Series card E1 channel 8 signal status: 0:Singal Loss 1:Normal |
| 1.3.6.1.4.1.4756.20.360.20.1.19 | Columnfa16e1et100E1Ch9SingalLocal | read-only | current | 16E1-ET100(T/S) Series card E1 channel 9 signal status: 0:Singal Loss 1:Normal |
| 1.3.6.1.4.1.4756.20.360.20.1.20 | Columnfa16e1et100E1Ch10SingalLocal | read-only | current | 16E1-ET100(T/S) Series card E1 channel 10 signal status: 0:Singal Loss 1:Normal |
| 1.3.6.1.4.1.4756.20.360.20.1.21 | Columnfa16e1et100E1Ch11SingalLocal | read-only | current | 16E1-ET100(T/S) Series card E1 channel 11 signal status: 0:Singal Loss 1:Normal |
| 1.3.6.1.4.1.4756.20.360.20.1.22 | Columnfa16e1et100E1Ch12SingalLocal | read-only | current | 16E1-ET100(T/S) Series card E1 channel 12 signal status: 0:Singal Loss 1:Normal |
| 1.3.6.1.4.1.4756.20.360.20.1.23 | Columnfa16e1et100E1Ch13SingalLocal | read-only | current | 16E1-ET100(T/S) Series card E1 channel 13 signal status: 0:Singal Loss 1:Normal |
| 1.3.6.1.4.1.4756.20.360.20.1.24 | Columnfa16e1et100E1Ch14SingalLocal | read-only | current | 16E1-ET100(T/S) Series card E1 channel 14 signal status: 0:Singal Loss 1:Normal |
| 1.3.6.1.4.1.4756.20.360.20.1.25 | Columnfa16e1et100E1Ch15SingalLocal | read-only | current | 16E1-ET100(T/S) Series card E1 channel 15 signal status: 0:Singal Loss 1:Normal |
| 1.3.6.1.4.1.4756.20.360.20.1.26 | Columnfa16e1et100E1Ch16SingalLocal | read-only | current | 16E1-ET100(T/S) Series card E1 channel 16 signal status: 0:Singal Loss 1:Normal |
| 1.3.6.1.4.1.4756.20.360.20.1.27 | Columnfa16e1et100E1Ch1SyncLocal | read-only | current | 16E1-ET100(T/S) Series card E1 channel 1 sync status: 0:Sync Loss 1:Sync |
| 1.3.6.1.4.1.4756.20.360.20.1.28 | Columnfa16e1et100E1Ch2SyncLocal | read-only | current | 16E1-ET100(T/S) Series card E1 channel 2 sync status: 0:Sync Loss 1:Sync |
| 1.3.6.1.4.1.4756.20.360.20.1.29 | Columnfa16e1et100E1Ch3SyncLocal | read-only | current | 16E1-ET100(T/S) Series card E1 channel 3 sync status: 0:Sync Loss 1:Sync |
| 1.3.6.1.4.1.4756.20.360.20.1.30 | Columnfa16e1et100E1Ch4SyncLocal | read-only | current | 16E1-ET100(T/S) Series card E1 channel 4 sync status: 0:Sync Loss 1:Sync |
| 1.3.6.1.4.1.4756.20.360.20.1.31 | Columnfa16e1et100E1Ch5SyncLocal | read-only | current | 16E1-ET100(T/S) Series card E1 channel 5 sync status: 0:Sync Loss 1:Sync |
| 1.3.6.1.4.1.4756.20.360.20.1.32 | Columnfa16e1et100E1Ch6SyncLocal | read-only | current | 16E1-ET100(T/S) Series card E1 channel 6 sync status: 0:Sync Loss 1:Sync |
| 1.3.6.1.4.1.4756.20.360.20.1.33 | Columnfa16e1et100E1Ch7SyncLocal | read-only | current | 16E1-ET100(T/S) Series card E1 channel 7 sync status: 0:Sync Loss 1:Sync |
| 1.3.6.1.4.1.4756.20.360.20.1.34 | Columnfa16e1et100E1Ch8SyncLocal | read-only | current | 16E1-ET100(T/S) Series card E1 channel 8 sync status: 0:Sync Loss 1:Sync |
| 1.3.6.1.4.1.4756.20.360.20.1.35 | Columnfa16e1et100E1Ch9SyncLocal | read-only | current | 16E1-ET100(T/S) Series card E1 channel 9 sync status: 0:Sync Loss 1:Sync |
| 1.3.6.1.4.1.4756.20.360.20.1.36 | Columnfa16e1et100E1Ch10SyncLocal | read-only | current | 16E1-ET100(T/S) Series card E1 channel 10 sync status: 0:Sync Loss 1:Sync |
| 1.3.6.1.4.1.4756.20.360.20.1.37 | Columnfa16e1et100E1Ch11SyncLocal | read-only | current | 16E1-ET100(T/S) Series card E1 channel 11 sync status: 0:Sync Loss 1:Sync |
| 1.3.6.1.4.1.4756.20.360.20.1.38 | Columnfa16e1et100E1Ch12SyncLocal | read-only | current | 16E1-ET100(T/S) Series card E1 channel 12 sync status: 0:Sync Loss 1:Sync |
| 1.3.6.1.4.1.4756.20.360.20.1.39 | Columnfa16e1et100E1Ch13SyncLocal | read-only | current | 16E1-ET100(T/S) Series card E1 channel 13 sync status: 0:Sync Loss 1:Sync |
| 1.3.6.1.4.1.4756.20.360.20.1.40 | Columnfa16e1et100E1Ch14SyncLocal | read-only | current | 16E1-ET100(T/S) Series card E1 channel 14 sync status: 0:Sync Loss 1:Sync |
| 1.3.6.1.4.1.4756.20.360.20.1.41 | Columnfa16e1et100E1Ch15SyncLocal | read-only | current | 16E1-ET100(T/S) Series card E1 channel 15 sync status: 0:Sync Loss 1:Sync |
| 1.3.6.1.4.1.4756.20.360.20.1.42 | Columnfa16e1et100E1Ch16SyncLocal | read-only | current | 16E1-ET100(T/S) Series card E1 channel 16 sync status: 0:Sync Loss 1:Sync |
| 1.3.6.1.4.1.4756.20.360.20.1.43 | Columnfa16e1et100E1Ch1RecvAISLocal | read-only | current | 16E1-ET100(T/S) Series card E1 channel 1 receive AIS status: 0:No 1:Yes |
| 1.3.6.1.4.1.4756.20.360.20.1.44 | Columnfa16e1et100E1Ch2RecvAISLocal | read-only | current | 16E1-ET100(T/S) Series card E1 channel 2 receive AIS status: 0:No 1:Yes |
| 1.3.6.1.4.1.4756.20.360.20.1.45 | Columnfa16e1et100E1Ch3RecvAISLocal | read-only | current | 16E1-ET100(T/S) Series card E1 channel 3 receive AIS status: 0:No 1:Yes |
| 1.3.6.1.4.1.4756.20.360.20.1.46 | Columnfa16e1et100E1Ch4RecvAISLocal | read-only | current | 16E1-ET100(T/S) Series card E1 channel 4 receive AIS status: 0:No 1:Yes |
| 1.3.6.1.4.1.4756.20.360.20.1.47 | Columnfa16e1et100E1Ch5RecvAISLocal | read-only | current | 16E1-ET100(T/S) Series card E1 channel 5 receive AIS status: 0:No 1:Yes |
| 1.3.6.1.4.1.4756.20.360.20.1.48 | Columnfa16e1et100E1Ch6RecvAISLocal | read-only | current | 16E1-ET100(T/S) Series card E1 channel 6 receive AIS status: 0:No 1:Yes |
| 1.3.6.1.4.1.4756.20.360.20.1.49 | Columnfa16e1et100E1Ch7RecvAISLocal | read-only | current | 16E1-ET100(T/S) Series card E1 channel 7 receive AIS status: 0:No 1:Yes |
| 1.3.6.1.4.1.4756.20.360.20.1.50 | Columnfa16e1et100E1Ch8RecvAISLocal | read-only | current | 16E1-ET100(T/S) Series card E1 channel 8 receive AIS status: 0:No 1:Yes |
| 1.3.6.1.4.1.4756.20.360.20.1.51 | Columnfa16e1et100E1Ch9RecvAISLocal | read-only | current | 16E1-ET100(T/S) Series card E1 channel 9 receive AIS status: 0:No 1:Yes |
| 1.3.6.1.4.1.4756.20.360.20.1.52 | Columnfa16e1et100E1Ch10RecvAISLocal | read-only | current | 16E1-ET100(T/S) Series card E1 channel 10 receive AIS status: 0:No 1:Yes |
| 1.3.6.1.4.1.4756.20.360.20.1.53 | Columnfa16e1et100E1Ch11RecvAISLocal | read-only | current | 16E1-ET100(T/S) Series card E1 channel 11 receive AIS status: 0:No 1:Yes |
| 1.3.6.1.4.1.4756.20.360.20.1.54 | Columnfa16e1et100E1Ch12RecvAISLocal | read-only | current | 16E1-ET100(T/S) Series card E1 channel 12 receive AIS status: 0:No 1:Yes |
| 1.3.6.1.4.1.4756.20.360.20.1.55 | Columnfa16e1et100E1Ch13RecvAISLocal | read-only | current | 16E1-ET100(T/S) Series card E1 channel 13 receive AIS status: 0:No 1:Yes |
| 1.3.6.1.4.1.4756.20.360.20.1.56 | Columnfa16e1et100E1Ch14RecvAISLocal | read-only | current | 16E1-ET100(T/S) Series card E1 channel 14 receive AIS status: 0:No 1:Yes |
| 1.3.6.1.4.1.4756.20.360.20.1.57 | Columnfa16e1et100E1Ch15RecvAISLocal | read-only | current | 16E1-ET100(T/S) Series card E1 channel 15 receive AIS status: 0:No 1:Yes |
| 1.3.6.1.4.1.4756.20.360.20.1.58 | Columnfa16e1et100E1Ch16RecvAISLocal | read-only | current | 16E1-ET100(T/S) Series card E1 channel 16 receive AIS status: 0:No 1:Yes |
| 1.3.6.1.4.1.4756.20.360.20.1.59 | Columnfa16e1et100E1Ch1ConnTypeLocal | read-only | current | 16E1-ET100(T/S) Series card E1 channel 1 connector type: 0:RJ-48C 1:BNC |
| 1.3.6.1.4.1.4756.20.360.20.1.60 | Columnfa16e1et100E1Ch2ConnTypeLocal | read-only | current | 16E1-ET100(T/S) Series card E1 channel 2 connector type: 0:RJ-48C 1:BNC |
| 1.3.6.1.4.1.4756.20.360.20.1.61 | Columnfa16e1et100E1Ch3ConnTypeLocal | read-only | current | 16E1-ET100(T/S) Series card E1 channel 3 connector type: 0:RJ-48C 1:BNC |
| 1.3.6.1.4.1.4756.20.360.20.1.62 | Columnfa16e1et100E1Ch4ConnTypeLocal | read-only | current | 16E1-ET100(T/S) Series card E1 channel 4 connector type: 0:RJ-48C 1:BNC |
| 1.3.6.1.4.1.4756.20.360.20.1.63 | Columnfa16e1et100E1Ch5ConnTypeLocal | read-only | current | 16E1-ET100(T/S) Series card E1 channel 5 connector type: 0:RJ-48C 1:BNC |
| 1.3.6.1.4.1.4756.20.360.20.1.64 | Columnfa16e1et100E1Ch6ConnTypeLocal | read-only | current | 16E1-ET100(T/S) Series card E1 channel 6 connector type: 0:RJ-48C 1:BNC |
| 1.3.6.1.4.1.4756.20.360.20.1.65 | Columnfa16e1et100E1Ch7ConnTypeLocal | read-only | current | 16E1-ET100(T/S) Series card E1 channel 7 connector type: 0:RJ-48C 1:BNC |
| 1.3.6.1.4.1.4756.20.360.20.1.66 | Columnfa16e1et100E1Ch8ConnTypeLocal | read-only | current | 16E1-ET100(T/S) Series card E1 channel 8 connector type: 0:RJ-48C 1:BNC |
| 1.3.6.1.4.1.4756.20.360.20.1.67 | Columnfa16e1et100E1Ch9ConnTypeLocal | read-only | current | 16E1-ET100(T/S) Series card E1 channel 9 connector type: 0:RJ-48C 1:BNC |
| 1.3.6.1.4.1.4756.20.360.20.1.68 | Columnfa16e1et100E1Ch10ConnTypeLocal | read-only | current | 16E1-ET100(T/S) Series card E1 channel 10 connector type: 0:RJ-48C 1:BNC |
| 1.3.6.1.4.1.4756.20.360.20.1.69 | Columnfa16e1et100E1Ch11ConnTypeLocal | read-only | current | 16E1-ET100(T/S) Series card E1 channel 11 connector type: 0:RJ-48C 1:BNC |
| 1.3.6.1.4.1.4756.20.360.20.1.70 | Columnfa16e1et100E1Ch12ConnTypeLocal | read-only | current | 16E1-ET100(T/S) Series card E1 channel 12 connector type: 0:RJ-48C 1:BNC |
| 1.3.6.1.4.1.4756.20.360.20.1.71 | Columnfa16e1et100E1Ch13ConnTypeLocal | read-only | current | 16E1-ET100(T/S) Series card E1 channel 13 connector type: 0:RJ-48C 1:BNC |
| 1.3.6.1.4.1.4756.20.360.20.1.72 | Columnfa16e1et100E1Ch14ConnTypeLocal | read-only | current | 16E1-ET100(T/S) Series card E1 channel 14 connector type: 0:RJ-48C 1:BNC |
| 1.3.6.1.4.1.4756.20.360.20.1.73 | Columnfa16e1et100E1Ch15ConnTypeLocal | read-only | current | 16E1-ET100(T/S) Series card E1 channel 15 connector type: 0:RJ-48C 1:BNC |
| 1.3.6.1.4.1.4756.20.360.20.1.74 | Columnfa16e1et100E1Ch16ConnTypeLocal | read-only | current | 16E1-ET100(T/S) Series card E1 channel 16 connector type: 0:RJ-48C 1:BNC |
| 1.3.6.1.4.1.4756.20.360.20.1.75 | Columnfa16e1et100E1Ch1RAILocal | read-only | current | 16E1-ET100(T/S) Series card E1 channel 1 RAI status: 0:No 1:Yes |
| 1.3.6.1.4.1.4756.20.360.20.1.76 | Columnfa16e1et100E1Ch2RAILocal | read-only | current | 16E1-ET100(T/S) Series card E1 channel 2 RAI status: 0:No 1:Yes |
| 1.3.6.1.4.1.4756.20.360.20.1.77 | Columnfa16e1et100E1Ch3RAILocal | read-only | current | 16E1-ET100(T/S) Series card E1 channel 3 RAI status: 0:No 1:Yes |
| 1.3.6.1.4.1.4756.20.360.20.1.78 | Columnfa16e1et100E1Ch4RAILocal | read-only | current | 16E1-ET100(T/S) Series card E1 channel 4 RAI status: 0:No 1:Yes |
| 1.3.6.1.4.1.4756.20.360.20.1.79 | Columnfa16e1et100E1Ch5RAILocal | read-only | current | 16E1-ET100(T/S) Series card E1 channel 5 RAI status: 0:No 1:Yes |
| 1.3.6.1.4.1.4756.20.360.20.1.80 | Columnfa16e1et100E1Ch6RAILocal | read-only | current | 16E1-ET100(T/S) Series card E1 channel 6 RAI status: 0:No 1:Yes |
| 1.3.6.1.4.1.4756.20.360.20.1.81 | Columnfa16e1et100E1Ch7RAILocal | read-only | current | 16E1-ET100(T/S) Series card E1 channel 7 RAI status: 0:No 1:Yes |
| 1.3.6.1.4.1.4756.20.360.20.1.82 | Columnfa16e1et100E1Ch8RAILocal | read-only | current | 16E1-ET100(T/S) Series card E1 channel 8 RAI status: 0:No 1:Yes |
| 1.3.6.1.4.1.4756.20.360.20.1.83 | Columnfa16e1et100E1Ch9RAILocal | read-only | current | 16E1-ET100(T/S) Series card E1 channel 9 RAI status: 0:No 1:Yes |
| 1.3.6.1.4.1.4756.20.360.20.1.84 | Columnfa16e1et100E1Ch10RAILocal | read-only | current | 16E1-ET100(T/S) Series card E1 channel 10 RAI status: 0:No 1:Yes |
| 1.3.6.1.4.1.4756.20.360.20.1.85 | Columnfa16e1et100E1Ch11RAILocal | read-only | current | 16E1-ET100(T/S) Series card E1 channel 11 RAI status: 0:No 1:Yes |
| 1.3.6.1.4.1.4756.20.360.20.1.86 | Columnfa16e1et100E1Ch12RAILocal | read-only | current | 16E1-ET100(T/S) Series card E1 channel 12 RAI status: 0:No 1:Yes |
| 1.3.6.1.4.1.4756.20.360.20.1.87 | Columnfa16e1et100E1Ch13RAILocal | read-only | current | 16E1-ET100(T/S) Series card E1 channel 13 RAI status: 0:No 1:Yes |
| 1.3.6.1.4.1.4756.20.360.20.1.88 | Columnfa16e1et100E1Ch14RAILocal | read-only | current | 16E1-ET100(T/S) Series card E1 channel 14 RAI status: 0:No 1:Yes |
| 1.3.6.1.4.1.4756.20.360.20.1.89 | Columnfa16e1et100E1Ch15RAILocal | read-only | current | 16E1-ET100(T/S) Series card E1 channel 15 RAI status: 0:No 1:Yes |
| 1.3.6.1.4.1.4756.20.360.20.1.90 | Columnfa16e1et100E1Ch16RAILocal | read-only | current | 16E1-ET100(T/S) Series card E1 channel 16 RAI status: 0:No 1:Yes |
| 1.3.6.1.4.1.4756.20.360.20.1.91 | Columnfa16e1et100E1Ch1LOMFLocal | read-only | current | 16E1-ET100(T/S) Series card E1 channel 1 LOMF status: 0:No 1:Yes |
| 1.3.6.1.4.1.4756.20.360.20.1.92 | Columnfa16e1et100E1Ch2LOMFLocal | read-only | current | 16E1-ET100(T/S) Series card E1 channel 2 LOMF status: 0:No 1:Yes |
| 1.3.6.1.4.1.4756.20.360.20.1.93 | Columnfa16e1et100E1Ch3LOMFLocal | read-only | current | 16E1-ET100(T/S) Series card E1 channel 3 LOMF status: 0:No 1:Yes |
| 1.3.6.1.4.1.4756.20.360.20.1.94 | Columnfa16e1et100E1Ch4LOMFLocal | read-only | current | 16E1-ET100(T/S) Series card E1 channel 4 LOMF status: 0:No 1:Yes |
| 1.3.6.1.4.1.4756.20.360.20.1.95 | Columnfa16e1et100E1Ch5LOMFLocal | read-only | current | 16E1-ET100(T/S) Series card E1 channel 5 LOMF status: 0:No 1:Yes |
| 1.3.6.1.4.1.4756.20.360.20.1.96 | Columnfa16e1et100E1Ch6LOMFLocal | read-only | current | 16E1-ET100(T/S) Series card E1 channel 6 LOMF status: 0:No 1:Yes |
| 1.3.6.1.4.1.4756.20.360.20.1.97 | Columnfa16e1et100E1Ch7LOMFLocal | read-only | current | 16E1-ET100(T/S) Series card E1 channel 7 LOMF status: 0:No 1:Yes |
| 1.3.6.1.4.1.4756.20.360.20.1.98 | Columnfa16e1et100E1Ch8LOMFLocal | read-only | current | 16E1-ET100(T/S) Series card E1 channel 8 LOMF status: 0:No 1:Yes |
| 1.3.6.1.4.1.4756.20.360.20.1.99 | Columnfa16e1et100E1Ch9LOMFLocal | read-only | current | 16E1-ET100(T/S) Series card E1 channel 9 LOMF status: 0:No 1:Yes |
| 1.3.6.1.4.1.4756.20.360.20.1.100 | Columnfa16e1et100E1Ch10LOMFLocal | read-only | current | 16E1-ET100(T/S) Series card E1 channel 10 LOMF status: 0:No 1:Yes |
| 1.3.6.1.4.1.4756.20.360.20.1.101 | Columnfa16e1et100E1Ch11LOMFLocal | read-only | current | 16E1-ET100(T/S) Series card E1 channel 11 LOMF status: 0:No 1:Yes |
| 1.3.6.1.4.1.4756.20.360.20.1.102 | Columnfa16e1et100E1Ch12LOMFLocal | read-only | current | 16E1-ET100(T/S) Series card E1 channel 12 LOMF status: 0:No 1:Yes |
| 1.3.6.1.4.1.4756.20.360.20.1.103 | Columnfa16e1et100E1Ch13LOMFLocal | read-only | current | 16E1-ET100(T/S) Series card E1 channel 13 LOMF status: 0:No 1:Yes |
| 1.3.6.1.4.1.4756.20.360.20.1.104 | Columnfa16e1et100E1Ch14LOMFLocal | read-only | current | 16E1-ET100(T/S) Series card E1 channel 14 LOMF status: 0:No 1:Yes |
| 1.3.6.1.4.1.4756.20.360.20.1.105 | Columnfa16e1et100E1Ch15LOMFLocal | read-only | current | 16E1-ET100(T/S) Series card E1 channel 15 LOMF status: 0:No 1:Yes |
| 1.3.6.1.4.1.4756.20.360.20.1.106 | Columnfa16e1et100E1Ch16LOMFLocal | read-only | current | 16E1-ET100(T/S) Series card E1 channel 16 LOMF status: 0:No 1:Yes |
| 1.3.6.1.4.1.4756.20.360.20.1.107 | Columnfa16e1et100E1Ch1ActiveLocal | read-only | current | 16E1-ET100(T/S) Series card E1 channel 1 active status: 0:Inactive 1:Active |
| 1.3.6.1.4.1.4756.20.360.20.1.108 | Columnfa16e1et100E1Ch2ActiveLocal | read-only | current | 16E1-ET100(T/S) Series card E1 channel 2 active status: 0:Inactive 1:Active |
| 1.3.6.1.4.1.4756.20.360.20.1.109 | Columnfa16e1et100E1Ch3ActiveLocal | read-only | current | 16E1-ET100(T/S) Series card E1 channel 3 active status: 0:Inactive 1:Active |
| 1.3.6.1.4.1.4756.20.360.20.1.110 | Columnfa16e1et100E1Ch4ActiveLocal | read-only | current | 16E1-ET100(T/S) Series card E1 channel 4 active status: 0:Inactive 1:Active |
| 1.3.6.1.4.1.4756.20.360.20.1.111 | Columnfa16e1et100E1Ch5ActiveLocal | read-only | current | 16E1-ET100(T/S) Series card E1 channel 5 active status: 0:Inactive 1:Active |
| 1.3.6.1.4.1.4756.20.360.20.1.112 | Columnfa16e1et100E1Ch6ActiveLocal | read-only | current | 16E1-ET100(T/S) Series card E1 channel 6 active status: 0:Inactive 1:Active |
| 1.3.6.1.4.1.4756.20.360.20.1.113 | Columnfa16e1et100E1Ch7ActiveLocal | read-only | current | 16E1-ET100(T/S) Series card E1 channel 7 active status: 0:Inactive 1:Active |
| 1.3.6.1.4.1.4756.20.360.20.1.114 | Columnfa16e1et100E1Ch8ActiveLocal | read-only | current | 16E1-ET100(T/S) Series card E1 channel 8 active status: 0:Inactive 1:Active |
| 1.3.6.1.4.1.4756.20.360.20.1.115 | Columnfa16e1et100E1Ch9ActiveLocal | read-only | current | 16E1-ET100(T/S) Series card E1 channel 9 active status: 0:Inactive 1:Active |
| 1.3.6.1.4.1.4756.20.360.20.1.116 | Columnfa16e1et100E1Ch10ActiveLocal | read-only | current | 16E1-ET100(T/S) Series card E1 channel 10 active status: 0:Inactive 1:Active |
| 1.3.6.1.4.1.4756.20.360.20.1.117 | Columnfa16e1et100E1Ch11ActiveLocal | read-only | current | 16E1-ET100(T/S) Series card E1 channel 11 active status: 0:Inactive 1:Active |
| 1.3.6.1.4.1.4756.20.360.20.1.118 | Columnfa16e1et100E1Ch12ActiveLocal | read-only | current | 16E1-ET100(T/S) Series card E1 channel 12 active status: 0:Inactive 1:Active |
| 1.3.6.1.4.1.4756.20.360.20.1.119 | Columnfa16e1et100E1Ch13ActiveLocal | read-only | current | 16E1-ET100(T/S) Series card E1 channel 13 active status: 0:Inactive 1:Active |
| 1.3.6.1.4.1.4756.20.360.20.1.120 | Columnfa16e1et100E1Ch14ActiveLocal | read-only | current | 16E1-ET100(T/S) Series card E1 channel 14 active status: 0:Inactive 1:Active |
| 1.3.6.1.4.1.4756.20.360.20.1.121 | Columnfa16e1et100E1Ch15ActiveLocal | read-only | current | 16E1-ET100(T/S) Series card E1 channel 15 active status: 0:Inactive 1:Active |
| 1.3.6.1.4.1.4756.20.360.20.1.122 | Columnfa16e1et100E1Ch16ActiveLocal | read-only | current | 16E1-ET100(T/S) Series card E1 channel 16 active status: 0:Inactive 1:Active |
| 1.3.6.1.4.1.4756.20.360.20.1.123 | Columnfa16e1et100E1Ch1LoopBackLocal | read-write | current | 16E1-ET100(T/S) Series card port E1 channel 1 loop back: 0:Off 2:RLB (Max used 15 channels) |
| 1.3.6.1.4.1.4756.20.360.20.1.124 | Columnfa16e1et100E1Ch2LoopBackLocal | read-write | current | 16E1-ET100(T/S) Series card port E1 channel 2 loop back: 0:Off 2:RLB (Max used 15 channels) |
| 1.3.6.1.4.1.4756.20.360.20.1.125 | Columnfa16e1et100E1Ch3LoopBackLocal | read-write | current | 16E1-ET100(T/S) Series card port E1 channel 3 loop back: 0:Off 2:RLB (Max used 15 channels) |
| 1.3.6.1.4.1.4756.20.360.20.1.126 | Columnfa16e1et100E1Ch4LoopBackLocal | read-write | current | 16E1-ET100(T/S) Series card port E1 channel 4 loop back: 0:Off 2:RLB (Max used 15 channels) |
| 1.3.6.1.4.1.4756.20.360.20.1.127 | Columnfa16e1et100E1Ch5LoopBackLocal | read-write | current | 16E1-ET100(T/S) Series card port E1 channel 5 loop back: 0:Off 2:RLB (Max used 15 channels) |
| 1.3.6.1.4.1.4756.20.360.20.1.128 | Columnfa16e1et100E1Ch6LoopBackLocal | read-write | current | 16E1-ET100(T/S) Series card port E1 channel 6 loop back: 0:Off 2:RLB (Max used 15 channels) |
| 1.3.6.1.4.1.4756.20.360.20.1.129 | Columnfa16e1et100E1Ch7LoopBackLocal | read-write | current | 16E1-ET100(T/S) Series card port E1 channel 7 loop back: 0:Off 2:RLB (Max used 15 channels) |
| 1.3.6.1.4.1.4756.20.360.20.1.130 | Columnfa16e1et100E1Ch8LoopBackLocal | read-write | current | 16E1-ET100(T/S) Series card port E1 channel 8 loop back: 0:Off 2:RLB (Max used 15 channels) |
| 1.3.6.1.4.1.4756.20.360.20.1.131 | Columnfa16e1et100E1Ch9LoopBackLocal | read-write | current | 16E1-ET100(T/S) Series card port E1 channel 9 loop back: 0:Off 2:RLB (Max used 15 channels) |
| 1.3.6.1.4.1.4756.20.360.20.1.132 | Columnfa16e1et100E1Ch10LoopBackLocal | read-write | current | 16E1-ET100(T/S) Series card port E1 channel 10 loop back: 0:Off 2:RLB (Max used 15 channels) |
| 1.3.6.1.4.1.4756.20.360.20.1.133 | Columnfa16e1et100E1Ch11LoopBackLocal | read-write | current | 16E1-ET100(T/S) Series card port E1 channel 11 loop back: 0:Off 2:RLB (Max used 15 channels) |
| 1.3.6.1.4.1.4756.20.360.20.1.134 | Columnfa16e1et100E1Ch12LoopBackLocal | read-write | current | 16E1-ET100(T/S) Series card port E1 channel 12 loop back: 0:Off 2:RLB (Max used 15 channels) |
| 1.3.6.1.4.1.4756.20.360.20.1.135 | Columnfa16e1et100E1Ch13LoopBackLocal | read-write | current | 16E1-ET100(T/S) Series card port E1 channel 13 loop back: 0:Off 2:RLB (Max used 15 channels) |
| 1.3.6.1.4.1.4756.20.360.20.1.136 | Columnfa16e1et100E1Ch14LoopBackLocal | read-write | current | 16E1-ET100(T/S) Series card port E1 channel 14 loop back: 0:Off 2:RLB (Max used 15 channels) |
| 1.3.6.1.4.1.4756.20.360.20.1.137 | Columnfa16e1et100E1Ch15LoopBackLocal | read-write | current | 16E1-ET100(T/S) Series card port E1 channel 15 loop back: 0:Off 2:RLB (Max used 15 channels) |
| 1.3.6.1.4.1.4756.20.360.20.1.138 | Columnfa16e1et100E1Ch16LoopBackLocal | read-write | current | 16E1-ET100(T/S) Series card port E1 channel 16 loop back: 0:Off 2:RLB (Max used 15 channels) |
| 1.3.6.1.4.1.4756.20.360.20.1.139 | Columnfa16e1et100FxLinkLocal | read-only | current | 16E1-ET100S Series card Fiber siganl detect status: 0:Down or Fiber unplugged 1:Up or Singal detected |
| 1.3.6.1.4.1.4756.20.360.20.1.140 | Columnfa16e1et100FxLaserLocal | read-only | current | 16E1-ET100S Series card laser status: 0:Normal 1:Error |
| 1.3.6.1.4.1.4756.20.360.20.1.141 | Columnfa16e1et100FxActiveLocal | read-write | current | 16E1-ET100S Series card Fiber active: 0:Inactive 1:Active |
| 1.3.6.1.4.1.4756.20.360.20.1.142 | Columnfa16e1et100FxLaserOutputLocal | read-write | current | 16E1-ET100S Series card laser output: 0:disable 1:Enable |
| 1.3.6.1.4.1.4756.20.360.20.1.143 | Columnfa16e1et100FxOpModeLocal | read-write | current | 16E1-ET100S Series card operation mode: 0:Switch 1:Convert |
| 1.3.6.1.4.1.4756.20.360.20.1.144 | Columnfa16e1et100UtpLinkLocal | read-only | current | 16E1-ET100T Series card UTP link status: 0:Link Down 1:Link Up |
| 1.3.6.1.4.1.4756.20.360.20.1.145 | Columnfa16e1et100UtpStatusLocal | read-only | current | 16E1-ET100T Series card UTP link mode status: 0:None, Maybe link down 1:Link at 10Mbps, Half duplex 2:Link at 10Mbps, Full duplex 3:Link at 100Mbps, Half duple… |
| 1.3.6.1.4.1.4756.20.360.20.1.146 | Columnfa16e1et100UtpFlowCtrlStsLocal | read-only | current | 16E1-ET100T Series card UTP flow control status: 0:Disable 1:Enable |
| 1.3.6.1.4.1.4756.20.360.20.1.147 | Columnfa16e1et100UtpModeLocal | read-write | current | 16E1-ET100T Series card UTP mode: 0:Disable 1:Enable and autoNegotiation 3:Enable and force to 10Mbps, Half duplex 4:Enable and force to 10Mbps, Full duplex 5:… |
| 1.3.6.1.4.1.4756.20.360.20.1.148 | Columnfa16e1et100UtpFlowCtrlLocal | read-write | current | 16E1-ET100T Series card UTP flow control: 0:Disable 1:Enable |
| 1.3.6.1.4.1.4756.20.360.20.1.149 | Columnfa16e1et100SpeedLimitLocal | read-write | current | 16E1-ET100(T/S) Series card speed limit: Limited = this value * 32Kbps, this value is restricted to 0 ~ 3125, 0 to disable |
| 1.3.6.1.4.1.4756.20.360.20.1.150 | Columnfa16e1et100VlanAwareLocal | read-write | current | 16E1-ET100(T/S) Series card 802.1q VLAN tag aware: 0:Disable 1:Enable |
| 1.3.6.1.4.1.4756.20.360.20.1.151 | Columnfa16e1et100VlanIDLocal | read-write | current | 16E1-ET100(T/S) Series card VLAN ID: The ID is restricted to 1 ~ 4094 |
| 1.3.6.1.4.1.4756.20.360.20.1.152 | Columnfa16e1et100RemoteDeviceLocal | read-only | current | FRM220A-16E1 Series card remote device status: 0:Link Down 1:Link Up |
| 1.3.6.1.4.1.4756.20.360.20.1.153 | Columnfa16e1et100RemotePowerLocal | read-only | current | 16E1-ET100(T/S) Series card remote device power status: 0:Normal 1:Power off |
| 1.3.6.1.4.1.4756.20.360.20.1.154 | Columnfa16e1et100TimingSourceLocal | read-write | current | 16E1-ET100(T/S) Series card clock: 0:Internal oscillatro 1:Recovery from E1 channel 1 2:Recovery from E1 channel 2 3:Recovery from E1 channel 3 4:Recovery from… |
| 1.3.6.1.4.1.4756.20.360.20.1.155 | Columnfa16e1et100FCSofGFPLocal | read-write | current | 16E1-ET100(T/S) Series card FCS of GFP: 0:Disable 1:Enable |
| 1.3.6.1.4.1.4756.20.360.20.1.156 | Columnfa16e1et100AutoChAdjustLocal | read-write | current | 16E1-ET100(T/S) Series card auto channel Bdjust: 0:Disable 1:Enable |
| 1.3.6.1.4.1.4756.20.360.20.1.157 | Columnfa16e1et100PayloadScrambleLocal | read-write | current | 16E1-ET100(T/S) Series card payload scramble: 0:Disable 1:Enable |
| 1.3.6.1.4.1.4756.20.360.20.1.158 | Columnfa16e1et100FailoverLocal | read-write | current | 16E1-ET100(T/S) Series card failover: 0:Disable 1:Enable |
| 1.3.6.1.4.1.4756.20.360.20.1.159 | Columnfa16e1et100LOMLocal | read-only | current | 16E1-ET100(T/S) Series card LOM status: 0:No 1:Yes |
| 1.3.6.1.4.1.4756.20.360.20.1.160 | Columnfa16e1et100SQMLocal | read-only | current | 16E1-ET100(T/S) Series card SQM status: 0:No 1:Yes |
| 1.3.6.1.4.1.4756.20.360.20.1.161 | Columnfa16e1et100CRCLocal | read-only | current | 16E1-ET100(T/S) Series card CRC status: 0:No 1:Yes |
| 1.3.6.1.4.1.4756.20.360.20.1.162 | Columnfa16e1et100LOALocal | read-only | current | 16E1-ET100(T/S) Series card LOA status: 0:No 1:Yes |
| 1.3.6.1.4.1.4756.20.360.20.1.163 | Columnfa16e1et100LFDLocal | read-only | current | 16E1-ET100(T/S) Series card LFD status: 0:No 1:Yes |
| 1.3.6.1.4.1.4756.20.360.20.1.164 | Columnfa16e1et100DDTOLocal | read-only | current | 16E1-ET100(T/S) Series card DDTO status: 0:No 1:Yes |
| 1.3.6.1.4.1.4756.20.360.20.1.165 | Columnfa16e1et100VcatMember1Local | read-write | current | 16E1-ET100(T/S) Series card VACT member 1: 0:Disable 1:Enable |
| 1.3.6.1.4.1.4756.20.360.20.1.166 | Columnfa16e1et100VcatMember2Local | read-write | current | 16E1-ET100(T/S) Series card VACT member 2: 0:Disable 1:Enable |
| 1.3.6.1.4.1.4756.20.360.20.1.167 | Columnfa16e1et100VcatMember3Local | read-write | current | 16E1-ET100(T/S) Series card VACT member 3: 0:Disable 1:Enable |
| 1.3.6.1.4.1.4756.20.360.20.1.168 | Columnfa16e1et100VcatMember4Local | read-write | current | 16E1-ET100(T/S) Series card VACT member 4: 0:Disable 1:Enable |
| 1.3.6.1.4.1.4756.20.360.20.1.169 | Columnfa16e1et100VcatMember5Local | read-write | current | 16E1-ET100(T/S) Series card VACT member 5: 0:Disable 1:Enable |
| 1.3.6.1.4.1.4756.20.360.20.1.170 | Columnfa16e1et100VcatMember6Local | read-write | current | 16E1-ET100(T/S) Series card VACT member 6: 0:Disable 1:Enable |
| 1.3.6.1.4.1.4756.20.360.20.1.171 | Columnfa16e1et100VcatMember7Local | read-write | current | 16E1-ET100(T/S) Series card VACT member 7: 0:Disable 1:Enable |
| 1.3.6.1.4.1.4756.20.360.20.1.172 | Columnfa16e1et100VcatMember8Local | read-write | current | 16E1-ET100(T/S) Series card VACT member 8: 0:Disable 1:Enable |
| 1.3.6.1.4.1.4756.20.360.20.1.173 | Columnfa16e1et100VcatMember9Local | read-write | current | 16E1-ET100(T/S) Series card VACT member 9: 0:Disable 1:Enable |
| 1.3.6.1.4.1.4756.20.360.20.1.174 | Columnfa16e1et100VcatMember10Local | read-write | current | 16E1-ET100(T/S) Series card VACT member 10: 0:Disable 1:Enable |
| 1.3.6.1.4.1.4756.20.360.20.1.175 | Columnfa16e1et100VcatMember11Local | read-write | current | 16E1-ET100(T/S) Series card VACT member 11: 0:Disable 1:Enable |
| 1.3.6.1.4.1.4756.20.360.20.1.176 | Columnfa16e1et100VcatMember12Local | read-write | current | 16E1-ET100(T/S) Series card VACT member 12: 0:Disable 1:Enable |
| 1.3.6.1.4.1.4756.20.360.20.1.177 | Columnfa16e1et100VcatMember13Local | read-write | current | 16E1-ET100(T/S) Series card VACT member 13: 0:Disable 1:Enable |
| 1.3.6.1.4.1.4756.20.360.20.1.178 | Columnfa16e1et100VcatMember14Local | read-write | current | 16E1-ET100(T/S) Series card VACT member 14: 0:Disable 1:Enable |
| 1.3.6.1.4.1.4756.20.360.20.1.179 | Columnfa16e1et100VcatMember15Local | read-write | current | 16E1-ET100(T/S) Series card VACT member 15: 0:Disable 1:Enable |
| 1.3.6.1.4.1.4756.20.360.20.1.180 | Columnfa16e1et100VcatMember16Local | read-write | current | 16E1-ET100(T/S) Series card VACT member 16: 0:Disable 1:Enable |
| 1.3.6.1.4.1.4756.20.360.20.1.181 | Columnfa16e1et100SnmpChannel1Local | read-write | current | 16E1-ET100(T/S) Series card SNMP channel 0: 0:No use 1:Use |
| 1.3.6.1.4.1.4756.20.360.20.1.182 | Columnfa16e1et100SnmpChannel2Local | read-write | current | 16E1-ET100(T/S) Series card SNMP channel 1: 0:No use 1:Use |
| 1.3.6.1.4.1.4756.20.360.20.1.183 | Columnfa16e1et100SnmpChannel3Local | read-write | current | 16E1-ET100(T/S) Series card SNMP channel 3: 0:No use 1:Use |
| 1.3.6.1.4.1.4756.20.360.20.1.184 | Columnfa16e1et100SnmpChannel4Local | read-write | current | 16E1-ET100(T/S) Series card SNMP channel 4: 0:No use 1:Use |
| 1.3.6.1.4.1.4756.20.360.20.1.185 | Columnfa16e1et100ErrSecLocal | read-only | current | 16E1-ET100(T/S) Series card, errored seconds of BERT result. |
| 1.3.6.1.4.1.4756.20.360.20.1.186 | Columnfa16e1et100ErrFreeSecLocal | read-only | current | 16E1-ET100(T/S) Series card, errored free seconds of BERT result. |
| 1.3.6.1.4.1.4756.20.360.20.1.187 | Columnfa16e1et100ServErrSecLocal | read-only | current | 16E1-ET100(T/S) Series card, severely errored seconds of BERT result. |
| 1.3.6.1.4.1.4756.20.360.20.1.188 | Columnfa16e1et100BertFunctionLocal | read-write | current | 16E1-ET100(T/S) Series card bert function: 0:Disable 1:Enable |
| 1.3.6.1.4.1.4756.20.360.20.1.189 | Columnfa16e1et100ClrBertDataLocal | read-write | current | 16E1-ET100(T/S) Series card bert data clear: 0:Normal 1:Clear |
| 1.3.6.1.4.1.4756.20.360.20.1.190 | Columnfa16e1et100BertE1ChannelLocal | read-write | current | 16E1-ET100(T/S) Series card bert E1 channel number: 0:E1 channel 1 1:E1 channel 2 2:E1 channel 3 3:E1 channel 4 4:E1 channel 5 5:E1 channel 6 6:E1 channel 7 7:… |
| 1.3.6.1.4.1.4756.20.360.20.1.191 | Columnfa16e1et100RmonFunctionLocal | read-write | current | 16E1-ET100(T/S) Series RMON function : 0:Disable 1:Enable |
| 1.3.6.1.4.1.4756.20.360.20.1.192 | Columnfa16e1et100RmonTxLocal | read-only | current | 16E1-ET100(T/S) Series card RMON Tx counter. |
| 1.3.6.1.4.1.4756.20.360.20.1.193 | Columnfa16e1et100RmonRxLocal | read-only | current | 16E1-ET100(T/S) Series card RMON Rx counter. |
| 1.3.6.1.4.1.4756.20.360.20.1.194 | Columnfa16e1et100ClrRmonTxLocal | read-write | current | 16E1-ET100(T/S) Series card clear RMON Tx counter: 0:Normal 1:Clear |
| 1.3.6.1.4.1.4756.20.360.20.1.195 | Columnfa16e1et100ClrRmonRxLocal | read-write | current | 16E1-ET100(T/S) Series card clear RMON Rx counter: 0:Normal 1:Clear |
| 1.3.6.1.4.1.4756.20.360.20.1.196 | Columnfa16e1et100SfpLocal | read-only | current | 16E1-ET100(T/S) Series card, SFP existed: 0:No 1:Yes |
| 1.3.6.1.4.1.4756.20.360.20.1.197 | Columnfa16e1et100SfpVendorLocal | read-only | current | 16E1-ET100(T/S) Series card, Vendor name of SFP. |
| 1.3.6.1.4.1.4756.20.360.20.1.198 | Columnfa16e1et100SfpPartNoLocal | read-only | current | 16E1-ET100(T/S) Series card, Vendor part number of SFP. |
| 1.3.6.1.4.1.4756.20.360.20.1.199 | Columnfa16e1et100SfpFiberTypeLocal | read-only | current | 16E1-ET100(T/S) Series card, Fiber Type of SFP. |
| 1.3.6.1.4.1.4756.20.360.20.1.200 | Columnfa16e1et100SfpTxWaveLenLocal | read-only | current | 16E1-ET100(T/S) Series card, Tx Wave length of SFP. |
| 1.3.6.1.4.1.4756.20.360.20.1.201 | Columnfa16e1et100SfpRxWaveLenLocal | read-only | current | 16E1-ET100(T/S) Series card, Rx Wave length of SFP. |
| 1.3.6.1.4.1.4756.20.360.20.1.202 | Columnfa16e1et100SfpLinkLenLocal | read-only | current | 16E1-ET100(T/S) Series card, Link length of SFP. |
| 1.3.6.1.4.1.4756.20.360.20.1.203 | Columnfa16e1et100SfpModelIDLocal | read-only | current | 16E1-ET100(T/S) Series card, model ID of SFP. |
| 1.3.6.1.4.1.4756.20.360.20.1.204 | Columnfa16e1et100SfpVersionLocal | read-only | current | 16E1-ET100(T/S) Series card, the version of SFP. |
| 1.3.6.1.4.1.4756.20.360.20.1.205 | Columnfa16e1et100SfpModelTypeLocal | read-only | current | 16E1-ET100(T/S) Series card, model type of SFP. |
| 1.3.6.1.4.1.4756.20.360.20.1.206 | Columnfa16e1et100DDInformationLocal | read-only | current | 16E1-ET100(T/S) Series card, D/D information of SFP Supported: 0:No, 1:Yes |
| 1.3.6.1.4.1.4756.20.360.20.1.207 | Columnfa16e1et100DDRxSensLocal | read-only | current | 16E1-ET100(T/S) Series card, Sensitivity of D/D information. |
| 1.3.6.1.4.1.4756.20.360.20.1.208 | Columnfa16e1et100DDTxPowerLocal | read-only | current | 16E1-ET100(T/S) Series card, Tx power of D/D information. |
| 1.3.6.1.4.1.4756.20.360.20.1.209 | Columnfa16e1et100DDRxPowerLocal | read-only | current | 16E1-ET100(T/S) Series card, Rx power of D/D information. |
| 1.3.6.1.4.1.4756.20.360.20.1.210 | Columnfa16e1et100DDTempLocal | read-only | current | 16E1-ET100(T/S) Series card, Temperature of D/D information in degree C. |
| 1.3.6.1.4.1.4756.20.360.20.1.211 | Columnfa16e1et100DDBiasLocal | read-only | current | 16E1-ET100(T/S) Series card, BIAS of D/D information. |
| 1.3.6.1.4.1.4756.20.360.20.1.212 | Columnfa16e1et100DDVoltageLocal | read-only | current | 16E1-ET100(T/S) Series card, Voltage of D/D information. |
| 1.3.6.1.4.1.4756.20.360.20.1.213 | Columnfa16e1et100ChannelDefectLocal | read-write | current | 16E1-ET100(T/S) Series card Channel Defect: 0:Disable 4:1E-4 6:1E-6 |
| 1.3.6.1.4.1.4756.20.360.20.1.214 | Columnfa16e1et100LoopDetectionLocal | read-write | current | 16E1-ET100(T/S) Series card Loop Detection: 0:Disable 1:Enable |
| 1.3.6.1.4.1.4756.20.360.20.1.215 | Columnfa16e1et100LoopCh1Local | read-only | current | 16E1-ET100(T/S) Series card E1 channel 1 Loop Check State: 0:No 1:Yes |
| 1.3.6.1.4.1.4756.20.360.20.1.216 | Columnfa16e1et100LoopCh2Local | read-only | current | 16E1-ET100(T/S) Series card E1 channel 2 Loop Check State: 0:No 1:Yes |
| 1.3.6.1.4.1.4756.20.360.20.1.217 | Columnfa16e1et100LoopCh3Local | read-only | current | 16E1-ET100(T/S) Series card E1 channel 3 Loop Check State: 0:No 1:Yes |
| 1.3.6.1.4.1.4756.20.360.20.1.218 | Columnfa16e1et100LoopCh4Local | read-only | current | 16E1-ET100(T/S) Series card E1 channel 4 Loop Check State: 0:No 1:Yes |
| 1.3.6.1.4.1.4756.20.360.20.1.219 | Columnfa16e1et100LoopCh5Local | read-only | current | 16E1-ET100(T/S) Series card E1 channel 5 Loop Check State: 0:No 1:Yes |
| 1.3.6.1.4.1.4756.20.360.20.1.220 | Columnfa16e1et100LoopCh6Local | read-only | current | 16E1-ET100(T/S) Series card E1 channel 6 Loop Check State: 0:No 1:Yes |
| 1.3.6.1.4.1.4756.20.360.20.1.221 | Columnfa16e1et100LoopCh7Local | read-only | current | 16E1-ET100(T/S) Series card E1 channel 7 Loop Check State: 0:No 1:Yes |
| 1.3.6.1.4.1.4756.20.360.20.1.222 | Columnfa16e1et100LoopCh8Local | read-only | current | 16E1-ET100(T/S) Series card E1 channel 8 Loop Check State: 0:No 1:Yes |
| 1.3.6.1.4.1.4756.20.360.20.1.223 | Columnfa16e1et100LoopCh9Local | read-only | current | 16E1-ET100(T/S) Series card E1 channel 9 Loop Check State: 0:No 1:Yes |
| 1.3.6.1.4.1.4756.20.360.20.1.224 | Columnfa16e1et100LoopCh10Local | read-only | current | 16E1-ET100(T/S) Series card E1 channel 10 Loop Check State: 0:No 1:Yes |
| 1.3.6.1.4.1.4756.20.360.20.1.225 | Columnfa16e1et100LoopCh11Local | read-only | current | 16E1-ET100(T/S) Series card E1 channel 11 Loop Check State: 0:No 1:Yes |
| 1.3.6.1.4.1.4756.20.360.20.1.226 | Columnfa16e1et100LoopCh12Local | read-only | current | 16E1-ET100(T/S) Series card E1 channel 12 Loop Check State: 0:No 1:Yes |
| 1.3.6.1.4.1.4756.20.360.20.1.227 | Columnfa16e1et100LoopCh13Local | read-only | current | 16E1-ET100(T/S) Series card E1 channel 13 Loop Check State: 0:No 1:Yes |
| 1.3.6.1.4.1.4756.20.360.20.1.228 | Columnfa16e1et100LoopCh14Local | read-only | current | 16E1-ET100(T/S) Series card E1 channel 14 Loop Check State: 0:No 1:Yes |
| 1.3.6.1.4.1.4756.20.360.20.1.229 | Columnfa16e1et100LoopCh15Local | read-only | current | 16E1-ET100(T/S) Series card E1 channel 15 Loop Check State: 0:No 1:Yes |
| 1.3.6.1.4.1.4756.20.360.20.1.230 | Columnfa16e1et100LoopCh16Local | read-only | current | 16E1-ET100(T/S) Series card E1 channel 16 Loop Check State: 0:No 1:Yes |
| 1.3.6.1.4.1.4756.20.360.20.1.231 | Columnfa16e1et100DefectCh1Local | read-only | current | 16E1-ET100(T/S) Series card E1 channel 1 Defect Status: 0:No 1:Yes |
| 1.3.6.1.4.1.4756.20.360.20.1.232 | Columnfa16e1et100DefectCh2Local | read-only | current | 16E1-ET100(T/S) Series card E1 channel 2 Defect Status: 0:No 1:Yes |
| 1.3.6.1.4.1.4756.20.360.20.1.233 | Columnfa16e1et100DefectCh3Local | read-only | current | 16E1-ET100(T/S) Series card E1 channel 3 Defect Status: 0:No 1:Yes |
| 1.3.6.1.4.1.4756.20.360.20.1.234 | Columnfa16e1et100DefectCh4Local | read-only | current | 16E1-ET100(T/S) Series card E1 channel 4 Defect Status: 0:No 1:Yes |
| 1.3.6.1.4.1.4756.20.360.20.1.235 | Columnfa16e1et100DefectCh5Local | read-only | current | 16E1-ET100(T/S) Series card E1 channel 5 Defect Status: 0:No 1:Yes |
| 1.3.6.1.4.1.4756.20.360.20.1.236 | Columnfa16e1et100DefectCh6Local | read-only | current | 16E1-ET100(T/S) Series card E1 channel 6 Defect Status: 0:No 1:Yes |
| 1.3.6.1.4.1.4756.20.360.20.1.237 | Columnfa16e1et100DefectCh7Local | read-only | current | 16E1-ET100(T/S) Series card E1 channel 7 Defect Status: 0:No 1:Yes |
| 1.3.6.1.4.1.4756.20.360.20.1.238 | Columnfa16e1et100DefectCh8Local | read-only | current | 16E1-ET100(T/S) Series card E1 channel 8 Defect Status: 0:No 1:Yes |
| 1.3.6.1.4.1.4756.20.360.20.1.239 | Columnfa16e1et100DefectCh9Local | read-only | current | 16E1-ET100(T/S) Series card E1 channel 9 Defect Status: 0:No 1:Yes |
| 1.3.6.1.4.1.4756.20.360.20.1.240 | Columnfa16e1et100DefectCh10Local | read-only | current | 16E1-ET100(T/S) Series card E1 channel 10 Defect Status: 0:No 1:Yes |
| 1.3.6.1.4.1.4756.20.360.20.1.241 | Columnfa16e1et100DefectCh11Local | read-only | current | 16E1-ET100(T/S) Series card E1 channel 11 Defect Status: 0:No 1:Yes |
| 1.3.6.1.4.1.4756.20.360.20.1.242 | Columnfa16e1et100DefectCh12Local | read-only | current | 16E1-ET100(T/S) Series card E1 channel 12 Defect Status: 0:No 1:Yes |
| 1.3.6.1.4.1.4756.20.360.20.1.243 | Columnfa16e1et100DefectCh13Local | read-only | current | 16E1-ET100(T/S) Series card E1 channel 13 Defect Status: 0:No 1:Yes |
| 1.3.6.1.4.1.4756.20.360.20.1.244 | Columnfa16e1et100DefectCh14Local | read-only | current | 16E1-ET100(T/S) Series card E1 channel 14 Defect Status: 0:No 1:Yes |
| 1.3.6.1.4.1.4756.20.360.20.1.245 | Columnfa16e1et100DefectCh15Local | read-only | current | 16E1-ET100(T/S) Series card E1 channel 15 Defect Status: 0:No 1:Yes |
| 1.3.6.1.4.1.4756.20.360.20.1.246 | Columnfa16e1et100DefectCh16Local | read-only | current | 16E1-ET100(T/S) Series card E1 channel 16 Defect Status: 0:No 1:Yes |
| 1.3.6.1.4.1.4756.20.360.20.1.247 | Columnfa16e1et100FxSignalLocal | read-only | current | 16E1-ET100(T/S) Series card Fiber signal detect(SD): 0:Fiber unplugged 1:Signal detected |
| 1.3.6.1.4.1.4756.20.360.20.1.248 | Columnfa16e1et100PortResetLocal | read-write | current | 16E1-ET100(T/S) Series card Port Reset: 0:Action 1:Off |
| 1.3.6.1.4.1.4756.20.360.20.1.249 | Columnfa16e1et100VLANModeLocal | read-write | current | 16E1-ET100(T/S) Series card VLAN mode: 0:MODE2 1:MODE1 |
| 1.3.6.1.4.1.4756.20.360.20.1.250 | Columnfa16e1et100ETagSelectEntryLocal | read-write | current | 16E1-ET100(T/S) Series card ETag select entry: |
| 1.3.6.1.4.1.4756.20.360.20.1.251 | Columnfa16e1et100ETagMethodLocal | read-write | current | 16E1-ET100(T/S) Series card ETag Method: 0: Intouch 1: Add Tag 2: Remove Tag |
| 1.3.6.1.4.1.4756.20.360.20.1.252 | Columnfa16e1et100VLANTableVID1Local | read-write | current | 16E1-ET100(T/S) Series card VLAN Table: VLAN ID1 |
| 1.3.6.1.4.1.4756.20.360.20.1.253 | Columnfa16e1et100VLANTableVID2Local | read-write | current | 16E1-ET100(T/S) Series card VLAN Table: VLAN ID2 |
| 1.3.6.1.4.1.4756.20.360.20.1.254 | Columnfa16e1et100VLANTableVID3Local | read-write | current | 16E1-ET100(T/S) Series card VLAN Table: VLAN ID3 |
| 1.3.6.1.4.1.4756.20.360.20.1.255 | Columnfa16e1et100VLANTableVID4Local | read-write | current | 16E1-ET100(T/S) Series card VLAN Table: VLAN ID4 |
| 1.3.6.1.4.1.4756.20.360.20.1.256 | Columnfa16e1et100VLANTableVID5Local | read-write | current | 16E1-ET100(T/S) Series card VLAN Table: VLAN ID5 |
| 1.3.6.1.4.1.4756.20.360.20.1.257 | Columnfa16e1et100VLANTableVID6Local | read-write | current | 16E1-ET100(T/S) Series card VLAN Table: VLAN ID6 |
| 1.3.6.1.4.1.4756.20.360.20.1.258 | Columnfa16e1et100VLANTableVID7Local | read-write | current | 16E1-ET100(T/S) Series card VLAN Table: VLAN ID7 |
| 1.3.6.1.4.1.4756.20.360.20.1.259 | Columnfa16e1et100VLANTableVID8Local | read-write | current | 16E1-ET100(T/S) Series card VLAN Table: VLAN ID8 |
| 1.3.6.1.4.1.4756.20.360.20.1.260 | Columnfa16e1et100VLANTableVID9Local | read-write | current | 16E1-ET100(T/S) Series card VLAN Table: VLAN ID9 |
| 1.3.6.1.4.1.4756.20.360.20.1.261 | Columnfa16e1et100VLANTableVID10Local | read-write | current | 16E1-ET100(T/S) Series card VLAN Table: VLAN ID10 |
| 1.3.6.1.4.1.4756.20.360.20.1.262 | Columnfa16e1et100VLANTableVID11Local | read-write | current | 16E1-ET100(T/S) Series card VLAN Table: VLAN ID11 |
| 1.3.6.1.4.1.4756.20.360.20.1.263 | Columnfa16e1et100VLANTableVID12Local | read-write | current | 16E1-ET100(T/S) Series card VLAN Table: VLAN ID12 |
| 1.3.6.1.4.1.4756.20.360.20.1.264 | Columnfa16e1et100VLANTableVID13Local | read-write | current | 16E1-ET100(T/S) Series card VLAN Table: VLAN ID13 |
| 1.3.6.1.4.1.4756.20.360.20.1.265 | Columnfa16e1et100VLANTableVID14Local | read-write | current | 16E1-ET100(T/S) Series card VLAN Table: VLAN ID14 |
| 1.3.6.1.4.1.4756.20.360.20.1.266 | Columnfa16e1et100VLANTableVID15Local | read-write | current | 16E1-ET100(T/S) Series card VLAN Table: VLAN ID15 |
| 1.3.6.1.4.1.4756.20.360.20.1.267 | Columnfa16e1et100VLANTableVID16Local | read-write | current | 16E1-ET100(T/S) Series card VLAN Table: VLAN ID16 |
| 1.3.6.1.4.1.4756.20.361 | Nodef16E1RemoteCards | |||
| 1.3.6.1.4.1.4756.20.361.20 | Tablef16E1RemoteTable | not-accessible | current | A list of local FRM220-16E1-ET100 series card entries. The number of entries is f16E1-No-L. |
| 1.3.6.1.4.1.4756.20.361.20.1 | Rowf16E1RemoteEntry | not-accessible | current | An entry containing management information applicable to a particular local FRM220-16E1 series card. |
| 1.3.6.1.4.1.4756.20.361.20.1.1 | Columnfa16e1et100ChassisIndexRemote | read-only | current | A unique value for each card. It starts from 0 to 9 contiguously. |
| 1.3.6.1.4.1.4756.20.361.20.1.2 | Columnfa16e1et100SlotIndexRemote | read-only | current | A unique value for each card. It starts from 1 to 20 contiguously. |
| 1.3.6.1.4.1.4756.20.361.20.1.3 | Columnfa16e1et100CardHWVerRemote | read-only | current | 16E1-ET100(T/S) Series card hardware version x.xxx |
| 1.3.6.1.4.1.4756.20.361.20.1.4 | Columnfa16e1et100CardFWVerRemote | read-only | current | 16E1-ET100(T/S) Series card firmware version x.xxx |
| 1.3.6.1.4.1.4756.20.361.20.1.5 | Columnfa16e1et100CardCPLDVerRemote | read-only | current | 16E1-ET100(T/S) Series card CPLD version x.xxx |
| 1.3.6.1.4.1.4756.20.361.20.1.6 | Columnfa16e1et100CardFPGAVerRemote | read-only | current | 16E1-ET100(T/S) Series card FPGA version x.xxx |
| 1.3.6.1.4.1.4756.20.361.20.1.7 | Columnfa16e1et100ModelRemote | read-only | current | Card Type: 0:16E1-ET100T 1:16E1-ET100S |
| 1.3.6.1.4.1.4756.20.361.20.1.8 | Columnfa16e1et100SystemStatusRemote | read-only | current | 16E1-ET100(T/S) Series card system status: 0:Normal 1:Alarm |
| 1.3.6.1.4.1.4756.20.361.20.1.9 | Columnfa16e1et100DeviceActiveRemote | read-only | current | 16E1-ET100(T/S) Series card active: 0:Disable 1:Enable |
| 1.3.6.1.4.1.4756.20.361.20.1.10 | Columnfa16e1et100SetToDefaultRemote | read-write | current | 16E1-ET100(T/S) Series card port set to default: 0:Off 1:Trigger |
| 1.3.6.1.4.1.4756.20.361.20.1.11 | Columnfa16e1et100E1Ch1SingalRemote | read-only | current | 16E1-ET100(T/S) Series card E1 channel 1 signal status: 0:Singal Loss 1:Normal |
| 1.3.6.1.4.1.4756.20.361.20.1.12 | Columnfa16e1et100E1Ch2SingalRemote | read-only | current | 16E1-ET100(T/S) Series card E1 channel 2 signal status: 0:Singal Loss 1:Normal |
| 1.3.6.1.4.1.4756.20.361.20.1.13 | Columnfa16e1et100E1Ch3SingalRemote | read-only | current | 16E1-ET100(T/S) Series card E1 channel 3 signal status: 0:Singal Loss 1:Normal |
| 1.3.6.1.4.1.4756.20.361.20.1.14 | Columnfa16e1et100E1Ch4SingalRemote | read-only | current | 16E1-ET100(T/S) Series card E1 channel 4 signal status: 0:Singal Loss 1:Normal |
| 1.3.6.1.4.1.4756.20.361.20.1.15 | Columnfa16e1et100E1Ch5SingalRemote | read-only | current | 16E1-ET100(T/S) Series card E1 channel 5 signal status: 0:Singal Loss 1:Normal |
| 1.3.6.1.4.1.4756.20.361.20.1.16 | Columnfa16e1et100E1Ch6SingalRemote | read-only | current | 16E1-ET100(T/S) Series card E1 channel 6 signal status: 0:Singal Loss 1:Normal |
| 1.3.6.1.4.1.4756.20.361.20.1.17 | Columnfa16e1et100E1Ch7SingalRemote | read-only | current | 16E1-ET100(T/S) Series card E1 channel 7 signal status: 0:Singal Loss 1:Normal |
| 1.3.6.1.4.1.4756.20.361.20.1.18 | Columnfa16e1et100E1Ch8SingalRemote | read-only | current | 16E1-ET100(T/S) Series card E1 channel 8 signal status: 0:Singal Loss 1:Normal |
| 1.3.6.1.4.1.4756.20.361.20.1.19 | Columnfa16e1et100E1Ch9SingalRemote | read-only | current | 16E1-ET100(T/S) Series card E1 channel 9 signal status: 0:Singal Loss 1:Normal |
| 1.3.6.1.4.1.4756.20.361.20.1.20 | Columnfa16e1et100E1Ch10SingalRemote | read-only | current | 16E1-ET100(T/S) Series card E1 channel 10 signal status: 0:Singal Loss 1:Normal |
| 1.3.6.1.4.1.4756.20.361.20.1.21 | Columnfa16e1et100E1Ch11SingalRemote | read-only | current | 16E1-ET100(T/S) Series card E1 channel 11 signal status: 0:Singal Loss 1:Normal |
| 1.3.6.1.4.1.4756.20.361.20.1.22 | Columnfa16e1et100E1Ch12SingalRemote | read-only | current | 16E1-ET100(T/S) Series card E1 channel 12 signal status: 0:Singal Loss 1:Normal |
| 1.3.6.1.4.1.4756.20.361.20.1.23 | Columnfa16e1et100E1Ch13SingalRemote | read-only | current | 16E1-ET100(T/S) Series card E1 channel 13 signal status: 0:Singal Loss 1:Normal |
| 1.3.6.1.4.1.4756.20.361.20.1.24 | Columnfa16e1et100E1Ch14SingalRemote | read-only | current | 16E1-ET100(T/S) Series card E1 channel 14 signal status: 0:Singal Loss 1:Normal |
| 1.3.6.1.4.1.4756.20.361.20.1.25 | Columnfa16e1et100E1Ch15SingalRemote | read-only | current | 16E1-ET100(T/S) Series card E1 channel 15 signal status: 0:Singal Loss 1:Normal |
| 1.3.6.1.4.1.4756.20.361.20.1.26 | Columnfa16e1et100E1Ch16SingalRemote | read-only | current | 16E1-ET100(T/S) Series card E1 channel 16 signal status: 0:Singal Loss 1:Normal |
| 1.3.6.1.4.1.4756.20.361.20.1.27 | Columnfa16e1et100E1Ch1SyncRemote | read-only | current | 16E1-ET100(T/S) Series card E1 channel 1 sync status: 0:Sync Loss 1:Sync |
| 1.3.6.1.4.1.4756.20.361.20.1.28 | Columnfa16e1et100E1Ch2SyncRemote | read-only | current | 16E1-ET100(T/S) Series card E1 channel 2 sync status: 0:Sync Loss 1:Sync |
| 1.3.6.1.4.1.4756.20.361.20.1.29 | Columnfa16e1et100E1Ch3SyncRemote | read-only | current | 16E1-ET100(T/S) Series card E1 channel 3 sync status: 0:Sync Loss 1:Sync |
| 1.3.6.1.4.1.4756.20.361.20.1.30 | Columnfa16e1et100E1Ch4SyncRemote | read-only | current | 16E1-ET100(T/S) Series card E1 channel 4 sync status: 0:Sync Loss 1:Sync |
| 1.3.6.1.4.1.4756.20.361.20.1.31 | Columnfa16e1et100E1Ch5SyncRemote | read-only | current | 16E1-ET100(T/S) Series card E1 channel 5 sync status: 0:Sync Loss 1:Sync |
| 1.3.6.1.4.1.4756.20.361.20.1.32 | Columnfa16e1et100E1Ch6SyncRemote | read-only | current | 16E1-ET100(T/S) Series card E1 channel 6 sync status: 0:Sync Loss 1:Sync |
| 1.3.6.1.4.1.4756.20.361.20.1.33 | Columnfa16e1et100E1Ch7SyncRemote | read-only | current | 16E1-ET100(T/S) Series card E1 channel 7 sync status: 0:Sync Loss 1:Sync |
| 1.3.6.1.4.1.4756.20.361.20.1.34 | Columnfa16e1et100E1Ch8SyncRemote | read-only | current | 16E1-ET100(T/S) Series card E1 channel 8 sync status: 0:Sync Loss 1:Sync |
| 1.3.6.1.4.1.4756.20.361.20.1.35 | Columnfa16e1et100E1Ch9SyncRemote | read-only | current | 16E1-ET100(T/S) Series card E1 channel 9 sync status: 0:Sync Loss 1:Sync |
| 1.3.6.1.4.1.4756.20.361.20.1.36 | Columnfa16e1et100E1Ch10SyncRemote | read-only | current | 16E1-ET100(T/S) Series card E1 channel 10 sync status: 0:Sync Loss 1:Sync |
| 1.3.6.1.4.1.4756.20.361.20.1.37 | Columnfa16e1et100E1Ch11SyncRemote | read-only | current | 16E1-ET100(T/S) Series card E1 channel 11 sync status: 0:Sync Loss 1:Sync |
| 1.3.6.1.4.1.4756.20.361.20.1.38 | Columnfa16e1et100E1Ch12SyncRemote | read-only | current | 16E1-ET100(T/S) Series card E1 channel 12 sync status: 0:Sync Loss 1:Sync |
| 1.3.6.1.4.1.4756.20.361.20.1.39 | Columnfa16e1et100E1Ch13SyncRemote | read-only | current | 16E1-ET100(T/S) Series card E1 channel 13 sync status: 0:Sync Loss 1:Sync |
| 1.3.6.1.4.1.4756.20.361.20.1.40 | Columnfa16e1et100E1Ch14SyncRemote | read-only | current | 16E1-ET100(T/S) Series card E1 channel 14 sync status: 0:Sync Loss 1:Sync |
| 1.3.6.1.4.1.4756.20.361.20.1.41 | Columnfa16e1et100E1Ch15SyncRemote | read-only | current | 16E1-ET100(T/S) Series card E1 channel 15 sync status: 0:Sync Loss 1:Sync |
| 1.3.6.1.4.1.4756.20.361.20.1.42 | Columnfa16e1et100E1Ch16SyncRemote | read-only | current | 16E1-ET100(T/S) Series card E1 channel 16 sync status: 0:Sync Loss 1:Sync |
| 1.3.6.1.4.1.4756.20.361.20.1.43 | Columnfa16e1et100E1Ch1RecvAISRemote | read-only | current | 16E1-ET100(T/S) Series card E1 channel 1 receive AIS status: 0:No 1:Yes |
| 1.3.6.1.4.1.4756.20.361.20.1.44 | Columnfa16e1et100E1Ch2RecvAISRemote | read-only | current | 16E1-ET100(T/S) Series card E1 channel 2 receive AIS status: 0:No 1:Yes |
| 1.3.6.1.4.1.4756.20.361.20.1.45 | Columnfa16e1et100E1Ch3RecvAISRemote | read-only | current | 16E1-ET100(T/S) Series card E1 channel 3 receive AIS status: 0:No 1:Yes |
| 1.3.6.1.4.1.4756.20.361.20.1.46 | Columnfa16e1et100E1Ch4RecvAISRemote | read-only | current | 16E1-ET100(T/S) Series card E1 channel 4 receive AIS status: 0:No 1:Yes |
| 1.3.6.1.4.1.4756.20.361.20.1.47 | Columnfa16e1et100E1Ch5RecvAISRemote | read-only | current | 16E1-ET100(T/S) Series card E1 channel 5 receive AIS status: 0:No 1:Yes |
| 1.3.6.1.4.1.4756.20.361.20.1.48 | Columnfa16e1et100E1Ch6RecvAISRemote | read-only | current | 16E1-ET100(T/S) Series card E1 channel 6 receive AIS status: 0:No 1:Yes |
| 1.3.6.1.4.1.4756.20.361.20.1.49 | Columnfa16e1et100E1Ch7RecvAISRemote | read-only | current | 16E1-ET100(T/S) Series card E1 channel 7 receive AIS status: 0:No 1:Yes |
| 1.3.6.1.4.1.4756.20.361.20.1.50 | Columnfa16e1et100E1Ch8RecvAISRemote | read-only | current | 16E1-ET100(T/S) Series card E1 channel 8 receive AIS status: 0:No 1:Yes |
| 1.3.6.1.4.1.4756.20.361.20.1.51 | Columnfa16e1et100E1Ch9RecvAISRemote | read-only | current | 16E1-ET100(T/S) Series card E1 channel 9 receive AIS status: 0:No 1:Yes |
| 1.3.6.1.4.1.4756.20.361.20.1.52 | Columnfa16e1et100E1Ch10RecvAISRemote | read-only | current | 16E1-ET100(T/S) Series card E1 channel 10 receive AIS status: 0:No 1:Yes |
| 1.3.6.1.4.1.4756.20.361.20.1.53 | Columnfa16e1et100E1Ch11RecvAISRemote | read-only | current | 16E1-ET100(T/S) Series card E1 channel 11 receive AIS status: 0:No 1:Yes |
| 1.3.6.1.4.1.4756.20.361.20.1.54 | Columnfa16e1et100E1Ch12RecvAISRemote | read-only | current | 16E1-ET100(T/S) Series card E1 channel 12 receive AIS status: 0:No 1:Yes |
| 1.3.6.1.4.1.4756.20.361.20.1.55 | Columnfa16e1et100E1Ch13RecvAISRemote | read-only | current | 16E1-ET100(T/S) Series card E1 channel 13 receive AIS status: 0:No 1:Yes |
| 1.3.6.1.4.1.4756.20.361.20.1.56 | Columnfa16e1et100E1Ch14RecvAISRemote | read-only | current | 16E1-ET100(T/S) Series card E1 channel 14 receive AIS status: 0:No 1:Yes |
| 1.3.6.1.4.1.4756.20.361.20.1.57 | Columnfa16e1et100E1Ch15RecvAISRemote | read-only | current | 16E1-ET100(T/S) Series card E1 channel 15 receive AIS status: 0:No 1:Yes |
| 1.3.6.1.4.1.4756.20.361.20.1.58 | Columnfa16e1et100E1Ch16RecvAISRemote | read-only | current | 16E1-ET100(T/S) Series card E1 channel 16 receive AIS status: 0:No 1:Yes |
| 1.3.6.1.4.1.4756.20.361.20.1.59 | Columnfa16e1et100E1Ch1ConnTypeRemote | read-only | current | 16E1-ET100(T/S) Series card E1 channel 1 connector type: 0:RJ-48C 1:BNC |
| 1.3.6.1.4.1.4756.20.361.20.1.60 | Columnfa16e1et100E1Ch2ConnTypeRemote | read-only | current | 16E1-ET100(T/S) Series card E1 channel 2 connector type: 0:RJ-48C 1:BNC |
| 1.3.6.1.4.1.4756.20.361.20.1.61 | Columnfa16e1et100E1Ch3ConnTypeRemote | read-only | current | 16E1-ET100(T/S) Series card E1 channel 3 connector type: 0:RJ-48C 1:BNC |
| 1.3.6.1.4.1.4756.20.361.20.1.62 | Columnfa16e1et100E1Ch4ConnTypeRemote | read-only | current | 16E1-ET100(T/S) Series card E1 channel 4 connector type: 0:RJ-48C 1:BNC |
| 1.3.6.1.4.1.4756.20.361.20.1.63 | Columnfa16e1et100E1Ch5ConnTypeRemote | read-only | current | 16E1-ET100(T/S) Series card E1 channel 5 connector type: 0:RJ-48C 1:BNC |
| 1.3.6.1.4.1.4756.20.361.20.1.64 | Columnfa16e1et100E1Ch6ConnTypeRemote | read-only | current | 16E1-ET100(T/S) Series card E1 channel 6 connector type: 0:RJ-48C 1:BNC |
| 1.3.6.1.4.1.4756.20.361.20.1.65 | Columnfa16e1et100E1Ch7ConnTypeRemote | read-only | current | 16E1-ET100(T/S) Series card E1 channel 7 connector type: 0:RJ-48C 1:BNC |
| 1.3.6.1.4.1.4756.20.361.20.1.66 | Columnfa16e1et100E1Ch8ConnTypeRemote | read-only | current | 16E1-ET100(T/S) Series card E1 channel 8 connector type: 0:RJ-48C 1:BNC |
| 1.3.6.1.4.1.4756.20.361.20.1.67 | Columnfa16e1et100E1Ch9ConnTypeRemote | read-only | current | 16E1-ET100(T/S) Series card E1 channel 9 connector type: 0:RJ-48C 1:BNC |
| 1.3.6.1.4.1.4756.20.361.20.1.68 | Columnfa16e1et100E1Ch10ConnTypeRemote | read-only | current | 16E1-ET100(T/S) Series card E1 channel 10 connector type: 0:RJ-48C 1:BNC |
| 1.3.6.1.4.1.4756.20.361.20.1.69 | Columnfa16e1et100E1Ch11ConnTypeRemote | read-only | current | 16E1-ET100(T/S) Series card E1 channel 11 connector type: 0:RJ-48C 1:BNC |
| 1.3.6.1.4.1.4756.20.361.20.1.70 | Columnfa16e1et100E1Ch12ConnTypeRemote | read-only | current | 16E1-ET100(T/S) Series card E1 channel 12 connector type: 0:RJ-48C 1:BNC |
| 1.3.6.1.4.1.4756.20.361.20.1.71 | Columnfa16e1et100E1Ch13ConnTypeRemote | read-only | current | 16E1-ET100(T/S) Series card E1 channel 13 connector type: 0:RJ-48C 1:BNC |
| 1.3.6.1.4.1.4756.20.361.20.1.72 | Columnfa16e1et100E1Ch14ConnTypeRemote | read-only | current | 16E1-ET100(T/S) Series card E1 channel 14 connector type: 0:RJ-48C 1:BNC |
| 1.3.6.1.4.1.4756.20.361.20.1.73 | Columnfa16e1et100E1Ch15ConnTypeRemote | read-only | current | 16E1-ET100(T/S) Series card E1 channel 15 connector type: 0:RJ-48C 1:BNC |
| 1.3.6.1.4.1.4756.20.361.20.1.74 | Columnfa16e1et100E1Ch16ConnTypeRemote | read-only | current | 16E1-ET100(T/S) Series card E1 channel 16 connector type: 0:RJ-48C 1:BNC |
| 1.3.6.1.4.1.4756.20.361.20.1.75 | Columnfa16e1et100E1Ch1RAIRemote | read-only | current | 16E1-ET100(T/S) Series card E1 channel 1 RAI status: 0:No 1:Yes |
| 1.3.6.1.4.1.4756.20.361.20.1.76 | Columnfa16e1et100E1Ch2RAIRemote | read-only | current | 16E1-ET100(T/S) Series card E1 channel 2 RAI status: 0:No 1:Yes |
| 1.3.6.1.4.1.4756.20.361.20.1.77 | Columnfa16e1et100E1Ch3RAIRemote | read-only | current | 16E1-ET100(T/S) Series card E1 channel 3 RAI status: 0:No 1:Yes |
| 1.3.6.1.4.1.4756.20.361.20.1.78 | Columnfa16e1et100E1Ch4RAIRemote | read-only | current | 16E1-ET100(T/S) Series card E1 channel 4 RAI status: 0:No 1:Yes |
| 1.3.6.1.4.1.4756.20.361.20.1.79 | Columnfa16e1et100E1Ch5RAIRemote | read-only | current | 16E1-ET100(T/S) Series card E1 channel 5 RAI status: 0:No 1:Yes |
| 1.3.6.1.4.1.4756.20.361.20.1.80 | Columnfa16e1et100E1Ch6RAIRemote | read-only | current | 16E1-ET100(T/S) Series card E1 channel 6 RAI status: 0:No 1:Yes |
| 1.3.6.1.4.1.4756.20.361.20.1.81 | Columnfa16e1et100E1Ch7RAIRemote | read-only | current | 16E1-ET100(T/S) Series card E1 channel 7 RAI status: 0:No 1:Yes |
| 1.3.6.1.4.1.4756.20.361.20.1.82 | Columnfa16e1et100E1Ch8RAIRemote | read-only | current | 16E1-ET100(T/S) Series card E1 channel 8 RAI status: 0:No 1:Yes |
| 1.3.6.1.4.1.4756.20.361.20.1.83 | Columnfa16e1et100E1Ch9RAIRemote | read-only | current | 16E1-ET100(T/S) Series card E1 channel 9 RAI status: 0:No 1:Yes |
| 1.3.6.1.4.1.4756.20.361.20.1.84 | Columnfa16e1et100E1Ch10RAIRemote | read-only | current | 16E1-ET100(T/S) Series card E1 channel 10 RAI status: 0:No 1:Yes |
| 1.3.6.1.4.1.4756.20.361.20.1.85 | Columnfa16e1et100E1Ch11RAIRemote | read-only | current | 16E1-ET100(T/S) Series card E1 channel 11 RAI status: 0:No 1:Yes |
| 1.3.6.1.4.1.4756.20.361.20.1.86 | Columnfa16e1et100E1Ch12RAIRemote | read-only | current | 16E1-ET100(T/S) Series card E1 channel 12 RAI status: 0:No 1:Yes |
| 1.3.6.1.4.1.4756.20.361.20.1.87 | Columnfa16e1et100E1Ch13RAIRemote | read-only | current | 16E1-ET100(T/S) Series card E1 channel 13 RAI status: 0:No 1:Yes |
| 1.3.6.1.4.1.4756.20.361.20.1.88 | Columnfa16e1et100E1Ch14RAIRemote | read-only | current | 16E1-ET100(T/S) Series card E1 channel 14 RAI status: 0:No 1:Yes |
| 1.3.6.1.4.1.4756.20.361.20.1.89 | Columnfa16e1et100E1Ch15RAIRemote | read-only | current | 16E1-ET100(T/S) Series card E1 channel 15 RAI status: 0:No 1:Yes |
| 1.3.6.1.4.1.4756.20.361.20.1.90 | Columnfa16e1et100E1Ch16RAIRemote | read-only | current | 16E1-ET100(T/S) Series card E1 channel 16 RAI status: 0:No 1:Yes |
| 1.3.6.1.4.1.4756.20.361.20.1.91 | Columnfa16e1et100E1Ch1LOMFRemote | read-only | current | 16E1-ET100(T/S) Series card E1 channel 1 LOMF status: 0:No 1:Yes |
| 1.3.6.1.4.1.4756.20.361.20.1.92 | Columnfa16e1et100E1Ch2LOMFRemote | read-only | current | 16E1-ET100(T/S) Series card E1 channel 2 LOMF status: 0:No 1:Yes |
| 1.3.6.1.4.1.4756.20.361.20.1.93 | Columnfa16e1et100E1Ch3LOMFRemote | read-only | current | 16E1-ET100(T/S) Series card E1 channel 3 LOMF status: 0:No 1:Yes |
| 1.3.6.1.4.1.4756.20.361.20.1.94 | Columnfa16e1et100E1Ch4LOMFRemote | read-only | current | 16E1-ET100(T/S) Series card E1 channel 4 LOMF status: 0:No 1:Yes |
| 1.3.6.1.4.1.4756.20.361.20.1.95 | Columnfa16e1et100E1Ch5LOMFRemote | read-only | current | 16E1-ET100(T/S) Series card E1 channel 5 LOMF status: 0:No 1:Yes |
| 1.3.6.1.4.1.4756.20.361.20.1.96 | Columnfa16e1et100E1Ch6LOMFRemote | read-only | current | 16E1-ET100(T/S) Series card E1 channel 6 LOMF status: 0:No 1:Yes |
| 1.3.6.1.4.1.4756.20.361.20.1.97 | Columnfa16e1et100E1Ch7LOMFRemote | read-only | current | 16E1-ET100(T/S) Series card E1 channel 7 LOMF status: 0:No 1:Yes |
| 1.3.6.1.4.1.4756.20.361.20.1.98 | Columnfa16e1et100E1Ch8LOMFRemote | read-only | current | 16E1-ET100(T/S) Series card E1 channel 8 LOMF status: 0:No 1:Yes |
| 1.3.6.1.4.1.4756.20.361.20.1.99 | Columnfa16e1et100E1Ch9LOMFRemote | read-only | current | 16E1-ET100(T/S) Series card E1 channel 9 LOMF status: 0:No 1:Yes |
| 1.3.6.1.4.1.4756.20.361.20.1.100 | Columnfa16e1et100E1Ch10LOMFRemote | read-only | current | 16E1-ET100(T/S) Series card E1 channel 10 LOMF status: 0:No 1:Yes |
| 1.3.6.1.4.1.4756.20.361.20.1.101 | Columnfa16e1et100E1Ch11LOMFRemote | read-only | current | 16E1-ET100(T/S) Series card E1 channel 11 LOMF status: 0:No 1:Yes |
| 1.3.6.1.4.1.4756.20.361.20.1.102 | Columnfa16e1et100E1Ch12LOMFRemote | read-only | current | 16E1-ET100(T/S) Series card E1 channel 12 LOMF status: 0:No 1:Yes |
| 1.3.6.1.4.1.4756.20.361.20.1.103 | Columnfa16e1et100E1Ch13LOMFRemote | read-only | current | 16E1-ET100(T/S) Series card E1 channel 13 LOMF status: 0:No 1:Yes |
| 1.3.6.1.4.1.4756.20.361.20.1.104 | Columnfa16e1et100E1Ch14LOMFRemote | read-only | current | 16E1-ET100(T/S) Series card E1 channel 14 LOMF status: 0:No 1:Yes |
| 1.3.6.1.4.1.4756.20.361.20.1.105 | Columnfa16e1et100E1Ch15LOMFRemote | read-only | current | 16E1-ET100(T/S) Series card E1 channel 15 LOMF status: 0:No 1:Yes |
| 1.3.6.1.4.1.4756.20.361.20.1.106 | Columnfa16e1et100E1Ch16LOMFRemote | read-only | current | 16E1-ET100(T/S) Series card E1 channel 16 LOMF status: 0:No 1:Yes |
| 1.3.6.1.4.1.4756.20.361.20.1.107 | Columnfa16e1et100E1Ch1ActiveRemote | read-only | current | 16E1-ET100(T/S) Series card E1 channel 1 active status: 0:Inactive 1:Active |
| 1.3.6.1.4.1.4756.20.361.20.1.108 | Columnfa16e1et100E1Ch2ActiveRemote | read-only | current | 16E1-ET100(T/S) Series card E1 channel 2 active status: 0:Inactive 1:Active |
| 1.3.6.1.4.1.4756.20.361.20.1.109 | Columnfa16e1et100E1Ch3ActiveRemote | read-only | current | 16E1-ET100(T/S) Series card E1 channel 3 active status: 0:Inactive 1:Active |
| 1.3.6.1.4.1.4756.20.361.20.1.110 | Columnfa16e1et100E1Ch4ActiveRemote | read-only | current | 16E1-ET100(T/S) Series card E1 channel 4 active status: 0:Inactive 1:Active |
| 1.3.6.1.4.1.4756.20.361.20.1.111 | Columnfa16e1et100E1Ch5ActiveRemote | read-only | current | 16E1-ET100(T/S) Series card E1 channel 5 active status: 0:Inactive 1:Active |
| 1.3.6.1.4.1.4756.20.361.20.1.112 | Columnfa16e1et100E1Ch6ActiveRemote | read-only | current | 16E1-ET100(T/S) Series card E1 channel 6 active status: 0:Inactive 1:Active |
| 1.3.6.1.4.1.4756.20.361.20.1.113 | Columnfa16e1et100E1Ch7ActiveRemote | read-only | current | 16E1-ET100(T/S) Series card E1 channel 7 active status: 0:Inactive 1:Active |
| 1.3.6.1.4.1.4756.20.361.20.1.114 | Columnfa16e1et100E1Ch8ActiveRemote | read-only | current | 16E1-ET100(T/S) Series card E1 channel 8 active status: 0:Inactive 1:Active |
| 1.3.6.1.4.1.4756.20.361.20.1.115 | Columnfa16e1et100E1Ch9ActiveRemote | read-only | current | 16E1-ET100(T/S) Series card E1 channel 9 active status: 0:Inactive 1:Active |
| 1.3.6.1.4.1.4756.20.361.20.1.116 | Columnfa16e1et100E1Ch10ActiveRemote | read-only | current | 16E1-ET100(T/S) Series card E1 channel 10 active status: 0:Inactive 1:Active |
| 1.3.6.1.4.1.4756.20.361.20.1.117 | Columnfa16e1et100E1Ch11ActiveRemote | read-only | current | 16E1-ET100(T/S) Series card E1 channel 11 active status: 0:Inactive 1:Active |
| 1.3.6.1.4.1.4756.20.361.20.1.118 | Columnfa16e1et100E1Ch12ActiveRemote | read-only | current | 16E1-ET100(T/S) Series card E1 channel 12 active status: 0:Inactive 1:Active |
| 1.3.6.1.4.1.4756.20.361.20.1.119 | Columnfa16e1et100E1Ch13ActiveRemote | read-only | current | 16E1-ET100(T/S) Series card E1 channel 13 active status: 0:Inactive 1:Active |
| 1.3.6.1.4.1.4756.20.361.20.1.120 | Columnfa16e1et100E1Ch14ActiveRemote | read-only | current | 16E1-ET100(T/S) Series card E1 channel 14 active status: 0:Inactive 1:Active |
| 1.3.6.1.4.1.4756.20.361.20.1.121 | Columnfa16e1et100E1Ch15ActiveRemote | read-only | current | 16E1-ET100(T/S) Series card E1 channel 15 active status: 0:Inactive 1:Active |
| 1.3.6.1.4.1.4756.20.361.20.1.122 | Columnfa16e1et100E1Ch16ActiveRemote | read-only | current | 16E1-ET100(T/S) Series card E1 channel 16 active status: 0:Inactive 1:Active |
| 1.3.6.1.4.1.4756.20.361.20.1.123 | Columnfa16e1et100E1Ch1LoopBackRemote | read-write | current | 16E1-ET100(T/S) Series card port E1 channel 1 loop back: 0:Off 2:RLB (Max used 15 channels) |
| 1.3.6.1.4.1.4756.20.361.20.1.124 | Columnfa16e1et100E1Ch2LoopBackRemote | read-write | current | 16E1-ET100(T/S) Series card port E1 channel 2 loop back: 0:Off 2:RLB (Max used 15 channels) |
| 1.3.6.1.4.1.4756.20.361.20.1.125 | Columnfa16e1et100E1Ch3LoopBackRemote | read-write | current | 16E1-ET100(T/S) Series card port E1 channel 3 loop back: 0:Off 2:RLB (Max used 15 channels) |
| 1.3.6.1.4.1.4756.20.361.20.1.126 | Columnfa16e1et100E1Ch4LoopBackRemote | read-write | current | 16E1-ET100(T/S) Series card port E1 channel 4 loop back: 0:Off 2:RLB (Max used 15 channels) |
| 1.3.6.1.4.1.4756.20.361.20.1.127 | Columnfa16e1et100E1Ch5LoopBackRemote | read-write | current | 16E1-ET100(T/S) Series card port E1 channel 5 loop back: 0:Off 2:RLB (Max used 15 channels) |
| 1.3.6.1.4.1.4756.20.361.20.1.128 | Columnfa16e1et100E1Ch6LoopBackRemote | read-write | current | 16E1-ET100(T/S) Series card port E1 channel 6 loop back: 0:Off 2:RLB (Max used 15 channels) |
| 1.3.6.1.4.1.4756.20.361.20.1.129 | Columnfa16e1et100E1Ch7LoopBackRemote | read-write | current | 16E1-ET100(T/S) Series card port E1 channel 7 loop back: 0:Off 2:RLB (Max used 15 channels) |
| 1.3.6.1.4.1.4756.20.361.20.1.130 | Columnfa16e1et100E1Ch8LoopBackRemote | read-write | current | 16E1-ET100(T/S) Series card port E1 channel 8 loop back: 0:Off 2:RLB (Max used 15 channels) |
| 1.3.6.1.4.1.4756.20.361.20.1.131 | Columnfa16e1et100E1Ch9LoopBackRemote | read-write | current | 16E1-ET100(T/S) Series card port E1 channel 9 loop back: 0:Off 2:RLB (Max used 15 channels) |
| 1.3.6.1.4.1.4756.20.361.20.1.132 | Columnfa16e1et100E1Ch10LoopBackRemote | read-write | current | 16E1-ET100(T/S) Series card port E1 channel 10 loop back: 0:Off 2:RLB (Max used 15 channels) |
| 1.3.6.1.4.1.4756.20.361.20.1.133 | Columnfa16e1et100E1Ch11LoopBackRemote | read-write | current | 16E1-ET100(T/S) Series card port E1 channel 11 loop back: 0:Off 2:RLB (Max used 15 channels) |
| 1.3.6.1.4.1.4756.20.361.20.1.134 | Columnfa16e1et100E1Ch12LoopBackRemote | read-write | current | 16E1-ET100(T/S) Series card port E1 channel 12 loop back: 0:Off 2:RLB (Max used 15 channels) |
| 1.3.6.1.4.1.4756.20.361.20.1.135 | Columnfa16e1et100E1Ch13LoopBackRemote | read-write | current | 16E1-ET100(T/S) Series card port E1 channel 13 loop back: 0:Off 2:RLB (Max used 15 channels) |
| 1.3.6.1.4.1.4756.20.361.20.1.136 | Columnfa16e1et100E1Ch14LoopBackRemote | read-write | current | 16E1-ET100(T/S) Series card port E1 channel 14 loop back: 0:Off 2:RLB (Max used 15 channels) |
| 1.3.6.1.4.1.4756.20.361.20.1.137 | Columnfa16e1et100E1Ch15LoopBackRemote | read-write | current | 16E1-ET100(T/S) Series card port E1 channel 15 loop back: 0:Off 2:RLB (Max used 15 channels) |
| 1.3.6.1.4.1.4756.20.361.20.1.138 | Columnfa16e1et100E1Ch16LoopBackRemote | read-write | current | 16E1-ET100(T/S) Series card port E1 channel 16 loop back: 0:Off 2:RLB (Max used 15 channels) |
| 1.3.6.1.4.1.4756.20.361.20.1.139 | Columnfa16e1et100FxLinkRemote | read-only | current | 16E1-ET100S Series card Fiber siganl detect status: 0:Down or Fiber unplugged 1:Up or Singal detected |
| 1.3.6.1.4.1.4756.20.361.20.1.140 | Columnfa16e1et100FxLaserRemote | read-only | current | 16E1-ET100S Series card laser status: 0:Normal 1:Error |
| 1.3.6.1.4.1.4756.20.361.20.1.141 | Columnfa16e1et100FxActiveRemote | read-write | current | 16E1-ET100S Series card Fiber active: 0:Inactive 1:Active |
| 1.3.6.1.4.1.4756.20.361.20.1.142 | Columnfa16e1et100FxLaserOutputRemote | read-write | current | 16E1-ET100S Series card laser output: 0:disable 1:Enable |
| 1.3.6.1.4.1.4756.20.361.20.1.143 | Columnfa16e1et100FxOpModeRemote | read-write | current | 16E1-ET100S Series card operation mode: 0:Switch 1:Convert |
| 1.3.6.1.4.1.4756.20.361.20.1.144 | Columnfa16e1et100UtpLinkRemote | read-only | current | 16E1-ET100T Series card UTP link status: 0:Link Down 1:Link Up |
| 1.3.6.1.4.1.4756.20.361.20.1.145 | Columnfa16e1et100UtpStatusRemote | read-only | current | 16E1-ET100T Series card UTP link mode status: 0:None, Maybe link down 1:Link at 10Mbps, Half duplex 2:Link at 10Mbps, Full duplex 3:Link at 100Mbps, Half duple… |
| 1.3.6.1.4.1.4756.20.361.20.1.146 | Columnfa16e1et100UtpFlowCtrlStsRemote | read-only | current | 16E1-ET100T Series card UTP flow control status: 0:Disable 1:Enable |
| 1.3.6.1.4.1.4756.20.361.20.1.147 | Columnfa16e1et100UtpModeRemote | read-write | current | 16E1-ET100T Series card UTP mode: 0:Disable 1:Enable and autoNegotiation 3:Enable and force to 10Mbps, Half duplex 4:Enable and force to 10Mbps, Full duplex 5:… |
| 1.3.6.1.4.1.4756.20.361.20.1.148 | Columnfa16e1et100UtpFlowCtrlRemote | read-write | current | 16E1-ET100T Series card UTP flow control: 0:Disable 1:Enable |
| 1.3.6.1.4.1.4756.20.361.20.1.149 | Columnfa16e1et100SpeedLimitRemote | read-write | current | 16E1-ET100(T/S) Series card speed limit: Limited = this value * 32Kbps, this value is restricted to 0 ~ 3125, 0 to disable |
| 1.3.6.1.4.1.4756.20.361.20.1.150 | Columnfa16e1et100VlanAwareRemote | read-write | current | 16E1-ET100(T/S) Series card 802.1q VLAN tag aware: 0:Disable 1:Enable |
| 1.3.6.1.4.1.4756.20.361.20.1.151 | Columnfa16e1et100VlanIDRemote | read-write | current | 16E1-ET100(T/S) Series card VLAN ID: The ID is restricted to 1 ~ 4094 |
| 1.3.6.1.4.1.4756.20.361.20.1.152 | Columnfa16e1et100RemoteDeviceRemote | read-only | current | FRM220A-16E1 Series card remote device status: 0:Link Down 1:Link Up |
| 1.3.6.1.4.1.4756.20.361.20.1.153 | Columnfa16e1et100RemotePowerRemote | read-only | current | 16E1-ET100(T/S) Series card remote device power status: 0:Normal 1:Power off |
| 1.3.6.1.4.1.4756.20.361.20.1.154 | Columnfa16e1et100TimingSourceRemote | read-write | current | 16E1-ET100(T/S) Series card clock: 0:Internal oscillatro 1:Recovery from E1 channel 1 2:Recovery from E1 channel 2 3:Recovery from E1 channel 3 4:Recovery from… |
| 1.3.6.1.4.1.4756.20.361.20.1.155 | Columnfa16e1et100FCSofGFPRemote | read-write | current | 16E1-ET100(T/S) Series card FCS of GFP: 0:Disable 1:Enable |
| 1.3.6.1.4.1.4756.20.361.20.1.156 | Columnfa16e1et100AutoChAdjustRemote | read-write | current | 16E1-ET100(T/S) Series card auto channel Bdjust: 0:Disable 1:Enable |
| 1.3.6.1.4.1.4756.20.361.20.1.157 | Columnfa16e1et100PayloadScrambleRemote | read-write | current | 16E1-ET100(T/S) Series card payload scramble: 0:Disable 1:Enable |
| 1.3.6.1.4.1.4756.20.361.20.1.158 | Columnfa16e1et100FailoverRemote | read-write | current | 16E1-ET100(T/S) Series card failover: 0:Disable 1:Enable |
| 1.3.6.1.4.1.4756.20.361.20.1.159 | Columnfa16e1et100LOMRemote | read-only | current | 16E1-ET100(T/S) Series card LOM status: 0:No 1:Yes |
| 1.3.6.1.4.1.4756.20.361.20.1.160 | Columnfa16e1et100SQMRemote | read-only | current | 16E1-ET100(T/S) Series card SQM status: 0:No 1:Yes |
| 1.3.6.1.4.1.4756.20.361.20.1.161 | Columnfa16e1et100CRCRemote | read-only | current | 16E1-ET100(T/S) Series card CRC status: 0:No 1:Yes |
| 1.3.6.1.4.1.4756.20.361.20.1.162 | Columnfa16e1et100LOARemote | read-only | current | 16E1-ET100(T/S) Series card LOA status: 0:No 1:Yes |
| 1.3.6.1.4.1.4756.20.361.20.1.163 | Columnfa16e1et100LFDRemote | read-only | current | 16E1-ET100(T/S) Series card LFD status: 0:No 1:Yes |
| 1.3.6.1.4.1.4756.20.361.20.1.164 | Columnfa16e1et100DDTORemote | read-only | current | 16E1-ET100(T/S) Series card DDTO status: 0:No 1:Yes |
| 1.3.6.1.4.1.4756.20.361.20.1.165 | Columnfa16e1et100VcatMember1Remote | read-write | current | 16E1-ET100(T/S) Series card VACT member 1: 0:Disable 1:Enable |
| 1.3.6.1.4.1.4756.20.361.20.1.166 | Columnfa16e1et100VcatMember2Remote | read-write | current | 16E1-ET100(T/S) Series card VACT member 2: 0:Disable 1:Enable |
| 1.3.6.1.4.1.4756.20.361.20.1.167 | Columnfa16e1et100VcatMember3Remote | read-write | current | 16E1-ET100(T/S) Series card VACT member 3: 0:Disable 1:Enable |
| 1.3.6.1.4.1.4756.20.361.20.1.168 | Columnfa16e1et100VcatMember4Remote | read-write | current | 16E1-ET100(T/S) Series card VACT member 4: 0:Disable 1:Enable |
| 1.3.6.1.4.1.4756.20.361.20.1.169 | Columnfa16e1et100VcatMember5Remote | read-write | current | 16E1-ET100(T/S) Series card VACT member 5: 0:Disable 1:Enable |
| 1.3.6.1.4.1.4756.20.361.20.1.170 | Columnfa16e1et100VcatMember6Remote | read-write | current | 16E1-ET100(T/S) Series card VACT member 6: 0:Disable 1:Enable |
| 1.3.6.1.4.1.4756.20.361.20.1.171 | Columnfa16e1et100VcatMember7Remote | read-write | current | 16E1-ET100(T/S) Series card VACT member 7: 0:Disable 1:Enable |
| 1.3.6.1.4.1.4756.20.361.20.1.172 | Columnfa16e1et100VcatMember8Remote | read-write | current | 16E1-ET100(T/S) Series card VACT member 8: 0:Disable 1:Enable |
| 1.3.6.1.4.1.4756.20.361.20.1.173 | Columnfa16e1et100VcatMember9Remote | read-write | current | 16E1-ET100(T/S) Series card VACT member 9: 0:Disable 1:Enable |
| 1.3.6.1.4.1.4756.20.361.20.1.174 | Columnfa16e1et100VcatMember10Remote | read-write | current | 16E1-ET100(T/S) Series card VACT member 10: 0:Disable 1:Enable |
| 1.3.6.1.4.1.4756.20.361.20.1.175 | Columnfa16e1et100VcatMember11Remote | read-write | current | 16E1-ET100(T/S) Series card VACT member 11: 0:Disable 1:Enable |
| 1.3.6.1.4.1.4756.20.361.20.1.176 | Columnfa16e1et100VcatMember12Remote | read-write | current | 16E1-ET100(T/S) Series card VACT member 12: 0:Disable 1:Enable |
| 1.3.6.1.4.1.4756.20.361.20.1.177 | Columnfa16e1et100VcatMember13Remote | read-write | current | 16E1-ET100(T/S) Series card VACT member 13: 0:Disable 1:Enable |
| 1.3.6.1.4.1.4756.20.361.20.1.178 | Columnfa16e1et100VcatMember14Remote | read-write | current | 16E1-ET100(T/S) Series card VACT member 14: 0:Disable 1:Enable |
| 1.3.6.1.4.1.4756.20.361.20.1.179 | Columnfa16e1et100VcatMember15Remote | read-write | current | 16E1-ET100(T/S) Series card VACT member 15: 0:Disable 1:Enable |
| 1.3.6.1.4.1.4756.20.361.20.1.180 | Columnfa16e1et100VcatMember16Remote | read-write | current | 16E1-ET100(T/S) Series card VACT member 16: 0:Disable 1:Enable |
| 1.3.6.1.4.1.4756.20.361.20.1.181 | Columnfa16e1et100SnmpChannel1Remote | read-write | current | 16E1-ET100(T/S) Series card SNMP channel 0: 0:No use 1:Use |
| 1.3.6.1.4.1.4756.20.361.20.1.182 | Columnfa16e1et100SnmpChannel2Remote | read-write | current | 16E1-ET100(T/S) Series card SNMP channel 1: 0:No use 1:Use |
| 1.3.6.1.4.1.4756.20.361.20.1.183 | Columnfa16e1et100SnmpChannel3Remote | read-write | current | 16E1-ET100(T/S) Series card SNMP channel 3: 0:No use 1:Use |
| 1.3.6.1.4.1.4756.20.361.20.1.184 | Columnfa16e1et100SnmpChannel4Remote | read-write | current | 16E1-ET100(T/S) Series card SNMP channel 4: 0:No use 1:Use |
| 1.3.6.1.4.1.4756.20.361.20.1.185 | Columnfa16e1et100ErrSecRemote | read-only | current | 16E1-ET100(T/S) Series card, errored seconds of BERT result. |
| 1.3.6.1.4.1.4756.20.361.20.1.186 | Columnfa16e1et100ErrFreeSecRemote | read-only | current | 16E1-ET100(T/S) Series card, errored free seconds of BERT result. |
| 1.3.6.1.4.1.4756.20.361.20.1.187 | Columnfa16e1et100ServErrSecRemote | read-only | current | 16E1-ET100(T/S) Series card, severely errored seconds of BERT result. |
| 1.3.6.1.4.1.4756.20.361.20.1.188 | Columnfa16e1et100BertFunctionRemote | read-write | current | 16E1-ET100(T/S) Series card bert function: 0:Disable 1:Enable |
| 1.3.6.1.4.1.4756.20.361.20.1.189 | Columnfa16e1et100ClrBertDataRemote | read-write | current | 16E1-ET100(T/S) Series card bert data clear: 0:Normal 1:Clear |
| 1.3.6.1.4.1.4756.20.361.20.1.190 | Columnfa16e1et100BertE1ChannelRemote | read-write | current | 16E1-ET100(T/S) Series card bert E1 channel number: 0:E1 channel 1 1:E1 channel 2 2:E1 channel 3 3:E1 channel 4 4:E1 channel 5 5:E1 channel 6 6:E1 channel 7 7:… |
| 1.3.6.1.4.1.4756.20.361.20.1.191 | Columnfa16e1et100RmonFunctionRemote | read-write | current | 16E1-ET100(T/S) Series RMON function : 0:Disable 1:Enable |
| 1.3.6.1.4.1.4756.20.361.20.1.192 | Columnfa16e1et100RmonTxRemote | read-only | current | 16E1-ET100(T/S) Series card RMON Tx counter. |
| 1.3.6.1.4.1.4756.20.361.20.1.193 | Columnfa16e1et100RmonRxRemote | read-only | current | 16E1-ET100(T/S) Series card RMON Rx counter. |
| 1.3.6.1.4.1.4756.20.361.20.1.194 | Columnfa16e1et100ClrRmonTxRemote | read-write | current | 16E1-ET100(T/S) Series card clear RMON Tx counter: 0:Normal 1:Clear |
| 1.3.6.1.4.1.4756.20.361.20.1.195 | Columnfa16e1et100ClrRmonRxRemote | read-write | current | 16E1-ET100(T/S) Series card clear RMON Rx counter: 0:Normal 1:Clear |
| 1.3.6.1.4.1.4756.20.361.20.1.196 | Columnfa16e1et100SfpRemote | read-only | current | 16E1-ET100(T/S) Series card, SFP existed: 0:No 1:Yes |
| 1.3.6.1.4.1.4756.20.361.20.1.197 | Columnfa16e1et100SfpVendorRemote | read-only | current | 16E1-ET100(T/S) Series card, Vendor name of SFP. |
| 1.3.6.1.4.1.4756.20.361.20.1.198 | Columnfa16e1et100SfpPartNoRemote | read-only | current | 16E1-ET100(T/S) Series card, Vendor part number of SFP. |
| 1.3.6.1.4.1.4756.20.361.20.1.199 | Columnfa16e1et100SfpFiberTypeRemote | read-only | current | 16E1-ET100(T/S) Series card, Fiber Type of SFP. |
| 1.3.6.1.4.1.4756.20.361.20.1.200 | Columnfa16e1et100SfpTxWaveLenRemote | read-only | current | 16E1-ET100(T/S) Series card, Tx Wave length of SFP. |
| 1.3.6.1.4.1.4756.20.361.20.1.201 | Columnfa16e1et100SfpRxWaveLenRemote | read-only | current | 16E1-ET100(T/S) Series card, Rx Wave length of SFP. |
| 1.3.6.1.4.1.4756.20.361.20.1.202 | Columnfa16e1et100SfpLinkLenRemote | read-only | current | 16E1-ET100(T/S) Series card, Link length of SFP. |
| 1.3.6.1.4.1.4756.20.361.20.1.203 | Columnfa16e1et100SfpModelIDRemote | read-only | current | 16E1-ET100(T/S) Series card, model ID of SFP. |
| 1.3.6.1.4.1.4756.20.361.20.1.204 | Columnfa16e1et100SfpVersionRemote | read-only | current | 16E1-ET100(T/S) Series card, the version of SFP. |
| 1.3.6.1.4.1.4756.20.361.20.1.205 | Columnfa16e1et100SfpModelTypeRemote | read-only | current | 16E1-ET100(T/S) Series card, model type of SFP. |
| 1.3.6.1.4.1.4756.20.361.20.1.206 | Columnfa16e1et100DDInformationRemote | read-only | current | 16E1-ET100(T/S) Series card, D/D information of SFP Supported: 0:No, 1:Yes |
| 1.3.6.1.4.1.4756.20.361.20.1.207 | Columnfa16e1et100DDRxSensRemote | read-only | current | 16E1-ET100(T/S) Series card, Sensitivity of D/D information. |
| 1.3.6.1.4.1.4756.20.361.20.1.208 | Columnfa16e1et100DDTxPowerRemote | read-only | current | 16E1-ET100(T/S) Series card, Tx power of D/D information. |
| 1.3.6.1.4.1.4756.20.361.20.1.209 | Columnfa16e1et100DDRxPowerRemote | read-only | current | 16E1-ET100(T/S) Series card, Rx power of D/D information. |
| 1.3.6.1.4.1.4756.20.361.20.1.210 | Columnfa16e1et100DDTempRemote | read-only | current | 16E1-ET100(T/S) Series card, Temperature of D/D information in degree C. |
| 1.3.6.1.4.1.4756.20.361.20.1.211 | Columnfa16e1et100DDBiasRemote | read-only | current | 16E1-ET100(T/S) Series card, BIAS of D/D information. |
| 1.3.6.1.4.1.4756.20.361.20.1.212 | Columnfa16e1et100DDVoltageRemote | read-only | current | 16E1-ET100(T/S) Series card, Voltage of D/D information. |
| 1.3.6.1.4.1.4756.20.361.20.1.213 | Columnfa16e1et100ChannelDefectRemote | read-write | current | 16E1-ET100(T/S) Series card Channel Defect: 0:Disable 4:1E-4 6:1E-6 |
| 1.3.6.1.4.1.4756.20.361.20.1.214 | Columnfa16e1et100LoopDetectionRemote | read-write | current | 16E1-ET100(T/S) Series card Loop Detection: 0:Disable 1:Enable |
| 1.3.6.1.4.1.4756.20.361.20.1.215 | Columnfa16e1et100LoopCh1Remote | read-only | current | 16E1-ET100(T/S) Series card E1 channel 1 Loop Check State: 0:No 1:Yes |
| 1.3.6.1.4.1.4756.20.361.20.1.216 | Columnfa16e1et100LoopCh2Remote | read-only | current | 16E1-ET100(T/S) Series card E1 channel 2 Loop Check State: 0:No 1:Yes |
| 1.3.6.1.4.1.4756.20.361.20.1.217 | Columnfa16e1et100LoopCh3Remote | read-only | current | 16E1-ET100(T/S) Series card E1 channel 3 Loop Check State: 0:No 1:Yes |
| 1.3.6.1.4.1.4756.20.361.20.1.218 | Columnfa16e1et100LoopCh4Remote | read-only | current | 16E1-ET100(T/S) Series card E1 channel 4 Loop Check State: 0:No 1:Yes |
| 1.3.6.1.4.1.4756.20.361.20.1.219 | Columnfa16e1et100LoopCh5Remote | read-only | current | 16E1-ET100(T/S) Series card E1 channel 5 Loop Check State: 0:No 1:Yes |
| 1.3.6.1.4.1.4756.20.361.20.1.220 | Columnfa16e1et100LoopCh6Remote | read-only | current | 16E1-ET100(T/S) Series card E1 channel 6 Loop Check State: 0:No 1:Yes |
| 1.3.6.1.4.1.4756.20.361.20.1.221 | Columnfa16e1et100LoopCh7Remote | read-only | current | 16E1-ET100(T/S) Series card E1 channel 7 Loop Check State: 0:No 1:Yes |
| 1.3.6.1.4.1.4756.20.361.20.1.222 | Columnfa16e1et100LoopCh8Remote | read-only | current | 16E1-ET100(T/S) Series card E1 channel 8 Loop Check State: 0:No 1:Yes |
| 1.3.6.1.4.1.4756.20.361.20.1.223 | Columnfa16e1et100LoopCh9Remote | read-only | current | 16E1-ET100(T/S) Series card E1 channel 9 Loop Check State: 0:No 1:Yes |
| 1.3.6.1.4.1.4756.20.361.20.1.224 | Columnfa16e1et100LoopCh10Remote | read-only | current | 16E1-ET100(T/S) Series card E1 channel 10 Loop Check State: 0:No 1:Yes |
| 1.3.6.1.4.1.4756.20.361.20.1.225 | Columnfa16e1et100LoopCh11Remote | read-only | current | 16E1-ET100(T/S) Series card E1 channel 11 Loop Check State: 0:No 1:Yes |
| 1.3.6.1.4.1.4756.20.361.20.1.226 | Columnfa16e1et100LoopCh12Remote | read-only | current | 16E1-ET100(T/S) Series card E1 channel 12 Loop Check State: 0:No 1:Yes |
| 1.3.6.1.4.1.4756.20.361.20.1.227 | Columnfa16e1et100LoopCh13Remote | read-only | current | 16E1-ET100(T/S) Series card E1 channel 13 Loop Check State: 0:No 1:Yes |
| 1.3.6.1.4.1.4756.20.361.20.1.228 | Columnfa16e1et100LoopCh14Remote | read-only | current | 16E1-ET100(T/S) Series card E1 channel 14 Loop Check State: 0:No 1:Yes |
| 1.3.6.1.4.1.4756.20.361.20.1.229 | Columnfa16e1et100LoopCh15Remote | read-only | current | 16E1-ET100(T/S) Series card E1 channel 15 Loop Check State: 0:No 1:Yes |
| 1.3.6.1.4.1.4756.20.361.20.1.230 | Columnfa16e1et100LoopCh16Remote | read-only | current | 16E1-ET100(T/S) Series card E1 channel 16 Loop Check State: 0:No 1:Yes |
| 1.3.6.1.4.1.4756.20.361.20.1.231 | Columnfa16e1et100DefectCh1Remote | read-only | current | 16E1-ET100(T/S) Series card E1 channel 1 Defect Status: 0:No 1:Yes |
| 1.3.6.1.4.1.4756.20.361.20.1.232 | Columnfa16e1et100DefectCh2Remote | read-only | current | 16E1-ET100(T/S) Series card E1 channel 2 Defect Status: 0:No 1:Yes |
| 1.3.6.1.4.1.4756.20.361.20.1.233 | Columnfa16e1et100DefectCh3Remote | read-only | current | 16E1-ET100(T/S) Series card E1 channel 3 Defect Status: 0:No 1:Yes |
| 1.3.6.1.4.1.4756.20.361.20.1.234 | Columnfa16e1et100DefectCh4Remote | read-only | current | 16E1-ET100(T/S) Series card E1 channel 4 Defect Status: 0:No 1:Yes |
| 1.3.6.1.4.1.4756.20.361.20.1.235 | Columnfa16e1et100DefectCh5Remote | read-only | current | 16E1-ET100(T/S) Series card E1 channel 5 Defect Status: 0:No 1:Yes |
| 1.3.6.1.4.1.4756.20.361.20.1.236 | Columnfa16e1et100DefectCh6Remote | read-only | current | 16E1-ET100(T/S) Series card E1 channel 6 Defect Status: 0:No 1:Yes |
| 1.3.6.1.4.1.4756.20.361.20.1.237 | Columnfa16e1et100DefectCh7Remote | read-only | current | 16E1-ET100(T/S) Series card E1 channel 7 Defect Status: 0:No 1:Yes |
| 1.3.6.1.4.1.4756.20.361.20.1.238 | Columnfa16e1et100DefectCh8Remote | read-only | current | 16E1-ET100(T/S) Series card E1 channel 8 Defect Status: 0:No 1:Yes |
| 1.3.6.1.4.1.4756.20.361.20.1.239 | Columnfa16e1et100DefectCh9Remote | read-only | current | 16E1-ET100(T/S) Series card E1 channel 9 Defect Status: 0:No 1:Yes |
| 1.3.6.1.4.1.4756.20.361.20.1.240 | Columnfa16e1et100DefectCh10Remote | read-only | current | 16E1-ET100(T/S) Series card E1 channel 10 Defect Status: 0:No 1:Yes |
| 1.3.6.1.4.1.4756.20.361.20.1.241 | Columnfa16e1et100DefectCh11Remote | read-only | current | 16E1-ET100(T/S) Series card E1 channel 11 Defect Status: 0:No 1:Yes |
| 1.3.6.1.4.1.4756.20.361.20.1.242 | Columnfa16e1et100DefectCh12Remote | read-only | current | 16E1-ET100(T/S) Series card E1 channel 12 Defect Status: 0:No 1:Yes |
| 1.3.6.1.4.1.4756.20.361.20.1.243 | Columnfa16e1et100DefectCh13Remote | read-only | current | 16E1-ET100(T/S) Series card E1 channel 13 Defect Status: 0:No 1:Yes |
| 1.3.6.1.4.1.4756.20.361.20.1.244 | Columnfa16e1et100DefectCh14Remote | read-only | current | 16E1-ET100(T/S) Series card E1 channel 14 Defect Status: 0:No 1:Yes |
| 1.3.6.1.4.1.4756.20.361.20.1.245 | Columnfa16e1et100DefectCh15Remote | read-only | current | 16E1-ET100(T/S) Series card E1 channel 15 Defect Status: 0:No 1:Yes |
| 1.3.6.1.4.1.4756.20.361.20.1.246 | Columnfa16e1et100DefectCh16Remote | read-only | current | 16E1-ET100(T/S) Series card E1 channel 16 Defect Status: 0:No 1:Yes |
| 1.3.6.1.4.1.4756.20.361.20.1.247 | Columnfa16e1et100FxSignalRemote | read-only | current | 16E1-ET100(T/S) Series card Fiber signal detect(SD): 0:Fiber unplugged 1:Signal detected |
| 1.3.6.1.4.1.4756.20.361.20.1.248 | Columnfa16e1et100PortResetRemote | read-write | current | 16E1-ET100(T/S) Series card Port Reset: 0:Action 1:Off |
| 1.3.6.1.4.1.4756.20.361.20.1.249 | Columnfa16e1et100VLANModeRemote | read-write | current | 16E1-ET100(T/S) Series card VLAN mode: 0:MODE2 1:MODE1 |
| 1.3.6.1.4.1.4756.20.361.20.1.250 | Columnfa16e1et100ETagSelectEntryRemote | read-write | current | 16E1-ET100(T/S) Series card ETag select entry: |
| 1.3.6.1.4.1.4756.20.361.20.1.251 | Columnfa16e1et100ETagMethodRemote | read-write | current | 16E1-ET100(T/S) Series card ETag Method: 0: Intouch 1: Add Tag 2: Remove Tag |
| 1.3.6.1.4.1.4756.20.361.20.1.252 | Columnfa16e1et100VLANTableVID1Remote | read-write | current | 16E1-ET100(T/S) Series card VLAN Table: VLAN ID1 |
| 1.3.6.1.4.1.4756.20.361.20.1.253 | Columnfa16e1et100VLANTableVID2Remote | read-write | current | 16E1-ET100(T/S) Series card VLAN Table: VLAN ID2 |
| 1.3.6.1.4.1.4756.20.361.20.1.254 | Columnfa16e1et100VLANTableVID3Remote | read-write | current | 16E1-ET100(T/S) Series card VLAN Table: VLAN ID3 |
| 1.3.6.1.4.1.4756.20.361.20.1.255 | Columnfa16e1et100VLANTableVID4Remote | read-write | current | 16E1-ET100(T/S) Series card VLAN Table: VLAN ID4 |
| 1.3.6.1.4.1.4756.20.361.20.1.256 | Columnfa16e1et100VLANTableVID5Remote | read-write | current | 16E1-ET100(T/S) Series card VLAN Table: VLAN ID5 |
| 1.3.6.1.4.1.4756.20.361.20.1.257 | Columnfa16e1et100VLANTableVID6Remote | read-write | current | 16E1-ET100(T/S) Series card VLAN Table: VLAN ID6 |
| 1.3.6.1.4.1.4756.20.361.20.1.258 | Columnfa16e1et100VLANTableVID7Remote | read-write | current | 16E1-ET100(T/S) Series card VLAN Table: VLAN ID7 |
| 1.3.6.1.4.1.4756.20.361.20.1.259 | Columnfa16e1et100VLANTableVID8Remote | read-write | current | 16E1-ET100(T/S) Series card VLAN Table: VLAN ID8 |
| 1.3.6.1.4.1.4756.20.361.20.1.260 | Columnfa16e1et100VLANTableVID9Remote | read-write | current | 16E1-ET100(T/S) Series card VLAN Table: VLAN ID9 |
| 1.3.6.1.4.1.4756.20.361.20.1.261 | Columnfa16e1et100VLANTableVID10Remote | read-write | current | 16E1-ET100(T/S) Series card VLAN Table: VLAN ID10 |
| 1.3.6.1.4.1.4756.20.361.20.1.262 | Columnfa16e1et100VLANTableVID11Remote | read-write | current | 16E1-ET100(T/S) Series card VLAN Table: VLAN ID11 |
| 1.3.6.1.4.1.4756.20.361.20.1.263 | Columnfa16e1et100VLANTableVID12Remote | read-write | current | 16E1-ET100(T/S) Series card VLAN Table: VLAN ID12 |
| 1.3.6.1.4.1.4756.20.361.20.1.264 | Columnfa16e1et100VLANTableVID13Remote | read-write | current | 16E1-ET100(T/S) Series card VLAN Table: VLAN ID13 |
| 1.3.6.1.4.1.4756.20.361.20.1.265 | Columnfa16e1et100VLANTableVID14Remote | read-write | current | 16E1-ET100(T/S) Series card VLAN Table: VLAN ID14 |
| 1.3.6.1.4.1.4756.20.361.20.1.266 | Columnfa16e1et100VLANTableVID15Remote | read-write | current | 16E1-ET100(T/S) Series card VLAN Table: VLAN ID15 |
| 1.3.6.1.4.1.4756.20.361.20.1.267 | Columnfa16e1et100VLANTableVID16Remote | read-write | current | 16E1-ET100(T/S) Series card VLAN Table: VLAN ID16 |
| 1.3.6.1.4.1.4756.20.370 | Nodef10GECards | |||
| 1.3.6.1.4.1.4756.20.370.20 | Tablef10GETable | not-accessible | current | A list of local FRM220-10GE card entries. The number of entries is f10GE. |
| 1.3.6.1.4.1.4756.20.370.20.1 | Rowf10GEEntry | not-accessible | current | An entry containing management information applicable to a particular local FRM220-10GE card. |
| 1.3.6.1.4.1.4756.20.370.20.1.1 | Columnf10GEChassisIndex | read-only | current | A unique value for each local card. It is the chassis location number. |
| 1.3.6.1.4.1.4756.20.370.20.1.2 | Columnf10GESlotIndex | read-only | current | A unique value for each local card. It is the slot location number. |
| 1.3.6.1.4.1.4756.20.370.20.1.3 | Columnf10GECardHWVer | read-only | current | Local FRM220-10GE card hardware version x.xxx |
| 1.3.6.1.4.1.4756.20.370.20.1.4 | Columnf10GECardFWVer | read-only | current | Local FRM220-10GE card firmware version x.xxx |
| 1.3.6.1.4.1.4756.20.370.20.1.5 | Columnf10GECardCPLDVer | read-only | current | Local FRM220-10GE card CPLD version x.xxx |
| 1.3.6.1.4.1.4756.20.370.20.1.6 | Columnf10GECardFPGAVer | read-only | current | Local FRM220-10GE card FPGA version x.xxx |
| 1.3.6.1.4.1.4756.20.370.20.1.7 | Columnf10GEModel | read-only | current | Local CardType: 0:FRM220-10GETX 1:FRM220-10GETS |
| 1.3.6.1.4.1.4756.20.370.20.1.8 | Columnf10GEPortActive | read-write | current | Local FRM220-10GE card active: 0:Inactive 1:Active |
| 1.3.6.1.4.1.4756.20.370.20.1.9 | Columnf10GEPortReset | read-write | current | Force local FRM220-10GE card to reset mode: 0:Off 1:Action |
| 1.3.6.1.4.1.4756.20.370.20.1.10 | Columnf10GESettoDefault | read-write | current | Force local FRM220-10GE card set to default mode: 0:Off 1:Action |
| 1.3.6.1.4.1.4756.20.370.20.1.11 | Columnf10GEUtpActive | read-write | current | Force local FRM220-10GE card UTP active: 0:Disalbe 1:Enable |
| 1.3.6.1.4.1.4756.20.370.20.1.12 | Columnf10GEUtpLink | read-only | current | Local FRM220-10GE card UTP link status: 0:Down 1:Up |
| 1.3.6.1.4.1.4756.20.370.20.1.13 | Columnf10GEUtpNego | read-write | current | Local FRM220-10GE card UTP negotiation: 0:Manual 1:Auto |
| 1.3.6.1.4.1.4756.20.370.20.1.14 | Columnf10GEUtpSpeed | read-write | current | Local FRM220-10GE card UTP speed: 0:10G Base-T 1:1000 Base-T 2:100 Base-TX |
| 1.3.6.1.4.1.4756.20.370.20.1.15 | Columnf10GEUtpSpeedSTS | read-only | current | Local FRM220-10GE card UTP speed status: 0:10G Base-T 1:1000 Base-T 2:100 Base-TX 3:No Link |
| 1.3.6.1.4.1.4756.20.370.20.1.16 | Columnf10GEUtpShortReach | read-write | current | Local FRM220-10GE card UTP short reach: 0:Disable 1:Enable |
| 1.3.6.1.4.1.4756.20.370.20.1.17 | Columnf10GEUtpLoopback | read-write | current | Local FRM220-10GE card UTP loop back: 0:Disable 1:Enable |
| 1.3.6.1.4.1.4756.20.370.20.1.18 | Columnf10GEUtpCableLength | read-only | current | Local FRM220-10GE card UTP cable length: |
| 1.3.6.1.4.1.4756.20.370.20.1.19 | Columnf10GEFxActive | read-write | current | Local FRM220-10GE card fiber active: 0:Disable 1:Enable |
| 1.3.6.1.4.1.4756.20.370.20.1.20 | Columnf10GEFxLink | read-only | current | Local FRM220-10GE card fiber link status: 0:Down 1:Up |
| 1.3.6.1.4.1.4756.20.370.20.1.21 | Columnf10GEFxSpeedSTS | read-only | current | Local FRM220-10GE card fiber speed status: 0:No link 1:10G 2:1000M 3:100M |
| 1.3.6.1.4.1.4756.20.370.20.1.22 | Columnf10GEFxDDM | read-only | current | Local FRM220-10GE card fiber DDM status: 0:None 1:DDM |
| 1.3.6.1.4.1.4756.20.370.20.1.23 | Columnf10GEFxTxFail | read-only | current | Local FRM220-10GE card fiber Tx fail: 0:Normal 1:Detect |
| 1.3.6.1.4.1.4756.20.370.20.1.24 | Columnf10GEFxAls | read-write | current | Local FRM220-10GE card fiber auto laser shutdown: 0:Disable 1:Enable |
| 1.3.6.1.4.1.4756.20.370.20.1.25 | Columnf10GEFxLoopback | read-write | current | Local FRM220-10GE card fiber loopback: 0:Disable 1:Enable |
| 1.3.6.1.4.1.4756.20.370.20.1.26 | Columnf10GELfpMode | read-write | current | Local FRM220-10GE card Link Fault Pass-through mode: 0:Disable 1:Enable |
| 1.3.6.1.4.1.4756.20.370.20.1.27 | Columnf10GEThermal | read-write | current | Local FRM220-10GE card thermal protection: 0:80 1:90 2:100 3:110 |
| 1.3.6.1.4.1.4756.20.370.20.1.28 | Columnf10GETempSTS | read-only | current | Local FRM220-10GE card temperature status : 0:Normal 1:Over |
| 1.3.6.1.4.1.4756.20.370.20.1.29 | Columnf10GECurrentTemp | read-only | current | Local FRM220-10GE card current temperature |
| 1.3.6.1.4.1.4756.20.370.20.1.30 | Columnf10GEAlarm | read-only | current | Local FRM220-10GE card alarm : 0:Off 1:On |
| 1.3.6.1.4.1.4756.20.370.20.1.31 | Columnf10GEFxDD | read-only | current | Local FRM220-10GE card fiber Digital Diagnostic function: 0:No 1:Yes |
| 1.3.6.1.4.1.4756.20.370.20.1.32 | Columnf10GEDDVendor | read-only | current | Local FRM220-10GE card fiber D/D information: Vendor name |
| 1.3.6.1.4.1.4756.20.370.20.1.33 | Columnf10GEDDPartNo | read-only | current | Local FRM220-10GE card fiber D/D information: Vendor part number |
| 1.3.6.1.4.1.4756.20.370.20.1.34 | Columnf10GEDDFiberType | read-only | current | Local FRM220-10GE card fiber D/D information: Fiber Type |
| 1.3.6.1.4.1.4756.20.370.20.1.35 | Columnf10GEDDWaveLen | read-only | current | Local FRM220-10GE card fiber D/D information: Wave length |
| 1.3.6.1.4.1.4756.20.370.20.1.36 | Columnf10GEDDWaveLen2 | read-only | current | Local FRM220-10GE card fiber D/D information: Wave length 2 |
| 1.3.6.1.4.1.4756.20.370.20.1.37 | Columnf10GEDDLinkLen | read-only | current | Local FRM220-10GE card fiber D/D information: Link length |
| 1.3.6.1.4.1.4756.20.370.20.1.38 | Columnf10GEDDLenUnit | read-only | current | Local FRM220-10GE card fiber D/D information: Length Unit |
| 1.3.6.1.4.1.4756.20.370.20.1.39 | Columnf10GEDDStatus | read-only | current | Local FRM220-10GE card fiber D/D information: Status Support |
| 1.3.6.1.4.1.4756.20.370.20.1.40 | Columnf10GEDDRxSens | read-only | current | Local FRM220-10GE card fiber D/D information: Rx Sensitivity |
| 1.3.6.1.4.1.4756.20.370.20.1.41 | Columnf10GEDDTxPWR | read-only | current | Local FRM220-10GE card fiber D/D information: Tx power |
| 1.3.6.1.4.1.4756.20.370.20.1.42 | Columnf10GEDDRxPWR | read-only | current | Local FRM220-10GE card fiber D/D information: Rx power |
| 1.3.6.1.4.1.4756.20.370.20.1.43 | Columnf10GEDDTemp | read-only | current | Local FRM220-10GE card fiber D/D information: Temperature in degree C |
| 1.3.6.1.4.1.4756.20.370.20.1.44 | Columnf10GEDDPWRMargin | read-only | current | Local FRM220-10GE card fiber D/D information: Power margin |
| 1.3.6.1.4.1.4756.20.370.20.1.45 | Columnf10GEDDPWRLoss | read-only | current | Local FRM220-10GE card fiber D/D information: Power loss |
| 1.3.6.1.4.1.4756.20.380 | Nodeeoe1GLocalCards | |||
| 1.3.6.1.4.1.4756.20.380.20 | Tableeoe1GLocalTable | not-accessible | current | A list of local FRM220-EOE1/G card entries. The number of entries is eoe1G-No-L. |
| 1.3.6.1.4.1.4756.20.380.20.1 | Roweoe1GLocalEntry | not-accessible | current | An entry containing management information applicable to a particular local FRM220-Eoe1G series card. |
| 1.3.6.1.4.1.4756.20.380.20.1.1 | Columneoe1GChassisIndexLocal | read-only | current | A unique value for each card. It starts from 0 to 9 contiguously. |
| 1.3.6.1.4.1.4756.20.380.20.1.2 | Columneoe1GSlotIndexLocal | read-only | current | A unique value for each card. It starts from 1 to 20 contiguously. |
| 1.3.6.1.4.1.4756.20.380.20.1.3 | Columneoe1GCardHWVerLocal | read-only | current | Eoe1/G Series card hardware version x.xxx |
| 1.3.6.1.4.1.4756.20.380.20.1.4 | Columneoe1GCardFWVerLocal | read-only | current | Eoe1/G Series card firmware version x.xxx |
| 1.3.6.1.4.1.4756.20.380.20.1.5 | Columneoe1GCardCPLDVerLocal | read-only | current | Eoe1/G Series card CPLD version x.xxx |
| 1.3.6.1.4.1.4756.20.380.20.1.6 | Columneoe1GCardFPGAVerLocal | read-only | current | Eoe1/G Series card FPGA version x.xxx |
| 1.3.6.1.4.1.4756.20.380.20.1.7 | Columneoe1GPortResetLocal | read-write | current | Eoe1/G Series card system status: 0:Off 1:Trigger |
| 1.3.6.1.4.1.4756.20.380.20.1.8 | Columneoe1GSetToDefaultLocal | read-write | current | Eoe1/G Series card port set to default: 0:Off 1:Trigger |
| 1.3.6.1.4.1.4756.20.380.20.1.9 | Columneoe1GLOSLocal | read-only | current | Eoe1/G Series card LOS status: 0:No 1:Yes |
| 1.3.6.1.4.1.4756.20.380.20.1.10 | Columneoe1GLOFLocal | read-only | current | Eoe1/G Series card LOF status: 0:No 1:Yes |
| 1.3.6.1.4.1.4756.20.380.20.1.11 | Columneoe1GAISLocal | read-only | current | Eoe1/G Series card AIS status: 0:No 1:Yes |
| 1.3.6.1.4.1.4756.20.380.20.1.12 | Columneoe1GRAILocal | read-only | current | Eoe1/G Series card RAI status: 0:No 1:Yes |
| 1.3.6.1.4.1.4756.20.380.20.1.13 | Columneoe1GCRCLocal | read-only | current | Eoe1/G Series card CRC status: 0:No 1:Yes |
| 1.3.6.1.4.1.4756.20.380.20.1.14 | Columneoe1GBPVLocal | read-only | current | Eoe1/G Series card BPV status: 0:No 1:Yes |
| 1.3.6.1.4.1.4756.20.380.20.1.15 | Columneoe1GLoopStatusLocal | read-only | current | Eoe1/G Series card Loop status: 0:No 1:Yes |
| 1.3.6.1.4.1.4756.20.380.20.1.16 | Columneoe1GE1ModeLocal | read-write | current | Eoe1/G Series card E1 mode: 0:Unframe 1:Frame |
| 1.3.6.1.4.1.4756.20.380.20.1.17 | Columneoe1GE1LoopBackLocal | read-write | current | Eoe1/G Series card E1 loopback : 0:OFF 1:LLB 2:RLB |
| 1.3.6.1.4.1.4756.20.380.20.1.18 | Columneoe1GE1LoopDetectionLocal | read-write | current | Eoe1/G Series card E1 loop detection: 0:Disable 1:Enalbe |
| 1.3.6.1.4.1.4756.20.380.20.1.19 | Columneoe1GE1HDLCLocal | read-write | current | Eoe1/G Series card E1 HDLC: 0:Inverse 1:Consisten |
| 1.3.6.1.4.1.4756.20.380.20.1.20 | Columneoe1GTimingSourceLocal | read-write | current | Eoe1/G Series card timing source: 0:Recovery from E1 receive 1:Internal oscillator |
| 1.3.6.1.4.1.4756.20.380.20.1.21 | Columneoe1GFailOverLocal | read-write | current | Eoe1/G Series card failover: 0:Disalbe 1:Enable |
| 1.3.6.1.4.1.4756.20.380.20.1.22 | Columneoe1GEncapsulationLocal | read-write | current | Eoe1/G Series card encapsulation: 0:GFP 1:HDLC |
| 1.3.6.1.4.1.4756.20.380.20.1.23 | Columneoe1GNetManageLocal | read-write | current | Eoe1/G Series card net manage: 0:Disable 1:Enable |
| 1.3.6.1.4.1.4756.20.380.20.1.24 | Columneoe1GTagLocal | read-write | current | Eoe1/G Series card tag mode: 0:Untag 1:tag 2:No Touch |
| 1.3.6.1.4.1.4756.20.380.20.1.25 | Columneoe1GInsertLocal | read-write | current | Eoe1/G Series card insert mode: 0:Disable 1:Enable |
| 1.3.6.1.4.1.4756.20.380.20.1.26 | Columneoe1GUtpLinkLocal | read-only | current | Eoe1/G Series card UTP link status: 0:Down 1:Up |
| 1.3.6.1.4.1.4756.20.380.20.1.27 | Columneoe1GUtpActiveLocal | read-write | current | Eoe1/G Series card UTP port active: 0:Disable 1:Enable |
| 1.3.6.1.4.1.4756.20.380.20.1.28 | Columneoe1GUtpNegoStatusLocal | read-only | current | Eoe1/G Series card UTP negoiation status: 0:Manual 1:Auto |
| 1.3.6.1.4.1.4756.20.380.20.1.29 | Columneoe1GUtpSpeedStatusLocal | read-only | current | Eoe1/G Series card UTP speed status: 0:10M 1:100M |
| 1.3.6.1.4.1.4756.20.380.20.1.30 | Columneoe1GUtpDuplexStatusLocal | read-only | current | Eoe1/G Series card UTP duplex status: 0:Half 1:Full |
| 1.3.6.1.4.1.4756.20.380.20.1.31 | Columneoe1GUtpNegoLocal | read-write | current | Eoe1/G Series card UTP negoiation mode: 0:Manual 1:Auto |
| 1.3.6.1.4.1.4756.20.380.20.1.32 | Columneoe1GUtpSpeedLocal | read-write | current | Eoe1/G Series card UTP speed mode: 0:10M 1:100M |
| 1.3.6.1.4.1.4756.20.380.20.1.33 | Columneoe1GUtpDuplexLocal | read-write | current | Eoe1/G Series card UTP duplex mode: 0:Half 1:Full |
| 1.3.6.1.4.1.4756.20.380.20.1.34 | Columneoe1GUtpFlowControlLocal | read-write | current | Eoe1/G Series card UTP flow control mode: 0:Disable 1:Enable |
| 1.3.6.1.4.1.4756.20.380.20.1.35 | Columneoe1GBandwidthFUNLocal | read-write | current | Eoe1/G Series card bandwidth mode: 1:disable(0), 2:32k*N(0~255)(1), 3:521k*N(0~200)(2), |
| 1.3.6.1.4.1.4756.20.380.20.1.36 | Columneoe1GBandwidthLocal | read-write | current | Eoe1/G Series bandwidth: bandwidth mode is 32k*N , The bandwidth is restricted to 0 ~ 255 bandwidth mode is 512k*N , The bandwidth is restricted to 0 ~ 200 |
| 1.3.6.1.4.1.4756.20.380.20.1.37 | Columneoe1GBandwidthSpeedLocal | read-only | current | Eoe1/G Series bandwidthspeed: |
| 1.3.6.1.4.1.4756.20.380.20.1.38 | Columneoe1GVlanFUNLocal | read-write | current | Eoe1/G Series card Vlan mode: 0:Disable 1:Enable |
| 1.3.6.1.4.1.4756.20.380.20.1.39 | Columneoe1GVlanIDLocal | read-write | current | Eoe1/G Series card VLAN ID: The ID is restricted to 1 ~ 4095 |
| 1.3.6.1.4.1.4756.20.380.20.1.40 | Columneoe1GRemoteLinkLocal | read-only | current | Eoe1/G Series card remote link status: 0:Down 1:Up |
| 1.3.6.1.4.1.4756.20.380.20.1.41 | Columneoe1GRemotePWRLocal | read-only | current | Eoe1/G Series card remote power status: 0:Normal 1:Power Off |
| 1.3.6.1.4.1.4756.20.380.20.1.42 | Columneoe1GBertFUNLocal | read-write | current | Eoe1/G Series card bert mode: 0:Disable 1:Enable |
| 1.3.6.1.4.1.4756.20.380.20.1.43 | Columneoe1GBertClearLocal | read-write | current | Eoe1/G Series card bert data clear: 0:Normal 1:Clear |
| 1.3.6.1.4.1.4756.20.380.20.1.44 | Columneoe1GLSBToESLocal | read-only | current | Eoe1/G) Series card, errored seconds of BERT result. |
| 1.3.6.1.4.1.4756.20.380.20.1.45 | Columneoe1GLSBToSESLocal | read-only | current | 5E1-ET100(T/S) Series card, severely errored seconds of BERT result. |
| 1.3.6.1.4.1.4756.20.380.20.1.46 | Columneoe1GRmonFUNLocal | read-write | current | Eoe1/G Series card Rmon mode: 0:Disable 1:Enable |
| 1.3.6.1.4.1.4756.20.380.20.1.47 | Columneoe1GRmonRxPKTClearLocal | read-write | current | Eoe1/G Series card rmon rx packet clear: 0:Normal 1:Clear |
| 1.3.6.1.4.1.4756.20.380.20.1.48 | Columneoe1GRmonRxByteClearLocal | read-write | current | Eoe1/G Series card rmon rx byte clear: 0:Normal 1:Clear |
| 1.3.6.1.4.1.4756.20.380.20.1.49 | Columneoe1GRmonRxPKTLocal | read-only | current | Eoe1/G Series card RMON Rx packet counter. |
| 1.3.6.1.4.1.4756.20.380.20.1.50 | Columneoe1GRmonRxByteLocal | read-only | current | Eoe1/G Series card RMON Rx byte counter. |
| 1.3.6.1.4.1.4756.20.381 | Nodeeoe1GRemoteCards | |||
| 1.3.6.1.4.1.4756.20.381.20 | Tableeoe1GRemoteTable | not-accessible | current | A list of local FRM220-EOE1/G card entries. The number of entries is eoe1G-No-L. |
| 1.3.6.1.4.1.4756.20.381.20.1 | Roweoe1GRemoteEntry | not-accessible | current | An entry containing management information applicable to a particular local FRM220-Eoe1G series card. |
| 1.3.6.1.4.1.4756.20.381.20.1.1 | Columneoe1GChassisIndexRemote | read-only | current | A unique value for each card. It starts from 0 to 9 contiguously. |
| 1.3.6.1.4.1.4756.20.381.20.1.2 | Columneoe1GSlotIndexRemote | read-only | current | A unique value for each card. It starts from 1 to 20 contiguously. |
| 1.3.6.1.4.1.4756.20.381.20.1.3 | Columneoe1GCardHWVerRemote | read-only | current | Eoe1/G Series card hardware version x.xxx |
| 1.3.6.1.4.1.4756.20.381.20.1.4 | Columneoe1GCardFWVerRemote | read-only | current | Eoe1/G Series card firmware version x.xxx |
| 1.3.6.1.4.1.4756.20.381.20.1.5 | Columneoe1GCardCPLDVerRemote | read-only | current | Eoe1/G Series card CPLD version x.xxx |
| 1.3.6.1.4.1.4756.20.381.20.1.6 | Columneoe1GCardFPGAVerRemote | read-only | current | Eoe1/G Series card FPGA version x.xxx |
| 1.3.6.1.4.1.4756.20.381.20.1.7 | Columneoe1GPortResetRemote | read-write | current | Eoe1/G Series card system status: 0:Off 1:Trigger |
| 1.3.6.1.4.1.4756.20.381.20.1.8 | Columneoe1GSetToDefaultRemote | read-write | current | Eoe1/G Series card port set to default: 0:Off 1:Trigger |
| 1.3.6.1.4.1.4756.20.381.20.1.9 | Columneoe1GLOSRemote | read-only | current | Eoe1/G Series card LOS status: 0:No 1:Yes |
| 1.3.6.1.4.1.4756.20.381.20.1.10 | Columneoe1GLOFRemote | read-only | current | Eoe1/G Series card LOF status: 0:No 1:Yes |
| 1.3.6.1.4.1.4756.20.381.20.1.11 | Columneoe1GAISRemote | read-only | current | Eoe1/G Series card AIS status: 0:No 1:Yes |
| 1.3.6.1.4.1.4756.20.381.20.1.12 | Columneoe1GRAIRemote | read-only | current | Eoe1/G Series card RAI status: 0:No 1:Yes |
| 1.3.6.1.4.1.4756.20.381.20.1.13 | Columneoe1GCRCRemote | read-only | current | Eoe1/G Series card CRC status: 0:No 1:Yes |
| 1.3.6.1.4.1.4756.20.381.20.1.14 | Columneoe1GBPVRemote | read-only | current | Eoe1/G Series card BPV status: 0:No 1:Yes |
| 1.3.6.1.4.1.4756.20.381.20.1.15 | Columneoe1GLoopStatusRemote | read-only | current | Eoe1/G Series card Loop status: 0:No 1:Yes |
| 1.3.6.1.4.1.4756.20.381.20.1.16 | Columneoe1GE1ModeRemote | read-write | current | Eoe1/G Series card E1 mode: 0:Unframe 1:Frame |
| 1.3.6.1.4.1.4756.20.381.20.1.17 | Columneoe1GE1LoopDetectionRemote | read-write | current | Eoe1/G Series card E1 loop detection: 0:Disable 1:Enalbe |
| 1.3.6.1.4.1.4756.20.381.20.1.18 | Columneoe1GE1HDLCRemote | read-write | current | Eoe1/G Series card E1 HDLC: 0:Inverse 1:Consisten |
| 1.3.6.1.4.1.4756.20.381.20.1.19 | Columneoe1GTimingSourceRemote | read-write | current | Eoe1/G Series card timing source: 0:Recovery from E1 receive 1:Internal oscillator |
| 1.3.6.1.4.1.4756.20.381.20.1.20 | Columneoe1GFailOverRemote | read-write | current | Eoe1/G Series card failover: 0:Disalbe 1:Enable |
| 1.3.6.1.4.1.4756.20.381.20.1.21 | Columneoe1GEncapsulationRemote | read-write | current | Eoe1/G Series card encapsulation: 0:GFP 1:HDLC |
| 1.3.6.1.4.1.4756.20.381.20.1.22 | Columneoe1GNetManageRemote | read-write | current | Eoe1/G Series card net manage: 0:Disable 1:Enable |
| 1.3.6.1.4.1.4756.20.381.20.1.23 | Columneoe1GTagRemote | read-write | current | Eoe1/G Series card tag mode: 0:Untag 1:tag 2:No Touch |
| 1.3.6.1.4.1.4756.20.381.20.1.24 | Columneoe1GInsertRemote | read-write | current | Eoe1/G Series card insert mode: 0:Disable 1:Enable |
| 1.3.6.1.4.1.4756.20.381.20.1.25 | Columneoe1GUtpLinkRemote | read-only | current | Eoe1/G Series card UTP link status: 0:Down 1:Up |
| 1.3.6.1.4.1.4756.20.381.20.1.26 | Columneoe1GUtpActiveRemote | read-write | current | Eoe1/G Series card UTP port active: 0:Disable 1:Enable |
| 1.3.6.1.4.1.4756.20.381.20.1.27 | Columneoe1GUtpNegoStatusRemote | read-only | current | Eoe1/G Series card UTP negoiation status: 0:Manual 1:Auto |
| 1.3.6.1.4.1.4756.20.381.20.1.28 | Columneoe1GUtpSpeedStatusRemote | read-only | current | Eoe1/G Series card UTP speed status: 0:10M 1:100M |
| 1.3.6.1.4.1.4756.20.381.20.1.29 | Columneoe1GUtpDuplexStatusRemote | read-only | current | Eoe1/G Series card UTP duplex status: 0:Half 1:Full |
| 1.3.6.1.4.1.4756.20.381.20.1.30 | Columneoe1GUtpNegoRemote | read-write | current | Eoe1/G Series card UTP negoiation mode: 0:Manual 1:Auto |
| 1.3.6.1.4.1.4756.20.381.20.1.31 | Columneoe1GUtpSpeedRemote | read-write | current | Eoe1/G Series card UTP speed mode: 0:10M 1:100M |
| 1.3.6.1.4.1.4756.20.381.20.1.32 | Columneoe1GUtpDuplexRemote | read-write | current | Eoe1/G Series card UTP duplex mode: 0:Half 1:Full |
| 1.3.6.1.4.1.4756.20.381.20.1.33 | Columneoe1GUtpFlowControlRemote | read-write | current | Eoe1/G Series card UTP flow control mode: 0:Disable 1:Enable |
| 1.3.6.1.4.1.4756.20.381.20.1.34 | Columneoe1GBandwidthFUNRemote | read-write | current | Eoe1/G Series card bandwidth mode: 1:disable(0), 2:32k*N(0~255)(1), 3:521k*N(0~200)(2), |
| 1.3.6.1.4.1.4756.20.381.20.1.35 | Columneoe1GBandwidthRemote | read-write | current | Eoe1/G Series bandwidth: bandwidth mode is 32k*N , The bandwidth is restricted to 0 ~ 255 bandwidth mode is 512k*N , The bandwidth is restricted to 0 ~ 200 |
| 1.3.6.1.4.1.4756.20.381.20.1.36 | Columneoe1GBandwidthSpeedRemote | read-only | current | Eoe1/G Series bandwidthspeed: |
| 1.3.6.1.4.1.4756.20.381.20.1.37 | Columneoe1GVlanFUNRemote | read-write | current | Eoe1/G Series card Vlan mode: 0:Disable 1:Enable |
| 1.3.6.1.4.1.4756.20.381.20.1.38 | Columneoe1GVlanIDRemote | read-write | current | Eoe1/G Series card VLAN ID: The ID is restricted to 1 ~ 4095 |
| 1.3.6.1.4.1.4756.20.381.20.1.39 | Columneoe1GRemoteLinkRemote | read-only | current | Eoe1/G Series card remote link status: 0:Down 1:Up |
| 1.3.6.1.4.1.4756.20.381.20.1.40 | Columneoe1GRemotePWRRemote | read-only | current | Eoe1/G Series card remote power status: 0:Normal 1:Power Off |
| 1.3.6.1.4.1.4756.20.381.20.1.41 | Columneoe1GRmonFUNRemote | read-write | current | Eoe1/G Series card Rmon mode: 0:Disable 1:Enable |
| 1.3.6.1.4.1.4756.20.381.20.1.42 | Columneoe1GRmonRxPKTClearRemote | read-write | current | Eoe1/G Series card rmon rx packet clear: 0:Normal 1:Clear |
| 1.3.6.1.4.1.4756.20.381.20.1.43 | Columneoe1GRmonRxByteClearRemote | read-write | current | Eoe1/G Series card rmon rx byte clear: 0:Normal 1:Clear |
| 1.3.6.1.4.1.4756.20.381.20.1.44 | Columneoe1GRmonRxPKTRemote | read-only | current | Eoe1/G Series card RMON Rx packet counter. |
| 1.3.6.1.4.1.4756.20.381.20.1.45 | Columneoe1GRmonRxByteRemote | read-only | current | Eoe1/G Series card RMON Rx byte counter. |
| 1.3.6.1.4.1.4756.20.390 | Nodef1000DSCards | |||
| 1.3.6.1.4.1.4756.20.390.20 | Tablef1000DSTable | not-accessible | current | A list of FRM220-f1000DS card entries. |
| 1.3.6.1.4.1.4756.20.390.20.1 | Rowf1000DSEntry | not-accessible | current | An entry containing management information applicable to a particular local FRM220-f1000DS card. |
| 1.3.6.1.4.1.4756.20.390.20.1.1 | Columnf1000DSChassisIndex | read-only | current | A unique value for each local card. It is the chassis location number. |
| 1.3.6.1.4.1.4756.20.390.20.1.2 | Columnf1000DSSlotIndex | read-only | current | A unique value for each local card. It is the slot location number. |
| 1.3.6.1.4.1.4756.20.390.20.1.3 | Columnf1000DSCardHWVer | read-only | current | FRM220-f1000DS card hardware version x.xxx |
| 1.3.6.1.4.1.4756.20.390.20.1.4 | Columnf1000DSCardFWVer | read-only | current | FRM220-f1000DS card firmware version x.xxx |
| 1.3.6.1.4.1.4756.20.390.20.1.5 | Columnf1000DSCardCPLDVer | read-only | current | FRM220-f1000DS card CPLD version x.xxx |
| 1.3.6.1.4.1.4756.20.390.20.1.6 | Columnf1000DSCardFPGAVer | read-only | current | FRM220-f1000DS card FPGA version x.xxx |
| 1.3.6.1.4.1.4756.20.390.20.1.7 | Columnf1000DSModel | read-only | current | FRM220-f1000DS card model |
| 1.3.6.1.4.1.4756.20.390.20.1.8 | Columnf1000DSPortActive | read-write | current | FRM220-f1000DS card port active: 0:Disable 1:Enable |
| 1.3.6.1.4.1.4756.20.390.20.1.9 | Columnf1000DSPortReset | read-write | current | Force FRM220-f1000DS card reset mode: 0:Off 1:Action |
| 1.3.6.1.4.1.4756.20.390.20.1.10 | Columnf1000DSSetDefault | read-write | current | Force FRM220-f1000DS card SetDefault mode: 0:Off 1:Action |
| 1.3.6.1.4.1.4756.20.390.20.1.11 | Columnf1000DSLfpMode | read-write | current | Force FRM220-f1000DS card LFP mode: 0:disable 1:enable |
| 1.3.6.1.4.1.4756.20.390.20.1.12 | Columnf1000DSFx1Link | read-only | current | FRM220-f1000DS card fiber1 link: 0:down 1:up |
| 1.3.6.1.4.1.4756.20.390.20.1.13 | Columnf1000DSFx1RxAct | read-write | current | FRM220-f1000DS card fiber1 Rx Active: 0:Normal 1:Disable |
| 1.3.6.1.4.1.4756.20.390.20.1.14 | Columnf1000DSFx1Speed | read-write | current | FRM220-f1000DS card fiber1 Speed: 0:Reduced_Bandwidth 1:Full_Bandwidth |
| 1.3.6.1.4.1.4756.20.390.20.1.15 | Columnf1000DSFx1TxFail | read-only | current | FRM220-f1000DS card fiber1 Tx Fail: 0:Normal 1:Fail |
| 1.3.6.1.4.1.4756.20.390.20.1.16 | Columnf1000DSFx1AlsMode | read-write | current | FRM220-f1000DS card fiber1 ALS Mode: 0:Disable 1:Enable |
| 1.3.6.1.4.1.4756.20.390.20.1.17 | Columnf1000DSFx2Link | read-only | current | FRM220-f1000DS card fiber2 link: 0:down 1:up |
| 1.3.6.1.4.1.4756.20.390.20.1.18 | Columnf1000DSFx2RxAct | read-write | current | FRM220-f1000DS card fiber2 Rx Active: 0:Normal 1:Disable |
| 1.3.6.1.4.1.4756.20.390.20.1.19 | Columnf1000DSFx2Speed | read-write | current | FRM220-f1000DS card fiber2 Speed: 0:Reduced_Bandwidth 1:Full_Bandwidth |
| 1.3.6.1.4.1.4756.20.390.20.1.20 | Columnf1000DSFx2TxFail | read-only | current | FRM220-f1000DS card fiber2 Tx Fail: 0:Normal 1:Fail |
| 1.3.6.1.4.1.4756.20.390.20.1.21 | Columnf1000DSFx2AlsMode | read-write | current | FRM220-f1000DS card fiber2 ALS Mode: 0:Disable 1:Enable |
| 1.3.6.1.4.1.4756.20.390.20.1.22 | Columnf1000DSFx1DD | read-only | current | FRM220-f1000DS card fiber1 Digital Diagnostic function: 0:yes 1:no |
| 1.3.6.1.4.1.4756.20.390.20.1.23 | Columnf1000DSFx1DDVendor | read-only | current | FRM220-f1000DS card fiber1 D/D information: Vendor name |
| 1.3.6.1.4.1.4756.20.390.20.1.24 | Columnf1000DSFx1DDPartNo | read-only | current | FRM220-f1000DS card fiber1 D/D information: Vendor part number |
| 1.3.6.1.4.1.4756.20.390.20.1.25 | Columnf1000DSFx1DDFiberType | read-only | current | FRM220-f1000DS card fiber1 D/D information: Fiber Type |
| 1.3.6.1.4.1.4756.20.390.20.1.26 | Columnf1000DSFx1DDWaveLen1 | read-only | current | FRM220-f1000DS card fiber1 D/D information: Wave length 1 |
| 1.3.6.1.4.1.4756.20.390.20.1.27 | Columnf1000DSFx1DDWaveLen2 | read-only | current | FRM220-f1000DS card fiber1 D/D information: Wave length 2 |
| 1.3.6.1.4.1.4756.20.390.20.1.28 | Columnf1000DSFx1DDLinkLen | read-only | current | FRM220-f1000DS card fiber1 D/D information: Link length |
| 1.3.6.1.4.1.4756.20.390.20.1.29 | Columnf1000DSFx1DDLenUnit | read-only | current | FRM220-f1000DS card fiber1 D/D information: Length Unit |
| 1.3.6.1.4.1.4756.20.390.20.1.30 | Columnf1000DSFx1DDStatus | read-only | current | FRM220-f1000DS card fiber1 D/D information: Status Support |
| 1.3.6.1.4.1.4756.20.390.20.1.31 | Columnf1000DSFx1DDRxSens | read-only | current | FRM220-f1000DS card fiber1 D/D information: Rx Sensitivity |
| 1.3.6.1.4.1.4756.20.390.20.1.32 | Columnf1000DSFx1DDTxPwr | read-only | current | FRM220-f1000DS card fiber1 D/D information: Tx power |
| 1.3.6.1.4.1.4756.20.390.20.1.33 | Columnf1000DSFx1DDRxPwr | read-only | current | FRM220-f1000DS card fiber1 D/D information: Rx power |
| 1.3.6.1.4.1.4756.20.390.20.1.34 | Columnf1000DSFx1DDTemp | read-only | current | FRM220-f1000DS card fiber1 D/D information: Temperature in degree C |
| 1.3.6.1.4.1.4756.20.390.20.1.35 | Columnf1000DSFx1DDPwrMargin | read-only | current | FRM220-f1000DS card fiber1 D/D information: Power margin |
| 1.3.6.1.4.1.4756.20.390.20.1.36 | Columnf1000DSFx1DDPwrLoss | read-only | current | FRM220-f1000DS card fiber1 D/D information: Power loss |
| 1.3.6.1.4.1.4756.20.390.20.1.37 | Columnf1000DSFx2DD | read-only | current | FRM220-f1000DS card fiber2 Digital Diagnostic function: 0:yes 1:no |
| 1.3.6.1.4.1.4756.20.390.20.1.38 | Columnf1000DSFx2DDVendor | read-only | current | FRM220-f1000DS card fiber2 D/D information: Vendor name |
| 1.3.6.1.4.1.4756.20.390.20.1.39 | Columnf1000DSFx2DDPartNo | read-only | current | FRM220-f1000DS card fiber2 D/D information: Vendor part number |
| 1.3.6.1.4.1.4756.20.390.20.1.40 | Columnf1000DSFx2DDFiberType | read-only | current | FRM220-f1000DS card fiber2 D/D information: Fiber Type |
| 1.3.6.1.4.1.4756.20.390.20.1.41 | Columnf1000DSFx2DDWaveLen1 | read-only | current | FRM220-f1000DS card fiber2 D/D information: Wave length 1 |
| 1.3.6.1.4.1.4756.20.390.20.1.42 | Columnf1000DSFx2DDWaveLen2 | read-only | current | FRM220-f1000DS card fiber2 D/D information: Wave length 2 |
| 1.3.6.1.4.1.4756.20.390.20.1.43 | Columnf1000DSFx2DDLinkLen | read-only | current | FRM220-f1000DS card fiber2 D/D information: Link length |
| 1.3.6.1.4.1.4756.20.390.20.1.44 | Columnf1000DSFx2DDLenUnit | read-only | current | FRM220-f1000DS card fiber2 D/D information: Length Unit |
| 1.3.6.1.4.1.4756.20.390.20.1.45 | Columnf1000DSFx2DDStatus | read-only | current | FRM220-f1000DS card fiber2 D/D information: Status Support |
| 1.3.6.1.4.1.4756.20.390.20.1.46 | Columnf1000DSFx2DDRxSens | read-only | current | FRM220-f1000DS card fiber2 D/D information: Rx Sensitivity |
| 1.3.6.1.4.1.4756.20.390.20.1.47 | Columnf1000DSFx2DDTxPwr | read-only | current | FRM220-f1000DS card fiber2 D/D information: Tx power |
| 1.3.6.1.4.1.4756.20.390.20.1.48 | Columnf1000DSFx2DDRxPwr | read-only | current | FRM220-f1000DS card fiber2 D/D information: Rx power |
| 1.3.6.1.4.1.4756.20.390.20.1.49 | Columnf1000DSFx2DDTemp | read-only | current | FRM220-f1000DS card fiber2 D/D information: Temperature in degree C |
| 1.3.6.1.4.1.4756.20.390.20.1.50 | Columnf1000DSFx2DDPwrMargin | read-only | current | FRM220-f1000DS card fiber2 D/D information: Power margin |
| 1.3.6.1.4.1.4756.20.390.20.1.51 | Columnf1000DSFx2DDPwrLoss | read-only | current | FRM220-f1000DS card fiber2 D/D information: Power loss |
| 1.3.6.1.4.1.4756.20.391 | NodeprotectionCards | |||
| 1.3.6.1.4.1.4756.20.391.20 | TableprotectionTable | not-accessible | current | A list of FRM220-protection card entries. |
| 1.3.6.1.4.1.4756.20.391.20.1 | RowprotectionEntry | not-accessible | current | An entry containing management information applicable to a particular FRM220-protection card. |
| 1.3.6.1.4.1.4756.20.391.20.1.1 | ColumnprotectionChassisIndex | read-only | current | A unique value for each local card. It is the chassis location number. |
| 1.3.6.1.4.1.4756.20.391.20.1.2 | ColumnprotectionSlotIndex | read-only | current | A unique value for each local card. It is the slot location number. |
| 1.3.6.1.4.1.4756.20.391.20.1.3 | ColumnprotectionCardHWVer | read-only | current | FRM220-protection card hardware version x.xxx |
| 1.3.6.1.4.1.4756.20.391.20.1.4 | ColumnprotectionCardFWVer | read-only | current | FRM220-protection card firmware version x.xxx |
| 1.3.6.1.4.1.4756.20.391.20.1.5 | ColumnprotectionCardCPLDVer | read-only | current | FRM220-protection card CPLD version x.xxx |
| 1.3.6.1.4.1.4756.20.391.20.1.6 | ColumnprotectionCardFPGAVer | read-only | current | FRM220-protection card FPGA version x.xxx |
| 1.3.6.1.4.1.4756.20.391.20.1.7 | ColumnprotectionPortActive | read-write | current | FRM220-protection card port active: 0:Disable 1:Enable |
| 1.3.6.1.4.1.4756.20.391.20.1.8 | ColumnprotectionPortReset | read-write | current | Force FRM220-protection card reset mode: 0:Off 1:Action |
| 1.3.6.1.4.1.4756.20.391.20.1.9 | ColumnprotectionSetDefault | read-write | current | FRM220- protection card protection set to default: 0:Off 1:Action |
| 1.3.6.1.4.1.4756.20.391.20.1.10 | ColumnprotectionSecondaryPathSignalLED | read-only | current | FRM220- protection card Secondary Path Signal LED: 0:off 1:on |
| 1.3.6.1.4.1.4756.20.391.20.1.11 | ColumnprotectionWorkingOnSecondaryPathLED | read-only | current | FRM220- protection card Working On Secondary Path LED: 0:off 1:on |
| 1.3.6.1.4.1.4756.20.391.20.1.12 | ColumnprotectionPrimaryPathSignalLED | read-only | current | FRM220- protection card Primary Path Signal LED: 0:off 1:on |
| 1.3.6.1.4.1.4756.20.391.20.1.13 | ColumnprotectionWorkingOnPrimaryPathLED | read-only | current | FRM220- protection card Working On Primary Path LED: 0:off 1:on |
| 1.3.6.1.4.1.4756.20.391.20.1.14 | ColumnprotectionPowerLED | read-only | current | FRM220- protection card Power LED: 0:off 1:on |
| 1.3.6.1.4.1.4756.20.391.20.1.15 | ColumnprotectionSystemOkLED | read-only | current | FRM220- protection card System Ok LED: 0:off 1:on |
| 1.3.6.1.4.1.4756.20.391.20.1.16 | ColumnprotectionWorkingMode | read-write | current | FRM220- protection card Working Mode: 0:Type1:Non-Revertive Type2:Non-Revertive 1:Type1:Revertive Type2:Non-Revertive 2:Type1:Primary Type2:Primary 3:Type1:Sec… |
| 1.3.6.1.4.1.4756.20.391.20.1.17 | ColumnprotectionWorkingPath | read-only | current | FRM220- protection card Working Path: 0:Primary 1:Secondary |
| 1.3.6.1.4.1.4756.20.391.20.1.18 | ColumnprotectionPrimarySignal | read-only | current | FRM220- protection card Primary Signal: 0:Loss 1:Normal |
| 1.3.6.1.4.1.4756.20.391.20.1.19 | ColumnprotectionSecondarySignal | read-only | current | FRM220- protection card Secondary Signal: 0:Loss 1:Normal |
| 1.3.6.1.4.1.4756.20.391.20.1.20 | ColumnprotectionPrimaryDetectLevel | read-write | current | FRM220- protection card Primary Detect Level: 0:-35dB 1:-33dB 2:-31dB 3:-29dB 4:-27dB 5:-25dB 6:-23dB 7:-21dB 8:-19dB 9:-17dB 10:-15dB 11:-13dB 12:-11dB 13:-9d… |
| 1.3.6.1.4.1.4756.20.391.20.1.21 | ColumnprotectionPrimaryPowerSign | read-only | current | FRM220- protection card Primary Power Sign: 0:Postive 1:Negativ |
| 1.3.6.1.4.1.4756.20.391.20.1.22 | ColumnprotectionPrimaryPower | read-only | current | FRM220- protection card Primary Power |
| 1.3.6.1.4.1.4756.20.391.20.1.23 | ColumnprotectionSecondaryDetectLevel | read-write | current | FRM220- protection card Secondary Detect Level: 0:-35dB 1:-33dB 2:-31dB 3:-29dB 4:-27dB 5:-25dB 6:-23dB 7:-21dB 8:-19dB 9:-17dB 10:-15dB 11:-13dB 12:-11dB 13:-… |
| 1.3.6.1.4.1.4756.20.391.20.1.24 | ColumnprotectionSecondaryPowerSign | read-only | current | FRM220- protection card Secondary Power Sign: 0:Positive 1:Negative |
| 1.3.6.1.4.1.4756.20.391.20.1.25 | ColumnprotectionSecondaryPower | read-only | current | FRM220- protection card Secondary Power |
| 1.3.6.1.4.1.4756.20.391.20.1.26 | ColumnprotectionChangeTime | read-write | current | FRM220-protection card change time, only support OPS51 and OPS51M. 0:5sec 1:10sec 2:20sec 3:30sec 4:60sec 5:120sec 6:240sec 7:480sec 8:Not Support |
| 1.3.6.1.4.1.4756.20.391.20.1.27 | ColumnprotectionType | read-only | current | FRM220-protection card type 0:frm220-ops52 1:frm220-ops51 2:frm220-ops52p 3:frm220-ops51m |
| 1.3.6.1.4.1.4756.20.391.20.1.28 | ColumnprotectionTransitionDelayTime | read-write | current | Local Frm220 protection Transition Delay Time (Unit is ms) |
| 1.3.6.1.4.1.4756.20.400 | Nodefdse3LocalCards | |||
| 1.3.6.1.4.1.4756.20.400.20 | TablefDS3E3LocalTable | not-accessible | current | A list of local FRM220-DS3/E3 card entries. The number of entries is fDS3/E3-No-L. |
| 1.3.6.1.4.1.4756.20.400.20.1 | RowfDS3E3LocalEntry | not-accessible | current | An entry containing management information applicable to a particular local FRM220-DS3/E3 card. |
| 1.3.6.1.4.1.4756.20.400.20.1.1 | ColumnfDS3E3ChassisIndexLocal | read-only | current | A unique value for each local card. It is the chassis location number. |
| 1.3.6.1.4.1.4756.20.400.20.1.2 | ColumnfDS3E3SlotIndexLocal | read-only | current | A unique value for each local card. It is the slot location number. |
| 1.3.6.1.4.1.4756.20.400.20.1.3 | ColumnfDS3E3CardHWVerLocal | read-only | current | Local FRM220-DS3/E3 card hardware version x.xxx |
| 1.3.6.1.4.1.4756.20.400.20.1.4 | ColumnfDS3E3CardFWVerLocal | read-only | current | Local FRM220-DS3/E3 card firmware version x.xxx |
| 1.3.6.1.4.1.4756.20.400.20.1.5 | ColumnfDS3E3CardCPLDVerLocal | read-only | current | Local FRM220-DS3/E3 card CPLD version x.xxx |
| 1.3.6.1.4.1.4756.20.400.20.1.6 | ColumnfDS3E3CardFPGAVerLocal | read-only | current | Local FRM220-DS3/E3 card FPGA version x.xxx |
| 1.3.6.1.4.1.4756.20.400.20.1.7 | ColumnfDS3E3DeviceActiveLocal | read-write | current | Devie Active: 0:Disable 1:Enable |
| 1.3.6.1.4.1.4756.20.400.20.1.8 | ColumnfDS3E3PortResetLocal | read-write | current | Local FRM220-DS3/E3 card port reset: 0:OFF 1:ACTION |
| 1.3.6.1.4.1.4756.20.400.20.1.9 | ColumnfDS3E3SetDefaultLocal | read-write | current | Local FRM220-DS3/E3 card set to default: 0:OFF 1:ACTION |
| 1.3.6.1.4.1.4756.20.400.20.1.10 | ColumnfDS3E3CoaxLinkLocal | read-only | current | Local FRM220-DS3/E3 card Coax link status: 0:OFF 1:ON |
| 1.3.6.1.4.1.4756.20.400.20.1.11 | ColumnfDS3E3CoaxRxAISLocal | read-only | current | Local FRM220-DS3/E3 card Coax Rx AIS status: 0:OFF 1:ON |
| 1.3.6.1.4.1.4756.20.400.20.1.12 | ColumnfDS3E3CoaxTrnasmitLocal | read-only | current | Local FRM220-DS3/E3 card Coax Transit status: 0:Normal 1:Failure |
| 1.3.6.1.4.1.4756.20.400.20.1.13 | ColumnfDS3E3CoaxModeTypeLocal | read-write | current | Local FRM220-DS3/E3 card Coax Mode Type: 0:DS3 1:STS-1 2:E3 |
| 1.3.6.1.4.1.4756.20.400.20.1.14 | ColumnfDS3E3CoaxTxAISLocal | read-write | current | Local FRM220-DS3/E3 card Coax Tx AIS: 0:Disbale 1:Enable |
| 1.3.6.1.4.1.4756.20.400.20.1.15 | ColumnfDS3E3Fx1LinkLocal | read-only | current | Local FRM220-DS3/E3 Fiber1 link status: 0:Down 1:Up |
| 1.3.6.1.4.1.4756.20.400.20.1.16 | ColumnfDS3E3Fx1FEFLocal | read-only | current | Local FRM220-DS3/E3 Fiber1 EFE status: 0:OFF 1:ON |
| 1.3.6.1.4.1.4756.20.400.20.1.17 | ColumnfDS3E3Fx1ALSLocal | read-write | current | Local FRM220-DS3/E3 Fiber1 Auto Laser Shutdown: 0:Disable 1:Enable |
| 1.3.6.1.4.1.4756.20.400.20.1.18 | ColumnfDS3E3Fx1DDLocal | read-only | current | Local FRM220-DS3/E3 card fiber Digital Diagnostic function: 0:No 1:Yes |
| 1.3.6.1.4.1.4756.20.400.20.1.19 | ColumnfDS3E3Fx1DDVendorLocal | read-only | current | Local FRM220-DS3/E3 card fiber D/D information: Vendor name |
| 1.3.6.1.4.1.4756.20.400.20.1.20 | ColumnfDS3E3Fx1DDPartNoLocal | read-only | current | Local FRM220-DS3/E3 card fiber D/D information: Vendor part number |
| 1.3.6.1.4.1.4756.20.400.20.1.21 | ColumnfDS3E3Fx1DDFiberTypeLocal | read-only | current | Local FRM220-DS3/E3 card fiber D/D information: Fiber Type |
| 1.3.6.1.4.1.4756.20.400.20.1.22 | ColumnfDS3E3Fx1DDWaveLenLocal | read-only | current | Local FRM220-DS3/E3 card fiber D/D information: Wave length |
| 1.3.6.1.4.1.4756.20.400.20.1.23 | ColumnfDS3E3Fx1DDWaveLen2Local | read-only | current | Local FRM220-DS3/E3 card fiber D/D information: Wave length 2 |
| 1.3.6.1.4.1.4756.20.400.20.1.24 | ColumnfDS3E3Fx1DDLinkLenLocal | read-only | current | Local FRM220-DS3/E3 card fiber D/D information: Link length |
| 1.3.6.1.4.1.4756.20.400.20.1.25 | ColumnfDS3E3Fx1DDLenUnitLocal | read-only | current | Local FRM220-DS3/E3 card fiber D/D information: Length Unit |
| 1.3.6.1.4.1.4756.20.400.20.1.26 | ColumnfDS3E3Fx1DDStatusLocal | read-only | current | Local FRM220-DS3/E3 card fiber D/D information: Status Support |
| 1.3.6.1.4.1.4756.20.400.20.1.27 | ColumnfDS3E3Fx1DDRxSensLocal | read-only | current | Local FRM220-DS3/E3 card fiber D/D information: Rx Sensitivity |
| 1.3.6.1.4.1.4756.20.400.20.1.28 | ColumnfDS3E3Fx1DDTxPWRLocal | read-only | current | Local FRM220-DS3/E3 card fiber D/D information: Tx power |
| 1.3.6.1.4.1.4756.20.400.20.1.29 | ColumnfDS3E3Fx1DDRxPWRLocal | read-only | current | Local FRM220-DS3/E3 card fiber D/D information: Rx power |
| 1.3.6.1.4.1.4756.20.400.20.1.30 | ColumnfDS3E3Fx1DDTempLocal | read-only | current | Local FRM220-DS3/E3 card fiber D/D information: Temperature in degree C |
| 1.3.6.1.4.1.4756.20.400.20.1.31 | ColumnfDS3E3Fx1DDPWRMarginLocal | read-only | current | Local FRM220-DS3/E3 card fiber D/D information: Power margin |
| 1.3.6.1.4.1.4756.20.400.20.1.32 | ColumnfDS3E3LoopBackSelectLocal | read-write | current | Local FRM220-DS3/E3 card LoopBack select side: 0:Fiber side 1:Coax side |
| 1.3.6.1.4.1.4756.20.400.20.1.33 | ColumnfDS3E3LoopBackFunLocal | read-write | current | Local FRM220-DS3/E3 card LoopBack function: 0:OFF 1:LLB 2:RLB 3:RRLB |
| 1.3.6.1.4.1.4756.20.400.20.1.34 | ColumnfDS3E3ESCounterLocal | read-only | current | Local FRM220-DS3/E3 card Performance: ES Counter |
| 1.3.6.1.4.1.4756.20.400.20.1.35 | ColumnfDS3E3CoaxESCounterLocal | read-only | current | Local FRM220-DS3/E3 card Performance: Coax ES Counter |
| 1.3.6.1.4.1.4756.20.400.20.1.36 | ColumnfDS3E3FxESCounterLocal | read-only | current | Local FRM220-DS3/E3 card Performance: Fx ES Counter |
| 1.3.6.1.4.1.4756.20.400.20.1.37 | ColumnfDS3E3ClearESCounterLocal | read-write | current | Local FRM220-DS3/E3 card Clear ES Counter: 0:OFF 1:ACTION |
| 1.3.6.1.4.1.4756.20.400.20.1.38 | ColumnfDS3E3FxBitCounterLocal | read-only | current | Local FRM220-DS3/E3 card Performance: Fx Bit Counter |
| 1.3.6.1.4.1.4756.20.400.20.1.39 | ColumnfDS3E3ClearFxBitCounterLocal | read-write | current | Local FRM220-DS3/E3 card Clear Fx Bit Counter: 0:OFF 1:ACTION |
| 1.3.6.1.4.1.4756.20.400.20.1.40 | ColumnfDS3E3FxInsert1ErrorBitLocal | read-write | current | Local FRM220-DS3/E3 card Fx Inser one error Bit: 0:Normal 1:Insert |
| 1.3.6.1.4.1.4756.20.400.20.1.41 | ColumnfDS3E3CoaxBitCounterLocal | read-only | current | Local FRM220-DS3/E3 card Performance: Coax Bit Counter |
| 1.3.6.1.4.1.4756.20.400.20.1.42 | ColumnfDS3E3ClearCoaxBitCounterLocal | read-write | current | Local FRM220-DS3/E3 card Clear Coax Bit Counter: 0:OFF 1:ACTION |
| 1.3.6.1.4.1.4756.20.400.20.1.43 | ColumnfDS3E3PRBSLocal | read-write | current | Local FRM220-DS3/E3 card PRBS: 0:disable 1:Enable |
| 1.3.6.1.4.1.4756.20.400.20.1.44 | ColumnfDS3E3CoaxInsert1ErrorBitLocal | read-write | current | Local FRM220-DS3/E3 card Coax Insert One Error Bit: 0:Normal 1:Insert |
| 1.3.6.1.4.1.4756.20.400.20.1.45 | ColumnfDS3E3systemstatusLocal | read-only | current | Local FRM220-DS3/E3 System Status: 0:OFF 1:On |
| 1.3.6.1.4.1.4756.20.401 | Nodefdse3RemoteCards | |||
| 1.3.6.1.4.1.4756.20.401.20 | TablefDS3E3RemoteTable | not-accessible | current | A list of Remote FRM220-DS3/E3 card entries. The number of entries is fDS3/E3-No-L. |
| 1.3.6.1.4.1.4756.20.401.20.1 | RowfDS3E3RemoteEntry | not-accessible | current | An entry containing management information applicable to a particular Remote FRM220-DS3/E3 card. |
| 1.3.6.1.4.1.4756.20.401.20.1.1 | ColumnfDS3E3ChassisIndexRemote | read-only | current | A unique value for each Remote card. It is the chassis location number. |
| 1.3.6.1.4.1.4756.20.401.20.1.2 | ColumnfDS3E3SlotIndexRemote | read-only | current | A unique value for each Remote card. It is the slot location number. |
| 1.3.6.1.4.1.4756.20.401.20.1.3 | ColumnfDS3E3CardHWVerRemote | read-only | current | Remote FRM220-DS3/E3 card hardware version x.xxx |
| 1.3.6.1.4.1.4756.20.401.20.1.4 | ColumnfDS3E3CardFWVerRemote | read-only | current | Remote FRM220-DS3/E3 card firmware version x.xxx |
| 1.3.6.1.4.1.4756.20.401.20.1.5 | ColumnfDS3E3CardCPLDVerRemote | read-only | current | Remote FRM220-DS3/E3 card CPLD version x.xxx |
| 1.3.6.1.4.1.4756.20.401.20.1.6 | ColumnfDS3E3CardFPGAVerRemote | read-only | current | Remote FRM220-DS3/E3 card FPGA version x.xxx |
| 1.3.6.1.4.1.4756.20.401.20.1.7 | ColumnfDS3E3PortResetRemote | read-write | current | Remote FRM220-DS3/E3 card port reset: 0:OFF 1:ACTION |
| 1.3.6.1.4.1.4756.20.401.20.1.8 | ColumnfDS3E3SetDefaultRemote | read-write | current | Remote FRM220-DS3/E3 card set to default: 0:OFF 1:ACTION |
| 1.3.6.1.4.1.4756.20.401.20.1.9 | ColumnfDS3E3CoaxLinkRemote | read-only | current | Remote FRM220-DS3/E3 card Coax link status: 0:OFF 1:ON |
| 1.3.6.1.4.1.4756.20.401.20.1.10 | ColumnfDS3E3CoaxRxAISRemote | read-only | current | Remote FRM220-DS3/E3 card Coax Rx AIS status: 0:OFF 1:ON |
| 1.3.6.1.4.1.4756.20.401.20.1.11 | ColumnfDS3E3CoaxTrnasmitRemote | read-only | current | Remote FRM220-DS3/E3 card Coax Transit status: 0:Normal 1:Failure |
| 1.3.6.1.4.1.4756.20.401.20.1.12 | ColumnfDS3E3CoaxModeTypeRemote | read-write | current | Remote FRM220-DS3/E3 card Coax Mode Type: 0:DS3 1:STS-1 2:E3 |
| 1.3.6.1.4.1.4756.20.401.20.1.13 | ColumnfDS3E3CoaxTxAISRemote | read-write | current | Remote FRM220-DS3/E3 card Coax Tx AIS: 0:Disbale 1:Enable |
| 1.3.6.1.4.1.4756.20.401.20.1.14 | ColumnfDS3E3Fx1LinkRemote | read-only | current | Remote FRM220-DS3/E3 Fiber1 link status: 0:Down 1:Up |
| 1.3.6.1.4.1.4756.20.401.20.1.15 | ColumnfDS3E3Fx1FEFRemote | read-only | current | Remote FRM220-DS3/E3 Fiber1 EFE status: 0:OFF 1:ON |
| 1.3.6.1.4.1.4756.20.401.20.1.16 | ColumnfDS3E3Fx1ALSRemote | read-write | current | Remote FRM220-DS3/E3 Fiber1 Auto Laser Shutdown: 0:Disable 1:Enable |
| 1.3.6.1.4.1.4756.20.401.20.1.17 | ColumnfDS3E3Fx1DDRemote | read-only | current | Remote FRM220-DS3/E3 card fiber Digital Diagnostic function: 0:No 1:Yes |
| 1.3.6.1.4.1.4756.20.401.20.1.18 | ColumnfDS3E3Fx1DDVendorRemote | read-only | current | Remote FRM220-DS3/E3 card fiber D/D information: Vendor name |
| 1.3.6.1.4.1.4756.20.401.20.1.19 | ColumnfDS3E3Fx1DDPartNoRemote | read-only | current | Remote FRM220-DS3/E3 card fiber D/D information: Vendor part number |
| 1.3.6.1.4.1.4756.20.401.20.1.20 | ColumnfDS3E3Fx1DDFiberTypeRemote | read-only | current | Remote FRM220-DS3/E3 card fiber D/D information: Fiber Type |
| 1.3.6.1.4.1.4756.20.401.20.1.21 | ColumnfDS3E3Fx1DDWaveLenRemote | read-only | current | Remote FRM220-DS3/E3 card fiber D/D information: Wave length |
| 1.3.6.1.4.1.4756.20.401.20.1.22 | ColumnfDS3E3Fx1DDWaveLen2Remote | read-only | current | Remote FRM220-DS3/E3 card fiber D/D information: Wave length 2 |
| 1.3.6.1.4.1.4756.20.401.20.1.23 | ColumnfDS3E3Fx1DDLinkLenRemote | read-only | current | Remote FRM220-DS3/E3 card fiber D/D information: Link length |
| 1.3.6.1.4.1.4756.20.401.20.1.24 | ColumnfDS3E3Fx1DDLenUnitRemote | read-only | current | Remote FRM220-DS3/E3 card fiber D/D information: Length Unit |
| 1.3.6.1.4.1.4756.20.401.20.1.25 | ColumnfDS3E3Fx1DDStatusRemote | read-only | current | Remote FRM220-DS3/E3 card fiber D/D information: Status Support |
| 1.3.6.1.4.1.4756.20.401.20.1.26 | ColumnfDS3E3Fx1DDRxSensRemote | read-only | current | Remote FRM220-DS3/E3 card fiber D/D information: Rx Sensitivity |
| 1.3.6.1.4.1.4756.20.401.20.1.27 | ColumnfDS3E3Fx1DDTxPWRRemote | read-only | current | Remote FRM220-DS3/E3 card fiber D/D information: Tx power |
| 1.3.6.1.4.1.4756.20.401.20.1.28 | ColumnfDS3E3Fx1DDRxPWRRemote | read-only | current | Remote FRM220-DS3/E3 card fiber D/D information: Rx power |
| 1.3.6.1.4.1.4756.20.401.20.1.29 | ColumnfDS3E3Fx1DDTempRemote | read-only | current | Remote FRM220-DS3/E3 card fiber D/D information: Temperature in degree C |
| 1.3.6.1.4.1.4756.20.401.20.1.30 | ColumnfDS3E3Fx1DDPWRMarginRemote | read-only | current | Remote FRM220-DS3/E3 card fiber D/D information: Power margin |
| 1.3.6.1.4.1.4756.20.401.20.1.31 | ColumnfDS3E3LoopBackFunRemote | read-write | current | Remote FRM220-DS3/E3 card LoopBack function(Coax Only): 0:OFF 1:LLB 2:RLB |
| 1.3.6.1.4.1.4756.20.401.20.1.32 | ColumnfDS3E3ESCounterRemote | read-only | current | Remote FRM220-DS3/E3 card Performance: ES Counter |
| 1.3.6.1.4.1.4756.20.401.20.1.33 | ColumnfDS3E3CoaxESCounterRemote | read-only | current | Remote FRM220-DS3/E3 card Performance: Coax ES Counter |
| 1.3.6.1.4.1.4756.20.401.20.1.34 | ColumnfDS3E3FxESCounterRemote | read-only | current | Remote FRM220-DS3/E3 card Performance: Fx ES Counter |
| 1.3.6.1.4.1.4756.20.401.20.1.35 | ColumnfDS3E3ClearESCounterRemote | read-write | current | Remote FRM220-DS3/E3 card Clear ES Counter: 0:OFF 1:ACTION |
| 1.3.6.1.4.1.4756.20.401.20.1.36 | ColumnfDS3E3FxBitCounterRemote | read-only | current | Remote FRM220-DS3/E3 card Performance: Fx Bit Counter |
| 1.3.6.1.4.1.4756.20.401.20.1.37 | ColumnfDS3E3ClearFxBitCounterRemote | read-write | current | Remote FRM220-DS3/E3 card Clear Fx Bit Counter: 0:OFF 1:ACTION |
| 1.3.6.1.4.1.4756.20.401.20.1.38 | ColumnfDS3E3FxInsert1ErrorBitRemote | read-write | current | Remote FRM220-DS3/E3 card Fx Insert One Error Bit: 0:Normal 1:Insert |
| 1.3.6.1.4.1.4756.20.401.20.1.39 | ColumnfDS3E3CoaxBitCounterRemote | read-only | current | Remote FRM220-DS3/E3 card Performance: Coax Bit Counter |
| 1.3.6.1.4.1.4756.20.401.20.1.40 | ColumnfDS3E3ClearCoaxBitCounterRemote | read-write | current | Remote FRM220-DS3/E3 card Clear Coax Bit Counter: 0:OFF 1:ACTION |
| 1.3.6.1.4.1.4756.20.401.20.1.41 | ColumnfDS3E3PRBSRemote | read-write | current | Remote FRM220-DS3/E3 card PRBS: 0:Disable 1:Enable |
| 1.3.6.1.4.1.4756.20.401.20.1.42 | ColumnfDS3E3CoaxInsert1ErrorBitRemote | read-write | current | Remote FRM220-DS3/E3 card Coax Insert One Error Bit: 0:Normal 1:Insert |
| 1.3.6.1.4.1.4756.20.401.20.1.43 | ColumnfDS3E3systemstatusRemote | read-only | current | Remote FRM220-DS3/E3 System Status: 0:OFF 1:ON |
| 1.3.6.1.4.1.4756.20.410 | Nodef1000EASX1LocalCards | |||
| 1.3.6.1.4.1.4756.20.410.40 | Tablef1000EASX1LocalTable | not-accessible | current | A list of local 1000EAS/X card entries. |
| 1.3.6.1.4.1.4756.20.410.40.1 | Rowf1000EASX1LocalEntry | not-accessible | current | An entry containing management information applicable to a particular local f1000EASX card. |
| 1.3.6.1.4.1.4756.20.410.40.1.1 | Columnf1000EASX1ChassisIndexLocal | read-only | current | A unique value for each chassis ID. For CH20, it is the chassis ID. For CH08, it is always 0. |
| 1.3.6.1.4.1.4756.20.410.40.1.2 | Columnf1000EASX1SlotIndexLocal | read-only | current | A unique value for each local card. It is the slot location number. |
| 1.3.6.1.4.1.4756.20.410.40.1.3 | Columnf1000EASX1CardHWVerLocal | read-only | current | Local device card hardware version x.xxx |
| 1.3.6.1.4.1.4756.20.410.40.1.4 | Columnf1000EASX1CardFWVerLocal | read-only | current | Local device card firmware version x.xxx |
| 1.3.6.1.4.1.4756.20.410.40.1.5 | Columnf1000EASX1CardCPLDVerLocal | read-only | current | Local device card CPLD version x.xxx |
| 1.3.6.1.4.1.4756.20.410.40.1.6 | Columnf1000EASX1CardFPGAVerLocal | read-only | current | Local device card FPGA version x.xxx |
| 1.3.6.1.4.1.4756.20.410.40.1.7 | Columnf1000EASX1ModelLocal | read-only | current | Local 1000EAS/X-1 Serial Type |
| 1.3.6.1.4.1.4756.20.410.40.1.8 | Columnf1000EASX1FiberLinkLocal | read-only | current | Local device card fiber port link status: 0:Down 1:Up |
| 1.3.6.1.4.1.4756.20.410.40.1.9 | Columnf1000EASX1FiberOAMLoopedLocal | read-only | current | Local device card fiber port OAM looped: 0:Off 1:on |
| 1.3.6.1.4.1.4756.20.410.40.1.10 | Columnf1000EASX1FiberLBTestLocal | read-write | current | Force remote device card to do fiber port LoopBack testing: 0:Off 1:Action |
| 1.3.6.1.4.1.4756.20.410.40.1.11 | Columnf1000EASX1FiberOAMRLBStatusLocal | read-only | current | Remote device card fiber port LoopBack testing status: 0:Off 1:Ok 2:Fail |
| 1.3.6.1.4.1.4756.20.410.40.1.12 | Columnf1000EASX1FiberRemoPwrAbLocal | read-only | current | Local device card fiber port 1 Remote Power status: 0:Abnormal 1:OK 2:None |
| 1.3.6.1.4.1.4756.20.410.40.1.13 | Columnf1000EASX1FiberFEFLocal | read-only | current | Local device card fiber port FEF status: 0:Off 1:Detected |
| 1.3.6.1.4.1.4756.20.410.40.1.14 | Columnf1000EASX1FiberIngressRateLocal | read-write | current | Local device card fiber Ingress Rate Limit: 0 = Unlimit input format: 64k(K),100m(M),100 If doesn't input the unit, the default was Mega. Limite Rate : 64K ~ 9… |
| 1.3.6.1.4.1.4756.20.410.40.1.15 | Columnf1000EASX1FiberEgressRateLocal | read-write | current | Local device card fiber Egress Rate Limit: 0 = Unlimit input format: 64k(K),100m(M),100 If doesn't input the unit, the default was Mega. Limite Rate : 64K ~ 99… |
| 1.3.6.1.4.1.4756.20.410.40.1.16 | Columnf1000EASX1UtpLinkLocal | read-only | current | Local device card UTP port link status: 0:Down 1:Up |
| 1.3.6.1.4.1.4756.20.410.40.1.17 | Columnf1000EASX1UtpNegoLocal | read-write | current | Local device card UTP port negotiation status: 0:Manual 1:Auto |
| 1.3.6.1.4.1.4756.20.410.40.1.18 | Columnf1000EASX1UtpSpeedLocal | read-write | current | Local device card UTP port speed setting: 0:10 Base-T 1:100 Base-TX 2:1000 Base-TX |
| 1.3.6.1.4.1.4756.20.410.40.1.19 | Columnf1000EASX1UtpDuplexLocal | read-write | current | Local device card UTP port duplex setting: 0:Half duplex mode 1:Full duplex mode |
| 1.3.6.1.4.1.4756.20.410.40.1.20 | Columnf1000EASX1UtpSpeedStatusLocal | read-only | current | Local device card UTP port speed status: 0:10 Base-T 1:100 Base-TX 2:1000 Base-TX |
| 1.3.6.1.4.1.4756.20.410.40.1.21 | Columnf1000EASX1UtpDuplexStatusLocal | read-only | current | Local device card UTP port duplex status: 0:Half duplex mode 1:Full duplex mode |
| 1.3.6.1.4.1.4756.20.410.40.1.22 | Columnf1000EASX1UtpIngressRateLocal | read-write | current | Local device card utp Ingress Rate Limit: 0 = Unlimit input format: 64k(K),100m(M),100 If doesn't input the unit, the default was Mega. Limite Rate : 64K ~ 990M |
| 1.3.6.1.4.1.4756.20.410.40.1.23 | Columnf1000EASX1UtpEgressRateLocal | read-write | current | Local device card utp Egress Rate Limit: 0 = Unlimit input format: 64k(K),100m(M),100 If doesn't input the unit, the default was Mega. Limite Rate : 64K ~ 990M |
| 1.3.6.1.4.1.4756.20.410.40.1.24 | Columnf1000EASX1DeviceActiveLocal | read-write | current | Local device card active mode: (It is read-only in remote device.) 0:Disable 1:Enable |
| 1.3.6.1.4.1.4756.20.410.40.1.25 | Columnf1000EASX1DeviceResetLocal | read-write | current | Force local device card to reset mode: 0:Off 1:Action |
| 1.3.6.1.4.1.4756.20.410.40.1.26 | Columnf1000EASX1FiberActiveLocal | read-write | current | Local device fiber port active mode: 0:Disable 1:Enable |
| 1.3.6.1.4.1.4756.20.410.40.1.27 | Columnf1000EASX1UtpActiveLocal | read-write | current | Local device UTP port active mode: 0:Disable 1:Enable |
| 1.3.6.1.4.1.4756.20.410.40.1.28 | Columnf1000EASX1OamChModeLocal | read-write | current | Local device OAM Channel mode: 0:Disable 1:passive 2:Active |
| 1.3.6.1.4.1.4756.20.410.40.1.29 | Columnf1000EASX1OamMaxPDUsLocal | read-write | current | Local device OAM max OAMPDU size: 60-1518 Octets |
| 1.3.6.1.4.1.4756.20.410.40.1.30 | Columnf1000EASX1FiberAlsLocal | read-write | current | Local device card port Auto Laser Shutdown mode: 0:Disable 1:Enable |
| 1.3.6.1.4.1.4756.20.410.40.1.31 | Columnf1000EASX1PauseFrameLocal | read-write | current | Local device card pause frame mode: 0:Disable 1:Enable |
| 1.3.6.1.4.1.4756.20.410.40.1.32 | Columnf1000EASX1SendFHRtoALocal | read-write | current | Local device card port send Fiber Hardware Reset to remote: 0:No action 1:Action |
| 1.3.6.1.4.1.4756.20.410.40.1.33 | Columnf1000EASX1FiberLLFDepPortLocal | read-write | current | Local device card port Link Loss Forwarding depends on port 3 Ethernet Rx link: 0:don't care 1:selected |
| 1.3.6.1.4.1.4756.20.410.40.1.34 | Columnf1000EASX1UtpLLFDepPortLocal | read-write | current | Local device card port Link Loss Forwarding depends on port Fiber Rx link: 0:don't care 1:selected |
| 1.3.6.1.4.1.4756.20.410.40.1.35 | Columnf1000EASX1AdvanceFunsLocal | read-write | current | Local device card Switch functions mode: 0:Normal 5:Static 802.1Q VLAN 6:Spanning Tree Protocol 7:802.1Q VLAN Trunk 9:Q in Q VLAN 11:Spanning Tree Protocol and… |
| 1.3.6.1.4.1.4756.20.410.40.1.36 | Columnf1000EASX1FiberInfoROM1Local | read-only | current | Local device card port INFORemoteOM information 1 valid: 0:Invalid 1:Valid |
| 1.3.6.1.4.1.4756.20.410.40.1.37 | Columnf1000EASX1FiberInfoROM2Local | read-only | current | Local device card port INFORemoteOM information 2 valid: 0:Invalid 1:Valid(replacing D/D function |
| 1.3.6.1.4.1.4756.20.410.40.1.38 | Columnf1000EASX1FiberInfoSN1Local | read-only | current | Local device card port 1 NFORemoteOM S/N 1 |
| 1.3.6.1.4.1.4756.20.410.40.1.39 | Columnf1000EASX1FiberInfoSN2Local | read-only | current | Local device card port 1 INFORemoteOM S/N 2 |
| 1.3.6.1.4.1.4756.20.410.40.1.40 | Columnf1000EASX1FiberDDLocal | read-only | current | Local device card fiber port Digital Diagnostic function: 0:No 1:Yes |
| 1.3.6.1.4.1.4756.20.410.40.1.41 | Columnf1000EASX1FiberDDVendorLocal | read-only | current | Local device card fiber port D/D information: Vendor name |
| 1.3.6.1.4.1.4756.20.410.40.1.42 | Columnf1000EASX1FiberDDPartNoLocal | read-only | current | Local device card fiber port D/D information: Vendor part number |
| 1.3.6.1.4.1.4756.20.410.40.1.43 | Columnf1000EASX1FiberDDVendorSNLocal | read-only | current | Local device card fiber port D/D information: Vendor Serial Number |
| 1.3.6.1.4.1.4756.20.410.40.1.44 | Columnf1000EASX1FiberDDFiberTypeLocal | read-only | current | Local device card fiber port D/D information: Fiber Type |
| 1.3.6.1.4.1.4756.20.410.40.1.45 | Columnf1000EASX1FiberDDWaveLenLocal | read-only | current | Local device card fiber port D/D information: Wave length |
| 1.3.6.1.4.1.4756.20.410.40.1.46 | Columnf1000EASX1FiberDDWaveLen2Local | read-only | current | Local device card fiber port D/D information: Wave length 2 |
| 1.3.6.1.4.1.4756.20.410.40.1.47 | Columnf1000EASX1FiberDDLinkLenLocal | read-only | current | Local device card fiber port D/D information: Link length |
| 1.3.6.1.4.1.4756.20.410.40.1.48 | Columnf1000EASX1FiberDDLenUnitLocal | read-only | current | Local device card fiber port D/D information: Length Unit |
| 1.3.6.1.4.1.4756.20.410.40.1.49 | Columnf1000EASX1FiberDDStatusLocal | read-only | current | Local device card fiber port D/D information: Status Support |
| 1.3.6.1.4.1.4756.20.410.40.1.50 | Columnf1000EASX1FiberDDRxSensLocal | read-only | current | Local device card fiber port D/D information: Rx Sensitivity |
| 1.3.6.1.4.1.4756.20.410.40.1.51 | Columnf1000EASX1FiberDDTxPWRLocal | read-only | current | Local device card fiber port D/D information: Tx power |
| 1.3.6.1.4.1.4756.20.410.40.1.52 | Columnf1000EASX1FiberDDRxPWRLocal | read-only | current | Local device card fiber port D/D information: Rx power |
| 1.3.6.1.4.1.4756.20.410.40.1.53 | Columnf1000EASX1FiberDDTempLocal | read-only | current | Local device card fiber port D/D information: Temperature in degree C |
| 1.3.6.1.4.1.4756.20.410.40.1.54 | Columnf1000EASX1FiberDDPWRMarginLocal | read-only | current | Local device card fiber port D/D information: Power margin |
| 1.3.6.1.4.1.4756.20.410.40.1.55 | Columnf1000EASX1FiberDDPWRLossLocal | read-only | current | Local device card fiber port D/D information: Power loss |
| 1.3.6.1.4.1.4756.20.410.40.1.56 | Columnf1000EASX1ClrRMONCntsLocal | read-write | current | Clear local device card RMON IN/OUT counters: 0:No action 1:Action |
| 1.3.6.1.4.1.4756.20.410.40.1.57 | Columnf1000EASX1FiberRMONInLocal | read-only | current | Local device card port RMON IN counter. |
| 1.3.6.1.4.1.4756.20.410.40.1.58 | Columnf1000EASX1FiberRMONOutLocal | read-only | current | Local device card port RMON OUT counter. |
| 1.3.6.1.4.1.4756.20.410.40.1.59 | Columnf1000EASX1UtpRMONInLocal | read-only | current | Local device card port RMON IN counter. |
| 1.3.6.1.4.1.4756.20.410.40.1.60 | Columnf1000EASX1UtpRMONOutLocal | read-only | current | Local device card port RMON OUT counter. |
| 1.3.6.1.4.1.4756.20.410.40.1.61 | Columnf1000EASX1ClrOAMCntsLocal | read-write | current | Clear local device card OAM counters: 0:No action 1:Action |
| 1.3.6.1.4.1.4756.20.410.40.1.62 | Columnf1000EASX1IpModeLocal | read-write | current | On Rack Ip Mode: 0:Enable 1:Disable |
| 1.3.6.1.4.1.4756.20.410.40.1.63 | Columnf1000EASX1OamChTxLocal | read-only | current | Local device OAM Channel TX OAMPDU frame count |
| 1.3.6.1.4.1.4756.20.410.40.1.64 | Columnf1000EASX1OamChRxLocal | read-only | current | Local device OAM Channel RX OAMPDU frame count |
| 1.3.6.1.4.1.4756.20.410.40.1.65 | Columnf1000EASX1OamInfoChTxLocal | read-only | current | Local device OAM Channel TX Information OAMPDU frame count |
| 1.3.6.1.4.1.4756.20.410.40.1.66 | Columnf1000EASX1OamInfoChRxLocal | read-only | current | Local device OAM Channel RX Information OAMPDU frame count |
| 1.3.6.1.4.1.4756.20.410.40.1.67 | Columnf1000EASX1OamEventChTxLocal | read-only | current | Local device OAM Channel TX Event OAMPDU frame count |
| 1.3.6.1.4.1.4756.20.410.40.1.68 | Columnf1000EASX1OamUniEvtChRxLocal | read-only | current | Local device OAM Channel RX Unique Event OAMPDU frame count |
| 1.3.6.1.4.1.4756.20.410.40.1.69 | Columnf1000EASX1OamDupEvtChRxLocal | read-only | current | Local device OAM Channel RX Duplicate Event OAMPDU frame count |
| 1.3.6.1.4.1.4756.20.410.40.1.70 | Columnf1000EASX1OamLbChTxLocal | read-only | current | Local device OAM Channel TX Loopback Control OAMPDU frame count |
| 1.3.6.1.4.1.4756.20.410.40.1.71 | Columnf1000EASX1OamLbChRxLocal | read-only | current | Local device OAM Channel RX Loopback Control OAMPDU frame count |
| 1.3.6.1.4.1.4756.20.410.40.1.72 | Columnf1000EASX1OamVarReqChTxLocal | read-only | current | Local device OAM Channel TX Variable Request OAMPDU frame count |
| 1.3.6.1.4.1.4756.20.410.40.1.73 | Columnf1000EASX1OamVarReqChRxLocal | read-only | current | Local device OAM Channel RX Variable Request OAMPDU frame count |
| 1.3.6.1.4.1.4756.20.410.40.1.74 | Columnf1000EASX1OamVarRspChTxLocal | read-only | current | Local device OAM Channel TX Variable Response OAMPDU frame count |
| 1.3.6.1.4.1.4756.20.410.40.1.75 | Columnf1000EASX1OamVarRspChRxLocal | read-only | current | Local device OAM Channel RX Variable Response OAMPDU frame count |
| 1.3.6.1.4.1.4756.20.410.40.1.76 | Columnf1000EASX1OamOuiChTxLocal | read-only | current | Local device OAM Channel TX OUI OAMPDU frame count |
| 1.3.6.1.4.1.4756.20.410.40.1.77 | Columnf1000EASX1OamOuiChRxLocal | read-only | current | Local device OAM Channel RX OUI OAMPDU frame count |
| 1.3.6.1.4.1.4756.20.410.40.1.78 | Columnf1000EASX1OamUnknowChRxLocal | read-only | current | Local device OAM Channel RX Unsupported OAMPDU frame count |
| 1.3.6.1.4.1.4756.20.410.40.1.79 | Columnf1000EASX1FiberSpeedLocal | read-write | current | Local device Fiber speed : 0:1000 1:100 |
| 1.3.6.1.4.1.4756.20.410.40.1.80 | Columnf1000EASX1MacLearningLocal | read-write | current | Local device Mac learning : 0:Disable 1:Enable |
| 1.3.6.1.4.1.4756.20.410.40.1.81 | Columnf1000EASX1Port1VIDLocal | read-write | current | Local device Port 1 VID : |
| 1.3.6.1.4.1.4756.20.410.40.1.82 | Columnf1000EASX1Port2VIDLocal | read-write | current | Local device Port 2 VID : |
| 1.3.6.1.4.1.4756.20.410.40.1.83 | Columnf1000EASX1Port1QinQLocal | read-write | current | Local device Port 1 Q in Q Support : 1:Disable 2:Enable |
| 1.3.6.1.4.1.4756.20.410.40.1.84 | Columnf1000EASX1Port2QinQLocal | read-write | current | Local device Port 2 Q in Q Support : 1:Disable 2:Enable |
| 1.3.6.1.4.1.4756.20.410.40.1.85 | Columnf1000EASX1VID1Local | read-write | current | Local device VID 1: |
| 1.3.6.1.4.1.4756.20.410.40.1.86 | Columnf1000EASX1VID2Local | read-write | current | Local device VID 2: |
| 1.3.6.1.4.1.4756.20.410.40.1.87 | Columnf1000EASX1VID3Local | read-write | current | Local device VID 3: |
| 1.3.6.1.4.1.4756.20.410.40.1.88 | Columnf1000EASX1VID4Local | read-write | current | Local device VID 4: |
| 1.3.6.1.4.1.4756.20.410.40.1.89 | Columnf1000EASX1VID5Local | read-write | current | Local device VID 5: |
| 1.3.6.1.4.1.4756.20.410.40.1.90 | Columnf1000EASX1VID6Local | read-write | current | Local device VID 6: |
| 1.3.6.1.4.1.4756.20.410.40.1.91 | Columnf1000EASX1VID7Local | read-write | current | Local device VID 7: |
| 1.3.6.1.4.1.4756.20.410.40.1.92 | Columnf1000EASX1VID8Local | read-write | current | Local device VID 8: |
| 1.3.6.1.4.1.4756.20.410.40.1.93 | Columnf1000EASX1VID9Local | read-write | current | Local device VID 9: |
| 1.3.6.1.4.1.4756.20.410.40.1.94 | Columnf1000EASX1VID10Local | read-write | current | Local device VID 10: |
| 1.3.6.1.4.1.4756.20.410.40.1.95 | Columnf1000EASX1VID11Local | read-write | current | Local device VID 11: |
| 1.3.6.1.4.1.4756.20.410.40.1.96 | Columnf1000EASX1VID12Local | read-write | current | Local device VID 12: |
| 1.3.6.1.4.1.4756.20.410.40.1.97 | Columnf1000EASX1VID13Local | read-write | current | Local device VID 13: |
| 1.3.6.1.4.1.4756.20.410.40.1.98 | Columnf1000EASX1VID14Local | read-write | current | Local device VID 14: |
| 1.3.6.1.4.1.4756.20.410.40.1.99 | Columnf1000EASX1VID15Local | read-write | current | Local device VID 15: |
| 1.3.6.1.4.1.4756.20.410.40.1.100 | Columnf1000EASX1VID16Local | read-write | current | Local device VID 16: |
| 1.3.6.1.4.1.4756.20.410.40.1.101 | Columnf1000EASX1Port1Member1Local | read-write | current | Local device card port 1 member: 0:Unmodify 1:Untagged 2:Tagged 3:Nonmember |
| 1.3.6.1.4.1.4756.20.410.40.1.102 | Columnf1000EASX1Port1Member2Local | read-write | current | Local device card port 1 member 2: 0:Unmodify 1:Untagged 2:Tagged 3:Nonmember |
| 1.3.6.1.4.1.4756.20.410.40.1.103 | Columnf1000EASX1Port1Member3Local | read-write | current | Local device card port 1 member 3: 0:Unmodify 1:Untagged 2:Tagged 3:Nonmember |
| 1.3.6.1.4.1.4756.20.410.40.1.104 | Columnf1000EASX1Port1Member4Local | read-write | current | Local device card port 1 member 4: 0:Unmodify 1:Untagged 2:Tagged 3:Nonmember |
| 1.3.6.1.4.1.4756.20.410.40.1.105 | Columnf1000EASX1Port1Member5Local | read-write | current | Local device card port 1 member 5: 0:Unmodify 1:Untagged 2:Tagged 3:Nonmember |
| 1.3.6.1.4.1.4756.20.410.40.1.106 | Columnf1000EASX1Port1Member6Local | read-write | current | Local device card port 1 member 6: 0:Unmodify 1:Untagged 2:Tagged 3:Nonmember |
| 1.3.6.1.4.1.4756.20.410.40.1.107 | Columnf1000EASX1Port1Member7Local | read-write | current | Local device card port 1 member 7: 0:Unmodify 1:Untagged 2:Tagged 3:Nonmember |
| 1.3.6.1.4.1.4756.20.410.40.1.108 | Columnf1000EASX1Port1Member8Local | read-write | current | Local device card port 1 member 8: 0:Unmodify 1:Untagged 2:Tagged 3:Nonmember |
| 1.3.6.1.4.1.4756.20.410.40.1.109 | Columnf1000EASX1Port1Member9Local | read-write | current | Local device card port 1 member 9: 0:Unmodify 1:Untagged 2:Tagged 3:Nonmember |
| 1.3.6.1.4.1.4756.20.410.40.1.110 | Columnf1000EASX1Port1Member10Local | read-write | current | Local device card port 1 member 10: 0:Unmodify 1:Untagged 2:Tagged 3:Nonmember |
| 1.3.6.1.4.1.4756.20.410.40.1.111 | Columnf1000EASX1Port1Member11Local | read-write | current | Local device card port 1 member 11: 0:Unmodify 1:Untagged 2:Tagged 3:Nonmember |
| 1.3.6.1.4.1.4756.20.410.40.1.112 | Columnf1000EASX1Port1Member12Local | read-write | current | Local device card port 1 member 12: 0:Unmodify 1:Untagged 2:Tagged 3:Nonmember |
| 1.3.6.1.4.1.4756.20.410.40.1.113 | Columnf1000EASX1Port1Member13Local | read-write | current | Local device card port 1 member 13: 0:Unmodify 1:Untagged 2:Tagged 3:Nonmember |
| 1.3.6.1.4.1.4756.20.410.40.1.114 | Columnf1000EASX1Port1Member14Local | read-write | current | Local device card port 1 member 14: 0:Unmodify 1:Untagged 2:Tagged 3:Nonmember |
| 1.3.6.1.4.1.4756.20.410.40.1.115 | Columnf1000EASX1Port1Member15Local | read-write | current | Local device card port 1 member 15: 0:Unmodify 1:Untagged 2:Tagged 3:Nonmember |
| 1.3.6.1.4.1.4756.20.410.40.1.116 | Columnf1000EASX1Port1Member16Local | read-write | current | Local device card port 1 member 16: 0:Unmodify 1:Untagged 2:Tagged 3:Nonmember |
| 1.3.6.1.4.1.4756.20.410.40.1.117 | Columnf1000EASX1Port2Member1Local | read-write | current | Local device card port 2 member: 0:Unmodify 1:Untagged 2:Tagged 3:Nonmember |
| 1.3.6.1.4.1.4756.20.410.40.1.118 | Columnf1000EASX1Port2Member2Local | read-write | current | Local device card port 2 member 2: 0:Unmodify 1:Untagged 2:Tagged 3:Nonmember |
| 1.3.6.1.4.1.4756.20.410.40.1.119 | Columnf1000EASX1Port2Member3Local | read-write | current | Local device card port 2 member 3: 0:Unmodify 1:Untagged 2:Tagged 3:Nonmember |
| 1.3.6.1.4.1.4756.20.410.40.1.120 | Columnf1000EASX1Port2Member4Local | read-write | current | Local device card port 2 member 4: 0:Unmodify 1:Untagged 2:Tagged 3:Nonmember |
| 1.3.6.1.4.1.4756.20.410.40.1.121 | Columnf1000EASX1Port2Member5Local | read-write | current | Local device card port 2 member 5: 0:Unmodify 1:Untagged 2:Tagged 3:Nonmember |
| 1.3.6.1.4.1.4756.20.410.40.1.122 | Columnf1000EASX1Port2Member6Local | read-write | current | Local device card port 2 member 6: 0:Unmodify 1:Untagged 2:Tagged 3:Nonmember |
| 1.3.6.1.4.1.4756.20.410.40.1.123 | Columnf1000EASX1Port2Member7Local | read-write | current | Local device card port 2 member 7: 0:Unmodify 1:Untagged 2:Tagged 3:Nonmember |
| 1.3.6.1.4.1.4756.20.410.40.1.124 | Columnf1000EASX1Port2Member8Local | read-write | current | Local device card port 2 member 8: 0:Unmodify 1:Untagged 2:Tagged 3:Nonmember |
| 1.3.6.1.4.1.4756.20.410.40.1.125 | Columnf1000EASX1Port2Member9Local | read-write | current | Local device card port 2 member 9: 0:Unmodify 1:Untagged 2:Tagged 3:Nonmember |
| 1.3.6.1.4.1.4756.20.410.40.1.126 | Columnf1000EASX1Port2Member10Local | read-write | current | Local device card port 2 member 10: 0:Unmodify 1:Untagged 2:Tagged 3:Nonmember |
| 1.3.6.1.4.1.4756.20.410.40.1.127 | Columnf1000EASX1Port2Member11Local | read-write | current | Local device card port 2 member 11: 0:Unmodify 1:Untagged 2:Tagged 3:Nonmember |
| 1.3.6.1.4.1.4756.20.410.40.1.128 | Columnf1000EASX1Port2Member12Local | read-write | current | Local device card port 2 member 12: 0:Unmodify 1:Untagged 2:Tagged 3:Nonmember |
| 1.3.6.1.4.1.4756.20.410.40.1.129 | Columnf1000EASX1Port2Member13Local | read-write | current | Local device card port 2 member 13: 0:Unmodify 1:Untagged 2:Tagged 3:Nonmember |
| 1.3.6.1.4.1.4756.20.410.40.1.130 | Columnf1000EASX1Port2Member14Local | read-write | current | Local device card port 2 member 14: 0:Unmodify 1:Untagged 2:Tagged 3:Nonmember |
| 1.3.6.1.4.1.4756.20.410.40.1.131 | Columnf1000EASX1Port2Member15Local | read-write | current | Local device card port 2 member 15: 0:Unmodify 1:Untagged 2:Tagged 3:Nonmember |
| 1.3.6.1.4.1.4756.20.410.40.1.132 | Columnf1000EASX1Port2Member16Local | read-write | current | Local device card port 2 member 16: 0:Unmodify 1:Untagged 2:Tagged 3:Nonmember |
| 1.3.6.1.4.1.4756.20.410.40.1.133 | Columnf1000EASX1IpAddressLocal | read-write | current | Local device IP address |
| 1.3.6.1.4.1.4756.20.410.40.1.134 | Columnf1000EASX1NetMaskLocal | read-write | current | Local device Netmask |
| 1.3.6.1.4.1.4756.20.410.40.1.135 | Columnf1000EASX1GateWayLocal | read-write | current | Local device Gateway |
| 1.3.6.1.4.1.4756.20.410.40.1.136 | Columnf1000EASX1SetDefaultLocal | read-write | current | Local device set to default |
| 1.3.6.1.4.1.4756.20.410.40.1.137 | Columnf1000EASX1ManagementVIDLocal | read-write | current | Local device Management VID : |
| 1.3.6.1.4.1.4756.20.410.40.1.138 | Columnf1000EASX1TagTypeLocal | read-write | current | Local device Tag Type (HEX) : |
| 1.3.6.1.4.1.4756.20.410.40.1.139 | Columnf1000EASX1FxLinkAlarmLocal | read-write | current | Local device fiber link alarm 0:Disable 1:Enable |
| 1.3.6.1.4.1.4756.20.410.40.1.140 | Columnf1000EASX1UtpLinkAlarmLocal | read-write | current | Local device utp link alarm 0:Disable 1:Enable |
| 1.3.6.1.4.1.4756.20.410.40.1.141 | Columnf1000EASX1PingStatusLocal | read-only | current | Local device icmp ping status Show Ping Status 0: Normal 1: Not Ready 2: 5 packets transmitted, 5 received, 0 packet loss. (Ping OK) 3: 5 packets transmitted, … |
| 1.3.6.1.4.1.4756.20.410.40.1.142 | Columnf1000EASX1PingIpAddressLocal | read-write | current | Local device ping IP address |
| 1.3.6.1.4.1.4756.20.410.40.1.143 | Columnf1000EASX1PingStartLocal | read-write | current | Local device ping start 0:Off 1:Action |
| 1.3.6.1.4.1.4756.20.410.40.1.144 | Columnf1000EASX1RemoteTLPTLocal | read-write | current | Local device Remote TLPT mode : 0:Disalbe 1:Remote |
| 1.3.6.1.4.1.4756.20.420 | Nodef1000EASX1RemoteACards | |||
| 1.3.6.1.4.1.4756.20.420.40 | Tablef1000EASX1RemoteATable | not-accessible | current | A list of RemoteA 1000EAS/X-1 card entries. |
| 1.3.6.1.4.1.4756.20.420.40.1 | Rowf1000EASX1RemoteAEntry | not-accessible | current | An entry containing management information applicable to a particular RemoteA f1000EASX-1 card. |
| 1.3.6.1.4.1.4756.20.420.40.1.1 | Columnf1000EASX1ChassisIndexRemoteA | read-only | current | A unique value for each chassis ID. For CH20, it is the chassis ID. For CH08, it is always 0. |
| 1.3.6.1.4.1.4756.20.420.40.1.2 | Columnf1000EASX1SlotIndexRemoteA | read-only | current | A unique value for each RemoteA card. It is the slot location number. |
| 1.3.6.1.4.1.4756.20.420.40.1.3 | Columnf1000EASX1CardHWVerRemoteA | read-only | current | RemoteA device card hardware version x.xxx |
| 1.3.6.1.4.1.4756.20.420.40.1.4 | Columnf1000EASX1CardFWVerRemoteA | read-only | current | RemoteA device card firmware version x.xxx |
| 1.3.6.1.4.1.4756.20.420.40.1.5 | Columnf1000EASX1CardCPLDVerRemoteA | read-only | current | RemoteA device card CPLD version x.xxx |
| 1.3.6.1.4.1.4756.20.420.40.1.6 | Columnf1000EASX1CardFPGAVerRemoteA | read-only | current | RemoteA device card FPGA version x.xxx |
| 1.3.6.1.4.1.4756.20.420.40.1.7 | Columnf1000EASX1ModelRemoteA | read-only | current | RemoteA 1000EAS/X-1 Serial Type |
| 1.3.6.1.4.1.4756.20.420.40.1.8 | Columnf1000EASX1FiberLinkRemoteA | read-only | current | RemoteA device card fiber port link status: 0:Down 1:Up |
| 1.3.6.1.4.1.4756.20.420.40.1.9 | Columnf1000EASX1FiberOAMLoopedRemoteA | read-only | current | RemoteA device card fiber port OAM looped: 0:Off 1:on |
| 1.3.6.1.4.1.4756.20.420.40.1.10 | Columnf1000EASX1FiberLBTestRemoteA | read-write | current | Force remote device card to do fiber port LoopBack testing: 0:Off 1:Action |
| 1.3.6.1.4.1.4756.20.420.40.1.11 | Columnf1000EASX1FiberOAMRLBStatusRemoteA | read-only | current | RemoteA device card fiber port LoopBack testing status: 0:Off 1:Ok 2:Fail |
| 1.3.6.1.4.1.4756.20.420.40.1.12 | Columnf1000EASX1FiberRemoPwrAbRemoteA | read-only | current | RemoteA device card fiber port RemoteA Power status: 0:Abnormal 1:OK 2:None |
| 1.3.6.1.4.1.4756.20.420.40.1.13 | Columnf1000EASX1FiberFEFRemoteA | read-only | current | RemoteA device card fiber port FEF status: 0:Abnormal 1:OFF 2:Detected |
| 1.3.6.1.4.1.4756.20.420.40.1.14 | Columnf1000EASX1FiberIngressRateRemoteA | read-write | current | RemoteA device card fiber Ingress Rate Limit: 0 = Unlimit input format: 64k(K),100m(M),100 If doesn't input the unit, the default was Mega. Limite Rate : 64K ~… |
| 1.3.6.1.4.1.4756.20.420.40.1.15 | Columnf1000EASX1FiberEgressRateRemoteA | read-write | current | RemoteA device card fiber Egress Rate Limit: 0 = Unlimit input format: 64k(K),100m(M),100 If doesn't input the unit, the default was Mega. Limite Rate : 64K ~ … |
| 1.3.6.1.4.1.4756.20.420.40.1.16 | Columnf1000EASX1UtpLinkRemoteA | read-only | current | RemoteA device card UTP port link status: 0:Down 1:Up |
| 1.3.6.1.4.1.4756.20.420.40.1.17 | Columnf1000EASX1UtpNegoRemoteA | read-write | current | RemoteA device card UTP port negotiation status: 0:Manual 1:Auto |
| 1.3.6.1.4.1.4756.20.420.40.1.18 | Columnf1000EASX1UtpSpeedRemoteA | read-write | current | RemoteA device card UTP port speed setting: 0:10 Base-T 1:100 Base-TX 2:1000 Base-TX |
| 1.3.6.1.4.1.4756.20.420.40.1.19 | Columnf1000EASX1UtpDuplexRemoteA | read-write | current | RemoteA device card UTP port duplex setting: 0:Half duplex mode 1:Full duplex mode |
| 1.3.6.1.4.1.4756.20.420.40.1.20 | Columnf1000EASX1UtpSpeedStatusRemoteA | read-only | current | RemoteA device card UTP port speed status: 0:10 Base-T 1:100 Base-TX 2:1000 Base-TX |
| 1.3.6.1.4.1.4756.20.420.40.1.21 | Columnf1000EASX1UtpDuplexStatusRemoteA | read-only | current | RemoteA device card UTP port duplex status: 0:Half duplex mode 1:Full duplex mode |
| 1.3.6.1.4.1.4756.20.420.40.1.22 | Columnf1000EASX1UtpIngressRateRemoteA | read-write | current | RemoteA device card utp Ingress Rate Limit: 0 = Unlimit input format: 64k(K),100m(M),100 If doesn't input the unit, the default was Mega. Limite Rate : 64K ~ 9… |
| 1.3.6.1.4.1.4756.20.420.40.1.23 | Columnf1000EASX1UtpEgressRateRemoteA | read-write | current | RemoteA device card utp Egress Rate Limit: 0 = Unlimit input format: 64k(K),100m(M),100 If doesn't input the unit, the default was Mega. Limite Rate : 64K ~ 99… |
| 1.3.6.1.4.1.4756.20.420.40.1.24 | Columnf1000EASX1DeviceResetRemoteA | read-write | current | Force RemoteA device card to reset mode: 0:Off 1:Action |
| 1.3.6.1.4.1.4756.20.420.40.1.25 | Columnf1000EASX1UtpActiveRemoteA | read-write | current | RemoteA device UTP port active mode: 0:Disable 1:Enable |
| 1.3.6.1.4.1.4756.20.420.40.1.26 | Columnf1000EASX1OamChModeRemoteA | read-write | current | RemoteA device OAM Channel mode: 0:Disable 1:passive 2:Active |
| 1.3.6.1.4.1.4756.20.420.40.1.27 | Columnf1000EASX1OamMaxPDUsRemoteA | read-write | current | RemoteA device OAM max OAMPDU size: 60-1518 Octets |
| 1.3.6.1.4.1.4756.20.420.40.1.28 | Columnf1000EASX1FiberAlsRemoteA | read-write | current | RemoteA device card port Auto Laser Shutdown mode: 0:Disable 1:Enable |
| 1.3.6.1.4.1.4756.20.420.40.1.29 | Columnf1000EASX1PauseFrameRemoteA | read-write | current | RemoteA device card pause frame mode: 0:Disable 1:Enable |
| 1.3.6.1.4.1.4756.20.420.40.1.30 | Columnf1000EASX1FHRModeRemoteA | read-write | current | RemoteA device card FHR Mode: 0:Disable 1:Enable |
| 1.3.6.1.4.1.4756.20.420.40.1.31 | Columnf1000EASX1FiberLLFDepPortRemoteA | read-write | current | RemoteA device card port Link Loss Forwarding depends on port Ethernet Rx link: 0:don't care 1:selected |
| 1.3.6.1.4.1.4756.20.420.40.1.32 | Columnf1000EASX1UtpLLFDepPortRemoteA | read-write | current | RemoteA device card port Link Loss Forwarding depends on port Fiber Rx link: 0:don't care 1:selected |
| 1.3.6.1.4.1.4756.20.420.40.1.33 | Columnf1000EASX1AdvanceFunsRemoteA | read-write | current | RemoteA device card Switch functions mode: 0:Normal 5:Static 802.1Q VLAN 6:Spanning Tree Protocol 7:802.1Q VLAN Trunk 9:Q in Q VLAN 11:Spanning Tree Protocol &… |
| 1.3.6.1.4.1.4756.20.420.40.1.34 | Columnf1000EASX1FiberInfoROM1RemoteA | read-only | current | RemoteA device card port INFORemoteAOM information 1 valid: 0:Invalid 1:Valid |
| 1.3.6.1.4.1.4756.20.420.40.1.35 | Columnf1000EASX1FiberInfoROM2RemoteA | read-only | current | RemoteA device card port INFORemoteAOM information 2 valid: 0:Invalid 1:Valid(replacing D/D function |
| 1.3.6.1.4.1.4756.20.420.40.1.36 | Columnf1000EASX1FiberInfoSN1RemoteA | read-only | current | RemoteA device card port INFORemoteAOM S/N 1 |
| 1.3.6.1.4.1.4756.20.420.40.1.37 | Columnf1000EASX1FiberInfoSN2RemoteA | read-only | current | RemoteA device card port INFORemoteAOM S/N 2 |
| 1.3.6.1.4.1.4756.20.420.40.1.38 | Columnf1000EASX1FiberDDRemoteA | read-only | current | RemoteA device card fiber port Digital Diagnostic function: 0:No 1:Yes |
| 1.3.6.1.4.1.4756.20.420.40.1.39 | Columnf1000EASX1FiberDDVendorRemoteA | read-only | current | RemoteA device card fiber port D/D information: Vendor name |
| 1.3.6.1.4.1.4756.20.420.40.1.40 | Columnf1000EASX1FiberDDPartNoRemoteA | read-only | current | RemoteA device card fiber port D/D information: Vendor part number |
| 1.3.6.1.4.1.4756.20.420.40.1.41 | Columnf1000EASX1FiberDDVendorSNRemoteA | read-only | current | RemoteA device card fiber port D/D information: Vendor Serial Number |
| 1.3.6.1.4.1.4756.20.420.40.1.42 | Columnf1000EASX1FiberDDFiberTypeRemoteA | read-only | current | RemoteA device card fiber port D/D information: Fiber Type |
| 1.3.6.1.4.1.4756.20.420.40.1.43 | Columnf1000EASX1FiberDDWaveLenRemoteA | read-only | current | RemoteA device card fiber port D/D information: Wave length |
| 1.3.6.1.4.1.4756.20.420.40.1.44 | Columnf1000EASX1FiberDDWaveLen2RemoteA | read-only | current | RemoteA device card fiber port D/D information: Wave length 2 |
| 1.3.6.1.4.1.4756.20.420.40.1.45 | Columnf1000EASX1FiberDDLinkLenRemoteA | read-only | current | RemoteA device card fiber port D/D information: Link length |
| 1.3.6.1.4.1.4756.20.420.40.1.46 | Columnf1000EASX1FiberDDLenUnitRemoteA | read-only | current | RemoteA device card fiber port D/D information: Length Unit |
| 1.3.6.1.4.1.4756.20.420.40.1.47 | Columnf1000EASX1FiberDDStatusRemoteA | read-only | current | RemoteA device card fiber port D/D information: Status Support |
| 1.3.6.1.4.1.4756.20.420.40.1.48 | Columnf1000EASX1FiberDDRxSensRemoteA | read-only | current | RemoteA device card fiber port D/D information: Rx Sensitivity |
| 1.3.6.1.4.1.4756.20.420.40.1.49 | Columnf1000EASX1FiberDDTxPWRRemoteA | read-only | current | RemoteA device card fiber port D/D information: Tx power |
| 1.3.6.1.4.1.4756.20.420.40.1.50 | Columnf1000EASX1FiberDDRxPWRRemoteA | read-only | current | RemoteA device card fiber port D/D information: Rx power |
| 1.3.6.1.4.1.4756.20.420.40.1.51 | Columnf1000EASX1FiberDDTempRemoteA | read-only | current | RemoteA device card fiber port D/D information: Temperature in degree C |
| 1.3.6.1.4.1.4756.20.420.40.1.52 | Columnf1000EASX1FiberDDPWRMarginRemoteA | read-only | current | RemoteA device card fiber port D/D information: Power margin |
| 1.3.6.1.4.1.4756.20.420.40.1.53 | Columnf1000EASX1FiberDDPWRLossRemoteA | read-only | current | RemoteA device card fiber port D/D information: Power loss |
| 1.3.6.1.4.1.4756.20.420.40.1.54 | Columnf1000EASX1ClrRMONCntsRemoteA | read-write | current | Clear RemoteA device card RMON IN/OUT counters: 0:No action 1:Action |
| 1.3.6.1.4.1.4756.20.420.40.1.55 | Columnf1000EASX1FiberRMONInRemoteA | read-only | current | RemoteA device card port RMON IN counter. |
| 1.3.6.1.4.1.4756.20.420.40.1.56 | Columnf1000EASX1FiberRMONOutRemoteA | read-only | current | RemoteA device card port RMON OUT counter. |
| 1.3.6.1.4.1.4756.20.420.40.1.57 | Columnf1000EASX1UtpRMONInRemoteA | read-only | current | RemoteA device card port RMON IN counter. |
| 1.3.6.1.4.1.4756.20.420.40.1.58 | Columnf1000EASX1UtpRMONOutRemoteA | read-only | current | RemoteA device card port RMON OUT counter. |
| 1.3.6.1.4.1.4756.20.420.40.1.59 | Columnf1000EASX1ClrOAMCntsRemoteA | read-write | current | Clear RemoteA device card OAM counters: 0:No action 1:Action |
| 1.3.6.1.4.1.4756.20.420.40.1.60 | Columnf1000EASX1IpModeRemoteA | read-write | current | On Rack Ip Mode: 0:Enable 1:Disable |
| 1.3.6.1.4.1.4756.20.420.40.1.61 | Columnf1000EASX1OamChTxRemoteA | read-only | current | RemoteA device OAM Channel TX OAMPDU frame count |
| 1.3.6.1.4.1.4756.20.420.40.1.62 | Columnf1000EASX1OamChRxRemoteA | read-only | current | RemoteA device OAM Channel RX OAMPDU frame count |
| 1.3.6.1.4.1.4756.20.420.40.1.63 | Columnf1000EASX1OamInfoChTxRemoteA | read-only | current | RemoteA device OAM Channel TX Information OAMPDU frame count |
| 1.3.6.1.4.1.4756.20.420.40.1.64 | Columnf1000EASX1OamInfoChRxRemoteA | read-only | current | RemoteA device OAM Channel RX Information OAMPDU frame count |
| 1.3.6.1.4.1.4756.20.420.40.1.65 | Columnf1000EASX1OamEventChTxRemoteA | read-only | current | RemoteA device OAM Channel TX Event OAMPDU frame count |
| 1.3.6.1.4.1.4756.20.420.40.1.66 | Columnf1000EASX1OamUniEvtChRxRemoteA | read-only | current | RemoteA device OAM Channel RX Unique Event OAMPDU frame count |
| 1.3.6.1.4.1.4756.20.420.40.1.67 | Columnf1000EASX1OamDupEvtChRxRemoteA | read-only | current | RemoteA device OAM Channel RX Duplicate Event OAMPDU frame count |
| 1.3.6.1.4.1.4756.20.420.40.1.68 | Columnf1000EASX1OamLbChTxRemoteA | read-only | current | RemoteA device OAM Channel TX Loopback Control OAMPDU frame count |
| 1.3.6.1.4.1.4756.20.420.40.1.69 | Columnf1000EASX1OamLbChRxRemoteA | read-only | current | RemoteA device OAM Channel RX Loopback Control OAMPDU frame count |
| 1.3.6.1.4.1.4756.20.420.40.1.70 | Columnf1000EASX1OamVarReqChTxRemoteA | read-only | current | RemoteA device OAM Channel TX Variable Request OAMPDU frame count |
| 1.3.6.1.4.1.4756.20.420.40.1.71 | Columnf1000EASX1OamVarReqChRxRemoteA | read-only | current | RemoteA device OAM Channel RX Variable Request OAMPDU frame count |
| 1.3.6.1.4.1.4756.20.420.40.1.72 | Columnf1000EASX1OamVarRspChTxRemoteA | read-only | current | RemoteA device OAM Channel TX Variable Response OAMPDU frame count |
| 1.3.6.1.4.1.4756.20.420.40.1.73 | Columnf1000EASX1OamVarRspChRxRemoteA | read-only | current | RemoteA device OAM Channel RX Variable Response OAMPDU frame count |
| 1.3.6.1.4.1.4756.20.420.40.1.74 | Columnf1000EASX1OamOuiChTxRemoteA | read-only | current | RemoteA device OAM Channel TX OUI OAMPDU frame count |
| 1.3.6.1.4.1.4756.20.420.40.1.75 | Columnf1000EASX1OamOuiChRxRemoteA | read-only | current | RemoteA device OAM Channel RX OUI OAMPDU frame count |
| 1.3.6.1.4.1.4756.20.420.40.1.76 | Columnf1000EASX1OamUnknowChRxRemoteA | read-only | current | RemoteA device OAM Channel RX Unsupported OAMPDU frame count |
| 1.3.6.1.4.1.4756.20.420.40.1.77 | Columnf1000EASX1FiberSpeedRemoteA | read-only | current | RemoteA device Fiber speed : 0:1000 1:100 |
| 1.3.6.1.4.1.4756.20.420.40.1.78 | Columnf1000EASX1MacLearningRemoteA | read-write | current | RemoteA device Mac learning : 0:Disable 1:Enable |
| 1.3.6.1.4.1.4756.20.420.40.1.79 | Columnf1000EASX1Port1VIDRemoteA | read-write | current | RemoteA device Port 1 VID : |
| 1.3.6.1.4.1.4756.20.420.40.1.80 | Columnf1000EASX1Port2VIDRemoteA | read-write | current | RemoteA device Port 2 VID : |
| 1.3.6.1.4.1.4756.20.420.40.1.81 | Columnf1000EASX1Port1QinQRemoteA | read-write | current | RemoteA device Port 1 Q in Q Support : 1:Disable 2:Enable |
| 1.3.6.1.4.1.4756.20.420.40.1.82 | Columnf1000EASX1Port2QinQRemoteA | read-write | current | RemoteA device Port 2 Q in Q Support : 1:Disable 2:Enable |
| 1.3.6.1.4.1.4756.20.420.40.1.83 | Columnf1000EASX1VID1RemoteA | read-write | current | RemoteA device VID 1: |
| 1.3.6.1.4.1.4756.20.420.40.1.84 | Columnf1000EASX1VID2RemoteA | read-write | current | RemoteA device VID 2: |
| 1.3.6.1.4.1.4756.20.420.40.1.85 | Columnf1000EASX1VID3RemoteA | read-write | current | RemoteA device VID 3: |
| 1.3.6.1.4.1.4756.20.420.40.1.86 | Columnf1000EASX1VID4RemoteA | read-write | current | RemoteA device VID 4: |
| 1.3.6.1.4.1.4756.20.420.40.1.87 | Columnf1000EASX1VID5RemoteA | read-write | current | RemoteA device VID 5: |
| 1.3.6.1.4.1.4756.20.420.40.1.88 | Columnf1000EASX1VID6RemoteA | read-write | current | RemoteA device VID 6: |
| 1.3.6.1.4.1.4756.20.420.40.1.89 | Columnf1000EASX1VID7RemoteA | read-write | current | RemoteA device VID 7: |
| 1.3.6.1.4.1.4756.20.420.40.1.90 | Columnf1000EASX1VID8RemoteA | read-write | current | RemoteA device VID 8: |
| 1.3.6.1.4.1.4756.20.420.40.1.91 | Columnf1000EASX1VID9RemoteA | read-write | current | RemoteA device VID 9: |
| 1.3.6.1.4.1.4756.20.420.40.1.92 | Columnf1000EASX1VID10RemoteA | read-write | current | RemoteA device VID 10: |
| 1.3.6.1.4.1.4756.20.420.40.1.93 | Columnf1000EASX1VID11RemoteA | read-write | current | RemoteA device VID 11: |
| 1.3.6.1.4.1.4756.20.420.40.1.94 | Columnf1000EASX1VID12RemoteA | read-write | current | RemoteA device VID 12: |
| 1.3.6.1.4.1.4756.20.420.40.1.95 | Columnf1000EASX1VID13RemoteA | read-write | current | RemoteA device VID 13: |
| 1.3.6.1.4.1.4756.20.420.40.1.96 | Columnf1000EASX1VID14RemoteA | read-write | current | RemoteA device VID 14: |
| 1.3.6.1.4.1.4756.20.420.40.1.97 | Columnf1000EASX1VID15RemoteA | read-write | current | RemoteA device VID 15: |
| 1.3.6.1.4.1.4756.20.420.40.1.98 | Columnf1000EASX1VID16RemoteA | read-write | current | RemoteA device VID 16: |
| 1.3.6.1.4.1.4756.20.420.40.1.99 | Columnf1000EASX1Port1Member1RemoteA | read-write | current | RemoteA device card port 1 member: 0:Unmodify 1:Untagged 2:Tagged 3:Nonmember |
| 1.3.6.1.4.1.4756.20.420.40.1.100 | Columnf1000EASX1Port1Member2RemoteA | read-write | current | RemoteA device card port 1 member 2: 0:Unmodify 1:Untagged 2:Tagged 3:Nonmember |
| 1.3.6.1.4.1.4756.20.420.40.1.101 | Columnf1000EASX1Port1Member3RemoteA | read-write | current | RemoteA device card port 1 member 3: 0:Unmodify 1:Untagged 2:Tagged 3:Nonmember |
| 1.3.6.1.4.1.4756.20.420.40.1.102 | Columnf1000EASX1Port1Member4RemoteA | read-write | current | RemoteA device card port 1 member 4: 0:Unmodify 1:Untagged 2:Tagged 3:Nonmember |
| 1.3.6.1.4.1.4756.20.420.40.1.103 | Columnf1000EASX1Port1Member5RemoteA | read-write | current | RemoteA device card port 1 member 5: 0:Unmodify 1:Untagged 2:Tagged 3:Nonmember |
| 1.3.6.1.4.1.4756.20.420.40.1.104 | Columnf1000EASX1Port1Member6RemoteA | read-write | current | RemoteA device card port 1 member 6: 0:Unmodify 1:Untagged 2:Tagged 3:Nonmember |
| 1.3.6.1.4.1.4756.20.420.40.1.105 | Columnf1000EASX1Port1Member7RemoteA | read-write | current | RemoteA device card port 1 member 7: 0:Unmodify 1:Untagged 2:Tagged 3:Nonmember |
| 1.3.6.1.4.1.4756.20.420.40.1.106 | Columnf1000EASX1Port1Member8RemoteA | read-write | current | RemoteA device card port 1 member 8: 0:Unmodify 1:Untagged 2:Tagged 3:Nonmember |
| 1.3.6.1.4.1.4756.20.420.40.1.107 | Columnf1000EASX1Port1Member9RemoteA | read-write | current | RemoteA device card port 1 member 9: 0:Unmodify 1:Untagged 2:Tagged 3:Nonmember |
| 1.3.6.1.4.1.4756.20.420.40.1.108 | Columnf1000EASX1Port1Member10RemoteA | read-write | current | RemoteA device card port 1 member 10: 0:Unmodify 1:Untagged 2:Tagged 3:Nonmember |
| 1.3.6.1.4.1.4756.20.420.40.1.109 | Columnf1000EASX1Port1Member11RemoteA | read-write | current | RemoteA device card port 1 member 11: 0:Unmodify 1:Untagged 2:Tagged 3:Nonmember |
| 1.3.6.1.4.1.4756.20.420.40.1.110 | Columnf1000EASX1Port1Member12RemoteA | read-write | current | RemoteA device card port 1 member 12: 0:Unmodify 1:Untagged 2:Tagged 3:Nonmember |
| 1.3.6.1.4.1.4756.20.420.40.1.111 | Columnf1000EASX1Port1Member13RemoteA | read-write | current | RemoteA device card port 1 member 13: 0:Unmodify 1:Untagged 2:Tagged 3:Nonmember |
| 1.3.6.1.4.1.4756.20.420.40.1.112 | Columnf1000EASX1Port1Member14RemoteA | read-write | current | RemoteA device card port 1 member 14: 0:Unmodify 1:Untagged 2:Tagged 3:Nonmember |
| 1.3.6.1.4.1.4756.20.420.40.1.113 | Columnf1000EASX1Port1Member15RemoteA | read-write | current | RemoteA device card port 1 member 15: 0:Unmodify 1:Untagged 2:Tagged 3:Nonmember |
| 1.3.6.1.4.1.4756.20.420.40.1.114 | Columnf1000EASX1Port1Member16RemoteA | read-write | current | RemoteA device card port 1 member 16: 0:Unmodify 1:Untagged 2:Tagged 3:Nonmember |
| 1.3.6.1.4.1.4756.20.420.40.1.115 | Columnf1000EASX1Port2Member1RemoteA | read-write | current | RemoteA device card port 2 member: 0:Unmodify 1:Untagged 2:Tagged 3:Nonmember |
| 1.3.6.1.4.1.4756.20.420.40.1.116 | Columnf1000EASX1Port2Member2RemoteA | read-write | current | RemoteA device card port 2 member 2: 0:Unmodify 1:Untagged 2:Tagged 3:Nonmember |
| 1.3.6.1.4.1.4756.20.420.40.1.117 | Columnf1000EASX1Port2Member3RemoteA | read-write | current | RemoteA device card port 2 member 3: 0:Unmodify 1:Untagged 2:Tagged 3:Nonmember |
| 1.3.6.1.4.1.4756.20.420.40.1.118 | Columnf1000EASX1Port2Member4RemoteA | read-write | current | RemoteA device card port 2 member 4: 0:Unmodify 1:Untagged 2:Tagged 3:Nonmember |
| 1.3.6.1.4.1.4756.20.420.40.1.119 | Columnf1000EASX1Port2Member5RemoteA | read-write | current | RemoteA device card port 2 member 5: 0:Unmodify 1:Untagged 2:Tagged 3:Nonmember |
| 1.3.6.1.4.1.4756.20.420.40.1.120 | Columnf1000EASX1Port2Member6RemoteA | read-write | current | RemoteA device card port 2 member 6: 0:Unmodify 1:Untagged 2:Tagged 3:Nonmember |
| 1.3.6.1.4.1.4756.20.420.40.1.121 | Columnf1000EASX1Port2Member7RemoteA | read-write | current | RemoteA device card port 2 member 7: 0:Unmodify 1:Untagged 2:Tagged 3:Nonmember |
| 1.3.6.1.4.1.4756.20.420.40.1.122 | Columnf1000EASX1Port2Member8RemoteA | read-write | current | RemoteA device card port 2 member 8: 0:Unmodify 1:Untagged 2:Tagged 3:Nonmember |
| 1.3.6.1.4.1.4756.20.420.40.1.123 | Columnf1000EASX1Port2Member9RemoteA | read-write | current | RemoteA device card port 2 member 9: 0:Unmodify 1:Untagged 2:Tagged 3:Nonmember |
| 1.3.6.1.4.1.4756.20.420.40.1.124 | Columnf1000EASX1Port2Member10RemoteA | read-write | current | RemoteA device card port 2 member 10: 0:Unmodify 1:Untagged 2:Tagged 3:Nonmember |
| 1.3.6.1.4.1.4756.20.420.40.1.125 | Columnf1000EASX1Port2Member11RemoteA | read-write | current | RemoteA device card port 2 member 11: 0:Unmodify 1:Untagged 2:Tagged 3:Nonmember |
| 1.3.6.1.4.1.4756.20.420.40.1.126 | Columnf1000EASX1Port2Member12RemoteA | read-write | current | RemoteA device card port 2 member 12: 0:Unmodify 1:Untagged 2:Tagged 3:Nonmember |
| 1.3.6.1.4.1.4756.20.420.40.1.127 | Columnf1000EASX1Port2Member13RemoteA | read-write | current | RemoteA device card port 2 member 13: 0:Unmodify 1:Untagged 2:Tagged 3:Nonmember |
| 1.3.6.1.4.1.4756.20.420.40.1.128 | Columnf1000EASX1Port2Member14RemoteA | read-write | current | RemoteA device card port 2 member 14: 0:Unmodify 1:Untagged 2:Tagged 3:Nonmember |
| 1.3.6.1.4.1.4756.20.420.40.1.129 | Columnf1000EASX1Port2Member15RemoteA | read-write | current | RemoteA device card port 2 member 15: 0:Unmodify 1:Untagged 2:Tagged 3:Nonmember |
| 1.3.6.1.4.1.4756.20.420.40.1.130 | Columnf1000EASX1Port2Member16RemoteA | read-write | current | RemoteA device card port 2 member 16: 0:Unmodify 1:Untagged 2:Tagged 3:Nonmember |
| 1.3.6.1.4.1.4756.20.420.40.1.131 | Columnf1000EASX1IpAddressRemoteA | read-write | current | RemoteA device IP address |
| 1.3.6.1.4.1.4756.20.420.40.1.132 | Columnf1000EASX1NetMaskRemoteA | read-write | current | RemoteA device Netmask |
| 1.3.6.1.4.1.4756.20.420.40.1.133 | Columnf1000EASX1GateWayRemoteA | read-write | current | RemoteA device Gateway |
| 1.3.6.1.4.1.4756.20.420.40.1.134 | Columnf1000EASX1SetDefaultRemoteA | read-write | current | RemoteA device set to default |
| 1.3.6.1.4.1.4756.20.420.40.1.135 | Columnf1000EASX1ManagementVIDRemoteA | read-write | current | RemoteA device Management VID : |
| 1.3.6.1.4.1.4756.20.420.40.1.136 | Columnf1000EASX1TagTypeRemoteA | read-write | current | RemoteA device Tag Type (HEX) : |
| 1.3.6.1.4.1.4756.20.420.40.1.137 | Columnf1000EASX1FxLinkAlarmRemoteA | read-write | current | RemoteA device fiber link alarm 0:Disable 1:Enable |
| 1.3.6.1.4.1.4756.20.420.40.1.138 | Columnf1000EASX1UtpLinkAlarmRemoteA | read-write | current | RemoteA device utp link alarm 0:Disable 1:Enable |
| 1.3.6.1.4.1.4756.20.420.40.1.139 | Columnf1000EASX1RemoteTLPTRemoteA | read-write | current | RemoteA device Remote TLPT mode : 0:Disalbe 1:Remote |
| 1.3.6.1.4.1.4756.20.421 | Nodef1000EASX1RemoteBCards | |||
| 1.3.6.1.4.1.4756.20.421.40 | Tablef1000EASX1RemoteBTable | not-accessible | current | A list of RemoteB 1000EAS/X-1 card entries. |
| 1.3.6.1.4.1.4756.20.421.40.1 | Rowf1000EASX1RemoteBEntry | not-accessible | current | An entry containing management information applicable to a particular RemoteB f1000EASX-1 card. |
| 1.3.6.1.4.1.4756.20.421.40.1.1 | Columnf1000EASX1ChassisIndexRemoteB | read-only | current | A unique value for each chassis ID. For CH20, it is the chassis ID. For CH08, it is always 0. |
| 1.3.6.1.4.1.4756.20.421.40.1.2 | Columnf1000EASX1SlotIndexRemoteB | read-only | current | A unique value for each RemoteB card. It is the slot location number. |
| 1.3.6.1.4.1.4756.20.421.40.1.3 | Columnf1000EASX1CardHWVerRemoteB | read-only | current | RemoteB device card hardware version x.xxx |
| 1.3.6.1.4.1.4756.20.421.40.1.4 | Columnf1000EASX1CardFWVerRemoteB | read-only | current | RemoteB device card firmware version x.xxx |
| 1.3.6.1.4.1.4756.20.421.40.1.5 | Columnf1000EASX1CardCPLDVerRemoteB | read-only | current | RemoteB device card CPLD version x.xxx |
| 1.3.6.1.4.1.4756.20.421.40.1.6 | Columnf1000EASX1CardFPGAVerRemoteB | read-only | current | RemoteB device card FPGA version x.xxx |
| 1.3.6.1.4.1.4756.20.421.40.1.7 | Columnf1000EASX1ModelRemoteB | read-only | current | RemoteB 1000EAS/X-1 Serial Type |
| 1.3.6.1.4.1.4756.20.421.40.1.8 | Columnf1000EASX1FiberLinkRemoteB | read-only | current | RemoteB device card fiber port link status: 0:Down 1:Up |
| 1.3.6.1.4.1.4756.20.421.40.1.9 | Columnf1000EASX1FiberOAMLoopedRemoteB | read-only | current | RemoteB device card fiber port OAM looped: 0:Off 1:on |
| 1.3.6.1.4.1.4756.20.421.40.1.10 | Columnf1000EASX1FiberLBTestRemoteB | read-write | current | Force remote device card to do fiber port LoopBack testing: 0:Off 1:Action |
| 1.3.6.1.4.1.4756.20.421.40.1.11 | Columnf1000EASX1FiberOAMRLBStatusRemoteB | read-only | current | RemoteB device card fiber port LoopBack testing status: 0:Off 1:Ok 2:Fail |
| 1.3.6.1.4.1.4756.20.421.40.1.12 | Columnf1000EASX1FiberRemoPwrAbRemoteB | read-only | current | RemoteB device card fiber port RemoteB Power status: 0:Abnormal 1:OK 2:None |
| 1.3.6.1.4.1.4756.20.421.40.1.13 | Columnf1000EASX1FiberFEFRemoteB | read-only | current | RemoteB device card fiber port FEF status: 0:Abnormal 1:OFF 2:Detected |
| 1.3.6.1.4.1.4756.20.421.40.1.14 | Columnf1000EASX1FiberIngressRateRemoteB | read-write | current | RemoteB device card fiber Ingress Rate Limit: 0 = Unlimit input format: 64k(K),100m(M),100 If doesn't input the unit, the default was Mega. Limite Rate : 64K ~… |
| 1.3.6.1.4.1.4756.20.421.40.1.15 | Columnf1000EASX1FiberEgressRateRemoteB | read-write | current | RemoteB device card fiber Egress Rate Limit: 0 = Unlimit input format: 64k(K),100m(M),100 If doesn't input the unit, the default was Mega. Limite Rate : 64K ~ … |
| 1.3.6.1.4.1.4756.20.421.40.1.16 | Columnf1000EASX1UtpLinkRemoteB | read-only | current | RemoteB device card UTP port link status: 0:Down 1:Up |
| 1.3.6.1.4.1.4756.20.421.40.1.17 | Columnf1000EASX1UtpNegoRemoteB | read-write | current | RemoteB device card UTP port negotiation status: 0:Manual 1:Auto |
| 1.3.6.1.4.1.4756.20.421.40.1.18 | Columnf1000EASX1UtpSpeedRemoteB | read-write | current | RemoteB device card UTP port speed setting: 0:10 Base-T 1:100 Base-TX 2:1000 Base-TX |
| 1.3.6.1.4.1.4756.20.421.40.1.19 | Columnf1000EASX1UtpDuplexRemoteB | read-write | current | RemoteB device card UTP port duplex setting: 0:Half duplex mode 1:Full duplex mode |
| 1.3.6.1.4.1.4756.20.421.40.1.20 | Columnf1000EASX1UtpSpeedStatusRemoteB | read-only | current | RemoteB device card UTP port speed status: 0:10 Base-T 1:100 Base-TX 2:1000 Base-TX |
| 1.3.6.1.4.1.4756.20.421.40.1.21 | Columnf1000EASX1UtpDuplexStatusRemoteB | read-only | current | RemoteB device card UTP port duplex status: 0:Half duplex mode 1:Full duplex mode |
| 1.3.6.1.4.1.4756.20.421.40.1.22 | Columnf1000EASX1UtpIngressRateRemoteB | read-write | current | RemoteB device card utp Ingress Rate Limit: 0 = Unlimit input format: 64k(K),100m(M),100 If doesn't input the unit, the default was Mega. Limite Rate : 64K ~ 9… |
| 1.3.6.1.4.1.4756.20.421.40.1.23 | Columnf1000EASX1UtpEgressRateRemoteB | read-write | current | RemoteB device card utp Egress Rate Limit: 0 = Unlimit input format: 64k(K),100m(M),100 If doesn't input the unit, the default was Mega. Limite Rate : 64K ~ 99… |
| 1.3.6.1.4.1.4756.20.421.40.1.24 | Columnf1000EASX1DeviceResetRemoteB | read-write | current | Force RemoteB device card to reset mode: 0:Off 1:Action |
| 1.3.6.1.4.1.4756.20.421.40.1.25 | Columnf1000EASX1UtpActiveRemoteB | read-write | current | RemoteB device UTP port active mode: 0:Disable 1:Enable |
| 1.3.6.1.4.1.4756.20.421.40.1.26 | Columnf1000EASX1OamChModeRemoteB | read-write | current | RemoteB device OAM Channel mode: 0:Disable 1:passive 2:Active |
| 1.3.6.1.4.1.4756.20.421.40.1.27 | Columnf1000EASX1OamMaxPDUsRemoteB | read-write | current | RemoteB device OAM max OAMPDU size: 60-1518 Octets |
| 1.3.6.1.4.1.4756.20.421.40.1.28 | Columnf1000EASX1FiberAlsRemoteB | read-write | current | RemoteB device card port Auto Laser Shutdown mode: 0:Disable 1:Enable |
| 1.3.6.1.4.1.4756.20.421.40.1.29 | Columnf1000EASX1PauseFrameRemoteB | read-write | current | RemoteB device card pause frame mode: 0:Disable 1:Enable |
| 1.3.6.1.4.1.4756.20.421.40.1.30 | Columnf1000EASX1FHRModeRemoteB | read-write | current | RemoteB device card FHR Mode: 0:Disable 1:Enable |
| 1.3.6.1.4.1.4756.20.421.40.1.31 | Columnf1000EASX1FiberLLFDepPortRemoteB | read-write | current | RemoteB device card port Link Loss Forwarding depends on port Ethernet Rx link: 0:don't care 1:selected |
| 1.3.6.1.4.1.4756.20.421.40.1.32 | Columnf1000EASX1UtpLLFDepPortRemoteB | read-write | current | RemoteB device card port Link Loss Forwarding depends on port Fiber Rx link: 0:don't care 1:selected |
| 1.3.6.1.4.1.4756.20.421.40.1.33 | Columnf1000EASX1AdvanceFunsRemoteB | read-write | current | RemoteB device card Switch functions mode: 0:Normal 5:Static 802.1Q VLAN 6:Spanning Tree Protocol 7:802.1Q VLAN Trunk 9:Q in Q VLAN 11:Spanning Tree Protocol &… |
| 1.3.6.1.4.1.4756.20.421.40.1.34 | Columnf1000EASX1FiberInfoROM1RemoteB | read-only | current | RemoteB device card port INFORemoteBOM information 1 valid: 0:Invalid 1:Valid |
| 1.3.6.1.4.1.4756.20.421.40.1.35 | Columnf1000EASX1FiberInfoROM2RemoteB | read-only | current | RemoteB device card port INFORemoteBOM information 2 valid: 0:Invalid 1:Valid(replacing D/D function |
| 1.3.6.1.4.1.4756.20.421.40.1.36 | Columnf1000EASX1FiberInfoSN1RemoteB | read-only | current | RemoteB device card port INFORemoteBOM S/N 1 |
| 1.3.6.1.4.1.4756.20.421.40.1.37 | Columnf1000EASX1FiberInfoSN2RemoteB | read-only | current | RemoteB device card port INFORemoteBOM S/N 2 |
| 1.3.6.1.4.1.4756.20.421.40.1.38 | Columnf1000EASX1FiberDDRemoteB | read-only | current | RemoteB device card fiber port Digital Diagnostic function: 0:No 1:Yes |
| 1.3.6.1.4.1.4756.20.421.40.1.39 | Columnf1000EASX1FiberDDVendorRemoteB | read-only | current | RemoteB device card fiber port D/D information: Vendor name |
| 1.3.6.1.4.1.4756.20.421.40.1.40 | Columnf1000EASX1FiberDDPartNoRemoteB | read-only | current | RemoteB device card fiber port D/D information: Vendor part number |
| 1.3.6.1.4.1.4756.20.421.40.1.41 | Columnf1000EASX1FiberDDVendorSNRemoteB | read-only | current | RemoteB device card fiber port D/D information: Vendor Serial Number |
| 1.3.6.1.4.1.4756.20.421.40.1.42 | Columnf1000EASX1FiberDDFiberTypeRemoteB | read-only | current | RemoteB device card fiber port D/D information: Fiber Type |
| 1.3.6.1.4.1.4756.20.421.40.1.43 | Columnf1000EASX1FiberDDWaveLenRemoteB | read-only | current | RemoteB device card fiber port D/D information: Wave length |
| 1.3.6.1.4.1.4756.20.421.40.1.44 | Columnf1000EASX1FiberDDWaveLen2RemoteB | read-only | current | RemoteB device card fiber port D/D information: Wave length 2 |
| 1.3.6.1.4.1.4756.20.421.40.1.45 | Columnf1000EASX1FiberDDLinkLenRemoteB | read-only | current | RemoteB device card fiber port D/D information: Link length |
| 1.3.6.1.4.1.4756.20.421.40.1.46 | Columnf1000EASX1FiberDDLenUnitRemoteB | read-only | current | RemoteB device card fiber port D/D information: Length Unit |
| 1.3.6.1.4.1.4756.20.421.40.1.47 | Columnf1000EASX1FiberDDStatusRemoteB | read-only | current | RemoteB device card fiber port D/D information: Status Support |
| 1.3.6.1.4.1.4756.20.421.40.1.48 | Columnf1000EASX1FiberDDRxSensRemoteB | read-only | current | RemoteB device card fiber port D/D information: Rx Sensitivity |
| 1.3.6.1.4.1.4756.20.421.40.1.49 | Columnf1000EASX1FiberDDTxPWRRemoteB | read-only | current | RemoteB device card fiber port D/D information: Tx power |
| 1.3.6.1.4.1.4756.20.421.40.1.50 | Columnf1000EASX1FiberDDRxPWRRemoteB | read-only | current | RemoteB device card fiber port D/D information: Rx power |
| 1.3.6.1.4.1.4756.20.421.40.1.51 | Columnf1000EASX1FiberDDTempRemoteB | read-only | current | RemoteB device card fiber port D/D information: Temperature in degree C |
| 1.3.6.1.4.1.4756.20.421.40.1.52 | Columnf1000EASX1FiberDDPWRMarginRemoteB | read-only | current | RemoteB device card fiber port D/D information: Power margin |
| 1.3.6.1.4.1.4756.20.421.40.1.53 | Columnf1000EASX1FiberDDPWRLossRemoteB | read-only | current | RemoteB device card fiber port D/D information: Power loss |
| 1.3.6.1.4.1.4756.20.421.40.1.54 | Columnf1000EASX1ClrRMONCntsRemoteB | read-write | current | Clear RemoteB device card RMON IN/OUT counters: 0:No action 1:Action |
| 1.3.6.1.4.1.4756.20.421.40.1.55 | Columnf1000EASX1FiberRMONInRemoteB | read-only | current | RemoteB device card port RMON IN counter. |
| 1.3.6.1.4.1.4756.20.421.40.1.56 | Columnf1000EASX1FiberRMONOutRemoteB | read-only | current | RemoteB device card port RMON OUT counter. |
| 1.3.6.1.4.1.4756.20.421.40.1.57 | Columnf1000EASX1UtpRMONInRemoteB | read-only | current | RemoteB device card port RMON IN counter. |
| 1.3.6.1.4.1.4756.20.421.40.1.58 | Columnf1000EASX1UtpRMONOutRemoteB | read-only | current | RemoteB device card port RMON OUT counter. |
| 1.3.6.1.4.1.4756.20.421.40.1.59 | Columnf1000EASX1ClrOAMCntsRemoteB | read-write | current | Clear RemoteB device card OAM counters: 0:No action 1:Action |
| 1.3.6.1.4.1.4756.20.421.40.1.60 | Columnf1000EASX1IpModeRemoteB | read-write | current | On Rack Ip Mode: 0:Enable 1:Disable |
| 1.3.6.1.4.1.4756.20.421.40.1.61 | Columnf1000EASX1OamChTxRemoteB | read-only | current | RemoteB device OAM Channel TX OAMPDU frame count |
| 1.3.6.1.4.1.4756.20.421.40.1.62 | Columnf1000EASX1OamChRxRemoteB | read-only | current | RemoteB device OAM Channel RX OAMPDU frame count |
| 1.3.6.1.4.1.4756.20.421.40.1.63 | Columnf1000EASX1OamInfoChTxRemoteB | read-only | current | RemoteB device OAM Channel TX Information OAMPDU frame count |
| 1.3.6.1.4.1.4756.20.421.40.1.64 | Columnf1000EASX1OamInfoChRxRemoteB | read-only | current | RemoteB device OAM Channel RX Information OAMPDU frame count |
| 1.3.6.1.4.1.4756.20.421.40.1.65 | Columnf1000EASX1OamEventChTxRemoteB | read-only | current | RemoteB device OAM Channel TX Event OAMPDU frame count |
| 1.3.6.1.4.1.4756.20.421.40.1.66 | Columnf1000EASX1OamUniEvtChRxRemoteB | read-only | current | RemoteB device OAM Channel RX Unique Event OAMPDU frame count |
| 1.3.6.1.4.1.4756.20.421.40.1.67 | Columnf1000EASX1OamDupEvtChRxRemoteB | read-only | current | RemoteB device OAM Channel RX Duplicate Event OAMPDU frame count |
| 1.3.6.1.4.1.4756.20.421.40.1.68 | Columnf1000EASX1OamLbChTxRemoteB | read-only | current | RemoteB device OAM Channel TX Loopback Control OAMPDU frame count |
| 1.3.6.1.4.1.4756.20.421.40.1.69 | Columnf1000EASX1OamLbChRxRemoteB | read-only | current | RemoteB device OAM Channel RX Loopback Control OAMPDU frame count |
| 1.3.6.1.4.1.4756.20.421.40.1.70 | Columnf1000EASX1OamVarReqChTxRemoteB | read-only | current | RemoteB device OAM Channel TX Variable Request OAMPDU frame count |
| 1.3.6.1.4.1.4756.20.421.40.1.71 | Columnf1000EASX1OamVarReqChRxRemoteB | read-only | current | RemoteB device OAM Channel RX Variable Request OAMPDU frame count |
| 1.3.6.1.4.1.4756.20.421.40.1.72 | Columnf1000EASX1OamVarRspChTxRemoteB | read-only | current | RemoteB device OAM Channel TX Variable Response OAMPDU frame count |
| 1.3.6.1.4.1.4756.20.421.40.1.73 | Columnf1000EASX1OamVarRspChRxRemoteB | read-only | current | RemoteB device OAM Channel RX Variable Response OAMPDU frame count |
| 1.3.6.1.4.1.4756.20.421.40.1.74 | Columnf1000EASX1OamOuiChTxRemoteB | read-only | current | RemoteB device OAM Channel TX OUI OAMPDU frame count |
| 1.3.6.1.4.1.4756.20.421.40.1.75 | Columnf1000EASX1OamOuiChRxRemoteB | read-only | current | RemoteB device OAM Channel RX OUI OAMPDU frame count |
| 1.3.6.1.4.1.4756.20.421.40.1.76 | Columnf1000EASX1OamUnknowChRxRemoteB | read-only | current | RemoteB device OAM Channel RX Unsupported OAMPDU frame count |
| 1.3.6.1.4.1.4756.20.421.40.1.77 | Columnf1000EASX1FiberSpeedRemoteB | read-only | current | RemoteB device Fiber speed : 0:1000 1:100 |
| 1.3.6.1.4.1.4756.20.421.40.1.78 | Columnf1000EASX1MacLearningRemoteB | read-write | current | RemoteB device Mac learning : 0:Disable 1:Enable |
| 1.3.6.1.4.1.4756.20.421.40.1.79 | Columnf1000EASX1Port1VIDRemoteB | read-write | current | RemoteB device Port 1 VID : |
| 1.3.6.1.4.1.4756.20.421.40.1.80 | Columnf1000EASX1Port2VIDRemoteB | read-write | current | RemoteB device Port 2 VID : |
| 1.3.6.1.4.1.4756.20.421.40.1.81 | Columnf1000EASX1Port1QinQRemoteB | read-write | current | RemoteB device Port 1 Q in Q Support : 1:Disable 2:Enable |
| 1.3.6.1.4.1.4756.20.421.40.1.82 | Columnf1000EASX1Port2QinQRemoteB | read-write | current | RemoteB device Port 2 Q in Q Support : 1:Disable 2:Enable |
| 1.3.6.1.4.1.4756.20.421.40.1.83 | Columnf1000EASX1VID1RemoteB | read-write | current | RemoteB device VID 1: |
| 1.3.6.1.4.1.4756.20.421.40.1.84 | Columnf1000EASX1VID2RemoteB | read-write | current | RemoteB device VID 2: |
| 1.3.6.1.4.1.4756.20.421.40.1.85 | Columnf1000EASX1VID3RemoteB | read-write | current | RemoteB device VID 3: |
| 1.3.6.1.4.1.4756.20.421.40.1.86 | Columnf1000EASX1VID4RemoteB | read-write | current | RemoteB device VID 4: |
| 1.3.6.1.4.1.4756.20.421.40.1.87 | Columnf1000EASX1VID5RemoteB | read-write | current | RemoteB device VID 5: |
| 1.3.6.1.4.1.4756.20.421.40.1.88 | Columnf1000EASX1VID6RemoteB | read-write | current | RemoteB device VID 6: |
| 1.3.6.1.4.1.4756.20.421.40.1.89 | Columnf1000EASX1VID7RemoteB | read-write | current | RemoteB device VID 7: |
| 1.3.6.1.4.1.4756.20.421.40.1.90 | Columnf1000EASX1VID8RemoteB | read-write | current | RemoteB device VID 8: |
| 1.3.6.1.4.1.4756.20.421.40.1.91 | Columnf1000EASX1VID9RemoteB | read-write | current | RemoteB device VID 9: |
| 1.3.6.1.4.1.4756.20.421.40.1.92 | Columnf1000EASX1VID10RemoteB | read-write | current | RemoteB device VID 10: |
| 1.3.6.1.4.1.4756.20.421.40.1.93 | Columnf1000EASX1VID11RemoteB | read-write | current | RemoteB device VID 11: |
| 1.3.6.1.4.1.4756.20.421.40.1.94 | Columnf1000EASX1VID12RemoteB | read-write | current | RemoteB device VID 12: |
| 1.3.6.1.4.1.4756.20.421.40.1.95 | Columnf1000EASX1VID13RemoteB | read-write | current | RemoteB device VID 13: |
| 1.3.6.1.4.1.4756.20.421.40.1.96 | Columnf1000EASX1VID14RemoteB | read-write | current | RemoteB device VID 14: |
| 1.3.6.1.4.1.4756.20.421.40.1.97 | Columnf1000EASX1VID15RemoteB | read-write | current | RemoteB device VID 15: |
| 1.3.6.1.4.1.4756.20.421.40.1.98 | Columnf1000EASX1VID16RemoteB | read-write | current | RemoteB device VID 16: |
| 1.3.6.1.4.1.4756.20.421.40.1.99 | Columnf1000EASX1Port1Member1RemoteB | read-write | current | RemoteB device card port 1 member: 0:Unmodify 1:Untagged 2:Tagged 3:Nonmember |
| 1.3.6.1.4.1.4756.20.421.40.1.100 | Columnf1000EASX1Port1Member2RemoteB | read-write | current | RemoteB device card port 1 member 2: 0:Unmodify 1:Untagged 2:Tagged 3:Nonmember |
| 1.3.6.1.4.1.4756.20.421.40.1.101 | Columnf1000EASX1Port1Member3RemoteB | read-write | current | RemoteB device card port 1 member 3: 0:Unmodify 1:Untagged 2:Tagged 3:Nonmember |
| 1.3.6.1.4.1.4756.20.421.40.1.102 | Columnf1000EASX1Port1Member4RemoteB | read-write | current | RemoteB device card port 1 member 4: 0:Unmodify 1:Untagged 2:Tagged 3:Nonmember |
| 1.3.6.1.4.1.4756.20.421.40.1.103 | Columnf1000EASX1Port1Member5RemoteB | read-write | current | RemoteB device card port 1 member 5: 0:Unmodify 1:Untagged 2:Tagged 3:Nonmember |
| 1.3.6.1.4.1.4756.20.421.40.1.104 | Columnf1000EASX1Port1Member6RemoteB | read-write | current | RemoteB device card port 1 member 6: 0:Unmodify 1:Untagged 2:Tagged 3:Nonmember |
| 1.3.6.1.4.1.4756.20.421.40.1.105 | Columnf1000EASX1Port1Member7RemoteB | read-write | current | RemoteB device card port 1 member 7: 0:Unmodify 1:Untagged 2:Tagged 3:Nonmember |
| 1.3.6.1.4.1.4756.20.421.40.1.106 | Columnf1000EASX1Port1Member8RemoteB | read-write | current | RemoteB device card port 1 member 8: 0:Unmodify 1:Untagged 2:Tagged 3:Nonmember |
| 1.3.6.1.4.1.4756.20.421.40.1.107 | Columnf1000EASX1Port1Member9RemoteB | read-write | current | RemoteB device card port 1 member 9: 0:Unmodify 1:Untagged 2:Tagged 3:Nonmember |
| 1.3.6.1.4.1.4756.20.421.40.1.108 | Columnf1000EASX1Port1Member10RemoteB | read-write | current | RemoteB device card port 1 member 10: 0:Unmodify 1:Untagged 2:Tagged 3:Nonmember |
| 1.3.6.1.4.1.4756.20.421.40.1.109 | Columnf1000EASX1Port1Member11RemoteB | read-write | current | RemoteB device card port 1 member 11: 0:Unmodify 1:Untagged 2:Tagged 3:Nonmember |
| 1.3.6.1.4.1.4756.20.421.40.1.110 | Columnf1000EASX1Port1Member12RemoteB | read-write | current | RemoteB device card port 1 member 12: 0:Unmodify 1:Untagged 2:Tagged 3:Nonmember |
| 1.3.6.1.4.1.4756.20.421.40.1.111 | Columnf1000EASX1Port1Member13RemoteB | read-write | current | RemoteB device card port 1 member 13: 0:Unmodify 1:Untagged 2:Tagged 3:Nonmember |
| 1.3.6.1.4.1.4756.20.421.40.1.112 | Columnf1000EASX1Port1Member14RemoteB | read-write | current | RemoteB device card port 1 member 14: 0:Unmodify 1:Untagged 2:Tagged 3:Nonmember |
| 1.3.6.1.4.1.4756.20.421.40.1.113 | Columnf1000EASX1Port1Member15RemoteB | read-write | current | RemoteB device card port 1 member 15: 0:Unmodify 1:Untagged 2:Tagged 3:Nonmember |
| 1.3.6.1.4.1.4756.20.421.40.1.114 | Columnf1000EASX1Port1Member16RemoteB | read-write | current | RemoteB device card port 1 member 16: 0:Unmodify 1:Untagged 2:Tagged 3:Nonmember |
| 1.3.6.1.4.1.4756.20.421.40.1.115 | Columnf1000EASX1Port2Member1RemoteB | read-write | current | RemoteB device card port 2 member: 0:Unmodify 1:Untagged 2:Tagged 3:Nonmember |
| 1.3.6.1.4.1.4756.20.421.40.1.116 | Columnf1000EASX1Port2Member2RemoteB | read-write | current | RemoteB device card port 2 member 2: 0:Unmodify 1:Untagged 2:Tagged 3:Nonmember |
| 1.3.6.1.4.1.4756.20.421.40.1.117 | Columnf1000EASX1Port2Member3RemoteB | read-write | current | RemoteB device card port 2 member 3: 0:Unmodify 1:Untagged 2:Tagged 3:Nonmember |
| 1.3.6.1.4.1.4756.20.421.40.1.118 | Columnf1000EASX1Port2Member4RemoteB | read-write | current | RemoteB device card port 2 member 4: 0:Unmodify 1:Untagged 2:Tagged 3:Nonmember |
| 1.3.6.1.4.1.4756.20.421.40.1.119 | Columnf1000EASX1Port2Member5RemoteB | read-write | current | RemoteB device card port 2 member 5: 0:Unmodify 1:Untagged 2:Tagged 3:Nonmember |
| 1.3.6.1.4.1.4756.20.421.40.1.120 | Columnf1000EASX1Port2Member6RemoteB | read-write | current | RemoteB device card port 2 member 6: 0:Unmodify 1:Untagged 2:Tagged 3:Nonmember |
| 1.3.6.1.4.1.4756.20.421.40.1.121 | Columnf1000EASX1Port2Member7RemoteB | read-write | current | RemoteB device card port 2 member 7: 0:Unmodify 1:Untagged 2:Tagged 3:Nonmember |
| 1.3.6.1.4.1.4756.20.421.40.1.122 | Columnf1000EASX1Port2Member8RemoteB | read-write | current | RemoteB device card port 2 member 8: 0:Unmodify 1:Untagged 2:Tagged 3:Nonmember |
| 1.3.6.1.4.1.4756.20.421.40.1.123 | Columnf1000EASX1Port2Member9RemoteB | read-write | current | RemoteB device card port 2 member 9: 0:Unmodify 1:Untagged 2:Tagged 3:Nonmember |
| 1.3.6.1.4.1.4756.20.421.40.1.124 | Columnf1000EASX1Port2Member10RemoteB | read-write | current | RemoteB device card port 2 member 10: 0:Unmodify 1:Untagged 2:Tagged 3:Nonmember |
| 1.3.6.1.4.1.4756.20.421.40.1.125 | Columnf1000EASX1Port2Member11RemoteB | read-write | current | RemoteB device card port 2 member 11: 0:Unmodify 1:Untagged 2:Tagged 3:Nonmember |
| 1.3.6.1.4.1.4756.20.421.40.1.126 | Columnf1000EASX1Port2Member12RemoteB | read-write | current | RemoteB device card port 2 member 12: 0:Unmodify 1:Untagged 2:Tagged 3:Nonmember |
| 1.3.6.1.4.1.4756.20.421.40.1.127 | Columnf1000EASX1Port2Member13RemoteB | read-write | current | RemoteB device card port 2 member 13: 0:Unmodify 1:Untagged 2:Tagged 3:Nonmember |
| 1.3.6.1.4.1.4756.20.421.40.1.128 | Columnf1000EASX1Port2Member14RemoteB | read-write | current | RemoteB device card port 2 member 14: 0:Unmodify 1:Untagged 2:Tagged 3:Nonmember |
| 1.3.6.1.4.1.4756.20.421.40.1.129 | Columnf1000EASX1Port2Member15RemoteB | read-write | current | RemoteB device card port 2 member 15: 0:Unmodify 1:Untagged 2:Tagged 3:Nonmember |
| 1.3.6.1.4.1.4756.20.421.40.1.130 | Columnf1000EASX1Port2Member16RemoteB | read-write | current | RemoteB device card port 2 member 16: 0:Unmodify 1:Untagged 2:Tagged 3:Nonmember |
| 1.3.6.1.4.1.4756.20.421.40.1.131 | Columnf1000EASX1IpAddressRemoteB | read-write | current | RemoteB device IP address |
| 1.3.6.1.4.1.4756.20.421.40.1.132 | Columnf1000EASX1NetMaskRemoteB | read-write | current | RemoteB device Netmask |
| 1.3.6.1.4.1.4756.20.421.40.1.133 | Columnf1000EASX1GateWayRemoteB | read-write | current | RemoteB device Gateway |
| 1.3.6.1.4.1.4756.20.421.40.1.134 | Columnf1000EASX1SetDefaultRemoteB | read-write | current | RemoteB device set to default |
| 1.3.6.1.4.1.4756.20.421.40.1.135 | Columnf1000EASX1ManagementVIDRemoteB | read-write | current | RemoteB device Management VID : |
| 1.3.6.1.4.1.4756.20.421.40.1.136 | Columnf1000EASX1TagTypeRemoteB | read-write | current | RemoteB device Tag Type (HEX) : |
| 1.3.6.1.4.1.4756.20.421.40.1.137 | Columnf1000EASX1FxLinkAlarmRemoteB | read-write | current | RemoteB device fiber link alarm 0:Disable 1:Enable |
| 1.3.6.1.4.1.4756.20.421.40.1.138 | Columnf1000EASX1UtpLinkAlarmRemoteB | read-write | current | RemoteB device utp link alarm 0:Disable 1:Enable |
| 1.3.6.1.4.1.4756.20.421.40.1.139 | Columnf1000EASX1RemoteTLPTRemoteB | read-write | current | RemoteB device Remote TLPT mode : 0:Disalbe 1:Remote |
| 1.3.6.1.4.1.4756.20.430 | Nodef4E1LocalCards | |||
| 1.3.6.1.4.1.4756.20.430.20 | Tablef4E1LocalTable | not-accessible | current | A list of local FRM220A-iMux4 series card entries. The number of entries is f5E1-No-L. |
| 1.3.6.1.4.1.4756.20.430.20.1 | Rowf4E1LocalEntry | not-accessible | current | An entry containing management information applicable to a particular local FRM220A-iMux4 series card. |
| 1.3.6.1.4.1.4756.20.430.20.1.1 | Columnfa4e1et100ChassisIndexLocal | read-only | current | A unique value for each card. It starts from 0 to 9 contiguously. |
| 1.3.6.1.4.1.4756.20.430.20.1.2 | Columnfa4e1et100SlotIndexLocal | read-only | current | A unique value for each card. It starts from 1 to 20 contiguously. |
| 1.3.6.1.4.1.4756.20.430.20.1.3 | Columnfa4e1et100CardHWVerLocal | read-only | current | iMux4(T/S) Series card hardware version x.xxx |
| 1.3.6.1.4.1.4756.20.430.20.1.4 | Columnfa4e1et100CardFWVerLocal | read-only | current | iMux4(T/S) Series card firmware version x.xxx |
| 1.3.6.1.4.1.4756.20.430.20.1.5 | Columnfa4e1et100CardCPLDVerLocal | read-only | current | iMux4(T/S) Series card CPLD version x.xxx |
| 1.3.6.1.4.1.4756.20.430.20.1.6 | Columnfa4e1et100CardFPGAVerLocal | read-only | current | iMux4(T/S) Series card FPGA version x.xxx |
| 1.3.6.1.4.1.4756.20.430.20.1.7 | Columnfa4e1et100ModelLocal | read-only | current | Card Type: 0:iMux4T 1:iMux4S |
| 1.3.6.1.4.1.4756.20.430.20.1.8 | Columnfa4e1et100SystemStatusLocal | read-only | current | iMux4(T/S) Series card system status: 0:Normal 1:Alarm |
| 1.3.6.1.4.1.4756.20.430.20.1.9 | Columnfa4e1et100DeviceActiveLocal | read-write | current | iMux4(T/S) Series card active: 0:Disable 1:Enable |
| 1.3.6.1.4.1.4756.20.430.20.1.10 | Columnfa4e1et100SetToDefaultLocal | read-write | current | iMux4(T/S) Series card port set to default: 0:Off 1:Trigger |
| 1.3.6.1.4.1.4756.20.430.20.1.11 | Columnfa4e1et100E1Ch1SingalLocal | read-only | current | iMux4(T/S) Series card E1 channel 1 signal status: 0:Singal Loss 1:Normal |
| 1.3.6.1.4.1.4756.20.430.20.1.12 | Columnfa4e1et100E1Ch2SingalLocal | read-only | current | iMux4(T/S) Series card E1 channel 2 signal status: 0:Singal Loss 1:Normal |
| 1.3.6.1.4.1.4756.20.430.20.1.13 | Columnfa4e1et100E1Ch3SingalLocal | read-only | current | iMux4(T/S) Series card E1 channel 3 signal status: 0:Singal Loss 1:Normal |
| 1.3.6.1.4.1.4756.20.430.20.1.14 | Columnfa4e1et100E1Ch4SingalLocal | read-only | current | iMux4(T/S) Series card E1 channel 4 signal status: 0:Singal Loss 1:Normal |
| 1.3.6.1.4.1.4756.20.430.20.1.15 | Columnfa4e1et100E1Ch1SyncLocal | read-only | current | iMux4(T/S) Series card E1 channel 1 sync status: 0:Sync Loss 1:Sync |
| 1.3.6.1.4.1.4756.20.430.20.1.16 | Columnfa4e1et100E1Ch2SyncLocal | read-only | current | iMux4(T/S) Series card E1 channel 2 sync status: 0:Sync Loss 1:Sync |
| 1.3.6.1.4.1.4756.20.430.20.1.17 | Columnfa4e1et100E1Ch3SyncLocal | read-only | current | iMux4(T/S) Series card E1 channel 3 sync status: 0:Sync Loss 1:Sync |
| 1.3.6.1.4.1.4756.20.430.20.1.18 | Columnfa4e1et100E1Ch4SyncLocal | read-only | current | iMux4(T/S) Series card E1 channel 4 sync status: 0:Sync Loss 1:Sync |
| 1.3.6.1.4.1.4756.20.430.20.1.19 | Columnfa4e1et100E1Ch1RecvAISLocal | read-only | current | iMux4(T/S) Series card E1 channel 1 receive AIS status: 0:No 1:Yes |
| 1.3.6.1.4.1.4756.20.430.20.1.20 | Columnfa4e1et100E1Ch2RecvAISLocal | read-only | current | iMux4(T/S) Series card E1 channel 2 receive AIS status: 0:No 1:Yes |
| 1.3.6.1.4.1.4756.20.430.20.1.21 | Columnfa4e1et100E1Ch3RecvAISLocal | read-only | current | iMux4(T/S) Series card E1 channel 3 receive AIS status: 0:No 1:Yes |
| 1.3.6.1.4.1.4756.20.430.20.1.22 | Columnfa4e1et100E1Ch4RecvAISLocal | read-only | current | iMux4(T/S) Series card E1 channel 4 receive AIS status: 0:No 1:Yes |
| 1.3.6.1.4.1.4756.20.430.20.1.23 | Columnfa4e1et100E1Ch1ConnTypeLocal | read-only | current | iMux4(T/S) Series card E1 channel 1 connector type: 0:RJ-48C 1:BNC |
| 1.3.6.1.4.1.4756.20.430.20.1.24 | Columnfa4e1et100E1Ch2ConnTypeLocal | read-only | current | iMux4(T/S) Series card E1 channel 2 connector type: 0:RJ-48C 1:BNC |
| 1.3.6.1.4.1.4756.20.430.20.1.25 | Columnfa4e1et100E1Ch3ConnTypeLocal | read-only | current | iMux4(T/S) Series card E1 channel 3 connector type: 0:RJ-48C 1:BNC |
| 1.3.6.1.4.1.4756.20.430.20.1.26 | Columnfa4e1et100E1Ch4ConnTypeLocal | read-only | current | iMux4(T/S) Series card E1 channel 4 connector type: 0:RJ-48C 1:BNC |
| 1.3.6.1.4.1.4756.20.430.20.1.27 | Columnfa4e1et100E1Ch1RAILocal | read-only | current | iMux4(T/S) Series card E1 channel 1 RAI status: 0:No 1:Yes |
| 1.3.6.1.4.1.4756.20.430.20.1.28 | Columnfa4e1et100E1Ch2RAILocal | read-only | current | iMux4(T/S) Series card E1 channel 2 RAI status: 0:No 1:Yes |
| 1.3.6.1.4.1.4756.20.430.20.1.29 | Columnfa4e1et100E1Ch3RAILocal | read-only | current | iMux4(T/S) Series card E1 channel 3 RAI status: 0:No 1:Yes |
| 1.3.6.1.4.1.4756.20.430.20.1.30 | Columnfa4e1et100E1Ch4RAILocal | read-only | current | iMux4(T/S) Series card E1 channel 4 RAI status: 0:No 1:Yes |
| 1.3.6.1.4.1.4756.20.430.20.1.31 | Columnfa4e1et100E1Ch1LOMFLocal | read-only | current | iMux4(T/S) Series card E1 channel 1 LOMF status: 0:No 1:Yes |
| 1.3.6.1.4.1.4756.20.430.20.1.32 | Columnfa4e1et100E1Ch2LOMFLocal | read-only | current | iMux4(T/S) Series card E1 channel 2 LOMF status: 0:No 1:Yes |
| 1.3.6.1.4.1.4756.20.430.20.1.33 | Columnfa4e1et100E1Ch3LOMFLocal | read-only | current | iMux4(T/S) Series card E1 channel 3 LOMF status: 0:No 1:Yes |
| 1.3.6.1.4.1.4756.20.430.20.1.34 | Columnfa4e1et100E1Ch4LOMFLocal | read-only | current | iMux4(T/S) Series card E1 channel 4 LOMF status: 0:No 1:Yes |
| 1.3.6.1.4.1.4756.20.430.20.1.35 | Columnfa4e1et100E1Ch1ActiveLocal | read-only | current | iMux4(T/S) Series card E1 channel 1 active status: 0:Inactive 1:Active |
| 1.3.6.1.4.1.4756.20.430.20.1.36 | Columnfa4e1et100E1Ch2ActiveLocal | read-only | current | iMux4(T/S) Series card E1 channel 2 active status: 0:Inactive 1:Active |
| 1.3.6.1.4.1.4756.20.430.20.1.37 | Columnfa4e1et100E1Ch3ActiveLocal | read-only | current | iMux4(T/S) Series card E1 channel 3 active status: 0:Inactive 1:Active |
| 1.3.6.1.4.1.4756.20.430.20.1.38 | Columnfa4e1et100E1Ch4ActiveLocal | read-only | current | iMux4(T/S) Series card E1 channel 4 active status: 0:Inactive 1:Active |
| 1.3.6.1.4.1.4756.20.430.20.1.39 | Columnfa4e1et100E1Ch1LoopBackLocal | read-write | current | iMux4(T/S) Series card port E1 channel 1 loop back: 0:Off 2:RLB (Max used 3 channels) |
| 1.3.6.1.4.1.4756.20.430.20.1.40 | Columnfa4e1et100E1Ch2LoopBackLocal | read-write | current | iMux4(T/S) Series card port E1 channel 2 loop back: 0:Off 2:RLB (Max used 3 channels) |
| 1.3.6.1.4.1.4756.20.430.20.1.41 | Columnfa4e1et100E1Ch3LoopBackLocal | read-write | current | iMux4(T/S) Series card port E1 channel 3 loop back: 0:Off 2:RLB (Max used 3 channels) |
| 1.3.6.1.4.1.4756.20.430.20.1.42 | Columnfa4e1et100E1Ch4LoopBackLocal | read-write | current | iMux4(T/S) Series card port E1 channel 4 loop back: 0:Off 2:RLB (Max used 3 channels) |
| 1.3.6.1.4.1.4756.20.430.20.1.43 | Columnfa4e1et100FxLinkLocal | read-only | current | 5E1-ET100S Series card Fiber siganl detect status: 0:Down or Fiber unplugged 1:Up or Singal detected |
| 1.3.6.1.4.1.4756.20.430.20.1.44 | Columnfa4e1et100FxLaserLocal | read-only | current | 5E1-ET100S Series card laser status: 0:Normal 1:Error |
| 1.3.6.1.4.1.4756.20.430.20.1.45 | Columnfa4e1et100FxActiveLocal | read-write | current | 5E1-ET100S Series card Fiber active: 0:Inactive 1:Active |
| 1.3.6.1.4.1.4756.20.430.20.1.46 | Columnfa4e1et100FxLaserOutputLocal | read-write | current | 5E1-ET100S Series card laser output: 0:disable 1:Enable |
| 1.3.6.1.4.1.4756.20.430.20.1.47 | Columnfa4e1et100FxOpModeLocal | read-write | current | 5E1-ET100S Series card operation mode: 0:Switch 1:Convert |
| 1.3.6.1.4.1.4756.20.430.20.1.48 | Columnfa4e1et100UtpLinkLocal | read-only | current | 5E1-ET100T Series card UTP link status: 0:Link Down 1:Link Up |
| 1.3.6.1.4.1.4756.20.430.20.1.49 | Columnfa4e1et100UtpStatusLocal | read-only | current | 5E1-ET100T Series card UTP link mode status: 0:None, Maybe link down 1:Link at 10Mbps, Half duplex 2:Link at 10Mbps, Full duplex 3:Link at 100Mbps, Half duplex… |
| 1.3.6.1.4.1.4756.20.430.20.1.50 | Columnfa4e1et100UtpFlowCtrlStsLocal | read-only | current | 5E1-ET100T Series card UTP flow control status: 0:Disable 1:Enable |
| 1.3.6.1.4.1.4756.20.430.20.1.51 | Columnfa4e1et100UtpModeLocal | read-write | current | 5E1-ET100T Series card UTP mode: 0:Disable 1:Enable and autoNegotiation 3:Enable and force to 10Mbps, Half duplex 4:Enable and force to 10Mbps, Full duplex 5:E… |
| 1.3.6.1.4.1.4756.20.430.20.1.52 | Columnfa4e1et100UtpFlowCtrlLocal | read-write | current | 5E1-ET100T Series card UTP flow control: 0:Disable 1:Enable |
| 1.3.6.1.4.1.4756.20.430.20.1.53 | Columnfa4e1et100SpeedLimitLocal | read-write | current | iMux4(T/S) Series card speed limit: Limited = this value * 32Kbps, this value is restricted to 0 ~ 3125, 0 to disable |
| 1.3.6.1.4.1.4756.20.430.20.1.54 | Columnfa4e1et100VlanAwareLocal | read-write | current | iMux4(T/S) Series card 802.1q VLAN tag aware: 0:Disable 1:Enable |
| 1.3.6.1.4.1.4756.20.430.20.1.55 | Columnfa4e1et100VlanIDLocal | read-write | current | iMux4(T/S) Series card VLAN ID: The ID is restricted to 1 ~ 4094 |
| 1.3.6.1.4.1.4756.20.430.20.1.56 | Columnfa4e1et100RemoteDeviceLocal | read-only | current | FRM220A-5E1 Series card remote device status: 0:Link Down 1:Link Up |
| 1.3.6.1.4.1.4756.20.430.20.1.57 | Columnfa4e1et100RemotePowerLocal | read-only | current | iMux4(T/S) Series card remote device power status: 0:Normal 1:Power off |
| 1.3.6.1.4.1.4756.20.430.20.1.58 | Columnfa4e1et100TimingSourceLocal | read-write | current | iMux4(T/S) Series card clock: 0:Internal oscillatro 1:Recovery from E1 channel 1 2:Recovery from E1 channel 2 3:Recovery from E1 channel 3 4:Recovery from E1 c… |
| 1.3.6.1.4.1.4756.20.430.20.1.59 | Columnfa4e1et100FCSofGFPLocal | read-write | current | iMux4(T/S) Series card FCS of GFP: 0:Disable 1:Enable |
| 1.3.6.1.4.1.4756.20.430.20.1.60 | Columnfa4e1et100AutoChAdjustLocal | read-write | current | iMux4(T/S) Series card auto channel Bdjust: 0:Disable 1:Enable |
| 1.3.6.1.4.1.4756.20.430.20.1.61 | Columnfa4e1et100PayloadScrambleLocal | read-write | current | iMux4(T/S) Series card payload scramble: 0:Disable 1:Enable |
| 1.3.6.1.4.1.4756.20.430.20.1.62 | Columnfa4e1et100FailoverLocal | read-write | current | iMux4(T/S) Series card failover: 0:Disable 1:Enable |
| 1.3.6.1.4.1.4756.20.430.20.1.63 | Columnfa4e1et100LOMLocal | read-only | current | iMux4(T/S) Series card LOM status: 0:No 1:Yes |
| 1.3.6.1.4.1.4756.20.430.20.1.64 | Columnfa4e1et100SQMLocal | read-only | current | iMux4(T/S) Series card SQM status: 0:No 1:Yes |
| 1.3.6.1.4.1.4756.20.430.20.1.65 | Columnfa4e1et100CRCLocal | read-only | current | iMux4(T/S) Series card CRC status: 0:No 1:Yes |
| 1.3.6.1.4.1.4756.20.430.20.1.66 | Columnfa4e1et100LOALocal | read-only | current | iMux4(T/S) Series card LOA status: 0:No 1:Yes |
| 1.3.6.1.4.1.4756.20.430.20.1.67 | Columnfa4e1et100LFDLocal | read-only | current | iMux4(T/S) Series card LFD status: 0:No 1:Yes |
| 1.3.6.1.4.1.4756.20.430.20.1.68 | Columnfa4e1et100DDTOLocal | read-only | current | iMux4(T/S) Series card DDTO status: 0:No 1:Yes |
| 1.3.6.1.4.1.4756.20.430.20.1.69 | Columnfa4e1et100VcatMember1Local | read-write | current | iMux4(T/S) Series card VACT member 0: 0:Disable 1:Enable |
| 1.3.6.1.4.1.4756.20.430.20.1.70 | Columnfa4e1et100VcatMember2Local | read-write | current | iMux4(T/S) Series card VACT member 1: 0:Disable 1:Enable |
| 1.3.6.1.4.1.4756.20.430.20.1.71 | Columnfa4e1et100VcatMember3Local | read-write | current | iMux4(T/S) Series card VACT member 3: 0:Disable 1:Enable |
| 1.3.6.1.4.1.4756.20.430.20.1.72 | Columnfa4e1et100VcatMember4Local | read-write | current | iMux4(T/S) Series card VACT member 4: 0:Disable 1:Enable |
| 1.3.6.1.4.1.4756.20.430.20.1.73 | Columnfa4e1et100SnmpChannel1Local | read-write | current | iMux4(T/S) Series card SNMP channel 0: 0:No use 1:Use |
| 1.3.6.1.4.1.4756.20.430.20.1.74 | Columnfa4e1et100SnmpChannel2Local | read-write | current | iMux4(T/S) Series card SNMP channel 1: 0:No use 1:Use |
| 1.3.6.1.4.1.4756.20.430.20.1.75 | Columnfa4e1et100SnmpChannel3Local | read-write | current | iMux4(T/S) Series card SNMP channel 3: 0:No use 1:Use |
| 1.3.6.1.4.1.4756.20.430.20.1.76 | Columnfa4e1et100SnmpChannel4Local | read-write | current | iMux4(T/S) Series card SNMP channel 4: 0:No use 1:Use |
| 1.3.6.1.4.1.4756.20.430.20.1.77 | Columnfa4e1et100ErrSecLocal | read-only | current | iMux4(T/S) Series card, errored seconds of BERT result. |
| 1.3.6.1.4.1.4756.20.430.20.1.78 | Columnfa4e1et100ErrFreeSecLocal | read-only | current | iMux4(T/S) Series card, errored free seconds of BERT result. |
| 1.3.6.1.4.1.4756.20.430.20.1.79 | Columnfa4e1et100ServErrSecLocal | read-only | current | iMux4(T/S) Series card, severely errored seconds of BERT result. |
| 1.3.6.1.4.1.4756.20.430.20.1.80 | Columnfa4e1et100BertFunctionLocal | read-write | current | iMux4(T/S) Series card bert function: 0:Disable 1:Enable |
| 1.3.6.1.4.1.4756.20.430.20.1.81 | Columnfa4e1et100ClrBertDataLocal | read-write | current | iMux4(T/S) Series card bert data clear: 0:Normal 1:Clear |
| 1.3.6.1.4.1.4756.20.430.20.1.82 | Columnfa4e1et100BertE1ChannelLocal | read-write | current | iMux4(T/S) Series card bert E1 channel number: 0:E1 channel 1 1:E1 channel 2 2:E1 channel 3 3:E1 channel 4 |
| 1.3.6.1.4.1.4756.20.430.20.1.83 | Columnfa4e1et100RmonFunctionLocal | read-write | current | iMux4(T/S) Series RMON function : 0:Disable 1:Enable |
| 1.3.6.1.4.1.4756.20.430.20.1.84 | Columnfa4e1et100RmonTxLocal | read-only | current | iMux4(T/S) Series card RMON Tx counter. |
| 1.3.6.1.4.1.4756.20.430.20.1.85 | Columnfa4e1et100RmonRxLocal | read-only | current | iMux4(T/S) Series card RMON Rx counter. |
| 1.3.6.1.4.1.4756.20.430.20.1.86 | Columnfa4e1et100ClrRmonTxLocal | read-write | current | iMux4(T/S) Series card clear RMON Tx counter: 0:Normal 1:Clear |
| 1.3.6.1.4.1.4756.20.430.20.1.87 | Columnfa4e1et100ClrRmonRxLocal | read-write | current | iMux4(T/S) Series card clear RMON Rx counter: 0:Normal 1:Clear |
| 1.3.6.1.4.1.4756.20.430.20.1.88 | Columnfa4e1et100SfpLocal | read-only | current | iMux4(T/S) Series card, SFP existed: 0:No 1:Yes |
| 1.3.6.1.4.1.4756.20.430.20.1.89 | Columnfa4e1et100SfpVendorLocal | read-only | current | iMux4(T/S) Series card, Vendor name of SFP. |
| 1.3.6.1.4.1.4756.20.430.20.1.90 | Columnfa4e1et100SfpPartNoLocal | read-only | current | iMux4(T/S) Series card, Vendor part number of SFP. |
| 1.3.6.1.4.1.4756.20.430.20.1.91 | Columnfa4e1et100SfpFiberTypeLocal | read-only | current | iMux4(T/S) Series card, Fiber Type of SFP. |
| 1.3.6.1.4.1.4756.20.430.20.1.92 | Columnfa4e1et100SfpTxWaveLenLocal | read-only | current | iMux4(T/S) Series card, Tx Wave length of SFP. |
| 1.3.6.1.4.1.4756.20.430.20.1.93 | Columnfa4e1et100SfpRxWaveLenLocal | read-only | current | iMux4(T/S) Series card, Rx Wave length of SFP. |
| 1.3.6.1.4.1.4756.20.430.20.1.94 | Columnfa4e1et100SfpLinkLenLocal | read-only | current | iMux4(T/S) Series card, Link length of SFP. |
| 1.3.6.1.4.1.4756.20.430.20.1.95 | Columnfa4e1et100SfpModelIDLocal | read-only | current | iMux4(T/S) Series card, model ID of SFP. |
| 1.3.6.1.4.1.4756.20.430.20.1.96 | Columnfa4e1et100SfpVersionLocal | read-only | current | iMux4(T/S) Series card, the version of SFP. |
| 1.3.6.1.4.1.4756.20.430.20.1.97 | Columnfa4e1et100SfpModelTypeLocal | read-only | current | iMux4(T/S) Series card, model type of SFP. |
| 1.3.6.1.4.1.4756.20.430.20.1.98 | Columnfa4e1et100DDInformationLocal | read-only | current | iMux4(T/S) Series card, D/D information of SFP Supported: 0:No, 1:Yes |
| 1.3.6.1.4.1.4756.20.430.20.1.99 | Columnfa4e1et100DDRxSensLocal | read-only | current | iMux4(T/S) Series card, Sensitivity of D/D information. |
| 1.3.6.1.4.1.4756.20.430.20.1.100 | Columnfa4e1et100DDTxPowerLocal | read-only | current | iMux4(T/S) Series card, Tx power of D/D information. |
| 1.3.6.1.4.1.4756.20.430.20.1.101 | Columnfa4e1et100DDRxPowerLocal | read-only | current | iMux4(T/S) Series card, Rx power of D/D information. |
| 1.3.6.1.4.1.4756.20.430.20.1.102 | Columnfa4e1et100DDTempLocal | read-only | current | iMux4(T/S) Series card, Temperature of D/D information in degree C. |
| 1.3.6.1.4.1.4756.20.430.20.1.103 | Columnfa4e1et100DDBiasLocal | read-only | current | iMux4(T/S) Series card, BIAS of D/D information. |
| 1.3.6.1.4.1.4756.20.430.20.1.104 | Columnfa4e1et100DDVoltageLocal | read-only | current | iMux4(T/S) Series card, Voltage of D/D information. |
| 1.3.6.1.4.1.4756.20.430.20.1.105 | Columnfa4e1et100ChannelDefectLocal | read-write | current | iMux4(T/S) Series card Channel Defect: 0:Disable 4:1E-4 6:1E-6 |
| 1.3.6.1.4.1.4756.20.430.20.1.106 | Columnfa4e1et100LoopDetectionLocal | read-write | current | iMux4(T/S) Series card Loop Detection: 0:Disable 1:Enable |
| 1.3.6.1.4.1.4756.20.430.20.1.107 | Columnfa4e1et100LoopCh1Local | read-only | current | iMux4(T/S) Series card E1 channel 1 Loop Check State: 0:No 1:Yes |
| 1.3.6.1.4.1.4756.20.430.20.1.108 | Columnfa4e1et100LoopCh2Local | read-only | current | iMux4(T/S) Series card E1 channel 2 Loop Check State: 0:No 1:Yes |
| 1.3.6.1.4.1.4756.20.430.20.1.109 | Columnfa4e1et100LoopCh3Local | read-only | current | iMux4(T/S) Series card E1 channel 3 Loop Check State: 0:No 1:Yes |
| 1.3.6.1.4.1.4756.20.430.20.1.110 | Columnfa4e1et100LoopCh4Local | read-only | current | iMux4(T/S) Series card E1 channel 4 Loop Check State: 0:No 1:Yes |
| 1.3.6.1.4.1.4756.20.430.20.1.111 | Columnfa4e1et100DefectCh1Local | read-only | current | iMux4(T/S) Series card E1 channel 1 Defect Status: 0:No 1:Yes |
| 1.3.6.1.4.1.4756.20.430.20.1.112 | Columnfa4e1et100DefectCh2Local | read-only | current | iMux4(T/S) Series card E1 channel 2 Defect Status: 0:No 1:Yes |
| 1.3.6.1.4.1.4756.20.430.20.1.113 | Columnfa4e1et100DefectCh3Local | read-only | current | iMux4(T/S) Series card E1 channel 3 Defect Status: 0:No 1:Yes |
| 1.3.6.1.4.1.4756.20.430.20.1.114 | Columnfa4e1et100DefectCh4Local | read-only | current | iMux4(T/S) Series card E1 channel 4 Defect Status: 0:No 1:Yes |
| 1.3.6.1.4.1.4756.20.430.20.1.115 | Columnfa4e1et100FxSignalLocal | read-only | current | iMux4(T/S) Series card Fiber signal detect(SD): 0:Fiber unplugged 1:Signal detected |
| 1.3.6.1.4.1.4756.20.430.20.1.116 | Columnfa4e1et100PortResetLocal | read-write | current | iMux4(T/S) Series card Port Reset: 0:Off 1:Action |
| 1.3.6.1.4.1.4756.20.430.20.1.117 | Columnfa4e1et100VLANModeLocal | read-write | current | iMux4(T/S) Series card VLAN mode: 0:MODE2 1:MODE1 |
| 1.3.6.1.4.1.4756.20.430.20.1.118 | Columnfa4e1et100ETagSelectEntryLocal | read-write | current | iMux4(T/S) Series card ETag select entry: |
| 1.3.6.1.4.1.4756.20.430.20.1.119 | Columnfa4e1et100ETagMethodLocal | read-write | current | iMux4(T/S) Series card ETag Method: 0: Intouch 1: Add Tag 2: Remove Tag |
| 1.3.6.1.4.1.4756.20.430.20.1.120 | Columnfa4e1et100VLANTableVID1Local | read-write | current | iMux4(T/S) Series card VLAN Table: VLAN ID1 |
| 1.3.6.1.4.1.4756.20.430.20.1.121 | Columnfa4e1et100VLANTableVID2Local | read-write | current | iMux4(T/S) Series card VLAN Table: VLAN ID2 |
| 1.3.6.1.4.1.4756.20.430.20.1.122 | Columnfa4e1et100VLANTableVID3Local | read-write | current | iMux4(T/S) Series card VLAN Table: VLAN ID3 |
| 1.3.6.1.4.1.4756.20.430.20.1.123 | Columnfa4e1et100VLANTableVID4Local | read-write | current | iMux4(T/S) Series card VLAN Table: VLAN ID4 |
| 1.3.6.1.4.1.4756.20.430.20.1.124 | Columnfa4e1et100VLANTableVID5Local | read-write | current | iMux4(T/S) Series card VLAN Table: VLAN ID5 |
| 1.3.6.1.4.1.4756.20.430.20.1.125 | Columnfa4e1et100VLANTableVID6Local | read-write | current | iMux4(T/S) Series card VLAN Table: VLAN ID6 |
| 1.3.6.1.4.1.4756.20.430.20.1.126 | Columnfa4e1et100VLANTableVID7Local | read-write | current | iMux4(T/S) Series card VLAN Table: VLAN ID7 |
| 1.3.6.1.4.1.4756.20.430.20.1.127 | Columnfa4e1et100VLANTableVID8Local | read-write | current | iMux4(T/S) Series card VLAN Table: VLAN ID8 |
| 1.3.6.1.4.1.4756.20.430.20.1.128 | Columnfa4e1et100VLANTableVID9Local | read-write | current | iMux4(T/S) Series card VLAN Table: VLAN ID9 |
| 1.3.6.1.4.1.4756.20.430.20.1.129 | Columnfa4e1et100VLANTableVID10Local | read-write | current | iMux4(T/S) Series card VLAN Table: VLAN ID10 |
| 1.3.6.1.4.1.4756.20.430.20.1.130 | Columnfa4e1et100VLANTableVID11Local | read-write | current | iMux4(T/S) Series card VLAN Table: VLAN ID11 |
| 1.3.6.1.4.1.4756.20.430.20.1.131 | Columnfa4e1et100VLANTableVID12Local | read-write | current | iMux4(T/S) Series card VLAN Table: VLAN ID12 |
| 1.3.6.1.4.1.4756.20.430.20.1.132 | Columnfa4e1et100VLANTableVID13Local | read-write | current | iMux4(T/S) Series card VLAN Table: VLAN ID13 |
| 1.3.6.1.4.1.4756.20.430.20.1.133 | Columnfa4e1et100VLANTableVID14Local | read-write | current | iMux4(T/S) Series card VLAN Table: VLAN ID14 |
| 1.3.6.1.4.1.4756.20.430.20.1.134 | Columnfa4e1et100VLANTableVID15Local | read-write | current | iMux4(T/S) Series card VLAN Table: VLAN ID15 |
| 1.3.6.1.4.1.4756.20.430.20.1.135 | Columnfa4e1et100VLANTableVID16Local | read-write | current | iMux4(T/S) Series card VLAN Table: VLAN ID16 |
| 1.3.6.1.4.1.4756.20.431 | Nodef4E1RemoteCards | |||
| 1.3.6.1.4.1.4756.20.431.20 | Tablef4E1RemoteTable | not-accessible | current | A list of Remote FRM220A-iMux4 series card entries. The number of entries is f5E1-No-L. |
| 1.3.6.1.4.1.4756.20.431.20.1 | Rowf4E1RemoteEntry | not-accessible | current | An entry containing management information applicable to a particular Remote FRM220A-iMux4 series card. |
| 1.3.6.1.4.1.4756.20.431.20.1.1 | Columnfa4e1et100ChassisIndexRemote | read-only | current | A unique value for each card. It starts from 0 to 9 contiguously. |
| 1.3.6.1.4.1.4756.20.431.20.1.2 | Columnfa4e1et100SlotIndexRemote | read-only | current | A unique value for each card. It starts from 1 to 20 contiguously. |
| 1.3.6.1.4.1.4756.20.431.20.1.3 | Columnfa4e1et100CardHWVerRemote | read-only | current | iMux4(T/S) Series card hardware version x.xxx |
| 1.3.6.1.4.1.4756.20.431.20.1.4 | Columnfa4e1et100CardFWVerRemote | read-only | current | iMux4(T/S) Series card firmware version x.xxx |
| 1.3.6.1.4.1.4756.20.431.20.1.5 | Columnfa4e1et100CardCPLDVerRemote | read-only | current | iMux4(T/S) Series card CPLD version x.xxx |
| 1.3.6.1.4.1.4756.20.431.20.1.6 | Columnfa4e1et100CardFPGAVerRemote | read-only | current | iMux4(T/S) Series card FPGA version x.xxx |
| 1.3.6.1.4.1.4756.20.431.20.1.7 | Columnfa4e1et100ModelRemote | read-only | current | Card Type: 0:iMux4T 1:iMux4S |
| 1.3.6.1.4.1.4756.20.431.20.1.8 | Columnfa4e1et100SystemStatusRemote | read-only | current | iMux4(T/S) Series card system status: 0:Normal 1:Alarm |
| 1.3.6.1.4.1.4756.20.431.20.1.9 | Columnfa4e1et100DeviceActiveRemote | read-only | current | iMux4(T/S) Series card active: 0:Disable 1:Enable |
| 1.3.6.1.4.1.4756.20.431.20.1.10 | Columnfa4e1et100SetToDefaultRemote | read-write | current | iMux4(T/S) Series card port set to default: 0:Off 1:Trigger |
| 1.3.6.1.4.1.4756.20.431.20.1.11 | Columnfa4e1et100E1Ch1SingalRemote | read-only | current | iMux4(T/S) Series card E1 channel 1 signal status: 0:Singal Loss 1:Normal |
| 1.3.6.1.4.1.4756.20.431.20.1.12 | Columnfa4e1et100E1Ch2SingalRemote | read-only | current | iMux4(T/S) Series card E1 channel 2 signal status: 0:Singal Loss 1:Normal |
| 1.3.6.1.4.1.4756.20.431.20.1.13 | Columnfa4e1et100E1Ch3SingalRemote | read-only | current | iMux4(T/S) Series card E1 channel 3 signal status: 0:Singal Loss 1:Normal |
| 1.3.6.1.4.1.4756.20.431.20.1.14 | Columnfa4e1et100E1Ch4SingalRemote | read-only | current | iMux4(T/S) Series card E1 channel 4 signal status: 0:Singal Loss 1:Normal |
| 1.3.6.1.4.1.4756.20.431.20.1.15 | Columnfa4e1et100E1Ch1SyncRemote | read-only | current | iMux4(T/S) Series card E1 channel 1 sync status: 0:Sync Loss 1:Sync |
| 1.3.6.1.4.1.4756.20.431.20.1.16 | Columnfa4e1et100E1Ch2SyncRemote | read-only | current | iMux4(T/S) Series card E1 channel 2 sync status: 0:Sync Loss 1:Sync |
| 1.3.6.1.4.1.4756.20.431.20.1.17 | Columnfa4e1et100E1Ch3SyncRemote | read-only | current | iMux4(T/S) Series card E1 channel 3 sync status: 0:Sync Loss 1:Sync |
| 1.3.6.1.4.1.4756.20.431.20.1.18 | Columnfa4e1et100E1Ch4SyncRemote | read-only | current | iMux4(T/S) Series card E1 channel 4 sync status: 0:Sync Loss 1:Sync |
| 1.3.6.1.4.1.4756.20.431.20.1.19 | Columnfa4e1et100E1Ch1RecvAISRemote | read-only | current | iMux4(T/S) Series card E1 channel 1 receive AIS status: 0:No 1:Yes |
| 1.3.6.1.4.1.4756.20.431.20.1.20 | Columnfa4e1et100E1Ch2RecvAISRemote | read-only | current | iMux4(T/S) Series card E1 channel 2 receive AIS status: 0:No 1:Yes |
| 1.3.6.1.4.1.4756.20.431.20.1.21 | Columnfa4e1et100E1Ch3RecvAISRemote | read-only | current | iMux4(T/S) Series card E1 channel 3 receive AIS status: 0:No 1:Yes |
| 1.3.6.1.4.1.4756.20.431.20.1.22 | Columnfa4e1et100E1Ch4RecvAISRemote | read-only | current | iMux4(T/S) Series card E1 channel 4 receive AIS status: 0:No 1:Yes |
| 1.3.6.1.4.1.4756.20.431.20.1.23 | Columnfa4e1et100E1Ch1ConnTypeRemote | read-only | current | iMux4(T/S) Series card E1 channel 1 connector type: 0:RJ-48C 1:BNC |
| 1.3.6.1.4.1.4756.20.431.20.1.24 | Columnfa4e1et100E1Ch2ConnTypeRemote | read-only | current | iMux4(T/S) Series card E1 channel 2 connector type: 0:RJ-48C 1:BNC |
| 1.3.6.1.4.1.4756.20.431.20.1.25 | Columnfa4e1et100E1Ch3ConnTypeRemote | read-only | current | iMux4(T/S) Series card E1 channel 3 connector type: 0:RJ-48C 1:BNC |
| 1.3.6.1.4.1.4756.20.431.20.1.26 | Columnfa4e1et100E1Ch4ConnTypeRemote | read-only | current | iMux4(T/S) Series card E1 channel 4 connector type: 0:RJ-48C 1:BNC |
| 1.3.6.1.4.1.4756.20.431.20.1.27 | Columnfa4e1et100E1Ch1RAIRemote | read-only | current | iMux4(T/S) Series card E1 channel 1 RAI status: 0:No 1:Yes |
| 1.3.6.1.4.1.4756.20.431.20.1.28 | Columnfa4e1et100E1Ch2RAIRemote | read-only | current | iMux4(T/S) Series card E1 channel 2 RAI status: 0:No 1:Yes |
| 1.3.6.1.4.1.4756.20.431.20.1.29 | Columnfa4e1et100E1Ch3RAIRemote | read-only | current | iMux4(T/S) Series card E1 channel 3 RAI status: 0:No 1:Yes |
| 1.3.6.1.4.1.4756.20.431.20.1.30 | Columnfa4e1et100E1Ch4RAIRemote | read-only | current | iMux4(T/S) Series card E1 channel 4 RAI status: 0:No 1:Yes |
| 1.3.6.1.4.1.4756.20.431.20.1.31 | Columnfa4e1et100E1Ch1LOMFRemote | read-only | current | iMux4(T/S) Series card E1 channel 1 LOMF status: 0:No 1:Yes |
| 1.3.6.1.4.1.4756.20.431.20.1.32 | Columnfa4e1et100E1Ch2LOMFRemote | read-only | current | iMux4(T/S) Series card E1 channel 2 LOMF status: 0:No 1:Yes |
| 1.3.6.1.4.1.4756.20.431.20.1.33 | Columnfa4e1et100E1Ch3LOMFRemote | read-only | current | iMux4(T/S) Series card E1 channel 3 LOMF status: 0:No 1:Yes |
| 1.3.6.1.4.1.4756.20.431.20.1.34 | Columnfa4e1et100E1Ch4LOMFRemote | read-only | current | iMux4(T/S) Series card E1 channel 4 LOMF status: 0:No 1:Yes |
| 1.3.6.1.4.1.4756.20.431.20.1.35 | Columnfa4e1et100E1Ch1ActiveRemote | read-only | current | iMux4(T/S) Series card E1 channel 1 active status: 0:Inactive 1:Active |
| 1.3.6.1.4.1.4756.20.431.20.1.36 | Columnfa4e1et100E1Ch2ActiveRemote | read-only | current | iMux4(T/S) Series card E1 channel 2 active status: 0:Inactive 1:Active |
| 1.3.6.1.4.1.4756.20.431.20.1.37 | Columnfa4e1et100E1Ch3ActiveRemote | read-only | current | iMux4(T/S) Series card E1 channel 3 active status: 0:Inactive 1:Active |
| 1.3.6.1.4.1.4756.20.431.20.1.38 | Columnfa4e1et100E1Ch4ActiveRemote | read-only | current | iMux4(T/S) Series card E1 channel 4 active status: 0:Inactive 1:Active |
| 1.3.6.1.4.1.4756.20.431.20.1.39 | Columnfa4e1et100E1Ch1LoopBackRemote | read-write | current | iMux4(T/S) Series card port E1 channel 1 loop back: 0:Off 2:RLB (Max used 3 channels) |
| 1.3.6.1.4.1.4756.20.431.20.1.40 | Columnfa4e1et100E1Ch2LoopBackRemote | read-write | current | iMux4(T/S) Series card port E1 channel 2 loop back: 0:Off 2:RLB (Max used 3 channels) |
| 1.3.6.1.4.1.4756.20.431.20.1.41 | Columnfa4e1et100E1Ch3LoopBackRemote | read-write | current | iMux4(T/S) Series card port E1 channel 3 loop back: 0:Off 2:RLB (Max used 3 channels) |
| 1.3.6.1.4.1.4756.20.431.20.1.42 | Columnfa4e1et100E1Ch4LoopBackRemote | read-write | current | iMux4(T/S) Series card port E1 channel 4 loop back: 0:Off 2:RLB (Max used 3 channels) |
| 1.3.6.1.4.1.4756.20.431.20.1.43 | Columnfa4e1et100FxLinkRemote | read-only | current | 5E1-ET100S Series card Fiber siganl detect status: 0:Down or Fiber unplugged 1:Up or Singal detected |
| 1.3.6.1.4.1.4756.20.431.20.1.44 | Columnfa4e1et100FxLaserRemote | read-only | current | 5E1-ET100S Series card laser status: 0:Normal 1:Error |
| 1.3.6.1.4.1.4756.20.431.20.1.45 | Columnfa4e1et100FxActiveRemote | read-write | current | 5E1-ET100S Series card Fiber active: 0:Inactive 1:Active |
| 1.3.6.1.4.1.4756.20.431.20.1.46 | Columnfa4e1et100FxLaserOutputRemote | read-write | current | 5E1-ET100S Series card laser output: 0:disable 1:Enable |
| 1.3.6.1.4.1.4756.20.431.20.1.47 | Columnfa4e1et100FxOpModeRemote | read-write | current | 5E1-ET100S Series card operation mode: 0:Switch 1:Convert |
| 1.3.6.1.4.1.4756.20.431.20.1.48 | Columnfa4e1et100UtpLinkRemote | read-only | current | 5E1-ET100T Series card UTP link status: 0:Link Down 1:Link Up |
| 1.3.6.1.4.1.4756.20.431.20.1.49 | Columnfa4e1et100UtpStatusRemote | read-only | current | 5E1-ET100T Series card UTP link mode status: 0:None, Maybe link down 1:Link at 10Mbps, Half duplex 2:Link at 10Mbps, Full duplex 3:Link at 100Mbps, Half duplex… |
| 1.3.6.1.4.1.4756.20.431.20.1.50 | Columnfa4e1et100UtpFlowCtrlStsRemote | read-only | current | 5E1-ET100T Series card UTP flow control status: 0:Disable 1:Enable |
| 1.3.6.1.4.1.4756.20.431.20.1.51 | Columnfa4e1et100UtpModeRemote | read-write | current | 5E1-ET100T Series card UTP mode: 0:Disable 1:Enable and autoNegotiation 3:Enable and force to 10Mbps, Half duplex 4:Enable and force to 10Mbps, Full duplex 5:E… |
| 1.3.6.1.4.1.4756.20.431.20.1.52 | Columnfa4e1et100UtpFlowCtrlRemote | read-write | current | 5E1-ET100T Series card UTP flow control: 0:Disable 1:Enable |
| 1.3.6.1.4.1.4756.20.431.20.1.53 | Columnfa4e1et100SpeedLimitRemote | read-write | current | iMux4(T/S) Series card speed limit: Limited = this value * 32Kbps, this value is restricted to 0 ~ 3125, 0 to disable |
| 1.3.6.1.4.1.4756.20.431.20.1.54 | Columnfa4e1et100VlanAwareRemote | read-write | current | iMux4(T/S) Series card 802.1q VLAN tag aware: 0:Disable 1:Enable |
| 1.3.6.1.4.1.4756.20.431.20.1.55 | Columnfa4e1et100VlanIDRemote | read-write | current | iMux4(T/S) Series card VLAN ID: The ID is restricted to 1 ~ 4094 |
| 1.3.6.1.4.1.4756.20.431.20.1.56 | Columnfa4e1et100RemoteDeviceRemote | read-only | current | FRM220A-5E1 Series card remote device status: 0:Link Down 1:Link Up |
| 1.3.6.1.4.1.4756.20.431.20.1.57 | Columnfa4e1et100RemotePowerRemote | read-only | current | iMux4(T/S) Series card remote device power status: 0:Normal 1:Power off |
| 1.3.6.1.4.1.4756.20.431.20.1.58 | Columnfa4e1et100TimingSourceRemote | read-write | current | iMux4(T/S) Series card clock: 0:Internal oscillatro 1:Recovery from E1 channel 1 2:Recovery from E1 channel 2 3:Recovery from E1 channel 3 4:Recovery from E1 c… |
| 1.3.6.1.4.1.4756.20.431.20.1.59 | Columnfa4e1et100FCSofGFPRemote | read-write | current | iMux4(T/S) Series card FCS of GFP: 0:Disable 1:Enable |
| 1.3.6.1.4.1.4756.20.431.20.1.60 | Columnfa4e1et100AutoChAdjustRemote | read-write | current | iMux4(T/S) Series card auto channel Bdjust: 0:Disable 1:Enable |
| 1.3.6.1.4.1.4756.20.431.20.1.61 | Columnfa4e1et100PayloadScrambleRemote | read-write | current | iMux4(T/S) Series card payload scramble: 0:Disable 1:Enable |
| 1.3.6.1.4.1.4756.20.431.20.1.62 | Columnfa4e1et100FailoverRemote | read-write | current | iMux4(T/S) Series card failover: 0:Disable 1:Enable |
| 1.3.6.1.4.1.4756.20.431.20.1.63 | Columnfa4e1et100LOMRemote | read-only | current | iMux4(T/S) Series card LOM status: 0:No 1:Yes |
| 1.3.6.1.4.1.4756.20.431.20.1.64 | Columnfa4e1et100SQMRemote | read-only | current | iMux4(T/S) Series card SQM status: 0:No 1:Yes |
| 1.3.6.1.4.1.4756.20.431.20.1.65 | Columnfa4e1et100CRCRemote | read-only | current | iMux4(T/S) Series card CRC status: 0:No 1:Yes |
| 1.3.6.1.4.1.4756.20.431.20.1.66 | Columnfa4e1et100LOARemote | read-only | current | iMux4(T/S) Series card LOA status: 0:No 1:Yes |
| 1.3.6.1.4.1.4756.20.431.20.1.67 | Columnfa4e1et100LFDRemote | read-only | current | iMux4(T/S) Series card LFD status: 0:No 1:Yes |
| 1.3.6.1.4.1.4756.20.431.20.1.68 | Columnfa4e1et100DDTORemote | read-only | current | iMux4(T/S) Series card DDTO status: 0:No 1:Yes |
| 1.3.6.1.4.1.4756.20.431.20.1.69 | Columnfa4e1et100VcatMember1Remote | read-write | current | iMux4(T/S) Series card VACT member 0: 0:Disable 1:Enable |
| 1.3.6.1.4.1.4756.20.431.20.1.70 | Columnfa4e1et100VcatMember2Remote | read-write | current | iMux4(T/S) Series card VACT member 1: 0:Disable 1:Enable |
| 1.3.6.1.4.1.4756.20.431.20.1.71 | Columnfa4e1et100VcatMember3Remote | read-write | current | iMux4(T/S) Series card VACT member 3: 0:Disable 1:Enable |
| 1.3.6.1.4.1.4756.20.431.20.1.72 | Columnfa4e1et100VcatMember4Remote | read-write | current | iMux4(T/S) Series card VACT member 4: 0:Disable 1:Enable |
| 1.3.6.1.4.1.4756.20.431.20.1.73 | Columnfa4e1et100SnmpChannel1Remote | read-write | current | iMux4(T/S) Series card SNMP channel 0: 0:No use 1:Use |
| 1.3.6.1.4.1.4756.20.431.20.1.74 | Columnfa4e1et100SnmpChannel2Remote | read-write | current | iMux4(T/S) Series card SNMP channel 1: 0:No use 1:Use |
| 1.3.6.1.4.1.4756.20.431.20.1.75 | Columnfa4e1et100SnmpChannel3Remote | read-write | current | iMux4(T/S) Series card SNMP channel 3: 0:No use 1:Use |
| 1.3.6.1.4.1.4756.20.431.20.1.76 | Columnfa4e1et100SnmpChannel4Remote | read-write | current | iMux4(T/S) Series card SNMP channel 4: 0:No use 1:Use |
| 1.3.6.1.4.1.4756.20.431.20.1.77 | Columnfa4e1et100ErrSecRemote | read-only | current | iMux4(T/S) Series card, errored seconds of BERT result. |
| 1.3.6.1.4.1.4756.20.431.20.1.78 | Columnfa4e1et100ErrFreeSecRemote | read-only | current | iMux4(T/S) Series card, errored free seconds of BERT result. |
| 1.3.6.1.4.1.4756.20.431.20.1.79 | Columnfa4e1et100ServErrSecRemote | read-only | current | iMux4(T/S) Series card, severely errored seconds of BERT result. |
| 1.3.6.1.4.1.4756.20.431.20.1.80 | Columnfa4e1et100BertFunctionRemote | read-write | current | iMux4(T/S) Series card bert function: 0:Disable 1:Enable |
| 1.3.6.1.4.1.4756.20.431.20.1.81 | Columnfa4e1et100ClrBertDataRemote | read-write | current | iMux4(T/S) Series card bert data clear: 0:Normal 1:Clear |
| 1.3.6.1.4.1.4756.20.431.20.1.82 | Columnfa4e1et100BertE1ChannelRemote | read-write | current | iMux4(T/S) Series card bert E1 channel number: 0:E1 channel 1 1:E1 channel 2 2:E1 channel 3 3:E1 channel 4 |
| 1.3.6.1.4.1.4756.20.431.20.1.83 | Columnfa4e1et100RmonFunctionRemote | read-write | current | iMux4(T/S) Series RMON function : 0:Disable 1:Enable |
| 1.3.6.1.4.1.4756.20.431.20.1.84 | Columnfa4e1et100RmonTxRemote | read-only | current | iMux4(T/S) Series card RMON Tx counter. |
| 1.3.6.1.4.1.4756.20.431.20.1.85 | Columnfa4e1et100RmonRxRemote | read-only | current | iMux4(T/S) Series card RMON Rx counter. |
| 1.3.6.1.4.1.4756.20.431.20.1.86 | Columnfa4e1et100ClrRmonTxRemote | read-write | current | iMux4(T/S) Series card clear RMON Tx counter: 0:Normal 1:Clear |
| 1.3.6.1.4.1.4756.20.431.20.1.87 | Columnfa4e1et100ClrRmonRxRemote | read-write | current | iMux4(T/S) Series card clear RMON Rx counter: 0:Normal 1:Clear |
| 1.3.6.1.4.1.4756.20.431.20.1.88 | Columnfa4e1et100SfpRemote | read-only | current | iMux4(T/S) Series card, SFP existed: 0:No 1:Yes |
| 1.3.6.1.4.1.4756.20.431.20.1.89 | Columnfa4e1et100SfpVendorRemote | read-only | current | iMux4(T/S) Series card, Vendor name of SFP. |
| 1.3.6.1.4.1.4756.20.431.20.1.90 | Columnfa4e1et100SfpPartNoRemote | read-only | current | iMux4(T/S) Series card, Vendor part number of SFP. |
| 1.3.6.1.4.1.4756.20.431.20.1.91 | Columnfa4e1et100SfpFiberTypeRemote | read-only | current | iMux4(T/S) Series card, Fiber Type of SFP. |
| 1.3.6.1.4.1.4756.20.431.20.1.92 | Columnfa4e1et100SfpTxWaveLenRemote | read-only | current | iMux4(T/S) Series card, Tx Wave length of SFP. |
| 1.3.6.1.4.1.4756.20.431.20.1.93 | Columnfa4e1et100SfpRxWaveLenRemote | read-only | current | iMux4(T/S) Series card, Rx Wave length of SFP. |
| 1.3.6.1.4.1.4756.20.431.20.1.94 | Columnfa4e1et100SfpLinkLenRemote | read-only | current | iMux4(T/S) Series card, Link length of SFP. |
| 1.3.6.1.4.1.4756.20.431.20.1.95 | Columnfa4e1et100SfpModelIDRemote | read-only | current | iMux4(T/S) Series card, model ID of SFP. |
| 1.3.6.1.4.1.4756.20.431.20.1.96 | Columnfa4e1et100SfpVersionRemote | read-only | current | iMux4(T/S) Series card, the version of SFP. |
| 1.3.6.1.4.1.4756.20.431.20.1.97 | Columnfa4e1et100SfpModelTypeRemote | read-only | current | iMux4(T/S) Series card, model type of SFP. |
| 1.3.6.1.4.1.4756.20.431.20.1.98 | Columnfa4e1et100DDInformationRemote | read-only | current | iMux4(T/S) Series card, D/D information of SFP Supported: 0:No, 1:Yes |
| 1.3.6.1.4.1.4756.20.431.20.1.99 | Columnfa4e1et100DDRxSensRemote | read-only | current | iMux4(T/S) Series card, Sensitivity of D/D information. |
| 1.3.6.1.4.1.4756.20.431.20.1.100 | Columnfa4e1et100DDTxPowerRemote | read-only | current | iMux4(T/S) Series card, Tx power of D/D information. |
| 1.3.6.1.4.1.4756.20.431.20.1.101 | Columnfa4e1et100DDRxPowerRemote | read-only | current | iMux4(T/S) Series card, Rx power of D/D information. |
| 1.3.6.1.4.1.4756.20.431.20.1.102 | Columnfa4e1et100DDTempRemote | read-only | current | iMux4(T/S) Series card, Temperature of D/D information in degree C. |
| 1.3.6.1.4.1.4756.20.431.20.1.103 | Columnfa4e1et100DDBiasRemote | read-only | current | iMux4(T/S) Series card, BIAS of D/D information. |
| 1.3.6.1.4.1.4756.20.431.20.1.104 | Columnfa4e1et100DDVoltageRemote | read-only | current | iMux4(T/S) Series card, Voltage of D/D information. |
| 1.3.6.1.4.1.4756.20.431.20.1.105 | Columnfa4e1et100ChannelDefectRemote | read-write | current | iMux4(T/S) Series card Channel Defect: 0:Disable 4:1E-4 6:1E-6 |
| 1.3.6.1.4.1.4756.20.431.20.1.106 | Columnfa4e1et100LoopDetectionRemote | read-write | current | iMux4(T/S) Series card Loop Detection: 0:Disable 1:Enable |
| 1.3.6.1.4.1.4756.20.431.20.1.107 | Columnfa4e1et100LoopCh1Remote | read-only | current | iMux4(T/S) Series card E1 channel 1 Loop Check State: 0:No 1:Yes |
| 1.3.6.1.4.1.4756.20.431.20.1.108 | Columnfa4e1et100LoopCh2Remote | read-only | current | iMux4(T/S) Series card E1 channel 2 Loop Check State: 0:No 1:Yes |
| 1.3.6.1.4.1.4756.20.431.20.1.109 | Columnfa4e1et100LoopCh3Remote | read-only | current | iMux4(T/S) Series card E1 channel 3 Loop Check State: 0:No 1:Yes |
| 1.3.6.1.4.1.4756.20.431.20.1.110 | Columnfa4e1et100LoopCh4Remote | read-only | current | iMux4(T/S) Series card E1 channel 4 Loop Check State: 0:No 1:Yes |
| 1.3.6.1.4.1.4756.20.431.20.1.111 | Columnfa4e1et100DefectCh1Remote | read-only | current | iMux4(T/S) Series card E1 channel 1 Defect Status: 0:No 1:Yes |
| 1.3.6.1.4.1.4756.20.431.20.1.112 | Columnfa4e1et100DefectCh2Remote | read-only | current | iMux4(T/S) Series card E1 channel 2 Defect Status: 0:No 1:Yes |
| 1.3.6.1.4.1.4756.20.431.20.1.113 | Columnfa4e1et100DefectCh3Remote | read-only | current | iMux4(T/S) Series card E1 channel 3 Defect Status: 0:No 1:Yes |
| 1.3.6.1.4.1.4756.20.431.20.1.114 | Columnfa4e1et100DefectCh4Remote | read-only | current | iMux4(T/S) Series card E1 channel 4 Defect Status: 0:No 1:Yes |
| 1.3.6.1.4.1.4756.20.431.20.1.115 | Columnfa4e1et100FxSignalRemote | read-only | current | iMux4(T/S) Series card Fiber signal detect(SD): 0:Fiber unplugged 1:Signal detected |
| 1.3.6.1.4.1.4756.20.431.20.1.116 | Columnfa4e1et100PortResetRemote | read-write | current | iMux4(T/S) Series card Port Reset: 0:Off 1:Action |
| 1.3.6.1.4.1.4756.20.431.20.1.117 | Columnfa4e1et100VLANModeRemote | read-write | current | iMux4(T/S) Series card VLAN mode: 0:MODE2 1:MODE1 |
| 1.3.6.1.4.1.4756.20.431.20.1.118 | Columnfa4e1et100ETagSelectEntryRemote | read-write | current | iMux4(T/S) Series card ETag select entry: |
| 1.3.6.1.4.1.4756.20.431.20.1.119 | Columnfa4e1et100ETagMethodRemote | read-write | current | iMux4(T/S) Series card ETag Method: 0: Intouch 1: Add Tag 2: Remove Tag |
| 1.3.6.1.4.1.4756.20.431.20.1.120 | Columnfa4e1et100VLANTableVID1Remote | read-write | current | iMux4(T/S) Series card VLAN Table: VLAN ID1 |
| 1.3.6.1.4.1.4756.20.431.20.1.121 | Columnfa4e1et100VLANTableVID2Remote | read-write | current | iMux4(T/S) Series card VLAN Table: VLAN ID2 |
| 1.3.6.1.4.1.4756.20.431.20.1.122 | Columnfa4e1et100VLANTableVID3Remote | read-write | current | iMux4(T/S) Series card VLAN Table: VLAN ID3 |
| 1.3.6.1.4.1.4756.20.431.20.1.123 | Columnfa4e1et100VLANTableVID4Remote | read-write | current | iMux4(T/S) Series card VLAN Table: VLAN ID4 |
| 1.3.6.1.4.1.4756.20.431.20.1.124 | Columnfa4e1et100VLANTableVID5Remote | read-write | current | iMux4(T/S) Series card VLAN Table: VLAN ID5 |
| 1.3.6.1.4.1.4756.20.431.20.1.125 | Columnfa4e1et100VLANTableVID6Remote | read-write | current | iMux4(T/S) Series card VLAN Table: VLAN ID6 |
| 1.3.6.1.4.1.4756.20.431.20.1.126 | Columnfa4e1et100VLANTableVID7Remote | read-write | current | iMux4(T/S) Series card VLAN Table: VLAN ID7 |
| 1.3.6.1.4.1.4756.20.431.20.1.127 | Columnfa4e1et100VLANTableVID8Remote | read-write | current | iMux4(T/S) Series card VLAN Table: VLAN ID8 |
| 1.3.6.1.4.1.4756.20.431.20.1.128 | Columnfa4e1et100VLANTableVID9Remote | read-write | current | iMux4(T/S) Series card VLAN Table: VLAN ID9 |
| 1.3.6.1.4.1.4756.20.431.20.1.129 | Columnfa4e1et100VLANTableVID10Remote | read-write | current | iMux4(T/S) Series card VLAN Table: VLAN ID10 |
| 1.3.6.1.4.1.4756.20.431.20.1.130 | Columnfa4e1et100VLANTableVID11Remote | read-write | current | iMux4(T/S) Series card VLAN Table: VLAN ID11 |
| 1.3.6.1.4.1.4756.20.431.20.1.131 | Columnfa4e1et100VLANTableVID12Remote | read-write | current | iMux4(T/S) Series card VLAN Table: VLAN ID12 |
| 1.3.6.1.4.1.4756.20.431.20.1.132 | Columnfa4e1et100VLANTableVID13Remote | read-write | current | iMux4(T/S) Series card VLAN Table: VLAN ID13 |
| 1.3.6.1.4.1.4756.20.431.20.1.133 | Columnfa4e1et100VLANTableVID14Remote | read-write | current | iMux4(T/S) Series card VLAN Table: VLAN ID14 |
| 1.3.6.1.4.1.4756.20.431.20.1.134 | Columnfa4e1et100VLANTableVID15Remote | read-write | current | iMux4(T/S) Series card VLAN Table: VLAN ID15 |
| 1.3.6.1.4.1.4756.20.431.20.1.135 | Columnfa4e1et100VLANTableVID16Remote | read-write | current | iMux4(T/S) Series card VLAN Table: VLAN ID16 |
| 1.3.6.1.4.1.4756.20.440 | NodeeddLocalCards | |||
| 1.3.6.1.4.1.4756.20.440.20 | TableeddLocalTable | not-accessible | current | A list of Local FRM220-EDD series card entries. |
| 1.3.6.1.4.1.4756.20.440.20.1 | RoweddLocalEntry | not-accessible | current | An entry containing management information applicable to a particular FRM220-EDD series card. |
| 1.3.6.1.4.1.4756.20.440.20.1.1 | ColumneddChassisIndexLocal | read-only | current | A unique value for each card. It starts from 0 to 9 contiguously. |
| 1.3.6.1.4.1.4756.20.440.20.1.2 | ColumneddSlotIndexLocal | read-only | current | A unique value for each card. It starts from 1 to 20 contiguously. |
| 1.3.6.1.4.1.4756.20.440.20.1.3 | ColumneddCardHWVerLocal | read-only | current | EDD Series card hardware version x.xxx |
| 1.3.6.1.4.1.4756.20.440.20.1.4 | ColumneddCardFWVerLocal | read-only | current | EDD Series card firmware version x.xxx |
| 1.3.6.1.4.1.4756.20.440.20.1.5 | ColumneddCardCPLDVerLocal | read-only | current | EDD Series card CPLD version x.xxx |
| 1.3.6.1.4.1.4756.20.440.20.1.6 | ColumneddCardFPGAVerLocal | read-only | current | EDD Series card FPGA version x.xxx |
| 1.3.6.1.4.1.4756.20.440.20.1.7 | ColumneddModelLocal | read-only | current | Card Type: 0:MX210 1:MSW202 |
| 1.3.6.1.4.1.4756.20.440.20.1.8 | ColumneddPort1LinkstsLocal | read-only | current | EDD Series card Port1 link status: 0:Link down 1:Link up |
| 1.3.6.1.4.1.4756.20.440.20.1.9 | ColumneddPort1SpeedstsLocal | read-only | current | EDD Series card Port1 speed status 10Base-T 100Base-Tx 1000Base-Tx 2.5G |
| 1.3.6.1.4.1.4756.20.440.20.1.10 | ColumneddPort1DuplexstsLocal | read-only | current | EDD Series card Port1 duplex status 0: Half 1: Full |
| 1.3.6.1.4.1.4756.20.440.20.1.11 | ColumneddPort1RxPausestsLocal | read-only | current | EDD Series card Port1 rx pause status 0: No 1: Yes |
| 1.3.6.1.4.1.4756.20.440.20.1.12 | ColumneddPort1TxPausestsLocal | read-only | current | EDD Series card Port1 tx pause status 0: No 1: Yes |
| 1.3.6.1.4.1.4756.20.440.20.1.13 | ColumneddPort2LinkstsLocal | read-only | current | EDD Series card Port2 link status: 0:Link down 1:Link up |
| 1.3.6.1.4.1.4756.20.440.20.1.14 | ColumneddPort2SpeedstsLocal | read-only | current | EDD Series card Port2 speed status 10Base-T 100Base-Tx 1000Base-Tx 2.5G |
| 1.3.6.1.4.1.4756.20.440.20.1.15 | ColumneddPort2DuplexstsLocal | read-only | current | EDD Series card Port2 duplex status 0: Half 1: Full |
| 1.3.6.1.4.1.4756.20.440.20.1.16 | ColumneddPort2RxPausestsLocal | read-only | current | EDD Series card Port2 rx pause status 0: No 1: Yes |
| 1.3.6.1.4.1.4756.20.440.20.1.17 | ColumneddPort2TxPausestsLocal | read-only | current | EDD Series card Port2 tx pause status 0: No 1: Yes |
| 1.3.6.1.4.1.4756.20.440.20.1.18 | ColumneddPort3LinkstsLocal | read-only | current | EDD Series card Port3 link status: 0:Link down 1:Link up |
| 1.3.6.1.4.1.4756.20.440.20.1.19 | ColumneddPort3SpeedstsLocal | read-only | current | EDD Series card Port3 speed status 10Base-T 100Base-Tx 1000Base-Tx |
| 1.3.6.1.4.1.4756.20.440.20.1.20 | ColumneddPort3DuplexstsLocal | read-only | current | EDD Series card Port3 duplex status 0: Half 1: Full |
| 1.3.6.1.4.1.4756.20.440.20.1.21 | ColumneddPort3RxPausestsLocal | read-only | current | EDD Series card Port3 rx pause status 0: No 1: Yes |
| 1.3.6.1.4.1.4756.20.440.20.1.22 | ColumneddPort3TxPausestsLocal | read-only | current | EDD Series card Port3 tx pause status 0: No 1: Yes |
| 1.3.6.1.4.1.4756.20.440.20.1.23 | ColumneddPort4LinkstsLocal | read-only | current | EDD Series card Port4 link status: 0:Link down 1:Link up |
| 1.3.6.1.4.1.4756.20.440.20.1.24 | ColumneddPort4SpeedstsLocal | read-only | current | EDD Series card Port4 speed status 10Base-T 100Base-Tx 1000Base-Tx |
| 1.3.6.1.4.1.4756.20.440.20.1.25 | ColumneddPort4DuplexstsLocal | read-only | current | EDD Series card Port4 duplex status 0: Half 1: Full |
| 1.3.6.1.4.1.4756.20.440.20.1.26 | ColumneddPort4RxPausestsLocal | read-only | current | EDD Series card Port4 rx pause status 0: No 1: Yes |
| 1.3.6.1.4.1.4756.20.440.20.1.27 | ColumneddPort4TxPausestsLocal | read-only | current | EDD Series card Port4 tx pause status 0: No 1: Yes |
| 1.3.6.1.4.1.4756.20.440.20.1.28 | ColumneddPort1SpeedConfLocal | read-write | current | EDD Series card Port1 speed config 0: disable 1: auto 2: 100M FDX 3: 1G FDX 4: 2.5G FDX |
| 1.3.6.1.4.1.4756.20.440.20.1.29 | ColumneddPort1flowConrolLocal | read-write | current | EDD Series card Port1 flow control config 0: no 1: yes |
| 1.3.6.1.4.1.4756.20.440.20.1.30 | ColumneddPort1MaxFrameLocal | read-write | current | EDD Series card Port1 max frame config |
| 1.3.6.1.4.1.4756.20.440.20.1.31 | ColumneddPort2SpeedConfLocal | read-write | current | EDD Series card Port2 speed config 0: disable 1: auto 2: 100M FDX 3: 1G FDX 4: 2.5G FDX |
| 1.3.6.1.4.1.4756.20.440.20.1.32 | ColumneddPort2flowConrolLocal | read-write | current | EDD Series card Port2 flow control config 0: no 1: yes |
| 1.3.6.1.4.1.4756.20.440.20.1.33 | ColumneddPort2MaxFrameLocal | read-write | current | EDD Series card Port2 max frame config |
| 1.3.6.1.4.1.4756.20.440.20.1.34 | ColumneddPort3SpeedConfLocal | read-write | current | EDD Series card Port3 speed config 0: disable 1: auto 2: 10M HDX 3: 10M FDX 4: 100M HDX 5: 100M FDX 6: 1G FDX |
| 1.3.6.1.4.1.4756.20.440.20.1.35 | ColumneddPort3flowConrolLocal | read-write | current | EDD Series card Port3 flow control config 0: no 1: yes |
| 1.3.6.1.4.1.4756.20.440.20.1.36 | ColumneddPort3MaxFrameLocal | read-write | current | EDD Series card Port3 max frame config |
| 1.3.6.1.4.1.4756.20.440.20.1.37 | ColumneddPort3CollisionModeLocal | read-write | current | EDD Series card Port3 collision mode config.(MSW202 only) 0: Discard 1: Restart |
| 1.3.6.1.4.1.4756.20.440.20.1.38 | ColumneddPort4SpeedConfLocal | read-write | current | EDD Series card Port4 speed config 0: disable 1: auto 2: 10M HDX 3: 10M FDX 4: 100M HDX 5: 100M FDX 6: 1G FDX |
| 1.3.6.1.4.1.4756.20.440.20.1.39 | ColumneddPort4flowConrolLocal | read-write | current | EDD Series card Port4 flow control config 0: no 1: yes |
| 1.3.6.1.4.1.4756.20.440.20.1.40 | ColumneddPort4MaxFrameLocal | read-write | current | EDD Series card Port4 max frame config |
| 1.3.6.1.4.1.4756.20.440.20.1.41 | ColumneddPort4CollisionModeLocal | read-write | current | EDD Series card Port4 collision mode config 0: Discard 1: Restart |
| 1.3.6.1.4.1.4756.20.440.20.1.42 | ColumneddSaveStartupCongLocal | read-write | current | EDD Series card save start-up config 0: OFF 1: Action |
| 1.3.6.1.4.1.4756.20.440.20.1.43 | ColumneddPortResetLocal | read-write | current | EDD Series card port reset 0: OFF 1: Action |
| 1.3.6.1.4.1.4756.20.440.20.1.44 | ColumneddSetDefaultLocal | read-write | current | EDD Series card set to default config 0: OFF 1: Action |
| 1.3.6.1.4.1.4756.20.440.20.1.45 | ColumneddMuxModeLocal | read-write | current | EDD Series card Mux mode (MX210 only) 0: Disable 1: Switch 2: Isolate 3: VLAN |
| 1.3.6.1.4.1.4756.20.440.20.1.46 | ColumneddPort1PacketsRxLocal | read-only | current | EDD Series card port1 traffic overview:: Packets Rx |
| 1.3.6.1.4.1.4756.20.440.20.1.47 | ColumneddPort1PacketsTxLocal | read-only | current | EDD Series card port1 traffic overview:: Packets Tx |
| 1.3.6.1.4.1.4756.20.440.20.1.48 | ColumneddPort1BytesRxLocal | read-only | current | EDD Series card port1 traffic overview:: Bytes Rx |
| 1.3.6.1.4.1.4756.20.440.20.1.49 | ColumneddPort1BytesTxLocal | read-only | current | EDD Series card port1 traffic overview:: Bytes Tx |
| 1.3.6.1.4.1.4756.20.440.20.1.50 | ColumneddPort1ErrorsRxLocal | read-only | current | EDD Series card port1 traffic overview:: Errors Rx |
| 1.3.6.1.4.1.4756.20.440.20.1.51 | ColumneddPort1ErrorsTxLocal | read-only | current | EDD Series card port1 traffic overview:: Errors Tx |
| 1.3.6.1.4.1.4756.20.440.20.1.52 | ColumneddPort1DropsRxLocal | read-only | current | EDD Series card port1 traffic overview:: Drops Rx |
| 1.3.6.1.4.1.4756.20.440.20.1.53 | ColumneddPort1DropsTxLocal | read-only | current | EDD Series card port1 traffic overview:: Drops Tx |
| 1.3.6.1.4.1.4756.20.440.20.1.54 | ColumneddPort1FilteredRxLocal | read-only | current | EDD Series card port1 traffic overview:: Filtered Rx |
| 1.3.6.1.4.1.4756.20.440.20.1.55 | ColumneddPort2PacketsRxLocal | read-only | current | EDD Series card port2 traffic overview:: Packets Rx |
| 1.3.6.1.4.1.4756.20.440.20.1.56 | ColumneddPort2PacketsTxLocal | read-only | current | EDD Series card port2 traffic overview:: Packets Tx |
| 1.3.6.1.4.1.4756.20.440.20.1.57 | ColumneddPort2BytesRxLocal | read-only | current | EDD Series card port2 traffic overview:: Bytes Rx |
| 1.3.6.1.4.1.4756.20.440.20.1.58 | ColumneddPort2BytesTxLocal | read-only | current | EDD Series card port2 traffic overview:: Bytes Tx |
| 1.3.6.1.4.1.4756.20.440.20.1.59 | ColumneddPort2ErrorsRxLocal | read-only | current | EDD Series card port2 traffic overview:: Errors Rx |
| 1.3.6.1.4.1.4756.20.440.20.1.60 | ColumneddPort2ErrorsTxLocal | read-only | current | EDD Series card port2 traffic overview:: Errors Tx |
| 1.3.6.1.4.1.4756.20.440.20.1.61 | ColumneddPort2DropsRxLocal | read-only | current | EDD Series card port2 traffic overview:: Drops Rx |
| 1.3.6.1.4.1.4756.20.440.20.1.62 | ColumneddPort2DropsTxLocal | read-only | current | EDD Series card port2 traffic overview:: Drops Tx |
| 1.3.6.1.4.1.4756.20.440.20.1.63 | ColumneddPort2FilteredRxLocal | read-only | current | EDD Series card port2 traffic overview:: Filtered Rx |
| 1.3.6.1.4.1.4756.20.440.20.1.64 | ColumneddPort3PacketsRxLocal | read-only | current | EDD Series card port3 traffic overview:: Packets Rx |
| 1.3.6.1.4.1.4756.20.440.20.1.65 | ColumneddPort3PacketsTxLocal | read-only | current | EDD Series card port3 traffic overview:: Packets Tx |
| 1.3.6.1.4.1.4756.20.440.20.1.66 | ColumneddPort3BytesRxLocal | read-only | current | EDD Series card port3 traffic overview:: Bytes Rx |
| 1.3.6.1.4.1.4756.20.440.20.1.67 | ColumneddPort3BytesTxLocal | read-only | current | EDD Series card port3 traffic overview:: Bytes Tx |
| 1.3.6.1.4.1.4756.20.440.20.1.68 | ColumneddPort3ErrorsRxLocal | read-only | current | EDD Series card port3 traffic overview:: Errors Rx |
| 1.3.6.1.4.1.4756.20.440.20.1.69 | ColumneddPort3ErrorsTxLocal | read-only | current | EDD Series card port3 traffic overview:: Errors Tx |
| 1.3.6.1.4.1.4756.20.440.20.1.70 | ColumneddPort3DropsRxLocal | read-only | current | EDD Series card port3 traffic overview:: Drops Rx |
| 1.3.6.1.4.1.4756.20.440.20.1.71 | ColumneddPort3DropsTxLocal | read-only | current | EDD Series card port3 traffic overview:: Drops Tx |
| 1.3.6.1.4.1.4756.20.440.20.1.72 | ColumneddPort3FilteredRxLocal | read-only | current | EDD Series card port3 traffic overview:: Filtered Rx |
| 1.3.6.1.4.1.4756.20.440.20.1.73 | ColumneddPort4PacketsRxLocal | read-only | current | EDD Series card port4 traffic overview:: Packets Rx |
| 1.3.6.1.4.1.4756.20.440.20.1.74 | ColumneddPort4PacketsTxLocal | read-only | current | EDD Series card port4 traffic overview:: Packets Tx |
| 1.3.6.1.4.1.4756.20.440.20.1.75 | ColumneddPort4BytesRxLocal | read-only | current | EDD Series card port4 traffic overview:: Bytes Rx |
| 1.3.6.1.4.1.4756.20.440.20.1.76 | ColumneddPort4BytesTxLocal | read-only | current | EDD Series card port4 traffic overview:: Bytes Tx |
| 1.3.6.1.4.1.4756.20.440.20.1.77 | ColumneddPort4ErrorsRxLocal | read-only | current | EDD Series card port4 traffic overview:: Errors Rx |
| 1.3.6.1.4.1.4756.20.440.20.1.78 | ColumneddPort4ErrorsTxLocal | read-only | current | EDD Series card port4 traffic overview:: Errors Tx |
| 1.3.6.1.4.1.4756.20.440.20.1.79 | ColumneddPort4DropsRxLocal | read-only | current | EDD Series card port4 traffic overview:: Drops Rx |
| 1.3.6.1.4.1.4756.20.440.20.1.80 | ColumneddPort4DropsTxLocal | read-only | current | EDD Series card port4 traffic overview:: Drops Tx |
| 1.3.6.1.4.1.4756.20.440.20.1.81 | ColumneddPort4FilteredRxLocal | read-only | current | EDD Series card port4 traffic overview:: Filtered Rx |
| 1.3.6.1.4.1.4756.20.440.20.1.82 | ColumnedduRingInstanceAddLocal | read-write | current | EDD Series card Add a new uRing Instance. Syntax: <Instance ID> <ring|sub|chain> <port east> <port west> Instance ID must be either 1 or 2 port east , the valu… |
| 1.3.6.1.4.1.4756.20.440.20.1.83 | ColumnedduRingInstanceDeleteLocal | read-write | current | EDD Series card Delete a uRing Instance. Syntax: <uRing Instance> |
| 1.3.6.1.4.1.4756.20.440.20.1.84 | ColumnedduRingInst1IDLocal | read-only | current | EDD Series card u-Ring instance1 ID |
| 1.3.6.1.4.1.4756.20.440.20.1.85 | ColumnedduRingInst1typeLocal | read-only | current | EDD Series card u-Ring instance1 type 0: u-Ring 1: Sub-Ring 2: u-Chain |
| 1.3.6.1.4.1.4756.20.440.20.1.86 | ColumnedduRingInst1masterLocal | read-write | current | EDD Series card u-Ring instance1 master 0: No 1: Yes |
| 1.3.6.1.4.1.4756.20.440.20.1.87 | ColumnedduRingInst1EastPortLocal | read-only | current | EDD Series card u-Ring instance1 east port |
| 1.3.6.1.4.1.4756.20.440.20.1.88 | ColumnedduRingInst1EastEdgeLocal | read-write | current | EDD Series card u-Ring instance1 east edge 0: No 1: Yes |
| 1.3.6.1.4.1.4756.20.440.20.1.89 | ColumnedduRingInst1WestPortLocal | read-only | current | EDD Series card u-Ring instance1 west port |
| 1.3.6.1.4.1.4756.20.440.20.1.90 | ColumnedduRingInst1WestEdgeLocal | read-write | current | EDD Series card u-Ring instance1 west edge 0: No 1: Yes |
| 1.3.6.1.4.1.4756.20.440.20.1.91 | ColumnedduRingInst2IDLocal | read-only | current | EDD Series card u-Ring instance2 ID |
| 1.3.6.1.4.1.4756.20.440.20.1.92 | ColumnedduRingInst2typeLocal | read-only | current | EDD Series card u-Ring instance2 type 0: u-Ring 1: Sub-Ring 2: u-Chain |
| 1.3.6.1.4.1.4756.20.440.20.1.93 | ColumnedduRingInst2masterLocal | read-write | current | EDD Series card u-Ring instance2 master 0: No 1: Yes |
| 1.3.6.1.4.1.4756.20.440.20.1.94 | ColumnedduRingInst2EastPortLocal | read-only | current | EDD Series card u-Ring instance2 east port |
| 1.3.6.1.4.1.4756.20.440.20.1.95 | ColumnedduRingInst2EastEdgeLocal | read-write | current | EDD Series card u-Ring instance2 east edge 0: No 1: Yes |
| 1.3.6.1.4.1.4756.20.440.20.1.96 | ColumnedduRingInst2WestPortLocal | read-only | current | EDD Series card u-Ring instance2 west port |
| 1.3.6.1.4.1.4756.20.440.20.1.97 | ColumnedduRingInst2WestEdgeLocal | read-write | current | EDD Series card u-Ring instance2 west edge 0: No 1: Yes |
| 1.3.6.1.4.1.4756.20.440.20.1.98 | ColumnedduRingInst1IDstsLocal | read-only | current | EDD Series card u-Ring Instance1 ID status |
| 1.3.6.1.4.1.4756.20.440.20.1.99 | ColumnedduRingInst1typestsLocal | read-only | current | EDD Series card u-Ring Type status |
| 1.3.6.1.4.1.4756.20.440.20.1.100 | ColumnedduRingInst1rolestsLocal | read-only | current | EDD Series card u-Ring Role status |
| 1.3.6.1.4.1.4756.20.440.20.1.101 | ColumnedduRingInst1EastPortstsLocal | read-only | current | EDD Series card u-Ring East port status |
| 1.3.6.1.4.1.4756.20.440.20.1.102 | ColumnedduRingInst1EaststsLocal | read-only | current | EDD Series card u-Ring East status |
| 1.3.6.1.4.1.4756.20.440.20.1.103 | ColumnedduRingInst1EastEdgestsLocal | read-only | current | EDD Series card u-Ring East edge status |
| 1.3.6.1.4.1.4756.20.440.20.1.104 | ColumnedduRingInst1WestPortstsLocal | read-only | current | EDD Series card u-Ring West edge status |
| 1.3.6.1.4.1.4756.20.440.20.1.105 | ColumnedduRingInst1WeststsLocal | read-only | current | EDD Series card u-Ring West status |
| 1.3.6.1.4.1.4756.20.440.20.1.106 | ColumnedduRingInst1WestEdgestsLocal | read-only | current | EDD Series card u-Ring West status |
| 1.3.6.1.4.1.4756.20.440.20.1.107 | ColumnedduRingInst1healthystsLocal | read-only | current | EDD Series card u-Ring healthy status None Fine Fault |
| 1.3.6.1.4.1.4756.20.440.20.1.108 | ColumnedduRingInst2IDstsLocal | read-only | current | EDD Series card u-Ring Instance2 ID status |
| 1.3.6.1.4.1.4756.20.440.20.1.109 | ColumnedduRingInst2typestsLocal | read-only | current | EDD Series card u-Ring Type status |
| 1.3.6.1.4.1.4756.20.440.20.1.110 | ColumnedduRingInst2rolestsLocal | read-only | current | EDD Series card u-Ring Role status |
| 1.3.6.1.4.1.4756.20.440.20.1.111 | ColumnedduRingInst2EastPortstsLocal | read-only | current | EDD Series card u-Ring East port status |
| 1.3.6.1.4.1.4756.20.440.20.1.112 | ColumnedduRingInst2EaststsLocal | read-only | current | EDD Series card u-Ring East status |
| 1.3.6.1.4.1.4756.20.440.20.1.113 | ColumnedduRingInst2EastEdgestsLocal | read-only | current | EDD Series card u-Ring East edge status |
| 1.3.6.1.4.1.4756.20.440.20.1.114 | ColumnedduRingInst2WestPortstsLocal | read-only | current | EDD Series card u-Ring West edge status |
| 1.3.6.1.4.1.4756.20.440.20.1.115 | ColumnedduRingInst2WeststsLocal | read-only | current | EDD Series card u-Ring West status |
| 1.3.6.1.4.1.4756.20.440.20.1.116 | ColumnedduRingInst2WestEdgestsLocal | read-only | current | EDD Series card u-Ring West status |
| 1.3.6.1.4.1.4756.20.440.20.1.117 | ColumnedduRingInst2healthystsLocal | read-only | current | EDD Series card u-Ring healthy status None Fine Fault |
| 1.3.6.1.4.1.4756.20.440.20.1.118 | ColumneddDeviceActiveLocal | read-write | current | EDD Series card u-Ring device active 0: Disable 1: Enable |
| 1.3.6.1.4.1.4756.20.440.20.1.119 | ColumneddFx1DDLocal | read-only | current | EDD Series card fiber port Digital Diagnostic function: 0:No 1:Yes |
| 1.3.6.1.4.1.4756.20.440.20.1.120 | ColumneddFx1DDVendorLocal | read-only | current | EDD Series card fiber port D/D information: Vendor name |
| 1.3.6.1.4.1.4756.20.440.20.1.121 | ColumneddFx1DDPartNoLocal | read-only | current | EDD Series card fiber port D/D information: Vendor part number |
| 1.3.6.1.4.1.4756.20.440.20.1.122 | ColumneddFx1DDFiberTypeLocal | read-only | current | EDD Series card fiber port D/D information: Fiber Type |
| 1.3.6.1.4.1.4756.20.440.20.1.123 | ColumneddFx1DDWaveLenLocal | read-only | current | EDD Series card fiber port D/D information: Wave length |
| 1.3.6.1.4.1.4756.20.440.20.1.124 | ColumneddFx1DDWaveLen2Local | read-only | current | EDD Series card fiber port D/D information: Wave length 2 |
| 1.3.6.1.4.1.4756.20.440.20.1.125 | ColumneddFx1DDLinkLenLocal | read-only | current | EDD Series card fiber port D/D information: Link length |
| 1.3.6.1.4.1.4756.20.440.20.1.126 | ColumneddFx1DDLenUnitLocal | read-only | current | EDD Series card fiber port D/D information: Length Unit |
| 1.3.6.1.4.1.4756.20.440.20.1.127 | ColumneddFx1DDStatusLocal | read-only | current | EDD Series card fiber port D/D information: Status Support |
| 1.3.6.1.4.1.4756.20.440.20.1.128 | ColumneddFx1DDRxSensLocal | read-only | current | EDD Series card fiber port D/D information: Rx Sensitivity |
| 1.3.6.1.4.1.4756.20.440.20.1.129 | ColumneddFx1DDTxPWRLocal | read-only | current | EDD Series card fiber port D/D information: Tx power |
| 1.3.6.1.4.1.4756.20.440.20.1.130 | ColumneddFx1DDRxPWRLocal | read-only | current | EDD Series card fiber port D/D information: Rx power |
| 1.3.6.1.4.1.4756.20.440.20.1.131 | ColumneddFx1DDTempLocal | read-only | current | EDD Series card fiber port D/D information: Temperature in degree C |
| 1.3.6.1.4.1.4756.20.440.20.1.132 | ColumneddFx1DDPWRMarginLocal | read-only | current | EDD Series card fiber port D/D information: Power margin |
| 1.3.6.1.4.1.4756.20.440.20.1.133 | ColumneddFx1DDPWRLossLocal | read-only | current | EDD Series card fiber port D/D information: Power loss |
| 1.3.6.1.4.1.4756.20.440.20.1.134 | ColumneddFx2DDLocal | read-only | current | EDD Series card fiber2 Digital Diagnostic function: 0:NO 1:Yes |
| 1.3.6.1.4.1.4756.20.440.20.1.135 | ColumneddFx2DDVendorLocal | read-only | current | EDD Series card fiber2 D/D information: Vendor name |
| 1.3.6.1.4.1.4756.20.440.20.1.136 | ColumneddFx2DDPartNoLocal | read-only | current | EDD Series card fiber2 D/D information: Vendor part number |
| 1.3.6.1.4.1.4756.20.440.20.1.137 | ColumneddFx2DDFiberTypeLocal | read-only | current | EDD Series card fiber2 D/D information: Fiber Type |
| 1.3.6.1.4.1.4756.20.440.20.1.138 | ColumneddFx2DDWaveLenLocal | read-only | current | EDD Series card fiber2 D/D information: Wave length 1 |
| 1.3.6.1.4.1.4756.20.440.20.1.139 | ColumneddFx2DDWaveLen2Local | read-only | current | EDD Series card fiber2 D/D information: Wave length 2 |
| 1.3.6.1.4.1.4756.20.440.20.1.140 | ColumneddFx2DDLinkLenLocal | read-only | current | EDD Series card fiber2 D/D information: Link length |
| 1.3.6.1.4.1.4756.20.440.20.1.141 | ColumneddFx2DDLenUnitLocal | read-only | current | EDD Series card fiber2 D/D information: Length Unit |
| 1.3.6.1.4.1.4756.20.440.20.1.142 | ColumneddFx2DDStatusLocal | read-only | current | EDD Series card fiber2 D/D information: Status Support |
| 1.3.6.1.4.1.4756.20.440.20.1.143 | ColumneddFx2DDRxSensLocal | read-only | current | EDD Series card fiber2 D/D information: Rx Sensitivity |
| 1.3.6.1.4.1.4756.20.440.20.1.144 | ColumneddFx2DDTxPWRLocal | read-only | current | EDD Series card fiber2 D/D information: Tx power |
| 1.3.6.1.4.1.4756.20.440.20.1.145 | ColumneddFx2DDRxPWRLocal | read-only | current | EDD Series card fiber2 D/D information: Rx power |
| 1.3.6.1.4.1.4756.20.440.20.1.146 | ColumneddFx2DDTempLocal | read-only | current | EDD Series card fiber2 D/D information: Temperature in degree C |
| 1.3.6.1.4.1.4756.20.440.20.1.147 | ColumneddFx2DDPWRMarginLocal | read-only | current | EDD Series card fiber2 D/D information: Power margin |
| 1.3.6.1.4.1.4756.20.440.20.1.148 | ColumneddFx2DDPWRLossLocal | read-only | current | EDD Series card fiber2 D/D information: Power loss |
| 1.3.6.1.4.1.4756.20.440.20.1.149 | ColumneddFx3DDLocal | read-only | current | EDD Series card fiber3 Digital Diagnostic function: 0:NO 1:Yes |
| 1.3.6.1.4.1.4756.20.440.20.1.150 | ColumneddFx3DDVendorLocal | read-only | current | EDD Series card fiber3 D/D information: Vendor name |
| 1.3.6.1.4.1.4756.20.440.20.1.151 | ColumneddFx3DDPartNoLocal | read-only | current | EDD Series card fiber32 D/D information: Vendor part number |
| 1.3.6.1.4.1.4756.20.440.20.1.152 | ColumneddFx3DDFiberTypeLocal | read-only | current | EDD Series card fiber3 D/D information: Fiber Type |
| 1.3.6.1.4.1.4756.20.440.20.1.153 | ColumneddFx3DDWaveLenLocal | read-only | current | EDD Series card fiber3 D/D information: Wave length 1 |
| 1.3.6.1.4.1.4756.20.440.20.1.154 | ColumneddFx3DDWaveLen2Local | read-only | current | EDD Series card fiber3 D/D information: Wave length 2 |
| 1.3.6.1.4.1.4756.20.440.20.1.155 | ColumneddFx3DDLinkLenLocal | read-only | current | EDD Series card fiber3 D/D information: Link length |
| 1.3.6.1.4.1.4756.20.440.20.1.156 | ColumneddFx3DDLenUnitLocal | read-only | current | EDD Series card fiber3 D/D information: Length Unit |
| 1.3.6.1.4.1.4756.20.440.20.1.157 | ColumneddFx3DDStatusLocal | read-only | current | EDD Series card fiber3 D/D information: Status Support |
| 1.3.6.1.4.1.4756.20.440.20.1.158 | ColumneddFx3DDRxSensLocal | read-only | current | EDD Series card fiber3 D/D information: Rx Sensitivity |
| 1.3.6.1.4.1.4756.20.440.20.1.159 | ColumneddFx3DDTxPWRLocal | read-only | current | EDD Series card fiber3 D/D information: Tx power |
| 1.3.6.1.4.1.4756.20.440.20.1.160 | ColumneddFx3DDRxPWRLocal | read-only | current | EDD Series card fiber3 D/D information: Rx power |
| 1.3.6.1.4.1.4756.20.440.20.1.161 | ColumneddFx3DDTempLocal | read-only | current | EDD Series card fiber3 D/D information: Temperature in degree C |
| 1.3.6.1.4.1.4756.20.440.20.1.162 | ColumneddFx3DDPWRMarginLocal | read-only | current | EDD Series card fiber3 D/D information: Power margin |
| 1.3.6.1.4.1.4756.20.440.20.1.163 | ColumneddFx3DDPWRLossLocal | read-only | current | EDD Series card fiber3 D/D information: Power loss |
| 1.3.6.1.4.1.4756.20.440.20.1.164 | ColumneddTestLocal | read-only | current | EDD Series card test led sts: 0: Off 1: On |
| 1.3.6.1.4.1.4756.20.440.20.1.165 | ColumneddClearPortCounterLocal | read-write | current | EDD Series card clear port counter: 0: Off 1: Action |
| 1.3.6.1.4.1.4756.20.440.20.1.166 | ColumneddAggrSourceMACAddrLocal | read-write | current | EDD Series card Aggregation Mode Configuration: Source MAC Address 0: No 1: Yes |
| 1.3.6.1.4.1.4756.20.440.20.1.167 | ColumneddAggrDestinationMACAddrLocal | read-write | current | EDD Series card Aggregation Mode Configuration: Destination MAC Address 0: No 1: Yes |
| 1.3.6.1.4.1.4756.20.440.20.1.168 | ColumneddAggrIPAddrLocal | read-write | current | EDD Series card Aggregation Mode Configuration: IP Address 0: No 1: Yes |
| 1.3.6.1.4.1.4756.20.440.20.1.169 | ColumneddAggrTCPUDPPortNumLocal | read-write | current | EDD Series card Aggregation Mode Configuration: TCP/UDP Port Number 0: No 1: Yes |
| 1.3.6.1.4.1.4756.20.440.20.1.170 | ColumneddAggrGroupPort1ConfLocal | read-write | current | EDD Series card Aggregation Group Port1 Configuration: 0: Normal 1: ID1 2: ID2 |
| 1.3.6.1.4.1.4756.20.440.20.1.171 | ColumneddAggrGroupPort2ConfLocal | read-write | current | EDD Series card Aggregation Group Port2 Configuration: 0: Normal 1: ID1 2: ID2 |
| 1.3.6.1.4.1.4756.20.440.20.1.172 | ColumneddAggrGroupPort3ConfLocal | read-write | current | EDD Series card Aggregation Group Port3 Configuration: 0: Normal 1: ID1 2: ID2 |
| 1.3.6.1.4.1.4756.20.440.20.1.173 | ColumneddAggrGroupPort4ConfLocal | read-write | current | EDD Series card Aggregation Group Port4 Configuration: 0: Normal 1: ID1 2: ID2 |
| 1.3.6.1.4.1.4756.20.440.20.1.174 | ColumneddPort1LACPEnabledLocal | read-write | current | EDD Series card Port1 LACP Enabled: 0: No 1: Yes |
| 1.3.6.1.4.1.4756.20.440.20.1.175 | ColumneddPort1LACPKEYLocal | read-write | current | EDD Series card Port1 LACP Key value: The Key value incurred by the port, range 0-65535.The value of 0 means auto. |
| 1.3.6.1.4.1.4756.20.440.20.1.176 | ColumneddPort1LACPRoleLocal | read-write | current | EDD Series card Port1 LACP Role: 0: Passive 1: Active |
| 1.3.6.1.4.1.4756.20.440.20.1.177 | ColumneddPort1LACPTimeOutLocal | read-write | current | EDD Series card Port1 LACP Time out: 0: Slow 1: Fast |
| 1.3.6.1.4.1.4756.20.440.20.1.178 | ColumneddPort1LACPPrioLocal | read-write | current | EDD Series card Port1 LACP priority: The Key value incurred by the port, range 1-65535. |
| 1.3.6.1.4.1.4756.20.440.20.1.179 | ColumneddPort2LACPEnabledLocal | read-write | current | EDD Series card Port2 LACP Enabled: 0: No 1: Yes |
| 1.3.6.1.4.1.4756.20.440.20.1.180 | ColumneddPort2LACPKEYLocal | read-write | current | EDD Series card Port2 LACP Key value: The Key value incurred by the port, range 0-65535.The value of 0 means auto. |
| 1.3.6.1.4.1.4756.20.440.20.1.181 | ColumneddPort2LACPRoleLocal | read-write | current | EDD Series card Port2 LACP Role: 0: Passive 1: Active |
| 1.3.6.1.4.1.4756.20.440.20.1.182 | ColumneddPort2LACPTimeOutLocal | read-write | current | EDD Series card Port2 LACP Time out: 0: Slow 1: Fast |
| 1.3.6.1.4.1.4756.20.440.20.1.183 | ColumneddPort2LACPPrioLocal | read-write | current | EDD Series card Port2 LACP priority: The Key value incurred by the port, range 1-65535. |
| 1.3.6.1.4.1.4756.20.440.20.1.184 | ColumneddPort3LACPEnabledLocal | read-write | current | EDD Series card Port3 LACP Enabled: 0: No 1: Yes |
| 1.3.6.1.4.1.4756.20.440.20.1.185 | ColumneddPort3LACPKEYLocal | read-write | current | EDD Series card Port3 LACP Key value: The Key value incurred by the port, range 0-65535.The value of 0 means auto. |
| 1.3.6.1.4.1.4756.20.440.20.1.186 | ColumneddPort3LACPRoleLocal | read-write | current | EDD Series card Port3 LACP Role: 0: Passive 1: Active |
| 1.3.6.1.4.1.4756.20.440.20.1.187 | ColumneddPort3LACPTimeOutLocal | read-write | current | EDD Series card Port3 LACP Time out: 0: Slow 1: Fast |
| 1.3.6.1.4.1.4756.20.440.20.1.188 | ColumneddPort3LACPPrioLocal | read-write | current | EDD Series card Port3 LACP priority: The Key value incurred by the port, range 1-65535. |
| 1.3.6.1.4.1.4756.20.440.20.1.189 | ColumneddPort4LACPEnabledLocal | read-write | current | EDD Series card Port4 LACP Enabled: 0: No 1: Yes |
| 1.3.6.1.4.1.4756.20.440.20.1.190 | ColumneddPort4LACPKEYLocal | read-write | current | EDD Series card Port4 LACP Key value: The Key value incurred by the port, range 0-65535.The value of 0 means auto. |
| 1.3.6.1.4.1.4756.20.440.20.1.191 | ColumneddPort4LACPRoleLocal | read-write | current | EDD Series card Port4 LACP Role: 0: Passive 1: Active |
| 1.3.6.1.4.1.4756.20.440.20.1.192 | ColumneddPort4LACPTimeOutLocal | read-write | current | EDD Series card Port4 LACP Time out: 0: Slow 1: Fast |
| 1.3.6.1.4.1.4756.20.440.20.1.193 | ColumneddPort4LACPPrioLocal | read-write | current | EDD Series card Port4 LACP priority: The Key value incurred by the port, range 1-65535. |
| 1.3.6.1.4.1.4756.20.440.20.1.194 | ColumneddPort1LACPstsLocal | read-only | current | EDD Series card Port1 LACP status: 0: No 1: Yes 2: Standby |
| 1.3.6.1.4.1.4756.20.440.20.1.195 | ColumneddPort1LACPKEYstsLocal | read-only | current | EDD Series card Port1 LACP status: Key |
| 1.3.6.1.4.1.4756.20.440.20.1.196 | ColumneddPort1LACPAggrIDstsLocal | read-only | current | EDD Series card Port1 LACP status: Aggr ID |
| 1.3.6.1.4.1.4756.20.440.20.1.197 | ColumneddPort1LACPParnterSysIDstsLocal | read-only | current | EDD Series card Port1 LACP status: Parnter System ID |
| 1.3.6.1.4.1.4756.20.440.20.1.198 | ColumneddPort1LACPParnterPortstsLocal | read-only | current | EDD Series card Port1 LACP status: Parnter Port Status |
| 1.3.6.1.4.1.4756.20.440.20.1.199 | ColumneddPort1LACPParnterProistsLocal | read-only | current | EDD Series card Port1 LACP status: Parnter Priority |
| 1.3.6.1.4.1.4756.20.440.20.1.200 | ColumneddPort2LACPstsLocal | read-only | current | EDD Series card Port2 LACP status: 0: No 1: Yes 2: Standby |
| 1.3.6.1.4.1.4756.20.440.20.1.201 | ColumneddPort2LACPKEYstsLocal | read-only | current | EDD Series card Port2 LACP status: Key |
| 1.3.6.1.4.1.4756.20.440.20.1.202 | ColumneddPort2LACPAggrIDstsLocal | read-only | current | EDD Series card Port2 LACP status: Aggr ID |
| 1.3.6.1.4.1.4756.20.440.20.1.203 | ColumneddPort2LACPParnterSysIDstsLocal | read-only | current | EDD Series card Port2 LACP status: Parnter System ID |
| 1.3.6.1.4.1.4756.20.440.20.1.204 | ColumneddPort2LACPParnterPortstsLocal | read-only | current | EDD Series card Port2 LACP status: Parnter Port Status |
| 1.3.6.1.4.1.4756.20.440.20.1.205 | ColumneddPort2LACPParnterProistsLocal | read-only | current | EDD Series card Port2 LACP status: Parnter Priority |
| 1.3.6.1.4.1.4756.20.440.20.1.206 | ColumneddPort3LACPstsLocal | read-only | current | EDD Series card Port3 LACP status: 0: No 1: Yes 2: Standby |
| 1.3.6.1.4.1.4756.20.440.20.1.207 | ColumneddPort3LACPKEYstsLocal | read-only | current | EDD Series card Port3 LACP status: Key |
| 1.3.6.1.4.1.4756.20.440.20.1.208 | ColumneddPort3LACPAggrIDstsLocal | read-only | current | EDD Series card Port3 LACP status: Aggr ID |
| 1.3.6.1.4.1.4756.20.440.20.1.209 | ColumneddPort3LACPParnterSysIDstsLocal | read-only | current | EDD Series card Port3 LACP status: Parnter System ID |
| 1.3.6.1.4.1.4756.20.440.20.1.210 | ColumneddPort3LACPParnterPortstsLocal | read-only | current | EDD Series card Port3 LACP status: Parnter Port Status |
| 1.3.6.1.4.1.4756.20.440.20.1.211 | ColumneddPort3LACPParnterProistsLocal | read-only | current | EDD Series card Port3 LACP status: Parnter Priority |
| 1.3.6.1.4.1.4756.20.440.20.1.212 | ColumneddPort4LACPstsLocal | read-only | current | EDD Series card Port4 LACP status: 0: No 1: Yes 2: Standby |
| 1.3.6.1.4.1.4756.20.440.20.1.213 | ColumneddPort4LACPKEYstsLocal | read-only | current | EDD Series card Port4 LACP status: Key |
| 1.3.6.1.4.1.4756.20.440.20.1.214 | ColumneddPort4LACPAggrIDstsLocal | read-only | current | EDD Series card Port4 LACP status: Aggr ID |
| 1.3.6.1.4.1.4756.20.440.20.1.215 | ColumneddPort4LACPParnterSysIDstsLocal | read-only | current | EDD Series card Port4 LACP status: Parnter System ID |
| 1.3.6.1.4.1.4756.20.440.20.1.216 | ColumneddPort4LACPParnterPortstsLocal | read-only | current | EDD Series card Port4 LACP status: Parnter Port Status |
| 1.3.6.1.4.1.4756.20.440.20.1.217 | ColumneddPort4LACPParnterProistsLocal | read-only | current | EDD Series card Port4 LACP status: Parnter Priority |
| 1.3.6.1.4.1.4756.20.440.20.1.218 | ColumneddOAMPort1EnableLocal | read-write | current | EDD Series card Port1 OAM: 0: Off 1: On |
| 1.3.6.1.4.1.4756.20.440.20.1.219 | ColumneddOAMPort1ModeLocal | read-write | current | EDD Series card Port1 OAM: 0: Passive 1: Active |
| 1.3.6.1.4.1.4756.20.440.20.1.220 | ColumneddOAMPort1LoopBackLocal | read-write | current | EDD Series card Port1 OAM LoopBack: 0: Off 1: On |
| 1.3.6.1.4.1.4756.20.440.20.1.221 | ColumneddOAMPort1LinkMonitorLocal | read-write | current | EDD Series card Port1 OAM Link Monitor: 0: Off 1: On |
| 1.3.6.1.4.1.4756.20.440.20.1.222 | ColumneddOAMPort1MIBRetrievalLocal | read-write | current | EDD Series card Port1 OAM MIB Retrieval: 0: Off 1: On |
| 1.3.6.1.4.1.4756.20.440.20.1.223 | ColumneddOAMPort1LoopBackOPLocal | read-write | current | EDD Series card Port1 OAM LoopBack operation: 0: Off 1: On |
| 1.3.6.1.4.1.4756.20.440.20.1.224 | ColumneddOAMPort2EnableLocal | read-write | current | EDD Series card Port2 OAM: 0: Off 1: On |
| 1.3.6.1.4.1.4756.20.440.20.1.225 | ColumneddOAMPort2ModeLocal | read-write | current | EDD Series card Port2 OAM: 0: Passive 1: Active |
| 1.3.6.1.4.1.4756.20.440.20.1.226 | ColumneddOAMPort2LoopBackLocal | read-write | current | EDD Series card Port2 OAM LoopBack: 0: Off 1: On |
| 1.3.6.1.4.1.4756.20.440.20.1.227 | ColumneddOAMPort2LinkMonitorLocal | read-write | current | EDD Series card Port2 OAM Link Monitor: 0: Off 1: On |
| 1.3.6.1.4.1.4756.20.440.20.1.228 | ColumneddOAMPort2MIBRetrievalLocal | read-write | current | EDD Series card Port2 OAM MIB Retrieval: 0: Off 1: On |
| 1.3.6.1.4.1.4756.20.440.20.1.229 | ColumneddOAMPort2LoopBackOPLocal | read-write | current | EDD Series card Port2 OAM LoopBack operation: 0: Off 1: On |
| 1.3.6.1.4.1.4756.20.440.20.1.230 | ColumneddOAMPort3EnableLocal | read-write | current | EDD Series card Port3 OAM: 0: Off 1: On |
| 1.3.6.1.4.1.4756.20.440.20.1.231 | ColumneddOAMPort3ModeLocal | read-write | current | EDD Series card Port3 OAM: 0: Passive 1: Active |
| 1.3.6.1.4.1.4756.20.440.20.1.232 | ColumneddOAMPort3LoopBackLocal | read-write | current | EDD Series card Port3 OAM: 0: Off 1: On |
| 1.3.6.1.4.1.4756.20.440.20.1.233 | ColumneddOAMPort3LinkMonitorLocal | read-write | current | EDD Series card Port3 OAM Link Monitor: 0: Off 1: On |
| 1.3.6.1.4.1.4756.20.440.20.1.234 | ColumneddOAMPort3MIBRetrievalLocal | read-write | current | EDD Series card Port3 OAM MIB Retrieval: 0: Off 1: On |
| 1.3.6.1.4.1.4756.20.440.20.1.235 | ColumneddOAMPort3LoopBackOPLocal | read-write | current | EDD Series card Port3 OAM LoopBack operation: 0: Disable 1: Enable |
| 1.3.6.1.4.1.4756.20.440.20.1.236 | ColumneddOAMPort4EnableLocal | read-write | current | EDD Series card Port4 OAM: 0: Off 1: On |
| 1.3.6.1.4.1.4756.20.440.20.1.237 | ColumneddOAMPort4ModeLocal | read-write | current | EDD Series card Port4 OAM: 0: Passive 1: Active |
| 1.3.6.1.4.1.4756.20.440.20.1.238 | ColumneddOAMPort4LoopBackLocal | read-write | current | EDD Series card Port4 OAM: 0: Off 1: On |
| 1.3.6.1.4.1.4756.20.440.20.1.239 | ColumneddOAMPort4LinkMonitorLocal | read-write | current | EDD Series card Port4 OAM Link Monitor: 0: Off 1: On |
| 1.3.6.1.4.1.4756.20.440.20.1.240 | ColumneddOAMPort4MIBRetrievalLocal | read-write | current | EDD Series card Port4 OAM MIB Retrieval: 0: Off 1: On |
| 1.3.6.1.4.1.4756.20.440.20.1.241 | ColumneddOAMPort4LoopBackOPLocal | read-write | current | EDD Series card Port4 OAM LoopBack operation: 0: On 1: Off |
| 1.3.6.1.4.1.4756.20.440.20.1.242 | ColumneddPort1EFEErrorWindowLocal | read-write | current | EDD Series card Port1 Link Event Configuration: Error Frame Event - Error Window |
| 1.3.6.1.4.1.4756.20.440.20.1.243 | ColumneddPort1EFEErrorThresholdLocal | read-write | current | EDD Series card Port1 Link Event Configuration: Error Frame Event - Error Threshold |
| 1.3.6.1.4.1.4756.20.440.20.1.244 | ColumneddPort1SPEEErrorWindowLocal | read-write | current | EDD Series card Port1 Link Event Configuration: Symbol Period Error Event - Error Window |
| 1.3.6.1.4.1.4756.20.440.20.1.245 | ColumneddPort1SPEEErrorThresholdLocal | read-write | current | EDD Series card Port1 Link Event Configuration: Symbol Period Error Event - Error Threshold |
| 1.3.6.1.4.1.4756.20.440.20.1.246 | ColumneddPort1SSEErrorWindowLocal | read-write | current | EDD Series card Port1 Link Event Configuration: Seconds Summary Event - Error Window |
| 1.3.6.1.4.1.4756.20.440.20.1.247 | ColumneddPort1SSEErrorThresholdLocal | read-write | current | EDD Series card Port1 Link Event Configuration: Seconds Summary Event - Error Threshold |
| 1.3.6.1.4.1.4756.20.440.20.1.248 | ColumneddPort2EFEErrorWindowLocal | read-write | current | EDD Series card Port2 Link Event Configuration: Error Frame Event - Error Window |
| 1.3.6.1.4.1.4756.20.440.20.1.249 | ColumneddPort2EFEErrorThresholdLocal | read-write | current | EDD Series card Port2 Link Event Configuration: Error Frame Event - Error Threshold |
| 1.3.6.1.4.1.4756.20.440.20.1.250 | ColumneddPort2SPEEErrorWindowLocal | read-write | current | EDD Series card Port2 Link Event Configuration: Symbol Period Error Event - Error Window |
| 1.3.6.1.4.1.4756.20.440.20.1.251 | ColumneddPort2SPEEErrorThresholdLocal | read-write | current | EDD Series card Port2 Link Event Configuration: Symbol Period Error Event - Error Threshold |
| 1.3.6.1.4.1.4756.20.440.20.1.252 | ColumneddPort2SSEErrorWindowLocal | read-write | current | EDD Series card Port2 Link Event Configuration: Seconds Summary Event - Error Window |
| 1.3.6.1.4.1.4756.20.440.20.1.253 | ColumneddPort2SSEErrorThresholdLocal | read-write | current | EDD Series card Port2 Link Event Configuration: Seconds Summary Event - Error Threshold |
| 1.3.6.1.4.1.4756.20.440.20.1.254 | ColumneddPort3EFEErrorWindowLocal | read-write | current | EDD Series card Port3 Link Event Configuration: Error Frame Event - Error Window |
| 1.3.6.1.4.1.4756.20.440.20.1.255 | ColumneddPort3EFEErrorThresholdLocal | read-write | current | EDD Series card Port3 Link Event Configuration: Error Frame Event - Error Threshold |
| 1.3.6.1.4.1.4756.20.440.20.1.256 | ColumneddPort3SPEEErrorWindowLocal | read-write | current | EDD Series card Port3 Link Event Configuration: Symbol Period Error Event - Error Window |
| 1.3.6.1.4.1.4756.20.440.20.1.257 | ColumneddPort3SPEEErrorThresholdLocal | read-write | current | EDD Series card Port3 Link Event Configuration: Symbol Period Error Event - Error Threshold |
| 1.3.6.1.4.1.4756.20.440.20.1.258 | ColumneddPort3SSEErrorWindowLocal | read-write | current | EDD Series card Port3 Link Event Configuration: Seconds Summary Event - Error Window |
| 1.3.6.1.4.1.4756.20.440.20.1.259 | ColumneddPort3SSEErrorThresholdLocal | read-write | current | EDD Series card Port3 Link Event Configuration: Seconds Summary Event - Error Threshold |
| 1.3.6.1.4.1.4756.20.440.20.1.260 | ColumneddPort4EFEErrorWindowLocal | read-write | current | EDD Series card Port4 Link Event Configuration: Error Frame Event - Error Window |
| 1.3.6.1.4.1.4756.20.440.20.1.261 | ColumneddPort4EFEErrorThresholdLocal | read-write | current | EDD Series card Port4 Link Event Configuration: Error Frame Event - Error Threshold |
| 1.3.6.1.4.1.4756.20.440.20.1.262 | ColumneddPort4SPEEErrorWindowLocal | read-write | current | EDD Series card Port4 Link Event Configuration: Symbol Period Error Event - Error Window |
| 1.3.6.1.4.1.4756.20.440.20.1.263 | ColumneddPort4SPEEErrorThresholdLocal | read-write | current | EDD Series card Port4 Link Event Configuration: Symbol Period Error Event - Error Threshold |
| 1.3.6.1.4.1.4756.20.440.20.1.264 | ColumneddPort4SSEErrorWindowLocal | read-write | current | EDD Series card Port4 Link Event Configuration: Seconds Summary Event - Error Window |
| 1.3.6.1.4.1.4756.20.440.20.1.265 | ColumneddPort4SSEErrorThresholdLocal | read-write | current | EDD Series card Port4 Link Event Configuration: Seconds Summary Event - Error Threshold |
| 1.3.6.1.4.1.4756.20.440.20.1.266 | ColumneddPort1RxOAMInfoPDULocal | read-only | current | EDD Series card Port1 Detailed Link OAM Statistics: Rx OAM Information PDU's |
| 1.3.6.1.4.1.4756.20.440.20.1.267 | ColumneddPort1RxUniqueErrorEventLocal | read-only | current | EDD Series card Port1 Detailed Link OAM Statistics: Rx Unique Error Event Notificatio |
| 1.3.6.1.4.1.4756.20.440.20.1.268 | ColumneddPort1RxDuplicateErrorEventLocal | read-only | current | EDD Series card Port1 Detailed Link OAM Statistics: Rx Duplicate Error Event Notification |
| 1.3.6.1.4.1.4756.20.440.20.1.269 | ColumneddPort1RxLoopBackControlLocal | read-only | current | EDD Series card Port1 Detailed Link OAM Statistics: Rx Loopback Control |
| 1.3.6.1.4.1.4756.20.440.20.1.270 | ColumneddPort1RxVariableRequestLocal | read-only | current | EDD Series card Port1 Detailed Link OAM Statistics: Rx Variable Request |
| 1.3.6.1.4.1.4756.20.440.20.1.271 | ColumneddPort1RxVariableResponseLocal | read-only | current | EDD Series card Port1 Detailed Link OAM Statistics: Rx Variable Response |
| 1.3.6.1.4.1.4756.20.440.20.1.272 | ColumneddPort1RxOrgSpecificPDULocal | read-only | current | EDD Series card Port1 Detailed Link OAM Statistics: Rx Org Specific PDU's |
| 1.3.6.1.4.1.4756.20.440.20.1.273 | ColumneddPort1RxUnsupportedCodesLocal | read-only | current | EDD Series card Port1 Detailed Link OAM Statistics: Rx Unsupported Codes |
| 1.3.6.1.4.1.4756.20.440.20.1.274 | ColumneddPort1RxLinkFaultPDULocal | read-only | current | EDD Series card Port1 Detailed Link OAM Statistics: Rx Link Fault PDU's |
| 1.3.6.1.4.1.4756.20.440.20.1.275 | ColumneddPort1RxDyingGaspLocal | read-only | current | EDD Series card Port1 Detailed Link OAM Statistics: Rx Dying Gasp |
| 1.3.6.1.4.1.4756.20.440.20.1.276 | ColumneddPort1RxCriticalEventPDULocal | read-only | current | EDD Series card Port1 Detailed Link OAM Statistics: Rx Dying Gasp |
| 1.3.6.1.4.1.4756.20.440.20.1.277 | ColumneddPort1TxOAMInfoPDULocal | read-only | current | EDD Series card Port1 Detailed Link OAM Statistics: Tx OAM Information PDU's |
| 1.3.6.1.4.1.4756.20.440.20.1.278 | ColumneddPort1TxUniqueErrorEventLocal | read-only | current | EDD Series card Port1 Detailed Link OAM Statistics: Tx Unique Error Event Notificatio |
| 1.3.6.1.4.1.4756.20.440.20.1.279 | ColumneddPort1TxDuplicateErrorEventLocal | read-only | current | EDD Series card Port1 Detailed Link OAM Statistics: Tx Duplicate Error Event Notification |
| 1.3.6.1.4.1.4756.20.440.20.1.280 | ColumneddPort1TxLoopBackControlLocal | read-only | current | EDD Series card Port1 Detailed Link OAM Statistics: Tx Loopback Control |
| 1.3.6.1.4.1.4756.20.440.20.1.281 | ColumneddPort1TxVariableRequestLocal | read-only | current | EDD Series card Port1 Detailed Link OAM Statistics: Tx Variable Request |
| 1.3.6.1.4.1.4756.20.440.20.1.282 | ColumneddPort1TxVariableResponseLocal | read-only | current | EDD Series card Port1 Detailed Link OAM Statistics: Tx Variable Response |
| 1.3.6.1.4.1.4756.20.440.20.1.283 | ColumneddPort1TxOrgSpecificPDULocal | read-only | current | EDD Series card Port1 Detailed Link OAM Statistics: Tx Org Specific PDU's |
| 1.3.6.1.4.1.4756.20.440.20.1.284 | ColumneddPort1TxUnsupportedCodesLocal | read-only | current | EDD Series card Port1 Detailed Link OAM Statistics: Tx Unsupported Codes |
| 1.3.6.1.4.1.4756.20.440.20.1.285 | ColumneddPort1TxLinkFaultPDULocal | read-only | current | EDD Series card Port1 Detailed Link OAM Statistics: Tx Link Fault PDU's |
| 1.3.6.1.4.1.4756.20.440.20.1.286 | ColumneddPort1TxDyingGaspLocal | read-only | current | EDD Series card Port1 Detailed Link OAM Statistics: Tx Dying Gasp |
| 1.3.6.1.4.1.4756.20.440.20.1.287 | ColumneddPort1TxCriticalEventPDULocal | read-only | current | EDD Series card Port1 Detailed Link OAM Statistics: Tx Dying Gasp |
| 1.3.6.1.4.1.4756.20.440.20.1.288 | ColumneddPort2RxOAMInfoPDULocal | read-only | current | EDD Series card Port2 Detailed Link OAM Statistics: Rx OAM Information PDU's |
| 1.3.6.1.4.1.4756.20.440.20.1.289 | ColumneddPort2RxUniqueErrorEventLocal | read-only | current | EDD Series card Port2 Detailed Link OAM Statistics: Rx Unique Error Event Notificatio |
| 1.3.6.1.4.1.4756.20.440.20.1.290 | ColumneddPort2RxDuplicateErrorEventLocal | read-only | current | EDD Series card Port2 Detailed Link OAM Statistics: Rx Duplicate Error Event Notification |
| 1.3.6.1.4.1.4756.20.440.20.1.291 | ColumneddPort2RxLoopBackControlLocal | read-only | current | EDD Series card Port2 Detailed Link OAM Statistics: Rx Loopback Control |
| 1.3.6.1.4.1.4756.20.440.20.1.292 | ColumneddPort2RxVariableRequestLocal | read-only | current | EDD Series card Port2 Detailed Link OAM Statistics: Rx Variable Request |
| 1.3.6.1.4.1.4756.20.440.20.1.293 | ColumneddPort2RxVariableResponseLocal | read-only | current | EDD Series card Port2 Detailed Link OAM Statistics: Rx Variable Response |
| 1.3.6.1.4.1.4756.20.440.20.1.294 | ColumneddPort2RxOrgSpecificPDULocal | read-only | current | EDD Series card Port2 Detailed Link OAM Statistics: Rx Org Specific PDU's |
| 1.3.6.1.4.1.4756.20.440.20.1.295 | ColumneddPort2RxUnsupportedCodesLocal | read-only | current | EDD Series card Port2 Detailed Link OAM Statistics: Rx Unsupported Codes |
| 1.3.6.1.4.1.4756.20.440.20.1.296 | ColumneddPort2RxLinkFaultPDULocal | read-only | current | EDD Series card Port2 Detailed Link OAM Statistics: Rx Link Fault PDU's |
| 1.3.6.1.4.1.4756.20.440.20.1.297 | ColumneddPort2RxDyingGaspLocal | read-only | current | EDD Series card Port2 Detailed Link OAM Statistics: Rx Dying Gasp |
| 1.3.6.1.4.1.4756.20.440.20.1.298 | ColumneddPort2RxCriticalEventPDULocal | read-only | current | EDD Series card Port2 Detailed Link OAM Statistics: Rx Dying Gasp |
| 1.3.6.1.4.1.4756.20.440.20.1.299 | ColumneddPort2TxOAMInfoPDULocal | read-only | current | EDD Series card Port2 Detailed Link OAM Statistics: Tx OAM Information PDU's |
| 1.3.6.1.4.1.4756.20.440.20.1.300 | ColumneddPort2TxUniqueErrorEventLocal | read-only | current | EDD Series card Port2 Detailed Link OAM Statistics: Tx Unique Error Event Notificatio |
| 1.3.6.1.4.1.4756.20.440.20.1.301 | ColumneddPort2TxDuplicateErrorEventLocal | read-only | current | EDD Series card Port2 Detailed Link OAM Statistics: Tx Duplicate Error Event Notification |
| 1.3.6.1.4.1.4756.20.440.20.1.302 | ColumneddPort2TxLoopBackControlLocal | read-only | current | EDD Series card Port2 Detailed Link OAM Statistics: Tx Loopback Control |
| 1.3.6.1.4.1.4756.20.440.20.1.303 | ColumneddPort2TxVariableRequestLocal | read-only | current | EDD Series card Port2 Detailed Link OAM Statistics: Tx Variable Request |
| 1.3.6.1.4.1.4756.20.440.20.1.304 | ColumneddPort2TxVariableResponseLocal | read-only | current | EDD Series card Port2 Detailed Link OAM Statistics: Tx Variable Response |
| 1.3.6.1.4.1.4756.20.440.20.1.305 | ColumneddPort2TxOrgSpecificPDULocal | read-only | current | EDD Series card Port2 Detailed Link OAM Statistics: Tx Org Specific PDU's |
| 1.3.6.1.4.1.4756.20.440.20.1.306 | ColumneddPort2TxUnsupportedCodesLocal | read-only | current | EDD Series card Port2 Detailed Link OAM Statistics: Tx Unsupported Codes |
| 1.3.6.1.4.1.4756.20.440.20.1.307 | ColumneddPort2TxLinkFaultPDULocal | read-only | current | EDD Series card Port2 Detailed Link OAM Statistics: Tx Link Fault PDU's |
| 1.3.6.1.4.1.4756.20.440.20.1.308 | ColumneddPort2TxDyingGaspLocal | read-only | current | EDD Series card Port2 Detailed Link OAM Statistics: Tx Dying Gasp |
| 1.3.6.1.4.1.4756.20.440.20.1.309 | ColumneddPort2TxCriticalEventPDULocal | read-only | current | EDD Series card Port2 Detailed Link OAM Statistics: Tx Dying Gasp |
| 1.3.6.1.4.1.4756.20.440.20.1.310 | ColumneddPort3RxOAMInfoPDULocal | read-only | current | EDD Series card Port3 Detailed Link OAM Statistics: Rx OAM Information PDU's |
| 1.3.6.1.4.1.4756.20.440.20.1.311 | ColumneddPort3RxUniqueErrorEventLocal | read-only | current | EDD Series card Port3 Detailed Link OAM Statistics: Rx Unique Error Event Notificatio |
| 1.3.6.1.4.1.4756.20.440.20.1.312 | ColumneddPort3RxDuplicateErrorEventLocal | read-only | current | EDD Series card Port3 Detailed Link OAM Statistics: Rx Duplicate Error Event Notification |
| 1.3.6.1.4.1.4756.20.440.20.1.313 | ColumneddPort3RxLoopBackControlLocal | read-only | current | EDD Series card Port3 Detailed Link OAM Statistics: Rx Loopback Control |
| 1.3.6.1.4.1.4756.20.440.20.1.314 | ColumneddPort3RxVariableRequestLocal | read-only | current | EDD Series card Port3 Detailed Link OAM Statistics: Rx Variable Request |
| 1.3.6.1.4.1.4756.20.440.20.1.315 | ColumneddPort3RxVariableResponseLocal | read-only | current | EDD Series card Port3 Detailed Link OAM Statistics: Rx Variable Response |
| 1.3.6.1.4.1.4756.20.440.20.1.316 | ColumneddPort3RxOrgSpecificPDULocal | read-only | current | EDD Series card Port3 Detailed Link OAM Statistics: Rx Org Specific PDU's |
| 1.3.6.1.4.1.4756.20.440.20.1.317 | ColumneddPort3RxUnsupportedCodesLocal | read-only | current | EDD Series card Port3 Detailed Link OAM Statistics: Rx Unsupported Codes |
| 1.3.6.1.4.1.4756.20.440.20.1.318 | ColumneddPort3RxLinkFaultPDULocal | read-only | current | EDD Series card Port3 Detailed Link OAM Statistics: Rx Link Fault PDU's |
| 1.3.6.1.4.1.4756.20.440.20.1.319 | ColumneddPort3RxDyingGaspLocal | read-only | current | EDD Series card Port3 Detailed Link OAM Statistics: Rx Dying Gasp |
| 1.3.6.1.4.1.4756.20.440.20.1.320 | ColumneddPort3RxCriticalEventPDULocal | read-only | current | EDD Series card Port3 Detailed Link OAM Statistics: Rx Dying Gasp |
| 1.3.6.1.4.1.4756.20.440.20.1.321 | ColumneddPort3TxOAMInfoPDULocal | read-only | current | EDD Series card Port3 Detailed Link OAM Statistics: Tx OAM Information PDU's |
| 1.3.6.1.4.1.4756.20.440.20.1.322 | ColumneddPort3TxUniqueErrorEventLocal | read-only | current | EDD Series card Port3 Detailed Link OAM Statistics: Tx Unique Error Event Notificatio |
| 1.3.6.1.4.1.4756.20.440.20.1.323 | ColumneddPort3TxDuplicateErrorEventLocal | read-only | current | EDD Series card Port3 Detailed Link OAM Statistics: Tx Duplicate Error Event Notification |
| 1.3.6.1.4.1.4756.20.440.20.1.324 | ColumneddPort3TxLoopBackControlLocal | read-only | current | EDD Series card Port3 Detailed Link OAM Statistics: Tx Loopback Control |
| 1.3.6.1.4.1.4756.20.440.20.1.325 | ColumneddPort3TxVariableRequestLocal | read-only | current | EDD Series card Port3 Detailed Link OAM Statistics: Tx Variable Request |
| 1.3.6.1.4.1.4756.20.440.20.1.326 | ColumneddPort3TxVariableResponseLocal | read-only | current | EDD Series card Port3 Detailed Link OAM Statistics: Tx Variable Response |
| 1.3.6.1.4.1.4756.20.440.20.1.327 | ColumneddPort3TxOrgSpecificPDULocal | read-only | current | EDD Series card Port3 Detailed Link OAM Statistics: Tx Org Specific PDU's |
| 1.3.6.1.4.1.4756.20.440.20.1.328 | ColumneddPort3TxUnsupportedCodesLocal | read-only | current | EDD Series card Port3 Detailed Link OAM Statistics: Tx Unsupported Codes |
| 1.3.6.1.4.1.4756.20.440.20.1.329 | ColumneddPort3TxLinkFaultPDULocal | read-only | current | EDD Series card Port3 Detailed Link OAM Statistics: Tx Link Fault PDU's |
| 1.3.6.1.4.1.4756.20.440.20.1.330 | ColumneddPort3TxDyingGaspLocal | read-only | current | EDD Series card Port3 Detailed Link OAM Statistics: Tx Dying Gasp |
| 1.3.6.1.4.1.4756.20.440.20.1.331 | ColumneddPort3TxCriticalEventPDULocal | read-only | current | EDD Series card Port3 Detailed Link OAM Statistics: Tx Dying Gasp |
| 1.3.6.1.4.1.4756.20.440.20.1.332 | ColumneddPort4RxOAMInfoPDULocal | read-only | current | EDD Series card Port4 Detailed Link OAM Statistics: Rx OAM Information PDU's |
| 1.3.6.1.4.1.4756.20.440.20.1.333 | ColumneddPort4RxUniqueErrorEventLocal | read-only | current | EDD Series card Port4 Detailed Link OAM Statistics: Rx Unique Error Event Notificatio |
| 1.3.6.1.4.1.4756.20.440.20.1.334 | ColumneddPort4RxDuplicateErrorEventLocal | read-only | current | EDD Series card Port4 Detailed Link OAM Statistics: Rx Duplicate Error Event Notification |
| 1.3.6.1.4.1.4756.20.440.20.1.335 | ColumneddPort4RxLoopBackControlLocal | read-only | current | EDD Series card Port4 Detailed Link OAM Statistics: Rx Loopback Control |
| 1.3.6.1.4.1.4756.20.440.20.1.336 | ColumneddPort4RxVariableRequestLocal | read-only | current | EDD Series card Port4 Detailed Link OAM Statistics: Rx Variable Request |
| 1.3.6.1.4.1.4756.20.440.20.1.337 | ColumneddPort4RxVariableResponseLocal | read-only | current | EDD Series card Port4 Detailed Link OAM Statistics: Rx Variable Response |
| 1.3.6.1.4.1.4756.20.440.20.1.338 | ColumneddPort4RxOrgSpecificPDULocal | read-only | current | EDD Series card Port4 Detailed Link OAM Statistics: Rx Org Specific PDU's |
| 1.3.6.1.4.1.4756.20.440.20.1.339 | ColumneddPort4RxUnsupportedCodesLocal | read-only | current | EDD Series card Port4 Detailed Link OAM Statistics: Rx Unsupported Codes |
| 1.3.6.1.4.1.4756.20.440.20.1.340 | ColumneddPort4RxLinkFaultPDULocal | read-only | current | EDD Series card Port4 Detailed Link OAM Statistics: Rx Link Fault PDU's |
| 1.3.6.1.4.1.4756.20.440.20.1.341 | ColumneddPort4RxDyingGaspLocal | read-only | current | EDD Series card Port4 Detailed Link OAM Statistics: Rx Dying Gasp |
| 1.3.6.1.4.1.4756.20.440.20.1.342 | ColumneddPort4RxCriticalEventPDULocal | read-only | current | EDD Series card Port4 Detailed Link OAM Statistics: Rx Dying Gasp |
| 1.3.6.1.4.1.4756.20.440.20.1.343 | ColumneddPort4TxOAMInfoPDULocal | read-only | current | EDD Series card Port4 Detailed Link OAM Statistics: Tx OAM Information PDU's |
| 1.3.6.1.4.1.4756.20.440.20.1.344 | ColumneddPort4TxUniqueErrorEventLocal | read-only | current | EDD Series card Port4 Detailed Link OAM Statistics: Tx Unique Error Event Notificatio |
| 1.3.6.1.4.1.4756.20.440.20.1.345 | ColumneddPort4TxDuplicateErrorEventLocal | read-only | current | EDD Series card Port4 Detailed Link OAM Statistics: Tx Duplicate Error Event Notification |
| 1.3.6.1.4.1.4756.20.440.20.1.346 | ColumneddPort4TxLoopBackControlLocal | read-only | current | EDD Series card Port4 Detailed Link OAM Statistics: Tx Loopback Control |
| 1.3.6.1.4.1.4756.20.440.20.1.347 | ColumneddPort4TxVariableRequestLocal | read-only | current | EDD Series card Port4 Detailed Link OAM Statistics: Tx Variable Request |
| 1.3.6.1.4.1.4756.20.440.20.1.348 | ColumneddPort4TxVariableResponseLocal | read-only | current | EDD Series card Port4 Detailed Link OAM Statistics: Tx Variable Response |
| 1.3.6.1.4.1.4756.20.440.20.1.349 | ColumneddPort4TxOrgSpecificPDULocal | read-only | current | EDD Series card Port4 Detailed Link OAM Statistics: Tx Org Specific PDU's |
| 1.3.6.1.4.1.4756.20.440.20.1.350 | ColumneddPort4TxUnsupportedCodesLocal | read-only | current | EDD Series card Port4 Detailed Link OAM Statistics: Tx Unsupported Codes |
| 1.3.6.1.4.1.4756.20.440.20.1.351 | ColumneddPort4TxLinkFaultPDULocal | read-only | current | EDD Series card Port4 Detailed Link OAM Statistics: Tx Link Fault PDU's |
| 1.3.6.1.4.1.4756.20.440.20.1.352 | ColumneddPort4TxDyingGaspLocal | read-only | current | EDD Series card Port4 Detailed Link OAM Statistics: Tx Dying Gasp |
| 1.3.6.1.4.1.4756.20.440.20.1.353 | ColumneddPort4TxCriticalEventPDULocal | read-only | current | EDD Series card Port4 Detailed Link OAM Statistics: Tx Dying Gasp |
| 1.3.6.1.4.1.4756.20.440.20.1.354 | ColumneddPort1PDUPermisionLocal | read-only | current | EDD Series card Detailed Link OAM Status for Port 1: PDU Permission |
| 1.3.6.1.4.1.4756.20.440.20.1.355 | ColumneddPort1DiscoveryStateLocal | read-only | current | EDD Series card Detailed Link OAM Status for Port 1: Discovery State |
| 1.3.6.1.4.1.4756.20.440.20.1.356 | ColumneddPort1PeerMACAddrLocal | read-only | current | EDD Series card Detailed Link OAM Status for Port 1: Discovery State |
| 1.3.6.1.4.1.4756.20.440.20.1.357 | ColumneddPort1LocalModeLocal | read-only | current | EDD Series card Detailed Link OAM Status for Port 1: Local: Mode |
| 1.3.6.1.4.1.4756.20.440.20.1.358 | ColumneddPort1LocalUnOperationLocal | read-only | current | EDD Series card Detailed Link OAM Status for Port 1: Local: Unidirectional Operation Support |
| 1.3.6.1.4.1.4756.20.440.20.1.359 | ColumneddPort1LocalRemoteLbLocal | read-only | current | EDD Series card Detailed Link OAM Status for Port 1: Local: Remote Loopback Support |
| 1.3.6.1.4.1.4756.20.440.20.1.360 | ColumneddPort1LocalLMLocal | read-only | current | EDD Series card Detailed Link OAM Status for Port 1: Local: Link Monitoring Support |
| 1.3.6.1.4.1.4756.20.440.20.1.361 | ColumneddPort1LocalMIBRetrievalLocal | read-only | current | EDD Series card Detailed Link OAM Status for Port 1: Local: MIB Retrieval Support |
| 1.3.6.1.4.1.4756.20.440.20.1.362 | ColumneddPort1LocalMTUSizeLocal | read-only | current | EDD Series card Detailed Link OAM Status for Port 1: Local: MTU Size |
| 1.3.6.1.4.1.4756.20.440.20.1.363 | ColumneddPort1LocalMultiStateLocal | read-only | current | EDD Series card Detailed Link OAM Status for Port 1: Local: Multiplexer State |
| 1.3.6.1.4.1.4756.20.440.20.1.364 | ColumneddPort1LocalParserStateLocal | read-only | current | EDD Series card Detailed Link OAM Status for Port 1: Local: Multiplexer State |
| 1.3.6.1.4.1.4756.20.440.20.1.365 | ColumneddPort1LocalOUILocal | read-only | current | EDD Series card Detailed Link OAM Status for Port 1: Local: Organizational Unique Identification |
| 1.3.6.1.4.1.4756.20.440.20.1.366 | ColumneddPort1LocalPDURevLocal | read-only | current | EDD Series card Detailed Link OAM Status for Port 1: Local: PDU Revision |
| 1.3.6.1.4.1.4756.20.440.20.1.367 | ColumneddPort1PeerModeLocal | read-only | current | EDD Series card Detailed Link OAM Status for Port 1: Peer: Mode |
| 1.3.6.1.4.1.4756.20.440.20.1.368 | ColumneddPort1PeerUnOperationLocal | read-only | current | EDD Series card Detailed Link OAM Status for Port 1: Peer: Unidirectional Operation Support |
| 1.3.6.1.4.1.4756.20.440.20.1.369 | ColumneddPort1PeerRemoteLbLocal | read-only | current | EDD Series card Detailed Link OAM Status for Port 1: Peer: Remote Loopback Support |
| 1.3.6.1.4.1.4756.20.440.20.1.370 | ColumneddPort1PeerLMLocal | read-only | current | EDD Series card Detailed Link OAM Status for Port 1: Peer: Link Monitoring Support |
| 1.3.6.1.4.1.4756.20.440.20.1.371 | ColumneddPort1PeerMIBRetrievalLocal | read-only | current | EDD Series card Detailed Link OAM Status for Port 1: Peer: MIB Retrieval Support |
| 1.3.6.1.4.1.4756.20.440.20.1.372 | ColumneddPort1PeerMTUSizeLocal | read-only | current | EDD Series card Detailed Link OAM Status for Port 1: Peer: MTU Size |
| 1.3.6.1.4.1.4756.20.440.20.1.373 | ColumneddPort1PeerMultiStateLocal | read-only | current | EDD Series card Detailed Link OAM Status for Port 1: Peer: Multiplexer State |
| 1.3.6.1.4.1.4756.20.440.20.1.374 | ColumneddPort1PeerParserStateLocal | read-only | current | EDD Series card Detailed Link OAM Status for Port 1: Peer: Multiplexer State |
| 1.3.6.1.4.1.4756.20.440.20.1.375 | ColumneddPort1PeerOUILocal | read-only | current | EDD Series card Detailed Link OAM Status for Port 1: Peer: Organizational Unique Identification |
| 1.3.6.1.4.1.4756.20.440.20.1.376 | ColumneddPort1PeerPDURevLocal | read-only | current | EDD Series card Detailed Link OAM Status for Port 1: Peer: PDU Revision |
| 1.3.6.1.4.1.4756.20.440.20.1.377 | ColumneddPort2PDUPermisionLocal | read-only | current | EDD Series card Detailed Link OAM Status for Port 2: PDU Permission |
| 1.3.6.1.4.1.4756.20.440.20.1.378 | ColumneddPort2DiscoveryStateLocal | read-only | current | EDD Series card Detailed Link OAM Status for Port 2: Discovery State |
| 1.3.6.1.4.1.4756.20.440.20.1.379 | ColumneddPort2PeerMACAddrLocal | read-only | current | EDD Series card Detailed Link OAM Status for Port 2: Discovery State |
| 1.3.6.1.4.1.4756.20.440.20.1.380 | ColumneddPort2LocalModeLocal | read-only | current | EDD Series card Detailed Link OAM Status for Port 2: Local: Mode |
| 1.3.6.1.4.1.4756.20.440.20.1.381 | ColumneddPort2LocalUnOperationLocal | read-only | current | EDD Series card Detailed Link OAM Status for Port 2: Local: Unidirectional Operation Support |
| 1.3.6.1.4.1.4756.20.440.20.1.382 | ColumneddPort2LocalRemoteLbLocal | read-only | current | EDD Series card Detailed Link OAM Status for Port 2: Local: Remote Loopback Support |
| 1.3.6.1.4.1.4756.20.440.20.1.383 | ColumneddPort2LocalLMLocal | read-only | current | EDD Series card Detailed Link OAM Status for Port 2: Local: Link Monitoring Support |
| 1.3.6.1.4.1.4756.20.440.20.1.384 | ColumneddPort2LocalMIBRetrievalLocal | read-only | current | EDD Series card Detailed Link OAM Status for Port 2: Local: MIB Retrieval Support |
| 1.3.6.1.4.1.4756.20.440.20.1.385 | ColumneddPort2LocalMTUSizeLocal | read-only | current | EDD Series card Detailed Link OAM Status for Port 2: Local: MTU Size |
| 1.3.6.1.4.1.4756.20.440.20.1.386 | ColumneddPort2LocalMultiStateLocal | read-only | current | EDD Series card Detailed Link OAM Status for Port 2: Local: Multiplexer State |
| 1.3.6.1.4.1.4756.20.440.20.1.387 | ColumneddPort2LocalParserStateLocal | read-only | current | EDD Series card Detailed Link OAM Status for Port 2: Local: Multiplexer State |
| 1.3.6.1.4.1.4756.20.440.20.1.388 | ColumneddPort2LocalOUILocal | read-only | current | EDD Series card Detailed Link OAM Status for Port 2: Local: Organizational Unique Identification |
| 1.3.6.1.4.1.4756.20.440.20.1.389 | ColumneddPort2LocalPDURevLocal | read-only | current | EDD Series card Detailed Link OAM Status for Port 2: Local: PDU Revision |
| 1.3.6.1.4.1.4756.20.440.20.1.390 | ColumneddPort2PeerModeLocal | read-only | current | EDD Series card Detailed Link OAM Status for Port 2: Peer: Mode |
| 1.3.6.1.4.1.4756.20.440.20.1.391 | ColumneddPort2PeerUnOperationLocal | read-only | current | EDD Series card Detailed Link OAM Status for Port 2: Peer: Unidirectional Operation Support |
| 1.3.6.1.4.1.4756.20.440.20.1.392 | ColumneddPort2PeerRemoteLbLocal | read-only | current | EDD Series card Detailed Link OAM Status for Port 2: Peer: Remote Loopback Support |
| 1.3.6.1.4.1.4756.20.440.20.1.393 | ColumneddPort2PeerLMLocal | read-only | current | EDD Series card Detailed Link OAM Status for Port 2: Peer: Link Monitoring Support |
| 1.3.6.1.4.1.4756.20.440.20.1.394 | ColumneddPort2PeerMIBRetrievalLocal | read-only | current | EDD Series card Detailed Link OAM Status for Port 2: Peer: MIB Retrieval Support |
| 1.3.6.1.4.1.4756.20.440.20.1.395 | ColumneddPort2PeerMTUSizeLocal | read-only | current | EDD Series card Detailed Link OAM Status for Port 2: Peer: MTU Size |
| 1.3.6.1.4.1.4756.20.440.20.1.396 | ColumneddPort2PeerMultiStateLocal | read-only | current | EDD Series card Detailed Link OAM Status for Port 2: Peer: Multiplexer State |
| 1.3.6.1.4.1.4756.20.440.20.1.397 | ColumneddPort2PeerParserStateLocal | read-only | current | EDD Series card Detailed Link OAM Status for Port 2: Peer: Multiplexer State |
| 1.3.6.1.4.1.4756.20.440.20.1.398 | ColumneddPort2PeerOUILocal | read-only | current | EDD Series card Detailed Link OAM Status for Port 2: Peer: Organizational Unique Identification |
| 1.3.6.1.4.1.4756.20.440.20.1.399 | ColumneddPort2PeerPDURevLocal | read-only | current | EDD Series card Detailed Link OAM Status for Port 2: Peer: PDU Revision |
| 1.3.6.1.4.1.4756.20.440.20.1.400 | ColumneddPort3PDUPermisionLocal | read-only | current | EDD Series card Detailed Link OAM Status for Port 3: PDU Permission |
| 1.3.6.1.4.1.4756.20.440.20.1.401 | ColumneddPort3DiscoveryStateLocal | read-only | current | EDD Series card Detailed Link OAM Status for Port 3: Discovery State |
| 1.3.6.1.4.1.4756.20.440.20.1.402 | ColumneddPort3PeerMACAddrLocal | read-only | current | EDD Series card Detailed Link OAM Status for Port 3: Discovery State |
| 1.3.6.1.4.1.4756.20.440.20.1.403 | ColumneddPort3LocalModeLocal | read-only | current | EDD Series card Detailed Link OAM Status for Port 3: Local: Mode |
| 1.3.6.1.4.1.4756.20.440.20.1.404 | ColumneddPort3LocalUnOperationLocal | read-only | current | EDD Series card Detailed Link OAM Status for Port 3: Local: Unidirectional Operation Support |
| 1.3.6.1.4.1.4756.20.440.20.1.405 | ColumneddPort3LocalRemoteLbLocal | read-only | current | EDD Series card Detailed Link OAM Status for Port 3: Local: Remote Loopback Support |
| 1.3.6.1.4.1.4756.20.440.20.1.406 | ColumneddPort3LocalLMLocal | read-only | current | EDD Series card Detailed Link OAM Status for Port 3: Local: Link Monitoring Support |
| 1.3.6.1.4.1.4756.20.440.20.1.407 | ColumneddPort3LocalMIBRetrievalLocal | read-only | current | EDD Series card Detailed Link OAM Status for Port 3: Local: MIB Retrieval Support |
| 1.3.6.1.4.1.4756.20.440.20.1.408 | ColumneddPort3LocalMTUSizeLocal | read-only | current | EDD Series card Detailed Link OAM Status for Port 3: Local: MTU Size |
| 1.3.6.1.4.1.4756.20.440.20.1.409 | ColumneddPort3LocalMultiStateLocal | read-only | current | EDD Series card Detailed Link OAM Status for Port 3: Local: Multiplexer State |
| 1.3.6.1.4.1.4756.20.440.20.1.410 | ColumneddPort3LocalParserStateLocal | read-only | current | EDD Series card Detailed Link OAM Status for Port 3: Local: Multiplexer State |
| 1.3.6.1.4.1.4756.20.440.20.1.411 | ColumneddPort3LocalOUILocal | read-only | current | EDD Series card Detailed Link OAM Status for Port 3: Local: Organizational Unique Identification |
| 1.3.6.1.4.1.4756.20.440.20.1.412 | ColumneddPort3LocalPDURevLocal | read-only | current | EDD Series card Detailed Link OAM Status for Port 3: Local: PDU Revision |
| 1.3.6.1.4.1.4756.20.440.20.1.413 | ColumneddPort3PeerModeLocal | read-only | current | EDD Series card Detailed Link OAM Status for Port 3: Peer: Mode |
| 1.3.6.1.4.1.4756.20.440.20.1.414 | ColumneddPort3PeerUnOperationLocal | read-only | current | EDD Series card Detailed Link OAM Status for Port 3: Peer: Unidirectional Operation Support |
| 1.3.6.1.4.1.4756.20.440.20.1.415 | ColumneddPort3PeerRemoteLbLocal | read-only | current | EDD Series card Detailed Link OAM Status for Port 3: Peer: Remote Loopback Support |
| 1.3.6.1.4.1.4756.20.440.20.1.416 | ColumneddPort3PeerLMLocal | read-only | current | EDD Series card Detailed Link OAM Status for Port 3: Peer: Link Monitoring Support |
| 1.3.6.1.4.1.4756.20.440.20.1.417 | ColumneddPort3PeerMIBRetrievalLocal | read-only | current | EDD Series card Detailed Link OAM Status for Port 3: Peer: MIB Retrieval Support |
| 1.3.6.1.4.1.4756.20.440.20.1.418 | ColumneddPort3PeerMTUSizeLocal | read-only | current | EDD Series card Detailed Link OAM Status for Port 3: Peer: MTU Size |
| 1.3.6.1.4.1.4756.20.440.20.1.419 | ColumneddPort3PeerMultiStateLocal | read-only | current | EDD Series card Detailed Link OAM Status for Port 3: Peer: Multiplexer State |
| 1.3.6.1.4.1.4756.20.440.20.1.420 | ColumneddPort3PeerParserStateLocal | read-only | current | EDD Series card Detailed Link OAM Status for Port 3: Peer: Multiplexer State |
| 1.3.6.1.4.1.4756.20.440.20.1.421 | ColumneddPort3PeerOUILocal | read-only | current | EDD Series card Detailed Link OAM Status for Port 3: Peer: Organizational Unique Identification |
| 1.3.6.1.4.1.4756.20.440.20.1.422 | ColumneddPort3PeerPDURevLocal | read-only | current | EDD Series card Detailed Link OAM Status for Port 3: Peer: PDU Revision |
| 1.3.6.1.4.1.4756.20.440.20.1.423 | ColumneddPort4PDUPermisionLocal | read-only | current | EDD Series card Detailed Link OAM Status for Port 4: PDU Permission |
| 1.3.6.1.4.1.4756.20.440.20.1.424 | ColumneddPort4DiscoveryStateLocal | read-only | current | EDD Series card Detailed Link OAM Status for Port 4: Discovery State |
| 1.3.6.1.4.1.4756.20.440.20.1.425 | ColumneddPort4PeerMACAddrLocal | read-only | current | EDD Series card Detailed Link OAM Status for Port 4: Discovery State |
| 1.3.6.1.4.1.4756.20.440.20.1.426 | ColumneddPort4LocalModeLocal | read-only | current | EDD Series card Detailed Link OAM Status for Port 4: Local: Mode |
| 1.3.6.1.4.1.4756.20.440.20.1.427 | ColumneddPort4LocalUnOperationLocal | read-only | current | EDD Series card Detailed Link OAM Status for Port 4: Local: Unidirectional Operation Support |
| 1.3.6.1.4.1.4756.20.440.20.1.428 | ColumneddPort4LocalRemoteLbLocal | read-only | current | EDD Series card Detailed Link OAM Status for Port 4: Local: Remote Loopback Support |
| 1.3.6.1.4.1.4756.20.440.20.1.429 | ColumneddPort4LocalLMLocal | read-only | current | EDD Series card Detailed Link OAM Status for Port 4: Local: Link Monitoring Support |
| 1.3.6.1.4.1.4756.20.440.20.1.430 | ColumneddPort4LocalMIBRetrievalLocal | read-only | current | EDD Series card Detailed Link OAM Status for Port 4: Local: MIB Retrieval Support |
| 1.3.6.1.4.1.4756.20.440.20.1.431 | ColumneddPort4LocalMTUSizeLocal | read-only | current | EDD Series card Detailed Link OAM Status for Port 4: Local: MTU Size |
| 1.3.6.1.4.1.4756.20.440.20.1.432 | ColumneddPort4LocalMultiStateLocal | read-only | current | EDD Series card Detailed Link OAM Status for Port 4: Local: Multiplexer State |
| 1.3.6.1.4.1.4756.20.440.20.1.433 | ColumneddPort4LocalParserStateLocal | read-only | current | EDD Series card Detailed Link OAM Status for Port 4: Local: Multiplexer State |
| 1.3.6.1.4.1.4756.20.440.20.1.434 | ColumneddPort4LocalOUILocal | read-only | current | EDD Series card Detailed Link OAM Status for Port 4: Local: Organizational Unique Identification |
| 1.3.6.1.4.1.4756.20.440.20.1.435 | ColumneddPort4LocalPDURevLocal | read-only | current | EDD Series card Detailed Link OAM Status for Port 4: Local: PDU Revision |
| 1.3.6.1.4.1.4756.20.440.20.1.436 | ColumneddPort4PeerModeLocal | read-only | current | EDD Series card Detailed Link OAM Status for Port 4: Peer: Mode |
| 1.3.6.1.4.1.4756.20.440.20.1.437 | ColumneddPort4PeerUnOperationLocal | read-only | current | EDD Series card Detailed Link OAM Status for Port 4: Peer: Unidirectional Operation Support |
| 1.3.6.1.4.1.4756.20.440.20.1.438 | ColumneddPort4PeerRemoteLbLocal | read-only | current | EDD Series card Detailed Link OAM Status for Port 4: Peer: Remote Loopback Support |
| 1.3.6.1.4.1.4756.20.440.20.1.439 | ColumneddPort4PeerLMLocal | read-only | current | EDD Series card Detailed Link OAM Status for Port 4: Peer: Link Monitoring Support |
| 1.3.6.1.4.1.4756.20.440.20.1.440 | ColumneddPort4PeerMIBRetrievalLocal | read-only | current | EDD Series card Detailed Link OAM Status for Port 4: Peer: MIB Retrieval Support |
| 1.3.6.1.4.1.4756.20.440.20.1.441 | ColumneddPort4PeerMTUSizeLocal | read-only | current | EDD Series card Detailed Link OAM Status for Port 4: Peer: MTU Size |
| 1.3.6.1.4.1.4756.20.440.20.1.442 | ColumneddPort4PeerMultiStateLocal | read-only | current | EDD Series card Detailed Link OAM Status for Port 4: Peer: Multiplexer State |
| 1.3.6.1.4.1.4756.20.440.20.1.443 | ColumneddPort4PeerParserStateLocal | read-only | current | EDD Series card Detailed Link OAM Status for Port 4: Peer: Multiplexer State |
| 1.3.6.1.4.1.4756.20.440.20.1.444 | ColumneddPort4PeerOUILocal | read-only | current | EDD Series card Detailed Link OAM Status for Port 4: Peer: Organizational Unique Identification |
| 1.3.6.1.4.1.4756.20.440.20.1.445 | ColumneddPort4PeerPDURevLocal | read-only | current | EDD Series card Detailed Link OAM Status for Port 4: Peer: PDU Revision |
| 1.3.6.1.4.1.4756.20.440.20.1.446 | ColumneddCLEAROAMCOUNTERLocal | read-write | current | EDD Series card Clear OAM Counter: 0: Off 1: Action |
| 1.3.6.1.4.1.4756.20.440.20.1.447 | ColumneddLoopProtectionEnableLocal | read-write | current | EDD Series card Loop Protection Configuration: General Settings - Enable Loop Protection 0: Disable 1: Enable |
| 1.3.6.1.4.1.4756.20.440.20.1.448 | ColumneddLoopProtectionTxTimeLocal | read-write | current | EDD Series card Loop Protection Configuration: General Settings - Transmission Time |
| 1.3.6.1.4.1.4756.20.440.20.1.449 | ColumneddLoopProtectionShutdownTimeLocal | read-write | current | EDD Series card Loop Protection Configuration: General Settings - Shutdown Time |
| 1.3.6.1.4.1.4756.20.440.20.1.450 | ColumneddLoopProtectionPort1EnabledLocal | read-write | current | EDD Series card Loop Protection Configuration for Port 1: Port Configuration - Enable 0: Disable 1: Enable |
| 1.3.6.1.4.1.4756.20.440.20.1.451 | ColumneddLoopProtectionPort1ActionLocal | read-write | current | EDD Series card Loop Protection Configuration for Port 1: Port Configuration - Action 0: Shutdown Port 1: Shutdown Port And Log 2: Log Only |
| 1.3.6.1.4.1.4756.20.440.20.1.452 | ColumneddLoopProtectionPort1TxModeLocal | read-write | current | EDD Series card Loop Protection Configuration for Port 1: Port Configuration - Tx Mode 0: Disable 1: Enable |
| 1.3.6.1.4.1.4756.20.440.20.1.453 | ColumneddLoopProtectionPort2EnabledLocal | read-write | current | EDD Series card Loop Protection Configuration for Port 2: Port Configuration - Enable 0: Disable 1: Enable |
| 1.3.6.1.4.1.4756.20.440.20.1.454 | ColumneddLoopProtectionPort2ActionLocal | read-write | current | EDD Series card Loop Protection Configuration for Port 2: Port Configuration - Action 0: Shutdown Port 1: Shutdown Port And Log 2: Log Only |
| 1.3.6.1.4.1.4756.20.440.20.1.455 | ColumneddLoopProtectionPort2TxModeLocal | read-write | current | EDD Series card Loop Protection Configuration for Port 2: Port Configuration - Tx Mode 0: Disable 1: Enable |
| 1.3.6.1.4.1.4756.20.440.20.1.456 | ColumneddLoopProtectionPort3EnabledLocal | read-write | current | EDD Series card Loop Protection Configuration for Port 3: Port Configuration - Enable 0: Disable 1: Enable |
| 1.3.6.1.4.1.4756.20.440.20.1.457 | ColumneddLoopProtectionPort3ActionLocal | read-write | current | EDD Series card Loop Protection Configuration for Port 3: Port Configuration - Action 0: Shutdown Port 1: Shutdown Port And Log 2: Log Only |
| 1.3.6.1.4.1.4756.20.440.20.1.458 | ColumneddLoopProtectionPort3TxModeLocal | read-write | current | EDD Series card Loop Protection Configuration for Port 3: Port Configuration - Tx Mode 0: Disable 1: Enable |
| 1.3.6.1.4.1.4756.20.440.20.1.459 | ColumneddLoopProtectionPort4EnabledLocal | read-write | current | EDD Series card Loop Protection Configuration for Port 4: Port Configuration - Enable 0: Disable 1: Enable |
| 1.3.6.1.4.1.4756.20.440.20.1.460 | ColumneddLoopProtectionPort4ActionLocal | read-write | current | EDD Series card Loop Protection Configuration for Port 4: Port Configuration - Action 0: Shutdown Port 1: Shutdown Port And Log 2: Log Only |
| 1.3.6.1.4.1.4756.20.440.20.1.461 | ColumneddLoopProtectionPort4TxModeLocal | read-write | current | EDD Series card Loop Protection Configuration for Port 41: Port Configuration - Tx Mode 0: Disable 1: Enable |
| 1.3.6.1.4.1.4756.20.440.20.1.462 | ColumneddLoopProtectionPort1ActionStsLocal | read-only | current | EDD Series card Loop Protection Status for Port 1: Action |
| 1.3.6.1.4.1.4756.20.440.20.1.463 | ColumneddLoopProtectionPort1TransStsLocal | read-only | current | EDD Series card Loop Protection Status for Port 1: Transmit |
| 1.3.6.1.4.1.4756.20.440.20.1.464 | ColumneddLoopProtectionPort1LoopsStsLocal | read-only | current | EDD Series card Loop Protection Status for Port 1: Loops |
| 1.3.6.1.4.1.4756.20.440.20.1.465 | ColumneddLoopProtectionPort1StatusLocal | read-only | current | EDD Series card Loop Protection Status for Port 1: Status |
| 1.3.6.1.4.1.4756.20.440.20.1.466 | ColumneddLoopProtectionPort1LoopStsLocal | read-only | current | EDD Series card Loop Protection Status for Port 1: Loop |
| 1.3.6.1.4.1.4756.20.440.20.1.467 | ColumneddLoopProtectionPort1TimeOfLastLoopLocal | read-only | current | EDD Series card Loop Protection Status for Port 1: Time of Last Loop |
| 1.3.6.1.4.1.4756.20.440.20.1.468 | ColumneddLoopProtectionPort2ActionStsLocal | read-only | current | EDD Series card Loop Protection Status for Port 2: Action |
| 1.3.6.1.4.1.4756.20.440.20.1.469 | ColumneddLoopProtectionPort2TransStsLocal | read-only | current | EDD Series card Loop Protection Status for Port 2: Transmit |
| 1.3.6.1.4.1.4756.20.440.20.1.470 | ColumneddLoopProtectionPort2LoopsStsLocal | read-only | current | EDD Series card Loop Protection Status for Port 2: Loops |
| 1.3.6.1.4.1.4756.20.440.20.1.471 | ColumneddLoopProtectionPort2StatusLocal | read-only | current | EDD Series card Loop Protection Status for Port 2: Status |
| 1.3.6.1.4.1.4756.20.440.20.1.472 | ColumneddLoopProtectionPort2LoopStsLocal | read-only | current | EDD Series card Loop Protection Status for Port 2: Loop |
| 1.3.6.1.4.1.4756.20.440.20.1.473 | ColumneddLoopProtectionPort2TimeOfLastLoopLocal | read-only | current | EDD Series card Loop Protection Status for Port 2: Time of Last Loop |
| 1.3.6.1.4.1.4756.20.440.20.1.474 | ColumneddLoopProtectionPort3ActionStsLocal | read-only | current | EDD Series card Loop Protection Status for Port 3: Action |
| 1.3.6.1.4.1.4756.20.440.20.1.475 | ColumneddLoopProtectionPort3TransStsLocal | read-only | current | EDD Series card Loop Protection Status for Port 3: Transmit |
| 1.3.6.1.4.1.4756.20.440.20.1.476 | ColumneddLoopProtectionPort3LoopsStsLocal | read-only | current | EDD Series card Loop Protection Status for Port 3: Loops |
| 1.3.6.1.4.1.4756.20.440.20.1.477 | ColumneddLoopProtectionPort3StatusLocal | read-only | current | EDD Series card Loop Protection Status for Port 3: Status |
| 1.3.6.1.4.1.4756.20.440.20.1.478 | ColumneddLoopProtectionPort3LoopStsLocal | read-only | current | EDD Series card Loop Protection Status for Port 3: Loop |
| 1.3.6.1.4.1.4756.20.440.20.1.479 | ColumneddLoopProtectionPort3TimeOfLastLoopLocal | read-only | current | EDD Series card Loop Protection Status for Port 3: Time of Last Loop |
| 1.3.6.1.4.1.4756.20.440.20.1.480 | ColumneddLoopProtectionPort4ActionStsLocal | read-only | current | EDD Series card Loop Protection Status for Port 4: Action |
| 1.3.6.1.4.1.4756.20.440.20.1.481 | ColumneddLoopProtectionPort4TransStsLocal | read-only | current | EDD Series card Loop Protection Status for Port 4: Transmit |
| 1.3.6.1.4.1.4756.20.440.20.1.482 | ColumneddLoopProtectionPort4LoopsStsLocal | read-only | current | EDD Series card Loop Protection Status for Port 4: Loops |
| 1.3.6.1.4.1.4756.20.440.20.1.483 | ColumneddLoopProtectionPort4StatusLocal | read-only | current | EDD Series card Loop Protection Status for Port 4: Status |
| 1.3.6.1.4.1.4756.20.440.20.1.484 | ColumneddLoopProtectionPort4LoopStsLocal | read-only | current | EDD Series card Loop Protection Status for Port 4: Loop |
| 1.3.6.1.4.1.4756.20.440.20.1.485 | ColumneddLoopProtectionPort4TimeOfLastLoopLocal | read-only | current | EDD Series card Loop Protection Status for Port 4: Time of Last Loop |
| 1.3.6.1.4.1.4756.20.440.20.1.486 | ColumneddSTPProtocolVersionLocal | read-write | current | EDD Series card STP Bridge Configuration: Basic Settings - Protocol Version 0: STP 1: RSTP 2: MSTP |
| 1.3.6.1.4.1.4756.20.440.20.1.487 | ColumneddSTPBridgePriorityLocal | read-write | current | EDD Series card STP Bridge Configuration: Basic Settings - Bridge Priority 0: 0 1: 4096 2: 8192 3: 12288 4: 16384 5: 20480 6: 24576 7: 28672 8: 32768 9: 36864 … |
| 1.3.6.1.4.1.4756.20.440.20.1.488 | ColumneddSTPForwardDelayLocal | read-write | current | EDD Series card STP Bridge Configuration: Basic Settings - Forward Delay |
| 1.3.6.1.4.1.4756.20.440.20.1.489 | ColumneddSTPMaxAgeLocal | read-write | current | EDD Series card STP Bridge Configuration: Basic Settings - Max Age |
| 1.3.6.1.4.1.4756.20.440.20.1.490 | ColumneddSTPMaximumHopCountLocal | read-write | current | EDD Series card STP Bridge Configuration: Basic Settings - Maximum Hop Count |
| 1.3.6.1.4.1.4756.20.440.20.1.491 | ColumneddSTPTransmitHoldCountLocal | read-write | current | EDD Series card STP Bridge Configuration: Basic Settings - Transmit Hold Count |
| 1.3.6.1.4.1.4756.20.440.20.1.492 | ColumneddSTPEdgePortBPDUFilteringLocal | read-write | current | EDD Series card STP Bridge Configuration: Advanced Settings - Edge Port BPDU Filtering 0: Off 1: On |
| 1.3.6.1.4.1.4756.20.440.20.1.493 | ColumneddSTPEdgePortBPDUGuardLocal | read-write | current | EDD Series card STP Bridge Configuration: Advanced Settings - Edge Port BPDU Guard 0: Off 1: On |
| 1.3.6.1.4.1.4756.20.440.20.1.494 | ColumneddSTPPortErrorRecoveryTimeoutLocal | read-write | current | EDD Series card STP Bridge Configuration: Advanced Settings - Port Error Recovery Timeout 0: Off 1: On |
| 1.3.6.1.4.1.4756.20.440.20.1.495 | ColumneddMSTIConfigurationNameLocal | read-write | current | EDD Series card MSTI Configuration: Configuration Identification - Configuration Name |
| 1.3.6.1.4.1.4756.20.440.20.1.496 | ColumneddMSTIConfigurationRevisionLocal | read-write | current | EDD Series card MSTI Configuration: Configuration Identification - Configuration Revision |
| 1.3.6.1.4.1.4756.20.440.20.1.497 | ColumneddMSTI1VLANsMappingLocal | read-write | current | EDD Series card MSTI Configuration: MSTI Mapping - MSTI 1 |
| 1.3.6.1.4.1.4756.20.440.20.1.498 | ColumneddMSTI2VLANsMappingLocal | read-write | current | EDD Series card MSTI Configuration: MSTI Mapping - MSTI 2 |
| 1.3.6.1.4.1.4756.20.440.20.1.499 | ColumneddMSTI3VLANsMappingLocal | read-write | current | EDD Series card MSTI Configuration: MSTI Mapping - MSTI 3 |
| 1.3.6.1.4.1.4756.20.440.20.1.500 | ColumneddMSTI4VLANsMappingLocal | read-write | current | EDD Series card MSTI Configuration: MSTI Mapping - MSTI 4 |
| 1.3.6.1.4.1.4756.20.440.20.1.501 | ColumneddMSTI5VLANsMappingLocal | read-write | current | EDD Series card MSTI Configuration: MSTI Mapping - MSTI 5 |
| 1.3.6.1.4.1.4756.20.440.20.1.502 | ColumneddMSTI6VLANsMappingLocal | read-write | current | EDD Series card MSTI Configuration: MSTI Mapping - MSTI 6 |
| 1.3.6.1.4.1.4756.20.440.20.1.503 | ColumneddMSTI7VLANsMappingLocal | read-write | current | EDD Series card MSTI Configuration: MSTI Mapping - MSTI 7 |
| 1.3.6.1.4.1.4756.20.440.20.1.504 | ColumneddCISTAggregatedSTPEnabledLocal | read-write | current | EDD Series card STP CIST Port Configuration: CIST Aggregated Port Configuration - STP Enabled |
| 1.3.6.1.4.1.4756.20.440.20.1.505 | ColumneddCISTAggregatedPathCostLocal | read-write | current | EDD Series card STP CIST Port Configuration: CIST Aggregated Port Configuration - Path Cost Valid values are in the range 0 to 200000000. Setting 0 means Auto … |
| 1.3.6.1.4.1.4756.20.440.20.1.506 | ColumneddCISTAggregatedPriorityLocal | read-write | current | EDD Series card STP CIST Port Configuration: CIST Aggregated Port Configuration - Priority |
| 1.3.6.1.4.1.4756.20.440.20.1.507 | ColumneddCISTAggregatedAdminEdgeLocal | read-write | current | EDD Series card STP CIST Port Configuration: CIST Aggregated Port Configuration - STP Enabled 0: Non-edge 1: Edge |
| 1.3.6.1.4.1.4756.20.440.20.1.508 | ColumneddCISTAggregatedAutoEdgeLocal | read-write | current | EDD Series card STP CIST Port Configuration: CIST Aggregated Port Configuration - Auto Edge 0: Non-edge 1: Edge |
| 1.3.6.1.4.1.4756.20.440.20.1.509 | ColumneddCISTAggregatedRestrictedRoleLocal | read-write | current | EDD Series card STP CIST Port Configuration: CIST Aggregated Port Configuration - Restricted Role 0: Non-edge 1: Edge |
| 1.3.6.1.4.1.4756.20.440.20.1.510 | ColumneddCISTAggregatedRestrictedTCNLocal | read-write | current | EDD Series card STP CIST Port Configuration: CIST Aggregated Port Configuration - Restricted TCN 0: Non-edge 1: Edge |
| 1.3.6.1.4.1.4756.20.440.20.1.511 | ColumneddCISTAggregatedBPDUGuardLocal | read-write | current | EDD Series card STP CIST Port Configuration: CIST Aggregated Port Configuration - BPDU Guard 0: Non-edge 1: Edge |
| 1.3.6.1.4.1.4756.20.440.20.1.512 | ColumneddCISTAggregatedPointToPointLocal | read-write | current | EDD Series card STP CIST Port Configuration: CIST Aggregated Port Configuration - Point-to-point 0: Forced True 1: Forced False 2: Auto |
| 1.3.6.1.4.1.4756.20.440.20.1.513 | ColumneddCISTPort1STPEnabledLocal | read-write | current | EDD Series card STP CIST Port Configuration: CIST Normal Port1 Configuration - STP Enabled |
| 1.3.6.1.4.1.4756.20.440.20.1.514 | ColumneddCISTPort1PathCostLocal | read-write | current | EDD Series card STP CIST Port Configuration: CIST Normal Port1 Configuration - Path Cost Valid values are in the range 0 to 200000000. Setting 0 means Auto pat… |
| 1.3.6.1.4.1.4756.20.440.20.1.515 | ColumneddCISTPort1PriorityLocal | read-write | current | EDD Series card STP CIST Port Configuration: CIST Normal Port1 Configuration - Priority |
| 1.3.6.1.4.1.4756.20.440.20.1.516 | ColumneddCISTPort1AdminEdgeLocal | read-write | current | EDD Series card STP CIST Port Configuration: CIST Normal Port1 Configuration - STP Enabled 0: Non-edge 1: Edge |
| 1.3.6.1.4.1.4756.20.440.20.1.517 | ColumneddCISTPort1AutoEdgeLocal | read-write | current | EDD Series card STP CIST Port Configuration: CIST Normal Port1 Configuration - Auto Edge 0: Non-edge 1: Edge |
| 1.3.6.1.4.1.4756.20.440.20.1.518 | ColumneddCISTPort1RestrictedRoleLocal | read-write | current | EDD Series card STP CIST Port Configuration: CIST Normal Port1 Configuration - Restricted Role 0: Non-edge 1: Edge |
| 1.3.6.1.4.1.4756.20.440.20.1.519 | ColumneddCISTPort1RestrictedTCNLocal | read-write | current | EDD Series card STP CIST Port Configuration: CIST Normal Port1 Configuration - Restricted TCN 0: Non-edge 1: Edge |
| 1.3.6.1.4.1.4756.20.440.20.1.520 | ColumneddCISTPort1BPDUGuardLocal | read-write | current | EDD Series card STP CIST Port Configuration: CIST Normal Port1 Configuration - BPDU Guard 0: Non-edge 1: Edge |
| 1.3.6.1.4.1.4756.20.440.20.1.521 | ColumneddCISTPort1PointToPointLocal | read-write | current | EDD Series card STP CIST Port Configuration: CIST Normal Port1 Configuration - Point-to-point 0: Forced True 1: Forced False 2: Auto |
| 1.3.6.1.4.1.4756.20.440.20.1.522 | ColumneddCISTPort2STPEnabledLocal | read-write | current | EDD Series card STP CIST Port Configuration: CIST Normal Port2 Configuration - STP Enabled |
| 1.3.6.1.4.1.4756.20.440.20.1.523 | ColumneddCISTPort2PathCostLocal | read-write | current | EDD Series card STP CIST Port Configuration: CIST Normal Port2 Configuration - Path Cost Valid values are in the range 0 to 200000000. Setting 0 means Auto pat… |
| 1.3.6.1.4.1.4756.20.440.20.1.524 | ColumneddCISTPort2PriorityLocal | read-write | current | EDD Series card STP CIST Port Configuration: CIST Normal Port2 Configuration - Priority |
| 1.3.6.1.4.1.4756.20.440.20.1.525 | ColumneddCISTPort2AdminEdgeLocal | read-write | current | EDD Series card STP CIST Port Configuration: CIST Normal Port2 Configuration - STP Enabled 0: Non-edge 1: Edge |
| 1.3.6.1.4.1.4756.20.440.20.1.526 | ColumneddCISTPort2AutoEdgeLocal | read-write | current | EDD Series card STP CIST Port Configuration: CIST Normal Port2 Configuration - Auto Edge 0: Non-edge 1: Edge |
| 1.3.6.1.4.1.4756.20.440.20.1.527 | ColumneddCISTPort2RestrictedRoleLocal | read-write | current | EDD Series card STP CIST Port Configuration: CIST Normal Port2 Configuration - Restricted Role 0: Non-edge 1: Edge |
| 1.3.6.1.4.1.4756.20.440.20.1.528 | ColumneddCISTPort2RestrictedTCNLocal | read-write | current | EDD Series card STP CIST Port Configuration: CIST Normal Port2 Configuration - Restricted TCN 0: Non-edge 1: Edge |
| 1.3.6.1.4.1.4756.20.440.20.1.529 | ColumneddCISTPort2BPDUGuardLocal | read-write | current | EDD Series card STP CIST Port Configuration: CIST Normal Port2 Configuration - BPDU Guard 0: Non-edge 1: Edge |
| 1.3.6.1.4.1.4756.20.440.20.1.530 | ColumneddCISTPort2PointToPointLocal | read-write | current | EDD Series card STP CIST Port Configuration: CIST Normal Port2 Configuration - Point-to-point 0: Forced True 1: Forced False 2: Auto |
| 1.3.6.1.4.1.4756.20.440.20.1.531 | ColumneddCISTPort3STPEnabledLocal | read-write | current | EDD Series card STP CIST Port Configuration: CIST Normal Port3 Configuration - STP Enabled |
| 1.3.6.1.4.1.4756.20.440.20.1.532 | ColumneddCISTPort3PathCostLocal | read-write | current | EDD Series card STP CIST Port Configuration: CIST Normal Port3 Configuration - Path Cost Valid values are in the range 0 to 200000000. Setting 0 means Auto pat… |
| 1.3.6.1.4.1.4756.20.440.20.1.533 | ColumneddCISTPort3PriorityLocal | read-write | current | EDD Series card STP CIST Port Configuration: CIST Normal Port3 Configuration - Priority |
| 1.3.6.1.4.1.4756.20.440.20.1.534 | ColumneddCISTPort3AdminEdgeLocal | read-write | current | EDD Series card STP CIST Port Configuration: CIST Normal Port3 Configuration - STP Enabled 0: Non-edge 1: Edge |
| 1.3.6.1.4.1.4756.20.440.20.1.535 | ColumneddCISTPort3AutoEdgeLocal | read-write | current | EDD Series card STP CIST Port Configuration: CIST Normal Port3 Configuration - Auto Edge 0: Non-edge 1: Edge |
| 1.3.6.1.4.1.4756.20.440.20.1.536 | ColumneddCISTPort3RestrictedRoleLocal | read-write | current | EDD Series card STP CIST Port Configuration: CIST Normal Port3 Configuration - Restricted Role 0: Non-edge 1: Edge |
| 1.3.6.1.4.1.4756.20.440.20.1.537 | ColumneddCISTPort3RestrictedTCNLocal | read-write | current | EDD Series card STP CIST Port Configuration: CIST Normal Port3 Configuration - Restricted TCN 0: Non-edge 1: Edge |
| 1.3.6.1.4.1.4756.20.440.20.1.538 | ColumneddCISTPort3BPDUGuardLocal | read-write | current | EDD Series card STP CIST Port Configuration: CIST Normal Port3 Configuration - BPDU Guard 0: Non-edge 1: Edge |
| 1.3.6.1.4.1.4756.20.440.20.1.539 | ColumneddCISTPort3PointToPointLocal | read-write | current | EDD Series card STP CIST Port Configuration: CIST Normal Port3 Configuration - Point-to-point 0: Forced True 1: Forced False 2: Auto |
| 1.3.6.1.4.1.4756.20.440.20.1.540 | ColumneddCISTPort4STPEnabledLocal | read-write | current | EDD Series card STP CIST Port Configuration: CIST Normal Port4 Configuration - STP Enabled |
| 1.3.6.1.4.1.4756.20.440.20.1.541 | ColumneddCISTPort4PathCostLocal | read-write | current | EDD Series card STP CIST Port Configuration: CIST Normal Port4 Configuration - Path Cost Valid values are in the range 0 to 200000000. Setting 0 means Auto pat… |
| 1.3.6.1.4.1.4756.20.440.20.1.542 | ColumneddCISTPort4PriorityLocal | read-write | current | EDD Series card STP CIST Port Configuration: CIST Normal Port4 Configuration - Priority |
| 1.3.6.1.4.1.4756.20.440.20.1.543 | ColumneddCISTPort4AdminEdgeLocal | read-write | current | EDD Series card STP CIST Port Configuration: CIST Normal Port4 Configuration - STP Enabled 0: Non-edge 1: Edge |
| 1.3.6.1.4.1.4756.20.440.20.1.544 | ColumneddCISTPort4AutoEdgeLocal | read-write | current | EDD Series card STP CIST Port Configuration: CIST Normal Port4 Configuration - Auto Edge 0: Non-edge 1: Edge |
| 1.3.6.1.4.1.4756.20.440.20.1.545 | ColumneddCISTPort4RestrictedRoleLocal | read-write | current | EDD Series card STP CIST Port Configuration: CIST Normal Port4 Configuration - Restricted Role 0: Non-edge 1: Edge |
| 1.3.6.1.4.1.4756.20.440.20.1.546 | ColumneddCISTPort4RestrictedTCNLocal | read-write | current | EDD Series card STP CIST Port Configuration: CIST Normal Port4 Configuration - Restricted TCN 0: Non-edge 1: Edge |
| 1.3.6.1.4.1.4756.20.440.20.1.547 | ColumneddCISTPort4BPDUGuardLocal | read-write | current | EDD Series card STP CIST Port Configuration: CIST Normal Port4 Configuration - BPDU Guard 0: Non-edge 1: Edge |
| 1.3.6.1.4.1.4756.20.440.20.1.548 | ColumneddCISTPort4PointToPointLocal | read-write | current | EDD Series card STP CIST Port Configuration: CIST Normal Port4 Configuration - Point-to-point 0: Forced True 1: Forced False 2: Auto |
| 1.3.6.1.4.1.4756.20.440.20.1.549 | ColumneddMSTI1AggregatedPathCostLocal | read-write | current | EDD Series card MSTI Port Configuration: MSTI1 Aggregated Ports Configuration - Path Cost Valid values are in the range 0 to 200000000. Setting 0 means Auto pa… |
| 1.3.6.1.4.1.4756.20.440.20.1.550 | ColumneddMSTI1AggregatedPriorityLocal | read-write | current | EDD Series card MSTI Port Configuration: MSTI1 Aggregated Ports Configuration - Priority |
| 1.3.6.1.4.1.4756.20.440.20.1.551 | ColumneddMSTI1Port1PathCostLocal | read-write | current | EDD Series card MSTI Port Configuration: MSTI1 Normal Port1 Configuration - Path Cost Valid values are in the range 0 to 200000000. Setting 0 means Auto path c… |
| 1.3.6.1.4.1.4756.20.440.20.1.552 | ColumneddMSTI1Port1PriorityLocal | read-write | current | EDD Series card MSTI Port Configuration: MSTI1 Normal Port1 Configuration - Priority |
| 1.3.6.1.4.1.4756.20.440.20.1.553 | ColumneddMSTI1Port2PathCostLocal | read-write | current | EDD Series card MSTI Port Configuration: MSTI1 Normal Port2 Configuration - Path Cost Valid values are in the range 0 to 200000000. Setting 0 means Auto path c… |
| 1.3.6.1.4.1.4756.20.440.20.1.554 | ColumneddMSTI1Port2PriorityLocal | read-write | current | EDD Series card MSTI Port Configuration: MSTI1 Normal Port2 Configuration - Priority |
| 1.3.6.1.4.1.4756.20.440.20.1.555 | ColumneddMSTI1Port3PathCostLocal | read-write | current | EDD Series card MSTI Port Configuration: MSTI1 Normal Port3 Configuration - Path Cost Valid values are in the range 0 to 200000000. Setting 0 means Auto path c… |
| 1.3.6.1.4.1.4756.20.440.20.1.556 | ColumneddMSTI1Port3PriorityLocal | read-write | current | EDD Series card MSTI Port Configuration: MSTI1 Normal Port3 Configuration - Priority |
| 1.3.6.1.4.1.4756.20.440.20.1.557 | ColumneddMSTI1Port4PathCostLocal | read-write | current | EDD Series card MSTI Port Configuration: MSTI1 Normal Port4 Configuration - Path Cost Valid values are in the range 0 to 200000000. Setting 0 means Auto path c… |
| 1.3.6.1.4.1.4756.20.440.20.1.558 | ColumneddMSTI1Port4PriorityLocal | read-write | current | EDD Series card MSTI Port Configuration: MSTI1 Normal Port4 Configuration - Priority |
| 1.3.6.1.4.1.4756.20.440.20.1.559 | ColumneddMSTI2AggregatedPathCostLocal | read-write | current | EDD Series card MSTI Port Configuration: MSTI2 Aggregated Ports Configuration - Path Cost Valid values are in the range 0 to 200000000. Setting 0 means Auto pa… |
| 1.3.6.1.4.1.4756.20.440.20.1.560 | ColumneddMSTI2AggregatedPriorityLocal | read-write | current | EDD Series card MSTI Port Configuration: MSTI2 Aggregated Ports Configuration - Priority |
| 1.3.6.1.4.1.4756.20.440.20.1.561 | ColumneddMSTI2Port1PathCostLocal | read-write | current | EDD Series card MSTI Port Configuration: MSTI2 Normal Port1 Configuration - Path Cost Valid values are in the range 0 to 200000000. Setting 0 means Auto path c… |
| 1.3.6.1.4.1.4756.20.440.20.1.562 | ColumneddMSTI2Port1PriorityLocal | read-write | current | EDD Series card MSTI Port Configuration: MSTI2 Normal Port1 Configuration - Priority |
| 1.3.6.1.4.1.4756.20.440.20.1.563 | ColumneddMSTI2Port2PathCostLocal | read-write | current | EDD Series card MSTI Port Configuration: MSTI2 Normal Port2 Configuration - Path Cost Valid values are in the range 0 to 200000000. Setting 0 means Auto path c… |
| 1.3.6.1.4.1.4756.20.440.20.1.564 | ColumneddMSTI2Port2PriorityLocal | read-write | current | EDD Series card MSTI Port Configuration: MSTI2 Normal Port2 Configuration - Priority |
| 1.3.6.1.4.1.4756.20.440.20.1.565 | ColumneddMSTI2Port3PathCostLocal | read-write | current | EDD Series card MSTI Port Configuration: MSTI2 Normal Port3 Configuration - Path Cost Valid values are in the range 0 to 200000000. Setting 0 means Auto path c… |
| 1.3.6.1.4.1.4756.20.440.20.1.566 | ColumneddMSTI2Port3PriorityLocal | read-write | current | EDD Series card MSTI Port Configuration: MSTI2 Normal Port3 Configuration - Priority |
| 1.3.6.1.4.1.4756.20.440.20.1.567 | ColumneddMSTI2Port4PathCostLocal | read-write | current | EDD Series card MSTI Port Configuration: MSTI2 Normal Port4 Configuration - Path Cost Valid values are in the range 0 to 200000000. Setting 0 means Auto path c… |
| 1.3.6.1.4.1.4756.20.440.20.1.568 | ColumneddMSTI2Port4PriorityLocal | read-write | current | EDD Series card MSTI Port Configuration: MSTI2 Normal Port4 Configuration - Priority |
| 1.3.6.1.4.1.4756.20.440.20.1.569 | ColumneddMSTI3AggregatedPathCostLocal | read-write | current | EDD Series card MSTI Port Configuration: MSTI3 Aggregated Ports Configuration - Path Cost Valid values are in the range 0 to 200000000. Setting 0 means Auto pa… |
| 1.3.6.1.4.1.4756.20.440.20.1.570 | ColumneddMSTI3AggregatedPriorityLocal | read-write | current | EDD Series card MSTI Port Configuration: MSTI3 Aggregated Ports Configuration - Priority |
| 1.3.6.1.4.1.4756.20.440.20.1.571 | ColumneddMSTI3Port1PathCostLocal | read-write | current | EDD Series card MSTI Port Configuration: MSTI3 Normal Port1 Configuration - Path Cost Valid values are in the range 0 to 200000000. Setting 0 means Auto path c… |
| 1.3.6.1.4.1.4756.20.440.20.1.572 | ColumneddMSTI3Port1PriorityLocal | read-write | current | EDD Series card MSTI Port Configuration: MSTI3 Normal Port1 Configuration - Priority |
| 1.3.6.1.4.1.4756.20.440.20.1.573 | ColumneddMSTI3Port2PathCostLocal | read-write | current | EDD Series card MSTI Port Configuration: MSTI3 Normal Port2 Configuration - Path Cost Valid values are in the range 0 to 200000000. Setting 0 means Auto path c… |
| 1.3.6.1.4.1.4756.20.440.20.1.574 | ColumneddMSTI3Port2PriorityLocal | read-write | current | EDD Series card MSTI Port Configuration: MSTI3 Normal Port2 Configuration - Priority |
| 1.3.6.1.4.1.4756.20.440.20.1.575 | ColumneddMSTI3Port3PathCostLocal | read-write | current | EDD Series card MSTI Port Configuration: MSTI1 Normal Port3 Configuration - Path Cost Valid values are in the range 0 to 200000000. Setting 0 means Auto path c… |
| 1.3.6.1.4.1.4756.20.440.20.1.576 | ColumneddMSTI3Port3PriorityLocal | read-write | current | EDD Series card MSTI Port Configuration: MSTI3 Normal Port3 Configuration - Priority |
| 1.3.6.1.4.1.4756.20.440.20.1.577 | ColumneddMSTI3Port4PathCostLocal | read-write | current | EDD Series card MSTI Port Configuration: MSTI3 Normal Port4 Configuration - Path Cost Valid values are in the range 0 to 200000000. Setting 0 means Auto path c… |
| 1.3.6.1.4.1.4756.20.440.20.1.578 | ColumneddMSTI3Port4PriorityLocal | read-write | current | EDD Series card MSTI Port Configuration: MSTI3 Normal Port4 Configuration - Priority |
| 1.3.6.1.4.1.4756.20.440.20.1.579 | ColumneddMSTI4AggregatedPathCostLocal | read-write | current | EDD Series card MSTI Port Configuration: MSTI4 Aggregated Ports Configuration - Path Cost Valid values are in the range 0 to 200000000. Setting 0 means Auto pa… |
| 1.3.6.1.4.1.4756.20.440.20.1.580 | ColumneddMSTI4AggregatedPriorityLocal | read-write | current | EDD Series card MSTI Port Configuration: MSTI4 Aggregated Ports Configuration - Priority |
| 1.3.6.1.4.1.4756.20.440.20.1.581 | ColumneddMSTI4Port1PathCostLocal | read-write | current | EDD Series card MSTI Port Configuration: MSTI4 Normal Port1 Configuration - Path Cost Valid values are in the range 0 to 200000000. Setting 0 means Auto path c… |
| 1.3.6.1.4.1.4756.20.440.20.1.582 | ColumneddMSTI4Port1PriorityLocal | read-write | current | EDD Series card MSTI Port Configuration: MSTI4 Normal Port1 Configuration - Priority |
| 1.3.6.1.4.1.4756.20.440.20.1.583 | ColumneddMSTI4Port2PathCostLocal | read-write | current | EDD Series card MSTI Port Configuration: MSTI4 Normal Port2 Configuration - Path Cost Valid values are in the range 0 to 200000000. Setting 0 means Auto path c… |
| 1.3.6.1.4.1.4756.20.440.20.1.584 | ColumneddMSTI4Port2PriorityLocal | read-write | current | EDD Series card MSTI Port Configuration: MSTI4 Normal Port2 Configuration - Priority |
| 1.3.6.1.4.1.4756.20.440.20.1.585 | ColumneddMSTI4Port3PathCostLocal | read-write | current | EDD Series card MSTI Port Configuration: MSTI1 Normal Port3 Configuration - Path Cost Valid values are in the range 0 to 200000000. Setting 0 means Auto path c… |
| 1.3.6.1.4.1.4756.20.440.20.1.586 | ColumneddMSTI4Port3PriorityLocal | read-write | current | EDD Series card MSTI Port Configuration: MSTI4 Normal Port3 Configuration - Priority |
| 1.3.6.1.4.1.4756.20.440.20.1.587 | ColumneddMSTI4Port4PathCostLocal | read-write | current | EDD Series card MSTI Port Configuration: MSTI4 Normal Port4 Configuration - Path Cost Valid values are in the range 0 to 200000000. Setting 0 means Auto path c… |
| 1.3.6.1.4.1.4756.20.440.20.1.588 | ColumneddMSTI4Port4PriorityLocal | read-write | current | EDD Series card MSTI Port Configuration: MSTI4 Normal Port4 Configuration - Priority |
| 1.3.6.1.4.1.4756.20.440.20.1.589 | ColumneddMSTI5AggregatedPathCostLocal | read-write | current | EDD Series card MSTI Port Configuration: MSTI5 Aggregated Ports Configuration - Path Cost Valid values are in the range 0 to 200000000. Setting 0 means Auto pa… |
| 1.3.6.1.4.1.4756.20.440.20.1.590 | ColumneddMSTI5AggregatedPriorityLocal | read-write | current | EDD Series card MSTI Port Configuration: MSTI5 Aggregated Ports Configuration - Priority |
| 1.3.6.1.4.1.4756.20.440.20.1.591 | ColumneddMSTI5Port1PathCostLocal | read-write | current | EDD Series card MSTI Port Configuration: MSTI5 Normal Port1 Configuration - Path Cost Valid values are in the range 0 to 200000000. Setting 0 means Auto path c… |
| 1.3.6.1.4.1.4756.20.440.20.1.592 | ColumneddMSTI5Port1PriorityLocal | read-write | current | EDD Series card MSTI Port Configuration: MSTI5 Normal Port1 Configuration - Priority |
| 1.3.6.1.4.1.4756.20.440.20.1.593 | ColumneddMSTI5Port2PathCostLocal | read-write | current | EDD Series card MSTI Port Configuration: MSTI5 Normal Port2 Configuration - Path Cost Valid values are in the range 0 to 200000000. Setting 0 means Auto path c… |
| 1.3.6.1.4.1.4756.20.440.20.1.594 | ColumneddMSTI5Port2PriorityLocal | read-write | current | EDD Series card MSTI Port Configuration: MSTI5 Normal Port2 Configuration - Priority |
| 1.3.6.1.4.1.4756.20.440.20.1.595 | ColumneddMSTI5Port3PathCostLocal | read-write | current | EDD Series card MSTI Port Configuration: MSTI5 Normal Port3 Configuration - Path Cost Valid values are in the range 0 to 200000000. Setting 0 means Auto path c… |
| 1.3.6.1.4.1.4756.20.440.20.1.596 | ColumneddMSTI5Port3PriorityLocal | read-write | current | EDD Series card MSTI Port Configuration: MSTI5 Normal Port3 Configuration - Priority |
| 1.3.6.1.4.1.4756.20.440.20.1.597 | ColumneddMSTI5Port4PathCostLocal | read-write | current | EDD Series card MSTI Port Configuration: MSTI5 Normal Port4 Configuration - Path Cost Valid values are in the range 0 to 200000000. Setting 0 means Auto path c… |
| 1.3.6.1.4.1.4756.20.440.20.1.598 | ColumneddMSTI5Port4PriorityLocal | read-write | current | EDD Series card MSTI Port Configuration: MSTI5 Normal Port4 Configuration - Priority |
| 1.3.6.1.4.1.4756.20.440.20.1.599 | ColumneddMSTI6AggregatedPathCostLocal | read-write | current | EDD Series card MSTI Port Configuration: MSTI6 Aggregated Ports Configuration - Path Cost Valid values are in the range 0 to 200000000. Setting 0 means Auto pa… |
| 1.3.6.1.4.1.4756.20.440.20.1.600 | ColumneddMSTI6AggregatedPriorityLocal | read-write | current | EDD Series card MSTI Port Configuration: MSTI6 Aggregated Ports Configuration - Priority |
| 1.3.6.1.4.1.4756.20.440.20.1.601 | ColumneddMSTI6Port1PathCostLocal | read-write | current | EDD Series card MSTI Port Configuration: MSTI6 Normal Port1 Configuration - Path Cost Valid values are in the range 0 to 200000000. Setting 0 means Auto path c… |
| 1.3.6.1.4.1.4756.20.440.20.1.602 | ColumneddMSTI6Port1PriorityLocal | read-write | current | EDD Series card MSTI Port Configuration: MSTI6 Normal Port1 Configuration - Priority |
| 1.3.6.1.4.1.4756.20.440.20.1.603 | ColumneddMSTI6Port2PathCostLocal | read-write | current | EDD Series card MSTI Port Configuration: MSTI6 Normal Port2 Configuration - Path Cost Valid values are in the range 0 to 200000000. Setting 0 means Auto path c… |
| 1.3.6.1.4.1.4756.20.440.20.1.604 | ColumneddMSTI6Port2PriorityLocal | read-write | current | EDD Series card MSTI Port Configuration: MSTI6 Normal Port2 Configuration - Priority |
| 1.3.6.1.4.1.4756.20.440.20.1.605 | ColumneddMSTI6Port3PathCostLocal | read-write | current | EDD Series card MSTI Port Configuration: MSTI6 Normal Port3 Configuration - Path Cost Valid values are in the range 0 to 200000000. Setting 0 means Auto path c… |
| 1.3.6.1.4.1.4756.20.440.20.1.606 | ColumneddMSTI6Port3PriorityLocal | read-write | current | EDD Series card MSTI Port Configuration: MSTI6 Normal Port3 Configuration - Priority |
| 1.3.6.1.4.1.4756.20.440.20.1.607 | ColumneddMSTI6Port4PathCostLocal | read-write | current | EDD Series card MSTI Port Configuration: MSTI6 Normal Port4 Configuration - Path Cost Valid values are in the range 0 to 200000000. Setting 0 means Auto path c… |
| 1.3.6.1.4.1.4756.20.440.20.1.608 | ColumneddMSTI6Port4PriorityLocal | read-write | current | EDD Series card MSTI Port Configuration: MSTI6 Normal Port4 Configuration - Priority |
| 1.3.6.1.4.1.4756.20.440.20.1.609 | ColumneddMSTI7AggregatedPathCostLocal | read-write | current | EDD Series card MSTI Port Configuration: MSTI7 Aggregated Ports Configuration - Path Cost Valid values are in the range 0 to 200000000. Setting 0 means Auto pa… |
| 1.3.6.1.4.1.4756.20.440.20.1.610 | ColumneddMSTI7AggregatedPriorityLocal | read-write | current | EDD Series card MSTI Port Configuration: MSTI7 Aggregated Ports Configuration - Priority |
| 1.3.6.1.4.1.4756.20.440.20.1.611 | ColumneddMSTI7Port1PathCostLocal | read-write | current | EDD Series card MSTI Port Configuration: MSTI1 Normal Port1 Configuration - Path Cost Valid values are in the range 0 to 200000000. Setting 0 means Auto path c… |
| 1.3.6.1.4.1.4756.20.440.20.1.612 | ColumneddMSTI7Port1PriorityLocal | read-write | current | EDD Series card MSTI Port Configuration: MSTI1 Normal Port7 Configuration - Priority |
| 1.3.6.1.4.1.4756.20.440.20.1.613 | ColumneddMSTI7Port2PathCostLocal | read-write | current | EDD Series card MSTI Port Configuration: MSTI7 Normal Port2 Configuration - Path Cost Valid values are in the range 0 to 200000000. Setting 0 means Auto path c… |
| 1.3.6.1.4.1.4756.20.440.20.1.614 | ColumneddMSTI7Port2PriorityLocal | read-write | current | EDD Series card MSTI Port Configuration: MSTI7 Normal Port2 Configuration - Priority |
| 1.3.6.1.4.1.4756.20.440.20.1.615 | ColumneddMSTI7Port3PathCostLocal | read-write | current | EDD Series card MSTI Port Configuration: MSTI7 Normal Port3 Configuration - Path Cost Valid values are in the range 0 to 200000000. Setting 0 means Auto path c… |
| 1.3.6.1.4.1.4756.20.440.20.1.616 | ColumneddMSTI7Port3PriorityLocal | read-write | current | EDD Series card MSTI Port Configuration: MSTI7 Normal Port3 Configuration - Priority |
| 1.3.6.1.4.1.4756.20.440.20.1.617 | ColumneddMSTI7Port4PathCostLocal | read-write | current | EDD Series card MSTI Port Configuration: MSTI7 Normal Port4 Configuration - Path Cost Valid values are in the range 0 to 200000000. Setting 0 means Auto path c… |
| 1.3.6.1.4.1.4756.20.440.20.1.618 | ColumneddMSTI7Port4PriorityLocal | read-write | current | EDD Series card MSTI Port Configuration: MSTI7 Normal Port4 Configuration - Priority |
| 1.3.6.1.4.1.4756.20.440.20.1.619 | ColumneddCISTBridgeIDLocal | read-only | current | EDD Series card STP Bridges status: CIST - Bridge ID |
| 1.3.6.1.4.1.4756.20.440.20.1.620 | ColumneddCISTRootIDLocal | read-only | current | EDD Series card STP Bridges status: CIST - Root ID |
| 1.3.6.1.4.1.4756.20.440.20.1.621 | ColumneddCISTRootPortLocal | read-only | current | EDD Series card STP Bridges status: CIST - Root Port |
| 1.3.6.1.4.1.4756.20.440.20.1.622 | ColumneddCISTRootCostLocal | read-only | current | EDD Series card STP Bridges status: CIST - Root Cost |
| 1.3.6.1.4.1.4756.20.440.20.1.623 | ColumneddCISTTopologyFlagLocal | read-only | current | EDD Series card STP Bridges status: CIST - Topology Flag |
| 1.3.6.1.4.1.4756.20.440.20.1.624 | ColumneddCISTTopologyChangeLastLocal | read-only | current | EDD Series card STP Bridges status: CIST - Topology Change Last |
| 1.3.6.1.4.1.4756.20.440.20.1.625 | ColumneddMSTI1BridgeIDLocal | read-only | current | EDD Series card STP Bridges status: MSTI1 - Bridge ID |
| 1.3.6.1.4.1.4756.20.440.20.1.626 | ColumneddMSTI1RootIDLocal | read-only | current | EDD Series card STP Bridges status: MSTI1 - Root ID |
| 1.3.6.1.4.1.4756.20.440.20.1.627 | ColumneddMSTI1RootPortLocal | read-only | current | EDD Series card STP Bridges status: MSTI1 - Root ID |
| 1.3.6.1.4.1.4756.20.440.20.1.628 | ColumneddMSTI1RootCostLocal | read-only | current | EDD Series card STP Bridges status: MSTI1 - Root Cost |
| 1.3.6.1.4.1.4756.20.440.20.1.629 | ColumneddMSTI1TopologyFlagLocal | read-only | current | EDD Series card STP Bridges status: MSTI1 - Topology Flag |
| 1.3.6.1.4.1.4756.20.440.20.1.630 | ColumneddMSTI1TopologyChangeLastLocal | read-only | current | EDD Series card STP Bridges status: MSTI1 - Topology Change Last |
| 1.3.6.1.4.1.4756.20.440.20.1.631 | ColumneddMSTI2BridgeIDLocal | read-only | current | EDD Series card STP Bridges status: MSTI2 - Bridge ID |
| 1.3.6.1.4.1.4756.20.440.20.1.632 | ColumneddMSTI2RootIDLocal | read-only | current | EDD Series card STP Bridges status: MSTI2 - Root ID |
| 1.3.6.1.4.1.4756.20.440.20.1.633 | ColumneddMSTI2RootPortLocal | read-only | current | EDD Series card STP Bridges status: MSTI2 - Root ID |
| 1.3.6.1.4.1.4756.20.440.20.1.634 | ColumneddMSTI2RootCostLocal | read-only | current | EDD Series card STP Bridges status: MSTI2 - Root Cost |
| 1.3.6.1.4.1.4756.20.440.20.1.635 | ColumneddMSTI2TopologyFlagLocal | read-only | current | EDD Series card STP Bridges status: MSTI2 - Topology Flag |
| 1.3.6.1.4.1.4756.20.440.20.1.636 | ColumneddMSTI2TopologyChangeLastLocal | read-only | current | EDD Series card STP Bridges status: MSTI2 - Topology Change Last |
| 1.3.6.1.4.1.4756.20.440.20.1.637 | ColumneddMSTI3BridgeIDLocal | read-only | current | EDD Series card STP Bridges status: MSTI3 - Bridge ID |
| 1.3.6.1.4.1.4756.20.440.20.1.638 | ColumneddMSTI3RootIDLocal | read-only | current | EDD Series card STP Bridges status: MSTI3 - Root ID |
| 1.3.6.1.4.1.4756.20.440.20.1.639 | ColumneddMSTI3RootPortLocal | read-only | current | EDD Series card STP Bridges status: MSTI3 - Root ID |
| 1.3.6.1.4.1.4756.20.440.20.1.640 | ColumneddMSTI3RootCostLocal | read-only | current | EDD Series card STP Bridges status: MSTI3 - Root Cost |
| 1.3.6.1.4.1.4756.20.440.20.1.641 | ColumneddMSTI3TopologyFlagLocal | read-only | current | EDD Series card STP Bridges status: MSTI3 - Topology Flag |
| 1.3.6.1.4.1.4756.20.440.20.1.642 | ColumneddMSTI3TopologyChangeLastLocal | read-only | current | EDD Series card STP Bridges status: MSTI3 - Topology Change Last |
| 1.3.6.1.4.1.4756.20.440.20.1.643 | ColumneddMSTI4BridgeIDLocal | read-only | current | EDD Series card STP Bridges status: MSTI4 - Bridge ID |
| 1.3.6.1.4.1.4756.20.440.20.1.644 | ColumneddMSTI4RootIDLocal | read-only | current | EDD Series card STP Bridges status: MSTI4 - Root ID |
| 1.3.6.1.4.1.4756.20.440.20.1.645 | ColumneddMSTI4RootPortLocal | read-only | current | EDD Series card STP Bridges status: MSTI4 - Root ID |
| 1.3.6.1.4.1.4756.20.440.20.1.646 | ColumneddMSTI4RootCostLocal | read-only | current | EDD Series card STP Bridges status: MSTI4 - Root Cost |
| 1.3.6.1.4.1.4756.20.440.20.1.647 | ColumneddMSTI4TopologyFlagLocal | read-only | current | EDD Series card STP Bridges status: MSTI4 - Topology Flag |
| 1.3.6.1.4.1.4756.20.440.20.1.648 | ColumneddMSTI4TopologyChangeLastLocal | read-only | current | EDD Series card STP Bridges status: MSTI4 - Topology Change Last |
| 1.3.6.1.4.1.4756.20.440.20.1.649 | ColumneddMSTI5BridgeIDLocal | read-only | current | EDD Series card STP Bridges status: MSTI5 - Bridge ID |
| 1.3.6.1.4.1.4756.20.440.20.1.650 | ColumneddMSTI5RootIDLocal | read-only | current | EDD Series card STP Bridges status: MSTI5 - Root ID |
| 1.3.6.1.4.1.4756.20.440.20.1.651 | ColumneddMSTI5RootPortLocal | read-only | current | EDD Series card STP Bridges status: MSTI5 - Root ID |
| 1.3.6.1.4.1.4756.20.440.20.1.652 | ColumneddMSTI5RootCostLocal | read-only | current | EDD Series card STP Bridges status: MSTI5 - Root Cost |
| 1.3.6.1.4.1.4756.20.440.20.1.653 | ColumneddMSTI5TopologyFlagLocal | read-only | current | EDD Series card STP Bridges status: MSTI5 - Topology Flag |
| 1.3.6.1.4.1.4756.20.440.20.1.654 | ColumneddMSTI5TopologyChangeLastLocal | read-only | current | EDD Series card STP Bridges status: MSTI5 - Topology Change Last |
| 1.3.6.1.4.1.4756.20.440.20.1.655 | ColumneddMSTI6BridgeIDLocal | read-only | current | EDD Series card STP Bridges status: MSTI6 - Bridge ID |
| 1.3.6.1.4.1.4756.20.440.20.1.656 | ColumneddMSTI6RootIDLocal | read-only | current | EDD Series card STP Bridges status: MSTI6 - Root ID |
| 1.3.6.1.4.1.4756.20.440.20.1.657 | ColumneddMSTI6RootPortLocal | read-only | current | EDD Series card STP Bridges status: MSTI6 - Root ID |
| 1.3.6.1.4.1.4756.20.440.20.1.658 | ColumneddMSTI6RootCostLocal | read-only | current | EDD Series card STP Bridges status: MSTI6 - Root Cost |
| 1.3.6.1.4.1.4756.20.440.20.1.659 | ColumneddMSTI6TopologyFlagLocal | read-only | current | EDD Series card STP Bridges status: MSTI6 - Topology Flag |
| 1.3.6.1.4.1.4756.20.440.20.1.660 | ColumneddMSTI6TopologyChangeLastLocal | read-only | current | EDD Series card STP Bridges status: MSTI6 - Topology Change Last |
| 1.3.6.1.4.1.4756.20.440.20.1.661 | ColumneddMSTI7BridgeIDLocal | read-only | current | EDD Series card STP Bridges status: MSTI7 - Bridge ID |
| 1.3.6.1.4.1.4756.20.440.20.1.662 | ColumneddMSTI7RootIDLocal | read-only | current | EDD Series card STP Bridges status: MSTI7 - Root ID |
| 1.3.6.1.4.1.4756.20.440.20.1.663 | ColumneddMSTI7RootPortLocal | read-only | current | EDD Series card STP Bridges status: MSTI7 - Root ID |
| 1.3.6.1.4.1.4756.20.440.20.1.664 | ColumneddMSTI7RootCostLocal | read-only | current | EDD Series card STP Bridges status: MSTI7 - Root Cost |
| 1.3.6.1.4.1.4756.20.440.20.1.665 | ColumneddMSTI7TopologyFlagLocal | read-only | current | EDD Series card STP Bridges status: MSTI7 - Topology Flag |
| 1.3.6.1.4.1.4756.20.440.20.1.666 | ColumneddMSTI7TopologyChangeLastLocal | read-only | current | EDD Series card STP Bridges status: MSTI7 - Topology Change Last |
| 1.3.6.1.4.1.4756.20.440.20.1.667 | ColumneddSTPPortStatusInst1PortLocal | read-only | current | EDD Series card STP Port status: Instance1 - Port |
| 1.3.6.1.4.1.4756.20.440.20.1.668 | ColumneddSTPPortStatusInst1CISTRoleLocal | read-only | current | EDD Series card STP Port status: Instance1 - CIST Role |
| 1.3.6.1.4.1.4756.20.440.20.1.669 | ColumneddSTPPortStatusInst1CISTStateLocal | read-only | current | EDD Series card STP Port status: Instance1 - CIST State |
| 1.3.6.1.4.1.4756.20.440.20.1.670 | ColumneddSTPPortStatusInst1UptimeLocal | read-only | current | EDD Series card STP Port status: Instance1 -Uptime |
| 1.3.6.1.4.1.4756.20.440.20.1.671 | ColumneddSTPPortStatusInst2PortLocal | read-only | current | EDD Series card STP Port status: Instance2 - Port |
| 1.3.6.1.4.1.4756.20.440.20.1.672 | ColumneddSTPPortStatusInst2CISTRoleLocal | read-only | current | EDD Series card STP Port status: Instance2 - CIST Role |
| 1.3.6.1.4.1.4756.20.440.20.1.673 | ColumneddSTPPortStatusInst2CISTStateLocal | read-only | current | EDD Series card STP Port status: Instance2 - CIST State |
| 1.3.6.1.4.1.4756.20.440.20.1.674 | ColumneddSTPPortStatusInst2UptimeLocal | read-only | current | EDD Series card STP Port status: Instance2 -Uptime |
| 1.3.6.1.4.1.4756.20.440.20.1.675 | ColumneddSTPPortStatusInst3PortLocal | read-only | current | EDD Series card STP Port status: Instance3 - Port |
| 1.3.6.1.4.1.4756.20.440.20.1.676 | ColumneddSTPPortStatusInst3CISTRoleLocal | read-only | current | EDD Series card STP Port status: Instance3 - CIST Role |
| 1.3.6.1.4.1.4756.20.440.20.1.677 | ColumneddSTPPortStatusInst3CISTStateLocal | read-only | current | EDD Series card STP Port status: Instance3 - CIST State |
| 1.3.6.1.4.1.4756.20.440.20.1.678 | ColumneddSTPPortStatusInst3UptimeLocal | read-only | current | EDD Series card STP Port status: Instance3 -Uptime |
| 1.3.6.1.4.1.4756.20.440.20.1.679 | ColumneddSTPPortStatusInst4PortLocal | read-only | current | EDD Series card STP Port status: Instance4 - Port |
| 1.3.6.1.4.1.4756.20.440.20.1.680 | ColumneddSTPPortStatusInst4CISTRoleLocal | read-only | current | EDD Series card STP Port status: Instance4 - CIST Role |
| 1.3.6.1.4.1.4756.20.440.20.1.681 | ColumneddSTPPortStatusInst4CISTStateLocal | read-only | current | EDD Series card STP Port status: Instance4 - CIST State |
| 1.3.6.1.4.1.4756.20.440.20.1.682 | ColumneddSTPPortStatusInst4UptimeLocal | read-only | current | EDD Series card STP Port status: Instance4 -Uptime |
| 1.3.6.1.4.1.4756.20.440.20.1.683 | ColumneddSTPStatisticsPort1TxMSTPLocal | read-only | current | EDD Series card STP Port Statistics: Port1 -Transmitted MSTP |
| 1.3.6.1.4.1.4756.20.440.20.1.684 | ColumneddSTPStatisticsPort1TxRSTPLocal | read-only | current | EDD Series card STP Port Statistics: Port1 -Transmitted RSTP |
| 1.3.6.1.4.1.4756.20.440.20.1.685 | ColumneddSTPStatisticsPort1TxSTPLocal | read-only | current | EDD Series card STP Port Statistics: Port1 -Transmitted RSTP |
| 1.3.6.1.4.1.4756.20.440.20.1.686 | ColumneddSTPStatisticsPort1TxTCNLocal | read-only | current | EDD Series card STP Port Statistics: Port1 -Transmitted RSTP |
| 1.3.6.1.4.1.4756.20.440.20.1.687 | ColumneddSTPStatisticsPort1RxMSTPLocal | read-only | current | EDD Series card STP Port Statistics: Port1 -Received MSTP |
| 1.3.6.1.4.1.4756.20.440.20.1.688 | ColumneddSTPStatisticsPort1RxRSTPLocal | read-only | current | EDD Series card STP Port Statistics: Port1 -Received RSTP |
| 1.3.6.1.4.1.4756.20.440.20.1.689 | ColumneddSTPStatisticsPort1RxSTPLocal | read-only | current | EDD Series card STP Port Statistics: Port1 -Received RSTP |
| 1.3.6.1.4.1.4756.20.440.20.1.690 | ColumneddSTPStatisticsPort1RxTCNLocal | read-only | current | EDD Series card STP Port Statistics: Port1 -Received RSTP |
| 1.3.6.1.4.1.4756.20.440.20.1.691 | ColumneddSTPStatisticsPort1DiscardUnknowLocal | read-only | current | EDD Series card STP Port Statistics: Port1 -Discarded Unknown |
| 1.3.6.1.4.1.4756.20.440.20.1.692 | ColumneddSTPStatisticsPort1DiscardIllegalLocal | read-only | current | EDD Series card STP Port Statistics: Port1 -Discarded Illegal |
| 1.3.6.1.4.1.4756.20.440.20.1.693 | ColumneddSTPStatisticsPort2TxMSTPLocal | read-only | current | EDD Series card STP Port Statistics: Port2 -Transmitted MSTP |
| 1.3.6.1.4.1.4756.20.440.20.1.694 | ColumneddSTPStatisticsPort2TxRSTPLocal | read-only | current | EDD Series card STP Port Statistics: Port2 -Transmitted RSTP |
| 1.3.6.1.4.1.4756.20.440.20.1.695 | ColumneddSTPStatisticsPort2TxSTPLocal | read-only | current | EDD Series card STP Port Statistics: Port2 -Transmitted RSTP |
| 1.3.6.1.4.1.4756.20.440.20.1.696 | ColumneddSTPStatisticsPort2TxTCNLocal | read-only | current | EDD Series card STP Port Statistics: Port2 -Transmitted RSTP |
| 1.3.6.1.4.1.4756.20.440.20.1.697 | ColumneddSTPStatisticsPort2RxMSTPLocal | read-only | current | EDD Series card STP Port Statistics: Port2 -Received MSTP |
| 1.3.6.1.4.1.4756.20.440.20.1.698 | ColumneddSTPStatisticsPort2RxRSTPLocal | read-only | current | EDD Series card STP Port Statistics: Port1 -Received RSTP |
| 1.3.6.1.4.1.4756.20.440.20.1.699 | ColumneddSTPStatisticsPort2RxSTPLocal | read-only | current | EDD Series card STP Port Statistics: Port2 -Received RSTP |
| 1.3.6.1.4.1.4756.20.440.20.1.700 | ColumneddSTPStatisticsPort2RxTCNLocal | read-only | current | EDD Series card STP Port Statistics: Port2 -Received RSTP |
| 1.3.6.1.4.1.4756.20.440.20.1.701 | ColumneddSTPStatisticsPort2DiscardUnknowLocal | read-only | current | EDD Series card STP Port Statistics: Port2 -Discarded Unknown |
| 1.3.6.1.4.1.4756.20.440.20.1.702 | ColumneddSTPStatisticsPort2DiscardIllegalLocal | read-only | current | EDD Series card STP Port Statistics: Port2 -Discarded Illegal |
| 1.3.6.1.4.1.4756.20.440.20.1.703 | ColumneddSTPStatisticsPort3TxMSTPLocal | read-only | current | EDD Series card STP Port Statistics: Port3 -Transmitted MSTP |
| 1.3.6.1.4.1.4756.20.440.20.1.704 | ColumneddSTPStatisticsPort3TxRSTPLocal | read-only | current | EDD Series card STP Port Statistics: Port3 -Transmitted RSTP |
| 1.3.6.1.4.1.4756.20.440.20.1.705 | ColumneddSTPStatisticsPort3TxSTPLocal | read-only | current | EDD Series card STP Port Statistics: Port3 -Transmitted RSTP |
| 1.3.6.1.4.1.4756.20.440.20.1.706 | ColumneddSTPStatisticsPort3TxTCNLocal | read-only | current | EDD Series card STP Port Statistics: Port3 -Transmitted RSTP |
| 1.3.6.1.4.1.4756.20.440.20.1.707 | ColumneddSTPStatisticsPort3RxMSTPLocal | read-only | current | EDD Series card STP Port Statistics: Port3 -Received MSTP |
| 1.3.6.1.4.1.4756.20.440.20.1.708 | ColumneddSTPStatisticsPort3RxRSTPLocal | read-only | current | EDD Series card STP Port Statistics: Port3 -Received RSTP |
| 1.3.6.1.4.1.4756.20.440.20.1.709 | ColumneddSTPStatisticsPort3RxSTPLocal | read-only | current | EDD Series card STP Port Statistics: Port3 -Received RSTP |
| 1.3.6.1.4.1.4756.20.440.20.1.710 | ColumneddSTPStatisticsPort3RxTCNLocal | read-only | current | EDD Series card STP Port Statistics: Port3 -Received RSTP |
| 1.3.6.1.4.1.4756.20.440.20.1.711 | ColumneddSTPStatisticsPort3DiscardUnknowLocal | read-only | current | EDD Series card STP Port Statistics: Port3 -Discarded Unknown |
| 1.3.6.1.4.1.4756.20.440.20.1.712 | ColumneddSTPStatisticsPort3DiscardIllegalLocal | read-only | current | EDD Series card STP Port Statistics: Port3 -Discarded Illegal |
| 1.3.6.1.4.1.4756.20.440.20.1.713 | ColumneddSTPStatisticsPort4TxMSTPLocal | read-only | current | EDD Series card STP Port Statistics: Port4 -Transmitted MSTP |
| 1.3.6.1.4.1.4756.20.440.20.1.714 | ColumneddSTPStatisticsPort4TxRSTPLocal | read-only | current | EDD Series card STP Port Statistics: Port4 -Transmitted RSTP |
| 1.3.6.1.4.1.4756.20.440.20.1.715 | ColumneddSTPStatisticsPort4TxSTPLocal | read-only | current | EDD Series card STP Port Statistics: Port4 -Transmitted RSTP |
| 1.3.6.1.4.1.4756.20.440.20.1.716 | ColumneddSTPStatisticsPort4TxTCNLocal | read-only | current | EDD Series card STP Port Statistics: Port4 -Transmitted RSTP |
| 1.3.6.1.4.1.4756.20.440.20.1.717 | ColumneddSTPStatisticsPort4RxMSTPLocal | read-only | current | EDD Series card STP Port Statistics: Port4 -Received MSTP |
| 1.3.6.1.4.1.4756.20.440.20.1.718 | ColumneddSTPStatisticsPort4RxRSTPLocal | read-only | current | EDD Series card STP Port Statistics: Port4 -Received RSTP |
| 1.3.6.1.4.1.4756.20.440.20.1.719 | ColumneddSTPStatisticsPort4RxSTPLocal | read-only | current | EDD Series card STP Port Statistics: Port4 -Received RSTP |
| 1.3.6.1.4.1.4756.20.440.20.1.720 | ColumneddSTPStatisticsPort4RxTCNLocal | read-only | current | EDD Series card STP Port Statistics: Port4 -Received RSTP |
| 1.3.6.1.4.1.4756.20.440.20.1.721 | ColumneddSTPStatisticsPort4DiscardUnknowLocal | read-only | current | EDD Series card STP Port Statistics: Port4 -Discarded Unknown |
| 1.3.6.1.4.1.4756.20.440.20.1.722 | ColumneddSTPStatisticsPort4DiscardIllegalLocal | read-only | current | EDD Series card STP Port Statistics: Port4 -Discarded Illegal |
| 1.3.6.1.4.1.4756.20.440.20.1.723 | ColumneddSTPStatisticsPortClearCounterLocal | read-write | current | EDD Series card STP Port Statistics: Clear Counters 0: OFff 1: Action |
| 1.3.6.1.4.1.4756.20.440.20.1.724 | ColumneddAllowedAccessVLANsLocal | read-write | current | EDD Series card Global VLAN Configuration: Allowed Access VLANs By default, only VLAN 1 is enabled. More VLANs may be created by using a list syntax where the … |
| 1.3.6.1.4.1.4756.20.440.20.1.725 | ColumneddVlanEthertypeLocal | read-write | current | EDD Series card Global VLAN Configuration: Ethertype for Custom S-ports The format of 'Ethernet Type' is restricted to 0x600-0xFFFF |
| 1.3.6.1.4.1.4756.20.440.20.1.726 | ColumneddPort1VlanModeLocal | read-write | current | EDD Series card Port VLAN Configuration : Port1 - Mode 0: Access 1: Trunk 2: Hybrid |
| 1.3.6.1.4.1.4756.20.440.20.1.727 | ColumneddPort1VlanIDLocal | read-write | current | EDD Series card Port VLAN Configuration : Port1 - VLAN ID |
| 1.3.6.1.4.1.4756.20.440.20.1.728 | ColumneddPort1VlanTypeLocal | read-write | current | EDD Series card Port VLAN Configuration : Port1 - VLAN Type 0: Unaware 1: C-port 2: S-port 3: S-custom-port |
| 1.3.6.1.4.1.4756.20.440.20.1.729 | ColumneddPort1VlanIngressFilteringLocal | read-write | current | EDD Series card Port VLAN Configuration : Port1 - Ingress Filtering 0: Off 1: On |
| 1.3.6.1.4.1.4756.20.440.20.1.730 | ColumneddPort1VlanIngressAcceptanceLocal | read-write | current | EDD Series card Port VLAN Configuration : Port1 - Ingress Acceptance 0: Tagged and untagged 1: Tagged only 2: Untagged only |
| 1.3.6.1.4.1.4756.20.440.20.1.731 | ColumneddPort1VlanEgressTaggingLocal | read-write | current | EDD Series card Port VLAN Configuration : Port1 - Egress Tagging 0: Untag port vlan 1: Tag all 2: Untag all |
| 1.3.6.1.4.1.4756.20.440.20.1.732 | ColumneddPort1AllowedVLANSLocal | read-write | current | EDD Series card Global VLAN Configuration: Port1 - Allowed VLANs By default, only VLAN 1 is enabled. More VLANs may be created by using a list syntax where the… |
| 1.3.6.1.4.1.4756.20.440.20.1.733 | ColumneddPort1ForbiddenVLANSLocal | read-write | current | EDD Series card Global VLAN Configuration: Port1 - Forbidden VLANs By default, the field is left blank, which means that the port may become a member of all po… |
| 1.3.6.1.4.1.4756.20.440.20.1.734 | ColumneddPort2VlanModeLocal | read-write | current | EDD Series card Port VLAN Configuration : Port2 - Mode 0: Access 1: Trunk 2: Hybrid |
| 1.3.6.1.4.1.4756.20.440.20.1.735 | ColumneddPort2VlanIDLocal | read-write | current | EDD Series card Port VLAN Configuration : Port2 - VLAN ID |
| 1.3.6.1.4.1.4756.20.440.20.1.736 | ColumneddPort2VlanTypeLocal | read-write | current | EDD Series card Port VLAN Configuration : Port2 - VLAN Type 0: Unaware 1: C-port 2: S-port 3: S-custom-port |
| 1.3.6.1.4.1.4756.20.440.20.1.737 | ColumneddPort2VlanIngressFilteringLocal | read-write | current | EDD Series card Port VLAN Configuration : Port2 - Ingress Filtering 0: Off 1: On |
| 1.3.6.1.4.1.4756.20.440.20.1.738 | ColumneddPort2VlanIngressAcceptanceLocal | read-write | current | EDD Series card Port VLAN Configuration : Por2 - Ingress Acceptance 0: Tagged and untagged 1: Tagged only 2: Untagged only |
| 1.3.6.1.4.1.4756.20.440.20.1.739 | ColumneddPort2VlanEgressTaggingLocal | read-write | current | EDD Series card Port VLAN Configuration : Port2 - Egress Tagging 0: Untag port vlan 1: Tag all 2: Untag all |
| 1.3.6.1.4.1.4756.20.440.20.1.740 | ColumneddPort2AllowedVLANSLocal | read-write | current | EDD Series card Global VLAN Configuration: Port2 - Allowed VLANs By default, only VLAN 1 is enabled. More VLANs may be created by using a list syntax where the… |
| 1.3.6.1.4.1.4756.20.440.20.1.741 | ColumneddPort2ForbiddenVLANSLocal | read-write | current | EDD Series card Global VLAN Configuration: Port2 - Forbidden VLANs By default, the field is left blank, which means that the port may become a member of all po… |
| 1.3.6.1.4.1.4756.20.440.20.1.742 | ColumneddPort3VlanModeLocal | read-write | current | EDD Series card Port VLAN Configuration : Port3 - Mode 0: Access 1: Trunk 2: Hybrid |
| 1.3.6.1.4.1.4756.20.440.20.1.743 | ColumneddPort3VlanIDLocal | read-write | current | EDD Series card Port VLAN Configuration : Port3 - VLAN ID |
| 1.3.6.1.4.1.4756.20.440.20.1.744 | ColumneddPort3VlanTypeLocal | read-write | current | EDD Series card Port VLAN Configuration : Port3 - VLAN Type 0: Unaware 1: C-port 2: S-port 3: S-custom-port |
| 1.3.6.1.4.1.4756.20.440.20.1.745 | ColumneddPort3VlanIngressFilteringLocal | read-write | current | EDD Series card Port VLAN Configuration : Port3 - Ingress Filtering 0: Off 1: On |
| 1.3.6.1.4.1.4756.20.440.20.1.746 | ColumneddPort3VlanIngressAcceptanceLocal | read-write | current | EDD Series card Port VLAN Configuration : Port3 - Ingress Acceptance 0: Tagged and untagged 1: Tagged only 2: Untagged only |
| 1.3.6.1.4.1.4756.20.440.20.1.747 | ColumneddPort3VlanEgressTaggingLocal | read-write | current | EDD Series card Port VLAN Configuration : Port3 - Egress Tagging 0: Untag port vlan 1: Tag all 2: Untag all |
| 1.3.6.1.4.1.4756.20.440.20.1.748 | ColumneddPort3AllowedVLANSLocal | read-write | current | EDD Series card Global VLAN Configuration: Port3 - Allowed VLANs By default, only VLAN 1 is enabled. More VLANs may be created by using a list syntax where the… |
| 1.3.6.1.4.1.4756.20.440.20.1.749 | ColumneddPort3ForbiddenVLANSLocal | read-write | current | EDD Series card Global VLAN Configuration: Port3 - Forbidden VLANs By default, the field is left blank, which means that the port may become a member of all po… |
| 1.3.6.1.4.1.4756.20.440.20.1.750 | ColumneddPort4VlanModeLocal | read-write | current | EDD Series card Port VLAN Configuration : Port4 - Mode 0: Access 1: Trunk 2: Hybrid |
| 1.3.6.1.4.1.4756.20.440.20.1.751 | ColumneddPort4VlanIDLocal | read-write | current | EDD Series card Port VLAN Configuration : Port4 - VLAN ID |
| 1.3.6.1.4.1.4756.20.440.20.1.752 | ColumneddPort4VlanTypeLocal | read-write | current | EDD Series card Port VLAN Configuration : Port4 - VLAN Type 0: Unaware 1: C-port 2: S-port 3: S-custom-port |
| 1.3.6.1.4.1.4756.20.440.20.1.753 | ColumneddPort4VlanIngressFilteringLocal | read-write | current | EDD Series card Port VLAN Configuration : Port4 - Ingress Filtering 0: Off 1: On |
| 1.3.6.1.4.1.4756.20.440.20.1.754 | ColumneddPort4VlanIngressAcceptanceLocal | read-write | current | EDD Series card Port VLAN Configuration : Port4 - Ingress Acceptance 0: Tagged and untagged 1: Tagged only 2: Untagged only |
| 1.3.6.1.4.1.4756.20.440.20.1.755 | ColumneddPort4VlanEgressTaggingLocal | read-write | current | EDD Series card Port VLAN Configuration : Port4 - Egress Tagging 0: Untag port vlan 1: Tag all 2: Untag all |
| 1.3.6.1.4.1.4756.20.440.20.1.756 | ColumneddPort4AllowedVLANSLocal | read-write | current | EDD Series card Global VLAN Configuration: Port4 - Allowed VLANs By default, only VLAN 1 is enabled. More VLANs may be created by using a list syntax where the… |
| 1.3.6.1.4.1.4756.20.440.20.1.757 | ColumneddPort4ForbiddenVLANSLocal | read-write | current | EDD Series card Global VLAN Configuration: Port4 - Forbidden VLANs By default, the field is left blank, which means that the port may become a member of all po… |
| 1.3.6.1.4.1.4756.20.440.20.1.758 | ColumneddDNSServerTypeLocal | read-write | current | EDD Series card IP Configuration: This setting controls the DNS name resolution done by the switch. The following modes are supported: 1:From any DHCP interfac… |
| 1.3.6.1.4.1.4756.20.440.20.1.759 | ColumneddDNSServerSettingLocal | read-write | current | EDD Series card IP Configuration: If iDNSServerType setting '3:Configured',this value must setting IP address format as below: Dotted Decimal Notation refers t… |
| 1.3.6.1.4.1.4756.20.440.20.1.760 | ColumneddDNSproxyLocal | read-write | current | EDD Series card IP Configuration: When DNS proxy is enabled, system will relay DNS requests to the currently configured DNS server, and reply as a DNS resolver… |
| 1.3.6.1.4.1.4756.20.440.20.1.761 | ColumneddAddIPV4InterfaceLocal | read-write | current | EDD Series card IP Interfaces: Add a new IP VLAN Interface: Syntax: [<Interface>] [<vlan_list>] [<IPV4_Addr>] [<IPV4_MASK>] Interface : 1~4 |
| 1.3.6.1.4.1.4756.20.440.20.1.762 | ColumneddDeleteInterfaceLocal | read-write | current | EDD Series card IP Interfaces: Delete a IPv4/v6 VLAN Interface: Syntax: [<Interface>] Interface: 1~4 |
| 1.3.6.1.4.1.4756.20.440.20.1.763 | ColumneddIPInterface1VLANLocal | read-only | current | EDD Series card IP Interfaces: The VLAN associated with the IP interface. Only ports in this VLAN will be able to access the IP interface. This field is only a… |
| 1.3.6.1.4.1.4756.20.440.20.1.764 | ColumneddIPInterface1DHCPLocal | read-write | current | EDD Series card IP Interfaces: DHCP |
| 1.3.6.1.4.1.4756.20.440.20.1.765 | ColumneddIPInterface1FallbackLocal | read-write | current | EDD Series card IP Interfaces: Fallback |
| 1.3.6.1.4.1.4756.20.440.20.1.766 | ColumneddIPInterface1IPV4AddressLocal | read-only | current | EDD Series card IP Interfaces: IPV4 Address |
| 1.3.6.1.4.1.4756.20.440.20.1.767 | ColumneddIPInterface1IPV4MASKLenLocal | read-only | current | EDD Series card IP Interfaces: IPV4 MASK Length |
| 1.3.6.1.4.1.4756.20.440.20.1.768 | ColumneddIPInterface2VLANLocal | read-only | current | EDD Series card IP Interfaces: The VLAN associated with the IP interface. Only ports in this VLAN will be able to access the IP interface. This field is only a… |
| 1.3.6.1.4.1.4756.20.440.20.1.769 | ColumneddIPInterface2DHCPLocal | read-write | current | EDD Series card IP Interfaces: DHCP |
| 1.3.6.1.4.1.4756.20.440.20.1.770 | ColumneddIPInterface2FallbackLocal | read-write | current | EDD Series card IP Interfaces: Fallback |
| 1.3.6.1.4.1.4756.20.440.20.1.771 | ColumneddIPInterface2IPV4AddressLocal | read-only | current | EDD Series card IP Interfaces: IPV4 Address |
| 1.3.6.1.4.1.4756.20.440.20.1.772 | ColumneddIPInterface2IPV4MASKLenLocal | read-only | current | EDD Series card IP Interfaces: IPV4 MASK Length |
| 1.3.6.1.4.1.4756.20.440.20.1.773 | ColumneddIPInterface3VLANLocal | read-only | current | EDD Series card IP Interfaces: The VLAN associated with the IP interface. Only ports in this VLAN will be able to access the IP interface. This field is only a… |
| 1.3.6.1.4.1.4756.20.440.20.1.774 | ColumneddIPInterface3DHCPLocal | read-write | current | EDD Series card IP Interfaces: DHCP |
| 1.3.6.1.4.1.4756.20.440.20.1.775 | ColumneddIPInterface3FallbackLocal | read-write | current | EDD Series card IP Interfaces: Fallback |
| 1.3.6.1.4.1.4756.20.440.20.1.776 | ColumneddIPInterface3IPV4AddressLocal | read-only | current | EDD Series card IP Interfaces: IPV4 Address |
| 1.3.6.1.4.1.4756.20.440.20.1.777 | ColumneddIPInterface3IPV4MASKLenLocal | read-only | current | EDD Series card IP Interfaces: IPV4 MASK Length |
| 1.3.6.1.4.1.4756.20.440.20.1.778 | ColumneddIPInterface4VLANLocal | read-only | current | EDD Series card IP Interfaces: The VLAN associated with the IP interface. Only ports in this VLAN will be able to access the IP interface. This field is only a… |
| 1.3.6.1.4.1.4756.20.440.20.1.779 | ColumneddIPInterface4DHCPLocal | read-write | current | EDD Series card IP Interfaces: DHCP |
| 1.3.6.1.4.1.4756.20.440.20.1.780 | ColumneddIPInterface4FallbackLocal | read-write | current | EDD Series card IP Interfaces: Fallback |
| 1.3.6.1.4.1.4756.20.440.20.1.781 | ColumneddIPInterface4IPV4AddressLocal | read-only | current | EDD Series card IP Interfaces: IPV4 Address |
| 1.3.6.1.4.1.4756.20.440.20.1.782 | ColumneddIPInterface4IPV4MASKLenLocal | read-only | current | EDD Series card IP Interfaces: IPV4 MASK Length |
| 1.3.6.1.4.1.4756.20.440.20.1.783 | ColumneddAddIPV6InterfaceLocal | read-write | current | EDD Series card IP Interfaces: Add a new IPv6 VLAN Interface: Syntax: [<Interface>] [<vlan_list>] [<IPV4_Addr>] [<IPV4_MASK>] Interface : 1~4 |
| 1.3.6.1.4.1.4756.20.440.20.1.784 | ColumneddIPInterface1IPV6AddressLocal | read-only | current | EDD Series card IP Interfaces: IPV6 Address |
| 1.3.6.1.4.1.4756.20.440.20.1.785 | ColumneddIPInterface1IPV6MASKLenLocal | read-only | current | EDD Series card IP Interfaces: IPV6 MASK Length |
| 1.3.6.1.4.1.4756.20.440.20.1.786 | ColumneddIPInterface2IPV6AddressLocal | read-only | current | EDD Series card IP Interfaces: IPV6 Address |
| 1.3.6.1.4.1.4756.20.440.20.1.787 | ColumneddIPInterface2IPV6MASKLenLocal | read-only | current | EDD Series card IP Interfaces: IPV6 MASK Length |
| 1.3.6.1.4.1.4756.20.440.20.1.788 | ColumneddIPInterface3IPV6AddressLocal | read-only | current | EDD Series card IP Interfaces: IPV6 Address |
| 1.3.6.1.4.1.4756.20.440.20.1.789 | ColumneddIPInterface3IPV6MASKLenLocal | read-only | current | EDD Series card IP Interfaces: IPV6 MASK Length |
| 1.3.6.1.4.1.4756.20.440.20.1.790 | ColumneddIPInterface4IPV6AddressLocal | read-only | current | EDD Series card IP Interfaces: IPV6 Address |
| 1.3.6.1.4.1.4756.20.440.20.1.791 | ColumneddIPInterface4IPV6MASKLenLocal | read-only | current | EDD Series card IP Interfaces: IPV6 MASK Length |
| 1.3.6.1.4.1.4756.20.440.20.1.792 | ColumneddPort1ALSLocal | read-write | current | EDD Series card Port1 auto laser shutdown: 0: Disable 1: Enable |
| 1.3.6.1.4.1.4756.20.440.20.1.793 | ColumneddPort2ALSLocal | read-write | current | EDD Series card Port2 auto laser shutdown: 0: Disable 1: Enable |
| 1.3.6.1.4.1.4756.20.440.20.1.794 | ColumneddPort3ALSLocal | read-write | current | EDD Series card Port3 auto laser shutdown (MX210 only): 0: Disable 1: Enable |
| 1.3.6.1.4.1.4756.20.440.20.1.795 | ColumneddPort1LLFLogicLocal | read-write | current | EDD Series card Port1 link loss forwarding - Logic 0: AND 1: OR |
| 1.3.6.1.4.1.4756.20.440.20.1.796 | ColumneddPort1LLFLogicPort2Local | read-write | current | EDD Series card Port1 link loss forwarding - Link/Rx Loss Port2 0: NO 1: YES |
| 1.3.6.1.4.1.4756.20.440.20.1.797 | ColumneddPort1LLFLogicPort3Local | read-write | current | EDD Series card Port1 link loss forwarding - Link/Rx Loss Port3 0: NO 1: YES |
| 1.3.6.1.4.1.4756.20.440.20.1.798 | ColumneddPort1LLFLogicPort4Local | read-write | current | EDD Series card Port1 link loss forwarding - Link/Rx Loss Port4 0: NO 1: YES |
| 1.3.6.1.4.1.4756.20.440.20.1.799 | ColumneddPort2LLFLogicLocal | read-write | current | EDD Series card Port2 link loss forwarding - Logic 0: AND 1: OR |
| 1.3.6.1.4.1.4756.20.440.20.1.800 | ColumneddPort2LLFLogicPort1Local | read-write | current | EDD Series card Port2 link loss forwarding - Link/Rx Loss Port1 0: NO 1: YES |
| 1.3.6.1.4.1.4756.20.440.20.1.801 | ColumneddPort2LLFLogicPort3Local | read-write | current | EDD Series card Port2 link loss forwarding - Link/Rx Loss Port3 0: NO 1: YES |
| 1.3.6.1.4.1.4756.20.440.20.1.802 | ColumneddPort2LLFLogicPort4Local | read-write | current | EDD Series card Port2 link loss forwarding - Link/Rx Loss Port4 0: NO 1: YES |
| 1.3.6.1.4.1.4756.20.440.20.1.803 | ColumneddPort3LLFLogicLocal | read-write | current | EDD Series card Port1 link loss forwarding - Logic 0: AND 1: OR |
| 1.3.6.1.4.1.4756.20.440.20.1.804 | ColumneddPort3LLFLogicPort1Local | read-write | current | EDD Series card Port3 link loss forwarding - Link/Rx Loss Port1 0: NO 1: YES |
| 1.3.6.1.4.1.4756.20.440.20.1.805 | ColumneddPort3LLFLogicPort2Local | read-write | current | EDD Series card Port3 link loss forwarding - Link/Rx Loss Port2 0: NO 1: YES |
| 1.3.6.1.4.1.4756.20.440.20.1.806 | ColumneddPort3LLFLogicPort4Local | read-write | current | EDD Series card Port3 link loss forwarding - Link/Rx Loss Port4 0: NO 1: YES |
| 1.3.6.1.4.1.4756.20.440.20.1.807 | ColumneddPort4LLFLogicLocal | read-write | current | EDD Series card Port4 link loss forwarding - Logic 0: AND 1: OR |
| 1.3.6.1.4.1.4756.20.440.20.1.808 | ColumneddPort4LLFLogicPort1Local | read-write | current | EDD Series card Port4 link loss forwarding - Link/Rx Loss Port1 0: NO 1: YES |
| 1.3.6.1.4.1.4756.20.440.20.1.809 | ColumneddPort4LLFLogicPort2Local | read-write | current | EDD Series card Port4 link loss forwarding - Link/Rx Loss Port2 0: NO 1: YES |
| 1.3.6.1.4.1.4756.20.440.20.1.810 | ColumneddPort4LLFLogicPort3Local | read-write | current | EDD Series card Port4 link loss forwarding - Link/Rx Loss Port3 0: NO 1: YES |
| 1.3.6.1.4.1.4756.20.440.20.1.811 | ColumneddQOSPort1IngressLocal | read-write | current | EDD Series card QOS Port1 Ingress Enabled 0: NO 1: YES |
| 1.3.6.1.4.1.4756.20.440.20.1.812 | ColumneddQOSPort1IngressRateLocal | read-write | current | EDD Series card QOS Port1 Ingress Rate |
| 1.3.6.1.4.1.4756.20.440.20.1.813 | ColumneddQOSPort1IngressRateUnitLocal | read-write | current | EDD Series card QOS Port1 Ingress Rate Unit 0: Kbps 1: Mbps 2: fps 3: kfps |
| 1.3.6.1.4.1.4756.20.440.20.1.814 | ColumneddQOSPort1IngressFlowControlLocal | read-write | current | EDD Series card QOS Port1 Ingress Flow Control 0: NO 1: YES |
| 1.3.6.1.4.1.4756.20.440.20.1.815 | ColumneddQOSPort2IngressLocal | read-write | current | EDD Series card QOS Port2 Ingress Enabled 0: NO 1: YES |
| 1.3.6.1.4.1.4756.20.440.20.1.816 | ColumneddQOSPort2IngressRateLocal | read-write | current | EDD Series card QOS Port2 Ingress Rate |
| 1.3.6.1.4.1.4756.20.440.20.1.817 | ColumneddQOSPort2IngressRateUnitLocal | read-write | current | EDD Series card QOS Port2 Ingress Rate Unit 0: Kbps 1: Mbps 2: fps 3: kfps |
| 1.3.6.1.4.1.4756.20.440.20.1.818 | ColumneddQOSPort2IngressFlowControlLocal | read-write | current | EDD Series card QOS Port2 Ingress Flow Control 0: NO 1: YES |
| 1.3.6.1.4.1.4756.20.440.20.1.819 | ColumneddQOSPort3IngressLocal | read-write | current | EDD Series card QOS Port3 Ingress Enabled 0: NO 1: YES |
| 1.3.6.1.4.1.4756.20.440.20.1.820 | ColumneddQOSPort3IngressRateLocal | read-write | current | EDD Series card QOS Port3 Ingress Rate |
| 1.3.6.1.4.1.4756.20.440.20.1.821 | ColumneddQOSPort3IngressRateUnitLocal | read-write | current | EDD Series card QOS Port3 Ingress Rate Unit 0: Kbps 1: Mbps 2: fps 3: kfps |
| 1.3.6.1.4.1.4756.20.440.20.1.822 | ColumneddQOSPort3IngressFlowControlLocal | read-write | current | EDD Series card QOS Port3 Ingress Flow Control 0: NO 1: YES |
| 1.3.6.1.4.1.4756.20.440.20.1.823 | ColumneddQOSPort4IngressLocal | read-write | current | EDD Series card QOS Port4 Ingress Enabled 0: NO 1: YES |
| 1.3.6.1.4.1.4756.20.440.20.1.824 | ColumneddQOSPort4IngressRateLocal | read-write | current | EDD Series card QOS Port4 Ingress Rate |
| 1.3.6.1.4.1.4756.20.440.20.1.825 | ColumneddQOSPort4IngressRateUnitLocal | read-write | current | EDD Series card QOS Port4 Ingress Rate Unit 0: Kbps 1: Mbps 2: fps 3: kfps |
| 1.3.6.1.4.1.4756.20.440.20.1.826 | ColumneddQOSPort4IngressFlowControlLocal | read-write | current | EDD Series card QOS Port4 Ingress Flow Control 0: NO 1: YES |
| 1.3.6.1.4.1.4756.20.440.20.1.827 | ColumneddQOSPort1EgressLocal | read-write | current | EDD Series card QOS Port1 Egress Enabled 0: NO 1: YES |
| 1.3.6.1.4.1.4756.20.440.20.1.828 | ColumneddQOSPort1EgressRateLocal | read-write | current | EDD Series card QOS Port1 Egress Rate |
| 1.3.6.1.4.1.4756.20.440.20.1.829 | ColumneddQOSPort1EgressRateUnitLocal | read-write | current | EDD Series card QOS Port1 Egress Rate Unit 0: Kbps 1: Mbps |
| 1.3.6.1.4.1.4756.20.440.20.1.830 | ColumneddQOSPort2EgressLocal | read-write | current | EDD Series card QOS Port2 Egress Enabled 0: NO 1: YES |
| 1.3.6.1.4.1.4756.20.440.20.1.831 | ColumneddQOSPort2EgressRateLocal | read-write | current | EDD Series card QOS Port2 Egress Rate |
| 1.3.6.1.4.1.4756.20.440.20.1.832 | ColumneddQOSPort2EgressRateUnitLocal | read-write | current | EDD Series card QOS Port2 Egress Rate Unit 0: Kbps 1: Mbps |
| 1.3.6.1.4.1.4756.20.440.20.1.833 | ColumneddQOSPort3EgressLocal | read-write | current | EDD Series card QOS Port3 Egress Enabled 0: NO 1: YES |
| 1.3.6.1.4.1.4756.20.440.20.1.834 | ColumneddQOSPort3EgressRateLocal | read-write | current | EDD Series card QOS Port3 Egress Rate |
| 1.3.6.1.4.1.4756.20.440.20.1.835 | ColumneddQOSPort3EgressRateUnitLocal | read-write | current | EDD Series card QOS Port3 Egress Rate Unit 0: Kbps 1: Mbps |
| 1.3.6.1.4.1.4756.20.440.20.1.836 | ColumneddQOSPort4EgressLocal | read-write | current | EDD Series card QOS Port4 Egress Enabled 0: NO 1: YES |
| 1.3.6.1.4.1.4756.20.440.20.1.837 | ColumneddQOSPort4EgressRateLocal | read-write | current | EDD Series card QOS Port4 Egress Rate |
| 1.3.6.1.4.1.4756.20.440.20.1.838 | ColumneddQOSPort4EgressRateUnitLocal | read-write | current | EDD Series card QOS Port4 Egress Rate Unit 0: Kbps 1: Mbps |
| 1.3.6.1.4.1.4756.20.440.20.1.839 | ColumneddQOSUnicastLocal | read-write | current | EDD Series card QOS Storm Control Configuration- Unicast 0: NO 1: YES |
| 1.3.6.1.4.1.4756.20.440.20.1.840 | ColumneddQOSUnicastRateLocal | read-write | current | EDD Series card QOS Storm Control Configuration- Unicast Rate The rate unit is packets per second (pps). 0: 1 1: 2 2: 4 3: 8 4: 16 5: 32 6: 64 7: 128 8: 256 9:… |
| 1.3.6.1.4.1.4756.20.440.20.1.841 | ColumneddQOSMulticastLocal | read-write | current | EDD Series card QOS Storm Control Configuration- Multicast 0: NO 1: YES |
| 1.3.6.1.4.1.4756.20.440.20.1.842 | ColumneddQOSMulticastRateLocal | read-write | current | EDD Series card QOS Storm Control Configuration- Multicast The rate unit is packets per second (pps). 0: 1 1: 2 2: 4 3: 8 4: 16 5: 32 6: 64 7: 128 8: 256 9: 51… |
| 1.3.6.1.4.1.4756.20.440.20.1.843 | ColumneddQOSBroadcastLocal | read-write | current | EDD Series card QOS Storm Control Configuration- Broadcast 0: NO 1: YES |
| 1.3.6.1.4.1.4756.20.440.20.1.844 | ColumneddQOSBroadcastRateLocal | read-write | current | EDD Series card QOS Storm Control Configuration- Broadcast The rate unit is packets per second (pps). 0: 1 1: 2 2: 4 3: 8 4: 16 5: 32 6: 64 7: 128 8: 256 9: 51… |
| 1.3.6.1.4.1.4756.20.440.20.1.845 | ColumneddL2CPPort1DMAC0180C2000000Local | read-write | current | EDD Series card Port 1 L2CP Mode 0180C2000000 0: Forward 1: Peer |
| 1.3.6.1.4.1.4756.20.440.20.1.846 | ColumneddL2CPPort1DMAC0180C2000001Local | read-write | current | EDD Series card Port 1 L2CP Mode 0180C2000001 0: Forward 1: Peer |
| 1.3.6.1.4.1.4756.20.440.20.1.847 | ColumneddL2CPPort1DMAC0180C2000002Local | read-write | current | EDD Series card Port 1 L2CP Mode 0180C2000002 0: Forward 1: Peer |
| 1.3.6.1.4.1.4756.20.440.20.1.848 | ColumneddL2CPPort1DMAC0180C2000003Local | read-write | current | EDD Series card Port 1 L2CP Mode 0180C2000003 0: Forward 1: Peer |
| 1.3.6.1.4.1.4756.20.440.20.1.849 | ColumneddL2CPPort1DMAC0180C2000004Local | read-write | current | EDD Series card Port 1 L2CP Mode 0180C2000004 0: Forward 1: Peer |
| 1.3.6.1.4.1.4756.20.440.20.1.850 | ColumneddL2CPPort1DMAC0180C2000005Local | read-write | current | EDD Series card Port 1 L2CP Mode 0180C2000005 0: Forward 1: Peer |
| 1.3.6.1.4.1.4756.20.440.20.1.851 | ColumneddL2CPPort1DMAC0180C2000006Local | read-write | current | EDD Series card Port 1 L2CP Mode 0180C2000006 0: Forward 1: Peer |
| 1.3.6.1.4.1.4756.20.440.20.1.852 | ColumneddL2CPPort1DMAC0180C2000007Local | read-write | current | EDD Series card Port 1 L2CP Mode 0180C2000007 0: Forward 1: Peer |
| 1.3.6.1.4.1.4756.20.440.20.1.853 | ColumneddL2CPPort1DMAC0180C2000008Local | read-write | current | EDD Series card Port 1 L2CP Mode 0180C2000008 0: Forward 1: Peer |
| 1.3.6.1.4.1.4756.20.440.20.1.854 | ColumneddL2CPPort1DMAC0180C2000009Local | read-write | current | EDD Series card Port 1 L2CP Mode 0180C2000009 0: Forward 1: Peer |
| 1.3.6.1.4.1.4756.20.440.20.1.855 | ColumneddL2CPPort1DMAC0180C200000ALocal | read-write | current | EDD Series card Port 1 L2CP Mode 0180C200000A 0: Forward 1: Peer |
| 1.3.6.1.4.1.4756.20.440.20.1.856 | ColumneddL2CPPort1DMAC0180C200000BLocal | read-write | current | EDD Series card Port 1 L2CP Mode 0180C200000B 0: Forward 1: Peer |
| 1.3.6.1.4.1.4756.20.440.20.1.857 | ColumneddL2CPPort1DMAC0180C200000CLocal | read-write | current | EDD Series card Port 1 L2CP Mode 0180C200000C 0: Forward 1: Peer |
| 1.3.6.1.4.1.4756.20.440.20.1.858 | ColumneddL2CPPort1DMAC0180C200000DLocal | read-write | current | EDD Series card Port 1 L2CP Mode 0180C200000D 0: Forward 1: Peer |
| 1.3.6.1.4.1.4756.20.440.20.1.859 | ColumneddL2CPPort1DMAC0180C200000ELocal | read-write | current | EDD Series card Port 1 L2CP Mode 0180C200000E 0: Forward 1: Peer |
| 1.3.6.1.4.1.4756.20.440.20.1.860 | ColumneddL2CPPort1DMAC0180C200000FLocal | read-write | current | EDD Series card Port 1 L2CP Mode 0180C200000F 0: Forward 1: Peer |
| 1.3.6.1.4.1.4756.20.440.20.1.861 | ColumneddL2CPPort1DMAC0180C2000010Local | read-write | current | EDD Series card Port 1 L2CP Mode 0180C2000010 0: Forward 1: Peer |
| 1.3.6.1.4.1.4756.20.440.20.1.862 | ColumneddL2CPPort1DMAC0180C2000020Local | read-write | current | EDD Series card Port 1 L2CP Mode 0180C2000020 0: Forward 1: Peer |
| 1.3.6.1.4.1.4756.20.440.20.1.863 | ColumneddL2CPPort1DMAC0180C2000021Local | read-write | current | EDD Series card Port 1 L2CP Mode 0180C2000021 0: Forward 1: Peer |
| 1.3.6.1.4.1.4756.20.440.20.1.864 | ColumneddL2CPPort1DMAC0180C2000022Local | read-write | current | EDD Series card Port 1 L2CP Mode 0180C2000022 0: Forward 1: Peer |
| 1.3.6.1.4.1.4756.20.440.20.1.865 | ColumneddL2CPPort1DMAC0180C2000023Local | read-write | current | EDD Series card Port 1 L2CP Mode 0180C2000023 0: Forward 1: Peer |
| 1.3.6.1.4.1.4756.20.440.20.1.866 | ColumneddL2CPPort1DMAC0180C2000024Local | read-write | current | EDD Series card Port 1 L2CP Mode 0180C2000024 0: Forward 1: Peer |
| 1.3.6.1.4.1.4756.20.440.20.1.867 | ColumneddL2CPPort1DMAC0180C2000025Local | read-write | current | EDD Series card Port 1 L2CP Mode 0180C2000025 0: Forward 1: Peer |
| 1.3.6.1.4.1.4756.20.440.20.1.868 | ColumneddL2CPPort1DMAC0180C2000026Local | read-write | current | EDD Series card Port 1 L2CP Mode 0180C2000026 0: Forward 1: Peer |
| 1.3.6.1.4.1.4756.20.440.20.1.869 | ColumneddL2CPPort1DMAC0180C2000027Local | read-write | current | EDD Series card Port 1 L2CP Mode 0180C2000027 0: Forward 1: Peer |
| 1.3.6.1.4.1.4756.20.440.20.1.870 | ColumneddL2CPPort1DMAC0180C2000028Local | read-write | current | EDD Series card Port 1 L2CP Mode 0180C2000028 0: Forward 1: Peer |
| 1.3.6.1.4.1.4756.20.440.20.1.871 | ColumneddL2CPPort1DMAC0180C2000029Local | read-write | current | EDD Series card Port 1 L2CP Mode 0180C2000029 0: Forward 1: Peer |
| 1.3.6.1.4.1.4756.20.440.20.1.872 | ColumneddL2CPPort1DMAC0180C200002ALocal | read-write | current | EDD Series card Port 1 L2CP Mode 0180C200002A 0: Forward 1: Peer |
| 1.3.6.1.4.1.4756.20.440.20.1.873 | ColumneddL2CPPort1DMAC0180C200002BLocal | read-write | current | EDD Series card Port 1 L2CP Mode 0180C200002B 0: Forward 1: Peer |
| 1.3.6.1.4.1.4756.20.440.20.1.874 | ColumneddL2CPPort1DMAC0180C200002CLocal | read-write | current | EDD Series card Port 1 L2CP Mode 0180C200002C 0: Forward 1: Peer |
| 1.3.6.1.4.1.4756.20.440.20.1.875 | ColumneddL2CPPort1DMAC0180C200002DLocal | read-write | current | EDD Series card Port 1 L2CP Mode 0180C200002D 0: Forward 1: Peer |
| 1.3.6.1.4.1.4756.20.440.20.1.876 | ColumneddL2CPPort1DMAC0180C200002ELocal | read-write | current | EDD Series card Port 1 L2CP Mode 0180C200002E 0: Forward 1: Peer |
| 1.3.6.1.4.1.4756.20.440.20.1.877 | ColumneddL2CPPort1DMAC0180C200002FLocal | read-write | current | EDD Series card Port 1 L2CP Mode 0180C200002F 0: Forward 1: Peer |
| 1.3.6.1.4.1.4756.20.440.20.1.878 | ColumneddL2CPPort2DMAC0180C2000000Local | read-write | current | EDD Series card Port 2 L2CP Mode 0180C2000000 0: Forward 1: Peer |
| 1.3.6.1.4.1.4756.20.440.20.1.879 | ColumneddL2CPPort2DMAC0180C2000001Local | read-write | current | EDD Series card Port 2 L2CP Mode 0180C2000001 0: Forward 1: Peer |
| 1.3.6.1.4.1.4756.20.440.20.1.880 | ColumneddL2CPPort2DMAC0180C2000002Local | read-write | current | EDD Series card Port 2 L2CP Mode 0180C2000002 0: Forward 1: Peer |
| 1.3.6.1.4.1.4756.20.440.20.1.881 | ColumneddL2CPPort2DMAC0180C2000003Local | read-write | current | EDD Series card Port 2 L2CP Mode 0180C2000003 0: Forward 1: Peer |
| 1.3.6.1.4.1.4756.20.440.20.1.882 | ColumneddL2CPPort2DMAC0180C2000004Local | read-write | current | EDD Series card Port 2 L2CP Mode 0180C2000004 0: Forward 1: Peer |
| 1.3.6.1.4.1.4756.20.440.20.1.883 | ColumneddL2CPPort2DMAC0180C2000005Local | read-write | current | EDD Series card Port 2 L2CP Mode 0180C2000005 0: Forward 1: Peer |
| 1.3.6.1.4.1.4756.20.440.20.1.884 | ColumneddL2CPPort2DMAC0180C2000006Local | read-write | current | EDD Series card Port 2 L2CP Mode 0180C2000006 0: Forward 1: Peer |
| 1.3.6.1.4.1.4756.20.440.20.1.885 | ColumneddL2CPPort2DMAC0180C2000007Local | read-write | current | EDD Series card Port 2 L2CP Mode 0180C2000007 0: Forward 1: Peer |
| 1.3.6.1.4.1.4756.20.440.20.1.886 | ColumneddL2CPPort2DMAC0180C2000008Local | read-write | current | EDD Series card Port 2 L2CP Mode 0180C2000008 0: Forward 1: Peer |
| 1.3.6.1.4.1.4756.20.440.20.1.887 | ColumneddL2CPPort2DMAC0180C2000009Local | read-write | current | EDD Series card Port 2 L2CP Mode 0180C2000009 0: Forward 1: Peer |
| 1.3.6.1.4.1.4756.20.440.20.1.888 | ColumneddL2CPPort2DMAC0180C200000ALocal | read-write | current | EDD Series card Port 2 L2CP Mode 0180C200000A 0: Forward 1: Peer |
| 1.3.6.1.4.1.4756.20.440.20.1.889 | ColumneddL2CPPort2DMAC0180C200000BLocal | read-write | current | EDD Series card Port 2 L2CP Mode 0180C200000B 0: Forward 1: Peer |
| 1.3.6.1.4.1.4756.20.440.20.1.890 | ColumneddL2CPPort2DMAC0180C200000CLocal | read-write | current | EDD Series card Port 2 L2CP Mode 0180C200000C 0: Forward 1: Peer |
| 1.3.6.1.4.1.4756.20.440.20.1.891 | ColumneddL2CPPort2DMAC0180C200000DLocal | read-write | current | EDD Series card Port 2 L2CP Mode 0180C200000A 0: Forward 1: Peer |
| 1.3.6.1.4.1.4756.20.440.20.1.892 | ColumneddL2CPPort2DMAC0180C200000ELocal | read-write | current | EDD Series card Port 2 L2CP Mode 0180C200000E 0: Forward 1: Peer |
| 1.3.6.1.4.1.4756.20.440.20.1.893 | ColumneddL2CPPort2DMAC0180C200000FLocal | read-write | current | EDD Series card Port 2 L2CP Mode 0180C200000F 0: Forward 1: Peer |
| 1.3.6.1.4.1.4756.20.440.20.1.894 | ColumneddL2CPPort2DMAC0180C2000010Local | read-write | current | EDD Series card Port 2 L2CP Mode 0180C2000010 0: Forward 1: Peer |
| 1.3.6.1.4.1.4756.20.440.20.1.895 | ColumneddL2CPPort2DMAC0180C2000020Local | read-write | current | EDD Series card Port 2 L2CP Mode 0180C2000020 0: Forward 1: Peer |
| 1.3.6.1.4.1.4756.20.440.20.1.896 | ColumneddL2CPPort2DMAC0180C2000021Local | read-write | current | EDD Series card Port 2 L2CP Mode 0180C2000021 0: Forward 1: Peer |
| 1.3.6.1.4.1.4756.20.440.20.1.897 | ColumneddL2CPPort2DMAC0180C2000022Local | read-write | current | EDD Series card Port 2 L2CP Mode 0180C2000022 0: Forward 1: Peer |
| 1.3.6.1.4.1.4756.20.440.20.1.898 | ColumneddL2CPPort2DMAC0180C2000023Local | read-write | current | EDD Series card Port 2 L2CP Mode 0180C2000023 0: Forward 1: Peer |
| 1.3.6.1.4.1.4756.20.440.20.1.899 | ColumneddL2CPPort2DMAC0180C2000024Local | read-write | current | EDD Series card Port 2 L2CP Mode 0180C2000024 0: Forward 1: Peer |
| 1.3.6.1.4.1.4756.20.440.20.1.900 | ColumneddL2CPPort2DMAC0180C2000025Local | read-write | current | EDD Series card Port 2 L2CP Mode 0180C2000025 0: Forward 1: Peer |
| 1.3.6.1.4.1.4756.20.440.20.1.901 | ColumneddL2CPPort2DMAC0180C2000026Local | read-write | current | EDD Series card Port 2 L2CP Mode 0180C2000026 0: Forward 1: Peer |
| 1.3.6.1.4.1.4756.20.440.20.1.902 | ColumneddL2CPPort2DMAC0180C2000027Local | read-write | current | EDD Series card Port 2 L2CP Mode 0180C2000027 0: Forward 1: Peer |
| 1.3.6.1.4.1.4756.20.440.20.1.903 | ColumneddL2CPPort2DMAC0180C2000028Local | read-write | current | EDD Series card Port 2 L2CP Mode 0180C2000028 0: Forward 1: Peer |
| 1.3.6.1.4.1.4756.20.440.20.1.904 | ColumneddL2CPPort2DMAC0180C2000029Local | read-write | current | EDD Series card Port 2 L2CP Mode 0180C2000029 0: Forward 1: Peer |
| 1.3.6.1.4.1.4756.20.440.20.1.905 | ColumneddL2CPPort2DMAC0180C200002ALocal | read-write | current | EDD Series card Port 2 L2CP Mode 0180C200002A 0: Forward 1: Peer |
| 1.3.6.1.4.1.4756.20.440.20.1.906 | ColumneddL2CPPort2DMAC0180C200002BLocal | read-write | current | EDD Series card Port 2 L2CP Mode 0180C200002B 0: Forward 1: Peer |
| 1.3.6.1.4.1.4756.20.440.20.1.907 | ColumneddL2CPPort2DMAC0180C200002CLocal | read-write | current | EDD Series card Port 2 L2CP Mode 0180C200002C 0: Forward 1: Peer |
| 1.3.6.1.4.1.4756.20.440.20.1.908 | ColumneddL2CPPort2DMAC0180C200002DLocal | read-write | current | EDD Series card Port 2 L2CP Mode 0180C200002D 0: Forward 1: Peer |
| 1.3.6.1.4.1.4756.20.440.20.1.909 | ColumneddL2CPPort2DMAC0180C200002ELocal | read-write | current | EDD Series card Port 2 L2CP Mode 0180C200002E 0: Forward 1: Peer |
| 1.3.6.1.4.1.4756.20.440.20.1.910 | ColumneddL2CPPort2DMAC0180C200002FLocal | read-write | current | EDD Series card Port 2 L2CP Mode 0180C200002F 0: Forward 1: Peer |
| 1.3.6.1.4.1.4756.20.440.20.1.911 | ColumneddL2CPPort3DMAC0180C2000000Local | read-write | current | EDD Series card Port 3 L2CP Mode 0180C2000000 0: Forward 1: Peer |
| 1.3.6.1.4.1.4756.20.440.20.1.912 | ColumneddL2CPPort3DMAC0180C2000001Local | read-write | current | EDD Series card Port 3 L2CP Mode 0180C2000001 0: Forward 1: Peer |
| 1.3.6.1.4.1.4756.20.440.20.1.913 | ColumneddL2CPPort3DMAC0180C2000002Local | read-write | current | EDD Series card Port 3 L2CP Mode 0180C2000002 0: Forward 1: Peer |
| 1.3.6.1.4.1.4756.20.440.20.1.914 | ColumneddL2CPPort3DMAC0180C2000003Local | read-write | current | EDD Series card Port 3 L2CP Mode 0180C2000003 0: Forward 1: Peer |
| 1.3.6.1.4.1.4756.20.440.20.1.915 | ColumneddL2CPPort3DMAC0180C2000004Local | read-write | current | EDD Series card Port 3 L2CP Mode 0180C2000004 0: Forward 1: Peer |
| 1.3.6.1.4.1.4756.20.440.20.1.916 | ColumneddL2CPPort3DMAC0180C2000005Local | read-write | current | EDD Series card Port 3 L2CP Mode 0180C2000005 0: Forward 1: Peer |
| 1.3.6.1.4.1.4756.20.440.20.1.917 | ColumneddL2CPPort3DMAC0180C2000006Local | read-write | current | EDD Series card Port 3 L2CP Mode 0180C2000006 0: Forward 1: Peer |
| 1.3.6.1.4.1.4756.20.440.20.1.918 | ColumneddL2CPPort3DMAC0180C2000007Local | read-write | current | EDD Series card Port 3 L2CP Mode 0180C2000007 0: Forward 1: Peer |
| 1.3.6.1.4.1.4756.20.440.20.1.919 | ColumneddL2CPPort3DMAC0180C2000008Local | read-write | current | EDD Series card Port 3 L2CP Mode 0180C2000008 0: Forward 1: Peer |
| 1.3.6.1.4.1.4756.20.440.20.1.920 | ColumneddL2CPPort3DMAC0180C2000009Local | read-write | current | EDD Series card Port 3 L2CP Mode 0180C2000009 0: Forward 1: Peer |
| 1.3.6.1.4.1.4756.20.440.20.1.921 | ColumneddL2CPPort3DMAC0180C200000ALocal | read-write | current | EDD Series card Port 3 L2CP Mode 0180C200000A 0: Forward 1: Peer |
| 1.3.6.1.4.1.4756.20.440.20.1.922 | ColumneddL2CPPort3DMAC0180C200000BLocal | read-write | current | EDD Series card Port 3 L2CP Mode 0180C200000B 0: Forward 1: Peer |
| 1.3.6.1.4.1.4756.20.440.20.1.923 | ColumneddL2CPPort3DMAC0180C200000CLocal | read-write | current | EDD Series card Port 3 L2CP Mode 0180C200000C 0: Forward 1: Peer |
| 1.3.6.1.4.1.4756.20.440.20.1.924 | ColumneddL2CPPort3DMAC0180C200000DLocal | read-write | current | EDD Series card Port 3 L2CP Mode 0180C200000D 0: Forward 1: Peer |
| 1.3.6.1.4.1.4756.20.440.20.1.925 | ColumneddL2CPPort3DMAC0180C200000ELocal | read-write | current | EDD Series card Port 3 L2CP Mode 0180C200000E 0: Forward 1: Peer |
| 1.3.6.1.4.1.4756.20.440.20.1.926 | ColumneddL2CPPort3DMAC0180C200000FLocal | read-write | current | EDD Series card Port 3 L2CP Mode 0180C200000F 0: Forward 1: Peer |
| 1.3.6.1.4.1.4756.20.440.20.1.927 | ColumneddL2CPPort3DMAC0180C2000010Local | read-write | current | EDD Series card Port 3 L2CP Mode 0180C2000010 0: Forward 1: Peer |
| 1.3.6.1.4.1.4756.20.440.20.1.928 | ColumneddL2CPPort3DMAC0180C2000020Local | read-write | current | EDD Series card Port 3 L2CP Mode 0180C2000020 0: Forward 1: Peer |
| 1.3.6.1.4.1.4756.20.440.20.1.929 | ColumneddL2CPPort3DMAC0180C2000021Local | read-write | current | EDD Series card Port 3 L2CP Mode 0180C2000021 0: Forward 1: Peer |
| 1.3.6.1.4.1.4756.20.440.20.1.930 | ColumneddL2CPPort3DMAC0180C2000022Local | read-write | current | EDD Series card Port 3 L2CP Mode 0180C2000022 0: Forward 1: Peer |
| 1.3.6.1.4.1.4756.20.440.20.1.931 | ColumneddL2CPPort3DMAC0180C2000023Local | read-write | current | EDD Series card Port 3 L2CP Mode 0180C2000023 0: Forward 1: Peer |
| 1.3.6.1.4.1.4756.20.440.20.1.932 | ColumneddL2CPPort3DMAC0180C2000024Local | read-write | current | EDD Series card Port 3 L2CP Mode 0180C2000024 0: Forward 1: Peer |
| 1.3.6.1.4.1.4756.20.440.20.1.933 | ColumneddL2CPPort3DMAC0180C2000025Local | read-write | current | EDD Series card Port 3 L2CP Mode 0180C2000025 0: Forward 1: Peer |
| 1.3.6.1.4.1.4756.20.440.20.1.934 | ColumneddL2CPPort3DMAC0180C2000026Local | read-write | current | EDD Series card Port 3 L2CP Mode 0180C2000026 0: Forward 1: Peer |
| 1.3.6.1.4.1.4756.20.440.20.1.935 | ColumneddL2CPPort3DMAC0180C2000027Local | read-write | current | EDD Series card Port 3 L2CP Mode 0180C2000027 0: Forward 1: Peer |
| 1.3.6.1.4.1.4756.20.440.20.1.936 | ColumneddL2CPPort3DMAC0180C2000028Local | read-write | current | EDD Series card Port 3 L2CP Mode 0180C2000028 0: Forward 1: Peer |
| 1.3.6.1.4.1.4756.20.440.20.1.937 | ColumneddL2CPPort3DMAC0180C2000029Local | read-write | current | EDD Series card Port 3 L2CP Mode 0180C2000029 0: Forward 1: Peer |
| 1.3.6.1.4.1.4756.20.440.20.1.938 | ColumneddL2CPPort3DMAC0180C200002ALocal | read-write | current | EDD Series card Port 3 L2CP Mode 0180C200002A 0: Forward 1: Peer |
| 1.3.6.1.4.1.4756.20.440.20.1.939 | ColumneddL2CPPort3DMAC0180C200002BLocal | read-write | current | EDD Series card Port 3 L2CP Mode 0180C200002B 0: Forward 1: Peer |
| 1.3.6.1.4.1.4756.20.440.20.1.940 | ColumneddL2CPPort3DMAC0180C200002CLocal | read-write | current | EDD Series card Port 3 L2CP Mode 0180C200002C 0: Forward 1: Peer |
| 1.3.6.1.4.1.4756.20.440.20.1.941 | ColumneddL2CPPort3DMAC0180C200002DLocal | read-write | current | EDD Series card Port 3 L2CP Mode 0180C200002D 0: Forward 1: Peer |
| 1.3.6.1.4.1.4756.20.440.20.1.942 | ColumneddL2CPPort3DMAC0180C200002ELocal | read-write | current | EDD Series card Port 3 L2CP Mode 0180C200002E 0: Forward 1: Peer |
| 1.3.6.1.4.1.4756.20.440.20.1.943 | ColumneddL2CPPort3DMAC0180C200002FLocal | read-write | current | EDD Series card Port 3 L2CP Mode 0180C200002F 0: Forward 1: Peer |
| 1.3.6.1.4.1.4756.20.440.20.1.944 | ColumneddL2CPPort4DMAC0180C2000000Local | read-write | current | EDD Series card Port 4 L2CP Mode 0180C2000000 0: Forward 1: Peer |
| 1.3.6.1.4.1.4756.20.440.20.1.945 | ColumneddL2CPPort4DMAC0180C2000001Local | read-write | current | EDD Series card Port 4 L2CP Mode 0180C2000001 0: Forward 1: Peer |
| 1.3.6.1.4.1.4756.20.440.20.1.946 | ColumneddL2CPPort4DMAC0180C2000002Local | read-write | current | EDD Series card Port 4 L2CP Mode 0180C2000002 0: Forward 1: Peer |
| 1.3.6.1.4.1.4756.20.440.20.1.947 | ColumneddL2CPPort4DMAC0180C2000003Local | read-write | current | EDD Series card Port 4 L2CP Mode 0180C2000003 0: Forward 1: Peer |
| 1.3.6.1.4.1.4756.20.440.20.1.948 | ColumneddL2CPPort4DMAC0180C2000004Local | read-write | current | EDD Series card Port 4 L2CP Mode 0180C2000004 0: Forward 1: Peer |
| 1.3.6.1.4.1.4756.20.440.20.1.949 | ColumneddL2CPPort4DMAC0180C2000005Local | read-write | current | EDD Series card Port 4 L2CP Mode 0180C2000005 0: Forward 1: Peer |
| 1.3.6.1.4.1.4756.20.440.20.1.950 | ColumneddL2CPPort4DMAC0180C2000006Local | read-write | current | EDD Series card Port 4 L2CP Mode 0180C2000006 0: Forward 1: Peer |
| 1.3.6.1.4.1.4756.20.440.20.1.951 | ColumneddL2CPPort4DMAC0180C2000007Local | read-write | current | EDD Series card Port 4 L2CP Mode 0180C2000007 0: Forward 1: Peer |
| 1.3.6.1.4.1.4756.20.440.20.1.952 | ColumneddL2CPPort4DMAC0180C2000008Local | read-write | current | EDD Series card Port 4 L2CP Mode 0180C2000008 0: Forward 1: Peer |
| 1.3.6.1.4.1.4756.20.440.20.1.953 | ColumneddL2CPPort4DMAC0180C2000009Local | read-write | current | EDD Series card Port 4 L2CP Mode 0180C2000009 0: Forward 1: Peer |
| 1.3.6.1.4.1.4756.20.440.20.1.954 | ColumneddL2CPPort4DMAC0180C200000ALocal | read-write | current | EDD Series card Port 4 L2CP Mode 0180C200000A 0: Forward 1: Peer |
| 1.3.6.1.4.1.4756.20.440.20.1.955 | ColumneddL2CPPort4DMAC0180C200000BLocal | read-write | current | EDD Series card Port 4 L2CP Mode 0180C200000B 0: Forward 1: Peer |
| 1.3.6.1.4.1.4756.20.440.20.1.956 | ColumneddL2CPPort4DMAC0180C200000CLocal | read-write | current | EDD Series card Port 4 L2CP Mode 0180C200000C 0: Forward 1: Peer |
| 1.3.6.1.4.1.4756.20.440.20.1.957 | ColumneddL2CPPort4DMAC0180C200000DLocal | read-write | current | EDD Series card Port 4 L2CP Mode 0180C200000D 0: Forward 1: Peer |
| 1.3.6.1.4.1.4756.20.440.20.1.958 | ColumneddL2CPPort4DMAC0180C200000ELocal | read-write | current | EDD Series card Port 4 L2CP Mode 0180C200000E 0: Forward 1: Peer |
| 1.3.6.1.4.1.4756.20.440.20.1.959 | ColumneddL2CPPort4DMAC0180C200000FLocal | read-write | current | EDD Series card Port 4 L2CP Mode 0180C200000F 0: Forward 1: Peer |
| 1.3.6.1.4.1.4756.20.440.20.1.960 | ColumneddL2CPPort4DMAC0180C2000010Local | read-write | current | EDD Series card Port 4 L2CP Mode 0180C2000010 0: Forward 1: Peer |
| 1.3.6.1.4.1.4756.20.440.20.1.961 | ColumneddL2CPPort4DMAC0180C2000020Local | read-write | current | EDD Series card Port 4 L2CP Mode 0180C2000020 0: Forward 1: Peer |
| 1.3.6.1.4.1.4756.20.440.20.1.962 | ColumneddL2CPPort4DMAC0180C2000021Local | read-write | current | EDD Series card Port 4 L2CP Mode 0180C2000021 0: Forward 1: Peer |
| 1.3.6.1.4.1.4756.20.440.20.1.963 | ColumneddL2CPPort4DMAC0180C2000022Local | read-write | current | EDD Series card Port 4 L2CP Mode 0180C2000022 0: Forward 1: Peer |
| 1.3.6.1.4.1.4756.20.440.20.1.964 | ColumneddL2CPPort4DMAC0180C2000023Local | read-write | current | EDD Series card Port 4 L2CP Mode 0180C2000023 0: Forward 1: Peer |
| 1.3.6.1.4.1.4756.20.440.20.1.965 | ColumneddL2CPPort4DMAC0180C2000024Local | read-write | current | EDD Series card Port 4 L2CP Mode 0180C2000024 0: Forward 1: Peer |
| 1.3.6.1.4.1.4756.20.440.20.1.966 | ColumneddL2CPPort4DMAC0180C2000025Local | read-write | current | EDD Series card Port 4 L2CP Mode 0180C2000025 0: Forward 1: Peer |
| 1.3.6.1.4.1.4756.20.440.20.1.967 | ColumneddL2CPPort4DMAC0180C2000026Local | read-write | current | EDD Series card Port 4 L2CP Mode 0180C2000026 0: Forward 1: Peer |
| 1.3.6.1.4.1.4756.20.440.20.1.968 | ColumneddL2CPPort4DMAC0180C2000027Local | read-write | current | EDD Series card Port 4 L2CP Mode 0180C2000027 0: Forward 1: Peer |
| 1.3.6.1.4.1.4756.20.440.20.1.969 | ColumneddL2CPPort4DMAC0180C2000028Local | read-write | current | EDD Series card Port 4 L2CP Mode 0180C2000028 0: Forward 1: Peer |
| 1.3.6.1.4.1.4756.20.440.20.1.970 | ColumneddL2CPPort4DMAC0180C2000029Local | read-write | current | EDD Series card Port 4 L2CP Mode 0180C2000029 0: Forward 1: Peer |
| 1.3.6.1.4.1.4756.20.440.20.1.971 | ColumneddL2CPPort4DMAC0180C200002ALocal | read-write | current | EDD Series card Port 4 L2CP Mode 0180C200002A 0: Forward 1: Peer |
| 1.3.6.1.4.1.4756.20.440.20.1.972 | ColumneddL2CPPort4DMAC0180C200002BLocal | read-write | current | EDD Series card Port 4 L2CP Mode 0180C200002B 0: Forward 1: Peer |
| 1.3.6.1.4.1.4756.20.440.20.1.973 | ColumneddL2CPPort4DMAC0180C200002CLocal | read-write | current | EDD Series card Port 4 L2CP Mode 0180C200002C 0: Forward 1: Peer |
| 1.3.6.1.4.1.4756.20.440.20.1.974 | ColumneddL2CPPort4DMAC0180C200002DLocal | read-write | current | EDD Series card Port 4 L2CP Mode 0180C200002D 0: Forward 1: Peer |
| 1.3.6.1.4.1.4756.20.440.20.1.975 | ColumneddL2CPPort4DMAC0180C200002ELocal | read-write | current | EDD Series card Port 4 L2CP Mode 0180C200002E 0: Forward 1: Peer |
| 1.3.6.1.4.1.4756.20.440.20.1.976 | ColumneddL2CPPort4DMAC0180C200002FLocal | read-write | current | EDD Series card Port 4 L2CP Mode 0180C200002F 0: Forward 1: Peer |
| 1.3.6.1.4.1.4756.20.440.20.1.977 | ColumneddPort1MEPInstanceLocal | read-write | current | EDD Series card Port 1 MEP Instance 'MEP ID' must be an integer value between 0 and 8191. |
| 1.3.6.1.4.1.4756.20.440.20.1.978 | ColumneddPort1MEPLogicLocal | read-write | current | EDD Series card Port 1 MEP Logic 0: And 1: OR |
| 1.3.6.1.4.1.4756.20.440.20.1.979 | ColumneddPort2MEPInstanceLocal | read-write | current | EDD Series card Port 2 MEP Instance 'MEP ID' must be an integer value between 0 and 8191. |
| 1.3.6.1.4.1.4756.20.440.20.1.980 | ColumneddPort2MEPLogicLocal | read-write | current | EDD Series card Port 2 MEP Logic 0: And 1: OR |
| 1.3.6.1.4.1.4756.20.440.20.1.981 | ColumneddPort3MEPInstanceLocal | read-write | current | EDD Series card Port 3 MEP Instance 'MEP ID' must be an integer value between 0 and 8191. |
| 1.3.6.1.4.1.4756.20.440.20.1.982 | ColumneddPort3MEPLogicLocal | read-write | current | EDD Series card Port 3 MEP Logic 0: And 1: OR |
| 1.3.6.1.4.1.4756.20.440.20.1.983 | ColumneddPort4MEPInstanceLocal | read-write | current | EDD Series card Port 4 MEP Instance 'MEP ID' must be an integer value between 0 and 8191. |
| 1.3.6.1.4.1.4756.20.440.20.1.984 | ColumneddPort4MEPLogicLocal | read-write | current | EDD Series card Port 4 MEP Logic 0: And 1: OR |
| 1.3.6.1.4.1.4756.20.441 | NodeeddRemoteACards | |||
| 1.3.6.1.4.1.4756.20.441.20 | TableeddRemoteATable | not-accessible | current | A list of RemoteA FRM220-EDD series card entries. |
| 1.3.6.1.4.1.4756.20.441.20.1 | RoweddRemoteAEntry | not-accessible | current | An entry containing management information applicable to a particular FRM220-EDD series card. |
| 1.3.6.1.4.1.4756.20.441.20.1.1 | ColumneddChassisIndexRemoteA | read-only | current | A unique value for each card. It starts from 0 to 9 contiguously. |
| 1.3.6.1.4.1.4756.20.441.20.1.2 | ColumneddSlotIndexRemoteA | read-only | current | A unique value for each card. It starts from 1 to 20 contiguously. |
| 1.3.6.1.4.1.4756.20.441.20.1.3 | ColumneddCardHWVerRemoteA | read-only | current | EDD Series card hardware version x.xxx |
| 1.3.6.1.4.1.4756.20.441.20.1.4 | ColumneddCardFWVerRemoteA | read-only | current | EDD Series card firmware version x.xxx |
| 1.3.6.1.4.1.4756.20.441.20.1.5 | ColumneddCardCPLDVerRemoteA | read-only | current | EDD Series card CPLD version x.xxx |
| 1.3.6.1.4.1.4756.20.441.20.1.6 | ColumneddCardFPGAVerRemoteA | read-only | current | EDD Series card FPGA version x.xxx |
| 1.3.6.1.4.1.4756.20.441.20.1.7 | ColumneddModelRemoteA | read-only | current | Card Type: 0:MX210 1:MSW202 |
| 1.3.6.1.4.1.4756.20.441.20.1.8 | ColumneddPort1LinkstsRemoteA | read-only | current | EDD Series card Port1 link status: 0:Link down 1:Link up |
| 1.3.6.1.4.1.4756.20.441.20.1.9 | ColumneddPort1SpeedstsRemoteA | read-only | current | EDD Series card Port1 speed status 10Base-T 100Base-Tx 1000Base-Tx 2.5G |
| 1.3.6.1.4.1.4756.20.441.20.1.10 | ColumneddPort1DuplexstsRemoteA | read-only | current | EDD Series card Port1 duplex status 0: Half 1: Full |
| 1.3.6.1.4.1.4756.20.441.20.1.11 | ColumneddPort1RxPausestsRemoteA | read-only | current | EDD Series card Port1 rx pause status 0: No 1: Yes |
| 1.3.6.1.4.1.4756.20.441.20.1.12 | ColumneddPort1TxPausestsRemoteA | read-only | current | EDD Series card Port1 tx pause status 0: No 1: Yes |
| 1.3.6.1.4.1.4756.20.441.20.1.13 | ColumneddPort2LinkstsRemoteA | read-only | current | EDD Series card Port2 link status: 0:Link down 1:Link up |
| 1.3.6.1.4.1.4756.20.441.20.1.14 | ColumneddPort2SpeedstsRemoteA | read-only | current | EDD Series card Port2 speed status 10Base-T 100Base-Tx 1000Base-Tx 2.5G |
| 1.3.6.1.4.1.4756.20.441.20.1.15 | ColumneddPort2DuplexstsRemoteA | read-only | current | EDD Series card Port2 duplex status 0: Half 1: Full |
| 1.3.6.1.4.1.4756.20.441.20.1.16 | ColumneddPort2RxPausestsRemoteA | read-only | current | EDD Series card Port2 rx pause status 0: No 1: Yes |
| 1.3.6.1.4.1.4756.20.441.20.1.17 | ColumneddPort2TxPausestsRemoteA | read-only | current | EDD Series card Port2 tx pause status 0: No 1: Yes |
| 1.3.6.1.4.1.4756.20.441.20.1.18 | ColumneddPort3LinkstsRemoteA | read-only | current | EDD Series card Port3 link status: 0:Link down 1:Link up |
| 1.3.6.1.4.1.4756.20.441.20.1.19 | ColumneddPort3SpeedstsRemoteA | read-only | current | EDD Series card Port3 speed status 10Base-T 100Base-Tx 1000Base-Tx |
| 1.3.6.1.4.1.4756.20.441.20.1.20 | ColumneddPort3DuplexstsRemoteA | read-only | current | EDD Series card Port3 duplex status 0: Half 1: Full |
| 1.3.6.1.4.1.4756.20.441.20.1.21 | ColumneddPort3RxPausestsRemoteA | read-only | current | EDD Series card Port3 rx pause status 0: No 1: Yes |
| 1.3.6.1.4.1.4756.20.441.20.1.22 | ColumneddPort3TxPausestsRemoteA | read-only | current | EDD Series card Port3 tx pause status 0: No 1: Yes |
| 1.3.6.1.4.1.4756.20.441.20.1.23 | ColumneddPort4LinkstsRemoteA | read-only | current | EDD Series card Port4 link status: 0:Link down 1:Link up |
| 1.3.6.1.4.1.4756.20.441.20.1.24 | ColumneddPort4SpeedstsRemoteA | read-only | current | EDD Series card Port4 speed status 10Base-T 100Base-Tx 1000Base-Tx |
| 1.3.6.1.4.1.4756.20.441.20.1.25 | ColumneddPort4DuplexstsRemoteA | read-only | current | EDD Series card Port4 duplex status 0: Half 1: Full |
| 1.3.6.1.4.1.4756.20.441.20.1.26 | ColumneddPort4RxPausestsRemoteA | read-only | current | EDD Series card Port4 rx pause status 0: No 1: Yes |
| 1.3.6.1.4.1.4756.20.441.20.1.27 | ColumneddPort4TxPausestsRemoteA | read-only | current | EDD Series card Port4 tx pause status 0: No 1: Yes |
| 1.3.6.1.4.1.4756.20.441.20.1.28 | ColumneddPort1SpeedConfRemoteA | read-write | current | EDD Series card Port1 speed config 0: disable 1: auto 2: 100M FDX 3: 1G FDX 4: 2.5G FDX |
| 1.3.6.1.4.1.4756.20.441.20.1.29 | ColumneddPort1flowConrolRemoteA | read-write | current | EDD Series card Port1 flow control config 0: no 1: yes |
| 1.3.6.1.4.1.4756.20.441.20.1.30 | ColumneddPort1MaxFrameRemoteA | read-write | current | EDD Series card Port1 max frame config |
| 1.3.6.1.4.1.4756.20.441.20.1.31 | ColumneddPort2SpeedConfRemoteA | read-write | current | EDD Series card Port2 speed config 0: disable 1: auto 2: 100M FDX 3: 1G FDX 4: 2.5G FDX |
| 1.3.6.1.4.1.4756.20.441.20.1.32 | ColumneddPort2flowConrolRemoteA | read-write | current | EDD Series card Port2 flow control config 0: no 1: yes |
| 1.3.6.1.4.1.4756.20.441.20.1.33 | ColumneddPort2MaxFrameRemoteA | read-write | current | EDD Series card Port2 max frame config |
| 1.3.6.1.4.1.4756.20.441.20.1.34 | ColumneddPort3SpeedConfRemoteA | read-write | current | EDD Series card Port3 speed config 0: disable 1: auto 2: 10M HDX 3: 10M FDX 4: 100M HDX 5: 100M FDX 6: 1G FDX |
| 1.3.6.1.4.1.4756.20.441.20.1.35 | ColumneddPort3flowConrolRemoteA | read-write | current | EDD Series card Port3 flow control config 0: no 1: yes |
| 1.3.6.1.4.1.4756.20.441.20.1.36 | ColumneddPort3MaxFrameRemoteA | read-write | current | EDD Series card Port3 max frame config |
| 1.3.6.1.4.1.4756.20.441.20.1.37 | ColumneddPort3CollisionModeRemoteA | read-write | current | EDD Series card Port3 collision mode config.(MSW202 only) 0: Discard 1: Restart |
| 1.3.6.1.4.1.4756.20.441.20.1.38 | ColumneddPort4SpeedConfRemoteA | read-write | current | EDD Series card Port4 speed config 0: disable 1: auto 2: 10M HDX 3: 10M FDX 4: 100M HDX 5: 100M FDX 6: 1G FDX |
| 1.3.6.1.4.1.4756.20.441.20.1.39 | ColumneddPort4flowConrolRemoteA | read-write | current | EDD Series card Port4 flow control config 0: no 1: yes |
| 1.3.6.1.4.1.4756.20.441.20.1.40 | ColumneddPort4MaxFrameRemoteA | read-write | current | EDD Series card Port4 max frame config |
| 1.3.6.1.4.1.4756.20.441.20.1.41 | ColumneddPort4CollisionModeRemoteA | read-write | current | EDD Series card Port4 collision mode config 0: Discard 1: Restart |
| 1.3.6.1.4.1.4756.20.441.20.1.42 | ColumneddSaveStartupCongRemoteA | read-write | current | EDD Series card save start-up config 0: OFF 1: Action |
| 1.3.6.1.4.1.4756.20.441.20.1.43 | ColumneddPortResetRemoteA | read-write | current | EDD Series card port reset 0: OFF 1: Action |
| 1.3.6.1.4.1.4756.20.441.20.1.44 | ColumneddSetDefaultRemoteA | read-write | current | EDD Series card set to default config 0: OFF 1: Action |
| 1.3.6.1.4.1.4756.20.441.20.1.45 | ColumneddMuxModeRemoteA | read-write | current | EDD Series card Mux mode (MX210 only) 0: Disable 1: Switch 2: Isolate 3: VLAN |
| 1.3.6.1.4.1.4756.20.441.20.1.46 | ColumneddPort1PacketsRxRemoteA | read-only | current | EDD Series card port1 traffic overview:: Packets Rx |
| 1.3.6.1.4.1.4756.20.441.20.1.47 | ColumneddPort1PacketsTxRemoteA | read-only | current | EDD Series card port1 traffic overview:: Packets Tx |
| 1.3.6.1.4.1.4756.20.441.20.1.48 | ColumneddPort1BytesRxRemoteA | read-only | current | EDD Series card port1 traffic overview:: Bytes Rx |
| 1.3.6.1.4.1.4756.20.441.20.1.49 | ColumneddPort1BytesTxRemoteA | read-only | current | EDD Series card port1 traffic overview:: Bytes Tx |
| 1.3.6.1.4.1.4756.20.441.20.1.50 | ColumneddPort1ErrorsRxRemoteA | read-only | current | EDD Series card port1 traffic overview:: Errors Rx |
| 1.3.6.1.4.1.4756.20.441.20.1.51 | ColumneddPort1ErrorsTxRemoteA | read-only | current | EDD Series card port1 traffic overview:: Errors Tx |
| 1.3.6.1.4.1.4756.20.441.20.1.52 | ColumneddPort1DropsRxRemoteA | read-only | current | EDD Series card port1 traffic overview:: Drops Rx |
| 1.3.6.1.4.1.4756.20.441.20.1.53 | ColumneddPort1DropsTxRemoteA | read-only | current | EDD Series card port1 traffic overview:: Drops Tx |
| 1.3.6.1.4.1.4756.20.441.20.1.54 | ColumneddPort1FilteredRxRemoteA | read-only | current | EDD Series card port1 traffic overview:: Filtered Rx |
| 1.3.6.1.4.1.4756.20.441.20.1.55 | ColumneddPort2PacketsRxRemoteA | read-only | current | EDD Series card port2 traffic overview:: Packets Rx |
| 1.3.6.1.4.1.4756.20.441.20.1.56 | ColumneddPort2PacketsTxRemoteA | read-only | current | EDD Series card port2 traffic overview:: Packets Tx |
| 1.3.6.1.4.1.4756.20.441.20.1.57 | ColumneddPort2BytesRxRemoteA | read-only | current | EDD Series card port2 traffic overview:: Bytes Rx |
| 1.3.6.1.4.1.4756.20.441.20.1.58 | ColumneddPort2BytesTxRemoteA | read-only | current | EDD Series card port2 traffic overview:: Bytes Tx |
| 1.3.6.1.4.1.4756.20.441.20.1.59 | ColumneddPort2ErrorsRxRemoteA | read-only | current | EDD Series card port2 traffic overview:: Errors Rx |
| 1.3.6.1.4.1.4756.20.441.20.1.60 | ColumneddPort2ErrorsTxRemoteA | read-only | current | EDD Series card port2 traffic overview:: Errors Tx |
| 1.3.6.1.4.1.4756.20.441.20.1.61 | ColumneddPort2DropsRxRemoteA | read-only | current | EDD Series card port2 traffic overview:: Drops Rx |
| 1.3.6.1.4.1.4756.20.441.20.1.62 | ColumneddPort2DropsTxRemoteA | read-only | current | EDD Series card port2 traffic overview:: Drops Tx |
| 1.3.6.1.4.1.4756.20.441.20.1.63 | ColumneddPort2FilteredRxRemoteA | read-only | current | EDD Series card port2 traffic overview:: Filtered Rx |
| 1.3.6.1.4.1.4756.20.441.20.1.64 | ColumneddPort3PacketsRxRemoteA | read-only | current | EDD Series card port3 traffic overview:: Packets Rx |
| 1.3.6.1.4.1.4756.20.441.20.1.65 | ColumneddPort3PacketsTxRemoteA | read-only | current | EDD Series card port3 traffic overview:: Packets Tx |
| 1.3.6.1.4.1.4756.20.441.20.1.66 | ColumneddPort3BytesRxRemoteA | read-only | current | EDD Series card port3 traffic overview:: Bytes Rx |
| 1.3.6.1.4.1.4756.20.441.20.1.67 | ColumneddPort3BytesTxRemoteA | read-only | current | EDD Series card port3 traffic overview:: Bytes Tx |
| 1.3.6.1.4.1.4756.20.441.20.1.68 | ColumneddPort3ErrorsRxRemoteA | read-only | current | EDD Series card port3 traffic overview:: Errors Rx |
| 1.3.6.1.4.1.4756.20.441.20.1.69 | ColumneddPort3ErrorsTxRemoteA | read-only | current | EDD Series card port3 traffic overview:: Errors Tx |
| 1.3.6.1.4.1.4756.20.441.20.1.70 | ColumneddPort3DropsRxRemoteA | read-only | current | EDD Series card port3 traffic overview:: Drops Rx |
| 1.3.6.1.4.1.4756.20.441.20.1.71 | ColumneddPort3DropsTxRemoteA | read-only | current | EDD Series card port3 traffic overview:: Drops Tx |
| 1.3.6.1.4.1.4756.20.441.20.1.72 | ColumneddPort3FilteredRxRemoteA | read-only | current | EDD Series card port3 traffic overview:: Filtered Rx |
| 1.3.6.1.4.1.4756.20.441.20.1.73 | ColumneddPort4PacketsRxRemoteA | read-only | current | EDD Series card port4 traffic overview:: Packets Rx |
| 1.3.6.1.4.1.4756.20.441.20.1.74 | ColumneddPort4PacketsTxRemoteA | read-only | current | EDD Series card port4 traffic overview:: Packets Tx |
| 1.3.6.1.4.1.4756.20.441.20.1.75 | ColumneddPort4BytesRxRemoteA | read-only | current | EDD Series card port4 traffic overview:: Bytes Rx |
| 1.3.6.1.4.1.4756.20.441.20.1.76 | ColumneddPort4BytesTxRemoteA | read-only | current | EDD Series card port4 traffic overview:: Bytes Tx |
| 1.3.6.1.4.1.4756.20.441.20.1.77 | ColumneddPort4ErrorsRxRemoteA | read-only | current | EDD Series card port4 traffic overview:: Errors Rx |
| 1.3.6.1.4.1.4756.20.441.20.1.78 | ColumneddPort4ErrorsTxRemoteA | read-only | current | EDD Series card port4 traffic overview:: Errors Tx |
| 1.3.6.1.4.1.4756.20.441.20.1.79 | ColumneddPort4DropsRxRemoteA | read-only | current | EDD Series card port4 traffic overview:: Drops Rx |
| 1.3.6.1.4.1.4756.20.441.20.1.80 | ColumneddPort4DropsTxRemoteA | read-only | current | EDD Series card port4 traffic overview:: Drops Tx |
| 1.3.6.1.4.1.4756.20.441.20.1.81 | ColumneddPort4FilteredRxRemoteA | read-only | current | EDD Series card port4 traffic overview:: Filtered Rx |
| 1.3.6.1.4.1.4756.20.441.20.1.82 | ColumnedduRingInstanceAddRemoteA | read-write | current | EDD Series card Add a new uRing Instance. Syntax: <Instance ID> <ring|sub|chain> <port east> <port west> Instance ID must be either 1 or 2 port east , the valu… |
| 1.3.6.1.4.1.4756.20.441.20.1.83 | ColumnedduRingInstanceDeleteRemoteA | read-write | current | EDD Series card Delete a uRing Instance. Syntax: <uRing Instance> |
| 1.3.6.1.4.1.4756.20.441.20.1.84 | ColumnedduRingInst1IDRemoteA | read-only | current | EDD Series card u-Ring instance1 ID |
| 1.3.6.1.4.1.4756.20.441.20.1.85 | ColumnedduRingInst1typeRemoteA | read-only | current | EDD Series card u-Ring instance1 type 0: u-Ring 1: Sub-Ring 2: u-Chain |
| 1.3.6.1.4.1.4756.20.441.20.1.86 | ColumnedduRingInst1masterRemoteA | read-write | current | EDD Series card u-Ring instance1 master 0: No 1: Yes |
| 1.3.6.1.4.1.4756.20.441.20.1.87 | ColumnedduRingInst1EastPortRemoteA | read-only | current | EDD Series card u-Ring instance1 east port |
| 1.3.6.1.4.1.4756.20.441.20.1.88 | ColumnedduRingInst1EastEdgeRemoteA | read-write | current | EDD Series card u-Ring instance1 east edge 0: No 1: Yes |
| 1.3.6.1.4.1.4756.20.441.20.1.89 | ColumnedduRingInst1WestPortRemoteA | read-only | current | EDD Series card u-Ring instance1 west port |
| 1.3.6.1.4.1.4756.20.441.20.1.90 | ColumnedduRingInst1WestEdgeRemoteA | read-write | current | EDD Series card u-Ring instance1 west edge 0: No 1: Yes |
| 1.3.6.1.4.1.4756.20.441.20.1.91 | ColumnedduRingInst2IDRemoteA | read-only | current | EDD Series card u-Ring instance2 ID |
| 1.3.6.1.4.1.4756.20.441.20.1.92 | ColumnedduRingInst2typeRemoteA | read-only | current | EDD Series card u-Ring instance2 type 0: u-Ring 1: Sub-Ring 2: u-Chain |
| 1.3.6.1.4.1.4756.20.441.20.1.93 | ColumnedduRingInst2masterRemoteA | read-write | current | EDD Series card u-Ring instance2 master 0: No 1: Yes |
| 1.3.6.1.4.1.4756.20.441.20.1.94 | ColumnedduRingInst2EastPortRemoteA | read-only | current | EDD Series card u-Ring instance2 east port |
| 1.3.6.1.4.1.4756.20.441.20.1.95 | ColumnedduRingInst2EastEdgeRemoteA | read-write | current | EDD Series card u-Ring instance2 east edge 0: No 1: Yes |
| 1.3.6.1.4.1.4756.20.441.20.1.96 | ColumnedduRingInst2WestPortRemoteA | read-only | current | EDD Series card u-Ring instance2 west port |
| 1.3.6.1.4.1.4756.20.441.20.1.97 | ColumnedduRingInst2WestEdgeRemoteA | read-write | current | EDD Series card u-Ring instance2 west edge 0: No 1: Yes |
| 1.3.6.1.4.1.4756.20.441.20.1.98 | ColumnedduRingInst1IDstsRemoteA | read-only | current | EDD Series card u-Ring Instance1 ID status |
| 1.3.6.1.4.1.4756.20.441.20.1.99 | ColumnedduRingInst1typestsRemoteA | read-only | current | EDD Series card u-Ring Type status |
| 1.3.6.1.4.1.4756.20.441.20.1.100 | ColumnedduRingInst1rolestsRemoteA | read-only | current | EDD Series card u-Ring Role status |
| 1.3.6.1.4.1.4756.20.441.20.1.101 | ColumnedduRingInst1EastPortstsRemoteA | read-only | current | EDD Series card u-Ring East port status |
| 1.3.6.1.4.1.4756.20.441.20.1.102 | ColumnedduRingInst1EaststsRemoteA | read-only | current | EDD Series card u-Ring East status |
| 1.3.6.1.4.1.4756.20.441.20.1.103 | ColumnedduRingInst1EastEdgestsRemoteA | read-only | current | EDD Series card u-Ring East edge status |
| 1.3.6.1.4.1.4756.20.441.20.1.104 | ColumnedduRingInst1WestPortstsRemoteA | read-only | current | EDD Series card u-Ring West edge status |
| 1.3.6.1.4.1.4756.20.441.20.1.105 | ColumnedduRingInst1WeststsRemoteA | read-only | current | EDD Series card u-Ring West status |
| 1.3.6.1.4.1.4756.20.441.20.1.106 | ColumnedduRingInst1WestEdgestsRemoteA | read-only | current | EDD Series card u-Ring West status |
| 1.3.6.1.4.1.4756.20.441.20.1.107 | ColumnedduRingInst1healthystsRemoteA | read-only | current | EDD Series card u-Ring healthy status None Fine Fault |
| 1.3.6.1.4.1.4756.20.441.20.1.108 | ColumnedduRingInst2IDstsRemoteA | read-only | current | EDD Series card u-Ring Instance2 ID status |
| 1.3.6.1.4.1.4756.20.441.20.1.109 | ColumnedduRingInst2typestsRemoteA | read-only | current | EDD Series card u-Ring Type status |
| 1.3.6.1.4.1.4756.20.441.20.1.110 | ColumnedduRingInst2rolestsRemoteA | read-only | current | EDD Series card u-Ring Role status |
| 1.3.6.1.4.1.4756.20.441.20.1.111 | ColumnedduRingInst2EastPortstsRemoteA | read-only | current | EDD Series card u-Ring East port status |
| 1.3.6.1.4.1.4756.20.441.20.1.112 | ColumnedduRingInst2EaststsRemoteA | read-only | current | EDD Series card u-Ring East status |
| 1.3.6.1.4.1.4756.20.441.20.1.113 | ColumnedduRingInst2EastEdgestsRemoteA | read-only | current | EDD Series card u-Ring East edge status |
| 1.3.6.1.4.1.4756.20.441.20.1.114 | ColumnedduRingInst2WestPortstsRemoteA | read-only | current | EDD Series card u-Ring West edge status |
| 1.3.6.1.4.1.4756.20.441.20.1.115 | ColumnedduRingInst2WeststsRemoteA | read-only | current | EDD Series card u-Ring West status |
| 1.3.6.1.4.1.4756.20.441.20.1.116 | ColumnedduRingInst2WestEdgestsRemoteA | read-only | current | EDD Series card u-Ring West status |
| 1.3.6.1.4.1.4756.20.441.20.1.117 | ColumnedduRingInst2healthystsRemoteA | read-only | current | EDD Series card u-Ring healthy status None Fine Fault |
| 1.3.6.1.4.1.4756.20.441.20.1.118 | ColumneddDeviceActiveRemoteA | read-only | current | EDD Series card u-Ring device active 0: Disable 1: Enable |
| 1.3.6.1.4.1.4756.20.441.20.1.119 | ColumneddFx1DDRemoteA | read-only | current | EDD Series card fiber port Digital Diagnostic function: 0:No 1:Yes |
| 1.3.6.1.4.1.4756.20.441.20.1.120 | ColumneddFx1DDVendorRemoteA | read-only | current | EDD Series card fiber port D/D information: Vendor name |
| 1.3.6.1.4.1.4756.20.441.20.1.121 | ColumneddFx1DDPartNoRemoteA | read-only | current | EDD Series card fiber port D/D information: Vendor part number |
| 1.3.6.1.4.1.4756.20.441.20.1.122 | ColumneddFx1DDFiberTypeRemoteA | read-only | current | EDD Series card fiber port D/D information: Fiber Type |
| 1.3.6.1.4.1.4756.20.441.20.1.123 | ColumneddFx1DDWaveLenRemoteA | read-only | current | EDD Series card fiber port D/D information: Wave length |
| 1.3.6.1.4.1.4756.20.441.20.1.124 | ColumneddFx1DDWaveLen2RemoteA | read-only | current | EDD Series card fiber port D/D information: Wave length 2 |
| 1.3.6.1.4.1.4756.20.441.20.1.125 | ColumneddFx1DDLinkLenRemoteA | read-only | current | EDD Series card fiber port D/D information: Link length |
| 1.3.6.1.4.1.4756.20.441.20.1.126 | ColumneddFx1DDLenUnitRemoteA | read-only | current | EDD Series card fiber port D/D information: Length Unit |
| 1.3.6.1.4.1.4756.20.441.20.1.127 | ColumneddFx1DDStatusRemoteA | read-only | current | EDD Series card fiber port D/D information: Status Support |
| 1.3.6.1.4.1.4756.20.441.20.1.128 | ColumneddFx1DDRxSensRemoteA | read-only | current | EDD Series card fiber port D/D information: Rx Sensitivity |
| 1.3.6.1.4.1.4756.20.441.20.1.129 | ColumneddFx1DDTxPWRRemoteA | read-only | current | EDD Series card fiber port D/D information: Tx power |
| 1.3.6.1.4.1.4756.20.441.20.1.130 | ColumneddFx1DDRxPWRRemoteA | read-only | current | EDD Series card fiber port D/D information: Rx power |
| 1.3.6.1.4.1.4756.20.441.20.1.131 | ColumneddFx1DDTempRemoteA | read-only | current | EDD Series card fiber port D/D information: Temperature in degree C |
| 1.3.6.1.4.1.4756.20.441.20.1.132 | ColumneddFx1DDPWRMarginRemoteA | read-only | current | EDD Series card fiber port D/D information: Power margin |
| 1.3.6.1.4.1.4756.20.441.20.1.133 | ColumneddFx1DDPWRLossRemoteA | read-only | current | EDD Series card fiber port D/D information: Power loss |
| 1.3.6.1.4.1.4756.20.441.20.1.134 | ColumneddFx2DDRemoteA | read-only | current | EDD Series card fiber2 Digital Diagnostic function: 0:NO 1:Yes |
| 1.3.6.1.4.1.4756.20.441.20.1.135 | ColumneddFx2DDVendorRemoteA | read-only | current | EDD Series card fiber2 D/D information: Vendor name |
| 1.3.6.1.4.1.4756.20.441.20.1.136 | ColumneddFx2DDPartNoRemoteA | read-only | current | EDD Series card fiber2 D/D information: Vendor part number |
| 1.3.6.1.4.1.4756.20.441.20.1.137 | ColumneddFx2DDFiberTypeRemoteA | read-only | current | EDD Series card fiber2 D/D information: Fiber Type |
| 1.3.6.1.4.1.4756.20.441.20.1.138 | ColumneddFx2DDWaveLenRemoteA | read-only | current | EDD Series card fiber2 D/D information: Wave length 1 |
| 1.3.6.1.4.1.4756.20.441.20.1.139 | ColumneddFx2DDWaveLen2RemoteA | read-only | current | EDD Series card fiber2 D/D information: Wave length 2 |
| 1.3.6.1.4.1.4756.20.441.20.1.140 | ColumneddFx2DDLinkLenRemoteA | read-only | current | EDD Series card fiber2 D/D information: Link length |
| 1.3.6.1.4.1.4756.20.441.20.1.141 | ColumneddFx2DDLenUnitRemoteA | read-only | current | EDD Series card fiber2 D/D information: Length Unit |
| 1.3.6.1.4.1.4756.20.441.20.1.142 | ColumneddFx2DDStatusRemoteA | read-only | current | EDD Series card fiber2 D/D information: Status Support |
| 1.3.6.1.4.1.4756.20.441.20.1.143 | ColumneddFx2DDRxSensRemoteA | read-only | current | EDD Series card fiber2 D/D information: Rx Sensitivity |
| 1.3.6.1.4.1.4756.20.441.20.1.144 | ColumneddFx2DDTxPWRRemoteA | read-only | current | EDD Series card fiber2 D/D information: Tx power |
| 1.3.6.1.4.1.4756.20.441.20.1.145 | ColumneddFx2DDRxPWRRemoteA | read-only | current | EDD Series card fiber2 D/D information: Rx power |
| 1.3.6.1.4.1.4756.20.441.20.1.146 | ColumneddFx2DDTempRemoteA | read-only | current | EDD Series card fiber2 D/D information: Temperature in degree C |
| 1.3.6.1.4.1.4756.20.441.20.1.147 | ColumneddFx2DDPWRMarginRemoteA | read-only | current | EDD Series card fiber2 D/D information: Power margin |
| 1.3.6.1.4.1.4756.20.441.20.1.148 | ColumneddFx2DDPWRLossRemoteA | read-only | current | EDD Series card fiber2 D/D information: Power loss |
| 1.3.6.1.4.1.4756.20.441.20.1.149 | ColumneddFx3DDRemoteA | read-only | current | EDD Series card fiber3 Digital Diagnostic function: 0:NO 1:Yes |
| 1.3.6.1.4.1.4756.20.441.20.1.150 | ColumneddFx3DDVendorRemoteA | read-only | current | EDD Series card fiber3 D/D information: Vendor name |
| 1.3.6.1.4.1.4756.20.441.20.1.151 | ColumneddFx3DDPartNoRemoteA | read-only | current | EDD Series card fiber32 D/D information: Vendor part number |
| 1.3.6.1.4.1.4756.20.441.20.1.152 | ColumneddFx3DDFiberTypeRemoteA | read-only | current | EDD Series card fiber3 D/D information: Fiber Type |
| 1.3.6.1.4.1.4756.20.441.20.1.153 | ColumneddFx3DDWaveLenRemoteA | read-only | current | EDD Series card fiber3 D/D information: Wave length 1 |
| 1.3.6.1.4.1.4756.20.441.20.1.154 | ColumneddFx3DDWaveLen2RemoteA | read-only | current | EDD Series card fiber3 D/D information: Wave length 2 |
| 1.3.6.1.4.1.4756.20.441.20.1.155 | ColumneddFx3DDLinkLenRemoteA | read-only | current | EDD Series card fiber3 D/D information: Link length |
| 1.3.6.1.4.1.4756.20.441.20.1.156 | ColumneddFx3DDLenUnitRemoteA | read-only | current | EDD Series card fiber3 D/D information: Length Unit |
| 1.3.6.1.4.1.4756.20.441.20.1.157 | ColumneddFx3DDStatusRemoteA | read-only | current | EDD Series card fiber3 D/D information: Status Support |
| 1.3.6.1.4.1.4756.20.441.20.1.158 | ColumneddFx3DDRxSensRemoteA | read-only | current | EDD Series card fiber3 D/D information: Rx Sensitivity |
| 1.3.6.1.4.1.4756.20.441.20.1.159 | ColumneddFx3DDTxPWRRemoteA | read-only | current | EDD Series card fiber3 D/D information: Tx power |
| 1.3.6.1.4.1.4756.20.441.20.1.160 | ColumneddFx3DDRxPWRRemoteA | read-only | current | EDD Series card fiber3 D/D information: Rx power |
| 1.3.6.1.4.1.4756.20.441.20.1.161 | ColumneddFx3DDTempRemoteA | read-only | current | EDD Series card fiber3 D/D information: Temperature in degree C |
| 1.3.6.1.4.1.4756.20.441.20.1.162 | ColumneddFx3DDPWRMarginRemoteA | read-only | current | EDD Series card fiber3 D/D information: Power margin |
| 1.3.6.1.4.1.4756.20.441.20.1.163 | ColumneddFx3DDPWRLossRemoteA | read-only | current | EDD Series card fiber3 D/D information: Power loss |
| 1.3.6.1.4.1.4756.20.441.20.1.164 | ColumneddTestRemoteA | read-only | current | EDD Series card test led sts: 0: Off 1: On |
| 1.3.6.1.4.1.4756.20.441.20.1.165 | ColumneddClearPortCounterRemoteA | read-write | current | EDD Series card clear port counter: 0: Off 1: Action |
| 1.3.6.1.4.1.4756.20.441.20.1.166 | ColumneddAggrSourceMACAddrRemoteA | read-write | current | EDD Series card Aggregation Mode Configuration: Source MAC Address 0: No 1: Yes |
| 1.3.6.1.4.1.4756.20.441.20.1.167 | ColumneddAggrDestinationMACAddrRemoteA | read-write | current | EDD Series card Aggregation Mode Configuration: Destination MAC Address 0: No 1: Yes |
| 1.3.6.1.4.1.4756.20.441.20.1.168 | ColumneddAggrIPAddrRemoteA | read-write | current | EDD Series card Aggregation Mode Configuration: IP Address 0: No 1: Yes |
| 1.3.6.1.4.1.4756.20.441.20.1.169 | ColumneddAggrTCPUDPPortNumRemoteA | read-write | current | EDD Series card Aggregation Mode Configuration: TCP/UDP Port Number 0: No 1: Yes |
| 1.3.6.1.4.1.4756.20.441.20.1.170 | ColumneddAggrGroupPort1ConfRemoteA | read-write | current | EDD Series card Aggregation Group Port1 Configuration: 0: Normal 1: ID1 2: ID2 |
| 1.3.6.1.4.1.4756.20.441.20.1.171 | ColumneddAggrGroupPort2ConfRemoteA | read-write | current | EDD Series card Aggregation Group Port2 Configuration: 0: Normal 1: ID1 2: ID2 |
| 1.3.6.1.4.1.4756.20.441.20.1.172 | ColumneddAggrGroupPort3ConfRemoteA | read-write | current | EDD Series card Aggregation Group Port3 Configuration: 0: Normal 1: ID1 2: ID2 |
| 1.3.6.1.4.1.4756.20.441.20.1.173 | ColumneddAggrGroupPort4ConfRemoteA | read-write | current | EDD Series card Aggregation Group Port4 Configuration: 0: Normal 1: ID1 2: ID2 |
| 1.3.6.1.4.1.4756.20.441.20.1.174 | ColumneddPort1LACPEnabledRemoteA | read-write | current | EDD Series card Port1 LACP Enabled: 0: No 1: Yes |
| 1.3.6.1.4.1.4756.20.441.20.1.175 | ColumneddPort1LACPKEYRemoteA | read-write | current | EDD Series card Port1 LACP Key value: The Key value incurred by the port, range 0-65535.The value of 0 means auto. |
| 1.3.6.1.4.1.4756.20.441.20.1.176 | ColumneddPort1LACPRoleRemoteA | read-write | current | EDD Series card Port1 LACP Role: 0: Passive 1: Active |
| 1.3.6.1.4.1.4756.20.441.20.1.177 | ColumneddPort1LACPTimeOutRemoteA | read-write | current | EDD Series card Port1 LACP Time out: 0: Slow 1: Fast |
| 1.3.6.1.4.1.4756.20.441.20.1.178 | ColumneddPort1LACPPrioRemoteA | read-write | current | EDD Series card Port1 LACP priority: The Key value incurred by the port, range 1-65535. |
| 1.3.6.1.4.1.4756.20.441.20.1.179 | ColumneddPort2LACPEnabledRemoteA | read-write | current | EDD Series card Port2 LACP Enabled: 0: No 1: Yes |
| 1.3.6.1.4.1.4756.20.441.20.1.180 | ColumneddPort2LACPKEYRemoteA | read-write | current | EDD Series card Port2 LACP Key value: The Key value incurred by the port, range 0-65535.The value of 0 means auto. |
| 1.3.6.1.4.1.4756.20.441.20.1.181 | ColumneddPort2LACPRoleRemoteA | read-write | current | EDD Series card Port2 LACP Role: 0: Passive 1: Active |
| 1.3.6.1.4.1.4756.20.441.20.1.182 | ColumneddPort2LACPTimeOutRemoteA | read-write | current | EDD Series card Port2 LACP Time out: 0: Slow 1: Fast |
| 1.3.6.1.4.1.4756.20.441.20.1.183 | ColumneddPort2LACPPrioRemoteA | read-write | current | EDD Series card Port2 LACP priority: The Key value incurred by the port, range 1-65535. |
| 1.3.6.1.4.1.4756.20.441.20.1.184 | ColumneddPort3LACPEnabledRemoteA | read-write | current | EDD Series card Port3 LACP Enabled: 0: No 1: Yes |
| 1.3.6.1.4.1.4756.20.441.20.1.185 | ColumneddPort3LACPKEYRemoteA | read-write | current | EDD Series card Port3 LACP Key value: The Key value incurred by the port, range 0-65535.The value of 0 means auto. |
| 1.3.6.1.4.1.4756.20.441.20.1.186 | ColumneddPort3LACPRoleRemoteA | read-write | current | EDD Series card Port3 LACP Role: 0: Passive 1: Active |
| 1.3.6.1.4.1.4756.20.441.20.1.187 | ColumneddPort3LACPTimeOutRemoteA | read-write | current | EDD Series card Port3 LACP Time out: 0: Slow 1: Fast |
| 1.3.6.1.4.1.4756.20.441.20.1.188 | ColumneddPort3LACPPrioRemoteA | read-write | current | EDD Series card Port3 LACP priority: The Key value incurred by the port, range 1-65535. |
| 1.3.6.1.4.1.4756.20.441.20.1.189 | ColumneddPort4LACPEnabledRemoteA | read-write | current | EDD Series card Port4 LACP Enabled: 0: No 1: Yes |
| 1.3.6.1.4.1.4756.20.441.20.1.190 | ColumneddPort4LACPKEYRemoteA | read-write | current | EDD Series card Port4 LACP Key value: The Key value incurred by the port, range 0-65535.The value of 0 means auto. |
| 1.3.6.1.4.1.4756.20.441.20.1.191 | ColumneddPort4LACPRoleRemoteA | read-write | current | EDD Series card Port4 LACP Role: 0: Passive 1: Active |
| 1.3.6.1.4.1.4756.20.441.20.1.192 | ColumneddPort4LACPTimeOutRemoteA | read-write | current | EDD Series card Port4 LACP Time out: 0: Slow 1: Fast |
| 1.3.6.1.4.1.4756.20.441.20.1.193 | ColumneddPort4LACPPrioRemoteA | read-write | current | EDD Series card Port4 LACP priority: The Key value incurred by the port, range 1-65535. |
| 1.3.6.1.4.1.4756.20.441.20.1.194 | ColumneddPort1LACPstsRemoteA | read-only | current | EDD Series card Port1 LACP status: 0: No 1: Yes 2: Standby |
| 1.3.6.1.4.1.4756.20.441.20.1.195 | ColumneddPort1LACPKEYstsRemoteA | read-only | current | EDD Series card Port1 LACP status: Key |
| 1.3.6.1.4.1.4756.20.441.20.1.196 | ColumneddPort1LACPAggrIDstsRemoteA | read-only | current | EDD Series card Port1 LACP status: Aggr ID |
| 1.3.6.1.4.1.4756.20.441.20.1.197 | ColumneddPort1LACPParnterSysIDstsRemoteA | read-only | current | EDD Series card Port1 LACP status: Parnter System ID |
| 1.3.6.1.4.1.4756.20.441.20.1.198 | ColumneddPort1LACPParnterPortstsRemoteA | read-only | current | EDD Series card Port1 LACP status: Parnter Port Status |
| 1.3.6.1.4.1.4756.20.441.20.1.199 | ColumneddPort1LACPParnterProistsRemoteA | read-only | current | EDD Series card Port1 LACP status: Parnter Priority |
| 1.3.6.1.4.1.4756.20.441.20.1.200 | ColumneddPort2LACPstsRemoteA | read-only | current | EDD Series card Port2 LACP status: 0: No 1: Yes 2: Standby |
| 1.3.6.1.4.1.4756.20.441.20.1.201 | ColumneddPort2LACPKEYstsRemoteA | read-only | current | EDD Series card Port2 LACP status: Key |
| 1.3.6.1.4.1.4756.20.441.20.1.202 | ColumneddPort2LACPAggrIDstsRemoteA | read-only | current | EDD Series card Port2 LACP status: Aggr ID |
| 1.3.6.1.4.1.4756.20.441.20.1.203 | ColumneddPort2LACPParnterSysIDstsRemoteA | read-only | current | EDD Series card Port2 LACP status: Parnter System ID |
| 1.3.6.1.4.1.4756.20.441.20.1.204 | ColumneddPort2LACPParnterPortstsRemoteA | read-only | current | EDD Series card Port2 LACP status: Parnter Port Status |
| 1.3.6.1.4.1.4756.20.441.20.1.205 | ColumneddPort2LACPParnterProistsRemoteA | read-only | current | EDD Series card Port2 LACP status: Parnter Priority |
| 1.3.6.1.4.1.4756.20.441.20.1.206 | ColumneddPort3LACPstsRemoteA | read-only | current | EDD Series card Port3 LACP status: 0: No 1: Yes 2: Standby |
| 1.3.6.1.4.1.4756.20.441.20.1.207 | ColumneddPort3LACPKEYstsRemoteA | read-only | current | EDD Series card Port3 LACP status: Key |
| 1.3.6.1.4.1.4756.20.441.20.1.208 | ColumneddPort3LACPAggrIDstsRemoteA | read-only | current | EDD Series card Port3 LACP status: Aggr ID |
| 1.3.6.1.4.1.4756.20.441.20.1.209 | ColumneddPort3LACPParnterSysIDstsRemoteA | read-only | current | EDD Series card Port3 LACP status: Parnter System ID |
| 1.3.6.1.4.1.4756.20.441.20.1.210 | ColumneddPort3LACPParnterPortstsRemoteA | read-only | current | EDD Series card Port3 LACP status: Parnter Port Status |
| 1.3.6.1.4.1.4756.20.441.20.1.211 | ColumneddPort3LACPParnterProistsRemoteA | read-only | current | EDD Series card Port3 LACP status: Parnter Priority |
| 1.3.6.1.4.1.4756.20.441.20.1.212 | ColumneddPort4LACPstsRemoteA | read-only | current | EDD Series card Port4 LACP status: 0: No 1: Yes 2: Standby |
| 1.3.6.1.4.1.4756.20.441.20.1.213 | ColumneddPort4LACPKEYstsRemoteA | read-only | current | EDD Series card Port4 LACP status: Key |
| 1.3.6.1.4.1.4756.20.441.20.1.214 | ColumneddPort4LACPAggrIDstsRemoteA | read-only | current | EDD Series card Port4 LACP status: Aggr ID |
| 1.3.6.1.4.1.4756.20.441.20.1.215 | ColumneddPort4LACPParnterSysIDstsRemoteA | read-only | current | EDD Series card Port4 LACP status: Parnter System ID |
| 1.3.6.1.4.1.4756.20.441.20.1.216 | ColumneddPort4LACPParnterPortstsRemoteA | read-only | current | EDD Series card Port4 LACP status: Parnter Port Status |
| 1.3.6.1.4.1.4756.20.441.20.1.217 | ColumneddPort4LACPParnterProistsRemoteA | read-only | current | EDD Series card Port4 LACP status: Parnter Priority |
| 1.3.6.1.4.1.4756.20.441.20.1.218 | ColumneddOAMPort1EnableRemoteA | read-write | current | EDD Series card Port1 OAM: 0: Off 1: On |
| 1.3.6.1.4.1.4756.20.441.20.1.219 | ColumneddOAMPort1ModeRemoteA | read-write | current | EDD Series card Port1 OAM: 0: Passive 1: Active |
| 1.3.6.1.4.1.4756.20.441.20.1.220 | ColumneddOAMPort1LoopBackRemoteA | read-write | current | EDD Series card Port1 OAM LoopBack: 0: Off 1: On |
| 1.3.6.1.4.1.4756.20.441.20.1.221 | ColumneddOAMPort1LinkMonitorRemoteA | read-write | current | EDD Series card Port1 OAM Link Monitor: 0: Off 1: On |
| 1.3.6.1.4.1.4756.20.441.20.1.222 | ColumneddOAMPort1MIBRetrievalRemoteA | read-write | current | EDD Series card Port1 OAM MIB Retrieval: 0: Off 1: On |
| 1.3.6.1.4.1.4756.20.441.20.1.223 | ColumneddOAMPort1LoopBackOPRemoteA | read-only | current | EDD Series card Port1 OAM LoopBack operation: 0: Off 1: On |
| 1.3.6.1.4.1.4756.20.441.20.1.224 | ColumneddOAMPort2EnableRemoteA | read-write | current | EDD Series card Port2 OAM: 0: Off 1: On |
| 1.3.6.1.4.1.4756.20.441.20.1.225 | ColumneddOAMPort2ModeRemoteA | read-write | current | EDD Series card Port2 OAM: 0: Passive 1: Active |
| 1.3.6.1.4.1.4756.20.441.20.1.226 | ColumneddOAMPort2LoopBackRemoteA | read-write | current | EDD Series card Port2 OAM LoopBack: 0: Off 1: On |
| 1.3.6.1.4.1.4756.20.441.20.1.227 | ColumneddOAMPort2LinkMonitorRemoteA | read-write | current | EDD Series card Port2 OAM Link Monitor: 0: Off 1: On |
| 1.3.6.1.4.1.4756.20.441.20.1.228 | ColumneddOAMPort2MIBRetrievalRemoteA | read-write | current | EDD Series card Port2 OAM MIB Retrieval: 0: Off 1: On |
| 1.3.6.1.4.1.4756.20.441.20.1.229 | ColumneddOAMPort2LoopBackOPRemoteA | read-only | current | EDD Series card Port2 OAM LoopBack operation: 0: Off 1: On |
| 1.3.6.1.4.1.4756.20.441.20.1.230 | ColumneddOAMPort3EnableRemoteA | read-write | current | EDD Series card Port3 OAM: 0: Off 1: On |
| 1.3.6.1.4.1.4756.20.441.20.1.231 | ColumneddOAMPort3ModeRemoteA | read-write | current | EDD Series card Port3 OAM: 0: Passive 1: Active |
| 1.3.6.1.4.1.4756.20.441.20.1.232 | ColumneddOAMPort3LoopBackRemoteA | read-write | current | EDD Series card Port3 OAM: 0: Off 1: On |
| 1.3.6.1.4.1.4756.20.441.20.1.233 | ColumneddOAMPort3LinkMonitorRemoteA | read-write | current | EDD Series card Port3 OAM Link Monitor: 0: Off 1: On |
| 1.3.6.1.4.1.4756.20.441.20.1.234 | ColumneddOAMPort3MIBRetrievalRemoteA | read-write | current | EDD Series card Port3 OAM MIB Retrieval: 0: Off 1: On |
| 1.3.6.1.4.1.4756.20.441.20.1.235 | ColumneddOAMPort3LoopBackOPRemoteA | read-only | current | EDD Series card Port3 OAM LoopBack operation: 0: Disable 1: Enable |
| 1.3.6.1.4.1.4756.20.441.20.1.236 | ColumneddOAMPort4EnableRemoteA | read-write | current | EDD Series card Port4 OAM: 0: Off 1: On |
| 1.3.6.1.4.1.4756.20.441.20.1.237 | ColumneddOAMPort4ModeRemoteA | read-write | current | EDD Series card Port4 OAM: 0: Passive 1: Active |
| 1.3.6.1.4.1.4756.20.441.20.1.238 | ColumneddOAMPort4LoopBackRemoteA | read-write | current | EDD Series card Port4 OAM: 0: Off 1: On |
| 1.3.6.1.4.1.4756.20.441.20.1.239 | ColumneddOAMPort4LinkMonitorRemoteA | read-write | current | EDD Series card Port4 OAM Link Monitor: 0: Off 1: On |
| 1.3.6.1.4.1.4756.20.441.20.1.240 | ColumneddOAMPort4MIBRetrievalRemoteA | read-write | current | EDD Series card Port4 OAM MIB Retrieval: 0: Off 1: On |
| 1.3.6.1.4.1.4756.20.441.20.1.241 | ColumneddOAMPort4LoopBackOPRemoteA | read-only | current | EDD Series card Port4 OAM LoopBack operation: 0: On 1: Off |
| 1.3.6.1.4.1.4756.20.441.20.1.242 | ColumneddPort1EFEErrorWindowRemoteA | read-write | current | EDD Series card Port1 Link Event Configuration: Error Frame Event - Error Window |
| 1.3.6.1.4.1.4756.20.441.20.1.243 | ColumneddPort1EFEErrorThresholdRemoteA | read-write | current | EDD Series card Port1 Link Event Configuration: Error Frame Event - Error Threshold |
| 1.3.6.1.4.1.4756.20.441.20.1.244 | ColumneddPort1SPEEErrorWindowRemoteA | read-write | current | EDD Series card Port1 Link Event Configuration: Symbol Period Error Event - Error Window |
| 1.3.6.1.4.1.4756.20.441.20.1.245 | ColumneddPort1SPEEErrorThresholdRemoteA | read-write | current | EDD Series card Port1 Link Event Configuration: Symbol Period Error Event - Error Threshold |
| 1.3.6.1.4.1.4756.20.441.20.1.246 | ColumneddPort1SSEErrorWindowRemoteA | read-write | current | EDD Series card Port1 Link Event Configuration: Seconds Summary Event - Error Window |
| 1.3.6.1.4.1.4756.20.441.20.1.247 | ColumneddPort1SSEErrorThresholdRemoteA | read-write | current | EDD Series card Port1 Link Event Configuration: Seconds Summary Event - Error Threshold |
| 1.3.6.1.4.1.4756.20.441.20.1.248 | ColumneddPort2EFEErrorWindowRemoteA | read-write | current | EDD Series card Port2 Link Event Configuration: Error Frame Event - Error Window |
| 1.3.6.1.4.1.4756.20.441.20.1.249 | ColumneddPort2EFEErrorThresholdRemoteA | read-write | current | EDD Series card Port2 Link Event Configuration: Error Frame Event - Error Threshold |
| 1.3.6.1.4.1.4756.20.441.20.1.250 | ColumneddPort2SPEEErrorWindowRemoteA | read-write | current | EDD Series card Port2 Link Event Configuration: Symbol Period Error Event - Error Window |
| 1.3.6.1.4.1.4756.20.441.20.1.251 | ColumneddPort2SPEEErrorThresholdRemoteA | read-write | current | EDD Series card Port2 Link Event Configuration: Symbol Period Error Event - Error Threshold |
| 1.3.6.1.4.1.4756.20.441.20.1.252 | ColumneddPort2SSEErrorWindowRemoteA | read-write | current | EDD Series card Port2 Link Event Configuration: Seconds Summary Event - Error Window |
| 1.3.6.1.4.1.4756.20.441.20.1.253 | ColumneddPort2SSEErrorThresholdRemoteA | read-write | current | EDD Series card Port2 Link Event Configuration: Seconds Summary Event - Error Threshold |
| 1.3.6.1.4.1.4756.20.441.20.1.254 | ColumneddPort3EFEErrorWindowRemoteA | read-write | current | EDD Series card Port3 Link Event Configuration: Error Frame Event - Error Window |
| 1.3.6.1.4.1.4756.20.441.20.1.255 | ColumneddPort3EFEErrorThresholdRemoteA | read-write | current | EDD Series card Port3 Link Event Configuration: Error Frame Event - Error Threshold |
| 1.3.6.1.4.1.4756.20.441.20.1.256 | ColumneddPort3SPEEErrorWindowRemoteA | read-write | current | EDD Series card Port3 Link Event Configuration: Symbol Period Error Event - Error Window |
| 1.3.6.1.4.1.4756.20.441.20.1.257 | ColumneddPort3SPEEErrorThresholdRemoteA | read-write | current | EDD Series card Port3 Link Event Configuration: Symbol Period Error Event - Error Threshold |
| 1.3.6.1.4.1.4756.20.441.20.1.258 | ColumneddPort3SSEErrorWindowRemoteA | read-write | current | EDD Series card Port3 Link Event Configuration: Seconds Summary Event - Error Window |
| 1.3.6.1.4.1.4756.20.441.20.1.259 | ColumneddPort3SSEErrorThresholdRemoteA | read-write | current | EDD Series card Port3 Link Event Configuration: Seconds Summary Event - Error Threshold |
| 1.3.6.1.4.1.4756.20.441.20.1.260 | ColumneddPort4EFEErrorWindowRemoteA | read-write | current | EDD Series card Port4 Link Event Configuration: Error Frame Event - Error Window |
| 1.3.6.1.4.1.4756.20.441.20.1.261 | ColumneddPort4EFEErrorThresholdRemoteA | read-write | current | EDD Series card Port4 Link Event Configuration: Error Frame Event - Error Threshold |
| 1.3.6.1.4.1.4756.20.441.20.1.262 | ColumneddPort4SPEEErrorWindowRemoteA | read-write | current | EDD Series card Port4 Link Event Configuration: Symbol Period Error Event - Error Window |
| 1.3.6.1.4.1.4756.20.441.20.1.263 | ColumneddPort4SPEEErrorThresholdRemoteA | read-write | current | EDD Series card Port4 Link Event Configuration: Symbol Period Error Event - Error Threshold |
| 1.3.6.1.4.1.4756.20.441.20.1.264 | ColumneddPort4SSEErrorWindowRemoteA | read-write | current | EDD Series card Port4 Link Event Configuration: Seconds Summary Event - Error Window |
| 1.3.6.1.4.1.4756.20.441.20.1.265 | ColumneddPort4SSEErrorThresholdRemoteA | read-write | current | EDD Series card Port4 Link Event Configuration: Seconds Summary Event - Error Threshold |
| 1.3.6.1.4.1.4756.20.441.20.1.266 | ColumneddPort1RxOAMInfoPDURemoteA | read-only | current | EDD Series card Port1 Detailed Link OAM Statistics: Rx OAM Information PDU's |
| 1.3.6.1.4.1.4756.20.441.20.1.267 | ColumneddPort1RxUniqueErrorEventRemoteA | read-only | current | EDD Series card Port1 Detailed Link OAM Statistics: Rx Unique Error Event Notificatio |
| 1.3.6.1.4.1.4756.20.441.20.1.268 | ColumneddPort1RxDuplicateErrorEventRemoteA | read-only | current | EDD Series card Port1 Detailed Link OAM Statistics: Rx Duplicate Error Event Notification |
| 1.3.6.1.4.1.4756.20.441.20.1.269 | ColumneddPort1RxLoopBackControlRemoteA | read-only | current | EDD Series card Port1 Detailed Link OAM Statistics: Rx Loopback Control |
| 1.3.6.1.4.1.4756.20.441.20.1.270 | ColumneddPort1RxVariableRequestRemoteA | read-only | current | EDD Series card Port1 Detailed Link OAM Statistics: Rx Variable Request |
| 1.3.6.1.4.1.4756.20.441.20.1.271 | ColumneddPort1RxVariableResponseRemoteA | read-only | current | EDD Series card Port1 Detailed Link OAM Statistics: Rx Variable Response |
| 1.3.6.1.4.1.4756.20.441.20.1.272 | ColumneddPort1RxOrgSpecificPDURemoteA | read-only | current | EDD Series card Port1 Detailed Link OAM Statistics: Rx Org Specific PDU's |
| 1.3.6.1.4.1.4756.20.441.20.1.273 | ColumneddPort1RxUnsupportedCodesRemoteA | read-only | current | EDD Series card Port1 Detailed Link OAM Statistics: Rx Unsupported Codes |
| 1.3.6.1.4.1.4756.20.441.20.1.274 | ColumneddPort1RxLinkFaultPDURemoteA | read-only | current | EDD Series card Port1 Detailed Link OAM Statistics: Rx Link Fault PDU's |
| 1.3.6.1.4.1.4756.20.441.20.1.275 | ColumneddPort1RxDyingGaspRemoteA | read-only | current | EDD Series card Port1 Detailed Link OAM Statistics: Rx Dying Gasp |
| 1.3.6.1.4.1.4756.20.441.20.1.276 | ColumneddPort1RxCriticalEventPDURemoteA | read-only | current | EDD Series card Port1 Detailed Link OAM Statistics: Rx Dying Gasp |
| 1.3.6.1.4.1.4756.20.441.20.1.277 | ColumneddPort1TxOAMInfoPDURemoteA | read-only | current | EDD Series card Port1 Detailed Link OAM Statistics: Tx OAM Information PDU's |
| 1.3.6.1.4.1.4756.20.441.20.1.278 | ColumneddPort1TxUniqueErrorEventRemoteA | read-only | current | EDD Series card Port1 Detailed Link OAM Statistics: Tx Unique Error Event Notificatio |
| 1.3.6.1.4.1.4756.20.441.20.1.279 | ColumneddPort1TxDuplicateErrorEventRemoteA | read-only | current | EDD Series card Port1 Detailed Link OAM Statistics: Tx Duplicate Error Event Notification |
| 1.3.6.1.4.1.4756.20.441.20.1.280 | ColumneddPort1TxLoopBackControlRemoteA | read-only | current | EDD Series card Port1 Detailed Link OAM Statistics: Tx Loopback Control |
| 1.3.6.1.4.1.4756.20.441.20.1.281 | ColumneddPort1TxVariableRequestRemoteA | read-only | current | EDD Series card Port1 Detailed Link OAM Statistics: Tx Variable Request |
| 1.3.6.1.4.1.4756.20.441.20.1.282 | ColumneddPort1TxVariableResponseRemoteA | read-only | current | EDD Series card Port1 Detailed Link OAM Statistics: Tx Variable Response |
| 1.3.6.1.4.1.4756.20.441.20.1.283 | ColumneddPort1TxOrgSpecificPDURemoteA | read-only | current | EDD Series card Port1 Detailed Link OAM Statistics: Tx Org Specific PDU's |
| 1.3.6.1.4.1.4756.20.441.20.1.284 | ColumneddPort1TxUnsupportedCodesRemoteA | read-only | current | EDD Series card Port1 Detailed Link OAM Statistics: Tx Unsupported Codes |
| 1.3.6.1.4.1.4756.20.441.20.1.285 | ColumneddPort1TxLinkFaultPDURemoteA | read-only | current | EDD Series card Port1 Detailed Link OAM Statistics: Tx Link Fault PDU's |
| 1.3.6.1.4.1.4756.20.441.20.1.286 | ColumneddPort1TxDyingGaspRemoteA | read-only | current | EDD Series card Port1 Detailed Link OAM Statistics: Tx Dying Gasp |
| 1.3.6.1.4.1.4756.20.441.20.1.287 | ColumneddPort1TxCriticalEventPDURemoteA | read-only | current | EDD Series card Port1 Detailed Link OAM Statistics: Tx Dying Gasp |
| 1.3.6.1.4.1.4756.20.441.20.1.288 | ColumneddPort2RxOAMInfoPDURemoteA | read-only | current | EDD Series card Port2 Detailed Link OAM Statistics: Rx OAM Information PDU's |
| 1.3.6.1.4.1.4756.20.441.20.1.289 | ColumneddPort2RxUniqueErrorEventRemoteA | read-only | current | EDD Series card Port2 Detailed Link OAM Statistics: Rx Unique Error Event Notificatio |
| 1.3.6.1.4.1.4756.20.441.20.1.290 | ColumneddPort2RxDuplicateErrorEventRemoteA | read-only | current | EDD Series card Port2 Detailed Link OAM Statistics: Rx Duplicate Error Event Notification |
| 1.3.6.1.4.1.4756.20.441.20.1.291 | ColumneddPort2RxLoopBackControlRemoteA | read-only | current | EDD Series card Port2 Detailed Link OAM Statistics: Rx Loopback Control |
| 1.3.6.1.4.1.4756.20.441.20.1.292 | ColumneddPort2RxVariableRequestRemoteA | read-only | current | EDD Series card Port2 Detailed Link OAM Statistics: Rx Variable Request |
| 1.3.6.1.4.1.4756.20.441.20.1.293 | ColumneddPort2RxVariableResponseRemoteA | read-only | current | EDD Series card Port2 Detailed Link OAM Statistics: Rx Variable Response |
| 1.3.6.1.4.1.4756.20.441.20.1.294 | ColumneddPort2RxOrgSpecificPDURemoteA | read-only | current | EDD Series card Port2 Detailed Link OAM Statistics: Rx Org Specific PDU's |
| 1.3.6.1.4.1.4756.20.441.20.1.295 | ColumneddPort2RxUnsupportedCodesRemoteA | read-only | current | EDD Series card Port2 Detailed Link OAM Statistics: Rx Unsupported Codes |
| 1.3.6.1.4.1.4756.20.441.20.1.296 | ColumneddPort2RxLinkFaultPDURemoteA | read-only | current | EDD Series card Port2 Detailed Link OAM Statistics: Rx Link Fault PDU's |
| 1.3.6.1.4.1.4756.20.441.20.1.297 | ColumneddPort2RxDyingGaspRemoteA | read-only | current | EDD Series card Port2 Detailed Link OAM Statistics: Rx Dying Gasp |
| 1.3.6.1.4.1.4756.20.441.20.1.298 | ColumneddPort2RxCriticalEventPDURemoteA | read-only | current | EDD Series card Port2 Detailed Link OAM Statistics: Rx Dying Gasp |
| 1.3.6.1.4.1.4756.20.441.20.1.299 | ColumneddPort2TxOAMInfoPDURemoteA | read-only | current | EDD Series card Port2 Detailed Link OAM Statistics: Tx OAM Information PDU's |
| 1.3.6.1.4.1.4756.20.441.20.1.300 | ColumneddPort2TxUniqueErrorEventRemoteA | read-only | current | EDD Series card Port2 Detailed Link OAM Statistics: Tx Unique Error Event Notificatio |
| 1.3.6.1.4.1.4756.20.441.20.1.301 | ColumneddPort2TxDuplicateErrorEventRemoteA | read-only | current | EDD Series card Port2 Detailed Link OAM Statistics: Tx Duplicate Error Event Notification |
| 1.3.6.1.4.1.4756.20.441.20.1.302 | ColumneddPort2TxLoopBackControlRemoteA | read-only | current | EDD Series card Port2 Detailed Link OAM Statistics: Tx Loopback Control |
| 1.3.6.1.4.1.4756.20.441.20.1.303 | ColumneddPort2TxVariableRequestRemoteA | read-only | current | EDD Series card Port2 Detailed Link OAM Statistics: Tx Variable Request |
| 1.3.6.1.4.1.4756.20.441.20.1.304 | ColumneddPort2TxVariableResponseRemoteA | read-only | current | EDD Series card Port2 Detailed Link OAM Statistics: Tx Variable Response |
| 1.3.6.1.4.1.4756.20.441.20.1.305 | ColumneddPort2TxOrgSpecificPDURemoteA | read-only | current | EDD Series card Port2 Detailed Link OAM Statistics: Tx Org Specific PDU's |
| 1.3.6.1.4.1.4756.20.441.20.1.306 | ColumneddPort2TxUnsupportedCodesRemoteA | read-only | current | EDD Series card Port2 Detailed Link OAM Statistics: Tx Unsupported Codes |
| 1.3.6.1.4.1.4756.20.441.20.1.307 | ColumneddPort2TxLinkFaultPDURemoteA | read-only | current | EDD Series card Port2 Detailed Link OAM Statistics: Tx Link Fault PDU's |
| 1.3.6.1.4.1.4756.20.441.20.1.308 | ColumneddPort2TxDyingGaspRemoteA | read-only | current | EDD Series card Port2 Detailed Link OAM Statistics: Tx Dying Gasp |
| 1.3.6.1.4.1.4756.20.441.20.1.309 | ColumneddPort2TxCriticalEventPDURemoteA | read-only | current | EDD Series card Port2 Detailed Link OAM Statistics: Tx Dying Gasp |
| 1.3.6.1.4.1.4756.20.441.20.1.310 | ColumneddPort3RxOAMInfoPDURemoteA | read-only | current | EDD Series card Port3 Detailed Link OAM Statistics: Rx OAM Information PDU's |
| 1.3.6.1.4.1.4756.20.441.20.1.311 | ColumneddPort3RxUniqueErrorEventRemoteA | read-only | current | EDD Series card Port3 Detailed Link OAM Statistics: Rx Unique Error Event Notificatio |
| 1.3.6.1.4.1.4756.20.441.20.1.312 | ColumneddPort3RxDuplicateErrorEventRemoteA | read-only | current | EDD Series card Port3 Detailed Link OAM Statistics: Rx Duplicate Error Event Notification |
| 1.3.6.1.4.1.4756.20.441.20.1.313 | ColumneddPort3RxLoopBackControlRemoteA | read-only | current | EDD Series card Port3 Detailed Link OAM Statistics: Rx Loopback Control |
| 1.3.6.1.4.1.4756.20.441.20.1.314 | ColumneddPort3RxVariableRequestRemoteA | read-only | current | EDD Series card Port3 Detailed Link OAM Statistics: Rx Variable Request |
| 1.3.6.1.4.1.4756.20.441.20.1.315 | ColumneddPort3RxVariableResponseRemoteA | read-only | current | EDD Series card Port3 Detailed Link OAM Statistics: Rx Variable Response |
| 1.3.6.1.4.1.4756.20.441.20.1.316 | ColumneddPort3RxOrgSpecificPDURemoteA | read-only | current | EDD Series card Port3 Detailed Link OAM Statistics: Rx Org Specific PDU's |
| 1.3.6.1.4.1.4756.20.441.20.1.317 | ColumneddPort3RxUnsupportedCodesRemoteA | read-only | current | EDD Series card Port3 Detailed Link OAM Statistics: Rx Unsupported Codes |
| 1.3.6.1.4.1.4756.20.441.20.1.318 | ColumneddPort3RxLinkFaultPDURemoteA | read-only | current | EDD Series card Port3 Detailed Link OAM Statistics: Rx Link Fault PDU's |
| 1.3.6.1.4.1.4756.20.441.20.1.319 | ColumneddPort3RxDyingGaspRemoteA | read-only | current | EDD Series card Port3 Detailed Link OAM Statistics: Rx Dying Gasp |
| 1.3.6.1.4.1.4756.20.441.20.1.320 | ColumneddPort3RxCriticalEventPDURemoteA | read-only | current | EDD Series card Port3 Detailed Link OAM Statistics: Rx Dying Gasp |
| 1.3.6.1.4.1.4756.20.441.20.1.321 | ColumneddPort3TxOAMInfoPDURemoteA | read-only | current | EDD Series card Port3 Detailed Link OAM Statistics: Tx OAM Information PDU's |
| 1.3.6.1.4.1.4756.20.441.20.1.322 | ColumneddPort3TxUniqueErrorEventRemoteA | read-only | current | EDD Series card Port3 Detailed Link OAM Statistics: Tx Unique Error Event Notificatio |
| 1.3.6.1.4.1.4756.20.441.20.1.323 | ColumneddPort3TxDuplicateErrorEventRemoteA | read-only | current | EDD Series card Port3 Detailed Link OAM Statistics: Tx Duplicate Error Event Notification |
| 1.3.6.1.4.1.4756.20.441.20.1.324 | ColumneddPort3TxLoopBackControlRemoteA | read-only | current | EDD Series card Port3 Detailed Link OAM Statistics: Tx Loopback Control |
| 1.3.6.1.4.1.4756.20.441.20.1.325 | ColumneddPort3TxVariableRequestRemoteA | read-only | current | EDD Series card Port3 Detailed Link OAM Statistics: Tx Variable Request |
| 1.3.6.1.4.1.4756.20.441.20.1.326 | ColumneddPort3TxVariableResponseRemoteA | read-only | current | EDD Series card Port3 Detailed Link OAM Statistics: Tx Variable Response |
| 1.3.6.1.4.1.4756.20.441.20.1.327 | ColumneddPort3TxOrgSpecificPDURemoteA | read-only | current | EDD Series card Port3 Detailed Link OAM Statistics: Tx Org Specific PDU's |
| 1.3.6.1.4.1.4756.20.441.20.1.328 | ColumneddPort3TxUnsupportedCodesRemoteA | read-only | current | EDD Series card Port3 Detailed Link OAM Statistics: Tx Unsupported Codes |
| 1.3.6.1.4.1.4756.20.441.20.1.329 | ColumneddPort3TxLinkFaultPDURemoteA | read-only | current | EDD Series card Port3 Detailed Link OAM Statistics: Tx Link Fault PDU's |
| 1.3.6.1.4.1.4756.20.441.20.1.330 | ColumneddPort3TxDyingGaspRemoteA | read-only | current | EDD Series card Port3 Detailed Link OAM Statistics: Tx Dying Gasp |
| 1.3.6.1.4.1.4756.20.441.20.1.331 | ColumneddPort3TxCriticalEventPDURemoteA | read-only | current | EDD Series card Port3 Detailed Link OAM Statistics: Tx Dying Gasp |
| 1.3.6.1.4.1.4756.20.441.20.1.332 | ColumneddPort4RxOAMInfoPDURemoteA | read-only | current | EDD Series card Port4 Detailed Link OAM Statistics: Rx OAM Information PDU's |
| 1.3.6.1.4.1.4756.20.441.20.1.333 | ColumneddPort4RxUniqueErrorEventRemoteA | read-only | current | EDD Series card Port4 Detailed Link OAM Statistics: Rx Unique Error Event Notificatio |
| 1.3.6.1.4.1.4756.20.441.20.1.334 | ColumneddPort4RxDuplicateErrorEventRemoteA | read-only | current | EDD Series card Port4 Detailed Link OAM Statistics: Rx Duplicate Error Event Notification |
| 1.3.6.1.4.1.4756.20.441.20.1.335 | ColumneddPort4RxLoopBackControlRemoteA | read-only | current | EDD Series card Port4 Detailed Link OAM Statistics: Rx Loopback Control |
| 1.3.6.1.4.1.4756.20.441.20.1.336 | ColumneddPort4RxVariableRequestRemoteA | read-only | current | EDD Series card Port4 Detailed Link OAM Statistics: Rx Variable Request |
| 1.3.6.1.4.1.4756.20.441.20.1.337 | ColumneddPort4RxVariableResponseRemoteA | read-only | current | EDD Series card Port4 Detailed Link OAM Statistics: Rx Variable Response |
| 1.3.6.1.4.1.4756.20.441.20.1.338 | ColumneddPort4RxOrgSpecificPDURemoteA | read-only | current | EDD Series card Port4 Detailed Link OAM Statistics: Rx Org Specific PDU's |
| 1.3.6.1.4.1.4756.20.441.20.1.339 | ColumneddPort4RxUnsupportedCodesRemoteA | read-only | current | EDD Series card Port4 Detailed Link OAM Statistics: Rx Unsupported Codes |
| 1.3.6.1.4.1.4756.20.441.20.1.340 | ColumneddPort4RxLinkFaultPDURemoteA | read-only | current | EDD Series card Port4 Detailed Link OAM Statistics: Rx Link Fault PDU's |
| 1.3.6.1.4.1.4756.20.441.20.1.341 | ColumneddPort4RxDyingGaspRemoteA | read-only | current | EDD Series card Port4 Detailed Link OAM Statistics: Rx Dying Gasp |
| 1.3.6.1.4.1.4756.20.441.20.1.342 | ColumneddPort4RxCriticalEventPDURemoteA | read-only | current | EDD Series card Port4 Detailed Link OAM Statistics: Rx Dying Gasp |
| 1.3.6.1.4.1.4756.20.441.20.1.343 | ColumneddPort4TxOAMInfoPDURemoteA | read-only | current | EDD Series card Port4 Detailed Link OAM Statistics: Tx OAM Information PDU's |
| 1.3.6.1.4.1.4756.20.441.20.1.344 | ColumneddPort4TxUniqueErrorEventRemoteA | read-only | current | EDD Series card Port4 Detailed Link OAM Statistics: Tx Unique Error Event Notificatio |
| 1.3.6.1.4.1.4756.20.441.20.1.345 | ColumneddPort4TxDuplicateErrorEventRemoteA | read-only | current | EDD Series card Port4 Detailed Link OAM Statistics: Tx Duplicate Error Event Notification |
| 1.3.6.1.4.1.4756.20.441.20.1.346 | ColumneddPort4TxLoopBackControlRemoteA | read-only | current | EDD Series card Port4 Detailed Link OAM Statistics: Tx Loopback Control |
| 1.3.6.1.4.1.4756.20.441.20.1.347 | ColumneddPort4TxVariableRequestRemoteA | read-only | current | EDD Series card Port4 Detailed Link OAM Statistics: Tx Variable Request |
| 1.3.6.1.4.1.4756.20.441.20.1.348 | ColumneddPort4TxVariableResponseRemoteA | read-only | current | EDD Series card Port4 Detailed Link OAM Statistics: Tx Variable Response |
| 1.3.6.1.4.1.4756.20.441.20.1.349 | ColumneddPort4TxOrgSpecificPDURemoteA | read-only | current | EDD Series card Port4 Detailed Link OAM Statistics: Tx Org Specific PDU's |
| 1.3.6.1.4.1.4756.20.441.20.1.350 | ColumneddPort4TxUnsupportedCodesRemoteA | read-only | current | EDD Series card Port4 Detailed Link OAM Statistics: Tx Unsupported Codes |
| 1.3.6.1.4.1.4756.20.441.20.1.351 | ColumneddPort4TxLinkFaultPDURemoteA | read-only | current | EDD Series card Port4 Detailed Link OAM Statistics: Tx Link Fault PDU's |
| 1.3.6.1.4.1.4756.20.441.20.1.352 | ColumneddPort4TxDyingGaspRemoteA | read-only | current | EDD Series card Port4 Detailed Link OAM Statistics: Tx Dying Gasp |
| 1.3.6.1.4.1.4756.20.441.20.1.353 | ColumneddPort4TxCriticalEventPDURemoteA | read-only | current | EDD Series card Port4 Detailed Link OAM Statistics: Tx Dying Gasp |
| 1.3.6.1.4.1.4756.20.441.20.1.354 | ColumneddPort1PDUPermisionRemoteA | read-only | current | EDD Series card Detailed Link OAM Status for Port 1: PDU Permission |
| 1.3.6.1.4.1.4756.20.441.20.1.355 | ColumneddPort1DiscoveryStateRemoteA | read-only | current | EDD Series card Detailed Link OAM Status for Port 1: Discovery State |
| 1.3.6.1.4.1.4756.20.441.20.1.356 | ColumneddPort1PeerMACAddrRemoteA | read-only | current | EDD Series card Detailed Link OAM Status for Port 1: Discovery State |
| 1.3.6.1.4.1.4756.20.441.20.1.357 | ColumneddPort1LocalModeRemoteA | read-only | current | EDD Series card Detailed Link OAM Status for Port 1: Local: Mode |
| 1.3.6.1.4.1.4756.20.441.20.1.358 | ColumneddPort1LocalUnOperationRemoteA | read-only | current | EDD Series card Detailed Link OAM Status for Port 1: Local: Unidirectional Operation Support |
| 1.3.6.1.4.1.4756.20.441.20.1.359 | ColumneddPort1LocalRemoteLbRemoteA | read-only | current | EDD Series card Detailed Link OAM Status for Port 1: Local: Remote Loopback Support |
| 1.3.6.1.4.1.4756.20.441.20.1.360 | ColumneddPort1LocalLMRemoteA | read-only | current | EDD Series card Detailed Link OAM Status for Port 1: RemoteA: Link Monitoring Support |
| 1.3.6.1.4.1.4756.20.441.20.1.361 | ColumneddPort1LocalMIBRetrievalRemoteA | read-only | current | EDD Series card Detailed Link OAM Status for Port 1: Local: MIB Retrieval Support |
| 1.3.6.1.4.1.4756.20.441.20.1.362 | ColumneddPort1LocalMTUSizeRemoteA | read-only | current | EDD Series card Detailed Link OAM Status for Port 1: Local: MTU Size |
| 1.3.6.1.4.1.4756.20.441.20.1.363 | ColumneddPort1LocalMultiStateRemoteA | read-only | current | EDD Series card Detailed Link OAM Status for Port 1: Local: Multiplexer State |
| 1.3.6.1.4.1.4756.20.441.20.1.364 | ColumneddPort1LocalParserStateRemoteA | read-only | current | EDD Series card Detailed Link OAM Status for Port 1: Local: Multiplexer State |
| 1.3.6.1.4.1.4756.20.441.20.1.365 | ColumneddPort1LocalOUIRemoteA | read-only | current | EDD Series card Detailed Link OAM Status for Port 1: Local: Organizational Unique Identification |
| 1.3.6.1.4.1.4756.20.441.20.1.366 | ColumneddPort1LocalPDURevRemoteA | read-only | current | EDD Series card Detailed Link OAM Status for Port 1: Local: PDU Revision |
| 1.3.6.1.4.1.4756.20.441.20.1.367 | ColumneddPort1PeerModeRemoteA | read-only | current | EDD Series card Detailed Link OAM Status for Port 1: Peer: Mode |
| 1.3.6.1.4.1.4756.20.441.20.1.368 | ColumneddPort1PeerUnOperationRemoteA | read-only | current | EDD Series card Detailed Link OAM Status for Port 1: Peer: Unidirectional Operation Support |
| 1.3.6.1.4.1.4756.20.441.20.1.369 | ColumneddPort1PeerRemoteLbRemoteA | read-only | current | EDD Series card Detailed Link OAM Status for Port 1: Peer: Remote Loopback Support |
| 1.3.6.1.4.1.4756.20.441.20.1.370 | ColumneddPort1PeerLMRemoteA | read-only | current | EDD Series card Detailed Link OAM Status for Port 1: Peer: Link Monitoring Support |
| 1.3.6.1.4.1.4756.20.441.20.1.371 | ColumneddPort1PeerMIBRetrievalRemoteA | read-only | current | EDD Series card Detailed Link OAM Status for Port 1: Peer: MIB Retrieval Support |
| 1.3.6.1.4.1.4756.20.441.20.1.372 | ColumneddPort1PeerMTUSizeRemoteA | read-only | current | EDD Series card Detailed Link OAM Status for Port 1: Peer: MTU Size |
| 1.3.6.1.4.1.4756.20.441.20.1.373 | ColumneddPort1PeerMultiStateRemoteA | read-only | current | EDD Series card Detailed Link OAM Status for Port 1: Peer: Multiplexer State |
| 1.3.6.1.4.1.4756.20.441.20.1.374 | ColumneddPort1PeerParserStateRemoteA | read-only | current | EDD Series card Detailed Link OAM Status for Port 1: Peer: Multiplexer State |
| 1.3.6.1.4.1.4756.20.441.20.1.375 | ColumneddPort1PeerOUIRemoteA | read-only | current | EDD Series card Detailed Link OAM Status for Port 1: Peer: Organizational Unique Identification |
| 1.3.6.1.4.1.4756.20.441.20.1.376 | ColumneddPort1PeerPDURevRemoteA | read-only | current | EDD Series card Detailed Link OAM Status for Port 1: Peer: PDU Revision |
| 1.3.6.1.4.1.4756.20.441.20.1.377 | ColumneddPort2PDUPermisionRemoteA | read-only | current | EDD Series card Detailed Link OAM Status for Port 2: PDU Permission |
| 1.3.6.1.4.1.4756.20.441.20.1.378 | ColumneddPort2DiscoveryStateRemoteA | read-only | current | EDD Series card Detailed Link OAM Status for Port 2: Discovery State |
| 1.3.6.1.4.1.4756.20.441.20.1.379 | ColumneddPort2PeerMACAddrRemoteA | read-only | current | EDD Series card Detailed Link OAM Status for Port 2: Discovery State |
| 1.3.6.1.4.1.4756.20.441.20.1.380 | ColumneddPort2LocalModeRemoteA | read-only | current | EDD Series card Detailed Link OAM Status for Port 2: Local: Mode |
| 1.3.6.1.4.1.4756.20.441.20.1.381 | ColumneddPort2LocalUnOperationRemoteA | read-only | current | EDD Series card Detailed Link OAM Status for Port 2: Local: Unidirectional Operation Support |
| 1.3.6.1.4.1.4756.20.441.20.1.382 | ColumneddPort2LocalRemoteLbRemoteA | read-only | current | EDD Series card Detailed Link OAM Status for Port 2: Local: Remote Loopback Support |
| 1.3.6.1.4.1.4756.20.441.20.1.383 | ColumneddPort2LocalLMRemoteA | read-only | current | EDD Series card Detailed Link OAM Status for Port 2: Local: Link Monitoring Support |
| 1.3.6.1.4.1.4756.20.441.20.1.384 | ColumneddPort2LocalMIBRetrievalRemoteA | read-only | current | EDD Series card Detailed Link OAM Status for Port 2: Local: MIB Retrieval Support |
| 1.3.6.1.4.1.4756.20.441.20.1.385 | ColumneddPort2LocalMTUSizeRemoteA | read-only | current | EDD Series card Detailed Link OAM Status for Port 2: Local: MTU Size |
| 1.3.6.1.4.1.4756.20.441.20.1.386 | ColumneddPort2LocalMultiStateRemoteA | read-only | current | EDD Series card Detailed Link OAM Status for Port 2: Local: Multiplexer State |
| 1.3.6.1.4.1.4756.20.441.20.1.387 | ColumneddPort2LocalParserStateRemoteA | read-only | current | EDD Series card Detailed Link OAM Status for Port 2: Local: Multiplexer State |
| 1.3.6.1.4.1.4756.20.441.20.1.388 | ColumneddPort2LocalOUIRemoteA | read-only | current | EDD Series card Detailed Link OAM Status for Port 2: Local: Organizational Unique Identification |
| 1.3.6.1.4.1.4756.20.441.20.1.389 | ColumneddPort2LocalPDURevRemoteA | read-only | current | EDD Series card Detailed Link OAM Status for Port 2: Local: PDU Revision |
| 1.3.6.1.4.1.4756.20.441.20.1.390 | ColumneddPort2PeerModeRemoteA | read-only | current | EDD Series card Detailed Link OAM Status for Port 2: Peer: Mode |
| 1.3.6.1.4.1.4756.20.441.20.1.391 | ColumneddPort2PeerUnOperationRemoteA | read-only | current | EDD Series card Detailed Link OAM Status for Port 2: Peer: Unidirectional Operation Support |
| 1.3.6.1.4.1.4756.20.441.20.1.392 | ColumneddPort2PeerRemoteLbRemoteA | read-only | current | EDD Series card Detailed Link OAM Status for Port 2: Peer: Remote Loopback Support |
| 1.3.6.1.4.1.4756.20.441.20.1.393 | ColumneddPort2PeerLMRemoteA | read-only | current | EDD Series card Detailed Link OAM Status for Port 2: Peer: Link Monitoring Support |
| 1.3.6.1.4.1.4756.20.441.20.1.394 | ColumneddPort2PeerMIBRetrievalRemoteA | read-only | current | EDD Series card Detailed Link OAM Status for Port 2: Peer: MIB Retrieval Support |
| 1.3.6.1.4.1.4756.20.441.20.1.395 | ColumneddPort2PeerMTUSizeRemoteA | read-only | current | EDD Series card Detailed Link OAM Status for Port 2: Peer: MTU Size |
| 1.3.6.1.4.1.4756.20.441.20.1.396 | ColumneddPort2PeerMultiStateRemoteA | read-only | current | EDD Series card Detailed Link OAM Status for Port 2: Peer: Multiplexer State |
| 1.3.6.1.4.1.4756.20.441.20.1.397 | ColumneddPort2PeerParserStateRemoteA | read-only | current | EDD Series card Detailed Link OAM Status for Port 2: Peer: Multiplexer State |
| 1.3.6.1.4.1.4756.20.441.20.1.398 | ColumneddPort2PeerOUIRemoteA | read-only | current | EDD Series card Detailed Link OAM Status for Port 2: Peer: Organizational Unique Identification |
| 1.3.6.1.4.1.4756.20.441.20.1.399 | ColumneddPort2PeerPDURevRemoteA | read-only | current | EDD Series card Detailed Link OAM Status for Port 2: Peer: PDU Revision |
| 1.3.6.1.4.1.4756.20.441.20.1.400 | ColumneddPort3PDUPermisionRemoteA | read-only | current | EDD Series card Detailed Link OAM Status for Port 3: PDU Permission |
| 1.3.6.1.4.1.4756.20.441.20.1.401 | ColumneddPort3DiscoveryStateRemoteA | read-only | current | EDD Series card Detailed Link OAM Status for Port 3: Discovery State |
| 1.3.6.1.4.1.4756.20.441.20.1.402 | ColumneddPort3PeerMACAddrRemoteA | read-only | current | EDD Series card Detailed Link OAM Status for Port 3: Discovery State |
| 1.3.6.1.4.1.4756.20.441.20.1.403 | ColumneddPort3LocalModeRemoteA | read-only | current | EDD Series card Detailed Link OAM Status for Port 3: Local: Mode |
| 1.3.6.1.4.1.4756.20.441.20.1.404 | ColumneddPort3LocalUnOperationRemoteA | read-only | current | EDD Series card Detailed Link OAM Status for Port 3: Local: Unidirectional Operation Support |
| 1.3.6.1.4.1.4756.20.441.20.1.405 | ColumneddPort3LocalRemoteLbRemoteA | read-only | current | EDD Series card Detailed Link OAM Status for Port 3: Local: Remote Loopback Support |
| 1.3.6.1.4.1.4756.20.441.20.1.406 | ColumneddPort3LocalLMRemoteA | read-only | current | EDD Series card Detailed Link OAM Status for Port 3: Local: Link Monitoring Support |
| 1.3.6.1.4.1.4756.20.441.20.1.407 | ColumneddPort3LocalMIBRetrievalRemoteA | read-only | current | EDD Series card Detailed Link OAM Status for Port 3: Local: MIB Retrieval Support |
| 1.3.6.1.4.1.4756.20.441.20.1.408 | ColumneddPort3LocalMTUSizeRemoteA | read-only | current | EDD Series card Detailed Link OAM Status for Port 3: Local: MTU Size |
| 1.3.6.1.4.1.4756.20.441.20.1.409 | ColumneddPort3LocalMultiStateRemoteA | read-only | current | EDD Series card Detailed Link OAM Status for Port 3: Local: Multiplexer State |
| 1.3.6.1.4.1.4756.20.441.20.1.410 | ColumneddPort3LocalParserStateRemoteA | read-only | current | EDD Series card Detailed Link OAM Status for Port 3: Local: Multiplexer State |
| 1.3.6.1.4.1.4756.20.441.20.1.411 | ColumneddPort3LocalOUIRemoteA | read-only | current | EDD Series card Detailed Link OAM Status for Port 3: Local: Organizational Unique Identification |
| 1.3.6.1.4.1.4756.20.441.20.1.412 | ColumneddPort3LocalPDURevRemoteA | read-only | current | EDD Series card Detailed Link OAM Status for Port 3: Local: PDU Revision |
| 1.3.6.1.4.1.4756.20.441.20.1.413 | ColumneddPort3PeerModeRemoteA | read-only | current | EDD Series card Detailed Link OAM Status for Port 3: Peer: Mode |
| 1.3.6.1.4.1.4756.20.441.20.1.414 | ColumneddPort3PeerUnOperationRemoteA | read-only | current | EDD Series card Detailed Link OAM Status for Port 3: Peer: Unidirectional Operation Support |
| 1.3.6.1.4.1.4756.20.441.20.1.415 | ColumneddPort3PeerRemoteLbRemoteA | read-only | current | EDD Series card Detailed Link OAM Status for Port 3: Peer: Remote Loopback Support |
| 1.3.6.1.4.1.4756.20.441.20.1.416 | ColumneddPort3PeerLMRemoteA | read-only | current | EDD Series card Detailed Link OAM Status for Port 3: Peer: Link Monitoring Support |
| 1.3.6.1.4.1.4756.20.441.20.1.417 | ColumneddPort3PeerMIBRetrievalRemoteA | read-only | current | EDD Series card Detailed Link OAM Status for Port 3: Peer: MIB Retrieval Support |
| 1.3.6.1.4.1.4756.20.441.20.1.418 | ColumneddPort3PeerMTUSizeRemoteA | read-only | current | EDD Series card Detailed Link OAM Status for Port 3: Peer: MTU Size |
| 1.3.6.1.4.1.4756.20.441.20.1.419 | ColumneddPort3PeerMultiStateRemoteA | read-only | current | EDD Series card Detailed Link OAM Status for Port 3: Peer: Multiplexer State |
| 1.3.6.1.4.1.4756.20.441.20.1.420 | ColumneddPort3PeerParserStateRemoteA | read-only | current | EDD Series card Detailed Link OAM Status for Port 3: Peer: Multiplexer State |
| 1.3.6.1.4.1.4756.20.441.20.1.421 | ColumneddPort3PeerOUIRemoteA | read-only | current | EDD Series card Detailed Link OAM Status for Port 3: Peer: Organizational Unique Identification |
| 1.3.6.1.4.1.4756.20.441.20.1.422 | ColumneddPort3PeerPDURevRemoteA | read-only | current | EDD Series card Detailed Link OAM Status for Port 3: Peer: PDU Revision |
| 1.3.6.1.4.1.4756.20.441.20.1.423 | ColumneddPort4PDUPermisionRemoteA | read-only | current | EDD Series card Detailed Link OAM Status for Port 4: PDU Permission |
| 1.3.6.1.4.1.4756.20.441.20.1.424 | ColumneddPort4DiscoveryStateRemoteA | read-only | current | EDD Series card Detailed Link OAM Status for Port 4: Discovery State |
| 1.3.6.1.4.1.4756.20.441.20.1.425 | ColumneddPort4PeerMACAddrRemoteA | read-only | current | EDD Series card Detailed Link OAM Status for Port 4: Discovery State |
| 1.3.6.1.4.1.4756.20.441.20.1.426 | ColumneddPort4LocalModeRemoteA | read-only | current | EDD Series card Detailed Link OAM Status for Port 4: Local: Mode |
| 1.3.6.1.4.1.4756.20.441.20.1.427 | ColumneddPort4LocalUnOperationRemoteA | read-only | current | EDD Series card Detailed Link OAM Status for Port 4: Local: Unidirectional Operation Support |
| 1.3.6.1.4.1.4756.20.441.20.1.428 | ColumneddPort4LocalRemoteLbRemoteA | read-only | current | EDD Series card Detailed Link OAM Status for Port 4: Local: Remote Loopback Support |
| 1.3.6.1.4.1.4756.20.441.20.1.429 | ColumneddPort4LocalLMRemoteA | read-only | current | EDD Series card Detailed Link OAM Status for Port 4: Local: Link Monitoring Support |
| 1.3.6.1.4.1.4756.20.441.20.1.430 | ColumneddPort4LocalMIBRetrievalRemoteA | read-only | current | EDD Series card Detailed Link OAM Status for Port 4: Local: MIB Retrieval Support |
| 1.3.6.1.4.1.4756.20.441.20.1.431 | ColumneddPort4LocalMTUSizeRemoteA | read-only | current | EDD Series card Detailed Link OAM Status for Port 4: Local: MTU Size |
| 1.3.6.1.4.1.4756.20.441.20.1.432 | ColumneddPort4LocalMultiStateRemoteA | read-only | current | EDD Series card Detailed Link OAM Status for Port 4: Local: Multiplexer State |
| 1.3.6.1.4.1.4756.20.441.20.1.433 | ColumneddPort4LocalParserStateRemoteA | read-only | current | EDD Series card Detailed Link OAM Status for Port 4: Local: Multiplexer State |
| 1.3.6.1.4.1.4756.20.441.20.1.434 | ColumneddPort4LocalOUIRemoteA | read-only | current | EDD Series card Detailed Link OAM Status for Port 4: Local: Organizational Unique Identification |
| 1.3.6.1.4.1.4756.20.441.20.1.435 | ColumneddPort4LocalPDURevRemoteA | read-only | current | EDD Series card Detailed Link OAM Status for Port 4: Local: PDU Revision |
| 1.3.6.1.4.1.4756.20.441.20.1.436 | ColumneddPort4PeerModeRemoteA | read-only | current | EDD Series card Detailed Link OAM Status for Port 4: Peer: Mode |
| 1.3.6.1.4.1.4756.20.441.20.1.437 | ColumneddPort4PeerUnOperationRemoteA | read-only | current | EDD Series card Detailed Link OAM Status for Port 4: Peer: Unidirectional Operation Support |
| 1.3.6.1.4.1.4756.20.441.20.1.438 | ColumneddPort4PeerRemoteLbRemoteA | read-only | current | EDD Series card Detailed Link OAM Status for Port 4: Peer: Remote Loopback Support |
| 1.3.6.1.4.1.4756.20.441.20.1.439 | ColumneddPort4PeerLMRemoteA | read-only | current | EDD Series card Detailed Link OAM Status for Port 4: Peer: Link Monitoring Support |
| 1.3.6.1.4.1.4756.20.441.20.1.440 | ColumneddPort4PeerMIBRetrievalRemoteA | read-only | current | EDD Series card Detailed Link OAM Status for Port 4: Peer: MIB Retrieval Support |
| 1.3.6.1.4.1.4756.20.441.20.1.441 | ColumneddPort4PeerMTUSizeRemoteA | read-only | current | EDD Series card Detailed Link OAM Status for Port 4: Peer: MTU Size |
| 1.3.6.1.4.1.4756.20.441.20.1.442 | ColumneddPort4PeerMultiStateRemoteA | read-only | current | EDD Series card Detailed Link OAM Status for Port 4: Peer: Multiplexer State |
| 1.3.6.1.4.1.4756.20.441.20.1.443 | ColumneddPort4PeerParserStateRemoteA | read-only | current | EDD Series card Detailed Link OAM Status for Port 4: Peer: Multiplexer State |
| 1.3.6.1.4.1.4756.20.441.20.1.444 | ColumneddPort4PeerOUIRemoteA | read-only | current | EDD Series card Detailed Link OAM Status for Port 4: Peer: Organizational Unique Identification |
| 1.3.6.1.4.1.4756.20.441.20.1.445 | ColumneddPort4PeerPDURevRemoteA | read-only | current | EDD Series card Detailed Link OAM Status for Port 4: Peer: PDU Revision |
| 1.3.6.1.4.1.4756.20.441.20.1.446 | ColumneddCLEAROAMCOUNTERRemoteA | read-write | current | EDD Series card Clear OAM Counter: 0: Off 1: Action |
| 1.3.6.1.4.1.4756.20.441.20.1.447 | ColumneddLoopProtectionEnableRemoteA | read-write | current | EDD Series card Loop Protection Configuration: General Settings - Enable Loop Protection 0: Disable 1: Enable |
| 1.3.6.1.4.1.4756.20.441.20.1.448 | ColumneddLoopProtectionTxTimeRemoteA | read-write | current | EDD Series card Loop Protection Configuration: General Settings - Transmission Time |
| 1.3.6.1.4.1.4756.20.441.20.1.449 | ColumneddLoopProtectionShutdownTimeRemoteA | read-write | current | EDD Series card Loop Protection Configuration: General Settings - Shutdown Time |
| 1.3.6.1.4.1.4756.20.441.20.1.450 | ColumneddLoopProtectionPort1EnabledRemoteA | read-write | current | EDD Series card Loop Protection Configuration for Port 1: Port Configuration - Enable 0: Disable 1: Enable |
| 1.3.6.1.4.1.4756.20.441.20.1.451 | ColumneddLoopProtectionPort1ActionRemoteA | read-write | current | EDD Series card Loop Protection Configuration for Port 1: Port Configuration - Action 0: Shutdown Port 1: Shutdown Port And Log 2: Log Only |
| 1.3.6.1.4.1.4756.20.441.20.1.452 | ColumneddLoopProtectionPort1TxModeRemoteA | read-write | current | EDD Series card Loop Protection Configuration for Port 1: Port Configuration - Tx Mode 0: Disable 1: Enable |
| 1.3.6.1.4.1.4756.20.441.20.1.453 | ColumneddLoopProtectionPort2EnabledRemoteA | read-write | current | EDD Series card Loop Protection Configuration for Port 2: Port Configuration - Enable 0: Disable 1: Enable |
| 1.3.6.1.4.1.4756.20.441.20.1.454 | ColumneddLoopProtectionPort2ActionRemoteA | read-write | current | EDD Series card Loop Protection Configuration for Port 2: Port Configuration - Action 0: Shutdown Port 1: Shutdown Port And Log 2: Log Only |
| 1.3.6.1.4.1.4756.20.441.20.1.455 | ColumneddLoopProtectionPort2TxModeRemoteA | read-write | current | EDD Series card Loop Protection Configuration for Port 2: Port Configuration - Tx Mode 0: Disable 1: Enable |
| 1.3.6.1.4.1.4756.20.441.20.1.456 | ColumneddLoopProtectionPort3EnabledRemoteA | read-write | current | EDD Series card Loop Protection Configuration for Port 3: Port Configuration - Enable 0: Disable 1: Enable |
| 1.3.6.1.4.1.4756.20.441.20.1.457 | ColumneddLoopProtectionPort3ActionRemoteA | read-write | current | EDD Series card Loop Protection Configuration for Port 3: Port Configuration - Action 0: Shutdown Port 1: Shutdown Port And Log 2: Log Only |
| 1.3.6.1.4.1.4756.20.441.20.1.458 | ColumneddLoopProtectionPort3TxModeRemoteA | read-write | current | EDD Series card Loop Protection Configuration for Port 3: Port Configuration - Tx Mode 0: Disable 1: Enable |
| 1.3.6.1.4.1.4756.20.441.20.1.459 | ColumneddLoopProtectionPort4EnabledRemoteA | read-write | current | EDD Series card Loop Protection Configuration for Port 4: Port Configuration - Enable 0: Disable 1: Enable |
| 1.3.6.1.4.1.4756.20.441.20.1.460 | ColumneddLoopProtectionPort4ActionRemoteA | read-write | current | EDD Series card Loop Protection Configuration for Port 4: Port Configuration - Action 0: Shutdown Port 1: Shutdown Port And Log 2: Log Only |
| 1.3.6.1.4.1.4756.20.441.20.1.461 | ColumneddLoopProtectionPort4TxModeRemoteA | read-write | current | EDD Series card Loop Protection Configuration for Port 41: Port Configuration - Tx Mode 0: Disable 1: Enable |
| 1.3.6.1.4.1.4756.20.441.20.1.462 | ColumneddLoopProtectionPort1ActionStsRemoteA | read-only | current | EDD Series card Loop Protection Status for Port 1: Action |
| 1.3.6.1.4.1.4756.20.441.20.1.463 | ColumneddLoopProtectionPort1TransStsRemoteA | read-only | current | EDD Series card Loop Protection Status for Port 1: Transmit |
| 1.3.6.1.4.1.4756.20.441.20.1.464 | ColumneddLoopProtectionPort1LoopsStsRemoteA | read-only | current | EDD Series card Loop Protection Status for Port 1: Loops |
| 1.3.6.1.4.1.4756.20.441.20.1.465 | ColumneddLoopProtectionPort1StatusRemoteA | read-only | current | EDD Series card Loop Protection Status for Port 1: Status |
| 1.3.6.1.4.1.4756.20.441.20.1.466 | ColumneddLoopProtectionPort1LoopStsRemoteA | read-only | current | EDD Series card Loop Protection Status for Port 1: Loop |
| 1.3.6.1.4.1.4756.20.441.20.1.467 | ColumneddLoopProtectionPort1TimeOfLastLoopRemoteA | read-only | current | EDD Series card Loop Protection Status for Port 1: Time of Last Loop |
| 1.3.6.1.4.1.4756.20.441.20.1.468 | ColumneddLoopProtectionPort2ActionStsRemoteA | read-only | current | EDD Series card Loop Protection Status for Port 2: Action |
| 1.3.6.1.4.1.4756.20.441.20.1.469 | ColumneddLoopProtectionPort2TransStsRemoteA | read-only | current | EDD Series card Loop Protection Status for Port 2: Transmit |
| 1.3.6.1.4.1.4756.20.441.20.1.470 | ColumneddLoopProtectionPort2LoopsStsRemoteA | read-only | current | EDD Series card Loop Protection Status for Port 2: Loops |
| 1.3.6.1.4.1.4756.20.441.20.1.471 | ColumneddLoopProtectionPort2StatusRemoteA | read-only | current | EDD Series card Loop Protection Status for Port 2: Status |
| 1.3.6.1.4.1.4756.20.441.20.1.472 | ColumneddLoopProtectionPort2LoopStsRemoteA | read-only | current | EDD Series card Loop Protection Status for Port 2: Loop |
| 1.3.6.1.4.1.4756.20.441.20.1.473 | ColumneddLoopProtectionPort2TimeOfLastLoopRemoteA | read-only | current | EDD Series card Loop Protection Status for Port 2: Time of Last Loop |
| 1.3.6.1.4.1.4756.20.441.20.1.474 | ColumneddLoopProtectionPort3ActionStsRemoteA | read-only | current | EDD Series card Loop Protection Status for Port 3: Action |
| 1.3.6.1.4.1.4756.20.441.20.1.475 | ColumneddLoopProtectionPort3TransStsRemoteA | read-only | current | EDD Series card Loop Protection Status for Port 3: Transmit |
| 1.3.6.1.4.1.4756.20.441.20.1.476 | ColumneddLoopProtectionPort3LoopsStsRemoteA | read-only | current | EDD Series card Loop Protection Status for Port 3: Loops |
| 1.3.6.1.4.1.4756.20.441.20.1.477 | ColumneddLoopProtectionPort3StatusRemoteA | read-only | current | EDD Series card Loop Protection Status for Port 3: Status |
| 1.3.6.1.4.1.4756.20.441.20.1.478 | ColumneddLoopProtectionPort3LoopStsRemoteA | read-only | current | EDD Series card Loop Protection Status for Port 3: Loop |
| 1.3.6.1.4.1.4756.20.441.20.1.479 | ColumneddLoopProtectionPort3TimeOfLastLoopRemoteA | read-only | current | EDD Series card Loop Protection Status for Port 3: Time of Last Loop |
| 1.3.6.1.4.1.4756.20.441.20.1.480 | ColumneddLoopProtectionPort4ActionStsRemoteA | read-only | current | EDD Series card Loop Protection Status for Port 4: Action |
| 1.3.6.1.4.1.4756.20.441.20.1.481 | ColumneddLoopProtectionPort4TransStsRemoteA | read-only | current | EDD Series card Loop Protection Status for Port 4: Transmit |
| 1.3.6.1.4.1.4756.20.441.20.1.482 | ColumneddLoopProtectionPort4LoopsStsRemoteA | read-only | current | EDD Series card Loop Protection Status for Port 4: Loops |
| 1.3.6.1.4.1.4756.20.441.20.1.483 | ColumneddLoopProtectionPort4StatusRemoteA | read-only | current | EDD Series card Loop Protection Status for Port 4: Status |
| 1.3.6.1.4.1.4756.20.441.20.1.484 | ColumneddLoopProtectionPort4LoopStsRemoteA | read-only | current | EDD Series card Loop Protection Status for Port 4: Loop |
| 1.3.6.1.4.1.4756.20.441.20.1.485 | ColumneddLoopProtectionPort4TimeOfLastLoopRemoteA | read-only | current | EDD Series card Loop Protection Status for Port 4: Time of Last Loop |
| 1.3.6.1.4.1.4756.20.441.20.1.486 | ColumneddSTPProtocolVersionRemoteA | read-write | current | EDD Series card STP Bridge Configuration: Basic Settings - Protocol Version 0: STP 1: RSTP 2: MSTP |
| 1.3.6.1.4.1.4756.20.441.20.1.487 | ColumneddSTPBridgePriorityRemoteA | read-write | current | EDD Series card STP Bridge Configuration: Basic Settings - Bridge Priority 0: 0 1: 4096 2: 8192 3: 12288 4: 16384 5: 20480 6: 24576 7: 28672 8: 32768 9: 36864 … |
| 1.3.6.1.4.1.4756.20.441.20.1.488 | ColumneddSTPForwardDelayRemoteA | read-write | current | EDD Series card STP Bridge Configuration: Basic Settings - Forward Delay |
| 1.3.6.1.4.1.4756.20.441.20.1.489 | ColumneddSTPMaxAgeRemoteA | read-write | current | EDD Series card STP Bridge Configuration: Basic Settings - Max Age |
| 1.3.6.1.4.1.4756.20.441.20.1.490 | ColumneddSTPMaximumHopCountRemoteA | read-write | current | EDD Series card STP Bridge Configuration: Basic Settings - Maximum Hop Count |
| 1.3.6.1.4.1.4756.20.441.20.1.491 | ColumneddSTPTransmitHoldCountRemoteA | read-write | current | EDD Series card STP Bridge Configuration: Basic Settings - Transmit Hold Count |
| 1.3.6.1.4.1.4756.20.441.20.1.492 | ColumneddSTPEdgePortBPDUFilteringRemoteA | read-write | current | EDD Series card STP Bridge Configuration: Advanced Settings - Edge Port BPDU Filtering 0: Off 1: On |
| 1.3.6.1.4.1.4756.20.441.20.1.493 | ColumneddSTPEdgePortBPDUGuardRemoteA | read-write | current | EDD Series card STP Bridge Configuration: Advanced Settings - Edge Port BPDU Guard 0: Off 1: On |
| 1.3.6.1.4.1.4756.20.441.20.1.494 | ColumneddSTPPortErrorRecoveryTimeoutRemoteA | read-write | current | EDD Series card STP Bridge Configuration: Advanced Settings - Port Error Recovery Timeout 0: Off 1: On |
| 1.3.6.1.4.1.4756.20.441.20.1.495 | ColumneddMSTIConfigurationNameRemoteA | read-write | current | EDD Series card MSTI Configuration: Configuration Identification - Configuration Name |
| 1.3.6.1.4.1.4756.20.441.20.1.496 | ColumneddMSTIConfigurationRevisionRemoteA | read-write | current | EDD Series card MSTI Configuration: Configuration Identification - Configuration Revision |
| 1.3.6.1.4.1.4756.20.441.20.1.497 | ColumneddMSTI1VLANsMappingRemoteA | read-write | current | EDD Series card MSTI Configuration: MSTI Mapping - MSTI 1 |
| 1.3.6.1.4.1.4756.20.441.20.1.498 | ColumneddMSTI2VLANsMappingRemoteA | read-write | current | EDD Series card MSTI Configuration: MSTI Mapping - MSTI 2 |
| 1.3.6.1.4.1.4756.20.441.20.1.499 | ColumneddMSTI3VLANsMappingRemoteA | read-write | current | EDD Series card MSTI Configuration: MSTI Mapping - MSTI 3 |
| 1.3.6.1.4.1.4756.20.441.20.1.500 | ColumneddMSTI4VLANsMappingRemoteA | read-write | current | EDD Series card MSTI Configuration: MSTI Mapping - MSTI 4 |
| 1.3.6.1.4.1.4756.20.441.20.1.501 | ColumneddMSTI5VLANsMappingRemoteA | read-write | current | EDD Series card MSTI Configuration: MSTI Mapping - MSTI 5 |
| 1.3.6.1.4.1.4756.20.441.20.1.502 | ColumneddMSTI6VLANsMappingRemoteA | read-write | current | EDD Series card MSTI Configuration: MSTI Mapping - MSTI 6 |
| 1.3.6.1.4.1.4756.20.441.20.1.503 | ColumneddMSTI7VLANsMappingRemoteA | read-write | current | EDD Series card MSTI Configuration: MSTI Mapping - MSTI 7 |
| 1.3.6.1.4.1.4756.20.441.20.1.504 | ColumneddCISTAggregatedSTPEnabledRemoteA | read-write | current | EDD Series card STP CIST Port Configuration: CIST Aggregated Port Configuration - STP Enabled |
| 1.3.6.1.4.1.4756.20.441.20.1.505 | ColumneddCISTAggregatedPathCostRemoteA | read-write | current | EDD Series card STP CIST Port Configuration: CIST Aggregated Port Configuration - Path Cost Valid values are in the range 0 to 200000000. Setting 0 means Auto … |
| 1.3.6.1.4.1.4756.20.441.20.1.506 | ColumneddCISTAggregatedPriorityRemoteA | read-write | current | EDD Series card STP CIST Port Configuration: CIST Aggregated Port Configuration - Priority |
| 1.3.6.1.4.1.4756.20.441.20.1.507 | ColumneddCISTAggregatedAdminEdgeRemoteA | read-write | current | EDD Series card STP CIST Port Configuration: CIST Aggregated Port Configuration - STP Enabled 0: Non-edge 1: Edge |
| 1.3.6.1.4.1.4756.20.441.20.1.508 | ColumneddCISTAggregatedAutoEdgeRemoteA | read-write | current | EDD Series card STP CIST Port Configuration: CIST Aggregated Port Configuration - Auto Edge 0: Non-edge 1: Edge |
| 1.3.6.1.4.1.4756.20.441.20.1.509 | ColumneddCISTAggregatedRestrictedRoleRemoteA | read-write | current | EDD Series card STP CIST Port Configuration: CIST Aggregated Port Configuration - Restricted Role 0: Non-edge 1: Edge |
| 1.3.6.1.4.1.4756.20.441.20.1.510 | ColumneddCISTAggregatedRestrictedTCNRemoteA | read-write | current | EDD Series card STP CIST Port Configuration: CIST Aggregated Port Configuration - Restricted TCN 0: Non-edge 1: Edge |
| 1.3.6.1.4.1.4756.20.441.20.1.511 | ColumneddCISTAggregatedBPDUGuardRemoteA | read-write | current | EDD Series card STP CIST Port Configuration: CIST Aggregated Port Configuration - BPDU Guard 0: Non-edge 1: Edge |
| 1.3.6.1.4.1.4756.20.441.20.1.512 | ColumneddCISTAggregatedPointToPointRemoteA | read-write | current | EDD Series card STP CIST Port Configuration: CIST Aggregated Port Configuration - Point-to-point 0: Forced True 1: Forced False 2: Auto |
| 1.3.6.1.4.1.4756.20.441.20.1.513 | ColumneddCISTPort1STPEnabledRemoteA | read-write | current | EDD Series card STP CIST Port Configuration: CIST Normal Port1 Configuration - STP Enabled |
| 1.3.6.1.4.1.4756.20.441.20.1.514 | ColumneddCISTPort1PathCostRemoteA | read-write | current | EDD Series card STP CIST Port Configuration: CIST Normal Port1 Configuration - Path Cost Valid values are in the range 0 to 200000000. Setting 0 means Auto pat… |
| 1.3.6.1.4.1.4756.20.441.20.1.515 | ColumneddCISTPort1PriorityRemoteA | read-write | current | EDD Series card STP CIST Port Configuration: CIST Normal Port1 Configuration - Priority |
| 1.3.6.1.4.1.4756.20.441.20.1.516 | ColumneddCISTPort1AdminEdgeRemoteA | read-write | current | EDD Series card STP CIST Port Configuration: CIST Normal Port1 Configuration - STP Enabled 0: Non-edge 1: Edge |
| 1.3.6.1.4.1.4756.20.441.20.1.517 | ColumneddCISTPort1AutoEdgeRemoteA | read-write | current | EDD Series card STP CIST Port Configuration: CIST Normal Port1 Configuration - Auto Edge 0: Non-edge 1: Edge |
| 1.3.6.1.4.1.4756.20.441.20.1.518 | ColumneddCISTPort1RestrictedRoleRemoteA | read-write | current | EDD Series card STP CIST Port Configuration: CIST Normal Port1 Configuration - Restricted Role 0: Non-edge 1: Edge |
| 1.3.6.1.4.1.4756.20.441.20.1.519 | ColumneddCISTPort1RestrictedTCNRemoteA | read-write | current | EDD Series card STP CIST Port Configuration: CIST Normal Port1 Configuration - Restricted TCN 0: Non-edge 1: Edge |
| 1.3.6.1.4.1.4756.20.441.20.1.520 | ColumneddCISTPort1BPDUGuardRemoteA | read-write | current | EDD Series card STP CIST Port Configuration: CIST Normal Port1 Configuration - BPDU Guard 0: Non-edge 1: Edge |
| 1.3.6.1.4.1.4756.20.441.20.1.521 | ColumneddCISTPort1PointToPointRemoteA | read-write | current | EDD Series card STP CIST Port Configuration: CIST Normal Port1 Configuration - Point-to-point 0: Forced True 1: Forced False 2: Auto |
| 1.3.6.1.4.1.4756.20.441.20.1.522 | ColumneddCISTPort2STPEnabledRemoteA | read-write | current | EDD Series card STP CIST Port Configuration: CIST Normal Port2 Configuration - STP Enabled |
| 1.3.6.1.4.1.4756.20.441.20.1.523 | ColumneddCISTPort2PathCostRemoteA | read-write | current | EDD Series card STP CIST Port Configuration: CIST Normal Port2 Configuration - Path Cost Valid values are in the range 0 to 200000000. Setting 0 means Auto pat… |
| 1.3.6.1.4.1.4756.20.441.20.1.524 | ColumneddCISTPort2PriorityRemoteA | read-write | current | EDD Series card STP CIST Port Configuration: CIST Normal Port2 Configuration - Priority |
| 1.3.6.1.4.1.4756.20.441.20.1.525 | ColumneddCISTPort2AdminEdgeRemoteA | read-write | current | EDD Series card STP CIST Port Configuration: CIST Normal Port2 Configuration - STP Enabled 0: Non-edge 1: Edge |
| 1.3.6.1.4.1.4756.20.441.20.1.526 | ColumneddCISTPort2AutoEdgeRemoteA | read-write | current | EDD Series card STP CIST Port Configuration: CIST Normal Port2 Configuration - Auto Edge 0: Non-edge 1: Edge |
| 1.3.6.1.4.1.4756.20.441.20.1.527 | ColumneddCISTPort2RestrictedRoleRemoteA | read-write | current | EDD Series card STP CIST Port Configuration: CIST Normal Port2 Configuration - Restricted Role 0: Non-edge 1: Edge |
| 1.3.6.1.4.1.4756.20.441.20.1.528 | ColumneddCISTPort2RestrictedTCNRemoteA | read-write | current | EDD Series card STP CIST Port Configuration: CIST Normal Port2 Configuration - Restricted TCN 0: Non-edge 1: Edge |
| 1.3.6.1.4.1.4756.20.441.20.1.529 | ColumneddCISTPort2BPDUGuardRemoteA | read-write | current | EDD Series card STP CIST Port Configuration: CIST Normal Port2 Configuration - BPDU Guard 0: Non-edge 1: Edge |
| 1.3.6.1.4.1.4756.20.441.20.1.530 | ColumneddCISTPort2PointToPointRemoteA | read-write | current | EDD Series card STP CIST Port Configuration: CIST Normal Port2 Configuration - Point-to-point 0: Forced True 1: Forced False 2: Auto |
| 1.3.6.1.4.1.4756.20.441.20.1.531 | ColumneddCISTPort3STPEnabledRemoteA | read-write | current | EDD Series card STP CIST Port Configuration: CIST Normal Port3 Configuration - STP Enabled |
| 1.3.6.1.4.1.4756.20.441.20.1.532 | ColumneddCISTPort3PathCostRemoteA | read-write | current | EDD Series card STP CIST Port Configuration: CIST Normal Port3 Configuration - Path Cost Valid values are in the range 0 to 200000000. Setting 0 means Auto pat… |
| 1.3.6.1.4.1.4756.20.441.20.1.533 | ColumneddCISTPort3PriorityRemoteA | read-write | current | EDD Series card STP CIST Port Configuration: CIST Normal Port3 Configuration - Priority |
| 1.3.6.1.4.1.4756.20.441.20.1.534 | ColumneddCISTPort3AdminEdgeRemoteA | read-write | current | EDD Series card STP CIST Port Configuration: CIST Normal Port3 Configuration - STP Enabled 0: Non-edge 1: Edge |
| 1.3.6.1.4.1.4756.20.441.20.1.535 | ColumneddCISTPort3AutoEdgeRemoteA | read-write | current | EDD Series card STP CIST Port Configuration: CIST Normal Port3 Configuration - Auto Edge 0: Non-edge 1: Edge |
| 1.3.6.1.4.1.4756.20.441.20.1.536 | ColumneddCISTPort3RestrictedRoleRemoteA | read-write | current | EDD Series card STP CIST Port Configuration: CIST Normal Port3 Configuration - Restricted Role 0: Non-edge 1: Edge |
| 1.3.6.1.4.1.4756.20.441.20.1.537 | ColumneddCISTPort3RestrictedTCNRemoteA | read-write | current | EDD Series card STP CIST Port Configuration: CIST Normal Port3 Configuration - Restricted TCN 0: Non-edge 1: Edge |
| 1.3.6.1.4.1.4756.20.441.20.1.538 | ColumneddCISTPort3BPDUGuardRemoteA | read-write | current | EDD Series card STP CIST Port Configuration: CIST Normal Port3 Configuration - BPDU Guard 0: Non-edge 1: Edge |
| 1.3.6.1.4.1.4756.20.441.20.1.539 | ColumneddCISTPort3PointToPointRemoteA | read-write | current | EDD Series card STP CIST Port Configuration: CIST Normal Port3 Configuration - Point-to-point 0: Forced True 1: Forced False 2: Auto |
| 1.3.6.1.4.1.4756.20.441.20.1.540 | ColumneddCISTPort4STPEnabledRemoteA | read-write | current | EDD Series card STP CIST Port Configuration: CIST Normal Port4 Configuration - STP Enabled |
| 1.3.6.1.4.1.4756.20.441.20.1.541 | ColumneddCISTPort4PathCostRemoteA | read-write | current | EDD Series card STP CIST Port Configuration: CIST Normal Port4 Configuration - Path Cost Valid values are in the range 0 to 200000000. Setting 0 means Auto pat… |
| 1.3.6.1.4.1.4756.20.441.20.1.542 | ColumneddCISTPort4PriorityRemoteA | read-write | current | EDD Series card STP CIST Port Configuration: CIST Normal Port4 Configuration - Priority |
| 1.3.6.1.4.1.4756.20.441.20.1.543 | ColumneddCISTPort4AdminEdgeRemoteA | read-write | current | EDD Series card STP CIST Port Configuration: CIST Normal Port4 Configuration - STP Enabled 0: Non-edge 1: Edge |
| 1.3.6.1.4.1.4756.20.441.20.1.544 | ColumneddCISTPort4AutoEdgeRemoteA | read-write | current | EDD Series card STP CIST Port Configuration: CIST Normal Port4 Configuration - Auto Edge 0: Non-edge 1: Edge |
| 1.3.6.1.4.1.4756.20.441.20.1.545 | ColumneddCISTPort4RestrictedRoleRemoteA | read-write | current | EDD Series card STP CIST Port Configuration: CIST Normal Port4 Configuration - Restricted Role 0: Non-edge 1: Edge |
| 1.3.6.1.4.1.4756.20.441.20.1.546 | ColumneddCISTPort4RestrictedTCNRemoteA | read-write | current | EDD Series card STP CIST Port Configuration: CIST Normal Port4 Configuration - Restricted TCN 0: Non-edge 1: Edge |
| 1.3.6.1.4.1.4756.20.441.20.1.547 | ColumneddCISTPort4BPDUGuardRemoteA | read-write | current | EDD Series card STP CIST Port Configuration: CIST Normal Port4 Configuration - BPDU Guard 0: Non-edge 1: Edge |
| 1.3.6.1.4.1.4756.20.441.20.1.548 | ColumneddCISTPort4PointToPointRemoteA | read-write | current | EDD Series card STP CIST Port Configuration: CIST Normal Port4 Configuration - Point-to-point 0: Forced True 1: Forced False 2: Auto |
| 1.3.6.1.4.1.4756.20.441.20.1.549 | ColumneddMSTI1AggregatedPathCostRemoteA | read-write | current | EDD Series card MSTI Port Configuration: MSTI1 Aggregated Ports Configuration - Path Cost Valid values are in the range 0 to 200000000. Setting 0 means Auto pa… |
| 1.3.6.1.4.1.4756.20.441.20.1.550 | ColumneddMSTI1AggregatedPriorityRemoteA | read-write | current | EDD Series card MSTI Port Configuration: MSTI1 Aggregated Ports Configuration - Priority |
| 1.3.6.1.4.1.4756.20.441.20.1.551 | ColumneddMSTI1Port1PathCostRemoteA | read-write | current | EDD Series card MSTI Port Configuration: MSTI1 Normal Port1 Configuration - Path Cost Valid values are in the range 0 to 200000000. Setting 0 means Auto path c… |
| 1.3.6.1.4.1.4756.20.441.20.1.552 | ColumneddMSTI1Port1PriorityRemoteA | read-write | current | EDD Series card MSTI Port Configuration: MSTI1 Normal Port1 Configuration - Priority |
| 1.3.6.1.4.1.4756.20.441.20.1.553 | ColumneddMSTI1Port2PathCostRemoteA | read-write | current | EDD Series card MSTI Port Configuration: MSTI1 Normal Port2 Configuration - Path Cost Valid values are in the range 0 to 200000000. Setting 0 means Auto path c… |
| 1.3.6.1.4.1.4756.20.441.20.1.554 | ColumneddMSTI1Port2PriorityRemoteA | read-write | current | EDD Series card MSTI Port Configuration: MSTI1 Normal Port2 Configuration - Priority |
| 1.3.6.1.4.1.4756.20.441.20.1.555 | ColumneddMSTI1Port3PathCostRemoteA | read-write | current | EDD Series card MSTI Port Configuration: MSTI1 Normal Port3 Configuration - Path Cost Valid values are in the range 0 to 200000000. Setting 0 means Auto path c… |
| 1.3.6.1.4.1.4756.20.441.20.1.556 | ColumneddMSTI1Port3PriorityRemoteA | read-write | current | EDD Series card MSTI Port Configuration: MSTI1 Normal Port3 Configuration - Priority |
| 1.3.6.1.4.1.4756.20.441.20.1.557 | ColumneddMSTI1Port4PathCostRemoteA | read-write | current | EDD Series card MSTI Port Configuration: MSTI1 Normal Port4 Configuration - Path Cost Valid values are in the range 0 to 200000000. Setting 0 means Auto path c… |
| 1.3.6.1.4.1.4756.20.441.20.1.558 | ColumneddMSTI1Port4PriorityRemoteA | read-write | current | EDD Series card MSTI Port Configuration: MSTI1 Normal Port4 Configuration - Priority |
| 1.3.6.1.4.1.4756.20.441.20.1.559 | ColumneddMSTI2AggregatedPathCostRemoteA | read-write | current | EDD Series card MSTI Port Configuration: MSTI2 Aggregated Ports Configuration - Path Cost Valid values are in the range 0 to 200000000. Setting 0 means Auto pa… |
| 1.3.6.1.4.1.4756.20.441.20.1.560 | ColumneddMSTI2AggregatedPriorityRemoteA | read-write | current | EDD Series card MSTI Port Configuration: MSTI2 Aggregated Ports Configuration - Priority |
| 1.3.6.1.4.1.4756.20.441.20.1.561 | ColumneddMSTI2Port1PathCostRemoteA | read-write | current | EDD Series card MSTI Port Configuration: MSTI2 Normal Port1 Configuration - Path Cost Valid values are in the range 0 to 200000000. Setting 0 means Auto path c… |
| 1.3.6.1.4.1.4756.20.441.20.1.562 | ColumneddMSTI2Port1PriorityRemoteA | read-write | current | EDD Series card MSTI Port Configuration: MSTI2 Normal Port1 Configuration - Priority |
| 1.3.6.1.4.1.4756.20.441.20.1.563 | ColumneddMSTI2Port2PathCostRemoteA | read-write | current | EDD Series card MSTI Port Configuration: MSTI2 Normal Port2 Configuration - Path Cost Valid values are in the range 0 to 200000000. Setting 0 means Auto path c… |
| 1.3.6.1.4.1.4756.20.441.20.1.564 | ColumneddMSTI2Port2PriorityRemoteA | read-write | current | EDD Series card MSTI Port Configuration: MSTI2 Normal Port2 Configuration - Priority |
| 1.3.6.1.4.1.4756.20.441.20.1.565 | ColumneddMSTI2Port3PathCostRemoteA | read-write | current | EDD Series card MSTI Port Configuration: MSTI2 Normal Port3 Configuration - Path Cost Valid values are in the range 0 to 200000000. Setting 0 means Auto path c… |
| 1.3.6.1.4.1.4756.20.441.20.1.566 | ColumneddMSTI2Port3PriorityRemoteA | read-write | current | EDD Series card MSTI Port Configuration: MSTI2 Normal Port3 Configuration - Priority |
| 1.3.6.1.4.1.4756.20.441.20.1.567 | ColumneddMSTI2Port4PathCostRemoteA | read-write | current | EDD Series card MSTI Port Configuration: MSTI2 Normal Port4 Configuration - Path Cost Valid values are in the range 0 to 200000000. Setting 0 means Auto path c… |
| 1.3.6.1.4.1.4756.20.441.20.1.568 | ColumneddMSTI2Port4PriorityRemoteA | read-write | current | EDD Series card MSTI Port Configuration: MSTI2 Normal Port4 Configuration - Priority |
| 1.3.6.1.4.1.4756.20.441.20.1.569 | ColumneddMSTI3AggregatedPathCostRemoteA | read-write | current | EDD Series card MSTI Port Configuration: MSTI3 Aggregated Ports Configuration - Path Cost Valid values are in the range 0 to 200000000. Setting 0 means Auto pa… |
| 1.3.6.1.4.1.4756.20.441.20.1.570 | ColumneddMSTI3AggregatedPriorityRemoteA | read-write | current | EDD Series card MSTI Port Configuration: MSTI3 Aggregated Ports Configuration - Priority |
| 1.3.6.1.4.1.4756.20.441.20.1.571 | ColumneddMSTI3Port1PathCostRemoteA | read-write | current | EDD Series card MSTI Port Configuration: MSTI3 Normal Port1 Configuration - Path Cost Valid values are in the range 0 to 200000000. Setting 0 means Auto path c… |
| 1.3.6.1.4.1.4756.20.441.20.1.572 | ColumneddMSTI3Port1PriorityRemoteA | read-write | current | EDD Series card MSTI Port Configuration: MSTI3 Normal Port1 Configuration - Priority |
| 1.3.6.1.4.1.4756.20.441.20.1.573 | ColumneddMSTI3Port2PathCostRemoteA | read-write | current | EDD Series card MSTI Port Configuration: MSTI3 Normal Port2 Configuration - Path Cost Valid values are in the range 0 to 200000000. Setting 0 means Auto path c… |
| 1.3.6.1.4.1.4756.20.441.20.1.574 | ColumneddMSTI3Port2PriorityRemoteA | read-write | current | EDD Series card MSTI Port Configuration: MSTI3 Normal Port2 Configuration - Priority |
| 1.3.6.1.4.1.4756.20.441.20.1.575 | ColumneddMSTI3Port3PathCostRemoteA | read-write | current | EDD Series card MSTI Port Configuration: MSTI1 Normal Port3 Configuration - Path Cost Valid values are in the range 0 to 200000000. Setting 0 means Auto path c… |
| 1.3.6.1.4.1.4756.20.441.20.1.576 | ColumneddMSTI3Port3PriorityRemoteA | read-write | current | EDD Series card MSTI Port Configuration: MSTI3 Normal Port3 Configuration - Priority |
| 1.3.6.1.4.1.4756.20.441.20.1.577 | ColumneddMSTI3Port4PathCostRemoteA | read-write | current | EDD Series card MSTI Port Configuration: MSTI3 Normal Port4 Configuration - Path Cost Valid values are in the range 0 to 200000000. Setting 0 means Auto path c… |
| 1.3.6.1.4.1.4756.20.441.20.1.578 | ColumneddMSTI3Port4PriorityRemoteA | read-write | current | EDD Series card MSTI Port Configuration: MSTI3 Normal Port4 Configuration - Priority |
| 1.3.6.1.4.1.4756.20.441.20.1.579 | ColumneddMSTI4AggregatedPathCostRemoteA | read-write | current | EDD Series card MSTI Port Configuration: MSTI4 Aggregated Ports Configuration - Path Cost Valid values are in the range 0 to 200000000. Setting 0 means Auto pa… |
| 1.3.6.1.4.1.4756.20.441.20.1.580 | ColumneddMSTI4AggregatedPriorityRemoteA | read-write | current | EDD Series card MSTI Port Configuration: MSTI4 Aggregated Ports Configuration - Priority |
| 1.3.6.1.4.1.4756.20.441.20.1.581 | ColumneddMSTI4Port1PathCostRemoteA | read-write | current | EDD Series card MSTI Port Configuration: MSTI4 Normal Port1 Configuration - Path Cost Valid values are in the range 0 to 200000000. Setting 0 means Auto path c… |
| 1.3.6.1.4.1.4756.20.441.20.1.582 | ColumneddMSTI4Port1PriorityRemoteA | read-write | current | EDD Series card MSTI Port Configuration: MSTI4 Normal Port1 Configuration - Priority |
| 1.3.6.1.4.1.4756.20.441.20.1.583 | ColumneddMSTI4Port2PathCostRemoteA | read-write | current | EDD Series card MSTI Port Configuration: MSTI4 Normal Port2 Configuration - Path Cost Valid values are in the range 0 to 200000000. Setting 0 means Auto path c… |
| 1.3.6.1.4.1.4756.20.441.20.1.584 | ColumneddMSTI4Port2PriorityRemoteA | read-write | current | EDD Series card MSTI Port Configuration: MSTI4 Normal Port2 Configuration - Priority |
| 1.3.6.1.4.1.4756.20.441.20.1.585 | ColumneddMSTI4Port3PathCostRemoteA | read-write | current | EDD Series card MSTI Port Configuration: MSTI1 Normal Port3 Configuration - Path Cost Valid values are in the range 0 to 200000000. Setting 0 means Auto path c… |
| 1.3.6.1.4.1.4756.20.441.20.1.586 | ColumneddMSTI4Port3PriorityRemoteA | read-write | current | EDD Series card MSTI Port Configuration: MSTI4 Normal Port3 Configuration - Priority |
| 1.3.6.1.4.1.4756.20.441.20.1.587 | ColumneddMSTI4Port4PathCostRemoteA | read-write | current | EDD Series card MSTI Port Configuration: MSTI4 Normal Port4 Configuration - Path Cost Valid values are in the range 0 to 200000000. Setting 0 means Auto path c… |
| 1.3.6.1.4.1.4756.20.441.20.1.588 | ColumneddMSTI4Port4PriorityRemoteA | read-write | current | EDD Series card MSTI Port Configuration: MSTI4 Normal Port4 Configuration - Priority |
| 1.3.6.1.4.1.4756.20.441.20.1.589 | ColumneddMSTI5AggregatedPathCostRemoteA | read-write | current | EDD Series card MSTI Port Configuration: MSTI5 Aggregated Ports Configuration - Path Cost Valid values are in the range 0 to 200000000. Setting 0 means Auto pa… |
| 1.3.6.1.4.1.4756.20.441.20.1.590 | ColumneddMSTI5AggregatedPriorityRemoteA | read-write | current | EDD Series card MSTI Port Configuration: MSTI5 Aggregated Ports Configuration - Priority |
| 1.3.6.1.4.1.4756.20.441.20.1.591 | ColumneddMSTI5Port1PathCostRemoteA | read-write | current | EDD Series card MSTI Port Configuration: MSTI5 Normal Port1 Configuration - Path Cost Valid values are in the range 0 to 200000000. Setting 0 means Auto path c… |
| 1.3.6.1.4.1.4756.20.441.20.1.592 | ColumneddMSTI5Port1PriorityRemoteA | read-write | current | EDD Series card MSTI Port Configuration: MSTI5 Normal Port1 Configuration - Priority |
| 1.3.6.1.4.1.4756.20.441.20.1.593 | ColumneddMSTI5Port2PathCostRemoteA | read-write | current | EDD Series card MSTI Port Configuration: MSTI5 Normal Port2 Configuration - Path Cost Valid values are in the range 0 to 200000000. Setting 0 means Auto path c… |
| 1.3.6.1.4.1.4756.20.441.20.1.594 | ColumneddMSTI5Port2PriorityRemoteA | read-write | current | EDD Series card MSTI Port Configuration: MSTI5 Normal Port2 Configuration - Priority |
| 1.3.6.1.4.1.4756.20.441.20.1.595 | ColumneddMSTI5Port3PathCostRemoteA | read-write | current | EDD Series card MSTI Port Configuration: MSTI5 Normal Port3 Configuration - Path Cost Valid values are in the range 0 to 200000000. Setting 0 means Auto path c… |
| 1.3.6.1.4.1.4756.20.441.20.1.596 | ColumneddMSTI5Port3PriorityRemoteA | read-write | current | EDD Series card MSTI Port Configuration: MSTI5 Normal Port3 Configuration - Priority |
| 1.3.6.1.4.1.4756.20.441.20.1.597 | ColumneddMSTI5Port4PathCostRemoteA | read-write | current | EDD Series card MSTI Port Configuration: MSTI5 Normal Port4 Configuration - Path Cost Valid values are in the range 0 to 200000000. Setting 0 means Auto path c… |
| 1.3.6.1.4.1.4756.20.441.20.1.598 | ColumneddMSTI5Port4PriorityRemoteA | read-write | current | EDD Series card MSTI Port Configuration: MSTI5 Normal Port4 Configuration - Priority |
| 1.3.6.1.4.1.4756.20.441.20.1.599 | ColumneddMSTI6AggregatedPathCostRemoteA | read-write | current | EDD Series card MSTI Port Configuration: MSTI6 Aggregated Ports Configuration - Path Cost Valid values are in the range 0 to 200000000. Setting 0 means Auto pa… |
| 1.3.6.1.4.1.4756.20.441.20.1.600 | ColumneddMSTI6AggregatedPriorityRemoteA | read-write | current | EDD Series card MSTI Port Configuration: MSTI6 Aggregated Ports Configuration - Priority |
| 1.3.6.1.4.1.4756.20.441.20.1.601 | ColumneddMSTI6Port1PathCostRemoteA | read-write | current | EDD Series card MSTI Port Configuration: MSTI6 Normal Port1 Configuration - Path Cost Valid values are in the range 0 to 200000000. Setting 0 means Auto path c… |
| 1.3.6.1.4.1.4756.20.441.20.1.602 | ColumneddMSTI6Port1PriorityRemoteA | read-write | current | EDD Series card MSTI Port Configuration: MSTI6 Normal Port1 Configuration - Priority |
| 1.3.6.1.4.1.4756.20.441.20.1.603 | ColumneddMSTI6Port2PathCostRemoteA | read-write | current | EDD Series card MSTI Port Configuration: MSTI6 Normal Port2 Configuration - Path Cost Valid values are in the range 0 to 200000000. Setting 0 means Auto path c… |
| 1.3.6.1.4.1.4756.20.441.20.1.604 | ColumneddMSTI6Port2PriorityRemoteA | read-write | current | EDD Series card MSTI Port Configuration: MSTI6 Normal Port2 Configuration - Priority |
| 1.3.6.1.4.1.4756.20.441.20.1.605 | ColumneddMSTI6Port3PathCostRemoteA | read-write | current | EDD Series card MSTI Port Configuration: MSTI6 Normal Port3 Configuration - Path Cost Valid values are in the range 0 to 200000000. Setting 0 means Auto path c… |
| 1.3.6.1.4.1.4756.20.441.20.1.606 | ColumneddMSTI6Port3PriorityRemoteA | read-write | current | EDD Series card MSTI Port Configuration: MSTI6 Normal Port3 Configuration - Priority |
| 1.3.6.1.4.1.4756.20.441.20.1.607 | ColumneddMSTI6Port4PathCostRemoteA | read-write | current | EDD Series card MSTI Port Configuration: MSTI6 Normal Port4 Configuration - Path Cost Valid values are in the range 0 to 200000000. Setting 0 means Auto path c… |
| 1.3.6.1.4.1.4756.20.441.20.1.608 | ColumneddMSTI6Port4PriorityRemoteA | read-write | current | EDD Series card MSTI Port Configuration: MSTI6 Normal Port4 Configuration - Priority |
| 1.3.6.1.4.1.4756.20.441.20.1.609 | ColumneddMSTI7AggregatedPathCostRemoteA | read-write | current | EDD Series card MSTI Port Configuration: MSTI7 Aggregated Ports Configuration - Path Cost Valid values are in the range 0 to 200000000. Setting 0 means Auto pa… |
| 1.3.6.1.4.1.4756.20.441.20.1.610 | ColumneddMSTI7AggregatedPriorityRemoteA | read-write | current | EDD Series card MSTI Port Configuration: MSTI7 Aggregated Ports Configuration - Priority |
| 1.3.6.1.4.1.4756.20.441.20.1.611 | ColumneddMSTI7Port1PathCostRemoteA | read-write | current | EDD Series card MSTI Port Configuration: MSTI1 Normal Port1 Configuration - Path Cost Valid values are in the range 0 to 200000000. Setting 0 means Auto path c… |
| 1.3.6.1.4.1.4756.20.441.20.1.612 | ColumneddMSTI7Port1PriorityRemoteA | read-write | current | EDD Series card MSTI Port Configuration: MSTI1 Normal Port7 Configuration - Priority |
| 1.3.6.1.4.1.4756.20.441.20.1.613 | ColumneddMSTI7Port2PathCostRemoteA | read-write | current | EDD Series card MSTI Port Configuration: MSTI7 Normal Port2 Configuration - Path Cost Valid values are in the range 0 to 200000000. Setting 0 means Auto path c… |
| 1.3.6.1.4.1.4756.20.441.20.1.614 | ColumneddMSTI7Port2PriorityRemoteA | read-write | current | EDD Series card MSTI Port Configuration: MSTI7 Normal Port2 Configuration - Priority |
| 1.3.6.1.4.1.4756.20.441.20.1.615 | ColumneddMSTI7Port3PathCostRemoteA | read-write | current | EDD Series card MSTI Port Configuration: MSTI7 Normal Port3 Configuration - Path Cost Valid values are in the range 0 to 200000000. Setting 0 means Auto path c… |
| 1.3.6.1.4.1.4756.20.441.20.1.616 | ColumneddMSTI7Port3PriorityRemoteA | read-write | current | EDD Series card MSTI Port Configuration: MSTI7 Normal Port3 Configuration - Priority |
| 1.3.6.1.4.1.4756.20.441.20.1.617 | ColumneddMSTI7Port4PathCostRemoteA | read-write | current | EDD Series card MSTI Port Configuration: MSTI7 Normal Port4 Configuration - Path Cost Valid values are in the range 0 to 200000000. Setting 0 means Auto path c… |
| 1.3.6.1.4.1.4756.20.441.20.1.618 | ColumneddMSTI7Port4PriorityRemoteA | read-write | current | EDD Series card MSTI Port Configuration: MSTI7 Normal Port4 Configuration - Priority |
| 1.3.6.1.4.1.4756.20.441.20.1.619 | ColumneddCISTBridgeIDRemoteA | read-only | current | EDD Series card STP Bridges status: CIST - Bridge ID |
| 1.3.6.1.4.1.4756.20.441.20.1.620 | ColumneddCISTRootIDRemoteA | read-only | current | EDD Series card STP Bridges status: CIST - Root ID |
| 1.3.6.1.4.1.4756.20.441.20.1.621 | ColumneddCISTRootPortRemoteA | read-only | current | EDD Series card STP Bridges status: CIST - Root Port |
| 1.3.6.1.4.1.4756.20.441.20.1.622 | ColumneddCISTRootCostRemoteA | read-only | current | EDD Series card STP Bridges status: CIST - Root Cost |
| 1.3.6.1.4.1.4756.20.441.20.1.623 | ColumneddCISTTopologyFlagRemoteA | read-only | current | EDD Series card STP Bridges status: CIST - Topology Flag |
| 1.3.6.1.4.1.4756.20.441.20.1.624 | ColumneddCISTTopologyChangeLastRemoteA | read-only | current | EDD Series card STP Bridges status: CIST - Topology Change Last |
| 1.3.6.1.4.1.4756.20.441.20.1.625 | ColumneddMSTI1BridgeIDRemoteA | read-only | current | EDD Series card STP Bridges status: MSTI1 - Bridge ID |
| 1.3.6.1.4.1.4756.20.441.20.1.626 | ColumneddMSTI1RootIDRemoteA | read-only | current | EDD Series card STP Bridges status: MSTI1 - Root ID |
| 1.3.6.1.4.1.4756.20.441.20.1.627 | ColumneddMSTI1RootPortRemoteA | read-only | current | EDD Series card STP Bridges status: MSTI1 - Root ID |
| 1.3.6.1.4.1.4756.20.441.20.1.628 | ColumneddMSTI1RootCostRemoteA | read-only | current | EDD Series card STP Bridges status: MSTI1 - Root Cost |
| 1.3.6.1.4.1.4756.20.441.20.1.629 | ColumneddMSTI1TopologyFlagRemoteA | read-only | current | EDD Series card STP Bridges status: MSTI1 - Topology Flag |
| 1.3.6.1.4.1.4756.20.441.20.1.630 | ColumneddMSTI1TopologyChangeLastRemoteA | read-only | current | EDD Series card STP Bridges status: MSTI1 - Topology Change Last |
| 1.3.6.1.4.1.4756.20.441.20.1.631 | ColumneddMSTI2BridgeIDRemoteA | read-only | current | EDD Series card STP Bridges status: MSTI2 - Bridge ID |
| 1.3.6.1.4.1.4756.20.441.20.1.632 | ColumneddMSTI2RootIDRemoteA | read-only | current | EDD Series card STP Bridges status: MSTI2 - Root ID |
| 1.3.6.1.4.1.4756.20.441.20.1.633 | ColumneddMSTI2RootPortRemoteA | read-only | current | EDD Series card STP Bridges status: MSTI2 - Root ID |
| 1.3.6.1.4.1.4756.20.441.20.1.634 | ColumneddMSTI2RootCostRemoteA | read-only | current | EDD Series card STP Bridges status: MSTI2 - Root Cost |
| 1.3.6.1.4.1.4756.20.441.20.1.635 | ColumneddMSTI2TopologyFlagRemoteA | read-only | current | EDD Series card STP Bridges status: MSTI2 - Topology Flag |
| 1.3.6.1.4.1.4756.20.441.20.1.636 | ColumneddMSTI2TopologyChangeLastRemoteA | read-only | current | EDD Series card STP Bridges status: MSTI2 - Topology Change Last |
| 1.3.6.1.4.1.4756.20.441.20.1.637 | ColumneddMSTI3BridgeIDRemoteA | read-only | current | EDD Series card STP Bridges status: MSTI3 - Bridge ID |
| 1.3.6.1.4.1.4756.20.441.20.1.638 | ColumneddMSTI3RootIDRemoteA | read-only | current | EDD Series card STP Bridges status: MSTI3 - Root ID |
| 1.3.6.1.4.1.4756.20.441.20.1.639 | ColumneddMSTI3RootPortRemoteA | read-only | current | EDD Series card STP Bridges status: MSTI3 - Root ID |
| 1.3.6.1.4.1.4756.20.441.20.1.640 | ColumneddMSTI3RootCostRemoteA | read-only | current | EDD Series card STP Bridges status: MSTI3 - Root Cost |
| 1.3.6.1.4.1.4756.20.441.20.1.641 | ColumneddMSTI3TopologyFlagRemoteA | read-only | current | EDD Series card STP Bridges status: MSTI3 - Topology Flag |
| 1.3.6.1.4.1.4756.20.441.20.1.642 | ColumneddMSTI3TopologyChangeLastRemoteA | read-only | current | EDD Series card STP Bridges status: MSTI3 - Topology Change Last |
| 1.3.6.1.4.1.4756.20.441.20.1.643 | ColumneddMSTI4BridgeIDRemoteA | read-only | current | EDD Series card STP Bridges status: MSTI4 - Bridge ID |
| 1.3.6.1.4.1.4756.20.441.20.1.644 | ColumneddMSTI4RootIDRemoteA | read-only | current | EDD Series card STP Bridges status: MSTI4 - Root ID |
| 1.3.6.1.4.1.4756.20.441.20.1.645 | ColumneddMSTI4RootPortRemoteA | read-only | current | EDD Series card STP Bridges status: MSTI4 - Root ID |
| 1.3.6.1.4.1.4756.20.441.20.1.646 | ColumneddMSTI4RootCostRemoteA | read-only | current | EDD Series card STP Bridges status: MSTI4 - Root Cost |
| 1.3.6.1.4.1.4756.20.441.20.1.647 | ColumneddMSTI4TopologyFlagRemoteA | read-only | current | EDD Series card STP Bridges status: MSTI4 - Topology Flag |
| 1.3.6.1.4.1.4756.20.441.20.1.648 | ColumneddMSTI4TopologyChangeLastRemoteA | read-only | current | EDD Series card STP Bridges status: MSTI4 - Topology Change Last |
| 1.3.6.1.4.1.4756.20.441.20.1.649 | ColumneddMSTI5BridgeIDRemoteA | read-only | current | EDD Series card STP Bridges status: MSTI5 - Bridge ID |
| 1.3.6.1.4.1.4756.20.441.20.1.650 | ColumneddMSTI5RootIDRemoteA | read-only | current | EDD Series card STP Bridges status: MSTI5 - Root ID |
| 1.3.6.1.4.1.4756.20.441.20.1.651 | ColumneddMSTI5RootPortRemoteA | read-only | current | EDD Series card STP Bridges status: MSTI5 - Root ID |
| 1.3.6.1.4.1.4756.20.441.20.1.652 | ColumneddMSTI5RootCostRemoteA | read-only | current | EDD Series card STP Bridges status: MSTI5 - Root Cost |
| 1.3.6.1.4.1.4756.20.441.20.1.653 | ColumneddMSTI5TopologyFlagRemoteA | read-only | current | EDD Series card STP Bridges status: MSTI5 - Topology Flag |
| 1.3.6.1.4.1.4756.20.441.20.1.654 | ColumneddMSTI5TopologyChangeLastRemoteA | read-only | current | EDD Series card STP Bridges status: MSTI5 - Topology Change Last |
| 1.3.6.1.4.1.4756.20.441.20.1.655 | ColumneddMSTI6BridgeIDRemoteA | read-only | current | EDD Series card STP Bridges status: MSTI6 - Bridge ID |
| 1.3.6.1.4.1.4756.20.441.20.1.656 | ColumneddMSTI6RootIDRemoteA | read-only | current | EDD Series card STP Bridges status: MSTI6 - Root ID |
| 1.3.6.1.4.1.4756.20.441.20.1.657 | ColumneddMSTI6RootPortRemoteA | read-only | current | EDD Series card STP Bridges status: MSTI6 - Root ID |
| 1.3.6.1.4.1.4756.20.441.20.1.658 | ColumneddMSTI6RootCostRemoteA | read-only | current | EDD Series card STP Bridges status: MSTI6 - Root Cost |
| 1.3.6.1.4.1.4756.20.441.20.1.659 | ColumneddMSTI6TopologyFlagRemoteA | read-only | current | EDD Series card STP Bridges status: MSTI6 - Topology Flag |
| 1.3.6.1.4.1.4756.20.441.20.1.660 | ColumneddMSTI6TopologyChangeLastRemoteA | read-only | current | EDD Series card STP Bridges status: MSTI6 - Topology Change Last |
| 1.3.6.1.4.1.4756.20.441.20.1.661 | ColumneddMSTI7BridgeIDRemoteA | read-only | current | EDD Series card STP Bridges status: MSTI7 - Bridge ID |
| 1.3.6.1.4.1.4756.20.441.20.1.662 | ColumneddMSTI7RootIDRemoteA | read-only | current | EDD Series card STP Bridges status: MSTI7 - Root ID |
| 1.3.6.1.4.1.4756.20.441.20.1.663 | ColumneddMSTI7RootPortRemoteA | read-only | current | EDD Series card STP Bridges status: MSTI7 - Root ID |
| 1.3.6.1.4.1.4756.20.441.20.1.664 | ColumneddMSTI7RootCostRemoteA | read-only | current | EDD Series card STP Bridges status: MSTI7 - Root Cost |
| 1.3.6.1.4.1.4756.20.441.20.1.665 | ColumneddMSTI7TopologyFlagRemoteA | read-only | current | EDD Series card STP Bridges status: MSTI7 - Topology Flag |
| 1.3.6.1.4.1.4756.20.441.20.1.666 | ColumneddMSTI7TopologyChangeLastRemoteA | read-only | current | EDD Series card STP Bridges status: MSTI7 - Topology Change Last |
| 1.3.6.1.4.1.4756.20.441.20.1.667 | ColumneddSTPPortStatusInst1PortRemoteA | read-only | current | EDD Series card STP Port status: Instance1 - Port |
| 1.3.6.1.4.1.4756.20.441.20.1.668 | ColumneddSTPPortStatusInst1CISTRoleRemoteA | read-only | current | EDD Series card STP Port status: Instance1 - CIST Role |
| 1.3.6.1.4.1.4756.20.441.20.1.669 | ColumneddSTPPortStatusInst1CISTStateRemoteA | read-only | current | EDD Series card STP Port status: Instance1 - CIST State |
| 1.3.6.1.4.1.4756.20.441.20.1.670 | ColumneddSTPPortStatusInst1UptimeRemoteA | read-only | current | EDD Series card STP Port status: Instance1 -Uptime |
| 1.3.6.1.4.1.4756.20.441.20.1.671 | ColumneddSTPPortStatusInst2PortRemoteA | read-only | current | EDD Series card STP Port status: Instance2 - Port |
| 1.3.6.1.4.1.4756.20.441.20.1.672 | ColumneddSTPPortStatusInst2CISTRoleRemoteA | read-only | current | EDD Series card STP Port status: Instance2 - CIST Role |
| 1.3.6.1.4.1.4756.20.441.20.1.673 | ColumneddSTPPortStatusInst2CISTStateRemoteA | read-only | current | EDD Series card STP Port status: Instance2 - CIST State |
| 1.3.6.1.4.1.4756.20.441.20.1.674 | ColumneddSTPPortStatusInst2UptimeRemoteA | read-only | current | EDD Series card STP Port status: Instance2 -Uptime |
| 1.3.6.1.4.1.4756.20.441.20.1.675 | ColumneddSTPPortStatusInst3PortRemoteA | read-only | current | EDD Series card STP Port status: Instance3 - Port |
| 1.3.6.1.4.1.4756.20.441.20.1.676 | ColumneddSTPPortStatusInst3CISTRoleRemoteA | read-only | current | EDD Series card STP Port status: Instance3 - CIST Role |
| 1.3.6.1.4.1.4756.20.441.20.1.677 | ColumneddSTPPortStatusInst3CISTStateRemoteA | read-only | current | EDD Series card STP Port status: Instance3 - CIST State |
| 1.3.6.1.4.1.4756.20.441.20.1.678 | ColumneddSTPPortStatusInst3UptimeRemoteA | read-only | current | EDD Series card STP Port status: Instance3 -Uptime |
| 1.3.6.1.4.1.4756.20.441.20.1.679 | ColumneddSTPPortStatusInst4PortRemoteA | read-only | current | EDD Series card STP Port status: Instance4 - Port |
| 1.3.6.1.4.1.4756.20.441.20.1.680 | ColumneddSTPPortStatusInst4CISTRoleRemoteA | read-only | current | EDD Series card STP Port status: Instance4 - CIST Role |
| 1.3.6.1.4.1.4756.20.441.20.1.681 | ColumneddSTPPortStatusInst4CISTStateRemoteA | read-only | current | EDD Series card STP Port status: Instance4 - CIST State |
| 1.3.6.1.4.1.4756.20.441.20.1.682 | ColumneddSTPPortStatusInst4UptimeRemoteA | read-only | current | EDD Series card STP Port status: Instance4 -Uptime |
| 1.3.6.1.4.1.4756.20.441.20.1.683 | ColumneddSTPStatisticsPort1TxMSTPRemoteA | read-only | current | EDD Series card STP Port Statistics: Port1 -Transmitted MSTP |
| 1.3.6.1.4.1.4756.20.441.20.1.684 | ColumneddSTPStatisticsPort1TxRSTPRemoteA | read-only | current | EDD Series card STP Port Statistics: Port1 -Transmitted RSTP |
| 1.3.6.1.4.1.4756.20.441.20.1.685 | ColumneddSTPStatisticsPort1TxSTPRemoteA | read-only | current | EDD Series card STP Port Statistics: Port1 -Transmitted RSTP |
| 1.3.6.1.4.1.4756.20.441.20.1.686 | ColumneddSTPStatisticsPort1TxTCNRemoteA | read-only | current | EDD Series card STP Port Statistics: Port1 -Transmitted RSTP |
| 1.3.6.1.4.1.4756.20.441.20.1.687 | ColumneddSTPStatisticsPort1RxMSTPRemoteA | read-only | current | EDD Series card STP Port Statistics: Port1 -Received MSTP |
| 1.3.6.1.4.1.4756.20.441.20.1.688 | ColumneddSTPStatisticsPort1RxRSTPRemoteA | read-only | current | EDD Series card STP Port Statistics: Port1 -Received RSTP |
| 1.3.6.1.4.1.4756.20.441.20.1.689 | ColumneddSTPStatisticsPort1RxSTPRemoteA | read-only | current | EDD Series card STP Port Statistics: Port1 -Received RSTP |
| 1.3.6.1.4.1.4756.20.441.20.1.690 | ColumneddSTPStatisticsPort1RxTCNRemoteA | read-only | current | EDD Series card STP Port Statistics: Port1 -Received RSTP |
| 1.3.6.1.4.1.4756.20.441.20.1.691 | ColumneddSTPStatisticsPort1DiscardUnknowRemoteA | read-only | current | EDD Series card STP Port Statistics: Port1 -Discarded Unknown |
| 1.3.6.1.4.1.4756.20.441.20.1.692 | ColumneddSTPStatisticsPort1DiscardIllegalRemoteA | read-only | current | EDD Series card STP Port Statistics: Port1 -Discarded Illegal |
| 1.3.6.1.4.1.4756.20.441.20.1.693 | ColumneddSTPStatisticsPort2TxMSTPRemoteA | read-only | current | EDD Series card STP Port Statistics: Port2 -Transmitted MSTP |
| 1.3.6.1.4.1.4756.20.441.20.1.694 | ColumneddSTPStatisticsPort2TxRSTPRemoteA | read-only | current | EDD Series card STP Port Statistics: Port2 -Transmitted RSTP |
| 1.3.6.1.4.1.4756.20.441.20.1.695 | ColumneddSTPStatisticsPort2TxSTPRemoteA | read-only | current | EDD Series card STP Port Statistics: Port2 -Transmitted RSTP |
| 1.3.6.1.4.1.4756.20.441.20.1.696 | ColumneddSTPStatisticsPort2TxTCNRemoteA | read-only | current | EDD Series card STP Port Statistics: Port2 -Transmitted RSTP |
| 1.3.6.1.4.1.4756.20.441.20.1.697 | ColumneddSTPStatisticsPort2RxMSTPRemoteA | read-only | current | EDD Series card STP Port Statistics: Port2 -Received MSTP |
| 1.3.6.1.4.1.4756.20.441.20.1.698 | ColumneddSTPStatisticsPort2RxRSTPRemoteA | read-only | current | EDD Series card STP Port Statistics: Port1 -Received RSTP |
| 1.3.6.1.4.1.4756.20.441.20.1.699 | ColumneddSTPStatisticsPort2RxSTPRemoteA | read-only | current | EDD Series card STP Port Statistics: Port2 -Received RSTP |
| 1.3.6.1.4.1.4756.20.441.20.1.700 | ColumneddSTPStatisticsPort2RxTCNRemoteA | read-only | current | EDD Series card STP Port Statistics: Port2 -Received RSTP |
| 1.3.6.1.4.1.4756.20.441.20.1.701 | ColumneddSTPStatisticsPort2DiscardUnknowRemoteA | read-only | current | EDD Series card STP Port Statistics: Port2 -Discarded Unknown |
| 1.3.6.1.4.1.4756.20.441.20.1.702 | ColumneddSTPStatisticsPort2DiscardIllegalRemoteA | read-only | current | EDD Series card STP Port Statistics: Port2 -Discarded Illegal |
| 1.3.6.1.4.1.4756.20.441.20.1.703 | ColumneddSTPStatisticsPort3TxMSTPRemoteA | read-only | current | EDD Series card STP Port Statistics: Port3 -Transmitted MSTP |
| 1.3.6.1.4.1.4756.20.441.20.1.704 | ColumneddSTPStatisticsPort3TxRSTPRemoteA | read-only | current | EDD Series card STP Port Statistics: Port3 -Transmitted RSTP |
| 1.3.6.1.4.1.4756.20.441.20.1.705 | ColumneddSTPStatisticsPort3TxSTPRemoteA | read-only | current | EDD Series card STP Port Statistics: Port3 -Transmitted RSTP |
| 1.3.6.1.4.1.4756.20.441.20.1.706 | ColumneddSTPStatisticsPort3TxTCNRemoteA | read-only | current | EDD Series card STP Port Statistics: Port3 -Transmitted RSTP |
| 1.3.6.1.4.1.4756.20.441.20.1.707 | ColumneddSTPStatisticsPort3RxMSTPRemoteA | read-only | current | EDD Series card STP Port Statistics: Port3 -Received MSTP |
| 1.3.6.1.4.1.4756.20.441.20.1.708 | ColumneddSTPStatisticsPort3RxRSTPRemoteA | read-only | current | EDD Series card STP Port Statistics: Port3 -Received RSTP |
| 1.3.6.1.4.1.4756.20.441.20.1.709 | ColumneddSTPStatisticsPort3RxSTPRemoteA | read-only | current | EDD Series card STP Port Statistics: Port3 -Received RSTP |
| 1.3.6.1.4.1.4756.20.441.20.1.710 | ColumneddSTPStatisticsPort3RxTCNRemoteA | read-only | current | EDD Series card STP Port Statistics: Port3 -Received RSTP |
| 1.3.6.1.4.1.4756.20.441.20.1.711 | ColumneddSTPStatisticsPort3DiscardUnknowRemoteA | read-only | current | EDD Series card STP Port Statistics: Port3 -Discarded Unknown |
| 1.3.6.1.4.1.4756.20.441.20.1.712 | ColumneddSTPStatisticsPort3DiscardIllegalRemoteA | read-only | current | EDD Series card STP Port Statistics: Port3 -Discarded Illegal |
| 1.3.6.1.4.1.4756.20.441.20.1.713 | ColumneddSTPStatisticsPort4TxMSTPRemoteA | read-only | current | EDD Series card STP Port Statistics: Port4 -Transmitted MSTP |
| 1.3.6.1.4.1.4756.20.441.20.1.714 | ColumneddSTPStatisticsPort4TxRSTPRemoteA | read-only | current | EDD Series card STP Port Statistics: Port4 -Transmitted RSTP |
| 1.3.6.1.4.1.4756.20.441.20.1.715 | ColumneddSTPStatisticsPort4TxSTPRemoteA | read-only | current | EDD Series card STP Port Statistics: Port4 -Transmitted RSTP |
| 1.3.6.1.4.1.4756.20.441.20.1.716 | ColumneddSTPStatisticsPort4TxTCNRemoteA | read-only | current | EDD Series card STP Port Statistics: Port4 -Transmitted RSTP |
| 1.3.6.1.4.1.4756.20.441.20.1.717 | ColumneddSTPStatisticsPort4RxMSTPRemoteA | read-only | current | EDD Series card STP Port Statistics: Port4 -Received MSTP |
| 1.3.6.1.4.1.4756.20.441.20.1.718 | ColumneddSTPStatisticsPort4RxRSTPRemoteA | read-only | current | EDD Series card STP Port Statistics: Port4 -Received RSTP |
| 1.3.6.1.4.1.4756.20.441.20.1.719 | ColumneddSTPStatisticsPort4RxSTPRemoteA | read-only | current | EDD Series card STP Port Statistics: Port4 -Received RSTP |
| 1.3.6.1.4.1.4756.20.441.20.1.720 | ColumneddSTPStatisticsPort4RxTCNRemoteA | read-only | current | EDD Series card STP Port Statistics: Port4 -Received RSTP |
| 1.3.6.1.4.1.4756.20.441.20.1.721 | ColumneddSTPStatisticsPort4DiscardUnknowRemoteA | read-only | current | EDD Series card STP Port Statistics: Port4 -Discarded Unknown |
| 1.3.6.1.4.1.4756.20.441.20.1.722 | ColumneddSTPStatisticsPort4DiscardIllegalRemoteA | read-only | current | EDD Series card STP Port Statistics: Port4 -Discarded Illegal |
| 1.3.6.1.4.1.4756.20.441.20.1.723 | ColumneddSTPStatisticsPortClearCounterRemoteA | read-write | current | EDD Series card STP Port Statistics: Clear Counters 0: OFff 1: Action |
| 1.3.6.1.4.1.4756.20.441.20.1.724 | ColumneddAllowedAccessVLANsRemoteA | read-write | current | EDD Series card Global VLAN Configuration: Allowed Access VLANs By default, only VLAN 1 is enabled. More VLANs may be created by using a list syntax where the … |
| 1.3.6.1.4.1.4756.20.441.20.1.725 | ColumneddVlanEthertypeRemoteA | read-write | current | EDD Series card Global VLAN Configuration: Ethertype for Custom S-ports The format of 'Ethernet Type' is restricted to 0x600-0xFFFF |
| 1.3.6.1.4.1.4756.20.441.20.1.726 | ColumneddPort1VlanModeRemoteA | read-write | current | EDD Series card Port VLAN Configuration : Port1 - Mode 0: Access 1: Trunk 2: Hybrid |
| 1.3.6.1.4.1.4756.20.441.20.1.727 | ColumneddPort1VlanIDRemoteA | read-write | current | EDD Series card Port VLAN Configuration : Port1 - VLAN ID |
| 1.3.6.1.4.1.4756.20.441.20.1.728 | ColumneddPort1VlanTypeRemoteA | read-write | current | EDD Series card Port VLAN Configuration : Port1 - VLAN Type 0: Unaware 1: C-port 2: S-port 3: S-custom-port |
| 1.3.6.1.4.1.4756.20.441.20.1.729 | ColumneddPort1VlanIngressFilteringRemoteA | read-write | current | EDD Series card Port VLAN Configuration : Port1 - Ingress Filtering 0: Off 1: On |
| 1.3.6.1.4.1.4756.20.441.20.1.730 | ColumneddPort1VlanIngressAcceptanceRemoteA | read-write | current | EDD Series card Port VLAN Configuration : Port1 - Ingress Acceptance 0: Tagged and untagged 1: Tagged only 2: Untagged only |
| 1.3.6.1.4.1.4756.20.441.20.1.731 | ColumneddPort1VlanEgressTaggingRemoteA | read-write | current | EDD Series card Port VLAN Configuration : Port1 - Egress Tagging 0: Untag port vlan 1: Tag all 2: Untag all |
| 1.3.6.1.4.1.4756.20.441.20.1.732 | ColumneddPort1AllowedVLANSRemoteA | read-write | current | EDD Series card Global VLAN Configuration: Port1 - Allowed VLANs By default, only VLAN 1 is enabled. More VLANs may be created by using a list syntax where the… |
| 1.3.6.1.4.1.4756.20.441.20.1.733 | ColumneddPort1ForbiddenVLANSRemoteA | read-write | current | EDD Series card Global VLAN Configuration: Port1 - Forbidden VLANs By default, the field is left blank, which means that the port may become a member of all po… |
| 1.3.6.1.4.1.4756.20.441.20.1.734 | ColumneddPort2VlanModeRemoteA | read-write | current | EDD Series card Port VLAN Configuration : Port2 - Mode 0: Access 1: Trunk 2: Hybrid |
| 1.3.6.1.4.1.4756.20.441.20.1.735 | ColumneddPort2VlanIDRemoteA | read-write | current | EDD Series card Port VLAN Configuration : Port2 - VLAN ID |
| 1.3.6.1.4.1.4756.20.441.20.1.736 | ColumneddPort2VlanTypeRemoteA | read-write | current | EDD Series card Port VLAN Configuration : Port2 - VLAN Type 0: Unaware 1: C-port 2: S-port 3: S-custom-port |
| 1.3.6.1.4.1.4756.20.441.20.1.737 | ColumneddPort2VlanIngressFilteringRemoteA | read-write | current | EDD Series card Port VLAN Configuration : Port2 - Ingress Filtering 0: Off 1: On |
| 1.3.6.1.4.1.4756.20.441.20.1.738 | ColumneddPort2VlanIngressAcceptanceRemoteA | read-write | current | EDD Series card Port VLAN Configuration : Por2 - Ingress Acceptance 0: Tagged and untagged 1: Tagged only 2: Untagged only |
| 1.3.6.1.4.1.4756.20.441.20.1.739 | ColumneddPort2VlanEgressTaggingRemoteA | read-write | current | EDD Series card Port VLAN Configuration : Port2 - Egress Tagging 0: Untag port vlan 1: Tag all 2: Untag all |
| 1.3.6.1.4.1.4756.20.441.20.1.740 | ColumneddPort2AllowedVLANSRemoteA | read-write | current | EDD Series card Global VLAN Configuration: Port2 - Allowed VLANs By default, only VLAN 1 is enabled. More VLANs may be created by using a list syntax where the… |
| 1.3.6.1.4.1.4756.20.441.20.1.741 | ColumneddPort2ForbiddenVLANSRemoteA | read-write | current | EDD Series card Global VLAN Configuration: Port2 - Forbidden VLANs By default, the field is left blank, which means that the port may become a member of all po… |
| 1.3.6.1.4.1.4756.20.441.20.1.742 | ColumneddPort3VlanModeRemoteA | read-write | current | EDD Series card Port VLAN Configuration : Port3 - Mode 0: Access 1: Trunk 2: Hybrid |
| 1.3.6.1.4.1.4756.20.441.20.1.743 | ColumneddPort3VlanIDRemoteA | read-write | current | EDD Series card Port VLAN Configuration : Port3 - VLAN ID |
| 1.3.6.1.4.1.4756.20.441.20.1.744 | ColumneddPort3VlanTypeRemoteA | read-write | current | EDD Series card Port VLAN Configuration : Port3 - VLAN Type 0: Unaware 1: C-port 2: S-port 3: S-custom-port |
| 1.3.6.1.4.1.4756.20.441.20.1.745 | ColumneddPort3VlanIngressFilteringRemoteA | read-write | current | EDD Series card Port VLAN Configuration : Port3 - Ingress Filtering 0: Off 1: On |
| 1.3.6.1.4.1.4756.20.441.20.1.746 | ColumneddPort3VlanIngressAcceptanceRemoteA | read-write | current | EDD Series card Port VLAN Configuration : Port3 - Ingress Acceptance 0: Tagged and untagged 1: Tagged only 2: Untagged only |
| 1.3.6.1.4.1.4756.20.441.20.1.747 | ColumneddPort3VlanEgressTaggingRemoteA | read-write | current | EDD Series card Port VLAN Configuration : Port3 - Egress Tagging 0: Untag port vlan 1: Tag all 2: Untag all |
| 1.3.6.1.4.1.4756.20.441.20.1.748 | ColumneddPort3AllowedVLANSRemoteA | read-write | current | EDD Series card Global VLAN Configuration: Port3 - Allowed VLANs By default, only VLAN 1 is enabled. More VLANs may be created by using a list syntax where the… |
| 1.3.6.1.4.1.4756.20.441.20.1.749 | ColumneddPort3ForbiddenVLANSRemoteA | read-write | current | EDD Series card Global VLAN Configuration: Port3 - Forbidden VLANs By default, the field is left blank, which means that the port may become a member of all po… |
| 1.3.6.1.4.1.4756.20.441.20.1.750 | ColumneddPort4VlanModeRemoteA | read-write | current | EDD Series card Port VLAN Configuration : Port4 - Mode 0: Access 1: Trunk 2: Hybrid |
| 1.3.6.1.4.1.4756.20.441.20.1.751 | ColumneddPort4VlanIDRemoteA | read-write | current | EDD Series card Port VLAN Configuration : Port4 - VLAN ID |
| 1.3.6.1.4.1.4756.20.441.20.1.752 | ColumneddPort4VlanTypeRemoteA | read-write | current | EDD Series card Port VLAN Configuration : Port4 - VLAN Type 0: Unaware 1: C-port 2: S-port 3: S-custom-port |
| 1.3.6.1.4.1.4756.20.441.20.1.753 | ColumneddPort4VlanIngressFilteringRemoteA | read-write | current | EDD Series card Port VLAN Configuration : Port4 - Ingress Filtering 0: Off 1: On |
| 1.3.6.1.4.1.4756.20.441.20.1.754 | ColumneddPort4VlanIngressAcceptanceRemoteA | read-write | current | EDD Series card Port VLAN Configuration : Port4 - Ingress Acceptance 0: Tagged and untagged 1: Tagged only 2: Untagged only |
| 1.3.6.1.4.1.4756.20.441.20.1.755 | ColumneddPort4VlanEgressTaggingRemoteA | read-write | current | EDD Series card Port VLAN Configuration : Port4 - Egress Tagging 0: Untag port vlan 1: Tag all 2: Untag all |
| 1.3.6.1.4.1.4756.20.441.20.1.756 | ColumneddPort4AllowedVLANSRemoteA | read-write | current | EDD Series card Global VLAN Configuration: Port4 - Allowed VLANs By default, only VLAN 1 is enabled. More VLANs may be created by using a list syntax where the… |
| 1.3.6.1.4.1.4756.20.441.20.1.757 | ColumneddPort4ForbiddenVLANSRemoteA | read-write | current | EDD Series card Global VLAN Configuration: Port4 - Forbidden VLANs By default, the field is left blank, which means that the port may become a member of all po… |
| 1.3.6.1.4.1.4756.20.441.20.1.758 | ColumneddDNSServerTypeRemoteA | read-write | current | EDD Series card IP Configuration: This setting controls the DNS name resolution done by the switch. The following modes are supported: 1:From any DHCP interfac… |
| 1.3.6.1.4.1.4756.20.441.20.1.759 | ColumneddDNSServerSettingRemoteA | read-write | current | EDD Series card IP Configuration: If iDNSServerType setting '3:Configured',this value must setting IP address format as below: Dotted Decimal Notation refers t… |
| 1.3.6.1.4.1.4756.20.441.20.1.760 | ColumneddDNSproxyRemoteA | read-write | current | EDD Series card IP Configuration: When DNS proxy is enabled, system will relay DNS requests to the currently configured DNS server, and reply as a DNS resolver… |
| 1.3.6.1.4.1.4756.20.441.20.1.761 | ColumneddAddIPV4InterfaceRemoteA | read-write | current | EDD Series card IP Interfaces: Add a new IP VLAN Interface: Syntax: [<Interface>] [<vlan_list>] [<IPV4_Addr>] [<IPV4_MASK>] Interface : 1~4 |
| 1.3.6.1.4.1.4756.20.441.20.1.762 | ColumneddDeleteInterfaceRemoteA | read-write | current | EDD Series card IP Interfaces: Delete a IPv4/v6 VLAN Interface: Syntax: [<Interface>] Interface: 1~4 |
| 1.3.6.1.4.1.4756.20.441.20.1.763 | ColumneddIPInterface1VLANRemoteA | read-only | current | EDD Series card IP Interfaces: The VLAN associated with the IP interface. Only ports in this VLAN will be able to access the IP interface. This field is only a… |
| 1.3.6.1.4.1.4756.20.441.20.1.764 | ColumneddIPInterface1DHCPRemoteA | read-write | current | EDD Series card IP Interfaces: DHCP |
| 1.3.6.1.4.1.4756.20.441.20.1.765 | ColumneddIPInterface1FallbackRemoteA | read-write | current | EDD Series card IP Interfaces: Fallback |
| 1.3.6.1.4.1.4756.20.441.20.1.766 | ColumneddIPInterface1IPV4AddressRemoteA | read-only | current | EDD Series card IP Interfaces: IPV4 Address |
| 1.3.6.1.4.1.4756.20.441.20.1.767 | ColumneddIPInterface1IPV4MASKLenRemoteA | read-only | current | EDD Series card IP Interfaces: IPV4 MASK Length |
| 1.3.6.1.4.1.4756.20.441.20.1.768 | ColumneddIPInterface2VLANRemoteA | read-only | current | EDD Series card IP Interfaces: The VLAN associated with the IP interface. Only ports in this VLAN will be able to access the IP interface. This field is only a… |
| 1.3.6.1.4.1.4756.20.441.20.1.769 | ColumneddIPInterface2DHCPRemoteA | read-write | current | EDD Series card IP Interfaces: DHCP |
| 1.3.6.1.4.1.4756.20.441.20.1.770 | ColumneddIPInterface2FallbackRemoteA | read-write | current | EDD Series card IP Interfaces: Fallback |
| 1.3.6.1.4.1.4756.20.441.20.1.771 | ColumneddIPInterface2IPV4AddressRemoteA | read-only | current | EDD Series card IP Interfaces: IPV4 Address |
| 1.3.6.1.4.1.4756.20.441.20.1.772 | ColumneddIPInterface2IPV4MASKLenRemoteA | read-only | current | EDD Series card IP Interfaces: IPV4 MASK Length |
| 1.3.6.1.4.1.4756.20.441.20.1.773 | ColumneddIPInterface3VLANRemoteA | read-only | current | EDD Series card IP Interfaces: The VLAN associated with the IP interface. Only ports in this VLAN will be able to access the IP interface. This field is only a… |
| 1.3.6.1.4.1.4756.20.441.20.1.774 | ColumneddIPInterface3DHCPRemoteA | read-write | current | EDD Series card IP Interfaces: DHCP |
| 1.3.6.1.4.1.4756.20.441.20.1.775 | ColumneddIPInterface3FallbackRemoteA | read-write | current | EDD Series card IP Interfaces: Fallback |
| 1.3.6.1.4.1.4756.20.441.20.1.776 | ColumneddIPInterface3IPV4AddressRemoteA | read-only | current | EDD Series card IP Interfaces: IPV4 Address |
| 1.3.6.1.4.1.4756.20.441.20.1.777 | ColumneddIPInterface3IPV4MASKLenRemoteA | read-only | current | EDD Series card IP Interfaces: IPV4 MASK Length |
| 1.3.6.1.4.1.4756.20.441.20.1.778 | ColumneddIPInterface4VLANRemoteA | read-only | current | EDD Series card IP Interfaces: The VLAN associated with the IP interface. Only ports in this VLAN will be able to access the IP interface. This field is only a… |
| 1.3.6.1.4.1.4756.20.441.20.1.779 | ColumneddIPInterface4DHCPRemoteA | read-write | current | EDD Series card IP Interfaces: DHCP |
| 1.3.6.1.4.1.4756.20.441.20.1.780 | ColumneddIPInterface4FallbackRemoteA | read-write | current | EDD Series card IP Interfaces: Fallback |
| 1.3.6.1.4.1.4756.20.441.20.1.781 | ColumneddIPInterface4IPV4AddressRemoteA | read-only | current | EDD Series card IP Interfaces: IPV4 Address |
| 1.3.6.1.4.1.4756.20.441.20.1.782 | ColumneddIPInterface4IPV4MASKLenRemoteA | read-only | current | EDD Series card IP Interfaces: IPV4 MASK Length |
| 1.3.6.1.4.1.4756.20.441.20.1.783 | ColumneddAddIPV6InterfaceRemoteA | read-write | current | EDD Series card IP Interfaces: Add a new IPv6 VLAN Interface: Syntax: [<Interface>] [<vlan_list>] [<IPV4_Addr>] [<IPV4_MASK>] Interface : 1~4 |
| 1.3.6.1.4.1.4756.20.441.20.1.784 | ColumneddIPInterface1IPV6AddressRemoteA | read-only | current | EDD Series card IP Interfaces: IPV6 Address |
| 1.3.6.1.4.1.4756.20.441.20.1.785 | ColumneddIPInterface1IPV6MASKLenRemoteA | read-only | current | EDD Series card IP Interfaces: IPV6 MASK Length |
| 1.3.6.1.4.1.4756.20.441.20.1.786 | ColumneddIPInterface2IPV6AddressRemoteA | read-only | current | EDD Series card IP Interfaces: IPV6 Address |
| 1.3.6.1.4.1.4756.20.441.20.1.787 | ColumneddIPInterface2IPV6MASKLenRemoteA | read-only | current | EDD Series card IP Interfaces: IPV6 MASK Length |
| 1.3.6.1.4.1.4756.20.441.20.1.788 | ColumneddIPInterface3IPV6AddressRemoteA | read-only | current | EDD Series card IP Interfaces: IPV6 Address |
| 1.3.6.1.4.1.4756.20.441.20.1.789 | ColumneddIPInterface3IPV6MASKLenRemoteA | read-only | current | EDD Series card IP Interfaces: IPV6 MASK Length |
| 1.3.6.1.4.1.4756.20.441.20.1.790 | ColumneddIPInterface4IPV6AddressRemoteA | read-only | current | EDD Series card IP Interfaces: IPV6 Address |
| 1.3.6.1.4.1.4756.20.441.20.1.791 | ColumneddIPInterface4IPV6MASKLenRemoteA | read-only | current | EDD Series card IP Interfaces: IPV6 MASK Length |
| 1.3.6.1.4.1.4756.20.441.20.1.792 | ColumneddPort1ALSRemoteA | read-write | current | EDD Series card Port1 auto laser shutdown: 0: Disable 1: Enable |
| 1.3.6.1.4.1.4756.20.441.20.1.793 | ColumneddPort2ALSRemoteA | read-write | current | EDD Series card Port2 auto laser shutdown: 0: Disable 1: Enable |
| 1.3.6.1.4.1.4756.20.441.20.1.794 | ColumneddPort3ALSRemoteA | read-write | current | EDD Series card Port3 auto laser shutdown (MX210 only): 0: Disable 1: Enable |
| 1.3.6.1.4.1.4756.20.441.20.1.795 | ColumneddPort1LLFLogicRemoteA | read-write | current | EDD Series card Port1 link loss forwarding - Logic 0: AND 1: OR |
| 1.3.6.1.4.1.4756.20.441.20.1.796 | ColumneddPort1LLFLogicPort2RemoteA | read-write | current | EDD Series card Port1 link loss forwarding - Link/Rx Loss Port2 0: NO 1: YES |
| 1.3.6.1.4.1.4756.20.441.20.1.797 | ColumneddPort1LLFLogicPort3RemoteA | read-write | current | EDD Series card Port1 link loss forwarding - Link/Rx Loss Port3 0: NO 1: YES |
| 1.3.6.1.4.1.4756.20.441.20.1.798 | ColumneddPort1LLFLogicPort4RemoteA | read-write | current | EDD Series card Port1 link loss forwarding - Link/Rx Loss Port4 0: NO 1: YES |
| 1.3.6.1.4.1.4756.20.441.20.1.799 | ColumneddPort2LLFLogicRemoteA | read-write | current | EDD Series card Port2 link loss forwarding - Logic 0: AND 1: OR |
| 1.3.6.1.4.1.4756.20.441.20.1.800 | ColumneddPort2LLFLogicPort1RemoteA | read-write | current | EDD Series card Port2 link loss forwarding - Link/Rx Loss Port1 0: NO 1: YES |
| 1.3.6.1.4.1.4756.20.441.20.1.801 | ColumneddPort2LLFLogicPort3RemoteA | read-write | current | EDD Series card Port2 link loss forwarding - Link/Rx Loss Port3 0: NO 1: YES |
| 1.3.6.1.4.1.4756.20.441.20.1.802 | ColumneddPort2LLFLogicPort4RemoteA | read-write | current | EDD Series card Port2 link loss forwarding - Link/Rx Loss Port4 0: NO 1: YES |
| 1.3.6.1.4.1.4756.20.441.20.1.803 | ColumneddPort3LLFLogicRemoteA | read-write | current | EDD Series card Port1 link loss forwarding - Logic 0: AND 1: OR |
| 1.3.6.1.4.1.4756.20.441.20.1.804 | ColumneddPort3LLFLogicPort1RemoteA | read-write | current | EDD Series card Port3 link loss forwarding - Link/Rx Loss Port1 0: NO 1: YES |
| 1.3.6.1.4.1.4756.20.441.20.1.805 | ColumneddPort3LLFLogicPort2RemoteA | read-write | current | EDD Series card Port3 link loss forwarding - Link/Rx Loss Port2 0: NO 1: YES |
| 1.3.6.1.4.1.4756.20.441.20.1.806 | ColumneddPort3LLFLogicPort4RemoteA | read-write | current | EDD Series card Port3 link loss forwarding - Link/Rx Loss Port4 0: NO 1: YES |
| 1.3.6.1.4.1.4756.20.441.20.1.807 | ColumneddPort4LLFLogicRemoteA | read-write | current | EDD Series card Port4 link loss forwarding - Logic 0: AND 1: OR |
| 1.3.6.1.4.1.4756.20.441.20.1.808 | ColumneddPort4LLFLogicPort1RemoteA | read-write | current | EDD Series card Port4 link loss forwarding - Link/Rx Loss Port1 0: NO 1: YES |
| 1.3.6.1.4.1.4756.20.441.20.1.809 | ColumneddPort4LLFLogicPort2RemoteA | read-write | current | EDD Series card Port4 link loss forwarding - Link/Rx Loss Port2 0: NO 1: YES |
| 1.3.6.1.4.1.4756.20.441.20.1.810 | ColumneddPort4LLFLogicPort3RemoteA | read-write | current | EDD Series card Port4 link loss forwarding - Link/Rx Loss Port3 0: NO 1: YES |
| 1.3.6.1.4.1.4756.20.441.20.1.811 | ColumneddQOSPort1IngressRemoteA | read-write | current | EDD Series card QOS Port1 Ingress Enabled 0: NO 1: YES |
| 1.3.6.1.4.1.4756.20.441.20.1.812 | ColumneddQOSPort1IngressRateRemoteA | read-write | current | EDD Series card QOS Port1 Ingress Rate |
| 1.3.6.1.4.1.4756.20.441.20.1.813 | ColumneddQOSPort1IngressRateUnitRemoteA | read-write | current | EDD Series card QOS Port1 Ingress Rate Unit 0: Kbps 1: Mbps 2: fps 3: kfps |
| 1.3.6.1.4.1.4756.20.441.20.1.814 | ColumneddQOSPort1IngressFlowControlRemoteA | read-write | current | EDD Series card QOS Port1 Ingress Flow Control 0: NO 1: YES |
| 1.3.6.1.4.1.4756.20.441.20.1.815 | ColumneddQOSPort2IngressRemoteA | read-write | current | EDD Series card QOS Port2 Ingress Enabled 0: NO 1: YES |
| 1.3.6.1.4.1.4756.20.441.20.1.816 | ColumneddQOSPort2IngressRateRemoteA | read-write | current | EDD Series card QOS Port2 Ingress Rate |
| 1.3.6.1.4.1.4756.20.441.20.1.817 | ColumneddQOSPort2IngressRateUnitRemoteA | read-write | current | EDD Series card QOS Port2 Ingress Rate Unit 0: Kbps 1: Mbps 2: fps 3: kfps |
| 1.3.6.1.4.1.4756.20.441.20.1.818 | ColumneddQOSPort2IngressFlowControlRemoteA | read-write | current | EDD Series card QOS Port2 Ingress Flow Control 0: NO 1: YES |
| 1.3.6.1.4.1.4756.20.441.20.1.819 | ColumneddQOSPort3IngressRemoteA | read-write | current | EDD Series card QOS Port3 Ingress Enabled 0: NO 1: YES |
| 1.3.6.1.4.1.4756.20.441.20.1.820 | ColumneddQOSPort3IngressRateRemoteA | read-write | current | EDD Series card QOS Port3 Ingress Rate |
| 1.3.6.1.4.1.4756.20.441.20.1.821 | ColumneddQOSPort3IngressRateUnitRemoteA | read-write | current | EDD Series card QOS Port3 Ingress Rate Unit 0: Kbps 1: Mbps 2: fps 3: kfps |
| 1.3.6.1.4.1.4756.20.441.20.1.822 | ColumneddQOSPort3IngressFlowControlRemoteA | read-write | current | EDD Series card QOS Port3 Ingress Flow Control 0: NO 1: YES |
| 1.3.6.1.4.1.4756.20.441.20.1.823 | ColumneddQOSPort4IngressRemoteA | read-write | current | EDD Series card QOS Port4 Ingress Enabled 0: NO 1: YES |
| 1.3.6.1.4.1.4756.20.441.20.1.824 | ColumneddQOSPort4IngressRateRemoteA | read-write | current | EDD Series card QOS Port4 Ingress Rate |
| 1.3.6.1.4.1.4756.20.441.20.1.825 | ColumneddQOSPort4IngressRateUnitRemoteA | read-write | current | EDD Series card QOS Port4 Ingress Rate Unit 0: Kbps 1: Mbps 2: fps 3: kfps |
| 1.3.6.1.4.1.4756.20.441.20.1.826 | ColumneddQOSPort4IngressFlowControlRemoteA | read-write | current | EDD Series card QOS Port4 Ingress Flow Control 0: NO 1: YES |
| 1.3.6.1.4.1.4756.20.441.20.1.827 | ColumneddQOSPort1EgressRemoteA | read-write | current | EDD Series card QOS Port1 Egress Enabled 0: NO 1: YES |
| 1.3.6.1.4.1.4756.20.441.20.1.828 | ColumneddQOSPort1EgressRateRemoteA | read-write | current | EDD Series card QOS Port1 Egress Rate |
| 1.3.6.1.4.1.4756.20.441.20.1.829 | ColumneddQOSPort1EgressRateUnitRemoteA | read-write | current | EDD Series card QOS Port1 Egress Rate Unit 0: Kbps 1: Mbps |
| 1.3.6.1.4.1.4756.20.441.20.1.830 | ColumneddQOSPort2EgressRemoteA | read-write | current | EDD Series card QOS Port2 Egress Enabled 0: NO 1: YES |
| 1.3.6.1.4.1.4756.20.441.20.1.831 | ColumneddQOSPort2EgressRateRemoteA | read-write | current | EDD Series card QOS Port2 Egress Rate |
| 1.3.6.1.4.1.4756.20.441.20.1.832 | ColumneddQOSPort2EgressRateUnitRemoteA | read-write | current | EDD Series card QOS Port2 Egress Rate Unit 0: Kbps 1: Mbps |
| 1.3.6.1.4.1.4756.20.441.20.1.833 | ColumneddQOSPort3EgressRemoteA | read-write | current | EDD Series card QOS Port3 Egress Enabled 0: NO 1: YES |
| 1.3.6.1.4.1.4756.20.441.20.1.834 | ColumneddQOSPort3EgressRateRemoteA | read-write | current | EDD Series card QOS Port3 Egress Rate |
| 1.3.6.1.4.1.4756.20.441.20.1.835 | ColumneddQOSPort3EgressRateUnitRemoteA | read-write | current | EDD Series card QOS Port3 Egress Rate Unit 0: Kbps 1: Mbps |
| 1.3.6.1.4.1.4756.20.441.20.1.836 | ColumneddQOSPort4EgressRemoteA | read-write | current | EDD Series card QOS Port4 Egress Enabled 0: NO 1: YES |
| 1.3.6.1.4.1.4756.20.441.20.1.837 | ColumneddQOSPort4EgressRateRemoteA | read-write | current | EDD Series card QOS Port4 Egress Rate |
| 1.3.6.1.4.1.4756.20.441.20.1.838 | ColumneddQOSPort4EgressRateUnitRemoteA | read-write | current | EDD Series card QOS Port4 Egress Rate Unit 0: Kbps 1: Mbps |
| 1.3.6.1.4.1.4756.20.441.20.1.839 | ColumneddQOSUnicastRemoteA | read-write | current | EDD Series card QOS Storm Control Configuration- Unicast 0: NO 1: YES |
| 1.3.6.1.4.1.4756.20.441.20.1.840 | ColumneddQOSUnicastRateRemoteA | read-write | current | EDD Series card QOS Storm Control Configuration- Unicast Rate The rate unit is packets per second (pps). 0: 1 1: 2 2: 4 3: 8 4: 16 5: 32 6: 64 7: 128 8: 256 9:… |
| 1.3.6.1.4.1.4756.20.441.20.1.841 | ColumneddQOSMulticastRemoteA | read-write | current | EDD Series card QOS Storm Control Configuration- Multicast 0: NO 1: YES |
| 1.3.6.1.4.1.4756.20.441.20.1.842 | ColumneddQOSMulticastRateRemoteA | read-write | current | EDD Series card QOS Storm Control Configuration- Multicast The rate unit is packets per second (pps). 0: 1 1: 2 2: 4 3: 8 4: 16 5: 32 6: 64 7: 128 8: 256 9: 51… |
| 1.3.6.1.4.1.4756.20.441.20.1.843 | ColumneddQOSBroadcastRemoteA | read-write | current | EDD Series card QOS Storm Control Configuration- Broadcast 0: NO 1: YES |
| 1.3.6.1.4.1.4756.20.441.20.1.844 | ColumneddQOSBroadcastRateRemoteA | read-write | current | EDD Series card QOS Storm Control Configuration- Broadcast The rate unit is packets per second (pps). 0: 1 1: 2 2: 4 3: 8 4: 16 5: 32 6: 64 7: 128 8: 256 9: 51… |
| 1.3.6.1.4.1.4756.20.441.20.1.845 | ColumneddL2CPPort1DMAC0180C2000000RemoteA | read-write | current | EDD Series card Port 1 L2CP Mode 0180C2000000 0: Forward 1: Peer |
| 1.3.6.1.4.1.4756.20.441.20.1.846 | ColumneddL2CPPort1DMAC0180C2000001RemoteA | read-write | current | EDD Series card Port 1 L2CP Mode 0180C2000001 0: Forward 1: Peer |
| 1.3.6.1.4.1.4756.20.441.20.1.847 | ColumneddL2CPPort1DMAC0180C2000002RemoteA | read-write | current | EDD Series card Port 1 L2CP Mode 0180C2000002 0: Forward 1: Peer |
| 1.3.6.1.4.1.4756.20.441.20.1.848 | ColumneddL2CPPort1DMAC0180C2000003RemoteA | read-write | current | EDD Series card Port 1 L2CP Mode 0180C2000003 0: Forward 1: Peer |
| 1.3.6.1.4.1.4756.20.441.20.1.849 | ColumneddL2CPPort1DMAC0180C2000004RemoteA | read-write | current | EDD Series card Port 1 L2CP Mode 0180C2000004 0: Forward 1: Peer |
| 1.3.6.1.4.1.4756.20.441.20.1.850 | ColumneddL2CPPort1DMAC0180C2000005RemoteA | read-write | current | EDD Series card Port 1 L2CP Mode 0180C2000005 0: Forward 1: Peer |
| 1.3.6.1.4.1.4756.20.441.20.1.851 | ColumneddL2CPPort1DMAC0180C2000006RemoteA | read-write | current | EDD Series card Port 1 L2CP Mode 0180C2000006 0: Forward 1: Peer |
| 1.3.6.1.4.1.4756.20.441.20.1.852 | ColumneddL2CPPort1DMAC0180C2000007RemoteA | read-write | current | EDD Series card Port 1 L2CP Mode 0180C2000007 0: Forward 1: Peer |
| 1.3.6.1.4.1.4756.20.441.20.1.853 | ColumneddL2CPPort1DMAC0180C2000008RemoteA | read-write | current | EDD Series card Port 1 L2CP Mode 0180C2000008 0: Forward 1: Peer |
| 1.3.6.1.4.1.4756.20.441.20.1.854 | ColumneddL2CPPort1DMAC0180C2000009RemoteA | read-write | current | EDD Series card Port 1 L2CP Mode 0180C2000009 0: Forward 1: Peer |
| 1.3.6.1.4.1.4756.20.441.20.1.855 | ColumneddL2CPPort1DMAC0180C200000ARemoteA | read-write | current | EDD Series card Port 1 L2CP Mode 0180C200000A 0: Forward 1: Peer |
| 1.3.6.1.4.1.4756.20.441.20.1.856 | ColumneddL2CPPort1DMAC0180C200000BRemoteA | read-write | current | EDD Series card Port 1 L2CP Mode 0180C200000B 0: Forward 1: Peer |
| 1.3.6.1.4.1.4756.20.441.20.1.857 | ColumneddL2CPPort1DMAC0180C200000CRemoteA | read-write | current | EDD Series card Port 1 L2CP Mode 0180C200000C 0: Forward 1: Peer |
| 1.3.6.1.4.1.4756.20.441.20.1.858 | ColumneddL2CPPort1DMAC0180C200000DRemoteA | read-write | current | EDD Series card Port 1 L2CP Mode 0180C200000D 0: Forward 1: Peer |
| 1.3.6.1.4.1.4756.20.441.20.1.859 | ColumneddL2CPPort1DMAC0180C200000ERemoteA | read-write | current | EDD Series card Port 1 L2CP Mode 0180C200000E 0: Forward 1: Peer |
| 1.3.6.1.4.1.4756.20.441.20.1.860 | ColumneddL2CPPort1DMAC0180C200000FRemoteA | read-write | current | EDD Series card Port 1 L2CP Mode 0180C200000F 0: Forward 1: Peer |
| 1.3.6.1.4.1.4756.20.441.20.1.861 | ColumneddL2CPPort1DMAC0180C2000010RemoteA | read-write | current | EDD Series card Port 1 L2CP Mode 0180C2000010 0: Forward 1: Peer |
| 1.3.6.1.4.1.4756.20.441.20.1.862 | ColumneddL2CPPort1DMAC0180C2000020RemoteA | read-write | current | EDD Series card Port 1 L2CP Mode 0180C2000020 0: Forward 1: Peer |
| 1.3.6.1.4.1.4756.20.441.20.1.863 | ColumneddL2CPPort1DMAC0180C2000021RemoteA | read-write | current | EDD Series card Port 1 L2CP Mode 0180C2000021 0: Forward 1: Peer |
| 1.3.6.1.4.1.4756.20.441.20.1.864 | ColumneddL2CPPort1DMAC0180C2000022RemoteA | read-write | current | EDD Series card Port 1 L2CP Mode 0180C2000022 0: Forward 1: Peer |
| 1.3.6.1.4.1.4756.20.441.20.1.865 | ColumneddL2CPPort1DMAC0180C2000023RemoteA | read-write | current | EDD Series card Port 1 L2CP Mode 0180C2000023 0: Forward 1: Peer |
| 1.3.6.1.4.1.4756.20.441.20.1.866 | ColumneddL2CPPort1DMAC0180C2000024RemoteA | read-write | current | EDD Series card Port 1 L2CP Mode 0180C2000024 0: Forward 1: Peer |
| 1.3.6.1.4.1.4756.20.441.20.1.867 | ColumneddL2CPPort1DMAC0180C2000025RemoteA | read-write | current | EDD Series card Port 1 L2CP Mode 0180C2000025 0: Forward 1: Peer |
| 1.3.6.1.4.1.4756.20.441.20.1.868 | ColumneddL2CPPort1DMAC0180C2000026RemoteA | read-write | current | EDD Series card Port 1 L2CP Mode 0180C2000026 0: Forward 1: Peer |
| 1.3.6.1.4.1.4756.20.441.20.1.869 | ColumneddL2CPPort1DMAC0180C2000027RemoteA | read-write | current | EDD Series card Port 1 L2CP Mode 0180C2000027 0: Forward 1: Peer |
| 1.3.6.1.4.1.4756.20.441.20.1.870 | ColumneddL2CPPort1DMAC0180C2000028RemoteA | read-write | current | EDD Series card Port 1 L2CP Mode 0180C2000028 0: Forward 1: Peer |
| 1.3.6.1.4.1.4756.20.441.20.1.871 | ColumneddL2CPPort1DMAC0180C2000029RemoteA | read-write | current | EDD Series card Port 1 L2CP Mode 0180C2000029 0: Forward 1: Peer |
| 1.3.6.1.4.1.4756.20.441.20.1.872 | ColumneddL2CPPort1DMAC0180C200002ARemoteA | read-write | current | EDD Series card Port 1 L2CP Mode 0180C200002A 0: Forward 1: Peer |
| 1.3.6.1.4.1.4756.20.441.20.1.873 | ColumneddL2CPPort1DMAC0180C200002BRemoteA | read-write | current | EDD Series card Port 1 L2CP Mode 0180C200002B 0: Forward 1: Peer |
| 1.3.6.1.4.1.4756.20.441.20.1.874 | ColumneddL2CPPort1DMAC0180C200002CRemoteA | read-write | current | EDD Series card Port 1 L2CP Mode 0180C200002C 0: Forward 1: Peer |
| 1.3.6.1.4.1.4756.20.441.20.1.875 | ColumneddL2CPPort1DMAC0180C200002DRemoteA | read-write | current | EDD Series card Port 1 L2CP Mode 0180C200002D 0: Forward 1: Peer |
| 1.3.6.1.4.1.4756.20.441.20.1.876 | ColumneddL2CPPort1DMAC0180C200002ERemoteA | read-write | current | EDD Series card Port 1 L2CP Mode 0180C200002E 0: Forward 1: Peer |
| 1.3.6.1.4.1.4756.20.441.20.1.877 | ColumneddL2CPPort1DMAC0180C200002FRemoteA | read-write | current | EDD Series card Port 1 L2CP Mode 0180C200002F 0: Forward 1: Peer |
| 1.3.6.1.4.1.4756.20.441.20.1.878 | ColumneddL2CPPort2DMAC0180C2000000RemoteA | read-write | current | EDD Series card Port 2 L2CP Mode 0180C2000000 0: Forward 1: Peer |
| 1.3.6.1.4.1.4756.20.441.20.1.879 | ColumneddL2CPPort2DMAC0180C2000001RemoteA | read-write | current | EDD Series card Port 2 L2CP Mode 0180C2000001 0: Forward 1: Peer |
| 1.3.6.1.4.1.4756.20.441.20.1.880 | ColumneddL2CPPort2DMAC0180C2000002RemoteA | read-write | current | EDD Series card Port 2 L2CP Mode 0180C2000002 0: Forward 1: Peer |
| 1.3.6.1.4.1.4756.20.441.20.1.881 | ColumneddL2CPPort2DMAC0180C2000003RemoteA | read-write | current | EDD Series card Port 2 L2CP Mode 0180C2000003 0: Forward 1: Peer |
| 1.3.6.1.4.1.4756.20.441.20.1.882 | ColumneddL2CPPort2DMAC0180C2000004RemoteA | read-write | current | EDD Series card Port 2 L2CP Mode 0180C2000004 0: Forward 1: Peer |
| 1.3.6.1.4.1.4756.20.441.20.1.883 | ColumneddL2CPPort2DMAC0180C2000005RemoteA | read-write | current | EDD Series card Port 2 L2CP Mode 0180C2000005 0: Forward 1: Peer |
| 1.3.6.1.4.1.4756.20.441.20.1.884 | ColumneddL2CPPort2DMAC0180C2000006RemoteA | read-write | current | EDD Series card Port 2 L2CP Mode 0180C2000006 0: Forward 1: Peer |
| 1.3.6.1.4.1.4756.20.441.20.1.885 | ColumneddL2CPPort2DMAC0180C2000007RemoteA | read-write | current | EDD Series card Port 2 L2CP Mode 0180C2000007 0: Forward 1: Peer |
| 1.3.6.1.4.1.4756.20.441.20.1.886 | ColumneddL2CPPort2DMAC0180C2000008RemoteA | read-write | current | EDD Series card Port 2 L2CP Mode 0180C2000008 0: Forward 1: Peer |
| 1.3.6.1.4.1.4756.20.441.20.1.887 | ColumneddL2CPPort2DMAC0180C2000009RemoteA | read-write | current | EDD Series card Port 2 L2CP Mode 0180C2000009 0: Forward 1: Peer |
| 1.3.6.1.4.1.4756.20.441.20.1.888 | ColumneddL2CPPort2DMAC0180C200000ARemoteA | read-write | current | EDD Series card Port 2 L2CP Mode 0180C200000A 0: Forward 1: Peer |
| 1.3.6.1.4.1.4756.20.441.20.1.889 | ColumneddL2CPPort2DMAC0180C200000BRemoteA | read-write | current | EDD Series card Port 2 L2CP Mode 0180C200000B 0: Forward 1: Peer |
| 1.3.6.1.4.1.4756.20.441.20.1.890 | ColumneddL2CPPort2DMAC0180C200000CRemoteA | read-write | current | EDD Series card Port 2 L2CP Mode 0180C200000C 0: Forward 1: Peer |
| 1.3.6.1.4.1.4756.20.441.20.1.891 | ColumneddL2CPPort2DMAC0180C200000DRemoteA | read-write | current | EDD Series card Port 2 L2CP Mode 0180C200000A 0: Forward 1: Peer |
| 1.3.6.1.4.1.4756.20.441.20.1.892 | ColumneddL2CPPort2DMAC0180C200000ERemoteA | read-write | current | EDD Series card Port 2 L2CP Mode 0180C200000E 0: Forward 1: Peer |
| 1.3.6.1.4.1.4756.20.441.20.1.893 | ColumneddL2CPPort2DMAC0180C200000FRemoteA | read-write | current | EDD Series card Port 2 L2CP Mode 0180C200000F 0: Forward 1: Peer |
| 1.3.6.1.4.1.4756.20.441.20.1.894 | ColumneddL2CPPort2DMAC0180C2000010RemoteA | read-write | current | EDD Series card Port 2 L2CP Mode 0180C2000010 0: Forward 1: Peer |
| 1.3.6.1.4.1.4756.20.441.20.1.895 | ColumneddL2CPPort2DMAC0180C2000020RemoteA | read-write | current | EDD Series card Port 2 L2CP Mode 0180C2000020 0: Forward 1: Peer |
| 1.3.6.1.4.1.4756.20.441.20.1.896 | ColumneddL2CPPort2DMAC0180C2000021RemoteA | read-write | current | EDD Series card Port 2 L2CP Mode 0180C2000021 0: Forward 1: Peer |
| 1.3.6.1.4.1.4756.20.441.20.1.897 | ColumneddL2CPPort2DMAC0180C2000022RemoteA | read-write | current | EDD Series card Port 2 L2CP Mode 0180C2000022 0: Forward 1: Peer |
| 1.3.6.1.4.1.4756.20.441.20.1.898 | ColumneddL2CPPort2DMAC0180C2000023RemoteA | read-write | current | EDD Series card Port 2 L2CP Mode 0180C2000023 0: Forward 1: Peer |
| 1.3.6.1.4.1.4756.20.441.20.1.899 | ColumneddL2CPPort2DMAC0180C2000024RemoteA | read-write | current | EDD Series card Port 2 L2CP Mode 0180C2000024 0: Forward 1: Peer |
| 1.3.6.1.4.1.4756.20.441.20.1.900 | ColumneddL2CPPort2DMAC0180C2000025RemoteA | read-write | current | EDD Series card Port 2 L2CP Mode 0180C2000025 0: Forward 1: Peer |
| 1.3.6.1.4.1.4756.20.441.20.1.901 | ColumneddL2CPPort2DMAC0180C2000026RemoteA | read-write | current | EDD Series card Port 2 L2CP Mode 0180C2000026 0: Forward 1: Peer |
| 1.3.6.1.4.1.4756.20.441.20.1.902 | ColumneddL2CPPort2DMAC0180C2000027RemoteA | read-write | current | EDD Series card Port 2 L2CP Mode 0180C2000027 0: Forward 1: Peer |
| 1.3.6.1.4.1.4756.20.441.20.1.903 | ColumneddL2CPPort2DMAC0180C2000028RemoteA | read-write | current | EDD Series card Port 2 L2CP Mode 0180C2000028 0: Forward 1: Peer |
| 1.3.6.1.4.1.4756.20.441.20.1.904 | ColumneddL2CPPort2DMAC0180C2000029RemoteA | read-write | current | EDD Series card Port 2 L2CP Mode 0180C2000029 0: Forward 1: Peer |
| 1.3.6.1.4.1.4756.20.441.20.1.905 | ColumneddL2CPPort2DMAC0180C200002ARemoteA | read-write | current | EDD Series card Port 2 L2CP Mode 0180C200002A 0: Forward 1: Peer |
| 1.3.6.1.4.1.4756.20.441.20.1.906 | ColumneddL2CPPort2DMAC0180C200002BRemoteA | read-write | current | EDD Series card Port 2 L2CP Mode 0180C200002B 0: Forward 1: Peer |
| 1.3.6.1.4.1.4756.20.441.20.1.907 | ColumneddL2CPPort2DMAC0180C200002CRemoteA | read-write | current | EDD Series card Port 2 L2CP Mode 0180C200002C 0: Forward 1: Peer |
| 1.3.6.1.4.1.4756.20.441.20.1.908 | ColumneddL2CPPort2DMAC0180C200002DRemoteA | read-write | current | EDD Series card Port 2 L2CP Mode 0180C200002D 0: Forward 1: Peer |
| 1.3.6.1.4.1.4756.20.441.20.1.909 | ColumneddL2CPPort2DMAC0180C200002ERemoteA | read-write | current | EDD Series card Port 2 L2CP Mode 0180C200002E 0: Forward 1: Peer |
| 1.3.6.1.4.1.4756.20.441.20.1.910 | ColumneddL2CPPort2DMAC0180C200002FRemoteA | read-write | current | EDD Series card Port 2 L2CP Mode 0180C200002F 0: Forward 1: Peer |
| 1.3.6.1.4.1.4756.20.441.20.1.911 | ColumneddL2CPPort3DMAC0180C2000000RemoteA | read-write | current | EDD Series card Port 3 L2CP Mode 0180C2000000 0: Forward 1: Peer |
| 1.3.6.1.4.1.4756.20.441.20.1.912 | ColumneddL2CPPort3DMAC0180C2000001RemoteA | read-write | current | EDD Series card Port 3 L2CP Mode 0180C2000001 0: Forward 1: Peer |
| 1.3.6.1.4.1.4756.20.441.20.1.913 | ColumneddL2CPPort3DMAC0180C2000002RemoteA | read-write | current | EDD Series card Port 3 L2CP Mode 0180C2000002 0: Forward 1: Peer |
| 1.3.6.1.4.1.4756.20.441.20.1.914 | ColumneddL2CPPort3DMAC0180C2000003RemoteA | read-write | current | EDD Series card Port 3 L2CP Mode 0180C2000003 0: Forward 1: Peer |
| 1.3.6.1.4.1.4756.20.441.20.1.915 | ColumneddL2CPPort3DMAC0180C2000004RemoteA | read-write | current | EDD Series card Port 3 L2CP Mode 0180C2000004 0: Forward 1: Peer |
| 1.3.6.1.4.1.4756.20.441.20.1.916 | ColumneddL2CPPort3DMAC0180C2000005RemoteA | read-write | current | EDD Series card Port 3 L2CP Mode 0180C2000005 0: Forward 1: Peer |
| 1.3.6.1.4.1.4756.20.441.20.1.917 | ColumneddL2CPPort3DMAC0180C2000006RemoteA | read-write | current | EDD Series card Port 3 L2CP Mode 0180C2000006 0: Forward 1: Peer |
| 1.3.6.1.4.1.4756.20.441.20.1.918 | ColumneddL2CPPort3DMAC0180C2000007RemoteA | read-write | current | EDD Series card Port 3 L2CP Mode 0180C2000007 0: Forward 1: Peer |
| 1.3.6.1.4.1.4756.20.441.20.1.919 | ColumneddL2CPPort3DMAC0180C2000008RemoteA | read-write | current | EDD Series card Port 3 L2CP Mode 0180C2000008 0: Forward 1: Peer |
| 1.3.6.1.4.1.4756.20.441.20.1.920 | ColumneddL2CPPort3DMAC0180C2000009RemoteA | read-write | current | EDD Series card Port 3 L2CP Mode 0180C2000009 0: Forward 1: Peer |
| 1.3.6.1.4.1.4756.20.441.20.1.921 | ColumneddL2CPPort3DMAC0180C200000ARemoteA | read-write | current | EDD Series card Port 3 L2CP Mode 0180C200000A 0: Forward 1: Peer |
| 1.3.6.1.4.1.4756.20.441.20.1.922 | ColumneddL2CPPort3DMAC0180C200000BRemoteA | read-write | current | EDD Series card Port 3 L2CP Mode 0180C200000B 0: Forward 1: Peer |
| 1.3.6.1.4.1.4756.20.441.20.1.923 | ColumneddL2CPPort3DMAC0180C200000CRemoteA | read-write | current | EDD Series card Port 3 L2CP Mode 0180C200000C 0: Forward 1: Peer |
| 1.3.6.1.4.1.4756.20.441.20.1.924 | ColumneddL2CPPort3DMAC0180C200000DRemoteA | read-write | current | EDD Series card Port 3 L2CP Mode 0180C200000D 0: Forward 1: Peer |
| 1.3.6.1.4.1.4756.20.441.20.1.925 | ColumneddL2CPPort3DMAC0180C200000ERemoteA | read-write | current | EDD Series card Port 3 L2CP Mode 0180C200000E 0: Forward 1: Peer |
| 1.3.6.1.4.1.4756.20.441.20.1.926 | ColumneddL2CPPort3DMAC0180C200000FRemoteA | read-write | current | EDD Series card Port 3 L2CP Mode 0180C200000F 0: Forward 1: Peer |
| 1.3.6.1.4.1.4756.20.441.20.1.927 | ColumneddL2CPPort3DMAC0180C2000010RemoteA | read-write | current | EDD Series card Port 3 L2CP Mode 0180C2000010 0: Forward 1: Peer |
| 1.3.6.1.4.1.4756.20.441.20.1.928 | ColumneddL2CPPort3DMAC0180C2000020RemoteA | read-write | current | EDD Series card Port 3 L2CP Mode 0180C2000020 0: Forward 1: Peer |
| 1.3.6.1.4.1.4756.20.441.20.1.929 | ColumneddL2CPPort3DMAC0180C2000021RemoteA | read-write | current | EDD Series card Port 3 L2CP Mode 0180C2000021 0: Forward 1: Peer |
| 1.3.6.1.4.1.4756.20.441.20.1.930 | ColumneddL2CPPort3DMAC0180C2000022RemoteA | read-write | current | EDD Series card Port 3 L2CP Mode 0180C2000022 0: Forward 1: Peer |
| 1.3.6.1.4.1.4756.20.441.20.1.931 | ColumneddL2CPPort3DMAC0180C2000023RemoteA | read-write | current | EDD Series card Port 3 L2CP Mode 0180C2000023 0: Forward 1: Peer |
| 1.3.6.1.4.1.4756.20.441.20.1.932 | ColumneddL2CPPort3DMAC0180C2000024RemoteA | read-write | current | EDD Series card Port 3 L2CP Mode 0180C2000024 0: Forward 1: Peer |
| 1.3.6.1.4.1.4756.20.441.20.1.933 | ColumneddL2CPPort3DMAC0180C2000025RemoteA | read-write | current | EDD Series card Port 3 L2CP Mode 0180C2000025 0: Forward 1: Peer |
| 1.3.6.1.4.1.4756.20.441.20.1.934 | ColumneddL2CPPort3DMAC0180C2000026RemoteA | read-write | current | EDD Series card Port 3 L2CP Mode 0180C2000026 0: Forward 1: Peer |
| 1.3.6.1.4.1.4756.20.441.20.1.935 | ColumneddL2CPPort3DMAC0180C2000027RemoteA | read-write | current | EDD Series card Port 3 L2CP Mode 0180C2000027 0: Forward 1: Peer |
| 1.3.6.1.4.1.4756.20.441.20.1.936 | ColumneddL2CPPort3DMAC0180C2000028RemoteA | read-write | current | EDD Series card Port 3 L2CP Mode 0180C2000028 0: Forward 1: Peer |
| 1.3.6.1.4.1.4756.20.441.20.1.937 | ColumneddL2CPPort3DMAC0180C2000029RemoteA | read-write | current | EDD Series card Port 3 L2CP Mode 0180C2000029 0: Forward 1: Peer |
| 1.3.6.1.4.1.4756.20.441.20.1.938 | ColumneddL2CPPort3DMAC0180C200002ARemoteA | read-write | current | EDD Series card Port 3 L2CP Mode 0180C200002A 0: Forward 1: Peer |
| 1.3.6.1.4.1.4756.20.441.20.1.939 | ColumneddL2CPPort3DMAC0180C200002BRemoteA | read-write | current | EDD Series card Port 3 L2CP Mode 0180C200002B 0: Forward 1: Peer |
| 1.3.6.1.4.1.4756.20.441.20.1.940 | ColumneddL2CPPort3DMAC0180C200002CRemoteA | read-write | current | EDD Series card Port 3 L2CP Mode 0180C200002C 0: Forward 1: Peer |
| 1.3.6.1.4.1.4756.20.441.20.1.941 | ColumneddL2CPPort3DMAC0180C200002DRemoteA | read-write | current | EDD Series card Port 3 L2CP Mode 0180C200002D 0: Forward 1: Peer |
| 1.3.6.1.4.1.4756.20.441.20.1.942 | ColumneddL2CPPort3DMAC0180C200002ERemoteA | read-write | current | EDD Series card Port 3 L2CP Mode 0180C200002E 0: Forward 1: Peer |
| 1.3.6.1.4.1.4756.20.441.20.1.943 | ColumneddL2CPPort3DMAC0180C200002FRemoteA | read-write | current | EDD Series card Port 3 L2CP Mode 0180C200002F 0: Forward 1: Peer |
| 1.3.6.1.4.1.4756.20.441.20.1.944 | ColumneddL2CPPort4DMAC0180C2000000RemoteA | read-write | current | EDD Series card Port 4 L2CP Mode 0180C2000000 0: Forward 1: Peer |
| 1.3.6.1.4.1.4756.20.441.20.1.945 | ColumneddL2CPPort4DMAC0180C2000001RemoteA | read-write | current | EDD Series card Port 4 L2CP Mode 0180C2000001 0: Forward 1: Peer |
| 1.3.6.1.4.1.4756.20.441.20.1.946 | ColumneddL2CPPort4DMAC0180C2000002RemoteA | read-write | current | EDD Series card Port 4 L2CP Mode 0180C2000002 0: Forward 1: Peer |
| 1.3.6.1.4.1.4756.20.441.20.1.947 | ColumneddL2CPPort4DMAC0180C2000003RemoteA | read-write | current | EDD Series card Port 4 L2CP Mode 0180C2000003 0: Forward 1: Peer |
| 1.3.6.1.4.1.4756.20.441.20.1.948 | ColumneddL2CPPort4DMAC0180C2000004RemoteA | read-write | current | EDD Series card Port 4 L2CP Mode 0180C2000004 0: Forward 1: Peer |
| 1.3.6.1.4.1.4756.20.441.20.1.949 | ColumneddL2CPPort4DMAC0180C2000005RemoteA | read-write | current | EDD Series card Port 4 L2CP Mode 0180C2000005 0: Forward 1: Peer |
| 1.3.6.1.4.1.4756.20.441.20.1.950 | ColumneddL2CPPort4DMAC0180C2000006RemoteA | read-write | current | EDD Series card Port 4 L2CP Mode 0180C2000006 0: Forward 1: Peer |
| 1.3.6.1.4.1.4756.20.441.20.1.951 | ColumneddL2CPPort4DMAC0180C2000007RemoteA | read-write | current | EDD Series card Port 4 L2CP Mode 0180C2000007 0: Forward 1: Peer |
| 1.3.6.1.4.1.4756.20.441.20.1.952 | ColumneddL2CPPort4DMAC0180C2000008RemoteA | read-write | current | EDD Series card Port 4 L2CP Mode 0180C2000008 0: Forward 1: Peer |
| 1.3.6.1.4.1.4756.20.441.20.1.953 | ColumneddL2CPPort4DMAC0180C2000009RemoteA | read-write | current | EDD Series card Port 4 L2CP Mode 0180C2000009 0: Forward 1: Peer |
| 1.3.6.1.4.1.4756.20.441.20.1.954 | ColumneddL2CPPort4DMAC0180C200000ARemoteA | read-write | current | EDD Series card Port 4 L2CP Mode 0180C200000A 0: Forward 1: Peer |
| 1.3.6.1.4.1.4756.20.441.20.1.955 | ColumneddL2CPPort4DMAC0180C200000BRemoteA | read-write | current | EDD Series card Port 4 L2CP Mode 0180C200000B 0: Forward 1: Peer |
| 1.3.6.1.4.1.4756.20.441.20.1.956 | ColumneddL2CPPort4DMAC0180C200000CRemoteA | read-write | current | EDD Series card Port 4 L2CP Mode 0180C200000C 0: Forward 1: Peer |
| 1.3.6.1.4.1.4756.20.441.20.1.957 | ColumneddL2CPPort4DMAC0180C200000DRemoteA | read-write | current | EDD Series card Port 4 L2CP Mode 0180C200000D 0: Forward 1: Peer |
| 1.3.6.1.4.1.4756.20.441.20.1.958 | ColumneddL2CPPort4DMAC0180C200000ERemoteA | read-write | current | EDD Series card Port 4 L2CP Mode 0180C200000E 0: Forward 1: Peer |
| 1.3.6.1.4.1.4756.20.441.20.1.959 | ColumneddL2CPPort4DMAC0180C200000FRemoteA | read-write | current | EDD Series card Port 4 L2CP Mode 0180C200000F 0: Forward 1: Peer |
| 1.3.6.1.4.1.4756.20.441.20.1.960 | ColumneddL2CPPort4DMAC0180C2000010RemoteA | read-write | current | EDD Series card Port 4 L2CP Mode 0180C2000010 0: Forward 1: Peer |
| 1.3.6.1.4.1.4756.20.441.20.1.961 | ColumneddL2CPPort4DMAC0180C2000020RemoteA | read-write | current | EDD Series card Port 4 L2CP Mode 0180C2000020 0: Forward 1: Peer |
| 1.3.6.1.4.1.4756.20.441.20.1.962 | ColumneddL2CPPort4DMAC0180C2000021RemoteA | read-write | current | EDD Series card Port 4 L2CP Mode 0180C2000021 0: Forward 1: Peer |
| 1.3.6.1.4.1.4756.20.441.20.1.963 | ColumneddL2CPPort4DMAC0180C2000022RemoteA | read-write | current | EDD Series card Port 4 L2CP Mode 0180C2000022 0: Forward 1: Peer |
| 1.3.6.1.4.1.4756.20.441.20.1.964 | ColumneddL2CPPort4DMAC0180C2000023RemoteA | read-write | current | EDD Series card Port 4 L2CP Mode 0180C2000023 0: Forward 1: Peer |
| 1.3.6.1.4.1.4756.20.441.20.1.965 | ColumneddL2CPPort4DMAC0180C2000024RemoteA | read-write | current | EDD Series card Port 4 L2CP Mode 0180C2000024 0: Forward 1: Peer |
| 1.3.6.1.4.1.4756.20.441.20.1.966 | ColumneddL2CPPort4DMAC0180C2000025RemoteA | read-write | current | EDD Series card Port 4 L2CP Mode 0180C2000025 0: Forward 1: Peer |
| 1.3.6.1.4.1.4756.20.441.20.1.967 | ColumneddL2CPPort4DMAC0180C2000026RemoteA | read-write | current | EDD Series card Port 4 L2CP Mode 0180C2000026 0: Forward 1: Peer |
| 1.3.6.1.4.1.4756.20.441.20.1.968 | ColumneddL2CPPort4DMAC0180C2000027RemoteA | read-write | current | EDD Series card Port 4 L2CP Mode 0180C2000027 0: Forward 1: Peer |
| 1.3.6.1.4.1.4756.20.441.20.1.969 | ColumneddL2CPPort4DMAC0180C2000028RemoteA | read-write | current | EDD Series card Port 4 L2CP Mode 0180C2000028 0: Forward 1: Peer |
| 1.3.6.1.4.1.4756.20.441.20.1.970 | ColumneddL2CPPort4DMAC0180C2000029RemoteA | read-write | current | EDD Series card Port 4 L2CP Mode 0180C2000029 0: Forward 1: Peer |
| 1.3.6.1.4.1.4756.20.441.20.1.971 | ColumneddL2CPPort4DMAC0180C200002ARemoteA | read-write | current | EDD Series card Port 4 L2CP Mode 0180C200002A 0: Forward 1: Peer |
| 1.3.6.1.4.1.4756.20.441.20.1.972 | ColumneddL2CPPort4DMAC0180C200002BRemoteA | read-write | current | EDD Series card Port 4 L2CP Mode 0180C200002B 0: Forward 1: Peer |
| 1.3.6.1.4.1.4756.20.441.20.1.973 | ColumneddL2CPPort4DMAC0180C200002CRemoteA | read-write | current | EDD Series card Port 4 L2CP Mode 0180C200002C 0: Forward 1: Peer |
| 1.3.6.1.4.1.4756.20.441.20.1.974 | ColumneddL2CPPort4DMAC0180C200002DRemoteA | read-write | current | EDD Series card Port 4 L2CP Mode 0180C200002D 0: Forward 1: Peer |
| 1.3.6.1.4.1.4756.20.441.20.1.975 | ColumneddL2CPPort4DMAC0180C200002ERemoteA | read-write | current | EDD Series card Port 4 L2CP Mode 0180C200002E 0: Forward 1: Peer |
| 1.3.6.1.4.1.4756.20.441.20.1.976 | ColumneddL2CPPort4DMAC0180C200002FRemoteA | read-write | current | EDD Series card Port 4 L2CP Mode 0180C200002F 0: Forward 1: Peer |
| 1.3.6.1.4.1.4756.20.441.20.1.977 | ColumneddPort1MEPInstanceRemoteA | read-write | current | EDD Series card Port 1 MEP Instance 'MEP ID' must be an integer value between 0 and 8191. |
| 1.3.6.1.4.1.4756.20.441.20.1.978 | ColumneddPort1MEPLogicRemoteA | read-write | current | EDD Series card Port 1 MEP Logic 0: And 1: OR |
| 1.3.6.1.4.1.4756.20.441.20.1.979 | ColumneddPort2MEPInstanceRemoteA | read-write | current | EDD Series card Port 2 MEP Instance 'MEP ID' must be an integer value between 0 and 8191. |
| 1.3.6.1.4.1.4756.20.441.20.1.980 | ColumneddPort2MEPLogicRemoteA | read-write | current | EDD Series card Port 2 MEP Logic 0: And 1: OR |
| 1.3.6.1.4.1.4756.20.441.20.1.981 | ColumneddPort3MEPInstanceRemoteA | read-write | current | EDD Series card Port 3 MEP Instance 'MEP ID' must be an integer value between 0 and 8191. |
| 1.3.6.1.4.1.4756.20.441.20.1.982 | ColumneddPort3MEPLogicRemoteA | read-write | current | EDD Series card Port 3 MEP Logic 0: And 1: OR |
| 1.3.6.1.4.1.4756.20.441.20.1.983 | ColumneddPort4MEPInstanceRemoteA | read-write | current | EDD Series card Port 4 MEP Instance 'MEP ID' must be an integer value between 0 and 8191. |
| 1.3.6.1.4.1.4756.20.441.20.1.984 | ColumneddPort4MEPLogicRemoteA | read-write | current | EDD Series card Port 4 MEP Logic 0: And 1: OR |
| 1.3.6.1.4.1.4756.20.442 | NodeeddRemoteBCards | |||
| 1.3.6.1.4.1.4756.20.442.20 | TableeddRemoteBTable | not-accessible | current | A list of RemoteB FRM220-EDD series card entries. |
| 1.3.6.1.4.1.4756.20.442.20.1 | RoweddRemoteBEntry | not-accessible | current | An entry containing management information applicable to a particular FRM220-EDD series card. |
| 1.3.6.1.4.1.4756.20.442.20.1.1 | ColumneddChassisIndexRemoteB | read-only | current | A unique value for each card. It starts from 0 to 9 contiguously. |
| 1.3.6.1.4.1.4756.20.442.20.1.2 | ColumneddSlotIndexRemoteB | read-only | current | A unique value for each card. It starts from 1 to 20 contiguously. |
| 1.3.6.1.4.1.4756.20.442.20.1.3 | ColumneddCardHWVerRemoteB | read-only | current | EDD Series card hardware version x.xxx |
| 1.3.6.1.4.1.4756.20.442.20.1.4 | ColumneddCardFWVerRemoteB | read-only | current | EDD Series card firmware version x.xxx |
| 1.3.6.1.4.1.4756.20.442.20.1.5 | ColumneddCardCPLDVerRemoteB | read-only | current | EDD Series card CPLD version x.xxx |
| 1.3.6.1.4.1.4756.20.442.20.1.6 | ColumneddCardFPGAVerRemoteB | read-only | current | EDD Series card FPGA version x.xxx |
| 1.3.6.1.4.1.4756.20.442.20.1.7 | ColumneddModelRemoteB | read-only | current | Card Type: 0:MX210 1:MSW202 |
| 1.3.6.1.4.1.4756.20.442.20.1.8 | ColumneddPort1LinkstsRemoteB | read-only | current | EDD Series card Port1 link status: 0:Link down 1:Link up |
| 1.3.6.1.4.1.4756.20.442.20.1.9 | ColumneddPort1SpeedstsRemoteB | read-only | current | EDD Series card Port1 speed status 10Base-T 100Base-Tx 1000Base-Tx 2.5G |
| 1.3.6.1.4.1.4756.20.442.20.1.10 | ColumneddPort1DuplexstsRemoteB | read-only | current | EDD Series card Port1 duplex status 0: Half 1: Full |
| 1.3.6.1.4.1.4756.20.442.20.1.11 | ColumneddPort1RxPausestsRemoteB | read-only | current | EDD Series card Port1 rx pause status 0: No 1: Yes |
| 1.3.6.1.4.1.4756.20.442.20.1.12 | ColumneddPort1TxPausestsRemoteB | read-only | current | EDD Series card Port1 tx pause status 0: No 1: Yes |
| 1.3.6.1.4.1.4756.20.442.20.1.13 | ColumneddPort2LinkstsRemoteB | read-only | current | EDD Series card Port2 link status: 0:Link down 1:Link up |
| 1.3.6.1.4.1.4756.20.442.20.1.14 | ColumneddPort2SpeedstsRemoteB | read-only | current | EDD Series card Port2 speed status 10Base-T 100Base-Tx 1000Base-Tx 2.5G |
| 1.3.6.1.4.1.4756.20.442.20.1.15 | ColumneddPort2DuplexstsRemoteB | read-only | current | EDD Series card Port2 duplex status 0: Half 1: Full |
| 1.3.6.1.4.1.4756.20.442.20.1.16 | ColumneddPort2RxPausestsRemoteB | read-only | current | EDD Series card Port2 rx pause status 0: No 1: Yes |
| 1.3.6.1.4.1.4756.20.442.20.1.17 | ColumneddPort2TxPausestsRemoteB | read-only | current | EDD Series card Port2 tx pause status 0: No 1: Yes |
| 1.3.6.1.4.1.4756.20.442.20.1.18 | ColumneddPort3LinkstsRemoteB | read-only | current | EDD Series card Port3 link status: 0:Link down 1:Link up |
| 1.3.6.1.4.1.4756.20.442.20.1.19 | ColumneddPort3SpeedstsRemoteB | read-only | current | EDD Series card Port3 speed status 10Base-T 100Base-Tx 1000Base-Tx |
| 1.3.6.1.4.1.4756.20.442.20.1.20 | ColumneddPort3DuplexstsRemoteB | read-only | current | EDD Series card Port3 duplex status 0: Half 1: Full |
| 1.3.6.1.4.1.4756.20.442.20.1.21 | ColumneddPort3RxPausestsRemoteB | read-only | current | EDD Series card Port3 rx pause status 0: No 1: Yes |
| 1.3.6.1.4.1.4756.20.442.20.1.22 | ColumneddPort3TxPausestsRemoteB | read-only | current | EDD Series card Port3 tx pause status 0: No 1: Yes |
| 1.3.6.1.4.1.4756.20.442.20.1.23 | ColumneddPort4LinkstsRemoteB | read-only | current | EDD Series card Port4 link status: 0:Link down 1:Link up |
| 1.3.6.1.4.1.4756.20.442.20.1.24 | ColumneddPort4SpeedstsRemoteB | read-only | current | EDD Series card Port4 speed status 10Base-T 100Base-Tx 1000Base-Tx |
| 1.3.6.1.4.1.4756.20.442.20.1.25 | ColumneddPort4DuplexstsRemoteB | read-only | current | EDD Series card Port4 duplex status 0: Half 1: Full |
| 1.3.6.1.4.1.4756.20.442.20.1.26 | ColumneddPort4RxPausestsRemoteB | read-only | current | EDD Series card Port4 rx pause status 0: No 1: Yes |
| 1.3.6.1.4.1.4756.20.442.20.1.27 | ColumneddPort4TxPausestsRemoteB | read-only | current | EDD Series card Port4 tx pause status 0: No 1: Yes |
| 1.3.6.1.4.1.4756.20.442.20.1.28 | ColumneddPort1SpeedConfRemoteB | read-write | current | EDD Series card Port1 speed config 0: disable 1: auto 2: 100M FDX 3: 1G FDX 4: 2.5G FDX |
| 1.3.6.1.4.1.4756.20.442.20.1.29 | ColumneddPort1flowConrolRemoteB | read-write | current | EDD Series card Port1 flow control config 0: no 1: yes |
| 1.3.6.1.4.1.4756.20.442.20.1.30 | ColumneddPort1MaxFrameRemoteB | read-write | current | EDD Series card Port1 max frame config |
| 1.3.6.1.4.1.4756.20.442.20.1.31 | ColumneddPort2SpeedConfRemoteB | read-write | current | EDD Series card Port2 speed config 0: disable 1: auto 2: 100M FDX 3: 1G FDX 4: 2.5G FDX |
| 1.3.6.1.4.1.4756.20.442.20.1.32 | ColumneddPort2flowConrolRemoteB | read-write | current | EDD Series card Port2 flow control config 0: no 1: yes |
| 1.3.6.1.4.1.4756.20.442.20.1.33 | ColumneddPort2MaxFrameRemoteB | read-write | current | EDD Series card Port2 max frame config |
| 1.3.6.1.4.1.4756.20.442.20.1.34 | ColumneddPort3SpeedConfRemoteB | read-write | current | EDD Series card Port3 speed config 0: disable 1: auto 2: 10M HDX 3: 10M FDX 4: 100M HDX 5: 100M FDX 6: 1G FDX |
| 1.3.6.1.4.1.4756.20.442.20.1.35 | ColumneddPort3flowConrolRemoteB | read-write | current | EDD Series card Port3 flow control config 0: no 1: yes |
| 1.3.6.1.4.1.4756.20.442.20.1.36 | ColumneddPort3MaxFrameRemoteB | read-write | current | EDD Series card Port3 max frame config |
| 1.3.6.1.4.1.4756.20.442.20.1.37 | ColumneddPort3CollisionModeRemoteB | read-write | current | EDD Series card Port3 collision mode config.(MSW202 only) 0: Discard 1: Restart |
| 1.3.6.1.4.1.4756.20.442.20.1.38 | ColumneddPort4SpeedConfRemoteB | read-write | current | EDD Series card Port4 speed config 0: disable 1: auto 2: 10M HDX 3: 10M FDX 4: 100M HDX 5: 100M FDX 6: 1G FDX |
| 1.3.6.1.4.1.4756.20.442.20.1.39 | ColumneddPort4flowConrolRemoteB | read-write | current | EDD Series card Port4 flow control config 0: no 1: yes |
| 1.3.6.1.4.1.4756.20.442.20.1.40 | ColumneddPort4MaxFrameRemoteB | read-write | current | EDD Series card Port4 max frame config |
| 1.3.6.1.4.1.4756.20.442.20.1.41 | ColumneddPort4CollisionModeRemoteB | read-write | current | EDD Series card Port4 collision mode config 0: Discard 1: Restart |
| 1.3.6.1.4.1.4756.20.442.20.1.42 | ColumneddSaveStartupCongRemoteB | read-write | current | EDD Series card save start-up config 0: OFF 1: Action |
| 1.3.6.1.4.1.4756.20.442.20.1.43 | ColumneddPortResetRemoteB | read-write | current | EDD Series card port reset 0: OFF 1: Action |
| 1.3.6.1.4.1.4756.20.442.20.1.44 | ColumneddSetDefaultRemoteB | read-write | current | EDD Series card set to default config 0: OFF 1: Action |
| 1.3.6.1.4.1.4756.20.442.20.1.45 | ColumneddMuxModeRemoteB | read-write | current | EDD Series card Mux mode (MX210 only) 0: Disable 1: Switch 2: Isolate 3: VLAN |
| 1.3.6.1.4.1.4756.20.442.20.1.46 | ColumneddPort1PacketsRxRemoteB | read-only | current | EDD Series card port1 traffic overview:: Packets Rx |
| 1.3.6.1.4.1.4756.20.442.20.1.47 | ColumneddPort1PacketsTxRemoteB | read-only | current | EDD Series card port1 traffic overview:: Packets Tx |
| 1.3.6.1.4.1.4756.20.442.20.1.48 | ColumneddPort1BytesRxRemoteB | read-only | current | EDD Series card port1 traffic overview:: Bytes Rx |
| 1.3.6.1.4.1.4756.20.442.20.1.49 | ColumneddPort1BytesTxRemoteB | read-only | current | EDD Series card port1 traffic overview:: Bytes Tx |
| 1.3.6.1.4.1.4756.20.442.20.1.50 | ColumneddPort1ErrorsRxRemoteB | read-only | current | EDD Series card port1 traffic overview:: Errors Rx |
| 1.3.6.1.4.1.4756.20.442.20.1.51 | ColumneddPort1ErrorsTxRemoteB | read-only | current | EDD Series card port1 traffic overview:: Errors Tx |
| 1.3.6.1.4.1.4756.20.442.20.1.52 | ColumneddPort1DropsRxRemoteB | read-only | current | EDD Series card port1 traffic overview:: Drops Rx |
| 1.3.6.1.4.1.4756.20.442.20.1.53 | ColumneddPort1DropsTxRemoteB | read-only | current | EDD Series card port1 traffic overview:: Drops Tx |
| 1.3.6.1.4.1.4756.20.442.20.1.54 | ColumneddPort1FilteredRxRemoteB | read-only | current | EDD Series card port1 traffic overview:: Filtered Rx |
| 1.3.6.1.4.1.4756.20.442.20.1.55 | ColumneddPort2PacketsRxRemoteB | read-only | current | EDD Series card port2 traffic overview:: Packets Rx |
| 1.3.6.1.4.1.4756.20.442.20.1.56 | ColumneddPort2PacketsTxRemoteB | read-only | current | EDD Series card port2 traffic overview:: Packets Tx |
| 1.3.6.1.4.1.4756.20.442.20.1.57 | ColumneddPort2BytesRxRemoteB | read-only | current | EDD Series card port2 traffic overview:: Bytes Rx |
| 1.3.6.1.4.1.4756.20.442.20.1.58 | ColumneddPort2BytesTxRemoteB | read-only | current | EDD Series card port2 traffic overview:: Bytes Tx |
| 1.3.6.1.4.1.4756.20.442.20.1.59 | ColumneddPort2ErrorsRxRemoteB | read-only | current | EDD Series card port2 traffic overview:: Errors Rx |
| 1.3.6.1.4.1.4756.20.442.20.1.60 | ColumneddPort2ErrorsTxRemoteB | read-only | current | EDD Series card port2 traffic overview:: Errors Tx |
| 1.3.6.1.4.1.4756.20.442.20.1.61 | ColumneddPort2DropsRxRemoteB | read-only | current | EDD Series card port2 traffic overview:: Drops Rx |
| 1.3.6.1.4.1.4756.20.442.20.1.62 | ColumneddPort2DropsTxRemoteB | read-only | current | EDD Series card port2 traffic overview:: Drops Tx |
| 1.3.6.1.4.1.4756.20.442.20.1.63 | ColumneddPort2FilteredRxRemoteB | read-only | current | EDD Series card port2 traffic overview:: Filtered Rx |
| 1.3.6.1.4.1.4756.20.442.20.1.64 | ColumneddPort3PacketsRxRemoteB | read-only | current | EDD Series card port3 traffic overview:: Packets Rx |
| 1.3.6.1.4.1.4756.20.442.20.1.65 | ColumneddPort3PacketsTxRemoteB | read-only | current | EDD Series card port3 traffic overview:: Packets Tx |
| 1.3.6.1.4.1.4756.20.442.20.1.66 | ColumneddPort3BytesRxRemoteB | read-only | current | EDD Series card port3 traffic overview:: Bytes Rx |
| 1.3.6.1.4.1.4756.20.442.20.1.67 | ColumneddPort3BytesTxRemoteB | read-only | current | EDD Series card port3 traffic overview:: Bytes Tx |
| 1.3.6.1.4.1.4756.20.442.20.1.68 | ColumneddPort3ErrorsRxRemoteB | read-only | current | EDD Series card port3 traffic overview:: Errors Rx |
| 1.3.6.1.4.1.4756.20.442.20.1.69 | ColumneddPort3ErrorsTxRemoteB | read-only | current | EDD Series card port3 traffic overview:: Errors Tx |
| 1.3.6.1.4.1.4756.20.442.20.1.70 | ColumneddPort3DropsRxRemoteB | read-only | current | EDD Series card port3 traffic overview:: Drops Rx |
| 1.3.6.1.4.1.4756.20.442.20.1.71 | ColumneddPort3DropsTxRemoteB | read-only | current | EDD Series card port3 traffic overview:: Drops Tx |
| 1.3.6.1.4.1.4756.20.442.20.1.72 | ColumneddPort3FilteredRxRemoteB | read-only | current | EDD Series card port3 traffic overview:: Filtered Rx |
| 1.3.6.1.4.1.4756.20.442.20.1.73 | ColumneddPort4PacketsRxRemoteB | read-only | current | EDD Series card port4 traffic overview:: Packets Rx |
| 1.3.6.1.4.1.4756.20.442.20.1.74 | ColumneddPort4PacketsTxRemoteB | read-only | current | EDD Series card port4 traffic overview:: Packets Tx |
| 1.3.6.1.4.1.4756.20.442.20.1.75 | ColumneddPort4BytesRxRemoteB | read-only | current | EDD Series card port4 traffic overview:: Bytes Rx |
| 1.3.6.1.4.1.4756.20.442.20.1.76 | ColumneddPort4BytesTxRemoteB | read-only | current | EDD Series card port4 traffic overview:: Bytes Tx |
| 1.3.6.1.4.1.4756.20.442.20.1.77 | ColumneddPort4ErrorsRxRemoteB | read-only | current | EDD Series card port4 traffic overview:: Errors Rx |
| 1.3.6.1.4.1.4756.20.442.20.1.78 | ColumneddPort4ErrorsTxRemoteB | read-only | current | EDD Series card port4 traffic overview:: Errors Tx |
| 1.3.6.1.4.1.4756.20.442.20.1.79 | ColumneddPort4DropsRxRemoteB | read-only | current | EDD Series card port4 traffic overview:: Drops Rx |
| 1.3.6.1.4.1.4756.20.442.20.1.80 | ColumneddPort4DropsTxRemoteB | read-only | current | EDD Series card port4 traffic overview:: Drops Tx |
| 1.3.6.1.4.1.4756.20.442.20.1.81 | ColumneddPort4FilteredRxRemoteB | read-only | current | EDD Series card port4 traffic overview:: Filtered Rx |
| 1.3.6.1.4.1.4756.20.442.20.1.82 | ColumnedduRingInstanceAddRemoteB | read-write | current | EDD Series card Add a new uRing Instance. Syntax: <Instance ID> <ring|sub|chain> <port east> <port west> Instance ID must be either 1 or 2 port east , the valu… |
| 1.3.6.1.4.1.4756.20.442.20.1.83 | ColumnedduRingInstanceDeleteRemoteB | read-write | current | EDD Series card Delete a uRing Instance. Syntax: <uRing Instance> |
| 1.3.6.1.4.1.4756.20.442.20.1.84 | ColumnedduRingInst1IDRemoteB | read-only | current | EDD Series card u-Ring instance1 ID |
| 1.3.6.1.4.1.4756.20.442.20.1.85 | ColumnedduRingInst1typeRemoteB | read-only | current | EDD Series card u-Ring instance1 type 0: u-Ring 1: Sub-Ring 2: u-Chain |
| 1.3.6.1.4.1.4756.20.442.20.1.86 | ColumnedduRingInst1masterRemoteB | read-write | current | EDD Series card u-Ring instance1 master 0: No 1: Yes |
| 1.3.6.1.4.1.4756.20.442.20.1.87 | ColumnedduRingInst1EastPortRemoteB | read-only | current | EDD Series card u-Ring instance1 east port |
| 1.3.6.1.4.1.4756.20.442.20.1.88 | ColumnedduRingInst1EastEdgeRemoteB | read-write | current | EDD Series card u-Ring instance1 east edge 0: No 1: Yes |
| 1.3.6.1.4.1.4756.20.442.20.1.89 | ColumnedduRingInst1WestPortRemoteB | read-only | current | EDD Series card u-Ring instance1 west port |
| 1.3.6.1.4.1.4756.20.442.20.1.90 | ColumnedduRingInst1WestEdgeRemoteB | read-write | current | EDD Series card u-Ring instance1 west edge 0: No 1: Yes |
| 1.3.6.1.4.1.4756.20.442.20.1.91 | ColumnedduRingInst2IDRemoteB | read-only | current | EDD Series card u-Ring instance2 ID |
| 1.3.6.1.4.1.4756.20.442.20.1.92 | ColumnedduRingInst2typeRemoteB | read-only | current | EDD Series card u-Ring instance2 type 0: u-Ring 1: Sub-Ring 2: u-Chain |
| 1.3.6.1.4.1.4756.20.442.20.1.93 | ColumnedduRingInst2masterRemoteB | read-write | current | EDD Series card u-Ring instance2 master 0: No 1: Yes |
| 1.3.6.1.4.1.4756.20.442.20.1.94 | ColumnedduRingInst2EastPortRemoteB | read-only | current | EDD Series card u-Ring instance2 east port |
| 1.3.6.1.4.1.4756.20.442.20.1.95 | ColumnedduRingInst2EastEdgeRemoteB | read-write | current | EDD Series card u-Ring instance2 east edge 0: No 1: Yes |
| 1.3.6.1.4.1.4756.20.442.20.1.96 | ColumnedduRingInst2WestPortRemoteB | read-only | current | EDD Series card u-Ring instance2 west port |
| 1.3.6.1.4.1.4756.20.442.20.1.97 | ColumnedduRingInst2WestEdgeRemoteB | read-write | current | EDD Series card u-Ring instance2 west edge 0: No 1: Yes |
| 1.3.6.1.4.1.4756.20.442.20.1.98 | ColumnedduRingInst1IDstsRemoteB | read-only | current | EDD Series card u-Ring Instance1 ID status |
| 1.3.6.1.4.1.4756.20.442.20.1.99 | ColumnedduRingInst1typestsRemoteB | read-only | current | EDD Series card u-Ring Type status |
| 1.3.6.1.4.1.4756.20.442.20.1.100 | ColumnedduRingInst1rolestsRemoteB | read-only | current | EDD Series card u-Ring Role status |
| 1.3.6.1.4.1.4756.20.442.20.1.101 | ColumnedduRingInst1EastPortstsRemoteB | read-only | current | EDD Series card u-Ring East port status |
| 1.3.6.1.4.1.4756.20.442.20.1.102 | ColumnedduRingInst1EaststsRemoteB | read-only | current | EDD Series card u-Ring East status |
| 1.3.6.1.4.1.4756.20.442.20.1.103 | ColumnedduRingInst1EastEdgestsRemoteB | read-only | current | EDD Series card u-Ring East edge status |
| 1.3.6.1.4.1.4756.20.442.20.1.104 | ColumnedduRingInst1WestPortstsRemoteB | read-only | current | EDD Series card u-Ring West edge status |
| 1.3.6.1.4.1.4756.20.442.20.1.105 | ColumnedduRingInst1WeststsRemoteB | read-only | current | EDD Series card u-Ring West status |
| 1.3.6.1.4.1.4756.20.442.20.1.106 | ColumnedduRingInst1WestEdgestsRemoteB | read-only | current | EDD Series card u-Ring West status |
| 1.3.6.1.4.1.4756.20.442.20.1.107 | ColumnedduRingInst1healthystsRemoteB | read-only | current | EDD Series card u-Ring healthy status None Fine Fault |
| 1.3.6.1.4.1.4756.20.442.20.1.108 | ColumnedduRingInst2IDstsRemoteB | read-only | current | EDD Series card u-Ring Instance2 ID status |
| 1.3.6.1.4.1.4756.20.442.20.1.109 | ColumnedduRingInst2typestsRemoteB | read-only | current | EDD Series card u-Ring Type status |
| 1.3.6.1.4.1.4756.20.442.20.1.110 | ColumnedduRingInst2rolestsRemoteB | read-only | current | EDD Series card u-Ring Role status |
| 1.3.6.1.4.1.4756.20.442.20.1.111 | ColumnedduRingInst2EastPortstsRemoteB | read-only | current | EDD Series card u-Ring East port status |
| 1.3.6.1.4.1.4756.20.442.20.1.112 | ColumnedduRingInst2EaststsRemoteB | read-only | current | EDD Series card u-Ring East status |
| 1.3.6.1.4.1.4756.20.442.20.1.113 | ColumnedduRingInst2EastEdgestsRemoteB | read-only | current | EDD Series card u-Ring East edge status |
| 1.3.6.1.4.1.4756.20.442.20.1.114 | ColumnedduRingInst2WestPortstsRemoteB | read-only | current | EDD Series card u-Ring West edge status |
| 1.3.6.1.4.1.4756.20.442.20.1.115 | ColumnedduRingInst2WeststsRemoteB | read-only | current | EDD Series card u-Ring West status |
| 1.3.6.1.4.1.4756.20.442.20.1.116 | ColumnedduRingInst2WestEdgestsRemoteB | read-only | current | EDD Series card u-Ring West status |
| 1.3.6.1.4.1.4756.20.442.20.1.117 | ColumnedduRingInst2healthystsRemoteB | read-only | current | EDD Series card u-Ring healthy status None Fine Fault |
| 1.3.6.1.4.1.4756.20.442.20.1.118 | ColumneddDeviceActiveRemoteB | read-only | current | EDD Series card u-Ring device active 0: Disable 1: Enable |
| 1.3.6.1.4.1.4756.20.442.20.1.119 | ColumneddFx1DDRemoteB | read-only | current | EDD Series card fiber port Digital Diagnostic function: 0:No 1:Yes |
| 1.3.6.1.4.1.4756.20.442.20.1.120 | ColumneddFx1DDVendorRemoteB | read-only | current | EDD Series card fiber port D/D information: Vendor name |
| 1.3.6.1.4.1.4756.20.442.20.1.121 | ColumneddFx1DDPartNoRemoteB | read-only | current | EDD Series card fiber port D/D information: Vendor part number |
| 1.3.6.1.4.1.4756.20.442.20.1.122 | ColumneddFx1DDFiberTypeRemoteB | read-only | current | EDD Series card fiber port D/D information: Fiber Type |
| 1.3.6.1.4.1.4756.20.442.20.1.123 | ColumneddFx1DDWaveLenRemoteB | read-only | current | EDD Series card fiber port D/D information: Wave length |
| 1.3.6.1.4.1.4756.20.442.20.1.124 | ColumneddFx1DDWaveLen2RemoteB | read-only | current | EDD Series card fiber port D/D information: Wave length 2 |
| 1.3.6.1.4.1.4756.20.442.20.1.125 | ColumneddFx1DDLinkLenRemoteB | read-only | current | EDD Series card fiber port D/D information: Link length |
| 1.3.6.1.4.1.4756.20.442.20.1.126 | ColumneddFx1DDLenUnitRemoteB | read-only | current | EDD Series card fiber port D/D information: Length Unit |
| 1.3.6.1.4.1.4756.20.442.20.1.127 | ColumneddFx1DDStatusRemoteB | read-only | current | EDD Series card fiber port D/D information: Status Support |
| 1.3.6.1.4.1.4756.20.442.20.1.128 | ColumneddFx1DDRxSensRemoteB | read-only | current | EDD Series card fiber port D/D information: Rx Sensitivity |
| 1.3.6.1.4.1.4756.20.442.20.1.129 | ColumneddFx1DDTxPWRRemoteB | read-only | current | EDD Series card fiber port D/D information: Tx power |
| 1.3.6.1.4.1.4756.20.442.20.1.130 | ColumneddFx1DDRxPWRRemoteB | read-only | current | EDD Series card fiber port D/D information: Rx power |
| 1.3.6.1.4.1.4756.20.442.20.1.131 | ColumneddFx1DDTempRemoteB | read-only | current | EDD Series card fiber port D/D information: Temperature in degree C |
| 1.3.6.1.4.1.4756.20.442.20.1.132 | ColumneddFx1DDPWRMarginRemoteB | read-only | current | EDD Series card fiber port D/D information: Power margin |
| 1.3.6.1.4.1.4756.20.442.20.1.133 | ColumneddFx1DDPWRLossRemoteB | read-only | current | EDD Series card fiber port D/D information: Power loss |
| 1.3.6.1.4.1.4756.20.442.20.1.134 | ColumneddFx2DDRemoteB | read-only | current | EDD Series card fiber2 Digital Diagnostic function: 0:NO 1:Yes |
| 1.3.6.1.4.1.4756.20.442.20.1.135 | ColumneddFx2DDVendorRemoteB | read-only | current | EDD Series card fiber2 D/D information: Vendor name |
| 1.3.6.1.4.1.4756.20.442.20.1.136 | ColumneddFx2DDPartNoRemoteB | read-only | current | EDD Series card fiber2 D/D information: Vendor part number |
| 1.3.6.1.4.1.4756.20.442.20.1.137 | ColumneddFx2DDFiberTypeRemoteB | read-only | current | EDD Series card fiber2 D/D information: Fiber Type |
| 1.3.6.1.4.1.4756.20.442.20.1.138 | ColumneddFx2DDWaveLenRemoteB | read-only | current | EDD Series card fiber2 D/D information: Wave length 1 |
| 1.3.6.1.4.1.4756.20.442.20.1.139 | ColumneddFx2DDWaveLen2RemoteB | read-only | current | EDD Series card fiber2 D/D information: Wave length 2 |
| 1.3.6.1.4.1.4756.20.442.20.1.140 | ColumneddFx2DDLinkLenRemoteB | read-only | current | EDD Series card fiber2 D/D information: Link length |
| 1.3.6.1.4.1.4756.20.442.20.1.141 | ColumneddFx2DDLenUnitRemoteB | read-only | current | EDD Series card fiber2 D/D information: Length Unit |
| 1.3.6.1.4.1.4756.20.442.20.1.142 | ColumneddFx2DDStatusRemoteB | read-only | current | EDD Series card fiber2 D/D information: Status Support |
| 1.3.6.1.4.1.4756.20.442.20.1.143 | ColumneddFx2DDRxSensRemoteB | read-only | current | EDD Series card fiber2 D/D information: Rx Sensitivity |
| 1.3.6.1.4.1.4756.20.442.20.1.144 | ColumneddFx2DDTxPWRRemoteB | read-only | current | EDD Series card fiber2 D/D information: Tx power |
| 1.3.6.1.4.1.4756.20.442.20.1.145 | ColumneddFx2DDRxPWRRemoteB | read-only | current | EDD Series card fiber2 D/D information: Rx power |
| 1.3.6.1.4.1.4756.20.442.20.1.146 | ColumneddFx2DDTempRemoteB | read-only | current | EDD Series card fiber2 D/D information: Temperature in degree C |
| 1.3.6.1.4.1.4756.20.442.20.1.147 | ColumneddFx2DDPWRMarginRemoteB | read-only | current | EDD Series card fiber2 D/D information: Power margin |
| 1.3.6.1.4.1.4756.20.442.20.1.148 | ColumneddFx2DDPWRLossRemoteB | read-only | current | EDD Series card fiber2 D/D information: Power loss |
| 1.3.6.1.4.1.4756.20.442.20.1.149 | ColumneddFx3DDRemoteB | read-only | current | EDD Series card fiber3 Digital Diagnostic function: 0:NO 1:Yes |
| 1.3.6.1.4.1.4756.20.442.20.1.150 | ColumneddFx3DDVendorRemoteB | read-only | current | EDD Series card fiber3 D/D information: Vendor name |
| 1.3.6.1.4.1.4756.20.442.20.1.151 | ColumneddFx3DDPartNoRemoteB | read-only | current | EDD Series card fiber32 D/D information: Vendor part number |
| 1.3.6.1.4.1.4756.20.442.20.1.152 | ColumneddFx3DDFiberTypeRemoteB | read-only | current | EDD Series card fiber3 D/D information: Fiber Type |
| 1.3.6.1.4.1.4756.20.442.20.1.153 | ColumneddFx3DDWaveLenRemoteB | read-only | current | EDD Series card fiber3 D/D information: Wave length 1 |
| 1.3.6.1.4.1.4756.20.442.20.1.154 | ColumneddFx3DDWaveLen2RemoteB | read-only | current | EDD Series card fiber3 D/D information: Wave length 2 |
| 1.3.6.1.4.1.4756.20.442.20.1.155 | ColumneddFx3DDLinkLenRemoteB | read-only | current | EDD Series card fiber3 D/D information: Link length |
| 1.3.6.1.4.1.4756.20.442.20.1.156 | ColumneddFx3DDLenUnitRemoteB | read-only | current | EDD Series card fiber3 D/D information: Length Unit |
| 1.3.6.1.4.1.4756.20.442.20.1.157 | ColumneddFx3DDStatusRemoteB | read-only | current | EDD Series card fiber3 D/D information: Status Support |
| 1.3.6.1.4.1.4756.20.442.20.1.158 | ColumneddFx3DDRxSensRemoteB | read-only | current | EDD Series card fiber3 D/D information: Rx Sensitivity |
| 1.3.6.1.4.1.4756.20.442.20.1.159 | ColumneddFx3DDTxPWRRemoteB | read-only | current | EDD Series card fiber3 D/D information: Tx power |
| 1.3.6.1.4.1.4756.20.442.20.1.160 | ColumneddFx3DDRxPWRRemoteB | read-only | current | EDD Series card fiber3 D/D information: Rx power |
| 1.3.6.1.4.1.4756.20.442.20.1.161 | ColumneddFx3DDTempRemoteB | read-only | current | EDD Series card fiber3 D/D information: Temperature in degree C |
| 1.3.6.1.4.1.4756.20.442.20.1.162 | ColumneddFx3DDPWRMarginRemoteB | read-only | current | EDD Series card fiber3 D/D information: Power margin |
| 1.3.6.1.4.1.4756.20.442.20.1.163 | ColumneddFx3DDPWRLossRemoteB | read-only | current | EDD Series card fiber3 D/D information: Power loss |
| 1.3.6.1.4.1.4756.20.442.20.1.164 | ColumneddTestRemoteB | read-only | current | EDD Series card test led sts: 0: Off 1: On |
| 1.3.6.1.4.1.4756.20.442.20.1.165 | ColumneddClearPortCounterRemoteB | read-write | current | EDD Series card clear port counter: 0: Off 1: Action |
| 1.3.6.1.4.1.4756.20.442.20.1.166 | ColumneddAggrSourceMACAddrRemoteB | read-write | current | EDD Series card Aggregation Mode Configuration: Source MAC Address 0: No 1: Yes |
| 1.3.6.1.4.1.4756.20.442.20.1.167 | ColumneddAggrDestinationMACAddrRemoteB | read-write | current | EDD Series card Aggregation Mode Configuration: Destination MAC Address 0: No 1: Yes |
| 1.3.6.1.4.1.4756.20.442.20.1.168 | ColumneddAggrIPAddrRemoteB | read-write | current | EDD Series card Aggregation Mode Configuration: IP Address 0: No 1: Yes |
| 1.3.6.1.4.1.4756.20.442.20.1.169 | ColumneddAggrTCPUDPPortNumRemoteB | read-write | current | EDD Series card Aggregation Mode Configuration: TCP/UDP Port Number 0: No 1: Yes |
| 1.3.6.1.4.1.4756.20.442.20.1.170 | ColumneddAggrGroupPort1ConfRemoteB | read-write | current | EDD Series card Aggregation Group Port1 Configuration: 0: Normal 1: ID1 2: ID2 |
| 1.3.6.1.4.1.4756.20.442.20.1.171 | ColumneddAggrGroupPort2ConfRemoteB | read-write | current | EDD Series card Aggregation Group Port2 Configuration: 0: Normal 1: ID1 2: ID2 |
| 1.3.6.1.4.1.4756.20.442.20.1.172 | ColumneddAggrGroupPort3ConfRemoteB | read-write | current | EDD Series card Aggregation Group Port3 Configuration: 0: Normal 1: ID1 2: ID2 |
| 1.3.6.1.4.1.4756.20.442.20.1.173 | ColumneddAggrGroupPort4ConfRemoteB | read-write | current | EDD Series card Aggregation Group Port4 Configuration: 0: Normal 1: ID1 2: ID2 |
| 1.3.6.1.4.1.4756.20.442.20.1.174 | ColumneddPort1LACPEnabledRemoteB | read-write | current | EDD Series card Port1 LACP Enabled: 0: No 1: Yes |
| 1.3.6.1.4.1.4756.20.442.20.1.175 | ColumneddPort1LACPKEYRemoteB | read-write | current | EDD Series card Port1 LACP Key value: The Key value incurred by the port, range 0-65535.The value of 0 means auto. |
| 1.3.6.1.4.1.4756.20.442.20.1.176 | ColumneddPort1LACPRoleRemoteB | read-write | current | EDD Series card Port1 LACP Role: 0: Passive 1: Active |
| 1.3.6.1.4.1.4756.20.442.20.1.177 | ColumneddPort1LACPTimeOutRemoteB | read-write | current | EDD Series card Port1 LACP Time out: 0: Slow 1: Fast |
| 1.3.6.1.4.1.4756.20.442.20.1.178 | ColumneddPort1LACPPrioRemoteB | read-write | current | EDD Series card Port1 LACP priority: The Key value incurred by the port, range 1-65535. |
| 1.3.6.1.4.1.4756.20.442.20.1.179 | ColumneddPort2LACPEnabledRemoteB | read-write | current | EDD Series card Port2 LACP Enabled: 0: No 1: Yes |
| 1.3.6.1.4.1.4756.20.442.20.1.180 | ColumneddPort2LACPKEYRemoteB | read-write | current | EDD Series card Port2 LACP Key value: The Key value incurred by the port, range 0-65535.The value of 0 means auto. |
| 1.3.6.1.4.1.4756.20.442.20.1.181 | ColumneddPort2LACPRoleRemoteB | read-write | current | EDD Series card Port2 LACP Role: 0: Passive 1: Active |
| 1.3.6.1.4.1.4756.20.442.20.1.182 | ColumneddPort2LACPTimeOutRemoteB | read-write | current | EDD Series card Port2 LACP Time out: 0: Slow 1: Fast |
| 1.3.6.1.4.1.4756.20.442.20.1.183 | ColumneddPort2LACPPrioRemoteB | read-write | current | EDD Series card Port2 LACP priority: The Key value incurred by the port, range 1-65535. |
| 1.3.6.1.4.1.4756.20.442.20.1.184 | ColumneddPort3LACPEnabledRemoteB | read-write | current | EDD Series card Port3 LACP Enabled: 0: No 1: Yes |
| 1.3.6.1.4.1.4756.20.442.20.1.185 | ColumneddPort3LACPKEYRemoteB | read-write | current | EDD Series card Port3 LACP Key value: The Key value incurred by the port, range 0-65535.The value of 0 means auto. |
| 1.3.6.1.4.1.4756.20.442.20.1.186 | ColumneddPort3LACPRoleRemoteB | read-write | current | EDD Series card Port3 LACP Role: 0: Passive 1: Active |
| 1.3.6.1.4.1.4756.20.442.20.1.187 | ColumneddPort3LACPTimeOutRemoteB | read-write | current | EDD Series card Port3 LACP Time out: 0: Slow 1: Fast |
| 1.3.6.1.4.1.4756.20.442.20.1.188 | ColumneddPort3LACPPrioRemoteB | read-write | current | EDD Series card Port3 LACP priority: The Key value incurred by the port, range 1-65535. |
| 1.3.6.1.4.1.4756.20.442.20.1.189 | ColumneddPort4LACPEnabledRemoteB | read-write | current | EDD Series card Port4 LACP Enabled: 0: No 1: Yes |
| 1.3.6.1.4.1.4756.20.442.20.1.190 | ColumneddPort4LACPKEYRemoteB | read-write | current | EDD Series card Port4 LACP Key value: The Key value incurred by the port, range 0-65535.The value of 0 means auto. |
| 1.3.6.1.4.1.4756.20.442.20.1.191 | ColumneddPort4LACPRoleRemoteB | read-write | current | EDD Series card Port4 LACP Role: 0: Passive 1: Active |
| 1.3.6.1.4.1.4756.20.442.20.1.192 | ColumneddPort4LACPTimeOutRemoteB | read-write | current | EDD Series card Port4 LACP Time out: 0: Slow 1: Fast |
| 1.3.6.1.4.1.4756.20.442.20.1.193 | ColumneddPort4LACPPrioRemoteB | read-write | current | EDD Series card Port4 LACP priority: The Key value incurred by the port, range 1-65535. |
| 1.3.6.1.4.1.4756.20.442.20.1.194 | ColumneddPort1LACPstsRemoteB | read-only | current | EDD Series card Port1 LACP status: 0: No 1: Yes 2: Standby |
| 1.3.6.1.4.1.4756.20.442.20.1.195 | ColumneddPort1LACPKEYstsRemoteB | read-only | current | EDD Series card Port1 LACP status: Key |
| 1.3.6.1.4.1.4756.20.442.20.1.196 | ColumneddPort1LACPAggrIDstsRemoteB | read-only | current | EDD Series card Port1 LACP status: Aggr ID |
| 1.3.6.1.4.1.4756.20.442.20.1.197 | ColumneddPort1LACPParnterSysIDstsRemoteB | read-only | current | EDD Series card Port1 LACP status: Parnter System ID |
| 1.3.6.1.4.1.4756.20.442.20.1.198 | ColumneddPort1LACPParnterPortstsRemoteB | read-only | current | EDD Series card Port1 LACP status: Parnter Port Status |
| 1.3.6.1.4.1.4756.20.442.20.1.199 | ColumneddPort1LACPParnterProistsRemoteB | read-only | current | EDD Series card Port1 LACP status: Parnter Priority |
| 1.3.6.1.4.1.4756.20.442.20.1.200 | ColumneddPort2LACPstsRemoteB | read-only | current | EDD Series card Port2 LACP status: 0: No 1: Yes 2: Standby |
| 1.3.6.1.4.1.4756.20.442.20.1.201 | ColumneddPort2LACPKEYstsRemoteB | read-only | current | EDD Series card Port2 LACP status: Key |
| 1.3.6.1.4.1.4756.20.442.20.1.202 | ColumneddPort2LACPAggrIDstsRemoteB | read-only | current | EDD Series card Port2 LACP status: Aggr ID |
| 1.3.6.1.4.1.4756.20.442.20.1.203 | ColumneddPort2LACPParnterSysIDstsRemoteB | read-only | current | EDD Series card Port2 LACP status: Parnter System ID |
| 1.3.6.1.4.1.4756.20.442.20.1.204 | ColumneddPort2LACPParnterPortstsRemoteB | read-only | current | EDD Series card Port2 LACP status: Parnter Port Status |
| 1.3.6.1.4.1.4756.20.442.20.1.205 | ColumneddPort2LACPParnterProistsRemoteB | read-only | current | EDD Series card Port2 LACP status: Parnter Priority |
| 1.3.6.1.4.1.4756.20.442.20.1.206 | ColumneddPort3LACPstsRemoteB | read-only | current | EDD Series card Port3 LACP status: 0: No 1: Yes 2: Standby |
| 1.3.6.1.4.1.4756.20.442.20.1.207 | ColumneddPort3LACPKEYstsRemoteB | read-only | current | EDD Series card Port3 LACP status: Key |
| 1.3.6.1.4.1.4756.20.442.20.1.208 | ColumneddPort3LACPAggrIDstsRemoteB | read-only | current | EDD Series card Port3 LACP status: Aggr ID |
| 1.3.6.1.4.1.4756.20.442.20.1.209 | ColumneddPort3LACPParnterSysIDstsRemoteB | read-only | current | EDD Series card Port3 LACP status: Parnter System ID |
| 1.3.6.1.4.1.4756.20.442.20.1.210 | ColumneddPort3LACPParnterPortstsRemoteB | read-only | current | EDD Series card Port3 LACP status: Parnter Port Status |
| 1.3.6.1.4.1.4756.20.442.20.1.211 | ColumneddPort3LACPParnterProistsRemoteB | read-only | current | EDD Series card Port3 LACP status: Parnter Priority |
| 1.3.6.1.4.1.4756.20.442.20.1.212 | ColumneddPort4LACPstsRemoteB | read-only | current | EDD Series card Port4 LACP status: 0: No 1: Yes 2: Standby |
| 1.3.6.1.4.1.4756.20.442.20.1.213 | ColumneddPort4LACPKEYstsRemoteB | read-only | current | EDD Series card Port4 LACP status: Key |
| 1.3.6.1.4.1.4756.20.442.20.1.214 | ColumneddPort4LACPAggrIDstsRemoteB | read-only | current | EDD Series card Port4 LACP status: Aggr ID |
| 1.3.6.1.4.1.4756.20.442.20.1.215 | ColumneddPort4LACPParnterSysIDstsRemoteB | read-only | current | EDD Series card Port4 LACP status: Parnter System ID |
| 1.3.6.1.4.1.4756.20.442.20.1.216 | ColumneddPort4LACPParnterPortstsRemoteB | read-only | current | EDD Series card Port4 LACP status: Parnter Port Status |
| 1.3.6.1.4.1.4756.20.442.20.1.217 | ColumneddPort4LACPParnterProistsRemoteB | read-only | current | EDD Series card Port4 LACP status: Parnter Priority |
| 1.3.6.1.4.1.4756.20.442.20.1.218 | ColumneddOAMPort1EnableRemoteB | read-write | current | EDD Series card Port1 OAM: 0: Off 1: On |
| 1.3.6.1.4.1.4756.20.442.20.1.219 | ColumneddOAMPort1ModeRemoteB | read-write | current | EDD Series card Port1 OAM: 0: Passive 1: Active |
| 1.3.6.1.4.1.4756.20.442.20.1.220 | ColumneddOAMPort1LoopBackRemoteB | read-write | current | EDD Series card Port1 OAM LoopBack: 0: Off 1: On |
| 1.3.6.1.4.1.4756.20.442.20.1.221 | ColumneddOAMPort1LinkMonitorRemoteB | read-write | current | EDD Series card Port1 OAM Link Monitor: 0: Off 1: On |
| 1.3.6.1.4.1.4756.20.442.20.1.222 | ColumneddOAMPort1MIBRetrievalRemoteB | read-write | current | EDD Series card Port1 OAM MIB Retrieval: 0: Off 1: On |
| 1.3.6.1.4.1.4756.20.442.20.1.223 | ColumneddOAMPort1LoopBackOPRemoteB | read-only | current | EDD Series card Port1 OAM LoopBack operation: 0: Off 1: On |
| 1.3.6.1.4.1.4756.20.442.20.1.224 | ColumneddOAMPort2EnableRemoteB | read-write | current | EDD Series card Port2 OAM: 0: Off 1: On |
| 1.3.6.1.4.1.4756.20.442.20.1.225 | ColumneddOAMPort2ModeRemoteB | read-write | current | EDD Series card Port2 OAM: 0: Passive 1: Active |
| 1.3.6.1.4.1.4756.20.442.20.1.226 | ColumneddOAMPort2LoopBackRemoteB | read-write | current | EDD Series card Port2 OAM LoopBack: 0: Off 1: On |
| 1.3.6.1.4.1.4756.20.442.20.1.227 | ColumneddOAMPort2LinkMonitorRemoteB | read-write | current | EDD Series card Port2 OAM Link Monitor: 0: Off 1: On |
| 1.3.6.1.4.1.4756.20.442.20.1.228 | ColumneddOAMPort2MIBRetrievalRemoteB | read-write | current | EDD Series card Port2 OAM MIB Retrieval: 0: Off 1: On |
| 1.3.6.1.4.1.4756.20.442.20.1.229 | ColumneddOAMPort2LoopBackOPRemoteB | read-only | current | EDD Series card Port2 OAM LoopBack operation: 0: Off 1: On |
| 1.3.6.1.4.1.4756.20.442.20.1.230 | ColumneddOAMPort3EnableRemoteB | read-write | current | EDD Series card Port3 OAM: 0: Off 1: On |
| 1.3.6.1.4.1.4756.20.442.20.1.231 | ColumneddOAMPort3ModeRemoteB | read-write | current | EDD Series card Port3 OAM: 0: Passive 1: Active |
| 1.3.6.1.4.1.4756.20.442.20.1.232 | ColumneddOAMPort3LoopBackRemoteB | read-write | current | EDD Series card Port3 OAM: 0: Off 1: On |
| 1.3.6.1.4.1.4756.20.442.20.1.233 | ColumneddOAMPort3LinkMonitorRemoteB | read-write | current | EDD Series card Port3 OAM Link Monitor: 0: Off 1: On |
| 1.3.6.1.4.1.4756.20.442.20.1.234 | ColumneddOAMPort3MIBRetrievalRemoteB | read-write | current | EDD Series card Port3 OAM MIB Retrieval: 0: Off 1: On |
| 1.3.6.1.4.1.4756.20.442.20.1.235 | ColumneddOAMPort3LoopBackOPRemoteB | read-only | current | EDD Series card Port3 OAM LoopBack operation: 0: Disable 1: Enable |
| 1.3.6.1.4.1.4756.20.442.20.1.236 | ColumneddOAMPort4EnableRemoteB | read-write | current | EDD Series card Port4 OAM: 0: Off 1: On |
| 1.3.6.1.4.1.4756.20.442.20.1.237 | ColumneddOAMPort4ModeRemoteB | read-write | current | EDD Series card Port4 OAM: 0: Passive 1: Active |
| 1.3.6.1.4.1.4756.20.442.20.1.238 | ColumneddOAMPort4LoopBackRemoteB | read-write | current | EDD Series card Port4 OAM: 0: Off 1: On |
| 1.3.6.1.4.1.4756.20.442.20.1.239 | ColumneddOAMPort4LinkMonitorRemoteB | read-write | current | EDD Series card Port4 OAM Link Monitor: 0: Off 1: On |
| 1.3.6.1.4.1.4756.20.442.20.1.240 | ColumneddOAMPort4MIBRetrievalRemoteB | read-write | current | EDD Series card Port4 OAM MIB Retrieval: 0: Off 1: On |
| 1.3.6.1.4.1.4756.20.442.20.1.241 | ColumneddOAMPort4LoopBackOPRemoteB | read-only | current | EDD Series card Port4 OAM LoopBack operation: 0: On 1: Off |
| 1.3.6.1.4.1.4756.20.442.20.1.242 | ColumneddPort1EFEErrorWindowRemoteB | read-write | current | EDD Series card Port1 Link Event Configuration: Error Frame Event - Error Window |
| 1.3.6.1.4.1.4756.20.442.20.1.243 | ColumneddPort1EFEErrorThresholdRemoteB | read-write | current | EDD Series card Port1 Link Event Configuration: Error Frame Event - Error Threshold |
| 1.3.6.1.4.1.4756.20.442.20.1.244 | ColumneddPort1SPEEErrorWindowRemoteB | read-write | current | EDD Series card Port1 Link Event Configuration: Symbol Period Error Event - Error Window |
| 1.3.6.1.4.1.4756.20.442.20.1.245 | ColumneddPort1SPEEErrorThresholdRemoteB | read-write | current | EDD Series card Port1 Link Event Configuration: Symbol Period Error Event - Error Threshold |
| 1.3.6.1.4.1.4756.20.442.20.1.246 | ColumneddPort1SSEErrorWindowRemoteB | read-write | current | EDD Series card Port1 Link Event Configuration: Seconds Summary Event - Error Window |
| 1.3.6.1.4.1.4756.20.442.20.1.247 | ColumneddPort1SSEErrorThresholdRemoteB | read-write | current | EDD Series card Port1 Link Event Configuration: Seconds Summary Event - Error Threshold |
| 1.3.6.1.4.1.4756.20.442.20.1.248 | ColumneddPort2EFEErrorWindowRemoteB | read-write | current | EDD Series card Port2 Link Event Configuration: Error Frame Event - Error Window |
| 1.3.6.1.4.1.4756.20.442.20.1.249 | ColumneddPort2EFEErrorThresholdRemoteB | read-write | current | EDD Series card Port2 Link Event Configuration: Error Frame Event - Error Threshold |
| 1.3.6.1.4.1.4756.20.442.20.1.250 | ColumneddPort2SPEEErrorWindowRemoteB | read-write | current | EDD Series card Port2 Link Event Configuration: Symbol Period Error Event - Error Window |
| 1.3.6.1.4.1.4756.20.442.20.1.251 | ColumneddPort2SPEEErrorThresholdRemoteB | read-write | current | EDD Series card Port2 Link Event Configuration: Symbol Period Error Event - Error Threshold |
| 1.3.6.1.4.1.4756.20.442.20.1.252 | ColumneddPort2SSEErrorWindowRemoteB | read-write | current | EDD Series card Port2 Link Event Configuration: Seconds Summary Event - Error Window |
| 1.3.6.1.4.1.4756.20.442.20.1.253 | ColumneddPort2SSEErrorThresholdRemoteB | read-write | current | EDD Series card Port2 Link Event Configuration: Seconds Summary Event - Error Threshold |
| 1.3.6.1.4.1.4756.20.442.20.1.254 | ColumneddPort3EFEErrorWindowRemoteB | read-write | current | EDD Series card Port3 Link Event Configuration: Error Frame Event - Error Window |
| 1.3.6.1.4.1.4756.20.442.20.1.255 | ColumneddPort3EFEErrorThresholdRemoteB | read-write | current | EDD Series card Port3 Link Event Configuration: Error Frame Event - Error Threshold |
| 1.3.6.1.4.1.4756.20.442.20.1.256 | ColumneddPort3SPEEErrorWindowRemoteB | read-write | current | EDD Series card Port3 Link Event Configuration: Symbol Period Error Event - Error Window |
| 1.3.6.1.4.1.4756.20.442.20.1.257 | ColumneddPort3SPEEErrorThresholdRemoteB | read-write | current | EDD Series card Port3 Link Event Configuration: Symbol Period Error Event - Error Threshold |
| 1.3.6.1.4.1.4756.20.442.20.1.258 | ColumneddPort3SSEErrorWindowRemoteB | read-write | current | EDD Series card Port3 Link Event Configuration: Seconds Summary Event - Error Window |
| 1.3.6.1.4.1.4756.20.442.20.1.259 | ColumneddPort3SSEErrorThresholdRemoteB | read-write | current | EDD Series card Port3 Link Event Configuration: Seconds Summary Event - Error Threshold |
| 1.3.6.1.4.1.4756.20.442.20.1.260 | ColumneddPort4EFEErrorWindowRemoteB | read-write | current | EDD Series card Port4 Link Event Configuration: Error Frame Event - Error Window |
| 1.3.6.1.4.1.4756.20.442.20.1.261 | ColumneddPort4EFEErrorThresholdRemoteB | read-write | current | EDD Series card Port4 Link Event Configuration: Error Frame Event - Error Threshold |
| 1.3.6.1.4.1.4756.20.442.20.1.262 | ColumneddPort4SPEEErrorWindowRemoteB | read-write | current | EDD Series card Port4 Link Event Configuration: Symbol Period Error Event - Error Window |
| 1.3.6.1.4.1.4756.20.442.20.1.263 | ColumneddPort4SPEEErrorThresholdRemoteB | read-write | current | EDD Series card Port4 Link Event Configuration: Symbol Period Error Event - Error Threshold |
| 1.3.6.1.4.1.4756.20.442.20.1.264 | ColumneddPort4SSEErrorWindowRemoteB | read-write | current | EDD Series card Port4 Link Event Configuration: Seconds Summary Event - Error Window |
| 1.3.6.1.4.1.4756.20.442.20.1.265 | ColumneddPort4SSEErrorThresholdRemoteB | read-write | current | EDD Series card Port4 Link Event Configuration: Seconds Summary Event - Error Threshold |
| 1.3.6.1.4.1.4756.20.442.20.1.266 | ColumneddPort1RxOAMInfoPDURemoteB | read-only | current | EDD Series card Port1 Detailed Link OAM Statistics: Rx OAM Information PDU's |
| 1.3.6.1.4.1.4756.20.442.20.1.267 | ColumneddPort1RxUniqueErrorEventRemoteB | read-only | current | EDD Series card Port1 Detailed Link OAM Statistics: Rx Unique Error Event Notificatio |
| 1.3.6.1.4.1.4756.20.442.20.1.268 | ColumneddPort1RxDuplicateErrorEventRemoteB | read-only | current | EDD Series card Port1 Detailed Link OAM Statistics: Rx Duplicate Error Event Notification |
| 1.3.6.1.4.1.4756.20.442.20.1.269 | ColumneddPort1RxLoopBackControlRemoteB | read-only | current | EDD Series card Port1 Detailed Link OAM Statistics: Rx Loopback Control |
| 1.3.6.1.4.1.4756.20.442.20.1.270 | ColumneddPort1RxVariableRequestRemoteB | read-only | current | EDD Series card Port1 Detailed Link OAM Statistics: Rx Variable Request |
| 1.3.6.1.4.1.4756.20.442.20.1.271 | ColumneddPort1RxVariableResponseRemoteB | read-only | current | EDD Series card Port1 Detailed Link OAM Statistics: Rx Variable Response |
| 1.3.6.1.4.1.4756.20.442.20.1.272 | ColumneddPort1RxOrgSpecificPDURemoteB | read-only | current | EDD Series card Port1 Detailed Link OAM Statistics: Rx Org Specific PDU's |
| 1.3.6.1.4.1.4756.20.442.20.1.273 | ColumneddPort1RxUnsupportedCodesRemoteB | read-only | current | EDD Series card Port1 Detailed Link OAM Statistics: Rx Unsupported Codes |
| 1.3.6.1.4.1.4756.20.442.20.1.274 | ColumneddPort1RxLinkFaultPDURemoteB | read-only | current | EDD Series card Port1 Detailed Link OAM Statistics: Rx Link Fault PDU's |
| 1.3.6.1.4.1.4756.20.442.20.1.275 | ColumneddPort1RxDyingGaspRemoteB | read-only | current | EDD Series card Port1 Detailed Link OAM Statistics: Rx Dying Gasp |
| 1.3.6.1.4.1.4756.20.442.20.1.276 | ColumneddPort1RxCriticalEventPDURemoteB | read-only | current | EDD Series card Port1 Detailed Link OAM Statistics: Rx Dying Gasp |
| 1.3.6.1.4.1.4756.20.442.20.1.277 | ColumneddPort1TxOAMInfoPDURemoteB | read-only | current | EDD Series card Port1 Detailed Link OAM Statistics: Tx OAM Information PDU's |
| 1.3.6.1.4.1.4756.20.442.20.1.278 | ColumneddPort1TxUniqueErrorEventRemoteB | read-only | current | EDD Series card Port1 Detailed Link OAM Statistics: Tx Unique Error Event Notificatio |
| 1.3.6.1.4.1.4756.20.442.20.1.279 | ColumneddPort1TxDuplicateErrorEventRemoteB | read-only | current | EDD Series card Port1 Detailed Link OAM Statistics: Tx Duplicate Error Event Notification |
| 1.3.6.1.4.1.4756.20.442.20.1.280 | ColumneddPort1TxLoopBackControlRemoteB | read-only | current | EDD Series card Port1 Detailed Link OAM Statistics: Tx Loopback Control |
| 1.3.6.1.4.1.4756.20.442.20.1.281 | ColumneddPort1TxVariableRequestRemoteB | read-only | current | EDD Series card Port1 Detailed Link OAM Statistics: Tx Variable Request |
| 1.3.6.1.4.1.4756.20.442.20.1.282 | ColumneddPort1TxVariableResponseRemoteB | read-only | current | EDD Series card Port1 Detailed Link OAM Statistics: Tx Variable Response |
| 1.3.6.1.4.1.4756.20.442.20.1.283 | ColumneddPort1TxOrgSpecificPDURemoteB | read-only | current | EDD Series card Port1 Detailed Link OAM Statistics: Tx Org Specific PDU's |
| 1.3.6.1.4.1.4756.20.442.20.1.284 | ColumneddPort1TxUnsupportedCodesRemoteB | read-only | current | EDD Series card Port1 Detailed Link OAM Statistics: Tx Unsupported Codes |
| 1.3.6.1.4.1.4756.20.442.20.1.285 | ColumneddPort1TxLinkFaultPDURemoteB | read-only | current | EDD Series card Port1 Detailed Link OAM Statistics: Tx Link Fault PDU's |
| 1.3.6.1.4.1.4756.20.442.20.1.286 | ColumneddPort1TxDyingGaspRemoteB | read-only | current | EDD Series card Port1 Detailed Link OAM Statistics: Tx Dying Gasp |
| 1.3.6.1.4.1.4756.20.442.20.1.287 | ColumneddPort1TxCriticalEventPDURemoteB | read-only | current | EDD Series card Port1 Detailed Link OAM Statistics: Tx Dying Gasp |
| 1.3.6.1.4.1.4756.20.442.20.1.288 | ColumneddPort2RxOAMInfoPDURemoteB | read-only | current | EDD Series card Port2 Detailed Link OAM Statistics: Rx OAM Information PDU's |
| 1.3.6.1.4.1.4756.20.442.20.1.289 | ColumneddPort2RxUniqueErrorEventRemoteB | read-only | current | EDD Series card Port2 Detailed Link OAM Statistics: Rx Unique Error Event Notificatio |
| 1.3.6.1.4.1.4756.20.442.20.1.290 | ColumneddPort2RxDuplicateErrorEventRemoteB | read-only | current | EDD Series card Port2 Detailed Link OAM Statistics: Rx Duplicate Error Event Notification |
| 1.3.6.1.4.1.4756.20.442.20.1.291 | ColumneddPort2RxLoopBackControlRemoteB | read-only | current | EDD Series card Port2 Detailed Link OAM Statistics: Rx Loopback Control |
| 1.3.6.1.4.1.4756.20.442.20.1.292 | ColumneddPort2RxVariableRequestRemoteB | read-only | current | EDD Series card Port2 Detailed Link OAM Statistics: Rx Variable Request |
| 1.3.6.1.4.1.4756.20.442.20.1.293 | ColumneddPort2RxVariableResponseRemoteB | read-only | current | EDD Series card Port2 Detailed Link OAM Statistics: Rx Variable Response |
| 1.3.6.1.4.1.4756.20.442.20.1.294 | ColumneddPort2RxOrgSpecificPDURemoteB | read-only | current | EDD Series card Port2 Detailed Link OAM Statistics: Rx Org Specific PDU's |
| 1.3.6.1.4.1.4756.20.442.20.1.295 | ColumneddPort2RxUnsupportedCodesRemoteB | read-only | current | EDD Series card Port2 Detailed Link OAM Statistics: Rx Unsupported Codes |
| 1.3.6.1.4.1.4756.20.442.20.1.296 | ColumneddPort2RxLinkFaultPDURemoteB | read-only | current | EDD Series card Port2 Detailed Link OAM Statistics: Rx Link Fault PDU's |
| 1.3.6.1.4.1.4756.20.442.20.1.297 | ColumneddPort2RxDyingGaspRemoteB | read-only | current | EDD Series card Port2 Detailed Link OAM Statistics: Rx Dying Gasp |
| 1.3.6.1.4.1.4756.20.442.20.1.298 | ColumneddPort2RxCriticalEventPDURemoteB | read-only | current | EDD Series card Port2 Detailed Link OAM Statistics: Rx Dying Gasp |
| 1.3.6.1.4.1.4756.20.442.20.1.299 | ColumneddPort2TxOAMInfoPDURemoteB | read-only | current | EDD Series card Port2 Detailed Link OAM Statistics: Tx OAM Information PDU's |
| 1.3.6.1.4.1.4756.20.442.20.1.300 | ColumneddPort2TxUniqueErrorEventRemoteB | read-only | current | EDD Series card Port2 Detailed Link OAM Statistics: Tx Unique Error Event Notificatio |
| 1.3.6.1.4.1.4756.20.442.20.1.301 | ColumneddPort2TxDuplicateErrorEventRemoteB | read-only | current | EDD Series card Port2 Detailed Link OAM Statistics: Tx Duplicate Error Event Notification |
| 1.3.6.1.4.1.4756.20.442.20.1.302 | ColumneddPort2TxLoopBackControlRemoteB | read-only | current | EDD Series card Port2 Detailed Link OAM Statistics: Tx Loopback Control |
| 1.3.6.1.4.1.4756.20.442.20.1.303 | ColumneddPort2TxVariableRequestRemoteB | read-only | current | EDD Series card Port2 Detailed Link OAM Statistics: Tx Variable Request |
| 1.3.6.1.4.1.4756.20.442.20.1.304 | ColumneddPort2TxVariableResponseRemoteB | read-only | current | EDD Series card Port2 Detailed Link OAM Statistics: Tx Variable Response |
| 1.3.6.1.4.1.4756.20.442.20.1.305 | ColumneddPort2TxOrgSpecificPDURemoteB | read-only | current | EDD Series card Port2 Detailed Link OAM Statistics: Tx Org Specific PDU's |
| 1.3.6.1.4.1.4756.20.442.20.1.306 | ColumneddPort2TxUnsupportedCodesRemoteB | read-only | current | EDD Series card Port2 Detailed Link OAM Statistics: Tx Unsupported Codes |
| 1.3.6.1.4.1.4756.20.442.20.1.307 | ColumneddPort2TxLinkFaultPDURemoteB | read-only | current | EDD Series card Port2 Detailed Link OAM Statistics: Tx Link Fault PDU's |
| 1.3.6.1.4.1.4756.20.442.20.1.308 | ColumneddPort2TxDyingGaspRemoteB | read-only | current | EDD Series card Port2 Detailed Link OAM Statistics: Tx Dying Gasp |
| 1.3.6.1.4.1.4756.20.442.20.1.309 | ColumneddPort2TxCriticalEventPDURemoteB | read-only | current | EDD Series card Port2 Detailed Link OAM Statistics: Tx Dying Gasp |
| 1.3.6.1.4.1.4756.20.442.20.1.310 | ColumneddPort3RxOAMInfoPDURemoteB | read-only | current | EDD Series card Port3 Detailed Link OAM Statistics: Rx OAM Information PDU's |
| 1.3.6.1.4.1.4756.20.442.20.1.311 | ColumneddPort3RxUniqueErrorEventRemoteB | read-only | current | EDD Series card Port3 Detailed Link OAM Statistics: Rx Unique Error Event Notificatio |
| 1.3.6.1.4.1.4756.20.442.20.1.312 | ColumneddPort3RxDuplicateErrorEventRemoteB | read-only | current | EDD Series card Port3 Detailed Link OAM Statistics: Rx Duplicate Error Event Notification |
| 1.3.6.1.4.1.4756.20.442.20.1.313 | ColumneddPort3RxLoopBackControlRemoteB | read-only | current | EDD Series card Port3 Detailed Link OAM Statistics: Rx Loopback Control |
| 1.3.6.1.4.1.4756.20.442.20.1.314 | ColumneddPort3RxVariableRequestRemoteB | read-only | current | EDD Series card Port3 Detailed Link OAM Statistics: Rx Variable Request |
| 1.3.6.1.4.1.4756.20.442.20.1.315 | ColumneddPort3RxVariableResponseRemoteB | read-only | current | EDD Series card Port3 Detailed Link OAM Statistics: Rx Variable Response |
| 1.3.6.1.4.1.4756.20.442.20.1.316 | ColumneddPort3RxOrgSpecificPDURemoteB | read-only | current | EDD Series card Port3 Detailed Link OAM Statistics: Rx Org Specific PDU's |
| 1.3.6.1.4.1.4756.20.442.20.1.317 | ColumneddPort3RxUnsupportedCodesRemoteB | read-only | current | EDD Series card Port3 Detailed Link OAM Statistics: Rx Unsupported Codes |
| 1.3.6.1.4.1.4756.20.442.20.1.318 | ColumneddPort3RxLinkFaultPDURemoteB | read-only | current | EDD Series card Port3 Detailed Link OAM Statistics: Rx Link Fault PDU's |
| 1.3.6.1.4.1.4756.20.442.20.1.319 | ColumneddPort3RxDyingGaspRemoteB | read-only | current | EDD Series card Port3 Detailed Link OAM Statistics: Rx Dying Gasp |
| 1.3.6.1.4.1.4756.20.442.20.1.320 | ColumneddPort3RxCriticalEventPDURemoteB | read-only | current | EDD Series card Port3 Detailed Link OAM Statistics: Rx Dying Gasp |
| 1.3.6.1.4.1.4756.20.442.20.1.321 | ColumneddPort3TxOAMInfoPDURemoteB | read-only | current | EDD Series card Port3 Detailed Link OAM Statistics: Tx OAM Information PDU's |
| 1.3.6.1.4.1.4756.20.442.20.1.322 | ColumneddPort3TxUniqueErrorEventRemoteB | read-only | current | EDD Series card Port3 Detailed Link OAM Statistics: Tx Unique Error Event Notificatio |
| 1.3.6.1.4.1.4756.20.442.20.1.323 | ColumneddPort3TxDuplicateErrorEventRemoteB | read-only | current | EDD Series card Port3 Detailed Link OAM Statistics: Tx Duplicate Error Event Notification |
| 1.3.6.1.4.1.4756.20.442.20.1.324 | ColumneddPort3TxLoopBackControlRemoteB | read-only | current | EDD Series card Port3 Detailed Link OAM Statistics: Tx Loopback Control |
| 1.3.6.1.4.1.4756.20.442.20.1.325 | ColumneddPort3TxVariableRequestRemoteB | read-only | current | EDD Series card Port3 Detailed Link OAM Statistics: Tx Variable Request |
| 1.3.6.1.4.1.4756.20.442.20.1.326 | ColumneddPort3TxVariableResponseRemoteB | read-only | current | EDD Series card Port3 Detailed Link OAM Statistics: Tx Variable Response |
| 1.3.6.1.4.1.4756.20.442.20.1.327 | ColumneddPort3TxOrgSpecificPDURemoteB | read-only | current | EDD Series card Port3 Detailed Link OAM Statistics: Tx Org Specific PDU's |
| 1.3.6.1.4.1.4756.20.442.20.1.328 | ColumneddPort3TxUnsupportedCodesRemoteB | read-only | current | EDD Series card Port3 Detailed Link OAM Statistics: Tx Unsupported Codes |
| 1.3.6.1.4.1.4756.20.442.20.1.329 | ColumneddPort3TxLinkFaultPDURemoteB | read-only | current | EDD Series card Port3 Detailed Link OAM Statistics: Tx Link Fault PDU's |
| 1.3.6.1.4.1.4756.20.442.20.1.330 | ColumneddPort3TxDyingGaspRemoteB | read-only | current | EDD Series card Port3 Detailed Link OAM Statistics: Tx Dying Gasp |
| 1.3.6.1.4.1.4756.20.442.20.1.331 | ColumneddPort3TxCriticalEventPDURemoteB | read-only | current | EDD Series card Port3 Detailed Link OAM Statistics: Tx Dying Gasp |
| 1.3.6.1.4.1.4756.20.442.20.1.332 | ColumneddPort4RxOAMInfoPDURemoteB | read-only | current | EDD Series card Port4 Detailed Link OAM Statistics: Rx OAM Information PDU's |
| 1.3.6.1.4.1.4756.20.442.20.1.333 | ColumneddPort4RxUniqueErrorEventRemoteB | read-only | current | EDD Series card Port4 Detailed Link OAM Statistics: Rx Unique Error Event Notificatio |
| 1.3.6.1.4.1.4756.20.442.20.1.334 | ColumneddPort4RxDuplicateErrorEventRemoteB | read-only | current | EDD Series card Port4 Detailed Link OAM Statistics: Rx Duplicate Error Event Notification |
| 1.3.6.1.4.1.4756.20.442.20.1.335 | ColumneddPort4RxLoopBackControlRemoteB | read-only | current | EDD Series card Port4 Detailed Link OAM Statistics: Rx Loopback Control |
| 1.3.6.1.4.1.4756.20.442.20.1.336 | ColumneddPort4RxVariableRequestRemoteB | read-only | current | EDD Series card Port4 Detailed Link OAM Statistics: Rx Variable Request |
| 1.3.6.1.4.1.4756.20.442.20.1.337 | ColumneddPort4RxVariableResponseRemoteB | read-only | current | EDD Series card Port4 Detailed Link OAM Statistics: Rx Variable Response |
| 1.3.6.1.4.1.4756.20.442.20.1.338 | ColumneddPort4RxOrgSpecificPDURemoteB | read-only | current | EDD Series card Port4 Detailed Link OAM Statistics: Rx Org Specific PDU's |
| 1.3.6.1.4.1.4756.20.442.20.1.339 | ColumneddPort4RxUnsupportedCodesRemoteB | read-only | current | EDD Series card Port4 Detailed Link OAM Statistics: Rx Unsupported Codes |
| 1.3.6.1.4.1.4756.20.442.20.1.340 | ColumneddPort4RxLinkFaultPDURemoteB | read-only | current | EDD Series card Port4 Detailed Link OAM Statistics: Rx Link Fault PDU's |
| 1.3.6.1.4.1.4756.20.442.20.1.341 | ColumneddPort4RxDyingGaspRemoteB | read-only | current | EDD Series card Port4 Detailed Link OAM Statistics: Rx Dying Gasp |
| 1.3.6.1.4.1.4756.20.442.20.1.342 | ColumneddPort4RxCriticalEventPDURemoteB | read-only | current | EDD Series card Port4 Detailed Link OAM Statistics: Rx Dying Gasp |
| 1.3.6.1.4.1.4756.20.442.20.1.343 | ColumneddPort4TxOAMInfoPDURemoteB | read-only | current | EDD Series card Port4 Detailed Link OAM Statistics: Tx OAM Information PDU's |
| 1.3.6.1.4.1.4756.20.442.20.1.344 | ColumneddPort4TxUniqueErrorEventRemoteB | read-only | current | EDD Series card Port4 Detailed Link OAM Statistics: Tx Unique Error Event Notificatio |
| 1.3.6.1.4.1.4756.20.442.20.1.345 | ColumneddPort4TxDuplicateErrorEventRemoteB | read-only | current | EDD Series card Port4 Detailed Link OAM Statistics: Tx Duplicate Error Event Notification |
| 1.3.6.1.4.1.4756.20.442.20.1.346 | ColumneddPort4TxLoopBackControlRemoteB | read-only | current | EDD Series card Port4 Detailed Link OAM Statistics: Tx Loopback Control |
| 1.3.6.1.4.1.4756.20.442.20.1.347 | ColumneddPort4TxVariableRequestRemoteB | read-only | current | EDD Series card Port4 Detailed Link OAM Statistics: Tx Variable Request |
| 1.3.6.1.4.1.4756.20.442.20.1.348 | ColumneddPort4TxVariableResponseRemoteB | read-only | current | EDD Series card Port4 Detailed Link OAM Statistics: Tx Variable Response |
| 1.3.6.1.4.1.4756.20.442.20.1.349 | ColumneddPort4TxOrgSpecificPDURemoteB | read-only | current | EDD Series card Port4 Detailed Link OAM Statistics: Tx Org Specific PDU's |
| 1.3.6.1.4.1.4756.20.442.20.1.350 | ColumneddPort4TxUnsupportedCodesRemoteB | read-only | current | EDD Series card Port4 Detailed Link OAM Statistics: Tx Unsupported Codes |
| 1.3.6.1.4.1.4756.20.442.20.1.351 | ColumneddPort4TxLinkFaultPDURemoteB | read-only | current | EDD Series card Port4 Detailed Link OAM Statistics: Tx Link Fault PDU's |
| 1.3.6.1.4.1.4756.20.442.20.1.352 | ColumneddPort4TxDyingGaspRemoteB | read-only | current | EDD Series card Port4 Detailed Link OAM Statistics: Tx Dying Gasp |
| 1.3.6.1.4.1.4756.20.442.20.1.353 | ColumneddPort4TxCriticalEventPDURemoteB | read-only | current | EDD Series card Port4 Detailed Link OAM Statistics: Tx Dying Gasp |
| 1.3.6.1.4.1.4756.20.442.20.1.354 | ColumneddPort1PDUPermisionRemoteB | read-only | current | EDD Series card Detailed Link OAM Status for Port 1: PDU Permission |
| 1.3.6.1.4.1.4756.20.442.20.1.355 | ColumneddPort1DiscoveryStateRemoteB | read-only | current | EDD Series card Detailed Link OAM Status for Port 1: Discovery State |
| 1.3.6.1.4.1.4756.20.442.20.1.356 | ColumneddPort1PeerMACAddrRemoteB | read-only | current | EDD Series card Detailed Link OAM Status for Port 1: Discovery State |
| 1.3.6.1.4.1.4756.20.442.20.1.357 | ColumneddPort1LocalModeRemoteB | read-only | current | EDD Series card Detailed Link OAM Status for Port 1: Local: Mode |
| 1.3.6.1.4.1.4756.20.442.20.1.358 | ColumneddPort1LocalUnOperationRemoteB | read-only | current | EDD Series card Detailed Link OAM Status for Port 1: Local: Unidirectional Operation Support |
| 1.3.6.1.4.1.4756.20.442.20.1.359 | ColumneddPort1LocalRemoteLbRemoteB | read-only | current | EDD Series card Detailed Link OAM Status for Port 1: Local: Remote Loopback Support |
| 1.3.6.1.4.1.4756.20.442.20.1.360 | ColumneddPort1LocalLMRemoteB | read-only | current | EDD Series card Detailed Link OAM Status for Port 1: RemoteB: Link Monitoring Support |
| 1.3.6.1.4.1.4756.20.442.20.1.361 | ColumneddPort1LocalMIBRetrievalRemoteB | read-only | current | EDD Series card Detailed Link OAM Status for Port 1: Local: MIB Retrieval Support |
| 1.3.6.1.4.1.4756.20.442.20.1.362 | ColumneddPort1LocalMTUSizeRemoteB | read-only | current | EDD Series card Detailed Link OAM Status for Port 1: Local: MTU Size |
| 1.3.6.1.4.1.4756.20.442.20.1.363 | ColumneddPort1LocalMultiStateRemoteB | read-only | current | EDD Series card Detailed Link OAM Status for Port 1: Local: Multiplexer State |
| 1.3.6.1.4.1.4756.20.442.20.1.364 | ColumneddPort1LocalParserStateRemoteB | read-only | current | EDD Series card Detailed Link OAM Status for Port 1: Local: Multiplexer State |
| 1.3.6.1.4.1.4756.20.442.20.1.365 | ColumneddPort1LocalOUIRemoteB | read-only | current | EDD Series card Detailed Link OAM Status for Port 1: Local: Organizational Unique Identification |
| 1.3.6.1.4.1.4756.20.442.20.1.366 | ColumneddPort1LocalPDURevRemoteB | read-only | current | EDD Series card Detailed Link OAM Status for Port 1: Local: PDU Revision |
| 1.3.6.1.4.1.4756.20.442.20.1.367 | ColumneddPort1PeerModeRemoteB | read-only | current | EDD Series card Detailed Link OAM Status for Port 1: Peer: Mode |
| 1.3.6.1.4.1.4756.20.442.20.1.368 | ColumneddPort1PeerUnOperationRemoteB | read-only | current | EDD Series card Detailed Link OAM Status for Port 1: Peer: Unidirectional Operation Support |
| 1.3.6.1.4.1.4756.20.442.20.1.369 | ColumneddPort1PeerRemoteLbRemoteB | read-only | current | EDD Series card Detailed Link OAM Status for Port 1: Peer: Remote Loopback Support |
| 1.3.6.1.4.1.4756.20.442.20.1.370 | ColumneddPort1PeerLMRemoteB | read-only | current | EDD Series card Detailed Link OAM Status for Port 1: Peer: Link Monitoring Support |
| 1.3.6.1.4.1.4756.20.442.20.1.371 | ColumneddPort1PeerMIBRetrievalRemoteB | read-only | current | EDD Series card Detailed Link OAM Status for Port 1: Peer: MIB Retrieval Support |
| 1.3.6.1.4.1.4756.20.442.20.1.372 | ColumneddPort1PeerMTUSizeRemoteB | read-only | current | EDD Series card Detailed Link OAM Status for Port 1: Peer: MTU Size |
| 1.3.6.1.4.1.4756.20.442.20.1.373 | ColumneddPort1PeerMultiStateRemoteB | read-only | current | EDD Series card Detailed Link OAM Status for Port 1: Peer: Multiplexer State |
| 1.3.6.1.4.1.4756.20.442.20.1.374 | ColumneddPort1PeerParserStateRemoteB | read-only | current | EDD Series card Detailed Link OAM Status for Port 1: Peer: Multiplexer State |
| 1.3.6.1.4.1.4756.20.442.20.1.375 | ColumneddPort1PeerOUIRemoteB | read-only | current | EDD Series card Detailed Link OAM Status for Port 1: Peer: Organizational Unique Identification |
| 1.3.6.1.4.1.4756.20.442.20.1.376 | ColumneddPort1PeerPDURevRemoteB | read-only | current | EDD Series card Detailed Link OAM Status for Port 1: Peer: PDU Revision |
| 1.3.6.1.4.1.4756.20.442.20.1.377 | ColumneddPort2PDUPermisionRemoteB | read-only | current | EDD Series card Detailed Link OAM Status for Port 2: PDU Permission |
| 1.3.6.1.4.1.4756.20.442.20.1.378 | ColumneddPort2DiscoveryStateRemoteB | read-only | current | EDD Series card Detailed Link OAM Status for Port 2: Discovery State |
| 1.3.6.1.4.1.4756.20.442.20.1.379 | ColumneddPort2PeerMACAddrRemoteB | read-only | current | EDD Series card Detailed Link OAM Status for Port 2: Discovery State |
| 1.3.6.1.4.1.4756.20.442.20.1.380 | ColumneddPort2LocalModeRemoteB | read-only | current | EDD Series card Detailed Link OAM Status for Port 2: Local: Mode |
| 1.3.6.1.4.1.4756.20.442.20.1.381 | ColumneddPort2LocalUnOperationRemoteB | read-only | current | EDD Series card Detailed Link OAM Status for Port 2: Local: Unidirectional Operation Support |
| 1.3.6.1.4.1.4756.20.442.20.1.382 | ColumneddPort2LocalRemoteLbRemoteB | read-only | current | EDD Series card Detailed Link OAM Status for Port 2: Local: Remote Loopback Support |
| 1.3.6.1.4.1.4756.20.442.20.1.383 | ColumneddPort2LocalLMRemoteB | read-only | current | EDD Series card Detailed Link OAM Status for Port 2: Local: Link Monitoring Support |
| 1.3.6.1.4.1.4756.20.442.20.1.384 | ColumneddPort2LocalMIBRetrievalRemoteB | read-only | current | EDD Series card Detailed Link OAM Status for Port 2: Local: MIB Retrieval Support |
| 1.3.6.1.4.1.4756.20.442.20.1.385 | ColumneddPort2LocalMTUSizeRemoteB | read-only | current | EDD Series card Detailed Link OAM Status for Port 2: Local: MTU Size |
| 1.3.6.1.4.1.4756.20.442.20.1.386 | ColumneddPort2LocalMultiStateRemoteB | read-only | current | EDD Series card Detailed Link OAM Status for Port 2: Local: Multiplexer State |
| 1.3.6.1.4.1.4756.20.442.20.1.387 | ColumneddPort2LocalParserStateRemoteB | read-only | current | EDD Series card Detailed Link OAM Status for Port 2: Local: Multiplexer State |
| 1.3.6.1.4.1.4756.20.442.20.1.388 | ColumneddPort2LocalOUIRemoteB | read-only | current | EDD Series card Detailed Link OAM Status for Port 2: Local: Organizational Unique Identification |
| 1.3.6.1.4.1.4756.20.442.20.1.389 | ColumneddPort2LocalPDURevRemoteB | read-only | current | EDD Series card Detailed Link OAM Status for Port 2: Local: PDU Revision |
| 1.3.6.1.4.1.4756.20.442.20.1.390 | ColumneddPort2PeerModeRemoteB | read-only | current | EDD Series card Detailed Link OAM Status for Port 2: Peer: Mode |
| 1.3.6.1.4.1.4756.20.442.20.1.391 | ColumneddPort2PeerUnOperationRemoteB | read-only | current | EDD Series card Detailed Link OAM Status for Port 2: Peer: Unidirectional Operation Support |
| 1.3.6.1.4.1.4756.20.442.20.1.392 | ColumneddPort2PeerRemoteLbRemoteB | read-only | current | EDD Series card Detailed Link OAM Status for Port 2: Peer: Remote Loopback Support |
| 1.3.6.1.4.1.4756.20.442.20.1.393 | ColumneddPort2PeerLMRemoteB | read-only | current | EDD Series card Detailed Link OAM Status for Port 2: Peer: Link Monitoring Support |
| 1.3.6.1.4.1.4756.20.442.20.1.394 | ColumneddPort2PeerMIBRetrievalRemoteB | read-only | current | EDD Series card Detailed Link OAM Status for Port 2: Peer: MIB Retrieval Support |
| 1.3.6.1.4.1.4756.20.442.20.1.395 | ColumneddPort2PeerMTUSizeRemoteB | read-only | current | EDD Series card Detailed Link OAM Status for Port 2: Peer: MTU Size |
| 1.3.6.1.4.1.4756.20.442.20.1.396 | ColumneddPort2PeerMultiStateRemoteB | read-only | current | EDD Series card Detailed Link OAM Status for Port 2: Peer: Multiplexer State |
| 1.3.6.1.4.1.4756.20.442.20.1.397 | ColumneddPort2PeerParserStateRemoteB | read-only | current | EDD Series card Detailed Link OAM Status for Port 2: Peer: Multiplexer State |
| 1.3.6.1.4.1.4756.20.442.20.1.398 | ColumneddPort2PeerOUIRemoteB | read-only | current | EDD Series card Detailed Link OAM Status for Port 2: Peer: Organizational Unique Identification |
| 1.3.6.1.4.1.4756.20.442.20.1.399 | ColumneddPort2PeerPDURevRemoteB | read-only | current | EDD Series card Detailed Link OAM Status for Port 2: Peer: PDU Revision |
| 1.3.6.1.4.1.4756.20.442.20.1.400 | ColumneddPort3PDUPermisionRemoteB | read-only | current | EDD Series card Detailed Link OAM Status for Port 3: PDU Permission |
| 1.3.6.1.4.1.4756.20.442.20.1.401 | ColumneddPort3DiscoveryStateRemoteB | read-only | current | EDD Series card Detailed Link OAM Status for Port 3: Discovery State |
| 1.3.6.1.4.1.4756.20.442.20.1.402 | ColumneddPort3PeerMACAddrRemoteB | read-only | current | EDD Series card Detailed Link OAM Status for Port 3: Discovery State |
| 1.3.6.1.4.1.4756.20.442.20.1.403 | ColumneddPort3LocalModeRemoteB | read-only | current | EDD Series card Detailed Link OAM Status for Port 3: Local: Mode |
| 1.3.6.1.4.1.4756.20.442.20.1.404 | ColumneddPort3LocalUnOperationRemoteB | read-only | current | EDD Series card Detailed Link OAM Status for Port 3: Local: Unidirectional Operation Support |
| 1.3.6.1.4.1.4756.20.442.20.1.405 | ColumneddPort3LocalRemoteLbRemoteB | read-only | current | EDD Series card Detailed Link OAM Status for Port 3: Local: Remote Loopback Support |
| 1.3.6.1.4.1.4756.20.442.20.1.406 | ColumneddPort3LocalLMRemoteB | read-only | current | EDD Series card Detailed Link OAM Status for Port 3: Local: Link Monitoring Support |
| 1.3.6.1.4.1.4756.20.442.20.1.407 | ColumneddPort3LocalMIBRetrievalRemoteB | read-only | current | EDD Series card Detailed Link OAM Status for Port 3: Local: MIB Retrieval Support |
| 1.3.6.1.4.1.4756.20.442.20.1.408 | ColumneddPort3LocalMTUSizeRemoteB | read-only | current | EDD Series card Detailed Link OAM Status for Port 3: Local: MTU Size |
| 1.3.6.1.4.1.4756.20.442.20.1.409 | ColumneddPort3LocalMultiStateRemoteB | read-only | current | EDD Series card Detailed Link OAM Status for Port 3: Local: Multiplexer State |
| 1.3.6.1.4.1.4756.20.442.20.1.410 | ColumneddPort3LocalParserStateRemoteB | read-only | current | EDD Series card Detailed Link OAM Status for Port 3: Local: Multiplexer State |
| 1.3.6.1.4.1.4756.20.442.20.1.411 | ColumneddPort3LocalOUIRemoteB | read-only | current | EDD Series card Detailed Link OAM Status for Port 3: Local: Organizational Unique Identification |
| 1.3.6.1.4.1.4756.20.442.20.1.412 | ColumneddPort3LocalPDURevRemoteB | read-only | current | EDD Series card Detailed Link OAM Status for Port 3: Local: PDU Revision |
| 1.3.6.1.4.1.4756.20.442.20.1.413 | ColumneddPort3PeerModeRemoteB | read-only | current | EDD Series card Detailed Link OAM Status for Port 3: Peer: Mode |
| 1.3.6.1.4.1.4756.20.442.20.1.414 | ColumneddPort3PeerUnOperationRemoteB | read-only | current | EDD Series card Detailed Link OAM Status for Port 3: Peer: Unidirectional Operation Support |
| 1.3.6.1.4.1.4756.20.442.20.1.415 | ColumneddPort3PeerRemoteLbRemoteB | read-only | current | EDD Series card Detailed Link OAM Status for Port 3: Peer: Remote Loopback Support |
| 1.3.6.1.4.1.4756.20.442.20.1.416 | ColumneddPort3PeerLMRemoteB | read-only | current | EDD Series card Detailed Link OAM Status for Port 3: Peer: Link Monitoring Support |
| 1.3.6.1.4.1.4756.20.442.20.1.417 | ColumneddPort3PeerMIBRetrievalRemoteB | read-only | current | EDD Series card Detailed Link OAM Status for Port 3: Peer: MIB Retrieval Support |
| 1.3.6.1.4.1.4756.20.442.20.1.418 | ColumneddPort3PeerMTUSizeRemoteB | read-only | current | EDD Series card Detailed Link OAM Status for Port 3: Peer: MTU Size |
| 1.3.6.1.4.1.4756.20.442.20.1.419 | ColumneddPort3PeerMultiStateRemoteB | read-only | current | EDD Series card Detailed Link OAM Status for Port 3: Peer: Multiplexer State |
| 1.3.6.1.4.1.4756.20.442.20.1.420 | ColumneddPort3PeerParserStateRemoteB | read-only | current | EDD Series card Detailed Link OAM Status for Port 3: Peer: Multiplexer State |
| 1.3.6.1.4.1.4756.20.442.20.1.421 | ColumneddPort3PeerOUIRemoteB | read-only | current | EDD Series card Detailed Link OAM Status for Port 3: Peer: Organizational Unique Identification |
| 1.3.6.1.4.1.4756.20.442.20.1.422 | ColumneddPort3PeerPDURevRemoteB | read-only | current | EDD Series card Detailed Link OAM Status for Port 3: Peer: PDU Revision |
| 1.3.6.1.4.1.4756.20.442.20.1.423 | ColumneddPort4PDUPermisionRemoteB | read-only | current | EDD Series card Detailed Link OAM Status for Port 4: PDU Permission |
| 1.3.6.1.4.1.4756.20.442.20.1.424 | ColumneddPort4DiscoveryStateRemoteB | read-only | current | EDD Series card Detailed Link OAM Status for Port 4: Discovery State |
| 1.3.6.1.4.1.4756.20.442.20.1.425 | ColumneddPort4PeerMACAddrRemoteB | read-only | current | EDD Series card Detailed Link OAM Status for Port 4: Discovery State |
| 1.3.6.1.4.1.4756.20.442.20.1.426 | ColumneddPort4LocalModeRemoteB | read-only | current | EDD Series card Detailed Link OAM Status for Port 4: Local: Mode |
| 1.3.6.1.4.1.4756.20.442.20.1.427 | ColumneddPort4LocalUnOperationRemoteB | read-only | current | EDD Series card Detailed Link OAM Status for Port 4: Local: Unidirectional Operation Support |
| 1.3.6.1.4.1.4756.20.442.20.1.428 | ColumneddPort4LocalRemoteLbRemoteB | read-only | current | EDD Series card Detailed Link OAM Status for Port 4: Local: Remote Loopback Support |
| 1.3.6.1.4.1.4756.20.442.20.1.429 | ColumneddPort4LocalLMRemoteB | read-only | current | EDD Series card Detailed Link OAM Status for Port 4: Local: Link Monitoring Support |
| 1.3.6.1.4.1.4756.20.442.20.1.430 | ColumneddPort4LocalMIBRetrievalRemoteB | read-only | current | EDD Series card Detailed Link OAM Status for Port 4: Local: MIB Retrieval Support |
| 1.3.6.1.4.1.4756.20.442.20.1.431 | ColumneddPort4LocalMTUSizeRemoteB | read-only | current | EDD Series card Detailed Link OAM Status for Port 4: Local: MTU Size |
| 1.3.6.1.4.1.4756.20.442.20.1.432 | ColumneddPort4LocalMultiStateRemoteB | read-only | current | EDD Series card Detailed Link OAM Status for Port 4: Local: Multiplexer State |
| 1.3.6.1.4.1.4756.20.442.20.1.433 | ColumneddPort4LocalParserStateRemoteB | read-only | current | EDD Series card Detailed Link OAM Status for Port 4: Local: Multiplexer State |
| 1.3.6.1.4.1.4756.20.442.20.1.434 | ColumneddPort4LocalOUIRemoteB | read-only | current | EDD Series card Detailed Link OAM Status for Port 4: Local: Organizational Unique Identification |
| 1.3.6.1.4.1.4756.20.442.20.1.435 | ColumneddPort4LocalPDURevRemoteB | read-only | current | EDD Series card Detailed Link OAM Status for Port 4: Local: PDU Revision |
| 1.3.6.1.4.1.4756.20.442.20.1.436 | ColumneddPort4PeerModeRemoteB | read-only | current | EDD Series card Detailed Link OAM Status for Port 4: Peer: Mode |
| 1.3.6.1.4.1.4756.20.442.20.1.437 | ColumneddPort4PeerUnOperationRemoteB | read-only | current | EDD Series card Detailed Link OAM Status for Port 4: Peer: Unidirectional Operation Support |
| 1.3.6.1.4.1.4756.20.442.20.1.438 | ColumneddPort4PeerRemoteLbRemoteB | read-only | current | EDD Series card Detailed Link OAM Status for Port 4: Peer: Remote Loopback Support |
| 1.3.6.1.4.1.4756.20.442.20.1.439 | ColumneddPort4PeerLMRemoteB | read-only | current | EDD Series card Detailed Link OAM Status for Port 4: Peer: Link Monitoring Support |
| 1.3.6.1.4.1.4756.20.442.20.1.440 | ColumneddPort4PeerMIBRetrievalRemoteB | read-only | current | EDD Series card Detailed Link OAM Status for Port 4: Peer: MIB Retrieval Support |
| 1.3.6.1.4.1.4756.20.442.20.1.441 | ColumneddPort4PeerMTUSizeRemoteB | read-only | current | EDD Series card Detailed Link OAM Status for Port 4: Peer: MTU Size |
| 1.3.6.1.4.1.4756.20.442.20.1.442 | ColumneddPort4PeerMultiStateRemoteB | read-only | current | EDD Series card Detailed Link OAM Status for Port 4: Peer: Multiplexer State |
| 1.3.6.1.4.1.4756.20.442.20.1.443 | ColumneddPort4PeerParserStateRemoteB | read-only | current | EDD Series card Detailed Link OAM Status for Port 4: Peer: Multiplexer State |
| 1.3.6.1.4.1.4756.20.442.20.1.444 | ColumneddPort4PeerOUIRemoteB | read-only | current | EDD Series card Detailed Link OAM Status for Port 4: Peer: Organizational Unique Identification |
| 1.3.6.1.4.1.4756.20.442.20.1.445 | ColumneddPort4PeerPDURevRemoteB | read-only | current | EDD Series card Detailed Link OAM Status for Port 4: Peer: PDU Revision |
| 1.3.6.1.4.1.4756.20.442.20.1.446 | ColumneddCLEAROAMCOUNTERRemoteB | read-write | current | EDD Series card Clear OAM Counter: 0: Off 1: Action |
| 1.3.6.1.4.1.4756.20.442.20.1.447 | ColumneddLoopProtectionEnableRemoteB | read-write | current | EDD Series card Loop Protection Configuration: General Settings - Enable Loop Protection 0: Disable 1: Enable |
| 1.3.6.1.4.1.4756.20.442.20.1.448 | ColumneddLoopProtectionTxTimeRemoteB | read-write | current | EDD Series card Loop Protection Configuration: General Settings - Transmission Time |
| 1.3.6.1.4.1.4756.20.442.20.1.449 | ColumneddLoopProtectionShutdownTimeRemoteB | read-write | current | EDD Series card Loop Protection Configuration: General Settings - Shutdown Time |
| 1.3.6.1.4.1.4756.20.442.20.1.450 | ColumneddLoopProtectionPort1EnabledRemoteB | read-write | current | EDD Series card Loop Protection Configuration for Port 1: Port Configuration - Enable 0: Disable 1: Enable |
| 1.3.6.1.4.1.4756.20.442.20.1.451 | ColumneddLoopProtectionPort1ActionRemoteB | read-write | current | EDD Series card Loop Protection Configuration for Port 1: Port Configuration - Action 0: Shutdown Port 1: Shutdown Port And Log 2: Log Only |
| 1.3.6.1.4.1.4756.20.442.20.1.452 | ColumneddLoopProtectionPort1TxModeRemoteB | read-write | current | EDD Series card Loop Protection Configuration for Port 1: Port Configuration - Tx Mode 0: Disable 1: Enable |
| 1.3.6.1.4.1.4756.20.442.20.1.453 | ColumneddLoopProtectionPort2EnabledRemoteB | read-write | current | EDD Series card Loop Protection Configuration for Port 2: Port Configuration - Enable 0: Disable 1: Enable |
| 1.3.6.1.4.1.4756.20.442.20.1.454 | ColumneddLoopProtectionPort2ActionRemoteB | read-write | current | EDD Series card Loop Protection Configuration for Port 2: Port Configuration - Action 0: Shutdown Port 1: Shutdown Port And Log 2: Log Only |
| 1.3.6.1.4.1.4756.20.442.20.1.455 | ColumneddLoopProtectionPort2TxModeRemoteB | read-write | current | EDD Series card Loop Protection Configuration for Port 2: Port Configuration - Tx Mode 0: Disable 1: Enable |
| 1.3.6.1.4.1.4756.20.442.20.1.456 | ColumneddLoopProtectionPort3EnabledRemoteB | read-write | current | EDD Series card Loop Protection Configuration for Port 3: Port Configuration - Enable 0: Disable 1: Enable |
| 1.3.6.1.4.1.4756.20.442.20.1.457 | ColumneddLoopProtectionPort3ActionRemoteB | read-write | current | EDD Series card Loop Protection Configuration for Port 3: Port Configuration - Action 0: Shutdown Port 1: Shutdown Port And Log 2: Log Only |
| 1.3.6.1.4.1.4756.20.442.20.1.458 | ColumneddLoopProtectionPort3TxModeRemoteB | read-write | current | EDD Series card Loop Protection Configuration for Port 3: Port Configuration - Tx Mode 0: Disable 1: Enable |
| 1.3.6.1.4.1.4756.20.442.20.1.459 | ColumneddLoopProtectionPort4EnabledRemoteB | read-write | current | EDD Series card Loop Protection Configuration for Port 4: Port Configuration - Enable 0: Disable 1: Enable |
| 1.3.6.1.4.1.4756.20.442.20.1.460 | ColumneddLoopProtectionPort4ActionRemoteB | read-write | current | EDD Series card Loop Protection Configuration for Port 4: Port Configuration - Action 0: Shutdown Port 1: Shutdown Port And Log 2: Log Only |
| 1.3.6.1.4.1.4756.20.442.20.1.461 | ColumneddLoopProtectionPort4TxModeRemoteB | read-write | current | EDD Series card Loop Protection Configuration for Port 41: Port Configuration - Tx Mode 0: Disable 1: Enable |
| 1.3.6.1.4.1.4756.20.442.20.1.462 | ColumneddLoopProtectionPort1ActionStsRemoteB | read-only | current | EDD Series card Loop Protection Status for Port 1: Action |
| 1.3.6.1.4.1.4756.20.442.20.1.463 | ColumneddLoopProtectionPort1TransStsRemoteB | read-only | current | EDD Series card Loop Protection Status for Port 1: Transmit |
| 1.3.6.1.4.1.4756.20.442.20.1.464 | ColumneddLoopProtectionPort1LoopsStsRemoteB | read-only | current | EDD Series card Loop Protection Status for Port 1: Loops |
| 1.3.6.1.4.1.4756.20.442.20.1.465 | ColumneddLoopProtectionPort1StatusRemoteB | read-only | current | EDD Series card Loop Protection Status for Port 1: Status |
| 1.3.6.1.4.1.4756.20.442.20.1.466 | ColumneddLoopProtectionPort1LoopStsRemoteB | read-only | current | EDD Series card Loop Protection Status for Port 1: Loop |
| 1.3.6.1.4.1.4756.20.442.20.1.467 | ColumneddLoopProtectionPort1TimeOfLastLoopRemoteB | read-only | current | EDD Series card Loop Protection Status for Port 1: Time of Last Loop |
| 1.3.6.1.4.1.4756.20.442.20.1.468 | ColumneddLoopProtectionPort2ActionStsRemoteB | read-only | current | EDD Series card Loop Protection Status for Port 2: Action |
| 1.3.6.1.4.1.4756.20.442.20.1.469 | ColumneddLoopProtectionPort2TransStsRemoteB | read-only | current | EDD Series card Loop Protection Status for Port 2: Transmit |
| 1.3.6.1.4.1.4756.20.442.20.1.470 | ColumneddLoopProtectionPort2LoopsStsRemoteB | read-only | current | EDD Series card Loop Protection Status for Port 2: Loops |
| 1.3.6.1.4.1.4756.20.442.20.1.471 | ColumneddLoopProtectionPort2StatusRemoteB | read-only | current | EDD Series card Loop Protection Status for Port 2: Status |
| 1.3.6.1.4.1.4756.20.442.20.1.472 | ColumneddLoopProtectionPort2LoopStsRemoteB | read-only | current | EDD Series card Loop Protection Status for Port 2: Loop |
| 1.3.6.1.4.1.4756.20.442.20.1.473 | ColumneddLoopProtectionPort2TimeOfLastLoopRemoteB | read-only | current | EDD Series card Loop Protection Status for Port 2: Time of Last Loop |
| 1.3.6.1.4.1.4756.20.442.20.1.474 | ColumneddLoopProtectionPort3ActionStsRemoteB | read-only | current | EDD Series card Loop Protection Status for Port 3: Action |
| 1.3.6.1.4.1.4756.20.442.20.1.475 | ColumneddLoopProtectionPort3TransStsRemoteB | read-only | current | EDD Series card Loop Protection Status for Port 3: Transmit |
| 1.3.6.1.4.1.4756.20.442.20.1.476 | ColumneddLoopProtectionPort3LoopsStsRemoteB | read-only | current | EDD Series card Loop Protection Status for Port 3: Loops |
| 1.3.6.1.4.1.4756.20.442.20.1.477 | ColumneddLoopProtectionPort3StatusRemoteB | read-only | current | EDD Series card Loop Protection Status for Port 3: Status |
| 1.3.6.1.4.1.4756.20.442.20.1.478 | ColumneddLoopProtectionPort3LoopStsRemoteB | read-only | current | EDD Series card Loop Protection Status for Port 3: Loop |
| 1.3.6.1.4.1.4756.20.442.20.1.479 | ColumneddLoopProtectionPort3TimeOfLastLoopRemoteB | read-only | current | EDD Series card Loop Protection Status for Port 3: Time of Last Loop |
| 1.3.6.1.4.1.4756.20.442.20.1.480 | ColumneddLoopProtectionPort4ActionStsRemoteB | read-only | current | EDD Series card Loop Protection Status for Port 4: Action |
| 1.3.6.1.4.1.4756.20.442.20.1.481 | ColumneddLoopProtectionPort4TransStsRemoteB | read-only | current | EDD Series card Loop Protection Status for Port 4: Transmit |
| 1.3.6.1.4.1.4756.20.442.20.1.482 | ColumneddLoopProtectionPort4LoopsStsRemoteB | read-only | current | EDD Series card Loop Protection Status for Port 4: Loops |
| 1.3.6.1.4.1.4756.20.442.20.1.483 | ColumneddLoopProtectionPort4StatusRemoteB | read-only | current | EDD Series card Loop Protection Status for Port 4: Status |
| 1.3.6.1.4.1.4756.20.442.20.1.484 | ColumneddLoopProtectionPort4LoopStsRemoteB | read-only | current | EDD Series card Loop Protection Status for Port 4: Loop |
| 1.3.6.1.4.1.4756.20.442.20.1.485 | ColumneddLoopProtectionPort4TimeOfLastLoopRemoteB | read-only | current | EDD Series card Loop Protection Status for Port 4: Time of Last Loop |
| 1.3.6.1.4.1.4756.20.442.20.1.486 | ColumneddSTPProtocolVersionRemoteB | read-write | current | EDD Series card STP Bridge Configuration: Basic Settings - Protocol Version 0: STP 1: RSTP 2: MSTP |
| 1.3.6.1.4.1.4756.20.442.20.1.487 | ColumneddSTPBridgePriorityRemoteB | read-write | current | EDD Series card STP Bridge Configuration: Basic Settings - Bridge Priority 0: 0 1: 4096 2: 8192 3: 12288 4: 16384 5: 20480 6: 24576 7: 28672 8: 32768 9: 36864 … |
| 1.3.6.1.4.1.4756.20.442.20.1.488 | ColumneddSTPForwardDelayRemoteB | read-write | current | EDD Series card STP Bridge Configuration: Basic Settings - Forward Delay |
| 1.3.6.1.4.1.4756.20.442.20.1.489 | ColumneddSTPMaxAgeRemoteB | read-write | current | EDD Series card STP Bridge Configuration: Basic Settings - Max Age |
| 1.3.6.1.4.1.4756.20.442.20.1.490 | ColumneddSTPMaximumHopCountRemoteB | read-write | current | EDD Series card STP Bridge Configuration: Basic Settings - Maximum Hop Count |
| 1.3.6.1.4.1.4756.20.442.20.1.491 | ColumneddSTPTransmitHoldCountRemoteB | read-write | current | EDD Series card STP Bridge Configuration: Basic Settings - Transmit Hold Count |
| 1.3.6.1.4.1.4756.20.442.20.1.492 | ColumneddSTPEdgePortBPDUFilteringRemoteB | read-write | current | EDD Series card STP Bridge Configuration: Advanced Settings - Edge Port BPDU Filtering 0: Off 1: On |
| 1.3.6.1.4.1.4756.20.442.20.1.493 | ColumneddSTPEdgePortBPDUGuardRemoteB | read-write | current | EDD Series card STP Bridge Configuration: Advanced Settings - Edge Port BPDU Guard 0: Off 1: On |
| 1.3.6.1.4.1.4756.20.442.20.1.494 | ColumneddSTPPortErrorRecoveryTimeoutRemoteB | read-write | current | EDD Series card STP Bridge Configuration: Advanced Settings - Port Error Recovery Timeout 0: Off 1: On |
| 1.3.6.1.4.1.4756.20.442.20.1.495 | ColumneddMSTIConfigurationNameRemoteB | read-write | current | EDD Series card MSTI Configuration: Configuration Identification - Configuration Name |
| 1.3.6.1.4.1.4756.20.442.20.1.496 | ColumneddMSTIConfigurationRevisionRemoteB | read-write | current | EDD Series card MSTI Configuration: Configuration Identification - Configuration Revision |
| 1.3.6.1.4.1.4756.20.442.20.1.497 | ColumneddMSTI1VLANsMappingRemoteB | read-write | current | EDD Series card MSTI Configuration: MSTI Mapping - MSTI 1 |
| 1.3.6.1.4.1.4756.20.442.20.1.498 | ColumneddMSTI2VLANsMappingRemoteB | read-write | current | EDD Series card MSTI Configuration: MSTI Mapping - MSTI 2 |
| 1.3.6.1.4.1.4756.20.442.20.1.499 | ColumneddMSTI3VLANsMappingRemoteB | read-write | current | EDD Series card MSTI Configuration: MSTI Mapping - MSTI 3 |
| 1.3.6.1.4.1.4756.20.442.20.1.500 | ColumneddMSTI4VLANsMappingRemoteB | read-write | current | EDD Series card MSTI Configuration: MSTI Mapping - MSTI 4 |
| 1.3.6.1.4.1.4756.20.442.20.1.501 | ColumneddMSTI5VLANsMappingRemoteB | read-write | current | EDD Series card MSTI Configuration: MSTI Mapping - MSTI 5 |
| 1.3.6.1.4.1.4756.20.442.20.1.502 | ColumneddMSTI6VLANsMappingRemoteB | read-write | current | EDD Series card MSTI Configuration: MSTI Mapping - MSTI 6 |
| 1.3.6.1.4.1.4756.20.442.20.1.503 | ColumneddMSTI7VLANsMappingRemoteB | read-write | current | EDD Series card MSTI Configuration: MSTI Mapping - MSTI 7 |
| 1.3.6.1.4.1.4756.20.442.20.1.504 | ColumneddCISTAggregatedSTPEnabledRemoteB | read-write | current | EDD Series card STP CIST Port Configuration: CIST Aggregated Port Configuration - STP Enabled |
| 1.3.6.1.4.1.4756.20.442.20.1.505 | ColumneddCISTAggregatedPathCostRemoteB | read-write | current | EDD Series card STP CIST Port Configuration: CIST Aggregated Port Configuration - Path Cost Valid values are in the range 0 to 200000000. Setting 0 means Auto … |
| 1.3.6.1.4.1.4756.20.442.20.1.506 | ColumneddCISTAggregatedPriorityRemoteB | read-write | current | EDD Series card STP CIST Port Configuration: CIST Aggregated Port Configuration - Priority |
| 1.3.6.1.4.1.4756.20.442.20.1.507 | ColumneddCISTAggregatedAdminEdgeRemoteB | read-write | current | EDD Series card STP CIST Port Configuration: CIST Aggregated Port Configuration - STP Enabled 0: Non-edge 1: Edge |
| 1.3.6.1.4.1.4756.20.442.20.1.508 | ColumneddCISTAggregatedAutoEdgeRemoteB | read-write | current | EDD Series card STP CIST Port Configuration: CIST Aggregated Port Configuration - Auto Edge 0: Non-edge 1: Edge |
| 1.3.6.1.4.1.4756.20.442.20.1.509 | ColumneddCISTAggregatedRestrictedRoleRemoteB | read-write | current | EDD Series card STP CIST Port Configuration: CIST Aggregated Port Configuration - Restricted Role 0: Non-edge 1: Edge |
| 1.3.6.1.4.1.4756.20.442.20.1.510 | ColumneddCISTAggregatedRestrictedTCNRemoteB | read-write | current | EDD Series card STP CIST Port Configuration: CIST Aggregated Port Configuration - Restricted TCN 0: Non-edge 1: Edge |
| 1.3.6.1.4.1.4756.20.442.20.1.511 | ColumneddCISTAggregatedBPDUGuardRemoteB | read-write | current | EDD Series card STP CIST Port Configuration: CIST Aggregated Port Configuration - BPDU Guard 0: Non-edge 1: Edge |
| 1.3.6.1.4.1.4756.20.442.20.1.512 | ColumneddCISTAggregatedPointToPointRemoteB | read-write | current | EDD Series card STP CIST Port Configuration: CIST Aggregated Port Configuration - Point-to-point 0: Forced True 1: Forced False 2: Auto |
| 1.3.6.1.4.1.4756.20.442.20.1.513 | ColumneddCISTPort1STPEnabledRemoteB | read-write | current | EDD Series card STP CIST Port Configuration: CIST Normal Port1 Configuration - STP Enabled |
| 1.3.6.1.4.1.4756.20.442.20.1.514 | ColumneddCISTPort1PathCostRemoteB | read-write | current | EDD Series card STP CIST Port Configuration: CIST Normal Port1 Configuration - Path Cost Valid values are in the range 0 to 200000000. Setting 0 means Auto pat… |
| 1.3.6.1.4.1.4756.20.442.20.1.515 | ColumneddCISTPort1PriorityRemoteB | read-write | current | EDD Series card STP CIST Port Configuration: CIST Normal Port1 Configuration - Priority |
| 1.3.6.1.4.1.4756.20.442.20.1.516 | ColumneddCISTPort1AdminEdgeRemoteB | read-write | current | EDD Series card STP CIST Port Configuration: CIST Normal Port1 Configuration - STP Enabled 0: Non-edge 1: Edge |
| 1.3.6.1.4.1.4756.20.442.20.1.517 | ColumneddCISTPort1AutoEdgeRemoteB | read-write | current | EDD Series card STP CIST Port Configuration: CIST Normal Port1 Configuration - Auto Edge 0: Non-edge 1: Edge |
| 1.3.6.1.4.1.4756.20.442.20.1.518 | ColumneddCISTPort1RestrictedRoleRemoteB | read-write | current | EDD Series card STP CIST Port Configuration: CIST Normal Port1 Configuration - Restricted Role 0: Non-edge 1: Edge |
| 1.3.6.1.4.1.4756.20.442.20.1.519 | ColumneddCISTPort1RestrictedTCNRemoteB | read-write | current | EDD Series card STP CIST Port Configuration: CIST Normal Port1 Configuration - Restricted TCN 0: Non-edge 1: Edge |
| 1.3.6.1.4.1.4756.20.442.20.1.520 | ColumneddCISTPort1BPDUGuardRemoteB | read-write | current | EDD Series card STP CIST Port Configuration: CIST Normal Port1 Configuration - BPDU Guard 0: Non-edge 1: Edge |
| 1.3.6.1.4.1.4756.20.442.20.1.521 | ColumneddCISTPort1PointToPointRemoteB | read-write | current | EDD Series card STP CIST Port Configuration: CIST Normal Port1 Configuration - Point-to-point 0: Forced True 1: Forced False 2: Auto |
| 1.3.6.1.4.1.4756.20.442.20.1.522 | ColumneddCISTPort2STPEnabledRemoteB | read-write | current | EDD Series card STP CIST Port Configuration: CIST Normal Port2 Configuration - STP Enabled |
| 1.3.6.1.4.1.4756.20.442.20.1.523 | ColumneddCISTPort2PathCostRemoteB | read-write | current | EDD Series card STP CIST Port Configuration: CIST Normal Port2 Configuration - Path Cost Valid values are in the range 0 to 200000000. Setting 0 means Auto pat… |
| 1.3.6.1.4.1.4756.20.442.20.1.524 | ColumneddCISTPort2PriorityRemoteB | read-write | current | EDD Series card STP CIST Port Configuration: CIST Normal Port2 Configuration - Priority |
| 1.3.6.1.4.1.4756.20.442.20.1.525 | ColumneddCISTPort2AdminEdgeRemoteB | read-write | current | EDD Series card STP CIST Port Configuration: CIST Normal Port2 Configuration - STP Enabled 0: Non-edge 1: Edge |
| 1.3.6.1.4.1.4756.20.442.20.1.526 | ColumneddCISTPort2AutoEdgeRemoteB | read-write | current | EDD Series card STP CIST Port Configuration: CIST Normal Port2 Configuration - Auto Edge 0: Non-edge 1: Edge |
| 1.3.6.1.4.1.4756.20.442.20.1.527 | ColumneddCISTPort2RestrictedRoleRemoteB | read-write | current | EDD Series card STP CIST Port Configuration: CIST Normal Port2 Configuration - Restricted Role 0: Non-edge 1: Edge |
| 1.3.6.1.4.1.4756.20.442.20.1.528 | ColumneddCISTPort2RestrictedTCNRemoteB | read-write | current | EDD Series card STP CIST Port Configuration: CIST Normal Port2 Configuration - Restricted TCN 0: Non-edge 1: Edge |
| 1.3.6.1.4.1.4756.20.442.20.1.529 | ColumneddCISTPort2BPDUGuardRemoteB | read-write | current | EDD Series card STP CIST Port Configuration: CIST Normal Port2 Configuration - BPDU Guard 0: Non-edge 1: Edge |
| 1.3.6.1.4.1.4756.20.442.20.1.530 | ColumneddCISTPort2PointToPointRemoteB | read-write | current | EDD Series card STP CIST Port Configuration: CIST Normal Port2 Configuration - Point-to-point 0: Forced True 1: Forced False 2: Auto |
| 1.3.6.1.4.1.4756.20.442.20.1.531 | ColumneddCISTPort3STPEnabledRemoteB | read-write | current | EDD Series card STP CIST Port Configuration: CIST Normal Port3 Configuration - STP Enabled |
| 1.3.6.1.4.1.4756.20.442.20.1.532 | ColumneddCISTPort3PathCostRemoteB | read-write | current | EDD Series card STP CIST Port Configuration: CIST Normal Port3 Configuration - Path Cost Valid values are in the range 0 to 200000000. Setting 0 means Auto pat… |
| 1.3.6.1.4.1.4756.20.442.20.1.533 | ColumneddCISTPort3PriorityRemoteB | read-write | current | EDD Series card STP CIST Port Configuration: CIST Normal Port3 Configuration - Priority |
| 1.3.6.1.4.1.4756.20.442.20.1.534 | ColumneddCISTPort3AdminEdgeRemoteB | read-write | current | EDD Series card STP CIST Port Configuration: CIST Normal Port3 Configuration - STP Enabled 0: Non-edge 1: Edge |
| 1.3.6.1.4.1.4756.20.442.20.1.535 | ColumneddCISTPort3AutoEdgeRemoteB | read-write | current | EDD Series card STP CIST Port Configuration: CIST Normal Port3 Configuration - Auto Edge 0: Non-edge 1: Edge |
| 1.3.6.1.4.1.4756.20.442.20.1.536 | ColumneddCISTPort3RestrictedRoleRemoteB | read-write | current | EDD Series card STP CIST Port Configuration: CIST Normal Port3 Configuration - Restricted Role 0: Non-edge 1: Edge |
| 1.3.6.1.4.1.4756.20.442.20.1.537 | ColumneddCISTPort3RestrictedTCNRemoteB | read-write | current | EDD Series card STP CIST Port Configuration: CIST Normal Port3 Configuration - Restricted TCN 0: Non-edge 1: Edge |
| 1.3.6.1.4.1.4756.20.442.20.1.538 | ColumneddCISTPort3BPDUGuardRemoteB | read-write | current | EDD Series card STP CIST Port Configuration: CIST Normal Port3 Configuration - BPDU Guard 0: Non-edge 1: Edge |
| 1.3.6.1.4.1.4756.20.442.20.1.539 | ColumneddCISTPort3PointToPointRemoteB | read-write | current | EDD Series card STP CIST Port Configuration: CIST Normal Port3 Configuration - Point-to-point 0: Forced True 1: Forced False 2: Auto |
| 1.3.6.1.4.1.4756.20.442.20.1.540 | ColumneddCISTPort4STPEnabledRemoteB | read-write | current | EDD Series card STP CIST Port Configuration: CIST Normal Port4 Configuration - STP Enabled |
| 1.3.6.1.4.1.4756.20.442.20.1.541 | ColumneddCISTPort4PathCostRemoteB | read-write | current | EDD Series card STP CIST Port Configuration: CIST Normal Port4 Configuration - Path Cost Valid values are in the range 0 to 200000000. Setting 0 means Auto pat… |
| 1.3.6.1.4.1.4756.20.442.20.1.542 | ColumneddCISTPort4PriorityRemoteB | read-write | current | EDD Series card STP CIST Port Configuration: CIST Normal Port4 Configuration - Priority |
| 1.3.6.1.4.1.4756.20.442.20.1.543 | ColumneddCISTPort4AdminEdgeRemoteB | read-write | current | EDD Series card STP CIST Port Configuration: CIST Normal Port4 Configuration - STP Enabled 0: Non-edge 1: Edge |
| 1.3.6.1.4.1.4756.20.442.20.1.544 | ColumneddCISTPort4AutoEdgeRemoteB | read-write | current | EDD Series card STP CIST Port Configuration: CIST Normal Port4 Configuration - Auto Edge 0: Non-edge 1: Edge |
| 1.3.6.1.4.1.4756.20.442.20.1.545 | ColumneddCISTPort4RestrictedRoleRemoteB | read-write | current | EDD Series card STP CIST Port Configuration: CIST Normal Port4 Configuration - Restricted Role 0: Non-edge 1: Edge |
| 1.3.6.1.4.1.4756.20.442.20.1.546 | ColumneddCISTPort4RestrictedTCNRemoteB | read-write | current | EDD Series card STP CIST Port Configuration: CIST Normal Port4 Configuration - Restricted TCN 0: Non-edge 1: Edge |
| 1.3.6.1.4.1.4756.20.442.20.1.547 | ColumneddCISTPort4BPDUGuardRemoteB | read-write | current | EDD Series card STP CIST Port Configuration: CIST Normal Port4 Configuration - BPDU Guard 0: Non-edge 1: Edge |
| 1.3.6.1.4.1.4756.20.442.20.1.548 | ColumneddCISTPort4PointToPointRemoteB | read-write | current | EDD Series card STP CIST Port Configuration: CIST Normal Port4 Configuration - Point-to-point 0: Forced True 1: Forced False 2: Auto |
| 1.3.6.1.4.1.4756.20.442.20.1.549 | ColumneddMSTI1AggregatedPathCostRemoteB | read-write | current | EDD Series card MSTI Port Configuration: MSTI1 Aggregated Ports Configuration - Path Cost Valid values are in the range 0 to 200000000. Setting 0 means Auto pa… |
| 1.3.6.1.4.1.4756.20.442.20.1.550 | ColumneddMSTI1AggregatedPriorityRemoteB | read-write | current | EDD Series card MSTI Port Configuration: MSTI1 Aggregated Ports Configuration - Priority |
| 1.3.6.1.4.1.4756.20.442.20.1.551 | ColumneddMSTI1Port1PathCostRemoteB | read-write | current | EDD Series card MSTI Port Configuration: MSTI1 Normal Port1 Configuration - Path Cost Valid values are in the range 0 to 200000000. Setting 0 means Auto path c… |
| 1.3.6.1.4.1.4756.20.442.20.1.552 | ColumneddMSTI1Port1PriorityRemoteB | read-write | current | EDD Series card MSTI Port Configuration: MSTI1 Normal Port1 Configuration - Priority |
| 1.3.6.1.4.1.4756.20.442.20.1.553 | ColumneddMSTI1Port2PathCostRemoteB | read-write | current | EDD Series card MSTI Port Configuration: MSTI1 Normal Port2 Configuration - Path Cost Valid values are in the range 0 to 200000000. Setting 0 means Auto path c… |
| 1.3.6.1.4.1.4756.20.442.20.1.554 | ColumneddMSTI1Port2PriorityRemoteB | read-write | current | EDD Series card MSTI Port Configuration: MSTI1 Normal Port2 Configuration - Priority |
| 1.3.6.1.4.1.4756.20.442.20.1.555 | ColumneddMSTI1Port3PathCostRemoteB | read-write | current | EDD Series card MSTI Port Configuration: MSTI1 Normal Port3 Configuration - Path Cost Valid values are in the range 0 to 200000000. Setting 0 means Auto path c… |
| 1.3.6.1.4.1.4756.20.442.20.1.556 | ColumneddMSTI1Port3PriorityRemoteB | read-write | current | EDD Series card MSTI Port Configuration: MSTI1 Normal Port3 Configuration - Priority |
| 1.3.6.1.4.1.4756.20.442.20.1.557 | ColumneddMSTI1Port4PathCostRemoteB | read-write | current | EDD Series card MSTI Port Configuration: MSTI1 Normal Port4 Configuration - Path Cost Valid values are in the range 0 to 200000000. Setting 0 means Auto path c… |
| 1.3.6.1.4.1.4756.20.442.20.1.558 | ColumneddMSTI1Port4PriorityRemoteB | read-write | current | EDD Series card MSTI Port Configuration: MSTI1 Normal Port4 Configuration - Priority |
| 1.3.6.1.4.1.4756.20.442.20.1.559 | ColumneddMSTI2AggregatedPathCostRemoteB | read-write | current | EDD Series card MSTI Port Configuration: MSTI2 Aggregated Ports Configuration - Path Cost Valid values are in the range 0 to 200000000. Setting 0 means Auto pa… |
| 1.3.6.1.4.1.4756.20.442.20.1.560 | ColumneddMSTI2AggregatedPriorityRemoteB | read-write | current | EDD Series card MSTI Port Configuration: MSTI2 Aggregated Ports Configuration - Priority |
| 1.3.6.1.4.1.4756.20.442.20.1.561 | ColumneddMSTI2Port1PathCostRemoteB | read-write | current | EDD Series card MSTI Port Configuration: MSTI2 Normal Port1 Configuration - Path Cost Valid values are in the range 0 to 200000000. Setting 0 means Auto path c… |
| 1.3.6.1.4.1.4756.20.442.20.1.562 | ColumneddMSTI2Port1PriorityRemoteB | read-write | current | EDD Series card MSTI Port Configuration: MSTI2 Normal Port1 Configuration - Priority |
| 1.3.6.1.4.1.4756.20.442.20.1.563 | ColumneddMSTI2Port2PathCostRemoteB | read-write | current | EDD Series card MSTI Port Configuration: MSTI2 Normal Port2 Configuration - Path Cost Valid values are in the range 0 to 200000000. Setting 0 means Auto path c… |
| 1.3.6.1.4.1.4756.20.442.20.1.564 | ColumneddMSTI2Port2PriorityRemoteB | read-write | current | EDD Series card MSTI Port Configuration: MSTI2 Normal Port2 Configuration - Priority |
| 1.3.6.1.4.1.4756.20.442.20.1.565 | ColumneddMSTI2Port3PathCostRemoteB | read-write | current | EDD Series card MSTI Port Configuration: MSTI2 Normal Port3 Configuration - Path Cost Valid values are in the range 0 to 200000000. Setting 0 means Auto path c… |
| 1.3.6.1.4.1.4756.20.442.20.1.566 | ColumneddMSTI2Port3PriorityRemoteB | read-write | current | EDD Series card MSTI Port Configuration: MSTI2 Normal Port3 Configuration - Priority |
| 1.3.6.1.4.1.4756.20.442.20.1.567 | ColumneddMSTI2Port4PathCostRemoteB | read-write | current | EDD Series card MSTI Port Configuration: MSTI2 Normal Port4 Configuration - Path Cost Valid values are in the range 0 to 200000000. Setting 0 means Auto path c… |
| 1.3.6.1.4.1.4756.20.442.20.1.568 | ColumneddMSTI2Port4PriorityRemoteB | read-write | current | EDD Series card MSTI Port Configuration: MSTI2 Normal Port4 Configuration - Priority |
| 1.3.6.1.4.1.4756.20.442.20.1.569 | ColumneddMSTI3AggregatedPathCostRemoteB | read-write | current | EDD Series card MSTI Port Configuration: MSTI3 Aggregated Ports Configuration - Path Cost Valid values are in the range 0 to 200000000. Setting 0 means Auto pa… |
| 1.3.6.1.4.1.4756.20.442.20.1.570 | ColumneddMSTI3AggregatedPriorityRemoteB | read-write | current | EDD Series card MSTI Port Configuration: MSTI3 Aggregated Ports Configuration - Priority |
| 1.3.6.1.4.1.4756.20.442.20.1.571 | ColumneddMSTI3Port1PathCostRemoteB | read-write | current | EDD Series card MSTI Port Configuration: MSTI3 Normal Port1 Configuration - Path Cost Valid values are in the range 0 to 200000000. Setting 0 means Auto path c… |
| 1.3.6.1.4.1.4756.20.442.20.1.572 | ColumneddMSTI3Port1PriorityRemoteB | read-write | current | EDD Series card MSTI Port Configuration: MSTI3 Normal Port1 Configuration - Priority |
| 1.3.6.1.4.1.4756.20.442.20.1.573 | ColumneddMSTI3Port2PathCostRemoteB | read-write | current | EDD Series card MSTI Port Configuration: MSTI3 Normal Port2 Configuration - Path Cost Valid values are in the range 0 to 200000000. Setting 0 means Auto path c… |
| 1.3.6.1.4.1.4756.20.442.20.1.574 | ColumneddMSTI3Port2PriorityRemoteB | read-write | current | EDD Series card MSTI Port Configuration: MSTI3 Normal Port2 Configuration - Priority |
| 1.3.6.1.4.1.4756.20.442.20.1.575 | ColumneddMSTI3Port3PathCostRemoteB | read-write | current | EDD Series card MSTI Port Configuration: MSTI1 Normal Port3 Configuration - Path Cost Valid values are in the range 0 to 200000000. Setting 0 means Auto path c… |
| 1.3.6.1.4.1.4756.20.442.20.1.576 | ColumneddMSTI3Port3PriorityRemoteB | read-write | current | EDD Series card MSTI Port Configuration: MSTI3 Normal Port3 Configuration - Priority |
| 1.3.6.1.4.1.4756.20.442.20.1.577 | ColumneddMSTI3Port4PathCostRemoteB | read-write | current | EDD Series card MSTI Port Configuration: MSTI3 Normal Port4 Configuration - Path Cost Valid values are in the range 0 to 200000000. Setting 0 means Auto path c… |
| 1.3.6.1.4.1.4756.20.442.20.1.578 | ColumneddMSTI3Port4PriorityRemoteB | read-write | current | EDD Series card MSTI Port Configuration: MSTI3 Normal Port4 Configuration - Priority |
| 1.3.6.1.4.1.4756.20.442.20.1.579 | ColumneddMSTI4AggregatedPathCostRemoteB | read-write | current | EDD Series card MSTI Port Configuration: MSTI4 Aggregated Ports Configuration - Path Cost Valid values are in the range 0 to 200000000. Setting 0 means Auto pa… |
| 1.3.6.1.4.1.4756.20.442.20.1.580 | ColumneddMSTI4AggregatedPriorityRemoteB | read-write | current | EDD Series card MSTI Port Configuration: MSTI4 Aggregated Ports Configuration - Priority |
| 1.3.6.1.4.1.4756.20.442.20.1.581 | ColumneddMSTI4Port1PathCostRemoteB | read-write | current | EDD Series card MSTI Port Configuration: MSTI4 Normal Port1 Configuration - Path Cost Valid values are in the range 0 to 200000000. Setting 0 means Auto path c… |
| 1.3.6.1.4.1.4756.20.442.20.1.582 | ColumneddMSTI4Port1PriorityRemoteB | read-write | current | EDD Series card MSTI Port Configuration: MSTI4 Normal Port1 Configuration - Priority |
| 1.3.6.1.4.1.4756.20.442.20.1.583 | ColumneddMSTI4Port2PathCostRemoteB | read-write | current | EDD Series card MSTI Port Configuration: MSTI4 Normal Port2 Configuration - Path Cost Valid values are in the range 0 to 200000000. Setting 0 means Auto path c… |
| 1.3.6.1.4.1.4756.20.442.20.1.584 | ColumneddMSTI4Port2PriorityRemoteB | read-write | current | EDD Series card MSTI Port Configuration: MSTI4 Normal Port2 Configuration - Priority |
| 1.3.6.1.4.1.4756.20.442.20.1.585 | ColumneddMSTI4Port3PathCostRemoteB | read-write | current | EDD Series card MSTI Port Configuration: MSTI1 Normal Port3 Configuration - Path Cost Valid values are in the range 0 to 200000000. Setting 0 means Auto path c… |
| 1.3.6.1.4.1.4756.20.442.20.1.586 | ColumneddMSTI4Port3PriorityRemoteB | read-write | current | EDD Series card MSTI Port Configuration: MSTI4 Normal Port3 Configuration - Priority |
| 1.3.6.1.4.1.4756.20.442.20.1.587 | ColumneddMSTI4Port4PathCostRemoteB | read-write | current | EDD Series card MSTI Port Configuration: MSTI4 Normal Port4 Configuration - Path Cost Valid values are in the range 0 to 200000000. Setting 0 means Auto path c… |
| 1.3.6.1.4.1.4756.20.442.20.1.588 | ColumneddMSTI4Port4PriorityRemoteB | read-write | current | EDD Series card MSTI Port Configuration: MSTI4 Normal Port4 Configuration - Priority |
| 1.3.6.1.4.1.4756.20.442.20.1.589 | ColumneddMSTI5AggregatedPathCostRemoteB | read-write | current | EDD Series card MSTI Port Configuration: MSTI5 Aggregated Ports Configuration - Path Cost Valid values are in the range 0 to 200000000. Setting 0 means Auto pa… |
| 1.3.6.1.4.1.4756.20.442.20.1.590 | ColumneddMSTI5AggregatedPriorityRemoteB | read-write | current | EDD Series card MSTI Port Configuration: MSTI5 Aggregated Ports Configuration - Priority |
| 1.3.6.1.4.1.4756.20.442.20.1.591 | ColumneddMSTI5Port1PathCostRemoteB | read-write | current | EDD Series card MSTI Port Configuration: MSTI5 Normal Port1 Configuration - Path Cost Valid values are in the range 0 to 200000000. Setting 0 means Auto path c… |
| 1.3.6.1.4.1.4756.20.442.20.1.592 | ColumneddMSTI5Port1PriorityRemoteB | read-write | current | EDD Series card MSTI Port Configuration: MSTI5 Normal Port1 Configuration - Priority |
| 1.3.6.1.4.1.4756.20.442.20.1.593 | ColumneddMSTI5Port2PathCostRemoteB | read-write | current | EDD Series card MSTI Port Configuration: MSTI5 Normal Port2 Configuration - Path Cost Valid values are in the range 0 to 200000000. Setting 0 means Auto path c… |
| 1.3.6.1.4.1.4756.20.442.20.1.594 | ColumneddMSTI5Port2PriorityRemoteB | read-write | current | EDD Series card MSTI Port Configuration: MSTI5 Normal Port2 Configuration - Priority |
| 1.3.6.1.4.1.4756.20.442.20.1.595 | ColumneddMSTI5Port3PathCostRemoteB | read-write | current | EDD Series card MSTI Port Configuration: MSTI5 Normal Port3 Configuration - Path Cost Valid values are in the range 0 to 200000000. Setting 0 means Auto path c… |
| 1.3.6.1.4.1.4756.20.442.20.1.596 | ColumneddMSTI5Port3PriorityRemoteB | read-write | current | EDD Series card MSTI Port Configuration: MSTI5 Normal Port3 Configuration - Priority |
| 1.3.6.1.4.1.4756.20.442.20.1.597 | ColumneddMSTI5Port4PathCostRemoteB | read-write | current | EDD Series card MSTI Port Configuration: MSTI5 Normal Port4 Configuration - Path Cost Valid values are in the range 0 to 200000000. Setting 0 means Auto path c… |
| 1.3.6.1.4.1.4756.20.442.20.1.598 | ColumneddMSTI5Port4PriorityRemoteB | read-write | current | EDD Series card MSTI Port Configuration: MSTI5 Normal Port4 Configuration - Priority |
| 1.3.6.1.4.1.4756.20.442.20.1.599 | ColumneddMSTI6AggregatedPathCostRemoteB | read-write | current | EDD Series card MSTI Port Configuration: MSTI6 Aggregated Ports Configuration - Path Cost Valid values are in the range 0 to 200000000. Setting 0 means Auto pa… |
| 1.3.6.1.4.1.4756.20.442.20.1.600 | ColumneddMSTI6AggregatedPriorityRemoteB | read-write | current | EDD Series card MSTI Port Configuration: MSTI6 Aggregated Ports Configuration - Priority |
| 1.3.6.1.4.1.4756.20.442.20.1.601 | ColumneddMSTI6Port1PathCostRemoteB | read-write | current | EDD Series card MSTI Port Configuration: MSTI6 Normal Port1 Configuration - Path Cost Valid values are in the range 0 to 200000000. Setting 0 means Auto path c… |
| 1.3.6.1.4.1.4756.20.442.20.1.602 | ColumneddMSTI6Port1PriorityRemoteB | read-write | current | EDD Series card MSTI Port Configuration: MSTI6 Normal Port1 Configuration - Priority |
| 1.3.6.1.4.1.4756.20.442.20.1.603 | ColumneddMSTI6Port2PathCostRemoteB | read-write | current | EDD Series card MSTI Port Configuration: MSTI6 Normal Port2 Configuration - Path Cost Valid values are in the range 0 to 200000000. Setting 0 means Auto path c… |
| 1.3.6.1.4.1.4756.20.442.20.1.604 | ColumneddMSTI6Port2PriorityRemoteB | read-write | current | EDD Series card MSTI Port Configuration: MSTI6 Normal Port2 Configuration - Priority |
| 1.3.6.1.4.1.4756.20.442.20.1.605 | ColumneddMSTI6Port3PathCostRemoteB | read-write | current | EDD Series card MSTI Port Configuration: MSTI6 Normal Port3 Configuration - Path Cost Valid values are in the range 0 to 200000000. Setting 0 means Auto path c… |
| 1.3.6.1.4.1.4756.20.442.20.1.606 | ColumneddMSTI6Port3PriorityRemoteB | read-write | current | EDD Series card MSTI Port Configuration: MSTI6 Normal Port3 Configuration - Priority |
| 1.3.6.1.4.1.4756.20.442.20.1.607 | ColumneddMSTI6Port4PathCostRemoteB | read-write | current | EDD Series card MSTI Port Configuration: MSTI6 Normal Port4 Configuration - Path Cost Valid values are in the range 0 to 200000000. Setting 0 means Auto path c… |
| 1.3.6.1.4.1.4756.20.442.20.1.608 | ColumneddMSTI6Port4PriorityRemoteB | read-write | current | EDD Series card MSTI Port Configuration: MSTI6 Normal Port4 Configuration - Priority |
| 1.3.6.1.4.1.4756.20.442.20.1.609 | ColumneddMSTI7AggregatedPathCostRemoteB | read-write | current | EDD Series card MSTI Port Configuration: MSTI7 Aggregated Ports Configuration - Path Cost Valid values are in the range 0 to 200000000. Setting 0 means Auto pa… |
| 1.3.6.1.4.1.4756.20.442.20.1.610 | ColumneddMSTI7AggregatedPriorityRemoteB | read-write | current | EDD Series card MSTI Port Configuration: MSTI7 Aggregated Ports Configuration - Priority |
| 1.3.6.1.4.1.4756.20.442.20.1.611 | ColumneddMSTI7Port1PathCostRemoteB | read-write | current | EDD Series card MSTI Port Configuration: MSTI1 Normal Port1 Configuration - Path Cost Valid values are in the range 0 to 200000000. Setting 0 means Auto path c… |
| 1.3.6.1.4.1.4756.20.442.20.1.612 | ColumneddMSTI7Port1PriorityRemoteB | read-write | current | EDD Series card MSTI Port Configuration: MSTI1 Normal Port7 Configuration - Priority |
| 1.3.6.1.4.1.4756.20.442.20.1.613 | ColumneddMSTI7Port2PathCostRemoteB | read-write | current | EDD Series card MSTI Port Configuration: MSTI7 Normal Port2 Configuration - Path Cost Valid values are in the range 0 to 200000000. Setting 0 means Auto path c… |
| 1.3.6.1.4.1.4756.20.442.20.1.614 | ColumneddMSTI7Port2PriorityRemoteB | read-write | current | EDD Series card MSTI Port Configuration: MSTI7 Normal Port2 Configuration - Priority |
| 1.3.6.1.4.1.4756.20.442.20.1.615 | ColumneddMSTI7Port3PathCostRemoteB | read-write | current | EDD Series card MSTI Port Configuration: MSTI7 Normal Port3 Configuration - Path Cost Valid values are in the range 0 to 200000000. Setting 0 means Auto path c… |
| 1.3.6.1.4.1.4756.20.442.20.1.616 | ColumneddMSTI7Port3PriorityRemoteB | read-write | current | EDD Series card MSTI Port Configuration: MSTI7 Normal Port3 Configuration - Priority |
| 1.3.6.1.4.1.4756.20.442.20.1.617 | ColumneddMSTI7Port4PathCostRemoteB | read-write | current | EDD Series card MSTI Port Configuration: MSTI7 Normal Port4 Configuration - Path Cost Valid values are in the range 0 to 200000000. Setting 0 means Auto path c… |
| 1.3.6.1.4.1.4756.20.442.20.1.618 | ColumneddMSTI7Port4PriorityRemoteB | read-write | current | EDD Series card MSTI Port Configuration: MSTI7 Normal Port4 Configuration - Priority |
| 1.3.6.1.4.1.4756.20.442.20.1.619 | ColumneddCISTBridgeIDRemoteB | read-only | current | EDD Series card STP Bridges status: CIST - Bridge ID |
| 1.3.6.1.4.1.4756.20.442.20.1.620 | ColumneddCISTRootIDRemoteB | read-only | current | EDD Series card STP Bridges status: CIST - Root ID |
| 1.3.6.1.4.1.4756.20.442.20.1.621 | ColumneddCISTRootPortRemoteB | read-only | current | EDD Series card STP Bridges status: CIST - Root Port |
| 1.3.6.1.4.1.4756.20.442.20.1.622 | ColumneddCISTRootCostRemoteB | read-only | current | EDD Series card STP Bridges status: CIST - Root Cost |
| 1.3.6.1.4.1.4756.20.442.20.1.623 | ColumneddCISTTopologyFlagRemoteB | read-only | current | EDD Series card STP Bridges status: CIST - Topology Flag |
| 1.3.6.1.4.1.4756.20.442.20.1.624 | ColumneddCISTTopologyChangeLastRemoteB | read-only | current | EDD Series card STP Bridges status: CIST - Topology Change Last |
| 1.3.6.1.4.1.4756.20.442.20.1.625 | ColumneddMSTI1BridgeIDRemoteB | read-only | current | EDD Series card STP Bridges status: MSTI1 - Bridge ID |
| 1.3.6.1.4.1.4756.20.442.20.1.626 | ColumneddMSTI1RootIDRemoteB | read-only | current | EDD Series card STP Bridges status: MSTI1 - Root ID |
| 1.3.6.1.4.1.4756.20.442.20.1.627 | ColumneddMSTI1RootPortRemoteB | read-only | current | EDD Series card STP Bridges status: MSTI1 - Root ID |
| 1.3.6.1.4.1.4756.20.442.20.1.628 | ColumneddMSTI1RootCostRemoteB | read-only | current | EDD Series card STP Bridges status: MSTI1 - Root Cost |
| 1.3.6.1.4.1.4756.20.442.20.1.629 | ColumneddMSTI1TopologyFlagRemoteB | read-only | current | EDD Series card STP Bridges status: MSTI1 - Topology Flag |
| 1.3.6.1.4.1.4756.20.442.20.1.630 | ColumneddMSTI1TopologyChangeLastRemoteB | read-only | current | EDD Series card STP Bridges status: MSTI1 - Topology Change Last |
| 1.3.6.1.4.1.4756.20.442.20.1.631 | ColumneddMSTI2BridgeIDRemoteB | read-only | current | EDD Series card STP Bridges status: MSTI2 - Bridge ID |
| 1.3.6.1.4.1.4756.20.442.20.1.632 | ColumneddMSTI2RootIDRemoteB | read-only | current | EDD Series card STP Bridges status: MSTI2 - Root ID |
| 1.3.6.1.4.1.4756.20.442.20.1.633 | ColumneddMSTI2RootPortRemoteB | read-only | current | EDD Series card STP Bridges status: MSTI2 - Root ID |
| 1.3.6.1.4.1.4756.20.442.20.1.634 | ColumneddMSTI2RootCostRemoteB | read-only | current | EDD Series card STP Bridges status: MSTI2 - Root Cost |
| 1.3.6.1.4.1.4756.20.442.20.1.635 | ColumneddMSTI2TopologyFlagRemoteB | read-only | current | EDD Series card STP Bridges status: MSTI2 - Topology Flag |
| 1.3.6.1.4.1.4756.20.442.20.1.636 | ColumneddMSTI2TopologyChangeLastRemoteB | read-only | current | EDD Series card STP Bridges status: MSTI2 - Topology Change Last |
| 1.3.6.1.4.1.4756.20.442.20.1.637 | ColumneddMSTI3BridgeIDRemoteB | read-only | current | EDD Series card STP Bridges status: MSTI3 - Bridge ID |
| 1.3.6.1.4.1.4756.20.442.20.1.638 | ColumneddMSTI3RootIDRemoteB | read-only | current | EDD Series card STP Bridges status: MSTI3 - Root ID |
| 1.3.6.1.4.1.4756.20.442.20.1.639 | ColumneddMSTI3RootPortRemoteB | read-only | current | EDD Series card STP Bridges status: MSTI3 - Root ID |
| 1.3.6.1.4.1.4756.20.442.20.1.640 | ColumneddMSTI3RootCostRemoteB | read-only | current | EDD Series card STP Bridges status: MSTI3 - Root Cost |
| 1.3.6.1.4.1.4756.20.442.20.1.641 | ColumneddMSTI3TopologyFlagRemoteB | read-only | current | EDD Series card STP Bridges status: MSTI3 - Topology Flag |
| 1.3.6.1.4.1.4756.20.442.20.1.642 | ColumneddMSTI3TopologyChangeLastRemoteB | read-only | current | EDD Series card STP Bridges status: MSTI3 - Topology Change Last |
| 1.3.6.1.4.1.4756.20.442.20.1.643 | ColumneddMSTI4BridgeIDRemoteB | read-only | current | EDD Series card STP Bridges status: MSTI4 - Bridge ID |
| 1.3.6.1.4.1.4756.20.442.20.1.644 | ColumneddMSTI4RootIDRemoteB | read-only | current | EDD Series card STP Bridges status: MSTI4 - Root ID |
| 1.3.6.1.4.1.4756.20.442.20.1.645 | ColumneddMSTI4RootPortRemoteB | read-only | current | EDD Series card STP Bridges status: MSTI4 - Root ID |
| 1.3.6.1.4.1.4756.20.442.20.1.646 | ColumneddMSTI4RootCostRemoteB | read-only | current | EDD Series card STP Bridges status: MSTI4 - Root Cost |
| 1.3.6.1.4.1.4756.20.442.20.1.647 | ColumneddMSTI4TopologyFlagRemoteB | read-only | current | EDD Series card STP Bridges status: MSTI4 - Topology Flag |
| 1.3.6.1.4.1.4756.20.442.20.1.648 | ColumneddMSTI4TopologyChangeLastRemoteB | read-only | current | EDD Series card STP Bridges status: MSTI4 - Topology Change Last |
| 1.3.6.1.4.1.4756.20.442.20.1.649 | ColumneddMSTI5BridgeIDRemoteB | read-only | current | EDD Series card STP Bridges status: MSTI5 - Bridge ID |
| 1.3.6.1.4.1.4756.20.442.20.1.650 | ColumneddMSTI5RootIDRemoteB | read-only | current | EDD Series card STP Bridges status: MSTI5 - Root ID |
| 1.3.6.1.4.1.4756.20.442.20.1.651 | ColumneddMSTI5RootPortRemoteB | read-only | current | EDD Series card STP Bridges status: MSTI5 - Root ID |
| 1.3.6.1.4.1.4756.20.442.20.1.652 | ColumneddMSTI5RootCostRemoteB | read-only | current | EDD Series card STP Bridges status: MSTI5 - Root Cost |
| 1.3.6.1.4.1.4756.20.442.20.1.653 | ColumneddMSTI5TopologyFlagRemoteB | read-only | current | EDD Series card STP Bridges status: MSTI5 - Topology Flag |
| 1.3.6.1.4.1.4756.20.442.20.1.654 | ColumneddMSTI5TopologyChangeLastRemoteB | read-only | current | EDD Series card STP Bridges status: MSTI5 - Topology Change Last |
| 1.3.6.1.4.1.4756.20.442.20.1.655 | ColumneddMSTI6BridgeIDRemoteB | read-only | current | EDD Series card STP Bridges status: MSTI6 - Bridge ID |
| 1.3.6.1.4.1.4756.20.442.20.1.656 | ColumneddMSTI6RootIDRemoteB | read-only | current | EDD Series card STP Bridges status: MSTI6 - Root ID |
| 1.3.6.1.4.1.4756.20.442.20.1.657 | ColumneddMSTI6RootPortRemoteB | read-only | current | EDD Series card STP Bridges status: MSTI6 - Root ID |
| 1.3.6.1.4.1.4756.20.442.20.1.658 | ColumneddMSTI6RootCostRemoteB | read-only | current | EDD Series card STP Bridges status: MSTI6 - Root Cost |
| 1.3.6.1.4.1.4756.20.442.20.1.659 | ColumneddMSTI6TopologyFlagRemoteB | read-only | current | EDD Series card STP Bridges status: MSTI6 - Topology Flag |
| 1.3.6.1.4.1.4756.20.442.20.1.660 | ColumneddMSTI6TopologyChangeLastRemoteB | read-only | current | EDD Series card STP Bridges status: MSTI6 - Topology Change Last |
| 1.3.6.1.4.1.4756.20.442.20.1.661 | ColumneddMSTI7BridgeIDRemoteB | read-only | current | EDD Series card STP Bridges status: MSTI7 - Bridge ID |
| 1.3.6.1.4.1.4756.20.442.20.1.662 | ColumneddMSTI7RootIDRemoteB | read-only | current | EDD Series card STP Bridges status: MSTI7 - Root ID |
| 1.3.6.1.4.1.4756.20.442.20.1.663 | ColumneddMSTI7RootPortRemoteB | read-only | current | EDD Series card STP Bridges status: MSTI7 - Root ID |
| 1.3.6.1.4.1.4756.20.442.20.1.664 | ColumneddMSTI7RootCostRemoteB | read-only | current | EDD Series card STP Bridges status: MSTI7 - Root Cost |
| 1.3.6.1.4.1.4756.20.442.20.1.665 | ColumneddMSTI7TopologyFlagRemoteB | read-only | current | EDD Series card STP Bridges status: MSTI7 - Topology Flag |
| 1.3.6.1.4.1.4756.20.442.20.1.666 | ColumneddMSTI7TopologyChangeLastRemoteB | read-only | current | EDD Series card STP Bridges status: MSTI7 - Topology Change Last |
| 1.3.6.1.4.1.4756.20.442.20.1.667 | ColumneddSTPPortStatusInst1PortRemoteB | read-only | current | EDD Series card STP Port status: Instance1 - Port |
| 1.3.6.1.4.1.4756.20.442.20.1.668 | ColumneddSTPPortStatusInst1CISTRoleRemoteB | read-only | current | EDD Series card STP Port status: Instance1 - CIST Role |
| 1.3.6.1.4.1.4756.20.442.20.1.669 | ColumneddSTPPortStatusInst1CISTStateRemoteB | read-only | current | EDD Series card STP Port status: Instance1 - CIST State |
| 1.3.6.1.4.1.4756.20.442.20.1.670 | ColumneddSTPPortStatusInst1UptimeRemoteB | read-only | current | EDD Series card STP Port status: Instance1 -Uptime |
| 1.3.6.1.4.1.4756.20.442.20.1.671 | ColumneddSTPPortStatusInst2PortRemoteB | read-only | current | EDD Series card STP Port status: Instance2 - Port |
| 1.3.6.1.4.1.4756.20.442.20.1.672 | ColumneddSTPPortStatusInst2CISTRoleRemoteB | read-only | current | EDD Series card STP Port status: Instance2 - CIST Role |
| 1.3.6.1.4.1.4756.20.442.20.1.673 | ColumneddSTPPortStatusInst2CISTStateRemoteB | read-only | current | EDD Series card STP Port status: Instance2 - CIST State |
| 1.3.6.1.4.1.4756.20.442.20.1.674 | ColumneddSTPPortStatusInst2UptimeRemoteB | read-only | current | EDD Series card STP Port status: Instance2 -Uptime |
| 1.3.6.1.4.1.4756.20.442.20.1.675 | ColumneddSTPPortStatusInst3PortRemoteB | read-only | current | EDD Series card STP Port status: Instance3 - Port |
| 1.3.6.1.4.1.4756.20.442.20.1.676 | ColumneddSTPPortStatusInst3CISTRoleRemoteB | read-only | current | EDD Series card STP Port status: Instance3 - CIST Role |
| 1.3.6.1.4.1.4756.20.442.20.1.677 | ColumneddSTPPortStatusInst3CISTStateRemoteB | read-only | current | EDD Series card STP Port status: Instance3 - CIST State |
| 1.3.6.1.4.1.4756.20.442.20.1.678 | ColumneddSTPPortStatusInst3UptimeRemoteB | read-only | current | EDD Series card STP Port status: Instance3 -Uptime |
| 1.3.6.1.4.1.4756.20.442.20.1.679 | ColumneddSTPPortStatusInst4PortRemoteB | read-only | current | EDD Series card STP Port status: Instance4 - Port |
| 1.3.6.1.4.1.4756.20.442.20.1.680 | ColumneddSTPPortStatusInst4CISTRoleRemoteB | read-only | current | EDD Series card STP Port status: Instance4 - CIST Role |
| 1.3.6.1.4.1.4756.20.442.20.1.681 | ColumneddSTPPortStatusInst4CISTStateRemoteB | read-only | current | EDD Series card STP Port status: Instance4 - CIST State |
| 1.3.6.1.4.1.4756.20.442.20.1.682 | ColumneddSTPPortStatusInst4UptimeRemoteB | read-only | current | EDD Series card STP Port status: Instance4 -Uptime |
| 1.3.6.1.4.1.4756.20.442.20.1.683 | ColumneddSTPStatisticsPort1TxMSTPRemoteB | read-only | current | EDD Series card STP Port Statistics: Port1 -Transmitted MSTP |
| 1.3.6.1.4.1.4756.20.442.20.1.684 | ColumneddSTPStatisticsPort1TxRSTPRemoteB | read-only | current | EDD Series card STP Port Statistics: Port1 -Transmitted RSTP |
| 1.3.6.1.4.1.4756.20.442.20.1.685 | ColumneddSTPStatisticsPort1TxSTPRemoteB | read-only | current | EDD Series card STP Port Statistics: Port1 -Transmitted RSTP |
| 1.3.6.1.4.1.4756.20.442.20.1.686 | ColumneddSTPStatisticsPort1TxTCNRemoteB | read-only | current | EDD Series card STP Port Statistics: Port1 -Transmitted RSTP |
| 1.3.6.1.4.1.4756.20.442.20.1.687 | ColumneddSTPStatisticsPort1RxMSTPRemoteB | read-only | current | EDD Series card STP Port Statistics: Port1 -Received MSTP |
| 1.3.6.1.4.1.4756.20.442.20.1.688 | ColumneddSTPStatisticsPort1RxRSTPRemoteB | read-only | current | EDD Series card STP Port Statistics: Port1 -Received RSTP |
| 1.3.6.1.4.1.4756.20.442.20.1.689 | ColumneddSTPStatisticsPort1RxSTPRemoteB | read-only | current | EDD Series card STP Port Statistics: Port1 -Received RSTP |
| 1.3.6.1.4.1.4756.20.442.20.1.690 | ColumneddSTPStatisticsPort1RxTCNRemoteB | read-only | current | EDD Series card STP Port Statistics: Port1 -Received RSTP |
| 1.3.6.1.4.1.4756.20.442.20.1.691 | ColumneddSTPStatisticsPort1DiscardUnknowRemoteB | read-only | current | EDD Series card STP Port Statistics: Port1 -Discarded Unknown |
| 1.3.6.1.4.1.4756.20.442.20.1.692 | ColumneddSTPStatisticsPort1DiscardIllegalRemoteB | read-only | current | EDD Series card STP Port Statistics: Port1 -Discarded Illegal |
| 1.3.6.1.4.1.4756.20.442.20.1.693 | ColumneddSTPStatisticsPort2TxMSTPRemoteB | read-only | current | EDD Series card STP Port Statistics: Port2 -Transmitted MSTP |
| 1.3.6.1.4.1.4756.20.442.20.1.694 | ColumneddSTPStatisticsPort2TxRSTPRemoteB | read-only | current | EDD Series card STP Port Statistics: Port2 -Transmitted RSTP |
| 1.3.6.1.4.1.4756.20.442.20.1.695 | ColumneddSTPStatisticsPort2TxSTPRemoteB | read-only | current | EDD Series card STP Port Statistics: Port2 -Transmitted RSTP |
| 1.3.6.1.4.1.4756.20.442.20.1.696 | ColumneddSTPStatisticsPort2TxTCNRemoteB | read-only | current | EDD Series card STP Port Statistics: Port2 -Transmitted RSTP |
| 1.3.6.1.4.1.4756.20.442.20.1.697 | ColumneddSTPStatisticsPort2RxMSTPRemoteB | read-only | current | EDD Series card STP Port Statistics: Port2 -Received MSTP |
| 1.3.6.1.4.1.4756.20.442.20.1.698 | ColumneddSTPStatisticsPort2RxRSTPRemoteB | read-only | current | EDD Series card STP Port Statistics: Port1 -Received RSTP |
| 1.3.6.1.4.1.4756.20.442.20.1.699 | ColumneddSTPStatisticsPort2RxSTPRemoteB | read-only | current | EDD Series card STP Port Statistics: Port2 -Received RSTP |
| 1.3.6.1.4.1.4756.20.442.20.1.700 | ColumneddSTPStatisticsPort2RxTCNRemoteB | read-only | current | EDD Series card STP Port Statistics: Port2 -Received RSTP |
| 1.3.6.1.4.1.4756.20.442.20.1.701 | ColumneddSTPStatisticsPort2DiscardUnknowRemoteB | read-only | current | EDD Series card STP Port Statistics: Port2 -Discarded Unknown |
| 1.3.6.1.4.1.4756.20.442.20.1.702 | ColumneddSTPStatisticsPort2DiscardIllegalRemoteB | read-only | current | EDD Series card STP Port Statistics: Port2 -Discarded Illegal |
| 1.3.6.1.4.1.4756.20.442.20.1.703 | ColumneddSTPStatisticsPort3TxMSTPRemoteB | read-only | current | EDD Series card STP Port Statistics: Port3 -Transmitted MSTP |
| 1.3.6.1.4.1.4756.20.442.20.1.704 | ColumneddSTPStatisticsPort3TxRSTPRemoteB | read-only | current | EDD Series card STP Port Statistics: Port3 -Transmitted RSTP |
| 1.3.6.1.4.1.4756.20.442.20.1.705 | ColumneddSTPStatisticsPort3TxSTPRemoteB | read-only | current | EDD Series card STP Port Statistics: Port3 -Transmitted RSTP |
| 1.3.6.1.4.1.4756.20.442.20.1.706 | ColumneddSTPStatisticsPort3TxTCNRemoteB | read-only | current | EDD Series card STP Port Statistics: Port3 -Transmitted RSTP |
| 1.3.6.1.4.1.4756.20.442.20.1.707 | ColumneddSTPStatisticsPort3RxMSTPRemoteB | read-only | current | EDD Series card STP Port Statistics: Port3 -Received MSTP |
| 1.3.6.1.4.1.4756.20.442.20.1.708 | ColumneddSTPStatisticsPort3RxRSTPRemoteB | read-only | current | EDD Series card STP Port Statistics: Port3 -Received RSTP |
| 1.3.6.1.4.1.4756.20.442.20.1.709 | ColumneddSTPStatisticsPort3RxSTPRemoteB | read-only | current | EDD Series card STP Port Statistics: Port3 -Received RSTP |
| 1.3.6.1.4.1.4756.20.442.20.1.710 | ColumneddSTPStatisticsPort3RxTCNRemoteB | read-only | current | EDD Series card STP Port Statistics: Port3 -Received RSTP |
| 1.3.6.1.4.1.4756.20.442.20.1.711 | ColumneddSTPStatisticsPort3DiscardUnknowRemoteB | read-only | current | EDD Series card STP Port Statistics: Port3 -Discarded Unknown |
| 1.3.6.1.4.1.4756.20.442.20.1.712 | ColumneddSTPStatisticsPort3DiscardIllegalRemoteB | read-only | current | EDD Series card STP Port Statistics: Port3 -Discarded Illegal |
| 1.3.6.1.4.1.4756.20.442.20.1.713 | ColumneddSTPStatisticsPort4TxMSTPRemoteB | read-only | current | EDD Series card STP Port Statistics: Port4 -Transmitted MSTP |
| 1.3.6.1.4.1.4756.20.442.20.1.714 | ColumneddSTPStatisticsPort4TxRSTPRemoteB | read-only | current | EDD Series card STP Port Statistics: Port4 -Transmitted RSTP |
| 1.3.6.1.4.1.4756.20.442.20.1.715 | ColumneddSTPStatisticsPort4TxSTPRemoteB | read-only | current | EDD Series card STP Port Statistics: Port4 -Transmitted RSTP |
| 1.3.6.1.4.1.4756.20.442.20.1.716 | ColumneddSTPStatisticsPort4TxTCNRemoteB | read-only | current | EDD Series card STP Port Statistics: Port4 -Transmitted RSTP |
| 1.3.6.1.4.1.4756.20.442.20.1.717 | ColumneddSTPStatisticsPort4RxMSTPRemoteB | read-only | current | EDD Series card STP Port Statistics: Port4 -Received MSTP |
| 1.3.6.1.4.1.4756.20.442.20.1.718 | ColumneddSTPStatisticsPort4RxRSTPRemoteB | read-only | current | EDD Series card STP Port Statistics: Port4 -Received RSTP |
| 1.3.6.1.4.1.4756.20.442.20.1.719 | ColumneddSTPStatisticsPort4RxSTPRemoteB | read-only | current | EDD Series card STP Port Statistics: Port4 -Received RSTP |
| 1.3.6.1.4.1.4756.20.442.20.1.720 | ColumneddSTPStatisticsPort4RxTCNRemoteB | read-only | current | EDD Series card STP Port Statistics: Port4 -Received RSTP |
| 1.3.6.1.4.1.4756.20.442.20.1.721 | ColumneddSTPStatisticsPort4DiscardUnknowRemoteB | read-only | current | EDD Series card STP Port Statistics: Port4 -Discarded Unknown |
| 1.3.6.1.4.1.4756.20.442.20.1.722 | ColumneddSTPStatisticsPort4DiscardIllegalRemoteB | read-only | current | EDD Series card STP Port Statistics: Port4 -Discarded Illegal |
| 1.3.6.1.4.1.4756.20.442.20.1.723 | ColumneddSTPStatisticsPortClearCounterRemoteB | read-write | current | EDD Series card STP Port Statistics: Clear Counters 0: OFff 1: Action |
| 1.3.6.1.4.1.4756.20.442.20.1.724 | ColumneddAllowedAccessVLANsRemoteB | read-write | current | EDD Series card Global VLAN Configuration: Allowed Access VLANs By default, only VLAN 1 is enabled. More VLANs may be created by using a list syntax where the … |
| 1.3.6.1.4.1.4756.20.442.20.1.725 | ColumneddVlanEthertypeRemoteB | read-write | current | EDD Series card Global VLAN Configuration: Ethertype for Custom S-ports The format of 'Ethernet Type' is restricted to 0x600-0xFFFF |
| 1.3.6.1.4.1.4756.20.442.20.1.726 | ColumneddPort1VlanModeRemoteB | read-write | current | EDD Series card Port VLAN Configuration : Port1 - Mode 0: Access 1: Trunk 2: Hybrid |
| 1.3.6.1.4.1.4756.20.442.20.1.727 | ColumneddPort1VlanIDRemoteB | read-write | current | EDD Series card Port VLAN Configuration : Port1 - VLAN ID |
| 1.3.6.1.4.1.4756.20.442.20.1.728 | ColumneddPort1VlanTypeRemoteB | read-write | current | EDD Series card Port VLAN Configuration : Port1 - VLAN Type 0: Unaware 1: C-port 2: S-port 3: S-custom-port |
| 1.3.6.1.4.1.4756.20.442.20.1.729 | ColumneddPort1VlanIngressFilteringRemoteB | read-write | current | EDD Series card Port VLAN Configuration : Port1 - Ingress Filtering 0: Off 1: On |
| 1.3.6.1.4.1.4756.20.442.20.1.730 | ColumneddPort1VlanIngressAcceptanceRemoteB | read-write | current | EDD Series card Port VLAN Configuration : Port1 - Ingress Acceptance 0: Tagged and untagged 1: Tagged only 2: Untagged only |
| 1.3.6.1.4.1.4756.20.442.20.1.731 | ColumneddPort1VlanEgressTaggingRemoteB | read-write | current | EDD Series card Port VLAN Configuration : Port1 - Egress Tagging 0: Untag port vlan 1: Tag all 2: Untag all |
| 1.3.6.1.4.1.4756.20.442.20.1.732 | ColumneddPort1AllowedVLANSRemoteB | read-write | current | EDD Series card Global VLAN Configuration: Port1 - Allowed VLANs By default, only VLAN 1 is enabled. More VLANs may be created by using a list syntax where the… |
| 1.3.6.1.4.1.4756.20.442.20.1.733 | ColumneddPort1ForbiddenVLANSRemoteB | read-write | current | EDD Series card Global VLAN Configuration: Port1 - Forbidden VLANs By default, the field is left blank, which means that the port may become a member of all po… |
| 1.3.6.1.4.1.4756.20.442.20.1.734 | ColumneddPort2VlanModeRemoteB | read-write | current | EDD Series card Port VLAN Configuration : Port2 - Mode 0: Access 1: Trunk 2: Hybrid |
| 1.3.6.1.4.1.4756.20.442.20.1.735 | ColumneddPort2VlanIDRemoteB | read-write | current | EDD Series card Port VLAN Configuration : Port2 - VLAN ID |
| 1.3.6.1.4.1.4756.20.442.20.1.736 | ColumneddPort2VlanTypeRemoteB | read-write | current | EDD Series card Port VLAN Configuration : Port2 - VLAN Type 0: Unaware 1: C-port 2: S-port 3: S-custom-port |
| 1.3.6.1.4.1.4756.20.442.20.1.737 | ColumneddPort2VlanIngressFilteringRemoteB | read-write | current | EDD Series card Port VLAN Configuration : Port2 - Ingress Filtering 0: Off 1: On |
| 1.3.6.1.4.1.4756.20.442.20.1.738 | ColumneddPort2VlanIngressAcceptanceRemoteB | read-write | current | EDD Series card Port VLAN Configuration : Por2 - Ingress Acceptance 0: Tagged and untagged 1: Tagged only 2: Untagged only |
| 1.3.6.1.4.1.4756.20.442.20.1.739 | ColumneddPort2VlanEgressTaggingRemoteB | read-write | current | EDD Series card Port VLAN Configuration : Port2 - Egress Tagging 0: Untag port vlan 1: Tag all 2: Untag all |
| 1.3.6.1.4.1.4756.20.442.20.1.740 | ColumneddPort2AllowedVLANSRemoteB | read-write | current | EDD Series card Global VLAN Configuration: Port2 - Allowed VLANs By default, only VLAN 1 is enabled. More VLANs may be created by using a list syntax where the… |
| 1.3.6.1.4.1.4756.20.442.20.1.741 | ColumneddPort2ForbiddenVLANSRemoteB | read-write | current | EDD Series card Global VLAN Configuration: Port2 - Forbidden VLANs By default, the field is left blank, which means that the port may become a member of all po… |
| 1.3.6.1.4.1.4756.20.442.20.1.742 | ColumneddPort3VlanModeRemoteB | read-write | current | EDD Series card Port VLAN Configuration : Port3 - Mode 0: Access 1: Trunk 2: Hybrid |
| 1.3.6.1.4.1.4756.20.442.20.1.743 | ColumneddPort3VlanIDRemoteB | read-write | current | EDD Series card Port VLAN Configuration : Port3 - VLAN ID |
| 1.3.6.1.4.1.4756.20.442.20.1.744 | ColumneddPort3VlanTypeRemoteB | read-write | current | EDD Series card Port VLAN Configuration : Port3 - VLAN Type 0: Unaware 1: C-port 2: S-port 3: S-custom-port |
| 1.3.6.1.4.1.4756.20.442.20.1.745 | ColumneddPort3VlanIngressFilteringRemoteB | read-write | current | EDD Series card Port VLAN Configuration : Port3 - Ingress Filtering 0: Off 1: On |
| 1.3.6.1.4.1.4756.20.442.20.1.746 | ColumneddPort3VlanIngressAcceptanceRemoteB | read-write | current | EDD Series card Port VLAN Configuration : Port3 - Ingress Acceptance 0: Tagged and untagged 1: Tagged only 2: Untagged only |
| 1.3.6.1.4.1.4756.20.442.20.1.747 | ColumneddPort3VlanEgressTaggingRemoteB | read-write | current | EDD Series card Port VLAN Configuration : Port3 - Egress Tagging 0: Untag port vlan 1: Tag all 2: Untag all |
| 1.3.6.1.4.1.4756.20.442.20.1.748 | ColumneddPort3AllowedVLANSRemoteB | read-write | current | EDD Series card Global VLAN Configuration: Port3 - Allowed VLANs By default, only VLAN 1 is enabled. More VLANs may be created by using a list syntax where the… |
| 1.3.6.1.4.1.4756.20.442.20.1.749 | ColumneddPort3ForbiddenVLANSRemoteB | read-write | current | EDD Series card Global VLAN Configuration: Port3 - Forbidden VLANs By default, the field is left blank, which means that the port may become a member of all po… |
| 1.3.6.1.4.1.4756.20.442.20.1.750 | ColumneddPort4VlanModeRemoteB | read-write | current | EDD Series card Port VLAN Configuration : Port4 - Mode 0: Access 1: Trunk 2: Hybrid |
| 1.3.6.1.4.1.4756.20.442.20.1.751 | ColumneddPort4VlanIDRemoteB | read-write | current | EDD Series card Port VLAN Configuration : Port4 - VLAN ID |
| 1.3.6.1.4.1.4756.20.442.20.1.752 | ColumneddPort4VlanTypeRemoteB | read-write | current | EDD Series card Port VLAN Configuration : Port4 - VLAN Type 0: Unaware 1: C-port 2: S-port 3: S-custom-port |
| 1.3.6.1.4.1.4756.20.442.20.1.753 | ColumneddPort4VlanIngressFilteringRemoteB | read-write | current | EDD Series card Port VLAN Configuration : Port4 - Ingress Filtering 0: Off 1: On |
| 1.3.6.1.4.1.4756.20.442.20.1.754 | ColumneddPort4VlanIngressAcceptanceRemoteB | read-write | current | EDD Series card Port VLAN Configuration : Port4 - Ingress Acceptance 0: Tagged and untagged 1: Tagged only 2: Untagged only |
| 1.3.6.1.4.1.4756.20.442.20.1.755 | ColumneddPort4VlanEgressTaggingRemoteB | read-write | current | EDD Series card Port VLAN Configuration : Port4 - Egress Tagging 0: Untag port vlan 1: Tag all 2: Untag all |
| 1.3.6.1.4.1.4756.20.442.20.1.756 | ColumneddPort4AllowedVLANSRemoteB | read-write | current | EDD Series card Global VLAN Configuration: Port4 - Allowed VLANs By default, only VLAN 1 is enabled. More VLANs may be created by using a list syntax where the… |
| 1.3.6.1.4.1.4756.20.442.20.1.757 | ColumneddPort4ForbiddenVLANSRemoteB | read-write | current | EDD Series card Global VLAN Configuration: Port4 - Forbidden VLANs By default, the field is left blank, which means that the port may become a member of all po… |
| 1.3.6.1.4.1.4756.20.442.20.1.758 | ColumneddDNSServerTypeRemoteB | read-write | current | EDD Series card IP Configuration: This setting controls the DNS name resolution done by the switch. The following modes are supported: 1:From any DHCP interfac… |
| 1.3.6.1.4.1.4756.20.442.20.1.759 | ColumneddDNSServerSettingRemoteB | read-write | current | EDD Series card IP Configuration: If iDNSServerType setting '3:Configured',this value must setting IP address format as below: Dotted Decimal Notation refers t… |
| 1.3.6.1.4.1.4756.20.442.20.1.760 | ColumneddDNSproxyRemoteB | read-write | current | EDD Series card IP Configuration: When DNS proxy is enabled, system will relay DNS requests to the currently configured DNS server, and reply as a DNS resolver… |
| 1.3.6.1.4.1.4756.20.442.20.1.761 | ColumneddAddIPV4InterfaceRemoteB | read-write | current | EDD Series card IP Interfaces: Add a new IP VLAN Interface: Syntax: [<Interface>] [<vlan_list>] [<IPV4_Addr>] [<IPV4_MASK>] Interface : 1~4 |
| 1.3.6.1.4.1.4756.20.442.20.1.762 | ColumneddDeleteInterfaceRemoteB | read-write | current | EDD Series card IP Interfaces: Delete a IPv4/v6 VLAN Interface: Syntax: [<Interface>] Interface: 1~4 |
| 1.3.6.1.4.1.4756.20.442.20.1.763 | ColumneddIPInterface1VLANRemoteB | read-only | current | EDD Series card IP Interfaces: The VLAN associated with the IP interface. Only ports in this VLAN will be able to access the IP interface. This field is only a… |
| 1.3.6.1.4.1.4756.20.442.20.1.764 | ColumneddIPInterface1DHCPRemoteB | read-write | current | EDD Series card IP Interfaces: DHCP |
| 1.3.6.1.4.1.4756.20.442.20.1.765 | ColumneddIPInterface1FallbackRemoteB | read-write | current | EDD Series card IP Interfaces: Fallback |
| 1.3.6.1.4.1.4756.20.442.20.1.766 | ColumneddIPInterface1IPV4AddressRemoteB | read-only | current | EDD Series card IP Interfaces: IPV4 Address |
| 1.3.6.1.4.1.4756.20.442.20.1.767 | ColumneddIPInterface1IPV4MASKLenRemoteB | read-only | current | EDD Series card IP Interfaces: IPV4 MASK Length |
| 1.3.6.1.4.1.4756.20.442.20.1.768 | ColumneddIPInterface2VLANRemoteB | read-only | current | EDD Series card IP Interfaces: The VLAN associated with the IP interface. Only ports in this VLAN will be able to access the IP interface. This field is only a… |
| 1.3.6.1.4.1.4756.20.442.20.1.769 | ColumneddIPInterface2DHCPRemoteB | read-write | current | EDD Series card IP Interfaces: DHCP |
| 1.3.6.1.4.1.4756.20.442.20.1.770 | ColumneddIPInterface2FallbackRemoteB | read-write | current | EDD Series card IP Interfaces: Fallback |
| 1.3.6.1.4.1.4756.20.442.20.1.771 | ColumneddIPInterface2IPV4AddressRemoteB | read-only | current | EDD Series card IP Interfaces: IPV4 Address |
| 1.3.6.1.4.1.4756.20.442.20.1.772 | ColumneddIPInterface2IPV4MASKLenRemoteB | read-only | current | EDD Series card IP Interfaces: IPV4 MASK Length |
| 1.3.6.1.4.1.4756.20.442.20.1.773 | ColumneddIPInterface3VLANRemoteB | read-only | current | EDD Series card IP Interfaces: The VLAN associated with the IP interface. Only ports in this VLAN will be able to access the IP interface. This field is only a… |
| 1.3.6.1.4.1.4756.20.442.20.1.774 | ColumneddIPInterface3DHCPRemoteB | read-write | current | EDD Series card IP Interfaces: DHCP |
| 1.3.6.1.4.1.4756.20.442.20.1.775 | ColumneddIPInterface3FallbackRemoteB | read-write | current | EDD Series card IP Interfaces: Fallback |
| 1.3.6.1.4.1.4756.20.442.20.1.776 | ColumneddIPInterface3IPV4AddressRemoteB | read-only | current | EDD Series card IP Interfaces: IPV4 Address |
| 1.3.6.1.4.1.4756.20.442.20.1.777 | ColumneddIPInterface3IPV4MASKLenRemoteB | read-only | current | EDD Series card IP Interfaces: IPV4 MASK Length |
| 1.3.6.1.4.1.4756.20.442.20.1.778 | ColumneddIPInterface4VLANRemoteB | read-only | current | EDD Series card IP Interfaces: The VLAN associated with the IP interface. Only ports in this VLAN will be able to access the IP interface. This field is only a… |
| 1.3.6.1.4.1.4756.20.442.20.1.779 | ColumneddIPInterface4DHCPRemoteB | read-write | current | EDD Series card IP Interfaces: DHCP |
| 1.3.6.1.4.1.4756.20.442.20.1.780 | ColumneddIPInterface4FallbackRemoteB | read-write | current | EDD Series card IP Interfaces: Fallback |
| 1.3.6.1.4.1.4756.20.442.20.1.781 | ColumneddIPInterface4IPV4AddressRemoteB | read-only | current | EDD Series card IP Interfaces: IPV4 Address |
| 1.3.6.1.4.1.4756.20.442.20.1.782 | ColumneddIPInterface4IPV4MASKLenRemoteB | read-only | current | EDD Series card IP Interfaces: IPV4 MASK Length |
| 1.3.6.1.4.1.4756.20.442.20.1.783 | ColumneddAddIPV6InterfaceRemoteB | read-write | current | EDD Series card IP Interfaces: Add a new IPv6 VLAN Interface: Syntax: [<Interface>] [<vlan_list>] [<IPV4_Addr>] [<IPV4_MASK>] Interface : 1~4 |
| 1.3.6.1.4.1.4756.20.442.20.1.784 | ColumneddIPInterface1IPV6AddressRemoteB | read-only | current | EDD Series card IP Interfaces: IPV6 Address |
| 1.3.6.1.4.1.4756.20.442.20.1.785 | ColumneddIPInterface1IPV6MASKLenRemoteB | read-only | current | EDD Series card IP Interfaces: IPV6 MASK Length |
| 1.3.6.1.4.1.4756.20.442.20.1.786 | ColumneddIPInterface2IPV6AddressRemoteB | read-only | current | EDD Series card IP Interfaces: IPV6 Address |
| 1.3.6.1.4.1.4756.20.442.20.1.787 | ColumneddIPInterface2IPV6MASKLenRemoteB | read-only | current | EDD Series card IP Interfaces: IPV6 MASK Length |
| 1.3.6.1.4.1.4756.20.442.20.1.788 | ColumneddIPInterface3IPV6AddressRemoteB | read-only | current | EDD Series card IP Interfaces: IPV6 Address |
| 1.3.6.1.4.1.4756.20.442.20.1.789 | ColumneddIPInterface3IPV6MASKLenRemoteB | read-only | current | EDD Series card IP Interfaces: IPV6 MASK Length |
| 1.3.6.1.4.1.4756.20.442.20.1.790 | ColumneddIPInterface4IPV6AddressRemoteB | read-only | current | EDD Series card IP Interfaces: IPV6 Address |
| 1.3.6.1.4.1.4756.20.442.20.1.791 | ColumneddIPInterface4IPV6MASKLenRemoteB | read-only | current | EDD Series card IP Interfaces: IPV6 MASK Length |
| 1.3.6.1.4.1.4756.20.442.20.1.792 | ColumneddPort1ALSRemoteB | read-write | current | EDD Series card Port1 auto laser shutdown: 0: Disable 1: Enable |
| 1.3.6.1.4.1.4756.20.442.20.1.793 | ColumneddPort2ALSRemoteB | read-write | current | EDD Series card Port2 auto laser shutdown: 0: Disable 1: Enable |
| 1.3.6.1.4.1.4756.20.442.20.1.794 | ColumneddPort3ALSRemoteB | read-write | current | EDD Series card Port3 auto laser shutdown (MX210 only): 0: Disable 1: Enable |
| 1.3.6.1.4.1.4756.20.442.20.1.795 | ColumneddPort1LLFLogicRemoteB | read-write | current | EDD Series card Port1 link loss forwarding - Logic 0: AND 1: OR |
| 1.3.6.1.4.1.4756.20.442.20.1.796 | ColumneddPort1LLFLogicPort2RemoteB | read-write | current | EDD Series card Port1 link loss forwarding - Link/Rx Loss Port2 0: NO 1: YES |
| 1.3.6.1.4.1.4756.20.442.20.1.797 | ColumneddPort1LLFLogicPort3RemoteB | read-write | current | EDD Series card Port1 link loss forwarding - Link/Rx Loss Port3 0: NO 1: YES |
| 1.3.6.1.4.1.4756.20.442.20.1.798 | ColumneddPort1LLFLogicPort4RemoteB | read-write | current | EDD Series card Port1 link loss forwarding - Link/Rx Loss Port4 0: NO 1: YES |
| 1.3.6.1.4.1.4756.20.442.20.1.799 | ColumneddPort2LLFLogicRemoteB | read-write | current | EDD Series card Port2 link loss forwarding - Logic 0: AND 1: OR |
| 1.3.6.1.4.1.4756.20.442.20.1.800 | ColumneddPort2LLFLogicPort1RemoteB | read-write | current | EDD Series card Port2 link loss forwarding - Link/Rx Loss Port1 0: NO 1: YES |
| 1.3.6.1.4.1.4756.20.442.20.1.801 | ColumneddPort2LLFLogicPort3RemoteB | read-write | current | EDD Series card Port2 link loss forwarding - Link/Rx Loss Port3 0: NO 1: YES |
| 1.3.6.1.4.1.4756.20.442.20.1.802 | ColumneddPort2LLFLogicPort4RemoteB | read-write | current | EDD Series card Port2 link loss forwarding - Link/Rx Loss Port4 0: NO 1: YES |
| 1.3.6.1.4.1.4756.20.442.20.1.803 | ColumneddPort3LLFLogicRemoteB | read-write | current | EDD Series card Port1 link loss forwarding - Logic 0: AND 1: OR |
| 1.3.6.1.4.1.4756.20.442.20.1.804 | ColumneddPort3LLFLogicPort1RemoteB | read-write | current | EDD Series card Port3 link loss forwarding - Link/Rx Loss Port1 0: NO 1: YES |
| 1.3.6.1.4.1.4756.20.442.20.1.805 | ColumneddPort3LLFLogicPort2RemoteB | read-write | current | EDD Series card Port3 link loss forwarding - Link/Rx Loss Port2 0: NO 1: YES |
| 1.3.6.1.4.1.4756.20.442.20.1.806 | ColumneddPort3LLFLogicPort4RemoteB | read-write | current | EDD Series card Port3 link loss forwarding - Link/Rx Loss Port4 0: NO 1: YES |
| 1.3.6.1.4.1.4756.20.442.20.1.807 | ColumneddPort4LLFLogicRemoteB | read-write | current | EDD Series card Port4 link loss forwarding - Logic 0: AND 1: OR |
| 1.3.6.1.4.1.4756.20.442.20.1.808 | ColumneddPort4LLFLogicPort1RemoteB | read-write | current | EDD Series card Port4 link loss forwarding - Link/Rx Loss Port1 0: NO 1: YES |
| 1.3.6.1.4.1.4756.20.442.20.1.809 | ColumneddPort4LLFLogicPort2RemoteB | read-write | current | EDD Series card Port4 link loss forwarding - Link/Rx Loss Port2 0: NO 1: YES |
| 1.3.6.1.4.1.4756.20.442.20.1.810 | ColumneddPort4LLFLogicPort3RemoteB | read-write | current | EDD Series card Port4 link loss forwarding - Link/Rx Loss Port3 0: NO 1: YES |
| 1.3.6.1.4.1.4756.20.442.20.1.811 | ColumneddQOSPort1IngressRemoteB | read-write | current | EDD Series card QOS Port1 Ingress Enabled 0: NO 1: YES |
| 1.3.6.1.4.1.4756.20.442.20.1.812 | ColumneddQOSPort1IngressRateRemoteB | read-write | current | EDD Series card QOS Port1 Ingress Rate |
| 1.3.6.1.4.1.4756.20.442.20.1.813 | ColumneddQOSPort1IngressRateUnitRemoteB | read-write | current | EDD Series card QOS Port1 Ingress Rate Unit 0: Kbps 1: Mbps 2: fps 3: kfps |
| 1.3.6.1.4.1.4756.20.442.20.1.814 | ColumneddQOSPort1IngressFlowControlRemoteB | read-write | current | EDD Series card QOS Port1 Ingress Flow Control 0: NO 1: YES |
| 1.3.6.1.4.1.4756.20.442.20.1.815 | ColumneddQOSPort2IngressRemoteB | read-write | current | EDD Series card QOS Port2 Ingress Enabled 0: NO 1: YES |
| 1.3.6.1.4.1.4756.20.442.20.1.816 | ColumneddQOSPort2IngressRateRemoteB | read-write | current | EDD Series card QOS Port2 Ingress Rate |
| 1.3.6.1.4.1.4756.20.442.20.1.817 | ColumneddQOSPort2IngressRateUnitRemoteB | read-write | current | EDD Series card QOS Port2 Ingress Rate Unit 0: Kbps 1: Mbps 2: fps 3: kfps |
| 1.3.6.1.4.1.4756.20.442.20.1.818 | ColumneddQOSPort2IngressFlowControlRemoteB | read-write | current | EDD Series card QOS Port2 Ingress Flow Control 0: NO 1: YES |
| 1.3.6.1.4.1.4756.20.442.20.1.819 | ColumneddQOSPort3IngressRemoteB | read-write | current | EDD Series card QOS Port3 Ingress Enabled 0: NO 1: YES |
| 1.3.6.1.4.1.4756.20.442.20.1.820 | ColumneddQOSPort3IngressRateRemoteB | read-write | current | EDD Series card QOS Port3 Ingress Rate |
| 1.3.6.1.4.1.4756.20.442.20.1.821 | ColumneddQOSPort3IngressRateUnitRemoteB | read-write | current | EDD Series card QOS Port3 Ingress Rate Unit 0: Kbps 1: Mbps 2: fps 3: kfps |
| 1.3.6.1.4.1.4756.20.442.20.1.822 | ColumneddQOSPort3IngressFlowControlRemoteB | read-write | current | EDD Series card QOS Port3 Ingress Flow Control 0: NO 1: YES |
| 1.3.6.1.4.1.4756.20.442.20.1.823 | ColumneddQOSPort4IngressRemoteB | read-write | current | EDD Series card QOS Port4 Ingress Enabled 0: NO 1: YES |
| 1.3.6.1.4.1.4756.20.442.20.1.824 | ColumneddQOSPort4IngressRateRemoteB | read-write | current | EDD Series card QOS Port4 Ingress Rate |
| 1.3.6.1.4.1.4756.20.442.20.1.825 | ColumneddQOSPort4IngressRateUnitRemoteB | read-write | current | EDD Series card QOS Port4 Ingress Rate Unit 0: Kbps 1: Mbps 2: fps 3: kfps |
| 1.3.6.1.4.1.4756.20.442.20.1.826 | ColumneddQOSPort4IngressFlowControlRemoteB | read-write | current | EDD Series card QOS Port4 Ingress Flow Control 0: NO 1: YES |
| 1.3.6.1.4.1.4756.20.442.20.1.827 | ColumneddQOSPort1EgressRemoteB | read-write | current | EDD Series card QOS Port1 Egress Enabled 0: NO 1: YES |
| 1.3.6.1.4.1.4756.20.442.20.1.828 | ColumneddQOSPort1EgressRateRemoteB | read-write | current | EDD Series card QOS Port1 Egress Rate |
| 1.3.6.1.4.1.4756.20.442.20.1.829 | ColumneddQOSPort1EgressRateUnitRemoteB | read-write | current | EDD Series card QOS Port1 Egress Rate Unit 0: Kbps 1: Mbps |
| 1.3.6.1.4.1.4756.20.442.20.1.830 | ColumneddQOSPort2EgressRemoteB | read-write | current | EDD Series card QOS Port2 Egress Enabled 0: NO 1: YES |
| 1.3.6.1.4.1.4756.20.442.20.1.831 | ColumneddQOSPort2EgressRateRemoteB | read-write | current | EDD Series card QOS Port2 Egress Rate |
| 1.3.6.1.4.1.4756.20.442.20.1.832 | ColumneddQOSPort2EgressRateUnitRemoteB | read-write | current | EDD Series card QOS Port2 Egress Rate Unit 0: Kbps 1: Mbps |
| 1.3.6.1.4.1.4756.20.442.20.1.833 | ColumneddQOSPort3EgressRemoteB | read-write | current | EDD Series card QOS Port3 Egress Enabled 0: NO 1: YES |
| 1.3.6.1.4.1.4756.20.442.20.1.834 | ColumneddQOSPort3EgressRateRemoteB | read-write | current | EDD Series card QOS Port3 Egress Rate |
| 1.3.6.1.4.1.4756.20.442.20.1.835 | ColumneddQOSPort3EgressRateUnitRemoteB | read-write | current | EDD Series card QOS Port3 Egress Rate Unit 0: Kbps 1: Mbps |
| 1.3.6.1.4.1.4756.20.442.20.1.836 | ColumneddQOSPort4EgressRemoteB | read-write | current | EDD Series card QOS Port4 Egress Enabled 0: NO 1: YES |
| 1.3.6.1.4.1.4756.20.442.20.1.837 | ColumneddQOSPort4EgressRateRemoteB | read-write | current | EDD Series card QOS Port4 Egress Rate |
| 1.3.6.1.4.1.4756.20.442.20.1.838 | ColumneddQOSPort4EgressRateUnitRemoteB | read-write | current | EDD Series card QOS Port4 Egress Rate Unit 0: Kbps 1: Mbps |
| 1.3.6.1.4.1.4756.20.442.20.1.839 | ColumneddQOSUnicastRemoteB | read-write | current | EDD Series card QOS Storm Control Configuration- Unicast 0: NO 1: YES |
| 1.3.6.1.4.1.4756.20.442.20.1.840 | ColumneddQOSUnicastRateRemoteB | read-write | current | EDD Series card QOS Storm Control Configuration- Unicast Rate The rate unit is packets per second (pps). 0: 1 1: 2 2: 4 3: 8 4: 16 5: 32 6: 64 7: 128 8: 256 9:… |
| 1.3.6.1.4.1.4756.20.442.20.1.841 | ColumneddQOSMulticastRemoteB | read-write | current | EDD Series card QOS Storm Control Configuration- Multicast 0: NO 1: YES |
| 1.3.6.1.4.1.4756.20.442.20.1.842 | ColumneddQOSMulticastRateRemoteB | read-write | current | EDD Series card QOS Storm Control Configuration- Multicast The rate unit is packets per second (pps). 0: 1 1: 2 2: 4 3: 8 4: 16 5: 32 6: 64 7: 128 8: 256 9: 51… |
| 1.3.6.1.4.1.4756.20.442.20.1.843 | ColumneddQOSBroadcastRemoteB | read-write | current | EDD Series card QOS Storm Control Configuration- Broadcast 0: NO 1: YES |
| 1.3.6.1.4.1.4756.20.442.20.1.844 | ColumneddQOSBroadcastRateRemoteB | read-write | current | EDD Series card QOS Storm Control Configuration- Broadcast The rate unit is packets per second (pps). 0: 1 1: 2 2: 4 3: 8 4: 16 5: 32 6: 64 7: 128 8: 256 9: 51… |
| 1.3.6.1.4.1.4756.20.442.20.1.845 | ColumneddL2CPPort1DMAC0180C2000000RemoteB | read-write | current | EDD Series card Port 1 L2CP Mode 0180C2000000 0: Forward 1: Peer |
| 1.3.6.1.4.1.4756.20.442.20.1.846 | ColumneddL2CPPort1DMAC0180C2000001RemoteB | read-write | current | EDD Series card Port 1 L2CP Mode 0180C2000001 0: Forward 1: Peer |
| 1.3.6.1.4.1.4756.20.442.20.1.847 | ColumneddL2CPPort1DMAC0180C2000002RemoteB | read-write | current | EDD Series card Port 1 L2CP Mode 0180C2000002 0: Forward 1: Peer |
| 1.3.6.1.4.1.4756.20.442.20.1.848 | ColumneddL2CPPort1DMAC0180C2000003RemoteB | read-write | current | EDD Series card Port 1 L2CP Mode 0180C2000003 0: Forward 1: Peer |
| 1.3.6.1.4.1.4756.20.442.20.1.849 | ColumneddL2CPPort1DMAC0180C2000004RemoteB | read-write | current | EDD Series card Port 1 L2CP Mode 0180C2000004 0: Forward 1: Peer |
| 1.3.6.1.4.1.4756.20.442.20.1.850 | ColumneddL2CPPort1DMAC0180C2000005RemoteB | read-write | current | EDD Series card Port 1 L2CP Mode 0180C2000005 0: Forward 1: Peer |
| 1.3.6.1.4.1.4756.20.442.20.1.851 | ColumneddL2CPPort1DMAC0180C2000006RemoteB | read-write | current | EDD Series card Port 1 L2CP Mode 0180C2000006 0: Forward 1: Peer |
| 1.3.6.1.4.1.4756.20.442.20.1.852 | ColumneddL2CPPort1DMAC0180C2000007RemoteB | read-write | current | EDD Series card Port 1 L2CP Mode 0180C2000007 0: Forward 1: Peer |
| 1.3.6.1.4.1.4756.20.442.20.1.853 | ColumneddL2CPPort1DMAC0180C2000008RemoteB | read-write | current | EDD Series card Port 1 L2CP Mode 0180C2000008 0: Forward 1: Peer |
| 1.3.6.1.4.1.4756.20.442.20.1.854 | ColumneddL2CPPort1DMAC0180C2000009RemoteB | read-write | current | EDD Series card Port 1 L2CP Mode 0180C2000009 0: Forward 1: Peer |
| 1.3.6.1.4.1.4756.20.442.20.1.855 | ColumneddL2CPPort1DMAC0180C200000ARemoteB | read-write | current | EDD Series card Port 1 L2CP Mode 0180C200000A 0: Forward 1: Peer |
| 1.3.6.1.4.1.4756.20.442.20.1.856 | ColumneddL2CPPort1DMAC0180C200000BRemoteB | read-write | current | EDD Series card Port 1 L2CP Mode 0180C200000B 0: Forward 1: Peer |
| 1.3.6.1.4.1.4756.20.442.20.1.857 | ColumneddL2CPPort1DMAC0180C200000CRemoteB | read-write | current | EDD Series card Port 1 L2CP Mode 0180C200000C 0: Forward 1: Peer |
| 1.3.6.1.4.1.4756.20.442.20.1.858 | ColumneddL2CPPort1DMAC0180C200000DRemoteB | read-write | current | EDD Series card Port 1 L2CP Mode 0180C200000D 0: Forward 1: Peer |
| 1.3.6.1.4.1.4756.20.442.20.1.859 | ColumneddL2CPPort1DMAC0180C200000ERemoteB | read-write | current | EDD Series card Port 1 L2CP Mode 0180C200000E 0: Forward 1: Peer |
| 1.3.6.1.4.1.4756.20.442.20.1.860 | ColumneddL2CPPort1DMAC0180C200000FRemoteB | read-write | current | EDD Series card Port 1 L2CP Mode 0180C200000F 0: Forward 1: Peer |
| 1.3.6.1.4.1.4756.20.442.20.1.861 | ColumneddL2CPPort1DMAC0180C2000010RemoteB | read-write | current | EDD Series card Port 1 L2CP Mode 0180C2000010 0: Forward 1: Peer |
| 1.3.6.1.4.1.4756.20.442.20.1.862 | ColumneddL2CPPort1DMAC0180C2000020RemoteB | read-write | current | EDD Series card Port 1 L2CP Mode 0180C2000020 0: Forward 1: Peer |
| 1.3.6.1.4.1.4756.20.442.20.1.863 | ColumneddL2CPPort1DMAC0180C2000021RemoteB | read-write | current | EDD Series card Port 1 L2CP Mode 0180C2000021 0: Forward 1: Peer |
| 1.3.6.1.4.1.4756.20.442.20.1.864 | ColumneddL2CPPort1DMAC0180C2000022RemoteB | read-write | current | EDD Series card Port 1 L2CP Mode 0180C2000022 0: Forward 1: Peer |
| 1.3.6.1.4.1.4756.20.442.20.1.865 | ColumneddL2CPPort1DMAC0180C2000023RemoteB | read-write | current | EDD Series card Port 1 L2CP Mode 0180C2000023 0: Forward 1: Peer |
| 1.3.6.1.4.1.4756.20.442.20.1.866 | ColumneddL2CPPort1DMAC0180C2000024RemoteB | read-write | current | EDD Series card Port 1 L2CP Mode 0180C2000024 0: Forward 1: Peer |
| 1.3.6.1.4.1.4756.20.442.20.1.867 | ColumneddL2CPPort1DMAC0180C2000025RemoteB | read-write | current | EDD Series card Port 1 L2CP Mode 0180C2000025 0: Forward 1: Peer |
| 1.3.6.1.4.1.4756.20.442.20.1.868 | ColumneddL2CPPort1DMAC0180C2000026RemoteB | read-write | current | EDD Series card Port 1 L2CP Mode 0180C2000026 0: Forward 1: Peer |
| 1.3.6.1.4.1.4756.20.442.20.1.869 | ColumneddL2CPPort1DMAC0180C2000027RemoteB | read-write | current | EDD Series card Port 1 L2CP Mode 0180C2000027 0: Forward 1: Peer |
| 1.3.6.1.4.1.4756.20.442.20.1.870 | ColumneddL2CPPort1DMAC0180C2000028RemoteB | read-write | current | EDD Series card Port 1 L2CP Mode 0180C2000028 0: Forward 1: Peer |
| 1.3.6.1.4.1.4756.20.442.20.1.871 | ColumneddL2CPPort1DMAC0180C2000029RemoteB | read-write | current | EDD Series card Port 1 L2CP Mode 0180C2000029 0: Forward 1: Peer |
| 1.3.6.1.4.1.4756.20.442.20.1.872 | ColumneddL2CPPort1DMAC0180C200002ARemoteB | read-write | current | EDD Series card Port 1 L2CP Mode 0180C200002A 0: Forward 1: Peer |
| 1.3.6.1.4.1.4756.20.442.20.1.873 | ColumneddL2CPPort1DMAC0180C200002BRemoteB | read-write | current | EDD Series card Port 1 L2CP Mode 0180C200002B 0: Forward 1: Peer |
| 1.3.6.1.4.1.4756.20.442.20.1.874 | ColumneddL2CPPort1DMAC0180C200002CRemoteB | read-write | current | EDD Series card Port 1 L2CP Mode 0180C200002C 0: Forward 1: Peer |
| 1.3.6.1.4.1.4756.20.442.20.1.875 | ColumneddL2CPPort1DMAC0180C200002DRemoteB | read-write | current | EDD Series card Port 1 L2CP Mode 0180C200002D 0: Forward 1: Peer |
| 1.3.6.1.4.1.4756.20.442.20.1.876 | ColumneddL2CPPort1DMAC0180C200002ERemoteB | read-write | current | EDD Series card Port 1 L2CP Mode 0180C200002E 0: Forward 1: Peer |
| 1.3.6.1.4.1.4756.20.442.20.1.877 | ColumneddL2CPPort1DMAC0180C200002FRemoteB | read-write | current | EDD Series card Port 1 L2CP Mode 0180C200002F 0: Forward 1: Peer |
| 1.3.6.1.4.1.4756.20.442.20.1.878 | ColumneddL2CPPort2DMAC0180C2000000RemoteB | read-write | current | EDD Series card Port 2 L2CP Mode 0180C2000000 0: Forward 1: Peer |
| 1.3.6.1.4.1.4756.20.442.20.1.879 | ColumneddL2CPPort2DMAC0180C2000001RemoteB | read-write | current | EDD Series card Port 2 L2CP Mode 0180C2000001 0: Forward 1: Peer |
| 1.3.6.1.4.1.4756.20.442.20.1.880 | ColumneddL2CPPort2DMAC0180C2000002RemoteB | read-write | current | EDD Series card Port 2 L2CP Mode 0180C2000002 0: Forward 1: Peer |
| 1.3.6.1.4.1.4756.20.442.20.1.881 | ColumneddL2CPPort2DMAC0180C2000003RemoteB | read-write | current | EDD Series card Port 2 L2CP Mode 0180C2000003 0: Forward 1: Peer |
| 1.3.6.1.4.1.4756.20.442.20.1.882 | ColumneddL2CPPort2DMAC0180C2000004RemoteB | read-write | current | EDD Series card Port 2 L2CP Mode 0180C2000004 0: Forward 1: Peer |
| 1.3.6.1.4.1.4756.20.442.20.1.883 | ColumneddL2CPPort2DMAC0180C2000005RemoteB | read-write | current | EDD Series card Port 2 L2CP Mode 0180C2000005 0: Forward 1: Peer |
| 1.3.6.1.4.1.4756.20.442.20.1.884 | ColumneddL2CPPort2DMAC0180C2000006RemoteB | read-write | current | EDD Series card Port 2 L2CP Mode 0180C2000006 0: Forward 1: Peer |
| 1.3.6.1.4.1.4756.20.442.20.1.885 | ColumneddL2CPPort2DMAC0180C2000007RemoteB | read-write | current | EDD Series card Port 2 L2CP Mode 0180C2000007 0: Forward 1: Peer |
| 1.3.6.1.4.1.4756.20.442.20.1.886 | ColumneddL2CPPort2DMAC0180C2000008RemoteB | read-write | current | EDD Series card Port 2 L2CP Mode 0180C2000008 0: Forward 1: Peer |
| 1.3.6.1.4.1.4756.20.442.20.1.887 | ColumneddL2CPPort2DMAC0180C2000009RemoteB | read-write | current | EDD Series card Port 2 L2CP Mode 0180C2000009 0: Forward 1: Peer |
| 1.3.6.1.4.1.4756.20.442.20.1.888 | ColumneddL2CPPort2DMAC0180C200000ARemoteB | read-write | current | EDD Series card Port 2 L2CP Mode 0180C200000A 0: Forward 1: Peer |
| 1.3.6.1.4.1.4756.20.442.20.1.889 | ColumneddL2CPPort2DMAC0180C200000BRemoteB | read-write | current | EDD Series card Port 2 L2CP Mode 0180C200000B 0: Forward 1: Peer |
| 1.3.6.1.4.1.4756.20.442.20.1.890 | ColumneddL2CPPort2DMAC0180C200000CRemoteB | read-write | current | EDD Series card Port 2 L2CP Mode 0180C200000C 0: Forward 1: Peer |
| 1.3.6.1.4.1.4756.20.442.20.1.891 | ColumneddL2CPPort2DMAC0180C200000DRemoteB | read-write | current | EDD Series card Port 2 L2CP Mode 0180C200000A 0: Forward 1: Peer |
| 1.3.6.1.4.1.4756.20.442.20.1.892 | ColumneddL2CPPort2DMAC0180C200000ERemoteB | read-write | current | EDD Series card Port 2 L2CP Mode 0180C200000E 0: Forward 1: Peer |
| 1.3.6.1.4.1.4756.20.442.20.1.893 | ColumneddL2CPPort2DMAC0180C200000FRemoteB | read-write | current | EDD Series card Port 2 L2CP Mode 0180C200000F 0: Forward 1: Peer |
| 1.3.6.1.4.1.4756.20.442.20.1.894 | ColumneddL2CPPort2DMAC0180C2000010RemoteB | read-write | current | EDD Series card Port 2 L2CP Mode 0180C2000010 0: Forward 1: Peer |
| 1.3.6.1.4.1.4756.20.442.20.1.895 | ColumneddL2CPPort2DMAC0180C2000020RemoteB | read-write | current | EDD Series card Port 2 L2CP Mode 0180C2000020 0: Forward 1: Peer |
| 1.3.6.1.4.1.4756.20.442.20.1.896 | ColumneddL2CPPort2DMAC0180C2000021RemoteB | read-write | current | EDD Series card Port 2 L2CP Mode 0180C2000021 0: Forward 1: Peer |
| 1.3.6.1.4.1.4756.20.442.20.1.897 | ColumneddL2CPPort2DMAC0180C2000022RemoteB | read-write | current | EDD Series card Port 2 L2CP Mode 0180C2000022 0: Forward 1: Peer |
| 1.3.6.1.4.1.4756.20.442.20.1.898 | ColumneddL2CPPort2DMAC0180C2000023RemoteB | read-write | current | EDD Series card Port 2 L2CP Mode 0180C2000023 0: Forward 1: Peer |
| 1.3.6.1.4.1.4756.20.442.20.1.899 | ColumneddL2CPPort2DMAC0180C2000024RemoteB | read-write | current | EDD Series card Port 2 L2CP Mode 0180C2000024 0: Forward 1: Peer |
| 1.3.6.1.4.1.4756.20.442.20.1.900 | ColumneddL2CPPort2DMAC0180C2000025RemoteB | read-write | current | EDD Series card Port 2 L2CP Mode 0180C2000025 0: Forward 1: Peer |
| 1.3.6.1.4.1.4756.20.442.20.1.901 | ColumneddL2CPPort2DMAC0180C2000026RemoteB | read-write | current | EDD Series card Port 2 L2CP Mode 0180C2000026 0: Forward 1: Peer |
| 1.3.6.1.4.1.4756.20.442.20.1.902 | ColumneddL2CPPort2DMAC0180C2000027RemoteB | read-write | current | EDD Series card Port 2 L2CP Mode 0180C2000027 0: Forward 1: Peer |
| 1.3.6.1.4.1.4756.20.442.20.1.903 | ColumneddL2CPPort2DMAC0180C2000028RemoteB | read-write | current | EDD Series card Port 2 L2CP Mode 0180C2000028 0: Forward 1: Peer |
| 1.3.6.1.4.1.4756.20.442.20.1.904 | ColumneddL2CPPort2DMAC0180C2000029RemoteB | read-write | current | EDD Series card Port 2 L2CP Mode 0180C2000029 0: Forward 1: Peer |
| 1.3.6.1.4.1.4756.20.442.20.1.905 | ColumneddL2CPPort2DMAC0180C200002ARemoteB | read-write | current | EDD Series card Port 2 L2CP Mode 0180C200002A 0: Forward 1: Peer |
| 1.3.6.1.4.1.4756.20.442.20.1.906 | ColumneddL2CPPort2DMAC0180C200002BRemoteB | read-write | current | EDD Series card Port 2 L2CP Mode 0180C200002B 0: Forward 1: Peer |
| 1.3.6.1.4.1.4756.20.442.20.1.907 | ColumneddL2CPPort2DMAC0180C200002CRemoteB | read-write | current | EDD Series card Port 2 L2CP Mode 0180C200002C 0: Forward 1: Peer |
| 1.3.6.1.4.1.4756.20.442.20.1.908 | ColumneddL2CPPort2DMAC0180C200002DRemoteB | read-write | current | EDD Series card Port 2 L2CP Mode 0180C200002D 0: Forward 1: Peer |
| 1.3.6.1.4.1.4756.20.442.20.1.909 | ColumneddL2CPPort2DMAC0180C200002ERemoteB | read-write | current | EDD Series card Port 2 L2CP Mode 0180C200002E 0: Forward 1: Peer |
| 1.3.6.1.4.1.4756.20.442.20.1.910 | ColumneddL2CPPort2DMAC0180C200002FRemoteB | read-write | current | EDD Series card Port 2 L2CP Mode 0180C200002F 0: Forward 1: Peer |
| 1.3.6.1.4.1.4756.20.442.20.1.911 | ColumneddL2CPPort3DMAC0180C2000000RemoteB | read-write | current | EDD Series card Port 3 L2CP Mode 0180C2000000 0: Forward 1: Peer |
| 1.3.6.1.4.1.4756.20.442.20.1.912 | ColumneddL2CPPort3DMAC0180C2000001RemoteB | read-write | current | EDD Series card Port 3 L2CP Mode 0180C2000001 0: Forward 1: Peer |
| 1.3.6.1.4.1.4756.20.442.20.1.913 | ColumneddL2CPPort3DMAC0180C2000002RemoteB | read-write | current | EDD Series card Port 3 L2CP Mode 0180C2000002 0: Forward 1: Peer |
| 1.3.6.1.4.1.4756.20.442.20.1.914 | ColumneddL2CPPort3DMAC0180C2000003RemoteB | read-write | current | EDD Series card Port 3 L2CP Mode 0180C2000003 0: Forward 1: Peer |
| 1.3.6.1.4.1.4756.20.442.20.1.915 | ColumneddL2CPPort3DMAC0180C2000004RemoteB | read-write | current | EDD Series card Port 3 L2CP Mode 0180C2000004 0: Forward 1: Peer |
| 1.3.6.1.4.1.4756.20.442.20.1.916 | ColumneddL2CPPort3DMAC0180C2000005RemoteB | read-write | current | EDD Series card Port 3 L2CP Mode 0180C2000005 0: Forward 1: Peer |
| 1.3.6.1.4.1.4756.20.442.20.1.917 | ColumneddL2CPPort3DMAC0180C2000006RemoteB | read-write | current | EDD Series card Port 3 L2CP Mode 0180C2000006 0: Forward 1: Peer |
| 1.3.6.1.4.1.4756.20.442.20.1.918 | ColumneddL2CPPort3DMAC0180C2000007RemoteB | read-write | current | EDD Series card Port 3 L2CP Mode 0180C2000007 0: Forward 1: Peer |
| 1.3.6.1.4.1.4756.20.442.20.1.919 | ColumneddL2CPPort3DMAC0180C2000008RemoteB | read-write | current | EDD Series card Port 3 L2CP Mode 0180C2000008 0: Forward 1: Peer |
| 1.3.6.1.4.1.4756.20.442.20.1.920 | ColumneddL2CPPort3DMAC0180C2000009RemoteB | read-write | current | EDD Series card Port 3 L2CP Mode 0180C2000009 0: Forward 1: Peer |
| 1.3.6.1.4.1.4756.20.442.20.1.921 | ColumneddL2CPPort3DMAC0180C200000ARemoteB | read-write | current | EDD Series card Port 3 L2CP Mode 0180C200000A 0: Forward 1: Peer |
| 1.3.6.1.4.1.4756.20.442.20.1.922 | ColumneddL2CPPort3DMAC0180C200000BRemoteB | read-write | current | EDD Series card Port 3 L2CP Mode 0180C200000B 0: Forward 1: Peer |
| 1.3.6.1.4.1.4756.20.442.20.1.923 | ColumneddL2CPPort3DMAC0180C200000CRemoteB | read-write | current | EDD Series card Port 3 L2CP Mode 0180C200000C 0: Forward 1: Peer |
| 1.3.6.1.4.1.4756.20.442.20.1.924 | ColumneddL2CPPort3DMAC0180C200000DRemoteB | read-write | current | EDD Series card Port 3 L2CP Mode 0180C200000D 0: Forward 1: Peer |
| 1.3.6.1.4.1.4756.20.442.20.1.925 | ColumneddL2CPPort3DMAC0180C200000ERemoteB | read-write | current | EDD Series card Port 3 L2CP Mode 0180C200000E 0: Forward 1: Peer |
| 1.3.6.1.4.1.4756.20.442.20.1.926 | ColumneddL2CPPort3DMAC0180C200000FRemoteB | read-write | current | EDD Series card Port 3 L2CP Mode 0180C200000F 0: Forward 1: Peer |
| 1.3.6.1.4.1.4756.20.442.20.1.927 | ColumneddL2CPPort3DMAC0180C2000010RemoteB | read-write | current | EDD Series card Port 3 L2CP Mode 0180C2000010 0: Forward 1: Peer |
| 1.3.6.1.4.1.4756.20.442.20.1.928 | ColumneddL2CPPort3DMAC0180C2000020RemoteB | read-write | current | EDD Series card Port 3 L2CP Mode 0180C2000020 0: Forward 1: Peer |
| 1.3.6.1.4.1.4756.20.442.20.1.929 | ColumneddL2CPPort3DMAC0180C2000021RemoteB | read-write | current | EDD Series card Port 3 L2CP Mode 0180C2000021 0: Forward 1: Peer |
| 1.3.6.1.4.1.4756.20.442.20.1.930 | ColumneddL2CPPort3DMAC0180C2000022RemoteB | read-write | current | EDD Series card Port 3 L2CP Mode 0180C2000022 0: Forward 1: Peer |
| 1.3.6.1.4.1.4756.20.442.20.1.931 | ColumneddL2CPPort3DMAC0180C2000023RemoteB | read-write | current | EDD Series card Port 3 L2CP Mode 0180C2000023 0: Forward 1: Peer |
| 1.3.6.1.4.1.4756.20.442.20.1.932 | ColumneddL2CPPort3DMAC0180C2000024RemoteB | read-write | current | EDD Series card Port 3 L2CP Mode 0180C2000024 0: Forward 1: Peer |
| 1.3.6.1.4.1.4756.20.442.20.1.933 | ColumneddL2CPPort3DMAC0180C2000025RemoteB | read-write | current | EDD Series card Port 3 L2CP Mode 0180C2000025 0: Forward 1: Peer |
| 1.3.6.1.4.1.4756.20.442.20.1.934 | ColumneddL2CPPort3DMAC0180C2000026RemoteB | read-write | current | EDD Series card Port 3 L2CP Mode 0180C2000026 0: Forward 1: Peer |
| 1.3.6.1.4.1.4756.20.442.20.1.935 | ColumneddL2CPPort3DMAC0180C2000027RemoteB | read-write | current | EDD Series card Port 3 L2CP Mode 0180C2000027 0: Forward 1: Peer |
| 1.3.6.1.4.1.4756.20.442.20.1.936 | ColumneddL2CPPort3DMAC0180C2000028RemoteB | read-write | current | EDD Series card Port 3 L2CP Mode 0180C2000028 0: Forward 1: Peer |
| 1.3.6.1.4.1.4756.20.442.20.1.937 | ColumneddL2CPPort3DMAC0180C2000029RemoteB | read-write | current | EDD Series card Port 3 L2CP Mode 0180C2000029 0: Forward 1: Peer |
| 1.3.6.1.4.1.4756.20.442.20.1.938 | ColumneddL2CPPort3DMAC0180C200002ARemoteB | read-write | current | EDD Series card Port 3 L2CP Mode 0180C200002A 0: Forward 1: Peer |
| 1.3.6.1.4.1.4756.20.442.20.1.939 | ColumneddL2CPPort3DMAC0180C200002BRemoteB | read-write | current | EDD Series card Port 3 L2CP Mode 0180C200002B 0: Forward 1: Peer |
| 1.3.6.1.4.1.4756.20.442.20.1.940 | ColumneddL2CPPort3DMAC0180C200002CRemoteB | read-write | current | EDD Series card Port 3 L2CP Mode 0180C200002C 0: Forward 1: Peer |
| 1.3.6.1.4.1.4756.20.442.20.1.941 | ColumneddL2CPPort3DMAC0180C200002DRemoteB | read-write | current | EDD Series card Port 3 L2CP Mode 0180C200002D 0: Forward 1: Peer |
| 1.3.6.1.4.1.4756.20.442.20.1.942 | ColumneddL2CPPort3DMAC0180C200002ERemoteB | read-write | current | EDD Series card Port 3 L2CP Mode 0180C200002E 0: Forward 1: Peer |
| 1.3.6.1.4.1.4756.20.442.20.1.943 | ColumneddL2CPPort3DMAC0180C200002FRemoteB | read-write | current | EDD Series card Port 3 L2CP Mode 0180C200002F 0: Forward 1: Peer |
| 1.3.6.1.4.1.4756.20.442.20.1.944 | ColumneddL2CPPort4DMAC0180C2000000RemoteB | read-write | current | EDD Series card Port 4 L2CP Mode 0180C2000000 0: Forward 1: Peer |
| 1.3.6.1.4.1.4756.20.442.20.1.945 | ColumneddL2CPPort4DMAC0180C2000001RemoteB | read-write | current | EDD Series card Port 4 L2CP Mode 0180C2000001 0: Forward 1: Peer |
| 1.3.6.1.4.1.4756.20.442.20.1.946 | ColumneddL2CPPort4DMAC0180C2000002RemoteB | read-write | current | EDD Series card Port 4 L2CP Mode 0180C2000002 0: Forward 1: Peer |
| 1.3.6.1.4.1.4756.20.442.20.1.947 | ColumneddL2CPPort4DMAC0180C2000003RemoteB | read-write | current | EDD Series card Port 4 L2CP Mode 0180C2000003 0: Forward 1: Peer |
| 1.3.6.1.4.1.4756.20.442.20.1.948 | ColumneddL2CPPort4DMAC0180C2000004RemoteB | read-write | current | EDD Series card Port 4 L2CP Mode 0180C2000004 0: Forward 1: Peer |
| 1.3.6.1.4.1.4756.20.442.20.1.949 | ColumneddL2CPPort4DMAC0180C2000005RemoteB | read-write | current | EDD Series card Port 4 L2CP Mode 0180C2000005 0: Forward 1: Peer |
| 1.3.6.1.4.1.4756.20.442.20.1.950 | ColumneddL2CPPort4DMAC0180C2000006RemoteB | read-write | current | EDD Series card Port 4 L2CP Mode 0180C2000006 0: Forward 1: Peer |
| 1.3.6.1.4.1.4756.20.442.20.1.951 | ColumneddL2CPPort4DMAC0180C2000007RemoteB | read-write | current | EDD Series card Port 4 L2CP Mode 0180C2000007 0: Forward 1: Peer |
| 1.3.6.1.4.1.4756.20.442.20.1.952 | ColumneddL2CPPort4DMAC0180C2000008RemoteB | read-write | current | EDD Series card Port 4 L2CP Mode 0180C2000008 0: Forward 1: Peer |
| 1.3.6.1.4.1.4756.20.442.20.1.953 | ColumneddL2CPPort4DMAC0180C2000009RemoteB | read-write | current | EDD Series card Port 4 L2CP Mode 0180C2000009 0: Forward 1: Peer |
| 1.3.6.1.4.1.4756.20.442.20.1.954 | ColumneddL2CPPort4DMAC0180C200000ARemoteB | read-write | current | EDD Series card Port 4 L2CP Mode 0180C200000A 0: Forward 1: Peer |
| 1.3.6.1.4.1.4756.20.442.20.1.955 | ColumneddL2CPPort4DMAC0180C200000BRemoteB | read-write | current | EDD Series card Port 4 L2CP Mode 0180C200000B 0: Forward 1: Peer |
| 1.3.6.1.4.1.4756.20.442.20.1.956 | ColumneddL2CPPort4DMAC0180C200000CRemoteB | read-write | current | EDD Series card Port 4 L2CP Mode 0180C200000C 0: Forward 1: Peer |
| 1.3.6.1.4.1.4756.20.442.20.1.957 | ColumneddL2CPPort4DMAC0180C200000DRemoteB | read-write | current | EDD Series card Port 4 L2CP Mode 0180C200000D 0: Forward 1: Peer |
| 1.3.6.1.4.1.4756.20.442.20.1.958 | ColumneddL2CPPort4DMAC0180C200000ERemoteB | read-write | current | EDD Series card Port 4 L2CP Mode 0180C200000E 0: Forward 1: Peer |
| 1.3.6.1.4.1.4756.20.442.20.1.959 | ColumneddL2CPPort4DMAC0180C200000FRemoteB | read-write | current | EDD Series card Port 4 L2CP Mode 0180C200000F 0: Forward 1: Peer |
| 1.3.6.1.4.1.4756.20.442.20.1.960 | ColumneddL2CPPort4DMAC0180C2000010RemoteB | read-write | current | EDD Series card Port 4 L2CP Mode 0180C2000010 0: Forward 1: Peer |
| 1.3.6.1.4.1.4756.20.442.20.1.961 | ColumneddL2CPPort4DMAC0180C2000020RemoteB | read-write | current | EDD Series card Port 4 L2CP Mode 0180C2000020 0: Forward 1: Peer |
| 1.3.6.1.4.1.4756.20.442.20.1.962 | ColumneddL2CPPort4DMAC0180C2000021RemoteB | read-write | current | EDD Series card Port 4 L2CP Mode 0180C2000021 0: Forward 1: Peer |
| 1.3.6.1.4.1.4756.20.442.20.1.963 | ColumneddL2CPPort4DMAC0180C2000022RemoteB | read-write | current | EDD Series card Port 4 L2CP Mode 0180C2000022 0: Forward 1: Peer |
| 1.3.6.1.4.1.4756.20.442.20.1.964 | ColumneddL2CPPort4DMAC0180C2000023RemoteB | read-write | current | EDD Series card Port 4 L2CP Mode 0180C2000023 0: Forward 1: Peer |
| 1.3.6.1.4.1.4756.20.442.20.1.965 | ColumneddL2CPPort4DMAC0180C2000024RemoteB | read-write | current | EDD Series card Port 4 L2CP Mode 0180C2000024 0: Forward 1: Peer |
| 1.3.6.1.4.1.4756.20.442.20.1.966 | ColumneddL2CPPort4DMAC0180C2000025RemoteB | read-write | current | EDD Series card Port 4 L2CP Mode 0180C2000025 0: Forward 1: Peer |
| 1.3.6.1.4.1.4756.20.442.20.1.967 | ColumneddL2CPPort4DMAC0180C2000026RemoteB | read-write | current | EDD Series card Port 4 L2CP Mode 0180C2000026 0: Forward 1: Peer |
| 1.3.6.1.4.1.4756.20.442.20.1.968 | ColumneddL2CPPort4DMAC0180C2000027RemoteB | read-write | current | EDD Series card Port 4 L2CP Mode 0180C2000027 0: Forward 1: Peer |
| 1.3.6.1.4.1.4756.20.442.20.1.969 | ColumneddL2CPPort4DMAC0180C2000028RemoteB | read-write | current | EDD Series card Port 4 L2CP Mode 0180C2000028 0: Forward 1: Peer |
| 1.3.6.1.4.1.4756.20.442.20.1.970 | ColumneddL2CPPort4DMAC0180C2000029RemoteB | read-write | current | EDD Series card Port 4 L2CP Mode 0180C2000029 0: Forward 1: Peer |
| 1.3.6.1.4.1.4756.20.442.20.1.971 | ColumneddL2CPPort4DMAC0180C200002ARemoteB | read-write | current | EDD Series card Port 4 L2CP Mode 0180C200002A 0: Forward 1: Peer |
| 1.3.6.1.4.1.4756.20.442.20.1.972 | ColumneddL2CPPort4DMAC0180C200002BRemoteB | read-write | current | EDD Series card Port 4 L2CP Mode 0180C200002B 0: Forward 1: Peer |
| 1.3.6.1.4.1.4756.20.442.20.1.973 | ColumneddL2CPPort4DMAC0180C200002CRemoteB | read-write | current | EDD Series card Port 4 L2CP Mode 0180C200002C 0: Forward 1: Peer |
| 1.3.6.1.4.1.4756.20.442.20.1.974 | ColumneddL2CPPort4DMAC0180C200002DRemoteB | read-write | current | EDD Series card Port 4 L2CP Mode 0180C200002D 0: Forward 1: Peer |
| 1.3.6.1.4.1.4756.20.442.20.1.975 | ColumneddL2CPPort4DMAC0180C200002ERemoteB | read-write | current | EDD Series card Port 4 L2CP Mode 0180C200002E 0: Forward 1: Peer |
| 1.3.6.1.4.1.4756.20.442.20.1.976 | ColumneddL2CPPort4DMAC0180C200002FRemoteB | read-write | current | EDD Series card Port 4 L2CP Mode 0180C200002F 0: Forward 1: Peer |
| 1.3.6.1.4.1.4756.20.442.20.1.977 | ColumneddPort1MEPInstanceRemoteB | read-write | current | EDD Series card Port 1 MEP Instance 'MEP ID' must be an integer value between 0 and 8191. |
| 1.3.6.1.4.1.4756.20.442.20.1.978 | ColumneddPort1MEPLogicRemoteB | read-write | current | EDD Series card Port 1 MEP Logic 0: And 1: OR |
| 1.3.6.1.4.1.4756.20.442.20.1.979 | ColumneddPort2MEPInstanceRemoteB | read-write | current | EDD Series card Port 2 MEP Instance 'MEP ID' must be an integer value between 0 and 8191. |
| 1.3.6.1.4.1.4756.20.442.20.1.980 | ColumneddPort2MEPLogicRemoteB | read-write | current | EDD Series card Port 2 MEP Logic 0: And 1: OR |
| 1.3.6.1.4.1.4756.20.442.20.1.981 | ColumneddPort3MEPInstanceRemoteB | read-write | current | EDD Series card Port 3 MEP Instance 'MEP ID' must be an integer value between 0 and 8191. |
| 1.3.6.1.4.1.4756.20.442.20.1.982 | ColumneddPort3MEPLogicRemoteB | read-write | current | EDD Series card Port 3 MEP Logic 0: And 1: OR |
| 1.3.6.1.4.1.4756.20.442.20.1.983 | ColumneddPort4MEPInstanceRemoteB | read-write | current | EDD Series card Port 4 MEP Instance 'MEP ID' must be an integer value between 0 and 8191. |
| 1.3.6.1.4.1.4756.20.442.20.1.984 | ColumneddPort4MEPLogicRemoteB | read-write | current | EDD Series card Port 4 MEP Logic 0: And 1: OR |
| 1.3.6.1.4.1.4756.20.450 | Nodef100AS1LocalCards | |||
| 1.3.6.1.4.1.4756.20.450.40 | Tablef100AS1LocalTable | not-accessible | current | A list of local 100AS-1 card entries. |
| 1.3.6.1.4.1.4756.20.450.40.1 | Rowf100AS1LocalEntry | not-accessible | current | An entry containing management information applicable to a particular local f100AS-1 card. |
| 1.3.6.1.4.1.4756.20.450.40.1.1 | Columnf100AS1ChassisIndexLocal | read-only | current | A unique value for each chassis ID. For CH20, it is the chassis ID. For CH08, it is always 0. |
| 1.3.6.1.4.1.4756.20.450.40.1.2 | Columnf100AS1SlotIndexLocal | read-only | current | A unique value for each local card. It is the slot location number. |
| 1.3.6.1.4.1.4756.20.450.40.1.3 | Columnf100AS1CardHWVerLocal | read-only | current | Local device card hardware version x.xxx |
| 1.3.6.1.4.1.4756.20.450.40.1.4 | Columnf100AS1CardFWVerLocal | read-only | current | Local device card firmware version x.xxx |
| 1.3.6.1.4.1.4756.20.450.40.1.5 | Columnf100AS1CardCPLDVerLocal | read-only | current | Local device card CPLD version x.xxx |
| 1.3.6.1.4.1.4756.20.450.40.1.6 | Columnf100AS1CardFPGAVerLocal | read-only | current | Local device card FPGA version x.xxx |
| 1.3.6.1.4.1.4756.20.450.40.1.7 | Columnf100AS1ModelLocal | read-only | current | Local 100AS-1 Serial Type |
| 1.3.6.1.4.1.4756.20.450.40.1.8 | Columnf100AS1FiberLinkLocal | read-only | current | Local device card fiber port link status: 0:Down 1:Up |
| 1.3.6.1.4.1.4756.20.450.40.1.9 | Columnf100AS1FiberOAMLoopedLocal | read-only | current | Local device card fiber port OAM looped: 0:Off 1:on |
| 1.3.6.1.4.1.4756.20.450.40.1.10 | Columnf100AS1FiberLBTestLocal | read-write | current | Force remote device card to do fiber port LoopBack testing: 0:Off 1:Action |
| 1.3.6.1.4.1.4756.20.450.40.1.11 | Columnf100AS1FiberOAMRLBStatusLocal | read-only | current | Remote device card fiber port LoopBack testing status: 0:Off 1:Ok 2:Fail |
| 1.3.6.1.4.1.4756.20.450.40.1.12 | Columnf100AS1FiberRemoPwrAbLocal | read-only | current | Local device card fiber port 1 Remote Power status: 0:Abnormal 1:OK 2:None |
| 1.3.6.1.4.1.4756.20.450.40.1.13 | Columnf100AS1FiberFEFLocal | read-only | current | Local device card fiber port FEF status: 0:Off 1:Detected |
| 1.3.6.1.4.1.4756.20.450.40.1.14 | Columnf100AS1FiberIngressRateLocal | read-write | current | Local device card fiber Ingress Rate Limit: 0 = Unlimit input format: 64k(K),99m(M),99 If doesn't input the unit, the default was Mega. Limite Rate : 64K ~ 99M |
| 1.3.6.1.4.1.4756.20.450.40.1.15 | Columnf100AS1FiberEgressRateLocal | read-write | current | Local device card fiber Egress Rate Limit: 0 = Unlimit input format: 64k(K),99m(M),99 If doesn't input the unit, the default was Mega. Limite Rate : 64K ~ 99M |
| 1.3.6.1.4.1.4756.20.450.40.1.16 | Columnf100AS1UtpLinkLocal | read-only | current | Local device card UTP port link status: 0:Down 1:Up |
| 1.3.6.1.4.1.4756.20.450.40.1.17 | Columnf100AS1UtpNegoLocal | read-write | current | Local device card UTP port negotiation status: 0:Manual 1:Auto |
| 1.3.6.1.4.1.4756.20.450.40.1.18 | Columnf100AS1UtpSpeedLocal | read-write | current | Local device card UTP port speed setting: 0:10 Base-T 1:100 Base-TX |
| 1.3.6.1.4.1.4756.20.450.40.1.19 | Columnf100AS1UtpDuplexLocal | read-write | current | Local device card UTP port duplex setting: 0:Half duplex mode 1:Full duplex mode |
| 1.3.6.1.4.1.4756.20.450.40.1.20 | Columnf100AS1UtpSpeedStatusLocal | read-only | current | Local device card UTP port speed status: 0:10 Base-T 1:100 Base-TX |
| 1.3.6.1.4.1.4756.20.450.40.1.21 | Columnf100AS1UtpDuplexStatusLocal | read-only | current | Local device card UTP port duplex status: 0:Half duplex mode 1:Full duplex mode |
| 1.3.6.1.4.1.4756.20.450.40.1.22 | Columnf100AS1UtpIngressRateLocal | read-write | current | Local device card utp Ingress Rate Limit: 0 = Unlimit input format: 64k(K),99m(M),99 If doesn't input the unit, the default was Mega. Limite Rate : 64K ~ 99M |
| 1.3.6.1.4.1.4756.20.450.40.1.23 | Columnf100AS1UtpEgressRateLocal | read-write | current | Local device card utp Egress Rate Limit: 0 = Unlimit input format: 64k(K),99m(M),99 If doesn't input the unit, the default was Mega. Limite Rate : 64K ~ 99M |
| 1.3.6.1.4.1.4756.20.450.40.1.24 | Columnf100AS1DeviceActiveLocal | read-write | current | Local device card active mode: (It is read-only in remote device.) 0:Disable 1:Enable |
| 1.3.6.1.4.1.4756.20.450.40.1.25 | Columnf100AS1DeviceResetLocal | read-write | current | Force local device card to reset mode: 0:Off 1:Action |
| 1.3.6.1.4.1.4756.20.450.40.1.26 | Columnf100AS1FiberActiveLocal | read-write | current | Local device fiber port active mode: 0:Disable 1:Enable |
| 1.3.6.1.4.1.4756.20.450.40.1.27 | Columnf100AS1UtpActiveLocal | read-write | current | Local device UTP port active mode: 0:Disable 1:Enable |
| 1.3.6.1.4.1.4756.20.450.40.1.28 | Columnf100AS1OamChModeLocal | read-write | current | Local device OAM Channel mode: 0:Disable 1:passive 2:Active |
| 1.3.6.1.4.1.4756.20.450.40.1.29 | Columnf100AS1OamMaxPDUsLocal | read-write | current | Local device OAM max OAMPDU size: 60-1518 Octets |
| 1.3.6.1.4.1.4756.20.450.40.1.30 | Columnf100AS1FiberAlsLocal | read-write | current | Local device card port Auto Laser Shutdown mode: 0:Disable 1:Enable |
| 1.3.6.1.4.1.4756.20.450.40.1.31 | Columnf100AS1PauseFrameLocal | read-write | current | Local device card pause frame mode: 0:Disable 1:Enable |
| 1.3.6.1.4.1.4756.20.450.40.1.32 | Columnf100AS1SendFHRtoALocal | read-write | current | Local device card port send Fiber Hardware Reset to remote: 0:No action 1:Action |
| 1.3.6.1.4.1.4756.20.450.40.1.33 | Columnf100AS1FiberLLFDepPortLocal | read-write | current | Local device card port Link Loss Forwarding depends on port 3 Ethernet Rx link: 0:don't care 1:selected |
| 1.3.6.1.4.1.4756.20.450.40.1.34 | Columnf100AS1UtpLLFDepPortLocal | read-write | current | Local device card port Link Loss Forwarding depends on port Fiber Rx link: 0:don't care 1:selected |
| 1.3.6.1.4.1.4756.20.450.40.1.35 | Columnf100AS1AdvanceFunsLocal | read-write | current | Local device card Switch functions mode: 0:Normal 5:Static 802.1Q VLAN 6:Spanning Tree Protocol 7:802.1Q VLAN Trunk 9:Q in Q VLAN 11:Spanning Tree Protocol and… |
| 1.3.6.1.4.1.4756.20.450.40.1.36 | Columnf100AS1FiberInfoROM1Local | read-only | current | Local device card port INFORemoteOM information 1 valid: 0:Invalid 1:Valid |
| 1.3.6.1.4.1.4756.20.450.40.1.37 | Columnf100AS1FiberInfoROM2Local | read-only | current | Local device card port INFORemoteOM information 2 valid: 0:Invalid 1:Valid(replacing D/D function |
| 1.3.6.1.4.1.4756.20.450.40.1.38 | Columnf100AS1FiberInfoSN1Local | read-only | current | Local device card port 1 NFORemoteOM S/N 1 |
| 1.3.6.1.4.1.4756.20.450.40.1.39 | Columnf100AS1FiberInfoSN2Local | read-only | current | Local device card port 1 INFORemoteOM S/N 2 |
| 1.3.6.1.4.1.4756.20.450.40.1.40 | Columnf100AS1FiberDDLocal | read-only | current | Local device card fiber port Digital Diagnostic function: 0:No 1:Yes |
| 1.3.6.1.4.1.4756.20.450.40.1.41 | Columnf100AS1FiberDDVendorLocal | read-only | current | Local device card fiber port D/D information: Vendor name |
| 1.3.6.1.4.1.4756.20.450.40.1.42 | Columnf100AS1FiberDDPartNoLocal | read-only | current | Local device card fiber port D/D information: Vendor part number |
| 1.3.6.1.4.1.4756.20.450.40.1.43 | Columnf100AS1FiberDDFiberTypeLocal | read-only | current | Local device card fiber port D/D information: Fiber Type |
| 1.3.6.1.4.1.4756.20.450.40.1.44 | Columnf100AS1FiberDDWaveLenLocal | read-only | current | Local device card fiber port D/D information: Wave length |
| 1.3.6.1.4.1.4756.20.450.40.1.45 | Columnf100AS1FiberDDWaveLen2Local | read-only | current | Local device card fiber port D/D information: Wave length 2 |
| 1.3.6.1.4.1.4756.20.450.40.1.46 | Columnf100AS1FiberDDLinkLenLocal | read-only | current | Local device card fiber port D/D information: Link length |
| 1.3.6.1.4.1.4756.20.450.40.1.47 | Columnf100AS1FiberDDLenUnitLocal | read-only | current | Local device card fiber port D/D information: Length Unit |
| 1.3.6.1.4.1.4756.20.450.40.1.48 | Columnf100AS1FiberDDStatusLocal | read-only | current | Local device card fiber port D/D information: Status Support |
| 1.3.6.1.4.1.4756.20.450.40.1.49 | Columnf100AS1FiberDDRxSensLocal | read-only | current | Local device card fiber port D/D information: Rx Sensitivity |
| 1.3.6.1.4.1.4756.20.450.40.1.50 | Columnf100AS1FiberDDTxPWRLocal | read-only | current | Local device card fiber port D/D information: Tx power |
| 1.3.6.1.4.1.4756.20.450.40.1.51 | Columnf100AS1FiberDDRxPWRLocal | read-only | current | Local device card fiber port D/D information: Rx power |
| 1.3.6.1.4.1.4756.20.450.40.1.52 | Columnf100AS1FiberDDTempLocal | read-only | current | Local device card fiber port D/D information: Temperature in degree C |
| 1.3.6.1.4.1.4756.20.450.40.1.53 | Columnf100AS1FiberDDPWRMarginLocal | read-only | current | Local device card fiber port D/D information: Power margin |
| 1.3.6.1.4.1.4756.20.450.40.1.54 | Columnf100AS1FiberDDPWRLossLocal | read-only | current | Local device card fiber port D/D information: Power loss |
| 1.3.6.1.4.1.4756.20.450.40.1.55 | Columnf100AS1ClrRMONCntsLocal | read-write | current | Clear local device card RMON IN/OUT counters: 0:No action 1:Action |
| 1.3.6.1.4.1.4756.20.450.40.1.56 | Columnf100AS1FiberRMONInLocal | read-only | current | Local device card port RMON IN counter. |
| 1.3.6.1.4.1.4756.20.450.40.1.57 | Columnf100AS1FiberRMONOutLocal | read-only | current | Local device card port RMON OUT counter. |
| 1.3.6.1.4.1.4756.20.450.40.1.58 | Columnf100AS1UtpRMONInLocal | read-only | current | Local device card port RMON IN counter. |
| 1.3.6.1.4.1.4756.20.450.40.1.59 | Columnf100AS1UtpRMONOutLocal | read-only | current | Local device card port RMON OUT counter. |
| 1.3.6.1.4.1.4756.20.450.40.1.60 | Columnf100AS1ClrOAMCntsLocal | read-write | current | Clear local device card OAM counters: 0:No action 1:Action |
| 1.3.6.1.4.1.4756.20.450.40.1.61 | Columnf100AS1IpModeLocal | read-write | current | On Rack Ip Mode: 0:Enable 1:Disable |
| 1.3.6.1.4.1.4756.20.450.40.1.62 | Columnf100AS1OamChTxLocal | read-only | current | Local device OAM Channel TX OAMPDU frame count |
| 1.3.6.1.4.1.4756.20.450.40.1.63 | Columnf100AS1OamChRxLocal | read-only | current | Local device OAM Channel RX OAMPDU frame count |
| 1.3.6.1.4.1.4756.20.450.40.1.64 | Columnf100AS1OamInfoChTxLocal | read-only | current | Local device OAM Channel TX Information OAMPDU frame count |
| 1.3.6.1.4.1.4756.20.450.40.1.65 | Columnf100AS1OamInfoChRxLocal | read-only | current | Local device OAM Channel RX Information OAMPDU frame count |
| 1.3.6.1.4.1.4756.20.450.40.1.66 | Columnf100AS1OamEventChTxLocal | read-only | current | Local device OAM Channel TX Event OAMPDU frame count |
| 1.3.6.1.4.1.4756.20.450.40.1.67 | Columnf100AS1OamUniEvtChRxLocal | read-only | current | Local device OAM Channel RX Unique Event OAMPDU frame count |
| 1.3.6.1.4.1.4756.20.450.40.1.68 | Columnf100AS1OamDupEvtChRxLocal | read-only | current | Local device OAM Channel RX Duplicate Event OAMPDU frame count |
| 1.3.6.1.4.1.4756.20.450.40.1.69 | Columnf100AS1OamLbChTxLocal | read-only | current | Local device OAM Channel TX Loopback Control OAMPDU frame count |
| 1.3.6.1.4.1.4756.20.450.40.1.70 | Columnf100AS1OamLbChRxLocal | read-only | current | Local device OAM Channel RX Loopback Control OAMPDU frame count |
| 1.3.6.1.4.1.4756.20.450.40.1.71 | Columnf100AS1OamVarReqChTxLocal | read-only | current | Local device OAM Channel TX Variable Request OAMPDU frame count |
| 1.3.6.1.4.1.4756.20.450.40.1.72 | Columnf100AS1OamVarReqChRxLocal | read-only | current | Local device OAM Channel RX Variable Request OAMPDU frame count |
| 1.3.6.1.4.1.4756.20.450.40.1.73 | Columnf100AS1OamVarRspChTxLocal | read-only | current | Local device OAM Channel TX Variable Response OAMPDU frame count |
| 1.3.6.1.4.1.4756.20.450.40.1.74 | Columnf100AS1OamVarRspChRxLocal | read-only | current | Local device OAM Channel RX Variable Response OAMPDU frame count |
| 1.3.6.1.4.1.4756.20.450.40.1.75 | Columnf100AS1OamOuiChTxLocal | read-only | current | Local device OAM Channel TX OUI OAMPDU frame count |
| 1.3.6.1.4.1.4756.20.450.40.1.76 | Columnf100AS1OamOuiChRxLocal | read-only | current | Local device OAM Channel RX OUI OAMPDU frame count |
| 1.3.6.1.4.1.4756.20.450.40.1.77 | Columnf100AS1OamUnknowChRxLocal | read-only | current | Local device OAM Channel RX Unsupported OAMPDU frame count |
| 1.3.6.1.4.1.4756.20.450.40.1.78 | Columnf100AS1FiberSpeedLocal | read-only | current | Local device Fiber speed : 1:100 |
| 1.3.6.1.4.1.4756.20.450.40.1.79 | Columnf100AS1MacLearningLocal | read-write | current | Local device Mac learning : 0:Disable 1:Enable |
| 1.3.6.1.4.1.4756.20.450.40.1.80 | Columnf100AS1Port1VIDLocal | read-write | current | Local device Port 1 VID : |
| 1.3.6.1.4.1.4756.20.450.40.1.81 | Columnf100AS1Port2VIDLocal | read-write | current | Local device Port 2 VID : |
| 1.3.6.1.4.1.4756.20.450.40.1.82 | Columnf100AS1Port1QinQLocal | read-write | current | Local device Port 1 Q in Q Support : 1:Disable 2:Enable |
| 1.3.6.1.4.1.4756.20.450.40.1.83 | Columnf100AS1Port2QinQLocal | read-write | current | Local device Port 2 Q in Q Support : 1:Disable 2:Enable |
| 1.3.6.1.4.1.4756.20.450.40.1.84 | Columnf100AS1VID1Local | read-write | current | Local device VID 1: |
| 1.3.6.1.4.1.4756.20.450.40.1.85 | Columnf100AS1VID2Local | read-write | current | Local device VID 2: |
| 1.3.6.1.4.1.4756.20.450.40.1.86 | Columnf100AS1VID3Local | read-write | current | Local device VID 3: |
| 1.3.6.1.4.1.4756.20.450.40.1.87 | Columnf100AS1VID4Local | read-write | current | Local device VID 4: |
| 1.3.6.1.4.1.4756.20.450.40.1.88 | Columnf100AS1VID5Local | read-write | current | Local device VID 5: |
| 1.3.6.1.4.1.4756.20.450.40.1.89 | Columnf100AS1VID6Local | read-write | current | Local device VID 6: |
| 1.3.6.1.4.1.4756.20.450.40.1.90 | Columnf100AS1VID7Local | read-write | current | Local device VID 7: |
| 1.3.6.1.4.1.4756.20.450.40.1.91 | Columnf100AS1VID8Local | read-write | current | Local device VID 8: |
| 1.3.6.1.4.1.4756.20.450.40.1.92 | Columnf100AS1VID9Local | read-write | current | Local device VID 9: |
| 1.3.6.1.4.1.4756.20.450.40.1.93 | Columnf100AS1VID10Local | read-write | current | Local device VID 10: |
| 1.3.6.1.4.1.4756.20.450.40.1.94 | Columnf100AS1VID11Local | read-write | current | Local device VID 11: |
| 1.3.6.1.4.1.4756.20.450.40.1.95 | Columnf100AS1VID12Local | read-write | current | Local device VID 12: |
| 1.3.6.1.4.1.4756.20.450.40.1.96 | Columnf100AS1VID13Local | read-write | current | Local device VID 13: |
| 1.3.6.1.4.1.4756.20.450.40.1.97 | Columnf100AS1VID14Local | read-write | current | Local device VID 14: |
| 1.3.6.1.4.1.4756.20.450.40.1.98 | Columnf100AS1VID15Local | read-write | current | Local device VID 15: |
| 1.3.6.1.4.1.4756.20.450.40.1.99 | Columnf100AS1VID16Local | read-write | current | Local device VID 16: |
| 1.3.6.1.4.1.4756.20.450.40.1.100 | Columnf100AS1Port1Member1Local | read-write | current | Local device card port 1 member: 0:Unmodify 1:Untagged 2:Tagged 3:Nonmember |
| 1.3.6.1.4.1.4756.20.450.40.1.101 | Columnf100AS1Port1Member2Local | read-write | current | Local device card port 1 member 2: 0:Unmodify 1:Untagged 2:Tagged 3:Nonmember |
| 1.3.6.1.4.1.4756.20.450.40.1.102 | Columnf100AS1Port1Member3Local | read-write | current | Local device card port 1 member 3: 0:Unmodify 1:Untagged 2:Tagged 3:Nonmember |
| 1.3.6.1.4.1.4756.20.450.40.1.103 | Columnf100AS1Port1Member4Local | read-write | current | Local device card port 1 member 4: 0:Unmodify 1:Untagged 2:Tagged 3:Nonmember |
| 1.3.6.1.4.1.4756.20.450.40.1.104 | Columnf100AS1Port1Member5Local | read-write | current | Local device card port 1 member 5: 0:Unmodify 1:Untagged 2:Tagged 3:Nonmember |
| 1.3.6.1.4.1.4756.20.450.40.1.105 | Columnf100AS1Port1Member6Local | read-write | current | Local device card port 1 member 6: 0:Unmodify 1:Untagged 2:Tagged 3:Nonmember |
| 1.3.6.1.4.1.4756.20.450.40.1.106 | Columnf100AS1Port1Member7Local | read-write | current | Local device card port 1 member 7: 0:Unmodify 1:Untagged 2:Tagged 3:Nonmember |
| 1.3.6.1.4.1.4756.20.450.40.1.107 | Columnf100AS1Port1Member8Local | read-write | current | Local device card port 1 member 8: 0:Unmodify 1:Untagged 2:Tagged 3:Nonmember |
| 1.3.6.1.4.1.4756.20.450.40.1.108 | Columnf100AS1Port1Member9Local | read-write | current | Local device card port 1 member 9: 0:Unmodify 1:Untagged 2:Tagged 3:Nonmember |
| 1.3.6.1.4.1.4756.20.450.40.1.109 | Columnf100AS1Port1Member10Local | read-write | current | Local device card port 1 member 10: 0:Unmodify 1:Untagged 2:Tagged 3:Nonmember |
| 1.3.6.1.4.1.4756.20.450.40.1.110 | Columnf100AS1Port1Member11Local | read-write | current | Local device card port 1 member 11: 0:Unmodify 1:Untagged 2:Tagged 3:Nonmember |
| 1.3.6.1.4.1.4756.20.450.40.1.111 | Columnf100AS1Port1Member12Local | read-write | current | Local device card port 1 member 12: 0:Unmodify 1:Untagged 2:Tagged 3:Nonmember |
| 1.3.6.1.4.1.4756.20.450.40.1.112 | Columnf100AS1Port1Member13Local | read-write | current | Local device card port 1 member 13: 0:Unmodify 1:Untagged 2:Tagged 3:Nonmember |
| 1.3.6.1.4.1.4756.20.450.40.1.113 | Columnf100AS1Port1Member14Local | read-write | current | Local device card port 1 member 14: 0:Unmodify 1:Untagged 2:Tagged 3:Nonmember |
| 1.3.6.1.4.1.4756.20.450.40.1.114 | Columnf100AS1Port1Member15Local | read-write | current | Local device card port 1 member 15: 0:Unmodify 1:Untagged 2:Tagged 3:Nonmember |
| 1.3.6.1.4.1.4756.20.450.40.1.115 | Columnf100AS1Port1Member16Local | read-write | current | Local device card port 1 member 16: 0:Unmodify 1:Untagged 2:Tagged 3:Nonmember |
| 1.3.6.1.4.1.4756.20.450.40.1.116 | Columnf100AS1Port2Member1Local | read-write | current | Local device card port 2 member: 0:Unmodify 1:Untagged 2:Tagged 3:Nonmember |
| 1.3.6.1.4.1.4756.20.450.40.1.117 | Columnf100AS1Port2Member2Local | read-write | current | Local device card port 2 member 2: 0:Unmodify 1:Untagged 2:Tagged 3:Nonmember |
| 1.3.6.1.4.1.4756.20.450.40.1.118 | Columnf100AS1Port2Member3Local | read-write | current | Local device card port 2 member 3: 0:Unmodify 1:Untagged 2:Tagged 3:Nonmember |
| 1.3.6.1.4.1.4756.20.450.40.1.119 | Columnf100AS1Port2Member4Local | read-write | current | Local device card port 2 member 4: 0:Unmodify 1:Untagged 2:Tagged 3:Nonmember |
| 1.3.6.1.4.1.4756.20.450.40.1.120 | Columnf100AS1Port2Member5Local | read-write | current | Local device card port 2 member 5: 0:Unmodify 1:Untagged 2:Tagged 3:Nonmember |
| 1.3.6.1.4.1.4756.20.450.40.1.121 | Columnf100AS1Port2Member6Local | read-write | current | Local device card port 2 member 6: 0:Unmodify 1:Untagged 2:Tagged 3:Nonmember |
| 1.3.6.1.4.1.4756.20.450.40.1.122 | Columnf100AS1Port2Member7Local | read-write | current | Local device card port 2 member 7: 0:Unmodify 1:Untagged 2:Tagged 3:Nonmember |
| 1.3.6.1.4.1.4756.20.450.40.1.123 | Columnf100AS1Port2Member8Local | read-write | current | Local device card port 2 member 8: 0:Unmodify 1:Untagged 2:Tagged 3:Nonmember |
| 1.3.6.1.4.1.4756.20.450.40.1.124 | Columnf100AS1Port2Member9Local | read-write | current | Local device card port 2 member 9: 0:Unmodify 1:Untagged 2:Tagged 3:Nonmember |
| 1.3.6.1.4.1.4756.20.450.40.1.125 | Columnf100AS1Port2Member10Local | read-write | current | Local device card port 2 member 10: 0:Unmodify 1:Untagged 2:Tagged 3:Nonmember |
| 1.3.6.1.4.1.4756.20.450.40.1.126 | Columnf100AS1Port2Member11Local | read-write | current | Local device card port 2 member 11: 0:Unmodify 1:Untagged 2:Tagged 3:Nonmember |
| 1.3.6.1.4.1.4756.20.450.40.1.127 | Columnf100AS1Port2Member12Local | read-write | current | Local device card port 2 member 12: 0:Unmodify 1:Untagged 2:Tagged 3:Nonmember |
| 1.3.6.1.4.1.4756.20.450.40.1.128 | Columnf100AS1Port2Member13Local | read-write | current | Local device card port 2 member 13: 0:Unmodify 1:Untagged 2:Tagged 3:Nonmember |
| 1.3.6.1.4.1.4756.20.450.40.1.129 | Columnf100AS1Port2Member14Local | read-write | current | Local device card port 2 member 14: 0:Unmodify 1:Untagged 2:Tagged 3:Nonmember |
| 1.3.6.1.4.1.4756.20.450.40.1.130 | Columnf100AS1Port2Member15Local | read-write | current | Local device card port 2 member 15: 0:Unmodify 1:Untagged 2:Tagged 3:Nonmember |
| 1.3.6.1.4.1.4756.20.450.40.1.131 | Columnf100AS1Port2Member16Local | read-write | current | Local device card port 2 member 16: 0:Unmodify 1:Untagged 2:Tagged 3:Nonmember |
| 1.3.6.1.4.1.4756.20.450.40.1.132 | Columnf100AS1IpAddressLocal | read-write | current | Local device IP address |
| 1.3.6.1.4.1.4756.20.450.40.1.133 | Columnf100AS1NetMaskLocal | read-write | current | Local device Netmask |
| 1.3.6.1.4.1.4756.20.450.40.1.134 | Columnf100AS1GateWayLocal | read-write | current | Local device Gateway |
| 1.3.6.1.4.1.4756.20.450.40.1.135 | Columnf100AS1SetDefaultLocal | read-write | current | Local device set to default |
| 1.3.6.1.4.1.4756.20.450.40.1.136 | Columnf100AS1ManagementVIDLocal | read-write | current | Local device Management VID : |
| 1.3.6.1.4.1.4756.20.450.40.1.137 | Columnf100AS1TagTypeLocal | read-write | current | Local device Tag Type (HEX) : |
| 1.3.6.1.4.1.4756.20.450.40.1.138 | Columnf100AS1FxLinkAlarmLocal | read-write | current | Local device fiber link alarm 0:Disable 1:Enable |
| 1.3.6.1.4.1.4756.20.450.40.1.139 | Columnf100AS1UtpLinkAlarmLocal | read-write | current | Local device utp link alarm 0:Disable 1:Enable |
| 1.3.6.1.4.1.4756.20.450.40.1.140 | Columnf100AS1PingStatusLocal | read-only | current | Local device icmp ping status Show Ping Status 0: Normal 1: Not Ready 2: 5 packets transmitted, 5 received, 0 packet loss. (Ping OK) 3: 5 packets transmitted, … |
| 1.3.6.1.4.1.4756.20.450.40.1.141 | Columnf100AS1PingIpAddressLocal | read-write | current | Local device ping IP address |
| 1.3.6.1.4.1.4756.20.450.40.1.142 | Columnf100AS1PingStartLocal | read-write | current | Local device ping start 0:Off 1:Action |
| 1.3.6.1.4.1.4756.20.450.40.1.143 | Columnf100AS1RemoteTLPTLocal | read-write | current | Local device Remote TLPT mode : 0:Disalbe 1:Remote |
| 1.3.6.1.4.1.4756.20.450.40.1.144 | Columnf100AS1FxLBTLocal | read-write | current | FRM220-100AS-1A Fiber LoopBack Test: 0: Disalbe 1: Enable 2: Not Support |
| 1.3.6.1.4.1.4756.20.450.40.1.145 | Columnf100AS1UtpLBTLocal | read-write | current | FRM220-100AS-1A UTP LoopBack Test: 0: Disalbe 1: Enable 2: Not Support |
| 1.3.6.1.4.1.4756.20.451 | Nodef100AS1RemoteACards | |||
| 1.3.6.1.4.1.4756.20.451.40 | Tablef100AS1RemoteATable | not-accessible | current | A list of RemoteA 100AS-1 card entries. |
| 1.3.6.1.4.1.4756.20.451.40.1 | Rowf100AS1RemoteAEntry | not-accessible | current | An entry containing management information applicable to a particular RemoteA f100AS-1 card. |
| 1.3.6.1.4.1.4756.20.451.40.1.1 | Columnf100AS1ChassisIndexRemoteA | read-only | current | A unique value for each chassis ID. For CH20, it is the chassis ID. For CH08, it is always 0. |
| 1.3.6.1.4.1.4756.20.451.40.1.2 | Columnf100AS1SlotIndexRemoteA | read-only | current | A unique value for each RemoteA card. It is the slot location number. |
| 1.3.6.1.4.1.4756.20.451.40.1.3 | Columnf100AS1CardHWVerRemoteA | read-only | current | RemoteA device card hardware version x.xxx |
| 1.3.6.1.4.1.4756.20.451.40.1.4 | Columnf100AS1CardFWVerRemoteA | read-only | current | RemoteA device card firmware version x.xxx |
| 1.3.6.1.4.1.4756.20.451.40.1.5 | Columnf100AS1CardCPLDVerRemoteA | read-only | current | RemoteA device card CPLD version x.xxx |
| 1.3.6.1.4.1.4756.20.451.40.1.6 | Columnf100AS1CardFPGAVerRemoteA | read-only | current | RemoteA device card FPGA version x.xxx |
| 1.3.6.1.4.1.4756.20.451.40.1.7 | Columnf100AS1ModelRemoteA | read-only | current | RemoteA 100AS-1 Serial Type |
| 1.3.6.1.4.1.4756.20.451.40.1.8 | Columnf100AS1FiberLinkRemoteA | read-only | current | RemoteA device card fiber port link status: 0:Down 1:Up |
| 1.3.6.1.4.1.4756.20.451.40.1.9 | Columnf100AS1FiberOAMLoopedRemoteA | read-only | current | RemoteA device card fiber port OAM looped: 0:Off 1:on |
| 1.3.6.1.4.1.4756.20.451.40.1.10 | Columnf100AS1FiberLBTestRemoteA | read-write | current | Force remote device card to do fiber port LoopBack testing: 0:Off 1:Action |
| 1.3.6.1.4.1.4756.20.451.40.1.11 | Columnf100AS1FiberOAMRLBStatusRemoteA | read-only | current | RemoteA device card fiber port LoopBack testing status: 0:Off 1:Ok 2:Fail |
| 1.3.6.1.4.1.4756.20.451.40.1.12 | Columnf100AS1FiberRemoPwrAbRemoteA | read-only | current | RemoteA device card fiber port RemoteA Power status: 0:Abnormal 1:OK 2:None |
| 1.3.6.1.4.1.4756.20.451.40.1.13 | Columnf100AS1FiberFEFRemoteA | read-only | current | RemoteA device card fiber port FEF status: 0:Abnormal 1:OFF 2:Detected |
| 1.3.6.1.4.1.4756.20.451.40.1.14 | Columnf100AS1FiberIngressRateRemoteA | read-write | current | RemoteA device card fiber Ingress Rate Limit: 0 = Unlimit input format: 64k(K),99m(M),99 If doesn't input the unit, the default was Mega. Limite Rate : 64K ~ 9… |
| 1.3.6.1.4.1.4756.20.451.40.1.15 | Columnf100AS1FiberEgressRateRemoteA | read-write | current | RemoteA device card fiber Egress Rate Limit: 0 = Unlimit input format: 64k(K),99m(M),99 If doesn't input the unit, the default was Mega. Limite Rate : 64K ~ 99M |
| 1.3.6.1.4.1.4756.20.451.40.1.16 | Columnf100AS1UtpLinkRemoteA | read-only | current | RemoteA device card UTP port link status: 0:Down 1:Up |
| 1.3.6.1.4.1.4756.20.451.40.1.17 | Columnf100AS1UtpNegoRemoteA | read-write | current | RemoteA device card UTP port negotiation status: 0:Manual 1:Auto |
| 1.3.6.1.4.1.4756.20.451.40.1.18 | Columnf100AS1UtpSpeedRemoteA | read-write | current | RemoteA device card UTP port speed setting: 0:10 Base-T 1:100 Base-TX |
| 1.3.6.1.4.1.4756.20.451.40.1.19 | Columnf100AS1UtpDuplexRemoteA | read-write | current | RemoteA device card UTP port duplex setting: 0:Half duplex mode 1:Full duplex mode |
| 1.3.6.1.4.1.4756.20.451.40.1.20 | Columnf100AS1UtpSpeedStatusRemoteA | read-only | current | RemoteA device card UTP port speed status: 0:10 Base-T 1:100 Base-TX |
| 1.3.6.1.4.1.4756.20.451.40.1.21 | Columnf100AS1UtpDuplexStatusRemoteA | read-only | current | RemoteA device card UTP port duplex status: 0:Half duplex mode 1:Full duplex mode |
| 1.3.6.1.4.1.4756.20.451.40.1.22 | Columnf100AS1UtpIngressRateRemoteA | read-write | current | RemoteA device card utp Ingress Rate Limit: 0 = Unlimit input format: 64k(K),99m(M),99 If doesn't input the unit, the default was Mega. Limite Rate : 64K ~ 99M |
| 1.3.6.1.4.1.4756.20.451.40.1.23 | Columnf100AS1UtpEgressRateRemoteA | read-write | current | RemoteA device card utp Egress Rate Limit: 0 = Unlimit input format: 64k(K),99m(M),99 If doesn't input the unit, the default was Mega. Limite Rate : 64K ~ 99M |
| 1.3.6.1.4.1.4756.20.451.40.1.24 | Columnf100AS1DeviceResetRemoteA | read-write | current | Force RemoteA device card to reset mode: 0:Off 1:Action |
| 1.3.6.1.4.1.4756.20.451.40.1.25 | Columnf100AS1UtpActiveRemoteA | read-write | current | RemoteA device UTP port active mode: 0:Disable 1:Enable |
| 1.3.6.1.4.1.4756.20.451.40.1.26 | Columnf100AS1OamChModeRemoteA | read-write | current | RemoteA device OAM Channel mode: 0:Disable 1:passive 2:Active |
| 1.3.6.1.4.1.4756.20.451.40.1.27 | Columnf100AS1OamMaxPDUsRemoteA | read-write | current | RemoteA device OAM max OAMPDU size: 60-1518 Octets |
| 1.3.6.1.4.1.4756.20.451.40.1.28 | Columnf100AS1FiberAlsRemoteA | read-write | current | RemoteA device card port Auto Laser Shutdown mode: 0:Disable 1:Enable |
| 1.3.6.1.4.1.4756.20.451.40.1.29 | Columnf100AS1PauseFrameRemoteA | read-write | current | RemoteA device card pause frame mode: 0:Disable 1:Enable |
| 1.3.6.1.4.1.4756.20.451.40.1.30 | Columnf100AS1FHRModeRemoteA | read-write | current | RemoteA device card FHR Mode: 0:Disable 1:Enable |
| 1.3.6.1.4.1.4756.20.451.40.1.31 | Columnf100AS1FiberLLFDepPortRemoteA | read-write | current | RemoteA device card port Link Loss Forwarding depends on port Ethernet Rx link: 0:don't care 1:selected |
| 1.3.6.1.4.1.4756.20.451.40.1.32 | Columnf100AS1UtpLLFDepPortRemoteA | read-write | current | RemoteA device card port Link Loss Forwarding depends on port Fiber Rx link: 0:don't care 1:selected |
| 1.3.6.1.4.1.4756.20.451.40.1.33 | Columnf100AS1AdvanceFunsRemoteA | read-write | current | RemoteA device card Switch functions mode: 0:Normal 5:Static 802.1Q VLAN 6:Spanning Tree Protocol 7:802.1Q VLAN Trunk 9:Q in Q VLAN 11:Spanning Tree Protocol &… |
| 1.3.6.1.4.1.4756.20.451.40.1.34 | Columnf100AS1FiberInfoROM1RemoteA | read-only | current | RemoteA device card port INFORemoteAOM information 1 valid: 0:Invalid 1:Valid |
| 1.3.6.1.4.1.4756.20.451.40.1.35 | Columnf100AS1FiberInfoROM2RemoteA | read-only | current | RemoteA device card port INFORemoteAOM information 2 valid: 0:Invalid 1:Valid(replacing D/D function |
| 1.3.6.1.4.1.4756.20.451.40.1.36 | Columnf100AS1FiberInfoSN1RemoteA | read-only | current | RemoteA device card port INFORemoteOM S/N 1 |
| 1.3.6.1.4.1.4756.20.451.40.1.37 | Columnf100AS1FiberInfoSN2RemoteA | read-only | current | RemoteA device card port INFORemoteOM S/N 2 |
| 1.3.6.1.4.1.4756.20.451.40.1.38 | Columnf100AS1FiberDDRemoteA | read-only | current | RemoteA device card fiber port Digital Diagnostic function: 0:No 1:Yes |
| 1.3.6.1.4.1.4756.20.451.40.1.39 | Columnf100AS1FiberDDVendorRemoteA | read-only | current | RemoteA device card fiber port D/D information: Vendor name |
| 1.3.6.1.4.1.4756.20.451.40.1.40 | Columnf100AS1FiberDDPartNoRemoteA | read-only | current | RemoteA device card fiber port D/D information: Vendor part number |
| 1.3.6.1.4.1.4756.20.451.40.1.41 | Columnf100AS1FiberDDFiberTypeRemoteA | read-only | current | RemoteA device card fiber port D/D information: Fiber Type |
| 1.3.6.1.4.1.4756.20.451.40.1.42 | Columnf100AS1FiberDDWaveLenRemoteA | read-only | current | RemoteA device card fiber port D/D information: Wave length |
| 1.3.6.1.4.1.4756.20.451.40.1.43 | Columnf100AS1FiberDDWaveLen2RemoteA | read-only | current | RemoteA device card fiber port D/D information: Wave length 2 |
| 1.3.6.1.4.1.4756.20.451.40.1.44 | Columnf100AS1FiberDDLinkLenRemoteA | read-only | current | RemoteA device card fiber port D/D information: Link length |
| 1.3.6.1.4.1.4756.20.451.40.1.45 | Columnf100AS1FiberDDLenUnitRemoteA | read-only | current | RemoteA device card fiber port D/D information: Length Unit |
| 1.3.6.1.4.1.4756.20.451.40.1.46 | Columnf100AS1FiberDDStatusRemoteA | read-only | current | RemoteA device card fiber port D/D information: Status Support |
| 1.3.6.1.4.1.4756.20.451.40.1.47 | Columnf100AS1FiberDDRxSensRemoteA | read-only | current | RemoteA device card fiber port D/D information: Rx Sensitivity |
| 1.3.6.1.4.1.4756.20.451.40.1.48 | Columnf100AS1FiberDDTxPWRRemoteA | read-only | current | RemoteA device card fiber port D/D information: Tx power |
| 1.3.6.1.4.1.4756.20.451.40.1.49 | Columnf100AS1FiberDDRxPWRRemoteA | read-only | current | RemoteA device card fiber port D/D information: Rx power |
| 1.3.6.1.4.1.4756.20.451.40.1.50 | Columnf100AS1FiberDDTempRemoteA | read-only | current | RemoteA device card fiber port D/D information: Temperature in degree C |
| 1.3.6.1.4.1.4756.20.451.40.1.51 | Columnf100AS1FiberDDPWRMarginRemoteA | read-only | current | RemoteA device card fiber port D/D information: Power margin |
| 1.3.6.1.4.1.4756.20.451.40.1.52 | Columnf100AS1FiberDDPWRLossRemoteA | read-only | current | RemoteA device card fiber port D/D information: Power loss |
| 1.3.6.1.4.1.4756.20.451.40.1.53 | Columnf100AS1ClrRMONCntsRemoteA | read-write | current | Clear RemoteA device card RMON IN/OUT counters: 0:No action 1:Action |
| 1.3.6.1.4.1.4756.20.451.40.1.54 | Columnf100AS1FiberRMONInRemoteA | read-only | current | RemoteA device card port RMON IN counter. |
| 1.3.6.1.4.1.4756.20.451.40.1.55 | Columnf100AS1FiberRMONOutRemoteA | read-only | current | RemoteA device card port RMON OUT counter. |
| 1.3.6.1.4.1.4756.20.451.40.1.56 | Columnf100AS1UtpRMONInRemoteA | read-only | current | RemoteA device card port RMON IN counter. |
| 1.3.6.1.4.1.4756.20.451.40.1.57 | Columnf100AS1UtpRMONOutRemoteA | read-only | current | RemoteA device card port RMON OUT counter. |
| 1.3.6.1.4.1.4756.20.451.40.1.58 | Columnf100AS1ClrOAMCntsRemoteA | read-write | current | Clear RemoteA device card OAM counters: 0:No action 1:Action |
| 1.3.6.1.4.1.4756.20.451.40.1.59 | Columnf100AS1IpModeRemoteA | read-write | current | On Rack Ip Mode: 0:Enable 1:Disable |
| 1.3.6.1.4.1.4756.20.451.40.1.60 | Columnf100AS1OamChTxRemoteA | read-only | current | RemoteA device OAM Channel TX OAMPDU frame count |
| 1.3.6.1.4.1.4756.20.451.40.1.61 | Columnf100AS1OamChRxRemoteA | read-only | current | RemoteA device OAM Channel RX OAMPDU frame count |
| 1.3.6.1.4.1.4756.20.451.40.1.62 | Columnf100AS1OamInfoChTxRemoteA | read-only | current | RemoteA device OAM Channel TX Information OAMPDU frame count |
| 1.3.6.1.4.1.4756.20.451.40.1.63 | Columnf100AS1OamInfoChRxRemoteA | read-only | current | RemoteA device OAM Channel RX Information OAMPDU frame count |
| 1.3.6.1.4.1.4756.20.451.40.1.64 | Columnf100AS1OamEventChTxRemoteA | read-only | current | RemoteA device OAM Channel TX Event OAMPDU frame count |
| 1.3.6.1.4.1.4756.20.451.40.1.65 | Columnf100AS1OamUniEvtChRxRemoteA | read-only | current | RemoteA device OAM Channel RX Unique Event OAMPDU frame count |
| 1.3.6.1.4.1.4756.20.451.40.1.66 | Columnf100AS1OamDupEvtChRxRemoteA | read-only | current | RemoteA device OAM Channel RX Duplicate Event OAMPDU frame count |
| 1.3.6.1.4.1.4756.20.451.40.1.67 | Columnf100AS1OamLbChTxRemoteA | read-only | current | RemoteA device OAM Channel TX Loopback Control OAMPDU frame count |
| 1.3.6.1.4.1.4756.20.451.40.1.68 | Columnf100AS1OamLbChRxRemoteA | read-only | current | RemoteA device OAM Channel RX Loopback Control OAMPDU frame count |
| 1.3.6.1.4.1.4756.20.451.40.1.69 | Columnf100AS1OamVarReqChTxRemoteA | read-only | current | RemoteA device OAM Channel TX Variable Request OAMPDU frame count |
| 1.3.6.1.4.1.4756.20.451.40.1.70 | Columnf100AS1OamVarReqChRxRemoteA | read-only | current | RemoteA device OAM Channel RX Variable Request OAMPDU frame count |
| 1.3.6.1.4.1.4756.20.451.40.1.71 | Columnf100AS1OamVarRspChTxRemoteA | read-only | current | RemoteA device OAM Channel TX Variable Response OAMPDU frame count |
| 1.3.6.1.4.1.4756.20.451.40.1.72 | Columnf100AS1OamVarRspChRxRemoteA | read-only | current | RemoteA device OAM Channel RX Variable Response OAMPDU frame count |
| 1.3.6.1.4.1.4756.20.451.40.1.73 | Columnf100AS1OamOuiChTxRemoteA | read-only | current | RemoteA device OAM Channel TX OUI OAMPDU frame count |
| 1.3.6.1.4.1.4756.20.451.40.1.74 | Columnf100AS1OamOuiChRxRemoteA | read-only | current | RemoteA device OAM Channel RX OUI OAMPDU frame count |
| 1.3.6.1.4.1.4756.20.451.40.1.75 | Columnf100AS1OamUnknowChRxRemoteA | read-only | current | RemoteA device OAM Channel RX Unsupported OAMPDU frame count |
| 1.3.6.1.4.1.4756.20.451.40.1.76 | Columnf100AS1FiberSpeedRemoteA | read-only | current | RemoteA device Fiber speed : 1:100 |
| 1.3.6.1.4.1.4756.20.451.40.1.77 | Columnf100AS1MacLearningRemoteA | read-write | current | RemoteA device Mac learning : 0:Disable 1:Enable |
| 1.3.6.1.4.1.4756.20.451.40.1.78 | Columnf100AS1Port1VIDRemoteA | read-write | current | RemoteA device Port 1 VID : |
| 1.3.6.1.4.1.4756.20.451.40.1.79 | Columnf100AS1Port2VIDRemoteA | read-write | current | RemoteA device Port 2 VID : |
| 1.3.6.1.4.1.4756.20.451.40.1.80 | Columnf100AS1Port1QinQRemoteA | read-write | current | RemoteA device Port 1 Q in Q Support : 1:Disable 2:Enable |
| 1.3.6.1.4.1.4756.20.451.40.1.81 | Columnf100AS1Port2QinQRemoteA | read-write | current | RemoteA device Port 2 Q in Q Support : 1:Disable 2:Enable |
| 1.3.6.1.4.1.4756.20.451.40.1.82 | Columnf100AS1VID1RemoteA | read-write | current | RemoteA device VID 1: |
| 1.3.6.1.4.1.4756.20.451.40.1.83 | Columnf100AS1VID2RemoteA | read-write | current | RemoteA device VID 2: |
| 1.3.6.1.4.1.4756.20.451.40.1.84 | Columnf100AS1VID3RemoteA | read-write | current | RemoteA device VID 3: |
| 1.3.6.1.4.1.4756.20.451.40.1.85 | Columnf100AS1VID4RemoteA | read-write | current | RemoteA device VID 4: |
| 1.3.6.1.4.1.4756.20.451.40.1.86 | Columnf100AS1VID5RemoteA | read-write | current | RemoteA device VID 5: |
| 1.3.6.1.4.1.4756.20.451.40.1.87 | Columnf100AS1VID6RemoteA | read-write | current | RemoteA device VID 6: |
| 1.3.6.1.4.1.4756.20.451.40.1.88 | Columnf100AS1VID7RemoteA | read-write | current | RemoteA device VID 7: |
| 1.3.6.1.4.1.4756.20.451.40.1.89 | Columnf100AS1VID8RemoteA | read-write | current | RemoteA device VID 8: |
| 1.3.6.1.4.1.4756.20.451.40.1.90 | Columnf100AS1VID9RemoteA | read-write | current | RemoteA device VID 9: |
| 1.3.6.1.4.1.4756.20.451.40.1.91 | Columnf100AS1VID10RemoteA | read-write | current | RemoteA device VID 10: |
| 1.3.6.1.4.1.4756.20.451.40.1.92 | Columnf100AS1VID11RemoteA | read-write | current | RemoteA device VID 11: |
| 1.3.6.1.4.1.4756.20.451.40.1.93 | Columnf100AS1VID12RemoteA | read-write | current | RemoteA device VID 12: |
| 1.3.6.1.4.1.4756.20.451.40.1.94 | Columnf100AS1VID13RemoteA | read-write | current | RemoteA device VID 13: |
| 1.3.6.1.4.1.4756.20.451.40.1.95 | Columnf100AS1VID14RemoteA | read-write | current | RemoteA device VID 14: |
| 1.3.6.1.4.1.4756.20.451.40.1.96 | Columnf100AS1VID15RemoteA | read-write | current | RemoteA device VID 15: |
| 1.3.6.1.4.1.4756.20.451.40.1.97 | Columnf100AS1VID16RemoteA | read-write | current | RemoteA device VID 16: |
| 1.3.6.1.4.1.4756.20.451.40.1.98 | Columnf100AS1Port1Member1RemoteA | read-write | current | RemoteA device card port 1 member: 0:Unmodify 1:Untagged 2:Tagged 3:Nonmember |
| 1.3.6.1.4.1.4756.20.451.40.1.99 | Columnf100AS1Port1Member2RemoteA | read-write | current | RemoteA device card port 1 member 2: 0:Unmodify 1:Untagged 2:Tagged 3:Nonmember |
| 1.3.6.1.4.1.4756.20.451.40.1.100 | Columnf100AS1Port1Member3RemoteA | read-write | current | RemoteA device card port 1 member 3: 0:Unmodify 1:Untagged 2:Tagged 3:Nonmember |
| 1.3.6.1.4.1.4756.20.451.40.1.101 | Columnf100AS1Port1Member4RemoteA | read-write | current | RemoteA device card port 1 member 4: 0:Unmodify 1:Untagged 2:Tagged 3:Nonmember |
| 1.3.6.1.4.1.4756.20.451.40.1.102 | Columnf100AS1Port1Member5RemoteA | read-write | current | RemoteA device card port 1 member 5: 0:Unmodify 1:Untagged 2:Tagged 3:Nonmember |
| 1.3.6.1.4.1.4756.20.451.40.1.103 | Columnf100AS1Port1Member6RemoteA | read-write | current | RemoteA device card port 1 member 6: 0:Unmodify 1:Untagged 2:Tagged 3:Nonmember |
| 1.3.6.1.4.1.4756.20.451.40.1.104 | Columnf100AS1Port1Member7RemoteA | read-write | current | RemoteA device card port 1 member 7: 0:Unmodify 1:Untagged 2:Tagged 3:Nonmember |
| 1.3.6.1.4.1.4756.20.451.40.1.105 | Columnf100AS1Port1Member8RemoteA | read-write | current | RemoteA device card port 1 member 8: 0:Unmodify 1:Untagged 2:Tagged 3:Nonmember |
| 1.3.6.1.4.1.4756.20.451.40.1.106 | Columnf100AS1Port1Member9RemoteA | read-write | current | RemoteA device card port 1 member 9: 0:Unmodify 1:Untagged 2:Tagged 3:Nonmember |
| 1.3.6.1.4.1.4756.20.451.40.1.107 | Columnf100AS1Port1Member10RemoteA | read-write | current | RemoteA device card port 1 member 10: 0:Unmodify 1:Untagged 2:Tagged 3:Nonmember |
| 1.3.6.1.4.1.4756.20.451.40.1.108 | Columnf100AS1Port1Member11RemoteA | read-write | current | RemoteA device card port 1 member 11: 0:Unmodify 1:Untagged 2:Tagged 3:Nonmember |
| 1.3.6.1.4.1.4756.20.451.40.1.109 | Columnf100AS1Port1Member12RemoteA | read-write | current | RemoteA device card port 1 member 12: 0:Unmodify 1:Untagged 2:Tagged 3:Nonmember |
| 1.3.6.1.4.1.4756.20.451.40.1.110 | Columnf100AS1Port1Member13RemoteA | read-write | current | RemoteA device card port 1 member 13: 0:Unmodify 1:Untagged 2:Tagged 3:Nonmember |
| 1.3.6.1.4.1.4756.20.451.40.1.111 | Columnf100AS1Port1Member14RemoteA | read-write | current | RemoteA device card port 1 member 14: 0:Unmodify 1:Untagged 2:Tagged 3:Nonmember |
| 1.3.6.1.4.1.4756.20.451.40.1.112 | Columnf100AS1Port1Member15RemoteA | read-write | current | RemoteA device card port 1 member 15: 0:Unmodify 1:Untagged 2:Tagged 3:Nonmember |
| 1.3.6.1.4.1.4756.20.451.40.1.113 | Columnf100AS1Port1Member16RemoteA | read-write | current | RemoteA device card port 1 member 16: 0:Unmodify 1:Untagged 2:Tagged 3:Nonmember |
| 1.3.6.1.4.1.4756.20.451.40.1.114 | Columnf100AS1Port2Member1RemoteA | read-write | current | RemoteA device card port 2 member: 0:Unmodify 1:Untagged 2:Tagged 3:Nonmember |
| 1.3.6.1.4.1.4756.20.451.40.1.115 | Columnf100AS1Port2Member2RemoteA | read-write | current | RemoteA device card port 2 member 2: 0:Unmodify 1:Untagged 2:Tagged 3:Nonmember |
| 1.3.6.1.4.1.4756.20.451.40.1.116 | Columnf100AS1Port2Member3RemoteA | read-write | current | RemoteA device card port 2 member 3: 0:Unmodify 1:Untagged 2:Tagged 3:Nonmember |
| 1.3.6.1.4.1.4756.20.451.40.1.117 | Columnf100AS1Port2Member4RemoteA | read-write | current | RemoteA device card port 2 member 4: 0:Unmodify 1:Untagged 2:Tagged 3:Nonmember |
| 1.3.6.1.4.1.4756.20.451.40.1.118 | Columnf100AS1Port2Member5RemoteA | read-write | current | RemoteA device card port 2 member 5: 0:Unmodify 1:Untagged 2:Tagged 3:Nonmember |
| 1.3.6.1.4.1.4756.20.451.40.1.119 | Columnf100AS1Port2Member6RemoteA | read-write | current | RemoteA device card port 2 member 6: 0:Unmodify 1:Untagged 2:Tagged 3:Nonmember |
| 1.3.6.1.4.1.4756.20.451.40.1.120 | Columnf100AS1Port2Member7RemoteA | read-write | current | RemoteA device card port 2 member 7: 0:Unmodify 1:Untagged 2:Tagged 3:Nonmember |
| 1.3.6.1.4.1.4756.20.451.40.1.121 | Columnf100AS1Port2Member8RemoteA | read-write | current | RemoteA device card port 2 member 8: 0:Unmodify 1:Untagged 2:Tagged 3:Nonmember |
| 1.3.6.1.4.1.4756.20.451.40.1.122 | Columnf100AS1Port2Member9RemoteA | read-write | current | RemoteA device card port 2 member 9: 0:Unmodify 1:Untagged 2:Tagged 3:Nonmember |
| 1.3.6.1.4.1.4756.20.451.40.1.123 | Columnf100AS1Port2Member10RemoteA | read-write | current | RemoteA device card port 2 member 10: 0:Unmodify 1:Untagged 2:Tagged 3:Nonmember |
| 1.3.6.1.4.1.4756.20.451.40.1.124 | Columnf100AS1Port2Member11RemoteA | read-write | current | RemoteA device card port 2 member 11: 0:Unmodify 1:Untagged 2:Tagged 3:Nonmember |
| 1.3.6.1.4.1.4756.20.451.40.1.125 | Columnf100AS1Port2Member12RemoteA | read-write | current | RemoteA device card port 2 member 12: 0:Unmodify 1:Untagged 2:Tagged 3:Nonmember |
| 1.3.6.1.4.1.4756.20.451.40.1.126 | Columnf100AS1Port2Member13RemoteA | read-write | current | RemoteA device card port 2 member 13: 0:Unmodify 1:Untagged 2:Tagged 3:Nonmember |
| 1.3.6.1.4.1.4756.20.451.40.1.127 | Columnf100AS1Port2Member14RemoteA | read-write | current | RemoteA device card port 2 member 14: 0:Unmodify 1:Untagged 2:Tagged 3:Nonmember |
| 1.3.6.1.4.1.4756.20.451.40.1.128 | Columnf100AS1Port2Member15RemoteA | read-write | current | RemoteA device card port 2 member 15: 0:Unmodify 1:Untagged 2:Tagged 3:Nonmember |
| 1.3.6.1.4.1.4756.20.451.40.1.129 | Columnf100AS1Port2Member16RemoteA | read-write | current | RemoteA device card port 2 member 16: 0:Unmodify 1:Untagged 2:Tagged 3:Nonmember |
| 1.3.6.1.4.1.4756.20.451.40.1.130 | Columnf100AS1IpAddressRemoteA | read-write | current | RemoteA device IP address |
| 1.3.6.1.4.1.4756.20.451.40.1.131 | Columnf100AS1NetMaskRemoteA | read-write | current | RemoteA device Netmask |
| 1.3.6.1.4.1.4756.20.451.40.1.132 | Columnf100AS1GateWayRemoteA | read-write | current | RemoteA device Gateway |
| 1.3.6.1.4.1.4756.20.451.40.1.133 | Columnf100AS1SetDefaultRemoteA | read-write | current | RemoteA device set to default |
| 1.3.6.1.4.1.4756.20.451.40.1.134 | Columnf100AS1ManagementVIDRemoteA | read-write | current | RemoteA device Management VID : |
| 1.3.6.1.4.1.4756.20.451.40.1.135 | Columnf100AS1TagTypeRemoteA | read-write | current | RemoteA device Tag Type (HEX) : |
| 1.3.6.1.4.1.4756.20.451.40.1.136 | Columnf100AS1FxLinkAlarmRemoteA | read-write | current | RemoteA device fiber link alarm 0:Disable 1:Enable |
| 1.3.6.1.4.1.4756.20.451.40.1.137 | Columnf100AS1UtpLinkAlarmRemoteA | read-write | current | RemoteA device utp link alarm 0:Disable 1:Enable |
| 1.3.6.1.4.1.4756.20.451.40.1.138 | Columnf100AS1RemoteTLPTRemoteA | read-write | current | RemoteA device Remote TLPT mode : 0:Disalbe 1:Remote |
| 1.3.6.1.4.1.4756.20.452 | Nodef100AS1RemoteBCards | |||
| 1.3.6.1.4.1.4756.20.452.40 | Tablef100AS1RemoteBTable | not-accessible | current | A list of RemoteB 100AS-1 card entries. |
| 1.3.6.1.4.1.4756.20.452.40.1 | Rowf100AS1RemoteBEntry | not-accessible | current | An entry containing management information applicable to a particular RemoteB f100AS-1 card. |
| 1.3.6.1.4.1.4756.20.452.40.1.1 | Columnf100AS1ChassisIndexRemoteB | read-only | current | A unique value for each chassis ID. For CH20, it is the chassis ID. For CH08, it is always 0. |
| 1.3.6.1.4.1.4756.20.452.40.1.2 | Columnf100AS1SlotIndexRemoteB | read-only | current | A unique value for each RemoteB card. It is the slot location number. |
| 1.3.6.1.4.1.4756.20.452.40.1.3 | Columnf100AS1CardHWVerRemoteB | read-only | current | RemoteB device card hardware version x.xxx |
| 1.3.6.1.4.1.4756.20.452.40.1.4 | Columnf100AS1CardFWVerRemoteB | read-only | current | RemoteB device card firmware version x.xxx |
| 1.3.6.1.4.1.4756.20.452.40.1.5 | Columnf100AS1CardCPLDVerRemoteB | read-only | current | RemoteB device card CPLD version x.xxx |
| 1.3.6.1.4.1.4756.20.452.40.1.6 | Columnf100AS1CardFPGAVerRemoteB | read-only | current | RemoteB device card FPGA version x.xxx |
| 1.3.6.1.4.1.4756.20.452.40.1.7 | Columnf100AS1ModelRemoteB | read-only | current | RemoteB 100AS-1 Serial Type |
| 1.3.6.1.4.1.4756.20.452.40.1.8 | Columnf100AS1FiberLinkRemoteB | read-only | current | RemoteB device card fiber port link status: 0:Down 1:Up |
| 1.3.6.1.4.1.4756.20.452.40.1.9 | Columnf100AS1FiberOAMLoopedRemoteB | read-only | current | RemoteB device card fiber port OAM looped: 0:Off 1:on |
| 1.3.6.1.4.1.4756.20.452.40.1.10 | Columnf100AS1FiberLBTestRemoteB | read-write | current | Force remote device card to do fiber port LoopBack testing: 0:Off 1:Action |
| 1.3.6.1.4.1.4756.20.452.40.1.11 | Columnf100AS1FiberOAMRLBStatusRemoteB | read-only | current | RemoteB device card fiber port LoopBack testing status: 0:Off 1:Ok 2:Fail |
| 1.3.6.1.4.1.4756.20.452.40.1.12 | Columnf100AS1FiberRemoPwrAbRemoteB | read-only | current | RemoteB device card fiber port RemoteB Power status: 0:Abnormal 1:OK 2:None |
| 1.3.6.1.4.1.4756.20.452.40.1.13 | Columnf100AS1FiberFEFRemoteB | read-only | current | RemoteB device card fiber port FEF status: 0:Abnormal 1:OFF 2:Detected |
| 1.3.6.1.4.1.4756.20.452.40.1.14 | Columnf100AS1FiberIngressRateRemoteB | read-write | current | RemoteB device card fiber Ingress Rate Limit: 0 = Unlimit input format: 64k(K),99m(M),99 If doesn't input the unit, the default was Mega. Limite Rate : 64K ~ 9… |
| 1.3.6.1.4.1.4756.20.452.40.1.15 | Columnf100AS1FiberEgressRateRemoteB | read-write | current | RemoteB device card fiber Egress Rate Limit: 0 = Unlimit input format: 64k(K),99m(M),99 If doesn't input the unit, the default was Mega. Limite Rate : 64K ~ 99M |
| 1.3.6.1.4.1.4756.20.452.40.1.16 | Columnf100AS1UtpLinkRemoteB | read-only | current | RemoteB device card UTP port link status: 0:Down 1:Up |
| 1.3.6.1.4.1.4756.20.452.40.1.17 | Columnf100AS1UtpNegoRemoteB | read-write | current | RemoteB device card UTP port negotiation status: 0:Manual 1:Auto |
| 1.3.6.1.4.1.4756.20.452.40.1.18 | Columnf100AS1UtpSpeedRemoteB | read-write | current | RemoteB device card UTP port speed setting: 0:10 Base-T 1:100 Base-TX |
| 1.3.6.1.4.1.4756.20.452.40.1.19 | Columnf100AS1UtpDuplexRemoteB | read-write | current | RemoteB device card UTP port duplex setting: 0:Half duplex mode 1:Full duplex mode |
| 1.3.6.1.4.1.4756.20.452.40.1.20 | Columnf100AS1UtpSpeedStatusRemoteB | read-only | current | RemoteB device card UTP port speed status: 0:10 Base-T 1:100 Base-TX |
| 1.3.6.1.4.1.4756.20.452.40.1.21 | Columnf100AS1UtpDuplexStatusRemoteB | read-only | current | RemoteB device card UTP port duplex status: 0:Half duplex mode 1:Full duplex mode |
| 1.3.6.1.4.1.4756.20.452.40.1.22 | Columnf100AS1UtpIngressRateRemoteB | read-write | current | RemoteB device card utp Ingress Rate Limit: 0 = Unlimit input format: 64k(K),99m(M),99 If doesn't input the unit, the default was Mega. Limite Rate : 64K ~ 99M |
| 1.3.6.1.4.1.4756.20.452.40.1.23 | Columnf100AS1UtpEgressRateRemoteB | read-write | current | RemoteB device card utp Egress Rate Limit: 0 = Unlimit input format: 64k(K),99m(M),99 If doesn't input the unit, the default was Mega. Limite Rate : 64K ~ 99M |
| 1.3.6.1.4.1.4756.20.452.40.1.24 | Columnf100AS1DeviceResetRemoteB | read-write | current | Force RemoteB device card to reset mode: 0:Off 1:Action |
| 1.3.6.1.4.1.4756.20.452.40.1.25 | Columnf100AS1UtpActiveRemoteB | read-write | current | RemoteB device UTP port active mode: 0:Disable 1:Enable |
| 1.3.6.1.4.1.4756.20.452.40.1.26 | Columnf100AS1OamChModeRemoteB | read-write | current | RemoteB device OAM Channel mode: 0:Disable 1:passive 2:Active |
| 1.3.6.1.4.1.4756.20.452.40.1.27 | Columnf100AS1OamMaxPDUsRemoteB | read-write | current | RemoteB device OAM max OAMPDU size: 60-1518 Octets |
| 1.3.6.1.4.1.4756.20.452.40.1.28 | Columnf100AS1FiberAlsRemoteB | read-write | current | RemoteB device card port Auto Laser Shutdown mode: 0:Disable 1:Enable |
| 1.3.6.1.4.1.4756.20.452.40.1.29 | Columnf100AS1PauseFrameRemoteB | read-write | current | RemoteB device card pause frame mode: 0:Disable 1:Enable |
| 1.3.6.1.4.1.4756.20.452.40.1.30 | Columnf100AS1FHRModeRemoteB | read-write | current | RemoteB device card FHR Mode: 0:Disable 1:Enable |
| 1.3.6.1.4.1.4756.20.452.40.1.31 | Columnf100AS1FiberLLFDepPortRemoteB | read-write | current | RemoteB device card port Link Loss Forwarding depends on port Ethernet Rx link: 0:don't care 1:selected |
| 1.3.6.1.4.1.4756.20.452.40.1.32 | Columnf100AS1UtpLLFDepPortRemoteB | read-write | current | RemoteB device card port Link Loss Forwarding depends on port Fiber Rx link: 0:don't care 1:selected |
| 1.3.6.1.4.1.4756.20.452.40.1.33 | Columnf100AS1AdvanceFunsRemoteB | read-write | current | RemoteB device card Switch functions mode: 0:Normal 5:Static 802.1Q VLAN 6:Spanning Tree Protocol 7:802.1Q VLAN Trunk 9:Q in Q VLAN 11:Spanning Tree Protocol &… |
| 1.3.6.1.4.1.4756.20.452.40.1.34 | Columnf100AS1FiberInfoROM1RemoteB | read-only | current | RemoteB device card port INFORemoteBOM information 1 valid: 0:Invalid 1:Valid |
| 1.3.6.1.4.1.4756.20.452.40.1.35 | Columnf100AS1FiberInfoROM2RemoteB | read-only | current | RemoteB device card port INFORemoteBOM information 2 valid: 0:Invalid 1:Valid(replacing D/D function |
| 1.3.6.1.4.1.4756.20.452.40.1.36 | Columnf100AS1FiberInfoSN1RemoteB | read-only | current | RemoteB device card port INFORemoteOM S/N 1 |
| 1.3.6.1.4.1.4756.20.452.40.1.37 | Columnf100AS1FiberInfoSN2RemoteB | read-only | current | RemoteB device card port INFORemoteOM S/N 2 |
| 1.3.6.1.4.1.4756.20.452.40.1.38 | Columnf100AS1FiberDDRemoteB | read-only | current | RemoteB device card fiber port Digital Diagnostic function: 0:No 1:Yes |
| 1.3.6.1.4.1.4756.20.452.40.1.39 | Columnf100AS1FiberDDVendorRemoteB | read-only | current | RemoteB device card fiber port D/D information: Vendor name |
| 1.3.6.1.4.1.4756.20.452.40.1.40 | Columnf100AS1FiberDDPartNoRemoteB | read-only | current | RemoteB device card fiber port D/D information: Vendor part number |
| 1.3.6.1.4.1.4756.20.452.40.1.41 | Columnf100AS1FiberDDFiberTypeRemoteB | read-only | current | RemoteB device card fiber port D/D information: Fiber Type |
| 1.3.6.1.4.1.4756.20.452.40.1.42 | Columnf100AS1FiberDDWaveLenRemoteB | read-only | current | RemoteB device card fiber port D/D information: Wave length |
| 1.3.6.1.4.1.4756.20.452.40.1.43 | Columnf100AS1FiberDDWaveLen2RemoteB | read-only | current | RemoteB device card fiber port D/D information: Wave length 2 |
| 1.3.6.1.4.1.4756.20.452.40.1.44 | Columnf100AS1FiberDDLinkLenRemoteB | read-only | current | RemoteB device card fiber port D/D information: Link length |
| 1.3.6.1.4.1.4756.20.452.40.1.45 | Columnf100AS1FiberDDLenUnitRemoteB | read-only | current | RemoteB device card fiber port D/D information: Length Unit |
| 1.3.6.1.4.1.4756.20.452.40.1.46 | Columnf100AS1FiberDDStatusRemoteB | read-only | current | RemoteB device card fiber port D/D information: Status Support |
| 1.3.6.1.4.1.4756.20.452.40.1.47 | Columnf100AS1FiberDDRxSensRemoteB | read-only | current | RemoteB device card fiber port D/D information: Rx Sensitivity |
| 1.3.6.1.4.1.4756.20.452.40.1.48 | Columnf100AS1FiberDDTxPWRRemoteB | read-only | current | RemoteB device card fiber port D/D information: Tx power |
| 1.3.6.1.4.1.4756.20.452.40.1.49 | Columnf100AS1FiberDDRxPWRRemoteB | read-only | current | RemoteB device card fiber port D/D information: Rx power |
| 1.3.6.1.4.1.4756.20.452.40.1.50 | Columnf100AS1FiberDDTempRemoteB | read-only | current | RemoteB device card fiber port D/D information: Temperature in degree C |
| 1.3.6.1.4.1.4756.20.452.40.1.51 | Columnf100AS1FiberDDPWRMarginRemoteB | read-only | current | RemoteB device card fiber port D/D information: Power margin |
| 1.3.6.1.4.1.4756.20.452.40.1.52 | Columnf100AS1FiberDDPWRLossRemoteB | read-only | current | RemoteB device card fiber port D/D information: Power loss |
| 1.3.6.1.4.1.4756.20.452.40.1.53 | Columnf100AS1ClrRMONCntsRemoteB | read-write | current | Clear RemoteB device card RMON IN/OUT counters: 0:No action 1:Action |
| 1.3.6.1.4.1.4756.20.452.40.1.54 | Columnf100AS1FiberRMONInRemoteB | read-only | current | RemoteB device card port RMON IN counter. |
| 1.3.6.1.4.1.4756.20.452.40.1.55 | Columnf100AS1FiberRMONOutRemoteB | read-only | current | RemoteB device card port RMON OUT counter. |
| 1.3.6.1.4.1.4756.20.452.40.1.56 | Columnf100AS1UtpRMONInRemoteB | read-only | current | RemoteB device card port RMON IN counter. |
| 1.3.6.1.4.1.4756.20.452.40.1.57 | Columnf100AS1UtpRMONOutRemoteB | read-only | current | RemoteB device card port RMON OUT counter. |
| 1.3.6.1.4.1.4756.20.452.40.1.58 | Columnf100AS1ClrOAMCntsRemoteB | read-write | current | Clear RemoteB device card OAM counters: 0:No action 1:Action |
| 1.3.6.1.4.1.4756.20.452.40.1.59 | Columnf100AS1IpModeRemoteB | read-write | current | On Rack Ip Mode: 0:Enable 1:Disable |
| 1.3.6.1.4.1.4756.20.452.40.1.60 | Columnf100AS1OamChTxRemoteB | read-only | current | RemoteB device OAM Channel TX OAMPDU frame count |
| 1.3.6.1.4.1.4756.20.452.40.1.61 | Columnf100AS1OamChRxRemoteB | read-only | current | RemoteB device OAM Channel RX OAMPDU frame count |
| 1.3.6.1.4.1.4756.20.452.40.1.62 | Columnf100AS1OamInfoChTxRemoteB | read-only | current | RemoteB device OAM Channel TX Information OAMPDU frame count |
| 1.3.6.1.4.1.4756.20.452.40.1.63 | Columnf100AS1OamInfoChRxRemoteB | read-only | current | RemoteB device OAM Channel RX Information OAMPDU frame count |
| 1.3.6.1.4.1.4756.20.452.40.1.64 | Columnf100AS1OamEventChTxRemoteB | read-only | current | RemoteB device OAM Channel TX Event OAMPDU frame count |
| 1.3.6.1.4.1.4756.20.452.40.1.65 | Columnf100AS1OamUniEvtChRxRemoteB | read-only | current | RemoteB device OAM Channel RX Unique Event OAMPDU frame count |
| 1.3.6.1.4.1.4756.20.452.40.1.66 | Columnf100AS1OamDupEvtChRxRemoteB | read-only | current | RemoteB device OAM Channel RX Duplicate Event OAMPDU frame count |
| 1.3.6.1.4.1.4756.20.452.40.1.67 | Columnf100AS1OamLbChTxRemoteB | read-only | current | RemoteB device OAM Channel TX Loopback Control OAMPDU frame count |
| 1.3.6.1.4.1.4756.20.452.40.1.68 | Columnf100AS1OamLbChRxRemoteB | read-only | current | RemoteB device OAM Channel RX Loopback Control OAMPDU frame count |
| 1.3.6.1.4.1.4756.20.452.40.1.69 | Columnf100AS1OamVarReqChTxRemoteB | read-only | current | RemoteB device OAM Channel TX Variable Request OAMPDU frame count |
| 1.3.6.1.4.1.4756.20.452.40.1.70 | Columnf100AS1OamVarReqChRxRemoteB | read-only | current | RemoteB device OAM Channel RX Variable Request OAMPDU frame count |
| 1.3.6.1.4.1.4756.20.452.40.1.71 | Columnf100AS1OamVarRspChTxRemoteB | read-only | current | RemoteB device OAM Channel TX Variable Response OAMPDU frame count |
| 1.3.6.1.4.1.4756.20.452.40.1.72 | Columnf100AS1OamVarRspChRxRemoteB | read-only | current | RemoteB device OAM Channel RX Variable Response OAMPDU frame count |
| 1.3.6.1.4.1.4756.20.452.40.1.73 | Columnf100AS1OamOuiChTxRemoteB | read-only | current | RemoteB device OAM Channel TX OUI OAMPDU frame count |
| 1.3.6.1.4.1.4756.20.452.40.1.74 | Columnf100AS1OamOuiChRxRemoteB | read-only | current | RemoteB device OAM Channel RX OUI OAMPDU frame count |
| 1.3.6.1.4.1.4756.20.452.40.1.75 | Columnf100AS1OamUnknowChRxRemoteB | read-only | current | RemoteB device OAM Channel RX Unsupported OAMPDU frame count |
| 1.3.6.1.4.1.4756.20.452.40.1.76 | Columnf100AS1FiberSpeedRemoteB | read-only | current | RemoteB device Fiber speed : 1:100 |
| 1.3.6.1.4.1.4756.20.452.40.1.77 | Columnf100AS1MacLearningRemoteB | read-write | current | RemoteB device Mac learning : 0:Disable 1:Enable |
| 1.3.6.1.4.1.4756.20.452.40.1.78 | Columnf100AS1Port1VIDRemoteB | read-write | current | RemoteB device Port 1 VID : |
| 1.3.6.1.4.1.4756.20.452.40.1.79 | Columnf100AS1Port2VIDRemoteB | read-write | current | RemoteB device Port 2 VID : |
| 1.3.6.1.4.1.4756.20.452.40.1.80 | Columnf100AS1Port1QinQRemoteB | read-write | current | RemoteB device Port 1 Q in Q Support : 1:Disable 2:Enable |
| 1.3.6.1.4.1.4756.20.452.40.1.81 | Columnf100AS1Port2QinQRemoteB | read-write | current | RemoteB device Port 2 Q in Q Support : 1:Disable 2:Enable |
| 1.3.6.1.4.1.4756.20.452.40.1.82 | Columnf100AS1VID1RemoteB | read-write | current | RemoteB device VID 1: |
| 1.3.6.1.4.1.4756.20.452.40.1.83 | Columnf100AS1VID2RemoteB | read-write | current | RemoteB device VID 2: |
| 1.3.6.1.4.1.4756.20.452.40.1.84 | Columnf100AS1VID3RemoteB | read-write | current | RemoteB device VID 3: |
| 1.3.6.1.4.1.4756.20.452.40.1.85 | Columnf100AS1VID4RemoteB | read-write | current | RemoteB device VID 4: |
| 1.3.6.1.4.1.4756.20.452.40.1.86 | Columnf100AS1VID5RemoteB | read-write | current | RemoteB device VID 5: |
| 1.3.6.1.4.1.4756.20.452.40.1.87 | Columnf100AS1VID6RemoteB | read-write | current | RemoteB device VID 6: |
| 1.3.6.1.4.1.4756.20.452.40.1.88 | Columnf100AS1VID7RemoteB | read-write | current | RemoteB device VID 7: |
| 1.3.6.1.4.1.4756.20.452.40.1.89 | Columnf100AS1VID8RemoteB | read-write | current | RemoteB device VID 8: |
| 1.3.6.1.4.1.4756.20.452.40.1.90 | Columnf100AS1VID9RemoteB | read-write | current | RemoteB device VID 9: |
| 1.3.6.1.4.1.4756.20.452.40.1.91 | Columnf100AS1VID10RemoteB | read-write | current | RemoteB device VID 10: |
| 1.3.6.1.4.1.4756.20.452.40.1.92 | Columnf100AS1VID11RemoteB | read-write | current | RemoteB device VID 11: |
| 1.3.6.1.4.1.4756.20.452.40.1.93 | Columnf100AS1VID12RemoteB | read-write | current | RemoteB device VID 12: |
| 1.3.6.1.4.1.4756.20.452.40.1.94 | Columnf100AS1VID13RemoteB | read-write | current | RemoteB device VID 13: |
| 1.3.6.1.4.1.4756.20.452.40.1.95 | Columnf100AS1VID14RemoteB | read-write | current | RemoteB device VID 14: |
| 1.3.6.1.4.1.4756.20.452.40.1.96 | Columnf100AS1VID15RemoteB | read-write | current | RemoteB device VID 15: |
| 1.3.6.1.4.1.4756.20.452.40.1.97 | Columnf100AS1VID16RemoteB | read-write | current | RemoteB device VID 16: |
| 1.3.6.1.4.1.4756.20.452.40.1.98 | Columnf100AS1Port1Member1RemoteB | read-write | current | RemoteB device card port 1 member: 0:Unmodify 1:Untagged 2:Tagged 3:Nonmember |
| 1.3.6.1.4.1.4756.20.452.40.1.99 | Columnf100AS1Port1Member2RemoteB | read-write | current | RemoteB device card port 1 member 2: 0:Unmodify 1:Untagged 2:Tagged 3:Nonmember |
| 1.3.6.1.4.1.4756.20.452.40.1.100 | Columnf100AS1Port1Member3RemoteB | read-write | current | RemoteB device card port 1 member 3: 0:Unmodify 1:Untagged 2:Tagged 3:Nonmember |
| 1.3.6.1.4.1.4756.20.452.40.1.101 | Columnf100AS1Port1Member4RemoteB | read-write | current | RemoteB device card port 1 member 4: 0:Unmodify 1:Untagged 2:Tagged 3:Nonmember |
| 1.3.6.1.4.1.4756.20.452.40.1.102 | Columnf100AS1Port1Member5RemoteB | read-write | current | RemoteB device card port 1 member 5: 0:Unmodify 1:Untagged 2:Tagged 3:Nonmember |
| 1.3.6.1.4.1.4756.20.452.40.1.103 | Columnf100AS1Port1Member6RemoteB | read-write | current | RemoteB device card port 1 member 6: 0:Unmodify 1:Untagged 2:Tagged 3:Nonmember |
| 1.3.6.1.4.1.4756.20.452.40.1.104 | Columnf100AS1Port1Member7RemoteB | read-write | current | RemoteB device card port 1 member 7: 0:Unmodify 1:Untagged 2:Tagged 3:Nonmember |
| 1.3.6.1.4.1.4756.20.452.40.1.105 | Columnf100AS1Port1Member8RemoteB | read-write | current | RemoteB device card port 1 member 8: 0:Unmodify 1:Untagged 2:Tagged 3:Nonmember |
| 1.3.6.1.4.1.4756.20.452.40.1.106 | Columnf100AS1Port1Member9RemoteB | read-write | current | RemoteB device card port 1 member 9: 0:Unmodify 1:Untagged 2:Tagged 3:Nonmember |
| 1.3.6.1.4.1.4756.20.452.40.1.107 | Columnf100AS1Port1Member10RemoteB | read-write | current | RemoteB device card port 1 member 10: 0:Unmodify 1:Untagged 2:Tagged 3:Nonmember |
| 1.3.6.1.4.1.4756.20.452.40.1.108 | Columnf100AS1Port1Member11RemoteB | read-write | current | RemoteB device card port 1 member 11: 0:Unmodify 1:Untagged 2:Tagged 3:Nonmember |
| 1.3.6.1.4.1.4756.20.452.40.1.109 | Columnf100AS1Port1Member12RemoteB | read-write | current | RemoteB device card port 1 member 12: 0:Unmodify 1:Untagged 2:Tagged 3:Nonmember |
| 1.3.6.1.4.1.4756.20.452.40.1.110 | Columnf100AS1Port1Member13RemoteB | read-write | current | RemoteB device card port 1 member 13: 0:Unmodify 1:Untagged 2:Tagged 3:Nonmember |
| 1.3.6.1.4.1.4756.20.452.40.1.111 | Columnf100AS1Port1Member14RemoteB | read-write | current | RemoteB device card port 1 member 14: 0:Unmodify 1:Untagged 2:Tagged 3:Nonmember |
| 1.3.6.1.4.1.4756.20.452.40.1.112 | Columnf100AS1Port1Member15RemoteB | read-write | current | RemoteB device card port 1 member 15: 0:Unmodify 1:Untagged 2:Tagged 3:Nonmember |
| 1.3.6.1.4.1.4756.20.452.40.1.113 | Columnf100AS1Port1Member16RemoteB | read-write | current | RemoteB device card port 1 member 16: 0:Unmodify 1:Untagged 2:Tagged 3:Nonmember |
| 1.3.6.1.4.1.4756.20.452.40.1.114 | Columnf100AS1Port2Member1RemoteB | read-write | current | RemoteB device card port 2 member: 0:Unmodify 1:Untagged 2:Tagged 3:Nonmember |
| 1.3.6.1.4.1.4756.20.452.40.1.115 | Columnf100AS1Port2Member2RemoteB | read-write | current | RemoteB device card port 2 member 2: 0:Unmodify 1:Untagged 2:Tagged 3:Nonmember |
| 1.3.6.1.4.1.4756.20.452.40.1.116 | Columnf100AS1Port2Member3RemoteB | read-write | current | RemoteB device card port 2 member 3: 0:Unmodify 1:Untagged 2:Tagged 3:Nonmember |
| 1.3.6.1.4.1.4756.20.452.40.1.117 | Columnf100AS1Port2Member4RemoteB | read-write | current | RemoteB device card port 2 member 4: 0:Unmodify 1:Untagged 2:Tagged 3:Nonmember |
| 1.3.6.1.4.1.4756.20.452.40.1.118 | Columnf100AS1Port2Member5RemoteB | read-write | current | RemoteB device card port 2 member 5: 0:Unmodify 1:Untagged 2:Tagged 3:Nonmember |
| 1.3.6.1.4.1.4756.20.452.40.1.119 | Columnf100AS1Port2Member6RemoteB | read-write | current | RemoteB device card port 2 member 6: 0:Unmodify 1:Untagged 2:Tagged 3:Nonmember |
| 1.3.6.1.4.1.4756.20.452.40.1.120 | Columnf100AS1Port2Member7RemoteB | read-write | current | RemoteB device card port 2 member 7: 0:Unmodify 1:Untagged 2:Tagged 3:Nonmember |
| 1.3.6.1.4.1.4756.20.452.40.1.121 | Columnf100AS1Port2Member8RemoteB | read-write | current | RemoteB device card port 2 member 8: 0:Unmodify 1:Untagged 2:Tagged 3:Nonmember |
| 1.3.6.1.4.1.4756.20.452.40.1.122 | Columnf100AS1Port2Member9RemoteB | read-write | current | RemoteB device card port 2 member 9: 0:Unmodify 1:Untagged 2:Tagged 3:Nonmember |
| 1.3.6.1.4.1.4756.20.452.40.1.123 | Columnf100AS1Port2Member10RemoteB | read-write | current | RemoteB device card port 2 member 10: 0:Unmodify 1:Untagged 2:Tagged 3:Nonmember |
| 1.3.6.1.4.1.4756.20.452.40.1.124 | Columnf100AS1Port2Member11RemoteB | read-write | current | RemoteB device card port 2 member 11: 0:Unmodify 1:Untagged 2:Tagged 3:Nonmember |
| 1.3.6.1.4.1.4756.20.452.40.1.125 | Columnf100AS1Port2Member12RemoteB | read-write | current | RemoteB device card port 2 member 12: 0:Unmodify 1:Untagged 2:Tagged 3:Nonmember |
| 1.3.6.1.4.1.4756.20.452.40.1.126 | Columnf100AS1Port2Member13RemoteB | read-write | current | RemoteB device card port 2 member 13: 0:Unmodify 1:Untagged 2:Tagged 3:Nonmember |
| 1.3.6.1.4.1.4756.20.452.40.1.127 | Columnf100AS1Port2Member14RemoteB | read-write | current | RemoteB device card port 2 member 14: 0:Unmodify 1:Untagged 2:Tagged 3:Nonmember |
| 1.3.6.1.4.1.4756.20.452.40.1.128 | Columnf100AS1Port2Member15RemoteB | read-write | current | RemoteB device card port 2 member 15: 0:Unmodify 1:Untagged 2:Tagged 3:Nonmember |
| 1.3.6.1.4.1.4756.20.452.40.1.129 | Columnf100AS1Port2Member16RemoteB | read-write | current | RemoteB device card port 2 member 16: 0:Unmodify 1:Untagged 2:Tagged 3:Nonmember |
| 1.3.6.1.4.1.4756.20.452.40.1.130 | Columnf100AS1IpAddressRemoteB | read-write | current | RemoteB device IP address |
| 1.3.6.1.4.1.4756.20.452.40.1.131 | Columnf100AS1NetMaskRemoteB | read-write | current | RemoteB device Netmask |
| 1.3.6.1.4.1.4756.20.452.40.1.132 | Columnf100AS1GateWayRemoteB | read-write | current | RemoteB device Gateway |
| 1.3.6.1.4.1.4756.20.452.40.1.133 | Columnf100AS1SetDefaultRemoteB | read-write | current | RemoteB device set to default |
| 1.3.6.1.4.1.4756.20.452.40.1.134 | Columnf100AS1ManagementVIDRemoteB | read-write | current | RemoteB device Management VID : |
| 1.3.6.1.4.1.4756.20.452.40.1.135 | Columnf100AS1TagTypeRemoteB | read-write | current | RemoteB device Tag Type (HEX) : |
| 1.3.6.1.4.1.4756.20.452.40.1.136 | Columnf100AS1FxLinkAlarmRemoteB | read-write | current | RemoteB device fiber link alarm 0:Disable 1:Enable |
| 1.3.6.1.4.1.4756.20.452.40.1.137 | Columnf100AS1UtpLinkAlarmRemoteB | read-write | current | RemoteB device utp link alarm 0:Disable 1:Enable |
| 1.3.6.1.4.1.4756.20.452.40.1.138 | Columnf100AS1RemoteTLPTRemoteB | read-write | current | RemoteB device Remote TLPT mode : 0:Disalbe 1:Remote |
| 1.3.6.1.4.1.4756.20.460 | Nodefxofxs4LocalCards | |||
| 1.3.6.1.4.1.4756.20.460.20 | Tablefxofxs4LocalTable | not-accessible | current | A list of local FRM220-FXO/FXS-4 card entries. The number of entries is fxoFXS-No-L. |
| 1.3.6.1.4.1.4756.20.460.20.1 | Rowfxofxs4LocalEntry | not-accessible | current | An entry containing management information applicable to a particular local FRM220-FXO/FXS-4 card. |
| 1.3.6.1.4.1.4756.20.460.20.1.1 | Columnfxofxs4ChassisIndexLocal | read-only | current | A unique value for each local card. It is the chassis location number. |
| 1.3.6.1.4.1.4756.20.460.20.1.2 | Columnfxofxs4SlotIndexLocal | read-only | current | A unique value for each local card. It is the slot location number. |
| 1.3.6.1.4.1.4756.20.460.20.1.3 | Columnfxofxs4CardHWVerLocal | read-only | current | Local FRM220-FXO/FXS-4 card hardware version x.xxx |
| 1.3.6.1.4.1.4756.20.460.20.1.4 | Columnfxofxs4CardFWVerLocal | read-only | current | Local FRM220-FXO/FXS-4 card firmware version x.xxx |
| 1.3.6.1.4.1.4756.20.460.20.1.5 | Columnfxofxs4CardCPLDVerLocal | read-only | current | Local FRM220-FXO/FXS card CPLD version x.xxx |
| 1.3.6.1.4.1.4756.20.460.20.1.6 | Columnfxofxs4CardFPGAVerLocal | read-only | current | Local FRM220-FXO/FXS card FPGA version x.xxx |
| 1.3.6.1.4.1.4756.20.460.20.1.7 | Columnfxofxs4ModelLocal | read-only | current | Local FRM220-FXO/FXS-4 Mode: 0:FRM220-FXO-4 1:FRM220-FXS-4 |
| 1.3.6.1.4.1.4756.20.460.20.1.8 | Columnfxofxs4FxLinkLocal | read-only | current | Local FRM220-FXO/FXS-4 fiber link state: 0:Link Down 1:Link Up |
| 1.3.6.1.4.1.4756.20.460.20.1.9 | Columnfxofxs4FxFEFLocal | read-only | current | Local FRM220-FXO/FXS-4 card fiber detected Far End Fault: 0:Off 1:Detected |
| 1.3.6.1.4.1.4756.20.460.20.1.10 | Columnfxofxs4FxDDLocal | read-only | current | Local FRM220-FXO/FXS-4 card fiber Digital Diagnostic function: 0:No 1:Yes |
| 1.3.6.1.4.1.4756.20.460.20.1.11 | Columnfxofxs4FxPortActiveLocal | read-write | current | Local FRM220-FXO/FXS-4 card Port Active: 0:Disable 1:Enable |
| 1.3.6.1.4.1.4756.20.460.20.1.12 | Columnfxofxs4FxALSModeLocal | read-write | current | Local FRM220-FXO/FXS-4 card Auto Laser Shutdown : 0:Disable 1:Enable |
| 1.3.6.1.4.1.4756.20.460.20.1.13 | Columnfxofxs4FxBitErrorCounterLocal | read-only | current | Local FRM220-FXO/FXS-4 card Bert Bit Error Counter |
| 1.3.6.1.4.1.4756.20.460.20.1.14 | Columnfxofxs4FxInsertOneBitErrorLocal | read-write | current | Local FRM220-FXO/FXS-4 card Bert Insert One Bit Error: 0:Off 1:Action |
| 1.3.6.1.4.1.4756.20.460.20.1.15 | Columnfxofxs4FxClearBitErrorCounterLocal | read-write | current | Local FRM220-FXO/FXS-4 card Clear Bit Error Counter: 0:Off 1:Action |
| 1.3.6.1.4.1.4756.20.460.20.1.16 | Columnfxofxs4Channel1ActiveStsLocal | read-only | current | Local FRM220-FXO/FXS-4 Channel 1 Active State: 0:NO 1:YES |
| 1.3.6.1.4.1.4756.20.460.20.1.17 | Columnfxofxs4Channel1RingStsLocal | read-only | current | Local FRM220-FXO/FXS-4 card Channel 1 Ring State: 0:No Ring 1:Ringing |
| 1.3.6.1.4.1.4756.20.460.20.1.18 | Columnfxofxs4Channel1HookLocal | read-only | current | Local FRM220-FXO/FXS-4 card Channel 1 Hook: 0:on-hook 1:off-hook |
| 1.3.6.1.4.1.4756.20.460.20.1.19 | Columnfxofxs4Channel2ActiveStsLocal | read-only | current | Local FRM220-FXO/FXS-4 Channel 2 Active State: 0:NO 1:YES |
| 1.3.6.1.4.1.4756.20.460.20.1.20 | Columnfxofxs4Channel2RingStsLocal | read-only | current | Local FRM220-FXO/FXS-4 card Channel 2 Ring State: 0:No Ring 1:Ringing |
| 1.3.6.1.4.1.4756.20.460.20.1.21 | Columnfxofxs4Channel2HookLocal | read-only | current | Local FRM220-FXO/FXS-4 card Channel 2 Hook: 0:on-hook 1:off-hook |
| 1.3.6.1.4.1.4756.20.460.20.1.22 | Columnfxofxs4Channel3ActiveStsLocal | read-only | current | Local FRM220-FXO/FXS-4 Channel 3 Active State: 0:NO 1:YES |
| 1.3.6.1.4.1.4756.20.460.20.1.23 | Columnfxofxs4Channel3RingStsLocal | read-only | current | Local FRM220-FXO/FXS-4 card Channel 3 Ring State: 0:No Ring 1:Ringing |
| 1.3.6.1.4.1.4756.20.460.20.1.24 | Columnfxofxs4Channel3HookLocal | read-only | current | Local FRM220-FXO/FXS-4 card Channel 3 Hook: 0:on-hook 1:off-hook |
| 1.3.6.1.4.1.4756.20.460.20.1.25 | Columnfxofxs4Channel4ActiveStsLocal | read-only | current | Local FRM220-FXO/FXS-4 Channel 4 Active State: 0:NO 1:YES |
| 1.3.6.1.4.1.4756.20.460.20.1.26 | Columnfxofxs4Channel4RingStsLocal | read-only | current | Local FRM220-FXO/FXS-4 card Channel 4 Ring State: 0:No Ring 1:Ringing |
| 1.3.6.1.4.1.4756.20.460.20.1.27 | Columnfxofxs4Channel4HookLocal | read-only | current | Local FRM220-FXO/FXS-4 card Channel 4 Hook: 0:on-hook 1:off-hook |
| 1.3.6.1.4.1.4756.20.460.20.1.28 | Columnfxofxs4RingFreqLocal | read-write | current | Local FRM220-FXO/FXS-4 card ring frequency FXO-4: 0: 50/55Hz 1: 40/45Hz 2: 30/35Hz 3: 20/25Hz FXS-4: 4: 55Hz 5: 50Hz 6: 45Hz 7: 40Hz 8: 35Hz 9: 30Hz 10: 25Hz 1… |
| 1.3.6.1.4.1.4756.20.460.20.1.29 | Columnfxofxs4AreaModeLocal | read-write | current | Local FRM220-FXO/FXS-4 card area mode (FXO-4 only) 0: Area1 1: Area2 2: Area3 3: Area4 4: Area5 5: Area6 6: Area7 7: Area8 8: Area9 9: Area10 10: Area11 11: Ar… |
| 1.3.6.1.4.1.4756.20.460.20.1.30 | Columnfxofxs4RingingStyleLocal | read-write | current | Local FRM220-FXO/FXS-4 card ringing style (FXS-4 only) 0: On:0.40s Off:0.20s 1: On:0.75s Off:7.50s 2: On:1.00s Off:3.00s 3: On:1.00s Off:4.00s 4: On:1.00s Off:… |
| 1.3.6.1.4.1.4756.20.460.20.1.31 | Columnfxofxs4RingONLocal | read-write | current | Local FRM220-FXO/FXS-4 card ring on (FXS-4 only) Range: 1 ms ~ 8190 ms |
| 1.3.6.1.4.1.4756.20.460.20.1.32 | Columnfxofxs4RingOFFLocal | read-write | current | Local FRM220-FXO/FXS-4 card ring off (FXS-4 only) Range: 1 ms ~ 8190 ms |
| 1.3.6.1.4.1.4756.20.460.20.1.33 | Columnfxofxs4PortResetLocal | read-write | current | Force remote FRM220-FXO/FXS-4 card reset mode: 0:Off 1:Action |
| 1.3.6.1.4.1.4756.20.460.20.1.34 | Columnfxofxs4SetDefaultLocal | read-write | current | Force remote FRM220-FXO/FXS-4 card to default status: 0:Off 1:Action |
| 1.3.6.1.4.1.4756.20.460.20.1.35 | Columnfxofxs4DDVendorLocal | read-only | current | Local FRM220-FXO/FXS-4 card fiber D/D information: Vendor name |
| 1.3.6.1.4.1.4756.20.460.20.1.36 | Columnfxofxs4DDPartNoLocal | read-only | current | Local FRM220-FXO/FXS-4 card fiber D/D information: Vendor part number |
| 1.3.6.1.4.1.4756.20.460.20.1.37 | Columnfxofxs4DDFiberTypeLocal | read-only | current | Local FRM220-FXO/FXS-4 card fiber D/D information: Fiber Type |
| 1.3.6.1.4.1.4756.20.460.20.1.38 | Columnfxofxs4DDWaveLenLocal | read-only | current | Local FRM220-FXO/FXS-4 card fiber D/D information: Wave length |
| 1.3.6.1.4.1.4756.20.460.20.1.39 | Columnfxofxs4DDWaveLen2Local | read-only | current | Local FRM220-FXO/FXS-4 card fiber D/D information: Wave length 2 |
| 1.3.6.1.4.1.4756.20.460.20.1.40 | Columnfxofxs4DDLinkLenLocal | read-only | current | Local FRM220-FXO/FXS-4 card fiber D/D information: Link length |
| 1.3.6.1.4.1.4756.20.460.20.1.41 | Columnfxofxs4DDLenUnitLocal | read-only | current | Local FRM220-FXO/FXS-4 card fiber D/D information: Length Unit |
| 1.3.6.1.4.1.4756.20.460.20.1.42 | Columnfxofxs4DDStatusLocal | read-only | current | Local FRM220-FXO/FXS-4 card fiber D/D information: Status Support |
| 1.3.6.1.4.1.4756.20.460.20.1.43 | Columnfxofxs4DDRxSensLocal | read-only | current | Local FRM220-FXO/FXS-4 card fiber D/D information: Rx Sensitivity |
| 1.3.6.1.4.1.4756.20.460.20.1.44 | Columnfxofxs4DDTxPwrLocal | read-only | current | Local FRM220-FXO/FXS-4 card fiber D/D information: Tx power |
| 1.3.6.1.4.1.4756.20.460.20.1.45 | Columnfxofxs4DDRxPwrLocal | read-only | current | Local FRM220-FXO/FXS-4 card fiber D/D information: Rx power |
| 1.3.6.1.4.1.4756.20.460.20.1.46 | Columnfxofxs4DDTempLocal | read-only | current | Local FRM220-FXO/FXS-4 card fiber D/D information: Temperature in degree C |
| 1.3.6.1.4.1.4756.20.460.20.1.47 | Columnfxofxs4DDPwrMarginLocal | read-only | current | Local FRM220-FXO/FXS-4 card fiber D/D information: Power margin |
| 1.3.6.1.4.1.4756.20.460.20.1.48 | Columnfxofxs4DDPwrLossLocal | read-only | current | Local FRM220-FXO/FXS-4 card fiber D/D information: Power loss |
| 1.3.6.1.4.1.4756.20.460.20.1.49 | Columnfxofxs4FxLedStatusLocal | read-only | current | Local FRM220-FXO/FXS-4 card fiber led status: 0: OFF 1: Flash 2: ON |
| 1.3.6.1.4.1.4756.20.461 | Nodefxofxs4RemoteCards | |||
| 1.3.6.1.4.1.4756.20.461.20 | Tablefxofxs4RemoteTable | not-accessible | current | A list of Remote FRM220-FXO/FXS-4 card entries. The number of entries is fxoFXS-No-L. |
| 1.3.6.1.4.1.4756.20.461.20.1 | Rowfxofxs4RemoteEntry | not-accessible | current | An entry containing management information applicable to a particular Remote FRM220-FXO/FXS-4 card. |
| 1.3.6.1.4.1.4756.20.461.20.1.1 | Columnfxofxs4ChassisIndexRemote | read-only | current | A unique value for each Remote card. It is the chassis location number. |
| 1.3.6.1.4.1.4756.20.461.20.1.2 | Columnfxofxs4SlotIndexRemote | read-only | current | A unique value for each Remote card. It is the slot location number. |
| 1.3.6.1.4.1.4756.20.461.20.1.3 | Columnfxofxs4CardHWVerRemote | read-only | current | Remote FRM220-FXO/FXS-4 card hardware version x.xxx |
| 1.3.6.1.4.1.4756.20.461.20.1.4 | Columnfxofxs4CardFWVerRemote | read-only | current | Remote FRM220-FXO/FXS-4 card firmware version x.xxx |
| 1.3.6.1.4.1.4756.20.461.20.1.5 | Columnfxofxs4CardCPLDVerRemote | read-only | current | Remote FRM220-FXO/FXS card CPLD version x.xxx |
| 1.3.6.1.4.1.4756.20.461.20.1.6 | Columnfxofxs4CardFPGAVerRemote | read-only | current | Remote FRM220-FXO/FXS card FPGA version x.xxx |
| 1.3.6.1.4.1.4756.20.461.20.1.7 | Columnfxofxs4ModelRemote | read-only | current | Remote FRM220-FXO/FXS-4 Mode: 0:FRM220-FXO-4 1:FRM220-FXS-4 |
| 1.3.6.1.4.1.4756.20.461.20.1.8 | Columnfxofxs4FxLinkRemote | read-only | current | Remote FRM220-FXO/FXS-4 fiber link state: 0:Link Down 1:Link Up |
| 1.3.6.1.4.1.4756.20.461.20.1.9 | Columnfxofxs4FxFEFRemote | read-only | current | Remote FRM220-FXO/FXS-4 card fiber detected Far End Fault: 0:Off 1:Detected |
| 1.3.6.1.4.1.4756.20.461.20.1.10 | Columnfxofxs4FxDDRemote | read-only | current | Remote FRM220-FXO/FXS-4 card fiber Digital Diagnostic function: 0:No 1:Yes |
| 1.3.6.1.4.1.4756.20.461.20.1.11 | Columnfxofxs4FxPortActiveRemote | read-only | current | Remote FRM220-FXO/FXS-4 card Port Active: 0:Disable 1:Enable |
| 1.3.6.1.4.1.4756.20.461.20.1.12 | Columnfxofxs4FxALSModeRemote | read-write | current | Remote FRM220-FXO/FXS-4 card Auto Laser Shutdown : 0:Disable 1:Enable |
| 1.3.6.1.4.1.4756.20.461.20.1.13 | Columnfxofxs4FxBitErrorCounterRemote | read-only | current | Remote FRM220-FXO/FXS-4 card Bert Bit Error Counter |
| 1.3.6.1.4.1.4756.20.461.20.1.14 | Columnfxofxs4FxInsertOneBitErrorRemote | read-write | current | Remote FRM220-FXO/FXS-4 card Bert Insert One Bit Error: 0:Off 1:Action |
| 1.3.6.1.4.1.4756.20.461.20.1.15 | Columnfxofxs4FxClearBitErrorCounterRemote | read-write | current | Remote FRM220-FXO/FXS-4 card Clear Bit Error Counter: 0:Off 1:Action |
| 1.3.6.1.4.1.4756.20.461.20.1.16 | Columnfxofxs4Channel1ActiveStsRemote | read-only | current | Remote FRM220-FXO/FXS-4 Channel 1 Active State: 0:NO 1:YES |
| 1.3.6.1.4.1.4756.20.461.20.1.17 | Columnfxofxs4Channel1RingStsRemote | read-only | current | Remote FRM220-FXO/FXS-4 card Channel 1 Ring State: 0:No Ring 1:Ringing |
| 1.3.6.1.4.1.4756.20.461.20.1.18 | Columnfxofxs4Channel1HookRemote | read-only | current | Remote FRM220-FXO/FXS-4 card Channel 1 Hook: 0:on-hook 1:off-hook |
| 1.3.6.1.4.1.4756.20.461.20.1.19 | Columnfxofxs4Channel2ActiveStsRemote | read-only | current | Remote FRM220-FXO/FXS-4 Channel 2 Active State: 0:NO 1:YES |
| 1.3.6.1.4.1.4756.20.461.20.1.20 | Columnfxofxs4Channel2RingStsRemote | read-only | current | Remote FRM220-FXO/FXS-4 card Channel 2 Ring State: 0:No Ring 1:Ringing |
| 1.3.6.1.4.1.4756.20.461.20.1.21 | Columnfxofxs4Channel2HookRemote | read-only | current | Remote FRM220-FXO/FXS-4 card Channel 2 Hook: 0:on-hook 1:off-hook |
| 1.3.6.1.4.1.4756.20.461.20.1.22 | Columnfxofxs4Channel3ActiveStsRemote | read-only | current | Remote FRM220-FXO/FXS-4 Channel 3 Active State: 0:NO 1:YES |
| 1.3.6.1.4.1.4756.20.461.20.1.23 | Columnfxofxs4Channel3RingStsRemote | read-only | current | Remote FRM220-FXO/FXS-4 card Channel 3 Ring State: 0:No Ring 1:Ringing |
| 1.3.6.1.4.1.4756.20.461.20.1.24 | Columnfxofxs4Channel3HookRemote | read-only | current | Remote FRM220-FXO/FXS-4 card Channel 3 Hook: 0:on-hook 1:off-hook |
| 1.3.6.1.4.1.4756.20.461.20.1.25 | Columnfxofxs4Channel4ActiveStsRemote | read-only | current | Remote FRM220-FXO/FXS-4 Channel 4 Active State: 0:NO 1:YES |
| 1.3.6.1.4.1.4756.20.461.20.1.26 | Columnfxofxs4Channel4RingStsRemote | read-only | current | Remote FRM220-FXO/FXS-4 card Channel 4 Ring State: 0:No Ring 1:Ringing |
| 1.3.6.1.4.1.4756.20.461.20.1.27 | Columnfxofxs4Channel4HookRemote | read-only | current | Remote FRM220-FXO/FXS-4 card Channel 4 Hook: 0:on-hook 1:off-hook |
| 1.3.6.1.4.1.4756.20.461.20.1.28 | Columnfxofxs4RingFreqRemote | read-write | current | Remote FRM220-FXO/FXS-4 card ring frequency FXO-4: 0: 50/55Hz 1: 40/45Hz 2: 30/35Hz 3: 20/25Hz FXS-4: 4: 55Hz 5: 50Hz 6: 45Hz 7: 40Hz 8: 35Hz 9: 30Hz 10: 25Hz … |
| 1.3.6.1.4.1.4756.20.461.20.1.29 | Columnfxofxs4AreaModeRemote | read-write | current | Remote FRM220-FXO/FXS-4 card area mode (FXO-4 only) 0: Area1 1: Area2 2: Area3 3: Area4 4: Area5 5: Area6 6: Area7 7: Area8 8: Area9 9: Area10 10: Area11 11: A… |
| 1.3.6.1.4.1.4756.20.461.20.1.30 | Columnfxofxs4RingingStyleRemote | read-write | current | Remote FRM220-FXO/FXS-4 card ringing style (FXS-4 only) 0: On:0.40s Off:0.20s 1: On:0.75s Off:7.50s 2: On:1.00s Off:3.00s 3: On:1.00s Off:4.00s 4: On:1.00s Off… |
| 1.3.6.1.4.1.4756.20.461.20.1.31 | Columnfxofxs4RingONRemote | read-write | current | Remote FRM220-FXO/FXS-4 card ring on (FXS-4 only) Range: 1 ms ~ 8190 ms |
| 1.3.6.1.4.1.4756.20.461.20.1.32 | Columnfxofxs4RingOFFRemote | read-write | current | Remote FRM220-FXO/FXS-4 card ring off (FXS-4 only) Range: 1 ms ~ 8190 ms |
| 1.3.6.1.4.1.4756.20.461.20.1.33 | Columnfxofxs4PortResetRemote | read-write | current | Force remote FRM220-FXO/FXS-4 card to reset mode: 0:Off 1:Action |
| 1.3.6.1.4.1.4756.20.461.20.1.34 | Columnfxofxs4SetDefaultRemote | read-write | current | Force remote FRM220-FXO/FXS-4 card to default status: 0:Off 1:Action |
| 1.3.6.1.4.1.4756.20.461.20.1.35 | Columnfxofxs4DDVendorRemote | read-only | current | Remote FRM220-FXO/FXS-4 card fiber D/D information: Vendor name |
| 1.3.6.1.4.1.4756.20.461.20.1.36 | Columnfxofxs4DDPartNoRemote | read-only | current | Remote FRM220-FXO/FXS-4 card fiber D/D information: Vendor part number |
| 1.3.6.1.4.1.4756.20.461.20.1.37 | Columnfxofxs4DDFiberTypeRemote | read-only | current | Remote FRM220-FXO/FXS-4 card fiber D/D information: Fiber Type |
| 1.3.6.1.4.1.4756.20.461.20.1.38 | Columnfxofxs4DDWaveLenRemote | read-only | current | Remote FRM220-FXO/FXS-4 card fiber D/D information: Wave length |
| 1.3.6.1.4.1.4756.20.461.20.1.39 | Columnfxofxs4DDWaveLen2Remote | read-only | current | Remote FRM220-FXO/FXS-4 card fiber D/D information: Wave length 2 |
| 1.3.6.1.4.1.4756.20.461.20.1.40 | Columnfxofxs4DDLinkLenRemote | read-only | current | Remote FRM220-FXO/FXS-4 card fiber D/D information: Link length |
| 1.3.6.1.4.1.4756.20.461.20.1.41 | Columnfxofxs4DDLenUnitRemote | read-only | current | Remote FRM220-FXO/FXS-4 card fiber D/D information: Length Unit |
| 1.3.6.1.4.1.4756.20.461.20.1.42 | Columnfxofxs4DDStatusRemote | read-only | current | Remote FRM220-FXO/FXS-4 card fiber D/D information: Status Support |
| 1.3.6.1.4.1.4756.20.461.20.1.43 | Columnfxofxs4DDRxSensRemote | read-only | current | Remote FRM220-FXO/FXS-4 card fiber D/D information: Rx Sensitivity |
| 1.3.6.1.4.1.4756.20.461.20.1.44 | Columnfxofxs4DDTxPwrRemote | read-only | current | Remote FRM220-FXO/FXS-4 card fiber D/D information: Tx power |
| 1.3.6.1.4.1.4756.20.461.20.1.45 | Columnfxofxs4DDRxPwrRemote | read-only | current | Remote FRM220-FXO/FXS-4 card fiber D/D information: Rx power |
| 1.3.6.1.4.1.4756.20.461.20.1.46 | Columnfxofxs4DDTempRemote | read-only | current | Remote FRM220-FXO/FXS-4 card fiber D/D information: Temperature in degree C |
| 1.3.6.1.4.1.4756.20.461.20.1.47 | Columnfxofxs4DDPwrMarginRemote | read-only | current | Remote FRM220-FXO/FXS-4 card fiber D/D information: Power margin |
| 1.3.6.1.4.1.4756.20.461.20.1.48 | Columnfxofxs4DDPwrLossRemote | read-only | current | Remote FRM220-FXO/FXS-4 card fiber D/D information: Power loss |
| 1.3.6.1.4.1.4756.20.461.20.1.49 | Columnfxofxs4FxLedStatusRemote | read-only | current | Remote FRM220-FXO/FXS-4 card fiber led status: 0: OFF 1: Flash 2: ON |
| 1.3.6.1.4.1.4756.20.470 | NodegfomLocalCards | |||
| 1.3.6.1.4.1.4756.20.470.20 | TablegfomLocalTable | not-accessible | current | A list of Local FRM220-GFOM04/08 card entries. |
| 1.3.6.1.4.1.4756.20.470.20.1 | RowgfomLocalEntry | not-accessible | current | An entry containing management information applicable to a particular Local FRM220-GFOM04/08 card. |
| 1.3.6.1.4.1.4756.20.470.20.1.1 | ColumngfomChassisIndexLocal | read-only | current | A unique value for each local card. It is the chassis location number. |
| 1.3.6.1.4.1.4756.20.470.20.1.2 | ColumngfomSlotIndexLocal | read-only | current | A unique value for each local card. It is the slot location number. |
| 1.3.6.1.4.1.4756.20.470.20.1.3 | ColumngfomCardHWVerLocal | read-only | current | Local FRM220-GFOM04/08 card hardware version x.xxx |
| 1.3.6.1.4.1.4756.20.470.20.1.4 | ColumngfomCardFWVerLocal | read-only | current | Local FRM220-GFOM04/08 card firmware version x.xxx |
| 1.3.6.1.4.1.4756.20.470.20.1.5 | ColumngfomCardCPLDVerLocal | read-only | current | Local FRM220-GFOM04/08 card CPLD version x.xxx |
| 1.3.6.1.4.1.4756.20.470.20.1.6 | ColumngfomCardFPGAVerLocal | read-only | current | Local FRM220-GFOM04/08 card FPGA version x.xxx |
| 1.3.6.1.4.1.4756.20.470.20.1.7 | ColumngfomModelLocal | read-only | current | Local FRM220-GFOM04/08 Mode: 0:FRM220-GFOM04 1:FRM220-GFOM08 |
| 1.3.6.1.4.1.4756.20.470.20.1.8 | ColumngfomFx1LinkLocal | read-only | current | Local FRM220-GFOM04/08 card fiber1 link state: 0:Link Down 1:Link Up |
| 1.3.6.1.4.1.4756.20.470.20.1.9 | ColumngfomFx1TypeLocal | read-only | current | Local FRM220-GFOM04/08 card fiber1 fiber type: 0:1*9 1:SFP |
| 1.3.6.1.4.1.4756.20.470.20.1.10 | ColumngfomFx1TxFaultLocal | read-only | current | Local FRM220-GFOM04/08 card fiber1 Tx fault: 0:Normal 1:Fault |
| 1.3.6.1.4.1.4756.20.470.20.1.11 | ColumngfomFx1DDLocal | read-only | current | Local FRM220-GFOM04/08 card fiber1 Digital Diagnostic function: 0:No 1:Yes |
| 1.3.6.1.4.1.4756.20.470.20.1.12 | ColumngfomFx2LinkLocal | read-only | current | Local FRM220-GFOM04/08 card fiber2 link state: 0:Link Down 1:Link Up |
| 1.3.6.1.4.1.4756.20.470.20.1.13 | ColumngfomFx2TypeLocal | read-only | current | Local FRM220-GFOM04/08 card fiber2 type: 0:1*9 1:SFP |
| 1.3.6.1.4.1.4756.20.470.20.1.14 | ColumngfomFx2TxFaultLocal | read-only | current | Local FRM220-GFOM04/08 card fiber2 Tx fault: 0:Normal 1:Fault |
| 1.3.6.1.4.1.4756.20.470.20.1.15 | ColumngfomFx2DDLocal | read-only | current | Local FRM220-GFOM04/08 fiber2 Digital Diagnostic function: 0:No 1:Yes |
| 1.3.6.1.4.1.4756.20.470.20.1.16 | ColumngfomFxWorkingPathLocal | read-only | current | Local FRM220-GFOM04/08 card Fx Working Path Status: 0:OP1 1:OP2 |
| 1.3.6.1.4.1.4756.20.470.20.1.17 | ColumngfomFxBitErrorCounterLocal | read-only | current | Local FRM220-GFOM04/08 card Fx Bit Error Counter |
| 1.3.6.1.4.1.4756.20.470.20.1.18 | ColumngfomFxProtectionModeLocal | read-write | current | Local FRM220-GFOM04/08 card Fx Protection Mode: 0:Auto, Non-Revert 1:Auto, Revert 2:Manual Fx1 3:Manual Fx2 |
| 1.3.6.1.4.1.4756.20.470.20.1.19 | ColumngfomFxALSLocal | read-write | current | Local FRM220-GFOM04/08 card Fx Auto Laser Shutdown : 0:Disable 1:Enable |
| 1.3.6.1.4.1.4756.20.470.20.1.20 | ColumngfomFxLoopbackTestLocal | read-write | current | Local FRM220-GFOM04/08 card Fx Loopback Test: 0:Disable 1:LLB 2:RLB 3:RRLB |
| 1.3.6.1.4.1.4756.20.470.20.1.21 | ColumngfomFxInserOneErrorBitLocal | read-write | current | Local FRM220-GFOM04/08 card Fx Bert Insert One Bit Error: 0:Off 1:Action |
| 1.3.6.1.4.1.4756.20.470.20.1.22 | ColumngfomFxClearBitErrorCounterLocal | read-write | current | Local FRM220-GFOM04/08 card Fx Clear Bit Error Counter: 0:Off 1:Action |
| 1.3.6.1.4.1.4756.20.470.20.1.23 | ColumngfomUTPLinkStatusLocal | read-only | current | Local FRM220-GFOM04/08 card UTP link state: 0:Link Down 1:Link Up |
| 1.3.6.1.4.1.4756.20.470.20.1.24 | ColumngfomUTPSpeedStatusLocal | read-only | current | Local FRM220-GFOM04/08 card UTP speed state |
| 1.3.6.1.4.1.4756.20.470.20.1.25 | ColumngfomUTPDuplexStatusLocal | read-only | current | Local FRM220-GFOM04/08 card UTP duplex state |
| 1.3.6.1.4.1.4756.20.470.20.1.26 | ColumngfomUTPPortActiveLocal | read-write | current | Local FRM220-GFOM04/08 card UTP Port Active : 0:Disable 1:Enable |
| 1.3.6.1.4.1.4756.20.470.20.1.27 | ColumngfomUTPNegotiationLocal | read-write | current | Local FRM220-GFOM04/08 card UTP Negotiation : 0:Auto 1:Manual |
| 1.3.6.1.4.1.4756.20.470.20.1.28 | ColumngfomUTPSpeedConfLocal | read-write | current | Local FRM220-GFOM04/08 card UTP Speed : 0:10M 1:100M 2:1000M |
| 1.3.6.1.4.1.4756.20.470.20.1.29 | ColumngfomUTPDuplexConfLocal | read-write | current | Local FRM220-GFOM04/08 card UTP Duplex : 0:Half 1:Full |
| 1.3.6.1.4.1.4756.20.470.20.1.30 | ColumngfomUTPFlowControlLocal | read-write | current | Local FRM220-GFOM04/08 card UTP Flow Control : 0:Disable 1:Enable |
| 1.3.6.1.4.1.4756.20.470.20.1.31 | ColumngfomUTPJumboFrameLocal | read-write | current | Local FRM220-GFOM04/08 card UTP Jumbo Frame : 0:Disable 1:Enable |
| 1.3.6.1.4.1.4756.20.470.20.1.32 | ColumngfomE1T1ModeLocal | read-write | current | Local FRM220-GFOM04/08 card E1/T1 Mode : 0:E1 (75 ohm) 1:E1 (120 ohm) 2:T1 (100 ohm) |
| 1.3.6.1.4.1.4756.20.470.20.1.33 | ColumngfomE1T1Channel1LinkStatusLocal | read-only | current | Local FRM220-GFOM04/08 card E1/T1 Channel 1 Link Status |
| 1.3.6.1.4.1.4756.20.470.20.1.34 | ColumngfomE1T1Channel1AISStatusLocal | read-only | current | Local FRM220-GFOM04/08 card E1/T1 Channel 1 AIS Status |
| 1.3.6.1.4.1.4756.20.470.20.1.35 | ColumngfomE1T1Channel1TxDriverFailureLocal | read-only | current | Local FRM220-GFOM04/08 card E1/T1 Channel 1 Tx Driver Failure |
| 1.3.6.1.4.1.4756.20.470.20.1.36 | ColumngfomE1T1Channel1PerformanceLocal | read-only | current | Local FRM220-GFOM04/08 card E1/T1 Channel 1 Performance |
| 1.3.6.1.4.1.4756.20.470.20.1.37 | ColumngfomE1T1Channel1ActiveLocal | read-write | current | Local FRM220-GFOM04/08 card E1/T1 Channel 1 Active : 0:Disable 1:Enable |
| 1.3.6.1.4.1.4756.20.470.20.1.38 | ColumngfomE1T1Channel1LinCodeLocal | read-write | current | Local FRM220-GFOM04/08 card E1/T1 Channel 1 Line Code : 0:HDB3/B8ZS 1:AMI |
| 1.3.6.1.4.1.4756.20.470.20.1.39 | ColumngfomE1T1Channel1AutoAISLocal | read-write | current | Local FRM220-GFOM04/08 card E1/T1 Channel 1 Auto AIS : 0:Disable 1:Enable |
| 1.3.6.1.4.1.4756.20.470.20.1.40 | ColumngfomE1T1Channel1LoopBackLocal | read-write | current | Local FRM220-GFOM04/08 card E1/T1 Channel 1 Loopback Test : 0:Disable 1:LLB 2:RLB 3:RRLB |
| 1.3.6.1.4.1.4756.20.470.20.1.41 | ColumngfomE1T1Channel2LinkStatusLocal | read-only | current | Local FRM220-GFOM04/08 card E1/T1 Channel 2 Link Status |
| 1.3.6.1.4.1.4756.20.470.20.1.42 | ColumngfomE1T1Channel2AISStatusLocal | read-only | current | Local FRM220-GFOM04/08 card E1/T1 Channel 2 AIS Status |
| 1.3.6.1.4.1.4756.20.470.20.1.43 | ColumngfomE1T1Channel2TxDriverFailureLocal | read-only | current | Local FRM220-GFOM04/08 card E1/T1 Channel 2 Tx Driver Failure |
| 1.3.6.1.4.1.4756.20.470.20.1.44 | ColumngfomE1T1Channel2PerformanceLocal | read-only | current | Local FRM220-GFOM04/08 card E1/T1 Channel 2 Performance |
| 1.3.6.1.4.1.4756.20.470.20.1.45 | ColumngfomE1T1Channel2ActiveLocal | read-write | current | Local FRM220-GFOM04/08 card E1/T1 Channel 2 Active : 0:Disable 1:Enable |
| 1.3.6.1.4.1.4756.20.470.20.1.46 | ColumngfomE1T1Channel2LinCodeLocal | read-write | current | Local FRM220-GFOM04/08 card E1/T1 Channel 2 Line Code : 0:HDB3/B8ZS 1:AMI |
| 1.3.6.1.4.1.4756.20.470.20.1.47 | ColumngfomE1T1Channel2AutoAISLocal | read-write | current | Local FRM220-GFOM04/08 card E1/T1 Channel 2 Auto AIS : 0:Disable 1:Enable |
| 1.3.6.1.4.1.4756.20.470.20.1.48 | ColumngfomE1T1Channel2LoopBackLocal | read-write | current | Local FRM220-GFOM04/08 card E1/T1 Channel 2 Loopback Test : 0:Disable 1:LLB 2:RLB 3:RRLB |
| 1.3.6.1.4.1.4756.20.470.20.1.49 | ColumngfomE1T1Channel3LinkStatusLocal | read-only | current | Local FRM220-GFOM04/08 card E1/T1 Channel 3 Link Status |
| 1.3.6.1.4.1.4756.20.470.20.1.50 | ColumngfomE1T1Channel3AISStatusLocal | read-only | current | Local FRM220-GFOM04/08 card E1/T1 Channel 3 AIS Status |
| 1.3.6.1.4.1.4756.20.470.20.1.51 | ColumngfomE1T1Channel3TxDriverFailureLocal | read-only | current | Local FRM220-GFOM04/08 card E1/T1 Channel 3 Tx Driver Failure |
| 1.3.6.1.4.1.4756.20.470.20.1.52 | ColumngfomE1T1Channel3PerformanceLocal | read-only | current | Local FRM220-GFOM04/08 card E1/T1 Channel 3 Performance |
| 1.3.6.1.4.1.4756.20.470.20.1.53 | ColumngfomE1T1Channel3ActiveLocal | read-write | current | Local FRM220-GFOM04/08 card E1/T1 Channel 3 Active : 0:Disable 1:Enable |
| 1.3.6.1.4.1.4756.20.470.20.1.54 | ColumngfomE1T1Channel3LinCodeLocal | read-write | current | Local FRM220-GFOM04/08 card E1/T1 Channel 3 Line Code : 0:HDB3/B8ZS 1:AMI |
| 1.3.6.1.4.1.4756.20.470.20.1.55 | ColumngfomE1T1Channel3AutoAISLocal | read-write | current | Local FRM220-GFOM04/08 card E1/T1 Channel 3 Auto AIS : 0:Disable 1:Enable |
| 1.3.6.1.4.1.4756.20.470.20.1.56 | ColumngfomE1T1Channel3LoopBackLocal | read-write | current | Local FRM220-GFOM04/08 card E1/T1 Channel 3 Loopback Test : 0:Disable 1:LLB 2:RLB 3:RRLB |
| 1.3.6.1.4.1.4756.20.470.20.1.57 | ColumngfomE1T1Channel4LinkStatusLocal | read-only | current | Local FRM220-GFOM04/08 card E1/T1 Channel 4 Link Status |
| 1.3.6.1.4.1.4756.20.470.20.1.58 | ColumngfomE1T1Channel4AISStatusLocal | read-only | current | Local FRM220-GFOM04/08 card E1/T1 Channel 4 AIS Status |
| 1.3.6.1.4.1.4756.20.470.20.1.59 | ColumngfomE1T1Channel4TxDriverFailureLocal | read-only | current | Local FRM220-GFOM04/08 card E1/T1 Channel 4 Tx Driver Failure |
| 1.3.6.1.4.1.4756.20.470.20.1.60 | ColumngfomE1T1Channel4PerformanceLocal | read-only | current | Local FRM220-GFOM04/08 card E1/T1 Channel 4 Performance |
| 1.3.6.1.4.1.4756.20.470.20.1.61 | ColumngfomE1T1Channel4ActiveLocal | read-write | current | Local FRM220-GFOM04/08 card E1/T1 Channel 4 Active : 0:Disable 1:Enable |
| 1.3.6.1.4.1.4756.20.470.20.1.62 | ColumngfomE1T1Channel4LinCodeLocal | read-write | current | Local FRM220-GFOM04/08 card E1/T1 Channel 4 Line Code : 0:HDB3/B8ZS 1:AMI |
| 1.3.6.1.4.1.4756.20.470.20.1.63 | ColumngfomE1T1Channel4AutoAISLocal | read-write | current | Local FRM220-GFOM04/08 card E1/T1 Channel 4 Auto AIS : 0:Disable 1:Enable |
| 1.3.6.1.4.1.4756.20.470.20.1.64 | ColumngfomE1T1Channel4LoopBackLocal | read-write | current | Local FRM220-GFOM04/08 card E1/T1 Channel 4 Loopback Test : 0:Disable 1:LLB 2:RLB 3:RRLB |
| 1.3.6.1.4.1.4756.20.470.20.1.65 | ColumngfomE1T1Channel5LinkStatusLocal | read-only | current | Local FRM220-GFOM04/08 card E1/T1 Channel 5 Link Status |
| 1.3.6.1.4.1.4756.20.470.20.1.66 | ColumngfomE1T1Channel5AISStatusLocal | read-only | current | Local FRM220-GFOM04/08 card E1/T1 Channel 5 AIS Status |
| 1.3.6.1.4.1.4756.20.470.20.1.67 | ColumngfomE1T1Channel5TxDriverFailureLocal | read-only | current | Local FRM220-GFOM04/08 card E1/T1 Channel 5 Tx Driver Failure |
| 1.3.6.1.4.1.4756.20.470.20.1.68 | ColumngfomE1T1Channel5PerformanceLocal | read-only | current | Local FRM220-GFOM04/08 card E1/T1 Channel 5 Performance |
| 1.3.6.1.4.1.4756.20.470.20.1.69 | ColumngfomE1T1Channel5ActiveLocal | read-write | current | Local FRM220-GFOM04/08 card E1/T1 Channel 5 Active : 0:Disable 1:Enable |
| 1.3.6.1.4.1.4756.20.470.20.1.70 | ColumngfomE1T1Channel5LinCodeLocal | read-write | current | Local FRM220-GFOM04/08 card E1/T1 Channel 5 Line Code : 0:HDB3/B8ZS 1:AMI |
| 1.3.6.1.4.1.4756.20.470.20.1.71 | ColumngfomE1T1Channel5AutoAISLocal | read-write | current | Local FRM220-GFOM04/08 card E1/T1 Channel5 Auto AIS : 0:Disable 1:Enable |
| 1.3.6.1.4.1.4756.20.470.20.1.72 | ColumngfomE1T1Channel5LoopBackLocal | read-write | current | Local FRM220-GFOM04/08 card E1/T1 Channel 5 Loopback Test : 0:Disable 1:LLB 2:RLB 3:RRLB |
| 1.3.6.1.4.1.4756.20.470.20.1.73 | ColumngfomE1T1Channel6LinkStatusLocal | read-only | current | Local FRM220-GFOM04/08 card E1/T1 Channel 6 Link Status |
| 1.3.6.1.4.1.4756.20.470.20.1.74 | ColumngfomE1T1Channel6AISStatusLocal | read-only | current | Local FRM220-GFOM04/08 card E1/T1 Channel 6 AIS Status |
| 1.3.6.1.4.1.4756.20.470.20.1.75 | ColumngfomE1T1Channel6TxDriverFailureLocal | read-only | current | Local FRM220-GFOM04/08 card E1/T1 Channel 6 Tx Driver Failure |
| 1.3.6.1.4.1.4756.20.470.20.1.76 | ColumngfomE1T1Channel6PerformanceLocal | read-only | current | Local FRM220-GFOM04/08 card E1/T1 Channel 6 Performance |
| 1.3.6.1.4.1.4756.20.470.20.1.77 | ColumngfomE1T1Channel6ActiveLocal | read-write | current | Local FRM220-GFOM04/08 card E1/T1 Channel 6 Active : 0:Disable 1:Enable |
| 1.3.6.1.4.1.4756.20.470.20.1.78 | ColumngfomE1T1Channel6LinCodeLocal | read-write | current | Local FRM220-GFOM04/08 card E1/T1 Channel 6 Line Code : 0:HDB3/B8ZS 1:AMI |
| 1.3.6.1.4.1.4756.20.470.20.1.79 | ColumngfomE1T1Channel6AutoAISLocal | read-write | current | Local FRM220-GFOM04/08 card E1/T1 Channel 6 Auto AIS : 0:Disable 1:Enable |
| 1.3.6.1.4.1.4756.20.470.20.1.80 | ColumngfomE1T1Channel6LoopBackLocal | read-write | current | Local FRM220-GFOM04/08 card E1/T1 Channel 6 Loopback Test : 0:Disable 1:LLB 2:RLB 3:RRLB |
| 1.3.6.1.4.1.4756.20.470.20.1.81 | ColumngfomE1T1Channel7LinkStatusLocal | read-only | current | Local FRM220-GFOM04/08 card E1/T1 Channel 7 Link Status |
| 1.3.6.1.4.1.4756.20.470.20.1.82 | ColumngfomE1T1Channel7AISStatusLocal | read-only | current | Local FRM220-GFOM04/08 card E1/T1 Channel 7 AIS Status |
| 1.3.6.1.4.1.4756.20.470.20.1.83 | ColumngfomE1T1Channel7TxDriverFailureLocal | read-only | current | Local FRM220-GFOM04/08 card E1/T1 Channel 7 Tx Driver Failure |
| 1.3.6.1.4.1.4756.20.470.20.1.84 | ColumngfomE1T1Channel7PerformanceLocal | read-only | current | Local FRM220-GFOM04/08 card E1/T1 Channel 7 Performance |
| 1.3.6.1.4.1.4756.20.470.20.1.85 | ColumngfomE1T1Channel7ActiveLocal | read-write | current | Local FRM220-GFOM04/08 card E1/T1 Channel 7 Active : 0:Disable 1:Enable |
| 1.3.6.1.4.1.4756.20.470.20.1.86 | ColumngfomE1T1Channel7LinCodeLocal | read-write | current | Local FRM220-GFOM04/08 card E1/T1 Channel 7 Line Code : 0:HDB3/B8ZS 1:AMI |
| 1.3.6.1.4.1.4756.20.470.20.1.87 | ColumngfomE1T1Channel7AutoAISLocal | read-write | current | Local FRM220-GFOM04/08 card E1/T1 Channel 7 Auto AIS : 0:Disable 1:Enable |
| 1.3.6.1.4.1.4756.20.470.20.1.88 | ColumngfomE1T1Channel7LoopBackLocal | read-write | current | Local FRM220-GFOM04/08 card E1/T1 Channel 7 Loopback Test : 0:Disable 1:LLB 2:RLB 3:RRLB |
| 1.3.6.1.4.1.4756.20.470.20.1.89 | ColumngfomE1T1Channel8LinkStatusLocal | read-only | current | Local FRM220-GFOM04/08 card E1/T1 Channel 8 Link Status |
| 1.3.6.1.4.1.4756.20.470.20.1.90 | ColumngfomE1T1Channel8AISStatusLocal | read-only | current | Local FRM220-GFOM04/08 card E1/T1 Channel 8 AIS Status |
| 1.3.6.1.4.1.4756.20.470.20.1.91 | ColumngfomE1T1Channel8TxDriverFailureLocal | read-only | current | Local FRM220-GFOM04/08 card E1/T1 Channel 8 Tx Driver Failure |
| 1.3.6.1.4.1.4756.20.470.20.1.92 | ColumngfomE1T1Channel8PerformanceLocal | read-only | current | Local FRM220-GFOM04/08 card E1/T1 Channel 8 Performance |
| 1.3.6.1.4.1.4756.20.470.20.1.93 | ColumngfomE1T1Channel8ActiveLocal | read-write | current | Local FRM220-GFOM04/08 card E1/T1 Channel 8 Active : 0:Disable 1:Enable |
| 1.3.6.1.4.1.4756.20.470.20.1.94 | ColumngfomE1T1Channel8LinCodeLocal | read-write | current | Local FRM220-GFOM04/08 card E1/T1 Channel 8 Line Code : 0:HDB3/B8ZS 1:AMI |
| 1.3.6.1.4.1.4756.20.470.20.1.95 | ColumngfomE1T1Channel8AutoAISLocal | read-write | current | Local FRM220-GFOM04/08 card E1/T1 Channel 8 Auto AIS : 0:Disable 1:Enable |
| 1.3.6.1.4.1.4756.20.470.20.1.96 | ColumngfomE1T1Channel8LoopBackLocal | read-write | current | Local FRM220-GFOM04/08 card E1/T1 Channel 8 Loopback Test : 0:Disable 1:LLB 2:RLB 3:RRLB |
| 1.3.6.1.4.1.4756.20.470.20.1.97 | ColumngfomE1T1ClearPerformanceCounterLocal | read-write | current | Local FRM220-GFOM04/08 card E1/T1 Clear Performance Counter GFOM04:1-4 GFOM08:1-8 |
| 1.3.6.1.4.1.4756.20.470.20.1.98 | ColumngfomOrderWirePhoneRingLocal | read-only | current | Local FRM220-GFOM04/08 card Order Wire Phone Ring : 0:None 1:Ring |
| 1.3.6.1.4.1.4756.20.470.20.1.99 | ColumngfomOrderWireTypeLocal | read-only | current | Local FRM220-GFOM04/08 card Order Wire Type : 1:2-Wire 2:4-Wire 3:Empty |
| 1.3.6.1.4.1.4756.20.470.20.1.100 | ColumngfomOrderWireActiveLocal | read-write | current | Local FRM220-GFOM04/08 card Order Wire Active : 0:Disable 1:Enable |
| 1.3.6.1.4.1.4756.20.470.20.1.101 | ColumngfomAlarmStatusLocal | read-only | current | Local FRM220-GFOM04/08 card Alarm Status : 0:None 1:Alarm |
| 1.3.6.1.4.1.4756.20.470.20.1.102 | ColumngfomAlarmBuzzerStatusLocal | read-only | current | Local FRM220-GFOM04/08 card Alarm Buzzer Status : 0:Normal 1:Buzzer |
| 1.3.6.1.4.1.4756.20.470.20.1.103 | ColumngfomAlarmRDIStatusLocal | read-only | current | Local FRM220-GFOM04/08 card Alarm RDI Status : 0:None 1:Remote Alarm |
| 1.3.6.1.4.1.4756.20.470.20.1.104 | ColumngfomAlarmBuzzerLocal | read-write | current | Local FRM220-GFOM04/08 card Alarm Buzzer Active: 0:Disable 1:Enable |
| 1.3.6.1.4.1.4756.20.470.20.1.105 | ColumngfomAlarmTriggerOpticalLocal | read-write | current | Local FRM220-GFOM04/08 card Alarm Trigger Optical: 0:No 1:Yes |
| 1.3.6.1.4.1.4756.20.470.20.1.106 | ColumngfomAlarmTriggerLANLocal | read-write | current | Local FRM220-GFOM04/08 card Alarm Trigger LAN: 0:No 1:Yes |
| 1.3.6.1.4.1.4756.20.470.20.1.107 | ColumngfomAlarmTriggerRDILocal | read-write | current | Local FRM220-GFOM04/08 card Alarm Trigger RDI: 0:No 1:Yes |
| 1.3.6.1.4.1.4756.20.470.20.1.108 | ColumngfomDeviceActiveLocal | read-write | current | Local FRM220-GFOM04/08 card Device Active: 0:Disable 1:Enable |
| 1.3.6.1.4.1.4756.20.470.20.1.109 | ColumngfomSetDefaultLocal | read-write | current | Force remote FRM220-GFOM04/08 card to default : 0:Off 1:Action |
| 1.3.6.1.4.1.4756.20.470.20.1.110 | ColumngfomPortResetLocal | read-write | current | Force remote FRM220-GFOM04/08 card reset mode: 0:Off 1:Action |
| 1.3.6.1.4.1.4756.20.470.20.1.111 | ColumngfomFx1DDVendorLocal | read-only | current | Local FRM220-GFOM04/08 card fiber1 D/D information: Vendor name |
| 1.3.6.1.4.1.4756.20.470.20.1.112 | ColumngfomFx1DDPartNoLocal | read-only | current | Local FRM220-GFOM04/08 card fiber1 D/D information: Vendor part number |
| 1.3.6.1.4.1.4756.20.470.20.1.113 | ColumngfomFx1DDFiberTypeLocal | read-only | current | Local FRM220-GFOM04/08 card fiber1 D/D information: Fiber Type |
| 1.3.6.1.4.1.4756.20.470.20.1.114 | ColumngfomFx1DDWaveLenLocal | read-only | current | Local FRM220-GFOM04/08 card fiber1 D/D information: Wave length |
| 1.3.6.1.4.1.4756.20.470.20.1.115 | ColumngfomFx1DDWaveLen2Local | read-only | current | Local FRM220-GFOM04/08 card fiber1 D/D information: Wave length 2 |
| 1.3.6.1.4.1.4756.20.470.20.1.116 | ColumngfomFx1DDLinkLenLocal | read-only | current | Local FRM220-GFOM04/08 card fiber1 D/D information: Link length |
| 1.3.6.1.4.1.4756.20.470.20.1.117 | ColumngfomFx1DDLenUnitLocal | read-only | current | Local FRM220-GFOM04/08 card fiber1 D/D information: Length Unit |
| 1.3.6.1.4.1.4756.20.470.20.1.118 | ColumngfomFx1DDStatusLocal | read-only | current | Local FRM220-GFOM04/08 card fiber1 D/D information: Status Support |
| 1.3.6.1.4.1.4756.20.470.20.1.119 | ColumngfomFx1DDRxSensLocal | read-only | current | Local FRM220-GFOM04/08 card fiber1 D/D information: Rx Sensitivity |
| 1.3.6.1.4.1.4756.20.470.20.1.120 | ColumngfomFx1DDTxPwrLocal | read-only | current | Local FRM220-GFOM04/08 card fiber1 D/D information: Tx power |
| 1.3.6.1.4.1.4756.20.470.20.1.121 | ColumngfomFx1DDRxPwrLocal | read-only | current | Local FRM220-GFOM04/08 card fiber1 D/D information: Rx power |
| 1.3.6.1.4.1.4756.20.470.20.1.122 | ColumngfomFx1DDTempLocal | read-only | current | Local FRM220-GFOM04/08 card fiber1 D/D information: Temperature in degree C |
| 1.3.6.1.4.1.4756.20.470.20.1.123 | ColumngfomFx1DDPwrMarginLocal | read-only | current | Local FRM220-GFOM04/08 card fiber1 D/D information: Power margin |
| 1.3.6.1.4.1.4756.20.470.20.1.124 | ColumngfomFx2DDVendorLocal | read-only | current | Local FRM220-GFOM04/08 card fiber2 D/D information: Vendor name |
| 1.3.6.1.4.1.4756.20.470.20.1.125 | ColumngfomFx2DDPartNoLocal | read-only | current | Local FRM220-GFOM04/08 card fiber2 D/D information: Vendor part number |
| 1.3.6.1.4.1.4756.20.470.20.1.126 | ColumngfomFx2DDFiberTypeLocal | read-only | current | Local FRM220-GFOM04/08 card fiber2 D/D information: Fiber Type |
| 1.3.6.1.4.1.4756.20.470.20.1.127 | ColumngfomFx2DDWaveLenLocal | read-only | current | Local FRM220-GFOM04/08 card fiber2 D/D information: Wave length |
| 1.3.6.1.4.1.4756.20.470.20.1.128 | ColumngfomFx2DDWaveLen2Local | read-only | current | Local FRM220-GFOM04/08 card fiber2 D/D information: Wave length 2 |
| 1.3.6.1.4.1.4756.20.470.20.1.129 | ColumngfomFx2DDLinkLenLocal | read-only | current | Local FRM220-GFOM04/08 card fiber2 D/D information: Link length |
| 1.3.6.1.4.1.4756.20.470.20.1.130 | ColumngfomFx2DDLenUnitLocal | read-only | current | Local FRM220-GFOM04/08 card fiber2 D/D information: Length Unit |
| 1.3.6.1.4.1.4756.20.470.20.1.131 | ColumngfomFx2DDStatusLocal | read-only | current | Local FRM220-GFOM04/08 card fiber2 D/D information: Status Support |
| 1.3.6.1.4.1.4756.20.470.20.1.132 | ColumngfomFx2DDRxSensLocal | read-only | current | Local FRM220-GFOM04/08 card fiber2 D/D information: Rx Sensitivity |
| 1.3.6.1.4.1.4756.20.470.20.1.133 | ColumngfomFx2DDTxPwrLocal | read-only | current | Local FRM220-GFOM04/08 card fiber2 D/D information: Tx power |
| 1.3.6.1.4.1.4756.20.470.20.1.134 | ColumngfomFx2DDRxPwrLocal | read-only | current | Local FRM220-GFOM04/08 card fiber2 D/D information: Rx power |
| 1.3.6.1.4.1.4756.20.470.20.1.135 | ColumngfomFx2DDTempLocal | read-only | current | Local FRM220-GFOM04/08 card fiber2 D/D information: Temperature in degree C |
| 1.3.6.1.4.1.4756.20.470.20.1.136 | ColumngfomFx2DDPwrMarginLocal | read-only | current | Local FRM220-GFOM04/08 card fiber2 D/D information: Power margin |
| 1.3.6.1.4.1.4756.20.470.20.1.137 | ColumngfomRemotePowerLocal | read-only | current | Local FRM220-GFOM04 Remote power fail: 0:Ok 1:Abnormal |
| 1.3.6.1.4.1.4756.20.470.20.1.138 | ColumngfomFEFLocal | read-only | current | Local FRM220-GFOM04 FEF: 0:Off 1:Detected |
| 1.3.6.1.4.1.4756.20.471 | NodegfomRemoteCards | |||
| 1.3.6.1.4.1.4756.20.471.20 | TablegfomRemoteTable | not-accessible | current | A list of Remote FRM220-GFOM04/08 card entries. |
| 1.3.6.1.4.1.4756.20.471.20.1 | RowgfomRemoteEntry | not-accessible | current | An entry containing management information applicable to a particular Remote FRM220-GFOM04/08 card. |
| 1.3.6.1.4.1.4756.20.471.20.1.1 | ColumngfomChassisIndexRemote | read-only | current | A unique value for each Remote card. It is the chassis location number. |
| 1.3.6.1.4.1.4756.20.471.20.1.2 | ColumngfomSlotIndexRemote | read-only | current | A unique value for each Remote card. It is the slot location number. |
| 1.3.6.1.4.1.4756.20.471.20.1.3 | ColumngfomCardHWVerRemote | read-only | current | Remote FRM220-GFOM04/08 card hardware version x.xxx |
| 1.3.6.1.4.1.4756.20.471.20.1.4 | ColumngfomCardFWVerRemote | read-only | current | Remote FRM220-GFOM04/08 card firmware version x.xxx |
| 1.3.6.1.4.1.4756.20.471.20.1.5 | ColumngfomCardCPLDVerRemote | read-only | current | Remote FRM220-GFOM04/08 card CPLD version x.xxx |
| 1.3.6.1.4.1.4756.20.471.20.1.6 | ColumngfomCardFPGAVerRemote | read-only | current | Remote FRM220-GFOM04/08 card FPGA version x.xxx |
| 1.3.6.1.4.1.4756.20.471.20.1.7 | ColumngfomModelRemote | read-only | current | Remote FRM220-GFOM04/08 Mode: 0:FRM220-GFOM04 1:FRM220-GFOM08 2:FMUX800 |
| 1.3.6.1.4.1.4756.20.471.20.1.8 | ColumngfomFx1LinkRemote | read-only | current | Remote FRM220-GFOM04/08 card fiber1 link state: 0:Link Down 1:Link Up |
| 1.3.6.1.4.1.4756.20.471.20.1.9 | ColumngfomFx1TypeRemote | read-only | current | Remote FRM220-GFOM04/08 card fiber1 fiber type: 0:1*9 1:SFP |
| 1.3.6.1.4.1.4756.20.471.20.1.10 | ColumngfomFx1TxFaultRemote | read-only | current | Remote FRM220-GFOM04/08 card fiber1 Tx fault: 0:Normal 1:Fault |
| 1.3.6.1.4.1.4756.20.471.20.1.11 | ColumngfomFx1DDRemote | read-only | current | Remote FRM220-GFOM04/08 card fiber1 Digital Diagnostic function: 0:No 1:Yes |
| 1.3.6.1.4.1.4756.20.471.20.1.12 | ColumngfomFx2LinkRemote | read-only | current | Remote FRM220-GFOM04/08 card fiber2 link state: 0:Link Down 1:Link Up |
| 1.3.6.1.4.1.4756.20.471.20.1.13 | ColumngfomFx2TypeRemote | read-only | current | Remote FRM220-GFOM04/08 card fiber2 type: 0:1*9 1:SFP |
| 1.3.6.1.4.1.4756.20.471.20.1.14 | ColumngfomFx2TxFaultRemote | read-only | current | Remote FRM220-GFOM04/08 card fiber2 Tx fault: 0:Normal 1:Fault |
| 1.3.6.1.4.1.4756.20.471.20.1.15 | ColumngfomFx2DDRemote | read-only | current | Remote FRM220-GFOM04/08 fiber2 Digital Diagnostic function: 0:No 1:Yes |
| 1.3.6.1.4.1.4756.20.471.20.1.16 | ColumngfomFxWorkingPathRemote | read-only | current | Remote FRM220-GFOM04/08 card Fx Working Path Status: 0:OP1 1:OP2 |
| 1.3.6.1.4.1.4756.20.471.20.1.17 | ColumngfomFxBitErrorCounterRemote | read-only | current | Remote FRM220-GFOM04/08 card Fx Bit Error Counter |
| 1.3.6.1.4.1.4756.20.471.20.1.18 | ColumngfomFxProtectionModeRemote | read-write | current | Remote FRM220-GFOM04/08 card Fx Protection Mode: 0:Auto, Non-Revert 1:Auto, Revert 2:Manual Fx1 3:Manual Fx2 |
| 1.3.6.1.4.1.4756.20.471.20.1.19 | ColumngfomFxALSRemote | read-write | current | Remote FRM220-GFOM04/08 card Fx Auto Laser Shutdown : 0:Disable 1:Enable |
| 1.3.6.1.4.1.4756.20.471.20.1.20 | ColumngfomFxLoopbackTestRemote | read-only | current | Remote FRM220-GFOM04/08 card Fx Loopback Test: 0:Disable |
| 1.3.6.1.4.1.4756.20.471.20.1.21 | ColumngfomFxInserOneErrorBitRemote | read-write | current | Remote FRM220-GFOM04/08 card Fx Bert Insert One Bit Error: 0:Off 1:Action |
| 1.3.6.1.4.1.4756.20.471.20.1.22 | ColumngfomFxClearBitErrorCounterRemote | read-write | current | Remote FRM220-GFOM04/08 card Fx Clear Bit Error Counter: 0:Off 1:Action |
| 1.3.6.1.4.1.4756.20.471.20.1.23 | ColumngfomUTPLinkStatusRemote | read-only | current | Remote FRM220-GFOM04/08 card UTP link state: 0:Link Down 1:Link Up |
| 1.3.6.1.4.1.4756.20.471.20.1.24 | ColumngfomUTPSpeedStatusRemote | read-only | current | Remote FRM220-GFOM04/08 card UTP speed state |
| 1.3.6.1.4.1.4756.20.471.20.1.25 | ColumngfomUTPDuplexStatusRemote | read-only | current | Remote FRM220-GFOM04/08 card UTP duplex state |
| 1.3.6.1.4.1.4756.20.471.20.1.26 | ColumngfomUTPPortActiveRemote | read-write | current | Remote FRM220-GFOM04/08 card UTP Port Active : 0:Disable 1:Enable |
| 1.3.6.1.4.1.4756.20.471.20.1.27 | ColumngfomUTPNegotiationRemote | read-write | current | Remote FRM220-GFOM04/08 card UTP Negotiation : 0:Auto 1:Manual |
| 1.3.6.1.4.1.4756.20.471.20.1.28 | ColumngfomUTPSpeedConfRemote | read-write | current | Remote FRM220-GFOM04/08 card UTP Speed : 0:10M 1:100M 2:1000M |
| 1.3.6.1.4.1.4756.20.471.20.1.29 | ColumngfomUTPDuplexConfRemote | read-write | current | Remote FRM220-GFOM04/08 card UTP Duplex : 0:Half 1:Full |
| 1.3.6.1.4.1.4756.20.471.20.1.30 | ColumngfomUTPFlowControlRemote | read-write | current | Remote FRM220-GFOM04/08 card UTP Flow Control : 0:Disable 1:Enable |
| 1.3.6.1.4.1.4756.20.471.20.1.31 | ColumngfomUTPJumboFrameRemote | read-write | current | Remote FRM220-GFOM04/08 card UTP Jumbo Frame : 0:Disable 1:Enable |
| 1.3.6.1.4.1.4756.20.471.20.1.32 | ColumngfomE1T1ModeRemote | read-write | current | Remote FRM220-GFOM04/08 card E1/T1 Mode : 0:E1 (75 ohm) 1:E1 (120 ohm) 2:T1 (100 ohm) |
| 1.3.6.1.4.1.4756.20.471.20.1.33 | ColumngfomE1T1Channel1LinkStatusRemote | read-only | current | Remote FRM220-GFOM04/08 card E1/T1 Channel 1 Link Status |
| 1.3.6.1.4.1.4756.20.471.20.1.34 | ColumngfomE1T1Channel1AISStatusRemote | read-only | current | Remote FRM220-GFOM04/08 card E1/T1 Channel 1 AIS Status |
| 1.3.6.1.4.1.4756.20.471.20.1.35 | ColumngfomE1T1Channel1TxDriverFailureRemote | read-only | current | Remote FRM220-GFOM04/08 card E1/T1 Channel 1 Tx Driver Failure |
| 1.3.6.1.4.1.4756.20.471.20.1.36 | ColumngfomE1T1Channel1PerformanceRemote | read-only | current | Remote FRM220-GFOM04/08 card E1/T1 Channel 1 Performance |
| 1.3.6.1.4.1.4756.20.471.20.1.37 | ColumngfomE1T1Channel1ActiveRemote | read-write | current | Remote FRM220-GFOM04/08 card E1/T1 Channel 1 Active : 0:Disable 1:Enable |
| 1.3.6.1.4.1.4756.20.471.20.1.38 | ColumngfomE1T1Channel1LinCodeRemote | read-write | current | Remote FRM220-GFOM04/08 card E1/T1 Channel 1 Line Code : 0:HDB3/B8ZS 1:AMI |
| 1.3.6.1.4.1.4756.20.471.20.1.39 | ColumngfomE1T1Channel1AutoAISRemote | read-write | current | Remote FRM220-GFOM04/08 card E1/T1 Channel 1 Auto AIS : 0:Disable 1:Enable |
| 1.3.6.1.4.1.4756.20.471.20.1.40 | ColumngfomE1T1Channel1LoopBackRemote | read-write | current | Remote FRM220-GFOM04/08 card E1/T1 Channel 1 Loopback Test : 0:Disable 1:LLB 2:RLB 3:RRLB |
| 1.3.6.1.4.1.4756.20.471.20.1.41 | ColumngfomE1T1Channel2LinkStatusRemote | read-only | current | Remote FRM220-GFOM04/08 card E1/T1 Channel 2 Link Status |
| 1.3.6.1.4.1.4756.20.471.20.1.42 | ColumngfomE1T1Channel2AISStatusRemote | read-only | current | Remote FRM220-GFOM04/08 card E1/T1 Channel 2 AIS Status |
| 1.3.6.1.4.1.4756.20.471.20.1.43 | ColumngfomE1T1Channel2TxDriverFailureRemote | read-only | current | Remote FRM220-GFOM04/08 card E1/T1 Channel 2 Tx Driver Failure |
| 1.3.6.1.4.1.4756.20.471.20.1.44 | ColumngfomE1T1Channel2PerformanceRemote | read-only | current | Remote FRM220-GFOM04/08 card E1/T1 Channel 2 Performance |
| 1.3.6.1.4.1.4756.20.471.20.1.45 | ColumngfomE1T1Channel2ActiveRemote | read-write | current | Remote FRM220-GFOM04/08 card E1/T1 Channel 2 Active : 0:Disable 1:Enable |
| 1.3.6.1.4.1.4756.20.471.20.1.46 | ColumngfomE1T1Channel2LinCodeRemote | read-write | current | Remote FRM220-GFOM04/08 card E1/T1 Channel 2 Line Code : 0:HDB3/B8ZS 1:AMI |
| 1.3.6.1.4.1.4756.20.471.20.1.47 | ColumngfomE1T1Channel2AutoAISRemote | read-write | current | Remote FRM220-GFOM04/08 card E1/T1 Channel 2 Auto AIS : 0:Disable 1:Enable |
| 1.3.6.1.4.1.4756.20.471.20.1.48 | ColumngfomE1T1Channel2LoopBackRemote | read-write | current | Remote FRM220-GFOM04/08 card E1/T1 Channel 2 Loopback Test : 0:Disable 1:LLB 2:RLB 3:RRLB |
| 1.3.6.1.4.1.4756.20.471.20.1.49 | ColumngfomE1T1Channel3LinkStatusRemote | read-only | current | Remote FRM220-GFOM04/08 card E1/T1 Channel 3 Link Status |
| 1.3.6.1.4.1.4756.20.471.20.1.50 | ColumngfomE1T1Channel3AISStatusRemote | read-only | current | Remote FRM220-GFOM04/08 card E1/T1 Channel 3 AIS Status |
| 1.3.6.1.4.1.4756.20.471.20.1.51 | ColumngfomE1T1Channel3TxDriverFailureRemote | read-only | current | Remote FRM220-GFOM04/08 card E1/T1 Channel 3 Tx Driver Failure |
| 1.3.6.1.4.1.4756.20.471.20.1.52 | ColumngfomE1T1Channel3PerformanceRemote | read-only | current | Remote FRM220-GFOM04/08 card E1/T1 Channel 3 Performance |
| 1.3.6.1.4.1.4756.20.471.20.1.53 | ColumngfomE1T1Channel3ActiveRemote | read-write | current | Remote FRM220-GFOM04/08 card E1/T1 Channel 3 Active : 0:Disable 1:Enable |
| 1.3.6.1.4.1.4756.20.471.20.1.54 | ColumngfomE1T1Channel3LinCodeRemote | read-write | current | Remote FRM220-GFOM04/08 card E1/T1 Channel 3 Line Code : 0:HDB3/B8ZS 1:AMI |
| 1.3.6.1.4.1.4756.20.471.20.1.55 | ColumngfomE1T1Channel3AutoAISRemote | read-write | current | Remote FRM220-GFOM04/08 card E1/T1 Channel 3 Auto AIS : 0:Disable 1:Enable |
| 1.3.6.1.4.1.4756.20.471.20.1.56 | ColumngfomE1T1Channel3LoopBackRemote | read-write | current | Remote FRM220-GFOM04/08 card E1/T1 Channel 3 Loopback Test : 0:Disable 1:LLB 2:RLB 3:RRLB |
| 1.3.6.1.4.1.4756.20.471.20.1.57 | ColumngfomE1T1Channel4LinkStatusRemote | read-only | current | Remote FRM220-GFOM04/08 card E1/T1 Channel 4 Link Status |
| 1.3.6.1.4.1.4756.20.471.20.1.58 | ColumngfomE1T1Channel4AISStatusRemote | read-only | current | Remote FRM220-GFOM04/08 card E1/T1 Channel 4 AIS Status |
| 1.3.6.1.4.1.4756.20.471.20.1.59 | ColumngfomE1T1Channel4TxDriverFailureRemote | read-only | current | Remote FRM220-GFOM04/08 card E1/T1 Channel 4 Tx Driver Failure |
| 1.3.6.1.4.1.4756.20.471.20.1.60 | ColumngfomE1T1Channel4PerformanceRemote | read-only | current | Remote FRM220-GFOM04/08 card E1/T1 Channel 4 Performance |
| 1.3.6.1.4.1.4756.20.471.20.1.61 | ColumngfomE1T1Channel4ActiveRemote | read-write | current | Remote FRM220-GFOM04/08 card E1/T1 Channel 4 Active : 0:Disable 1:Enable |
| 1.3.6.1.4.1.4756.20.471.20.1.62 | ColumngfomE1T1Channel4LinCodeRemote | read-write | current | Remote FRM220-GFOM04/08 card E1/T1 Channel 4 Line Code : 0:HDB3/B8ZS 1:AMI |
| 1.3.6.1.4.1.4756.20.471.20.1.63 | ColumngfomE1T1Channel4AutoAISRemote | read-write | current | Remote FRM220-GFOM04/08 card E1/T1 Channel 4 Auto AIS : 0:Disable 1:Enable |
| 1.3.6.1.4.1.4756.20.471.20.1.64 | ColumngfomE1T1Channel4LoopBackRemote | read-write | current | Remote FRM220-GFOM04/08 card E1/T1 Channel 4 Loopback Test : 0:Disable 1:LLB 2:RLB 3:RRLB |
| 1.3.6.1.4.1.4756.20.471.20.1.65 | ColumngfomE1T1Channel5LinkStatusRemote | read-only | current | Remote FRM220-GFOM04/08 card E1/T1 Channel 5 Link Status |
| 1.3.6.1.4.1.4756.20.471.20.1.66 | ColumngfomE1T1Channel5AISStatusRemote | read-only | current | Remote FRM220-GFOM04/08 card E1/T1 Channel 5 AIS Status |
| 1.3.6.1.4.1.4756.20.471.20.1.67 | ColumngfomE1T1Channel5TxDriverFailureRemote | read-only | current | Remote FRM220-GFOM04/08 card E1/T1 Channel 5 Tx Driver Failure |
| 1.3.6.1.4.1.4756.20.471.20.1.68 | ColumngfomE1T1Channel5PerformanceRemote | read-only | current | Remote FRM220-GFOM04/08 card E1/T1 Channel 5 Performance |
| 1.3.6.1.4.1.4756.20.471.20.1.69 | ColumngfomE1T1Channel5ActiveRemote | read-write | current | Remote FRM220-GFOM04/08 card E1/T1 Channel 5 Active : 0:Disable 1:Enable |
| 1.3.6.1.4.1.4756.20.471.20.1.70 | ColumngfomE1T1Channel5LinCodeRemote | read-write | current | Remote FRM220-GFOM04/08 card E1/T1 Channel 5 Line Code : 0:HDB3/B8ZS 1:AMI |
| 1.3.6.1.4.1.4756.20.471.20.1.71 | ColumngfomE1T1Channel5AutoAISRemote | read-write | current | Remote FRM220-GFOM04/08 card E1/T1 Channel5 Auto AIS : 0:Disable 1:Enable |
| 1.3.6.1.4.1.4756.20.471.20.1.72 | ColumngfomE1T1Channel5LoopBackRemote | read-write | current | Remote FRM220-GFOM04/08 card E1/T1 Channel 5 Loopback Test : 0:Disable 1:LLB 2:RLB 3:RRLB |
| 1.3.6.1.4.1.4756.20.471.20.1.73 | ColumngfomE1T1Channel6LinkStatusRemote | read-only | current | Remote FRM220-GFOM04/08 card E1/T1 Channel 6 Link Status |
| 1.3.6.1.4.1.4756.20.471.20.1.74 | ColumngfomE1T1Channel6AISStatusRemote | read-only | current | Remote FRM220-GFOM04/08 card E1/T1 Channel 6 AIS Status |
| 1.3.6.1.4.1.4756.20.471.20.1.75 | ColumngfomE1T1Channel6TxDriverFailureRemote | read-only | current | Remote FRM220-GFOM04/08 card E1/T1 Channel 6 Tx Driver Failure |
| 1.3.6.1.4.1.4756.20.471.20.1.76 | ColumngfomE1T1Channel6PerformanceRemote | read-only | current | Remote FRM220-GFOM04/08 card E1/T1 Channel 6 Performance |
| 1.3.6.1.4.1.4756.20.471.20.1.77 | ColumngfomE1T1Channel6ActiveRemote | read-write | current | Remote FRM220-GFOM04/08 card E1/T1 Channel 6 Active : 0:Disable 1:Enable |
| 1.3.6.1.4.1.4756.20.471.20.1.78 | ColumngfomE1T1Channel6LinCodeRemote | read-write | current | Remote FRM220-GFOM04/08 card E1/T1 Channel 6 Line Code : 0:HDB3/B8ZS 1:AMI |
| 1.3.6.1.4.1.4756.20.471.20.1.79 | ColumngfomE1T1Channel6AutoAISRemote | read-write | current | Remote FRM220-GFOM04/08 card E1/T1 Channel 6 Auto AIS : 0:Disable 1:Enable |
| 1.3.6.1.4.1.4756.20.471.20.1.80 | ColumngfomE1T1Channel6LoopBackRemote | read-write | current | Remote FRM220-GFOM04/08 card E1/T1 Channel 6 Loopback Test : 0:Disable 1:LLB 2:RLB 3:RRLB |
| 1.3.6.1.4.1.4756.20.471.20.1.81 | ColumngfomE1T1Channel7LinkStatusRemote | read-only | current | Remote FRM220-GFOM04/08 card E1/T1 Channel 7 Link Status |
| 1.3.6.1.4.1.4756.20.471.20.1.82 | ColumngfomE1T1Channel7AISStatusRemote | read-only | current | Remote FRM220-GFOM04/08 card E1/T1 Channel 7 AIS Status |
| 1.3.6.1.4.1.4756.20.471.20.1.83 | ColumngfomE1T1Channel7TxDriverFailureRemote | read-only | current | Remote FRM220-GFOM04/08 card E1/T1 Channel 7 Tx Driver Failure |
| 1.3.6.1.4.1.4756.20.471.20.1.84 | ColumngfomE1T1Channel7PerformanceRemote | read-only | current | Remote FRM220-GFOM04/08 card E1/T1 Channel 7 Performance |
| 1.3.6.1.4.1.4756.20.471.20.1.85 | ColumngfomE1T1Channel7ActiveRemote | read-write | current | Remote FRM220-GFOM04/08 card E1/T1 Channel 7 Active : 0:Disable 1:Enable |
| 1.3.6.1.4.1.4756.20.471.20.1.86 | ColumngfomE1T1Channel7LinCodeRemote | read-write | current | Remote FRM220-GFOM04/08 card E1/T1 Channel 7 Line Code : 0:HDB3/B8ZS 1:AMI |
| 1.3.6.1.4.1.4756.20.471.20.1.87 | ColumngfomE1T1Channel7AutoAISRemote | read-write | current | Remote FRM220-GFOM04/08 card E1/T1 Channel 7 Auto AIS : 0:Disable 1:Enable |
| 1.3.6.1.4.1.4756.20.471.20.1.88 | ColumngfomE1T1Channel7LoopBackRemote | read-write | current | Remote FRM220-GFOM04/08 card E1/T1 Channel 7 Loopback Test : 0:Disable 1:LLB 2:RLB 3:RRLB |
| 1.3.6.1.4.1.4756.20.471.20.1.89 | ColumngfomE1T1Channel8LinkStatusRemote | read-only | current | Remote FRM220-GFOM04/08 card E1/T1 Channel 8 Link Status |
| 1.3.6.1.4.1.4756.20.471.20.1.90 | ColumngfomE1T1Channel8AISStatusRemote | read-only | current | Remote FRM220-GFOM04/08 card E1/T1 Channel 8 AIS Status |
| 1.3.6.1.4.1.4756.20.471.20.1.91 | ColumngfomE1T1Channel8TxDriverFailureRemote | read-only | current | Remote FRM220-GFOM04/08 card E1/T1 Channel 8 Tx Driver Failure |
| 1.3.6.1.4.1.4756.20.471.20.1.92 | ColumngfomE1T1Channel8PerformanceRemote | read-only | current | Remote FRM220-GFOM04/08 card E1/T1 Channel 8 Performance |
| 1.3.6.1.4.1.4756.20.471.20.1.93 | ColumngfomE1T1Channel8ActiveRemote | read-write | current | Remote FRM220-GFOM04/08 card E1/T1 Channel 8 Active : 0:Disable 1:Enable |
| 1.3.6.1.4.1.4756.20.471.20.1.94 | ColumngfomE1T1Channel8LinCodeRemote | read-write | current | Remote FRM220-GFOM04/08 card E1/T1 Channel 8 Line Code : 0:HDB3/B8ZS 1:AMI |
| 1.3.6.1.4.1.4756.20.471.20.1.95 | ColumngfomE1T1Channel8AutoAISRemote | read-write | current | Remote FRM220-GFOM04/08 card E1/T1 Channel 8 Auto AIS : 0:Disable 1:Enable |
| 1.3.6.1.4.1.4756.20.471.20.1.96 | ColumngfomE1T1Channel8LoopBackRemote | read-write | current | Remote FRM220-GFOM04/08 card E1/T1 Channel 8 Loopback Test : 0:Disable 1:LLB 2:RLB 3:RRLB |
| 1.3.6.1.4.1.4756.20.471.20.1.97 | ColumngfomE1T1ClearPerformanceCounterRemote | read-write | current | Remote FRM220-GFOM04/08 card E1/T1 Clear Performance Counter GFOM04:1-4 GFOM08:1-8 |
| 1.3.6.1.4.1.4756.20.471.20.1.98 | ColumngfomOrderWirePhoneRingRemote | read-only | current | Remote FRM220-GFOM04/08 card Order Wire Phone Ring : 0:None 1:Ring |
| 1.3.6.1.4.1.4756.20.471.20.1.99 | ColumngfomOrderWireTypeRemote | read-only | current | Remote FRM220-GFOM04/08 card Order Wire Type : 1:2-Wire 2:4-Wire 3:Empty |
| 1.3.6.1.4.1.4756.20.471.20.1.100 | ColumngfomOrderWireActiveRemote | read-write | current | Remote FRM220-GFOM04/08 card Order Wire Active : 0:Disable 1:Enable |
| 1.3.6.1.4.1.4756.20.471.20.1.101 | ColumngfomAlarmStatusRemote | read-only | current | Remote FRM220-GFOM04/08 card Alarm Status : 0:None 1:Alarm |
| 1.3.6.1.4.1.4756.20.471.20.1.102 | ColumngfomAlarmBuzzerStatusRemote | read-only | current | Remote FRM220-GFOM04/08 card Alarm Buzzer Status : 0:Normal 1:Buzzer |
| 1.3.6.1.4.1.4756.20.471.20.1.103 | ColumngfomAlarmRDIStatusRemote | read-only | current | Remote FRM220-GFOM04/08 card Alarm RDI Status : 0:None 1:Remote Alarm |
| 1.3.6.1.4.1.4756.20.471.20.1.104 | ColumngfomAlarmBuzzerRemote | read-write | current | Remote FRM220-GFOM04/08 card Alarm Buzzer Active: 0:Disable 1:Enable |
| 1.3.6.1.4.1.4756.20.471.20.1.105 | ColumngfomAlarmTriggerOpticalRemote | read-write | current | Remote FRM220-GFOM04/08 card Alarm Trigger Optical: 0:No 1:Yes |
| 1.3.6.1.4.1.4756.20.471.20.1.106 | ColumngfomAlarmTriggerLANRemote | read-write | current | Remote FRM220-GFOM04/08 card Alarm Trigger LAN: 0:No 1:Yes |
| 1.3.6.1.4.1.4756.20.471.20.1.107 | ColumngfomAlarmTriggerRDIRemote | read-write | current | Remote FRM220-GFOM04/08 card Alarm Trigger RDI: 0:No 1:Yes |
| 1.3.6.1.4.1.4756.20.471.20.1.108 | ColumngfomDeviceActiveRemote | read-only | current | Remote FRM220-GFOM04/08 card Device Active: 0:Disable 1:Enable |
| 1.3.6.1.4.1.4756.20.471.20.1.109 | ColumngfomSetDefaultRemote | read-write | current | Force remote FRM220-GFOM04/08 card to default : 0:Off 1:Action |
| 1.3.6.1.4.1.4756.20.471.20.1.110 | ColumngfomPortResetRemote | read-write | current | Force remote FRM220-GFOM04/08 card reset mode: 0:Off 1:Action |
| 1.3.6.1.4.1.4756.20.471.20.1.111 | ColumngfomFx1DDVendorRemote | read-only | current | Remote FRM220-GFOM04/08 card fiber1 D/D information: Vendor name |
| 1.3.6.1.4.1.4756.20.471.20.1.112 | ColumngfomFx1DDPartNoRemote | read-only | current | Remote FRM220-GFOM04/08 card fiber1 D/D information: Vendor part number |
| 1.3.6.1.4.1.4756.20.471.20.1.113 | ColumngfomFx1DDFiberTypeRemote | read-only | current | Remote FRM220-GFOM04/08 card fiber1 D/D information: Fiber Type |
| 1.3.6.1.4.1.4756.20.471.20.1.114 | ColumngfomFx1DDWaveLenRemote | read-only | current | Remote FRM220-GFOM04/08 card fiber1 D/D information: Wave length |
| 1.3.6.1.4.1.4756.20.471.20.1.115 | ColumngfomFx1DDWaveLen2Remote | read-only | current | Remote FRM220-GFOM04/08 card fiber1 D/D information: Wave length 2 |
| 1.3.6.1.4.1.4756.20.471.20.1.116 | ColumngfomFx1DDLinkLenRemote | read-only | current | Remote FRM220-GFOM04/08 card fiber1 D/D information: Link length |
| 1.3.6.1.4.1.4756.20.471.20.1.117 | ColumngfomFx1DDLenUnitRemote | read-only | current | Remote FRM220-GFOM04/08 card fiber1 D/D information: Length Unit |
| 1.3.6.1.4.1.4756.20.471.20.1.118 | ColumngfomFx1DDStatusRemote | read-only | current | Remote FRM220-GFOM04/08 card fiber1 D/D information: Status Support |
| 1.3.6.1.4.1.4756.20.471.20.1.119 | ColumngfomFx1DDRxSensRemote | read-only | current | Remote FRM220-GFOM04/08 card fiber1 D/D information: Rx Sensitivity |
| 1.3.6.1.4.1.4756.20.471.20.1.120 | ColumngfomFx1DDTxPwrRemote | read-only | current | Remote FRM220-GFOM04/08 card fiber1 D/D information: Tx power |
| 1.3.6.1.4.1.4756.20.471.20.1.121 | ColumngfomFx1DDRxPwrRemote | read-only | current | Remote FRM220-GFOM04/08 card fiber1 D/D information: Rx power |
| 1.3.6.1.4.1.4756.20.471.20.1.122 | ColumngfomFx1DDTempRemote | read-only | current | Remote FRM220-GFOM04/08 card fiber1 D/D information: Temperature in degree C |
| 1.3.6.1.4.1.4756.20.471.20.1.123 | ColumngfomFx1DDPwrMarginRemote | read-only | current | Remote FRM220-GFOM04/08 card fiber1 D/D information: Power margin |
| 1.3.6.1.4.1.4756.20.471.20.1.124 | ColumngfomFx2DDVendorRemote | read-only | current | Remote FRM220-GFOM04/08 card fiber2 D/D information: Vendor name |
| 1.3.6.1.4.1.4756.20.471.20.1.125 | ColumngfomFx2DDPartNoRemote | read-only | current | Remote FRM220-GFOM04/08 card fiber2 D/D information: Vendor part number |
| 1.3.6.1.4.1.4756.20.471.20.1.126 | ColumngfomFx2DDFiberTypeRemote | read-only | current | Remote FRM220-GFOM04/08 card fiber2 D/D information: Fiber Type |
| 1.3.6.1.4.1.4756.20.471.20.1.127 | ColumngfomFx2DDWaveLenRemote | read-only | current | Remote FRM220-GFOM04/08 card fiber2 D/D information: Wave length |
| 1.3.6.1.4.1.4756.20.471.20.1.128 | ColumngfomFx2DDWaveLen2Remote | read-only | current | Remote FRM220-GFOM04/08 card fiber2 D/D information: Wave length 2 |
| 1.3.6.1.4.1.4756.20.471.20.1.129 | ColumngfomFx2DDLinkLenRemote | read-only | current | Remote FRM220-GFOM04/08 card fiber2 D/D information: Link length |
| 1.3.6.1.4.1.4756.20.471.20.1.130 | ColumngfomFx2DDLenUnitRemote | read-only | current | Remote FRM220-GFOM04/08 card fiber2 D/D information: Length Unit |
| 1.3.6.1.4.1.4756.20.471.20.1.131 | ColumngfomFx2DDStatusRemote | read-only | current | Remote FRM220-GFOM04/08 card fiber2 D/D information: Status Support |
| 1.3.6.1.4.1.4756.20.471.20.1.132 | ColumngfomFx2DDRxSensRemote | read-only | current | Remote FRM220-GFOM04/08 card fiber2 D/D information: Rx Sensitivity |
| 1.3.6.1.4.1.4756.20.471.20.1.133 | ColumngfomFx2DDTxPwrRemote | read-only | current | Remote FRM220-GFOM04/08 card fiber2 D/D information: Tx power |
| 1.3.6.1.4.1.4756.20.471.20.1.134 | ColumngfomFx2DDRxPwrRemote | read-only | current | Remote FRM220-GFOM04/08 card fiber2 D/D information: Rx power |
| 1.3.6.1.4.1.4756.20.471.20.1.135 | ColumngfomFx2DDTempRemote | read-only | current | Remote FRM220-GFOM04/08 card fiber2 D/D information: Temperature in degree C |
| 1.3.6.1.4.1.4756.20.471.20.1.136 | ColumngfomFx2DDPwrMarginRemote | read-only | current | Remote FRM220-GFOM04/08 card fiber2 D/D information: Power margin |
| 1.3.6.1.4.1.4756.20.471.20.1.137 | ColumngfomRemotePowerRemote | read-only | current | Remote FRM220-GFOM04 Remote power fail: 0:Ok 1:Abnormal |
| 1.3.6.1.4.1.4756.20.471.20.1.138 | ColumngfomFEFRemote | read-only | current | Remote FRM220-GFOM04 FEF: 0:Off 1:Detected |
| 1.3.6.1.4.1.4756.20.471.20.1.139 | ColumngfomPower1TypeRemote | read-only | current | Remote FMUX800 Power1 Type: 0:None 1:DV-24V 2:DV-48V 3:AC 4:Empty |
| 1.3.6.1.4.1.4756.20.471.20.1.140 | ColumngfomPower1StatusRemote | read-only | current | Remote FMUX800 Power1 Status: 0:Abnormal 1:OK |
| 1.3.6.1.4.1.4756.20.471.20.1.141 | ColumngfomPower2TypeRemote | read-only | current | Remote FMUX800 Power2 Type: 0:None 1:DV-24V 2:DV-48V 3:AC 4:Empty |
| 1.3.6.1.4.1.4756.20.471.20.1.142 | ColumngfomPower2StatusRemote | read-only | current | Remote FMUX800 Power2 Status: 0:Abnormal 1:OK |
| 1.3.6.1.4.1.4756.20.471.20.1.143 | ColumngfomUTP1LinkStatusRemote | read-only | current | Remote FMUX800 card UTP1 link state: 0:Link Down 1:Link Up |
| 1.3.6.1.4.1.4756.20.471.20.1.144 | ColumngfomUTP1SpeedStatusRemote | read-only | current | Remote FMUX800 card UTP1 speed state |
| 1.3.6.1.4.1.4756.20.471.20.1.145 | ColumngfomUTP1DuplexStatusRemote | read-only | current | Remote FMUX800 card UTP1 duplex state |
| 1.3.6.1.4.1.4756.20.471.20.1.146 | ColumngfomUTP1PortActiveRemote | read-write | current | Remote FMUX800 card UTP1 Port Active : 0:Disable 1:Enable |
| 1.3.6.1.4.1.4756.20.471.20.1.147 | ColumngfomUTP1NegotiationRemote | read-write | current | Remote FMUX800 card UTP1 Negotiation : 0:Auto 1:Manual |
| 1.3.6.1.4.1.4756.20.471.20.1.148 | ColumngfomUTP1SpeedConfRemote | read-write | current | Remote FMUX800 card UTP1 Speed : 0:10M 1:100M 2:1000M |
| 1.3.6.1.4.1.4756.20.471.20.1.149 | ColumngfomUTP1DuplexConfRemote | read-write | current | Remote FMUX800 card UTP1 Duplex : 0:Half 1:Full |
| 1.3.6.1.4.1.4756.20.471.20.1.150 | ColumngfomUTP2LinkStatusRemote | read-only | current | Remote FMUX800 card UTP2 link state: 0:Link Down 1:Link Up |
| 1.3.6.1.4.1.4756.20.471.20.1.151 | ColumngfomUTP2SpeedStatusRemote | read-only | current | Remote FMUX800 card UTP2 speed state |
| 1.3.6.1.4.1.4756.20.471.20.1.152 | ColumngfomUTP2DuplexStatusRemote | read-only | current | Remote FMUX800 card UTP2 duplex state |
| 1.3.6.1.4.1.4756.20.471.20.1.153 | ColumngfomUTP2PortActiveRemote | read-write | current | Remote FMUX800 card UTP2 Port Active : 0:Disable 1:Enable |
| 1.3.6.1.4.1.4756.20.471.20.1.154 | ColumngfomUTP2NegotiationRemote | read-write | current | Remote FMUX800 card UTP2 Negotiation : 0:Auto 1:Manual |
| 1.3.6.1.4.1.4756.20.471.20.1.155 | ColumngfomUTP2SpeedConfRemote | read-write | current | Remote FMUX800 card UTP3 Speed : 0:10M 1:100M 2:1000M |
| 1.3.6.1.4.1.4756.20.471.20.1.156 | ColumngfomUTP2DuplexConfRemote | read-write | current | Remote FMUX800 card UTP3 Duplex : 0:Half 1:Full |
| 1.3.6.1.4.1.4756.20.471.20.1.157 | ColumngfomUTP3LinkStatusRemote | read-only | current | Remote FMUX800 card UTP3 link state: 0:Link Down 1:Link Up |
| 1.3.6.1.4.1.4756.20.471.20.1.158 | ColumngfomUTP3SpeedStatusRemote | read-only | current | Remote FMUX800 card UTP3 speed state |
| 1.3.6.1.4.1.4756.20.471.20.1.159 | ColumngfomUTP3DuplexStatusRemote | read-only | current | Remote FMUX800 card UTP3 duplex state |
| 1.3.6.1.4.1.4756.20.471.20.1.160 | ColumngfomUTP3PortActiveRemote | read-write | current | Remote FMUX800 card UTP3 Port Active : 0:Disable 1:Enable |
| 1.3.6.1.4.1.4756.20.471.20.1.161 | ColumngfomUTP3NegotiationRemote | read-write | current | Remote FMUX800 card UTP3 Negotiation : 0:Auto 1:Manual |
| 1.3.6.1.4.1.4756.20.471.20.1.162 | ColumngfomUTP3SpeedConfRemote | read-write | current | Remote FMUX800 card UTP3 Speed : 0:10M 1:100M 2:1000M |
| 1.3.6.1.4.1.4756.20.471.20.1.163 | ColumngfomUTP3DuplexConfRemote | read-write | current | Remote FMUX800 card UTP3 Duplex : 0:Half 1:Full |
| 1.3.6.1.4.1.4756.20.471.20.1.164 | ColumngfomUTP4LinkStatusRemote | read-only | current | Remote FMUX800 card UTP4 link state: 0:Link Down 1:Link Up |
| 1.3.6.1.4.1.4756.20.471.20.1.165 | ColumngfomUTP4SpeedStatusRemote | read-only | current | Remote FMUX800 card UTP4 speed state |
| 1.3.6.1.4.1.4756.20.471.20.1.166 | ColumngfomUTP4DuplexStatusRemote | read-only | current | Remote FMUX800 card UTP4 duplex state |
| 1.3.6.1.4.1.4756.20.471.20.1.167 | ColumngfomUTP4PortActiveRemote | read-write | current | Remote FMUX800 card UTP4 Port Active : 0:Disable 1:Enable |
| 1.3.6.1.4.1.4756.20.471.20.1.168 | ColumngfomUTP4NegotiationRemote | read-write | current | Remote FMUX800 card UTP4 Negotiation : 0:Auto 1:Manual |
| 1.3.6.1.4.1.4756.20.471.20.1.169 | ColumngfomUTP4SpeedConfRemote | read-write | current | Remote FMUX800 card UTP4 Speed : 0:10M 1:100M 2:1000M |
| 1.3.6.1.4.1.4756.20.471.20.1.170 | ColumngfomUTP4DuplexConfRemote | read-write | current | Remote FMUX800 card UTP4 Duplex : 0:Half 1:Full |
| 1.3.6.1.4.1.4756.20.471.20.1.171 | ColumngfomAlarmRelayStatusRemote | read-only | current | Remote FMUX800 card Alarm Relay Status : 0:Normal 1:Alarm |
| 1.3.6.1.4.1.4756.20.471.20.1.172 | ColumngfomAlarmRelayRemote | read-write | current | Remote FMUX800 card Alarm Relay Active: 0:Disable 1:Enable |
| 1.3.6.1.4.1.4756.20.471.20.1.173 | ColumngfomAlarmTriggerPowerRemote | read-write | current | Remote FMUX800 card Alarm Trigger Power: 0:No 1:Yes |
| 1.3.6.1.4.1.4756.20.480 | Nodef1000EASX2FLocalCards | |||
| 1.3.6.1.4.1.4756.20.480.40 | Tablef1000EASX2FLocalTable | not-accessible | current | A list of local 1000EAS/X-2F card entries. |
| 1.3.6.1.4.1.4756.20.480.40.1 | Rowf1000EASX2FLocalEntry | not-accessible | current | An entry containing management information applicable to a particular local 1000EAS/X-2F card. |
| 1.3.6.1.4.1.4756.20.480.40.1.1 | Columnf1000EASX2FChassisIndexLocal | read-only | current | A unique value for each chassis ID. For CH20, it is the chassis ID. For CH08, it is always 0. |
| 1.3.6.1.4.1.4756.20.480.40.1.2 | Columnf1000EASX2FSlotIndexLocal | read-only | current | A unique value for each local card. It is the slot location number. |
| 1.3.6.1.4.1.4756.20.480.40.1.3 | Columnf1000EASX2FCardHWVerLocal | read-only | current | Local device card hardware version x.xxx |
| 1.3.6.1.4.1.4756.20.480.40.1.4 | Columnf1000EASX2FCardFWVerLocal | read-only | current | Local device card firmware version x.xxx |
| 1.3.6.1.4.1.4756.20.480.40.1.5 | Columnf1000EASX2FCardCPLDVerLocal | read-only | current | Local device card CPLD version x.xxx |
| 1.3.6.1.4.1.4756.20.480.40.1.6 | Columnf1000EASX2FCardFPGAVerLocal | read-only | current | Local device card FPGA version x.xxx |
| 1.3.6.1.4.1.4756.20.480.40.1.7 | Columnf1000EASX2FModelLocal | read-only | current | Local 1000EAS/X Serial Type |
| 1.3.6.1.4.1.4756.20.480.40.1.8 | Columnf1000EASX2FFiber1LinkLocal | read-only | current | Local device card fiber port 1 link status: 0:Down 1:Up |
| 1.3.6.1.4.1.4756.20.480.40.1.9 | Columnf1000EASX2FFiber1OAMLoopedLocal | read-only | current | Local device card fiber port 1 OAM looped: 0:Off 1:on |
| 1.3.6.1.4.1.4756.20.480.40.1.10 | Columnf1000EASX2FFiber1LBTestLocal | read-write | current | Force remote device card to do fiber port 1 LoopBack testing: 0:Off 1:Action |
| 1.3.6.1.4.1.4756.20.480.40.1.11 | Columnf1000EASX2FFiber1OAMRLBStatusLocal | read-only | current | Remote device card fiber port 1 LoopBack testing status: 0:Off 1:Ok 2:Fail |
| 1.3.6.1.4.1.4756.20.480.40.1.12 | Columnf1000EASX2FFiber1RemoPwrAbLocal | read-only | current | Local device card fiber port 1 Remote Power status: 0:Abnormal 1:OK 2:None |
| 1.3.6.1.4.1.4756.20.480.40.1.13 | Columnf1000EASX2FFiber1IngressRateLocal | read-write | current | Local device card fiber 1 Ingress Rate Limit: 0 = Unlimit input format: 64k(K),100m(M),100 If doesn't input the unit, the default was Mega. Limite Rate : 64K ~… |
| 1.3.6.1.4.1.4756.20.480.40.1.14 | Columnf1000EASX2FFiber1EgressRateLocal | read-write | current | Local device card fiber 1 Egress Rate Limit: 0 = Unlimit input format: 64k(K),100m(M),100 If doesn't input the unit, the default was Mega. Limite Rate : 64K ~ … |
| 1.3.6.1.4.1.4756.20.480.40.1.15 | Columnf1000EASX2FFiber2LinkLocal | read-only | current | Local device card fiber port 2 link status: 0:Down 1:Up |
| 1.3.6.1.4.1.4756.20.480.40.1.16 | Columnf1000EASX2FFiber2OAMLoopedLocal | read-only | current | Local device card fiber port 2 OAM looped: 0:Off 1:on |
| 1.3.6.1.4.1.4756.20.480.40.1.17 | Columnf1000EASX2FFiber2LBTestLocal | read-write | current | Force remote device card to do fiber port 2 LoopBack testing: 0:Off 1:Action |
| 1.3.6.1.4.1.4756.20.480.40.1.18 | Columnf1000EASX2FFiber2OAMRLBStatusLocal | read-only | current | Remote device card fiber port 1 LoopBack testing status: 0:Off 1:Ok 2:Fail |
| 1.3.6.1.4.1.4756.20.480.40.1.19 | Columnf1000EASX2FFiber2RemoPwrAbLocal | read-only | current | Local device card fiber port 2 Remote Power status: 0:Abnormal 1:OK 2:None |
| 1.3.6.1.4.1.4756.20.480.40.1.20 | Columnf1000EASX2FFiber2IngressRateLocal | read-write | current | Local device card fiber 2 Ingress Rate Limit: 0 = Unlimit input format: 64k(K),100m(M),100 If doesn't input the unit, the default was Mega. Limite Rate : 64K ~… |
| 1.3.6.1.4.1.4756.20.480.40.1.21 | Columnf1000EASX2FFiber2EgressRateLocal | read-write | current | Local device card fiber 2 Egress Rate Limit: 0 = Unlimit input format: 64k(K),100m(M),100 If doesn't input the unit, the default was Mega. Limite Rate : 64K ~ … |
| 1.3.6.1.4.1.4756.20.480.40.1.22 | Columnf1000EASX2FFiber1FEFLocal | read-only | current | Local device card fiber1 port FEF status: 0:Off 1:Detected |
| 1.3.6.1.4.1.4756.20.480.40.1.23 | Columnf1000EASX2FFiber2FEFLocal | read-only | current | Local device card fiber2 port FEF status: 0:Off 1:Detected |
| 1.3.6.1.4.1.4756.20.480.40.1.24 | Columnf1000EASX2FDeviceActiveLocal | read-write | current | Local device card active mode: (It is read-only in local device.) 0:Disable 1:Enable |
| 1.3.6.1.4.1.4756.20.480.40.1.25 | Columnf1000EASX2FDeviceResetLocal | read-write | current | Force local device card to reset mode: 0:Off 1:Action |
| 1.3.6.1.4.1.4756.20.480.40.1.26 | Columnf1000EASX2FFiber1ActiveLocal | read-write | current | Local device fiber port 1 active mode: 0:Disable 1:Enable |
| 1.3.6.1.4.1.4756.20.480.40.1.27 | Columnf1000EASX2FFiber2ActiveLocal | read-write | current | Local device fiber port 2 active mode: 0:Disable 1:Enable |
| 1.3.6.1.4.1.4756.20.480.40.1.28 | Columnf1000EASX2FOamChAModeLocal | read-write | current | Local device OAM Channel A mode: 0:Disable 1:passive 2:Active |
| 1.3.6.1.4.1.4756.20.480.40.1.29 | Columnf1000EASX2FOamChBModeLocal | read-write | current | Local device OAM Channel B mode: 0:Disable 1:passive 2:Active |
| 1.3.6.1.4.1.4756.20.480.40.1.30 | Columnf1000EASX2FOamMaxPDUsLocal | read-write | current | Local device OAM max OAMPDU size: 60-1518 Octets |
| 1.3.6.1.4.1.4756.20.480.40.1.31 | Columnf1000EASX2FFiber1AlsLocal | read-write | current | Local device card port 1 Auto Laser Shutdown mode: 0:Disable 1:Enable |
| 1.3.6.1.4.1.4756.20.480.40.1.32 | Columnf1000EASX2FFiber2AlsLocal | read-write | current | Local device card port 2 Auto Laser Shutdown mode: 0:Disable 1:Enable |
| 1.3.6.1.4.1.4756.20.480.40.1.33 | Columnf1000EASX2FPauseFrameLocal | read-write | current | Local device card pause frame mode: 0:Disable 1:Enable |
| 1.3.6.1.4.1.4756.20.480.40.1.34 | Columnf1000EASX2FSendFHRtoALocal | read-write | current | Local device card port 1 send Fiber Hardware Reset to remote: 0:No action 1:Action |
| 1.3.6.1.4.1.4756.20.480.40.1.35 | Columnf1000EASX2FSendFHRtoBLocal | read-write | current | Local device card port 2 send Fiber Hardware Reset to remote: 0:No action 1:Action |
| 1.3.6.1.4.1.4756.20.480.40.1.36 | Columnf1000EASX2FFiber1LLFDepPort2Local | read-write | current | Local device card port 1 Link Loss Forwarding depends on port 2 Fiber Rx link: 0:don't care 1:selected |
| 1.3.6.1.4.1.4756.20.480.40.1.37 | Columnf1000EASX2FFiber2LLFDepPort1Local | read-write | current | Local device card port 2 Link Loss Forwarding depends on port 1 Fiber Rx link: 0:don't care 1:selected |
| 1.3.6.1.4.1.4756.20.480.40.1.38 | Columnf1000EASX2FAdvanceFunsLocal | read-write | current | Local device card Switch functions mode: 0:Normal 5:Static 802.1Q VLAN 6:Spanning Tree Protocol 7:802.1Q VLAN Trunk 9:Q in Q VLAN 11:Spanning Tree Protocol and… |
| 1.3.6.1.4.1.4756.20.480.40.1.39 | Columnf1000EASX2FFiber1InfoROM1Local | read-only | current | Local device card port 1 INFORemoteOM information 1 valid: 0:Invalid 1:Valid |
| 1.3.6.1.4.1.4756.20.480.40.1.40 | Columnf1000EASX2FFiber1InfoROM2Local | read-only | current | Local device card port 1 INFORemoteOM information 2 valid: 0:Invalid 1:Valid(replacing D/D function |
| 1.3.6.1.4.1.4756.20.480.40.1.41 | Columnf1000EASX2FFiber2InfoROM1Local | read-only | current | Local device card port 2 INFORemoteOM information 1 valid: 0:Invalid 1:Valid |
| 1.3.6.1.4.1.4756.20.480.40.1.42 | Columnf1000EASX2FFiber2InfoROM2Local | read-only | current | Local device card port 2 INFORemoteOM information 2 valid: 0:Invalid 1:Valid(replacing D/D function) |
| 1.3.6.1.4.1.4756.20.480.40.1.43 | Columnf1000EASX2FFiber1InfoSN1Local | read-only | current | Local device card port 1 INFORemoteOM S/N 1 |
| 1.3.6.1.4.1.4756.20.480.40.1.44 | Columnf1000EASX2FFiber1InfoSN2Local | read-only | current | Local device card port 1 INFORemoteOM S/N 2 |
| 1.3.6.1.4.1.4756.20.480.40.1.45 | Columnf1000EASX2FFiber2InfoSN1Local | read-only | current | Local device card port 2 INFORemoteOM S/N 1 |
| 1.3.6.1.4.1.4756.20.480.40.1.46 | Columnf1000EASX2FFiber2InfoSN2Local | read-only | current | Local device card port 2 INFORemoteOM S/N 2 |
| 1.3.6.1.4.1.4756.20.480.40.1.47 | Columnf1000EASX2FFiber1DDLocal | read-only | current | Local device card fiber port 1 Digital Diagnostic function: 0:No 1:Yes |
| 1.3.6.1.4.1.4756.20.480.40.1.48 | Columnf1000EASX2FFiber1DDVendorLocal | read-only | current | Local device card fiber port 1 D/D information: Vendor name |
| 1.3.6.1.4.1.4756.20.480.40.1.49 | Columnf1000EASX2FFiber1DDPartNoLocal | read-only | current | Local device card fiber port 1 D/D information: Vendor part number |
| 1.3.6.1.4.1.4756.20.480.40.1.50 | Columnf1000EASX2FFiber1DDFiberTypeLocal | read-only | current | Local device card fiber port 1 D/D information: Fiber Type |
| 1.3.6.1.4.1.4756.20.480.40.1.51 | Columnf1000EASX2FFiber1DDWaveLenLocal | read-only | current | Local device card fiber port 1 D/D information: Wave length |
| 1.3.6.1.4.1.4756.20.480.40.1.52 | Columnf1000EASX2FFiber1DDWaveLen2Local | read-only | current | Local device card fiber port 1 D/D information: Wave length 2 |
| 1.3.6.1.4.1.4756.20.480.40.1.53 | Columnf1000EASX2FFiber1DDLinkLenLocal | read-only | current | Local device card fiber port 1 D/D information: Link length |
| 1.3.6.1.4.1.4756.20.480.40.1.54 | Columnf1000EASX2FFiber1DDLenUnitLocal | read-only | current | Local device card fiber port 1 D/D information: Length Unit |
| 1.3.6.1.4.1.4756.20.480.40.1.55 | Columnf1000EASX2FFiber1DDStatusLocal | read-only | current | Local device card fiber port 1 D/D information: Status Support |
| 1.3.6.1.4.1.4756.20.480.40.1.56 | Columnf1000EASX2FFiber1DDRxSensLocal | read-only | current | Local device card fiber port 1 D/D information: Rx Sensitivity |
| 1.3.6.1.4.1.4756.20.480.40.1.57 | Columnf1000EASX2FFiber1DDTxPWRLocal | read-only | current | Local device card fiber port 1 D/D information: Tx power |
| 1.3.6.1.4.1.4756.20.480.40.1.58 | Columnf1000EASX2FFiber1DDRxPWRLocal | read-only | current | Local device card fiber port 1 D/D information: Rx power |
| 1.3.6.1.4.1.4756.20.480.40.1.59 | Columnf1000EASX2FFiber1DDTempLocal | read-only | current | Local device card fiber port 1 D/D information: Temperature in degree C |
| 1.3.6.1.4.1.4756.20.480.40.1.60 | Columnf1000EASX2FFiber1DDPWRMarginLocal | read-only | current | Local device card fiber port 1 D/D information: Power margin |
| 1.3.6.1.4.1.4756.20.480.40.1.61 | Columnf1000EASX2FFiber1DDPWRLossLocal | read-only | current | Local device card fiber port 1 D/D information: Power loss |
| 1.3.6.1.4.1.4756.20.480.40.1.62 | Columnf1000EASX2FFiber2DDLocal | read-only | current | Local device card fiber port 2 Digital Diagnostic function: 0:No 1:Yes |
| 1.3.6.1.4.1.4756.20.480.40.1.63 | Columnf1000EASX2FFiber2DDVendorLocal | read-only | current | Local device card fiber port 2 D/D information: Vendor name |
| 1.3.6.1.4.1.4756.20.480.40.1.64 | Columnf1000EASX2FFiber2DDPartNoLocal | read-only | current | Local device card fiber port 2 D/D information: Vendor part number |
| 1.3.6.1.4.1.4756.20.480.40.1.65 | Columnf1000EASX2FFiber2DDFiberTypeLocal | read-only | current | Local device card fiber port 2 D/D information: Fiber Type |
| 1.3.6.1.4.1.4756.20.480.40.1.66 | Columnf1000EASX2FFiber2DDWaveLenLocal | read-only | current | Local device card fiber port 2 D/D information: Wave length |
| 1.3.6.1.4.1.4756.20.480.40.1.67 | Columnf1000EASX2FFiber2DDWaveLen2Local | read-only | current | Local device card fiber port 2 D/D information: Wave length 2 |
| 1.3.6.1.4.1.4756.20.480.40.1.68 | Columnf1000EASX2FFiber2DDLinkLenLocal | read-only | current | Local device card fiber port 2 D/D information: Link length |
| 1.3.6.1.4.1.4756.20.480.40.1.69 | Columnf1000EASX2FFiber2DDLenUnitLocal | read-only | current | Local device card fiber port 2 D/D information: Length Unit |
| 1.3.6.1.4.1.4756.20.480.40.1.70 | Columnf1000EASX2FFiber2DDStatusLocal | read-only | current | Local device card fiber port 2 D/D information: Status Support |
| 1.3.6.1.4.1.4756.20.480.40.1.71 | Columnf1000EASX2FFiber2DDRxSensLocal | read-only | current | Local device card fiber port 2 D/D information: Rx Sensitivity |
| 1.3.6.1.4.1.4756.20.480.40.1.72 | Columnf1000EASX2FFiber2DDTxPWRLocal | read-only | current | Local device card fiber port 2 D/D information: Tx power |
| 1.3.6.1.4.1.4756.20.480.40.1.73 | Columnf1000EASX2FFiber2DDRxPWRLocal | read-only | current | Local device card fiber port 2 D/D information: Rx power |
| 1.3.6.1.4.1.4756.20.480.40.1.74 | Columnf1000EASX2FFiber2DDTempLocal | read-only | current | Local device card fiber port 2 D/D information: Temperature in degree C |
| 1.3.6.1.4.1.4756.20.480.40.1.75 | Columnf1000EASX2FFiber2DDPWRMarginLocal | read-only | current | Local device card fiber port 2 D/D information: Power margin |
| 1.3.6.1.4.1.4756.20.480.40.1.76 | Columnf1000EASX2FFiber2DDPWRLossLocal | read-only | current | Local device card fiber port 2 D/D information: Power loss |
| 1.3.6.1.4.1.4756.20.480.40.1.77 | Columnf1000EASX2FClrRMONCntsLocal | read-write | current | Clear local device card RMON IN/OUT counters: 0:No action 1:Action |
| 1.3.6.1.4.1.4756.20.480.40.1.78 | Columnf1000EASX2FFiber1RMONInLocal | read-only | current | Local device card port 1 RMON IN counter. |
| 1.3.6.1.4.1.4756.20.480.40.1.79 | Columnf1000EASX2FFiber1RMONOutLocal | read-only | current | Local device card port 1 RMON OUT counter. |
| 1.3.6.1.4.1.4756.20.480.40.1.80 | Columnf1000EASX2FFiber2RMONInLocal | read-only | current | Local device card port 2 RMON IN counter. |
| 1.3.6.1.4.1.4756.20.480.40.1.81 | Columnf1000EASX2FFiber2RMONOutLocal | read-only | current | Local device card port 2 RMON OUT counter. |
| 1.3.6.1.4.1.4756.20.480.40.1.82 | Columnf1000EASX2FClrOAMCntsLocal | read-write | current | Clear local device card OAM counters: 0:No action 1:Action |
| 1.3.6.1.4.1.4756.20.480.40.1.83 | Columnf1000EASX2FIpModeLocal | read-write | current | On Rack Ip Mode: 0:Enable 1:Disable |
| 1.3.6.1.4.1.4756.20.480.40.1.84 | Columnf1000EASX2FOamChATxLocal | read-only | current | Local device OAM Channel A TX OAMPDU frame count |
| 1.3.6.1.4.1.4756.20.480.40.1.85 | Columnf1000EASX2FOamChARxLocal | read-only | current | Local device OAM Channel A RX OAMPDU frame count |
| 1.3.6.1.4.1.4756.20.480.40.1.86 | Columnf1000EASX2FOamInfoChATxLocal | read-only | current | Local device OAM Channel A TX Information OAMPDU frame count |
| 1.3.6.1.4.1.4756.20.480.40.1.87 | Columnf1000EASX2FOamInfoChARxLocal | read-only | current | Local device OAM Channel A RX Information OAMPDU frame count |
| 1.3.6.1.4.1.4756.20.480.40.1.88 | Columnf1000EASX2FOamEventChATxLocal | read-only | current | Local device OAM Channel A TX Event OAMPDU frame count |
| 1.3.6.1.4.1.4756.20.480.40.1.89 | Columnf1000EASX2FOamUniEvtChARxLocal | read-only | current | Local device OAM Channel A RX Unique Event OAMPDU frame count |
| 1.3.6.1.4.1.4756.20.480.40.1.90 | Columnf1000EASX2FOamDupEvtChARxLocal | read-only | current | Local device OAM Channel A RX Duplicate Event OAMPDU frame count |
| 1.3.6.1.4.1.4756.20.480.40.1.91 | Columnf1000EASX2FOamLbChATxLocal | read-only | current | Local device OAM Channel A TX Loopback Control OAMPDU frame count |
| 1.3.6.1.4.1.4756.20.480.40.1.92 | Columnf1000EASX2FOamLbChARxLocal | read-only | current | Local device OAM Channel A RX Loopback Control OAMPDU frame count |
| 1.3.6.1.4.1.4756.20.480.40.1.93 | Columnf1000EASX2FOamVarReqChATxLocal | read-only | current | Local device OAM Channel A TX Variable Request OAMPDU frame count |
| 1.3.6.1.4.1.4756.20.480.40.1.94 | Columnf1000EASX2FOamVarReqChARxLocal | read-only | current | Local device OAM Channel A RX Variable Request OAMPDU frame count |
| 1.3.6.1.4.1.4756.20.480.40.1.95 | Columnf1000EASX2FOamVarRspChATxLocal | read-only | current | Local device OAM Channel A TX Variable Response OAMPDU frame count |
| 1.3.6.1.4.1.4756.20.480.40.1.96 | Columnf1000EASX2FOamVarRspChARxLocal | read-only | current | Local device OAM Channel A RX Variable Response OAMPDU frame count |
| 1.3.6.1.4.1.4756.20.480.40.1.97 | Columnf1000EASX2FOamOuiChATxLocal | read-only | current | Local device OAM Channel A TX OUI OAMPDU frame count |
| 1.3.6.1.4.1.4756.20.480.40.1.98 | Columnf1000EASX2FOamOuiChARxLocal | read-only | current | Local device OAM Channel A RX OUI OAMPDU frame count |
| 1.3.6.1.4.1.4756.20.480.40.1.99 | Columnf1000EASX2FOamUnknowChARxLocal | read-only | current | Local device OAM Channel A RX Unsupported OAMPDU frame count |
| 1.3.6.1.4.1.4756.20.480.40.1.100 | Columnf1000EASX2FOamChBTxLocal | read-only | current | Local device OAM Channel B TX OAMPDU frame count |
| 1.3.6.1.4.1.4756.20.480.40.1.101 | Columnf1000EASX2FOamChBRxLocal | read-only | current | Local device OAM Channel B RX OAMPDU frame count |
| 1.3.6.1.4.1.4756.20.480.40.1.102 | Columnf1000EASX2FOamInfoChBTxLocal | read-only | current | Local device OAM Channel B TX Information OAMPDU frame count |
| 1.3.6.1.4.1.4756.20.480.40.1.103 | Columnf1000EASX2FOamInfoChBRxLocal | read-only | current | Local device OAM Channel B RX Information OAMPDU frame count |
| 1.3.6.1.4.1.4756.20.480.40.1.104 | Columnf1000EASX2FOamEventChBTxLocal | read-only | current | Local device OAM Channel B TX Event OAMPDU frame count |
| 1.3.6.1.4.1.4756.20.480.40.1.105 | Columnf1000EASX2FOamUniEvtChBRxLocal | read-only | current | Local device OAM Channel B RX Unique Event OAMPDU frame count |
| 1.3.6.1.4.1.4756.20.480.40.1.106 | Columnf1000EASX2FOamDupEvtChBRxLocal | read-only | current | Local device OAM Channel B RX Duplicate Event OAMPDU frame count |
| 1.3.6.1.4.1.4756.20.480.40.1.107 | Columnf1000EASX2FOamLbChBTxLocal | read-only | current | Local device OAM Channel B TX Loopback Control OAMPDU frame count |
| 1.3.6.1.4.1.4756.20.480.40.1.108 | Columnf1000EASX2FOamLbChBRxLocal | read-only | current | Local device OAM Channel B RX Loopback Control OAMPDU frame count |
| 1.3.6.1.4.1.4756.20.480.40.1.109 | Columnf1000EASX2FOamVarReqChBTxLocal | read-only | current | Local device OAM Channel B TX Variable Request OAMPDU frame count |
| 1.3.6.1.4.1.4756.20.480.40.1.110 | Columnf1000EASX2FOamVarReqChBRxLocal | read-only | current | Local device OAM Channel B RX Variable Request OAMPDU frame count |
| 1.3.6.1.4.1.4756.20.480.40.1.111 | Columnf1000EASX2FOamVarRspChBTxLocal | read-only | current | Local device OAM Channel B TX Variable Response OAMPDU frame count |
| 1.3.6.1.4.1.4756.20.480.40.1.112 | Columnf1000EASX2FOamVarRspChBRxLocal | read-only | current | Local device OAM Channel B RX Variable Response OAMPDU frame count |
| 1.3.6.1.4.1.4756.20.480.40.1.113 | Columnf1000EASX2FOamOuiChBTxLocal | read-only | current | Local device OAM Channel B TX OUI OAMPDU frame count |
| 1.3.6.1.4.1.4756.20.480.40.1.114 | Columnf1000EASX2FOamOuiChBRxLocal | read-only | current | Local device OAM Channel B RX OUI OAMPDU frame count |
| 1.3.6.1.4.1.4756.20.480.40.1.115 | Columnf1000EASX2FOamUnknowChBRxLocal | read-only | current | Local device OAM Channel B RX Unsupported OAMPDU frame count |
| 1.3.6.1.4.1.4756.20.480.40.1.116 | Columnf1000EASX2FFiber1SpeedLocal | read-write | current | Local device Fiber 1 speed : 0:1000Auto 1:1000FDX 2:100FDX |
| 1.3.6.1.4.1.4756.20.480.40.1.117 | Columnf1000EASX2FFiber2SpeedLocal | read-write | current | Local device Fiber 2 speed : 0:1000Auto 1:1000FDX 2:100FDX |
| 1.3.6.1.4.1.4756.20.480.40.1.118 | Columnf1000EASX2FMacLearningLocal | read-write | current | Local device Mac learning : 0:Disable 1:Enable |
| 1.3.6.1.4.1.4756.20.480.40.1.119 | Columnf1000EASX2FManagementVIDLocal | read-write | current | Local device Management VID : |
| 1.3.6.1.4.1.4756.20.480.40.1.120 | Columnf1000EASX2FTagTypeLocal | read-write | current | Local device Tag Type (HEX) : |
| 1.3.6.1.4.1.4756.20.480.40.1.121 | Columnf1000EASX2FPort1VIDLocal | read-write | current | Local device Port 1 VID : |
| 1.3.6.1.4.1.4756.20.480.40.1.122 | Columnf1000EASX2FPort2VIDLocal | read-write | current | Local device Port 2 VID : |
| 1.3.6.1.4.1.4756.20.480.40.1.123 | Columnf1000EASX2FPort1QinQLocal | read-write | current | Local device Port 1 Q in Q Support : 1:Disable 2:Enable |
| 1.3.6.1.4.1.4756.20.480.40.1.124 | Columnf1000EASX2FPort2QinQLocal | read-write | current | Local device Port 2 Q in Q Support : 1:Disable 2:Enable |
| 1.3.6.1.4.1.4756.20.480.40.1.125 | Columnf1000EASX2FVID1Local | read-write | current | Local device VID 1: |
| 1.3.6.1.4.1.4756.20.480.40.1.126 | Columnf1000EASX2FVID2Local | read-write | current | Local device VID 2: |
| 1.3.6.1.4.1.4756.20.480.40.1.127 | Columnf1000EASX2FVID3Local | read-write | current | Local device VID 3: |
| 1.3.6.1.4.1.4756.20.480.40.1.128 | Columnf1000EASX2FVID4Local | read-write | current | Local device VID 4: |
| 1.3.6.1.4.1.4756.20.480.40.1.129 | Columnf1000EASX2FVID5Local | read-write | current | Local device VID 5: |
| 1.3.6.1.4.1.4756.20.480.40.1.130 | Columnf1000EASX2FVID6Local | read-write | current | Local device VID 6: |
| 1.3.6.1.4.1.4756.20.480.40.1.131 | Columnf1000EASX2FVID7Local | read-write | current | Local device VID 7: |
| 1.3.6.1.4.1.4756.20.480.40.1.132 | Columnf1000EASX2FVID8Local | read-write | current | Local device VID 8: |
| 1.3.6.1.4.1.4756.20.480.40.1.133 | Columnf1000EASX2FVID9Local | read-write | current | Local device VID 9: |
| 1.3.6.1.4.1.4756.20.480.40.1.134 | Columnf1000EASX2FVID10Local | read-write | current | Local device VID 10: |
| 1.3.6.1.4.1.4756.20.480.40.1.135 | Columnf1000EASX2FVID11Local | read-write | current | Local device VID 11: |
| 1.3.6.1.4.1.4756.20.480.40.1.136 | Columnf1000EASX2FVID12Local | read-write | current | Local device VID 12: |
| 1.3.6.1.4.1.4756.20.480.40.1.137 | Columnf1000EASX2FVID13Local | read-write | current | Local device VID 13: |
| 1.3.6.1.4.1.4756.20.480.40.1.138 | Columnf1000EASX2FVID14Local | read-write | current | Local device VID 14: |
| 1.3.6.1.4.1.4756.20.480.40.1.139 | Columnf1000EASX2FVID15Local | read-write | current | Local device VID 15: |
| 1.3.6.1.4.1.4756.20.480.40.1.140 | Columnf1000EASX2FVID16Local | read-write | current | Local device VID 16: |
| 1.3.6.1.4.1.4756.20.480.40.1.141 | Columnf1000EASX2FPort1Member1Local | read-write | current | Local device card port 1 member: 0:Unmodify 1:Untagged 2:Tagged 3:Nonmember |
| 1.3.6.1.4.1.4756.20.480.40.1.142 | Columnf1000EASX2FPort1Member2Local | read-write | current | Local device card port 1 member 2: 0:Unmodify 1:Untagged 2:Tagged 3:Nonmember |
| 1.3.6.1.4.1.4756.20.480.40.1.143 | Columnf1000EASX2FPort1Member3Local | read-write | current | Local device card port 1 member 3: 0:Unmodify 1:Untagged 2:Tagged 3:Nonmember |
| 1.3.6.1.4.1.4756.20.480.40.1.144 | Columnf1000EASX2FPort1Member4Local | read-write | current | Local device card port 1 member 4: 0:Unmodify 1:Untagged 2:Tagged 3:Nonmember |
| 1.3.6.1.4.1.4756.20.480.40.1.145 | Columnf1000EASX2FPort1Member5Local | read-write | current | Local device card port 1 member 5: 0:Unmodify 1:Untagged 2:Tagged 3:Nonmember |
| 1.3.6.1.4.1.4756.20.480.40.1.146 | Columnf1000EASX2FPort1Member6Local | read-write | current | Local device card port 1 member 6: 0:Unmodify 1:Untagged 2:Tagged 3:Nonmember |
| 1.3.6.1.4.1.4756.20.480.40.1.147 | Columnf1000EASX2FPort1Member7Local | read-write | current | Local device card port 1 member 7: 0:Unmodify 1:Untagged 2:Tagged 3:Nonmember |
| 1.3.6.1.4.1.4756.20.480.40.1.148 | Columnf1000EASX2FPort1Member8Local | read-write | current | Local device card port 1 member 8: 0:Unmodify 1:Untagged 2:Tagged 3:Nonmember |
| 1.3.6.1.4.1.4756.20.480.40.1.149 | Columnf1000EASX2FPort1Member9Local | read-write | current | Local device card port 1 member 9: 0:Unmodify 1:Untagged 2:Tagged 3:Nonmember |
| 1.3.6.1.4.1.4756.20.480.40.1.150 | Columnf1000EASX2FPort1Member10Local | read-write | current | Local device card port 1 member 10: 0:Unmodify 1:Untagged 2:Tagged 3:Nonmember |
| 1.3.6.1.4.1.4756.20.480.40.1.151 | Columnf1000EASX2FPort1Member11Local | read-write | current | Local device card port 1 member 11: 0:Unmodify 1:Untagged 2:Tagged 3:Nonmember |
| 1.3.6.1.4.1.4756.20.480.40.1.152 | Columnf1000EASX2FPort1Member12Local | read-write | current | Local device card port 1 member 12: 0:Unmodify 1:Untagged 2:Tagged 3:Nonmember |
| 1.3.6.1.4.1.4756.20.480.40.1.153 | Columnf1000EASX2FPort1Member13Local | read-write | current | Local device card port 1 member 13: 0:Unmodify 1:Untagged 2:Tagged 3:Nonmember |
| 1.3.6.1.4.1.4756.20.480.40.1.154 | Columnf1000EASX2FPort1Member14Local | read-write | current | Local device card port 1 member 14: 0:Unmodify 1:Untagged 2:Tagged 3:Nonmember |
| 1.3.6.1.4.1.4756.20.480.40.1.155 | Columnf1000EASX2FPort1Member15Local | read-write | current | Local device card port 1 member 15: 0:Unmodify 1:Untagged 2:Tagged 3:Nonmember |
| 1.3.6.1.4.1.4756.20.480.40.1.156 | Columnf1000EASX2FPort1Member16Local | read-write | current | Local device card port 1 member 16: 0:Unmodify 1:Untagged 2:Tagged 3:Nonmember |
| 1.3.6.1.4.1.4756.20.480.40.1.157 | Columnf1000EASX2FPort2Member1Local | read-write | current | Local device card port 2 member: 0:Unmodify 1:Untagged 2:Tagged 3:Nonmember |
| 1.3.6.1.4.1.4756.20.480.40.1.158 | Columnf1000EASX2FPort2Member2Local | read-write | current | Local device card port 2 member 2: 0:Unmodify 1:Untagged 2:Tagged 3:Nonmember |
| 1.3.6.1.4.1.4756.20.480.40.1.159 | Columnf1000EASX2FPort2Member3Local | read-write | current | Local device card port 2 member 3: 0:Unmodify 1:Untagged 2:Tagged 3:Nonmember |
| 1.3.6.1.4.1.4756.20.480.40.1.160 | Columnf1000EASX2FPort2Member4Local | read-write | current | Local device card port 2 member 4: 0:Unmodify 1:Untagged 2:Tagged 3:Nonmember |
| 1.3.6.1.4.1.4756.20.480.40.1.161 | Columnf1000EASX2FPort2Member5Local | read-write | current | Local device card port 2 member 5: 0:Unmodify 1:Untagged 2:Tagged 3:Nonmember |
| 1.3.6.1.4.1.4756.20.480.40.1.162 | Columnf1000EASX2FPort2Member6Local | read-write | current | Local device card port 2 member 6: 0:Unmodify 1:Untagged 2:Tagged 3:Nonmember |
| 1.3.6.1.4.1.4756.20.480.40.1.163 | Columnf1000EASX2FPort2Member7Local | read-write | current | Local device card port 2 member 7: 0:Unmodify 1:Untagged 2:Tagged 3:Nonmember |
| 1.3.6.1.4.1.4756.20.480.40.1.164 | Columnf1000EASX2FPort2Member8Local | read-write | current | Local device card port 2 member 8: 0:Unmodify 1:Untagged 2:Tagged 3:Nonmember |
| 1.3.6.1.4.1.4756.20.480.40.1.165 | Columnf1000EASX2FPort2Member9Local | read-write | current | Local device card port 2 member 9: 0:Unmodify 1:Untagged 2:Tagged 3:Nonmember |
| 1.3.6.1.4.1.4756.20.480.40.1.166 | Columnf1000EASX2FPort2Member10Local | read-write | current | Local device card port 2 member 10: 0:Unmodify 1:Untagged 2:Tagged 3:Nonmember |
| 1.3.6.1.4.1.4756.20.480.40.1.167 | Columnf1000EASX2FPort2Member11Local | read-write | current | Local device card port 2 member 11: 0:Unmodify 1:Untagged 2:Tagged 3:Nonmember |
| 1.3.6.1.4.1.4756.20.480.40.1.168 | Columnf1000EASX2FPort2Member12Local | read-write | current | Local device card port 2 member 12: 0:Unmodify 1:Untagged 2:Tagged 3:Nonmember |
| 1.3.6.1.4.1.4756.20.480.40.1.169 | Columnf1000EASX2FPort2Member13Local | read-write | current | Local device card port 2 member 13: 0:Unmodify 1:Untagged 2:Tagged 3:Nonmember |
| 1.3.6.1.4.1.4756.20.480.40.1.170 | Columnf1000EASX2FPort2Member14Local | read-write | current | Local device card port 2 member 14: 0:Unmodify 1:Untagged 2:Tagged 3:Nonmember |
| 1.3.6.1.4.1.4756.20.480.40.1.171 | Columnf1000EASX2FPort2Member15Local | read-write | current | Local device card port 2 member 15: 0:Unmodify 1:Untagged 2:Tagged 3:Nonmember |
| 1.3.6.1.4.1.4756.20.480.40.1.172 | Columnf1000EASX2FPort2Member16Local | read-write | current | Local device card port 2 member 16: 0:Unmodify 1:Untagged 2:Tagged 3:Nonmember |
| 1.3.6.1.4.1.4756.20.480.40.1.173 | Columnf1000EASX2FIpAddressLocal | read-write | current | Local device IP address |
| 1.3.6.1.4.1.4756.20.480.40.1.174 | Columnf1000EASX2FNetMaskLocal | read-write | current | Local device Netmask |
| 1.3.6.1.4.1.4756.20.480.40.1.175 | Columnf1000EASX2FGateWayLocal | read-write | current | Local device Gateway |
| 1.3.6.1.4.1.4756.20.480.40.1.176 | Columnf1000EASX2FSetDefaultLocal | read-write | current | Local device set to default |
| 1.3.6.1.4.1.4756.20.480.40.1.177 | Columnf1000EASX2FFx1LinkAlarmLocal | read-write | current | Local device fiber 1 link alarm 0:Disable 1:Enable |
| 1.3.6.1.4.1.4756.20.480.40.1.178 | Columnf1000EASX2FFx2LinkAlarmLocal | read-write | current | Local device fiber 2 link alarm 0:Disable 1:Enable |
| 1.3.6.1.4.1.4756.20.480.40.1.179 | Columnf1000EASX2FPingStatusLocal | read-only | current | Local device icmp ping status Show Ping Status 0: Normal 1: Not Ready 2: 5 packets transmitted, 5 received, 0 packet loss. (Ping OK) 3: 5 packets transmitted, … |
| 1.3.6.1.4.1.4756.20.480.40.1.180 | Columnf1000EASX2FPingIpAddressLocal | read-write | current | Local device ping IP address |
| 1.3.6.1.4.1.4756.20.480.40.1.181 | Columnf1000EASX2FPingStartLocal | read-write | current | Local device ping start 0:Off 1:Action |
| 1.3.6.1.4.1.4756.20.480.40.1.182 | Columnf1000EASX2FRemoteTLPTLocal | read-write | current | Local device Remote TLPT mode : 0:Disalbe 1:Remote A 2:Remote B |
| 1.3.6.1.4.1.4756.20.480.40.1.183 | Columnf1000EASX2FFx1LBTLocal | read-write | current | FRM220-1000EAS/X-2F Fiber 1 LoopBack Test: 0: Disalbe 1: Enable 2: Not Support |
| 1.3.6.1.4.1.4756.20.480.40.1.184 | Columnf1000EASX2FFx2LBTLocal | read-write | current | FRM220-1000EAS/X-2F Fiber 2 LoopBack Test: 0: Disalbe 1: Enable 2: Not Support |
| 1.3.6.1.4.1.4756.20.481 | Nodef1000EASX2FRemoteACards | |||
| 1.3.6.1.4.1.4756.20.481.40 | Tablef1000EASX2FRemoteATable | not-accessible | current | A list of RemoteA 1000EAS/X-2F card entries. |
| 1.3.6.1.4.1.4756.20.481.40.1 | Rowf1000EASX2FRemoteAEntry | not-accessible | current | An entry containing management information applicable to a particular RemoteA 1000EAS/X-2F card. |
| 1.3.6.1.4.1.4756.20.481.40.1.1 | Columnf1000EASX2FChassisIndexRemoteA | read-only | current | A unique value for each chassis ID. For CH20, it is the chassis ID. For CH08, it is always 0. |
| 1.3.6.1.4.1.4756.20.481.40.1.2 | Columnf1000EASX2FSlotIndexRemoteA | read-only | current | A unique value for each local card. It is the slot location number. |
| 1.3.6.1.4.1.4756.20.481.40.1.3 | Columnf1000EASX2FCardHWVerRemoteA | read-only | current | RemoteA device card hardware version x.xxx |
| 1.3.6.1.4.1.4756.20.481.40.1.4 | Columnf1000EASX2FCardFWVerRemoteA | read-only | current | RemoteA device card firmware version x.xxx |
| 1.3.6.1.4.1.4756.20.481.40.1.5 | Columnf1000EASX2FCardCPLDVerRemoteA | read-only | current | RemoteA device card CPLD version x.xxx |
| 1.3.6.1.4.1.4756.20.481.40.1.6 | Columnf1000EASX2FCardFPGAVerRemoteA | read-only | current | RemoteA device card FPGA version x.xxx |
| 1.3.6.1.4.1.4756.20.481.40.1.7 | Columnf1000EASX2FModelRemoteA | read-only | current | RemoteA 1000EAS/X Serial Type |
| 1.3.6.1.4.1.4756.20.481.40.1.8 | Columnf1000EASX2FFiber1LinkRemoteA | read-only | current | RemoteA device card fiber port 1 link status: 0:Down 1:Up |
| 1.3.6.1.4.1.4756.20.481.40.1.9 | Columnf1000EASX2FFiber1OAMLoopedRemoteA | read-only | current | RemoteA device card fiber port 1 OAM looped: 0:Off 1:on |
| 1.3.6.1.4.1.4756.20.481.40.1.10 | Columnf1000EASX2FFiber1LBTestRemoteA | read-write | current | Force remote device card to do fiber port 1 LoopBack testing: 0:Off 1:Action |
| 1.3.6.1.4.1.4756.20.481.40.1.11 | Columnf1000EASX2FFiber1OAMRLBStatusRemoteA | read-only | current | Remote device card fiber port 1 LoopBack testing status: 0:Off 1:Ok 2:Fail |
| 1.3.6.1.4.1.4756.20.481.40.1.12 | Columnf1000EASX2FFiber1RemoPwrAbRemoteA | read-only | current | RemoteA device card fiber port 1 Remote Power status: 0:Abnormal 1:OK 2:None |
| 1.3.6.1.4.1.4756.20.481.40.1.13 | Columnf1000EASX2FFiber1IngressRateRemoteA | read-write | current | RemoteA device card fiber 1 Ingress Rate Limit: 0 = Unlimit input format: 64k(K),100m(M),100 If doesn't input the unit, the default was Mega. Limite Rate : 64K… |
| 1.3.6.1.4.1.4756.20.481.40.1.14 | Columnf1000EASX2FFiber1EgressRateRemoteA | read-write | current | RemoteA device card fiber 1 Egress Rate Limit: 0 = Unlimit input format: 64k(K),100m(M),100 If doesn't input the unit, the default was Mega. Limite Rate : 64K … |
| 1.3.6.1.4.1.4756.20.481.40.1.15 | Columnf1000EASX2FFiber2LinkRemoteA | read-only | current | RemoteA device card fiber port 2 link status: 0:Down 1:Up |
| 1.3.6.1.4.1.4756.20.481.40.1.16 | Columnf1000EASX2FFiber2OAMLoopedRemoteA | read-only | current | RemoteA device card fiber port 2 OAM looped: 0:Off 1:on |
| 1.3.6.1.4.1.4756.20.481.40.1.17 | Columnf1000EASX2FFiber2LBTestRemoteA | read-write | current | Force remote device card to do fiber port 2 LoopBack testing: 0:Off 1:Action |
| 1.3.6.1.4.1.4756.20.481.40.1.18 | Columnf1000EASX2FFiber2OAMRLBStatusRemoteA | read-only | current | Remote device card fiber port 1 LoopBack testing status: 0:Off 1:Ok 2:Fail |
| 1.3.6.1.4.1.4756.20.481.40.1.19 | Columnf1000EASX2FFiber2RemoPwrAbRemoteA | read-only | current | RemoteA device card fiber port 2 Remote Power status: 0:Abnormal 1:OK 2:None |
| 1.3.6.1.4.1.4756.20.481.40.1.20 | Columnf1000EASX2FFiber2IngressRateRemoteA | read-write | current | RemoteA device card fiber 2 Ingress Rate Limit: 0 = Unlimit input format: 64k(K),100m(M),100 If doesn't input the unit, the default was Mega. Limite Rate : 64K… |
| 1.3.6.1.4.1.4756.20.481.40.1.21 | Columnf1000EASX2FFiber2EgressRateRemoteA | read-write | current | RemoteA device card fiber 2 Egress Rate Limit: 0 = Unlimit input format: 64k(K),100m(M),100 If doesn't input the unit, the default was Mega. Limite Rate : 64K … |
| 1.3.6.1.4.1.4756.20.481.40.1.22 | Columnf1000EASX2FFiber1FEFRemoteA | read-only | current | RemoteA device card fiber1 port FEF status: 0:Off 1:Detected |
| 1.3.6.1.4.1.4756.20.481.40.1.23 | Columnf1000EASX2FFiber2FEFRemoteA | read-only | current | RemoteA device card fiber2 port FEF status: 0:Off 1:Detected |
| 1.3.6.1.4.1.4756.20.481.40.1.24 | Columnf1000EASX2FDeviceActiveRemoteA | read-only | current | RemoteA device card active mode: (It is read-only in local device.) 0:Disable 1:Enable |
| 1.3.6.1.4.1.4756.20.481.40.1.25 | Columnf1000EASX2FDeviceResetRemoteA | read-write | current | Force local device card to reset mode: 0:Off 1:Action |
| 1.3.6.1.4.1.4756.20.481.40.1.26 | Columnf1000EASX2FFiber1ActiveRemoteA | read-write | current | RemoteA device fiber port 1 active mode: 0:Disable 1:Enable |
| 1.3.6.1.4.1.4756.20.481.40.1.27 | Columnf1000EASX2FFiber2ActiveRemoteA | read-write | current | RemoteA device fiber port 2 active mode: 0:Disable 1:Enable |
| 1.3.6.1.4.1.4756.20.481.40.1.28 | Columnf1000EASX2FOamChAModeRemoteA | read-write | current | RemoteA device OAM Channel A mode: 0:Disable 1:passive 2:Active |
| 1.3.6.1.4.1.4756.20.481.40.1.29 | Columnf1000EASX2FOamChBModeRemoteA | read-write | current | RemoteA device OAM Channel B mode: 0:Disable 1:passive 2:Active |
| 1.3.6.1.4.1.4756.20.481.40.1.30 | Columnf1000EASX2FOamMaxPDUsRemoteA | read-write | current | RemoteA device OAM max OAMPDU size: 60-1518 Octets |
| 1.3.6.1.4.1.4756.20.481.40.1.31 | Columnf1000EASX2FFiber1AlsRemoteA | read-write | current | RemoteA device card port 1 Auto Laser Shutdown mode: 0:Disable 1:Enable |
| 1.3.6.1.4.1.4756.20.481.40.1.32 | Columnf1000EASX2FFiber2AlsRemoteA | read-write | current | RemoteA device card port 2 Auto Laser Shutdown mode: 0:Disable 1:Enable |
| 1.3.6.1.4.1.4756.20.481.40.1.33 | Columnf1000EASX2FPauseFrameRemoteA | read-write | current | RemoteA device card pause frame mode: 0:Disable 1:Enable |
| 1.3.6.1.4.1.4756.20.481.40.1.34 | Columnf1000EASX2FSendFHRtoARemoteA | read-write | current | RemoteA device card port 1 send Fiber Hardware Reset to remote: 0:No action 1:Action |
| 1.3.6.1.4.1.4756.20.481.40.1.35 | Columnf1000EASX2FSendFHRtoBRemoteA | read-write | current | RemoteA device card port 2 send Fiber Hardware Reset to remote: 0:No action 1:Action |
| 1.3.6.1.4.1.4756.20.481.40.1.36 | Columnf1000EASX2FFiber1LLFDepPort2RemoteA | read-write | current | RemoteA device card port 1 Link Loss Forwarding depends on port 2 Fiber Rx link: 0:don't care 1:selected |
| 1.3.6.1.4.1.4756.20.481.40.1.37 | Columnf1000EASX2FFiber2LLFDepPort1RemoteA | read-write | current | RemoteA device card port 2 Link Loss Forwarding depends on port 1 Fiber Rx link: 0:don't care 1:selected |
| 1.3.6.1.4.1.4756.20.481.40.1.38 | Columnf1000EASX2FAdvanceFunsRemoteA | read-write | current | RemoteA device card Switch functions mode: 0:Normal 5:Static 802.1Q VLAN 6:Spanning Tree Protocol 7:802.1Q VLAN Trunk 9:Q in Q VLAN 11:Spanning Tree Protocol a… |
| 1.3.6.1.4.1.4756.20.481.40.1.39 | Columnf1000EASX2FFiber1InfoROM1RemoteA | read-only | current | RemoteA device card port 1 INFORemoteOM information 1 valid: 0:Invalid 1:Valid |
| 1.3.6.1.4.1.4756.20.481.40.1.40 | Columnf1000EASX2FFiber1InfoROM2RemoteA | read-only | current | RemoteA device card port 1 INFORemoteOM information 2 valid: 0:Invalid 1:Valid(replacing D/D function |
| 1.3.6.1.4.1.4756.20.481.40.1.41 | Columnf1000EASX2FFiber2InfoROM1RemoteA | read-only | current | RemoteA device card port 2 INFORemoteOM information 1 valid: 0:Invalid 1:Valid |
| 1.3.6.1.4.1.4756.20.481.40.1.42 | Columnf1000EASX2FFiber2InfoROM2RemoteA | read-only | current | RemoteA device card port 2 INFORemoteOM information 2 valid: 0:Invalid 1:Valid(replacing D/D function) |
| 1.3.6.1.4.1.4756.20.481.40.1.43 | Columnf1000EASX2FFiber1InfoSN1RemoteA | read-only | current | RemoteA device card port 1 INFORemoteOM S/N 1 |
| 1.3.6.1.4.1.4756.20.481.40.1.44 | Columnf1000EASX2FFiber1InfoSN2RemoteA | read-only | current | RemoteA device card port 1 INFORemoteOM S/N 2 |
| 1.3.6.1.4.1.4756.20.481.40.1.45 | Columnf1000EASX2FFiber2InfoSN1RemoteA | read-only | current | RemoteA device card port 2 INFORemoteOM S/N 1 |
| 1.3.6.1.4.1.4756.20.481.40.1.46 | Columnf1000EASX2FFiber2InfoSN2RemoteA | read-only | current | RemoteA device card port 2 INFORemoteOM S/N 2 |
| 1.3.6.1.4.1.4756.20.481.40.1.47 | Columnf1000EASX2FFiber1DDRemoteA | read-only | current | RemoteA device card fiber port 1 Digital Diagnostic function: 0:No 1:Yes |
| 1.3.6.1.4.1.4756.20.481.40.1.48 | Columnf1000EASX2FFiber1DDVendorRemoteA | read-only | current | RemoteA device card fiber port 1 D/D information: Vendor name |
| 1.3.6.1.4.1.4756.20.481.40.1.49 | Columnf1000EASX2FFiber1DDPartNoRemoteA | read-only | current | RemoteA device card fiber port 1 D/D information: Vendor part number |
| 1.3.6.1.4.1.4756.20.481.40.1.50 | Columnf1000EASX2FFiber1DDFiberTypeRemoteA | read-only | current | RemoteA device card fiber port 1 D/D information: Fiber Type |
| 1.3.6.1.4.1.4756.20.481.40.1.51 | Columnf1000EASX2FFiber1DDWaveLenRemoteA | read-only | current | RemoteA device card fiber port 1 D/D information: Wave length |
| 1.3.6.1.4.1.4756.20.481.40.1.52 | Columnf1000EASX2FFiber1DDWaveLen2RemoteA | read-only | current | RemoteA device card fiber port 1 D/D information: Wave length 2 |
| 1.3.6.1.4.1.4756.20.481.40.1.53 | Columnf1000EASX2FFiber1DDLinkLenRemoteA | read-only | current | RemoteA device card fiber port 1 D/D information: Link length |
| 1.3.6.1.4.1.4756.20.481.40.1.54 | Columnf1000EASX2FFiber1DDLenUnitRemoteA | read-only | current | RemoteA device card fiber port 1 D/D information: Length Unit |
| 1.3.6.1.4.1.4756.20.481.40.1.55 | Columnf1000EASX2FFiber1DDStatusRemoteA | read-only | current | RemoteA device card fiber port 1 D/D information: Status Support |
| 1.3.6.1.4.1.4756.20.481.40.1.56 | Columnf1000EASX2FFiber1DDRxSensRemoteA | read-only | current | RemoteA device card fiber port 1 D/D information: Rx Sensitivity |
| 1.3.6.1.4.1.4756.20.481.40.1.57 | Columnf1000EASX2FFiber1DDTxPWRRemoteA | read-only | current | RemoteA device card fiber port 1 D/D information: Tx power |
| 1.3.6.1.4.1.4756.20.481.40.1.58 | Columnf1000EASX2FFiber1DDRxPWRRemoteA | read-only | current | RemoteA device card fiber port 1 D/D information: Rx power |
| 1.3.6.1.4.1.4756.20.481.40.1.59 | Columnf1000EASX2FFiber1DDTempRemoteA | read-only | current | RemoteA device card fiber port 1 D/D information: Temperature in degree C |
| 1.3.6.1.4.1.4756.20.481.40.1.60 | Columnf1000EASX2FFiber1DDPWRMarginRemoteA | read-only | current | RemoteA device card fiber port 1 D/D information: Power margin |
| 1.3.6.1.4.1.4756.20.481.40.1.61 | Columnf1000EASX2FFiber1DDPWRLossRemoteA | read-only | current | RemoteA device card fiber port 1 D/D information: Power loss |
| 1.3.6.1.4.1.4756.20.481.40.1.62 | Columnf1000EASX2FFiber2DDRemoteA | read-only | current | RemoteA device card fiber port 2 Digital Diagnostic function: 0:No 1:Yes |
| 1.3.6.1.4.1.4756.20.481.40.1.63 | Columnf1000EASX2FFiber2DDVendorRemoteA | read-only | current | RemoteA device card fiber port 2 D/D information: Vendor name |
| 1.3.6.1.4.1.4756.20.481.40.1.64 | Columnf1000EASX2FFiber2DDPartNoRemoteA | read-only | current | RemoteA device card fiber port 2 D/D information: Vendor part number |
| 1.3.6.1.4.1.4756.20.481.40.1.65 | Columnf1000EASX2FFiber2DDFiberTypeRemoteA | read-only | current | RemoteA device card fiber port 2 D/D information: Fiber Type |
| 1.3.6.1.4.1.4756.20.481.40.1.66 | Columnf1000EASX2FFiber2DDWaveLenRemoteA | read-only | current | RemoteA device card fiber port 2 D/D information: Wave length |
| 1.3.6.1.4.1.4756.20.481.40.1.67 | Columnf1000EASX2FFiber2DDWaveLen2RemoteA | read-only | current | RemoteA device card fiber port 2 D/D information: Wave length 2 |
| 1.3.6.1.4.1.4756.20.481.40.1.68 | Columnf1000EASX2FFiber2DDLinkLenRemoteA | read-only | current | RemoteA device card fiber port 2 D/D information: Link length |
| 1.3.6.1.4.1.4756.20.481.40.1.69 | Columnf1000EASX2FFiber2DDLenUnitRemoteA | read-only | current | RemoteA device card fiber port 2 D/D information: Length Unit |
| 1.3.6.1.4.1.4756.20.481.40.1.70 | Columnf1000EASX2FFiber2DDStatusRemoteA | read-only | current | RemoteA device card fiber port 2 D/D information: Status Support |
| 1.3.6.1.4.1.4756.20.481.40.1.71 | Columnf1000EASX2FFiber2DDRxSensRemoteA | read-only | current | RemoteA device card fiber port 2 D/D information: Rx Sensitivity |
| 1.3.6.1.4.1.4756.20.481.40.1.72 | Columnf1000EASX2FFiber2DDTxPWRRemoteA | read-only | current | RemoteA device card fiber port 2 D/D information: Tx power |
| 1.3.6.1.4.1.4756.20.481.40.1.73 | Columnf1000EASX2FFiber2DDRxPWRRemoteA | read-only | current | RemoteA device card fiber port 2 D/D information: Rx power |
| 1.3.6.1.4.1.4756.20.481.40.1.74 | Columnf1000EASX2FFiber2DDTempRemoteA | read-only | current | RemoteA device card fiber port 2 D/D information: Temperature in degree C |
| 1.3.6.1.4.1.4756.20.481.40.1.75 | Columnf1000EASX2FFiber2DDPWRMarginRemoteA | read-only | current | RemoteA device card fiber port 2 D/D information: Power margin |
| 1.3.6.1.4.1.4756.20.481.40.1.76 | Columnf1000EASX2FFiber2DDPWRLossRemoteA | read-only | current | RemoteA device card fiber port 2 D/D information: Power loss |
| 1.3.6.1.4.1.4756.20.481.40.1.77 | Columnf1000EASX2FClrRMONCntsRemoteA | read-write | current | Clear local device card RMON IN/OUT counters: 0:No action 1:Action |
| 1.3.6.1.4.1.4756.20.481.40.1.78 | Columnf1000EASX2FFiber1RMONInRemoteA | read-only | current | RemoteA device card port 1 RMON IN counter. |
| 1.3.6.1.4.1.4756.20.481.40.1.79 | Columnf1000EASX2FFiber1RMONOutRemoteA | read-only | current | RemoteA device card port 1 RMON OUT counter. |
| 1.3.6.1.4.1.4756.20.481.40.1.80 | Columnf1000EASX2FFiber2RMONInRemoteA | read-only | current | RemoteA device card port 2 RMON IN counter. |
| 1.3.6.1.4.1.4756.20.481.40.1.81 | Columnf1000EASX2FFiber2RMONOutRemoteA | read-only | current | RemoteA device card port 2 RMON OUT counter. |
| 1.3.6.1.4.1.4756.20.481.40.1.82 | Columnf1000EASX2FClrOAMCntsRemoteA | read-write | current | Clear local device card OAM counters: 0:No action 1:Action |
| 1.3.6.1.4.1.4756.20.481.40.1.83 | Columnf1000EASX2FIpModeRemoteA | read-write | current | On Rack Ip Mode: 0:Enable 1:Disable |
| 1.3.6.1.4.1.4756.20.481.40.1.84 | Columnf1000EASX2FOamChATxRemoteA | read-only | current | RemoteA device OAM Channel A TX OAMPDU frame count |
| 1.3.6.1.4.1.4756.20.481.40.1.85 | Columnf1000EASX2FOamChARxRemoteA | read-only | current | RemoteA device OAM Channel A RX OAMPDU frame count |
| 1.3.6.1.4.1.4756.20.481.40.1.86 | Columnf1000EASX2FOamInfoChATxRemoteA | read-only | current | RemoteA device OAM Channel A TX Information OAMPDU frame count |
| 1.3.6.1.4.1.4756.20.481.40.1.87 | Columnf1000EASX2FOamInfoChARxRemoteA | read-only | current | RemoteA device OAM Channel A RX Information OAMPDU frame count |
| 1.3.6.1.4.1.4756.20.481.40.1.88 | Columnf1000EASX2FOamEventChATxRemoteA | read-only | current | RemoteA device OAM Channel A TX Event OAMPDU frame count |
| 1.3.6.1.4.1.4756.20.481.40.1.89 | Columnf1000EASX2FOamUniEvtChARxRemoteA | read-only | current | RemoteA device OAM Channel A RX Unique Event OAMPDU frame count |
| 1.3.6.1.4.1.4756.20.481.40.1.90 | Columnf1000EASX2FOamDupEvtChARxRemoteA | read-only | current | RemoteA device OAM Channel A RX Duplicate Event OAMPDU frame count |
| 1.3.6.1.4.1.4756.20.481.40.1.91 | Columnf1000EASX2FOamLbChATxRemoteA | read-only | current | RemoteA device OAM Channel A TX Loopback Control OAMPDU frame count |
| 1.3.6.1.4.1.4756.20.481.40.1.92 | Columnf1000EASX2FOamLbChARxRemoteA | read-only | current | RemoteA device OAM Channel A RX Loopback Control OAMPDU frame count |
| 1.3.6.1.4.1.4756.20.481.40.1.93 | Columnf1000EASX2FOamVarReqChATxRemoteA | read-only | current | RemoteA device OAM Channel A TX Variable Request OAMPDU frame count |
| 1.3.6.1.4.1.4756.20.481.40.1.94 | Columnf1000EASX2FOamVarReqChARxRemoteA | read-only | current | RemoteA device OAM Channel A RX Variable Request OAMPDU frame count |
| 1.3.6.1.4.1.4756.20.481.40.1.95 | Columnf1000EASX2FOamVarRspChATxRemoteA | read-only | current | RemoteA device OAM Channel A TX Variable Response OAMPDU frame count |
| 1.3.6.1.4.1.4756.20.481.40.1.96 | Columnf1000EASX2FOamVarRspChARxRemoteA | read-only | current | RemoteA device OAM Channel A RX Variable Response OAMPDU frame count |
| 1.3.6.1.4.1.4756.20.481.40.1.97 | Columnf1000EASX2FOamOuiChATxRemoteA | read-only | current | RemoteA device OAM Channel A TX OUI OAMPDU frame count |
| 1.3.6.1.4.1.4756.20.481.40.1.98 | Columnf1000EASX2FOamOuiChARxRemoteA | read-only | current | RemoteA device OAM Channel A RX OUI OAMPDU frame count |
| 1.3.6.1.4.1.4756.20.481.40.1.99 | Columnf1000EASX2FOamUnknowChARxRemoteA | read-only | current | RemoteA device OAM Channel A RX Unsupported OAMPDU frame count |
| 1.3.6.1.4.1.4756.20.481.40.1.100 | Columnf1000EASX2FOamChBTxRemoteA | read-only | current | RemoteA device OAM Channel B TX OAMPDU frame count |
| 1.3.6.1.4.1.4756.20.481.40.1.101 | Columnf1000EASX2FOamChBRxRemoteA | read-only | current | RemoteA device OAM Channel B RX OAMPDU frame count |
| 1.3.6.1.4.1.4756.20.481.40.1.102 | Columnf1000EASX2FOamInfoChBTxRemoteA | read-only | current | RemoteA device OAM Channel B TX Information OAMPDU frame count |
| 1.3.6.1.4.1.4756.20.481.40.1.103 | Columnf1000EASX2FOamInfoChBRxRemoteA | read-only | current | RemoteA device OAM Channel B RX Information OAMPDU frame count |
| 1.3.6.1.4.1.4756.20.481.40.1.104 | Columnf1000EASX2FOamEventChBTxRemoteA | read-only | current | RemoteA device OAM Channel B TX Event OAMPDU frame count |
| 1.3.6.1.4.1.4756.20.481.40.1.105 | Columnf1000EASX2FOamUniEvtChBRxRemoteA | read-only | current | RemoteA device OAM Channel B RX Unique Event OAMPDU frame count |
| 1.3.6.1.4.1.4756.20.481.40.1.106 | Columnf1000EASX2FOamDupEvtChBRxRemoteA | read-only | current | RemoteA device OAM Channel B RX Duplicate Event OAMPDU frame count |
| 1.3.6.1.4.1.4756.20.481.40.1.107 | Columnf1000EASX2FOamLbChBTxRemoteA | read-only | current | RemoteA device OAM Channel B TX Loopback Control OAMPDU frame count |
| 1.3.6.1.4.1.4756.20.481.40.1.108 | Columnf1000EASX2FOamLbChBRxRemoteA | read-only | current | RemoteA device OAM Channel B RX Loopback Control OAMPDU frame count |
| 1.3.6.1.4.1.4756.20.481.40.1.109 | Columnf1000EASX2FOamVarReqChBTxRemoteA | read-only | current | RemoteA device OAM Channel B TX Variable Request OAMPDU frame count |
| 1.3.6.1.4.1.4756.20.481.40.1.110 | Columnf1000EASX2FOamVarReqChBRxRemoteA | read-only | current | RemoteA device OAM Channel B RX Variable Request OAMPDU frame count |
| 1.3.6.1.4.1.4756.20.481.40.1.111 | Columnf1000EASX2FOamVarRspChBTxRemoteA | read-only | current | RemoteA device OAM Channel B TX Variable Response OAMPDU frame count |
| 1.3.6.1.4.1.4756.20.481.40.1.112 | Columnf1000EASX2FOamVarRspChBRxRemoteA | read-only | current | RemoteA device OAM Channel B RX Variable Response OAMPDU frame count |
| 1.3.6.1.4.1.4756.20.481.40.1.113 | Columnf1000EASX2FOamOuiChBTxRemoteA | read-only | current | RemoteA device OAM Channel B TX OUI OAMPDU frame count |
| 1.3.6.1.4.1.4756.20.481.40.1.114 | Columnf1000EASX2FOamOuiChBRxRemoteA | read-only | current | RemoteA device OAM Channel B RX OUI OAMPDU frame count |
| 1.3.6.1.4.1.4756.20.481.40.1.115 | Columnf1000EASX2FOamUnknowChBRxRemoteA | read-only | current | RemoteA device OAM Channel B RX Unsupported OAMPDU frame count |
| 1.3.6.1.4.1.4756.20.481.40.1.116 | Columnf1000EASX2FFiber1SpeedRemoteA | read-only | current | RemoteA device Fiber 1 speed : 0:1000Auto 1:1000FDX 2:100FDX |
| 1.3.6.1.4.1.4756.20.481.40.1.117 | Columnf1000EASX2FFiber2SpeedRemoteA | read-only | current | RemoteA device Fiber 2 speed : 0:1000Auto 1:1000FDX 2:100FDX |
| 1.3.6.1.4.1.4756.20.481.40.1.118 | Columnf1000EASX2FMacLearningRemoteA | read-write | current | RemoteA device Mac learning : 0:Disable 1:Enable |
| 1.3.6.1.4.1.4756.20.481.40.1.119 | Columnf1000EASX2FManagementVIDRemoteA | read-write | current | RemoteA device Management VID : |
| 1.3.6.1.4.1.4756.20.481.40.1.120 | Columnf1000EASX2FTagTypeRemoteA | read-write | current | RemoteA device Tag Type (HEX) : |
| 1.3.6.1.4.1.4756.20.481.40.1.121 | Columnf1000EASX2FPort1VIDRemoteA | read-write | current | RemoteA device Port 1 VID : |
| 1.3.6.1.4.1.4756.20.481.40.1.122 | Columnf1000EASX2FPort2VIDRemoteA | read-write | current | RemoteA device Port 2 VID : |
| 1.3.6.1.4.1.4756.20.481.40.1.123 | Columnf1000EASX2FPort1QinQRemoteA | read-write | current | RemoteA device Port 1 Q in Q Support : 1:Disable 2:Enable |
| 1.3.6.1.4.1.4756.20.481.40.1.124 | Columnf1000EASX2FPort2QinQRemoteA | read-write | current | RemoteA device Port 2 Q in Q Support : 1:Disable 2:Enable |
| 1.3.6.1.4.1.4756.20.481.40.1.125 | Columnf1000EASX2FVID1RemoteA | read-write | current | RemoteA device VID 1: |
| 1.3.6.1.4.1.4756.20.481.40.1.126 | Columnf1000EASX2FVID2RemoteA | read-write | current | RemoteA device VID 2: |
| 1.3.6.1.4.1.4756.20.481.40.1.127 | Columnf1000EASX2FVID3RemoteA | read-write | current | RemoteA device VID 3: |
| 1.3.6.1.4.1.4756.20.481.40.1.128 | Columnf1000EASX2FVID4RemoteA | read-write | current | RemoteA device VID 4: |
| 1.3.6.1.4.1.4756.20.481.40.1.129 | Columnf1000EASX2FVID5RemoteA | read-write | current | RemoteA device VID 5: |
| 1.3.6.1.4.1.4756.20.481.40.1.130 | Columnf1000EASX2FVID6RemoteA | read-write | current | RemoteA device VID 6: |
| 1.3.6.1.4.1.4756.20.481.40.1.131 | Columnf1000EASX2FVID7RemoteA | read-write | current | RemoteA device VID 7: |
| 1.3.6.1.4.1.4756.20.481.40.1.132 | Columnf1000EASX2FVID8RemoteA | read-write | current | RemoteA device VID 8: |
| 1.3.6.1.4.1.4756.20.481.40.1.133 | Columnf1000EASX2FVID9RemoteA | read-write | current | RemoteA device VID 9: |
| 1.3.6.1.4.1.4756.20.481.40.1.134 | Columnf1000EASX2FVID10RemoteA | read-write | current | RemoteA device VID 10: |
| 1.3.6.1.4.1.4756.20.481.40.1.135 | Columnf1000EASX2FVID11RemoteA | read-write | current | RemoteA device VID 11: |
| 1.3.6.1.4.1.4756.20.481.40.1.136 | Columnf1000EASX2FVID12RemoteA | read-write | current | RemoteA device VID 12: |
| 1.3.6.1.4.1.4756.20.481.40.1.137 | Columnf1000EASX2FVID13RemoteA | read-write | current | RemoteA device VID 13: |
| 1.3.6.1.4.1.4756.20.481.40.1.138 | Columnf1000EASX2FVID14RemoteA | read-write | current | RemoteA device VID 14: |
| 1.3.6.1.4.1.4756.20.481.40.1.139 | Columnf1000EASX2FVID15RemoteA | read-write | current | RemoteA device VID 15: |
| 1.3.6.1.4.1.4756.20.481.40.1.140 | Columnf1000EASX2FVID16RemoteA | read-write | current | RemoteA device VID 16: |
| 1.3.6.1.4.1.4756.20.481.40.1.141 | Columnf1000EASX2FPort1Member1RemoteA | read-write | current | RemoteA device card port 1 member: 0:Unmodify 1:Untagged 2:Tagged 3:Nonmember |
| 1.3.6.1.4.1.4756.20.481.40.1.142 | Columnf1000EASX2FPort1Member2RemoteA | read-write | current | RemoteA device card port 1 member 2: 0:Unmodify 1:Untagged 2:Tagged 3:Nonmember |
| 1.3.6.1.4.1.4756.20.481.40.1.143 | Columnf1000EASX2FPort1Member3RemoteA | read-write | current | RemoteA device card port 1 member 3: 0:Unmodify 1:Untagged 2:Tagged 3:Nonmember |
| 1.3.6.1.4.1.4756.20.481.40.1.144 | Columnf1000EASX2FPort1Member4RemoteA | read-write | current | RemoteA device card port 1 member 4: 0:Unmodify 1:Untagged 2:Tagged 3:Nonmember |
| 1.3.6.1.4.1.4756.20.481.40.1.145 | Columnf1000EASX2FPort1Member5RemoteA | read-write | current | RemoteA device card port 1 member 5: 0:Unmodify 1:Untagged 2:Tagged 3:Nonmember |
| 1.3.6.1.4.1.4756.20.481.40.1.146 | Columnf1000EASX2FPort1Member6RemoteA | read-write | current | RemoteA device card port 1 member 6: 0:Unmodify 1:Untagged 2:Tagged 3:Nonmember |
| 1.3.6.1.4.1.4756.20.481.40.1.147 | Columnf1000EASX2FPort1Member7RemoteA | read-write | current | RemoteA device card port 1 member 7: 0:Unmodify 1:Untagged 2:Tagged 3:Nonmember |
| 1.3.6.1.4.1.4756.20.481.40.1.148 | Columnf1000EASX2FPort1Member8RemoteA | read-write | current | RemoteA device card port 1 member 8: 0:Unmodify 1:Untagged 2:Tagged 3:Nonmember |
| 1.3.6.1.4.1.4756.20.481.40.1.149 | Columnf1000EASX2FPort1Member9RemoteA | read-write | current | RemoteA device card port 1 member 9: 0:Unmodify 1:Untagged 2:Tagged 3:Nonmember |
| 1.3.6.1.4.1.4756.20.481.40.1.150 | Columnf1000EASX2FPort1Member10RemoteA | read-write | current | RemoteA device card port 1 member 10: 0:Unmodify 1:Untagged 2:Tagged 3:Nonmember |
| 1.3.6.1.4.1.4756.20.481.40.1.151 | Columnf1000EASX2FPort1Member11RemoteA | read-write | current | RemoteA device card port 1 member 11: 0:Unmodify 1:Untagged 2:Tagged 3:Nonmember |
| 1.3.6.1.4.1.4756.20.481.40.1.152 | Columnf1000EASX2FPort1Member12RemoteA | read-write | current | RemoteA device card port 1 member 12: 0:Unmodify 1:Untagged 2:Tagged 3:Nonmember |
| 1.3.6.1.4.1.4756.20.481.40.1.153 | Columnf1000EASX2FPort1Member13RemoteA | read-write | current | RemoteA device card port 1 member 13: 0:Unmodify 1:Untagged 2:Tagged 3:Nonmember |
| 1.3.6.1.4.1.4756.20.481.40.1.154 | Columnf1000EASX2FPort1Member14RemoteA | read-write | current | RemoteA device card port 1 member 14: 0:Unmodify 1:Untagged 2:Tagged 3:Nonmember |
| 1.3.6.1.4.1.4756.20.481.40.1.155 | Columnf1000EASX2FPort1Member15RemoteA | read-write | current | RemoteA device card port 1 member 15: 0:Unmodify 1:Untagged 2:Tagged 3:Nonmember |
| 1.3.6.1.4.1.4756.20.481.40.1.156 | Columnf1000EASX2FPort1Member16RemoteA | read-write | current | RemoteA device card port 1 member 16: 0:Unmodify 1:Untagged 2:Tagged 3:Nonmember |
| 1.3.6.1.4.1.4756.20.481.40.1.157 | Columnf1000EASX2FPort2Member1RemoteA | read-write | current | RemoteA device card port 2 member: 0:Unmodify 1:Untagged 2:Tagged 3:Nonmember |
| 1.3.6.1.4.1.4756.20.481.40.1.158 | Columnf1000EASX2FPort2Member2RemoteA | read-write | current | RemoteA device card port 2 member 2: 0:Unmodify 1:Untagged 2:Tagged 3:Nonmember |
| 1.3.6.1.4.1.4756.20.481.40.1.159 | Columnf1000EASX2FPort2Member3RemoteA | read-write | current | RemoteA device card port 2 member 3: 0:Unmodify 1:Untagged 2:Tagged 3:Nonmember |
| 1.3.6.1.4.1.4756.20.481.40.1.160 | Columnf1000EASX2FPort2Member4RemoteA | read-write | current | RemoteA device card port 2 member 4: 0:Unmodify 1:Untagged 2:Tagged 3:Nonmember |
| 1.3.6.1.4.1.4756.20.481.40.1.161 | Columnf1000EASX2FPort2Member5RemoteA | read-write | current | RemoteA device card port 2 member 5: 0:Unmodify 1:Untagged 2:Tagged 3:Nonmember |
| 1.3.6.1.4.1.4756.20.481.40.1.162 | Columnf1000EASX2FPort2Member6RemoteA | read-write | current | RemoteA device card port 2 member 6: 0:Unmodify 1:Untagged 2:Tagged 3:Nonmember |
| 1.3.6.1.4.1.4756.20.481.40.1.163 | Columnf1000EASX2FPort2Member7RemoteA | read-write | current | RemoteA device card port 2 member 7: 0:Unmodify 1:Untagged 2:Tagged 3:Nonmember |
| 1.3.6.1.4.1.4756.20.481.40.1.164 | Columnf1000EASX2FPort2Member8RemoteA | read-write | current | RemoteA device card port 2 member 8: 0:Unmodify 1:Untagged 2:Tagged 3:Nonmember |
| 1.3.6.1.4.1.4756.20.481.40.1.165 | Columnf1000EASX2FPort2Member9RemoteA | read-write | current | RemoteA device card port 2 member 9: 0:Unmodify 1:Untagged 2:Tagged 3:Nonmember |
| 1.3.6.1.4.1.4756.20.481.40.1.166 | Columnf1000EASX2FPort2Member10RemoteA | read-write | current | RemoteA device card port 2 member 10: 0:Unmodify 1:Untagged 2:Tagged 3:Nonmember |
| 1.3.6.1.4.1.4756.20.481.40.1.167 | Columnf1000EASX2FPort2Member11RemoteA | read-write | current | RemoteA device card port 2 member 11: 0:Unmodify 1:Untagged 2:Tagged 3:Nonmember |
| 1.3.6.1.4.1.4756.20.481.40.1.168 | Columnf1000EASX2FPort2Member12RemoteA | read-write | current | RemoteA device card port 2 member 12: 0:Unmodify 1:Untagged 2:Tagged 3:Nonmember |
| 1.3.6.1.4.1.4756.20.481.40.1.169 | Columnf1000EASX2FPort2Member13RemoteA | read-write | current | RemoteA device card port 2 member 13: 0:Unmodify 1:Untagged 2:Tagged 3:Nonmember |
| 1.3.6.1.4.1.4756.20.481.40.1.170 | Columnf1000EASX2FPort2Member14RemoteA | read-write | current | RemoteA device card port 2 member 14: 0:Unmodify 1:Untagged 2:Tagged 3:Nonmember |
| 1.3.6.1.4.1.4756.20.481.40.1.171 | Columnf1000EASX2FPort2Member15RemoteA | read-write | current | RemoteA device card port 2 member 15: 0:Unmodify 1:Untagged 2:Tagged 3:Nonmember |
| 1.3.6.1.4.1.4756.20.481.40.1.172 | Columnf1000EASX2FPort2Member16RemoteA | read-write | current | RemoteA device card port 2 member 16: 0:Unmodify 1:Untagged 2:Tagged 3:Nonmember |
| 1.3.6.1.4.1.4756.20.481.40.1.173 | Columnf1000EASX2FIpAddressRemoteA | read-write | current | RemoteA device IP address |
| 1.3.6.1.4.1.4756.20.481.40.1.174 | Columnf1000EASX2FNetMaskRemoteA | read-write | current | RemoteA device Netmask |
| 1.3.6.1.4.1.4756.20.481.40.1.175 | Columnf1000EASX2FGateWayRemoteA | read-write | current | RemoteA device Gateway |
| 1.3.6.1.4.1.4756.20.481.40.1.176 | Columnf1000EASX2FSetDefaultRemoteA | read-write | current | RemoteA device set to default |
| 1.3.6.1.4.1.4756.20.481.40.1.177 | Columnf1000EASX2FFx1LinkAlarmRemoteA | read-write | current | RemoteA device fiber 1 link alarm 0:Disable 1:Enable |
| 1.3.6.1.4.1.4756.20.481.40.1.178 | Columnf1000EASX2FFx2LinkAlarmRemoteA | read-write | current | RemoteA device fiber 2 link alarm 0:Disable 1:Enable |
| 1.3.6.1.4.1.4756.20.481.40.1.179 | Columnf1000EASX2FFHRModeRemoteA | read-write | current | RemoteA device card FHR Mode: 0:Disable 1:Enable |
| 1.3.6.1.4.1.4756.20.481.40.1.180 | Columnf1000EASX2FRemoteTLPTRemoteA | read-write | current | RemoteA device Remote TLPT mode : 0:Disalbe 1:Remote A 2:Remote B |
| 1.3.6.1.4.1.4756.20.482 | Nodef1000EASX2FRemoteBCards | |||
| 1.3.6.1.4.1.4756.20.482.40 | Tablef1000EASX2FRemoteBTable | not-accessible | current | A list of RemoteB 1000EAS/X-2F card entries. |
| 1.3.6.1.4.1.4756.20.482.40.1 | Rowf1000EASX2FRemoteBEntry | not-accessible | current | An entry containing management information applicable to a particular RemoteB 1000EAS/X-2F card. |
| 1.3.6.1.4.1.4756.20.482.40.1.1 | Columnf1000EASX2FChassisIndexRemoteB | read-only | current | A unique value for each chassis ID. For CH20, it is the chassis ID. For CH08, it is always 0. |
| 1.3.6.1.4.1.4756.20.482.40.1.2 | Columnf1000EASX2FSlotIndexRemoteB | read-only | current | A unique value for each local card. It is the slot location number. |
| 1.3.6.1.4.1.4756.20.482.40.1.3 | Columnf1000EASX2FCardHWVerRemoteB | read-only | current | RemoteB device card hardware version x.xxx |
| 1.3.6.1.4.1.4756.20.482.40.1.4 | Columnf1000EASX2FCardFWVerRemoteB | read-only | current | RemoteB device card firmware version x.xxx |
| 1.3.6.1.4.1.4756.20.482.40.1.5 | Columnf1000EASX2FCardCPLDVerRemoteB | read-only | current | RemoteB device card CPLD version x.xxx |
| 1.3.6.1.4.1.4756.20.482.40.1.6 | Columnf1000EASX2FCardFPGAVerRemoteB | read-only | current | RemoteB device card FPGA version x.xxx |
| 1.3.6.1.4.1.4756.20.482.40.1.7 | Columnf1000EASX2FModelRemoteB | read-only | current | RemoteB 1000EAS/X Serial Type |
| 1.3.6.1.4.1.4756.20.482.40.1.8 | Columnf1000EASX2FFiber1LinkRemoteB | read-only | current | RemoteB device card fiber port 1 link status: 0:Down 1:Up |
| 1.3.6.1.4.1.4756.20.482.40.1.9 | Columnf1000EASX2FFiber1OAMLoopedRemoteB | read-only | current | RemoteB device card fiber port 1 OAM looped: 0:Off 1:on |
| 1.3.6.1.4.1.4756.20.482.40.1.10 | Columnf1000EASX2FFiber1LBTestRemoteB | read-write | current | Force remote device card to do fiber port 1 LoopBack testing: 0:Off 1:Action |
| 1.3.6.1.4.1.4756.20.482.40.1.11 | Columnf1000EASX2FFiber1OAMRLBStatusRemoteB | read-only | current | Remote device card fiber port 1 LoopBack testing status: 0:Off 1:Ok 2:Fail |
| 1.3.6.1.4.1.4756.20.482.40.1.12 | Columnf1000EASX2FFiber1RemoPwrAbRemoteB | read-only | current | RemoteB device card fiber port 1 Remote Power status: 0:Abnormal 1:OK 2:None |
| 1.3.6.1.4.1.4756.20.482.40.1.13 | Columnf1000EASX2FFiber1IngressRateRemoteB | read-write | current | RemoteB device card fiber 1 Ingress Rate Limit: 0 = Unlimit input format: 64k(K),100m(M),100 If doesn't input the unit, the default was Mega. Limite Rate : 64K… |
| 1.3.6.1.4.1.4756.20.482.40.1.14 | Columnf1000EASX2FFiber1EgressRateRemoteB | read-write | current | RemoteB device card fiber 1 Egress Rate Limit: 0 = Unlimit input format: 64k(K),100m(M),100 If doesn't input the unit, the default was Mega. Limite Rate : 64K … |
| 1.3.6.1.4.1.4756.20.482.40.1.15 | Columnf1000EASX2FFiber2LinkRemoteB | read-only | current | RemoteB device card fiber port 2 link status: 0:Down 1:Up |
| 1.3.6.1.4.1.4756.20.482.40.1.16 | Columnf1000EASX2FFiber2OAMLoopedRemoteB | read-only | current | RemoteB device card fiber port 2 OAM looped: 0:Off 1:on |
| 1.3.6.1.4.1.4756.20.482.40.1.17 | Columnf1000EASX2FFiber2LBTestRemoteB | read-write | current | Force remote device card to do fiber port 2 LoopBack testing: 0:Off 1:Action |
| 1.3.6.1.4.1.4756.20.482.40.1.18 | Columnf1000EASX2FFiber2OAMRLBStatusRemoteB | read-only | current | Remote device card fiber port 1 LoopBack testing status: 0:Off 1:Ok 2:Fail |
| 1.3.6.1.4.1.4756.20.482.40.1.19 | Columnf1000EASX2FFiber2RemoPwrAbRemoteB | read-only | current | RemoteB device card fiber port 2 Remote Power status: 0:Abnormal 1:OK 2:None |
| 1.3.6.1.4.1.4756.20.482.40.1.20 | Columnf1000EASX2FFiber2IngressRateRemoteB | read-write | current | RemoteB device card fiber 2 Ingress Rate Limit: 0 = Unlimit input format: 64k(K),100m(M),100 If doesn't input the unit, the default was Mega. Limite Rate : 64K… |
| 1.3.6.1.4.1.4756.20.482.40.1.21 | Columnf1000EASX2FFiber2EgressRateRemoteB | read-write | current | RemoteB device card fiber 2 Egress Rate Limit: 0 = Unlimit input format: 64k(K),100m(M),100 If doesn't input the unit, the default was Mega. Limite Rate : 64K … |
| 1.3.6.1.4.1.4756.20.482.40.1.22 | Columnf1000EASX2FFiber1FEFRemoteB | read-only | current | RemoteB device card fiber1 port FEF status: 0:Off 1:Detected |
| 1.3.6.1.4.1.4756.20.482.40.1.23 | Columnf1000EASX2FFiber2FEFRemoteB | read-only | current | RemoteB device card fiber2 port FEF status: 0:Off 1:Detected |
| 1.3.6.1.4.1.4756.20.482.40.1.24 | Columnf1000EASX2FDeviceActiveRemoteB | read-only | current | RemoteB device card active mode: (It is read-only in local device.) 0:Disable 1:Enable |
| 1.3.6.1.4.1.4756.20.482.40.1.25 | Columnf1000EASX2FDeviceResetRemoteB | read-write | current | Force local device card to reset mode: 0:Off 1:Action |
| 1.3.6.1.4.1.4756.20.482.40.1.26 | Columnf1000EASX2FFiber1ActiveRemoteB | read-write | current | RemoteB device fiber port 1 active mode: 0:Disable 1:Enable |
| 1.3.6.1.4.1.4756.20.482.40.1.27 | Columnf1000EASX2FFiber2ActiveRemoteB | read-write | current | RemoteB device fiber port 2 active mode: 0:Disable 1:Enable |
| 1.3.6.1.4.1.4756.20.482.40.1.28 | Columnf1000EASX2FOamChAModeRemoteB | read-write | current | RemoteB device OAM Channel A mode: 0:Disable 1:passive 2:Active |
| 1.3.6.1.4.1.4756.20.482.40.1.29 | Columnf1000EASX2FOamChBModeRemoteB | read-write | current | RemoteB device OAM Channel B mode: 0:Disable 1:passive 2:Active |
| 1.3.6.1.4.1.4756.20.482.40.1.30 | Columnf1000EASX2FOamMaxPDUsRemoteB | read-write | current | RemoteB device OAM max OAMPDU size: 60-1518 Octets |
| 1.3.6.1.4.1.4756.20.482.40.1.31 | Columnf1000EASX2FFiber1AlsRemoteB | read-write | current | RemoteB device card port 1 Auto Laser Shutdown mode: 0:Disable 1:Enable |
| 1.3.6.1.4.1.4756.20.482.40.1.32 | Columnf1000EASX2FFiber2AlsRemoteB | read-write | current | RemoteB device card port 2 Auto Laser Shutdown mode: 0:Disable 1:Enable |
| 1.3.6.1.4.1.4756.20.482.40.1.33 | Columnf1000EASX2FPauseFrameRemoteB | read-write | current | RemoteB device card pause frame mode: 0:Disable 1:Enable |
| 1.3.6.1.4.1.4756.20.482.40.1.34 | Columnf1000EASX2FSendFHRtoARemoteB | read-write | current | RemoteB device card port 1 send Fiber Hardware Reset to remote: 0:No action 1:Action |
| 1.3.6.1.4.1.4756.20.482.40.1.35 | Columnf1000EASX2FSendFHRtoBRemoteB | read-write | current | RemoteB device card port 2 send Fiber Hardware Reset to remote: 0:No action 1:Action |
| 1.3.6.1.4.1.4756.20.482.40.1.36 | Columnf1000EASX2FFiber1LLFDepPort2RemoteB | read-write | current | RemoteB device card port 1 Link Loss Forwarding depends on port 2 Fiber Rx link: 0:don't care 1:selected |
| 1.3.6.1.4.1.4756.20.482.40.1.37 | Columnf1000EASX2FFiber2LLFDepPort1RemoteB | read-write | current | RemoteB device card port 2 Link Loss Forwarding depends on port 1 Fiber Rx link: 0:don't care 1:selected |
| 1.3.6.1.4.1.4756.20.482.40.1.38 | Columnf1000EASX2FAdvanceFunsRemoteB | read-write | current | RemoteB device card Switch functions mode: 0:Normal 5:Static 802.1Q VLAN 6:Spanning Tree Protocol 7:802.1Q VLAN Trunk 9:Q in Q VLAN 11:Spanning Tree Protocol a… |
| 1.3.6.1.4.1.4756.20.482.40.1.39 | Columnf1000EASX2FFiber1InfoROM1RemoteB | read-only | current | RemoteB device card port 1 INFORemoteOM information 1 valid: 0:Invalid 1:Valid |
| 1.3.6.1.4.1.4756.20.482.40.1.40 | Columnf1000EASX2FFiber1InfoROM2RemoteB | read-only | current | RemoteB device card port 1 INFORemoteOM information 2 valid: 0:Invalid 1:Valid(replacing D/D function |
| 1.3.6.1.4.1.4756.20.482.40.1.41 | Columnf1000EASX2FFiber2InfoROM1RemoteB | read-only | current | RemoteB device card port 2 INFORemoteOM information 1 valid: 0:Invalid 1:Valid |
| 1.3.6.1.4.1.4756.20.482.40.1.42 | Columnf1000EASX2FFiber2InfoROM2RemoteB | read-only | current | RemoteB device card port 2 INFORemoteOM information 2 valid: 0:Invalid 1:Valid(replacing D/D function) |
| 1.3.6.1.4.1.4756.20.482.40.1.43 | Columnf1000EASX2FFiber1InfoSN1RemoteB | read-only | current | RemoteB device card port 1 INFORemoteOM S/N 1 |
| 1.3.6.1.4.1.4756.20.482.40.1.44 | Columnf1000EASX2FFiber1InfoSN2RemoteB | read-only | current | RemoteB device card port 1 INFORemoteOM S/N 2 |
| 1.3.6.1.4.1.4756.20.482.40.1.45 | Columnf1000EASX2FFiber2InfoSN1RemoteB | read-only | current | RemoteB device card port 2 INFORemoteOM S/N 1 |
| 1.3.6.1.4.1.4756.20.482.40.1.46 | Columnf1000EASX2FFiber2InfoSN2RemoteB | read-only | current | RemoteB device card port 2 INFORemoteOM S/N 2 |
| 1.3.6.1.4.1.4756.20.482.40.1.47 | Columnf1000EASX2FFiber1DDRemoteB | read-only | current | RemoteB device card fiber port 1 Digital Diagnostic function: 0:No 1:Yes |
| 1.3.6.1.4.1.4756.20.482.40.1.48 | Columnf1000EASX2FFiber1DDVendorRemoteB | read-only | current | RemoteB device card fiber port 1 D/D information: Vendor name |
| 1.3.6.1.4.1.4756.20.482.40.1.49 | Columnf1000EASX2FFiber1DDPartNoRemoteB | read-only | current | RemoteB device card fiber port 1 D/D information: Vendor part number |
| 1.3.6.1.4.1.4756.20.482.40.1.50 | Columnf1000EASX2FFiber1DDFiberTypeRemoteB | read-only | current | RemoteB device card fiber port 1 D/D information: Fiber Type |
| 1.3.6.1.4.1.4756.20.482.40.1.51 | Columnf1000EASX2FFiber1DDWaveLenRemoteB | read-only | current | RemoteB device card fiber port 1 D/D information: Wave length |
| 1.3.6.1.4.1.4756.20.482.40.1.52 | Columnf1000EASX2FFiber1DDWaveLen2RemoteB | read-only | current | RemoteB device card fiber port 1 D/D information: Wave length 2 |
| 1.3.6.1.4.1.4756.20.482.40.1.53 | Columnf1000EASX2FFiber1DDLinkLenRemoteB | read-only | current | RemoteB device card fiber port 1 D/D information: Link length |
| 1.3.6.1.4.1.4756.20.482.40.1.54 | Columnf1000EASX2FFiber1DDLenUnitRemoteB | read-only | current | RemoteB device card fiber port 1 D/D information: Length Unit |
| 1.3.6.1.4.1.4756.20.482.40.1.55 | Columnf1000EASX2FFiber1DDStatusRemoteB | read-only | current | RemoteB device card fiber port 1 D/D information: Status Support |
| 1.3.6.1.4.1.4756.20.482.40.1.56 | Columnf1000EASX2FFiber1DDRxSensRemoteB | read-only | current | RemoteB device card fiber port 1 D/D information: Rx Sensitivity |
| 1.3.6.1.4.1.4756.20.482.40.1.57 | Columnf1000EASX2FFiber1DDTxPWRRemoteB | read-only | current | RemoteB device card fiber port 1 D/D information: Tx power |
| 1.3.6.1.4.1.4756.20.482.40.1.58 | Columnf1000EASX2FFiber1DDRxPWRRemoteB | read-only | current | RemoteB device card fiber port 1 D/D information: Rx power |
| 1.3.6.1.4.1.4756.20.482.40.1.59 | Columnf1000EASX2FFiber1DDTempRemoteB | read-only | current | RemoteB device card fiber port 1 D/D information: Temperature in degree C |
| 1.3.6.1.4.1.4756.20.482.40.1.60 | Columnf1000EASX2FFiber1DDPWRMarginRemoteB | read-only | current | RemoteB device card fiber port 1 D/D information: Power margin |
| 1.3.6.1.4.1.4756.20.482.40.1.61 | Columnf1000EASX2FFiber1DDPWRLossRemoteB | read-only | current | RemoteB device card fiber port 1 D/D information: Power loss |
| 1.3.6.1.4.1.4756.20.482.40.1.62 | Columnf1000EASX2FFiber2DDRemoteB | read-only | current | RemoteB device card fiber port 2 Digital Diagnostic function: 0:No 1:Yes |
| 1.3.6.1.4.1.4756.20.482.40.1.63 | Columnf1000EASX2FFiber2DDVendorRemoteB | read-only | current | RemoteB device card fiber port 2 D/D information: Vendor name |
| 1.3.6.1.4.1.4756.20.482.40.1.64 | Columnf1000EASX2FFiber2DDPartNoRemoteB | read-only | current | RemoteB device card fiber port 2 D/D information: Vendor part number |
| 1.3.6.1.4.1.4756.20.482.40.1.65 | Columnf1000EASX2FFiber2DDFiberTypeRemoteB | read-only | current | RemoteB device card fiber port 2 D/D information: Fiber Type |
| 1.3.6.1.4.1.4756.20.482.40.1.66 | Columnf1000EASX2FFiber2DDWaveLenRemoteB | read-only | current | RemoteB device card fiber port 2 D/D information: Wave length |
| 1.3.6.1.4.1.4756.20.482.40.1.67 | Columnf1000EASX2FFiber2DDWaveLen2RemoteB | read-only | current | RemoteB device card fiber port 2 D/D information: Wave length 2 |
| 1.3.6.1.4.1.4756.20.482.40.1.68 | Columnf1000EASX2FFiber2DDLinkLenRemoteB | read-only | current | RemoteB device card fiber port 2 D/D information: Link length |
| 1.3.6.1.4.1.4756.20.482.40.1.69 | Columnf1000EASX2FFiber2DDLenUnitRemoteB | read-only | current | RemoteB device card fiber port 2 D/D information: Length Unit |
| 1.3.6.1.4.1.4756.20.482.40.1.70 | Columnf1000EASX2FFiber2DDStatusRemoteB | read-only | current | RemoteB device card fiber port 2 D/D information: Status Support |
| 1.3.6.1.4.1.4756.20.482.40.1.71 | Columnf1000EASX2FFiber2DDRxSensRemoteB | read-only | current | RemoteB device card fiber port 2 D/D information: Rx Sensitivity |
| 1.3.6.1.4.1.4756.20.482.40.1.72 | Columnf1000EASX2FFiber2DDTxPWRRemoteB | read-only | current | RemoteB device card fiber port 2 D/D information: Tx power |
| 1.3.6.1.4.1.4756.20.482.40.1.73 | Columnf1000EASX2FFiber2DDRxPWRRemoteB | read-only | current | RemoteB device card fiber port 2 D/D information: Rx power |
| 1.3.6.1.4.1.4756.20.482.40.1.74 | Columnf1000EASX2FFiber2DDTempRemoteB | read-only | current | RemoteB device card fiber port 2 D/D information: Temperature in degree C |
| 1.3.6.1.4.1.4756.20.482.40.1.75 | Columnf1000EASX2FFiber2DDPWRMarginRemoteB | read-only | current | RemoteB device card fiber port 2 D/D information: Power margin |
| 1.3.6.1.4.1.4756.20.482.40.1.76 | Columnf1000EASX2FFiber2DDPWRLossRemoteB | read-only | current | RemoteB device card fiber port 2 D/D information: Power loss |
| 1.3.6.1.4.1.4756.20.482.40.1.77 | Columnf1000EASX2FClrRMONCntsRemoteB | read-write | current | Clear local device card RMON IN/OUT counters: 0:No action 1:Action |
| 1.3.6.1.4.1.4756.20.482.40.1.78 | Columnf1000EASX2FFiber1RMONInRemoteB | read-only | current | RemoteB device card port 1 RMON IN counter. |
| 1.3.6.1.4.1.4756.20.482.40.1.79 | Columnf1000EASX2FFiber1RMONOutRemoteB | read-only | current | RemoteB device card port 1 RMON OUT counter. |
| 1.3.6.1.4.1.4756.20.482.40.1.80 | Columnf1000EASX2FFiber2RMONInRemoteB | read-only | current | RemoteB device card port 2 RMON IN counter. |
| 1.3.6.1.4.1.4756.20.482.40.1.81 | Columnf1000EASX2FFiber2RMONOutRemoteB | read-only | current | RemoteB device card port 2 RMON OUT counter. |
| 1.3.6.1.4.1.4756.20.482.40.1.82 | Columnf1000EASX2FClrOAMCntsRemoteB | read-write | current | Clear local device card OAM counters: 0:No action 1:Action |
| 1.3.6.1.4.1.4756.20.482.40.1.83 | Columnf1000EASX2FIpModeRemoteB | read-write | current | On Rack Ip Mode: 0:Enable 1:Disable |
| 1.3.6.1.4.1.4756.20.482.40.1.84 | Columnf1000EASX2FOamChATxRemoteB | read-only | current | RemoteB device OAM Channel A TX OAMPDU frame count |
| 1.3.6.1.4.1.4756.20.482.40.1.85 | Columnf1000EASX2FOamChARxRemoteB | read-only | current | RemoteB device OAM Channel A RX OAMPDU frame count |
| 1.3.6.1.4.1.4756.20.482.40.1.86 | Columnf1000EASX2FOamInfoChATxRemoteB | read-only | current | RemoteB device OAM Channel A TX Information OAMPDU frame count |
| 1.3.6.1.4.1.4756.20.482.40.1.87 | Columnf1000EASX2FOamInfoChARxRemoteB | read-only | current | RemoteB device OAM Channel A RX Information OAMPDU frame count |
| 1.3.6.1.4.1.4756.20.482.40.1.88 | Columnf1000EASX2FOamEventChATxRemoteB | read-only | current | RemoteB device OAM Channel A TX Event OAMPDU frame count |
| 1.3.6.1.4.1.4756.20.482.40.1.89 | Columnf1000EASX2FOamUniEvtChARxRemoteB | read-only | current | RemoteB device OAM Channel A RX Unique Event OAMPDU frame count |
| 1.3.6.1.4.1.4756.20.482.40.1.90 | Columnf1000EASX2FOamDupEvtChARxRemoteB | read-only | current | RemoteB device OAM Channel A RX Duplicate Event OAMPDU frame count |
| 1.3.6.1.4.1.4756.20.482.40.1.91 | Columnf1000EASX2FOamLbChATxRemoteB | read-only | current | RemoteB device OAM Channel A TX Loopback Control OAMPDU frame count |
| 1.3.6.1.4.1.4756.20.482.40.1.92 | Columnf1000EASX2FOamLbChARxRemoteB | read-only | current | RemoteB device OAM Channel A RX Loopback Control OAMPDU frame count |
| 1.3.6.1.4.1.4756.20.482.40.1.93 | Columnf1000EASX2FOamVarReqChATxRemoteB | read-only | current | RemoteB device OAM Channel A TX Variable Request OAMPDU frame count |
| 1.3.6.1.4.1.4756.20.482.40.1.94 | Columnf1000EASX2FOamVarReqChARxRemoteB | read-only | current | RemoteB device OAM Channel A RX Variable Request OAMPDU frame count |
| 1.3.6.1.4.1.4756.20.482.40.1.95 | Columnf1000EASX2FOamVarRspChATxRemoteB | read-only | current | RemoteB device OAM Channel A TX Variable Response OAMPDU frame count |
| 1.3.6.1.4.1.4756.20.482.40.1.96 | Columnf1000EASX2FOamVarRspChARxRemoteB | read-only | current | RemoteB device OAM Channel A RX Variable Response OAMPDU frame count |
| 1.3.6.1.4.1.4756.20.482.40.1.97 | Columnf1000EASX2FOamOuiChATxRemoteB | read-only | current | RemoteB device OAM Channel A TX OUI OAMPDU frame count |
| 1.3.6.1.4.1.4756.20.482.40.1.98 | Columnf1000EASX2FOamOuiChARxRemoteB | read-only | current | RemoteB device OAM Channel A RX OUI OAMPDU frame count |
| 1.3.6.1.4.1.4756.20.482.40.1.99 | Columnf1000EASX2FOamUnknowChARxRemoteB | read-only | current | RemoteB device OAM Channel A RX Unsupported OAMPDU frame count |
| 1.3.6.1.4.1.4756.20.482.40.1.100 | Columnf1000EASX2FOamChBTxRemoteB | read-only | current | RemoteB device OAM Channel B TX OAMPDU frame count |
| 1.3.6.1.4.1.4756.20.482.40.1.101 | Columnf1000EASX2FOamChBRxRemoteB | read-only | current | RemoteB device OAM Channel B RX OAMPDU frame count |
| 1.3.6.1.4.1.4756.20.482.40.1.102 | Columnf1000EASX2FOamInfoChBTxRemoteB | read-only | current | RemoteB device OAM Channel B TX Information OAMPDU frame count |
| 1.3.6.1.4.1.4756.20.482.40.1.103 | Columnf1000EASX2FOamInfoChBRxRemoteB | read-only | current | RemoteB device OAM Channel B RX Information OAMPDU frame count |
| 1.3.6.1.4.1.4756.20.482.40.1.104 | Columnf1000EASX2FOamEventChBTxRemoteB | read-only | current | RemoteB device OAM Channel B TX Event OAMPDU frame count |
| 1.3.6.1.4.1.4756.20.482.40.1.105 | Columnf1000EASX2FOamUniEvtChBRxRemoteB | read-only | current | RemoteB device OAM Channel B RX Unique Event OAMPDU frame count |
| 1.3.6.1.4.1.4756.20.482.40.1.106 | Columnf1000EASX2FOamDupEvtChBRxRemoteB | read-only | current | RemoteB device OAM Channel B RX Duplicate Event OAMPDU frame count |
| 1.3.6.1.4.1.4756.20.482.40.1.107 | Columnf1000EASX2FOamLbChBTxRemoteB | read-only | current | RemoteB device OAM Channel B TX Loopback Control OAMPDU frame count |
| 1.3.6.1.4.1.4756.20.482.40.1.108 | Columnf1000EASX2FOamLbChBRxRemoteB | read-only | current | RemoteB device OAM Channel B RX Loopback Control OAMPDU frame count |
| 1.3.6.1.4.1.4756.20.482.40.1.109 | Columnf1000EASX2FOamVarReqChBTxRemoteB | read-only | current | RemoteB device OAM Channel B TX Variable Request OAMPDU frame count |
| 1.3.6.1.4.1.4756.20.482.40.1.110 | Columnf1000EASX2FOamVarReqChBRxRemoteB | read-only | current | RemoteB device OAM Channel B RX Variable Request OAMPDU frame count |
| 1.3.6.1.4.1.4756.20.482.40.1.111 | Columnf1000EASX2FOamVarRspChBTxRemoteB | read-only | current | RemoteB device OAM Channel B TX Variable Response OAMPDU frame count |
| 1.3.6.1.4.1.4756.20.482.40.1.112 | Columnf1000EASX2FOamVarRspChBRxRemoteB | read-only | current | RemoteB device OAM Channel B RX Variable Response OAMPDU frame count |
| 1.3.6.1.4.1.4756.20.482.40.1.113 | Columnf1000EASX2FOamOuiChBTxRemoteB | read-only | current | RemoteB device OAM Channel B TX OUI OAMPDU frame count |
| 1.3.6.1.4.1.4756.20.482.40.1.114 | Columnf1000EASX2FOamOuiChBRxRemoteB | read-only | current | RemoteB device OAM Channel B RX OUI OAMPDU frame count |
| 1.3.6.1.4.1.4756.20.482.40.1.115 | Columnf1000EASX2FOamUnknowChBRxRemoteB | read-only | current | RemoteB device OAM Channel B RX Unsupported OAMPDU frame count |
| 1.3.6.1.4.1.4756.20.482.40.1.116 | Columnf1000EASX2FFiber1SpeedRemoteB | read-only | current | RemoteB device Fiber 1 speed : 0:1000Auto 1:1000FDX 2:100FDX |
| 1.3.6.1.4.1.4756.20.482.40.1.117 | Columnf1000EASX2FFiber2SpeedRemoteB | read-only | current | RemoteB device Fiber 2 speed : 0:1000Auto 1:1000FDX 2:100FDX |
| 1.3.6.1.4.1.4756.20.482.40.1.118 | Columnf1000EASX2FMacLearningRemoteB | read-write | current | RemoteB device Mac learning : 0:Disable 1:Enable |
| 1.3.6.1.4.1.4756.20.482.40.1.119 | Columnf1000EASX2FManagementVIDRemoteB | read-write | current | RemoteB device Management VID : |
| 1.3.6.1.4.1.4756.20.482.40.1.120 | Columnf1000EASX2FTagTypeRemoteB | read-write | current | RemoteB device Tag Type (HEX) : |
| 1.3.6.1.4.1.4756.20.482.40.1.121 | Columnf1000EASX2FPort1VIDRemoteB | read-write | current | RemoteB device Port 1 VID : |
| 1.3.6.1.4.1.4756.20.482.40.1.122 | Columnf1000EASX2FPort2VIDRemoteB | read-write | current | RemoteB device Port 2 VID : |
| 1.3.6.1.4.1.4756.20.482.40.1.123 | Columnf1000EASX2FPort1QinQRemoteB | read-write | current | RemoteB device Port 1 Q in Q Support : 1:Disable 2:Enable |
| 1.3.6.1.4.1.4756.20.482.40.1.124 | Columnf1000EASX2FPort2QinQRemoteB | read-write | current | RemoteB device Port 2 Q in Q Support : 1:Disable 2:Enable |
| 1.3.6.1.4.1.4756.20.482.40.1.125 | Columnf1000EASX2FVID1RemoteB | read-write | current | RemoteB device VID 1: |
| 1.3.6.1.4.1.4756.20.482.40.1.126 | Columnf1000EASX2FVID2RemoteB | read-write | current | RemoteB device VID 2: |
| 1.3.6.1.4.1.4756.20.482.40.1.127 | Columnf1000EASX2FVID3RemoteB | read-write | current | RemoteB device VID 3: |
| 1.3.6.1.4.1.4756.20.482.40.1.128 | Columnf1000EASX2FVID4RemoteB | read-write | current | RemoteB device VID 4: |
| 1.3.6.1.4.1.4756.20.482.40.1.129 | Columnf1000EASX2FVID5RemoteB | read-write | current | RemoteB device VID 5: |
| 1.3.6.1.4.1.4756.20.482.40.1.130 | Columnf1000EASX2FVID6RemoteB | read-write | current | RemoteB device VID 6: |
| 1.3.6.1.4.1.4756.20.482.40.1.131 | Columnf1000EASX2FVID7RemoteB | read-write | current | RemoteB device VID 7: |
| 1.3.6.1.4.1.4756.20.482.40.1.132 | Columnf1000EASX2FVID8RemoteB | read-write | current | RemoteB device VID 8: |
| 1.3.6.1.4.1.4756.20.482.40.1.133 | Columnf1000EASX2FVID9RemoteB | read-write | current | RemoteB device VID 9: |
| 1.3.6.1.4.1.4756.20.482.40.1.134 | Columnf1000EASX2FVID10RemoteB | read-write | current | RemoteB device VID 10: |
| 1.3.6.1.4.1.4756.20.482.40.1.135 | Columnf1000EASX2FVID11RemoteB | read-write | current | RemoteB device VID 11: |
| 1.3.6.1.4.1.4756.20.482.40.1.136 | Columnf1000EASX2FVID12RemoteB | read-write | current | RemoteB device VID 12: |
| 1.3.6.1.4.1.4756.20.482.40.1.137 | Columnf1000EASX2FVID13RemoteB | read-write | current | RemoteB device VID 13: |
| 1.3.6.1.4.1.4756.20.482.40.1.138 | Columnf1000EASX2FVID14RemoteB | read-write | current | RemoteB device VID 14: |
| 1.3.6.1.4.1.4756.20.482.40.1.139 | Columnf1000EASX2FVID15RemoteB | read-write | current | RemoteB device VID 15: |
| 1.3.6.1.4.1.4756.20.482.40.1.140 | Columnf1000EASX2FVID16RemoteB | read-write | current | RemoteB device VID 16: |
| 1.3.6.1.4.1.4756.20.482.40.1.141 | Columnf1000EASX2FPort1Member1RemoteB | read-write | current | RemoteB device card port 1 member: 0:Unmodify 1:Untagged 2:Tagged 3:Nonmember |
| 1.3.6.1.4.1.4756.20.482.40.1.142 | Columnf1000EASX2FPort1Member2RemoteB | read-write | current | RemoteB device card port 1 member 2: 0:Unmodify 1:Untagged 2:Tagged 3:Nonmember |
| 1.3.6.1.4.1.4756.20.482.40.1.143 | Columnf1000EASX2FPort1Member3RemoteB | read-write | current | RemoteB device card port 1 member 3: 0:Unmodify 1:Untagged 2:Tagged 3:Nonmember |
| 1.3.6.1.4.1.4756.20.482.40.1.144 | Columnf1000EASX2FPort1Member4RemoteB | read-write | current | RemoteB device card port 1 member 4: 0:Unmodify 1:Untagged 2:Tagged 3:Nonmember |
| 1.3.6.1.4.1.4756.20.482.40.1.145 | Columnf1000EASX2FPort1Member5RemoteB | read-write | current | RemoteB device card port 1 member 5: 0:Unmodify 1:Untagged 2:Tagged 3:Nonmember |
| 1.3.6.1.4.1.4756.20.482.40.1.146 | Columnf1000EASX2FPort1Member6RemoteB | read-write | current | RemoteB device card port 1 member 6: 0:Unmodify 1:Untagged 2:Tagged 3:Nonmember |
| 1.3.6.1.4.1.4756.20.482.40.1.147 | Columnf1000EASX2FPort1Member7RemoteB | read-write | current | RemoteB device card port 1 member 7: 0:Unmodify 1:Untagged 2:Tagged 3:Nonmember |
| 1.3.6.1.4.1.4756.20.482.40.1.148 | Columnf1000EASX2FPort1Member8RemoteB | read-write | current | RemoteB device card port 1 member 8: 0:Unmodify 1:Untagged 2:Tagged 3:Nonmember |
| 1.3.6.1.4.1.4756.20.482.40.1.149 | Columnf1000EASX2FPort1Member9RemoteB | read-write | current | RemoteB device card port 1 member 9: 0:Unmodify 1:Untagged 2:Tagged 3:Nonmember |
| 1.3.6.1.4.1.4756.20.482.40.1.150 | Columnf1000EASX2FPort1Member10RemoteB | read-write | current | RemoteB device card port 1 member 10: 0:Unmodify 1:Untagged 2:Tagged 3:Nonmember |
| 1.3.6.1.4.1.4756.20.482.40.1.151 | Columnf1000EASX2FPort1Member11RemoteB | read-write | current | RemoteB device card port 1 member 11: 0:Unmodify 1:Untagged 2:Tagged 3:Nonmember |
| 1.3.6.1.4.1.4756.20.482.40.1.152 | Columnf1000EASX2FPort1Member12RemoteB | read-write | current | RemoteB device card port 1 member 12: 0:Unmodify 1:Untagged 2:Tagged 3:Nonmember |
| 1.3.6.1.4.1.4756.20.482.40.1.153 | Columnf1000EASX2FPort1Member13RemoteB | read-write | current | RemoteB device card port 1 member 13: 0:Unmodify 1:Untagged 2:Tagged 3:Nonmember |
| 1.3.6.1.4.1.4756.20.482.40.1.154 | Columnf1000EASX2FPort1Member14RemoteB | read-write | current | RemoteB device card port 1 member 14: 0:Unmodify 1:Untagged 2:Tagged 3:Nonmember |
| 1.3.6.1.4.1.4756.20.482.40.1.155 | Columnf1000EASX2FPort1Member15RemoteB | read-write | current | RemoteB device card port 1 member 15: 0:Unmodify 1:Untagged 2:Tagged 3:Nonmember |
| 1.3.6.1.4.1.4756.20.482.40.1.156 | Columnf1000EASX2FPort1Member16RemoteB | read-write | current | RemoteB device card port 1 member 16: 0:Unmodify 1:Untagged 2:Tagged 3:Nonmember |
| 1.3.6.1.4.1.4756.20.482.40.1.157 | Columnf1000EASX2FPort2Member1RemoteB | read-write | current | RemoteB device card port 2 member: 0:Unmodify 1:Untagged 2:Tagged 3:Nonmember |
| 1.3.6.1.4.1.4756.20.482.40.1.158 | Columnf1000EASX2FPort2Member2RemoteB | read-write | current | RemoteB device card port 2 member 2: 0:Unmodify 1:Untagged 2:Tagged 3:Nonmember |
| 1.3.6.1.4.1.4756.20.482.40.1.159 | Columnf1000EASX2FPort2Member3RemoteB | read-write | current | RemoteB device card port 2 member 3: 0:Unmodify 1:Untagged 2:Tagged 3:Nonmember |
| 1.3.6.1.4.1.4756.20.482.40.1.160 | Columnf1000EASX2FPort2Member4RemoteB | read-write | current | RemoteB device card port 2 member 4: 0:Unmodify 1:Untagged 2:Tagged 3:Nonmember |
| 1.3.6.1.4.1.4756.20.482.40.1.161 | Columnf1000EASX2FPort2Member5RemoteB | read-write | current | RemoteB device card port 2 member 5: 0:Unmodify 1:Untagged 2:Tagged 3:Nonmember |
| 1.3.6.1.4.1.4756.20.482.40.1.162 | Columnf1000EASX2FPort2Member6RemoteB | read-write | current | RemoteB device card port 2 member 6: 0:Unmodify 1:Untagged 2:Tagged 3:Nonmember |
| 1.3.6.1.4.1.4756.20.482.40.1.163 | Columnf1000EASX2FPort2Member7RemoteB | read-write | current | RemoteB device card port 2 member 7: 0:Unmodify 1:Untagged 2:Tagged 3:Nonmember |
| 1.3.6.1.4.1.4756.20.482.40.1.164 | Columnf1000EASX2FPort2Member8RemoteB | read-write | current | RemoteB device card port 2 member 8: 0:Unmodify 1:Untagged 2:Tagged 3:Nonmember |
| 1.3.6.1.4.1.4756.20.482.40.1.165 | Columnf1000EASX2FPort2Member9RemoteB | read-write | current | RemoteB device card port 2 member 9: 0:Unmodify 1:Untagged 2:Tagged 3:Nonmember |
| 1.3.6.1.4.1.4756.20.482.40.1.166 | Columnf1000EASX2FPort2Member10RemoteB | read-write | current | RemoteB device card port 2 member 10: 0:Unmodify 1:Untagged 2:Tagged 3:Nonmember |
| 1.3.6.1.4.1.4756.20.482.40.1.167 | Columnf1000EASX2FPort2Member11RemoteB | read-write | current | RemoteB device card port 2 member 11: 0:Unmodify 1:Untagged 2:Tagged 3:Nonmember |
| 1.3.6.1.4.1.4756.20.482.40.1.168 | Columnf1000EASX2FPort2Member12RemoteB | read-write | current | RemoteB device card port 2 member 12: 0:Unmodify 1:Untagged 2:Tagged 3:Nonmember |
| 1.3.6.1.4.1.4756.20.482.40.1.169 | Columnf1000EASX2FPort2Member13RemoteB | read-write | current | RemoteB device card port 2 member 13: 0:Unmodify 1:Untagged 2:Tagged 3:Nonmember |
| 1.3.6.1.4.1.4756.20.482.40.1.170 | Columnf1000EASX2FPort2Member14RemoteB | read-write | current | RemoteB device card port 2 member 14: 0:Unmodify 1:Untagged 2:Tagged 3:Nonmember |
| 1.3.6.1.4.1.4756.20.482.40.1.171 | Columnf1000EASX2FPort2Member15RemoteB | read-write | current | RemoteB device card port 2 member 15: 0:Unmodify 1:Untagged 2:Tagged 3:Nonmember |
| 1.3.6.1.4.1.4756.20.482.40.1.172 | Columnf1000EASX2FPort2Member16RemoteB | read-write | current | RemoteB device card port 2 member 16: 0:Unmodify 1:Untagged 2:Tagged 3:Nonmember |
| 1.3.6.1.4.1.4756.20.482.40.1.173 | Columnf1000EASX2FIpAddressRemoteB | read-write | current | RemoteB device IP address |
| 1.3.6.1.4.1.4756.20.482.40.1.174 | Columnf1000EASX2FNetMaskRemoteB | read-write | current | RemoteB device Netmask |
| 1.3.6.1.4.1.4756.20.482.40.1.175 | Columnf1000EASX2FGateWayRemoteB | read-write | current | RemoteB device Gateway |
| 1.3.6.1.4.1.4756.20.482.40.1.176 | Columnf1000EASX2FSetDefaultRemoteB | read-write | current | RemoteB device set to default |
| 1.3.6.1.4.1.4756.20.482.40.1.177 | Columnf1000EASX2FFx1LinkAlarmRemoteB | read-write | current | RemoteB device fiber 1 link alarm 0:Disable 1:Enable |
| 1.3.6.1.4.1.4756.20.482.40.1.178 | Columnf1000EASX2FFx2LinkAlarmRemoteB | read-write | current | RemoteB device fiber 2 link alarm 0:Disable 1:Enable |
| 1.3.6.1.4.1.4756.20.482.40.1.179 | Columnf1000EASX2FFHRModeRemoteB | read-write | current | RemoteB device card FHR Mode: 0:Disable 1:Enable |
| 1.3.6.1.4.1.4756.20.482.40.1.180 | Columnf1000EASX2FRemoteTLPTRemoteB | read-write | current | RemoteB device Remote TLPT mode : 0:Disalbe 1:Remote A 2:Remote B |
| 1.3.6.1.4.1.4756.20.490 | Nodef16G3RCards | |||
| 1.3.6.1.4.1.4756.20.490.20 | Tablef16G3RTable | not-accessible | current | A list of local FRM220-16G-3R card entries. The number of entries is f16G3R-No-L. |
| 1.3.6.1.4.1.4756.20.490.20.1 | Rowf16G3REntry | not-accessible | current | An entry containing management information applicable to a particular local FRM220-16G-3R card. |
| 1.3.6.1.4.1.4756.20.490.20.1.1 | Columnf16G3RChassisIndex | read-only | current | A unique value for each local card. It is the chassis location number. |
| 1.3.6.1.4.1.4756.20.490.20.1.2 | Columnf16G3RSlotIndex | read-only | current | A unique value for each local card. It is the slot location number. |
| 1.3.6.1.4.1.4756.20.490.20.1.3 | Columnf16G3RCardHWVer | read-only | current | Local FRM220-16G-3R card hardware version x.xxx |
| 1.3.6.1.4.1.4756.20.490.20.1.4 | Columnf16G3RCardFWVer | read-only | current | Local FRM220-16G-3R card firmware version x.xxx |
| 1.3.6.1.4.1.4756.20.490.20.1.5 | Columnf16G3RCardCPLDVer | read-only | current | Local FRM220-16G-3R card CPLD version x.xxx |
| 1.3.6.1.4.1.4756.20.490.20.1.6 | Columnf16G3RCardFPGAVer | read-only | current | Local FRM220-16G-3R card FPGA version x.xxx |
| 1.3.6.1.4.1.4756.20.490.20.1.7 | Columnf16G3RFx1Link | read-only | current | Local FRM220-16G-3R card Fiber1 link status: 0:Down 1:Up |
| 1.3.6.1.4.1.4756.20.490.20.1.8 | Columnf16G3RFx2Link | read-only | current | Local FRM220-16G-3R card Fiber2 link status: 0:Down 1:Up |
| 1.3.6.1.4.1.4756.20.490.20.1.9 | Columnf16G3RFx3Link | read-only | current | Local FRM220-16G-3R card Fiber3 link status: 0:Down 1:Up |
| 1.3.6.1.4.1.4756.20.490.20.1.10 | Columnf16G3RFx4Link | read-only | current | Local FRM220-16G-3R card Fiber4 link status: 0:Down 1:Up |
| 1.3.6.1.4.1.4756.20.490.20.1.11 | Columnf16G3RFx1CDRLocked | read-only | current | Local FRM220-16G-3R card Fiber1 CRD Locked: 0:Not Locked 1:Locked |
| 1.3.6.1.4.1.4756.20.490.20.1.12 | Columnf16G3RFx2CDRLocked | read-only | current | Local FRM220-16G-3R card Fiber2 CRD Locked: 0:Not Locked 1:Locked |
| 1.3.6.1.4.1.4756.20.490.20.1.13 | Columnf16G3RFx3CDRLocked | read-only | current | Local FRM220-16G-3R card Fiber3 CRD Locked: 0:Not Locked 1:Locked |
| 1.3.6.1.4.1.4756.20.490.20.1.14 | Columnf16G3RFx4CDRLocked | read-only | current | Local FRM220-16G-3R card Fiber4 CRD Locked: 0:Not Locked 1:Locked |
| 1.3.6.1.4.1.4756.20.490.20.1.15 | Columnf16G3RFx1TxFault | read-only | current | Local FRM220-16G-3R card Fiber1 Tx Fault: 0:Normal 1:Failure |
| 1.3.6.1.4.1.4756.20.490.20.1.16 | Columnf16G3RFx2TxFault | read-only | current | Local FRM220-16G-3R card Fiber2 Tx Fault: 0:Normal 1:Failure |
| 1.3.6.1.4.1.4756.20.490.20.1.17 | Columnf16G3RFx3TxFault | read-only | current | Local FRM220-16G-3R card Fiber3 Tx Fault: 0:Normal 1:Failure |
| 1.3.6.1.4.1.4756.20.490.20.1.18 | Columnf16G3RFx4TxFault | read-only | current | Local FRM220-16G-3R card Fiber4 Tx Fault: 0:Normal 1:Failure |
| 1.3.6.1.4.1.4756.20.490.20.1.19 | Columnf16G3RFx1DD | read-only | current | Local FRM220-16G-3R card fiber1 Digital Diagnostic function: 0:No 1:Yes |
| 1.3.6.1.4.1.4756.20.490.20.1.20 | Columnf16G3RFx2DD | read-only | current | Local FRM220-16G-3R card fiber2 Digital Diagnostic function: 0:No 1:Yes |
| 1.3.6.1.4.1.4756.20.490.20.1.21 | Columnf16G3RFx3DD | read-only | current | Local FRM220-16G-3R card fiber3 Digital Diagnostic function: 0:No 1:Yes |
| 1.3.6.1.4.1.4756.20.490.20.1.22 | Columnf16G3RFx4DD | read-only | current | Local FRM220-16G-3R card fiber4 Digital Diagnostic function: 0:No 1:Yes |
| 1.3.6.1.4.1.4756.20.490.20.1.23 | Columnf16G3RFx1DDStatus | read-only | current | Local FRM220-16G-3R card fiber1 D/D information: Status Support |
| 1.3.6.1.4.1.4756.20.490.20.1.24 | Columnf16G3RFx2DDStatus | read-only | current | Local FRM220-16G-3R card fiber2 D/D information: Status Support |
| 1.3.6.1.4.1.4756.20.490.20.1.25 | Columnf16G3RFx3DDStatus | read-only | current | Local FRM220-16G-3R card fiber3 D/D information: Status Support |
| 1.3.6.1.4.1.4756.20.490.20.1.26 | Columnf16G3RFx4DDStatus | read-only | current | Local FRM220-16G-3R card fiber4 D/D information: Status Support |
| 1.3.6.1.4.1.4756.20.490.20.1.27 | Columnf16G3RDeviceActive | read-write | current | Local FRM220-16G-3R card active: 0:Inactive 1:Active |
| 1.3.6.1.4.1.4756.20.490.20.1.28 | Columnf16G3RPortReset | read-write | current | Force local FRM220-16G-3R card to reset mode: 0:Off 1:Action |
| 1.3.6.1.4.1.4756.20.490.20.1.29 | Columnf16G3RSetDefault | read-write | current | Local FRM220-16G-3R card set to default : 0:Off 1:Action |
| 1.3.6.1.4.1.4756.20.490.20.1.30 | Columnf16G3RWorkMode | read-write | current | Local FRM220-16G-3R card Work Mode : 0:Protection 1:Dual Channel |
| 1.3.6.1.4.1.4756.20.490.20.1.31 | Columnf16G3RFx1Lbsetting | read-write | current | Local FRM220-16G-3R card Fiber1 Loopback: 0:Disable 1:Enable |
| 1.3.6.1.4.1.4756.20.490.20.1.32 | Columnf16G3RFx2Lbsetting | read-write | current | Local FRM220-16G-3R card Fiber2 Loopback: 0:Disable 1:Enable |
| 1.3.6.1.4.1.4756.20.490.20.1.33 | Columnf16G3RFx3Lbsetting | read-write | current | Local FRM220-16G-3R card Fiber3 Loopback: 0:Disable 1:Enable |
| 1.3.6.1.4.1.4756.20.490.20.1.34 | Columnf16G3RFx4Lbsetting | read-write | current | Local FRM220-16G-3R card Fiber4 Loopback: 0:Disable 1:Enable |
| 1.3.6.1.4.1.4756.20.490.20.1.35 | Columnf16G3RFx1LFPT | read-write | current | Local FRM220-16G-3R card Fiber1 Link Fault Pass Through: 0:Disable 1:Enable |
| 1.3.6.1.4.1.4756.20.490.20.1.36 | Columnf16G3RFx2LFPT | read-write | current | Local FRM220-16G-3R card Fiber2 Link Fault Pass Through: 0:Disable 1:Enable |
| 1.3.6.1.4.1.4756.20.490.20.1.37 | Columnf16G3RFx3LFPT | read-write | current | Local FRM220-16G-3R card Fiber3 Link Fault Pass Through: 0:Disable 1:Enable |
| 1.3.6.1.4.1.4756.20.490.20.1.38 | Columnf16G3RFx4LFPT | read-write | current | Local FRM220-16G-3R card Fiber4 Link Fault Pass Through: 0:Disable 1:Enable |
| 1.3.6.1.4.1.4756.20.490.20.1.39 | Columnf16G3RFx1ALSMode | read-write | current | Local FRM220-16G-3R card Fiber1 Auto Laser Showdown: 0:Disable 1:Enable |
| 1.3.6.1.4.1.4756.20.490.20.1.40 | Columnf16G3RFx2ALSMode | read-write | current | Local FRM220-16G-3R card Fiber2 Auto Laser Showdown: 0:Disable 1:Enable |
| 1.3.6.1.4.1.4756.20.490.20.1.41 | Columnf16G3RFx3ALSMode | read-write | current | Local FRM220-16G-3R card Fiber3 Auto Laser Showdown: 0:Disable 1:Enable |
| 1.3.6.1.4.1.4756.20.490.20.1.42 | Columnf16G3RFx4ALSMode | read-write | current | Local FRM220-16G-3R card Fiber4 Auto Laser Showdown: 0:Disable 1:Enable |
| 1.3.6.1.4.1.4756.20.490.20.1.43 | Columnf16G3RFx1LinkAlarm | read-write | current | Local FRM220-16G-3R card Fx1 Link Alarm: 0:Disalbe 1:Enable |
| 1.3.6.1.4.1.4756.20.490.20.1.44 | Columnf16G3RFx2LinkAlarm | read-write | current | Local FRM220-16G-3R card Fx2 Link Alarm: 0:Disalbe 1:Enable |
| 1.3.6.1.4.1.4756.20.490.20.1.45 | Columnf16G3RFx3LinkAlarm | read-write | current | Local FRM220-16G-3R card Fx3 Link Alarm: 0:Disalbe 1:Enable |
| 1.3.6.1.4.1.4756.20.490.20.1.46 | Columnf16G3RFx4LinkAlarm | read-write | current | Local FRM220-16G-3R card Fx4 Link Alarm: 0:Disalbe 1:Enable |
| 1.3.6.1.4.1.4756.20.490.20.1.47 | Columnf16G3RSemiActive | read-write | current | Local FRM220-16G-3R card Semi-Active (Protection mode only): 0:Disalbe 1:Enable |
| 1.3.6.1.4.1.4756.20.490.20.1.48 | Columnf16G3RWorkingPathStatus | read-only | current | Local FRM220-16G-3R card Workinng Path Status (Protection mode only): 0:Primary 1:Secondary |
| 1.3.6.1.4.1.4756.20.490.20.1.49 | Columnf16G3RWorkingPath | read-write | current | Local FRM220-16G-3R card Workinng Path(Protection mode only): 0:Auto-Revert 1:Non Revert 2:Primary 3:Secondary |
| 1.3.6.1.4.1.4756.20.490.20.1.50 | Columnf16G3RDataRatelStatus | read-only | current | Local FRM220-16G-3R card Data Rate 1 Status: |
| 1.3.6.1.4.1.4756.20.490.20.1.51 | Columnf16G3RDataRate2Status | read-only | current | Local FRM220-16G-3R card Data Rate 2 Status(Dual Channel mode only): |
| 1.3.6.1.4.1.4756.20.490.20.1.52 | Columnf16G3RProtocol1 | read-only | current | Local FRM220-16G-3R card Protocol 1: 0:Ethernet 1:SONET/SDH 2:Fiber Channel 3:CPRI 4:OBSAI 5:OTU 6:ODU |
| 1.3.6.1.4.1.4756.20.490.20.1.53 | Columnf16G3RRate1 | read-write | current | Local FRM220-16G-3R card Rate 1: Ethernet 0: 10GE 1: 1GE 2: 2500Base-X SONET/SDH 8: OC-192/STM-64 9: OC-48/STM-16 10:OC-24 11:OC-12/STM-4 Fiber Channel 16: 16G… |
| 1.3.6.1.4.1.4756.20.490.20.1.54 | Columnf16G3RProtocol2 | read-only | current | Local FRM220-16G-3R Protocol 2 (Dual Channel only): 0:Ethernet 1:SONET/SDH 2:Fiber Channel 3:CPRI 4:OBSAI 5:OTU 6:ODU |
| 1.3.6.1.4.1.4756.20.490.20.1.55 | Columnf16G3RRate2 | read-write | current | Local FRM220-16G-3R card Rate2(Dual Channel only): Ethernet 0: 10GE 1: 1GE 2: 2500Base-X SONET/SDH 8: OC-192/STM-64 9: OC-48/STM-16 10:OC-24 11:OC-12/STM-4 Fib… |
| 1.3.6.1.4.1.4756.20.490.20.1.56 | Columnf16G3RChannel1Active | read-write | current | Local FRM220-16G-3R card Channel 1 Active(Dual Channel only): 0:Disable 1:Enable |
| 1.3.6.1.4.1.4756.20.490.20.1.57 | Columnf16G3RChannel2Active | read-write | current | Local FRM220-16G-3R card Channel 2 Active(Dual Channel only): 0:Disable 1:Enable |
| 1.3.6.1.4.1.4756.20.490.20.1.58 | Columnf16G3RFx1DDVendor | read-only | current | Local FRM220-16G-3R card fiber1 D/D information: Vendor name |
| 1.3.6.1.4.1.4756.20.490.20.1.59 | Columnf16G3RFx1DDPartNo | read-only | current | Local FRM220-16G-3R card fiber1 D/D information: Vendor part number |
| 1.3.6.1.4.1.4756.20.490.20.1.60 | Columnf16G3RFx1DDVendorSN | read-only | current | Local FRM220-16G-3R card fiber1 D/D information: Vendor Serial number |
| 1.3.6.1.4.1.4756.20.490.20.1.61 | Columnf16G3RFx1DDFiberType | read-only | current | Local FRM220-16G-3R card fiber1 D/D information: Fiber Type |
| 1.3.6.1.4.1.4756.20.490.20.1.62 | Columnf16G3RFx1DDWaveLen | read-only | current | Local FRM220-16G-3R card fiber1 D/D information: Wave length |
| 1.3.6.1.4.1.4756.20.490.20.1.63 | Columnf16G3RFx1DDWaveLen2 | read-only | current | Local FRM220-16G-3R card fiber1 D/D information: Wave length 2 |
| 1.3.6.1.4.1.4756.20.490.20.1.64 | Columnf16G3RFx1DDLinkLen | read-only | current | Local FRM220-16G-3R card fiber1 D/D information: Link length |
| 1.3.6.1.4.1.4756.20.490.20.1.65 | Columnf16G3RFx1DDLenUnit | read-only | current | Local FRM220-16G-3R card fiber1 D/D information: Length Unit |
| 1.3.6.1.4.1.4756.20.490.20.1.66 | Columnf16G3RFx1DDRxSens | read-only | current | Local FRM220-16G-3R card fiber1 D/D information: Rx Sensitivity |
| 1.3.6.1.4.1.4756.20.490.20.1.67 | Columnf16G3RFx1DDTxPWR | read-only | current | Local FRM220-16G-3R card fiber1 D/D information: Tx power |
| 1.3.6.1.4.1.4756.20.490.20.1.68 | Columnf16G3RFx1DDRxPWR | read-only | current | Local FRM220-16G-3R card fiber1 D/D information: Rx power |
| 1.3.6.1.4.1.4756.20.490.20.1.69 | Columnf16G3RFx1RxPowerStatus | read-only | current | Local FRM220-16G-3R card fiber1 Rx Power Status: 0:Normal 1:Warning 2:Alarm |
| 1.3.6.1.4.1.4756.20.490.20.1.70 | Columnf16G3RFx1DDTemp | read-only | current | Local FRM220-16G-3R card fiber1 D/D information: Temperature in degree C |
| 1.3.6.1.4.1.4756.20.490.20.1.71 | Columnf16G3RFx1DDPWRMargin | read-only | current | Local FRM220-16G-3R card fiber1 D/D information: Power margin |
| 1.3.6.1.4.1.4756.20.490.20.1.72 | Columnf16G3RFx2DDVendor | read-only | current | Local FRM220-16G-3R card fiber2 D/D information: Vendor name |
| 1.3.6.1.4.1.4756.20.490.20.1.73 | Columnf16G3RFx2DDPartNo | read-only | current | Local FRM220-16G-3R card fiber2 D/D information: Vendor part number |
| 1.3.6.1.4.1.4756.20.490.20.1.74 | Columnf16G3RFx2DDVendorSN | read-only | current | Local FRM220-16G-3R card fiber2 D/D information: Vendor Serial number |
| 1.3.6.1.4.1.4756.20.490.20.1.75 | Columnf16G3RFx2DDFiberType | read-only | current | Local FRM220-16G-3R card fiber2 D/D information: Fiber Type |
| 1.3.6.1.4.1.4756.20.490.20.1.76 | Columnf16G3RFx2DDWaveLen | read-only | current | Local FRM220-16G-3R card fiber2 D/D information: Wave length |
| 1.3.6.1.4.1.4756.20.490.20.1.77 | Columnf16G3RFx2DDWaveLen2 | read-only | current | Local FRM220-16G-3R card fiber2 D/D information: Wave length 2 |
| 1.3.6.1.4.1.4756.20.490.20.1.78 | Columnf16G3RFx2DDLinkLen | read-only | current | Local FRM220-16G-3R card fiber2 D/D information: Link length |
| 1.3.6.1.4.1.4756.20.490.20.1.79 | Columnf16G3RFx2DDLenUnit | read-only | current | Local FRM220-16G-3R card fiber2 D/D information: Length Unit |
| 1.3.6.1.4.1.4756.20.490.20.1.80 | Columnf16G3RFx2DDRxSens | read-only | current | Local FRM220-16G-3R card fiber2 D/D information: Rx Sensitivity |
| 1.3.6.1.4.1.4756.20.490.20.1.81 | Columnf16G3RFx2DDTxPWR | read-only | current | Local FRM220-16G-3R card fiber2 D/D information: Tx power |
| 1.3.6.1.4.1.4756.20.490.20.1.82 | Columnf16G3RFx2DDRxPWR | read-only | current | Local FRM220-16G-3R card fiber2 D/D information: Rx power |
| 1.3.6.1.4.1.4756.20.490.20.1.83 | Columnf16G3RFx2RxPowerStatus | read-only | current | Local FRM220-16G-3R card fiber2 Rx Power Status: 0:Normal 1:Warning 2:Alarm |
| 1.3.6.1.4.1.4756.20.490.20.1.84 | Columnf16G3RFx2DDTemp | read-only | current | Local FRM220-16G-3R card fiber2 D/D information: Temperature in degree C |
| 1.3.6.1.4.1.4756.20.490.20.1.85 | Columnf16G3RFx2DDPWRMargin | read-only | current | Local FRM220-16G-3R card fiber2 D/D information: Power margin |
| 1.3.6.1.4.1.4756.20.490.20.1.86 | Columnf16G3RFx3DDVendor | read-only | current | Local FRM220-16G-3R card fiber3 D/D information: Vendor name |
| 1.3.6.1.4.1.4756.20.490.20.1.87 | Columnf16G3RFx3DDPartNo | read-only | current | Local FRM220-16G-3R card fiber3 D/D information: Vendor part number |
| 1.3.6.1.4.1.4756.20.490.20.1.88 | Columnf16G3RFx3DDVendorSN | read-only | current | Local FRM220-16G-3R card fiber3 D/D information: Vendor Serial number |
| 1.3.6.1.4.1.4756.20.490.20.1.89 | Columnf16G3RFx3DDFiberType | read-only | current | Local FRM220-16G-3R card fiber3 D/D information: Fiber Type |
| 1.3.6.1.4.1.4756.20.490.20.1.90 | Columnf16G3RFx3DDWaveLen | read-only | current | Local FRM220-16G-3R card fiber3 D/D information: Wave length |
| 1.3.6.1.4.1.4756.20.490.20.1.91 | Columnf16G3RFx3DDWaveLen2 | read-only | current | Local FRM220-16G-3R card fiber3 D/D information: Wave length 2 |
| 1.3.6.1.4.1.4756.20.490.20.1.92 | Columnf16G3RFx3DDLinkLen | read-only | current | Local FRM220-16G-3R card fiber3 D/D information: Link length |
| 1.3.6.1.4.1.4756.20.490.20.1.93 | Columnf16G3RFx3DDLenUnit | read-only | current | Local FRM220-16G-3R card fiber3 D/D information: Length Unit |
| 1.3.6.1.4.1.4756.20.490.20.1.94 | Columnf16G3RFx3DDRxSens | read-only | current | Local FRM220-16G-3R card fiber3 D/D information: Rx Sensitivity |
| 1.3.6.1.4.1.4756.20.490.20.1.95 | Columnf16G3RFx3DDTxPWR | read-only | current | Local FRM220-16G-3R card fiber3 D/D information: Tx power |
| 1.3.6.1.4.1.4756.20.490.20.1.96 | Columnf16G3RFx3DDRxPWR | read-only | current | Local FRM220-16G-3R card fiber3 D/D information: Rx power |
| 1.3.6.1.4.1.4756.20.490.20.1.97 | Columnf16G3RFx3RxPowerStatus | read-only | current | Local FRM220-16G-3R card fiber3 Rx Power Status: 0:Normal 1:Warning 2:Alarm |
| 1.3.6.1.4.1.4756.20.490.20.1.98 | Columnf16G3RFx3DDTemp | read-only | current | Local FRM220-16G-3R card fiber3 D/D information: Temperature in degree C |
| 1.3.6.1.4.1.4756.20.490.20.1.99 | Columnf16G3RFx3DDPWRMargin | read-only | current | Local FRM220-16G-3R card fiber3 D/D information: Power margin |
| 1.3.6.1.4.1.4756.20.490.20.1.100 | Columnf16G3RFx4DDVendor | read-only | current | Local FRM220-16G-3R card fiber4 D/D information: Vendor name |
| 1.3.6.1.4.1.4756.20.490.20.1.101 | Columnf16G3RFx4DDPartNo | read-only | current | Local FRM220-16G-3R card fiber4 D/D information: Vendor part number |
| 1.3.6.1.4.1.4756.20.490.20.1.102 | Columnf16G3RFx4DDVendorSN | read-only | current | Local FRM220-16G-3R card fiber4 D/D information: Vendor Serial number |
| 1.3.6.1.4.1.4756.20.490.20.1.103 | Columnf16G3RFx4DDFiberType | read-only | current | Local FRM220-16G-3R card fiber4 D/D information: Fiber Type |
| 1.3.6.1.4.1.4756.20.490.20.1.104 | Columnf16G3RFx4DDWaveLen | read-only | current | Local FRM220-16G-3R card fiber4 D/D information: Wave length |
| 1.3.6.1.4.1.4756.20.490.20.1.105 | Columnf16G3RFx4DDWaveLen2 | read-only | current | Local FRM220-16G-3R card fiber4 D/D information: Wave length 2 |
| 1.3.6.1.4.1.4756.20.490.20.1.106 | Columnf16G3RFx4DDLinkLen | read-only | current | Local FRM220-16G-3R card fiber4 D/D information: Link length |
| 1.3.6.1.4.1.4756.20.490.20.1.107 | Columnf16G3RFx4DDLenUnit | read-only | current | Local FRM220-16G-3R card fiber4 D/D information: Length Unit |
| 1.3.6.1.4.1.4756.20.490.20.1.108 | Columnf16G3RFx4DDRxSens | read-only | current | Local FRM220-16G-3R card fiber4 D/D information: Rx Sensitivity |
| 1.3.6.1.4.1.4756.20.490.20.1.109 | Columnf16G3RFx4DDTxPWR | read-only | current | Local FRM220-16G-3R card fiber4 D/D information: Tx power |
| 1.3.6.1.4.1.4756.20.490.20.1.110 | Columnf16G3RFx4DDRxPWR | read-only | current | Local FRM220-16G-3R card fiber4 D/D information: Rx power |
| 1.3.6.1.4.1.4756.20.490.20.1.111 | Columnf16G3RFx4RxPowerStatus | read-only | current | Local FRM220-16G-3R card fiber4 Rx Power Status: 0:Normal 1:Warning 2:Alarm |
| 1.3.6.1.4.1.4756.20.490.20.1.112 | Columnf16G3RFx4DDTemp | read-only | current | Local FRM220-16G-3R card fiber4 D/D information: Temperature in degree C |
| 1.3.6.1.4.1.4756.20.490.20.1.113 | Columnf16G3RFx4DDPWRMargin | read-only | current | Local FRM220-16G-3R card fiber4 D/D information: Power margin |
| 1.3.6.1.4.1.4756.20.490.20.1.114 | Columnf16G3RFx1RxPowerStatusAlarm | read-write | current | Local FRM220-16G-3R card Line Rx Power Status trap. 0:Disable 1:Enable |
| 1.3.6.1.4.1.4756.20.490.20.1.115 | Columnf16G3RFx1LosAssertAlarm | read-write | current | Local FRM220-16G-3R card Line LOS Assert trap. 0:Disable 1:Enable |
| 1.3.6.1.4.1.4756.20.490.20.1.116 | Columnf16G3RFx1RxPowerWarningThreshold | read-write | current | Set Line Rx Power Warning Threshold: Input range is from -60 to +10. |
| 1.3.6.1.4.1.4756.20.490.20.1.117 | Columnf16G3RFx1RxPowerAlarmThreshold | read-write | current | Set Line Rx Power Alarm Threshold: Input range is from -60 to +10. |
| 1.3.6.1.4.1.4756.20.490.20.1.118 | Columnf16G3RFx2RxPowerStatusAlarm | read-write | current | Local FRM220-16G-3R card Primary Rx Power Status trap. 0:Disable 1:Enable |
| 1.3.6.1.4.1.4756.20.490.20.1.119 | Columnf16G3RFx2LosAssertAlarm | read-write | current | Local FRM220-16G-3R card Primary LOS Assert trap. 0:Disable 1:Enable |
| 1.3.6.1.4.1.4756.20.490.20.1.120 | Columnf16G3RFx2RxPowerWarningThreshold | read-write | current | Set Primary Rx Power Warning Threshold: Input range is from -60 to +10. |
| 1.3.6.1.4.1.4756.20.490.20.1.121 | Columnf16G3RFx2RxPowerAlarmThreshold | read-write | current | Set Primary Rx Power Alarm Threshold: Input range is from -60 to +10. |
| 1.3.6.1.4.1.4756.20.490.20.1.122 | Columnf16G3RFx3RxPowerStatusAlarm | read-write | current | Local FRM220-16G-3R card Secondary Rx Power Status trap. 0:Disable 1:Enable |
| 1.3.6.1.4.1.4756.20.490.20.1.123 | Columnf16G3RFx3LosAssertAlarm | read-write | current | Local FRM220-16G-3R card Secondary LOS Assert trap. 0:Disable 1:Enable |
| 1.3.6.1.4.1.4756.20.490.20.1.124 | Columnf16G3RFx3RxPowerWarningThreshold | read-write | current | Set Secondary Rx Power Warning Threshold: Input range is from -60 to +10. |
| 1.3.6.1.4.1.4756.20.490.20.1.125 | Columnf16G3RFx3RxPowerAlarmThreshold | read-write | current | Set Secondary Rx Power Alarm Threshold: Input range is from -60 to +10. |
| 1.3.6.1.4.1.4756.20.490.20.1.126 | Columnf16G3RFx4RxPowerStatusAlarm | read-write | current | Local FRM220-16G-3R card Fx4 Rx Power Status trap. 0:Disable 1:Enable |
| 1.3.6.1.4.1.4756.20.490.20.1.127 | Columnf16G3RFx4LosAssertAlarm | read-write | current | Local FRM220-16G-3R card Fx4 LOS Assert trap. 0:Disable 1:Enable |
| 1.3.6.1.4.1.4756.20.490.20.1.128 | Columnf16G3RFx4RxPowerWarningThreshold | read-write | current | Set Secondary Rx Power Warning Threshold: Input range is from -60 to +10. |
| 1.3.6.1.4.1.4756.20.490.20.1.129 | Columnf16G3RFx4RxPowerAlarmThreshold | read-write | current | Set Secondary Rx Power Alarm Threshold: Input range is from -60 to +10. |
| 1.3.6.1.4.1.4756.20.490.20.1.130 | Columnf16G3RTemperature | read-only | current | Local FRM220-16G-3R card temperature information: Temperature in degree C |
| 1.3.6.1.4.1.4756.20.490.20.1.131 | Columnf16G3RPowerLed | read-only | current | Local FRM220-16G-3R card Powe Led. 0:ON (Power ON) 1:Flash (Standby; 1s ON/1s OFF) |
| 1.3.6.1.4.1.4756.20.490.20.1.132 | Columnf16G3RSystemLed | read-only | current | Local FRM220-16G-3R card Syetem Led. 0:OFF(Fail) 1:ON (Normal) |
| 1.3.6.1.4.1.4756.20.490.20.1.133 | Columnf16G3RModeLed | read-only | current | Local FRM220-16G-3R card Mode Led. 0:OFF(Dual Channel) 1:ON (Protection) |
| 1.3.6.1.4.1.4756.20.490.20.1.134 | Columnf16G3RTestLed | read-only | current | Local FRM220-16G-3R card Test Led. 0:OFF(Normal) 1:ON (Test; Loopback Test) |
| 1.3.6.1.4.1.4756.20.490.20.1.135 | Columnf16G3RFx1Led | read-only | current | Local FRM220-16G-3R card Fx1 Led. 0:OFF(Link Down) 1:ON (SYNC) 2:LB (0.1s ON/0.1s OFF) 3:Link Up (0.5s ON/0.5s OFF) |
| 1.3.6.1.4.1.4756.20.490.20.1.136 | Columnf16G3RFx2Led | read-only | current | Local FRM220-16G-3R card Fx2 Led. 0:OFF(Link Down) 1:ON (SYNC) 2:LB (0.1s ON/0.1s OFF) 3:Link Up (0.5s ON/0.5s OFF) 4:Working Path (3s ON/0.2s OFF) |
| 1.3.6.1.4.1.4756.20.490.20.1.137 | Columnf16G3RFx3Led | read-only | current | Local FRM220-16G-3R card Fx3 Led. 0:OFF(Link Down) 1:ON (SYNC) 2:LB (0.1s ON/0.1s OFF) 3:Link Up (0.5s ON/0.5s OFF) 4:Working Path (3s ON/0.2s OFF) |
| 1.3.6.1.4.1.4756.20.490.20.1.138 | Columnf16G3RFx4Led | read-only | current | Local FRM220-16G-3R card Fx4 Led. 0:OFF(Link Down) 1:ON (SYNC) 2:LB (0.1s ON/0.1s OFF) 3:Link Up (0.5s ON/0.5s OFF) |
| 1.3.6.1.4.1.4756.20.500 | NodenidLocalCards | |||
| 1.3.6.1.4.1.4756.20.500.20 | TablenidLocalTable | not-accessible | current | A list of local FRM220-MSW404/MSW404S card entries. The number of entries is f16G3R-No-L. |
| 1.3.6.1.4.1.4756.20.500.20.1 | RownidLocalEntry | not-accessible | current | An entry containing management information applicable to a particular local FRM220-MSW404/MSW404S card. |
| 1.3.6.1.4.1.4756.20.500.20.1.1 | ColumnnidChassisIndexLocal | read-only | current | A unique value for each local card. It is the chassis location number. |
| 1.3.6.1.4.1.4756.20.500.20.1.2 | ColumnnidSlotIndexLocal | read-only | current | A unique value for each local card. It is the slot location number. |
| 1.3.6.1.4.1.4756.20.500.20.1.3 | ColumnnidCardHWVerLocal | read-only | current | Local NID card hardware version x.xxx |
| 1.3.6.1.4.1.4756.20.500.20.1.4 | ColumnnidCardFWVerLocal | read-only | current | Local NID card firmware version x.xxx |
| 1.3.6.1.4.1.4756.20.500.20.1.5 | ColumnnidCardCPLDVerLocal | read-only | current | Local NID card CPLD version x.xxx |
| 1.3.6.1.4.1.4756.20.500.20.1.6 | ColumnnidCardFPGAVerLocal | read-only | current | Local NID card FPGA version x.xxx |
| 1.3.6.1.4.1.4756.20.500.20.1.7 | ColumnnidModelLocal | read-only | current | Card Type: 0:MSW404 1:MSW404S |
| 1.3.6.1.4.1.4756.20.500.20.1.8 | ColumnnidDNSServerTypeLocal | read-write | current | NID Series card IP Configuration: This setting controls the DNS name resolution done by the switch. The following modes are supported: 1:From any DHCP interfac… |
| 1.3.6.1.4.1.4756.20.500.20.1.9 | ColumnnidDNSServerSettingLocal | read-write | current | NID Series card IP Configuration: If iDNSServerType setting '3:Configured',this value must setting IP address format as below: Dotted Decimal Notation refers t… |
| 1.3.6.1.4.1.4756.20.500.20.1.10 | ColumnnidDNSproxyLocal | read-write | current | NID Series card IP Configuration: When DNS proxy is enabled, system will relay DNS requests to the currently configured DNS server, and reply as a DNS resolver… |
| 1.3.6.1.4.1.4756.20.500.20.1.11 | ColumnnidAddIPV4InterfaceLocal | read-write | current | NID Series card IP Interfaces: Add a new IP VLAN Interface: Syntax: [<Interface>] [<vlan_list>] [<IPV4_Addr>] [<IPV4_MASK>] Interface : 1~4 |
| 1.3.6.1.4.1.4756.20.500.20.1.12 | ColumnnidDeleteInterfaceLocal | read-write | current | NID Series card IP Interfaces: Delete a IPv4/v6 VLAN Interface: Syntax: [<Interface>] Interface: 1~4 |
| 1.3.6.1.4.1.4756.20.500.20.1.13 | ColumnnidIPInterface1VLANLocal | read-only | current | NID Series card IP Interfaces: The VLAN associated with the IP interface. Only ports in this VLAN will be able to access the IP interface. This field is only a… |
| 1.3.6.1.4.1.4756.20.500.20.1.14 | ColumnnidIPInterface1DHCPLocal | read-write | current | NID Series card IP Interfaces: DHCP |
| 1.3.6.1.4.1.4756.20.500.20.1.15 | ColumnnidIPInterface1FallbackLocal | read-write | current | NID Series card IP Interfaces: Fallback |
| 1.3.6.1.4.1.4756.20.500.20.1.16 | ColumnnidIPInterface1IPV4AddressLocal | read-only | current | NID Series card IP Interfaces: IPV4 Address |
| 1.3.6.1.4.1.4756.20.500.20.1.17 | ColumnnidIPInterface1IPV4MASKLenLocal | read-only | current | NID Series card IP Interfaces: IPV4 MASK Length |
| 1.3.6.1.4.1.4756.20.500.20.1.18 | ColumnnidIPInterface2VLANLocal | read-only | current | NID Series card IP Interfaces: The VLAN associated with the IP interface. Only ports in this VLAN will be able to access the IP interface. This field is only a… |
| 1.3.6.1.4.1.4756.20.500.20.1.19 | ColumnnidIPInterface2DHCPLocal | read-write | current | NID Series card IP Interfaces: DHCP |
| 1.3.6.1.4.1.4756.20.500.20.1.20 | ColumnnidIPInterface2FallbackLocal | read-write | current | NID Series card IP Interfaces: Fallback |
| 1.3.6.1.4.1.4756.20.500.20.1.21 | ColumnnidIPInterface2IPV4AddressLocal | read-only | current | NID Series card IP Interfaces: IPV4 Address |
| 1.3.6.1.4.1.4756.20.500.20.1.22 | ColumnnidIPInterface2IPV4MASKLenLocal | read-only | current | NID Series card IP Interfaces: IPV4 MASK Length |
| 1.3.6.1.4.1.4756.20.500.20.1.23 | ColumnnidIPInterface3VLANLocal | read-only | current | NID Series card IP Interfaces: The VLAN associated with the IP interface. Only ports in this VLAN will be able to access the IP interface. This field is only a… |
| 1.3.6.1.4.1.4756.20.500.20.1.24 | ColumnnidIPInterface3DHCPLocal | read-write | current | NID Series card IP Interfaces: DHCP |
| 1.3.6.1.4.1.4756.20.500.20.1.25 | ColumnnidIPInterface3FallbackLocal | read-write | current | NID Series card IP Interfaces: Fallback |
| 1.3.6.1.4.1.4756.20.500.20.1.26 | ColumnnidIPInterface3IPV4AddressLocal | read-only | current | NID Series card IP Interfaces: IPV4 Address |
| 1.3.6.1.4.1.4756.20.500.20.1.27 | ColumnnidIPInterface3IPV4MASKLenLocal | read-only | current | NID Series card IP Interfaces: IPV4 MASK Length |
| 1.3.6.1.4.1.4756.20.500.20.1.28 | ColumnnidIPInterface4VLANLocal | read-only | current | NID Series card IP Interfaces: The VLAN associated with the IP interface. Only ports in this VLAN will be able to access the IP interface. This field is only a… |
| 1.3.6.1.4.1.4756.20.500.20.1.29 | ColumnnidIPInterface4DHCPLocal | read-write | current | NID Series card IP Interfaces: DHCP |
| 1.3.6.1.4.1.4756.20.500.20.1.30 | ColumnnidIPInterface4FallbackLocal | read-write | current | NID Series card IP Interfaces: Fallback |
| 1.3.6.1.4.1.4756.20.500.20.1.31 | ColumnnidIPInterface4IPV4AddressLocal | read-only | current | NID Series card IP Interfaces: IPV4 Address |
| 1.3.6.1.4.1.4756.20.500.20.1.32 | ColumnnidIPInterface4IPV4MASKLenLocal | read-only | current | NID Series card IP Interfaces: IPV4 MASK Length |
| 1.3.6.1.4.1.4756.20.500.20.1.33 | ColumnnidAddIPV6InterfaceLocal | read-write | current | NID Series card IP Interfaces: Add a new IPv6 VLAN Interface: Syntax: [<Interface>] [<vlan_list>] [<IPV4_Addr>] [<IPV4_MASK>] Interface : 1~4 |
| 1.3.6.1.4.1.4756.20.500.20.1.34 | ColumnnidIPInterface1IPV6AddressLocal | read-only | current | NID Series card IP Interfaces: IPV6 Address |
| 1.3.6.1.4.1.4756.20.500.20.1.35 | ColumnnidIPInterface1IPV6MASKLenLocal | read-only | current | NID Series card IP Interfaces: IPV6 MASK Length |
| 1.3.6.1.4.1.4756.20.500.20.1.36 | ColumnnidIPInterface2IPV6AddressLocal | read-only | current | NID Series card IP Interfaces: IPV6 Address |
| 1.3.6.1.4.1.4756.20.500.20.1.37 | ColumnnidIPInterface2IPV6MASKLenLocal | read-only | current | NID Series card IP Interfaces: IPV6 MASK Length |
| 1.3.6.1.4.1.4756.20.500.20.1.38 | ColumnnidIPInterface3IPV6AddressLocal | read-only | current | NID Series card IP Interfaces: IPV6 Address |
| 1.3.6.1.4.1.4756.20.500.20.1.39 | ColumnnidIPInterface3IPV6MASKLenLocal | read-only | current | NID Series card IP Interfaces: IPV6 MASK Length |
| 1.3.6.1.4.1.4756.20.500.20.1.40 | ColumnnidIPInterface4IPV6AddressLocal | read-only | current | NID Series card IP Interfaces: IPV6 Address |
| 1.3.6.1.4.1.4756.20.500.20.1.41 | ColumnnidIPInterface4IPV6MASKLenLocal | read-only | current | NID Series card IP Interfaces: IPV6 MASK Length |
| 1.3.6.1.4.1.4756.20.500.20.1.42 | ColumnnidPort1LinkstsLocal | read-only | current | NID Series card Port1 link status: 0:Link down 1:Link up |
| 1.3.6.1.4.1.4756.20.500.20.1.43 | ColumnnidPort1SpeedstsLocal | read-only | current | NID Series card Port1 speed status 10Base-T 100Base-Tx 1000Base-Tx 2.5G |
| 1.3.6.1.4.1.4756.20.500.20.1.44 | ColumnnidPort1DuplexstsLocal | read-only | current | NID Series card Port1 duplex status 0: Half 1: Full |
| 1.3.6.1.4.1.4756.20.500.20.1.45 | ColumnnidPort1RxPausestsLocal | read-only | current | NID Series card Port1 rx pause status 0: No 1: Yes |
| 1.3.6.1.4.1.4756.20.500.20.1.46 | ColumnnidPort1TxPausestsLocal | read-only | current | NID Series card Port1 tx pause status 0: No 1: Yes |
| 1.3.6.1.4.1.4756.20.500.20.1.47 | ColumnnidPort2LinkstsLocal | read-only | current | NID Series card Port2 link status: 0:Link down 1:Link up |
| 1.3.6.1.4.1.4756.20.500.20.1.48 | ColumnnidPort2SpeedstsLocal | read-only | current | NID Series card Port2 speed status 10Base-T 100Base-Tx 1000Base-Tx 2.5G |
| 1.3.6.1.4.1.4756.20.500.20.1.49 | ColumnnidPort2DuplexstsLocal | read-only | current | NID Series card Port2 duplex status 0: Half 1: Full |
| 1.3.6.1.4.1.4756.20.500.20.1.50 | ColumnnidPort2RxPausestsLocal | read-only | current | NID Series card Port2 rx pause status 0: No 1: Yes |
| 1.3.6.1.4.1.4756.20.500.20.1.51 | ColumnnidPort2TxPausestsLocal | read-only | current | NID Series card Port2 tx pause status 0: No 1: Yes |
| 1.3.6.1.4.1.4756.20.500.20.1.52 | ColumnnidPort3LinkstsLocal | read-only | current | NID Series card Port3 link status: 0:Link down 1:Link up |
| 1.3.6.1.4.1.4756.20.500.20.1.53 | ColumnnidPort3SpeedstsLocal | read-only | current | NID Series card Port3 speed status 10Base-T 100Base-Tx 1000Base-Tx |
| 1.3.6.1.4.1.4756.20.500.20.1.54 | ColumnnidPort3DuplexstsLocal | read-only | current | NID Series card Port3 duplex status 0: Half 1: Full |
| 1.3.6.1.4.1.4756.20.500.20.1.55 | ColumnnidPort3RxPausestsLocal | read-only | current | NID Series card Port3 rx pause status 0: No 1: Yes |
| 1.3.6.1.4.1.4756.20.500.20.1.56 | ColumnnidPort3TxPausestsLocal | read-only | current | NID Series card Port3 tx pause status 0: No 1: Yes |
| 1.3.6.1.4.1.4756.20.500.20.1.57 | ColumnnidPort4LinkstsLocal | read-only | current | NID Series card Port4 link status: 0:Link down 1:Link up |
| 1.3.6.1.4.1.4756.20.500.20.1.58 | ColumnnidPort4SpeedstsLocal | read-only | current | NID Series card Port4 speed status 10Base-T 100Base-Tx 1000Base-Tx |
| 1.3.6.1.4.1.4756.20.500.20.1.59 | ColumnnidPort4DuplexstsLocal | read-only | current | NID Series card Port4 duplex status 0: Half 1: Full |
| 1.3.6.1.4.1.4756.20.500.20.1.60 | ColumnnidPort4RxPausestsLocal | read-only | current | NID Series card Port4 rx pause status 0: No 1: Yes |
| 1.3.6.1.4.1.4756.20.500.20.1.61 | ColumnnidPort4TxPausestsLocal | read-only | current | NID Series card Port4 tx pause status 0: No 1: Yes |
| 1.3.6.1.4.1.4756.20.500.20.1.62 | ColumnnidPort5LinkstsLocal | read-only | current | NID Series card Port5 link status: 0:Link down 1:Link up |
| 1.3.6.1.4.1.4756.20.500.20.1.63 | ColumnnidPort5SpeedstsLocal | read-only | current | NID Series card Port5 speed status 10Base-T 100Base-Tx 1000Base-Tx |
| 1.3.6.1.4.1.4756.20.500.20.1.64 | ColumnnidPort5DuplexstsLocal | read-only | current | NID Series card Port5 duplex status 0: Half 1: Full |
| 1.3.6.1.4.1.4756.20.500.20.1.65 | ColumnnidPort5RxPausestsLocal | read-only | current | NID Series card Port5 rx pause status 0: No 1: Yes |
| 1.3.6.1.4.1.4756.20.500.20.1.66 | ColumnnidPort5TxPausestsLocal | read-only | current | NID Series card Port5 tx pause status 0: No 1: Yes |
| 1.3.6.1.4.1.4756.20.500.20.1.67 | ColumnnidPort6LinkstsLocal | read-only | current | NID Series card Port6 link status: 0:Link down 1:Link up |
| 1.3.6.1.4.1.4756.20.500.20.1.68 | ColumnnidPort6SpeedstsLocal | read-only | current | NID Series card Port6 speed status 10Base-T 100Base-Tx 1000Base-Tx |
| 1.3.6.1.4.1.4756.20.500.20.1.69 | ColumnnidPort6DuplexstsLocal | read-only | current | NID Series card Port6 duplex status 0: Half 1: Full |
| 1.3.6.1.4.1.4756.20.500.20.1.70 | ColumnnidPort6RxPausestsLocal | read-only | current | NID Series card Port6 rx pause status 0: No 1: Yes |
| 1.3.6.1.4.1.4756.20.500.20.1.71 | ColumnnidPort6TxPausestsLocal | read-only | current | NID Series card Port6 tx pause status 0: No 1: Yes |
| 1.3.6.1.4.1.4756.20.500.20.1.72 | ColumnnidPort7LinkstsLocal | read-only | current | NID Series card Port7 link status: 0:Link down 1:Link up |
| 1.3.6.1.4.1.4756.20.500.20.1.73 | ColumnnidPort7SpeedstsLocal | read-only | current | NID Series card Port7 speed status 10Base-T 100Base-Tx 1000Base-Tx |
| 1.3.6.1.4.1.4756.20.500.20.1.74 | ColumnnidPort7DuplexstsLocal | read-only | current | NID Series card Port7 duplex status 0: Half 1: Full |
| 1.3.6.1.4.1.4756.20.500.20.1.75 | ColumnnidPort7RxPausestsLocal | read-only | current | NID Series card Port7 rx pause status 0: No 1: Yes |
| 1.3.6.1.4.1.4756.20.500.20.1.76 | ColumnnidPort7TxPausestsLocal | read-only | current | NID Series card Port7 tx pause status 0: No 1: Yes |
| 1.3.6.1.4.1.4756.20.500.20.1.77 | ColumnnidPort8LinkstsLocal | read-only | current | NID Series card Port8 link status: 0:Link down 1:Link up |
| 1.3.6.1.4.1.4756.20.500.20.1.78 | ColumnnidPort8SpeedstsLocal | read-only | current | NID Series card Port8 speed status 10Base-T 100Base-Tx 1000Base-Tx |
| 1.3.6.1.4.1.4756.20.500.20.1.79 | ColumnnidPort8DuplexstsLocal | read-only | current | NID Series card Port8 duplex status 0: Half 1: Full |
| 1.3.6.1.4.1.4756.20.500.20.1.80 | ColumnnidPort8RxPausestsLocal | read-only | current | NID Series card Port8 rx pause status 0: No 1: Yes |
| 1.3.6.1.4.1.4756.20.500.20.1.81 | ColumnnidPort8TxPausestsLocal | read-only | current | NID Series card Port8 tx pause status 0: No 1: Yes |
| 1.3.6.1.4.1.4756.20.500.20.1.82 | ColumnnidPort1SpeedConfLocal | read-write | current | NID Series card Port1 speed config 0: disable 1: auto 2: 100M FDX 3: 1G FDX 4: 2.5G FDX |
| 1.3.6.1.4.1.4756.20.500.20.1.83 | ColumnnidPort1flowConrolLocal | read-write | current | NID Series card Port1 flow control config 0: no 1: yes |
| 1.3.6.1.4.1.4756.20.500.20.1.84 | ColumnnidPort1MaxFrameLocal | read-write | current | NID Series card Port1 max frame config |
| 1.3.6.1.4.1.4756.20.500.20.1.85 | ColumnnidPort1ALSLocal | read-write | current | NID Series card Port1 auto laser shutdown: 0: Disable 1: Enable |
| 1.3.6.1.4.1.4756.20.500.20.1.86 | ColumnnidPort2SpeedConfLocal | read-write | current | NID Series card Port2 speed config 0: disable 1: auto 2: 100M FDX 3: 1G FDX 4: 2.5G FDX |
| 1.3.6.1.4.1.4756.20.500.20.1.87 | ColumnnidPort2flowConrolLocal | read-write | current | NID Series card Port2 flow control config 0: no 1: yes |
| 1.3.6.1.4.1.4756.20.500.20.1.88 | ColumnnidPort2MaxFrameLocal | read-write | current | NID Series card Port2 max frame config |
| 1.3.6.1.4.1.4756.20.500.20.1.89 | ColumnnidPort2ALSLocal | read-write | current | NID Series card Port2 auto laser shutdown: 0: Disable 1: Enable |
| 1.3.6.1.4.1.4756.20.500.20.1.90 | ColumnnidPort3SpeedConfLocal | read-write | current | NID Series card Port3 speed config 0: disable 1: auto 2: 100M FDX 3: 1G FDX |
| 1.3.6.1.4.1.4756.20.500.20.1.91 | ColumnnidPort3flowConrolLocal | read-write | current | NID Series card Port3 flow control config 0: no 1: yes |
| 1.3.6.1.4.1.4756.20.500.20.1.92 | ColumnnidPort3MaxFrameLocal | read-write | current | NID Series card Port3 max frame config |
| 1.3.6.1.4.1.4756.20.500.20.1.93 | ColumnnidPort3ALSLocal | read-write | current | NID Series card Port3 auto laser shutdown: 0: Disable 1: Enable |
| 1.3.6.1.4.1.4756.20.500.20.1.94 | ColumnnidPort4SpeedConfLocal | read-write | current | NID Series card Port4 speed config 0: disable 1: auto 2: 100M FDX 3: 1G FDX |
| 1.3.6.1.4.1.4756.20.500.20.1.95 | ColumnnidPort4flowConrolLocal | read-write | current | NID Series card Port4 flow control config 0: no 1: yes |
| 1.3.6.1.4.1.4756.20.500.20.1.96 | ColumnnidPort4MaxFrameLocal | read-write | current | NID Series card Port4 max frame config |
| 1.3.6.1.4.1.4756.20.500.20.1.97 | ColumnnidPort4ALSLocal | read-write | current | NID Series card Port4 auto laser shutdown: 0: Disable 1: Enable |
| 1.3.6.1.4.1.4756.20.500.20.1.98 | ColumnnidPort5SpeedConfLocal | read-write | current | NID Series card Port5 speed config 0: disable 1: auto 2: 10M HDX 3: 10M FDX 4: 100M HDX 5: 100M FDX 6: 1G FDX |
| 1.3.6.1.4.1.4756.20.500.20.1.99 | ColumnnidPort5flowConrolLocal | read-write | current | NID Series card Port5 flow control config 0: no 1: yes |
| 1.3.6.1.4.1.4756.20.500.20.1.100 | ColumnnidPort5MaxFrameLocal | read-write | current | NID Series card Port5 max frame config |
| 1.3.6.1.4.1.4756.20.500.20.1.101 | ColumnnidPort5CollisionModeLocal | read-write | current | NID Series card Port5 collision mode config. 0: Discard 1: Restart |
| 1.3.6.1.4.1.4756.20.500.20.1.102 | ColumnnidPort6SpeedConfLocal | read-write | current | NID Series card Port6 speed config 0: disable 1: auto 2: 10M HDX 3: 10M FDX 4: 100M HDX 5: 100M FDX 6: 1G FDX |
| 1.3.6.1.4.1.4756.20.500.20.1.103 | ColumnnidPort6flowConrolLocal | read-write | current | NID Series card Port6 flow control config 0: no 1: yes |
| 1.3.6.1.4.1.4756.20.500.20.1.104 | ColumnnidPort6MaxFrameLocal | read-write | current | NID Series card Port6 max frame config |
| 1.3.6.1.4.1.4756.20.500.20.1.105 | ColumnnidPort6CollisionModeLocal | read-write | current | NID Series card Port6 collision mode config. 0: Discard 1: Restart |
| 1.3.6.1.4.1.4756.20.500.20.1.106 | ColumnnidPort7SpeedConfLocal | read-write | current | NID Series card Port7 speed config 0: disable 1: auto 2: 10M HDX 3: 10M FDX 4: 100M HDX 5: 100M FDX 6: 1G FDX |
| 1.3.6.1.4.1.4756.20.500.20.1.107 | ColumnnidPort7flowConrolLocal | read-write | current | NID Series card Port7 flow control config 0: no 1: yes |
| 1.3.6.1.4.1.4756.20.500.20.1.108 | ColumnnidPort7MaxFrameLocal | read-write | current | NID Series card Port7 max frame config |
| 1.3.6.1.4.1.4756.20.500.20.1.109 | ColumnnidPort7CollisionModeLocal | read-write | current | NID Series card Port7 collision mode config. 0: Discard 1: Restart |
| 1.3.6.1.4.1.4756.20.500.20.1.110 | ColumnnidPort8SpeedConfLocal | read-write | current | NID Series card Port8 speed config 0: disable 1: auto 2: 10M HDX 3: 10M FDX 4: 100M HDX 5: 100M FDX 6: 1G FDX |
| 1.3.6.1.4.1.4756.20.500.20.1.111 | ColumnnidPort8flowConrolLocal | read-write | current | NID Series card Port8 flow control config 0: no 1: yes |
| 1.3.6.1.4.1.4756.20.500.20.1.112 | ColumnnidPort8MaxFrameLocal | read-write | current | NID Series card Port8 max frame config |
| 1.3.6.1.4.1.4756.20.500.20.1.113 | ColumnnidPort8CollisionModeLocal | read-write | current | NID Series card Port8 collision mode config. 0: Discard 1: Restart |
| 1.3.6.1.4.1.4756.20.500.20.1.114 | ColumnnidPort1LLFLogicLocal | read-write | current | NID Series card Port1 link loss forwarding - Logic 0: AND 1: OR |
| 1.3.6.1.4.1.4756.20.500.20.1.115 | ColumnnidPort1LLFLogicPort2Local | read-write | current | NID Series card Port1 link loss forwarding - Link/Rx Loss Port2 0: NO 1: YES |
| 1.3.6.1.4.1.4756.20.500.20.1.116 | ColumnnidPort1LLFLogicPort3Local | read-write | current | NID Series card Port1 link loss forwarding - Link/Rx Loss Port3 0: NO 1: YES |
| 1.3.6.1.4.1.4756.20.500.20.1.117 | ColumnnidPort1LLFLogicPort4Local | read-write | current | NID Series card Port1 link loss forwarding - Link/Rx Loss Port4 0: NO 1: YES |
| 1.3.6.1.4.1.4756.20.500.20.1.118 | ColumnnidPort1LLFLogicPort5Local | read-write | current | NID Series card Port1 link loss forwarding - Link/Rx Loss Port5 0: NO 1: YES |
| 1.3.6.1.4.1.4756.20.500.20.1.119 | ColumnnidPort1LLFLogicPort6Local | read-write | current | NID Series card Port1 link loss forwarding - Link/Rx Loss Port6 0: NO 1: YES |
| 1.3.6.1.4.1.4756.20.500.20.1.120 | ColumnnidPort1LLFLogicPort7Local | read-write | current | NID Series card Port1 link loss forwarding - Link/Rx Loss Port7 0: NO 1: YES |
| 1.3.6.1.4.1.4756.20.500.20.1.121 | ColumnnidPort1LLFLogicPort8Local | read-write | current | NID Series card Port1 link loss forwarding - Link/Rx Loss Port8 0: NO 1: YES |
| 1.3.6.1.4.1.4756.20.500.20.1.122 | ColumnnidPort2LLFLogicLocal | read-write | current | NID Series card Port2 link loss forwarding - Logic 0: AND 1: OR |
| 1.3.6.1.4.1.4756.20.500.20.1.123 | ColumnnidPort2LLFLogicPort1Local | read-write | current | NID Series card Port2 link loss forwarding - Link/Rx Loss Port1 0: NO 1: YES |
| 1.3.6.1.4.1.4756.20.500.20.1.124 | ColumnnidPort2LLFLogicPort3Local | read-write | current | NID Series card Port2 link loss forwarding - Link/Rx Loss Port3 0: NO 1: YES |
| 1.3.6.1.4.1.4756.20.500.20.1.125 | ColumnnidPort2LLFLogicPort4Local | read-write | current | NID Series card Port2 link loss forwarding - Link/Rx Loss Port4 0: NO 1: YES |
| 1.3.6.1.4.1.4756.20.500.20.1.126 | ColumnnidPort2LLFLogicPort5Local | read-write | current | NID Series card Port2 link loss forwarding - Link/Rx Loss Port54 0: NO 1: YES |
| 1.3.6.1.4.1.4756.20.500.20.1.127 | ColumnnidPort2LLFLogicPort6Local | read-write | current | NID Series card Port2 link loss forwarding - Link/Rx Loss Port6 0: NO 1: YES |
| 1.3.6.1.4.1.4756.20.500.20.1.128 | ColumnnidPort2LLFLogicPort7Local | read-write | current | NID Series card Port2 link loss forwarding - Link/Rx Loss Port7 0: NO 1: YES |
| 1.3.6.1.4.1.4756.20.500.20.1.129 | ColumnnidPort2LLFLogicPort8Local | read-write | current | NID Series card Port2 link loss forwarding - Link/Rx Loss Port8 0: NO 1: YES |
| 1.3.6.1.4.1.4756.20.500.20.1.130 | ColumnnidPort3LLFLogicLocal | read-write | current | NID Series card Port1 link loss forwarding - Logic 0: AND 1: OR |
| 1.3.6.1.4.1.4756.20.500.20.1.131 | ColumnnidPort3LLFLogicPort1Local | read-write | current | NID Series card Port3 link loss forwarding - Link/Rx Loss Port1 0: NO 1: YES |
| 1.3.6.1.4.1.4756.20.500.20.1.132 | ColumnnidPort3LLFLogicPort2Local | read-write | current | NID Series card Port3 link loss forwarding - Link/Rx Loss Port2 0: NO 1: YES |
| 1.3.6.1.4.1.4756.20.500.20.1.133 | ColumnnidPort3LLFLogicPort4Local | read-write | current | NID Series card Port3 link loss forwarding - Link/Rx Loss Port4 0: NO 1: YES |
| 1.3.6.1.4.1.4756.20.500.20.1.134 | ColumnnidPort3LLFLogicPort5Local | read-write | current | NID Series card Port3 link loss forwarding - Link/Rx Loss Port5 0: NO 1: YES |
| 1.3.6.1.4.1.4756.20.500.20.1.135 | ColumnnidPort3LLFLogicPort6Local | read-write | current | NID Series card Port3 link loss forwarding - Link/Rx Loss Port6 0: NO 1: YES |
| 1.3.6.1.4.1.4756.20.500.20.1.136 | ColumnnidPort3LLFLogicPort7Local | read-write | current | NID Series card Port3 link loss forwarding - Link/Rx Loss Port7 0: NO 1: YES |
| 1.3.6.1.4.1.4756.20.500.20.1.137 | ColumnnidPort3LLFLogicPort8Local | read-write | current | NID Series card Port3 link loss forwarding - Link/Rx Loss Port8 0: NO 1: YES |
| 1.3.6.1.4.1.4756.20.500.20.1.138 | ColumnnidPort4LLFLogicLocal | read-write | current | NID Series card Port4 link loss forwarding - Logic 0: AND 1: OR |
| 1.3.6.1.4.1.4756.20.500.20.1.139 | ColumnnidPort4LLFLogicPort1Local | read-write | current | NID Series card Port4 link loss forwarding - Link/Rx Loss Port1 0: NO 1: YES |
| 1.3.6.1.4.1.4756.20.500.20.1.140 | ColumnnidPort4LLFLogicPort2Local | read-write | current | NID Series card Port4 link loss forwarding - Link/Rx Loss Port2 0: NO 1: YES |
| 1.3.6.1.4.1.4756.20.500.20.1.141 | ColumnnidPort4LLFLogicPort3Local | read-write | current | NID Series card Port4 link loss forwarding - Link/Rx Loss Port3 0: NO 1: YES |
| 1.3.6.1.4.1.4756.20.500.20.1.142 | ColumnnidPort4LLFLogicPort5Local | read-write | current | NID Series card Port4 link loss forwarding - Link/Rx Loss Port5 0: NO 1: YES |
| 1.3.6.1.4.1.4756.20.500.20.1.143 | ColumnnidPort4LLFLogicPort6Local | read-write | current | NID Series card Port4 link loss forwarding - Link/Rx Loss Port6 0: NO 1: YES |
| 1.3.6.1.4.1.4756.20.500.20.1.144 | ColumnnidPort4LLFLogicPort7Local | read-write | current | NID Series card Port4 link loss forwarding - Link/Rx Loss Port7 0: NO 1: YES |
| 1.3.6.1.4.1.4756.20.500.20.1.145 | ColumnnidPort4LLFLogicPort8Local | read-write | current | NID Series card Port4 link loss forwarding - Link/Rx Loss Port8 0: NO 1: YES |
| 1.3.6.1.4.1.4756.20.500.20.1.146 | ColumnnidPort5LLFLogicLocal | read-write | current | NID Series card Port5 link loss forwarding - Logic 0: AND 1: OR |
| 1.3.6.1.4.1.4756.20.500.20.1.147 | ColumnnidPort5LLFLogicPort1Local | read-write | current | NID Series card Port5 link loss forwarding - Link/Rx Loss Port1 0: NO 1: YES |
| 1.3.6.1.4.1.4756.20.500.20.1.148 | ColumnnidPort5LLFLogicPort2Local | read-write | current | NID Series card Port5 link loss forwarding - Link/Rx Loss Port2 0: NO 1: YES |
| 1.3.6.1.4.1.4756.20.500.20.1.149 | ColumnnidPort5LLFLogicPort3Local | read-write | current | NID Series card Port5 link loss forwarding - Link/Rx Loss Port3 0: NO 1: YES |
| 1.3.6.1.4.1.4756.20.500.20.1.150 | ColumnnidPort5LLFLogicPort4Local | read-write | current | NID Series card Port5 link loss forwarding - Link/Rx Loss Port4 0: NO 1: YES |
| 1.3.6.1.4.1.4756.20.500.20.1.151 | ColumnnidPort5LLFLogicPort6Local | read-write | current | NID Series card Port5 link loss forwarding - Link/Rx Loss Port6 0: NO 1: YES |
| 1.3.6.1.4.1.4756.20.500.20.1.152 | ColumnnidPort5LLFLogicPort7Local | read-write | current | NID Series card Port5 link loss forwarding - Link/Rx Loss Port7 0: NO 1: YES |
| 1.3.6.1.4.1.4756.20.500.20.1.153 | ColumnnidPort5LLFLogicPort8Local | read-write | current | NID Series card Port5 link loss forwarding - Link/Rx Loss Port8 0: NO 1: YES |
| 1.3.6.1.4.1.4756.20.500.20.1.154 | ColumnnidPort6LLFLogicLocal | read-write | current | NID Series card Port6 link loss forwarding - Logic 0: AND 1: OR |
| 1.3.6.1.4.1.4756.20.500.20.1.155 | ColumnnidPort6LLFLogicPort1Local | read-write | current | NID Series card Port6 link loss forwarding - Link/Rx Loss Port1 0: NO 1: YES |
| 1.3.6.1.4.1.4756.20.500.20.1.156 | ColumnnidPort6LLFLogicPort2Local | read-write | current | NID Series card Port6 link loss forwarding - Link/Rx Loss Port2 0: NO 1: YES |
| 1.3.6.1.4.1.4756.20.500.20.1.157 | ColumnnidPort6LLFLogicPort3Local | read-write | current | NID Series card Port6 link loss forwarding - Link/Rx Loss Port3 0: NO 1: YES |
| 1.3.6.1.4.1.4756.20.500.20.1.158 | ColumnnidPort6LLFLogicPort4Local | read-write | current | NID Series card Port6 link loss forwarding - Link/Rx Loss Port4 0: NO 1: YES |
| 1.3.6.1.4.1.4756.20.500.20.1.159 | ColumnnidPort6LLFLogicPort5Local | read-write | current | NID Series card Port6 link loss forwarding - Link/Rx Loss Port5 0: NO 1: YES |
| 1.3.6.1.4.1.4756.20.500.20.1.160 | ColumnnidPort6LLFLogicPort7Local | read-write | current | NID Series card Port4 link loss forwarding - Link/Rx Loss Port7 0: NO 1: YES |
| 1.3.6.1.4.1.4756.20.500.20.1.161 | ColumnnidPort6LLFLogicPort8Local | read-write | current | NID Series card Port6 link loss forwarding - Link/Rx Loss Port8 0: NO 1: YES |
| 1.3.6.1.4.1.4756.20.500.20.1.162 | ColumnnidPort7LLFLogicLocal | read-write | current | NID Series card Port7 link loss forwarding - Logic 0: AND 1: OR |
| 1.3.6.1.4.1.4756.20.500.20.1.163 | ColumnnidPort7LLFLogicPort1Local | read-write | current | NID Series card Port7 link loss forwarding - Link/Rx Loss Port1 0: NO 1: YES |
| 1.3.6.1.4.1.4756.20.500.20.1.164 | ColumnnidPort7LLFLogicPort2Local | read-write | current | NID Series card Port7 link loss forwarding - Link/Rx Loss Port2 0: NO 1: YES |
| 1.3.6.1.4.1.4756.20.500.20.1.165 | ColumnnidPort7LLFLogicPort3Local | read-write | current | NID Series card Port7 link loss forwarding - Link/Rx Loss Port3 0: NO 1: YES |
| 1.3.6.1.4.1.4756.20.500.20.1.166 | ColumnnidPort7LLFLogicPort4Local | read-write | current | NID Series card Port7 link loss forwarding - Link/Rx Loss Port4 0: NO 1: YES |
| 1.3.6.1.4.1.4756.20.500.20.1.167 | ColumnnidPort7LLFLogicPort5Local | read-write | current | NID Series card Port7 link loss forwarding - Link/Rx Loss Port5 0: NO 1: YES |
| 1.3.6.1.4.1.4756.20.500.20.1.168 | ColumnnidPort7LLFLogicPort6Local | read-write | current | NID Series card Port4 link loss forwarding - Link/Rx Loss Port6 0: NO 1: YES |
| 1.3.6.1.4.1.4756.20.500.20.1.169 | ColumnnidPort7LLFLogicPort8Local | read-write | current | NID Series card Port7 link loss forwarding - Link/Rx Loss Port8 0: NO 1: YES |
| 1.3.6.1.4.1.4756.20.500.20.1.170 | ColumnnidPort8LLFLogicLocal | read-write | current | NID Series card Port8 link loss forwarding - Logic 0: AND 1: OR |
| 1.3.6.1.4.1.4756.20.500.20.1.171 | ColumnnidPort8LLFLogicPort1Local | read-write | current | NID Series card Port8 link loss forwarding - Link/Rx Loss Port1 0: NO 1: YES |
| 1.3.6.1.4.1.4756.20.500.20.1.172 | ColumnnidPort8LLFLogicPort2Local | read-write | current | NID Series card Port8 link loss forwarding - Link/Rx Loss Port2 0: NO 1: YES |
| 1.3.6.1.4.1.4756.20.500.20.1.173 | ColumnnidPort8LLFLogicPort3Local | read-write | current | NID Series card Port5 link loss forwarding - Link/Rx Loss Port3 0: NO 1: YES |
| 1.3.6.1.4.1.4756.20.500.20.1.174 | ColumnnidPort8LLFLogicPort4Local | read-write | current | NID Series card Port8 link loss forwarding - Link/Rx Loss Port4 0: NO 1: YES |
| 1.3.6.1.4.1.4756.20.500.20.1.175 | ColumnnidPort8LLFLogicPort5Local | read-write | current | NID Series card Port8 link loss forwarding - Link/Rx Loss Port5 0: NO 1: YES |
| 1.3.6.1.4.1.4756.20.500.20.1.176 | ColumnnidPort8LLFLogicPort6Local | read-write | current | NID Series card Port8 link loss forwarding - Link/Rx Loss Port6 0: NO 1: YES |
| 1.3.6.1.4.1.4756.20.500.20.1.177 | ColumnnidPort8LLFLogicPort7Local | read-write | current | NID Series card Port8 link loss forwarding - Link/Rx Loss Port7 0: NO 1: YES |
| 1.3.6.1.4.1.4756.20.500.20.1.178 | ColumnnidPort1PacketsRxLocal | read-only | current | NID Series card port1 traffic overview:: Packets Rx |
| 1.3.6.1.4.1.4756.20.500.20.1.179 | ColumnnidPort1PacketsTxLocal | read-only | current | NID Series card port1 traffic overview:: Packets Tx |
| 1.3.6.1.4.1.4756.20.500.20.1.180 | ColumnnidPort1BytesRxLocal | read-only | current | NID Series card port1 traffic overview:: Bytes Rx |
| 1.3.6.1.4.1.4756.20.500.20.1.181 | ColumnnidPort1BytesTxLocal | read-only | current | NID Series card port1 traffic overview:: Bytes Tx |
| 1.3.6.1.4.1.4756.20.500.20.1.182 | ColumnnidPort1ErrorsRxLocal | read-only | current | NID Series card port1 traffic overview:: Errors Rx |
| 1.3.6.1.4.1.4756.20.500.20.1.183 | ColumnnidPort1ErrorsTxLocal | read-only | current | NID Series card port1 traffic overview:: Errors Tx |
| 1.3.6.1.4.1.4756.20.500.20.1.184 | ColumnnidPort1DropsRxLocal | read-only | current | NID Series card port1 traffic overview:: Drops Rx |
| 1.3.6.1.4.1.4756.20.500.20.1.185 | ColumnnidPort1DropsTxLocal | read-only | current | NID Series card port1 traffic overview:: Drops Tx |
| 1.3.6.1.4.1.4756.20.500.20.1.186 | ColumnnidPort1FilteredRxLocal | read-only | current | NID Series card port1 traffic overview:: Filtered Rx |
| 1.3.6.1.4.1.4756.20.500.20.1.187 | ColumnnidPort2PacketsRxLocal | read-only | current | NID Series card port2 traffic overview:: Packets Rx |
| 1.3.6.1.4.1.4756.20.500.20.1.188 | ColumnnidPort2PacketsTxLocal | read-only | current | NID Series card port2 traffic overview:: Packets Tx |
| 1.3.6.1.4.1.4756.20.500.20.1.189 | ColumnnidPort2BytesRxLocal | read-only | current | NID Series card port2 traffic overview:: Bytes Rx |
| 1.3.6.1.4.1.4756.20.500.20.1.190 | ColumnnidPort2BytesTxLocal | read-only | current | NID Series card port2 traffic overview:: Bytes Tx |
| 1.3.6.1.4.1.4756.20.500.20.1.191 | ColumnnidPort2ErrorsRxLocal | read-only | current | NID Series card port2 traffic overview:: Errors Rx |
| 1.3.6.1.4.1.4756.20.500.20.1.192 | ColumnnidPort2ErrorsTxLocal | read-only | current | NID Series card port2 traffic overview:: Errors Tx |
| 1.3.6.1.4.1.4756.20.500.20.1.193 | ColumnnidPort2DropsRxLocal | read-only | current | NID Series card port2 traffic overview:: Drops Rx |
| 1.3.6.1.4.1.4756.20.500.20.1.194 | ColumnnidPort2DropsTxLocal | read-only | current | NID Series card port2 traffic overview:: Drops Tx |
| 1.3.6.1.4.1.4756.20.500.20.1.195 | ColumnnidPort2FilteredRxLocal | read-only | current | NID Series card port2 traffic overview:: Filtered Rx |
| 1.3.6.1.4.1.4756.20.500.20.1.196 | ColumnnidPort3PacketsRxLocal | read-only | current | NID Series card port3 traffic overview:: Packets Rx |
| 1.3.6.1.4.1.4756.20.500.20.1.197 | ColumnnidPort3PacketsTxLocal | read-only | current | NID Series card port3 traffic overview:: Packets Tx |
| 1.3.6.1.4.1.4756.20.500.20.1.198 | ColumnnidPort3BytesRxLocal | read-only | current | NID Series card port3 traffic overview:: Bytes Rx |
| 1.3.6.1.4.1.4756.20.500.20.1.199 | ColumnnidPort3BytesTxLocal | read-only | current | NID Series card port3 traffic overview:: Bytes Tx |
| 1.3.6.1.4.1.4756.20.500.20.1.200 | ColumnnidPort3ErrorsRxLocal | read-only | current | NID Series card port3 traffic overview:: Errors Rx |
| 1.3.6.1.4.1.4756.20.500.20.1.201 | ColumnnidPort3ErrorsTxLocal | read-only | current | NID Series card port3 traffic overview:: Errors Tx |
| 1.3.6.1.4.1.4756.20.500.20.1.202 | ColumnnidPort3DropsRxLocal | read-only | current | NID Series card port3 traffic overview:: Drops Rx |
| 1.3.6.1.4.1.4756.20.500.20.1.203 | ColumnnidPort3DropsTxLocal | read-only | current | NID Series card port3 traffic overview:: Drops Tx |
| 1.3.6.1.4.1.4756.20.500.20.1.204 | ColumnnidPort3FilteredRxLocal | read-only | current | NID Series card port3 traffic overview:: Filtered Rx |
| 1.3.6.1.4.1.4756.20.500.20.1.205 | ColumnnidPort4PacketsRxLocal | read-only | current | NID Series card port4 traffic overview:: Packets Rx |
| 1.3.6.1.4.1.4756.20.500.20.1.206 | ColumnnidPort4PacketsTxLocal | read-only | current | NID Series card port4 traffic overview:: Packets Tx |
| 1.3.6.1.4.1.4756.20.500.20.1.207 | ColumnnidPort4BytesRxLocal | read-only | current | NID Series card port4 traffic overview:: Bytes Rx |
| 1.3.6.1.4.1.4756.20.500.20.1.208 | ColumnnidPort4BytesTxLocal | read-only | current | NID Series card port4 traffic overview:: Bytes Tx |
| 1.3.6.1.4.1.4756.20.500.20.1.209 | ColumnnidPort4ErrorsRxLocal | read-only | current | NID Series card port4 traffic overview:: Errors Rx |
| 1.3.6.1.4.1.4756.20.500.20.1.210 | ColumnnidPort4ErrorsTxLocal | read-only | current | NID Series card port4 traffic overview:: Errors Tx |
| 1.3.6.1.4.1.4756.20.500.20.1.211 | ColumnnidPort4DropsRxLocal | read-only | current | NID Series card port4 traffic overview:: Drops Rx |
| 1.3.6.1.4.1.4756.20.500.20.1.212 | ColumnnidPort4DropsTxLocal | read-only | current | NID Series card port4 traffic overview:: Drops Tx |
| 1.3.6.1.4.1.4756.20.500.20.1.213 | ColumnnidPort4FilteredRxLocal | read-only | current | NID Series card port4 traffic overview:: Filtered Rx |
| 1.3.6.1.4.1.4756.20.500.20.1.214 | ColumnnidPort5PacketsRxLocal | read-only | current | NID Series card port5 traffic overview:: Packets Rx |
| 1.3.6.1.4.1.4756.20.500.20.1.215 | ColumnnidPort5PacketsTxLocal | read-only | current | NID Series card port5 traffic overview:: Packets Tx |
| 1.3.6.1.4.1.4756.20.500.20.1.216 | ColumnnidPort5BytesRxLocal | read-only | current | NID Series card port5 traffic overview:: Bytes Rx |
| 1.3.6.1.4.1.4756.20.500.20.1.217 | ColumnnidPort5BytesTxLocal | read-only | current | NID Series card port5 traffic overview:: Bytes Tx |
| 1.3.6.1.4.1.4756.20.500.20.1.218 | ColumnnidPort5ErrorsRxLocal | read-only | current | NID Series card port5 traffic overview:: Errors Rx |
| 1.3.6.1.4.1.4756.20.500.20.1.219 | ColumnnidPort5ErrorsTxLocal | read-only | current | NID Series card port5 traffic overview:: Errors Tx |
| 1.3.6.1.4.1.4756.20.500.20.1.220 | ColumnnidPort5DropsRxLocal | read-only | current | NID Series card port5 traffic overview:: Drops Rx |
| 1.3.6.1.4.1.4756.20.500.20.1.221 | ColumnnidPort5DropsTxLocal | read-only | current | NID Series card port5 traffic overview:: Drops Tx |
| 1.3.6.1.4.1.4756.20.500.20.1.222 | ColumnnidPort5FilteredRxLocal | read-only | current | NID Series card port5 traffic overview:: Filtered Rx |
| 1.3.6.1.4.1.4756.20.500.20.1.223 | ColumnnidPort6PacketsRxLocal | read-only | current | NID Series card port6 traffic overview:: Packets Rx |
| 1.3.6.1.4.1.4756.20.500.20.1.224 | ColumnnidPort6PacketsTxLocal | read-only | current | NID Series card port6 traffic overview:: Packets Tx |
| 1.3.6.1.4.1.4756.20.500.20.1.225 | ColumnnidPort6BytesRxLocal | read-only | current | NID Series card port6 traffic overview:: Bytes Rx |
| 1.3.6.1.4.1.4756.20.500.20.1.226 | ColumnnidPort6BytesTxLocal | read-only | current | NID Series card port6 traffic overview:: Bytes Tx |
| 1.3.6.1.4.1.4756.20.500.20.1.227 | ColumnnidPort6ErrorsRxLocal | read-only | current | NID Series card port6 traffic overview:: Errors Rx |
| 1.3.6.1.4.1.4756.20.500.20.1.228 | ColumnnidPort6ErrorsTxLocal | read-only | current | NID Series card port6 traffic overview:: Errors Tx |
| 1.3.6.1.4.1.4756.20.500.20.1.229 | ColumnnidPort6DropsRxLocal | read-only | current | NID Series card port6 traffic overview:: Drops Rx |
| 1.3.6.1.4.1.4756.20.500.20.1.230 | ColumnnidPort6DropsTxLocal | read-only | current | NID Series card port6 traffic overview:: Drops Tx |
| 1.3.6.1.4.1.4756.20.500.20.1.231 | ColumnnidPort6FilteredRxLocal | read-only | current | NID Series card port6 traffic overview:: Filtered Rx |
| 1.3.6.1.4.1.4756.20.500.20.1.232 | ColumnnidPort7PacketsRxLocal | read-only | current | NID Series card port7 traffic overview:: Packets Rx |
| 1.3.6.1.4.1.4756.20.500.20.1.233 | ColumnnidPort7PacketsTxLocal | read-only | current | NID Series card port7 traffic overview:: Packets Tx |
| 1.3.6.1.4.1.4756.20.500.20.1.234 | ColumnnidPort7BytesRxLocal | read-only | current | NID Series card port7 traffic overview:: Bytes Rx |
| 1.3.6.1.4.1.4756.20.500.20.1.235 | ColumnnidPort7BytesTxLocal | read-only | current | NID Series card port7 traffic overview:: Bytes Tx |
| 1.3.6.1.4.1.4756.20.500.20.1.236 | ColumnnidPort7ErrorsRxLocal | read-only | current | NID Series card port7 traffic overview:: Errors Rx |
| 1.3.6.1.4.1.4756.20.500.20.1.237 | ColumnnidPort7ErrorsTxLocal | read-only | current | NID Series card port7 traffic overview:: Errors Tx |
| 1.3.6.1.4.1.4756.20.500.20.1.238 | ColumnnidPort7DropsRxLocal | read-only | current | NID Series card port7 traffic overview:: Drops Rx |
| 1.3.6.1.4.1.4756.20.500.20.1.239 | ColumnnidPort7DropsTxLocal | read-only | current | NID Series card port7 traffic overview:: Drops Tx |
| 1.3.6.1.4.1.4756.20.500.20.1.240 | ColumnnidPort7FilteredRxLocal | read-only | current | NID Series card port7 traffic overview:: Filtered Rx |
| 1.3.6.1.4.1.4756.20.500.20.1.241 | ColumnnidPort8PacketsRxLocal | read-only | current | NID Series card port8 traffic overview:: Packets Rx |
| 1.3.6.1.4.1.4756.20.500.20.1.242 | ColumnnidPort8PacketsTxLocal | read-only | current | NID Series card port8 traffic overview:: Packets Tx |
| 1.3.6.1.4.1.4756.20.500.20.1.243 | ColumnnidPort8BytesRxLocal | read-only | current | NID Series card port8 traffic overview:: Bytes Rx |
| 1.3.6.1.4.1.4756.20.500.20.1.244 | ColumnnidPort8BytesTxLocal | read-only | current | NID Series card port8 traffic overview:: Bytes Tx |
| 1.3.6.1.4.1.4756.20.500.20.1.245 | ColumnnidPort8ErrorsRxLocal | read-only | current | NID Series card port8 traffic overview:: Errors Rx |
| 1.3.6.1.4.1.4756.20.500.20.1.246 | ColumnnidPort8ErrorsTxLocal | read-only | current | NID Series card port8 traffic overview:: Errors Tx |
| 1.3.6.1.4.1.4756.20.500.20.1.247 | ColumnnidPort8DropsRxLocal | read-only | current | NID Series card port8 traffic overview:: Drops Rx |
| 1.3.6.1.4.1.4756.20.500.20.1.248 | ColumnnidPort8DropsTxLocal | read-only | current | NID Series card port8 traffic overview:: Drops Tx |
| 1.3.6.1.4.1.4756.20.500.20.1.249 | ColumnnidPort8FilteredRxLocal | read-only | current | NID Series card port8 traffic overview:: Filtered Rx |
| 1.3.6.1.4.1.4756.20.500.20.1.250 | ColumnnidAggrSourceMACAddrLocal | read-write | current | NID Series card Aggregation Mode Configuration: Source MAC Address 0: No 1: Yes |
| 1.3.6.1.4.1.4756.20.500.20.1.251 | ColumnnidAggrDestinationMACAddrLocal | read-write | current | NID Series card Aggregation Mode Configuration: Destination MAC Address 0: No 1: Yes |
| 1.3.6.1.4.1.4756.20.500.20.1.252 | ColumnnidAggrIPAddrLocal | read-write | current | NID Series card Aggregation Mode Configuration: IP Address 0: No 1: Yes |
| 1.3.6.1.4.1.4756.20.500.20.1.253 | ColumnnidAggrTCPUDPPortNumLocal | read-write | current | NID Series card Aggregation Mode Configuration: TCP/UDP Port Number 0: No 1: Yes |
| 1.3.6.1.4.1.4756.20.500.20.1.254 | ColumnnidAggrGroupPort1ConfLocal | read-write | current | NID Series card Aggregation Group Port1 Configuration: 0: Normal 1: ID1 2: ID2 3: ID3 4: ID4 |
| 1.3.6.1.4.1.4756.20.500.20.1.255 | ColumnnidAggrGroupPort2ConfLocal | read-write | current | NID Series card Aggregation Group Port2 Configuration: 0: Normal 1: ID1 2: ID2 3: ID3 4: ID4 |
| 1.3.6.1.4.1.4756.20.500.20.1.256 | ColumnnidAggrGroupPort3ConfLocal | read-write | current | NID Series card Aggregation Group Port3 Configuration: 0: Normal 1: ID1 2: ID2 3: ID3 4: ID4 |
| 1.3.6.1.4.1.4756.20.500.20.1.257 | ColumnnidAggrGroupPort4ConfLocal | read-write | current | NID Series card Aggregation Group Port4 Configuration: 0: Normal 1: ID1 2: ID2 3: ID3 4: ID4 |
| 1.3.6.1.4.1.4756.20.500.20.1.258 | ColumnnidAggrGroupPort5ConfLocal | read-write | current | NID Series card Aggregation Group Port5 Configuration: 0: Normal 1: ID1 2: ID2 3: ID3 4: ID4 |
| 1.3.6.1.4.1.4756.20.500.20.1.259 | ColumnnidAggrGroupPort6ConfLocal | read-write | current | NID Series card Aggregation Group Port6 Configuration: 0: Normal 1: ID1 2: ID2 3: ID3 4: ID4 |
| 1.3.6.1.4.1.4756.20.500.20.1.260 | ColumnnidAggrGroupPort7ConfLocal | read-write | current | NID Series card Aggregation Group Port7 Configuration: 0: Normal 1: ID1 2: ID2 3: ID3 4: ID4 |
| 1.3.6.1.4.1.4756.20.500.20.1.261 | ColumnnidAggrGroupPort8ConfLocal | read-write | current | NID Series card Aggregation Group Port8 Configuration: 0: Normal 1: ID1 2: ID2 3: ID3 4: ID4 |
| 1.3.6.1.4.1.4756.20.500.20.1.262 | ColumnnidPort1LACPEnabledLocal | read-write | current | NID Series card Port1 LACP Enabled: 0: No 1: Yes |
| 1.3.6.1.4.1.4756.20.500.20.1.263 | ColumnnidPort1LACPKEYLocal | read-write | current | NID Series card Port1 LACP Key value: The Key value incurred by the port, range 0-65535.The value of 0 means auto. |
| 1.3.6.1.4.1.4756.20.500.20.1.264 | ColumnnidPort1LACPRoleLocal | read-write | current | NID Series card Port1 LACP Role: 0: Passive 1: Active |
| 1.3.6.1.4.1.4756.20.500.20.1.265 | ColumnnidPort1LACPTimeOutLocal | read-write | current | NID Series card Port1 LACP Time out: 0: Slow 1: Fast |
| 1.3.6.1.4.1.4756.20.500.20.1.266 | ColumnnidPort1LACPPrioLocal | read-write | current | NID Series card Port1 LACP priority: The Key value incurred by the port, range 1-65535. |
| 1.3.6.1.4.1.4756.20.500.20.1.267 | ColumnnidPort2LACPEnabledLocal | read-write | current | NID Series card Port2 LACP Enabled: 0: No 1: Yes |
| 1.3.6.1.4.1.4756.20.500.20.1.268 | ColumnnidPort2LACPKEYLocal | read-write | current | NID Series card Port2 LACP Key value: The Key value incurred by the port, range 0-65535.The value of 0 means auto. |
| 1.3.6.1.4.1.4756.20.500.20.1.269 | ColumnnidPort2LACPRoleLocal | read-write | current | NID Series card Port2 LACP Role: 0: Passive 1: Active |
| 1.3.6.1.4.1.4756.20.500.20.1.270 | ColumnnidPort2LACPTimeOutLocal | read-write | current | NID Series card Port2 LACP Time out: 0: Slow 1: Fast |
| 1.3.6.1.4.1.4756.20.500.20.1.271 | ColumnnidPort2LACPPrioLocal | read-write | current | NID Series card Port2 LACP priority: The Key value incurred by the port, range 1-65535. |
| 1.3.6.1.4.1.4756.20.500.20.1.272 | ColumnnidPort3LACPEnabledLocal | read-write | current | NID Series card Port3 LACP Enabled: 0: No 1: Yes |
| 1.3.6.1.4.1.4756.20.500.20.1.273 | ColumnnidPort3LACPKEYLocal | read-write | current | NID Series card Port3 LACP Key value: The Key value incurred by the port, range 0-65535.The value of 0 means auto. |
| 1.3.6.1.4.1.4756.20.500.20.1.274 | ColumnnidPort3LACPRoleLocal | read-write | current | NID Series card Port3 LACP Role: 0: Passive 1: Active |
| 1.3.6.1.4.1.4756.20.500.20.1.275 | ColumnnidPort3LACPTimeOutLocal | read-write | current | NID Series card Port3 LACP Time out: 0: Slow 1: Fast |
| 1.3.6.1.4.1.4756.20.500.20.1.276 | ColumnnidPort3LACPPrioLocal | read-write | current | NID Series card Port3 LACP priority: The Key value incurred by the port, range 1-65535. |
| 1.3.6.1.4.1.4756.20.500.20.1.277 | ColumnnidPort4LACPEnabledLocal | read-write | current | NID Series card Port4 LACP Enabled: 0: No 1: Yes |
| 1.3.6.1.4.1.4756.20.500.20.1.278 | ColumnnidPort4LACPKEYLocal | read-write | current | NID Series card Port4 LACP Key value: The Key value incurred by the port, range 0-65535.The value of 0 means auto. |
| 1.3.6.1.4.1.4756.20.500.20.1.279 | ColumnnidPort4LACPRoleLocal | read-write | current | NID Series card Port4 LACP Role: 0: Passive 1: Active |
| 1.3.6.1.4.1.4756.20.500.20.1.280 | ColumnnidPort4LACPTimeOutLocal | read-write | current | NID Series card Port4 LACP Time out: 0: Slow 1: Fast |
| 1.3.6.1.4.1.4756.20.500.20.1.281 | ColumnnidPort4LACPPrioLocal | read-write | current | NID Series card Port4 LACP priority: The Key value incurred by the port, range 1-65535. |
| 1.3.6.1.4.1.4756.20.500.20.1.282 | ColumnnidPort5LACPEnabledLocal | read-write | current | NID Series card Port5 LACP Enabled: 0: No 1: Yes |
| 1.3.6.1.4.1.4756.20.500.20.1.283 | ColumnnidPort5LACPKEYLocal | read-write | current | NID Series card Port5 LACP Key value: The Key value incurred by the port, range 0-65535.The value of 0 means auto. |
| 1.3.6.1.4.1.4756.20.500.20.1.284 | ColumnnidPort5LACPRoleLocal | read-write | current | NID Series card Port5 LACP Role: 0: Passive 1: Active |
| 1.3.6.1.4.1.4756.20.500.20.1.285 | ColumnnidPort5LACPTimeOutLocal | read-write | current | NID Series card Port5 LACP Time out: 0: Slow 1: Fast |
| 1.3.6.1.4.1.4756.20.500.20.1.286 | ColumnnidPort5LACPPrioLocal | read-write | current | NID Series card Port5 LACP priority: The Key value incurred by the port, range 1-65535. |
| 1.3.6.1.4.1.4756.20.500.20.1.287 | ColumnnidPort6LACPEnabledLocal | read-write | current | NID Series card Port6 LACP Enabled: 0: No 1: Yes |
| 1.3.6.1.4.1.4756.20.500.20.1.288 | ColumnnidPort6LACPKEYLocal | read-write | current | NID Series card Port6 LACP Key value: The Key value incurred by the port, range 0-65535.The value of 0 means auto. |
| 1.3.6.1.4.1.4756.20.500.20.1.289 | ColumnnidPort6LACPRoleLocal | read-write | current | NID Series card Port6 LACP Role: 0: Passive 1: Active |
| 1.3.6.1.4.1.4756.20.500.20.1.290 | ColumnnidPort6LACPTimeOutLocal | read-write | current | NID Series card Port6 LACP Time out: 0: Slow 1: Fast |
| 1.3.6.1.4.1.4756.20.500.20.1.291 | ColumnnidPort6LACPPrioLocal | read-write | current | NID Series card Port6 LACP priority: The Key value incurred by the port, range 1-65535. |
| 1.3.6.1.4.1.4756.20.500.20.1.292 | ColumnnidPort7LACPEnabledLocal | read-write | current | NID Series card Port7 LACP Enabled: 0: No 1: Yes |
| 1.3.6.1.4.1.4756.20.500.20.1.293 | ColumnnidPort7LACPKEYLocal | read-write | current | NID Series card Port7 LACP Key value: The Key value incurred by the port, range 0-65535.The value of 0 means auto. |
| 1.3.6.1.4.1.4756.20.500.20.1.294 | ColumnnidPort7LACPRoleLocal | read-write | current | NID Series card Port7 LACP Role: 0: Passive 1: Active |
| 1.3.6.1.4.1.4756.20.500.20.1.295 | ColumnnidPort7LACPTimeOutLocal | read-write | current | NID Series card Port7 LACP Time out: 0: Slow 1: Fast |
| 1.3.6.1.4.1.4756.20.500.20.1.296 | ColumnnidPort7LACPPrioLocal | read-write | current | NID Series card Port7 LACP priority: The Key value incurred by the port, range 1-65535. |
| 1.3.6.1.4.1.4756.20.500.20.1.297 | ColumnnidPort8LACPEnabledLocal | read-write | current | NID Series card Port8 LACP Enabled: 0: No 1: Yes |
| 1.3.6.1.4.1.4756.20.500.20.1.298 | ColumnnidPort8LACPKEYLocal | read-write | current | NID Series card Port8 LACP Key value: The Key value incurred by the port, range 0-65535.The value of 0 means auto. |
| 1.3.6.1.4.1.4756.20.500.20.1.299 | ColumnnidPort8LACPRoleLocal | read-write | current | NID Series card Port8 LACP Role: 0: Passive 1: Active |
| 1.3.6.1.4.1.4756.20.500.20.1.300 | ColumnnidPort8LACPTimeOutLocal | read-write | current | NID Series card Port8 LACP Time out: 0: Slow 1: Fast |
| 1.3.6.1.4.1.4756.20.500.20.1.301 | ColumnnidPort8LACPPrioLocal | read-write | current | NID Series card Port8 LACP priority: The Key value incurred by the port, range 1-65535. |
| 1.3.6.1.4.1.4756.20.500.20.1.302 | ColumnnidPort1LACPstsLocal | read-only | current | NID Series card Port1 LACP status: 0: No 1: Yes 2: Standby |
| 1.3.6.1.4.1.4756.20.500.20.1.303 | ColumnnidPort1LACPKEYstsLocal | read-only | current | NID Series card Port1 LACP status: Key |
| 1.3.6.1.4.1.4756.20.500.20.1.304 | ColumnnidPort1LACPAggrIDstsLocal | read-only | current | NID Series card Port1 LACP status: Aggr ID |
| 1.3.6.1.4.1.4756.20.500.20.1.305 | ColumnnidPort1LACPParnterSysIDstsLocal | read-only | current | NID Series card Port1 LACP status: Parnter System ID |
| 1.3.6.1.4.1.4756.20.500.20.1.306 | ColumnnidPort1LACPParnterPortstsLocal | read-only | current | NID Series card Port1 LACP status: Parnter Port Status |
| 1.3.6.1.4.1.4756.20.500.20.1.307 | ColumnnidPort1LACPParnterProistsLocal | read-only | current | NID Series card Port1 LACP status: Parnter Priority |
| 1.3.6.1.4.1.4756.20.500.20.1.308 | ColumnnidPort2LACPstsLocal | read-only | current | NID Series card Port2 LACP status: 0: No 1: Yes 2: Standby |
| 1.3.6.1.4.1.4756.20.500.20.1.309 | ColumnnidPort2LACPKEYstsLocal | read-only | current | NID Series card Port2 LACP status: Key |
| 1.3.6.1.4.1.4756.20.500.20.1.310 | ColumnnidPort2LACPAggrIDstsLocal | read-only | current | NID Series card Port2 LACP status: Aggr ID |
| 1.3.6.1.4.1.4756.20.500.20.1.311 | ColumnnidPort2LACPParnterSysIDstsLocal | read-only | current | NID Series card Port2 LACP status: Parnter System ID |
| 1.3.6.1.4.1.4756.20.500.20.1.312 | ColumnnidPort2LACPParnterPortstsLocal | read-only | current | NID Series card Port2 LACP status: Parnter Port Status |
| 1.3.6.1.4.1.4756.20.500.20.1.313 | ColumnnidPort2LACPParnterProistsLocal | read-only | current | NID Series card Port2 LACP status: Parnter Priority |
| 1.3.6.1.4.1.4756.20.500.20.1.314 | ColumnnidPort3LACPstsLocal | read-only | current | NID Series card Port3 LACP status: 0: No 1: Yes 2: Standby |
| 1.3.6.1.4.1.4756.20.500.20.1.315 | ColumnnidPort3LACPKEYstsLocal | read-only | current | NID Series card Port3 LACP status: Key |
| 1.3.6.1.4.1.4756.20.500.20.1.316 | ColumnnidPort3LACPAggrIDstsLocal | read-only | current | NID Series card Port3 LACP status: Aggr ID |
| 1.3.6.1.4.1.4756.20.500.20.1.317 | ColumnnidPort3LACPParnterSysIDstsLocal | read-only | current | NID Series card Port3 LACP status: Parnter System ID |
| 1.3.6.1.4.1.4756.20.500.20.1.318 | ColumnnidPort3LACPParnterPortstsLocal | read-only | current | NID Series card Port3 LACP status: Parnter Port Status |
| 1.3.6.1.4.1.4756.20.500.20.1.319 | ColumnnidPort3LACPParnterProistsLocal | read-only | current | NID Series card Port3 LACP status: Parnter Priority |
| 1.3.6.1.4.1.4756.20.500.20.1.320 | ColumnnidPort4LACPstsLocal | read-only | current | NID Series card Port4 LACP status: 0: No 1: Yes 2: Standby |
| 1.3.6.1.4.1.4756.20.500.20.1.321 | ColumnnidPort4LACPKEYstsLocal | read-only | current | NID Series card Port4 LACP status: Key |
| 1.3.6.1.4.1.4756.20.500.20.1.322 | ColumnnidPort4LACPAggrIDstsLocal | read-only | current | NID Series card Port4 LACP status: Aggr ID |
| 1.3.6.1.4.1.4756.20.500.20.1.323 | ColumnnidPort4LACPParnterSysIDstsLocal | read-only | current | NID Series card Port4 LACP status: Parnter System ID |
| 1.3.6.1.4.1.4756.20.500.20.1.324 | ColumnnidPort4LACPParnterPortstsLocal | read-only | current | NID Series card Port4 LACP status: Parnter Port Status |
| 1.3.6.1.4.1.4756.20.500.20.1.325 | ColumnnidPort4LACPParnterProistsLocal | read-only | current | NID Series card Port4 LACP status: Parnter Priority |
| 1.3.6.1.4.1.4756.20.500.20.1.326 | ColumnnidPort5LACPstsLocal | read-only | current | NID Series card Port5 LACP status: 0: No 1: Yes 2: Standby |
| 1.3.6.1.4.1.4756.20.500.20.1.327 | ColumnnidPort5LACPKEYstsLocal | read-only | current | NID Series card Port5 LACP status: Key |
| 1.3.6.1.4.1.4756.20.500.20.1.328 | ColumnnidPort5LACPAggrIDstsLocal | read-only | current | NID Series card Port5 LACP status: Aggr ID |
| 1.3.6.1.4.1.4756.20.500.20.1.329 | ColumnnidPort5LACPParnterSysIDstsLocal | read-only | current | NID Series card Port5 LACP status: Parnter System ID |
| 1.3.6.1.4.1.4756.20.500.20.1.330 | ColumnnidPort5LACPParnterPortstsLocal | read-only | current | NID Series card Port5 LACP status: Parnter Port Status |
| 1.3.6.1.4.1.4756.20.500.20.1.331 | ColumnnidPort5LACPParnterProistsLocal | read-only | current | NID Series card Port5 LACP status: Parnter Priority |
| 1.3.6.1.4.1.4756.20.500.20.1.332 | ColumnnidPort6LACPstsLocal | read-only | current | NID Series card Port6 LACP status: 0: No 1: Yes 2: Standby |
| 1.3.6.1.4.1.4756.20.500.20.1.333 | ColumnnidPort6LACPKEYstsLocal | read-only | current | NID Series card Port6 LACP status: Key |
| 1.3.6.1.4.1.4756.20.500.20.1.334 | ColumnnidPort6LACPAggrIDstsLocal | read-only | current | NID Series card Port6 LACP status: Aggr ID |
| 1.3.6.1.4.1.4756.20.500.20.1.335 | ColumnnidPort6LACPParnterSysIDstsLocal | read-only | current | NID Series card Port6 LACP status: Parnter System ID |
| 1.3.6.1.4.1.4756.20.500.20.1.336 | ColumnnidPort6LACPParnterPortstsLocal | read-only | current | NID Series card Port6 LACP status: Parnter Port Status |
| 1.3.6.1.4.1.4756.20.500.20.1.337 | ColumnnidPort6LACPParnterProistsLocal | read-only | current | NID Series card Port6 LACP status: Parnter Priority |
| 1.3.6.1.4.1.4756.20.500.20.1.338 | ColumnnidPort7LACPstsLocal | read-only | current | NID Series card Port7 LACP status: 0: No 1: Yes 2: Standby |
| 1.3.6.1.4.1.4756.20.500.20.1.339 | ColumnnidPort7LACPKEYstsLocal | read-only | current | NID Series card Port7 LACP status: Key |
| 1.3.6.1.4.1.4756.20.500.20.1.340 | ColumnnidPort7LACPAggrIDstsLocal | read-only | current | NID Series card Port7 LACP status: Aggr ID |
| 1.3.6.1.4.1.4756.20.500.20.1.341 | ColumnnidPort7LACPParnterSysIDstsLocal | read-only | current | NID Series card Port7 LACP status: Parnter System ID |
| 1.3.6.1.4.1.4756.20.500.20.1.342 | ColumnnidPort7LACPParnterPortstsLocal | read-only | current | NID Series card Port7 LACP status: Parnter Port Status |
| 1.3.6.1.4.1.4756.20.500.20.1.343 | ColumnnidPort7LACPParnterProistsLocal | read-only | current | NID Series card Port7 LACP status: Parnter Priority |
| 1.3.6.1.4.1.4756.20.500.20.1.344 | ColumnnidPort8LACPstsLocal | read-only | current | NID Series card Port8 LACP status: 0: No 1: Yes 2: Standby |
| 1.3.6.1.4.1.4756.20.500.20.1.345 | ColumnnidPort8LACPKEYstsLocal | read-only | current | NID Series card Port8 LACP status: Key |
| 1.3.6.1.4.1.4756.20.500.20.1.346 | ColumnnidPort8LACPAggrIDstsLocal | read-only | current | NID Series card Port8 LACP status: Aggr ID |
| 1.3.6.1.4.1.4756.20.500.20.1.347 | ColumnnidPort8LACPParnterSysIDstsLocal | read-only | current | NID Series card Port8 LACP status: Parnter System ID |
| 1.3.6.1.4.1.4756.20.500.20.1.348 | ColumnnidPort8LACPParnterPortstsLocal | read-only | current | NID Series card Port8 LACP status: Parnter Port Status |
| 1.3.6.1.4.1.4756.20.500.20.1.349 | ColumnnidPort8LACPParnterProistsLocal | read-only | current | NID Series card Port8 LACP status: Parnter Priority |
| 1.3.6.1.4.1.4756.20.500.20.1.350 | ColumnnidOAMPort1EnableLocal | read-write | current | NID Series card Port1 OAM: 0: Off 1: On |
| 1.3.6.1.4.1.4756.20.500.20.1.351 | ColumnnidOAMPort1ModeLocal | read-write | current | NID Series card Port1 OAM: 0: Passive 1: Active |
| 1.3.6.1.4.1.4756.20.500.20.1.352 | ColumnnidOAMPort1LoopBackLocal | read-write | current | NID Series card Port1 OAM LoopBack: 0: Off 1: On |
| 1.3.6.1.4.1.4756.20.500.20.1.353 | ColumnnidOAMPort1LinkMonitorLocal | read-write | current | NID Series card Port1 OAM Link Monitor: 0: Off 1: On |
| 1.3.6.1.4.1.4756.20.500.20.1.354 | ColumnnidOAMPort1MIBRetrievalLocal | read-write | current | NID Series card Port1 OAM MIB Retrieval: 0: Off 1: On |
| 1.3.6.1.4.1.4756.20.500.20.1.355 | ColumnnidOAMPort1LoopBackOPLocal | read-write | current | NID Series card Port1 OAM LoopBack operation: 0: Off 1: On |
| 1.3.6.1.4.1.4756.20.500.20.1.356 | ColumnnidOAMPort2EnableLocal | read-write | current | NID Series card Port2 OAM: 0: Off 1: On |
| 1.3.6.1.4.1.4756.20.500.20.1.357 | ColumnnidOAMPort2ModeLocal | read-write | current | NID Series card Port2 OAM: 0: Passive 1: Active |
| 1.3.6.1.4.1.4756.20.500.20.1.358 | ColumnnidOAMPort2LoopBackLocal | read-write | current | NID Series card Port2 OAM LoopBack: 0: Off 1: On |
| 1.3.6.1.4.1.4756.20.500.20.1.359 | ColumnnidOAMPort2LinkMonitorLocal | read-write | current | NID Series card Port2 OAM Link Monitor: 0: Off 1: On |
| 1.3.6.1.4.1.4756.20.500.20.1.360 | ColumnnidOAMPort2MIBRetrievalLocal | read-write | current | NID Series card Port2 OAM MIB Retrieval: 0: Off 1: On |
| 1.3.6.1.4.1.4756.20.500.20.1.361 | ColumnnidOAMPort2LoopBackOPLocal | read-write | current | NID Series card Port2 OAM LoopBack operation: 0: Off 1: On |
| 1.3.6.1.4.1.4756.20.500.20.1.362 | ColumnnidOAMPort3EnableLocal | read-write | current | NID Series card Port3 OAM: 0: Off 1: On |
| 1.3.6.1.4.1.4756.20.500.20.1.363 | ColumnnidOAMPort3ModeLocal | read-write | current | NID Series card Port3 OAM: 0: Passive 1: Active |
| 1.3.6.1.4.1.4756.20.500.20.1.364 | ColumnnidOAMPort3LoopBackLocal | read-write | current | NID Series card Port3 OAM: 0: Off 1: On |
| 1.3.6.1.4.1.4756.20.500.20.1.365 | ColumnnidOAMPort3LinkMonitorLocal | read-write | current | NID Series card Port3 OAM Link Monitor: 0: Off 1: On |
| 1.3.6.1.4.1.4756.20.500.20.1.366 | ColumnnidOAMPort3MIBRetrievalLocal | read-write | current | NID Series card Port3 OAM MIB Retrieval: 0: Off 1: On |
| 1.3.6.1.4.1.4756.20.500.20.1.367 | ColumnnidOAMPort3LoopBackOPLocal | read-write | current | NID Series card Port3 OAM LoopBack operation: 0: Disable 1: Enable |
| 1.3.6.1.4.1.4756.20.500.20.1.368 | ColumnnidOAMPort4EnableLocal | read-write | current | NID Series card Port4 OAM: 0: Off 1: On |
| 1.3.6.1.4.1.4756.20.500.20.1.369 | ColumnnidOAMPort4ModeLocal | read-write | current | NID Series card Port4 OAM: 0: Passive 1: Active |
| 1.3.6.1.4.1.4756.20.500.20.1.370 | ColumnnidOAMPort4LoopBackLocal | read-write | current | NID Series card Port4 OAM: 0: Off 1: On |
| 1.3.6.1.4.1.4756.20.500.20.1.371 | ColumnnidOAMPort4LinkMonitorLocal | read-write | current | NID Series card Port4 OAM Link Monitor: 0: Off 1: On |
| 1.3.6.1.4.1.4756.20.500.20.1.372 | ColumnnidOAMPort4MIBRetrievalLocal | read-write | current | NID Series card Port4 OAM MIB Retrieval: 0: Off 1: On |
| 1.3.6.1.4.1.4756.20.500.20.1.373 | ColumnnidOAMPort4LoopBackOPLocal | read-write | current | NID Series card Port4 OAM LoopBack operation: 0: On 1: Off |
| 1.3.6.1.4.1.4756.20.500.20.1.374 | ColumnnidOAMPort5EnableLocal | read-write | current | NID Series card Port5 OAM: 0: Off 1: On |
| 1.3.6.1.4.1.4756.20.500.20.1.375 | ColumnnidOAMPort5ModeLocal | read-write | current | NID Series card Port5 OAM: 0: Passive 1: Active |
| 1.3.6.1.4.1.4756.20.500.20.1.376 | ColumnnidOAMPort5LoopBackLocal | read-write | current | NID Series card Port5 OAM: 0: Off 1: On |
| 1.3.6.1.4.1.4756.20.500.20.1.377 | ColumnnidOAMPort5LinkMonitorLocal | read-write | current | NID Series card Port5 OAM Link Monitor: 0: Off 1: On |
| 1.3.6.1.4.1.4756.20.500.20.1.378 | ColumnnidOAMPort5MIBRetrievalLocal | read-write | current | NID Series card Port5 OAM MIB Retrieval: 0: Off 1: On |
| 1.3.6.1.4.1.4756.20.500.20.1.379 | ColumnnidOAMPort5LoopBackOPLocal | read-write | current | NID Series card Port5 OAM LoopBack operation: 0: On 1: Off |
| 1.3.6.1.4.1.4756.20.500.20.1.380 | ColumnnidOAMPort6EnableLocal | read-write | current | NID Series card Port6 OAM: 0: Off 1: On |
| 1.3.6.1.4.1.4756.20.500.20.1.381 | ColumnnidOAMPort6ModeLocal | read-write | current | NID Series card Port6 OAM: 0: Passive 1: Active |
| 1.3.6.1.4.1.4756.20.500.20.1.382 | ColumnnidOAMPort6LoopBackLocal | read-write | current | NID Series card Port6 OAM: 0: Off 1: On |
| 1.3.6.1.4.1.4756.20.500.20.1.383 | ColumnnidOAMPort6LinkMonitorLocal | read-write | current | NID Series card Port6 OAM Link Monitor: 0: Off 1: On |
| 1.3.6.1.4.1.4756.20.500.20.1.384 | ColumnnidOAMPort6MIBRetrievalLocal | read-write | current | NID Series card Port6 OAM MIB Retrieval: 0: Off 1: On |
| 1.3.6.1.4.1.4756.20.500.20.1.385 | ColumnnidOAMPort6LoopBackOPLocal | read-write | current | NID Series card Port6 OAM LoopBack operation: 0: On 1: Off |
| 1.3.6.1.4.1.4756.20.500.20.1.386 | ColumnnidOAMPort7EnableLocal | read-write | current | NID Series card Port7 OAM: 0: Off 1: On |
| 1.3.6.1.4.1.4756.20.500.20.1.387 | ColumnnidOAMPort7ModeLocal | read-write | current | NID Series card Port7 OAM: 0: Passive 1: Active |
| 1.3.6.1.4.1.4756.20.500.20.1.388 | ColumnnidOAMPort7LoopBackLocal | read-write | current | NID Series card Port7 OAM: 0: Off 1: On |
| 1.3.6.1.4.1.4756.20.500.20.1.389 | ColumnnidOAMPort7LinkMonitorLocal | read-write | current | NID Series card Port7 OAM Link Monitor: 0: Off 1: On |
| 1.3.6.1.4.1.4756.20.500.20.1.390 | ColumnnidOAMPort7MIBRetrievalLocal | read-write | current | NID Series card Port7 OAM MIB Retrieval: 0: Off 1: On |
| 1.3.6.1.4.1.4756.20.500.20.1.391 | ColumnnidOAMPort7LoopBackOPLocal | read-write | current | NID Series card Port7 OAM LoopBack operation: 0: On 1: Off |
| 1.3.6.1.4.1.4756.20.500.20.1.392 | ColumnnidOAMPort8EnableLocal | read-write | current | NID Series card Port8 OAM: 0: Off 1: On |
| 1.3.6.1.4.1.4756.20.500.20.1.393 | ColumnnidOAMPort8ModeLocal | read-write | current | NID Series card Port8 OAM: 0: Passive 1: Active |
| 1.3.6.1.4.1.4756.20.500.20.1.394 | ColumnnidOAMPort8LoopBackLocal | read-write | current | NID Series card Port8 OAM: 0: Off 1: On |
| 1.3.6.1.4.1.4756.20.500.20.1.395 | ColumnnidOAMPort8LinkMonitorLocal | read-write | current | NID Series card Port8 OAM Link Monitor: 0: Off 1: On |
| 1.3.6.1.4.1.4756.20.500.20.1.396 | ColumnnidOAMPort8MIBRetrievalLocal | read-write | current | NID Series card Port8 OAM MIB Retrieval: 0: Off 1: On |
| 1.3.6.1.4.1.4756.20.500.20.1.397 | ColumnnidOAMPort8LoopBackOPLocal | read-write | current | NID Series card Port8 OAM LoopBack operation: 0: On 1: Off |
| 1.3.6.1.4.1.4756.20.500.20.1.398 | ColumnnidPort1EFEErrorWindowLocal | read-write | current | NID Series card Port1 Link Event Configuration: Error Frame Event - Error Window |
| 1.3.6.1.4.1.4756.20.500.20.1.399 | ColumnnidPort1EFEErrorThresholdLocal | read-write | current | NID Series card Port1 Link Event Configuration: Error Frame Event - Error Threshold |
| 1.3.6.1.4.1.4756.20.500.20.1.400 | ColumnnidPort1SPEEErrorWindowLocal | read-write | current | NID Series card Port1 Link Event Configuration: Symbol Period Error Event - Error Window |
| 1.3.6.1.4.1.4756.20.500.20.1.401 | ColumnnidPort1SPEEErrorThresholdLocal | read-write | current | NID Series card Port1 Link Event Configuration: Symbol Period Error Event - Error Threshold |
| 1.3.6.1.4.1.4756.20.500.20.1.402 | ColumnnidPort1SSEErrorWindowLocal | read-write | current | NID Series card Port1 Link Event Configuration: Seconds Summary Event - Error Window |
| 1.3.6.1.4.1.4756.20.500.20.1.403 | ColumnnidPort1SSEErrorThresholdLocal | read-write | current | NID Series card Port1 Link Event Configuration: Seconds Summary Event - Error Threshold |
| 1.3.6.1.4.1.4756.20.500.20.1.404 | ColumnnidPort2EFEErrorWindowLocal | read-write | current | NID Series card Port2 Link Event Configuration: Error Frame Event - Error Window |
| 1.3.6.1.4.1.4756.20.500.20.1.405 | ColumnnidPort2EFEErrorThresholdLocal | read-write | current | NID Series card Port2 Link Event Configuration: Error Frame Event - Error Threshold |
| 1.3.6.1.4.1.4756.20.500.20.1.406 | ColumnnidPort2SPEEErrorWindowLocal | read-write | current | NID Series card Port2 Link Event Configuration: Symbol Period Error Event - Error Window |
| 1.3.6.1.4.1.4756.20.500.20.1.407 | ColumnnidPort2SPEEErrorThresholdLocal | read-write | current | NID Series card Port2 Link Event Configuration: Symbol Period Error Event - Error Threshold |
| 1.3.6.1.4.1.4756.20.500.20.1.408 | ColumnnidPort2SSEErrorWindowLocal | read-write | current | NID Series card Port2 Link Event Configuration: Seconds Summary Event - Error Window |
| 1.3.6.1.4.1.4756.20.500.20.1.409 | ColumnnidPort2SSEErrorThresholdLocal | read-write | current | NID Series card Port2 Link Event Configuration: Seconds Summary Event - Error Threshold |
| 1.3.6.1.4.1.4756.20.500.20.1.410 | ColumnnidPort3EFEErrorWindowLocal | read-write | current | NID Series card Port3 Link Event Configuration: Error Frame Event - Error Window |
| 1.3.6.1.4.1.4756.20.500.20.1.411 | ColumnnidPort3EFEErrorThresholdLocal | read-write | current | NID Series card Port3 Link Event Configuration: Error Frame Event - Error Threshold |
| 1.3.6.1.4.1.4756.20.500.20.1.412 | ColumnnidPort3SPEEErrorWindowLocal | read-write | current | NID Series card Port3 Link Event Configuration: Symbol Period Error Event - Error Window |
| 1.3.6.1.4.1.4756.20.500.20.1.413 | ColumnnidPort3SPEEErrorThresholdLocal | read-write | current | NID Series card Port3 Link Event Configuration: Symbol Period Error Event - Error Threshold |
| 1.3.6.1.4.1.4756.20.500.20.1.414 | ColumnnidPort3SSEErrorWindowLocal | read-write | current | NID Series card Port3 Link Event Configuration: Seconds Summary Event - Error Window |
| 1.3.6.1.4.1.4756.20.500.20.1.415 | ColumnnidPort3SSEErrorThresholdLocal | read-write | current | NID Series card Port3 Link Event Configuration: Seconds Summary Event - Error Threshold |
| 1.3.6.1.4.1.4756.20.500.20.1.416 | ColumnnidPort4EFEErrorWindowLocal | read-write | current | NID Series card Port4 Link Event Configuration: Error Frame Event - Error Window |
| 1.3.6.1.4.1.4756.20.500.20.1.417 | ColumnnidPort4EFEErrorThresholdLocal | read-write | current | NID Series card Port4 Link Event Configuration: Error Frame Event - Error Threshold |
| 1.3.6.1.4.1.4756.20.500.20.1.418 | ColumnnidPort4SPEEErrorWindowLocal | read-write | current | NID Series card Port4 Link Event Configuration: Symbol Period Error Event - Error Window |
| 1.3.6.1.4.1.4756.20.500.20.1.419 | ColumnnidPort4SPEEErrorThresholdLocal | read-write | current | NID Series card Port4 Link Event Configuration: Symbol Period Error Event - Error Threshold |
| 1.3.6.1.4.1.4756.20.500.20.1.420 | ColumnnidPort4SSEErrorWindowLocal | read-write | current | NID Series card Port4 Link Event Configuration: Seconds Summary Event - Error Window |
| 1.3.6.1.4.1.4756.20.500.20.1.421 | ColumnnidPort4SSEErrorThresholdLocal | read-write | current | NID Series card Port4 Link Event Configuration: Seconds Summary Event - Error Threshold |
| 1.3.6.1.4.1.4756.20.500.20.1.422 | ColumnnidPort5EFEErrorWindowLocal | read-write | current | NID Series card Port5 Link Event Configuration: Error Frame Event - Error Window |
| 1.3.6.1.4.1.4756.20.500.20.1.423 | ColumnnidPort5EFEErrorThresholdLocal | read-write | current | NID Series card Port5 Link Event Configuration: Error Frame Event - Error Threshold |
| 1.3.6.1.4.1.4756.20.500.20.1.424 | ColumnnidPort5SPEEErrorWindowLocal | read-write | current | NID Series card Port5 Link Event Configuration: Symbol Period Error Event - Error Window |
| 1.3.6.1.4.1.4756.20.500.20.1.425 | ColumnnidPort5SPEEErrorThresholdLocal | read-write | current | NID Series card Port5 Link Event Configuration: Symbol Period Error Event - Error Threshold |
| 1.3.6.1.4.1.4756.20.500.20.1.426 | ColumnnidPort5SSEErrorWindowLocal | read-write | current | NID Series card Port5 Link Event Configuration: Seconds Summary Event - Error Window |
| 1.3.6.1.4.1.4756.20.500.20.1.427 | ColumnnidPort5SSEErrorThresholdLocal | read-write | current | NID Series card Port5 Link Event Configuration: Seconds Summary Event - Error Threshold |
| 1.3.6.1.4.1.4756.20.500.20.1.428 | ColumnnidPort6EFEErrorWindowLocal | read-write | current | NID Series card Port6 Link Event Configuration: Error Frame Event - Error Window |
| 1.3.6.1.4.1.4756.20.500.20.1.429 | ColumnnidPort6EFEErrorThresholdLocal | read-write | current | NID Series card Port6 Link Event Configuration: Error Frame Event - Error Threshold |
| 1.3.6.1.4.1.4756.20.500.20.1.430 | ColumnnidPort6SPEEErrorWindowLocal | read-write | current | NID Series card Port6 Link Event Configuration: Symbol Period Error Event - Error Window |
| 1.3.6.1.4.1.4756.20.500.20.1.431 | ColumnnidPort6SPEEErrorThresholdLocal | read-write | current | NID Series card Port6 Link Event Configuration: Symbol Period Error Event - Error Threshold |
| 1.3.6.1.4.1.4756.20.500.20.1.432 | ColumnnidPort6SSEErrorWindowLocal | read-write | current | NID Series card Port6 Link Event Configuration: Seconds Summary Event - Error Window |
| 1.3.6.1.4.1.4756.20.500.20.1.433 | ColumnnidPort6SSEErrorThresholdLocal | read-write | current | NID Series card Port6 Link Event Configuration: Seconds Summary Event - Error Threshold |
| 1.3.6.1.4.1.4756.20.500.20.1.434 | ColumnnidPort7EFEErrorWindowLocal | read-write | current | NID Series card Port7 Link Event Configuration: Error Frame Event - Error Window |
| 1.3.6.1.4.1.4756.20.500.20.1.435 | ColumnnidPort7EFEErrorThresholdLocal | read-write | current | NID Series card Port7 Link Event Configuration: Error Frame Event - Error Threshold |
| 1.3.6.1.4.1.4756.20.500.20.1.436 | ColumnnidPort7SPEEErrorWindowLocal | read-write | current | NID Series card Port7 Link Event Configuration: Symbol Period Error Event - Error Window |
| 1.3.6.1.4.1.4756.20.500.20.1.437 | ColumnnidPort7SPEEErrorThresholdLocal | read-write | current | NID Series card Port7 Link Event Configuration: Symbol Period Error Event - Error Threshold |
| 1.3.6.1.4.1.4756.20.500.20.1.438 | ColumnnidPort7SSEErrorWindowLocal | read-write | current | NID Series card Port7 Link Event Configuration: Seconds Summary Event - Error Window |
| 1.3.6.1.4.1.4756.20.500.20.1.439 | ColumnnidPort7SSEErrorThresholdLocal | read-write | current | NID Series card Port7 Link Event Configuration: Seconds Summary Event - Error Threshold |
| 1.3.6.1.4.1.4756.20.500.20.1.440 | ColumnnidPort8EFEErrorWindowLocal | read-write | current | NID Series card Port8 Link Event Configuration: Error Frame Event - Error Window |
| 1.3.6.1.4.1.4756.20.500.20.1.441 | ColumnnidPort8EFEErrorThresholdLocal | read-write | current | NID Series card Port8 Link Event Configuration: Error Frame Event - Error Threshold |
| 1.3.6.1.4.1.4756.20.500.20.1.442 | ColumnnidPort8SPEEErrorWindowLocal | read-write | current | NID Series card Port8 Link Event Configuration: Symbol Period Error Event - Error Window |
| 1.3.6.1.4.1.4756.20.500.20.1.443 | ColumnnidPort8SPEEErrorThresholdLocal | read-write | current | NID Series card Port8 Link Event Configuration: Symbol Period Error Event - Error Threshold |
| 1.3.6.1.4.1.4756.20.500.20.1.444 | ColumnnidPort8SSEErrorWindowLocal | read-write | current | NID Series card Port8 Link Event Configuration: Seconds Summary Event - Error Window |
| 1.3.6.1.4.1.4756.20.500.20.1.445 | ColumnnidPort8SSEErrorThresholdLocal | read-write | current | NID Series card Port8 Link Event Configuration: Seconds Summary Event - Error Threshold |
| 1.3.6.1.4.1.4756.20.500.20.1.446 | ColumnnidPort1RxOAMInfoPDULocal | read-only | current | NID Series card Port1 Detailed Link OAM Statistics: Rx OAM Information PDU's |
| 1.3.6.1.4.1.4756.20.500.20.1.447 | ColumnnidPort1RxUniqueErrorEventLocal | read-only | current | NID Series card Port1 Detailed Link OAM Statistics: Rx Unique Error Event Notificatio |
| 1.3.6.1.4.1.4756.20.500.20.1.448 | ColumnnidPort1RxDuplicateErrorEventLocal | read-only | current | NID Series card Port1 Detailed Link OAM Statistics: Rx Duplicate Error Event Notification |
| 1.3.6.1.4.1.4756.20.500.20.1.449 | ColumnnidPort1RxLoopBackControlLocal | read-only | current | NID Series card Port1 Detailed Link OAM Statistics: Rx Loopback Control |
| 1.3.6.1.4.1.4756.20.500.20.1.450 | ColumnnidPort1RxVariableRequestLocal | read-only | current | NID Series card Port1 Detailed Link OAM Statistics: Rx Variable Request |
| 1.3.6.1.4.1.4756.20.500.20.1.451 | ColumnnidPort1RxVariableResponseLocal | read-only | current | NID Series card Port1 Detailed Link OAM Statistics: Rx Variable Response |
| 1.3.6.1.4.1.4756.20.500.20.1.452 | ColumnnidPort1RxOrgSpecificPDULocal | read-only | current | NID Series card Port1 Detailed Link OAM Statistics: Rx Org Specific PDU's |
| 1.3.6.1.4.1.4756.20.500.20.1.453 | ColumnnidPort1RxUnsupportedCodesLocal | read-only | current | NID Series card Port1 Detailed Link OAM Statistics: Rx Unsupported Codes |
| 1.3.6.1.4.1.4756.20.500.20.1.454 | ColumnnidPort1RxLinkFaultPDULocal | read-only | current | NID Series card Port1 Detailed Link OAM Statistics: Rx Link Fault PDU's |
| 1.3.6.1.4.1.4756.20.500.20.1.455 | ColumnnidPort1RxDyingGaspLocal | read-only | current | NID Series card Port1 Detailed Link OAM Statistics: Rx Dying Gasp |
| 1.3.6.1.4.1.4756.20.500.20.1.456 | ColumnnidPort1RxCriticalEventPDULocal | read-only | current | NID Series card Port1 Detailed Link OAM Statistics: Rx Dying Gasp |
| 1.3.6.1.4.1.4756.20.500.20.1.457 | ColumnnidPort1TxOAMInfoPDULocal | read-only | current | NID Series card Port1 Detailed Link OAM Statistics: Tx OAM Information PDU's |
| 1.3.6.1.4.1.4756.20.500.20.1.458 | ColumnnidPort1TxUniqueErrorEventLocal | read-only | current | NID Series card Port1 Detailed Link OAM Statistics: Tx Unique Error Event Notificatio |
| 1.3.6.1.4.1.4756.20.500.20.1.459 | ColumnnidPort1TxDuplicateErrorEventLocal | read-only | current | NID Series card Port1 Detailed Link OAM Statistics: Tx Duplicate Error Event Notification |
| 1.3.6.1.4.1.4756.20.500.20.1.460 | ColumnnidPort1TxLoopBackControlLocal | read-only | current | NID Series card Port1 Detailed Link OAM Statistics: Tx Loopback Control |
| 1.3.6.1.4.1.4756.20.500.20.1.461 | ColumnnidPort1TxVariableRequestLocal | read-only | current | NID Series card Port1 Detailed Link OAM Statistics: Tx Variable Request |
| 1.3.6.1.4.1.4756.20.500.20.1.462 | ColumnnidPort1TxVariableResponseLocal | read-only | current | NID Series card Port1 Detailed Link OAM Statistics: Tx Variable Response |
| 1.3.6.1.4.1.4756.20.500.20.1.463 | ColumnnidPort1TxOrgSpecificPDULocal | read-only | current | NID Series card Port1 Detailed Link OAM Statistics: Tx Org Specific PDU's |
| 1.3.6.1.4.1.4756.20.500.20.1.464 | ColumnnidPort1TxUnsupportedCodesLocal | read-only | current | NID Series card Port1 Detailed Link OAM Statistics: Tx Unsupported Codes |
| 1.3.6.1.4.1.4756.20.500.20.1.465 | ColumnnidPort1TxLinkFaultPDULocal | read-only | current | NID Series card Port1 Detailed Link OAM Statistics: Tx Link Fault PDU's |
| 1.3.6.1.4.1.4756.20.500.20.1.466 | ColumnnidPort1TxDyingGaspLocal | read-only | current | NID Series card Port1 Detailed Link OAM Statistics: Tx Dying Gasp |
| 1.3.6.1.4.1.4756.20.500.20.1.467 | ColumnnidPort1TxCriticalEventPDULocal | read-only | current | NID Series card Port1 Detailed Link OAM Statistics: Tx Dying Gasp |
| 1.3.6.1.4.1.4756.20.500.20.1.468 | ColumnnidPort2RxOAMInfoPDULocal | read-only | current | NID Series card Port2 Detailed Link OAM Statistics: Rx OAM Information PDU's |
| 1.3.6.1.4.1.4756.20.500.20.1.469 | ColumnnidPort2RxUniqueErrorEventLocal | read-only | current | NID Series card Port2 Detailed Link OAM Statistics: Rx Unique Error Event Notificatio |
| 1.3.6.1.4.1.4756.20.500.20.1.470 | ColumnnidPort2RxDuplicateErrorEventLocal | read-only | current | NID Series card Port2 Detailed Link OAM Statistics: Rx Duplicate Error Event Notification |
| 1.3.6.1.4.1.4756.20.500.20.1.471 | ColumnnidPort2RxLoopBackControlLocal | read-only | current | NID Series card Port2 Detailed Link OAM Statistics: Rx Loopback Control |
| 1.3.6.1.4.1.4756.20.500.20.1.472 | ColumnnidPort2RxVariableRequestLocal | read-only | current | NID Series card Port2 Detailed Link OAM Statistics: Rx Variable Request |
| 1.3.6.1.4.1.4756.20.500.20.1.473 | ColumnnidPort2RxVariableResponseLocal | read-only | current | NID Series card Port2 Detailed Link OAM Statistics: Rx Variable Response |
| 1.3.6.1.4.1.4756.20.500.20.1.474 | ColumnnidPort2RxOrgSpecificPDULocal | read-only | current | NID Series card Port2 Detailed Link OAM Statistics: Rx Org Specific PDU's |
| 1.3.6.1.4.1.4756.20.500.20.1.475 | ColumnnidPort2RxUnsupportedCodesLocal | read-only | current | NID Series card Port2 Detailed Link OAM Statistics: Rx Unsupported Codes |
| 1.3.6.1.4.1.4756.20.500.20.1.476 | ColumnnidPort2RxLinkFaultPDULocal | read-only | current | NID Series card Port2 Detailed Link OAM Statistics: Rx Link Fault PDU's |
| 1.3.6.1.4.1.4756.20.500.20.1.477 | ColumnnidPort2RxDyingGaspLocal | read-only | current | NID Series card Port2 Detailed Link OAM Statistics: Rx Dying Gasp |
| 1.3.6.1.4.1.4756.20.500.20.1.478 | ColumnnidPort2RxCriticalEventPDULocal | read-only | current | NID Series card Port2 Detailed Link OAM Statistics: Rx Dying Gasp |
| 1.3.6.1.4.1.4756.20.500.20.1.479 | ColumnnidPort2TxOAMInfoPDULocal | read-only | current | NID Series card Port2 Detailed Link OAM Statistics: Tx OAM Information PDU's |
| 1.3.6.1.4.1.4756.20.500.20.1.480 | ColumnnidPort2TxUniqueErrorEventLocal | read-only | current | NID Series card Port2 Detailed Link OAM Statistics: Tx Unique Error Event Notificatio |
| 1.3.6.1.4.1.4756.20.500.20.1.481 | ColumnnidPort2TxDuplicateErrorEventLocal | read-only | current | NID Series card Port2 Detailed Link OAM Statistics: Tx Duplicate Error Event Notification |
| 1.3.6.1.4.1.4756.20.500.20.1.482 | ColumnnidPort2TxLoopBackControlLocal | read-only | current | NID Series card Port2 Detailed Link OAM Statistics: Tx Loopback Control |
| 1.3.6.1.4.1.4756.20.500.20.1.483 | ColumnnidPort2TxVariableRequestLocal | read-only | current | NID Series card Port2 Detailed Link OAM Statistics: Tx Variable Request |
| 1.3.6.1.4.1.4756.20.500.20.1.484 | ColumnnidPort2TxVariableResponseLocal | read-only | current | NID Series card Port2 Detailed Link OAM Statistics: Tx Variable Response |
| 1.3.6.1.4.1.4756.20.500.20.1.485 | ColumnnidPort2TxOrgSpecificPDULocal | read-only | current | NID Series card Port2 Detailed Link OAM Statistics: Tx Org Specific PDU's |
| 1.3.6.1.4.1.4756.20.500.20.1.486 | ColumnnidPort2TxUnsupportedCodesLocal | read-only | current | NID Series card Port2 Detailed Link OAM Statistics: Tx Unsupported Codes |
| 1.3.6.1.4.1.4756.20.500.20.1.487 | ColumnnidPort2TxLinkFaultPDULocal | read-only | current | NID Series card Port2 Detailed Link OAM Statistics: Tx Link Fault PDU's |
| 1.3.6.1.4.1.4756.20.500.20.1.488 | ColumnnidPort2TxDyingGaspLocal | read-only | current | NID Series card Port2 Detailed Link OAM Statistics: Tx Dying Gasp |
| 1.3.6.1.4.1.4756.20.500.20.1.489 | ColumnnidPort2TxCriticalEventPDULocal | read-only | current | NID Series card Port2 Detailed Link OAM Statistics: Tx Dying Gasp |
| 1.3.6.1.4.1.4756.20.500.20.1.490 | ColumnnidPort3RxOAMInfoPDULocal | read-only | current | NID Series card Port3 Detailed Link OAM Statistics: Rx OAM Information PDU's |
| 1.3.6.1.4.1.4756.20.500.20.1.491 | ColumnnidPort3RxUniqueErrorEventLocal | read-only | current | NID Series card Port3 Detailed Link OAM Statistics: Rx Unique Error Event Notificatio |
| 1.3.6.1.4.1.4756.20.500.20.1.492 | ColumnnidPort3RxDuplicateErrorEventLocal | read-only | current | NID Series card Port3 Detailed Link OAM Statistics: Rx Duplicate Error Event Notification |
| 1.3.6.1.4.1.4756.20.500.20.1.493 | ColumnnidPort3RxLoopBackControlLocal | read-only | current | NID Series card Port3 Detailed Link OAM Statistics: Rx Loopback Control |
| 1.3.6.1.4.1.4756.20.500.20.1.494 | ColumnnidPort3RxVariableRequestLocal | read-only | current | NID Series card Port3 Detailed Link OAM Statistics: Rx Variable Request |
| 1.3.6.1.4.1.4756.20.500.20.1.495 | ColumnnidPort3RxVariableResponseLocal | read-only | current | NID Series card Port3 Detailed Link OAM Statistics: Rx Variable Response |
| 1.3.6.1.4.1.4756.20.500.20.1.496 | ColumnnidPort3RxOrgSpecificPDULocal | read-only | current | NID Series card Port3 Detailed Link OAM Statistics: Rx Org Specific PDU's |
| 1.3.6.1.4.1.4756.20.500.20.1.497 | ColumnnidPort3RxUnsupportedCodesLocal | read-only | current | NID Series card Port3 Detailed Link OAM Statistics: Rx Unsupported Codes |
| 1.3.6.1.4.1.4756.20.500.20.1.498 | ColumnnidPort3RxLinkFaultPDULocal | read-only | current | NID Series card Port3 Detailed Link OAM Statistics: Rx Link Fault PDU's |
| 1.3.6.1.4.1.4756.20.500.20.1.499 | ColumnnidPort3RxDyingGaspLocal | read-only | current | NID Series card Port3 Detailed Link OAM Statistics: Rx Dying Gasp |
| 1.3.6.1.4.1.4756.20.500.20.1.500 | ColumnnidPort3RxCriticalEventPDULocal | read-only | current | NID Series card Port3 Detailed Link OAM Statistics: Rx Dying Gasp |
| 1.3.6.1.4.1.4756.20.500.20.1.501 | ColumnnidPort3TxOAMInfoPDULocal | read-only | current | NID Series card Port3 Detailed Link OAM Statistics: Tx OAM Information PDU's |
| 1.3.6.1.4.1.4756.20.500.20.1.502 | ColumnnidPort3TxUniqueErrorEventLocal | read-only | current | NID Series card Port3 Detailed Link OAM Statistics: Tx Unique Error Event Notificatio |
| 1.3.6.1.4.1.4756.20.500.20.1.503 | ColumnnidPort3TxDuplicateErrorEventLocal | read-only | current | NID Series card Port3 Detailed Link OAM Statistics: Tx Duplicate Error Event Notification |
| 1.3.6.1.4.1.4756.20.500.20.1.504 | ColumnnidPort3TxLoopBackControlLocal | read-only | current | NID Series card Port3 Detailed Link OAM Statistics: Tx Loopback Control |
| 1.3.6.1.4.1.4756.20.500.20.1.505 | ColumnnidPort3TxVariableRequestLocal | read-only | current | NID Series card Port3 Detailed Link OAM Statistics: Tx Variable Request |
| 1.3.6.1.4.1.4756.20.500.20.1.506 | ColumnnidPort3TxVariableResponseLocal | read-only | current | NID Series card Port3 Detailed Link OAM Statistics: Tx Variable Response |
| 1.3.6.1.4.1.4756.20.500.20.1.507 | ColumnnidPort3TxOrgSpecificPDULocal | read-only | current | NID Series card Port3 Detailed Link OAM Statistics: Tx Org Specific PDU's |
| 1.3.6.1.4.1.4756.20.500.20.1.508 | ColumnnidPort3TxUnsupportedCodesLocal | read-only | current | NID Series card Port3 Detailed Link OAM Statistics: Tx Unsupported Codes |
| 1.3.6.1.4.1.4756.20.500.20.1.509 | ColumnnidPort3TxLinkFaultPDULocal | read-only | current | NID Series card Port3 Detailed Link OAM Statistics: Tx Link Fault PDU's |
| 1.3.6.1.4.1.4756.20.500.20.1.510 | ColumnnidPort3TxDyingGaspLocal | read-only | current | NID Series card Port3 Detailed Link OAM Statistics: Tx Dying Gasp |
| 1.3.6.1.4.1.4756.20.500.20.1.511 | ColumnnidPort3TxCriticalEventPDULocal | read-only | current | NID Series card Port3 Detailed Link OAM Statistics: Tx Dying Gasp |
| 1.3.6.1.4.1.4756.20.500.20.1.512 | ColumnnidPort4RxOAMInfoPDULocal | read-only | current | NID Series card Port4 Detailed Link OAM Statistics: Rx OAM Information PDU's |
| 1.3.6.1.4.1.4756.20.500.20.1.513 | ColumnnidPort4RxUniqueErrorEventLocal | read-only | current | NID Series card Port4 Detailed Link OAM Statistics: Rx Unique Error Event Notificatio |
| 1.3.6.1.4.1.4756.20.500.20.1.514 | ColumnnidPort4RxDuplicateErrorEventLocal | read-only | current | NID Series card Port4 Detailed Link OAM Statistics: Rx Duplicate Error Event Notification |
| 1.3.6.1.4.1.4756.20.500.20.1.515 | ColumnnidPort4RxLoopBackControlLocal | read-only | current | NID Series card Port4 Detailed Link OAM Statistics: Rx Loopback Control |
| 1.3.6.1.4.1.4756.20.500.20.1.516 | ColumnnidPort4RxVariableRequestLocal | read-only | current | NID Series card Port4 Detailed Link OAM Statistics: Rx Variable Request |
| 1.3.6.1.4.1.4756.20.500.20.1.517 | ColumnnidPort4RxVariableResponseLocal | read-only | current | NID Series card Port4 Detailed Link OAM Statistics: Rx Variable Response |
| 1.3.6.1.4.1.4756.20.500.20.1.518 | ColumnnidPort4RxOrgSpecificPDULocal | read-only | current | NID Series card Port4 Detailed Link OAM Statistics: Rx Org Specific PDU's |
| 1.3.6.1.4.1.4756.20.500.20.1.519 | ColumnnidPort4RxUnsupportedCodesLocal | read-only | current | NID Series card Port4 Detailed Link OAM Statistics: Rx Unsupported Codes |
| 1.3.6.1.4.1.4756.20.500.20.1.520 | ColumnnidPort4RxLinkFaultPDULocal | read-only | current | NID Series card Port4 Detailed Link OAM Statistics: Rx Link Fault PDU's |
| 1.3.6.1.4.1.4756.20.500.20.1.521 | ColumnnidPort4RxDyingGaspLocal | read-only | current | NID Series card Port4 Detailed Link OAM Statistics: Rx Dying Gasp |
| 1.3.6.1.4.1.4756.20.500.20.1.522 | ColumnnidPort4RxCriticalEventPDULocal | read-only | current | NID Series card Port4 Detailed Link OAM Statistics: Rx Dying Gasp |
| 1.3.6.1.4.1.4756.20.500.20.1.523 | ColumnnidPort4TxOAMInfoPDULocal | read-only | current | NID Series card Port4 Detailed Link OAM Statistics: Tx OAM Information PDU's |
| 1.3.6.1.4.1.4756.20.500.20.1.524 | ColumnnidPort4TxUniqueErrorEventLocal | read-only | current | NID Series card Port4 Detailed Link OAM Statistics: Tx Unique Error Event Notificatio |
| 1.3.6.1.4.1.4756.20.500.20.1.525 | ColumnnidPort4TxDuplicateErrorEventLocal | read-only | current | NID Series card Port4 Detailed Link OAM Statistics: Tx Duplicate Error Event Notification |
| 1.3.6.1.4.1.4756.20.500.20.1.526 | ColumnnidPort4TxLoopBackControlLocal | read-only | current | NID Series card Port4 Detailed Link OAM Statistics: Tx Loopback Control |
| 1.3.6.1.4.1.4756.20.500.20.1.527 | ColumnnidPort4TxVariableRequestLocal | read-only | current | NID Series card Port4 Detailed Link OAM Statistics: Tx Variable Request |
| 1.3.6.1.4.1.4756.20.500.20.1.528 | ColumnnidPort4TxVariableResponseLocal | read-only | current | NID Series card Port4 Detailed Link OAM Statistics: Tx Variable Response |
| 1.3.6.1.4.1.4756.20.500.20.1.529 | ColumnnidPort4TxOrgSpecificPDULocal | read-only | current | NID Series card Port4 Detailed Link OAM Statistics: Tx Org Specific PDU's |
| 1.3.6.1.4.1.4756.20.500.20.1.530 | ColumnnidPort4TxUnsupportedCodesLocal | read-only | current | NID Series card Port4 Detailed Link OAM Statistics: Tx Unsupported Codes |
| 1.3.6.1.4.1.4756.20.500.20.1.531 | ColumnnidPort4TxLinkFaultPDULocal | read-only | current | NID Series card Port4 Detailed Link OAM Statistics: Tx Link Fault PDU's |
| 1.3.6.1.4.1.4756.20.500.20.1.532 | ColumnnidPort4TxDyingGaspLocal | read-only | current | NID Series card Port4 Detailed Link OAM Statistics: Tx Dying Gasp |
| 1.3.6.1.4.1.4756.20.500.20.1.533 | ColumnnidPort4TxCriticalEventPDULocal | read-only | current | NID Series card Port4 Detailed Link OAM Statistics: Tx Dying Gasp |
| 1.3.6.1.4.1.4756.20.500.20.1.534 | ColumnnidPort5RxOAMInfoPDULocal | read-only | current | NID Series card Port5 Detailed Link OAM Statistics: Rx OAM Information PDU's |
| 1.3.6.1.4.1.4756.20.500.20.1.535 | ColumnnidPort5RxUniqueErrorEventLocal | read-only | current | NID Series card Port5 Detailed Link OAM Statistics: Rx Unique Error Event Notificatio |
| 1.3.6.1.4.1.4756.20.500.20.1.536 | ColumnnidPort5RxDuplicateErrorEventLocal | read-only | current | NID Series card Port5 Detailed Link OAM Statistics: Rx Duplicate Error Event Notification |
| 1.3.6.1.4.1.4756.20.500.20.1.537 | ColumnnidPort5RxLoopBackControlLocal | read-only | current | NID Series card Port5 Detailed Link OAM Statistics: Rx Loopback Control |
| 1.3.6.1.4.1.4756.20.500.20.1.538 | ColumnnidPort5RxVariableRequestLocal | read-only | current | NID Series card Port5 Detailed Link OAM Statistics: Rx Variable Request |
| 1.3.6.1.4.1.4756.20.500.20.1.539 | ColumnnidPort5RxVariableResponseLocal | read-only | current | NID Series card Port5 Detailed Link OAM Statistics: Rx Variable Response |
| 1.3.6.1.4.1.4756.20.500.20.1.540 | ColumnnidPort5RxOrgSpecificPDULocal | read-only | current | NID Series card Port5 Detailed Link OAM Statistics: Rx Org Specific PDU's |
| 1.3.6.1.4.1.4756.20.500.20.1.541 | ColumnnidPort5RxUnsupportedCodesLocal | read-only | current | NID Series card Port5 Detailed Link OAM Statistics: Rx Unsupported Codes |
| 1.3.6.1.4.1.4756.20.500.20.1.542 | ColumnnidPort5RxLinkFaultPDULocal | read-only | current | NID Series card Port5 Detailed Link OAM Statistics: Rx Link Fault PDU's |
| 1.3.6.1.4.1.4756.20.500.20.1.543 | ColumnnidPort5RxDyingGaspLocal | read-only | current | NID Series card Port5 Detailed Link OAM Statistics: Rx Dying Gasp |
| 1.3.6.1.4.1.4756.20.500.20.1.544 | ColumnnidPort5RxCriticalEventPDULocal | read-only | current | NID Series card Port5 Detailed Link OAM Statistics: Rx Dying Gasp |
| 1.3.6.1.4.1.4756.20.500.20.1.545 | ColumnnidPort5TxOAMInfoPDULocal | read-only | current | NID Series card Port5 Detailed Link OAM Statistics: Tx OAM Information PDU's |
| 1.3.6.1.4.1.4756.20.500.20.1.546 | ColumnnidPort5TxUniqueErrorEventLocal | read-only | current | NID Series card Port5 Detailed Link OAM Statistics: Tx Unique Error Event Notificatio |
| 1.3.6.1.4.1.4756.20.500.20.1.547 | ColumnnidPort5TxDuplicateErrorEventLocal | read-only | current | NID Series card Port5 Detailed Link OAM Statistics: Tx Duplicate Error Event Notification |
| 1.3.6.1.4.1.4756.20.500.20.1.548 | ColumnnidPort5TxLoopBackControlLocal | read-only | current | NID Series card Port5 Detailed Link OAM Statistics: Tx Loopback Control |
| 1.3.6.1.4.1.4756.20.500.20.1.549 | ColumnnidPort5TxVariableRequestLocal | read-only | current | NID Series card Port5 Detailed Link OAM Statistics: Tx Variable Request |
| 1.3.6.1.4.1.4756.20.500.20.1.550 | ColumnnidPort5TxVariableResponseLocal | read-only | current | NID Series card Port5 Detailed Link OAM Statistics: Tx Variable Response |
| 1.3.6.1.4.1.4756.20.500.20.1.551 | ColumnnidPort5TxOrgSpecificPDULocal | read-only | current | NID Series card Port5 Detailed Link OAM Statistics: Tx Org Specific PDU's |
| 1.3.6.1.4.1.4756.20.500.20.1.552 | ColumnnidPort5TxUnsupportedCodesLocal | read-only | current | NID Series card Port5 Detailed Link OAM Statistics: Tx Unsupported Codes |
| 1.3.6.1.4.1.4756.20.500.20.1.553 | ColumnnidPort5TxLinkFaultPDULocal | read-only | current | NID Series card Port5 Detailed Link OAM Statistics: Tx Link Fault PDU's |
| 1.3.6.1.4.1.4756.20.500.20.1.554 | ColumnnidPort5TxDyingGaspLocal | read-only | current | NID Series card Port5 Detailed Link OAM Statistics: Tx Dying Gasp |
| 1.3.6.1.4.1.4756.20.500.20.1.555 | ColumnnidPort5TxCriticalEventPDULocal | read-only | current | NID Series card Port5 Detailed Link OAM Statistics: Tx Dying Gasp |
| 1.3.6.1.4.1.4756.20.500.20.1.556 | ColumnnidPort6RxOAMInfoPDULocal | read-only | current | NID Series card Port6 Detailed Link OAM Statistics: Rx OAM Information PDU's |
| 1.3.6.1.4.1.4756.20.500.20.1.557 | ColumnnidPort6RxUniqueErrorEventLocal | read-only | current | NID Series card Port6 Detailed Link OAM Statistics: Rx Unique Error Event Notificatio |
| 1.3.6.1.4.1.4756.20.500.20.1.558 | ColumnnidPort6RxDuplicateErrorEventLocal | read-only | current | NID Series card Port6 Detailed Link OAM Statistics: Rx Duplicate Error Event Notification |
| 1.3.6.1.4.1.4756.20.500.20.1.559 | ColumnnidPort6RxLoopBackControlLocal | read-only | current | NID Series card Port6 Detailed Link OAM Statistics: Rx Loopback Control |
| 1.3.6.1.4.1.4756.20.500.20.1.560 | ColumnnidPort6RxVariableRequestLocal | read-only | current | NID Series card Port6 Detailed Link OAM Statistics: Rx Variable Request |
| 1.3.6.1.4.1.4756.20.500.20.1.561 | ColumnnidPort6RxVariableResponseLocal | read-only | current | NID Series card Port6 Detailed Link OAM Statistics: Rx Variable Response |
| 1.3.6.1.4.1.4756.20.500.20.1.562 | ColumnnidPort6RxOrgSpecificPDULocal | read-only | current | NID Series card Port6 Detailed Link OAM Statistics: Rx Org Specific PDU's |
| 1.3.6.1.4.1.4756.20.500.20.1.563 | ColumnnidPort6RxUnsupportedCodesLocal | read-only | current | NID Series card Port6 Detailed Link OAM Statistics: Rx Unsupported Codes |
| 1.3.6.1.4.1.4756.20.500.20.1.564 | ColumnnidPort6RxLinkFaultPDULocal | read-only | current | NID Series card Port6 Detailed Link OAM Statistics: Rx Link Fault PDU's |
| 1.3.6.1.4.1.4756.20.500.20.1.565 | ColumnnidPort6RxDyingGaspLocal | read-only | current | NID Series card Port6 Detailed Link OAM Statistics: Rx Dying Gasp |
| 1.3.6.1.4.1.4756.20.500.20.1.566 | ColumnnidPort6RxCriticalEventPDULocal | read-only | current | NID Series card Port6 Detailed Link OAM Statistics: Rx Dying Gasp |
| 1.3.6.1.4.1.4756.20.500.20.1.567 | ColumnnidPort6TxOAMInfoPDULocal | read-only | current | NID Series card Port6 Detailed Link OAM Statistics: Tx OAM Information PDU's |
| 1.3.6.1.4.1.4756.20.500.20.1.568 | ColumnnidPort6TxUniqueErrorEventLocal | read-only | current | NID Series card Port6 Detailed Link OAM Statistics: Tx Unique Error Event Notificatio |
| 1.3.6.1.4.1.4756.20.500.20.1.569 | ColumnnidPort6TxDuplicateErrorEventLocal | read-only | current | NID Series card Port6 Detailed Link OAM Statistics: Tx Duplicate Error Event Notification |
| 1.3.6.1.4.1.4756.20.500.20.1.570 | ColumnnidPort6TxLoopBackControlLocal | read-only | current | NID Series card Port6 Detailed Link OAM Statistics: Tx Loopback Control |
| 1.3.6.1.4.1.4756.20.500.20.1.571 | ColumnnidPort6TxVariableRequestLocal | read-only | current | NID Series card Port6 Detailed Link OAM Statistics: Tx Variable Request |
| 1.3.6.1.4.1.4756.20.500.20.1.572 | ColumnnidPort6TxVariableResponseLocal | read-only | current | NID Series card Port6 Detailed Link OAM Statistics: Tx Variable Response |
| 1.3.6.1.4.1.4756.20.500.20.1.573 | ColumnnidPort6TxOrgSpecificPDULocal | read-only | current | NID Series card Port6 Detailed Link OAM Statistics: Tx Org Specific PDU's |
| 1.3.6.1.4.1.4756.20.500.20.1.574 | ColumnnidPort6TxUnsupportedCodesLocal | read-only | current | NID Series card Port6 Detailed Link OAM Statistics: Tx Unsupported Codes |
| 1.3.6.1.4.1.4756.20.500.20.1.575 | ColumnnidPort6TxLinkFaultPDULocal | read-only | current | NID Series card Port6 Detailed Link OAM Statistics: Tx Link Fault PDU's |
| 1.3.6.1.4.1.4756.20.500.20.1.576 | ColumnnidPort6TxDyingGaspLocal | read-only | current | NID Series card Port6 Detailed Link OAM Statistics: Tx Dying Gasp |
| 1.3.6.1.4.1.4756.20.500.20.1.577 | ColumnnidPort6TxCriticalEventPDULocal | read-only | current | NID Series card Port6 Detailed Link OAM Statistics: Tx Dying Gasp |
| 1.3.6.1.4.1.4756.20.500.20.1.578 | ColumnnidPort7RxOAMInfoPDULocal | read-only | current | NID Series card Port7 Detailed Link OAM Statistics: Rx OAM Information PDU's |
| 1.3.6.1.4.1.4756.20.500.20.1.579 | ColumnnidPort7RxUniqueErrorEventLocal | read-only | current | NID Series card Port7 Detailed Link OAM Statistics: Rx Unique Error Event Notificatio |
| 1.3.6.1.4.1.4756.20.500.20.1.580 | ColumnnidPort7RxDuplicateErrorEventLocal | read-only | current | NID Series card Port7 Detailed Link OAM Statistics: Rx Duplicate Error Event Notification |
| 1.3.6.1.4.1.4756.20.500.20.1.581 | ColumnnidPort7RxLoopBackControlLocal | read-only | current | NID Series card Port7 Detailed Link OAM Statistics: Rx Loopback Control |
| 1.3.6.1.4.1.4756.20.500.20.1.582 | ColumnnidPort7RxVariableRequestLocal | read-only | current | NID Series card Port7 Detailed Link OAM Statistics: Rx Variable Request |
| 1.3.6.1.4.1.4756.20.500.20.1.583 | ColumnnidPort7RxVariableResponseLocal | read-only | current | NID Series card Port7 Detailed Link OAM Statistics: Rx Variable Response |
| 1.3.6.1.4.1.4756.20.500.20.1.584 | ColumnnidPort7RxOrgSpecificPDULocal | read-only | current | NID Series card Port7 Detailed Link OAM Statistics: Rx Org Specific PDU's |
| 1.3.6.1.4.1.4756.20.500.20.1.585 | ColumnnidPort7RxUnsupportedCodesLocal | read-only | current | NID Series card Port7 Detailed Link OAM Statistics: Rx Unsupported Codes |
| 1.3.6.1.4.1.4756.20.500.20.1.586 | ColumnnidPort7RxLinkFaultPDULocal | read-only | current | NID Series card Port7 Detailed Link OAM Statistics: Rx Link Fault PDU's |
| 1.3.6.1.4.1.4756.20.500.20.1.587 | ColumnnidPort7RxDyingGaspLocal | read-only | current | NID Series card Port7 Detailed Link OAM Statistics: Rx Dying Gasp |
| 1.3.6.1.4.1.4756.20.500.20.1.588 | ColumnnidPort7RxCriticalEventPDULocal | read-only | current | NID Series card Port7 Detailed Link OAM Statistics: Rx Dying Gasp |
| 1.3.6.1.4.1.4756.20.500.20.1.589 | ColumnnidPort7TxOAMInfoPDULocal | read-only | current | NID Series card Port7 Detailed Link OAM Statistics: Tx OAM Information PDU's |
| 1.3.6.1.4.1.4756.20.500.20.1.590 | ColumnnidPort7TxUniqueErrorEventLocal | read-only | current | NID Series card Port7 Detailed Link OAM Statistics: Tx Unique Error Event Notificatio |
| 1.3.6.1.4.1.4756.20.500.20.1.591 | ColumnnidPort7TxDuplicateErrorEventLocal | read-only | current | NID Series card Port7 Detailed Link OAM Statistics: Tx Duplicate Error Event Notification |
| 1.3.6.1.4.1.4756.20.500.20.1.592 | ColumnnidPort7TxLoopBackControlLocal | read-only | current | NID Series card Port7 Detailed Link OAM Statistics: Tx Loopback Control |
| 1.3.6.1.4.1.4756.20.500.20.1.593 | ColumnnidPort7TxVariableRequestLocal | read-only | current | NID Series card Port7 Detailed Link OAM Statistics: Tx Variable Request |
| 1.3.6.1.4.1.4756.20.500.20.1.594 | ColumnnidPort7TxVariableResponseLocal | read-only | current | NID Series card Port7 Detailed Link OAM Statistics: Tx Variable Response |
| 1.3.6.1.4.1.4756.20.500.20.1.595 | ColumnnidPort7TxOrgSpecificPDULocal | read-only | current | NID Series card Port7 Detailed Link OAM Statistics: Tx Org Specific PDU's |
| 1.3.6.1.4.1.4756.20.500.20.1.596 | ColumnnidPort7TxUnsupportedCodesLocal | read-only | current | NID Series card Port7 Detailed Link OAM Statistics: Tx Unsupported Codes |
| 1.3.6.1.4.1.4756.20.500.20.1.597 | ColumnnidPort7TxLinkFaultPDULocal | read-only | current | NID Series card Port7 Detailed Link OAM Statistics: Tx Link Fault PDU's |
| 1.3.6.1.4.1.4756.20.500.20.1.598 | ColumnnidPort7TxDyingGaspLocal | read-only | current | NID Series card Port7 Detailed Link OAM Statistics: Tx Dying Gasp |
| 1.3.6.1.4.1.4756.20.500.20.1.599 | ColumnnidPort7TxCriticalEventPDULocal | read-only | current | NID Series card Port7 Detailed Link OAM Statistics: Tx Dying Gasp |
| 1.3.6.1.4.1.4756.20.500.20.1.600 | ColumnnidPort8RxOAMInfoPDULocal | read-only | current | NID Series card Port8 Detailed Link OAM Statistics: Rx OAM Information PDU's |
| 1.3.6.1.4.1.4756.20.500.20.1.601 | ColumnnidPort8RxUniqueErrorEventLocal | read-only | current | NID Series card Port8 Detailed Link OAM Statistics: Rx Unique Error Event Notificatio |
| 1.3.6.1.4.1.4756.20.500.20.1.602 | ColumnnidPort8RxDuplicateErrorEventLocal | read-only | current | NID Series card Port8 Detailed Link OAM Statistics: Rx Duplicate Error Event Notification |
| 1.3.6.1.4.1.4756.20.500.20.1.603 | ColumnnidPort8RxLoopBackControlLocal | read-only | current | NID Series card Port8 Detailed Link OAM Statistics: Rx Loopback Control |
| 1.3.6.1.4.1.4756.20.500.20.1.604 | ColumnnidPort8RxVariableRequestLocal | read-only | current | NID Series card Port8 Detailed Link OAM Statistics: Rx Variable Request |
| 1.3.6.1.4.1.4756.20.500.20.1.605 | ColumnnidPort8RxVariableResponseLocal | read-only | current | NID Series card Port8 Detailed Link OAM Statistics: Rx Variable Response |
| 1.3.6.1.4.1.4756.20.500.20.1.606 | ColumnnidPort8RxOrgSpecificPDULocal | read-only | current | NID Series card Port8 Detailed Link OAM Statistics: Rx Org Specific PDU's |
| 1.3.6.1.4.1.4756.20.500.20.1.607 | ColumnnidPort8RxUnsupportedCodesLocal | read-only | current | NID Series card Port8 Detailed Link OAM Statistics: Rx Unsupported Codes |
| 1.3.6.1.4.1.4756.20.500.20.1.608 | ColumnnidPort8RxLinkFaultPDULocal | read-only | current | NID Series card Port8 Detailed Link OAM Statistics: Rx Link Fault PDU's |
| 1.3.6.1.4.1.4756.20.500.20.1.609 | ColumnnidPort8RxDyingGaspLocal | read-only | current | NID Series card Port8 Detailed Link OAM Statistics: Rx Dying Gasp |
| 1.3.6.1.4.1.4756.20.500.20.1.610 | ColumnnidPort8RxCriticalEventPDULocal | read-only | current | NID Series card Port8 Detailed Link OAM Statistics: Rx Dying Gasp |
| 1.3.6.1.4.1.4756.20.500.20.1.611 | ColumnnidPort8TxOAMInfoPDULocal | read-only | current | NID Series card Port8 Detailed Link OAM Statistics: Tx OAM Information PDU's |
| 1.3.6.1.4.1.4756.20.500.20.1.612 | ColumnnidPort8TxUniqueErrorEventLocal | read-only | current | NID Series card Port8 Detailed Link OAM Statistics: Tx Unique Error Event Notificatio |
| 1.3.6.1.4.1.4756.20.500.20.1.613 | ColumnnidPort8TxDuplicateErrorEventLocal | read-only | current | NID Series card Port8 Detailed Link OAM Statistics: Tx Duplicate Error Event Notification |
| 1.3.6.1.4.1.4756.20.500.20.1.614 | ColumnnidPort8TxLoopBackControlLocal | read-only | current | NID Series card Port8 Detailed Link OAM Statistics: Tx Loopback Control |
| 1.3.6.1.4.1.4756.20.500.20.1.615 | ColumnnidPort8TxVariableRequestLocal | read-only | current | NID Series card Port8 Detailed Link OAM Statistics: Tx Variable Request |
| 1.3.6.1.4.1.4756.20.500.20.1.616 | ColumnnidPort8TxVariableResponseLocal | read-only | current | NID Series card Port8 Detailed Link OAM Statistics: Tx Variable Response |
| 1.3.6.1.4.1.4756.20.500.20.1.617 | ColumnnidPort8TxOrgSpecificPDULocal | read-only | current | NID Series card Port8 Detailed Link OAM Statistics: Tx Org Specific PDU's |
| 1.3.6.1.4.1.4756.20.500.20.1.618 | ColumnnidPort8TxUnsupportedCodesLocal | read-only | current | NID Series card Port8 Detailed Link OAM Statistics: Tx Unsupported Codes |
| 1.3.6.1.4.1.4756.20.500.20.1.619 | ColumnnidPort8TxLinkFaultPDULocal | read-only | current | NID Series card Port8 Detailed Link OAM Statistics: Tx Link Fault PDU's |
| 1.3.6.1.4.1.4756.20.500.20.1.620 | ColumnnidPort8TxDyingGaspLocal | read-only | current | NID Series card Port8 Detailed Link OAM Statistics: Tx Dying Gasp |
| 1.3.6.1.4.1.4756.20.500.20.1.621 | ColumnnidPort8TxCriticalEventPDULocal | read-only | current | NID Series card Port8 Detailed Link OAM Statistics: Tx Dying Gasp |
| 1.3.6.1.4.1.4756.20.500.20.1.622 | ColumnnidPort1PDUPermisionLocal | read-only | current | NID Series card Detailed Link OAM Status for Port 1: PDU Permission |
| 1.3.6.1.4.1.4756.20.500.20.1.623 | ColumnnidPort1DiscoveryStateLocal | read-only | current | NID Series card Detailed Link OAM Status for Port 1: Discovery State |
| 1.3.6.1.4.1.4756.20.500.20.1.624 | ColumnnidPort1PeerMACAddrLocal | read-only | current | NID Series card Detailed Link OAM Status for Port 1: Discovery State |
| 1.3.6.1.4.1.4756.20.500.20.1.625 | ColumnnidPort1LocalModeLocal | read-only | current | NID Series card Detailed Link OAM Status for Port 1: Local: Mode |
| 1.3.6.1.4.1.4756.20.500.20.1.626 | ColumnnidPort1LocalUnOperationLocal | read-only | current | NID Series card Detailed Link OAM Status for Port 1: Local: Unidirectional Operation Support |
| 1.3.6.1.4.1.4756.20.500.20.1.627 | ColumnnidPort1LocalRemoteLbLocal | read-only | current | NID Series card Detailed Link OAM Status for Port 1: Local: Remote Loopback Support |
| 1.3.6.1.4.1.4756.20.500.20.1.628 | ColumnnidPort1LocalLMLocal | read-only | current | NID Series card Detailed Link OAM Status for Port 1: Local: Link Monitoring Support |
| 1.3.6.1.4.1.4756.20.500.20.1.629 | ColumnnidPort1LocalMIBRetrievalLocal | read-only | current | NID Series card Detailed Link OAM Status for Port 1: Local: MIB Retrieval Support |
| 1.3.6.1.4.1.4756.20.500.20.1.630 | ColumnnidPort1LocalMTUSizeLocal | read-only | current | NID Series card Detailed Link OAM Status for Port 1: Local: MTU Size |
| 1.3.6.1.4.1.4756.20.500.20.1.631 | ColumnnidPort1LocalMultiStateLocal | read-only | current | NID Series card Detailed Link OAM Status for Port 1: Local: Multiplexer State |
| 1.3.6.1.4.1.4756.20.500.20.1.632 | ColumnnidPort1LocalParserStateLocal | read-only | current | NID Series card Detailed Link OAM Status for Port 1: Local: Multiplexer State |
| 1.3.6.1.4.1.4756.20.500.20.1.633 | ColumnnidPort1LocalOUILocal | read-only | current | NID Series card Detailed Link OAM Status for Port 1: Local: Organizational Unique Identification |
| 1.3.6.1.4.1.4756.20.500.20.1.634 | ColumnnidPort1LocalPDURevLocal | read-only | current | NID Series card Detailed Link OAM Status for Port 1: Local: PDU Revision |
| 1.3.6.1.4.1.4756.20.500.20.1.635 | ColumnnidPort1PeerModeLocal | read-only | current | NID Series card Detailed Link OAM Status for Port 1: Peer: Mode |
| 1.3.6.1.4.1.4756.20.500.20.1.636 | ColumnnidPort1PeerUnOperationLocal | read-only | current | NID Series card Detailed Link OAM Status for Port 1: Peer: Unidirectional Operation Support |
| 1.3.6.1.4.1.4756.20.500.20.1.637 | ColumnnidPort1PeerRemoteLbLocal | read-only | current | NID Series card Detailed Link OAM Status for Port 1: Peer: Remote Loopback Support |
| 1.3.6.1.4.1.4756.20.500.20.1.638 | ColumnnidPort1PeerLMLocal | read-only | current | NID Series card Detailed Link OAM Status for Port 1: Peer: Link Monitoring Support |
| 1.3.6.1.4.1.4756.20.500.20.1.639 | ColumnnidPort1PeerMIBRetrievalLocal | read-only | current | NID Series card Detailed Link OAM Status for Port 1: Peer: MIB Retrieval Support |
| 1.3.6.1.4.1.4756.20.500.20.1.640 | ColumnnidPort1PeerMTUSizeLocal | read-only | current | NID Series card Detailed Link OAM Status for Port 1: Peer: MTU Size |
| 1.3.6.1.4.1.4756.20.500.20.1.641 | ColumnnidPort1PeerMultiStateLocal | read-only | current | NID Series card Detailed Link OAM Status for Port 1: Peer: Multiplexer State |
| 1.3.6.1.4.1.4756.20.500.20.1.642 | ColumnnidPort1PeerParserStateLocal | read-only | current | NID Series card Detailed Link OAM Status for Port 1: Peer: Multiplexer State |
| 1.3.6.1.4.1.4756.20.500.20.1.643 | ColumnnidPort1PeerOUILocal | read-only | current | NID Series card Detailed Link OAM Status for Port 1: Peer: Organizational Unique Identification |
| 1.3.6.1.4.1.4756.20.500.20.1.644 | ColumnnidPort1PeerPDURevLocal | read-only | current | NID Series card Detailed Link OAM Status for Port 1: Peer: PDU Revision |
| 1.3.6.1.4.1.4756.20.500.20.1.645 | ColumnnidPort2PDUPermisionLocal | read-only | current | NID Series card Detailed Link OAM Status for Port 2: PDU Permission |
| 1.3.6.1.4.1.4756.20.500.20.1.646 | ColumnnidPort2DiscoveryStateLocal | read-only | current | NID Series card Detailed Link OAM Status for Port 2: Discovery State |
| 1.3.6.1.4.1.4756.20.500.20.1.647 | ColumnnidPort2PeerMACAddrLocal | read-only | current | NID Series card Detailed Link OAM Status for Port 2: Discovery State |
| 1.3.6.1.4.1.4756.20.500.20.1.648 | ColumnnidPort2LocalModeLocal | read-only | current | NID Series card Detailed Link OAM Status for Port 2: Local: Mode |
| 1.3.6.1.4.1.4756.20.500.20.1.649 | ColumnnidPort2LocalUnOperationLocal | read-only | current | NID Series card Detailed Link OAM Status for Port 2: Local: Unidirectional Operation Support |
| 1.3.6.1.4.1.4756.20.500.20.1.650 | ColumnnidPort2LocalRemoteLbLocal | read-only | current | NID Series card Detailed Link OAM Status for Port 2: Local: Remote Loopback Support |
| 1.3.6.1.4.1.4756.20.500.20.1.651 | ColumnnidPort2LocalLMLocal | read-only | current | NID Series card Detailed Link OAM Status for Port 2: Local: Link Monitoring Support |
| 1.3.6.1.4.1.4756.20.500.20.1.652 | ColumnnidPort2LocalMIBRetrievalLocal | read-only | current | NID Series card Detailed Link OAM Status for Port 2: Local: MIB Retrieval Support |
| 1.3.6.1.4.1.4756.20.500.20.1.653 | ColumnnidPort2LocalMTUSizeLocal | read-only | current | NID Series card Detailed Link OAM Status for Port 2: Local: MTU Size |
| 1.3.6.1.4.1.4756.20.500.20.1.654 | ColumnnidPort2LocalMultiStateLocal | read-only | current | NID Series card Detailed Link OAM Status for Port 2: Local: Multiplexer State |
| 1.3.6.1.4.1.4756.20.500.20.1.655 | ColumnnidPort2LocalParserStateLocal | read-only | current | NID Series card Detailed Link OAM Status for Port 2: Local: Multiplexer State |
| 1.3.6.1.4.1.4756.20.500.20.1.656 | ColumnnidPort2LocalOUILocal | read-only | current | NID Series card Detailed Link OAM Status for Port 2: Local: Organizational Unique Identification |
| 1.3.6.1.4.1.4756.20.500.20.1.657 | ColumnnidPort2LocalPDURevLocal | read-only | current | NID Series card Detailed Link OAM Status for Port 2: Local: PDU Revision |
| 1.3.6.1.4.1.4756.20.500.20.1.658 | ColumnnidPort2PeerModeLocal | read-only | current | NID Series card Detailed Link OAM Status for Port 2: Peer: Mode |
| 1.3.6.1.4.1.4756.20.500.20.1.659 | ColumnnidPort2PeerUnOperationLocal | read-only | current | NID Series card Detailed Link OAM Status for Port 2: Peer: Unidirectional Operation Support |
| 1.3.6.1.4.1.4756.20.500.20.1.660 | ColumnnidPort2PeerRemoteLbLocal | read-only | current | NID Series card Detailed Link OAM Status for Port 2: Peer: Remote Loopback Support |
| 1.3.6.1.4.1.4756.20.500.20.1.661 | ColumnnidPort2PeerLMLocal | read-only | current | NID Series card Detailed Link OAM Status for Port 2: Peer: Link Monitoring Support |
| 1.3.6.1.4.1.4756.20.500.20.1.662 | ColumnnidPort2PeerMIBRetrievalLocal | read-only | current | NID Series card Detailed Link OAM Status for Port 2: Peer: MIB Retrieval Support |
| 1.3.6.1.4.1.4756.20.500.20.1.663 | ColumnnidPort2PeerMTUSizeLocal | read-only | current | NID Series card Detailed Link OAM Status for Port 2: Peer: MTU Size |
| 1.3.6.1.4.1.4756.20.500.20.1.664 | ColumnnidPort2PeerMultiStateLocal | read-only | current | NID Series card Detailed Link OAM Status for Port 2: Peer: Multiplexer State |
| 1.3.6.1.4.1.4756.20.500.20.1.665 | ColumnnidPort2PeerParserStateLocal | read-only | current | NID Series card Detailed Link OAM Status for Port 2: Peer: Multiplexer State |
| 1.3.6.1.4.1.4756.20.500.20.1.666 | ColumnnidPort2PeerOUILocal | read-only | current | NID Series card Detailed Link OAM Status for Port 2: Peer: Organizational Unique Identification |
| 1.3.6.1.4.1.4756.20.500.20.1.667 | ColumnnidPort2PeerPDURevLocal | read-only | current | NID Series card Detailed Link OAM Status for Port 2: Peer: PDU Revision |
| 1.3.6.1.4.1.4756.20.500.20.1.668 | ColumnnidPort3PDUPermisionLocal | read-only | current | NID Series card Detailed Link OAM Status for Port 3: PDU Permission |
| 1.3.6.1.4.1.4756.20.500.20.1.669 | ColumnnidPort3DiscoveryStateLocal | read-only | current | NID Series card Detailed Link OAM Status for Port 3: Discovery State |
| 1.3.6.1.4.1.4756.20.500.20.1.670 | ColumnnidPort3PeerMACAddrLocal | read-only | current | NID Series card Detailed Link OAM Status for Port 3: Discovery State |
| 1.3.6.1.4.1.4756.20.500.20.1.671 | ColumnnidPort3LocalModeLocal | read-only | current | NID Series card Detailed Link OAM Status for Port 3: Local: Mode |
| 1.3.6.1.4.1.4756.20.500.20.1.672 | ColumnnidPort3LocalUnOperationLocal | read-only | current | NID Series card Detailed Link OAM Status for Port 3: Local: Unidirectional Operation Support |
| 1.3.6.1.4.1.4756.20.500.20.1.673 | ColumnnidPort3LocalRemoteLbLocal | read-only | current | NID Series card Detailed Link OAM Status for Port 3: Local: Remote Loopback Support |
| 1.3.6.1.4.1.4756.20.500.20.1.674 | ColumnnidPort3LocalLMLocal | read-only | current | NID Series card Detailed Link OAM Status for Port 3: Local: Link Monitoring Support |
| 1.3.6.1.4.1.4756.20.500.20.1.675 | ColumnnidPort3LocalMIBRetrievalLocal | read-only | current | NID Series card Detailed Link OAM Status for Port 3: Local: MIB Retrieval Support |
| 1.3.6.1.4.1.4756.20.500.20.1.676 | ColumnnidPort3LocalMTUSizeLocal | read-only | current | NID Series card Detailed Link OAM Status for Port 3: Local: MTU Size |
| 1.3.6.1.4.1.4756.20.500.20.1.677 | ColumnnidPort3LocalMultiStateLocal | read-only | current | NID Series card Detailed Link OAM Status for Port 3: Local: Multiplexer State |
| 1.3.6.1.4.1.4756.20.500.20.1.678 | ColumnnidPort3LocalParserStateLocal | read-only | current | NID Series card Detailed Link OAM Status for Port 3: Local: Multiplexer State |
| 1.3.6.1.4.1.4756.20.500.20.1.679 | ColumnnidPort3LocalOUILocal | read-only | current | NID Series card Detailed Link OAM Status for Port 3: Local: Organizational Unique Identification |
| 1.3.6.1.4.1.4756.20.500.20.1.680 | ColumnnidPort3LocalPDURevLocal | read-only | current | NID Series card Detailed Link OAM Status for Port 3: Local: PDU Revision |
| 1.3.6.1.4.1.4756.20.500.20.1.681 | ColumnnidPort3PeerModeLocal | read-only | current | NID Series card Detailed Link OAM Status for Port 3: Peer: Mode |
| 1.3.6.1.4.1.4756.20.500.20.1.682 | ColumnnidPort3PeerUnOperationLocal | read-only | current | NID Series card Detailed Link OAM Status for Port 3: Peer: Unidirectional Operation Support |
| 1.3.6.1.4.1.4756.20.500.20.1.683 | ColumnnidPort3PeerRemoteLbLocal | read-only | current | NID Series card Detailed Link OAM Status for Port 3: Peer: Remote Loopback Support |
| 1.3.6.1.4.1.4756.20.500.20.1.684 | ColumnnidPort3PeerLMLocal | read-only | current | NID Series card Detailed Link OAM Status for Port 3: Peer: Link Monitoring Support |
| 1.3.6.1.4.1.4756.20.500.20.1.685 | ColumnnidPort3PeerMIBRetrievalLocal | read-only | current | NID Series card Detailed Link OAM Status for Port 3: Peer: MIB Retrieval Support |
| 1.3.6.1.4.1.4756.20.500.20.1.686 | ColumnnidPort3PeerMTUSizeLocal | read-only | current | NID Series card Detailed Link OAM Status for Port 3: Peer: MTU Size |
| 1.3.6.1.4.1.4756.20.500.20.1.687 | ColumnnidPort3PeerMultiStateLocal | read-only | current | NID Series card Detailed Link OAM Status for Port 3: Peer: Multiplexer State |
| 1.3.6.1.4.1.4756.20.500.20.1.688 | ColumnnidPort3PeerParserStateLocal | read-only | current | NID Series card Detailed Link OAM Status for Port 3: Peer: Multiplexer State |
| 1.3.6.1.4.1.4756.20.500.20.1.689 | ColumnnidPort3PeerOUILocal | read-only | current | NID Series card Detailed Link OAM Status for Port 3: Peer: Organizational Unique Identification |
| 1.3.6.1.4.1.4756.20.500.20.1.690 | ColumnnidPort3PeerPDURevLocal | read-only | current | NID Series card Detailed Link OAM Status for Port 3: Peer: PDU Revision |
| 1.3.6.1.4.1.4756.20.500.20.1.691 | ColumnnidPort4PDUPermisionLocal | read-only | current | NID Series card Detailed Link OAM Status for Port 4: PDU Permission |
| 1.3.6.1.4.1.4756.20.500.20.1.692 | ColumnnidPort4DiscoveryStateLocal | read-only | current | NID Series card Detailed Link OAM Status for Port 4: Discovery State |
| 1.3.6.1.4.1.4756.20.500.20.1.693 | ColumnnidPort4PeerMACAddrLocal | read-only | current | NID Series card Detailed Link OAM Status for Port 4: Discovery State |
| 1.3.6.1.4.1.4756.20.500.20.1.694 | ColumnnidPort4LocalModeLocal | read-only | current | NID Series card Detailed Link OAM Status for Port 4: Local: Mode |
| 1.3.6.1.4.1.4756.20.500.20.1.695 | ColumnnidPort4LocalUnOperationLocal | read-only | current | NID Series card Detailed Link OAM Status for Port 4: Local: Unidirectional Operation Support |
| 1.3.6.1.4.1.4756.20.500.20.1.696 | ColumnnidPort4LocalRemoteLbLocal | read-only | current | NID Series card Detailed Link OAM Status for Port 4: Local: Remote Loopback Support |
| 1.3.6.1.4.1.4756.20.500.20.1.697 | ColumnnidPort4LocalLMLocal | read-only | current | NID Series card Detailed Link OAM Status for Port 4: Local: Link Monitoring Support |
| 1.3.6.1.4.1.4756.20.500.20.1.698 | ColumnnidPort4LocalMIBRetrievalLocal | read-only | current | NID Series card Detailed Link OAM Status for Port 4: Local: MIB Retrieval Support |
| 1.3.6.1.4.1.4756.20.500.20.1.699 | ColumnnidPort4LocalMTUSizeLocal | read-only | current | NID Series card Detailed Link OAM Status for Port 4: Local: MTU Size |
| 1.3.6.1.4.1.4756.20.500.20.1.700 | ColumnnidPort4LocalMultiStateLocal | read-only | current | NID Series card Detailed Link OAM Status for Port 4: Local: Multiplexer State |
| 1.3.6.1.4.1.4756.20.500.20.1.701 | ColumnnidPort4LocalParserStateLocal | read-only | current | NID Series card Detailed Link OAM Status for Port 4: Local: Multiplexer State |
| 1.3.6.1.4.1.4756.20.500.20.1.702 | ColumnnidPort4LocalOUILocal | read-only | current | NID Series card Detailed Link OAM Status for Port 4: Local: Organizational Unique Identification |
| 1.3.6.1.4.1.4756.20.500.20.1.703 | ColumnnidPort4LocalPDURevLocal | read-only | current | NID Series card Detailed Link OAM Status for Port 4: Local: PDU Revision |
| 1.3.6.1.4.1.4756.20.500.20.1.704 | ColumnnidPort4PeerModeLocal | read-only | current | NID Series card Detailed Link OAM Status for Port 4: Peer: Mode |
| 1.3.6.1.4.1.4756.20.500.20.1.705 | ColumnnidPort4PeerUnOperationLocal | read-only | current | NID Series card Detailed Link OAM Status for Port 4: Peer: Unidirectional Operation Support |
| 1.3.6.1.4.1.4756.20.500.20.1.706 | ColumnnidPort4PeerRemoteLbLocal | read-only | current | NID Series card Detailed Link OAM Status for Port 4: Peer: Remote Loopback Support |
| 1.3.6.1.4.1.4756.20.500.20.1.707 | ColumnnidPort4PeerLMLocal | read-only | current | NID Series card Detailed Link OAM Status for Port 4: Peer: Link Monitoring Support |
| 1.3.6.1.4.1.4756.20.500.20.1.708 | ColumnnidPort4PeerMIBRetrievalLocal | read-only | current | NID Series card Detailed Link OAM Status for Port 4: Peer: MIB Retrieval Support |
| 1.3.6.1.4.1.4756.20.500.20.1.709 | ColumnnidPort4PeerMTUSizeLocal | read-only | current | NID Series card Detailed Link OAM Status for Port 4: Peer: MTU Size |
| 1.3.6.1.4.1.4756.20.500.20.1.710 | ColumnnidPort4PeerMultiStateLocal | read-only | current | NID Series card Detailed Link OAM Status for Port 4: Peer: Multiplexer State |
| 1.3.6.1.4.1.4756.20.500.20.1.711 | ColumnnidPort4PeerParserStateLocal | read-only | current | NID Series card Detailed Link OAM Status for Port 4: Peer: Multiplexer State |
| 1.3.6.1.4.1.4756.20.500.20.1.712 | ColumnnidPort4PeerOUILocal | read-only | current | NID Series card Detailed Link OAM Status for Port 4: Peer: Organizational Unique Identification |
| 1.3.6.1.4.1.4756.20.500.20.1.713 | ColumnnidPort4PeerPDURevLocal | read-only | current | NID Series card Detailed Link OAM Status for Port 4: Peer: PDU Revision |
| 1.3.6.1.4.1.4756.20.500.20.1.714 | ColumnnidPort5PDUPermisionLocal | read-only | current | NID Series card Detailed Link OAM Status for Port 5: PDU Permission |
| 1.3.6.1.4.1.4756.20.500.20.1.715 | ColumnnidPort5DiscoveryStateLocal | read-only | current | NID Series card Detailed Link OAM Status for Port 5: Discovery State |
| 1.3.6.1.4.1.4756.20.500.20.1.716 | ColumnnidPort5PeerMACAddrLocal | read-only | current | NID Series card Detailed Link OAM Status for Port 5: Discovery State |
| 1.3.6.1.4.1.4756.20.500.20.1.717 | ColumnnidPort5LocalModeLocal | read-only | current | NID Series card Detailed Link OAM Status for Port 5: Local: Mode |
| 1.3.6.1.4.1.4756.20.500.20.1.718 | ColumnnidPort5LocalUnOperationLocal | read-only | current | NID Series card Detailed Link OAM Status for Port 5: Local: Unidirectional Operation Support |
| 1.3.6.1.4.1.4756.20.500.20.1.719 | ColumnnidPort5LocalRemoteLbLocal | read-only | current | NID Series card Detailed Link OAM Status for Port 5: Local: Remote Loopback Support |
| 1.3.6.1.4.1.4756.20.500.20.1.720 | ColumnnidPort5LocalLMLocal | read-only | current | NID Series card Detailed Link OAM Status for Port 5: Local: Link Monitoring Support |
| 1.3.6.1.4.1.4756.20.500.20.1.721 | ColumnnidPort5LocalMIBRetrievalLocal | read-only | current | NID Series card Detailed Link OAM Status for Port 5: Local: MIB Retrieval Support |
| 1.3.6.1.4.1.4756.20.500.20.1.722 | ColumnnidPort5LocalMTUSizeLocal | read-only | current | NID Series card Detailed Link OAM Status for Port 5: Local: MTU Size |
| 1.3.6.1.4.1.4756.20.500.20.1.723 | ColumnnidPort5LocalMultiStateLocal | read-only | current | NID Series card Detailed Link OAM Status for Port 5: Local: Multiplexer State |
| 1.3.6.1.4.1.4756.20.500.20.1.724 | ColumnnidPort5LocalParserStateLocal | read-only | current | NID Series card Detailed Link OAM Status for Port 5: Local: Multiplexer State |
| 1.3.6.1.4.1.4756.20.500.20.1.725 | ColumnnidPort5LocalOUILocal | read-only | current | NID Series card Detailed Link OAM Status for Port 5: Local: Organizational Unique Identification |
| 1.3.6.1.4.1.4756.20.500.20.1.726 | ColumnnidPort5LocalPDURevLocal | read-only | current | NID Series card Detailed Link OAM Status for Port 5: Local: PDU Revision |
| 1.3.6.1.4.1.4756.20.500.20.1.727 | ColumnnidPort5PeerModeLocal | read-only | current | NID Series card Detailed Link OAM Status for Port 5: Peer: Mode |
| 1.3.6.1.4.1.4756.20.500.20.1.728 | ColumnnidPort5PeerUnOperationLocal | read-only | current | NID Series card Detailed Link OAM Status for Port 5: Peer: Unidirectional Operation Support |
| 1.3.6.1.4.1.4756.20.500.20.1.729 | ColumnnidPort5PeerRemoteLbLocal | read-only | current | NID Series card Detailed Link OAM Status for Port 5: Peer: Remote Loopback Support |
| 1.3.6.1.4.1.4756.20.500.20.1.730 | ColumnnidPort5PeerLMLocal | read-only | current | NID Series card Detailed Link OAM Status for Port 5: Peer: Link Monitoring Support |
| 1.3.6.1.4.1.4756.20.500.20.1.731 | ColumnnidPort5PeerMIBRetrievalLocal | read-only | current | NID Series card Detailed Link OAM Status for Port 5: Peer: MIB Retrieval Support |
| 1.3.6.1.4.1.4756.20.500.20.1.732 | ColumnnidPort5PeerMTUSizeLocal | read-only | current | NID Series card Detailed Link OAM Status for Port 5: Peer: MTU Size |
| 1.3.6.1.4.1.4756.20.500.20.1.733 | ColumnnidPort5PeerMultiStateLocal | read-only | current | NID Series card Detailed Link OAM Status for Port 5: Peer: Multiplexer State |
| 1.3.6.1.4.1.4756.20.500.20.1.734 | ColumnnidPort5PeerParserStateLocal | read-only | current | NID Series card Detailed Link OAM Status for Port 5: Peer: Multiplexer State |
| 1.3.6.1.4.1.4756.20.500.20.1.735 | ColumnnidPort5PeerOUILocal | read-only | current | NID Series card Detailed Link OAM Status for Port 5: Peer: Organizational Unique Identification |
| 1.3.6.1.4.1.4756.20.500.20.1.736 | ColumnnidPort5PeerPDURevLocal | read-only | current | NID Series card Detailed Link OAM Status for Port 5: Peer: PDU Revision |
| 1.3.6.1.4.1.4756.20.500.20.1.737 | ColumnnidPort6PDUPermisionLocal | read-only | current | NID Series card Detailed Link OAM Status for Port 6: PDU Permission |
| 1.3.6.1.4.1.4756.20.500.20.1.738 | ColumnnidPort6DiscoveryStateLocal | read-only | current | NID Series card Detailed Link OAM Status for Port 6: Discovery State |
| 1.3.6.1.4.1.4756.20.500.20.1.739 | ColumnnidPort6PeerMACAddrLocal | read-only | current | NID Series card Detailed Link OAM Status for Port 6: Discovery State |
| 1.3.6.1.4.1.4756.20.500.20.1.740 | ColumnnidPort6LocalModeLocal | read-only | current | NID Series card Detailed Link OAM Status for Port 6: Local: Mode |
| 1.3.6.1.4.1.4756.20.500.20.1.741 | ColumnnidPort6LocalUnOperationLocal | read-only | current | NID Series card Detailed Link OAM Status for Port 6: Local: Unidirectional Operation Support |
| 1.3.6.1.4.1.4756.20.500.20.1.742 | ColumnnidPort6LocalRemoteLbLocal | read-only | current | NID Series card Detailed Link OAM Status for Port 6: Local: Remote Loopback Support |
| 1.3.6.1.4.1.4756.20.500.20.1.743 | ColumnnidPort6LocalLMLocal | read-only | current | NID Series card Detailed Link OAM Status for Port 6: Local: Link Monitoring Support |
| 1.3.6.1.4.1.4756.20.500.20.1.744 | ColumnnidPort6LocalMIBRetrievalLocal | read-only | current | NID Series card Detailed Link OAM Status for Port 6: Local: MIB Retrieval Support |
| 1.3.6.1.4.1.4756.20.500.20.1.745 | ColumnnidPort6LocalMTUSizeLocal | read-only | current | NID Series card Detailed Link OAM Status for Port 6: Local: MTU Size |
| 1.3.6.1.4.1.4756.20.500.20.1.746 | ColumnnidPort6LocalMultiStateLocal | read-only | current | NID Series card Detailed Link OAM Status for Port 6: Local: Multiplexer State |
| 1.3.6.1.4.1.4756.20.500.20.1.747 | ColumnnidPort6LocalParserStateLocal | read-only | current | NID Series card Detailed Link OAM Status for Port 6: Local: Multiplexer State |
| 1.3.6.1.4.1.4756.20.500.20.1.748 | ColumnnidPort6LocalOUILocal | read-only | current | NID Series card Detailed Link OAM Status for Port 6: Local: Organizational Unique Identification |
| 1.3.6.1.4.1.4756.20.500.20.1.749 | ColumnnidPort6LocalPDURevLocal | read-only | current | NID Series card Detailed Link OAM Status for Port 6: Local: PDU Revision |
| 1.3.6.1.4.1.4756.20.500.20.1.750 | ColumnnidPort6PeerModeLocal | read-only | current | NID Series card Detailed Link OAM Status for Port 6: Peer: Mode |
| 1.3.6.1.4.1.4756.20.500.20.1.751 | ColumnnidPort6PeerUnOperationLocal | read-only | current | NID Series card Detailed Link OAM Status for Port 6: Peer: Unidirectional Operation Support |
| 1.3.6.1.4.1.4756.20.500.20.1.752 | ColumnnidPort6PeerRemoteLbLocal | read-only | current | NID Series card Detailed Link OAM Status for Port 6: Peer: Remote Loopback Support |
| 1.3.6.1.4.1.4756.20.500.20.1.753 | ColumnnidPort6PeerLMLocal | read-only | current | NID Series card Detailed Link OAM Status for Port 6: Peer: Link Monitoring Support |
| 1.3.6.1.4.1.4756.20.500.20.1.754 | ColumnnidPort6PeerMIBRetrievalLocal | read-only | current | NID Series card Detailed Link OAM Status for Port 6: Peer: MIB Retrieval Support |
| 1.3.6.1.4.1.4756.20.500.20.1.755 | ColumnnidPort6PeerMTUSizeLocal | read-only | current | NID Series card Detailed Link OAM Status for Port 6: Peer: MTU Size |
| 1.3.6.1.4.1.4756.20.500.20.1.756 | ColumnnidPort6PeerMultiStateLocal | read-only | current | NID Series card Detailed Link OAM Status for Port 6: Peer: Multiplexer State |
| 1.3.6.1.4.1.4756.20.500.20.1.757 | ColumnnidPort6PeerParserStateLocal | read-only | current | NID Series card Detailed Link OAM Status for Port 6: Peer: Multiplexer State |
| 1.3.6.1.4.1.4756.20.500.20.1.758 | ColumnnidPort6PeerOUILocal | read-only | current | NID Series card Detailed Link OAM Status for Port 6: Peer: Organizational Unique Identification |
| 1.3.6.1.4.1.4756.20.500.20.1.759 | ColumnnidPort6PeerPDURevLocal | read-only | current | NID Series card Detailed Link OAM Status for Port 6: Peer: PDU Revision |
| 1.3.6.1.4.1.4756.20.500.20.1.760 | ColumnnidPort7PDUPermisionLocal | read-only | current | NID Series card Detailed Link OAM Status for Port 7: PDU Permission |
| 1.3.6.1.4.1.4756.20.500.20.1.761 | ColumnnidPort7DiscoveryStateLocal | read-only | current | NID Series card Detailed Link OAM Status for Port 7: Discovery State |
| 1.3.6.1.4.1.4756.20.500.20.1.762 | ColumnnidPort7PeerMACAddrLocal | read-only | current | NID Series card Detailed Link OAM Status for Port 7: Discovery State |
| 1.3.6.1.4.1.4756.20.500.20.1.763 | ColumnnidPort7LocalModeLocal | read-only | current | NID Series card Detailed Link OAM Status for Port 7: Local: Mode |
| 1.3.6.1.4.1.4756.20.500.20.1.764 | ColumnnidPort7LocalUnOperationLocal | read-only | current | NID Series card Detailed Link OAM Status for Port 7: Local: Unidirectional Operation Support |
| 1.3.6.1.4.1.4756.20.500.20.1.765 | ColumnnidPort7LocalRemoteLbLocal | read-only | current | NID Series card Detailed Link OAM Status for Port 7: Local: Remote Loopback Support |
| 1.3.6.1.4.1.4756.20.500.20.1.766 | ColumnnidPort7LocalLMLocal | read-only | current | NID Series card Detailed Link OAM Status for Port 7: Local: Link Monitoring Support |
| 1.3.6.1.4.1.4756.20.500.20.1.767 | ColumnnidPort7LocalMIBRetrievalLocal | read-only | current | NID Series card Detailed Link OAM Status for Port 7: Local: MIB Retrieval Support |
| 1.3.6.1.4.1.4756.20.500.20.1.768 | ColumnnidPort7LocalMTUSizeLocal | read-only | current | NID Series card Detailed Link OAM Status for Port 7: Local: MTU Size |
| 1.3.6.1.4.1.4756.20.500.20.1.769 | ColumnnidPort7LocalMultiStateLocal | read-only | current | NID Series card Detailed Link OAM Status for Port 7: Local: Multiplexer State |
| 1.3.6.1.4.1.4756.20.500.20.1.770 | ColumnnidPort7LocalParserStateLocal | read-only | current | NID Series card Detailed Link OAM Status for Port 7: Local: Multiplexer State |
| 1.3.6.1.4.1.4756.20.500.20.1.771 | ColumnnidPort7LocalOUILocal | read-only | current | NID Series card Detailed Link OAM Status for Port 7: Local: Organizational Unique Identification |
| 1.3.6.1.4.1.4756.20.500.20.1.772 | ColumnnidPort7LocalPDURevLocal | read-only | current | NID Series card Detailed Link OAM Status for Port 7: Local: PDU Revision |
| 1.3.6.1.4.1.4756.20.500.20.1.773 | ColumnnidPort7PeerModeLocal | read-only | current | NID Series card Detailed Link OAM Status for Port 7: Peer: Mode |
| 1.3.6.1.4.1.4756.20.500.20.1.774 | ColumnnidPort7PeerUnOperationLocal | read-only | current | NID Series card Detailed Link OAM Status for Port 7: Peer: Unidirectional Operation Support |
| 1.3.6.1.4.1.4756.20.500.20.1.775 | ColumnnidPort7PeerRemoteLbLocal | read-only | current | NID Series card Detailed Link OAM Status for Port 7: Peer: Remote Loopback Support |
| 1.3.6.1.4.1.4756.20.500.20.1.776 | ColumnnidPort7PeerLMLocal | read-only | current | NID Series card Detailed Link OAM Status for Port 7: Peer: Link Monitoring Support |
| 1.3.6.1.4.1.4756.20.500.20.1.777 | ColumnnidPort7PeerMIBRetrievalLocal | read-only | current | NID Series card Detailed Link OAM Status for Port 7: Peer: MIB Retrieval Support |
| 1.3.6.1.4.1.4756.20.500.20.1.778 | ColumnnidPort7PeerMTUSizeLocal | read-only | current | NID Series card Detailed Link OAM Status for Port 7: Peer: MTU Size |
| 1.3.6.1.4.1.4756.20.500.20.1.779 | ColumnnidPort7PeerMultiStateLocal | read-only | current | NID Series card Detailed Link OAM Status for Port 7: Peer: Multiplexer State |
| 1.3.6.1.4.1.4756.20.500.20.1.780 | ColumnnidPort7PeerParserStateLocal | read-only | current | NID Series card Detailed Link OAM Status for Port 7: Peer: Multiplexer State |
| 1.3.6.1.4.1.4756.20.500.20.1.781 | ColumnnidPort7PeerOUILocal | read-only | current | NID Series card Detailed Link OAM Status for Port 7: Peer: Organizational Unique Identification |
| 1.3.6.1.4.1.4756.20.500.20.1.782 | ColumnnidPort7PeerPDURevLocal | read-only | current | NID Series card Detailed Link OAM Status for Port 7: Peer: PDU Revision |
| 1.3.6.1.4.1.4756.20.500.20.1.783 | ColumnnidPort8PDUPermisionLocal | read-only | current | NID Series card Detailed Link OAM Status for Port 8: PDU Permission |
| 1.3.6.1.4.1.4756.20.500.20.1.784 | ColumnnidPort8DiscoveryStateLocal | read-only | current | NID Series card Detailed Link OAM Status for Port 8: Discovery State |
| 1.3.6.1.4.1.4756.20.500.20.1.785 | ColumnnidPort8PeerMACAddrLocal | read-only | current | NID Series card Detailed Link OAM Status for Port 8: Discovery State |
| 1.3.6.1.4.1.4756.20.500.20.1.786 | ColumnnidPort8LocalModeLocal | read-only | current | NID Series card Detailed Link OAM Status for Port 8: Local: Mode |
| 1.3.6.1.4.1.4756.20.500.20.1.787 | ColumnnidPort8LocalUnOperationLocal | read-only | current | NID Series card Detailed Link OAM Status for Port 8: Local: Unidirectional Operation Support |
| 1.3.6.1.4.1.4756.20.500.20.1.788 | ColumnnidPort8LocalRemoteLbLocal | read-only | current | NID Series card Detailed Link OAM Status for Port 8: Local: Remote Loopback Support |
| 1.3.6.1.4.1.4756.20.500.20.1.789 | ColumnnidPort8LocalLMLocal | read-only | current | NID Series card Detailed Link OAM Status for Port 8: Local: Link Monitoring Support |
| 1.3.6.1.4.1.4756.20.500.20.1.790 | ColumnnidPort8LocalMIBRetrievalLocal | read-only | current | NID Series card Detailed Link OAM Status for Port 8: Local: MIB Retrieval Support |
| 1.3.6.1.4.1.4756.20.500.20.1.791 | ColumnnidPort8LocalMTUSizeLocal | read-only | current | NID Series card Detailed Link OAM Status for Port 8: Local: MTU Size |
| 1.3.6.1.4.1.4756.20.500.20.1.792 | ColumnnidPort8LocalMultiStateLocal | read-only | current | NID Series card Detailed Link OAM Status for Port 8: Local: Multiplexer State |
| 1.3.6.1.4.1.4756.20.500.20.1.793 | ColumnnidPort8LocalParserStateLocal | read-only | current | NID Series card Detailed Link OAM Status for Port 8: Local: Multiplexer State |
| 1.3.6.1.4.1.4756.20.500.20.1.794 | ColumnnidPort8LocalOUILocal | read-only | current | NID Series card Detailed Link OAM Status for Port 8: Local: Organizational Unique Identification |
| 1.3.6.1.4.1.4756.20.500.20.1.795 | ColumnnidPort8LocalPDURevLocal | read-only | current | NID Series card Detailed Link OAM Status for Port 8: Local: PDU Revision |
| 1.3.6.1.4.1.4756.20.500.20.1.796 | ColumnnidPort8PeerModeLocal | read-only | current | NID Series card Detailed Link OAM Status for Port 8: Peer: Mode |
| 1.3.6.1.4.1.4756.20.500.20.1.797 | ColumnnidPort8PeerUnOperationLocal | read-only | current | NID Series card Detailed Link OAM Status for Port 8: Peer: Unidirectional Operation Support |
| 1.3.6.1.4.1.4756.20.500.20.1.798 | ColumnnidPort8PeerRemoteLbLocal | read-only | current | NID Series card Detailed Link OAM Status for Port 8: Peer: Remote Loopback Support |
| 1.3.6.1.4.1.4756.20.500.20.1.799 | ColumnnidPort8PeerLMLocal | read-only | current | NID Series card Detailed Link OAM Status for Port 8: Peer: Link Monitoring Support |
| 1.3.6.1.4.1.4756.20.500.20.1.800 | ColumnnidPort8PeerMIBRetrievalLocal | read-only | current | NID Series card Detailed Link OAM Status for Port 8: Peer: MIB Retrieval Support |
| 1.3.6.1.4.1.4756.20.500.20.1.801 | ColumnnidPort8PeerMTUSizeLocal | read-only | current | NID Series card Detailed Link OAM Status for Port 8: Peer: MTU Size |
| 1.3.6.1.4.1.4756.20.500.20.1.802 | ColumnnidPort8PeerMultiStateLocal | read-only | current | NID Series card Detailed Link OAM Status for Port 8: Peer: Multiplexer State |
| 1.3.6.1.4.1.4756.20.500.20.1.803 | ColumnnidPort8PeerParserStateLocal | read-only | current | NID Series card Detailed Link OAM Status for Port 8: Peer: Multiplexer State |
| 1.3.6.1.4.1.4756.20.500.20.1.804 | ColumnnidPort8PeerOUILocal | read-only | current | NID Series card Detailed Link OAM Status for Port 8: Peer: Organizational Unique Identification |
| 1.3.6.1.4.1.4756.20.500.20.1.805 | ColumnnidPort8PeerPDURevLocal | read-only | current | NID Series card Detailed Link OAM Status for Port 8: Peer: PDU Revision |
| 1.3.6.1.4.1.4756.20.500.20.1.806 | ColumnnidLoopProtectionEnableLocal | read-write | current | NID Series card Loop Protection Configuration: General Settings - Enable Loop Protection 0: Disable 1: Enable |
| 1.3.6.1.4.1.4756.20.500.20.1.807 | ColumnnidLoopProtectionTxTimeLocal | read-write | current | NID Series card Loop Protection Configuration: General Settings - Transmission Time |
| 1.3.6.1.4.1.4756.20.500.20.1.808 | ColumnnidLoopProtectionShutdownTimeLocal | read-write | current | NID Series card Loop Protection Configuration: General Settings - Shutdown Time |
| 1.3.6.1.4.1.4756.20.500.20.1.809 | ColumnnidLoopProtectionPort1EnabledLocal | read-write | current | NID Series card Loop Protection Configuration for Port 1: Port Configuration - Enable 0: Disable 1: Enable |
| 1.3.6.1.4.1.4756.20.500.20.1.810 | ColumnnidLoopProtectionPort1ActionLocal | read-write | current | NID Series card Loop Protection Configuration for Port 1: Port Configuration - Action 0: Shutdown Port 1: Shutdown Port And Log 2: Log Only |
| 1.3.6.1.4.1.4756.20.500.20.1.811 | ColumnnidLoopProtectionPort1TxModeLocal | read-write | current | NID Series card Loop Protection Configuration for Port 1: Port Configuration - Tx Mode 0: Disable 1: Enable |
| 1.3.6.1.4.1.4756.20.500.20.1.812 | ColumnnidLoopProtectionPort2EnabledLocal | read-write | current | NID Series card Loop Protection Configuration for Port 2: Port Configuration - Enable 0: Disable 1: Enable |
| 1.3.6.1.4.1.4756.20.500.20.1.813 | ColumnnidLoopProtectionPort2ActionLocal | read-write | current | NID Series card Loop Protection Configuration for Port 2: Port Configuration - Action 0: Shutdown Port 1: Shutdown Port And Log 2: Log Only |
| 1.3.6.1.4.1.4756.20.500.20.1.814 | ColumnnidLoopProtectionPort2TxModeLocal | read-write | current | NID Series card Loop Protection Configuration for Port 2: Port Configuration - Tx Mode 0: Disable 1: Enable |
| 1.3.6.1.4.1.4756.20.500.20.1.815 | ColumnnidLoopProtectionPort3EnabledLocal | read-write | current | NID Series card Loop Protection Configuration for Port 3: Port Configuration - Enable 0: Disable 1: Enable |
| 1.3.6.1.4.1.4756.20.500.20.1.816 | ColumnnidLoopProtectionPort3ActionLocal | read-write | current | NID Series card Loop Protection Configuration for Port 3: Port Configuration - Action 0: Shutdown Port 1: Shutdown Port And Log 2: Log Only |
| 1.3.6.1.4.1.4756.20.500.20.1.817 | ColumnnidLoopProtectionPort3TxModeLocal | read-write | current | NID Series card Loop Protection Configuration for Port 3: Port Configuration - Tx Mode 0: Disable 1: Enable |
| 1.3.6.1.4.1.4756.20.500.20.1.818 | ColumnnidLoopProtectionPort4EnabledLocal | read-write | current | NID Series card Loop Protection Configuration for Port 4: Port Configuration - Enable 0: Disable 1: Enable |
| 1.3.6.1.4.1.4756.20.500.20.1.819 | ColumnnidLoopProtectionPort4ActionLocal | read-write | current | NID Series card Loop Protection Configuration for Port 4: Port Configuration - Action 0: Shutdown Port 1: Shutdown Port And Log 2: Log Only |
| 1.3.6.1.4.1.4756.20.500.20.1.820 | ColumnnidLoopProtectionPort4TxModeLocal | read-write | current | NID Series card Loop Protection Configuration for Port 41: Port Configuration - Tx Mode 0: Disable 1: Enable |
| 1.3.6.1.4.1.4756.20.500.20.1.821 | ColumnnidLoopProtectionPort5EnabledLocal | read-write | current | NID Series card Loop Protection Configuration for Port 5: Port Configuration - Enable 0: Disable 1: Enable |
| 1.3.6.1.4.1.4756.20.500.20.1.822 | ColumnnidLoopProtectionPort5ActionLocal | read-write | current | NID Series card Loop Protection Configuration for Port 5: Port Configuration - Action 0: Shutdown Port 1: Shutdown Port And Log 2: Log Only |
| 1.3.6.1.4.1.4756.20.500.20.1.823 | ColumnnidLoopProtectionPort5TxModeLocal | read-write | current | NID Series card Loop Protection Configuration for Port 5: Port Configuration - Tx Mode 0: Disable 1: Enable |
| 1.3.6.1.4.1.4756.20.500.20.1.824 | ColumnnidLoopProtectionPort6EnabledLocal | read-write | current | NID Series card Loop Protection Configuration for Port 6: Port Configuration - Enable 0: Disable 1: Enable |
| 1.3.6.1.4.1.4756.20.500.20.1.825 | ColumnnidLoopProtectionPort6ActionLocal | read-write | current | NID Series card Loop Protection Configuration for Port 6: Port Configuration - Action 0: Shutdown Port 1: Shutdown Port And Log 2: Log Only |
| 1.3.6.1.4.1.4756.20.500.20.1.826 | ColumnnidLoopProtectionPort6TxModeLocal | read-write | current | NID Series card Loop Protection Configuration for Port 6: Port Configuration - Tx Mode 0: Disable 1: Enable |
| 1.3.6.1.4.1.4756.20.500.20.1.827 | ColumnnidLoopProtectionPort7EnabledLocal | read-write | current | NID Series card Loop Protection Configuration for Port 7: Port Configuration - Enable 0: Disable 1: Enable |
| 1.3.6.1.4.1.4756.20.500.20.1.828 | ColumnnidLoopProtectionPort7ActionLocal | read-write | current | NID Series card Loop Protection Configuration for Port 7: Port Configuration - Action 0: Shutdown Port 1: Shutdown Port And Log 2: Log Only |
| 1.3.6.1.4.1.4756.20.500.20.1.829 | ColumnnidLoopProtectionPort7TxModeLocal | read-write | current | NID Series card Loop Protection Configuration for Port 7: Port Configuration - Tx Mode 0: Disable 1: Enable |
| 1.3.6.1.4.1.4756.20.500.20.1.830 | ColumnnidLoopProtectionPort8EnabledLocal | read-write | current | NID Series card Loop Protection Configuration for Port 8: Port Configuration - Enable 0: Disable 1: Enable |
| 1.3.6.1.4.1.4756.20.500.20.1.831 | ColumnnidLoopProtectionPort8ActionLocal | read-write | current | NID Series card Loop Protection Configuration for Port 8: Port Configuration - Action 0: Shutdown Port 1: Shutdown Port And Log 2: Log Only |
| 1.3.6.1.4.1.4756.20.500.20.1.832 | ColumnnidLoopProtectionPort8TxModeLocal | read-write | current | NID Series card Loop Protection Configuration for Port 8: Port Configuration - Tx Mode 0: Disable 1: Enable |
| 1.3.6.1.4.1.4756.20.500.20.1.833 | ColumnnidLoopProtectionPort1ActionStsLocal | read-only | current | NID Series card Loop Protection Status for Port 1: Action |
| 1.3.6.1.4.1.4756.20.500.20.1.834 | ColumnnidLoopProtectionPort1TransStsLocal | read-only | current | NID Series card Loop Protection Status for Port 1: Transmit |
| 1.3.6.1.4.1.4756.20.500.20.1.835 | ColumnnidLoopProtectionPort1LoopsStsLocal | read-only | current | NID Series card Loop Protection Status for Port 1: Loops |
| 1.3.6.1.4.1.4756.20.500.20.1.836 | ColumnnidLoopProtectionPort1StatusLocal | read-only | current | NID Series card Loop Protection Status for Port 1: Status |
| 1.3.6.1.4.1.4756.20.500.20.1.837 | ColumnnidLoopProtectionPort1LoopStsLocal | read-only | current | NID Series card Loop Protection Status for Port 1: Loop |
| 1.3.6.1.4.1.4756.20.500.20.1.838 | ColumnnidLoopProtectionPort1TimeOfLastLoopLocal | read-only | current | NID Series card Loop Protection Status for Port 1: Time of Last Loop |
| 1.3.6.1.4.1.4756.20.500.20.1.839 | ColumnnidLoopProtectionPort2ActionStsLocal | read-only | current | NID Series card Loop Protection Status for Port 2: Action |
| 1.3.6.1.4.1.4756.20.500.20.1.840 | ColumnnidLoopProtectionPort2TransStsLocal | read-only | current | NID Series card Loop Protection Status for Port 2: Transmit |
| 1.3.6.1.4.1.4756.20.500.20.1.841 | ColumnnidLoopProtectionPort2LoopsStsLocal | read-only | current | NID Series card Loop Protection Status for Port 2: Loops |
| 1.3.6.1.4.1.4756.20.500.20.1.842 | ColumnnidLoopProtectionPort2StatusLocal | read-only | current | NID Series card Loop Protection Status for Port 2: Status |
| 1.3.6.1.4.1.4756.20.500.20.1.843 | ColumnnidLoopProtectionPort2LoopStsLocal | read-only | current | NID Series card Loop Protection Status for Port 2: Loop |
| 1.3.6.1.4.1.4756.20.500.20.1.844 | ColumnnidLoopProtectionPort2TimeOfLastLoopLocal | read-only | current | NID Series card Loop Protection Status for Port 2: Time of Last Loop |
| 1.3.6.1.4.1.4756.20.500.20.1.845 | ColumnnidLoopProtectionPort3ActionStsLocal | read-only | current | NID Series card Loop Protection Status for Port 3: Action |
| 1.3.6.1.4.1.4756.20.500.20.1.846 | ColumnnidLoopProtectionPort3TransStsLocal | read-only | current | NID Series card Loop Protection Status for Port 3: Transmit |
| 1.3.6.1.4.1.4756.20.500.20.1.847 | ColumnnidLoopProtectionPort3LoopsStsLocal | read-only | current | NID Series card Loop Protection Status for Port 3: Loops |
| 1.3.6.1.4.1.4756.20.500.20.1.848 | ColumnnidLoopProtectionPort3StatusLocal | read-only | current | NID Series card Loop Protection Status for Port 3: Status |
| 1.3.6.1.4.1.4756.20.500.20.1.849 | ColumnnidLoopProtectionPort3LoopStsLocal | read-only | current | NID Series card Loop Protection Status for Port 3: Loop |
| 1.3.6.1.4.1.4756.20.500.20.1.850 | ColumnnidLoopProtectionPort3TimeOfLastLoopLocal | read-only | current | NID Series card Loop Protection Status for Port 3: Time of Last Loop |
| 1.3.6.1.4.1.4756.20.500.20.1.851 | ColumnnidLoopProtectionPort4ActionStsLocal | read-only | current | NID Series card Loop Protection Status for Port 4: Action |
| 1.3.6.1.4.1.4756.20.500.20.1.852 | ColumnnidLoopProtectionPort4TransStsLocal | read-only | current | NID Series card Loop Protection Status for Port 4: Transmit |
| 1.3.6.1.4.1.4756.20.500.20.1.853 | ColumnnidLoopProtectionPort4LoopsStsLocal | read-only | current | NID Series card Loop Protection Status for Port 4: Loops |
| 1.3.6.1.4.1.4756.20.500.20.1.854 | ColumnnidLoopProtectionPort4StatusLocal | read-only | current | NID Series card Loop Protection Status for Port 4: Status |
| 1.3.6.1.4.1.4756.20.500.20.1.855 | ColumnnidLoopProtectionPort4LoopStsLocal | read-only | current | NID Series card Loop Protection Status for Port 4: Loop |
| 1.3.6.1.4.1.4756.20.500.20.1.856 | ColumnnidLoopProtectionPort4TimeOfLastLoopLocal | read-only | current | NID Series card Loop Protection Status for Port 4: Time of Last Loop |
| 1.3.6.1.4.1.4756.20.500.20.1.857 | ColumnnidLoopProtectionPort5ActionStsLocal | read-only | current | NID Series card Loop Protection Status for Port 5: Action |
| 1.3.6.1.4.1.4756.20.500.20.1.858 | ColumnnidLoopProtectionPort5TransStsLocal | read-only | current | NID Series card Loop Protection Status for Port 5: Transmit |
| 1.3.6.1.4.1.4756.20.500.20.1.859 | ColumnnidLoopProtectionPort5LoopsStsLocal | read-only | current | NID Series card Loop Protection Status for Port 5: Loops |
| 1.3.6.1.4.1.4756.20.500.20.1.860 | ColumnnidLoopProtectionPort5StatusLocal | read-only | current | NID Series card Loop Protection Status for Port 5: Status |
| 1.3.6.1.4.1.4756.20.500.20.1.861 | ColumnnidLoopProtectionPort5LoopStsLocal | read-only | current | NID Series card Loop Protection Status for Port 5: Loop |
| 1.3.6.1.4.1.4756.20.500.20.1.862 | ColumnnidLoopProtectionPort5TimeOfLastLoopLocal | read-only | current | NID Series card Loop Protection Status for Port 5: Time of Last Loop |
| 1.3.6.1.4.1.4756.20.500.20.1.863 | ColumnnidLoopProtectionPort6ActionStsLocal | read-only | current | NID Series card Loop Protection Status for Port 6: Action |
| 1.3.6.1.4.1.4756.20.500.20.1.864 | ColumnnidLoopProtectionPort6TransStsLocal | read-only | current | NID Series card Loop Protection Status for Port 6: Transmit |
| 1.3.6.1.4.1.4756.20.500.20.1.865 | ColumnnidLoopProtectionPort6LoopsStsLocal | read-only | current | NID Series card Loop Protection Status for Port 6: Loops |
| 1.3.6.1.4.1.4756.20.500.20.1.866 | ColumnnidLoopProtectionPort6StatusLocal | read-only | current | NID Series card Loop Protection Status for Port 64: Status |
| 1.3.6.1.4.1.4756.20.500.20.1.867 | ColumnnidLoopProtectionPort6LoopStsLocal | read-only | current | NID Series card Loop Protection Status for Port 64: Loop |
| 1.3.6.1.4.1.4756.20.500.20.1.868 | ColumnnidLoopProtectionPort6TimeOfLastLoopLocal | read-only | current | NID Series card Loop Protection Status for Port 6: Time of Last Loop |
| 1.3.6.1.4.1.4756.20.500.20.1.869 | ColumnnidLoopProtectionPort7ActionStsLocal | read-only | current | NID Series card Loop Protection Status for Port 7: Action |
| 1.3.6.1.4.1.4756.20.500.20.1.870 | ColumnnidLoopProtectionPort7TransStsLocal | read-only | current | NID Series card Loop Protection Status for Port 7: Transmit |
| 1.3.6.1.4.1.4756.20.500.20.1.871 | ColumnnidLoopProtectionPort7LoopsStsLocal | read-only | current | NID Series card Loop Protection Status for Port 7: Loops |
| 1.3.6.1.4.1.4756.20.500.20.1.872 | ColumnnidLoopProtectionPort7StatusLocal | read-only | current | NID Series card Loop Protection Status for Port 7: Status |
| 1.3.6.1.4.1.4756.20.500.20.1.873 | ColumnnidLoopProtectionPort7LoopStsLocal | read-only | current | NID Series card Loop Protection Status for Port 7: Loop |
| 1.3.6.1.4.1.4756.20.500.20.1.874 | ColumnnidLoopProtectionPort7TimeOfLastLoopLocal | read-only | current | NID Series card Loop Protection Status for Port 7: Time of Last Loop |
| 1.3.6.1.4.1.4756.20.500.20.1.875 | ColumnnidLoopProtectionPort8ActionStsLocal | read-only | current | NID Series card Loop Protection Status for Port 8: Action |
| 1.3.6.1.4.1.4756.20.500.20.1.876 | ColumnnidLoopProtectionPort8TransStsLocal | read-only | current | NID Series card Loop Protection Status for Port 8: Transmit |
| 1.3.6.1.4.1.4756.20.500.20.1.877 | ColumnnidLoopProtectionPort8LoopsStsLocal | read-only | current | NID Series card Loop Protection Status for Port 8: Loops |
| 1.3.6.1.4.1.4756.20.500.20.1.878 | ColumnnidLoopProtectionPort8StatusLocal | read-only | current | NID Series card Loop Protection Status for Port 8: Status |
| 1.3.6.1.4.1.4756.20.500.20.1.879 | ColumnnidLoopProtectionPort8LoopStsLocal | read-only | current | NID Series card Loop Protection Status for Port 8: Loop |
| 1.3.6.1.4.1.4756.20.500.20.1.880 | ColumnnidLoopProtectionPort8TimeOfLastLoopLocal | read-only | current | NID Series card Loop Protection Status for Port 8: Time of Last Loop |
| 1.3.6.1.4.1.4756.20.500.20.1.881 | ColumnniduRingInstanceAddLocal | read-write | current | NID Series card Add a new uRing Instance. Syntax: <Instance ID> <ring|sub|chain> <port east> <port west> Instance ID must be either 1 or 2 port east , the valu… |
| 1.3.6.1.4.1.4756.20.500.20.1.882 | ColumnniduRingInstanceDeleteLocal | read-write | current | NID Series card Delete a uRing Instance. Syntax: <uRing Instance> |
| 1.3.6.1.4.1.4756.20.500.20.1.883 | ColumnniduRingInst1IDLocal | read-only | current | NID Series card u-Ring instance1 ID |
| 1.3.6.1.4.1.4756.20.500.20.1.884 | ColumnniduRingInst1typeLocal | read-only | current | NID Series card u-Ring instance1 type 0: u-Ring 1: Sub-Ring 2: u-Chain |
| 1.3.6.1.4.1.4756.20.500.20.1.885 | ColumnniduRingInst1masterLocal | read-write | current | NID Series card u-Ring instance1 master 0: No 1: Yes |
| 1.3.6.1.4.1.4756.20.500.20.1.886 | ColumnniduRingInst1EastPortLocal | read-only | current | NID Series card u-Ring instance1 east port |
| 1.3.6.1.4.1.4756.20.500.20.1.887 | ColumnniduRingInst1EastEdgeLocal | read-write | current | NID Series card u-Ring instance1 east edge 0: No 1: Yes |
| 1.3.6.1.4.1.4756.20.500.20.1.888 | ColumnniduRingInst1WestPortLocal | read-only | current | NID Series card u-Ring instance1 west port |
| 1.3.6.1.4.1.4756.20.500.20.1.889 | ColumnniduRingInst1WestEdgeLocal | read-write | current | NID Series card u-Ring instance1 west edge 0: No 1: Yes |
| 1.3.6.1.4.1.4756.20.500.20.1.890 | ColumnniduRingInst2IDLocal | read-only | current | NID Series card u-Ring instance2 ID |
| 1.3.6.1.4.1.4756.20.500.20.1.891 | ColumnniduRingInst2typeLocal | read-only | current | NID Series card u-Ring instance2 type 0: u-Ring 1: Sub-Ring 2: u-Chain |
| 1.3.6.1.4.1.4756.20.500.20.1.892 | ColumnniduRingInst2masterLocal | read-write | current | NID Series card u-Ring instance2 master 0: No 1: Yes |
| 1.3.6.1.4.1.4756.20.500.20.1.893 | ColumnniduRingInst2EastPortLocal | read-only | current | NID Series card u-Ring instance2 east port |
| 1.3.6.1.4.1.4756.20.500.20.1.894 | ColumnniduRingInst2EastEdgeLocal | read-write | current | NID Series card u-Ring instance2 east edge 0: No 1: Yes |
| 1.3.6.1.4.1.4756.20.500.20.1.895 | ColumnniduRingInst2WestPortLocal | read-only | current | NID Series card u-Ring instance2 west port |
| 1.3.6.1.4.1.4756.20.500.20.1.896 | ColumnniduRingInst2WestEdgeLocal | read-write | current | NID Series card u-Ring instance2 west edge 0: No 1: Yes |
| 1.3.6.1.4.1.4756.20.500.20.1.897 | ColumnniduRingInst3IDLocal | read-only | current | NID Series card u-Ring instance3 ID |
| 1.3.6.1.4.1.4756.20.500.20.1.898 | ColumnniduRingInst3typeLocal | read-only | current | NID Series card u-Ring instance3 type 0: u-Ring 1: Sub-Ring 2: u-Chain |
| 1.3.6.1.4.1.4756.20.500.20.1.899 | ColumnniduRingInst3masterLocal | read-write | current | NID Series card u-Ring instance3 master 0: No 1: Yes |
| 1.3.6.1.4.1.4756.20.500.20.1.900 | ColumnniduRingInst3EastPortLocal | read-only | current | NID Series card u-Ring instance3 east port |
| 1.3.6.1.4.1.4756.20.500.20.1.901 | ColumnniduRingInst3EastEdgeLocal | read-write | current | NID Series card u-Ring instance3 east edge 0: No 1: Yes |
| 1.3.6.1.4.1.4756.20.500.20.1.902 | ColumnniduRingInst3WestPortLocal | read-only | current | NID Series card u-Ring instance3 west port |
| 1.3.6.1.4.1.4756.20.500.20.1.903 | ColumnniduRingInst3WestEdgeLocal | read-write | current | NID Series card u-Ring instance3 west edge 0: No 1: Yes |
| 1.3.6.1.4.1.4756.20.500.20.1.904 | ColumnniduRingInst4IDLocal | read-only | current | NID Series card u-Ring instance4 ID |
| 1.3.6.1.4.1.4756.20.500.20.1.905 | ColumnniduRingInst4typeLocal | read-only | current | NID Series card u-Ring instance4 type 0: u-Ring 1: Sub-Ring 2: u-Chain |
| 1.3.6.1.4.1.4756.20.500.20.1.906 | ColumnniduRingInst4masterLocal | read-write | current | NID Series card u-Ring instance4 master 0: No 1: Yes |
| 1.3.6.1.4.1.4756.20.500.20.1.907 | ColumnniduRingInst4EastPortLocal | read-only | current | NID Series card u-Ring instance4 east port |
| 1.3.6.1.4.1.4756.20.500.20.1.908 | ColumnniduRingInst4EastEdgeLocal | read-write | current | NID Series card u-Ring instance4 east edge 0: No 1: Yes |
| 1.3.6.1.4.1.4756.20.500.20.1.909 | ColumnniduRingInst4WestPortLocal | read-only | current | NID Series card u-Ring instance4 west port |
| 1.3.6.1.4.1.4756.20.500.20.1.910 | ColumnniduRingInst4WestEdgeLocal | read-write | current | NID Series card u-Ring instance4 west edge 0: No 1: Yes |
| 1.3.6.1.4.1.4756.20.500.20.1.911 | ColumnniduRingInst1IDstsLocal | read-only | current | NID Series card u-Ring Instance1 ID status |
| 1.3.6.1.4.1.4756.20.500.20.1.912 | ColumnniduRingInst1typestsLocal | read-only | current | NID Series card u-Ring Type status |
| 1.3.6.1.4.1.4756.20.500.20.1.913 | ColumnniduRingInst1rolestsLocal | read-only | current | NID Series card u-Ring Role status |
| 1.3.6.1.4.1.4756.20.500.20.1.914 | ColumnniduRingInst1EastPortstsLocal | read-only | current | NID Series card u-Ring East port status |
| 1.3.6.1.4.1.4756.20.500.20.1.915 | ColumnniduRingInst1EaststsLocal | read-only | current | NID Series card u-Ring East status |
| 1.3.6.1.4.1.4756.20.500.20.1.916 | ColumnniduRingInst1EastEdgestsLocal | read-only | current | NID Series card u-Ring East edge status |
| 1.3.6.1.4.1.4756.20.500.20.1.917 | ColumnniduRingInst1WestPortstsLocal | read-only | current | NID Series card u-Ring West edge status |
| 1.3.6.1.4.1.4756.20.500.20.1.918 | ColumnniduRingInst1WeststsLocal | read-only | current | NID Series card u-Ring West status |
| 1.3.6.1.4.1.4756.20.500.20.1.919 | ColumnniduRingInst1WestEdgestsLocal | read-only | current | NID Series card u-Ring West status |
| 1.3.6.1.4.1.4756.20.500.20.1.920 | ColumnniduRingInst1healthystsLocal | read-only | current | NID Series card u-Ring healthy status None Fine Fault |
| 1.3.6.1.4.1.4756.20.500.20.1.921 | ColumnniduRingInst2IDstsLocal | read-only | current | NID Series card u-Ring Instance2 ID status |
| 1.3.6.1.4.1.4756.20.500.20.1.922 | ColumnniduRingInst2typestsLocal | read-only | current | NID Series card u-Ring Type status |
| 1.3.6.1.4.1.4756.20.500.20.1.923 | ColumnniduRingInst2rolestsLocal | read-only | current | NID Series card u-Ring Role status |
| 1.3.6.1.4.1.4756.20.500.20.1.924 | ColumnniduRingInst2EastPortstsLocal | read-only | current | NID Series card u-Ring East port status |
| 1.3.6.1.4.1.4756.20.500.20.1.925 | ColumnniduRingInst2EaststsLocal | read-only | current | NID Series card u-Ring East status |
| 1.3.6.1.4.1.4756.20.500.20.1.926 | ColumnniduRingInst2EastEdgestsLocal | read-only | current | NID Series card u-Ring East edge status |
| 1.3.6.1.4.1.4756.20.500.20.1.927 | ColumnniduRingInst2WestPortstsLocal | read-only | current | NID Series card u-Ring West edge status |
| 1.3.6.1.4.1.4756.20.500.20.1.928 | ColumnniduRingInst2WeststsLocal | read-only | current | NID Series card u-Ring West status |
| 1.3.6.1.4.1.4756.20.500.20.1.929 | ColumnniduRingInst2WestEdgestsLocal | read-only | current | NID Series card u-Ring West status |
| 1.3.6.1.4.1.4756.20.500.20.1.930 | ColumnniduRingInst2healthystsLocal | read-only | current | NID Series card u-Ring healthy status None Fine Fault |
| 1.3.6.1.4.1.4756.20.500.20.1.931 | ColumnniduRingInst3IDstsLocal | read-only | current | NID Series card u-Ring Instance3 ID status |
| 1.3.6.1.4.1.4756.20.500.20.1.932 | ColumnniduRingInst3typestsLocal | read-only | current | NID Series card u-Ring Type status |
| 1.3.6.1.4.1.4756.20.500.20.1.933 | ColumnniduRingInst3rolestsLocal | read-only | current | NID Series card u-Ring Role status |
| 1.3.6.1.4.1.4756.20.500.20.1.934 | ColumnniduRingInst3EastPortstsLocal | read-only | current | NID Series card u-Ring East port status |
| 1.3.6.1.4.1.4756.20.500.20.1.935 | ColumnniduRingInst3EaststsLocal | read-only | current | NID Series card u-Ring East status |
| 1.3.6.1.4.1.4756.20.500.20.1.936 | ColumnniduRingInst3EastEdgestsLocal | read-only | current | NID Series card u-Ring East edge status |
| 1.3.6.1.4.1.4756.20.500.20.1.937 | ColumnniduRingInst3WestPortstsLocal | read-only | current | NID Series card u-Ring West edge status |
| 1.3.6.1.4.1.4756.20.500.20.1.938 | ColumnniduRingInst3WeststsLocal | read-only | current | NID Series card u-Ring West status |
| 1.3.6.1.4.1.4756.20.500.20.1.939 | ColumnniduRingInst3WestEdgestsLocal | read-only | current | NID Series card u-Ring West status |
| 1.3.6.1.4.1.4756.20.500.20.1.940 | ColumnniduRingInst3healthystsLocal | read-only | current | NID Series card u-Ring healthy status None Fine Fault |
| 1.3.6.1.4.1.4756.20.500.20.1.941 | ColumnniduRingInst4IDstsLocal | read-only | current | NID Series card u-Ring Instance4 ID status |
| 1.3.6.1.4.1.4756.20.500.20.1.942 | ColumnniduRingInst4typestsLocal | read-only | current | NID Series card u-Ring Type status |
| 1.3.6.1.4.1.4756.20.500.20.1.943 | ColumnniduRingInst4rolestsLocal | read-only | current | NID Series card u-Ring Role status |
| 1.3.6.1.4.1.4756.20.500.20.1.944 | ColumnniduRingInst4EastPortstsLocal | read-only | current | NID Series card u-Ring East port status |
| 1.3.6.1.4.1.4756.20.500.20.1.945 | ColumnniduRingInst4EaststsLocal | read-only | current | NID Series card u-Ring East status |
| 1.3.6.1.4.1.4756.20.500.20.1.946 | ColumnniduRingInst4EastEdgestsLocal | read-only | current | NID Series card u-Ring East edge status |
| 1.3.6.1.4.1.4756.20.500.20.1.947 | ColumnniduRingInst4WestPortstsLocal | read-only | current | NID Series card u-Ring West edge status |
| 1.3.6.1.4.1.4756.20.500.20.1.948 | ColumnniduRingInst4WeststsLocal | read-only | current | NID Series card u-Ring West status |
| 1.3.6.1.4.1.4756.20.500.20.1.949 | ColumnniduRingInst4WestEdgestsLocal | read-only | current | NID Series card u-Ring West status |
| 1.3.6.1.4.1.4756.20.500.20.1.950 | ColumnniduRingInst4healthystsLocal | read-only | current | NID Series card u-Ring healthy status None Fine Fault |
| 1.3.6.1.4.1.4756.20.500.20.1.951 | ColumnnidSTPProtocolVersionLocal | read-write | current | NID Series card STP Bridge Configuration: Basic Settings - Protocol Version 0: STP 1: RSTP 2: MSTP |
| 1.3.6.1.4.1.4756.20.500.20.1.952 | ColumnnidSTPBridgePriorityLocal | read-write | current | NID Series card STP Bridge Configuration: Basic Settings - Bridge Priority 0: 0 1: 4096 2: 8192 3: 12288 4: 16384 5: 20480 6: 24576 7: 28672 8: 32768 9: 36864 … |
| 1.3.6.1.4.1.4756.20.500.20.1.953 | ColumnnidSTPForwardDelayLocal | read-write | current | NID Series card STP Bridge Configuration: Basic Settings - Forward Delay |
| 1.3.6.1.4.1.4756.20.500.20.1.954 | ColumnnidSTPMaxAgeLocal | read-write | current | NID Series card STP Bridge Configuration: Basic Settings - Max Age |
| 1.3.6.1.4.1.4756.20.500.20.1.955 | ColumnnidSTPMaximumHopCountLocal | read-write | current | NID Series card STP Bridge Configuration: Basic Settings - Maximum Hop Count |
| 1.3.6.1.4.1.4756.20.500.20.1.956 | ColumnnidSTPTransmitHoldCountLocal | read-write | current | NID Series card STP Bridge Configuration: Basic Settings - Transmit Hold Count |
| 1.3.6.1.4.1.4756.20.500.20.1.957 | ColumnnidSTPEdgePortBPDUFilteringLocal | read-write | current | NID Series card STP Bridge Configuration: Advanced Settings - Edge Port BPDU Filtering 0: Off 1: On |
| 1.3.6.1.4.1.4756.20.500.20.1.958 | ColumnnidSTPEdgePortBPDUGuardLocal | read-write | current | NID Series card STP Bridge Configuration: Advanced Settings - Edge Port BPDU Guard 0: Off 1: On |
| 1.3.6.1.4.1.4756.20.500.20.1.959 | ColumnnidSTPPortErrorRecoveryTimeoutLocal | read-write | current | NID Series card STP Bridge Configuration: Advanced Settings - Port Error Recovery Timeout 0: Off 1: On |
| 1.3.6.1.4.1.4756.20.500.20.1.960 | ColumnnidMSTIConfigurationNameLocal | read-write | current | NID Series card MSTI Configuration: Configuration Identification - Configuration Name |
| 1.3.6.1.4.1.4756.20.500.20.1.961 | ColumnnidMSTIConfigurationRevisionLocal | read-write | current | NID Series card MSTI Configuration: Configuration Identification - Configuration Revision |
| 1.3.6.1.4.1.4756.20.500.20.1.962 | ColumnnidMSTI1VLANsMappingLocal | read-write | current | NID Series card MSTI Configuration: MSTI Mapping - MSTI 1 |
| 1.3.6.1.4.1.4756.20.500.20.1.963 | ColumnnidMSTI2VLANsMappingLocal | read-write | current | NID Series card MSTI Configuration: MSTI Mapping - MSTI 2 |
| 1.3.6.1.4.1.4756.20.500.20.1.964 | ColumnnidMSTI3VLANsMappingLocal | read-write | current | NID Series card MSTI Configuration: MSTI Mapping - MSTI 3 |
| 1.3.6.1.4.1.4756.20.500.20.1.965 | ColumnnidMSTI4VLANsMappingLocal | read-write | current | NID Series card MSTI Configuration: MSTI Mapping - MSTI 4 |
| 1.3.6.1.4.1.4756.20.500.20.1.966 | ColumnnidMSTI5VLANsMappingLocal | read-write | current | NID Series card MSTI Configuration: MSTI Mapping - MSTI 5 |
| 1.3.6.1.4.1.4756.20.500.20.1.967 | ColumnnidMSTI6VLANsMappingLocal | read-write | current | NID Series card MSTI Configuration: MSTI Mapping - MSTI 6 |
| 1.3.6.1.4.1.4756.20.500.20.1.968 | ColumnnidMSTI7VLANsMappingLocal | read-write | current | NID Series card MSTI Configuration: MSTI Mapping - MSTI 7 |
| 1.3.6.1.4.1.4756.20.500.20.1.969 | ColumnnidMSTI8VLANsMappingLocal | read-write | current | NID Series card MSTI Configuration: MSTI Mapping - MSTI 8 |
| 1.3.6.1.4.1.4756.20.500.20.1.970 | ColumnnidMSTI9VLANsMappingLocal | read-write | current | NID Series card MSTI Configuration: MSTI Mapping - MSTI 9 |
| 1.3.6.1.4.1.4756.20.500.20.1.971 | ColumnnidMSTI10VLANsMappingLocal | read-write | current | NID Series card MSTI Configuration: MSTI Mapping - MSTI 10 |
| 1.3.6.1.4.1.4756.20.500.20.1.972 | ColumnnidMSTI11VLANsMappingLocal | read-write | current | NID Series card MSTI Configuration: MSTI Mapping - MSTI 11 |
| 1.3.6.1.4.1.4756.20.500.20.1.973 | ColumnnidMSTI12VLANsMappingLocal | read-write | current | NID Series card MSTI Configuration: MSTI Mapping - MSTI 12 |
| 1.3.6.1.4.1.4756.20.500.20.1.974 | ColumnnidMSTI13VLANsMappingLocal | read-write | current | NID Series card MSTI Configuration: MSTI Mapping - MSTI 13 |
| 1.3.6.1.4.1.4756.20.500.20.1.975 | ColumnnidMSTI14VLANsMappingLocal | read-write | current | NID Series card MSTI Configuration: MSTI Mapping - MSTI 14 |
| 1.3.6.1.4.1.4756.20.500.20.1.976 | ColumnnidMSTI15VLANsMappingLocal | read-write | current | NID Series card MSTI Configuration: MSTI Mapping - MSTI 15 |
| 1.3.6.1.4.1.4756.20.500.20.1.977 | ColumnnidCISTAggregatedSTPEnabledLocal | read-write | current | NID Series card STP CIST Port Configuration: CIST Aggregated Port Configuration - STP Enabled |
| 1.3.6.1.4.1.4756.20.500.20.1.978 | ColumnnidCISTAggregatedPathCostLocal | read-write | current | NID Series card STP CIST Port Configuration: CIST Aggregated Port Configuration - Path Cost Valid values are in the range 0 to 200000000. Setting 0 means Auto … |
| 1.3.6.1.4.1.4756.20.500.20.1.979 | ColumnnidCISTAggregatedPriorityLocal | read-write | current | NID Series card STP CIST Port Configuration: CIST Aggregated Port Configuration - Priority |
| 1.3.6.1.4.1.4756.20.500.20.1.980 | ColumnnidCISTAggregatedAdminEdgeLocal | read-write | current | NID Series card STP CIST Port Configuration: CIST Aggregated Port Configuration - STP Enabled 0: Non-edge 1: Edge |
| 1.3.6.1.4.1.4756.20.500.20.1.981 | ColumnnidCISTAggregatedAutoEdgeLocal | read-write | current | NID Series card STP CIST Port Configuration: CIST Aggregated Port Configuration - Auto Edge 0: Non-edge 1: Edge |
| 1.3.6.1.4.1.4756.20.500.20.1.982 | ColumnnidCISTAggregatedRestrictedRoleLocal | read-write | current | NID Series card STP CIST Port Configuration: CIST Aggregated Port Configuration - Restricted Role 0: Non-edge 1: Edge |
| 1.3.6.1.4.1.4756.20.500.20.1.983 | ColumnnidCISTAggregatedRestrictedTCNLocal | read-write | current | NID Series card STP CIST Port Configuration: CIST Aggregated Port Configuration - Restricted TCN 0: Non-edge 1: Edge |
| 1.3.6.1.4.1.4756.20.500.20.1.984 | ColumnnidCISTAggregatedBPDUGuardLocal | read-write | current | NID Series card STP CIST Port Configuration: CIST Aggregated Port Configuration - BPDU Guard 0: Non-edge 1: Edge |
| 1.3.6.1.4.1.4756.20.500.20.1.985 | ColumnnidCISTAggregatedPointToPointLocal | read-write | current | NID Series card STP CIST Port Configuration: CIST Aggregated Port Configuration - Point-to-point 0: Forced True 1: Forced False 2: Auto |
| 1.3.6.1.4.1.4756.20.500.20.1.986 | ColumnnidCISTPort1STPEnabledLocal | read-write | current | NID Series card STP CIST Port Configuration: CIST Normal Port1 Configuration - STP Enabled |
| 1.3.6.1.4.1.4756.20.500.20.1.987 | ColumnnidCISTPort1PathCostLocal | read-write | current | NID Series card STP CIST Port Configuration: CIST Normal Port1 Configuration - Path Cost Valid values are in the range 0 to 200000000. Setting 0 means Auto pat… |
| 1.3.6.1.4.1.4756.20.500.20.1.988 | ColumnnidCISTPort1PriorityLocal | read-write | current | NID Series card STP CIST Port Configuration: CIST Normal Port1 Configuration - Priority |
| 1.3.6.1.4.1.4756.20.500.20.1.989 | ColumnnidCISTPort1AdminEdgeLocal | read-write | current | NID Series card STP CIST Port Configuration: CIST Normal Port1 Configuration - STP Enabled 0: Non-edge 1: Edge |
| 1.3.6.1.4.1.4756.20.500.20.1.990 | ColumnnidCISTPort1AutoEdgeLocal | read-write | current | NID Series card STP CIST Port Configuration: CIST Normal Port1 Configuration - Auto Edge 0: Non-edge 1: Edge |
| 1.3.6.1.4.1.4756.20.500.20.1.991 | ColumnnidCISTPort1RestrictedRoleLocal | read-write | current | NID Series card STP CIST Port Configuration: CIST Normal Port1 Configuration - Restricted Role 0: Non-edge 1: Edge |
| 1.3.6.1.4.1.4756.20.500.20.1.992 | ColumnnidCISTPort1RestrictedTCNLocal | read-write | current | NID Series card STP CIST Port Configuration: CIST Normal Port1 Configuration - Restricted TCN 0: Non-edge 1: Edge |
| 1.3.6.1.4.1.4756.20.500.20.1.993 | ColumnnidCISTPort1BPDUGuardLocal | read-write | current | NID Series card STP CIST Port Configuration: CIST Normal Port1 Configuration - BPDU Guard 0: Non-edge 1: Edge |
| 1.3.6.1.4.1.4756.20.500.20.1.994 | ColumnnidCISTPort1PointToPointLocal | read-write | current | NID Series card STP CIST Port Configuration: CIST Normal Port1 Configuration - Point-to-point 0: Forced True 1: Forced False 2: Auto |
| 1.3.6.1.4.1.4756.20.500.20.1.995 | ColumnnidCISTPort2STPEnabledLocal | read-write | current | NID Series card STP CIST Port Configuration: CIST Normal Port2 Configuration - STP Enabled |
| 1.3.6.1.4.1.4756.20.500.20.1.996 | ColumnnidCISTPort2PathCostLocal | read-write | current | NID Series card STP CIST Port Configuration: CIST Normal Port2 Configuration - Path Cost Valid values are in the range 0 to 200000000. Setting 0 means Auto pat… |
| 1.3.6.1.4.1.4756.20.500.20.1.997 | ColumnnidCISTPort2PriorityLocal | read-write | current | NID Series card STP CIST Port Configuration: CIST Normal Port2 Configuration - Priority |
| 1.3.6.1.4.1.4756.20.500.20.1.998 | ColumnnidCISTPort2AdminEdgeLocal | read-write | current | NID Series card STP CIST Port Configuration: CIST Normal Port2 Configuration - STP Enabled 0: Non-edge 1: Edge |
| 1.3.6.1.4.1.4756.20.500.20.1.999 | ColumnnidCISTPort2AutoEdgeLocal | read-write | current | NID Series card STP CIST Port Configuration: CIST Normal Port2 Configuration - Auto Edge 0: Non-edge 1: Edge |
| 1.3.6.1.4.1.4756.20.500.20.1.1000 | ColumnnidCISTPort2RestrictedRoleLocal | read-write | current | NID Series card STP CIST Port Configuration: CIST Normal Port2 Configuration - Restricted Role 0: Non-edge 1: Edge |
| 1.3.6.1.4.1.4756.20.500.20.1.1001 | ColumnnidCISTPort2RestrictedTCNLocal | read-write | current | NID Series card STP CIST Port Configuration: CIST Normal Port2 Configuration - Restricted TCN 0: Non-edge 1: Edge |
| 1.3.6.1.4.1.4756.20.500.20.1.1002 | ColumnnidCISTPort2BPDUGuardLocal | read-write | current | NID Series card STP CIST Port Configuration: CIST Normal Port2 Configuration - BPDU Guard 0: Non-edge 1: Edge |
| 1.3.6.1.4.1.4756.20.500.20.1.1003 | ColumnnidCISTPort2PointToPointLocal | read-write | current | NID Series card STP CIST Port Configuration: CIST Normal Port2 Configuration - Point-to-point 0: Forced True 1: Forced False 2: Auto |
| 1.3.6.1.4.1.4756.20.500.20.1.1004 | ColumnnidCISTPort3STPEnabledLocal | read-write | current | NID Series card STP CIST Port Configuration: CIST Normal Port3 Configuration - STP Enabled |
| 1.3.6.1.4.1.4756.20.500.20.1.1005 | ColumnnidCISTPort3PathCostLocal | read-write | current | NID Series card STP CIST Port Configuration: CIST Normal Port3 Configuration - Path Cost Valid values are in the range 0 to 200000000. Setting 0 means Auto pat… |
| 1.3.6.1.4.1.4756.20.500.20.1.1006 | ColumnnidCISTPort3PriorityLocal | read-write | current | NID Series card STP CIST Port Configuration: CIST Normal Port3 Configuration - Priority |
| 1.3.6.1.4.1.4756.20.500.20.1.1007 | ColumnnidCISTPort3AdminEdgeLocal | read-write | current | NID Series card STP CIST Port Configuration: CIST Normal Port3 Configuration - STP Enabled 0: Non-edge 1: Edge |
| 1.3.6.1.4.1.4756.20.500.20.1.1008 | ColumnnidCISTPort3AutoEdgeLocal | read-write | current | NID Series card STP CIST Port Configuration: CIST Normal Port3 Configuration - Auto Edge 0: Non-edge 1: Edge |
| 1.3.6.1.4.1.4756.20.500.20.1.1009 | ColumnnidCISTPort3RestrictedRoleLocal | read-write | current | NID Series card STP CIST Port Configuration: CIST Normal Port3 Configuration - Restricted Role 0: Non-edge 1: Edge |
| 1.3.6.1.4.1.4756.20.500.20.1.1010 | ColumnnidCISTPort3RestrictedTCNLocal | read-write | current | NID Series card STP CIST Port Configuration: CIST Normal Port3 Configuration - Restricted TCN 0: Non-edge 1: Edge |
| 1.3.6.1.4.1.4756.20.500.20.1.1011 | ColumnnidCISTPort3BPDUGuardLocal | read-write | current | NID Series card STP CIST Port Configuration: CIST Normal Port3 Configuration - BPDU Guard 0: Non-edge 1: Edge |
| 1.3.6.1.4.1.4756.20.500.20.1.1012 | ColumnnidCISTPort3PointToPointLocal | read-write | current | NID Series card STP CIST Port Configuration: CIST Normal Port3 Configuration - Point-to-point 0: Forced True 1: Forced False 2: Auto |
| 1.3.6.1.4.1.4756.20.500.20.1.1013 | ColumnnidCISTPort4STPEnabledLocal | read-write | current | NID Series card STP CIST Port Configuration: CIST Normal Port4 Configuration - STP Enabled |
| 1.3.6.1.4.1.4756.20.500.20.1.1014 | ColumnnidCISTPort4PathCostLocal | read-write | current | NID Series card STP CIST Port Configuration: CIST Normal Port4 Configuration - Path Cost Valid values are in the range 0 to 200000000. Setting 0 means Auto pat… |
| 1.3.6.1.4.1.4756.20.500.20.1.1015 | ColumnnidCISTPort4PriorityLocal | read-write | current | NID Series card STP CIST Port Configuration: CIST Normal Port4 Configuration - Priority |
| 1.3.6.1.4.1.4756.20.500.20.1.1016 | ColumnnidCISTPort4AdminEdgeLocal | read-write | current | NID Series card STP CIST Port Configuration: CIST Normal Port4 Configuration - STP Enabled 0: Non-edge 1: Edge |
| 1.3.6.1.4.1.4756.20.500.20.1.1017 | ColumnnidCISTPort4AutoEdgeLocal | read-write | current | NID Series card STP CIST Port Configuration: CIST Normal Port4 Configuration - Auto Edge 0: Non-edge 1: Edge |
| 1.3.6.1.4.1.4756.20.500.20.1.1018 | ColumnnidCISTPort4RestrictedRoleLocal | read-write | current | NID Series card STP CIST Port Configuration: CIST Normal Port4 Configuration - Restricted Role 0: Non-edge 1: Edge |
| 1.3.6.1.4.1.4756.20.500.20.1.1019 | ColumnnidCISTPort4RestrictedTCNLocal | read-write | current | NID Series card STP CIST Port Configuration: CIST Normal Port4 Configuration - Restricted TCN 0: Non-edge 1: Edge |
| 1.3.6.1.4.1.4756.20.500.20.1.1020 | ColumnnidCISTPort4BPDUGuardLocal | read-write | current | NID Series card STP CIST Port Configuration: CIST Normal Port4 Configuration - BPDU Guard 0: Non-edge 1: Edge |
| 1.3.6.1.4.1.4756.20.500.20.1.1021 | ColumnnidCISTPort4PointToPointLocal | read-write | current | NID Series card STP CIST Port Configuration: CIST Normal Port4 Configuration - Point-to-point 0: Forced True 1: Forced False 2: Auto |
| 1.3.6.1.4.1.4756.20.500.20.1.1022 | ColumnnidCISTPort5STPEnabledLocal | read-write | current | NID Series card STP CIST Port Configuration: CIST Normal Port5 Configuration - STP Enabled |
| 1.3.6.1.4.1.4756.20.500.20.1.1023 | ColumnnidCISTPort5PathCostLocal | read-write | current | NID Series card STP CIST Port Configuration: CIST Normal Port5 Configuration - Path Cost Valid values are in the range 0 to 200000000. Setting 0 means Auto pat… |
| 1.3.6.1.4.1.4756.20.500.20.1.1024 | ColumnnidCISTPort5PriorityLocal | read-write | current | NID Series card STP CIST Port Configuration: CIST Normal Port5 Configuration - Priority |
| 1.3.6.1.4.1.4756.20.500.20.1.1025 | ColumnnidCISTPort5AdminEdgeLocal | read-write | current | NID Series card STP CIST Port Configuration: CIST Normal Port5 Configuration - STP Enabled 0: Non-edge 1: Edge |
| 1.3.6.1.4.1.4756.20.500.20.1.1026 | ColumnnidCISTPort5AutoEdgeLocal | read-write | current | NID Series card STP CIST Port Configuration: CIST Normal Port5 Configuration - Auto Edge 0: Non-edge 1: Edge |
| 1.3.6.1.4.1.4756.20.500.20.1.1027 | ColumnnidCISTPort5RestrictedRoleLocal | read-write | current | NID Series card STP CIST Port Configuration: CIST Normal Port5 Configuration - Restricted Role 0: Non-edge 1: Edge |
| 1.3.6.1.4.1.4756.20.500.20.1.1028 | ColumnnidCISTPort5RestrictedTCNLocal | read-write | current | NID Series card STP CIST Port Configuration: CIST Normal Port5 Configuration - Restricted TCN 0: Non-edge 1: Edge |
| 1.3.6.1.4.1.4756.20.500.20.1.1029 | ColumnnidCISTPort5BPDUGuardLocal | read-write | current | NID Series card STP CIST Port Configuration: CIST Normal Port5 Configuration - BPDU Guard 0: Non-edge 1: Edge |
| 1.3.6.1.4.1.4756.20.500.20.1.1030 | ColumnnidCISTPort5PointToPointLocal | read-write | current | NID Series card STP CIST Port Configuration: CIST Normal Port5 Configuration - Point-to-point 0: Forced True 1: Forced False 2: Auto |
| 1.3.6.1.4.1.4756.20.500.20.1.1031 | ColumnnidCISTPort6STPEnabledLocal | read-write | current | NID Series card STP CIST Port Configuration: CIST Normal Port6 Configuration - STP Enabled |
| 1.3.6.1.4.1.4756.20.500.20.1.1032 | ColumnnidCISTPort6PathCostLocal | read-write | current | NID Series card STP CIST Port Configuration: CIST Normal Port6 Configuration - Path Cost Valid values are in the range 0 to 200000000. Setting 0 means Auto pat… |
| 1.3.6.1.4.1.4756.20.500.20.1.1033 | ColumnnidCISTPort6PriorityLocal | read-write | current | NID Series card STP CIST Port Configuration: CIST Normal Port6 Configuration - Priority |
| 1.3.6.1.4.1.4756.20.500.20.1.1034 | ColumnnidCISTPort6AdminEdgeLocal | read-write | current | NID Series card STP CIST Port Configuration: CIST Normal Port6 Configuration - STP Enabled 0: Non-edge 1: Edge |
| 1.3.6.1.4.1.4756.20.500.20.1.1035 | ColumnnidCISTPort6AutoEdgeLocal | read-write | current | NID Series card STP CIST Port Configuration: CIST Normal Port6 Configuration - Auto Edge 0: Non-edge 1: Edge |
| 1.3.6.1.4.1.4756.20.500.20.1.1036 | ColumnnidCISTPort6RestrictedRoleLocal | read-write | current | NID Series card STP CIST Port Configuration: CIST Normal Port6 Configuration - Restricted Role 0: Non-edge 1: Edge |
| 1.3.6.1.4.1.4756.20.500.20.1.1037 | ColumnnidCISTPort6RestrictedTCNLocal | read-write | current | NID Series card STP CIST Port Configuration: CIST Normal Port6 Configuration - Restricted TCN 0: Non-edge 1: Edge |
| 1.3.6.1.4.1.4756.20.500.20.1.1038 | ColumnnidCISTPort6BPDUGuardLocal | read-write | current | NID Series card STP CIST Port Configuration: CIST Normal Port6 Configuration - BPDU Guard 0: Non-edge 1: Edge |
| 1.3.6.1.4.1.4756.20.500.20.1.1039 | ColumnnidCISTPort6PointToPointLocal | read-write | current | NID Series card STP CIST Port Configuration: CIST Normal Port6 Configuration - Point-to-point 0: Forced True 1: Forced False 2: Auto |
| 1.3.6.1.4.1.4756.20.500.20.1.1040 | ColumnnidCISTPort7STPEnabledLocal | read-write | current | NID Series card STP CIST Port Configuration: CIST Normal Port7 Configuration - STP Enabled |
| 1.3.6.1.4.1.4756.20.500.20.1.1041 | ColumnnidCISTPort7PathCostLocal | read-write | current | NID Series card STP CIST Port Configuration: CIST Normal Port7 Configuration - Path Cost Valid values are in the range 0 to 200000000. Setting 0 means Auto pat… |
| 1.3.6.1.4.1.4756.20.500.20.1.1042 | ColumnnidCISTPort7PriorityLocal | read-write | current | NID Series card STP CIST Port Configuration: CIST Normal Port7 Configuration - Priority |
| 1.3.6.1.4.1.4756.20.500.20.1.1043 | ColumnnidCISTPort7AdminEdgeLocal | read-write | current | NID Series card STP CIST Port Configuration: CIST Normal Port7 Configuration - STP Enabled 0: Non-edge 1: Edge |
| 1.3.6.1.4.1.4756.20.500.20.1.1044 | ColumnnidCISTPort7AutoEdgeLocal | read-write | current | NID Series card STP CIST Port Configuration: CIST Normal Port7 Configuration - Auto Edge 0: Non-edge 1: Edge |
| 1.3.6.1.4.1.4756.20.500.20.1.1045 | ColumnnidCISTPort7RestrictedRoleLocal | read-write | current | NID Series card STP CIST Port Configuration: CIST Normal Port7 Configuration - Restricted Role 0: Non-edge 1: Edge |
| 1.3.6.1.4.1.4756.20.500.20.1.1046 | ColumnnidCISTPort7RestrictedTCNLocal | read-write | current | NID Series card STP CIST Port Configuration: CIST Normal Port7 Configuration - Restricted TCN 0: Non-edge 1: Edge |
| 1.3.6.1.4.1.4756.20.500.20.1.1047 | ColumnnidCISTPort7BPDUGuardLocal | read-write | current | NID Series card STP CIST Port Configuration: CIST Normal Port7 Configuration - BPDU Guard 0: Non-edge 1: Edge |
| 1.3.6.1.4.1.4756.20.500.20.1.1048 | ColumnnidCISTPort7PointToPointLocal | read-write | current | NID Series card STP CIST Port Configuration: CIST Normal Port7 Configuration - Point-to-point 0: Forced True 1: Forced False 2: Auto |
| 1.3.6.1.4.1.4756.20.500.20.1.1049 | ColumnnidCISTPort8STPEnabledLocal | read-write | current | NID Series card STP CIST Port Configuration: CIST Normal Port8 Configuration - STP Enabled |
| 1.3.6.1.4.1.4756.20.500.20.1.1050 | ColumnnidCISTPort8PathCostLocal | read-write | current | NID Series card STP CIST Port Configuration: CIST Normal Port8 Configuration - Path Cost Valid values are in the range 0 to 200000000. Setting 0 means Auto pat… |
| 1.3.6.1.4.1.4756.20.500.20.1.1051 | ColumnnidCISTPort8PriorityLocal | read-write | current | NID Series card STP CIST Port Configuration: CIST Normal Port8 Configuration - Priority |
| 1.3.6.1.4.1.4756.20.500.20.1.1052 | ColumnnidCISTPort8AdminEdgeLocal | read-write | current | NID Series card STP CIST Port Configuration: CIST Normal Port8 Configuration - STP Enabled 0: Non-edge 1: Edge |
| 1.3.6.1.4.1.4756.20.500.20.1.1053 | ColumnnidCISTPort8AutoEdgeLocal | read-write | current | NID Series card STP CIST Port Configuration: CIST Normal Port8 Configuration - Auto Edge 0: Non-edge 1: Edge |
| 1.3.6.1.4.1.4756.20.500.20.1.1054 | ColumnnidCISTPort8RestrictedRoleLocal | read-write | current | NID Series card STP CIST Port Configuration: CIST Normal Port8 Configuration - Restricted Role 0: Non-edge 1: Edge |
| 1.3.6.1.4.1.4756.20.500.20.1.1055 | ColumnnidCISTPort8RestrictedTCNLocal | read-write | current | NID Series card STP CIST Port Configuration: CIST Normal Port8 Configuration - Restricted TCN 0: Non-edge 1: Edge |
| 1.3.6.1.4.1.4756.20.500.20.1.1056 | ColumnnidCISTPort8BPDUGuardLocal | read-write | current | NID Series card STP CIST Port Configuration: CIST Normal Port8 Configuration - BPDU Guard 0: Non-edge 1: Edge |
| 1.3.6.1.4.1.4756.20.500.20.1.1057 | ColumnnidCISTPort8PointToPointLocal | read-write | current | NID Series card STP CIST Port Configuration: CIST Normal Port8 Configuration - Point-to-point 0: Forced True 1: Forced False 2: Auto |
| 1.3.6.1.4.1.4756.20.500.20.1.1058 | ColumnnidMSTI1AggregatedPathCostLocal | read-write | current | NID Series card MSTI Port Configuration: MSTI1 Aggregated Ports Configuration - Path Cost Valid values are in the range 0 to 200000000. Setting 0 means Auto pa… |
| 1.3.6.1.4.1.4756.20.500.20.1.1059 | ColumnnidMSTI1AggregatedPriorityLocal | read-write | current | NID Series card MSTI Port Configuration: MSTI1 Aggregated Ports Configuration - Priority |
| 1.3.6.1.4.1.4756.20.500.20.1.1060 | ColumnnidMSTI1Port1PathCostLocal | read-write | current | NID Series card MSTI Port Configuration: MSTI1 Normal Port1 Configuration - Path Cost Valid values are in the range 0 to 200000000. Setting 0 means Auto path c… |
| 1.3.6.1.4.1.4756.20.500.20.1.1061 | ColumnnidMSTI1Port1PriorityLocal | read-write | current | NID Series card MSTI Port Configuration: MSTI1 Normal Port1 Configuration - Priority |
| 1.3.6.1.4.1.4756.20.500.20.1.1062 | ColumnnidMSTI1Port2PathCostLocal | read-write | current | NID Series card MSTI Port Configuration: MSTI1 Normal Port2 Configuration - Path Cost Valid values are in the range 0 to 200000000. Setting 0 means Auto path c… |
| 1.3.6.1.4.1.4756.20.500.20.1.1063 | ColumnnidMSTI1Port2PriorityLocal | read-write | current | NID Series card MSTI Port Configuration: MSTI1 Normal Port2 Configuration - Priority |
| 1.3.6.1.4.1.4756.20.500.20.1.1064 | ColumnnidMSTI1Port3PathCostLocal | read-write | current | NID Series card MSTI Port Configuration: MSTI1 Normal Port3 Configuration - Path Cost Valid values are in the range 0 to 200000000. Setting 0 means Auto path c… |
| 1.3.6.1.4.1.4756.20.500.20.1.1065 | ColumnnidMSTI1Port3PriorityLocal | read-write | current | NID Series card MSTI Port Configuration: MSTI1 Normal Port3 Configuration - Priority |
| 1.3.6.1.4.1.4756.20.500.20.1.1066 | ColumnnidMSTI1Port4PathCostLocal | read-write | current | NID Series card MSTI Port Configuration: MSTI1 Normal Port4 Configuration - Path Cost Valid values are in the range 0 to 200000000. Setting 0 means Auto path c… |
| 1.3.6.1.4.1.4756.20.500.20.1.1067 | ColumnnidMSTI1Port4PriorityLocal | read-write | current | NID Series card MSTI Port Configuration: MSTI1 Normal Port4 Configuration - Priority |
| 1.3.6.1.4.1.4756.20.500.20.1.1068 | ColumnnidMSTI1Port5PathCostLocal | read-write | current | NID Series card MSTI Port Configuration: MSTI1 Normal Port5 Configuration - Path Cost Valid values are in the range 0 to 200000000. Setting 0 means Auto path c… |
| 1.3.6.1.4.1.4756.20.500.20.1.1069 | ColumnnidMSTI1Port5PriorityLocal | read-write | current | NID Series card MSTI Port Configuration: MSTI1 Normal Port5 Configuration - Priority |
| 1.3.6.1.4.1.4756.20.500.20.1.1070 | ColumnnidMSTI1Port6PathCostLocal | read-write | current | NID Series card MSTI Port Configuration: MSTI1 Normal Port6 Configuration - Path Cost Valid values are in the range 0 to 200000000. Setting 0 means Auto path c… |
| 1.3.6.1.4.1.4756.20.500.20.1.1071 | ColumnnidMSTI1Port6PriorityLocal | read-write | current | NID Series card MSTI Port Configuration: MSTI1 Normal Port6 Configuration - Priority |
| 1.3.6.1.4.1.4756.20.500.20.1.1072 | ColumnnidMSTI1Port7PathCostLocal | read-write | current | NID Series card MSTI Port Configuration: MSTI1 Normal Port7 Configuration - Path Cost Valid values are in the range 0 to 200000000. Setting 0 means Auto path c… |
| 1.3.6.1.4.1.4756.20.500.20.1.1073 | ColumnnidMSTI1Port7PriorityLocal | read-write | current | NID Series card MSTI Port Configuration: MSTI1 Normal Port7 Configuration - Priority |
| 1.3.6.1.4.1.4756.20.500.20.1.1074 | ColumnnidMSTI1Port8PathCostLocal | read-write | current | NID Series card MSTI Port Configuration: MSTI1 Normal Port8 Configuration - Path Cost Valid values are in the range 0 to 200000000. Setting 0 means Auto path c… |
| 1.3.6.1.4.1.4756.20.500.20.1.1075 | ColumnnidMSTI1Port8PriorityLocal | read-write | current | NID Series card MSTI Port Configuration: MSTI1 Normal Port8 Configuration - Priority |
| 1.3.6.1.4.1.4756.20.500.20.1.1076 | ColumnnidMSTI2AggregatedPathCostLocal | read-write | current | NID Series card MSTI Port Configuration: MSTI2 Aggregated Ports Configuration - Path Cost Valid values are in the range 0 to 200000000. Setting 0 means Auto pa… |
| 1.3.6.1.4.1.4756.20.500.20.1.1077 | ColumnnidMSTI2AggregatedPriorityLocal | read-write | current | NID Series card MSTI Port Configuration: MSTI2 Aggregated Ports Configuration - Priority |
| 1.3.6.1.4.1.4756.20.500.20.1.1078 | ColumnnidMSTI2Port1PathCostLocal | read-write | current | NID Series card MSTI Port Configuration: MSTI2 Normal Port1 Configuration - Path Cost Valid values are in the range 0 to 200000000. Setting 0 means Auto path c… |
| 1.3.6.1.4.1.4756.20.500.20.1.1079 | ColumnnidMSTI2Port1PriorityLocal | read-write | current | NID Series card MSTI Port Configuration: MSTI2 Normal Port1 Configuration - Priority |
| 1.3.6.1.4.1.4756.20.500.20.1.1080 | ColumnnidMSTI2Port2PathCostLocal | read-write | current | NID Series card MSTI Port Configuration: MSTI2 Normal Port2 Configuration - Path Cost Valid values are in the range 0 to 200000000. Setting 0 means Auto path c… |
| 1.3.6.1.4.1.4756.20.500.20.1.1081 | ColumnnidMSTI2Port2PriorityLocal | read-write | current | NID Series card MSTI Port Configuration: MSTI2 Normal Port2 Configuration - Priority |
| 1.3.6.1.4.1.4756.20.500.20.1.1082 | ColumnnidMSTI2Port3PathCostLocal | read-write | current | NID Series card MSTI Port Configuration: MSTI2 Normal Port3 Configuration - Path Cost Valid values are in the range 0 to 200000000. Setting 0 means Auto path c… |
| 1.3.6.1.4.1.4756.20.500.20.1.1083 | ColumnnidMSTI2Port3PriorityLocal | read-write | current | NID Series card MSTI Port Configuration: MSTI2 Normal Port3 Configuration - Priority |
| 1.3.6.1.4.1.4756.20.500.20.1.1084 | ColumnnidMSTI2Port4PathCostLocal | read-write | current | NID Series card MSTI Port Configuration: MSTI2 Normal Port4 Configuration - Path Cost Valid values are in the range 0 to 200000000. Setting 0 means Auto path c… |
| 1.3.6.1.4.1.4756.20.500.20.1.1085 | ColumnnidMSTI2Port4PriorityLocal | read-write | current | NID Series card MSTI Port Configuration: MSTI2 Normal Port4 Configuration - Priority |
| 1.3.6.1.4.1.4756.20.500.20.1.1086 | ColumnnidMSTI2Port5PathCostLocal | read-write | current | NID Series card MSTI Port Configuration: MSTI2 Normal Port5 Configuration - Path Cost Valid values are in the range 0 to 200000000. Setting 0 means Auto path c… |
| 1.3.6.1.4.1.4756.20.500.20.1.1087 | ColumnnidMSTI2Port5PriorityLocal | read-write | current | NID Series card MSTI Port Configuration: MSTI2 Normal Port5 Configuration - Priority |
| 1.3.6.1.4.1.4756.20.500.20.1.1088 | ColumnnidMSTI2Port6PathCostLocal | read-write | current | NID Series card MSTI Port Configuration: MSTI2 Normal Port6 Configuration - Path Cost Valid values are in the range 0 to 200000000. Setting 0 means Auto path c… |
| 1.3.6.1.4.1.4756.20.500.20.1.1089 | ColumnnidMSTI2Port6PriorityLocal | read-write | current | NID Series card MSTI Port Configuration: MSTI2 Normal Port6 Configuration - Priority |
| 1.3.6.1.4.1.4756.20.500.20.1.1090 | ColumnnidMSTI2Port7PathCostLocal | read-write | current | NID Series card MSTI Port Configuration: MSTI2 Normal Port7 Configuration - Path Cost Valid values are in the range 0 to 200000000. Setting 0 means Auto path c… |
| 1.3.6.1.4.1.4756.20.500.20.1.1091 | ColumnnidMSTI2Port7PriorityLocal | read-write | current | NID Series card MSTI Port Configuration: MSTI2 Normal Port7 Configuration - Priority |
| 1.3.6.1.4.1.4756.20.500.20.1.1092 | ColumnnidMSTI2Port8PathCostLocal | read-write | current | NID Series card MSTI Port Configuration: MSTI2 Normal Port8 Configuration - Path Cost Valid values are in the range 0 to 200000000. Setting 0 means Auto path c… |
| 1.3.6.1.4.1.4756.20.500.20.1.1093 | ColumnnidMSTI2Port8PriorityLocal | read-write | current | NID Series card MSTI Port Configuration: MSTI2 Normal Port8 Configuration - Priority |
| 1.3.6.1.4.1.4756.20.500.20.1.1094 | ColumnnidMSTI3AggregatedPathCostLocal | read-write | current | NID Series card MSTI Port Configuration: MSTI3 Aggregated Ports Configuration - Path Cost Valid values are in the range 0 to 200000000. Setting 0 means Auto pa… |
| 1.3.6.1.4.1.4756.20.500.20.1.1095 | ColumnnidMSTI3AggregatedPriorityLocal | read-write | current | NID Series card MSTI Port Configuration: MSTI3 Aggregated Ports Configuration - Priority |
| 1.3.6.1.4.1.4756.20.500.20.1.1096 | ColumnnidMSTI3Port1PathCostLocal | read-write | current | NID Series card MSTI Port Configuration: MSTI3 Normal Port1 Configuration - Path Cost Valid values are in the range 0 to 200000000. Setting 0 means Auto path c… |
| 1.3.6.1.4.1.4756.20.500.20.1.1097 | ColumnnidMSTI3Port1PriorityLocal | read-write | current | NID Series card MSTI Port Configuration: MSTI3 Normal Port1 Configuration - Priority |
| 1.3.6.1.4.1.4756.20.500.20.1.1098 | ColumnnidMSTI3Port2PathCostLocal | read-write | current | NID Series card MSTI Port Configuration: MSTI3 Normal Port2 Configuration - Path Cost Valid values are in the range 0 to 200000000. Setting 0 means Auto path c… |
| 1.3.6.1.4.1.4756.20.500.20.1.1099 | ColumnnidMSTI3Port2PriorityLocal | read-write | current | NID Series card MSTI Port Configuration: MSTI3 Normal Port2 Configuration - Priority |
| 1.3.6.1.4.1.4756.20.500.20.1.1100 | ColumnnidMSTI3Port3PathCostLocal | read-write | current | NID Series card MSTI Port Configuration: MSTI1 Normal Port3 Configuration - Path Cost Valid values are in the range 0 to 200000000. Setting 0 means Auto path c… |
| 1.3.6.1.4.1.4756.20.500.20.1.1101 | ColumnnidMSTI3Port3PriorityLocal | read-write | current | NID Series card MSTI Port Configuration: MSTI3 Normal Port3 Configuration - Priority |
| 1.3.6.1.4.1.4756.20.500.20.1.1102 | ColumnnidMSTI3Port4PathCostLocal | read-write | current | NID Series card MSTI Port Configuration: MSTI3 Normal Port4 Configuration - Path Cost Valid values are in the range 0 to 200000000. Setting 0 means Auto path c… |
| 1.3.6.1.4.1.4756.20.500.20.1.1103 | ColumnnidMSTI3Port4PriorityLocal | read-write | current | NID Series card MSTI Port Configuration: MSTI3 Normal Port4 Configuration - Priority |
| 1.3.6.1.4.1.4756.20.500.20.1.1104 | ColumnnidMSTI3Port5PathCostLocal | read-write | current | NID Series card MSTI Port Configuration: MSTI3 Normal Port5 Configuration - Path Cost Valid values are in the range 0 to 200000000. Setting 0 means Auto path c… |
| 1.3.6.1.4.1.4756.20.500.20.1.1105 | ColumnnidMSTI3Port5PriorityLocal | read-write | current | NID Series card MSTI Port Configuration: MSTI3 Normal Port5 Configuration - Priority |
| 1.3.6.1.4.1.4756.20.500.20.1.1106 | ColumnnidMSTI3Port6PathCostLocal | read-write | current | NID Series card MSTI Port Configuration: MSTI3 Normal Port6 Configuration - Path Cost Valid values are in the range 0 to 200000000. Setting 0 means Auto path c… |
| 1.3.6.1.4.1.4756.20.500.20.1.1107 | ColumnnidMSTI3Port6PriorityLocal | read-write | current | NID Series card MSTI Port Configuration: MSTI3 Normal Port6 Configuration - Priority |
| 1.3.6.1.4.1.4756.20.500.20.1.1108 | ColumnnidMSTI3Port7PathCostLocal | read-write | current | NID Series card MSTI Port Configuration: MSTI3 Normal Port7 Configuration - Path Cost Valid values are in the range 0 to 200000000. Setting 0 means Auto path c… |
| 1.3.6.1.4.1.4756.20.500.20.1.1109 | ColumnnidMSTI3Port7PriorityLocal | read-write | current | NID Series card MSTI Port Configuration: MSTI3 Normal Port7 Configuration - Priority |
| 1.3.6.1.4.1.4756.20.500.20.1.1110 | ColumnnidMSTI3Port8PathCostLocal | read-write | current | NID Series card MSTI Port Configuration: MSTI3 Normal Port8 Configuration - Path Cost Valid values are in the range 0 to 200000000. Setting 0 means Auto path c… |
| 1.3.6.1.4.1.4756.20.500.20.1.1111 | ColumnnidMSTI3Port8PriorityLocal | read-write | current | NID Series card MSTI Port Configuration: MSTI3 Normal Port8 Configuration - Priority |
| 1.3.6.1.4.1.4756.20.500.20.1.1112 | ColumnnidMSTI4AggregatedPathCostLocal | read-write | current | NID Series card MSTI Port Configuration: MSTI4 Aggregated Ports Configuration - Path Cost Valid values are in the range 0 to 200000000. Setting 0 means Auto pa… |
| 1.3.6.1.4.1.4756.20.500.20.1.1113 | ColumnnidMSTI4AggregatedPriorityLocal | read-write | current | NID Series card MSTI Port Configuration: MSTI4 Aggregated Ports Configuration - Priority |
| 1.3.6.1.4.1.4756.20.500.20.1.1114 | ColumnnidMSTI4Port1PathCostLocal | read-write | current | NID Series card MSTI Port Configuration: MSTI4 Normal Port1 Configuration - Path Cost Valid values are in the range 0 to 200000000. Setting 0 means Auto path c… |
| 1.3.6.1.4.1.4756.20.500.20.1.1115 | ColumnnidMSTI4Port1PriorityLocal | read-write | current | NID Series card MSTI Port Configuration: MSTI4 Normal Port1 Configuration - Priority |
| 1.3.6.1.4.1.4756.20.500.20.1.1116 | ColumnnidMSTI4Port2PathCostLocal | read-write | current | NID Series card MSTI Port Configuration: MSTI4 Normal Port2 Configuration - Path Cost Valid values are in the range 0 to 200000000. Setting 0 means Auto path c… |
| 1.3.6.1.4.1.4756.20.500.20.1.1117 | ColumnnidMSTI4Port2PriorityLocal | read-write | current | NID Series card MSTI Port Configuration: MSTI4 Normal Port2 Configuration - Priority |
| 1.3.6.1.4.1.4756.20.500.20.1.1118 | ColumnnidMSTI4Port3PathCostLocal | read-write | current | NID Series card MSTI Port Configuration: MSTI1 Normal Port3 Configuration - Path Cost Valid values are in the range 0 to 200000000. Setting 0 means Auto path c… |
| 1.3.6.1.4.1.4756.20.500.20.1.1119 | ColumnnidMSTI4Port3PriorityLocal | read-write | current | NID Series card MSTI Port Configuration: MSTI4 Normal Port3 Configuration - Priority |
| 1.3.6.1.4.1.4756.20.500.20.1.1120 | ColumnnidMSTI4Port4PathCostLocal | read-write | current | NID Series card MSTI Port Configuration: MSTI4 Normal Port4 Configuration - Path Cost Valid values are in the range 0 to 200000000. Setting 0 means Auto path c… |
| 1.3.6.1.4.1.4756.20.500.20.1.1121 | ColumnnidMSTI4Port4PriorityLocal | read-write | current | NID Series card MSTI Port Configuration: MSTI4 Normal Port4 Configuration - Priority |
| 1.3.6.1.4.1.4756.20.500.20.1.1122 | ColumnnidMSTI4Port5PathCostLocal | read-write | current | NID Series card MSTI Port Configuration: MSTI4 Normal Port5 Configuration - Path Cost Valid values are in the range 0 to 200000000. Setting 0 means Auto path c… |
| 1.3.6.1.4.1.4756.20.500.20.1.1123 | ColumnnidMSTI4Port5PriorityLocal | read-write | current | NID Series card MSTI Port Configuration: MSTI4 Normal Port5 Configuration - Priority |
| 1.3.6.1.4.1.4756.20.500.20.1.1124 | ColumnnidMSTI4Port6PathCostLocal | read-write | current | NID Series card MSTI Port Configuration: MSTI4 Normal Port4 Configuration - Path Cost Valid values are in the range 0 to 200000000. Setting 0 means Auto path c… |
| 1.3.6.1.4.1.4756.20.500.20.1.1125 | ColumnnidMSTI4Port6PriorityLocal | read-write | current | NID Series card MSTI Port Configuration: MSTI4 Normal Port6 Configuration - Priority |
| 1.3.6.1.4.1.4756.20.500.20.1.1126 | ColumnnidMSTI4Port7PathCostLocal | read-write | current | NID Series card MSTI Port Configuration: MSTI4 Normal Port7 Configuration - Path Cost Valid values are in the range 0 to 200000000. Setting 0 means Auto path c… |
| 1.3.6.1.4.1.4756.20.500.20.1.1127 | ColumnnidMSTI4Port7PriorityLocal | read-write | current | NID Series card MSTI Port Configuration: MSTI4 Normal Port7 Configuration - Priority |
| 1.3.6.1.4.1.4756.20.500.20.1.1128 | ColumnnidMSTI4Port8PathCostLocal | read-write | current | NID Series card MSTI Port Configuration: MSTI4 Normal Port8 Configuration - Path Cost Valid values are in the range 0 to 200000000. Setting 0 means Auto path c… |
| 1.3.6.1.4.1.4756.20.500.20.1.1129 | ColumnnidMSTI4Port8PriorityLocal | read-write | current | NID Series card MSTI Port Configuration: MSTI4 Normal Port8 Configuration - Priority |
| 1.3.6.1.4.1.4756.20.500.20.1.1130 | ColumnnidMSTI5AggregatedPathCostLocal | read-write | current | NID Series card MSTI Port Configuration: MSTI5 Aggregated Ports Configuration - Path Cost Valid values are in the range 0 to 200000000. Setting 0 means Auto pa… |
| 1.3.6.1.4.1.4756.20.500.20.1.1131 | ColumnnidMSTI5AggregatedPriorityLocal | read-write | current | NID Series card MSTI Port Configuration: MSTI5 Aggregated Ports Configuration - Priority |
| 1.3.6.1.4.1.4756.20.500.20.1.1132 | ColumnnidMSTI5Port1PathCostLocal | read-write | current | NID Series card MSTI Port Configuration: MSTI5 Normal Port1 Configuration - Path Cost Valid values are in the range 0 to 200000000. Setting 0 means Auto path c… |
| 1.3.6.1.4.1.4756.20.500.20.1.1133 | ColumnnidMSTI5Port1PriorityLocal | read-write | current | NID Series card MSTI Port Configuration: MSTI5 Normal Port1 Configuration - Priority |
| 1.3.6.1.4.1.4756.20.500.20.1.1134 | ColumnnidMSTI5Port2PathCostLocal | read-write | current | NID Series card MSTI Port Configuration: MSTI5 Normal Port2 Configuration - Path Cost Valid values are in the range 0 to 200000000. Setting 0 means Auto path c… |
| 1.3.6.1.4.1.4756.20.500.20.1.1135 | ColumnnidMSTI5Port2PriorityLocal | read-write | current | NID Series card MSTI Port Configuration: MSTI5 Normal Port2 Configuration - Priority |
| 1.3.6.1.4.1.4756.20.500.20.1.1136 | ColumnnidMSTI5Port3PathCostLocal | read-write | current | NID Series card MSTI Port Configuration: MSTI5 Normal Port3 Configuration - Path Cost Valid values are in the range 0 to 200000000. Setting 0 means Auto path c… |
| 1.3.6.1.4.1.4756.20.500.20.1.1137 | ColumnnidMSTI5Port3PriorityLocal | read-write | current | NID Series card MSTI Port Configuration: MSTI5 Normal Port3 Configuration - Priority |
| 1.3.6.1.4.1.4756.20.500.20.1.1138 | ColumnnidMSTI5Port4PathCostLocal | read-write | current | NID Series card MSTI Port Configuration: MSTI5 Normal Port4 Configuration - Path Cost Valid values are in the range 0 to 200000000. Setting 0 means Auto path c… |
| 1.3.6.1.4.1.4756.20.500.20.1.1139 | ColumnnidMSTI5Port4PriorityLocal | read-write | current | NID Series card MSTI Port Configuration: MSTI5 Normal Port4 Configuration - Priority |
| 1.3.6.1.4.1.4756.20.500.20.1.1140 | ColumnnidMSTI5Port5PathCostLocal | read-write | current | NID Series card MSTI Port Configuration: MSTI5 Normal Port5 Configuration - Path Cost Valid values are in the range 0 to 200000000. Setting 0 means Auto path c… |
| 1.3.6.1.4.1.4756.20.500.20.1.1141 | ColumnnidMSTI5Port5PriorityLocal | read-write | current | NID Series card MSTI Port Configuration: MSTI5 Normal Port5 Configuration - Priority |
| 1.3.6.1.4.1.4756.20.500.20.1.1142 | ColumnnidMSTI5Port6PathCostLocal | read-write | current | NID Series card MSTI Port Configuration: MSTI5 Normal Port6 Configuration - Path Cost Valid values are in the range 0 to 200000000. Setting 0 means Auto path c… |
| 1.3.6.1.4.1.4756.20.500.20.1.1143 | ColumnnidMSTI5Port6PriorityLocal | read-write | current | NID Series card MSTI Port Configuration: MSTI5 Normal Port6 Configuration - Priority |
| 1.3.6.1.4.1.4756.20.500.20.1.1144 | ColumnnidMSTI5Port7PathCostLocal | read-write | current | NID Series card MSTI Port Configuration: MSTI5 Normal Port7 Configuration - Path Cost Valid values are in the range 0 to 200000000. Setting 0 means Auto path c… |
| 1.3.6.1.4.1.4756.20.500.20.1.1145 | ColumnnidMSTI5Port7PriorityLocal | read-write | current | NID Series card MSTI Port Configuration: MSTI5 Normal Port7 Configuration - Priority |
| 1.3.6.1.4.1.4756.20.500.20.1.1146 | ColumnnidMSTI5Port8PathCostLocal | read-write | current | NID Series card MSTI Port Configuration: MSTI5 Normal Port8 Configuration - Path Cost Valid values are in the range 0 to 200000000. Setting 0 means Auto path c… |
| 1.3.6.1.4.1.4756.20.500.20.1.1147 | ColumnnidMSTI5Port8PriorityLocal | read-write | current | NID Series card MSTI Port Configuration: MSTI5 Normal Port8 Configuration - Priority |
| 1.3.6.1.4.1.4756.20.500.20.1.1148 | ColumnnidMSTI6AggregatedPathCostLocal | read-write | current | NID Series card MSTI Port Configuration: MSTI6 Aggregated Ports Configuration - Path Cost Valid values are in the range 0 to 200000000. Setting 0 means Auto pa… |
| 1.3.6.1.4.1.4756.20.500.20.1.1149 | ColumnnidMSTI6AggregatedPriorityLocal | read-write | current | NID Series card MSTI Port Configuration: MSTI6 Aggregated Ports Configuration - Priority |
| 1.3.6.1.4.1.4756.20.500.20.1.1150 | ColumnnidMSTI6Port1PathCostLocal | read-write | current | NID Series card MSTI Port Configuration: MSTI6 Normal Port1 Configuration - Path Cost Valid values are in the range 0 to 200000000. Setting 0 means Auto path c… |
| 1.3.6.1.4.1.4756.20.500.20.1.1151 | ColumnnidMSTI6Port1PriorityLocal | read-write | current | NID Series card MSTI Port Configuration: MSTI6 Normal Port1 Configuration - Priority |
| 1.3.6.1.4.1.4756.20.500.20.1.1152 | ColumnnidMSTI6Port2PathCostLocal | read-write | current | NID Series card MSTI Port Configuration: MSTI6 Normal Port2 Configuration - Path Cost Valid values are in the range 0 to 200000000. Setting 0 means Auto path c… |
| 1.3.6.1.4.1.4756.20.500.20.1.1153 | ColumnnidMSTI6Port2PriorityLocal | read-write | current | NID Series card MSTI Port Configuration: MSTI6 Normal Port2 Configuration - Priority |
| 1.3.6.1.4.1.4756.20.500.20.1.1154 | ColumnnidMSTI6Port3PathCostLocal | read-write | current | NID Series card MSTI Port Configuration: MSTI6 Normal Port3 Configuration - Path Cost Valid values are in the range 0 to 200000000. Setting 0 means Auto path c… |
| 1.3.6.1.4.1.4756.20.500.20.1.1155 | ColumnnidMSTI6Port3PriorityLocal | read-write | current | NID Series card MSTI Port Configuration: MSTI6 Normal Port3 Configuration - Priority |
| 1.3.6.1.4.1.4756.20.500.20.1.1156 | ColumnnidMSTI6Port4PathCostLocal | read-write | current | NID Series card MSTI Port Configuration: MSTI6 Normal Port4 Configuration - Path Cost Valid values are in the range 0 to 200000000. Setting 0 means Auto path c… |
| 1.3.6.1.4.1.4756.20.500.20.1.1157 | ColumnnidMSTI6Port4PriorityLocal | read-write | current | NID Series card MSTI Port Configuration: MSTI6 Normal Port4 Configuration - Priority |
| 1.3.6.1.4.1.4756.20.500.20.1.1158 | ColumnnidMSTI6Port5PathCostLocal | read-write | current | NID Series card MSTI Port Configuration: MSTI6 Normal Port5 Configuration - Path Cost Valid values are in the range 0 to 200000000. Setting 0 means Auto path c… |
| 1.3.6.1.4.1.4756.20.500.20.1.1159 | ColumnnidMSTI6Port5PriorityLocal | read-write | current | NID Series card MSTI Port Configuration: MSTI6 Normal Port6 Configuration - Priority |
| 1.3.6.1.4.1.4756.20.500.20.1.1160 | ColumnnidMSTI6Port6PathCostLocal | read-write | current | NID Series card MSTI Port Configuration: MSTI6 Normal Port6 Configuration - Path Cost Valid values are in the range 0 to 200000000. Setting 0 means Auto path c… |
| 1.3.6.1.4.1.4756.20.500.20.1.1161 | ColumnnidMSTI6Port6PriorityLocal | read-write | current | NID Series card MSTI Port Configuration: MSTI6 Normal Port6 Configuration - Priority |
| 1.3.6.1.4.1.4756.20.500.20.1.1162 | ColumnnidMSTI6Port7PathCostLocal | read-write | current | NID Series card MSTI Port Configuration: MSTI6 Normal Port7 Configuration - Path Cost Valid values are in the range 0 to 200000000. Setting 0 means Auto path c… |
| 1.3.6.1.4.1.4756.20.500.20.1.1163 | ColumnnidMSTI6Port7PriorityLocal | read-write | current | NID Series card MSTI Port Configuration: MSTI6 Normal Port6 Configuration - Priority |
| 1.3.6.1.4.1.4756.20.500.20.1.1164 | ColumnnidMSTI6Port8PathCostLocal | read-write | current | NID Series card MSTI Port Configuration: MSTI6 Normal Port8 Configuration - Path Cost Valid values are in the range 0 to 200000000. Setting 0 means Auto path c… |
| 1.3.6.1.4.1.4756.20.500.20.1.1165 | ColumnnidMSTI6Port8PriorityLocal | read-write | current | NID Series card MSTI Port Configuration: MSTI6 Normal Port8 Configuration - Priority |
| 1.3.6.1.4.1.4756.20.500.20.1.1166 | ColumnnidMSTI7AggregatedPathCostLocal | read-write | current | NID Series card MSTI Port Configuration: MSTI7 Aggregated Ports Configuration - Path Cost Valid values are in the range 0 to 200000000. Setting 0 means Auto pa… |
| 1.3.6.1.4.1.4756.20.500.20.1.1167 | ColumnnidMSTI7AggregatedPriorityLocal | read-write | current | NID Series card MSTI Port Configuration: MSTI7 Aggregated Ports Configuration - Priority |
| 1.3.6.1.4.1.4756.20.500.20.1.1168 | ColumnnidMSTI7Port1PathCostLocal | read-write | current | NID Series card MSTI Port Configuration: MSTI1 Normal Port1 Configuration - Path Cost Valid values are in the range 0 to 200000000. Setting 0 means Auto path c… |
| 1.3.6.1.4.1.4756.20.500.20.1.1169 | ColumnnidMSTI7Port1PriorityLocal | read-write | current | NID Series card MSTI Port Configuration: MSTI1 Normal Port1 Configuration - Priority |
| 1.3.6.1.4.1.4756.20.500.20.1.1170 | ColumnnidMSTI7Port2PathCostLocal | read-write | current | NID Series card MSTI Port Configuration: MSTI7 Normal Port2 Configuration - Path Cost Valid values are in the range 0 to 200000000. Setting 0 means Auto path c… |
| 1.3.6.1.4.1.4756.20.500.20.1.1171 | ColumnnidMSTI7Port2PriorityLocal | read-write | current | NID Series card MSTI Port Configuration: MSTI7 Normal Port2 Configuration - Priority |
| 1.3.6.1.4.1.4756.20.500.20.1.1172 | ColumnnidMSTI7Port3PathCostLocal | read-write | current | NID Series card MSTI Port Configuration: MSTI7 Normal Port3 Configuration - Path Cost Valid values are in the range 0 to 200000000. Setting 0 means Auto path c… |
| 1.3.6.1.4.1.4756.20.500.20.1.1173 | ColumnnidMSTI7Port3PriorityLocal | read-write | current | NID Series card MSTI Port Configuration: MSTI7 Normal Port3 Configuration - Priority |
| 1.3.6.1.4.1.4756.20.500.20.1.1174 | ColumnnidMSTI7Port4PathCostLocal | read-write | current | NID Series card MSTI Port Configuration: MSTI7 Normal Port4 Configuration - Path Cost Valid values are in the range 0 to 200000000. Setting 0 means Auto path c… |
| 1.3.6.1.4.1.4756.20.500.20.1.1175 | ColumnnidMSTI7Port4PriorityLocal | read-write | current | NID Series card MSTI Port Configuration: MSTI7 Normal Port4 Configuration - Priority |
| 1.3.6.1.4.1.4756.20.500.20.1.1176 | ColumnnidMSTI7Port5PathCostLocal | read-write | current | NID Series card MSTI Port Configuration: MSTI7 Normal Port5 Configuration - Path Cost Valid values are in the range 0 to 200000000. Setting 0 means Auto path c… |
| 1.3.6.1.4.1.4756.20.500.20.1.1177 | ColumnnidMSTI7Port5PriorityLocal | read-write | current | NID Series card MSTI Port Configuration: MSTI7 Normal Port5 Configuration - Priority |
| 1.3.6.1.4.1.4756.20.500.20.1.1178 | ColumnnidMSTI7Port6PathCostLocal | read-write | current | NID Series card MSTI Port Configuration: MSTI7 Normal Port6 Configuration - Path Cost Valid values are in the range 0 to 200000000. Setting 0 means Auto path c… |
| 1.3.6.1.4.1.4756.20.500.20.1.1179 | ColumnnidMSTI7Port6PriorityLocal | read-write | current | NID Series card MSTI Port Configuration: MSTI7 Normal Port6 Configuration - Priority |
| 1.3.6.1.4.1.4756.20.500.20.1.1180 | ColumnnidMSTI7Port7PathCostLocal | read-write | current | NID Series card MSTI Port Configuration: MSTI7 Normal Port7 Configuration - Path Cost Valid values are in the range 0 to 200000000. Setting 0 means Auto path c… |
| 1.3.6.1.4.1.4756.20.500.20.1.1181 | ColumnnidMSTI7Port7PriorityLocal | read-write | current | NID Series card MSTI Port Configuration: MSTI7 Normal Port7 Configuration - Priority |
| 1.3.6.1.4.1.4756.20.500.20.1.1182 | ColumnnidMSTI7Port8PathCostLocal | read-write | current | NID Series card MSTI Port Configuration: MSTI7 Normal Port8 Configuration - Path Cost Valid values are in the range 0 to 200000000. Setting 0 means Auto path c… |
| 1.3.6.1.4.1.4756.20.500.20.1.1183 | ColumnnidMSTI7Port8PriorityLocal | read-write | current | NID Series card MSTI Port Configuration: MSTI7 Normal Port8 Configuration - Priority |
| 1.3.6.1.4.1.4756.20.500.20.1.1184 | ColumnnidMSTI8AggregatedPathCostLocal | read-write | current | NID Series card MSTI Port Configuration: MSTI8 Aggregated Ports Configuration - Path Cost Valid values are in the range 0 to 200000000. Setting 0 means Auto pa… |
| 1.3.6.1.4.1.4756.20.500.20.1.1185 | ColumnnidMSTI8AggregatedPriorityLocal | read-write | current | NID Series card MSTI Port Configuration: MSTI7 Aggregated Ports Configuration - Priority |
| 1.3.6.1.4.1.4756.20.500.20.1.1186 | ColumnnidMSTI8Port1PathCostLocal | read-write | current | NID Series card MSTI Port Configuration: MSTI8 Normal Port1 Configuration - Path Cost Valid values are in the range 0 to 200000000. Setting 0 means Auto path c… |
| 1.3.6.1.4.1.4756.20.500.20.1.1187 | ColumnnidMSTI8Port1PriorityLocal | read-write | current | NID Series card MSTI Port Configuration: MSTI8 Normal Port1 Configuration - Priority |
| 1.3.6.1.4.1.4756.20.500.20.1.1188 | ColumnnidMSTI8Port2PathCostLocal | read-write | current | NID Series card MSTI Port Configuration: MSTI8 Normal Port2 Configuration - Path Cost Valid values are in the range 0 to 200000000. Setting 0 means Auto path c… |
| 1.3.6.1.4.1.4756.20.500.20.1.1189 | ColumnnidMSTI8Port2PriorityLocal | read-write | current | NID Series card MSTI Port Configuration: MSTI8 Normal Port2 Configuration - Priority |
| 1.3.6.1.4.1.4756.20.500.20.1.1190 | ColumnnidMSTI8Port3PathCostLocal | read-write | current | NID Series card MSTI Port Configuration: MSTI8 Normal Port3 Configuration - Path Cost Valid values are in the range 0 to 200000000. Setting 0 means Auto path c… |
| 1.3.6.1.4.1.4756.20.500.20.1.1191 | ColumnnidMSTI8Port3PriorityLocal | read-write | current | NID Series card MSTI Port Configuration: MSTI8 Normal Port3 Configuration - Priority |
| 1.3.6.1.4.1.4756.20.500.20.1.1192 | ColumnnidMSTI8Port4PathCostLocal | read-write | current | NID Series card MSTI Port Configuration: MSTI8 Normal Port4 Configuration - Path Cost Valid values are in the range 0 to 200000000. Setting 0 means Auto path c… |
| 1.3.6.1.4.1.4756.20.500.20.1.1193 | ColumnnidMSTI8Port4PriorityLocal | read-write | current | NID Series card MSTI Port Configuration: MSTI8 Normal Port4 Configuration - Priority |
| 1.3.6.1.4.1.4756.20.500.20.1.1194 | ColumnnidMSTI8Port5PathCostLocal | read-write | current | NID Series card MSTI Port Configuration: MSTI8 Normal Port5 Configuration - Path Cost Valid values are in the range 0 to 200000000. Setting 0 means Auto path c… |
| 1.3.6.1.4.1.4756.20.500.20.1.1195 | ColumnnidMSTI8Port5PriorityLocal | read-write | current | NID Series card MSTI Port Configuration: MSTI8 Normal Port5 Configuration - Priority |
| 1.3.6.1.4.1.4756.20.500.20.1.1196 | ColumnnidMSTI8Port6PathCostLocal | read-write | current | NID Series card MSTI Port Configuration: MSTI8 Normal Port6 Configuration - Path Cost Valid values are in the range 0 to 200000000. Setting 0 means Auto path c… |
| 1.3.6.1.4.1.4756.20.500.20.1.1197 | ColumnnidMSTI8Port6PriorityLocal | read-write | current | NID Series card MSTI Port Configuration: MSTI8 Normal Port6 Configuration - Priority |
| 1.3.6.1.4.1.4756.20.500.20.1.1198 | ColumnnidMSTI8Port7PathCostLocal | read-write | current | NID Series card MSTI Port Configuration: MSTI8 Normal Port7 Configuration - Path Cost Valid values are in the range 0 to 200000000. Setting 0 means Auto path c… |
| 1.3.6.1.4.1.4756.20.500.20.1.1199 | ColumnnidMSTI8Port7PriorityLocal | read-write | current | NID Series card MSTI Port Configuration: MSTI8 Normal Port7 Configuration - Priority |
| 1.3.6.1.4.1.4756.20.500.20.1.1200 | ColumnnidMSTI8Port8PathCostLocal | read-write | current | NID Series card MSTI Port Configuration: MSTI7 Normal Port8 Configuration - Path Cost Valid values are in the range 0 to 200000000. Setting 0 means Auto path c… |
| 1.3.6.1.4.1.4756.20.500.20.1.1201 | ColumnnidMSTI8Port8PriorityLocal | read-write | current | NID Series card MSTI Port Configuration: MSTI8 Normal Port8 Configuration - Priority |
| 1.3.6.1.4.1.4756.20.500.20.1.1202 | ColumnnidMSTI9AggregatedPathCostLocal | read-write | current | NID Series card MSTI Port Configuration: MSTI9 Aggregated Ports Configuration - Path Cost Valid values are in the range 0 to 200000000. Setting 0 means Auto pa… |
| 1.3.6.1.4.1.4756.20.500.20.1.1203 | ColumnnidMSTI9AggregatedPriorityLocal | read-write | current | NID Series card MSTI Port Configuration: MSTI9 Aggregated Ports Configuration - Priority |
| 1.3.6.1.4.1.4756.20.500.20.1.1204 | ColumnnidMSTI9Port1PathCostLocal | read-write | current | NID Series card MSTI Port Configuration: MSTI9 Normal Port1 Configuration - Path Cost Valid values are in the range 0 to 200000000. Setting 0 means Auto path c… |
| 1.3.6.1.4.1.4756.20.500.20.1.1205 | ColumnnidMSTI9Port1PriorityLocal | read-write | current | NID Series card MSTI Port Configuration: MSTI9 Normal Port1 Configuration - Priority |
| 1.3.6.1.4.1.4756.20.500.20.1.1206 | ColumnnidMSTI9Port2PathCostLocal | read-write | current | NID Series card MSTI Port Configuration: MSTI9 Normal Port2 Configuration - Path Cost Valid values are in the range 0 to 200000000. Setting 0 means Auto path c… |
| 1.3.6.1.4.1.4756.20.500.20.1.1207 | ColumnnidMSTI9Port2PriorityLocal | read-write | current | NID Series card MSTI Port Configuration: MSTI8 Normal Port2 Configuration - Priority |
| 1.3.6.1.4.1.4756.20.500.20.1.1208 | ColumnnidMSTI9Port3PathCostLocal | read-write | current | NID Series card MSTI Port Configuration: MSTI8 Normal Port3 Configuration - Path Cost Valid values are in the range 0 to 200000000. Setting 0 means Auto path c… |
| 1.3.6.1.4.1.4756.20.500.20.1.1209 | ColumnnidMSTI9Port3PriorityLocal | read-write | current | NID Series card MSTI Port Configuration: MSTI9 Normal Port3 Configuration - Priority |
| 1.3.6.1.4.1.4756.20.500.20.1.1210 | ColumnnidMSTI9Port4PathCostLocal | read-write | current | NID Series card MSTI Port Configuration: MSTI9 Normal Port4 Configuration - Path Cost Valid values are in the range 0 to 200000000. Setting 0 means Auto path c… |
| 1.3.6.1.4.1.4756.20.500.20.1.1211 | ColumnnidMSTI9Port4PriorityLocal | read-write | current | NID Series card MSTI Port Configuration: MSTI9 Normal Port4 Configuration - Priority |
| 1.3.6.1.4.1.4756.20.500.20.1.1212 | ColumnnidMSTI9Port5PathCostLocal | read-write | current | NID Series card MSTI Port Configuration: MSTI9 Normal Port5 Configuration - Path Cost Valid values are in the range 0 to 200000000. Setting 0 means Auto path c… |
| 1.3.6.1.4.1.4756.20.500.20.1.1213 | ColumnnidMSTI9Port5PriorityLocal | read-write | current | NID Series card MSTI Port Configuration: MSTI9 Normal Port5 Configuration - Priority |
| 1.3.6.1.4.1.4756.20.500.20.1.1214 | ColumnnidMSTI9Port6PathCostLocal | read-write | current | NID Series card MSTI Port Configuration: MSTI9 Normal Port6 Configuration - Path Cost Valid values are in the range 0 to 200000000. Setting 0 means Auto path c… |
| 1.3.6.1.4.1.4756.20.500.20.1.1215 | ColumnnidMSTI9Port6PriorityLocal | read-write | current | NID Series card MSTI Port Configuration: MSTI9 Normal Port6 Configuration - Priority |
| 1.3.6.1.4.1.4756.20.500.20.1.1216 | ColumnnidMSTI9Port7PathCostLocal | read-write | current | NID Series card MSTI Port Configuration: MSTI9 Normal Port7 Configuration - Path Cost Valid values are in the range 0 to 200000000. Setting 0 means Auto path c… |
| 1.3.6.1.4.1.4756.20.500.20.1.1217 | ColumnnidMSTI9Port7PriorityLocal | read-write | current | NID Series card MSTI Port Configuration: MSTI9 Normal Port7 Configuration - Priority |
| 1.3.6.1.4.1.4756.20.500.20.1.1218 | ColumnnidMSTI9Port8PathCostLocal | read-write | current | NID Series card MSTI Port Configuration: MSTI8 Normal Port8 Configuration - Path Cost Valid values are in the range 0 to 200000000. Setting 0 means Auto path c… |
| 1.3.6.1.4.1.4756.20.500.20.1.1219 | ColumnnidMSTI9Port8PriorityLocal | read-write | current | NID Series card MSTI Port Configuration: MSTI9 Normal Port8 Configuration - Priority |
| 1.3.6.1.4.1.4756.20.500.20.1.1220 | ColumnnidMSTI10AggregatedPathCostLocal | read-write | current | NID Series card MSTI Port Configuration: MSTI10 Aggregated Ports Configuration - Path Cost Valid values are in the range 0 to 200000000. Setting 0 means Auto p… |
| 1.3.6.1.4.1.4756.20.500.20.1.1221 | ColumnnidMSTI10AggregatedPriorityLocal | read-write | current | NID Series card MSTI Port Configuration: MSTI10 Aggregated Ports Configuration - Priority |
| 1.3.6.1.4.1.4756.20.500.20.1.1222 | ColumnnidMSTI10Port1PathCostLocal | read-write | current | NID Series card MSTI Port Configuration: MSTI10 Normal Port1 Configuration - Path Cost Valid values are in the range 0 to 200000000. Setting 0 means Auto path … |
| 1.3.6.1.4.1.4756.20.500.20.1.1223 | ColumnnidMSTI10Port1PriorityLocal | read-write | current | NID Series card MSTI Port Configuration: MSTI10 Normal Port1 Configuration - Priority |
| 1.3.6.1.4.1.4756.20.500.20.1.1224 | ColumnnidMSTI10Port2PathCostLocal | read-write | current | NID Series card MSTI Port Configuration: MSTI10 Normal Port2 Configuration - Path Cost Valid values are in the range 0 to 200000000. Setting 0 means Auto path … |
| 1.3.6.1.4.1.4756.20.500.20.1.1225 | ColumnnidMSTI10Port2PriorityLocal | read-write | current | NID Series card MSTI Port Configuration: MSTI8 Normal Port2 Configuration - Priority |
| 1.3.6.1.4.1.4756.20.500.20.1.1226 | ColumnnidMSTI10Port3PathCostLocal | read-write | current | NID Series card MSTI Port Configuration: MSTI8 Normal Port3 Configuration - Path Cost Valid values are in the range 0 to 200000000. Setting 0 means Auto path c… |
| 1.3.6.1.4.1.4756.20.500.20.1.1227 | ColumnnidMSTI10Port3PriorityLocal | read-write | current | NID Series card MSTI Port Configuration: MSTI10 Normal Port3 Configuration - Priority |
| 1.3.6.1.4.1.4756.20.500.20.1.1228 | ColumnnidMSTI10Port4PathCostLocal | read-write | current | NID Series card MSTI Port Configuration: MSTI10 Normal Port4 Configuration - Path Cost Valid values are in the range 0 to 200000000. Setting 0 means Auto path … |
| 1.3.6.1.4.1.4756.20.500.20.1.1229 | ColumnnidMSTI10Port4PriorityLocal | read-write | current | NID Series card MSTI Port Configuration: MSTI10 Normal Port4 Configuration - Priority |
| 1.3.6.1.4.1.4756.20.500.20.1.1230 | ColumnnidMSTI10Port5PathCostLocal | read-write | current | NID Series card MSTI Port Configuration: MSTI10 Normal Port5 Configuration - Path Cost Valid values are in the range 0 to 200000000. Setting 0 means Auto path … |
| 1.3.6.1.4.1.4756.20.500.20.1.1231 | ColumnnidMSTI10Port5PriorityLocal | read-write | current | NID Series card MSTI Port Configuration: MSTI10 Normal Port5 Configuration - Priority |
| 1.3.6.1.4.1.4756.20.500.20.1.1232 | ColumnnidMSTI10Port6PathCostLocal | read-write | current | NID Series card MSTI Port Configuration: MSTI10 Normal Port6 Configuration - Path Cost Valid values are in the range 0 to 200000000. Setting 0 means Auto path … |
| 1.3.6.1.4.1.4756.20.500.20.1.1233 | ColumnnidMSTI10Port6PriorityLocal | read-write | current | NID Series card MSTI Port Configuration: MSTI10 Normal Port6 Configuration - Priority |
| 1.3.6.1.4.1.4756.20.500.20.1.1234 | ColumnnidMSTI10Port7PathCostLocal | read-write | current | NID Series card MSTI Port Configuration: MSTI10 Normal Port7 Configuration - Path Cost Valid values are in the range 0 to 200000000. Setting 0 means Auto path … |
| 1.3.6.1.4.1.4756.20.500.20.1.1235 | ColumnnidMSTI10Port7PriorityLocal | read-write | current | NID Series card MSTI Port Configuration: MSTI10 Normal Port7 Configuration - Priority |
| 1.3.6.1.4.1.4756.20.500.20.1.1236 | ColumnnidMSTI10Port8PathCostLocal | read-write | current | NID Series card MSTI Port Configuration: MSTI8 Normal Port8 Configuration - Path Cost Valid values are in the range 0 to 200000000. Setting 0 means Auto path c… |
| 1.3.6.1.4.1.4756.20.500.20.1.1237 | ColumnnidMSTI10Port8PriorityLocal | read-write | current | NID Series card MSTI Port Configuration: MSTI10 Normal Port8 Configuration - Priority |
| 1.3.6.1.4.1.4756.20.500.20.1.1238 | ColumnnidMSTI11AggregatedPathCostLocal | read-write | current | NID Series card MSTI Port Configuration: MSTI11 Aggregated Ports Configuration - Path Cost Valid values are in the range 0 to 200000000. Setting 0 means Auto p… |
| 1.3.6.1.4.1.4756.20.500.20.1.1239 | ColumnnidMSTI11AggregatedPriorityLocal | read-write | current | NID Series card MSTI Port Configuration: MSTI11 Aggregated Ports Configuration - Priority |
| 1.3.6.1.4.1.4756.20.500.20.1.1240 | ColumnnidMSTI11Port1PathCostLocal | read-write | current | NID Series card MSTI Port Configuration: MSTI11 Normal Port1 Configuration - Path Cost Valid values are in the range 0 to 200000000. Setting 0 means Auto path … |
| 1.3.6.1.4.1.4756.20.500.20.1.1241 | ColumnnidMSTI11Port1PriorityLocal | read-write | current | NID Series card MSTI Port Configuration: MSTI11 Normal Port1 Configuration - Priority |
| 1.3.6.1.4.1.4756.20.500.20.1.1242 | ColumnnidMSTI11Port2PathCostLocal | read-write | current | NID Series card MSTI Port Configuration: MSTI11 Normal Port2 Configuration - Path Cost Valid values are in the range 0 to 200000000. Setting 0 means Auto path … |
| 1.3.6.1.4.1.4756.20.500.20.1.1243 | ColumnnidMSTI11Port2PriorityLocal | read-write | current | NID Series card MSTI Port Configuration: MSTI8 Normal Port2 Configuration - Priority |
| 1.3.6.1.4.1.4756.20.500.20.1.1244 | ColumnnidMSTI11Port3PathCostLocal | read-write | current | NID Series card MSTI Port Configuration: MSTI8 Normal Port3 Configuration - Path Cost Valid values are in the range 0 to 200000000. Setting 0 means Auto path c… |
| 1.3.6.1.4.1.4756.20.500.20.1.1245 | ColumnnidMSTI11Port3PriorityLocal | read-write | current | NID Series card MSTI Port Configuration: MSTI11 Normal Port3 Configuration - Priority |
| 1.3.6.1.4.1.4756.20.500.20.1.1246 | ColumnnidMSTI11Port4PathCostLocal | read-write | current | NID Series card MSTI Port Configuration: MSTI11 Normal Port4 Configuration - Path Cost Valid values are in the range 0 to 200000000. Setting 0 means Auto path … |
| 1.3.6.1.4.1.4756.20.500.20.1.1247 | ColumnnidMSTI11Port4PriorityLocal | read-write | current | NID Series card MSTI Port Configuration: MSTI11 Normal Port4 Configuration - Priority |
| 1.3.6.1.4.1.4756.20.500.20.1.1248 | ColumnnidMSTI11Port5PathCostLocal | read-write | current | NID Series card MSTI Port Configuration: MSTI11 Normal Port5 Configuration - Path Cost Valid values are in the range 0 to 200000000. Setting 0 means Auto path … |
| 1.3.6.1.4.1.4756.20.500.20.1.1249 | ColumnnidMSTI11Port5PriorityLocal | read-write | current | NID Series card MSTI Port Configuration: MSTI11 Normal Port5 Configuration - Priority |
| 1.3.6.1.4.1.4756.20.500.20.1.1250 | ColumnnidMSTI11Port6PathCostLocal | read-write | current | NID Series card MSTI Port Configuration: MSTI11 Normal Port6 Configuration - Path Cost Valid values are in the range 0 to 200000000. Setting 0 means Auto path … |
| 1.3.6.1.4.1.4756.20.500.20.1.1251 | ColumnnidMSTI11Port6PriorityLocal | read-write | current | NID Series card MSTI Port Configuration: MSTI11 Normal Port6 Configuration - Priority |
| 1.3.6.1.4.1.4756.20.500.20.1.1252 | ColumnnidMSTI11Port7PathCostLocal | read-write | current | NID Series card MSTI Port Configuration: MSTI11 Normal Port7 Configuration - Path Cost Valid values are in the range 0 to 200000000. Setting 0 means Auto path … |
| 1.3.6.1.4.1.4756.20.500.20.1.1253 | ColumnnidMSTI11Port7PriorityLocal | read-write | current | NID Series card MSTI Port Configuration: MSTI11 Normal Port7 Configuration - Priority |
| 1.3.6.1.4.1.4756.20.500.20.1.1254 | ColumnnidMSTI11Port8PathCostLocal | read-write | current | NID Series card MSTI Port Configuration: MSTI8 Normal Port8 Configuration - Path Cost Valid values are in the range 0 to 200000000. Setting 0 means Auto path c… |
| 1.3.6.1.4.1.4756.20.500.20.1.1255 | ColumnnidMSTI11Port8PriorityLocal | read-write | current | NID Series card MSTI Port Configuration: MSTI11 Normal Port8 Configuration - Priority |
| 1.3.6.1.4.1.4756.20.500.20.1.1256 | ColumnnidMSTI12AggregatedPathCostLocal | read-write | current | NID Series card MSTI Port Configuration: MSTI12 Aggregated Ports Configuration - Path Cost Valid values are in the range 0 to 200000000. Setting 0 means Auto p… |
| 1.3.6.1.4.1.4756.20.500.20.1.1257 | ColumnnidMSTI12AggregatedPriorityLocal | read-write | current | NID Series card MSTI Port Configuration: MSTI12 Aggregated Ports Configuration - Priority |
| 1.3.6.1.4.1.4756.20.500.20.1.1258 | ColumnnidMSTI12Port1PathCostLocal | read-write | current | NID Series card MSTI Port Configuration: MSTI12 Normal Port1 Configuration - Path Cost Valid values are in the range 0 to 200000000. Setting 0 means Auto path … |
| 1.3.6.1.4.1.4756.20.500.20.1.1259 | ColumnnidMSTI12Port1PriorityLocal | read-write | current | NID Series card MSTI Port Configuration: MSTI12 Normal Port1 Configuration - Priority |
| 1.3.6.1.4.1.4756.20.500.20.1.1260 | ColumnnidMSTI12Port2PathCostLocal | read-write | current | NID Series card MSTI Port Configuration: MSTI12 Normal Port2 Configuration - Path Cost Valid values are in the range 0 to 200000000. Setting 0 means Auto path … |
| 1.3.6.1.4.1.4756.20.500.20.1.1261 | ColumnnidMSTI12Port2PriorityLocal | read-write | current | NID Series card MSTI Port Configuration: MSTI8 Normal Port2 Configuration - Priority |
| 1.3.6.1.4.1.4756.20.500.20.1.1262 | ColumnnidMSTI12Port3PathCostLocal | read-write | current | NID Series card MSTI Port Configuration: MSTI8 Normal Port3 Configuration - Path Cost Valid values are in the range 0 to 200000000. Setting 0 means Auto path c… |
| 1.3.6.1.4.1.4756.20.500.20.1.1263 | ColumnnidMSTI12Port3PriorityLocal | read-write | current | NID Series card MSTI Port Configuration: MSTI12 Normal Port3 Configuration - Priority |
| 1.3.6.1.4.1.4756.20.500.20.1.1264 | ColumnnidMSTI12Port4PathCostLocal | read-write | current | NID Series card MSTI Port Configuration: MSTI12 Normal Port4 Configuration - Path Cost Valid values are in the range 0 to 200000000. Setting 0 means Auto path … |
| 1.3.6.1.4.1.4756.20.500.20.1.1265 | ColumnnidMSTI12Port4PriorityLocal | read-write | current | NID Series card MSTI Port Configuration: MSTI12 Normal Port4 Configuration - Priority |
| 1.3.6.1.4.1.4756.20.500.20.1.1266 | ColumnnidMSTI12Port5PathCostLocal | read-write | current | NID Series card MSTI Port Configuration: MSTI12 Normal Port5 Configuration - Path Cost Valid values are in the range 0 to 200000000. Setting 0 means Auto path … |
| 1.3.6.1.4.1.4756.20.500.20.1.1267 | ColumnnidMSTI12Port5PriorityLocal | read-write | current | NID Series card MSTI Port Configuration: MSTI12 Normal Port5 Configuration - Priority |
| 1.3.6.1.4.1.4756.20.500.20.1.1268 | ColumnnidMSTI12Port6PathCostLocal | read-write | current | NID Series card MSTI Port Configuration: MSTI12 Normal Port6 Configuration - Path Cost Valid values are in the range 0 to 200000000. Setting 0 means Auto path … |
| 1.3.6.1.4.1.4756.20.500.20.1.1269 | ColumnnidMSTI12Port6PriorityLocal | read-write | current | NID Series card MSTI Port Configuration: MSTI12 Normal Port6 Configuration - Priority |
| 1.3.6.1.4.1.4756.20.500.20.1.1270 | ColumnnidMSTI12Port7PathCostLocal | read-write | current | NID Series card MSTI Port Configuration: MSTI12 Normal Port7 Configuration - Path Cost Valid values are in the range 0 to 200000000. Setting 0 means Auto path … |
| 1.3.6.1.4.1.4756.20.500.20.1.1271 | ColumnnidMSTI12Port7PriorityLocal | read-write | current | NID Series card MSTI Port Configuration: MSTI12 Normal Port7 Configuration - Priority |
| 1.3.6.1.4.1.4756.20.500.20.1.1272 | ColumnnidMSTI12Port8PathCostLocal | read-write | current | NID Series card MSTI Port Configuration: MSTI8 Normal Port8 Configuration - Path Cost Valid values are in the range 0 to 200000000. Setting 0 means Auto path c… |
| 1.3.6.1.4.1.4756.20.500.20.1.1273 | ColumnnidMSTI12Port8PriorityLocal | read-write | current | NID Series card MSTI Port Configuration: MSTI12 Normal Port8 Configuration - Priority |
| 1.3.6.1.4.1.4756.20.500.20.1.1274 | ColumnnidMSTI13AggregatedPathCostLocal | read-write | current | NID Series card MSTI Port Configuration: MSTI13 Aggregated Ports Configuration - Path Cost Valid values are in the range 0 to 200000000. Setting 0 means Auto p… |
| 1.3.6.1.4.1.4756.20.500.20.1.1275 | ColumnnidMSTI13AggregatedPriorityLocal | read-write | current | NID Series card MSTI Port Configuration: MSTI13 Aggregated Ports Configuration - Priority |
| 1.3.6.1.4.1.4756.20.500.20.1.1276 | ColumnnidMSTI13Port1PathCostLocal | read-write | current | NID Series card MSTI Port Configuration: MSTI13 Normal Port1 Configuration - Path Cost Valid values are in the range 0 to 200000000. Setting 0 means Auto path … |
| 1.3.6.1.4.1.4756.20.500.20.1.1277 | ColumnnidMSTI13Port1PriorityLocal | read-write | current | NID Series card MSTI Port Configuration: MSTI13 Normal Port1 Configuration - Priority |
| 1.3.6.1.4.1.4756.20.500.20.1.1278 | ColumnnidMSTI13Port2PathCostLocal | read-write | current | NID Series card MSTI Port Configuration: MSTI13 Normal Port2 Configuration - Path Cost Valid values are in the range 0 to 200000000. Setting 0 means Auto path … |
| 1.3.6.1.4.1.4756.20.500.20.1.1279 | ColumnnidMSTI13Port2PriorityLocal | read-write | current | NID Series card MSTI Port Configuration: MSTI8 Normal Port2 Configuration - Priority |
| 1.3.6.1.4.1.4756.20.500.20.1.1280 | ColumnnidMSTI13Port3PathCostLocal | read-write | current | NID Series card MSTI Port Configuration: MSTI8 Normal Port3 Configuration - Path Cost Valid values are in the range 0 to 200000000. Setting 0 means Auto path c… |
| 1.3.6.1.4.1.4756.20.500.20.1.1281 | ColumnnidMSTI13Port3PriorityLocal | read-write | current | NID Series card MSTI Port Configuration: MSTI13 Normal Port3 Configuration - Priority |
| 1.3.6.1.4.1.4756.20.500.20.1.1282 | ColumnnidMSTI13Port4PathCostLocal | read-write | current | NID Series card MSTI Port Configuration: MSTI13 Normal Port4 Configuration - Path Cost Valid values are in the range 0 to 200000000. Setting 0 means Auto path … |
| 1.3.6.1.4.1.4756.20.500.20.1.1283 | ColumnnidMSTI13Port4PriorityLocal | read-write | current | NID Series card MSTI Port Configuration: MSTI13 Normal Port4 Configuration - Priority |
| 1.3.6.1.4.1.4756.20.500.20.1.1284 | ColumnnidMSTI13Port5PathCostLocal | read-write | current | NID Series card MSTI Port Configuration: MSTI13 Normal Port5 Configuration - Path Cost Valid values are in the range 0 to 200000000. Setting 0 means Auto path … |
| 1.3.6.1.4.1.4756.20.500.20.1.1285 | ColumnnidMSTI13Port5PriorityLocal | read-write | current | NID Series card MSTI Port Configuration: MSTI13 Normal Port5 Configuration - Priority |
| 1.3.6.1.4.1.4756.20.500.20.1.1286 | ColumnnidMSTI13Port6PathCostLocal | read-write | current | NID Series card MSTI Port Configuration: MSTI13 Normal Port6 Configuration - Path Cost Valid values are in the range 0 to 200000000. Setting 0 means Auto path … |
| 1.3.6.1.4.1.4756.20.500.20.1.1287 | ColumnnidMSTI13Port6PriorityLocal | read-write | current | NID Series card MSTI Port Configuration: MSTI13 Normal Port6 Configuration - Priority |
| 1.3.6.1.4.1.4756.20.500.20.1.1288 | ColumnnidMSTI13Port7PathCostLocal | read-write | current | NID Series card MSTI Port Configuration: MSTI13 Normal Port7 Configuration - Path Cost Valid values are in the range 0 to 200000000. Setting 0 means Auto path … |
| 1.3.6.1.4.1.4756.20.500.20.1.1289 | ColumnnidMSTI13Port7PriorityLocal | read-write | current | NID Series card MSTI Port Configuration: MSTI13 Normal Port7 Configuration - Priority |
| 1.3.6.1.4.1.4756.20.500.20.1.1290 | ColumnnidMSTI13Port8PathCostLocal | read-write | current | NID Series card MSTI Port Configuration: MSTI8 Normal Port8 Configuration - Path Cost Valid values are in the range 0 to 200000000. Setting 0 means Auto path c… |
| 1.3.6.1.4.1.4756.20.500.20.1.1291 | ColumnnidMSTI13Port8PriorityLocal | read-write | current | NID Series card MSTI Port Configuration: MSTI13 Normal Port8 Configuration - Priority |
| 1.3.6.1.4.1.4756.20.500.20.1.1292 | ColumnnidMSTI14AggregatedPathCostLocal | read-write | current | NID Series card MSTI Port Configuration: MSTI14 Aggregated Ports Configuration - Path Cost Valid values are in the range 0 to 200000000. Setting 0 means Auto p… |
| 1.3.6.1.4.1.4756.20.500.20.1.1293 | ColumnnidMSTI14AggregatedPriorityLocal | read-write | current | NID Series card MSTI Port Configuration: MSTI14 Aggregated Ports Configuration - Priority |
| 1.3.6.1.4.1.4756.20.500.20.1.1294 | ColumnnidMSTI14Port1PathCostLocal | read-write | current | NID Series card MSTI Port Configuration: MSTI14 Normal Port1 Configuration - Path Cost Valid values are in the range 0 to 200000000. Setting 0 means Auto path … |
| 1.3.6.1.4.1.4756.20.500.20.1.1295 | ColumnnidMSTI14Port1PriorityLocal | read-write | current | NID Series card MSTI Port Configuration: MSTI14 Normal Port1 Configuration - Priority |
| 1.3.6.1.4.1.4756.20.500.20.1.1296 | ColumnnidMSTI14Port2PathCostLocal | read-write | current | NID Series card MSTI Port Configuration: MSTI14 Normal Port2 Configuration - Path Cost Valid values are in the range 0 to 200000000. Setting 0 means Auto path … |
| 1.3.6.1.4.1.4756.20.500.20.1.1297 | ColumnnidMSTI14Port2PriorityLocal | read-write | current | NID Series card MSTI Port Configuration: MSTI8 Normal Port2 Configuration - Priority |
| 1.3.6.1.4.1.4756.20.500.20.1.1298 | ColumnnidMSTI14Port3PathCostLocal | read-write | current | NID Series card MSTI Port Configuration: MSTI8 Normal Port3 Configuration - Path Cost Valid values are in the range 0 to 200000000. Setting 0 means Auto path c… |
| 1.3.6.1.4.1.4756.20.500.20.1.1299 | ColumnnidMSTI14Port3PriorityLocal | read-write | current | NID Series card MSTI Port Configuration: MSTI14 Normal Port3 Configuration - Priority |
| 1.3.6.1.4.1.4756.20.500.20.1.1300 | ColumnnidMSTI14Port4PathCostLocal | read-write | current | NID Series card MSTI Port Configuration: MSTI14 Normal Port4 Configuration - Path Cost Valid values are in the range 0 to 200000000. Setting 0 means Auto path … |
| 1.3.6.1.4.1.4756.20.500.20.1.1301 | ColumnnidMSTI14Port4PriorityLocal | read-write | current | NID Series card MSTI Port Configuration: MSTI14 Normal Port4 Configuration - Priority |
| 1.3.6.1.4.1.4756.20.500.20.1.1302 | ColumnnidMSTI14Port5PathCostLocal | read-write | current | NID Series card MSTI Port Configuration: MSTI14 Normal Port5 Configuration - Path Cost Valid values are in the range 0 to 200000000. Setting 0 means Auto path … |
| 1.3.6.1.4.1.4756.20.500.20.1.1303 | ColumnnidMSTI14Port5PriorityLocal | read-write | current | NID Series card MSTI Port Configuration: MSTI14 Normal Port5 Configuration - Priority |
| 1.3.6.1.4.1.4756.20.500.20.1.1304 | ColumnnidMSTI14Port6PathCostLocal | read-write | current | NID Series card MSTI Port Configuration: MSTI14 Normal Port6 Configuration - Path Cost Valid values are in the range 0 to 200000000. Setting 0 means Auto path … |
| 1.3.6.1.4.1.4756.20.500.20.1.1305 | ColumnnidMSTI14Port6PriorityLocal | read-write | current | NID Series card MSTI Port Configuration: MSTI14 Normal Port6 Configuration - Priority |
| 1.3.6.1.4.1.4756.20.500.20.1.1306 | ColumnnidMSTI14Port7PathCostLocal | read-write | current | NID Series card MSTI Port Configuration: MSTI14 Normal Port7 Configuration - Path Cost Valid values are in the range 0 to 200000000. Setting 0 means Auto path … |
| 1.3.6.1.4.1.4756.20.500.20.1.1307 | ColumnnidMSTI14Port7PriorityLocal | read-write | current | NID Series card MSTI Port Configuration: MSTI14 Normal Port7 Configuration - Priority |
| 1.3.6.1.4.1.4756.20.500.20.1.1308 | ColumnnidMSTI14Port8PathCostLocal | read-write | current | NID Series card MSTI Port Configuration: MSTI8 Normal Port8 Configuration - Path Cost Valid values are in the range 0 to 200000000. Setting 0 means Auto path c… |
| 1.3.6.1.4.1.4756.20.500.20.1.1309 | ColumnnidMSTI14Port8PriorityLocal | read-write | current | NID Series card MSTI Port Configuration: MSTI14 Normal Port8 Configuration - Priority |
| 1.3.6.1.4.1.4756.20.500.20.1.1310 | ColumnnidMSTI15AggregatedPathCostLocal | read-write | current | NID Series card MSTI Port Configuration: MSTI15 Aggregated Ports Configuration - Path Cost Valid values are in the range 0 to 200000000. Setting 0 means Auto p… |
| 1.3.6.1.4.1.4756.20.500.20.1.1311 | ColumnnidMSTI15AggregatedPriorityLocal | read-write | current | NID Series card MSTI Port Configuration: MSTI15 Aggregated Ports Configuration - Priority |
| 1.3.6.1.4.1.4756.20.500.20.1.1312 | ColumnnidMSTI15Port1PathCostLocal | read-write | current | NID Series card MSTI Port Configuration: MSTI15 Normal Port1 Configuration - Path Cost Valid values are in the range 0 to 200000000. Setting 0 means Auto path … |
| 1.3.6.1.4.1.4756.20.500.20.1.1313 | ColumnnidMSTI15Port1PriorityLocal | read-write | current | NID Series card MSTI Port Configuration: MSTI15 Normal Port1 Configuration - Priority |
| 1.3.6.1.4.1.4756.20.500.20.1.1314 | ColumnnidMSTI15Port2PathCostLocal | read-write | current | NID Series card MSTI Port Configuration: MSTI15 Normal Port2 Configuration - Path Cost Valid values are in the range 0 to 200000000. Setting 0 means Auto path … |
| 1.3.6.1.4.1.4756.20.500.20.1.1315 | ColumnnidMSTI15Port2PriorityLocal | read-write | current | NID Series card MSTI Port Configuration: MSTI8 Normal Port2 Configuration - Priority |
| 1.3.6.1.4.1.4756.20.500.20.1.1316 | ColumnnidMSTI15Port3PathCostLocal | read-write | current | NID Series card MSTI Port Configuration: MSTI8 Normal Port3 Configuration - Path Cost Valid values are in the range 0 to 200000000. Setting 0 means Auto path c… |
| 1.3.6.1.4.1.4756.20.500.20.1.1317 | ColumnnidMSTI15Port3PriorityLocal | read-write | current | NID Series card MSTI Port Configuration: MSTI15 Normal Port3 Configuration - Priority |
| 1.3.6.1.4.1.4756.20.500.20.1.1318 | ColumnnidMSTI15Port4PathCostLocal | read-write | current | NID Series card MSTI Port Configuration: MSTI15 Normal Port4 Configuration - Path Cost Valid values are in the range 0 to 200000000. Setting 0 means Auto path … |
| 1.3.6.1.4.1.4756.20.500.20.1.1319 | ColumnnidMSTI15Port4PriorityLocal | read-write | current | NID Series card MSTI Port Configuration: MSTI15 Normal Port4 Configuration - Priority |
| 1.3.6.1.4.1.4756.20.500.20.1.1320 | ColumnnidMSTI15Port5PathCostLocal | read-write | current | NID Series card MSTI Port Configuration: MSTI15 Normal Port5 Configuration - Path Cost Valid values are in the range 0 to 200000000. Setting 0 means Auto path … |
| 1.3.6.1.4.1.4756.20.500.20.1.1321 | ColumnnidMSTI15Port5PriorityLocal | read-write | current | NID Series card MSTI Port Configuration: MSTI15 Normal Port5 Configuration - Priority |
| 1.3.6.1.4.1.4756.20.500.20.1.1322 | ColumnnidMSTI15Port6PathCostLocal | read-write | current | NID Series card MSTI Port Configuration: MSTI15 Normal Port6 Configuration - Path Cost Valid values are in the range 0 to 200000000. Setting 0 means Auto path … |
| 1.3.6.1.4.1.4756.20.500.20.1.1323 | ColumnnidMSTI15Port6PriorityLocal | read-write | current | NID Series card MSTI Port Configuration: MSTI15 Normal Port6 Configuration - Priority |
| 1.3.6.1.4.1.4756.20.500.20.1.1324 | ColumnnidMSTI15Port7PathCostLocal | read-write | current | NID Series card MSTI Port Configuration: MSTI15 Normal Port7 Configuration - Path Cost Valid values are in the range 0 to 200000000. Setting 0 means Auto path … |
| 1.3.6.1.4.1.4756.20.500.20.1.1325 | ColumnnidMSTI15Port7PriorityLocal | read-write | current | NID Series card MSTI Port Configuration: MSTI15 Normal Port7 Configuration - Priority |
| 1.3.6.1.4.1.4756.20.500.20.1.1326 | ColumnnidMSTI15Port8PathCostLocal | read-write | current | NID Series card MSTI Port Configuration: MSTI8 Normal Port8 Configuration - Path Cost Valid values are in the range 0 to 200000000. Setting 0 means Auto path c… |
| 1.3.6.1.4.1.4756.20.500.20.1.1327 | ColumnnidMSTI15Port8PriorityLocal | read-write | current | NID Series card MSTI Port Configuration: MSTI15 Normal Port8 Configuration - Priority |
| 1.3.6.1.4.1.4756.20.500.20.1.1328 | ColumnnidCISTBridgeIDLocal | read-only | current | NID Series card STP Bridges status: CIST - Bridge ID |
| 1.3.6.1.4.1.4756.20.500.20.1.1329 | ColumnnidCISTRootIDLocal | read-only | current | NID Series card STP Bridges status: CIST - Root ID |
| 1.3.6.1.4.1.4756.20.500.20.1.1330 | ColumnnidCISTRootPortLocal | read-only | current | NID Series card STP Bridges status: CIST - Root Port |
| 1.3.6.1.4.1.4756.20.500.20.1.1331 | ColumnnidCISTRootCostLocal | read-only | current | NID Series card STP Bridges status: CIST - Root Cost |
| 1.3.6.1.4.1.4756.20.500.20.1.1332 | ColumnnidCISTTopologyFlagLocal | read-only | current | NID Series card STP Bridges status: CIST - Topology Flag |
| 1.3.6.1.4.1.4756.20.500.20.1.1333 | ColumnnidCISTTopologyChangeLastLocal | read-only | current | NID Series card STP Bridges status: CIST - Topology Change Last |
| 1.3.6.1.4.1.4756.20.500.20.1.1334 | ColumnnidMSTI1BridgeIDLocal | read-only | current | NID Series card STP Bridges status: MSTI1 - Bridge ID |
| 1.3.6.1.4.1.4756.20.500.20.1.1335 | ColumnnidMSTI1RootIDLocal | read-only | current | NID Series card STP Bridges status: MSTI1 - Root ID |
| 1.3.6.1.4.1.4756.20.500.20.1.1336 | ColumnnidMSTI1RootPortLocal | read-only | current | NID Series card STP Bridges status: MSTI1 - Root ID |
| 1.3.6.1.4.1.4756.20.500.20.1.1337 | ColumnnidMSTI1RootCostLocal | read-only | current | NID Series card STP Bridges status: MSTI1 - Root Cost |
| 1.3.6.1.4.1.4756.20.500.20.1.1338 | ColumnnidMSTI1TopologyFlagLocal | read-only | current | NID Series card STP Bridges status: MSTI1 - Topology Flag |
| 1.3.6.1.4.1.4756.20.500.20.1.1339 | ColumnnidMSTI1TopologyChangeLastLocal | read-only | current | NID Series card STP Bridges status: MSTI1 - Topology Change Last |
| 1.3.6.1.4.1.4756.20.500.20.1.1340 | ColumnnidMSTI2BridgeIDLocal | read-only | current | NID Series card STP Bridges status: MSTI2 - Bridge ID |
| 1.3.6.1.4.1.4756.20.500.20.1.1341 | ColumnnidMSTI2RootIDLocal | read-only | current | NID Series card STP Bridges status: MSTI2 - Root ID |
| 1.3.6.1.4.1.4756.20.500.20.1.1342 | ColumnnidMSTI2RootPortLocal | read-only | current | NID Series card STP Bridges status: MSTI2 - Root ID |
| 1.3.6.1.4.1.4756.20.500.20.1.1343 | ColumnnidMSTI2RootCostLocal | read-only | current | NID Series card STP Bridges status: MSTI2 - Root Cost |
| 1.3.6.1.4.1.4756.20.500.20.1.1344 | ColumnnidMSTI2TopologyFlagLocal | read-only | current | NID Series card STP Bridges status: MSTI2 - Topology Flag |
| 1.3.6.1.4.1.4756.20.500.20.1.1345 | ColumnnidMSTI2TopologyChangeLastLocal | read-only | current | NID Series card STP Bridges status: MSTI2 - Topology Change Last |
| 1.3.6.1.4.1.4756.20.500.20.1.1346 | ColumnnidMSTI3BridgeIDLocal | read-only | current | NID Series card STP Bridges status: MSTI3 - Bridge ID |
| 1.3.6.1.4.1.4756.20.500.20.1.1347 | ColumnnidMSTI3RootIDLocal | read-only | current | NID Series card STP Bridges status: MSTI3 - Root ID |
| 1.3.6.1.4.1.4756.20.500.20.1.1348 | ColumnnidMSTI3RootPortLocal | read-only | current | NID Series card STP Bridges status: MSTI3 - Root ID |
| 1.3.6.1.4.1.4756.20.500.20.1.1349 | ColumnnidMSTI3RootCostLocal | read-only | current | NID Series card STP Bridges status: MSTI3 - Root Cost |
| 1.3.6.1.4.1.4756.20.500.20.1.1350 | ColumnnidMSTI3TopologyFlagLocal | read-only | current | NID Series card STP Bridges status: MSTI3 - Topology Flag |
| 1.3.6.1.4.1.4756.20.500.20.1.1351 | ColumnnidMSTI3TopologyChangeLastLocal | read-only | current | NID Series card STP Bridges status: MSTI3 - Topology Change Last |
| 1.3.6.1.4.1.4756.20.500.20.1.1352 | ColumnnidMSTI4BridgeIDLocal | read-only | current | NID Series card STP Bridges status: MSTI4 - Bridge ID |
| 1.3.6.1.4.1.4756.20.500.20.1.1353 | ColumnnidMSTI4RootIDLocal | read-only | current | NID Series card STP Bridges status: MSTI4 - Root ID |
| 1.3.6.1.4.1.4756.20.500.20.1.1354 | ColumnnidMSTI4RootPortLocal | read-only | current | NID Series card STP Bridges status: MSTI4 - Root ID |
| 1.3.6.1.4.1.4756.20.500.20.1.1355 | ColumnnidMSTI4RootCostLocal | read-only | current | NID Series card STP Bridges status: MSTI4 - Root Cost |
| 1.3.6.1.4.1.4756.20.500.20.1.1356 | ColumnnidMSTI4TopologyFlagLocal | read-only | current | NID Series card STP Bridges status: MSTI4 - Topology Flag |
| 1.3.6.1.4.1.4756.20.500.20.1.1357 | ColumnnidMSTI4TopologyChangeLastLocal | read-only | current | NID Series card STP Bridges status: MSTI4 - Topology Change Last |
| 1.3.6.1.4.1.4756.20.500.20.1.1358 | ColumnnidMSTI5BridgeIDLocal | read-only | current | NID Series card STP Bridges status: MSTI5 - Bridge ID |
| 1.3.6.1.4.1.4756.20.500.20.1.1359 | ColumnnidMSTI5RootIDLocal | read-only | current | NID Series card STP Bridges status: MSTI5 - Root ID |
| 1.3.6.1.4.1.4756.20.500.20.1.1360 | ColumnnidMSTI5RootPortLocal | read-only | current | NID Series card STP Bridges status: MSTI5 - Root ID |
| 1.3.6.1.4.1.4756.20.500.20.1.1361 | ColumnnidMSTI5RootCostLocal | read-only | current | NID Series card STP Bridges status: MSTI5 - Root Cost |
| 1.3.6.1.4.1.4756.20.500.20.1.1362 | ColumnnidMSTI5TopologyFlagLocal | read-only | current | NID Series card STP Bridges status: MSTI5 - Topology Flag |
| 1.3.6.1.4.1.4756.20.500.20.1.1363 | ColumnnidMSTI5TopologyChangeLastLocal | read-only | current | NID Series card STP Bridges status: MSTI5 - Topology Change Last |
| 1.3.6.1.4.1.4756.20.500.20.1.1364 | ColumnnidMSTI6BridgeIDLocal | read-only | current | NID Series card STP Bridges status: MSTI6 - Bridge ID |
| 1.3.6.1.4.1.4756.20.500.20.1.1365 | ColumnnidMSTI6RootIDLocal | read-only | current | NID Series card STP Bridges status: MSTI6 - Root ID |
| 1.3.6.1.4.1.4756.20.500.20.1.1366 | ColumnnidMSTI6RootPortLocal | read-only | current | NID Series card STP Bridges status: MSTI6 - Root ID |
| 1.3.6.1.4.1.4756.20.500.20.1.1367 | ColumnnidMSTI6RootCostLocal | read-only | current | NID Series card STP Bridges status: MSTI6 - Root Cost |
| 1.3.6.1.4.1.4756.20.500.20.1.1368 | ColumnnidMSTI6TopologyFlagLocal | read-only | current | NID Series card STP Bridges status: MSTI6 - Topology Flag |
| 1.3.6.1.4.1.4756.20.500.20.1.1369 | ColumnnidMSTI6TopologyChangeLastLocal | read-only | current | NID Series card STP Bridges status: MSTI6 - Topology Change Last |
| 1.3.6.1.4.1.4756.20.500.20.1.1370 | ColumnnidMSTI7BridgeIDLocal | read-only | current | NID Series card STP Bridges status: MSTI7 - Bridge ID |
| 1.3.6.1.4.1.4756.20.500.20.1.1371 | ColumnnidMSTI7RootIDLocal | read-only | current | NID Series card STP Bridges status: MSTI7 - Root ID |
| 1.3.6.1.4.1.4756.20.500.20.1.1372 | ColumnnidMSTI7RootPortLocal | read-only | current | NID Series card STP Bridges status: MSTI7 - Root ID |
| 1.3.6.1.4.1.4756.20.500.20.1.1373 | ColumnnidMSTI7RootCostLocal | read-only | current | NID Series card STP Bridges status: MSTI7 - Root Cost |
| 1.3.6.1.4.1.4756.20.500.20.1.1374 | ColumnnidMSTI7TopologyFlagLocal | read-only | current | NID Series card STP Bridges status: MSTI7 - Topology Flag |
| 1.3.6.1.4.1.4756.20.500.20.1.1375 | ColumnnidMSTI7TopologyChangeLastLocal | read-only | current | NID Series card STP Bridges status: MSTI7 - Topology Change Last |
| 1.3.6.1.4.1.4756.20.500.20.1.1376 | ColumnnidMSTI8BridgeIDLocal | read-only | current | NID Series card STP Bridges status: MSTI8 - Bridge ID |
| 1.3.6.1.4.1.4756.20.500.20.1.1377 | ColumnnidMSTI8RootIDLocal | read-only | current | NID Series card STP Bridges status: MSTI8 - Root ID |
| 1.3.6.1.4.1.4756.20.500.20.1.1378 | ColumnnidMSTI8RootPortLocal | read-only | current | NID Series card STP Bridges status: MSTI8 - Root ID |
| 1.3.6.1.4.1.4756.20.500.20.1.1379 | ColumnnidMSTI8RootCostLocal | read-only | current | NID Series card STP Bridges status: MSTI8 - Root Cost |
| 1.3.6.1.4.1.4756.20.500.20.1.1380 | ColumnnidMSTI8TopologyFlagLocal | read-only | current | NID Series card STP Bridges status: MSTI8 - Topology Flag |
| 1.3.6.1.4.1.4756.20.500.20.1.1381 | ColumnnidMSTI8TopologyChangeLastLocal | read-only | current | NID Series card STP Bridges status: MSTI8 - Topology Change Last |
| 1.3.6.1.4.1.4756.20.500.20.1.1382 | ColumnnidMSTI9BridgeIDLocal | read-only | current | NID Series card STP Bridges status: MSTI9 - Bridge ID |
| 1.3.6.1.4.1.4756.20.500.20.1.1383 | ColumnnidMSTI9RootIDLocal | read-only | current | NID Series card STP Bridges status: MSTI9 - Root ID |
| 1.3.6.1.4.1.4756.20.500.20.1.1384 | ColumnnidMSTI9RootPortLocal | read-only | current | NID Series card STP Bridges status: MSTI9 - Root ID |
| 1.3.6.1.4.1.4756.20.500.20.1.1385 | ColumnnidMSTI9RootCostLocal | read-only | current | NID Series card STP Bridges status: MSTI9 - Root Cost |
| 1.3.6.1.4.1.4756.20.500.20.1.1386 | ColumnnidMSTI9TopologyFlagLocal | read-only | current | NID Series card STP Bridges status: MSTI9 - Topology Flag |
| 1.3.6.1.4.1.4756.20.500.20.1.1387 | ColumnnidMSTI9TopologyChangeLastLocal | read-only | current | NID Series card STP Bridges status: MSTI9 - Topology Change Last |
| 1.3.6.1.4.1.4756.20.500.20.1.1388 | ColumnnidMSTI10BridgeIDLocal | read-only | current | NID Series card STP Bridges status: MSTI10 - Bridge ID |
| 1.3.6.1.4.1.4756.20.500.20.1.1389 | ColumnnidMSTI10RootIDLocal | read-only | current | NID Series card STP Bridges status: MSTI10 - Root ID |
| 1.3.6.1.4.1.4756.20.500.20.1.1390 | ColumnnidMSTI10RootPortLocal | read-only | current | NID Series card STP Bridges status: MSTI10 - Root ID |
| 1.3.6.1.4.1.4756.20.500.20.1.1391 | ColumnnidMSTI10RootCostLocal | read-only | current | NID Series card STP Bridges status: MSTI10 - Root Cost |
| 1.3.6.1.4.1.4756.20.500.20.1.1392 | ColumnnidMSTI10TopologyFlagLocal | read-only | current | NID Series card STP Bridges status: MSTI10 - Topology Flag |
| 1.3.6.1.4.1.4756.20.500.20.1.1393 | ColumnnidMSTI10TopologyChangeLastLocal | read-only | current | NID Series card STP Bridges status: MSTI10 - Topology Change Last |
| 1.3.6.1.4.1.4756.20.500.20.1.1394 | ColumnnidMSTI11BridgeIDLocal | read-only | current | NID Series card STP Bridges status: MSTI11 - Bridge ID |
| 1.3.6.1.4.1.4756.20.500.20.1.1395 | ColumnnidMSTI11RootIDLocal | read-only | current | NID Series card STP Bridges status: MSTI11 - Root ID |
| 1.3.6.1.4.1.4756.20.500.20.1.1396 | ColumnnidMSTI11RootPortLocal | read-only | current | NID Series card STP Bridges status: MSTI11 - Root ID |
| 1.3.6.1.4.1.4756.20.500.20.1.1397 | ColumnnidMSTI11RootCostLocal | read-only | current | NID Series card STP Bridges status: MSTI11 - Root Cost |
| 1.3.6.1.4.1.4756.20.500.20.1.1398 | ColumnnidMSTI11TopologyFlagLocal | read-only | current | NID Series card STP Bridges status: MSTI11 - Topology Flag |
| 1.3.6.1.4.1.4756.20.500.20.1.1399 | ColumnnidMSTI11TopologyChangeLastLocal | read-only | current | NID Series card STP Bridges status: MSTI11 - Topology Change Last |
| 1.3.6.1.4.1.4756.20.500.20.1.1400 | ColumnnidMSTI12BridgeIDLocal | read-only | current | NID Series card STP Bridges status: MSTI12 - Bridge ID |
| 1.3.6.1.4.1.4756.20.500.20.1.1401 | ColumnnidMSTI12RootIDLocal | read-only | current | NID Series card STP Bridges status: MSTI12 - Root ID |
| 1.3.6.1.4.1.4756.20.500.20.1.1402 | ColumnnidMSTI12RootPortLocal | read-only | current | NID Series card STP Bridges status: MSTI12 - Root ID |
| 1.3.6.1.4.1.4756.20.500.20.1.1403 | ColumnnidMSTI12RootCostLocal | read-only | current | NID Series card STP Bridges status: MSTI12 - Root Cost |
| 1.3.6.1.4.1.4756.20.500.20.1.1404 | ColumnnidMSTI12TopologyFlagLocal | read-only | current | NID Series card STP Bridges status: MSTI12 - Topology Flag |
| 1.3.6.1.4.1.4756.20.500.20.1.1405 | ColumnnidMSTI12TopologyChangeLastLocal | read-only | current | NID Series card STP Bridges status: MSTI12 - Topology Change Last |
| 1.3.6.1.4.1.4756.20.500.20.1.1406 | ColumnnidMSTI13BridgeIDLocal | read-only | current | NID Series card STP Bridges status: MSTI13 - Bridge ID |
| 1.3.6.1.4.1.4756.20.500.20.1.1407 | ColumnnidMSTI13RootIDLocal | read-only | current | NID Series card STP Bridges status: MSTI13 - Root ID |
| 1.3.6.1.4.1.4756.20.500.20.1.1408 | ColumnnidMSTI13RootPortLocal | read-only | current | NID Series card STP Bridges status: MSTI13 - Root ID |
| 1.3.6.1.4.1.4756.20.500.20.1.1409 | ColumnnidMSTI13RootCostLocal | read-only | current | NID Series card STP Bridges status: MSTI13 - Root Cost |
| 1.3.6.1.4.1.4756.20.500.20.1.1410 | ColumnnidMSTI13TopologyFlagLocal | read-only | current | NID Series card STP Bridges status: MSTI13 - Topology Flag |
| 1.3.6.1.4.1.4756.20.500.20.1.1411 | ColumnnidMSTI13TopologyChangeLastLocal | read-only | current | NID Series card STP Bridges status: MSTI13 - Topology Change Last |
| 1.3.6.1.4.1.4756.20.500.20.1.1412 | ColumnnidMSTI14BridgeIDLocal | read-only | current | NID Series card STP Bridges status: MSTI14 - Bridge ID |
| 1.3.6.1.4.1.4756.20.500.20.1.1413 | ColumnnidMSTI14RootIDLocal | read-only | current | NID Series card STP Bridges status: MSTI14 - Root ID |
| 1.3.6.1.4.1.4756.20.500.20.1.1414 | ColumnnidMSTI14RootPortLocal | read-only | current | NID Series card STP Bridges status: MSTI14 - Root ID |
| 1.3.6.1.4.1.4756.20.500.20.1.1415 | ColumnnidMSTI14RootCostLocal | read-only | current | NID Series card STP Bridges status: MSTI14 - Root Cost |
| 1.3.6.1.4.1.4756.20.500.20.1.1416 | ColumnnidMSTI14TopologyFlagLocal | read-only | current | NID Series card STP Bridges status: MSTI14 - Topology Flag |
| 1.3.6.1.4.1.4756.20.500.20.1.1417 | ColumnnidMSTI14TopologyChangeLastLocal | read-only | current | NID Series card STP Bridges status: MSTI14 - Topology Change Last |
| 1.3.6.1.4.1.4756.20.500.20.1.1418 | ColumnnidMSTI15BridgeIDLocal | read-only | current | NID Series card STP Bridges status: MSTI15 - Bridge ID |
| 1.3.6.1.4.1.4756.20.500.20.1.1419 | ColumnnidMSTI15RootIDLocal | read-only | current | NID Series card STP Bridges status: MSTI15 - Root ID |
| 1.3.6.1.4.1.4756.20.500.20.1.1420 | ColumnnidMSTI15RootPortLocal | read-only | current | NID Series card STP Bridges status: MSTI15 - Root ID |
| 1.3.6.1.4.1.4756.20.500.20.1.1421 | ColumnnidMSTI15RootCostLocal | read-only | current | NID Series card STP Bridges status: MSTI15 - Root Cost |
| 1.3.6.1.4.1.4756.20.500.20.1.1422 | ColumnnidMSTI15TopologyFlagLocal | read-only | current | NID Series card STP Bridges status: MSTI15 - Topology Flag |
| 1.3.6.1.4.1.4756.20.500.20.1.1423 | ColumnnidMSTI15TopologyChangeLastLocal | read-only | current | NID Series card STP Bridges status: MSTI15 - Topology Change Last |
| 1.3.6.1.4.1.4756.20.500.20.1.1424 | ColumnnidSTPPortStatusInst1PortLocal | read-only | current | NID Series card STP Port status: Instance1 - Port |
| 1.3.6.1.4.1.4756.20.500.20.1.1425 | ColumnnidSTPPortStatusInst1CISTRoleLocal | read-only | current | NID Series card STP Port status: Instance1 - CIST Role |
| 1.3.6.1.4.1.4756.20.500.20.1.1426 | ColumnnidSTPPortStatusInst1CISTStateLocal | read-only | current | NID Series card STP Port status: Instance1 - CIST State |
| 1.3.6.1.4.1.4756.20.500.20.1.1427 | ColumnnidSTPPortStatusInst1UptimeLocal | read-only | current | NID Series card STP Port status: Instance1 -Uptime |
| 1.3.6.1.4.1.4756.20.500.20.1.1428 | ColumnnidSTPPortStatusInst2PortLocal | read-only | current | NID Series card STP Port status: Instance2 - Port |
| 1.3.6.1.4.1.4756.20.500.20.1.1429 | ColumnnidSTPPortStatusInst2CISTRoleLocal | read-only | current | NID Series card STP Port status: Instance2 - CIST Role |
| 1.3.6.1.4.1.4756.20.500.20.1.1430 | ColumnnidSTPPortStatusInst2CISTStateLocal | read-only | current | NID Series card STP Port status: Instance2 - CIST State |
| 1.3.6.1.4.1.4756.20.500.20.1.1431 | ColumnnidSTPPortStatusInst2UptimeLocal | read-only | current | NID Series card STP Port status: Instance2 -Uptime |
| 1.3.6.1.4.1.4756.20.500.20.1.1432 | ColumnnidSTPPortStatusInst3PortLocal | read-only | current | NID Series card STP Port status: Instance3 - Port |
| 1.3.6.1.4.1.4756.20.500.20.1.1433 | ColumnnidSTPPortStatusInst3CISTRoleLocal | read-only | current | NID Series card STP Port status: Instance3 - CIST Role |
| 1.3.6.1.4.1.4756.20.500.20.1.1434 | ColumnnidSTPPortStatusInst3CISTStateLocal | read-only | current | NID Series card STP Port status: Instance3 - CIST State |
| 1.3.6.1.4.1.4756.20.500.20.1.1435 | ColumnnidSTPPortStatusInst3UptimeLocal | read-only | current | NID Series card STP Port status: Instance3 -Uptime |
| 1.3.6.1.4.1.4756.20.500.20.1.1436 | ColumnnidSTPPortStatusInst4PortLocal | read-only | current | NID Series card STP Port status: Instance4 - Port |
| 1.3.6.1.4.1.4756.20.500.20.1.1437 | ColumnnidSTPPortStatusInst4CISTRoleLocal | read-only | current | NID Series card STP Port status: Instance4 - CIST Role |
| 1.3.6.1.4.1.4756.20.500.20.1.1438 | ColumnnidSTPPortStatusInst4CISTStateLocal | read-only | current | NID Series card STP Port status: Instance4 - CIST State |
| 1.3.6.1.4.1.4756.20.500.20.1.1439 | ColumnnidSTPPortStatusInst4UptimeLocal | read-only | current | NID Series card STP Port status: Instance4 -Uptime |
| 1.3.6.1.4.1.4756.20.500.20.1.1440 | ColumnnidSTPPortStatusInst5PortLocal | read-only | current | NID Series card STP Port status: Instance5 - Port |
| 1.3.6.1.4.1.4756.20.500.20.1.1441 | ColumnnidSTPPortStatusInst5CISTRoleLocal | read-only | current | NID Series card STP Port status: Instance5 - CIST Role |
| 1.3.6.1.4.1.4756.20.500.20.1.1442 | ColumnnidSTPPortStatusInst5CISTStateLocal | read-only | current | NID Series card STP Port status: Instance5 - CIST State |
| 1.3.6.1.4.1.4756.20.500.20.1.1443 | ColumnnidSTPPortStatusInst5UptimeLocal | read-only | current | NID Series card STP Port status: Instance5 -Uptime |
| 1.3.6.1.4.1.4756.20.500.20.1.1444 | ColumnnidSTPPortStatusInst6PortLocal | read-only | current | NID Series card STP Port status: Instance6- Port |
| 1.3.6.1.4.1.4756.20.500.20.1.1445 | ColumnnidSTPPortStatusInst6CISTRoleLocal | read-only | current | NID Series card STP Port status: Instance6- CIST Role |
| 1.3.6.1.4.1.4756.20.500.20.1.1446 | ColumnnidSTPPortStatusInst6CISTStateLocal | read-only | current | NID Series card STP Port status: Instance6- CIST State |
| 1.3.6.1.4.1.4756.20.500.20.1.1447 | ColumnnidSTPPortStatusInst6UptimeLocal | read-only | current | NID Series card STP Port status: Instance6-Uptime |
| 1.3.6.1.4.1.4756.20.500.20.1.1448 | ColumnnidSTPPortStatusInst7PortLocal | read-only | current | NID Series card STP Port status: Instance7- Port |
| 1.3.6.1.4.1.4756.20.500.20.1.1449 | ColumnnidSTPPortStatusInst7CISTRoleLocal | read-only | current | NID Series card STP Port status: Instance7- CIST Role |
| 1.3.6.1.4.1.4756.20.500.20.1.1450 | ColumnnidSTPPortStatusInst7CISTStateLocal | read-only | current | NID Series card STP Port status: Instance7- CIST State |
| 1.3.6.1.4.1.4756.20.500.20.1.1451 | ColumnnidSTPPortStatusInst7UptimeLocal | read-only | current | NID Series card STP Port status: Instance7-Uptime |
| 1.3.6.1.4.1.4756.20.500.20.1.1452 | ColumnnidSTPPortStatusInst8PortLocal | read-only | current | NID Series card STP Port status: Instance8- Port |
| 1.3.6.1.4.1.4756.20.500.20.1.1453 | ColumnnidSTPPortStatusInst8CISTRoleLocal | read-only | current | NID Series card STP Port status: Instance8- CIST Role |
| 1.3.6.1.4.1.4756.20.500.20.1.1454 | ColumnnidSTPPortStatusInst8CISTStateLocal | read-only | current | NID Series card STP Port status: Instance8- CIST State |
| 1.3.6.1.4.1.4756.20.500.20.1.1455 | ColumnnidSTPPortStatusInst8UptimeLocal | read-only | current | NID Series card STP Port status: Instance8-Uptime |
| 1.3.6.1.4.1.4756.20.500.20.1.1456 | ColumnnidSTPStatisticsPort1TxMSTPLocal | read-only | current | NID Series card STP Port Statistics: Port1 -Transmitted MSTP |
| 1.3.6.1.4.1.4756.20.500.20.1.1457 | ColumnnidSTPStatisticsPort1TxRSTPLocal | read-only | current | NID Series card STP Port Statistics: Port1 -Transmitted RSTP |
| 1.3.6.1.4.1.4756.20.500.20.1.1458 | ColumnnidSTPStatisticsPort1TxSTPLocal | read-only | current | NID Series card STP Port Statistics: Port1 -Transmitted RSTP |
| 1.3.6.1.4.1.4756.20.500.20.1.1459 | ColumnnidSTPStatisticsPort1TxTCNLocal | read-only | current | NID Series card STP Port Statistics: Port1 -Transmitted RSTP |
| 1.3.6.1.4.1.4756.20.500.20.1.1460 | ColumnnidSTPStatisticsPort1RxMSTPLocal | read-only | current | NID Series card STP Port Statistics: Port1 -Received MSTP |
| 1.3.6.1.4.1.4756.20.500.20.1.1461 | ColumnnidSTPStatisticsPort1RxRSTPLocal | read-only | current | NID Series card STP Port Statistics: Port1 -Received RSTP |
| 1.3.6.1.4.1.4756.20.500.20.1.1462 | ColumnnidSTPStatisticsPort1RxSTPLocal | read-only | current | NID Series card STP Port Statistics: Port1 -Received RSTP |
| 1.3.6.1.4.1.4756.20.500.20.1.1463 | ColumnnidSTPStatisticsPort1RxTCNLocal | read-only | current | NID Series card STP Port Statistics: Port1 -Received RSTP |
| 1.3.6.1.4.1.4756.20.500.20.1.1464 | ColumnnidSTPStatisticsPort1DiscardUnknowLocal | read-only | current | NID Series card STP Port Statistics: Port1 -Discarded Unknown |
| 1.3.6.1.4.1.4756.20.500.20.1.1465 | ColumnnidSTPStatisticsPort1DiscardIllegalLocal | read-only | current | NID Series card STP Port Statistics: Port1 -Discarded Illegal |
| 1.3.6.1.4.1.4756.20.500.20.1.1466 | ColumnnidSTPStatisticsPort2TxMSTPLocal | read-only | current | NID Series card STP Port Statistics: Port2 -Transmitted MSTP |
| 1.3.6.1.4.1.4756.20.500.20.1.1467 | ColumnnidSTPStatisticsPort2TxRSTPLocal | read-only | current | NID Series card STP Port Statistics: Port2 -Transmitted RSTP |
| 1.3.6.1.4.1.4756.20.500.20.1.1468 | ColumnnidSTPStatisticsPort2TxSTPLocal | read-only | current | NID Series card STP Port Statistics: Port2 -Transmitted RSTP |
| 1.3.6.1.4.1.4756.20.500.20.1.1469 | ColumnnidSTPStatisticsPort2TxTCNLocal | read-only | current | NID Series card STP Port Statistics: Port2 -Transmitted RSTP |
| 1.3.6.1.4.1.4756.20.500.20.1.1470 | ColumnnidSTPStatisticsPort2RxMSTPLocal | read-only | current | NID Series card STP Port Statistics: Port2 -Received MSTP |
| 1.3.6.1.4.1.4756.20.500.20.1.1471 | ColumnnidSTPStatisticsPort2RxRSTPLocal | read-only | current | NID Series card STP Port Statistics: Port1 -Received RSTP |
| 1.3.6.1.4.1.4756.20.500.20.1.1472 | ColumnnidSTPStatisticsPort2RxSTPLocal | read-only | current | NID Series card STP Port Statistics: Port2 -Received RSTP |
| 1.3.6.1.4.1.4756.20.500.20.1.1473 | ColumnnidSTPStatisticsPort2RxTCNLocal | read-only | current | NID Series card STP Port Statistics: Port2 -Received RSTP |
| 1.3.6.1.4.1.4756.20.500.20.1.1474 | ColumnnidSTPStatisticsPort2DiscardUnknowLocal | read-only | current | NID Series card STP Port Statistics: Port2 -Discarded Unknown |
| 1.3.6.1.4.1.4756.20.500.20.1.1475 | ColumnnidSTPStatisticsPort2DiscardIllegalLocal | read-only | current | NID Series card STP Port Statistics: Port2 -Discarded Illegal |
| 1.3.6.1.4.1.4756.20.500.20.1.1476 | ColumnnidSTPStatisticsPort3TxMSTPLocal | read-only | current | NID Series card STP Port Statistics: Port3 -Transmitted MSTP |
| 1.3.6.1.4.1.4756.20.500.20.1.1477 | ColumnnidSTPStatisticsPort3TxRSTPLocal | read-only | current | NID Series card STP Port Statistics: Port3 -Transmitted RSTP |
| 1.3.6.1.4.1.4756.20.500.20.1.1478 | ColumnnidSTPStatisticsPort3TxSTPLocal | read-only | current | NID Series card STP Port Statistics: Port3 -Transmitted RSTP |
| 1.3.6.1.4.1.4756.20.500.20.1.1479 | ColumnnidSTPStatisticsPort3TxTCNLocal | read-only | current | NID Series card STP Port Statistics: Port3 -Transmitted RSTP |
| 1.3.6.1.4.1.4756.20.500.20.1.1480 | ColumnnidSTPStatisticsPort3RxMSTPLocal | read-only | current | NID Series card STP Port Statistics: Port3 -Received MSTP |
| 1.3.6.1.4.1.4756.20.500.20.1.1481 | ColumnnidSTPStatisticsPort3RxRSTPLocal | read-only | current | NID Series card STP Port Statistics: Port3 -Received RSTP |
| 1.3.6.1.4.1.4756.20.500.20.1.1482 | ColumnnidSTPStatisticsPort3RxSTPLocal | read-only | current | NID Series card STP Port Statistics: Port3 -Received RSTP |
| 1.3.6.1.4.1.4756.20.500.20.1.1483 | ColumnnidSTPStatisticsPort3RxTCNLocal | read-only | current | NID Series card STP Port Statistics: Port3 -Received RSTP |
| 1.3.6.1.4.1.4756.20.500.20.1.1484 | ColumnnidSTPStatisticsPort3DiscardUnknowLocal | read-only | current | NID Series card STP Port Statistics: Port3 -Discarded Unknown |
| 1.3.6.1.4.1.4756.20.500.20.1.1485 | ColumnnidSTPStatisticsPort3DiscardIllegalLocal | read-only | current | NID Series card STP Port Statistics: Port3 -Discarded Illegal |
| 1.3.6.1.4.1.4756.20.500.20.1.1486 | ColumnnidSTPStatisticsPort4TxMSTPLocal | read-only | current | NID Series card STP Port Statistics: Port4 -Transmitted MSTP |
| 1.3.6.1.4.1.4756.20.500.20.1.1487 | ColumnnidSTPStatisticsPort4TxRSTPLocal | read-only | current | NID Series card STP Port Statistics: Port4 -Transmitted RSTP |
| 1.3.6.1.4.1.4756.20.500.20.1.1488 | ColumnnidSTPStatisticsPort4TxSTPLocal | read-only | current | NID Series card STP Port Statistics: Port4 -Transmitted RSTP |
| 1.3.6.1.4.1.4756.20.500.20.1.1489 | ColumnnidSTPStatisticsPort4TxTCNLocal | read-only | current | NID Series card STP Port Statistics: Port4 -Transmitted RSTP |
| 1.3.6.1.4.1.4756.20.500.20.1.1490 | ColumnnidSTPStatisticsPort4RxMSTPLocal | read-only | current | NID Series card STP Port Statistics: Port4 -Received MSTP |
| 1.3.6.1.4.1.4756.20.500.20.1.1491 | ColumnnidSTPStatisticsPort4RxRSTPLocal | read-only | current | NID Series card STP Port Statistics: Port4 -Received RSTP |
| 1.3.6.1.4.1.4756.20.500.20.1.1492 | ColumnnidSTPStatisticsPort4RxSTPLocal | read-only | current | NID Series card STP Port Statistics: Port4 -Received RSTP |
| 1.3.6.1.4.1.4756.20.500.20.1.1493 | ColumnnidSTPStatisticsPort4RxTCNLocal | read-only | current | NID Series card STP Port Statistics: Port4 -Received RSTP |
| 1.3.6.1.4.1.4756.20.500.20.1.1494 | ColumnnidSTPStatisticsPort4DiscardUnknowLocal | read-only | current | NID Series card STP Port Statistics: Port4 -Discarded Unknown |
| 1.3.6.1.4.1.4756.20.500.20.1.1495 | ColumnnidSTPStatisticsPort4DiscardIllegalLocal | read-only | current | NID Series card STP Port Statistics: Port4 -Discarded Illegal |
| 1.3.6.1.4.1.4756.20.500.20.1.1496 | ColumnnidSTPStatisticsPort5TxMSTPLocal | read-only | current | NID Series card STP Port Statistics: Port5 -Transmitted MSTP |
| 1.3.6.1.4.1.4756.20.500.20.1.1497 | ColumnnidSTPStatisticsPort5TxRSTPLocal | read-only | current | NID Series card STP Port Statistics: Port5 -Transmitted RSTP |
| 1.3.6.1.4.1.4756.20.500.20.1.1498 | ColumnnidSTPStatisticsPort5TxSTPLocal | read-only | current | NID Series card STP Port Statistics: Port5 -Transmitted RSTP |
| 1.3.6.1.4.1.4756.20.500.20.1.1499 | ColumnnidSTPStatisticsPort5TxTCNLocal | read-only | current | NID Series card STP Port Statistics: Port5 -Transmitted RSTP |
| 1.3.6.1.4.1.4756.20.500.20.1.1500 | ColumnnidSTPStatisticsPort5RxMSTPLocal | read-only | current | NID Series card STP Port Statistics: Port5 -Received MSTP |
| 1.3.6.1.4.1.4756.20.500.20.1.1501 | ColumnnidSTPStatisticsPort5RxRSTPLocal | read-only | current | NID Series card STP Port Statistics: Port5 -Received RSTP |
| 1.3.6.1.4.1.4756.20.500.20.1.1502 | ColumnnidSTPStatisticsPort5RxSTPLocal | read-only | current | NID Series card STP Port Statistics: Port5 -Received RSTP |
| 1.3.6.1.4.1.4756.20.500.20.1.1503 | ColumnnidSTPStatisticsPort5RxTCNLocal | read-only | current | NID Series card STP Port Statistics: Port5 -Received RSTP |
| 1.3.6.1.4.1.4756.20.500.20.1.1504 | ColumnnidSTPStatisticsPort5DiscardUnknowLocal | read-only | current | NID Series card STP Port Statistics: Port5 -Discarded Unknown |
| 1.3.6.1.4.1.4756.20.500.20.1.1505 | ColumnnidSTPStatisticsPort5DiscardIllegalLocal | read-only | current | NID Series card STP Port Statistics: Port5 -Discarded Illegal |
| 1.3.6.1.4.1.4756.20.500.20.1.1506 | ColumnnidSTPStatisticsPort6TxMSTPLocal | read-only | current | NID Series card STP Port Statistics: Port6 -Transmitted MSTP |
| 1.3.6.1.4.1.4756.20.500.20.1.1507 | ColumnnidSTPStatisticsPort6TxRSTPLocal | read-only | current | NID Series card STP Port Statistics: Port6 -Transmitted RSTP |
| 1.3.6.1.4.1.4756.20.500.20.1.1508 | ColumnnidSTPStatisticsPort6TxSTPLocal | read-only | current | NID Series card STP Port Statistics: Port6 -Transmitted RSTP |
| 1.3.6.1.4.1.4756.20.500.20.1.1509 | ColumnnidSTPStatisticsPort6TxTCNLocal | read-only | current | NID Series card STP Port Statistics: Port6 -Transmitted RSTP |
| 1.3.6.1.4.1.4756.20.500.20.1.1510 | ColumnnidSTPStatisticsPort6RxMSTPLocal | read-only | current | NID Series card STP Port Statistics: Port6 -Received MSTP |
| 1.3.6.1.4.1.4756.20.500.20.1.1511 | ColumnnidSTPStatisticsPort6RxRSTPLocal | read-only | current | NID Series card STP Port Statistics: Port6 -Received RSTP |
| 1.3.6.1.4.1.4756.20.500.20.1.1512 | ColumnnidSTPStatisticsPort6RxSTPLocal | read-only | current | NID Series card STP Port Statistics: Port6 -Received RSTP |
| 1.3.6.1.4.1.4756.20.500.20.1.1513 | ColumnnidSTPStatisticsPort6RxTCNLocal | read-only | current | NID Series card STP Port Statistics: Port6 -Received RSTP |
| 1.3.6.1.4.1.4756.20.500.20.1.1514 | ColumnnidSTPStatisticsPort6DiscardUnknowLocal | read-only | current | NID Series card STP Port Statistics: Port6 -Discarded Unknown |
| 1.3.6.1.4.1.4756.20.500.20.1.1515 | ColumnnidSTPStatisticsPort6DiscardIllegalLocal | read-only | current | NID Series card STP Port Statistics: Port6 -Discarded Illegal |
| 1.3.6.1.4.1.4756.20.500.20.1.1516 | ColumnnidSTPStatisticsPort7TxMSTPLocal | read-only | current | NID Series card STP Port Statistics: Port7 -Transmitted MSTP |
| 1.3.6.1.4.1.4756.20.500.20.1.1517 | ColumnnidSTPStatisticsPort7TxRSTPLocal | read-only | current | NID Series card STP Port Statistics: Port7 -Transmitted RSTP |
| 1.3.6.1.4.1.4756.20.500.20.1.1518 | ColumnnidSTPStatisticsPort7TxSTPLocal | read-only | current | NID Series card STP Port Statistics: Port7 -Transmitted RSTP |
| 1.3.6.1.4.1.4756.20.500.20.1.1519 | ColumnnidSTPStatisticsPort7TxTCNLocal | read-only | current | NID Series card STP Port Statistics: Port7 -Transmitted RSTP |
| 1.3.6.1.4.1.4756.20.500.20.1.1520 | ColumnnidSTPStatisticsPort7RxMSTPLocal | read-only | current | NID Series card STP Port Statistics: Port7 -Received MSTP |
| 1.3.6.1.4.1.4756.20.500.20.1.1521 | ColumnnidSTPStatisticsPort7RxRSTPLocal | read-only | current | NID Series card STP Port Statistics: Port7 -Received RSTP |
| 1.3.6.1.4.1.4756.20.500.20.1.1522 | ColumnnidSTPStatisticsPort7RxSTPLocal | read-only | current | NID Series card STP Port Statistics: Port7 -Received RSTP |
| 1.3.6.1.4.1.4756.20.500.20.1.1523 | ColumnnidSTPStatisticsPort7RxTCNLocal | read-only | current | NID Series card STP Port Statistics: Port7 -Received RSTP |
| 1.3.6.1.4.1.4756.20.500.20.1.1524 | ColumnnidSTPStatisticsPort7DiscardUnknowLocal | read-only | current | NID Series card STP Port Statistics: Port7 -Discarded Unknown |
| 1.3.6.1.4.1.4756.20.500.20.1.1525 | ColumnnidSTPStatisticsPort7DiscardIllegalLocal | read-only | current | NID Series card STP Port Statistics: Port7 -Discarded Illegal |
| 1.3.6.1.4.1.4756.20.500.20.1.1526 | ColumnnidSTPStatisticsPort8TxMSTPLocal | read-only | current | NID Series card STP Port Statistics: Port8 -Transmitted MSTP |
| 1.3.6.1.4.1.4756.20.500.20.1.1527 | ColumnnidSTPStatisticsPort8TxRSTPLocal | read-only | current | NID Series card STP Port Statistics: Port8 -Transmitted RSTP |
| 1.3.6.1.4.1.4756.20.500.20.1.1528 | ColumnnidSTPStatisticsPort8TxSTPLocal | read-only | current | NID Series card STP Port Statistics: Port8 -Transmitted RSTP |
| 1.3.6.1.4.1.4756.20.500.20.1.1529 | ColumnnidSTPStatisticsPort8TxTCNLocal | read-only | current | NID Series card STP Port Statistics: Port8 -Transmitted RSTP |
| 1.3.6.1.4.1.4756.20.500.20.1.1530 | ColumnnidSTPStatisticsPort8RxMSTPLocal | read-only | current | NID Series card STP Port Statistics: Port8 -Received MSTP |
| 1.3.6.1.4.1.4756.20.500.20.1.1531 | ColumnnidSTPStatisticsPort8RxRSTPLocal | read-only | current | NID Series card STP Port Statistics: Port8 -Received RSTP |
| 1.3.6.1.4.1.4756.20.500.20.1.1532 | ColumnnidSTPStatisticsPort8RxSTPLocal | read-only | current | NID Series card STP Port Statistics: Port8 -Received RSTP |
| 1.3.6.1.4.1.4756.20.500.20.1.1533 | ColumnnidSTPStatisticsPort8RxTCNLocal | read-only | current | NID Series card STP Port Statistics: Port8 -Received RSTP |
| 1.3.6.1.4.1.4756.20.500.20.1.1534 | ColumnnidSTPStatisticsPort8DiscardUnknowLocal | read-only | current | NID Series card STP Port Statistics: Port8 -Discarded Unknown |
| 1.3.6.1.4.1.4756.20.500.20.1.1535 | ColumnnidSTPStatisticsPort8DiscardIllegalLocal | read-only | current | NID Series card STP Port Statistics: Port8 -Discarded Illegal |
| 1.3.6.1.4.1.4756.20.500.20.1.1536 | ColumnnidAllowedAccessVLANsLocal | read-write | current | NID Series card Global VLAN Configuration: Allowed Access VLANs By default, only VLAN 1 is enabled. More VLANs may be created by using a list syntax where the … |
| 1.3.6.1.4.1.4756.20.500.20.1.1537 | ColumnnidVlanEthertypeLocal | read-write | current | NID Series card Global VLAN Configuration: Ethertype for Custom S-ports The format of 'Ethernet Type' is restricted to 0x600-0xFFFF |
| 1.3.6.1.4.1.4756.20.500.20.1.1538 | ColumnnidPort1VlanModeLocal | read-write | current | NID Series card Port VLAN Configuration : Port1 - Mode 0: Access 1: Trunk 2: Hybrid |
| 1.3.6.1.4.1.4756.20.500.20.1.1539 | ColumnnidPort1VlanIDLocal | read-write | current | NID Series card Port VLAN Configuration : Port1 - VLAN ID |
| 1.3.6.1.4.1.4756.20.500.20.1.1540 | ColumnnidPort1VlanTypeLocal | read-write | current | NID Series card Port VLAN Configuration : Port1 - VLAN Type 0: Unaware 1: C-port 2: S-port 3: S-custom-port |
| 1.3.6.1.4.1.4756.20.500.20.1.1541 | ColumnnidPort1VlanIngressFilteringLocal | read-write | current | NID Series card Port VLAN Configuration : Port1 - Ingress Filtering 0: Off 1: On |
| 1.3.6.1.4.1.4756.20.500.20.1.1542 | ColumnnidPort1VlanIngressAcceptanceLocal | read-write | current | NID Series card Port VLAN Configuration : Port1 - Ingress Acceptance 0: Tagged and untagged 1: Tagged only 2: Untagged only |
| 1.3.6.1.4.1.4756.20.500.20.1.1543 | ColumnnidPort1VlanEgressTaggingLocal | read-write | current | NID Series card Port VLAN Configuration : Port1 - Egress Tagging 0: Untag port vlan 1: Tag all 2: Untag all |
| 1.3.6.1.4.1.4756.20.500.20.1.1544 | ColumnnidPort1AllowedVLANSLocal | read-write | current | NID Series card Global VLAN Configuration: Port1 - Allowed VLANs By default, only VLAN 1 is enabled. More VLANs may be created by using a list syntax where the… |
| 1.3.6.1.4.1.4756.20.500.20.1.1545 | ColumnnidPort1ForbiddenVLANSLocal | read-write | current | NID Series card Global VLAN Configuration: Port1 - Forbidden VLANs By default, the field is left blank, which means that the port may become a member of all po… |
| 1.3.6.1.4.1.4756.20.500.20.1.1546 | ColumnnidPort2VlanModeLocal | read-write | current | NID Series card Port VLAN Configuration : Port2 - Mode 0: Access 1: Trunk 2: Hybrid |
| 1.3.6.1.4.1.4756.20.500.20.1.1547 | ColumnnidPort2VlanIDLocal | read-write | current | NID Series card Port VLAN Configuration : Port2 - VLAN ID |
| 1.3.6.1.4.1.4756.20.500.20.1.1548 | ColumnnidPort2VlanTypeLocal | read-write | current | NID Series card Port VLAN Configuration : Port2 - VLAN Type 0: Unaware 1: C-port 2: S-port 3: S-custom-port |
| 1.3.6.1.4.1.4756.20.500.20.1.1549 | ColumnnidPort2VlanIngressFilteringLocal | read-write | current | NID Series card Port VLAN Configuration : Port2 - Ingress Filtering 0: Off 1: On |
| 1.3.6.1.4.1.4756.20.500.20.1.1550 | ColumnnidPort2VlanIngressAcceptanceLocal | read-write | current | NID Series card Port VLAN Configuration : Por2 - Ingress Acceptance 0: Tagged and untagged 1: Tagged only 2: Untagged only |
| 1.3.6.1.4.1.4756.20.500.20.1.1551 | ColumnnidPort2VlanEgressTaggingLocal | read-write | current | NID Series card Port VLAN Configuration : Port2 - Egress Tagging 0: Untag port vlan 1: Tag all 2: Untag all |
| 1.3.6.1.4.1.4756.20.500.20.1.1552 | ColumnnidPort2AllowedVLANSLocal | read-write | current | NID Series card Global VLAN Configuration: Port2 - Allowed VLANs By default, only VLAN 1 is enabled. More VLANs may be created by using a list syntax where the… |
| 1.3.6.1.4.1.4756.20.500.20.1.1553 | ColumnnidPort2ForbiddenVLANSLocal | read-write | current | NID Series card Global VLAN Configuration: Port2 - Forbidden VLANs By default, the field is left blank, which means that the port may become a member of all po… |
| 1.3.6.1.4.1.4756.20.500.20.1.1554 | ColumnnidPort3VlanModeLocal | read-write | current | NID Series card Port VLAN Configuration : Port3 - Mode 0: Access 1: Trunk 2: Hybrid |
| 1.3.6.1.4.1.4756.20.500.20.1.1555 | ColumnnidPort3VlanIDLocal | read-write | current | NID Series card Port VLAN Configuration : Port3 - VLAN ID |
| 1.3.6.1.4.1.4756.20.500.20.1.1556 | ColumnnidPort3VlanTypeLocal | read-write | current | NID Series card Port VLAN Configuration : Port3 - VLAN Type 0: Unaware 1: C-port 2: S-port 3: S-custom-port |
| 1.3.6.1.4.1.4756.20.500.20.1.1557 | ColumnnidPort3VlanIngressFilteringLocal | read-write | current | NID Series card Port VLAN Configuration : Port3 - Ingress Filtering 0: Off 1: On |
| 1.3.6.1.4.1.4756.20.500.20.1.1558 | ColumnnidPort3VlanIngressAcceptanceLocal | read-write | current | NID Series card Port VLAN Configuration : Port3 - Ingress Acceptance 0: Tagged and untagged 1: Tagged only 2: Untagged only |
| 1.3.6.1.4.1.4756.20.500.20.1.1559 | ColumnnidPort3VlanEgressTaggingLocal | read-write | current | NID Series card Port VLAN Configuration : Port3 - Egress Tagging 0: Untag port vlan 1: Tag all 2: Untag all |
| 1.3.6.1.4.1.4756.20.500.20.1.1560 | ColumnnidPort3AllowedVLANSLocal | read-write | current | NID Series card Global VLAN Configuration: Port3 - Allowed VLANs By default, only VLAN 1 is enabled. More VLANs may be created by using a list syntax where the… |
| 1.3.6.1.4.1.4756.20.500.20.1.1561 | ColumnnidPort3ForbiddenVLANSLocal | read-write | current | NID Series card Global VLAN Configuration: Port3 - Forbidden VLANs By default, the field is left blank, which means that the port may become a member of all po… |
| 1.3.6.1.4.1.4756.20.500.20.1.1562 | ColumnnidPort4VlanModeLocal | read-write | current | NID Series card Port VLAN Configuration : Port4 - Mode 0: Access 1: Trunk 2: Hybrid |
| 1.3.6.1.4.1.4756.20.500.20.1.1563 | ColumnnidPort4VlanIDLocal | read-write | current | NID Series card Port VLAN Configuration : Port4 - VLAN ID |
| 1.3.6.1.4.1.4756.20.500.20.1.1564 | ColumnnidPort4VlanTypeLocal | read-write | current | NID Series card Port VLAN Configuration : Port4 - VLAN Type 0: Unaware 1: C-port 2: S-port 3: S-custom-port |
| 1.3.6.1.4.1.4756.20.500.20.1.1565 | ColumnnidPort4VlanIngressFilteringLocal | read-write | current | NID Series card Port VLAN Configuration : Port4 - Ingress Filtering 0: Off 1: On |
| 1.3.6.1.4.1.4756.20.500.20.1.1566 | ColumnnidPort4VlanIngressAcceptanceLocal | read-write | current | NID Series card Port VLAN Configuration : Port4 - Ingress Acceptance 0: Tagged and untagged 1: Tagged only 2: Untagged only |
| 1.3.6.1.4.1.4756.20.500.20.1.1567 | ColumnnidPort4VlanEgressTaggingLocal | read-write | current | NID Series card Port VLAN Configuration : Port4 - Egress Tagging 0: Untag port vlan 1: Tag all 2: Untag all |
| 1.3.6.1.4.1.4756.20.500.20.1.1568 | ColumnnidPort4AllowedVLANSLocal | read-write | current | NID Series card Global VLAN Configuration: Port4 - Allowed VLANs By default, only VLAN 1 is enabled. More VLANs may be created by using a list syntax where the… |
| 1.3.6.1.4.1.4756.20.500.20.1.1569 | ColumnnidPort4ForbiddenVLANSLocal | read-write | current | NID Series card Global VLAN Configuration: Port4 - Forbidden VLANs By default, the field is left blank, which means that the port may become a member of all po… |
| 1.3.6.1.4.1.4756.20.500.20.1.1570 | ColumnnidPort5VlanModeLocal | read-write | current | NID Series card Port VLAN Configuration : Port5 - Mode 0: Access 1: Trunk 2: Hybrid |
| 1.3.6.1.4.1.4756.20.500.20.1.1571 | ColumnnidPort5VlanIDLocal | read-write | current | NID Series card Port VLAN Configuration : Port5 - VLAN ID |
| 1.3.6.1.4.1.4756.20.500.20.1.1572 | ColumnnidPort5VlanTypeLocal | read-write | current | NID Series card Port VLAN Configuration : Port5 - VLAN Type 0: Unaware 1: C-port 2: S-port 3: S-custom-port |
| 1.3.6.1.4.1.4756.20.500.20.1.1573 | ColumnnidPort5VlanIngressFilteringLocal | read-write | current | NID Series card Port VLAN Configuration : Port5 - Ingress Filtering 0: Off 1: On |
| 1.3.6.1.4.1.4756.20.500.20.1.1574 | ColumnnidPort5VlanIngressAcceptanceLocal | read-write | current | NID Series card Port VLAN Configuration : Port5 - Ingress Acceptance 0: Tagged and untagged 1: Tagged only 2: Untagged only |
| 1.3.6.1.4.1.4756.20.500.20.1.1575 | ColumnnidPort5VlanEgressTaggingLocal | read-write | current | NID Series card Port VLAN Configuration : Port5 - Egress Tagging 0: Untag port vlan 1: Tag all 2: Untag all |
| 1.3.6.1.4.1.4756.20.500.20.1.1576 | ColumnnidPort5AllowedVLANSLocal | read-write | current | NID Series card Global VLAN Configuration: Port5 - Allowed VLANs By default, only VLAN 1 is enabled. More VLANs may be created by using a list syntax where the… |
| 1.3.6.1.4.1.4756.20.500.20.1.1577 | ColumnnidPort5ForbiddenVLANSLocal | read-write | current | NID Series card Global VLAN Configuration: Port5 - Forbidden VLANs By default, the field is left blank, which means that the port may become a member of all po… |
| 1.3.6.1.4.1.4756.20.500.20.1.1578 | ColumnnidPort6VlanModeLocal | read-write | current | NID Series card Port VLAN Configuration : Port6 - Mode 0: Access 1: Trunk 2: Hybrid |
| 1.3.6.1.4.1.4756.20.500.20.1.1579 | ColumnnidPort6VlanIDLocal | read-write | current | NID Series card Port VLAN Configuration : Port6 - VLAN ID |
| 1.3.6.1.4.1.4756.20.500.20.1.1580 | ColumnnidPort6VlanTypeLocal | read-write | current | NID Series card Port VLAN Configuration : Port6 - VLAN Type 0: Unaware 1: C-port 2: S-port 3: S-custom-port |
| 1.3.6.1.4.1.4756.20.500.20.1.1581 | ColumnnidPort6VlanIngressFilteringLocal | read-write | current | NID Series card Port VLAN Configuration : Port6 - Ingress Filtering 0: Off 1: On |
| 1.3.6.1.4.1.4756.20.500.20.1.1582 | ColumnnidPort6VlanIngressAcceptanceLocal | read-write | current | NID Series card Port VLAN Configuration : Port6 - Ingress Acceptance 0: Tagged and untagged 1: Tagged only 2: Untagged only |
| 1.3.6.1.4.1.4756.20.500.20.1.1583 | ColumnnidPort6VlanEgressTaggingLocal | read-write | current | NID Series card Port VLAN Configuration : Port6 - Egress Tagging 0: Untag port vlan 1: Tag all 2: Untag all |
| 1.3.6.1.4.1.4756.20.500.20.1.1584 | ColumnnidPort6AllowedVLANSLocal | read-write | current | NID Series card Global VLAN Configuration: Port6 - Allowed VLANs By default, only VLAN 1 is enabled. More VLANs may be created by using a list syntax where the… |
| 1.3.6.1.4.1.4756.20.500.20.1.1585 | ColumnnidPort6ForbiddenVLANSLocal | read-write | current | NID Series card Global VLAN Configuration: Port6 - Forbidden VLANs By default, the field is left blank, which means that the port may become a member of all po… |
| 1.3.6.1.4.1.4756.20.500.20.1.1586 | ColumnnidPort7VlanModeLocal | read-write | current | NID Series card Port VLAN Configuration : Port7 - Mode 0: Access 1: Trunk 2: Hybrid |
| 1.3.6.1.4.1.4756.20.500.20.1.1587 | ColumnnidPort7VlanIDLocal | read-write | current | NID Series card Port VLAN Configuration : Port7 - VLAN ID |
| 1.3.6.1.4.1.4756.20.500.20.1.1588 | ColumnnidPort7VlanTypeLocal | read-write | current | NID Series card Port VLAN Configuration : Port7 - VLAN Type 0: Unaware 1: C-port 2: S-port 3: S-custom-port |
| 1.3.6.1.4.1.4756.20.500.20.1.1589 | ColumnnidPort7VlanIngressFilteringLocal | read-write | current | NID Series card Port VLAN Configuration : Port7 - Ingress Filtering 0: Off 1: On |
| 1.3.6.1.4.1.4756.20.500.20.1.1590 | ColumnnidPort7VlanIngressAcceptanceLocal | read-write | current | NID Series card Port VLAN Configuration : Port7 - Ingress Acceptance 0: Tagged and untagged 1: Tagged only 2: Untagged only |
| 1.3.6.1.4.1.4756.20.500.20.1.1591 | ColumnnidPort7VlanEgressTaggingLocal | read-write | current | NID Series card Port VLAN Configuration : Port7 - Egress Tagging 0: Untag port vlan 1: Tag all 2: Untag all |
| 1.3.6.1.4.1.4756.20.500.20.1.1592 | ColumnnidPort7AllowedVLANSLocal | read-write | current | NID Series card Global VLAN Configuration: Port7 - Allowed VLANs By default, only VLAN 1 is enabled. More VLANs may be created by using a list syntax where the… |
| 1.3.6.1.4.1.4756.20.500.20.1.1593 | ColumnnidPort7ForbiddenVLANSLocal | read-write | current | NID Series card Global VLAN Configuration: Port7 - Forbidden VLANs By default, the field is left blank, which means that the port may become a member of all po… |
| 1.3.6.1.4.1.4756.20.500.20.1.1594 | ColumnnidPort8VlanModeLocal | read-write | current | NID Series card Port VLAN Configuration : Port8 - Mode 0: Access 1: Trunk 2: Hybrid |
| 1.3.6.1.4.1.4756.20.500.20.1.1595 | ColumnnidPort8VlanIDLocal | read-write | current | NID Series card Port VLAN Configuration : Port8 - VLAN ID |
| 1.3.6.1.4.1.4756.20.500.20.1.1596 | ColumnnidPort8VlanTypeLocal | read-write | current | NID Series card Port VLAN Configuration : Port8 - VLAN Type 0: Unaware 1: C-port 2: S-port 3: S-custom-port |
| 1.3.6.1.4.1.4756.20.500.20.1.1597 | ColumnnidPort8VlanIngressFilteringLocal | read-write | current | NID Series card Port VLAN Configuration : Port8 - Ingress Filtering 0: Off 1: On |
| 1.3.6.1.4.1.4756.20.500.20.1.1598 | ColumnnidPort8VlanIngressAcceptanceLocal | read-write | current | NID Series card Port VLAN Configuration : Port8 - Ingress Acceptance 0: Tagged and untagged 1: Tagged only 2: Untagged only |
| 1.3.6.1.4.1.4756.20.500.20.1.1599 | ColumnnidPort8VlanEgressTaggingLocal | read-write | current | NID Series card Port VLAN Configuration : Port8 - Egress Tagging 0: Untag port vlan 1: Tag all 2: Untag all |
| 1.3.6.1.4.1.4756.20.500.20.1.1600 | ColumnnidPort8AllowedVLANSLocal | read-write | current | NID Series card Global VLAN Configuration: Port8 - Allowed VLANs By default, only VLAN 1 is enabled. More VLANs may be created by using a list syntax where the… |
| 1.3.6.1.4.1.4756.20.500.20.1.1601 | ColumnnidPort8ForbiddenVLANSLocal | read-write | current | NID Series card Global VLAN Configuration: Port8 - Forbidden VLANs By default, the field is left blank, which means that the port may become a member of all po… |
| 1.3.6.1.4.1.4756.20.500.20.1.1602 | ColumnnidQOSPort1IngressLocal | read-write | current | NID Series card QOS Port1 Ingress Enabled 0: NO 1: YES |
| 1.3.6.1.4.1.4756.20.500.20.1.1603 | ColumnnidQOSPort1IngressRateLocal | read-write | current | NID Series card QOS Port1 Ingress Rate |
| 1.3.6.1.4.1.4756.20.500.20.1.1604 | ColumnnidQOSPort1IngressRateUnitLocal | read-write | current | NID Series card QOS Port1 Ingress Rate Unit 0: Kbps 1: Mbps 2: fps 3: kfps |
| 1.3.6.1.4.1.4756.20.500.20.1.1605 | ColumnnidQOSPort1IngressFlowControlLocal | read-write | current | NID Series card QOS Port1 Ingress Flow Control 0: NO 1: YES |
| 1.3.6.1.4.1.4756.20.500.20.1.1606 | ColumnnidQOSPort2IngressLocal | read-write | current | NID Series card QOS Port2 Ingress Enabled 0: NO 1: YES |
| 1.3.6.1.4.1.4756.20.500.20.1.1607 | ColumnnidQOSPort2IngressRateLocal | read-write | current | NID Series card QOS Port2 Ingress Rate |
| 1.3.6.1.4.1.4756.20.500.20.1.1608 | ColumnnidQOSPort2IngressRateUnitLocal | read-write | current | NID Series card QOS Port2 Ingress Rate Unit 0: Kbps 1: Mbps 2: fps 3: kfps |
| 1.3.6.1.4.1.4756.20.500.20.1.1609 | ColumnnidQOSPort2IngressFlowControlLocal | read-write | current | NID Series card QOS Port2 Ingress Flow Control 0: NO 1: YES |
| 1.3.6.1.4.1.4756.20.500.20.1.1610 | ColumnnidQOSPort3IngressLocal | read-write | current | NID Series card QOS Port3 Ingress Enabled 0: NO 1: YES |
| 1.3.6.1.4.1.4756.20.500.20.1.1611 | ColumnnidQOSPort3IngressRateLocal | read-write | current | NID Series card QOS Port3 Ingress Rate |
| 1.3.6.1.4.1.4756.20.500.20.1.1612 | ColumnnidQOSPort3IngressRateUnitLocal | read-write | current | NID Series card QOS Port3 Ingress Rate Unit 0: Kbps 1: Mbps 2: fps 3: kfps |
| 1.3.6.1.4.1.4756.20.500.20.1.1613 | ColumnnidQOSPort3IngressFlowControlLocal | read-write | current | NID Series card QOS Port3 Ingress Flow Control 0: NO 1: YES |
| 1.3.6.1.4.1.4756.20.500.20.1.1614 | ColumnnidQOSPort4IngressLocal | read-write | current | NID Series card QOS Port4 Ingress Enabled 0: NO 1: YES |
| 1.3.6.1.4.1.4756.20.500.20.1.1615 | ColumnnidQOSPort4IngressRateLocal | read-write | current | NID Series card QOS Port4 Ingress Rate |
| 1.3.6.1.4.1.4756.20.500.20.1.1616 | ColumnnidQOSPort4IngressRateUnitLocal | read-write | current | NID Series card QOS Port4 Ingress Rate Unit 0: Kbps 1: Mbps 2: fps 3: kfps |
| 1.3.6.1.4.1.4756.20.500.20.1.1617 | ColumnnidQOSPort4IngressFlowControlLocal | read-write | current | NID Series card QOS Port4 Ingress Flow Control 0: NO 1: YES |
| 1.3.6.1.4.1.4756.20.500.20.1.1618 | ColumnnidQOSPort5IngressLocal | read-write | current | NID Series card QOS Port5 Ingress Enabled 0: NO 1: YES |
| 1.3.6.1.4.1.4756.20.500.20.1.1619 | ColumnnidQOSPort5IngressRateLocal | read-write | current | NID Series card QOS Port5 Ingress Rate |
| 1.3.6.1.4.1.4756.20.500.20.1.1620 | ColumnnidQOSPort5IngressRateUnitLocal | read-write | current | NID Series card QOS Port5 Ingress Rate Unit 0: Kbps 1: Mbps 2: fps 3: kfps |
| 1.3.6.1.4.1.4756.20.500.20.1.1621 | ColumnnidQOSPort5IngressFlowControlLocal | read-write | current | NID Series card QOS Port5 Ingress Flow Control 0: NO 1: YES |
| 1.3.6.1.4.1.4756.20.500.20.1.1622 | ColumnnidQOSPort6IngressLocal | read-write | current | NID Series card QOS Port6 Ingress Enabled 0: NO 1: YES |
| 1.3.6.1.4.1.4756.20.500.20.1.1623 | ColumnnidQOSPort6IngressRateLocal | read-write | current | NID Series card QOS Port6 Ingress Rate |
| 1.3.6.1.4.1.4756.20.500.20.1.1624 | ColumnnidQOSPort6IngressRateUnitLocal | read-write | current | NID Series card QOS Port6 Ingress Rate Unit 0: Kbps 1: Mbps 2: fps 3: kfps |
| 1.3.6.1.4.1.4756.20.500.20.1.1625 | ColumnnidQOSPort6IngressFlowControlLocal | read-write | current | NID Series card QOS Port6 Ingress Flow Control 0: NO 1: YES |
| 1.3.6.1.4.1.4756.20.500.20.1.1626 | ColumnnidQOSPort7IngressLocal | read-write | current | NID Series card QOS Port7 Ingress Enabled 0: NO 1: YES |
| 1.3.6.1.4.1.4756.20.500.20.1.1627 | ColumnnidQOSPort7IngressRateLocal | read-write | current | NID Series card QOS Port7 Ingress Rate |
| 1.3.6.1.4.1.4756.20.500.20.1.1628 | ColumnnidQOSPort7IngressRateUnitLocal | read-write | current | NID Series card QOS Port7 Ingress Rate Unit 0: Kbps 1: Mbps 2: fps 3: kfps |
| 1.3.6.1.4.1.4756.20.500.20.1.1629 | ColumnnidQOSPort7IngressFlowControlLocal | read-write | current | NID Series card QOS Port7 Ingress Flow Control 0: NO 1: YES |
| 1.3.6.1.4.1.4756.20.500.20.1.1630 | ColumnnidQOSPort8IngressLocal | read-write | current | NID Series card QOS Port8 Ingress Enabled 0: NO 1: YES |
| 1.3.6.1.4.1.4756.20.500.20.1.1631 | ColumnnidQOSPort8IngressRateLocal | read-write | current | NID Series card QOS Port8 Ingress Rate |
| 1.3.6.1.4.1.4756.20.500.20.1.1632 | ColumnnidQOSPort8IngressRateUnitLocal | read-write | current | NID Series card QOS Port8 Ingress Rate Unit 0: Kbps 1: Mbps 2: fps 3: kfps |
| 1.3.6.1.4.1.4756.20.500.20.1.1633 | ColumnnidQOSPort8IngressFlowControlLocal | read-write | current | NID Series card QOS Port8 Ingress Flow Control 0: NO 1: YES |
| 1.3.6.1.4.1.4756.20.500.20.1.1634 | ColumnnidQOSPort1EgressLocal | read-write | current | NID Series card QOS Port1 Egress Enabled 0: NO 1: YES |
| 1.3.6.1.4.1.4756.20.500.20.1.1635 | ColumnnidQOSPort1EgressRateLocal | read-write | current | NID Series card QOS Port1 Egress Rate |
| 1.3.6.1.4.1.4756.20.500.20.1.1636 | ColumnnidQOSPort1EgressRateUnitLocal | read-write | current | NID Series card QOS Port1 Egress Rate Unit 0: Kbps 1: Mbps |
| 1.3.6.1.4.1.4756.20.500.20.1.1637 | ColumnnidQOSPort2EgressLocal | read-write | current | NID Series card QOS Port2 Egress Enabled 0: NO 1: YES |
| 1.3.6.1.4.1.4756.20.500.20.1.1638 | ColumnnidQOSPort2EgressRateLocal | read-write | current | NID Series card QOS Port2 Egress Rate |
| 1.3.6.1.4.1.4756.20.500.20.1.1639 | ColumnnidQOSPort2EgressRateUnitLocal | read-write | current | NID Series card QOS Port2 Egress Rate Unit 0: Kbps 1: Mbps |
| 1.3.6.1.4.1.4756.20.500.20.1.1640 | ColumnnidQOSPort3EgressLocal | read-write | current | NID Series card QOS Port3 Egress Enabled 0: NO 1: YES |
| 1.3.6.1.4.1.4756.20.500.20.1.1641 | ColumnnidQOSPort3EgressRateLocal | read-write | current | NID Series card QOS Port3 Egress Rate |
| 1.3.6.1.4.1.4756.20.500.20.1.1642 | ColumnnidQOSPort3EgressRateUnitLocal | read-write | current | NID Series card QOS Port3 Egress Rate Unit 0: Kbps 1: Mbps |
| 1.3.6.1.4.1.4756.20.500.20.1.1643 | ColumnnidQOSPort4EgressLocal | read-write | current | NID Series card QOS Port4 Egress Enabled 0: NO 1: YES |
| 1.3.6.1.4.1.4756.20.500.20.1.1644 | ColumnnidQOSPort4EgressRateLocal | read-write | current | NID Series card QOS Port4 Egress Rate |
| 1.3.6.1.4.1.4756.20.500.20.1.1645 | ColumnnidQOSPort4EgressRateUnitLocal | read-write | current | NID Series card QOS Port4 Egress Rate Unit 0: Kbps 1: Mbps |
| 1.3.6.1.4.1.4756.20.500.20.1.1646 | ColumnnidQOSPort5EgressLocal | read-write | current | NID Series card QOS Port5 Egress Enabled 0: NO 1: YES |
| 1.3.6.1.4.1.4756.20.500.20.1.1647 | ColumnnidQOSPort5EgressRateLocal | read-write | current | NID Series card QOS Port5 Egress Rate |
| 1.3.6.1.4.1.4756.20.500.20.1.1648 | ColumnnidQOSPort5EgressRateUnitLocal | read-write | current | NID Series card QOS Port5 Egress Rate Unit 0: Kbps 1: Mbps |
| 1.3.6.1.4.1.4756.20.500.20.1.1649 | ColumnnidQOSPort6EgressLocal | read-write | current | NID Series card QOS Port6 Egress Enabled 0: NO 1: YES |
| 1.3.6.1.4.1.4756.20.500.20.1.1650 | ColumnnidQOSPort6EgressRateLocal | read-write | current | NID Series card QOS Port6 Egress Rate |
| 1.3.6.1.4.1.4756.20.500.20.1.1651 | ColumnnidQOSPort6EgressRateUnitLocal | read-write | current | NID Series card QOS Port6 Egress Rate Unit 0: Kbps 1: Mbps |
| 1.3.6.1.4.1.4756.20.500.20.1.1652 | ColumnnidQOSPort7EgressLocal | read-write | current | NID Series card QOS Port7 Egress Enabled 0: NO 1: YES |
| 1.3.6.1.4.1.4756.20.500.20.1.1653 | ColumnnidQOSPort7EgressRateLocal | read-write | current | NID Series card QOS Port7 Egress Rate |
| 1.3.6.1.4.1.4756.20.500.20.1.1654 | ColumnnidQOSPort7EgressRateUnitLocal | read-write | current | NID Series card QOS Port7 Egress Rate Unit 0: Kbps 1: Mbps |
| 1.3.6.1.4.1.4756.20.500.20.1.1655 | ColumnnidQOSPort8EgressLocal | read-write | current | NID Series card QOS Port8 Egress Enabled 0: NO 1: YES |
| 1.3.6.1.4.1.4756.20.500.20.1.1656 | ColumnnidQOSPort8EgressRateLocal | read-write | current | NID Series card QOS Port8 Egress Rate |
| 1.3.6.1.4.1.4756.20.500.20.1.1657 | ColumnnidQOSPort8EgressRateUnitLocal | read-write | current | NID Series card QOS Port8 Egress Rate Unit 0: Kbps 1: Mbps |
| 1.3.6.1.4.1.4756.20.500.20.1.1658 | ColumnnidQOSUnicastLocal | read-write | current | NID Series card QOS Storm Control Configuration- Unicast 0: NO 1: YES |
| 1.3.6.1.4.1.4756.20.500.20.1.1659 | ColumnnidQOSUnicastRateLocal | read-write | current | NID Series card QOS Storm Control Configuration- Unicast Rate The rate unit is packets per second (pps). 0: 1 1: 2 2: 4 3: 8 4: 16 5: 32 6: 64 7: 128 8: 256 9:… |
| 1.3.6.1.4.1.4756.20.500.20.1.1660 | ColumnnidQOSMulticastLocal | read-write | current | NID Series card QOS Storm Control Configuration- Multicast 0: NO 1: YES |
| 1.3.6.1.4.1.4756.20.500.20.1.1661 | ColumnnidQOSMulticastRateLocal | read-write | current | NID Series card QOS Storm Control Configuration- Multicast The rate unit is packets per second (pps). 0: 1 1: 2 2: 4 3: 8 4: 16 5: 32 6: 64 7: 128 8: 256 9: 51… |
| 1.3.6.1.4.1.4756.20.500.20.1.1662 | ColumnnidQOSBroadcastLocal | read-write | current | NID Series card QOS Storm Control Configuration- Broadcast 0: NO 1: YES |
| 1.3.6.1.4.1.4756.20.500.20.1.1663 | ColumnnidQOSBroadcastRateLocal | read-write | current | NID Series card QOS Storm Control Configuration- Broadcast The rate unit is packets per second (pps). 0: 1 1: 2 2: 4 3: 8 4: 16 5: 32 6: 64 7: 128 8: 256 9: 51… |
| 1.3.6.1.4.1.4756.20.500.20.1.1664 | ColumnnidL2CPPort1DMAC0180C2000000Local | read-write | current | NID Series card Port 1 L2CP Mode 0180C2000000 0: Forward 1: Discard 2: Peer |
| 1.3.6.1.4.1.4756.20.500.20.1.1665 | ColumnnidL2CPPort1DMAC0180C2000001Local | read-write | current | NID Series card Port 1 L2CP Mode 0180C2000001 0: Forward 1: Discard 2: Peer |
| 1.3.6.1.4.1.4756.20.500.20.1.1666 | ColumnnidL2CPPort1DMAC0180C2000002Local | read-write | current | NID Series card Port 1 L2CP Mode 0180C2000002 0: Forward 1: Discard 2: Peer |
| 1.3.6.1.4.1.4756.20.500.20.1.1667 | ColumnnidL2CPPort1DMAC0180C2000003Local | read-write | current | NID Series card Port 1 L2CP Mode 0180C2000003 0: Forward 1: Discard 2: Peer |
| 1.3.6.1.4.1.4756.20.500.20.1.1668 | ColumnnidL2CPPort1DMAC0180C2000004Local | read-write | current | NID Series card Port 1 L2CP Mode 0180C2000004 0: Forward 1: Discard 2: Peer |
| 1.3.6.1.4.1.4756.20.500.20.1.1669 | ColumnnidL2CPPort1DMAC0180C2000005Local | read-write | current | NID Series card Port 1 L2CP Mode 0180C2000005 0: Forward 1: Discard 2: Peer |
| 1.3.6.1.4.1.4756.20.500.20.1.1670 | ColumnnidL2CPPort1DMAC0180C2000006Local | read-write | current | NID Series card Port 1 L2CP Mode 0180C2000006 0: Forward 1: Discard 2: Peer |
| 1.3.6.1.4.1.4756.20.500.20.1.1671 | ColumnnidL2CPPort1DMAC0180C2000007Local | read-write | current | NID Series card Port 1 L2CP Mode 0180C2000007 0: Forward 1: Discard 2: Peer |
| 1.3.6.1.4.1.4756.20.500.20.1.1672 | ColumnnidL2CPPort1DMAC0180C2000008Local | read-write | current | NID Series card Port 1 L2CP Mode 0180C2000008 0: Forward 1: Discard 2: Peer |
| 1.3.6.1.4.1.4756.20.500.20.1.1673 | ColumnnidL2CPPort1DMAC0180C2000009Local | read-write | current | NID Series card Port 1 L2CP Mode 0180C2000009 0: Forward 1: Discard 2: Peer |
| 1.3.6.1.4.1.4756.20.500.20.1.1674 | ColumnnidL2CPPort1DMAC0180C200000ALocal | read-write | current | NID Series card Port 1 L2CP Mode 0180C200000A 0: Forward 1: Discard 2: Peer |
| 1.3.6.1.4.1.4756.20.500.20.1.1675 | ColumnnidL2CPPort1DMAC0180C200000BLocal | read-write | current | NID Series card Port 1 L2CP Mode 0180C200000B 0: Forward 1: Discard 2: Peer |
| 1.3.6.1.4.1.4756.20.500.20.1.1676 | ColumnnidL2CPPort1DMAC0180C200000CLocal | read-write | current | NID Series card Port 1 L2CP Mode 0180C200000C 0: Forward 1: Discard 2: Peer |
| 1.3.6.1.4.1.4756.20.500.20.1.1677 | ColumnnidL2CPPort1DMAC0180C200000DLocal | read-write | current | NID Series card Port 1 L2CP Mode 0180C200000D 0: Forward 1: Discard 2: Peer |
| 1.3.6.1.4.1.4756.20.500.20.1.1678 | ColumnnidL2CPPort1DMAC0180C200000ELocal | read-write | current | NID Series card Port 1 L2CP Mode 0180C200000E 0: Forward 1: Discard 2: Peer |
| 1.3.6.1.4.1.4756.20.500.20.1.1679 | ColumnnidL2CPPort1DMAC0180C200000FLocal | read-write | current | NID Series card Port 1 L2CP Mode 0180C200000F 0: Forward 1: Discard 2: Peer |
| 1.3.6.1.4.1.4756.20.500.20.1.1680 | ColumnnidL2CPPort1DMAC0180C2000010Local | read-write | current | NID Series card Port 1 L2CP Mode 0180C2000010 0: Forward 1: Discard 2: Peer |
| 1.3.6.1.4.1.4756.20.500.20.1.1681 | ColumnnidL2CPPort1DMAC0180C2000020Local | read-write | current | NID Series card Port 1 L2CP Mode 0180C2000020 0: Forward 1: Discard 2: Peer |
| 1.3.6.1.4.1.4756.20.500.20.1.1682 | ColumnnidL2CPPort1DMAC0180C2000021Local | read-write | current | NID Series card Port 1 L2CP Mode 0180C2000021 0: Forward 1: Discard 2: Peer |
| 1.3.6.1.4.1.4756.20.500.20.1.1683 | ColumnnidL2CPPort1DMAC0180C2000022Local | read-write | current | NID Series card Port 1 L2CP Mode 0180C2000022 0: Forward 1: Discard 2: Peer |
| 1.3.6.1.4.1.4756.20.500.20.1.1684 | ColumnnidL2CPPort1DMAC0180C2000023Local | read-write | current | NID Series card Port 1 L2CP Mode 0180C2000023 0: Forward 1: Discard 2: Peer |
| 1.3.6.1.4.1.4756.20.500.20.1.1685 | ColumnnidL2CPPort1DMAC0180C2000024Local | read-write | current | NID Series card Port 1 L2CP Mode 0180C2000024 0: Forward 1: Discard 2: Peer |
| 1.3.6.1.4.1.4756.20.500.20.1.1686 | ColumnnidL2CPPort1DMAC0180C2000025Local | read-write | current | NID Series card Port 1 L2CP Mode 0180C2000025 0: Forward 1: Discard 2: Peer |
| 1.3.6.1.4.1.4756.20.500.20.1.1687 | ColumnnidL2CPPort1DMAC0180C2000026Local | read-write | current | NID Series card Port 1 L2CP Mode 0180C2000026 0: Forward 1: Discard 2: Peer |
| 1.3.6.1.4.1.4756.20.500.20.1.1688 | ColumnnidL2CPPort1DMAC0180C2000027Local | read-write | current | NID Series card Port 1 L2CP Mode 0180C2000027 0: Forward 1: Discard 2: Peer |
| 1.3.6.1.4.1.4756.20.500.20.1.1689 | ColumnnidL2CPPort1DMAC0180C2000028Local | read-write | current | NID Series card Port 1 L2CP Mode 0180C2000028 0: Forward 1: Discard 2: Peer |
| 1.3.6.1.4.1.4756.20.500.20.1.1690 | ColumnnidL2CPPort1DMAC0180C2000029Local | read-write | current | NID Series card Port 1 L2CP Mode 0180C2000029 0: Forward 1: Discard 2: Peer |
| 1.3.6.1.4.1.4756.20.500.20.1.1691 | ColumnnidL2CPPort1DMAC0180C200002ALocal | read-write | current | NID Series card Port 1 L2CP Mode 0180C200002A 0: Forward 1: Discard 2: Peer |
| 1.3.6.1.4.1.4756.20.500.20.1.1692 | ColumnnidL2CPPort1DMAC0180C200002BLocal | read-write | current | NID Series card Port 1 L2CP Mode 0180C200002B 0: Forward 1: Discard 2: Peer |
| 1.3.6.1.4.1.4756.20.500.20.1.1693 | ColumnnidL2CPPort1DMAC0180C200002CLocal | read-write | current | NID Series card Port 1 L2CP Mode 0180C200002C 0: Forward 1: Discard 2: Peer |
| 1.3.6.1.4.1.4756.20.500.20.1.1694 | ColumnnidL2CPPort1DMAC0180C200002DLocal | read-write | current | NID Series card Port 1 L2CP Mode 0180C200002D 0: Forward 1: Discard 2: Peer |
| 1.3.6.1.4.1.4756.20.500.20.1.1695 | ColumnnidL2CPPort1DMAC0180C200002ELocal | read-write | current | NID Series card Port 1 L2CP Mode 0180C200002E 0: Forward 1: Discard 2: Peer |
| 1.3.6.1.4.1.4756.20.500.20.1.1696 | ColumnnidL2CPPort1DMAC0180C200002FLocal | read-write | current | NID Series card Port 1 L2CP Mode 0180C200002F 0: Forward 1: Discard 1: Peer |
| 1.3.6.1.4.1.4756.20.500.20.1.1697 | ColumnnidL2CPPort2DMAC0180C2000000Local | read-write | current | NID Series card Port 2 L2CP Mode 0180C2000000 0: Forward 1: Discard 2: Peer |
| 1.3.6.1.4.1.4756.20.500.20.1.1698 | ColumnnidL2CPPort2DMAC0180C2000001Local | read-write | current | NID Series card Port 2 L2CP Mode 0180C2000001 0: Forward 1: Discard 2: Peer |
| 1.3.6.1.4.1.4756.20.500.20.1.1699 | ColumnnidL2CPPort2DMAC0180C2000002Local | read-write | current | NID Series card Port 2 L2CP Mode 0180C2000002 0: Forward 1: Discard 2: Peer |
| 1.3.6.1.4.1.4756.20.500.20.1.1700 | ColumnnidL2CPPort2DMAC0180C2000003Local | read-write | current | NID Series card Port 2 L2CP Mode 0180C2000003 0: Forward 1: Discard 2: Peer |
| 1.3.6.1.4.1.4756.20.500.20.1.1701 | ColumnnidL2CPPort2DMAC0180C2000004Local | read-write | current | NID Series card Port 2 L2CP Mode 0180C2000004 0: Forward 1: Discard 2: Peer |
| 1.3.6.1.4.1.4756.20.500.20.1.1702 | ColumnnidL2CPPort2DMAC0180C2000005Local | read-write | current | NID Series card Port 2 L2CP Mode 0180C2000005 0: Forward 1: Discard 2: Peer |
| 1.3.6.1.4.1.4756.20.500.20.1.1703 | ColumnnidL2CPPort2DMAC0180C2000006Local | read-write | current | NID Series card Port 2 L2CP Mode 0180C2000006 0: Forward 1: Discard 2: Peer |
| 1.3.6.1.4.1.4756.20.500.20.1.1704 | ColumnnidL2CPPort2DMAC0180C2000007Local | read-write | current | NID Series card Port 2 L2CP Mode 0180C2000007 0: Forward 1: Discard 2: Peer |
| 1.3.6.1.4.1.4756.20.500.20.1.1705 | ColumnnidL2CPPort2DMAC0180C2000008Local | read-write | current | NID Series card Port 2 L2CP Mode 0180C2000008 0: Forward 1: Discard 2: Peer |
| 1.3.6.1.4.1.4756.20.500.20.1.1706 | ColumnnidL2CPPort2DMAC0180C2000009Local | read-write | current | NID Series card Port 2 L2CP Mode 0180C2000009 0: Forward 1: Discard 2: Peer |
| 1.3.6.1.4.1.4756.20.500.20.1.1707 | ColumnnidL2CPPort2DMAC0180C200000ALocal | read-write | current | NID Series card Port 2 L2CP Mode 0180C200000A 0: Forward 1: Discard 2: Peer |
| 1.3.6.1.4.1.4756.20.500.20.1.1708 | ColumnnidL2CPPort2DMAC0180C200000BLocal | read-write | current | NID Series card Port 2 L2CP Mode 0180C200000B 0: Forward 1: Discard 2: Peer |
| 1.3.6.1.4.1.4756.20.500.20.1.1709 | ColumnnidL2CPPort2DMAC0180C200000CLocal | read-write | current | NID Series card Port 2 L2CP Mode 0180C200000C 0: Forward 1: Discard 2: Peer |
| 1.3.6.1.4.1.4756.20.500.20.1.1710 | ColumnnidL2CPPort2DMAC0180C200000DLocal | read-write | current | NID Series card Port 2 L2CP Mode 0180C200000D 0: Forward 1: Discard 2: Peer |
| 1.3.6.1.4.1.4756.20.500.20.1.1711 | ColumnnidL2CPPort2DMAC0180C200000ELocal | read-write | current | NID Series card Port 2 L2CP Mode 0180C200000E 0: Forward 1: Discard 2: Peer |
| 1.3.6.1.4.1.4756.20.500.20.1.1712 | ColumnnidL2CPPort2DMAC0180C200000FLocal | read-write | current | NID Series card Port 2 L2CP Mode 0180C200000F 0: Forward 1: Discard 2: Peer |
| 1.3.6.1.4.1.4756.20.500.20.1.1713 | ColumnnidL2CPPort2DMAC0180C2000010Local | read-write | current | NID Series card Port 2 L2CP Mode 0180C2000010 0: Forward 1: Discard 2: Peer |
| 1.3.6.1.4.1.4756.20.500.20.1.1714 | ColumnnidL2CPPort2DMAC0180C2000020Local | read-write | current | NID Series card Port 2 L2CP Mode 0180C2000020 0: Forward 1: Discard 2: Peer |
| 1.3.6.1.4.1.4756.20.500.20.1.1715 | ColumnnidL2CPPort2DMAC0180C2000021Local | read-write | current | NID Series card Port 2 L2CP Mode 0180C2000021 0: Forward 1: Discard 2: Peer |
| 1.3.6.1.4.1.4756.20.500.20.1.1716 | ColumnnidL2CPPort2DMAC0180C2000022Local | read-write | current | NID Series card Port 2 L2CP Mode 0180C2000022 0: Forward 1: Discard 2: Peer |
| 1.3.6.1.4.1.4756.20.500.20.1.1717 | ColumnnidL2CPPort2DMAC0180C2000023Local | read-write | current | NID Series card Port 2 L2CP Mode 0180C2000023 0: Forward 1: Discard 2: Peer |
| 1.3.6.1.4.1.4756.20.500.20.1.1718 | ColumnnidL2CPPort2DMAC0180C2000024Local | read-write | current | NID Series card Port 2 L2CP Mode 0180C2000024 0: Forward 1: Discard 2: Peer |
| 1.3.6.1.4.1.4756.20.500.20.1.1719 | ColumnnidL2CPPort2DMAC0180C2000025Local | read-write | current | NID Series card Port 2 L2CP Mode 0180C2000025 0: Forward 1: Discard 2: Peer |
| 1.3.6.1.4.1.4756.20.500.20.1.1720 | ColumnnidL2CPPort2DMAC0180C2000026Local | read-write | current | NID Series card Port 2 L2CP Mode 0180C2000026 0: Forward 1: Discard 2: Peer |
| 1.3.6.1.4.1.4756.20.500.20.1.1721 | ColumnnidL2CPPort2DMAC0180C2000027Local | read-write | current | NID Series card Port 2 L2CP Mode 0180C2000027 0: Forward 1: Discard 2: Peer |
| 1.3.6.1.4.1.4756.20.500.20.1.1722 | ColumnnidL2CPPort2DMAC0180C2000028Local | read-write | current | NID Series card Port 2 L2CP Mode 0180C2000028 0: Forward 1: Discard 2: Peer |
| 1.3.6.1.4.1.4756.20.500.20.1.1723 | ColumnnidL2CPPort2DMAC0180C2000029Local | read-write | current | NID Series card Port 2 L2CP Mode 0180C2000029 0: Forward 1: Discard 2: Peer |
| 1.3.6.1.4.1.4756.20.500.20.1.1724 | ColumnnidL2CPPort2DMAC0180C200002ALocal | read-write | current | NID Series card Port 2 L2CP Mode 0180C200002A 0: Forward 1: Discard 2: Peer |
| 1.3.6.1.4.1.4756.20.500.20.1.1725 | ColumnnidL2CPPort2DMAC0180C200002BLocal | read-write | current | NID Series card Port 2 L2CP Mode 0180C200002B 0: Forward 1: Discard 2: Peer |
| 1.3.6.1.4.1.4756.20.500.20.1.1726 | ColumnnidL2CPPort2DMAC0180C200002CLocal | read-write | current | NID Series card Port 2 L2CP Mode 0180C200002C 0: Forward 1: Discard 2: Peer |
| 1.3.6.1.4.1.4756.20.500.20.1.1727 | ColumnnidL2CPPort2DMAC0180C200002DLocal | read-write | current | NID Series card Port 2 L2CP Mode 0180C200002D 0: Forward 1: Discard 2: Peer |
| 1.3.6.1.4.1.4756.20.500.20.1.1728 | ColumnnidL2CPPort2DMAC0180C200002ELocal | read-write | current | NID Series card Port 2 L2CP Mode 0180C200002E 0: Forward 1: Discard 2: Peer |
| 1.3.6.1.4.1.4756.20.500.20.1.1729 | ColumnnidL2CPPort2DMAC0180C200002FLocal | read-write | current | NID Series card Port 2 L2CP Mode 0180C200002F 0: Forward 1: Discard 1: Peer |
| 1.3.6.1.4.1.4756.20.500.20.1.1730 | ColumnnidL2CPPort3DMAC0180C2000000Local | read-write | current | NID Series card Port 3 L2CP Mode 0180C2000000 0: Forward 1: Discard 2: Peer |
| 1.3.6.1.4.1.4756.20.500.20.1.1731 | ColumnnidL2CPPort3DMAC0180C2000001Local | read-write | current | NID Series card Port 3 L2CP Mode 0180C2000001 0: Forward 1: Discard 2: Peer |
| 1.3.6.1.4.1.4756.20.500.20.1.1732 | ColumnnidL2CPPort3DMAC0180C2000002Local | read-write | current | NID Series card Port 3 L2CP Mode 0180C2000002 0: Forward 1: Discard 2: Peer |
| 1.3.6.1.4.1.4756.20.500.20.1.1733 | ColumnnidL2CPPort3DMAC0180C2000003Local | read-write | current | NID Series card Port 3 L2CP Mode 0180C2000003 0: Forward 1: Discard 2: Peer |
| 1.3.6.1.4.1.4756.20.500.20.1.1734 | ColumnnidL2CPPort3DMAC0180C2000004Local | read-write | current | NID Series card Port 3 L2CP Mode 0180C2000004 0: Forward 1: Discard 2: Peer |
| 1.3.6.1.4.1.4756.20.500.20.1.1735 | ColumnnidL2CPPort3DMAC0180C2000005Local | read-write | current | NID Series card Port 3 L2CP Mode 0180C2000005 0: Forward 1: Discard 2: Peer |
| 1.3.6.1.4.1.4756.20.500.20.1.1736 | ColumnnidL2CPPort3DMAC0180C2000006Local | read-write | current | NID Series card Port 3 L2CP Mode 0180C2000006 0: Forward 1: Discard 2: Peer |
| 1.3.6.1.4.1.4756.20.500.20.1.1737 | ColumnnidL2CPPort3DMAC0180C2000007Local | read-write | current | NID Series card Port 3 L2CP Mode 0180C2000007 0: Forward 1: Discard 2: Peer |
| 1.3.6.1.4.1.4756.20.500.20.1.1738 | ColumnnidL2CPPort3DMAC0180C2000008Local | read-write | current | NID Series card Port 3 L2CP Mode 0180C2000008 0: Forward 1: Discard 2: Peer |
| 1.3.6.1.4.1.4756.20.500.20.1.1739 | ColumnnidL2CPPort3DMAC0180C2000009Local | read-write | current | NID Series card Port 3 L2CP Mode 0180C2000009 0: Forward 1: Discard 2: Peer |
| 1.3.6.1.4.1.4756.20.500.20.1.1740 | ColumnnidL2CPPort3DMAC0180C200000ALocal | read-write | current | NID Series card Port 3 L2CP Mode 0180C200000A 0: Forward 1: Discard 2: Peer |
| 1.3.6.1.4.1.4756.20.500.20.1.1741 | ColumnnidL2CPPort3DMAC0180C200000BLocal | read-write | current | NID Series card Port 3 L2CP Mode 0180C200000B 0: Forward 1: Discard 2: Peer |
| 1.3.6.1.4.1.4756.20.500.20.1.1742 | ColumnnidL2CPPort3DMAC0180C200000CLocal | read-write | current | NID Series card Port 3 L2CP Mode 0180C200000C 0: Forward 1: Discard 2: Peer |
| 1.3.6.1.4.1.4756.20.500.20.1.1743 | ColumnnidL2CPPort3DMAC0180C200000DLocal | read-write | current | NID Series card Port 3 L2CP Mode 0180C200000D 0: Forward 1: Discard 2: Peer |
| 1.3.6.1.4.1.4756.20.500.20.1.1744 | ColumnnidL2CPPort3DMAC0180C200000ELocal | read-write | current | NID Series card Port 3 L2CP Mode 0180C200000E 0: Forward 1: Discard 2: Peer |
| 1.3.6.1.4.1.4756.20.500.20.1.1745 | ColumnnidL2CPPort3DMAC0180C200000FLocal | read-write | current | NID Series card Port 3 L2CP Mode 0180C200000F 0: Forward 1: Discard 2: Peer |
| 1.3.6.1.4.1.4756.20.500.20.1.1746 | ColumnnidL2CPPort3DMAC0180C2000010Local | read-write | current | NID Series card Port 3 L2CP Mode 0180C2000010 0: Forward 1: Discard 2: Peer |
| 1.3.6.1.4.1.4756.20.500.20.1.1747 | ColumnnidL2CPPort3DMAC0180C2000020Local | read-write | current | NID Series card Port 3 L2CP Mode 0180C2000020 0: Forward 1: Discard 2: Peer |
| 1.3.6.1.4.1.4756.20.500.20.1.1748 | ColumnnidL2CPPort3DMAC0180C2000021Local | read-write | current | NID Series card Port 3 L2CP Mode 0180C2000021 0: Forward 1: Discard 2: Peer |
| 1.3.6.1.4.1.4756.20.500.20.1.1749 | ColumnnidL2CPPort3DMAC0180C2000022Local | read-write | current | NID Series card Port 3 L2CP Mode 0180C2000022 0: Forward 1: Discard 2: Peer |
| 1.3.6.1.4.1.4756.20.500.20.1.1750 | ColumnnidL2CPPort3DMAC0180C2000023Local | read-write | current | NID Series card Port 3 L2CP Mode 0180C2000023 0: Forward 1: Discard 2: Peer |
| 1.3.6.1.4.1.4756.20.500.20.1.1751 | ColumnnidL2CPPort3DMAC0180C2000024Local | read-write | current | NID Series card Port 3 L2CP Mode 0180C2000024 0: Forward 1: Discard 2: Peer |
| 1.3.6.1.4.1.4756.20.500.20.1.1752 | ColumnnidL2CPPort3DMAC0180C2000025Local | read-write | current | NID Series card Port 3 L2CP Mode 0180C2000025 0: Forward 1: Discard 2: Peer |
| 1.3.6.1.4.1.4756.20.500.20.1.1753 | ColumnnidL2CPPort3DMAC0180C2000026Local | read-write | current | NID Series card Port 3 L2CP Mode 0180C2000026 0: Forward 1: Discard 2: Peer |
| 1.3.6.1.4.1.4756.20.500.20.1.1754 | ColumnnidL2CPPort3DMAC0180C2000027Local | read-write | current | NID Series card Port 3 L2CP Mode 0180C2000027 0: Forward 1: Discard 2: Peer |
| 1.3.6.1.4.1.4756.20.500.20.1.1755 | ColumnnidL2CPPort3DMAC0180C2000028Local | read-write | current | NID Series card Port 3 L2CP Mode 0180C2000028 0: Forward 1: Discard 2: Peer |
| 1.3.6.1.4.1.4756.20.500.20.1.1756 | ColumnnidL2CPPort3DMAC0180C2000029Local | read-write | current | NID Series card Port 3 L2CP Mode 0180C2000029 0: Forward 1: Discard 2: Peer |
| 1.3.6.1.4.1.4756.20.500.20.1.1757 | ColumnnidL2CPPort3DMAC0180C200002ALocal | read-write | current | NID Series card Port 3 L2CP Mode 0180C200002A 0: Forward 1: Discard 2: Peer |
| 1.3.6.1.4.1.4756.20.500.20.1.1758 | ColumnnidL2CPPort3DMAC0180C200002BLocal | read-write | current | NID Series card Port 3 L2CP Mode 0180C200002B 0: Forward 1: Discard 2: Peer |
| 1.3.6.1.4.1.4756.20.500.20.1.1759 | ColumnnidL2CPPort3DMAC0180C200002CLocal | read-write | current | NID Series card Port 3 L2CP Mode 0180C200002C 0: Forward 1: Discard 2: Peer |
| 1.3.6.1.4.1.4756.20.500.20.1.1760 | ColumnnidL2CPPort3DMAC0180C200002DLocal | read-write | current | NID Series card Port 3 L2CP Mode 0180C200002D 0: Forward 1: Discard 2: Peer |
| 1.3.6.1.4.1.4756.20.500.20.1.1761 | ColumnnidL2CPPort3DMAC0180C200002ELocal | read-write | current | NID Series card Port 3 L2CP Mode 0180C200002E 0: Forward 1: Discard 2: Peer |
| 1.3.6.1.4.1.4756.20.500.20.1.1762 | ColumnnidL2CPPort3DMAC0180C200002FLocal | read-write | current | NID Series card Port 3 L2CP Mode 0180C200002F 0: Forward 1: Discard 1: Peer |
| 1.3.6.1.4.1.4756.20.500.20.1.1763 | ColumnnidL2CPPort4DMAC0180C2000000Local | read-write | current | NID Series card Port 4 L2CP Mode 0180C2000000 0: Forward 1: Discard 2: Peer |
| 1.3.6.1.4.1.4756.20.500.20.1.1764 | ColumnnidL2CPPort4DMAC0180C2000001Local | read-write | current | NID Series card Port 4 L2CP Mode 0180C2000001 0: Forward 1: Discard 2: Peer |
| 1.3.6.1.4.1.4756.20.500.20.1.1765 | ColumnnidL2CPPort4DMAC0180C2000002Local | read-write | current | NID Series card Port 4 L2CP Mode 0180C2000002 0: Forward 1: Discard 2: Peer |
| 1.3.6.1.4.1.4756.20.500.20.1.1766 | ColumnnidL2CPPort4DMAC0180C2000003Local | read-write | current | NID Series card Port 4 L2CP Mode 0180C2000003 0: Forward 1: Discard 2: Peer |
| 1.3.6.1.4.1.4756.20.500.20.1.1767 | ColumnnidL2CPPort4DMAC0180C2000004Local | read-write | current | NID Series card Port 4 L2CP Mode 0180C2000004 0: Forward 1: Discard 2: Peer |
| 1.3.6.1.4.1.4756.20.500.20.1.1768 | ColumnnidL2CPPort4DMAC0180C2000005Local | read-write | current | NID Series card Port 4 L2CP Mode 0180C2000005 0: Forward 1: Discard 2: Peer |
| 1.3.6.1.4.1.4756.20.500.20.1.1769 | ColumnnidL2CPPort4DMAC0180C2000006Local | read-write | current | NID Series card Port 4 L2CP Mode 0180C2000006 0: Forward 1: Discard 2: Peer |
| 1.3.6.1.4.1.4756.20.500.20.1.1770 | ColumnnidL2CPPort4DMAC0180C2000007Local | read-write | current | NID Series card Port 4 L2CP Mode 0180C2000007 0: Forward 1: Discard 2: Peer |
| 1.3.6.1.4.1.4756.20.500.20.1.1771 | ColumnnidL2CPPort4DMAC0180C2000008Local | read-write | current | NID Series card Port 4 L2CP Mode 0180C2000008 0: Forward 1: Discard 2: Peer |
| 1.3.6.1.4.1.4756.20.500.20.1.1772 | ColumnnidL2CPPort4DMAC0180C2000009Local | read-write | current | NID Series card Port 4 L2CP Mode 0180C2000009 0: Forward 1: Discard 2: Peer |
| 1.3.6.1.4.1.4756.20.500.20.1.1773 | ColumnnidL2CPPort4DMAC0180C200000ALocal | read-write | current | NID Series card Port 4 L2CP Mode 0180C200000A 0: Forward 1: Discard 2: Peer |
| 1.3.6.1.4.1.4756.20.500.20.1.1774 | ColumnnidL2CPPort4DMAC0180C200000BLocal | read-write | current | NID Series card Port 4 L2CP Mode 0180C200000B 0: Forward 1: Discard 2: Peer |
| 1.3.6.1.4.1.4756.20.500.20.1.1775 | ColumnnidL2CPPort4DMAC0180C200000CLocal | read-write | current | NID Series card Port 4 L2CP Mode 0180C200000C 0: Forward 1: Discard 2: Peer |
| 1.3.6.1.4.1.4756.20.500.20.1.1776 | ColumnnidL2CPPort4DMAC0180C200000DLocal | read-write | current | NID Series card Port 4 L2CP Mode 0180C200000D 0: Forward 1: Discard 2: Peer |
| 1.3.6.1.4.1.4756.20.500.20.1.1777 | ColumnnidL2CPPort4DMAC0180C200000ELocal | read-write | current | NID Series card Port 4 L2CP Mode 0180C200000E 0: Forward 1: Discard 2: Peer |
| 1.3.6.1.4.1.4756.20.500.20.1.1778 | ColumnnidL2CPPort4DMAC0180C200000FLocal | read-write | current | NID Series card Port 4 L2CP Mode 0180C200000F 0: Forward 1: Discard 2: Peer |
| 1.3.6.1.4.1.4756.20.500.20.1.1779 | ColumnnidL2CPPort4DMAC0180C2000010Local | read-write | current | NID Series card Port 4 L2CP Mode 0180C2000010 0: Forward 1: Discard 2: Peer |
| 1.3.6.1.4.1.4756.20.500.20.1.1780 | ColumnnidL2CPPort4DMAC0180C2000020Local | read-write | current | NID Series card Port 4 L2CP Mode 0180C2000020 0: Forward 1: Discard 2: Peer |
| 1.3.6.1.4.1.4756.20.500.20.1.1781 | ColumnnidL2CPPort4DMAC0180C2000021Local | read-write | current | NID Series card Port 4 L2CP Mode 0180C2000021 0: Forward 1: Discard 2: Peer |
| 1.3.6.1.4.1.4756.20.500.20.1.1782 | ColumnnidL2CPPort4DMAC0180C2000022Local | read-write | current | NID Series card Port 4 L2CP Mode 0180C2000022 0: Forward 1: Discard 2: Peer |
| 1.3.6.1.4.1.4756.20.500.20.1.1783 | ColumnnidL2CPPort4DMAC0180C2000023Local | read-write | current | NID Series card Port 4 L2CP Mode 0180C2000023 0: Forward 1: Discard 2: Peer |
| 1.3.6.1.4.1.4756.20.500.20.1.1784 | ColumnnidL2CPPort4DMAC0180C2000024Local | read-write | current | NID Series card Port 4 L2CP Mode 0180C2000024 0: Forward 1: Discard 2: Peer |
| 1.3.6.1.4.1.4756.20.500.20.1.1785 | ColumnnidL2CPPort4DMAC0180C2000025Local | read-write | current | NID Series card Port 4 L2CP Mode 0180C2000025 0: Forward 1: Discard 2: Peer |
| 1.3.6.1.4.1.4756.20.500.20.1.1786 | ColumnnidL2CPPort4DMAC0180C2000026Local | read-write | current | NID Series card Port 4 L2CP Mode 0180C2000026 0: Forward 1: Discard 2: Peer |
| 1.3.6.1.4.1.4756.20.500.20.1.1787 | ColumnnidL2CPPort4DMAC0180C2000027Local | read-write | current | NID Series card Port 4 L2CP Mode 0180C2000027 0: Forward 1: Discard 2: Peer |
| 1.3.6.1.4.1.4756.20.500.20.1.1788 | ColumnnidL2CPPort4DMAC0180C2000028Local | read-write | current | NID Series card Port 4 L2CP Mode 0180C2000028 0: Forward 1: Discard 2: Peer |
| 1.3.6.1.4.1.4756.20.500.20.1.1789 | ColumnnidL2CPPort4DMAC0180C2000029Local | read-write | current | NID Series card Port 4 L2CP Mode 0180C2000029 0: Forward 1: Discard 2: Peer |
| 1.3.6.1.4.1.4756.20.500.20.1.1790 | ColumnnidL2CPPort4DMAC0180C200002ALocal | read-write | current | NID Series card Port 4 L2CP Mode 0180C200002A 0: Forward 1: Discard 2: Peer |
| 1.3.6.1.4.1.4756.20.500.20.1.1791 | ColumnnidL2CPPort4DMAC0180C200002BLocal | read-write | current | NID Series card Port 4 L2CP Mode 0180C200002B 0: Forward 1: Discard 2: Peer |
| 1.3.6.1.4.1.4756.20.500.20.1.1792 | ColumnnidL2CPPort4DMAC0180C200002CLocal | read-write | current | NID Series card Port 4 L2CP Mode 0180C200002C 0: Forward 1: Discard 2: Peer |
| 1.3.6.1.4.1.4756.20.500.20.1.1793 | ColumnnidL2CPPort4DMAC0180C200002DLocal | read-write | current | NID Series card Port 4 L2CP Mode 0180C200002D 0: Forward 1: Discard 2: Peer |
| 1.3.6.1.4.1.4756.20.500.20.1.1794 | ColumnnidL2CPPort4DMAC0180C200002ELocal | read-write | current | NID Series card Port 4 L2CP Mode 0180C200002E 0: Forward 1: Discard 2: Peer |
| 1.3.6.1.4.1.4756.20.500.20.1.1795 | ColumnnidL2CPPort4DMAC0180C200002FLocal | read-write | current | NID Series card Port 4 L2CP Mode 0180C200002F 0: Forward 1: Discard 1: Peer |
| 1.3.6.1.4.1.4756.20.500.20.1.1796 | ColumnnidL2CPPort5DMAC0180C2000000Local | read-write | current | NID Series card Port 5 L2CP Mode 0180C2000000 0: Forward 1: Discard 2: Peer |
| 1.3.6.1.4.1.4756.20.500.20.1.1797 | ColumnnidL2CPPort5DMAC0180C2000001Local | read-write | current | NID Series card Port 5 L2CP Mode 0180C2000001 0: Forward 1: Discard 2: Peer |
| 1.3.6.1.4.1.4756.20.500.20.1.1798 | ColumnnidL2CPPort5DMAC0180C2000002Local | read-write | current | NID Series card Port 5 L2CP Mode 0180C2000002 0: Forward 1: Discard 2: Peer |
| 1.3.6.1.4.1.4756.20.500.20.1.1799 | ColumnnidL2CPPort5DMAC0180C2000003Local | read-write | current | NID Series card Port 5 L2CP Mode 0180C2000003 0: Forward 1: Discard 2: Peer |
| 1.3.6.1.4.1.4756.20.500.20.1.1800 | ColumnnidL2CPPort5DMAC0180C2000004Local | read-write | current | NID Series card Port 5 L2CP Mode 0180C2000004 0: Forward 1: Discard 2: Peer |
| 1.3.6.1.4.1.4756.20.500.20.1.1801 | ColumnnidL2CPPort5DMAC0180C2000005Local | read-write | current | NID Series card Port 5 L2CP Mode 0180C2000005 0: Forward 1: Discard 2: Peer |
| 1.3.6.1.4.1.4756.20.500.20.1.1802 | ColumnnidL2CPPort5DMAC0180C2000006Local | read-write | current | NID Series card Port 5 L2CP Mode 0180C2000006 0: Forward 1: Discard 2: Peer |
| 1.3.6.1.4.1.4756.20.500.20.1.1803 | ColumnnidL2CPPort5DMAC0180C2000007Local | read-write | current | NID Series card Port 5 L2CP Mode 0180C2000007 0: Forward 1: Discard 2: Peer |
| 1.3.6.1.4.1.4756.20.500.20.1.1804 | ColumnnidL2CPPort5DMAC0180C2000008Local | read-write | current | NID Series card Port 5 L2CP Mode 0180C2000008 0: Forward 1: Discard 2: Peer |
| 1.3.6.1.4.1.4756.20.500.20.1.1805 | ColumnnidL2CPPort5DMAC0180C2000009Local | read-write | current | NID Series card Port 5 L2CP Mode 0180C2000009 0: Forward 1: Discard 2: Peer |
| 1.3.6.1.4.1.4756.20.500.20.1.1806 | ColumnnidL2CPPort5DMAC0180C200000ALocal | read-write | current | NID Series card Port 5 L2CP Mode 0180C200000A 0: Forward 1: Discard 2: Peer |
| 1.3.6.1.4.1.4756.20.500.20.1.1807 | ColumnnidL2CPPort5DMAC0180C200000BLocal | read-write | current | NID Series card Port 5 L2CP Mode 0180C200000B 0: Forward 1: Discard 2: Peer |
| 1.3.6.1.4.1.4756.20.500.20.1.1808 | ColumnnidL2CPPort5DMAC0180C200000CLocal | read-write | current | NID Series card Port 5 L2CP Mode 0180C200000C 0: Forward 1: Discard 2: Peer |
| 1.3.6.1.4.1.4756.20.500.20.1.1809 | ColumnnidL2CPPort5DMAC0180C200000DLocal | read-write | current | NID Series card Port 5 L2CP Mode 0180C200000D 0: Forward 1: Discard 2: Peer |
| 1.3.6.1.4.1.4756.20.500.20.1.1810 | ColumnnidL2CPPort5DMAC0180C200000ELocal | read-write | current | NID Series card Port 5 L2CP Mode 0180C200000E 0: Forward 1: Discard 2: Peer |
| 1.3.6.1.4.1.4756.20.500.20.1.1811 | ColumnnidL2CPPort5DMAC0180C200000FLocal | read-write | current | NID Series card Port 5 L2CP Mode 0180C200000F 0: Forward 1: Discard 2: Peer |
| 1.3.6.1.4.1.4756.20.500.20.1.1812 | ColumnnidL2CPPort5DMAC0180C2000010Local | read-write | current | NID Series card Port 5 L2CP Mode 0180C2000010 0: Forward 1: Discard 2: Peer |
| 1.3.6.1.4.1.4756.20.500.20.1.1813 | ColumnnidL2CPPort5DMAC0180C2000020Local | read-write | current | NID Series card Port 5 L2CP Mode 0180C2000020 0: Forward 1: Discard 2: Peer |
| 1.3.6.1.4.1.4756.20.500.20.1.1814 | ColumnnidL2CPPort5DMAC0180C2000021Local | read-write | current | NID Series card Port 5 L2CP Mode 0180C2000021 0: Forward 1: Discard 2: Peer |
| 1.3.6.1.4.1.4756.20.500.20.1.1815 | ColumnnidL2CPPort5DMAC0180C2000022Local | read-write | current | NID Series card Port 5 L2CP Mode 0180C2000022 0: Forward 1: Discard 2: Peer |
| 1.3.6.1.4.1.4756.20.500.20.1.1816 | ColumnnidL2CPPort5DMAC0180C2000023Local | read-write | current | NID Series card Port 5 L2CP Mode 0180C2000023 0: Forward 1: Discard 2: Peer |
| 1.3.6.1.4.1.4756.20.500.20.1.1817 | ColumnnidL2CPPort5DMAC0180C2000024Local | read-write | current | NID Series card Port 5 L2CP Mode 0180C2000024 0: Forward 1: Discard 2: Peer |
| 1.3.6.1.4.1.4756.20.500.20.1.1818 | ColumnnidL2CPPort5DMAC0180C2000025Local | read-write | current | NID Series card Port 5 L2CP Mode 0180C2000025 0: Forward 1: Discard 2: Peer |
| 1.3.6.1.4.1.4756.20.500.20.1.1819 | ColumnnidL2CPPort5DMAC0180C2000026Local | read-write | current | NID Series card Port 5 L2CP Mode 0180C2000026 0: Forward 1: Discard 2: Peer |
| 1.3.6.1.4.1.4756.20.500.20.1.1820 | ColumnnidL2CPPort5DMAC0180C2000027Local | read-write | current | NID Series card Port 5 L2CP Mode 0180C2000027 0: Forward 1: Discard 2: Peer |
| 1.3.6.1.4.1.4756.20.500.20.1.1821 | ColumnnidL2CPPort5DMAC0180C2000028Local | read-write | current | NID Series card Port 5 L2CP Mode 0180C2000028 0: Forward 1: Discard 2: Peer |
| 1.3.6.1.4.1.4756.20.500.20.1.1822 | ColumnnidL2CPPort5DMAC0180C2000029Local | read-write | current | NID Series card Port 5 L2CP Mode 0180C2000029 0: Forward 1: Discard 2: Peer |
| 1.3.6.1.4.1.4756.20.500.20.1.1823 | ColumnnidL2CPPort5DMAC0180C200002ALocal | read-write | current | NID Series card Port 5 L2CP Mode 0180C200002A 0: Forward 1: Discard 2: Peer |
| 1.3.6.1.4.1.4756.20.500.20.1.1824 | ColumnnidL2CPPort5DMAC0180C200002BLocal | read-write | current | NID Series card Port 5 L2CP Mode 0180C200002B 0: Forward 1: Discard 2: Peer |
| 1.3.6.1.4.1.4756.20.500.20.1.1825 | ColumnnidL2CPPort5DMAC0180C200002CLocal | read-write | current | NID Series card Port 5 L2CP Mode 0180C200002C 0: Forward 1: Discard 2: Peer |
| 1.3.6.1.4.1.4756.20.500.20.1.1826 | ColumnnidL2CPPort5DMAC0180C200002DLocal | read-write | current | NID Series card Port 5 L2CP Mode 0180C200002D 0: Forward 1: Discard 2: Peer |
| 1.3.6.1.4.1.4756.20.500.20.1.1827 | ColumnnidL2CPPort5DMAC0180C200002ELocal | read-write | current | NID Series card Port 5 L2CP Mode 0180C200002E 0: Forward 1: Discard 2: Peer |
| 1.3.6.1.4.1.4756.20.500.20.1.1828 | ColumnnidL2CPPort5DMAC0180C200002FLocal | read-write | current | NID Series card Port 5 L2CP Mode 0180C200002F 0: Forward 1: Discard 1: Peer |
| 1.3.6.1.4.1.4756.20.500.20.1.1829 | ColumnnidL2CPPort6DMAC0180C2000000Local | read-write | current | NID Series card Port 6 L2CP Mode 0180C2000000 0: Forward 1: Discard 2: Peer |
| 1.3.6.1.4.1.4756.20.500.20.1.1830 | ColumnnidL2CPPort6DMAC0180C2000001Local | read-write | current | NID Series card Port 6 L2CP Mode 0180C2000001 0: Forward 1: Discard 2: Peer |
| 1.3.6.1.4.1.4756.20.500.20.1.1831 | ColumnnidL2CPPort6DMAC0180C2000002Local | read-write | current | NID Series card Port 6 L2CP Mode 0180C2000002 0: Forward 1: Discard 2: Peer |
| 1.3.6.1.4.1.4756.20.500.20.1.1832 | ColumnnidL2CPPort6DMAC0180C2000003Local | read-write | current | NID Series card Port 6 L2CP Mode 0180C2000003 0: Forward 1: Discard 2: Peer |
| 1.3.6.1.4.1.4756.20.500.20.1.1833 | ColumnnidL2CPPort6DMAC0180C2000004Local | read-write | current | NID Series card Port 6 L2CP Mode 0180C2000004 0: Forward 1: Discard 2: Peer |
| 1.3.6.1.4.1.4756.20.500.20.1.1834 | ColumnnidL2CPPort6DMAC0180C2000005Local | read-write | current | NID Series card Port 6 L2CP Mode 0180C2000005 0: Forward 1: Discard 2: Peer |
| 1.3.6.1.4.1.4756.20.500.20.1.1835 | ColumnnidL2CPPort6DMAC0180C2000006Local | read-write | current | NID Series card Port 6 L2CP Mode 0180C2000006 0: Forward 1: Discard 2: Peer |
| 1.3.6.1.4.1.4756.20.500.20.1.1836 | ColumnnidL2CPPort6DMAC0180C2000007Local | read-write | current | NID Series card Port 6 L2CP Mode 0180C2000007 0: Forward 1: Discard 2: Peer |
| 1.3.6.1.4.1.4756.20.500.20.1.1837 | ColumnnidL2CPPort6DMAC0180C2000008Local | read-write | current | NID Series card Port 6 L2CP Mode 0180C2000008 0: Forward 1: Discard 2: Peer |
| 1.3.6.1.4.1.4756.20.500.20.1.1838 | ColumnnidL2CPPort6DMAC0180C2000009Local | read-write | current | NID Series card Port 6 L2CP Mode 0180C2000009 0: Forward 1: Discard 2: Peer |
| 1.3.6.1.4.1.4756.20.500.20.1.1839 | ColumnnidL2CPPort6DMAC0180C200000ALocal | read-write | current | NID Series card Port 6 L2CP Mode 0180C200000A 0: Forward 1: Discard 2: Peer |
| 1.3.6.1.4.1.4756.20.500.20.1.1840 | ColumnnidL2CPPort6DMAC0180C200000BLocal | read-write | current | NID Series card Port 6 L2CP Mode 0180C200000B 0: Forward 1: Discard 2: Peer |
| 1.3.6.1.4.1.4756.20.500.20.1.1841 | ColumnnidL2CPPort6DMAC0180C200000CLocal | read-write | current | NID Series card Port 6 L2CP Mode 0180C200000C 0: Forward 1: Discard 2: Peer |
| 1.3.6.1.4.1.4756.20.500.20.1.1842 | ColumnnidL2CPPort6DMAC0180C200000DLocal | read-write | current | NID Series card Port 6 L2CP Mode 0180C200000D 0: Forward 1: Discard 2: Peer |
| 1.3.6.1.4.1.4756.20.500.20.1.1843 | ColumnnidL2CPPort6DMAC0180C200000ELocal | read-write | current | NID Series card Port 6 L2CP Mode 0180C200000E 0: Forward 1: Discard 2: Peer |
| 1.3.6.1.4.1.4756.20.500.20.1.1844 | ColumnnidL2CPPort6DMAC0180C200000FLocal | read-write | current | NID Series card Port 6 L2CP Mode 0180C200000F 0: Forward 1: Discard 2: Peer |
| 1.3.6.1.4.1.4756.20.500.20.1.1845 | ColumnnidL2CPPort6DMAC0180C2000010Local | read-write | current | NID Series card Port 6 L2CP Mode 0180C2000010 0: Forward 1: Discard 2: Peer |
| 1.3.6.1.4.1.4756.20.500.20.1.1846 | ColumnnidL2CPPort6DMAC0180C2000020Local | read-write | current | NID Series card Port 6 L2CP Mode 0180C2000020 0: Forward 1: Discard 2: Peer |
| 1.3.6.1.4.1.4756.20.500.20.1.1847 | ColumnnidL2CPPort6DMAC0180C2000021Local | read-write | current | NID Series card Port 6 L2CP Mode 0180C2000021 0: Forward 1: Discard 2: Peer |
| 1.3.6.1.4.1.4756.20.500.20.1.1848 | ColumnnidL2CPPort6DMAC0180C2000022Local | read-write | current | NID Series card Port 6 L2CP Mode 0180C2000022 0: Forward 1: Discard 2: Peer |
| 1.3.6.1.4.1.4756.20.500.20.1.1849 | ColumnnidL2CPPort6DMAC0180C2000023Local | read-write | current | NID Series card Port 6 L2CP Mode 0180C2000023 0: Forward 1: Discard 2: Peer |
| 1.3.6.1.4.1.4756.20.500.20.1.1850 | ColumnnidL2CPPort6DMAC0180C2000024Local | read-write | current | NID Series card Port 6 L2CP Mode 0180C2000024 0: Forward 1: Discard 2: Peer |
| 1.3.6.1.4.1.4756.20.500.20.1.1851 | ColumnnidL2CPPort6DMAC0180C2000025Local | read-write | current | NID Series card Port 6 L2CP Mode 0180C2000025 0: Forward 1: Discard 2: Peer |
| 1.3.6.1.4.1.4756.20.500.20.1.1852 | ColumnnidL2CPPort6DMAC0180C2000026Local | read-write | current | NID Series card Port 6 L2CP Mode 0180C2000026 0: Forward 1: Discard 2: Peer |
| 1.3.6.1.4.1.4756.20.500.20.1.1853 | ColumnnidL2CPPort6DMAC0180C2000027Local | read-write | current | NID Series card Port 6 L2CP Mode 0180C2000027 0: Forward 1: Discard 2: Peer |
| 1.3.6.1.4.1.4756.20.500.20.1.1854 | ColumnnidL2CPPort6DMAC0180C2000028Local | read-write | current | NID Series card Port 6 L2CP Mode 0180C2000028 0: Forward 1: Discard 2: Peer |
| 1.3.6.1.4.1.4756.20.500.20.1.1855 | ColumnnidL2CPPort6DMAC0180C2000029Local | read-write | current | NID Series card Port 6 L2CP Mode 0180C2000029 0: Forward 1: Discard 2: Peer |
| 1.3.6.1.4.1.4756.20.500.20.1.1856 | ColumnnidL2CPPort6DMAC0180C200002ALocal | read-write | current | NID Series card Port 6 L2CP Mode 0180C200002A 0: Forward 1: Discard 2: Peer |
| 1.3.6.1.4.1.4756.20.500.20.1.1857 | ColumnnidL2CPPort6DMAC0180C200002BLocal | read-write | current | NID Series card Port 6 L2CP Mode 0180C200002B 0: Forward 1: Discard 2: Peer |
| 1.3.6.1.4.1.4756.20.500.20.1.1858 | ColumnnidL2CPPort6DMAC0180C200002CLocal | read-write | current | NID Series card Port 6 L2CP Mode 0180C200002C 0: Forward 1: Discard 2: Peer |
| 1.3.6.1.4.1.4756.20.500.20.1.1859 | ColumnnidL2CPPort6DMAC0180C200002DLocal | read-write | current | NID Series card Port 6 L2CP Mode 0180C200002D 0: Forward 1: Discard 2: Peer |
| 1.3.6.1.4.1.4756.20.500.20.1.1860 | ColumnnidL2CPPort6DMAC0180C200002ELocal | read-write | current | NID Series card Port 6 L2CP Mode 0180C200002E 0: Forward 1: Discard 2: Peer |
| 1.3.6.1.4.1.4756.20.500.20.1.1861 | ColumnnidL2CPPort6DMAC0180C200002FLocal | read-write | current | NID Series card Port 6 L2CP Mode 0180C200002F 0: Forward 1: Discard 1: Peer |
| 1.3.6.1.4.1.4756.20.500.20.1.1862 | ColumnnidL2CPPort7DMAC0180C2000000Local | read-write | current | NID Series card Port 7 L2CP Mode 0180C2000000 0: Forward 1: Discard 2: Peer |
| 1.3.6.1.4.1.4756.20.500.20.1.1863 | ColumnnidL2CPPort7DMAC0180C2000001Local | read-write | current | NID Series card Port 7 L2CP Mode 0180C2000001 0: Forward 1: Discard 2: Peer |
| 1.3.6.1.4.1.4756.20.500.20.1.1864 | ColumnnidL2CPPort7DMAC0180C2000002Local | read-write | current | NID Series card Port 7 L2CP Mode 0180C2000002 0: Forward 1: Discard 2: Peer |
| 1.3.6.1.4.1.4756.20.500.20.1.1865 | ColumnnidL2CPPort7DMAC0180C2000003Local | read-write | current | NID Series card Port 7 L2CP Mode 0180C2000003 0: Forward 1: Discard 2: Peer |
| 1.3.6.1.4.1.4756.20.500.20.1.1866 | ColumnnidL2CPPort7DMAC0180C2000004Local | read-write | current | NID Series card Port 7 L2CP Mode 0180C2000004 0: Forward 1: Discard 2: Peer |
| 1.3.6.1.4.1.4756.20.500.20.1.1867 | ColumnnidL2CPPort7DMAC0180C2000005Local | read-write | current | NID Series card Port 7 L2CP Mode 0180C2000005 0: Forward 1: Discard 2: Peer |
| 1.3.6.1.4.1.4756.20.500.20.1.1868 | ColumnnidL2CPPort7DMAC0180C2000006Local | read-write | current | NID Series card Port 7 L2CP Mode 0180C2000006 0: Forward 1: Discard 2: Peer |
| 1.3.6.1.4.1.4756.20.500.20.1.1869 | ColumnnidL2CPPort7DMAC0180C2000007Local | read-write | current | NID Series card Port 7 L2CP Mode 0180C2000007 0: Forward 1: Discard 2: Peer |
| 1.3.6.1.4.1.4756.20.500.20.1.1870 | ColumnnidL2CPPort7DMAC0180C2000008Local | read-write | current | NID Series card Port 7 L2CP Mode 0180C2000008 0: Forward 1: Discard 2: Peer |
| 1.3.6.1.4.1.4756.20.500.20.1.1871 | ColumnnidL2CPPort7DMAC0180C2000009Local | read-write | current | NID Series card Port 7 L2CP Mode 0180C2000009 0: Forward 1: Discard 2: Peer |
| 1.3.6.1.4.1.4756.20.500.20.1.1872 | ColumnnidL2CPPort7DMAC0180C200000ALocal | read-write | current | NID Series card Port 7 L2CP Mode 0180C200000A 0: Forward 1: Discard 2: Peer |
| 1.3.6.1.4.1.4756.20.500.20.1.1873 | ColumnnidL2CPPort7DMAC0180C200000BLocal | read-write | current | NID Series card Port 7 L2CP Mode 0180C200000B 0: Forward 1: Discard 2: Peer |
| 1.3.6.1.4.1.4756.20.500.20.1.1874 | ColumnnidL2CPPort7DMAC0180C200000CLocal | read-write | current | NID Series card Port 7 L2CP Mode 0180C200000C 0: Forward 1: Discard 2: Peer |
| 1.3.6.1.4.1.4756.20.500.20.1.1875 | ColumnnidL2CPPort7DMAC0180C200000DLocal | read-write | current | NID Series card Port 7 L2CP Mode 0180C200000D 0: Forward 1: Discard 2: Peer |
| 1.3.6.1.4.1.4756.20.500.20.1.1876 | ColumnnidL2CPPort7DMAC0180C200000ELocal | read-write | current | NID Series card Port 7 L2CP Mode 0180C200000E 0: Forward 1: Discard 2: Peer |
| 1.3.6.1.4.1.4756.20.500.20.1.1877 | ColumnnidL2CPPort7DMAC0180C200000FLocal | read-write | current | NID Series card Port 7 L2CP Mode 0180C200000F 0: Forward 1: Discard 2: Peer |
| 1.3.6.1.4.1.4756.20.500.20.1.1878 | ColumnnidL2CPPort7DMAC0180C2000010Local | read-write | current | NID Series card Port 7 L2CP Mode 0180C2000010 0: Forward 1: Discard 2: Peer |
| 1.3.6.1.4.1.4756.20.500.20.1.1879 | ColumnnidL2CPPort7DMAC0180C2000020Local | read-write | current | NID Series card Port 7 L2CP Mode 0180C2000020 0: Forward 1: Discard 2: Peer |
| 1.3.6.1.4.1.4756.20.500.20.1.1880 | ColumnnidL2CPPort7DMAC0180C2000021Local | read-write | current | NID Series card Port 7 L2CP Mode 0180C2000021 0: Forward 1: Discard 2: Peer |
| 1.3.6.1.4.1.4756.20.500.20.1.1881 | ColumnnidL2CPPort7DMAC0180C2000022Local | read-write | current | NID Series card Port 7 L2CP Mode 0180C2000022 0: Forward 1: Discard 2: Peer |
| 1.3.6.1.4.1.4756.20.500.20.1.1882 | ColumnnidL2CPPort7DMAC0180C2000023Local | read-write | current | NID Series card Port 7 L2CP Mode 0180C2000023 0: Forward 1: Discard 2: Peer |
| 1.3.6.1.4.1.4756.20.500.20.1.1883 | ColumnnidL2CPPort7DMAC0180C2000024Local | read-write | current | NID Series card Port 7 L2CP Mode 0180C2000024 0: Forward 1: Discard 2: Peer |
| 1.3.6.1.4.1.4756.20.500.20.1.1884 | ColumnnidL2CPPort7DMAC0180C2000025Local | read-write | current | NID Series card Port 7 L2CP Mode 0180C2000025 0: Forward 1: Discard 2: Peer |
| 1.3.6.1.4.1.4756.20.500.20.1.1885 | ColumnnidL2CPPort7DMAC0180C2000026Local | read-write | current | NID Series card Port 7 L2CP Mode 0180C2000026 0: Forward 1: Discard 2: Peer |
| 1.3.6.1.4.1.4756.20.500.20.1.1886 | ColumnnidL2CPPort7DMAC0180C2000027Local | read-write | current | NID Series card Port 7 L2CP Mode 0180C2000027 0: Forward 1: Discard 2: Peer |
| 1.3.6.1.4.1.4756.20.500.20.1.1887 | ColumnnidL2CPPort7DMAC0180C2000028Local | read-write | current | NID Series card Port 7 L2CP Mode 0180C2000028 0: Forward 1: Discard 2: Peer |
| 1.3.6.1.4.1.4756.20.500.20.1.1888 | ColumnnidL2CPPort7DMAC0180C2000029Local | read-write | current | NID Series card Port 7 L2CP Mode 0180C2000029 0: Forward 1: Discard 2: Peer |
| 1.3.6.1.4.1.4756.20.500.20.1.1889 | ColumnnidL2CPPort7DMAC0180C200002ALocal | read-write | current | NID Series card Port 7 L2CP Mode 0180C200002A 0: Forward 1: Discard 2: Peer |
| 1.3.6.1.4.1.4756.20.500.20.1.1890 | ColumnnidL2CPPort7DMAC0180C200002BLocal | read-write | current | NID Series card Port 7 L2CP Mode 0180C200002B 0: Forward 1: Discard 2: Peer |
| 1.3.6.1.4.1.4756.20.500.20.1.1891 | ColumnnidL2CPPort7DMAC0180C200002CLocal | read-write | current | NID Series card Port 7 L2CP Mode 0180C200002C 0: Forward 1: Discard 2: Peer |
| 1.3.6.1.4.1.4756.20.500.20.1.1892 | ColumnnidL2CPPort7DMAC0180C200002DLocal | read-write | current | NID Series card Port 7 L2CP Mode 0180C200002D 0: Forward 1: Discard 2: Peer |
| 1.3.6.1.4.1.4756.20.500.20.1.1893 | ColumnnidL2CPPort7DMAC0180C200002ELocal | read-write | current | NID Series card Port 7 L2CP Mode 0180C200002E 0: Forward 1: Discard 2: Peer |
| 1.3.6.1.4.1.4756.20.500.20.1.1894 | ColumnnidL2CPPort7DMAC0180C200002FLocal | read-write | current | NID Series card Port 7 L2CP Mode 0180C200002F 0: Forward 1: Discard 1: Peer |
| 1.3.6.1.4.1.4756.20.500.20.1.1895 | ColumnnidL2CPPort8DMAC0180C2000000Local | read-write | current | NID Series card Port 8 L2CP Mode 0180C2000000 0: Forward 1: Discard 2: Peer |
| 1.3.6.1.4.1.4756.20.500.20.1.1896 | ColumnnidL2CPPort8DMAC0180C2000001Local | read-write | current | NID Series card Port 8 L2CP Mode 0180C2000001 0: Forward 1: Discard 2: Peer |
| 1.3.6.1.4.1.4756.20.500.20.1.1897 | ColumnnidL2CPPort8DMAC0180C2000002Local | read-write | current | NID Series card Port 8 L2CP Mode 0180C2000002 0: Forward 1: Discard 2: Peer |
| 1.3.6.1.4.1.4756.20.500.20.1.1898 | ColumnnidL2CPPort8DMAC0180C2000003Local | read-write | current | NID Series card Port 8 L2CP Mode 0180C2000003 0: Forward 1: Discard 2: Peer |
| 1.3.6.1.4.1.4756.20.500.20.1.1899 | ColumnnidL2CPPort8DMAC0180C2000004Local | read-write | current | NID Series card Port 8 L2CP Mode 0180C2000004 0: Forward 1: Discard 2: Peer |
| 1.3.6.1.4.1.4756.20.500.20.1.1900 | ColumnnidL2CPPort8DMAC0180C2000005Local | read-write | current | NID Series card Port 8 L2CP Mode 0180C2000005 0: Forward 1: Discard 2: Peer |
| 1.3.6.1.4.1.4756.20.500.20.1.1901 | ColumnnidL2CPPort8DMAC0180C2000006Local | read-write | current | NID Series card Port 8 L2CP Mode 0180C2000006 0: Forward 1: Discard 2: Peer |
| 1.3.6.1.4.1.4756.20.500.20.1.1902 | ColumnnidL2CPPort8DMAC0180C2000007Local | read-write | current | NID Series card Port 8 L2CP Mode 0180C2000007 0: Forward 1: Discard 2: Peer |
| 1.3.6.1.4.1.4756.20.500.20.1.1903 | ColumnnidL2CPPort8DMAC0180C2000008Local | read-write | current | NID Series card Port 8 L2CP Mode 0180C2000008 0: Forward 1: Discard 2: Peer |
| 1.3.6.1.4.1.4756.20.500.20.1.1904 | ColumnnidL2CPPort8DMAC0180C2000009Local | read-write | current | NID Series card Port 8 L2CP Mode 0180C2000009 0: Forward 1: Discard 2: Peer |
| 1.3.6.1.4.1.4756.20.500.20.1.1905 | ColumnnidL2CPPort8DMAC0180C200000ALocal | read-write | current | NID Series card Port 8 L2CP Mode 0180C200000A 0: Forward 1: Discard 2: Peer |
| 1.3.6.1.4.1.4756.20.500.20.1.1906 | ColumnnidL2CPPort8DMAC0180C200000BLocal | read-write | current | NID Series card Port 8 L2CP Mode 0180C200000B 0: Forward 1: Discard 2: Peer |
| 1.3.6.1.4.1.4756.20.500.20.1.1907 | ColumnnidL2CPPort8DMAC0180C200000CLocal | read-write | current | NID Series card Port 8 L2CP Mode 0180C200000C 0: Forward 1: Discard 2: Peer |
| 1.3.6.1.4.1.4756.20.500.20.1.1908 | ColumnnidL2CPPort8DMAC0180C200000DLocal | read-write | current | NID Series card Port 8 L2CP Mode 0180C200000D 0: Forward 1: Discard 2: Peer |
| 1.3.6.1.4.1.4756.20.500.20.1.1909 | ColumnnidL2CPPort8DMAC0180C200000ELocal | read-write | current | NID Series card Port 8 L2CP Mode 0180C200000E 0: Forward 1: Discard 2: Peer |
| 1.3.6.1.4.1.4756.20.500.20.1.1910 | ColumnnidL2CPPort8DMAC0180C200000FLocal | read-write | current | NID Series card Port 8 L2CP Mode 0180C200000F 0: Forward 1: Discard 2: Peer |
| 1.3.6.1.4.1.4756.20.500.20.1.1911 | ColumnnidL2CPPort8DMAC0180C2000010Local | read-write | current | NID Series card Port 8 L2CP Mode 0180C2000010 0: Forward 1: Discard 2: Peer |
| 1.3.6.1.4.1.4756.20.500.20.1.1912 | ColumnnidL2CPPort8DMAC0180C2000020Local | read-write | current | NID Series card Port 8 L2CP Mode 0180C2000020 0: Forward 1: Discard 2: Peer |
| 1.3.6.1.4.1.4756.20.500.20.1.1913 | ColumnnidL2CPPort8DMAC0180C2000021Local | read-write | current | NID Series card Port 8 L2CP Mode 0180C2000021 0: Forward 1: Discard 2: Peer |
| 1.3.6.1.4.1.4756.20.500.20.1.1914 | ColumnnidL2CPPort8DMAC0180C2000022Local | read-write | current | NID Series card Port 8 L2CP Mode 0180C2000022 0: Forward 1: Discard 2: Peer |
| 1.3.6.1.4.1.4756.20.500.20.1.1915 | ColumnnidL2CPPort8DMAC0180C2000023Local | read-write | current | NID Series card Port 8 L2CP Mode 0180C2000023 0: Forward 1: Discard 2: Peer |
| 1.3.6.1.4.1.4756.20.500.20.1.1916 | ColumnnidL2CPPort8DMAC0180C2000024Local | read-write | current | NID Series card Port 8 L2CP Mode 0180C2000024 0: Forward 1: Discard 2: Peer |
| 1.3.6.1.4.1.4756.20.500.20.1.1917 | ColumnnidL2CPPort8DMAC0180C2000025Local | read-write | current | NID Series card Port 8 L2CP Mode 0180C2000025 0: Forward 1: Discard 2: Peer |
| 1.3.6.1.4.1.4756.20.500.20.1.1918 | ColumnnidL2CPPort8DMAC0180C2000026Local | read-write | current | NID Series card Port 8 L2CP Mode 0180C2000026 0: Forward 1: Discard 2: Peer |
| 1.3.6.1.4.1.4756.20.500.20.1.1919 | ColumnnidL2CPPort8DMAC0180C2000027Local | read-write | current | NID Series card Port 8 L2CP Mode 0180C2000027 0: Forward 1: Discard 2: Peer |
| 1.3.6.1.4.1.4756.20.500.20.1.1920 | ColumnnidL2CPPort8DMAC0180C2000028Local | read-write | current | NID Series card Port 8 L2CP Mode 0180C2000028 0: Forward 1: Discard 2: Peer |
| 1.3.6.1.4.1.4756.20.500.20.1.1921 | ColumnnidL2CPPort8DMAC0180C2000029Local | read-write | current | NID Series card Port 8 L2CP Mode 0180C2000029 0: Forward 1: Discard 2: Peer |
| 1.3.6.1.4.1.4756.20.500.20.1.1922 | ColumnnidL2CPPort8DMAC0180C200002ALocal | read-write | current | NID Series card Port 8 L2CP Mode 0180C200002A 0: Forward 1: Discard 2: Peer |
| 1.3.6.1.4.1.4756.20.500.20.1.1923 | ColumnnidL2CPPort8DMAC0180C200002BLocal | read-write | current | NID Series card Port 8 L2CP Mode 0180C200002B 0: Forward 1: Discard 2: Peer |
| 1.3.6.1.4.1.4756.20.500.20.1.1924 | ColumnnidL2CPPort8DMAC0180C200002CLocal | read-write | current | NID Series card Port 8 L2CP Mode 0180C200002C 0: Forward 1: Discard 2: Peer |
| 1.3.6.1.4.1.4756.20.500.20.1.1925 | ColumnnidL2CPPort8DMAC0180C200002DLocal | read-write | current | NID Series card Port 8 L2CP Mode 0180C200002D 0: Forward 1: Discard 2: Peer |
| 1.3.6.1.4.1.4756.20.500.20.1.1926 | ColumnnidL2CPPort8DMAC0180C200002ELocal | read-write | current | NID Series card Port 8 L2CP Mode 0180C200002E 0: Forward 1: Discard 2: Peer |
| 1.3.6.1.4.1.4756.20.500.20.1.1927 | ColumnnidL2CPPort8DMAC0180C200002FLocal | read-write | current | NID Series card Port 8 L2CP Mode 0180C200002F 0: Forward 1: Discard 1: Peer |
| 1.3.6.1.4.1.4756.20.500.20.1.1928 | ColumnnidFx1DDLocal | read-only | current | NID Series card fiber port Digital Diagnostic function: 0:No 1:Yes |
| 1.3.6.1.4.1.4756.20.500.20.1.1929 | ColumnnidFx1DDVendorLocal | read-only | current | NID Series card fiber port D/D information: Vendor name |
| 1.3.6.1.4.1.4756.20.500.20.1.1930 | ColumnnidFx1DDPartNoLocal | read-only | current | NID Series card fiber port D/D information: Vendor part number |
| 1.3.6.1.4.1.4756.20.500.20.1.1931 | ColumnnidFx1DDFiberTypeLocal | read-only | current | NID Series card fiber port D/D information: Fiber Type |
| 1.3.6.1.4.1.4756.20.500.20.1.1932 | ColumnnidFx1DDWaveLenLocal | read-only | current | NID Series card fiber port D/D information: Wave length |
| 1.3.6.1.4.1.4756.20.500.20.1.1933 | ColumnnidFx1DDWaveLen2Local | read-only | current | NID Series card fiber port D/D information: Wave length 2 |
| 1.3.6.1.4.1.4756.20.500.20.1.1934 | ColumnnidFx1DDLinkLenLocal | read-only | current | NID Series card fiber port D/D information: Link length |
| 1.3.6.1.4.1.4756.20.500.20.1.1935 | ColumnnidFx1DDLenUnitLocal | read-only | current | NID Series card fiber port D/D information: Length Unit |
| 1.3.6.1.4.1.4756.20.500.20.1.1936 | ColumnnidFx1DDStatusLocal | read-only | current | NID Series card fiber port D/D information: Status Support |
| 1.3.6.1.4.1.4756.20.500.20.1.1937 | ColumnnidFx1DDRxSensLocal | read-only | current | NID Series card fiber port D/D information: Rx Sensitivity |
| 1.3.6.1.4.1.4756.20.500.20.1.1938 | ColumnnidFx1DDTxPWRLocal | read-only | current | NID Series card fiber port D/D information: Tx power |
| 1.3.6.1.4.1.4756.20.500.20.1.1939 | ColumnnidFx1DDRxPWRLocal | read-only | current | NID Series card fiber port D/D information: Rx power |
| 1.3.6.1.4.1.4756.20.500.20.1.1940 | ColumnnidFx1DDTempLocal | read-only | current | NID Series card fiber port D/D information: Temperature in degree C |
| 1.3.6.1.4.1.4756.20.500.20.1.1941 | ColumnnidFx1DDPWRMarginLocal | read-only | current | NID Series card fiber port D/D information: Power margin |
| 1.3.6.1.4.1.4756.20.500.20.1.1942 | ColumnnidFx1DDPWRLossLocal | read-only | current | NID Series card fiber port D/D information: Power loss |
| 1.3.6.1.4.1.4756.20.500.20.1.1943 | ColumnnidFx2DDLocal | read-only | current | NID Series card fiber2 Digital Diagnostic function: 0:NO 1:Yes |
| 1.3.6.1.4.1.4756.20.500.20.1.1944 | ColumnnidFx2DDVendorLocal | read-only | current | NID Series card fiber2 D/D information: Vendor name |
| 1.3.6.1.4.1.4756.20.500.20.1.1945 | ColumnnidFx2DDPartNoLocal | read-only | current | NID Series card fiber2 D/D information: Vendor part number |
| 1.3.6.1.4.1.4756.20.500.20.1.1946 | ColumnnidFx2DDFiberTypeLocal | read-only | current | NID Series card fiber2 D/D information: Fiber Type |
| 1.3.6.1.4.1.4756.20.500.20.1.1947 | ColumnnidFx2DDWaveLenLocal | read-only | current | NID Series card fiber2 D/D information: Wave length 1 |
| 1.3.6.1.4.1.4756.20.500.20.1.1948 | ColumnnidFx2DDWaveLen2Local | read-only | current | NID Series card fiber2 D/D information: Wave length 2 |
| 1.3.6.1.4.1.4756.20.500.20.1.1949 | ColumnnidFx2DDLinkLenLocal | read-only | current | NID Series card fiber2 D/D information: Link length |
| 1.3.6.1.4.1.4756.20.500.20.1.1950 | ColumnnidFx2DDLenUnitLocal | read-only | current | NID Series card fiber2 D/D information: Length Unit |
| 1.3.6.1.4.1.4756.20.500.20.1.1951 | ColumnnidFx2DDStatusLocal | read-only | current | NID Series card fiber2 D/D information: Status Support |
| 1.3.6.1.4.1.4756.20.500.20.1.1952 | ColumnnidFx2DDRxSensLocal | read-only | current | NID Series card fiber2 D/D information: Rx Sensitivity |
| 1.3.6.1.4.1.4756.20.500.20.1.1953 | ColumnnidFx2DDTxPWRLocal | read-only | current | NID Series card fiber2 D/D information: Tx power |
| 1.3.6.1.4.1.4756.20.500.20.1.1954 | ColumnnidFx2DDRxPWRLocal | read-only | current | NID Series card fiber2 D/D information: Rx power |
| 1.3.6.1.4.1.4756.20.500.20.1.1955 | ColumnnidFx2DDTempLocal | read-only | current | NID Series card fiber2 D/D information: Temperature in degree C |
| 1.3.6.1.4.1.4756.20.500.20.1.1956 | ColumnnidFx2DDPWRMarginLocal | read-only | current | NID Series card fiber2 D/D information: Power margin |
| 1.3.6.1.4.1.4756.20.500.20.1.1957 | ColumnnidFx2DDPWRLossLocal | read-only | current | NID Series card fiber2 D/D information: Power loss |
| 1.3.6.1.4.1.4756.20.500.20.1.1958 | ColumnnidFx3DDLocal | read-only | current | NID Series card fiber3 Digital Diagnostic function: 0:NO 1:Yes |
| 1.3.6.1.4.1.4756.20.500.20.1.1959 | ColumnnidFx3DDVendorLocal | read-only | current | NID Series card fiber3 D/D information: Vendor name |
| 1.3.6.1.4.1.4756.20.500.20.1.1960 | ColumnnidFx3DDPartNoLocal | read-only | current | NID Series card fiber32 D/D information: Vendor part number |
| 1.3.6.1.4.1.4756.20.500.20.1.1961 | ColumnnidFx3DDFiberTypeLocal | read-only | current | NID Series card fiber3 D/D information: Fiber Type |
| 1.3.6.1.4.1.4756.20.500.20.1.1962 | ColumnnidFx3DDWaveLenLocal | read-only | current | NID Series card fiber3 D/D information: Wave length 1 |
| 1.3.6.1.4.1.4756.20.500.20.1.1963 | ColumnnidFx3DDWaveLen2Local | read-only | current | NID Series card fiber3 D/D information: Wave length 2 |
| 1.3.6.1.4.1.4756.20.500.20.1.1964 | ColumnnidFx3DDLinkLenLocal | read-only | current | NID Series card fiber3 D/D information: Link length |
| 1.3.6.1.4.1.4756.20.500.20.1.1965 | ColumnnidFx3DDLenUnitLocal | read-only | current | NID Series card fiber3 D/D information: Length Unit |
| 1.3.6.1.4.1.4756.20.500.20.1.1966 | ColumnnidFx3DDStatusLocal | read-only | current | NID Series card fiber3 D/D information: Status Support |
| 1.3.6.1.4.1.4756.20.500.20.1.1967 | ColumnnidFx3DDRxSensLocal | read-only | current | NID Series card fiber3 D/D information: Rx Sensitivity |
| 1.3.6.1.4.1.4756.20.500.20.1.1968 | ColumnnidFx3DDTxPWRLocal | read-only | current | NID Series card fiber3 D/D information: Tx power |
| 1.3.6.1.4.1.4756.20.500.20.1.1969 | ColumnnidFx3DDRxPWRLocal | read-only | current | NID Series card fiber3 D/D information: Rx power |
| 1.3.6.1.4.1.4756.20.500.20.1.1970 | ColumnnidFx3DDTempLocal | read-only | current | NID Series card fiber3 D/D information: Temperature in degree C |
| 1.3.6.1.4.1.4756.20.500.20.1.1971 | ColumnnidFx3DDPWRMarginLocal | read-only | current | NID Series card fiber3 D/D information: Power margin |
| 1.3.6.1.4.1.4756.20.500.20.1.1972 | ColumnnidFx3DDPWRLossLocal | read-only | current | NID Series card fiber3 D/D information: Power loss |
| 1.3.6.1.4.1.4756.20.500.20.1.1973 | ColumnnidFx4DDLocal | read-only | current | NID Series card fiber4 Digital Diagnostic function: 0:NO 1:Yes |
| 1.3.6.1.4.1.4756.20.500.20.1.1974 | ColumnnidFx4DDVendorLocal | read-only | current | NID Series card fiber4 D/D information: Vendor name |
| 1.3.6.1.4.1.4756.20.500.20.1.1975 | ColumnnidFx4DDPartNoLocal | read-only | current | NID Series card fiber4 D/D information: Vendor part number |
| 1.3.6.1.4.1.4756.20.500.20.1.1976 | ColumnnidFx4DDFiberTypeLocal | read-only | current | NID Series card fiber4 D/D information: Fiber Type |
| 1.3.6.1.4.1.4756.20.500.20.1.1977 | ColumnnidFx4DDWaveLenLocal | read-only | current | NID Series card fiber4 D/D information: Wave length 1 |
| 1.3.6.1.4.1.4756.20.500.20.1.1978 | ColumnnidFx4DDWaveLen2Local | read-only | current | NID Series card fiber4 D/D information: Wave length 2 |
| 1.3.6.1.4.1.4756.20.500.20.1.1979 | ColumnnidFx4DDLinkLenLocal | read-only | current | NID Series card fiber4 D/D information: Link length |
| 1.3.6.1.4.1.4756.20.500.20.1.1980 | ColumnnidFx4DDLenUnitLocal | read-only | current | NID Series card fiber4 D/D information: Length Unit |
| 1.3.6.1.4.1.4756.20.500.20.1.1981 | ColumnnidFx4DDStatusLocal | read-only | current | NID Series card fiber4 D/D information: Status Support |
| 1.3.6.1.4.1.4756.20.500.20.1.1982 | ColumnnidFx4DDRxSensLocal | read-only | current | NID Series card fiber4 D/D information: Rx Sensitivity |
| 1.3.6.1.4.1.4756.20.500.20.1.1983 | ColumnnidFx4DDTxPWRLocal | read-only | current | NID Series card fiber4 D/D information: Tx power |
| 1.3.6.1.4.1.4756.20.500.20.1.1984 | ColumnnidFx4DDRxPWRLocal | read-only | current | NID Series card fiber4 D/D information: Rx power |
| 1.3.6.1.4.1.4756.20.500.20.1.1985 | ColumnnidFx4DDTempLocal | read-only | current | NID Series card fiber4 D/D information: Temperature in degree C |
| 1.3.6.1.4.1.4756.20.500.20.1.1986 | ColumnnidFx4DDPWRMarginLocal | read-only | current | NID Series card fiber4 D/D information: Power margin |
| 1.3.6.1.4.1.4756.20.500.20.1.1987 | ColumnnidFx4DDPWRLossLocal | read-only | current | NID Series card fiber4 D/D information: Power loss |
| 1.3.6.1.4.1.4756.20.500.20.1.1988 | ColumnnidDeviceActiveLocal | read-write | current | NID Series card u-Ring device active 0: Disable 1: Enable |
| 1.3.6.1.4.1.4756.20.500.20.1.1989 | ColumnnidSaveStartupCongLocal | read-write | current | NID Series card save start-up config 0: OFF 1: Action |
| 1.3.6.1.4.1.4756.20.500.20.1.1990 | ColumnnidPortResetLocal | read-write | current | NID Series card port reset 0: OFF 1: Action |
| 1.3.6.1.4.1.4756.20.500.20.1.1991 | ColumnnidSetDefaultLocal | read-write | current | NID Series card set to default config 0: OFF 1: Action |
| 1.3.6.1.4.1.4756.20.500.20.1.1992 | ColumnnidSetDefault2Local | read-write | current | NID Series card set to default config (Without OAM) 0: OFF 1: Action |
| 1.3.6.1.4.1.4756.20.500.20.1.1993 | ColumnnidClearPortCounterLocal | read-write | current | NID Series card clear port counter: 0: Off 1: Action |
| 1.3.6.1.4.1.4756.20.500.20.1.1994 | ColumnnidClearOAMCounterLocal | read-write | current | NID Series card Clear OAM Counter: 0: Off 1: Action |
| 1.3.6.1.4.1.4756.20.500.20.1.1995 | ColumnnidSTPStatisticsPortClearCounterLocal | read-write | current | NID Series card STP Port Statistics: Clear Counters 0: OFff 1: Action |
| 1.3.6.1.4.1.4756.20.500.20.1.1996 | ColumnnidAlarmLocal | read-only | current | NID Series card Alarm led status: 0: Off 1: On |
| 1.3.6.1.4.1.4756.20.500.20.1.1997 | ColumnnidTest1Local | read-only | current | NID Series card Test1 led status: 0: Off 1: On |
| 1.3.6.1.4.1.4756.20.500.20.1.1998 | ColumnnidTest2Local | read-only | current | NID Series card Test2 led status: 0: Off 1: On |
| 1.3.6.1.4.1.4756.20.501 | NodenidRemoteACards | |||
| 1.3.6.1.4.1.4756.20.501.20 | TablenidRemoteATable | not-accessible | current | A list of RemoteA FRM220-MSW404/MSW404S card entries. The number of entries is f16G3R-No-L. |
| 1.3.6.1.4.1.4756.20.501.20.1 | RownidRemoteAEntry | not-accessible | current | An entry containing management information applicable to a particular RemoteA FRM220-MSW404/MSW404S card. |
| 1.3.6.1.4.1.4756.20.501.20.1.1 | ColumnnidChassisIndexRemoteA | read-only | current | A unique value for each RemoteA card. It is the chassis location number. |
| 1.3.6.1.4.1.4756.20.501.20.1.2 | ColumnnidSlotIndexRemoteA | read-only | current | A unique value for each RemoteA card. It is the slot location number. |
| 1.3.6.1.4.1.4756.20.501.20.1.3 | ColumnnidCardHWVerRemoteA | read-only | current | RemoteA NID card hardware version x.xxx |
| 1.3.6.1.4.1.4756.20.501.20.1.4 | ColumnnidCardFWVerRemoteA | read-only | current | RemoteA NID card firmware version x.xxx |
| 1.3.6.1.4.1.4756.20.501.20.1.5 | ColumnnidCardCPLDVerRemoteA | read-only | current | RemoteA NID card CPLD version x.xxx |
| 1.3.6.1.4.1.4756.20.501.20.1.6 | ColumnnidCardFPGAVerRemoteA | read-only | current | RemoteA NID card FPGA version x.xxx |
| 1.3.6.1.4.1.4756.20.501.20.1.7 | ColumnnidModelRemoteA | read-only | current | Card Type: 0:MSW404 1:MSW404S |
| 1.3.6.1.4.1.4756.20.501.20.1.8 | ColumnnidDNSServerTypeRemoteA | read-write | current | NID Series card IP Configuration: This setting controls the DNS name resolution done by the switch. The following modes are supported: 1:From any DHCP interfac… |
| 1.3.6.1.4.1.4756.20.501.20.1.9 | ColumnnidDNSServerSettingRemoteA | read-write | current | NID Series card IP Configuration: If iDNSServerType setting '3:Configured',this value must setting IP address format as below: Dotted Decimal Notation refers t… |
| 1.3.6.1.4.1.4756.20.501.20.1.10 | ColumnnidDNSproxyRemoteA | read-write | current | NID Series card IP Configuration: When DNS proxy is enabled, system will relay DNS requests to the currently configured DNS server, and reply as a DNS resolver… |
| 1.3.6.1.4.1.4756.20.501.20.1.11 | ColumnnidAddIPV4InterfaceRemoteA | read-write | current | NID Series card IP Interfaces: Add a new IP VLAN Interface: Syntax: [<Interface>] [<vlan_list>] [<IPV4_Addr>] [<IPV4_MASK>] Interface : 1~4 |
| 1.3.6.1.4.1.4756.20.501.20.1.12 | ColumnnidDeleteInterfaceRemoteA | read-write | current | NID Series card IP Interfaces: Delete a IPv4/v6 VLAN Interface: Syntax: [<Interface>] Interface: 1~4 |
| 1.3.6.1.4.1.4756.20.501.20.1.13 | ColumnnidIPInterface1VLANRemoteA | read-only | current | NID Series card IP Interfaces: The VLAN associated with the IP interface. Only ports in this VLAN will be able to access the IP interface. This field is only a… |
| 1.3.6.1.4.1.4756.20.501.20.1.14 | ColumnnidIPInterface1DHCPRemoteA | read-write | current | NID Series card IP Interfaces: DHCP |
| 1.3.6.1.4.1.4756.20.501.20.1.15 | ColumnnidIPInterface1FallbackRemoteA | read-write | current | NID Series card IP Interfaces: Fallback |
| 1.3.6.1.4.1.4756.20.501.20.1.16 | ColumnnidIPInterface1IPV4AddressRemoteA | read-only | current | NID Series card IP Interfaces: IPV4 Address |
| 1.3.6.1.4.1.4756.20.501.20.1.17 | ColumnnidIPInterface1IPV4MASKLenRemoteA | read-only | current | NID Series card IP Interfaces: IPV4 MASK Length |
| 1.3.6.1.4.1.4756.20.501.20.1.18 | ColumnnidIPInterface2VLANRemoteA | read-only | current | NID Series card IP Interfaces: The VLAN associated with the IP interface. Only ports in this VLAN will be able to access the IP interface. This field is only a… |
| 1.3.6.1.4.1.4756.20.501.20.1.19 | ColumnnidIPInterface2DHCPRemoteA | read-write | current | NID Series card IP Interfaces: DHCP |
| 1.3.6.1.4.1.4756.20.501.20.1.20 | ColumnnidIPInterface2FallbackRemoteA | read-write | current | NID Series card IP Interfaces: Fallback |
| 1.3.6.1.4.1.4756.20.501.20.1.21 | ColumnnidIPInterface2IPV4AddressRemoteA | read-only | current | NID Series card IP Interfaces: IPV4 Address |
| 1.3.6.1.4.1.4756.20.501.20.1.22 | ColumnnidIPInterface2IPV4MASKLenRemoteA | read-only | current | NID Series card IP Interfaces: IPV4 MASK Length |
| 1.3.6.1.4.1.4756.20.501.20.1.23 | ColumnnidIPInterface3VLANRemoteA | read-only | current | NID Series card IP Interfaces: The VLAN associated with the IP interface. Only ports in this VLAN will be able to access the IP interface. This field is only a… |
| 1.3.6.1.4.1.4756.20.501.20.1.24 | ColumnnidIPInterface3DHCPRemoteA | read-write | current | NID Series card IP Interfaces: DHCP |
| 1.3.6.1.4.1.4756.20.501.20.1.25 | ColumnnidIPInterface3FallbackRemoteA | read-write | current | NID Series card IP Interfaces: Fallback |
| 1.3.6.1.4.1.4756.20.501.20.1.26 | ColumnnidIPInterface3IPV4AddressRemoteA | read-only | current | NID Series card IP Interfaces: IPV4 Address |
| 1.3.6.1.4.1.4756.20.501.20.1.27 | ColumnnidIPInterface3IPV4MASKLenRemoteA | read-only | current | NID Series card IP Interfaces: IPV4 MASK Length |
| 1.3.6.1.4.1.4756.20.501.20.1.28 | ColumnnidIPInterface4VLANRemoteA | read-only | current | NID Series card IP Interfaces: The VLAN associated with the IP interface. Only ports in this VLAN will be able to access the IP interface. This field is only a… |
| 1.3.6.1.4.1.4756.20.501.20.1.29 | ColumnnidIPInterface4DHCPRemoteA | read-write | current | NID Series card IP Interfaces: DHCP |
| 1.3.6.1.4.1.4756.20.501.20.1.30 | ColumnnidIPInterface4FallbackRemoteA | read-write | current | NID Series card IP Interfaces: Fallback |
| 1.3.6.1.4.1.4756.20.501.20.1.31 | ColumnnidIPInterface4IPV4AddressRemoteA | read-only | current | NID Series card IP Interfaces: IPV4 Address |
| 1.3.6.1.4.1.4756.20.501.20.1.32 | ColumnnidIPInterface4IPV4MASKLenRemoteA | read-only | current | NID Series card IP Interfaces: IPV4 MASK Length |
| 1.3.6.1.4.1.4756.20.501.20.1.33 | ColumnnidAddIPV6InterfaceRemoteA | read-write | current | NID Series card IP Interfaces: Add a new IPv6 VLAN Interface: Syntax: [<Interface>] [<vlan_list>] [<IPV4_Addr>] [<IPV4_MASK>] Interface : 1~4 |
| 1.3.6.1.4.1.4756.20.501.20.1.34 | ColumnnidIPInterface1IPV6AddressRemoteA | read-only | current | NID Series card IP Interfaces: IPV6 Address |
| 1.3.6.1.4.1.4756.20.501.20.1.35 | ColumnnidIPInterface1IPV6MASKLenRemoteA | read-only | current | NID Series card IP Interfaces: IPV6 MASK Length |
| 1.3.6.1.4.1.4756.20.501.20.1.36 | ColumnnidIPInterface2IPV6AddressRemoteA | read-only | current | NID Series card IP Interfaces: IPV6 Address |
| 1.3.6.1.4.1.4756.20.501.20.1.37 | ColumnnidIPInterface2IPV6MASKLenRemoteA | read-only | current | NID Series card IP Interfaces: IPV6 MASK Length |
| 1.3.6.1.4.1.4756.20.501.20.1.38 | ColumnnidIPInterface3IPV6AddressRemoteA | read-only | current | NID Series card IP Interfaces: IPV6 Address |
| 1.3.6.1.4.1.4756.20.501.20.1.39 | ColumnnidIPInterface3IPV6MASKLenRemoteA | read-only | current | NID Series card IP Interfaces: IPV6 MASK Length |
| 1.3.6.1.4.1.4756.20.501.20.1.40 | ColumnnidIPInterface4IPV6AddressRemoteA | read-only | current | NID Series card IP Interfaces: IPV6 Address |
| 1.3.6.1.4.1.4756.20.501.20.1.41 | ColumnnidIPInterface4IPV6MASKLenRemoteA | read-only | current | NID Series card IP Interfaces: IPV6 MASK Length |
| 1.3.6.1.4.1.4756.20.501.20.1.42 | ColumnnidPort1LinkstsRemoteA | read-only | current | NID Series card Port1 link status: 0:Link down 1:Link up |
| 1.3.6.1.4.1.4756.20.501.20.1.43 | ColumnnidPort1SpeedstsRemoteA | read-only | current | NID Series card Port1 speed status 10Base-T 100Base-Tx 1000Base-Tx 2.5G |
| 1.3.6.1.4.1.4756.20.501.20.1.44 | ColumnnidPort1DuplexstsRemoteA | read-only | current | NID Series card Port1 duplex status 0: Half 1: Full |
| 1.3.6.1.4.1.4756.20.501.20.1.45 | ColumnnidPort1RxPausestsRemoteA | read-only | current | NID Series card Port1 rx pause status 0: No 1: Yes |
| 1.3.6.1.4.1.4756.20.501.20.1.46 | ColumnnidPort1TxPausestsRemoteA | read-only | current | NID Series card Port1 tx pause status 0: No 1: Yes |
| 1.3.6.1.4.1.4756.20.501.20.1.47 | ColumnnidPort2LinkstsRemoteA | read-only | current | NID Series card Port2 link status: 0:Link down 1:Link up |
| 1.3.6.1.4.1.4756.20.501.20.1.48 | ColumnnidPort2SpeedstsRemoteA | read-only | current | NID Series card Port2 speed status 10Base-T 100Base-Tx 1000Base-Tx 2.5G |
| 1.3.6.1.4.1.4756.20.501.20.1.49 | ColumnnidPort2DuplexstsRemoteA | read-only | current | NID Series card Port2 duplex status 0: Half 1: Full |
| 1.3.6.1.4.1.4756.20.501.20.1.50 | ColumnnidPort2RxPausestsRemoteA | read-only | current | NID Series card Port2 rx pause status 0: No 1: Yes |
| 1.3.6.1.4.1.4756.20.501.20.1.51 | ColumnnidPort2TxPausestsRemoteA | read-only | current | NID Series card Port2 tx pause status 0: No 1: Yes |
| 1.3.6.1.4.1.4756.20.501.20.1.52 | ColumnnidPort3LinkstsRemoteA | read-only | current | NID Series card Port3 link status: 0:Link down 1:Link up |
| 1.3.6.1.4.1.4756.20.501.20.1.53 | ColumnnidPort3SpeedstsRemoteA | read-only | current | NID Series card Port3 speed status 10Base-T 100Base-Tx 1000Base-Tx |
| 1.3.6.1.4.1.4756.20.501.20.1.54 | ColumnnidPort3DuplexstsRemoteA | read-only | current | NID Series card Port3 duplex status 0: Half 1: Full |
| 1.3.6.1.4.1.4756.20.501.20.1.55 | ColumnnidPort3RxPausestsRemoteA | read-only | current | NID Series card Port3 rx pause status 0: No 1: Yes |
| 1.3.6.1.4.1.4756.20.501.20.1.56 | ColumnnidPort3TxPausestsRemoteA | read-only | current | NID Series card Port3 tx pause status 0: No 1: Yes |
| 1.3.6.1.4.1.4756.20.501.20.1.57 | ColumnnidPort4LinkstsRemoteA | read-only | current | NID Series card Port4 link status: 0:Link down 1:Link up |
| 1.3.6.1.4.1.4756.20.501.20.1.58 | ColumnnidPort4SpeedstsRemoteA | read-only | current | NID Series card Port4 speed status 10Base-T 100Base-Tx 1000Base-Tx |
| 1.3.6.1.4.1.4756.20.501.20.1.59 | ColumnnidPort4DuplexstsRemoteA | read-only | current | NID Series card Port4 duplex status 0: Half 1: Full |
| 1.3.6.1.4.1.4756.20.501.20.1.60 | ColumnnidPort4RxPausestsRemoteA | read-only | current | NID Series card Port4 rx pause status 0: No 1: Yes |
| 1.3.6.1.4.1.4756.20.501.20.1.61 | ColumnnidPort4TxPausestsRemoteA | read-only | current | NID Series card Port4 tx pause status 0: No 1: Yes |
| 1.3.6.1.4.1.4756.20.501.20.1.62 | ColumnnidPort5LinkstsRemoteA | read-only | current | NID Series card Port5 link status: 0:Link down 1:Link up |
| 1.3.6.1.4.1.4756.20.501.20.1.63 | ColumnnidPort5SpeedstsRemoteA | read-only | current | NID Series card Port5 speed status 10Base-T 100Base-Tx 1000Base-Tx |
| 1.3.6.1.4.1.4756.20.501.20.1.64 | ColumnnidPort5DuplexstsRemoteA | read-only | current | NID Series card Port5 duplex status 0: Half 1: Full |
| 1.3.6.1.4.1.4756.20.501.20.1.65 | ColumnnidPort5RxPausestsRemoteA | read-only | current | NID Series card Port5 rx pause status 0: No 1: Yes |
| 1.3.6.1.4.1.4756.20.501.20.1.66 | ColumnnidPort5TxPausestsRemoteA | read-only | current | NID Series card Port5 tx pause status 0: No 1: Yes |
| 1.3.6.1.4.1.4756.20.501.20.1.67 | ColumnnidPort6LinkstsRemoteA | read-only | current | NID Series card Port6 link status: 0:Link down 1:Link up |
| 1.3.6.1.4.1.4756.20.501.20.1.68 | ColumnnidPort6SpeedstsRemoteA | read-only | current | NID Series card Port6 speed status 10Base-T 100Base-Tx 1000Base-Tx |
| 1.3.6.1.4.1.4756.20.501.20.1.69 | ColumnnidPort6DuplexstsRemoteA | read-only | current | NID Series card Port6 duplex status 0: Half 1: Full |
| 1.3.6.1.4.1.4756.20.501.20.1.70 | ColumnnidPort6RxPausestsRemoteA | read-only | current | NID Series card Port6 rx pause status 0: No 1: Yes |
| 1.3.6.1.4.1.4756.20.501.20.1.71 | ColumnnidPort6TxPausestsRemoteA | read-only | current | NID Series card Port6 tx pause status 0: No 1: Yes |
| 1.3.6.1.4.1.4756.20.501.20.1.72 | ColumnnidPort7LinkstsRemoteA | read-only | current | NID Series card Port7 link status: 0:Link down 1:Link up |
| 1.3.6.1.4.1.4756.20.501.20.1.73 | ColumnnidPort7SpeedstsRemoteA | read-only | current | NID Series card Port7 speed status 10Base-T 100Base-Tx 1000Base-Tx |
| 1.3.6.1.4.1.4756.20.501.20.1.74 | ColumnnidPort7DuplexstsRemoteA | read-only | current | NID Series card Port7 duplex status 0: Half 1: Full |
| 1.3.6.1.4.1.4756.20.501.20.1.75 | ColumnnidPort7RxPausestsRemoteA | read-only | current | NID Series card Port7 rx pause status 0: No 1: Yes |
| 1.3.6.1.4.1.4756.20.501.20.1.76 | ColumnnidPort7TxPausestsRemoteA | read-only | current | NID Series card Port7 tx pause status 0: No 1: Yes |
| 1.3.6.1.4.1.4756.20.501.20.1.77 | ColumnnidPort8LinkstsRemoteA | read-only | current | NID Series card Port8 link status: 0:Link down 1:Link up |
| 1.3.6.1.4.1.4756.20.501.20.1.78 | ColumnnidPort8SpeedstsRemoteA | read-only | current | NID Series card Port8 speed status 10Base-T 100Base-Tx 1000Base-Tx |
| 1.3.6.1.4.1.4756.20.501.20.1.79 | ColumnnidPort8DuplexstsRemoteA | read-only | current | NID Series card Port8 duplex status 0: Half 1: Full |
| 1.3.6.1.4.1.4756.20.501.20.1.80 | ColumnnidPort8RxPausestsRemoteA | read-only | current | NID Series card Port8 rx pause status 0: No 1: Yes |
| 1.3.6.1.4.1.4756.20.501.20.1.81 | ColumnnidPort8TxPausestsRemoteA | read-only | current | NID Series card Port8 tx pause status 0: No 1: Yes |
| 1.3.6.1.4.1.4756.20.501.20.1.82 | ColumnnidPort1SpeedConfRemoteA | read-write | current | NID Series card Port1 speed config 0: disable 1: auto 2: 100M FDX 3: 1G FDX 4: 2.5G FDX |
| 1.3.6.1.4.1.4756.20.501.20.1.83 | ColumnnidPort1flowConrolRemoteA | read-write | current | NID Series card Port1 flow control config 0: no 1: yes |
| 1.3.6.1.4.1.4756.20.501.20.1.84 | ColumnnidPort1MaxFrameRemoteA | read-write | current | NID Series card Port1 max frame config |
| 1.3.6.1.4.1.4756.20.501.20.1.85 | ColumnnidPort1ALSRemoteA | read-write | current | NID Series card Port1 auto laser shutdown: 0: Disable 1: Enable |
| 1.3.6.1.4.1.4756.20.501.20.1.86 | ColumnnidPort2SpeedConfRemoteA | read-write | current | NID Series card Port2 speed config 0: disable 1: auto 2: 100M FDX 3: 1G FDX 4: 2.5G FDX |
| 1.3.6.1.4.1.4756.20.501.20.1.87 | ColumnnidPort2flowConrolRemoteA | read-write | current | NID Series card Port2 flow control config 0: no 1: yes |
| 1.3.6.1.4.1.4756.20.501.20.1.88 | ColumnnidPort2MaxFrameRemoteA | read-write | current | NID Series card Port2 max frame config |
| 1.3.6.1.4.1.4756.20.501.20.1.89 | ColumnnidPort2ALSRemoteA | read-write | current | NID Series card Port2 auto laser shutdown: 0: Disable 1: Enable |
| 1.3.6.1.4.1.4756.20.501.20.1.90 | ColumnnidPort3SpeedConfRemoteA | read-write | current | NID Series card Port3 speed config 0: disable 1: auto 2: 100M FDX 3: 1G FDX |
| 1.3.6.1.4.1.4756.20.501.20.1.91 | ColumnnidPort3flowConrolRemoteA | read-write | current | NID Series card Port3 flow control config 0: no 1: yes |
| 1.3.6.1.4.1.4756.20.501.20.1.92 | ColumnnidPort3MaxFrameRemoteA | read-write | current | NID Series card Port3 max frame config |
| 1.3.6.1.4.1.4756.20.501.20.1.93 | ColumnnidPort3ALSRemoteA | read-write | current | NID Series card Port3 auto laser shutdown: 0: Disable 1: Enable |
| 1.3.6.1.4.1.4756.20.501.20.1.94 | ColumnnidPort4SpeedConfRemoteA | read-write | current | NID Series card Port4 speed config 0: disable 1: auto 2: 100M FDX 3: 1G FDX |
| 1.3.6.1.4.1.4756.20.501.20.1.95 | ColumnnidPort4flowConrolRemoteA | read-write | current | NID Series card Port4 flow control config 0: no 1: yes |
| 1.3.6.1.4.1.4756.20.501.20.1.96 | ColumnnidPort4MaxFrameRemoteA | read-write | current | NID Series card Port4 max frame config |
| 1.3.6.1.4.1.4756.20.501.20.1.97 | ColumnnidPort4ALSRemoteA | read-write | current | NID Series card Port4 auto laser shutdown: 0: Disable 1: Enable |
| 1.3.6.1.4.1.4756.20.501.20.1.98 | ColumnnidPort5SpeedConfRemoteA | read-write | current | NID Series card Port5 speed config 0: disable 1: auto 2: 10M HDX 3: 10M FDX 4: 100M HDX 5: 100M FDX 6: 1G FDX |
| 1.3.6.1.4.1.4756.20.501.20.1.99 | ColumnnidPort5flowConrolRemoteA | read-write | current | NID Series card Port5 flow control config 0: no 1: yes |
| 1.3.6.1.4.1.4756.20.501.20.1.100 | ColumnnidPort5MaxFrameRemoteA | read-write | current | NID Series card Port5 max frame config |
| 1.3.6.1.4.1.4756.20.501.20.1.101 | ColumnnidPort5CollisionModeRemoteA | read-write | current | NID Series card Port5 collision mode config. 0: Discard 1: Restart |
| 1.3.6.1.4.1.4756.20.501.20.1.102 | ColumnnidPort6SpeedConfRemoteA | read-write | current | NID Series card Port6 speed config 0: disable 1: auto 2: 10M HDX 3: 10M FDX 4: 100M HDX 5: 100M FDX 6: 1G FDX |
| 1.3.6.1.4.1.4756.20.501.20.1.103 | ColumnnidPort6flowConrolRemoteA | read-write | current | NID Series card Port6 flow control config 0: no 1: yes |
| 1.3.6.1.4.1.4756.20.501.20.1.104 | ColumnnidPort6MaxFrameRemoteA | read-write | current | NID Series card Port6 max frame config |
| 1.3.6.1.4.1.4756.20.501.20.1.105 | ColumnnidPort6CollisionModeRemoteA | read-write | current | NID Series card Port6 collision mode config. 0: Discard 1: Restart |
| 1.3.6.1.4.1.4756.20.501.20.1.106 | ColumnnidPort7SpeedConfRemoteA | read-write | current | NID Series card Port7 speed config 0: disable 1: auto 2: 10M HDX 3: 10M FDX 4: 100M HDX 5: 100M FDX 6: 1G FDX |
| 1.3.6.1.4.1.4756.20.501.20.1.107 | ColumnnidPort7flowConrolRemoteA | read-write | current | NID Series card Port7 flow control config 0: no 1: yes |
| 1.3.6.1.4.1.4756.20.501.20.1.108 | ColumnnidPort7MaxFrameRemoteA | read-write | current | NID Series card Port7 max frame config |
| 1.3.6.1.4.1.4756.20.501.20.1.109 | ColumnnidPort7CollisionModeRemoteA | read-write | current | NID Series card Port7 collision mode config. 0: Discard 1: Restart |
| 1.3.6.1.4.1.4756.20.501.20.1.110 | ColumnnidPort8SpeedConfRemoteA | read-write | current | NID Series card Port8 speed config 0: disable 1: auto 2: 10M HDX 3: 10M FDX 4: 100M HDX 5: 100M FDX 6: 1G FDX |
| 1.3.6.1.4.1.4756.20.501.20.1.111 | ColumnnidPort8flowConrolRemoteA | read-write | current | NID Series card Port8 flow control config 0: no 1: yes |
| 1.3.6.1.4.1.4756.20.501.20.1.112 | ColumnnidPort8MaxFrameRemoteA | read-write | current | NID Series card Port8 max frame config |
| 1.3.6.1.4.1.4756.20.501.20.1.113 | ColumnnidPort8CollisionModeRemoteA | read-write | current | NID Series card Port8 collision mode config. 0: Discard 1: Restart |
| 1.3.6.1.4.1.4756.20.501.20.1.114 | ColumnnidPort1LLFLogicRemoteA | read-write | current | NID Series card Port1 link loss forwarding - Logic 0: AND 1: OR |
| 1.3.6.1.4.1.4756.20.501.20.1.115 | ColumnnidPort1LLFLogicPort2RemoteA | read-write | current | NID Series card Port1 link loss forwarding - Link/Rx Loss Port2 0: NO 1: YES |
| 1.3.6.1.4.1.4756.20.501.20.1.116 | ColumnnidPort1LLFLogicPort3RemoteA | read-write | current | NID Series card Port1 link loss forwarding - Link/Rx Loss Port3 0: NO 1: YES |
| 1.3.6.1.4.1.4756.20.501.20.1.117 | ColumnnidPort1LLFLogicPort4RemoteA | read-write | current | NID Series card Port1 link loss forwarding - Link/Rx Loss Port4 0: NO 1: YES |
| 1.3.6.1.4.1.4756.20.501.20.1.118 | ColumnnidPort1LLFLogicPort5RemoteA | read-write | current | NID Series card Port1 link loss forwarding - Link/Rx Loss Port5 0: NO 1: YES |
| 1.3.6.1.4.1.4756.20.501.20.1.119 | ColumnnidPort1LLFLogicPort6RemoteA | read-write | current | NID Series card Port1 link loss forwarding - Link/Rx Loss Port6 0: NO 1: YES |
| 1.3.6.1.4.1.4756.20.501.20.1.120 | ColumnnidPort1LLFLogicPort7RemoteA | read-write | current | NID Series card Port1 link loss forwarding - Link/Rx Loss Port7 0: NO 1: YES |
| 1.3.6.1.4.1.4756.20.501.20.1.121 | ColumnnidPort1LLFLogicPort8RemoteA | read-write | current | NID Series card Port1 link loss forwarding - Link/Rx Loss Port8 0: NO 1: YES |
| 1.3.6.1.4.1.4756.20.501.20.1.122 | ColumnnidPort2LLFLogicRemoteA | read-write | current | NID Series card Port2 link loss forwarding - Logic 0: AND 1: OR |
| 1.3.6.1.4.1.4756.20.501.20.1.123 | ColumnnidPort2LLFLogicPort1RemoteA | read-write | current | NID Series card Port2 link loss forwarding - Link/Rx Loss Port1 0: NO 1: YES |
| 1.3.6.1.4.1.4756.20.501.20.1.124 | ColumnnidPort2LLFLogicPort3RemoteA | read-write | current | NID Series card Port2 link loss forwarding - Link/Rx Loss Port3 0: NO 1: YES |
| 1.3.6.1.4.1.4756.20.501.20.1.125 | ColumnnidPort2LLFLogicPort4RemoteA | read-write | current | NID Series card Port2 link loss forwarding - Link/Rx Loss Port4 0: NO 1: YES |
| 1.3.6.1.4.1.4756.20.501.20.1.126 | ColumnnidPort2LLFLogicPort5RemoteA | read-write | current | NID Series card Port2 link loss forwarding - Link/Rx Loss Port54 0: NO 1: YES |
| 1.3.6.1.4.1.4756.20.501.20.1.127 | ColumnnidPort2LLFLogicPort6RemoteA | read-write | current | NID Series card Port2 link loss forwarding - Link/Rx Loss Port6 0: NO 1: YES |
| 1.3.6.1.4.1.4756.20.501.20.1.128 | ColumnnidPort2LLFLogicPort7RemoteA | read-write | current | NID Series card Port2 link loss forwarding - Link/Rx Loss Port7 0: NO 1: YES |
| 1.3.6.1.4.1.4756.20.501.20.1.129 | ColumnnidPort2LLFLogicPort8RemoteA | read-write | current | NID Series card Port2 link loss forwarding - Link/Rx Loss Port8 0: NO 1: YES |
| 1.3.6.1.4.1.4756.20.501.20.1.130 | ColumnnidPort3LLFLogicRemoteA | read-write | current | NID Series card Port1 link loss forwarding - Logic 0: AND 1: OR |
| 1.3.6.1.4.1.4756.20.501.20.1.131 | ColumnnidPort3LLFLogicPort1RemoteA | read-write | current | NID Series card Port3 link loss forwarding - Link/Rx Loss Port1 0: NO 1: YES |
| 1.3.6.1.4.1.4756.20.501.20.1.132 | ColumnnidPort3LLFLogicPort2RemoteA | read-write | current | NID Series card Port3 link loss forwarding - Link/Rx Loss Port2 0: NO 1: YES |
| 1.3.6.1.4.1.4756.20.501.20.1.133 | ColumnnidPort3LLFLogicPort4RemoteA | read-write | current | NID Series card Port3 link loss forwarding - Link/Rx Loss Port4 0: NO 1: YES |
| 1.3.6.1.4.1.4756.20.501.20.1.134 | ColumnnidPort3LLFLogicPort5RemoteA | read-write | current | NID Series card Port3 link loss forwarding - Link/Rx Loss Port5 0: NO 1: YES |
| 1.3.6.1.4.1.4756.20.501.20.1.135 | ColumnnidPort3LLFLogicPort6RemoteA | read-write | current | NID Series card Port3 link loss forwarding - Link/Rx Loss Port6 0: NO 1: YES |
| 1.3.6.1.4.1.4756.20.501.20.1.136 | ColumnnidPort3LLFLogicPort7RemoteA | read-write | current | NID Series card Port3 link loss forwarding - Link/Rx Loss Port7 0: NO 1: YES |
| 1.3.6.1.4.1.4756.20.501.20.1.137 | ColumnnidPort3LLFLogicPort8RemoteA | read-write | current | NID Series card Port3 link loss forwarding - Link/Rx Loss Port8 0: NO 1: YES |
| 1.3.6.1.4.1.4756.20.501.20.1.138 | ColumnnidPort4LLFLogicRemoteA | read-write | current | NID Series card Port4 link loss forwarding - Logic 0: AND 1: OR |
| 1.3.6.1.4.1.4756.20.501.20.1.139 | ColumnnidPort4LLFLogicPort1RemoteA | read-write | current | NID Series card Port4 link loss forwarding - Link/Rx Loss Port1 0: NO 1: YES |
| 1.3.6.1.4.1.4756.20.501.20.1.140 | ColumnnidPort4LLFLogicPort2RemoteA | read-write | current | NID Series card Port4 link loss forwarding - Link/Rx Loss Port2 0: NO 1: YES |
| 1.3.6.1.4.1.4756.20.501.20.1.141 | ColumnnidPort4LLFLogicPort3RemoteA | read-write | current | NID Series card Port4 link loss forwarding - Link/Rx Loss Port3 0: NO 1: YES |
| 1.3.6.1.4.1.4756.20.501.20.1.142 | ColumnnidPort4LLFLogicPort5RemoteA | read-write | current | NID Series card Port4 link loss forwarding - Link/Rx Loss Port5 0: NO 1: YES |
| 1.3.6.1.4.1.4756.20.501.20.1.143 | ColumnnidPort4LLFLogicPort6RemoteA | read-write | current | NID Series card Port4 link loss forwarding - Link/Rx Loss Port6 0: NO 1: YES |
| 1.3.6.1.4.1.4756.20.501.20.1.144 | ColumnnidPort4LLFLogicPort7RemoteA | read-write | current | NID Series card Port4 link loss forwarding - Link/Rx Loss Port7 0: NO 1: YES |
| 1.3.6.1.4.1.4756.20.501.20.1.145 | ColumnnidPort4LLFLogicPort8RemoteA | read-write | current | NID Series card Port4 link loss forwarding - Link/Rx Loss Port8 0: NO 1: YES |
| 1.3.6.1.4.1.4756.20.501.20.1.146 | ColumnnidPort5LLFLogicRemoteA | read-write | current | NID Series card Port5 link loss forwarding - Logic 0: AND 1: OR |
| 1.3.6.1.4.1.4756.20.501.20.1.147 | ColumnnidPort5LLFLogicPort1RemoteA | read-write | current | NID Series card Port5 link loss forwarding - Link/Rx Loss Port1 0: NO 1: YES |
| 1.3.6.1.4.1.4756.20.501.20.1.148 | ColumnnidPort5LLFLogicPort2RemoteA | read-write | current | NID Series card Port5 link loss forwarding - Link/Rx Loss Port2 0: NO 1: YES |
| 1.3.6.1.4.1.4756.20.501.20.1.149 | ColumnnidPort5LLFLogicPort3RemoteA | read-write | current | NID Series card Port5 link loss forwarding - Link/Rx Loss Port3 0: NO 1: YES |
| 1.3.6.1.4.1.4756.20.501.20.1.150 | ColumnnidPort5LLFLogicPort4RemoteA | read-write | current | NID Series card Port5 link loss forwarding - Link/Rx Loss Port4 0: NO 1: YES |
| 1.3.6.1.4.1.4756.20.501.20.1.151 | ColumnnidPort5LLFLogicPort6RemoteA | read-write | current | NID Series card Port5 link loss forwarding - Link/Rx Loss Port6 0: NO 1: YES |
| 1.3.6.1.4.1.4756.20.501.20.1.152 | ColumnnidPort5LLFLogicPort7RemoteA | read-write | current | NID Series card Port5 link loss forwarding - Link/Rx Loss Port7 0: NO 1: YES |
| 1.3.6.1.4.1.4756.20.501.20.1.153 | ColumnnidPort5LLFLogicPort8RemoteA | read-write | current | NID Series card Port5 link loss forwarding - Link/Rx Loss Port8 0: NO 1: YES |
| 1.3.6.1.4.1.4756.20.501.20.1.154 | ColumnnidPort6LLFLogicRemoteA | read-write | current | NID Series card Port6 link loss forwarding - Logic 0: AND 1: OR |
| 1.3.6.1.4.1.4756.20.501.20.1.155 | ColumnnidPort6LLFLogicPort1RemoteA | read-write | current | NID Series card Port6 link loss forwarding - Link/Rx Loss Port1 0: NO 1: YES |
| 1.3.6.1.4.1.4756.20.501.20.1.156 | ColumnnidPort6LLFLogicPort2RemoteA | read-write | current | NID Series card Port6 link loss forwarding - Link/Rx Loss Port2 0: NO 1: YES |
| 1.3.6.1.4.1.4756.20.501.20.1.157 | ColumnnidPort6LLFLogicPort3RemoteA | read-write | current | NID Series card Port6 link loss forwarding - Link/Rx Loss Port3 0: NO 1: YES |
| 1.3.6.1.4.1.4756.20.501.20.1.158 | ColumnnidPort6LLFLogicPort4RemoteA | read-write | current | NID Series card Port6 link loss forwarding - Link/Rx Loss Port4 0: NO 1: YES |
| 1.3.6.1.4.1.4756.20.501.20.1.159 | ColumnnidPort6LLFLogicPort5RemoteA | read-write | current | NID Series card Port6 link loss forwarding - Link/Rx Loss Port5 0: NO 1: YES |
| 1.3.6.1.4.1.4756.20.501.20.1.160 | ColumnnidPort6LLFLogicPort7RemoteA | read-write | current | NID Series card Port4 link loss forwarding - Link/Rx Loss Port7 0: NO 1: YES |
| 1.3.6.1.4.1.4756.20.501.20.1.161 | ColumnnidPort6LLFLogicPort8RemoteA | read-write | current | NID Series card Port6 link loss forwarding - Link/Rx Loss Port8 0: NO 1: YES |
| 1.3.6.1.4.1.4756.20.501.20.1.162 | ColumnnidPort7LLFLogicRemoteA | read-write | current | NID Series card Port7 link loss forwarding - Logic 0: AND 1: OR |
| 1.3.6.1.4.1.4756.20.501.20.1.163 | ColumnnidPort7LLFLogicPort1RemoteA | read-write | current | NID Series card Port7 link loss forwarding - Link/Rx Loss Port1 0: NO 1: YES |
| 1.3.6.1.4.1.4756.20.501.20.1.164 | ColumnnidPort7LLFLogicPort2RemoteA | read-write | current | NID Series card Port7 link loss forwarding - Link/Rx Loss Port2 0: NO 1: YES |
| 1.3.6.1.4.1.4756.20.501.20.1.165 | ColumnnidPort7LLFLogicPort3RemoteA | read-write | current | NID Series card Port7 link loss forwarding - Link/Rx Loss Port3 0: NO 1: YES |
| 1.3.6.1.4.1.4756.20.501.20.1.166 | ColumnnidPort7LLFLogicPort4RemoteA | read-write | current | NID Series card Port7 link loss forwarding - Link/Rx Loss Port4 0: NO 1: YES |
| 1.3.6.1.4.1.4756.20.501.20.1.167 | ColumnnidPort7LLFLogicPort5RemoteA | read-write | current | NID Series card Port7 link loss forwarding - Link/Rx Loss Port5 0: NO 1: YES |
| 1.3.6.1.4.1.4756.20.501.20.1.168 | ColumnnidPort7LLFLogicPort6RemoteA | read-write | current | NID Series card Port4 link loss forwarding - Link/Rx Loss Port6 0: NO 1: YES |
| 1.3.6.1.4.1.4756.20.501.20.1.169 | ColumnnidPort7LLFLogicPort8RemoteA | read-write | current | NID Series card Port7 link loss forwarding - Link/Rx Loss Port8 0: NO 1: YES |
| 1.3.6.1.4.1.4756.20.501.20.1.170 | ColumnnidPort8LLFLogicRemoteA | read-write | current | NID Series card Port8 link loss forwarding - Logic 0: AND 1: OR |
| 1.3.6.1.4.1.4756.20.501.20.1.171 | ColumnnidPort8LLFLogicPort1RemoteA | read-write | current | NID Series card Port8 link loss forwarding - Link/Rx Loss Port1 0: NO 1: YES |
| 1.3.6.1.4.1.4756.20.501.20.1.172 | ColumnnidPort8LLFLogicPort2RemoteA | read-write | current | NID Series card Port8 link loss forwarding - Link/Rx Loss Port2 0: NO 1: YES |
| 1.3.6.1.4.1.4756.20.501.20.1.173 | ColumnnidPort8LLFLogicPort3RemoteA | read-write | current | NID Series card Port5 link loss forwarding - Link/Rx Loss Port3 0: NO 1: YES |
| 1.3.6.1.4.1.4756.20.501.20.1.174 | ColumnnidPort8LLFLogicPort4RemoteA | read-write | current | NID Series card Port8 link loss forwarding - Link/Rx Loss Port4 0: NO 1: YES |
| 1.3.6.1.4.1.4756.20.501.20.1.175 | ColumnnidPort8LLFLogicPort5RemoteA | read-write | current | NID Series card Port8 link loss forwarding - Link/Rx Loss Port5 0: NO 1: YES |
| 1.3.6.1.4.1.4756.20.501.20.1.176 | ColumnnidPort8LLFLogicPort6RemoteA | read-write | current | NID Series card Port8 link loss forwarding - Link/Rx Loss Port6 0: NO 1: YES |
| 1.3.6.1.4.1.4756.20.501.20.1.177 | ColumnnidPort8LLFLogicPort7RemoteA | read-write | current | NID Series card Port8 link loss forwarding - Link/Rx Loss Port7 0: NO 1: YES |
| 1.3.6.1.4.1.4756.20.501.20.1.178 | ColumnnidPort1PacketsRxRemoteA | read-only | current | NID Series card port1 traffic overview:: Packets Rx |
| 1.3.6.1.4.1.4756.20.501.20.1.179 | ColumnnidPort1PacketsTxRemoteA | read-only | current | NID Series card port1 traffic overview:: Packets Tx |
| 1.3.6.1.4.1.4756.20.501.20.1.180 | ColumnnidPort1BytesRxRemoteA | read-only | current | NID Series card port1 traffic overview:: Bytes Rx |
| 1.3.6.1.4.1.4756.20.501.20.1.181 | ColumnnidPort1BytesTxRemoteA | read-only | current | NID Series card port1 traffic overview:: Bytes Tx |
| 1.3.6.1.4.1.4756.20.501.20.1.182 | ColumnnidPort1ErrorsRxRemoteA | read-only | current | NID Series card port1 traffic overview:: Errors Rx |
| 1.3.6.1.4.1.4756.20.501.20.1.183 | ColumnnidPort1ErrorsTxRemoteA | read-only | current | NID Series card port1 traffic overview:: Errors Tx |
| 1.3.6.1.4.1.4756.20.501.20.1.184 | ColumnnidPort1DropsRxRemoteA | read-only | current | NID Series card port1 traffic overview:: Drops Rx |
| 1.3.6.1.4.1.4756.20.501.20.1.185 | ColumnnidPort1DropsTxRemoteA | read-only | current | NID Series card port1 traffic overview:: Drops Tx |
| 1.3.6.1.4.1.4756.20.501.20.1.186 | ColumnnidPort1FilteredRxRemoteA | read-only | current | NID Series card port1 traffic overview:: Filtered Rx |
| 1.3.6.1.4.1.4756.20.501.20.1.187 | ColumnnidPort2PacketsRxRemoteA | read-only | current | NID Series card port2 traffic overview:: Packets Rx |
| 1.3.6.1.4.1.4756.20.501.20.1.188 | ColumnnidPort2PacketsTxRemoteA | read-only | current | NID Series card port2 traffic overview:: Packets Tx |
| 1.3.6.1.4.1.4756.20.501.20.1.189 | ColumnnidPort2BytesRxRemoteA | read-only | current | NID Series card port2 traffic overview:: Bytes Rx |
| 1.3.6.1.4.1.4756.20.501.20.1.190 | ColumnnidPort2BytesTxRemoteA | read-only | current | NID Series card port2 traffic overview:: Bytes Tx |
| 1.3.6.1.4.1.4756.20.501.20.1.191 | ColumnnidPort2ErrorsRxRemoteA | read-only | current | NID Series card port2 traffic overview:: Errors Rx |
| 1.3.6.1.4.1.4756.20.501.20.1.192 | ColumnnidPort2ErrorsTxRemoteA | read-only | current | NID Series card port2 traffic overview:: Errors Tx |
| 1.3.6.1.4.1.4756.20.501.20.1.193 | ColumnnidPort2DropsRxRemoteA | read-only | current | NID Series card port2 traffic overview:: Drops Rx |
| 1.3.6.1.4.1.4756.20.501.20.1.194 | ColumnnidPort2DropsTxRemoteA | read-only | current | NID Series card port2 traffic overview:: Drops Tx |
| 1.3.6.1.4.1.4756.20.501.20.1.195 | ColumnnidPort2FilteredRxRemoteA | read-only | current | NID Series card port2 traffic overview:: Filtered Rx |
| 1.3.6.1.4.1.4756.20.501.20.1.196 | ColumnnidPort3PacketsRxRemoteA | read-only | current | NID Series card port3 traffic overview:: Packets Rx |
| 1.3.6.1.4.1.4756.20.501.20.1.197 | ColumnnidPort3PacketsTxRemoteA | read-only | current | NID Series card port3 traffic overview:: Packets Tx |
| 1.3.6.1.4.1.4756.20.501.20.1.198 | ColumnnidPort3BytesRxRemoteA | read-only | current | NID Series card port3 traffic overview:: Bytes Rx |
| 1.3.6.1.4.1.4756.20.501.20.1.199 | ColumnnidPort3BytesTxRemoteA | read-only | current | NID Series card port3 traffic overview:: Bytes Tx |
| 1.3.6.1.4.1.4756.20.501.20.1.200 | ColumnnidPort3ErrorsRxRemoteA | read-only | current | NID Series card port3 traffic overview:: Errors Rx |
| 1.3.6.1.4.1.4756.20.501.20.1.201 | ColumnnidPort3ErrorsTxRemoteA | read-only | current | NID Series card port3 traffic overview:: Errors Tx |
| 1.3.6.1.4.1.4756.20.501.20.1.202 | ColumnnidPort3DropsRxRemoteA | read-only | current | NID Series card port3 traffic overview:: Drops Rx |
| 1.3.6.1.4.1.4756.20.501.20.1.203 | ColumnnidPort3DropsTxRemoteA | read-only | current | NID Series card port3 traffic overview:: Drops Tx |
| 1.3.6.1.4.1.4756.20.501.20.1.204 | ColumnnidPort3FilteredRxRemoteA | read-only | current | NID Series card port3 traffic overview:: Filtered Rx |
| 1.3.6.1.4.1.4756.20.501.20.1.205 | ColumnnidPort4PacketsRxRemoteA | read-only | current | NID Series card port4 traffic overview:: Packets Rx |
| 1.3.6.1.4.1.4756.20.501.20.1.206 | ColumnnidPort4PacketsTxRemoteA | read-only | current | NID Series card port4 traffic overview:: Packets Tx |
| 1.3.6.1.4.1.4756.20.501.20.1.207 | ColumnnidPort4BytesRxRemoteA | read-only | current | NID Series card port4 traffic overview:: Bytes Rx |
| 1.3.6.1.4.1.4756.20.501.20.1.208 | ColumnnidPort4BytesTxRemoteA | read-only | current | NID Series card port4 traffic overview:: Bytes Tx |
| 1.3.6.1.4.1.4756.20.501.20.1.209 | ColumnnidPort4ErrorsRxRemoteA | read-only | current | NID Series card port4 traffic overview:: Errors Rx |
| 1.3.6.1.4.1.4756.20.501.20.1.210 | ColumnnidPort4ErrorsTxRemoteA | read-only | current | NID Series card port4 traffic overview:: Errors Tx |
| 1.3.6.1.4.1.4756.20.501.20.1.211 | ColumnnidPort4DropsRxRemoteA | read-only | current | NID Series card port4 traffic overview:: Drops Rx |
| 1.3.6.1.4.1.4756.20.501.20.1.212 | ColumnnidPort4DropsTxRemoteA | read-only | current | NID Series card port4 traffic overview:: Drops Tx |
| 1.3.6.1.4.1.4756.20.501.20.1.213 | ColumnnidPort4FilteredRxRemoteA | read-only | current | NID Series card port4 traffic overview:: Filtered Rx |
| 1.3.6.1.4.1.4756.20.501.20.1.214 | ColumnnidPort5PacketsRxRemoteA | read-only | current | NID Series card port5 traffic overview:: Packets Rx |
| 1.3.6.1.4.1.4756.20.501.20.1.215 | ColumnnidPort5PacketsTxRemoteA | read-only | current | NID Series card port5 traffic overview:: Packets Tx |
| 1.3.6.1.4.1.4756.20.501.20.1.216 | ColumnnidPort5BytesRxRemoteA | read-only | current | NID Series card port5 traffic overview:: Bytes Rx |
| 1.3.6.1.4.1.4756.20.501.20.1.217 | ColumnnidPort5BytesTxRemoteA | read-only | current | NID Series card port5 traffic overview:: Bytes Tx |
| 1.3.6.1.4.1.4756.20.501.20.1.218 | ColumnnidPort5ErrorsRxRemoteA | read-only | current | NID Series card port5 traffic overview:: Errors Rx |
| 1.3.6.1.4.1.4756.20.501.20.1.219 | ColumnnidPort5ErrorsTxRemoteA | read-only | current | NID Series card port5 traffic overview:: Errors Tx |
| 1.3.6.1.4.1.4756.20.501.20.1.220 | ColumnnidPort5DropsRxRemoteA | read-only | current | NID Series card port5 traffic overview:: Drops Rx |
| 1.3.6.1.4.1.4756.20.501.20.1.221 | ColumnnidPort5DropsTxRemoteA | read-only | current | NID Series card port5 traffic overview:: Drops Tx |
| 1.3.6.1.4.1.4756.20.501.20.1.222 | ColumnnidPort5FilteredRxRemoteA | read-only | current | NID Series card port5 traffic overview:: Filtered Rx |
| 1.3.6.1.4.1.4756.20.501.20.1.223 | ColumnnidPort6PacketsRxRemoteA | read-only | current | NID Series card port6 traffic overview:: Packets Rx |
| 1.3.6.1.4.1.4756.20.501.20.1.224 | ColumnnidPort6PacketsTxRemoteA | read-only | current | NID Series card port6 traffic overview:: Packets Tx |
| 1.3.6.1.4.1.4756.20.501.20.1.225 | ColumnnidPort6BytesRxRemoteA | read-only | current | NID Series card port6 traffic overview:: Bytes Rx |
| 1.3.6.1.4.1.4756.20.501.20.1.226 | ColumnnidPort6BytesTxRemoteA | read-only | current | NID Series card port6 traffic overview:: Bytes Tx |
| 1.3.6.1.4.1.4756.20.501.20.1.227 | ColumnnidPort6ErrorsRxRemoteA | read-only | current | NID Series card port6 traffic overview:: Errors Rx |
| 1.3.6.1.4.1.4756.20.501.20.1.228 | ColumnnidPort6ErrorsTxRemoteA | read-only | current | NID Series card port6 traffic overview:: Errors Tx |
| 1.3.6.1.4.1.4756.20.501.20.1.229 | ColumnnidPort6DropsRxRemoteA | read-only | current | NID Series card port6 traffic overview:: Drops Rx |
| 1.3.6.1.4.1.4756.20.501.20.1.230 | ColumnnidPort6DropsTxRemoteA | read-only | current | NID Series card port6 traffic overview:: Drops Tx |
| 1.3.6.1.4.1.4756.20.501.20.1.231 | ColumnnidPort6FilteredRxRemoteA | read-only | current | NID Series card port6 traffic overview:: Filtered Rx |
| 1.3.6.1.4.1.4756.20.501.20.1.232 | ColumnnidPort7PacketsRxRemoteA | read-only | current | NID Series card port7 traffic overview:: Packets Rx |
| 1.3.6.1.4.1.4756.20.501.20.1.233 | ColumnnidPort7PacketsTxRemoteA | read-only | current | NID Series card port7 traffic overview:: Packets Tx |
| 1.3.6.1.4.1.4756.20.501.20.1.234 | ColumnnidPort7BytesRxRemoteA | read-only | current | NID Series card port7 traffic overview:: Bytes Rx |
| 1.3.6.1.4.1.4756.20.501.20.1.235 | ColumnnidPort7BytesTxRemoteA | read-only | current | NID Series card port7 traffic overview:: Bytes Tx |
| 1.3.6.1.4.1.4756.20.501.20.1.236 | ColumnnidPort7ErrorsRxRemoteA | read-only | current | NID Series card port7 traffic overview:: Errors Rx |
| 1.3.6.1.4.1.4756.20.501.20.1.237 | ColumnnidPort7ErrorsTxRemoteA | read-only | current | NID Series card port7 traffic overview:: Errors Tx |
| 1.3.6.1.4.1.4756.20.501.20.1.238 | ColumnnidPort7DropsRxRemoteA | read-only | current | NID Series card port7 traffic overview:: Drops Rx |
| 1.3.6.1.4.1.4756.20.501.20.1.239 | ColumnnidPort7DropsTxRemoteA | read-only | current | NID Series card port7 traffic overview:: Drops Tx |
| 1.3.6.1.4.1.4756.20.501.20.1.240 | ColumnnidPort7FilteredRxRemoteA | read-only | current | NID Series card port7 traffic overview:: Filtered Rx |
| 1.3.6.1.4.1.4756.20.501.20.1.241 | ColumnnidPort8PacketsRxRemoteA | read-only | current | NID Series card port8 traffic overview:: Packets Rx |
| 1.3.6.1.4.1.4756.20.501.20.1.242 | ColumnnidPort8PacketsTxRemoteA | read-only | current | NID Series card port8 traffic overview:: Packets Tx |
| 1.3.6.1.4.1.4756.20.501.20.1.243 | ColumnnidPort8BytesRxRemoteA | read-only | current | NID Series card port8 traffic overview:: Bytes Rx |
| 1.3.6.1.4.1.4756.20.501.20.1.244 | ColumnnidPort8BytesTxRemoteA | read-only | current | NID Series card port8 traffic overview:: Bytes Tx |
| 1.3.6.1.4.1.4756.20.501.20.1.245 | ColumnnidPort8ErrorsRxRemoteA | read-only | current | NID Series card port8 traffic overview:: Errors Rx |
| 1.3.6.1.4.1.4756.20.501.20.1.246 | ColumnnidPort8ErrorsTxRemoteA | read-only | current | NID Series card port8 traffic overview:: Errors Tx |
| 1.3.6.1.4.1.4756.20.501.20.1.247 | ColumnnidPort8DropsRxRemoteA | read-only | current | NID Series card port8 traffic overview:: Drops Rx |
| 1.3.6.1.4.1.4756.20.501.20.1.248 | ColumnnidPort8DropsTxRemoteA | read-only | current | NID Series card port8 traffic overview:: Drops Tx |
| 1.3.6.1.4.1.4756.20.501.20.1.249 | ColumnnidPort8FilteredRxRemoteA | read-only | current | NID Series card port8 traffic overview:: Filtered Rx |
| 1.3.6.1.4.1.4756.20.501.20.1.250 | ColumnnidAggrSourceMACAddrRemoteA | read-write | current | NID Series card Aggregation Mode Configuration: Source MAC Address 0: No 1: Yes |
| 1.3.6.1.4.1.4756.20.501.20.1.251 | ColumnnidAggrDestinationMACAddrRemoteA | read-write | current | NID Series card Aggregation Mode Configuration: Destination MAC Address 0: No 1: Yes |
| 1.3.6.1.4.1.4756.20.501.20.1.252 | ColumnnidAggrIPAddrRemoteA | read-write | current | NID Series card Aggregation Mode Configuration: IP Address 0: No 1: Yes |
| 1.3.6.1.4.1.4756.20.501.20.1.253 | ColumnnidAggrTCPUDPPortNumRemoteA | read-write | current | NID Series card Aggregation Mode Configuration: TCP/UDP Port Number 0: No 1: Yes |
| 1.3.6.1.4.1.4756.20.501.20.1.254 | ColumnnidAggrGroupPort1ConfRemoteA | read-write | current | NID Series card Aggregation Group Port1 Configuration: 0: Normal 1: ID1 2: ID2 3: ID3 4: ID4 |
| 1.3.6.1.4.1.4756.20.501.20.1.255 | ColumnnidAggrGroupPort2ConfRemoteA | read-write | current | NID Series card Aggregation Group Port2 Configuration: 0: Normal 1: ID1 2: ID2 3: ID3 4: ID4 |
| 1.3.6.1.4.1.4756.20.501.20.1.256 | ColumnnidAggrGroupPort3ConfRemoteA | read-write | current | NID Series card Aggregation Group Port3 Configuration: 0: Normal 1: ID1 2: ID2 3: ID3 4: ID4 |
| 1.3.6.1.4.1.4756.20.501.20.1.257 | ColumnnidAggrGroupPort4ConfRemoteA | read-write | current | NID Series card Aggregation Group Port4 Configuration: 0: Normal 1: ID1 2: ID2 3: ID3 4: ID4 |
| 1.3.6.1.4.1.4756.20.501.20.1.258 | ColumnnidAggrGroupPort5ConfRemoteA | read-write | current | NID Series card Aggregation Group Port5 Configuration: 0: Normal 1: ID1 2: ID2 3: ID3 4: ID4 |
| 1.3.6.1.4.1.4756.20.501.20.1.259 | ColumnnidAggrGroupPort6ConfRemoteA | read-write | current | NID Series card Aggregation Group Port6 Configuration: 0: Normal 1: ID1 2: ID2 3: ID3 4: ID4 |
| 1.3.6.1.4.1.4756.20.501.20.1.260 | ColumnnidAggrGroupPort7ConfRemoteA | read-write | current | NID Series card Aggregation Group Port7 Configuration: 0: Normal 1: ID1 2: ID2 3: ID3 4: ID4 |
| 1.3.6.1.4.1.4756.20.501.20.1.261 | ColumnnidAggrGroupPort8ConfRemoteA | read-write | current | NID Series card Aggregation Group Port8 Configuration: 0: Normal 1: ID1 2: ID2 3: ID3 4: ID4 |
| 1.3.6.1.4.1.4756.20.501.20.1.262 | ColumnnidPort1LACPEnabledRemoteA | read-write | current | NID Series card Port1 LACP Enabled: 0: No 1: Yes |
| 1.3.6.1.4.1.4756.20.501.20.1.263 | ColumnnidPort1LACPKEYRemoteA | read-write | current | NID Series card Port1 LACP Key value: The Key value incurred by the port, range 0-65535.The value of 0 means auto. |
| 1.3.6.1.4.1.4756.20.501.20.1.264 | ColumnnidPort1LACPRoleRemoteA | read-write | current | NID Series card Port1 LACP Role: 0: Passive 1: Active |
| 1.3.6.1.4.1.4756.20.501.20.1.265 | ColumnnidPort1LACPTimeOutRemoteA | read-write | current | NID Series card Port1 LACP Time out: 0: Slow 1: Fast |
| 1.3.6.1.4.1.4756.20.501.20.1.266 | ColumnnidPort1LACPPrioRemoteA | read-write | current | NID Series card Port1 LACP priority: The Key value incurred by the port, range 1-65535. |
| 1.3.6.1.4.1.4756.20.501.20.1.267 | ColumnnidPort2LACPEnabledRemoteA | read-write | current | NID Series card Port2 LACP Enabled: 0: No 1: Yes |
| 1.3.6.1.4.1.4756.20.501.20.1.268 | ColumnnidPort2LACPKEYRemoteA | read-write | current | NID Series card Port2 LACP Key value: The Key value incurred by the port, range 0-65535.The value of 0 means auto. |
| 1.3.6.1.4.1.4756.20.501.20.1.269 | ColumnnidPort2LACPRoleRemoteA | read-write | current | NID Series card Port2 LACP Role: 0: Passive 1: Active |
| 1.3.6.1.4.1.4756.20.501.20.1.270 | ColumnnidPort2LACPTimeOutRemoteA | read-write | current | NID Series card Port2 LACP Time out: 0: Slow 1: Fast |
| 1.3.6.1.4.1.4756.20.501.20.1.271 | ColumnnidPort2LACPPrioRemoteA | read-write | current | NID Series card Port2 LACP priority: The Key value incurred by the port, range 1-65535. |
| 1.3.6.1.4.1.4756.20.501.20.1.272 | ColumnnidPort3LACPEnabledRemoteA | read-write | current | NID Series card Port3 LACP Enabled: 0: No 1: Yes |
| 1.3.6.1.4.1.4756.20.501.20.1.273 | ColumnnidPort3LACPKEYRemoteA | read-write | current | NID Series card Port3 LACP Key value: The Key value incurred by the port, range 0-65535.The value of 0 means auto. |
| 1.3.6.1.4.1.4756.20.501.20.1.274 | ColumnnidPort3LACPRoleRemoteA | read-write | current | NID Series card Port3 LACP Role: 0: Passive 1: Active |
| 1.3.6.1.4.1.4756.20.501.20.1.275 | ColumnnidPort3LACPTimeOutRemoteA | read-write | current | NID Series card Port3 LACP Time out: 0: Slow 1: Fast |
| 1.3.6.1.4.1.4756.20.501.20.1.276 | ColumnnidPort3LACPPrioRemoteA | read-write | current | NID Series card Port3 LACP priority: The Key value incurred by the port, range 1-65535. |
| 1.3.6.1.4.1.4756.20.501.20.1.277 | ColumnnidPort4LACPEnabledRemoteA | read-write | current | NID Series card Port4 LACP Enabled: 0: No 1: Yes |
| 1.3.6.1.4.1.4756.20.501.20.1.278 | ColumnnidPort4LACPKEYRemoteA | read-write | current | NID Series card Port4 LACP Key value: The Key value incurred by the port, range 0-65535.The value of 0 means auto. |
| 1.3.6.1.4.1.4756.20.501.20.1.279 | ColumnnidPort4LACPRoleRemoteA | read-write | current | NID Series card Port4 LACP Role: 0: Passive 1: Active |
| 1.3.6.1.4.1.4756.20.501.20.1.280 | ColumnnidPort4LACPTimeOutRemoteA | read-write | current | NID Series card Port4 LACP Time out: 0: Slow 1: Fast |
| 1.3.6.1.4.1.4756.20.501.20.1.281 | ColumnnidPort4LACPPrioRemoteA | read-write | current | NID Series card Port4 LACP priority: The Key value incurred by the port, range 1-65535. |
| 1.3.6.1.4.1.4756.20.501.20.1.282 | ColumnnidPort5LACPEnabledRemoteA | read-write | current | NID Series card Port5 LACP Enabled: 0: No 1: Yes |
| 1.3.6.1.4.1.4756.20.501.20.1.283 | ColumnnidPort5LACPKEYRemoteA | read-write | current | NID Series card Port5 LACP Key value: The Key value incurred by the port, range 0-65535.The value of 0 means auto. |
| 1.3.6.1.4.1.4756.20.501.20.1.284 | ColumnnidPort5LACPRoleRemoteA | read-write | current | NID Series card Port5 LACP Role: 0: Passive 1: Active |
| 1.3.6.1.4.1.4756.20.501.20.1.285 | ColumnnidPort5LACPTimeOutRemoteA | read-write | current | NID Series card Port5 LACP Time out: 0: Slow 1: Fast |
| 1.3.6.1.4.1.4756.20.501.20.1.286 | ColumnnidPort5LACPPrioRemoteA | read-write | current | NID Series card Port5 LACP priority: The Key value incurred by the port, range 1-65535. |
| 1.3.6.1.4.1.4756.20.501.20.1.287 | ColumnnidPort6LACPEnabledRemoteA | read-write | current | NID Series card Port6 LACP Enabled: 0: No 1: Yes |
| 1.3.6.1.4.1.4756.20.501.20.1.288 | ColumnnidPort6LACPKEYRemoteA | read-write | current | NID Series card Port6 LACP Key value: The Key value incurred by the port, range 0-65535.The value of 0 means auto. |
| 1.3.6.1.4.1.4756.20.501.20.1.289 | ColumnnidPort6LACPRoleRemoteA | read-write | current | NID Series card Port6 LACP Role: 0: Passive 1: Active |
| 1.3.6.1.4.1.4756.20.501.20.1.290 | ColumnnidPort6LACPTimeOutRemoteA | read-write | current | NID Series card Port6 LACP Time out: 0: Slow 1: Fast |
| 1.3.6.1.4.1.4756.20.501.20.1.291 | ColumnnidPort6LACPPrioRemoteA | read-write | current | NID Series card Port6 LACP priority: The Key value incurred by the port, range 1-65535. |
| 1.3.6.1.4.1.4756.20.501.20.1.292 | ColumnnidPort7LACPEnabledRemoteA | read-write | current | NID Series card Port7 LACP Enabled: 0: No 1: Yes |
| 1.3.6.1.4.1.4756.20.501.20.1.293 | ColumnnidPort7LACPKEYRemoteA | read-write | current | NID Series card Port7 LACP Key value: The Key value incurred by the port, range 0-65535.The value of 0 means auto. |
| 1.3.6.1.4.1.4756.20.501.20.1.294 | ColumnnidPort7LACPRoleRemoteA | read-write | current | NID Series card Port7 LACP Role: 0: Passive 1: Active |
| 1.3.6.1.4.1.4756.20.501.20.1.295 | ColumnnidPort7LACPTimeOutRemoteA | read-write | current | NID Series card Port7 LACP Time out: 0: Slow 1: Fast |
| 1.3.6.1.4.1.4756.20.501.20.1.296 | ColumnnidPort7LACPPrioRemoteA | read-write | current | NID Series card Port7 LACP priority: The Key value incurred by the port, range 1-65535. |
| 1.3.6.1.4.1.4756.20.501.20.1.297 | ColumnnidPort8LACPEnabledRemoteA | read-write | current | NID Series card Port8 LACP Enabled: 0: No 1: Yes |
| 1.3.6.1.4.1.4756.20.501.20.1.298 | ColumnnidPort8LACPKEYRemoteA | read-write | current | NID Series card Port8 LACP Key value: The Key value incurred by the port, range 0-65535.The value of 0 means auto. |
| 1.3.6.1.4.1.4756.20.501.20.1.299 | ColumnnidPort8LACPRoleRemoteA | read-write | current | NID Series card Port8 LACP Role: 0: Passive 1: Active |
| 1.3.6.1.4.1.4756.20.501.20.1.300 | ColumnnidPort8LACPTimeOutRemoteA | read-write | current | NID Series card Port8 LACP Time out: 0: Slow 1: Fast |
| 1.3.6.1.4.1.4756.20.501.20.1.301 | ColumnnidPort8LACPPrioRemoteA | read-write | current | NID Series card Port8 LACP priority: The Key value incurred by the port, range 1-65535. |
| 1.3.6.1.4.1.4756.20.501.20.1.302 | ColumnnidPort1LACPstsRemoteA | read-only | current | NID Series card Port1 LACP status: 0: No 1: Yes 2: Standby |
| 1.3.6.1.4.1.4756.20.501.20.1.303 | ColumnnidPort1LACPKEYstsRemoteA | read-only | current | NID Series card Port1 LACP status: Key |
| 1.3.6.1.4.1.4756.20.501.20.1.304 | ColumnnidPort1LACPAggrIDstsRemoteA | read-only | current | NID Series card Port1 LACP status: Aggr ID |
| 1.3.6.1.4.1.4756.20.501.20.1.305 | ColumnnidPort1LACPParnterSysIDstsRemoteA | read-only | current | NID Series card Port1 LACP status: Parnter System ID |
| 1.3.6.1.4.1.4756.20.501.20.1.306 | ColumnnidPort1LACPParnterPortstsRemoteA | read-only | current | NID Series card Port1 LACP status: Parnter Port Status |
| 1.3.6.1.4.1.4756.20.501.20.1.307 | ColumnnidPort1LACPParnterProistsRemoteA | read-only | current | NID Series card Port1 LACP status: Parnter Priority |
| 1.3.6.1.4.1.4756.20.501.20.1.308 | ColumnnidPort2LACPstsRemoteA | read-only | current | NID Series card Port2 LACP status: 0: No 1: Yes 2: Standby |
| 1.3.6.1.4.1.4756.20.501.20.1.309 | ColumnnidPort2LACPKEYstsRemoteA | read-only | current | NID Series card Port2 LACP status: Key |
| 1.3.6.1.4.1.4756.20.501.20.1.310 | ColumnnidPort2LACPAggrIDstsRemoteA | read-only | current | NID Series card Port2 LACP status: Aggr ID |
| 1.3.6.1.4.1.4756.20.501.20.1.311 | ColumnnidPort2LACPParnterSysIDstsRemoteA | read-only | current | NID Series card Port2 LACP status: Parnter System ID |
| 1.3.6.1.4.1.4756.20.501.20.1.312 | ColumnnidPort2LACPParnterPortstsRemoteA | read-only | current | NID Series card Port2 LACP status: Parnter Port Status |
| 1.3.6.1.4.1.4756.20.501.20.1.313 | ColumnnidPort2LACPParnterProistsRemoteA | read-only | current | NID Series card Port2 LACP status: Parnter Priority |
| 1.3.6.1.4.1.4756.20.501.20.1.314 | ColumnnidPort3LACPstsRemoteA | read-only | current | NID Series card Port3 LACP status: 0: No 1: Yes 2: Standby |
| 1.3.6.1.4.1.4756.20.501.20.1.315 | ColumnnidPort3LACPKEYstsRemoteA | read-only | current | NID Series card Port3 LACP status: Key |
| 1.3.6.1.4.1.4756.20.501.20.1.316 | ColumnnidPort3LACPAggrIDstsRemoteA | read-only | current | NID Series card Port3 LACP status: Aggr ID |
| 1.3.6.1.4.1.4756.20.501.20.1.317 | ColumnnidPort3LACPParnterSysIDstsRemoteA | read-only | current | NID Series card Port3 LACP status: Parnter System ID |
| 1.3.6.1.4.1.4756.20.501.20.1.318 | ColumnnidPort3LACPParnterPortstsRemoteA | read-only | current | NID Series card Port3 LACP status: Parnter Port Status |
| 1.3.6.1.4.1.4756.20.501.20.1.319 | ColumnnidPort3LACPParnterProistsRemoteA | read-only | current | NID Series card Port3 LACP status: Parnter Priority |
| 1.3.6.1.4.1.4756.20.501.20.1.320 | ColumnnidPort4LACPstsRemoteA | read-only | current | NID Series card Port4 LACP status: 0: No 1: Yes 2: Standby |
| 1.3.6.1.4.1.4756.20.501.20.1.321 | ColumnnidPort4LACPKEYstsRemoteA | read-only | current | NID Series card Port4 LACP status: Key |
| 1.3.6.1.4.1.4756.20.501.20.1.322 | ColumnnidPort4LACPAggrIDstsRemoteA | read-only | current | NID Series card Port4 LACP status: Aggr ID |
| 1.3.6.1.4.1.4756.20.501.20.1.323 | ColumnnidPort4LACPParnterSysIDstsRemoteA | read-only | current | NID Series card Port4 LACP status: Parnter System ID |
| 1.3.6.1.4.1.4756.20.501.20.1.324 | ColumnnidPort4LACPParnterPortstsRemoteA | read-only | current | NID Series card Port4 LACP status: Parnter Port Status |
| 1.3.6.1.4.1.4756.20.501.20.1.325 | ColumnnidPort4LACPParnterProistsRemoteA | read-only | current | NID Series card Port4 LACP status: Parnter Priority |
| 1.3.6.1.4.1.4756.20.501.20.1.326 | ColumnnidPort5LACPstsRemoteA | read-only | current | NID Series card Port5 LACP status: 0: No 1: Yes 2: Standby |
| 1.3.6.1.4.1.4756.20.501.20.1.327 | ColumnnidPort5LACPKEYstsRemoteA | read-only | current | NID Series card Port5 LACP status: Key |
| 1.3.6.1.4.1.4756.20.501.20.1.328 | ColumnnidPort5LACPAggrIDstsRemoteA | read-only | current | NID Series card Port5 LACP status: Aggr ID |
| 1.3.6.1.4.1.4756.20.501.20.1.329 | ColumnnidPort5LACPParnterSysIDstsRemoteA | read-only | current | NID Series card Port5 LACP status: Parnter System ID |
| 1.3.6.1.4.1.4756.20.501.20.1.330 | ColumnnidPort5LACPParnterPortstsRemoteA | read-only | current | NID Series card Port5 LACP status: Parnter Port Status |
| 1.3.6.1.4.1.4756.20.501.20.1.331 | ColumnnidPort5LACPParnterProistsRemoteA | read-only | current | NID Series card Port5 LACP status: Parnter Priority |
| 1.3.6.1.4.1.4756.20.501.20.1.332 | ColumnnidPort6LACPstsRemoteA | read-only | current | NID Series card Port6 LACP status: 0: No 1: Yes 2: Standby |
| 1.3.6.1.4.1.4756.20.501.20.1.333 | ColumnnidPort6LACPKEYstsRemoteA | read-only | current | NID Series card Port6 LACP status: Key |
| 1.3.6.1.4.1.4756.20.501.20.1.334 | ColumnnidPort6LACPAggrIDstsRemoteA | read-only | current | NID Series card Port6 LACP status: Aggr ID |
| 1.3.6.1.4.1.4756.20.501.20.1.335 | ColumnnidPort6LACPParnterSysIDstsRemoteA | read-only | current | NID Series card Port6 LACP status: Parnter System ID |
| 1.3.6.1.4.1.4756.20.501.20.1.336 | ColumnnidPort6LACPParnterPortstsRemoteA | read-only | current | NID Series card Port6 LACP status: Parnter Port Status |
| 1.3.6.1.4.1.4756.20.501.20.1.337 | ColumnnidPort6LACPParnterProistsRemoteA | read-only | current | NID Series card Port6 LACP status: Parnter Priority |
| 1.3.6.1.4.1.4756.20.501.20.1.338 | ColumnnidPort7LACPstsRemoteA | read-only | current | NID Series card Port7 LACP status: 0: No 1: Yes 2: Standby |
| 1.3.6.1.4.1.4756.20.501.20.1.339 | ColumnnidPort7LACPKEYstsRemoteA | read-only | current | NID Series card Port7 LACP status: Key |
| 1.3.6.1.4.1.4756.20.501.20.1.340 | ColumnnidPort7LACPAggrIDstsRemoteA | read-only | current | NID Series card Port7 LACP status: Aggr ID |
| 1.3.6.1.4.1.4756.20.501.20.1.341 | ColumnnidPort7LACPParnterSysIDstsRemoteA | read-only | current | NID Series card Port7 LACP status: Parnter System ID |
| 1.3.6.1.4.1.4756.20.501.20.1.342 | ColumnnidPort7LACPParnterPortstsRemoteA | read-only | current | NID Series card Port7 LACP status: Parnter Port Status |
| 1.3.6.1.4.1.4756.20.501.20.1.343 | ColumnnidPort7LACPParnterProistsRemoteA | read-only | current | NID Series card Port7 LACP status: Parnter Priority |
| 1.3.6.1.4.1.4756.20.501.20.1.344 | ColumnnidPort8LACPstsRemoteA | read-only | current | NID Series card Port8 LACP status: 0: No 1: Yes 2: Standby |
| 1.3.6.1.4.1.4756.20.501.20.1.345 | ColumnnidPort8LACPKEYstsRemoteA | read-only | current | NID Series card Port8 LACP status: Key |
| 1.3.6.1.4.1.4756.20.501.20.1.346 | ColumnnidPort8LACPAggrIDstsRemoteA | read-only | current | NID Series card Port8 LACP status: Aggr ID |
| 1.3.6.1.4.1.4756.20.501.20.1.347 | ColumnnidPort8LACPParnterSysIDstsRemoteA | read-only | current | NID Series card Port8 LACP status: Parnter System ID |
| 1.3.6.1.4.1.4756.20.501.20.1.348 | ColumnnidPort8LACPParnterPortstsRemoteA | read-only | current | NID Series card Port8 LACP status: Parnter Port Status |
| 1.3.6.1.4.1.4756.20.501.20.1.349 | ColumnnidPort8LACPParnterProistsRemoteA | read-only | current | NID Series card Port8 LACP status: Parnter Priority |
| 1.3.6.1.4.1.4756.20.501.20.1.350 | ColumnnidOAMPort1EnableRemoteA | read-write | current | NID Series card Port1 OAM: 0: Off 1: On |
| 1.3.6.1.4.1.4756.20.501.20.1.351 | ColumnnidOAMPort1ModeRemoteA | read-write | current | NID Series card Port1 OAM: 0: Passive 1: Active |
| 1.3.6.1.4.1.4756.20.501.20.1.352 | ColumnnidOAMPort1LoopBackRemoteA | read-write | current | NID Series card Port1 OAM LoopBack: 0: Off 1: On |
| 1.3.6.1.4.1.4756.20.501.20.1.353 | ColumnnidOAMPort1LinkMonitorRemoteA | read-write | current | NID Series card Port1 OAM Link Monitor: 0: Off 1: On |
| 1.3.6.1.4.1.4756.20.501.20.1.354 | ColumnnidOAMPort1MIBRetrievalRemoteA | read-write | current | NID Series card Port1 OAM MIB Retrieval: 0: Off 1: On |
| 1.3.6.1.4.1.4756.20.501.20.1.355 | ColumnnidOAMPort1LoopBackOPRemoteA | read-write | current | NID Series card Port1 OAM LoopBack operation: 0: Off 1: On |
| 1.3.6.1.4.1.4756.20.501.20.1.356 | ColumnnidOAMPort2EnableRemoteA | read-write | current | NID Series card Port2 OAM: 0: Off 1: On |
| 1.3.6.1.4.1.4756.20.501.20.1.357 | ColumnnidOAMPort2ModeRemoteA | read-write | current | NID Series card Port2 OAM: 0: Passive 1: Active |
| 1.3.6.1.4.1.4756.20.501.20.1.358 | ColumnnidOAMPort2LoopBackRemoteA | read-write | current | NID Series card Port2 OAM LoopBack: 0: Off 1: On |
| 1.3.6.1.4.1.4756.20.501.20.1.359 | ColumnnidOAMPort2LinkMonitorRemoteA | read-write | current | NID Series card Port2 OAM Link Monitor: 0: Off 1: On |
| 1.3.6.1.4.1.4756.20.501.20.1.360 | ColumnnidOAMPort2MIBRetrievalRemoteA | read-write | current | NID Series card Port2 OAM MIB Retrieval: 0: Off 1: On |
| 1.3.6.1.4.1.4756.20.501.20.1.361 | ColumnnidOAMPort2LoopBackOPRemoteA | read-write | current | NID Series card Port2 OAM LoopBack operation: 0: Off 1: On |
| 1.3.6.1.4.1.4756.20.501.20.1.362 | ColumnnidOAMPort3EnableRemoteA | read-write | current | NID Series card Port3 OAM: 0: Off 1: On |
| 1.3.6.1.4.1.4756.20.501.20.1.363 | ColumnnidOAMPort3ModeRemoteA | read-write | current | NID Series card Port3 OAM: 0: Passive 1: Active |
| 1.3.6.1.4.1.4756.20.501.20.1.364 | ColumnnidOAMPort3LoopBackRemoteA | read-write | current | NID Series card Port3 OAM: 0: Off 1: On |
| 1.3.6.1.4.1.4756.20.501.20.1.365 | ColumnnidOAMPort3LinkMonitorRemoteA | read-write | current | NID Series card Port3 OAM Link Monitor: 0: Off 1: On |
| 1.3.6.1.4.1.4756.20.501.20.1.366 | ColumnnidOAMPort3MIBRetrievalRemoteA | read-write | current | NID Series card Port3 OAM MIB Retrieval: 0: Off 1: On |
| 1.3.6.1.4.1.4756.20.501.20.1.367 | ColumnnidOAMPort3LoopBackOPRemoteA | read-write | current | NID Series card Port3 OAM LoopBack operation: 0: Disable 1: Enable |
| 1.3.6.1.4.1.4756.20.501.20.1.368 | ColumnnidOAMPort4EnableRemoteA | read-write | current | NID Series card Port4 OAM: 0: Off 1: On |
| 1.3.6.1.4.1.4756.20.501.20.1.369 | ColumnnidOAMPort4ModeRemoteA | read-write | current | NID Series card Port4 OAM: 0: Passive 1: Active |
| 1.3.6.1.4.1.4756.20.501.20.1.370 | ColumnnidOAMPort4LoopBackRemoteA | read-write | current | NID Series card Port4 OAM: 0: Off 1: On |
| 1.3.6.1.4.1.4756.20.501.20.1.371 | ColumnnidOAMPort4LinkMonitorRemoteA | read-write | current | NID Series card Port4 OAM Link Monitor: 0: Off 1: On |
| 1.3.6.1.4.1.4756.20.501.20.1.372 | ColumnnidOAMPort4MIBRetrievalRemoteA | read-write | current | NID Series card Port4 OAM MIB Retrieval: 0: Off 1: On |
| 1.3.6.1.4.1.4756.20.501.20.1.373 | ColumnnidOAMPort4LoopBackOPRemoteA | read-write | current | NID Series card Port4 OAM LoopBack operation: 0: On 1: Off |
| 1.3.6.1.4.1.4756.20.501.20.1.374 | ColumnnidOAMPort5EnableRemoteA | read-write | current | NID Series card Port5 OAM: 0: Off 1: On |
| 1.3.6.1.4.1.4756.20.501.20.1.375 | ColumnnidOAMPort5ModeRemoteA | read-write | current | NID Series card Port5 OAM: 0: Passive 1: Active |
| 1.3.6.1.4.1.4756.20.501.20.1.376 | ColumnnidOAMPort5LoopBackRemoteA | read-write | current | NID Series card Port5 OAM: 0: Off 1: On |
| 1.3.6.1.4.1.4756.20.501.20.1.377 | ColumnnidOAMPort5LinkMonitorRemoteA | read-write | current | NID Series card Port5 OAM Link Monitor: 0: Off 1: On |
| 1.3.6.1.4.1.4756.20.501.20.1.378 | ColumnnidOAMPort5MIBRetrievalRemoteA | read-write | current | NID Series card Port5 OAM MIB Retrieval: 0: Off 1: On |
| 1.3.6.1.4.1.4756.20.501.20.1.379 | ColumnnidOAMPort5LoopBackOPRemoteA | read-write | current | NID Series card Port5 OAM LoopBack operation: 0: On 1: Off |
| 1.3.6.1.4.1.4756.20.501.20.1.380 | ColumnnidOAMPort6EnableRemoteA | read-write | current | NID Series card Port6 OAM: 0: Off 1: On |
| 1.3.6.1.4.1.4756.20.501.20.1.381 | ColumnnidOAMPort6ModeRemoteA | read-write | current | NID Series card Port6 OAM: 0: Passive 1: Active |
| 1.3.6.1.4.1.4756.20.501.20.1.382 | ColumnnidOAMPort6LoopBackRemoteA | read-write | current | NID Series card Port6 OAM: 0: Off 1: On |
| 1.3.6.1.4.1.4756.20.501.20.1.383 | ColumnnidOAMPort6LinkMonitorRemoteA | read-write | current | NID Series card Port6 OAM Link Monitor: 0: Off 1: On |
| 1.3.6.1.4.1.4756.20.501.20.1.384 | ColumnnidOAMPort6MIBRetrievalRemoteA | read-write | current | NID Series card Port6 OAM MIB Retrieval: 0: Off 1: On |
| 1.3.6.1.4.1.4756.20.501.20.1.385 | ColumnnidOAMPort6LoopBackOPRemoteA | read-write | current | NID Series card Port6 OAM LoopBack operation: 0: On 1: Off |
| 1.3.6.1.4.1.4756.20.501.20.1.386 | ColumnnidOAMPort7EnableRemoteA | read-write | current | NID Series card Port7 OAM: 0: Off 1: On |
| 1.3.6.1.4.1.4756.20.501.20.1.387 | ColumnnidOAMPort7ModeRemoteA | read-write | current | NID Series card Port7 OAM: 0: Passive 1: Active |
| 1.3.6.1.4.1.4756.20.501.20.1.388 | ColumnnidOAMPort7LoopBackRemoteA | read-write | current | NID Series card Port7 OAM: 0: Off 1: On |
| 1.3.6.1.4.1.4756.20.501.20.1.389 | ColumnnidOAMPort7LinkMonitorRemoteA | read-write | current | NID Series card Port7 OAM Link Monitor: 0: Off 1: On |
| 1.3.6.1.4.1.4756.20.501.20.1.390 | ColumnnidOAMPort7MIBRetrievalRemoteA | read-write | current | NID Series card Port7 OAM MIB Retrieval: 0: Off 1: On |
| 1.3.6.1.4.1.4756.20.501.20.1.391 | ColumnnidOAMPort7LoopBackOPRemoteA | read-write | current | NID Series card Port7 OAM LoopBack operation: 0: On 1: Off |
| 1.3.6.1.4.1.4756.20.501.20.1.392 | ColumnnidOAMPort8EnableRemoteA | read-write | current | NID Series card Port8 OAM: 0: Off 1: On |
| 1.3.6.1.4.1.4756.20.501.20.1.393 | ColumnnidOAMPort8ModeRemoteA | read-write | current | NID Series card Port8 OAM: 0: Passive 1: Active |
| 1.3.6.1.4.1.4756.20.501.20.1.394 | ColumnnidOAMPort8LoopBackRemoteA | read-write | current | NID Series card Port8 OAM: 0: Off 1: On |
| 1.3.6.1.4.1.4756.20.501.20.1.395 | ColumnnidOAMPort8LinkMonitorRemoteA | read-write | current | NID Series card Port8 OAM Link Monitor: 0: Off 1: On |
| 1.3.6.1.4.1.4756.20.501.20.1.396 | ColumnnidOAMPort8MIBRetrievalRemoteA | read-write | current | NID Series card Port8 OAM MIB Retrieval: 0: Off 1: On |
| 1.3.6.1.4.1.4756.20.501.20.1.397 | ColumnnidOAMPort8LoopBackOPRemoteA | read-write | current | NID Series card Port8 OAM LoopBack operation: 0: On 1: Off |
| 1.3.6.1.4.1.4756.20.501.20.1.398 | ColumnnidPort1EFEErrorWindowRemoteA | read-write | current | NID Series card Port1 Link Event Configuration: Error Frame Event - Error Window |
| 1.3.6.1.4.1.4756.20.501.20.1.399 | ColumnnidPort1EFEErrorThresholdRemoteA | read-write | current | NID Series card Port1 Link Event Configuration: Error Frame Event - Error Threshold |
| 1.3.6.1.4.1.4756.20.501.20.1.400 | ColumnnidPort1SPEEErrorWindowRemoteA | read-write | current | NID Series card Port1 Link Event Configuration: Symbol Period Error Event - Error Window |
| 1.3.6.1.4.1.4756.20.501.20.1.401 | ColumnnidPort1SPEEErrorThresholdRemoteA | read-write | current | NID Series card Port1 Link Event Configuration: Symbol Period Error Event - Error Threshold |
| 1.3.6.1.4.1.4756.20.501.20.1.402 | ColumnnidPort1SSEErrorWindowRemoteA | read-write | current | NID Series card Port1 Link Event Configuration: Seconds Summary Event - Error Window |
| 1.3.6.1.4.1.4756.20.501.20.1.403 | ColumnnidPort1SSEErrorThresholdRemoteA | read-write | current | NID Series card Port1 Link Event Configuration: Seconds Summary Event - Error Threshold |
| 1.3.6.1.4.1.4756.20.501.20.1.404 | ColumnnidPort2EFEErrorWindowRemoteA | read-write | current | NID Series card Port2 Link Event Configuration: Error Frame Event - Error Window |
| 1.3.6.1.4.1.4756.20.501.20.1.405 | ColumnnidPort2EFEErrorThresholdRemoteA | read-write | current | NID Series card Port2 Link Event Configuration: Error Frame Event - Error Threshold |
| 1.3.6.1.4.1.4756.20.501.20.1.406 | ColumnnidPort2SPEEErrorWindowRemoteA | read-write | current | NID Series card Port2 Link Event Configuration: Symbol Period Error Event - Error Window |
| 1.3.6.1.4.1.4756.20.501.20.1.407 | ColumnnidPort2SPEEErrorThresholdRemoteA | read-write | current | NID Series card Port2 Link Event Configuration: Symbol Period Error Event - Error Threshold |
| 1.3.6.1.4.1.4756.20.501.20.1.408 | ColumnnidPort2SSEErrorWindowRemoteA | read-write | current | NID Series card Port2 Link Event Configuration: Seconds Summary Event - Error Window |
| 1.3.6.1.4.1.4756.20.501.20.1.409 | ColumnnidPort2SSEErrorThresholdRemoteA | read-write | current | NID Series card Port2 Link Event Configuration: Seconds Summary Event - Error Threshold |
| 1.3.6.1.4.1.4756.20.501.20.1.410 | ColumnnidPort3EFEErrorWindowRemoteA | read-write | current | NID Series card Port3 Link Event Configuration: Error Frame Event - Error Window |
| 1.3.6.1.4.1.4756.20.501.20.1.411 | ColumnnidPort3EFEErrorThresholdRemoteA | read-write | current | NID Series card Port3 Link Event Configuration: Error Frame Event - Error Threshold |
| 1.3.6.1.4.1.4756.20.501.20.1.412 | ColumnnidPort3SPEEErrorWindowRemoteA | read-write | current | NID Series card Port3 Link Event Configuration: Symbol Period Error Event - Error Window |
| 1.3.6.1.4.1.4756.20.501.20.1.413 | ColumnnidPort3SPEEErrorThresholdRemoteA | read-write | current | NID Series card Port3 Link Event Configuration: Symbol Period Error Event - Error Threshold |
| 1.3.6.1.4.1.4756.20.501.20.1.414 | ColumnnidPort3SSEErrorWindowRemoteA | read-write | current | NID Series card Port3 Link Event Configuration: Seconds Summary Event - Error Window |
| 1.3.6.1.4.1.4756.20.501.20.1.415 | ColumnnidPort3SSEErrorThresholdRemoteA | read-write | current | NID Series card Port3 Link Event Configuration: Seconds Summary Event - Error Threshold |
| 1.3.6.1.4.1.4756.20.501.20.1.416 | ColumnnidPort4EFEErrorWindowRemoteA | read-write | current | NID Series card Port4 Link Event Configuration: Error Frame Event - Error Window |
| 1.3.6.1.4.1.4756.20.501.20.1.417 | ColumnnidPort4EFEErrorThresholdRemoteA | read-write | current | NID Series card Port4 Link Event Configuration: Error Frame Event - Error Threshold |
| 1.3.6.1.4.1.4756.20.501.20.1.418 | ColumnnidPort4SPEEErrorWindowRemoteA | read-write | current | NID Series card Port4 Link Event Configuration: Symbol Period Error Event - Error Window |
| 1.3.6.1.4.1.4756.20.501.20.1.419 | ColumnnidPort4SPEEErrorThresholdRemoteA | read-write | current | NID Series card Port4 Link Event Configuration: Symbol Period Error Event - Error Threshold |
| 1.3.6.1.4.1.4756.20.501.20.1.420 | ColumnnidPort4SSEErrorWindowRemoteA | read-write | current | NID Series card Port4 Link Event Configuration: Seconds Summary Event - Error Window |
| 1.3.6.1.4.1.4756.20.501.20.1.421 | ColumnnidPort4SSEErrorThresholdRemoteA | read-write | current | NID Series card Port4 Link Event Configuration: Seconds Summary Event - Error Threshold |
| 1.3.6.1.4.1.4756.20.501.20.1.422 | ColumnnidPort5EFEErrorWindowRemoteA | read-write | current | NID Series card Port5 Link Event Configuration: Error Frame Event - Error Window |
| 1.3.6.1.4.1.4756.20.501.20.1.423 | ColumnnidPort5EFEErrorThresholdRemoteA | read-write | current | NID Series card Port5 Link Event Configuration: Error Frame Event - Error Threshold |
| 1.3.6.1.4.1.4756.20.501.20.1.424 | ColumnnidPort5SPEEErrorWindowRemoteA | read-write | current | NID Series card Port5 Link Event Configuration: Symbol Period Error Event - Error Window |
| 1.3.6.1.4.1.4756.20.501.20.1.425 | ColumnnidPort5SPEEErrorThresholdRemoteA | read-write | current | NID Series card Port5 Link Event Configuration: Symbol Period Error Event - Error Threshold |
| 1.3.6.1.4.1.4756.20.501.20.1.426 | ColumnnidPort5SSEErrorWindowRemoteA | read-write | current | NID Series card Port5 Link Event Configuration: Seconds Summary Event - Error Window |
| 1.3.6.1.4.1.4756.20.501.20.1.427 | ColumnnidPort5SSEErrorThresholdRemoteA | read-write | current | NID Series card Port5 Link Event Configuration: Seconds Summary Event - Error Threshold |
| 1.3.6.1.4.1.4756.20.501.20.1.428 | ColumnnidPort6EFEErrorWindowRemoteA | read-write | current | NID Series card Port6 Link Event Configuration: Error Frame Event - Error Window |
| 1.3.6.1.4.1.4756.20.501.20.1.429 | ColumnnidPort6EFEErrorThresholdRemoteA | read-write | current | NID Series card Port6 Link Event Configuration: Error Frame Event - Error Threshold |
| 1.3.6.1.4.1.4756.20.501.20.1.430 | ColumnnidPort6SPEEErrorWindowRemoteA | read-write | current | NID Series card Port6 Link Event Configuration: Symbol Period Error Event - Error Window |
| 1.3.6.1.4.1.4756.20.501.20.1.431 | ColumnnidPort6SPEEErrorThresholdRemoteA | read-write | current | NID Series card Port6 Link Event Configuration: Symbol Period Error Event - Error Threshold |
| 1.3.6.1.4.1.4756.20.501.20.1.432 | ColumnnidPort6SSEErrorWindowRemoteA | read-write | current | NID Series card Port6 Link Event Configuration: Seconds Summary Event - Error Window |
| 1.3.6.1.4.1.4756.20.501.20.1.433 | ColumnnidPort6SSEErrorThresholdRemoteA | read-write | current | NID Series card Port6 Link Event Configuration: Seconds Summary Event - Error Threshold |
| 1.3.6.1.4.1.4756.20.501.20.1.434 | ColumnnidPort7EFEErrorWindowRemoteA | read-write | current | NID Series card Port7 Link Event Configuration: Error Frame Event - Error Window |
| 1.3.6.1.4.1.4756.20.501.20.1.435 | ColumnnidPort7EFEErrorThresholdRemoteA | read-write | current | NID Series card Port7 Link Event Configuration: Error Frame Event - Error Threshold |
| 1.3.6.1.4.1.4756.20.501.20.1.436 | ColumnnidPort7SPEEErrorWindowRemoteA | read-write | current | NID Series card Port7 Link Event Configuration: Symbol Period Error Event - Error Window |
| 1.3.6.1.4.1.4756.20.501.20.1.437 | ColumnnidPort7SPEEErrorThresholdRemoteA | read-write | current | NID Series card Port7 Link Event Configuration: Symbol Period Error Event - Error Threshold |
| 1.3.6.1.4.1.4756.20.501.20.1.438 | ColumnnidPort7SSEErrorWindowRemoteA | read-write | current | NID Series card Port7 Link Event Configuration: Seconds Summary Event - Error Window |
| 1.3.6.1.4.1.4756.20.501.20.1.439 | ColumnnidPort7SSEErrorThresholdRemoteA | read-write | current | NID Series card Port7 Link Event Configuration: Seconds Summary Event - Error Threshold |
| 1.3.6.1.4.1.4756.20.501.20.1.440 | ColumnnidPort8EFEErrorWindowRemoteA | read-write | current | NID Series card Port8 Link Event Configuration: Error Frame Event - Error Window |
| 1.3.6.1.4.1.4756.20.501.20.1.441 | ColumnnidPort8EFEErrorThresholdRemoteA | read-write | current | NID Series card Port8 Link Event Configuration: Error Frame Event - Error Threshold |
| 1.3.6.1.4.1.4756.20.501.20.1.442 | ColumnnidPort8SPEEErrorWindowRemoteA | read-write | current | NID Series card Port8 Link Event Configuration: Symbol Period Error Event - Error Window |
| 1.3.6.1.4.1.4756.20.501.20.1.443 | ColumnnidPort8SPEEErrorThresholdRemoteA | read-write | current | NID Series card Port8 Link Event Configuration: Symbol Period Error Event - Error Threshold |
| 1.3.6.1.4.1.4756.20.501.20.1.444 | ColumnnidPort8SSEErrorWindowRemoteA | read-write | current | NID Series card Port8 Link Event Configuration: Seconds Summary Event - Error Window |
| 1.3.6.1.4.1.4756.20.501.20.1.445 | ColumnnidPort8SSEErrorThresholdRemoteA | read-write | current | NID Series card Port8 Link Event Configuration: Seconds Summary Event - Error Threshold |
| 1.3.6.1.4.1.4756.20.501.20.1.446 | ColumnnidPort1RxOAMInfoPDURemoteA | read-only | current | NID Series card Port1 Detailed Link OAM Statistics: Rx OAM Information PDU's |
| 1.3.6.1.4.1.4756.20.501.20.1.447 | ColumnnidPort1RxUniqueErrorEventRemoteA | read-only | current | NID Series card Port1 Detailed Link OAM Statistics: Rx Unique Error Event Notificatio |
| 1.3.6.1.4.1.4756.20.501.20.1.448 | ColumnnidPort1RxDuplicateErrorEventRemoteA | read-only | current | NID Series card Port1 Detailed Link OAM Statistics: Rx Duplicate Error Event Notification |
| 1.3.6.1.4.1.4756.20.501.20.1.449 | ColumnnidPort1RxLoopBackControlRemoteA | read-only | current | NID Series card Port1 Detailed Link OAM Statistics: Rx Loopback Control |
| 1.3.6.1.4.1.4756.20.501.20.1.450 | ColumnnidPort1RxVariableRequestRemoteA | read-only | current | NID Series card Port1 Detailed Link OAM Statistics: Rx Variable Request |
| 1.3.6.1.4.1.4756.20.501.20.1.451 | ColumnnidPort1RxVariableResponseRemoteA | read-only | current | NID Series card Port1 Detailed Link OAM Statistics: Rx Variable Response |
| 1.3.6.1.4.1.4756.20.501.20.1.452 | ColumnnidPort1RxOrgSpecificPDURemoteA | read-only | current | NID Series card Port1 Detailed Link OAM Statistics: Rx Org Specific PDU's |
| 1.3.6.1.4.1.4756.20.501.20.1.453 | ColumnnidPort1RxUnsupportedCodesRemoteA | read-only | current | NID Series card Port1 Detailed Link OAM Statistics: Rx Unsupported Codes |
| 1.3.6.1.4.1.4756.20.501.20.1.454 | ColumnnidPort1RxLinkFaultPDURemoteA | read-only | current | NID Series card Port1 Detailed Link OAM Statistics: Rx Link Fault PDU's |
| 1.3.6.1.4.1.4756.20.501.20.1.455 | ColumnnidPort1RxDyingGaspRemoteA | read-only | current | NID Series card Port1 Detailed Link OAM Statistics: Rx Dying Gasp |
| 1.3.6.1.4.1.4756.20.501.20.1.456 | ColumnnidPort1RxCriticalEventPDURemoteA | read-only | current | NID Series card Port1 Detailed Link OAM Statistics: Rx Dying Gasp |
| 1.3.6.1.4.1.4756.20.501.20.1.457 | ColumnnidPort1TxOAMInfoPDURemoteA | read-only | current | NID Series card Port1 Detailed Link OAM Statistics: Tx OAM Information PDU's |
| 1.3.6.1.4.1.4756.20.501.20.1.458 | ColumnnidPort1TxUniqueErrorEventRemoteA | read-only | current | NID Series card Port1 Detailed Link OAM Statistics: Tx Unique Error Event Notificatio |
| 1.3.6.1.4.1.4756.20.501.20.1.459 | ColumnnidPort1TxDuplicateErrorEventRemoteA | read-only | current | NID Series card Port1 Detailed Link OAM Statistics: Tx Duplicate Error Event Notification |
| 1.3.6.1.4.1.4756.20.501.20.1.460 | ColumnnidPort1TxLoopBackControlRemoteA | read-only | current | NID Series card Port1 Detailed Link OAM Statistics: Tx Loopback Control |
| 1.3.6.1.4.1.4756.20.501.20.1.461 | ColumnnidPort1TxVariableRequestRemoteA | read-only | current | NID Series card Port1 Detailed Link OAM Statistics: Tx Variable Request |
| 1.3.6.1.4.1.4756.20.501.20.1.462 | ColumnnidPort1TxVariableResponseRemoteA | read-only | current | NID Series card Port1 Detailed Link OAM Statistics: Tx Variable Response |
| 1.3.6.1.4.1.4756.20.501.20.1.463 | ColumnnidPort1TxOrgSpecificPDURemoteA | read-only | current | NID Series card Port1 Detailed Link OAM Statistics: Tx Org Specific PDU's |
| 1.3.6.1.4.1.4756.20.501.20.1.464 | ColumnnidPort1TxUnsupportedCodesRemoteA | read-only | current | NID Series card Port1 Detailed Link OAM Statistics: Tx Unsupported Codes |
| 1.3.6.1.4.1.4756.20.501.20.1.465 | ColumnnidPort1TxLinkFaultPDURemoteA | read-only | current | NID Series card Port1 Detailed Link OAM Statistics: Tx Link Fault PDU's |
| 1.3.6.1.4.1.4756.20.501.20.1.466 | ColumnnidPort1TxDyingGaspRemoteA | read-only | current | NID Series card Port1 Detailed Link OAM Statistics: Tx Dying Gasp |
| 1.3.6.1.4.1.4756.20.501.20.1.467 | ColumnnidPort1TxCriticalEventPDURemoteA | read-only | current | NID Series card Port1 Detailed Link OAM Statistics: Tx Dying Gasp |
| 1.3.6.1.4.1.4756.20.501.20.1.468 | ColumnnidPort2RxOAMInfoPDURemoteA | read-only | current | NID Series card Port2 Detailed Link OAM Statistics: Rx OAM Information PDU's |
| 1.3.6.1.4.1.4756.20.501.20.1.469 | ColumnnidPort2RxUniqueErrorEventRemoteA | read-only | current | NID Series card Port2 Detailed Link OAM Statistics: Rx Unique Error Event Notificatio |
| 1.3.6.1.4.1.4756.20.501.20.1.470 | ColumnnidPort2RxDuplicateErrorEventRemoteA | read-only | current | NID Series card Port2 Detailed Link OAM Statistics: Rx Duplicate Error Event Notification |
| 1.3.6.1.4.1.4756.20.501.20.1.471 | ColumnnidPort2RxLoopBackControlRemoteA | read-only | current | NID Series card Port2 Detailed Link OAM Statistics: Rx Loopback Control |
| 1.3.6.1.4.1.4756.20.501.20.1.472 | ColumnnidPort2RxVariableRequestRemoteA | read-only | current | NID Series card Port2 Detailed Link OAM Statistics: Rx Variable Request |
| 1.3.6.1.4.1.4756.20.501.20.1.473 | ColumnnidPort2RxVariableResponseRemoteA | read-only | current | NID Series card Port2 Detailed Link OAM Statistics: Rx Variable Response |
| 1.3.6.1.4.1.4756.20.501.20.1.474 | ColumnnidPort2RxOrgSpecificPDURemoteA | read-only | current | NID Series card Port2 Detailed Link OAM Statistics: Rx Org Specific PDU's |
| 1.3.6.1.4.1.4756.20.501.20.1.475 | ColumnnidPort2RxUnsupportedCodesRemoteA | read-only | current | NID Series card Port2 Detailed Link OAM Statistics: Rx Unsupported Codes |
| 1.3.6.1.4.1.4756.20.501.20.1.476 | ColumnnidPort2RxLinkFaultPDURemoteA | read-only | current | NID Series card Port2 Detailed Link OAM Statistics: Rx Link Fault PDU's |
| 1.3.6.1.4.1.4756.20.501.20.1.477 | ColumnnidPort2RxDyingGaspRemoteA | read-only | current | NID Series card Port2 Detailed Link OAM Statistics: Rx Dying Gasp |
| 1.3.6.1.4.1.4756.20.501.20.1.478 | ColumnnidPort2RxCriticalEventPDURemoteA | read-only | current | NID Series card Port2 Detailed Link OAM Statistics: Rx Dying Gasp |
| 1.3.6.1.4.1.4756.20.501.20.1.479 | ColumnnidPort2TxOAMInfoPDURemoteA | read-only | current | NID Series card Port2 Detailed Link OAM Statistics: Tx OAM Information PDU's |
| 1.3.6.1.4.1.4756.20.501.20.1.480 | ColumnnidPort2TxUniqueErrorEventRemoteA | read-only | current | NID Series card Port2 Detailed Link OAM Statistics: Tx Unique Error Event Notificatio |
| 1.3.6.1.4.1.4756.20.501.20.1.481 | ColumnnidPort2TxDuplicateErrorEventRemoteA | read-only | current | NID Series card Port2 Detailed Link OAM Statistics: Tx Duplicate Error Event Notification |
| 1.3.6.1.4.1.4756.20.501.20.1.482 | ColumnnidPort2TxLoopBackControlRemoteA | read-only | current | NID Series card Port2 Detailed Link OAM Statistics: Tx Loopback Control |
| 1.3.6.1.4.1.4756.20.501.20.1.483 | ColumnnidPort2TxVariableRequestRemoteA | read-only | current | NID Series card Port2 Detailed Link OAM Statistics: Tx Variable Request |
| 1.3.6.1.4.1.4756.20.501.20.1.484 | ColumnnidPort2TxVariableResponseRemoteA | read-only | current | NID Series card Port2 Detailed Link OAM Statistics: Tx Variable Response |
| 1.3.6.1.4.1.4756.20.501.20.1.485 | ColumnnidPort2TxOrgSpecificPDURemoteA | read-only | current | NID Series card Port2 Detailed Link OAM Statistics: Tx Org Specific PDU's |
| 1.3.6.1.4.1.4756.20.501.20.1.486 | ColumnnidPort2TxUnsupportedCodesRemoteA | read-only | current | NID Series card Port2 Detailed Link OAM Statistics: Tx Unsupported Codes |
| 1.3.6.1.4.1.4756.20.501.20.1.487 | ColumnnidPort2TxLinkFaultPDURemoteA | read-only | current | NID Series card Port2 Detailed Link OAM Statistics: Tx Link Fault PDU's |
| 1.3.6.1.4.1.4756.20.501.20.1.488 | ColumnnidPort2TxDyingGaspRemoteA | read-only | current | NID Series card Port2 Detailed Link OAM Statistics: Tx Dying Gasp |
| 1.3.6.1.4.1.4756.20.501.20.1.489 | ColumnnidPort2TxCriticalEventPDURemoteA | read-only | current | NID Series card Port2 Detailed Link OAM Statistics: Tx Dying Gasp |
| 1.3.6.1.4.1.4756.20.501.20.1.490 | ColumnnidPort3RxOAMInfoPDURemoteA | read-only | current | NID Series card Port3 Detailed Link OAM Statistics: Rx OAM Information PDU's |
| 1.3.6.1.4.1.4756.20.501.20.1.491 | ColumnnidPort3RxUniqueErrorEventRemoteA | read-only | current | NID Series card Port3 Detailed Link OAM Statistics: Rx Unique Error Event Notificatio |
| 1.3.6.1.4.1.4756.20.501.20.1.492 | ColumnnidPort3RxDuplicateErrorEventRemoteA | read-only | current | NID Series card Port3 Detailed Link OAM Statistics: Rx Duplicate Error Event Notification |
| 1.3.6.1.4.1.4756.20.501.20.1.493 | ColumnnidPort3RxLoopBackControlRemoteA | read-only | current | NID Series card Port3 Detailed Link OAM Statistics: Rx Loopback Control |
| 1.3.6.1.4.1.4756.20.501.20.1.494 | ColumnnidPort3RxVariableRequestRemoteA | read-only | current | NID Series card Port3 Detailed Link OAM Statistics: Rx Variable Request |
| 1.3.6.1.4.1.4756.20.501.20.1.495 | ColumnnidPort3RxVariableResponseRemoteA | read-only | current | NID Series card Port3 Detailed Link OAM Statistics: Rx Variable Response |
| 1.3.6.1.4.1.4756.20.501.20.1.496 | ColumnnidPort3RxOrgSpecificPDURemoteA | read-only | current | NID Series card Port3 Detailed Link OAM Statistics: Rx Org Specific PDU's |
| 1.3.6.1.4.1.4756.20.501.20.1.497 | ColumnnidPort3RxUnsupportedCodesRemoteA | read-only | current | NID Series card Port3 Detailed Link OAM Statistics: Rx Unsupported Codes |
| 1.3.6.1.4.1.4756.20.501.20.1.498 | ColumnnidPort3RxLinkFaultPDURemoteA | read-only | current | NID Series card Port3 Detailed Link OAM Statistics: Rx Link Fault PDU's |
| 1.3.6.1.4.1.4756.20.501.20.1.499 | ColumnnidPort3RxDyingGaspRemoteA | read-only | current | NID Series card Port3 Detailed Link OAM Statistics: Rx Dying Gasp |
| 1.3.6.1.4.1.4756.20.501.20.1.500 | ColumnnidPort3RxCriticalEventPDURemoteA | read-only | current | NID Series card Port3 Detailed Link OAM Statistics: Rx Dying Gasp |
| 1.3.6.1.4.1.4756.20.501.20.1.501 | ColumnnidPort3TxOAMInfoPDURemoteA | read-only | current | NID Series card Port3 Detailed Link OAM Statistics: Tx OAM Information PDU's |
| 1.3.6.1.4.1.4756.20.501.20.1.502 | ColumnnidPort3TxUniqueErrorEventRemoteA | read-only | current | NID Series card Port3 Detailed Link OAM Statistics: Tx Unique Error Event Notificatio |
| 1.3.6.1.4.1.4756.20.501.20.1.503 | ColumnnidPort3TxDuplicateErrorEventRemoteA | read-only | current | NID Series card Port3 Detailed Link OAM Statistics: Tx Duplicate Error Event Notification |
| 1.3.6.1.4.1.4756.20.501.20.1.504 | ColumnnidPort3TxLoopBackControlRemoteA | read-only | current | NID Series card Port3 Detailed Link OAM Statistics: Tx Loopback Control |
| 1.3.6.1.4.1.4756.20.501.20.1.505 | ColumnnidPort3TxVariableRequestRemoteA | read-only | current | NID Series card Port3 Detailed Link OAM Statistics: Tx Variable Request |
| 1.3.6.1.4.1.4756.20.501.20.1.506 | ColumnnidPort3TxVariableResponseRemoteA | read-only | current | NID Series card Port3 Detailed Link OAM Statistics: Tx Variable Response |
| 1.3.6.1.4.1.4756.20.501.20.1.507 | ColumnnidPort3TxOrgSpecificPDURemoteA | read-only | current | NID Series card Port3 Detailed Link OAM Statistics: Tx Org Specific PDU's |
| 1.3.6.1.4.1.4756.20.501.20.1.508 | ColumnnidPort3TxUnsupportedCodesRemoteA | read-only | current | NID Series card Port3 Detailed Link OAM Statistics: Tx Unsupported Codes |
| 1.3.6.1.4.1.4756.20.501.20.1.509 | ColumnnidPort3TxLinkFaultPDURemoteA | read-only | current | NID Series card Port3 Detailed Link OAM Statistics: Tx Link Fault PDU's |
| 1.3.6.1.4.1.4756.20.501.20.1.510 | ColumnnidPort3TxDyingGaspRemoteA | read-only | current | NID Series card Port3 Detailed Link OAM Statistics: Tx Dying Gasp |
| 1.3.6.1.4.1.4756.20.501.20.1.511 | ColumnnidPort3TxCriticalEventPDURemoteA | read-only | current | NID Series card Port3 Detailed Link OAM Statistics: Tx Dying Gasp |
| 1.3.6.1.4.1.4756.20.501.20.1.512 | ColumnnidPort4RxOAMInfoPDURemoteA | read-only | current | NID Series card Port4 Detailed Link OAM Statistics: Rx OAM Information PDU's |
| 1.3.6.1.4.1.4756.20.501.20.1.513 | ColumnnidPort4RxUniqueErrorEventRemoteA | read-only | current | NID Series card Port4 Detailed Link OAM Statistics: Rx Unique Error Event Notificatio |
| 1.3.6.1.4.1.4756.20.501.20.1.514 | ColumnnidPort4RxDuplicateErrorEventRemoteA | read-only | current | NID Series card Port4 Detailed Link OAM Statistics: Rx Duplicate Error Event Notification |
| 1.3.6.1.4.1.4756.20.501.20.1.515 | ColumnnidPort4RxLoopBackControlRemoteA | read-only | current | NID Series card Port4 Detailed Link OAM Statistics: Rx Loopback Control |
| 1.3.6.1.4.1.4756.20.501.20.1.516 | ColumnnidPort4RxVariableRequestRemoteA | read-only | current | NID Series card Port4 Detailed Link OAM Statistics: Rx Variable Request |
| 1.3.6.1.4.1.4756.20.501.20.1.517 | ColumnnidPort4RxVariableResponseRemoteA | read-only | current | NID Series card Port4 Detailed Link OAM Statistics: Rx Variable Response |
| 1.3.6.1.4.1.4756.20.501.20.1.518 | ColumnnidPort4RxOrgSpecificPDURemoteA | read-only | current | NID Series card Port4 Detailed Link OAM Statistics: Rx Org Specific PDU's |
| 1.3.6.1.4.1.4756.20.501.20.1.519 | ColumnnidPort4RxUnsupportedCodesRemoteA | read-only | current | NID Series card Port4 Detailed Link OAM Statistics: Rx Unsupported Codes |
| 1.3.6.1.4.1.4756.20.501.20.1.520 | ColumnnidPort4RxLinkFaultPDURemoteA | read-only | current | NID Series card Port4 Detailed Link OAM Statistics: Rx Link Fault PDU's |
| 1.3.6.1.4.1.4756.20.501.20.1.521 | ColumnnidPort4RxDyingGaspRemoteA | read-only | current | NID Series card Port4 Detailed Link OAM Statistics: Rx Dying Gasp |
| 1.3.6.1.4.1.4756.20.501.20.1.522 | ColumnnidPort4RxCriticalEventPDURemoteA | read-only | current | NID Series card Port4 Detailed Link OAM Statistics: Rx Dying Gasp |
| 1.3.6.1.4.1.4756.20.501.20.1.523 | ColumnnidPort4TxOAMInfoPDURemoteA | read-only | current | NID Series card Port4 Detailed Link OAM Statistics: Tx OAM Information PDU's |
| 1.3.6.1.4.1.4756.20.501.20.1.524 | ColumnnidPort4TxUniqueErrorEventRemoteA | read-only | current | NID Series card Port4 Detailed Link OAM Statistics: Tx Unique Error Event Notificatio |
| 1.3.6.1.4.1.4756.20.501.20.1.525 | ColumnnidPort4TxDuplicateErrorEventRemoteA | read-only | current | NID Series card Port4 Detailed Link OAM Statistics: Tx Duplicate Error Event Notification |
| 1.3.6.1.4.1.4756.20.501.20.1.526 | ColumnnidPort4TxLoopBackControlRemoteA | read-only | current | NID Series card Port4 Detailed Link OAM Statistics: Tx Loopback Control |
| 1.3.6.1.4.1.4756.20.501.20.1.527 | ColumnnidPort4TxVariableRequestRemoteA | read-only | current | NID Series card Port4 Detailed Link OAM Statistics: Tx Variable Request |
| 1.3.6.1.4.1.4756.20.501.20.1.528 | ColumnnidPort4TxVariableResponseRemoteA | read-only | current | NID Series card Port4 Detailed Link OAM Statistics: Tx Variable Response |
| 1.3.6.1.4.1.4756.20.501.20.1.529 | ColumnnidPort4TxOrgSpecificPDURemoteA | read-only | current | NID Series card Port4 Detailed Link OAM Statistics: Tx Org Specific PDU's |
| 1.3.6.1.4.1.4756.20.501.20.1.530 | ColumnnidPort4TxUnsupportedCodesRemoteA | read-only | current | NID Series card Port4 Detailed Link OAM Statistics: Tx Unsupported Codes |
| 1.3.6.1.4.1.4756.20.501.20.1.531 | ColumnnidPort4TxLinkFaultPDURemoteA | read-only | current | NID Series card Port4 Detailed Link OAM Statistics: Tx Link Fault PDU's |
| 1.3.6.1.4.1.4756.20.501.20.1.532 | ColumnnidPort4TxDyingGaspRemoteA | read-only | current | NID Series card Port4 Detailed Link OAM Statistics: Tx Dying Gasp |
| 1.3.6.1.4.1.4756.20.501.20.1.533 | ColumnnidPort4TxCriticalEventPDURemoteA | read-only | current | NID Series card Port4 Detailed Link OAM Statistics: Tx Dying Gasp |
| 1.3.6.1.4.1.4756.20.501.20.1.534 | ColumnnidPort5RxOAMInfoPDURemoteA | read-only | current | NID Series card Port5 Detailed Link OAM Statistics: Rx OAM Information PDU's |
| 1.3.6.1.4.1.4756.20.501.20.1.535 | ColumnnidPort5RxUniqueErrorEventRemoteA | read-only | current | NID Series card Port5 Detailed Link OAM Statistics: Rx Unique Error Event Notificatio |
| 1.3.6.1.4.1.4756.20.501.20.1.536 | ColumnnidPort5RxDuplicateErrorEventRemoteA | read-only | current | NID Series card Port5 Detailed Link OAM Statistics: Rx Duplicate Error Event Notification |
| 1.3.6.1.4.1.4756.20.501.20.1.537 | ColumnnidPort5RxLoopBackControlRemoteA | read-only | current | NID Series card Port5 Detailed Link OAM Statistics: Rx Loopback Control |
| 1.3.6.1.4.1.4756.20.501.20.1.538 | ColumnnidPort5RxVariableRequestRemoteA | read-only | current | NID Series card Port5 Detailed Link OAM Statistics: Rx Variable Request |
| 1.3.6.1.4.1.4756.20.501.20.1.539 | ColumnnidPort5RxVariableResponseRemoteA | read-only | current | NID Series card Port5 Detailed Link OAM Statistics: Rx Variable Response |
| 1.3.6.1.4.1.4756.20.501.20.1.540 | ColumnnidPort5RxOrgSpecificPDURemoteA | read-only | current | NID Series card Port5 Detailed Link OAM Statistics: Rx Org Specific PDU's |
| 1.3.6.1.4.1.4756.20.501.20.1.541 | ColumnnidPort5RxUnsupportedCodesRemoteA | read-only | current | NID Series card Port5 Detailed Link OAM Statistics: Rx Unsupported Codes |
| 1.3.6.1.4.1.4756.20.501.20.1.542 | ColumnnidPort5RxLinkFaultPDURemoteA | read-only | current | NID Series card Port5 Detailed Link OAM Statistics: Rx Link Fault PDU's |
| 1.3.6.1.4.1.4756.20.501.20.1.543 | ColumnnidPort5RxDyingGaspRemoteA | read-only | current | NID Series card Port5 Detailed Link OAM Statistics: Rx Dying Gasp |
| 1.3.6.1.4.1.4756.20.501.20.1.544 | ColumnnidPort5RxCriticalEventPDURemoteA | read-only | current | NID Series card Port5 Detailed Link OAM Statistics: Rx Dying Gasp |
| 1.3.6.1.4.1.4756.20.501.20.1.545 | ColumnnidPort5TxOAMInfoPDURemoteA | read-only | current | NID Series card Port5 Detailed Link OAM Statistics: Tx OAM Information PDU's |
| 1.3.6.1.4.1.4756.20.501.20.1.546 | ColumnnidPort5TxUniqueErrorEventRemoteA | read-only | current | NID Series card Port5 Detailed Link OAM Statistics: Tx Unique Error Event Notificatio |
| 1.3.6.1.4.1.4756.20.501.20.1.547 | ColumnnidPort5TxDuplicateErrorEventRemoteA | read-only | current | NID Series card Port5 Detailed Link OAM Statistics: Tx Duplicate Error Event Notification |
| 1.3.6.1.4.1.4756.20.501.20.1.548 | ColumnnidPort5TxLoopBackControlRemoteA | read-only | current | NID Series card Port5 Detailed Link OAM Statistics: Tx Loopback Control |
| 1.3.6.1.4.1.4756.20.501.20.1.549 | ColumnnidPort5TxVariableRequestRemoteA | read-only | current | NID Series card Port5 Detailed Link OAM Statistics: Tx Variable Request |
| 1.3.6.1.4.1.4756.20.501.20.1.550 | ColumnnidPort5TxVariableResponseRemoteA | read-only | current | NID Series card Port5 Detailed Link OAM Statistics: Tx Variable Response |
| 1.3.6.1.4.1.4756.20.501.20.1.551 | ColumnnidPort5TxOrgSpecificPDURemoteA | read-only | current | NID Series card Port5 Detailed Link OAM Statistics: Tx Org Specific PDU's |
| 1.3.6.1.4.1.4756.20.501.20.1.552 | ColumnnidPort5TxUnsupportedCodesRemoteA | read-only | current | NID Series card Port5 Detailed Link OAM Statistics: Tx Unsupported Codes |
| 1.3.6.1.4.1.4756.20.501.20.1.553 | ColumnnidPort5TxLinkFaultPDURemoteA | read-only | current | NID Series card Port5 Detailed Link OAM Statistics: Tx Link Fault PDU's |
| 1.3.6.1.4.1.4756.20.501.20.1.554 | ColumnnidPort5TxDyingGaspRemoteA | read-only | current | NID Series card Port5 Detailed Link OAM Statistics: Tx Dying Gasp |
| 1.3.6.1.4.1.4756.20.501.20.1.555 | ColumnnidPort5TxCriticalEventPDURemoteA | read-only | current | NID Series card Port5 Detailed Link OAM Statistics: Tx Dying Gasp |
| 1.3.6.1.4.1.4756.20.501.20.1.556 | ColumnnidPort6RxOAMInfoPDURemoteA | read-only | current | NID Series card Port6 Detailed Link OAM Statistics: Rx OAM Information PDU's |
| 1.3.6.1.4.1.4756.20.501.20.1.557 | ColumnnidPort6RxUniqueErrorEventRemoteA | read-only | current | NID Series card Port6 Detailed Link OAM Statistics: Rx Unique Error Event Notificatio |
| 1.3.6.1.4.1.4756.20.501.20.1.558 | ColumnnidPort6RxDuplicateErrorEventRemoteA | read-only | current | NID Series card Port6 Detailed Link OAM Statistics: Rx Duplicate Error Event Notification |
| 1.3.6.1.4.1.4756.20.501.20.1.559 | ColumnnidPort6RxLoopBackControlRemoteA | read-only | current | NID Series card Port6 Detailed Link OAM Statistics: Rx Loopback Control |
| 1.3.6.1.4.1.4756.20.501.20.1.560 | ColumnnidPort6RxVariableRequestRemoteA | read-only | current | NID Series card Port6 Detailed Link OAM Statistics: Rx Variable Request |
| 1.3.6.1.4.1.4756.20.501.20.1.561 | ColumnnidPort6RxVariableResponseRemoteA | read-only | current | NID Series card Port6 Detailed Link OAM Statistics: Rx Variable Response |
| 1.3.6.1.4.1.4756.20.501.20.1.562 | ColumnnidPort6RxOrgSpecificPDURemoteA | read-only | current | NID Series card Port6 Detailed Link OAM Statistics: Rx Org Specific PDU's |
| 1.3.6.1.4.1.4756.20.501.20.1.563 | ColumnnidPort6RxUnsupportedCodesRemoteA | read-only | current | NID Series card Port6 Detailed Link OAM Statistics: Rx Unsupported Codes |
| 1.3.6.1.4.1.4756.20.501.20.1.564 | ColumnnidPort6RxLinkFaultPDURemoteA | read-only | current | NID Series card Port6 Detailed Link OAM Statistics: Rx Link Fault PDU's |
| 1.3.6.1.4.1.4756.20.501.20.1.565 | ColumnnidPort6RxDyingGaspRemoteA | read-only | current | NID Series card Port6 Detailed Link OAM Statistics: Rx Dying Gasp |
| 1.3.6.1.4.1.4756.20.501.20.1.566 | ColumnnidPort6RxCriticalEventPDURemoteA | read-only | current | NID Series card Port6 Detailed Link OAM Statistics: Rx Dying Gasp |
| 1.3.6.1.4.1.4756.20.501.20.1.567 | ColumnnidPort6TxOAMInfoPDURemoteA | read-only | current | NID Series card Port6 Detailed Link OAM Statistics: Tx OAM Information PDU's |
| 1.3.6.1.4.1.4756.20.501.20.1.568 | ColumnnidPort6TxUniqueErrorEventRemoteA | read-only | current | NID Series card Port6 Detailed Link OAM Statistics: Tx Unique Error Event Notificatio |
| 1.3.6.1.4.1.4756.20.501.20.1.569 | ColumnnidPort6TxDuplicateErrorEventRemoteA | read-only | current | NID Series card Port6 Detailed Link OAM Statistics: Tx Duplicate Error Event Notification |
| 1.3.6.1.4.1.4756.20.501.20.1.570 | ColumnnidPort6TxLoopBackControlRemoteA | read-only | current | NID Series card Port6 Detailed Link OAM Statistics: Tx Loopback Control |
| 1.3.6.1.4.1.4756.20.501.20.1.571 | ColumnnidPort6TxVariableRequestRemoteA | read-only | current | NID Series card Port6 Detailed Link OAM Statistics: Tx Variable Request |
| 1.3.6.1.4.1.4756.20.501.20.1.572 | ColumnnidPort6TxVariableResponseRemoteA | read-only | current | NID Series card Port6 Detailed Link OAM Statistics: Tx Variable Response |
| 1.3.6.1.4.1.4756.20.501.20.1.573 | ColumnnidPort6TxOrgSpecificPDURemoteA | read-only | current | NID Series card Port6 Detailed Link OAM Statistics: Tx Org Specific PDU's |
| 1.3.6.1.4.1.4756.20.501.20.1.574 | ColumnnidPort6TxUnsupportedCodesRemoteA | read-only | current | NID Series card Port6 Detailed Link OAM Statistics: Tx Unsupported Codes |
| 1.3.6.1.4.1.4756.20.501.20.1.575 | ColumnnidPort6TxLinkFaultPDURemoteA | read-only | current | NID Series card Port6 Detailed Link OAM Statistics: Tx Link Fault PDU's |
| 1.3.6.1.4.1.4756.20.501.20.1.576 | ColumnnidPort6TxDyingGaspRemoteA | read-only | current | NID Series card Port6 Detailed Link OAM Statistics: Tx Dying Gasp |
| 1.3.6.1.4.1.4756.20.501.20.1.577 | ColumnnidPort6TxCriticalEventPDURemoteA | read-only | current | NID Series card Port6 Detailed Link OAM Statistics: Tx Dying Gasp |
| 1.3.6.1.4.1.4756.20.501.20.1.578 | ColumnnidPort7RxOAMInfoPDURemoteA | read-only | current | NID Series card Port7 Detailed Link OAM Statistics: Rx OAM Information PDU's |
| 1.3.6.1.4.1.4756.20.501.20.1.579 | ColumnnidPort7RxUniqueErrorEventRemoteA | read-only | current | NID Series card Port7 Detailed Link OAM Statistics: Rx Unique Error Event Notificatio |
| 1.3.6.1.4.1.4756.20.501.20.1.580 | ColumnnidPort7RxDuplicateErrorEventRemoteA | read-only | current | NID Series card Port7 Detailed Link OAM Statistics: Rx Duplicate Error Event Notification |
| 1.3.6.1.4.1.4756.20.501.20.1.581 | ColumnnidPort7RxLoopBackControlRemoteA | read-only | current | NID Series card Port7 Detailed Link OAM Statistics: Rx Loopback Control |
| 1.3.6.1.4.1.4756.20.501.20.1.582 | ColumnnidPort7RxVariableRequestRemoteA | read-only | current | NID Series card Port7 Detailed Link OAM Statistics: Rx Variable Request |
| 1.3.6.1.4.1.4756.20.501.20.1.583 | ColumnnidPort7RxVariableResponseRemoteA | read-only | current | NID Series card Port7 Detailed Link OAM Statistics: Rx Variable Response |
| 1.3.6.1.4.1.4756.20.501.20.1.584 | ColumnnidPort7RxOrgSpecificPDURemoteA | read-only | current | NID Series card Port7 Detailed Link OAM Statistics: Rx Org Specific PDU's |
| 1.3.6.1.4.1.4756.20.501.20.1.585 | ColumnnidPort7RxUnsupportedCodesRemoteA | read-only | current | NID Series card Port7 Detailed Link OAM Statistics: Rx Unsupported Codes |
| 1.3.6.1.4.1.4756.20.501.20.1.586 | ColumnnidPort7RxLinkFaultPDURemoteA | read-only | current | NID Series card Port7 Detailed Link OAM Statistics: Rx Link Fault PDU's |
| 1.3.6.1.4.1.4756.20.501.20.1.587 | ColumnnidPort7RxDyingGaspRemoteA | read-only | current | NID Series card Port7 Detailed Link OAM Statistics: Rx Dying Gasp |
| 1.3.6.1.4.1.4756.20.501.20.1.588 | ColumnnidPort7RxCriticalEventPDURemoteA | read-only | current | NID Series card Port7 Detailed Link OAM Statistics: Rx Dying Gasp |
| 1.3.6.1.4.1.4756.20.501.20.1.589 | ColumnnidPort7TxOAMInfoPDURemoteA | read-only | current | NID Series card Port7 Detailed Link OAM Statistics: Tx OAM Information PDU's |
| 1.3.6.1.4.1.4756.20.501.20.1.590 | ColumnnidPort7TxUniqueErrorEventRemoteA | read-only | current | NID Series card Port7 Detailed Link OAM Statistics: Tx Unique Error Event Notificatio |
| 1.3.6.1.4.1.4756.20.501.20.1.591 | ColumnnidPort7TxDuplicateErrorEventRemoteA | read-only | current | NID Series card Port7 Detailed Link OAM Statistics: Tx Duplicate Error Event Notification |
| 1.3.6.1.4.1.4756.20.501.20.1.592 | ColumnnidPort7TxLoopBackControlRemoteA | read-only | current | NID Series card Port7 Detailed Link OAM Statistics: Tx Loopback Control |
| 1.3.6.1.4.1.4756.20.501.20.1.593 | ColumnnidPort7TxVariableRequestRemoteA | read-only | current | NID Series card Port7 Detailed Link OAM Statistics: Tx Variable Request |
| 1.3.6.1.4.1.4756.20.501.20.1.594 | ColumnnidPort7TxVariableResponseRemoteA | read-only | current | NID Series card Port7 Detailed Link OAM Statistics: Tx Variable Response |
| 1.3.6.1.4.1.4756.20.501.20.1.595 | ColumnnidPort7TxOrgSpecificPDURemoteA | read-only | current | NID Series card Port7 Detailed Link OAM Statistics: Tx Org Specific PDU's |
| 1.3.6.1.4.1.4756.20.501.20.1.596 | ColumnnidPort7TxUnsupportedCodesRemoteA | read-only | current | NID Series card Port7 Detailed Link OAM Statistics: Tx Unsupported Codes |
| 1.3.6.1.4.1.4756.20.501.20.1.597 | ColumnnidPort7TxLinkFaultPDURemoteA | read-only | current | NID Series card Port7 Detailed Link OAM Statistics: Tx Link Fault PDU's |
| 1.3.6.1.4.1.4756.20.501.20.1.598 | ColumnnidPort7TxDyingGaspRemoteA | read-only | current | NID Series card Port7 Detailed Link OAM Statistics: Tx Dying Gasp |
| 1.3.6.1.4.1.4756.20.501.20.1.599 | ColumnnidPort7TxCriticalEventPDURemoteA | read-only | current | NID Series card Port7 Detailed Link OAM Statistics: Tx Dying Gasp |
| 1.3.6.1.4.1.4756.20.501.20.1.600 | ColumnnidPort8RxOAMInfoPDURemoteA | read-only | current | NID Series card Port8 Detailed Link OAM Statistics: Rx OAM Information PDU's |
| 1.3.6.1.4.1.4756.20.501.20.1.601 | ColumnnidPort8RxUniqueErrorEventRemoteA | read-only | current | NID Series card Port8 Detailed Link OAM Statistics: Rx Unique Error Event Notificatio |
| 1.3.6.1.4.1.4756.20.501.20.1.602 | ColumnnidPort8RxDuplicateErrorEventRemoteA | read-only | current | NID Series card Port8 Detailed Link OAM Statistics: Rx Duplicate Error Event Notification |
| 1.3.6.1.4.1.4756.20.501.20.1.603 | ColumnnidPort8RxLoopBackControlRemoteA | read-only | current | NID Series card Port8 Detailed Link OAM Statistics: Rx Loopback Control |
| 1.3.6.1.4.1.4756.20.501.20.1.604 | ColumnnidPort8RxVariableRequestRemoteA | read-only | current | NID Series card Port8 Detailed Link OAM Statistics: Rx Variable Request |
| 1.3.6.1.4.1.4756.20.501.20.1.605 | ColumnnidPort8RxVariableResponseRemoteA | read-only | current | NID Series card Port8 Detailed Link OAM Statistics: Rx Variable Response |
| 1.3.6.1.4.1.4756.20.501.20.1.606 | ColumnnidPort8RxOrgSpecificPDURemoteA | read-only | current | NID Series card Port8 Detailed Link OAM Statistics: Rx Org Specific PDU's |
| 1.3.6.1.4.1.4756.20.501.20.1.607 | ColumnnidPort8RxUnsupportedCodesRemoteA | read-only | current | NID Series card Port8 Detailed Link OAM Statistics: Rx Unsupported Codes |
| 1.3.6.1.4.1.4756.20.501.20.1.608 | ColumnnidPort8RxLinkFaultPDURemoteA | read-only | current | NID Series card Port8 Detailed Link OAM Statistics: Rx Link Fault PDU's |
| 1.3.6.1.4.1.4756.20.501.20.1.609 | ColumnnidPort8RxDyingGaspRemoteA | read-only | current | NID Series card Port8 Detailed Link OAM Statistics: Rx Dying Gasp |
| 1.3.6.1.4.1.4756.20.501.20.1.610 | ColumnnidPort8RxCriticalEventPDURemoteA | read-only | current | NID Series card Port8 Detailed Link OAM Statistics: Rx Dying Gasp |
| 1.3.6.1.4.1.4756.20.501.20.1.611 | ColumnnidPort8TxOAMInfoPDURemoteA | read-only | current | NID Series card Port8 Detailed Link OAM Statistics: Tx OAM Information PDU's |
| 1.3.6.1.4.1.4756.20.501.20.1.612 | ColumnnidPort8TxUniqueErrorEventRemoteA | read-only | current | NID Series card Port8 Detailed Link OAM Statistics: Tx Unique Error Event Notificatio |
| 1.3.6.1.4.1.4756.20.501.20.1.613 | ColumnnidPort8TxDuplicateErrorEventRemoteA | read-only | current | NID Series card Port8 Detailed Link OAM Statistics: Tx Duplicate Error Event Notification |
| 1.3.6.1.4.1.4756.20.501.20.1.614 | ColumnnidPort8TxLoopBackControlRemoteA | read-only | current | NID Series card Port8 Detailed Link OAM Statistics: Tx Loopback Control |
| 1.3.6.1.4.1.4756.20.501.20.1.615 | ColumnnidPort8TxVariableRequestRemoteA | read-only | current | NID Series card Port8 Detailed Link OAM Statistics: Tx Variable Request |
| 1.3.6.1.4.1.4756.20.501.20.1.616 | ColumnnidPort8TxVariableResponseRemoteA | read-only | current | NID Series card Port8 Detailed Link OAM Statistics: Tx Variable Response |
| 1.3.6.1.4.1.4756.20.501.20.1.617 | ColumnnidPort8TxOrgSpecificPDURemoteA | read-only | current | NID Series card Port8 Detailed Link OAM Statistics: Tx Org Specific PDU's |
| 1.3.6.1.4.1.4756.20.501.20.1.618 | ColumnnidPort8TxUnsupportedCodesRemoteA | read-only | current | NID Series card Port8 Detailed Link OAM Statistics: Tx Unsupported Codes |
| 1.3.6.1.4.1.4756.20.501.20.1.619 | ColumnnidPort8TxLinkFaultPDURemoteA | read-only | current | NID Series card Port8 Detailed Link OAM Statistics: Tx Link Fault PDU's |
| 1.3.6.1.4.1.4756.20.501.20.1.620 | ColumnnidPort8TxDyingGaspRemoteA | read-only | current | NID Series card Port8 Detailed Link OAM Statistics: Tx Dying Gasp |
| 1.3.6.1.4.1.4756.20.501.20.1.621 | ColumnnidPort8TxCriticalEventPDURemoteA | read-only | current | NID Series card Port8 Detailed Link OAM Statistics: Tx Dying Gasp |
| 1.3.6.1.4.1.4756.20.501.20.1.622 | ColumnnidPort1PDUPermisionRemoteA | read-only | current | NID Series card Detailed Link OAM Status for Port 1: PDU Permission |
| 1.3.6.1.4.1.4756.20.501.20.1.623 | ColumnnidPort1DiscoveryStateRemoteA | read-only | current | NID Series card Detailed Link OAM Status for Port 1: Discovery State |
| 1.3.6.1.4.1.4756.20.501.20.1.624 | ColumnnidPort1PeerMACAddrRemoteA | read-only | current | NID Series card Detailed Link OAM Status for Port 1: Discovery State |
| 1.3.6.1.4.1.4756.20.501.20.1.625 | ColumnnidPort1RemoteAModeRemoteA | read-only | current | NID Series card Detailed Link OAM Status for Port 1: RemoteA: Mode |
| 1.3.6.1.4.1.4756.20.501.20.1.626 | ColumnnidPort1RemoteAUnOperationRemoteA | read-only | current | NID Series card Detailed Link OAM Status for Port 1: RemoteA: Unidirectional Operation Support |
| 1.3.6.1.4.1.4756.20.501.20.1.627 | ColumnnidPort1RemoteARemoteLbRemoteA | read-only | current | NID Series card Detailed Link OAM Status for Port 1: RemoteA: Remote Loopback Support |
| 1.3.6.1.4.1.4756.20.501.20.1.628 | ColumnnidPort1RemoteALMRemoteA | read-only | current | NID Series card Detailed Link OAM Status for Port 1: RemoteA: Link Monitoring Support |
| 1.3.6.1.4.1.4756.20.501.20.1.629 | ColumnnidPort1RemoteAMIBRetrievalRemoteA | read-only | current | NID Series card Detailed Link OAM Status for Port 1: RemoteA: MIB Retrieval Support |
| 1.3.6.1.4.1.4756.20.501.20.1.630 | ColumnnidPort1RemoteAMTUSizeRemoteA | read-only | current | NID Series card Detailed Link OAM Status for Port 1: RemoteA: MTU Size |
| 1.3.6.1.4.1.4756.20.501.20.1.631 | ColumnnidPort1RemoteAMultiStateRemoteA | read-only | current | NID Series card Detailed Link OAM Status for Port 1: RemoteA: Multiplexer State |
| 1.3.6.1.4.1.4756.20.501.20.1.632 | ColumnnidPort1RemoteAParserStateRemoteA | read-only | current | NID Series card Detailed Link OAM Status for Port 1: RemoteA: Multiplexer State |
| 1.3.6.1.4.1.4756.20.501.20.1.633 | ColumnnidPort1RemoteAOUIRemoteA | read-only | current | NID Series card Detailed Link OAM Status for Port 1: RemoteA: Organizational Unique Identification |
| 1.3.6.1.4.1.4756.20.501.20.1.634 | ColumnnidPort1RemoteAPDURevRemoteA | read-only | current | NID Series card Detailed Link OAM Status for Port 1: RemoteA: PDU Revision |
| 1.3.6.1.4.1.4756.20.501.20.1.635 | ColumnnidPort1PeerModeRemoteA | read-only | current | NID Series card Detailed Link OAM Status for Port 1: Peer: Mode |
| 1.3.6.1.4.1.4756.20.501.20.1.636 | ColumnnidPort1PeerUnOperationRemoteA | read-only | current | NID Series card Detailed Link OAM Status for Port 1: Peer: Unidirectional Operation Support |
| 1.3.6.1.4.1.4756.20.501.20.1.637 | ColumnnidPort1PeerRemoteLbRemoteA | read-only | current | NID Series card Detailed Link OAM Status for Port 1: Peer: Remote Loopback Support |
| 1.3.6.1.4.1.4756.20.501.20.1.638 | ColumnnidPort1PeerLMRemoteA | read-only | current | NID Series card Detailed Link OAM Status for Port 1: Peer: Link Monitoring Support |
| 1.3.6.1.4.1.4756.20.501.20.1.639 | ColumnnidPort1PeerMIBRetrievalRemoteA | read-only | current | NID Series card Detailed Link OAM Status for Port 1: Peer: MIB Retrieval Support |
| 1.3.6.1.4.1.4756.20.501.20.1.640 | ColumnnidPort1PeerMTUSizeRemoteA | read-only | current | NID Series card Detailed Link OAM Status for Port 1: Peer: MTU Size |
| 1.3.6.1.4.1.4756.20.501.20.1.641 | ColumnnidPort1PeerMultiStateRemoteA | read-only | current | NID Series card Detailed Link OAM Status for Port 1: Peer: Multiplexer State |
| 1.3.6.1.4.1.4756.20.501.20.1.642 | ColumnnidPort1PeerParserStateRemoteA | read-only | current | NID Series card Detailed Link OAM Status for Port 1: Peer: Multiplexer State |
| 1.3.6.1.4.1.4756.20.501.20.1.643 | ColumnnidPort1PeerOUIRemoteA | read-only | current | NID Series card Detailed Link OAM Status for Port 1: Peer: Organizational Unique Identification |
| 1.3.6.1.4.1.4756.20.501.20.1.644 | ColumnnidPort1PeerPDURevRemoteA | read-only | current | NID Series card Detailed Link OAM Status for Port 1: Peer: PDU Revision |
| 1.3.6.1.4.1.4756.20.501.20.1.645 | ColumnnidPort2PDUPermisionRemoteA | read-only | current | NID Series card Detailed Link OAM Status for Port 2: PDU Permission |
| 1.3.6.1.4.1.4756.20.501.20.1.646 | ColumnnidPort2DiscoveryStateRemoteA | read-only | current | NID Series card Detailed Link OAM Status for Port 2: Discovery State |
| 1.3.6.1.4.1.4756.20.501.20.1.647 | ColumnnidPort2PeerMACAddrRemoteA | read-only | current | NID Series card Detailed Link OAM Status for Port 2: Discovery State |
| 1.3.6.1.4.1.4756.20.501.20.1.648 | ColumnnidPort2RemoteAModeRemoteA | read-only | current | NID Series card Detailed Link OAM Status for Port 2: RemoteA: Mode |
| 1.3.6.1.4.1.4756.20.501.20.1.649 | ColumnnidPort2RemoteAUnOperationRemoteA | read-only | current | NID Series card Detailed Link OAM Status for Port 2: RemoteA: Unidirectional Operation Support |
| 1.3.6.1.4.1.4756.20.501.20.1.650 | ColumnnidPort2RemoteARemoteLbRemoteA | read-only | current | NID Series card Detailed Link OAM Status for Port 2: RemoteA: Remote Loopback Support |
| 1.3.6.1.4.1.4756.20.501.20.1.651 | ColumnnidPort2RemoteALMRemoteA | read-only | current | NID Series card Detailed Link OAM Status for Port 2: RemoteA: Link Monitoring Support |
| 1.3.6.1.4.1.4756.20.501.20.1.652 | ColumnnidPort2RemoteAMIBRetrievalRemoteA | read-only | current | NID Series card Detailed Link OAM Status for Port 2: RemoteA: MIB Retrieval Support |
| 1.3.6.1.4.1.4756.20.501.20.1.653 | ColumnnidPort2RemoteAMTUSizeRemoteA | read-only | current | NID Series card Detailed Link OAM Status for Port 2: RemoteA: MTU Size |
| 1.3.6.1.4.1.4756.20.501.20.1.654 | ColumnnidPort2RemoteAMultiStateRemoteA | read-only | current | NID Series card Detailed Link OAM Status for Port 2: RemoteA: Multiplexer State |
| 1.3.6.1.4.1.4756.20.501.20.1.655 | ColumnnidPort2RemoteAParserStateRemoteA | read-only | current | NID Series card Detailed Link OAM Status for Port 2: RemoteA: Multiplexer State |
| 1.3.6.1.4.1.4756.20.501.20.1.656 | ColumnnidPort2RemoteAOUIRemoteA | read-only | current | NID Series card Detailed Link OAM Status for Port 2: RemoteA: Organizational Unique Identification |
| 1.3.6.1.4.1.4756.20.501.20.1.657 | ColumnnidPort2RemoteAPDURevRemoteA | read-only | current | NID Series card Detailed Link OAM Status for Port 2: RemoteA: PDU Revision |
| 1.3.6.1.4.1.4756.20.501.20.1.658 | ColumnnidPort2PeerModeRemoteA | read-only | current | NID Series card Detailed Link OAM Status for Port 2: Peer: Mode |
| 1.3.6.1.4.1.4756.20.501.20.1.659 | ColumnnidPort2PeerUnOperationRemoteA | read-only | current | NID Series card Detailed Link OAM Status for Port 2: Peer: Unidirectional Operation Support |
| 1.3.6.1.4.1.4756.20.501.20.1.660 | ColumnnidPort2PeerRemoteLbRemoteA | read-only | current | NID Series card Detailed Link OAM Status for Port 2: Peer: Remote Loopback Support |
| 1.3.6.1.4.1.4756.20.501.20.1.661 | ColumnnidPort2PeerLMRemoteA | read-only | current | NID Series card Detailed Link OAM Status for Port 2: Peer: Link Monitoring Support |
| 1.3.6.1.4.1.4756.20.501.20.1.662 | ColumnnidPort2PeerMIBRetrievalRemoteA | read-only | current | NID Series card Detailed Link OAM Status for Port 2: Peer: MIB Retrieval Support |
| 1.3.6.1.4.1.4756.20.501.20.1.663 | ColumnnidPort2PeerMTUSizeRemoteA | read-only | current | NID Series card Detailed Link OAM Status for Port 2: Peer: MTU Size |
| 1.3.6.1.4.1.4756.20.501.20.1.664 | ColumnnidPort2PeerMultiStateRemoteA | read-only | current | NID Series card Detailed Link OAM Status for Port 2: Peer: Multiplexer State |
| 1.3.6.1.4.1.4756.20.501.20.1.665 | ColumnnidPort2PeerParserStateRemoteA | read-only | current | NID Series card Detailed Link OAM Status for Port 2: Peer: Multiplexer State |
| 1.3.6.1.4.1.4756.20.501.20.1.666 | ColumnnidPort2PeerOUIRemoteA | read-only | current | NID Series card Detailed Link OAM Status for Port 2: Peer: Organizational Unique Identification |
| 1.3.6.1.4.1.4756.20.501.20.1.667 | ColumnnidPort2PeerPDURevRemoteA | read-only | current | NID Series card Detailed Link OAM Status for Port 2: Peer: PDU Revision |
| 1.3.6.1.4.1.4756.20.501.20.1.668 | ColumnnidPort3PDUPermisionRemoteA | read-only | current | NID Series card Detailed Link OAM Status for Port 3: PDU Permission |
| 1.3.6.1.4.1.4756.20.501.20.1.669 | ColumnnidPort3DiscoveryStateRemoteA | read-only | current | NID Series card Detailed Link OAM Status for Port 3: Discovery State |
| 1.3.6.1.4.1.4756.20.501.20.1.670 | ColumnnidPort3PeerMACAddrRemoteA | read-only | current | NID Series card Detailed Link OAM Status for Port 3: Discovery State |
| 1.3.6.1.4.1.4756.20.501.20.1.671 | ColumnnidPort3RemoteAModeRemoteA | read-only | current | NID Series card Detailed Link OAM Status for Port 3: RemoteA: Mode |
| 1.3.6.1.4.1.4756.20.501.20.1.672 | ColumnnidPort3RemoteAUnOperationRemoteA | read-only | current | NID Series card Detailed Link OAM Status for Port 3: RemoteA: Unidirectional Operation Support |
| 1.3.6.1.4.1.4756.20.501.20.1.673 | ColumnnidPort3RemoteARemoteLbRemoteA | read-only | current | NID Series card Detailed Link OAM Status for Port 3: RemoteA: Remote Loopback Support |
| 1.3.6.1.4.1.4756.20.501.20.1.674 | ColumnnidPort3RemoteALMRemoteA | read-only | current | NID Series card Detailed Link OAM Status for Port 3: RemoteA: Link Monitoring Support |
| 1.3.6.1.4.1.4756.20.501.20.1.675 | ColumnnidPort3RemoteAMIBRetrievalRemoteA | read-only | current | NID Series card Detailed Link OAM Status for Port 3: RemoteA: MIB Retrieval Support |
| 1.3.6.1.4.1.4756.20.501.20.1.676 | ColumnnidPort3RemoteAMTUSizeRemoteA | read-only | current | NID Series card Detailed Link OAM Status for Port 3: RemoteA: MTU Size |
| 1.3.6.1.4.1.4756.20.501.20.1.677 | ColumnnidPort3RemoteAMultiStateRemoteA | read-only | current | NID Series card Detailed Link OAM Status for Port 3: RemoteA: Multiplexer State |
| 1.3.6.1.4.1.4756.20.501.20.1.678 | ColumnnidPort3RemoteAParserStateRemoteA | read-only | current | NID Series card Detailed Link OAM Status for Port 3: RemoteA: Multiplexer State |
| 1.3.6.1.4.1.4756.20.501.20.1.679 | ColumnnidPort3RemoteAOUIRemoteA | read-only | current | NID Series card Detailed Link OAM Status for Port 3: RemoteA: Organizational Unique Identification |
| 1.3.6.1.4.1.4756.20.501.20.1.680 | ColumnnidPort3RemoteAPDURevRemoteA | read-only | current | NID Series card Detailed Link OAM Status for Port 3: RemoteA: PDU Revision |
| 1.3.6.1.4.1.4756.20.501.20.1.681 | ColumnnidPort3PeerModeRemoteA | read-only | current | NID Series card Detailed Link OAM Status for Port 3: Peer: Mode |
| 1.3.6.1.4.1.4756.20.501.20.1.682 | ColumnnidPort3PeerUnOperationRemoteA | read-only | current | NID Series card Detailed Link OAM Status for Port 3: Peer: Unidirectional Operation Support |
| 1.3.6.1.4.1.4756.20.501.20.1.683 | ColumnnidPort3PeerRemoteLbRemoteA | read-only | current | NID Series card Detailed Link OAM Status for Port 3: Peer: Remote Loopback Support |
| 1.3.6.1.4.1.4756.20.501.20.1.684 | ColumnnidPort3PeerLMRemoteA | read-only | current | NID Series card Detailed Link OAM Status for Port 3: Peer: Link Monitoring Support |
| 1.3.6.1.4.1.4756.20.501.20.1.685 | ColumnnidPort3PeerMIBRetrievalRemoteA | read-only | current | NID Series card Detailed Link OAM Status for Port 3: Peer: MIB Retrieval Support |
| 1.3.6.1.4.1.4756.20.501.20.1.686 | ColumnnidPort3PeerMTUSizeRemoteA | read-only | current | NID Series card Detailed Link OAM Status for Port 3: Peer: MTU Size |
| 1.3.6.1.4.1.4756.20.501.20.1.687 | ColumnnidPort3PeerMultiStateRemoteA | read-only | current | NID Series card Detailed Link OAM Status for Port 3: Peer: Multiplexer State |
| 1.3.6.1.4.1.4756.20.501.20.1.688 | ColumnnidPort3PeerParserStateRemoteA | read-only | current | NID Series card Detailed Link OAM Status for Port 3: Peer: Multiplexer State |
| 1.3.6.1.4.1.4756.20.501.20.1.689 | ColumnnidPort3PeerOUIRemoteA | read-only | current | NID Series card Detailed Link OAM Status for Port 3: Peer: Organizational Unique Identification |
| 1.3.6.1.4.1.4756.20.501.20.1.690 | ColumnnidPort3PeerPDURevRemoteA | read-only | current | NID Series card Detailed Link OAM Status for Port 3: Peer: PDU Revision |
| 1.3.6.1.4.1.4756.20.501.20.1.691 | ColumnnidPort4PDUPermisionRemoteA | read-only | current | NID Series card Detailed Link OAM Status for Port 4: PDU Permission |
| 1.3.6.1.4.1.4756.20.501.20.1.692 | ColumnnidPort4DiscoveryStateRemoteA | read-only | current | NID Series card Detailed Link OAM Status for Port 4: Discovery State |
| 1.3.6.1.4.1.4756.20.501.20.1.693 | ColumnnidPort4PeerMACAddrRemoteA | read-only | current | NID Series card Detailed Link OAM Status for Port 4: Discovery State |
| 1.3.6.1.4.1.4756.20.501.20.1.694 | ColumnnidPort4RemoteAModeRemoteA | read-only | current | NID Series card Detailed Link OAM Status for Port 4: RemoteA: Mode |
| 1.3.6.1.4.1.4756.20.501.20.1.695 | ColumnnidPort4RemoteAUnOperationRemoteA | read-only | current | NID Series card Detailed Link OAM Status for Port 4: RemoteA: Unidirectional Operation Support |
| 1.3.6.1.4.1.4756.20.501.20.1.696 | ColumnnidPort4RemoteARemoteLbRemoteA | read-only | current | NID Series card Detailed Link OAM Status for Port 4: RemoteA: Remote Loopback Support |
| 1.3.6.1.4.1.4756.20.501.20.1.697 | ColumnnidPort4RemoteALMRemoteA | read-only | current | NID Series card Detailed Link OAM Status for Port 4: RemoteA: Link Monitoring Support |
| 1.3.6.1.4.1.4756.20.501.20.1.698 | ColumnnidPort4RemoteAMIBRetrievalRemoteA | read-only | current | NID Series card Detailed Link OAM Status for Port 4: RemoteA: MIB Retrieval Support |
| 1.3.6.1.4.1.4756.20.501.20.1.699 | ColumnnidPort4RemoteAMTUSizeRemoteA | read-only | current | NID Series card Detailed Link OAM Status for Port 4: RemoteA: MTU Size |
| 1.3.6.1.4.1.4756.20.501.20.1.700 | ColumnnidPort4RemoteAMultiStateRemoteA | read-only | current | NID Series card Detailed Link OAM Status for Port 4: RemoteA: Multiplexer State |
| 1.3.6.1.4.1.4756.20.501.20.1.701 | ColumnnidPort4RemoteAParserStateRemoteA | read-only | current | NID Series card Detailed Link OAM Status for Port 4: RemoteA: Multiplexer State |
| 1.3.6.1.4.1.4756.20.501.20.1.702 | ColumnnidPort4RemoteAOUIRemoteA | read-only | current | NID Series card Detailed Link OAM Status for Port 4: RemoteA: Organizational Unique Identification |
| 1.3.6.1.4.1.4756.20.501.20.1.703 | ColumnnidPort4RemoteAPDURevRemoteA | read-only | current | NID Series card Detailed Link OAM Status for Port 4: RemoteA: PDU Revision |
| 1.3.6.1.4.1.4756.20.501.20.1.704 | ColumnnidPort4PeerModeRemoteA | read-only | current | NID Series card Detailed Link OAM Status for Port 4: Peer: Mode |
| 1.3.6.1.4.1.4756.20.501.20.1.705 | ColumnnidPort4PeerUnOperationRemoteA | read-only | current | NID Series card Detailed Link OAM Status for Port 4: Peer: Unidirectional Operation Support |
| 1.3.6.1.4.1.4756.20.501.20.1.706 | ColumnnidPort4PeerRemoteLbRemoteA | read-only | current | NID Series card Detailed Link OAM Status for Port 4: Peer: Remote Loopback Support |
| 1.3.6.1.4.1.4756.20.501.20.1.707 | ColumnnidPort4PeerLMRemoteA | read-only | current | NID Series card Detailed Link OAM Status for Port 4: Peer: Link Monitoring Support |
| 1.3.6.1.4.1.4756.20.501.20.1.708 | ColumnnidPort4PeerMIBRetrievalRemoteA | read-only | current | NID Series card Detailed Link OAM Status for Port 4: Peer: MIB Retrieval Support |
| 1.3.6.1.4.1.4756.20.501.20.1.709 | ColumnnidPort4PeerMTUSizeRemoteA | read-only | current | NID Series card Detailed Link OAM Status for Port 4: Peer: MTU Size |
| 1.3.6.1.4.1.4756.20.501.20.1.710 | ColumnnidPort4PeerMultiStateRemoteA | read-only | current | NID Series card Detailed Link OAM Status for Port 4: Peer: Multiplexer State |
| 1.3.6.1.4.1.4756.20.501.20.1.711 | ColumnnidPort4PeerParserStateRemoteA | read-only | current | NID Series card Detailed Link OAM Status for Port 4: Peer: Multiplexer State |
| 1.3.6.1.4.1.4756.20.501.20.1.712 | ColumnnidPort4PeerOUIRemoteA | read-only | current | NID Series card Detailed Link OAM Status for Port 4: Peer: Organizational Unique Identification |
| 1.3.6.1.4.1.4756.20.501.20.1.713 | ColumnnidPort4PeerPDURevRemoteA | read-only | current | NID Series card Detailed Link OAM Status for Port 4: Peer: PDU Revision |
| 1.3.6.1.4.1.4756.20.501.20.1.714 | ColumnnidPort5PDUPermisionRemoteA | read-only | current | NID Series card Detailed Link OAM Status for Port 5: PDU Permission |
| 1.3.6.1.4.1.4756.20.501.20.1.715 | ColumnnidPort5DiscoveryStateRemoteA | read-only | current | NID Series card Detailed Link OAM Status for Port 5: Discovery State |
| 1.3.6.1.4.1.4756.20.501.20.1.716 | ColumnnidPort5PeerMACAddrRemoteA | read-only | current | NID Series card Detailed Link OAM Status for Port 5: Discovery State |
| 1.3.6.1.4.1.4756.20.501.20.1.717 | ColumnnidPort5RemoteAModeRemoteA | read-only | current | NID Series card Detailed Link OAM Status for Port 5: RemoteA: Mode |
| 1.3.6.1.4.1.4756.20.501.20.1.718 | ColumnnidPort5RemoteAUnOperationRemoteA | read-only | current | NID Series card Detailed Link OAM Status for Port 5: RemoteA: Unidirectional Operation Support |
| 1.3.6.1.4.1.4756.20.501.20.1.719 | ColumnnidPort5RemoteARemoteLbRemoteA | read-only | current | NID Series card Detailed Link OAM Status for Port 5: RemoteA: Remote Loopback Support |
| 1.3.6.1.4.1.4756.20.501.20.1.720 | ColumnnidPort5RemoteALMRemoteA | read-only | current | NID Series card Detailed Link OAM Status for Port 5: RemoteA: Link Monitoring Support |
| 1.3.6.1.4.1.4756.20.501.20.1.721 | ColumnnidPort5RemoteAMIBRetrievalRemoteA | read-only | current | NID Series card Detailed Link OAM Status for Port 5: RemoteA: MIB Retrieval Support |
| 1.3.6.1.4.1.4756.20.501.20.1.722 | ColumnnidPort5RemoteAMTUSizeRemoteA | read-only | current | NID Series card Detailed Link OAM Status for Port 5: RemoteA: MTU Size |
| 1.3.6.1.4.1.4756.20.501.20.1.723 | ColumnnidPort5RemoteAMultiStateRemoteA | read-only | current | NID Series card Detailed Link OAM Status for Port 5: RemoteA: Multiplexer State |
| 1.3.6.1.4.1.4756.20.501.20.1.724 | ColumnnidPort5RemoteAParserStateRemoteA | read-only | current | NID Series card Detailed Link OAM Status for Port 5: RemoteA: Multiplexer State |
| 1.3.6.1.4.1.4756.20.501.20.1.725 | ColumnnidPort5RemoteAOUIRemoteA | read-only | current | NID Series card Detailed Link OAM Status for Port 5: RemoteA: Organizational Unique Identification |
| 1.3.6.1.4.1.4756.20.501.20.1.726 | ColumnnidPort5RemoteAPDURevRemoteA | read-only | current | NID Series card Detailed Link OAM Status for Port 5: RemoteA: PDU Revision |
| 1.3.6.1.4.1.4756.20.501.20.1.727 | ColumnnidPort5PeerModeRemoteA | read-only | current | NID Series card Detailed Link OAM Status for Port 5: Peer: Mode |
| 1.3.6.1.4.1.4756.20.501.20.1.728 | ColumnnidPort5PeerUnOperationRemoteA | read-only | current | NID Series card Detailed Link OAM Status for Port 5: Peer: Unidirectional Operation Support |
| 1.3.6.1.4.1.4756.20.501.20.1.729 | ColumnnidPort5PeerRemoteLbRemoteA | read-only | current | NID Series card Detailed Link OAM Status for Port 5: Peer: Remote Loopback Support |
| 1.3.6.1.4.1.4756.20.501.20.1.730 | ColumnnidPort5PeerLMRemoteA | read-only | current | NID Series card Detailed Link OAM Status for Port 5: Peer: Link Monitoring Support |
| 1.3.6.1.4.1.4756.20.501.20.1.731 | ColumnnidPort5PeerMIBRetrievalRemoteA | read-only | current | NID Series card Detailed Link OAM Status for Port 5: Peer: MIB Retrieval Support |
| 1.3.6.1.4.1.4756.20.501.20.1.732 | ColumnnidPort5PeerMTUSizeRemoteA | read-only | current | NID Series card Detailed Link OAM Status for Port 5: Peer: MTU Size |
| 1.3.6.1.4.1.4756.20.501.20.1.733 | ColumnnidPort5PeerMultiStateRemoteA | read-only | current | NID Series card Detailed Link OAM Status for Port 5: Peer: Multiplexer State |
| 1.3.6.1.4.1.4756.20.501.20.1.734 | ColumnnidPort5PeerParserStateRemoteA | read-only | current | NID Series card Detailed Link OAM Status for Port 5: Peer: Multiplexer State |
| 1.3.6.1.4.1.4756.20.501.20.1.735 | ColumnnidPort5PeerOUIRemoteA | read-only | current | NID Series card Detailed Link OAM Status for Port 5: Peer: Organizational Unique Identification |
| 1.3.6.1.4.1.4756.20.501.20.1.736 | ColumnnidPort5PeerPDURevRemoteA | read-only | current | NID Series card Detailed Link OAM Status for Port 5: Peer: PDU Revision |
| 1.3.6.1.4.1.4756.20.501.20.1.737 | ColumnnidPort6PDUPermisionRemoteA | read-only | current | NID Series card Detailed Link OAM Status for Port 6: PDU Permission |
| 1.3.6.1.4.1.4756.20.501.20.1.738 | ColumnnidPort6DiscoveryStateRemoteA | read-only | current | NID Series card Detailed Link OAM Status for Port 6: Discovery State |
| 1.3.6.1.4.1.4756.20.501.20.1.739 | ColumnnidPort6PeerMACAddrRemoteA | read-only | current | NID Series card Detailed Link OAM Status for Port 6: Discovery State |
| 1.3.6.1.4.1.4756.20.501.20.1.740 | ColumnnidPort6RemoteAModeRemoteA | read-only | current | NID Series card Detailed Link OAM Status for Port 6: RemoteA: Mode |
| 1.3.6.1.4.1.4756.20.501.20.1.741 | ColumnnidPort6RemoteAUnOperationRemoteA | read-only | current | NID Series card Detailed Link OAM Status for Port 6: RemoteA: Unidirectional Operation Support |
| 1.3.6.1.4.1.4756.20.501.20.1.742 | ColumnnidPort6RemoteARemoteLbRemoteA | read-only | current | NID Series card Detailed Link OAM Status for Port 6: RemoteA: Remote Loopback Support |
| 1.3.6.1.4.1.4756.20.501.20.1.743 | ColumnnidPort6RemoteALMRemoteA | read-only | current | NID Series card Detailed Link OAM Status for Port 6: RemoteA: Link Monitoring Support |
| 1.3.6.1.4.1.4756.20.501.20.1.744 | ColumnnidPort6RemoteAMIBRetrievalRemoteA | read-only | current | NID Series card Detailed Link OAM Status for Port 6: RemoteA: MIB Retrieval Support |
| 1.3.6.1.4.1.4756.20.501.20.1.745 | ColumnnidPort6RemoteAMTUSizeRemoteA | read-only | current | NID Series card Detailed Link OAM Status for Port 6: RemoteA: MTU Size |
| 1.3.6.1.4.1.4756.20.501.20.1.746 | ColumnnidPort6RemoteAMultiStateRemoteA | read-only | current | NID Series card Detailed Link OAM Status for Port 6: RemoteA: Multiplexer State |
| 1.3.6.1.4.1.4756.20.501.20.1.747 | ColumnnidPort6RemoteAParserStateRemoteA | read-only | current | NID Series card Detailed Link OAM Status for Port 6: RemoteA: Multiplexer State |
| 1.3.6.1.4.1.4756.20.501.20.1.748 | ColumnnidPort6RemoteAOUIRemoteA | read-only | current | NID Series card Detailed Link OAM Status for Port 6: RemoteA: Organizational Unique Identification |
| 1.3.6.1.4.1.4756.20.501.20.1.749 | ColumnnidPort6RemoteAPDURevRemoteA | read-only | current | NID Series card Detailed Link OAM Status for Port 6: RemoteA: PDU Revision |
| 1.3.6.1.4.1.4756.20.501.20.1.750 | ColumnnidPort6PeerModeRemoteA | read-only | current | NID Series card Detailed Link OAM Status for Port 6: Peer: Mode |
| 1.3.6.1.4.1.4756.20.501.20.1.751 | ColumnnidPort6PeerUnOperationRemoteA | read-only | current | NID Series card Detailed Link OAM Status for Port 6: Peer: Unidirectional Operation Support |
| 1.3.6.1.4.1.4756.20.501.20.1.752 | ColumnnidPort6PeerRemoteLbRemoteA | read-only | current | NID Series card Detailed Link OAM Status for Port 6: Peer: Remote Loopback Support |
| 1.3.6.1.4.1.4756.20.501.20.1.753 | ColumnnidPort6PeerLMRemoteA | read-only | current | NID Series card Detailed Link OAM Status for Port 6: Peer: Link Monitoring Support |
| 1.3.6.1.4.1.4756.20.501.20.1.754 | ColumnnidPort6PeerMIBRetrievalRemoteA | read-only | current | NID Series card Detailed Link OAM Status for Port 6: Peer: MIB Retrieval Support |
| 1.3.6.1.4.1.4756.20.501.20.1.755 | ColumnnidPort6PeerMTUSizeRemoteA | read-only | current | NID Series card Detailed Link OAM Status for Port 6: Peer: MTU Size |
| 1.3.6.1.4.1.4756.20.501.20.1.756 | ColumnnidPort6PeerMultiStateRemoteA | read-only | current | NID Series card Detailed Link OAM Status for Port 6: Peer: Multiplexer State |
| 1.3.6.1.4.1.4756.20.501.20.1.757 | ColumnnidPort6PeerParserStateRemoteA | read-only | current | NID Series card Detailed Link OAM Status for Port 6: Peer: Multiplexer State |
| 1.3.6.1.4.1.4756.20.501.20.1.758 | ColumnnidPort6PeerOUIRemoteA | read-only | current | NID Series card Detailed Link OAM Status for Port 6: Peer: Organizational Unique Identification |
| 1.3.6.1.4.1.4756.20.501.20.1.759 | ColumnnidPort6PeerPDURevRemoteA | read-only | current | NID Series card Detailed Link OAM Status for Port 6: Peer: PDU Revision |
| 1.3.6.1.4.1.4756.20.501.20.1.760 | ColumnnidPort7PDUPermisionRemoteA | read-only | current | NID Series card Detailed Link OAM Status for Port 7: PDU Permission |
| 1.3.6.1.4.1.4756.20.501.20.1.761 | ColumnnidPort7DiscoveryStateRemoteA | read-only | current | NID Series card Detailed Link OAM Status for Port 7: Discovery State |
| 1.3.6.1.4.1.4756.20.501.20.1.762 | ColumnnidPort7PeerMACAddrRemoteA | read-only | current | NID Series card Detailed Link OAM Status for Port 7: Discovery State |
| 1.3.6.1.4.1.4756.20.501.20.1.763 | ColumnnidPort7RemoteAModeRemoteA | read-only | current | NID Series card Detailed Link OAM Status for Port 7: RemoteA: Mode |
| 1.3.6.1.4.1.4756.20.501.20.1.764 | ColumnnidPort7RemoteAUnOperationRemoteA | read-only | current | NID Series card Detailed Link OAM Status for Port 7: RemoteA: Unidirectional Operation Support |
| 1.3.6.1.4.1.4756.20.501.20.1.765 | ColumnnidPort7RemoteARemoteLbRemoteA | read-only | current | NID Series card Detailed Link OAM Status for Port 7: RemoteA: Remote Loopback Support |
| 1.3.6.1.4.1.4756.20.501.20.1.766 | ColumnnidPort7RemoteALMRemoteA | read-only | current | NID Series card Detailed Link OAM Status for Port 7: RemoteA: Link Monitoring Support |
| 1.3.6.1.4.1.4756.20.501.20.1.767 | ColumnnidPort7RemoteAMIBRetrievalRemoteA | read-only | current | NID Series card Detailed Link OAM Status for Port 7: RemoteA: MIB Retrieval Support |
| 1.3.6.1.4.1.4756.20.501.20.1.768 | ColumnnidPort7RemoteAMTUSizeRemoteA | read-only | current | NID Series card Detailed Link OAM Status for Port 7: RemoteA: MTU Size |
| 1.3.6.1.4.1.4756.20.501.20.1.769 | ColumnnidPort7RemoteAMultiStateRemoteA | read-only | current | NID Series card Detailed Link OAM Status for Port 7: RemoteA: Multiplexer State |
| 1.3.6.1.4.1.4756.20.501.20.1.770 | ColumnnidPort7RemoteAParserStateRemoteA | read-only | current | NID Series card Detailed Link OAM Status for Port 7: RemoteA: Multiplexer State |
| 1.3.6.1.4.1.4756.20.501.20.1.771 | ColumnnidPort7RemoteAOUIRemoteA | read-only | current | NID Series card Detailed Link OAM Status for Port 7: RemoteA: Organizational Unique Identification |
| 1.3.6.1.4.1.4756.20.501.20.1.772 | ColumnnidPort7RemoteAPDURevRemoteA | read-only | current | NID Series card Detailed Link OAM Status for Port 7: RemoteA: PDU Revision |
| 1.3.6.1.4.1.4756.20.501.20.1.773 | ColumnnidPort7PeerModeRemoteA | read-only | current | NID Series card Detailed Link OAM Status for Port 7: Peer: Mode |
| 1.3.6.1.4.1.4756.20.501.20.1.774 | ColumnnidPort7PeerUnOperationRemoteA | read-only | current | NID Series card Detailed Link OAM Status for Port 7: Peer: Unidirectional Operation Support |
| 1.3.6.1.4.1.4756.20.501.20.1.775 | ColumnnidPort7PeerRemoteLbRemoteA | read-only | current | NID Series card Detailed Link OAM Status for Port 7: Peer: Remote Loopback Support |
| 1.3.6.1.4.1.4756.20.501.20.1.776 | ColumnnidPort7PeerLMRemoteA | read-only | current | NID Series card Detailed Link OAM Status for Port 7: Peer: Link Monitoring Support |
| 1.3.6.1.4.1.4756.20.501.20.1.777 | ColumnnidPort7PeerMIBRetrievalRemoteA | read-only | current | NID Series card Detailed Link OAM Status for Port 7: Peer: MIB Retrieval Support |
| 1.3.6.1.4.1.4756.20.501.20.1.778 | ColumnnidPort7PeerMTUSizeRemoteA | read-only | current | NID Series card Detailed Link OAM Status for Port 7: Peer: MTU Size |
| 1.3.6.1.4.1.4756.20.501.20.1.779 | ColumnnidPort7PeerMultiStateRemoteA | read-only | current | NID Series card Detailed Link OAM Status for Port 7: Peer: Multiplexer State |
| 1.3.6.1.4.1.4756.20.501.20.1.780 | ColumnnidPort7PeerParserStateRemoteA | read-only | current | NID Series card Detailed Link OAM Status for Port 7: Peer: Multiplexer State |
| 1.3.6.1.4.1.4756.20.501.20.1.781 | ColumnnidPort7PeerOUIRemoteA | read-only | current | NID Series card Detailed Link OAM Status for Port 7: Peer: Organizational Unique Identification |
| 1.3.6.1.4.1.4756.20.501.20.1.782 | ColumnnidPort7PeerPDURevRemoteA | read-only | current | NID Series card Detailed Link OAM Status for Port 7: Peer: PDU Revision |
| 1.3.6.1.4.1.4756.20.501.20.1.783 | ColumnnidPort8PDUPermisionRemoteA | read-only | current | NID Series card Detailed Link OAM Status for Port 8: PDU Permission |
| 1.3.6.1.4.1.4756.20.501.20.1.784 | ColumnnidPort8DiscoveryStateRemoteA | read-only | current | NID Series card Detailed Link OAM Status for Port 8: Discovery State |
| 1.3.6.1.4.1.4756.20.501.20.1.785 | ColumnnidPort8PeerMACAddrRemoteA | read-only | current | NID Series card Detailed Link OAM Status for Port 8: Discovery State |
| 1.3.6.1.4.1.4756.20.501.20.1.786 | ColumnnidPort8RemoteAModeRemoteA | read-only | current | NID Series card Detailed Link OAM Status for Port 8: RemoteA: Mode |
| 1.3.6.1.4.1.4756.20.501.20.1.787 | ColumnnidPort8RemoteAUnOperationRemoteA | read-only | current | NID Series card Detailed Link OAM Status for Port 8: RemoteA: Unidirectional Operation Support |
| 1.3.6.1.4.1.4756.20.501.20.1.788 | ColumnnidPort8RemoteARemoteLbRemoteA | read-only | current | NID Series card Detailed Link OAM Status for Port 8: RemoteA: Remote Loopback Support |
| 1.3.6.1.4.1.4756.20.501.20.1.789 | ColumnnidPort8RemoteALMRemoteA | read-only | current | NID Series card Detailed Link OAM Status for Port 8: RemoteA: Link Monitoring Support |
| 1.3.6.1.4.1.4756.20.501.20.1.790 | ColumnnidPort8RemoteAMIBRetrievalRemoteA | read-only | current | NID Series card Detailed Link OAM Status for Port 8: RemoteA: MIB Retrieval Support |
| 1.3.6.1.4.1.4756.20.501.20.1.791 | ColumnnidPort8RemoteAMTUSizeRemoteA | read-only | current | NID Series card Detailed Link OAM Status for Port 8: RemoteA: MTU Size |
| 1.3.6.1.4.1.4756.20.501.20.1.792 | ColumnnidPort8RemoteAMultiStateRemoteA | read-only | current | NID Series card Detailed Link OAM Status for Port 8: RemoteA: Multiplexer State |
| 1.3.6.1.4.1.4756.20.501.20.1.793 | ColumnnidPort8RemoteAParserStateRemoteA | read-only | current | NID Series card Detailed Link OAM Status for Port 8: RemoteA: Multiplexer State |
| 1.3.6.1.4.1.4756.20.501.20.1.794 | ColumnnidPort8RemoteAOUIRemoteA | read-only | current | NID Series card Detailed Link OAM Status for Port 8: RemoteA: Organizational Unique Identification |
| 1.3.6.1.4.1.4756.20.501.20.1.795 | ColumnnidPort8RemoteAPDURevRemoteA | read-only | current | NID Series card Detailed Link OAM Status for Port 8: RemoteA: PDU Revision |
| 1.3.6.1.4.1.4756.20.501.20.1.796 | ColumnnidPort8PeerModeRemoteA | read-only | current | NID Series card Detailed Link OAM Status for Port 8: Peer: Mode |
| 1.3.6.1.4.1.4756.20.501.20.1.797 | ColumnnidPort8PeerUnOperationRemoteA | read-only | current | NID Series card Detailed Link OAM Status for Port 8: Peer: Unidirectional Operation Support |
| 1.3.6.1.4.1.4756.20.501.20.1.798 | ColumnnidPort8PeerRemoteLbRemoteA | read-only | current | NID Series card Detailed Link OAM Status for Port 8: Peer: Remote Loopback Support |
| 1.3.6.1.4.1.4756.20.501.20.1.799 | ColumnnidPort8PeerLMRemoteA | read-only | current | NID Series card Detailed Link OAM Status for Port 8: Peer: Link Monitoring Support |
| 1.3.6.1.4.1.4756.20.501.20.1.800 | ColumnnidPort8PeerMIBRetrievalRemoteA | read-only | current | NID Series card Detailed Link OAM Status for Port 8: Peer: MIB Retrieval Support |
| 1.3.6.1.4.1.4756.20.501.20.1.801 | ColumnnidPort8PeerMTUSizeRemoteA | read-only | current | NID Series card Detailed Link OAM Status for Port 8: Peer: MTU Size |
| 1.3.6.1.4.1.4756.20.501.20.1.802 | ColumnnidPort8PeerMultiStateRemoteA | read-only | current | NID Series card Detailed Link OAM Status for Port 8: Peer: Multiplexer State |
| 1.3.6.1.4.1.4756.20.501.20.1.803 | ColumnnidPort8PeerParserStateRemoteA | read-only | current | NID Series card Detailed Link OAM Status for Port 8: Peer: Multiplexer State |
| 1.3.6.1.4.1.4756.20.501.20.1.804 | ColumnnidPort8PeerOUIRemoteA | read-only | current | NID Series card Detailed Link OAM Status for Port 8: Peer: Organizational Unique Identification |
| 1.3.6.1.4.1.4756.20.501.20.1.805 | ColumnnidPort8PeerPDURevRemoteA | read-only | current | NID Series card Detailed Link OAM Status for Port 8: Peer: PDU Revision |
| 1.3.6.1.4.1.4756.20.501.20.1.806 | ColumnnidLoopProtectionEnableRemoteA | read-write | current | NID Series card Loop Protection Configuration: General Settings - Enable Loop Protection 0: Disable 1: Enable |
| 1.3.6.1.4.1.4756.20.501.20.1.807 | ColumnnidLoopProtectionTxTimeRemoteA | read-write | current | NID Series card Loop Protection Configuration: General Settings - Transmission Time |
| 1.3.6.1.4.1.4756.20.501.20.1.808 | ColumnnidLoopProtectionShutdownTimeRemoteA | read-write | current | NID Series card Loop Protection Configuration: General Settings - Shutdown Time |
| 1.3.6.1.4.1.4756.20.501.20.1.809 | ColumnnidLoopProtectionPort1EnabledRemoteA | read-write | current | NID Series card Loop Protection Configuration for Port 1: Port Configuration - Enable 0: Disable 1: Enable |
| 1.3.6.1.4.1.4756.20.501.20.1.810 | ColumnnidLoopProtectionPort1ActionRemoteA | read-write | current | NID Series card Loop Protection Configuration for Port 1: Port Configuration - Action 0: Shutdown Port 1: Shutdown Port And Log 2: Log Only |
| 1.3.6.1.4.1.4756.20.501.20.1.811 | ColumnnidLoopProtectionPort1TxModeRemoteA | read-write | current | NID Series card Loop Protection Configuration for Port 1: Port Configuration - Tx Mode 0: Disable 1: Enable |
| 1.3.6.1.4.1.4756.20.501.20.1.812 | ColumnnidLoopProtectionPort2EnabledRemoteA | read-write | current | NID Series card Loop Protection Configuration for Port 2: Port Configuration - Enable 0: Disable 1: Enable |
| 1.3.6.1.4.1.4756.20.501.20.1.813 | ColumnnidLoopProtectionPort2ActionRemoteA | read-write | current | NID Series card Loop Protection Configuration for Port 2: Port Configuration - Action 0: Shutdown Port 1: Shutdown Port And Log 2: Log Only |
| 1.3.6.1.4.1.4756.20.501.20.1.814 | ColumnnidLoopProtectionPort2TxModeRemoteA | read-write | current | NID Series card Loop Protection Configuration for Port 2: Port Configuration - Tx Mode 0: Disable 1: Enable |
| 1.3.6.1.4.1.4756.20.501.20.1.815 | ColumnnidLoopProtectionPort3EnabledRemoteA | read-write | current | NID Series card Loop Protection Configuration for Port 3: Port Configuration - Enable 0: Disable 1: Enable |
| 1.3.6.1.4.1.4756.20.501.20.1.816 | ColumnnidLoopProtectionPort3ActionRemoteA | read-write | current | NID Series card Loop Protection Configuration for Port 3: Port Configuration - Action 0: Shutdown Port 1: Shutdown Port And Log 2: Log Only |
| 1.3.6.1.4.1.4756.20.501.20.1.817 | ColumnnidLoopProtectionPort3TxModeRemoteA | read-write | current | NID Series card Loop Protection Configuration for Port 3: Port Configuration - Tx Mode 0: Disable 1: Enable |
| 1.3.6.1.4.1.4756.20.501.20.1.818 | ColumnnidLoopProtectionPort4EnabledRemoteA | read-write | current | NID Series card Loop Protection Configuration for Port 4: Port Configuration - Enable 0: Disable 1: Enable |
| 1.3.6.1.4.1.4756.20.501.20.1.819 | ColumnnidLoopProtectionPort4ActionRemoteA | read-write | current | NID Series card Loop Protection Configuration for Port 4: Port Configuration - Action 0: Shutdown Port 1: Shutdown Port And Log 2: Log Only |
| 1.3.6.1.4.1.4756.20.501.20.1.820 | ColumnnidLoopProtectionPort4TxModeRemoteA | read-write | current | NID Series card Loop Protection Configuration for Port 41: Port Configuration - Tx Mode 0: Disable 1: Enable |
| 1.3.6.1.4.1.4756.20.501.20.1.821 | ColumnnidLoopProtectionPort5EnabledRemoteA | read-write | current | NID Series card Loop Protection Configuration for Port 5: Port Configuration - Enable 0: Disable 1: Enable |
| 1.3.6.1.4.1.4756.20.501.20.1.822 | ColumnnidLoopProtectionPort5ActionRemoteA | read-write | current | NID Series card Loop Protection Configuration for Port 5: Port Configuration - Action 0: Shutdown Port 1: Shutdown Port And Log 2: Log Only |
| 1.3.6.1.4.1.4756.20.501.20.1.823 | ColumnnidLoopProtectionPort5TxModeRemoteA | read-write | current | NID Series card Loop Protection Configuration for Port 5: Port Configuration - Tx Mode 0: Disable 1: Enable |
| 1.3.6.1.4.1.4756.20.501.20.1.824 | ColumnnidLoopProtectionPort6EnabledRemoteA | read-write | current | NID Series card Loop Protection Configuration for Port 6: Port Configuration - Enable 0: Disable 1: Enable |
| 1.3.6.1.4.1.4756.20.501.20.1.825 | ColumnnidLoopProtectionPort6ActionRemoteA | read-write | current | NID Series card Loop Protection Configuration for Port 6: Port Configuration - Action 0: Shutdown Port 1: Shutdown Port And Log 2: Log Only |
| 1.3.6.1.4.1.4756.20.501.20.1.826 | ColumnnidLoopProtectionPort6TxModeRemoteA | read-write | current | NID Series card Loop Protection Configuration for Port 6: Port Configuration - Tx Mode 0: Disable 1: Enable |
| 1.3.6.1.4.1.4756.20.501.20.1.827 | ColumnnidLoopProtectionPort7EnabledRemoteA | read-write | current | NID Series card Loop Protection Configuration for Port 7: Port Configuration - Enable 0: Disable 1: Enable |
| 1.3.6.1.4.1.4756.20.501.20.1.828 | ColumnnidLoopProtectionPort7ActionRemoteA | read-write | current | NID Series card Loop Protection Configuration for Port 7: Port Configuration - Action 0: Shutdown Port 1: Shutdown Port And Log 2: Log Only |
| 1.3.6.1.4.1.4756.20.501.20.1.829 | ColumnnidLoopProtectionPort7TxModeRemoteA | read-write | current | NID Series card Loop Protection Configuration for Port 7: Port Configuration - Tx Mode 0: Disable 1: Enable |
| 1.3.6.1.4.1.4756.20.501.20.1.830 | ColumnnidLoopProtectionPort8EnabledRemoteA | read-write | current | NID Series card Loop Protection Configuration for Port 8: Port Configuration - Enable 0: Disable 1: Enable |
| 1.3.6.1.4.1.4756.20.501.20.1.831 | ColumnnidLoopProtectionPort8ActionRemoteA | read-write | current | NID Series card Loop Protection Configuration for Port 8: Port Configuration - Action 0: Shutdown Port 1: Shutdown Port And Log 2: Log Only |
| 1.3.6.1.4.1.4756.20.501.20.1.832 | ColumnnidLoopProtectionPort8TxModeRemoteA | read-write | current | NID Series card Loop Protection Configuration for Port 8: Port Configuration - Tx Mode 0: Disable 1: Enable |
| 1.3.6.1.4.1.4756.20.501.20.1.833 | ColumnnidLoopProtectionPort1ActionStsRemoteA | read-only | current | NID Series card Loop Protection Status for Port 1: Action |
| 1.3.6.1.4.1.4756.20.501.20.1.834 | ColumnnidLoopProtectionPort1TransStsRemoteA | read-only | current | NID Series card Loop Protection Status for Port 1: Transmit |
| 1.3.6.1.4.1.4756.20.501.20.1.835 | ColumnnidLoopProtectionPort1LoopsStsRemoteA | read-only | current | NID Series card Loop Protection Status for Port 1: Loops |
| 1.3.6.1.4.1.4756.20.501.20.1.836 | ColumnnidLoopProtectionPort1StatusRemoteA | read-only | current | NID Series card Loop Protection Status for Port 1: Status |
| 1.3.6.1.4.1.4756.20.501.20.1.837 | ColumnnidLoopProtectionPort1LoopStsRemoteA | read-only | current | NID Series card Loop Protection Status for Port 1: Loop |
| 1.3.6.1.4.1.4756.20.501.20.1.838 | ColumnnidLoopProtectionPort1TimeOfLastLoopRemoteA | read-only | current | NID Series card Loop Protection Status for Port 1: Time of Last Loop |
| 1.3.6.1.4.1.4756.20.501.20.1.839 | ColumnnidLoopProtectionPort2ActionStsRemoteA | read-only | current | NID Series card Loop Protection Status for Port 2: Action |
| 1.3.6.1.4.1.4756.20.501.20.1.840 | ColumnnidLoopProtectionPort2TransStsRemoteA | read-only | current | NID Series card Loop Protection Status for Port 2: Transmit |
| 1.3.6.1.4.1.4756.20.501.20.1.841 | ColumnnidLoopProtectionPort2LoopsStsRemoteA | read-only | current | NID Series card Loop Protection Status for Port 2: Loops |
| 1.3.6.1.4.1.4756.20.501.20.1.842 | ColumnnidLoopProtectionPort2StatusRemoteA | read-only | current | NID Series card Loop Protection Status for Port 2: Status |
| 1.3.6.1.4.1.4756.20.501.20.1.843 | ColumnnidLoopProtectionPort2LoopStsRemoteA | read-only | current | NID Series card Loop Protection Status for Port 2: Loop |
| 1.3.6.1.4.1.4756.20.501.20.1.844 | ColumnnidLoopProtectionPort2TimeOfLastLoopRemoteA | read-only | current | NID Series card Loop Protection Status for Port 2: Time of Last Loop |
| 1.3.6.1.4.1.4756.20.501.20.1.845 | ColumnnidLoopProtectionPort3ActionStsRemoteA | read-only | current | NID Series card Loop Protection Status for Port 3: Action |
| 1.3.6.1.4.1.4756.20.501.20.1.846 | ColumnnidLoopProtectionPort3TransStsRemoteA | read-only | current | NID Series card Loop Protection Status for Port 3: Transmit |
| 1.3.6.1.4.1.4756.20.501.20.1.847 | ColumnnidLoopProtectionPort3LoopsStsRemoteA | read-only | current | NID Series card Loop Protection Status for Port 3: Loops |
| 1.3.6.1.4.1.4756.20.501.20.1.848 | ColumnnidLoopProtectionPort3StatusRemoteA | read-only | current | NID Series card Loop Protection Status for Port 3: Status |
| 1.3.6.1.4.1.4756.20.501.20.1.849 | ColumnnidLoopProtectionPort3LoopStsRemoteA | read-only | current | NID Series card Loop Protection Status for Port 3: Loop |
| 1.3.6.1.4.1.4756.20.501.20.1.850 | ColumnnidLoopProtectionPort3TimeOfLastLoopRemoteA | read-only | current | NID Series card Loop Protection Status for Port 3: Time of Last Loop |
| 1.3.6.1.4.1.4756.20.501.20.1.851 | ColumnnidLoopProtectionPort4ActionStsRemoteA | read-only | current | NID Series card Loop Protection Status for Port 4: Action |
| 1.3.6.1.4.1.4756.20.501.20.1.852 | ColumnnidLoopProtectionPort4TransStsRemoteA | read-only | current | NID Series card Loop Protection Status for Port 4: Transmit |
| 1.3.6.1.4.1.4756.20.501.20.1.853 | ColumnnidLoopProtectionPort4LoopsStsRemoteA | read-only | current | NID Series card Loop Protection Status for Port 4: Loops |
| 1.3.6.1.4.1.4756.20.501.20.1.854 | ColumnnidLoopProtectionPort4StatusRemoteA | read-only | current | NID Series card Loop Protection Status for Port 4: Status |
| 1.3.6.1.4.1.4756.20.501.20.1.855 | ColumnnidLoopProtectionPort4LoopStsRemoteA | read-only | current | NID Series card Loop Protection Status for Port 4: Loop |
| 1.3.6.1.4.1.4756.20.501.20.1.856 | ColumnnidLoopProtectionPort4TimeOfLastLoopRemoteA | read-only | current | NID Series card Loop Protection Status for Port 4: Time of Last Loop |
| 1.3.6.1.4.1.4756.20.501.20.1.857 | ColumnnidLoopProtectionPort5ActionStsRemoteA | read-only | current | NID Series card Loop Protection Status for Port 5: Action |
| 1.3.6.1.4.1.4756.20.501.20.1.858 | ColumnnidLoopProtectionPort5TransStsRemoteA | read-only | current | NID Series card Loop Protection Status for Port 5: Transmit |
| 1.3.6.1.4.1.4756.20.501.20.1.859 | ColumnnidLoopProtectionPort5LoopsStsRemoteA | read-only | current | NID Series card Loop Protection Status for Port 5: Loops |
| 1.3.6.1.4.1.4756.20.501.20.1.860 | ColumnnidLoopProtectionPort5StatusRemoteA | read-only | current | NID Series card Loop Protection Status for Port 5: Status |
| 1.3.6.1.4.1.4756.20.501.20.1.861 | ColumnnidLoopProtectionPort5LoopStsRemoteA | read-only | current | NID Series card Loop Protection Status for Port 5: Loop |
| 1.3.6.1.4.1.4756.20.501.20.1.862 | ColumnnidLoopProtectionPort5TimeOfLastLoopRemoteA | read-only | current | NID Series card Loop Protection Status for Port 5: Time of Last Loop |
| 1.3.6.1.4.1.4756.20.501.20.1.863 | ColumnnidLoopProtectionPort6ActionStsRemoteA | read-only | current | NID Series card Loop Protection Status for Port 6: Action |
| 1.3.6.1.4.1.4756.20.501.20.1.864 | ColumnnidLoopProtectionPort6TransStsRemoteA | read-only | current | NID Series card Loop Protection Status for Port 6: Transmit |
| 1.3.6.1.4.1.4756.20.501.20.1.865 | ColumnnidLoopProtectionPort6LoopsStsRemoteA | read-only | current | NID Series card Loop Protection Status for Port 6: Loops |
| 1.3.6.1.4.1.4756.20.501.20.1.866 | ColumnnidLoopProtectionPort6StatusRemoteA | read-only | current | NID Series card Loop Protection Status for Port 64: Status |
| 1.3.6.1.4.1.4756.20.501.20.1.867 | ColumnnidLoopProtectionPort6LoopStsRemoteA | read-only | current | NID Series card Loop Protection Status for Port 64: Loop |
| 1.3.6.1.4.1.4756.20.501.20.1.868 | ColumnnidLoopProtectionPort6TimeOfLastLoopRemoteA | read-only | current | NID Series card Loop Protection Status for Port 6: Time of Last Loop |
| 1.3.6.1.4.1.4756.20.501.20.1.869 | ColumnnidLoopProtectionPort7ActionStsRemoteA | read-only | current | NID Series card Loop Protection Status for Port 7: Action |
| 1.3.6.1.4.1.4756.20.501.20.1.870 | ColumnnidLoopProtectionPort7TransStsRemoteA | read-only | current | NID Series card Loop Protection Status for Port 7: Transmit |
| 1.3.6.1.4.1.4756.20.501.20.1.871 | ColumnnidLoopProtectionPort7LoopsStsRemoteA | read-only | current | NID Series card Loop Protection Status for Port 7: Loops |
| 1.3.6.1.4.1.4756.20.501.20.1.872 | ColumnnidLoopProtectionPort7StatusRemoteA | read-only | current | NID Series card Loop Protection Status for Port 7: Status |
| 1.3.6.1.4.1.4756.20.501.20.1.873 | ColumnnidLoopProtectionPort7LoopStsRemoteA | read-only | current | NID Series card Loop Protection Status for Port 7: Loop |
| 1.3.6.1.4.1.4756.20.501.20.1.874 | ColumnnidLoopProtectionPort7TimeOfLastLoopRemoteA | read-only | current | NID Series card Loop Protection Status for Port 7: Time of Last Loop |
| 1.3.6.1.4.1.4756.20.501.20.1.875 | ColumnnidLoopProtectionPort8ActionStsRemoteA | read-only | current | NID Series card Loop Protection Status for Port 8: Action |
| 1.3.6.1.4.1.4756.20.501.20.1.876 | ColumnnidLoopProtectionPort8TransStsRemoteA | read-only | current | NID Series card Loop Protection Status for Port 8: Transmit |
| 1.3.6.1.4.1.4756.20.501.20.1.877 | ColumnnidLoopProtectionPort8LoopsStsRemoteA | read-only | current | NID Series card Loop Protection Status for Port 8: Loops |
| 1.3.6.1.4.1.4756.20.501.20.1.878 | ColumnnidLoopProtectionPort8StatusRemoteA | read-only | current | NID Series card Loop Protection Status for Port 8: Status |
| 1.3.6.1.4.1.4756.20.501.20.1.879 | ColumnnidLoopProtectionPort8LoopStsRemoteA | read-only | current | NID Series card Loop Protection Status for Port 8: Loop |
| 1.3.6.1.4.1.4756.20.501.20.1.880 | ColumnnidLoopProtectionPort8TimeOfLastLoopRemoteA | read-only | current | NID Series card Loop Protection Status for Port 8: Time of Last Loop |
| 1.3.6.1.4.1.4756.20.501.20.1.881 | ColumnniduRingInstanceAddRemoteA | read-write | current | NID Series card Add a new uRing Instance. Syntax: <Instance ID> <ring|sub|chain> <port east> <port west> Instance ID must be either 1 or 2 port east , the valu… |
| 1.3.6.1.4.1.4756.20.501.20.1.882 | ColumnniduRingInstanceDeleteRemoteA | read-write | current | NID Series card Delete a uRing Instance. Syntax: <uRing Instance> |
| 1.3.6.1.4.1.4756.20.501.20.1.883 | ColumnniduRingInst1IDRemoteA | read-only | current | NID Series card u-Ring instance1 ID |
| 1.3.6.1.4.1.4756.20.501.20.1.884 | ColumnniduRingInst1typeRemoteA | read-only | current | NID Series card u-Ring instance1 type 0: u-Ring 1: Sub-Ring 2: u-Chain |
| 1.3.6.1.4.1.4756.20.501.20.1.885 | ColumnniduRingInst1masterRemoteA | read-write | current | NID Series card u-Ring instance1 master 0: No 1: Yes |
| 1.3.6.1.4.1.4756.20.501.20.1.886 | ColumnniduRingInst1EastPortRemoteA | read-only | current | NID Series card u-Ring instance1 east port |
| 1.3.6.1.4.1.4756.20.501.20.1.887 | ColumnniduRingInst1EastEdgeRemoteA | read-write | current | NID Series card u-Ring instance1 east edge 0: No 1: Yes |
| 1.3.6.1.4.1.4756.20.501.20.1.888 | ColumnniduRingInst1WestPortRemoteA | read-only | current | NID Series card u-Ring instance1 west port |
| 1.3.6.1.4.1.4756.20.501.20.1.889 | ColumnniduRingInst1WestEdgeRemoteA | read-write | current | NID Series card u-Ring instance1 west edge 0: No 1: Yes |
| 1.3.6.1.4.1.4756.20.501.20.1.890 | ColumnniduRingInst2IDRemoteA | read-only | current | NID Series card u-Ring instance2 ID |
| 1.3.6.1.4.1.4756.20.501.20.1.891 | ColumnniduRingInst2typeRemoteA | read-only | current | NID Series card u-Ring instance2 type 0: u-Ring 1: Sub-Ring 2: u-Chain |
| 1.3.6.1.4.1.4756.20.501.20.1.892 | ColumnniduRingInst2masterRemoteA | read-write | current | NID Series card u-Ring instance2 master 0: No 1: Yes |
| 1.3.6.1.4.1.4756.20.501.20.1.893 | ColumnniduRingInst2EastPortRemoteA | read-only | current | NID Series card u-Ring instance2 east port |
| 1.3.6.1.4.1.4756.20.501.20.1.894 | ColumnniduRingInst2EastEdgeRemoteA | read-write | current | NID Series card u-Ring instance2 east edge 0: No 1: Yes |
| 1.3.6.1.4.1.4756.20.501.20.1.895 | ColumnniduRingInst2WestPortRemoteA | read-only | current | NID Series card u-Ring instance2 west port |
| 1.3.6.1.4.1.4756.20.501.20.1.896 | ColumnniduRingInst2WestEdgeRemoteA | read-write | current | NID Series card u-Ring instance2 west edge 0: No 1: Yes |
| 1.3.6.1.4.1.4756.20.501.20.1.897 | ColumnniduRingInst3IDRemoteA | read-only | current | NID Series card u-Ring instance3 ID |
| 1.3.6.1.4.1.4756.20.501.20.1.898 | ColumnniduRingInst3typeRemoteA | read-only | current | NID Series card u-Ring instance3 type 0: u-Ring 1: Sub-Ring 2: u-Chain |
| 1.3.6.1.4.1.4756.20.501.20.1.899 | ColumnniduRingInst3masterRemoteA | read-write | current | NID Series card u-Ring instance3 master 0: No 1: Yes |
| 1.3.6.1.4.1.4756.20.501.20.1.900 | ColumnniduRingInst3EastPortRemoteA | read-only | current | NID Series card u-Ring instance3 east port |
| 1.3.6.1.4.1.4756.20.501.20.1.901 | ColumnniduRingInst3EastEdgeRemoteA | read-write | current | NID Series card u-Ring instance3 east edge 0: No 1: Yes |
| 1.3.6.1.4.1.4756.20.501.20.1.902 | ColumnniduRingInst3WestPortRemoteA | read-only | current | NID Series card u-Ring instance3 west port |
| 1.3.6.1.4.1.4756.20.501.20.1.903 | ColumnniduRingInst3WestEdgeRemoteA | read-write | current | NID Series card u-Ring instance3 west edge 0: No 1: Yes |
| 1.3.6.1.4.1.4756.20.501.20.1.904 | ColumnniduRingInst4IDRemoteA | read-only | current | NID Series card u-Ring instance4 ID |
| 1.3.6.1.4.1.4756.20.501.20.1.905 | ColumnniduRingInst4typeRemoteA | read-only | current | NID Series card u-Ring instance4 type 0: u-Ring 1: Sub-Ring 2: u-Chain |
| 1.3.6.1.4.1.4756.20.501.20.1.906 | ColumnniduRingInst4masterRemoteA | read-write | current | NID Series card u-Ring instance4 master 0: No 1: Yes |
| 1.3.6.1.4.1.4756.20.501.20.1.907 | ColumnniduRingInst4EastPortRemoteA | read-only | current | NID Series card u-Ring instance4 east port |
| 1.3.6.1.4.1.4756.20.501.20.1.908 | ColumnniduRingInst4EastEdgeRemoteA | read-write | current | NID Series card u-Ring instance4 east edge 0: No 1: Yes |
| 1.3.6.1.4.1.4756.20.501.20.1.909 | ColumnniduRingInst4WestPortRemoteA | read-only | current | NID Series card u-Ring instance4 west port |
| 1.3.6.1.4.1.4756.20.501.20.1.910 | ColumnniduRingInst4WestEdgeRemoteA | read-write | current | NID Series card u-Ring instance4 west edge 0: No 1: Yes |
| 1.3.6.1.4.1.4756.20.501.20.1.911 | ColumnniduRingInst1IDstsRemoteA | read-only | current | NID Series card u-Ring Instance1 ID status |
| 1.3.6.1.4.1.4756.20.501.20.1.912 | ColumnniduRingInst1typestsRemoteA | read-only | current | NID Series card u-Ring Type status |
| 1.3.6.1.4.1.4756.20.501.20.1.913 | ColumnniduRingInst1rolestsRemoteA | read-only | current | NID Series card u-Ring Role status |
| 1.3.6.1.4.1.4756.20.501.20.1.914 | ColumnniduRingInst1EastPortstsRemoteA | read-only | current | NID Series card u-Ring East port status |
| 1.3.6.1.4.1.4756.20.501.20.1.915 | ColumnniduRingInst1EaststsRemoteA | read-only | current | NID Series card u-Ring East status |
| 1.3.6.1.4.1.4756.20.501.20.1.916 | ColumnniduRingInst1EastEdgestsRemoteA | read-only | current | NID Series card u-Ring East edge status |
| 1.3.6.1.4.1.4756.20.501.20.1.917 | ColumnniduRingInst1WestPortstsRemoteA | read-only | current | NID Series card u-Ring West edge status |
| 1.3.6.1.4.1.4756.20.501.20.1.918 | ColumnniduRingInst1WeststsRemoteA | read-only | current | NID Series card u-Ring West status |
| 1.3.6.1.4.1.4756.20.501.20.1.919 | ColumnniduRingInst1WestEdgestsRemoteA | read-only | current | NID Series card u-Ring West status |
| 1.3.6.1.4.1.4756.20.501.20.1.920 | ColumnniduRingInst1healthystsRemoteA | read-only | current | NID Series card u-Ring healthy status None Fine Fault |
| 1.3.6.1.4.1.4756.20.501.20.1.921 | ColumnniduRingInst2IDstsRemoteA | read-only | current | NID Series card u-Ring Instance2 ID status |
| 1.3.6.1.4.1.4756.20.501.20.1.922 | ColumnniduRingInst2typestsRemoteA | read-only | current | NID Series card u-Ring Type status |
| 1.3.6.1.4.1.4756.20.501.20.1.923 | ColumnniduRingInst2rolestsRemoteA | read-only | current | NID Series card u-Ring Role status |
| 1.3.6.1.4.1.4756.20.501.20.1.924 | ColumnniduRingInst2EastPortstsRemoteA | read-only | current | NID Series card u-Ring East port status |
| 1.3.6.1.4.1.4756.20.501.20.1.925 | ColumnniduRingInst2EaststsRemoteA | read-only | current | NID Series card u-Ring East status |
| 1.3.6.1.4.1.4756.20.501.20.1.926 | ColumnniduRingInst2EastEdgestsRemoteA | read-only | current | NID Series card u-Ring East edge status |
| 1.3.6.1.4.1.4756.20.501.20.1.927 | ColumnniduRingInst2WestPortstsRemoteA | read-only | current | NID Series card u-Ring West edge status |
| 1.3.6.1.4.1.4756.20.501.20.1.928 | ColumnniduRingInst2WeststsRemoteA | read-only | current | NID Series card u-Ring West status |
| 1.3.6.1.4.1.4756.20.501.20.1.929 | ColumnniduRingInst2WestEdgestsRemoteA | read-only | current | NID Series card u-Ring West status |
| 1.3.6.1.4.1.4756.20.501.20.1.930 | ColumnniduRingInst2healthystsRemoteA | read-only | current | NID Series card u-Ring healthy status None Fine Fault |
| 1.3.6.1.4.1.4756.20.501.20.1.931 | ColumnniduRingInst3IDstsRemoteA | read-only | current | NID Series card u-Ring Instance3 ID status |
| 1.3.6.1.4.1.4756.20.501.20.1.932 | ColumnniduRingInst3typestsRemoteA | read-only | current | NID Series card u-Ring Type status |
| 1.3.6.1.4.1.4756.20.501.20.1.933 | ColumnniduRingInst3rolestsRemoteA | read-only | current | NID Series card u-Ring Role status |
| 1.3.6.1.4.1.4756.20.501.20.1.934 | ColumnniduRingInst3EastPortstsRemoteA | read-only | current | NID Series card u-Ring East port status |
| 1.3.6.1.4.1.4756.20.501.20.1.935 | ColumnniduRingInst3EaststsRemoteA | read-only | current | NID Series card u-Ring East status |
| 1.3.6.1.4.1.4756.20.501.20.1.936 | ColumnniduRingInst3EastEdgestsRemoteA | read-only | current | NID Series card u-Ring East edge status |
| 1.3.6.1.4.1.4756.20.501.20.1.937 | ColumnniduRingInst3WestPortstsRemoteA | read-only | current | NID Series card u-Ring West edge status |
| 1.3.6.1.4.1.4756.20.501.20.1.938 | ColumnniduRingInst3WeststsRemoteA | read-only | current | NID Series card u-Ring West status |
| 1.3.6.1.4.1.4756.20.501.20.1.939 | ColumnniduRingInst3WestEdgestsRemoteA | read-only | current | NID Series card u-Ring West status |
| 1.3.6.1.4.1.4756.20.501.20.1.940 | ColumnniduRingInst3healthystsRemoteA | read-only | current | NID Series card u-Ring healthy status None Fine Fault |
| 1.3.6.1.4.1.4756.20.501.20.1.941 | ColumnniduRingInst4IDstsRemoteA | read-only | current | NID Series card u-Ring Instance4 ID status |
| 1.3.6.1.4.1.4756.20.501.20.1.942 | ColumnniduRingInst4typestsRemoteA | read-only | current | NID Series card u-Ring Type status |
| 1.3.6.1.4.1.4756.20.501.20.1.943 | ColumnniduRingInst4rolestsRemoteA | read-only | current | NID Series card u-Ring Role status |
| 1.3.6.1.4.1.4756.20.501.20.1.944 | ColumnniduRingInst4EastPortstsRemoteA | read-only | current | NID Series card u-Ring East port status |
| 1.3.6.1.4.1.4756.20.501.20.1.945 | ColumnniduRingInst4EaststsRemoteA | read-only | current | NID Series card u-Ring East status |
| 1.3.6.1.4.1.4756.20.501.20.1.946 | ColumnniduRingInst4EastEdgestsRemoteA | read-only | current | NID Series card u-Ring East edge status |
| 1.3.6.1.4.1.4756.20.501.20.1.947 | ColumnniduRingInst4WestPortstsRemoteA | read-only | current | NID Series card u-Ring West edge status |
| 1.3.6.1.4.1.4756.20.501.20.1.948 | ColumnniduRingInst4WeststsRemoteA | read-only | current | NID Series card u-Ring West status |
| 1.3.6.1.4.1.4756.20.501.20.1.949 | ColumnniduRingInst4WestEdgestsRemoteA | read-only | current | NID Series card u-Ring West status |
| 1.3.6.1.4.1.4756.20.501.20.1.950 | ColumnniduRingInst4healthystsRemoteA | read-only | current | NID Series card u-Ring healthy status None Fine Fault |
| 1.3.6.1.4.1.4756.20.501.20.1.951 | ColumnnidSTPProtocolVersionRemoteA | read-write | current | NID Series card STP Bridge Configuration: Basic Settings - Protocol Version 0: STP 1: RSTP 2: MSTP |
| 1.3.6.1.4.1.4756.20.501.20.1.952 | ColumnnidSTPBridgePriorityRemoteA | read-write | current | NID Series card STP Bridge Configuration: Basic Settings - Bridge Priority 0: 0 1: 4096 2: 8192 3: 12288 4: 16384 5: 20480 6: 24576 7: 28672 8: 32768 9: 36864 … |
| 1.3.6.1.4.1.4756.20.501.20.1.953 | ColumnnidSTPForwardDelayRemoteA | read-write | current | NID Series card STP Bridge Configuration: Basic Settings - Forward Delay |
| 1.3.6.1.4.1.4756.20.501.20.1.954 | ColumnnidSTPMaxAgeRemoteA | read-write | current | NID Series card STP Bridge Configuration: Basic Settings - Max Age |
| 1.3.6.1.4.1.4756.20.501.20.1.955 | ColumnnidSTPMaximumHopCountRemoteA | read-write | current | NID Series card STP Bridge Configuration: Basic Settings - Maximum Hop Count |
| 1.3.6.1.4.1.4756.20.501.20.1.956 | ColumnnidSTPTransmitHoldCountRemoteA | read-write | current | NID Series card STP Bridge Configuration: Basic Settings - Transmit Hold Count |
| 1.3.6.1.4.1.4756.20.501.20.1.957 | ColumnnidSTPEdgePortBPDUFilteringRemoteA | read-write | current | NID Series card STP Bridge Configuration: Advanced Settings - Edge Port BPDU Filtering 0: Off 1: On |
| 1.3.6.1.4.1.4756.20.501.20.1.958 | ColumnnidSTPEdgePortBPDUGuardRemoteA | read-write | current | NID Series card STP Bridge Configuration: Advanced Settings - Edge Port BPDU Guard 0: Off 1: On |
| 1.3.6.1.4.1.4756.20.501.20.1.959 | ColumnnidSTPPortErrorRecoveryTimeoutRemoteA | read-write | current | NID Series card STP Bridge Configuration: Advanced Settings - Port Error Recovery Timeout 0: Off 1: On |
| 1.3.6.1.4.1.4756.20.501.20.1.960 | ColumnnidMSTIConfigurationNameRemoteA | read-write | current | NID Series card MSTI Configuration: Configuration Identification - Configuration Name |
| 1.3.6.1.4.1.4756.20.501.20.1.961 | ColumnnidMSTIConfigurationRevisionRemoteA | read-write | current | NID Series card MSTI Configuration: Configuration Identification - Configuration Revision |
| 1.3.6.1.4.1.4756.20.501.20.1.962 | ColumnnidMSTI1VLANsMappingRemoteA | read-write | current | NID Series card MSTI Configuration: MSTI Mapping - MSTI 1 |
| 1.3.6.1.4.1.4756.20.501.20.1.963 | ColumnnidMSTI2VLANsMappingRemoteA | read-write | current | NID Series card MSTI Configuration: MSTI Mapping - MSTI 2 |
| 1.3.6.1.4.1.4756.20.501.20.1.964 | ColumnnidMSTI3VLANsMappingRemoteA | read-write | current | NID Series card MSTI Configuration: MSTI Mapping - MSTI 3 |
| 1.3.6.1.4.1.4756.20.501.20.1.965 | ColumnnidMSTI4VLANsMappingRemoteA | read-write | current | NID Series card MSTI Configuration: MSTI Mapping - MSTI 4 |
| 1.3.6.1.4.1.4756.20.501.20.1.966 | ColumnnidMSTI5VLANsMappingRemoteA | read-write | current | NID Series card MSTI Configuration: MSTI Mapping - MSTI 5 |
| 1.3.6.1.4.1.4756.20.501.20.1.967 | ColumnnidMSTI6VLANsMappingRemoteA | read-write | current | NID Series card MSTI Configuration: MSTI Mapping - MSTI 6 |
| 1.3.6.1.4.1.4756.20.501.20.1.968 | ColumnnidMSTI7VLANsMappingRemoteA | read-write | current | NID Series card MSTI Configuration: MSTI Mapping - MSTI 7 |
| 1.3.6.1.4.1.4756.20.501.20.1.969 | ColumnnidMSTI8VLANsMappingRemoteA | read-write | current | NID Series card MSTI Configuration: MSTI Mapping - MSTI 8 |
| 1.3.6.1.4.1.4756.20.501.20.1.970 | ColumnnidMSTI9VLANsMappingRemoteA | read-write | current | NID Series card MSTI Configuration: MSTI Mapping - MSTI 9 |
| 1.3.6.1.4.1.4756.20.501.20.1.971 | ColumnnidMSTI10VLANsMappingRemoteA | read-write | current | NID Series card MSTI Configuration: MSTI Mapping - MSTI 10 |
| 1.3.6.1.4.1.4756.20.501.20.1.972 | ColumnnidMSTI11VLANsMappingRemoteA | read-write | current | NID Series card MSTI Configuration: MSTI Mapping - MSTI 11 |
| 1.3.6.1.4.1.4756.20.501.20.1.973 | ColumnnidMSTI12VLANsMappingRemoteA | read-write | current | NID Series card MSTI Configuration: MSTI Mapping - MSTI 12 |
| 1.3.6.1.4.1.4756.20.501.20.1.974 | ColumnnidMSTI13VLANsMappingRemoteA | read-write | current | NID Series card MSTI Configuration: MSTI Mapping - MSTI 13 |
| 1.3.6.1.4.1.4756.20.501.20.1.975 | ColumnnidMSTI14VLANsMappingRemoteA | read-write | current | NID Series card MSTI Configuration: MSTI Mapping - MSTI 14 |
| 1.3.6.1.4.1.4756.20.501.20.1.976 | ColumnnidMSTI15VLANsMappingRemoteA | read-write | current | NID Series card MSTI Configuration: MSTI Mapping - MSTI 15 |
| 1.3.6.1.4.1.4756.20.501.20.1.977 | ColumnnidCISTAggregatedSTPEnabledRemoteA | read-write | current | NID Series card STP CIST Port Configuration: CIST Aggregated Port Configuration - STP Enabled |
| 1.3.6.1.4.1.4756.20.501.20.1.978 | ColumnnidCISTAggregatedPathCostRemoteA | read-write | current | NID Series card STP CIST Port Configuration: CIST Aggregated Port Configuration - Path Cost Valid values are in the range 0 to 200000000. Setting 0 means Auto … |
| 1.3.6.1.4.1.4756.20.501.20.1.979 | ColumnnidCISTAggregatedPriorityRemoteA | read-write | current | NID Series card STP CIST Port Configuration: CIST Aggregated Port Configuration - Priority |
| 1.3.6.1.4.1.4756.20.501.20.1.980 | ColumnnidCISTAggregatedAdminEdgeRemoteA | read-write | current | NID Series card STP CIST Port Configuration: CIST Aggregated Port Configuration - STP Enabled 0: Non-edge 1: Edge |
| 1.3.6.1.4.1.4756.20.501.20.1.981 | ColumnnidCISTAggregatedAutoEdgeRemoteA | read-write | current | NID Series card STP CIST Port Configuration: CIST Aggregated Port Configuration - Auto Edge 0: Non-edge 1: Edge |
| 1.3.6.1.4.1.4756.20.501.20.1.982 | ColumnnidCISTAggregatedRestrictedRoleRemoteA | read-write | current | NID Series card STP CIST Port Configuration: CIST Aggregated Port Configuration - Restricted Role 0: Non-edge 1: Edge |
| 1.3.6.1.4.1.4756.20.501.20.1.983 | ColumnnidCISTAggregatedRestrictedTCNRemoteA | read-write | current | NID Series card STP CIST Port Configuration: CIST Aggregated Port Configuration - Restricted TCN 0: Non-edge 1: Edge |
| 1.3.6.1.4.1.4756.20.501.20.1.984 | ColumnnidCISTAggregatedBPDUGuardRemoteA | read-write | current | NID Series card STP CIST Port Configuration: CIST Aggregated Port Configuration - BPDU Guard 0: Non-edge 1: Edge |
| 1.3.6.1.4.1.4756.20.501.20.1.985 | ColumnnidCISTAggregatedPointToPointRemoteA | read-write | current | NID Series card STP CIST Port Configuration: CIST Aggregated Port Configuration - Point-to-point 0: Forced True 1: Forced False 2: Auto |
| 1.3.6.1.4.1.4756.20.501.20.1.986 | ColumnnidCISTPort1STPEnabledRemoteA | read-write | current | NID Series card STP CIST Port Configuration: CIST Normal Port1 Configuration - STP Enabled |
| 1.3.6.1.4.1.4756.20.501.20.1.987 | ColumnnidCISTPort1PathCostRemoteA | read-write | current | NID Series card STP CIST Port Configuration: CIST Normal Port1 Configuration - Path Cost Valid values are in the range 0 to 200000000. Setting 0 means Auto pat… |
| 1.3.6.1.4.1.4756.20.501.20.1.988 | ColumnnidCISTPort1PriorityRemoteA | read-write | current | NID Series card STP CIST Port Configuration: CIST Normal Port1 Configuration - Priority |
| 1.3.6.1.4.1.4756.20.501.20.1.989 | ColumnnidCISTPort1AdminEdgeRemoteA | read-write | current | NID Series card STP CIST Port Configuration: CIST Normal Port1 Configuration - STP Enabled 0: Non-edge 1: Edge |
| 1.3.6.1.4.1.4756.20.501.20.1.990 | ColumnnidCISTPort1AutoEdgeRemoteA | read-write | current | NID Series card STP CIST Port Configuration: CIST Normal Port1 Configuration - Auto Edge 0: Non-edge 1: Edge |
| 1.3.6.1.4.1.4756.20.501.20.1.991 | ColumnnidCISTPort1RestrictedRoleRemoteA | read-write | current | NID Series card STP CIST Port Configuration: CIST Normal Port1 Configuration - Restricted Role 0: Non-edge 1: Edge |
| 1.3.6.1.4.1.4756.20.501.20.1.992 | ColumnnidCISTPort1RestrictedTCNRemoteA | read-write | current | NID Series card STP CIST Port Configuration: CIST Normal Port1 Configuration - Restricted TCN 0: Non-edge 1: Edge |
| 1.3.6.1.4.1.4756.20.501.20.1.993 | ColumnnidCISTPort1BPDUGuardRemoteA | read-write | current | NID Series card STP CIST Port Configuration: CIST Normal Port1 Configuration - BPDU Guard 0: Non-edge 1: Edge |
| 1.3.6.1.4.1.4756.20.501.20.1.994 | ColumnnidCISTPort1PointToPointRemoteA | read-write | current | NID Series card STP CIST Port Configuration: CIST Normal Port1 Configuration - Point-to-point 0: Forced True 1: Forced False 2: Auto |
| 1.3.6.1.4.1.4756.20.501.20.1.995 | ColumnnidCISTPort2STPEnabledRemoteA | read-write | current | NID Series card STP CIST Port Configuration: CIST Normal Port2 Configuration - STP Enabled |
| 1.3.6.1.4.1.4756.20.501.20.1.996 | ColumnnidCISTPort2PathCostRemoteA | read-write | current | NID Series card STP CIST Port Configuration: CIST Normal Port2 Configuration - Path Cost Valid values are in the range 0 to 200000000. Setting 0 means Auto pat… |
| 1.3.6.1.4.1.4756.20.501.20.1.997 | ColumnnidCISTPort2PriorityRemoteA | read-write | current | NID Series card STP CIST Port Configuration: CIST Normal Port2 Configuration - Priority |
| 1.3.6.1.4.1.4756.20.501.20.1.998 | ColumnnidCISTPort2AdminEdgeRemoteA | read-write | current | NID Series card STP CIST Port Configuration: CIST Normal Port2 Configuration - STP Enabled 0: Non-edge 1: Edge |
| 1.3.6.1.4.1.4756.20.501.20.1.999 | ColumnnidCISTPort2AutoEdgeRemoteA | read-write | current | NID Series card STP CIST Port Configuration: CIST Normal Port2 Configuration - Auto Edge 0: Non-edge 1: Edge |
| 1.3.6.1.4.1.4756.20.501.20.1.1000 | ColumnnidCISTPort2RestrictedRoleRemoteA | read-write | current | NID Series card STP CIST Port Configuration: CIST Normal Port2 Configuration - Restricted Role 0: Non-edge 1: Edge |
| 1.3.6.1.4.1.4756.20.501.20.1.1001 | ColumnnidCISTPort2RestrictedTCNRemoteA | read-write | current | NID Series card STP CIST Port Configuration: CIST Normal Port2 Configuration - Restricted TCN 0: Non-edge 1: Edge |
| 1.3.6.1.4.1.4756.20.501.20.1.1002 | ColumnnidCISTPort2BPDUGuardRemoteA | read-write | current | NID Series card STP CIST Port Configuration: CIST Normal Port2 Configuration - BPDU Guard 0: Non-edge 1: Edge |
| 1.3.6.1.4.1.4756.20.501.20.1.1003 | ColumnnidCISTPort2PointToPointRemoteA | read-write | current | NID Series card STP CIST Port Configuration: CIST Normal Port2 Configuration - Point-to-point 0: Forced True 1: Forced False 2: Auto |
| 1.3.6.1.4.1.4756.20.501.20.1.1004 | ColumnnidCISTPort3STPEnabledRemoteA | read-write | current | NID Series card STP CIST Port Configuration: CIST Normal Port3 Configuration - STP Enabled |
| 1.3.6.1.4.1.4756.20.501.20.1.1005 | ColumnnidCISTPort3PathCostRemoteA | read-write | current | NID Series card STP CIST Port Configuration: CIST Normal Port3 Configuration - Path Cost Valid values are in the range 0 to 200000000. Setting 0 means Auto pat… |
| 1.3.6.1.4.1.4756.20.501.20.1.1006 | ColumnnidCISTPort3PriorityRemoteA | read-write | current | NID Series card STP CIST Port Configuration: CIST Normal Port3 Configuration - Priority |
| 1.3.6.1.4.1.4756.20.501.20.1.1007 | ColumnnidCISTPort3AdminEdgeRemoteA | read-write | current | NID Series card STP CIST Port Configuration: CIST Normal Port3 Configuration - STP Enabled 0: Non-edge 1: Edge |
| 1.3.6.1.4.1.4756.20.501.20.1.1008 | ColumnnidCISTPort3AutoEdgeRemoteA | read-write | current | NID Series card STP CIST Port Configuration: CIST Normal Port3 Configuration - Auto Edge 0: Non-edge 1: Edge |
| 1.3.6.1.4.1.4756.20.501.20.1.1009 | ColumnnidCISTPort3RestrictedRoleRemoteA | read-write | current | NID Series card STP CIST Port Configuration: CIST Normal Port3 Configuration - Restricted Role 0: Non-edge 1: Edge |
| 1.3.6.1.4.1.4756.20.501.20.1.1010 | ColumnnidCISTPort3RestrictedTCNRemoteA | read-write | current | NID Series card STP CIST Port Configuration: CIST Normal Port3 Configuration - Restricted TCN 0: Non-edge 1: Edge |
| 1.3.6.1.4.1.4756.20.501.20.1.1011 | ColumnnidCISTPort3BPDUGuardRemoteA | read-write | current | NID Series card STP CIST Port Configuration: CIST Normal Port3 Configuration - BPDU Guard 0: Non-edge 1: Edge |
| 1.3.6.1.4.1.4756.20.501.20.1.1012 | ColumnnidCISTPort3PointToPointRemoteA | read-write | current | NID Series card STP CIST Port Configuration: CIST Normal Port3 Configuration - Point-to-point 0: Forced True 1: Forced False 2: Auto |
| 1.3.6.1.4.1.4756.20.501.20.1.1013 | ColumnnidCISTPort4STPEnabledRemoteA | read-write | current | NID Series card STP CIST Port Configuration: CIST Normal Port4 Configuration - STP Enabled |
| 1.3.6.1.4.1.4756.20.501.20.1.1014 | ColumnnidCISTPort4PathCostRemoteA | read-write | current | NID Series card STP CIST Port Configuration: CIST Normal Port4 Configuration - Path Cost Valid values are in the range 0 to 200000000. Setting 0 means Auto pat… |
| 1.3.6.1.4.1.4756.20.501.20.1.1015 | ColumnnidCISTPort4PriorityRemoteA | read-write | current | NID Series card STP CIST Port Configuration: CIST Normal Port4 Configuration - Priority |
| 1.3.6.1.4.1.4756.20.501.20.1.1016 | ColumnnidCISTPort4AdminEdgeRemoteA | read-write | current | NID Series card STP CIST Port Configuration: CIST Normal Port4 Configuration - STP Enabled 0: Non-edge 1: Edge |
| 1.3.6.1.4.1.4756.20.501.20.1.1017 | ColumnnidCISTPort4AutoEdgeRemoteA | read-write | current | NID Series card STP CIST Port Configuration: CIST Normal Port4 Configuration - Auto Edge 0: Non-edge 1: Edge |
| 1.3.6.1.4.1.4756.20.501.20.1.1018 | ColumnnidCISTPort4RestrictedRoleRemoteA | read-write | current | NID Series card STP CIST Port Configuration: CIST Normal Port4 Configuration - Restricted Role 0: Non-edge 1: Edge |
| 1.3.6.1.4.1.4756.20.501.20.1.1019 | ColumnnidCISTPort4RestrictedTCNRemoteA | read-write | current | NID Series card STP CIST Port Configuration: CIST Normal Port4 Configuration - Restricted TCN 0: Non-edge 1: Edge |
| 1.3.6.1.4.1.4756.20.501.20.1.1020 | ColumnnidCISTPort4BPDUGuardRemoteA | read-write | current | NID Series card STP CIST Port Configuration: CIST Normal Port4 Configuration - BPDU Guard 0: Non-edge 1: Edge |
| 1.3.6.1.4.1.4756.20.501.20.1.1021 | ColumnnidCISTPort4PointToPointRemoteA | read-write | current | NID Series card STP CIST Port Configuration: CIST Normal Port4 Configuration - Point-to-point 0: Forced True 1: Forced False 2: Auto |
| 1.3.6.1.4.1.4756.20.501.20.1.1022 | ColumnnidCISTPort5STPEnabledRemoteA | read-write | current | NID Series card STP CIST Port Configuration: CIST Normal Port5 Configuration - STP Enabled |
| 1.3.6.1.4.1.4756.20.501.20.1.1023 | ColumnnidCISTPort5PathCostRemoteA | read-write | current | NID Series card STP CIST Port Configuration: CIST Normal Port5 Configuration - Path Cost Valid values are in the range 0 to 200000000. Setting 0 means Auto pat… |
| 1.3.6.1.4.1.4756.20.501.20.1.1024 | ColumnnidCISTPort5PriorityRemoteA | read-write | current | NID Series card STP CIST Port Configuration: CIST Normal Port5 Configuration - Priority |
| 1.3.6.1.4.1.4756.20.501.20.1.1025 | ColumnnidCISTPort5AdminEdgeRemoteA | read-write | current | NID Series card STP CIST Port Configuration: CIST Normal Port5 Configuration - STP Enabled 0: Non-edge 1: Edge |
| 1.3.6.1.4.1.4756.20.501.20.1.1026 | ColumnnidCISTPort5AutoEdgeRemoteA | read-write | current | NID Series card STP CIST Port Configuration: CIST Normal Port5 Configuration - Auto Edge 0: Non-edge 1: Edge |
| 1.3.6.1.4.1.4756.20.501.20.1.1027 | ColumnnidCISTPort5RestrictedRoleRemoteA | read-write | current | NID Series card STP CIST Port Configuration: CIST Normal Port5 Configuration - Restricted Role 0: Non-edge 1: Edge |
| 1.3.6.1.4.1.4756.20.501.20.1.1028 | ColumnnidCISTPort5RestrictedTCNRemoteA | read-write | current | NID Series card STP CIST Port Configuration: CIST Normal Port5 Configuration - Restricted TCN 0: Non-edge 1: Edge |
| 1.3.6.1.4.1.4756.20.501.20.1.1029 | ColumnnidCISTPort5BPDUGuardRemoteA | read-write | current | NID Series card STP CIST Port Configuration: CIST Normal Port5 Configuration - BPDU Guard 0: Non-edge 1: Edge |
| 1.3.6.1.4.1.4756.20.501.20.1.1030 | ColumnnidCISTPort5PointToPointRemoteA | read-write | current | NID Series card STP CIST Port Configuration: CIST Normal Port5 Configuration - Point-to-point 0: Forced True 1: Forced False 2: Auto |
| 1.3.6.1.4.1.4756.20.501.20.1.1031 | ColumnnidCISTPort6STPEnabledRemoteA | read-write | current | NID Series card STP CIST Port Configuration: CIST Normal Port6 Configuration - STP Enabled |
| 1.3.6.1.4.1.4756.20.501.20.1.1032 | ColumnnidCISTPort6PathCostRemoteA | read-write | current | NID Series card STP CIST Port Configuration: CIST Normal Port6 Configuration - Path Cost Valid values are in the range 0 to 200000000. Setting 0 means Auto pat… |
| 1.3.6.1.4.1.4756.20.501.20.1.1033 | ColumnnidCISTPort6PriorityRemoteA | read-write | current | NID Series card STP CIST Port Configuration: CIST Normal Port6 Configuration - Priority |
| 1.3.6.1.4.1.4756.20.501.20.1.1034 | ColumnnidCISTPort6AdminEdgeRemoteA | read-write | current | NID Series card STP CIST Port Configuration: CIST Normal Port6 Configuration - STP Enabled 0: Non-edge 1: Edge |
| 1.3.6.1.4.1.4756.20.501.20.1.1035 | ColumnnidCISTPort6AutoEdgeRemoteA | read-write | current | NID Series card STP CIST Port Configuration: CIST Normal Port6 Configuration - Auto Edge 0: Non-edge 1: Edge |
| 1.3.6.1.4.1.4756.20.501.20.1.1036 | ColumnnidCISTPort6RestrictedRoleRemoteA | read-write | current | NID Series card STP CIST Port Configuration: CIST Normal Port6 Configuration - Restricted Role 0: Non-edge 1: Edge |
| 1.3.6.1.4.1.4756.20.501.20.1.1037 | ColumnnidCISTPort6RestrictedTCNRemoteA | read-write | current | NID Series card STP CIST Port Configuration: CIST Normal Port6 Configuration - Restricted TCN 0: Non-edge 1: Edge |
| 1.3.6.1.4.1.4756.20.501.20.1.1038 | ColumnnidCISTPort6BPDUGuardRemoteA | read-write | current | NID Series card STP CIST Port Configuration: CIST Normal Port6 Configuration - BPDU Guard 0: Non-edge 1: Edge |
| 1.3.6.1.4.1.4756.20.501.20.1.1039 | ColumnnidCISTPort6PointToPointRemoteA | read-write | current | NID Series card STP CIST Port Configuration: CIST Normal Port6 Configuration - Point-to-point 0: Forced True 1: Forced False 2: Auto |
| 1.3.6.1.4.1.4756.20.501.20.1.1040 | ColumnnidCISTPort7STPEnabledRemoteA | read-write | current | NID Series card STP CIST Port Configuration: CIST Normal Port7 Configuration - STP Enabled |
| 1.3.6.1.4.1.4756.20.501.20.1.1041 | ColumnnidCISTPort7PathCostRemoteA | read-write | current | NID Series card STP CIST Port Configuration: CIST Normal Port7 Configuration - Path Cost Valid values are in the range 0 to 200000000. Setting 0 means Auto pat… |
| 1.3.6.1.4.1.4756.20.501.20.1.1042 | ColumnnidCISTPort7PriorityRemoteA | read-write | current | NID Series card STP CIST Port Configuration: CIST Normal Port7 Configuration - Priority |
| 1.3.6.1.4.1.4756.20.501.20.1.1043 | ColumnnidCISTPort7AdminEdgeRemoteA | read-write | current | NID Series card STP CIST Port Configuration: CIST Normal Port7 Configuration - STP Enabled 0: Non-edge 1: Edge |
| 1.3.6.1.4.1.4756.20.501.20.1.1044 | ColumnnidCISTPort7AutoEdgeRemoteA | read-write | current | NID Series card STP CIST Port Configuration: CIST Normal Port7 Configuration - Auto Edge 0: Non-edge 1: Edge |
| 1.3.6.1.4.1.4756.20.501.20.1.1045 | ColumnnidCISTPort7RestrictedRoleRemoteA | read-write | current | NID Series card STP CIST Port Configuration: CIST Normal Port7 Configuration - Restricted Role 0: Non-edge 1: Edge |
| 1.3.6.1.4.1.4756.20.501.20.1.1046 | ColumnnidCISTPort7RestrictedTCNRemoteA | read-write | current | NID Series card STP CIST Port Configuration: CIST Normal Port7 Configuration - Restricted TCN 0: Non-edge 1: Edge |
| 1.3.6.1.4.1.4756.20.501.20.1.1047 | ColumnnidCISTPort7BPDUGuardRemoteA | read-write | current | NID Series card STP CIST Port Configuration: CIST Normal Port7 Configuration - BPDU Guard 0: Non-edge 1: Edge |
| 1.3.6.1.4.1.4756.20.501.20.1.1048 | ColumnnidCISTPort7PointToPointRemoteA | read-write | current | NID Series card STP CIST Port Configuration: CIST Normal Port7 Configuration - Point-to-point 0: Forced True 1: Forced False 2: Auto |
| 1.3.6.1.4.1.4756.20.501.20.1.1049 | ColumnnidCISTPort8STPEnabledRemoteA | read-write | current | NID Series card STP CIST Port Configuration: CIST Normal Port8 Configuration - STP Enabled |
| 1.3.6.1.4.1.4756.20.501.20.1.1050 | ColumnnidCISTPort8PathCostRemoteA | read-write | current | NID Series card STP CIST Port Configuration: CIST Normal Port8 Configuration - Path Cost Valid values are in the range 0 to 200000000. Setting 0 means Auto pat… |
| 1.3.6.1.4.1.4756.20.501.20.1.1051 | ColumnnidCISTPort8PriorityRemoteA | read-write | current | NID Series card STP CIST Port Configuration: CIST Normal Port8 Configuration - Priority |
| 1.3.6.1.4.1.4756.20.501.20.1.1052 | ColumnnidCISTPort8AdminEdgeRemoteA | read-write | current | NID Series card STP CIST Port Configuration: CIST Normal Port8 Configuration - STP Enabled 0: Non-edge 1: Edge |
| 1.3.6.1.4.1.4756.20.501.20.1.1053 | ColumnnidCISTPort8AutoEdgeRemoteA | read-write | current | NID Series card STP CIST Port Configuration: CIST Normal Port8 Configuration - Auto Edge 0: Non-edge 1: Edge |
| 1.3.6.1.4.1.4756.20.501.20.1.1054 | ColumnnidCISTPort8RestrictedRoleRemoteA | read-write | current | NID Series card STP CIST Port Configuration: CIST Normal Port8 Configuration - Restricted Role 0: Non-edge 1: Edge |
| 1.3.6.1.4.1.4756.20.501.20.1.1055 | ColumnnidCISTPort8RestrictedTCNRemoteA | read-write | current | NID Series card STP CIST Port Configuration: CIST Normal Port8 Configuration - Restricted TCN 0: Non-edge 1: Edge |
| 1.3.6.1.4.1.4756.20.501.20.1.1056 | ColumnnidCISTPort8BPDUGuardRemoteA | read-write | current | NID Series card STP CIST Port Configuration: CIST Normal Port8 Configuration - BPDU Guard 0: Non-edge 1: Edge |
| 1.3.6.1.4.1.4756.20.501.20.1.1057 | ColumnnidCISTPort8PointToPointRemoteA | read-write | current | NID Series card STP CIST Port Configuration: CIST Normal Port8 Configuration - Point-to-point 0: Forced True 1: Forced False 2: Auto |
| 1.3.6.1.4.1.4756.20.501.20.1.1058 | ColumnnidMSTI1AggregatedPathCostRemoteA | read-write | current | NID Series card MSTI Port Configuration: MSTI1 Aggregated Ports Configuration - Path Cost Valid values are in the range 0 to 200000000. Setting 0 means Auto pa… |
| 1.3.6.1.4.1.4756.20.501.20.1.1059 | ColumnnidMSTI1AggregatedPriorityRemoteA | read-write | current | NID Series card MSTI Port Configuration: MSTI1 Aggregated Ports Configuration - Priority |
| 1.3.6.1.4.1.4756.20.501.20.1.1060 | ColumnnidMSTI1Port1PathCostRemoteA | read-write | current | NID Series card MSTI Port Configuration: MSTI1 Normal Port1 Configuration - Path Cost Valid values are in the range 0 to 200000000. Setting 0 means Auto path c… |
| 1.3.6.1.4.1.4756.20.501.20.1.1061 | ColumnnidMSTI1Port1PriorityRemoteA | read-write | current | NID Series card MSTI Port Configuration: MSTI1 Normal Port1 Configuration - Priority |
| 1.3.6.1.4.1.4756.20.501.20.1.1062 | ColumnnidMSTI1Port2PathCostRemoteA | read-write | current | NID Series card MSTI Port Configuration: MSTI1 Normal Port2 Configuration - Path Cost Valid values are in the range 0 to 200000000. Setting 0 means Auto path c… |
| 1.3.6.1.4.1.4756.20.501.20.1.1063 | ColumnnidMSTI1Port2PriorityRemoteA | read-write | current | NID Series card MSTI Port Configuration: MSTI1 Normal Port2 Configuration - Priority |
| 1.3.6.1.4.1.4756.20.501.20.1.1064 | ColumnnidMSTI1Port3PathCostRemoteA | read-write | current | NID Series card MSTI Port Configuration: MSTI1 Normal Port3 Configuration - Path Cost Valid values are in the range 0 to 200000000. Setting 0 means Auto path c… |
| 1.3.6.1.4.1.4756.20.501.20.1.1065 | ColumnnidMSTI1Port3PriorityRemoteA | read-write | current | NID Series card MSTI Port Configuration: MSTI1 Normal Port3 Configuration - Priority |
| 1.3.6.1.4.1.4756.20.501.20.1.1066 | ColumnnidMSTI1Port4PathCostRemoteA | read-write | current | NID Series card MSTI Port Configuration: MSTI1 Normal Port4 Configuration - Path Cost Valid values are in the range 0 to 200000000. Setting 0 means Auto path c… |
| 1.3.6.1.4.1.4756.20.501.20.1.1067 | ColumnnidMSTI1Port4PriorityRemoteA | read-write | current | NID Series card MSTI Port Configuration: MSTI1 Normal Port4 Configuration - Priority |
| 1.3.6.1.4.1.4756.20.501.20.1.1068 | ColumnnidMSTI1Port5PathCostRemoteA | read-write | current | NID Series card MSTI Port Configuration: MSTI1 Normal Port5 Configuration - Path Cost Valid values are in the range 0 to 200000000. Setting 0 means Auto path c… |
| 1.3.6.1.4.1.4756.20.501.20.1.1069 | ColumnnidMSTI1Port5PriorityRemoteA | read-write | current | NID Series card MSTI Port Configuration: MSTI1 Normal Port5 Configuration - Priority |
| 1.3.6.1.4.1.4756.20.501.20.1.1070 | ColumnnidMSTI1Port6PathCostRemoteA | read-write | current | NID Series card MSTI Port Configuration: MSTI1 Normal Port6 Configuration - Path Cost Valid values are in the range 0 to 200000000. Setting 0 means Auto path c… |
| 1.3.6.1.4.1.4756.20.501.20.1.1071 | ColumnnidMSTI1Port6PriorityRemoteA | read-write | current | NID Series card MSTI Port Configuration: MSTI1 Normal Port6 Configuration - Priority |
| 1.3.6.1.4.1.4756.20.501.20.1.1072 | ColumnnidMSTI1Port7PathCostRemoteA | read-write | current | NID Series card MSTI Port Configuration: MSTI1 Normal Port7 Configuration - Path Cost Valid values are in the range 0 to 200000000. Setting 0 means Auto path c… |
| 1.3.6.1.4.1.4756.20.501.20.1.1073 | ColumnnidMSTI1Port7PriorityRemoteA | read-write | current | NID Series card MSTI Port Configuration: MSTI1 Normal Port7 Configuration - Priority |
| 1.3.6.1.4.1.4756.20.501.20.1.1074 | ColumnnidMSTI1Port8PathCostRemoteA | read-write | current | NID Series card MSTI Port Configuration: MSTI1 Normal Port8 Configuration - Path Cost Valid values are in the range 0 to 200000000. Setting 0 means Auto path c… |
| 1.3.6.1.4.1.4756.20.501.20.1.1075 | ColumnnidMSTI1Port8PriorityRemoteA | read-write | current | NID Series card MSTI Port Configuration: MSTI1 Normal Port8 Configuration - Priority |
| 1.3.6.1.4.1.4756.20.501.20.1.1076 | ColumnnidMSTI2AggregatedPathCostRemoteA | read-write | current | NID Series card MSTI Port Configuration: MSTI2 Aggregated Ports Configuration - Path Cost Valid values are in the range 0 to 200000000. Setting 0 means Auto pa… |
| 1.3.6.1.4.1.4756.20.501.20.1.1077 | ColumnnidMSTI2AggregatedPriorityRemoteA | read-write | current | NID Series card MSTI Port Configuration: MSTI2 Aggregated Ports Configuration - Priority |
| 1.3.6.1.4.1.4756.20.501.20.1.1078 | ColumnnidMSTI2Port1PathCostRemoteA | read-write | current | NID Series card MSTI Port Configuration: MSTI2 Normal Port1 Configuration - Path Cost Valid values are in the range 0 to 200000000. Setting 0 means Auto path c… |
| 1.3.6.1.4.1.4756.20.501.20.1.1079 | ColumnnidMSTI2Port1PriorityRemoteA | read-write | current | NID Series card MSTI Port Configuration: MSTI2 Normal Port1 Configuration - Priority |
| 1.3.6.1.4.1.4756.20.501.20.1.1080 | ColumnnidMSTI2Port2PathCostRemoteA | read-write | current | NID Series card MSTI Port Configuration: MSTI2 Normal Port2 Configuration - Path Cost Valid values are in the range 0 to 200000000. Setting 0 means Auto path c… |
| 1.3.6.1.4.1.4756.20.501.20.1.1081 | ColumnnidMSTI2Port2PriorityRemoteA | read-write | current | NID Series card MSTI Port Configuration: MSTI2 Normal Port2 Configuration - Priority |
| 1.3.6.1.4.1.4756.20.501.20.1.1082 | ColumnnidMSTI2Port3PathCostRemoteA | read-write | current | NID Series card MSTI Port Configuration: MSTI2 Normal Port3 Configuration - Path Cost Valid values are in the range 0 to 200000000. Setting 0 means Auto path c… |
| 1.3.6.1.4.1.4756.20.501.20.1.1083 | ColumnnidMSTI2Port3PriorityRemoteA | read-write | current | NID Series card MSTI Port Configuration: MSTI2 Normal Port3 Configuration - Priority |
| 1.3.6.1.4.1.4756.20.501.20.1.1084 | ColumnnidMSTI2Port4PathCostRemoteA | read-write | current | NID Series card MSTI Port Configuration: MSTI2 Normal Port4 Configuration - Path Cost Valid values are in the range 0 to 200000000. Setting 0 means Auto path c… |
| 1.3.6.1.4.1.4756.20.501.20.1.1085 | ColumnnidMSTI2Port4PriorityRemoteA | read-write | current | NID Series card MSTI Port Configuration: MSTI2 Normal Port4 Configuration - Priority |
| 1.3.6.1.4.1.4756.20.501.20.1.1086 | ColumnnidMSTI2Port5PathCostRemoteA | read-write | current | NID Series card MSTI Port Configuration: MSTI2 Normal Port5 Configuration - Path Cost Valid values are in the range 0 to 200000000. Setting 0 means Auto path c… |
| 1.3.6.1.4.1.4756.20.501.20.1.1087 | ColumnnidMSTI2Port5PriorityRemoteA | read-write | current | NID Series card MSTI Port Configuration: MSTI2 Normal Port5 Configuration - Priority |
| 1.3.6.1.4.1.4756.20.501.20.1.1088 | ColumnnidMSTI2Port6PathCostRemoteA | read-write | current | NID Series card MSTI Port Configuration: MSTI2 Normal Port6 Configuration - Path Cost Valid values are in the range 0 to 200000000. Setting 0 means Auto path c… |
| 1.3.6.1.4.1.4756.20.501.20.1.1089 | ColumnnidMSTI2Port6PriorityRemoteA | read-write | current | NID Series card MSTI Port Configuration: MSTI2 Normal Port6 Configuration - Priority |
| 1.3.6.1.4.1.4756.20.501.20.1.1090 | ColumnnidMSTI2Port7PathCostRemoteA | read-write | current | NID Series card MSTI Port Configuration: MSTI2 Normal Port7 Configuration - Path Cost Valid values are in the range 0 to 200000000. Setting 0 means Auto path c… |
| 1.3.6.1.4.1.4756.20.501.20.1.1091 | ColumnnidMSTI2Port7PriorityRemoteA | read-write | current | NID Series card MSTI Port Configuration: MSTI2 Normal Port7 Configuration - Priority |
| 1.3.6.1.4.1.4756.20.501.20.1.1092 | ColumnnidMSTI2Port8PathCostRemoteA | read-write | current | NID Series card MSTI Port Configuration: MSTI2 Normal Port8 Configuration - Path Cost Valid values are in the range 0 to 200000000. Setting 0 means Auto path c… |
| 1.3.6.1.4.1.4756.20.501.20.1.1093 | ColumnnidMSTI2Port8PriorityRemoteA | read-write | current | NID Series card MSTI Port Configuration: MSTI2 Normal Port8 Configuration - Priority |
| 1.3.6.1.4.1.4756.20.501.20.1.1094 | ColumnnidMSTI3AggregatedPathCostRemoteA | read-write | current | NID Series card MSTI Port Configuration: MSTI3 Aggregated Ports Configuration - Path Cost Valid values are in the range 0 to 200000000. Setting 0 means Auto pa… |
| 1.3.6.1.4.1.4756.20.501.20.1.1095 | ColumnnidMSTI3AggregatedPriorityRemoteA | read-write | current | NID Series card MSTI Port Configuration: MSTI3 Aggregated Ports Configuration - Priority |
| 1.3.6.1.4.1.4756.20.501.20.1.1096 | ColumnnidMSTI3Port1PathCostRemoteA | read-write | current | NID Series card MSTI Port Configuration: MSTI3 Normal Port1 Configuration - Path Cost Valid values are in the range 0 to 200000000. Setting 0 means Auto path c… |
| 1.3.6.1.4.1.4756.20.501.20.1.1097 | ColumnnidMSTI3Port1PriorityRemoteA | read-write | current | NID Series card MSTI Port Configuration: MSTI3 Normal Port1 Configuration - Priority |
| 1.3.6.1.4.1.4756.20.501.20.1.1098 | ColumnnidMSTI3Port2PathCostRemoteA | read-write | current | NID Series card MSTI Port Configuration: MSTI3 Normal Port2 Configuration - Path Cost Valid values are in the range 0 to 200000000. Setting 0 means Auto path c… |
| 1.3.6.1.4.1.4756.20.501.20.1.1099 | ColumnnidMSTI3Port2PriorityRemoteA | read-write | current | NID Series card MSTI Port Configuration: MSTI3 Normal Port2 Configuration - Priority |
| 1.3.6.1.4.1.4756.20.501.20.1.1100 | ColumnnidMSTI3Port3PathCostRemoteA | read-write | current | NID Series card MSTI Port Configuration: MSTI1 Normal Port3 Configuration - Path Cost Valid values are in the range 0 to 200000000. Setting 0 means Auto path c… |
| 1.3.6.1.4.1.4756.20.501.20.1.1101 | ColumnnidMSTI3Port3PriorityRemoteA | read-write | current | NID Series card MSTI Port Configuration: MSTI3 Normal Port3 Configuration - Priority |
| 1.3.6.1.4.1.4756.20.501.20.1.1102 | ColumnnidMSTI3Port4PathCostRemoteA | read-write | current | NID Series card MSTI Port Configuration: MSTI3 Normal Port4 Configuration - Path Cost Valid values are in the range 0 to 200000000. Setting 0 means Auto path c… |
| 1.3.6.1.4.1.4756.20.501.20.1.1103 | ColumnnidMSTI3Port4PriorityRemoteA | read-write | current | NID Series card MSTI Port Configuration: MSTI3 Normal Port4 Configuration - Priority |
| 1.3.6.1.4.1.4756.20.501.20.1.1104 | ColumnnidMSTI3Port5PathCostRemoteA | read-write | current | NID Series card MSTI Port Configuration: MSTI3 Normal Port5 Configuration - Path Cost Valid values are in the range 0 to 200000000. Setting 0 means Auto path c… |
| 1.3.6.1.4.1.4756.20.501.20.1.1105 | ColumnnidMSTI3Port5PriorityRemoteA | read-write | current | NID Series card MSTI Port Configuration: MSTI3 Normal Port5 Configuration - Priority |
| 1.3.6.1.4.1.4756.20.501.20.1.1106 | ColumnnidMSTI3Port6PathCostRemoteA | read-write | current | NID Series card MSTI Port Configuration: MSTI3 Normal Port6 Configuration - Path Cost Valid values are in the range 0 to 200000000. Setting 0 means Auto path c… |
| 1.3.6.1.4.1.4756.20.501.20.1.1107 | ColumnnidMSTI3Port6PriorityRemoteA | read-write | current | NID Series card MSTI Port Configuration: MSTI3 Normal Port6 Configuration - Priority |
| 1.3.6.1.4.1.4756.20.501.20.1.1108 | ColumnnidMSTI3Port7PathCostRemoteA | read-write | current | NID Series card MSTI Port Configuration: MSTI3 Normal Port7 Configuration - Path Cost Valid values are in the range 0 to 200000000. Setting 0 means Auto path c… |
| 1.3.6.1.4.1.4756.20.501.20.1.1109 | ColumnnidMSTI3Port7PriorityRemoteA | read-write | current | NID Series card MSTI Port Configuration: MSTI3 Normal Port7 Configuration - Priority |
| 1.3.6.1.4.1.4756.20.501.20.1.1110 | ColumnnidMSTI3Port8PathCostRemoteA | read-write | current | NID Series card MSTI Port Configuration: MSTI3 Normal Port8 Configuration - Path Cost Valid values are in the range 0 to 200000000. Setting 0 means Auto path c… |
| 1.3.6.1.4.1.4756.20.501.20.1.1111 | ColumnnidMSTI3Port8PriorityRemoteA | read-write | current | NID Series card MSTI Port Configuration: MSTI3 Normal Port8 Configuration - Priority |
| 1.3.6.1.4.1.4756.20.501.20.1.1112 | ColumnnidMSTI4AggregatedPathCostRemoteA | read-write | current | NID Series card MSTI Port Configuration: MSTI4 Aggregated Ports Configuration - Path Cost Valid values are in the range 0 to 200000000. Setting 0 means Auto pa… |
| 1.3.6.1.4.1.4756.20.501.20.1.1113 | ColumnnidMSTI4AggregatedPriorityRemoteA | read-write | current | NID Series card MSTI Port Configuration: MSTI4 Aggregated Ports Configuration - Priority |
| 1.3.6.1.4.1.4756.20.501.20.1.1114 | ColumnnidMSTI4Port1PathCostRemoteA | read-write | current | NID Series card MSTI Port Configuration: MSTI4 Normal Port1 Configuration - Path Cost Valid values are in the range 0 to 200000000. Setting 0 means Auto path c… |
| 1.3.6.1.4.1.4756.20.501.20.1.1115 | ColumnnidMSTI4Port1PriorityRemoteA | read-write | current | NID Series card MSTI Port Configuration: MSTI4 Normal Port1 Configuration - Priority |
| 1.3.6.1.4.1.4756.20.501.20.1.1116 | ColumnnidMSTI4Port2PathCostRemoteA | read-write | current | NID Series card MSTI Port Configuration: MSTI4 Normal Port2 Configuration - Path Cost Valid values are in the range 0 to 200000000. Setting 0 means Auto path c… |
| 1.3.6.1.4.1.4756.20.501.20.1.1117 | ColumnnidMSTI4Port2PriorityRemoteA | read-write | current | NID Series card MSTI Port Configuration: MSTI4 Normal Port2 Configuration - Priority |
| 1.3.6.1.4.1.4756.20.501.20.1.1118 | ColumnnidMSTI4Port3PathCostRemoteA | read-write | current | NID Series card MSTI Port Configuration: MSTI1 Normal Port3 Configuration - Path Cost Valid values are in the range 0 to 200000000. Setting 0 means Auto path c… |
| 1.3.6.1.4.1.4756.20.501.20.1.1119 | ColumnnidMSTI4Port3PriorityRemoteA | read-write | current | NID Series card MSTI Port Configuration: MSTI4 Normal Port3 Configuration - Priority |
| 1.3.6.1.4.1.4756.20.501.20.1.1120 | ColumnnidMSTI4Port4PathCostRemoteA | read-write | current | NID Series card MSTI Port Configuration: MSTI4 Normal Port4 Configuration - Path Cost Valid values are in the range 0 to 200000000. Setting 0 means Auto path c… |
| 1.3.6.1.4.1.4756.20.501.20.1.1121 | ColumnnidMSTI4Port4PriorityRemoteA | read-write | current | NID Series card MSTI Port Configuration: MSTI4 Normal Port4 Configuration - Priority |
| 1.3.6.1.4.1.4756.20.501.20.1.1122 | ColumnnidMSTI4Port5PathCostRemoteA | read-write | current | NID Series card MSTI Port Configuration: MSTI4 Normal Port5 Configuration - Path Cost Valid values are in the range 0 to 200000000. Setting 0 means Auto path c… |
| 1.3.6.1.4.1.4756.20.501.20.1.1123 | ColumnnidMSTI4Port5PriorityRemoteA | read-write | current | NID Series card MSTI Port Configuration: MSTI4 Normal Port5 Configuration - Priority |
| 1.3.6.1.4.1.4756.20.501.20.1.1124 | ColumnnidMSTI4Port6PathCostRemoteA | read-write | current | NID Series card MSTI Port Configuration: MSTI4 Normal Port4 Configuration - Path Cost Valid values are in the range 0 to 200000000. Setting 0 means Auto path c… |
| 1.3.6.1.4.1.4756.20.501.20.1.1125 | ColumnnidMSTI4Port6PriorityRemoteA | read-write | current | NID Series card MSTI Port Configuration: MSTI4 Normal Port6 Configuration - Priority |
| 1.3.6.1.4.1.4756.20.501.20.1.1126 | ColumnnidMSTI4Port7PathCostRemoteA | read-write | current | NID Series card MSTI Port Configuration: MSTI4 Normal Port7 Configuration - Path Cost Valid values are in the range 0 to 200000000. Setting 0 means Auto path c… |
| 1.3.6.1.4.1.4756.20.501.20.1.1127 | ColumnnidMSTI4Port7PriorityRemoteA | read-write | current | NID Series card MSTI Port Configuration: MSTI4 Normal Port7 Configuration - Priority |
| 1.3.6.1.4.1.4756.20.501.20.1.1128 | ColumnnidMSTI4Port8PathCostRemoteA | read-write | current | NID Series card MSTI Port Configuration: MSTI4 Normal Port8 Configuration - Path Cost Valid values are in the range 0 to 200000000. Setting 0 means Auto path c… |
| 1.3.6.1.4.1.4756.20.501.20.1.1129 | ColumnnidMSTI4Port8PriorityRemoteA | read-write | current | NID Series card MSTI Port Configuration: MSTI4 Normal Port8 Configuration - Priority |
| 1.3.6.1.4.1.4756.20.501.20.1.1130 | ColumnnidMSTI5AggregatedPathCostRemoteA | read-write | current | NID Series card MSTI Port Configuration: MSTI5 Aggregated Ports Configuration - Path Cost Valid values are in the range 0 to 200000000. Setting 0 means Auto pa… |
| 1.3.6.1.4.1.4756.20.501.20.1.1131 | ColumnnidMSTI5AggregatedPriorityRemoteA | read-write | current | NID Series card MSTI Port Configuration: MSTI5 Aggregated Ports Configuration - Priority |
| 1.3.6.1.4.1.4756.20.501.20.1.1132 | ColumnnidMSTI5Port1PathCostRemoteA | read-write | current | NID Series card MSTI Port Configuration: MSTI5 Normal Port1 Configuration - Path Cost Valid values are in the range 0 to 200000000. Setting 0 means Auto path c… |
| 1.3.6.1.4.1.4756.20.501.20.1.1133 | ColumnnidMSTI5Port1PriorityRemoteA | read-write | current | NID Series card MSTI Port Configuration: MSTI5 Normal Port1 Configuration - Priority |
| 1.3.6.1.4.1.4756.20.501.20.1.1134 | ColumnnidMSTI5Port2PathCostRemoteA | read-write | current | NID Series card MSTI Port Configuration: MSTI5 Normal Port2 Configuration - Path Cost Valid values are in the range 0 to 200000000. Setting 0 means Auto path c… |
| 1.3.6.1.4.1.4756.20.501.20.1.1135 | ColumnnidMSTI5Port2PriorityRemoteA | read-write | current | NID Series card MSTI Port Configuration: MSTI5 Normal Port2 Configuration - Priority |
| 1.3.6.1.4.1.4756.20.501.20.1.1136 | ColumnnidMSTI5Port3PathCostRemoteA | read-write | current | NID Series card MSTI Port Configuration: MSTI5 Normal Port3 Configuration - Path Cost Valid values are in the range 0 to 200000000. Setting 0 means Auto path c… |
| 1.3.6.1.4.1.4756.20.501.20.1.1137 | ColumnnidMSTI5Port3PriorityRemoteA | read-write | current | NID Series card MSTI Port Configuration: MSTI5 Normal Port3 Configuration - Priority |
| 1.3.6.1.4.1.4756.20.501.20.1.1138 | ColumnnidMSTI5Port4PathCostRemoteA | read-write | current | NID Series card MSTI Port Configuration: MSTI5 Normal Port4 Configuration - Path Cost Valid values are in the range 0 to 200000000. Setting 0 means Auto path c… |
| 1.3.6.1.4.1.4756.20.501.20.1.1139 | ColumnnidMSTI5Port4PriorityRemoteA | read-write | current | NID Series card MSTI Port Configuration: MSTI5 Normal Port4 Configuration - Priority |
| 1.3.6.1.4.1.4756.20.501.20.1.1140 | ColumnnidMSTI5Port5PathCostRemoteA | read-write | current | NID Series card MSTI Port Configuration: MSTI5 Normal Port5 Configuration - Path Cost Valid values are in the range 0 to 200000000. Setting 0 means Auto path c… |
| 1.3.6.1.4.1.4756.20.501.20.1.1141 | ColumnnidMSTI5Port5PriorityRemoteA | read-write | current | NID Series card MSTI Port Configuration: MSTI5 Normal Port5 Configuration - Priority |
| 1.3.6.1.4.1.4756.20.501.20.1.1142 | ColumnnidMSTI5Port6PathCostRemoteA | read-write | current | NID Series card MSTI Port Configuration: MSTI5 Normal Port6 Configuration - Path Cost Valid values are in the range 0 to 200000000. Setting 0 means Auto path c… |
| 1.3.6.1.4.1.4756.20.501.20.1.1143 | ColumnnidMSTI5Port6PriorityRemoteA | read-write | current | NID Series card MSTI Port Configuration: MSTI5 Normal Port6 Configuration - Priority |
| 1.3.6.1.4.1.4756.20.501.20.1.1144 | ColumnnidMSTI5Port7PathCostRemoteA | read-write | current | NID Series card MSTI Port Configuration: MSTI5 Normal Port7 Configuration - Path Cost Valid values are in the range 0 to 200000000. Setting 0 means Auto path c… |
| 1.3.6.1.4.1.4756.20.501.20.1.1145 | ColumnnidMSTI5Port7PriorityRemoteA | read-write | current | NID Series card MSTI Port Configuration: MSTI5 Normal Port7 Configuration - Priority |
| 1.3.6.1.4.1.4756.20.501.20.1.1146 | ColumnnidMSTI5Port8PathCostRemoteA | read-write | current | NID Series card MSTI Port Configuration: MSTI5 Normal Port8 Configuration - Path Cost Valid values are in the range 0 to 200000000. Setting 0 means Auto path c… |
| 1.3.6.1.4.1.4756.20.501.20.1.1147 | ColumnnidMSTI5Port8PriorityRemoteA | read-write | current | NID Series card MSTI Port Configuration: MSTI5 Normal Port8 Configuration - Priority |
| 1.3.6.1.4.1.4756.20.501.20.1.1148 | ColumnnidMSTI6AggregatedPathCostRemoteA | read-write | current | NID Series card MSTI Port Configuration: MSTI6 Aggregated Ports Configuration - Path Cost Valid values are in the range 0 to 200000000. Setting 0 means Auto pa… |
| 1.3.6.1.4.1.4756.20.501.20.1.1149 | ColumnnidMSTI6AggregatedPriorityRemoteA | read-write | current | NID Series card MSTI Port Configuration: MSTI6 Aggregated Ports Configuration - Priority |
| 1.3.6.1.4.1.4756.20.501.20.1.1150 | ColumnnidMSTI6Port1PathCostRemoteA | read-write | current | NID Series card MSTI Port Configuration: MSTI6 Normal Port1 Configuration - Path Cost Valid values are in the range 0 to 200000000. Setting 0 means Auto path c… |
| 1.3.6.1.4.1.4756.20.501.20.1.1151 | ColumnnidMSTI6Port1PriorityRemoteA | read-write | current | NID Series card MSTI Port Configuration: MSTI6 Normal Port1 Configuration - Priority |
| 1.3.6.1.4.1.4756.20.501.20.1.1152 | ColumnnidMSTI6Port2PathCostRemoteA | read-write | current | NID Series card MSTI Port Configuration: MSTI6 Normal Port2 Configuration - Path Cost Valid values are in the range 0 to 200000000. Setting 0 means Auto path c… |
| 1.3.6.1.4.1.4756.20.501.20.1.1153 | ColumnnidMSTI6Port2PriorityRemoteA | read-write | current | NID Series card MSTI Port Configuration: MSTI6 Normal Port2 Configuration - Priority |
| 1.3.6.1.4.1.4756.20.501.20.1.1154 | ColumnnidMSTI6Port3PathCostRemoteA | read-write | current | NID Series card MSTI Port Configuration: MSTI6 Normal Port3 Configuration - Path Cost Valid values are in the range 0 to 200000000. Setting 0 means Auto path c… |
| 1.3.6.1.4.1.4756.20.501.20.1.1155 | ColumnnidMSTI6Port3PriorityRemoteA | read-write | current | NID Series card MSTI Port Configuration: MSTI6 Normal Port3 Configuration - Priority |
| 1.3.6.1.4.1.4756.20.501.20.1.1156 | ColumnnidMSTI6Port4PathCostRemoteA | read-write | current | NID Series card MSTI Port Configuration: MSTI6 Normal Port4 Configuration - Path Cost Valid values are in the range 0 to 200000000. Setting 0 means Auto path c… |
| 1.3.6.1.4.1.4756.20.501.20.1.1157 | ColumnnidMSTI6Port4PriorityRemoteA | read-write | current | NID Series card MSTI Port Configuration: MSTI6 Normal Port4 Configuration - Priority |
| 1.3.6.1.4.1.4756.20.501.20.1.1158 | ColumnnidMSTI6Port5PathCostRemoteA | read-write | current | NID Series card MSTI Port Configuration: MSTI6 Normal Port5 Configuration - Path Cost Valid values are in the range 0 to 200000000. Setting 0 means Auto path c… |
| 1.3.6.1.4.1.4756.20.501.20.1.1159 | ColumnnidMSTI6Port5PriorityRemoteA | read-write | current | NID Series card MSTI Port Configuration: MSTI6 Normal Port6 Configuration - Priority |
| 1.3.6.1.4.1.4756.20.501.20.1.1160 | ColumnnidMSTI6Port6PathCostRemoteA | read-write | current | NID Series card MSTI Port Configuration: MSTI6 Normal Port6 Configuration - Path Cost Valid values are in the range 0 to 200000000. Setting 0 means Auto path c… |
| 1.3.6.1.4.1.4756.20.501.20.1.1161 | ColumnnidMSTI6Port6PriorityRemoteA | read-write | current | NID Series card MSTI Port Configuration: MSTI6 Normal Port6 Configuration - Priority |
| 1.3.6.1.4.1.4756.20.501.20.1.1162 | ColumnnidMSTI6Port7PathCostRemoteA | read-write | current | NID Series card MSTI Port Configuration: MSTI6 Normal Port7 Configuration - Path Cost Valid values are in the range 0 to 200000000. Setting 0 means Auto path c… |
| 1.3.6.1.4.1.4756.20.501.20.1.1163 | ColumnnidMSTI6Port7PriorityRemoteA | read-write | current | NID Series card MSTI Port Configuration: MSTI6 Normal Port6 Configuration - Priority |
| 1.3.6.1.4.1.4756.20.501.20.1.1164 | ColumnnidMSTI6Port8PathCostRemoteA | read-write | current | NID Series card MSTI Port Configuration: MSTI6 Normal Port8 Configuration - Path Cost Valid values are in the range 0 to 200000000. Setting 0 means Auto path c… |
| 1.3.6.1.4.1.4756.20.501.20.1.1165 | ColumnnidMSTI6Port8PriorityRemoteA | read-write | current | NID Series card MSTI Port Configuration: MSTI6 Normal Port8 Configuration - Priority |
| 1.3.6.1.4.1.4756.20.501.20.1.1166 | ColumnnidMSTI7AggregatedPathCostRemoteA | read-write | current | NID Series card MSTI Port Configuration: MSTI7 Aggregated Ports Configuration - Path Cost Valid values are in the range 0 to 200000000. Setting 0 means Auto pa… |
| 1.3.6.1.4.1.4756.20.501.20.1.1167 | ColumnnidMSTI7AggregatedPriorityRemoteA | read-write | current | NID Series card MSTI Port Configuration: MSTI7 Aggregated Ports Configuration - Priority |
| 1.3.6.1.4.1.4756.20.501.20.1.1168 | ColumnnidMSTI7Port1PathCostRemoteA | read-write | current | NID Series card MSTI Port Configuration: MSTI1 Normal Port1 Configuration - Path Cost Valid values are in the range 0 to 200000000. Setting 0 means Auto path c… |
| 1.3.6.1.4.1.4756.20.501.20.1.1169 | ColumnnidMSTI7Port1PriorityRemoteA | read-write | current | NID Series card MSTI Port Configuration: MSTI1 Normal Port1 Configuration - Priority |
| 1.3.6.1.4.1.4756.20.501.20.1.1170 | ColumnnidMSTI7Port2PathCostRemoteA | read-write | current | NID Series card MSTI Port Configuration: MSTI7 Normal Port2 Configuration - Path Cost Valid values are in the range 0 to 200000000. Setting 0 means Auto path c… |
| 1.3.6.1.4.1.4756.20.501.20.1.1171 | ColumnnidMSTI7Port2PriorityRemoteA | read-write | current | NID Series card MSTI Port Configuration: MSTI7 Normal Port2 Configuration - Priority |
| 1.3.6.1.4.1.4756.20.501.20.1.1172 | ColumnnidMSTI7Port3PathCostRemoteA | read-write | current | NID Series card MSTI Port Configuration: MSTI7 Normal Port3 Configuration - Path Cost Valid values are in the range 0 to 200000000. Setting 0 means Auto path c… |
| 1.3.6.1.4.1.4756.20.501.20.1.1173 | ColumnnidMSTI7Port3PriorityRemoteA | read-write | current | NID Series card MSTI Port Configuration: MSTI7 Normal Port3 Configuration - Priority |
| 1.3.6.1.4.1.4756.20.501.20.1.1174 | ColumnnidMSTI7Port4PathCostRemoteA | read-write | current | NID Series card MSTI Port Configuration: MSTI7 Normal Port4 Configuration - Path Cost Valid values are in the range 0 to 200000000. Setting 0 means Auto path c… |
| 1.3.6.1.4.1.4756.20.501.20.1.1175 | ColumnnidMSTI7Port4PriorityRemoteA | read-write | current | NID Series card MSTI Port Configuration: MSTI7 Normal Port4 Configuration - Priority |
| 1.3.6.1.4.1.4756.20.501.20.1.1176 | ColumnnidMSTI7Port5PathCostRemoteA | read-write | current | NID Series card MSTI Port Configuration: MSTI7 Normal Port5 Configuration - Path Cost Valid values are in the range 0 to 200000000. Setting 0 means Auto path c… |
| 1.3.6.1.4.1.4756.20.501.20.1.1177 | ColumnnidMSTI7Port5PriorityRemoteA | read-write | current | NID Series card MSTI Port Configuration: MSTI7 Normal Port5 Configuration - Priority |
| 1.3.6.1.4.1.4756.20.501.20.1.1178 | ColumnnidMSTI7Port6PathCostRemoteA | read-write | current | NID Series card MSTI Port Configuration: MSTI7 Normal Port6 Configuration - Path Cost Valid values are in the range 0 to 200000000. Setting 0 means Auto path c… |
| 1.3.6.1.4.1.4756.20.501.20.1.1179 | ColumnnidMSTI7Port6PriorityRemoteA | read-write | current | NID Series card MSTI Port Configuration: MSTI7 Normal Port6 Configuration - Priority |
| 1.3.6.1.4.1.4756.20.501.20.1.1180 | ColumnnidMSTI7Port7PathCostRemoteA | read-write | current | NID Series card MSTI Port Configuration: MSTI7 Normal Port7 Configuration - Path Cost Valid values are in the range 0 to 200000000. Setting 0 means Auto path c… |
| 1.3.6.1.4.1.4756.20.501.20.1.1181 | ColumnnidMSTI7Port7PriorityRemoteA | read-write | current | NID Series card MSTI Port Configuration: MSTI7 Normal Port7 Configuration - Priority |
| 1.3.6.1.4.1.4756.20.501.20.1.1182 | ColumnnidMSTI7Port8PathCostRemoteA | read-write | current | NID Series card MSTI Port Configuration: MSTI7 Normal Port8 Configuration - Path Cost Valid values are in the range 0 to 200000000. Setting 0 means Auto path c… |
| 1.3.6.1.4.1.4756.20.501.20.1.1183 | ColumnnidMSTI7Port8PriorityRemoteA | read-write | current | NID Series card MSTI Port Configuration: MSTI7 Normal Port8 Configuration - Priority |
| 1.3.6.1.4.1.4756.20.501.20.1.1184 | ColumnnidMSTI8AggregatedPathCostRemoteA | read-write | current | NID Series card MSTI Port Configuration: MSTI8 Aggregated Ports Configuration - Path Cost Valid values are in the range 0 to 200000000. Setting 0 means Auto pa… |
| 1.3.6.1.4.1.4756.20.501.20.1.1185 | ColumnnidMSTI8AggregatedPriorityRemoteA | read-write | current | NID Series card MSTI Port Configuration: MSTI7 Aggregated Ports Configuration - Priority |
| 1.3.6.1.4.1.4756.20.501.20.1.1186 | ColumnnidMSTI8Port1PathCostRemoteA | read-write | current | NID Series card MSTI Port Configuration: MSTI8 Normal Port1 Configuration - Path Cost Valid values are in the range 0 to 200000000. Setting 0 means Auto path c… |
| 1.3.6.1.4.1.4756.20.501.20.1.1187 | ColumnnidMSTI8Port1PriorityRemoteA | read-write | current | NID Series card MSTI Port Configuration: MSTI8 Normal Port1 Configuration - Priority |
| 1.3.6.1.4.1.4756.20.501.20.1.1188 | ColumnnidMSTI8Port2PathCostRemoteA | read-write | current | NID Series card MSTI Port Configuration: MSTI8 Normal Port2 Configuration - Path Cost Valid values are in the range 0 to 200000000. Setting 0 means Auto path c… |
| 1.3.6.1.4.1.4756.20.501.20.1.1189 | ColumnnidMSTI8Port2PriorityRemoteA | read-write | current | NID Series card MSTI Port Configuration: MSTI8 Normal Port2 Configuration - Priority |
| 1.3.6.1.4.1.4756.20.501.20.1.1190 | ColumnnidMSTI8Port3PathCostRemoteA | read-write | current | NID Series card MSTI Port Configuration: MSTI8 Normal Port3 Configuration - Path Cost Valid values are in the range 0 to 200000000. Setting 0 means Auto path c… |
| 1.3.6.1.4.1.4756.20.501.20.1.1191 | ColumnnidMSTI8Port3PriorityRemoteA | read-write | current | NID Series card MSTI Port Configuration: MSTI8 Normal Port3 Configuration - Priority |
| 1.3.6.1.4.1.4756.20.501.20.1.1192 | ColumnnidMSTI8Port4PathCostRemoteA | read-write | current | NID Series card MSTI Port Configuration: MSTI8 Normal Port4 Configuration - Path Cost Valid values are in the range 0 to 200000000. Setting 0 means Auto path c… |
| 1.3.6.1.4.1.4756.20.501.20.1.1193 | ColumnnidMSTI8Port4PriorityRemoteA | read-write | current | NID Series card MSTI Port Configuration: MSTI8 Normal Port4 Configuration - Priority |
| 1.3.6.1.4.1.4756.20.501.20.1.1194 | ColumnnidMSTI8Port5PathCostRemoteA | read-write | current | NID Series card MSTI Port Configuration: MSTI8 Normal Port5 Configuration - Path Cost Valid values are in the range 0 to 200000000. Setting 0 means Auto path c… |
| 1.3.6.1.4.1.4756.20.501.20.1.1195 | ColumnnidMSTI8Port5PriorityRemoteA | read-write | current | NID Series card MSTI Port Configuration: MSTI8 Normal Port5 Configuration - Priority |
| 1.3.6.1.4.1.4756.20.501.20.1.1196 | ColumnnidMSTI8Port6PathCostRemoteA | read-write | current | NID Series card MSTI Port Configuration: MSTI8 Normal Port6 Configuration - Path Cost Valid values are in the range 0 to 200000000. Setting 0 means Auto path c… |
| 1.3.6.1.4.1.4756.20.501.20.1.1197 | ColumnnidMSTI8Port6PriorityRemoteA | read-write | current | NID Series card MSTI Port Configuration: MSTI8 Normal Port6 Configuration - Priority |
| 1.3.6.1.4.1.4756.20.501.20.1.1198 | ColumnnidMSTI8Port7PathCostRemoteA | read-write | current | NID Series card MSTI Port Configuration: MSTI8 Normal Port7 Configuration - Path Cost Valid values are in the range 0 to 200000000. Setting 0 means Auto path c… |
| 1.3.6.1.4.1.4756.20.501.20.1.1199 | ColumnnidMSTI8Port7PriorityRemoteA | read-write | current | NID Series card MSTI Port Configuration: MSTI8 Normal Port7 Configuration - Priority |
| 1.3.6.1.4.1.4756.20.501.20.1.1200 | ColumnnidMSTI8Port8PathCostRemoteA | read-write | current | NID Series card MSTI Port Configuration: MSTI7 Normal Port8 Configuration - Path Cost Valid values are in the range 0 to 200000000. Setting 0 means Auto path c… |
| 1.3.6.1.4.1.4756.20.501.20.1.1201 | ColumnnidMSTI8Port8PriorityRemoteA | read-write | current | NID Series card MSTI Port Configuration: MSTI8 Normal Port8 Configuration - Priority |
| 1.3.6.1.4.1.4756.20.501.20.1.1202 | ColumnnidMSTI9AggregatedPathCostRemoteA | read-write | current | NID Series card MSTI Port Configuration: MSTI9 Aggregated Ports Configuration - Path Cost Valid values are in the range 0 to 200000000. Setting 0 means Auto pa… |
| 1.3.6.1.4.1.4756.20.501.20.1.1203 | ColumnnidMSTI9AggregatedPriorityRemoteA | read-write | current | NID Series card MSTI Port Configuration: MSTI9 Aggregated Ports Configuration - Priority |
| 1.3.6.1.4.1.4756.20.501.20.1.1204 | ColumnnidMSTI9Port1PathCostRemoteA | read-write | current | NID Series card MSTI Port Configuration: MSTI9 Normal Port1 Configuration - Path Cost Valid values are in the range 0 to 200000000. Setting 0 means Auto path c… |
| 1.3.6.1.4.1.4756.20.501.20.1.1205 | ColumnnidMSTI9Port1PriorityRemoteA | read-write | current | NID Series card MSTI Port Configuration: MSTI9 Normal Port1 Configuration - Priority |
| 1.3.6.1.4.1.4756.20.501.20.1.1206 | ColumnnidMSTI9Port2PathCostRemoteA | read-write | current | NID Series card MSTI Port Configuration: MSTI9 Normal Port2 Configuration - Path Cost Valid values are in the range 0 to 200000000. Setting 0 means Auto path c… |
| 1.3.6.1.4.1.4756.20.501.20.1.1207 | ColumnnidMSTI9Port2PriorityRemoteA | read-write | current | NID Series card MSTI Port Configuration: MSTI8 Normal Port2 Configuration - Priority |
| 1.3.6.1.4.1.4756.20.501.20.1.1208 | ColumnnidMSTI9Port3PathCostRemoteA | read-write | current | NID Series card MSTI Port Configuration: MSTI8 Normal Port3 Configuration - Path Cost Valid values are in the range 0 to 200000000. Setting 0 means Auto path c… |
| 1.3.6.1.4.1.4756.20.501.20.1.1209 | ColumnnidMSTI9Port3PriorityRemoteA | read-write | current | NID Series card MSTI Port Configuration: MSTI9 Normal Port3 Configuration - Priority |
| 1.3.6.1.4.1.4756.20.501.20.1.1210 | ColumnnidMSTI9Port4PathCostRemoteA | read-write | current | NID Series card MSTI Port Configuration: MSTI9 Normal Port4 Configuration - Path Cost Valid values are in the range 0 to 200000000. Setting 0 means Auto path c… |
| 1.3.6.1.4.1.4756.20.501.20.1.1211 | ColumnnidMSTI9Port4PriorityRemoteA | read-write | current | NID Series card MSTI Port Configuration: MSTI9 Normal Port4 Configuration - Priority |
| 1.3.6.1.4.1.4756.20.501.20.1.1212 | ColumnnidMSTI9Port5PathCostRemoteA | read-write | current | NID Series card MSTI Port Configuration: MSTI9 Normal Port5 Configuration - Path Cost Valid values are in the range 0 to 200000000. Setting 0 means Auto path c… |
| 1.3.6.1.4.1.4756.20.501.20.1.1213 | ColumnnidMSTI9Port5PriorityRemoteA | read-write | current | NID Series card MSTI Port Configuration: MSTI9 Normal Port5 Configuration - Priority |
| 1.3.6.1.4.1.4756.20.501.20.1.1214 | ColumnnidMSTI9Port6PathCostRemoteA | read-write | current | NID Series card MSTI Port Configuration: MSTI9 Normal Port6 Configuration - Path Cost Valid values are in the range 0 to 200000000. Setting 0 means Auto path c… |
| 1.3.6.1.4.1.4756.20.501.20.1.1215 | ColumnnidMSTI9Port6PriorityRemoteA | read-write | current | NID Series card MSTI Port Configuration: MSTI9 Normal Port6 Configuration - Priority |
| 1.3.6.1.4.1.4756.20.501.20.1.1216 | ColumnnidMSTI9Port7PathCostRemoteA | read-write | current | NID Series card MSTI Port Configuration: MSTI9 Normal Port7 Configuration - Path Cost Valid values are in the range 0 to 200000000. Setting 0 means Auto path c… |
| 1.3.6.1.4.1.4756.20.501.20.1.1217 | ColumnnidMSTI9Port7PriorityRemoteA | read-write | current | NID Series card MSTI Port Configuration: MSTI9 Normal Port7 Configuration - Priority |
| 1.3.6.1.4.1.4756.20.501.20.1.1218 | ColumnnidMSTI9Port8PathCostRemoteA | read-write | current | NID Series card MSTI Port Configuration: MSTI8 Normal Port8 Configuration - Path Cost Valid values are in the range 0 to 200000000. Setting 0 means Auto path c… |
| 1.3.6.1.4.1.4756.20.501.20.1.1219 | ColumnnidMSTI9Port8PriorityRemoteA | read-write | current | NID Series card MSTI Port Configuration: MSTI9 Normal Port8 Configuration - Priority |
| 1.3.6.1.4.1.4756.20.501.20.1.1220 | ColumnnidMSTI10AggregatedPathCostRemoteA | read-write | current | NID Series card MSTI Port Configuration: MSTI10 Aggregated Ports Configuration - Path Cost Valid values are in the range 0 to 200000000. Setting 0 means Auto p… |
| 1.3.6.1.4.1.4756.20.501.20.1.1221 | ColumnnidMSTI10AggregatedPriorityRemoteA | read-write | current | NID Series card MSTI Port Configuration: MSTI10 Aggregated Ports Configuration - Priority |
| 1.3.6.1.4.1.4756.20.501.20.1.1222 | ColumnnidMSTI10Port1PathCostRemoteA | read-write | current | NID Series card MSTI Port Configuration: MSTI10 Normal Port1 Configuration - Path Cost Valid values are in the range 0 to 200000000. Setting 0 means Auto path … |
| 1.3.6.1.4.1.4756.20.501.20.1.1223 | ColumnnidMSTI10Port1PriorityRemoteA | read-write | current | NID Series card MSTI Port Configuration: MSTI10 Normal Port1 Configuration - Priority |
| 1.3.6.1.4.1.4756.20.501.20.1.1224 | ColumnnidMSTI10Port2PathCostRemoteA | read-write | current | NID Series card MSTI Port Configuration: MSTI10 Normal Port2 Configuration - Path Cost Valid values are in the range 0 to 200000000. Setting 0 means Auto path … |
| 1.3.6.1.4.1.4756.20.501.20.1.1225 | ColumnnidMSTI10Port2PriorityRemoteA | read-write | current | NID Series card MSTI Port Configuration: MSTI8 Normal Port2 Configuration - Priority |
| 1.3.6.1.4.1.4756.20.501.20.1.1226 | ColumnnidMSTI10Port3PathCostRemoteA | read-write | current | NID Series card MSTI Port Configuration: MSTI8 Normal Port3 Configuration - Path Cost Valid values are in the range 0 to 200000000. Setting 0 means Auto path c… |
| 1.3.6.1.4.1.4756.20.501.20.1.1227 | ColumnnidMSTI10Port3PriorityRemoteA | read-write | current | NID Series card MSTI Port Configuration: MSTI10 Normal Port3 Configuration - Priority |
| 1.3.6.1.4.1.4756.20.501.20.1.1228 | ColumnnidMSTI10Port4PathCostRemoteA | read-write | current | NID Series card MSTI Port Configuration: MSTI10 Normal Port4 Configuration - Path Cost Valid values are in the range 0 to 200000000. Setting 0 means Auto path … |
| 1.3.6.1.4.1.4756.20.501.20.1.1229 | ColumnnidMSTI10Port4PriorityRemoteA | read-write | current | NID Series card MSTI Port Configuration: MSTI10 Normal Port4 Configuration - Priority |
| 1.3.6.1.4.1.4756.20.501.20.1.1230 | ColumnnidMSTI10Port5PathCostRemoteA | read-write | current | NID Series card MSTI Port Configuration: MSTI10 Normal Port5 Configuration - Path Cost Valid values are in the range 0 to 200000000. Setting 0 means Auto path … |
| 1.3.6.1.4.1.4756.20.501.20.1.1231 | ColumnnidMSTI10Port5PriorityRemoteA | read-write | current | NID Series card MSTI Port Configuration: MSTI10 Normal Port5 Configuration - Priority |
| 1.3.6.1.4.1.4756.20.501.20.1.1232 | ColumnnidMSTI10Port6PathCostRemoteA | read-write | current | NID Series card MSTI Port Configuration: MSTI10 Normal Port6 Configuration - Path Cost Valid values are in the range 0 to 200000000. Setting 0 means Auto path … |
| 1.3.6.1.4.1.4756.20.501.20.1.1233 | ColumnnidMSTI10Port6PriorityRemoteA | read-write | current | NID Series card MSTI Port Configuration: MSTI10 Normal Port6 Configuration - Priority |
| 1.3.6.1.4.1.4756.20.501.20.1.1234 | ColumnnidMSTI10Port7PathCostRemoteA | read-write | current | NID Series card MSTI Port Configuration: MSTI10 Normal Port7 Configuration - Path Cost Valid values are in the range 0 to 200000000. Setting 0 means Auto path … |
| 1.3.6.1.4.1.4756.20.501.20.1.1235 | ColumnnidMSTI10Port7PriorityRemoteA | read-write | current | NID Series card MSTI Port Configuration: MSTI10 Normal Port7 Configuration - Priority |
| 1.3.6.1.4.1.4756.20.501.20.1.1236 | ColumnnidMSTI10Port8PathCostRemoteA | read-write | current | NID Series card MSTI Port Configuration: MSTI8 Normal Port8 Configuration - Path Cost Valid values are in the range 0 to 200000000. Setting 0 means Auto path c… |
| 1.3.6.1.4.1.4756.20.501.20.1.1237 | ColumnnidMSTI10Port8PriorityRemoteA | read-write | current | NID Series card MSTI Port Configuration: MSTI10 Normal Port8 Configuration - Priority |
| 1.3.6.1.4.1.4756.20.501.20.1.1238 | ColumnnidMSTI11AggregatedPathCostRemoteA | read-write | current | NID Series card MSTI Port Configuration: MSTI11 Aggregated Ports Configuration - Path Cost Valid values are in the range 0 to 200000000. Setting 0 means Auto p… |
| 1.3.6.1.4.1.4756.20.501.20.1.1239 | ColumnnidMSTI11AggregatedPriorityRemoteA | read-write | current | NID Series card MSTI Port Configuration: MSTI11 Aggregated Ports Configuration - Priority |
| 1.3.6.1.4.1.4756.20.501.20.1.1240 | ColumnnidMSTI11Port1PathCostRemoteA | read-write | current | NID Series card MSTI Port Configuration: MSTI11 Normal Port1 Configuration - Path Cost Valid values are in the range 0 to 200000000. Setting 0 means Auto path … |
| 1.3.6.1.4.1.4756.20.501.20.1.1241 | ColumnnidMSTI11Port1PriorityRemoteA | read-write | current | NID Series card MSTI Port Configuration: MSTI11 Normal Port1 Configuration - Priority |
| 1.3.6.1.4.1.4756.20.501.20.1.1242 | ColumnnidMSTI11Port2PathCostRemoteA | read-write | current | NID Series card MSTI Port Configuration: MSTI11 Normal Port2 Configuration - Path Cost Valid values are in the range 0 to 200000000. Setting 0 means Auto path … |
| 1.3.6.1.4.1.4756.20.501.20.1.1243 | ColumnnidMSTI11Port2PriorityRemoteA | read-write | current | NID Series card MSTI Port Configuration: MSTI8 Normal Port2 Configuration - Priority |
| 1.3.6.1.4.1.4756.20.501.20.1.1244 | ColumnnidMSTI11Port3PathCostRemoteA | read-write | current | NID Series card MSTI Port Configuration: MSTI8 Normal Port3 Configuration - Path Cost Valid values are in the range 0 to 200000000. Setting 0 means Auto path c… |
| 1.3.6.1.4.1.4756.20.501.20.1.1245 | ColumnnidMSTI11Port3PriorityRemoteA | read-write | current | NID Series card MSTI Port Configuration: MSTI11 Normal Port3 Configuration - Priority |
| 1.3.6.1.4.1.4756.20.501.20.1.1246 | ColumnnidMSTI11Port4PathCostRemoteA | read-write | current | NID Series card MSTI Port Configuration: MSTI11 Normal Port4 Configuration - Path Cost Valid values are in the range 0 to 200000000. Setting 0 means Auto path … |
| 1.3.6.1.4.1.4756.20.501.20.1.1247 | ColumnnidMSTI11Port4PriorityRemoteA | read-write | current | NID Series card MSTI Port Configuration: MSTI11 Normal Port4 Configuration - Priority |
| 1.3.6.1.4.1.4756.20.501.20.1.1248 | ColumnnidMSTI11Port5PathCostRemoteA | read-write | current | NID Series card MSTI Port Configuration: MSTI11 Normal Port5 Configuration - Path Cost Valid values are in the range 0 to 200000000. Setting 0 means Auto path … |
| 1.3.6.1.4.1.4756.20.501.20.1.1249 | ColumnnidMSTI11Port5PriorityRemoteA | read-write | current | NID Series card MSTI Port Configuration: MSTI11 Normal Port5 Configuration - Priority |
| 1.3.6.1.4.1.4756.20.501.20.1.1250 | ColumnnidMSTI11Port6PathCostRemoteA | read-write | current | NID Series card MSTI Port Configuration: MSTI11 Normal Port6 Configuration - Path Cost Valid values are in the range 0 to 200000000. Setting 0 means Auto path … |
| 1.3.6.1.4.1.4756.20.501.20.1.1251 | ColumnnidMSTI11Port6PriorityRemoteA | read-write | current | NID Series card MSTI Port Configuration: MSTI11 Normal Port6 Configuration - Priority |
| 1.3.6.1.4.1.4756.20.501.20.1.1252 | ColumnnidMSTI11Port7PathCostRemoteA | read-write | current | NID Series card MSTI Port Configuration: MSTI11 Normal Port7 Configuration - Path Cost Valid values are in the range 0 to 200000000. Setting 0 means Auto path … |
| 1.3.6.1.4.1.4756.20.501.20.1.1253 | ColumnnidMSTI11Port7PriorityRemoteA | read-write | current | NID Series card MSTI Port Configuration: MSTI11 Normal Port7 Configuration - Priority |
| 1.3.6.1.4.1.4756.20.501.20.1.1254 | ColumnnidMSTI11Port8PathCostRemoteA | read-write | current | NID Series card MSTI Port Configuration: MSTI8 Normal Port8 Configuration - Path Cost Valid values are in the range 0 to 200000000. Setting 0 means Auto path c… |
| 1.3.6.1.4.1.4756.20.501.20.1.1255 | ColumnnidMSTI11Port8PriorityRemoteA | read-write | current | NID Series card MSTI Port Configuration: MSTI11 Normal Port8 Configuration - Priority |
| 1.3.6.1.4.1.4756.20.501.20.1.1256 | ColumnnidMSTI12AggregatedPathCostRemoteA | read-write | current | NID Series card MSTI Port Configuration: MSTI12 Aggregated Ports Configuration - Path Cost Valid values are in the range 0 to 200000000. Setting 0 means Auto p… |
| 1.3.6.1.4.1.4756.20.501.20.1.1257 | ColumnnidMSTI12AggregatedPriorityRemoteA | read-write | current | NID Series card MSTI Port Configuration: MSTI12 Aggregated Ports Configuration - Priority |
| 1.3.6.1.4.1.4756.20.501.20.1.1258 | ColumnnidMSTI12Port1PathCostRemoteA | read-write | current | NID Series card MSTI Port Configuration: MSTI12 Normal Port1 Configuration - Path Cost Valid values are in the range 0 to 200000000. Setting 0 means Auto path … |
| 1.3.6.1.4.1.4756.20.501.20.1.1259 | ColumnnidMSTI12Port1PriorityRemoteA | read-write | current | NID Series card MSTI Port Configuration: MSTI12 Normal Port1 Configuration - Priority |
| 1.3.6.1.4.1.4756.20.501.20.1.1260 | ColumnnidMSTI12Port2PathCostRemoteA | read-write | current | NID Series card MSTI Port Configuration: MSTI12 Normal Port2 Configuration - Path Cost Valid values are in the range 0 to 200000000. Setting 0 means Auto path … |
| 1.3.6.1.4.1.4756.20.501.20.1.1261 | ColumnnidMSTI12Port2PriorityRemoteA | read-write | current | NID Series card MSTI Port Configuration: MSTI8 Normal Port2 Configuration - Priority |
| 1.3.6.1.4.1.4756.20.501.20.1.1262 | ColumnnidMSTI12Port3PathCostRemoteA | read-write | current | NID Series card MSTI Port Configuration: MSTI8 Normal Port3 Configuration - Path Cost Valid values are in the range 0 to 200000000. Setting 0 means Auto path c… |
| 1.3.6.1.4.1.4756.20.501.20.1.1263 | ColumnnidMSTI12Port3PriorityRemoteA | read-write | current | NID Series card MSTI Port Configuration: MSTI12 Normal Port3 Configuration - Priority |
| 1.3.6.1.4.1.4756.20.501.20.1.1264 | ColumnnidMSTI12Port4PathCostRemoteA | read-write | current | NID Series card MSTI Port Configuration: MSTI12 Normal Port4 Configuration - Path Cost Valid values are in the range 0 to 200000000. Setting 0 means Auto path … |
| 1.3.6.1.4.1.4756.20.501.20.1.1265 | ColumnnidMSTI12Port4PriorityRemoteA | read-write | current | NID Series card MSTI Port Configuration: MSTI12 Normal Port4 Configuration - Priority |
| 1.3.6.1.4.1.4756.20.501.20.1.1266 | ColumnnidMSTI12Port5PathCostRemoteA | read-write | current | NID Series card MSTI Port Configuration: MSTI12 Normal Port5 Configuration - Path Cost Valid values are in the range 0 to 200000000. Setting 0 means Auto path … |
| 1.3.6.1.4.1.4756.20.501.20.1.1267 | ColumnnidMSTI12Port5PriorityRemoteA | read-write | current | NID Series card MSTI Port Configuration: MSTI12 Normal Port5 Configuration - Priority |
| 1.3.6.1.4.1.4756.20.501.20.1.1268 | ColumnnidMSTI12Port6PathCostRemoteA | read-write | current | NID Series card MSTI Port Configuration: MSTI12 Normal Port6 Configuration - Path Cost Valid values are in the range 0 to 200000000. Setting 0 means Auto path … |
| 1.3.6.1.4.1.4756.20.501.20.1.1269 | ColumnnidMSTI12Port6PriorityRemoteA | read-write | current | NID Series card MSTI Port Configuration: MSTI12 Normal Port6 Configuration - Priority |
| 1.3.6.1.4.1.4756.20.501.20.1.1270 | ColumnnidMSTI12Port7PathCostRemoteA | read-write | current | NID Series card MSTI Port Configuration: MSTI12 Normal Port7 Configuration - Path Cost Valid values are in the range 0 to 200000000. Setting 0 means Auto path … |
| 1.3.6.1.4.1.4756.20.501.20.1.1271 | ColumnnidMSTI12Port7PriorityRemoteA | read-write | current | NID Series card MSTI Port Configuration: MSTI12 Normal Port7 Configuration - Priority |
| 1.3.6.1.4.1.4756.20.501.20.1.1272 | ColumnnidMSTI12Port8PathCostRemoteA | read-write | current | NID Series card MSTI Port Configuration: MSTI8 Normal Port8 Configuration - Path Cost Valid values are in the range 0 to 200000000. Setting 0 means Auto path c… |
| 1.3.6.1.4.1.4756.20.501.20.1.1273 | ColumnnidMSTI12Port8PriorityRemoteA | read-write | current | NID Series card MSTI Port Configuration: MSTI12 Normal Port8 Configuration - Priority |
| 1.3.6.1.4.1.4756.20.501.20.1.1274 | ColumnnidMSTI13AggregatedPathCostRemoteA | read-write | current | NID Series card MSTI Port Configuration: MSTI13 Aggregated Ports Configuration - Path Cost Valid values are in the range 0 to 200000000. Setting 0 means Auto p… |
| 1.3.6.1.4.1.4756.20.501.20.1.1275 | ColumnnidMSTI13AggregatedPriorityRemoteA | read-write | current | NID Series card MSTI Port Configuration: MSTI13 Aggregated Ports Configuration - Priority |
| 1.3.6.1.4.1.4756.20.501.20.1.1276 | ColumnnidMSTI13Port1PathCostRemoteA | read-write | current | NID Series card MSTI Port Configuration: MSTI13 Normal Port1 Configuration - Path Cost Valid values are in the range 0 to 200000000. Setting 0 means Auto path … |
| 1.3.6.1.4.1.4756.20.501.20.1.1277 | ColumnnidMSTI13Port1PriorityRemoteA | read-write | current | NID Series card MSTI Port Configuration: MSTI13 Normal Port1 Configuration - Priority |
| 1.3.6.1.4.1.4756.20.501.20.1.1278 | ColumnnidMSTI13Port2PathCostRemoteA | read-write | current | NID Series card MSTI Port Configuration: MSTI13 Normal Port2 Configuration - Path Cost Valid values are in the range 0 to 200000000. Setting 0 means Auto path … |
| 1.3.6.1.4.1.4756.20.501.20.1.1279 | ColumnnidMSTI13Port2PriorityRemoteA | read-write | current | NID Series card MSTI Port Configuration: MSTI8 Normal Port2 Configuration - Priority |
| 1.3.6.1.4.1.4756.20.501.20.1.1280 | ColumnnidMSTI13Port3PathCostRemoteA | read-write | current | NID Series card MSTI Port Configuration: MSTI8 Normal Port3 Configuration - Path Cost Valid values are in the range 0 to 200000000. Setting 0 means Auto path c… |
| 1.3.6.1.4.1.4756.20.501.20.1.1281 | ColumnnidMSTI13Port3PriorityRemoteA | read-write | current | NID Series card MSTI Port Configuration: MSTI13 Normal Port3 Configuration - Priority |
| 1.3.6.1.4.1.4756.20.501.20.1.1282 | ColumnnidMSTI13Port4PathCostRemoteA | read-write | current | NID Series card MSTI Port Configuration: MSTI13 Normal Port4 Configuration - Path Cost Valid values are in the range 0 to 200000000. Setting 0 means Auto path … |
| 1.3.6.1.4.1.4756.20.501.20.1.1283 | ColumnnidMSTI13Port4PriorityRemoteA | read-write | current | NID Series card MSTI Port Configuration: MSTI13 Normal Port4 Configuration - Priority |
| 1.3.6.1.4.1.4756.20.501.20.1.1284 | ColumnnidMSTI13Port5PathCostRemoteA | read-write | current | NID Series card MSTI Port Configuration: MSTI13 Normal Port5 Configuration - Path Cost Valid values are in the range 0 to 200000000. Setting 0 means Auto path … |
| 1.3.6.1.4.1.4756.20.501.20.1.1285 | ColumnnidMSTI13Port5PriorityRemoteA | read-write | current | NID Series card MSTI Port Configuration: MSTI13 Normal Port5 Configuration - Priority |
| 1.3.6.1.4.1.4756.20.501.20.1.1286 | ColumnnidMSTI13Port6PathCostRemoteA | read-write | current | NID Series card MSTI Port Configuration: MSTI13 Normal Port6 Configuration - Path Cost Valid values are in the range 0 to 200000000. Setting 0 means Auto path … |
| 1.3.6.1.4.1.4756.20.501.20.1.1287 | ColumnnidMSTI13Port6PriorityRemoteA | read-write | current | NID Series card MSTI Port Configuration: MSTI13 Normal Port6 Configuration - Priority |
| 1.3.6.1.4.1.4756.20.501.20.1.1288 | ColumnnidMSTI13Port7PathCostRemoteA | read-write | current | NID Series card MSTI Port Configuration: MSTI13 Normal Port7 Configuration - Path Cost Valid values are in the range 0 to 200000000. Setting 0 means Auto path … |
| 1.3.6.1.4.1.4756.20.501.20.1.1289 | ColumnnidMSTI13Port7PriorityRemoteA | read-write | current | NID Series card MSTI Port Configuration: MSTI13 Normal Port7 Configuration - Priority |
| 1.3.6.1.4.1.4756.20.501.20.1.1290 | ColumnnidMSTI13Port8PathCostRemoteA | read-write | current | NID Series card MSTI Port Configuration: MSTI8 Normal Port8 Configuration - Path Cost Valid values are in the range 0 to 200000000. Setting 0 means Auto path c… |
| 1.3.6.1.4.1.4756.20.501.20.1.1291 | ColumnnidMSTI13Port8PriorityRemoteA | read-write | current | NID Series card MSTI Port Configuration: MSTI13 Normal Port8 Configuration - Priority |
| 1.3.6.1.4.1.4756.20.501.20.1.1292 | ColumnnidMSTI14AggregatedPathCostRemoteA | read-write | current | NID Series card MSTI Port Configuration: MSTI14 Aggregated Ports Configuration - Path Cost Valid values are in the range 0 to 200000000. Setting 0 means Auto p… |
| 1.3.6.1.4.1.4756.20.501.20.1.1293 | ColumnnidMSTI14AggregatedPriorityRemoteA | read-write | current | NID Series card MSTI Port Configuration: MSTI14 Aggregated Ports Configuration - Priority |
| 1.3.6.1.4.1.4756.20.501.20.1.1294 | ColumnnidMSTI14Port1PathCostRemoteA | read-write | current | NID Series card MSTI Port Configuration: MSTI14 Normal Port1 Configuration - Path Cost Valid values are in the range 0 to 200000000. Setting 0 means Auto path … |
| 1.3.6.1.4.1.4756.20.501.20.1.1295 | ColumnnidMSTI14Port1PriorityRemoteA | read-write | current | NID Series card MSTI Port Configuration: MSTI14 Normal Port1 Configuration - Priority |
| 1.3.6.1.4.1.4756.20.501.20.1.1296 | ColumnnidMSTI14Port2PathCostRemoteA | read-write | current | NID Series card MSTI Port Configuration: MSTI14 Normal Port2 Configuration - Path Cost Valid values are in the range 0 to 200000000. Setting 0 means Auto path … |
| 1.3.6.1.4.1.4756.20.501.20.1.1297 | ColumnnidMSTI14Port2PriorityRemoteA | read-write | current | NID Series card MSTI Port Configuration: MSTI8 Normal Port2 Configuration - Priority |
| 1.3.6.1.4.1.4756.20.501.20.1.1298 | ColumnnidMSTI14Port3PathCostRemoteA | read-write | current | NID Series card MSTI Port Configuration: MSTI8 Normal Port3 Configuration - Path Cost Valid values are in the range 0 to 200000000. Setting 0 means Auto path c… |
| 1.3.6.1.4.1.4756.20.501.20.1.1299 | ColumnnidMSTI14Port3PriorityRemoteA | read-write | current | NID Series card MSTI Port Configuration: MSTI14 Normal Port3 Configuration - Priority |
| 1.3.6.1.4.1.4756.20.501.20.1.1300 | ColumnnidMSTI14Port4PathCostRemoteA | read-write | current | NID Series card MSTI Port Configuration: MSTI14 Normal Port4 Configuration - Path Cost Valid values are in the range 0 to 200000000. Setting 0 means Auto path … |
| 1.3.6.1.4.1.4756.20.501.20.1.1301 | ColumnnidMSTI14Port4PriorityRemoteA | read-write | current | NID Series card MSTI Port Configuration: MSTI14 Normal Port4 Configuration - Priority |
| 1.3.6.1.4.1.4756.20.501.20.1.1302 | ColumnnidMSTI14Port5PathCostRemoteA | read-write | current | NID Series card MSTI Port Configuration: MSTI14 Normal Port5 Configuration - Path Cost Valid values are in the range 0 to 200000000. Setting 0 means Auto path … |
| 1.3.6.1.4.1.4756.20.501.20.1.1303 | ColumnnidMSTI14Port5PriorityRemoteA | read-write | current | NID Series card MSTI Port Configuration: MSTI14 Normal Port5 Configuration - Priority |
| 1.3.6.1.4.1.4756.20.501.20.1.1304 | ColumnnidMSTI14Port6PathCostRemoteA | read-write | current | NID Series card MSTI Port Configuration: MSTI14 Normal Port6 Configuration - Path Cost Valid values are in the range 0 to 200000000. Setting 0 means Auto path … |
| 1.3.6.1.4.1.4756.20.501.20.1.1305 | ColumnnidMSTI14Port6PriorityRemoteA | read-write | current | NID Series card MSTI Port Configuration: MSTI14 Normal Port6 Configuration - Priority |
| 1.3.6.1.4.1.4756.20.501.20.1.1306 | ColumnnidMSTI14Port7PathCostRemoteA | read-write | current | NID Series card MSTI Port Configuration: MSTI14 Normal Port7 Configuration - Path Cost Valid values are in the range 0 to 200000000. Setting 0 means Auto path … |
| 1.3.6.1.4.1.4756.20.501.20.1.1307 | ColumnnidMSTI14Port7PriorityRemoteA | read-write | current | NID Series card MSTI Port Configuration: MSTI14 Normal Port7 Configuration - Priority |
| 1.3.6.1.4.1.4756.20.501.20.1.1308 | ColumnnidMSTI14Port8PathCostRemoteA | read-write | current | NID Series card MSTI Port Configuration: MSTI8 Normal Port8 Configuration - Path Cost Valid values are in the range 0 to 200000000. Setting 0 means Auto path c… |
| 1.3.6.1.4.1.4756.20.501.20.1.1309 | ColumnnidMSTI14Port8PriorityRemoteA | read-write | current | NID Series card MSTI Port Configuration: MSTI14 Normal Port8 Configuration - Priority |
| 1.3.6.1.4.1.4756.20.501.20.1.1310 | ColumnnidMSTI15AggregatedPathCostRemoteA | read-write | current | NID Series card MSTI Port Configuration: MSTI15 Aggregated Ports Configuration - Path Cost Valid values are in the range 0 to 200000000. Setting 0 means Auto p… |
| 1.3.6.1.4.1.4756.20.501.20.1.1311 | ColumnnidMSTI15AggregatedPriorityRemoteA | read-write | current | NID Series card MSTI Port Configuration: MSTI15 Aggregated Ports Configuration - Priority |
| 1.3.6.1.4.1.4756.20.501.20.1.1312 | ColumnnidMSTI15Port1PathCostRemoteA | read-write | current | NID Series card MSTI Port Configuration: MSTI15 Normal Port1 Configuration - Path Cost Valid values are in the range 0 to 200000000. Setting 0 means Auto path … |
| 1.3.6.1.4.1.4756.20.501.20.1.1313 | ColumnnidMSTI15Port1PriorityRemoteA | read-write | current | NID Series card MSTI Port Configuration: MSTI15 Normal Port1 Configuration - Priority |
| 1.3.6.1.4.1.4756.20.501.20.1.1314 | ColumnnidMSTI15Port2PathCostRemoteA | read-write | current | NID Series card MSTI Port Configuration: MSTI15 Normal Port2 Configuration - Path Cost Valid values are in the range 0 to 200000000. Setting 0 means Auto path … |
| 1.3.6.1.4.1.4756.20.501.20.1.1315 | ColumnnidMSTI15Port2PriorityRemoteA | read-write | current | NID Series card MSTI Port Configuration: MSTI8 Normal Port2 Configuration - Priority |
| 1.3.6.1.4.1.4756.20.501.20.1.1316 | ColumnnidMSTI15Port3PathCostRemoteA | read-write | current | NID Series card MSTI Port Configuration: MSTI8 Normal Port3 Configuration - Path Cost Valid values are in the range 0 to 200000000. Setting 0 means Auto path c… |
| 1.3.6.1.4.1.4756.20.501.20.1.1317 | ColumnnidMSTI15Port3PriorityRemoteA | read-write | current | NID Series card MSTI Port Configuration: MSTI15 Normal Port3 Configuration - Priority |
| 1.3.6.1.4.1.4756.20.501.20.1.1318 | ColumnnidMSTI15Port4PathCostRemoteA | read-write | current | NID Series card MSTI Port Configuration: MSTI15 Normal Port4 Configuration - Path Cost Valid values are in the range 0 to 200000000. Setting 0 means Auto path … |
| 1.3.6.1.4.1.4756.20.501.20.1.1319 | ColumnnidMSTI15Port4PriorityRemoteA | read-write | current | NID Series card MSTI Port Configuration: MSTI15 Normal Port4 Configuration - Priority |
| 1.3.6.1.4.1.4756.20.501.20.1.1320 | ColumnnidMSTI15Port5PathCostRemoteA | read-write | current | NID Series card MSTI Port Configuration: MSTI15 Normal Port5 Configuration - Path Cost Valid values are in the range 0 to 200000000. Setting 0 means Auto path … |
| 1.3.6.1.4.1.4756.20.501.20.1.1321 | ColumnnidMSTI15Port5PriorityRemoteA | read-write | current | NID Series card MSTI Port Configuration: MSTI15 Normal Port5 Configuration - Priority |
| 1.3.6.1.4.1.4756.20.501.20.1.1322 | ColumnnidMSTI15Port6PathCostRemoteA | read-write | current | NID Series card MSTI Port Configuration: MSTI15 Normal Port6 Configuration - Path Cost Valid values are in the range 0 to 200000000. Setting 0 means Auto path … |
| 1.3.6.1.4.1.4756.20.501.20.1.1323 | ColumnnidMSTI15Port6PriorityRemoteA | read-write | current | NID Series card MSTI Port Configuration: MSTI15 Normal Port6 Configuration - Priority |
| 1.3.6.1.4.1.4756.20.501.20.1.1324 | ColumnnidMSTI15Port7PathCostRemoteA | read-write | current | NID Series card MSTI Port Configuration: MSTI15 Normal Port7 Configuration - Path Cost Valid values are in the range 0 to 200000000. Setting 0 means Auto path … |
| 1.3.6.1.4.1.4756.20.501.20.1.1325 | ColumnnidMSTI15Port7PriorityRemoteA | read-write | current | NID Series card MSTI Port Configuration: MSTI15 Normal Port7 Configuration - Priority |
| 1.3.6.1.4.1.4756.20.501.20.1.1326 | ColumnnidMSTI15Port8PathCostRemoteA | read-write | current | NID Series card MSTI Port Configuration: MSTI8 Normal Port8 Configuration - Path Cost Valid values are in the range 0 to 200000000. Setting 0 means Auto path c… |
| 1.3.6.1.4.1.4756.20.501.20.1.1327 | ColumnnidMSTI15Port8PriorityRemoteA | read-write | current | NID Series card MSTI Port Configuration: MSTI15 Normal Port8 Configuration - Priority |
| 1.3.6.1.4.1.4756.20.501.20.1.1328 | ColumnnidCISTBridgeIDRemoteA | read-only | current | NID Series card STP Bridges status: CIST - Bridge ID |
| 1.3.6.1.4.1.4756.20.501.20.1.1329 | ColumnnidCISTRootIDRemoteA | read-only | current | NID Series card STP Bridges status: CIST - Root ID |
| 1.3.6.1.4.1.4756.20.501.20.1.1330 | ColumnnidCISTRootPortRemoteA | read-only | current | NID Series card STP Bridges status: CIST - Root Port |
| 1.3.6.1.4.1.4756.20.501.20.1.1331 | ColumnnidCISTRootCostRemoteA | read-only | current | NID Series card STP Bridges status: CIST - Root Cost |
| 1.3.6.1.4.1.4756.20.501.20.1.1332 | ColumnnidCISTTopologyFlagRemoteA | read-only | current | NID Series card STP Bridges status: CIST - Topology Flag |
| 1.3.6.1.4.1.4756.20.501.20.1.1333 | ColumnnidCISTTopologyChangeLastRemoteA | read-only | current | NID Series card STP Bridges status: CIST - Topology Change Last |
| 1.3.6.1.4.1.4756.20.501.20.1.1334 | ColumnnidMSTI1BridgeIDRemoteA | read-only | current | NID Series card STP Bridges status: MSTI1 - Bridge ID |
| 1.3.6.1.4.1.4756.20.501.20.1.1335 | ColumnnidMSTI1RootIDRemoteA | read-only | current | NID Series card STP Bridges status: MSTI1 - Root ID |
| 1.3.6.1.4.1.4756.20.501.20.1.1336 | ColumnnidMSTI1RootPortRemoteA | read-only | current | NID Series card STP Bridges status: MSTI1 - Root ID |
| 1.3.6.1.4.1.4756.20.501.20.1.1337 | ColumnnidMSTI1RootCostRemoteA | read-only | current | NID Series card STP Bridges status: MSTI1 - Root Cost |
| 1.3.6.1.4.1.4756.20.501.20.1.1338 | ColumnnidMSTI1TopologyFlagRemoteA | read-only | current | NID Series card STP Bridges status: MSTI1 - Topology Flag |
| 1.3.6.1.4.1.4756.20.501.20.1.1339 | ColumnnidMSTI1TopologyChangeLastRemoteA | read-only | current | NID Series card STP Bridges status: MSTI1 - Topology Change Last |
| 1.3.6.1.4.1.4756.20.501.20.1.1340 | ColumnnidMSTI2BridgeIDRemoteA | read-only | current | NID Series card STP Bridges status: MSTI2 - Bridge ID |
| 1.3.6.1.4.1.4756.20.501.20.1.1341 | ColumnnidMSTI2RootIDRemoteA | read-only | current | NID Series card STP Bridges status: MSTI2 - Root ID |
| 1.3.6.1.4.1.4756.20.501.20.1.1342 | ColumnnidMSTI2RootPortRemoteA | read-only | current | NID Series card STP Bridges status: MSTI2 - Root ID |
| 1.3.6.1.4.1.4756.20.501.20.1.1343 | ColumnnidMSTI2RootCostRemoteA | read-only | current | NID Series card STP Bridges status: MSTI2 - Root Cost |
| 1.3.6.1.4.1.4756.20.501.20.1.1344 | ColumnnidMSTI2TopologyFlagRemoteA | read-only | current | NID Series card STP Bridges status: MSTI2 - Topology Flag |
| 1.3.6.1.4.1.4756.20.501.20.1.1345 | ColumnnidMSTI2TopologyChangeLastRemoteA | read-only | current | NID Series card STP Bridges status: MSTI2 - Topology Change Last |
| 1.3.6.1.4.1.4756.20.501.20.1.1346 | ColumnnidMSTI3BridgeIDRemoteA | read-only | current | NID Series card STP Bridges status: MSTI3 - Bridge ID |
| 1.3.6.1.4.1.4756.20.501.20.1.1347 | ColumnnidMSTI3RootIDRemoteA | read-only | current | NID Series card STP Bridges status: MSTI3 - Root ID |
| 1.3.6.1.4.1.4756.20.501.20.1.1348 | ColumnnidMSTI3RootPortRemoteA | read-only | current | NID Series card STP Bridges status: MSTI3 - Root ID |
| 1.3.6.1.4.1.4756.20.501.20.1.1349 | ColumnnidMSTI3RootCostRemoteA | read-only | current | NID Series card STP Bridges status: MSTI3 - Root Cost |
| 1.3.6.1.4.1.4756.20.501.20.1.1350 | ColumnnidMSTI3TopologyFlagRemoteA | read-only | current | NID Series card STP Bridges status: MSTI3 - Topology Flag |
| 1.3.6.1.4.1.4756.20.501.20.1.1351 | ColumnnidMSTI3TopologyChangeLastRemoteA | read-only | current | NID Series card STP Bridges status: MSTI3 - Topology Change Last |
| 1.3.6.1.4.1.4756.20.501.20.1.1352 | ColumnnidMSTI4BridgeIDRemoteA | read-only | current | NID Series card STP Bridges status: MSTI4 - Bridge ID |
| 1.3.6.1.4.1.4756.20.501.20.1.1353 | ColumnnidMSTI4RootIDRemoteA | read-only | current | NID Series card STP Bridges status: MSTI4 - Root ID |
| 1.3.6.1.4.1.4756.20.501.20.1.1354 | ColumnnidMSTI4RootPortRemoteA | read-only | current | NID Series card STP Bridges status: MSTI4 - Root ID |
| 1.3.6.1.4.1.4756.20.501.20.1.1355 | ColumnnidMSTI4RootCostRemoteA | read-only | current | NID Series card STP Bridges status: MSTI4 - Root Cost |
| 1.3.6.1.4.1.4756.20.501.20.1.1356 | ColumnnidMSTI4TopologyFlagRemoteA | read-only | current | NID Series card STP Bridges status: MSTI4 - Topology Flag |
| 1.3.6.1.4.1.4756.20.501.20.1.1357 | ColumnnidMSTI4TopologyChangeLastRemoteA | read-only | current | NID Series card STP Bridges status: MSTI4 - Topology Change Last |
| 1.3.6.1.4.1.4756.20.501.20.1.1358 | ColumnnidMSTI5BridgeIDRemoteA | read-only | current | NID Series card STP Bridges status: MSTI5 - Bridge ID |
| 1.3.6.1.4.1.4756.20.501.20.1.1359 | ColumnnidMSTI5RootIDRemoteA | read-only | current | NID Series card STP Bridges status: MSTI5 - Root ID |
| 1.3.6.1.4.1.4756.20.501.20.1.1360 | ColumnnidMSTI5RootPortRemoteA | read-only | current | NID Series card STP Bridges status: MSTI5 - Root ID |
| 1.3.6.1.4.1.4756.20.501.20.1.1361 | ColumnnidMSTI5RootCostRemoteA | read-only | current | NID Series card STP Bridges status: MSTI5 - Root Cost |
| 1.3.6.1.4.1.4756.20.501.20.1.1362 | ColumnnidMSTI5TopologyFlagRemoteA | read-only | current | NID Series card STP Bridges status: MSTI5 - Topology Flag |
| 1.3.6.1.4.1.4756.20.501.20.1.1363 | ColumnnidMSTI5TopologyChangeLastRemoteA | read-only | current | NID Series card STP Bridges status: MSTI5 - Topology Change Last |
| 1.3.6.1.4.1.4756.20.501.20.1.1364 | ColumnnidMSTI6BridgeIDRemoteA | read-only | current | NID Series card STP Bridges status: MSTI6 - Bridge ID |
| 1.3.6.1.4.1.4756.20.501.20.1.1365 | ColumnnidMSTI6RootIDRemoteA | read-only | current | NID Series card STP Bridges status: MSTI6 - Root ID |
| 1.3.6.1.4.1.4756.20.501.20.1.1366 | ColumnnidMSTI6RootPortRemoteA | read-only | current | NID Series card STP Bridges status: MSTI6 - Root ID |
| 1.3.6.1.4.1.4756.20.501.20.1.1367 | ColumnnidMSTI6RootCostRemoteA | read-only | current | NID Series card STP Bridges status: MSTI6 - Root Cost |
| 1.3.6.1.4.1.4756.20.501.20.1.1368 | ColumnnidMSTI6TopologyFlagRemoteA | read-only | current | NID Series card STP Bridges status: MSTI6 - Topology Flag |
| 1.3.6.1.4.1.4756.20.501.20.1.1369 | ColumnnidMSTI6TopologyChangeLastRemoteA | read-only | current | NID Series card STP Bridges status: MSTI6 - Topology Change Last |
| 1.3.6.1.4.1.4756.20.501.20.1.1370 | ColumnnidMSTI7BridgeIDRemoteA | read-only | current | NID Series card STP Bridges status: MSTI7 - Bridge ID |
| 1.3.6.1.4.1.4756.20.501.20.1.1371 | ColumnnidMSTI7RootIDRemoteA | read-only | current | NID Series card STP Bridges status: MSTI7 - Root ID |
| 1.3.6.1.4.1.4756.20.501.20.1.1372 | ColumnnidMSTI7RootPortRemoteA | read-only | current | NID Series card STP Bridges status: MSTI7 - Root ID |
| 1.3.6.1.4.1.4756.20.501.20.1.1373 | ColumnnidMSTI7RootCostRemoteA | read-only | current | NID Series card STP Bridges status: MSTI7 - Root Cost |
| 1.3.6.1.4.1.4756.20.501.20.1.1374 | ColumnnidMSTI7TopologyFlagRemoteA | read-only | current | NID Series card STP Bridges status: MSTI7 - Topology Flag |
| 1.3.6.1.4.1.4756.20.501.20.1.1375 | ColumnnidMSTI7TopologyChangeLastRemoteA | read-only | current | NID Series card STP Bridges status: MSTI7 - Topology Change Last |
| 1.3.6.1.4.1.4756.20.501.20.1.1376 | ColumnnidMSTI8BridgeIDRemoteA | read-only | current | NID Series card STP Bridges status: MSTI8 - Bridge ID |
| 1.3.6.1.4.1.4756.20.501.20.1.1377 | ColumnnidMSTI8RootIDRemoteA | read-only | current | NID Series card STP Bridges status: MSTI8 - Root ID |
| 1.3.6.1.4.1.4756.20.501.20.1.1378 | ColumnnidMSTI8RootPortRemoteA | read-only | current | NID Series card STP Bridges status: MSTI8 - Root ID |
| 1.3.6.1.4.1.4756.20.501.20.1.1379 | ColumnnidMSTI8RootCostRemoteA | read-only | current | NID Series card STP Bridges status: MSTI8 - Root Cost |
| 1.3.6.1.4.1.4756.20.501.20.1.1380 | ColumnnidMSTI8TopologyFlagRemoteA | read-only | current | NID Series card STP Bridges status: MSTI8 - Topology Flag |
| 1.3.6.1.4.1.4756.20.501.20.1.1381 | ColumnnidMSTI8TopologyChangeLastRemoteA | read-only | current | NID Series card STP Bridges status: MSTI8 - Topology Change Last |
| 1.3.6.1.4.1.4756.20.501.20.1.1382 | ColumnnidMSTI9BridgeIDRemoteA | read-only | current | NID Series card STP Bridges status: MSTI9 - Bridge ID |
| 1.3.6.1.4.1.4756.20.501.20.1.1383 | ColumnnidMSTI9RootIDRemoteA | read-only | current | NID Series card STP Bridges status: MSTI9 - Root ID |
| 1.3.6.1.4.1.4756.20.501.20.1.1384 | ColumnnidMSTI9RootPortRemoteA | read-only | current | NID Series card STP Bridges status: MSTI9 - Root ID |
| 1.3.6.1.4.1.4756.20.501.20.1.1385 | ColumnnidMSTI9RootCostRemoteA | read-only | current | NID Series card STP Bridges status: MSTI9 - Root Cost |
| 1.3.6.1.4.1.4756.20.501.20.1.1386 | ColumnnidMSTI9TopologyFlagRemoteA | read-only | current | NID Series card STP Bridges status: MSTI9 - Topology Flag |
| 1.3.6.1.4.1.4756.20.501.20.1.1387 | ColumnnidMSTI9TopologyChangeLastRemoteA | read-only | current | NID Series card STP Bridges status: MSTI9 - Topology Change Last |
| 1.3.6.1.4.1.4756.20.501.20.1.1388 | ColumnnidMSTI10BridgeIDRemoteA | read-only | current | NID Series card STP Bridges status: MSTI10 - Bridge ID |
| 1.3.6.1.4.1.4756.20.501.20.1.1389 | ColumnnidMSTI10RootIDRemoteA | read-only | current | NID Series card STP Bridges status: MSTI10 - Root ID |
| 1.3.6.1.4.1.4756.20.501.20.1.1390 | ColumnnidMSTI10RootPortRemoteA | read-only | current | NID Series card STP Bridges status: MSTI10 - Root ID |
| 1.3.6.1.4.1.4756.20.501.20.1.1391 | ColumnnidMSTI10RootCostRemoteA | read-only | current | NID Series card STP Bridges status: MSTI10 - Root Cost |
| 1.3.6.1.4.1.4756.20.501.20.1.1392 | ColumnnidMSTI10TopologyFlagRemoteA | read-only | current | NID Series card STP Bridges status: MSTI10 - Topology Flag |
| 1.3.6.1.4.1.4756.20.501.20.1.1393 | ColumnnidMSTI10TopologyChangeLastRemoteA | read-only | current | NID Series card STP Bridges status: MSTI10 - Topology Change Last |
| 1.3.6.1.4.1.4756.20.501.20.1.1394 | ColumnnidMSTI11BridgeIDRemoteA | read-only | current | NID Series card STP Bridges status: MSTI11 - Bridge ID |
| 1.3.6.1.4.1.4756.20.501.20.1.1395 | ColumnnidMSTI11RootIDRemoteA | read-only | current | NID Series card STP Bridges status: MSTI11 - Root ID |
| 1.3.6.1.4.1.4756.20.501.20.1.1396 | ColumnnidMSTI11RootPortRemoteA | read-only | current | NID Series card STP Bridges status: MSTI11 - Root ID |
| 1.3.6.1.4.1.4756.20.501.20.1.1397 | ColumnnidMSTI11RootCostRemoteA | read-only | current | NID Series card STP Bridges status: MSTI11 - Root Cost |
| 1.3.6.1.4.1.4756.20.501.20.1.1398 | ColumnnidMSTI11TopologyFlagRemoteA | read-only | current | NID Series card STP Bridges status: MSTI11 - Topology Flag |
| 1.3.6.1.4.1.4756.20.501.20.1.1399 | ColumnnidMSTI11TopologyChangeLastRemoteA | read-only | current | NID Series card STP Bridges status: MSTI11 - Topology Change Last |
| 1.3.6.1.4.1.4756.20.501.20.1.1400 | ColumnnidMSTI12BridgeIDRemoteA | read-only | current | NID Series card STP Bridges status: MSTI12 - Bridge ID |
| 1.3.6.1.4.1.4756.20.501.20.1.1401 | ColumnnidMSTI12RootIDRemoteA | read-only | current | NID Series card STP Bridges status: MSTI12 - Root ID |
| 1.3.6.1.4.1.4756.20.501.20.1.1402 | ColumnnidMSTI12RootPortRemoteA | read-only | current | NID Series card STP Bridges status: MSTI12 - Root ID |
| 1.3.6.1.4.1.4756.20.501.20.1.1403 | ColumnnidMSTI12RootCostRemoteA | read-only | current | NID Series card STP Bridges status: MSTI12 - Root Cost |
| 1.3.6.1.4.1.4756.20.501.20.1.1404 | ColumnnidMSTI12TopologyFlagRemoteA | read-only | current | NID Series card STP Bridges status: MSTI12 - Topology Flag |
| 1.3.6.1.4.1.4756.20.501.20.1.1405 | ColumnnidMSTI12TopologyChangeLastRemoteA | read-only | current | NID Series card STP Bridges status: MSTI12 - Topology Change Last |
| 1.3.6.1.4.1.4756.20.501.20.1.1406 | ColumnnidMSTI13BridgeIDRemoteA | read-only | current | NID Series card STP Bridges status: MSTI13 - Bridge ID |
| 1.3.6.1.4.1.4756.20.501.20.1.1407 | ColumnnidMSTI13RootIDRemoteA | read-only | current | NID Series card STP Bridges status: MSTI13 - Root ID |
| 1.3.6.1.4.1.4756.20.501.20.1.1408 | ColumnnidMSTI13RootPortRemoteA | read-only | current | NID Series card STP Bridges status: MSTI13 - Root ID |
| 1.3.6.1.4.1.4756.20.501.20.1.1409 | ColumnnidMSTI13RootCostRemoteA | read-only | current | NID Series card STP Bridges status: MSTI13 - Root Cost |
| 1.3.6.1.4.1.4756.20.501.20.1.1410 | ColumnnidMSTI13TopologyFlagRemoteA | read-only | current | NID Series card STP Bridges status: MSTI13 - Topology Flag |
| 1.3.6.1.4.1.4756.20.501.20.1.1411 | ColumnnidMSTI13TopologyChangeLastRemoteA | read-only | current | NID Series card STP Bridges status: MSTI13 - Topology Change Last |
| 1.3.6.1.4.1.4756.20.501.20.1.1412 | ColumnnidMSTI14BridgeIDRemoteA | read-only | current | NID Series card STP Bridges status: MSTI14 - Bridge ID |
| 1.3.6.1.4.1.4756.20.501.20.1.1413 | ColumnnidMSTI14RootIDRemoteA | read-only | current | NID Series card STP Bridges status: MSTI14 - Root ID |
| 1.3.6.1.4.1.4756.20.501.20.1.1414 | ColumnnidMSTI14RootPortRemoteA | read-only | current | NID Series card STP Bridges status: MSTI14 - Root ID |
| 1.3.6.1.4.1.4756.20.501.20.1.1415 | ColumnnidMSTI14RootCostRemoteA | read-only | current | NID Series card STP Bridges status: MSTI14 - Root Cost |
| 1.3.6.1.4.1.4756.20.501.20.1.1416 | ColumnnidMSTI14TopologyFlagRemoteA | read-only | current | NID Series card STP Bridges status: MSTI14 - Topology Flag |
| 1.3.6.1.4.1.4756.20.501.20.1.1417 | ColumnnidMSTI14TopologyChangeLastRemoteA | read-only | current | NID Series card STP Bridges status: MSTI14 - Topology Change Last |
| 1.3.6.1.4.1.4756.20.501.20.1.1418 | ColumnnidMSTI15BridgeIDRemoteA | read-only | current | NID Series card STP Bridges status: MSTI15 - Bridge ID |
| 1.3.6.1.4.1.4756.20.501.20.1.1419 | ColumnnidMSTI15RootIDRemoteA | read-only | current | NID Series card STP Bridges status: MSTI15 - Root ID |
| 1.3.6.1.4.1.4756.20.501.20.1.1420 | ColumnnidMSTI15RootPortRemoteA | read-only | current | NID Series card STP Bridges status: MSTI15 - Root ID |
| 1.3.6.1.4.1.4756.20.501.20.1.1421 | ColumnnidMSTI15RootCostRemoteA | read-only | current | NID Series card STP Bridges status: MSTI15 - Root Cost |
| 1.3.6.1.4.1.4756.20.501.20.1.1422 | ColumnnidMSTI15TopologyFlagRemoteA | read-only | current | NID Series card STP Bridges status: MSTI15 - Topology Flag |
| 1.3.6.1.4.1.4756.20.501.20.1.1423 | ColumnnidMSTI15TopologyChangeLastRemoteA | read-only | current | NID Series card STP Bridges status: MSTI15 - Topology Change Last |
| 1.3.6.1.4.1.4756.20.501.20.1.1424 | ColumnnidSTPPortStatusInst1PortRemoteA | read-only | current | NID Series card STP Port status: Instance1 - Port |
| 1.3.6.1.4.1.4756.20.501.20.1.1425 | ColumnnidSTPPortStatusInst1CISTRoleRemoteA | read-only | current | NID Series card STP Port status: Instance1 - CIST Role |
| 1.3.6.1.4.1.4756.20.501.20.1.1426 | ColumnnidSTPPortStatusInst1CISTStateRemoteA | read-only | current | NID Series card STP Port status: Instance1 - CIST State |
| 1.3.6.1.4.1.4756.20.501.20.1.1427 | ColumnnidSTPPortStatusInst1UptimeRemoteA | read-only | current | NID Series card STP Port status: Instance1 -Uptime |
| 1.3.6.1.4.1.4756.20.501.20.1.1428 | ColumnnidSTPPortStatusInst2PortRemoteA | read-only | current | NID Series card STP Port status: Instance2 - Port |
| 1.3.6.1.4.1.4756.20.501.20.1.1429 | ColumnnidSTPPortStatusInst2CISTRoleRemoteA | read-only | current | NID Series card STP Port status: Instance2 - CIST Role |
| 1.3.6.1.4.1.4756.20.501.20.1.1430 | ColumnnidSTPPortStatusInst2CISTStateRemoteA | read-only | current | NID Series card STP Port status: Instance2 - CIST State |
| 1.3.6.1.4.1.4756.20.501.20.1.1431 | ColumnnidSTPPortStatusInst2UptimeRemoteA | read-only | current | NID Series card STP Port status: Instance2 -Uptime |
| 1.3.6.1.4.1.4756.20.501.20.1.1432 | ColumnnidSTPPortStatusInst3PortRemoteA | read-only | current | NID Series card STP Port status: Instance3 - Port |
| 1.3.6.1.4.1.4756.20.501.20.1.1433 | ColumnnidSTPPortStatusInst3CISTRoleRemoteA | read-only | current | NID Series card STP Port status: Instance3 - CIST Role |
| 1.3.6.1.4.1.4756.20.501.20.1.1434 | ColumnnidSTPPortStatusInst3CISTStateRemoteA | read-only | current | NID Series card STP Port status: Instance3 - CIST State |
| 1.3.6.1.4.1.4756.20.501.20.1.1435 | ColumnnidSTPPortStatusInst3UptimeRemoteA | read-only | current | NID Series card STP Port status: Instance3 -Uptime |
| 1.3.6.1.4.1.4756.20.501.20.1.1436 | ColumnnidSTPPortStatusInst4PortRemoteA | read-only | current | NID Series card STP Port status: Instance4 - Port |
| 1.3.6.1.4.1.4756.20.501.20.1.1437 | ColumnnidSTPPortStatusInst4CISTRoleRemoteA | read-only | current | NID Series card STP Port status: Instance4 - CIST Role |
| 1.3.6.1.4.1.4756.20.501.20.1.1438 | ColumnnidSTPPortStatusInst4CISTStateRemoteA | read-only | current | NID Series card STP Port status: Instance4 - CIST State |
| 1.3.6.1.4.1.4756.20.501.20.1.1439 | ColumnnidSTPPortStatusInst4UptimeRemoteA | read-only | current | NID Series card STP Port status: Instance4 -Uptime |
| 1.3.6.1.4.1.4756.20.501.20.1.1440 | ColumnnidSTPPortStatusInst5PortRemoteA | read-only | current | NID Series card STP Port status: Instance5 - Port |
| 1.3.6.1.4.1.4756.20.501.20.1.1441 | ColumnnidSTPPortStatusInst5CISTRoleRemoteA | read-only | current | NID Series card STP Port status: Instance5 - CIST Role |
| 1.3.6.1.4.1.4756.20.501.20.1.1442 | ColumnnidSTPPortStatusInst5CISTStateRemoteA | read-only | current | NID Series card STP Port status: Instance5 - CIST State |
| 1.3.6.1.4.1.4756.20.501.20.1.1443 | ColumnnidSTPPortStatusInst5UptimeRemoteA | read-only | current | NID Series card STP Port status: Instance5 -Uptime |
| 1.3.6.1.4.1.4756.20.501.20.1.1444 | ColumnnidSTPPortStatusInst6PortRemoteA | read-only | current | NID Series card STP Port status: Instance6- Port |
| 1.3.6.1.4.1.4756.20.501.20.1.1445 | ColumnnidSTPPortStatusInst6CISTRoleRemoteA | read-only | current | NID Series card STP Port status: Instance6- CIST Role |
| 1.3.6.1.4.1.4756.20.501.20.1.1446 | ColumnnidSTPPortStatusInst6CISTStateRemoteA | read-only | current | NID Series card STP Port status: Instance6- CIST State |
| 1.3.6.1.4.1.4756.20.501.20.1.1447 | ColumnnidSTPPortStatusInst6UptimeRemoteA | read-only | current | NID Series card STP Port status: Instance6-Uptime |
| 1.3.6.1.4.1.4756.20.501.20.1.1448 | ColumnnidSTPPortStatusInst7PortRemoteA | read-only | current | NID Series card STP Port status: Instance7- Port |
| 1.3.6.1.4.1.4756.20.501.20.1.1449 | ColumnnidSTPPortStatusInst7CISTRoleRemoteA | read-only | current | NID Series card STP Port status: Instance7- CIST Role |
| 1.3.6.1.4.1.4756.20.501.20.1.1450 | ColumnnidSTPPortStatusInst7CISTStateRemoteA | read-only | current | NID Series card STP Port status: Instance7- CIST State |
| 1.3.6.1.4.1.4756.20.501.20.1.1451 | ColumnnidSTPPortStatusInst7UptimeRemoteA | read-only | current | NID Series card STP Port status: Instance7-Uptime |
| 1.3.6.1.4.1.4756.20.501.20.1.1452 | ColumnnidSTPPortStatusInst8PortRemoteA | read-only | current | NID Series card STP Port status: Instance8- Port |
| 1.3.6.1.4.1.4756.20.501.20.1.1453 | ColumnnidSTPPortStatusInst8CISTRoleRemoteA | read-only | current | NID Series card STP Port status: Instance8- CIST Role |
| 1.3.6.1.4.1.4756.20.501.20.1.1454 | ColumnnidSTPPortStatusInst8CISTStateRemoteA | read-only | current | NID Series card STP Port status: Instance8- CIST State |
| 1.3.6.1.4.1.4756.20.501.20.1.1455 | ColumnnidSTPPortStatusInst8UptimeRemoteA | read-only | current | NID Series card STP Port status: Instance8-Uptime |
| 1.3.6.1.4.1.4756.20.501.20.1.1456 | ColumnnidSTPStatisticsPort1TxMSTPRemoteA | read-only | current | NID Series card STP Port Statistics: Port1 -Transmitted MSTP |
| 1.3.6.1.4.1.4756.20.501.20.1.1457 | ColumnnidSTPStatisticsPort1TxRSTPRemoteA | read-only | current | NID Series card STP Port Statistics: Port1 -Transmitted RSTP |
| 1.3.6.1.4.1.4756.20.501.20.1.1458 | ColumnnidSTPStatisticsPort1TxSTPRemoteA | read-only | current | NID Series card STP Port Statistics: Port1 -Transmitted RSTP |
| 1.3.6.1.4.1.4756.20.501.20.1.1459 | ColumnnidSTPStatisticsPort1TxTCNRemoteA | read-only | current | NID Series card STP Port Statistics: Port1 -Transmitted RSTP |
| 1.3.6.1.4.1.4756.20.501.20.1.1460 | ColumnnidSTPStatisticsPort1RxMSTPRemoteA | read-only | current | NID Series card STP Port Statistics: Port1 -Received MSTP |
| 1.3.6.1.4.1.4756.20.501.20.1.1461 | ColumnnidSTPStatisticsPort1RxRSTPRemoteA | read-only | current | NID Series card STP Port Statistics: Port1 -Received RSTP |
| 1.3.6.1.4.1.4756.20.501.20.1.1462 | ColumnnidSTPStatisticsPort1RxSTPRemoteA | read-only | current | NID Series card STP Port Statistics: Port1 -Received RSTP |
| 1.3.6.1.4.1.4756.20.501.20.1.1463 | ColumnnidSTPStatisticsPort1RxTCNRemoteA | read-only | current | NID Series card STP Port Statistics: Port1 -Received RSTP |
| 1.3.6.1.4.1.4756.20.501.20.1.1464 | ColumnnidSTPStatisticsPort1DiscardUnknowRemoteA | read-only | current | NID Series card STP Port Statistics: Port1 -Discarded Unknown |
| 1.3.6.1.4.1.4756.20.501.20.1.1465 | ColumnnidSTPStatisticsPort1DiscardIllegalRemoteA | read-only | current | NID Series card STP Port Statistics: Port1 -Discarded Illegal |
| 1.3.6.1.4.1.4756.20.501.20.1.1466 | ColumnnidSTPStatisticsPort2TxMSTPRemoteA | read-only | current | NID Series card STP Port Statistics: Port2 -Transmitted MSTP |
| 1.3.6.1.4.1.4756.20.501.20.1.1467 | ColumnnidSTPStatisticsPort2TxRSTPRemoteA | read-only | current | NID Series card STP Port Statistics: Port2 -Transmitted RSTP |
| 1.3.6.1.4.1.4756.20.501.20.1.1468 | ColumnnidSTPStatisticsPort2TxSTPRemoteA | read-only | current | NID Series card STP Port Statistics: Port2 -Transmitted RSTP |
| 1.3.6.1.4.1.4756.20.501.20.1.1469 | ColumnnidSTPStatisticsPort2TxTCNRemoteA | read-only | current | NID Series card STP Port Statistics: Port2 -Transmitted RSTP |
| 1.3.6.1.4.1.4756.20.501.20.1.1470 | ColumnnidSTPStatisticsPort2RxMSTPRemoteA | read-only | current | NID Series card STP Port Statistics: Port2 -Received MSTP |
| 1.3.6.1.4.1.4756.20.501.20.1.1471 | ColumnnidSTPStatisticsPort2RxRSTPRemoteA | read-only | current | NID Series card STP Port Statistics: Port1 -Received RSTP |
| 1.3.6.1.4.1.4756.20.501.20.1.1472 | ColumnnidSTPStatisticsPort2RxSTPRemoteA | read-only | current | NID Series card STP Port Statistics: Port2 -Received RSTP |
| 1.3.6.1.4.1.4756.20.501.20.1.1473 | ColumnnidSTPStatisticsPort2RxTCNRemoteA | read-only | current | NID Series card STP Port Statistics: Port2 -Received RSTP |
| 1.3.6.1.4.1.4756.20.501.20.1.1474 | ColumnnidSTPStatisticsPort2DiscardUnknowRemoteA | read-only | current | NID Series card STP Port Statistics: Port2 -Discarded Unknown |
| 1.3.6.1.4.1.4756.20.501.20.1.1475 | ColumnnidSTPStatisticsPort2DiscardIllegalRemoteA | read-only | current | NID Series card STP Port Statistics: Port2 -Discarded Illegal |
| 1.3.6.1.4.1.4756.20.501.20.1.1476 | ColumnnidSTPStatisticsPort3TxMSTPRemoteA | read-only | current | NID Series card STP Port Statistics: Port3 -Transmitted MSTP |
| 1.3.6.1.4.1.4756.20.501.20.1.1477 | ColumnnidSTPStatisticsPort3TxRSTPRemoteA | read-only | current | NID Series card STP Port Statistics: Port3 -Transmitted RSTP |
| 1.3.6.1.4.1.4756.20.501.20.1.1478 | ColumnnidSTPStatisticsPort3TxSTPRemoteA | read-only | current | NID Series card STP Port Statistics: Port3 -Transmitted RSTP |
| 1.3.6.1.4.1.4756.20.501.20.1.1479 | ColumnnidSTPStatisticsPort3TxTCNRemoteA | read-only | current | NID Series card STP Port Statistics: Port3 -Transmitted RSTP |
| 1.3.6.1.4.1.4756.20.501.20.1.1480 | ColumnnidSTPStatisticsPort3RxMSTPRemoteA | read-only | current | NID Series card STP Port Statistics: Port3 -Received MSTP |
| 1.3.6.1.4.1.4756.20.501.20.1.1481 | ColumnnidSTPStatisticsPort3RxRSTPRemoteA | read-only | current | NID Series card STP Port Statistics: Port3 -Received RSTP |
| 1.3.6.1.4.1.4756.20.501.20.1.1482 | ColumnnidSTPStatisticsPort3RxSTPRemoteA | read-only | current | NID Series card STP Port Statistics: Port3 -Received RSTP |
| 1.3.6.1.4.1.4756.20.501.20.1.1483 | ColumnnidSTPStatisticsPort3RxTCNRemoteA | read-only | current | NID Series card STP Port Statistics: Port3 -Received RSTP |
| 1.3.6.1.4.1.4756.20.501.20.1.1484 | ColumnnidSTPStatisticsPort3DiscardUnknowRemoteA | read-only | current | NID Series card STP Port Statistics: Port3 -Discarded Unknown |
| 1.3.6.1.4.1.4756.20.501.20.1.1485 | ColumnnidSTPStatisticsPort3DiscardIllegalRemoteA | read-only | current | NID Series card STP Port Statistics: Port3 -Discarded Illegal |
| 1.3.6.1.4.1.4756.20.501.20.1.1486 | ColumnnidSTPStatisticsPort4TxMSTPRemoteA | read-only | current | NID Series card STP Port Statistics: Port4 -Transmitted MSTP |
| 1.3.6.1.4.1.4756.20.501.20.1.1487 | ColumnnidSTPStatisticsPort4TxRSTPRemoteA | read-only | current | NID Series card STP Port Statistics: Port4 -Transmitted RSTP |
| 1.3.6.1.4.1.4756.20.501.20.1.1488 | ColumnnidSTPStatisticsPort4TxSTPRemoteA | read-only | current | NID Series card STP Port Statistics: Port4 -Transmitted RSTP |
| 1.3.6.1.4.1.4756.20.501.20.1.1489 | ColumnnidSTPStatisticsPort4TxTCNRemoteA | read-only | current | NID Series card STP Port Statistics: Port4 -Transmitted RSTP |
| 1.3.6.1.4.1.4756.20.501.20.1.1490 | ColumnnidSTPStatisticsPort4RxMSTPRemoteA | read-only | current | NID Series card STP Port Statistics: Port4 -Received MSTP |
| 1.3.6.1.4.1.4756.20.501.20.1.1491 | ColumnnidSTPStatisticsPort4RxRSTPRemoteA | read-only | current | NID Series card STP Port Statistics: Port4 -Received RSTP |
| 1.3.6.1.4.1.4756.20.501.20.1.1492 | ColumnnidSTPStatisticsPort4RxSTPRemoteA | read-only | current | NID Series card STP Port Statistics: Port4 -Received RSTP |
| 1.3.6.1.4.1.4756.20.501.20.1.1493 | ColumnnidSTPStatisticsPort4RxTCNRemoteA | read-only | current | NID Series card STP Port Statistics: Port4 -Received RSTP |
| 1.3.6.1.4.1.4756.20.501.20.1.1494 | ColumnnidSTPStatisticsPort4DiscardUnknowRemoteA | read-only | current | NID Series card STP Port Statistics: Port4 -Discarded Unknown |
| 1.3.6.1.4.1.4756.20.501.20.1.1495 | ColumnnidSTPStatisticsPort4DiscardIllegalRemoteA | read-only | current | NID Series card STP Port Statistics: Port4 -Discarded Illegal |
| 1.3.6.1.4.1.4756.20.501.20.1.1496 | ColumnnidSTPStatisticsPort5TxMSTPRemoteA | read-only | current | NID Series card STP Port Statistics: Port5 -Transmitted MSTP |
| 1.3.6.1.4.1.4756.20.501.20.1.1497 | ColumnnidSTPStatisticsPort5TxRSTPRemoteA | read-only | current | NID Series card STP Port Statistics: Port5 -Transmitted RSTP |
| 1.3.6.1.4.1.4756.20.501.20.1.1498 | ColumnnidSTPStatisticsPort5TxSTPRemoteA | read-only | current | NID Series card STP Port Statistics: Port5 -Transmitted RSTP |
| 1.3.6.1.4.1.4756.20.501.20.1.1499 | ColumnnidSTPStatisticsPort5TxTCNRemoteA | read-only | current | NID Series card STP Port Statistics: Port5 -Transmitted RSTP |
| 1.3.6.1.4.1.4756.20.501.20.1.1500 | ColumnnidSTPStatisticsPort5RxMSTPRemoteA | read-only | current | NID Series card STP Port Statistics: Port5 -Received MSTP |
| 1.3.6.1.4.1.4756.20.501.20.1.1501 | ColumnnidSTPStatisticsPort5RxRSTPRemoteA | read-only | current | NID Series card STP Port Statistics: Port5 -Received RSTP |
| 1.3.6.1.4.1.4756.20.501.20.1.1502 | ColumnnidSTPStatisticsPort5RxSTPRemoteA | read-only | current | NID Series card STP Port Statistics: Port5 -Received RSTP |
| 1.3.6.1.4.1.4756.20.501.20.1.1503 | ColumnnidSTPStatisticsPort5RxTCNRemoteA | read-only | current | NID Series card STP Port Statistics: Port5 -Received RSTP |
| 1.3.6.1.4.1.4756.20.501.20.1.1504 | ColumnnidSTPStatisticsPort5DiscardUnknowRemoteA | read-only | current | NID Series card STP Port Statistics: Port5 -Discarded Unknown |
| 1.3.6.1.4.1.4756.20.501.20.1.1505 | ColumnnidSTPStatisticsPort5DiscardIllegalRemoteA | read-only | current | NID Series card STP Port Statistics: Port5 -Discarded Illegal |
| 1.3.6.1.4.1.4756.20.501.20.1.1506 | ColumnnidSTPStatisticsPort6TxMSTPRemoteA | read-only | current | NID Series card STP Port Statistics: Port6 -Transmitted MSTP |
| 1.3.6.1.4.1.4756.20.501.20.1.1507 | ColumnnidSTPStatisticsPort6TxRSTPRemoteA | read-only | current | NID Series card STP Port Statistics: Port6 -Transmitted RSTP |
| 1.3.6.1.4.1.4756.20.501.20.1.1508 | ColumnnidSTPStatisticsPort6TxSTPRemoteA | read-only | current | NID Series card STP Port Statistics: Port6 -Transmitted RSTP |
| 1.3.6.1.4.1.4756.20.501.20.1.1509 | ColumnnidSTPStatisticsPort6TxTCNRemoteA | read-only | current | NID Series card STP Port Statistics: Port6 -Transmitted RSTP |
| 1.3.6.1.4.1.4756.20.501.20.1.1510 | ColumnnidSTPStatisticsPort6RxMSTPRemoteA | read-only | current | NID Series card STP Port Statistics: Port6 -Received MSTP |
| 1.3.6.1.4.1.4756.20.501.20.1.1511 | ColumnnidSTPStatisticsPort6RxRSTPRemoteA | read-only | current | NID Series card STP Port Statistics: Port6 -Received RSTP |
| 1.3.6.1.4.1.4756.20.501.20.1.1512 | ColumnnidSTPStatisticsPort6RxSTPRemoteA | read-only | current | NID Series card STP Port Statistics: Port6 -Received RSTP |
| 1.3.6.1.4.1.4756.20.501.20.1.1513 | ColumnnidSTPStatisticsPort6RxTCNRemoteA | read-only | current | NID Series card STP Port Statistics: Port6 -Received RSTP |
| 1.3.6.1.4.1.4756.20.501.20.1.1514 | ColumnnidSTPStatisticsPort6DiscardUnknowRemoteA | read-only | current | NID Series card STP Port Statistics: Port6 -Discarded Unknown |
| 1.3.6.1.4.1.4756.20.501.20.1.1515 | ColumnnidSTPStatisticsPort6DiscardIllegalRemoteA | read-only | current | NID Series card STP Port Statistics: Port6 -Discarded Illegal |
| 1.3.6.1.4.1.4756.20.501.20.1.1516 | ColumnnidSTPStatisticsPort7TxMSTPRemoteA | read-only | current | NID Series card STP Port Statistics: Port7 -Transmitted MSTP |
| 1.3.6.1.4.1.4756.20.501.20.1.1517 | ColumnnidSTPStatisticsPort7TxRSTPRemoteA | read-only | current | NID Series card STP Port Statistics: Port7 -Transmitted RSTP |
| 1.3.6.1.4.1.4756.20.501.20.1.1518 | ColumnnidSTPStatisticsPort7TxSTPRemoteA | read-only | current | NID Series card STP Port Statistics: Port7 -Transmitted RSTP |
| 1.3.6.1.4.1.4756.20.501.20.1.1519 | ColumnnidSTPStatisticsPort7TxTCNRemoteA | read-only | current | NID Series card STP Port Statistics: Port7 -Transmitted RSTP |
| 1.3.6.1.4.1.4756.20.501.20.1.1520 | ColumnnidSTPStatisticsPort7RxMSTPRemoteA | read-only | current | NID Series card STP Port Statistics: Port7 -Received MSTP |
| 1.3.6.1.4.1.4756.20.501.20.1.1521 | ColumnnidSTPStatisticsPort7RxRSTPRemoteA | read-only | current | NID Series card STP Port Statistics: Port7 -Received RSTP |
| 1.3.6.1.4.1.4756.20.501.20.1.1522 | ColumnnidSTPStatisticsPort7RxSTPRemoteA | read-only | current | NID Series card STP Port Statistics: Port7 -Received RSTP |
| 1.3.6.1.4.1.4756.20.501.20.1.1523 | ColumnnidSTPStatisticsPort7RxTCNRemoteA | read-only | current | NID Series card STP Port Statistics: Port7 -Received RSTP |
| 1.3.6.1.4.1.4756.20.501.20.1.1524 | ColumnnidSTPStatisticsPort7DiscardUnknowRemoteA | read-only | current | NID Series card STP Port Statistics: Port7 -Discarded Unknown |
| 1.3.6.1.4.1.4756.20.501.20.1.1525 | ColumnnidSTPStatisticsPort7DiscardIllegalRemoteA | read-only | current | NID Series card STP Port Statistics: Port7 -Discarded Illegal |
| 1.3.6.1.4.1.4756.20.501.20.1.1526 | ColumnnidSTPStatisticsPort8TxMSTPRemoteA | read-only | current | NID Series card STP Port Statistics: Port8 -Transmitted MSTP |
| 1.3.6.1.4.1.4756.20.501.20.1.1527 | ColumnnidSTPStatisticsPort8TxRSTPRemoteA | read-only | current | NID Series card STP Port Statistics: Port8 -Transmitted RSTP |
| 1.3.6.1.4.1.4756.20.501.20.1.1528 | ColumnnidSTPStatisticsPort8TxSTPRemoteA | read-only | current | NID Series card STP Port Statistics: Port8 -Transmitted RSTP |
| 1.3.6.1.4.1.4756.20.501.20.1.1529 | ColumnnidSTPStatisticsPort8TxTCNRemoteA | read-only | current | NID Series card STP Port Statistics: Port8 -Transmitted RSTP |
| 1.3.6.1.4.1.4756.20.501.20.1.1530 | ColumnnidSTPStatisticsPort8RxMSTPRemoteA | read-only | current | NID Series card STP Port Statistics: Port8 -Received MSTP |
| 1.3.6.1.4.1.4756.20.501.20.1.1531 | ColumnnidSTPStatisticsPort8RxRSTPRemoteA | read-only | current | NID Series card STP Port Statistics: Port8 -Received RSTP |
| 1.3.6.1.4.1.4756.20.501.20.1.1532 | ColumnnidSTPStatisticsPort8RxSTPRemoteA | read-only | current | NID Series card STP Port Statistics: Port8 -Received RSTP |
| 1.3.6.1.4.1.4756.20.501.20.1.1533 | ColumnnidSTPStatisticsPort8RxTCNRemoteA | read-only | current | NID Series card STP Port Statistics: Port8 -Received RSTP |
| 1.3.6.1.4.1.4756.20.501.20.1.1534 | ColumnnidSTPStatisticsPort8DiscardUnknowRemoteA | read-only | current | NID Series card STP Port Statistics: Port8 -Discarded Unknown |
| 1.3.6.1.4.1.4756.20.501.20.1.1535 | ColumnnidSTPStatisticsPort8DiscardIllegalRemoteA | read-only | current | NID Series card STP Port Statistics: Port8 -Discarded Illegal |
| 1.3.6.1.4.1.4756.20.501.20.1.1536 | ColumnnidAllowedAccessVLANsRemoteA | read-write | current | NID Series card Global VLAN Configuration: Allowed Access VLANs By default, only VLAN 1 is enabled. More VLANs may be created by using a list syntax where the … |
| 1.3.6.1.4.1.4756.20.501.20.1.1537 | ColumnnidVlanEthertypeRemoteA | read-write | current | NID Series card Global VLAN Configuration: Ethertype for Custom S-ports The format of 'Ethernet Type' is restricted to 0x600-0xFFFF |
| 1.3.6.1.4.1.4756.20.501.20.1.1538 | ColumnnidPort1VlanModeRemoteA | read-write | current | NID Series card Port VLAN Configuration : Port1 - Mode 0: Access 1: Trunk 2: Hybrid |
| 1.3.6.1.4.1.4756.20.501.20.1.1539 | ColumnnidPort1VlanIDRemoteA | read-write | current | NID Series card Port VLAN Configuration : Port1 - VLAN ID |
| 1.3.6.1.4.1.4756.20.501.20.1.1540 | ColumnnidPort1VlanTypeRemoteA | read-write | current | NID Series card Port VLAN Configuration : Port1 - VLAN Type 0: Unaware 1: C-port 2: S-port 3: S-custom-port |
| 1.3.6.1.4.1.4756.20.501.20.1.1541 | ColumnnidPort1VlanIngressFilteringRemoteA | read-write | current | NID Series card Port VLAN Configuration : Port1 - Ingress Filtering 0: Off 1: On |
| 1.3.6.1.4.1.4756.20.501.20.1.1542 | ColumnnidPort1VlanIngressAcceptanceRemoteA | read-write | current | NID Series card Port VLAN Configuration : Port1 - Ingress Acceptance 0: Tagged and untagged 1: Tagged only 2: Untagged only |
| 1.3.6.1.4.1.4756.20.501.20.1.1543 | ColumnnidPort1VlanEgressTaggingRemoteA | read-write | current | NID Series card Port VLAN Configuration : Port1 - Egress Tagging 0: Untag port vlan 1: Tag all 2: Untag all |
| 1.3.6.1.4.1.4756.20.501.20.1.1544 | ColumnnidPort1AllowedVLANSRemoteA | read-write | current | NID Series card Global VLAN Configuration: Port1 - Allowed VLANs By default, only VLAN 1 is enabled. More VLANs may be created by using a list syntax where the… |
| 1.3.6.1.4.1.4756.20.501.20.1.1545 | ColumnnidPort1ForbiddenVLANSRemoteA | read-write | current | NID Series card Global VLAN Configuration: Port1 - Forbidden VLANs By default, the field is left blank, which means that the port may become a member of all po… |
| 1.3.6.1.4.1.4756.20.501.20.1.1546 | ColumnnidPort2VlanModeRemoteA | read-write | current | NID Series card Port VLAN Configuration : Port2 - Mode 0: Access 1: Trunk 2: Hybrid |
| 1.3.6.1.4.1.4756.20.501.20.1.1547 | ColumnnidPort2VlanIDRemoteA | read-write | current | NID Series card Port VLAN Configuration : Port2 - VLAN ID |
| 1.3.6.1.4.1.4756.20.501.20.1.1548 | ColumnnidPort2VlanTypeRemoteA | read-write | current | NID Series card Port VLAN Configuration : Port2 - VLAN Type 0: Unaware 1: C-port 2: S-port 3: S-custom-port |
| 1.3.6.1.4.1.4756.20.501.20.1.1549 | ColumnnidPort2VlanIngressFilteringRemoteA | read-write | current | NID Series card Port VLAN Configuration : Port2 - Ingress Filtering 0: Off 1: On |
| 1.3.6.1.4.1.4756.20.501.20.1.1550 | ColumnnidPort2VlanIngressAcceptanceRemoteA | read-write | current | NID Series card Port VLAN Configuration : Por2 - Ingress Acceptance 0: Tagged and untagged 1: Tagged only 2: Untagged only |
| 1.3.6.1.4.1.4756.20.501.20.1.1551 | ColumnnidPort2VlanEgressTaggingRemoteA | read-write | current | NID Series card Port VLAN Configuration : Port2 - Egress Tagging 0: Untag port vlan 1: Tag all 2: Untag all |
| 1.3.6.1.4.1.4756.20.501.20.1.1552 | ColumnnidPort2AllowedVLANSRemoteA | read-write | current | NID Series card Global VLAN Configuration: Port2 - Allowed VLANs By default, only VLAN 1 is enabled. More VLANs may be created by using a list syntax where the… |
| 1.3.6.1.4.1.4756.20.501.20.1.1553 | ColumnnidPort2ForbiddenVLANSRemoteA | read-write | current | NID Series card Global VLAN Configuration: Port2 - Forbidden VLANs By default, the field is left blank, which means that the port may become a member of all po… |
| 1.3.6.1.4.1.4756.20.501.20.1.1554 | ColumnnidPort3VlanModeRemoteA | read-write | current | NID Series card Port VLAN Configuration : Port3 - Mode 0: Access 1: Trunk 2: Hybrid |
| 1.3.6.1.4.1.4756.20.501.20.1.1555 | ColumnnidPort3VlanIDRemoteA | read-write | current | NID Series card Port VLAN Configuration : Port3 - VLAN ID |
| 1.3.6.1.4.1.4756.20.501.20.1.1556 | ColumnnidPort3VlanTypeRemoteA | read-write | current | NID Series card Port VLAN Configuration : Port3 - VLAN Type 0: Unaware 1: C-port 2: S-port 3: S-custom-port |
| 1.3.6.1.4.1.4756.20.501.20.1.1557 | ColumnnidPort3VlanIngressFilteringRemoteA | read-write | current | NID Series card Port VLAN Configuration : Port3 - Ingress Filtering 0: Off 1: On |
| 1.3.6.1.4.1.4756.20.501.20.1.1558 | ColumnnidPort3VlanIngressAcceptanceRemoteA | read-write | current | NID Series card Port VLAN Configuration : Port3 - Ingress Acceptance 0: Tagged and untagged 1: Tagged only 2: Untagged only |
| 1.3.6.1.4.1.4756.20.501.20.1.1559 | ColumnnidPort3VlanEgressTaggingRemoteA | read-write | current | NID Series card Port VLAN Configuration : Port3 - Egress Tagging 0: Untag port vlan 1: Tag all 2: Untag all |
| 1.3.6.1.4.1.4756.20.501.20.1.1560 | ColumnnidPort3AllowedVLANSRemoteA | read-write | current | NID Series card Global VLAN Configuration: Port3 - Allowed VLANs By default, only VLAN 1 is enabled. More VLANs may be created by using a list syntax where the… |
| 1.3.6.1.4.1.4756.20.501.20.1.1561 | ColumnnidPort3ForbiddenVLANSRemoteA | read-write | current | NID Series card Global VLAN Configuration: Port3 - Forbidden VLANs By default, the field is left blank, which means that the port may become a member of all po… |
| 1.3.6.1.4.1.4756.20.501.20.1.1562 | ColumnnidPort4VlanModeRemoteA | read-write | current | NID Series card Port VLAN Configuration : Port4 - Mode 0: Access 1: Trunk 2: Hybrid |
| 1.3.6.1.4.1.4756.20.501.20.1.1563 | ColumnnidPort4VlanIDRemoteA | read-write | current | NID Series card Port VLAN Configuration : Port4 - VLAN ID |
| 1.3.6.1.4.1.4756.20.501.20.1.1564 | ColumnnidPort4VlanTypeRemoteA | read-write | current | NID Series card Port VLAN Configuration : Port4 - VLAN Type 0: Unaware 1: C-port 2: S-port 3: S-custom-port |
| 1.3.6.1.4.1.4756.20.501.20.1.1565 | ColumnnidPort4VlanIngressFilteringRemoteA | read-write | current | NID Series card Port VLAN Configuration : Port4 - Ingress Filtering 0: Off 1: On |
| 1.3.6.1.4.1.4756.20.501.20.1.1566 | ColumnnidPort4VlanIngressAcceptanceRemoteA | read-write | current | NID Series card Port VLAN Configuration : Port4 - Ingress Acceptance 0: Tagged and untagged 1: Tagged only 2: Untagged only |
| 1.3.6.1.4.1.4756.20.501.20.1.1567 | ColumnnidPort4VlanEgressTaggingRemoteA | read-write | current | NID Series card Port VLAN Configuration : Port4 - Egress Tagging 0: Untag port vlan 1: Tag all 2: Untag all |
| 1.3.6.1.4.1.4756.20.501.20.1.1568 | ColumnnidPort4AllowedVLANSRemoteA | read-write | current | NID Series card Global VLAN Configuration: Port4 - Allowed VLANs By default, only VLAN 1 is enabled. More VLANs may be created by using a list syntax where the… |
| 1.3.6.1.4.1.4756.20.501.20.1.1569 | ColumnnidPort4ForbiddenVLANSRemoteA | read-write | current | NID Series card Global VLAN Configuration: Port4 - Forbidden VLANs By default, the field is left blank, which means that the port may become a member of all po… |
| 1.3.6.1.4.1.4756.20.501.20.1.1570 | ColumnnidPort5VlanModeRemoteA | read-write | current | NID Series card Port VLAN Configuration : Port5 - Mode 0: Access 1: Trunk 2: Hybrid |
| 1.3.6.1.4.1.4756.20.501.20.1.1571 | ColumnnidPort5VlanIDRemoteA | read-write | current | NID Series card Port VLAN Configuration : Port5 - VLAN ID |
| 1.3.6.1.4.1.4756.20.501.20.1.1572 | ColumnnidPort5VlanTypeRemoteA | read-write | current | NID Series card Port VLAN Configuration : Port5 - VLAN Type 0: Unaware 1: C-port 2: S-port 3: S-custom-port |
| 1.3.6.1.4.1.4756.20.501.20.1.1573 | ColumnnidPort5VlanIngressFilteringRemoteA | read-write | current | NID Series card Port VLAN Configuration : Port5 - Ingress Filtering 0: Off 1: On |
| 1.3.6.1.4.1.4756.20.501.20.1.1574 | ColumnnidPort5VlanIngressAcceptanceRemoteA | read-write | current | NID Series card Port VLAN Configuration : Port5 - Ingress Acceptance 0: Tagged and untagged 1: Tagged only 2: Untagged only |
| 1.3.6.1.4.1.4756.20.501.20.1.1575 | ColumnnidPort5VlanEgressTaggingRemoteA | read-write | current | NID Series card Port VLAN Configuration : Port5 - Egress Tagging 0: Untag port vlan 1: Tag all 2: Untag all |
| 1.3.6.1.4.1.4756.20.501.20.1.1576 | ColumnnidPort5AllowedVLANSRemoteA | read-write | current | NID Series card Global VLAN Configuration: Port5 - Allowed VLANs By default, only VLAN 1 is enabled. More VLANs may be created by using a list syntax where the… |
| 1.3.6.1.4.1.4756.20.501.20.1.1577 | ColumnnidPort5ForbiddenVLANSRemoteA | read-write | current | NID Series card Global VLAN Configuration: Port5 - Forbidden VLANs By default, the field is left blank, which means that the port may become a member of all po… |
| 1.3.6.1.4.1.4756.20.501.20.1.1578 | ColumnnidPort6VlanModeRemoteA | read-write | current | NID Series card Port VLAN Configuration : Port6 - Mode 0: Access 1: Trunk 2: Hybrid |
| 1.3.6.1.4.1.4756.20.501.20.1.1579 | ColumnnidPort6VlanIDRemoteA | read-write | current | NID Series card Port VLAN Configuration : Port6 - VLAN ID |
| 1.3.6.1.4.1.4756.20.501.20.1.1580 | ColumnnidPort6VlanTypeRemoteA | read-write | current | NID Series card Port VLAN Configuration : Port6 - VLAN Type 0: Unaware 1: C-port 2: S-port 3: S-custom-port |
| 1.3.6.1.4.1.4756.20.501.20.1.1581 | ColumnnidPort6VlanIngressFilteringRemoteA | read-write | current | NID Series card Port VLAN Configuration : Port6 - Ingress Filtering 0: Off 1: On |
| 1.3.6.1.4.1.4756.20.501.20.1.1582 | ColumnnidPort6VlanIngressAcceptanceRemoteA | read-write | current | NID Series card Port VLAN Configuration : Port6 - Ingress Acceptance 0: Tagged and untagged 1: Tagged only 2: Untagged only |
| 1.3.6.1.4.1.4756.20.501.20.1.1583 | ColumnnidPort6VlanEgressTaggingRemoteA | read-write | current | NID Series card Port VLAN Configuration : Port6 - Egress Tagging 0: Untag port vlan 1: Tag all 2: Untag all |
| 1.3.6.1.4.1.4756.20.501.20.1.1584 | ColumnnidPort6AllowedVLANSRemoteA | read-write | current | NID Series card Global VLAN Configuration: Port6 - Allowed VLANs By default, only VLAN 1 is enabled. More VLANs may be created by using a list syntax where the… |
| 1.3.6.1.4.1.4756.20.501.20.1.1585 | ColumnnidPort6ForbiddenVLANSRemoteA | read-write | current | NID Series card Global VLAN Configuration: Port6 - Forbidden VLANs By default, the field is left blank, which means that the port may become a member of all po… |
| 1.3.6.1.4.1.4756.20.501.20.1.1586 | ColumnnidPort7VlanModeRemoteA | read-write | current | NID Series card Port VLAN Configuration : Port7 - Mode 0: Access 1: Trunk 2: Hybrid |
| 1.3.6.1.4.1.4756.20.501.20.1.1587 | ColumnnidPort7VlanIDRemoteA | read-write | current | NID Series card Port VLAN Configuration : Port7 - VLAN ID |
| 1.3.6.1.4.1.4756.20.501.20.1.1588 | ColumnnidPort7VlanTypeRemoteA | read-write | current | NID Series card Port VLAN Configuration : Port7 - VLAN Type 0: Unaware 1: C-port 2: S-port 3: S-custom-port |
| 1.3.6.1.4.1.4756.20.501.20.1.1589 | ColumnnidPort7VlanIngressFilteringRemoteA | read-write | current | NID Series card Port VLAN Configuration : Port7 - Ingress Filtering 0: Off 1: On |
| 1.3.6.1.4.1.4756.20.501.20.1.1590 | ColumnnidPort7VlanIngressAcceptanceRemoteA | read-write | current | NID Series card Port VLAN Configuration : Port7 - Ingress Acceptance 0: Tagged and untagged 1: Tagged only 2: Untagged only |
| 1.3.6.1.4.1.4756.20.501.20.1.1591 | ColumnnidPort7VlanEgressTaggingRemoteA | read-write | current | NID Series card Port VLAN Configuration : Port7 - Egress Tagging 0: Untag port vlan 1: Tag all 2: Untag all |
| 1.3.6.1.4.1.4756.20.501.20.1.1592 | ColumnnidPort7AllowedVLANSRemoteA | read-write | current | NID Series card Global VLAN Configuration: Port7 - Allowed VLANs By default, only VLAN 1 is enabled. More VLANs may be created by using a list syntax where the… |
| 1.3.6.1.4.1.4756.20.501.20.1.1593 | ColumnnidPort7ForbiddenVLANSRemoteA | read-write | current | NID Series card Global VLAN Configuration: Port7 - Forbidden VLANs By default, the field is left blank, which means that the port may become a member of all po… |
| 1.3.6.1.4.1.4756.20.501.20.1.1594 | ColumnnidPort8VlanModeRemoteA | read-write | current | NID Series card Port VLAN Configuration : Port8 - Mode 0: Access 1: Trunk 2: Hybrid |
| 1.3.6.1.4.1.4756.20.501.20.1.1595 | ColumnnidPort8VlanIDRemoteA | read-write | current | NID Series card Port VLAN Configuration : Port8 - VLAN ID |
| 1.3.6.1.4.1.4756.20.501.20.1.1596 | ColumnnidPort8VlanTypeRemoteA | read-write | current | NID Series card Port VLAN Configuration : Port8 - VLAN Type 0: Unaware 1: C-port 2: S-port 3: S-custom-port |
| 1.3.6.1.4.1.4756.20.501.20.1.1597 | ColumnnidPort8VlanIngressFilteringRemoteA | read-write | current | NID Series card Port VLAN Configuration : Port8 - Ingress Filtering 0: Off 1: On |
| 1.3.6.1.4.1.4756.20.501.20.1.1598 | ColumnnidPort8VlanIngressAcceptanceRemoteA | read-write | current | NID Series card Port VLAN Configuration : Port8 - Ingress Acceptance 0: Tagged and untagged 1: Tagged only 2: Untagged only |
| 1.3.6.1.4.1.4756.20.501.20.1.1599 | ColumnnidPort8VlanEgressTaggingRemoteA | read-write | current | NID Series card Port VLAN Configuration : Port8 - Egress Tagging 0: Untag port vlan 1: Tag all 2: Untag all |
| 1.3.6.1.4.1.4756.20.501.20.1.1600 | ColumnnidPort8AllowedVLANSRemoteA | read-write | current | NID Series card Global VLAN Configuration: Port8 - Allowed VLANs By default, only VLAN 1 is enabled. More VLANs may be created by using a list syntax where the… |
| 1.3.6.1.4.1.4756.20.501.20.1.1601 | ColumnnidPort8ForbiddenVLANSRemoteA | read-write | current | NID Series card Global VLAN Configuration: Port8 - Forbidden VLANs By default, the field is left blank, which means that the port may become a member of all po… |
| 1.3.6.1.4.1.4756.20.501.20.1.1602 | ColumnnidQOSPort1IngressRemoteA | read-write | current | NID Series card QOS Port1 Ingress Enabled 0: NO 1: YES |
| 1.3.6.1.4.1.4756.20.501.20.1.1603 | ColumnnidQOSPort1IngressRateRemoteA | read-write | current | NID Series card QOS Port1 Ingress Rate |
| 1.3.6.1.4.1.4756.20.501.20.1.1604 | ColumnnidQOSPort1IngressRateUnitRemoteA | read-write | current | NID Series card QOS Port1 Ingress Rate Unit 0: Kbps 1: Mbps 2: fps 3: kfps |
| 1.3.6.1.4.1.4756.20.501.20.1.1605 | ColumnnidQOSPort1IngressFlowControlRemoteA | read-write | current | NID Series card QOS Port1 Ingress Flow Control 0: NO 1: YES |
| 1.3.6.1.4.1.4756.20.501.20.1.1606 | ColumnnidQOSPort2IngressRemoteA | read-write | current | NID Series card QOS Port2 Ingress Enabled 0: NO 1: YES |
| 1.3.6.1.4.1.4756.20.501.20.1.1607 | ColumnnidQOSPort2IngressRateRemoteA | read-write | current | NID Series card QOS Port2 Ingress Rate |
| 1.3.6.1.4.1.4756.20.501.20.1.1608 | ColumnnidQOSPort2IngressRateUnitRemoteA | read-write | current | NID Series card QOS Port2 Ingress Rate Unit 0: Kbps 1: Mbps 2: fps 3: kfps |
| 1.3.6.1.4.1.4756.20.501.20.1.1609 | ColumnnidQOSPort2IngressFlowControlRemoteA | read-write | current | NID Series card QOS Port2 Ingress Flow Control 0: NO 1: YES |
| 1.3.6.1.4.1.4756.20.501.20.1.1610 | ColumnnidQOSPort3IngressRemoteA | read-write | current | NID Series card QOS Port3 Ingress Enabled 0: NO 1: YES |
| 1.3.6.1.4.1.4756.20.501.20.1.1611 | ColumnnidQOSPort3IngressRateRemoteA | read-write | current | NID Series card QOS Port3 Ingress Rate |
| 1.3.6.1.4.1.4756.20.501.20.1.1612 | ColumnnidQOSPort3IngressRateUnitRemoteA | read-write | current | NID Series card QOS Port3 Ingress Rate Unit 0: Kbps 1: Mbps 2: fps 3: kfps |
| 1.3.6.1.4.1.4756.20.501.20.1.1613 | ColumnnidQOSPort3IngressFlowControlRemoteA | read-write | current | NID Series card QOS Port3 Ingress Flow Control 0: NO 1: YES |
| 1.3.6.1.4.1.4756.20.501.20.1.1614 | ColumnnidQOSPort4IngressRemoteA | read-write | current | NID Series card QOS Port4 Ingress Enabled 0: NO 1: YES |
| 1.3.6.1.4.1.4756.20.501.20.1.1615 | ColumnnidQOSPort4IngressRateRemoteA | read-write | current | NID Series card QOS Port4 Ingress Rate |
| 1.3.6.1.4.1.4756.20.501.20.1.1616 | ColumnnidQOSPort4IngressRateUnitRemoteA | read-write | current | NID Series card QOS Port4 Ingress Rate Unit 0: Kbps 1: Mbps 2: fps 3: kfps |
| 1.3.6.1.4.1.4756.20.501.20.1.1617 | ColumnnidQOSPort4IngressFlowControlRemoteA | read-write | current | NID Series card QOS Port4 Ingress Flow Control 0: NO 1: YES |
| 1.3.6.1.4.1.4756.20.501.20.1.1618 | ColumnnidQOSPort5IngressRemoteA | read-write | current | NID Series card QOS Port5 Ingress Enabled 0: NO 1: YES |
| 1.3.6.1.4.1.4756.20.501.20.1.1619 | ColumnnidQOSPort5IngressRateRemoteA | read-write | current | NID Series card QOS Port5 Ingress Rate |
| 1.3.6.1.4.1.4756.20.501.20.1.1620 | ColumnnidQOSPort5IngressRateUnitRemoteA | read-write | current | NID Series card QOS Port5 Ingress Rate Unit 0: Kbps 1: Mbps 2: fps 3: kfps |
| 1.3.6.1.4.1.4756.20.501.20.1.1621 | ColumnnidQOSPort5IngressFlowControlRemoteA | read-write | current | NID Series card QOS Port5 Ingress Flow Control 0: NO 1: YES |
| 1.3.6.1.4.1.4756.20.501.20.1.1622 | ColumnnidQOSPort6IngressRemoteA | read-write | current | NID Series card QOS Port6 Ingress Enabled 0: NO 1: YES |
| 1.3.6.1.4.1.4756.20.501.20.1.1623 | ColumnnidQOSPort6IngressRateRemoteA | read-write | current | NID Series card QOS Port6 Ingress Rate |
| 1.3.6.1.4.1.4756.20.501.20.1.1624 | ColumnnidQOSPort6IngressRateUnitRemoteA | read-write | current | NID Series card QOS Port6 Ingress Rate Unit 0: Kbps 1: Mbps 2: fps 3: kfps |
| 1.3.6.1.4.1.4756.20.501.20.1.1625 | ColumnnidQOSPort6IngressFlowControlRemoteA | read-write | current | NID Series card QOS Port6 Ingress Flow Control 0: NO 1: YES |
| 1.3.6.1.4.1.4756.20.501.20.1.1626 | ColumnnidQOSPort7IngressRemoteA | read-write | current | NID Series card QOS Port7 Ingress Enabled 0: NO 1: YES |
| 1.3.6.1.4.1.4756.20.501.20.1.1627 | ColumnnidQOSPort7IngressRateRemoteA | read-write | current | NID Series card QOS Port7 Ingress Rate |
| 1.3.6.1.4.1.4756.20.501.20.1.1628 | ColumnnidQOSPort7IngressRateUnitRemoteA | read-write | current | NID Series card QOS Port7 Ingress Rate Unit 0: Kbps 1: Mbps 2: fps 3: kfps |
| 1.3.6.1.4.1.4756.20.501.20.1.1629 | ColumnnidQOSPort7IngressFlowControlRemoteA | read-write | current | NID Series card QOS Port7 Ingress Flow Control 0: NO 1: YES |
| 1.3.6.1.4.1.4756.20.501.20.1.1630 | ColumnnidQOSPort8IngressRemoteA | read-write | current | NID Series card QOS Port8 Ingress Enabled 0: NO 1: YES |
| 1.3.6.1.4.1.4756.20.501.20.1.1631 | ColumnnidQOSPort8IngressRateRemoteA | read-write | current | NID Series card QOS Port8 Ingress Rate |
| 1.3.6.1.4.1.4756.20.501.20.1.1632 | ColumnnidQOSPort8IngressRateUnitRemoteA | read-write | current | NID Series card QOS Port8 Ingress Rate Unit 0: Kbps 1: Mbps 2: fps 3: kfps |
| 1.3.6.1.4.1.4756.20.501.20.1.1633 | ColumnnidQOSPort8IngressFlowControlRemoteA | read-write | current | NID Series card QOS Port8 Ingress Flow Control 0: NO 1: YES |
| 1.3.6.1.4.1.4756.20.501.20.1.1634 | ColumnnidQOSPort1EgressRemoteA | read-write | current | NID Series card QOS Port1 Egress Enabled 0: NO 1: YES |
| 1.3.6.1.4.1.4756.20.501.20.1.1635 | ColumnnidQOSPort1EgressRateRemoteA | read-write | current | NID Series card QOS Port1 Egress Rate |
| 1.3.6.1.4.1.4756.20.501.20.1.1636 | ColumnnidQOSPort1EgressRateUnitRemoteA | read-write | current | NID Series card QOS Port1 Egress Rate Unit 0: Kbps 1: Mbps |
| 1.3.6.1.4.1.4756.20.501.20.1.1637 | ColumnnidQOSPort2EgressRemoteA | read-write | current | NID Series card QOS Port2 Egress Enabled 0: NO 1: YES |
| 1.3.6.1.4.1.4756.20.501.20.1.1638 | ColumnnidQOSPort2EgressRateRemoteA | read-write | current | NID Series card QOS Port2 Egress Rate |
| 1.3.6.1.4.1.4756.20.501.20.1.1639 | ColumnnidQOSPort2EgressRateUnitRemoteA | read-write | current | NID Series card QOS Port2 Egress Rate Unit 0: Kbps 1: Mbps |
| 1.3.6.1.4.1.4756.20.501.20.1.1640 | ColumnnidQOSPort3EgressRemoteA | read-write | current | NID Series card QOS Port3 Egress Enabled 0: NO 1: YES |
| 1.3.6.1.4.1.4756.20.501.20.1.1641 | ColumnnidQOSPort3EgressRateRemoteA | read-write | current | NID Series card QOS Port3 Egress Rate |
| 1.3.6.1.4.1.4756.20.501.20.1.1642 | ColumnnidQOSPort3EgressRateUnitRemoteA | read-write | current | NID Series card QOS Port3 Egress Rate Unit 0: Kbps 1: Mbps |
| 1.3.6.1.4.1.4756.20.501.20.1.1643 | ColumnnidQOSPort4EgressRemoteA | read-write | current | NID Series card QOS Port4 Egress Enabled 0: NO 1: YES |
| 1.3.6.1.4.1.4756.20.501.20.1.1644 | ColumnnidQOSPort4EgressRateRemoteA | read-write | current | NID Series card QOS Port4 Egress Rate |
| 1.3.6.1.4.1.4756.20.501.20.1.1645 | ColumnnidQOSPort4EgressRateUnitRemoteA | read-write | current | NID Series card QOS Port4 Egress Rate Unit 0: Kbps 1: Mbps |
| 1.3.6.1.4.1.4756.20.501.20.1.1646 | ColumnnidQOSPort5EgressRemoteA | read-write | current | NID Series card QOS Port5 Egress Enabled 0: NO 1: YES |
| 1.3.6.1.4.1.4756.20.501.20.1.1647 | ColumnnidQOSPort5EgressRateRemoteA | read-write | current | NID Series card QOS Port5 Egress Rate |
| 1.3.6.1.4.1.4756.20.501.20.1.1648 | ColumnnidQOSPort5EgressRateUnitRemoteA | read-write | current | NID Series card QOS Port5 Egress Rate Unit 0: Kbps 1: Mbps |
| 1.3.6.1.4.1.4756.20.501.20.1.1649 | ColumnnidQOSPort6EgressRemoteA | read-write | current | NID Series card QOS Port6 Egress Enabled 0: NO 1: YES |
| 1.3.6.1.4.1.4756.20.501.20.1.1650 | ColumnnidQOSPort6EgressRateRemoteA | read-write | current | NID Series card QOS Port6 Egress Rate |
| 1.3.6.1.4.1.4756.20.501.20.1.1651 | ColumnnidQOSPort6EgressRateUnitRemoteA | read-write | current | NID Series card QOS Port6 Egress Rate Unit 0: Kbps 1: Mbps |
| 1.3.6.1.4.1.4756.20.501.20.1.1652 | ColumnnidQOSPort7EgressRemoteA | read-write | current | NID Series card QOS Port7 Egress Enabled 0: NO 1: YES |
| 1.3.6.1.4.1.4756.20.501.20.1.1653 | ColumnnidQOSPort7EgressRateRemoteA | read-write | current | NID Series card QOS Port7 Egress Rate |
| 1.3.6.1.4.1.4756.20.501.20.1.1654 | ColumnnidQOSPort7EgressRateUnitRemoteA | read-write | current | NID Series card QOS Port7 Egress Rate Unit 0: Kbps 1: Mbps |
| 1.3.6.1.4.1.4756.20.501.20.1.1655 | ColumnnidQOSPort8EgressRemoteA | read-write | current | NID Series card QOS Port8 Egress Enabled 0: NO 1: YES |
| 1.3.6.1.4.1.4756.20.501.20.1.1656 | ColumnnidQOSPort8EgressRateRemoteA | read-write | current | NID Series card QOS Port8 Egress Rate |
| 1.3.6.1.4.1.4756.20.501.20.1.1657 | ColumnnidQOSPort8EgressRateUnitRemoteA | read-write | current | NID Series card QOS Port8 Egress Rate Unit 0: Kbps 1: Mbps |
| 1.3.6.1.4.1.4756.20.501.20.1.1658 | ColumnnidQOSUnicastRemoteA | read-write | current | NID Series card QOS Storm Control Configuration- Unicast 0: NO 1: YES |
| 1.3.6.1.4.1.4756.20.501.20.1.1659 | ColumnnidQOSUnicastRateRemoteA | read-write | current | NID Series card QOS Storm Control Configuration- Unicast Rate The rate unit is packets per second (pps). 0: 1 1: 2 2: 4 3: 8 4: 16 5: 32 6: 64 7: 128 8: 256 9:… |
| 1.3.6.1.4.1.4756.20.501.20.1.1660 | ColumnnidQOSMulticastRemoteA | read-write | current | NID Series card QOS Storm Control Configuration- Multicast 0: NO 1: YES |
| 1.3.6.1.4.1.4756.20.501.20.1.1661 | ColumnnidQOSMulticastRateRemoteA | read-write | current | NID Series card QOS Storm Control Configuration- Multicast The rate unit is packets per second (pps). 0: 1 1: 2 2: 4 3: 8 4: 16 5: 32 6: 64 7: 128 8: 256 9: 51… |
| 1.3.6.1.4.1.4756.20.501.20.1.1662 | ColumnnidQOSBroadcastRemoteA | read-write | current | NID Series card QOS Storm Control Configuration- Broadcast 0: NO 1: YES |
| 1.3.6.1.4.1.4756.20.501.20.1.1663 | ColumnnidQOSBroadcastRateRemoteA | read-write | current | NID Series card QOS Storm Control Configuration- Broadcast The rate unit is packets per second (pps). 0: 1 1: 2 2: 4 3: 8 4: 16 5: 32 6: 64 7: 128 8: 256 9: 51… |
| 1.3.6.1.4.1.4756.20.501.20.1.1664 | ColumnnidL2CPPort1DMAC0180C2000000RemoteA | read-write | current | NID Series card Port 1 L2CP Mode 0180C2000000 0: Forward 1: Discard 2: Peer |
| 1.3.6.1.4.1.4756.20.501.20.1.1665 | ColumnnidL2CPPort1DMAC0180C2000001RemoteA | read-write | current | NID Series card Port 1 L2CP Mode 0180C2000001 0: Forward 1: Discard 2: Peer |
| 1.3.6.1.4.1.4756.20.501.20.1.1666 | ColumnnidL2CPPort1DMAC0180C2000002RemoteA | read-write | current | NID Series card Port 1 L2CP Mode 0180C2000002 0: Forward 1: Discard 2: Peer |
| 1.3.6.1.4.1.4756.20.501.20.1.1667 | ColumnnidL2CPPort1DMAC0180C2000003RemoteA | read-write | current | NID Series card Port 1 L2CP Mode 0180C2000003 0: Forward 1: Discard 2: Peer |
| 1.3.6.1.4.1.4756.20.501.20.1.1668 | ColumnnidL2CPPort1DMAC0180C2000004RemoteA | read-write | current | NID Series card Port 1 L2CP Mode 0180C2000004 0: Forward 1: Discard 2: Peer |
| 1.3.6.1.4.1.4756.20.501.20.1.1669 | ColumnnidL2CPPort1DMAC0180C2000005RemoteA | read-write | current | NID Series card Port 1 L2CP Mode 0180C2000005 0: Forward 1: Discard 2: Peer |
| 1.3.6.1.4.1.4756.20.501.20.1.1670 | ColumnnidL2CPPort1DMAC0180C2000006RemoteA | read-write | current | NID Series card Port 1 L2CP Mode 0180C2000006 0: Forward 1: Discard 2: Peer |
| 1.3.6.1.4.1.4756.20.501.20.1.1671 | ColumnnidL2CPPort1DMAC0180C2000007RemoteA | read-write | current | NID Series card Port 1 L2CP Mode 0180C2000007 0: Forward 1: Discard 2: Peer |
| 1.3.6.1.4.1.4756.20.501.20.1.1672 | ColumnnidL2CPPort1DMAC0180C2000008RemoteA | read-write | current | NID Series card Port 1 L2CP Mode 0180C2000008 0: Forward 1: Discard 2: Peer |
| 1.3.6.1.4.1.4756.20.501.20.1.1673 | ColumnnidL2CPPort1DMAC0180C2000009RemoteA | read-write | current | NID Series card Port 1 L2CP Mode 0180C2000009 0: Forward 1: Discard 2: Peer |
| 1.3.6.1.4.1.4756.20.501.20.1.1674 | ColumnnidL2CPPort1DMAC0180C200000ARemoteA | read-write | current | NID Series card Port 1 L2CP Mode 0180C200000A 0: Forward 1: Discard 2: Peer |
| 1.3.6.1.4.1.4756.20.501.20.1.1675 | ColumnnidL2CPPort1DMAC0180C200000BRemoteA | read-write | current | NID Series card Port 1 L2CP Mode 0180C200000B 0: Forward 1: Discard 2: Peer |
| 1.3.6.1.4.1.4756.20.501.20.1.1676 | ColumnnidL2CPPort1DMAC0180C200000CRemoteA | read-write | current | NID Series card Port 1 L2CP Mode 0180C200000C 0: Forward 1: Discard 2: Peer |
| 1.3.6.1.4.1.4756.20.501.20.1.1677 | ColumnnidL2CPPort1DMAC0180C200000DRemoteA | read-write | current | NID Series card Port 1 L2CP Mode 0180C200000D 0: Forward 1: Discard 2: Peer |
| 1.3.6.1.4.1.4756.20.501.20.1.1678 | ColumnnidL2CPPort1DMAC0180C200000ERemoteA | read-write | current | NID Series card Port 1 L2CP Mode 0180C200000E 0: Forward 1: Discard 2: Peer |
| 1.3.6.1.4.1.4756.20.501.20.1.1679 | ColumnnidL2CPPort1DMAC0180C200000FRemoteA | read-write | current | NID Series card Port 1 L2CP Mode 0180C200000F 0: Forward 1: Discard 2: Peer |
| 1.3.6.1.4.1.4756.20.501.20.1.1680 | ColumnnidL2CPPort1DMAC0180C2000010RemoteA | read-write | current | NID Series card Port 1 L2CP Mode 0180C2000010 0: Forward 1: Discard 2: Peer |
| 1.3.6.1.4.1.4756.20.501.20.1.1681 | ColumnnidL2CPPort1DMAC0180C2000020RemoteA | read-write | current | NID Series card Port 1 L2CP Mode 0180C2000020 0: Forward 1: Discard 2: Peer |
| 1.3.6.1.4.1.4756.20.501.20.1.1682 | ColumnnidL2CPPort1DMAC0180C2000021RemoteA | read-write | current | NID Series card Port 1 L2CP Mode 0180C2000021 0: Forward 1: Discard 2: Peer |
| 1.3.6.1.4.1.4756.20.501.20.1.1683 | ColumnnidL2CPPort1DMAC0180C2000022RemoteA | read-write | current | NID Series card Port 1 L2CP Mode 0180C2000022 0: Forward 1: Discard 2: Peer |
| 1.3.6.1.4.1.4756.20.501.20.1.1684 | ColumnnidL2CPPort1DMAC0180C2000023RemoteA | read-write | current | NID Series card Port 1 L2CP Mode 0180C2000023 0: Forward 1: Discard 2: Peer |
| 1.3.6.1.4.1.4756.20.501.20.1.1685 | ColumnnidL2CPPort1DMAC0180C2000024RemoteA | read-write | current | NID Series card Port 1 L2CP Mode 0180C2000024 0: Forward 1: Discard 2: Peer |
| 1.3.6.1.4.1.4756.20.501.20.1.1686 | ColumnnidL2CPPort1DMAC0180C2000025RemoteA | read-write | current | NID Series card Port 1 L2CP Mode 0180C2000025 0: Forward 1: Discard 2: Peer |
| 1.3.6.1.4.1.4756.20.501.20.1.1687 | ColumnnidL2CPPort1DMAC0180C2000026RemoteA | read-write | current | NID Series card Port 1 L2CP Mode 0180C2000026 0: Forward 1: Discard 2: Peer |
| 1.3.6.1.4.1.4756.20.501.20.1.1688 | ColumnnidL2CPPort1DMAC0180C2000027RemoteA | read-write | current | NID Series card Port 1 L2CP Mode 0180C2000027 0: Forward 1: Discard 2: Peer |
| 1.3.6.1.4.1.4756.20.501.20.1.1689 | ColumnnidL2CPPort1DMAC0180C2000028RemoteA | read-write | current | NID Series card Port 1 L2CP Mode 0180C2000028 0: Forward 1: Discard 2: Peer |
| 1.3.6.1.4.1.4756.20.501.20.1.1690 | ColumnnidL2CPPort1DMAC0180C2000029RemoteA | read-write | current | NID Series card Port 1 L2CP Mode 0180C2000029 0: Forward 1: Discard 2: Peer |
| 1.3.6.1.4.1.4756.20.501.20.1.1691 | ColumnnidL2CPPort1DMAC0180C200002ARemoteA | read-write | current | NID Series card Port 1 L2CP Mode 0180C200002A 0: Forward 1: Discard 2: Peer |
| 1.3.6.1.4.1.4756.20.501.20.1.1692 | ColumnnidL2CPPort1DMAC0180C200002BRemoteA | read-write | current | NID Series card Port 1 L2CP Mode 0180C200002B 0: Forward 1: Discard 2: Peer |
| 1.3.6.1.4.1.4756.20.501.20.1.1693 | ColumnnidL2CPPort1DMAC0180C200002CRemoteA | read-write | current | NID Series card Port 1 L2CP Mode 0180C200002C 0: Forward 1: Discard 2: Peer |
| 1.3.6.1.4.1.4756.20.501.20.1.1694 | ColumnnidL2CPPort1DMAC0180C200002DRemoteA | read-write | current | NID Series card Port 1 L2CP Mode 0180C200002D 0: Forward 1: Discard 2: Peer |
| 1.3.6.1.4.1.4756.20.501.20.1.1695 | ColumnnidL2CPPort1DMAC0180C200002ERemoteA | read-write | current | NID Series card Port 1 L2CP Mode 0180C200002E 0: Forward 1: Discard 2: Peer |
| 1.3.6.1.4.1.4756.20.501.20.1.1696 | ColumnnidL2CPPort1DMAC0180C200002FRemoteA | read-write | current | NID Series card Port 1 L2CP Mode 0180C200002F 0: Forward 1: Discard 1: Peer |
| 1.3.6.1.4.1.4756.20.501.20.1.1697 | ColumnnidL2CPPort2DMAC0180C2000000RemoteA | read-write | current | NID Series card Port 2 L2CP Mode 0180C2000000 0: Forward 1: Discard 2: Peer |
| 1.3.6.1.4.1.4756.20.501.20.1.1698 | ColumnnidL2CPPort2DMAC0180C2000001RemoteA | read-write | current | NID Series card Port 2 L2CP Mode 0180C2000001 0: Forward 1: Discard 2: Peer |
| 1.3.6.1.4.1.4756.20.501.20.1.1699 | ColumnnidL2CPPort2DMAC0180C2000002RemoteA | read-write | current | NID Series card Port 2 L2CP Mode 0180C2000002 0: Forward 1: Discard 2: Peer |
| 1.3.6.1.4.1.4756.20.501.20.1.1700 | ColumnnidL2CPPort2DMAC0180C2000003RemoteA | read-write | current | NID Series card Port 2 L2CP Mode 0180C2000003 0: Forward 1: Discard 2: Peer |
| 1.3.6.1.4.1.4756.20.501.20.1.1701 | ColumnnidL2CPPort2DMAC0180C2000004RemoteA | read-write | current | NID Series card Port 2 L2CP Mode 0180C2000004 0: Forward 1: Discard 2: Peer |
| 1.3.6.1.4.1.4756.20.501.20.1.1702 | ColumnnidL2CPPort2DMAC0180C2000005RemoteA | read-write | current | NID Series card Port 2 L2CP Mode 0180C2000005 0: Forward 1: Discard 2: Peer |
| 1.3.6.1.4.1.4756.20.501.20.1.1703 | ColumnnidL2CPPort2DMAC0180C2000006RemoteA | read-write | current | NID Series card Port 2 L2CP Mode 0180C2000006 0: Forward 1: Discard 2: Peer |
| 1.3.6.1.4.1.4756.20.501.20.1.1704 | ColumnnidL2CPPort2DMAC0180C2000007RemoteA | read-write | current | NID Series card Port 2 L2CP Mode 0180C2000007 0: Forward 1: Discard 2: Peer |
| 1.3.6.1.4.1.4756.20.501.20.1.1705 | ColumnnidL2CPPort2DMAC0180C2000008RemoteA | read-write | current | NID Series card Port 2 L2CP Mode 0180C2000008 0: Forward 1: Discard 2: Peer |
| 1.3.6.1.4.1.4756.20.501.20.1.1706 | ColumnnidL2CPPort2DMAC0180C2000009RemoteA | read-write | current | NID Series card Port 2 L2CP Mode 0180C2000009 0: Forward 1: Discard 2: Peer |
| 1.3.6.1.4.1.4756.20.501.20.1.1707 | ColumnnidL2CPPort2DMAC0180C200000ARemoteA | read-write | current | NID Series card Port 2 L2CP Mode 0180C200000A 0: Forward 1: Discard 2: Peer |
| 1.3.6.1.4.1.4756.20.501.20.1.1708 | ColumnnidL2CPPort2DMAC0180C200000BRemoteA | read-write | current | NID Series card Port 2 L2CP Mode 0180C200000B 0: Forward 1: Discard 2: Peer |
| 1.3.6.1.4.1.4756.20.501.20.1.1709 | ColumnnidL2CPPort2DMAC0180C200000CRemoteA | read-write | current | NID Series card Port 2 L2CP Mode 0180C200000C 0: Forward 1: Discard 2: Peer |
| 1.3.6.1.4.1.4756.20.501.20.1.1710 | ColumnnidL2CPPort2DMAC0180C200000DRemoteA | read-write | current | NID Series card Port 2 L2CP Mode 0180C200000D 0: Forward 1: Discard 2: Peer |
| 1.3.6.1.4.1.4756.20.501.20.1.1711 | ColumnnidL2CPPort2DMAC0180C200000ERemoteA | read-write | current | NID Series card Port 2 L2CP Mode 0180C200000E 0: Forward 1: Discard 2: Peer |
| 1.3.6.1.4.1.4756.20.501.20.1.1712 | ColumnnidL2CPPort2DMAC0180C200000FRemoteA | read-write | current | NID Series card Port 2 L2CP Mode 0180C200000F 0: Forward 1: Discard 2: Peer |
| 1.3.6.1.4.1.4756.20.501.20.1.1713 | ColumnnidL2CPPort2DMAC0180C2000010RemoteA | read-write | current | NID Series card Port 2 L2CP Mode 0180C2000010 0: Forward 1: Discard 2: Peer |
| 1.3.6.1.4.1.4756.20.501.20.1.1714 | ColumnnidL2CPPort2DMAC0180C2000020RemoteA | read-write | current | NID Series card Port 2 L2CP Mode 0180C2000020 0: Forward 1: Discard 2: Peer |
| 1.3.6.1.4.1.4756.20.501.20.1.1715 | ColumnnidL2CPPort2DMAC0180C2000021RemoteA | read-write | current | NID Series card Port 2 L2CP Mode 0180C2000021 0: Forward 1: Discard 2: Peer |
| 1.3.6.1.4.1.4756.20.501.20.1.1716 | ColumnnidL2CPPort2DMAC0180C2000022RemoteA | read-write | current | NID Series card Port 2 L2CP Mode 0180C2000022 0: Forward 1: Discard 2: Peer |
| 1.3.6.1.4.1.4756.20.501.20.1.1717 | ColumnnidL2CPPort2DMAC0180C2000023RemoteA | read-write | current | NID Series card Port 2 L2CP Mode 0180C2000023 0: Forward 1: Discard 2: Peer |
| 1.3.6.1.4.1.4756.20.501.20.1.1718 | ColumnnidL2CPPort2DMAC0180C2000024RemoteA | read-write | current | NID Series card Port 2 L2CP Mode 0180C2000024 0: Forward 1: Discard 2: Peer |
| 1.3.6.1.4.1.4756.20.501.20.1.1719 | ColumnnidL2CPPort2DMAC0180C2000025RemoteA | read-write | current | NID Series card Port 2 L2CP Mode 0180C2000025 0: Forward 1: Discard 2: Peer |
| 1.3.6.1.4.1.4756.20.501.20.1.1720 | ColumnnidL2CPPort2DMAC0180C2000026RemoteA | read-write | current | NID Series card Port 2 L2CP Mode 0180C2000026 0: Forward 1: Discard 2: Peer |
| 1.3.6.1.4.1.4756.20.501.20.1.1721 | ColumnnidL2CPPort2DMAC0180C2000027RemoteA | read-write | current | NID Series card Port 2 L2CP Mode 0180C2000027 0: Forward 1: Discard 2: Peer |
| 1.3.6.1.4.1.4756.20.501.20.1.1722 | ColumnnidL2CPPort2DMAC0180C2000028RemoteA | read-write | current | NID Series card Port 2 L2CP Mode 0180C2000028 0: Forward 1: Discard 2: Peer |
| 1.3.6.1.4.1.4756.20.501.20.1.1723 | ColumnnidL2CPPort2DMAC0180C2000029RemoteA | read-write | current | NID Series card Port 2 L2CP Mode 0180C2000029 0: Forward 1: Discard 2: Peer |
| 1.3.6.1.4.1.4756.20.501.20.1.1724 | ColumnnidL2CPPort2DMAC0180C200002ARemoteA | read-write | current | NID Series card Port 2 L2CP Mode 0180C200002A 0: Forward 1: Discard 2: Peer |
| 1.3.6.1.4.1.4756.20.501.20.1.1725 | ColumnnidL2CPPort2DMAC0180C200002BRemoteA | read-write | current | NID Series card Port 2 L2CP Mode 0180C200002B 0: Forward 1: Discard 2: Peer |
| 1.3.6.1.4.1.4756.20.501.20.1.1726 | ColumnnidL2CPPort2DMAC0180C200002CRemoteA | read-write | current | NID Series card Port 2 L2CP Mode 0180C200002C 0: Forward 1: Discard 2: Peer |
| 1.3.6.1.4.1.4756.20.501.20.1.1727 | ColumnnidL2CPPort2DMAC0180C200002DRemoteA | read-write | current | NID Series card Port 2 L2CP Mode 0180C200002D 0: Forward 1: Discard 2: Peer |
| 1.3.6.1.4.1.4756.20.501.20.1.1728 | ColumnnidL2CPPort2DMAC0180C200002ERemoteA | read-write | current | NID Series card Port 2 L2CP Mode 0180C200002E 0: Forward 1: Discard 2: Peer |
| 1.3.6.1.4.1.4756.20.501.20.1.1729 | ColumnnidL2CPPort2DMAC0180C200002FRemoteA | read-write | current | NID Series card Port 2 L2CP Mode 0180C200002F 0: Forward 1: Discard 1: Peer |
| 1.3.6.1.4.1.4756.20.501.20.1.1730 | ColumnnidL2CPPort3DMAC0180C2000000RemoteA | read-write | current | NID Series card Port 3 L2CP Mode 0180C2000000 0: Forward 1: Discard 2: Peer |
| 1.3.6.1.4.1.4756.20.501.20.1.1731 | ColumnnidL2CPPort3DMAC0180C2000001RemoteA | read-write | current | NID Series card Port 3 L2CP Mode 0180C2000001 0: Forward 1: Discard 2: Peer |
| 1.3.6.1.4.1.4756.20.501.20.1.1732 | ColumnnidL2CPPort3DMAC0180C2000002RemoteA | read-write | current | NID Series card Port 3 L2CP Mode 0180C2000002 0: Forward 1: Discard 2: Peer |
| 1.3.6.1.4.1.4756.20.501.20.1.1733 | ColumnnidL2CPPort3DMAC0180C2000003RemoteA | read-write | current | NID Series card Port 3 L2CP Mode 0180C2000003 0: Forward 1: Discard 2: Peer |
| 1.3.6.1.4.1.4756.20.501.20.1.1734 | ColumnnidL2CPPort3DMAC0180C2000004RemoteA | read-write | current | NID Series card Port 3 L2CP Mode 0180C2000004 0: Forward 1: Discard 2: Peer |
| 1.3.6.1.4.1.4756.20.501.20.1.1735 | ColumnnidL2CPPort3DMAC0180C2000005RemoteA | read-write | current | NID Series card Port 3 L2CP Mode 0180C2000005 0: Forward 1: Discard 2: Peer |
| 1.3.6.1.4.1.4756.20.501.20.1.1736 | ColumnnidL2CPPort3DMAC0180C2000006RemoteA | read-write | current | NID Series card Port 3 L2CP Mode 0180C2000006 0: Forward 1: Discard 2: Peer |
| 1.3.6.1.4.1.4756.20.501.20.1.1737 | ColumnnidL2CPPort3DMAC0180C2000007RemoteA | read-write | current | NID Series card Port 3 L2CP Mode 0180C2000007 0: Forward 1: Discard 2: Peer |
| 1.3.6.1.4.1.4756.20.501.20.1.1738 | ColumnnidL2CPPort3DMAC0180C2000008RemoteA | read-write | current | NID Series card Port 3 L2CP Mode 0180C2000008 0: Forward 1: Discard 2: Peer |
| 1.3.6.1.4.1.4756.20.501.20.1.1739 | ColumnnidL2CPPort3DMAC0180C2000009RemoteA | read-write | current | NID Series card Port 3 L2CP Mode 0180C2000009 0: Forward 1: Discard 2: Peer |
| 1.3.6.1.4.1.4756.20.501.20.1.1740 | ColumnnidL2CPPort3DMAC0180C200000ARemoteA | read-write | current | NID Series card Port 3 L2CP Mode 0180C200000A 0: Forward 1: Discard 2: Peer |
| 1.3.6.1.4.1.4756.20.501.20.1.1741 | ColumnnidL2CPPort3DMAC0180C200000BRemoteA | read-write | current | NID Series card Port 3 L2CP Mode 0180C200000B 0: Forward 1: Discard 2: Peer |
| 1.3.6.1.4.1.4756.20.501.20.1.1742 | ColumnnidL2CPPort3DMAC0180C200000CRemoteA | read-write | current | NID Series card Port 3 L2CP Mode 0180C200000C 0: Forward 1: Discard 2: Peer |
| 1.3.6.1.4.1.4756.20.501.20.1.1743 | ColumnnidL2CPPort3DMAC0180C200000DRemoteA | read-write | current | NID Series card Port 3 L2CP Mode 0180C200000D 0: Forward 1: Discard 2: Peer |
| 1.3.6.1.4.1.4756.20.501.20.1.1744 | ColumnnidL2CPPort3DMAC0180C200000ERemoteA | read-write | current | NID Series card Port 3 L2CP Mode 0180C200000E 0: Forward 1: Discard 2: Peer |
| 1.3.6.1.4.1.4756.20.501.20.1.1745 | ColumnnidL2CPPort3DMAC0180C200000FRemoteA | read-write | current | NID Series card Port 3 L2CP Mode 0180C200000F 0: Forward 1: Discard 2: Peer |
| 1.3.6.1.4.1.4756.20.501.20.1.1746 | ColumnnidL2CPPort3DMAC0180C2000010RemoteA | read-write | current | NID Series card Port 3 L2CP Mode 0180C2000010 0: Forward 1: Discard 2: Peer |
| 1.3.6.1.4.1.4756.20.501.20.1.1747 | ColumnnidL2CPPort3DMAC0180C2000020RemoteA | read-write | current | NID Series card Port 3 L2CP Mode 0180C2000020 0: Forward 1: Discard 2: Peer |
| 1.3.6.1.4.1.4756.20.501.20.1.1748 | ColumnnidL2CPPort3DMAC0180C2000021RemoteA | read-write | current | NID Series card Port 3 L2CP Mode 0180C2000021 0: Forward 1: Discard 2: Peer |
| 1.3.6.1.4.1.4756.20.501.20.1.1749 | ColumnnidL2CPPort3DMAC0180C2000022RemoteA | read-write | current | NID Series card Port 3 L2CP Mode 0180C2000022 0: Forward 1: Discard 2: Peer |
| 1.3.6.1.4.1.4756.20.501.20.1.1750 | ColumnnidL2CPPort3DMAC0180C2000023RemoteA | read-write | current | NID Series card Port 3 L2CP Mode 0180C2000023 0: Forward 1: Discard 2: Peer |
| 1.3.6.1.4.1.4756.20.501.20.1.1751 | ColumnnidL2CPPort3DMAC0180C2000024RemoteA | read-write | current | NID Series card Port 3 L2CP Mode 0180C2000024 0: Forward 1: Discard 2: Peer |
| 1.3.6.1.4.1.4756.20.501.20.1.1752 | ColumnnidL2CPPort3DMAC0180C2000025RemoteA | read-write | current | NID Series card Port 3 L2CP Mode 0180C2000025 0: Forward 1: Discard 2: Peer |
| 1.3.6.1.4.1.4756.20.501.20.1.1753 | ColumnnidL2CPPort3DMAC0180C2000026RemoteA | read-write | current | NID Series card Port 3 L2CP Mode 0180C2000026 0: Forward 1: Discard 2: Peer |
| 1.3.6.1.4.1.4756.20.501.20.1.1754 | ColumnnidL2CPPort3DMAC0180C2000027RemoteA | read-write | current | NID Series card Port 3 L2CP Mode 0180C2000027 0: Forward 1: Discard 2: Peer |
| 1.3.6.1.4.1.4756.20.501.20.1.1755 | ColumnnidL2CPPort3DMAC0180C2000028RemoteA | read-write | current | NID Series card Port 3 L2CP Mode 0180C2000028 0: Forward 1: Discard 2: Peer |
| 1.3.6.1.4.1.4756.20.501.20.1.1756 | ColumnnidL2CPPort3DMAC0180C2000029RemoteA | read-write | current | NID Series card Port 3 L2CP Mode 0180C2000029 0: Forward 1: Discard 2: Peer |
| 1.3.6.1.4.1.4756.20.501.20.1.1757 | ColumnnidL2CPPort3DMAC0180C200002ARemoteA | read-write | current | NID Series card Port 3 L2CP Mode 0180C200002A 0: Forward 1: Discard 2: Peer |
| 1.3.6.1.4.1.4756.20.501.20.1.1758 | ColumnnidL2CPPort3DMAC0180C200002BRemoteA | read-write | current | NID Series card Port 3 L2CP Mode 0180C200002B 0: Forward 1: Discard 2: Peer |
| 1.3.6.1.4.1.4756.20.501.20.1.1759 | ColumnnidL2CPPort3DMAC0180C200002CRemoteA | read-write | current | NID Series card Port 3 L2CP Mode 0180C200002C 0: Forward 1: Discard 2: Peer |
| 1.3.6.1.4.1.4756.20.501.20.1.1760 | ColumnnidL2CPPort3DMAC0180C200002DRemoteA | read-write | current | NID Series card Port 3 L2CP Mode 0180C200002D 0: Forward 1: Discard 2: Peer |
| 1.3.6.1.4.1.4756.20.501.20.1.1761 | ColumnnidL2CPPort3DMAC0180C200002ERemoteA | read-write | current | NID Series card Port 3 L2CP Mode 0180C200002E 0: Forward 1: Discard 2: Peer |
| 1.3.6.1.4.1.4756.20.501.20.1.1762 | ColumnnidL2CPPort3DMAC0180C200002FRemoteA | read-write | current | NID Series card Port 3 L2CP Mode 0180C200002F 0: Forward 1: Discard 1: Peer |
| 1.3.6.1.4.1.4756.20.501.20.1.1763 | ColumnnidL2CPPort4DMAC0180C2000000RemoteA | read-write | current | NID Series card Port 4 L2CP Mode 0180C2000000 0: Forward 1: Discard 2: Peer |
| 1.3.6.1.4.1.4756.20.501.20.1.1764 | ColumnnidL2CPPort4DMAC0180C2000001RemoteA | read-write | current | NID Series card Port 4 L2CP Mode 0180C2000001 0: Forward 1: Discard 2: Peer |
| 1.3.6.1.4.1.4756.20.501.20.1.1765 | ColumnnidL2CPPort4DMAC0180C2000002RemoteA | read-write | current | NID Series card Port 4 L2CP Mode 0180C2000002 0: Forward 1: Discard 2: Peer |
| 1.3.6.1.4.1.4756.20.501.20.1.1766 | ColumnnidL2CPPort4DMAC0180C2000003RemoteA | read-write | current | NID Series card Port 4 L2CP Mode 0180C2000003 0: Forward 1: Discard 2: Peer |
| 1.3.6.1.4.1.4756.20.501.20.1.1767 | ColumnnidL2CPPort4DMAC0180C2000004RemoteA | read-write | current | NID Series card Port 4 L2CP Mode 0180C2000004 0: Forward 1: Discard 2: Peer |
| 1.3.6.1.4.1.4756.20.501.20.1.1768 | ColumnnidL2CPPort4DMAC0180C2000005RemoteA | read-write | current | NID Series card Port 4 L2CP Mode 0180C2000005 0: Forward 1: Discard 2: Peer |
| 1.3.6.1.4.1.4756.20.501.20.1.1769 | ColumnnidL2CPPort4DMAC0180C2000006RemoteA | read-write | current | NID Series card Port 4 L2CP Mode 0180C2000006 0: Forward 1: Discard 2: Peer |
| 1.3.6.1.4.1.4756.20.501.20.1.1770 | ColumnnidL2CPPort4DMAC0180C2000007RemoteA | read-write | current | NID Series card Port 4 L2CP Mode 0180C2000007 0: Forward 1: Discard 2: Peer |
| 1.3.6.1.4.1.4756.20.501.20.1.1771 | ColumnnidL2CPPort4DMAC0180C2000008RemoteA | read-write | current | NID Series card Port 4 L2CP Mode 0180C2000008 0: Forward 1: Discard 2: Peer |
| 1.3.6.1.4.1.4756.20.501.20.1.1772 | ColumnnidL2CPPort4DMAC0180C2000009RemoteA | read-write | current | NID Series card Port 4 L2CP Mode 0180C2000009 0: Forward 1: Discard 2: Peer |
| 1.3.6.1.4.1.4756.20.501.20.1.1773 | ColumnnidL2CPPort4DMAC0180C200000ARemoteA | read-write | current | NID Series card Port 4 L2CP Mode 0180C200000A 0: Forward 1: Discard 2: Peer |
| 1.3.6.1.4.1.4756.20.501.20.1.1774 | ColumnnidL2CPPort4DMAC0180C200000BRemoteA | read-write | current | NID Series card Port 4 L2CP Mode 0180C200000B 0: Forward 1: Discard 2: Peer |
| 1.3.6.1.4.1.4756.20.501.20.1.1775 | ColumnnidL2CPPort4DMAC0180C200000CRemoteA | read-write | current | NID Series card Port 4 L2CP Mode 0180C200000C 0: Forward 1: Discard 2: Peer |
| 1.3.6.1.4.1.4756.20.501.20.1.1776 | ColumnnidL2CPPort4DMAC0180C200000DRemoteA | read-write | current | NID Series card Port 4 L2CP Mode 0180C200000D 0: Forward 1: Discard 2: Peer |
| 1.3.6.1.4.1.4756.20.501.20.1.1777 | ColumnnidL2CPPort4DMAC0180C200000ERemoteA | read-write | current | NID Series card Port 4 L2CP Mode 0180C200000E 0: Forward 1: Discard 2: Peer |
| 1.3.6.1.4.1.4756.20.501.20.1.1778 | ColumnnidL2CPPort4DMAC0180C200000FRemoteA | read-write | current | NID Series card Port 4 L2CP Mode 0180C200000F 0: Forward 1: Discard 2: Peer |
| 1.3.6.1.4.1.4756.20.501.20.1.1779 | ColumnnidL2CPPort4DMAC0180C2000010RemoteA | read-write | current | NID Series card Port 4 L2CP Mode 0180C2000010 0: Forward 1: Discard 2: Peer |
| 1.3.6.1.4.1.4756.20.501.20.1.1780 | ColumnnidL2CPPort4DMAC0180C2000020RemoteA | read-write | current | NID Series card Port 4 L2CP Mode 0180C2000020 0: Forward 1: Discard 2: Peer |
| 1.3.6.1.4.1.4756.20.501.20.1.1781 | ColumnnidL2CPPort4DMAC0180C2000021RemoteA | read-write | current | NID Series card Port 4 L2CP Mode 0180C2000021 0: Forward 1: Discard 2: Peer |
| 1.3.6.1.4.1.4756.20.501.20.1.1782 | ColumnnidL2CPPort4DMAC0180C2000022RemoteA | read-write | current | NID Series card Port 4 L2CP Mode 0180C2000022 0: Forward 1: Discard 2: Peer |
| 1.3.6.1.4.1.4756.20.501.20.1.1783 | ColumnnidL2CPPort4DMAC0180C2000023RemoteA | read-write | current | NID Series card Port 4 L2CP Mode 0180C2000023 0: Forward 1: Discard 2: Peer |
| 1.3.6.1.4.1.4756.20.501.20.1.1784 | ColumnnidL2CPPort4DMAC0180C2000024RemoteA | read-write | current | NID Series card Port 4 L2CP Mode 0180C2000024 0: Forward 1: Discard 2: Peer |
| 1.3.6.1.4.1.4756.20.501.20.1.1785 | ColumnnidL2CPPort4DMAC0180C2000025RemoteA | read-write | current | NID Series card Port 4 L2CP Mode 0180C2000025 0: Forward 1: Discard 2: Peer |
| 1.3.6.1.4.1.4756.20.501.20.1.1786 | ColumnnidL2CPPort4DMAC0180C2000026RemoteA | read-write | current | NID Series card Port 4 L2CP Mode 0180C2000026 0: Forward 1: Discard 2: Peer |
| 1.3.6.1.4.1.4756.20.501.20.1.1787 | ColumnnidL2CPPort4DMAC0180C2000027RemoteA | read-write | current | NID Series card Port 4 L2CP Mode 0180C2000027 0: Forward 1: Discard 2: Peer |
| 1.3.6.1.4.1.4756.20.501.20.1.1788 | ColumnnidL2CPPort4DMAC0180C2000028RemoteA | read-write | current | NID Series card Port 4 L2CP Mode 0180C2000028 0: Forward 1: Discard 2: Peer |
| 1.3.6.1.4.1.4756.20.501.20.1.1789 | ColumnnidL2CPPort4DMAC0180C2000029RemoteA | read-write | current | NID Series card Port 4 L2CP Mode 0180C2000029 0: Forward 1: Discard 2: Peer |
| 1.3.6.1.4.1.4756.20.501.20.1.1790 | ColumnnidL2CPPort4DMAC0180C200002ARemoteA | read-write | current | NID Series card Port 4 L2CP Mode 0180C200002A 0: Forward 1: Discard 2: Peer |
| 1.3.6.1.4.1.4756.20.501.20.1.1791 | ColumnnidL2CPPort4DMAC0180C200002BRemoteA | read-write | current | NID Series card Port 4 L2CP Mode 0180C200002B 0: Forward 1: Discard 2: Peer |
| 1.3.6.1.4.1.4756.20.501.20.1.1792 | ColumnnidL2CPPort4DMAC0180C200002CRemoteA | read-write | current | NID Series card Port 4 L2CP Mode 0180C200002C 0: Forward 1: Discard 2: Peer |
| 1.3.6.1.4.1.4756.20.501.20.1.1793 | ColumnnidL2CPPort4DMAC0180C200002DRemoteA | read-write | current | NID Series card Port 4 L2CP Mode 0180C200002D 0: Forward 1: Discard 2: Peer |
| 1.3.6.1.4.1.4756.20.501.20.1.1794 | ColumnnidL2CPPort4DMAC0180C200002ERemoteA | read-write | current | NID Series card Port 4 L2CP Mode 0180C200002E 0: Forward 1: Discard 2: Peer |
| 1.3.6.1.4.1.4756.20.501.20.1.1795 | ColumnnidL2CPPort4DMAC0180C200002FRemoteA | read-write | current | NID Series card Port 4 L2CP Mode 0180C200002F 0: Forward 1: Discard 1: Peer |
| 1.3.6.1.4.1.4756.20.501.20.1.1796 | ColumnnidL2CPPort5DMAC0180C2000000RemoteA | read-write | current | NID Series card Port 5 L2CP Mode 0180C2000000 0: Forward 1: Discard 2: Peer |
| 1.3.6.1.4.1.4756.20.501.20.1.1797 | ColumnnidL2CPPort5DMAC0180C2000001RemoteA | read-write | current | NID Series card Port 5 L2CP Mode 0180C2000001 0: Forward 1: Discard 2: Peer |
| 1.3.6.1.4.1.4756.20.501.20.1.1798 | ColumnnidL2CPPort5DMAC0180C2000002RemoteA | read-write | current | NID Series card Port 5 L2CP Mode 0180C2000002 0: Forward 1: Discard 2: Peer |
| 1.3.6.1.4.1.4756.20.501.20.1.1799 | ColumnnidL2CPPort5DMAC0180C2000003RemoteA | read-write | current | NID Series card Port 5 L2CP Mode 0180C2000003 0: Forward 1: Discard 2: Peer |
| 1.3.6.1.4.1.4756.20.501.20.1.1800 | ColumnnidL2CPPort5DMAC0180C2000004RemoteA | read-write | current | NID Series card Port 5 L2CP Mode 0180C2000004 0: Forward 1: Discard 2: Peer |
| 1.3.6.1.4.1.4756.20.501.20.1.1801 | ColumnnidL2CPPort5DMAC0180C2000005RemoteA | read-write | current | NID Series card Port 5 L2CP Mode 0180C2000005 0: Forward 1: Discard 2: Peer |
| 1.3.6.1.4.1.4756.20.501.20.1.1802 | ColumnnidL2CPPort5DMAC0180C2000006RemoteA | read-write | current | NID Series card Port 5 L2CP Mode 0180C2000006 0: Forward 1: Discard 2: Peer |
| 1.3.6.1.4.1.4756.20.501.20.1.1803 | ColumnnidL2CPPort5DMAC0180C2000007RemoteA | read-write | current | NID Series card Port 5 L2CP Mode 0180C2000007 0: Forward 1: Discard 2: Peer |
| 1.3.6.1.4.1.4756.20.501.20.1.1804 | ColumnnidL2CPPort5DMAC0180C2000008RemoteA | read-write | current | NID Series card Port 5 L2CP Mode 0180C2000008 0: Forward 1: Discard 2: Peer |
| 1.3.6.1.4.1.4756.20.501.20.1.1805 | ColumnnidL2CPPort5DMAC0180C2000009RemoteA | read-write | current | NID Series card Port 5 L2CP Mode 0180C2000009 0: Forward 1: Discard 2: Peer |
| 1.3.6.1.4.1.4756.20.501.20.1.1806 | ColumnnidL2CPPort5DMAC0180C200000ARemoteA | read-write | current | NID Series card Port 5 L2CP Mode 0180C200000A 0: Forward 1: Discard 2: Peer |
| 1.3.6.1.4.1.4756.20.501.20.1.1807 | ColumnnidL2CPPort5DMAC0180C200000BRemoteA | read-write | current | NID Series card Port 5 L2CP Mode 0180C200000B 0: Forward 1: Discard 2: Peer |
| 1.3.6.1.4.1.4756.20.501.20.1.1808 | ColumnnidL2CPPort5DMAC0180C200000CRemoteA | read-write | current | NID Series card Port 5 L2CP Mode 0180C200000C 0: Forward 1: Discard 2: Peer |
| 1.3.6.1.4.1.4756.20.501.20.1.1809 | ColumnnidL2CPPort5DMAC0180C200000DRemoteA | read-write | current | NID Series card Port 5 L2CP Mode 0180C200000D 0: Forward 1: Discard 2: Peer |
| 1.3.6.1.4.1.4756.20.501.20.1.1810 | ColumnnidL2CPPort5DMAC0180C200000ERemoteA | read-write | current | NID Series card Port 5 L2CP Mode 0180C200000E 0: Forward 1: Discard 2: Peer |
| 1.3.6.1.4.1.4756.20.501.20.1.1811 | ColumnnidL2CPPort5DMAC0180C200000FRemoteA | read-write | current | NID Series card Port 5 L2CP Mode 0180C200000F 0: Forward 1: Discard 2: Peer |
| 1.3.6.1.4.1.4756.20.501.20.1.1812 | ColumnnidL2CPPort5DMAC0180C2000010RemoteA | read-write | current | NID Series card Port 5 L2CP Mode 0180C2000010 0: Forward 1: Discard 2: Peer |
| 1.3.6.1.4.1.4756.20.501.20.1.1813 | ColumnnidL2CPPort5DMAC0180C2000020RemoteA | read-write | current | NID Series card Port 5 L2CP Mode 0180C2000020 0: Forward 1: Discard 2: Peer |
| 1.3.6.1.4.1.4756.20.501.20.1.1814 | ColumnnidL2CPPort5DMAC0180C2000021RemoteA | read-write | current | NID Series card Port 5 L2CP Mode 0180C2000021 0: Forward 1: Discard 2: Peer |
| 1.3.6.1.4.1.4756.20.501.20.1.1815 | ColumnnidL2CPPort5DMAC0180C2000022RemoteA | read-write | current | NID Series card Port 5 L2CP Mode 0180C2000022 0: Forward 1: Discard 2: Peer |
| 1.3.6.1.4.1.4756.20.501.20.1.1816 | ColumnnidL2CPPort5DMAC0180C2000023RemoteA | read-write | current | NID Series card Port 5 L2CP Mode 0180C2000023 0: Forward 1: Discard 2: Peer |
| 1.3.6.1.4.1.4756.20.501.20.1.1817 | ColumnnidL2CPPort5DMAC0180C2000024RemoteA | read-write | current | NID Series card Port 5 L2CP Mode 0180C2000024 0: Forward 1: Discard 2: Peer |
| 1.3.6.1.4.1.4756.20.501.20.1.1818 | ColumnnidL2CPPort5DMAC0180C2000025RemoteA | read-write | current | NID Series card Port 5 L2CP Mode 0180C2000025 0: Forward 1: Discard 2: Peer |
| 1.3.6.1.4.1.4756.20.501.20.1.1819 | ColumnnidL2CPPort5DMAC0180C2000026RemoteA | read-write | current | NID Series card Port 5 L2CP Mode 0180C2000026 0: Forward 1: Discard 2: Peer |
| 1.3.6.1.4.1.4756.20.501.20.1.1820 | ColumnnidL2CPPort5DMAC0180C2000027RemoteA | read-write | current | NID Series card Port 5 L2CP Mode 0180C2000027 0: Forward 1: Discard 2: Peer |
| 1.3.6.1.4.1.4756.20.501.20.1.1821 | ColumnnidL2CPPort5DMAC0180C2000028RemoteA | read-write | current | NID Series card Port 5 L2CP Mode 0180C2000028 0: Forward 1: Discard 2: Peer |
| 1.3.6.1.4.1.4756.20.501.20.1.1822 | ColumnnidL2CPPort5DMAC0180C2000029RemoteA | read-write | current | NID Series card Port 5 L2CP Mode 0180C2000029 0: Forward 1: Discard 2: Peer |
| 1.3.6.1.4.1.4756.20.501.20.1.1823 | ColumnnidL2CPPort5DMAC0180C200002ARemoteA | read-write | current | NID Series card Port 5 L2CP Mode 0180C200002A 0: Forward 1: Discard 2: Peer |
| 1.3.6.1.4.1.4756.20.501.20.1.1824 | ColumnnidL2CPPort5DMAC0180C200002BRemoteA | read-write | current | NID Series card Port 5 L2CP Mode 0180C200002B 0: Forward 1: Discard 2: Peer |
| 1.3.6.1.4.1.4756.20.501.20.1.1825 | ColumnnidL2CPPort5DMAC0180C200002CRemoteA | read-write | current | NID Series card Port 5 L2CP Mode 0180C200002C 0: Forward 1: Discard 2: Peer |
| 1.3.6.1.4.1.4756.20.501.20.1.1826 | ColumnnidL2CPPort5DMAC0180C200002DRemoteA | read-write | current | NID Series card Port 5 L2CP Mode 0180C200002D 0: Forward 1: Discard 2: Peer |
| 1.3.6.1.4.1.4756.20.501.20.1.1827 | ColumnnidL2CPPort5DMAC0180C200002ERemoteA | read-write | current | NID Series card Port 5 L2CP Mode 0180C200002E 0: Forward 1: Discard 2: Peer |
| 1.3.6.1.4.1.4756.20.501.20.1.1828 | ColumnnidL2CPPort5DMAC0180C200002FRemoteA | read-write | current | NID Series card Port 5 L2CP Mode 0180C200002F 0: Forward 1: Discard 1: Peer |
| 1.3.6.1.4.1.4756.20.501.20.1.1829 | ColumnnidL2CPPort6DMAC0180C2000000RemoteA | read-write | current | NID Series card Port 6 L2CP Mode 0180C2000000 0: Forward 1: Discard 2: Peer |
| 1.3.6.1.4.1.4756.20.501.20.1.1830 | ColumnnidL2CPPort6DMAC0180C2000001RemoteA | read-write | current | NID Series card Port 6 L2CP Mode 0180C2000001 0: Forward 1: Discard 2: Peer |
| 1.3.6.1.4.1.4756.20.501.20.1.1831 | ColumnnidL2CPPort6DMAC0180C2000002RemoteA | read-write | current | NID Series card Port 6 L2CP Mode 0180C2000002 0: Forward 1: Discard 2: Peer |
| 1.3.6.1.4.1.4756.20.501.20.1.1832 | ColumnnidL2CPPort6DMAC0180C2000003RemoteA | read-write | current | NID Series card Port 6 L2CP Mode 0180C2000003 0: Forward 1: Discard 2: Peer |
| 1.3.6.1.4.1.4756.20.501.20.1.1833 | ColumnnidL2CPPort6DMAC0180C2000004RemoteA | read-write | current | NID Series card Port 6 L2CP Mode 0180C2000004 0: Forward 1: Discard 2: Peer |
| 1.3.6.1.4.1.4756.20.501.20.1.1834 | ColumnnidL2CPPort6DMAC0180C2000005RemoteA | read-write | current | NID Series card Port 6 L2CP Mode 0180C2000005 0: Forward 1: Discard 2: Peer |
| 1.3.6.1.4.1.4756.20.501.20.1.1835 | ColumnnidL2CPPort6DMAC0180C2000006RemoteA | read-write | current | NID Series card Port 6 L2CP Mode 0180C2000006 0: Forward 1: Discard 2: Peer |
| 1.3.6.1.4.1.4756.20.501.20.1.1836 | ColumnnidL2CPPort6DMAC0180C2000007RemoteA | read-write | current | NID Series card Port 6 L2CP Mode 0180C2000007 0: Forward 1: Discard 2: Peer |
| 1.3.6.1.4.1.4756.20.501.20.1.1837 | ColumnnidL2CPPort6DMAC0180C2000008RemoteA | read-write | current | NID Series card Port 6 L2CP Mode 0180C2000008 0: Forward 1: Discard 2: Peer |
| 1.3.6.1.4.1.4756.20.501.20.1.1838 | ColumnnidL2CPPort6DMAC0180C2000009RemoteA | read-write | current | NID Series card Port 6 L2CP Mode 0180C2000009 0: Forward 1: Discard 2: Peer |
| 1.3.6.1.4.1.4756.20.501.20.1.1839 | ColumnnidL2CPPort6DMAC0180C200000ARemoteA | read-write | current | NID Series card Port 6 L2CP Mode 0180C200000A 0: Forward 1: Discard 2: Peer |
| 1.3.6.1.4.1.4756.20.501.20.1.1840 | ColumnnidL2CPPort6DMAC0180C200000BRemoteA | read-write | current | NID Series card Port 6 L2CP Mode 0180C200000B 0: Forward 1: Discard 2: Peer |
| 1.3.6.1.4.1.4756.20.501.20.1.1841 | ColumnnidL2CPPort6DMAC0180C200000CRemoteA | read-write | current | NID Series card Port 6 L2CP Mode 0180C200000C 0: Forward 1: Discard 2: Peer |
| 1.3.6.1.4.1.4756.20.501.20.1.1842 | ColumnnidL2CPPort6DMAC0180C200000DRemoteA | read-write | current | NID Series card Port 6 L2CP Mode 0180C200000D 0: Forward 1: Discard 2: Peer |
| 1.3.6.1.4.1.4756.20.501.20.1.1843 | ColumnnidL2CPPort6DMAC0180C200000ERemoteA | read-write | current | NID Series card Port 6 L2CP Mode 0180C200000E 0: Forward 1: Discard 2: Peer |
| 1.3.6.1.4.1.4756.20.501.20.1.1844 | ColumnnidL2CPPort6DMAC0180C200000FRemoteA | read-write | current | NID Series card Port 6 L2CP Mode 0180C200000F 0: Forward 1: Discard 2: Peer |
| 1.3.6.1.4.1.4756.20.501.20.1.1845 | ColumnnidL2CPPort6DMAC0180C2000010RemoteA | read-write | current | NID Series card Port 6 L2CP Mode 0180C2000010 0: Forward 1: Discard 2: Peer |
| 1.3.6.1.4.1.4756.20.501.20.1.1846 | ColumnnidL2CPPort6DMAC0180C2000020RemoteA | read-write | current | NID Series card Port 6 L2CP Mode 0180C2000020 0: Forward 1: Discard 2: Peer |
| 1.3.6.1.4.1.4756.20.501.20.1.1847 | ColumnnidL2CPPort6DMAC0180C2000021RemoteA | read-write | current | NID Series card Port 6 L2CP Mode 0180C2000021 0: Forward 1: Discard 2: Peer |
| 1.3.6.1.4.1.4756.20.501.20.1.1848 | ColumnnidL2CPPort6DMAC0180C2000022RemoteA | read-write | current | NID Series card Port 6 L2CP Mode 0180C2000022 0: Forward 1: Discard 2: Peer |
| 1.3.6.1.4.1.4756.20.501.20.1.1849 | ColumnnidL2CPPort6DMAC0180C2000023RemoteA | read-write | current | NID Series card Port 6 L2CP Mode 0180C2000023 0: Forward 1: Discard 2: Peer |
| 1.3.6.1.4.1.4756.20.501.20.1.1850 | ColumnnidL2CPPort6DMAC0180C2000024RemoteA | read-write | current | NID Series card Port 6 L2CP Mode 0180C2000024 0: Forward 1: Discard 2: Peer |
| 1.3.6.1.4.1.4756.20.501.20.1.1851 | ColumnnidL2CPPort6DMAC0180C2000025RemoteA | read-write | current | NID Series card Port 6 L2CP Mode 0180C2000025 0: Forward 1: Discard 2: Peer |
| 1.3.6.1.4.1.4756.20.501.20.1.1852 | ColumnnidL2CPPort6DMAC0180C2000026RemoteA | read-write | current | NID Series card Port 6 L2CP Mode 0180C2000026 0: Forward 1: Discard 2: Peer |
| 1.3.6.1.4.1.4756.20.501.20.1.1853 | ColumnnidL2CPPort6DMAC0180C2000027RemoteA | read-write | current | NID Series card Port 6 L2CP Mode 0180C2000027 0: Forward 1: Discard 2: Peer |
| 1.3.6.1.4.1.4756.20.501.20.1.1854 | ColumnnidL2CPPort6DMAC0180C2000028RemoteA | read-write | current | NID Series card Port 6 L2CP Mode 0180C2000028 0: Forward 1: Discard 2: Peer |
| 1.3.6.1.4.1.4756.20.501.20.1.1855 | ColumnnidL2CPPort6DMAC0180C2000029RemoteA | read-write | current | NID Series card Port 6 L2CP Mode 0180C2000029 0: Forward 1: Discard 2: Peer |
| 1.3.6.1.4.1.4756.20.501.20.1.1856 | ColumnnidL2CPPort6DMAC0180C200002ARemoteA | read-write | current | NID Series card Port 6 L2CP Mode 0180C200002A 0: Forward 1: Discard 2: Peer |
| 1.3.6.1.4.1.4756.20.501.20.1.1857 | ColumnnidL2CPPort6DMAC0180C200002BRemoteA | read-write | current | NID Series card Port 6 L2CP Mode 0180C200002B 0: Forward 1: Discard 2: Peer |
| 1.3.6.1.4.1.4756.20.501.20.1.1858 | ColumnnidL2CPPort6DMAC0180C200002CRemoteA | read-write | current | NID Series card Port 6 L2CP Mode 0180C200002C 0: Forward 1: Discard 2: Peer |
| 1.3.6.1.4.1.4756.20.501.20.1.1859 | ColumnnidL2CPPort6DMAC0180C200002DRemoteA | read-write | current | NID Series card Port 6 L2CP Mode 0180C200002D 0: Forward 1: Discard 2: Peer |
| 1.3.6.1.4.1.4756.20.501.20.1.1860 | ColumnnidL2CPPort6DMAC0180C200002ERemoteA | read-write | current | NID Series card Port 6 L2CP Mode 0180C200002E 0: Forward 1: Discard 2: Peer |
| 1.3.6.1.4.1.4756.20.501.20.1.1861 | ColumnnidL2CPPort6DMAC0180C200002FRemoteA | read-write | current | NID Series card Port 6 L2CP Mode 0180C200002F 0: Forward 1: Discard 1: Peer |
| 1.3.6.1.4.1.4756.20.501.20.1.1862 | ColumnnidL2CPPort7DMAC0180C2000000RemoteA | read-write | current | NID Series card Port 7 L2CP Mode 0180C2000000 0: Forward 1: Discard 2: Peer |
| 1.3.6.1.4.1.4756.20.501.20.1.1863 | ColumnnidL2CPPort7DMAC0180C2000001RemoteA | read-write | current | NID Series card Port 7 L2CP Mode 0180C2000001 0: Forward 1: Discard 2: Peer |
| 1.3.6.1.4.1.4756.20.501.20.1.1864 | ColumnnidL2CPPort7DMAC0180C2000002RemoteA | read-write | current | NID Series card Port 7 L2CP Mode 0180C2000002 0: Forward 1: Discard 2: Peer |
| 1.3.6.1.4.1.4756.20.501.20.1.1865 | ColumnnidL2CPPort7DMAC0180C2000003RemoteA | read-write | current | NID Series card Port 7 L2CP Mode 0180C2000003 0: Forward 1: Discard 2: Peer |
| 1.3.6.1.4.1.4756.20.501.20.1.1866 | ColumnnidL2CPPort7DMAC0180C2000004RemoteA | read-write | current | NID Series card Port 7 L2CP Mode 0180C2000004 0: Forward 1: Discard 2: Peer |
| 1.3.6.1.4.1.4756.20.501.20.1.1867 | ColumnnidL2CPPort7DMAC0180C2000005RemoteA | read-write | current | NID Series card Port 7 L2CP Mode 0180C2000005 0: Forward 1: Discard 2: Peer |
| 1.3.6.1.4.1.4756.20.501.20.1.1868 | ColumnnidL2CPPort7DMAC0180C2000006RemoteA | read-write | current | NID Series card Port 7 L2CP Mode 0180C2000006 0: Forward 1: Discard 2: Peer |
| 1.3.6.1.4.1.4756.20.501.20.1.1869 | ColumnnidL2CPPort7DMAC0180C2000007RemoteA | read-write | current | NID Series card Port 7 L2CP Mode 0180C2000007 0: Forward 1: Discard 2: Peer |
| 1.3.6.1.4.1.4756.20.501.20.1.1870 | ColumnnidL2CPPort7DMAC0180C2000008RemoteA | read-write | current | NID Series card Port 7 L2CP Mode 0180C2000008 0: Forward 1: Discard 2: Peer |
| 1.3.6.1.4.1.4756.20.501.20.1.1871 | ColumnnidL2CPPort7DMAC0180C2000009RemoteA | read-write | current | NID Series card Port 7 L2CP Mode 0180C2000009 0: Forward 1: Discard 2: Peer |
| 1.3.6.1.4.1.4756.20.501.20.1.1872 | ColumnnidL2CPPort7DMAC0180C200000ARemoteA | read-write | current | NID Series card Port 7 L2CP Mode 0180C200000A 0: Forward 1: Discard 2: Peer |
| 1.3.6.1.4.1.4756.20.501.20.1.1873 | ColumnnidL2CPPort7DMAC0180C200000BRemoteA | read-write | current | NID Series card Port 7 L2CP Mode 0180C200000B 0: Forward 1: Discard 2: Peer |
| 1.3.6.1.4.1.4756.20.501.20.1.1874 | ColumnnidL2CPPort7DMAC0180C200000CRemoteA | read-write | current | NID Series card Port 7 L2CP Mode 0180C200000C 0: Forward 1: Discard 2: Peer |
| 1.3.6.1.4.1.4756.20.501.20.1.1875 | ColumnnidL2CPPort7DMAC0180C200000DRemoteA | read-write | current | NID Series card Port 7 L2CP Mode 0180C200000D 0: Forward 1: Discard 2: Peer |
| 1.3.6.1.4.1.4756.20.501.20.1.1876 | ColumnnidL2CPPort7DMAC0180C200000ERemoteA | read-write | current | NID Series card Port 7 L2CP Mode 0180C200000E 0: Forward 1: Discard 2: Peer |
| 1.3.6.1.4.1.4756.20.501.20.1.1877 | ColumnnidL2CPPort7DMAC0180C200000FRemoteA | read-write | current | NID Series card Port 7 L2CP Mode 0180C200000F 0: Forward 1: Discard 2: Peer |
| 1.3.6.1.4.1.4756.20.501.20.1.1878 | ColumnnidL2CPPort7DMAC0180C2000010RemoteA | read-write | current | NID Series card Port 7 L2CP Mode 0180C2000010 0: Forward 1: Discard 2: Peer |
| 1.3.6.1.4.1.4756.20.501.20.1.1879 | ColumnnidL2CPPort7DMAC0180C2000020RemoteA | read-write | current | NID Series card Port 7 L2CP Mode 0180C2000020 0: Forward 1: Discard 2: Peer |
| 1.3.6.1.4.1.4756.20.501.20.1.1880 | ColumnnidL2CPPort7DMAC0180C2000021RemoteA | read-write | current | NID Series card Port 7 L2CP Mode 0180C2000021 0: Forward 1: Discard 2: Peer |
| 1.3.6.1.4.1.4756.20.501.20.1.1881 | ColumnnidL2CPPort7DMAC0180C2000022RemoteA | read-write | current | NID Series card Port 7 L2CP Mode 0180C2000022 0: Forward 1: Discard 2: Peer |
| 1.3.6.1.4.1.4756.20.501.20.1.1882 | ColumnnidL2CPPort7DMAC0180C2000023RemoteA | read-write | current | NID Series card Port 7 L2CP Mode 0180C2000023 0: Forward 1: Discard 2: Peer |
| 1.3.6.1.4.1.4756.20.501.20.1.1883 | ColumnnidL2CPPort7DMAC0180C2000024RemoteA | read-write | current | NID Series card Port 7 L2CP Mode 0180C2000024 0: Forward 1: Discard 2: Peer |
| 1.3.6.1.4.1.4756.20.501.20.1.1884 | ColumnnidL2CPPort7DMAC0180C2000025RemoteA | read-write | current | NID Series card Port 7 L2CP Mode 0180C2000025 0: Forward 1: Discard 2: Peer |
| 1.3.6.1.4.1.4756.20.501.20.1.1885 | ColumnnidL2CPPort7DMAC0180C2000026RemoteA | read-write | current | NID Series card Port 7 L2CP Mode 0180C2000026 0: Forward 1: Discard 2: Peer |
| 1.3.6.1.4.1.4756.20.501.20.1.1886 | ColumnnidL2CPPort7DMAC0180C2000027RemoteA | read-write | current | NID Series card Port 7 L2CP Mode 0180C2000027 0: Forward 1: Discard 2: Peer |
| 1.3.6.1.4.1.4756.20.501.20.1.1887 | ColumnnidL2CPPort7DMAC0180C2000028RemoteA | read-write | current | NID Series card Port 7 L2CP Mode 0180C2000028 0: Forward 1: Discard 2: Peer |
| 1.3.6.1.4.1.4756.20.501.20.1.1888 | ColumnnidL2CPPort7DMAC0180C2000029RemoteA | read-write | current | NID Series card Port 7 L2CP Mode 0180C2000029 0: Forward 1: Discard 2: Peer |
| 1.3.6.1.4.1.4756.20.501.20.1.1889 | ColumnnidL2CPPort7DMAC0180C200002ARemoteA | read-write | current | NID Series card Port 7 L2CP Mode 0180C200002A 0: Forward 1: Discard 2: Peer |
| 1.3.6.1.4.1.4756.20.501.20.1.1890 | ColumnnidL2CPPort7DMAC0180C200002BRemoteA | read-write | current | NID Series card Port 7 L2CP Mode 0180C200002B 0: Forward 1: Discard 2: Peer |
| 1.3.6.1.4.1.4756.20.501.20.1.1891 | ColumnnidL2CPPort7DMAC0180C200002CRemoteA | read-write | current | NID Series card Port 7 L2CP Mode 0180C200002C 0: Forward 1: Discard 2: Peer |
| 1.3.6.1.4.1.4756.20.501.20.1.1892 | ColumnnidL2CPPort7DMAC0180C200002DRemoteA | read-write | current | NID Series card Port 7 L2CP Mode 0180C200002D 0: Forward 1: Discard 2: Peer |
| 1.3.6.1.4.1.4756.20.501.20.1.1893 | ColumnnidL2CPPort7DMAC0180C200002ERemoteA | read-write | current | NID Series card Port 7 L2CP Mode 0180C200002E 0: Forward 1: Discard 2: Peer |
| 1.3.6.1.4.1.4756.20.501.20.1.1894 | ColumnnidL2CPPort7DMAC0180C200002FRemoteA | read-write | current | NID Series card Port 7 L2CP Mode 0180C200002F 0: Forward 1: Discard 1: Peer |
| 1.3.6.1.4.1.4756.20.501.20.1.1895 | ColumnnidL2CPPort8DMAC0180C2000000RemoteA | read-write | current | NID Series card Port 8 L2CP Mode 0180C2000000 0: Forward 1: Discard 2: Peer |
| 1.3.6.1.4.1.4756.20.501.20.1.1896 | ColumnnidL2CPPort8DMAC0180C2000001RemoteA | read-write | current | NID Series card Port 8 L2CP Mode 0180C2000001 0: Forward 1: Discard 2: Peer |
| 1.3.6.1.4.1.4756.20.501.20.1.1897 | ColumnnidL2CPPort8DMAC0180C2000002RemoteA | read-write | current | NID Series card Port 8 L2CP Mode 0180C2000002 0: Forward 1: Discard 2: Peer |
| 1.3.6.1.4.1.4756.20.501.20.1.1898 | ColumnnidL2CPPort8DMAC0180C2000003RemoteA | read-write | current | NID Series card Port 8 L2CP Mode 0180C2000003 0: Forward 1: Discard 2: Peer |
| 1.3.6.1.4.1.4756.20.501.20.1.1899 | ColumnnidL2CPPort8DMAC0180C2000004RemoteA | read-write | current | NID Series card Port 8 L2CP Mode 0180C2000004 0: Forward 1: Discard 2: Peer |
| 1.3.6.1.4.1.4756.20.501.20.1.1900 | ColumnnidL2CPPort8DMAC0180C2000005RemoteA | read-write | current | NID Series card Port 8 L2CP Mode 0180C2000005 0: Forward 1: Discard 2: Peer |
| 1.3.6.1.4.1.4756.20.501.20.1.1901 | ColumnnidL2CPPort8DMAC0180C2000006RemoteA | read-write | current | NID Series card Port 8 L2CP Mode 0180C2000006 0: Forward 1: Discard 2: Peer |
| 1.3.6.1.4.1.4756.20.501.20.1.1902 | ColumnnidL2CPPort8DMAC0180C2000007RemoteA | read-write | current | NID Series card Port 8 L2CP Mode 0180C2000007 0: Forward 1: Discard 2: Peer |
| 1.3.6.1.4.1.4756.20.501.20.1.1903 | ColumnnidL2CPPort8DMAC0180C2000008RemoteA | read-write | current | NID Series card Port 8 L2CP Mode 0180C2000008 0: Forward 1: Discard 2: Peer |
| 1.3.6.1.4.1.4756.20.501.20.1.1904 | ColumnnidL2CPPort8DMAC0180C2000009RemoteA | read-write | current | NID Series card Port 8 L2CP Mode 0180C2000009 0: Forward 1: Discard 2: Peer |
| 1.3.6.1.4.1.4756.20.501.20.1.1905 | ColumnnidL2CPPort8DMAC0180C200000ARemoteA | read-write | current | NID Series card Port 8 L2CP Mode 0180C200000A 0: Forward 1: Discard 2: Peer |
| 1.3.6.1.4.1.4756.20.501.20.1.1906 | ColumnnidL2CPPort8DMAC0180C200000BRemoteA | read-write | current | NID Series card Port 8 L2CP Mode 0180C200000B 0: Forward 1: Discard 2: Peer |
| 1.3.6.1.4.1.4756.20.501.20.1.1907 | ColumnnidL2CPPort8DMAC0180C200000CRemoteA | read-write | current | NID Series card Port 8 L2CP Mode 0180C200000C 0: Forward 1: Discard 2: Peer |
| 1.3.6.1.4.1.4756.20.501.20.1.1908 | ColumnnidL2CPPort8DMAC0180C200000DRemoteA | read-write | current | NID Series card Port 8 L2CP Mode 0180C200000D 0: Forward 1: Discard 2: Peer |
| 1.3.6.1.4.1.4756.20.501.20.1.1909 | ColumnnidL2CPPort8DMAC0180C200000ERemoteA | read-write | current | NID Series card Port 8 L2CP Mode 0180C200000E 0: Forward 1: Discard 2: Peer |
| 1.3.6.1.4.1.4756.20.501.20.1.1910 | ColumnnidL2CPPort8DMAC0180C200000FRemoteA | read-write | current | NID Series card Port 8 L2CP Mode 0180C200000F 0: Forward 1: Discard 2: Peer |
| 1.3.6.1.4.1.4756.20.501.20.1.1911 | ColumnnidL2CPPort8DMAC0180C2000010RemoteA | read-write | current | NID Series card Port 8 L2CP Mode 0180C2000010 0: Forward 1: Discard 2: Peer |
| 1.3.6.1.4.1.4756.20.501.20.1.1912 | ColumnnidL2CPPort8DMAC0180C2000020RemoteA | read-write | current | NID Series card Port 8 L2CP Mode 0180C2000020 0: Forward 1: Discard 2: Peer |
| 1.3.6.1.4.1.4756.20.501.20.1.1913 | ColumnnidL2CPPort8DMAC0180C2000021RemoteA | read-write | current | NID Series card Port 8 L2CP Mode 0180C2000021 0: Forward 1: Discard 2: Peer |
| 1.3.6.1.4.1.4756.20.501.20.1.1914 | ColumnnidL2CPPort8DMAC0180C2000022RemoteA | read-write | current | NID Series card Port 8 L2CP Mode 0180C2000022 0: Forward 1: Discard 2: Peer |
| 1.3.6.1.4.1.4756.20.501.20.1.1915 | ColumnnidL2CPPort8DMAC0180C2000023RemoteA | read-write | current | NID Series card Port 8 L2CP Mode 0180C2000023 0: Forward 1: Discard 2: Peer |
| 1.3.6.1.4.1.4756.20.501.20.1.1916 | ColumnnidL2CPPort8DMAC0180C2000024RemoteA | read-write | current | NID Series card Port 8 L2CP Mode 0180C2000024 0: Forward 1: Discard 2: Peer |
| 1.3.6.1.4.1.4756.20.501.20.1.1917 | ColumnnidL2CPPort8DMAC0180C2000025RemoteA | read-write | current | NID Series card Port 8 L2CP Mode 0180C2000025 0: Forward 1: Discard 2: Peer |
| 1.3.6.1.4.1.4756.20.501.20.1.1918 | ColumnnidL2CPPort8DMAC0180C2000026RemoteA | read-write | current | NID Series card Port 8 L2CP Mode 0180C2000026 0: Forward 1: Discard 2: Peer |
| 1.3.6.1.4.1.4756.20.501.20.1.1919 | ColumnnidL2CPPort8DMAC0180C2000027RemoteA | read-write | current | NID Series card Port 8 L2CP Mode 0180C2000027 0: Forward 1: Discard 2: Peer |
| 1.3.6.1.4.1.4756.20.501.20.1.1920 | ColumnnidL2CPPort8DMAC0180C2000028RemoteA | read-write | current | NID Series card Port 8 L2CP Mode 0180C2000028 0: Forward 1: Discard 2: Peer |
| 1.3.6.1.4.1.4756.20.501.20.1.1921 | ColumnnidL2CPPort8DMAC0180C2000029RemoteA | read-write | current | NID Series card Port 8 L2CP Mode 0180C2000029 0: Forward 1: Discard 2: Peer |
| 1.3.6.1.4.1.4756.20.501.20.1.1922 | ColumnnidL2CPPort8DMAC0180C200002ARemoteA | read-write | current | NID Series card Port 8 L2CP Mode 0180C200002A 0: Forward 1: Discard 2: Peer |
| 1.3.6.1.4.1.4756.20.501.20.1.1923 | ColumnnidL2CPPort8DMAC0180C200002BRemoteA | read-write | current | NID Series card Port 8 L2CP Mode 0180C200002B 0: Forward 1: Discard 2: Peer |
| 1.3.6.1.4.1.4756.20.501.20.1.1924 | ColumnnidL2CPPort8DMAC0180C200002CRemoteA | read-write | current | NID Series card Port 8 L2CP Mode 0180C200002C 0: Forward 1: Discard 2: Peer |
| 1.3.6.1.4.1.4756.20.501.20.1.1925 | ColumnnidL2CPPort8DMAC0180C200002DRemoteA | read-write | current | NID Series card Port 8 L2CP Mode 0180C200002D 0: Forward 1: Discard 2: Peer |
| 1.3.6.1.4.1.4756.20.501.20.1.1926 | ColumnnidL2CPPort8DMAC0180C200002ERemoteA | read-write | current | NID Series card Port 8 L2CP Mode 0180C200002E 0: Forward 1: Discard 2: Peer |
| 1.3.6.1.4.1.4756.20.501.20.1.1927 | ColumnnidL2CPPort8DMAC0180C200002FRemoteA | read-write | current | NID Series card Port 8 L2CP Mode 0180C200002F 0: Forward 1: Discard 1: Peer |
| 1.3.6.1.4.1.4756.20.501.20.1.1928 | ColumnnidFx1DDRemoteA | read-only | current | NID Series card fiber port Digital Diagnostic function: 0:No 1:Yes |
| 1.3.6.1.4.1.4756.20.501.20.1.1929 | ColumnnidFx1DDVendorRemoteA | read-only | current | NID Series card fiber port D/D information: Vendor name |
| 1.3.6.1.4.1.4756.20.501.20.1.1930 | ColumnnidFx1DDPartNoRemoteA | read-only | current | NID Series card fiber port D/D information: Vendor part number |
| 1.3.6.1.4.1.4756.20.501.20.1.1931 | ColumnnidFx1DDFiberTypeRemoteA | read-only | current | NID Series card fiber port D/D information: Fiber Type |
| 1.3.6.1.4.1.4756.20.501.20.1.1932 | ColumnnidFx1DDWaveLenRemoteA | read-only | current | NID Series card fiber port D/D information: Wave length |
| 1.3.6.1.4.1.4756.20.501.20.1.1933 | ColumnnidFx1DDWaveLen2RemoteA | read-only | current | NID Series card fiber port D/D information: Wave length 2 |
| 1.3.6.1.4.1.4756.20.501.20.1.1934 | ColumnnidFx1DDLinkLenRemoteA | read-only | current | NID Series card fiber port D/D information: Link length |
| 1.3.6.1.4.1.4756.20.501.20.1.1935 | ColumnnidFx1DDLenUnitRemoteA | read-only | current | NID Series card fiber port D/D information: Length Unit |
| 1.3.6.1.4.1.4756.20.501.20.1.1936 | ColumnnidFx1DDStatusRemoteA | read-only | current | NID Series card fiber port D/D information: Status Support |
| 1.3.6.1.4.1.4756.20.501.20.1.1937 | ColumnnidFx1DDRxSensRemoteA | read-only | current | NID Series card fiber port D/D information: Rx Sensitivity |
| 1.3.6.1.4.1.4756.20.501.20.1.1938 | ColumnnidFx1DDTxPWRRemoteA | read-only | current | NID Series card fiber port D/D information: Tx power |
| 1.3.6.1.4.1.4756.20.501.20.1.1939 | ColumnnidFx1DDRxPWRRemoteA | read-only | current | NID Series card fiber port D/D information: Rx power |
| 1.3.6.1.4.1.4756.20.501.20.1.1940 | ColumnnidFx1DDTempRemoteA | read-only | current | NID Series card fiber port D/D information: Temperature in degree C |
| 1.3.6.1.4.1.4756.20.501.20.1.1941 | ColumnnidFx1DDPWRMarginRemoteA | read-only | current | NID Series card fiber port D/D information: Power margin |
| 1.3.6.1.4.1.4756.20.501.20.1.1942 | ColumnnidFx1DDPWRLossRemoteA | read-only | current | NID Series card fiber port D/D information: Power loss |
| 1.3.6.1.4.1.4756.20.501.20.1.1943 | ColumnnidFx2DDRemoteA | read-only | current | NID Series card fiber2 Digital Diagnostic function: 0:NO 1:Yes |
| 1.3.6.1.4.1.4756.20.501.20.1.1944 | ColumnnidFx2DDVendorRemoteA | read-only | current | NID Series card fiber2 D/D information: Vendor name |
| 1.3.6.1.4.1.4756.20.501.20.1.1945 | ColumnnidFx2DDPartNoRemoteA | read-only | current | NID Series card fiber2 D/D information: Vendor part number |
| 1.3.6.1.4.1.4756.20.501.20.1.1946 | ColumnnidFx2DDFiberTypeRemoteA | read-only | current | NID Series card fiber2 D/D information: Fiber Type |
| 1.3.6.1.4.1.4756.20.501.20.1.1947 | ColumnnidFx2DDWaveLenRemoteA | read-only | current | NID Series card fiber2 D/D information: Wave length 1 |
| 1.3.6.1.4.1.4756.20.501.20.1.1948 | ColumnnidFx2DDWaveLen2RemoteA | read-only | current | NID Series card fiber2 D/D information: Wave length 2 |
| 1.3.6.1.4.1.4756.20.501.20.1.1949 | ColumnnidFx2DDLinkLenRemoteA | read-only | current | NID Series card fiber2 D/D information: Link length |
| 1.3.6.1.4.1.4756.20.501.20.1.1950 | ColumnnidFx2DDLenUnitRemoteA | read-only | current | NID Series card fiber2 D/D information: Length Unit |
| 1.3.6.1.4.1.4756.20.501.20.1.1951 | ColumnnidFx2DDStatusRemoteA | read-only | current | NID Series card fiber2 D/D information: Status Support |
| 1.3.6.1.4.1.4756.20.501.20.1.1952 | ColumnnidFx2DDRxSensRemoteA | read-only | current | NID Series card fiber2 D/D information: Rx Sensitivity |
| 1.3.6.1.4.1.4756.20.501.20.1.1953 | ColumnnidFx2DDTxPWRRemoteA | read-only | current | NID Series card fiber2 D/D information: Tx power |
| 1.3.6.1.4.1.4756.20.501.20.1.1954 | ColumnnidFx2DDRxPWRRemoteA | read-only | current | NID Series card fiber2 D/D information: Rx power |
| 1.3.6.1.4.1.4756.20.501.20.1.1955 | ColumnnidFx2DDTempRemoteA | read-only | current | NID Series card fiber2 D/D information: Temperature in degree C |
| 1.3.6.1.4.1.4756.20.501.20.1.1956 | ColumnnidFx2DDPWRMarginRemoteA | read-only | current | NID Series card fiber2 D/D information: Power margin |
| 1.3.6.1.4.1.4756.20.501.20.1.1957 | ColumnnidFx2DDPWRLossRemoteA | read-only | current | NID Series card fiber2 D/D information: Power loss |
| 1.3.6.1.4.1.4756.20.501.20.1.1958 | ColumnnidFx3DDRemoteA | read-only | current | NID Series card fiber3 Digital Diagnostic function: 0:NO 1:Yes |
| 1.3.6.1.4.1.4756.20.501.20.1.1959 | ColumnnidFx3DDVendorRemoteA | read-only | current | NID Series card fiber3 D/D information: Vendor name |
| 1.3.6.1.4.1.4756.20.501.20.1.1960 | ColumnnidFx3DDPartNoRemoteA | read-only | current | NID Series card fiber32 D/D information: Vendor part number |
| 1.3.6.1.4.1.4756.20.501.20.1.1961 | ColumnnidFx3DDFiberTypeRemoteA | read-only | current | NID Series card fiber3 D/D information: Fiber Type |
| 1.3.6.1.4.1.4756.20.501.20.1.1962 | ColumnnidFx3DDWaveLenRemoteA | read-only | current | NID Series card fiber3 D/D information: Wave length 1 |
| 1.3.6.1.4.1.4756.20.501.20.1.1963 | ColumnnidFx3DDWaveLen2RemoteA | read-only | current | NID Series card fiber3 D/D information: Wave length 2 |
| 1.3.6.1.4.1.4756.20.501.20.1.1964 | ColumnnidFx3DDLinkLenRemoteA | read-only | current | NID Series card fiber3 D/D information: Link length |
| 1.3.6.1.4.1.4756.20.501.20.1.1965 | ColumnnidFx3DDLenUnitRemoteA | read-only | current | NID Series card fiber3 D/D information: Length Unit |
| 1.3.6.1.4.1.4756.20.501.20.1.1966 | ColumnnidFx3DDStatusRemoteA | read-only | current | NID Series card fiber3 D/D information: Status Support |
| 1.3.6.1.4.1.4756.20.501.20.1.1967 | ColumnnidFx3DDRxSensRemoteA | read-only | current | NID Series card fiber3 D/D information: Rx Sensitivity |
| 1.3.6.1.4.1.4756.20.501.20.1.1968 | ColumnnidFx3DDTxPWRRemoteA | read-only | current | NID Series card fiber3 D/D information: Tx power |
| 1.3.6.1.4.1.4756.20.501.20.1.1969 | ColumnnidFx3DDRxPWRRemoteA | read-only | current | NID Series card fiber3 D/D information: Rx power |
| 1.3.6.1.4.1.4756.20.501.20.1.1970 | ColumnnidFx3DDTempRemoteA | read-only | current | NID Series card fiber3 D/D information: Temperature in degree C |
| 1.3.6.1.4.1.4756.20.501.20.1.1971 | ColumnnidFx3DDPWRMarginRemoteA | read-only | current | NID Series card fiber3 D/D information: Power margin |
| 1.3.6.1.4.1.4756.20.501.20.1.1972 | ColumnnidFx3DDPWRLossRemoteA | read-only | current | NID Series card fiber3 D/D information: Power loss |
| 1.3.6.1.4.1.4756.20.501.20.1.1973 | ColumnnidFx4DDRemoteA | read-only | current | NID Series card fiber4 Digital Diagnostic function: 0:NO 1:Yes |
| 1.3.6.1.4.1.4756.20.501.20.1.1974 | ColumnnidFx4DDVendorRemoteA | read-only | current | NID Series card fiber4 D/D information: Vendor name |
| 1.3.6.1.4.1.4756.20.501.20.1.1975 | ColumnnidFx4DDPartNoRemoteA | read-only | current | NID Series card fiber4 D/D information: Vendor part number |
| 1.3.6.1.4.1.4756.20.501.20.1.1976 | ColumnnidFx4DDFiberTypeRemoteA | read-only | current | NID Series card fiber4 D/D information: Fiber Type |
| 1.3.6.1.4.1.4756.20.501.20.1.1977 | ColumnnidFx4DDWaveLenRemoteA | read-only | current | NID Series card fiber4 D/D information: Wave length 1 |
| 1.3.6.1.4.1.4756.20.501.20.1.1978 | ColumnnidFx4DDWaveLen2RemoteA | read-only | current | NID Series card fiber4 D/D information: Wave length 2 |
| 1.3.6.1.4.1.4756.20.501.20.1.1979 | ColumnnidFx4DDLinkLenRemoteA | read-only | current | NID Series card fiber4 D/D information: Link length |
| 1.3.6.1.4.1.4756.20.501.20.1.1980 | ColumnnidFx4DDLenUnitRemoteA | read-only | current | NID Series card fiber4 D/D information: Length Unit |
| 1.3.6.1.4.1.4756.20.501.20.1.1981 | ColumnnidFx4DDStatusRemoteA | read-only | current | NID Series card fiber4 D/D information: Status Support |
| 1.3.6.1.4.1.4756.20.501.20.1.1982 | ColumnnidFx4DDRxSensRemoteA | read-only | current | NID Series card fiber4 D/D information: Rx Sensitivity |
| 1.3.6.1.4.1.4756.20.501.20.1.1983 | ColumnnidFx4DDTxPWRRemoteA | read-only | current | NID Series card fiber4 D/D information: Tx power |
| 1.3.6.1.4.1.4756.20.501.20.1.1984 | ColumnnidFx4DDRxPWRRemoteA | read-only | current | NID Series card fiber4 D/D information: Rx power |
| 1.3.6.1.4.1.4756.20.501.20.1.1985 | ColumnnidFx4DDTempRemoteA | read-only | current | NID Series card fiber4 D/D information: Temperature in degree C |
| 1.3.6.1.4.1.4756.20.501.20.1.1986 | ColumnnidFx4DDPWRMarginRemoteA | read-only | current | NID Series card fiber4 D/D information: Power margin |
| 1.3.6.1.4.1.4756.20.501.20.1.1987 | ColumnnidFx4DDPWRLossRemoteA | read-only | current | NID Series card fiber4 D/D information: Power loss |
| 1.3.6.1.4.1.4756.20.501.20.1.1988 | ColumnnidDeviceActiveRemoteA | read-write | current | NID Series card u-Ring device active 0: Disable 1: Enable |
| 1.3.6.1.4.1.4756.20.501.20.1.1989 | ColumnnidSaveStartupCongRemoteA | read-write | current | NID Series card save start-up config 0: OFF 1: Action |
| 1.3.6.1.4.1.4756.20.501.20.1.1990 | ColumnnidPortResetRemoteA | read-write | current | NID Series card port reset 0: OFF 1: Action |
| 1.3.6.1.4.1.4756.20.501.20.1.1991 | ColumnnidSetDefaultRemoteA | read-write | current | NID Series card set to default config 0: OFF 1: Action |
| 1.3.6.1.4.1.4756.20.501.20.1.1992 | ColumnnidSetDefault2RemoteA | read-write | current | NID Series card set to default config (Without OAM) 0: OFF 1: Action |
| 1.3.6.1.4.1.4756.20.501.20.1.1993 | ColumnnidClearPortCounterRemoteA | read-write | current | NID Series card clear port counter: 0: Off 1: Action |
| 1.3.6.1.4.1.4756.20.501.20.1.1994 | ColumnnidClearOAMCounterRemoteA | read-write | current | NID Series card Clear OAM Counter: 0: Off 1: Action |
| 1.3.6.1.4.1.4756.20.501.20.1.1995 | ColumnnidSTPStatisticsPortClearCounterRemoteA | read-write | current | NID Series card STP Port Statistics: Clear Counters 0: OFff 1: Action |
| 1.3.6.1.4.1.4756.20.501.20.1.1996 | ColumnnidAlarmRemoteA | read-only | current | NID Series card Alarm led status: 0: Off 1: On |
| 1.3.6.1.4.1.4756.20.501.20.1.1997 | ColumnnidTest1RemoteA | read-only | current | NID Series card Test1 led status: 0: Off 1: On |
| 1.3.6.1.4.1.4756.20.501.20.1.1998 | ColumnnidTest2RemoteA | read-only | current | NID Series card Test2 led status: 0: Off 1: On |
| 1.3.6.1.4.1.4756.20.502 | NodenidRemoteBCards | |||
| 1.3.6.1.4.1.4756.20.502.20 | TablenidRemoteBTable | not-accessible | current | A list of RemoteB FRM220-MSW404/MSW404S card entries. The number of entries is f16G3R-No-L. |
| 1.3.6.1.4.1.4756.20.502.20.1 | RownidRemoteBEntry | not-accessible | current | An entry containing management information applicable to a particular RemoteB FRM220-MSW404/MSW404S card. |
| 1.3.6.1.4.1.4756.20.502.20.1.1 | ColumnnidChassisIndexRemoteB | read-only | current | A unique value for each RemoteB card. It is the chassis location number. |
| 1.3.6.1.4.1.4756.20.502.20.1.2 | ColumnnidSlotIndexRemoteB | read-only | current | A unique value for each RemoteB card. It is the slot location number. |
| 1.3.6.1.4.1.4756.20.502.20.1.3 | ColumnnidCardHWVerRemoteB | read-only | current | RemoteB NID card hardware version x.xxx |
| 1.3.6.1.4.1.4756.20.502.20.1.4 | ColumnnidCardFWVerRemoteB | read-only | current | RemoteB NID card firmware version x.xxx |
| 1.3.6.1.4.1.4756.20.502.20.1.5 | ColumnnidCardCPLDVerRemoteB | read-only | current | RemoteB NID card CPLD version x.xxx |
| 1.3.6.1.4.1.4756.20.502.20.1.6 | ColumnnidCardFPGAVerRemoteB | read-only | current | RemoteB NID card FPGA version x.xxx |
| 1.3.6.1.4.1.4756.20.502.20.1.7 | ColumnnidModelRemoteB | read-only | current | Card Type: 0:MSW404 1:MSW404S |
| 1.3.6.1.4.1.4756.20.502.20.1.8 | ColumnnidDNSServerTypeRemoteB | read-write | current | NID Series card IP Configuration: This setting controls the DNS name resolution done by the switch. The following modes are supported: 1:From any DHCP interfac… |
| 1.3.6.1.4.1.4756.20.502.20.1.9 | ColumnnidDNSServerSettingRemoteB | read-write | current | NID Series card IP Configuration: If iDNSServerType setting '3:Configured',this value must setting IP address format as below: Dotted Decimal Notation refers t… |
| 1.3.6.1.4.1.4756.20.502.20.1.10 | ColumnnidDNSproxyRemoteB | read-write | current | NID Series card IP Configuration: When DNS proxy is enabled, system will relay DNS requests to the currently configured DNS server, and reply as a DNS resolver… |
| 1.3.6.1.4.1.4756.20.502.20.1.11 | ColumnnidAddIPV4InterfaceRemoteB | read-write | current | NID Series card IP Interfaces: Add a new IP VLAN Interface: Syntax: [<Interface>] [<vlan_list>] [<IPV4_Addr>] [<IPV4_MASK>] Interface : 1~4 |
| 1.3.6.1.4.1.4756.20.502.20.1.12 | ColumnnidDeleteInterfaceRemoteB | read-write | current | NID Series card IP Interfaces: Delete a IPv4/v6 VLAN Interface: Syntax: [<Interface>] Interface: 1~4 |
| 1.3.6.1.4.1.4756.20.502.20.1.13 | ColumnnidIPInterface1VLANRemoteB | read-only | current | NID Series card IP Interfaces: The VLAN associated with the IP interface. Only ports in this VLAN will be able to access the IP interface. This field is only a… |
| 1.3.6.1.4.1.4756.20.502.20.1.14 | ColumnnidIPInterface1DHCPRemoteB | read-write | current | NID Series card IP Interfaces: DHCP |
| 1.3.6.1.4.1.4756.20.502.20.1.15 | ColumnnidIPInterface1FallbackRemoteB | read-write | current | NID Series card IP Interfaces: Fallback |
| 1.3.6.1.4.1.4756.20.502.20.1.16 | ColumnnidIPInterface1IPV4AddressRemoteB | read-only | current | NID Series card IP Interfaces: IPV4 Address |
| 1.3.6.1.4.1.4756.20.502.20.1.17 | ColumnnidIPInterface1IPV4MASKLenRemoteB | read-only | current | NID Series card IP Interfaces: IPV4 MASK Length |
| 1.3.6.1.4.1.4756.20.502.20.1.18 | ColumnnidIPInterface2VLANRemoteB | read-only | current | NID Series card IP Interfaces: The VLAN associated with the IP interface. Only ports in this VLAN will be able to access the IP interface. This field is only a… |
| 1.3.6.1.4.1.4756.20.502.20.1.19 | ColumnnidIPInterface2DHCPRemoteB | read-write | current | NID Series card IP Interfaces: DHCP |
| 1.3.6.1.4.1.4756.20.502.20.1.20 | ColumnnidIPInterface2FallbackRemoteB | read-write | current | NID Series card IP Interfaces: Fallback |
| 1.3.6.1.4.1.4756.20.502.20.1.21 | ColumnnidIPInterface2IPV4AddressRemoteB | read-only | current | NID Series card IP Interfaces: IPV4 Address |
| 1.3.6.1.4.1.4756.20.502.20.1.22 | ColumnnidIPInterface2IPV4MASKLenRemoteB | read-only | current | NID Series card IP Interfaces: IPV4 MASK Length |
| 1.3.6.1.4.1.4756.20.502.20.1.23 | ColumnnidIPInterface3VLANRemoteB | read-only | current | NID Series card IP Interfaces: The VLAN associated with the IP interface. Only ports in this VLAN will be able to access the IP interface. This field is only a… |
| 1.3.6.1.4.1.4756.20.502.20.1.24 | ColumnnidIPInterface3DHCPRemoteB | read-write | current | NID Series card IP Interfaces: DHCP |
| 1.3.6.1.4.1.4756.20.502.20.1.25 | ColumnnidIPInterface3FallbackRemoteB | read-write | current | NID Series card IP Interfaces: Fallback |
| 1.3.6.1.4.1.4756.20.502.20.1.26 | ColumnnidIPInterface3IPV4AddressRemoteB | read-only | current | NID Series card IP Interfaces: IPV4 Address |
| 1.3.6.1.4.1.4756.20.502.20.1.27 | ColumnnidIPInterface3IPV4MASKLenRemoteB | read-only | current | NID Series card IP Interfaces: IPV4 MASK Length |
| 1.3.6.1.4.1.4756.20.502.20.1.28 | ColumnnidIPInterface4VLANRemoteB | read-only | current | NID Series card IP Interfaces: The VLAN associated with the IP interface. Only ports in this VLAN will be able to access the IP interface. This field is only a… |
| 1.3.6.1.4.1.4756.20.502.20.1.29 | ColumnnidIPInterface4DHCPRemoteB | read-write | current | NID Series card IP Interfaces: DHCP |
| 1.3.6.1.4.1.4756.20.502.20.1.30 | ColumnnidIPInterface4FallbackRemoteB | read-write | current | NID Series card IP Interfaces: Fallback |
| 1.3.6.1.4.1.4756.20.502.20.1.31 | ColumnnidIPInterface4IPV4AddressRemoteB | read-only | current | NID Series card IP Interfaces: IPV4 Address |
| 1.3.6.1.4.1.4756.20.502.20.1.32 | ColumnnidIPInterface4IPV4MASKLenRemoteB | read-only | current | NID Series card IP Interfaces: IPV4 MASK Length |
| 1.3.6.1.4.1.4756.20.502.20.1.33 | ColumnnidAddIPV6InterfaceRemoteB | read-write | current | NID Series card IP Interfaces: Add a new IPv6 VLAN Interface: Syntax: [<Interface>] [<vlan_list>] [<IPV4_Addr>] [<IPV4_MASK>] Interface : 1~4 |
| 1.3.6.1.4.1.4756.20.502.20.1.34 | ColumnnidIPInterface1IPV6AddressRemoteB | read-only | current | NID Series card IP Interfaces: IPV6 Address |
| 1.3.6.1.4.1.4756.20.502.20.1.35 | ColumnnidIPInterface1IPV6MASKLenRemoteB | read-only | current | NID Series card IP Interfaces: IPV6 MASK Length |
| 1.3.6.1.4.1.4756.20.502.20.1.36 | ColumnnidIPInterface2IPV6AddressRemoteB | read-only | current | NID Series card IP Interfaces: IPV6 Address |
| 1.3.6.1.4.1.4756.20.502.20.1.37 | ColumnnidIPInterface2IPV6MASKLenRemoteB | read-only | current | NID Series card IP Interfaces: IPV6 MASK Length |
| 1.3.6.1.4.1.4756.20.502.20.1.38 | ColumnnidIPInterface3IPV6AddressRemoteB | read-only | current | NID Series card IP Interfaces: IPV6 Address |
| 1.3.6.1.4.1.4756.20.502.20.1.39 | ColumnnidIPInterface3IPV6MASKLenRemoteB | read-only | current | NID Series card IP Interfaces: IPV6 MASK Length |
| 1.3.6.1.4.1.4756.20.502.20.1.40 | ColumnnidIPInterface4IPV6AddressRemoteB | read-only | current | NID Series card IP Interfaces: IPV6 Address |
| 1.3.6.1.4.1.4756.20.502.20.1.41 | ColumnnidIPInterface4IPV6MASKLenRemoteB | read-only | current | NID Series card IP Interfaces: IPV6 MASK Length |
| 1.3.6.1.4.1.4756.20.502.20.1.42 | ColumnnidPort1LinkstsRemoteB | read-only | current | NID Series card Port1 link status: 0:Link down 1:Link up |
| 1.3.6.1.4.1.4756.20.502.20.1.43 | ColumnnidPort1SpeedstsRemoteB | read-only | current | NID Series card Port1 speed status 10Base-T 100Base-Tx 1000Base-Tx 2.5G |
| 1.3.6.1.4.1.4756.20.502.20.1.44 | ColumnnidPort1DuplexstsRemoteB | read-only | current | NID Series card Port1 duplex status 0: Half 1: Full |
| 1.3.6.1.4.1.4756.20.502.20.1.45 | ColumnnidPort1RxPausestsRemoteB | read-only | current | NID Series card Port1 rx pause status 0: No 1: Yes |
| 1.3.6.1.4.1.4756.20.502.20.1.46 | ColumnnidPort1TxPausestsRemoteB | read-only | current | NID Series card Port1 tx pause status 0: No 1: Yes |
| 1.3.6.1.4.1.4756.20.502.20.1.47 | ColumnnidPort2LinkstsRemoteB | read-only | current | NID Series card Port2 link status: 0:Link down 1:Link up |
| 1.3.6.1.4.1.4756.20.502.20.1.48 | ColumnnidPort2SpeedstsRemoteB | read-only | current | NID Series card Port2 speed status 10Base-T 100Base-Tx 1000Base-Tx 2.5G |
| 1.3.6.1.4.1.4756.20.502.20.1.49 | ColumnnidPort2DuplexstsRemoteB | read-only | current | NID Series card Port2 duplex status 0: Half 1: Full |
| 1.3.6.1.4.1.4756.20.502.20.1.50 | ColumnnidPort2RxPausestsRemoteB | read-only | current | NID Series card Port2 rx pause status 0: No 1: Yes |
| 1.3.6.1.4.1.4756.20.502.20.1.51 | ColumnnidPort2TxPausestsRemoteB | read-only | current | NID Series card Port2 tx pause status 0: No 1: Yes |
| 1.3.6.1.4.1.4756.20.502.20.1.52 | ColumnnidPort3LinkstsRemoteB | read-only | current | NID Series card Port3 link status: 0:Link down 1:Link up |
| 1.3.6.1.4.1.4756.20.502.20.1.53 | ColumnnidPort3SpeedstsRemoteB | read-only | current | NID Series card Port3 speed status 10Base-T 100Base-Tx 1000Base-Tx |
| 1.3.6.1.4.1.4756.20.502.20.1.54 | ColumnnidPort3DuplexstsRemoteB | read-only | current | NID Series card Port3 duplex status 0: Half 1: Full |
| 1.3.6.1.4.1.4756.20.502.20.1.55 | ColumnnidPort3RxPausestsRemoteB | read-only | current | NID Series card Port3 rx pause status 0: No 1: Yes |
| 1.3.6.1.4.1.4756.20.502.20.1.56 | ColumnnidPort3TxPausestsRemoteB | read-only | current | NID Series card Port3 tx pause status 0: No 1: Yes |
| 1.3.6.1.4.1.4756.20.502.20.1.57 | ColumnnidPort4LinkstsRemoteB | read-only | current | NID Series card Port4 link status: 0:Link down 1:Link up |
| 1.3.6.1.4.1.4756.20.502.20.1.58 | ColumnnidPort4SpeedstsRemoteB | read-only | current | NID Series card Port4 speed status 10Base-T 100Base-Tx 1000Base-Tx |
| 1.3.6.1.4.1.4756.20.502.20.1.59 | ColumnnidPort4DuplexstsRemoteB | read-only | current | NID Series card Port4 duplex status 0: Half 1: Full |
| 1.3.6.1.4.1.4756.20.502.20.1.60 | ColumnnidPort4RxPausestsRemoteB | read-only | current | NID Series card Port4 rx pause status 0: No 1: Yes |
| 1.3.6.1.4.1.4756.20.502.20.1.61 | ColumnnidPort4TxPausestsRemoteB | read-only | current | NID Series card Port4 tx pause status 0: No 1: Yes |
| 1.3.6.1.4.1.4756.20.502.20.1.62 | ColumnnidPort5LinkstsRemoteB | read-only | current | NID Series card Port5 link status: 0:Link down 1:Link up |
| 1.3.6.1.4.1.4756.20.502.20.1.63 | ColumnnidPort5SpeedstsRemoteB | read-only | current | NID Series card Port5 speed status 10Base-T 100Base-Tx 1000Base-Tx |
| 1.3.6.1.4.1.4756.20.502.20.1.64 | ColumnnidPort5DuplexstsRemoteB | read-only | current | NID Series card Port5 duplex status 0: Half 1: Full |
| 1.3.6.1.4.1.4756.20.502.20.1.65 | ColumnnidPort5RxPausestsRemoteB | read-only | current | NID Series card Port5 rx pause status 0: No 1: Yes |
| 1.3.6.1.4.1.4756.20.502.20.1.66 | ColumnnidPort5TxPausestsRemoteB | read-only | current | NID Series card Port5 tx pause status 0: No 1: Yes |
| 1.3.6.1.4.1.4756.20.502.20.1.67 | ColumnnidPort6LinkstsRemoteB | read-only | current | NID Series card Port6 link status: 0:Link down 1:Link up |
| 1.3.6.1.4.1.4756.20.502.20.1.68 | ColumnnidPort6SpeedstsRemoteB | read-only | current | NID Series card Port6 speed status 10Base-T 100Base-Tx 1000Base-Tx |
| 1.3.6.1.4.1.4756.20.502.20.1.69 | ColumnnidPort6DuplexstsRemoteB | read-only | current | NID Series card Port6 duplex status 0: Half 1: Full |
| 1.3.6.1.4.1.4756.20.502.20.1.70 | ColumnnidPort6RxPausestsRemoteB | read-only | current | NID Series card Port6 rx pause status 0: No 1: Yes |
| 1.3.6.1.4.1.4756.20.502.20.1.71 | ColumnnidPort6TxPausestsRemoteB | read-only | current | NID Series card Port6 tx pause status 0: No 1: Yes |
| 1.3.6.1.4.1.4756.20.502.20.1.72 | ColumnnidPort7LinkstsRemoteB | read-only | current | NID Series card Port7 link status: 0:Link down 1:Link up |
| 1.3.6.1.4.1.4756.20.502.20.1.73 | ColumnnidPort7SpeedstsRemoteB | read-only | current | NID Series card Port7 speed status 10Base-T 100Base-Tx 1000Base-Tx |
| 1.3.6.1.4.1.4756.20.502.20.1.74 | ColumnnidPort7DuplexstsRemoteB | read-only | current | NID Series card Port7 duplex status 0: Half 1: Full |
| 1.3.6.1.4.1.4756.20.502.20.1.75 | ColumnnidPort7RxPausestsRemoteB | read-only | current | NID Series card Port7 rx pause status 0: No 1: Yes |
| 1.3.6.1.4.1.4756.20.502.20.1.76 | ColumnnidPort7TxPausestsRemoteB | read-only | current | NID Series card Port7 tx pause status 0: No 1: Yes |
| 1.3.6.1.4.1.4756.20.502.20.1.77 | ColumnnidPort8LinkstsRemoteB | read-only | current | NID Series card Port8 link status: 0:Link down 1:Link up |
| 1.3.6.1.4.1.4756.20.502.20.1.78 | ColumnnidPort8SpeedstsRemoteB | read-only | current | NID Series card Port8 speed status 10Base-T 100Base-Tx 1000Base-Tx |
| 1.3.6.1.4.1.4756.20.502.20.1.79 | ColumnnidPort8DuplexstsRemoteB | read-only | current | NID Series card Port8 duplex status 0: Half 1: Full |
| 1.3.6.1.4.1.4756.20.502.20.1.80 | ColumnnidPort8RxPausestsRemoteB | read-only | current | NID Series card Port8 rx pause status 0: No 1: Yes |
| 1.3.6.1.4.1.4756.20.502.20.1.81 | ColumnnidPort8TxPausestsRemoteB | read-only | current | NID Series card Port8 tx pause status 0: No 1: Yes |
| 1.3.6.1.4.1.4756.20.502.20.1.82 | ColumnnidPort1SpeedConfRemoteB | read-write | current | NID Series card Port1 speed config 0: disable 1: auto 2: 100M FDX 3: 1G FDX 4: 2.5G FDX |
| 1.3.6.1.4.1.4756.20.502.20.1.83 | ColumnnidPort1flowConrolRemoteB | read-write | current | NID Series card Port1 flow control config 0: no 1: yes |
| 1.3.6.1.4.1.4756.20.502.20.1.84 | ColumnnidPort1MaxFrameRemoteB | read-write | current | NID Series card Port1 max frame config |
| 1.3.6.1.4.1.4756.20.502.20.1.85 | ColumnnidPort1ALSRemoteB | read-write | current | NID Series card Port1 auto laser shutdown: 0: Disable 1: Enable |
| 1.3.6.1.4.1.4756.20.502.20.1.86 | ColumnnidPort2SpeedConfRemoteB | read-write | current | NID Series card Port2 speed config 0: disable 1: auto 2: 100M FDX 3: 1G FDX 4: 2.5G FDX |
| 1.3.6.1.4.1.4756.20.502.20.1.87 | ColumnnidPort2flowConrolRemoteB | read-write | current | NID Series card Port2 flow control config 0: no 1: yes |
| 1.3.6.1.4.1.4756.20.502.20.1.88 | ColumnnidPort2MaxFrameRemoteB | read-write | current | NID Series card Port2 max frame config |
| 1.3.6.1.4.1.4756.20.502.20.1.89 | ColumnnidPort2ALSRemoteB | read-write | current | NID Series card Port2 auto laser shutdown: 0: Disable 1: Enable |
| 1.3.6.1.4.1.4756.20.502.20.1.90 | ColumnnidPort3SpeedConfRemoteB | read-write | current | NID Series card Port3 speed config 0: disable 1: auto 2: 100M FDX 3: 1G FDX |
| 1.3.6.1.4.1.4756.20.502.20.1.91 | ColumnnidPort3flowConrolRemoteB | read-write | current | NID Series card Port3 flow control config 0: no 1: yes |
| 1.3.6.1.4.1.4756.20.502.20.1.92 | ColumnnidPort3MaxFrameRemoteB | read-write | current | NID Series card Port3 max frame config |
| 1.3.6.1.4.1.4756.20.502.20.1.93 | ColumnnidPort3ALSRemoteB | read-write | current | NID Series card Port3 auto laser shutdown: 0: Disable 1: Enable |
| 1.3.6.1.4.1.4756.20.502.20.1.94 | ColumnnidPort4SpeedConfRemoteB | read-write | current | NID Series card Port4 speed config 0: disable 1: auto 2: 100M FDX 3: 1G FDX |
| 1.3.6.1.4.1.4756.20.502.20.1.95 | ColumnnidPort4flowConrolRemoteB | read-write | current | NID Series card Port4 flow control config 0: no 1: yes |
| 1.3.6.1.4.1.4756.20.502.20.1.96 | ColumnnidPort4MaxFrameRemoteB | read-write | current | NID Series card Port4 max frame config |
| 1.3.6.1.4.1.4756.20.502.20.1.97 | ColumnnidPort4ALSRemoteB | read-write | current | NID Series card Port4 auto laser shutdown: 0: Disable 1: Enable |
| 1.3.6.1.4.1.4756.20.502.20.1.98 | ColumnnidPort5SpeedConfRemoteB | read-write | current | NID Series card Port5 speed config 0: disable 1: auto 2: 10M HDX 3: 10M FDX 4: 100M HDX 5: 100M FDX 6: 1G FDX |
| 1.3.6.1.4.1.4756.20.502.20.1.99 | ColumnnidPort5flowConrolRemoteB | read-write | current | NID Series card Port5 flow control config 0: no 1: yes |
| 1.3.6.1.4.1.4756.20.502.20.1.100 | ColumnnidPort5MaxFrameRemoteB | read-write | current | NID Series card Port5 max frame config |
| 1.3.6.1.4.1.4756.20.502.20.1.101 | ColumnnidPort5CollisionModeRemoteB | read-write | current | NID Series card Port5 collision mode config. 0: Discard 1: Restart |
| 1.3.6.1.4.1.4756.20.502.20.1.102 | ColumnnidPort6SpeedConfRemoteB | read-write | current | NID Series card Port6 speed config 0: disable 1: auto 2: 10M HDX 3: 10M FDX 4: 100M HDX 5: 100M FDX 6: 1G FDX |
| 1.3.6.1.4.1.4756.20.502.20.1.103 | ColumnnidPort6flowConrolRemoteB | read-write | current | NID Series card Port6 flow control config 0: no 1: yes |
| 1.3.6.1.4.1.4756.20.502.20.1.104 | ColumnnidPort6MaxFrameRemoteB | read-write | current | NID Series card Port6 max frame config |
| 1.3.6.1.4.1.4756.20.502.20.1.105 | ColumnnidPort6CollisionModeRemoteB | read-write | current | NID Series card Port6 collision mode config. 0: Discard 1: Restart |
| 1.3.6.1.4.1.4756.20.502.20.1.106 | ColumnnidPort7SpeedConfRemoteB | read-write | current | NID Series card Port7 speed config 0: disable 1: auto 2: 10M HDX 3: 10M FDX 4: 100M HDX 5: 100M FDX 6: 1G FDX |
| 1.3.6.1.4.1.4756.20.502.20.1.107 | ColumnnidPort7flowConrolRemoteB | read-write | current | NID Series card Port7 flow control config 0: no 1: yes |
| 1.3.6.1.4.1.4756.20.502.20.1.108 | ColumnnidPort7MaxFrameRemoteB | read-write | current | NID Series card Port7 max frame config |
| 1.3.6.1.4.1.4756.20.502.20.1.109 | ColumnnidPort7CollisionModeRemoteB | read-write | current | NID Series card Port7 collision mode config. 0: Discard 1: Restart |
| 1.3.6.1.4.1.4756.20.502.20.1.110 | ColumnnidPort8SpeedConfRemoteB | read-write | current | NID Series card Port8 speed config 0: disable 1: auto 2: 10M HDX 3: 10M FDX 4: 100M HDX 5: 100M FDX 6: 1G FDX |
| 1.3.6.1.4.1.4756.20.502.20.1.111 | ColumnnidPort8flowConrolRemoteB | read-write | current | NID Series card Port8 flow control config 0: no 1: yes |
| 1.3.6.1.4.1.4756.20.502.20.1.112 | ColumnnidPort8MaxFrameRemoteB | read-write | current | NID Series card Port8 max frame config |
| 1.3.6.1.4.1.4756.20.502.20.1.113 | ColumnnidPort8CollisionModeRemoteB | read-write | current | NID Series card Port8 collision mode config. 0: Discard 1: Restart |
| 1.3.6.1.4.1.4756.20.502.20.1.114 | ColumnnidPort1LLFLogicRemoteB | read-write | current | NID Series card Port1 link loss forwarding - Logic 0: AND 1: OR |
| 1.3.6.1.4.1.4756.20.502.20.1.115 | ColumnnidPort1LLFLogicPort2RemoteB | read-write | current | NID Series card Port1 link loss forwarding - Link/Rx Loss Port2 0: NO 1: YES |
| 1.3.6.1.4.1.4756.20.502.20.1.116 | ColumnnidPort1LLFLogicPort3RemoteB | read-write | current | NID Series card Port1 link loss forwarding - Link/Rx Loss Port3 0: NO 1: YES |
| 1.3.6.1.4.1.4756.20.502.20.1.117 | ColumnnidPort1LLFLogicPort4RemoteB | read-write | current | NID Series card Port1 link loss forwarding - Link/Rx Loss Port4 0: NO 1: YES |
| 1.3.6.1.4.1.4756.20.502.20.1.118 | ColumnnidPort1LLFLogicPort5RemoteB | read-write | current | NID Series card Port1 link loss forwarding - Link/Rx Loss Port5 0: NO 1: YES |
| 1.3.6.1.4.1.4756.20.502.20.1.119 | ColumnnidPort1LLFLogicPort6RemoteB | read-write | current | NID Series card Port1 link loss forwarding - Link/Rx Loss Port6 0: NO 1: YES |
| 1.3.6.1.4.1.4756.20.502.20.1.120 | ColumnnidPort1LLFLogicPort7RemoteB | read-write | current | NID Series card Port1 link loss forwarding - Link/Rx Loss Port7 0: NO 1: YES |
| 1.3.6.1.4.1.4756.20.502.20.1.121 | ColumnnidPort1LLFLogicPort8RemoteB | read-write | current | NID Series card Port1 link loss forwarding - Link/Rx Loss Port8 0: NO 1: YES |
| 1.3.6.1.4.1.4756.20.502.20.1.122 | ColumnnidPort2LLFLogicRemoteB | read-write | current | NID Series card Port2 link loss forwarding - Logic 0: AND 1: OR |
| 1.3.6.1.4.1.4756.20.502.20.1.123 | ColumnnidPort2LLFLogicPort1RemoteB | read-write | current | NID Series card Port2 link loss forwarding - Link/Rx Loss Port1 0: NO 1: YES |
| 1.3.6.1.4.1.4756.20.502.20.1.124 | ColumnnidPort2LLFLogicPort3RemoteB | read-write | current | NID Series card Port2 link loss forwarding - Link/Rx Loss Port3 0: NO 1: YES |
| 1.3.6.1.4.1.4756.20.502.20.1.125 | ColumnnidPort2LLFLogicPort4RemoteB | read-write | current | NID Series card Port2 link loss forwarding - Link/Rx Loss Port4 0: NO 1: YES |
| 1.3.6.1.4.1.4756.20.502.20.1.126 | ColumnnidPort2LLFLogicPort5RemoteB | read-write | current | NID Series card Port2 link loss forwarding - Link/Rx Loss Port54 0: NO 1: YES |
| 1.3.6.1.4.1.4756.20.502.20.1.127 | ColumnnidPort2LLFLogicPort6RemoteB | read-write | current | NID Series card Port2 link loss forwarding - Link/Rx Loss Port6 0: NO 1: YES |
| 1.3.6.1.4.1.4756.20.502.20.1.128 | ColumnnidPort2LLFLogicPort7RemoteB | read-write | current | NID Series card Port2 link loss forwarding - Link/Rx Loss Port7 0: NO 1: YES |
| 1.3.6.1.4.1.4756.20.502.20.1.129 | ColumnnidPort2LLFLogicPort8RemoteB | read-write | current | NID Series card Port2 link loss forwarding - Link/Rx Loss Port8 0: NO 1: YES |
| 1.3.6.1.4.1.4756.20.502.20.1.130 | ColumnnidPort3LLFLogicRemoteB | read-write | current | NID Series card Port1 link loss forwarding - Logic 0: AND 1: OR |
| 1.3.6.1.4.1.4756.20.502.20.1.131 | ColumnnidPort3LLFLogicPort1RemoteB | read-write | current | NID Series card Port3 link loss forwarding - Link/Rx Loss Port1 0: NO 1: YES |
| 1.3.6.1.4.1.4756.20.502.20.1.132 | ColumnnidPort3LLFLogicPort2RemoteB | read-write | current | NID Series card Port3 link loss forwarding - Link/Rx Loss Port2 0: NO 1: YES |
| 1.3.6.1.4.1.4756.20.502.20.1.133 | ColumnnidPort3LLFLogicPort4RemoteB | read-write | current | NID Series card Port3 link loss forwarding - Link/Rx Loss Port4 0: NO 1: YES |
| 1.3.6.1.4.1.4756.20.502.20.1.134 | ColumnnidPort3LLFLogicPort5RemoteB | read-write | current | NID Series card Port3 link loss forwarding - Link/Rx Loss Port5 0: NO 1: YES |
| 1.3.6.1.4.1.4756.20.502.20.1.135 | ColumnnidPort3LLFLogicPort6RemoteB | read-write | current | NID Series card Port3 link loss forwarding - Link/Rx Loss Port6 0: NO 1: YES |
| 1.3.6.1.4.1.4756.20.502.20.1.136 | ColumnnidPort3LLFLogicPort7RemoteB | read-write | current | NID Series card Port3 link loss forwarding - Link/Rx Loss Port7 0: NO 1: YES |
| 1.3.6.1.4.1.4756.20.502.20.1.137 | ColumnnidPort3LLFLogicPort8RemoteB | read-write | current | NID Series card Port3 link loss forwarding - Link/Rx Loss Port8 0: NO 1: YES |
| 1.3.6.1.4.1.4756.20.502.20.1.138 | ColumnnidPort4LLFLogicRemoteB | read-write | current | NID Series card Port4 link loss forwarding - Logic 0: AND 1: OR |
| 1.3.6.1.4.1.4756.20.502.20.1.139 | ColumnnidPort4LLFLogicPort1RemoteB | read-write | current | NID Series card Port4 link loss forwarding - Link/Rx Loss Port1 0: NO 1: YES |
| 1.3.6.1.4.1.4756.20.502.20.1.140 | ColumnnidPort4LLFLogicPort2RemoteB | read-write | current | NID Series card Port4 link loss forwarding - Link/Rx Loss Port2 0: NO 1: YES |
| 1.3.6.1.4.1.4756.20.502.20.1.141 | ColumnnidPort4LLFLogicPort3RemoteB | read-write | current | NID Series card Port4 link loss forwarding - Link/Rx Loss Port3 0: NO 1: YES |
| 1.3.6.1.4.1.4756.20.502.20.1.142 | ColumnnidPort4LLFLogicPort5RemoteB | read-write | current | NID Series card Port4 link loss forwarding - Link/Rx Loss Port5 0: NO 1: YES |
| 1.3.6.1.4.1.4756.20.502.20.1.143 | ColumnnidPort4LLFLogicPort6RemoteB | read-write | current | NID Series card Port4 link loss forwarding - Link/Rx Loss Port6 0: NO 1: YES |
| 1.3.6.1.4.1.4756.20.502.20.1.144 | ColumnnidPort4LLFLogicPort7RemoteB | read-write | current | NID Series card Port4 link loss forwarding - Link/Rx Loss Port7 0: NO 1: YES |
| 1.3.6.1.4.1.4756.20.502.20.1.145 | ColumnnidPort4LLFLogicPort8RemoteB | read-write | current | NID Series card Port4 link loss forwarding - Link/Rx Loss Port8 0: NO 1: YES |
| 1.3.6.1.4.1.4756.20.502.20.1.146 | ColumnnidPort5LLFLogicRemoteB | read-write | current | NID Series card Port5 link loss forwarding - Logic 0: AND 1: OR |
| 1.3.6.1.4.1.4756.20.502.20.1.147 | ColumnnidPort5LLFLogicPort1RemoteB | read-write | current | NID Series card Port5 link loss forwarding - Link/Rx Loss Port1 0: NO 1: YES |
| 1.3.6.1.4.1.4756.20.502.20.1.148 | ColumnnidPort5LLFLogicPort2RemoteB | read-write | current | NID Series card Port5 link loss forwarding - Link/Rx Loss Port2 0: NO 1: YES |
| 1.3.6.1.4.1.4756.20.502.20.1.149 | ColumnnidPort5LLFLogicPort3RemoteB | read-write | current | NID Series card Port5 link loss forwarding - Link/Rx Loss Port3 0: NO 1: YES |
| 1.3.6.1.4.1.4756.20.502.20.1.150 | ColumnnidPort5LLFLogicPort4RemoteB | read-write | current | NID Series card Port5 link loss forwarding - Link/Rx Loss Port4 0: NO 1: YES |
| 1.3.6.1.4.1.4756.20.502.20.1.151 | ColumnnidPort5LLFLogicPort6RemoteB | read-write | current | NID Series card Port5 link loss forwarding - Link/Rx Loss Port6 0: NO 1: YES |
| 1.3.6.1.4.1.4756.20.502.20.1.152 | ColumnnidPort5LLFLogicPort7RemoteB | read-write | current | NID Series card Port5 link loss forwarding - Link/Rx Loss Port7 0: NO 1: YES |
| 1.3.6.1.4.1.4756.20.502.20.1.153 | ColumnnidPort5LLFLogicPort8RemoteB | read-write | current | NID Series card Port5 link loss forwarding - Link/Rx Loss Port8 0: NO 1: YES |
| 1.3.6.1.4.1.4756.20.502.20.1.154 | ColumnnidPort6LLFLogicRemoteB | read-write | current | NID Series card Port6 link loss forwarding - Logic 0: AND 1: OR |
| 1.3.6.1.4.1.4756.20.502.20.1.155 | ColumnnidPort6LLFLogicPort1RemoteB | read-write | current | NID Series card Port6 link loss forwarding - Link/Rx Loss Port1 0: NO 1: YES |
| 1.3.6.1.4.1.4756.20.502.20.1.156 | ColumnnidPort6LLFLogicPort2RemoteB | read-write | current | NID Series card Port6 link loss forwarding - Link/Rx Loss Port2 0: NO 1: YES |
| 1.3.6.1.4.1.4756.20.502.20.1.157 | ColumnnidPort6LLFLogicPort3RemoteB | read-write | current | NID Series card Port6 link loss forwarding - Link/Rx Loss Port3 0: NO 1: YES |
| 1.3.6.1.4.1.4756.20.502.20.1.158 | ColumnnidPort6LLFLogicPort4RemoteB | read-write | current | NID Series card Port6 link loss forwarding - Link/Rx Loss Port4 0: NO 1: YES |
| 1.3.6.1.4.1.4756.20.502.20.1.159 | ColumnnidPort6LLFLogicPort5RemoteB | read-write | current | NID Series card Port6 link loss forwarding - Link/Rx Loss Port5 0: NO 1: YES |
| 1.3.6.1.4.1.4756.20.502.20.1.160 | ColumnnidPort6LLFLogicPort7RemoteB | read-write | current | NID Series card Port4 link loss forwarding - Link/Rx Loss Port7 0: NO 1: YES |
| 1.3.6.1.4.1.4756.20.502.20.1.161 | ColumnnidPort6LLFLogicPort8RemoteB | read-write | current | NID Series card Port6 link loss forwarding - Link/Rx Loss Port8 0: NO 1: YES |
| 1.3.6.1.4.1.4756.20.502.20.1.162 | ColumnnidPort7LLFLogicRemoteB | read-write | current | NID Series card Port7 link loss forwarding - Logic 0: AND 1: OR |
| 1.3.6.1.4.1.4756.20.502.20.1.163 | ColumnnidPort7LLFLogicPort1RemoteB | read-write | current | NID Series card Port7 link loss forwarding - Link/Rx Loss Port1 0: NO 1: YES |
| 1.3.6.1.4.1.4756.20.502.20.1.164 | ColumnnidPort7LLFLogicPort2RemoteB | read-write | current | NID Series card Port7 link loss forwarding - Link/Rx Loss Port2 0: NO 1: YES |
| 1.3.6.1.4.1.4756.20.502.20.1.165 | ColumnnidPort7LLFLogicPort3RemoteB | read-write | current | NID Series card Port7 link loss forwarding - Link/Rx Loss Port3 0: NO 1: YES |
| 1.3.6.1.4.1.4756.20.502.20.1.166 | ColumnnidPort7LLFLogicPort4RemoteB | read-write | current | NID Series card Port7 link loss forwarding - Link/Rx Loss Port4 0: NO 1: YES |
| 1.3.6.1.4.1.4756.20.502.20.1.167 | ColumnnidPort7LLFLogicPort5RemoteB | read-write | current | NID Series card Port7 link loss forwarding - Link/Rx Loss Port5 0: NO 1: YES |
| 1.3.6.1.4.1.4756.20.502.20.1.168 | ColumnnidPort7LLFLogicPort6RemoteB | read-write | current | NID Series card Port4 link loss forwarding - Link/Rx Loss Port6 0: NO 1: YES |
| 1.3.6.1.4.1.4756.20.502.20.1.169 | ColumnnidPort7LLFLogicPort8RemoteB | read-write | current | NID Series card Port7 link loss forwarding - Link/Rx Loss Port8 0: NO 1: YES |
| 1.3.6.1.4.1.4756.20.502.20.1.170 | ColumnnidPort8LLFLogicRemoteB | read-write | current | NID Series card Port8 link loss forwarding - Logic 0: AND 1: OR |
| 1.3.6.1.4.1.4756.20.502.20.1.171 | ColumnnidPort8LLFLogicPort1RemoteB | read-write | current | NID Series card Port8 link loss forwarding - Link/Rx Loss Port1 0: NO 1: YES |
| 1.3.6.1.4.1.4756.20.502.20.1.172 | ColumnnidPort8LLFLogicPort2RemoteB | read-write | current | NID Series card Port8 link loss forwarding - Link/Rx Loss Port2 0: NO 1: YES |
| 1.3.6.1.4.1.4756.20.502.20.1.173 | ColumnnidPort8LLFLogicPort3RemoteB | read-write | current | NID Series card Port5 link loss forwarding - Link/Rx Loss Port3 0: NO 1: YES |
| 1.3.6.1.4.1.4756.20.502.20.1.174 | ColumnnidPort8LLFLogicPort4RemoteB | read-write | current | NID Series card Port8 link loss forwarding - Link/Rx Loss Port4 0: NO 1: YES |
| 1.3.6.1.4.1.4756.20.502.20.1.175 | ColumnnidPort8LLFLogicPort5RemoteB | read-write | current | NID Series card Port8 link loss forwarding - Link/Rx Loss Port5 0: NO 1: YES |
| 1.3.6.1.4.1.4756.20.502.20.1.176 | ColumnnidPort8LLFLogicPort6RemoteB | read-write | current | NID Series card Port8 link loss forwarding - Link/Rx Loss Port6 0: NO 1: YES |
| 1.3.6.1.4.1.4756.20.502.20.1.177 | ColumnnidPort8LLFLogicPort7RemoteB | read-write | current | NID Series card Port8 link loss forwarding - Link/Rx Loss Port7 0: NO 1: YES |
| 1.3.6.1.4.1.4756.20.502.20.1.178 | ColumnnidPort1PacketsRxRemoteB | read-only | current | NID Series card port1 traffic overview:: Packets Rx |
| 1.3.6.1.4.1.4756.20.502.20.1.179 | ColumnnidPort1PacketsTxRemoteB | read-only | current | NID Series card port1 traffic overview:: Packets Tx |
| 1.3.6.1.4.1.4756.20.502.20.1.180 | ColumnnidPort1BytesRxRemoteB | read-only | current | NID Series card port1 traffic overview:: Bytes Rx |
| 1.3.6.1.4.1.4756.20.502.20.1.181 | ColumnnidPort1BytesTxRemoteB | read-only | current | NID Series card port1 traffic overview:: Bytes Tx |
| 1.3.6.1.4.1.4756.20.502.20.1.182 | ColumnnidPort1ErrorsRxRemoteB | read-only | current | NID Series card port1 traffic overview:: Errors Rx |
| 1.3.6.1.4.1.4756.20.502.20.1.183 | ColumnnidPort1ErrorsTxRemoteB | read-only | current | NID Series card port1 traffic overview:: Errors Tx |
| 1.3.6.1.4.1.4756.20.502.20.1.184 | ColumnnidPort1DropsRxRemoteB | read-only | current | NID Series card port1 traffic overview:: Drops Rx |
| 1.3.6.1.4.1.4756.20.502.20.1.185 | ColumnnidPort1DropsTxRemoteB | read-only | current | NID Series card port1 traffic overview:: Drops Tx |
| 1.3.6.1.4.1.4756.20.502.20.1.186 | ColumnnidPort1FilteredRxRemoteB | read-only | current | NID Series card port1 traffic overview:: Filtered Rx |
| 1.3.6.1.4.1.4756.20.502.20.1.187 | ColumnnidPort2PacketsRxRemoteB | read-only | current | NID Series card port2 traffic overview:: Packets Rx |
| 1.3.6.1.4.1.4756.20.502.20.1.188 | ColumnnidPort2PacketsTxRemoteB | read-only | current | NID Series card port2 traffic overview:: Packets Tx |
| 1.3.6.1.4.1.4756.20.502.20.1.189 | ColumnnidPort2BytesRxRemoteB | read-only | current | NID Series card port2 traffic overview:: Bytes Rx |
| 1.3.6.1.4.1.4756.20.502.20.1.190 | ColumnnidPort2BytesTxRemoteB | read-only | current | NID Series card port2 traffic overview:: Bytes Tx |
| 1.3.6.1.4.1.4756.20.502.20.1.191 | ColumnnidPort2ErrorsRxRemoteB | read-only | current | NID Series card port2 traffic overview:: Errors Rx |
| 1.3.6.1.4.1.4756.20.502.20.1.192 | ColumnnidPort2ErrorsTxRemoteB | read-only | current | NID Series card port2 traffic overview:: Errors Tx |
| 1.3.6.1.4.1.4756.20.502.20.1.193 | ColumnnidPort2DropsRxRemoteB | read-only | current | NID Series card port2 traffic overview:: Drops Rx |
| 1.3.6.1.4.1.4756.20.502.20.1.194 | ColumnnidPort2DropsTxRemoteB | read-only | current | NID Series card port2 traffic overview:: Drops Tx |
| 1.3.6.1.4.1.4756.20.502.20.1.195 | ColumnnidPort2FilteredRxRemoteB | read-only | current | NID Series card port2 traffic overview:: Filtered Rx |
| 1.3.6.1.4.1.4756.20.502.20.1.196 | ColumnnidPort3PacketsRxRemoteB | read-only | current | NID Series card port3 traffic overview:: Packets Rx |
| 1.3.6.1.4.1.4756.20.502.20.1.197 | ColumnnidPort3PacketsTxRemoteB | read-only | current | NID Series card port3 traffic overview:: Packets Tx |
| 1.3.6.1.4.1.4756.20.502.20.1.198 | ColumnnidPort3BytesRxRemoteB | read-only | current | NID Series card port3 traffic overview:: Bytes Rx |
| 1.3.6.1.4.1.4756.20.502.20.1.199 | ColumnnidPort3BytesTxRemoteB | read-only | current | NID Series card port3 traffic overview:: Bytes Tx |
| 1.3.6.1.4.1.4756.20.502.20.1.200 | ColumnnidPort3ErrorsRxRemoteB | read-only | current | NID Series card port3 traffic overview:: Errors Rx |
| 1.3.6.1.4.1.4756.20.502.20.1.201 | ColumnnidPort3ErrorsTxRemoteB | read-only | current | NID Series card port3 traffic overview:: Errors Tx |
| 1.3.6.1.4.1.4756.20.502.20.1.202 | ColumnnidPort3DropsRxRemoteB | read-only | current | NID Series card port3 traffic overview:: Drops Rx |
| 1.3.6.1.4.1.4756.20.502.20.1.203 | ColumnnidPort3DropsTxRemoteB | read-only | current | NID Series card port3 traffic overview:: Drops Tx |
| 1.3.6.1.4.1.4756.20.502.20.1.204 | ColumnnidPort3FilteredRxRemoteB | read-only | current | NID Series card port3 traffic overview:: Filtered Rx |
| 1.3.6.1.4.1.4756.20.502.20.1.205 | ColumnnidPort4PacketsRxRemoteB | read-only | current | NID Series card port4 traffic overview:: Packets Rx |
| 1.3.6.1.4.1.4756.20.502.20.1.206 | ColumnnidPort4PacketsTxRemoteB | read-only | current | NID Series card port4 traffic overview:: Packets Tx |
| 1.3.6.1.4.1.4756.20.502.20.1.207 | ColumnnidPort4BytesRxRemoteB | read-only | current | NID Series card port4 traffic overview:: Bytes Rx |
| 1.3.6.1.4.1.4756.20.502.20.1.208 | ColumnnidPort4BytesTxRemoteB | read-only | current | NID Series card port4 traffic overview:: Bytes Tx |
| 1.3.6.1.4.1.4756.20.502.20.1.209 | ColumnnidPort4ErrorsRxRemoteB | read-only | current | NID Series card port4 traffic overview:: Errors Rx |
| 1.3.6.1.4.1.4756.20.502.20.1.210 | ColumnnidPort4ErrorsTxRemoteB | read-only | current | NID Series card port4 traffic overview:: Errors Tx |
| 1.3.6.1.4.1.4756.20.502.20.1.211 | ColumnnidPort4DropsRxRemoteB | read-only | current | NID Series card port4 traffic overview:: Drops Rx |
| 1.3.6.1.4.1.4756.20.502.20.1.212 | ColumnnidPort4DropsTxRemoteB | read-only | current | NID Series card port4 traffic overview:: Drops Tx |
| 1.3.6.1.4.1.4756.20.502.20.1.213 | ColumnnidPort4FilteredRxRemoteB | read-only | current | NID Series card port4 traffic overview:: Filtered Rx |
| 1.3.6.1.4.1.4756.20.502.20.1.214 | ColumnnidPort5PacketsRxRemoteB | read-only | current | NID Series card port5 traffic overview:: Packets Rx |
| 1.3.6.1.4.1.4756.20.502.20.1.215 | ColumnnidPort5PacketsTxRemoteB | read-only | current | NID Series card port5 traffic overview:: Packets Tx |
| 1.3.6.1.4.1.4756.20.502.20.1.216 | ColumnnidPort5BytesRxRemoteB | read-only | current | NID Series card port5 traffic overview:: Bytes Rx |
| 1.3.6.1.4.1.4756.20.502.20.1.217 | ColumnnidPort5BytesTxRemoteB | read-only | current | NID Series card port5 traffic overview:: Bytes Tx |
| 1.3.6.1.4.1.4756.20.502.20.1.218 | ColumnnidPort5ErrorsRxRemoteB | read-only | current | NID Series card port5 traffic overview:: Errors Rx |
| 1.3.6.1.4.1.4756.20.502.20.1.219 | ColumnnidPort5ErrorsTxRemoteB | read-only | current | NID Series card port5 traffic overview:: Errors Tx |
| 1.3.6.1.4.1.4756.20.502.20.1.220 | ColumnnidPort5DropsRxRemoteB | read-only | current | NID Series card port5 traffic overview:: Drops Rx |
| 1.3.6.1.4.1.4756.20.502.20.1.221 | ColumnnidPort5DropsTxRemoteB | read-only | current | NID Series card port5 traffic overview:: Drops Tx |
| 1.3.6.1.4.1.4756.20.502.20.1.222 | ColumnnidPort5FilteredRxRemoteB | read-only | current | NID Series card port5 traffic overview:: Filtered Rx |
| 1.3.6.1.4.1.4756.20.502.20.1.223 | ColumnnidPort6PacketsRxRemoteB | read-only | current | NID Series card port6 traffic overview:: Packets Rx |
| 1.3.6.1.4.1.4756.20.502.20.1.224 | ColumnnidPort6PacketsTxRemoteB | read-only | current | NID Series card port6 traffic overview:: Packets Tx |
| 1.3.6.1.4.1.4756.20.502.20.1.225 | ColumnnidPort6BytesRxRemoteB | read-only | current | NID Series card port6 traffic overview:: Bytes Rx |
| 1.3.6.1.4.1.4756.20.502.20.1.226 | ColumnnidPort6BytesTxRemoteB | read-only | current | NID Series card port6 traffic overview:: Bytes Tx |
| 1.3.6.1.4.1.4756.20.502.20.1.227 | ColumnnidPort6ErrorsRxRemoteB | read-only | current | NID Series card port6 traffic overview:: Errors Rx |
| 1.3.6.1.4.1.4756.20.502.20.1.228 | ColumnnidPort6ErrorsTxRemoteB | read-only | current | NID Series card port6 traffic overview:: Errors Tx |
| 1.3.6.1.4.1.4756.20.502.20.1.229 | ColumnnidPort6DropsRxRemoteB | read-only | current | NID Series card port6 traffic overview:: Drops Rx |
| 1.3.6.1.4.1.4756.20.502.20.1.230 | ColumnnidPort6DropsTxRemoteB | read-only | current | NID Series card port6 traffic overview:: Drops Tx |
| 1.3.6.1.4.1.4756.20.502.20.1.231 | ColumnnidPort6FilteredRxRemoteB | read-only | current | NID Series card port6 traffic overview:: Filtered Rx |
| 1.3.6.1.4.1.4756.20.502.20.1.232 | ColumnnidPort7PacketsRxRemoteB | read-only | current | NID Series card port7 traffic overview:: Packets Rx |
| 1.3.6.1.4.1.4756.20.502.20.1.233 | ColumnnidPort7PacketsTxRemoteB | read-only | current | NID Series card port7 traffic overview:: Packets Tx |
| 1.3.6.1.4.1.4756.20.502.20.1.234 | ColumnnidPort7BytesRxRemoteB | read-only | current | NID Series card port7 traffic overview:: Bytes Rx |
| 1.3.6.1.4.1.4756.20.502.20.1.235 | ColumnnidPort7BytesTxRemoteB | read-only | current | NID Series card port7 traffic overview:: Bytes Tx |
| 1.3.6.1.4.1.4756.20.502.20.1.236 | ColumnnidPort7ErrorsRxRemoteB | read-only | current | NID Series card port7 traffic overview:: Errors Rx |
| 1.3.6.1.4.1.4756.20.502.20.1.237 | ColumnnidPort7ErrorsTxRemoteB | read-only | current | NID Series card port7 traffic overview:: Errors Tx |
| 1.3.6.1.4.1.4756.20.502.20.1.238 | ColumnnidPort7DropsRxRemoteB | read-only | current | NID Series card port7 traffic overview:: Drops Rx |
| 1.3.6.1.4.1.4756.20.502.20.1.239 | ColumnnidPort7DropsTxRemoteB | read-only | current | NID Series card port7 traffic overview:: Drops Tx |
| 1.3.6.1.4.1.4756.20.502.20.1.240 | ColumnnidPort7FilteredRxRemoteB | read-only | current | NID Series card port7 traffic overview:: Filtered Rx |
| 1.3.6.1.4.1.4756.20.502.20.1.241 | ColumnnidPort8PacketsRxRemoteB | read-only | current | NID Series card port8 traffic overview:: Packets Rx |
| 1.3.6.1.4.1.4756.20.502.20.1.242 | ColumnnidPort8PacketsTxRemoteB | read-only | current | NID Series card port8 traffic overview:: Packets Tx |
| 1.3.6.1.4.1.4756.20.502.20.1.243 | ColumnnidPort8BytesRxRemoteB | read-only | current | NID Series card port8 traffic overview:: Bytes Rx |
| 1.3.6.1.4.1.4756.20.502.20.1.244 | ColumnnidPort8BytesTxRemoteB | read-only | current | NID Series card port8 traffic overview:: Bytes Tx |
| 1.3.6.1.4.1.4756.20.502.20.1.245 | ColumnnidPort8ErrorsRxRemoteB | read-only | current | NID Series card port8 traffic overview:: Errors Rx |
| 1.3.6.1.4.1.4756.20.502.20.1.246 | ColumnnidPort8ErrorsTxRemoteB | read-only | current | NID Series card port8 traffic overview:: Errors Tx |
| 1.3.6.1.4.1.4756.20.502.20.1.247 | ColumnnidPort8DropsRxRemoteB | read-only | current | NID Series card port8 traffic overview:: Drops Rx |
| 1.3.6.1.4.1.4756.20.502.20.1.248 | ColumnnidPort8DropsTxRemoteB | read-only | current | NID Series card port8 traffic overview:: Drops Tx |
| 1.3.6.1.4.1.4756.20.502.20.1.249 | ColumnnidPort8FilteredRxRemoteB | read-only | current | NID Series card port8 traffic overview:: Filtered Rx |
| 1.3.6.1.4.1.4756.20.502.20.1.250 | ColumnnidAggrSourceMACAddrRemoteB | read-write | current | NID Series card Aggregation Mode Configuration: Source MAC Address 0: No 1: Yes |
| 1.3.6.1.4.1.4756.20.502.20.1.251 | ColumnnidAggrDestinationMACAddrRemoteB | read-write | current | NID Series card Aggregation Mode Configuration: Destination MAC Address 0: No 1: Yes |
| 1.3.6.1.4.1.4756.20.502.20.1.252 | ColumnnidAggrIPAddrRemoteB | read-write | current | NID Series card Aggregation Mode Configuration: IP Address 0: No 1: Yes |
| 1.3.6.1.4.1.4756.20.502.20.1.253 | ColumnnidAggrTCPUDPPortNumRemoteB | read-write | current | NID Series card Aggregation Mode Configuration: TCP/UDP Port Number 0: No 1: Yes |
| 1.3.6.1.4.1.4756.20.502.20.1.254 | ColumnnidAggrGroupPort1ConfRemoteB | read-write | current | NID Series card Aggregation Group Port1 Configuration: 0: Normal 1: ID1 2: ID2 3: ID3 4: ID4 |
| 1.3.6.1.4.1.4756.20.502.20.1.255 | ColumnnidAggrGroupPort2ConfRemoteB | read-write | current | NID Series card Aggregation Group Port2 Configuration: 0: Normal 1: ID1 2: ID2 3: ID3 4: ID4 |
| 1.3.6.1.4.1.4756.20.502.20.1.256 | ColumnnidAggrGroupPort3ConfRemoteB | read-write | current | NID Series card Aggregation Group Port3 Configuration: 0: Normal 1: ID1 2: ID2 3: ID3 4: ID4 |
| 1.3.6.1.4.1.4756.20.502.20.1.257 | ColumnnidAggrGroupPort4ConfRemoteB | read-write | current | NID Series card Aggregation Group Port4 Configuration: 0: Normal 1: ID1 2: ID2 3: ID3 4: ID4 |
| 1.3.6.1.4.1.4756.20.502.20.1.258 | ColumnnidAggrGroupPort5ConfRemoteB | read-write | current | NID Series card Aggregation Group Port5 Configuration: 0: Normal 1: ID1 2: ID2 3: ID3 4: ID4 |
| 1.3.6.1.4.1.4756.20.502.20.1.259 | ColumnnidAggrGroupPort6ConfRemoteB | read-write | current | NID Series card Aggregation Group Port6 Configuration: 0: Normal 1: ID1 2: ID2 3: ID3 4: ID4 |
| 1.3.6.1.4.1.4756.20.502.20.1.260 | ColumnnidAggrGroupPort7ConfRemoteB | read-write | current | NID Series card Aggregation Group Port7 Configuration: 0: Normal 1: ID1 2: ID2 3: ID3 4: ID4 |
| 1.3.6.1.4.1.4756.20.502.20.1.261 | ColumnnidAggrGroupPort8ConfRemoteB | read-write | current | NID Series card Aggregation Group Port8 Configuration: 0: Normal 1: ID1 2: ID2 3: ID3 4: ID4 |
| 1.3.6.1.4.1.4756.20.502.20.1.262 | ColumnnidPort1LACPEnabledRemoteB | read-write | current | NID Series card Port1 LACP Enabled: 0: No 1: Yes |
| 1.3.6.1.4.1.4756.20.502.20.1.263 | ColumnnidPort1LACPKEYRemoteB | read-write | current | NID Series card Port1 LACP Key value: The Key value incurred by the port, range 0-65535.The value of 0 means auto. |
| 1.3.6.1.4.1.4756.20.502.20.1.264 | ColumnnidPort1LACPRoleRemoteB | read-write | current | NID Series card Port1 LACP Role: 0: Passive 1: Active |
| 1.3.6.1.4.1.4756.20.502.20.1.265 | ColumnnidPort1LACPTimeOutRemoteB | read-write | current | NID Series card Port1 LACP Time out: 0: Slow 1: Fast |
| 1.3.6.1.4.1.4756.20.502.20.1.266 | ColumnnidPort1LACPPrioRemoteB | read-write | current | NID Series card Port1 LACP priority: The Key value incurred by the port, range 1-65535. |
| 1.3.6.1.4.1.4756.20.502.20.1.267 | ColumnnidPort2LACPEnabledRemoteB | read-write | current | NID Series card Port2 LACP Enabled: 0: No 1: Yes |
| 1.3.6.1.4.1.4756.20.502.20.1.268 | ColumnnidPort2LACPKEYRemoteB | read-write | current | NID Series card Port2 LACP Key value: The Key value incurred by the port, range 0-65535.The value of 0 means auto. |
| 1.3.6.1.4.1.4756.20.502.20.1.269 | ColumnnidPort2LACPRoleRemoteB | read-write | current | NID Series card Port2 LACP Role: 0: Passive 1: Active |
| 1.3.6.1.4.1.4756.20.502.20.1.270 | ColumnnidPort2LACPTimeOutRemoteB | read-write | current | NID Series card Port2 LACP Time out: 0: Slow 1: Fast |
| 1.3.6.1.4.1.4756.20.502.20.1.271 | ColumnnidPort2LACPPrioRemoteB | read-write | current | NID Series card Port2 LACP priority: The Key value incurred by the port, range 1-65535. |
| 1.3.6.1.4.1.4756.20.502.20.1.272 | ColumnnidPort3LACPEnabledRemoteB | read-write | current | NID Series card Port3 LACP Enabled: 0: No 1: Yes |
| 1.3.6.1.4.1.4756.20.502.20.1.273 | ColumnnidPort3LACPKEYRemoteB | read-write | current | NID Series card Port3 LACP Key value: The Key value incurred by the port, range 0-65535.The value of 0 means auto. |
| 1.3.6.1.4.1.4756.20.502.20.1.274 | ColumnnidPort3LACPRoleRemoteB | read-write | current | NID Series card Port3 LACP Role: 0: Passive 1: Active |
| 1.3.6.1.4.1.4756.20.502.20.1.275 | ColumnnidPort3LACPTimeOutRemoteB | read-write | current | NID Series card Port3 LACP Time out: 0: Slow 1: Fast |
| 1.3.6.1.4.1.4756.20.502.20.1.276 | ColumnnidPort3LACPPrioRemoteB | read-write | current | NID Series card Port3 LACP priority: The Key value incurred by the port, range 1-65535. |
| 1.3.6.1.4.1.4756.20.502.20.1.277 | ColumnnidPort4LACPEnabledRemoteB | read-write | current | NID Series card Port4 LACP Enabled: 0: No 1: Yes |
| 1.3.6.1.4.1.4756.20.502.20.1.278 | ColumnnidPort4LACPKEYRemoteB | read-write | current | NID Series card Port4 LACP Key value: The Key value incurred by the port, range 0-65535.The value of 0 means auto. |
| 1.3.6.1.4.1.4756.20.502.20.1.279 | ColumnnidPort4LACPRoleRemoteB | read-write | current | NID Series card Port4 LACP Role: 0: Passive 1: Active |
| 1.3.6.1.4.1.4756.20.502.20.1.280 | ColumnnidPort4LACPTimeOutRemoteB | read-write | current | NID Series card Port4 LACP Time out: 0: Slow 1: Fast |
| 1.3.6.1.4.1.4756.20.502.20.1.281 | ColumnnidPort4LACPPrioRemoteB | read-write | current | NID Series card Port4 LACP priority: The Key value incurred by the port, range 1-65535. |
| 1.3.6.1.4.1.4756.20.502.20.1.282 | ColumnnidPort5LACPEnabledRemoteB | read-write | current | NID Series card Port5 LACP Enabled: 0: No 1: Yes |
| 1.3.6.1.4.1.4756.20.502.20.1.283 | ColumnnidPort5LACPKEYRemoteB | read-write | current | NID Series card Port5 LACP Key value: The Key value incurred by the port, range 0-65535.The value of 0 means auto. |
| 1.3.6.1.4.1.4756.20.502.20.1.284 | ColumnnidPort5LACPRoleRemoteB | read-write | current | NID Series card Port5 LACP Role: 0: Passive 1: Active |
| 1.3.6.1.4.1.4756.20.502.20.1.285 | ColumnnidPort5LACPTimeOutRemoteB | read-write | current | NID Series card Port5 LACP Time out: 0: Slow 1: Fast |
| 1.3.6.1.4.1.4756.20.502.20.1.286 | ColumnnidPort5LACPPrioRemoteB | read-write | current | NID Series card Port5 LACP priority: The Key value incurred by the port, range 1-65535. |
| 1.3.6.1.4.1.4756.20.502.20.1.287 | ColumnnidPort6LACPEnabledRemoteB | read-write | current | NID Series card Port6 LACP Enabled: 0: No 1: Yes |
| 1.3.6.1.4.1.4756.20.502.20.1.288 | ColumnnidPort6LACPKEYRemoteB | read-write | current | NID Series card Port6 LACP Key value: The Key value incurred by the port, range 0-65535.The value of 0 means auto. |
| 1.3.6.1.4.1.4756.20.502.20.1.289 | ColumnnidPort6LACPRoleRemoteB | read-write | current | NID Series card Port6 LACP Role: 0: Passive 1: Active |
| 1.3.6.1.4.1.4756.20.502.20.1.290 | ColumnnidPort6LACPTimeOutRemoteB | read-write | current | NID Series card Port6 LACP Time out: 0: Slow 1: Fast |
| 1.3.6.1.4.1.4756.20.502.20.1.291 | ColumnnidPort6LACPPrioRemoteB | read-write | current | NID Series card Port6 LACP priority: The Key value incurred by the port, range 1-65535. |
| 1.3.6.1.4.1.4756.20.502.20.1.292 | ColumnnidPort7LACPEnabledRemoteB | read-write | current | NID Series card Port7 LACP Enabled: 0: No 1: Yes |
| 1.3.6.1.4.1.4756.20.502.20.1.293 | ColumnnidPort7LACPKEYRemoteB | read-write | current | NID Series card Port7 LACP Key value: The Key value incurred by the port, range 0-65535.The value of 0 means auto. |
| 1.3.6.1.4.1.4756.20.502.20.1.294 | ColumnnidPort7LACPRoleRemoteB | read-write | current | NID Series card Port7 LACP Role: 0: Passive 1: Active |
| 1.3.6.1.4.1.4756.20.502.20.1.295 | ColumnnidPort7LACPTimeOutRemoteB | read-write | current | NID Series card Port7 LACP Time out: 0: Slow 1: Fast |
| 1.3.6.1.4.1.4756.20.502.20.1.296 | ColumnnidPort7LACPPrioRemoteB | read-write | current | NID Series card Port7 LACP priority: The Key value incurred by the port, range 1-65535. |
| 1.3.6.1.4.1.4756.20.502.20.1.297 | ColumnnidPort8LACPEnabledRemoteB | read-write | current | NID Series card Port8 LACP Enabled: 0: No 1: Yes |
| 1.3.6.1.4.1.4756.20.502.20.1.298 | ColumnnidPort8LACPKEYRemoteB | read-write | current | NID Series card Port8 LACP Key value: The Key value incurred by the port, range 0-65535.The value of 0 means auto. |
| 1.3.6.1.4.1.4756.20.502.20.1.299 | ColumnnidPort8LACPRoleRemoteB | read-write | current | NID Series card Port8 LACP Role: 0: Passive 1: Active |
| 1.3.6.1.4.1.4756.20.502.20.1.300 | ColumnnidPort8LACPTimeOutRemoteB | read-write | current | NID Series card Port8 LACP Time out: 0: Slow 1: Fast |
| 1.3.6.1.4.1.4756.20.502.20.1.301 | ColumnnidPort8LACPPrioRemoteB | read-write | current | NID Series card Port8 LACP priority: The Key value incurred by the port, range 1-65535. |
| 1.3.6.1.4.1.4756.20.502.20.1.302 | ColumnnidPort1LACPstsRemoteB | read-only | current | NID Series card Port1 LACP status: 0: No 1: Yes 2: Standby |
| 1.3.6.1.4.1.4756.20.502.20.1.303 | ColumnnidPort1LACPKEYstsRemoteB | read-only | current | NID Series card Port1 LACP status: Key |
| 1.3.6.1.4.1.4756.20.502.20.1.304 | ColumnnidPort1LACPAggrIDstsRemoteB | read-only | current | NID Series card Port1 LACP status: Aggr ID |
| 1.3.6.1.4.1.4756.20.502.20.1.305 | ColumnnidPort1LACPParnterSysIDstsRemoteB | read-only | current | NID Series card Port1 LACP status: Parnter System ID |
| 1.3.6.1.4.1.4756.20.502.20.1.306 | ColumnnidPort1LACPParnterPortstsRemoteB | read-only | current | NID Series card Port1 LACP status: Parnter Port Status |
| 1.3.6.1.4.1.4756.20.502.20.1.307 | ColumnnidPort1LACPParnterProistsRemoteB | read-only | current | NID Series card Port1 LACP status: Parnter Priority |
| 1.3.6.1.4.1.4756.20.502.20.1.308 | ColumnnidPort2LACPstsRemoteB | read-only | current | NID Series card Port2 LACP status: 0: No 1: Yes 2: Standby |
| 1.3.6.1.4.1.4756.20.502.20.1.309 | ColumnnidPort2LACPKEYstsRemoteB | read-only | current | NID Series card Port2 LACP status: Key |
| 1.3.6.1.4.1.4756.20.502.20.1.310 | ColumnnidPort2LACPAggrIDstsRemoteB | read-only | current | NID Series card Port2 LACP status: Aggr ID |
| 1.3.6.1.4.1.4756.20.502.20.1.311 | ColumnnidPort2LACPParnterSysIDstsRemoteB | read-only | current | NID Series card Port2 LACP status: Parnter System ID |
| 1.3.6.1.4.1.4756.20.502.20.1.312 | ColumnnidPort2LACPParnterPortstsRemoteB | read-only | current | NID Series card Port2 LACP status: Parnter Port Status |
| 1.3.6.1.4.1.4756.20.502.20.1.313 | ColumnnidPort2LACPParnterProistsRemoteB | read-only | current | NID Series card Port2 LACP status: Parnter Priority |
| 1.3.6.1.4.1.4756.20.502.20.1.314 | ColumnnidPort3LACPstsRemoteB | read-only | current | NID Series card Port3 LACP status: 0: No 1: Yes 2: Standby |
| 1.3.6.1.4.1.4756.20.502.20.1.315 | ColumnnidPort3LACPKEYstsRemoteB | read-only | current | NID Series card Port3 LACP status: Key |
| 1.3.6.1.4.1.4756.20.502.20.1.316 | ColumnnidPort3LACPAggrIDstsRemoteB | read-only | current | NID Series card Port3 LACP status: Aggr ID |
| 1.3.6.1.4.1.4756.20.502.20.1.317 | ColumnnidPort3LACPParnterSysIDstsRemoteB | read-only | current | NID Series card Port3 LACP status: Parnter System ID |
| 1.3.6.1.4.1.4756.20.502.20.1.318 | ColumnnidPort3LACPParnterPortstsRemoteB | read-only | current | NID Series card Port3 LACP status: Parnter Port Status |
| 1.3.6.1.4.1.4756.20.502.20.1.319 | ColumnnidPort3LACPParnterProistsRemoteB | read-only | current | NID Series card Port3 LACP status: Parnter Priority |
| 1.3.6.1.4.1.4756.20.502.20.1.320 | ColumnnidPort4LACPstsRemoteB | read-only | current | NID Series card Port4 LACP status: 0: No 1: Yes 2: Standby |
| 1.3.6.1.4.1.4756.20.502.20.1.321 | ColumnnidPort4LACPKEYstsRemoteB | read-only | current | NID Series card Port4 LACP status: Key |
| 1.3.6.1.4.1.4756.20.502.20.1.322 | ColumnnidPort4LACPAggrIDstsRemoteB | read-only | current | NID Series card Port4 LACP status: Aggr ID |
| 1.3.6.1.4.1.4756.20.502.20.1.323 | ColumnnidPort4LACPParnterSysIDstsRemoteB | read-only | current | NID Series card Port4 LACP status: Parnter System ID |
| 1.3.6.1.4.1.4756.20.502.20.1.324 | ColumnnidPort4LACPParnterPortstsRemoteB | read-only | current | NID Series card Port4 LACP status: Parnter Port Status |
| 1.3.6.1.4.1.4756.20.502.20.1.325 | ColumnnidPort4LACPParnterProistsRemoteB | read-only | current | NID Series card Port4 LACP status: Parnter Priority |
| 1.3.6.1.4.1.4756.20.502.20.1.326 | ColumnnidPort5LACPstsRemoteB | read-only | current | NID Series card Port5 LACP status: 0: No 1: Yes 2: Standby |
| 1.3.6.1.4.1.4756.20.502.20.1.327 | ColumnnidPort5LACPKEYstsRemoteB | read-only | current | NID Series card Port5 LACP status: Key |
| 1.3.6.1.4.1.4756.20.502.20.1.328 | ColumnnidPort5LACPAggrIDstsRemoteB | read-only | current | NID Series card Port5 LACP status: Aggr ID |
| 1.3.6.1.4.1.4756.20.502.20.1.329 | ColumnnidPort5LACPParnterSysIDstsRemoteB | read-only | current | NID Series card Port5 LACP status: Parnter System ID |
| 1.3.6.1.4.1.4756.20.502.20.1.330 | ColumnnidPort5LACPParnterPortstsRemoteB | read-only | current | NID Series card Port5 LACP status: Parnter Port Status |
| 1.3.6.1.4.1.4756.20.502.20.1.331 | ColumnnidPort5LACPParnterProistsRemoteB | read-only | current | NID Series card Port5 LACP status: Parnter Priority |
| 1.3.6.1.4.1.4756.20.502.20.1.332 | ColumnnidPort6LACPstsRemoteB | read-only | current | NID Series card Port6 LACP status: 0: No 1: Yes 2: Standby |
| 1.3.6.1.4.1.4756.20.502.20.1.333 | ColumnnidPort6LACPKEYstsRemoteB | read-only | current | NID Series card Port6 LACP status: Key |
| 1.3.6.1.4.1.4756.20.502.20.1.334 | ColumnnidPort6LACPAggrIDstsRemoteB | read-only | current | NID Series card Port6 LACP status: Aggr ID |
| 1.3.6.1.4.1.4756.20.502.20.1.335 | ColumnnidPort6LACPParnterSysIDstsRemoteB | read-only | current | NID Series card Port6 LACP status: Parnter System ID |
| 1.3.6.1.4.1.4756.20.502.20.1.336 | ColumnnidPort6LACPParnterPortstsRemoteB | read-only | current | NID Series card Port6 LACP status: Parnter Port Status |
| 1.3.6.1.4.1.4756.20.502.20.1.337 | ColumnnidPort6LACPParnterProistsRemoteB | read-only | current | NID Series card Port6 LACP status: Parnter Priority |
| 1.3.6.1.4.1.4756.20.502.20.1.338 | ColumnnidPort7LACPstsRemoteB | read-only | current | NID Series card Port7 LACP status: 0: No 1: Yes 2: Standby |
| 1.3.6.1.4.1.4756.20.502.20.1.339 | ColumnnidPort7LACPKEYstsRemoteB | read-only | current | NID Series card Port7 LACP status: Key |
| 1.3.6.1.4.1.4756.20.502.20.1.340 | ColumnnidPort7LACPAggrIDstsRemoteB | read-only | current | NID Series card Port7 LACP status: Aggr ID |
| 1.3.6.1.4.1.4756.20.502.20.1.341 | ColumnnidPort7LACPParnterSysIDstsRemoteB | read-only | current | NID Series card Port7 LACP status: Parnter System ID |
| 1.3.6.1.4.1.4756.20.502.20.1.342 | ColumnnidPort7LACPParnterPortstsRemoteB | read-only | current | NID Series card Port7 LACP status: Parnter Port Status |
| 1.3.6.1.4.1.4756.20.502.20.1.343 | ColumnnidPort7LACPParnterProistsRemoteB | read-only | current | NID Series card Port7 LACP status: Parnter Priority |
| 1.3.6.1.4.1.4756.20.502.20.1.344 | ColumnnidPort8LACPstsRemoteB | read-only | current | NID Series card Port8 LACP status: 0: No 1: Yes 2: Standby |
| 1.3.6.1.4.1.4756.20.502.20.1.345 | ColumnnidPort8LACPKEYstsRemoteB | read-only | current | NID Series card Port8 LACP status: Key |
| 1.3.6.1.4.1.4756.20.502.20.1.346 | ColumnnidPort8LACPAggrIDstsRemoteB | read-only | current | NID Series card Port8 LACP status: Aggr ID |
| 1.3.6.1.4.1.4756.20.502.20.1.347 | ColumnnidPort8LACPParnterSysIDstsRemoteB | read-only | current | NID Series card Port8 LACP status: Parnter System ID |
| 1.3.6.1.4.1.4756.20.502.20.1.348 | ColumnnidPort8LACPParnterPortstsRemoteB | read-only | current | NID Series card Port8 LACP status: Parnter Port Status |
| 1.3.6.1.4.1.4756.20.502.20.1.349 | ColumnnidPort8LACPParnterProistsRemoteB | read-only | current | NID Series card Port8 LACP status: Parnter Priority |
| 1.3.6.1.4.1.4756.20.502.20.1.350 | ColumnnidOAMPort1EnableRemoteB | read-write | current | NID Series card Port1 OAM: 0: Off 1: On |
| 1.3.6.1.4.1.4756.20.502.20.1.351 | ColumnnidOAMPort1ModeRemoteB | read-write | current | NID Series card Port1 OAM: 0: Passive 1: Active |
| 1.3.6.1.4.1.4756.20.502.20.1.352 | ColumnnidOAMPort1LoopBackRemoteB | read-write | current | NID Series card Port1 OAM LoopBack: 0: Off 1: On |
| 1.3.6.1.4.1.4756.20.502.20.1.353 | ColumnnidOAMPort1LinkMonitorRemoteB | read-write | current | NID Series card Port1 OAM Link Monitor: 0: Off 1: On |
| 1.3.6.1.4.1.4756.20.502.20.1.354 | ColumnnidOAMPort1MIBRetrievalRemoteB | read-write | current | NID Series card Port1 OAM MIB Retrieval: 0: Off 1: On |
| 1.3.6.1.4.1.4756.20.502.20.1.355 | ColumnnidOAMPort1LoopBackOPRemoteB | read-write | current | NID Series card Port1 OAM LoopBack operation: 0: Off 1: On |
| 1.3.6.1.4.1.4756.20.502.20.1.356 | ColumnnidOAMPort2EnableRemoteB | read-write | current | NID Series card Port2 OAM: 0: Off 1: On |
| 1.3.6.1.4.1.4756.20.502.20.1.357 | ColumnnidOAMPort2ModeRemoteB | read-write | current | NID Series card Port2 OAM: 0: Passive 1: Active |
| 1.3.6.1.4.1.4756.20.502.20.1.358 | ColumnnidOAMPort2LoopBackRemoteB | read-write | current | NID Series card Port2 OAM LoopBack: 0: Off 1: On |
| 1.3.6.1.4.1.4756.20.502.20.1.359 | ColumnnidOAMPort2LinkMonitorRemoteB | read-write | current | NID Series card Port2 OAM Link Monitor: 0: Off 1: On |
| 1.3.6.1.4.1.4756.20.502.20.1.360 | ColumnnidOAMPort2MIBRetrievalRemoteB | read-write | current | NID Series card Port2 OAM MIB Retrieval: 0: Off 1: On |
| 1.3.6.1.4.1.4756.20.502.20.1.361 | ColumnnidOAMPort2LoopBackOPRemoteB | read-write | current | NID Series card Port2 OAM LoopBack operation: 0: Off 1: On |
| 1.3.6.1.4.1.4756.20.502.20.1.362 | ColumnnidOAMPort3EnableRemoteB | read-write | current | NID Series card Port3 OAM: 0: Off 1: On |
| 1.3.6.1.4.1.4756.20.502.20.1.363 | ColumnnidOAMPort3ModeRemoteB | read-write | current | NID Series card Port3 OAM: 0: Passive 1: Active |
| 1.3.6.1.4.1.4756.20.502.20.1.364 | ColumnnidOAMPort3LoopBackRemoteB | read-write | current | NID Series card Port3 OAM: 0: Off 1: On |
| 1.3.6.1.4.1.4756.20.502.20.1.365 | ColumnnidOAMPort3LinkMonitorRemoteB | read-write | current | NID Series card Port3 OAM Link Monitor: 0: Off 1: On |
| 1.3.6.1.4.1.4756.20.502.20.1.366 | ColumnnidOAMPort3MIBRetrievalRemoteB | read-write | current | NID Series card Port3 OAM MIB Retrieval: 0: Off 1: On |
| 1.3.6.1.4.1.4756.20.502.20.1.367 | ColumnnidOAMPort3LoopBackOPRemoteB | read-write | current | NID Series card Port3 OAM LoopBack operation: 0: Disable 1: Enable |
| 1.3.6.1.4.1.4756.20.502.20.1.368 | ColumnnidOAMPort4EnableRemoteB | read-write | current | NID Series card Port4 OAM: 0: Off 1: On |
| 1.3.6.1.4.1.4756.20.502.20.1.369 | ColumnnidOAMPort4ModeRemoteB | read-write | current | NID Series card Port4 OAM: 0: Passive 1: Active |
| 1.3.6.1.4.1.4756.20.502.20.1.370 | ColumnnidOAMPort4LoopBackRemoteB | read-write | current | NID Series card Port4 OAM: 0: Off 1: On |
| 1.3.6.1.4.1.4756.20.502.20.1.371 | ColumnnidOAMPort4LinkMonitorRemoteB | read-write | current | NID Series card Port4 OAM Link Monitor: 0: Off 1: On |
| 1.3.6.1.4.1.4756.20.502.20.1.372 | ColumnnidOAMPort4MIBRetrievalRemoteB | read-write | current | NID Series card Port4 OAM MIB Retrieval: 0: Off 1: On |
| 1.3.6.1.4.1.4756.20.502.20.1.373 | ColumnnidOAMPort4LoopBackOPRemoteB | read-write | current | NID Series card Port4 OAM LoopBack operation: 0: On 1: Off |
| 1.3.6.1.4.1.4756.20.502.20.1.374 | ColumnnidOAMPort5EnableRemoteB | read-write | current | NID Series card Port5 OAM: 0: Off 1: On |
| 1.3.6.1.4.1.4756.20.502.20.1.375 | ColumnnidOAMPort5ModeRemoteB | read-write | current | NID Series card Port5 OAM: 0: Passive 1: Active |
| 1.3.6.1.4.1.4756.20.502.20.1.376 | ColumnnidOAMPort5LoopBackRemoteB | read-write | current | NID Series card Port5 OAM: 0: Off 1: On |
| 1.3.6.1.4.1.4756.20.502.20.1.377 | ColumnnidOAMPort5LinkMonitorRemoteB | read-write | current | NID Series card Port5 OAM Link Monitor: 0: Off 1: On |
| 1.3.6.1.4.1.4756.20.502.20.1.378 | ColumnnidOAMPort5MIBRetrievalRemoteB | read-write | current | NID Series card Port5 OAM MIB Retrieval: 0: Off 1: On |
| 1.3.6.1.4.1.4756.20.502.20.1.379 | ColumnnidOAMPort5LoopBackOPRemoteB | read-write | current | NID Series card Port5 OAM LoopBack operation: 0: On 1: Off |
| 1.3.6.1.4.1.4756.20.502.20.1.380 | ColumnnidOAMPort6EnableRemoteB | read-write | current | NID Series card Port6 OAM: 0: Off 1: On |
| 1.3.6.1.4.1.4756.20.502.20.1.381 | ColumnnidOAMPort6ModeRemoteB | read-write | current | NID Series card Port6 OAM: 0: Passive 1: Active |
| 1.3.6.1.4.1.4756.20.502.20.1.382 | ColumnnidOAMPort6LoopBackRemoteB | read-write | current | NID Series card Port6 OAM: 0: Off 1: On |
| 1.3.6.1.4.1.4756.20.502.20.1.383 | ColumnnidOAMPort6LinkMonitorRemoteB | read-write | current | NID Series card Port6 OAM Link Monitor: 0: Off 1: On |
| 1.3.6.1.4.1.4756.20.502.20.1.384 | ColumnnidOAMPort6MIBRetrievalRemoteB | read-write | current | NID Series card Port6 OAM MIB Retrieval: 0: Off 1: On |
| 1.3.6.1.4.1.4756.20.502.20.1.385 | ColumnnidOAMPort6LoopBackOPRemoteB | read-write | current | NID Series card Port6 OAM LoopBack operation: 0: On 1: Off |
| 1.3.6.1.4.1.4756.20.502.20.1.386 | ColumnnidOAMPort7EnableRemoteB | read-write | current | NID Series card Port7 OAM: 0: Off 1: On |
| 1.3.6.1.4.1.4756.20.502.20.1.387 | ColumnnidOAMPort7ModeRemoteB | read-write | current | NID Series card Port7 OAM: 0: Passive 1: Active |
| 1.3.6.1.4.1.4756.20.502.20.1.388 | ColumnnidOAMPort7LoopBackRemoteB | read-write | current | NID Series card Port7 OAM: 0: Off 1: On |
| 1.3.6.1.4.1.4756.20.502.20.1.389 | ColumnnidOAMPort7LinkMonitorRemoteB | read-write | current | NID Series card Port7 OAM Link Monitor: 0: Off 1: On |
| 1.3.6.1.4.1.4756.20.502.20.1.390 | ColumnnidOAMPort7MIBRetrievalRemoteB | read-write | current | NID Series card Port7 OAM MIB Retrieval: 0: Off 1: On |
| 1.3.6.1.4.1.4756.20.502.20.1.391 | ColumnnidOAMPort7LoopBackOPRemoteB | read-write | current | NID Series card Port7 OAM LoopBack operation: 0: On 1: Off |
| 1.3.6.1.4.1.4756.20.502.20.1.392 | ColumnnidOAMPort8EnableRemoteB | read-write | current | NID Series card Port8 OAM: 0: Off 1: On |
| 1.3.6.1.4.1.4756.20.502.20.1.393 | ColumnnidOAMPort8ModeRemoteB | read-write | current | NID Series card Port8 OAM: 0: Passive 1: Active |
| 1.3.6.1.4.1.4756.20.502.20.1.394 | ColumnnidOAMPort8LoopBackRemoteB | read-write | current | NID Series card Port8 OAM: 0: Off 1: On |
| 1.3.6.1.4.1.4756.20.502.20.1.395 | ColumnnidOAMPort8LinkMonitorRemoteB | read-write | current | NID Series card Port8 OAM Link Monitor: 0: Off 1: On |
| 1.3.6.1.4.1.4756.20.502.20.1.396 | ColumnnidOAMPort8MIBRetrievalRemoteB | read-write | current | NID Series card Port8 OAM MIB Retrieval: 0: Off 1: On |
| 1.3.6.1.4.1.4756.20.502.20.1.397 | ColumnnidOAMPort8LoopBackOPRemoteB | read-write | current | NID Series card Port8 OAM LoopBack operation: 0: On 1: Off |
| 1.3.6.1.4.1.4756.20.502.20.1.398 | ColumnnidPort1EFEErrorWindowRemoteB | read-write | current | NID Series card Port1 Link Event Configuration: Error Frame Event - Error Window |
| 1.3.6.1.4.1.4756.20.502.20.1.399 | ColumnnidPort1EFEErrorThresholdRemoteB | read-write | current | NID Series card Port1 Link Event Configuration: Error Frame Event - Error Threshold |
| 1.3.6.1.4.1.4756.20.502.20.1.400 | ColumnnidPort1SPEEErrorWindowRemoteB | read-write | current | NID Series card Port1 Link Event Configuration: Symbol Period Error Event - Error Window |
| 1.3.6.1.4.1.4756.20.502.20.1.401 | ColumnnidPort1SPEEErrorThresholdRemoteB | read-write | current | NID Series card Port1 Link Event Configuration: Symbol Period Error Event - Error Threshold |
| 1.3.6.1.4.1.4756.20.502.20.1.402 | ColumnnidPort1SSEErrorWindowRemoteB | read-write | current | NID Series card Port1 Link Event Configuration: Seconds Summary Event - Error Window |
| 1.3.6.1.4.1.4756.20.502.20.1.403 | ColumnnidPort1SSEErrorThresholdRemoteB | read-write | current | NID Series card Port1 Link Event Configuration: Seconds Summary Event - Error Threshold |
| 1.3.6.1.4.1.4756.20.502.20.1.404 | ColumnnidPort2EFEErrorWindowRemoteB | read-write | current | NID Series card Port2 Link Event Configuration: Error Frame Event - Error Window |
| 1.3.6.1.4.1.4756.20.502.20.1.405 | ColumnnidPort2EFEErrorThresholdRemoteB | read-write | current | NID Series card Port2 Link Event Configuration: Error Frame Event - Error Threshold |
| 1.3.6.1.4.1.4756.20.502.20.1.406 | ColumnnidPort2SPEEErrorWindowRemoteB | read-write | current | NID Series card Port2 Link Event Configuration: Symbol Period Error Event - Error Window |
| 1.3.6.1.4.1.4756.20.502.20.1.407 | ColumnnidPort2SPEEErrorThresholdRemoteB | read-write | current | NID Series card Port2 Link Event Configuration: Symbol Period Error Event - Error Threshold |
| 1.3.6.1.4.1.4756.20.502.20.1.408 | ColumnnidPort2SSEErrorWindowRemoteB | read-write | current | NID Series card Port2 Link Event Configuration: Seconds Summary Event - Error Window |
| 1.3.6.1.4.1.4756.20.502.20.1.409 | ColumnnidPort2SSEErrorThresholdRemoteB | read-write | current | NID Series card Port2 Link Event Configuration: Seconds Summary Event - Error Threshold |
| 1.3.6.1.4.1.4756.20.502.20.1.410 | ColumnnidPort3EFEErrorWindowRemoteB | read-write | current | NID Series card Port3 Link Event Configuration: Error Frame Event - Error Window |
| 1.3.6.1.4.1.4756.20.502.20.1.411 | ColumnnidPort3EFEErrorThresholdRemoteB | read-write | current | NID Series card Port3 Link Event Configuration: Error Frame Event - Error Threshold |
| 1.3.6.1.4.1.4756.20.502.20.1.412 | ColumnnidPort3SPEEErrorWindowRemoteB | read-write | current | NID Series card Port3 Link Event Configuration: Symbol Period Error Event - Error Window |
| 1.3.6.1.4.1.4756.20.502.20.1.413 | ColumnnidPort3SPEEErrorThresholdRemoteB | read-write | current | NID Series card Port3 Link Event Configuration: Symbol Period Error Event - Error Threshold |
| 1.3.6.1.4.1.4756.20.502.20.1.414 | ColumnnidPort3SSEErrorWindowRemoteB | read-write | current | NID Series card Port3 Link Event Configuration: Seconds Summary Event - Error Window |
| 1.3.6.1.4.1.4756.20.502.20.1.415 | ColumnnidPort3SSEErrorThresholdRemoteB | read-write | current | NID Series card Port3 Link Event Configuration: Seconds Summary Event - Error Threshold |
| 1.3.6.1.4.1.4756.20.502.20.1.416 | ColumnnidPort4EFEErrorWindowRemoteB | read-write | current | NID Series card Port4 Link Event Configuration: Error Frame Event - Error Window |
| 1.3.6.1.4.1.4756.20.502.20.1.417 | ColumnnidPort4EFEErrorThresholdRemoteB | read-write | current | NID Series card Port4 Link Event Configuration: Error Frame Event - Error Threshold |
| 1.3.6.1.4.1.4756.20.502.20.1.418 | ColumnnidPort4SPEEErrorWindowRemoteB | read-write | current | NID Series card Port4 Link Event Configuration: Symbol Period Error Event - Error Window |
| 1.3.6.1.4.1.4756.20.502.20.1.419 | ColumnnidPort4SPEEErrorThresholdRemoteB | read-write | current | NID Series card Port4 Link Event Configuration: Symbol Period Error Event - Error Threshold |
| 1.3.6.1.4.1.4756.20.502.20.1.420 | ColumnnidPort4SSEErrorWindowRemoteB | read-write | current | NID Series card Port4 Link Event Configuration: Seconds Summary Event - Error Window |
| 1.3.6.1.4.1.4756.20.502.20.1.421 | ColumnnidPort4SSEErrorThresholdRemoteB | read-write | current | NID Series card Port4 Link Event Configuration: Seconds Summary Event - Error Threshold |
| 1.3.6.1.4.1.4756.20.502.20.1.422 | ColumnnidPort5EFEErrorWindowRemoteB | read-write | current | NID Series card Port5 Link Event Configuration: Error Frame Event - Error Window |
| 1.3.6.1.4.1.4756.20.502.20.1.423 | ColumnnidPort5EFEErrorThresholdRemoteB | read-write | current | NID Series card Port5 Link Event Configuration: Error Frame Event - Error Threshold |
| 1.3.6.1.4.1.4756.20.502.20.1.424 | ColumnnidPort5SPEEErrorWindowRemoteB | read-write | current | NID Series card Port5 Link Event Configuration: Symbol Period Error Event - Error Window |
| 1.3.6.1.4.1.4756.20.502.20.1.425 | ColumnnidPort5SPEEErrorThresholdRemoteB | read-write | current | NID Series card Port5 Link Event Configuration: Symbol Period Error Event - Error Threshold |
| 1.3.6.1.4.1.4756.20.502.20.1.426 | ColumnnidPort5SSEErrorWindowRemoteB | read-write | current | NID Series card Port5 Link Event Configuration: Seconds Summary Event - Error Window |
| 1.3.6.1.4.1.4756.20.502.20.1.427 | ColumnnidPort5SSEErrorThresholdRemoteB | read-write | current | NID Series card Port5 Link Event Configuration: Seconds Summary Event - Error Threshold |
| 1.3.6.1.4.1.4756.20.502.20.1.428 | ColumnnidPort6EFEErrorWindowRemoteB | read-write | current | NID Series card Port6 Link Event Configuration: Error Frame Event - Error Window |
| 1.3.6.1.4.1.4756.20.502.20.1.429 | ColumnnidPort6EFEErrorThresholdRemoteB | read-write | current | NID Series card Port6 Link Event Configuration: Error Frame Event - Error Threshold |
| 1.3.6.1.4.1.4756.20.502.20.1.430 | ColumnnidPort6SPEEErrorWindowRemoteB | read-write | current | NID Series card Port6 Link Event Configuration: Symbol Period Error Event - Error Window |
| 1.3.6.1.4.1.4756.20.502.20.1.431 | ColumnnidPort6SPEEErrorThresholdRemoteB | read-write | current | NID Series card Port6 Link Event Configuration: Symbol Period Error Event - Error Threshold |
| 1.3.6.1.4.1.4756.20.502.20.1.432 | ColumnnidPort6SSEErrorWindowRemoteB | read-write | current | NID Series card Port6 Link Event Configuration: Seconds Summary Event - Error Window |
| 1.3.6.1.4.1.4756.20.502.20.1.433 | ColumnnidPort6SSEErrorThresholdRemoteB | read-write | current | NID Series card Port6 Link Event Configuration: Seconds Summary Event - Error Threshold |
| 1.3.6.1.4.1.4756.20.502.20.1.434 | ColumnnidPort7EFEErrorWindowRemoteB | read-write | current | NID Series card Port7 Link Event Configuration: Error Frame Event - Error Window |
| 1.3.6.1.4.1.4756.20.502.20.1.435 | ColumnnidPort7EFEErrorThresholdRemoteB | read-write | current | NID Series card Port7 Link Event Configuration: Error Frame Event - Error Threshold |
| 1.3.6.1.4.1.4756.20.502.20.1.436 | ColumnnidPort7SPEEErrorWindowRemoteB | read-write | current | NID Series card Port7 Link Event Configuration: Symbol Period Error Event - Error Window |
| 1.3.6.1.4.1.4756.20.502.20.1.437 | ColumnnidPort7SPEEErrorThresholdRemoteB | read-write | current | NID Series card Port7 Link Event Configuration: Symbol Period Error Event - Error Threshold |
| 1.3.6.1.4.1.4756.20.502.20.1.438 | ColumnnidPort7SSEErrorWindowRemoteB | read-write | current | NID Series card Port7 Link Event Configuration: Seconds Summary Event - Error Window |
| 1.3.6.1.4.1.4756.20.502.20.1.439 | ColumnnidPort7SSEErrorThresholdRemoteB | read-write | current | NID Series card Port7 Link Event Configuration: Seconds Summary Event - Error Threshold |
| 1.3.6.1.4.1.4756.20.502.20.1.440 | ColumnnidPort8EFEErrorWindowRemoteB | read-write | current | NID Series card Port8 Link Event Configuration: Error Frame Event - Error Window |
| 1.3.6.1.4.1.4756.20.502.20.1.441 | ColumnnidPort8EFEErrorThresholdRemoteB | read-write | current | NID Series card Port8 Link Event Configuration: Error Frame Event - Error Threshold |
| 1.3.6.1.4.1.4756.20.502.20.1.442 | ColumnnidPort8SPEEErrorWindowRemoteB | read-write | current | NID Series card Port8 Link Event Configuration: Symbol Period Error Event - Error Window |
| 1.3.6.1.4.1.4756.20.502.20.1.443 | ColumnnidPort8SPEEErrorThresholdRemoteB | read-write | current | NID Series card Port8 Link Event Configuration: Symbol Period Error Event - Error Threshold |
| 1.3.6.1.4.1.4756.20.502.20.1.444 | ColumnnidPort8SSEErrorWindowRemoteB | read-write | current | NID Series card Port8 Link Event Configuration: Seconds Summary Event - Error Window |
| 1.3.6.1.4.1.4756.20.502.20.1.445 | ColumnnidPort8SSEErrorThresholdRemoteB | read-write | current | NID Series card Port8 Link Event Configuration: Seconds Summary Event - Error Threshold |
| 1.3.6.1.4.1.4756.20.502.20.1.446 | ColumnnidPort1RxOAMInfoPDURemoteB | read-only | current | NID Series card Port1 Detailed Link OAM Statistics: Rx OAM Information PDU's |
| 1.3.6.1.4.1.4756.20.502.20.1.447 | ColumnnidPort1RxUniqueErrorEventRemoteB | read-only | current | NID Series card Port1 Detailed Link OAM Statistics: Rx Unique Error Event Notificatio |
| 1.3.6.1.4.1.4756.20.502.20.1.448 | ColumnnidPort1RxDuplicateErrorEventRemoteB | read-only | current | NID Series card Port1 Detailed Link OAM Statistics: Rx Duplicate Error Event Notification |
| 1.3.6.1.4.1.4756.20.502.20.1.449 | ColumnnidPort1RxLoopBackControlRemoteB | read-only | current | NID Series card Port1 Detailed Link OAM Statistics: Rx Loopback Control |
| 1.3.6.1.4.1.4756.20.502.20.1.450 | ColumnnidPort1RxVariableRequestRemoteB | read-only | current | NID Series card Port1 Detailed Link OAM Statistics: Rx Variable Request |
| 1.3.6.1.4.1.4756.20.502.20.1.451 | ColumnnidPort1RxVariableResponseRemoteB | read-only | current | NID Series card Port1 Detailed Link OAM Statistics: Rx Variable Response |
| 1.3.6.1.4.1.4756.20.502.20.1.452 | ColumnnidPort1RxOrgSpecificPDURemoteB | read-only | current | NID Series card Port1 Detailed Link OAM Statistics: Rx Org Specific PDU's |
| 1.3.6.1.4.1.4756.20.502.20.1.453 | ColumnnidPort1RxUnsupportedCodesRemoteB | read-only | current | NID Series card Port1 Detailed Link OAM Statistics: Rx Unsupported Codes |
| 1.3.6.1.4.1.4756.20.502.20.1.454 | ColumnnidPort1RxLinkFaultPDURemoteB | read-only | current | NID Series card Port1 Detailed Link OAM Statistics: Rx Link Fault PDU's |
| 1.3.6.1.4.1.4756.20.502.20.1.455 | ColumnnidPort1RxDyingGaspRemoteB | read-only | current | NID Series card Port1 Detailed Link OAM Statistics: Rx Dying Gasp |
| 1.3.6.1.4.1.4756.20.502.20.1.456 | ColumnnidPort1RxCriticalEventPDURemoteB | read-only | current | NID Series card Port1 Detailed Link OAM Statistics: Rx Dying Gasp |
| 1.3.6.1.4.1.4756.20.502.20.1.457 | ColumnnidPort1TxOAMInfoPDURemoteB | read-only | current | NID Series card Port1 Detailed Link OAM Statistics: Tx OAM Information PDU's |
| 1.3.6.1.4.1.4756.20.502.20.1.458 | ColumnnidPort1TxUniqueErrorEventRemoteB | read-only | current | NID Series card Port1 Detailed Link OAM Statistics: Tx Unique Error Event Notificatio |
| 1.3.6.1.4.1.4756.20.502.20.1.459 | ColumnnidPort1TxDuplicateErrorEventRemoteB | read-only | current | NID Series card Port1 Detailed Link OAM Statistics: Tx Duplicate Error Event Notification |
| 1.3.6.1.4.1.4756.20.502.20.1.460 | ColumnnidPort1TxLoopBackControlRemoteB | read-only | current | NID Series card Port1 Detailed Link OAM Statistics: Tx Loopback Control |
| 1.3.6.1.4.1.4756.20.502.20.1.461 | ColumnnidPort1TxVariableRequestRemoteB | read-only | current | NID Series card Port1 Detailed Link OAM Statistics: Tx Variable Request |
| 1.3.6.1.4.1.4756.20.502.20.1.462 | ColumnnidPort1TxVariableResponseRemoteB | read-only | current | NID Series card Port1 Detailed Link OAM Statistics: Tx Variable Response |
| 1.3.6.1.4.1.4756.20.502.20.1.463 | ColumnnidPort1TxOrgSpecificPDURemoteB | read-only | current | NID Series card Port1 Detailed Link OAM Statistics: Tx Org Specific PDU's |
| 1.3.6.1.4.1.4756.20.502.20.1.464 | ColumnnidPort1TxUnsupportedCodesRemoteB | read-only | current | NID Series card Port1 Detailed Link OAM Statistics: Tx Unsupported Codes |
| 1.3.6.1.4.1.4756.20.502.20.1.465 | ColumnnidPort1TxLinkFaultPDURemoteB | read-only | current | NID Series card Port1 Detailed Link OAM Statistics: Tx Link Fault PDU's |
| 1.3.6.1.4.1.4756.20.502.20.1.466 | ColumnnidPort1TxDyingGaspRemoteB | read-only | current | NID Series card Port1 Detailed Link OAM Statistics: Tx Dying Gasp |
| 1.3.6.1.4.1.4756.20.502.20.1.467 | ColumnnidPort1TxCriticalEventPDURemoteB | read-only | current | NID Series card Port1 Detailed Link OAM Statistics: Tx Dying Gasp |
| 1.3.6.1.4.1.4756.20.502.20.1.468 | ColumnnidPort2RxOAMInfoPDURemoteB | read-only | current | NID Series card Port2 Detailed Link OAM Statistics: Rx OAM Information PDU's |
| 1.3.6.1.4.1.4756.20.502.20.1.469 | ColumnnidPort2RxUniqueErrorEventRemoteB | read-only | current | NID Series card Port2 Detailed Link OAM Statistics: Rx Unique Error Event Notificatio |
| 1.3.6.1.4.1.4756.20.502.20.1.470 | ColumnnidPort2RxDuplicateErrorEventRemoteB | read-only | current | NID Series card Port2 Detailed Link OAM Statistics: Rx Duplicate Error Event Notification |
| 1.3.6.1.4.1.4756.20.502.20.1.471 | ColumnnidPort2RxLoopBackControlRemoteB | read-only | current | NID Series card Port2 Detailed Link OAM Statistics: Rx Loopback Control |
| 1.3.6.1.4.1.4756.20.502.20.1.472 | ColumnnidPort2RxVariableRequestRemoteB | read-only | current | NID Series card Port2 Detailed Link OAM Statistics: Rx Variable Request |
| 1.3.6.1.4.1.4756.20.502.20.1.473 | ColumnnidPort2RxVariableResponseRemoteB | read-only | current | NID Series card Port2 Detailed Link OAM Statistics: Rx Variable Response |
| 1.3.6.1.4.1.4756.20.502.20.1.474 | ColumnnidPort2RxOrgSpecificPDURemoteB | read-only | current | NID Series card Port2 Detailed Link OAM Statistics: Rx Org Specific PDU's |
| 1.3.6.1.4.1.4756.20.502.20.1.475 | ColumnnidPort2RxUnsupportedCodesRemoteB | read-only | current | NID Series card Port2 Detailed Link OAM Statistics: Rx Unsupported Codes |
| 1.3.6.1.4.1.4756.20.502.20.1.476 | ColumnnidPort2RxLinkFaultPDURemoteB | read-only | current | NID Series card Port2 Detailed Link OAM Statistics: Rx Link Fault PDU's |
| 1.3.6.1.4.1.4756.20.502.20.1.477 | ColumnnidPort2RxDyingGaspRemoteB | read-only | current | NID Series card Port2 Detailed Link OAM Statistics: Rx Dying Gasp |
| 1.3.6.1.4.1.4756.20.502.20.1.478 | ColumnnidPort2RxCriticalEventPDURemoteB | read-only | current | NID Series card Port2 Detailed Link OAM Statistics: Rx Dying Gasp |
| 1.3.6.1.4.1.4756.20.502.20.1.479 | ColumnnidPort2TxOAMInfoPDURemoteB | read-only | current | NID Series card Port2 Detailed Link OAM Statistics: Tx OAM Information PDU's |
| 1.3.6.1.4.1.4756.20.502.20.1.480 | ColumnnidPort2TxUniqueErrorEventRemoteB | read-only | current | NID Series card Port2 Detailed Link OAM Statistics: Tx Unique Error Event Notificatio |
| 1.3.6.1.4.1.4756.20.502.20.1.481 | ColumnnidPort2TxDuplicateErrorEventRemoteB | read-only | current | NID Series card Port2 Detailed Link OAM Statistics: Tx Duplicate Error Event Notification |
| 1.3.6.1.4.1.4756.20.502.20.1.482 | ColumnnidPort2TxLoopBackControlRemoteB | read-only | current | NID Series card Port2 Detailed Link OAM Statistics: Tx Loopback Control |
| 1.3.6.1.4.1.4756.20.502.20.1.483 | ColumnnidPort2TxVariableRequestRemoteB | read-only | current | NID Series card Port2 Detailed Link OAM Statistics: Tx Variable Request |
| 1.3.6.1.4.1.4756.20.502.20.1.484 | ColumnnidPort2TxVariableResponseRemoteB | read-only | current | NID Series card Port2 Detailed Link OAM Statistics: Tx Variable Response |
| 1.3.6.1.4.1.4756.20.502.20.1.485 | ColumnnidPort2TxOrgSpecificPDURemoteB | read-only | current | NID Series card Port2 Detailed Link OAM Statistics: Tx Org Specific PDU's |
| 1.3.6.1.4.1.4756.20.502.20.1.486 | ColumnnidPort2TxUnsupportedCodesRemoteB | read-only | current | NID Series card Port2 Detailed Link OAM Statistics: Tx Unsupported Codes |
| 1.3.6.1.4.1.4756.20.502.20.1.487 | ColumnnidPort2TxLinkFaultPDURemoteB | read-only | current | NID Series card Port2 Detailed Link OAM Statistics: Tx Link Fault PDU's |
| 1.3.6.1.4.1.4756.20.502.20.1.488 | ColumnnidPort2TxDyingGaspRemoteB | read-only | current | NID Series card Port2 Detailed Link OAM Statistics: Tx Dying Gasp |
| 1.3.6.1.4.1.4756.20.502.20.1.489 | ColumnnidPort2TxCriticalEventPDURemoteB | read-only | current | NID Series card Port2 Detailed Link OAM Statistics: Tx Dying Gasp |
| 1.3.6.1.4.1.4756.20.502.20.1.490 | ColumnnidPort3RxOAMInfoPDURemoteB | read-only | current | NID Series card Port3 Detailed Link OAM Statistics: Rx OAM Information PDU's |
| 1.3.6.1.4.1.4756.20.502.20.1.491 | ColumnnidPort3RxUniqueErrorEventRemoteB | read-only | current | NID Series card Port3 Detailed Link OAM Statistics: Rx Unique Error Event Notificatio |
| 1.3.6.1.4.1.4756.20.502.20.1.492 | ColumnnidPort3RxDuplicateErrorEventRemoteB | read-only | current | NID Series card Port3 Detailed Link OAM Statistics: Rx Duplicate Error Event Notification |
| 1.3.6.1.4.1.4756.20.502.20.1.493 | ColumnnidPort3RxLoopBackControlRemoteB | read-only | current | NID Series card Port3 Detailed Link OAM Statistics: Rx Loopback Control |
| 1.3.6.1.4.1.4756.20.502.20.1.494 | ColumnnidPort3RxVariableRequestRemoteB | read-only | current | NID Series card Port3 Detailed Link OAM Statistics: Rx Variable Request |
| 1.3.6.1.4.1.4756.20.502.20.1.495 | ColumnnidPort3RxVariableResponseRemoteB | read-only | current | NID Series card Port3 Detailed Link OAM Statistics: Rx Variable Response |
| 1.3.6.1.4.1.4756.20.502.20.1.496 | ColumnnidPort3RxOrgSpecificPDURemoteB | read-only | current | NID Series card Port3 Detailed Link OAM Statistics: Rx Org Specific PDU's |
| 1.3.6.1.4.1.4756.20.502.20.1.497 | ColumnnidPort3RxUnsupportedCodesRemoteB | read-only | current | NID Series card Port3 Detailed Link OAM Statistics: Rx Unsupported Codes |
| 1.3.6.1.4.1.4756.20.502.20.1.498 | ColumnnidPort3RxLinkFaultPDURemoteB | read-only | current | NID Series card Port3 Detailed Link OAM Statistics: Rx Link Fault PDU's |
| 1.3.6.1.4.1.4756.20.502.20.1.499 | ColumnnidPort3RxDyingGaspRemoteB | read-only | current | NID Series card Port3 Detailed Link OAM Statistics: Rx Dying Gasp |
| 1.3.6.1.4.1.4756.20.502.20.1.500 | ColumnnidPort3RxCriticalEventPDURemoteB | read-only | current | NID Series card Port3 Detailed Link OAM Statistics: Rx Dying Gasp |
| 1.3.6.1.4.1.4756.20.502.20.1.501 | ColumnnidPort3TxOAMInfoPDURemoteB | read-only | current | NID Series card Port3 Detailed Link OAM Statistics: Tx OAM Information PDU's |
| 1.3.6.1.4.1.4756.20.502.20.1.502 | ColumnnidPort3TxUniqueErrorEventRemoteB | read-only | current | NID Series card Port3 Detailed Link OAM Statistics: Tx Unique Error Event Notificatio |
| 1.3.6.1.4.1.4756.20.502.20.1.503 | ColumnnidPort3TxDuplicateErrorEventRemoteB | read-only | current | NID Series card Port3 Detailed Link OAM Statistics: Tx Duplicate Error Event Notification |
| 1.3.6.1.4.1.4756.20.502.20.1.504 | ColumnnidPort3TxLoopBackControlRemoteB | read-only | current | NID Series card Port3 Detailed Link OAM Statistics: Tx Loopback Control |
| 1.3.6.1.4.1.4756.20.502.20.1.505 | ColumnnidPort3TxVariableRequestRemoteB | read-only | current | NID Series card Port3 Detailed Link OAM Statistics: Tx Variable Request |
| 1.3.6.1.4.1.4756.20.502.20.1.506 | ColumnnidPort3TxVariableResponseRemoteB | read-only | current | NID Series card Port3 Detailed Link OAM Statistics: Tx Variable Response |
| 1.3.6.1.4.1.4756.20.502.20.1.507 | ColumnnidPort3TxOrgSpecificPDURemoteB | read-only | current | NID Series card Port3 Detailed Link OAM Statistics: Tx Org Specific PDU's |
| 1.3.6.1.4.1.4756.20.502.20.1.508 | ColumnnidPort3TxUnsupportedCodesRemoteB | read-only | current | NID Series card Port3 Detailed Link OAM Statistics: Tx Unsupported Codes |
| 1.3.6.1.4.1.4756.20.502.20.1.509 | ColumnnidPort3TxLinkFaultPDURemoteB | read-only | current | NID Series card Port3 Detailed Link OAM Statistics: Tx Link Fault PDU's |
| 1.3.6.1.4.1.4756.20.502.20.1.510 | ColumnnidPort3TxDyingGaspRemoteB | read-only | current | NID Series card Port3 Detailed Link OAM Statistics: Tx Dying Gasp |
| 1.3.6.1.4.1.4756.20.502.20.1.511 | ColumnnidPort3TxCriticalEventPDURemoteB | read-only | current | NID Series card Port3 Detailed Link OAM Statistics: Tx Dying Gasp |
| 1.3.6.1.4.1.4756.20.502.20.1.512 | ColumnnidPort4RxOAMInfoPDURemoteB | read-only | current | NID Series card Port4 Detailed Link OAM Statistics: Rx OAM Information PDU's |
| 1.3.6.1.4.1.4756.20.502.20.1.513 | ColumnnidPort4RxUniqueErrorEventRemoteB | read-only | current | NID Series card Port4 Detailed Link OAM Statistics: Rx Unique Error Event Notificatio |
| 1.3.6.1.4.1.4756.20.502.20.1.514 | ColumnnidPort4RxDuplicateErrorEventRemoteB | read-only | current | NID Series card Port4 Detailed Link OAM Statistics: Rx Duplicate Error Event Notification |
| 1.3.6.1.4.1.4756.20.502.20.1.515 | ColumnnidPort4RxLoopBackControlRemoteB | read-only | current | NID Series card Port4 Detailed Link OAM Statistics: Rx Loopback Control |
| 1.3.6.1.4.1.4756.20.502.20.1.516 | ColumnnidPort4RxVariableRequestRemoteB | read-only | current | NID Series card Port4 Detailed Link OAM Statistics: Rx Variable Request |
| 1.3.6.1.4.1.4756.20.502.20.1.517 | ColumnnidPort4RxVariableResponseRemoteB | read-only | current | NID Series card Port4 Detailed Link OAM Statistics: Rx Variable Response |
| 1.3.6.1.4.1.4756.20.502.20.1.518 | ColumnnidPort4RxOrgSpecificPDURemoteB | read-only | current | NID Series card Port4 Detailed Link OAM Statistics: Rx Org Specific PDU's |
| 1.3.6.1.4.1.4756.20.502.20.1.519 | ColumnnidPort4RxUnsupportedCodesRemoteB | read-only | current | NID Series card Port4 Detailed Link OAM Statistics: Rx Unsupported Codes |
| 1.3.6.1.4.1.4756.20.502.20.1.520 | ColumnnidPort4RxLinkFaultPDURemoteB | read-only | current | NID Series card Port4 Detailed Link OAM Statistics: Rx Link Fault PDU's |
| 1.3.6.1.4.1.4756.20.502.20.1.521 | ColumnnidPort4RxDyingGaspRemoteB | read-only | current | NID Series card Port4 Detailed Link OAM Statistics: Rx Dying Gasp |
| 1.3.6.1.4.1.4756.20.502.20.1.522 | ColumnnidPort4RxCriticalEventPDURemoteB | read-only | current | NID Series card Port4 Detailed Link OAM Statistics: Rx Dying Gasp |
| 1.3.6.1.4.1.4756.20.502.20.1.523 | ColumnnidPort4TxOAMInfoPDURemoteB | read-only | current | NID Series card Port4 Detailed Link OAM Statistics: Tx OAM Information PDU's |
| 1.3.6.1.4.1.4756.20.502.20.1.524 | ColumnnidPort4TxUniqueErrorEventRemoteB | read-only | current | NID Series card Port4 Detailed Link OAM Statistics: Tx Unique Error Event Notificatio |
| 1.3.6.1.4.1.4756.20.502.20.1.525 | ColumnnidPort4TxDuplicateErrorEventRemoteB | read-only | current | NID Series card Port4 Detailed Link OAM Statistics: Tx Duplicate Error Event Notification |
| 1.3.6.1.4.1.4756.20.502.20.1.526 | ColumnnidPort4TxLoopBackControlRemoteB | read-only | current | NID Series card Port4 Detailed Link OAM Statistics: Tx Loopback Control |
| 1.3.6.1.4.1.4756.20.502.20.1.527 | ColumnnidPort4TxVariableRequestRemoteB | read-only | current | NID Series card Port4 Detailed Link OAM Statistics: Tx Variable Request |
| 1.3.6.1.4.1.4756.20.502.20.1.528 | ColumnnidPort4TxVariableResponseRemoteB | read-only | current | NID Series card Port4 Detailed Link OAM Statistics: Tx Variable Response |
| 1.3.6.1.4.1.4756.20.502.20.1.529 | ColumnnidPort4TxOrgSpecificPDURemoteB | read-only | current | NID Series card Port4 Detailed Link OAM Statistics: Tx Org Specific PDU's |
| 1.3.6.1.4.1.4756.20.502.20.1.530 | ColumnnidPort4TxUnsupportedCodesRemoteB | read-only | current | NID Series card Port4 Detailed Link OAM Statistics: Tx Unsupported Codes |
| 1.3.6.1.4.1.4756.20.502.20.1.531 | ColumnnidPort4TxLinkFaultPDURemoteB | read-only | current | NID Series card Port4 Detailed Link OAM Statistics: Tx Link Fault PDU's |
| 1.3.6.1.4.1.4756.20.502.20.1.532 | ColumnnidPort4TxDyingGaspRemoteB | read-only | current | NID Series card Port4 Detailed Link OAM Statistics: Tx Dying Gasp |
| 1.3.6.1.4.1.4756.20.502.20.1.533 | ColumnnidPort4TxCriticalEventPDURemoteB | read-only | current | NID Series card Port4 Detailed Link OAM Statistics: Tx Dying Gasp |
| 1.3.6.1.4.1.4756.20.502.20.1.534 | ColumnnidPort5RxOAMInfoPDURemoteB | read-only | current | NID Series card Port5 Detailed Link OAM Statistics: Rx OAM Information PDU's |
| 1.3.6.1.4.1.4756.20.502.20.1.535 | ColumnnidPort5RxUniqueErrorEventRemoteB | read-only | current | NID Series card Port5 Detailed Link OAM Statistics: Rx Unique Error Event Notificatio |
| 1.3.6.1.4.1.4756.20.502.20.1.536 | ColumnnidPort5RxDuplicateErrorEventRemoteB | read-only | current | NID Series card Port5 Detailed Link OAM Statistics: Rx Duplicate Error Event Notification |
| 1.3.6.1.4.1.4756.20.502.20.1.537 | ColumnnidPort5RxLoopBackControlRemoteB | read-only | current | NID Series card Port5 Detailed Link OAM Statistics: Rx Loopback Control |
| 1.3.6.1.4.1.4756.20.502.20.1.538 | ColumnnidPort5RxVariableRequestRemoteB | read-only | current | NID Series card Port5 Detailed Link OAM Statistics: Rx Variable Request |
| 1.3.6.1.4.1.4756.20.502.20.1.539 | ColumnnidPort5RxVariableResponseRemoteB | read-only | current | NID Series card Port5 Detailed Link OAM Statistics: Rx Variable Response |
| 1.3.6.1.4.1.4756.20.502.20.1.540 | ColumnnidPort5RxOrgSpecificPDURemoteB | read-only | current | NID Series card Port5 Detailed Link OAM Statistics: Rx Org Specific PDU's |
| 1.3.6.1.4.1.4756.20.502.20.1.541 | ColumnnidPort5RxUnsupportedCodesRemoteB | read-only | current | NID Series card Port5 Detailed Link OAM Statistics: Rx Unsupported Codes |
| 1.3.6.1.4.1.4756.20.502.20.1.542 | ColumnnidPort5RxLinkFaultPDURemoteB | read-only | current | NID Series card Port5 Detailed Link OAM Statistics: Rx Link Fault PDU's |
| 1.3.6.1.4.1.4756.20.502.20.1.543 | ColumnnidPort5RxDyingGaspRemoteB | read-only | current | NID Series card Port5 Detailed Link OAM Statistics: Rx Dying Gasp |
| 1.3.6.1.4.1.4756.20.502.20.1.544 | ColumnnidPort5RxCriticalEventPDURemoteB | read-only | current | NID Series card Port5 Detailed Link OAM Statistics: Rx Dying Gasp |
| 1.3.6.1.4.1.4756.20.502.20.1.545 | ColumnnidPort5TxOAMInfoPDURemoteB | read-only | current | NID Series card Port5 Detailed Link OAM Statistics: Tx OAM Information PDU's |
| 1.3.6.1.4.1.4756.20.502.20.1.546 | ColumnnidPort5TxUniqueErrorEventRemoteB | read-only | current | NID Series card Port5 Detailed Link OAM Statistics: Tx Unique Error Event Notificatio |
| 1.3.6.1.4.1.4756.20.502.20.1.547 | ColumnnidPort5TxDuplicateErrorEventRemoteB | read-only | current | NID Series card Port5 Detailed Link OAM Statistics: Tx Duplicate Error Event Notification |
| 1.3.6.1.4.1.4756.20.502.20.1.548 | ColumnnidPort5TxLoopBackControlRemoteB | read-only | current | NID Series card Port5 Detailed Link OAM Statistics: Tx Loopback Control |
| 1.3.6.1.4.1.4756.20.502.20.1.549 | ColumnnidPort5TxVariableRequestRemoteB | read-only | current | NID Series card Port5 Detailed Link OAM Statistics: Tx Variable Request |
| 1.3.6.1.4.1.4756.20.502.20.1.550 | ColumnnidPort5TxVariableResponseRemoteB | read-only | current | NID Series card Port5 Detailed Link OAM Statistics: Tx Variable Response |
| 1.3.6.1.4.1.4756.20.502.20.1.551 | ColumnnidPort5TxOrgSpecificPDURemoteB | read-only | current | NID Series card Port5 Detailed Link OAM Statistics: Tx Org Specific PDU's |
| 1.3.6.1.4.1.4756.20.502.20.1.552 | ColumnnidPort5TxUnsupportedCodesRemoteB | read-only | current | NID Series card Port5 Detailed Link OAM Statistics: Tx Unsupported Codes |
| 1.3.6.1.4.1.4756.20.502.20.1.553 | ColumnnidPort5TxLinkFaultPDURemoteB | read-only | current | NID Series card Port5 Detailed Link OAM Statistics: Tx Link Fault PDU's |
| 1.3.6.1.4.1.4756.20.502.20.1.554 | ColumnnidPort5TxDyingGaspRemoteB | read-only | current | NID Series card Port5 Detailed Link OAM Statistics: Tx Dying Gasp |
| 1.3.6.1.4.1.4756.20.502.20.1.555 | ColumnnidPort5TxCriticalEventPDURemoteB | read-only | current | NID Series card Port5 Detailed Link OAM Statistics: Tx Dying Gasp |
| 1.3.6.1.4.1.4756.20.502.20.1.556 | ColumnnidPort6RxOAMInfoPDURemoteB | read-only | current | NID Series card Port6 Detailed Link OAM Statistics: Rx OAM Information PDU's |
| 1.3.6.1.4.1.4756.20.502.20.1.557 | ColumnnidPort6RxUniqueErrorEventRemoteB | read-only | current | NID Series card Port6 Detailed Link OAM Statistics: Rx Unique Error Event Notificatio |
| 1.3.6.1.4.1.4756.20.502.20.1.558 | ColumnnidPort6RxDuplicateErrorEventRemoteB | read-only | current | NID Series card Port6 Detailed Link OAM Statistics: Rx Duplicate Error Event Notification |
| 1.3.6.1.4.1.4756.20.502.20.1.559 | ColumnnidPort6RxLoopBackControlRemoteB | read-only | current | NID Series card Port6 Detailed Link OAM Statistics: Rx Loopback Control |
| 1.3.6.1.4.1.4756.20.502.20.1.560 | ColumnnidPort6RxVariableRequestRemoteB | read-only | current | NID Series card Port6 Detailed Link OAM Statistics: Rx Variable Request |
| 1.3.6.1.4.1.4756.20.502.20.1.561 | ColumnnidPort6RxVariableResponseRemoteB | read-only | current | NID Series card Port6 Detailed Link OAM Statistics: Rx Variable Response |
| 1.3.6.1.4.1.4756.20.502.20.1.562 | ColumnnidPort6RxOrgSpecificPDURemoteB | read-only | current | NID Series card Port6 Detailed Link OAM Statistics: Rx Org Specific PDU's |
| 1.3.6.1.4.1.4756.20.502.20.1.563 | ColumnnidPort6RxUnsupportedCodesRemoteB | read-only | current | NID Series card Port6 Detailed Link OAM Statistics: Rx Unsupported Codes |
| 1.3.6.1.4.1.4756.20.502.20.1.564 | ColumnnidPort6RxLinkFaultPDURemoteB | read-only | current | NID Series card Port6 Detailed Link OAM Statistics: Rx Link Fault PDU's |
| 1.3.6.1.4.1.4756.20.502.20.1.565 | ColumnnidPort6RxDyingGaspRemoteB | read-only | current | NID Series card Port6 Detailed Link OAM Statistics: Rx Dying Gasp |
| 1.3.6.1.4.1.4756.20.502.20.1.566 | ColumnnidPort6RxCriticalEventPDURemoteB | read-only | current | NID Series card Port6 Detailed Link OAM Statistics: Rx Dying Gasp |
| 1.3.6.1.4.1.4756.20.502.20.1.567 | ColumnnidPort6TxOAMInfoPDURemoteB | read-only | current | NID Series card Port6 Detailed Link OAM Statistics: Tx OAM Information PDU's |
| 1.3.6.1.4.1.4756.20.502.20.1.568 | ColumnnidPort6TxUniqueErrorEventRemoteB | read-only | current | NID Series card Port6 Detailed Link OAM Statistics: Tx Unique Error Event Notificatio |
| 1.3.6.1.4.1.4756.20.502.20.1.569 | ColumnnidPort6TxDuplicateErrorEventRemoteB | read-only | current | NID Series card Port6 Detailed Link OAM Statistics: Tx Duplicate Error Event Notification |
| 1.3.6.1.4.1.4756.20.502.20.1.570 | ColumnnidPort6TxLoopBackControlRemoteB | read-only | current | NID Series card Port6 Detailed Link OAM Statistics: Tx Loopback Control |
| 1.3.6.1.4.1.4756.20.502.20.1.571 | ColumnnidPort6TxVariableRequestRemoteB | read-only | current | NID Series card Port6 Detailed Link OAM Statistics: Tx Variable Request |
| 1.3.6.1.4.1.4756.20.502.20.1.572 | ColumnnidPort6TxVariableResponseRemoteB | read-only | current | NID Series card Port6 Detailed Link OAM Statistics: Tx Variable Response |
| 1.3.6.1.4.1.4756.20.502.20.1.573 | ColumnnidPort6TxOrgSpecificPDURemoteB | read-only | current | NID Series card Port6 Detailed Link OAM Statistics: Tx Org Specific PDU's |
| 1.3.6.1.4.1.4756.20.502.20.1.574 | ColumnnidPort6TxUnsupportedCodesRemoteB | read-only | current | NID Series card Port6 Detailed Link OAM Statistics: Tx Unsupported Codes |
| 1.3.6.1.4.1.4756.20.502.20.1.575 | ColumnnidPort6TxLinkFaultPDURemoteB | read-only | current | NID Series card Port6 Detailed Link OAM Statistics: Tx Link Fault PDU's |
| 1.3.6.1.4.1.4756.20.502.20.1.576 | ColumnnidPort6TxDyingGaspRemoteB | read-only | current | NID Series card Port6 Detailed Link OAM Statistics: Tx Dying Gasp |
| 1.3.6.1.4.1.4756.20.502.20.1.577 | ColumnnidPort6TxCriticalEventPDURemoteB | read-only | current | NID Series card Port6 Detailed Link OAM Statistics: Tx Dying Gasp |
| 1.3.6.1.4.1.4756.20.502.20.1.578 | ColumnnidPort7RxOAMInfoPDURemoteB | read-only | current | NID Series card Port7 Detailed Link OAM Statistics: Rx OAM Information PDU's |
| 1.3.6.1.4.1.4756.20.502.20.1.579 | ColumnnidPort7RxUniqueErrorEventRemoteB | read-only | current | NID Series card Port7 Detailed Link OAM Statistics: Rx Unique Error Event Notificatio |
| 1.3.6.1.4.1.4756.20.502.20.1.580 | ColumnnidPort7RxDuplicateErrorEventRemoteB | read-only | current | NID Series card Port7 Detailed Link OAM Statistics: Rx Duplicate Error Event Notification |
| 1.3.6.1.4.1.4756.20.502.20.1.581 | ColumnnidPort7RxLoopBackControlRemoteB | read-only | current | NID Series card Port7 Detailed Link OAM Statistics: Rx Loopback Control |
| 1.3.6.1.4.1.4756.20.502.20.1.582 | ColumnnidPort7RxVariableRequestRemoteB | read-only | current | NID Series card Port7 Detailed Link OAM Statistics: Rx Variable Request |
| 1.3.6.1.4.1.4756.20.502.20.1.583 | ColumnnidPort7RxVariableResponseRemoteB | read-only | current | NID Series card Port7 Detailed Link OAM Statistics: Rx Variable Response |
| 1.3.6.1.4.1.4756.20.502.20.1.584 | ColumnnidPort7RxOrgSpecificPDURemoteB | read-only | current | NID Series card Port7 Detailed Link OAM Statistics: Rx Org Specific PDU's |
| 1.3.6.1.4.1.4756.20.502.20.1.585 | ColumnnidPort7RxUnsupportedCodesRemoteB | read-only | current | NID Series card Port7 Detailed Link OAM Statistics: Rx Unsupported Codes |
| 1.3.6.1.4.1.4756.20.502.20.1.586 | ColumnnidPort7RxLinkFaultPDURemoteB | read-only | current | NID Series card Port7 Detailed Link OAM Statistics: Rx Link Fault PDU's |
| 1.3.6.1.4.1.4756.20.502.20.1.587 | ColumnnidPort7RxDyingGaspRemoteB | read-only | current | NID Series card Port7 Detailed Link OAM Statistics: Rx Dying Gasp |
| 1.3.6.1.4.1.4756.20.502.20.1.588 | ColumnnidPort7RxCriticalEventPDURemoteB | read-only | current | NID Series card Port7 Detailed Link OAM Statistics: Rx Dying Gasp |
| 1.3.6.1.4.1.4756.20.502.20.1.589 | ColumnnidPort7TxOAMInfoPDURemoteB | read-only | current | NID Series card Port7 Detailed Link OAM Statistics: Tx OAM Information PDU's |
| 1.3.6.1.4.1.4756.20.502.20.1.590 | ColumnnidPort7TxUniqueErrorEventRemoteB | read-only | current | NID Series card Port7 Detailed Link OAM Statistics: Tx Unique Error Event Notificatio |
| 1.3.6.1.4.1.4756.20.502.20.1.591 | ColumnnidPort7TxDuplicateErrorEventRemoteB | read-only | current | NID Series card Port7 Detailed Link OAM Statistics: Tx Duplicate Error Event Notification |
| 1.3.6.1.4.1.4756.20.502.20.1.592 | ColumnnidPort7TxLoopBackControlRemoteB | read-only | current | NID Series card Port7 Detailed Link OAM Statistics: Tx Loopback Control |
| 1.3.6.1.4.1.4756.20.502.20.1.593 | ColumnnidPort7TxVariableRequestRemoteB | read-only | current | NID Series card Port7 Detailed Link OAM Statistics: Tx Variable Request |
| 1.3.6.1.4.1.4756.20.502.20.1.594 | ColumnnidPort7TxVariableResponseRemoteB | read-only | current | NID Series card Port7 Detailed Link OAM Statistics: Tx Variable Response |
| 1.3.6.1.4.1.4756.20.502.20.1.595 | ColumnnidPort7TxOrgSpecificPDURemoteB | read-only | current | NID Series card Port7 Detailed Link OAM Statistics: Tx Org Specific PDU's |
| 1.3.6.1.4.1.4756.20.502.20.1.596 | ColumnnidPort7TxUnsupportedCodesRemoteB | read-only | current | NID Series card Port7 Detailed Link OAM Statistics: Tx Unsupported Codes |
| 1.3.6.1.4.1.4756.20.502.20.1.597 | ColumnnidPort7TxLinkFaultPDURemoteB | read-only | current | NID Series card Port7 Detailed Link OAM Statistics: Tx Link Fault PDU's |
| 1.3.6.1.4.1.4756.20.502.20.1.598 | ColumnnidPort7TxDyingGaspRemoteB | read-only | current | NID Series card Port7 Detailed Link OAM Statistics: Tx Dying Gasp |
| 1.3.6.1.4.1.4756.20.502.20.1.599 | ColumnnidPort7TxCriticalEventPDURemoteB | read-only | current | NID Series card Port7 Detailed Link OAM Statistics: Tx Dying Gasp |
| 1.3.6.1.4.1.4756.20.502.20.1.600 | ColumnnidPort8RxOAMInfoPDURemoteB | read-only | current | NID Series card Port8 Detailed Link OAM Statistics: Rx OAM Information PDU's |
| 1.3.6.1.4.1.4756.20.502.20.1.601 | ColumnnidPort8RxUniqueErrorEventRemoteB | read-only | current | NID Series card Port8 Detailed Link OAM Statistics: Rx Unique Error Event Notificatio |
| 1.3.6.1.4.1.4756.20.502.20.1.602 | ColumnnidPort8RxDuplicateErrorEventRemoteB | read-only | current | NID Series card Port8 Detailed Link OAM Statistics: Rx Duplicate Error Event Notification |
| 1.3.6.1.4.1.4756.20.502.20.1.603 | ColumnnidPort8RxLoopBackControlRemoteB | read-only | current | NID Series card Port8 Detailed Link OAM Statistics: Rx Loopback Control |
| 1.3.6.1.4.1.4756.20.502.20.1.604 | ColumnnidPort8RxVariableRequestRemoteB | read-only | current | NID Series card Port8 Detailed Link OAM Statistics: Rx Variable Request |
| 1.3.6.1.4.1.4756.20.502.20.1.605 | ColumnnidPort8RxVariableResponseRemoteB | read-only | current | NID Series card Port8 Detailed Link OAM Statistics: Rx Variable Response |
| 1.3.6.1.4.1.4756.20.502.20.1.606 | ColumnnidPort8RxOrgSpecificPDURemoteB | read-only | current | NID Series card Port8 Detailed Link OAM Statistics: Rx Org Specific PDU's |
| 1.3.6.1.4.1.4756.20.502.20.1.607 | ColumnnidPort8RxUnsupportedCodesRemoteB | read-only | current | NID Series card Port8 Detailed Link OAM Statistics: Rx Unsupported Codes |
| 1.3.6.1.4.1.4756.20.502.20.1.608 | ColumnnidPort8RxLinkFaultPDURemoteB | read-only | current | NID Series card Port8 Detailed Link OAM Statistics: Rx Link Fault PDU's |
| 1.3.6.1.4.1.4756.20.502.20.1.609 | ColumnnidPort8RxDyingGaspRemoteB | read-only | current | NID Series card Port8 Detailed Link OAM Statistics: Rx Dying Gasp |
| 1.3.6.1.4.1.4756.20.502.20.1.610 | ColumnnidPort8RxCriticalEventPDURemoteB | read-only | current | NID Series card Port8 Detailed Link OAM Statistics: Rx Dying Gasp |
| 1.3.6.1.4.1.4756.20.502.20.1.611 | ColumnnidPort8TxOAMInfoPDURemoteB | read-only | current | NID Series card Port8 Detailed Link OAM Statistics: Tx OAM Information PDU's |
| 1.3.6.1.4.1.4756.20.502.20.1.612 | ColumnnidPort8TxUniqueErrorEventRemoteB | read-only | current | NID Series card Port8 Detailed Link OAM Statistics: Tx Unique Error Event Notificatio |
| 1.3.6.1.4.1.4756.20.502.20.1.613 | ColumnnidPort8TxDuplicateErrorEventRemoteB | read-only | current | NID Series card Port8 Detailed Link OAM Statistics: Tx Duplicate Error Event Notification |
| 1.3.6.1.4.1.4756.20.502.20.1.614 | ColumnnidPort8TxLoopBackControlRemoteB | read-only | current | NID Series card Port8 Detailed Link OAM Statistics: Tx Loopback Control |
| 1.3.6.1.4.1.4756.20.502.20.1.615 | ColumnnidPort8TxVariableRequestRemoteB | read-only | current | NID Series card Port8 Detailed Link OAM Statistics: Tx Variable Request |
| 1.3.6.1.4.1.4756.20.502.20.1.616 | ColumnnidPort8TxVariableResponseRemoteB | read-only | current | NID Series card Port8 Detailed Link OAM Statistics: Tx Variable Response |
| 1.3.6.1.4.1.4756.20.502.20.1.617 | ColumnnidPort8TxOrgSpecificPDURemoteB | read-only | current | NID Series card Port8 Detailed Link OAM Statistics: Tx Org Specific PDU's |
| 1.3.6.1.4.1.4756.20.502.20.1.618 | ColumnnidPort8TxUnsupportedCodesRemoteB | read-only | current | NID Series card Port8 Detailed Link OAM Statistics: Tx Unsupported Codes |
| 1.3.6.1.4.1.4756.20.502.20.1.619 | ColumnnidPort8TxLinkFaultPDURemoteB | read-only | current | NID Series card Port8 Detailed Link OAM Statistics: Tx Link Fault PDU's |
| 1.3.6.1.4.1.4756.20.502.20.1.620 | ColumnnidPort8TxDyingGaspRemoteB | read-only | current | NID Series card Port8 Detailed Link OAM Statistics: Tx Dying Gasp |
| 1.3.6.1.4.1.4756.20.502.20.1.621 | ColumnnidPort8TxCriticalEventPDURemoteB | read-only | current | NID Series card Port8 Detailed Link OAM Statistics: Tx Dying Gasp |
| 1.3.6.1.4.1.4756.20.502.20.1.622 | ColumnnidPort1PDUPermisionRemoteB | read-only | current | NID Series card Detailed Link OAM Status for Port 1: PDU Permission |
| 1.3.6.1.4.1.4756.20.502.20.1.623 | ColumnnidPort1DiscoveryStateRemoteB | read-only | current | NID Series card Detailed Link OAM Status for Port 1: Discovery State |
| 1.3.6.1.4.1.4756.20.502.20.1.624 | ColumnnidPort1PeerMACAddrRemoteB | read-only | current | NID Series card Detailed Link OAM Status for Port 1: Discovery State |
| 1.3.6.1.4.1.4756.20.502.20.1.625 | ColumnnidPort1RemoteBModeRemoteB | read-only | current | NID Series card Detailed Link OAM Status for Port 1: RemoteB: Mode |
| 1.3.6.1.4.1.4756.20.502.20.1.626 | ColumnnidPort1RemoteBUnOperationRemoteB | read-only | current | NID Series card Detailed Link OAM Status for Port 1: RemoteB: Unidirectional Operation Support |
| 1.3.6.1.4.1.4756.20.502.20.1.627 | ColumnnidPort1RemoteBRemoteLbRemoteB | read-only | current | NID Series card Detailed Link OAM Status for Port 1: RemoteB: Remote Loopback Support |
| 1.3.6.1.4.1.4756.20.502.20.1.628 | ColumnnidPort1RemoteBLMRemoteB | read-only | current | NID Series card Detailed Link OAM Status for Port 1: RemoteB: Link Monitoring Support |
| 1.3.6.1.4.1.4756.20.502.20.1.629 | ColumnnidPort1RemoteBMIBRetrievalRemoteB | read-only | current | NID Series card Detailed Link OAM Status for Port 1: RemoteB: MIB Retrieval Support |
| 1.3.6.1.4.1.4756.20.502.20.1.630 | ColumnnidPort1RemoteBMTUSizeRemoteB | read-only | current | NID Series card Detailed Link OAM Status for Port 1: RemoteB: MTU Size |
| 1.3.6.1.4.1.4756.20.502.20.1.631 | ColumnnidPort1RemoteBMultiStateRemoteB | read-only | current | NID Series card Detailed Link OAM Status for Port 1: RemoteB: Multiplexer State |
| 1.3.6.1.4.1.4756.20.502.20.1.632 | ColumnnidPort1RemoteBParserStateRemoteB | read-only | current | NID Series card Detailed Link OAM Status for Port 1: RemoteB: Multiplexer State |
| 1.3.6.1.4.1.4756.20.502.20.1.633 | ColumnnidPort1RemoteBOUIRemoteB | read-only | current | NID Series card Detailed Link OAM Status for Port 1: RemoteB: Organizational Unique Identification |
| 1.3.6.1.4.1.4756.20.502.20.1.634 | ColumnnidPort1RemoteBPDURevRemoteB | read-only | current | NID Series card Detailed Link OAM Status for Port 1: RemoteB: PDU Revision |
| 1.3.6.1.4.1.4756.20.502.20.1.635 | ColumnnidPort1PeerModeRemoteB | read-only | current | NID Series card Detailed Link OAM Status for Port 1: Peer: Mode |
| 1.3.6.1.4.1.4756.20.502.20.1.636 | ColumnnidPort1PeerUnOperationRemoteB | read-only | current | NID Series card Detailed Link OAM Status for Port 1: Peer: Unidirectional Operation Support |
| 1.3.6.1.4.1.4756.20.502.20.1.637 | ColumnnidPort1PeerRemoteLbRemoteB | read-only | current | NID Series card Detailed Link OAM Status for Port 1: Peer: Remote Loopback Support |
| 1.3.6.1.4.1.4756.20.502.20.1.638 | ColumnnidPort1PeerLMRemoteB | read-only | current | NID Series card Detailed Link OAM Status for Port 1: Peer: Link Monitoring Support |
| 1.3.6.1.4.1.4756.20.502.20.1.639 | ColumnnidPort1PeerMIBRetrievalRemoteB | read-only | current | NID Series card Detailed Link OAM Status for Port 1: Peer: MIB Retrieval Support |
| 1.3.6.1.4.1.4756.20.502.20.1.640 | ColumnnidPort1PeerMTUSizeRemoteB | read-only | current | NID Series card Detailed Link OAM Status for Port 1: Peer: MTU Size |
| 1.3.6.1.4.1.4756.20.502.20.1.641 | ColumnnidPort1PeerMultiStateRemoteB | read-only | current | NID Series card Detailed Link OAM Status for Port 1: Peer: Multiplexer State |
| 1.3.6.1.4.1.4756.20.502.20.1.642 | ColumnnidPort1PeerParserStateRemoteB | read-only | current | NID Series card Detailed Link OAM Status for Port 1: Peer: Multiplexer State |
| 1.3.6.1.4.1.4756.20.502.20.1.643 | ColumnnidPort1PeerOUIRemoteB | read-only | current | NID Series card Detailed Link OAM Status for Port 1: Peer: Organizational Unique Identification |
| 1.3.6.1.4.1.4756.20.502.20.1.644 | ColumnnidPort1PeerPDURevRemoteB | read-only | current | NID Series card Detailed Link OAM Status for Port 1: Peer: PDU Revision |
| 1.3.6.1.4.1.4756.20.502.20.1.645 | ColumnnidPort2PDUPermisionRemoteB | read-only | current | NID Series card Detailed Link OAM Status for Port 2: PDU Permission |
| 1.3.6.1.4.1.4756.20.502.20.1.646 | ColumnnidPort2DiscoveryStateRemoteB | read-only | current | NID Series card Detailed Link OAM Status for Port 2: Discovery State |
| 1.3.6.1.4.1.4756.20.502.20.1.647 | ColumnnidPort2PeerMACAddrRemoteB | read-only | current | NID Series card Detailed Link OAM Status for Port 2: Discovery State |
| 1.3.6.1.4.1.4756.20.502.20.1.648 | ColumnnidPort2RemoteBModeRemoteB | read-only | current | NID Series card Detailed Link OAM Status for Port 2: RemoteB: Mode |
| 1.3.6.1.4.1.4756.20.502.20.1.649 | ColumnnidPort2RemoteBUnOperationRemoteB | read-only | current | NID Series card Detailed Link OAM Status for Port 2: RemoteB: Unidirectional Operation Support |
| 1.3.6.1.4.1.4756.20.502.20.1.650 | ColumnnidPort2RemoteBRemoteLbRemoteB | read-only | current | NID Series card Detailed Link OAM Status for Port 2: RemoteB: Remote Loopback Support |
| 1.3.6.1.4.1.4756.20.502.20.1.651 | ColumnnidPort2RemoteBLMRemoteB | read-only | current | NID Series card Detailed Link OAM Status for Port 2: RemoteB: Link Monitoring Support |
| 1.3.6.1.4.1.4756.20.502.20.1.652 | ColumnnidPort2RemoteBMIBRetrievalRemoteB | read-only | current | NID Series card Detailed Link OAM Status for Port 2: RemoteB: MIB Retrieval Support |
| 1.3.6.1.4.1.4756.20.502.20.1.653 | ColumnnidPort2RemoteBMTUSizeRemoteB | read-only | current | NID Series card Detailed Link OAM Status for Port 2: RemoteB: MTU Size |
| 1.3.6.1.4.1.4756.20.502.20.1.654 | ColumnnidPort2RemoteBMultiStateRemoteB | read-only | current | NID Series card Detailed Link OAM Status for Port 2: RemoteB: Multiplexer State |
| 1.3.6.1.4.1.4756.20.502.20.1.655 | ColumnnidPort2RemoteBParserStateRemoteB | read-only | current | NID Series card Detailed Link OAM Status for Port 2: RemoteB: Multiplexer State |
| 1.3.6.1.4.1.4756.20.502.20.1.656 | ColumnnidPort2RemoteBOUIRemoteB | read-only | current | NID Series card Detailed Link OAM Status for Port 2: RemoteB: Organizational Unique Identification |
| 1.3.6.1.4.1.4756.20.502.20.1.657 | ColumnnidPort2RemoteBPDURevRemoteB | read-only | current | NID Series card Detailed Link OAM Status for Port 2: RemoteB: PDU Revision |
| 1.3.6.1.4.1.4756.20.502.20.1.658 | ColumnnidPort2PeerModeRemoteB | read-only | current | NID Series card Detailed Link OAM Status for Port 2: Peer: Mode |
| 1.3.6.1.4.1.4756.20.502.20.1.659 | ColumnnidPort2PeerUnOperationRemoteB | read-only | current | NID Series card Detailed Link OAM Status for Port 2: Peer: Unidirectional Operation Support |
| 1.3.6.1.4.1.4756.20.502.20.1.660 | ColumnnidPort2PeerRemoteLbRemoteB | read-only | current | NID Series card Detailed Link OAM Status for Port 2: Peer: Remote Loopback Support |
| 1.3.6.1.4.1.4756.20.502.20.1.661 | ColumnnidPort2PeerLMRemoteB | read-only | current | NID Series card Detailed Link OAM Status for Port 2: Peer: Link Monitoring Support |
| 1.3.6.1.4.1.4756.20.502.20.1.662 | ColumnnidPort2PeerMIBRetrievalRemoteB | read-only | current | NID Series card Detailed Link OAM Status for Port 2: Peer: MIB Retrieval Support |
| 1.3.6.1.4.1.4756.20.502.20.1.663 | ColumnnidPort2PeerMTUSizeRemoteB | read-only | current | NID Series card Detailed Link OAM Status for Port 2: Peer: MTU Size |
| 1.3.6.1.4.1.4756.20.502.20.1.664 | ColumnnidPort2PeerMultiStateRemoteB | read-only | current | NID Series card Detailed Link OAM Status for Port 2: Peer: Multiplexer State |
| 1.3.6.1.4.1.4756.20.502.20.1.665 | ColumnnidPort2PeerParserStateRemoteB | read-only | current | NID Series card Detailed Link OAM Status for Port 2: Peer: Multiplexer State |
| 1.3.6.1.4.1.4756.20.502.20.1.666 | ColumnnidPort2PeerOUIRemoteB | read-only | current | NID Series card Detailed Link OAM Status for Port 2: Peer: Organizational Unique Identification |
| 1.3.6.1.4.1.4756.20.502.20.1.667 | ColumnnidPort2PeerPDURevRemoteB | read-only | current | NID Series card Detailed Link OAM Status for Port 2: Peer: PDU Revision |
| 1.3.6.1.4.1.4756.20.502.20.1.668 | ColumnnidPort3PDUPermisionRemoteB | read-only | current | NID Series card Detailed Link OAM Status for Port 3: PDU Permission |
| 1.3.6.1.4.1.4756.20.502.20.1.669 | ColumnnidPort3DiscoveryStateRemoteB | read-only | current | NID Series card Detailed Link OAM Status for Port 3: Discovery State |
| 1.3.6.1.4.1.4756.20.502.20.1.670 | ColumnnidPort3PeerMACAddrRemoteB | read-only | current | NID Series card Detailed Link OAM Status for Port 3: Discovery State |
| 1.3.6.1.4.1.4756.20.502.20.1.671 | ColumnnidPort3RemoteBModeRemoteB | read-only | current | NID Series card Detailed Link OAM Status for Port 3: RemoteB: Mode |
| 1.3.6.1.4.1.4756.20.502.20.1.672 | ColumnnidPort3RemoteBUnOperationRemoteB | read-only | current | NID Series card Detailed Link OAM Status for Port 3: RemoteB: Unidirectional Operation Support |
| 1.3.6.1.4.1.4756.20.502.20.1.673 | ColumnnidPort3RemoteBRemoteLbRemoteB | read-only | current | NID Series card Detailed Link OAM Status for Port 3: RemoteB: Remote Loopback Support |
| 1.3.6.1.4.1.4756.20.502.20.1.674 | ColumnnidPort3RemoteBLMRemoteB | read-only | current | NID Series card Detailed Link OAM Status for Port 3: RemoteB: Link Monitoring Support |
| 1.3.6.1.4.1.4756.20.502.20.1.675 | ColumnnidPort3RemoteBMIBRetrievalRemoteB | read-only | current | NID Series card Detailed Link OAM Status for Port 3: RemoteB: MIB Retrieval Support |
| 1.3.6.1.4.1.4756.20.502.20.1.676 | ColumnnidPort3RemoteBMTUSizeRemoteB | read-only | current | NID Series card Detailed Link OAM Status for Port 3: RemoteB: MTU Size |
| 1.3.6.1.4.1.4756.20.502.20.1.677 | ColumnnidPort3RemoteBMultiStateRemoteB | read-only | current | NID Series card Detailed Link OAM Status for Port 3: RemoteB: Multiplexer State |
| 1.3.6.1.4.1.4756.20.502.20.1.678 | ColumnnidPort3RemoteBParserStateRemoteB | read-only | current | NID Series card Detailed Link OAM Status for Port 3: RemoteB: Multiplexer State |
| 1.3.6.1.4.1.4756.20.502.20.1.679 | ColumnnidPort3RemoteBOUIRemoteB | read-only | current | NID Series card Detailed Link OAM Status for Port 3: RemoteB: Organizational Unique Identification |
| 1.3.6.1.4.1.4756.20.502.20.1.680 | ColumnnidPort3RemoteBPDURevRemoteB | read-only | current | NID Series card Detailed Link OAM Status for Port 3: RemoteB: PDU Revision |
| 1.3.6.1.4.1.4756.20.502.20.1.681 | ColumnnidPort3PeerModeRemoteB | read-only | current | NID Series card Detailed Link OAM Status for Port 3: Peer: Mode |
| 1.3.6.1.4.1.4756.20.502.20.1.682 | ColumnnidPort3PeerUnOperationRemoteB | read-only | current | NID Series card Detailed Link OAM Status for Port 3: Peer: Unidirectional Operation Support |
| 1.3.6.1.4.1.4756.20.502.20.1.683 | ColumnnidPort3PeerRemoteLbRemoteB | read-only | current | NID Series card Detailed Link OAM Status for Port 3: Peer: Remote Loopback Support |
| 1.3.6.1.4.1.4756.20.502.20.1.684 | ColumnnidPort3PeerLMRemoteB | read-only | current | NID Series card Detailed Link OAM Status for Port 3: Peer: Link Monitoring Support |
| 1.3.6.1.4.1.4756.20.502.20.1.685 | ColumnnidPort3PeerMIBRetrievalRemoteB | read-only | current | NID Series card Detailed Link OAM Status for Port 3: Peer: MIB Retrieval Support |
| 1.3.6.1.4.1.4756.20.502.20.1.686 | ColumnnidPort3PeerMTUSizeRemoteB | read-only | current | NID Series card Detailed Link OAM Status for Port 3: Peer: MTU Size |
| 1.3.6.1.4.1.4756.20.502.20.1.687 | ColumnnidPort3PeerMultiStateRemoteB | read-only | current | NID Series card Detailed Link OAM Status for Port 3: Peer: Multiplexer State |
| 1.3.6.1.4.1.4756.20.502.20.1.688 | ColumnnidPort3PeerParserStateRemoteB | read-only | current | NID Series card Detailed Link OAM Status for Port 3: Peer: Multiplexer State |
| 1.3.6.1.4.1.4756.20.502.20.1.689 | ColumnnidPort3PeerOUIRemoteB | read-only | current | NID Series card Detailed Link OAM Status for Port 3: Peer: Organizational Unique Identification |
| 1.3.6.1.4.1.4756.20.502.20.1.690 | ColumnnidPort3PeerPDURevRemoteB | read-only | current | NID Series card Detailed Link OAM Status for Port 3: Peer: PDU Revision |
| 1.3.6.1.4.1.4756.20.502.20.1.691 | ColumnnidPort4PDUPermisionRemoteB | read-only | current | NID Series card Detailed Link OAM Status for Port 4: PDU Permission |
| 1.3.6.1.4.1.4756.20.502.20.1.692 | ColumnnidPort4DiscoveryStateRemoteB | read-only | current | NID Series card Detailed Link OAM Status for Port 4: Discovery State |
| 1.3.6.1.4.1.4756.20.502.20.1.693 | ColumnnidPort4PeerMACAddrRemoteB | read-only | current | NID Series card Detailed Link OAM Status for Port 4: Discovery State |
| 1.3.6.1.4.1.4756.20.502.20.1.694 | ColumnnidPort4RemoteBModeRemoteB | read-only | current | NID Series card Detailed Link OAM Status for Port 4: RemoteB: Mode |
| 1.3.6.1.4.1.4756.20.502.20.1.695 | ColumnnidPort4RemoteBUnOperationRemoteB | read-only | current | NID Series card Detailed Link OAM Status for Port 4: RemoteB: Unidirectional Operation Support |
| 1.3.6.1.4.1.4756.20.502.20.1.696 | ColumnnidPort4RemoteBRemoteLbRemoteB | read-only | current | NID Series card Detailed Link OAM Status for Port 4: RemoteB: Remote Loopback Support |
| 1.3.6.1.4.1.4756.20.502.20.1.697 | ColumnnidPort4RemoteBLMRemoteB | read-only | current | NID Series card Detailed Link OAM Status for Port 4: RemoteB: Link Monitoring Support |
| 1.3.6.1.4.1.4756.20.502.20.1.698 | ColumnnidPort4RemoteBMIBRetrievalRemoteB | read-only | current | NID Series card Detailed Link OAM Status for Port 4: RemoteB: MIB Retrieval Support |
| 1.3.6.1.4.1.4756.20.502.20.1.699 | ColumnnidPort4RemoteBMTUSizeRemoteB | read-only | current | NID Series card Detailed Link OAM Status for Port 4: RemoteB: MTU Size |
| 1.3.6.1.4.1.4756.20.502.20.1.700 | ColumnnidPort4RemoteBMultiStateRemoteB | read-only | current | NID Series card Detailed Link OAM Status for Port 4: RemoteB: Multiplexer State |
| 1.3.6.1.4.1.4756.20.502.20.1.701 | ColumnnidPort4RemoteBParserStateRemoteB | read-only | current | NID Series card Detailed Link OAM Status for Port 4: RemoteB: Multiplexer State |
| 1.3.6.1.4.1.4756.20.502.20.1.702 | ColumnnidPort4RemoteBOUIRemoteB | read-only | current | NID Series card Detailed Link OAM Status for Port 4: RemoteB: Organizational Unique Identification |
| 1.3.6.1.4.1.4756.20.502.20.1.703 | ColumnnidPort4RemoteBPDURevRemoteB | read-only | current | NID Series card Detailed Link OAM Status for Port 4: RemoteB: PDU Revision |
| 1.3.6.1.4.1.4756.20.502.20.1.704 | ColumnnidPort4PeerModeRemoteB | read-only | current | NID Series card Detailed Link OAM Status for Port 4: Peer: Mode |
| 1.3.6.1.4.1.4756.20.502.20.1.705 | ColumnnidPort4PeerUnOperationRemoteB | read-only | current | NID Series card Detailed Link OAM Status for Port 4: Peer: Unidirectional Operation Support |
| 1.3.6.1.4.1.4756.20.502.20.1.706 | ColumnnidPort4PeerRemoteLbRemoteB | read-only | current | NID Series card Detailed Link OAM Status for Port 4: Peer: Remote Loopback Support |
| 1.3.6.1.4.1.4756.20.502.20.1.707 | ColumnnidPort4PeerLMRemoteB | read-only | current | NID Series card Detailed Link OAM Status for Port 4: Peer: Link Monitoring Support |
| 1.3.6.1.4.1.4756.20.502.20.1.708 | ColumnnidPort4PeerMIBRetrievalRemoteB | read-only | current | NID Series card Detailed Link OAM Status for Port 4: Peer: MIB Retrieval Support |
| 1.3.6.1.4.1.4756.20.502.20.1.709 | ColumnnidPort4PeerMTUSizeRemoteB | read-only | current | NID Series card Detailed Link OAM Status for Port 4: Peer: MTU Size |
| 1.3.6.1.4.1.4756.20.502.20.1.710 | ColumnnidPort4PeerMultiStateRemoteB | read-only | current | NID Series card Detailed Link OAM Status for Port 4: Peer: Multiplexer State |
| 1.3.6.1.4.1.4756.20.502.20.1.711 | ColumnnidPort4PeerParserStateRemoteB | read-only | current | NID Series card Detailed Link OAM Status for Port 4: Peer: Multiplexer State |
| 1.3.6.1.4.1.4756.20.502.20.1.712 | ColumnnidPort4PeerOUIRemoteB | read-only | current | NID Series card Detailed Link OAM Status for Port 4: Peer: Organizational Unique Identification |
| 1.3.6.1.4.1.4756.20.502.20.1.713 | ColumnnidPort4PeerPDURevRemoteB | read-only | current | NID Series card Detailed Link OAM Status for Port 4: Peer: PDU Revision |
| 1.3.6.1.4.1.4756.20.502.20.1.714 | ColumnnidPort5PDUPermisionRemoteB | read-only | current | NID Series card Detailed Link OAM Status for Port 5: PDU Permission |
| 1.3.6.1.4.1.4756.20.502.20.1.715 | ColumnnidPort5DiscoveryStateRemoteB | read-only | current | NID Series card Detailed Link OAM Status for Port 5: Discovery State |
| 1.3.6.1.4.1.4756.20.502.20.1.716 | ColumnnidPort5PeerMACAddrRemoteB | read-only | current | NID Series card Detailed Link OAM Status for Port 5: Discovery State |
| 1.3.6.1.4.1.4756.20.502.20.1.717 | ColumnnidPort5RemoteBModeRemoteB | read-only | current | NID Series card Detailed Link OAM Status for Port 5: RemoteB: Mode |
| 1.3.6.1.4.1.4756.20.502.20.1.718 | ColumnnidPort5RemoteBUnOperationRemoteB | read-only | current | NID Series card Detailed Link OAM Status for Port 5: RemoteB: Unidirectional Operation Support |
| 1.3.6.1.4.1.4756.20.502.20.1.719 | ColumnnidPort5RemoteBRemoteLbRemoteB | read-only | current | NID Series card Detailed Link OAM Status for Port 5: RemoteB: Remote Loopback Support |
| 1.3.6.1.4.1.4756.20.502.20.1.720 | ColumnnidPort5RemoteBLMRemoteB | read-only | current | NID Series card Detailed Link OAM Status for Port 5: RemoteB: Link Monitoring Support |
| 1.3.6.1.4.1.4756.20.502.20.1.721 | ColumnnidPort5RemoteBMIBRetrievalRemoteB | read-only | current | NID Series card Detailed Link OAM Status for Port 5: RemoteB: MIB Retrieval Support |
| 1.3.6.1.4.1.4756.20.502.20.1.722 | ColumnnidPort5RemoteBMTUSizeRemoteB | read-only | current | NID Series card Detailed Link OAM Status for Port 5: RemoteB: MTU Size |
| 1.3.6.1.4.1.4756.20.502.20.1.723 | ColumnnidPort5RemoteBMultiStateRemoteB | read-only | current | NID Series card Detailed Link OAM Status for Port 5: RemoteB: Multiplexer State |
| 1.3.6.1.4.1.4756.20.502.20.1.724 | ColumnnidPort5RemoteBParserStateRemoteB | read-only | current | NID Series card Detailed Link OAM Status for Port 5: RemoteB: Multiplexer State |
| 1.3.6.1.4.1.4756.20.502.20.1.725 | ColumnnidPort5RemoteBOUIRemoteB | read-only | current | NID Series card Detailed Link OAM Status for Port 5: RemoteB: Organizational Unique Identification |
| 1.3.6.1.4.1.4756.20.502.20.1.726 | ColumnnidPort5RemoteBPDURevRemoteB | read-only | current | NID Series card Detailed Link OAM Status for Port 5: RemoteB: PDU Revision |
| 1.3.6.1.4.1.4756.20.502.20.1.727 | ColumnnidPort5PeerModeRemoteB | read-only | current | NID Series card Detailed Link OAM Status for Port 5: Peer: Mode |
| 1.3.6.1.4.1.4756.20.502.20.1.728 | ColumnnidPort5PeerUnOperationRemoteB | read-only | current | NID Series card Detailed Link OAM Status for Port 5: Peer: Unidirectional Operation Support |
| 1.3.6.1.4.1.4756.20.502.20.1.729 | ColumnnidPort5PeerRemoteLbRemoteB | read-only | current | NID Series card Detailed Link OAM Status for Port 5: Peer: Remote Loopback Support |
| 1.3.6.1.4.1.4756.20.502.20.1.730 | ColumnnidPort5PeerLMRemoteB | read-only | current | NID Series card Detailed Link OAM Status for Port 5: Peer: Link Monitoring Support |
| 1.3.6.1.4.1.4756.20.502.20.1.731 | ColumnnidPort5PeerMIBRetrievalRemoteB | read-only | current | NID Series card Detailed Link OAM Status for Port 5: Peer: MIB Retrieval Support |
| 1.3.6.1.4.1.4756.20.502.20.1.732 | ColumnnidPort5PeerMTUSizeRemoteB | read-only | current | NID Series card Detailed Link OAM Status for Port 5: Peer: MTU Size |
| 1.3.6.1.4.1.4756.20.502.20.1.733 | ColumnnidPort5PeerMultiStateRemoteB | read-only | current | NID Series card Detailed Link OAM Status for Port 5: Peer: Multiplexer State |
| 1.3.6.1.4.1.4756.20.502.20.1.734 | ColumnnidPort5PeerParserStateRemoteB | read-only | current | NID Series card Detailed Link OAM Status for Port 5: Peer: Multiplexer State |
| 1.3.6.1.4.1.4756.20.502.20.1.735 | ColumnnidPort5PeerOUIRemoteB | read-only | current | NID Series card Detailed Link OAM Status for Port 5: Peer: Organizational Unique Identification |
| 1.3.6.1.4.1.4756.20.502.20.1.736 | ColumnnidPort5PeerPDURevRemoteB | read-only | current | NID Series card Detailed Link OAM Status for Port 5: Peer: PDU Revision |
| 1.3.6.1.4.1.4756.20.502.20.1.737 | ColumnnidPort6PDUPermisionRemoteB | read-only | current | NID Series card Detailed Link OAM Status for Port 6: PDU Permission |
| 1.3.6.1.4.1.4756.20.502.20.1.738 | ColumnnidPort6DiscoveryStateRemoteB | read-only | current | NID Series card Detailed Link OAM Status for Port 6: Discovery State |
| 1.3.6.1.4.1.4756.20.502.20.1.739 | ColumnnidPort6PeerMACAddrRemoteB | read-only | current | NID Series card Detailed Link OAM Status for Port 6: Discovery State |
| 1.3.6.1.4.1.4756.20.502.20.1.740 | ColumnnidPort6RemoteBModeRemoteB | read-only | current | NID Series card Detailed Link OAM Status for Port 6: RemoteB: Mode |
| 1.3.6.1.4.1.4756.20.502.20.1.741 | ColumnnidPort6RemoteBUnOperationRemoteB | read-only | current | NID Series card Detailed Link OAM Status for Port 6: RemoteB: Unidirectional Operation Support |
| 1.3.6.1.4.1.4756.20.502.20.1.742 | ColumnnidPort6RemoteBRemoteLbRemoteB | read-only | current | NID Series card Detailed Link OAM Status for Port 6: RemoteB: Remote Loopback Support |
| 1.3.6.1.4.1.4756.20.502.20.1.743 | ColumnnidPort6RemoteBLMRemoteB | read-only | current | NID Series card Detailed Link OAM Status for Port 6: RemoteB: Link Monitoring Support |
| 1.3.6.1.4.1.4756.20.502.20.1.744 | ColumnnidPort6RemoteBMIBRetrievalRemoteB | read-only | current | NID Series card Detailed Link OAM Status for Port 6: RemoteB: MIB Retrieval Support |
| 1.3.6.1.4.1.4756.20.502.20.1.745 | ColumnnidPort6RemoteBMTUSizeRemoteB | read-only | current | NID Series card Detailed Link OAM Status for Port 6: RemoteB: MTU Size |
| 1.3.6.1.4.1.4756.20.502.20.1.746 | ColumnnidPort6RemoteBMultiStateRemoteB | read-only | current | NID Series card Detailed Link OAM Status for Port 6: RemoteB: Multiplexer State |
| 1.3.6.1.4.1.4756.20.502.20.1.747 | ColumnnidPort6RemoteBParserStateRemoteB | read-only | current | NID Series card Detailed Link OAM Status for Port 6: RemoteB: Multiplexer State |
| 1.3.6.1.4.1.4756.20.502.20.1.748 | ColumnnidPort6RemoteBOUIRemoteB | read-only | current | NID Series card Detailed Link OAM Status for Port 6: RemoteB: Organizational Unique Identification |
| 1.3.6.1.4.1.4756.20.502.20.1.749 | ColumnnidPort6RemoteBPDURevRemoteB | read-only | current | NID Series card Detailed Link OAM Status for Port 6: RemoteB: PDU Revision |
| 1.3.6.1.4.1.4756.20.502.20.1.750 | ColumnnidPort6PeerModeRemoteB | read-only | current | NID Series card Detailed Link OAM Status for Port 6: Peer: Mode |
| 1.3.6.1.4.1.4756.20.502.20.1.751 | ColumnnidPort6PeerUnOperationRemoteB | read-only | current | NID Series card Detailed Link OAM Status for Port 6: Peer: Unidirectional Operation Support |
| 1.3.6.1.4.1.4756.20.502.20.1.752 | ColumnnidPort6PeerRemoteLbRemoteB | read-only | current | NID Series card Detailed Link OAM Status for Port 6: Peer: Remote Loopback Support |
| 1.3.6.1.4.1.4756.20.502.20.1.753 | ColumnnidPort6PeerLMRemoteB | read-only | current | NID Series card Detailed Link OAM Status for Port 6: Peer: Link Monitoring Support |
| 1.3.6.1.4.1.4756.20.502.20.1.754 | ColumnnidPort6PeerMIBRetrievalRemoteB | read-only | current | NID Series card Detailed Link OAM Status for Port 6: Peer: MIB Retrieval Support |
| 1.3.6.1.4.1.4756.20.502.20.1.755 | ColumnnidPort6PeerMTUSizeRemoteB | read-only | current | NID Series card Detailed Link OAM Status for Port 6: Peer: MTU Size |
| 1.3.6.1.4.1.4756.20.502.20.1.756 | ColumnnidPort6PeerMultiStateRemoteB | read-only | current | NID Series card Detailed Link OAM Status for Port 6: Peer: Multiplexer State |
| 1.3.6.1.4.1.4756.20.502.20.1.757 | ColumnnidPort6PeerParserStateRemoteB | read-only | current | NID Series card Detailed Link OAM Status for Port 6: Peer: Multiplexer State |
| 1.3.6.1.4.1.4756.20.502.20.1.758 | ColumnnidPort6PeerOUIRemoteB | read-only | current | NID Series card Detailed Link OAM Status for Port 6: Peer: Organizational Unique Identification |
| 1.3.6.1.4.1.4756.20.502.20.1.759 | ColumnnidPort6PeerPDURevRemoteB | read-only | current | NID Series card Detailed Link OAM Status for Port 6: Peer: PDU Revision |
| 1.3.6.1.4.1.4756.20.502.20.1.760 | ColumnnidPort7PDUPermisionRemoteB | read-only | current | NID Series card Detailed Link OAM Status for Port 7: PDU Permission |
| 1.3.6.1.4.1.4756.20.502.20.1.761 | ColumnnidPort7DiscoveryStateRemoteB | read-only | current | NID Series card Detailed Link OAM Status for Port 7: Discovery State |
| 1.3.6.1.4.1.4756.20.502.20.1.762 | ColumnnidPort7PeerMACAddrRemoteB | read-only | current | NID Series card Detailed Link OAM Status for Port 7: Discovery State |
| 1.3.6.1.4.1.4756.20.502.20.1.763 | ColumnnidPort7RemoteBModeRemoteB | read-only | current | NID Series card Detailed Link OAM Status for Port 7: RemoteB: Mode |
| 1.3.6.1.4.1.4756.20.502.20.1.764 | ColumnnidPort7RemoteBUnOperationRemoteB | read-only | current | NID Series card Detailed Link OAM Status for Port 7: RemoteB: Unidirectional Operation Support |
| 1.3.6.1.4.1.4756.20.502.20.1.765 | ColumnnidPort7RemoteBRemoteLbRemoteB | read-only | current | NID Series card Detailed Link OAM Status for Port 7: RemoteB: Remote Loopback Support |
| 1.3.6.1.4.1.4756.20.502.20.1.766 | ColumnnidPort7RemoteBLMRemoteB | read-only | current | NID Series card Detailed Link OAM Status for Port 7: RemoteB: Link Monitoring Support |
| 1.3.6.1.4.1.4756.20.502.20.1.767 | ColumnnidPort7RemoteBMIBRetrievalRemoteB | read-only | current | NID Series card Detailed Link OAM Status for Port 7: RemoteB: MIB Retrieval Support |
| 1.3.6.1.4.1.4756.20.502.20.1.768 | ColumnnidPort7RemoteBMTUSizeRemoteB | read-only | current | NID Series card Detailed Link OAM Status for Port 7: RemoteB: MTU Size |
| 1.3.6.1.4.1.4756.20.502.20.1.769 | ColumnnidPort7RemoteBMultiStateRemoteB | read-only | current | NID Series card Detailed Link OAM Status for Port 7: RemoteB: Multiplexer State |
| 1.3.6.1.4.1.4756.20.502.20.1.770 | ColumnnidPort7RemoteBParserStateRemoteB | read-only | current | NID Series card Detailed Link OAM Status for Port 7: RemoteB: Multiplexer State |
| 1.3.6.1.4.1.4756.20.502.20.1.771 | ColumnnidPort7RemoteBOUIRemoteB | read-only | current | NID Series card Detailed Link OAM Status for Port 7: RemoteB: Organizational Unique Identification |
| 1.3.6.1.4.1.4756.20.502.20.1.772 | ColumnnidPort7RemoteBPDURevRemoteB | read-only | current | NID Series card Detailed Link OAM Status for Port 7: RemoteB: PDU Revision |
| 1.3.6.1.4.1.4756.20.502.20.1.773 | ColumnnidPort7PeerModeRemoteB | read-only | current | NID Series card Detailed Link OAM Status for Port 7: Peer: Mode |
| 1.3.6.1.4.1.4756.20.502.20.1.774 | ColumnnidPort7PeerUnOperationRemoteB | read-only | current | NID Series card Detailed Link OAM Status for Port 7: Peer: Unidirectional Operation Support |
| 1.3.6.1.4.1.4756.20.502.20.1.775 | ColumnnidPort7PeerRemoteLbRemoteB | read-only | current | NID Series card Detailed Link OAM Status for Port 7: Peer: Remote Loopback Support |
| 1.3.6.1.4.1.4756.20.502.20.1.776 | ColumnnidPort7PeerLMRemoteB | read-only | current | NID Series card Detailed Link OAM Status for Port 7: Peer: Link Monitoring Support |
| 1.3.6.1.4.1.4756.20.502.20.1.777 | ColumnnidPort7PeerMIBRetrievalRemoteB | read-only | current | NID Series card Detailed Link OAM Status for Port 7: Peer: MIB Retrieval Support |
| 1.3.6.1.4.1.4756.20.502.20.1.778 | ColumnnidPort7PeerMTUSizeRemoteB | read-only | current | NID Series card Detailed Link OAM Status for Port 7: Peer: MTU Size |
| 1.3.6.1.4.1.4756.20.502.20.1.779 | ColumnnidPort7PeerMultiStateRemoteB | read-only | current | NID Series card Detailed Link OAM Status for Port 7: Peer: Multiplexer State |
| 1.3.6.1.4.1.4756.20.502.20.1.780 | ColumnnidPort7PeerParserStateRemoteB | read-only | current | NID Series card Detailed Link OAM Status for Port 7: Peer: Multiplexer State |
| 1.3.6.1.4.1.4756.20.502.20.1.781 | ColumnnidPort7PeerOUIRemoteB | read-only | current | NID Series card Detailed Link OAM Status for Port 7: Peer: Organizational Unique Identification |
| 1.3.6.1.4.1.4756.20.502.20.1.782 | ColumnnidPort7PeerPDURevRemoteB | read-only | current | NID Series card Detailed Link OAM Status for Port 7: Peer: PDU Revision |
| 1.3.6.1.4.1.4756.20.502.20.1.783 | ColumnnidPort8PDUPermisionRemoteB | read-only | current | NID Series card Detailed Link OAM Status for Port 8: PDU Permission |
| 1.3.6.1.4.1.4756.20.502.20.1.784 | ColumnnidPort8DiscoveryStateRemoteB | read-only | current | NID Series card Detailed Link OAM Status for Port 8: Discovery State |
| 1.3.6.1.4.1.4756.20.502.20.1.785 | ColumnnidPort8PeerMACAddrRemoteB | read-only | current | NID Series card Detailed Link OAM Status for Port 8: Discovery State |
| 1.3.6.1.4.1.4756.20.502.20.1.786 | ColumnnidPort8RemoteBModeRemoteB | read-only | current | NID Series card Detailed Link OAM Status for Port 8: RemoteB: Mode |
| 1.3.6.1.4.1.4756.20.502.20.1.787 | ColumnnidPort8RemoteBUnOperationRemoteB | read-only | current | NID Series card Detailed Link OAM Status for Port 8: RemoteB: Unidirectional Operation Support |
| 1.3.6.1.4.1.4756.20.502.20.1.788 | ColumnnidPort8RemoteBRemoteLbRemoteB | read-only | current | NID Series card Detailed Link OAM Status for Port 8: RemoteB: Remote Loopback Support |
| 1.3.6.1.4.1.4756.20.502.20.1.789 | ColumnnidPort8RemoteBLMRemoteB | read-only | current | NID Series card Detailed Link OAM Status for Port 8: RemoteB: Link Monitoring Support |
| 1.3.6.1.4.1.4756.20.502.20.1.790 | ColumnnidPort8RemoteBMIBRetrievalRemoteB | read-only | current | NID Series card Detailed Link OAM Status for Port 8: RemoteB: MIB Retrieval Support |
| 1.3.6.1.4.1.4756.20.502.20.1.791 | ColumnnidPort8RemoteBMTUSizeRemoteB | read-only | current | NID Series card Detailed Link OAM Status for Port 8: RemoteB: MTU Size |
| 1.3.6.1.4.1.4756.20.502.20.1.792 | ColumnnidPort8RemoteBMultiStateRemoteB | read-only | current | NID Series card Detailed Link OAM Status for Port 8: RemoteB: Multiplexer State |
| 1.3.6.1.4.1.4756.20.502.20.1.793 | ColumnnidPort8RemoteBParserStateRemoteB | read-only | current | NID Series card Detailed Link OAM Status for Port 8: RemoteB: Multiplexer State |
| 1.3.6.1.4.1.4756.20.502.20.1.794 | ColumnnidPort8RemoteBOUIRemoteB | read-only | current | NID Series card Detailed Link OAM Status for Port 8: RemoteB: Organizational Unique Identification |
| 1.3.6.1.4.1.4756.20.502.20.1.795 | ColumnnidPort8RemoteBPDURevRemoteB | read-only | current | NID Series card Detailed Link OAM Status for Port 8: RemoteB: PDU Revision |
| 1.3.6.1.4.1.4756.20.502.20.1.796 | ColumnnidPort8PeerModeRemoteB | read-only | current | NID Series card Detailed Link OAM Status for Port 8: Peer: Mode |
| 1.3.6.1.4.1.4756.20.502.20.1.797 | ColumnnidPort8PeerUnOperationRemoteB | read-only | current | NID Series card Detailed Link OAM Status for Port 8: Peer: Unidirectional Operation Support |
| 1.3.6.1.4.1.4756.20.502.20.1.798 | ColumnnidPort8PeerRemoteLbRemoteB | read-only | current | NID Series card Detailed Link OAM Status for Port 8: Peer: Remote Loopback Support |
| 1.3.6.1.4.1.4756.20.502.20.1.799 | ColumnnidPort8PeerLMRemoteB | read-only | current | NID Series card Detailed Link OAM Status for Port 8: Peer: Link Monitoring Support |
| 1.3.6.1.4.1.4756.20.502.20.1.800 | ColumnnidPort8PeerMIBRetrievalRemoteB | read-only | current | NID Series card Detailed Link OAM Status for Port 8: Peer: MIB Retrieval Support |
| 1.3.6.1.4.1.4756.20.502.20.1.801 | ColumnnidPort8PeerMTUSizeRemoteB | read-only | current | NID Series card Detailed Link OAM Status for Port 8: Peer: MTU Size |
| 1.3.6.1.4.1.4756.20.502.20.1.802 | ColumnnidPort8PeerMultiStateRemoteB | read-only | current | NID Series card Detailed Link OAM Status for Port 8: Peer: Multiplexer State |
| 1.3.6.1.4.1.4756.20.502.20.1.803 | ColumnnidPort8PeerParserStateRemoteB | read-only | current | NID Series card Detailed Link OAM Status for Port 8: Peer: Multiplexer State |
| 1.3.6.1.4.1.4756.20.502.20.1.804 | ColumnnidPort8PeerOUIRemoteB | read-only | current | NID Series card Detailed Link OAM Status for Port 8: Peer: Organizational Unique Identification |
| 1.3.6.1.4.1.4756.20.502.20.1.805 | ColumnnidPort8PeerPDURevRemoteB | read-only | current | NID Series card Detailed Link OAM Status for Port 8: Peer: PDU Revision |
| 1.3.6.1.4.1.4756.20.502.20.1.806 | ColumnnidLoopProtectionEnableRemoteB | read-write | current | NID Series card Loop Protection Configuration: General Settings - Enable Loop Protection 0: Disable 1: Enable |
| 1.3.6.1.4.1.4756.20.502.20.1.807 | ColumnnidLoopProtectionTxTimeRemoteB | read-write | current | NID Series card Loop Protection Configuration: General Settings - Transmission Time |
| 1.3.6.1.4.1.4756.20.502.20.1.808 | ColumnnidLoopProtectionShutdownTimeRemoteB | read-write | current | NID Series card Loop Protection Configuration: General Settings - Shutdown Time |
| 1.3.6.1.4.1.4756.20.502.20.1.809 | ColumnnidLoopProtectionPort1EnabledRemoteB | read-write | current | NID Series card Loop Protection Configuration for Port 1: Port Configuration - Enable 0: Disable 1: Enable |
| 1.3.6.1.4.1.4756.20.502.20.1.810 | ColumnnidLoopProtectionPort1ActionRemoteB | read-write | current | NID Series card Loop Protection Configuration for Port 1: Port Configuration - Action 0: Shutdown Port 1: Shutdown Port And Log 2: Log Only |
| 1.3.6.1.4.1.4756.20.502.20.1.811 | ColumnnidLoopProtectionPort1TxModeRemoteB | read-write | current | NID Series card Loop Protection Configuration for Port 1: Port Configuration - Tx Mode 0: Disable 1: Enable |
| 1.3.6.1.4.1.4756.20.502.20.1.812 | ColumnnidLoopProtectionPort2EnabledRemoteB | read-write | current | NID Series card Loop Protection Configuration for Port 2: Port Configuration - Enable 0: Disable 1: Enable |
| 1.3.6.1.4.1.4756.20.502.20.1.813 | ColumnnidLoopProtectionPort2ActionRemoteB | read-write | current | NID Series card Loop Protection Configuration for Port 2: Port Configuration - Action 0: Shutdown Port 1: Shutdown Port And Log 2: Log Only |
| 1.3.6.1.4.1.4756.20.502.20.1.814 | ColumnnidLoopProtectionPort2TxModeRemoteB | read-write | current | NID Series card Loop Protection Configuration for Port 2: Port Configuration - Tx Mode 0: Disable 1: Enable |
| 1.3.6.1.4.1.4756.20.502.20.1.815 | ColumnnidLoopProtectionPort3EnabledRemoteB | read-write | current | NID Series card Loop Protection Configuration for Port 3: Port Configuration - Enable 0: Disable 1: Enable |
| 1.3.6.1.4.1.4756.20.502.20.1.816 | ColumnnidLoopProtectionPort3ActionRemoteB | read-write | current | NID Series card Loop Protection Configuration for Port 3: Port Configuration - Action 0: Shutdown Port 1: Shutdown Port And Log 2: Log Only |
| 1.3.6.1.4.1.4756.20.502.20.1.817 | ColumnnidLoopProtectionPort3TxModeRemoteB | read-write | current | NID Series card Loop Protection Configuration for Port 3: Port Configuration - Tx Mode 0: Disable 1: Enable |
| 1.3.6.1.4.1.4756.20.502.20.1.818 | ColumnnidLoopProtectionPort4EnabledRemoteB | read-write | current | NID Series card Loop Protection Configuration for Port 4: Port Configuration - Enable 0: Disable 1: Enable |
| 1.3.6.1.4.1.4756.20.502.20.1.819 | ColumnnidLoopProtectionPort4ActionRemoteB | read-write | current | NID Series card Loop Protection Configuration for Port 4: Port Configuration - Action 0: Shutdown Port 1: Shutdown Port And Log 2: Log Only |
| 1.3.6.1.4.1.4756.20.502.20.1.820 | ColumnnidLoopProtectionPort4TxModeRemoteB | read-write | current | NID Series card Loop Protection Configuration for Port 41: Port Configuration - Tx Mode 0: Disable 1: Enable |
| 1.3.6.1.4.1.4756.20.502.20.1.821 | ColumnnidLoopProtectionPort5EnabledRemoteB | read-write | current | NID Series card Loop Protection Configuration for Port 5: Port Configuration - Enable 0: Disable 1: Enable |
| 1.3.6.1.4.1.4756.20.502.20.1.822 | ColumnnidLoopProtectionPort5ActionRemoteB | read-write | current | NID Series card Loop Protection Configuration for Port 5: Port Configuration - Action 0: Shutdown Port 1: Shutdown Port And Log 2: Log Only |
| 1.3.6.1.4.1.4756.20.502.20.1.823 | ColumnnidLoopProtectionPort5TxModeRemoteB | read-write | current | NID Series card Loop Protection Configuration for Port 5: Port Configuration - Tx Mode 0: Disable 1: Enable |
| 1.3.6.1.4.1.4756.20.502.20.1.824 | ColumnnidLoopProtectionPort6EnabledRemoteB | read-write | current | NID Series card Loop Protection Configuration for Port 6: Port Configuration - Enable 0: Disable 1: Enable |
| 1.3.6.1.4.1.4756.20.502.20.1.825 | ColumnnidLoopProtectionPort6ActionRemoteB | read-write | current | NID Series card Loop Protection Configuration for Port 6: Port Configuration - Action 0: Shutdown Port 1: Shutdown Port And Log 2: Log Only |
| 1.3.6.1.4.1.4756.20.502.20.1.826 | ColumnnidLoopProtectionPort6TxModeRemoteB | read-write | current | NID Series card Loop Protection Configuration for Port 6: Port Configuration - Tx Mode 0: Disable 1: Enable |
| 1.3.6.1.4.1.4756.20.502.20.1.827 | ColumnnidLoopProtectionPort7EnabledRemoteB | read-write | current | NID Series card Loop Protection Configuration for Port 7: Port Configuration - Enable 0: Disable 1: Enable |
| 1.3.6.1.4.1.4756.20.502.20.1.828 | ColumnnidLoopProtectionPort7ActionRemoteB | read-write | current | NID Series card Loop Protection Configuration for Port 7: Port Configuration - Action 0: Shutdown Port 1: Shutdown Port And Log 2: Log Only |
| 1.3.6.1.4.1.4756.20.502.20.1.829 | ColumnnidLoopProtectionPort7TxModeRemoteB | read-write | current | NID Series card Loop Protection Configuration for Port 7: Port Configuration - Tx Mode 0: Disable 1: Enable |
| 1.3.6.1.4.1.4756.20.502.20.1.830 | ColumnnidLoopProtectionPort8EnabledRemoteB | read-write | current | NID Series card Loop Protection Configuration for Port 8: Port Configuration - Enable 0: Disable 1: Enable |
| 1.3.6.1.4.1.4756.20.502.20.1.831 | ColumnnidLoopProtectionPort8ActionRemoteB | read-write | current | NID Series card Loop Protection Configuration for Port 8: Port Configuration - Action 0: Shutdown Port 1: Shutdown Port And Log 2: Log Only |
| 1.3.6.1.4.1.4756.20.502.20.1.832 | ColumnnidLoopProtectionPort8TxModeRemoteB | read-write | current | NID Series card Loop Protection Configuration for Port 8: Port Configuration - Tx Mode 0: Disable 1: Enable |
| 1.3.6.1.4.1.4756.20.502.20.1.833 | ColumnnidLoopProtectionPort1ActionStsRemoteB | read-only | current | NID Series card Loop Protection Status for Port 1: Action |
| 1.3.6.1.4.1.4756.20.502.20.1.834 | ColumnnidLoopProtectionPort1TransStsRemoteB | read-only | current | NID Series card Loop Protection Status for Port 1: Transmit |
| 1.3.6.1.4.1.4756.20.502.20.1.835 | ColumnnidLoopProtectionPort1LoopsStsRemoteB | read-only | current | NID Series card Loop Protection Status for Port 1: Loops |
| 1.3.6.1.4.1.4756.20.502.20.1.836 | ColumnnidLoopProtectionPort1StatusRemoteB | read-only | current | NID Series card Loop Protection Status for Port 1: Status |
| 1.3.6.1.4.1.4756.20.502.20.1.837 | ColumnnidLoopProtectionPort1LoopStsRemoteB | read-only | current | NID Series card Loop Protection Status for Port 1: Loop |
| 1.3.6.1.4.1.4756.20.502.20.1.838 | ColumnnidLoopProtectionPort1TimeOfLastLoopRemoteB | read-only | current | NID Series card Loop Protection Status for Port 1: Time of Last Loop |
| 1.3.6.1.4.1.4756.20.502.20.1.839 | ColumnnidLoopProtectionPort2ActionStsRemoteB | read-only | current | NID Series card Loop Protection Status for Port 2: Action |
| 1.3.6.1.4.1.4756.20.502.20.1.840 | ColumnnidLoopProtectionPort2TransStsRemoteB | read-only | current | NID Series card Loop Protection Status for Port 2: Transmit |
| 1.3.6.1.4.1.4756.20.502.20.1.841 | ColumnnidLoopProtectionPort2LoopsStsRemoteB | read-only | current | NID Series card Loop Protection Status for Port 2: Loops |
| 1.3.6.1.4.1.4756.20.502.20.1.842 | ColumnnidLoopProtectionPort2StatusRemoteB | read-only | current | NID Series card Loop Protection Status for Port 2: Status |
| 1.3.6.1.4.1.4756.20.502.20.1.843 | ColumnnidLoopProtectionPort2LoopStsRemoteB | read-only | current | NID Series card Loop Protection Status for Port 2: Loop |
| 1.3.6.1.4.1.4756.20.502.20.1.844 | ColumnnidLoopProtectionPort2TimeOfLastLoopRemoteB | read-only | current | NID Series card Loop Protection Status for Port 2: Time of Last Loop |
| 1.3.6.1.4.1.4756.20.502.20.1.845 | ColumnnidLoopProtectionPort3ActionStsRemoteB | read-only | current | NID Series card Loop Protection Status for Port 3: Action |
| 1.3.6.1.4.1.4756.20.502.20.1.846 | ColumnnidLoopProtectionPort3TransStsRemoteB | read-only | current | NID Series card Loop Protection Status for Port 3: Transmit |
| 1.3.6.1.4.1.4756.20.502.20.1.847 | ColumnnidLoopProtectionPort3LoopsStsRemoteB | read-only | current | NID Series card Loop Protection Status for Port 3: Loops |
| 1.3.6.1.4.1.4756.20.502.20.1.848 | ColumnnidLoopProtectionPort3StatusRemoteB | read-only | current | NID Series card Loop Protection Status for Port 3: Status |
| 1.3.6.1.4.1.4756.20.502.20.1.849 | ColumnnidLoopProtectionPort3LoopStsRemoteB | read-only | current | NID Series card Loop Protection Status for Port 3: Loop |
| 1.3.6.1.4.1.4756.20.502.20.1.850 | ColumnnidLoopProtectionPort3TimeOfLastLoopRemoteB | read-only | current | NID Series card Loop Protection Status for Port 3: Time of Last Loop |
| 1.3.6.1.4.1.4756.20.502.20.1.851 | ColumnnidLoopProtectionPort4ActionStsRemoteB | read-only | current | NID Series card Loop Protection Status for Port 4: Action |
| 1.3.6.1.4.1.4756.20.502.20.1.852 | ColumnnidLoopProtectionPort4TransStsRemoteB | read-only | current | NID Series card Loop Protection Status for Port 4: Transmit |
| 1.3.6.1.4.1.4756.20.502.20.1.853 | ColumnnidLoopProtectionPort4LoopsStsRemoteB | read-only | current | NID Series card Loop Protection Status for Port 4: Loops |
| 1.3.6.1.4.1.4756.20.502.20.1.854 | ColumnnidLoopProtectionPort4StatusRemoteB | read-only | current | NID Series card Loop Protection Status for Port 4: Status |
| 1.3.6.1.4.1.4756.20.502.20.1.855 | ColumnnidLoopProtectionPort4LoopStsRemoteB | read-only | current | NID Series card Loop Protection Status for Port 4: Loop |
| 1.3.6.1.4.1.4756.20.502.20.1.856 | ColumnnidLoopProtectionPort4TimeOfLastLoopRemoteB | read-only | current | NID Series card Loop Protection Status for Port 4: Time of Last Loop |
| 1.3.6.1.4.1.4756.20.502.20.1.857 | ColumnnidLoopProtectionPort5ActionStsRemoteB | read-only | current | NID Series card Loop Protection Status for Port 5: Action |
| 1.3.6.1.4.1.4756.20.502.20.1.858 | ColumnnidLoopProtectionPort5TransStsRemoteB | read-only | current | NID Series card Loop Protection Status for Port 5: Transmit |
| 1.3.6.1.4.1.4756.20.502.20.1.859 | ColumnnidLoopProtectionPort5LoopsStsRemoteB | read-only | current | NID Series card Loop Protection Status for Port 5: Loops |
| 1.3.6.1.4.1.4756.20.502.20.1.860 | ColumnnidLoopProtectionPort5StatusRemoteB | read-only | current | NID Series card Loop Protection Status for Port 5: Status |
| 1.3.6.1.4.1.4756.20.502.20.1.861 | ColumnnidLoopProtectionPort5LoopStsRemoteB | read-only | current | NID Series card Loop Protection Status for Port 5: Loop |
| 1.3.6.1.4.1.4756.20.502.20.1.862 | ColumnnidLoopProtectionPort5TimeOfLastLoopRemoteB | read-only | current | NID Series card Loop Protection Status for Port 5: Time of Last Loop |
| 1.3.6.1.4.1.4756.20.502.20.1.863 | ColumnnidLoopProtectionPort6ActionStsRemoteB | read-only | current | NID Series card Loop Protection Status for Port 6: Action |
| 1.3.6.1.4.1.4756.20.502.20.1.864 | ColumnnidLoopProtectionPort6TransStsRemoteB | read-only | current | NID Series card Loop Protection Status for Port 6: Transmit |
| 1.3.6.1.4.1.4756.20.502.20.1.865 | ColumnnidLoopProtectionPort6LoopsStsRemoteB | read-only | current | NID Series card Loop Protection Status for Port 6: Loops |
| 1.3.6.1.4.1.4756.20.502.20.1.866 | ColumnnidLoopProtectionPort6StatusRemoteB | read-only | current | NID Series card Loop Protection Status for Port 64: Status |
| 1.3.6.1.4.1.4756.20.502.20.1.867 | ColumnnidLoopProtectionPort6LoopStsRemoteB | read-only | current | NID Series card Loop Protection Status for Port 64: Loop |
| 1.3.6.1.4.1.4756.20.502.20.1.868 | ColumnnidLoopProtectionPort6TimeOfLastLoopRemoteB | read-only | current | NID Series card Loop Protection Status for Port 6: Time of Last Loop |
| 1.3.6.1.4.1.4756.20.502.20.1.869 | ColumnnidLoopProtectionPort7ActionStsRemoteB | read-only | current | NID Series card Loop Protection Status for Port 7: Action |
| 1.3.6.1.4.1.4756.20.502.20.1.870 | ColumnnidLoopProtectionPort7TransStsRemoteB | read-only | current | NID Series card Loop Protection Status for Port 7: Transmit |
| 1.3.6.1.4.1.4756.20.502.20.1.871 | ColumnnidLoopProtectionPort7LoopsStsRemoteB | read-only | current | NID Series card Loop Protection Status for Port 7: Loops |
| 1.3.6.1.4.1.4756.20.502.20.1.872 | ColumnnidLoopProtectionPort7StatusRemoteB | read-only | current | NID Series card Loop Protection Status for Port 7: Status |
| 1.3.6.1.4.1.4756.20.502.20.1.873 | ColumnnidLoopProtectionPort7LoopStsRemoteB | read-only | current | NID Series card Loop Protection Status for Port 7: Loop |
| 1.3.6.1.4.1.4756.20.502.20.1.874 | ColumnnidLoopProtectionPort7TimeOfLastLoopRemoteB | read-only | current | NID Series card Loop Protection Status for Port 7: Time of Last Loop |
| 1.3.6.1.4.1.4756.20.502.20.1.875 | ColumnnidLoopProtectionPort8ActionStsRemoteB | read-only | current | NID Series card Loop Protection Status for Port 8: Action |
| 1.3.6.1.4.1.4756.20.502.20.1.876 | ColumnnidLoopProtectionPort8TransStsRemoteB | read-only | current | NID Series card Loop Protection Status for Port 8: Transmit |
| 1.3.6.1.4.1.4756.20.502.20.1.877 | ColumnnidLoopProtectionPort8LoopsStsRemoteB | read-only | current | NID Series card Loop Protection Status for Port 8: Loops |
| 1.3.6.1.4.1.4756.20.502.20.1.878 | ColumnnidLoopProtectionPort8StatusRemoteB | read-only | current | NID Series card Loop Protection Status for Port 8: Status |
| 1.3.6.1.4.1.4756.20.502.20.1.879 | ColumnnidLoopProtectionPort8LoopStsRemoteB | read-only | current | NID Series card Loop Protection Status for Port 8: Loop |
| 1.3.6.1.4.1.4756.20.502.20.1.880 | ColumnnidLoopProtectionPort8TimeOfLastLoopRemoteB | read-only | current | NID Series card Loop Protection Status for Port 8: Time of Last Loop |
| 1.3.6.1.4.1.4756.20.502.20.1.881 | ColumnniduRingInstanceAddRemoteB | read-write | current | NID Series card Add a new uRing Instance. Syntax: <Instance ID> <ring|sub|chain> <port east> <port west> Instance ID must be either 1 or 2 port east , the valu… |
| 1.3.6.1.4.1.4756.20.502.20.1.882 | ColumnniduRingInstanceDeleteRemoteB | read-write | current | NID Series card Delete a uRing Instance. Syntax: <uRing Instance> |
| 1.3.6.1.4.1.4756.20.502.20.1.883 | ColumnniduRingInst1IDRemoteB | read-only | current | NID Series card u-Ring instance1 ID |
| 1.3.6.1.4.1.4756.20.502.20.1.884 | ColumnniduRingInst1typeRemoteB | read-only | current | NID Series card u-Ring instance1 type 0: u-Ring 1: Sub-Ring 2: u-Chain |
| 1.3.6.1.4.1.4756.20.502.20.1.885 | ColumnniduRingInst1masterRemoteB | read-write | current | NID Series card u-Ring instance1 master 0: No 1: Yes |
| 1.3.6.1.4.1.4756.20.502.20.1.886 | ColumnniduRingInst1EastPortRemoteB | read-only | current | NID Series card u-Ring instance1 east port |
| 1.3.6.1.4.1.4756.20.502.20.1.887 | ColumnniduRingInst1EastEdgeRemoteB | read-write | current | NID Series card u-Ring instance1 east edge 0: No 1: Yes |
| 1.3.6.1.4.1.4756.20.502.20.1.888 | ColumnniduRingInst1WestPortRemoteB | read-only | current | NID Series card u-Ring instance1 west port |
| 1.3.6.1.4.1.4756.20.502.20.1.889 | ColumnniduRingInst1WestEdgeRemoteB | read-write | current | NID Series card u-Ring instance1 west edge 0: No 1: Yes |
| 1.3.6.1.4.1.4756.20.502.20.1.890 | ColumnniduRingInst2IDRemoteB | read-only | current | NID Series card u-Ring instance2 ID |
| 1.3.6.1.4.1.4756.20.502.20.1.891 | ColumnniduRingInst2typeRemoteB | read-only | current | NID Series card u-Ring instance2 type 0: u-Ring 1: Sub-Ring 2: u-Chain |
| 1.3.6.1.4.1.4756.20.502.20.1.892 | ColumnniduRingInst2masterRemoteB | read-write | current | NID Series card u-Ring instance2 master 0: No 1: Yes |
| 1.3.6.1.4.1.4756.20.502.20.1.893 | ColumnniduRingInst2EastPortRemoteB | read-only | current | NID Series card u-Ring instance2 east port |
| 1.3.6.1.4.1.4756.20.502.20.1.894 | ColumnniduRingInst2EastEdgeRemoteB | read-write | current | NID Series card u-Ring instance2 east edge 0: No 1: Yes |
| 1.3.6.1.4.1.4756.20.502.20.1.895 | ColumnniduRingInst2WestPortRemoteB | read-only | current | NID Series card u-Ring instance2 west port |
| 1.3.6.1.4.1.4756.20.502.20.1.896 | ColumnniduRingInst2WestEdgeRemoteB | read-write | current | NID Series card u-Ring instance2 west edge 0: No 1: Yes |
| 1.3.6.1.4.1.4756.20.502.20.1.897 | ColumnniduRingInst3IDRemoteB | read-only | current | NID Series card u-Ring instance3 ID |
| 1.3.6.1.4.1.4756.20.502.20.1.898 | ColumnniduRingInst3typeRemoteB | read-only | current | NID Series card u-Ring instance3 type 0: u-Ring 1: Sub-Ring 2: u-Chain |
| 1.3.6.1.4.1.4756.20.502.20.1.899 | ColumnniduRingInst3masterRemoteB | read-write | current | NID Series card u-Ring instance3 master 0: No 1: Yes |
| 1.3.6.1.4.1.4756.20.502.20.1.900 | ColumnniduRingInst3EastPortRemoteB | read-only | current | NID Series card u-Ring instance3 east port |
| 1.3.6.1.4.1.4756.20.502.20.1.901 | ColumnniduRingInst3EastEdgeRemoteB | read-write | current | NID Series card u-Ring instance3 east edge 0: No 1: Yes |
| 1.3.6.1.4.1.4756.20.502.20.1.902 | ColumnniduRingInst3WestPortRemoteB | read-only | current | NID Series card u-Ring instance3 west port |
| 1.3.6.1.4.1.4756.20.502.20.1.903 | ColumnniduRingInst3WestEdgeRemoteB | read-write | current | NID Series card u-Ring instance3 west edge 0: No 1: Yes |
| 1.3.6.1.4.1.4756.20.502.20.1.904 | ColumnniduRingInst4IDRemoteB | read-only | current | NID Series card u-Ring instance4 ID |
| 1.3.6.1.4.1.4756.20.502.20.1.905 | ColumnniduRingInst4typeRemoteB | read-only | current | NID Series card u-Ring instance4 type 0: u-Ring 1: Sub-Ring 2: u-Chain |
| 1.3.6.1.4.1.4756.20.502.20.1.906 | ColumnniduRingInst4masterRemoteB | read-write | current | NID Series card u-Ring instance4 master 0: No 1: Yes |
| 1.3.6.1.4.1.4756.20.502.20.1.907 | ColumnniduRingInst4EastPortRemoteB | read-only | current | NID Series card u-Ring instance4 east port |
| 1.3.6.1.4.1.4756.20.502.20.1.908 | ColumnniduRingInst4EastEdgeRemoteB | read-write | current | NID Series card u-Ring instance4 east edge 0: No 1: Yes |
| 1.3.6.1.4.1.4756.20.502.20.1.909 | ColumnniduRingInst4WestPortRemoteB | read-only | current | NID Series card u-Ring instance4 west port |
| 1.3.6.1.4.1.4756.20.502.20.1.910 | ColumnniduRingInst4WestEdgeRemoteB | read-write | current | NID Series card u-Ring instance4 west edge 0: No 1: Yes |
| 1.3.6.1.4.1.4756.20.502.20.1.911 | ColumnniduRingInst1IDstsRemoteB | read-only | current | NID Series card u-Ring Instance1 ID status |
| 1.3.6.1.4.1.4756.20.502.20.1.912 | ColumnniduRingInst1typestsRemoteB | read-only | current | NID Series card u-Ring Type status |
| 1.3.6.1.4.1.4756.20.502.20.1.913 | ColumnniduRingInst1rolestsRemoteB | read-only | current | NID Series card u-Ring Role status |
| 1.3.6.1.4.1.4756.20.502.20.1.914 | ColumnniduRingInst1EastPortstsRemoteB | read-only | current | NID Series card u-Ring East port status |
| 1.3.6.1.4.1.4756.20.502.20.1.915 | ColumnniduRingInst1EaststsRemoteB | read-only | current | NID Series card u-Ring East status |
| 1.3.6.1.4.1.4756.20.502.20.1.916 | ColumnniduRingInst1EastEdgestsRemoteB | read-only | current | NID Series card u-Ring East edge status |
| 1.3.6.1.4.1.4756.20.502.20.1.917 | ColumnniduRingInst1WestPortstsRemoteB | read-only | current | NID Series card u-Ring West edge status |
| 1.3.6.1.4.1.4756.20.502.20.1.918 | ColumnniduRingInst1WeststsRemoteB | read-only | current | NID Series card u-Ring West status |
| 1.3.6.1.4.1.4756.20.502.20.1.919 | ColumnniduRingInst1WestEdgestsRemoteB | read-only | current | NID Series card u-Ring West status |
| 1.3.6.1.4.1.4756.20.502.20.1.920 | ColumnniduRingInst1healthystsRemoteB | read-only | current | NID Series card u-Ring healthy status None Fine Fault |
| 1.3.6.1.4.1.4756.20.502.20.1.921 | ColumnniduRingInst2IDstsRemoteB | read-only | current | NID Series card u-Ring Instance2 ID status |
| 1.3.6.1.4.1.4756.20.502.20.1.922 | ColumnniduRingInst2typestsRemoteB | read-only | current | NID Series card u-Ring Type status |
| 1.3.6.1.4.1.4756.20.502.20.1.923 | ColumnniduRingInst2rolestsRemoteB | read-only | current | NID Series card u-Ring Role status |
| 1.3.6.1.4.1.4756.20.502.20.1.924 | ColumnniduRingInst2EastPortstsRemoteB | read-only | current | NID Series card u-Ring East port status |
| 1.3.6.1.4.1.4756.20.502.20.1.925 | ColumnniduRingInst2EaststsRemoteB | read-only | current | NID Series card u-Ring East status |
| 1.3.6.1.4.1.4756.20.502.20.1.926 | ColumnniduRingInst2EastEdgestsRemoteB | read-only | current | NID Series card u-Ring East edge status |
| 1.3.6.1.4.1.4756.20.502.20.1.927 | ColumnniduRingInst2WestPortstsRemoteB | read-only | current | NID Series card u-Ring West edge status |
| 1.3.6.1.4.1.4756.20.502.20.1.928 | ColumnniduRingInst2WeststsRemoteB | read-only | current | NID Series card u-Ring West status |
| 1.3.6.1.4.1.4756.20.502.20.1.929 | ColumnniduRingInst2WestEdgestsRemoteB | read-only | current | NID Series card u-Ring West status |
| 1.3.6.1.4.1.4756.20.502.20.1.930 | ColumnniduRingInst2healthystsRemoteB | read-only | current | NID Series card u-Ring healthy status None Fine Fault |
| 1.3.6.1.4.1.4756.20.502.20.1.931 | ColumnniduRingInst3IDstsRemoteB | read-only | current | NID Series card u-Ring Instance3 ID status |
| 1.3.6.1.4.1.4756.20.502.20.1.932 | ColumnniduRingInst3typestsRemoteB | read-only | current | NID Series card u-Ring Type status |
| 1.3.6.1.4.1.4756.20.502.20.1.933 | ColumnniduRingInst3rolestsRemoteB | read-only | current | NID Series card u-Ring Role status |
| 1.3.6.1.4.1.4756.20.502.20.1.934 | ColumnniduRingInst3EastPortstsRemoteB | read-only | current | NID Series card u-Ring East port status |
| 1.3.6.1.4.1.4756.20.502.20.1.935 | ColumnniduRingInst3EaststsRemoteB | read-only | current | NID Series card u-Ring East status |
| 1.3.6.1.4.1.4756.20.502.20.1.936 | ColumnniduRingInst3EastEdgestsRemoteB | read-only | current | NID Series card u-Ring East edge status |
| 1.3.6.1.4.1.4756.20.502.20.1.937 | ColumnniduRingInst3WestPortstsRemoteB | read-only | current | NID Series card u-Ring West edge status |
| 1.3.6.1.4.1.4756.20.502.20.1.938 | ColumnniduRingInst3WeststsRemoteB | read-only | current | NID Series card u-Ring West status |
| 1.3.6.1.4.1.4756.20.502.20.1.939 | ColumnniduRingInst3WestEdgestsRemoteB | read-only | current | NID Series card u-Ring West status |
| 1.3.6.1.4.1.4756.20.502.20.1.940 | ColumnniduRingInst3healthystsRemoteB | read-only | current | NID Series card u-Ring healthy status None Fine Fault |
| 1.3.6.1.4.1.4756.20.502.20.1.941 | ColumnniduRingInst4IDstsRemoteB | read-only | current | NID Series card u-Ring Instance4 ID status |
| 1.3.6.1.4.1.4756.20.502.20.1.942 | ColumnniduRingInst4typestsRemoteB | read-only | current | NID Series card u-Ring Type status |
| 1.3.6.1.4.1.4756.20.502.20.1.943 | ColumnniduRingInst4rolestsRemoteB | read-only | current | NID Series card u-Ring Role status |
| 1.3.6.1.4.1.4756.20.502.20.1.944 | ColumnniduRingInst4EastPortstsRemoteB | read-only | current | NID Series card u-Ring East port status |
| 1.3.6.1.4.1.4756.20.502.20.1.945 | ColumnniduRingInst4EaststsRemoteB | read-only | current | NID Series card u-Ring East status |
| 1.3.6.1.4.1.4756.20.502.20.1.946 | ColumnniduRingInst4EastEdgestsRemoteB | read-only | current | NID Series card u-Ring East edge status |
| 1.3.6.1.4.1.4756.20.502.20.1.947 | ColumnniduRingInst4WestPortstsRemoteB | read-only | current | NID Series card u-Ring West edge status |
| 1.3.6.1.4.1.4756.20.502.20.1.948 | ColumnniduRingInst4WeststsRemoteB | read-only | current | NID Series card u-Ring West status |
| 1.3.6.1.4.1.4756.20.502.20.1.949 | ColumnniduRingInst4WestEdgestsRemoteB | read-only | current | NID Series card u-Ring West status |
| 1.3.6.1.4.1.4756.20.502.20.1.950 | ColumnniduRingInst4healthystsRemoteB | read-only | current | NID Series card u-Ring healthy status None Fine Fault |
| 1.3.6.1.4.1.4756.20.502.20.1.951 | ColumnnidSTPProtocolVersionRemoteB | read-write | current | NID Series card STP Bridge Configuration: Basic Settings - Protocol Version 0: STP 1: RSTP 2: MSTP |
| 1.3.6.1.4.1.4756.20.502.20.1.952 | ColumnnidSTPBridgePriorityRemoteB | read-write | current | NID Series card STP Bridge Configuration: Basic Settings - Bridge Priority 0: 0 1: 4096 2: 8192 3: 12288 4: 16384 5: 20480 6: 24576 7: 28672 8: 32768 9: 36864 … |
| 1.3.6.1.4.1.4756.20.502.20.1.953 | ColumnnidSTPForwardDelayRemoteB | read-write | current | NID Series card STP Bridge Configuration: Basic Settings - Forward Delay |
| 1.3.6.1.4.1.4756.20.502.20.1.954 | ColumnnidSTPMaxAgeRemoteB | read-write | current | NID Series card STP Bridge Configuration: Basic Settings - Max Age |
| 1.3.6.1.4.1.4756.20.502.20.1.955 | ColumnnidSTPMaximumHopCountRemoteB | read-write | current | NID Series card STP Bridge Configuration: Basic Settings - Maximum Hop Count |
| 1.3.6.1.4.1.4756.20.502.20.1.956 | ColumnnidSTPTransmitHoldCountRemoteB | read-write | current | NID Series card STP Bridge Configuration: Basic Settings - Transmit Hold Count |
| 1.3.6.1.4.1.4756.20.502.20.1.957 | ColumnnidSTPEdgePortBPDUFilteringRemoteB | read-write | current | NID Series card STP Bridge Configuration: Advanced Settings - Edge Port BPDU Filtering 0: Off 1: On |
| 1.3.6.1.4.1.4756.20.502.20.1.958 | ColumnnidSTPEdgePortBPDUGuardRemoteB | read-write | current | NID Series card STP Bridge Configuration: Advanced Settings - Edge Port BPDU Guard 0: Off 1: On |
| 1.3.6.1.4.1.4756.20.502.20.1.959 | ColumnnidSTPPortErrorRecoveryTimeoutRemoteB | read-write | current | NID Series card STP Bridge Configuration: Advanced Settings - Port Error Recovery Timeout 0: Off 1: On |
| 1.3.6.1.4.1.4756.20.502.20.1.960 | ColumnnidMSTIConfigurationNameRemoteB | read-write | current | NID Series card MSTI Configuration: Configuration Identification - Configuration Name |
| 1.3.6.1.4.1.4756.20.502.20.1.961 | ColumnnidMSTIConfigurationRevisionRemoteB | read-write | current | NID Series card MSTI Configuration: Configuration Identification - Configuration Revision |
| 1.3.6.1.4.1.4756.20.502.20.1.962 | ColumnnidMSTI1VLANsMappingRemoteB | read-write | current | NID Series card MSTI Configuration: MSTI Mapping - MSTI 1 |
| 1.3.6.1.4.1.4756.20.502.20.1.963 | ColumnnidMSTI2VLANsMappingRemoteB | read-write | current | NID Series card MSTI Configuration: MSTI Mapping - MSTI 2 |
| 1.3.6.1.4.1.4756.20.502.20.1.964 | ColumnnidMSTI3VLANsMappingRemoteB | read-write | current | NID Series card MSTI Configuration: MSTI Mapping - MSTI 3 |
| 1.3.6.1.4.1.4756.20.502.20.1.965 | ColumnnidMSTI4VLANsMappingRemoteB | read-write | current | NID Series card MSTI Configuration: MSTI Mapping - MSTI 4 |
| 1.3.6.1.4.1.4756.20.502.20.1.966 | ColumnnidMSTI5VLANsMappingRemoteB | read-write | current | NID Series card MSTI Configuration: MSTI Mapping - MSTI 5 |
| 1.3.6.1.4.1.4756.20.502.20.1.967 | ColumnnidMSTI6VLANsMappingRemoteB | read-write | current | NID Series card MSTI Configuration: MSTI Mapping - MSTI 6 |
| 1.3.6.1.4.1.4756.20.502.20.1.968 | ColumnnidMSTI7VLANsMappingRemoteB | read-write | current | NID Series card MSTI Configuration: MSTI Mapping - MSTI 7 |
| 1.3.6.1.4.1.4756.20.502.20.1.969 | ColumnnidMSTI8VLANsMappingRemoteB | read-write | current | NID Series card MSTI Configuration: MSTI Mapping - MSTI 8 |
| 1.3.6.1.4.1.4756.20.502.20.1.970 | ColumnnidMSTI9VLANsMappingRemoteB | read-write | current | NID Series card MSTI Configuration: MSTI Mapping - MSTI 9 |
| 1.3.6.1.4.1.4756.20.502.20.1.971 | ColumnnidMSTI10VLANsMappingRemoteB | read-write | current | NID Series card MSTI Configuration: MSTI Mapping - MSTI 10 |
| 1.3.6.1.4.1.4756.20.502.20.1.972 | ColumnnidMSTI11VLANsMappingRemoteB | read-write | current | NID Series card MSTI Configuration: MSTI Mapping - MSTI 11 |
| 1.3.6.1.4.1.4756.20.502.20.1.973 | ColumnnidMSTI12VLANsMappingRemoteB | read-write | current | NID Series card MSTI Configuration: MSTI Mapping - MSTI 12 |
| 1.3.6.1.4.1.4756.20.502.20.1.974 | ColumnnidMSTI13VLANsMappingRemoteB | read-write | current | NID Series card MSTI Configuration: MSTI Mapping - MSTI 13 |
| 1.3.6.1.4.1.4756.20.502.20.1.975 | ColumnnidMSTI14VLANsMappingRemoteB | read-write | current | NID Series card MSTI Configuration: MSTI Mapping - MSTI 14 |
| 1.3.6.1.4.1.4756.20.502.20.1.976 | ColumnnidMSTI15VLANsMappingRemoteB | read-write | current | NID Series card MSTI Configuration: MSTI Mapping - MSTI 15 |
| 1.3.6.1.4.1.4756.20.502.20.1.977 | ColumnnidCISTAggregatedSTPEnabledRemoteB | read-write | current | NID Series card STP CIST Port Configuration: CIST Aggregated Port Configuration - STP Enabled |
| 1.3.6.1.4.1.4756.20.502.20.1.978 | ColumnnidCISTAggregatedPathCostRemoteB | read-write | current | NID Series card STP CIST Port Configuration: CIST Aggregated Port Configuration - Path Cost Valid values are in the range 0 to 200000000. Setting 0 means Auto … |
| 1.3.6.1.4.1.4756.20.502.20.1.979 | ColumnnidCISTAggregatedPriorityRemoteB | read-write | current | NID Series card STP CIST Port Configuration: CIST Aggregated Port Configuration - Priority |
| 1.3.6.1.4.1.4756.20.502.20.1.980 | ColumnnidCISTAggregatedAdminEdgeRemoteB | read-write | current | NID Series card STP CIST Port Configuration: CIST Aggregated Port Configuration - STP Enabled 0: Non-edge 1: Edge |
| 1.3.6.1.4.1.4756.20.502.20.1.981 | ColumnnidCISTAggregatedAutoEdgeRemoteB | read-write | current | NID Series card STP CIST Port Configuration: CIST Aggregated Port Configuration - Auto Edge 0: Non-edge 1: Edge |
| 1.3.6.1.4.1.4756.20.502.20.1.982 | ColumnnidCISTAggregatedRestrictedRoleRemoteB | read-write | current | NID Series card STP CIST Port Configuration: CIST Aggregated Port Configuration - Restricted Role 0: Non-edge 1: Edge |
| 1.3.6.1.4.1.4756.20.502.20.1.983 | ColumnnidCISTAggregatedRestrictedTCNRemoteB | read-write | current | NID Series card STP CIST Port Configuration: CIST Aggregated Port Configuration - Restricted TCN 0: Non-edge 1: Edge |
| 1.3.6.1.4.1.4756.20.502.20.1.984 | ColumnnidCISTAggregatedBPDUGuardRemoteB | read-write | current | NID Series card STP CIST Port Configuration: CIST Aggregated Port Configuration - BPDU Guard 0: Non-edge 1: Edge |
| 1.3.6.1.4.1.4756.20.502.20.1.985 | ColumnnidCISTAggregatedPointToPointRemoteB | read-write | current | NID Series card STP CIST Port Configuration: CIST Aggregated Port Configuration - Point-to-point 0: Forced True 1: Forced False 2: Auto |
| 1.3.6.1.4.1.4756.20.502.20.1.986 | ColumnnidCISTPort1STPEnabledRemoteB | read-write | current | NID Series card STP CIST Port Configuration: CIST Normal Port1 Configuration - STP Enabled |
| 1.3.6.1.4.1.4756.20.502.20.1.987 | ColumnnidCISTPort1PathCostRemoteB | read-write | current | NID Series card STP CIST Port Configuration: CIST Normal Port1 Configuration - Path Cost Valid values are in the range 0 to 200000000. Setting 0 means Auto pat… |
| 1.3.6.1.4.1.4756.20.502.20.1.988 | ColumnnidCISTPort1PriorityRemoteB | read-write | current | NID Series card STP CIST Port Configuration: CIST Normal Port1 Configuration - Priority |
| 1.3.6.1.4.1.4756.20.502.20.1.989 | ColumnnidCISTPort1AdminEdgeRemoteB | read-write | current | NID Series card STP CIST Port Configuration: CIST Normal Port1 Configuration - STP Enabled 0: Non-edge 1: Edge |
| 1.3.6.1.4.1.4756.20.502.20.1.990 | ColumnnidCISTPort1AutoEdgeRemoteB | read-write | current | NID Series card STP CIST Port Configuration: CIST Normal Port1 Configuration - Auto Edge 0: Non-edge 1: Edge |
| 1.3.6.1.4.1.4756.20.502.20.1.991 | ColumnnidCISTPort1RestrictedRoleRemoteB | read-write | current | NID Series card STP CIST Port Configuration: CIST Normal Port1 Configuration - Restricted Role 0: Non-edge 1: Edge |
| 1.3.6.1.4.1.4756.20.502.20.1.992 | ColumnnidCISTPort1RestrictedTCNRemoteB | read-write | current | NID Series card STP CIST Port Configuration: CIST Normal Port1 Configuration - Restricted TCN 0: Non-edge 1: Edge |
| 1.3.6.1.4.1.4756.20.502.20.1.993 | ColumnnidCISTPort1BPDUGuardRemoteB | read-write | current | NID Series card STP CIST Port Configuration: CIST Normal Port1 Configuration - BPDU Guard 0: Non-edge 1: Edge |
| 1.3.6.1.4.1.4756.20.502.20.1.994 | ColumnnidCISTPort1PointToPointRemoteB | read-write | current | NID Series card STP CIST Port Configuration: CIST Normal Port1 Configuration - Point-to-point 0: Forced True 1: Forced False 2: Auto |
| 1.3.6.1.4.1.4756.20.502.20.1.995 | ColumnnidCISTPort2STPEnabledRemoteB | read-write | current | NID Series card STP CIST Port Configuration: CIST Normal Port2 Configuration - STP Enabled |
| 1.3.6.1.4.1.4756.20.502.20.1.996 | ColumnnidCISTPort2PathCostRemoteB | read-write | current | NID Series card STP CIST Port Configuration: CIST Normal Port2 Configuration - Path Cost Valid values are in the range 0 to 200000000. Setting 0 means Auto pat… |
| 1.3.6.1.4.1.4756.20.502.20.1.997 | ColumnnidCISTPort2PriorityRemoteB | read-write | current | NID Series card STP CIST Port Configuration: CIST Normal Port2 Configuration - Priority |
| 1.3.6.1.4.1.4756.20.502.20.1.998 | ColumnnidCISTPort2AdminEdgeRemoteB | read-write | current | NID Series card STP CIST Port Configuration: CIST Normal Port2 Configuration - STP Enabled 0: Non-edge 1: Edge |
| 1.3.6.1.4.1.4756.20.502.20.1.999 | ColumnnidCISTPort2AutoEdgeRemoteB | read-write | current | NID Series card STP CIST Port Configuration: CIST Normal Port2 Configuration - Auto Edge 0: Non-edge 1: Edge |
| 1.3.6.1.4.1.4756.20.502.20.1.1000 | ColumnnidCISTPort2RestrictedRoleRemoteB | read-write | current | NID Series card STP CIST Port Configuration: CIST Normal Port2 Configuration - Restricted Role 0: Non-edge 1: Edge |
| 1.3.6.1.4.1.4756.20.502.20.1.1001 | ColumnnidCISTPort2RestrictedTCNRemoteB | read-write | current | NID Series card STP CIST Port Configuration: CIST Normal Port2 Configuration - Restricted TCN 0: Non-edge 1: Edge |
| 1.3.6.1.4.1.4756.20.502.20.1.1002 | ColumnnidCISTPort2BPDUGuardRemoteB | read-write | current | NID Series card STP CIST Port Configuration: CIST Normal Port2 Configuration - BPDU Guard 0: Non-edge 1: Edge |
| 1.3.6.1.4.1.4756.20.502.20.1.1003 | ColumnnidCISTPort2PointToPointRemoteB | read-write | current | NID Series card STP CIST Port Configuration: CIST Normal Port2 Configuration - Point-to-point 0: Forced True 1: Forced False 2: Auto |
| 1.3.6.1.4.1.4756.20.502.20.1.1004 | ColumnnidCISTPort3STPEnabledRemoteB | read-write | current | NID Series card STP CIST Port Configuration: CIST Normal Port3 Configuration - STP Enabled |
| 1.3.6.1.4.1.4756.20.502.20.1.1005 | ColumnnidCISTPort3PathCostRemoteB | read-write | current | NID Series card STP CIST Port Configuration: CIST Normal Port3 Configuration - Path Cost Valid values are in the range 0 to 200000000. Setting 0 means Auto pat… |
| 1.3.6.1.4.1.4756.20.502.20.1.1006 | ColumnnidCISTPort3PriorityRemoteB | read-write | current | NID Series card STP CIST Port Configuration: CIST Normal Port3 Configuration - Priority |
| 1.3.6.1.4.1.4756.20.502.20.1.1007 | ColumnnidCISTPort3AdminEdgeRemoteB | read-write | current | NID Series card STP CIST Port Configuration: CIST Normal Port3 Configuration - STP Enabled 0: Non-edge 1: Edge |
| 1.3.6.1.4.1.4756.20.502.20.1.1008 | ColumnnidCISTPort3AutoEdgeRemoteB | read-write | current | NID Series card STP CIST Port Configuration: CIST Normal Port3 Configuration - Auto Edge 0: Non-edge 1: Edge |
| 1.3.6.1.4.1.4756.20.502.20.1.1009 | ColumnnidCISTPort3RestrictedRoleRemoteB | read-write | current | NID Series card STP CIST Port Configuration: CIST Normal Port3 Configuration - Restricted Role 0: Non-edge 1: Edge |
| 1.3.6.1.4.1.4756.20.502.20.1.1010 | ColumnnidCISTPort3RestrictedTCNRemoteB | read-write | current | NID Series card STP CIST Port Configuration: CIST Normal Port3 Configuration - Restricted TCN 0: Non-edge 1: Edge |
| 1.3.6.1.4.1.4756.20.502.20.1.1011 | ColumnnidCISTPort3BPDUGuardRemoteB | read-write | current | NID Series card STP CIST Port Configuration: CIST Normal Port3 Configuration - BPDU Guard 0: Non-edge 1: Edge |
| 1.3.6.1.4.1.4756.20.502.20.1.1012 | ColumnnidCISTPort3PointToPointRemoteB | read-write | current | NID Series card STP CIST Port Configuration: CIST Normal Port3 Configuration - Point-to-point 0: Forced True 1: Forced False 2: Auto |
| 1.3.6.1.4.1.4756.20.502.20.1.1013 | ColumnnidCISTPort4STPEnabledRemoteB | read-write | current | NID Series card STP CIST Port Configuration: CIST Normal Port4 Configuration - STP Enabled |
| 1.3.6.1.4.1.4756.20.502.20.1.1014 | ColumnnidCISTPort4PathCostRemoteB | read-write | current | NID Series card STP CIST Port Configuration: CIST Normal Port4 Configuration - Path Cost Valid values are in the range 0 to 200000000. Setting 0 means Auto pat… |
| 1.3.6.1.4.1.4756.20.502.20.1.1015 | ColumnnidCISTPort4PriorityRemoteB | read-write | current | NID Series card STP CIST Port Configuration: CIST Normal Port4 Configuration - Priority |
| 1.3.6.1.4.1.4756.20.502.20.1.1016 | ColumnnidCISTPort4AdminEdgeRemoteB | read-write | current | NID Series card STP CIST Port Configuration: CIST Normal Port4 Configuration - STP Enabled 0: Non-edge 1: Edge |
| 1.3.6.1.4.1.4756.20.502.20.1.1017 | ColumnnidCISTPort4AutoEdgeRemoteB | read-write | current | NID Series card STP CIST Port Configuration: CIST Normal Port4 Configuration - Auto Edge 0: Non-edge 1: Edge |
| 1.3.6.1.4.1.4756.20.502.20.1.1018 | ColumnnidCISTPort4RestrictedRoleRemoteB | read-write | current | NID Series card STP CIST Port Configuration: CIST Normal Port4 Configuration - Restricted Role 0: Non-edge 1: Edge |
| 1.3.6.1.4.1.4756.20.502.20.1.1019 | ColumnnidCISTPort4RestrictedTCNRemoteB | read-write | current | NID Series card STP CIST Port Configuration: CIST Normal Port4 Configuration - Restricted TCN 0: Non-edge 1: Edge |
| 1.3.6.1.4.1.4756.20.502.20.1.1020 | ColumnnidCISTPort4BPDUGuardRemoteB | read-write | current | NID Series card STP CIST Port Configuration: CIST Normal Port4 Configuration - BPDU Guard 0: Non-edge 1: Edge |
| 1.3.6.1.4.1.4756.20.502.20.1.1021 | ColumnnidCISTPort4PointToPointRemoteB | read-write | current | NID Series card STP CIST Port Configuration: CIST Normal Port4 Configuration - Point-to-point 0: Forced True 1: Forced False 2: Auto |
| 1.3.6.1.4.1.4756.20.502.20.1.1022 | ColumnnidCISTPort5STPEnabledRemoteB | read-write | current | NID Series card STP CIST Port Configuration: CIST Normal Port5 Configuration - STP Enabled |
| 1.3.6.1.4.1.4756.20.502.20.1.1023 | ColumnnidCISTPort5PathCostRemoteB | read-write | current | NID Series card STP CIST Port Configuration: CIST Normal Port5 Configuration - Path Cost Valid values are in the range 0 to 200000000. Setting 0 means Auto pat… |
| 1.3.6.1.4.1.4756.20.502.20.1.1024 | ColumnnidCISTPort5PriorityRemoteB | read-write | current | NID Series card STP CIST Port Configuration: CIST Normal Port5 Configuration - Priority |
| 1.3.6.1.4.1.4756.20.502.20.1.1025 | ColumnnidCISTPort5AdminEdgeRemoteB | read-write | current | NID Series card STP CIST Port Configuration: CIST Normal Port5 Configuration - STP Enabled 0: Non-edge 1: Edge |
| 1.3.6.1.4.1.4756.20.502.20.1.1026 | ColumnnidCISTPort5AutoEdgeRemoteB | read-write | current | NID Series card STP CIST Port Configuration: CIST Normal Port5 Configuration - Auto Edge 0: Non-edge 1: Edge |
| 1.3.6.1.4.1.4756.20.502.20.1.1027 | ColumnnidCISTPort5RestrictedRoleRemoteB | read-write | current | NID Series card STP CIST Port Configuration: CIST Normal Port5 Configuration - Restricted Role 0: Non-edge 1: Edge |
| 1.3.6.1.4.1.4756.20.502.20.1.1028 | ColumnnidCISTPort5RestrictedTCNRemoteB | read-write | current | NID Series card STP CIST Port Configuration: CIST Normal Port5 Configuration - Restricted TCN 0: Non-edge 1: Edge |
| 1.3.6.1.4.1.4756.20.502.20.1.1029 | ColumnnidCISTPort5BPDUGuardRemoteB | read-write | current | NID Series card STP CIST Port Configuration: CIST Normal Port5 Configuration - BPDU Guard 0: Non-edge 1: Edge |
| 1.3.6.1.4.1.4756.20.502.20.1.1030 | ColumnnidCISTPort5PointToPointRemoteB | read-write | current | NID Series card STP CIST Port Configuration: CIST Normal Port5 Configuration - Point-to-point 0: Forced True 1: Forced False 2: Auto |
| 1.3.6.1.4.1.4756.20.502.20.1.1031 | ColumnnidCISTPort6STPEnabledRemoteB | read-write | current | NID Series card STP CIST Port Configuration: CIST Normal Port6 Configuration - STP Enabled |
| 1.3.6.1.4.1.4756.20.502.20.1.1032 | ColumnnidCISTPort6PathCostRemoteB | read-write | current | NID Series card STP CIST Port Configuration: CIST Normal Port6 Configuration - Path Cost Valid values are in the range 0 to 200000000. Setting 0 means Auto pat… |
| 1.3.6.1.4.1.4756.20.502.20.1.1033 | ColumnnidCISTPort6PriorityRemoteB | read-write | current | NID Series card STP CIST Port Configuration: CIST Normal Port6 Configuration - Priority |
| 1.3.6.1.4.1.4756.20.502.20.1.1034 | ColumnnidCISTPort6AdminEdgeRemoteB | read-write | current | NID Series card STP CIST Port Configuration: CIST Normal Port6 Configuration - STP Enabled 0: Non-edge 1: Edge |
| 1.3.6.1.4.1.4756.20.502.20.1.1035 | ColumnnidCISTPort6AutoEdgeRemoteB | read-write | current | NID Series card STP CIST Port Configuration: CIST Normal Port6 Configuration - Auto Edge 0: Non-edge 1: Edge |
| 1.3.6.1.4.1.4756.20.502.20.1.1036 | ColumnnidCISTPort6RestrictedRoleRemoteB | read-write | current | NID Series card STP CIST Port Configuration: CIST Normal Port6 Configuration - Restricted Role 0: Non-edge 1: Edge |
| 1.3.6.1.4.1.4756.20.502.20.1.1037 | ColumnnidCISTPort6RestrictedTCNRemoteB | read-write | current | NID Series card STP CIST Port Configuration: CIST Normal Port6 Configuration - Restricted TCN 0: Non-edge 1: Edge |
| 1.3.6.1.4.1.4756.20.502.20.1.1038 | ColumnnidCISTPort6BPDUGuardRemoteB | read-write | current | NID Series card STP CIST Port Configuration: CIST Normal Port6 Configuration - BPDU Guard 0: Non-edge 1: Edge |
| 1.3.6.1.4.1.4756.20.502.20.1.1039 | ColumnnidCISTPort6PointToPointRemoteB | read-write | current | NID Series card STP CIST Port Configuration: CIST Normal Port6 Configuration - Point-to-point 0: Forced True 1: Forced False 2: Auto |
| 1.3.6.1.4.1.4756.20.502.20.1.1040 | ColumnnidCISTPort7STPEnabledRemoteB | read-write | current | NID Series card STP CIST Port Configuration: CIST Normal Port7 Configuration - STP Enabled |
| 1.3.6.1.4.1.4756.20.502.20.1.1041 | ColumnnidCISTPort7PathCostRemoteB | read-write | current | NID Series card STP CIST Port Configuration: CIST Normal Port7 Configuration - Path Cost Valid values are in the range 0 to 200000000. Setting 0 means Auto pat… |
| 1.3.6.1.4.1.4756.20.502.20.1.1042 | ColumnnidCISTPort7PriorityRemoteB | read-write | current | NID Series card STP CIST Port Configuration: CIST Normal Port7 Configuration - Priority |
| 1.3.6.1.4.1.4756.20.502.20.1.1043 | ColumnnidCISTPort7AdminEdgeRemoteB | read-write | current | NID Series card STP CIST Port Configuration: CIST Normal Port7 Configuration - STP Enabled 0: Non-edge 1: Edge |
| 1.3.6.1.4.1.4756.20.502.20.1.1044 | ColumnnidCISTPort7AutoEdgeRemoteB | read-write | current | NID Series card STP CIST Port Configuration: CIST Normal Port7 Configuration - Auto Edge 0: Non-edge 1: Edge |
| 1.3.6.1.4.1.4756.20.502.20.1.1045 | ColumnnidCISTPort7RestrictedRoleRemoteB | read-write | current | NID Series card STP CIST Port Configuration: CIST Normal Port7 Configuration - Restricted Role 0: Non-edge 1: Edge |
| 1.3.6.1.4.1.4756.20.502.20.1.1046 | ColumnnidCISTPort7RestrictedTCNRemoteB | read-write | current | NID Series card STP CIST Port Configuration: CIST Normal Port7 Configuration - Restricted TCN 0: Non-edge 1: Edge |
| 1.3.6.1.4.1.4756.20.502.20.1.1047 | ColumnnidCISTPort7BPDUGuardRemoteB | read-write | current | NID Series card STP CIST Port Configuration: CIST Normal Port7 Configuration - BPDU Guard 0: Non-edge 1: Edge |
| 1.3.6.1.4.1.4756.20.502.20.1.1048 | ColumnnidCISTPort7PointToPointRemoteB | read-write | current | NID Series card STP CIST Port Configuration: CIST Normal Port7 Configuration - Point-to-point 0: Forced True 1: Forced False 2: Auto |
| 1.3.6.1.4.1.4756.20.502.20.1.1049 | ColumnnidCISTPort8STPEnabledRemoteB | read-write | current | NID Series card STP CIST Port Configuration: CIST Normal Port8 Configuration - STP Enabled |
| 1.3.6.1.4.1.4756.20.502.20.1.1050 | ColumnnidCISTPort8PathCostRemoteB | read-write | current | NID Series card STP CIST Port Configuration: CIST Normal Port8 Configuration - Path Cost Valid values are in the range 0 to 200000000. Setting 0 means Auto pat… |
| 1.3.6.1.4.1.4756.20.502.20.1.1051 | ColumnnidCISTPort8PriorityRemoteB | read-write | current | NID Series card STP CIST Port Configuration: CIST Normal Port8 Configuration - Priority |
| 1.3.6.1.4.1.4756.20.502.20.1.1052 | ColumnnidCISTPort8AdminEdgeRemoteB | read-write | current | NID Series card STP CIST Port Configuration: CIST Normal Port8 Configuration - STP Enabled 0: Non-edge 1: Edge |
| 1.3.6.1.4.1.4756.20.502.20.1.1053 | ColumnnidCISTPort8AutoEdgeRemoteB | read-write | current | NID Series card STP CIST Port Configuration: CIST Normal Port8 Configuration - Auto Edge 0: Non-edge 1: Edge |
| 1.3.6.1.4.1.4756.20.502.20.1.1054 | ColumnnidCISTPort8RestrictedRoleRemoteB | read-write | current | NID Series card STP CIST Port Configuration: CIST Normal Port8 Configuration - Restricted Role 0: Non-edge 1: Edge |
| 1.3.6.1.4.1.4756.20.502.20.1.1055 | ColumnnidCISTPort8RestrictedTCNRemoteB | read-write | current | NID Series card STP CIST Port Configuration: CIST Normal Port8 Configuration - Restricted TCN 0: Non-edge 1: Edge |
| 1.3.6.1.4.1.4756.20.502.20.1.1056 | ColumnnidCISTPort8BPDUGuardRemoteB | read-write | current | NID Series card STP CIST Port Configuration: CIST Normal Port8 Configuration - BPDU Guard 0: Non-edge 1: Edge |
| 1.3.6.1.4.1.4756.20.502.20.1.1057 | ColumnnidCISTPort8PointToPointRemoteB | read-write | current | NID Series card STP CIST Port Configuration: CIST Normal Port8 Configuration - Point-to-point 0: Forced True 1: Forced False 2: Auto |
| 1.3.6.1.4.1.4756.20.502.20.1.1058 | ColumnnidMSTI1AggregatedPathCostRemoteB | read-write | current | NID Series card MSTI Port Configuration: MSTI1 Aggregated Ports Configuration - Path Cost Valid values are in the range 0 to 200000000. Setting 0 means Auto pa… |
| 1.3.6.1.4.1.4756.20.502.20.1.1059 | ColumnnidMSTI1AggregatedPriorityRemoteB | read-write | current | NID Series card MSTI Port Configuration: MSTI1 Aggregated Ports Configuration - Priority |
| 1.3.6.1.4.1.4756.20.502.20.1.1060 | ColumnnidMSTI1Port1PathCostRemoteB | read-write | current | NID Series card MSTI Port Configuration: MSTI1 Normal Port1 Configuration - Path Cost Valid values are in the range 0 to 200000000. Setting 0 means Auto path c… |
| 1.3.6.1.4.1.4756.20.502.20.1.1061 | ColumnnidMSTI1Port1PriorityRemoteB | read-write | current | NID Series card MSTI Port Configuration: MSTI1 Normal Port1 Configuration - Priority |
| 1.3.6.1.4.1.4756.20.502.20.1.1062 | ColumnnidMSTI1Port2PathCostRemoteB | read-write | current | NID Series card MSTI Port Configuration: MSTI1 Normal Port2 Configuration - Path Cost Valid values are in the range 0 to 200000000. Setting 0 means Auto path c… |
| 1.3.6.1.4.1.4756.20.502.20.1.1063 | ColumnnidMSTI1Port2PriorityRemoteB | read-write | current | NID Series card MSTI Port Configuration: MSTI1 Normal Port2 Configuration - Priority |
| 1.3.6.1.4.1.4756.20.502.20.1.1064 | ColumnnidMSTI1Port3PathCostRemoteB | read-write | current | NID Series card MSTI Port Configuration: MSTI1 Normal Port3 Configuration - Path Cost Valid values are in the range 0 to 200000000. Setting 0 means Auto path c… |
| 1.3.6.1.4.1.4756.20.502.20.1.1065 | ColumnnidMSTI1Port3PriorityRemoteB | read-write | current | NID Series card MSTI Port Configuration: MSTI1 Normal Port3 Configuration - Priority |
| 1.3.6.1.4.1.4756.20.502.20.1.1066 | ColumnnidMSTI1Port4PathCostRemoteB | read-write | current | NID Series card MSTI Port Configuration: MSTI1 Normal Port4 Configuration - Path Cost Valid values are in the range 0 to 200000000. Setting 0 means Auto path c… |
| 1.3.6.1.4.1.4756.20.502.20.1.1067 | ColumnnidMSTI1Port4PriorityRemoteB | read-write | current | NID Series card MSTI Port Configuration: MSTI1 Normal Port4 Configuration - Priority |
| 1.3.6.1.4.1.4756.20.502.20.1.1068 | ColumnnidMSTI1Port5PathCostRemoteB | read-write | current | NID Series card MSTI Port Configuration: MSTI1 Normal Port5 Configuration - Path Cost Valid values are in the range 0 to 200000000. Setting 0 means Auto path c… |
| 1.3.6.1.4.1.4756.20.502.20.1.1069 | ColumnnidMSTI1Port5PriorityRemoteB | read-write | current | NID Series card MSTI Port Configuration: MSTI1 Normal Port5 Configuration - Priority |
| 1.3.6.1.4.1.4756.20.502.20.1.1070 | ColumnnidMSTI1Port6PathCostRemoteB | read-write | current | NID Series card MSTI Port Configuration: MSTI1 Normal Port6 Configuration - Path Cost Valid values are in the range 0 to 200000000. Setting 0 means Auto path c… |
| 1.3.6.1.4.1.4756.20.502.20.1.1071 | ColumnnidMSTI1Port6PriorityRemoteB | read-write | current | NID Series card MSTI Port Configuration: MSTI1 Normal Port6 Configuration - Priority |
| 1.3.6.1.4.1.4756.20.502.20.1.1072 | ColumnnidMSTI1Port7PathCostRemoteB | read-write | current | NID Series card MSTI Port Configuration: MSTI1 Normal Port7 Configuration - Path Cost Valid values are in the range 0 to 200000000. Setting 0 means Auto path c… |
| 1.3.6.1.4.1.4756.20.502.20.1.1073 | ColumnnidMSTI1Port7PriorityRemoteB | read-write | current | NID Series card MSTI Port Configuration: MSTI1 Normal Port7 Configuration - Priority |
| 1.3.6.1.4.1.4756.20.502.20.1.1074 | ColumnnidMSTI1Port8PathCostRemoteB | read-write | current | NID Series card MSTI Port Configuration: MSTI1 Normal Port8 Configuration - Path Cost Valid values are in the range 0 to 200000000. Setting 0 means Auto path c… |
| 1.3.6.1.4.1.4756.20.502.20.1.1075 | ColumnnidMSTI1Port8PriorityRemoteB | read-write | current | NID Series card MSTI Port Configuration: MSTI1 Normal Port8 Configuration - Priority |
| 1.3.6.1.4.1.4756.20.502.20.1.1076 | ColumnnidMSTI2AggregatedPathCostRemoteB | read-write | current | NID Series card MSTI Port Configuration: MSTI2 Aggregated Ports Configuration - Path Cost Valid values are in the range 0 to 200000000. Setting 0 means Auto pa… |
| 1.3.6.1.4.1.4756.20.502.20.1.1077 | ColumnnidMSTI2AggregatedPriorityRemoteB | read-write | current | NID Series card MSTI Port Configuration: MSTI2 Aggregated Ports Configuration - Priority |
| 1.3.6.1.4.1.4756.20.502.20.1.1078 | ColumnnidMSTI2Port1PathCostRemoteB | read-write | current | NID Series card MSTI Port Configuration: MSTI2 Normal Port1 Configuration - Path Cost Valid values are in the range 0 to 200000000. Setting 0 means Auto path c… |
| 1.3.6.1.4.1.4756.20.502.20.1.1079 | ColumnnidMSTI2Port1PriorityRemoteB | read-write | current | NID Series card MSTI Port Configuration: MSTI2 Normal Port1 Configuration - Priority |
| 1.3.6.1.4.1.4756.20.502.20.1.1080 | ColumnnidMSTI2Port2PathCostRemoteB | read-write | current | NID Series card MSTI Port Configuration: MSTI2 Normal Port2 Configuration - Path Cost Valid values are in the range 0 to 200000000. Setting 0 means Auto path c… |
| 1.3.6.1.4.1.4756.20.502.20.1.1081 | ColumnnidMSTI2Port2PriorityRemoteB | read-write | current | NID Series card MSTI Port Configuration: MSTI2 Normal Port2 Configuration - Priority |
| 1.3.6.1.4.1.4756.20.502.20.1.1082 | ColumnnidMSTI2Port3PathCostRemoteB | read-write | current | NID Series card MSTI Port Configuration: MSTI2 Normal Port3 Configuration - Path Cost Valid values are in the range 0 to 200000000. Setting 0 means Auto path c… |
| 1.3.6.1.4.1.4756.20.502.20.1.1083 | ColumnnidMSTI2Port3PriorityRemoteB | read-write | current | NID Series card MSTI Port Configuration: MSTI2 Normal Port3 Configuration - Priority |
| 1.3.6.1.4.1.4756.20.502.20.1.1084 | ColumnnidMSTI2Port4PathCostRemoteB | read-write | current | NID Series card MSTI Port Configuration: MSTI2 Normal Port4 Configuration - Path Cost Valid values are in the range 0 to 200000000. Setting 0 means Auto path c… |
| 1.3.6.1.4.1.4756.20.502.20.1.1085 | ColumnnidMSTI2Port4PriorityRemoteB | read-write | current | NID Series card MSTI Port Configuration: MSTI2 Normal Port4 Configuration - Priority |
| 1.3.6.1.4.1.4756.20.502.20.1.1086 | ColumnnidMSTI2Port5PathCostRemoteB | read-write | current | NID Series card MSTI Port Configuration: MSTI2 Normal Port5 Configuration - Path Cost Valid values are in the range 0 to 200000000. Setting 0 means Auto path c… |
| 1.3.6.1.4.1.4756.20.502.20.1.1087 | ColumnnidMSTI2Port5PriorityRemoteB | read-write | current | NID Series card MSTI Port Configuration: MSTI2 Normal Port5 Configuration - Priority |
| 1.3.6.1.4.1.4756.20.502.20.1.1088 | ColumnnidMSTI2Port6PathCostRemoteB | read-write | current | NID Series card MSTI Port Configuration: MSTI2 Normal Port6 Configuration - Path Cost Valid values are in the range 0 to 200000000. Setting 0 means Auto path c… |
| 1.3.6.1.4.1.4756.20.502.20.1.1089 | ColumnnidMSTI2Port6PriorityRemoteB | read-write | current | NID Series card MSTI Port Configuration: MSTI2 Normal Port6 Configuration - Priority |
| 1.3.6.1.4.1.4756.20.502.20.1.1090 | ColumnnidMSTI2Port7PathCostRemoteB | read-write | current | NID Series card MSTI Port Configuration: MSTI2 Normal Port7 Configuration - Path Cost Valid values are in the range 0 to 200000000. Setting 0 means Auto path c… |
| 1.3.6.1.4.1.4756.20.502.20.1.1091 | ColumnnidMSTI2Port7PriorityRemoteB | read-write | current | NID Series card MSTI Port Configuration: MSTI2 Normal Port7 Configuration - Priority |
| 1.3.6.1.4.1.4756.20.502.20.1.1092 | ColumnnidMSTI2Port8PathCostRemoteB | read-write | current | NID Series card MSTI Port Configuration: MSTI2 Normal Port8 Configuration - Path Cost Valid values are in the range 0 to 200000000. Setting 0 means Auto path c… |
| 1.3.6.1.4.1.4756.20.502.20.1.1093 | ColumnnidMSTI2Port8PriorityRemoteB | read-write | current | NID Series card MSTI Port Configuration: MSTI2 Normal Port8 Configuration - Priority |
| 1.3.6.1.4.1.4756.20.502.20.1.1094 | ColumnnidMSTI3AggregatedPathCostRemoteB | read-write | current | NID Series card MSTI Port Configuration: MSTI3 Aggregated Ports Configuration - Path Cost Valid values are in the range 0 to 200000000. Setting 0 means Auto pa… |
| 1.3.6.1.4.1.4756.20.502.20.1.1095 | ColumnnidMSTI3AggregatedPriorityRemoteB | read-write | current | NID Series card MSTI Port Configuration: MSTI3 Aggregated Ports Configuration - Priority |
| 1.3.6.1.4.1.4756.20.502.20.1.1096 | ColumnnidMSTI3Port1PathCostRemoteB | read-write | current | NID Series card MSTI Port Configuration: MSTI3 Normal Port1 Configuration - Path Cost Valid values are in the range 0 to 200000000. Setting 0 means Auto path c… |
| 1.3.6.1.4.1.4756.20.502.20.1.1097 | ColumnnidMSTI3Port1PriorityRemoteB | read-write | current | NID Series card MSTI Port Configuration: MSTI3 Normal Port1 Configuration - Priority |
| 1.3.6.1.4.1.4756.20.502.20.1.1098 | ColumnnidMSTI3Port2PathCostRemoteB | read-write | current | NID Series card MSTI Port Configuration: MSTI3 Normal Port2 Configuration - Path Cost Valid values are in the range 0 to 200000000. Setting 0 means Auto path c… |
| 1.3.6.1.4.1.4756.20.502.20.1.1099 | ColumnnidMSTI3Port2PriorityRemoteB | read-write | current | NID Series card MSTI Port Configuration: MSTI3 Normal Port2 Configuration - Priority |
| 1.3.6.1.4.1.4756.20.502.20.1.1100 | ColumnnidMSTI3Port3PathCostRemoteB | read-write | current | NID Series card MSTI Port Configuration: MSTI1 Normal Port3 Configuration - Path Cost Valid values are in the range 0 to 200000000. Setting 0 means Auto path c… |
| 1.3.6.1.4.1.4756.20.502.20.1.1101 | ColumnnidMSTI3Port3PriorityRemoteB | read-write | current | NID Series card MSTI Port Configuration: MSTI3 Normal Port3 Configuration - Priority |
| 1.3.6.1.4.1.4756.20.502.20.1.1102 | ColumnnidMSTI3Port4PathCostRemoteB | read-write | current | NID Series card MSTI Port Configuration: MSTI3 Normal Port4 Configuration - Path Cost Valid values are in the range 0 to 200000000. Setting 0 means Auto path c… |
| 1.3.6.1.4.1.4756.20.502.20.1.1103 | ColumnnidMSTI3Port4PriorityRemoteB | read-write | current | NID Series card MSTI Port Configuration: MSTI3 Normal Port4 Configuration - Priority |
| 1.3.6.1.4.1.4756.20.502.20.1.1104 | ColumnnidMSTI3Port5PathCostRemoteB | read-write | current | NID Series card MSTI Port Configuration: MSTI3 Normal Port5 Configuration - Path Cost Valid values are in the range 0 to 200000000. Setting 0 means Auto path c… |
| 1.3.6.1.4.1.4756.20.502.20.1.1105 | ColumnnidMSTI3Port5PriorityRemoteB | read-write | current | NID Series card MSTI Port Configuration: MSTI3 Normal Port5 Configuration - Priority |
| 1.3.6.1.4.1.4756.20.502.20.1.1106 | ColumnnidMSTI3Port6PathCostRemoteB | read-write | current | NID Series card MSTI Port Configuration: MSTI3 Normal Port6 Configuration - Path Cost Valid values are in the range 0 to 200000000. Setting 0 means Auto path c… |
| 1.3.6.1.4.1.4756.20.502.20.1.1107 | ColumnnidMSTI3Port6PriorityRemoteB | read-write | current | NID Series card MSTI Port Configuration: MSTI3 Normal Port6 Configuration - Priority |
| 1.3.6.1.4.1.4756.20.502.20.1.1108 | ColumnnidMSTI3Port7PathCostRemoteB | read-write | current | NID Series card MSTI Port Configuration: MSTI3 Normal Port7 Configuration - Path Cost Valid values are in the range 0 to 200000000. Setting 0 means Auto path c… |
| 1.3.6.1.4.1.4756.20.502.20.1.1109 | ColumnnidMSTI3Port7PriorityRemoteB | read-write | current | NID Series card MSTI Port Configuration: MSTI3 Normal Port7 Configuration - Priority |
| 1.3.6.1.4.1.4756.20.502.20.1.1110 | ColumnnidMSTI3Port8PathCostRemoteB | read-write | current | NID Series card MSTI Port Configuration: MSTI3 Normal Port8 Configuration - Path Cost Valid values are in the range 0 to 200000000. Setting 0 means Auto path c… |
| 1.3.6.1.4.1.4756.20.502.20.1.1111 | ColumnnidMSTI3Port8PriorityRemoteB | read-write | current | NID Series card MSTI Port Configuration: MSTI3 Normal Port8 Configuration - Priority |
| 1.3.6.1.4.1.4756.20.502.20.1.1112 | ColumnnidMSTI4AggregatedPathCostRemoteB | read-write | current | NID Series card MSTI Port Configuration: MSTI4 Aggregated Ports Configuration - Path Cost Valid values are in the range 0 to 200000000. Setting 0 means Auto pa… |
| 1.3.6.1.4.1.4756.20.502.20.1.1113 | ColumnnidMSTI4AggregatedPriorityRemoteB | read-write | current | NID Series card MSTI Port Configuration: MSTI4 Aggregated Ports Configuration - Priority |
| 1.3.6.1.4.1.4756.20.502.20.1.1114 | ColumnnidMSTI4Port1PathCostRemoteB | read-write | current | NID Series card MSTI Port Configuration: MSTI4 Normal Port1 Configuration - Path Cost Valid values are in the range 0 to 200000000. Setting 0 means Auto path c… |
| 1.3.6.1.4.1.4756.20.502.20.1.1115 | ColumnnidMSTI4Port1PriorityRemoteB | read-write | current | NID Series card MSTI Port Configuration: MSTI4 Normal Port1 Configuration - Priority |
| 1.3.6.1.4.1.4756.20.502.20.1.1116 | ColumnnidMSTI4Port2PathCostRemoteB | read-write | current | NID Series card MSTI Port Configuration: MSTI4 Normal Port2 Configuration - Path Cost Valid values are in the range 0 to 200000000. Setting 0 means Auto path c… |
| 1.3.6.1.4.1.4756.20.502.20.1.1117 | ColumnnidMSTI4Port2PriorityRemoteB | read-write | current | NID Series card MSTI Port Configuration: MSTI4 Normal Port2 Configuration - Priority |
| 1.3.6.1.4.1.4756.20.502.20.1.1118 | ColumnnidMSTI4Port3PathCostRemoteB | read-write | current | NID Series card MSTI Port Configuration: MSTI1 Normal Port3 Configuration - Path Cost Valid values are in the range 0 to 200000000. Setting 0 means Auto path c… |
| 1.3.6.1.4.1.4756.20.502.20.1.1119 | ColumnnidMSTI4Port3PriorityRemoteB | read-write | current | NID Series card MSTI Port Configuration: MSTI4 Normal Port3 Configuration - Priority |
| 1.3.6.1.4.1.4756.20.502.20.1.1120 | ColumnnidMSTI4Port4PathCostRemoteB | read-write | current | NID Series card MSTI Port Configuration: MSTI4 Normal Port4 Configuration - Path Cost Valid values are in the range 0 to 200000000. Setting 0 means Auto path c… |
| 1.3.6.1.4.1.4756.20.502.20.1.1121 | ColumnnidMSTI4Port4PriorityRemoteB | read-write | current | NID Series card MSTI Port Configuration: MSTI4 Normal Port4 Configuration - Priority |
| 1.3.6.1.4.1.4756.20.502.20.1.1122 | ColumnnidMSTI4Port5PathCostRemoteB | read-write | current | NID Series card MSTI Port Configuration: MSTI4 Normal Port5 Configuration - Path Cost Valid values are in the range 0 to 200000000. Setting 0 means Auto path c… |
| 1.3.6.1.4.1.4756.20.502.20.1.1123 | ColumnnidMSTI4Port5PriorityRemoteB | read-write | current | NID Series card MSTI Port Configuration: MSTI4 Normal Port5 Configuration - Priority |
| 1.3.6.1.4.1.4756.20.502.20.1.1124 | ColumnnidMSTI4Port6PathCostRemoteB | read-write | current | NID Series card MSTI Port Configuration: MSTI4 Normal Port4 Configuration - Path Cost Valid values are in the range 0 to 200000000. Setting 0 means Auto path c… |
| 1.3.6.1.4.1.4756.20.502.20.1.1125 | ColumnnidMSTI4Port6PriorityRemoteB | read-write | current | NID Series card MSTI Port Configuration: MSTI4 Normal Port6 Configuration - Priority |
| 1.3.6.1.4.1.4756.20.502.20.1.1126 | ColumnnidMSTI4Port7PathCostRemoteB | read-write | current | NID Series card MSTI Port Configuration: MSTI4 Normal Port7 Configuration - Path Cost Valid values are in the range 0 to 200000000. Setting 0 means Auto path c… |
| 1.3.6.1.4.1.4756.20.502.20.1.1127 | ColumnnidMSTI4Port7PriorityRemoteB | read-write | current | NID Series card MSTI Port Configuration: MSTI4 Normal Port7 Configuration - Priority |
| 1.3.6.1.4.1.4756.20.502.20.1.1128 | ColumnnidMSTI4Port8PathCostRemoteB | read-write | current | NID Series card MSTI Port Configuration: MSTI4 Normal Port8 Configuration - Path Cost Valid values are in the range 0 to 200000000. Setting 0 means Auto path c… |
| 1.3.6.1.4.1.4756.20.502.20.1.1129 | ColumnnidMSTI4Port8PriorityRemoteB | read-write | current | NID Series card MSTI Port Configuration: MSTI4 Normal Port8 Configuration - Priority |
| 1.3.6.1.4.1.4756.20.502.20.1.1130 | ColumnnidMSTI5AggregatedPathCostRemoteB | read-write | current | NID Series card MSTI Port Configuration: MSTI5 Aggregated Ports Configuration - Path Cost Valid values are in the range 0 to 200000000. Setting 0 means Auto pa… |
| 1.3.6.1.4.1.4756.20.502.20.1.1131 | ColumnnidMSTI5AggregatedPriorityRemoteB | read-write | current | NID Series card MSTI Port Configuration: MSTI5 Aggregated Ports Configuration - Priority |
| 1.3.6.1.4.1.4756.20.502.20.1.1132 | ColumnnidMSTI5Port1PathCostRemoteB | read-write | current | NID Series card MSTI Port Configuration: MSTI5 Normal Port1 Configuration - Path Cost Valid values are in the range 0 to 200000000. Setting 0 means Auto path c… |
| 1.3.6.1.4.1.4756.20.502.20.1.1133 | ColumnnidMSTI5Port1PriorityRemoteB | read-write | current | NID Series card MSTI Port Configuration: MSTI5 Normal Port1 Configuration - Priority |
| 1.3.6.1.4.1.4756.20.502.20.1.1134 | ColumnnidMSTI5Port2PathCostRemoteB | read-write | current | NID Series card MSTI Port Configuration: MSTI5 Normal Port2 Configuration - Path Cost Valid values are in the range 0 to 200000000. Setting 0 means Auto path c… |
| 1.3.6.1.4.1.4756.20.502.20.1.1135 | ColumnnidMSTI5Port2PriorityRemoteB | read-write | current | NID Series card MSTI Port Configuration: MSTI5 Normal Port2 Configuration - Priority |
| 1.3.6.1.4.1.4756.20.502.20.1.1136 | ColumnnidMSTI5Port3PathCostRemoteB | read-write | current | NID Series card MSTI Port Configuration: MSTI5 Normal Port3 Configuration - Path Cost Valid values are in the range 0 to 200000000. Setting 0 means Auto path c… |
| 1.3.6.1.4.1.4756.20.502.20.1.1137 | ColumnnidMSTI5Port3PriorityRemoteB | read-write | current | NID Series card MSTI Port Configuration: MSTI5 Normal Port3 Configuration - Priority |
| 1.3.6.1.4.1.4756.20.502.20.1.1138 | ColumnnidMSTI5Port4PathCostRemoteB | read-write | current | NID Series card MSTI Port Configuration: MSTI5 Normal Port4 Configuration - Path Cost Valid values are in the range 0 to 200000000. Setting 0 means Auto path c… |
| 1.3.6.1.4.1.4756.20.502.20.1.1139 | ColumnnidMSTI5Port4PriorityRemoteB | read-write | current | NID Series card MSTI Port Configuration: MSTI5 Normal Port4 Configuration - Priority |
| 1.3.6.1.4.1.4756.20.502.20.1.1140 | ColumnnidMSTI5Port5PathCostRemoteB | read-write | current | NID Series card MSTI Port Configuration: MSTI5 Normal Port5 Configuration - Path Cost Valid values are in the range 0 to 200000000. Setting 0 means Auto path c… |
| 1.3.6.1.4.1.4756.20.502.20.1.1141 | ColumnnidMSTI5Port5PriorityRemoteB | read-write | current | NID Series card MSTI Port Configuration: MSTI5 Normal Port5 Configuration - Priority |
| 1.3.6.1.4.1.4756.20.502.20.1.1142 | ColumnnidMSTI5Port6PathCostRemoteB | read-write | current | NID Series card MSTI Port Configuration: MSTI5 Normal Port6 Configuration - Path Cost Valid values are in the range 0 to 200000000. Setting 0 means Auto path c… |
| 1.3.6.1.4.1.4756.20.502.20.1.1143 | ColumnnidMSTI5Port6PriorityRemoteB | read-write | current | NID Series card MSTI Port Configuration: MSTI5 Normal Port6 Configuration - Priority |
| 1.3.6.1.4.1.4756.20.502.20.1.1144 | ColumnnidMSTI5Port7PathCostRemoteB | read-write | current | NID Series card MSTI Port Configuration: MSTI5 Normal Port7 Configuration - Path Cost Valid values are in the range 0 to 200000000. Setting 0 means Auto path c… |
| 1.3.6.1.4.1.4756.20.502.20.1.1145 | ColumnnidMSTI5Port7PriorityRemoteB | read-write | current | NID Series card MSTI Port Configuration: MSTI5 Normal Port7 Configuration - Priority |
| 1.3.6.1.4.1.4756.20.502.20.1.1146 | ColumnnidMSTI5Port8PathCostRemoteB | read-write | current | NID Series card MSTI Port Configuration: MSTI5 Normal Port8 Configuration - Path Cost Valid values are in the range 0 to 200000000. Setting 0 means Auto path c… |
| 1.3.6.1.4.1.4756.20.502.20.1.1147 | ColumnnidMSTI5Port8PriorityRemoteB | read-write | current | NID Series card MSTI Port Configuration: MSTI5 Normal Port8 Configuration - Priority |
| 1.3.6.1.4.1.4756.20.502.20.1.1148 | ColumnnidMSTI6AggregatedPathCostRemoteB | read-write | current | NID Series card MSTI Port Configuration: MSTI6 Aggregated Ports Configuration - Path Cost Valid values are in the range 0 to 200000000. Setting 0 means Auto pa… |
| 1.3.6.1.4.1.4756.20.502.20.1.1149 | ColumnnidMSTI6AggregatedPriorityRemoteB | read-write | current | NID Series card MSTI Port Configuration: MSTI6 Aggregated Ports Configuration - Priority |
| 1.3.6.1.4.1.4756.20.502.20.1.1150 | ColumnnidMSTI6Port1PathCostRemoteB | read-write | current | NID Series card MSTI Port Configuration: MSTI6 Normal Port1 Configuration - Path Cost Valid values are in the range 0 to 200000000. Setting 0 means Auto path c… |
| 1.3.6.1.4.1.4756.20.502.20.1.1151 | ColumnnidMSTI6Port1PriorityRemoteB | read-write | current | NID Series card MSTI Port Configuration: MSTI6 Normal Port1 Configuration - Priority |
| 1.3.6.1.4.1.4756.20.502.20.1.1152 | ColumnnidMSTI6Port2PathCostRemoteB | read-write | current | NID Series card MSTI Port Configuration: MSTI6 Normal Port2 Configuration - Path Cost Valid values are in the range 0 to 200000000. Setting 0 means Auto path c… |
| 1.3.6.1.4.1.4756.20.502.20.1.1153 | ColumnnidMSTI6Port2PriorityRemoteB | read-write | current | NID Series card MSTI Port Configuration: MSTI6 Normal Port2 Configuration - Priority |
| 1.3.6.1.4.1.4756.20.502.20.1.1154 | ColumnnidMSTI6Port3PathCostRemoteB | read-write | current | NID Series card MSTI Port Configuration: MSTI6 Normal Port3 Configuration - Path Cost Valid values are in the range 0 to 200000000. Setting 0 means Auto path c… |
| 1.3.6.1.4.1.4756.20.502.20.1.1155 | ColumnnidMSTI6Port3PriorityRemoteB | read-write | current | NID Series card MSTI Port Configuration: MSTI6 Normal Port3 Configuration - Priority |
| 1.3.6.1.4.1.4756.20.502.20.1.1156 | ColumnnidMSTI6Port4PathCostRemoteB | read-write | current | NID Series card MSTI Port Configuration: MSTI6 Normal Port4 Configuration - Path Cost Valid values are in the range 0 to 200000000. Setting 0 means Auto path c… |
| 1.3.6.1.4.1.4756.20.502.20.1.1157 | ColumnnidMSTI6Port4PriorityRemoteB | read-write | current | NID Series card MSTI Port Configuration: MSTI6 Normal Port4 Configuration - Priority |
| 1.3.6.1.4.1.4756.20.502.20.1.1158 | ColumnnidMSTI6Port5PathCostRemoteB | read-write | current | NID Series card MSTI Port Configuration: MSTI6 Normal Port5 Configuration - Path Cost Valid values are in the range 0 to 200000000. Setting 0 means Auto path c… |
| 1.3.6.1.4.1.4756.20.502.20.1.1159 | ColumnnidMSTI6Port5PriorityRemoteB | read-write | current | NID Series card MSTI Port Configuration: MSTI6 Normal Port6 Configuration - Priority |
| 1.3.6.1.4.1.4756.20.502.20.1.1160 | ColumnnidMSTI6Port6PathCostRemoteB | read-write | current | NID Series card MSTI Port Configuration: MSTI6 Normal Port6 Configuration - Path Cost Valid values are in the range 0 to 200000000. Setting 0 means Auto path c… |
| 1.3.6.1.4.1.4756.20.502.20.1.1161 | ColumnnidMSTI6Port6PriorityRemoteB | read-write | current | NID Series card MSTI Port Configuration: MSTI6 Normal Port6 Configuration - Priority |
| 1.3.6.1.4.1.4756.20.502.20.1.1162 | ColumnnidMSTI6Port7PathCostRemoteB | read-write | current | NID Series card MSTI Port Configuration: MSTI6 Normal Port7 Configuration - Path Cost Valid values are in the range 0 to 200000000. Setting 0 means Auto path c… |
| 1.3.6.1.4.1.4756.20.502.20.1.1163 | ColumnnidMSTI6Port7PriorityRemoteB | read-write | current | NID Series card MSTI Port Configuration: MSTI6 Normal Port6 Configuration - Priority |
| 1.3.6.1.4.1.4756.20.502.20.1.1164 | ColumnnidMSTI6Port8PathCostRemoteB | read-write | current | NID Series card MSTI Port Configuration: MSTI6 Normal Port8 Configuration - Path Cost Valid values are in the range 0 to 200000000. Setting 0 means Auto path c… |
| 1.3.6.1.4.1.4756.20.502.20.1.1165 | ColumnnidMSTI6Port8PriorityRemoteB | read-write | current | NID Series card MSTI Port Configuration: MSTI6 Normal Port8 Configuration - Priority |
| 1.3.6.1.4.1.4756.20.502.20.1.1166 | ColumnnidMSTI7AggregatedPathCostRemoteB | read-write | current | NID Series card MSTI Port Configuration: MSTI7 Aggregated Ports Configuration - Path Cost Valid values are in the range 0 to 200000000. Setting 0 means Auto pa… |
| 1.3.6.1.4.1.4756.20.502.20.1.1167 | ColumnnidMSTI7AggregatedPriorityRemoteB | read-write | current | NID Series card MSTI Port Configuration: MSTI7 Aggregated Ports Configuration - Priority |
| 1.3.6.1.4.1.4756.20.502.20.1.1168 | ColumnnidMSTI7Port1PathCostRemoteB | read-write | current | NID Series card MSTI Port Configuration: MSTI1 Normal Port1 Configuration - Path Cost Valid values are in the range 0 to 200000000. Setting 0 means Auto path c… |
| 1.3.6.1.4.1.4756.20.502.20.1.1169 | ColumnnidMSTI7Port1PriorityRemoteB | read-write | current | NID Series card MSTI Port Configuration: MSTI1 Normal Port1 Configuration - Priority |
| 1.3.6.1.4.1.4756.20.502.20.1.1170 | ColumnnidMSTI7Port2PathCostRemoteB | read-write | current | NID Series card MSTI Port Configuration: MSTI7 Normal Port2 Configuration - Path Cost Valid values are in the range 0 to 200000000. Setting 0 means Auto path c… |
| 1.3.6.1.4.1.4756.20.502.20.1.1171 | ColumnnidMSTI7Port2PriorityRemoteB | read-write | current | NID Series card MSTI Port Configuration: MSTI7 Normal Port2 Configuration - Priority |
| 1.3.6.1.4.1.4756.20.502.20.1.1172 | ColumnnidMSTI7Port3PathCostRemoteB | read-write | current | NID Series card MSTI Port Configuration: MSTI7 Normal Port3 Configuration - Path Cost Valid values are in the range 0 to 200000000. Setting 0 means Auto path c… |
| 1.3.6.1.4.1.4756.20.502.20.1.1173 | ColumnnidMSTI7Port3PriorityRemoteB | read-write | current | NID Series card MSTI Port Configuration: MSTI7 Normal Port3 Configuration - Priority |
| 1.3.6.1.4.1.4756.20.502.20.1.1174 | ColumnnidMSTI7Port4PathCostRemoteB | read-write | current | NID Series card MSTI Port Configuration: MSTI7 Normal Port4 Configuration - Path Cost Valid values are in the range 0 to 200000000. Setting 0 means Auto path c… |
| 1.3.6.1.4.1.4756.20.502.20.1.1175 | ColumnnidMSTI7Port4PriorityRemoteB | read-write | current | NID Series card MSTI Port Configuration: MSTI7 Normal Port4 Configuration - Priority |
| 1.3.6.1.4.1.4756.20.502.20.1.1176 | ColumnnidMSTI7Port5PathCostRemoteB | read-write | current | NID Series card MSTI Port Configuration: MSTI7 Normal Port5 Configuration - Path Cost Valid values are in the range 0 to 200000000. Setting 0 means Auto path c… |
| 1.3.6.1.4.1.4756.20.502.20.1.1177 | ColumnnidMSTI7Port5PriorityRemoteB | read-write | current | NID Series card MSTI Port Configuration: MSTI7 Normal Port5 Configuration - Priority |
| 1.3.6.1.4.1.4756.20.502.20.1.1178 | ColumnnidMSTI7Port6PathCostRemoteB | read-write | current | NID Series card MSTI Port Configuration: MSTI7 Normal Port6 Configuration - Path Cost Valid values are in the range 0 to 200000000. Setting 0 means Auto path c… |
| 1.3.6.1.4.1.4756.20.502.20.1.1179 | ColumnnidMSTI7Port6PriorityRemoteB | read-write | current | NID Series card MSTI Port Configuration: MSTI7 Normal Port6 Configuration - Priority |
| 1.3.6.1.4.1.4756.20.502.20.1.1180 | ColumnnidMSTI7Port7PathCostRemoteB | read-write | current | NID Series card MSTI Port Configuration: MSTI7 Normal Port7 Configuration - Path Cost Valid values are in the range 0 to 200000000. Setting 0 means Auto path c… |
| 1.3.6.1.4.1.4756.20.502.20.1.1181 | ColumnnidMSTI7Port7PriorityRemoteB | read-write | current | NID Series card MSTI Port Configuration: MSTI7 Normal Port7 Configuration - Priority |
| 1.3.6.1.4.1.4756.20.502.20.1.1182 | ColumnnidMSTI7Port8PathCostRemoteB | read-write | current | NID Series card MSTI Port Configuration: MSTI7 Normal Port8 Configuration - Path Cost Valid values are in the range 0 to 200000000. Setting 0 means Auto path c… |
| 1.3.6.1.4.1.4756.20.502.20.1.1183 | ColumnnidMSTI7Port8PriorityRemoteB | read-write | current | NID Series card MSTI Port Configuration: MSTI7 Normal Port8 Configuration - Priority |
| 1.3.6.1.4.1.4756.20.502.20.1.1184 | ColumnnidMSTI8AggregatedPathCostRemoteB | read-write | current | NID Series card MSTI Port Configuration: MSTI8 Aggregated Ports Configuration - Path Cost Valid values are in the range 0 to 200000000. Setting 0 means Auto pa… |
| 1.3.6.1.4.1.4756.20.502.20.1.1185 | ColumnnidMSTI8AggregatedPriorityRemoteB | read-write | current | NID Series card MSTI Port Configuration: MSTI7 Aggregated Ports Configuration - Priority |
| 1.3.6.1.4.1.4756.20.502.20.1.1186 | ColumnnidMSTI8Port1PathCostRemoteB | read-write | current | NID Series card MSTI Port Configuration: MSTI8 Normal Port1 Configuration - Path Cost Valid values are in the range 0 to 200000000. Setting 0 means Auto path c… |
| 1.3.6.1.4.1.4756.20.502.20.1.1187 | ColumnnidMSTI8Port1PriorityRemoteB | read-write | current | NID Series card MSTI Port Configuration: MSTI8 Normal Port1 Configuration - Priority |
| 1.3.6.1.4.1.4756.20.502.20.1.1188 | ColumnnidMSTI8Port2PathCostRemoteB | read-write | current | NID Series card MSTI Port Configuration: MSTI8 Normal Port2 Configuration - Path Cost Valid values are in the range 0 to 200000000. Setting 0 means Auto path c… |
| 1.3.6.1.4.1.4756.20.502.20.1.1189 | ColumnnidMSTI8Port2PriorityRemoteB | read-write | current | NID Series card MSTI Port Configuration: MSTI8 Normal Port2 Configuration - Priority |
| 1.3.6.1.4.1.4756.20.502.20.1.1190 | ColumnnidMSTI8Port3PathCostRemoteB | read-write | current | NID Series card MSTI Port Configuration: MSTI8 Normal Port3 Configuration - Path Cost Valid values are in the range 0 to 200000000. Setting 0 means Auto path c… |
| 1.3.6.1.4.1.4756.20.502.20.1.1191 | ColumnnidMSTI8Port3PriorityRemoteB | read-write | current | NID Series card MSTI Port Configuration: MSTI8 Normal Port3 Configuration - Priority |
| 1.3.6.1.4.1.4756.20.502.20.1.1192 | ColumnnidMSTI8Port4PathCostRemoteB | read-write | current | NID Series card MSTI Port Configuration: MSTI8 Normal Port4 Configuration - Path Cost Valid values are in the range 0 to 200000000. Setting 0 means Auto path c… |
| 1.3.6.1.4.1.4756.20.502.20.1.1193 | ColumnnidMSTI8Port4PriorityRemoteB | read-write | current | NID Series card MSTI Port Configuration: MSTI8 Normal Port4 Configuration - Priority |
| 1.3.6.1.4.1.4756.20.502.20.1.1194 | ColumnnidMSTI8Port5PathCostRemoteB | read-write | current | NID Series card MSTI Port Configuration: MSTI8 Normal Port5 Configuration - Path Cost Valid values are in the range 0 to 200000000. Setting 0 means Auto path c… |
| 1.3.6.1.4.1.4756.20.502.20.1.1195 | ColumnnidMSTI8Port5PriorityRemoteB | read-write | current | NID Series card MSTI Port Configuration: MSTI8 Normal Port5 Configuration - Priority |
| 1.3.6.1.4.1.4756.20.502.20.1.1196 | ColumnnidMSTI8Port6PathCostRemoteB | read-write | current | NID Series card MSTI Port Configuration: MSTI8 Normal Port6 Configuration - Path Cost Valid values are in the range 0 to 200000000. Setting 0 means Auto path c… |
| 1.3.6.1.4.1.4756.20.502.20.1.1197 | ColumnnidMSTI8Port6PriorityRemoteB | read-write | current | NID Series card MSTI Port Configuration: MSTI8 Normal Port6 Configuration - Priority |
| 1.3.6.1.4.1.4756.20.502.20.1.1198 | ColumnnidMSTI8Port7PathCostRemoteB | read-write | current | NID Series card MSTI Port Configuration: MSTI8 Normal Port7 Configuration - Path Cost Valid values are in the range 0 to 200000000. Setting 0 means Auto path c… |
| 1.3.6.1.4.1.4756.20.502.20.1.1199 | ColumnnidMSTI8Port7PriorityRemoteB | read-write | current | NID Series card MSTI Port Configuration: MSTI8 Normal Port7 Configuration - Priority |
| 1.3.6.1.4.1.4756.20.502.20.1.1200 | ColumnnidMSTI8Port8PathCostRemoteB | read-write | current | NID Series card MSTI Port Configuration: MSTI7 Normal Port8 Configuration - Path Cost Valid values are in the range 0 to 200000000. Setting 0 means Auto path c… |
| 1.3.6.1.4.1.4756.20.502.20.1.1201 | ColumnnidMSTI8Port8PriorityRemoteB | read-write | current | NID Series card MSTI Port Configuration: MSTI8 Normal Port8 Configuration - Priority |
| 1.3.6.1.4.1.4756.20.502.20.1.1202 | ColumnnidMSTI9AggregatedPathCostRemoteB | read-write | current | NID Series card MSTI Port Configuration: MSTI9 Aggregated Ports Configuration - Path Cost Valid values are in the range 0 to 200000000. Setting 0 means Auto pa… |
| 1.3.6.1.4.1.4756.20.502.20.1.1203 | ColumnnidMSTI9AggregatedPriorityRemoteB | read-write | current | NID Series card MSTI Port Configuration: MSTI9 Aggregated Ports Configuration - Priority |
| 1.3.6.1.4.1.4756.20.502.20.1.1204 | ColumnnidMSTI9Port1PathCostRemoteB | read-write | current | NID Series card MSTI Port Configuration: MSTI9 Normal Port1 Configuration - Path Cost Valid values are in the range 0 to 200000000. Setting 0 means Auto path c… |
| 1.3.6.1.4.1.4756.20.502.20.1.1205 | ColumnnidMSTI9Port1PriorityRemoteB | read-write | current | NID Series card MSTI Port Configuration: MSTI9 Normal Port1 Configuration - Priority |
| 1.3.6.1.4.1.4756.20.502.20.1.1206 | ColumnnidMSTI9Port2PathCostRemoteB | read-write | current | NID Series card MSTI Port Configuration: MSTI9 Normal Port2 Configuration - Path Cost Valid values are in the range 0 to 200000000. Setting 0 means Auto path c… |
| 1.3.6.1.4.1.4756.20.502.20.1.1207 | ColumnnidMSTI9Port2PriorityRemoteB | read-write | current | NID Series card MSTI Port Configuration: MSTI8 Normal Port2 Configuration - Priority |
| 1.3.6.1.4.1.4756.20.502.20.1.1208 | ColumnnidMSTI9Port3PathCostRemoteB | read-write | current | NID Series card MSTI Port Configuration: MSTI8 Normal Port3 Configuration - Path Cost Valid values are in the range 0 to 200000000. Setting 0 means Auto path c… |
| 1.3.6.1.4.1.4756.20.502.20.1.1209 | ColumnnidMSTI9Port3PriorityRemoteB | read-write | current | NID Series card MSTI Port Configuration: MSTI9 Normal Port3 Configuration - Priority |
| 1.3.6.1.4.1.4756.20.502.20.1.1210 | ColumnnidMSTI9Port4PathCostRemoteB | read-write | current | NID Series card MSTI Port Configuration: MSTI9 Normal Port4 Configuration - Path Cost Valid values are in the range 0 to 200000000. Setting 0 means Auto path c… |
| 1.3.6.1.4.1.4756.20.502.20.1.1211 | ColumnnidMSTI9Port4PriorityRemoteB | read-write | current | NID Series card MSTI Port Configuration: MSTI9 Normal Port4 Configuration - Priority |
| 1.3.6.1.4.1.4756.20.502.20.1.1212 | ColumnnidMSTI9Port5PathCostRemoteB | read-write | current | NID Series card MSTI Port Configuration: MSTI9 Normal Port5 Configuration - Path Cost Valid values are in the range 0 to 200000000. Setting 0 means Auto path c… |
| 1.3.6.1.4.1.4756.20.502.20.1.1213 | ColumnnidMSTI9Port5PriorityRemoteB | read-write | current | NID Series card MSTI Port Configuration: MSTI9 Normal Port5 Configuration - Priority |
| 1.3.6.1.4.1.4756.20.502.20.1.1214 | ColumnnidMSTI9Port6PathCostRemoteB | read-write | current | NID Series card MSTI Port Configuration: MSTI9 Normal Port6 Configuration - Path Cost Valid values are in the range 0 to 200000000. Setting 0 means Auto path c… |
| 1.3.6.1.4.1.4756.20.502.20.1.1215 | ColumnnidMSTI9Port6PriorityRemoteB | read-write | current | NID Series card MSTI Port Configuration: MSTI9 Normal Port6 Configuration - Priority |
| 1.3.6.1.4.1.4756.20.502.20.1.1216 | ColumnnidMSTI9Port7PathCostRemoteB | read-write | current | NID Series card MSTI Port Configuration: MSTI9 Normal Port7 Configuration - Path Cost Valid values are in the range 0 to 200000000. Setting 0 means Auto path c… |
| 1.3.6.1.4.1.4756.20.502.20.1.1217 | ColumnnidMSTI9Port7PriorityRemoteB | read-write | current | NID Series card MSTI Port Configuration: MSTI9 Normal Port7 Configuration - Priority |
| 1.3.6.1.4.1.4756.20.502.20.1.1218 | ColumnnidMSTI9Port8PathCostRemoteB | read-write | current | NID Series card MSTI Port Configuration: MSTI8 Normal Port8 Configuration - Path Cost Valid values are in the range 0 to 200000000. Setting 0 means Auto path c… |
| 1.3.6.1.4.1.4756.20.502.20.1.1219 | ColumnnidMSTI9Port8PriorityRemoteB | read-write | current | NID Series card MSTI Port Configuration: MSTI9 Normal Port8 Configuration - Priority |
| 1.3.6.1.4.1.4756.20.502.20.1.1220 | ColumnnidMSTI10AggregatedPathCostRemoteB | read-write | current | NID Series card MSTI Port Configuration: MSTI10 Aggregated Ports Configuration - Path Cost Valid values are in the range 0 to 200000000. Setting 0 means Auto p… |
| 1.3.6.1.4.1.4756.20.502.20.1.1221 | ColumnnidMSTI10AggregatedPriorityRemoteB | read-write | current | NID Series card MSTI Port Configuration: MSTI10 Aggregated Ports Configuration - Priority |
| 1.3.6.1.4.1.4756.20.502.20.1.1222 | ColumnnidMSTI10Port1PathCostRemoteB | read-write | current | NID Series card MSTI Port Configuration: MSTI10 Normal Port1 Configuration - Path Cost Valid values are in the range 0 to 200000000. Setting 0 means Auto path … |
| 1.3.6.1.4.1.4756.20.502.20.1.1223 | ColumnnidMSTI10Port1PriorityRemoteB | read-write | current | NID Series card MSTI Port Configuration: MSTI10 Normal Port1 Configuration - Priority |
| 1.3.6.1.4.1.4756.20.502.20.1.1224 | ColumnnidMSTI10Port2PathCostRemoteB | read-write | current | NID Series card MSTI Port Configuration: MSTI10 Normal Port2 Configuration - Path Cost Valid values are in the range 0 to 200000000. Setting 0 means Auto path … |
| 1.3.6.1.4.1.4756.20.502.20.1.1225 | ColumnnidMSTI10Port2PriorityRemoteB | read-write | current | NID Series card MSTI Port Configuration: MSTI8 Normal Port2 Configuration - Priority |
| 1.3.6.1.4.1.4756.20.502.20.1.1226 | ColumnnidMSTI10Port3PathCostRemoteB | read-write | current | NID Series card MSTI Port Configuration: MSTI8 Normal Port3 Configuration - Path Cost Valid values are in the range 0 to 200000000. Setting 0 means Auto path c… |
| 1.3.6.1.4.1.4756.20.502.20.1.1227 | ColumnnidMSTI10Port3PriorityRemoteB | read-write | current | NID Series card MSTI Port Configuration: MSTI10 Normal Port3 Configuration - Priority |
| 1.3.6.1.4.1.4756.20.502.20.1.1228 | ColumnnidMSTI10Port4PathCostRemoteB | read-write | current | NID Series card MSTI Port Configuration: MSTI10 Normal Port4 Configuration - Path Cost Valid values are in the range 0 to 200000000. Setting 0 means Auto path … |
| 1.3.6.1.4.1.4756.20.502.20.1.1229 | ColumnnidMSTI10Port4PriorityRemoteB | read-write | current | NID Series card MSTI Port Configuration: MSTI10 Normal Port4 Configuration - Priority |
| 1.3.6.1.4.1.4756.20.502.20.1.1230 | ColumnnidMSTI10Port5PathCostRemoteB | read-write | current | NID Series card MSTI Port Configuration: MSTI10 Normal Port5 Configuration - Path Cost Valid values are in the range 0 to 200000000. Setting 0 means Auto path … |
| 1.3.6.1.4.1.4756.20.502.20.1.1231 | ColumnnidMSTI10Port5PriorityRemoteB | read-write | current | NID Series card MSTI Port Configuration: MSTI10 Normal Port5 Configuration - Priority |
| 1.3.6.1.4.1.4756.20.502.20.1.1232 | ColumnnidMSTI10Port6PathCostRemoteB | read-write | current | NID Series card MSTI Port Configuration: MSTI10 Normal Port6 Configuration - Path Cost Valid values are in the range 0 to 200000000. Setting 0 means Auto path … |
| 1.3.6.1.4.1.4756.20.502.20.1.1233 | ColumnnidMSTI10Port6PriorityRemoteB | read-write | current | NID Series card MSTI Port Configuration: MSTI10 Normal Port6 Configuration - Priority |
| 1.3.6.1.4.1.4756.20.502.20.1.1234 | ColumnnidMSTI10Port7PathCostRemoteB | read-write | current | NID Series card MSTI Port Configuration: MSTI10 Normal Port7 Configuration - Path Cost Valid values are in the range 0 to 200000000. Setting 0 means Auto path … |
| 1.3.6.1.4.1.4756.20.502.20.1.1235 | ColumnnidMSTI10Port7PriorityRemoteB | read-write | current | NID Series card MSTI Port Configuration: MSTI10 Normal Port7 Configuration - Priority |
| 1.3.6.1.4.1.4756.20.502.20.1.1236 | ColumnnidMSTI10Port8PathCostRemoteB | read-write | current | NID Series card MSTI Port Configuration: MSTI8 Normal Port8 Configuration - Path Cost Valid values are in the range 0 to 200000000. Setting 0 means Auto path c… |
| 1.3.6.1.4.1.4756.20.502.20.1.1237 | ColumnnidMSTI10Port8PriorityRemoteB | read-write | current | NID Series card MSTI Port Configuration: MSTI10 Normal Port8 Configuration - Priority |
| 1.3.6.1.4.1.4756.20.502.20.1.1238 | ColumnnidMSTI11AggregatedPathCostRemoteB | read-write | current | NID Series card MSTI Port Configuration: MSTI11 Aggregated Ports Configuration - Path Cost Valid values are in the range 0 to 200000000. Setting 0 means Auto p… |
| 1.3.6.1.4.1.4756.20.502.20.1.1239 | ColumnnidMSTI11AggregatedPriorityRemoteB | read-write | current | NID Series card MSTI Port Configuration: MSTI11 Aggregated Ports Configuration - Priority |
| 1.3.6.1.4.1.4756.20.502.20.1.1240 | ColumnnidMSTI11Port1PathCostRemoteB | read-write | current | NID Series card MSTI Port Configuration: MSTI11 Normal Port1 Configuration - Path Cost Valid values are in the range 0 to 200000000. Setting 0 means Auto path … |
| 1.3.6.1.4.1.4756.20.502.20.1.1241 | ColumnnidMSTI11Port1PriorityRemoteB | read-write | current | NID Series card MSTI Port Configuration: MSTI11 Normal Port1 Configuration - Priority |
| 1.3.6.1.4.1.4756.20.502.20.1.1242 | ColumnnidMSTI11Port2PathCostRemoteB | read-write | current | NID Series card MSTI Port Configuration: MSTI11 Normal Port2 Configuration - Path Cost Valid values are in the range 0 to 200000000. Setting 0 means Auto path … |
| 1.3.6.1.4.1.4756.20.502.20.1.1243 | ColumnnidMSTI11Port2PriorityRemoteB | read-write | current | NID Series card MSTI Port Configuration: MSTI8 Normal Port2 Configuration - Priority |
| 1.3.6.1.4.1.4756.20.502.20.1.1244 | ColumnnidMSTI11Port3PathCostRemoteB | read-write | current | NID Series card MSTI Port Configuration: MSTI8 Normal Port3 Configuration - Path Cost Valid values are in the range 0 to 200000000. Setting 0 means Auto path c… |
| 1.3.6.1.4.1.4756.20.502.20.1.1245 | ColumnnidMSTI11Port3PriorityRemoteB | read-write | current | NID Series card MSTI Port Configuration: MSTI11 Normal Port3 Configuration - Priority |
| 1.3.6.1.4.1.4756.20.502.20.1.1246 | ColumnnidMSTI11Port4PathCostRemoteB | read-write | current | NID Series card MSTI Port Configuration: MSTI11 Normal Port4 Configuration - Path Cost Valid values are in the range 0 to 200000000. Setting 0 means Auto path … |
| 1.3.6.1.4.1.4756.20.502.20.1.1247 | ColumnnidMSTI11Port4PriorityRemoteB | read-write | current | NID Series card MSTI Port Configuration: MSTI11 Normal Port4 Configuration - Priority |
| 1.3.6.1.4.1.4756.20.502.20.1.1248 | ColumnnidMSTI11Port5PathCostRemoteB | read-write | current | NID Series card MSTI Port Configuration: MSTI11 Normal Port5 Configuration - Path Cost Valid values are in the range 0 to 200000000. Setting 0 means Auto path … |
| 1.3.6.1.4.1.4756.20.502.20.1.1249 | ColumnnidMSTI11Port5PriorityRemoteB | read-write | current | NID Series card MSTI Port Configuration: MSTI11 Normal Port5 Configuration - Priority |
| 1.3.6.1.4.1.4756.20.502.20.1.1250 | ColumnnidMSTI11Port6PathCostRemoteB | read-write | current | NID Series card MSTI Port Configuration: MSTI11 Normal Port6 Configuration - Path Cost Valid values are in the range 0 to 200000000. Setting 0 means Auto path … |
| 1.3.6.1.4.1.4756.20.502.20.1.1251 | ColumnnidMSTI11Port6PriorityRemoteB | read-write | current | NID Series card MSTI Port Configuration: MSTI11 Normal Port6 Configuration - Priority |
| 1.3.6.1.4.1.4756.20.502.20.1.1252 | ColumnnidMSTI11Port7PathCostRemoteB | read-write | current | NID Series card MSTI Port Configuration: MSTI11 Normal Port7 Configuration - Path Cost Valid values are in the range 0 to 200000000. Setting 0 means Auto path … |
| 1.3.6.1.4.1.4756.20.502.20.1.1253 | ColumnnidMSTI11Port7PriorityRemoteB | read-write | current | NID Series card MSTI Port Configuration: MSTI11 Normal Port7 Configuration - Priority |
| 1.3.6.1.4.1.4756.20.502.20.1.1254 | ColumnnidMSTI11Port8PathCostRemoteB | read-write | current | NID Series card MSTI Port Configuration: MSTI8 Normal Port8 Configuration - Path Cost Valid values are in the range 0 to 200000000. Setting 0 means Auto path c… |
| 1.3.6.1.4.1.4756.20.502.20.1.1255 | ColumnnidMSTI11Port8PriorityRemoteB | read-write | current | NID Series card MSTI Port Configuration: MSTI11 Normal Port8 Configuration - Priority |
| 1.3.6.1.4.1.4756.20.502.20.1.1256 | ColumnnidMSTI12AggregatedPathCostRemoteB | read-write | current | NID Series card MSTI Port Configuration: MSTI12 Aggregated Ports Configuration - Path Cost Valid values are in the range 0 to 200000000. Setting 0 means Auto p… |
| 1.3.6.1.4.1.4756.20.502.20.1.1257 | ColumnnidMSTI12AggregatedPriorityRemoteB | read-write | current | NID Series card MSTI Port Configuration: MSTI12 Aggregated Ports Configuration - Priority |
| 1.3.6.1.4.1.4756.20.502.20.1.1258 | ColumnnidMSTI12Port1PathCostRemoteB | read-write | current | NID Series card MSTI Port Configuration: MSTI12 Normal Port1 Configuration - Path Cost Valid values are in the range 0 to 200000000. Setting 0 means Auto path … |
| 1.3.6.1.4.1.4756.20.502.20.1.1259 | ColumnnidMSTI12Port1PriorityRemoteB | read-write | current | NID Series card MSTI Port Configuration: MSTI12 Normal Port1 Configuration - Priority |
| 1.3.6.1.4.1.4756.20.502.20.1.1260 | ColumnnidMSTI12Port2PathCostRemoteB | read-write | current | NID Series card MSTI Port Configuration: MSTI12 Normal Port2 Configuration - Path Cost Valid values are in the range 0 to 200000000. Setting 0 means Auto path … |
| 1.3.6.1.4.1.4756.20.502.20.1.1261 | ColumnnidMSTI12Port2PriorityRemoteB | read-write | current | NID Series card MSTI Port Configuration: MSTI8 Normal Port2 Configuration - Priority |
| 1.3.6.1.4.1.4756.20.502.20.1.1262 | ColumnnidMSTI12Port3PathCostRemoteB | read-write | current | NID Series card MSTI Port Configuration: MSTI8 Normal Port3 Configuration - Path Cost Valid values are in the range 0 to 200000000. Setting 0 means Auto path c… |
| 1.3.6.1.4.1.4756.20.502.20.1.1263 | ColumnnidMSTI12Port3PriorityRemoteB | read-write | current | NID Series card MSTI Port Configuration: MSTI12 Normal Port3 Configuration - Priority |
| 1.3.6.1.4.1.4756.20.502.20.1.1264 | ColumnnidMSTI12Port4PathCostRemoteB | read-write | current | NID Series card MSTI Port Configuration: MSTI12 Normal Port4 Configuration - Path Cost Valid values are in the range 0 to 200000000. Setting 0 means Auto path … |
| 1.3.6.1.4.1.4756.20.502.20.1.1265 | ColumnnidMSTI12Port4PriorityRemoteB | read-write | current | NID Series card MSTI Port Configuration: MSTI12 Normal Port4 Configuration - Priority |
| 1.3.6.1.4.1.4756.20.502.20.1.1266 | ColumnnidMSTI12Port5PathCostRemoteB | read-write | current | NID Series card MSTI Port Configuration: MSTI12 Normal Port5 Configuration - Path Cost Valid values are in the range 0 to 200000000. Setting 0 means Auto path … |
| 1.3.6.1.4.1.4756.20.502.20.1.1267 | ColumnnidMSTI12Port5PriorityRemoteB | read-write | current | NID Series card MSTI Port Configuration: MSTI12 Normal Port5 Configuration - Priority |
| 1.3.6.1.4.1.4756.20.502.20.1.1268 | ColumnnidMSTI12Port6PathCostRemoteB | read-write | current | NID Series card MSTI Port Configuration: MSTI12 Normal Port6 Configuration - Path Cost Valid values are in the range 0 to 200000000. Setting 0 means Auto path … |
| 1.3.6.1.4.1.4756.20.502.20.1.1269 | ColumnnidMSTI12Port6PriorityRemoteB | read-write | current | NID Series card MSTI Port Configuration: MSTI12 Normal Port6 Configuration - Priority |
| 1.3.6.1.4.1.4756.20.502.20.1.1270 | ColumnnidMSTI12Port7PathCostRemoteB | read-write | current | NID Series card MSTI Port Configuration: MSTI12 Normal Port7 Configuration - Path Cost Valid values are in the range 0 to 200000000. Setting 0 means Auto path … |
| 1.3.6.1.4.1.4756.20.502.20.1.1271 | ColumnnidMSTI12Port7PriorityRemoteB | read-write | current | NID Series card MSTI Port Configuration: MSTI12 Normal Port7 Configuration - Priority |
| 1.3.6.1.4.1.4756.20.502.20.1.1272 | ColumnnidMSTI12Port8PathCostRemoteB | read-write | current | NID Series card MSTI Port Configuration: MSTI8 Normal Port8 Configuration - Path Cost Valid values are in the range 0 to 200000000. Setting 0 means Auto path c… |
| 1.3.6.1.4.1.4756.20.502.20.1.1273 | ColumnnidMSTI12Port8PriorityRemoteB | read-write | current | NID Series card MSTI Port Configuration: MSTI12 Normal Port8 Configuration - Priority |
| 1.3.6.1.4.1.4756.20.502.20.1.1274 | ColumnnidMSTI13AggregatedPathCostRemoteB | read-write | current | NID Series card MSTI Port Configuration: MSTI13 Aggregated Ports Configuration - Path Cost Valid values are in the range 0 to 200000000. Setting 0 means Auto p… |
| 1.3.6.1.4.1.4756.20.502.20.1.1275 | ColumnnidMSTI13AggregatedPriorityRemoteB | read-write | current | NID Series card MSTI Port Configuration: MSTI13 Aggregated Ports Configuration - Priority |
| 1.3.6.1.4.1.4756.20.502.20.1.1276 | ColumnnidMSTI13Port1PathCostRemoteB | read-write | current | NID Series card MSTI Port Configuration: MSTI13 Normal Port1 Configuration - Path Cost Valid values are in the range 0 to 200000000. Setting 0 means Auto path … |
| 1.3.6.1.4.1.4756.20.502.20.1.1277 | ColumnnidMSTI13Port1PriorityRemoteB | read-write | current | NID Series card MSTI Port Configuration: MSTI13 Normal Port1 Configuration - Priority |
| 1.3.6.1.4.1.4756.20.502.20.1.1278 | ColumnnidMSTI13Port2PathCostRemoteB | read-write | current | NID Series card MSTI Port Configuration: MSTI13 Normal Port2 Configuration - Path Cost Valid values are in the range 0 to 200000000. Setting 0 means Auto path … |
| 1.3.6.1.4.1.4756.20.502.20.1.1279 | ColumnnidMSTI13Port2PriorityRemoteB | read-write | current | NID Series card MSTI Port Configuration: MSTI8 Normal Port2 Configuration - Priority |
| 1.3.6.1.4.1.4756.20.502.20.1.1280 | ColumnnidMSTI13Port3PathCostRemoteB | read-write | current | NID Series card MSTI Port Configuration: MSTI8 Normal Port3 Configuration - Path Cost Valid values are in the range 0 to 200000000. Setting 0 means Auto path c… |
| 1.3.6.1.4.1.4756.20.502.20.1.1281 | ColumnnidMSTI13Port3PriorityRemoteB | read-write | current | NID Series card MSTI Port Configuration: MSTI13 Normal Port3 Configuration - Priority |
| 1.3.6.1.4.1.4756.20.502.20.1.1282 | ColumnnidMSTI13Port4PathCostRemoteB | read-write | current | NID Series card MSTI Port Configuration: MSTI13 Normal Port4 Configuration - Path Cost Valid values are in the range 0 to 200000000. Setting 0 means Auto path … |
| 1.3.6.1.4.1.4756.20.502.20.1.1283 | ColumnnidMSTI13Port4PriorityRemoteB | read-write | current | NID Series card MSTI Port Configuration: MSTI13 Normal Port4 Configuration - Priority |
| 1.3.6.1.4.1.4756.20.502.20.1.1284 | ColumnnidMSTI13Port5PathCostRemoteB | read-write | current | NID Series card MSTI Port Configuration: MSTI13 Normal Port5 Configuration - Path Cost Valid values are in the range 0 to 200000000. Setting 0 means Auto path … |
| 1.3.6.1.4.1.4756.20.502.20.1.1285 | ColumnnidMSTI13Port5PriorityRemoteB | read-write | current | NID Series card MSTI Port Configuration: MSTI13 Normal Port5 Configuration - Priority |
| 1.3.6.1.4.1.4756.20.502.20.1.1286 | ColumnnidMSTI13Port6PathCostRemoteB | read-write | current | NID Series card MSTI Port Configuration: MSTI13 Normal Port6 Configuration - Path Cost Valid values are in the range 0 to 200000000. Setting 0 means Auto path … |
| 1.3.6.1.4.1.4756.20.502.20.1.1287 | ColumnnidMSTI13Port6PriorityRemoteB | read-write | current | NID Series card MSTI Port Configuration: MSTI13 Normal Port6 Configuration - Priority |
| 1.3.6.1.4.1.4756.20.502.20.1.1288 | ColumnnidMSTI13Port7PathCostRemoteB | read-write | current | NID Series card MSTI Port Configuration: MSTI13 Normal Port7 Configuration - Path Cost Valid values are in the range 0 to 200000000. Setting 0 means Auto path … |
| 1.3.6.1.4.1.4756.20.502.20.1.1289 | ColumnnidMSTI13Port7PriorityRemoteB | read-write | current | NID Series card MSTI Port Configuration: MSTI13 Normal Port7 Configuration - Priority |
| 1.3.6.1.4.1.4756.20.502.20.1.1290 | ColumnnidMSTI13Port8PathCostRemoteB | read-write | current | NID Series card MSTI Port Configuration: MSTI8 Normal Port8 Configuration - Path Cost Valid values are in the range 0 to 200000000. Setting 0 means Auto path c… |
| 1.3.6.1.4.1.4756.20.502.20.1.1291 | ColumnnidMSTI13Port8PriorityRemoteB | read-write | current | NID Series card MSTI Port Configuration: MSTI13 Normal Port8 Configuration - Priority |
| 1.3.6.1.4.1.4756.20.502.20.1.1292 | ColumnnidMSTI14AggregatedPathCostRemoteB | read-write | current | NID Series card MSTI Port Configuration: MSTI14 Aggregated Ports Configuration - Path Cost Valid values are in the range 0 to 200000000. Setting 0 means Auto p… |
| 1.3.6.1.4.1.4756.20.502.20.1.1293 | ColumnnidMSTI14AggregatedPriorityRemoteB | read-write | current | NID Series card MSTI Port Configuration: MSTI14 Aggregated Ports Configuration - Priority |
| 1.3.6.1.4.1.4756.20.502.20.1.1294 | ColumnnidMSTI14Port1PathCostRemoteB | read-write | current | NID Series card MSTI Port Configuration: MSTI14 Normal Port1 Configuration - Path Cost Valid values are in the range 0 to 200000000. Setting 0 means Auto path … |
| 1.3.6.1.4.1.4756.20.502.20.1.1295 | ColumnnidMSTI14Port1PriorityRemoteB | read-write | current | NID Series card MSTI Port Configuration: MSTI14 Normal Port1 Configuration - Priority |
| 1.3.6.1.4.1.4756.20.502.20.1.1296 | ColumnnidMSTI14Port2PathCostRemoteB | read-write | current | NID Series card MSTI Port Configuration: MSTI14 Normal Port2 Configuration - Path Cost Valid values are in the range 0 to 200000000. Setting 0 means Auto path … |
| 1.3.6.1.4.1.4756.20.502.20.1.1297 | ColumnnidMSTI14Port2PriorityRemoteB | read-write | current | NID Series card MSTI Port Configuration: MSTI8 Normal Port2 Configuration - Priority |
| 1.3.6.1.4.1.4756.20.502.20.1.1298 | ColumnnidMSTI14Port3PathCostRemoteB | read-write | current | NID Series card MSTI Port Configuration: MSTI8 Normal Port3 Configuration - Path Cost Valid values are in the range 0 to 200000000. Setting 0 means Auto path c… |
| 1.3.6.1.4.1.4756.20.502.20.1.1299 | ColumnnidMSTI14Port3PriorityRemoteB | read-write | current | NID Series card MSTI Port Configuration: MSTI14 Normal Port3 Configuration - Priority |
| 1.3.6.1.4.1.4756.20.502.20.1.1300 | ColumnnidMSTI14Port4PathCostRemoteB | read-write | current | NID Series card MSTI Port Configuration: MSTI14 Normal Port4 Configuration - Path Cost Valid values are in the range 0 to 200000000. Setting 0 means Auto path … |
| 1.3.6.1.4.1.4756.20.502.20.1.1301 | ColumnnidMSTI14Port4PriorityRemoteB | read-write | current | NID Series card MSTI Port Configuration: MSTI14 Normal Port4 Configuration - Priority |
| 1.3.6.1.4.1.4756.20.502.20.1.1302 | ColumnnidMSTI14Port5PathCostRemoteB | read-write | current | NID Series card MSTI Port Configuration: MSTI14 Normal Port5 Configuration - Path Cost Valid values are in the range 0 to 200000000. Setting 0 means Auto path … |
| 1.3.6.1.4.1.4756.20.502.20.1.1303 | ColumnnidMSTI14Port5PriorityRemoteB | read-write | current | NID Series card MSTI Port Configuration: MSTI14 Normal Port5 Configuration - Priority |
| 1.3.6.1.4.1.4756.20.502.20.1.1304 | ColumnnidMSTI14Port6PathCostRemoteB | read-write | current | NID Series card MSTI Port Configuration: MSTI14 Normal Port6 Configuration - Path Cost Valid values are in the range 0 to 200000000. Setting 0 means Auto path … |
| 1.3.6.1.4.1.4756.20.502.20.1.1305 | ColumnnidMSTI14Port6PriorityRemoteB | read-write | current | NID Series card MSTI Port Configuration: MSTI14 Normal Port6 Configuration - Priority |
| 1.3.6.1.4.1.4756.20.502.20.1.1306 | ColumnnidMSTI14Port7PathCostRemoteB | read-write | current | NID Series card MSTI Port Configuration: MSTI14 Normal Port7 Configuration - Path Cost Valid values are in the range 0 to 200000000. Setting 0 means Auto path … |
| 1.3.6.1.4.1.4756.20.502.20.1.1307 | ColumnnidMSTI14Port7PriorityRemoteB | read-write | current | NID Series card MSTI Port Configuration: MSTI14 Normal Port7 Configuration - Priority |
| 1.3.6.1.4.1.4756.20.502.20.1.1308 | ColumnnidMSTI14Port8PathCostRemoteB | read-write | current | NID Series card MSTI Port Configuration: MSTI8 Normal Port8 Configuration - Path Cost Valid values are in the range 0 to 200000000. Setting 0 means Auto path c… |
| 1.3.6.1.4.1.4756.20.502.20.1.1309 | ColumnnidMSTI14Port8PriorityRemoteB | read-write | current | NID Series card MSTI Port Configuration: MSTI14 Normal Port8 Configuration - Priority |
| 1.3.6.1.4.1.4756.20.502.20.1.1310 | ColumnnidMSTI15AggregatedPathCostRemoteB | read-write | current | NID Series card MSTI Port Configuration: MSTI15 Aggregated Ports Configuration - Path Cost Valid values are in the range 0 to 200000000. Setting 0 means Auto p… |
| 1.3.6.1.4.1.4756.20.502.20.1.1311 | ColumnnidMSTI15AggregatedPriorityRemoteB | read-write | current | NID Series card MSTI Port Configuration: MSTI15 Aggregated Ports Configuration - Priority |
| 1.3.6.1.4.1.4756.20.502.20.1.1312 | ColumnnidMSTI15Port1PathCostRemoteB | read-write | current | NID Series card MSTI Port Configuration: MSTI15 Normal Port1 Configuration - Path Cost Valid values are in the range 0 to 200000000. Setting 0 means Auto path … |
| 1.3.6.1.4.1.4756.20.502.20.1.1313 | ColumnnidMSTI15Port1PriorityRemoteB | read-write | current | NID Series card MSTI Port Configuration: MSTI15 Normal Port1 Configuration - Priority |
| 1.3.6.1.4.1.4756.20.502.20.1.1314 | ColumnnidMSTI15Port2PathCostRemoteB | read-write | current | NID Series card MSTI Port Configuration: MSTI15 Normal Port2 Configuration - Path Cost Valid values are in the range 0 to 200000000. Setting 0 means Auto path … |
| 1.3.6.1.4.1.4756.20.502.20.1.1315 | ColumnnidMSTI15Port2PriorityRemoteB | read-write | current | NID Series card MSTI Port Configuration: MSTI8 Normal Port2 Configuration - Priority |
| 1.3.6.1.4.1.4756.20.502.20.1.1316 | ColumnnidMSTI15Port3PathCostRemoteB | read-write | current | NID Series card MSTI Port Configuration: MSTI8 Normal Port3 Configuration - Path Cost Valid values are in the range 0 to 200000000. Setting 0 means Auto path c… |
| 1.3.6.1.4.1.4756.20.502.20.1.1317 | ColumnnidMSTI15Port3PriorityRemoteB | read-write | current | NID Series card MSTI Port Configuration: MSTI15 Normal Port3 Configuration - Priority |
| 1.3.6.1.4.1.4756.20.502.20.1.1318 | ColumnnidMSTI15Port4PathCostRemoteB | read-write | current | NID Series card MSTI Port Configuration: MSTI15 Normal Port4 Configuration - Path Cost Valid values are in the range 0 to 200000000. Setting 0 means Auto path … |
| 1.3.6.1.4.1.4756.20.502.20.1.1319 | ColumnnidMSTI15Port4PriorityRemoteB | read-write | current | NID Series card MSTI Port Configuration: MSTI15 Normal Port4 Configuration - Priority |
| 1.3.6.1.4.1.4756.20.502.20.1.1320 | ColumnnidMSTI15Port5PathCostRemoteB | read-write | current | NID Series card MSTI Port Configuration: MSTI15 Normal Port5 Configuration - Path Cost Valid values are in the range 0 to 200000000. Setting 0 means Auto path … |
| 1.3.6.1.4.1.4756.20.502.20.1.1321 | ColumnnidMSTI15Port5PriorityRemoteB | read-write | current | NID Series card MSTI Port Configuration: MSTI15 Normal Port5 Configuration - Priority |
| 1.3.6.1.4.1.4756.20.502.20.1.1322 | ColumnnidMSTI15Port6PathCostRemoteB | read-write | current | NID Series card MSTI Port Configuration: MSTI15 Normal Port6 Configuration - Path Cost Valid values are in the range 0 to 200000000. Setting 0 means Auto path … |
| 1.3.6.1.4.1.4756.20.502.20.1.1323 | ColumnnidMSTI15Port6PriorityRemoteB | read-write | current | NID Series card MSTI Port Configuration: MSTI15 Normal Port6 Configuration - Priority |
| 1.3.6.1.4.1.4756.20.502.20.1.1324 | ColumnnidMSTI15Port7PathCostRemoteB | read-write | current | NID Series card MSTI Port Configuration: MSTI15 Normal Port7 Configuration - Path Cost Valid values are in the range 0 to 200000000. Setting 0 means Auto path … |
| 1.3.6.1.4.1.4756.20.502.20.1.1325 | ColumnnidMSTI15Port7PriorityRemoteB | read-write | current | NID Series card MSTI Port Configuration: MSTI15 Normal Port7 Configuration - Priority |
| 1.3.6.1.4.1.4756.20.502.20.1.1326 | ColumnnidMSTI15Port8PathCostRemoteB | read-write | current | NID Series card MSTI Port Configuration: MSTI8 Normal Port8 Configuration - Path Cost Valid values are in the range 0 to 200000000. Setting 0 means Auto path c… |
| 1.3.6.1.4.1.4756.20.502.20.1.1327 | ColumnnidMSTI15Port8PriorityRemoteB | read-write | current | NID Series card MSTI Port Configuration: MSTI15 Normal Port8 Configuration - Priority |
| 1.3.6.1.4.1.4756.20.502.20.1.1328 | ColumnnidCISTBridgeIDRemoteB | read-only | current | NID Series card STP Bridges status: CIST - Bridge ID |
| 1.3.6.1.4.1.4756.20.502.20.1.1329 | ColumnnidCISTRootIDRemoteB | read-only | current | NID Series card STP Bridges status: CIST - Root ID |
| 1.3.6.1.4.1.4756.20.502.20.1.1330 | ColumnnidCISTRootPortRemoteB | read-only | current | NID Series card STP Bridges status: CIST - Root Port |
| 1.3.6.1.4.1.4756.20.502.20.1.1331 | ColumnnidCISTRootCostRemoteB | read-only | current | NID Series card STP Bridges status: CIST - Root Cost |
| 1.3.6.1.4.1.4756.20.502.20.1.1332 | ColumnnidCISTTopologyFlagRemoteB | read-only | current | NID Series card STP Bridges status: CIST - Topology Flag |
| 1.3.6.1.4.1.4756.20.502.20.1.1333 | ColumnnidCISTTopologyChangeLastRemoteB | read-only | current | NID Series card STP Bridges status: CIST - Topology Change Last |
| 1.3.6.1.4.1.4756.20.502.20.1.1334 | ColumnnidMSTI1BridgeIDRemoteB | read-only | current | NID Series card STP Bridges status: MSTI1 - Bridge ID |
| 1.3.6.1.4.1.4756.20.502.20.1.1335 | ColumnnidMSTI1RootIDRemoteB | read-only | current | NID Series card STP Bridges status: MSTI1 - Root ID |
| 1.3.6.1.4.1.4756.20.502.20.1.1336 | ColumnnidMSTI1RootPortRemoteB | read-only | current | NID Series card STP Bridges status: MSTI1 - Root ID |
| 1.3.6.1.4.1.4756.20.502.20.1.1337 | ColumnnidMSTI1RootCostRemoteB | read-only | current | NID Series card STP Bridges status: MSTI1 - Root Cost |
| 1.3.6.1.4.1.4756.20.502.20.1.1338 | ColumnnidMSTI1TopologyFlagRemoteB | read-only | current | NID Series card STP Bridges status: MSTI1 - Topology Flag |
| 1.3.6.1.4.1.4756.20.502.20.1.1339 | ColumnnidMSTI1TopologyChangeLastRemoteB | read-only | current | NID Series card STP Bridges status: MSTI1 - Topology Change Last |
| 1.3.6.1.4.1.4756.20.502.20.1.1340 | ColumnnidMSTI2BridgeIDRemoteB | read-only | current | NID Series card STP Bridges status: MSTI2 - Bridge ID |
| 1.3.6.1.4.1.4756.20.502.20.1.1341 | ColumnnidMSTI2RootIDRemoteB | read-only | current | NID Series card STP Bridges status: MSTI2 - Root ID |
| 1.3.6.1.4.1.4756.20.502.20.1.1342 | ColumnnidMSTI2RootPortRemoteB | read-only | current | NID Series card STP Bridges status: MSTI2 - Root ID |
| 1.3.6.1.4.1.4756.20.502.20.1.1343 | ColumnnidMSTI2RootCostRemoteB | read-only | current | NID Series card STP Bridges status: MSTI2 - Root Cost |
| 1.3.6.1.4.1.4756.20.502.20.1.1344 | ColumnnidMSTI2TopologyFlagRemoteB | read-only | current | NID Series card STP Bridges status: MSTI2 - Topology Flag |
| 1.3.6.1.4.1.4756.20.502.20.1.1345 | ColumnnidMSTI2TopologyChangeLastRemoteB | read-only | current | NID Series card STP Bridges status: MSTI2 - Topology Change Last |
| 1.3.6.1.4.1.4756.20.502.20.1.1346 | ColumnnidMSTI3BridgeIDRemoteB | read-only | current | NID Series card STP Bridges status: MSTI3 - Bridge ID |
| 1.3.6.1.4.1.4756.20.502.20.1.1347 | ColumnnidMSTI3RootIDRemoteB | read-only | current | NID Series card STP Bridges status: MSTI3 - Root ID |
| 1.3.6.1.4.1.4756.20.502.20.1.1348 | ColumnnidMSTI3RootPortRemoteB | read-only | current | NID Series card STP Bridges status: MSTI3 - Root ID |
| 1.3.6.1.4.1.4756.20.502.20.1.1349 | ColumnnidMSTI3RootCostRemoteB | read-only | current | NID Series card STP Bridges status: MSTI3 - Root Cost |
| 1.3.6.1.4.1.4756.20.502.20.1.1350 | ColumnnidMSTI3TopologyFlagRemoteB | read-only | current | NID Series card STP Bridges status: MSTI3 - Topology Flag |
| 1.3.6.1.4.1.4756.20.502.20.1.1351 | ColumnnidMSTI3TopologyChangeLastRemoteB | read-only | current | NID Series card STP Bridges status: MSTI3 - Topology Change Last |
| 1.3.6.1.4.1.4756.20.502.20.1.1352 | ColumnnidMSTI4BridgeIDRemoteB | read-only | current | NID Series card STP Bridges status: MSTI4 - Bridge ID |
| 1.3.6.1.4.1.4756.20.502.20.1.1353 | ColumnnidMSTI4RootIDRemoteB | read-only | current | NID Series card STP Bridges status: MSTI4 - Root ID |
| 1.3.6.1.4.1.4756.20.502.20.1.1354 | ColumnnidMSTI4RootPortRemoteB | read-only | current | NID Series card STP Bridges status: MSTI4 - Root ID |
| 1.3.6.1.4.1.4756.20.502.20.1.1355 | ColumnnidMSTI4RootCostRemoteB | read-only | current | NID Series card STP Bridges status: MSTI4 - Root Cost |
| 1.3.6.1.4.1.4756.20.502.20.1.1356 | ColumnnidMSTI4TopologyFlagRemoteB | read-only | current | NID Series card STP Bridges status: MSTI4 - Topology Flag |
| 1.3.6.1.4.1.4756.20.502.20.1.1357 | ColumnnidMSTI4TopologyChangeLastRemoteB | read-only | current | NID Series card STP Bridges status: MSTI4 - Topology Change Last |
| 1.3.6.1.4.1.4756.20.502.20.1.1358 | ColumnnidMSTI5BridgeIDRemoteB | read-only | current | NID Series card STP Bridges status: MSTI5 - Bridge ID |
| 1.3.6.1.4.1.4756.20.502.20.1.1359 | ColumnnidMSTI5RootIDRemoteB | read-only | current | NID Series card STP Bridges status: MSTI5 - Root ID |
| 1.3.6.1.4.1.4756.20.502.20.1.1360 | ColumnnidMSTI5RootPortRemoteB | read-only | current | NID Series card STP Bridges status: MSTI5 - Root ID |
| 1.3.6.1.4.1.4756.20.502.20.1.1361 | ColumnnidMSTI5RootCostRemoteB | read-only | current | NID Series card STP Bridges status: MSTI5 - Root Cost |
| 1.3.6.1.4.1.4756.20.502.20.1.1362 | ColumnnidMSTI5TopologyFlagRemoteB | read-only | current | NID Series card STP Bridges status: MSTI5 - Topology Flag |
| 1.3.6.1.4.1.4756.20.502.20.1.1363 | ColumnnidMSTI5TopologyChangeLastRemoteB | read-only | current | NID Series card STP Bridges status: MSTI5 - Topology Change Last |
| 1.3.6.1.4.1.4756.20.502.20.1.1364 | ColumnnidMSTI6BridgeIDRemoteB | read-only | current | NID Series card STP Bridges status: MSTI6 - Bridge ID |
| 1.3.6.1.4.1.4756.20.502.20.1.1365 | ColumnnidMSTI6RootIDRemoteB | read-only | current | NID Series card STP Bridges status: MSTI6 - Root ID |
| 1.3.6.1.4.1.4756.20.502.20.1.1366 | ColumnnidMSTI6RootPortRemoteB | read-only | current | NID Series card STP Bridges status: MSTI6 - Root ID |
| 1.3.6.1.4.1.4756.20.502.20.1.1367 | ColumnnidMSTI6RootCostRemoteB | read-only | current | NID Series card STP Bridges status: MSTI6 - Root Cost |
| 1.3.6.1.4.1.4756.20.502.20.1.1368 | ColumnnidMSTI6TopologyFlagRemoteB | read-only | current | NID Series card STP Bridges status: MSTI6 - Topology Flag |
| 1.3.6.1.4.1.4756.20.502.20.1.1369 | ColumnnidMSTI6TopologyChangeLastRemoteB | read-only | current | NID Series card STP Bridges status: MSTI6 - Topology Change Last |
| 1.3.6.1.4.1.4756.20.502.20.1.1370 | ColumnnidMSTI7BridgeIDRemoteB | read-only | current | NID Series card STP Bridges status: MSTI7 - Bridge ID |
| 1.3.6.1.4.1.4756.20.502.20.1.1371 | ColumnnidMSTI7RootIDRemoteB | read-only | current | NID Series card STP Bridges status: MSTI7 - Root ID |
| 1.3.6.1.4.1.4756.20.502.20.1.1372 | ColumnnidMSTI7RootPortRemoteB | read-only | current | NID Series card STP Bridges status: MSTI7 - Root ID |
| 1.3.6.1.4.1.4756.20.502.20.1.1373 | ColumnnidMSTI7RootCostRemoteB | read-only | current | NID Series card STP Bridges status: MSTI7 - Root Cost |
| 1.3.6.1.4.1.4756.20.502.20.1.1374 | ColumnnidMSTI7TopologyFlagRemoteB | read-only | current | NID Series card STP Bridges status: MSTI7 - Topology Flag |
| 1.3.6.1.4.1.4756.20.502.20.1.1375 | ColumnnidMSTI7TopologyChangeLastRemoteB | read-only | current | NID Series card STP Bridges status: MSTI7 - Topology Change Last |
| 1.3.6.1.4.1.4756.20.502.20.1.1376 | ColumnnidMSTI8BridgeIDRemoteB | read-only | current | NID Series card STP Bridges status: MSTI8 - Bridge ID |
| 1.3.6.1.4.1.4756.20.502.20.1.1377 | ColumnnidMSTI8RootIDRemoteB | read-only | current | NID Series card STP Bridges status: MSTI8 - Root ID |
| 1.3.6.1.4.1.4756.20.502.20.1.1378 | ColumnnidMSTI8RootPortRemoteB | read-only | current | NID Series card STP Bridges status: MSTI8 - Root ID |
| 1.3.6.1.4.1.4756.20.502.20.1.1379 | ColumnnidMSTI8RootCostRemoteB | read-only | current | NID Series card STP Bridges status: MSTI8 - Root Cost |
| 1.3.6.1.4.1.4756.20.502.20.1.1380 | ColumnnidMSTI8TopologyFlagRemoteB | read-only | current | NID Series card STP Bridges status: MSTI8 - Topology Flag |
| 1.3.6.1.4.1.4756.20.502.20.1.1381 | ColumnnidMSTI8TopologyChangeLastRemoteB | read-only | current | NID Series card STP Bridges status: MSTI8 - Topology Change Last |
| 1.3.6.1.4.1.4756.20.502.20.1.1382 | ColumnnidMSTI9BridgeIDRemoteB | read-only | current | NID Series card STP Bridges status: MSTI9 - Bridge ID |
| 1.3.6.1.4.1.4756.20.502.20.1.1383 | ColumnnidMSTI9RootIDRemoteB | read-only | current | NID Series card STP Bridges status: MSTI9 - Root ID |
| 1.3.6.1.4.1.4756.20.502.20.1.1384 | ColumnnidMSTI9RootPortRemoteB | read-only | current | NID Series card STP Bridges status: MSTI9 - Root ID |
| 1.3.6.1.4.1.4756.20.502.20.1.1385 | ColumnnidMSTI9RootCostRemoteB | read-only | current | NID Series card STP Bridges status: MSTI9 - Root Cost |
| 1.3.6.1.4.1.4756.20.502.20.1.1386 | ColumnnidMSTI9TopologyFlagRemoteB | read-only | current | NID Series card STP Bridges status: MSTI9 - Topology Flag |
| 1.3.6.1.4.1.4756.20.502.20.1.1387 | ColumnnidMSTI9TopologyChangeLastRemoteB | read-only | current | NID Series card STP Bridges status: MSTI9 - Topology Change Last |
| 1.3.6.1.4.1.4756.20.502.20.1.1388 | ColumnnidMSTI10BridgeIDRemoteB | read-only | current | NID Series card STP Bridges status: MSTI10 - Bridge ID |
| 1.3.6.1.4.1.4756.20.502.20.1.1389 | ColumnnidMSTI10RootIDRemoteB | read-only | current | NID Series card STP Bridges status: MSTI10 - Root ID |
| 1.3.6.1.4.1.4756.20.502.20.1.1390 | ColumnnidMSTI10RootPortRemoteB | read-only | current | NID Series card STP Bridges status: MSTI10 - Root ID |
| 1.3.6.1.4.1.4756.20.502.20.1.1391 | ColumnnidMSTI10RootCostRemoteB | read-only | current | NID Series card STP Bridges status: MSTI10 - Root Cost |
| 1.3.6.1.4.1.4756.20.502.20.1.1392 | ColumnnidMSTI10TopologyFlagRemoteB | read-only | current | NID Series card STP Bridges status: MSTI10 - Topology Flag |
| 1.3.6.1.4.1.4756.20.502.20.1.1393 | ColumnnidMSTI10TopologyChangeLastRemoteB | read-only | current | NID Series card STP Bridges status: MSTI10 - Topology Change Last |
| 1.3.6.1.4.1.4756.20.502.20.1.1394 | ColumnnidMSTI11BridgeIDRemoteB | read-only | current | NID Series card STP Bridges status: MSTI11 - Bridge ID |
| 1.3.6.1.4.1.4756.20.502.20.1.1395 | ColumnnidMSTI11RootIDRemoteB | read-only | current | NID Series card STP Bridges status: MSTI11 - Root ID |
| 1.3.6.1.4.1.4756.20.502.20.1.1396 | ColumnnidMSTI11RootPortRemoteB | read-only | current | NID Series card STP Bridges status: MSTI11 - Root ID |
| 1.3.6.1.4.1.4756.20.502.20.1.1397 | ColumnnidMSTI11RootCostRemoteB | read-only | current | NID Series card STP Bridges status: MSTI11 - Root Cost |
| 1.3.6.1.4.1.4756.20.502.20.1.1398 | ColumnnidMSTI11TopologyFlagRemoteB | read-only | current | NID Series card STP Bridges status: MSTI11 - Topology Flag |
| 1.3.6.1.4.1.4756.20.502.20.1.1399 | ColumnnidMSTI11TopologyChangeLastRemoteB | read-only | current | NID Series card STP Bridges status: MSTI11 - Topology Change Last |
| 1.3.6.1.4.1.4756.20.502.20.1.1400 | ColumnnidMSTI12BridgeIDRemoteB | read-only | current | NID Series card STP Bridges status: MSTI12 - Bridge ID |
| 1.3.6.1.4.1.4756.20.502.20.1.1401 | ColumnnidMSTI12RootIDRemoteB | read-only | current | NID Series card STP Bridges status: MSTI12 - Root ID |
| 1.3.6.1.4.1.4756.20.502.20.1.1402 | ColumnnidMSTI12RootPortRemoteB | read-only | current | NID Series card STP Bridges status: MSTI12 - Root ID |
| 1.3.6.1.4.1.4756.20.502.20.1.1403 | ColumnnidMSTI12RootCostRemoteB | read-only | current | NID Series card STP Bridges status: MSTI12 - Root Cost |
| 1.3.6.1.4.1.4756.20.502.20.1.1404 | ColumnnidMSTI12TopologyFlagRemoteB | read-only | current | NID Series card STP Bridges status: MSTI12 - Topology Flag |
| 1.3.6.1.4.1.4756.20.502.20.1.1405 | ColumnnidMSTI12TopologyChangeLastRemoteB | read-only | current | NID Series card STP Bridges status: MSTI12 - Topology Change Last |
| 1.3.6.1.4.1.4756.20.502.20.1.1406 | ColumnnidMSTI13BridgeIDRemoteB | read-only | current | NID Series card STP Bridges status: MSTI13 - Bridge ID |
| 1.3.6.1.4.1.4756.20.502.20.1.1407 | ColumnnidMSTI13RootIDRemoteB | read-only | current | NID Series card STP Bridges status: MSTI13 - Root ID |
| 1.3.6.1.4.1.4756.20.502.20.1.1408 | ColumnnidMSTI13RootPortRemoteB | read-only | current | NID Series card STP Bridges status: MSTI13 - Root ID |
| 1.3.6.1.4.1.4756.20.502.20.1.1409 | ColumnnidMSTI13RootCostRemoteB | read-only | current | NID Series card STP Bridges status: MSTI13 - Root Cost |
| 1.3.6.1.4.1.4756.20.502.20.1.1410 | ColumnnidMSTI13TopologyFlagRemoteB | read-only | current | NID Series card STP Bridges status: MSTI13 - Topology Flag |
| 1.3.6.1.4.1.4756.20.502.20.1.1411 | ColumnnidMSTI13TopologyChangeLastRemoteB | read-only | current | NID Series card STP Bridges status: MSTI13 - Topology Change Last |
| 1.3.6.1.4.1.4756.20.502.20.1.1412 | ColumnnidMSTI14BridgeIDRemoteB | read-only | current | NID Series card STP Bridges status: MSTI14 - Bridge ID |
| 1.3.6.1.4.1.4756.20.502.20.1.1413 | ColumnnidMSTI14RootIDRemoteB | read-only | current | NID Series card STP Bridges status: MSTI14 - Root ID |
| 1.3.6.1.4.1.4756.20.502.20.1.1414 | ColumnnidMSTI14RootPortRemoteB | read-only | current | NID Series card STP Bridges status: MSTI14 - Root ID |
| 1.3.6.1.4.1.4756.20.502.20.1.1415 | ColumnnidMSTI14RootCostRemoteB | read-only | current | NID Series card STP Bridges status: MSTI14 - Root Cost |
| 1.3.6.1.4.1.4756.20.502.20.1.1416 | ColumnnidMSTI14TopologyFlagRemoteB | read-only | current | NID Series card STP Bridges status: MSTI14 - Topology Flag |
| 1.3.6.1.4.1.4756.20.502.20.1.1417 | ColumnnidMSTI14TopologyChangeLastRemoteB | read-only | current | NID Series card STP Bridges status: MSTI14 - Topology Change Last |
| 1.3.6.1.4.1.4756.20.502.20.1.1418 | ColumnnidMSTI15BridgeIDRemoteB | read-only | current | NID Series card STP Bridges status: MSTI15 - Bridge ID |
| 1.3.6.1.4.1.4756.20.502.20.1.1419 | ColumnnidMSTI15RootIDRemoteB | read-only | current | NID Series card STP Bridges status: MSTI15 - Root ID |
| 1.3.6.1.4.1.4756.20.502.20.1.1420 | ColumnnidMSTI15RootPortRemoteB | read-only | current | NID Series card STP Bridges status: MSTI15 - Root ID |
| 1.3.6.1.4.1.4756.20.502.20.1.1421 | ColumnnidMSTI15RootCostRemoteB | read-only | current | NID Series card STP Bridges status: MSTI15 - Root Cost |
| 1.3.6.1.4.1.4756.20.502.20.1.1422 | ColumnnidMSTI15TopologyFlagRemoteB | read-only | current | NID Series card STP Bridges status: MSTI15 - Topology Flag |
| 1.3.6.1.4.1.4756.20.502.20.1.1423 | ColumnnidMSTI15TopologyChangeLastRemoteB | read-only | current | NID Series card STP Bridges status: MSTI15 - Topology Change Last |
| 1.3.6.1.4.1.4756.20.502.20.1.1424 | ColumnnidSTPPortStatusInst1PortRemoteB | read-only | current | NID Series card STP Port status: Instance1 - Port |
| 1.3.6.1.4.1.4756.20.502.20.1.1425 | ColumnnidSTPPortStatusInst1CISTRoleRemoteB | read-only | current | NID Series card STP Port status: Instance1 - CIST Role |
| 1.3.6.1.4.1.4756.20.502.20.1.1426 | ColumnnidSTPPortStatusInst1CISTStateRemoteB | read-only | current | NID Series card STP Port status: Instance1 - CIST State |
| 1.3.6.1.4.1.4756.20.502.20.1.1427 | ColumnnidSTPPortStatusInst1UptimeRemoteB | read-only | current | NID Series card STP Port status: Instance1 -Uptime |
| 1.3.6.1.4.1.4756.20.502.20.1.1428 | ColumnnidSTPPortStatusInst2PortRemoteB | read-only | current | NID Series card STP Port status: Instance2 - Port |
| 1.3.6.1.4.1.4756.20.502.20.1.1429 | ColumnnidSTPPortStatusInst2CISTRoleRemoteB | read-only | current | NID Series card STP Port status: Instance2 - CIST Role |
| 1.3.6.1.4.1.4756.20.502.20.1.1430 | ColumnnidSTPPortStatusInst2CISTStateRemoteB | read-only | current | NID Series card STP Port status: Instance2 - CIST State |
| 1.3.6.1.4.1.4756.20.502.20.1.1431 | ColumnnidSTPPortStatusInst2UptimeRemoteB | read-only | current | NID Series card STP Port status: Instance2 -Uptime |
| 1.3.6.1.4.1.4756.20.502.20.1.1432 | ColumnnidSTPPortStatusInst3PortRemoteB | read-only | current | NID Series card STP Port status: Instance3 - Port |
| 1.3.6.1.4.1.4756.20.502.20.1.1433 | ColumnnidSTPPortStatusInst3CISTRoleRemoteB | read-only | current | NID Series card STP Port status: Instance3 - CIST Role |
| 1.3.6.1.4.1.4756.20.502.20.1.1434 | ColumnnidSTPPortStatusInst3CISTStateRemoteB | read-only | current | NID Series card STP Port status: Instance3 - CIST State |
| 1.3.6.1.4.1.4756.20.502.20.1.1435 | ColumnnidSTPPortStatusInst3UptimeRemoteB | read-only | current | NID Series card STP Port status: Instance3 -Uptime |
| 1.3.6.1.4.1.4756.20.502.20.1.1436 | ColumnnidSTPPortStatusInst4PortRemoteB | read-only | current | NID Series card STP Port status: Instance4 - Port |
| 1.3.6.1.4.1.4756.20.502.20.1.1437 | ColumnnidSTPPortStatusInst4CISTRoleRemoteB | read-only | current | NID Series card STP Port status: Instance4 - CIST Role |
| 1.3.6.1.4.1.4756.20.502.20.1.1438 | ColumnnidSTPPortStatusInst4CISTStateRemoteB | read-only | current | NID Series card STP Port status: Instance4 - CIST State |
| 1.3.6.1.4.1.4756.20.502.20.1.1439 | ColumnnidSTPPortStatusInst4UptimeRemoteB | read-only | current | NID Series card STP Port status: Instance4 -Uptime |
| 1.3.6.1.4.1.4756.20.502.20.1.1440 | ColumnnidSTPPortStatusInst5PortRemoteB | read-only | current | NID Series card STP Port status: Instance5 - Port |
| 1.3.6.1.4.1.4756.20.502.20.1.1441 | ColumnnidSTPPortStatusInst5CISTRoleRemoteB | read-only | current | NID Series card STP Port status: Instance5 - CIST Role |
| 1.3.6.1.4.1.4756.20.502.20.1.1442 | ColumnnidSTPPortStatusInst5CISTStateRemoteB | read-only | current | NID Series card STP Port status: Instance5 - CIST State |
| 1.3.6.1.4.1.4756.20.502.20.1.1443 | ColumnnidSTPPortStatusInst5UptimeRemoteB | read-only | current | NID Series card STP Port status: Instance5 -Uptime |
| 1.3.6.1.4.1.4756.20.502.20.1.1444 | ColumnnidSTPPortStatusInst6PortRemoteB | read-only | current | NID Series card STP Port status: Instance6- Port |
| 1.3.6.1.4.1.4756.20.502.20.1.1445 | ColumnnidSTPPortStatusInst6CISTRoleRemoteB | read-only | current | NID Series card STP Port status: Instance6- CIST Role |
| 1.3.6.1.4.1.4756.20.502.20.1.1446 | ColumnnidSTPPortStatusInst6CISTStateRemoteB | read-only | current | NID Series card STP Port status: Instance6- CIST State |
| 1.3.6.1.4.1.4756.20.502.20.1.1447 | ColumnnidSTPPortStatusInst6UptimeRemoteB | read-only | current | NID Series card STP Port status: Instance6-Uptime |
| 1.3.6.1.4.1.4756.20.502.20.1.1448 | ColumnnidSTPPortStatusInst7PortRemoteB | read-only | current | NID Series card STP Port status: Instance7- Port |
| 1.3.6.1.4.1.4756.20.502.20.1.1449 | ColumnnidSTPPortStatusInst7CISTRoleRemoteB | read-only | current | NID Series card STP Port status: Instance7- CIST Role |
| 1.3.6.1.4.1.4756.20.502.20.1.1450 | ColumnnidSTPPortStatusInst7CISTStateRemoteB | read-only | current | NID Series card STP Port status: Instance7- CIST State |
| 1.3.6.1.4.1.4756.20.502.20.1.1451 | ColumnnidSTPPortStatusInst7UptimeRemoteB | read-only | current | NID Series card STP Port status: Instance7-Uptime |
| 1.3.6.1.4.1.4756.20.502.20.1.1452 | ColumnnidSTPPortStatusInst8PortRemoteB | read-only | current | NID Series card STP Port status: Instance8- Port |
| 1.3.6.1.4.1.4756.20.502.20.1.1453 | ColumnnidSTPPortStatusInst8CISTRoleRemoteB | read-only | current | NID Series card STP Port status: Instance8- CIST Role |
| 1.3.6.1.4.1.4756.20.502.20.1.1454 | ColumnnidSTPPortStatusInst8CISTStateRemoteB | read-only | current | NID Series card STP Port status: Instance8- CIST State |
| 1.3.6.1.4.1.4756.20.502.20.1.1455 | ColumnnidSTPPortStatusInst8UptimeRemoteB | read-only | current | NID Series card STP Port status: Instance8-Uptime |
| 1.3.6.1.4.1.4756.20.502.20.1.1456 | ColumnnidSTPStatisticsPort1TxMSTPRemoteB | read-only | current | NID Series card STP Port Statistics: Port1 -Transmitted MSTP |
| 1.3.6.1.4.1.4756.20.502.20.1.1457 | ColumnnidSTPStatisticsPort1TxRSTPRemoteB | read-only | current | NID Series card STP Port Statistics: Port1 -Transmitted RSTP |
| 1.3.6.1.4.1.4756.20.502.20.1.1458 | ColumnnidSTPStatisticsPort1TxSTPRemoteB | read-only | current | NID Series card STP Port Statistics: Port1 -Transmitted RSTP |
| 1.3.6.1.4.1.4756.20.502.20.1.1459 | ColumnnidSTPStatisticsPort1TxTCNRemoteB | read-only | current | NID Series card STP Port Statistics: Port1 -Transmitted RSTP |
| 1.3.6.1.4.1.4756.20.502.20.1.1460 | ColumnnidSTPStatisticsPort1RxMSTPRemoteB | read-only | current | NID Series card STP Port Statistics: Port1 -Received MSTP |
| 1.3.6.1.4.1.4756.20.502.20.1.1461 | ColumnnidSTPStatisticsPort1RxRSTPRemoteB | read-only | current | NID Series card STP Port Statistics: Port1 -Received RSTP |
| 1.3.6.1.4.1.4756.20.502.20.1.1462 | ColumnnidSTPStatisticsPort1RxSTPRemoteB | read-only | current | NID Series card STP Port Statistics: Port1 -Received RSTP |
| 1.3.6.1.4.1.4756.20.502.20.1.1463 | ColumnnidSTPStatisticsPort1RxTCNRemoteB | read-only | current | NID Series card STP Port Statistics: Port1 -Received RSTP |
| 1.3.6.1.4.1.4756.20.502.20.1.1464 | ColumnnidSTPStatisticsPort1DiscardUnknowRemoteB | read-only | current | NID Series card STP Port Statistics: Port1 -Discarded Unknown |
| 1.3.6.1.4.1.4756.20.502.20.1.1465 | ColumnnidSTPStatisticsPort1DiscardIllegalRemoteB | read-only | current | NID Series card STP Port Statistics: Port1 -Discarded Illegal |
| 1.3.6.1.4.1.4756.20.502.20.1.1466 | ColumnnidSTPStatisticsPort2TxMSTPRemoteB | read-only | current | NID Series card STP Port Statistics: Port2 -Transmitted MSTP |
| 1.3.6.1.4.1.4756.20.502.20.1.1467 | ColumnnidSTPStatisticsPort2TxRSTPRemoteB | read-only | current | NID Series card STP Port Statistics: Port2 -Transmitted RSTP |
| 1.3.6.1.4.1.4756.20.502.20.1.1468 | ColumnnidSTPStatisticsPort2TxSTPRemoteB | read-only | current | NID Series card STP Port Statistics: Port2 -Transmitted RSTP |
| 1.3.6.1.4.1.4756.20.502.20.1.1469 | ColumnnidSTPStatisticsPort2TxTCNRemoteB | read-only | current | NID Series card STP Port Statistics: Port2 -Transmitted RSTP |
| 1.3.6.1.4.1.4756.20.502.20.1.1470 | ColumnnidSTPStatisticsPort2RxMSTPRemoteB | read-only | current | NID Series card STP Port Statistics: Port2 -Received MSTP |
| 1.3.6.1.4.1.4756.20.502.20.1.1471 | ColumnnidSTPStatisticsPort2RxRSTPRemoteB | read-only | current | NID Series card STP Port Statistics: Port1 -Received RSTP |
| 1.3.6.1.4.1.4756.20.502.20.1.1472 | ColumnnidSTPStatisticsPort2RxSTPRemoteB | read-only | current | NID Series card STP Port Statistics: Port2 -Received RSTP |
| 1.3.6.1.4.1.4756.20.502.20.1.1473 | ColumnnidSTPStatisticsPort2RxTCNRemoteB | read-only | current | NID Series card STP Port Statistics: Port2 -Received RSTP |
| 1.3.6.1.4.1.4756.20.502.20.1.1474 | ColumnnidSTPStatisticsPort2DiscardUnknowRemoteB | read-only | current | NID Series card STP Port Statistics: Port2 -Discarded Unknown |
| 1.3.6.1.4.1.4756.20.502.20.1.1475 | ColumnnidSTPStatisticsPort2DiscardIllegalRemoteB | read-only | current | NID Series card STP Port Statistics: Port2 -Discarded Illegal |
| 1.3.6.1.4.1.4756.20.502.20.1.1476 | ColumnnidSTPStatisticsPort3TxMSTPRemoteB | read-only | current | NID Series card STP Port Statistics: Port3 -Transmitted MSTP |
| 1.3.6.1.4.1.4756.20.502.20.1.1477 | ColumnnidSTPStatisticsPort3TxRSTPRemoteB | read-only | current | NID Series card STP Port Statistics: Port3 -Transmitted RSTP |
| 1.3.6.1.4.1.4756.20.502.20.1.1478 | ColumnnidSTPStatisticsPort3TxSTPRemoteB | read-only | current | NID Series card STP Port Statistics: Port3 -Transmitted RSTP |
| 1.3.6.1.4.1.4756.20.502.20.1.1479 | ColumnnidSTPStatisticsPort3TxTCNRemoteB | read-only | current | NID Series card STP Port Statistics: Port3 -Transmitted RSTP |
| 1.3.6.1.4.1.4756.20.502.20.1.1480 | ColumnnidSTPStatisticsPort3RxMSTPRemoteB | read-only | current | NID Series card STP Port Statistics: Port3 -Received MSTP |
| 1.3.6.1.4.1.4756.20.502.20.1.1481 | ColumnnidSTPStatisticsPort3RxRSTPRemoteB | read-only | current | NID Series card STP Port Statistics: Port3 -Received RSTP |
| 1.3.6.1.4.1.4756.20.502.20.1.1482 | ColumnnidSTPStatisticsPort3RxSTPRemoteB | read-only | current | NID Series card STP Port Statistics: Port3 -Received RSTP |
| 1.3.6.1.4.1.4756.20.502.20.1.1483 | ColumnnidSTPStatisticsPort3RxTCNRemoteB | read-only | current | NID Series card STP Port Statistics: Port3 -Received RSTP |
| 1.3.6.1.4.1.4756.20.502.20.1.1484 | ColumnnidSTPStatisticsPort3DiscardUnknowRemoteB | read-only | current | NID Series card STP Port Statistics: Port3 -Discarded Unknown |
| 1.3.6.1.4.1.4756.20.502.20.1.1485 | ColumnnidSTPStatisticsPort3DiscardIllegalRemoteB | read-only | current | NID Series card STP Port Statistics: Port3 -Discarded Illegal |
| 1.3.6.1.4.1.4756.20.502.20.1.1486 | ColumnnidSTPStatisticsPort4TxMSTPRemoteB | read-only | current | NID Series card STP Port Statistics: Port4 -Transmitted MSTP |
| 1.3.6.1.4.1.4756.20.502.20.1.1487 | ColumnnidSTPStatisticsPort4TxRSTPRemoteB | read-only | current | NID Series card STP Port Statistics: Port4 -Transmitted RSTP |
| 1.3.6.1.4.1.4756.20.502.20.1.1488 | ColumnnidSTPStatisticsPort4TxSTPRemoteB | read-only | current | NID Series card STP Port Statistics: Port4 -Transmitted RSTP |
| 1.3.6.1.4.1.4756.20.502.20.1.1489 | ColumnnidSTPStatisticsPort4TxTCNRemoteB | read-only | current | NID Series card STP Port Statistics: Port4 -Transmitted RSTP |
| 1.3.6.1.4.1.4756.20.502.20.1.1490 | ColumnnidSTPStatisticsPort4RxMSTPRemoteB | read-only | current | NID Series card STP Port Statistics: Port4 -Received MSTP |
| 1.3.6.1.4.1.4756.20.502.20.1.1491 | ColumnnidSTPStatisticsPort4RxRSTPRemoteB | read-only | current | NID Series card STP Port Statistics: Port4 -Received RSTP |
| 1.3.6.1.4.1.4756.20.502.20.1.1492 | ColumnnidSTPStatisticsPort4RxSTPRemoteB | read-only | current | NID Series card STP Port Statistics: Port4 -Received RSTP |
| 1.3.6.1.4.1.4756.20.502.20.1.1493 | ColumnnidSTPStatisticsPort4RxTCNRemoteB | read-only | current | NID Series card STP Port Statistics: Port4 -Received RSTP |
| 1.3.6.1.4.1.4756.20.502.20.1.1494 | ColumnnidSTPStatisticsPort4DiscardUnknowRemoteB | read-only | current | NID Series card STP Port Statistics: Port4 -Discarded Unknown |
| 1.3.6.1.4.1.4756.20.502.20.1.1495 | ColumnnidSTPStatisticsPort4DiscardIllegalRemoteB | read-only | current | NID Series card STP Port Statistics: Port4 -Discarded Illegal |
| 1.3.6.1.4.1.4756.20.502.20.1.1496 | ColumnnidSTPStatisticsPort5TxMSTPRemoteB | read-only | current | NID Series card STP Port Statistics: Port5 -Transmitted MSTP |
| 1.3.6.1.4.1.4756.20.502.20.1.1497 | ColumnnidSTPStatisticsPort5TxRSTPRemoteB | read-only | current | NID Series card STP Port Statistics: Port5 -Transmitted RSTP |
| 1.3.6.1.4.1.4756.20.502.20.1.1498 | ColumnnidSTPStatisticsPort5TxSTPRemoteB | read-only | current | NID Series card STP Port Statistics: Port5 -Transmitted RSTP |
| 1.3.6.1.4.1.4756.20.502.20.1.1499 | ColumnnidSTPStatisticsPort5TxTCNRemoteB | read-only | current | NID Series card STP Port Statistics: Port5 -Transmitted RSTP |
| 1.3.6.1.4.1.4756.20.502.20.1.1500 | ColumnnidSTPStatisticsPort5RxMSTPRemoteB | read-only | current | NID Series card STP Port Statistics: Port5 -Received MSTP |
| 1.3.6.1.4.1.4756.20.502.20.1.1501 | ColumnnidSTPStatisticsPort5RxRSTPRemoteB | read-only | current | NID Series card STP Port Statistics: Port5 -Received RSTP |
| 1.3.6.1.4.1.4756.20.502.20.1.1502 | ColumnnidSTPStatisticsPort5RxSTPRemoteB | read-only | current | NID Series card STP Port Statistics: Port5 -Received RSTP |
| 1.3.6.1.4.1.4756.20.502.20.1.1503 | ColumnnidSTPStatisticsPort5RxTCNRemoteB | read-only | current | NID Series card STP Port Statistics: Port5 -Received RSTP |
| 1.3.6.1.4.1.4756.20.502.20.1.1504 | ColumnnidSTPStatisticsPort5DiscardUnknowRemoteB | read-only | current | NID Series card STP Port Statistics: Port5 -Discarded Unknown |
| 1.3.6.1.4.1.4756.20.502.20.1.1505 | ColumnnidSTPStatisticsPort5DiscardIllegalRemoteB | read-only | current | NID Series card STP Port Statistics: Port5 -Discarded Illegal |
| 1.3.6.1.4.1.4756.20.502.20.1.1506 | ColumnnidSTPStatisticsPort6TxMSTPRemoteB | read-only | current | NID Series card STP Port Statistics: Port6 -Transmitted MSTP |
| 1.3.6.1.4.1.4756.20.502.20.1.1507 | ColumnnidSTPStatisticsPort6TxRSTPRemoteB | read-only | current | NID Series card STP Port Statistics: Port6 -Transmitted RSTP |
| 1.3.6.1.4.1.4756.20.502.20.1.1508 | ColumnnidSTPStatisticsPort6TxSTPRemoteB | read-only | current | NID Series card STP Port Statistics: Port6 -Transmitted RSTP |
| 1.3.6.1.4.1.4756.20.502.20.1.1509 | ColumnnidSTPStatisticsPort6TxTCNRemoteB | read-only | current | NID Series card STP Port Statistics: Port6 -Transmitted RSTP |
| 1.3.6.1.4.1.4756.20.502.20.1.1510 | ColumnnidSTPStatisticsPort6RxMSTPRemoteB | read-only | current | NID Series card STP Port Statistics: Port6 -Received MSTP |
| 1.3.6.1.4.1.4756.20.502.20.1.1511 | ColumnnidSTPStatisticsPort6RxRSTPRemoteB | read-only | current | NID Series card STP Port Statistics: Port6 -Received RSTP |
| 1.3.6.1.4.1.4756.20.502.20.1.1512 | ColumnnidSTPStatisticsPort6RxSTPRemoteB | read-only | current | NID Series card STP Port Statistics: Port6 -Received RSTP |
| 1.3.6.1.4.1.4756.20.502.20.1.1513 | ColumnnidSTPStatisticsPort6RxTCNRemoteB | read-only | current | NID Series card STP Port Statistics: Port6 -Received RSTP |
| 1.3.6.1.4.1.4756.20.502.20.1.1514 | ColumnnidSTPStatisticsPort6DiscardUnknowRemoteB | read-only | current | NID Series card STP Port Statistics: Port6 -Discarded Unknown |
| 1.3.6.1.4.1.4756.20.502.20.1.1515 | ColumnnidSTPStatisticsPort6DiscardIllegalRemoteB | read-only | current | NID Series card STP Port Statistics: Port6 -Discarded Illegal |
| 1.3.6.1.4.1.4756.20.502.20.1.1516 | ColumnnidSTPStatisticsPort7TxMSTPRemoteB | read-only | current | NID Series card STP Port Statistics: Port7 -Transmitted MSTP |
| 1.3.6.1.4.1.4756.20.502.20.1.1517 | ColumnnidSTPStatisticsPort7TxRSTPRemoteB | read-only | current | NID Series card STP Port Statistics: Port7 -Transmitted RSTP |
| 1.3.6.1.4.1.4756.20.502.20.1.1518 | ColumnnidSTPStatisticsPort7TxSTPRemoteB | read-only | current | NID Series card STP Port Statistics: Port7 -Transmitted RSTP |
| 1.3.6.1.4.1.4756.20.502.20.1.1519 | ColumnnidSTPStatisticsPort7TxTCNRemoteB | read-only | current | NID Series card STP Port Statistics: Port7 -Transmitted RSTP |
| 1.3.6.1.4.1.4756.20.502.20.1.1520 | ColumnnidSTPStatisticsPort7RxMSTPRemoteB | read-only | current | NID Series card STP Port Statistics: Port7 -Received MSTP |
| 1.3.6.1.4.1.4756.20.502.20.1.1521 | ColumnnidSTPStatisticsPort7RxRSTPRemoteB | read-only | current | NID Series card STP Port Statistics: Port7 -Received RSTP |
| 1.3.6.1.4.1.4756.20.502.20.1.1522 | ColumnnidSTPStatisticsPort7RxSTPRemoteB | read-only | current | NID Series card STP Port Statistics: Port7 -Received RSTP |
| 1.3.6.1.4.1.4756.20.502.20.1.1523 | ColumnnidSTPStatisticsPort7RxTCNRemoteB | read-only | current | NID Series card STP Port Statistics: Port7 -Received RSTP |
| 1.3.6.1.4.1.4756.20.502.20.1.1524 | ColumnnidSTPStatisticsPort7DiscardUnknowRemoteB | read-only | current | NID Series card STP Port Statistics: Port7 -Discarded Unknown |
| 1.3.6.1.4.1.4756.20.502.20.1.1525 | ColumnnidSTPStatisticsPort7DiscardIllegalRemoteB | read-only | current | NID Series card STP Port Statistics: Port7 -Discarded Illegal |
| 1.3.6.1.4.1.4756.20.502.20.1.1526 | ColumnnidSTPStatisticsPort8TxMSTPRemoteB | read-only | current | NID Series card STP Port Statistics: Port8 -Transmitted MSTP |
| 1.3.6.1.4.1.4756.20.502.20.1.1527 | ColumnnidSTPStatisticsPort8TxRSTPRemoteB | read-only | current | NID Series card STP Port Statistics: Port8 -Transmitted RSTP |
| 1.3.6.1.4.1.4756.20.502.20.1.1528 | ColumnnidSTPStatisticsPort8TxSTPRemoteB | read-only | current | NID Series card STP Port Statistics: Port8 -Transmitted RSTP |
| 1.3.6.1.4.1.4756.20.502.20.1.1529 | ColumnnidSTPStatisticsPort8TxTCNRemoteB | read-only | current | NID Series card STP Port Statistics: Port8 -Transmitted RSTP |
| 1.3.6.1.4.1.4756.20.502.20.1.1530 | ColumnnidSTPStatisticsPort8RxMSTPRemoteB | read-only | current | NID Series card STP Port Statistics: Port8 -Received MSTP |
| 1.3.6.1.4.1.4756.20.502.20.1.1531 | ColumnnidSTPStatisticsPort8RxRSTPRemoteB | read-only | current | NID Series card STP Port Statistics: Port8 -Received RSTP |
| 1.3.6.1.4.1.4756.20.502.20.1.1532 | ColumnnidSTPStatisticsPort8RxSTPRemoteB | read-only | current | NID Series card STP Port Statistics: Port8 -Received RSTP |
| 1.3.6.1.4.1.4756.20.502.20.1.1533 | ColumnnidSTPStatisticsPort8RxTCNRemoteB | read-only | current | NID Series card STP Port Statistics: Port8 -Received RSTP |
| 1.3.6.1.4.1.4756.20.502.20.1.1534 | ColumnnidSTPStatisticsPort8DiscardUnknowRemoteB | read-only | current | NID Series card STP Port Statistics: Port8 -Discarded Unknown |
| 1.3.6.1.4.1.4756.20.502.20.1.1535 | ColumnnidSTPStatisticsPort8DiscardIllegalRemoteB | read-only | current | NID Series card STP Port Statistics: Port8 -Discarded Illegal |
| 1.3.6.1.4.1.4756.20.502.20.1.1536 | ColumnnidAllowedAccessVLANsRemoteB | read-write | current | NID Series card Global VLAN Configuration: Allowed Access VLANs By default, only VLAN 1 is enabled. More VLANs may be created by using a list syntax where the … |
| 1.3.6.1.4.1.4756.20.502.20.1.1537 | ColumnnidVlanEthertypeRemoteB | read-write | current | NID Series card Global VLAN Configuration: Ethertype for Custom S-ports The format of 'Ethernet Type' is restricted to 0x600-0xFFFF |
| 1.3.6.1.4.1.4756.20.502.20.1.1538 | ColumnnidPort1VlanModeRemoteB | read-write | current | NID Series card Port VLAN Configuration : Port1 - Mode 0: Access 1: Trunk 2: Hybrid |
| 1.3.6.1.4.1.4756.20.502.20.1.1539 | ColumnnidPort1VlanIDRemoteB | read-write | current | NID Series card Port VLAN Configuration : Port1 - VLAN ID |
| 1.3.6.1.4.1.4756.20.502.20.1.1540 | ColumnnidPort1VlanTypeRemoteB | read-write | current | NID Series card Port VLAN Configuration : Port1 - VLAN Type 0: Unaware 1: C-port 2: S-port 3: S-custom-port |
| 1.3.6.1.4.1.4756.20.502.20.1.1541 | ColumnnidPort1VlanIngressFilteringRemoteB | read-write | current | NID Series card Port VLAN Configuration : Port1 - Ingress Filtering 0: Off 1: On |
| 1.3.6.1.4.1.4756.20.502.20.1.1542 | ColumnnidPort1VlanIngressAcceptanceRemoteB | read-write | current | NID Series card Port VLAN Configuration : Port1 - Ingress Acceptance 0: Tagged and untagged 1: Tagged only 2: Untagged only |
| 1.3.6.1.4.1.4756.20.502.20.1.1543 | ColumnnidPort1VlanEgressTaggingRemoteB | read-write | current | NID Series card Port VLAN Configuration : Port1 - Egress Tagging 0: Untag port vlan 1: Tag all 2: Untag all |
| 1.3.6.1.4.1.4756.20.502.20.1.1544 | ColumnnidPort1AllowedVLANSRemoteB | read-write | current | NID Series card Global VLAN Configuration: Port1 - Allowed VLANs By default, only VLAN 1 is enabled. More VLANs may be created by using a list syntax where the… |
| 1.3.6.1.4.1.4756.20.502.20.1.1545 | ColumnnidPort1ForbiddenVLANSRemoteB | read-write | current | NID Series card Global VLAN Configuration: Port1 - Forbidden VLANs By default, the field is left blank, which means that the port may become a member of all po… |
| 1.3.6.1.4.1.4756.20.502.20.1.1546 | ColumnnidPort2VlanModeRemoteB | read-write | current | NID Series card Port VLAN Configuration : Port2 - Mode 0: Access 1: Trunk 2: Hybrid |
| 1.3.6.1.4.1.4756.20.502.20.1.1547 | ColumnnidPort2VlanIDRemoteB | read-write | current | NID Series card Port VLAN Configuration : Port2 - VLAN ID |
| 1.3.6.1.4.1.4756.20.502.20.1.1548 | ColumnnidPort2VlanTypeRemoteB | read-write | current | NID Series card Port VLAN Configuration : Port2 - VLAN Type 0: Unaware 1: C-port 2: S-port 3: S-custom-port |
| 1.3.6.1.4.1.4756.20.502.20.1.1549 | ColumnnidPort2VlanIngressFilteringRemoteB | read-write | current | NID Series card Port VLAN Configuration : Port2 - Ingress Filtering 0: Off 1: On |
| 1.3.6.1.4.1.4756.20.502.20.1.1550 | ColumnnidPort2VlanIngressAcceptanceRemoteB | read-write | current | NID Series card Port VLAN Configuration : Por2 - Ingress Acceptance 0: Tagged and untagged 1: Tagged only 2: Untagged only |
| 1.3.6.1.4.1.4756.20.502.20.1.1551 | ColumnnidPort2VlanEgressTaggingRemoteB | read-write | current | NID Series card Port VLAN Configuration : Port2 - Egress Tagging 0: Untag port vlan 1: Tag all 2: Untag all |
| 1.3.6.1.4.1.4756.20.502.20.1.1552 | ColumnnidPort2AllowedVLANSRemoteB | read-write | current | NID Series card Global VLAN Configuration: Port2 - Allowed VLANs By default, only VLAN 1 is enabled. More VLANs may be created by using a list syntax where the… |
| 1.3.6.1.4.1.4756.20.502.20.1.1553 | ColumnnidPort2ForbiddenVLANSRemoteB | read-write | current | NID Series card Global VLAN Configuration: Port2 - Forbidden VLANs By default, the field is left blank, which means that the port may become a member of all po… |
| 1.3.6.1.4.1.4756.20.502.20.1.1554 | ColumnnidPort3VlanModeRemoteB | read-write | current | NID Series card Port VLAN Configuration : Port3 - Mode 0: Access 1: Trunk 2: Hybrid |
| 1.3.6.1.4.1.4756.20.502.20.1.1555 | ColumnnidPort3VlanIDRemoteB | read-write | current | NID Series card Port VLAN Configuration : Port3 - VLAN ID |
| 1.3.6.1.4.1.4756.20.502.20.1.1556 | ColumnnidPort3VlanTypeRemoteB | read-write | current | NID Series card Port VLAN Configuration : Port3 - VLAN Type 0: Unaware 1: C-port 2: S-port 3: S-custom-port |
| 1.3.6.1.4.1.4756.20.502.20.1.1557 | ColumnnidPort3VlanIngressFilteringRemoteB | read-write | current | NID Series card Port VLAN Configuration : Port3 - Ingress Filtering 0: Off 1: On |
| 1.3.6.1.4.1.4756.20.502.20.1.1558 | ColumnnidPort3VlanIngressAcceptanceRemoteB | read-write | current | NID Series card Port VLAN Configuration : Port3 - Ingress Acceptance 0: Tagged and untagged 1: Tagged only 2: Untagged only |
| 1.3.6.1.4.1.4756.20.502.20.1.1559 | ColumnnidPort3VlanEgressTaggingRemoteB | read-write | current | NID Series card Port VLAN Configuration : Port3 - Egress Tagging 0: Untag port vlan 1: Tag all 2: Untag all |
| 1.3.6.1.4.1.4756.20.502.20.1.1560 | ColumnnidPort3AllowedVLANSRemoteB | read-write | current | NID Series card Global VLAN Configuration: Port3 - Allowed VLANs By default, only VLAN 1 is enabled. More VLANs may be created by using a list syntax where the… |
| 1.3.6.1.4.1.4756.20.502.20.1.1561 | ColumnnidPort3ForbiddenVLANSRemoteB | read-write | current | NID Series card Global VLAN Configuration: Port3 - Forbidden VLANs By default, the field is left blank, which means that the port may become a member of all po… |
| 1.3.6.1.4.1.4756.20.502.20.1.1562 | ColumnnidPort4VlanModeRemoteB | read-write | current | NID Series card Port VLAN Configuration : Port4 - Mode 0: Access 1: Trunk 2: Hybrid |
| 1.3.6.1.4.1.4756.20.502.20.1.1563 | ColumnnidPort4VlanIDRemoteB | read-write | current | NID Series card Port VLAN Configuration : Port4 - VLAN ID |
| 1.3.6.1.4.1.4756.20.502.20.1.1564 | ColumnnidPort4VlanTypeRemoteB | read-write | current | NID Series card Port VLAN Configuration : Port4 - VLAN Type 0: Unaware 1: C-port 2: S-port 3: S-custom-port |
| 1.3.6.1.4.1.4756.20.502.20.1.1565 | ColumnnidPort4VlanIngressFilteringRemoteB | read-write | current | NID Series card Port VLAN Configuration : Port4 - Ingress Filtering 0: Off 1: On |
| 1.3.6.1.4.1.4756.20.502.20.1.1566 | ColumnnidPort4VlanIngressAcceptanceRemoteB | read-write | current | NID Series card Port VLAN Configuration : Port4 - Ingress Acceptance 0: Tagged and untagged 1: Tagged only 2: Untagged only |
| 1.3.6.1.4.1.4756.20.502.20.1.1567 | ColumnnidPort4VlanEgressTaggingRemoteB | read-write | current | NID Series card Port VLAN Configuration : Port4 - Egress Tagging 0: Untag port vlan 1: Tag all 2: Untag all |
| 1.3.6.1.4.1.4756.20.502.20.1.1568 | ColumnnidPort4AllowedVLANSRemoteB | read-write | current | NID Series card Global VLAN Configuration: Port4 - Allowed VLANs By default, only VLAN 1 is enabled. More VLANs may be created by using a list syntax where the… |
| 1.3.6.1.4.1.4756.20.502.20.1.1569 | ColumnnidPort4ForbiddenVLANSRemoteB | read-write | current | NID Series card Global VLAN Configuration: Port4 - Forbidden VLANs By default, the field is left blank, which means that the port may become a member of all po… |
| 1.3.6.1.4.1.4756.20.502.20.1.1570 | ColumnnidPort5VlanModeRemoteB | read-write | current | NID Series card Port VLAN Configuration : Port5 - Mode 0: Access 1: Trunk 2: Hybrid |
| 1.3.6.1.4.1.4756.20.502.20.1.1571 | ColumnnidPort5VlanIDRemoteB | read-write | current | NID Series card Port VLAN Configuration : Port5 - VLAN ID |
| 1.3.6.1.4.1.4756.20.502.20.1.1572 | ColumnnidPort5VlanTypeRemoteB | read-write | current | NID Series card Port VLAN Configuration : Port5 - VLAN Type 0: Unaware 1: C-port 2: S-port 3: S-custom-port |
| 1.3.6.1.4.1.4756.20.502.20.1.1573 | ColumnnidPort5VlanIngressFilteringRemoteB | read-write | current | NID Series card Port VLAN Configuration : Port5 - Ingress Filtering 0: Off 1: On |
| 1.3.6.1.4.1.4756.20.502.20.1.1574 | ColumnnidPort5VlanIngressAcceptanceRemoteB | read-write | current | NID Series card Port VLAN Configuration : Port5 - Ingress Acceptance 0: Tagged and untagged 1: Tagged only 2: Untagged only |
| 1.3.6.1.4.1.4756.20.502.20.1.1575 | ColumnnidPort5VlanEgressTaggingRemoteB | read-write | current | NID Series card Port VLAN Configuration : Port5 - Egress Tagging 0: Untag port vlan 1: Tag all 2: Untag all |
| 1.3.6.1.4.1.4756.20.502.20.1.1576 | ColumnnidPort5AllowedVLANSRemoteB | read-write | current | NID Series card Global VLAN Configuration: Port5 - Allowed VLANs By default, only VLAN 1 is enabled. More VLANs may be created by using a list syntax where the… |
| 1.3.6.1.4.1.4756.20.502.20.1.1577 | ColumnnidPort5ForbiddenVLANSRemoteB | read-write | current | NID Series card Global VLAN Configuration: Port5 - Forbidden VLANs By default, the field is left blank, which means that the port may become a member of all po… |
| 1.3.6.1.4.1.4756.20.502.20.1.1578 | ColumnnidPort6VlanModeRemoteB | read-write | current | NID Series card Port VLAN Configuration : Port6 - Mode 0: Access 1: Trunk 2: Hybrid |
| 1.3.6.1.4.1.4756.20.502.20.1.1579 | ColumnnidPort6VlanIDRemoteB | read-write | current | NID Series card Port VLAN Configuration : Port6 - VLAN ID |
| 1.3.6.1.4.1.4756.20.502.20.1.1580 | ColumnnidPort6VlanTypeRemoteB | read-write | current | NID Series card Port VLAN Configuration : Port6 - VLAN Type 0: Unaware 1: C-port 2: S-port 3: S-custom-port |
| 1.3.6.1.4.1.4756.20.502.20.1.1581 | ColumnnidPort6VlanIngressFilteringRemoteB | read-write | current | NID Series card Port VLAN Configuration : Port6 - Ingress Filtering 0: Off 1: On |
| 1.3.6.1.4.1.4756.20.502.20.1.1582 | ColumnnidPort6VlanIngressAcceptanceRemoteB | read-write | current | NID Series card Port VLAN Configuration : Port6 - Ingress Acceptance 0: Tagged and untagged 1: Tagged only 2: Untagged only |
| 1.3.6.1.4.1.4756.20.502.20.1.1583 | ColumnnidPort6VlanEgressTaggingRemoteB | read-write | current | NID Series card Port VLAN Configuration : Port6 - Egress Tagging 0: Untag port vlan 1: Tag all 2: Untag all |
| 1.3.6.1.4.1.4756.20.502.20.1.1584 | ColumnnidPort6AllowedVLANSRemoteB | read-write | current | NID Series card Global VLAN Configuration: Port6 - Allowed VLANs By default, only VLAN 1 is enabled. More VLANs may be created by using a list syntax where the… |
| 1.3.6.1.4.1.4756.20.502.20.1.1585 | ColumnnidPort6ForbiddenVLANSRemoteB | read-write | current | NID Series card Global VLAN Configuration: Port6 - Forbidden VLANs By default, the field is left blank, which means that the port may become a member of all po… |
| 1.3.6.1.4.1.4756.20.502.20.1.1586 | ColumnnidPort7VlanModeRemoteB | read-write | current | NID Series card Port VLAN Configuration : Port7 - Mode 0: Access 1: Trunk 2: Hybrid |
| 1.3.6.1.4.1.4756.20.502.20.1.1587 | ColumnnidPort7VlanIDRemoteB | read-write | current | NID Series card Port VLAN Configuration : Port7 - VLAN ID |
| 1.3.6.1.4.1.4756.20.502.20.1.1588 | ColumnnidPort7VlanTypeRemoteB | read-write | current | NID Series card Port VLAN Configuration : Port7 - VLAN Type 0: Unaware 1: C-port 2: S-port 3: S-custom-port |
| 1.3.6.1.4.1.4756.20.502.20.1.1589 | ColumnnidPort7VlanIngressFilteringRemoteB | read-write | current | NID Series card Port VLAN Configuration : Port7 - Ingress Filtering 0: Off 1: On |
| 1.3.6.1.4.1.4756.20.502.20.1.1590 | ColumnnidPort7VlanIngressAcceptanceRemoteB | read-write | current | NID Series card Port VLAN Configuration : Port7 - Ingress Acceptance 0: Tagged and untagged 1: Tagged only 2: Untagged only |
| 1.3.6.1.4.1.4756.20.502.20.1.1591 | ColumnnidPort7VlanEgressTaggingRemoteB | read-write | current | NID Series card Port VLAN Configuration : Port7 - Egress Tagging 0: Untag port vlan 1: Tag all 2: Untag all |
| 1.3.6.1.4.1.4756.20.502.20.1.1592 | ColumnnidPort7AllowedVLANSRemoteB | read-write | current | NID Series card Global VLAN Configuration: Port7 - Allowed VLANs By default, only VLAN 1 is enabled. More VLANs may be created by using a list syntax where the… |
| 1.3.6.1.4.1.4756.20.502.20.1.1593 | ColumnnidPort7ForbiddenVLANSRemoteB | read-write | current | NID Series card Global VLAN Configuration: Port7 - Forbidden VLANs By default, the field is left blank, which means that the port may become a member of all po… |
| 1.3.6.1.4.1.4756.20.502.20.1.1594 | ColumnnidPort8VlanModeRemoteB | read-write | current | NID Series card Port VLAN Configuration : Port8 - Mode 0: Access 1: Trunk 2: Hybrid |
| 1.3.6.1.4.1.4756.20.502.20.1.1595 | ColumnnidPort8VlanIDRemoteB | read-write | current | NID Series card Port VLAN Configuration : Port8 - VLAN ID |
| 1.3.6.1.4.1.4756.20.502.20.1.1596 | ColumnnidPort8VlanTypeRemoteB | read-write | current | NID Series card Port VLAN Configuration : Port8 - VLAN Type 0: Unaware 1: C-port 2: S-port 3: S-custom-port |
| 1.3.6.1.4.1.4756.20.502.20.1.1597 | ColumnnidPort8VlanIngressFilteringRemoteB | read-write | current | NID Series card Port VLAN Configuration : Port8 - Ingress Filtering 0: Off 1: On |
| 1.3.6.1.4.1.4756.20.502.20.1.1598 | ColumnnidPort8VlanIngressAcceptanceRemoteB | read-write | current | NID Series card Port VLAN Configuration : Port8 - Ingress Acceptance 0: Tagged and untagged 1: Tagged only 2: Untagged only |
| 1.3.6.1.4.1.4756.20.502.20.1.1599 | ColumnnidPort8VlanEgressTaggingRemoteB | read-write | current | NID Series card Port VLAN Configuration : Port8 - Egress Tagging 0: Untag port vlan 1: Tag all 2: Untag all |
| 1.3.6.1.4.1.4756.20.502.20.1.1600 | ColumnnidPort8AllowedVLANSRemoteB | read-write | current | NID Series card Global VLAN Configuration: Port8 - Allowed VLANs By default, only VLAN 1 is enabled. More VLANs may be created by using a list syntax where the… |
| 1.3.6.1.4.1.4756.20.502.20.1.1601 | ColumnnidPort8ForbiddenVLANSRemoteB | read-write | current | NID Series card Global VLAN Configuration: Port8 - Forbidden VLANs By default, the field is left blank, which means that the port may become a member of all po… |
| 1.3.6.1.4.1.4756.20.502.20.1.1602 | ColumnnidQOSPort1IngressRemoteB | read-write | current | NID Series card QOS Port1 Ingress Enabled 0: NO 1: YES |
| 1.3.6.1.4.1.4756.20.502.20.1.1603 | ColumnnidQOSPort1IngressRateRemoteB | read-write | current | NID Series card QOS Port1 Ingress Rate |
| 1.3.6.1.4.1.4756.20.502.20.1.1604 | ColumnnidQOSPort1IngressRateUnitRemoteB | read-write | current | NID Series card QOS Port1 Ingress Rate Unit 0: Kbps 1: Mbps 2: fps 3: kfps |
| 1.3.6.1.4.1.4756.20.502.20.1.1605 | ColumnnidQOSPort1IngressFlowControlRemoteB | read-write | current | NID Series card QOS Port1 Ingress Flow Control 0: NO 1: YES |
| 1.3.6.1.4.1.4756.20.502.20.1.1606 | ColumnnidQOSPort2IngressRemoteB | read-write | current | NID Series card QOS Port2 Ingress Enabled 0: NO 1: YES |
| 1.3.6.1.4.1.4756.20.502.20.1.1607 | ColumnnidQOSPort2IngressRateRemoteB | read-write | current | NID Series card QOS Port2 Ingress Rate |
| 1.3.6.1.4.1.4756.20.502.20.1.1608 | ColumnnidQOSPort2IngressRateUnitRemoteB | read-write | current | NID Series card QOS Port2 Ingress Rate Unit 0: Kbps 1: Mbps 2: fps 3: kfps |
| 1.3.6.1.4.1.4756.20.502.20.1.1609 | ColumnnidQOSPort2IngressFlowControlRemoteB | read-write | current | NID Series card QOS Port2 Ingress Flow Control 0: NO 1: YES |
| 1.3.6.1.4.1.4756.20.502.20.1.1610 | ColumnnidQOSPort3IngressRemoteB | read-write | current | NID Series card QOS Port3 Ingress Enabled 0: NO 1: YES |
| 1.3.6.1.4.1.4756.20.502.20.1.1611 | ColumnnidQOSPort3IngressRateRemoteB | read-write | current | NID Series card QOS Port3 Ingress Rate |
| 1.3.6.1.4.1.4756.20.502.20.1.1612 | ColumnnidQOSPort3IngressRateUnitRemoteB | read-write | current | NID Series card QOS Port3 Ingress Rate Unit 0: Kbps 1: Mbps 2: fps 3: kfps |
| 1.3.6.1.4.1.4756.20.502.20.1.1613 | ColumnnidQOSPort3IngressFlowControlRemoteB | read-write | current | NID Series card QOS Port3 Ingress Flow Control 0: NO 1: YES |
| 1.3.6.1.4.1.4756.20.502.20.1.1614 | ColumnnidQOSPort4IngressRemoteB | read-write | current | NID Series card QOS Port4 Ingress Enabled 0: NO 1: YES |
| 1.3.6.1.4.1.4756.20.502.20.1.1615 | ColumnnidQOSPort4IngressRateRemoteB | read-write | current | NID Series card QOS Port4 Ingress Rate |
| 1.3.6.1.4.1.4756.20.502.20.1.1616 | ColumnnidQOSPort4IngressRateUnitRemoteB | read-write | current | NID Series card QOS Port4 Ingress Rate Unit 0: Kbps 1: Mbps 2: fps 3: kfps |
| 1.3.6.1.4.1.4756.20.502.20.1.1617 | ColumnnidQOSPort4IngressFlowControlRemoteB | read-write | current | NID Series card QOS Port4 Ingress Flow Control 0: NO 1: YES |
| 1.3.6.1.4.1.4756.20.502.20.1.1618 | ColumnnidQOSPort5IngressRemoteB | read-write | current | NID Series card QOS Port5 Ingress Enabled 0: NO 1: YES |
| 1.3.6.1.4.1.4756.20.502.20.1.1619 | ColumnnidQOSPort5IngressRateRemoteB | read-write | current | NID Series card QOS Port5 Ingress Rate |
| 1.3.6.1.4.1.4756.20.502.20.1.1620 | ColumnnidQOSPort5IngressRateUnitRemoteB | read-write | current | NID Series card QOS Port5 Ingress Rate Unit 0: Kbps 1: Mbps 2: fps 3: kfps |
| 1.3.6.1.4.1.4756.20.502.20.1.1621 | ColumnnidQOSPort5IngressFlowControlRemoteB | read-write | current | NID Series card QOS Port5 Ingress Flow Control 0: NO 1: YES |
| 1.3.6.1.4.1.4756.20.502.20.1.1622 | ColumnnidQOSPort6IngressRemoteB | read-write | current | NID Series card QOS Port6 Ingress Enabled 0: NO 1: YES |
| 1.3.6.1.4.1.4756.20.502.20.1.1623 | ColumnnidQOSPort6IngressRateRemoteB | read-write | current | NID Series card QOS Port6 Ingress Rate |
| 1.3.6.1.4.1.4756.20.502.20.1.1624 | ColumnnidQOSPort6IngressRateUnitRemoteB | read-write | current | NID Series card QOS Port6 Ingress Rate Unit 0: Kbps 1: Mbps 2: fps 3: kfps |
| 1.3.6.1.4.1.4756.20.502.20.1.1625 | ColumnnidQOSPort6IngressFlowControlRemoteB | read-write | current | NID Series card QOS Port6 Ingress Flow Control 0: NO 1: YES |
| 1.3.6.1.4.1.4756.20.502.20.1.1626 | ColumnnidQOSPort7IngressRemoteB | read-write | current | NID Series card QOS Port7 Ingress Enabled 0: NO 1: YES |
| 1.3.6.1.4.1.4756.20.502.20.1.1627 | ColumnnidQOSPort7IngressRateRemoteB | read-write | current | NID Series card QOS Port7 Ingress Rate |
| 1.3.6.1.4.1.4756.20.502.20.1.1628 | ColumnnidQOSPort7IngressRateUnitRemoteB | read-write | current | NID Series card QOS Port7 Ingress Rate Unit 0: Kbps 1: Mbps 2: fps 3: kfps |
| 1.3.6.1.4.1.4756.20.502.20.1.1629 | ColumnnidQOSPort7IngressFlowControlRemoteB | read-write | current | NID Series card QOS Port7 Ingress Flow Control 0: NO 1: YES |
| 1.3.6.1.4.1.4756.20.502.20.1.1630 | ColumnnidQOSPort8IngressRemoteB | read-write | current | NID Series card QOS Port8 Ingress Enabled 0: NO 1: YES |
| 1.3.6.1.4.1.4756.20.502.20.1.1631 | ColumnnidQOSPort8IngressRateRemoteB | read-write | current | NID Series card QOS Port8 Ingress Rate |
| 1.3.6.1.4.1.4756.20.502.20.1.1632 | ColumnnidQOSPort8IngressRateUnitRemoteB | read-write | current | NID Series card QOS Port8 Ingress Rate Unit 0: Kbps 1: Mbps 2: fps 3: kfps |
| 1.3.6.1.4.1.4756.20.502.20.1.1633 | ColumnnidQOSPort8IngressFlowControlRemoteB | read-write | current | NID Series card QOS Port8 Ingress Flow Control 0: NO 1: YES |
| 1.3.6.1.4.1.4756.20.502.20.1.1634 | ColumnnidQOSPort1EgressRemoteB | read-write | current | NID Series card QOS Port1 Egress Enabled 0: NO 1: YES |
| 1.3.6.1.4.1.4756.20.502.20.1.1635 | ColumnnidQOSPort1EgressRateRemoteB | read-write | current | NID Series card QOS Port1 Egress Rate |
| 1.3.6.1.4.1.4756.20.502.20.1.1636 | ColumnnidQOSPort1EgressRateUnitRemoteB | read-write | current | NID Series card QOS Port1 Egress Rate Unit 0: Kbps 1: Mbps |
| 1.3.6.1.4.1.4756.20.502.20.1.1637 | ColumnnidQOSPort2EgressRemoteB | read-write | current | NID Series card QOS Port2 Egress Enabled 0: NO 1: YES |
| 1.3.6.1.4.1.4756.20.502.20.1.1638 | ColumnnidQOSPort2EgressRateRemoteB | read-write | current | NID Series card QOS Port2 Egress Rate |
| 1.3.6.1.4.1.4756.20.502.20.1.1639 | ColumnnidQOSPort2EgressRateUnitRemoteB | read-write | current | NID Series card QOS Port2 Egress Rate Unit 0: Kbps 1: Mbps |
| 1.3.6.1.4.1.4756.20.502.20.1.1640 | ColumnnidQOSPort3EgressRemoteB | read-write | current | NID Series card QOS Port3 Egress Enabled 0: NO 1: YES |
| 1.3.6.1.4.1.4756.20.502.20.1.1641 | ColumnnidQOSPort3EgressRateRemoteB | read-write | current | NID Series card QOS Port3 Egress Rate |
| 1.3.6.1.4.1.4756.20.502.20.1.1642 | ColumnnidQOSPort3EgressRateUnitRemoteB | read-write | current | NID Series card QOS Port3 Egress Rate Unit 0: Kbps 1: Mbps |
| 1.3.6.1.4.1.4756.20.502.20.1.1643 | ColumnnidQOSPort4EgressRemoteB | read-write | current | NID Series card QOS Port4 Egress Enabled 0: NO 1: YES |
| 1.3.6.1.4.1.4756.20.502.20.1.1644 | ColumnnidQOSPort4EgressRateRemoteB | read-write | current | NID Series card QOS Port4 Egress Rate |
| 1.3.6.1.4.1.4756.20.502.20.1.1645 | ColumnnidQOSPort4EgressRateUnitRemoteB | read-write | current | NID Series card QOS Port4 Egress Rate Unit 0: Kbps 1: Mbps |
| 1.3.6.1.4.1.4756.20.502.20.1.1646 | ColumnnidQOSPort5EgressRemoteB | read-write | current | NID Series card QOS Port5 Egress Enabled 0: NO 1: YES |
| 1.3.6.1.4.1.4756.20.502.20.1.1647 | ColumnnidQOSPort5EgressRateRemoteB | read-write | current | NID Series card QOS Port5 Egress Rate |
| 1.3.6.1.4.1.4756.20.502.20.1.1648 | ColumnnidQOSPort5EgressRateUnitRemoteB | read-write | current | NID Series card QOS Port5 Egress Rate Unit 0: Kbps 1: Mbps |
| 1.3.6.1.4.1.4756.20.502.20.1.1649 | ColumnnidQOSPort6EgressRemoteB | read-write | current | NID Series card QOS Port6 Egress Enabled 0: NO 1: YES |
| 1.3.6.1.4.1.4756.20.502.20.1.1650 | ColumnnidQOSPort6EgressRateRemoteB | read-write | current | NID Series card QOS Port6 Egress Rate |
| 1.3.6.1.4.1.4756.20.502.20.1.1651 | ColumnnidQOSPort6EgressRateUnitRemoteB | read-write | current | NID Series card QOS Port6 Egress Rate Unit 0: Kbps 1: Mbps |
| 1.3.6.1.4.1.4756.20.502.20.1.1652 | ColumnnidQOSPort7EgressRemoteB | read-write | current | NID Series card QOS Port7 Egress Enabled 0: NO 1: YES |
| 1.3.6.1.4.1.4756.20.502.20.1.1653 | ColumnnidQOSPort7EgressRateRemoteB | read-write | current | NID Series card QOS Port7 Egress Rate |
| 1.3.6.1.4.1.4756.20.502.20.1.1654 | ColumnnidQOSPort7EgressRateUnitRemoteB | read-write | current | NID Series card QOS Port7 Egress Rate Unit 0: Kbps 1: Mbps |
| 1.3.6.1.4.1.4756.20.502.20.1.1655 | ColumnnidQOSPort8EgressRemoteB | read-write | current | NID Series card QOS Port8 Egress Enabled 0: NO 1: YES |
| 1.3.6.1.4.1.4756.20.502.20.1.1656 | ColumnnidQOSPort8EgressRateRemoteB | read-write | current | NID Series card QOS Port8 Egress Rate |
| 1.3.6.1.4.1.4756.20.502.20.1.1657 | ColumnnidQOSPort8EgressRateUnitRemoteB | read-write | current | NID Series card QOS Port8 Egress Rate Unit 0: Kbps 1: Mbps |
| 1.3.6.1.4.1.4756.20.502.20.1.1658 | ColumnnidQOSUnicastRemoteB | read-write | current | NID Series card QOS Storm Control Configuration- Unicast 0: NO 1: YES |
| 1.3.6.1.4.1.4756.20.502.20.1.1659 | ColumnnidQOSUnicastRateRemoteB | read-write | current | NID Series card QOS Storm Control Configuration- Unicast Rate The rate unit is packets per second (pps). 0: 1 1: 2 2: 4 3: 8 4: 16 5: 32 6: 64 7: 128 8: 256 9:… |
| 1.3.6.1.4.1.4756.20.502.20.1.1660 | ColumnnidQOSMulticastRemoteB | read-write | current | NID Series card QOS Storm Control Configuration- Multicast 0: NO 1: YES |
| 1.3.6.1.4.1.4756.20.502.20.1.1661 | ColumnnidQOSMulticastRateRemoteB | read-write | current | NID Series card QOS Storm Control Configuration- Multicast The rate unit is packets per second (pps). 0: 1 1: 2 2: 4 3: 8 4: 16 5: 32 6: 64 7: 128 8: 256 9: 51… |
| 1.3.6.1.4.1.4756.20.502.20.1.1662 | ColumnnidQOSBroadcastRemoteB | read-write | current | NID Series card QOS Storm Control Configuration- Broadcast 0: NO 1: YES |
| 1.3.6.1.4.1.4756.20.502.20.1.1663 | ColumnnidQOSBroadcastRateRemoteB | read-write | current | NID Series card QOS Storm Control Configuration- Broadcast The rate unit is packets per second (pps). 0: 1 1: 2 2: 4 3: 8 4: 16 5: 32 6: 64 7: 128 8: 256 9: 51… |
| 1.3.6.1.4.1.4756.20.502.20.1.1664 | ColumnnidL2CPPort1DMAC0180C2000000RemoteB | read-write | current | NID Series card Port 1 L2CP Mode 0180C2000000 0: Forward 1: Discard 2: Peer |
| 1.3.6.1.4.1.4756.20.502.20.1.1665 | ColumnnidL2CPPort1DMAC0180C2000001RemoteB | read-write | current | NID Series card Port 1 L2CP Mode 0180C2000001 0: Forward 1: Discard 2: Peer |
| 1.3.6.1.4.1.4756.20.502.20.1.1666 | ColumnnidL2CPPort1DMAC0180C2000002RemoteB | read-write | current | NID Series card Port 1 L2CP Mode 0180C2000002 0: Forward 1: Discard 2: Peer |
| 1.3.6.1.4.1.4756.20.502.20.1.1667 | ColumnnidL2CPPort1DMAC0180C2000003RemoteB | read-write | current | NID Series card Port 1 L2CP Mode 0180C2000003 0: Forward 1: Discard 2: Peer |
| 1.3.6.1.4.1.4756.20.502.20.1.1668 | ColumnnidL2CPPort1DMAC0180C2000004RemoteB | read-write | current | NID Series card Port 1 L2CP Mode 0180C2000004 0: Forward 1: Discard 2: Peer |
| 1.3.6.1.4.1.4756.20.502.20.1.1669 | ColumnnidL2CPPort1DMAC0180C2000005RemoteB | read-write | current | NID Series card Port 1 L2CP Mode 0180C2000005 0: Forward 1: Discard 2: Peer |
| 1.3.6.1.4.1.4756.20.502.20.1.1670 | ColumnnidL2CPPort1DMAC0180C2000006RemoteB | read-write | current | NID Series card Port 1 L2CP Mode 0180C2000006 0: Forward 1: Discard 2: Peer |
| 1.3.6.1.4.1.4756.20.502.20.1.1671 | ColumnnidL2CPPort1DMAC0180C2000007RemoteB | read-write | current | NID Series card Port 1 L2CP Mode 0180C2000007 0: Forward 1: Discard 2: Peer |
| 1.3.6.1.4.1.4756.20.502.20.1.1672 | ColumnnidL2CPPort1DMAC0180C2000008RemoteB | read-write | current | NID Series card Port 1 L2CP Mode 0180C2000008 0: Forward 1: Discard 2: Peer |
| 1.3.6.1.4.1.4756.20.502.20.1.1673 | ColumnnidL2CPPort1DMAC0180C2000009RemoteB | read-write | current | NID Series card Port 1 L2CP Mode 0180C2000009 0: Forward 1: Discard 2: Peer |
| 1.3.6.1.4.1.4756.20.502.20.1.1674 | ColumnnidL2CPPort1DMAC0180C200000ARemoteB | read-write | current | NID Series card Port 1 L2CP Mode 0180C200000A 0: Forward 1: Discard 2: Peer |
| 1.3.6.1.4.1.4756.20.502.20.1.1675 | ColumnnidL2CPPort1DMAC0180C200000BRemoteB | read-write | current | NID Series card Port 1 L2CP Mode 0180C200000B 0: Forward 1: Discard 2: Peer |
| 1.3.6.1.4.1.4756.20.502.20.1.1676 | ColumnnidL2CPPort1DMAC0180C200000CRemoteB | read-write | current | NID Series card Port 1 L2CP Mode 0180C200000C 0: Forward 1: Discard 2: Peer |
| 1.3.6.1.4.1.4756.20.502.20.1.1677 | ColumnnidL2CPPort1DMAC0180C200000DRemoteB | read-write | current | NID Series card Port 1 L2CP Mode 0180C200000D 0: Forward 1: Discard 2: Peer |
| 1.3.6.1.4.1.4756.20.502.20.1.1678 | ColumnnidL2CPPort1DMAC0180C200000ERemoteB | read-write | current | NID Series card Port 1 L2CP Mode 0180C200000E 0: Forward 1: Discard 2: Peer |
| 1.3.6.1.4.1.4756.20.502.20.1.1679 | ColumnnidL2CPPort1DMAC0180C200000FRemoteB | read-write | current | NID Series card Port 1 L2CP Mode 0180C200000F 0: Forward 1: Discard 2: Peer |
| 1.3.6.1.4.1.4756.20.502.20.1.1680 | ColumnnidL2CPPort1DMAC0180C2000010RemoteB | read-write | current | NID Series card Port 1 L2CP Mode 0180C2000010 0: Forward 1: Discard 2: Peer |
| 1.3.6.1.4.1.4756.20.502.20.1.1681 | ColumnnidL2CPPort1DMAC0180C2000020RemoteB | read-write | current | NID Series card Port 1 L2CP Mode 0180C2000020 0: Forward 1: Discard 2: Peer |
| 1.3.6.1.4.1.4756.20.502.20.1.1682 | ColumnnidL2CPPort1DMAC0180C2000021RemoteB | read-write | current | NID Series card Port 1 L2CP Mode 0180C2000021 0: Forward 1: Discard 2: Peer |
| 1.3.6.1.4.1.4756.20.502.20.1.1683 | ColumnnidL2CPPort1DMAC0180C2000022RemoteB | read-write | current | NID Series card Port 1 L2CP Mode 0180C2000022 0: Forward 1: Discard 2: Peer |
| 1.3.6.1.4.1.4756.20.502.20.1.1684 | ColumnnidL2CPPort1DMAC0180C2000023RemoteB | read-write | current | NID Series card Port 1 L2CP Mode 0180C2000023 0: Forward 1: Discard 2: Peer |
| 1.3.6.1.4.1.4756.20.502.20.1.1685 | ColumnnidL2CPPort1DMAC0180C2000024RemoteB | read-write | current | NID Series card Port 1 L2CP Mode 0180C2000024 0: Forward 1: Discard 2: Peer |
| 1.3.6.1.4.1.4756.20.502.20.1.1686 | ColumnnidL2CPPort1DMAC0180C2000025RemoteB | read-write | current | NID Series card Port 1 L2CP Mode 0180C2000025 0: Forward 1: Discard 2: Peer |
| 1.3.6.1.4.1.4756.20.502.20.1.1687 | ColumnnidL2CPPort1DMAC0180C2000026RemoteB | read-write | current | NID Series card Port 1 L2CP Mode 0180C2000026 0: Forward 1: Discard 2: Peer |
| 1.3.6.1.4.1.4756.20.502.20.1.1688 | ColumnnidL2CPPort1DMAC0180C2000027RemoteB | read-write | current | NID Series card Port 1 L2CP Mode 0180C2000027 0: Forward 1: Discard 2: Peer |
| 1.3.6.1.4.1.4756.20.502.20.1.1689 | ColumnnidL2CPPort1DMAC0180C2000028RemoteB | read-write | current | NID Series card Port 1 L2CP Mode 0180C2000028 0: Forward 1: Discard 2: Peer |
| 1.3.6.1.4.1.4756.20.502.20.1.1690 | ColumnnidL2CPPort1DMAC0180C2000029RemoteB | read-write | current | NID Series card Port 1 L2CP Mode 0180C2000029 0: Forward 1: Discard 2: Peer |
| 1.3.6.1.4.1.4756.20.502.20.1.1691 | ColumnnidL2CPPort1DMAC0180C200002ARemoteB | read-write | current | NID Series card Port 1 L2CP Mode 0180C200002A 0: Forward 1: Discard 2: Peer |
| 1.3.6.1.4.1.4756.20.502.20.1.1692 | ColumnnidL2CPPort1DMAC0180C200002BRemoteB | read-write | current | NID Series card Port 1 L2CP Mode 0180C200002B 0: Forward 1: Discard 2: Peer |
| 1.3.6.1.4.1.4756.20.502.20.1.1693 | ColumnnidL2CPPort1DMAC0180C200002CRemoteB | read-write | current | NID Series card Port 1 L2CP Mode 0180C200002C 0: Forward 1: Discard 2: Peer |
| 1.3.6.1.4.1.4756.20.502.20.1.1694 | ColumnnidL2CPPort1DMAC0180C200002DRemoteB | read-write | current | NID Series card Port 1 L2CP Mode 0180C200002D 0: Forward 1: Discard 2: Peer |
| 1.3.6.1.4.1.4756.20.502.20.1.1695 | ColumnnidL2CPPort1DMAC0180C200002ERemoteB | read-write | current | NID Series card Port 1 L2CP Mode 0180C200002E 0: Forward 1: Discard 2: Peer |
| 1.3.6.1.4.1.4756.20.502.20.1.1696 | ColumnnidL2CPPort1DMAC0180C200002FRemoteB | read-write | current | NID Series card Port 1 L2CP Mode 0180C200002F 0: Forward 1: Discard 1: Peer |
| 1.3.6.1.4.1.4756.20.502.20.1.1697 | ColumnnidL2CPPort2DMAC0180C2000000RemoteB | read-write | current | NID Series card Port 2 L2CP Mode 0180C2000000 0: Forward 1: Discard 2: Peer |
| 1.3.6.1.4.1.4756.20.502.20.1.1698 | ColumnnidL2CPPort2DMAC0180C2000001RemoteB | read-write | current | NID Series card Port 2 L2CP Mode 0180C2000001 0: Forward 1: Discard 2: Peer |
| 1.3.6.1.4.1.4756.20.502.20.1.1699 | ColumnnidL2CPPort2DMAC0180C2000002RemoteB | read-write | current | NID Series card Port 2 L2CP Mode 0180C2000002 0: Forward 1: Discard 2: Peer |
| 1.3.6.1.4.1.4756.20.502.20.1.1700 | ColumnnidL2CPPort2DMAC0180C2000003RemoteB | read-write | current | NID Series card Port 2 L2CP Mode 0180C2000003 0: Forward 1: Discard 2: Peer |
| 1.3.6.1.4.1.4756.20.502.20.1.1701 | ColumnnidL2CPPort2DMAC0180C2000004RemoteB | read-write | current | NID Series card Port 2 L2CP Mode 0180C2000004 0: Forward 1: Discard 2: Peer |
| 1.3.6.1.4.1.4756.20.502.20.1.1702 | ColumnnidL2CPPort2DMAC0180C2000005RemoteB | read-write | current | NID Series card Port 2 L2CP Mode 0180C2000005 0: Forward 1: Discard 2: Peer |
| 1.3.6.1.4.1.4756.20.502.20.1.1703 | ColumnnidL2CPPort2DMAC0180C2000006RemoteB | read-write | current | NID Series card Port 2 L2CP Mode 0180C2000006 0: Forward 1: Discard 2: Peer |
| 1.3.6.1.4.1.4756.20.502.20.1.1704 | ColumnnidL2CPPort2DMAC0180C2000007RemoteB | read-write | current | NID Series card Port 2 L2CP Mode 0180C2000007 0: Forward 1: Discard 2: Peer |
| 1.3.6.1.4.1.4756.20.502.20.1.1705 | ColumnnidL2CPPort2DMAC0180C2000008RemoteB | read-write | current | NID Series card Port 2 L2CP Mode 0180C2000008 0: Forward 1: Discard 2: Peer |
| 1.3.6.1.4.1.4756.20.502.20.1.1706 | ColumnnidL2CPPort2DMAC0180C2000009RemoteB | read-write | current | NID Series card Port 2 L2CP Mode 0180C2000009 0: Forward 1: Discard 2: Peer |
| 1.3.6.1.4.1.4756.20.502.20.1.1707 | ColumnnidL2CPPort2DMAC0180C200000ARemoteB | read-write | current | NID Series card Port 2 L2CP Mode 0180C200000A 0: Forward 1: Discard 2: Peer |
| 1.3.6.1.4.1.4756.20.502.20.1.1708 | ColumnnidL2CPPort2DMAC0180C200000BRemoteB | read-write | current | NID Series card Port 2 L2CP Mode 0180C200000B 0: Forward 1: Discard 2: Peer |
| 1.3.6.1.4.1.4756.20.502.20.1.1709 | ColumnnidL2CPPort2DMAC0180C200000CRemoteB | read-write | current | NID Series card Port 2 L2CP Mode 0180C200000C 0: Forward 1: Discard 2: Peer |
| 1.3.6.1.4.1.4756.20.502.20.1.1710 | ColumnnidL2CPPort2DMAC0180C200000DRemoteB | read-write | current | NID Series card Port 2 L2CP Mode 0180C200000D 0: Forward 1: Discard 2: Peer |
| 1.3.6.1.4.1.4756.20.502.20.1.1711 | ColumnnidL2CPPort2DMAC0180C200000ERemoteB | read-write | current | NID Series card Port 2 L2CP Mode 0180C200000E 0: Forward 1: Discard 2: Peer |
| 1.3.6.1.4.1.4756.20.502.20.1.1712 | ColumnnidL2CPPort2DMAC0180C200000FRemoteB | read-write | current | NID Series card Port 2 L2CP Mode 0180C200000F 0: Forward 1: Discard 2: Peer |
| 1.3.6.1.4.1.4756.20.502.20.1.1713 | ColumnnidL2CPPort2DMAC0180C2000010RemoteB | read-write | current | NID Series card Port 2 L2CP Mode 0180C2000010 0: Forward 1: Discard 2: Peer |
| 1.3.6.1.4.1.4756.20.502.20.1.1714 | ColumnnidL2CPPort2DMAC0180C2000020RemoteB | read-write | current | NID Series card Port 2 L2CP Mode 0180C2000020 0: Forward 1: Discard 2: Peer |
| 1.3.6.1.4.1.4756.20.502.20.1.1715 | ColumnnidL2CPPort2DMAC0180C2000021RemoteB | read-write | current | NID Series card Port 2 L2CP Mode 0180C2000021 0: Forward 1: Discard 2: Peer |
| 1.3.6.1.4.1.4756.20.502.20.1.1716 | ColumnnidL2CPPort2DMAC0180C2000022RemoteB | read-write | current | NID Series card Port 2 L2CP Mode 0180C2000022 0: Forward 1: Discard 2: Peer |
| 1.3.6.1.4.1.4756.20.502.20.1.1717 | ColumnnidL2CPPort2DMAC0180C2000023RemoteB | read-write | current | NID Series card Port 2 L2CP Mode 0180C2000023 0: Forward 1: Discard 2: Peer |
| 1.3.6.1.4.1.4756.20.502.20.1.1718 | ColumnnidL2CPPort2DMAC0180C2000024RemoteB | read-write | current | NID Series card Port 2 L2CP Mode 0180C2000024 0: Forward 1: Discard 2: Peer |
| 1.3.6.1.4.1.4756.20.502.20.1.1719 | ColumnnidL2CPPort2DMAC0180C2000025RemoteB | read-write | current | NID Series card Port 2 L2CP Mode 0180C2000025 0: Forward 1: Discard 2: Peer |
| 1.3.6.1.4.1.4756.20.502.20.1.1720 | ColumnnidL2CPPort2DMAC0180C2000026RemoteB | read-write | current | NID Series card Port 2 L2CP Mode 0180C2000026 0: Forward 1: Discard 2: Peer |
| 1.3.6.1.4.1.4756.20.502.20.1.1721 | ColumnnidL2CPPort2DMAC0180C2000027RemoteB | read-write | current | NID Series card Port 2 L2CP Mode 0180C2000027 0: Forward 1: Discard 2: Peer |
| 1.3.6.1.4.1.4756.20.502.20.1.1722 | ColumnnidL2CPPort2DMAC0180C2000028RemoteB | read-write | current | NID Series card Port 2 L2CP Mode 0180C2000028 0: Forward 1: Discard 2: Peer |
| 1.3.6.1.4.1.4756.20.502.20.1.1723 | ColumnnidL2CPPort2DMAC0180C2000029RemoteB | read-write | current | NID Series card Port 2 L2CP Mode 0180C2000029 0: Forward 1: Discard 2: Peer |
| 1.3.6.1.4.1.4756.20.502.20.1.1724 | ColumnnidL2CPPort2DMAC0180C200002ARemoteB | read-write | current | NID Series card Port 2 L2CP Mode 0180C200002A 0: Forward 1: Discard 2: Peer |
| 1.3.6.1.4.1.4756.20.502.20.1.1725 | ColumnnidL2CPPort2DMAC0180C200002BRemoteB | read-write | current | NID Series card Port 2 L2CP Mode 0180C200002B 0: Forward 1: Discard 2: Peer |
| 1.3.6.1.4.1.4756.20.502.20.1.1726 | ColumnnidL2CPPort2DMAC0180C200002CRemoteB | read-write | current | NID Series card Port 2 L2CP Mode 0180C200002C 0: Forward 1: Discard 2: Peer |
| 1.3.6.1.4.1.4756.20.502.20.1.1727 | ColumnnidL2CPPort2DMAC0180C200002DRemoteB | read-write | current | NID Series card Port 2 L2CP Mode 0180C200002D 0: Forward 1: Discard 2: Peer |
| 1.3.6.1.4.1.4756.20.502.20.1.1728 | ColumnnidL2CPPort2DMAC0180C200002ERemoteB | read-write | current | NID Series card Port 2 L2CP Mode 0180C200002E 0: Forward 1: Discard 2: Peer |
| 1.3.6.1.4.1.4756.20.502.20.1.1729 | ColumnnidL2CPPort2DMAC0180C200002FRemoteB | read-write | current | NID Series card Port 2 L2CP Mode 0180C200002F 0: Forward 1: Discard 1: Peer |
| 1.3.6.1.4.1.4756.20.502.20.1.1730 | ColumnnidL2CPPort3DMAC0180C2000000RemoteB | read-write | current | NID Series card Port 3 L2CP Mode 0180C2000000 0: Forward 1: Discard 2: Peer |
| 1.3.6.1.4.1.4756.20.502.20.1.1731 | ColumnnidL2CPPort3DMAC0180C2000001RemoteB | read-write | current | NID Series card Port 3 L2CP Mode 0180C2000001 0: Forward 1: Discard 2: Peer |
| 1.3.6.1.4.1.4756.20.502.20.1.1732 | ColumnnidL2CPPort3DMAC0180C2000002RemoteB | read-write | current | NID Series card Port 3 L2CP Mode 0180C2000002 0: Forward 1: Discard 2: Peer |
| 1.3.6.1.4.1.4756.20.502.20.1.1733 | ColumnnidL2CPPort3DMAC0180C2000003RemoteB | read-write | current | NID Series card Port 3 L2CP Mode 0180C2000003 0: Forward 1: Discard 2: Peer |
| 1.3.6.1.4.1.4756.20.502.20.1.1734 | ColumnnidL2CPPort3DMAC0180C2000004RemoteB | read-write | current | NID Series card Port 3 L2CP Mode 0180C2000004 0: Forward 1: Discard 2: Peer |
| 1.3.6.1.4.1.4756.20.502.20.1.1735 | ColumnnidL2CPPort3DMAC0180C2000005RemoteB | read-write | current | NID Series card Port 3 L2CP Mode 0180C2000005 0: Forward 1: Discard 2: Peer |
| 1.3.6.1.4.1.4756.20.502.20.1.1736 | ColumnnidL2CPPort3DMAC0180C2000006RemoteB | read-write | current | NID Series card Port 3 L2CP Mode 0180C2000006 0: Forward 1: Discard 2: Peer |
| 1.3.6.1.4.1.4756.20.502.20.1.1737 | ColumnnidL2CPPort3DMAC0180C2000007RemoteB | read-write | current | NID Series card Port 3 L2CP Mode 0180C2000007 0: Forward 1: Discard 2: Peer |
| 1.3.6.1.4.1.4756.20.502.20.1.1738 | ColumnnidL2CPPort3DMAC0180C2000008RemoteB | read-write | current | NID Series card Port 3 L2CP Mode 0180C2000008 0: Forward 1: Discard 2: Peer |
| 1.3.6.1.4.1.4756.20.502.20.1.1739 | ColumnnidL2CPPort3DMAC0180C2000009RemoteB | read-write | current | NID Series card Port 3 L2CP Mode 0180C2000009 0: Forward 1: Discard 2: Peer |
| 1.3.6.1.4.1.4756.20.502.20.1.1740 | ColumnnidL2CPPort3DMAC0180C200000ARemoteB | read-write | current | NID Series card Port 3 L2CP Mode 0180C200000A 0: Forward 1: Discard 2: Peer |
| 1.3.6.1.4.1.4756.20.502.20.1.1741 | ColumnnidL2CPPort3DMAC0180C200000BRemoteB | read-write | current | NID Series card Port 3 L2CP Mode 0180C200000B 0: Forward 1: Discard 2: Peer |
| 1.3.6.1.4.1.4756.20.502.20.1.1742 | ColumnnidL2CPPort3DMAC0180C200000CRemoteB | read-write | current | NID Series card Port 3 L2CP Mode 0180C200000C 0: Forward 1: Discard 2: Peer |
| 1.3.6.1.4.1.4756.20.502.20.1.1743 | ColumnnidL2CPPort3DMAC0180C200000DRemoteB | read-write | current | NID Series card Port 3 L2CP Mode 0180C200000D 0: Forward 1: Discard 2: Peer |
| 1.3.6.1.4.1.4756.20.502.20.1.1744 | ColumnnidL2CPPort3DMAC0180C200000ERemoteB | read-write | current | NID Series card Port 3 L2CP Mode 0180C200000E 0: Forward 1: Discard 2: Peer |
| 1.3.6.1.4.1.4756.20.502.20.1.1745 | ColumnnidL2CPPort3DMAC0180C200000FRemoteB | read-write | current | NID Series card Port 3 L2CP Mode 0180C200000F 0: Forward 1: Discard 2: Peer |
| 1.3.6.1.4.1.4756.20.502.20.1.1746 | ColumnnidL2CPPort3DMAC0180C2000010RemoteB | read-write | current | NID Series card Port 3 L2CP Mode 0180C2000010 0: Forward 1: Discard 2: Peer |
| 1.3.6.1.4.1.4756.20.502.20.1.1747 | ColumnnidL2CPPort3DMAC0180C2000020RemoteB | read-write | current | NID Series card Port 3 L2CP Mode 0180C2000020 0: Forward 1: Discard 2: Peer |
| 1.3.6.1.4.1.4756.20.502.20.1.1748 | ColumnnidL2CPPort3DMAC0180C2000021RemoteB | read-write | current | NID Series card Port 3 L2CP Mode 0180C2000021 0: Forward 1: Discard 2: Peer |
| 1.3.6.1.4.1.4756.20.502.20.1.1749 | ColumnnidL2CPPort3DMAC0180C2000022RemoteB | read-write | current | NID Series card Port 3 L2CP Mode 0180C2000022 0: Forward 1: Discard 2: Peer |
| 1.3.6.1.4.1.4756.20.502.20.1.1750 | ColumnnidL2CPPort3DMAC0180C2000023RemoteB | read-write | current | NID Series card Port 3 L2CP Mode 0180C2000023 0: Forward 1: Discard 2: Peer |
| 1.3.6.1.4.1.4756.20.502.20.1.1751 | ColumnnidL2CPPort3DMAC0180C2000024RemoteB | read-write | current | NID Series card Port 3 L2CP Mode 0180C2000024 0: Forward 1: Discard 2: Peer |
| 1.3.6.1.4.1.4756.20.502.20.1.1752 | ColumnnidL2CPPort3DMAC0180C2000025RemoteB | read-write | current | NID Series card Port 3 L2CP Mode 0180C2000025 0: Forward 1: Discard 2: Peer |
| 1.3.6.1.4.1.4756.20.502.20.1.1753 | ColumnnidL2CPPort3DMAC0180C2000026RemoteB | read-write | current | NID Series card Port 3 L2CP Mode 0180C2000026 0: Forward 1: Discard 2: Peer |
| 1.3.6.1.4.1.4756.20.502.20.1.1754 | ColumnnidL2CPPort3DMAC0180C2000027RemoteB | read-write | current | NID Series card Port 3 L2CP Mode 0180C2000027 0: Forward 1: Discard 2: Peer |
| 1.3.6.1.4.1.4756.20.502.20.1.1755 | ColumnnidL2CPPort3DMAC0180C2000028RemoteB | read-write | current | NID Series card Port 3 L2CP Mode 0180C2000028 0: Forward 1: Discard 2: Peer |
| 1.3.6.1.4.1.4756.20.502.20.1.1756 | ColumnnidL2CPPort3DMAC0180C2000029RemoteB | read-write | current | NID Series card Port 3 L2CP Mode 0180C2000029 0: Forward 1: Discard 2: Peer |
| 1.3.6.1.4.1.4756.20.502.20.1.1757 | ColumnnidL2CPPort3DMAC0180C200002ARemoteB | read-write | current | NID Series card Port 3 L2CP Mode 0180C200002A 0: Forward 1: Discard 2: Peer |
| 1.3.6.1.4.1.4756.20.502.20.1.1758 | ColumnnidL2CPPort3DMAC0180C200002BRemoteB | read-write | current | NID Series card Port 3 L2CP Mode 0180C200002B 0: Forward 1: Discard 2: Peer |
| 1.3.6.1.4.1.4756.20.502.20.1.1759 | ColumnnidL2CPPort3DMAC0180C200002CRemoteB | read-write | current | NID Series card Port 3 L2CP Mode 0180C200002C 0: Forward 1: Discard 2: Peer |
| 1.3.6.1.4.1.4756.20.502.20.1.1760 | ColumnnidL2CPPort3DMAC0180C200002DRemoteB | read-write | current | NID Series card Port 3 L2CP Mode 0180C200002D 0: Forward 1: Discard 2: Peer |
| 1.3.6.1.4.1.4756.20.502.20.1.1761 | ColumnnidL2CPPort3DMAC0180C200002ERemoteB | read-write | current | NID Series card Port 3 L2CP Mode 0180C200002E 0: Forward 1: Discard 2: Peer |
| 1.3.6.1.4.1.4756.20.502.20.1.1762 | ColumnnidL2CPPort3DMAC0180C200002FRemoteB | read-write | current | NID Series card Port 3 L2CP Mode 0180C200002F 0: Forward 1: Discard 1: Peer |
| 1.3.6.1.4.1.4756.20.502.20.1.1763 | ColumnnidL2CPPort4DMAC0180C2000000RemoteB | read-write | current | NID Series card Port 4 L2CP Mode 0180C2000000 0: Forward 1: Discard 2: Peer |
| 1.3.6.1.4.1.4756.20.502.20.1.1764 | ColumnnidL2CPPort4DMAC0180C2000001RemoteB | read-write | current | NID Series card Port 4 L2CP Mode 0180C2000001 0: Forward 1: Discard 2: Peer |
| 1.3.6.1.4.1.4756.20.502.20.1.1765 | ColumnnidL2CPPort4DMAC0180C2000002RemoteB | read-write | current | NID Series card Port 4 L2CP Mode 0180C2000002 0: Forward 1: Discard 2: Peer |
| 1.3.6.1.4.1.4756.20.502.20.1.1766 | ColumnnidL2CPPort4DMAC0180C2000003RemoteB | read-write | current | NID Series card Port 4 L2CP Mode 0180C2000003 0: Forward 1: Discard 2: Peer |
| 1.3.6.1.4.1.4756.20.502.20.1.1767 | ColumnnidL2CPPort4DMAC0180C2000004RemoteB | read-write | current | NID Series card Port 4 L2CP Mode 0180C2000004 0: Forward 1: Discard 2: Peer |
| 1.3.6.1.4.1.4756.20.502.20.1.1768 | ColumnnidL2CPPort4DMAC0180C2000005RemoteB | read-write | current | NID Series card Port 4 L2CP Mode 0180C2000005 0: Forward 1: Discard 2: Peer |
| 1.3.6.1.4.1.4756.20.502.20.1.1769 | ColumnnidL2CPPort4DMAC0180C2000006RemoteB | read-write | current | NID Series card Port 4 L2CP Mode 0180C2000006 0: Forward 1: Discard 2: Peer |
| 1.3.6.1.4.1.4756.20.502.20.1.1770 | ColumnnidL2CPPort4DMAC0180C2000007RemoteB | read-write | current | NID Series card Port 4 L2CP Mode 0180C2000007 0: Forward 1: Discard 2: Peer |
| 1.3.6.1.4.1.4756.20.502.20.1.1771 | ColumnnidL2CPPort4DMAC0180C2000008RemoteB | read-write | current | NID Series card Port 4 L2CP Mode 0180C2000008 0: Forward 1: Discard 2: Peer |
| 1.3.6.1.4.1.4756.20.502.20.1.1772 | ColumnnidL2CPPort4DMAC0180C2000009RemoteB | read-write | current | NID Series card Port 4 L2CP Mode 0180C2000009 0: Forward 1: Discard 2: Peer |
| 1.3.6.1.4.1.4756.20.502.20.1.1773 | ColumnnidL2CPPort4DMAC0180C200000ARemoteB | read-write | current | NID Series card Port 4 L2CP Mode 0180C200000A 0: Forward 1: Discard 2: Peer |
| 1.3.6.1.4.1.4756.20.502.20.1.1774 | ColumnnidL2CPPort4DMAC0180C200000BRemoteB | read-write | current | NID Series card Port 4 L2CP Mode 0180C200000B 0: Forward 1: Discard 2: Peer |
| 1.3.6.1.4.1.4756.20.502.20.1.1775 | ColumnnidL2CPPort4DMAC0180C200000CRemoteB | read-write | current | NID Series card Port 4 L2CP Mode 0180C200000C 0: Forward 1: Discard 2: Peer |
| 1.3.6.1.4.1.4756.20.502.20.1.1776 | ColumnnidL2CPPort4DMAC0180C200000DRemoteB | read-write | current | NID Series card Port 4 L2CP Mode 0180C200000D 0: Forward 1: Discard 2: Peer |
| 1.3.6.1.4.1.4756.20.502.20.1.1777 | ColumnnidL2CPPort4DMAC0180C200000ERemoteB | read-write | current | NID Series card Port 4 L2CP Mode 0180C200000E 0: Forward 1: Discard 2: Peer |
| 1.3.6.1.4.1.4756.20.502.20.1.1778 | ColumnnidL2CPPort4DMAC0180C200000FRemoteB | read-write | current | NID Series card Port 4 L2CP Mode 0180C200000F 0: Forward 1: Discard 2: Peer |
| 1.3.6.1.4.1.4756.20.502.20.1.1779 | ColumnnidL2CPPort4DMAC0180C2000010RemoteB | read-write | current | NID Series card Port 4 L2CP Mode 0180C2000010 0: Forward 1: Discard 2: Peer |
| 1.3.6.1.4.1.4756.20.502.20.1.1780 | ColumnnidL2CPPort4DMAC0180C2000020RemoteB | read-write | current | NID Series card Port 4 L2CP Mode 0180C2000020 0: Forward 1: Discard 2: Peer |
| 1.3.6.1.4.1.4756.20.502.20.1.1781 | ColumnnidL2CPPort4DMAC0180C2000021RemoteB | read-write | current | NID Series card Port 4 L2CP Mode 0180C2000021 0: Forward 1: Discard 2: Peer |
| 1.3.6.1.4.1.4756.20.502.20.1.1782 | ColumnnidL2CPPort4DMAC0180C2000022RemoteB | read-write | current | NID Series card Port 4 L2CP Mode 0180C2000022 0: Forward 1: Discard 2: Peer |
| 1.3.6.1.4.1.4756.20.502.20.1.1783 | ColumnnidL2CPPort4DMAC0180C2000023RemoteB | read-write | current | NID Series card Port 4 L2CP Mode 0180C2000023 0: Forward 1: Discard 2: Peer |
| 1.3.6.1.4.1.4756.20.502.20.1.1784 | ColumnnidL2CPPort4DMAC0180C2000024RemoteB | read-write | current | NID Series card Port 4 L2CP Mode 0180C2000024 0: Forward 1: Discard 2: Peer |
| 1.3.6.1.4.1.4756.20.502.20.1.1785 | ColumnnidL2CPPort4DMAC0180C2000025RemoteB | read-write | current | NID Series card Port 4 L2CP Mode 0180C2000025 0: Forward 1: Discard 2: Peer |
| 1.3.6.1.4.1.4756.20.502.20.1.1786 | ColumnnidL2CPPort4DMAC0180C2000026RemoteB | read-write | current | NID Series card Port 4 L2CP Mode 0180C2000026 0: Forward 1: Discard 2: Peer |
| 1.3.6.1.4.1.4756.20.502.20.1.1787 | ColumnnidL2CPPort4DMAC0180C2000027RemoteB | read-write | current | NID Series card Port 4 L2CP Mode 0180C2000027 0: Forward 1: Discard 2: Peer |
| 1.3.6.1.4.1.4756.20.502.20.1.1788 | ColumnnidL2CPPort4DMAC0180C2000028RemoteB | read-write | current | NID Series card Port 4 L2CP Mode 0180C2000028 0: Forward 1: Discard 2: Peer |
| 1.3.6.1.4.1.4756.20.502.20.1.1789 | ColumnnidL2CPPort4DMAC0180C2000029RemoteB | read-write | current | NID Series card Port 4 L2CP Mode 0180C2000029 0: Forward 1: Discard 2: Peer |
| 1.3.6.1.4.1.4756.20.502.20.1.1790 | ColumnnidL2CPPort4DMAC0180C200002ARemoteB | read-write | current | NID Series card Port 4 L2CP Mode 0180C200002A 0: Forward 1: Discard 2: Peer |
| 1.3.6.1.4.1.4756.20.502.20.1.1791 | ColumnnidL2CPPort4DMAC0180C200002BRemoteB | read-write | current | NID Series card Port 4 L2CP Mode 0180C200002B 0: Forward 1: Discard 2: Peer |
| 1.3.6.1.4.1.4756.20.502.20.1.1792 | ColumnnidL2CPPort4DMAC0180C200002CRemoteB | read-write | current | NID Series card Port 4 L2CP Mode 0180C200002C 0: Forward 1: Discard 2: Peer |
| 1.3.6.1.4.1.4756.20.502.20.1.1793 | ColumnnidL2CPPort4DMAC0180C200002DRemoteB | read-write | current | NID Series card Port 4 L2CP Mode 0180C200002D 0: Forward 1: Discard 2: Peer |
| 1.3.6.1.4.1.4756.20.502.20.1.1794 | ColumnnidL2CPPort4DMAC0180C200002ERemoteB | read-write | current | NID Series card Port 4 L2CP Mode 0180C200002E 0: Forward 1: Discard 2: Peer |
| 1.3.6.1.4.1.4756.20.502.20.1.1795 | ColumnnidL2CPPort4DMAC0180C200002FRemoteB | read-write | current | NID Series card Port 4 L2CP Mode 0180C200002F 0: Forward 1: Discard 1: Peer |
| 1.3.6.1.4.1.4756.20.502.20.1.1796 | ColumnnidL2CPPort5DMAC0180C2000000RemoteB | read-write | current | NID Series card Port 5 L2CP Mode 0180C2000000 0: Forward 1: Discard 2: Peer |
| 1.3.6.1.4.1.4756.20.502.20.1.1797 | ColumnnidL2CPPort5DMAC0180C2000001RemoteB | read-write | current | NID Series card Port 5 L2CP Mode 0180C2000001 0: Forward 1: Discard 2: Peer |
| 1.3.6.1.4.1.4756.20.502.20.1.1798 | ColumnnidL2CPPort5DMAC0180C2000002RemoteB | read-write | current | NID Series card Port 5 L2CP Mode 0180C2000002 0: Forward 1: Discard 2: Peer |
| 1.3.6.1.4.1.4756.20.502.20.1.1799 | ColumnnidL2CPPort5DMAC0180C2000003RemoteB | read-write | current | NID Series card Port 5 L2CP Mode 0180C2000003 0: Forward 1: Discard 2: Peer |
| 1.3.6.1.4.1.4756.20.502.20.1.1800 | ColumnnidL2CPPort5DMAC0180C2000004RemoteB | read-write | current | NID Series card Port 5 L2CP Mode 0180C2000004 0: Forward 1: Discard 2: Peer |
| 1.3.6.1.4.1.4756.20.502.20.1.1801 | ColumnnidL2CPPort5DMAC0180C2000005RemoteB | read-write | current | NID Series card Port 5 L2CP Mode 0180C2000005 0: Forward 1: Discard 2: Peer |
| 1.3.6.1.4.1.4756.20.502.20.1.1802 | ColumnnidL2CPPort5DMAC0180C2000006RemoteB | read-write | current | NID Series card Port 5 L2CP Mode 0180C2000006 0: Forward 1: Discard 2: Peer |
| 1.3.6.1.4.1.4756.20.502.20.1.1803 | ColumnnidL2CPPort5DMAC0180C2000007RemoteB | read-write | current | NID Series card Port 5 L2CP Mode 0180C2000007 0: Forward 1: Discard 2: Peer |
| 1.3.6.1.4.1.4756.20.502.20.1.1804 | ColumnnidL2CPPort5DMAC0180C2000008RemoteB | read-write | current | NID Series card Port 5 L2CP Mode 0180C2000008 0: Forward 1: Discard 2: Peer |
| 1.3.6.1.4.1.4756.20.502.20.1.1805 | ColumnnidL2CPPort5DMAC0180C2000009RemoteB | read-write | current | NID Series card Port 5 L2CP Mode 0180C2000009 0: Forward 1: Discard 2: Peer |
| 1.3.6.1.4.1.4756.20.502.20.1.1806 | ColumnnidL2CPPort5DMAC0180C200000ARemoteB | read-write | current | NID Series card Port 5 L2CP Mode 0180C200000A 0: Forward 1: Discard 2: Peer |
| 1.3.6.1.4.1.4756.20.502.20.1.1807 | ColumnnidL2CPPort5DMAC0180C200000BRemoteB | read-write | current | NID Series card Port 5 L2CP Mode 0180C200000B 0: Forward 1: Discard 2: Peer |
| 1.3.6.1.4.1.4756.20.502.20.1.1808 | ColumnnidL2CPPort5DMAC0180C200000CRemoteB | read-write | current | NID Series card Port 5 L2CP Mode 0180C200000C 0: Forward 1: Discard 2: Peer |
| 1.3.6.1.4.1.4756.20.502.20.1.1809 | ColumnnidL2CPPort5DMAC0180C200000DRemoteB | read-write | current | NID Series card Port 5 L2CP Mode 0180C200000D 0: Forward 1: Discard 2: Peer |
| 1.3.6.1.4.1.4756.20.502.20.1.1810 | ColumnnidL2CPPort5DMAC0180C200000ERemoteB | read-write | current | NID Series card Port 5 L2CP Mode 0180C200000E 0: Forward 1: Discard 2: Peer |
| 1.3.6.1.4.1.4756.20.502.20.1.1811 | ColumnnidL2CPPort5DMAC0180C200000FRemoteB | read-write | current | NID Series card Port 5 L2CP Mode 0180C200000F 0: Forward 1: Discard 2: Peer |
| 1.3.6.1.4.1.4756.20.502.20.1.1812 | ColumnnidL2CPPort5DMAC0180C2000010RemoteB | read-write | current | NID Series card Port 5 L2CP Mode 0180C2000010 0: Forward 1: Discard 2: Peer |
| 1.3.6.1.4.1.4756.20.502.20.1.1813 | ColumnnidL2CPPort5DMAC0180C2000020RemoteB | read-write | current | NID Series card Port 5 L2CP Mode 0180C2000020 0: Forward 1: Discard 2: Peer |
| 1.3.6.1.4.1.4756.20.502.20.1.1814 | ColumnnidL2CPPort5DMAC0180C2000021RemoteB | read-write | current | NID Series card Port 5 L2CP Mode 0180C2000021 0: Forward 1: Discard 2: Peer |
| 1.3.6.1.4.1.4756.20.502.20.1.1815 | ColumnnidL2CPPort5DMAC0180C2000022RemoteB | read-write | current | NID Series card Port 5 L2CP Mode 0180C2000022 0: Forward 1: Discard 2: Peer |
| 1.3.6.1.4.1.4756.20.502.20.1.1816 | ColumnnidL2CPPort5DMAC0180C2000023RemoteB | read-write | current | NID Series card Port 5 L2CP Mode 0180C2000023 0: Forward 1: Discard 2: Peer |
| 1.3.6.1.4.1.4756.20.502.20.1.1817 | ColumnnidL2CPPort5DMAC0180C2000024RemoteB | read-write | current | NID Series card Port 5 L2CP Mode 0180C2000024 0: Forward 1: Discard 2: Peer |
| 1.3.6.1.4.1.4756.20.502.20.1.1818 | ColumnnidL2CPPort5DMAC0180C2000025RemoteB | read-write | current | NID Series card Port 5 L2CP Mode 0180C2000025 0: Forward 1: Discard 2: Peer |
| 1.3.6.1.4.1.4756.20.502.20.1.1819 | ColumnnidL2CPPort5DMAC0180C2000026RemoteB | read-write | current | NID Series card Port 5 L2CP Mode 0180C2000026 0: Forward 1: Discard 2: Peer |
| 1.3.6.1.4.1.4756.20.502.20.1.1820 | ColumnnidL2CPPort5DMAC0180C2000027RemoteB | read-write | current | NID Series card Port 5 L2CP Mode 0180C2000027 0: Forward 1: Discard 2: Peer |
| 1.3.6.1.4.1.4756.20.502.20.1.1821 | ColumnnidL2CPPort5DMAC0180C2000028RemoteB | read-write | current | NID Series card Port 5 L2CP Mode 0180C2000028 0: Forward 1: Discard 2: Peer |
| 1.3.6.1.4.1.4756.20.502.20.1.1822 | ColumnnidL2CPPort5DMAC0180C2000029RemoteB | read-write | current | NID Series card Port 5 L2CP Mode 0180C2000029 0: Forward 1: Discard 2: Peer |
| 1.3.6.1.4.1.4756.20.502.20.1.1823 | ColumnnidL2CPPort5DMAC0180C200002ARemoteB | read-write | current | NID Series card Port 5 L2CP Mode 0180C200002A 0: Forward 1: Discard 2: Peer |
| 1.3.6.1.4.1.4756.20.502.20.1.1824 | ColumnnidL2CPPort5DMAC0180C200002BRemoteB | read-write | current | NID Series card Port 5 L2CP Mode 0180C200002B 0: Forward 1: Discard 2: Peer |
| 1.3.6.1.4.1.4756.20.502.20.1.1825 | ColumnnidL2CPPort5DMAC0180C200002CRemoteB | read-write | current | NID Series card Port 5 L2CP Mode 0180C200002C 0: Forward 1: Discard 2: Peer |
| 1.3.6.1.4.1.4756.20.502.20.1.1826 | ColumnnidL2CPPort5DMAC0180C200002DRemoteB | read-write | current | NID Series card Port 5 L2CP Mode 0180C200002D 0: Forward 1: Discard 2: Peer |
| 1.3.6.1.4.1.4756.20.502.20.1.1827 | ColumnnidL2CPPort5DMAC0180C200002ERemoteB | read-write | current | NID Series card Port 5 L2CP Mode 0180C200002E 0: Forward 1: Discard 2: Peer |
| 1.3.6.1.4.1.4756.20.502.20.1.1828 | ColumnnidL2CPPort5DMAC0180C200002FRemoteB | read-write | current | NID Series card Port 5 L2CP Mode 0180C200002F 0: Forward 1: Discard 1: Peer |
| 1.3.6.1.4.1.4756.20.502.20.1.1829 | ColumnnidL2CPPort6DMAC0180C2000000RemoteB | read-write | current | NID Series card Port 6 L2CP Mode 0180C2000000 0: Forward 1: Discard 2: Peer |
| 1.3.6.1.4.1.4756.20.502.20.1.1830 | ColumnnidL2CPPort6DMAC0180C2000001RemoteB | read-write | current | NID Series card Port 6 L2CP Mode 0180C2000001 0: Forward 1: Discard 2: Peer |
| 1.3.6.1.4.1.4756.20.502.20.1.1831 | ColumnnidL2CPPort6DMAC0180C2000002RemoteB | read-write | current | NID Series card Port 6 L2CP Mode 0180C2000002 0: Forward 1: Discard 2: Peer |
| 1.3.6.1.4.1.4756.20.502.20.1.1832 | ColumnnidL2CPPort6DMAC0180C2000003RemoteB | read-write | current | NID Series card Port 6 L2CP Mode 0180C2000003 0: Forward 1: Discard 2: Peer |
| 1.3.6.1.4.1.4756.20.502.20.1.1833 | ColumnnidL2CPPort6DMAC0180C2000004RemoteB | read-write | current | NID Series card Port 6 L2CP Mode 0180C2000004 0: Forward 1: Discard 2: Peer |
| 1.3.6.1.4.1.4756.20.502.20.1.1834 | ColumnnidL2CPPort6DMAC0180C2000005RemoteB | read-write | current | NID Series card Port 6 L2CP Mode 0180C2000005 0: Forward 1: Discard 2: Peer |
| 1.3.6.1.4.1.4756.20.502.20.1.1835 | ColumnnidL2CPPort6DMAC0180C2000006RemoteB | read-write | current | NID Series card Port 6 L2CP Mode 0180C2000006 0: Forward 1: Discard 2: Peer |
| 1.3.6.1.4.1.4756.20.502.20.1.1836 | ColumnnidL2CPPort6DMAC0180C2000007RemoteB | read-write | current | NID Series card Port 6 L2CP Mode 0180C2000007 0: Forward 1: Discard 2: Peer |
| 1.3.6.1.4.1.4756.20.502.20.1.1837 | ColumnnidL2CPPort6DMAC0180C2000008RemoteB | read-write | current | NID Series card Port 6 L2CP Mode 0180C2000008 0: Forward 1: Discard 2: Peer |
| 1.3.6.1.4.1.4756.20.502.20.1.1838 | ColumnnidL2CPPort6DMAC0180C2000009RemoteB | read-write | current | NID Series card Port 6 L2CP Mode 0180C2000009 0: Forward 1: Discard 2: Peer |
| 1.3.6.1.4.1.4756.20.502.20.1.1839 | ColumnnidL2CPPort6DMAC0180C200000ARemoteB | read-write | current | NID Series card Port 6 L2CP Mode 0180C200000A 0: Forward 1: Discard 2: Peer |
| 1.3.6.1.4.1.4756.20.502.20.1.1840 | ColumnnidL2CPPort6DMAC0180C200000BRemoteB | read-write | current | NID Series card Port 6 L2CP Mode 0180C200000B 0: Forward 1: Discard 2: Peer |
| 1.3.6.1.4.1.4756.20.502.20.1.1841 | ColumnnidL2CPPort6DMAC0180C200000CRemoteB | read-write | current | NID Series card Port 6 L2CP Mode 0180C200000C 0: Forward 1: Discard 2: Peer |
| 1.3.6.1.4.1.4756.20.502.20.1.1842 | ColumnnidL2CPPort6DMAC0180C200000DRemoteB | read-write | current | NID Series card Port 6 L2CP Mode 0180C200000D 0: Forward 1: Discard 2: Peer |
| 1.3.6.1.4.1.4756.20.502.20.1.1843 | ColumnnidL2CPPort6DMAC0180C200000ERemoteB | read-write | current | NID Series card Port 6 L2CP Mode 0180C200000E 0: Forward 1: Discard 2: Peer |
| 1.3.6.1.4.1.4756.20.502.20.1.1844 | ColumnnidL2CPPort6DMAC0180C200000FRemoteB | read-write | current | NID Series card Port 6 L2CP Mode 0180C200000F 0: Forward 1: Discard 2: Peer |
| 1.3.6.1.4.1.4756.20.502.20.1.1845 | ColumnnidL2CPPort6DMAC0180C2000010RemoteB | read-write | current | NID Series card Port 6 L2CP Mode 0180C2000010 0: Forward 1: Discard 2: Peer |
| 1.3.6.1.4.1.4756.20.502.20.1.1846 | ColumnnidL2CPPort6DMAC0180C2000020RemoteB | read-write | current | NID Series card Port 6 L2CP Mode 0180C2000020 0: Forward 1: Discard 2: Peer |
| 1.3.6.1.4.1.4756.20.502.20.1.1847 | ColumnnidL2CPPort6DMAC0180C2000021RemoteB | read-write | current | NID Series card Port 6 L2CP Mode 0180C2000021 0: Forward 1: Discard 2: Peer |
| 1.3.6.1.4.1.4756.20.502.20.1.1848 | ColumnnidL2CPPort6DMAC0180C2000022RemoteB | read-write | current | NID Series card Port 6 L2CP Mode 0180C2000022 0: Forward 1: Discard 2: Peer |
| 1.3.6.1.4.1.4756.20.502.20.1.1849 | ColumnnidL2CPPort6DMAC0180C2000023RemoteB | read-write | current | NID Series card Port 6 L2CP Mode 0180C2000023 0: Forward 1: Discard 2: Peer |
| 1.3.6.1.4.1.4756.20.502.20.1.1850 | ColumnnidL2CPPort6DMAC0180C2000024RemoteB | read-write | current | NID Series card Port 6 L2CP Mode 0180C2000024 0: Forward 1: Discard 2: Peer |
| 1.3.6.1.4.1.4756.20.502.20.1.1851 | ColumnnidL2CPPort6DMAC0180C2000025RemoteB | read-write | current | NID Series card Port 6 L2CP Mode 0180C2000025 0: Forward 1: Discard 2: Peer |
| 1.3.6.1.4.1.4756.20.502.20.1.1852 | ColumnnidL2CPPort6DMAC0180C2000026RemoteB | read-write | current | NID Series card Port 6 L2CP Mode 0180C2000026 0: Forward 1: Discard 2: Peer |
| 1.3.6.1.4.1.4756.20.502.20.1.1853 | ColumnnidL2CPPort6DMAC0180C2000027RemoteB | read-write | current | NID Series card Port 6 L2CP Mode 0180C2000027 0: Forward 1: Discard 2: Peer |
| 1.3.6.1.4.1.4756.20.502.20.1.1854 | ColumnnidL2CPPort6DMAC0180C2000028RemoteB | read-write | current | NID Series card Port 6 L2CP Mode 0180C2000028 0: Forward 1: Discard 2: Peer |
| 1.3.6.1.4.1.4756.20.502.20.1.1855 | ColumnnidL2CPPort6DMAC0180C2000029RemoteB | read-write | current | NID Series card Port 6 L2CP Mode 0180C2000029 0: Forward 1: Discard 2: Peer |
| 1.3.6.1.4.1.4756.20.502.20.1.1856 | ColumnnidL2CPPort6DMAC0180C200002ARemoteB | read-write | current | NID Series card Port 6 L2CP Mode 0180C200002A 0: Forward 1: Discard 2: Peer |
| 1.3.6.1.4.1.4756.20.502.20.1.1857 | ColumnnidL2CPPort6DMAC0180C200002BRemoteB | read-write | current | NID Series card Port 6 L2CP Mode 0180C200002B 0: Forward 1: Discard 2: Peer |
| 1.3.6.1.4.1.4756.20.502.20.1.1858 | ColumnnidL2CPPort6DMAC0180C200002CRemoteB | read-write | current | NID Series card Port 6 L2CP Mode 0180C200002C 0: Forward 1: Discard 2: Peer |
| 1.3.6.1.4.1.4756.20.502.20.1.1859 | ColumnnidL2CPPort6DMAC0180C200002DRemoteB | read-write | current | NID Series card Port 6 L2CP Mode 0180C200002D 0: Forward 1: Discard 2: Peer |
| 1.3.6.1.4.1.4756.20.502.20.1.1860 | ColumnnidL2CPPort6DMAC0180C200002ERemoteB | read-write | current | NID Series card Port 6 L2CP Mode 0180C200002E 0: Forward 1: Discard 2: Peer |
| 1.3.6.1.4.1.4756.20.502.20.1.1861 | ColumnnidL2CPPort6DMAC0180C200002FRemoteB | read-write | current | NID Series card Port 6 L2CP Mode 0180C200002F 0: Forward 1: Discard 1: Peer |
| 1.3.6.1.4.1.4756.20.502.20.1.1862 | ColumnnidL2CPPort7DMAC0180C2000000RemoteB | read-write | current | NID Series card Port 7 L2CP Mode 0180C2000000 0: Forward 1: Discard 2: Peer |
| 1.3.6.1.4.1.4756.20.502.20.1.1863 | ColumnnidL2CPPort7DMAC0180C2000001RemoteB | read-write | current | NID Series card Port 7 L2CP Mode 0180C2000001 0: Forward 1: Discard 2: Peer |
| 1.3.6.1.4.1.4756.20.502.20.1.1864 | ColumnnidL2CPPort7DMAC0180C2000002RemoteB | read-write | current | NID Series card Port 7 L2CP Mode 0180C2000002 0: Forward 1: Discard 2: Peer |
| 1.3.6.1.4.1.4756.20.502.20.1.1865 | ColumnnidL2CPPort7DMAC0180C2000003RemoteB | read-write | current | NID Series card Port 7 L2CP Mode 0180C2000003 0: Forward 1: Discard 2: Peer |
| 1.3.6.1.4.1.4756.20.502.20.1.1866 | ColumnnidL2CPPort7DMAC0180C2000004RemoteB | read-write | current | NID Series card Port 7 L2CP Mode 0180C2000004 0: Forward 1: Discard 2: Peer |
| 1.3.6.1.4.1.4756.20.502.20.1.1867 | ColumnnidL2CPPort7DMAC0180C2000005RemoteB | read-write | current | NID Series card Port 7 L2CP Mode 0180C2000005 0: Forward 1: Discard 2: Peer |
| 1.3.6.1.4.1.4756.20.502.20.1.1868 | ColumnnidL2CPPort7DMAC0180C2000006RemoteB | read-write | current | NID Series card Port 7 L2CP Mode 0180C2000006 0: Forward 1: Discard 2: Peer |
| 1.3.6.1.4.1.4756.20.502.20.1.1869 | ColumnnidL2CPPort7DMAC0180C2000007RemoteB | read-write | current | NID Series card Port 7 L2CP Mode 0180C2000007 0: Forward 1: Discard 2: Peer |
| 1.3.6.1.4.1.4756.20.502.20.1.1870 | ColumnnidL2CPPort7DMAC0180C2000008RemoteB | read-write | current | NID Series card Port 7 L2CP Mode 0180C2000008 0: Forward 1: Discard 2: Peer |
| 1.3.6.1.4.1.4756.20.502.20.1.1871 | ColumnnidL2CPPort7DMAC0180C2000009RemoteB | read-write | current | NID Series card Port 7 L2CP Mode 0180C2000009 0: Forward 1: Discard 2: Peer |
| 1.3.6.1.4.1.4756.20.502.20.1.1872 | ColumnnidL2CPPort7DMAC0180C200000ARemoteB | read-write | current | NID Series card Port 7 L2CP Mode 0180C200000A 0: Forward 1: Discard 2: Peer |
| 1.3.6.1.4.1.4756.20.502.20.1.1873 | ColumnnidL2CPPort7DMAC0180C200000BRemoteB | read-write | current | NID Series card Port 7 L2CP Mode 0180C200000B 0: Forward 1: Discard 2: Peer |
| 1.3.6.1.4.1.4756.20.502.20.1.1874 | ColumnnidL2CPPort7DMAC0180C200000CRemoteB | read-write | current | NID Series card Port 7 L2CP Mode 0180C200000C 0: Forward 1: Discard 2: Peer |
| 1.3.6.1.4.1.4756.20.502.20.1.1875 | ColumnnidL2CPPort7DMAC0180C200000DRemoteB | read-write | current | NID Series card Port 7 L2CP Mode 0180C200000D 0: Forward 1: Discard 2: Peer |
| 1.3.6.1.4.1.4756.20.502.20.1.1876 | ColumnnidL2CPPort7DMAC0180C200000ERemoteB | read-write | current | NID Series card Port 7 L2CP Mode 0180C200000E 0: Forward 1: Discard 2: Peer |
| 1.3.6.1.4.1.4756.20.502.20.1.1877 | ColumnnidL2CPPort7DMAC0180C200000FRemoteB | read-write | current | NID Series card Port 7 L2CP Mode 0180C200000F 0: Forward 1: Discard 2: Peer |
| 1.3.6.1.4.1.4756.20.502.20.1.1878 | ColumnnidL2CPPort7DMAC0180C2000010RemoteB | read-write | current | NID Series card Port 7 L2CP Mode 0180C2000010 0: Forward 1: Discard 2: Peer |
| 1.3.6.1.4.1.4756.20.502.20.1.1879 | ColumnnidL2CPPort7DMAC0180C2000020RemoteB | read-write | current | NID Series card Port 7 L2CP Mode 0180C2000020 0: Forward 1: Discard 2: Peer |
| 1.3.6.1.4.1.4756.20.502.20.1.1880 | ColumnnidL2CPPort7DMAC0180C2000021RemoteB | read-write | current | NID Series card Port 7 L2CP Mode 0180C2000021 0: Forward 1: Discard 2: Peer |
| 1.3.6.1.4.1.4756.20.502.20.1.1881 | ColumnnidL2CPPort7DMAC0180C2000022RemoteB | read-write | current | NID Series card Port 7 L2CP Mode 0180C2000022 0: Forward 1: Discard 2: Peer |
| 1.3.6.1.4.1.4756.20.502.20.1.1882 | ColumnnidL2CPPort7DMAC0180C2000023RemoteB | read-write | current | NID Series card Port 7 L2CP Mode 0180C2000023 0: Forward 1: Discard 2: Peer |
| 1.3.6.1.4.1.4756.20.502.20.1.1883 | ColumnnidL2CPPort7DMAC0180C2000024RemoteB | read-write | current | NID Series card Port 7 L2CP Mode 0180C2000024 0: Forward 1: Discard 2: Peer |
| 1.3.6.1.4.1.4756.20.502.20.1.1884 | ColumnnidL2CPPort7DMAC0180C2000025RemoteB | read-write | current | NID Series card Port 7 L2CP Mode 0180C2000025 0: Forward 1: Discard 2: Peer |
| 1.3.6.1.4.1.4756.20.502.20.1.1885 | ColumnnidL2CPPort7DMAC0180C2000026RemoteB | read-write | current | NID Series card Port 7 L2CP Mode 0180C2000026 0: Forward 1: Discard 2: Peer |
| 1.3.6.1.4.1.4756.20.502.20.1.1886 | ColumnnidL2CPPort7DMAC0180C2000027RemoteB | read-write | current | NID Series card Port 7 L2CP Mode 0180C2000027 0: Forward 1: Discard 2: Peer |
| 1.3.6.1.4.1.4756.20.502.20.1.1887 | ColumnnidL2CPPort7DMAC0180C2000028RemoteB | read-write | current | NID Series card Port 7 L2CP Mode 0180C2000028 0: Forward 1: Discard 2: Peer |
| 1.3.6.1.4.1.4756.20.502.20.1.1888 | ColumnnidL2CPPort7DMAC0180C2000029RemoteB | read-write | current | NID Series card Port 7 L2CP Mode 0180C2000029 0: Forward 1: Discard 2: Peer |
| 1.3.6.1.4.1.4756.20.502.20.1.1889 | ColumnnidL2CPPort7DMAC0180C200002ARemoteB | read-write | current | NID Series card Port 7 L2CP Mode 0180C200002A 0: Forward 1: Discard 2: Peer |
| 1.3.6.1.4.1.4756.20.502.20.1.1890 | ColumnnidL2CPPort7DMAC0180C200002BRemoteB | read-write | current | NID Series card Port 7 L2CP Mode 0180C200002B 0: Forward 1: Discard 2: Peer |
| 1.3.6.1.4.1.4756.20.502.20.1.1891 | ColumnnidL2CPPort7DMAC0180C200002CRemoteB | read-write | current | NID Series card Port 7 L2CP Mode 0180C200002C 0: Forward 1: Discard 2: Peer |
| 1.3.6.1.4.1.4756.20.502.20.1.1892 | ColumnnidL2CPPort7DMAC0180C200002DRemoteB | read-write | current | NID Series card Port 7 L2CP Mode 0180C200002D 0: Forward 1: Discard 2: Peer |
| 1.3.6.1.4.1.4756.20.502.20.1.1893 | ColumnnidL2CPPort7DMAC0180C200002ERemoteB | read-write | current | NID Series card Port 7 L2CP Mode 0180C200002E 0: Forward 1: Discard 2: Peer |
| 1.3.6.1.4.1.4756.20.502.20.1.1894 | ColumnnidL2CPPort7DMAC0180C200002FRemoteB | read-write | current | NID Series card Port 7 L2CP Mode 0180C200002F 0: Forward 1: Discard 1: Peer |
| 1.3.6.1.4.1.4756.20.502.20.1.1895 | ColumnnidL2CPPort8DMAC0180C2000000RemoteB | read-write | current | NID Series card Port 8 L2CP Mode 0180C2000000 0: Forward 1: Discard 2: Peer |
| 1.3.6.1.4.1.4756.20.502.20.1.1896 | ColumnnidL2CPPort8DMAC0180C2000001RemoteB | read-write | current | NID Series card Port 8 L2CP Mode 0180C2000001 0: Forward 1: Discard 2: Peer |
| 1.3.6.1.4.1.4756.20.502.20.1.1897 | ColumnnidL2CPPort8DMAC0180C2000002RemoteB | read-write | current | NID Series card Port 8 L2CP Mode 0180C2000002 0: Forward 1: Discard 2: Peer |
| 1.3.6.1.4.1.4756.20.502.20.1.1898 | ColumnnidL2CPPort8DMAC0180C2000003RemoteB | read-write | current | NID Series card Port 8 L2CP Mode 0180C2000003 0: Forward 1: Discard 2: Peer |
| 1.3.6.1.4.1.4756.20.502.20.1.1899 | ColumnnidL2CPPort8DMAC0180C2000004RemoteB | read-write | current | NID Series card Port 8 L2CP Mode 0180C2000004 0: Forward 1: Discard 2: Peer |
| 1.3.6.1.4.1.4756.20.502.20.1.1900 | ColumnnidL2CPPort8DMAC0180C2000005RemoteB | read-write | current | NID Series card Port 8 L2CP Mode 0180C2000005 0: Forward 1: Discard 2: Peer |
| 1.3.6.1.4.1.4756.20.502.20.1.1901 | ColumnnidL2CPPort8DMAC0180C2000006RemoteB | read-write | current | NID Series card Port 8 L2CP Mode 0180C2000006 0: Forward 1: Discard 2: Peer |
| 1.3.6.1.4.1.4756.20.502.20.1.1902 | ColumnnidL2CPPort8DMAC0180C2000007RemoteB | read-write | current | NID Series card Port 8 L2CP Mode 0180C2000007 0: Forward 1: Discard 2: Peer |
| 1.3.6.1.4.1.4756.20.502.20.1.1903 | ColumnnidL2CPPort8DMAC0180C2000008RemoteB | read-write | current | NID Series card Port 8 L2CP Mode 0180C2000008 0: Forward 1: Discard 2: Peer |
| 1.3.6.1.4.1.4756.20.502.20.1.1904 | ColumnnidL2CPPort8DMAC0180C2000009RemoteB | read-write | current | NID Series card Port 8 L2CP Mode 0180C2000009 0: Forward 1: Discard 2: Peer |
| 1.3.6.1.4.1.4756.20.502.20.1.1905 | ColumnnidL2CPPort8DMAC0180C200000ARemoteB | read-write | current | NID Series card Port 8 L2CP Mode 0180C200000A 0: Forward 1: Discard 2: Peer |
| 1.3.6.1.4.1.4756.20.502.20.1.1906 | ColumnnidL2CPPort8DMAC0180C200000BRemoteB | read-write | current | NID Series card Port 8 L2CP Mode 0180C200000B 0: Forward 1: Discard 2: Peer |
| 1.3.6.1.4.1.4756.20.502.20.1.1907 | ColumnnidL2CPPort8DMAC0180C200000CRemoteB | read-write | current | NID Series card Port 8 L2CP Mode 0180C200000C 0: Forward 1: Discard 2: Peer |
| 1.3.6.1.4.1.4756.20.502.20.1.1908 | ColumnnidL2CPPort8DMAC0180C200000DRemoteB | read-write | current | NID Series card Port 8 L2CP Mode 0180C200000D 0: Forward 1: Discard 2: Peer |
| 1.3.6.1.4.1.4756.20.502.20.1.1909 | ColumnnidL2CPPort8DMAC0180C200000ERemoteB | read-write | current | NID Series card Port 8 L2CP Mode 0180C200000E 0: Forward 1: Discard 2: Peer |
| 1.3.6.1.4.1.4756.20.502.20.1.1910 | ColumnnidL2CPPort8DMAC0180C200000FRemoteB | read-write | current | NID Series card Port 8 L2CP Mode 0180C200000F 0: Forward 1: Discard 2: Peer |
| 1.3.6.1.4.1.4756.20.502.20.1.1911 | ColumnnidL2CPPort8DMAC0180C2000010RemoteB | read-write | current | NID Series card Port 8 L2CP Mode 0180C2000010 0: Forward 1: Discard 2: Peer |
| 1.3.6.1.4.1.4756.20.502.20.1.1912 | ColumnnidL2CPPort8DMAC0180C2000020RemoteB | read-write | current | NID Series card Port 8 L2CP Mode 0180C2000020 0: Forward 1: Discard 2: Peer |
| 1.3.6.1.4.1.4756.20.502.20.1.1913 | ColumnnidL2CPPort8DMAC0180C2000021RemoteB | read-write | current | NID Series card Port 8 L2CP Mode 0180C2000021 0: Forward 1: Discard 2: Peer |
| 1.3.6.1.4.1.4756.20.502.20.1.1914 | ColumnnidL2CPPort8DMAC0180C2000022RemoteB | read-write | current | NID Series card Port 8 L2CP Mode 0180C2000022 0: Forward 1: Discard 2: Peer |
| 1.3.6.1.4.1.4756.20.502.20.1.1915 | ColumnnidL2CPPort8DMAC0180C2000023RemoteB | read-write | current | NID Series card Port 8 L2CP Mode 0180C2000023 0: Forward 1: Discard 2: Peer |
| 1.3.6.1.4.1.4756.20.502.20.1.1916 | ColumnnidL2CPPort8DMAC0180C2000024RemoteB | read-write | current | NID Series card Port 8 L2CP Mode 0180C2000024 0: Forward 1: Discard 2: Peer |
| 1.3.6.1.4.1.4756.20.502.20.1.1917 | ColumnnidL2CPPort8DMAC0180C2000025RemoteB | read-write | current | NID Series card Port 8 L2CP Mode 0180C2000025 0: Forward 1: Discard 2: Peer |
| 1.3.6.1.4.1.4756.20.502.20.1.1918 | ColumnnidL2CPPort8DMAC0180C2000026RemoteB | read-write | current | NID Series card Port 8 L2CP Mode 0180C2000026 0: Forward 1: Discard 2: Peer |
| 1.3.6.1.4.1.4756.20.502.20.1.1919 | ColumnnidL2CPPort8DMAC0180C2000027RemoteB | read-write | current | NID Series card Port 8 L2CP Mode 0180C2000027 0: Forward 1: Discard 2: Peer |
| 1.3.6.1.4.1.4756.20.502.20.1.1920 | ColumnnidL2CPPort8DMAC0180C2000028RemoteB | read-write | current | NID Series card Port 8 L2CP Mode 0180C2000028 0: Forward 1: Discard 2: Peer |
| 1.3.6.1.4.1.4756.20.502.20.1.1921 | ColumnnidL2CPPort8DMAC0180C2000029RemoteB | read-write | current | NID Series card Port 8 L2CP Mode 0180C2000029 0: Forward 1: Discard 2: Peer |
| 1.3.6.1.4.1.4756.20.502.20.1.1922 | ColumnnidL2CPPort8DMAC0180C200002ARemoteB | read-write | current | NID Series card Port 8 L2CP Mode 0180C200002A 0: Forward 1: Discard 2: Peer |
| 1.3.6.1.4.1.4756.20.502.20.1.1923 | ColumnnidL2CPPort8DMAC0180C200002BRemoteB | read-write | current | NID Series card Port 8 L2CP Mode 0180C200002B 0: Forward 1: Discard 2: Peer |
| 1.3.6.1.4.1.4756.20.502.20.1.1924 | ColumnnidL2CPPort8DMAC0180C200002CRemoteB | read-write | current | NID Series card Port 8 L2CP Mode 0180C200002C 0: Forward 1: Discard 2: Peer |
| 1.3.6.1.4.1.4756.20.502.20.1.1925 | ColumnnidL2CPPort8DMAC0180C200002DRemoteB | read-write | current | NID Series card Port 8 L2CP Mode 0180C200002D 0: Forward 1: Discard 2: Peer |
| 1.3.6.1.4.1.4756.20.502.20.1.1926 | ColumnnidL2CPPort8DMAC0180C200002ERemoteB | read-write | current | NID Series card Port 8 L2CP Mode 0180C200002E 0: Forward 1: Discard 2: Peer |
| 1.3.6.1.4.1.4756.20.502.20.1.1927 | ColumnnidL2CPPort8DMAC0180C200002FRemoteB | read-write | current | NID Series card Port 8 L2CP Mode 0180C200002F 0: Forward 1: Discard 1: Peer |
| 1.3.6.1.4.1.4756.20.502.20.1.1928 | ColumnnidFx1DDRemoteB | read-only | current | NID Series card fiber port Digital Diagnostic function: 0:No 1:Yes |
| 1.3.6.1.4.1.4756.20.502.20.1.1929 | ColumnnidFx1DDVendorRemoteB | read-only | current | NID Series card fiber port D/D information: Vendor name |
| 1.3.6.1.4.1.4756.20.502.20.1.1930 | ColumnnidFx1DDPartNoRemoteB | read-only | current | NID Series card fiber port D/D information: Vendor part number |
| 1.3.6.1.4.1.4756.20.502.20.1.1931 | ColumnnidFx1DDFiberTypeRemoteB | read-only | current | NID Series card fiber port D/D information: Fiber Type |
| 1.3.6.1.4.1.4756.20.502.20.1.1932 | ColumnnidFx1DDWaveLenRemoteB | read-only | current | NID Series card fiber port D/D information: Wave length |
| 1.3.6.1.4.1.4756.20.502.20.1.1933 | ColumnnidFx1DDWaveLen2RemoteB | read-only | current | NID Series card fiber port D/D information: Wave length 2 |
| 1.3.6.1.4.1.4756.20.502.20.1.1934 | ColumnnidFx1DDLinkLenRemoteB | read-only | current | NID Series card fiber port D/D information: Link length |
| 1.3.6.1.4.1.4756.20.502.20.1.1935 | ColumnnidFx1DDLenUnitRemoteB | read-only | current | NID Series card fiber port D/D information: Length Unit |
| 1.3.6.1.4.1.4756.20.502.20.1.1936 | ColumnnidFx1DDStatusRemoteB | read-only | current | NID Series card fiber port D/D information: Status Support |
| 1.3.6.1.4.1.4756.20.502.20.1.1937 | ColumnnidFx1DDRxSensRemoteB | read-only | current | NID Series card fiber port D/D information: Rx Sensitivity |
| 1.3.6.1.4.1.4756.20.502.20.1.1938 | ColumnnidFx1DDTxPWRRemoteB | read-only | current | NID Series card fiber port D/D information: Tx power |
| 1.3.6.1.4.1.4756.20.502.20.1.1939 | ColumnnidFx1DDRxPWRRemoteB | read-only | current | NID Series card fiber port D/D information: Rx power |
| 1.3.6.1.4.1.4756.20.502.20.1.1940 | ColumnnidFx1DDTempRemoteB | read-only | current | NID Series card fiber port D/D information: Temperature in degree C |
| 1.3.6.1.4.1.4756.20.502.20.1.1941 | ColumnnidFx1DDPWRMarginRemoteB | read-only | current | NID Series card fiber port D/D information: Power margin |
| 1.3.6.1.4.1.4756.20.502.20.1.1942 | ColumnnidFx1DDPWRLossRemoteB | read-only | current | NID Series card fiber port D/D information: Power loss |
| 1.3.6.1.4.1.4756.20.502.20.1.1943 | ColumnnidFx2DDRemoteB | read-only | current | NID Series card fiber2 Digital Diagnostic function: 0:NO 1:Yes |
| 1.3.6.1.4.1.4756.20.502.20.1.1944 | ColumnnidFx2DDVendorRemoteB | read-only | current | NID Series card fiber2 D/D information: Vendor name |
| 1.3.6.1.4.1.4756.20.502.20.1.1945 | ColumnnidFx2DDPartNoRemoteB | read-only | current | NID Series card fiber2 D/D information: Vendor part number |
| 1.3.6.1.4.1.4756.20.502.20.1.1946 | ColumnnidFx2DDFiberTypeRemoteB | read-only | current | NID Series card fiber2 D/D information: Fiber Type |
| 1.3.6.1.4.1.4756.20.502.20.1.1947 | ColumnnidFx2DDWaveLenRemoteB | read-only | current | NID Series card fiber2 D/D information: Wave length 1 |
| 1.3.6.1.4.1.4756.20.502.20.1.1948 | ColumnnidFx2DDWaveLen2RemoteB | read-only | current | NID Series card fiber2 D/D information: Wave length 2 |
| 1.3.6.1.4.1.4756.20.502.20.1.1949 | ColumnnidFx2DDLinkLenRemoteB | read-only | current | NID Series card fiber2 D/D information: Link length |
| 1.3.6.1.4.1.4756.20.502.20.1.1950 | ColumnnidFx2DDLenUnitRemoteB | read-only | current | NID Series card fiber2 D/D information: Length Unit |
| 1.3.6.1.4.1.4756.20.502.20.1.1951 | ColumnnidFx2DDStatusRemoteB | read-only | current | NID Series card fiber2 D/D information: Status Support |
| 1.3.6.1.4.1.4756.20.502.20.1.1952 | ColumnnidFx2DDRxSensRemoteB | read-only | current | NID Series card fiber2 D/D information: Rx Sensitivity |
| 1.3.6.1.4.1.4756.20.502.20.1.1953 | ColumnnidFx2DDTxPWRRemoteB | read-only | current | NID Series card fiber2 D/D information: Tx power |
| 1.3.6.1.4.1.4756.20.502.20.1.1954 | ColumnnidFx2DDRxPWRRemoteB | read-only | current | NID Series card fiber2 D/D information: Rx power |
| 1.3.6.1.4.1.4756.20.502.20.1.1955 | ColumnnidFx2DDTempRemoteB | read-only | current | NID Series card fiber2 D/D information: Temperature in degree C |
| 1.3.6.1.4.1.4756.20.502.20.1.1956 | ColumnnidFx2DDPWRMarginRemoteB | read-only | current | NID Series card fiber2 D/D information: Power margin |
| 1.3.6.1.4.1.4756.20.502.20.1.1957 | ColumnnidFx2DDPWRLossRemoteB | read-only | current | NID Series card fiber2 D/D information: Power loss |
| 1.3.6.1.4.1.4756.20.502.20.1.1958 | ColumnnidFx3DDRemoteB | read-only | current | NID Series card fiber3 Digital Diagnostic function: 0:NO 1:Yes |
| 1.3.6.1.4.1.4756.20.502.20.1.1959 | ColumnnidFx3DDVendorRemoteB | read-only | current | NID Series card fiber3 D/D information: Vendor name |
| 1.3.6.1.4.1.4756.20.502.20.1.1960 | ColumnnidFx3DDPartNoRemoteB | read-only | current | NID Series card fiber32 D/D information: Vendor part number |
| 1.3.6.1.4.1.4756.20.502.20.1.1961 | ColumnnidFx3DDFiberTypeRemoteB | read-only | current | NID Series card fiber3 D/D information: Fiber Type |
| 1.3.6.1.4.1.4756.20.502.20.1.1962 | ColumnnidFx3DDWaveLenRemoteB | read-only | current | NID Series card fiber3 D/D information: Wave length 1 |
| 1.3.6.1.4.1.4756.20.502.20.1.1963 | ColumnnidFx3DDWaveLen2RemoteB | read-only | current | NID Series card fiber3 D/D information: Wave length 2 |
| 1.3.6.1.4.1.4756.20.502.20.1.1964 | ColumnnidFx3DDLinkLenRemoteB | read-only | current | NID Series card fiber3 D/D information: Link length |
| 1.3.6.1.4.1.4756.20.502.20.1.1965 | ColumnnidFx3DDLenUnitRemoteB | read-only | current | NID Series card fiber3 D/D information: Length Unit |
| 1.3.6.1.4.1.4756.20.502.20.1.1966 | ColumnnidFx3DDStatusRemoteB | read-only | current | NID Series card fiber3 D/D information: Status Support |
| 1.3.6.1.4.1.4756.20.502.20.1.1967 | ColumnnidFx3DDRxSensRemoteB | read-only | current | NID Series card fiber3 D/D information: Rx Sensitivity |
| 1.3.6.1.4.1.4756.20.502.20.1.1968 | ColumnnidFx3DDTxPWRRemoteB | read-only | current | NID Series card fiber3 D/D information: Tx power |
| 1.3.6.1.4.1.4756.20.502.20.1.1969 | ColumnnidFx3DDRxPWRRemoteB | read-only | current | NID Series card fiber3 D/D information: Rx power |
| 1.3.6.1.4.1.4756.20.502.20.1.1970 | ColumnnidFx3DDTempRemoteB | read-only | current | NID Series card fiber3 D/D information: Temperature in degree C |
| 1.3.6.1.4.1.4756.20.502.20.1.1971 | ColumnnidFx3DDPWRMarginRemoteB | read-only | current | NID Series card fiber3 D/D information: Power margin |
| 1.3.6.1.4.1.4756.20.502.20.1.1972 | ColumnnidFx3DDPWRLossRemoteB | read-only | current | NID Series card fiber3 D/D information: Power loss |
| 1.3.6.1.4.1.4756.20.502.20.1.1973 | ColumnnidFx4DDRemoteB | read-only | current | NID Series card fiber4 Digital Diagnostic function: 0:NO 1:Yes |
| 1.3.6.1.4.1.4756.20.502.20.1.1974 | ColumnnidFx4DDVendorRemoteB | read-only | current | NID Series card fiber4 D/D information: Vendor name |
| 1.3.6.1.4.1.4756.20.502.20.1.1975 | ColumnnidFx4DDPartNoRemoteB | read-only | current | NID Series card fiber4 D/D information: Vendor part number |
| 1.3.6.1.4.1.4756.20.502.20.1.1976 | ColumnnidFx4DDFiberTypeRemoteB | read-only | current | NID Series card fiber4 D/D information: Fiber Type |
| 1.3.6.1.4.1.4756.20.502.20.1.1977 | ColumnnidFx4DDWaveLenRemoteB | read-only | current | NID Series card fiber4 D/D information: Wave length 1 |
| 1.3.6.1.4.1.4756.20.502.20.1.1978 | ColumnnidFx4DDWaveLen2RemoteB | read-only | current | NID Series card fiber4 D/D information: Wave length 2 |
| 1.3.6.1.4.1.4756.20.502.20.1.1979 | ColumnnidFx4DDLinkLenRemoteB | read-only | current | NID Series card fiber4 D/D information: Link length |
| 1.3.6.1.4.1.4756.20.502.20.1.1980 | ColumnnidFx4DDLenUnitRemoteB | read-only | current | NID Series card fiber4 D/D information: Length Unit |
| 1.3.6.1.4.1.4756.20.502.20.1.1981 | ColumnnidFx4DDStatusRemoteB | read-only | current | NID Series card fiber4 D/D information: Status Support |
| 1.3.6.1.4.1.4756.20.502.20.1.1982 | ColumnnidFx4DDRxSensRemoteB | read-only | current | NID Series card fiber4 D/D information: Rx Sensitivity |
| 1.3.6.1.4.1.4756.20.502.20.1.1983 | ColumnnidFx4DDTxPWRRemoteB | read-only | current | NID Series card fiber4 D/D information: Tx power |
| 1.3.6.1.4.1.4756.20.502.20.1.1984 | ColumnnidFx4DDRxPWRRemoteB | read-only | current | NID Series card fiber4 D/D information: Rx power |
| 1.3.6.1.4.1.4756.20.502.20.1.1985 | ColumnnidFx4DDTempRemoteB | read-only | current | NID Series card fiber4 D/D information: Temperature in degree C |
| 1.3.6.1.4.1.4756.20.502.20.1.1986 | ColumnnidFx4DDPWRMarginRemoteB | read-only | current | NID Series card fiber4 D/D information: Power margin |
| 1.3.6.1.4.1.4756.20.502.20.1.1987 | ColumnnidFx4DDPWRLossRemoteB | read-only | current | NID Series card fiber4 D/D information: Power loss |
| 1.3.6.1.4.1.4756.20.502.20.1.1988 | ColumnnidDeviceActiveRemoteB | read-write | current | NID Series card u-Ring device active 0: Disable 1: Enable |
| 1.3.6.1.4.1.4756.20.502.20.1.1989 | ColumnnidSaveStartupCongRemoteB | read-write | current | NID Series card save start-up config 0: OFF 1: Action |
| 1.3.6.1.4.1.4756.20.502.20.1.1990 | ColumnnidPortResetRemoteB | read-write | current | NID Series card port reset 0: OFF 1: Action |
| 1.3.6.1.4.1.4756.20.502.20.1.1991 | ColumnnidSetDefaultRemoteB | read-write | current | NID Series card set to default config 0: OFF 1: Action |
| 1.3.6.1.4.1.4756.20.502.20.1.1992 | ColumnnidSetDefault2RemoteB | read-write | current | NID Series card set to default config (Without OAM) 0: OFF 1: Action |
| 1.3.6.1.4.1.4756.20.502.20.1.1993 | ColumnnidClearPortCounterRemoteB | read-write | current | NID Series card clear port counter: 0: Off 1: Action |
| 1.3.6.1.4.1.4756.20.502.20.1.1994 | ColumnnidClearOAMCounterRemoteB | read-write | current | NID Series card Clear OAM Counter: 0: Off 1: Action |
| 1.3.6.1.4.1.4756.20.502.20.1.1995 | ColumnnidSTPStatisticsPortClearCounterRemoteB | read-write | current | NID Series card STP Port Statistics: Clear Counters 0: OFff 1: Action |
| 1.3.6.1.4.1.4756.20.502.20.1.1996 | ColumnnidAlarmRemoteB | read-only | current | NID Series card Alarm led status: 0: Off 1: On |
| 1.3.6.1.4.1.4756.20.502.20.1.1997 | ColumnnidTest1RemoteB | read-only | current | NID Series card Test1 led status: 0: Off 1: On |
| 1.3.6.1.4.1.4756.20.502.20.1.1998 | ColumnnidTest2RemoteB | read-only | current | NID Series card Test2 led status: 0: Off 1: On |
| 1.3.6.1.4.1.4756.20.600 | Nodeoab15Cards | |||
| 1.3.6.1.4.1.4756.20.600.20 | Tableoab15Table | not-accessible | current | A list of local OAB15 card entries. The number of entries is oab15-No-L. |
| 1.3.6.1.4.1.4756.20.600.20.1 | Rowoab15Entry | not-accessible | current | An entry containing management information applicable to a particular local FRM220 OAB15 card. |
| 1.3.6.1.4.1.4756.20.600.20.1.1 | Columnoab15ChassisIndex | read-only | current | A unique value for each local card. It is the chassis location number. |
| 1.3.6.1.4.1.4756.20.600.20.1.2 | Columnoab15SlotIndex | read-only | current | A unique value for each local card. It is the slot location number. |
| 1.3.6.1.4.1.4756.20.600.20.1.3 | Columnoab15CardHWVer | read-only | current | Local FRM220 OAB15 card hardware version x.xxx |
| 1.3.6.1.4.1.4756.20.600.20.1.4 | Columnoab15CardFWVer | read-only | current | Local FRM220 OAB15 card firmware version x.xxx |
| 1.3.6.1.4.1.4756.20.600.20.1.5 | Columnoab15CardCPLDVer | read-only | current | Local FRM220 OAB15 card CPLD version x.xxx |
| 1.3.6.1.4.1.4756.20.600.20.1.6 | Columnoab15CardFPGAVer | read-only | current | Local FRM220 OAB15 card FPGA version x.xxx |
| 1.3.6.1.4.1.4756.20.600.20.1.7 | Columnoab15PumpCurrentStatus | read-only | current | Local FRM220 OAB15 card pump current status (Unit is mA) |
| 1.3.6.1.4.1.4756.20.600.20.1.8 | Columnoab15OutputPowerStatus | read-only | current | Local FRM220 OAB15 card output power status (Unit is dBm) |
| 1.3.6.1.4.1.4756.20.600.20.1.9 | Columnoab15PumpPowerStatus | read-only | current | Local FRM220 OAB15 card pump power status (Unit is mW) |
| 1.3.6.1.4.1.4756.20.600.20.1.10 | Columnoab15TemperatureStatus | read-only | current | Local FRM220 OAB15 card temperature Status (Unit is degree C) |
| 1.3.6.1.4.1.4756.20.600.20.1.11 | Columnoab15OutputPower | read-write | current | Local FRM220 OAB15 card set output power(Unit is dBm) Input range is from 10 to 15 |
| 1.3.6.1.4.1.4756.20.600.20.1.12 | Columnoab15DeviceActive | read-write | current | Local FRM220 OAB15 card device active: 0:Disable 1:Enable |
| 1.3.6.1.4.1.4756.20.600.20.1.13 | Columnoab15DeviceReset | read-write | current | Local FRM220 OAB15 card device reset: 0:Off 1:Action |
| 1.3.6.1.4.1.4756.20.600.20.1.14 | Columnoab15SetDefault | read-only | current | Local FRM220 OAB15 set to default: 0:Off 1:Action |
| 1.3.6.1.4.1.4756.20.600.20.1.15 | Columnoab15LosAssert110GSXXSlot | read-write | current | Local FRM220 OAB15 Los Assert1 10G-SXX Slot No.: Please enter the slot number '2'~'20' or 'none' |
| 1.3.6.1.4.1.4756.20.600.20.1.16 | Columnoab15LosAssert110GSXXPropagation | read-write | current | Local FRM220 OAB15 Assert1 10G-SXX LOS Propagation: 0:line 1:Primary & Second |
| 1.3.6.1.4.1.4756.20.600.20.1.17 | Columnoab15LosAssert210GSXXSlot | read-write | current | Local FRM220 OAB15 Los Assert2 10G-SXX Slot No.: Please enter the slot number '2'~'20' or 'none' |
| 1.3.6.1.4.1.4756.20.600.20.1.18 | Columnoab15LosAssert210GSXXPropagation | read-write | current | Local FRM220 OAB15 Assert2 10G-SXX LOS Propagation: 0:line 1:Primary & Second |
| 1.3.6.1.4.1.4756.20.600.20.1.19 | Columnoab15LosAssert310GSXXSlot | read-write | current | Local FRM220 OAB15 Los Assert3 10G-SXX Slot No.: Please enter the slot number '2'~'20' or 'none' |
| 1.3.6.1.4.1.4756.20.600.20.1.20 | Columnoab15LosAssert310GSXXPropagation | read-write | current | Local FRM220 OAB15 Assert3 10G-SXX LOS Propagation: 0:line 1:Primary & Second |
| 1.3.6.1.4.1.4756.20.600.20.1.21 | Columnoab15LosAssert410GSXXSlot | read-write | current | Local FRM220 OAB15 Los Assert4 10G-SXX Slot No.: Please enter the slot number '2'~'20' or 'none' |
| 1.3.6.1.4.1.4756.20.600.20.1.22 | Columnoab15LosAssert410GSXXPropagation | read-write | current | Local FRM220 OAB15 Assert4 10G-SXX LOS Propagation: 0:line 1:Primary & Second |
| 1.3.6.1.4.1.4756.20.600.20.1.23 | Columnoab15Alarm | read-only | current | Local FRM220 OAB15 Alarm: 0:Pump drive current is over limit. 1:Output power is less than setting output power(< 1dB) 2:Output power is over the setting output… |
| 1.3.6.1.4.1.4756.20.600.20.1.24 | Columnoab15Mgmt | read-only | current | Local FRM220 OAB15 Module Condition Active: 0:Inactive 1:Active |
| 1.3.6.1.4.1.4756.20.610 | Nodeeoe1GSLocalCards | |||
| 1.3.6.1.4.1.4756.20.610.20 | Tableeoe1GSLocalTable | not-accessible | current | A list of local FRM220-EOE1/GS card entries. The number of entries is eoe1GS-No-L. |
| 1.3.6.1.4.1.4756.20.610.20.1 | Roweoe1GSLocalEntry | not-accessible | current | An entry containing management information applicable to a particular local FRM220-Eoe1GS series card. |
| 1.3.6.1.4.1.4756.20.610.20.1.1 | Columneoe1GSChassisIndexLocal | read-only | current | A unique value for each card. It starts from 0 to 9 contiguously. |
| 1.3.6.1.4.1.4756.20.610.20.1.2 | Columneoe1GSSlotIndexLocal | read-only | current | A unique value for each card. It starts from 1 to 20 contiguously. |
| 1.3.6.1.4.1.4756.20.610.20.1.3 | Columneoe1GSCardHWVerLocal | read-only | current | Eoe1/GS card hardware version x.xxx |
| 1.3.6.1.4.1.4756.20.610.20.1.4 | Columneoe1GSCardFWVerLocal | read-only | current | Eoe1/GS card firmware version x.xxx |
| 1.3.6.1.4.1.4756.20.610.20.1.5 | Columneoe1GSCardCPLDVerLocal | read-only | current | Eoe1/GS card CPLD version x.xxx |
| 1.3.6.1.4.1.4756.20.610.20.1.6 | Columneoe1GSCardFPGAVerLocal | read-only | current | Eoe1/GS card FPGA version x.xxx |
| 1.3.6.1.4.1.4756.20.610.20.1.7 | Columneoe1GSPortResetLocal | read-write | current | Eoe1/GS card system status: 0:Off 1:Trigger |
| 1.3.6.1.4.1.4756.20.610.20.1.8 | Columneoe1GSSetToDefaultLocal | read-write | current | Eoe1/GS card port set to default: 0:Off 1:Trigger |
| 1.3.6.1.4.1.4756.20.610.20.1.9 | Columneoe1GSLOSLocal | read-only | current | Eoe1/GS card LOS status: 0:No 1:Yes |
| 1.3.6.1.4.1.4756.20.610.20.1.10 | Columneoe1GSLOFLocal | read-only | current | Eoe1/GS card LOF status: 0:No 1:Yes |
| 1.3.6.1.4.1.4756.20.610.20.1.11 | Columneoe1GSAISLocal | read-only | current | Eoe1/GS card AIS status: 0:No 1:Yes |
| 1.3.6.1.4.1.4756.20.610.20.1.12 | Columneoe1GSRAILocal | read-only | current | Eoe1/GS card RAI status: 0:No 1:Yes |
| 1.3.6.1.4.1.4756.20.610.20.1.13 | Columneoe1GSCRCLocal | read-only | current | Eoe1/GS card CRC status: 0:No 1:Yes |
| 1.3.6.1.4.1.4756.20.610.20.1.14 | Columneoe1GSBPVLocal | read-only | current | Eoe1/GS card BPV status: 0:No 1:Yes |
| 1.3.6.1.4.1.4756.20.610.20.1.15 | Columneoe1GSLoopStatusLocal | read-only | current | Eoe1/GS card Loop status: 0:No 1:Yes |
| 1.3.6.1.4.1.4756.20.610.20.1.16 | Columneoe1GSE1ModeLocal | read-write | current | Eoe1/GS card E1 mode: 0:Unframe 1:Frame |
| 1.3.6.1.4.1.4756.20.610.20.1.17 | Columneoe1GSE1LoopBackLocal | read-write | current | Eoe1/GS card E1 loopback : 0:OFF 1:LLB 2:RLB |
| 1.3.6.1.4.1.4756.20.610.20.1.18 | Columneoe1GSE1LoopDetectionLocal | read-write | current | Eoe1/GS card E1 loop detection: 0:Disable 1:Enalbe |
| 1.3.6.1.4.1.4756.20.610.20.1.19 | Columneoe1GSE1HDLCLocal | read-write | current | Eoe1/GS Series card E1 HDLC: 0:Inverse 1:Consisten |
| 1.3.6.1.4.1.4756.20.610.20.1.20 | Columneoe1GSTimingSourceLocal | read-write | current | Eoe1/GS card timing source: 0:Recovery from E1 receive 1:Internal oscillator |
| 1.3.6.1.4.1.4756.20.610.20.1.21 | Columneoe1GSFailOverLocal | read-write | current | Eoe1/GS card failover: 0:Disalbe 1:Enable |
| 1.3.6.1.4.1.4756.20.610.20.1.22 | Columneoe1GSEncapsulationLocal | read-write | current | Eoe1/GS card encapsulation: 0:GFP 1:HDLC |
| 1.3.6.1.4.1.4756.20.610.20.1.23 | Columneoe1GSNetManageLocal | read-write | current | Eoe1/GS Series card net manage: 0:Disable 1:Enable |
| 1.3.6.1.4.1.4756.20.610.20.1.24 | Columneoe1GSFxModelLocal | read-only | current | Eoe1/GS card SFP model: 0:No Model 1:OnLine |
| 1.3.6.1.4.1.4756.20.610.20.1.25 | Columneoe1GSFxSDLocal | read-only | current | Eoe1/GS card fiber Signal Detection: 0:Fiber Unplugged 1:Signal Detected |
| 1.3.6.1.4.1.4756.20.610.20.1.26 | Columneoe1GSFxLaserLocal | read-only | current | Eoe1/GS card fiber Laser status: 0:Normal 1:error |
| 1.3.6.1.4.1.4756.20.610.20.1.27 | Columneoe1GSFxLinkLocal | read-only | current | Eoe1/GS card fiber link status: 0:Link Down 1:Link Up |
| 1.3.6.1.4.1.4756.20.610.20.1.28 | Columneoe1GSFxActiveLocal | read-write | current | Eoe1/GS card fiber port active: 0:disable 1:enable |
| 1.3.6.1.4.1.4756.20.610.20.1.29 | Columneoe1GSFxLaserOutputLocal | read-write | current | Eoe1/GS card fiber Laser Output active: 0:disable 1:enable |
| 1.3.6.1.4.1.4756.20.610.20.1.30 | Columneoe1GSFxALSLocal | read-write | current | Eoe1/GS card fiber Auto Laser Shutdown active: 0:OFF 1:ON |
| 1.3.6.1.4.1.4756.20.610.20.1.31 | Columneoe1GSFxFlowCtrlLocal | read-write | current | Eoe1/GS card fiber Flow Control active: 0:disable 1:enable |
| 1.3.6.1.4.1.4756.20.610.20.1.32 | Columneoe1GSFxTagLocal | read-write | current | Eoe1/GS card fiber Tag active: 0:UnTag 1:Tag 2:No Touch |
| 1.3.6.1.4.1.4756.20.610.20.1.33 | Columneoe1GSFxTagInsertLocal | read-write | current | Eoe1/GS card fiber Tag Insert active: 0:Disable 1:Enable |
| 1.3.6.1.4.1.4756.20.610.20.1.34 | Columneoe1GSBandwidthFUNLocal | read-write | current | Eoe1/GS card bandwidth mode: 1:disable(0), 2:32k*N(0~255)(1), 3:521k*N(0~200)(2), |
| 1.3.6.1.4.1.4756.20.610.20.1.35 | Columneoe1GSBandwidthLocal | read-write | current | Eoe1/GS bandwidth: bandwidth mode is 32k*N , The bandwidth is restricted to 0 ~ 255 bandwidth mode is 512k*N , The bandwidth is restricted to 0 ~ 200 |
| 1.3.6.1.4.1.4756.20.610.20.1.36 | Columneoe1GSBandwidthSpeedLocal | read-only | current | Eoe1/GS bandwidthspeed: |
| 1.3.6.1.4.1.4756.20.610.20.1.37 | Columneoe1GSVlanFUNLocal | read-write | current | Eoe1/GS card Vlan mode: 0:Disable 1:Enable |
| 1.3.6.1.4.1.4756.20.610.20.1.38 | Columneoe1GSVlanIDLocal | read-write | current | Eoe1/GS card VLAN ID: The ID is restricted to 1 ~ 4095 |
| 1.3.6.1.4.1.4756.20.610.20.1.39 | Columneoe1GSRemoteLinkLocal | read-only | current | Eoe1/GS card remote link status: 0:Down 1:Up |
| 1.3.6.1.4.1.4756.20.610.20.1.40 | Columneoe1GSRemotePWRLocal | read-only | current | Eoe1/GS card remote power status: 0:Normal 1:Power Off |
| 1.3.6.1.4.1.4756.20.610.20.1.41 | Columneoe1GSBertFUNLocal | read-write | current | Eoe1/GS card bert mode: 0:Disable 1:Enable |
| 1.3.6.1.4.1.4756.20.610.20.1.42 | Columneoe1GSBertClearLocal | read-write | current | Eoe1/GS card bert data clear: 0:Normal 1:Clear |
| 1.3.6.1.4.1.4756.20.610.20.1.43 | Columneoe1GSLSBToESLocal | read-only | current | Eoe1/GS card, errored seconds of BERT result. |
| 1.3.6.1.4.1.4756.20.610.20.1.44 | Columneoe1GSLSBToSESLocal | read-only | current | Eoe1/GS card, severely errored seconds of BERT result. |
| 1.3.6.1.4.1.4756.20.610.20.1.45 | Columneoe1GSRmonFUNLocal | read-write | current | Eoe1/GS card Rmon mode: 0:Disable 1:Enable |
| 1.3.6.1.4.1.4756.20.610.20.1.46 | Columneoe1GSRmonRxPKTClearLocal | read-write | current | Eoe1/GS card rmon rx packet clear: 0:Normal 1:Clear |
| 1.3.6.1.4.1.4756.20.610.20.1.47 | Columneoe1GSRmonRxByteClearLocal | read-write | current | Eoe1/GS card rmon rx byte clear: 0:Normal 1:Clear |
| 1.3.6.1.4.1.4756.20.610.20.1.48 | Columneoe1GSRmonRxPKTLocal | read-only | current | Eoe1/GS card RMON Rx packet counter. |
| 1.3.6.1.4.1.4756.20.610.20.1.49 | Columneoe1GSRmonRxByteLocal | read-only | current | Eoe1/GS card RMON Rx byte counter. |
| 1.3.6.1.4.1.4756.20.610.20.1.50 | Columneoe1GSFxDDVenderNameLocal | read-only | current | Eoe1/GS card Fiber SFP Vender Name. |
| 1.3.6.1.4.1.4756.20.610.20.1.51 | Columneoe1GSFxDDVenderPartNoLocal | read-only | current | Eoe1/GS card Fiber SFP Vender Part Number. |
| 1.3.6.1.4.1.4756.20.610.20.1.52 | Columneoe1GSFxDDSFPTypeLocal | read-only | current | Eoe1/GS card Fiber SFP Type . 0:Multi Mode 1:Single Mode 2:None |
| 1.3.6.1.4.1.4756.20.610.20.1.53 | Columneoe1GSFxDDWaveLength1Local | read-only | current | Eoe1/GS card Fiber SFP Wave Length 1. |
| 1.3.6.1.4.1.4756.20.610.20.1.54 | Columneoe1GSFxDDWaveLength2Local | read-only | current | Eoe1/GS card Fiber SFP Wave Length 2. |
| 1.3.6.1.4.1.4756.20.610.20.1.55 | Columneoe1GSFxDDLinkLengthLocal | read-only | current | Eoe1/GS card Fiber SFP Link Length. |
| 1.3.6.1.4.1.4756.20.610.20.1.56 | Columneoe1GSFxDDModelIDLocal | read-only | current | Eoe1/GS card Fiber SFP Model ID. |
| 1.3.6.1.4.1.4756.20.610.20.1.57 | Columneoe1GSFxDDVersionLocal | read-only | current | Eoe1/GS card Fiber SFP Model Version. |
| 1.3.6.1.4.1.4756.20.610.20.1.58 | Columneoe1GSFxDDModelTypeLocal | read-only | current | Eoe1/GS card Fiber SFP Model Type. |
| 1.3.6.1.4.1.4756.20.610.20.1.59 | Columneoe1GSFxDDTxPowerLocal | read-only | current | Eoe1/GS card Fiber SFP Digital/Diagnostic Transmit Power. |
| 1.3.6.1.4.1.4756.20.610.20.1.60 | Columneoe1GSFxDDRxPowerLocal | read-only | current | Eoe1/GS card Fiber SFP Digital/Diagnostic Receive Power. |
| 1.3.6.1.4.1.4756.20.610.20.1.61 | Columneoe1GSFxDDRxSensLocal | read-only | current | Eoe1/GS card Fiber SFP Digital/Diagnostic Receive Sensitivity. |
| 1.3.6.1.4.1.4756.20.610.20.1.62 | Columneoe1GSFxDDRxPwrMarginLocal | read-only | current | Eoe1/GS card Fiber SFP Digital/Diagnostic Receive Power Margin. |
| 1.3.6.1.4.1.4756.20.610.20.1.63 | Columneoe1GSFxDDTempLocal | read-only | current | Eoe1/GS card Fiber SFP Digital/Diagnostic Temperature. |
| 1.3.6.1.4.1.4756.20.610.20.1.64 | Columneoe1GSFxDDBIASLocal | read-only | current | Eoe1/GS card Fiber SFP Digital/Diagnostic BIAS. |
| 1.3.6.1.4.1.4756.20.610.20.1.65 | Columneoe1GSFxDDVoltageLocal | read-only | current | Eoe1/GS card Fiber SFP Digital/Diagnostic Voltage. |
| 1.3.6.1.4.1.4756.20.611 | Nodeeoe1GSRemoteCards | |||
| 1.3.6.1.4.1.4756.20.611.20 | Tableeoe1GSRemoteTable | not-accessible | current | A list of local FRM220-EOE1/GS card entries. The number of entries is eoe1GS-No-L. |
| 1.3.6.1.4.1.4756.20.611.20.1 | Roweoe1GSRemoteEntry | not-accessible | current | An entry containing management information applicable to a particular local FRM220-Eoe1GS series card. |
| 1.3.6.1.4.1.4756.20.611.20.1.1 | Columneoe1GSChassisIndexRemote | read-only | current | A unique value for each card. It starts from 0 to 9 contiguously. |
| 1.3.6.1.4.1.4756.20.611.20.1.2 | Columneoe1GSSlotIndexRemote | read-only | current | A unique value for each card. It starts from 1 to 20 contiguously. |
| 1.3.6.1.4.1.4756.20.611.20.1.3 | Columneoe1GSCardHWVerRemote | read-only | current | Eoe1/GS card hardware version x.xxx |
| 1.3.6.1.4.1.4756.20.611.20.1.4 | Columneoe1GSCardFWVerRemote | read-only | current | Eoe1/GS card firmware version x.xxx |
| 1.3.6.1.4.1.4756.20.611.20.1.5 | Columneoe1GSCardCPLDVerRemote | read-only | current | Eoe1/GS card CPLD version x.xxx |
| 1.3.6.1.4.1.4756.20.611.20.1.6 | Columneoe1GSCardFPGAVerRemote | read-only | current | Eoe1/GS card FPGA version x.xxx |
| 1.3.6.1.4.1.4756.20.611.20.1.7 | Columneoe1GSPortResetRemote | read-write | current | Eoe1/GS card system status: 0:Off 1:Trigger |
| 1.3.6.1.4.1.4756.20.611.20.1.8 | Columneoe1GSSetToDefaultRemote | read-write | current | Eoe1/GS card port set to default: 0:Off 1:Trigger |
| 1.3.6.1.4.1.4756.20.611.20.1.9 | Columneoe1GSLOSRemote | read-only | current | Eoe1/GS card LOS status: 0:No 1:Yes |
| 1.3.6.1.4.1.4756.20.611.20.1.10 | Columneoe1GSLOFRemote | read-only | current | Eoe1/GS card LOF status: 0:No 1:Yes |
| 1.3.6.1.4.1.4756.20.611.20.1.11 | Columneoe1GSAISRemote | read-only | current | Eoe1/GS card AIS status: 0:No 1:Yes |
| 1.3.6.1.4.1.4756.20.611.20.1.12 | Columneoe1GSRAIRemote | read-only | current | Eoe1/GS card RAI status: 0:No 1:Yes |
| 1.3.6.1.4.1.4756.20.611.20.1.13 | Columneoe1GSCRCRemote | read-only | current | Eoe1/GS card CRC status: 0:No 1:Yes |
| 1.3.6.1.4.1.4756.20.611.20.1.14 | Columneoe1GSBPVRemote | read-only | current | Eoe1/GS card BPV status: 0:No 1:Yes |
| 1.3.6.1.4.1.4756.20.611.20.1.15 | Columneoe1GSLoopStatusRemote | read-only | current | Eoe1/GS card Loop status: 0:No 1:Yes |
| 1.3.6.1.4.1.4756.20.611.20.1.16 | Columneoe1GSE1ModeRemote | read-write | current | Eoe1/GS card E1 mode: 0:Unframe 1:Frame |
| 1.3.6.1.4.1.4756.20.611.20.1.17 | Columneoe1GSE1LoopDetectionRemote | read-write | current | Eoe1/GS card E1 loop detection: 0:Disable 1:Enalbe |
| 1.3.6.1.4.1.4756.20.611.20.1.18 | Columneoe1GSE1HDLCRemote | read-write | current | Eoe1/GS Series card E1 HDLC: 0:Inverse 1:Consisten |
| 1.3.6.1.4.1.4756.20.611.20.1.19 | Columneoe1GSTimingSourceRemote | read-write | current | Eoe1/GS card timing source: 0:Recovery from E1 receive 1:Internal oscillator |
| 1.3.6.1.4.1.4756.20.611.20.1.20 | Columneoe1GSFailOverRemote | read-write | current | Eoe1/GS card failover: 0:Disalbe 1:Enable |
| 1.3.6.1.4.1.4756.20.611.20.1.21 | Columneoe1GSEncapsulationRemote | read-write | current | Eoe1/GS card encapsulation: 0:GFP 1:HDLC |
| 1.3.6.1.4.1.4756.20.611.20.1.22 | Columneoe1GSNetManageRemote | read-write | current | Eoe1/GS Series card net manage: 0:Disable 1:Enable |
| 1.3.6.1.4.1.4756.20.611.20.1.23 | Columneoe1GSFxModelRemote | read-only | current | Eoe1/GS card SFP model: 0:No Model 1:OnLine |
| 1.3.6.1.4.1.4756.20.611.20.1.24 | Columneoe1GSFxSDRemote | read-only | current | Eoe1/GS card fiber Signal Detection: 0:Fiber Unplugged 1:Signal Detected |
| 1.3.6.1.4.1.4756.20.611.20.1.25 | Columneoe1GSFxLaserRemote | read-only | current | Eoe1/GS card fiber Laser status: 0:Normal 1:error |
| 1.3.6.1.4.1.4756.20.611.20.1.26 | Columneoe1GSFxLinkRemote | read-only | current | Eoe1/GS card fiber link status: 0:Link Down 1:Link Up |
| 1.3.6.1.4.1.4756.20.611.20.1.27 | Columneoe1GSFxActiveRemote | read-write | current | Eoe1/GS card fiber port active: 0:disable 1:enable |
| 1.3.6.1.4.1.4756.20.611.20.1.28 | Columneoe1GSFxLaserOutputRemote | read-write | current | Eoe1/GS card fiber Laser Output active: 0:disable 1:enable |
| 1.3.6.1.4.1.4756.20.611.20.1.29 | Columneoe1GSFxALSRemote | read-write | current | Eoe1/GS card fiber Auto Laser Shutdown active: 0:OFF 1:ON |
| 1.3.6.1.4.1.4756.20.611.20.1.30 | Columneoe1GSFxFlowCtrlRemote | read-write | current | Eoe1/GS card fiber Flow Control active: 0:disable 1:enable |
| 1.3.6.1.4.1.4756.20.611.20.1.31 | Columneoe1GSFxTagRemote | read-write | current | Eoe1/GS card fiber Tag active: 0:UnTag 1:Tag 2:No Touch |
| 1.3.6.1.4.1.4756.20.611.20.1.32 | Columneoe1GSFxTagInsertRemote | read-write | current | Eoe1/GS card fiber Tag Insert active: 0:Disable 1:Enable |
| 1.3.6.1.4.1.4756.20.611.20.1.33 | Columneoe1GSBandwidthFUNRemote | read-write | current | Eoe1/GS card bandwidth mode: 1:disable(0), 2:32k*N(0~255)(1), 3:521k*N(0~200)(2), |
| 1.3.6.1.4.1.4756.20.611.20.1.34 | Columneoe1GSBandwidthRemote | read-write | current | Eoe1/GS bandwidth: bandwidth mode is 32k*N , The bandwidth is restricted to 0 ~ 255 bandwidth mode is 512k*N , The bandwidth is restricted to 0 ~ 200 |
| 1.3.6.1.4.1.4756.20.611.20.1.35 | Columneoe1GSBandwidthSpeedRemote | read-only | current | Eoe1/GS bandwidthspeed: |
| 1.3.6.1.4.1.4756.20.611.20.1.36 | Columneoe1GSVlanFUNRemote | read-write | current | Eoe1/GS card Vlan mode: 0:Disable 1:Enable |
| 1.3.6.1.4.1.4756.20.611.20.1.37 | Columneoe1GSVlanIDRemote | read-write | current | Eoe1/GS card VLAN ID: The ID is restricted to 1 ~ 4095 |
| 1.3.6.1.4.1.4756.20.611.20.1.38 | Columneoe1GSRemoteLinkRemote | read-only | current | Eoe1/GS card remote link status: 0:Down 1:Up |
| 1.3.6.1.4.1.4756.20.611.20.1.39 | Columneoe1GSRemotePWRRemote | read-only | current | Eoe1/GS card remote power status: 0:Normal 1:Power Off |
| 1.3.6.1.4.1.4756.20.611.20.1.40 | Columneoe1GSRmonFUNRemote | read-write | current | Eoe1/GS card Rmon mode: 0:Disable 1:Enable |
| 1.3.6.1.4.1.4756.20.611.20.1.41 | Columneoe1GSRmonRxPKTClearRemote | read-write | current | Eoe1/GS card rmon rx packet clear: 0:Normal 1:Clear |
| 1.3.6.1.4.1.4756.20.611.20.1.42 | Columneoe1GSRmonRxByteClearRemote | read-write | current | Eoe1/GS card rmon rx byte clear: 0:Normal 1:Clear |
| 1.3.6.1.4.1.4756.20.611.20.1.43 | Columneoe1GSRmonRxPKTRemote | read-only | current | Eoe1/GS card RMON Rx packet counter. |
| 1.3.6.1.4.1.4756.20.611.20.1.44 | Columneoe1GSRmonRxByteRemote | read-only | current | Eoe1/GS card RMON Rx byte counter. |
| 1.3.6.1.4.1.4756.20.611.20.1.45 | Columneoe1GSFxDDVenderNameRemote | read-only | current | Eoe1/GS card Fiber SFP Vender Name. |
| 1.3.6.1.4.1.4756.20.611.20.1.46 | Columneoe1GSFxDDVenderPartNoRemote | read-only | current | Eoe1/GS card Fiber SFP Vender Part Number. |
| 1.3.6.1.4.1.4756.20.611.20.1.47 | Columneoe1GSFxDDSFPTypeRemote | read-only | current | Eoe1/GS card Fiber SFP Vender Part Number. 0:Multi Mode 1:Single Mode 2:None |
| 1.3.6.1.4.1.4756.20.611.20.1.48 | Columneoe1GSFxDDWaveLength1Remote | read-only | current | Eoe1/GS card Fiber SFP Wave Length 1. |
| 1.3.6.1.4.1.4756.20.611.20.1.49 | Columneoe1GSFxDDWaveLength2Remote | read-only | current | Eoe1/GS card Fiber SFP Wave Length 2. |
| 1.3.6.1.4.1.4756.20.611.20.1.50 | Columneoe1GSFxDDLinkLengthRemote | read-only | current | Eoe1/GS card Fiber SFP Link Length. |
| 1.3.6.1.4.1.4756.20.611.20.1.51 | Columneoe1GSFxDDModelIDRemote | read-only | current | Eoe1/GS card Fiber SFP Model ID. |
| 1.3.6.1.4.1.4756.20.611.20.1.52 | Columneoe1GSFxDDVersionRemote | read-only | current | Eoe1/GS card Fiber SFP Model Version. |
| 1.3.6.1.4.1.4756.20.611.20.1.53 | Columneoe1GSFxDDModelTypeRemote | read-only | current | Eoe1/GS card Fiber SFP Model Type. |
| 1.3.6.1.4.1.4756.20.611.20.1.54 | Columneoe1GSFxDDTxPowerRemote | read-only | current | Eoe1/GS card Fiber SFP Digital/Diagnostic Transmit Power. |
| 1.3.6.1.4.1.4756.20.611.20.1.55 | Columneoe1GSFxDDRxPowerRemote | read-only | current | Eoe1/GS card Fiber SFP Digital/Diagnostic Receive Power. |
| 1.3.6.1.4.1.4756.20.611.20.1.56 | Columneoe1GSFxDDRxSensRemote | read-only | current | Eoe1/GS card Fiber SFP Digital/Diagnostic Receive Sensitivity. |
| 1.3.6.1.4.1.4756.20.611.20.1.57 | Columneoe1GSFxDDRxPwrMarginRemote | read-only | current | Eoe1/GS card Fiber SFP Digital/Diagnostic Receive Power Margin. |
| 1.3.6.1.4.1.4756.20.611.20.1.58 | Columneoe1GSFxDDTempRemote | read-only | current | Eoe1/GS card Fiber SFP Digital/Diagnostic Temperature. |
| 1.3.6.1.4.1.4756.20.611.20.1.59 | Columneoe1GSFxDDBIASRemote | read-only | current | Eoe1/GS card Fiber SFP Digital/Diagnostic BIAS. |
| 1.3.6.1.4.1.4756.20.611.20.1.60 | Columneoe1GSFxDDVoltageRemote | read-only | current | Eoe1/GS card Fiber SFP Digital/Diagnostic Voltage. |
| 1.3.6.1.4.1.4756.20.620 | Nodef40G1Q4SCards | |||
| 1.3.6.1.4.1.4756.20.620.20 | Tablef40G1Q4STable | not-accessible | current | A list of local FRM220-40G1Q4S card entries. The number of entries is f40G1Q4S-No-L. |
| 1.3.6.1.4.1.4756.20.620.20.1 | Rowf40G1Q4SEntry | not-accessible | current | An entry containing management information applicable to a particular local FRM220-40G1Q4S series card. |
| 1.3.6.1.4.1.4756.20.620.20.1.1 | Columnf40G1Q4SChassisIndex | read-only | current | A unique value for each card. It starts from 0 to 9 contiguously. |
| 1.3.6.1.4.1.4756.20.620.20.1.2 | Columnf40G1Q4SSlotIndex | read-only | current | A unique value for each card. It starts from 1 to 20 contiguously. |
| 1.3.6.1.4.1.4756.20.620.20.1.3 | Columnf40G1Q4SCardHWVer | read-only | current | 40G1Q4S card hardware version x.xxx |
| 1.3.6.1.4.1.4756.20.620.20.1.4 | Columnf40G1Q4SCardFWVer | read-only | current | 40G1Q4S card firmware version x.xxx |
| 1.3.6.1.4.1.4756.20.620.20.1.5 | Columnf40G1Q4SCardCPLDVer | read-only | current | 40G1Q4S card CPLD version x.xxx |
| 1.3.6.1.4.1.4756.20.620.20.1.6 | Columnf40G1Q4SCardFPGAVer | read-only | current | 40G1Q4S card FPGA version x.xxx |
| 1.3.6.1.4.1.4756.20.620.20.1.7 | Columnf40G1Q4SPortReset | read-write | current | 40G1Q4S card system status: 0:Off 1:Trigger |
| 1.3.6.1.4.1.4756.20.620.20.1.8 | Columnf40G1Q4SSetToDefault | read-write | current | 40G1Q4S card port set to default: 0:Off 1:Trigger |
| 1.3.6.1.4.1.4756.20.620.20.1.9 | Columnf40G1Q4SQSFPP1Present | read-only | current | 40G1Q4S QSFP Plus 1 Port Presented. 0:No 1:Have |
| 1.3.6.1.4.1.4756.20.620.20.1.10 | Columnf40G1Q4SQSFPP2Present | read-only | current | 40G1Q4S QSFP Plus 2 Port Presented. 0:No 1:Have |
| 1.3.6.1.4.1.4756.20.620.20.1.11 | Columnf40G1Q4SQSFPP3Present | read-only | current | 40G1Q4S QSFP Plus 3 Port Presented. 0:No 1:Have |
| 1.3.6.1.4.1.4756.20.620.20.1.12 | Columnf40G1Q4SQSFPP4Present | read-only | current | 40G1Q4S QSFP Plus 4 Port Presented. 0:No 1:Have |
| 1.3.6.1.4.1.4756.20.620.20.1.13 | Columnf40G1Q4SSFPP1Present | read-only | current | 40G1Q4S SFP Plus 4 Port Presented. 0:No 1:Have |
| 1.3.6.1.4.1.4756.20.620.20.1.14 | Columnf40G1Q4SSFPP2Present | read-only | current | 40G1Q4S SFP Plus 2 Port Presented. 0:No 1:Have |
| 1.3.6.1.4.1.4756.20.620.20.1.15 | Columnf40G1Q4SSFPP3Present | read-only | current | 40G1Q4S SFP Plus 3 Port Presented. 0:No 1:Have |
| 1.3.6.1.4.1.4756.20.620.20.1.16 | Columnf40G1Q4SSFPP4Present | read-only | current | 40G1Q4S SFP Plus 4 Port Presented. 0:No 1:Have |
| 1.3.6.1.4.1.4756.20.620.20.1.17 | Columnf40G1Q4SQSFPP1DDM | read-only | current | 40G1Q4S QSFP Plus 1 Port Digital Diagnostic Monitor. 0:No 1:Yes |
| 1.3.6.1.4.1.4756.20.620.20.1.18 | Columnf40G1Q4SQSFPP2DDM | read-only | current | 40G1Q4S QSFP Plus 2 Port Digital Diagnostic Monitor. 0:No 1:Yes |
| 1.3.6.1.4.1.4756.20.620.20.1.19 | Columnf40G1Q4SQSFPP3DDM | read-only | current | 40G1Q4S QSFP Plus 3 Port Digital Diagnostic Monitor. 0:No 1:Yes |
| 1.3.6.1.4.1.4756.20.620.20.1.20 | Columnf40G1Q4SQSFPP4DDM | read-only | current | 40G1Q4S QSFP Plus 4 Port Digital Diagnostic Monitor. 0:No 1:Yes |
| 1.3.6.1.4.1.4756.20.620.20.1.21 | Columnf40G1Q4SSFPP1DDM | read-only | current | 40G1Q4S SFP Plus 1 Port Digital Diagnostic Monitor. 0:No 1:Yes |
| 1.3.6.1.4.1.4756.20.620.20.1.22 | Columnf40G1Q4SSFPP2DDM | read-only | current | 40G1Q4S SFP Plus 2 Port Digital Diagnostic Monitor. 0:No 1:Yes |
| 1.3.6.1.4.1.4756.20.620.20.1.23 | Columnf40G1Q4SSFPP3DDM | read-only | current | 40G1Q4S SFP Plus 3 Port Digital Diagnostic Monitor. 0:No 1:Yes |
| 1.3.6.1.4.1.4756.20.620.20.1.24 | Columnf40G1Q4SSFPP4DDM | read-only | current | 40G1Q4S SFP Plus 4 Port Digital Diagnostic Monitor. 0:No 1:yes |
| 1.3.6.1.4.1.4756.20.620.20.1.25 | Columnf40G1Q4SQSFPP1TxFault | read-only | current | 40G1Q4S QSFP Plus 1 Port Transceiver Failure. 0:Normal 1:Failure |
| 1.3.6.1.4.1.4756.20.620.20.1.26 | Columnf40G1Q4SQSFPP2TxFault | read-only | current | 40G1Q4S QSFP Plus 2 Port Transceiver Failure. 0:Normal 1:Failure |
| 1.3.6.1.4.1.4756.20.620.20.1.27 | Columnf40G1Q4SQSFPP3TxFault | read-only | current | 40G1Q4S QSFP Plus 3 Port Transceiver Failure. 0:Normal 1:Failure |
| 1.3.6.1.4.1.4756.20.620.20.1.28 | Columnf40G1Q4SQSFPP4TxFault | read-only | current | 40G1Q4S QSFP Plus 4 Port Transceiver Failure. 0:Normal 1:Failure |
| 1.3.6.1.4.1.4756.20.620.20.1.29 | Columnf40G1Q4SSFPP1TxFault | read-only | current | 40G1Q4S SFP Plus 1 Port Transceiver Failure. 0:Normal 1:Failure |
| 1.3.6.1.4.1.4756.20.620.20.1.30 | Columnf40G1Q4SSFPP2TxFault | read-only | current | 40G1Q4S SFP Plus 2 Port Transceiver Failure. 0:Normal 1:Failure |
| 1.3.6.1.4.1.4756.20.620.20.1.31 | Columnf40G1Q4SSFPP3TxFault | read-only | current | 40G1Q4S SFP Plus 3 Port Transceiver Failure. 0:Normal 1:Failure |
| 1.3.6.1.4.1.4756.20.620.20.1.32 | Columnf40G1Q4SSFPP4TxFault | read-only | current | 40G1Q4S SFP Plus 4 Port Transceiver Failure. 0:Normal 1:Failure |
| 1.3.6.1.4.1.4756.20.620.20.1.33 | Columnf40G1Q4SQSFPP1LOS | read-only | current | 40G1Q4S QSFP Plus 1 Port Loss of Signal. 0:Yes 1:No |
| 1.3.6.1.4.1.4756.20.620.20.1.34 | Columnf40G1Q4SQSFPP2LOS | read-only | current | 40G1Q4S QSFP Plus 2 Port Loss of Signal. yes(0), no(1) |
| 1.3.6.1.4.1.4756.20.620.20.1.35 | Columnf40G1Q4SQSFPP3LOS | read-only | current | 40G1Q4S QSFP Plus 3 Port Loss of Signal. 0:Yes 1:No |
| 1.3.6.1.4.1.4756.20.620.20.1.36 | Columnf40G1Q4SQSFPP4LOS | read-only | current | 40G1Q4S QSFP Plus 4 Port Loss of Signal. 0:Yes 1:No |
| 1.3.6.1.4.1.4756.20.620.20.1.37 | Columnf40G1Q4SSFPP1LOS | read-only | current | 40G1Q4S SFP Plus 1 Port Loss of Signal. 0:Yes 1:No |
| 1.3.6.1.4.1.4756.20.620.20.1.38 | Columnf40G1Q4SSFPP2LOS | read-only | current | 40G1Q4S SFP Plus 2 Port Loss of Signal. 0:Yes 1:No |
| 1.3.6.1.4.1.4756.20.620.20.1.39 | Columnf40G1Q4SSFPP3LOS | read-only | current | 40G1Q4S SFP Plus 3 Port Loss of Signal. 0:Yes 1:No |
| 1.3.6.1.4.1.4756.20.620.20.1.40 | Columnf40G1Q4SSFPP4LOS | read-only | current | 40G1Q4S SFP Plus 4 Port Loss of Signal. 0:Yes 1:No |
| 1.3.6.1.4.1.4756.20.620.20.1.41 | Columnf40G1Q4SQSFPP1CDRLock | read-only | current | 40G1Q4S QSFP Plus 1 Port Cable Distribution Rack. 0:Not Locked 1:Locked |
| 1.3.6.1.4.1.4756.20.620.20.1.42 | Columnf40G1Q4SQSFPP2CDRLock | read-only | current | 40G1Q4S QSFP Plus 2 Port Cable Distribution Rack. 0:Not Locked 1:Locked |
| 1.3.6.1.4.1.4756.20.620.20.1.43 | Columnf40G1Q4SQSFPP3CDRLock | read-only | current | 40G1Q4S QSFP Plus 3 Port Cable Distribution Rack. 0:Not Locked 1:Locked |
| 1.3.6.1.4.1.4756.20.620.20.1.44 | Columnf40G1Q4SQSFPP4CDRLock | read-only | current | 40G1Q4S QSFP Plus 4 Port Cable Distribution Rack. 0:Not Locked 1:Locked |
| 1.3.6.1.4.1.4756.20.620.20.1.45 | Columnf40G1Q4SSFPP1CDRLock | read-only | current | 40G1Q4S SFP Plus 1 Port Cable Distribution Rack. 0:Not Locked 1:Locked |
| 1.3.6.1.4.1.4756.20.620.20.1.46 | Columnf40G1Q4SSFPP2CDRLock | read-only | current | 40G1Q4S SFP Plus 2 Port Cable Distribution Rack. 0:Not Locked 1:Locked |
| 1.3.6.1.4.1.4756.20.620.20.1.47 | Columnf40G1Q4SSFPP3CDRLock | read-only | current | 40G1Q4S SFP Plus 3 Port Cable Distribution Rack. 0:Not Locked 1:Locked |
| 1.3.6.1.4.1.4756.20.620.20.1.48 | Columnf40G1Q4SSFPP4CDRLock | read-only | current | 40G1Q4S SFP Plus 4 Port Cable Distribution Rack. 0:Not Locked 1:Locked |
| 1.3.6.1.4.1.4756.20.620.20.1.49 | Columnf40G1Q4SPortActive | read-write | current | 40G1Q4S Port Active feature. 0:Disable 1:Enable |
| 1.3.6.1.4.1.4756.20.620.20.1.50 | Columnf40G1Q4SDataRateStatus | read-only | current | 40G1Q4S Port Date Rate status. |
| 1.3.6.1.4.1.4756.20.620.20.1.51 | Columnf40G1Q4SDataRate | read-write | current | 40G1Q4S Port Date Rate setting. 0:Ethernet 10GE 1:SONET/SDH OC192/STM64 2:Fiber Ch 16G 3:Fiber Ch 10G 4:Fiber Ch 8G 5:CPRI x16 |
| 1.3.6.1.4.1.4756.20.620.20.1.52 | Columnf40G1Q4SSFPLBT | read-write | current | 40G1Q4S SFP Plus Loopback Test Function. 0:Disable 1:Enable |
| 1.3.6.1.4.1.4756.20.620.20.1.53 | Columnf40G1Q4SQSFPLBT | read-write | current | 40G1Q4S QSFP Plus Loopback Test Function. 0:Disable 1:Enable |
| 1.3.6.1.4.1.4756.20.620.20.1.54 | Columnf40G1Q4SSFPQSFPLBT | read-write | current | 40G1Q4S SFP Plus and QSFP Plus Loopback Test Function. 0:Disable 1:Enable |
| 1.3.6.1.4.1.4756.20.620.20.1.55 | Columnf40G1Q4SQSFPPLFP | read-write | current | 40G1Q4S QSFP Plus Link Fault Pass-Throuth Function. 0:Disable 1:Enable |
| 1.3.6.1.4.1.4756.20.620.20.1.56 | Columnf40G1Q4SSFPP1LFP | read-write | current | 40G1Q4S SFP Plus 1 Link Fault Pass-Throuth Function. 0:Disable 1:Enable |
| 1.3.6.1.4.1.4756.20.620.20.1.57 | Columnf40G1Q4SSFPP2LFP | read-write | current | 40G1Q4S SFP Plus 2 Link Fault Pass-Throuth Function. 0:Disable 1:Enable |
| 1.3.6.1.4.1.4756.20.620.20.1.58 | Columnf40G1Q4SSFPP3LFP | read-write | current | 40G1Q4S SFP Plus 3 Link Fault Pass-Throuth Function. 0:Disable 1:Enable |
| 1.3.6.1.4.1.4756.20.620.20.1.59 | Columnf40G1Q4SSFPP4LFP | read-write | current | 40G1Q4S SFP Plus 4 Link Fault Pass-Throuth Function. 0:Disable 1:Enable |
| 1.3.6.1.4.1.4756.20.620.20.1.60 | Columnf40G1Q4SQSFPP1LinkAlarm | read-write | current | 40G1Q4S QSFP Plus 1 Link Alarm function. 0:Disable 1:Enable |
| 1.3.6.1.4.1.4756.20.620.20.1.61 | Columnf40G1Q4SQSFPP2LinkAlarm | read-write | current | 40G1Q4S QSFP Plus 2 Link Alarm function. 0:Disable 1:Enable |
| 1.3.6.1.4.1.4756.20.620.20.1.62 | Columnf40G1Q4SQSFPP3LinkAlarm | read-write | current | 40G1Q4S QSFP Plus 3 Link Alarm function. 0:Disable 1:Enable |
| 1.3.6.1.4.1.4756.20.620.20.1.63 | Columnf40G1Q4SQSFPP4LinkAlarm | read-write | current | 40G1Q4S QSFP Plus 4 Link Alarm function. 0:Disable 1:Enable |
| 1.3.6.1.4.1.4756.20.620.20.1.64 | Columnf40G1Q4SSFPP1LinkAlarm | read-write | current | 40G1Q4S SFP Plus 1 Link Alarm function. 0:Disable 1:Enable |
| 1.3.6.1.4.1.4756.20.620.20.1.65 | Columnf40G1Q4SSFPP2LinkAlarm | read-write | current | 40G1Q4S SFP Plus 2 Link Alarm function. 0:Disable 1:Enable |
| 1.3.6.1.4.1.4756.20.620.20.1.66 | Columnf40G1Q4SSFPP3LinkAlarm | read-write | current | 40G1Q4S SFP Plus 3 Link Alarm function. 0:Disable 1:Enable |
| 1.3.6.1.4.1.4756.20.620.20.1.67 | Columnf40G1Q4SSFPP4LinkAlarm | read-write | current | 40G1Q4S SFP Plus 4 Link Alarm function. 0:Disable 1:Enable |
| 1.3.6.1.4.1.4756.20.620.20.1.68 | Columnf40G1Q4SQSFPP1LockAlarm | read-write | current | 40G1Q4S QSFP Plus 1 Lock Alarm function. 0:Disable 1:Enable |
| 1.3.6.1.4.1.4756.20.620.20.1.69 | Columnf40G1Q4SQSFPP2LockAlarm | read-write | current | 40G1Q4S QSFP Plus 1 Lock Alarm function. 0:Disable 1:Enable |
| 1.3.6.1.4.1.4756.20.620.20.1.70 | Columnf40G1Q4SQSFPP3LockAlarm | read-write | current | 40G1Q4S QSFP Plus 3 Lock Alarm function. 0:Disable 1:Enable |
| 1.3.6.1.4.1.4756.20.620.20.1.71 | Columnf40G1Q4SQSFPP4LockAlarm | read-write | current | 40G1Q4S QSFP Plus 4 Lock Alarm function. 0:Disable 1:Enable |
| 1.3.6.1.4.1.4756.20.620.20.1.72 | Columnf40G1Q4SSFPP1LockAlarm | read-write | current | 40G1Q4S SFP Plus 1 Lock Alarm function. 0:Disable 1:Enable |
| 1.3.6.1.4.1.4756.20.620.20.1.73 | Columnf40G1Q4SSFPP2LockAlarm | read-write | current | 40G1Q4S SFP Plus 2 Lock Alarm function. 0:Disable 1:Enable |
| 1.3.6.1.4.1.4756.20.620.20.1.74 | Columnf40G1Q4SSFPP3LockAlarm | read-write | current | 40G1Q4S SFP Plus 3 Lock Alarm function. 0:Disable 1:Enable |
| 1.3.6.1.4.1.4756.20.620.20.1.75 | Columnf40G1Q4SSFPP4LockAlarm | read-write | current | 40G1Q4S SFP Plus 4 Lock Alarm function. 0:Disable 1:Enable |
| 1.3.6.1.4.1.4756.20.620.20.1.76 | Columnf40G1Q4SQSFPP1TxFAlarm | read-write | current | 40G1Q4S QSFP Plus 1 Transceiver Fault Alarm function. 0:Disable 1:Enable |
| 1.3.6.1.4.1.4756.20.620.20.1.77 | Columnf40G1Q4SQSFPP2TxFAlarm | read-write | current | 40G1Q4S QSFP Plus 2 Transceiver Fault Alarm function. 0:Disable 1:Enable |
| 1.3.6.1.4.1.4756.20.620.20.1.78 | Columnf40G1Q4SQSFPP3TxFAlarm | read-write | current | 40G1Q4S QSFP Plus 3 Transceiver Fault Alarm function. 0:Disable 1:Enable |
| 1.3.6.1.4.1.4756.20.620.20.1.79 | Columnf40G1Q4SQSFPP4TxFAlarm | read-write | current | 40G1Q4S QSFP Plus 4 Transceiver Fault Alarm function. 0:Disable 1:Enable |
| 1.3.6.1.4.1.4756.20.620.20.1.80 | Columnf40G1Q4SSFPP1TxFAlarm | read-write | current | 40G1Q4S SFP Plus 1 Transceiver Fault Alarm function. 0:Disable 1:Enable |
| 1.3.6.1.4.1.4756.20.620.20.1.81 | Columnf40G1Q4SSFPP2TxFAlarm | read-write | current | 40G1Q4S SFP Plus 2 Transceiver Fault Alarm function. 0:Disable 1:Enable |
| 1.3.6.1.4.1.4756.20.620.20.1.82 | Columnf40G1Q4SSFPP3TxFAlarm | read-write | current | 40G1Q4S SFP Plus 3 Transceiver Fault Alarm function. 0:Disable 1:Enable |
| 1.3.6.1.4.1.4756.20.620.20.1.83 | Columnf40G1Q4SSFPP4TxFAlarm | read-write | current | 40G1Q4S SFP Plus 4 Transceiver Fault Alarm function. 0:Disable 1:Enable |
| 1.3.6.1.4.1.4756.20.620.20.1.84 | Columnf40G1Q4SQSFPPVendorName | read-only | current | 40G1Q4S QSFP Plus Vendor Name. |
| 1.3.6.1.4.1.4756.20.620.20.1.85 | Columnf40G1Q4SQSFPPPartNo | read-only | current | 40G1Q4S QSFP Plus Part Number. |
| 1.3.6.1.4.1.4756.20.620.20.1.86 | Columnf40G1Q4SQSFPPVendorSN | read-only | current | 40G1Q4S QSFP Plus Vendor Serial Number. |
| 1.3.6.1.4.1.4756.20.620.20.1.87 | Columnf40G1Q4SQSFPPOpticalType | read-only | current | 40G1Q4S QSFP Plus Optical Type. 0: Multi 1: Single 2: UnKnown |
| 1.3.6.1.4.1.4756.20.620.20.1.88 | Columnf40G1Q4SQSFPPWaveLength1 | read-only | current | 40G1Q4S QSFP Plus Wave Length 1. |
| 1.3.6.1.4.1.4756.20.620.20.1.89 | Columnf40G1Q4SQSFPPWaveLength2 | read-only | current | 40G1Q4S QSFP Plus Wave Length 2. |
| 1.3.6.1.4.1.4756.20.620.20.1.90 | Columnf40G1Q4SQSFPPOM3LinkLength | read-only | current | 40G1Q4S QSFP Plus OM3 Link Length. |
| 1.3.6.1.4.1.4756.20.620.20.1.91 | Columnf40G1Q4SQSFPPTemp | read-only | current | 40G1Q4S QSFP Plus Temperature. |
| 1.3.6.1.4.1.4756.20.620.20.1.92 | Columnf40G1Q4SQSFPPSupplyVol | read-only | current | 40G1Q4S QSFP Plus Supply Voltage. |
| 1.3.6.1.4.1.4756.20.620.20.1.93 | Columnf40G1Q4SQSFPP1TxPower | read-only | current | 40G1Q4S QSFP Plus 1 Transceiver Power. |
| 1.3.6.1.4.1.4756.20.620.20.1.94 | Columnf40G1Q4SQSFPP1RxPower | read-only | current | 40G1Q4S QSFP Plus 1 Receiver Power. |
| 1.3.6.1.4.1.4756.20.620.20.1.95 | Columnf40G1Q4SQSFPP1TxLaserBias | read-only | current | 40G1Q4S QSFP Plus 1 Transceiver Laser BIAS. |
| 1.3.6.1.4.1.4756.20.620.20.1.96 | Columnf40G1Q4SQSFPP2TxPower | read-only | current | 40G1Q4S QSFP Plus 2 Transceiver Power. |
| 1.3.6.1.4.1.4756.20.620.20.1.97 | Columnf40G1Q4SQSFPP2RxPower | read-only | current | 40G1Q4S QSFP Plus 2 Receiver Power. |
| 1.3.6.1.4.1.4756.20.620.20.1.98 | Columnf40G1Q4SQSFPP2TxLaserBias | read-only | current | 40G1Q4S QSFP Plus 2 Transceiver Laser BIAS. |
| 1.3.6.1.4.1.4756.20.620.20.1.99 | Columnf40G1Q4SQSFPP3TxPower | read-only | current | 40G1Q4S QSFP Plus 3 Transceiver Power. |
| 1.3.6.1.4.1.4756.20.620.20.1.100 | Columnf40G1Q4SQSFPP3RxPower | read-only | current | 40G1Q4S QSFP Plus 3 Receiver Power. |
| 1.3.6.1.4.1.4756.20.620.20.1.101 | Columnf40G1Q4SQSFPP3TxLaserBias | read-only | current | 40G1Q4S QSFP Plus 3 Transceiver Laser BIAS. |
| 1.3.6.1.4.1.4756.20.620.20.1.102 | Columnf40G1Q4SQSFPP4TxPower | read-only | current | 40G1Q4S QSFP Plus 4 Transceiver Power. |
| 1.3.6.1.4.1.4756.20.620.20.1.103 | Columnf40G1Q4SQSFPP4RxPower | read-only | current | 40G1Q4S QSFP Plus 4 Receiver Power. |
| 1.3.6.1.4.1.4756.20.620.20.1.104 | Columnf40G1Q4SQSFPP4TxLaserBias | read-only | current | 40G1Q4S QSFP Plus 4 Transceiver Laser BIAS. |
| 1.3.6.1.4.1.4756.20.620.20.1.105 | Columnf40G1Q4SSFPP1VendorName | read-only | current | 40G1Q4S SFP Plus 1 Vendor Name. |
| 1.3.6.1.4.1.4756.20.620.20.1.106 | Columnf40G1Q4SSFPP1PartNo | read-only | current | 40G1Q4S SFP Plus 1 Part Number. |
| 1.3.6.1.4.1.4756.20.620.20.1.107 | Columnf40G1Q4SSFPP1VendorSN | read-only | current | 40G1Q4S SFP Plus 1 Vendor Serial Number. |
| 1.3.6.1.4.1.4756.20.620.20.1.108 | Columnf40G1Q4SSFPP1OpticalType | read-only | current | 40G1Q4S SFP Plus 1 Optical Type: 0: Multi 1: Single 2: UnKnown |
| 1.3.6.1.4.1.4756.20.620.20.1.109 | Columnf40G1Q4SSFPP1WaveLength | read-only | current | 40G1Q4S SFP Plus 1 Wave Length. |
| 1.3.6.1.4.1.4756.20.620.20.1.110 | Columnf40G1Q4SSFPP1WaveLength2 | read-only | current | 40G1Q4S SFP Plus 1 Wave Length2. |
| 1.3.6.1.4.1.4756.20.620.20.1.111 | Columnf40G1Q4SSFPP1LinkLength | read-only | current | 40G1Q4S SFP Plus 1 Link Length. |
| 1.3.6.1.4.1.4756.20.620.20.1.112 | Columnf40G1Q4SSFPP1TxPower | read-only | current | 40G1Q4S SFP Plus 1 Transceiver Power. |
| 1.3.6.1.4.1.4756.20.620.20.1.113 | Columnf40G1Q4SSFPP1RxPower | read-only | current | 40G1Q4S SFP Plus 1 Receiver Power. |
| 1.3.6.1.4.1.4756.20.620.20.1.114 | Columnf40G1Q4SSFPP1RxSens | read-only | current | 40G1Q4S SFP Plus 1 Receiver Sensitivity. |
| 1.3.6.1.4.1.4756.20.620.20.1.115 | Columnf40G1Q4SSFPP1RxPwrMargin | read-only | current | 40G1Q4S SFP Plus 1 Receiver Power Margin. |
| 1.3.6.1.4.1.4756.20.620.20.1.116 | Columnf40G1Q4SSFPP1Temp | read-only | current | 40G1Q4S SFP Plus 1 Temperature. |
| 1.3.6.1.4.1.4756.20.620.20.1.117 | Columnf40G1Q4SSFPP1SupplyVol | read-only | current | 40G1Q4S SFP Plus 1 Supply Voltage. |
| 1.3.6.1.4.1.4756.20.620.20.1.118 | Columnf40G1Q4SSFPP1TxLaserBias | read-only | current | 40G1Q4S SFP Plus 1 Transceiver Laser BIAS. |
| 1.3.6.1.4.1.4756.20.620.20.1.119 | Columnf40G1Q4SSFPP2VendorName | read-only | current | 40G1Q4S SFP Plus 2 Vendor Name. |
| 1.3.6.1.4.1.4756.20.620.20.1.120 | Columnf40G1Q4SSFPP2PartNo | read-only | current | 40G1Q4S SFP Plus 2 Part Number. |
| 1.3.6.1.4.1.4756.20.620.20.1.121 | Columnf40G1Q4SSFPP2VendorSN | read-only | current | 40G1Q4S SFP Plus 2 Vendor Serial Number. |
| 1.3.6.1.4.1.4756.20.620.20.1.122 | Columnf40G1Q4SSFPP2OpticalType | read-only | current | 40G1Q4S SFP Plus 2 Optical Type: 0: Multi 1: Single 2: UnKnown |
| 1.3.6.1.4.1.4756.20.620.20.1.123 | Columnf40G1Q4SSFPP2WaveLength | read-only | current | 40G1Q4S SFP Plus 2 Wave Length. |
| 1.3.6.1.4.1.4756.20.620.20.1.124 | Columnf40G1Q4SSFPP2WaveLength2 | read-only | current | 40G1Q4S SFP Plus 2 Wave Length2. |
| 1.3.6.1.4.1.4756.20.620.20.1.125 | Columnf40G1Q4SSFPP2LinkLength | read-only | current | 40G1Q4S SFP Plus 2 Link Length. |
| 1.3.6.1.4.1.4756.20.620.20.1.126 | Columnf40G1Q4SSFPP2TxPower | read-only | current | 40G1Q4S SFP Plus 2 Transceiver Power. |
| 1.3.6.1.4.1.4756.20.620.20.1.127 | Columnf40G1Q4SSFPP2RxPower | read-only | current | 40G1Q4S SFP Plus 2 Receiver Power. |
| 1.3.6.1.4.1.4756.20.620.20.1.128 | Columnf40G1Q4SSFPP2RxSens | read-only | current | 40G1Q4S SFP Plus 2 Receiver Sensitivity. |
| 1.3.6.1.4.1.4756.20.620.20.1.129 | Columnf40G1Q4SSFPP2RxPwrMargin | read-only | current | 40G1Q4S SFP Plus 2 Receiver Power Margin. |
| 1.3.6.1.4.1.4756.20.620.20.1.130 | Columnf40G1Q4SSFPP2Temp | read-only | current | 40G1Q4S SFP Plus 2 Temperature. |
| 1.3.6.1.4.1.4756.20.620.20.1.131 | Columnf40G1Q4SSFPP2SupplyVol | read-only | current | 40G1Q4S SFP Plus 2 Supply Voltage. |
| 1.3.6.1.4.1.4756.20.620.20.1.132 | Columnf40G1Q4SSFPP2TxLaserBias | read-only | current | 40G1Q4S SFP Plus 2 Transceiver Laser BIAS. |
| 1.3.6.1.4.1.4756.20.620.20.1.133 | Columnf40G1Q4SSFPP3VendorName | read-only | current | 40G1Q4S SFP Plus 3 Vendor Name. |
| 1.3.6.1.4.1.4756.20.620.20.1.134 | Columnf40G1Q4SSFPP3PartNo | read-only | current | 40G1Q4S SFP Plus 3 Part Number. |
| 1.3.6.1.4.1.4756.20.620.20.1.135 | Columnf40G1Q4SSFPP3VendorSN | read-only | current | 40G1Q4S SFP Plus 3 Vendor Serial Number. |
| 1.3.6.1.4.1.4756.20.620.20.1.136 | Columnf40G1Q4SSFPP3OpticalType | read-only | current | 40G1Q4S SFP Plus 3 Optical Type: 0: Multi 1: Single 2: UnKnown |
| 1.3.6.1.4.1.4756.20.620.20.1.137 | Columnf40G1Q4SSFPP3WaveLength | read-only | current | 40G1Q4S SFP Plus 3 Wave Length. |
| 1.3.6.1.4.1.4756.20.620.20.1.138 | Columnf40G1Q4SSFPP3WaveLength2 | read-only | current | 40G1Q4S SFP Plus 3 Wave Length2. |
| 1.3.6.1.4.1.4756.20.620.20.1.139 | Columnf40G1Q4SSFPP3LinkLength | read-only | current | 40G1Q4S SFP Plus 3 Link Length. |
| 1.3.6.1.4.1.4756.20.620.20.1.140 | Columnf40G1Q4SSFPP3TxPower | read-only | current | 40G1Q4S SFP Plus 3 Transceiver Power. |
| 1.3.6.1.4.1.4756.20.620.20.1.141 | Columnf40G1Q4SSFPP3RxPower | read-only | current | 40G1Q4S SFP Plus 3 Receiver Power. |
| 1.3.6.1.4.1.4756.20.620.20.1.142 | Columnf40G1Q4SSFPP3RxSens | read-only | current | 40G1Q4S SFP Plus 3 Receiver Sensitivity. |
| 1.3.6.1.4.1.4756.20.620.20.1.143 | Columnf40G1Q4SSFPP3RxPwrMargin | read-only | current | 40G1Q4S SFP Plus 3 Receiver Power Margin. |
| 1.3.6.1.4.1.4756.20.620.20.1.144 | Columnf40G1Q4SSFPP3Temp | read-only | current | 40G1Q4S SFP Plus 3 Temperature. |
| 1.3.6.1.4.1.4756.20.620.20.1.145 | Columnf40G1Q4SSFPP3SupplyVol | read-only | current | 40G1Q4S SFP Plus 3 Supply Voltage. |
| 1.3.6.1.4.1.4756.20.620.20.1.146 | Columnf40G1Q4SSFPP3TxLaserBias | read-only | current | 40G1Q4S SFP Plus 3 Transceiver Laser BIAS. |
| 1.3.6.1.4.1.4756.20.620.20.1.147 | Columnf40G1Q4SSFPP4VendorName | read-only | current | 40G1Q4S SFP Plus 4 Vendor Name. |
| 1.3.6.1.4.1.4756.20.620.20.1.148 | Columnf40G1Q4SSFPP4PartNo | read-only | current | 40G1Q4S SFP Plus 4 Part Number. |
| 1.3.6.1.4.1.4756.20.620.20.1.149 | Columnf40G1Q4SSFPP4VendorSN | read-only | current | 40G1Q4S SFP Plus 4 Vendor Serial Number. |
| 1.3.6.1.4.1.4756.20.620.20.1.150 | Columnf40G1Q4SSFPP4OpticalType | read-only | current | 40G1Q4S SFP Plus 4 Optical Type: 0: Multi 1: Single 2: UnKnown |
| 1.3.6.1.4.1.4756.20.620.20.1.151 | Columnf40G1Q4SSFPP4WaveLength | read-only | current | 40G1Q4S SFP Plus 4 Wave Length. |
| 1.3.6.1.4.1.4756.20.620.20.1.152 | Columnf40G1Q4SSFPP4WaveLength2 | read-only | current | 40G1Q4S SFP Plus 4 Wave Length2. |
| 1.3.6.1.4.1.4756.20.620.20.1.153 | Columnf40G1Q4SSFPP4LinkLength | read-only | current | 40G1Q4S SFP Plus 4 Link Length. |
| 1.3.6.1.4.1.4756.20.620.20.1.154 | Columnf40G1Q4SSFPP4TxPower | read-only | current | 40G1Q4S SFP Plus 4 Transceiver Power. |
| 1.3.6.1.4.1.4756.20.620.20.1.155 | Columnf40G1Q4SSFPP4RxPower | read-only | current | 40G1Q4S SFP Plus 4 Receiver Power. |
| 1.3.6.1.4.1.4756.20.620.20.1.156 | Columnf40G1Q4SSFPP4RxSens | read-only | current | 40G1Q4S SFP Plus 4 Receiver Sensitivity. |
| 1.3.6.1.4.1.4756.20.620.20.1.157 | Columnf40G1Q4SSFPP4RxPwrMargin | read-only | current | 40G1Q4S SFP Plus 4 Receiver Power Margin. |
| 1.3.6.1.4.1.4756.20.620.20.1.158 | Columnf40G1Q4SSFPP4Temp | read-only | current | 40G1Q4S SFP Plus 4 Temperature. |
| 1.3.6.1.4.1.4756.20.620.20.1.159 | Columnf40G1Q4SSFPP4SupplyVol | read-only | current | 40G1Q4S SFP Plus 4 Supply Voltage. |
| 1.3.6.1.4.1.4756.20.620.20.1.160 | Columnf40G1Q4SSFPP4TxLaserBias | read-only | current | 40G1Q4S SFP Plus 4 Transceiver Laser BIAS. |
| 1.3.6.1.4.1.4756.20.630 | Nodef10GCCards | |||
| 1.3.6.1.4.1.4756.20.630.20 | Tablef10GCTable | not-accessible | current | A list of local FRM220-10GC card entries. The number of entries is f10GC-No-L. |
| 1.3.6.1.4.1.4756.20.630.20.1 | Rowf10GCEntry | not-accessible | current | An entry containing management information applicable to a particular local FRM220-10GC series card. |
| 1.3.6.1.4.1.4756.20.630.20.1.1 | Columnf10GCChassisIndex | read-only | current | A unique value for each card. It starts from 0 to 9 contiguously. |
| 1.3.6.1.4.1.4756.20.630.20.1.2 | Columnf10GCSlotIndex | read-only | current | A unique value for each card. It starts from 1 to 20 contiguously. |
| 1.3.6.1.4.1.4756.20.630.20.1.3 | Columnf10GCCardHWVer | read-only | current | 10GC card hardware version x.xxx |
| 1.3.6.1.4.1.4756.20.630.20.1.4 | Columnf10GCCardFWVer | read-only | current | 10GC card firmware version x.xxx |
| 1.3.6.1.4.1.4756.20.630.20.1.5 | Columnf10GCCardCPLDVer | read-only | current | 10GC card CPLD version x.xxx |
| 1.3.6.1.4.1.4756.20.630.20.1.6 | Columnf10GCCardFPGAVer | read-only | current | 10GC card FPGA version x.xxx |
| 1.3.6.1.4.1.4756.20.630.20.1.7 | Columnf10GCPortReset | read-write | current | 10GC card system status: 0:Off 1:Trigger |
| 1.3.6.1.4.1.4756.20.630.20.1.8 | Columnf10GCSetToDefault | read-write | current | 10GC card port set to default: 0:Off 1:Trigger |
| 1.3.6.1.4.1.4756.20.630.20.1.9 | Columnf10GCFxLink | read-only | current | 10GC card fiber link status. |
| 1.3.6.1.4.1.4756.20.630.20.1.10 | Columnf10GCFxSFP | read-only | current | 10GC card fiber socket status. |
| 1.3.6.1.4.1.4756.20.630.20.1.11 | Columnf10GCFxFiberTxFault | read-only | current | 10GC card fiber Tx Fault status. |
| 1.3.6.1.4.1.4756.20.630.20.1.12 | Columnf10GCFxDDStatus | read-only | current | 10GC card fiber Digital Diagnostic status. |
| 1.3.6.1.4.1.4756.20.630.20.1.13 | Columnf10GCFxPortActive | read-write | current | 10GC card fiber port active: 0:Disable 1:Enable |
| 1.3.6.1.4.1.4756.20.630.20.1.14 | Columnf10GCFxLBT | read-write | current | 10GC card fiber port Loopback Test function: 0:Disable 1:Enable NOTE: The loopback function of 10GBase-R and 10GBase-T CAN NOT be activated at the same time. |
| 1.3.6.1.4.1.4756.20.630.20.1.15 | Columnf10GCFxFFA | read-write | current | 10GC card fiber fault alert: 0:Disable 1:Enable |
| 1.3.6.1.4.1.4756.20.630.20.1.16 | Columnf10GCFxALS | read-write | current | 10GC card fiber Automatically Laser Shutdown: 0:Disable 1:Enable |
| 1.3.6.1.4.1.4756.20.630.20.1.17 | Columnf10GCFxLFP | read-write | current | 10GC card fiber Link Fault Pass-Through: 0:Disable 1:Enable |
| 1.3.6.1.4.1.4756.20.630.20.1.18 | Columnf10GCUtpLink | read-only | current | 10GC card UTP Link status. |
| 1.3.6.1.4.1.4756.20.630.20.1.19 | Columnf10GCUtpSpeed | read-only | current | 10GC card UTP link speed status. |
| 1.3.6.1.4.1.4756.20.630.20.1.20 | Columnf10GCUtpPortActive | read-write | current | 10GC card UTP Port Active: 0:Disable 1:Enable |
| 1.3.6.1.4.1.4756.20.630.20.1.21 | Columnf10GCUtpLBT | read-write | current | 10GC card UTP Loopback Test Function: 0:Disable 1:Enable NOTE: The loopback function of 10GBase-R and 10GBase-T CAN NOT be activated at the same time. |
| 1.3.6.1.4.1.4756.20.630.20.1.22 | Columnf10GCUtpAutoCfg | read-write | current | 10GC card UTP Auto-Negotiation setting: 0:Force 1:Auto |
| 1.3.6.1.4.1.4756.20.630.20.1.23 | Columnf10GCUtpSpeedCfg | read-write | current | 10GC card UTP Speed setting: 0:10GBase-T 1:1000Base-T 2:100Base-TX 3: |
| 1.3.6.1.4.1.4756.20.630.20.1.24 | Columnf10GCUtpSRM | read-write | current | 10GC card UTP Short Reach Mode (< 30m) setting: 0:Disable 1:Enable |
| 1.3.6.1.4.1.4756.20.630.20.1.25 | Columnf10GCDeviceTemp | read-only | current | 10GC card device temperature status. |
| 1.3.6.1.4.1.4756.20.630.20.1.26 | Columnf10GCDeviceCurrTemp | read-only | current | 10GC card device current temperature. |
| 1.3.6.1.4.1.4756.20.630.20.1.27 | Columnf10GCDeviceActive | read-write | current | 10GC card Fiber and UTP port active: 0:Disable 1:Enable |
| 1.3.6.1.4.1.4756.20.630.20.1.28 | Columnf10GCDeviceTempProt | read-write | current | 10GC card Thermal Protection setting: 0:80 degree C 1:90 degree C 2:100 degree C 3:110 degree C |
| 1.3.6.1.4.1.4756.20.630.20.1.29 | Columnf10GCDeviceTempAlarm | read-write | current | 10GC card Temperature Alarm setting: 0:Disable 1:Enable |
| 1.3.6.1.4.1.4756.20.630.20.1.30 | Columnf10GCDeviceFTFAlarm | read-write | current | 10GC card Fiber Tx Fault Alarm setting: 0:Disable 1:Enable |
| 1.3.6.1.4.1.4756.20.630.20.1.31 | Columnf10GCDeviceEEE | read-write | current | 10GC card Energy Efficient Ethernet setting: 0:Disable 1:Enable |
| 1.3.6.1.4.1.4756.20.630.20.1.32 | Columnf10GCDSSFPA | read-write | current | 10GC card DIP Switch Status Front Panel Active setting: 0:Disable 1:Enable |
| 1.3.6.1.4.1.4756.20.630.20.1.33 | Columnf10GCDSSFXLFP | read-only | current | 10GC card DIP Switch Fiber Link Fault Pass-Through status. |
| 1.3.6.1.4.1.4756.20.630.20.1.34 | Columnf10GCDSSUTPSRM | read-only | current | 10GC card DIP Switch UTP Short Reach Mode (< 30m) status. |
| 1.3.6.1.4.1.4756.20.630.20.1.35 | Columnf10GCDSSFXLBT | read-only | current | 10GC card DIP Switch Fiber Loopback Testing Function status. |
| 1.3.6.1.4.1.4756.20.630.20.1.36 | Columnf10GCDSSUTPLBT | read-only | current | 10GC card DIP Switch UTP Loopback Testing Function status. |
| 1.3.6.1.4.1.4756.20.630.20.1.37 | Columnf10GCDSSBERT | read-only | current | 10GC card DIP Switch BERT function status. |
| 1.3.6.1.4.1.4756.20.630.20.1.38 | Columnf10GCDSSEEE | read-only | current | 10GC card DIP Switch Energy Efficient Ethernet function status. |
| 1.3.6.1.4.1.4756.20.630.20.1.39 | Columnf10GCSFPPVenderName | read-only | current | 10GC card SFP Plus Vender Name. |
| 1.3.6.1.4.1.4756.20.630.20.1.40 | Columnf10GCSFPPPartNo | read-only | current | 10GC card SFP Plus Part Number. |
| 1.3.6.1.4.1.4756.20.630.20.1.41 | Columnf10GCSFPPFiberType | read-only | current | 10GC card SFP Plus Fiber Type: 0:Multi 1:Single 2:Unknown |
| 1.3.6.1.4.1.4756.20.630.20.1.42 | Columnf10GCSFPPWaveLength1 | read-only | current | 10GC card SFP Plus Wave Length 1. |
| 1.3.6.1.4.1.4756.20.630.20.1.43 | Columnf10GCSFPPWaveLength2 | read-only | current | 10GC card SFP Plus Wave Length 2. |
| 1.3.6.1.4.1.4756.20.630.20.1.44 | Columnf10GCSFPPLinkLength | read-only | current | 10GC card SFP Plus Link Length. |
| 1.3.6.1.4.1.4756.20.630.20.1.45 | Columnf10GCSFPPTxPower | read-only | current | 10GC card SFP Plus Transmit Power. |
| 1.3.6.1.4.1.4756.20.630.20.1.46 | Columnf10GCSFPPRxPower | read-only | current | 10GC card SFP Plus Receive Power. |
| 1.3.6.1.4.1.4756.20.630.20.1.47 | Columnf10GCSFPPRxSens | read-only | current | 10GC card SFP Plus Receive Sensitivity. |
| 1.3.6.1.4.1.4756.20.630.20.1.48 | Columnf10GCSFPPRxPwrMargin | read-only | current | 10GC card SFP Plus Receive Power Margin. |
| 1.3.6.1.4.1.4756.20.630.20.1.49 | Columnf10GCSFPPTemperature | read-only | current | 10GC card SFP Plus Temperature. |
| 1.3.6.1.4.1.4756.20.630.20.1.50 | Columnf10GCSFPPSupplyVoltage | read-only | current | 10GC card SFP Plus Supply Voltage. |
| 1.3.6.1.4.1.4756.20.630.20.1.51 | Columnf10GCSFPPTxLaserBias | read-only | current | 10GC card SFP Plus Supply Voltage. |
| 1.3.6.1.4.1.4756.20.640 | NodefOADMCards | |||
| 1.3.6.1.4.1.4756.20.640.20 | TablefOADMTable | not-accessible | current | A list of local FRM220-OADM Serial cards entries. The number of entries is fOADM-No-L. |
| 1.3.6.1.4.1.4756.20.640.20.1 | RowfOADMEntry | not-accessible | current | An entry containing management information applicable to a particular local FRM220-OADM series card. |
| 1.3.6.1.4.1.4756.20.640.20.1.1 | ColumnfOADMChassisIndex | read-only | current | A unique value for each card. It starts from 0 to 9 contiguously. |
| 1.3.6.1.4.1.4756.20.640.20.1.2 | ColumnfOADMSlotIndex | read-only | current | A unique value for each card. It starts from 1 to 20 contiguously. |
| 1.3.6.1.4.1.4756.20.640.20.1.3 | ColumnfOADMCardHWVer | read-only | current | FRM220-OADM Serial cards hardware version x.xxx |
| 1.3.6.1.4.1.4756.20.640.20.1.4 | ColumnfOADMCardFWVer | read-only | current | FRM220-OADM Serial cards firmware version x.xxx |
| 1.3.6.1.4.1.4756.20.640.20.1.5 | ColumnfOADMCardCPLDVer | read-only | current | FRM220-OADM Serial cards CPLD version x.xxx |
| 1.3.6.1.4.1.4756.20.640.20.1.6 | ColumnfOADMCardFPGAVer | read-only | current | FRM220-OADM Serial cards FPGA version x.xxx |
| 1.3.6.1.4.1.4756.20.640.20.1.7 | ColumnfOADMCardModel | read-only | current | The OADM Serial cards Model type as below: 1:FRM220-OADM-61 2:FRM220-OADM-59 3:FRM220-OADM-57 4:FRM220-OADM-55 5:FRM220-OADM-53 6:FRM220-OADM-51 7:FRM220-OADM-… |
| 1.3.6.1.4.1.4756.20.640.20.1.8 | ColumnfOADMCardEastWaveLength1 | read-only | current | FRM220-OADM Serial cards EAST Wave Length 1. |
| 1.3.6.1.4.1.4756.20.640.20.1.9 | ColumnfOADMCardEastWaveLength2 | read-only | current | FRM220-OADM Serial cards EAST Wave Length 2. |
| 1.3.6.1.4.1.4756.20.640.20.1.10 | ColumnfOADMCardWestWaveLength1 | read-only | current | FRM220-OADM Serial cards WEST Wave Length 1. |
| 1.3.6.1.4.1.4756.20.640.20.1.11 | ColumnfOADMCardWestWaveLength2 | read-only | current | FRM220-OADM Serial cards WEST Wave Length 2. |
| 1.3.6.1.4.1.4756.20.650 | NodefDWDMCards | |||
| 1.3.6.1.4.1.4756.20.650.20 | TablefDWDMTable | not-accessible | current | A list of local FRM220-DWDM Serial cards entries. The number of entries is fDWDM-No-L. |
| 1.3.6.1.4.1.4756.20.650.20.1 | RowfDWDMEntry | not-accessible | current | An entry containing management information applicable to a particular local FRM220-DWDM series card. |
| 1.3.6.1.4.1.4756.20.650.20.1.1 | ColumnfDWDMChassisIndex | read-only | current | A unique value for each card. It starts from 0 to 9 contiguously. |
| 1.3.6.1.4.1.4756.20.650.20.1.2 | ColumnfDWDMSlotIndex | read-only | current | A unique value for each card. It starts from 1 to 20 contiguously. |
| 1.3.6.1.4.1.4756.20.650.20.1.3 | ColumnfDWDMCardHWVer | read-only | current | FRM220-DWDM Serial cards hardware version x.xxx |
| 1.3.6.1.4.1.4756.20.650.20.1.4 | ColumnfDWDMCardFWVer | read-only | current | FRM220-DWDM Serial cards firmware version x.xxx |
| 1.3.6.1.4.1.4756.20.650.20.1.5 | ColumnfDWDMCardCPLDVer | read-only | current | FRM220-DWDM Serial cards CPLD version x.xxx |
| 1.3.6.1.4.1.4756.20.650.20.1.6 | ColumnfDWDMCardFPGAVer | read-only | current | FRM220-DWDM Serial cards FPGA version x.xxx |
| 1.3.6.1.4.1.4756.20.650.20.1.7 | ColumnfDWDMCardModel | read-only | current | The DWDM Serial cards Model type as below: 1:FRM220-DWMD401-C21-C24 1:FRM220-DWMD801-C21-C28 |
| 1.3.6.1.4.1.4756.20.650.20.1.8 | ColumnfDWDMCardC21WaveLength | read-only | current | FRM220-DWDM Serial cards C Band: Frequency: 192.1 THz Center Wave Length: 1560.61 nm |
| 1.3.6.1.4.1.4756.20.650.20.1.9 | ColumnfDWDMCardC22WaveLength | read-only | current | FRM220-DWDM Serial cards C Band: Frequency: 192.2 THz Center Wave Length: 1559.79 nm |
| 1.3.6.1.4.1.4756.20.650.20.1.10 | ColumnfDWDMCardC23WaveLength | read-only | current | FRM220-DWDM Serial cards C Band: Frequency: 192.3 THz Center Wave Length: 1558.98 nm |
| 1.3.6.1.4.1.4756.20.650.20.1.11 | ColumnfDWDMCardC24WaveLength | read-only | current | FRM220-DWDM Serial cards C Band: Frequency: 192.4 THz Center Wave Length: 1558.17 nm |
| 1.3.6.1.4.1.4756.20.650.20.1.12 | ColumnfDWDMCardC25WaveLength | read-only | current | FRM220-DWDM Serial cards C Band: Frequency: 192.5 THz Center Wave Length: 1557.36 nm |
| 1.3.6.1.4.1.4756.20.650.20.1.13 | ColumnfDWDMCardC26WaveLength | read-only | current | FRM220-DWDM Serial cards C Band: Frequency: 192.6 THz Center Wave Length: 1556.55 nm |
| 1.3.6.1.4.1.4756.20.650.20.1.14 | ColumnfDWDMCardC27WaveLength | read-only | current | FRM220-DWDM Serial cards C Band: Frequency: 192.7 THz Center Wave Length: 1555.75 nm |
| 1.3.6.1.4.1.4756.20.650.20.1.15 | ColumnfDWDMCardC28WaveLength | read-only | current | FRM220-DWDM Serial cards C Band: Frequency: 192.8 THz Center Wave Length: 1554.94 nm |
| 1.3.6.1.4.1.4756.20.660 | NodefCCFLocalCards | |||
| 1.3.6.1.4.1.4756.20.660.20 | TablefCCFLocalTable | not-accessible | current | A list of local FRM220-CCF Serial cards entries. The number of entries is fCCF-No-L. |
| 1.3.6.1.4.1.4756.20.660.20.1 | RowfCCFLocalEntry | not-accessible | current | An entry containing management information applicable to a particular local FRM220-CCF series card. |
| 1.3.6.1.4.1.4756.20.660.20.1.1 | ColumnfCCFChassisIndexLocal | read-only | current | A unique value for each card. It starts from 0 to 9 contiguously. |
| 1.3.6.1.4.1.4756.20.660.20.1.2 | ColumnfCCFSlotIndexLocal | read-only | current | A unique value for each card. It starts from 1 to 20 contiguously. |
| 1.3.6.1.4.1.4756.20.660.20.1.3 | ColumnfCCFCardHWVerLocal | read-only | current | FRM220-CCF Serial cards hardware version x.xxx |
| 1.3.6.1.4.1.4756.20.660.20.1.4 | ColumnfCCFCardFWVerLocal | read-only | current | FRM220-CCF Serial cards firmware version x.xxx |
| 1.3.6.1.4.1.4756.20.660.20.1.5 | ColumnfCCFCardCPLDVerLocal | read-only | current | FRM220-CCF Serial cards CPLD version x.xxx |
| 1.3.6.1.4.1.4756.20.660.20.1.6 | ColumnfCCFCardFPGAVerLocal | read-only | current | FRM220-CCF Serial cards FPGA version x.xxx |
| 1.3.6.1.4.1.4756.20.660.20.1.7 | ColumnfCCFCardModelLocal | read-only | current | The CCF Serial cards Model type as below: 0:FRM220-CCF20 1:FRM220-CCF40 8:IFC-CCF20-HP 9:IFC-CCF40-HP |
| 1.3.6.1.4.1.4756.20.660.20.1.8 | ColumnfCCFPortResetLocal | read-only | current | CCF card Port Reset feature: 0:Inactive 1:Active |
| 1.3.6.1.4.1.4756.20.660.20.1.9 | ColumnfCCFSetToDefaultLocal | read-only | current | CCF card Set To Default feature: 0:Inactive 1:Active |
| 1.3.6.1.4.1.4756.20.660.20.1.10 | ColumnfCCFSFPExistLocal | read-only | current | FRM220-CCF Serial cards SFP Exist Information. |
| 1.3.6.1.4.1.4756.20.660.20.1.11 | ColumnfCCFSFPTypeLocal | read-only | current | FRM220-CCF Serial cards SFP Type Information. |
| 1.3.6.1.4.1.4756.20.660.20.1.12 | ColumnfCCFSFPTxFailureLocal | read-only | current | FRM220-CCF Serial cards SFP Tx Failure Information. |
| 1.3.6.1.4.1.4756.20.660.20.1.13 | ColumnfCCFSFPLinkLocal | read-only | current | FRM220-CCF Serial cards SFP Link Information. |
| 1.3.6.1.4.1.4756.20.660.20.1.14 | ColumnfCCFSFPSyncLocal | read-only | current | FRM220-CCF Serial cards SFP Sync Information. |
| 1.3.6.1.4.1.4756.20.660.20.1.15 | ColumnfCCFSFPLoopBackLocal | read-only | current | FRM220-CCF Serial cards SFP Loopback Information. |
| 1.3.6.1.4.1.4756.20.660.20.1.16 | ColumnfCCFSFPPortActiveLocal | read-write | current | FRM220-CCF Serial cards Port Active: 0:disable 1:enable |
| 1.3.6.1.4.1.4756.20.660.20.1.17 | ColumnfCCFSFPALSLocal | read-write | current | FRM220-CCF Serial cards Automatic Laser Shutdown (ALS): 0:disable 1:enable |
| 1.3.6.1.4.1.4756.20.660.20.1.18 | ColumnfCCFSFPTBLLocal | read-write | current | FRM220-CCF Serial cards Loopback Test Function: 0:Disable 1:LLB 2:RLB 3:RRLB |
| 1.3.6.1.4.1.4756.20.660.20.1.19 | ColumnfCCFDeviceAlarmLocal | read-only | current | FRM220-CCF Serial cards Alarm Status. |
| 1.3.6.1.4.1.4756.20.660.20.1.20 | ColumnfCCFDeviceActiveLocal | read-write | current | FRM220-CCF Serial cards Device Active: 0:Disable 1:Enable |
| 1.3.6.1.4.1.4756.20.660.20.1.21 | ColumnfCCFDeviceDebounceLocal | read-write | current | FRM220-CCF Serial cards Input Debounce: 0:Disable 1:Enable |
| 1.3.6.1.4.1.4756.20.660.20.1.22 | ColumnfCCFDeviceLinkAlarmLocal | read-write | current | FRM220-CCF Serial cards Link Alarm setting: 0:Disable 1:Enable |
| 1.3.6.1.4.1.4756.20.660.20.1.23 | ColumnfCCFSFPVenderNameLocal | read-only | current | FRM220-CCF Serial cards SFP Vender Name. |
| 1.3.6.1.4.1.4756.20.660.20.1.24 | ColumnfCCFSFPPartNoLocal | read-only | current | FRM220-CCF Serial cards SFP Part Number. |
| 1.3.6.1.4.1.4756.20.660.20.1.25 | ColumnfCCFSFPFiberTypeLocal | read-only | current | FRM220-CCF Serial cards SFP Fiber Type: 0:Multi 1:Single 2:Unknown |
| 1.3.6.1.4.1.4756.20.660.20.1.26 | ColumnfCCFSFPWaveLength1Local | read-only | current | FRM220-CCF Serial cards SFP Transmitter Wave Length. |
| 1.3.6.1.4.1.4756.20.660.20.1.27 | ColumnfCCFSFPWaveLength2Local | read-only | current | FRM220-CCF Serial cards SFP Receiver Wave Length. |
| 1.3.6.1.4.1.4756.20.660.20.1.28 | ColumnfCCFSFPLinkLengthLocal | read-only | current | FRM220-CCF Serial cards SFP Link Length. |
| 1.3.6.1.4.1.4756.20.660.20.1.29 | ColumnfCCFSFPTxPowerLocal | read-only | current | FRM220-CCF Serial cards SFP Tx Power. |
| 1.3.6.1.4.1.4756.20.660.20.1.30 | ColumnfCCFSFPRxPowerLocal | read-only | current | FRM220-CCF Serial cards SFP Rx Power. |
| 1.3.6.1.4.1.4756.20.660.20.1.31 | ColumnfCCFSFPRxSensLocal | read-only | current | FRM220-CCF Serial cards SFP Rx Sensitivity. |
| 1.3.6.1.4.1.4756.20.660.20.1.32 | ColumnfCCFSFPRxPwrMarginLocal | read-only | current | FRM220-CCF Serial cards SFP Rx Power Margin. |
| 1.3.6.1.4.1.4756.20.660.20.1.33 | ColumnfCCFSFPTemperatureLocal | read-only | current | FRM220-CCF Serial cards SFP Temperature. |
| 1.3.6.1.4.1.4756.20.660.20.1.34 | ColumnfCCFSFPSupplyVoltageLocal | read-only | current | FRM220-CCF Serial cards SFP Supper Voltage. |
| 1.3.6.1.4.1.4756.20.660.20.1.35 | ColumnfCCFSFPTxLaserBiasLocal | read-only | current | FRM220-CCF Serial cards SFP Tx Laser Bias. |
| 1.3.6.1.4.1.4756.20.660.20.1.36 | ColumnfCCFChannel1InputLocal | read-only | current | FRM220-CCF Serial cards Channel 1 Input. |
| 1.3.6.1.4.1.4756.20.660.20.1.37 | ColumnfCCFChannel1OutputLocal | read-only | current | FRM220-CCF Serial cards Channel 1 Output. |
| 1.3.6.1.4.1.4756.20.660.20.1.38 | ColumnfCCFChannel1RelayLocal | read-write | current | FRM220-CCF Serial cards Channel 1 Relay Control: 0:By Input 1:Force Off 2:Force On 3:Fiber Sync Loss Off 4:Fiber Sync Loss On 5:Non Support |
| 1.3.6.1.4.1.4756.20.660.20.1.39 | ColumnfCCFChannel2InputLocal | read-only | current | FRM220-CCF Serial cards Channel 2 Input. |
| 1.3.6.1.4.1.4756.20.660.20.1.40 | ColumnfCCFChannel2OutputLocal | read-only | current | FRM220-CCF Serial cards Channel 2 Output. |
| 1.3.6.1.4.1.4756.20.660.20.1.41 | ColumnfCCFChannel2RelayLocal | read-write | current | FRM220-CCF Serial cards Channel 2 Relay Control: 0:By Input 1:Force Off 2:Force On 3:Fiber Sync Loss Off 4:Fiber Sync Loss On 5:Non Support |
| 1.3.6.1.4.1.4756.20.660.20.1.42 | ColumnfCCFChannel3InputLocal | read-only | current | FRM220-CCF Serial cards Channel 3 Input. |
| 1.3.6.1.4.1.4756.20.660.20.1.43 | ColumnfCCFChannel3OutputLocal | read-only | current | FRM220-CCF Serial cards Channel 3 Output. |
| 1.3.6.1.4.1.4756.20.660.20.1.44 | ColumnfCCFChannel3RelayLocal | read-write | current | FRM220-CCF Serial cards Channel 3 Relay Control: 0:By Input 1:Force Off 2:Force On 3:Fiber Sync Loss Off 4:Fiber Sync Loss On 5:Non Support |
| 1.3.6.1.4.1.4756.20.660.20.1.45 | ColumnfCCFChannel4InputLocal | read-only | current | FRM220-CCF Serial cards Channel 4 Input. |
| 1.3.6.1.4.1.4756.20.660.20.1.46 | ColumnfCCFChannel4OutputLocal | read-only | current | FRM220-CCF Serial cards Channel 4 Output. |
| 1.3.6.1.4.1.4756.20.660.20.1.47 | ColumnfCCFChannel4RelayLocal | read-write | current | FRM220-CCF Serial cards Channel 4 Relay Control: 0:By Input 1:Force Off 2:Force On 3:Fiber Sync Loss Off 4:Fiber Sync Loss On 5:Non Support |
| 1.3.6.1.4.1.4756.20.661 | NodefCCFRemoteCards | |||
| 1.3.6.1.4.1.4756.20.661.20 | TablefCCFRemoteTable | not-accessible | current | A list of local FRM220-CCF Serial cards entries. The number of entries is fCCF-No-R. |
| 1.3.6.1.4.1.4756.20.661.20.1 | RowfCCFRemoteEntry | not-accessible | current | An entry containing management information applicable to a particular local FRM220-CCF series card. |
| 1.3.6.1.4.1.4756.20.661.20.1.1 | ColumnfCCFChassisIndexRemote | read-only | current | A unique value for each card. It starts from 0 to 9 contiguously. |
| 1.3.6.1.4.1.4756.20.661.20.1.2 | ColumnfCCFSlotIndexRemote | read-only | current | A unique value for each card. It starts from 1 to 20 contiguously. |
| 1.3.6.1.4.1.4756.20.661.20.1.3 | ColumnfCCFCardHWVerRemote | read-only | current | FRM220-CCF Serial cards hardware version x.xxx |
| 1.3.6.1.4.1.4756.20.661.20.1.4 | ColumnfCCFCardFWVerRemote | read-only | current | FRM220-CCF Serial cards firmware version x.xxx |
| 1.3.6.1.4.1.4756.20.661.20.1.5 | ColumnfCCFCardCPLDVerRemote | read-only | current | FRM220-CCF Serial cards CPLD version x.xxx |
| 1.3.6.1.4.1.4756.20.661.20.1.6 | ColumnfCCFCardFPGAVerRemote | read-only | current | FRM220-CCF Serial cards FPGA version x.xxx |
| 1.3.6.1.4.1.4756.20.661.20.1.7 | ColumnfCCFCardModelRemote | read-only | current | The CCF Serial cards Model type as below: 0:FRM220-CCF20 1:FRM220-CCF40 8:IFC-CCF20-HP 9:IFC-CCF40-HP |
| 1.3.6.1.4.1.4756.20.661.20.1.8 | ColumnfCCFPortResetRemote | read-only | current | CCF card Port Reset feature: 0:Inactive 1:Active |
| 1.3.6.1.4.1.4756.20.661.20.1.9 | ColumnfCCFSetToDefaultRemote | read-only | current | CCF card Set To Default feature: 0:Inactive 1:Active |
| 1.3.6.1.4.1.4756.20.661.20.1.10 | ColumnfCCFSFPExistRemote | read-only | current | FRM220-CCF Serial cards SFP Exist Information. |
| 1.3.6.1.4.1.4756.20.661.20.1.11 | ColumnfCCFSFPTypeRemote | read-only | current | FRM220-CCF Serial cards SFP Type Information. |
| 1.3.6.1.4.1.4756.20.661.20.1.12 | ColumnfCCFSFPTxFailureRemote | read-only | current | FRM220-CCF Serial cards SFP Tx Failure Information. |
| 1.3.6.1.4.1.4756.20.661.20.1.13 | ColumnfCCFSFPLinkRemote | read-only | current | FRM220-CCF Serial cards SFP Link Information. |
| 1.3.6.1.4.1.4756.20.661.20.1.14 | ColumnfCCFSFPSyncRemote | read-only | current | FRM220-CCF Serial cards SFP Sync Information. |
| 1.3.6.1.4.1.4756.20.661.20.1.15 | ColumnfCCFSFPLoopBackRemote | read-only | current | FRM220-CCF Serial cards SFP Loopback Information. |
| 1.3.6.1.4.1.4756.20.661.20.1.16 | ColumnfCCFSFPPortActiveRemote | read-write | current | FRM220-CCF Serial cards Port Active: 0:disable 1:enable |
| 1.3.6.1.4.1.4756.20.661.20.1.17 | ColumnfCCFSFPALSRemote | read-write | current | FRM220-CCF Serial cards Auto Laser Shutdown (ALS): 0:disable 1:enable |
| 1.3.6.1.4.1.4756.20.661.20.1.18 | ColumnfCCFDeviceAlarmRemote | read-only | current | FRM220-CCF Serial cards Alarm Status. |
| 1.3.6.1.4.1.4756.20.661.20.1.19 | ColumnfCCFDeviceActiveRemote | read-write | current | FRM220-CCF Serial cards Device Active: 0:Disable 1:Enable |
| 1.3.6.1.4.1.4756.20.661.20.1.20 | ColumnfCCFDeviceDebounceRemote | read-write | current | FRM220-CCF Serial cards Input Debounce: 0:Disable 1:Enable |
| 1.3.6.1.4.1.4756.20.661.20.1.21 | ColumnfCCFSFPVenderNameRemote | read-only | current | FRM220-CCF Serial cards SFP Vender Name. |
| 1.3.6.1.4.1.4756.20.661.20.1.22 | ColumnfCCFSFPPartNoRemote | read-only | current | FRM220-CCF Serial cards SFP Part Number. |
| 1.3.6.1.4.1.4756.20.661.20.1.23 | ColumnfCCFSFPFiberTypeRemote | read-only | current | FRM220-CCF Serial cards SFP Fiber Type: 0:Multi 1:Single 2:Unknown |
| 1.3.6.1.4.1.4756.20.661.20.1.24 | ColumnfCCFSFPWaveLength1Remote | read-only | current | FRM220-CCF Serial cards SFP Transmitter Wave Length. |
| 1.3.6.1.4.1.4756.20.661.20.1.25 | ColumnfCCFSFPWaveLength2Remote | read-only | current | FRM220-CCF Serial cards SFP Receiver Wave Length. |
| 1.3.6.1.4.1.4756.20.661.20.1.26 | ColumnfCCFSFPLinkLengthRemote | read-only | current | FRM220-CCF Serial cards SFP Link Length. |
| 1.3.6.1.4.1.4756.20.661.20.1.27 | ColumnfCCFSFPTxPowerRemote | read-only | current | FRM220-CCF Serial cards SFP Tx Power. |
| 1.3.6.1.4.1.4756.20.661.20.1.28 | ColumnfCCFSFPRxPowerRemote | read-only | current | FRM220-CCF Serial cards SFP Rx Power. |
| 1.3.6.1.4.1.4756.20.661.20.1.29 | ColumnfCCFSFPRxSensRemote | read-only | current | FRM220-CCF Serial cards SFP Rx Sensitivity. |
| 1.3.6.1.4.1.4756.20.661.20.1.30 | ColumnfCCFSFPRxPwrMarginRemote | read-only | current | FRM220-CCF Serial cards SFP Rx Power Margin. |
| 1.3.6.1.4.1.4756.20.661.20.1.31 | ColumnfCCFSFPTemperatureRemote | read-only | current | FRM220-CCF Serial cards SFP Temperature. |
| 1.3.6.1.4.1.4756.20.661.20.1.32 | ColumnfCCFSFPSupplyVoltageRemote | read-only | current | FRM220-CCF Serial cards SFP Supper Voltage. |
| 1.3.6.1.4.1.4756.20.661.20.1.33 | ColumnfCCFSFPTxLaserBiasRemote | read-only | current | FRM220-CCF Serial cards SFP Tx Laser Bias. |
| 1.3.6.1.4.1.4756.20.661.20.1.34 | ColumnfCCFChannel1InputRemote | read-only | current | FRM220-CCF Serial cards Channel 1 Input. |
| 1.3.6.1.4.1.4756.20.661.20.1.35 | ColumnfCCFChannel1OutputRemote | read-only | current | FRM220-CCF Serial cards Channel 1 Output. |
| 1.3.6.1.4.1.4756.20.661.20.1.36 | ColumnfCCFChannel1RelayRemote | read-write | current | FRM220-CCF Serial cards Channel 1 Relay Control: 0:By Input 1:Force Off 2:Force On 3:Fiber Sync Loss Off 4:Fiber Sync Loss On 5:Non Support |
| 1.3.6.1.4.1.4756.20.661.20.1.37 | ColumnfCCFChannel2InputRemote | read-only | current | FRM220-CCF Serial cards Channel 2 Input. |
| 1.3.6.1.4.1.4756.20.661.20.1.38 | ColumnfCCFChannel2OutputRemote | read-only | current | FRM220-CCF Serial cards Channel 2 Output. |
| 1.3.6.1.4.1.4756.20.661.20.1.39 | ColumnfCCFChannel2RelayRemote | read-write | current | FRM220-CCF Serial cards Channel 2 Relay Control: 0:By Input 1:Force Off 2:Force On 3:Fiber Sync Loss Off 4:Fiber Sync Loss On 5:Non Support |
| 1.3.6.1.4.1.4756.20.661.20.1.40 | ColumnfCCFChannel3InputRemote | read-only | current | FRM220-CCF Serial cards Channel 3 Input. |
| 1.3.6.1.4.1.4756.20.661.20.1.41 | ColumnfCCFChannel3OutputRemote | read-only | current | FRM220-CCF Serial cards Channel 3 Output. |
| 1.3.6.1.4.1.4756.20.661.20.1.42 | ColumnfCCFChannel3RelayRemote | read-write | current | FRM220-CCF Serial cards Channel 3 Relay Control: 0:By Input 1:Force Off 2:Force On 3:Fiber Sync Loss Off 4:Fiber Sync Loss On 5:Non Support |
| 1.3.6.1.4.1.4756.20.661.20.1.43 | ColumnfCCFChannel4InputRemote | read-only | current | FRM220-CCF Serial cards Channel 4 Input. |
| 1.3.6.1.4.1.4756.20.661.20.1.44 | ColumnfCCFChannel4OutputRemote | read-only | current | FRM220-CCF Serial cards Channel 4 Output. |
| 1.3.6.1.4.1.4756.20.661.20.1.45 | ColumnfCCFChannel4RelayRemote | read-write | current | FRM220-CCF Serial cards Channel 4 Relay Control: 0:By Input 1:Force Off 2:Force On 3:Fiber Sync Loss Off 4:Fiber Sync Loss On 5:Non Support |
| 1.3.6.1.4.1.4756.20.661.20.1.46 | ColumnfCCFDSSChannel1ThresholdRemote | read-only | current | FRM220-CCF Serial cards Channel 1 Thresold. |
| 1.3.6.1.4.1.4756.20.661.20.1.47 | ColumnfCCFDSSChannel2ThresholdRemote | read-only | current | FRM220-CCF Serial cards Channel 2 Thresold. |
| 1.3.6.1.4.1.4756.20.661.20.1.48 | ColumnfCCFDSSChannel3ThresholdRemote | read-only | current | FRM220-CCF Serial cards Channel 3 Thresold. |
| 1.3.6.1.4.1.4756.20.661.20.1.49 | ColumnfCCFDSSChannel4ThresholdRemote | read-only | current | FRM220-CCF Serial cards Channel 4 Thresold. |
| 1.3.6.1.4.1.4756.20.670 | Nodef4G3RCards | |||
| 1.3.6.1.4.1.4756.20.670.20 | Tablef4G3RTable | not-accessible | current | A list of local FRM220-4G-3R card entries. The number of entries is f4G3R-No-L. |
| 1.3.6.1.4.1.4756.20.670.20.1 | Rowf4G3REntry | not-accessible | current | An entry containing management information applicable to a particular local FRM220-4G-3R card. |
| 1.3.6.1.4.1.4756.20.670.20.1.1 | Columnf4G3RChassisIndex | read-only | current | A unique value for each local card. It is the chassis location number. |
| 1.3.6.1.4.1.4756.20.670.20.1.2 | Columnf4G3RSlotIndex | read-only | current | A unique value for each local card. It is the slot location number. |
| 1.3.6.1.4.1.4756.20.670.20.1.3 | Columnf4G3RCardHWVer | read-only | current | Local FRM220-4G-3R card hardware version x.xxx |
| 1.3.6.1.4.1.4756.20.670.20.1.4 | Columnf4G3RCardFWVer | read-only | current | Local FRM220-4G-3R card firmware version x.xxx |
| 1.3.6.1.4.1.4756.20.670.20.1.5 | Columnf4G3RCardCPLDVer | read-only | current | Local FRM220-4G-3R card CPLD version x.xxx |
| 1.3.6.1.4.1.4756.20.670.20.1.6 | Columnf4G3RCardFPGAVer | read-only | current | Local FRM220-4G-3R card FPGA version x.xxx |
| 1.3.6.1.4.1.4756.20.670.20.1.7 | Columnf4G3RFx1Link | read-only | current | Local FRM220-4G-3R card Fiber1 link status: 0:Down 1:Up |
| 1.3.6.1.4.1.4756.20.670.20.1.8 | Columnf4G3RFx2Link | read-only | current | Local FRM220-4G-3R card Fiber2 link status: 0:Down 1:Up |
| 1.3.6.1.4.1.4756.20.670.20.1.9 | Columnf4G3RFx3Link | read-only | current | Local FRM220-4G-3R card Fiber3 link status: 0:Down 1:Up |
| 1.3.6.1.4.1.4756.20.670.20.1.10 | Columnf4G3RFx4Link | read-only | current | Local FRM220-4G-3R card Fiber4 link status: 0:Down 1:Up |
| 1.3.6.1.4.1.4756.20.670.20.1.11 | Columnf4G3RFx1CDRLocked | read-only | current | Local FRM220-4G-3R card Fiber1 CRD Locked: 0:Not Locked 1:Locked |
| 1.3.6.1.4.1.4756.20.670.20.1.12 | Columnf4G3RFx2CDRLocked | read-only | current | Local FRM220-4G-3R card Fiber2 CRD Locked: 0:Not Locked 1:Locked |
| 1.3.6.1.4.1.4756.20.670.20.1.13 | Columnf4G3RFx3CDRLocked | read-only | current | Local FRM220-4G-3R card Fiber3 CRD Locked: 0:Not Locked 1:Locked |
| 1.3.6.1.4.1.4756.20.670.20.1.14 | Columnf4G3RFx4CDRLocked | read-only | current | Local FRM220-4G-3R card Fiber4 CRD Locked: 0:Not Locked 1:Locked |
| 1.3.6.1.4.1.4756.20.670.20.1.15 | Columnf4G3RFx1TxFault | read-only | current | Local FRM220-4G-3R card Fiber1 Tx Fault: 0:Normal 1:Failure |
| 1.3.6.1.4.1.4756.20.670.20.1.16 | Columnf4G3RFx2TxFault | read-only | current | Local FRM220-4G-3R card Fiber2 Tx Fault: 0:Normal 1:Failure |
| 1.3.6.1.4.1.4756.20.670.20.1.17 | Columnf4G3RFx3TxFault | read-only | current | Local FRM220-4G-3R card Fiber3 Tx Fault: 0:Normal 1:Failure |
| 1.3.6.1.4.1.4756.20.670.20.1.18 | Columnf4G3RFx4TxFault | read-only | current | Local FRM220-4G-3R card Fiber4 Tx Fault: 0:Normal 1:Failure |
| 1.3.6.1.4.1.4756.20.670.20.1.19 | Columnf4G3RFx1DD | read-only | current | Local FRM220-4G-3R card fiber1 Digital Diagnostic function: 0:No 1:Yes |
| 1.3.6.1.4.1.4756.20.670.20.1.20 | Columnf4G3RFx2DD | read-only | current | Local FRM220-4G-3R card fiber2 Digital Diagnostic function: 0:No 1:Yes |
| 1.3.6.1.4.1.4756.20.670.20.1.21 | Columnf4G3RFx3DD | read-only | current | Local FRM220-4G-3R card fiber3 Digital Diagnostic function: 0:No 1:Yes |
| 1.3.6.1.4.1.4756.20.670.20.1.22 | Columnf4G3RFx4DD | read-only | current | Local FRM220-4G-3R card fiber4 Digital Diagnostic function: 0:No 1:Yes |
| 1.3.6.1.4.1.4756.20.670.20.1.23 | Columnf4G3RFx1DDStatus | read-only | current | Local FRM220-4G-3R card fiber1 D/D information: Status Support |
| 1.3.6.1.4.1.4756.20.670.20.1.24 | Columnf4G3RFx2DDStatus | read-only | current | Local FRM220-4G-3R card fiber2 D/D information: Status Support |
| 1.3.6.1.4.1.4756.20.670.20.1.25 | Columnf4G3RFx3DDStatus | read-only | current | Local FRM220-4G-3R card fiber3 D/D information: Status Support |
| 1.3.6.1.4.1.4756.20.670.20.1.26 | Columnf4G3RFx4DDStatus | read-only | current | Local FRM220-4G-3R card fiber4 D/D information: Status Support |
| 1.3.6.1.4.1.4756.20.670.20.1.27 | Columnf4G3RDeviceActive | read-write | current | Local FRM220-4G-3R card active: 0:Inactive 1:Active |
| 1.3.6.1.4.1.4756.20.670.20.1.28 | Columnf4G3RPortReset | read-write | current | Force local FRM220-4G-3R card to reset mode: 0:Off 1:Action |
| 1.3.6.1.4.1.4756.20.670.20.1.29 | Columnf4G3RSetDefault | read-write | current | Local FRM220-4G-3R card set to default : 0:Off 1:Action |
| 1.3.6.1.4.1.4756.20.670.20.1.30 | Columnf4G3RWorkMode | read-write | current | Local FRM220-4G-3R card Work Mode : 0:Protection 1:Dual Channel |
| 1.3.6.1.4.1.4756.20.670.20.1.31 | Columnf4G3RFx1Lbsetting | read-write | current | Local FRM220-4G-3R card Fiber1 Loopback: 0:Disable 1:Enable |
| 1.3.6.1.4.1.4756.20.670.20.1.32 | Columnf4G3RFx2Lbsetting | read-write | current | Local FRM220-4G-3R card Fiber2 Loopback: 0:Disable 1:Enable |
| 1.3.6.1.4.1.4756.20.670.20.1.33 | Columnf4G3RFx3Lbsetting | read-write | current | Local FRM220-4G-3R card Fiber3 Loopback: 0:Disable 1:Enable |
| 1.3.6.1.4.1.4756.20.670.20.1.34 | Columnf4G3RFx4Lbsetting | read-write | current | Local FRM220-4G-3R card Fiber4 Loopback: 0:Disable 1:Enable |
| 1.3.6.1.4.1.4756.20.670.20.1.35 | Columnf4G3RFx1LFPT | read-write | current | Local FRM220-4G-3R card Fiber1 Link Fault Pass Through: 0:Disable 1:Enable |
| 1.3.6.1.4.1.4756.20.670.20.1.36 | Columnf4G3RFx2LFPT | read-write | current | Local FRM220-4G-3R card Fiber2 Link Fault Pass Through: 0:Disable 1:Enable |
| 1.3.6.1.4.1.4756.20.670.20.1.37 | Columnf4G3RFx3LFPT | read-write | current | Local FRM220-4G-3R card Fiber3 Link Fault Pass Through: 0:Disable 1:Enable |
| 1.3.6.1.4.1.4756.20.670.20.1.38 | Columnf4G3RFx4LFPT | read-write | current | Local FRM220-4G-3R card Fiber4 Link Fault Pass Through: 0:Disable 1:Enable |
| 1.3.6.1.4.1.4756.20.670.20.1.39 | Columnf4G3RFx1ALSMode | read-write | current | Local FRM220-4G-3R card Fiber1 Auto Laser Showdown: 0:Disable 1:Enable |
| 1.3.6.1.4.1.4756.20.670.20.1.40 | Columnf4G3RFx2ALSMode | read-write | current | Local FRM220-4G-3R card Fiber2 Auto Laser Showdown: 0:Disable 1:Enable |
| 1.3.6.1.4.1.4756.20.670.20.1.41 | Columnf4G3RFx3ALSMode | read-write | current | Local FRM220-4G-3R card Fiber3 Auto Laser Showdown: 0:Disable 1:Enable |
| 1.3.6.1.4.1.4756.20.670.20.1.42 | Columnf4G3RFx4ALSMode | read-write | current | Local FRM220-4G-3R card Fiber4 Auto Laser Showdown: 0:Disable 1:Enable |
| 1.3.6.1.4.1.4756.20.670.20.1.43 | Columnf4G3RFx1LinkAlarm | read-write | current | Local FRM220-4G-3R card Fx1 Link Alarm: 0:Disalbe 1:Enable |
| 1.3.6.1.4.1.4756.20.670.20.1.44 | Columnf4G3RFx2LinkAlarm | read-write | current | Local FRM220-4G-3R card Fx2 Link Alarm: 0:Disalbe 1:Enable |
| 1.3.6.1.4.1.4756.20.670.20.1.45 | Columnf4G3RFx3LinkAlarm | read-write | current | Local FRM220-4G-3R card Fx3 Link Alarm: 0:Disalbe 1:Enable |
| 1.3.6.1.4.1.4756.20.670.20.1.46 | Columnf4G3RFx4LinkAlarm | read-write | current | Local FRM220-4G-3R card Fx4 Link Alarm: 0:Disalbe 1:Enable |
| 1.3.6.1.4.1.4756.20.670.20.1.47 | Columnf4G3R3R2RMode | read-write | current | Local FRM220-4G-3R card 2R/3R Mode: 0:3R 1:2R |
| 1.3.6.1.4.1.4756.20.670.20.1.48 | Columnf4G3RWorkingPathStatus | read-only | current | Local FRM220-4G-3R card Workinng Path Status (Protection mode only): 0:Primary 1:Secondary |
| 1.3.6.1.4.1.4756.20.670.20.1.49 | Columnf4G3RWorkingPath | read-write | current | Local FRM220-4G-3R card Workinng Path(Protection mode only): 0:Auto-Revert 1:Non Revert 2:Primary 3:Secondary |
| 1.3.6.1.4.1.4756.20.670.20.1.50 | Columnf4G3RDataRatelStatus | read-only | current | Local FRM220-4G-3R card Data Rate 1 Status (3R Mode Only): |
| 1.3.6.1.4.1.4756.20.670.20.1.51 | Columnf4G3RDataRate2Status | read-only | current | Local FRM220-4G-3R card Data Rate 2 Status (3R Mode and Dual Channel Only): |
| 1.3.6.1.4.1.4756.20.670.20.1.52 | Columnf4G3RProtocol1 | read-only | current | Local FRM220-4G-3R card Protocol 1 (3R Mode Only): 0:Ethernet 1:SONET/SDH 2:Fiber Channel 3:CPRI 4:OBSAI 5:SDI/Other 6:Not Support |
| 1.3.6.1.4.1.4756.20.670.20.1.53 | Columnf4G3RRate1 | read-write | current | Local FRM220-4G-3R card Rate 1 (3R Mode Only): Ethernet 0: 1GE SONET/SDH 8: OC-48/STM-16 9: OC-24 10: OC-12/STM-4 Fiber Channel 16: 4GFC 17: 2GFC 18: 1GFC CPRI… |
| 1.3.6.1.4.1.4756.20.670.20.1.54 | Columnf4G3RProtocol2 | read-only | current | Local FRM220-4G-3R Protocol 2 (3R Mode and Dual Channel Only): 0:Ethernet 1:SONET/SDH 2:Fiber Channel 3:CPRI 4:OBSAI 6:None |
| 1.3.6.1.4.1.4756.20.670.20.1.55 | Columnf4G3RRate2 | read-write | current | Local FRM220-4G-3R card Rate 1 (3R Mode and Dual Channel Only): Ethernet 0: 1GE SONET/SDH 8: OC-48/STM-16 9:OC-24 10:OC-12/STM-4 Fiber Channel 16: 4GFC 17: 2GF… |
| 1.3.6.1.4.1.4756.20.670.20.1.56 | Columnf4G3RChannel1Active | read-write | current | Local FRM220-4G-3R card Channel 1 Active(Dual Channel only): 0:Disable 1:Enable |
| 1.3.6.1.4.1.4756.20.670.20.1.57 | Columnf4G3RChannel2Active | read-write | current | Local FRM220-4G-3R card Channel 2 Active(Dual Channel only): 0:Disable 1:Enable |
| 1.3.6.1.4.1.4756.20.670.20.1.58 | Columnf4G3RFx1DDVendor | read-only | current | Local FRM220-4G-3R card fiber1 D/D information: Vendor name |
| 1.3.6.1.4.1.4756.20.670.20.1.59 | Columnf4G3RFx1DDPartNo | read-only | current | Local FRM220-4G-3R card fiber1 D/D information: Vendor part number |
| 1.3.6.1.4.1.4756.20.670.20.1.60 | Columnf4G3RFx1DDVendorSN | read-only | current | Local FRM220-4G-3R card fiber1 D/D information: Vendor Serial Number |
| 1.3.6.1.4.1.4756.20.670.20.1.61 | Columnf4G3RFx1DDFiberType | read-only | current | Local FRM220-4G-3R card fiber1 D/D information: Fiber Type |
| 1.3.6.1.4.1.4756.20.670.20.1.62 | Columnf4G3RFx1DDWaveLen | read-only | current | Local FRM220-4G-3R card fiber1 D/D information: Wave length |
| 1.3.6.1.4.1.4756.20.670.20.1.63 | Columnf4G3RFx1DDWaveLen2 | read-only | current | Local FRM220-4G-3R card fiber1 D/D information: Wave length 2 |
| 1.3.6.1.4.1.4756.20.670.20.1.64 | Columnf4G3RFx1DDLinkLen | read-only | current | Local FRM220-4G-3R card fiber1 D/D information: Link length |
| 1.3.6.1.4.1.4756.20.670.20.1.65 | Columnf4G3RFx1DDLenUnit | read-only | current | Local FRM220-4G-3R card fiber1 D/D information: Length Unit |
| 1.3.6.1.4.1.4756.20.670.20.1.66 | Columnf4G3RFx1DDRxSens | read-only | current | Local FRM220-4G-3R card fiber1 D/D information: Rx Sensitivity |
| 1.3.6.1.4.1.4756.20.670.20.1.67 | Columnf4G3RFx1DDTxPWR | read-only | current | Local FRM220-4G-3R card fiber1 D/D information: Tx power |
| 1.3.6.1.4.1.4756.20.670.20.1.68 | Columnf4G3RFx1DDRxPWR | read-only | current | Local FRM220-4G-3R card fiber1 D/D information: Rx power |
| 1.3.6.1.4.1.4756.20.670.20.1.69 | Columnf4G3RFx1RxPowerStatus | read-only | current | Local FRM220-4G-3R card fiber1 Rx Power Status: 0:Normal 1:Warning 2:Alarm |
| 1.3.6.1.4.1.4756.20.670.20.1.70 | Columnf4G3RFx1DDTemp | read-only | current | Local FRM220-4G-3R card fiber1 D/D information: Temperature in degree C |
| 1.3.6.1.4.1.4756.20.670.20.1.71 | Columnf4G3RFx1DDPWRMargin | read-only | current | Local FRM220-4G-3R card fiber1 D/D information: Power margin |
| 1.3.6.1.4.1.4756.20.670.20.1.72 | Columnf4G3RFx2DDVendor | read-only | current | Local FRM220-4G-3R card fiber2 D/D information: Vendor name |
| 1.3.6.1.4.1.4756.20.670.20.1.73 | Columnf4G3RFx2DDPartNo | read-only | current | Local FRM220-4G-3R card fiber2 D/D information: Vendor part number |
| 1.3.6.1.4.1.4756.20.670.20.1.74 | Columnf4G3RFx2DDVendorSN | read-only | current | Local FRM220-4G-3R card fiber2 D/D information: Vendor Serial Number |
| 1.3.6.1.4.1.4756.20.670.20.1.75 | Columnf4G3RFx2DDFiberType | read-only | current | Local FRM220-4G-3R card fiber2 D/D information: Fiber Type |
| 1.3.6.1.4.1.4756.20.670.20.1.76 | Columnf4G3RFx2DDWaveLen | read-only | current | Local FRM220-4G-3R card fiber2 D/D information: Wave length |
| 1.3.6.1.4.1.4756.20.670.20.1.77 | Columnf4G3RFx2DDWaveLen2 | read-only | current | Local FRM220-4G-3R card fiber2 D/D information: Wave length 2 |
| 1.3.6.1.4.1.4756.20.670.20.1.78 | Columnf4G3RFx2DDLinkLen | read-only | current | Local FRM220-4G-3R card fiber2 D/D information: Link length |
| 1.3.6.1.4.1.4756.20.670.20.1.79 | Columnf4G3RFx2DDLenUnit | read-only | current | Local FRM220-4G-3R card fiber2 D/D information: Length Unit |
| 1.3.6.1.4.1.4756.20.670.20.1.80 | Columnf4G3RFx2DDRxSens | read-only | current | Local FRM220-4G-3R card fiber2 D/D information: Rx Sensitivity |
| 1.3.6.1.4.1.4756.20.670.20.1.81 | Columnf4G3RFx2DDTxPWR | read-only | current | Local FRM220-4G-3R card fiber2 D/D information: Tx power |
| 1.3.6.1.4.1.4756.20.670.20.1.82 | Columnf4G3RFx2DDRxPWR | read-only | current | Local FRM220-4G-3R card fiber2 D/D information: Rx power |
| 1.3.6.1.4.1.4756.20.670.20.1.83 | Columnf4G3RFx2RxPowerStatus | read-only | current | Local FRM220-4G-3R card fiber2 Rx Power Status: 0:Normal 1:Warning 2:Alarm |
| 1.3.6.1.4.1.4756.20.670.20.1.84 | Columnf4G3RFx2DDTemp | read-only | current | Local FRM220-4G-3R card fiber2 D/D information: Temperature in degree C |
| 1.3.6.1.4.1.4756.20.670.20.1.85 | Columnf4G3RFx2DDPWRMargin | read-only | current | Local FRM220-4G-3R card fiber2 D/D information: Power margin |
| 1.3.6.1.4.1.4756.20.670.20.1.86 | Columnf4G3RFx3DDVendor | read-only | current | Local FRM220-4G-3R card fiber3 D/D information: Vendor name |
| 1.3.6.1.4.1.4756.20.670.20.1.87 | Columnf4G3RFx3DDPartNo | read-only | current | Local FRM220-4G-3R card fiber3 D/D information: Vendor part number |
| 1.3.6.1.4.1.4756.20.670.20.1.88 | Columnf4G3RFx3DDVendorSN | read-only | current | Local FRM220-4G-3R card fiber3 D/D information: Vendor Serial Number |
| 1.3.6.1.4.1.4756.20.670.20.1.89 | Columnf4G3RFx3DDFiberType | read-only | current | Local FRM220-4G-3R card fiber3 D/D information: Fiber Type |
| 1.3.6.1.4.1.4756.20.670.20.1.90 | Columnf4G3RFx3DDWaveLen | read-only | current | Local FRM220-4G-3R card fiber3 D/D information: Wave length |
| 1.3.6.1.4.1.4756.20.670.20.1.91 | Columnf4G3RFx3DDWaveLen2 | read-only | current | Local FRM220-4G-3R card fiber3 D/D information: Wave length 2 |
| 1.3.6.1.4.1.4756.20.670.20.1.92 | Columnf4G3RFx3DDLinkLen | read-only | current | Local FRM220-4G-3R card fiber3 D/D information: Link length |
| 1.3.6.1.4.1.4756.20.670.20.1.93 | Columnf4G3RFx3DDLenUnit | read-only | current | Local FRM220-4G-3R card fiber3 D/D information: Length Unit |
| 1.3.6.1.4.1.4756.20.670.20.1.94 | Columnf4G3RFx3DDRxSens | read-only | current | Local FRM220-4G-3R card fiber3 D/D information: Rx Sensitivity |
| 1.3.6.1.4.1.4756.20.670.20.1.95 | Columnf4G3RFx3DDTxPWR | read-only | current | Local FRM220-4G-3R card fiber3 D/D information: Tx power |
| 1.3.6.1.4.1.4756.20.670.20.1.96 | Columnf4G3RFx3DDRxPWR | read-only | current | Local FRM220-4G-3R card fiber3 D/D information: Rx power |
| 1.3.6.1.4.1.4756.20.670.20.1.97 | Columnf4G3RFx3RxPowerStatus | read-only | current | Local FRM220-4G-3R card fiber3 Rx Power Status: 0:Normal 1:Warning 2:Alarm |
| 1.3.6.1.4.1.4756.20.670.20.1.98 | Columnf4G3RFx3DDTemp | read-only | current | Local FRM220-4G-3R card fiber3 D/D information: Temperature in degree C |
| 1.3.6.1.4.1.4756.20.670.20.1.99 | Columnf4G3RFx3DDPWRMargin | read-only | current | Local FRM220-4G-3R card fiber3 D/D information: Power margin |
| 1.3.6.1.4.1.4756.20.670.20.1.100 | Columnf4G3RFx4DDVendor | read-only | current | Local FRM220-4G-3R card fiber4 D/D information: Vendor name |
| 1.3.6.1.4.1.4756.20.670.20.1.101 | Columnf4G3RFx4DDPartNo | read-only | current | Local FRM220-4G-3R card fiber4 D/D information: Vendor part number |
| 1.3.6.1.4.1.4756.20.670.20.1.102 | Columnf4G3RFx4DDVendorSN | read-only | current | Local FRM220-4G-3R card fiber4 D/D information: Vendor Serial Number |
| 1.3.6.1.4.1.4756.20.670.20.1.103 | Columnf4G3RFx4DDFiberType | read-only | current | Local FRM220-4G-3R card fiber4 D/D information: Fiber Type |
| 1.3.6.1.4.1.4756.20.670.20.1.104 | Columnf4G3RFx4DDWaveLen | read-only | current | Local FRM220-4G-3R card fiber4 D/D information: Wave length |
| 1.3.6.1.4.1.4756.20.670.20.1.105 | Columnf4G3RFx4DDWaveLen2 | read-only | current | Local FRM220-4G-3R card fiber4 D/D information: Wave length 2 |
| 1.3.6.1.4.1.4756.20.670.20.1.106 | Columnf4G3RFx4DDLinkLen | read-only | current | Local FRM220-4G-3R card fiber4 D/D information: Link length |
| 1.3.6.1.4.1.4756.20.670.20.1.107 | Columnf4G3RFx4DDLenUnit | read-only | current | Local FRM220-4G-3R card fiber4 D/D information: Length Unit |
| 1.3.6.1.4.1.4756.20.670.20.1.108 | Columnf4G3RFx4DDRxSens | read-only | current | Local FRM220-4G-3R card fiber4 D/D information: Rx Sensitivity |
| 1.3.6.1.4.1.4756.20.670.20.1.109 | Columnf4G3RFx4DDTxPWR | read-only | current | Local FRM220-4G-3R card fiber4 D/D information: Tx power |
| 1.3.6.1.4.1.4756.20.670.20.1.110 | Columnf4G3RFx4DDRxPWR | read-only | current | Local FRM220-4G-3R card fiber4 D/D information: Rx power |
| 1.3.6.1.4.1.4756.20.670.20.1.111 | Columnf4G3RFx4RxPowerStatus | read-only | current | Local FRM220-4G-3R card fiber4 Rx Power Status: 0:Normal 1:Warning 2:Alarm |
| 1.3.6.1.4.1.4756.20.670.20.1.112 | Columnf4G3RFx4DDTemp | read-only | current | Local FRM220-4G-3R card fiber4 D/D information: Temperature in degree C |
| 1.3.6.1.4.1.4756.20.670.20.1.113 | Columnf4G3RFx4DDPWRMargin | read-only | current | Local FRM220-4G-3R card fiber4 D/D information: Power margin |
| 1.3.6.1.4.1.4756.20.670.20.1.114 | Columnf4G3RFx1RxPowerStatusAlarm | read-write | current | Local FRM220-4G-3R card Line Rx Power Status trap. 0:Disable 1:Enable |
| 1.3.6.1.4.1.4756.20.670.20.1.115 | Columnf4G3RFx1LosAssertAlarm | read-write | current | Local FRM220-4G-3R card Line LOS Assert trap. 0:Disable 1:Enable |
| 1.3.6.1.4.1.4756.20.670.20.1.116 | Columnf4G3RFx1RxPowerWarningThreshold | read-write | current | Set Line Rx Power Warning Threshold: Input range is from -60 to +10. |
| 1.3.6.1.4.1.4756.20.670.20.1.117 | Columnf4G3RFx1RxPowerAlarmThreshold | read-write | current | Set Line Rx Power Alarm Threshold: Input range is from -60 to +10. |
| 1.3.6.1.4.1.4756.20.670.20.1.118 | Columnf4G3RFx2RxPowerStatusAlarm | read-write | current | Local FRM220-4G-3R card Primary Rx Power Status trap. 0:Disable 1:Enable |
| 1.3.6.1.4.1.4756.20.670.20.1.119 | Columnf4G3RFx2LosAssertAlarm | read-write | current | Local FRM220-4G-3R card Primary LOS Assert trap. 0:Disable 1:Enable |
| 1.3.6.1.4.1.4756.20.670.20.1.120 | Columnf4G3RFx2RxPowerWarningThreshold | read-write | current | Set Primary Rx Power Warning Threshold: Input range is from -60 to +10. |
| 1.3.6.1.4.1.4756.20.670.20.1.121 | Columnf4G3RFx2RxPowerAlarmThreshold | read-write | current | Set Primary Rx Power Alarm Threshold: Input range is from -60 to +10. |
| 1.3.6.1.4.1.4756.20.670.20.1.122 | Columnf4G3RFx3RxPowerStatusAlarm | read-write | current | Local FRM220-4G-3R card Secondary Rx Power Status trap. 0:Disable 1:Enable |
| 1.3.6.1.4.1.4756.20.670.20.1.123 | Columnf4G3RFx3LosAssertAlarm | read-write | current | Local FRM220-4G-3R card Secondary LOS Assert trap. 0:Disable 1:Enable |
| 1.3.6.1.4.1.4756.20.670.20.1.124 | Columnf4G3RFx3RxPowerWarningThreshold | read-write | current | Set Secondary Rx Power Warning Threshold: Input range is from -60 to +10. |
| 1.3.6.1.4.1.4756.20.670.20.1.125 | Columnf4G3RFx3RxPowerAlarmThreshold | read-write | current | Set Secondary Rx Power Alarm Threshold: Input range is from -60 to +10. |
| 1.3.6.1.4.1.4756.20.670.20.1.126 | Columnf4G3RFx4RxPowerStatusAlarm | read-write | current | Local FRM220-4G-3R card Fx4 Rx Power Status trap. 0:Disable 1:Enable |
| 1.3.6.1.4.1.4756.20.670.20.1.127 | Columnf4G3RFx4LosAssertAlarm | read-write | current | Local FRM220-4G-3R card Fx4 LOS Assert trap. 0:Disable 1:Enable |
| 1.3.6.1.4.1.4756.20.670.20.1.128 | Columnf4G3RFx4RxPowerWarningThreshold | read-write | current | Set Secondary Rx Power Warning Threshold: Input range is from -60 to +10. |
| 1.3.6.1.4.1.4756.20.670.20.1.129 | Columnf4G3RFx4RxPowerAlarmThreshold | read-write | current | Set Secondary Rx Power Alarm Threshold: Input range is from -60 to +10. |
| 1.3.6.1.4.1.4756.20.670.20.1.130 | Columnf4G3RTemperature | read-only | current | Local FRM220-4G-3R card temperature information: Temperature in degree C |
| 1.3.6.1.4.1.4756.20.670.20.1.131 | Columnf4G3RPowerLed | read-only | current | Local FRM220-4G-3R card Powe Led. 0:ON (Power ON) 1:Flash (Standby; 1s ON/1s OFF) |
| 1.3.6.1.4.1.4756.20.670.20.1.132 | Columnf4G3RSystemLed | read-only | current | Local FRM220-4G-3R card Syetem Led. 0:OFF(Fail) 1:ON (Normal) |
| 1.3.6.1.4.1.4756.20.670.20.1.133 | Columnf4G3RModeLed | read-only | current | Local FRM220-4G-3R card Mode Led. 0:OFF(Dual Channel) 1:ON (Protection) |
| 1.3.6.1.4.1.4756.20.670.20.1.134 | Columnf4G3RTestLed | read-only | current | Local FRM220-4G-3R card Test Led. 0:OFF(Normal) 1:ON (Test; Loopback Test) |
| 1.3.6.1.4.1.4756.20.670.20.1.135 | Columnf4G3RFx1Led | read-only | current | Local FRM220-4G-3R card Fx1 Led. 0:OFF(Link Down) 1:ON (SYNC) 2:LB (0.1s ON/0.1s OFF) 3:Link Up (0.5s ON/0.5s OFF) |
| 1.3.6.1.4.1.4756.20.670.20.1.136 | Columnf4G3RFx2Led | read-only | current | Local FRM220-4G-3R card Fx2 Led. 0:OFF(Link Down) 1:ON (SYNC) 2:LB (0.1s ON/0.1s OFF) 3:Link Up (0.5s ON/0.5s OFF) 4:Working Path (3s ON/0.2s OFF) |
| 1.3.6.1.4.1.4756.20.670.20.1.137 | Columnf4G3RFx3Led | read-only | current | Local FRM220-4G-3R card Fx3 Led. 0:OFF(Link Down) 1:ON (SYNC) 2:LB (0.1s ON/0.1s OFF) 3:Link Up (0.5s ON/0.5s OFF) 4:Working Path (3s ON/0.2s OFF) |
| 1.3.6.1.4.1.4756.20.670.20.1.138 | Columnf4G3RFx4Led | read-only | current | Local FRM220-4G-3R card Fx4 Led. 0:OFF(Link Down) 1:ON (SYNC) 2:LB (0.1s ON/0.1s OFF) 3:Link Up (0.5s ON/0.5s OFF) |
| 1.3.6.1.4.1.4756.20.680 | Nodef10G3RCards | |||
| 1.3.6.1.4.1.4756.20.680.20 | Tablef10G3RTable | not-accessible | current | A list of local FRM220-10G-3R card entries. The number of entries is f10G3R-No-L. |
| 1.3.6.1.4.1.4756.20.680.20.1 | Rowf10G3REntry | not-accessible | current | An entry containing management information applicable to a particular local FRM220-10G-3R card. |
| 1.3.6.1.4.1.4756.20.680.20.1.1 | Columnf10G3RChassisIndex | read-only | current | A unique value for each local card. It is the chassis location number. |
| 1.3.6.1.4.1.4756.20.680.20.1.2 | Columnf10G3RSlotIndex | read-only | current | A unique value for each local card. It is the slot location number. |
| 1.3.6.1.4.1.4756.20.680.20.1.3 | Columnf10G3RCardHWVer | read-only | current | Local FRM220-10G-3R card hardware version x.xxx |
| 1.3.6.1.4.1.4756.20.680.20.1.4 | Columnf10G3RCardFWVer | read-only | current | Local FRM220-10G-3R card firmware version x.xxx |
| 1.3.6.1.4.1.4756.20.680.20.1.5 | Columnf10G3RCardCPLDVer | read-only | current | Local FRM220-10G-3R card CPLD version x.xxx |
| 1.3.6.1.4.1.4756.20.680.20.1.6 | Columnf10G3RCardFPGAVer | read-only | current | Local FRM220-10G-3R card FPGA version x.xxx |
| 1.3.6.1.4.1.4756.20.680.20.1.7 | Columnf10G3RFx1Link | read-only | current | Local FRM220-10G-3R card Fiber1 link status: 0:Down 1:Up |
| 1.3.6.1.4.1.4756.20.680.20.1.8 | Columnf10G3RFx2Link | read-only | current | Local FRM220-10G-3R card Fiber2 link status: 0:Down 1:Up |
| 1.3.6.1.4.1.4756.20.680.20.1.9 | Columnf10G3RFx3Link | read-only | current | Local FRM220-10G-3R card Fiber3 link status: 0:Down 1:Up |
| 1.3.6.1.4.1.4756.20.680.20.1.10 | Columnf10G3RFx4Link | read-only | current | Local FRM220-10G-3R card Fiber4 link status: 0:Down 1:Up |
| 1.3.6.1.4.1.4756.20.680.20.1.11 | Columnf10G3RFx1CDRLocked | read-only | current | Local FRM220-10G-3R card Fiber1 CRD Locked: 0:Not Locked 1:Locked |
| 1.3.6.1.4.1.4756.20.680.20.1.12 | Columnf10G3RFx2CDRLocked | read-only | current | Local FRM220-10G-3R card Fiber2 CRD Locked: 0:Not Locked 1:Locked |
| 1.3.6.1.4.1.4756.20.680.20.1.13 | Columnf10G3RFx3CDRLocked | read-only | current | Local FRM220-10G-3R card Fiber3 CRD Locked: 0:Not Locked 1:Locked |
| 1.3.6.1.4.1.4756.20.680.20.1.14 | Columnf10G3RFx4CDRLocked | read-only | current | Local FRM220-10G-3R card Fiber4 CRD Locked: 0:Not Locked 1:Locked |
| 1.3.6.1.4.1.4756.20.680.20.1.15 | Columnf10G3RFx1TxFault | read-only | current | Local FRM220-10G-3R card Fiber1 Tx Fault: 0:Normal 1:Failure |
| 1.3.6.1.4.1.4756.20.680.20.1.16 | Columnf10G3RFx2TxFault | read-only | current | Local FRM220-10G-3R card Fiber2 Tx Fault: 0:Normal 1:Failure |
| 1.3.6.1.4.1.4756.20.680.20.1.17 | Columnf10G3RFx3TxFault | read-only | current | Local FRM220-10G-3R card Fiber3 Tx Fault: 0:Normal 1:Failure |
| 1.3.6.1.4.1.4756.20.680.20.1.18 | Columnf10G3RFx4TxFault | read-only | current | Local FRM220-10G-3R card Fiber4 Tx Fault: 0:Normal 1:Failure |
| 1.3.6.1.4.1.4756.20.680.20.1.19 | Columnf10G3RFx1DD | read-only | current | Local FRM220-10G-3R card fiber1 Digital Diagnostic function: 0:No 1:Yes |
| 1.3.6.1.4.1.4756.20.680.20.1.20 | Columnf10G3RFx2DD | read-only | current | Local FRM220-10G-3R card fiber2 Digital Diagnostic function: 0:No 1:Yes |
| 1.3.6.1.4.1.4756.20.680.20.1.21 | Columnf10G3RFx3DD | read-only | current | Local FRM220-10G-3R card fiber3 Digital Diagnostic function: 0:No 1:Yes |
| 1.3.6.1.4.1.4756.20.680.20.1.22 | Columnf10G3RFx4DD | read-only | current | Local FRM220-10G-3R card fiber4 Digital Diagnostic function: 0:No 1:Yes |
| 1.3.6.1.4.1.4756.20.680.20.1.23 | Columnf10G3RFx1DDStatus | read-only | current | Local FRM220-10G-3R card fiber1 D/D information: Status Support |
| 1.3.6.1.4.1.4756.20.680.20.1.24 | Columnf10G3RFx2DDStatus | read-only | current | Local FRM220-10G-3R card fiber2 D/D information: Status Support |
| 1.3.6.1.4.1.4756.20.680.20.1.25 | Columnf10G3RFx3DDStatus | read-only | current | Local FRM220-10G-3R card fiber3 D/D information: Status Support |
| 1.3.6.1.4.1.4756.20.680.20.1.26 | Columnf10G3RFx4DDStatus | read-only | current | Local FRM220-10G-3R card fiber4 D/D information: Status Support |
| 1.3.6.1.4.1.4756.20.680.20.1.27 | Columnf10G3RDeviceActive | read-write | current | Local FRM220-10G-3R card active: 0:Inactive 1:Active |
| 1.3.6.1.4.1.4756.20.680.20.1.28 | Columnf10G3RPortReset | read-write | current | Force local FRM220-10G-3R card to reset mode: 0:Off 1:Action |
| 1.3.6.1.4.1.4756.20.680.20.1.29 | Columnf10G3RSetDefault | read-write | current | Local FRM220-10G-3R card set to default : 0:Off 1:Action |
| 1.3.6.1.4.1.4756.20.680.20.1.30 | Columnf10G3RWorkMode | read-write | current | Local FRM220-10G-3R card Work Mode : 0:Protection 1:Dual Channel |
| 1.3.6.1.4.1.4756.20.680.20.1.31 | Columnf10G3RFx1Lbsetting | read-write | current | Local FRM220-10G-3R card Fiber1 Loopback: 0:Disable 1:Enable |
| 1.3.6.1.4.1.4756.20.680.20.1.32 | Columnf10G3RFx2Lbsetting | read-write | current | Local FRM220-10G-3R card Fiber2 Loopback: 0:Disable 1:Enable |
| 1.3.6.1.4.1.4756.20.680.20.1.33 | Columnf10G3RFx3Lbsetting | read-write | current | Local FRM220-10G-3R card Fiber3 Loopback: 0:Disable 1:Enable |
| 1.3.6.1.4.1.4756.20.680.20.1.34 | Columnf10G3RFx4Lbsetting | read-write | current | Local FRM220-10G-3R card Fiber4 Loopback: 0:Disable 1:Enable |
| 1.3.6.1.4.1.4756.20.680.20.1.35 | Columnf10G3RFx1LFPT | read-write | current | Local FRM220-10G-3R card Fiber1 Link Fault Pass Through: 0:Disable 1:Enable |
| 1.3.6.1.4.1.4756.20.680.20.1.36 | Columnf10G3RFx2LFPT | read-write | current | Local FRM220-10G-3R card Fiber2 Link Fault Pass Through: 0:Disable 1:Enable |
| 1.3.6.1.4.1.4756.20.680.20.1.37 | Columnf10G3RFx3LFPT | read-write | current | Local FRM220-10G-3R card Fiber3 Link Fault Pass Through: 0:Disable 1:Enable |
| 1.3.6.1.4.1.4756.20.680.20.1.38 | Columnf10G3RFx4LFPT | read-write | current | Local FRM220-10G-3R card Fiber4 Link Fault Pass Through: 0:Disable 1:Enable |
| 1.3.6.1.4.1.4756.20.680.20.1.39 | Columnf10G3RFx1ALSMode | read-write | current | Local FRM220-10G-3R card Fiber1 Auto Laser Showdown: 0:Disable 1:Enable |
| 1.3.6.1.4.1.4756.20.680.20.1.40 | Columnf10G3RFx2ALSMode | read-write | current | Local FRM220-10G-3R card Fiber2 Auto Laser Showdown: 0:Disable 1:Enable |
| 1.3.6.1.4.1.4756.20.680.20.1.41 | Columnf10G3RFx3ALSMode | read-write | current | Local FRM220-10G-3R card Fiber3 Auto Laser Showdown: 0:Disable 1:Enable |
| 1.3.6.1.4.1.4756.20.680.20.1.42 | Columnf10G3RFx4ALSMode | read-write | current | Local FRM220-10G-3R card Fiber4 Auto Laser Showdown: 0:Disable 1:Enable |
| 1.3.6.1.4.1.4756.20.680.20.1.43 | Columnf10G3RFx1LinkAlarm | read-write | current | Local FRM220-10G-3R card Fx1 Link Alarm: 0:Disalbe 1:Enable |
| 1.3.6.1.4.1.4756.20.680.20.1.44 | Columnf10G3RFx2LinkAlarm | read-write | current | Local FRM220-10G-3R card Fx2 Link Alarm: 0:Disalbe 1:Enable |
| 1.3.6.1.4.1.4756.20.680.20.1.45 | Columnf10G3RFx3LinkAlarm | read-write | current | Local FRM220-10G-3R card Fx3 Link Alarm: 0:Disalbe 1:Enable |
| 1.3.6.1.4.1.4756.20.680.20.1.46 | Columnf10G3RFx4LinkAlarm | read-write | current | Local FRM220-10G-3R card Fx4 Link Alarm: 0:Disalbe 1:Enable |
| 1.3.6.1.4.1.4756.20.680.20.1.47 | Columnf10G3RSemiActive | read-write | current | Local FRM220-10G-3R card Semi-Active (Protection mode only): 0:Disalbe 1:Enable |
| 1.3.6.1.4.1.4756.20.680.20.1.48 | Columnf10G3RWorkingPathStatus | read-only | current | Local FRM220-10G-3R card Workinng Path Status (Protection mode only): 0:Primary 1:Secondary |
| 1.3.6.1.4.1.4756.20.680.20.1.49 | Columnf10G3RWorkingPath | read-write | current | Local FRM220-10G-3R card Workinng Path(Protection mode only): 0:Auto-Revert 1:Non Revert 2:Primary 3:Secondary |
| 1.3.6.1.4.1.4756.20.680.20.1.50 | Columnf10G3RDataRatelStatus | read-only | current | Local FRM220-10G-3R card Data Rate 1 Status: |
| 1.3.6.1.4.1.4756.20.680.20.1.51 | Columnf10G3RDataRate2Status | read-only | current | Local FRM220-10G-3R card Data Rate 2 Status(Dual Channel mode only): |
| 1.3.6.1.4.1.4756.20.680.20.1.52 | Columnf10G3RProtocol1 | read-only | current | Local FRM220-10G-3R card Protocol 1: 0:Ethernet 1:SONET/SDH 2:Fiber Channel 3:CPRI 4:OBSAI 5:OTU 6:ODU |
| 1.3.6.1.4.1.4756.20.680.20.1.53 | Columnf10G3RRate1 | read-write | current | Local FRM220-10G-3R card Rate 1: Ethernet 0: 10GE 1: 1GE 2: 2500Base-X SONET/SDH 8: OC-192/STM-64 9: OC-48/STM-16 10:OC-24 11:OC-12/STM-4 Fiber Channel 16: 10G… |
| 1.3.6.1.4.1.4756.20.680.20.1.54 | Columnf10G3RProtocol2 | read-only | current | Local FRM220-10G-3R Protocol 2 (Dual Channel only): 0:Ethernet 1:SONET/SDH 2:Fiber Channel 3:CPRI 4:OBSAI 5:OTU 6:ODU |
| 1.3.6.1.4.1.4756.20.680.20.1.55 | Columnf10G3RRate2 | read-write | current | Local FRM220-10G-3R card Rate2(Dual Channel only): Ethernet 0: 10GE 1: 1GE 2: 2500Base-X SONET/SDH 8: OC-192/STM-64 9: OC-48/STM-16 10:OC-24 11:OC-12/STM-4 Fib… |
| 1.3.6.1.4.1.4756.20.680.20.1.56 | Columnf10G3RChannel1Active | read-write | current | Local FRM220-10G-3R card Channel 1 Active(Dual Channel only): 0:Disable 1:Enable |
| 1.3.6.1.4.1.4756.20.680.20.1.57 | Columnf10G3RChannel2Active | read-write | current | Local FRM220-10G-3R card Channel 2 Active(Dual Channel only): 0:Disable 1:Enable |
| 1.3.6.1.4.1.4756.20.680.20.1.58 | Columnf10G3RFx1DDVendor | read-only | current | Local FRM220-10G-3R card fiber1 D/D information: Vendor name |
| 1.3.6.1.4.1.4756.20.680.20.1.59 | Columnf10G3RFx1DDPartNo | read-only | current | Local FRM220-10G-3R card fiber1 D/D information: Vendor part number |
| 1.3.6.1.4.1.4756.20.680.20.1.60 | Columnf10G3RFx1DDVendorSN | read-only | current | Local FRM220-10G-3R card fiber1 D/D information: Vendor Serial number |
| 1.3.6.1.4.1.4756.20.680.20.1.61 | Columnf10G3RFx1DDFiberType | read-only | current | Local FRM220-10G-3R card fiber1 D/D information: Fiber Type |
| 1.3.6.1.4.1.4756.20.680.20.1.62 | Columnf10G3RFx1DDWaveLen | read-only | current | Local FRM220-10G-3R card fiber1 D/D information: Wave length |
| 1.3.6.1.4.1.4756.20.680.20.1.63 | Columnf10G3RFx1DDWaveLen2 | read-only | current | Local FRM220-10G-3R card fiber1 D/D information: Wave length 2 |
| 1.3.6.1.4.1.4756.20.680.20.1.64 | Columnf10G3RFx1DDLinkLen | read-only | current | Local FRM220-10G-3R card fiber1 D/D information: Link length |
| 1.3.6.1.4.1.4756.20.680.20.1.65 | Columnf10G3RFx1DDLenUnit | read-only | current | Local FRM220-10G-3R card fiber1 D/D information: Length Unit |
| 1.3.6.1.4.1.4756.20.680.20.1.66 | Columnf10G3RFx1DDRxSens | read-only | current | Local FRM220-10G-3R card fiber1 D/D information: Rx Sensitivity |
| 1.3.6.1.4.1.4756.20.680.20.1.67 | Columnf10G3RFx1DDTxPWR | read-only | current | Local FRM220-10G-3R card fiber1 D/D information: Tx power |
| 1.3.6.1.4.1.4756.20.680.20.1.68 | Columnf10G3RFx1DDRxPWR | read-only | current | Local FRM220-10G-3R card fiber1 D/D information: Rx power |
| 1.3.6.1.4.1.4756.20.680.20.1.69 | Columnf10G3RFx1RxPowerStatus | read-only | current | Local FRM220-10G-3R card fiber1 Rx Power Status: 0:Normal 1:Warning 2:Alarm |
| 1.3.6.1.4.1.4756.20.680.20.1.70 | Columnf10G3RFx1DDTemp | read-only | current | Local FRM220-10G-3R card fiber1 D/D information: Temperature in degree C |
| 1.3.6.1.4.1.4756.20.680.20.1.71 | Columnf10G3RFx1DDPWRMargin | read-only | current | Local FRM220-10G-3R card fiber1 D/D information: Power margin |
| 1.3.6.1.4.1.4756.20.680.20.1.72 | Columnf10G3RFx2DDVendor | read-only | current | Local FRM220-10G-3R card fiber2 D/D information: Vendor name |
| 1.3.6.1.4.1.4756.20.680.20.1.73 | Columnf10G3RFx2DDPartNo | read-only | current | Local FRM220-10G-3R card fiber2 D/D information: Vendor part number |
| 1.3.6.1.4.1.4756.20.680.20.1.74 | Columnf10G3RFx2DDVendorSN | read-only | current | Local FRM220-10G-3R card fiber2 D/D information: Vendor Serial number |
| 1.3.6.1.4.1.4756.20.680.20.1.75 | Columnf10G3RFx2DDFiberType | read-only | current | Local FRM220-10G-3R card fiber2 D/D information: Fiber Type |
| 1.3.6.1.4.1.4756.20.680.20.1.76 | Columnf10G3RFx2DDWaveLen | read-only | current | Local FRM220-10G-3R card fiber2 D/D information: Wave length |
| 1.3.6.1.4.1.4756.20.680.20.1.77 | Columnf10G3RFx2DDWaveLen2 | read-only | current | Local FRM220-10G-3R card fiber2 D/D information: Wave length 2 |
| 1.3.6.1.4.1.4756.20.680.20.1.78 | Columnf10G3RFx2DDLinkLen | read-only | current | Local FRM220-10G-3R card fiber2 D/D information: Link length |
| 1.3.6.1.4.1.4756.20.680.20.1.79 | Columnf10G3RFx2DDLenUnit | read-only | current | Local FRM220-10G-3R card fiber2 D/D information: Length Unit |
| 1.3.6.1.4.1.4756.20.680.20.1.80 | Columnf10G3RFx2DDRxSens | read-only | current | Local FRM220-10G-3R card fiber2 D/D information: Rx Sensitivity |
| 1.3.6.1.4.1.4756.20.680.20.1.81 | Columnf10G3RFx2DDTxPWR | read-only | current | Local FRM220-10G-3R card fiber2 D/D information: Tx power |
| 1.3.6.1.4.1.4756.20.680.20.1.82 | Columnf10G3RFx2DDRxPWR | read-only | current | Local FRM220-10G-3R card fiber2 D/D information: Rx power |
| 1.3.6.1.4.1.4756.20.680.20.1.83 | Columnf10G3RFx2RxPowerStatus | read-only | current | Local FRM220-10G-3R card fiber2 Rx Power Status: 0:Normal 1:Warning 2:Alarm |
| 1.3.6.1.4.1.4756.20.680.20.1.84 | Columnf10G3RFx2DDTemp | read-only | current | Local FRM220-10G-3R card fiber2 D/D information: Temperature in degree C |
| 1.3.6.1.4.1.4756.20.680.20.1.85 | Columnf10G3RFx2DDPWRMargin | read-only | current | Local FRM220-10G-3R card fiber2 D/D information: Power margin |
| 1.3.6.1.4.1.4756.20.680.20.1.86 | Columnf10G3RFx3DDVendor | read-only | current | Local FRM220-10G-3R card fiber3 D/D information: Vendor name |
| 1.3.6.1.4.1.4756.20.680.20.1.87 | Columnf10G3RFx3DDPartNo | read-only | current | Local FRM220-10G-3R card fiber3 D/D information: Vendor part number |
| 1.3.6.1.4.1.4756.20.680.20.1.88 | Columnf10G3RFx3DDVendorSN | read-only | current | Local FRM220-10G-3R card fiber3 D/D information: Vendor Serial number |
| 1.3.6.1.4.1.4756.20.680.20.1.89 | Columnf10G3RFx3DDFiberType | read-only | current | Local FRM220-10G-3R card fiber3 D/D information: Fiber Type |
| 1.3.6.1.4.1.4756.20.680.20.1.90 | Columnf10G3RFx3DDWaveLen | read-only | current | Local FRM220-10G-3R card fiber3 D/D information: Wave length |
| 1.3.6.1.4.1.4756.20.680.20.1.91 | Columnf10G3RFx3DDWaveLen2 | read-only | current | Local FRM220-10G-3R card fiber3 D/D information: Wave length 2 |
| 1.3.6.1.4.1.4756.20.680.20.1.92 | Columnf10G3RFx3DDLinkLen | read-only | current | Local FRM220-10G-3R card fiber3 D/D information: Link length |
| 1.3.6.1.4.1.4756.20.680.20.1.93 | Columnf10G3RFx3DDLenUnit | read-only | current | Local FRM220-10G-3R card fiber3 D/D information: Length Unit |
| 1.3.6.1.4.1.4756.20.680.20.1.94 | Columnf10G3RFx3DDRxSens | read-only | current | Local FRM220-10G-3R card fiber3 D/D information: Rx Sensitivity |
| 1.3.6.1.4.1.4756.20.680.20.1.95 | Columnf10G3RFx3DDTxPWR | read-only | current | Local FRM220-10G-3R card fiber3 D/D information: Tx power |
| 1.3.6.1.4.1.4756.20.680.20.1.96 | Columnf10G3RFx3DDRxPWR | read-only | current | Local FRM220-10G-3R card fiber3 D/D information: Rx power |
| 1.3.6.1.4.1.4756.20.680.20.1.97 | Columnf10G3RFx3RxPowerStatus | read-only | current | Local FRM220-10G-3R card fiber3 Rx Power Status: 0:Normal 1:Warning 2:Alarm |
| 1.3.6.1.4.1.4756.20.680.20.1.98 | Columnf10G3RFx3DDTemp | read-only | current | Local FRM220-10G-3R card fiber3 D/D information: Temperature in degree C |
| 1.3.6.1.4.1.4756.20.680.20.1.99 | Columnf10G3RFx3DDPWRMargin | read-only | current | Local FRM220-10G-3R card fiber3 D/D information: Power margin |
| 1.3.6.1.4.1.4756.20.680.20.1.100 | Columnf10G3RFx4DDVendor | read-only | current | Local FRM220-10G-3R card fiber4 D/D information: Vendor name |
| 1.3.6.1.4.1.4756.20.680.20.1.101 | Columnf10G3RFx4DDPartNo | read-only | current | Local FRM220-10G-3R card fiber4 D/D information: Vendor part number |
| 1.3.6.1.4.1.4756.20.680.20.1.102 | Columnf10G3RFx4DDVendorSN | read-only | current | Local FRM220-10G-3R card fiber4 D/D information: Vendor Serial number |
| 1.3.6.1.4.1.4756.20.680.20.1.103 | Columnf10G3RFx4DDFiberType | read-only | current | Local FRM220-10G-3R card fiber4 D/D information: Fiber Type |
| 1.3.6.1.4.1.4756.20.680.20.1.104 | Columnf10G3RFx4DDWaveLen | read-only | current | Local FRM220-10G-3R card fiber4 D/D information: Wave length |
| 1.3.6.1.4.1.4756.20.680.20.1.105 | Columnf10G3RFx4DDWaveLen2 | read-only | current | Local FRM220-10G-3R card fiber4 D/D information: Wave length 2 |
| 1.3.6.1.4.1.4756.20.680.20.1.106 | Columnf10G3RFx4DDLinkLen | read-only | current | Local FRM220-10G-3R card fiber4 D/D information: Link length |
| 1.3.6.1.4.1.4756.20.680.20.1.107 | Columnf10G3RFx4DDLenUnit | read-only | current | Local FRM220-10G-3R card fiber4 D/D information: Length Unit |
| 1.3.6.1.4.1.4756.20.680.20.1.108 | Columnf10G3RFx4DDRxSens | read-only | current | Local FRM220-10G-3R card fiber4 D/D information: Rx Sensitivity |
| 1.3.6.1.4.1.4756.20.680.20.1.109 | Columnf10G3RFx4DDTxPWR | read-only | current | Local FRM220-10G-3R card fiber4 D/D information: Tx power |
| 1.3.6.1.4.1.4756.20.680.20.1.110 | Columnf10G3RFx4DDRxPWR | read-only | current | Local FRM220-10G-3R card fiber4 D/D information: Rx power |
| 1.3.6.1.4.1.4756.20.680.20.1.111 | Columnf10G3RFx4RxPowerStatus | read-only | current | Local FRM220-10G-3R card fiber4 Rx Power Status: 0:Normal 1:Warning 2:Alarm |
| 1.3.6.1.4.1.4756.20.680.20.1.112 | Columnf10G3RFx4DDTemp | read-only | current | Local FRM220-10G-3R card fiber4 D/D information: Temperature in degree C |
| 1.3.6.1.4.1.4756.20.680.20.1.113 | Columnf10G3RFx4DDPWRMargin | read-only | current | Local FRM220-10G-3R card fiber4 D/D information: Power margin |
| 1.3.6.1.4.1.4756.20.680.20.1.114 | Columnf10G3RFx1RxPowerStatusAlarm | read-write | current | Local FRM220-10G-3R card Line Rx Power Status trap. 0:Disable 1:Enable |
| 1.3.6.1.4.1.4756.20.680.20.1.115 | Columnf10G3RFx1LosAssertAlarm | read-write | current | Local FRM220-10G-3R card Line LOS Assert trap. 0:Disable 1:Enable |
| 1.3.6.1.4.1.4756.20.680.20.1.116 | Columnf10G3RFx1RxPowerWarningThreshold | read-write | current | Set Line Rx Power Warning Threshold: Input range is from -60 to +10. |
| 1.3.6.1.4.1.4756.20.680.20.1.117 | Columnf10G3RFx1RxPowerAlarmThreshold | read-write | current | Set Line Rx Power Alarm Threshold: Input range is from -60 to +10. |
| 1.3.6.1.4.1.4756.20.680.20.1.118 | Columnf10G3RFx2RxPowerStatusAlarm | read-write | current | Local FRM220-10G-3R card Primary Rx Power Status trap. 0:Disable 1:Enable |
| 1.3.6.1.4.1.4756.20.680.20.1.119 | Columnf10G3RFx2LosAssertAlarm | read-write | current | Local FRM220-10G-3R card Primary LOS Assert trap. 0:Disable 1:Enable |
| 1.3.6.1.4.1.4756.20.680.20.1.120 | Columnf10G3RFx2RxPowerWarningThreshold | read-write | current | Set Primary Rx Power Warning Threshold: Input range is from -60 to +10. |
| 1.3.6.1.4.1.4756.20.680.20.1.121 | Columnf10G3RFx2RxPowerAlarmThreshold | read-write | current | Set Primary Rx Power Alarm Threshold: Input range is from -60 to +10. |
| 1.3.6.1.4.1.4756.20.680.20.1.122 | Columnf10G3RFx3RxPowerStatusAlarm | read-write | current | Local FRM220-10G-3R card Secondary Rx Power Status trap. 0:Disable 1:Enable |
| 1.3.6.1.4.1.4756.20.680.20.1.123 | Columnf10G3RFx3LosAssertAlarm | read-write | current | Local FRM220-10G-3R card Secondary LOS Assert trap. 0:Disable 1:Enable |
| 1.3.6.1.4.1.4756.20.680.20.1.124 | Columnf10G3RFx3RxPowerWarningThreshold | read-write | current | Set Secondary Rx Power Warning Threshold: Input range is from -60 to +10. |
| 1.3.6.1.4.1.4756.20.680.20.1.125 | Columnf10G3RFx3RxPowerAlarmThreshold | read-write | current | Set Secondary Rx Power Alarm Threshold: Input range is from -60 to +10. |
| 1.3.6.1.4.1.4756.20.680.20.1.126 | Columnf10G3RFx4RxPowerStatusAlarm | read-write | current | Local FRM220-10G-3R card Fx4 Rx Power Status trap. 0:Disable 1:Enable |
| 1.3.6.1.4.1.4756.20.680.20.1.127 | Columnf10G3RFx4LosAssertAlarm | read-write | current | Local FRM220-10G-3R card Fx4 LOS Assert trap. 0:Disable 1:Enable |
| 1.3.6.1.4.1.4756.20.680.20.1.128 | Columnf10G3RFx4RxPowerWarningThreshold | read-write | current | Set Secondary Rx Power Warning Threshold: Input range is from -60 to +10. |
| 1.3.6.1.4.1.4756.20.680.20.1.129 | Columnf10G3RFx4RxPowerAlarmThreshold | read-write | current | Set Secondary Rx Power Alarm Threshold: Input range is from -60 to +10. |
| 1.3.6.1.4.1.4756.20.680.20.1.130 | Columnf10G3RTemperature | read-only | current | Local FRM220-10G-3R card temperature information: Temperature in degree C |
| 1.3.6.1.4.1.4756.20.680.20.1.131 | Columnf10G3RPowerLed | read-only | current | Local FRM220-10G-3R card Powe Led. 0:ON (Power ON) 1:Flash (Standby; 1s ON/1s OFF) |
| 1.3.6.1.4.1.4756.20.680.20.1.132 | Columnf10G3RSystemLed | read-only | current | Local FRM220-10G-3R card Syetem Led. 0:OFF(Fail) 1:ON (Normal) |
| 1.3.6.1.4.1.4756.20.680.20.1.133 | Columnf10G3RModeLed | read-only | current | Local FRM220-10G-3R card Mode Led. 0:OFF(Dual Channel) 1:ON (Protection) |
| 1.3.6.1.4.1.4756.20.680.20.1.134 | Columnf10G3RTestLed | read-only | current | Local FRM220-10G-3R card Test Led. 0:OFF(Normal) 1:ON (Test; Loopback Test) |
| 1.3.6.1.4.1.4756.20.680.20.1.135 | Columnf10G3RFx1Led | read-only | current | Local FRM220-10G-3R card Fx1 Led. 0:OFF(Link Down) 1:ON (SYNC) 2:LB (0.1s ON/0.1s OFF) 3:Link Up (0.5s ON/0.5s OFF) |
| 1.3.6.1.4.1.4756.20.680.20.1.136 | Columnf10G3RFx2Led | read-only | current | Local FRM220-10G-3R card Fx2 Led. 0:OFF(Link Down) 1:ON (SYNC) 2:LB (0.1s ON/0.1s OFF) 3:Link Up (0.5s ON/0.5s OFF) 4:Working Path (3s ON/0.2s OFF) |
| 1.3.6.1.4.1.4756.20.680.20.1.137 | Columnf10G3RFx3Led | read-only | current | Local FRM220-10G-3R card Fx3 Led. 0:OFF(Link Down) 1:ON (SYNC) 2:LB (0.1s ON/0.1s OFF) 3:Link Up (0.5s ON/0.5s OFF) 4:Working Path (3s ON/0.2s OFF) |
| 1.3.6.1.4.1.4756.20.680.20.1.138 | Columnf10G3RFx4Led | read-only | current | Local FRM220-10G-3R card Fx4 Led. 0:OFF(Link Down) 1:ON (SYNC) 2:LB (0.1s ON/0.1s OFF) 3:Link Up (0.5s ON/0.5s OFF) |
| 1.3.6.1.4.1.4756.20.680.20.1.139 | Columnf10G3RTunableFx1chORfreq | read-write | current | Local FRM220-10G-3R card Tunable Fiber 1 (CH1-1) chORfreq Mode. 0: Channel 1: Frequency |
| 1.3.6.1.4.1.4756.20.680.20.1.140 | Columnf10G3RTunableFx2chORfreq | read-write | current | Local FRM220-10G-3R card Tunable Fiber 2 (CH1-2) chORfreq Mode. 0: Channel 1: Frequency |
| 1.3.6.1.4.1.4756.20.680.20.1.141 | Columnf10G3RTunableFx3chORfreq | read-write | current | Local FRM220-10G-3R card Tunable Fiber 3 (CH2-3) chORfreq Mode. 0: Channel 1: Frequency |
| 1.3.6.1.4.1.4756.20.680.20.1.142 | Columnf10G3RTunableFx4chORfreq | read-write | current | Local FRM220-10G-3R card Tunable Fiber 4 (CH2-4) chORfreq Mode. 0: Channel 1: Frequency |
| 1.3.6.1.4.1.4756.20.680.20.1.143 | Columnf10G3RTunableFx1Channel | read-write | current | Local FRM220-10G-3R card Tunable Fiber 1 (CH1-1) Channel setting. |
| 1.3.6.1.4.1.4756.20.680.20.1.144 | Columnf10G3RTunableFx2Channel | read-write | current | Local FRM220-10G-3R card Tunable Fiber 2 (CH1-2) Channel setting. |
| 1.3.6.1.4.1.4756.20.680.20.1.145 | Columnf10G3RTunableFx3Channel | read-write | current | Local FRM220-10G-3R card Tunable Fiber 3 (CH2-3) Channel setting. |
| 1.3.6.1.4.1.4756.20.680.20.1.146 | Columnf10G3RTunableFx4Channel | read-write | current | Local FRM220-10G-3R card Tunable Fiber 4 (CH2-4) Channel setting. |
| 1.3.6.1.4.1.4756.20.680.20.1.147 | Columnf10G3RFx1TempAlarm | read-write | current | Local FRM220-10G-3R card Fiber 1 (CH1-1) over temperature alarm. 0: Disable 1: Enable 2: Not Support Tunable SFP |
| 1.3.6.1.4.1.4756.20.680.20.1.148 | Columnf10G3RFx2TempAlarm | read-write | current | Local FRM220-10G-3R card Fiber 2 (CH1-2) over temperature alarm. 0: Disable 1: Enable 2: Not Support Tunable SFP |
| 1.3.6.1.4.1.4756.20.680.20.1.149 | Columnf10G3RFx3TempAlarm | read-write | current | Local FRM220-10G-3R card Fiber 3 (CH2-3) over temperature alarm. 0: Disable 1: Enable 2: Not Support Tunable SFP |
| 1.3.6.1.4.1.4756.20.680.20.1.150 | Columnf10G3RFx4TempAlarm | read-write | current | Local FRM220-10G-3R card Fiber 4 (CH2-4) over temperature alarm. 0: Disable 1: Enable 2: Not Support Tunable SFP |
| 1.3.6.1.4.1.4756.20.680.20.1.151 | Columnf10G3RTunableFx1Frequency | read-write | current | Local FRM220-10G-3R card Tunable Fiber 1 (CH1-1) Frequency setting. |
| 1.3.6.1.4.1.4756.20.680.20.1.152 | Columnf10G3RTunableFx2Frequency | read-write | current | Local FRM220-10G-3R card Tunable Fiber 2 (CH1-2) Frequency setting. |
| 1.3.6.1.4.1.4756.20.680.20.1.153 | Columnf10G3RTunableFx3Frequency | read-write | current | Local FRM220-10G-3R card Tunable Fiber 3 (CH2-3) Frequency setting. |
| 1.3.6.1.4.1.4756.20.680.20.1.154 | Columnf10G3RTunableFx4Frequency | read-write | current | Local FRM220-10G-3R card Tunable Fiber 4 (CH2-4) Frequency setting. |
| 1.3.6.1.4.1.4756.20.690 | Nodef40G2QCards | |||
| 1.3.6.1.4.1.4756.20.690.20 | Tablef40G2QTable | not-accessible | current | A list of local FRM220-40G-2Q Line Card entries. The number of entries is f40G2Q-No-L. |
| 1.3.6.1.4.1.4756.20.690.20.1 | Rowf40G2QEntry | not-accessible | current | An entry containing management information applicable to a particular local FRM220-40G-2Q Line Card. |
| 1.3.6.1.4.1.4756.20.690.20.1.1 | Columnf40G2QChassisIndex | read-only | current | A unique value for each local card. It is the chassis location number. |
| 1.3.6.1.4.1.4756.20.690.20.1.2 | Columnf40G2QSlotIndex | read-only | current | A unique value for each local card. It is the slot location number. |
| 1.3.6.1.4.1.4756.20.690.20.1.3 | Columnf40G2QCardHWVer | read-only | current | Local FRM220-40G-2Q Line Card hardware version x.xxx |
| 1.3.6.1.4.1.4756.20.690.20.1.4 | Columnf40G2QCardFWVer | read-only | current | Local FRM220-40G-2Q Line Card firmware version x.xxx |
| 1.3.6.1.4.1.4756.20.690.20.1.5 | Columnf40G2QCardCPLDVer | read-only | current | Local FRM220-40G-2Q Line Card CPLD version x.xxx |
| 1.3.6.1.4.1.4756.20.690.20.1.6 | Columnf40G2QCardFPGAVer | read-only | current | Local FRM220-40G-2Q Line Card FPGA version x.xxx |
| 1.3.6.1.4.1.4756.20.690.20.1.7 | Columnf40G2QPortReset | read-write | current | Local FRM220-40G-2Q Line Card Port Reset feature: 0:Inactive 1:Active |
| 1.3.6.1.4.1.4756.20.690.20.1.8 | Columnf40G2QSetDefault | read-write | current | Local FRM220-40G-2Q Line Card Set to Default function: 0:Inactive 1:Active |
| 1.3.6.1.4.1.4756.20.690.20.1.9 | Columnf40G2QQSFP11Present | read-only | current | Local FRM220-40G-2Q Line Card QSFP 1-1 Fiber Port Present: 0:NO 1:YES |
| 1.3.6.1.4.1.4756.20.690.20.1.10 | Columnf40G2QQSFP12Present | read-only | current | Local FRM220-40G-2Q Line Card QSFP 1-2 Fiber Port Present: 0:NO 1:YES |
| 1.3.6.1.4.1.4756.20.690.20.1.11 | Columnf40G2QQSFP13Present | read-only | current | Local FRM220-40G-2Q Line Card QSFP 1-3 Fiber Port Present: 0:NO 1:YES |
| 1.3.6.1.4.1.4756.20.690.20.1.12 | Columnf40G2QQSFP14Present | read-only | current | Local FRM220-40G-2Q Line Card QSFP 1-4 Fiber Port Present: 0:NO 1:YES |
| 1.3.6.1.4.1.4756.20.690.20.1.13 | Columnf40G2QQSFP21Present | read-only | current | Local FRM220-40G-2Q Line Card QSFP 2-1 Fiber Port Present: 0:NO 1:YES |
| 1.3.6.1.4.1.4756.20.690.20.1.14 | Columnf40G2QQSFP22Present | read-only | current | Local FRM220-40G-2Q Line Card QSFP 2-2 Fiber Port Present: 0:NO 1:YES |
| 1.3.6.1.4.1.4756.20.690.20.1.15 | Columnf40G2QQSFP23Present | read-only | current | Local FRM220-40G-2Q Line Card QSFP 2-3 Fiber Port Present: 0:NO 1:YES |
| 1.3.6.1.4.1.4756.20.690.20.1.16 | Columnf40G2QQSFP24Present | read-only | current | Local FRM220-40G-2Q Line Card QSFP 2-4 Fiber Port Present: 0:NO 1:YES |
| 1.3.6.1.4.1.4756.20.690.20.1.17 | Columnf40G2QQSFP11DDM | read-only | current | Local FRM220-40G-2Q Line Card QSFP 1-1 Fiber Port Digital Diagnostic Monitoring (DDM): 0:NO 1:YES |
| 1.3.6.1.4.1.4756.20.690.20.1.18 | Columnf40G2QQSFP12DDM | read-only | current | Local FRM220-40G-2Q Line Card QSFP 1-2 Fiber Port Digital Diagnostic Monitoring (DDM): 0:NO 1:YES |
| 1.3.6.1.4.1.4756.20.690.20.1.19 | Columnf40G2QQSFP13DDM | read-only | current | Local FRM220-40G-2Q Line Card QSFP 1-3 Fiber Port Digital Diagnostic Monitoring (DDM): 0:NO 1:YES |
| 1.3.6.1.4.1.4756.20.690.20.1.20 | Columnf40G2QQSFP14DDM | read-only | current | Local FRM220-40G-2Q Line Card QSFP 1-4 Fiber Port Digital Diagnostic Monitoring (DDM): 0:NO 1:YES |
| 1.3.6.1.4.1.4756.20.690.20.1.21 | Columnf40G2QQSFP21DDM | read-only | current | Local FRM220-40G-2Q Line Card QSFP 2-1 Fiber Port Digital Diagnostic Monitoring (DDM): 0:NO 1:YES |
| 1.3.6.1.4.1.4756.20.690.20.1.22 | Columnf40G2QQSFP22DDM | read-only | current | Local FRM220-40G-2Q Line Card QSFP 2-2 Fiber Port Digital Diagnostic Monitoring (DDM): 0:NO 1:YES |
| 1.3.6.1.4.1.4756.20.690.20.1.23 | Columnf40G2QQSFP23DDM | read-only | current | Local FRM220-40G-2Q Line Card QSFP 2-3 Fiber Port Digital Diagnostic Monitoring (DDM): 0:NO 1:YES |
| 1.3.6.1.4.1.4756.20.690.20.1.24 | Columnf40G2QQSFP24DDM | read-only | current | Local FRM220-40G-2Q Line Card QSFP 2-4 Fiber Port Digital Diagnostic Monitoring (DDM): 0:NO 1:YES |
| 1.3.6.1.4.1.4756.20.690.20.1.25 | Columnf40G2QQSFP11Link | read-only | current | Local FRM220-40G-2Q Line Card QSFP 1-1 Fiber Port Link Status: 0:Down 1:Up |
| 1.3.6.1.4.1.4756.20.690.20.1.26 | Columnf40G2QQSFP12Link | read-only | current | Local FRM220-40G-2Q Line Card QSFP 1-2 Fiber Port Link Status: 0:Down 1:Up |
| 1.3.6.1.4.1.4756.20.690.20.1.27 | Columnf40G2QQSFP13Link | read-only | current | Local FRM220-40G-2Q Line Card QSFP 1-3 Fiber Port Link Status: 0:Down 1:Up |
| 1.3.6.1.4.1.4756.20.690.20.1.28 | Columnf40G2QQSFP14Link | read-only | current | Local FRM220-40G-2Q Line Card QSFP 1-4 Fiber Port Link Status: 0:Down 1:Up |
| 1.3.6.1.4.1.4756.20.690.20.1.29 | Columnf40G2QQSFP21Link | read-only | current | Local FRM220-40G-2Q Line Card QSFP 2-1 Fiber Port Link Status: 0:Down 1:Up |
| 1.3.6.1.4.1.4756.20.690.20.1.30 | Columnf40G2QQSFP22Link | read-only | current | Local FRM220-40G-2Q Line Card QSFP 2-2 Fiber Port Link Status: 0:Down 1:Up |
| 1.3.6.1.4.1.4756.20.690.20.1.31 | Columnf40G2QQSFP23Link | read-only | current | Local FRM220-40G-2Q Line Card QSFP 2-3 Fiber Port Link Status: 0:Down 1:Up |
| 1.3.6.1.4.1.4756.20.690.20.1.32 | Columnf40G2QQSFP24Link | read-only | current | Local FRM220-40G-2Q Line Card QSFP 2-4 Fiber Port Link Status: 0:Down 1:Up |
| 1.3.6.1.4.1.4756.20.690.20.1.33 | Columnf40G2QQSFP11CDRLock | read-only | current | Local FRM220-40G-2Q Line Card QSFP 1-1 Fiber Port CDR Lock Status: 0:Not Locked 1:Locked |
| 1.3.6.1.4.1.4756.20.690.20.1.34 | Columnf40G2QQSFP12CDRLock | read-only | current | Local FRM220-40G-2Q Line Card QSFP 1-2 Fiber Port CDR Lock Status: 0:Not Locked 1:Locked |
| 1.3.6.1.4.1.4756.20.690.20.1.35 | Columnf40G2QQSFP13CDRLock | read-only | current | Local FRM220-40G-2Q Line Card QSFP 1-3 Fiber Port CDR Lock Status: 0:Not Locked 1:Locked |
| 1.3.6.1.4.1.4756.20.690.20.1.36 | Columnf40G2QQSFP14CDRLock | read-only | current | Local FRM220-40G-2Q Line Card QSFP 1-4 Fiber Port CDR Lock Status: 0:Not Locked 1:Locked |
| 1.3.6.1.4.1.4756.20.690.20.1.37 | Columnf40G2QQSFP21CDRLock | read-only | current | Local FRM220-40G-2Q Line Card QSFP 2-1 Fiber Port CDR Lock Status: 0:Not Locked 1:Locked |
| 1.3.6.1.4.1.4756.20.690.20.1.38 | Columnf40G2QQSFP22CDRLock | read-only | current | Local FRM220-40G-2Q Line Card QSFP 2-2 Fiber Port CDR Lock Status: 0:Not Locked 1:Locked |
| 1.3.6.1.4.1.4756.20.690.20.1.39 | Columnf40G2QQSFP23CDRLock | read-only | current | Local FRM220-40G-2Q Line Card QSFP 2-3 Fiber Port CDR Lock Status: 0:Not Locked 1:Locked |
| 1.3.6.1.4.1.4756.20.690.20.1.40 | Columnf40G2QQSFP24CDRLock | read-only | current | Local FRM220-40G-2Q Line Card QSFP 2-4 Fiber Port CDR Lock Status: 0:Not Locked 1:Locked |
| 1.3.6.1.4.1.4756.20.690.20.1.41 | Columnf40G2QQSFP11TxFault | read-only | current | Local FRM220-40G-2Q Line Card QSFP 1-1 Fiber Port Transmit Fault Status: 0:Normal 1:Failure |
| 1.3.6.1.4.1.4756.20.690.20.1.42 | Columnf40G2QQSFP12TxFault | read-only | current | Local FRM220-40G-2Q Line Card QSFP 1-2 Fiber Port Transmit Fault Status: 0:Normal 1:Failure |
| 1.3.6.1.4.1.4756.20.690.20.1.43 | Columnf40G2QQSFP13TxFault | read-only | current | Local FRM220-40G-2Q Line Card QSFP 1-3 Fiber Port Transmit Fault Status: 0:Normal 1:Failure |
| 1.3.6.1.4.1.4756.20.690.20.1.44 | Columnf40G2QQSFP14TxFault | read-only | current | Local FRM220-40G-2Q Line Card QSFP 1-4 Fiber Port Transmit Fault Status: 0:Normal 1:Failure |
| 1.3.6.1.4.1.4756.20.690.20.1.45 | Columnf40G2QQSFP21TxFault | read-only | current | Local FRM220-40G-2Q Line Card QSFP 2-1 Fiber Port Transmit Fault Status: 0:Normal 1:Failure |
| 1.3.6.1.4.1.4756.20.690.20.1.46 | Columnf40G2QQSFP22TxFault | read-only | current | Local FRM220-40G-2Q Line Card QSFP 2-2 Fiber Port Transmit Fault Status: 0:Normal 1:Failure |
| 1.3.6.1.4.1.4756.20.690.20.1.47 | Columnf40G2QQSFP23TxFault | read-only | current | Local FRM220-40G-2Q Line Card QSFP 2-3 Fiber Port Transmit Fault Status: 0:Normal 1:Failure |
| 1.3.6.1.4.1.4756.20.690.20.1.48 | Columnf40G2QQSFP24TxFault | read-only | current | Local FRM220-40G-2Q Line Card QSFP 2-4 Fiber Port Transmit Fault Status: 0:Normal 1:Failure |
| 1.3.6.1.4.1.4756.20.690.20.1.49 | Columnf40G2QPortActive | read-write | current | Local FRM220-40G-2Q Line Card Active: 0:Disable 1:Enable |
| 1.3.6.1.4.1.4756.20.690.20.1.50 | Columnf40G2QDataRateSts | read-only | current | Local FRM220-40G-2Q Line Card Data Rate Status. |
| 1.3.6.1.4.1.4756.20.690.20.1.51 | Columnf40G2QDataRate | read-write | current | Local FRM220-40G-2Q Line Card Data Rate setting: 0:Ethernet 10GE |
| 1.3.6.1.4.1.4756.20.690.20.1.52 | Columnf40G2QQSFP1LBT | read-write | current | Local FRM220-40G-2Q Line Card QSFP 1 LoopBack Test function setting: 0:Disable 1:Enable |
| 1.3.6.1.4.1.4756.20.690.20.1.53 | Columnf40G2QQSFP2LBT | read-write | current | Local FRM220-40G-2Q Line Card QSFP 2 LoopBack Test function setting: 0:Disable 1:Enable |
| 1.3.6.1.4.1.4756.20.690.20.1.54 | Columnf40G2QQSFPLBT | read-write | current | Local FRM220-40G-2Q Line Card both of QSFP 1 and QSFP 2 LoopBack Test function setting: 0:Disable 1:Enable |
| 1.3.6.1.4.1.4756.20.690.20.1.55 | Columnf40G2QQSFP1LFP | read-write | current | Local FRM220-40G-2Q Line Card QSFP 1 Link Fault Pass-Through setting: 0:Disable 1:Enable |
| 1.3.6.1.4.1.4756.20.690.20.1.56 | Columnf40G2QQSFP11LFP | read-write | current | Local FRM220-40G-2Q Line Card QSFP 1-1 Link Fault Pass-Through setting: 0:Disable 1:Enable |
| 1.3.6.1.4.1.4756.20.690.20.1.57 | Columnf40G2QQSFP12LFP | read-write | current | Local FRM220-40G-2Q Line Card QSFP 1-2 Link Fault Pass-Through setting: 0:Disable 1:Enable |
| 1.3.6.1.4.1.4756.20.690.20.1.58 | Columnf40G2QQSFP13LFP | read-write | current | Local FRM220-40G-2Q Line Card QSFP 1-3 Link Fault Pass-Through setting: 0:Disable 1:Enable |
| 1.3.6.1.4.1.4756.20.690.20.1.59 | Columnf40G2QQSFP14LFP | read-write | current | Local FRM220-40G-2Q Line Card QSFP 1-4 Link Fault Pass-Through setting: 0:Disable 1:Enable |
| 1.3.6.1.4.1.4756.20.690.20.1.60 | Columnf40G2QQSFP2LFP | read-write | current | Local FRM220-40G-2Q Line Card QSFP 2 Link Fault Pass-Through setting: 0:Disable 1:Enable |
| 1.3.6.1.4.1.4756.20.690.20.1.61 | Columnf40G2QQSFP21LFP | read-write | current | Local FRM220-40G-2Q Line Card QSFP 2-1 Link Fault Pass-Through setting: 0:Disable 1:Enable |
| 1.3.6.1.4.1.4756.20.690.20.1.62 | Columnf40G2QQSFP22LFP | read-write | current | Local FRM220-40G-2Q Line Card QSFP 2-2 Link Fault Pass-Through setting: 0:Disable 1:Enable |
| 1.3.6.1.4.1.4756.20.690.20.1.63 | Columnf40G2QQSFP23LFP | read-write | current | Local FRM220-40G-2Q Line Card QSFP 2-3 Link Fault Pass-Through setting: 0:Disable 1:Enable |
| 1.3.6.1.4.1.4756.20.690.20.1.64 | Columnf40G2QQSFP24LFP | read-write | current | Local FRM220-40G-2Q Line Card QSFP 2-4 Link Fault Pass-Through setting: 0:Disable 1:Enable |
| 1.3.6.1.4.1.4756.20.690.20.1.65 | Columnf40G2QQSFP11LinkAlm | read-write | current | Local FRM220-40G-2Q Line Card QSFP 1-1 Link Alarm setting: 0:Disable 1:Enable |
| 1.3.6.1.4.1.4756.20.690.20.1.66 | Columnf40G2QQSFP12LinkAlm | read-write | current | Local FRM220-40G-2Q Line Card QSFP 1-2 Link Alarm setting: 0:Disable 1:Enable |
| 1.3.6.1.4.1.4756.20.690.20.1.67 | Columnf40G2QQSFP13LinkAlm | read-write | current | Local FRM220-40G-2Q Line Card QSFP 1-3 Link Alarm setting: 0:Disable 1:Enable |
| 1.3.6.1.4.1.4756.20.690.20.1.68 | Columnf40G2QQSFP14LinkAlm | read-write | current | Local FRM220-40G-2Q Line Card QSFP 1-4 Link Alarm setting: 0:Disable 1:Enable |
| 1.3.6.1.4.1.4756.20.690.20.1.69 | Columnf40G2QQSFP21LinkAlm | read-write | current | Local FRM220-40G-2Q Line Card QSFP 2-1 Link Alarm setting: 0:Disable 1:Enable |
| 1.3.6.1.4.1.4756.20.690.20.1.70 | Columnf40G2QQSFP22LinkAlm | read-write | current | Local FRM220-40G-2Q Line Card QSFP 2-2 Link Alarm setting: 0:Disable 1:Enable |
| 1.3.6.1.4.1.4756.20.690.20.1.71 | Columnf40G2QQSFP23LinkAlm | read-write | current | Local FRM220-40G-2Q Line Card QSFP 2-3 Link Alarm setting: 0:Disable 1:Enable |
| 1.3.6.1.4.1.4756.20.690.20.1.72 | Columnf40G2QQSFP24LinkAlm | read-write | current | Local FRM220-40G-2Q Line Card QSFP 2-4 Link Alarm setting: 0:Disable 1:Enable |
| 1.3.6.1.4.1.4756.20.690.20.1.73 | Columnf40G2QQSFP11LockAlm | read-write | current | Local FRM220-40G-2Q Line Card QSFP 1-1 CDR Lock Alarm setting: 0:Disable 1:Enable |
| 1.3.6.1.4.1.4756.20.690.20.1.74 | Columnf40G2QQSFP12LockAlm | read-write | current | Local FRM220-40G-2Q Line Card QSFP 1-2 CDR Lock Alarm setting: 0:Disable 1:Enable |
| 1.3.6.1.4.1.4756.20.690.20.1.75 | Columnf40G2QQSFP13LockAlm | read-write | current | Local FRM220-40G-2Q Line Card QSFP 1-3 CDR Lock Alarm setting: 0:Disable 1:Enable |
| 1.3.6.1.4.1.4756.20.690.20.1.76 | Columnf40G2QQSFP14LockAlm | read-write | current | Local FRM220-40G-2Q Line Card QSFP 1-4 CDR Lock Alarm setting: 0:Disable 1:Enable |
| 1.3.6.1.4.1.4756.20.690.20.1.77 | Columnf40G2QQSFP21LockAlm | read-write | current | Local FRM220-40G-2Q Line Card QSFP 2-1 CDR Lock Alarm setting: 0:Disable 1:Enable |
| 1.3.6.1.4.1.4756.20.690.20.1.78 | Columnf40G2QQSFP22LockAlm | read-write | current | Local FRM220-40G-2Q Line Card QSFP 2-2 CDR Lock Alarm setting: 0:Disable 1:Enable |
| 1.3.6.1.4.1.4756.20.690.20.1.79 | Columnf40G2QQSFP23LockAlm | read-write | current | Local FRM220-40G-2Q Line Card QSFP 2-3 CDR Lock Alarm setting: 0:Disable 1:Enable |
| 1.3.6.1.4.1.4756.20.690.20.1.80 | Columnf40G2QQSFP24LockAlm | read-write | current | Local FRM220-40G-2Q Line Card QSFP 2-4 CDR Lock Alarm setting: 0:Disable 1:Enable |
| 1.3.6.1.4.1.4756.20.690.20.1.81 | Columnf40G2QQSFP11TxFaultAlm | read-write | current | Local FRM220-40G-2Q Line Card QSFP 1-1 Transmit Fault Alarm setting: 0:Disable 1:Enable |
| 1.3.6.1.4.1.4756.20.690.20.1.82 | Columnf40G2QQSFP12TxFaultAlm | read-write | current | Local FRM220-40G-2Q Line Card QSFP 1-2 Transmit Fault Alarm setting: 0:Disable 1:Enable |
| 1.3.6.1.4.1.4756.20.690.20.1.83 | Columnf40G2QQSFP13TxFaultAlm | read-write | current | Local FRM220-40G-2Q Line Card QSFP 1-3 Transmit Fault Alarm setting: 0:Disable 1:Enable |
| 1.3.6.1.4.1.4756.20.690.20.1.84 | Columnf40G2QQSFP14TxFaultAlm | read-write | current | Local FRM220-40G-2Q Line Card QSFP 1-4 Transmit Fault Alarm setting: 0:Disable 1:Enable |
| 1.3.6.1.4.1.4756.20.690.20.1.85 | Columnf40G2QQSFP21TxFaultAlm | read-write | current | Local FRM220-40G-2Q Line Card QSFP 2-1 Transmit Fault Alarm setting: 0:Disable 1:Enable |
| 1.3.6.1.4.1.4756.20.690.20.1.86 | Columnf40G2QQSFP22TxFaultAlm | read-write | current | Local FRM220-40G-2Q Line Card QSFP 2-2 Transmit Fault Alarm setting: 0:Disable 1:Enable |
| 1.3.6.1.4.1.4756.20.690.20.1.87 | Columnf40G2QQSFP23TxFaultAlm | read-write | current | Local FRM220-40G-2Q Line Card QSFP 2-3 Transmit Fault Alarm setting: 0:Disable 1:Enable |
| 1.3.6.1.4.1.4756.20.690.20.1.88 | Columnf40G2QQSFP24TxFaultAlm | read-write | current | Local FRM220-40G-2Q Line Card QSFP 2-4 Transmit Fault Alarm setting: 0:Disable 1:Enable |
| 1.3.6.1.4.1.4756.20.690.20.1.89 | Columnf40G2QQSFP1VendorName | read-only | current | Local FRM220-40G-2Q Line Card QSFP 1 Vender Name. |
| 1.3.6.1.4.1.4756.20.690.20.1.90 | Columnf40G2QQSFP1PartNo | read-only | current | Local FRM220-40G-2Q Line Card QSFP 1 Part Number. |
| 1.3.6.1.4.1.4756.20.690.20.1.91 | Columnf40G2QQSFP1OpticalType | read-only | current | Local FRM220-40G-2Q Line Card QSFP 1 Optical Type: 0:Multi 1:Single 2:Unknown 3:N/A |
| 1.3.6.1.4.1.4756.20.690.20.1.92 | Columnf40G2QQSFP1WaveLength1 | read-only | current | Local FRM220-40G-2Q Line Card QSFP 1 Wave Length 1. |
| 1.3.6.1.4.1.4756.20.690.20.1.93 | Columnf40G2QQSFP1WaveLength2 | read-only | current | Local FRM220-40G-2Q Line Card QSFP 1 Wave Length 2. |
| 1.3.6.1.4.1.4756.20.690.20.1.94 | Columnf40G2QQSFP1LinkLength | read-only | current | Local FRM220-40G-2Q Line Card QSFP 1 Link Length. |
| 1.3.6.1.4.1.4756.20.690.20.1.95 | Columnf40G2QQSFP1Temp | read-only | current | Local FRM220-40G-2Q Line Card QSFP 1 Temperature. |
| 1.3.6.1.4.1.4756.20.690.20.1.96 | Columnf40G2QQSFP1SupplyVol | read-only | current | Local FRM220-40G-2Q Line Card QSFP 1 Supply Voltage. |
| 1.3.6.1.4.1.4756.20.690.20.1.97 | Columnf40G2QQSFP11TxPower | read-only | current | Local FRM220-40G-2Q Line Card QSFP 1-1 Transmit Power. |
| 1.3.6.1.4.1.4756.20.690.20.1.98 | Columnf40G2QQSFP11RxPower | read-only | current | Local FRM220-40G-2Q Line Card QSFP 1-1 Receive Power. |
| 1.3.6.1.4.1.4756.20.690.20.1.99 | Columnf40G2QQSFP11TxLaserBias | read-only | current | Local FRM220-40G-2Q Line Card QSFP 1-1 Transmit Laser BIAS. |
| 1.3.6.1.4.1.4756.20.690.20.1.100 | Columnf40G2QQSFP12TxPower | read-only | current | Local FRM220-40G-2Q Line Card QSFP 1-2 Transmit Power. |
| 1.3.6.1.4.1.4756.20.690.20.1.101 | Columnf40G2QQSFP12RxPower | read-only | current | Local FRM220-40G-2Q Line Card QSFP 1-2 Receive Power. |
| 1.3.6.1.4.1.4756.20.690.20.1.102 | Columnf40G2QQSFP12TxLaserBias | read-only | current | Local FRM220-40G-2Q Line Card QSFP 1-2 Transmit Laser BIAS. |
| 1.3.6.1.4.1.4756.20.690.20.1.103 | Columnf40G2QQSFP13TxPower | read-only | current | Local FRM220-40G-2Q Line Card QSFP 1-3 Transmit Power. |
| 1.3.6.1.4.1.4756.20.690.20.1.104 | Columnf40G2QQSFP13RxPower | read-only | current | Local FRM220-40G-2Q Line Card QSFP 1-3 Receive Power. |
| 1.3.6.1.4.1.4756.20.690.20.1.105 | Columnf40G2QQSFP13TxLaserBias | read-only | current | Local FRM220-40G-2Q Line Card QSFP 1-3 Transmit Laser BIAS. |
| 1.3.6.1.4.1.4756.20.690.20.1.106 | Columnf40G2QQSFP14TxPower | read-only | current | Local FRM220-40G-2Q Line Card QSFP 1-4 Transmit Power. |
| 1.3.6.1.4.1.4756.20.690.20.1.107 | Columnf40G2QQSFP14RxPower | read-only | current | Local FRM220-40G-2Q Line Card QSFP 1-4 Receive Power. |
| 1.3.6.1.4.1.4756.20.690.20.1.108 | Columnf40G2QQSFP14TxLaserBias | read-only | current | Local FRM220-40G-2Q Line Card QSFP 1-4 Transmit Laser BIAS. |
| 1.3.6.1.4.1.4756.20.690.20.1.109 | Columnf40G2QQSFP2VendorName | read-only | current | Local FRM220-40G-2Q Line Card QSFP 2 Vender Name. |
| 1.3.6.1.4.1.4756.20.690.20.1.110 | Columnf40G2QQSFP2PartNo | read-only | current | Local FRM220-40G-2Q Line Card QSFP 2 Part Number. |
| 1.3.6.1.4.1.4756.20.690.20.1.111 | Columnf40G2QQSFP2OpticalType | read-only | current | Local FRM220-40G-2Q Line Card QSFP 2 Optical Type: 0:Multi 1:Single 2:Unknown 3:N/A |
| 1.3.6.1.4.1.4756.20.690.20.1.112 | Columnf40G2QQSFP2WaveLength1 | read-only | current | Local FRM220-40G-2Q Line Card QSFP 2 Wave Length 1. |
| 1.3.6.1.4.1.4756.20.690.20.1.113 | Columnf40G2QQSFP2WaveLength2 | read-only | current | Local FRM220-40G-2Q Line Card QSFP 2 Wave Length 2. |
| 1.3.6.1.4.1.4756.20.690.20.1.114 | Columnf40G2QQSFP2LinkLength | read-only | current | Local FRM220-40G-2Q Line Card QSFP 2 Link Length. |
| 1.3.6.1.4.1.4756.20.690.20.1.115 | Columnf40G2QQSFP2Temp | read-only | current | Local FRM220-40G-2Q Line Card QSFP 2 Temperature. |
| 1.3.6.1.4.1.4756.20.690.20.1.116 | Columnf40G2QQSFP2SupplyVol | read-only | current | Local FRM220-40G-2Q Line Card QSFP 2 Supply Voltage. |
| 1.3.6.1.4.1.4756.20.690.20.1.117 | Columnf40G2QQSFP21TxPower | read-only | current | Local FRM220-40G-2Q Line Card QSFP 2-1 Transmit Power. |
| 1.3.6.1.4.1.4756.20.690.20.1.118 | Columnf40G2QQSFP21RxPower | read-only | current | Local FRM220-40G-2Q Line Card QSFP 2-1 Receive Power. |
| 1.3.6.1.4.1.4756.20.690.20.1.119 | Columnf40G2QQSFP21TxLaserBias | read-only | current | Local FRM220-40G-2Q Line Card QSFP 2-1 Transmit Laser BIAS. |
| 1.3.6.1.4.1.4756.20.690.20.1.120 | Columnf40G2QQSFP22TxPower | read-only | current | Local FRM220-40G-2Q Line Card QSFP 2-2 Transmit Power. |
| 1.3.6.1.4.1.4756.20.690.20.1.121 | Columnf40G2QQSFP22RxPower | read-only | current | Local FRM220-40G-2Q Line Card QSFP 2-2 Receive Power. |
| 1.3.6.1.4.1.4756.20.690.20.1.122 | Columnf40G2QQSFP22TxLaserBias | read-only | current | Local FRM220-40G-2Q Line Card QSFP 2-2 Transmit Laser BIAS. |
| 1.3.6.1.4.1.4756.20.690.20.1.123 | Columnf40G2QQSFP23TxPower | read-only | current | Local FRM220-40G-2Q Line Card QSFP 2-3 Transmit Power. |
| 1.3.6.1.4.1.4756.20.690.20.1.124 | Columnf40G2QQSFP23RxPower | read-only | current | Local FRM220-40G-2Q Line Card QSFP 2-3 Receive Power. |
| 1.3.6.1.4.1.4756.20.690.20.1.125 | Columnf40G2QQSFP23TxLaserBias | read-only | current | Local FRM220-40G-2Q Line Card QSFP 2-3 Transmit Laser BIAS. |
| 1.3.6.1.4.1.4756.20.690.20.1.126 | Columnf40G2QQSFP24TxPower | read-only | current | Local FRM220-40G-2Q Line Card QSFP 2-4 Transmit Power. |
| 1.3.6.1.4.1.4756.20.690.20.1.127 | Columnf40G2QQSFP24RxPower | read-only | current | Local FRM220-40G-2Q Line Card QSFP 2-4 Receive Power. |
| 1.3.6.1.4.1.4756.20.690.20.1.128 | Columnf40G2QQSFP24TxLaserBias | read-only | current | Local FRM220-40G-2Q Line Card QSFP 2-4 Transmit Laser BIAS. |
| 1.3.6.1.4.1.4756.20.700 | Nodef10GMUXLocalCards | |||
| 1.3.6.1.4.1.4756.20.700.20 | Tablef10GMUXTable | not-accessible | current | A list of local FRM220-TM-10GMUX Line Card entries. The number of entries is f10GMUX-No-L. |
| 1.3.6.1.4.1.4756.20.700.20.1 | Rowf10GMUXEntry | not-accessible | current | An entry containing management information applicable to a particular local FRM220-TM-10GMUX Line Card. |
| 1.3.6.1.4.1.4756.20.700.20.1.1 | Columnf10GMUXChassisIndexLocal | read-only | current | A unique value for each local card. It is the chassis location number. |
| 1.3.6.1.4.1.4756.20.700.20.1.2 | Columnf10GMUXSlotIndexLocal | read-only | current | A unique value for each local card. It is the slot location number. |
| 1.3.6.1.4.1.4756.20.700.20.1.3 | Columnf10GMUXCardHWVerLocal | read-only | current | Local FRM220-TM-10GMUX Line Card hardware version x.xxx |
| 1.3.6.1.4.1.4756.20.700.20.1.4 | Columnf10GMUXCardFWVerLocal | read-only | current | Local FRM220-TM-10GMUX Line Card firmware version x.xxx |
| 1.3.6.1.4.1.4756.20.700.20.1.5 | Columnf10GMUXCardCPLDVerLocal | read-only | current | Local FRM220-TM-10GMUX Line Card CPLD version x.xxx |
| 1.3.6.1.4.1.4756.20.700.20.1.6 | Columnf10GMUXCardFPGAVerLocal | read-only | current | Local FRM220-TM-10GMUX Line Card FPGA version x.xxx |
| 1.3.6.1.4.1.4756.20.700.20.1.7 | Columnf10GMUXPortResetLocal | read-write | current | Local FRM220-TM-10GMUX card to reset mode: 0:Off 1:Action |
| 1.3.6.1.4.1.4756.20.700.20.1.8 | Columnf10GMUXSetToDefaultLocal | read-write | current | Local FRM220-TM-10GMUX card set to default : 0:Off 1:Action |
| 1.3.6.1.4.1.4756.20.700.20.1.9 | Columnf10GMUXLineExistLocal | read-only | current | Local FRM220-TM-10GMUX card Line Exist status: 0:Empty 1:Exist |
| 1.3.6.1.4.1.4756.20.700.20.1.10 | Columnf10GMUXCH1ExistLocal | read-only | current | Local FRM220-TM-10GMUX card CH1 Exist status: 0:Empty 1:Exist |
| 1.3.6.1.4.1.4756.20.700.20.1.11 | Columnf10GMUXCH2ExistLocal | read-only | current | Local FRM220-TM-10GMUX card CH2 Exist status: 0:Empty 1:Exist |
| 1.3.6.1.4.1.4756.20.700.20.1.12 | Columnf10GMUXCH3ExistLocal | read-only | current | Local FRM220-TM-10GMUX card CH3 Exist status: 0:Empty 1:Exist |
| 1.3.6.1.4.1.4756.20.700.20.1.13 | Columnf10GMUXCH4ExistLocal | read-only | current | Local FRM220-TM-10GMUX card CH4 Exist status: 0:Empty 1:Exist |
| 1.3.6.1.4.1.4756.20.700.20.1.14 | Columnf10GMUXCH5ExistLocal | read-only | current | Local FRM220-TM-10GMUX card CH5 Exist status: 0:Empty 1:Exist |
| 1.3.6.1.4.1.4756.20.700.20.1.15 | Columnf10GMUXCH6ExistLocal | read-only | current | Local FRM220-TM-10GMUX card CH6 Exist status: 0:Empty 1:Exist |
| 1.3.6.1.4.1.4756.20.700.20.1.16 | Columnf10GMUXCH7ExistLocal | read-only | current | Local FRM220-TM-10GMUX card CH7 Exist status: 0:Empty 1:Exist |
| 1.3.6.1.4.1.4756.20.700.20.1.17 | Columnf10GMUXLineLinkLocal | read-only | current | Local FRM220-TM-10GMUX card Line Link status: 0:Down 1:up |
| 1.3.6.1.4.1.4756.20.700.20.1.18 | Columnf10GMUXCH1LinkLocal | read-only | current | Local FRM220-TM-10GMUX card CH1 Link status: 0:Down 1:up |
| 1.3.6.1.4.1.4756.20.700.20.1.19 | Columnf10GMUXCH2LinkLocal | read-only | current | Local FRM220-TM-10GMUX card CH2 Link status: 0:Down 1:up |
| 1.3.6.1.4.1.4756.20.700.20.1.20 | Columnf10GMUXCH3LinkLocal | read-only | current | Local FRM220-TM-10GMUX card CH3 Link status: 0:Down 1:up |
| 1.3.6.1.4.1.4756.20.700.20.1.21 | Columnf10GMUXCH4LinkLocal | read-only | current | Local FRM220-TM-10GMUX card CH4 Link status: 0:Down 1:up |
| 1.3.6.1.4.1.4756.20.700.20.1.22 | Columnf10GMUXCH5LinkLocal | read-only | current | Local FRM220-TM-10GMUX card CH5 Link status: 0:Down 1:up |
| 1.3.6.1.4.1.4756.20.700.20.1.23 | Columnf10GMUXCH6LinkLocal | read-only | current | Local FRM220-TM-10GMUX card CH6 Link status: 0:Down 1:up |
| 1.3.6.1.4.1.4756.20.700.20.1.24 | Columnf10GMUXCH7LinkLocal | read-only | current | Local FRM220-TM-10GMUX card CH7 Link status: 0:Down 1:up |
| 1.3.6.1.4.1.4756.20.700.20.1.25 | Columnf10GMUXLineSyncLocal | read-only | current | Local FRM220-TM-10GMUX card Line Sync status: 0:No 1:Yes |
| 1.3.6.1.4.1.4756.20.700.20.1.26 | Columnf10GMUXCH1SyncLocal | read-only | current | Local FRM220-TM-10GMUX card CH1 Sync status: 0:No 1:Yes |
| 1.3.6.1.4.1.4756.20.700.20.1.27 | Columnf10GMUXCH2SyncLocal | read-only | current | Local FRM220-TM-10GMUX card CH2 Sync status: 0:No 1:Yes |
| 1.3.6.1.4.1.4756.20.700.20.1.28 | Columnf10GMUXCH3SyncLocal | read-only | current | Local FRM220-TM-10GMUX card CH3 Sync status: 0:No 1:Yes |
| 1.3.6.1.4.1.4756.20.700.20.1.29 | Columnf10GMUXCH4SyncLocal | read-only | current | Local FRM220-TM-10GMUX card CH4 Sync status: 0:Not Locked 1:Yes |
| 1.3.6.1.4.1.4756.20.700.20.1.30 | Columnf10GMUXCH5SyncLocal | read-only | current | Local FRM220-TM-10GMUX card CH5 Sync status: 0:No 1:Yes |
| 1.3.6.1.4.1.4756.20.700.20.1.31 | Columnf10GMUXCH6SyncLocal | read-only | current | Local FRM220-TM-10GMUX card CH6 Sync status: 0:No 1:Yes |
| 1.3.6.1.4.1.4756.20.700.20.1.32 | Columnf10GMUXCH7SyncLocal | read-only | current | Local FRM220-TM-10GMUX card CH7 Sync status: 0:no 1:yes |
| 1.3.6.1.4.1.4756.20.700.20.1.33 | Columnf10GMUXLineTxFaultLocal | read-only | current | Local FRM220-TM-10GMUX card Line Tx Fault status: 0:Normal 1:Failure |
| 1.3.6.1.4.1.4756.20.700.20.1.34 | Columnf10GMUXCH1TxFaultLocal | read-only | current | Local FRM220-TM-10GMUX card CH1 Tx Fault status: 0:Normal 1:Failure |
| 1.3.6.1.4.1.4756.20.700.20.1.35 | Columnf10GMUXCH2TxFaultLocal | read-only | current | Local FRM220-TM-10GMUX card CH2 Tx Fault status: 0:Normal 1:Failure |
| 1.3.6.1.4.1.4756.20.700.20.1.36 | Columnf10GMUXCH3TxFaultLocal | read-only | current | Local FRM220-TM-10GMUX card CH3 Tx Fault status: 0:Normal 1:Failure |
| 1.3.6.1.4.1.4756.20.700.20.1.37 | Columnf10GMUXCH4TxFaultLocal | read-only | current | Local FRM220-TM-10GMUX card CH4 Tx Fault status: 0:Normal 1:Failure |
| 1.3.6.1.4.1.4756.20.700.20.1.38 | Columnf10GMUXCH5TxFaultLocal | read-only | current | Local FRM220-TM-10GMUX card CH5 Tx Fault status: 0:Normal 1:Failure |
| 1.3.6.1.4.1.4756.20.700.20.1.39 | Columnf10GMUXCH6TxFaultLocal | read-only | current | Local FRM220-TM-10GMUX card CH6 Tx Fault status: 0:Normal 1:Failure |
| 1.3.6.1.4.1.4756.20.700.20.1.40 | Columnf10GMUXCH7TxFaultLocal | read-only | current | Local FRM220-TM-10GMUX card CH7 Tx Fault status: 0:Normal 1:Failure |
| 1.3.6.1.4.1.4756.20.700.20.1.41 | Columnf10GMUXLineDDLocal | read-only | current | Local FRM220-TM-10GMUX card Line DD status: 0:no 1:yes |
| 1.3.6.1.4.1.4756.20.700.20.1.42 | Columnf10GMUXCH1DDLocal | read-only | current | Local FRM220-TM-10GMUX card CH1 DD status: 0:no 1:yes |
| 1.3.6.1.4.1.4756.20.700.20.1.43 | Columnf10GMUXCH2DDLocal | read-only | current | Local FRM220-TM-10GMUX card CH2 DD status: 0:no 1:yes |
| 1.3.6.1.4.1.4756.20.700.20.1.44 | Columnf10GMUXCH3DDLocal | read-only | current | Local FRM220-TM-10GMUX card CH3 DD status: 0:no 1:yes |
| 1.3.6.1.4.1.4756.20.700.20.1.45 | Columnf10GMUXCH4DDLocal | read-only | current | Local FRM220-TM-10GMUX card CH4 DD status: 0:no 1:yes |
| 1.3.6.1.4.1.4756.20.700.20.1.46 | Columnf10GMUXCH5DDLocal | read-only | current | Local FRM220-TM-10GMUX card CH5 DD status: 0:no 1:yes |
| 1.3.6.1.4.1.4756.20.700.20.1.47 | Columnf10GMUXCH6DDLocal | read-only | current | Local FRM220-TM-10GMUX card CH6 DD status: 0:no 1:yes |
| 1.3.6.1.4.1.4756.20.700.20.1.48 | Columnf10GMUXCH7DDLocal | read-only | current | Local FRM220-TM-10GMUX card CH7 DD status: 0:no 1:yes |
| 1.3.6.1.4.1.4756.20.700.20.1.49 | Columnf10GMUXLineCounterLocal | read-only | current | FRM220-10GMUX cards Line Counter. |
| 1.3.6.1.4.1.4756.20.700.20.1.50 | Columnf10GMUXCH1CounterLocal | read-only | current | FRM220-10GMUX cards CH1 Counter. |
| 1.3.6.1.4.1.4756.20.700.20.1.51 | Columnf10GMUXCH2CounterLocal | read-only | current | FRM220-10GMUX cards CH2 Counter. |
| 1.3.6.1.4.1.4756.20.700.20.1.52 | Columnf10GMUXCH3CounterLocal | read-only | current | FRM220-10GMUX cards CH3 Counter. |
| 1.3.6.1.4.1.4756.20.700.20.1.53 | Columnf10GMUXCH4CounterLocal | read-only | current | FRM220-10GMUX cards CH4 Counter. |
| 1.3.6.1.4.1.4756.20.700.20.1.54 | Columnf10GMUXCH5CounterLocal | read-only | current | FRM220-10GMUX cards CH5 Counter. |
| 1.3.6.1.4.1.4756.20.700.20.1.55 | Columnf10GMUXCH6CounterLocal | read-only | current | FRM220-10GMUX cards CH6 Counter. |
| 1.3.6.1.4.1.4756.20.700.20.1.56 | Columnf10GMUXCH7CounterLocal | read-only | current | FRM220-10GMUX cards CH7 Counter. |
| 1.3.6.1.4.1.4756.20.700.20.1.57 | Columnf10GMUXLinePortActiveLocal | read-write | current | FRM220-10GMUX cards Line Port Active: 0:disable 1:enable |
| 1.3.6.1.4.1.4756.20.700.20.1.58 | Columnf10GMUXCH1PortActiveLocal | read-write | current | FRM220-10GMUX cards CH1 Port Active: 0:disable 1:enable |
| 1.3.6.1.4.1.4756.20.700.20.1.59 | Columnf10GMUXCH2PortActiveLocal | read-write | current | FRM220-10GMUX cards CH2 Port Active: 0:disable 1:enable |
| 1.3.6.1.4.1.4756.20.700.20.1.60 | Columnf10GMUXCH3PortActiveLocal | read-write | current | FRM220-10GMUX cards CH3 Port Active: 0:disable 1:enable |
| 1.3.6.1.4.1.4756.20.700.20.1.61 | Columnf10GMUXCH4PortActiveLocal | read-write | current | FRM220-10GMUX cards CH4 Port Active: 0:disable 1:enable |
| 1.3.6.1.4.1.4756.20.700.20.1.62 | Columnf10GMUXCH5PortActiveLocal | read-write | current | FRM220-10GMUX cards CH5 Port Active: 0:disable 1:enable |
| 1.3.6.1.4.1.4756.20.700.20.1.63 | Columnf10GMUXCH6PortActiveLocal | read-write | current | FRM220-10GMUX cards CH6 Port Active: 0:disable 1:enable |
| 1.3.6.1.4.1.4756.20.700.20.1.64 | Columnf10GMUXCH7PortActiveLocal | read-write | current | FRM220-10GMUX cards CH7 Port Active: 0:disable 1:enable |
| 1.3.6.1.4.1.4756.20.700.20.1.65 | Columnf10GMUXLineLFPLocal | read-write | current | Local FRM220-TM-10GMUX card Line Link Fault Pass Through: 0:Disable 1:Enable |
| 1.3.6.1.4.1.4756.20.700.20.1.66 | Columnf10GMUXCH1LFPLocal | read-write | current | Local FRM220-TM-10GMUX card CH1 Link Fault Pass Through: 0:Disable 1:Enable |
| 1.3.6.1.4.1.4756.20.700.20.1.67 | Columnf10GMUXCH2LFPLocal | read-write | current | Local FRM220-TM-10GMUX card CH2 Link Fault Pass Through: 0:Disable 1:Enable |
| 1.3.6.1.4.1.4756.20.700.20.1.68 | Columnf10GMUXCH3LFPLocal | read-write | current | Local FRM220-TM-10GMUX card CH3 Link Fault Pass Through: 0:Disable 1:Enable |
| 1.3.6.1.4.1.4756.20.700.20.1.69 | Columnf10GMUXCH4LFPLocal | read-write | current | Local FRM220-TM-10GMUX card CH4 Link Fault Pass Through: 0:Disable 1:Enable |
| 1.3.6.1.4.1.4756.20.700.20.1.70 | Columnf10GMUXCH5LFPLocal | read-write | current | Local FRM220-TM-10GMUX card CH5 Link Fault Pass Through: 0:Disable 1:Enable |
| 1.3.6.1.4.1.4756.20.700.20.1.71 | Columnf10GMUXCH6LFPLocal | read-write | current | Local FRM220-TM-10GMUX card CH6 Link Fault Pass Through: 0:Disable 1:Enable |
| 1.3.6.1.4.1.4756.20.700.20.1.72 | Columnf10GMUXCH7LFPLocal | read-write | current | Local FRM220-TM-10GMUX card CH7 Link Fault Pass Through: 0:Disable 1:Enable |
| 1.3.6.1.4.1.4756.20.700.20.1.73 | Columnf10GMUXLineALSLocal | read-write | current | Local FRM220-TM-10GMUX card Line Auto Laser Showdown: 0:Disable 1:Enable |
| 1.3.6.1.4.1.4756.20.700.20.1.74 | Columnf10GMUXCH1ALSLocal | read-write | current | Local FRM220-TM-10GMUX card CH1 Auto Laser Showdown: 0:Disable 1:Enable |
| 1.3.6.1.4.1.4756.20.700.20.1.75 | Columnf10GMUXCH2ALSLocal | read-write | current | Local FRM220-TM-10GMUX card CH2 Auto Laser Showdown: 0:Disable 1:Enable |
| 1.3.6.1.4.1.4756.20.700.20.1.76 | Columnf10GMUXCH3ALSLocal | read-write | current | Local FRM220-TM-10GMUX card CH3 Auto Laser Showdown: 0:Disable 1:Enable |
| 1.3.6.1.4.1.4756.20.700.20.1.77 | Columnf10GMUXCH4ALSLocal | read-write | current | Local FRM220-TM-10GMUX card CH4 Auto Laser Showdown: 0:Disable 1:Enable |
| 1.3.6.1.4.1.4756.20.700.20.1.78 | Columnf10GMUXCH5ALSLocal | read-write | current | Local FRM220-TM-10GMUX card CH5 Auto Laser Showdown: 0:Disable 1:Enable |
| 1.3.6.1.4.1.4756.20.700.20.1.79 | Columnf10GMUXCH6ALSLocal | read-write | current | Local FRM220-TM-10GMUX card CH6 Auto Laser Showdown: 0:Disable 1:Enable |
| 1.3.6.1.4.1.4756.20.700.20.1.80 | Columnf10GMUXCH7ALSLocal | read-write | current | Local FRM220-TM-10GMUX card CH7 Auto Laser Showdown: 0:Disable 1:Enable |
| 1.3.6.1.4.1.4756.20.700.20.1.81 | Columnf10GMUXCH1LoopbackLocal | read-write | current | Local FRM220-TM-10GMUX card CH1 Loopback: 0:Disable 1:Enable |
| 1.3.6.1.4.1.4756.20.700.20.1.82 | Columnf10GMUXCH2LoopbackLocal | read-write | current | Local FRM220-TM-10GMUX card CH2 Loopback: 0:Disable 1:Enable |
| 1.3.6.1.4.1.4756.20.700.20.1.83 | Columnf10GMUXCH3LoopbackLocal | read-write | current | Local FRM220-TM-10GMUX card CH3 Loopback: 0:Disable 1:Enable |
| 1.3.6.1.4.1.4756.20.700.20.1.84 | Columnf10GMUXCH4LoopbackLocal | read-write | current | Local FRM220-TM-10GMUX card CH4 Loopback: 0:Disable 1:Enable |
| 1.3.6.1.4.1.4756.20.700.20.1.85 | Columnf10GMUXCH5LoopbackLocal | read-write | current | Local FRM220-TM-10GMUX card CH5 Loopback: 0:Disable 1:Enable |
| 1.3.6.1.4.1.4756.20.700.20.1.86 | Columnf10GMUXCH6LoopbackLocal | read-write | current | Local FRM220-TM-10GMUX card CH6 Loopback: 0:Disable 1:Enable |
| 1.3.6.1.4.1.4756.20.700.20.1.87 | Columnf10GMUXCH7LoopbackLocal | read-write | current | Local FRM220-TM-10GMUX card CH7 Loopback: 0:Disable 1:Enable |
| 1.3.6.1.4.1.4756.20.700.20.1.88 | Columnf10GMUXAlarmStatusLocal | read-only | current | Local FRM220-TM-10GMUX card Alarm status: 0:Normal 1:Abmormal |
| 1.3.6.1.4.1.4756.20.700.20.1.89 | Columnf10GMUXLineTriggerLocal | read-write | current | FRM220-10GMUX cards Line Trigger: 0:disable 1:enable |
| 1.3.6.1.4.1.4756.20.700.20.1.90 | Columnf10GMUXCH1TriggerLocal | read-write | current | FRM220-10GMUX cards CH1 Trigger: 0:disable 1:enable |
| 1.3.6.1.4.1.4756.20.700.20.1.91 | Columnf10GMUXCH2TriggerLocal | read-write | current | FRM220-10GMUX cards CH2 Trigger: 0:disable 1:enable |
| 1.3.6.1.4.1.4756.20.700.20.1.92 | Columnf10GMUXCH3TriggerLocal | read-write | current | FRM220-10GMUX cards CH3 Trigger: 0:disable 1:enable |
| 1.3.6.1.4.1.4756.20.700.20.1.93 | Columnf10GMUXCH4TriggerLocal | read-write | current | FRM220-10GMUX cards CH4 Trigger: 0:disable 1:enable |
| 1.3.6.1.4.1.4756.20.700.20.1.94 | Columnf10GMUXCH5TriggerLocal | read-write | current | FRM220-10GMUX cards CH5 Trigger: 0:disable 1:enable |
| 1.3.6.1.4.1.4756.20.700.20.1.95 | Columnf10GMUXCH6TriggerLocal | read-write | current | FRM220-10GMUX cards CH6 Trigger: 0:disable 1:enable |
| 1.3.6.1.4.1.4756.20.700.20.1.96 | Columnf10GMUXCH7TriggerLocal | read-write | current | FRM220-10GMUX cards CH7 Trigger: 0:disable 1:enable |
| 1.3.6.1.4.1.4756.20.700.20.1.97 | Columnf10GMUXLineDDVendorLocal | read-only | current | Local FRM220-TM-10GMUX card Line D/D information: Vendor name |
| 1.3.6.1.4.1.4756.20.700.20.1.98 | Columnf10GMUXLineDDPartNoLocal | read-only | current | Local FRM220-TM-10GMUX card Line D/D information: Vendor part number |
| 1.3.6.1.4.1.4756.20.700.20.1.99 | Columnf10GMUXLineDDVendorSNLocal | read-only | current | Local FRM220-TM-10GMUX card Line D/D information: Vendor SN |
| 1.3.6.1.4.1.4756.20.700.20.1.100 | Columnf10GMUXLineDDFiberTypeLocal | read-only | current | Local FRM220-TM-10GMUX card Line D/D information: Fiber Type |
| 1.3.6.1.4.1.4756.20.700.20.1.101 | Columnf10GMUXLineDDWaveLenLocal | read-only | current | Local FRM220-TM-10GMUX card Line D/D information: Wave length |
| 1.3.6.1.4.1.4756.20.700.20.1.102 | Columnf10GMUXLineDDWaveLen2Local | read-only | current | Local FRM220-TM-10GMUX card Line D/D information: Wave length 2 |
| 1.3.6.1.4.1.4756.20.700.20.1.103 | Columnf10GMUXLineDDLinkLenLocal | read-only | current | Local FRM220-TM-10GMUX card Line D/D information: Link length |
| 1.3.6.1.4.1.4756.20.700.20.1.104 | Columnf10GMUXLineDDLenUnitLocal | read-only | current | Local FRM220-10GMUX card Line D/D information: Length Unit |
| 1.3.6.1.4.1.4756.20.700.20.1.105 | Columnf10GMUXLineDDRxSensLocal | read-only | current | Local FRM220-TM-10GMUX card Line D/D information: Rx Sensitivity |
| 1.3.6.1.4.1.4756.20.700.20.1.106 | Columnf10GMUXLineDDTxPWRLocal | read-only | current | Local FRM220-TM-10GMUX card Line D/D information: Tx power |
| 1.3.6.1.4.1.4756.20.700.20.1.107 | Columnf10GMUXLineDDRxPWRLocal | read-only | current | Local FRM220-TM-10GMUX card Line D/D information: Rx power |
| 1.3.6.1.4.1.4756.20.700.20.1.108 | Columnf10GMUXLineDDTempLocal | read-only | current | Local FRM220-TM-10GMUX card Line D/D information: Temperature in degree C |
| 1.3.6.1.4.1.4756.20.700.20.1.109 | Columnf10GMUXLineSupplyVolLocal | read-only | current | Local FRM220-TM-10GMUX card Line D/D information: SupplyVol |
| 1.3.6.1.4.1.4756.20.700.20.1.110 | Columnf10GMUXLineTxLaserBiasLocal | read-only | current | Local FRM220-TM-10GMUX card Line D/D information: Tx LaserBias |
| 1.3.6.1.4.1.4756.20.700.20.1.111 | Columnf10GMUXCH1DDVendorLocal | read-only | current | Local FRM220-TM-10GMUX card CH1 D/D information: Vendor name |
| 1.3.6.1.4.1.4756.20.700.20.1.112 | Columnf10GMUXCH1DDPartNoLocal | read-only | current | Local FRM220-TM-10GMUX card CH1 D/D information: Vendor part number |
| 1.3.6.1.4.1.4756.20.700.20.1.113 | Columnf10GMUXCH1DDVendorSNLocal | read-only | current | Local FRM220-TM-10GMUX card CH1 D/D information: Vendor SN |
| 1.3.6.1.4.1.4756.20.700.20.1.114 | Columnf10GMUXCH1DDFiberTypeLocal | read-only | current | Local FRM220-TM-10GMUX card CH1 D/D information: Fiber Type |
| 1.3.6.1.4.1.4756.20.700.20.1.115 | Columnf10GMUXCH1DDWaveLenLocal | read-only | current | Local FRM220-TM-10GMUX card CH1 D/D information: Wave length |
| 1.3.6.1.4.1.4756.20.700.20.1.116 | Columnf10GMUXCH1DDWaveLen2Local | read-only | current | Local FRM220-TM-10GMUX card CH1 D/D information: Wave length 2 |
| 1.3.6.1.4.1.4756.20.700.20.1.117 | Columnf10GMUXCH1DDLinkLenLocal | read-only | current | Local FRM220-TM-10GMUX card CH1 D/D information: Link length |
| 1.3.6.1.4.1.4756.20.700.20.1.118 | Columnf10GMUXCH1DDLenUnitLocal | read-only | current | Local FRM220-10GMUX card CH1 D/D information: Length Unit |
| 1.3.6.1.4.1.4756.20.700.20.1.119 | Columnf10GMUXCH1DDRxSensLocal | read-only | current | Local FRM220-TM-10GMUX card CH1 D/D information: Rx Sensitivity |
| 1.3.6.1.4.1.4756.20.700.20.1.120 | Columnf10GMUXCH1DDTxPWRLocal | read-only | current | Local FRM220-TM-10GMUX card CH1 D/D information: Tx power |
| 1.3.6.1.4.1.4756.20.700.20.1.121 | Columnf10GMUXCH1DDRxPWRLocal | read-only | current | Local FRM220-TM-10GMUX card CH1 D/D information: Rx power |
| 1.3.6.1.4.1.4756.20.700.20.1.122 | Columnf10GMUXCH1DDTempLocal | read-only | current | Local FRM220-TM-10GMUX card CH1 D/D information: Temperature in degree C |
| 1.3.6.1.4.1.4756.20.700.20.1.123 | Columnf10GMUXCH1SupplyVolLocal | read-only | current | Local FRM220-TM-10GMUX card CH1 D/D information: SupplyVol |
| 1.3.6.1.4.1.4756.20.700.20.1.124 | Columnf10GMUXCH1TxLaserBiasLocal | read-only | current | Local FRM220-TM-10GMUX card CH1 D/D information: Tx LaserBias |
| 1.3.6.1.4.1.4756.20.700.20.1.125 | Columnf10GMUXCH2DDVendorLocal | read-only | current | Local FRM220-TM-10GMUX card CH2 D/D information: Vendor name |
| 1.3.6.1.4.1.4756.20.700.20.1.126 | Columnf10GMUXCH2DDPartNoLocal | read-only | current | Local FRM220-TM-10GMUX card CH2 D/D information: Vendor part number |
| 1.3.6.1.4.1.4756.20.700.20.1.127 | Columnf10GMUXCH2DDVendorSNLocal | read-only | current | Local FRM220-TM-10GMUX card CH2 D/D information: Vendor SN |
| 1.3.6.1.4.1.4756.20.700.20.1.128 | Columnf10GMUXCH2DDFiberTypeLocal | read-only | current | Local FRM220-TM-10GMUX card CH2 D/D information: Fiber Type |
| 1.3.6.1.4.1.4756.20.700.20.1.129 | Columnf10GMUXCH2DDWaveLenLocal | read-only | current | Local FRM220-TM-10GMUX card CH2 D/D information: Wave length |
| 1.3.6.1.4.1.4756.20.700.20.1.130 | Columnf10GMUXCH2DDWaveLen2Local | read-only | current | Local FRM220-TM-10GMUX card CH2 D/D information: Wave length 2 |
| 1.3.6.1.4.1.4756.20.700.20.1.131 | Columnf10GMUXCH2DDLinkLenLocal | read-only | current | Local FRM220-TM-10GMUX card CH2 D/D information: Link length |
| 1.3.6.1.4.1.4756.20.700.20.1.132 | Columnf10GMUXCH2DDLenUnitLocal | read-only | current | Local FRM220-10GMUX card CH2 D/D information: Length Unit |
| 1.3.6.1.4.1.4756.20.700.20.1.133 | Columnf10GMUXCH2DDRxSensLocal | read-only | current | Local FRM220-TM-10GMUX card CH2 D/D information: Rx Sensitivity |
| 1.3.6.1.4.1.4756.20.700.20.1.134 | Columnf10GMUXCH2DDTxPWRLocal | read-only | current | Local FRM220-TM-10GMUX card CH2 D/D information: Tx power |
| 1.3.6.1.4.1.4756.20.700.20.1.135 | Columnf10GMUXCH2DDRxPWRLocal | read-only | current | Local FRM220-TM-10GMUX card CH2 D/D information: Rx power |
| 1.3.6.1.4.1.4756.20.700.20.1.136 | Columnf10GMUXCH2DDTempLocal | read-only | current | Local FRM220-TM-10GMUX card CH2 D/D information: Temperature in degree C |
| 1.3.6.1.4.1.4756.20.700.20.1.137 | Columnf10GMUXCH2SupplyVolLocal | read-only | current | Local FRM220-TM-10GMUX card CH2 D/D information: SupplyVol |
| 1.3.6.1.4.1.4756.20.700.20.1.138 | Columnf10GMUXCH2TxLaserBiasLocal | read-only | current | Local FRM220-TM-10GMUX card CH2 D/D information: Tx LaserBias |
| 1.3.6.1.4.1.4756.20.700.20.1.139 | Columnf10GMUXCH3DDVendorLocal | read-only | current | Local FRM220-TM-10GMUX card CH3 D/D information: Vendor name |
| 1.3.6.1.4.1.4756.20.700.20.1.140 | Columnf10GMUXCH3DDPartNoLocal | read-only | current | Local FRM220-TM-10GMUX card CH3 D/D information: Vendor part number |
| 1.3.6.1.4.1.4756.20.700.20.1.141 | Columnf10GMUXCH3DDVendorSNLocal | read-only | current | Local FRM220-TM-10GMUX card CH3 D/D information: Vendor SN |
| 1.3.6.1.4.1.4756.20.700.20.1.142 | Columnf10GMUXCH3DDFiberTypeLocal | read-only | current | Local FRM220-TM-10GMUX card CH3 D/D information: Fiber Type |
| 1.3.6.1.4.1.4756.20.700.20.1.143 | Columnf10GMUXCH3DDWaveLenLocal | read-only | current | Local FRM220-TM-10GMUX card CH3 D/D information: Wave length |
| 1.3.6.1.4.1.4756.20.700.20.1.144 | Columnf10GMUXCH3DDWaveLen2Local | read-only | current | Local FRM220-TM-10GMUX card CH3 D/D information: Wave length 2 |
| 1.3.6.1.4.1.4756.20.700.20.1.145 | Columnf10GMUXCH3DDLinkLenLocal | read-only | current | Local FRM220-TM-10GMUX card CH3 D/D information: Link length |
| 1.3.6.1.4.1.4756.20.700.20.1.146 | Columnf10GMUXCH3DDLenUnitLocal | read-only | current | Local FRM220-10GMUX card CH3 D/D information: Length Unit |
| 1.3.6.1.4.1.4756.20.700.20.1.147 | Columnf10GMUXCH3DDRxSensLocal | read-only | current | Local FRM220-TM-10GMUX card CH3 D/D information: Rx Sensitivity |
| 1.3.6.1.4.1.4756.20.700.20.1.148 | Columnf10GMUXCH3DDTxPWRLocal | read-only | current | Local FRM220-TM-10GMUX card CH3 D/D information: Tx power |
| 1.3.6.1.4.1.4756.20.700.20.1.149 | Columnf10GMUXCH3DDRxPWRLocal | read-only | current | Local FRM220-TM-10GMUX card CH3 D/D information: Rx power |
| 1.3.6.1.4.1.4756.20.700.20.1.150 | Columnf10GMUXCH3DDTempLocal | read-only | current | Local FRM220-TM-10GMUX card CH3 D/D information: Temperature in degree C |
| 1.3.6.1.4.1.4756.20.700.20.1.151 | Columnf10GMUXCH3SupplyVolLocal | read-only | current | Local FRM220-TM-10GMUX card CH3 D/D information: SupplyVol |
| 1.3.6.1.4.1.4756.20.700.20.1.152 | Columnf10GMUXCH3TxLaserBiasLocal | read-only | current | Local FRM220-TM-10GMUX card CH3 D/D information: Tx LaserBias |
| 1.3.6.1.4.1.4756.20.700.20.1.153 | Columnf10GMUXCH4DDVendorLocal | read-only | current | Local FRM220-TM-10GMUX card CH4 D/D information: Vendor name |
| 1.3.6.1.4.1.4756.20.700.20.1.154 | Columnf10GMUXCH4DDPartNoLocal | read-only | current | Local FRM220-TM-10GMUX card CH4 D/D information: Vendor part number |
| 1.3.6.1.4.1.4756.20.700.20.1.155 | Columnf10GMUXCH4DDVendorSNLocal | read-only | current | Local FRM220-TM-10GMUX card CH4 D/D information: Vendor SN |
| 1.3.6.1.4.1.4756.20.700.20.1.156 | Columnf10GMUXCH4DDFiberTypeLocal | read-only | current | Local FRM220-TM-10GMUX card CH4 D/D information: Fiber Type |
| 1.3.6.1.4.1.4756.20.700.20.1.157 | Columnf10GMUXCH4DDWaveLenLocal | read-only | current | Local FRM220-TM-10GMUX card CH4 D/D information: Wave length |
| 1.3.6.1.4.1.4756.20.700.20.1.158 | Columnf10GMUXCH4DDWaveLen2Local | read-only | current | Local FRM220-TM-10GMUX card CH4 D/D information: Wave length 2 |
| 1.3.6.1.4.1.4756.20.700.20.1.159 | Columnf10GMUXCH4DDLinkLenLocal | read-only | current | Local FRM220-TM-10GMUX card CH4 D/D information: Link length |
| 1.3.6.1.4.1.4756.20.700.20.1.160 | Columnf10GMUXCH4DDRxSensLocal | read-only | current | Local FRM220-TM-10GMUX card CH4 D/D information: Rx Sensitivity |
| 1.3.6.1.4.1.4756.20.700.20.1.161 | Columnf10GMUXCH4DDLenUnitLocal | read-only | current | Local FRM220-10GMUX card CH4 D/D information: Length Unit |
| 1.3.6.1.4.1.4756.20.700.20.1.162 | Columnf10GMUXCH4DDTxPWRLocal | read-only | current | Local FRM220-TM-10GMUX card CH4 D/D information: Tx power |
| 1.3.6.1.4.1.4756.20.700.20.1.163 | Columnf10GMUXCH4DDRxPWRLocal | read-only | current | Local FRM220-TM-10GMUX card CH4 D/D information: Rx power |
| 1.3.6.1.4.1.4756.20.700.20.1.164 | Columnf10GMUXCH4DDTempLocal | read-only | current | Local FRM220-TM-10GMUX card CH4 D/D information: Temperature in degree C |
| 1.3.6.1.4.1.4756.20.700.20.1.165 | Columnf10GMUXCH4SupplyVolLocal | read-only | current | Local FRM220-TM-10GMUX card CH4 D/D information: SupplyVol |
| 1.3.6.1.4.1.4756.20.700.20.1.166 | Columnf10GMUXCH4TxLaserBiasLocal | read-only | current | Local FRM220-TM-10GMUX card CH4 D/D information: Tx LaserBias |
| 1.3.6.1.4.1.4756.20.700.20.1.167 | Columnf10GMUXCH5DDVendorLocal | read-only | current | Local FRM220-TM-10GMUX card CH5 D/D information: Vendor name |
| 1.3.6.1.4.1.4756.20.700.20.1.168 | Columnf10GMUXCH5DDPartNoLocal | read-only | current | Local FRM220-TM-10GMUX card CH5 D/D information: Vendor part number |
| 1.3.6.1.4.1.4756.20.700.20.1.169 | Columnf10GMUXCH5DDVendorSNLocal | read-only | current | Local FRM220-TM-10GMUX card CH5 D/D information: Vendor SN |
| 1.3.6.1.4.1.4756.20.700.20.1.170 | Columnf10GMUXCH5DDFiberTypeLocal | read-only | current | Local FRM220-TM-10GMUX card CH5 D/D information: Fiber Type |
| 1.3.6.1.4.1.4756.20.700.20.1.171 | Columnf10GMUXCH5DDWaveLenLocal | read-only | current | Local FRM220-TM-10GMUX card CH5 D/D information: Wave length |
| 1.3.6.1.4.1.4756.20.700.20.1.172 | Columnf10GMUXCH5DDWaveLen2Local | read-only | current | Local FRM220-TM-10GMUX card CH5 D/D information: Wave length 2 |
| 1.3.6.1.4.1.4756.20.700.20.1.173 | Columnf10GMUXCH5DDLinkLenLocal | read-only | current | Local FRM220-TM-10GMUX card CH5 D/D information: Link length |
| 1.3.6.1.4.1.4756.20.700.20.1.174 | Columnf10GMUXCH5DDLenUnitLocal | read-only | current | Local FRM220-10GMUX card CH5 D/D information: Length Unit |
| 1.3.6.1.4.1.4756.20.700.20.1.175 | Columnf10GMUXCH5DDRxSensLocal | read-only | current | Local FRM220-TM-10GMUX card CH5 D/D information: Rx Sensitivity |
| 1.3.6.1.4.1.4756.20.700.20.1.176 | Columnf10GMUXCH5DDTxPWRLocal | read-only | current | Local FRM220-TM-10GMUX card CH5 D/D information: Tx power |
| 1.3.6.1.4.1.4756.20.700.20.1.177 | Columnf10GMUXCH5DDRxPWRLocal | read-only | current | Local FRM220-TM-10GMUX card CH5 D/D information: Rx power |
| 1.3.6.1.4.1.4756.20.700.20.1.178 | Columnf10GMUXCH5DDTempLocal | read-only | current | Local FRM220-TM-10GMUX card CH5 D/D information: Temperature in degree C |
| 1.3.6.1.4.1.4756.20.700.20.1.179 | Columnf10GMUXCH5SupplyVolLocal | read-only | current | Local FRM220-TM-10GMUX card CH5 D/D information: SupplyVol |
| 1.3.6.1.4.1.4756.20.700.20.1.180 | Columnf10GMUXCH5TxLaserBiasLocal | read-only | current | Local FRM220-TM-10GMUX card CH5 D/D information: Tx LaserBias |
| 1.3.6.1.4.1.4756.20.700.20.1.181 | Columnf10GMUXCH6DDVendorLocal | read-only | current | Local FRM220-TM-10GMUX card CH6 D/D information: Vendor name |
| 1.3.6.1.4.1.4756.20.700.20.1.182 | Columnf10GMUXCH6DDPartNoLocal | read-only | current | Local FRM220-TM-10GMUX card CH6 D/D information: Vendor part number |
| 1.3.6.1.4.1.4756.20.700.20.1.183 | Columnf10GMUXCH6DDVendorSNLocal | read-only | current | Local FRM220-TM-10GMUX card CH6 D/D information: Vendor SN |
| 1.3.6.1.4.1.4756.20.700.20.1.184 | Columnf10GMUXCH6DDFiberTypeLocal | read-only | current | Local FRM220-TM-10GMUX card CH6 D/D information: Fiber Type |
| 1.3.6.1.4.1.4756.20.700.20.1.185 | Columnf10GMUXCH6DDWaveLenLocal | read-only | current | Local FRM220-TM-10GMUX card CH6 D/D information: Wave length |
| 1.3.6.1.4.1.4756.20.700.20.1.186 | Columnf10GMUXCH6DDWaveLen2Local | read-only | current | Local FRM220-TM-10GMUX card CH6 D/D information: Wave length 2 |
| 1.3.6.1.4.1.4756.20.700.20.1.187 | Columnf10GMUXCH6DDLinkLenLocal | read-only | current | Local FRM220-TM-10GMUX card CH6 D/D information: Link length |
| 1.3.6.1.4.1.4756.20.700.20.1.188 | Columnf10GMUXCH6DDLenUnitLocal | read-only | current | Local FRM220-10GMUX card CH6 D/D information: Length Unit |
| 1.3.6.1.4.1.4756.20.700.20.1.189 | Columnf10GMUXCH6DDRxSensLocal | read-only | current | Local FRM220-TM-10GMUX card CH6 D/D information: Rx Sensitivity |
| 1.3.6.1.4.1.4756.20.700.20.1.190 | Columnf10GMUXCH6DDTxPWRLocal | read-only | current | Local FRM220-TM-10GMUX card CH6 D/D information: Tx power |
| 1.3.6.1.4.1.4756.20.700.20.1.191 | Columnf10GMUXCH6DDRxPWRLocal | read-only | current | Local FRM220-TM-10GMUX card CH6 D/D information: Rx power |
| 1.3.6.1.4.1.4756.20.700.20.1.192 | Columnf10GMUXCH6DDTempLocal | read-only | current | Local FRM220-TM-10GMUX card CH6 D/D information: Temperature in degree C |
| 1.3.6.1.4.1.4756.20.700.20.1.193 | Columnf10GMUXCH6SupplyVolLocal | read-only | current | Local FRM220-TM-10GMUX card CH6 D/D information: SupplyVol |
| 1.3.6.1.4.1.4756.20.700.20.1.194 | Columnf10GMUXCH6TxLaserBiasLocal | read-only | current | Local FRM220-TM-10GMUX card CH6 D/D information: Tx LaserBias |
| 1.3.6.1.4.1.4756.20.700.20.1.195 | Columnf10GMUXCH7DDVendorLocal | read-only | current | Local FRM220-TM-10GMUX card CH7 D/D information: Vendor name |
| 1.3.6.1.4.1.4756.20.700.20.1.196 | Columnf10GMUXCH7DDPartNoLocal | read-only | current | Local FRM220-TM-10GMUX card CH7 D/D information: Vendor part number |
| 1.3.6.1.4.1.4756.20.700.20.1.197 | Columnf10GMUXCH7DDVendorSNLocal | read-only | current | Local FRM220-TM-10GMUX card CH7 D/D information: Vendor SN |
| 1.3.6.1.4.1.4756.20.700.20.1.198 | Columnf10GMUXCH7DDFiberTypeLocal | read-only | current | Local FRM220-TM-10GMUX card CH7 D/D information: Fiber Type |
| 1.3.6.1.4.1.4756.20.700.20.1.199 | Columnf10GMUXCH7DDWaveLenLocal | read-only | current | Local FRM220-TM-10GMUX card CH7 D/D information: Wave length |
| 1.3.6.1.4.1.4756.20.700.20.1.200 | Columnf10GMUXCH7DDWaveLen2Local | read-only | current | Local FRM220-TM-10GMUX card CH7 D/D information: Wave length 2 |
| 1.3.6.1.4.1.4756.20.700.20.1.201 | Columnf10GMUXCH7DDLinkLenLocal | read-only | current | Local FRM220-TM-10GMUX card CH7 D/D information: Link length |
| 1.3.6.1.4.1.4756.20.700.20.1.202 | Columnf10GMUXCH7DDLenUnitLocal | read-only | current | Local FRM220-10GMUX card CH7 D/D information: Length Unit |
| 1.3.6.1.4.1.4756.20.700.20.1.203 | Columnf10GMUXCH7DDRxSensLocal | read-only | current | Local FRM220-TM-10GMUX card CH7 D/D information: Rx Sensitivity |
| 1.3.6.1.4.1.4756.20.700.20.1.204 | Columnf10GMUXCH7DDTxPWRLocal | read-only | current | Local FRM220-TM-10GMUX card CH7 D/D information: Tx power |
| 1.3.6.1.4.1.4756.20.700.20.1.205 | Columnf10GMUXCH7DDRxPWRLocal | read-only | current | Local FRM220-TM-10GMUX card CH7 D/D information: Rx power |
| 1.3.6.1.4.1.4756.20.700.20.1.206 | Columnf10GMUXCH7DDTempLocal | read-only | current | Local FRM220-TM-10GMUX card CH7 D/D information: Temperature in degree C |
| 1.3.6.1.4.1.4756.20.700.20.1.207 | Columnf10GMUXCH7SupplyVolLocal | read-only | current | Local FRM220-TM-10GMUX card CH7 D/D information: SupplyVol |
| 1.3.6.1.4.1.4756.20.700.20.1.208 | Columnf10GMUXCH7TxLaserBiasLocal | read-only | current | Local FRM220-TM-10GMUX card CH7 D/D information: Tx LaserBias |
| 1.3.6.1.4.1.4756.20.700.20.1.209 | Columnf10GMUXDeviceActiveLocal | read-write | current | Local FRM220-TM-10GMUX card active: 0:Inactive 1:Active |
| 1.3.6.1.4.1.4756.20.700.20.1.210 | Columnf10GMUXClrCVCntsLocal | read-write | current | Clear local device card CV IN/OUT counters: 0:No action 1:Action |
| 1.3.6.1.4.1.4756.20.700.20.1.211 | Columnf10GMUXTunableLinechORfreqLocal | read-write | current | Local FRM220-TM-10GMUX card Tunable Line chORfreq Mode. 0: Channel 1: Frequency |
| 1.3.6.1.4.1.4756.20.700.20.1.212 | Columnf10GMUXTunableLineChannelLocal | read-write | current | Local FRM220-TM-10GMUX card Tunable Line Channel setting. |
| 1.3.6.1.4.1.4756.20.700.20.1.213 | Columnf10GMUXTunableLineFrequencyLocal | read-write | current | Local FRM220-TM-10GMUX card Tunable Line Frequency setting. |
| 1.3.6.1.4.1.4756.20.700.20.1.214 | Columnf10GMUXPowerLedLocal | read-only | current | Local FRM220-TM-10GMUX card Powe Led. 0:ON (Power ON) 1:Flash (Standby; 1s ON/1s OFF) |
| 1.3.6.1.4.1.4756.20.700.20.1.215 | Columnf10GMUXSystemLedLocal | read-only | current | Local FRM220-TM-10GMUX card Syetem Led. 0:OFF 1:Link up 2:ON |
| 1.3.6.1.4.1.4756.20.700.20.1.216 | Columnf10GMUXAlarmLedLocal | read-only | current | Local FRM220-TM-10GMUX card Alarm Led. 0:OFF 1:ON |
| 1.3.6.1.4.1.4756.20.700.20.1.217 | Columnf10GMUXLFPTLedLocal | read-only | current | Local FRM220-TM-10GMUX card LFPT Led. 0:OFF 1:ON |
| 1.3.6.1.4.1.4756.20.700.20.1.218 | Columnf10GMUXLineLedLocal | read-only | current | Local FRM220-TM-10GMUX card Line Led. 0:OFF(Link Down) 1:link up (On: 0.5s, Off: 0.5s) 2:LB (On: 1s, Off: 1s) 3:ON (0.5s ON/0.5s OFF) |
| 1.3.6.1.4.1.4756.20.700.20.1.219 | Columnf10GMUXCH1LedLocal | read-only | current | Local FRM220-TM-10GMUX card CH1 Led. 0:OFF(Link Down) 1:link up (On: 0.5s, Off: 0.5s) 2:LB (On: 1s, Off: 1s) 3:ON (0.5s ON/0.5s OFF) |
| 1.3.6.1.4.1.4756.20.700.20.1.220 | Columnf10GMUXCH2LedLocal | read-only | current | Local FRM220-TM-10GMUX card CH2 Led. 0:OFF(Link Down) 1:link up (On: 0.5s, Off: 0.5s) 2:LB (On: 1s, Off: 1s) 3:ON (0.5s ON/0.5s OFF) |
| 1.3.6.1.4.1.4756.20.700.20.1.221 | Columnf10GMUXCH3LedLocal | read-only | current | Local FRM220-TM-10GMUX card CH3 Led. 0:OFF(Link Down) 1:link up (On: 0.5s, Off: 0.5s) 2:LB (On: 1s, Off: 1s) 3:ON (0.5s ON/0.5s OFF) |
| 1.3.6.1.4.1.4756.20.700.20.1.222 | Columnf10GMUXCH4LedLocal | read-only | current | Local FRM220-TM-10GMUX card CH4 Led. 0:OFF(Link Down) 1:link up (On: 0.5s, Off: 0.5s) 2:LB (On: 1s, Off: 1s) 3:ON (0.5s ON/0.5s OFF) |
| 1.3.6.1.4.1.4756.20.700.20.1.223 | Columnf10GMUXCH5LedLocal | read-only | current | Local FRM220-TM-10GMUX card CH5 Led. 0:OFF(Link Down) 1:link up (On: 0.5s, Off: 0.5s) 2:LB (On: 1s, Off: 1s) 3:ON (0.5s ON/0.5s OFF) |
| 1.3.6.1.4.1.4756.20.700.20.1.224 | Columnf10GMUXCH6LedLocal | read-only | current | Local FRM220-TM-10GMUX card CH6 Led. 0:OFF(Link Down) 1:link up (On: 0.5s, Off: 0.5s) 2:LB (On: 1s, Off: 1s) 3:ON (0.5s ON/0.5s OFF) |
| 1.3.6.1.4.1.4756.20.700.20.1.225 | Columnf10GMUXCH7LedLocal | read-only | current | Local FRM220-TM-10GMUX card CH7 Led. 0:OFF(Link Down) 1:link up (On: 0.5s, Off: 0.5s) 2:LB (On: 1s, Off: 1s) 3:ON (0.5s ON/0.5s OFF) |
| 1.3.6.1.4.1.4756.20.701 | Nodef10GMUXRemoteCards | |||
| 1.3.6.1.4.1.4756.20.701.20 | Tablef10GMUXRemoteTable | not-accessible | current | A list of local FRM220-TM-10GMUX Line Card entries. The number of entries is f10GMUX-No-L. |
| 1.3.6.1.4.1.4756.20.701.20.1 | Rowf10GMUXRemoteEntry | not-accessible | current | An entry containing management information applicable to a particular local FRM220-TM-10GMUX Line Card. |
| 1.3.6.1.4.1.4756.20.701.20.1.1 | Columnf10GMUXChassisIndexRemote | read-only | current | A unique value for each local card. It is the chassis location number. |
| 1.3.6.1.4.1.4756.20.701.20.1.2 | Columnf10GMUXSlotIndexRemote | read-only | current | A unique value for each local card. It is the slot location number. |
| 1.3.6.1.4.1.4756.20.701.20.1.3 | Columnf10GMUXCardHWVerRemote | read-only | current | Local FRM220-TM-10GMUX Line Card hardware version x.xxx |
| 1.3.6.1.4.1.4756.20.701.20.1.4 | Columnf10GMUXCardFWVerRemote | read-only | current | Local FRM220-TM-10GMUX Line Card firmware version x.xxx |
| 1.3.6.1.4.1.4756.20.701.20.1.5 | Columnf10GMUXCardCPLDVerRemote | read-only | current | Local FRM220-TM-10GMUX Line Card CPLD version x.xxx |
| 1.3.6.1.4.1.4756.20.701.20.1.6 | Columnf10GMUXCardFPGAVerRemote | read-only | current | Local FRM220-TM-10GMUX Line Card FPGA version x.xxx |
| 1.3.6.1.4.1.4756.20.701.20.1.7 | Columnf10GMUXPortResetRemote | read-write | current | Local FRM220-TM-10GMUX card to reset mode: 0:Off 1:Action |
| 1.3.6.1.4.1.4756.20.701.20.1.8 | Columnf10GMUXSetToDefaultRemote | read-write | current | Local FRM220-TM-10GMUX card set to default : 0:Off 1:Action |
| 1.3.6.1.4.1.4756.20.701.20.1.9 | Columnf10GMUXLineExistRemote | read-only | current | Local FRM220-TM-10GMUX card Line Exist status: 0:Empty 1:Exist |
| 1.3.6.1.4.1.4756.20.701.20.1.10 | Columnf10GMUXCH1ExistRemote | read-only | current | Local FRM220-TM-10GMUX card CH1 Exist status: 0:Empty 1:Exist |
| 1.3.6.1.4.1.4756.20.701.20.1.11 | Columnf10GMUXCH2ExistRemote | read-only | current | Local FRM220-TM-10GMUX card CH2 Exist status: 0:Empty 1:Exist |
| 1.3.6.1.4.1.4756.20.701.20.1.12 | Columnf10GMUXCH3ExistRemote | read-only | current | Local FRM220-TM-10GMUX card CH3 Exist status: 0:Empty 1:Exist |
| 1.3.6.1.4.1.4756.20.701.20.1.13 | Columnf10GMUXCH4ExistRemote | read-only | current | Local FRM220-TM-10GMUX card CH4 Exist status: 0:Empty 1:Exist |
| 1.3.6.1.4.1.4756.20.701.20.1.14 | Columnf10GMUXCH5ExistRemote | read-only | current | Local FRM220-TM-10GMUX card CH5 Exist status: 0:Empty 1:Exist |
| 1.3.6.1.4.1.4756.20.701.20.1.15 | Columnf10GMUXCH6ExistRemote | read-only | current | Local FRM220-TM-10GMUX card CH6 Exist status: 0:Empty 1:Exist |
| 1.3.6.1.4.1.4756.20.701.20.1.16 | Columnf10GMUXCH7ExistRemote | read-only | current | Local FRM220-TM-10GMUX card CH7 Exist status: 0:Empty 1:Exist |
| 1.3.6.1.4.1.4756.20.701.20.1.17 | Columnf10GMUXLineLinkRemote | read-only | current | Local FRM220-TM-10GMUX card Line Link status: 0:Down 1:up |
| 1.3.6.1.4.1.4756.20.701.20.1.18 | Columnf10GMUXCH1LinkRemote | read-only | current | Local FRM220-TM-10GMUX card CH1 Link status: 0:Down 1:up |
| 1.3.6.1.4.1.4756.20.701.20.1.19 | Columnf10GMUXCH2LinkRemote | read-only | current | Local FRM220-TM-10GMUX card CH2 Link status: 0:Down 1:up |
| 1.3.6.1.4.1.4756.20.701.20.1.20 | Columnf10GMUXCH3LinkRemote | read-only | current | Local FRM220-TM-10GMUX card CH3 Link status: 0:Down 1:up |
| 1.3.6.1.4.1.4756.20.701.20.1.21 | Columnf10GMUXCH4LinkRemote | read-only | current | Local FRM220-TM-10GMUX card CH4 Link status: 0:Down 1:up |
| 1.3.6.1.4.1.4756.20.701.20.1.22 | Columnf10GMUXCH5LinkRemote | read-only | current | Local FRM220-TM-10GMUX card CH5 Link status: 0:Down 1:up |
| 1.3.6.1.4.1.4756.20.701.20.1.23 | Columnf10GMUXCH6LinkRemote | read-only | current | Local FRM220-TM-10GMUX card CH6 Link status: 0:Down 1:up |
| 1.3.6.1.4.1.4756.20.701.20.1.24 | Columnf10GMUXCH7LinkRemote | read-only | current | Local FRM220-TM-10GMUX card CH7 Link status: 0:Down 1:up |
| 1.3.6.1.4.1.4756.20.701.20.1.25 | Columnf10GMUXLineSyncRemote | read-only | current | Local FRM220-TM-10GMUX card Line Sync status: 0:No 1:Yes |
| 1.3.6.1.4.1.4756.20.701.20.1.26 | Columnf10GMUXCH1SyncRemote | read-only | current | Local FRM220-TM-10GMUX card CH1 Sync status: 0:No 1:Yes |
| 1.3.6.1.4.1.4756.20.701.20.1.27 | Columnf10GMUXCH2SyncRemote | read-only | current | Local FRM220-TM-10GMUX card CH2 Sync status: 0:No 1:Yes |
| 1.3.6.1.4.1.4756.20.701.20.1.28 | Columnf10GMUXCH3SyncRemote | read-only | current | Local FRM220-TM-10GMUX card CH3 Sync status: 0:No 1:Yes |
| 1.3.6.1.4.1.4756.20.701.20.1.29 | Columnf10GMUXCH4SyncRemote | read-only | current | Local FRM220-TM-10GMUX card CH4 Sync status: 0:Not Locked 1:Yes |
| 1.3.6.1.4.1.4756.20.701.20.1.30 | Columnf10GMUXCH5SyncRemote | read-only | current | Local FRM220-TM-10GMUX card CH5 Sync status: 0:No 1:Yes |
| 1.3.6.1.4.1.4756.20.701.20.1.31 | Columnf10GMUXCH6SyncRemote | read-only | current | Local FRM220-TM-10GMUX card CH6 Sync status: 0:No 1:Yes |
| 1.3.6.1.4.1.4756.20.701.20.1.32 | Columnf10GMUXCH7SyncRemote | read-only | current | Local FRM220-TM-10GMUX card CH7 Sync status: 0:no 1:yes |
| 1.3.6.1.4.1.4756.20.701.20.1.33 | Columnf10GMUXLineTxFaultRemote | read-only | current | Local FRM220-TM-10GMUX card Line Tx Fault status: 0:Normal 1:Failure |
| 1.3.6.1.4.1.4756.20.701.20.1.34 | Columnf10GMUXCH1TxFaultRemote | read-only | current | Local FRM220-TM-10GMUX card CH1 Tx Fault status: 0:Normal 1:Failure |
| 1.3.6.1.4.1.4756.20.701.20.1.35 | Columnf10GMUXCH2TxFaultRemote | read-only | current | Local FRM220-TM-10GMUX card CH2 Tx Fault status: 0:Normal 1:Failure |
| 1.3.6.1.4.1.4756.20.701.20.1.36 | Columnf10GMUXCH3TxFaultRemote | read-only | current | Local FRM220-TM-10GMUX card CH3 Tx Fault status: 0:Normal 1:Failure |
| 1.3.6.1.4.1.4756.20.701.20.1.37 | Columnf10GMUXCH4TxFaultRemote | read-only | current | Local FRM220-TM-10GMUX card CH4 Tx Fault status: 0:Normal 1:Failure |
| 1.3.6.1.4.1.4756.20.701.20.1.38 | Columnf10GMUXCH5TxFaultRemote | read-only | current | Local FRM220-TM-10GMUX card CH5 Tx Fault status: 0:Normal 1:Failure |
| 1.3.6.1.4.1.4756.20.701.20.1.39 | Columnf10GMUXCH6TxFaultRemote | read-only | current | Local FRM220-TM-10GMUX card CH6 Tx Fault status: 0:Normal 1:Failure |
| 1.3.6.1.4.1.4756.20.701.20.1.40 | Columnf10GMUXCH7TxFaultRemote | read-only | current | Local FRM220-TM-10GMUX card CH7 Tx Fault status: 0:Normal 1:Failure |
| 1.3.6.1.4.1.4756.20.701.20.1.41 | Columnf10GMUXLineDDRemote | read-only | current | Local FRM220-TM-10GMUX card Line DD status: 0:no 1:yes |
| 1.3.6.1.4.1.4756.20.701.20.1.42 | Columnf10GMUXCH1DDRemote | read-only | current | Local FRM220-TM-10GMUX card CH1 DD status: 0:no 1:yes |
| 1.3.6.1.4.1.4756.20.701.20.1.43 | Columnf10GMUXCH2DDRemote | read-only | current | Local FRM220-TM-10GMUX card CH2 DD status: 0:no 1:yes |
| 1.3.6.1.4.1.4756.20.701.20.1.44 | Columnf10GMUXCH3DDRemote | read-only | current | Local FRM220-TM-10GMUX card CH3 DD status: 0:no 1:yes |
| 1.3.6.1.4.1.4756.20.701.20.1.45 | Columnf10GMUXCH4DDRemote | read-only | current | Local FRM220-TM-10GMUX card CH4 DD status: 0:no 1:yes |
| 1.3.6.1.4.1.4756.20.701.20.1.46 | Columnf10GMUXCH5DDRemote | read-only | current | Local FRM220-TM-10GMUX card CH5 DD status: 0:no 1:yes |
| 1.3.6.1.4.1.4756.20.701.20.1.47 | Columnf10GMUXCH6DDRemote | read-only | current | Local FRM220-TM-10GMUX card CH6 DD status: 0:no 1:yes |
| 1.3.6.1.4.1.4756.20.701.20.1.48 | Columnf10GMUXCH7DDRemote | read-only | current | Local FRM220-TM-10GMUX card CH7 DD status: 0:no 1:yes |
| 1.3.6.1.4.1.4756.20.701.20.1.49 | Columnf10GMUXLineCounterRemote | read-only | current | FRM220-10GMUX cards Line Counter. |
| 1.3.6.1.4.1.4756.20.701.20.1.50 | Columnf10GMUXCH1CounterRemote | read-only | current | FRM220-10GMUX cards CH1 Counter. |
| 1.3.6.1.4.1.4756.20.701.20.1.51 | Columnf10GMUXCH2CounterRemote | read-only | current | FRM220-10GMUX cards CH2 Counter. |
| 1.3.6.1.4.1.4756.20.701.20.1.52 | Columnf10GMUXCH3CounterRemote | read-only | current | FRM220-10GMUX cards CH3 Counter. |
| 1.3.6.1.4.1.4756.20.701.20.1.53 | Columnf10GMUXCH4CounterRemote | read-only | current | FRM220-10GMUX cards CH4 Counter. |
| 1.3.6.1.4.1.4756.20.701.20.1.54 | Columnf10GMUXCH5CounterRemote | read-only | current | FRM220-10GMUX cards CH5 Counter. |
| 1.3.6.1.4.1.4756.20.701.20.1.55 | Columnf10GMUXCH6CounterRemote | read-only | current | FRM220-10GMUX cards CH6 Counter. |
| 1.3.6.1.4.1.4756.20.701.20.1.56 | Columnf10GMUXCH7CounterRemote | read-only | current | FRM220-10GMUX cards CH7 Counter. |
| 1.3.6.1.4.1.4756.20.701.20.1.57 | Columnf10GMUXLinePortActiveRemote | read-only | current | FRM220-10GMUX cards Line Port Active: 0:disable 1:enable |
| 1.3.6.1.4.1.4756.20.701.20.1.58 | Columnf10GMUXCH1PortActiveRemote | read-write | current | FRM220-10GMUX cards CH1 Port Active: 0:disable 1:enable |
| 1.3.6.1.4.1.4756.20.701.20.1.59 | Columnf10GMUXCH2PortActiveRemote | read-write | current | FRM220-10GMUX cards CH2 Port Active: 0:disable 1:enable |
| 1.3.6.1.4.1.4756.20.701.20.1.60 | Columnf10GMUXCH3PortActiveRemote | read-write | current | FRM220-10GMUX cards CH3 Port Active: 0:disable 1:enable |
| 1.3.6.1.4.1.4756.20.701.20.1.61 | Columnf10GMUXCH4PortActiveRemote | read-write | current | FRM220-10GMUX cards CH4 Port Active: 0:disable 1:enable |
| 1.3.6.1.4.1.4756.20.701.20.1.62 | Columnf10GMUXCH5PortActiveRemote | read-write | current | FRM220-10GMUX cards CH5 Port Active: 0:disable 1:enable |
| 1.3.6.1.4.1.4756.20.701.20.1.63 | Columnf10GMUXCH6PortActiveRemote | read-write | current | FRM220-10GMUX cards CH6 Port Active: 0:disable 1:enable |
| 1.3.6.1.4.1.4756.20.701.20.1.64 | Columnf10GMUXCH7PortActiveRemote | read-write | current | FRM220-10GMUX cards CH7 Port Active: 0:disable 1:enable |
| 1.3.6.1.4.1.4756.20.701.20.1.65 | Columnf10GMUXLineLFPRemote | read-write | current | Local FRM220-TM-10GMUX card Line Link Fault Pass Through: 0:Disable 1:Enable |
| 1.3.6.1.4.1.4756.20.701.20.1.66 | Columnf10GMUXCH1LFPRemote | read-write | current | Local FRM220-TM-10GMUX card CH1 Link Fault Pass Through: 0:Disable 1:Enable |
| 1.3.6.1.4.1.4756.20.701.20.1.67 | Columnf10GMUXCH2LFPRemote | read-write | current | Local FRM220-TM-10GMUX card CH2 Link Fault Pass Through: 0:Disable 1:Enable |
| 1.3.6.1.4.1.4756.20.701.20.1.68 | Columnf10GMUXCH3LFPRemote | read-write | current | Local FRM220-TM-10GMUX card CH3 Link Fault Pass Through: 0:Disable 1:Enable |
| 1.3.6.1.4.1.4756.20.701.20.1.69 | Columnf10GMUXCH4LFPRemote | read-write | current | Local FRM220-TM-10GMUX card CH4 Link Fault Pass Through: 0:Disable 1:Enable |
| 1.3.6.1.4.1.4756.20.701.20.1.70 | Columnf10GMUXCH5LFPRemote | read-write | current | Local FRM220-TM-10GMUX card CH5 Link Fault Pass Through: 0:Disable 1:Enable |
| 1.3.6.1.4.1.4756.20.701.20.1.71 | Columnf10GMUXCH6LFPRemote | read-write | current | Local FRM220-TM-10GMUX card CH6 Link Fault Pass Through: 0:Disable 1:Enable |
| 1.3.6.1.4.1.4756.20.701.20.1.72 | Columnf10GMUXCH7LFPRemote | read-write | current | Local FRM220-TM-10GMUX card CH7 Link Fault Pass Through: 0:Disable 1:Enable |
| 1.3.6.1.4.1.4756.20.701.20.1.73 | Columnf10GMUXLineALSRemote | read-write | current | Local FRM220-TM-10GMUX card Line Auto Laser Showdown: 0:Disable 1:Enable |
| 1.3.6.1.4.1.4756.20.701.20.1.74 | Columnf10GMUXCH1ALSRemote | read-write | current | Local FRM220-TM-10GMUX card CH1 Auto Laser Showdown: 0:Disable 1:Enable |
| 1.3.6.1.4.1.4756.20.701.20.1.75 | Columnf10GMUXCH2ALSRemote | read-write | current | Local FRM220-TM-10GMUX card CH2 Auto Laser Showdown: 0:Disable 1:Enable |
| 1.3.6.1.4.1.4756.20.701.20.1.76 | Columnf10GMUXCH3ALSRemote | read-write | current | Local FRM220-TM-10GMUX card CH3 Auto Laser Showdown: 0:Disable 1:Enable |
| 1.3.6.1.4.1.4756.20.701.20.1.77 | Columnf10GMUXCH4ALSRemote | read-write | current | Local FRM220-TM-10GMUX card CH4 Auto Laser Showdown: 0:Disable 1:Enable |
| 1.3.6.1.4.1.4756.20.701.20.1.78 | Columnf10GMUXCH5ALSRemote | read-write | current | Local FRM220-TM-10GMUX card CH5 Auto Laser Showdown: 0:Disable 1:Enable |
| 1.3.6.1.4.1.4756.20.701.20.1.79 | Columnf10GMUXCH6ALSRemote | read-write | current | Local FRM220-TM-10GMUX card CH6 Auto Laser Showdown: 0:Disable 1:Enable |
| 1.3.6.1.4.1.4756.20.701.20.1.80 | Columnf10GMUXCH7ALSRemote | read-write | current | Local FRM220-TM-10GMUX card CH7 Auto Laser Showdown: 0:Disable 1:Enable |
| 1.3.6.1.4.1.4756.20.701.20.1.81 | Columnf10GMUXCH1LoopbackRemote | read-write | current | Local FRM220-TM-10GMUX card CH1 Loopback: 0:Disable 1:Enable |
| 1.3.6.1.4.1.4756.20.701.20.1.82 | Columnf10GMUXCH2LoopbackRemote | read-write | current | Local FRM220-TM-10GMUX card CH2 Loopback: 0:Disable 1:Enable |
| 1.3.6.1.4.1.4756.20.701.20.1.83 | Columnf10GMUXCH3LoopbackRemote | read-write | current | Local FRM220-TM-10GMUX card CH3 Loopback: 0:Disable 1:Enable |
| 1.3.6.1.4.1.4756.20.701.20.1.84 | Columnf10GMUXCH4LoopbackRemote | read-write | current | Local FRM220-TM-10GMUX card CH4 Loopback: 0:Disable 1:Enable |
| 1.3.6.1.4.1.4756.20.701.20.1.85 | Columnf10GMUXCH5LoopbackRemote | read-write | current | Local FRM220-TM-10GMUX card CH5 Loopback: 0:Disable 1:Enable |
| 1.3.6.1.4.1.4756.20.701.20.1.86 | Columnf10GMUXCH6LoopbackRemote | read-write | current | Local FRM220-TM-10GMUX card CH6 Loopback: 0:Disable 1:Enable |
| 1.3.6.1.4.1.4756.20.701.20.1.87 | Columnf10GMUXCH7LoopbackRemote | read-write | current | Local FRM220-TM-10GMUX card CH7 Loopback: 0:Disable 1:Enable |
| 1.3.6.1.4.1.4756.20.701.20.1.88 | Columnf10GMUXAlarmStatusRemote | read-only | current | Local FRM220-TM-10GMUX card Alarm status: 0:Normal 1:Abmormal |
| 1.3.6.1.4.1.4756.20.701.20.1.89 | Columnf10GMUXLineTriggerRemote | read-write | current | FRM220-10GMUX cards Line Trigger: 0:disable 1:enable |
| 1.3.6.1.4.1.4756.20.701.20.1.90 | Columnf10GMUXCH1TriggerRemote | read-write | current | FRM220-10GMUX cards CH1 Trigger: 0:disable 1:enable |
| 1.3.6.1.4.1.4756.20.701.20.1.91 | Columnf10GMUXCH2TriggerRemote | read-write | current | FRM220-10GMUX cards CH2 Trigger: 0:disable 1:enable |
| 1.3.6.1.4.1.4756.20.701.20.1.92 | Columnf10GMUXCH3TriggerRemote | read-write | current | FRM220-10GMUX cards CH3 Trigger: 0:disable 1:enable |
| 1.3.6.1.4.1.4756.20.701.20.1.93 | Columnf10GMUXCH4TriggerRemote | read-write | current | FRM220-10GMUX cards CH4 Trigger: 0:disable 1:enable |
| 1.3.6.1.4.1.4756.20.701.20.1.94 | Columnf10GMUXCH5TriggerRemote | read-write | current | FRM220-10GMUX cards CH5 Trigger: 0:disable 1:enable |
| 1.3.6.1.4.1.4756.20.701.20.1.95 | Columnf10GMUXCH6TriggerRemote | read-write | current | FRM220-10GMUX cards CH6 Trigger: 0:disable 1:enable |
| 1.3.6.1.4.1.4756.20.701.20.1.96 | Columnf10GMUXCH7TriggerRemote | read-write | current | FRM220-10GMUX cards CH7 Trigger: 0:disable 1:enable |
| 1.3.6.1.4.1.4756.20.701.20.1.97 | Columnf10GMUXLineDDVendorRemote | read-only | current | Local FRM220-TM-10GMUX card Line D/D information: Vendor name |
| 1.3.6.1.4.1.4756.20.701.20.1.98 | Columnf10GMUXLineDDPartNoRemote | read-only | current | Local FRM220-TM-10GMUX card Line D/D information: Vendor part number |
| 1.3.6.1.4.1.4756.20.701.20.1.99 | Columnf10GMUXLineDDVendorSNRemote | read-only | current | Local FRM220-TM-10GMUX card Line D/D information: Vendor SN |
| 1.3.6.1.4.1.4756.20.701.20.1.100 | Columnf10GMUXLineDDFiberTypeRemote | read-only | current | Local FRM220-TM-10GMUX card Line D/D information: Fiber Type |
| 1.3.6.1.4.1.4756.20.701.20.1.101 | Columnf10GMUXLineDDWaveLenRemote | read-only | current | Local FRM220-TM-10GMUX card Line D/D information: Wave length |
| 1.3.6.1.4.1.4756.20.701.20.1.102 | Columnf10GMUXLineDDWaveLen2Remote | read-only | current | Local FRM220-TM-10GMUX card Line D/D information: Wave length 2 |
| 1.3.6.1.4.1.4756.20.701.20.1.103 | Columnf10GMUXLineDDLinkLenRemote | read-only | current | Local FRM220-TM-10GMUX card Line D/D information: Link length |
| 1.3.6.1.4.1.4756.20.701.20.1.104 | Columnf10GMUXLineDDLenUnitRemote | read-only | current | Remote FRM220-10GMUX card Line D/D information: Length Unit |
| 1.3.6.1.4.1.4756.20.701.20.1.105 | Columnf10GMUXLineDDRxSensRemote | read-only | current | Local FRM220-TM-10GMUX card Line D/D information: Rx Sensitivity |
| 1.3.6.1.4.1.4756.20.701.20.1.106 | Columnf10GMUXLineDDTxPWRRemote | read-only | current | Local FRM220-TM-10GMUX card Line D/D information: Tx power |
| 1.3.6.1.4.1.4756.20.701.20.1.107 | Columnf10GMUXLineDDRxPWRRemote | read-only | current | Local FRM220-TM-10GMUX card Line D/D information: Rx power |
| 1.3.6.1.4.1.4756.20.701.20.1.108 | Columnf10GMUXLineDDTempRemote | read-only | current | Local FRM220-TM-10GMUX card Line D/D information: Temperature in degree C |
| 1.3.6.1.4.1.4756.20.701.20.1.109 | Columnf10GMUXLineSupplyVolRemote | read-only | current | Local FRM220-TM-10GMUX card Line D/D information: SupplyVol |
| 1.3.6.1.4.1.4756.20.701.20.1.110 | Columnf10GMUXLineTxLaserBiasRemote | read-only | current | Local FRM220-TM-10GMUX card Line D/D information: Tx LaserBias |
| 1.3.6.1.4.1.4756.20.701.20.1.111 | Columnf10GMUXCH1DDVendorRemote | read-only | current | Local FRM220-TM-10GMUX card CH1 D/D information: Vendor name |
| 1.3.6.1.4.1.4756.20.701.20.1.112 | Columnf10GMUXCH1DDPartNoRemote | read-only | current | Local FRM220-TM-10GMUX card CH1 D/D information: Vendor part number |
| 1.3.6.1.4.1.4756.20.701.20.1.113 | Columnf10GMUXCH1DDVendorSNRemote | read-only | current | Local FRM220-TM-10GMUX card CH1 D/D information: Vendor SN |
| 1.3.6.1.4.1.4756.20.701.20.1.114 | Columnf10GMUXCH1DDFiberTypeRemote | read-only | current | Local FRM220-TM-10GMUX card CH1 D/D information: Fiber Type |
| 1.3.6.1.4.1.4756.20.701.20.1.115 | Columnf10GMUXCH1DDWaveLenRemote | read-only | current | Local FRM220-TM-10GMUX card CH1 D/D information: Wave length |
| 1.3.6.1.4.1.4756.20.701.20.1.116 | Columnf10GMUXCH1DDWaveLen2Remote | read-only | current | Local FRM220-TM-10GMUX card CH1 D/D information: Wave length 2 |
| 1.3.6.1.4.1.4756.20.701.20.1.117 | Columnf10GMUXCH1DDLinkLenRemote | read-only | current | Local FRM220-TM-10GMUX card CH1 D/D information: Link length |
| 1.3.6.1.4.1.4756.20.701.20.1.118 | Columnf10GMUXCH1DDLenUnitRemote | read-only | current | Remote FRM220-10GMUX card CH1 D/D information: Length Unit |
| 1.3.6.1.4.1.4756.20.701.20.1.119 | Columnf10GMUXCH1DDRxSensRemote | read-only | current | Local FRM220-TM-10GMUX card CH1 D/D information: Rx Sensitivity |
| 1.3.6.1.4.1.4756.20.701.20.1.120 | Columnf10GMUXCH1DDTxPWRRemote | read-only | current | Local FRM220-TM-10GMUX card CH1 D/D information: Tx power |
| 1.3.6.1.4.1.4756.20.701.20.1.121 | Columnf10GMUXCH1DDRxPWRRemote | read-only | current | Local FRM220-TM-10GMUX card CH1 D/D information: Rx power |
| 1.3.6.1.4.1.4756.20.701.20.1.122 | Columnf10GMUXCH1DDTempRemote | read-only | current | Local FRM220-TM-10GMUX card CH1 D/D information: Temperature in degree C |
| 1.3.6.1.4.1.4756.20.701.20.1.123 | Columnf10GMUXCH1SupplyVolRemote | read-only | current | Local FRM220-TM-10GMUX card CH1 D/D information: SupplyVol |
| 1.3.6.1.4.1.4756.20.701.20.1.124 | Columnf10GMUXCH1TxLaserBiasRemote | read-only | current | Local FRM220-TM-10GMUX card CH1 D/D information: Tx LaserBias |
| 1.3.6.1.4.1.4756.20.701.20.1.125 | Columnf10GMUXCH2DDVendorRemote | read-only | current | Local FRM220-TM-10GMUX card CH2 D/D information: Vendor name |
| 1.3.6.1.4.1.4756.20.701.20.1.126 | Columnf10GMUXCH2DDPartNoRemote | read-only | current | Local FRM220-TM-10GMUX card CH2 D/D information: Vendor part number |
| 1.3.6.1.4.1.4756.20.701.20.1.127 | Columnf10GMUXCH2DDVendorSNRemote | read-only | current | Local FRM220-TM-10GMUX card CH2 D/D information: Vendor SN |
| 1.3.6.1.4.1.4756.20.701.20.1.128 | Columnf10GMUXCH2DDFiberTypeRemote | read-only | current | Local FRM220-TM-10GMUX card CH2 D/D information: Fiber Type |
| 1.3.6.1.4.1.4756.20.701.20.1.129 | Columnf10GMUXCH2DDWaveLenRemote | read-only | current | Local FRM220-TM-10GMUX card CH2 D/D information: Wave length |
| 1.3.6.1.4.1.4756.20.701.20.1.130 | Columnf10GMUXCH2DDWaveLen2Remote | read-only | current | Local FRM220-TM-10GMUX card CH2 D/D information: Wave length 2 |
| 1.3.6.1.4.1.4756.20.701.20.1.131 | Columnf10GMUXCH2DDLinkLenRemote | read-only | current | Local FRM220-TM-10GMUX card CH2 D/D information: Link length |
| 1.3.6.1.4.1.4756.20.701.20.1.132 | Columnf10GMUXCH2DDLenUnitRemote | read-only | current | Remote FRM220-10GMUX card CH2 D/D information: Length Unit |
| 1.3.6.1.4.1.4756.20.701.20.1.133 | Columnf10GMUXCH2DDRxSensRemote | read-only | current | Local FRM220-TM-10GMUX card CH2 D/D information: Rx Sensitivity |
| 1.3.6.1.4.1.4756.20.701.20.1.134 | Columnf10GMUXCH2DDTxPWRRemote | read-only | current | Local FRM220-TM-10GMUX card CH2 D/D information: Tx power |
| 1.3.6.1.4.1.4756.20.701.20.1.135 | Columnf10GMUXCH2DDRxPWRRemote | read-only | current | Local FRM220-TM-10GMUX card CH2 D/D information: Rx power |
| 1.3.6.1.4.1.4756.20.701.20.1.136 | Columnf10GMUXCH2DDTempRemote | read-only | current | Local FRM220-TM-10GMUX card CH2 D/D information: Temperature in degree C |
| 1.3.6.1.4.1.4756.20.701.20.1.137 | Columnf10GMUXCH2SupplyVolRemote | read-only | current | Local FRM220-TM-10GMUX card CH2 D/D information: SupplyVol |
| 1.3.6.1.4.1.4756.20.701.20.1.138 | Columnf10GMUXCH2TxLaserBiasRemote | read-only | current | Local FRM220-TM-10GMUX card CH2 D/D information: Tx LaserBias |
| 1.3.6.1.4.1.4756.20.701.20.1.139 | Columnf10GMUXCH3DDVendorRemote | read-only | current | Local FRM220-TM-10GMUX card CH3 D/D information: Vendor name |
| 1.3.6.1.4.1.4756.20.701.20.1.140 | Columnf10GMUXCH3DDPartNoRemote | read-only | current | Local FRM220-TM-10GMUX card CH3 D/D information: Vendor part number |
| 1.3.6.1.4.1.4756.20.701.20.1.141 | Columnf10GMUXCH3DDVendorSNRemote | read-only | current | Local FRM220-TM-10GMUX card CH3 D/D information: Vendor SN |
| 1.3.6.1.4.1.4756.20.701.20.1.142 | Columnf10GMUXCH3DDFiberTypeRemote | read-only | current | Local FRM220-TM-10GMUX card CH3 D/D information: Fiber Type |
| 1.3.6.1.4.1.4756.20.701.20.1.143 | Columnf10GMUXCH3DDWaveLenRemote | read-only | current | Local FRM220-TM-10GMUX card CH3 D/D information: Wave length |
| 1.3.6.1.4.1.4756.20.701.20.1.144 | Columnf10GMUXCH3DDWaveLen2Remote | read-only | current | Local FRM220-TM-10GMUX card CH3 D/D information: Wave length 2 |
| 1.3.6.1.4.1.4756.20.701.20.1.145 | Columnf10GMUXCH3DDLinkLenRemote | read-only | current | Local FRM220-TM-10GMUX card CH3 D/D information: Link length |
| 1.3.6.1.4.1.4756.20.701.20.1.146 | Columnf10GMUXCH3DDLenUnitRemote | read-only | current | Remote FRM220-10GMUX card CH3 D/D information: Length Unit |
| 1.3.6.1.4.1.4756.20.701.20.1.147 | Columnf10GMUXCH3DDRxSensRemote | read-only | current | Local FRM220-TM-10GMUX card CH3 D/D information: Rx Sensitivity |
| 1.3.6.1.4.1.4756.20.701.20.1.148 | Columnf10GMUXCH3DDTxPWRRemote | read-only | current | Local FRM220-TM-10GMUX card CH3 D/D information: Tx power |
| 1.3.6.1.4.1.4756.20.701.20.1.149 | Columnf10GMUXCH3DDRxPWRRemote | read-only | current | Local FRM220-TM-10GMUX card CH3 D/D information: Rx power |
| 1.3.6.1.4.1.4756.20.701.20.1.150 | Columnf10GMUXCH3DDTempRemote | read-only | current | Local FRM220-TM-10GMUX card CH3 D/D information: Temperature in degree C |
| 1.3.6.1.4.1.4756.20.701.20.1.151 | Columnf10GMUXCH3SupplyVolRemote | read-only | current | Local FRM220-TM-10GMUX card CH3 D/D information: SupplyVol |
| 1.3.6.1.4.1.4756.20.701.20.1.152 | Columnf10GMUXCH3TxLaserBiasRemote | read-only | current | Local FRM220-TM-10GMUX card CH3 D/D information: Tx LaserBias |
| 1.3.6.1.4.1.4756.20.701.20.1.153 | Columnf10GMUXCH4DDVendorRemote | read-only | current | Local FRM220-TM-10GMUX card CH4 D/D information: Vendor name |
| 1.3.6.1.4.1.4756.20.701.20.1.154 | Columnf10GMUXCH4DDPartNoRemote | read-only | current | Local FRM220-TM-10GMUX card CH4 D/D information: Vendor part number |
| 1.3.6.1.4.1.4756.20.701.20.1.155 | Columnf10GMUXCH4DDVendorSNRemote | read-only | current | Local FRM220-TM-10GMUX card CH4 D/D information: Vendor SN |
| 1.3.6.1.4.1.4756.20.701.20.1.156 | Columnf10GMUXCH4DDFiberTypeRemote | read-only | current | Local FRM220-TM-10GMUX card CH4 D/D information: Fiber Type |
| 1.3.6.1.4.1.4756.20.701.20.1.157 | Columnf10GMUXCH4DDWaveLenRemote | read-only | current | Local FRM220-TM-10GMUX card CH4 D/D information: Wave length |
| 1.3.6.1.4.1.4756.20.701.20.1.158 | Columnf10GMUXCH4DDWaveLen2Remote | read-only | current | Local FRM220-TM-10GMUX card CH4 D/D information: Wave length 2 |
| 1.3.6.1.4.1.4756.20.701.20.1.159 | Columnf10GMUXCH4DDLinkLenRemote | read-only | current | Local FRM220-TM-10GMUX card CH4 D/D information: Link length |
| 1.3.6.1.4.1.4756.20.701.20.1.160 | Columnf10GMUXCH4DDLenUnitRemote | read-only | current | Remote FRM220-10GMUX card CH4 D/D information: Length Unit |
| 1.3.6.1.4.1.4756.20.701.20.1.161 | Columnf10GMUXCH4DDRxSensRemote | read-only | current | Local FRM220-TM-10GMUX card CH4 D/D information: Rx Sensitivity |
| 1.3.6.1.4.1.4756.20.701.20.1.162 | Columnf10GMUXCH4DDTxPWRRemote | read-only | current | Local FRM220-TM-10GMUX card CH4 D/D information: Tx power |
| 1.3.6.1.4.1.4756.20.701.20.1.163 | Columnf10GMUXCH4DDRxPWRRemote | read-only | current | Local FRM220-TM-10GMUX card CH4 D/D information: Rx power |
| 1.3.6.1.4.1.4756.20.701.20.1.164 | Columnf10GMUXCH4DDTempRemote | read-only | current | Local FRM220-TM-10GMUX card CH4 D/D information: Temperature in degree C |
| 1.3.6.1.4.1.4756.20.701.20.1.165 | Columnf10GMUXCH4SupplyVolRemote | read-only | current | Local FRM220-TM-10GMUX card CH4 D/D information: SupplyVol |
| 1.3.6.1.4.1.4756.20.701.20.1.166 | Columnf10GMUXCH4TxLaserBiasRemote | read-only | current | Local FRM220-TM-10GMUX card CH4 D/D information: Tx LaserBias |
| 1.3.6.1.4.1.4756.20.701.20.1.167 | Columnf10GMUXCH5DDVendorRemote | read-only | current | Local FRM220-TM-10GMUX card CH5 D/D information: Vendor name |
| 1.3.6.1.4.1.4756.20.701.20.1.168 | Columnf10GMUXCH5DDPartNoRemote | read-only | current | Local FRM220-TM-10GMUX card CH5 D/D information: Vendor part number |
| 1.3.6.1.4.1.4756.20.701.20.1.169 | Columnf10GMUXCH5DDVendorSNRemote | read-only | current | Local FRM220-TM-10GMUX card CH5 D/D information: Vendor SN |
| 1.3.6.1.4.1.4756.20.701.20.1.170 | Columnf10GMUXCH5DDFiberTypeRemote | read-only | current | Local FRM220-TM-10GMUX card CH5 D/D information: Fiber Type |
| 1.3.6.1.4.1.4756.20.701.20.1.171 | Columnf10GMUXCH5DDWaveLenRemote | read-only | current | Local FRM220-TM-10GMUX card CH5 D/D information: Wave length |
| 1.3.6.1.4.1.4756.20.701.20.1.172 | Columnf10GMUXCH5DDWaveLen2Remote | read-only | current | Local FRM220-TM-10GMUX card CH5 D/D information: Wave length 2 |
| 1.3.6.1.4.1.4756.20.701.20.1.173 | Columnf10GMUXCH5DDLinkLenRemote | read-only | current | Local FRM220-TM-10GMUX card CH5 D/D information: Link length |
| 1.3.6.1.4.1.4756.20.701.20.1.174 | Columnf10GMUXCH5DDLenUnitRemote | read-only | current | Remote FRM220-10GMUX card CH5 D/D information: Length Unit |
| 1.3.6.1.4.1.4756.20.701.20.1.175 | Columnf10GMUXCH5DDRxSensRemote | read-only | current | Local FRM220-TM-10GMUX card CH5 D/D information: Rx Sensitivity |
| 1.3.6.1.4.1.4756.20.701.20.1.176 | Columnf10GMUXCH5DDTxPWRRemote | read-only | current | Local FRM220-TM-10GMUX card CH5 D/D information: Tx power |
| 1.3.6.1.4.1.4756.20.701.20.1.177 | Columnf10GMUXCH5DDRxPWRRemote | read-only | current | Local FRM220-TM-10GMUX card CH5 D/D information: Rx power |
| 1.3.6.1.4.1.4756.20.701.20.1.178 | Columnf10GMUXCH5DDTempRemote | read-only | current | Local FRM220-TM-10GMUX card CH5 D/D information: Temperature in degree C |
| 1.3.6.1.4.1.4756.20.701.20.1.179 | Columnf10GMUXCH5SupplyVolRemote | read-only | current | Local FRM220-TM-10GMUX card CH5 D/D information: SupplyVol |
| 1.3.6.1.4.1.4756.20.701.20.1.180 | Columnf10GMUXCH5TxLaserBiasRemote | read-only | current | Local FRM220-TM-10GMUX card CH5 D/D information: Tx LaserBias |
| 1.3.6.1.4.1.4756.20.701.20.1.181 | Columnf10GMUXCH6DDVendorRemote | read-only | current | Local FRM220-TM-10GMUX card CH6 D/D information: Vendor name |
| 1.3.6.1.4.1.4756.20.701.20.1.182 | Columnf10GMUXCH6DDPartNoRemote | read-only | current | Local FRM220-TM-10GMUX card CH6 D/D information: Vendor part number |
| 1.3.6.1.4.1.4756.20.701.20.1.183 | Columnf10GMUXCH6DDVendorSNRemote | read-only | current | Local FRM220-TM-10GMUX card CH6 D/D information: Vendor SN |
| 1.3.6.1.4.1.4756.20.701.20.1.184 | Columnf10GMUXCH6DDFiberTypeRemote | read-only | current | Local FRM220-TM-10GMUX card CH6 D/D information: Fiber Type |
| 1.3.6.1.4.1.4756.20.701.20.1.185 | Columnf10GMUXCH6DDWaveLenRemote | read-only | current | Local FRM220-TM-10GMUX card CH6 D/D information: Wave length |
| 1.3.6.1.4.1.4756.20.701.20.1.186 | Columnf10GMUXCH6DDWaveLen2Remote | read-only | current | Local FRM220-TM-10GMUX card CH6 D/D information: Wave length 2 |
| 1.3.6.1.4.1.4756.20.701.20.1.187 | Columnf10GMUXCH6DDLinkLenRemote | read-only | current | Local FRM220-TM-10GMUX card CH6 D/D information: Link length |
| 1.3.6.1.4.1.4756.20.701.20.1.188 | Columnf10GMUXCH6DDLenUnitRemote | read-only | current | Remote FRM220-10GMUX card CH6 D/D information: Length Unit |
| 1.3.6.1.4.1.4756.20.701.20.1.189 | Columnf10GMUXCH6DDRxSensRemote | read-only | current | Local FRM220-TM-10GMUX card CH6 D/D information: Rx Sensitivity |
| 1.3.6.1.4.1.4756.20.701.20.1.190 | Columnf10GMUXCH6DDTxPWRRemote | read-only | current | Local FRM220-TM-10GMUX card CH6 D/D information: Tx power |
| 1.3.6.1.4.1.4756.20.701.20.1.191 | Columnf10GMUXCH6DDRxPWRRemote | read-only | current | Local FRM220-TM-10GMUX card CH6 D/D information: Rx power |
| 1.3.6.1.4.1.4756.20.701.20.1.192 | Columnf10GMUXCH6DDTempRemote | read-only | current | Local FRM220-TM-10GMUX card CH6 D/D information: Temperature in degree C |
| 1.3.6.1.4.1.4756.20.701.20.1.193 | Columnf10GMUXCH6SupplyVolRemote | read-only | current | Local FRM220-TM-10GMUX card CH6 D/D information: SupplyVol |
| 1.3.6.1.4.1.4756.20.701.20.1.194 | Columnf10GMUXCH6TxLaserBiasRemote | read-only | current | Local FRM220-TM-10GMUX card CH6 D/D information: Tx LaserBias |
| 1.3.6.1.4.1.4756.20.701.20.1.195 | Columnf10GMUXCH7DDVendorRemote | read-only | current | Local FRM220-TM-10GMUX card CH7 D/D information: Vendor name |
| 1.3.6.1.4.1.4756.20.701.20.1.196 | Columnf10GMUXCH7DDPartNoRemote | read-only | current | Local FRM220-TM-10GMUX card CH7 D/D information: Vendor part number |
| 1.3.6.1.4.1.4756.20.701.20.1.197 | Columnf10GMUXCH7DDVendorSNRemote | read-only | current | Local FRM220-TM-10GMUX card CH7 D/D information: Vendor SN |
| 1.3.6.1.4.1.4756.20.701.20.1.198 | Columnf10GMUXCH7DDFiberTypeRemote | read-only | current | Local FRM220-TM-10GMUX card CH7 D/D information: Fiber Type |
| 1.3.6.1.4.1.4756.20.701.20.1.199 | Columnf10GMUXCH7DDWaveLenRemote | read-only | current | Local FRM220-TM-10GMUX card CH7 D/D information: Wave length |
| 1.3.6.1.4.1.4756.20.701.20.1.200 | Columnf10GMUXCH7DDWaveLen2Remote | read-only | current | Local FRM220-TM-10GMUX card CH7 D/D information: Wave length 2 |
| 1.3.6.1.4.1.4756.20.701.20.1.201 | Columnf10GMUXCH7DDLinkLenRemote | read-only | current | Local FRM220-TM-10GMUX card CH7 D/D information: Link length |
| 1.3.6.1.4.1.4756.20.701.20.1.202 | Columnf10GMUXCH7DDLenUnitRemote | read-only | current | Remote FRM220-10GMUX card CH7 D/D information: Length Unit |
| 1.3.6.1.4.1.4756.20.701.20.1.203 | Columnf10GMUXCH7DDRxSensRemote | read-only | current | Local FRM220-TM-10GMUX card CH7 D/D information: Rx Sensitivity |
| 1.3.6.1.4.1.4756.20.701.20.1.204 | Columnf10GMUXCH7DDTxPWRRemote | read-only | current | Local FRM220-TM-10GMUX card CH7 D/D information: Tx power |
| 1.3.6.1.4.1.4756.20.701.20.1.205 | Columnf10GMUXCH7DDRxPWRRemote | read-only | current | Local FRM220-TM-10GMUX card CH7 D/D information: Rx power |
| 1.3.6.1.4.1.4756.20.701.20.1.206 | Columnf10GMUXCH7DDTempRemote | read-only | current | Local FRM220-TM-10GMUX card CH7 D/D information: Temperature in degree C |
| 1.3.6.1.4.1.4756.20.701.20.1.207 | Columnf10GMUXCH7SupplyVolRemote | read-only | current | Local FRM220-TM-10GMUX card CH7 D/D information: SupplyVol |
| 1.3.6.1.4.1.4756.20.701.20.1.208 | Columnf10GMUXCH7TxLaserBiasRemote | read-only | current | Local FRM220-TM-10GMUX card CH7 D/D information: Tx LaserBias |
| 1.3.6.1.4.1.4756.20.701.20.1.209 | Columnf10GMUXDeviceActiveRemote | read-only | current | Local FRM220-TM-10GMUX card active: 0:Inactive 1:Active |
| 1.3.6.1.4.1.4756.20.701.20.1.210 | Columnf10GMUXClrCVCntsRemote | read-write | current | Clear local device card CV IN/OUT counters: 0:No action 1:Action |
| 1.3.6.1.4.1.4756.20.701.20.1.211 | Columnf10GMUXTunableLinechORfreqRemote | read-write | current | Local FRM220-TM-10GMUX card Tunable Line chORfreq Mode. 0: Channel 1: Frequency |
| 1.3.6.1.4.1.4756.20.701.20.1.212 | Columnf10GMUXTunableLineChannelRemote | read-write | current | Local FRM220-TM-10GMUX card Tunable Line Channel setting. |
| 1.3.6.1.4.1.4756.20.701.20.1.213 | Columnf10GMUXTunableLineFrequencyRemote | read-write | current | Local FRM220-TM-10GMUX card Tunable Line Frequency setting. |
| 1.3.6.1.4.1.4756.20.701.20.1.214 | Columnf10GMUXPowerLedRemote | read-only | current | Local FRM220-TM-10GMUX card Powe Led. 0:ON (Power ON) 1:Flash (Standby; 1s ON/1s OFF) |
| 1.3.6.1.4.1.4756.20.701.20.1.215 | Columnf10GMUXSystemLedRemote | read-only | current | Local FRM220-TM-10GMUX card Syetem Led. 0:OFF 1:Link up 2:ON |
| 1.3.6.1.4.1.4756.20.701.20.1.216 | Columnf10GMUXAlarmLedRemote | read-only | current | Local FRM220-TM-10GMUX card Alarm Led. 0:OFF 1:ON |
| 1.3.6.1.4.1.4756.20.701.20.1.217 | Columnf10GMUXLFPTLedRemote | read-only | current | Local FRM220-TM-10GMUX card LFPT Led. 0:OFF 1:ON |
| 1.3.6.1.4.1.4756.20.701.20.1.218 | Columnf10GMUXLineLedRemote | read-only | current | Local FRM220-TM-10GMUX card Line Led. 0:OFF(Link Down) 1:link up (On: 0.5s, Off: 0.5s) 2:LB (On: 1s, Off: 1s) 3:ON (0.5s ON/0.5s OFF) |
| 1.3.6.1.4.1.4756.20.701.20.1.219 | Columnf10GMUXCH1LedRemote | read-only | current | Local FRM220-TM-10GMUX card CH1 Led. 0:OFF(Link Down) 1:link up (On: 0.5s, Off: 0.5s) 2:LB (On: 1s, Off: 1s) 3:ON (0.5s ON/0.5s OFF) |
| 1.3.6.1.4.1.4756.20.701.20.1.220 | Columnf10GMUXCH2LedRemote | read-only | current | Local FRM220-TM-10GMUX card CH2 Led. 0:OFF(Link Down) 1:link up (On: 0.5s, Off: 0.5s) 2:LB (On: 1s, Off: 1s) 3:ON (0.5s ON/0.5s OFF) |
| 1.3.6.1.4.1.4756.20.701.20.1.221 | Columnf10GMUXCH3LedRemote | read-only | current | Local FRM220-TM-10GMUX card CH3 Led. 0:OFF(Link Down) 1:link up (On: 0.5s, Off: 0.5s) 2:LB (On: 1s, Off: 1s) 3:ON (0.5s ON/0.5s OFF) |
| 1.3.6.1.4.1.4756.20.701.20.1.222 | Columnf10GMUXCH4LedRemote | read-only | current | Local FRM220-TM-10GMUX card CH4 Led. 0:OFF(Link Down) 1:link up (On: 0.5s, Off: 0.5s) 2:LB (On: 1s, Off: 1s) 3:ON (0.5s ON/0.5s OFF) |
| 1.3.6.1.4.1.4756.20.701.20.1.223 | Columnf10GMUXCH5LedRemote | read-only | current | Local FRM220-TM-10GMUX card CH5 Led. 0:OFF(Link Down) 1:link up (On: 0.5s, Off: 0.5s) 2:LB (On: 1s, Off: 1s) 3:ON (0.5s ON/0.5s OFF) |
| 1.3.6.1.4.1.4756.20.701.20.1.224 | Columnf10GMUXCH6LedRemote | read-only | current | Local FRM220-TM-10GMUX card CH6 Led. 0:OFF(Link Down) 1:link up (On: 0.5s, Off: 0.5s) 2:LB (On: 1s, Off: 1s) 3:ON (0.5s ON/0.5s OFF) |
| 1.3.6.1.4.1.4756.20.701.20.1.225 | Columnf10GMUXCH7LedRemote | read-only | current | Local FRM220-TM-10GMUX card CH7 Led. 0:OFF(Link Down) 1:link up (On: 0.5s, Off: 0.5s) 2:LB (On: 1s, Off: 1s) 3:ON (0.5s ON/0.5s OFF) |
| 1.3.6.1.4.1.4756.20.710 | Nodef100GE2QCards | |||
| 1.3.6.1.4.1.4756.20.710.20 | Tablef100GE2QTable | not-accessible | current | A list of local Access 100G Line Card entries. The number of entries is Access 100G-No-L. |
| 1.3.6.1.4.1.4756.20.710.20.1 | Rowf100GE2QEntry | not-accessible | current | An entry containing management information applicable to a particular local Access 100G Line Card. |
| 1.3.6.1.4.1.4756.20.710.20.1.1 | Columnf100GE2QChassisIndex | read-only | current | A unique value for each local card. It is the chassis location number. |
| 1.3.6.1.4.1.4756.20.710.20.1.2 | Columnf100GE2QSlotIndex | read-only | current | A unique value for each local card. It is the slot location number. |
| 1.3.6.1.4.1.4756.20.710.20.1.3 | Columnf100GE2QCardHWVer | read-only | current | Local FRM220-100GE-2Q Line Card hardware version x.xxx |
| 1.3.6.1.4.1.4756.20.710.20.1.4 | Columnf100GE2QCardFWVer | read-only | current | Local FRM220-100GE-2Q Line Card firmware version x.xxx |
| 1.3.6.1.4.1.4756.20.710.20.1.5 | Columnf100GE2QCardCPLDVer | read-only | current | Local FRM220-100GE-2Q Line Card CPLD version x.xxx |
| 1.3.6.1.4.1.4756.20.710.20.1.6 | Columnf100GE2QCardFPGAVer | read-only | current | Local FRM220-100GE-2Q Line Card FPGA version x.xxx |
| 1.3.6.1.4.1.4756.20.710.20.1.7 | Columnf100GE2QPortReset | read-write | current | Local FRM220-100GE-2Q Line Card Port Reset feature: 0:Inactive 1:Active |
| 1.3.6.1.4.1.4756.20.710.20.1.8 | Columnf100GE2QSetDefault | read-write | current | Local FRM220-100GE-2Q Line Card Set to Default function: 0:Inactive 1:Active |
| 1.3.6.1.4.1.4756.20.710.20.1.9 | Columnf100GE2QLinePresent | read-only | current | Local FRM220-100GE-2Q Line Card Line Fiber Port Present: 0:NO 1:YES |
| 1.3.6.1.4.1.4756.20.710.20.1.10 | Columnf100GE2QClientPresent | read-only | current | Local FRM220-100GE-2Q Line Card Client Fiber Port Present: 0:NO 1:YES |
| 1.3.6.1.4.1.4756.20.710.20.1.11 | Columnf100GE2QLineLink | read-only | current | Local FRM220-100GE-2Q Line Card Line Fiber Port Link Status: 0:Down 1:Up |
| 1.3.6.1.4.1.4756.20.710.20.1.12 | Columnf100GE2QClientLink | read-only | current | Local FRM220-100GE-2Q Line Card Client Fiber Port Link Status: 0:Down 1:Up |
| 1.3.6.1.4.1.4756.20.710.20.1.13 | Columnf100GE2QLine1CDRLock | read-only | current | Local FRM220-100GE-2Q Line Card Line1 Fiber Port CDR Lock Status: 0:Not Locked 1:Locked |
| 1.3.6.1.4.1.4756.20.710.20.1.14 | Columnf100GE2QLine2CDRLock | read-only | current | Local FRM220-100GE-2Q Line Card Line2 Fiber Port CDR Lock Status: 0:Not Locked 1:Locked |
| 1.3.6.1.4.1.4756.20.710.20.1.15 | Columnf100GE2QLine3CDRLock | read-only | current | Local FRM220-100GE-2Q Line Card Line3 Fiber Port CDR Lock Status: 0:Not Locked 1:Locked |
| 1.3.6.1.4.1.4756.20.710.20.1.16 | Columnf100GE2QLine4CDRLock | read-only | current | Local FRM220-100GE-2Q Line Card Line4 Fiber Port CDR Lock Status: 0:Not Locked 1:Locked |
| 1.3.6.1.4.1.4756.20.710.20.1.17 | Columnf100GE2QClient1CDRLock | read-only | current | Local FRM220-100GE-2Q Line Card Client1 Fiber Port CDR Lock Status: 0:Not Locked 1:Locked |
| 1.3.6.1.4.1.4756.20.710.20.1.18 | Columnf100GE2QClient2CDRLock | read-only | current | Local FRM220-100GE-2Q Line Card Client2 Fiber Port CDR Lock Status: 0:Not Locked 1:Locked |
| 1.3.6.1.4.1.4756.20.710.20.1.19 | Columnf100GE2QClient3CDRLock | read-only | current | Local FRM220-100GE-2Q Line Card Client3 Fiber Port CDR Lock Status: 0:Not Locked 1:Locked |
| 1.3.6.1.4.1.4756.20.710.20.1.20 | Columnf100GE2QClient4CDRLock | read-only | current | Local FRM220-100GE-2Q Line Card Client4 Fiber Port CDR Lock Status: 0:Not Locked 1:Locked |
| 1.3.6.1.4.1.4756.20.710.20.1.21 | Columnf100GE2QLine1TxFault | read-only | current | Local FRM220-100GE-2Q Line Card Line1 Fiber Port Transmit Fault Status: 0:Normal 1:Failure |
| 1.3.6.1.4.1.4756.20.710.20.1.22 | Columnf100GE2QLine2TxFault | read-only | current | Local FRM220-100GE-2Q Line Card Line2 Fiber Port Transmit Fault Status: 0:Normal 1:Failure |
| 1.3.6.1.4.1.4756.20.710.20.1.23 | Columnf100GE2QLine3TxFault | read-only | current | Local FRM220-100GE-2Q Line Card Line3 Fiber Port Transmit Fault Status: 0:Normal 1:Failure |
| 1.3.6.1.4.1.4756.20.710.20.1.24 | Columnf100GE2QLine4TxFault | read-only | current | Local FRM220-100GE-2Q Line Card Line4 Fiber Port Transmit Fault Status: 0:Normal 1:Failure |
| 1.3.6.1.4.1.4756.20.710.20.1.25 | Columnf100GE2QClient1TxFault | read-only | current | Local FRM220-100GE-2Q Line Card Client1 Fiber Port Transmit Fault Status: 0:Normal 1:Failure |
| 1.3.6.1.4.1.4756.20.710.20.1.26 | Columnf100GE2QClient2TxFault | read-only | current | Local FRM220-100GE-2Q Line Card Client2 Fiber Port Transmit Fault Status: 0:Normal 1:Failure |
| 1.3.6.1.4.1.4756.20.710.20.1.27 | Columnf100GE2QClient3TxFault | read-only | current | Local FRM220-100GE-2Q Line Card Client3 Fiber Port Transmit Fault Status: 0:Normal 1:Failure |
| 1.3.6.1.4.1.4756.20.710.20.1.28 | Columnf100GE2QClient4TxFault | read-only | current | Local FRM220-100GE-2Q Line Card Client4 Fiber Port Transmit Fault Status: 0:Normal 1:Failure |
| 1.3.6.1.4.1.4756.20.710.20.1.29 | Columnf100GE2QPortActive | read-write | current | Local FRM220-100GE-2Q Line Card Port Active: 0:Disable 1:Enable |
| 1.3.6.1.4.1.4756.20.710.20.1.30 | Columnf100GE2QLineActive | read-write | current | Local FRM220-100GE-2Q Line Card Line Active: 0:Disable 1:Enable |
| 1.3.6.1.4.1.4756.20.710.20.1.31 | Columnf100GE2QClientActive | read-write | current | Local FRM220-100GE-2Q Line Card Client Active: 0:Disable 1:Enable |
| 1.3.6.1.4.1.4756.20.710.20.1.32 | Columnf100GE2QDataRateSts | read-only | current | Local FRM220-100GE-2Q Line Card Data Rate Status. |
| 1.3.6.1.4.1.4756.20.710.20.1.33 | Columnf100GE2QDataRate | read-write | current | Local FRM220-100GE-2Q Line Card Data Rate setting: 0:Ethernet 100GBaseR (PCS) 1:Ethernet 40GBaseR (PCS) |
| 1.3.6.1.4.1.4756.20.710.20.1.34 | Columnf100GE2QFEC | read-write | current | Local FRM220-100GE-2Q Line Card Data Rate setting: 0:Disable 1:Line side 2:Client side 3:Both side |
| 1.3.6.1.4.1.4756.20.710.20.1.35 | Columnf100GE2QLineLBT | read-write | current | Local FRM220-100GE-2Q Line Card Line LoopBack Test function setting: 0:Disable 1:Enable |
| 1.3.6.1.4.1.4756.20.710.20.1.36 | Columnf100GE2QClientLBT | read-write | current | Local FRM220-100GE-2Q Line Card Client LoopBack Test function setting: 0:Disable 1:Enable |
| 1.3.6.1.4.1.4756.20.710.20.1.37 | Columnf100GE2QLineALS | read-write | current | Local FRM220-100GE-2Q Line Card Line Auto Laser Shutdown setting: 0:Disable 1:Enable |
| 1.3.6.1.4.1.4756.20.710.20.1.38 | Columnf100GE2QClientALS | read-write | current | Local FRM220-100GE-2Q Line Card Client Auto Laser Shutdown setting: 0:Disable 1:Enable |
| 1.3.6.1.4.1.4756.20.710.20.1.39 | Columnf100GE2QQSFPLFP | read-write | current | Local FRM220-100GE-2Q Line Card both of Line and Client Loss Propagation setting: 0:Disable 1:Line 2:Client 3:Both |
| 1.3.6.1.4.1.4756.20.710.20.1.40 | Columnf100GE2QLineTxPacket | read-only | current | Local FRM220-100GE-2Q Line Card Line Tx Packet. |
| 1.3.6.1.4.1.4756.20.710.20.1.41 | Columnf100GE2QLineRxPacket | read-only | current | Local FRM220-100GE-2Q Line Card Line Rx Packet. |
| 1.3.6.1.4.1.4756.20.710.20.1.42 | Columnf100GE2QLineErrPacket | read-only | current | Local FRM220-100GE-2Q Line Card Line Error Packet. |
| 1.3.6.1.4.1.4756.20.710.20.1.43 | Columnf100GE2QClientTxPacket | read-only | current | Local FRM220-100GE-2Q Line Card Client Tx Packet. |
| 1.3.6.1.4.1.4756.20.710.20.1.44 | Columnf100GE2QClientRxPacket | read-only | current | Local FRM220-100GE-2Q Line Card Client Rx Packet. |
| 1.3.6.1.4.1.4756.20.710.20.1.45 | Columnf100GE2QClientErrPacket | read-only | current | Local FRM220-100GE-2Q Line Card Client Error Packet. |
| 1.3.6.1.4.1.4756.20.710.20.1.46 | Columnf100GE2QLineBERT | read-write | current | Local FRM220-100GE-2Q Line Card Line BERT setting: 0:All Disable 1:Packet Transmit Enable 2:Packet Receive Enable 3:All Enable |
| 1.3.6.1.4.1.4756.20.710.20.1.47 | Columnf100GE2QClientBERT | read-write | current | Local FRM220-100GE-2Q Line Card Client BERT setting: 0:All Disable 1:Packet Transmit Enable 2:Packet Receive Enable 3:All Enable |
| 1.3.6.1.4.1.4756.20.710.20.1.48 | Columnf100GE2QClrBERTCnt | read-write | current | Clear local device card Bert Counters: 0:No action 1:Action |
| 1.3.6.1.4.1.4756.20.710.20.1.49 | Columnf100GE2QLineVendorName | read-only | current | Local FRM220-100GE-2Q Line Card Line Vender Name. |
| 1.3.6.1.4.1.4756.20.710.20.1.50 | Columnf100GE2QLinePartNo | read-only | current | Local FRM220-100GE-2Q Line Card Line Part Number. |
| 1.3.6.1.4.1.4756.20.710.20.1.51 | Columnf100GE2QLineSerialNumber | read-only | current | Local FRM220-100GE-2Q Line Card Line Part Number. |
| 1.3.6.1.4.1.4756.20.710.20.1.52 | Columnf100GE2QLineTransceiver | read-only | current | 100G or 40G QSFP Plus Transceiver. 40G-Active-Cable-XLPPI 40GBASE-LR4 40GBASE-SR4 40GBASE-CR4 10GBASE-SR 10GBASE-LR 10GBASE-LRM Unspecified 100G AOC or 25GAUI … |
| 1.3.6.1.4.1.4756.20.710.20.1.53 | Columnf100GE2QLineTransceiver2 | read-only | current | 100G or 40G QSFP Plus Transceiver2. 40G OTN (OTU3B/OTU3C) OC 48, short reach OC 48, intermediate reach OC 48, long reach |
| 1.3.6.1.4.1.4756.20.710.20.1.54 | Columnf100GE2QLineTransceiver3 | read-only | current | 100G or 40G QSFP Plus Transceiver3. SAS 12.0G SAS 24.0G SAS 3.0G SAS 6.0G |
| 1.3.6.1.4.1.4756.20.710.20.1.55 | Columnf100GE2QLineConnectorType | read-only | current | 100G LINE Conncetor Type. Unknown SC FC-Style-1-copper-connector FC-Style-2-copper-connector BNC/TNC FC-coax-headers Fiberjack LC MT-RJ MU SG Optical-Pigtail M… |
| 1.3.6.1.4.1.4756.20.710.20.1.56 | Columnf100GE2QLineWaveLength1 | read-only | current | Local FRM220-100GE-2Q Line Card Line Wave Length 1. |
| 1.3.6.1.4.1.4756.20.710.20.1.57 | Columnf100GE2QLineWaveLength2 | read-only | current | Local FRM220-100GE-2Q Line Card Line Wave Length 2. |
| 1.3.6.1.4.1.4756.20.710.20.1.58 | Columnf100GE2QLineLinkLength | read-only | current | Local FRM220-100GE-2Q Line Card Line Link Length. |
| 1.3.6.1.4.1.4756.20.710.20.1.59 | Columnf100GE2QLineNominalBitRate | read-only | current | Local FRM220-100GE-2Q Line Card Line Nominal Bit Rate. |
| 1.3.6.1.4.1.4756.20.710.20.1.60 | Columnf100GE2QLineTemp | read-only | current | Local FRM220-100GE-2Q Line Card Line Temperature. |
| 1.3.6.1.4.1.4756.20.710.20.1.61 | Columnf100GE2QLineSupplyVol | read-only | current | Local FRM220-100GE-2Q Line Card Line Supply Voltage. |
| 1.3.6.1.4.1.4756.20.710.20.1.62 | Columnf100GE2QLineTxMaxPower | read-only | current | Local FRM220-100GE-2Q Line Card Line Tx Max Power. |
| 1.3.6.1.4.1.4756.20.710.20.1.63 | Columnf100GE2QLineRxMaxPower | read-only | current | Local FRM220-100GE-2Q Line Card Line Rx Max Power. |
| 1.3.6.1.4.1.4756.20.710.20.1.64 | Columnf100GE2QLinePowerClass | read-only | current | Local FRM220-100GE-2Q Line Card Line Power Class. |
| 1.3.6.1.4.1.4756.20.710.20.1.65 | Columnf100GE2QLine1TxPower | read-only | current | Local FRM220-100GE-2Q Line Card Line1 Transmit Power. |
| 1.3.6.1.4.1.4756.20.710.20.1.66 | Columnf100GE2QLine1RxPower | read-only | current | Local FRM220-100GE-2Q Line Card Line1 Receive Power. |
| 1.3.6.1.4.1.4756.20.710.20.1.67 | Columnf100GE2QLine1TxLaserBias | read-only | current | Local FRM220-100GE-2Q Line Card Line1 Transmit Laser BIAS. |
| 1.3.6.1.4.1.4756.20.710.20.1.68 | Columnf100GE2QLine2TxPower | read-only | current | Local FRM220-100GE-2Q Line Card Line2 Transmit Power. |
| 1.3.6.1.4.1.4756.20.710.20.1.69 | Columnf100GE2QLine2RxPower | read-only | current | Local FRM220-100GE-2Q Line Card Line2 Receive Power. |
| 1.3.6.1.4.1.4756.20.710.20.1.70 | Columnf100GE2QLine2TxLaserBias | read-only | current | Local FRM220-100GE-2Q Line Card Line2 Transmit Laser BIAS. |
| 1.3.6.1.4.1.4756.20.710.20.1.71 | Columnf100GE2QLine3TxPower | read-only | current | Local FRM220-100GE-2Q Line Card Line3 Transmit Power. |
| 1.3.6.1.4.1.4756.20.710.20.1.72 | Columnf100GE2QLine3RxPower | read-only | current | Local FRM220-100GE-2Q Line Card Line3 Receive Power. |
| 1.3.6.1.4.1.4756.20.710.20.1.73 | Columnf100GE2QLine3TxLaserBias | read-only | current | Local FRM220-100GE-2Q Line Card Line3 Transmit Laser BIAS. |
| 1.3.6.1.4.1.4756.20.710.20.1.74 | Columnf100GE2QLine4TxPower | read-only | current | Local FRM220-100GE-2Q Line Card Line4 Transmit Power. |
| 1.3.6.1.4.1.4756.20.710.20.1.75 | Columnf100GE2QLine4RxPower | read-only | current | Local FRM220-100GE-2Q Line Card Line4 Receive Power. |
| 1.3.6.1.4.1.4756.20.710.20.1.76 | Columnf100GE2QLine4TxLaserBias | read-only | current | Local FRM220-100GE-2Q Line Card Line4 Transmit Laser BIAS. |
| 1.3.6.1.4.1.4756.20.710.20.1.77 | Columnf100GE2QLineTxPowerSum | read-only | current | Local FRM220-100GE-2Q Line Card Line Tx Power Sum. |
| 1.3.6.1.4.1.4756.20.710.20.1.78 | Columnf100GE2QLineRxPowerSum | read-only | current | Local FRM220-100GE-2Q Line Card Line Rx Power Sum. |
| 1.3.6.1.4.1.4756.20.710.20.1.79 | Columnf100GE2QClientVendorName | read-only | current | Local FRM220-100GE-2Q Line Card Client Vender Name. |
| 1.3.6.1.4.1.4756.20.710.20.1.80 | Columnf100GE2QClientPartNo | read-only | current | Local FRM220-100GE-2Q Line Card Client Part Number. |
| 1.3.6.1.4.1.4756.20.710.20.1.81 | Columnf100GE2QClientSerialNumber | read-only | current | Local FRM220-100GE-2Q Line Card Client Serial Number. |
| 1.3.6.1.4.1.4756.20.710.20.1.82 | Columnf100GE2QClientTransceiver | read-only | current | 100G or 40G QSFP Plus Transceiver. 40G-Active-Cable-XLPPI 40GBASE-LR4 40GBASE-SR4 40GBASE-CR4 10GBASE-SR 10GBASE-LR 10GBASE-LRM Unspecified 100G AOC or 25GAUI … |
| 1.3.6.1.4.1.4756.20.710.20.1.83 | Columnf100GE2QClientTransceiver2 | read-only | current | 100G or 40G QSFP Plus Transceiver2. 40G OTN (OTU3B/OTU3C) OC 48, short reach OC 48, intermediate reach OC 48, long reach |
| 1.3.6.1.4.1.4756.20.710.20.1.84 | Columnf100GE2QClientTransceiver3 | read-only | current | 100G or 40G QSFP Plus Transceiver3. SAS 12.0G SAS 24.0G SAS 3.0G SAS 6.0G |
| 1.3.6.1.4.1.4756.20.710.20.1.85 | Columnf100GE2QClientConnectorType | read-only | current | 100G or 40G Client Conncetor Type. Unknown SC FC-Style-1-copper-connector FC-Style-2-copper-connector BNC/TNC FC-coax-headers Fiberjack LC MT-RJ MU SG Optical-… |
| 1.3.6.1.4.1.4756.20.710.20.1.86 | Columnf100GE2QClientWaveLength1 | read-only | current | Local FRM220-100GE-2Q Line Card Client Wave Length 1. |
| 1.3.6.1.4.1.4756.20.710.20.1.87 | Columnf100GE2QClientWaveLength2 | read-only | current | Local FRM220-100GE-2Q Line Card Client Wave Length 2. |
| 1.3.6.1.4.1.4756.20.710.20.1.88 | Columnf100GE2QClientLinkLength | read-only | current | Local FRM220-100GE-2Q Line Card Client Link Length. |
| 1.3.6.1.4.1.4756.20.710.20.1.89 | Columnf100GE2QClientNominalBitRate | read-only | current | Local FRM220-100GE-2Q Line Card Client Nominal Bit Rate. |
| 1.3.6.1.4.1.4756.20.710.20.1.90 | Columnf100GE2QClientTemp | read-only | current | Local FRM220-100GE-2Q Line Card Client Temperature. |
| 1.3.6.1.4.1.4756.20.710.20.1.91 | Columnf100GE2QClientSupplyVol | read-only | current | Local FRM220-100GE-2Q Line Card Client Supply Voltage. |
| 1.3.6.1.4.1.4756.20.710.20.1.92 | Columnf100GE2QClientTxMaxPower | read-only | current | Local FRM220-100GE-2Q Line Card Client Tx Max Power. |
| 1.3.6.1.4.1.4756.20.710.20.1.93 | Columnf100GE2QClientRxMaxPower | read-only | current | Local FRM220-100GE-2Q Line Card Client Rx Max Power. |
| 1.3.6.1.4.1.4756.20.710.20.1.94 | Columnf100GE2QClientPowerClass | read-only | current | Local FRM220-100GE-2Q Line Card Client Power Class. |
| 1.3.6.1.4.1.4756.20.710.20.1.95 | Columnf100GE2QClient1TxPower | read-only | current | Local FRM220-100GE-2Q Line Card Client1 Transmit Power. |
| 1.3.6.1.4.1.4756.20.710.20.1.96 | Columnf100GE2QClient1RxPower | read-only | current | Local FRM220-100GE-2Q Line Card Client1 Receive Power. |
| 1.3.6.1.4.1.4756.20.710.20.1.97 | Columnf100GE2QClient1TxLaserBias | read-only | current | Local FRM220-100GE-2Q Line Card Client1 Transmit Laser BIAS. |
| 1.3.6.1.4.1.4756.20.710.20.1.98 | Columnf100GE2QClient2TxPower | read-only | current | Local FRM220-100GE-2Q Line Card Client2 Transmit Power. |
| 1.3.6.1.4.1.4756.20.710.20.1.99 | Columnf100GE2QClient2RxPower | read-only | current | Local FRM220-100GE-2Q Line Card Client2 Receive Power. |
| 1.3.6.1.4.1.4756.20.710.20.1.100 | Columnf100GE2QClient2TxLaserBias | read-only | current | Local FRM220-100GE-2Q Line Card Client2 Transmit Laser BIAS. |
| 1.3.6.1.4.1.4756.20.710.20.1.101 | Columnf100GE2QClient3TxPower | read-only | current | Local FRM220-100GE-2Q Line Card Client3 Transmit Power. |
| 1.3.6.1.4.1.4756.20.710.20.1.102 | Columnf100GE2QClient3RxPower | read-only | current | Local FRM220-100GE-2Q Line Card Client3 Receive Power. |
| 1.3.6.1.4.1.4756.20.710.20.1.103 | Columnf100GE2QClient3TxLaserBias | read-only | current | Local FRM220-100GE-2Q Line Card Client3 Transmit Laser BIAS. |
| 1.3.6.1.4.1.4756.20.710.20.1.104 | Columnf100GE2QClient4TxPower | read-only | current | Local FRM220-100GE-2Q Line Card Client4 Transmit Power. |
| 1.3.6.1.4.1.4756.20.710.20.1.105 | Columnf100GE2QClient4RxPower | read-only | current | Local FRM220-100GE-2Q Line Card Client4 Receive Power. |
| 1.3.6.1.4.1.4756.20.710.20.1.106 | Columnf100GE2QClient4TxLaserBias | read-only | current | Local FRM220-100GE-2Q Line Card Client4 Transmit Laser BIAS. |
| 1.3.6.1.4.1.4756.20.710.20.1.107 | Columnf100GE2QClientTxPowerSum | read-only | current | Local FRM220-100GE-2Q Line Card Client Tx Power Sum. |
| 1.3.6.1.4.1.4756.20.710.20.1.108 | Columnf100GE2QClientRxPowerSum | read-only | current | Local FRM220-100GE-2Q Line Card Client Rx Power Sum. |
| 1.3.6.1.4.1.4756.20.710.20.1.109 | Columnf100GE2QLineLinkAlm | read-write | current | Local FRM220-100GE-2Q Line Card Line Link Alarm setting: 0:Disable 1:Enable |
| 1.3.6.1.4.1.4756.20.710.20.1.110 | Columnf100GE2QClientLinkAlm | read-write | current | Local FRM220-100GE-2Q Line Card Client Link Alarm setting: 0:Disable 1:Enable |
| 1.3.6.1.4.1.4756.20.710.20.1.111 | Columnf100GE2QLine1LockAlm | read-write | current | Local FRM220-100GE-2Q Line Card Line 1 Lock Alarm setting: 0:Disable 1:Enable |
| 1.3.6.1.4.1.4756.20.710.20.1.112 | Columnf100GE2QLine2LockAlm | read-write | current | Local FRM220-100GE-2Q Line Card Line 2 Lock Alarm setting: 0:Disable 1:Enable |
| 1.3.6.1.4.1.4756.20.710.20.1.113 | Columnf100GE2QLine3LockAlm | read-write | current | Local FRM220-100GE-2Q Line Card Line 3 Lock Alarm setting: 0:Disable 1:Enable |
| 1.3.6.1.4.1.4756.20.710.20.1.114 | Columnf100GE2QLine4LockAlm | read-write | current | Local FRM220-100GE-2Q Line Card Line 4 Lock Alarm setting: 0:Disable 1:Enable |
| 1.3.6.1.4.1.4756.20.710.20.1.115 | Columnf100GE2QClient1LockAlm | read-write | current | Local FRM220-100GE-2Q Line Card Client 1 Lock Alarm setting: 0:Disable 1:Enable |
| 1.3.6.1.4.1.4756.20.710.20.1.116 | Columnf100GE2QClient2LockAlm | read-write | current | Local FRM220-100GE-2Q Line Card Client 2 Lock Alarm setting: 0:Disable 1:Enable |
| 1.3.6.1.4.1.4756.20.710.20.1.117 | Columnf100GE2QClient3LockAlm | read-write | current | Local FRM220-100GE-2Q Line Card Client 3 Lock Alarm setting: 0:Disable 1:Enable |
| 1.3.6.1.4.1.4756.20.710.20.1.118 | Columnf100GE2QClient4LockAlm | read-write | current | Local FRM220-100GE-2Q Line Card Client 4 Lock Alarm setting: 0:Disable 1:Enable |
| 1.3.6.1.4.1.4756.20.720 | NodeoaboapCards | |||
| 1.3.6.1.4.1.4756.20.720.20 | TableoaboapTable | not-accessible | current | A list of local oaboap card entries. The number of entries is accessEDFA-No-L. |
| 1.3.6.1.4.1.4756.20.720.20.1 | RowoaboapEntry | not-accessible | current | An entry containing management information applicable to a particular local FRM220 oaboap card. |
| 1.3.6.1.4.1.4756.20.720.20.1.1 | ColumnoaboapChassisIndex | read-only | current | A unique value for each local card. It is the chassis location number. |
| 1.3.6.1.4.1.4756.20.720.20.1.2 | ColumnoaboapSlotIndex | read-only | current | A unique value for each local card. It is the slot location number. |
| 1.3.6.1.4.1.4756.20.720.20.1.3 | ColumnoaboapCardHWVer | read-only | current | Local FRM220 OABOAP card hardware version x.xxx |
| 1.3.6.1.4.1.4756.20.720.20.1.4 | ColumnoaboapCardFWVer | read-only | current | Local FRM220 OABOAP card firmware version x.xxx |
| 1.3.6.1.4.1.4756.20.720.20.1.5 | ColumnoaboapCardCPLDVer | read-only | current | Local FRM220 OABOAP card CPLD version x.xxx |
| 1.3.6.1.4.1.4756.20.720.20.1.6 | ColumnoaboapCardFPGAVer | read-only | current | Local FRM220 OABOAP card FPGA version x.xxx |
| 1.3.6.1.4.1.4756.20.720.20.1.7 | ColumnoaboapModel | read-only | current | Local CardType: 0:FRM220-OAB21 1:FRM220-OAB21A 2:FRM220-OAP10 3:FRM220-OAP17 |
| 1.3.6.1.4.1.4756.20.720.20.1.8 | ColumnoaboapGain | read-only | current | Local Frm220 OABOAP Gain (Unit is dB) |
| 1.3.6.1.4.1.4756.20.720.20.1.9 | ColumnoaboapInputPowerAlarmLevel | read-only | current | Local Frm220 OABOAP Input Power Alarm Level (Unit is dBm) |
| 1.3.6.1.4.1.4756.20.720.20.1.10 | ColumnoaboapOutputPowerAlarmLevel | read-only | current | Local Frm220 OABOAP Output Power Alarm Level (Unit is dBm) |
| 1.3.6.1.4.1.4756.20.720.20.1.11 | ColumnoaboapOpticalInputPower | read-only | current | Local Frm220 OABOAP Optical Input Power (Unit is dBm) Loss |
| 1.3.6.1.4.1.4756.20.720.20.1.12 | ColumnoaboapOpticaloutputPower | read-only | current | Local Frm220 OABOAP Optical Output Power (Unit is dBm) Loss |
| 1.3.6.1.4.1.4756.20.720.20.1.13 | ColumnoaboapOpticalInputPowerAlarm | read-only | current | Local Frm220 OABOAP Optical Input Power Alarm: 0:normal 1:Abnormal |
| 1.3.6.1.4.1.4756.20.720.20.1.14 | ColumnoaboapOpticaloutputPowerAlarm | read-only | current | Local Frm220 OABOAP Optical Input Power Alarm: 0:normal 1:Abnormal |
| 1.3.6.1.4.1.4756.20.720.20.1.15 | ColumnoaboapTemperatureHighStatus | read-only | current | Local Frm220 OABOAP card temperature Status (Unit is degree C) |
| 1.3.6.1.4.1.4756.20.720.20.1.16 | ColumnoaboapTemperatureHighAlarm | read-only | current | Local Frm220 OABOAP card temperature Alarm: 0:normal 1:Abnormal |
| 1.3.6.1.4.1.4756.20.720.20.1.17 | ColumnoaboapLDBiasAlarm | read-only | current | Local Frm220 OABOAP card LD Bias Alarm: 0:normal 1:Abnormal |
| 1.3.6.1.4.1.4756.20.720.20.1.18 | ColumnoaboapGainPower | read-write | current | Local Frm220 OABOAP card set gain power (Unit is dB) |
| 1.3.6.1.4.1.4756.20.720.20.1.19 | ColumnoaboapInputPower | read-write | current | Local Frm220 OABOAP card set input power (Unit is dBm) |
| 1.3.6.1.4.1.4756.20.720.20.1.20 | ColumnoaboapOutputPower | read-write | current | Local Frm220 OABOAP card set output power(Unit is dBm) |
| 1.3.6.1.4.1.4756.20.720.20.1.21 | ColumnoaboapDeviceActive | read-write | current | Local Frm220 OABOAP card device active: 0:Disable 1:Enable |
| 1.3.6.1.4.1.4756.20.720.20.1.22 | ColumnoaboapDeviceReset | read-write | current | Local Frm220 OABOAP card device reset: 0:Off 1:Action |
| 1.3.6.1.4.1.4756.20.720.20.1.23 | ColumnoaboapSetDefault | read-write | current | Local Frm220 OABOAP set to default: 0:Off 1:Action |
| 1.3.6.1.4.1.4756.20.720.20.1.24 | ColumnoaboapTemperatureAlarm | read-only | current | Local Frm220 OABOAP card Temperature Alarm: 0:normal 1:Abnormal |
| 1.3.6.1.4.1.4756.20.720.20.1.25 | ColumnoaboapShutdownAlarm | read-only | current | Local Frm220 OABOAP card Shutdown Alarm: 0:normal 1:Abnormal |
| 1.3.6.1.4.1.4756.20.720.20.1.26 | ColumnoaboapDefaultAlarm | read-only | current | Local Frm220 OABOAP card Default SW Alarm: 0:normal 1:Abnormal |
| 1.3.6.1.4.1.4756.20.720.20.1.27 | ColumnoaboapInputOverAlarm | read-only | current | Local Frm220 OABOAP card InputOver Alarm: 0:normal 1:Abnormal |
| 1.3.6.1.4.1.4756.20.720.20.1.28 | ColumnoaboapOutputOverAlarm | read-only | current | Local Frm220 OABOAP card OutputOver Alarm: 0:normal 1:Abnormal |
| 1.3.6.1.4.1.4756.20.720.20.1.29 | ColumnoaboapPowerLed | read-only | current | Local Frm220 OABOAP card Powe Led. 0:ON (Power ON) 1:Flash (Standby; 1s ON/1s OFF) |
| 1.3.6.1.4.1.4756.20.720.20.1.30 | ColumnoaboapSystemLed | read-only | current | Local Frm220 OABOAP card Syetem Led. 0:OFF 1:ON 2:Flash |
| 1.3.6.1.4.1.4756.20.720.20.1.31 | ColumnoaboapInputLed | read-only | current | Local Frm220 OABOAP card Input Led. 0:OFF 1:Green(Normal) 2:Red(PWR_InLow / InPWR_Fail) |
| 1.3.6.1.4.1.4756.20.720.20.1.32 | ColumnoaboapOutputLed | read-only | current | Local Frm220 OABOAP card Output Led. 0:OFF 1:Green(Normal) 2:Red(PWR_OuLow / OuPWR_Fail) |
| 1.3.6.1.4.1.4756.20.720.20.1.33 | ColumnoaboapAlarmLed | read-only | current | Local Frm220 OABOAP card Alarm Led. 0:OFF 1:ON |
| 1.3.6.1.4.1.4756.20.720.20.1.34 | ColumnoaboapMgmtLed | read-only | current | Local Frm220 OABOAP card Mgmt Led. 0:OFF 1:ON |
| 1.3.6.1.4.1.4756.20.720.20.1.35 | ColumnoaboapAlarm | read-write | current | Local Frm220 OABOAP card Alarm Disable/Enable. 0:disable 1:enable |
| 1.3.6.1.4.1.4756.20.730 | Nodef2000EASLocalCards | |||
| 1.3.6.1.4.1.4756.20.730.20 | Tablef2000EASLocalTable | not-accessible | current | A list of Local FRM220A-2000EAS series card entries. |
| 1.3.6.1.4.1.4756.20.730.20.1 | Rowf2000EASLocalEntry | not-accessible | current | An entry containing management information applicable to a particular FRM220A-2000EAS series card. |
| 1.3.6.1.4.1.4756.20.730.20.1.1 | Columnf2000EASChassisIndexLocal | read-only | current | A unique value for each card. It starts from 0 to 9 contiguously. |
| 1.3.6.1.4.1.4756.20.730.20.1.2 | Columnf2000EASSlotIndexLocal | read-only | current | A unique value for each card. It starts from 1 to 20 contiguously. |
| 1.3.6.1.4.1.4756.20.730.20.1.3 | Columnf2000EASCardHWVerLocal | read-only | current | f2000EAS Series card hardware version x.xxx |
| 1.3.6.1.4.1.4756.20.730.20.1.4 | Columnf2000EASCardFWVerLocal | read-only | current | f2000EAS Series card firmware version x.xxx |
| 1.3.6.1.4.1.4756.20.730.20.1.5 | Columnf2000EASCardCPLDVerLocal | read-only | current | f2000EAS Series card CPLD version x.xxx |
| 1.3.6.1.4.1.4756.20.730.20.1.6 | Columnf2000EASCardFPGAVerLocal | read-only | current | f2000EAS Series card FPGA version x.xxx |
| 1.3.6.1.4.1.4756.20.730.20.1.7 | Columnf2000EASModelLocal | read-only | current | Card Type: 0:2000EAS/4F 1:2000EAS/2F 2:2000EAS/1F |
| 1.3.6.1.4.1.4756.20.730.20.1.8 | Columnf2000EASDNSServerTypeLocal | read-write | current | f2000EAS Series card IP Configuration: This setting controls the DNS name resolution done by the switch. The following modes are supported: 0:No DNS server No … |
| 1.3.6.1.4.1.4756.20.730.20.1.9 | Columnf2000EASDNSServerSettingLocal | read-write | current | f2000EAS Series card IP Configuration: If iDNSServerType setting '3:Configured',this value must setting IP address format as below: Dotted Decimal Notation ref… |
| 1.3.6.1.4.1.4756.20.730.20.1.10 | Columnf2000EASDNSproxyLocal | read-write | current | f2000EAS Series card IP Configuration: When DNS proxy is enabled, system will relay DNS requests to the currently configured DNS server, and reply as a DNS res… |
| 1.3.6.1.4.1.4756.20.730.20.1.11 | Columnf2000EASAddIPV4InterfaceLocal | read-write | current | f2000EAS Series card IP Interfaces: Add a new IP VLAN Interface: Syntax: [<Interface>] [<vlan_list>] [<IPV4_Addr>] [<IPV4_MASK>] Interface : 1~4 |
| 1.3.6.1.4.1.4756.20.730.20.1.12 | Columnf2000EASDeleteInterfaceLocal | read-write | current | f2000EAS Series card IP Interfaces: Delete a IPv4/v6 VLAN Interface: Syntax: [<Interface>] Interface: 1~4 |
| 1.3.6.1.4.1.4756.20.730.20.1.13 | Columnf2000EASIPInterface1VLANLocal | read-only | current | f2000EAS Series card IP Interfaces: The VLAN associated with the IP interface. Only ports in this VLAN will be able to access the IP interface. This field is o… |
| 1.3.6.1.4.1.4756.20.730.20.1.14 | Columnf2000EASIPInterface1DHCPLocal | read-write | current | f2000EAS Series card IP Interfaces: DHCP |
| 1.3.6.1.4.1.4756.20.730.20.1.15 | Columnf2000EASIPInterface1FallbackLocal | read-write | current | f2000EAS Series card IP Interfaces: Fallback |
| 1.3.6.1.4.1.4756.20.730.20.1.16 | Columnf2000EASIPInterface1IPV4CurrentLeaseLocal | read-only | current | f2000EAS Series card IP Interfaces: IPV4 Current Lease Address |
| 1.3.6.1.4.1.4756.20.730.20.1.17 | Columnf2000EASIPInterface1IPV4AddressLocal | read-only | current | f2000EAS Series card IP Interfaces: IPV4 Address |
| 1.3.6.1.4.1.4756.20.730.20.1.18 | Columnf2000EASIPInterface1IPV4MASKLenLocal | read-only | current | f2000EAS Series card IP Interfaces: IPV4 MASK Length |
| 1.3.6.1.4.1.4756.20.730.20.1.19 | Columnf2000EASIPInterface2VLANLocal | read-only | current | f2000EAS Series card IP Interfaces: The VLAN associated with the IP interface. Only ports in this VLAN will be able to access the IP interface. This field is o… |
| 1.3.6.1.4.1.4756.20.730.20.1.20 | Columnf2000EASIPInterface2DHCPLocal | read-write | current | f2000EASEDD Series card IP Interfaces: DHCP |
| 1.3.6.1.4.1.4756.20.730.20.1.21 | Columnf2000EASIPInterface2FallbackLocal | read-write | current | f2000EASEDD Series card IP Interfaces: Fallback |
| 1.3.6.1.4.1.4756.20.730.20.1.22 | Columnf2000EASIPInterface2IPV4CurrentLeaseLocal | read-only | current | f2000EAS Series card IP Interfaces: IPV4 Current Lease Address |
| 1.3.6.1.4.1.4756.20.730.20.1.23 | Columnf2000EASIPInterface2IPV4AddressLocal | read-only | current | f2000EAS Series card IP Interfaces: IPV4 Address |
| 1.3.6.1.4.1.4756.20.730.20.1.24 | Columnf2000EASIPInterface2IPV4MASKLenLocal | read-only | current | f2000EAS Series card IP Interfaces: IPV4 MASK Length |
| 1.3.6.1.4.1.4756.20.730.20.1.25 | Columnf2000EASIPInterface3VLANLocal | read-only | current | f2000EAS Series card IP Interfaces: The VLAN associated with the IP interface. Only ports in this VLAN will be able to access the IP interface. This field is o… |
| 1.3.6.1.4.1.4756.20.730.20.1.26 | Columnf2000EASIPInterface3DHCPLocal | read-write | current | f2000EAS Series card IP Interfaces: DHCP |
| 1.3.6.1.4.1.4756.20.730.20.1.27 | Columnf2000EASIPInterface3FallbackLocal | read-write | current | f2000EAS Series card IP Interfaces: Fallback |
| 1.3.6.1.4.1.4756.20.730.20.1.28 | Columnf2000EASIPInterface3IPV4CurrentLeaseLocal | read-only | current | f2000EAS Series card IP Interfaces: IPV4 Current Lease Address |
| 1.3.6.1.4.1.4756.20.730.20.1.29 | Columnf2000EASIPInterface3IPV4AddressLocal | read-only | current | f2000EAS Series card IP Interfaces: IPV4 Address |
| 1.3.6.1.4.1.4756.20.730.20.1.30 | Columnf2000EASIPInterface3IPV4MASKLenLocal | read-only | current | f2000EAS Series card IP Interfaces: IPV4 MASK Length |
| 1.3.6.1.4.1.4756.20.730.20.1.31 | Columnf2000EASIPInterface4VLANLocal | read-only | current | f2000EAS Series card IP Interfaces: The VLAN associated with the IP interface. Only ports in this VLAN will be able to access the IP interface. This field is o… |
| 1.3.6.1.4.1.4756.20.730.20.1.32 | Columnf2000EASIPInterface4DHCPLocal | read-write | current | f2000EAS Series card IP Interfaces: DHCP |
| 1.3.6.1.4.1.4756.20.730.20.1.33 | Columnf2000EASIPInterface4FallbackLocal | read-write | current | f2000EAS Series card IP Interfaces: Fallback |
| 1.3.6.1.4.1.4756.20.730.20.1.34 | Columnf2000EASIPInterface4IPV4CurrentLeaseLocal | read-only | current | f2000EAS Series card IP Interfaces: IPV4 Current Lease Address |
| 1.3.6.1.4.1.4756.20.730.20.1.35 | Columnf2000EASIPInterface4IPV4AddressLocal | read-only | current | f2000EAS Series card IP Interfaces: IPV4 Address |
| 1.3.6.1.4.1.4756.20.730.20.1.36 | Columnf2000EASIPInterface4IPV4MASKLenLocal | read-only | current | f2000EAS Series card IP Interfaces: IPV4 MASK Length |
| 1.3.6.1.4.1.4756.20.730.20.1.37 | Columnf2000EASAddIPV6InterfaceLocal | read-write | current | f2000EAS Series card IP Interfaces: Add a new IPv6 VLAN Interface: Syntax: [<Interface>] [<vlan_list>] [<IPV4_Addr>] [<IPV4_MASK>] Interface : 1~4 |
| 1.3.6.1.4.1.4756.20.730.20.1.38 | Columnf2000EASIPInterface1IPV6DHCPLocal | read-write | current | f2000EAS Series card IP Interfaces: IPV6 DHCP |
| 1.3.6.1.4.1.4756.20.730.20.1.39 | Columnf2000EASIPInterface1IPV6RapidCommitLocal | read-write | current | f2000EAS Series card IP Interfaces1: IPV6 RapidCommit |
| 1.3.6.1.4.1.4756.20.730.20.1.40 | Columnf2000EASIPInterface1IPV6CurrentLeaseLocal | read-only | current | f2000EAS Series card IP Interfaces: IPV6 Current lease Address |
| 1.3.6.1.4.1.4756.20.730.20.1.41 | Columnf2000EASIPInterface1IPV6AddressLocal | read-only | current | f2000EAS Series card IP Interfaces: IPV6 Address |
| 1.3.6.1.4.1.4756.20.730.20.1.42 | Columnf2000EASIPInterface1IPV6MASKLenLocal | read-only | current | f2000EAS Series card IP Interfaces: IPV6 MASK Length |
| 1.3.6.1.4.1.4756.20.730.20.1.43 | Columnf2000EASIPInterface2IPV6DHCPLocal | read-write | current | f2000EAS Series card IP Interfaces2: IPV6 DHCP |
| 1.3.6.1.4.1.4756.20.730.20.1.44 | Columnf2000EASIPInterface2IPV6RapidCommitLocal | read-write | current | f2000EAS Series card IP Interfaces2: IPV6 RapidCommit |
| 1.3.6.1.4.1.4756.20.730.20.1.45 | Columnf2000EASIPInterface2IPV6CurrentLeaseLocal | read-only | current | f2000EAS Series card IP Interfaces: IPV6 Current lease Address |
| 1.3.6.1.4.1.4756.20.730.20.1.46 | Columnf2000EASIPInterface2IPV6AddressLocal | read-only | current | f2000EAS Series card IP Interfaces: IPV6 Address |
| 1.3.6.1.4.1.4756.20.730.20.1.47 | Columnf2000EASIPInterface2IPV6MASKLenLocal | read-only | current | f2000EAS Series card IP Interfaces: IPV6 MASK Length |
| 1.3.6.1.4.1.4756.20.730.20.1.48 | Columnf2000EASIPInterface3IPV6DHCPLocal | read-write | current | f2000EAS Series card IP Interfaces2: IPV6 DHCP |
| 1.3.6.1.4.1.4756.20.730.20.1.49 | Columnf2000EASIPInterface3IPV6RapidCommitLocal | read-write | current | f2000EAS Series card IP Interfaces3: IPV6 RapidCommit |
| 1.3.6.1.4.1.4756.20.730.20.1.50 | Columnf2000EASIPInterface3IPV6CurrentLeaseLocal | read-only | current | f2000EAS Series card IP Interfaces: IPV6 Current lease Address |
| 1.3.6.1.4.1.4756.20.730.20.1.51 | Columnf2000EASIPInterface3IPV6AddressLocal | read-only | current | f2000EAS Series card IP Interfaces3: IPV6 Address |
| 1.3.6.1.4.1.4756.20.730.20.1.52 | Columnf2000EASIPInterface3IPV6MASKLenLocal | read-only | current | f2000EAS Series card IP Interfaces: IPV6 MASK Length |
| 1.3.6.1.4.1.4756.20.730.20.1.53 | Columnf2000EASIPInterface4IPV6DHCPLocal | read-write | current | f2000EAS Series card IP Interfaces4: IPV6 DHCP |
| 1.3.6.1.4.1.4756.20.730.20.1.54 | Columnf2000EASIPInterface4IPV6RapidCommitLocal | read-write | current | f2000EAS Series card IP Interfaces4: IPV6 RapidCommit |
| 1.3.6.1.4.1.4756.20.730.20.1.55 | Columnf2000EASIPInterface4IPV6CurrentLeaseLocal | read-only | current | f2000EAS Series card IP Interfaces: IPV6 Current lease Address |
| 1.3.6.1.4.1.4756.20.730.20.1.56 | Columnf2000EASIPInterface4IPV6AddressLocal | read-only | current | f2000EAS Series card IP Interfaces: IPV6 Address |
| 1.3.6.1.4.1.4756.20.730.20.1.57 | Columnf2000EASIPInterface4IPV6MASKLenLocal | read-only | current | f2000EAS Series card IP Interfaces: IPV6 MASK Length |
| 1.3.6.1.4.1.4756.20.730.20.1.58 | Columnf2000EASIPRoutes1NetworkLocal | read-only | current | f2000EAS Series card IP Routes: NetWork |
| 1.3.6.1.4.1.4756.20.730.20.1.59 | Columnf2000EASIPRoutes1MASKLenLocal | read-only | current | f2000EAS Series card IP Routes: MASK Length |
| 1.3.6.1.4.1.4756.20.730.20.1.60 | Columnf2000EASIPRoutes1GetwayLocal | read-only | current | f2000EAS Series card IP Routes: Getway |
| 1.3.6.1.4.1.4756.20.730.20.1.61 | Columnf2000EASIPRoutes1HopVLANLocal | read-only | current | f2000EAS Series card IP Routes: The VLAN associated with the IP Routes. Only ports in this VLAN will be able to access the IP Routes. |
| 1.3.6.1.4.1.4756.20.730.20.1.62 | Columnf2000EASIPRoutes2NetworkLocal | read-only | current | f2000EAS Series card IP Routes: NetWork |
| 1.3.6.1.4.1.4756.20.730.20.1.63 | Columnf2000EASIPRoutes2MASKLenLocal | read-only | current | f2000EAS Series card IP Routes: MASK Length |
| 1.3.6.1.4.1.4756.20.730.20.1.64 | Columnf2000EASIPRoutes2GetwayLocal | read-only | current | f2000EAS Series card IP Routes: Getway |
| 1.3.6.1.4.1.4756.20.730.20.1.65 | Columnf2000EASIPRoutes2HopVLANLocal | read-only | current | f2000EAS Series card IP Routes: The VLAN associated with the IP Routes. Only ports in this VLAN will be able to access the IP Routes. |
| 1.3.6.1.4.1.4756.20.730.20.1.66 | Columnf2000EASIPRoutes3NetworkLocal | read-only | current | f2000EAS Series card IP Routes: NetWork |
| 1.3.6.1.4.1.4756.20.730.20.1.67 | Columnf2000EASIPRoutes3MASKLenLocal | read-only | current | f2000EAS Series card IP Routes: MASK Length |
| 1.3.6.1.4.1.4756.20.730.20.1.68 | Columnf2000EASIPRoutes3GetwayLocal | read-only | current | f2000EAS Series card IP Routes: Getway |
| 1.3.6.1.4.1.4756.20.730.20.1.69 | Columnf2000EASIPRoutes3HopVLANLocal | read-only | current | f2000EAS Series card IP Routes: The VLAN associated with the IP Routes. Only ports in this VLAN will be able to access the IP Routes. |
| 1.3.6.1.4.1.4756.20.730.20.1.70 | Columnf2000EASIPRoutes4NetworkLocal | read-only | current | f2000EAS Series card IP Routes: NetWork |
| 1.3.6.1.4.1.4756.20.730.20.1.71 | Columnf2000EASIPRoutes4MASKLenLocal | read-only | current | f2000EAS Series card IP Routes: MASK Length |
| 1.3.6.1.4.1.4756.20.730.20.1.72 | Columnf2000EASIPRoutes4GetwayLocal | read-only | current | f2000EAS Series card IP Routes: Getway |
| 1.3.6.1.4.1.4756.20.730.20.1.73 | Columnf2000EASIPRoutes4HopVLANLocal | read-only | current | f2000EAS Series card IP Routes: The VLAN associated with the IP Routes. Only ports in this VLAN will be able to access the IP Routes. |
| 1.3.6.1.4.1.4756.20.730.20.1.74 | Columnf2000EASPort1LinkstsLocal | read-only | current | f2000EAS Series card Port1 link status: 0:Link down 1:Link up |
| 1.3.6.1.4.1.4756.20.730.20.1.75 | Columnf2000EASPort1SpeedstsLocal | read-only | current | f2000EAS Series card Port1 speed status |
| 1.3.6.1.4.1.4756.20.730.20.1.76 | Columnf2000EASPort1DuplexstsLocal | read-only | current | f2000EAS Series card Port1 duplex status 0: Half 1: Full |
| 1.3.6.1.4.1.4756.20.730.20.1.77 | Columnf2000EASPort1RxPausestsLocal | read-only | current | f2000EAS Series card Port1 rx pause status 0: No 1: Yes |
| 1.3.6.1.4.1.4756.20.730.20.1.78 | Columnf2000EASPort1TxPausestsLocal | read-only | current | f2000EAS Series card Port1 tx pause status 0: No 1: Yes |
| 1.3.6.1.4.1.4756.20.730.20.1.79 | Columnf2000EASPort2LinkstsLocal | read-only | current | f2000EAS Series card Port2 link status: 0:Link down 1:Link up |
| 1.3.6.1.4.1.4756.20.730.20.1.80 | Columnf2000EASPort2SpeedstsLocal | read-only | current | f2000EAS Series card Port2 speed status |
| 1.3.6.1.4.1.4756.20.730.20.1.81 | Columnf2000EASPort2DuplexstsLocal | read-only | current | f2000EAS Series card Port2 duplex status 0: Half 1: Full |
| 1.3.6.1.4.1.4756.20.730.20.1.82 | Columnf2000EASPort2RxPausestsLocal | read-only | current | f2000EAS Series card Port2 rx pause status 0: No 1: Yes |
| 1.3.6.1.4.1.4756.20.730.20.1.83 | Columnf2000EASPort2TxPausestsLocal | read-only | current | f2000EAS Series card Port2 tx pause status 0: No 1: Yes |
| 1.3.6.1.4.1.4756.20.730.20.1.84 | Columnf2000EASPort3LinkstsLocal | read-only | current | f2000EAS Series card Port3 link status: 0:Link down 1:Link up |
| 1.3.6.1.4.1.4756.20.730.20.1.85 | Columnf2000EASPort3SpeedstsLocal | read-only | current | f2000EAS Series card Port3 speed status |
| 1.3.6.1.4.1.4756.20.730.20.1.86 | Columnf2000EASPort3DuplexstsLocal | read-only | current | f2000EAS Series card Port3 duplex status 0: Half 1: Full |
| 1.3.6.1.4.1.4756.20.730.20.1.87 | Columnf2000EASPort3RxPausestsLocal | read-only | current | f2000EAS Series card Port3 rx pause status 0: No 1: Yes |
| 1.3.6.1.4.1.4756.20.730.20.1.88 | Columnf2000EASPort3TxPausestsLocal | read-only | current | f2000EAS Series card Port3 tx pause status 0: No 1: Yes |
| 1.3.6.1.4.1.4756.20.730.20.1.89 | Columnf2000EASPort4LinkstsLocal | read-only | current | f2000EAS Series card Port4 link status: 0:Link down 1:Link up |
| 1.3.6.1.4.1.4756.20.730.20.1.90 | Columnf2000EASPort4SpeedstsLocal | read-only | current | f2000EAS Series card Port4 speed status |
| 1.3.6.1.4.1.4756.20.730.20.1.91 | Columnf2000EASPort4DuplexstsLocal | read-only | current | f2000EAS Series card Port4 duplex status 0: Half 1: Full |
| 1.3.6.1.4.1.4756.20.730.20.1.92 | Columnf2000EASPort4RxPausestsLocal | read-only | current | f2000EAS Series card Port4 rx pause status 0: No 1: Yes |
| 1.3.6.1.4.1.4756.20.730.20.1.93 | Columnf2000EASPort4TxPausestsLocal | read-only | current | f2000EAS Series card Port4 tx pause status 0: No 1: Yes |
| 1.3.6.1.4.1.4756.20.730.20.1.94 | Columnf2000EASPort1SpeedConfLocal | read-write | current | f2000EAS Series card Port1 speed config 0: disable 1: auto 2: 100M FDX 3: 1G FDX |
| 1.3.6.1.4.1.4756.20.730.20.1.95 | Columnf2000EASPort1flowConrolLocal | read-write | current | f2000EAS Series card Port1 flow control config 0: no 1: yes |
| 1.3.6.1.4.1.4756.20.730.20.1.96 | Columnf2000EASPort1MaxFrameLocal | read-write | current | f2000EAS Series card Port1 max frame config |
| 1.3.6.1.4.1.4756.20.730.20.1.97 | Columnf2000EASPort1ALSLocal | read-write | current | f2000EAS Series card Port1 auto laser shutdown: 0: Disable 1: Enable |
| 1.3.6.1.4.1.4756.20.730.20.1.98 | Columnf2000EASPort1FrameLengthCheckLocal | read-write | current | f2000EAS Series card Port1 Frame Length Check config 0: no 1: yes |
| 1.3.6.1.4.1.4756.20.730.20.1.99 | Columnf2000EASPort2SpeedConfLocal | read-write | current | f2000EAS Series card Port2 speed config 0: disable 1: auto 2: 100M FDX 3: 1G FDX |
| 1.3.6.1.4.1.4756.20.730.20.1.100 | Columnf2000EASPort2flowConrolLocal | read-write | current | f2000EAS Series card Port2 flow control config 0: no 1: yes |
| 1.3.6.1.4.1.4756.20.730.20.1.101 | Columnf2000EASPort2MaxFrameLocal | read-write | current | f2000EAS Series card Port2 max frame config |
| 1.3.6.1.4.1.4756.20.730.20.1.102 | Columnf2000EASPort2ALSLocal | read-write | current | f2000EAS Series card Port2 auto laser shutdown: 0: Disable 1: Enable |
| 1.3.6.1.4.1.4756.20.730.20.1.103 | Columnf2000EASPort2FrameLengthCheckLocal | read-write | current | f2000EAS Series card Port2 Frame Length Check config 0: no 1: yes |
| 1.3.6.1.4.1.4756.20.730.20.1.104 | Columnf2000EASPort3SpeedConfLocal | read-write | current | f2000EAS Series card Port3 speed config 0: disable 1: auto 2: 10M HDX 3: 10M FDX 4: 100M HDX 5: 100M FDX 6: 1G FDX |
| 1.3.6.1.4.1.4756.20.730.20.1.105 | Columnf2000EASPort3flowConrolLocal | read-write | current | f2000EAS Series card Port3 flow control config 0: no 1: yes |
| 1.3.6.1.4.1.4756.20.730.20.1.106 | Columnf2000EASPort3MaxFrameLocal | read-write | current | f2000EAS Series card Port3 max frame config |
| 1.3.6.1.4.1.4756.20.730.20.1.107 | Columnf2000EASPort3CollisionModeLocal | read-write | current | f2000EAS Series card Port3 collision mode config. 0: Discard 1: Restart |
| 1.3.6.1.4.1.4756.20.730.20.1.108 | Columnf2000EASPort3ALSLocal | read-write | current | f2000EAS Series card Port3 auto laser shutdown 0: Disable 1: Enable |
| 1.3.6.1.4.1.4756.20.730.20.1.109 | Columnf2000EASPort3FrameLengthCheckLocal | read-write | current | f2000EAS Series card Port3 Frame Length Check config 0: no 1: yes |
| 1.3.6.1.4.1.4756.20.730.20.1.110 | Columnf2000EASPort4SpeedConfLocal | read-write | current | f2000EAS Series card Port4 speed config 0: disable 1: auto 2: 10M HDX 3: 10M FDX 4: 100M HDX 5: 100M FDX 6: 1G FDX |
| 1.3.6.1.4.1.4756.20.730.20.1.111 | Columnf2000EASPort4flowConrolLocal | read-write | current | f2000EAS Series card Port4 flow control config 0: no 1: yes |
| 1.3.6.1.4.1.4756.20.730.20.1.112 | Columnf2000EASPort4MaxFrameLocal | read-write | current | f2000EAS Series card Port4 max frame config |
| 1.3.6.1.4.1.4756.20.730.20.1.113 | Columnf2000EASPort4CollisionModeLocal | read-write | current | f2000EAS Series card Port4 collision mode config 0: Discard 1: Restart |
| 1.3.6.1.4.1.4756.20.730.20.1.114 | Columnf2000EASPort4ALSLocal | read-write | current | f2000EAS Series card Port4 auto laser shutdown 0: Disable 1: Enable |
| 1.3.6.1.4.1.4756.20.730.20.1.115 | Columnf2000EASPort4FrameLengthCheckLocal | read-write | current | f2000EAS Series card Port4 Frame Length Check config 0: no 1: yes |
| 1.3.6.1.4.1.4756.20.730.20.1.116 | Columnf2000EASPort1AdvDuplexHdxLocal | read-write | current | f2000EAS Series card Port1 Adv Dpulex Hdx 0: OFF 1: ON |
| 1.3.6.1.4.1.4756.20.730.20.1.117 | Columnf2000EASPort1AdvDuplexFdxLocal | read-write | current | f2000EAS Series card Port1 Adv Dpulex Fdx 0: OFF 1: ON |
| 1.3.6.1.4.1.4756.20.730.20.1.118 | Columnf2000EASPort1AdvSpeed10MLocal | read-write | current | f2000EAS Series card Port1 Adv Speed 10M 0: OFF 1: ON |
| 1.3.6.1.4.1.4756.20.730.20.1.119 | Columnf2000EASPort1AdvSpeed100MLocal | read-write | current | f2000EAS Series card Port1 Adv Speed 100M 0: OFF 1: ON |
| 1.3.6.1.4.1.4756.20.730.20.1.120 | Columnf2000EASPort1AdvSpeed1GLocal | read-write | current | f2000EAS Series card Port1 Adv Speed 1G 0: OFF 1: ON |
| 1.3.6.1.4.1.4756.20.730.20.1.121 | Columnf2000EASPort2AdvDuplexHdxLocal | read-write | current | f2000EAS Series card Port2 Adv Dpulex Hdx 0: OFF 1: ON |
| 1.3.6.1.4.1.4756.20.730.20.1.122 | Columnf2000EASPort2AdvDuplexFdxLocal | read-write | current | f2000EAS Series card Port2 Adv Dpulex Fdx 0: OFF 1: ON |
| 1.3.6.1.4.1.4756.20.730.20.1.123 | Columnf2000EASPort2AdvSpeed10MLocal | read-write | current | f2000EAS Series card Port2 Adv Speed 10M 0: OFF 1: ON |
| 1.3.6.1.4.1.4756.20.730.20.1.124 | Columnf2000EASPort2AdvSpeed100MLocal | read-write | current | f2000EAS Series card Port2 Adv Speed 100M 0: OFF 1: ON |
| 1.3.6.1.4.1.4756.20.730.20.1.125 | Columnf2000EASPort2AdvSpeed1GLocal | read-write | current | f2000EAS Series card Port2 Adv Speed 1G 0: OFF 1: ON |
| 1.3.6.1.4.1.4756.20.730.20.1.126 | Columnf2000EASPort3AdvDuplexHdxLocal | read-write | current | f2000EAS Series card Port3 Adv Dpulex Hdx 0: OFF 1: ON |
| 1.3.6.1.4.1.4756.20.730.20.1.127 | Columnf2000EASPort3AdvDuplexFdxLocal | read-write | current | f2000EAS Series card Port3 Adv Dpulex Fdx 0: OFF 1: ON |
| 1.3.6.1.4.1.4756.20.730.20.1.128 | Columnf2000EASPort3AdvSpeed10MLocal | read-write | current | f2000EAS Series card Port3 Adv Speed 10M 0: OFF 1: ON |
| 1.3.6.1.4.1.4756.20.730.20.1.129 | Columnf2000EASPort3AdvSpeed100MLocal | read-write | current | f2000EAS Series card Port3 Adv Speed 100M 0: OFF 1: ON |
| 1.3.6.1.4.1.4756.20.730.20.1.130 | Columnf2000EASPort3AdvSpeed1GLocal | read-write | current | f2000EAS Series card Port3 Adv Speed 1G 0: OFF 1: ON |
| 1.3.6.1.4.1.4756.20.730.20.1.131 | Columnf2000EASPort4AdvDuplexHdxLocal | read-write | current | f2000EAS Series card Port4 Adv Dpulex Hdx 0: OFF 1: ON |
| 1.3.6.1.4.1.4756.20.730.20.1.132 | Columnf2000EASPort4AdvDuplexFdxLocal | read-write | current | f2000EAS Series card Port4 Adv Dpulex Fdx 0: OFF 1: ON |
| 1.3.6.1.4.1.4756.20.730.20.1.133 | Columnf2000EASPort4AdvSpeed10MLocal | read-write | current | f2000EAS Series card Port4 Adv Speed 10M 0: OFF 1: ON |
| 1.3.6.1.4.1.4756.20.730.20.1.134 | Columnf2000EASPort4AdvSpeed100MLocal | read-write | current | f2000EAS Series card Port4 Adv Speed 100M 0: OFF 1: ON |
| 1.3.6.1.4.1.4756.20.730.20.1.135 | Columnf2000EASPort4AdvSpeed1GLocal | read-write | current | f2000EAS Series card Port4 Adv Speed 1G 0: OFF 1: ON |
| 1.3.6.1.4.1.4756.20.730.20.1.136 | Columnf2000EASPortResetLocal | read-write | current | f2000EAS Series card port reset 0: OFF 1: Action |
| 1.3.6.1.4.1.4756.20.730.20.1.137 | Columnf2000EASSetDefaultLocal | read-write | current | f2000EAS Series card set to default config 0: OFF 1: Action |
| 1.3.6.1.4.1.4756.20.730.20.1.138 | Columnf2000EASPort1PacketsRxLocal | read-only | current | f2000EAS Series card port1 traffic overview:: Packets Rx |
| 1.3.6.1.4.1.4756.20.730.20.1.139 | Columnf2000EASPort1PacketsTxLocal | read-only | current | f2000EAS Series card port1 traffic overview:: Packets Tx |
| 1.3.6.1.4.1.4756.20.730.20.1.140 | Columnf2000EASPort1BytesRxLocal | read-only | current | f2000EAS Series card port1 traffic overview:: Bytes Rx |
| 1.3.6.1.4.1.4756.20.730.20.1.141 | Columnf2000EASPort1BytesTxLocal | read-only | current | f2000EAS Series card port1 traffic overview:: Bytes Tx |
| 1.3.6.1.4.1.4756.20.730.20.1.142 | Columnf2000EASPort1ErrorsRxLocal | read-only | current | f2000EAS Series card port1 traffic overview:: Errors Rx |
| 1.3.6.1.4.1.4756.20.730.20.1.143 | Columnf2000EASPort1ErrorsTxLocal | read-only | current | f2000EAS Series card port1 traffic overview:: Errors Tx |
| 1.3.6.1.4.1.4756.20.730.20.1.144 | Columnf2000EASPort1DropsRxLocal | read-only | current | f2000EAS Series card port1 traffic overview:: Drops Rx |
| 1.3.6.1.4.1.4756.20.730.20.1.145 | Columnf2000EASPort1DropsTxLocal | read-only | current | f2000EAS Series card port1 traffic overview:: Drops Tx |
| 1.3.6.1.4.1.4756.20.730.20.1.146 | Columnf2000EASPort1FilteredRxLocal | read-only | current | f2000EAS Series card port1 traffic overview:: Filtered Rx |
| 1.3.6.1.4.1.4756.20.730.20.1.147 | Columnf2000EASPort2PacketsRxLocal | read-only | current | f2000EAS Series card port2 traffic overview:: Packets Rx |
| 1.3.6.1.4.1.4756.20.730.20.1.148 | Columnf2000EASPort2PacketsTxLocal | read-only | current | f2000EAS Series card port2 traffic overview:: Packets Tx |
| 1.3.6.1.4.1.4756.20.730.20.1.149 | Columnf2000EASPort2BytesRxLocal | read-only | current | f2000EAS Series card port2 traffic overview:: Bytes Rx |
| 1.3.6.1.4.1.4756.20.730.20.1.150 | Columnf2000EASPort2BytesTxLocal | read-only | current | f2000EAS Series card port2 traffic overview:: Bytes Tx |
| 1.3.6.1.4.1.4756.20.730.20.1.151 | Columnf2000EASPort2ErrorsRxLocal | read-only | current | f2000EAS Series card port2 traffic overview:: Errors Rx |
| 1.3.6.1.4.1.4756.20.730.20.1.152 | Columnf2000EASPort2ErrorsTxLocal | read-only | current | f2000EAS Series card port2 traffic overview:: Errors Tx |
| 1.3.6.1.4.1.4756.20.730.20.1.153 | Columnf2000EASPort2DropsRxLocal | read-only | current | f2000EAS Series card port2 traffic overview:: Drops Rx |
| 1.3.6.1.4.1.4756.20.730.20.1.154 | Columnf2000EASPort2DropsTxLocal | read-only | current | f2000EAS Series card port2 traffic overview:: Drops Tx |
| 1.3.6.1.4.1.4756.20.730.20.1.155 | Columnf2000EASPort2FilteredRxLocal | read-only | current | f2000EAS Series card port2 traffic overview:: Filtered Rx |
| 1.3.6.1.4.1.4756.20.730.20.1.156 | Columnf2000EASPort3PacketsRxLocal | read-only | current | f2000EAS Series card port3 traffic overview:: Packets Rx |
| 1.3.6.1.4.1.4756.20.730.20.1.157 | Columnf2000EASPort3PacketsTxLocal | read-only | current | f2000EAS Series card port3 traffic overview:: Packets Tx |
| 1.3.6.1.4.1.4756.20.730.20.1.158 | Columnf2000EASPort3BytesRxLocal | read-only | current | f2000EAS Series card port3 traffic overview:: Bytes Rx |
| 1.3.6.1.4.1.4756.20.730.20.1.159 | Columnf2000EASPort3BytesTxLocal | read-only | current | f2000EAS Series card port3 traffic overview:: Bytes Tx |
| 1.3.6.1.4.1.4756.20.730.20.1.160 | Columnf2000EASPort3ErrorsRxLocal | read-only | current | f2000EAS Series card port3 traffic overview:: Errors Rx |
| 1.3.6.1.4.1.4756.20.730.20.1.161 | Columnf2000EASPort3ErrorsTxLocal | read-only | current | f2000EAS Series card port3 traffic overview:: Errors Tx |
| 1.3.6.1.4.1.4756.20.730.20.1.162 | Columnf2000EASPort3DropsRxLocal | read-only | current | f2000EAS Series card port3 traffic overview:: Drops Rx |
| 1.3.6.1.4.1.4756.20.730.20.1.163 | Columnf2000EASPort3DropsTxLocal | read-only | current | f2000EAS Series card port3 traffic overview:: Drops Tx |
| 1.3.6.1.4.1.4756.20.730.20.1.164 | Columnf2000EASPort3FilteredRxLocal | read-only | current | f2000EAS Series card port3 traffic overview:: Filtered Rx |
| 1.3.6.1.4.1.4756.20.730.20.1.165 | Columnf2000EASPort4PacketsRxLocal | read-only | current | f2000EAS Series card port4 traffic overview:: Packets Rx |
| 1.3.6.1.4.1.4756.20.730.20.1.166 | Columnf2000EASPort4PacketsTxLocal | read-only | current | f2000EAS Series card port4 traffic overview:: Packets Tx |
| 1.3.6.1.4.1.4756.20.730.20.1.167 | Columnf2000EASPort4BytesRxLocal | read-only | current | f2000EAS Series card port4 traffic overview:: Bytes Rx |
| 1.3.6.1.4.1.4756.20.730.20.1.168 | Columnf2000EASPort4BytesTxLocal | read-only | current | f2000EAS Series card port4 traffic overview:: Bytes Tx |
| 1.3.6.1.4.1.4756.20.730.20.1.169 | Columnf2000EASPort4ErrorsRxLocal | read-only | current | f2000EAS Series card port4 traffic overview:: Errors Rx |
| 1.3.6.1.4.1.4756.20.730.20.1.170 | Columnf2000EASPort4ErrorsTxLocal | read-only | current | f2000EAS Series card port4 traffic overview:: Errors Tx |
| 1.3.6.1.4.1.4756.20.730.20.1.171 | Columnf2000EASPort4DropsRxLocal | read-only | current | f2000EAS Series card port4 traffic overview:: Drops Rx |
| 1.3.6.1.4.1.4756.20.730.20.1.172 | Columnf2000EASPort4DropsTxLocal | read-only | current | f2000EAS Series card port4 traffic overview:: Drops Tx |
| 1.3.6.1.4.1.4756.20.730.20.1.173 | Columnf2000EASPort4FilteredRxLocal | read-only | current | f2000EAS Series card port4 traffic overview:: Filtered Rx |
| 1.3.6.1.4.1.4756.20.730.20.1.174 | Columnf2000EASDeviceActiveLocal | read-only | current | f2000EAS Series card device active 0: Disable 1: Enable |
| 1.3.6.1.4.1.4756.20.730.20.1.175 | Columnf2000EASFx1DDLocal | read-only | current | f2000EAS Series card fiber1 port Digital Diagnostic function: 0:No 1:Yes |
| 1.3.6.1.4.1.4756.20.730.20.1.176 | Columnf2000EASFx1DDVendorLocal | read-only | current | f2000EAS Series card fiber1 port D/D information: Vendor name |
| 1.3.6.1.4.1.4756.20.730.20.1.177 | Columnf2000EASFx1DDPartNoLocal | read-only | current | f2000EAS Series card fiber1 port D/D information: Vendor part number |
| 1.3.6.1.4.1.4756.20.730.20.1.178 | Columnf2000EASFx1DDFiberTypeLocal | read-only | current | f2000EAS Series card fiber1 port D/D information: Fiber Type |
| 1.3.6.1.4.1.4756.20.730.20.1.179 | Columnf2000EASFx1DDWaveLenLocal | read-only | current | f2000EAS Series card fiber1 port D/D information: Wave length |
| 1.3.6.1.4.1.4756.20.730.20.1.180 | Columnf2000EASFx1DDWaveLen2Local | read-only | current | f2000EAS Series card fiber1 port D/D information: Wave length 2 |
| 1.3.6.1.4.1.4756.20.730.20.1.181 | Columnf2000EASFx1DDLinkLenLocal | read-only | current | f2000EAS Series card fiber1 port D/D information: Link length |
| 1.3.6.1.4.1.4756.20.730.20.1.182 | Columnf2000EASFx1DDLenUnitLocal | read-only | current | f2000EAS Series card fiber1 port D/D information: Length Unit |
| 1.3.6.1.4.1.4756.20.730.20.1.183 | Columnf2000EASFx1DDStatusLocal | read-only | current | f2000EAS Series card fiber1 port D/D information: Status Support |
| 1.3.6.1.4.1.4756.20.730.20.1.184 | Columnf2000EASFx1DDRxSensLocal | read-only | current | f2000EAS Series card fiber1 port D/D information: Rx Sensitivity |
| 1.3.6.1.4.1.4756.20.730.20.1.185 | Columnf2000EASFx1DDTxPWRLocal | read-only | current | f2000EAS Series card fiber1 port D/D information: Tx power |
| 1.3.6.1.4.1.4756.20.730.20.1.186 | Columnf2000EASFx1DDRxPWRLocal | read-only | current | f2000EAS Series card fiber1 port D/D information: Rx power |
| 1.3.6.1.4.1.4756.20.730.20.1.187 | Columnf2000EASFx1DDTempLocal | read-only | current | f2000EAS Series card fiber1 port D/D information: Temperature in degree C |
| 1.3.6.1.4.1.4756.20.730.20.1.188 | Columnf2000EASFx1DDPWRMarginLocal | read-only | current | f2000EAS Series card fiber1 port D/D information: Power margin |
| 1.3.6.1.4.1.4756.20.730.20.1.189 | Columnf2000EASFx1DDPWRLossLocal | read-only | current | f2000EAS Series card fiber1 port D/D information: Power loss |
| 1.3.6.1.4.1.4756.20.730.20.1.190 | Columnf2000EASFx2DDLocal | read-only | current | f2000EAS Series card fiber2 Digital Diagnostic function: 0:NO 1:Yes |
| 1.3.6.1.4.1.4756.20.730.20.1.191 | Columnf2000EASFx2DDVendorLocal | read-only | current | f2000EAS Series card fiber2 D/D information: Vendor name |
| 1.3.6.1.4.1.4756.20.730.20.1.192 | Columnf2000EASFx2DDPartNoLocal | read-only | current | f2000EAS Series card fiber2 D/D information: Vendor part number |
| 1.3.6.1.4.1.4756.20.730.20.1.193 | Columnf2000EASFx2DDFiberTypeLocal | read-only | current | f2000EAS Series card fiber2 D/D information: Fiber Type |
| 1.3.6.1.4.1.4756.20.730.20.1.194 | Columnf2000EASFx2DDWaveLenLocal | read-only | current | f2000EAS Series card fiber2 D/D information: Wave length 1 |
| 1.3.6.1.4.1.4756.20.730.20.1.195 | Columnf2000EASFx2DDWaveLen2Local | read-only | current | f2000EAS Series card fiber2 D/D information: Wave length 2 |
| 1.3.6.1.4.1.4756.20.730.20.1.196 | Columnf2000EASFx2DDLinkLenLocal | read-only | current | f2000EAS Series card fiber2 D/D information: Link length |
| 1.3.6.1.4.1.4756.20.730.20.1.197 | Columnf2000EASFx2DDLenUnitLocal | read-only | current | f2000EAS Series card fiber2 D/D information: Length Unit |
| 1.3.6.1.4.1.4756.20.730.20.1.198 | Columnf2000EASFx2DDStatusLocal | read-only | current | f2000EAS Series card fiber2 D/D information: Status Support |
| 1.3.6.1.4.1.4756.20.730.20.1.199 | Columnf2000EASFx2DDRxSensLocal | read-only | current | f2000EAS Series card fiber2 D/D information: Rx Sensitivity |
| 1.3.6.1.4.1.4756.20.730.20.1.200 | Columnf2000EASFx2DDTxPWRLocal | read-only | current | f2000EAS Series card fiber2 D/D information: Tx power |
| 1.3.6.1.4.1.4756.20.730.20.1.201 | Columnf2000EASFx2DDRxPWRLocal | read-only | current | f2000EAS Series card fiber2 D/D information: Rx power |
| 1.3.6.1.4.1.4756.20.730.20.1.202 | Columnf2000EASFx2DDTempLocal | read-only | current | f2000EAS Series card fiber2 D/D information: Temperature in degree C |
| 1.3.6.1.4.1.4756.20.730.20.1.203 | Columnf2000EASFx2DDPWRMarginLocal | read-only | current | f2000EAS Series card fiber2 D/D information: Power margin |
| 1.3.6.1.4.1.4756.20.730.20.1.204 | Columnf2000EASFx2DDPWRLossLocal | read-only | current | f2000EAS Series card fiber2 D/D information: Power loss |
| 1.3.6.1.4.1.4756.20.730.20.1.205 | Columnf2000EASFx3DDLocal | read-only | current | f2000EAS Series card fiber3 Digital Diagnostic function: 0:NO 1:Yes |
| 1.3.6.1.4.1.4756.20.730.20.1.206 | Columnf2000EASFx3DDVendorLocal | read-only | current | f2000EAS Series card fiber3 D/D information: Vendor name |
| 1.3.6.1.4.1.4756.20.730.20.1.207 | Columnf2000EASFx3DDPartNoLocal | read-only | current | f2000EAS Series card fiber32 D/D information: Vendor part number |
| 1.3.6.1.4.1.4756.20.730.20.1.208 | Columnf2000EASFx3DDFiberTypeLocal | read-only | current | f2000EAS Series card fiber3 D/D information: Fiber Type |
| 1.3.6.1.4.1.4756.20.730.20.1.209 | Columnf2000EASFx3DDWaveLenLocal | read-only | current | f2000EAS Series card fiber3 D/D information: Wave length 1 |
| 1.3.6.1.4.1.4756.20.730.20.1.210 | Columnf2000EASFx3DDWaveLen2Local | read-only | current | f2000EAS Series card fiber3 D/D information: Wave length 2 |
| 1.3.6.1.4.1.4756.20.730.20.1.211 | Columnf2000EASFx3DDLinkLenLocal | read-only | current | f2000EAS Series card fiber3 D/D information: Link length |
| 1.3.6.1.4.1.4756.20.730.20.1.212 | Columnf2000EASFx3DDLenUnitLocal | read-only | current | f2000EAS Series card fiber3 D/D information: Length Unit |
| 1.3.6.1.4.1.4756.20.730.20.1.213 | Columnf2000EASFx3DDStatusLocal | read-only | current | f2000EAS Series card fiber3 D/D information: Status Support |
| 1.3.6.1.4.1.4756.20.730.20.1.214 | Columnf2000EASFx3DDRxSensLocal | read-only | current | f2000EAS Series card fiber3 D/D information: Rx Sensitivity |
| 1.3.6.1.4.1.4756.20.730.20.1.215 | Columnf2000EASFx3DDTxPWRLocal | read-only | current | f2000EAS Series card fiber3 D/D information: Tx power |
| 1.3.6.1.4.1.4756.20.730.20.1.216 | Columnf2000EASFx3DDRxPWRLocal | read-only | current | f2000EAS Series card fiber3 D/D information: Rx power |
| 1.3.6.1.4.1.4756.20.730.20.1.217 | Columnf2000EASFx3DDTempLocal | read-only | current | f2000EAS Series card fiber3 D/D information: Temperature in degree C |
| 1.3.6.1.4.1.4756.20.730.20.1.218 | Columnf2000EASFx3DDPWRMarginLocal | read-only | current | f2000EAS Series card fiber3 D/D information: Power margin |
| 1.3.6.1.4.1.4756.20.730.20.1.219 | Columnf2000EASFx3DDPWRLossLocal | read-only | current | f2000EAS Series card fiber3 D/D information: Power loss |
| 1.3.6.1.4.1.4756.20.730.20.1.220 | Columnf2000EASFx4DDLocal | read-only | current | f2000EAS Series card fiber4 Digital Diagnostic function: 0:NO 1:Yes |
| 1.3.6.1.4.1.4756.20.730.20.1.221 | Columnf2000EASFx4DDVendorLocal | read-only | current | f2000EAS Series card fiber4 D/D information: Vendor name |
| 1.3.6.1.4.1.4756.20.730.20.1.222 | Columnf2000EASFx4DDPartNoLocal | read-only | current | f2000EAS Series card fiber4 D/D information: Vendor part number |
| 1.3.6.1.4.1.4756.20.730.20.1.223 | Columnf2000EASFx4DDFiberTypeLocal | read-only | current | f2000EAS Series card fiber4 D/D information: Fiber Type |
| 1.3.6.1.4.1.4756.20.730.20.1.224 | Columnf2000EASFx4DDWaveLenLocal | read-only | current | f2000EAS Series card fiber4 D/D information: Wave length 1 |
| 1.3.6.1.4.1.4756.20.730.20.1.225 | Columnf2000EASFx4DDWaveLen2Local | read-only | current | f2000EAS Series card fiber4 D/D information: Wave length 2 |
| 1.3.6.1.4.1.4756.20.730.20.1.226 | Columnf2000EASFx4DDLinkLenLocal | read-only | current | f2000EAS Series card fiber4 D/D information: Link length |
| 1.3.6.1.4.1.4756.20.730.20.1.227 | Columnf2000EASFx4DDLenUnitLocal | read-only | current | f2000EAS Series card fiber4 D/D information: Length Unit |
| 1.3.6.1.4.1.4756.20.730.20.1.228 | Columnf2000EASFx4DDStatusLocal | read-only | current | f2000EAS Series card fiber4 D/D information: Status Support |
| 1.3.6.1.4.1.4756.20.730.20.1.229 | Columnf2000EASFx4DDRxSensLocal | read-only | current | f2000EAS Series card fiber4 D/D information: Rx Sensitivity |
| 1.3.6.1.4.1.4756.20.730.20.1.230 | Columnf2000EASFx4DDTxPWRLocal | read-only | current | f2000EAS Series card fiber4 D/D information: Tx power |
| 1.3.6.1.4.1.4756.20.730.20.1.231 | Columnf2000EASFx4DDRxPWRLocal | read-only | current | f2000EAS Series card fiber4 D/D information: Rx power |
| 1.3.6.1.4.1.4756.20.730.20.1.232 | Columnf2000EASFx4DDTempLocal | read-only | current | f2000EAS Series card fiber4 D/D information: Temperature in degree C |
| 1.3.6.1.4.1.4756.20.730.20.1.233 | Columnf2000EASFx4DDPWRMarginLocal | read-only | current | f2000EAS Series card fiber4 D/D information: Power margin |
| 1.3.6.1.4.1.4756.20.730.20.1.234 | Columnf2000EASFx4DDPWRLossLocal | read-only | current | f2000EAS Series card fiber4 D/D information: Power loss |
| 1.3.6.1.4.1.4756.20.730.20.1.235 | Columnf2000EASTestLocal | read-only | current | f2000EAS Series card test led sts: 0: Off 1: On |
| 1.3.6.1.4.1.4756.20.730.20.1.236 | Columnf2000EASClearPortCounterLocal | read-write | current | f2000EAS Series card clear port counter: 0: Off 1: Action |
| 1.3.6.1.4.1.4756.20.730.20.1.237 | Columnf2000EASAggrSourceMACAddrLocal | read-write | current | f2000EAS Series card Aggregation Mode Configuration: Source MAC Address 0: No 1: Yes |
| 1.3.6.1.4.1.4756.20.730.20.1.238 | Columnf2000EASAggrDestinationMACAddrLocal | read-write | current | f2000EAS Series card Aggregation Mode Configuration: Destination MAC Address 0: No 1: Yes |
| 1.3.6.1.4.1.4756.20.730.20.1.239 | Columnf2000EASAggrIPAddrLocal | read-write | current | f2000EAS Series card Aggregation Mode Configuration: IP Address 0: No 1: Yes |
| 1.3.6.1.4.1.4756.20.730.20.1.240 | Columnf2000EASAggrTCPUDPPortNumLocal | read-write | current | f2000EAS Series card Aggregation Mode Configuration: TCP/UDP Port Number 0: No 1: Yes |
| 1.3.6.1.4.1.4756.20.730.20.1.241 | Columnf2000EASAggrGroupPort1ConfLocal | read-write | current | f2000EAS Series card Aggregation Group Port1 Configuration: 0: Normal 1: ID1 2: ID2 |
| 1.3.6.1.4.1.4756.20.730.20.1.242 | Columnf2000EASAggrGroupPort2ConfLocal | read-write | current | f2000EAS Series card Aggregation Group Port2 Configuration: 0: Normal 1: ID1 2: ID2 |
| 1.3.6.1.4.1.4756.20.730.20.1.243 | Columnf2000EASAggrGroupPort3ConfLocal | read-write | current | f2000EAS Series card Aggregation Group Port3 Configuration: 0: Normal 1: ID1 2: ID2 |
| 1.3.6.1.4.1.4756.20.730.20.1.244 | Columnf2000EASAggrGroupPort4ConfLocal | read-write | current | f2000EAS Series card Aggregation Group Port4 Configuration: 0: Normal 1: ID1 2: ID2 |
| 1.3.6.1.4.1.4756.20.730.20.1.245 | Columnf2000EASPort1LACPEnabledLocal | read-write | current | f2000EAS Series card Port1 LACP Enabled: 0: No 1: Yes |
| 1.3.6.1.4.1.4756.20.730.20.1.246 | Columnf2000EASPort1LACPKEYLocal | read-write | current | f2000EAS Series card Port1 LACP Key value: The Key value incurred by the port, range 0-65535.The value of 0 means auto. |
| 1.3.6.1.4.1.4756.20.730.20.1.247 | Columnf2000EASPort1LACPRoleLocal | read-write | current | f2000EAS Series card Port1 LACP Role: 0: Passive 1: Active |
| 1.3.6.1.4.1.4756.20.730.20.1.248 | Columnf2000EASPort1LACPTimeOutLocal | read-write | current | f2000EAS Series card Port1 LACP Time out: 0: Slow 1: Fast |
| 1.3.6.1.4.1.4756.20.730.20.1.249 | Columnf2000EASPort1LACPPrioLocal | read-write | current | f2000EAS Series card Port1 LACP priority: The Key value incurred by the port, range 1-65535. |
| 1.3.6.1.4.1.4756.20.730.20.1.250 | Columnf2000EASPort2LACPEnabledLocal | read-write | current | f2000EAS Series card Port2 LACP Enabled: 0: No 1: Yes |
| 1.3.6.1.4.1.4756.20.730.20.1.251 | Columnf2000EASPort2LACPKEYLocal | read-write | current | f2000EAS Series card Port2 LACP Key value: The Key value incurred by the port, range 0-65535.The value of 0 means auto. |
| 1.3.6.1.4.1.4756.20.730.20.1.252 | Columnf2000EASPort2LACPRoleLocal | read-write | current | f2000EAS Series card Port2 LACP Role: 0: Passive 1: Active |
| 1.3.6.1.4.1.4756.20.730.20.1.253 | Columnf2000EASPort2LACPTimeOutLocal | read-write | current | f2000EAS Series card Port2 LACP Time out: 0: Slow 1: Fast |
| 1.3.6.1.4.1.4756.20.730.20.1.254 | Columnf2000EASPort2LACPPrioLocal | read-write | current | f2000EAS Series card Port2 LACP priority: The Key value incurred by the port, range 1-65535. |
| 1.3.6.1.4.1.4756.20.730.20.1.255 | Columnf2000EASPort3LACPEnabledLocal | read-write | current | f2000EAS Series card Port3 LACP Enabled: 0: No 1: Yes |
| 1.3.6.1.4.1.4756.20.730.20.1.256 | Columnf2000EASPort3LACPKEYLocal | read-write | current | f2000EAS Series card Port3 LACP Key value: The Key value incurred by the port, range 0-65535.The value of 0 means auto. |
| 1.3.6.1.4.1.4756.20.730.20.1.257 | Columnf2000EASPort3LACPRoleLocal | read-write | current | f2000EAS Series card Port3 LACP Role: 0: Passive 1: Active |
| 1.3.6.1.4.1.4756.20.730.20.1.258 | Columnf2000EASPort3LACPTimeOutLocal | read-write | current | f2000EAS Series card Port3 LACP Time out: 0: Slow 1: Fast |
| 1.3.6.1.4.1.4756.20.730.20.1.259 | Columnf2000EASPort3LACPPrioLocal | read-write | current | f2000EAS Series card Port3 LACP priority: The Key value incurred by the port, range 1-65535. |
| 1.3.6.1.4.1.4756.20.730.20.1.260 | Columnf2000EASPort4LACPEnabledLocal | read-write | current | f2000EAS Series card Port4 LACP Enabled: 0: No 1: Yes |
| 1.3.6.1.4.1.4756.20.730.20.1.261 | Columnf2000EASPort4LACPKEYLocal | read-write | current | f2000EAS Series card Port4 LACP Key value: The Key value incurred by the port, range 0-65535.The value of 0 means auto. |
| 1.3.6.1.4.1.4756.20.730.20.1.262 | Columnf2000EASPort4LACPRoleLocal | read-write | current | f2000EAS Series card Port4 LACP Role: 0: Passive 1: Active |
| 1.3.6.1.4.1.4756.20.730.20.1.263 | Columnf2000EASPort4LACPTimeOutLocal | read-write | current | f2000EAS Series card Port4 LACP Time out: 0: Slow 1: Fast |
| 1.3.6.1.4.1.4756.20.730.20.1.264 | Columnf2000EASPort4LACPPrioLocal | read-write | current | f2000EAS Series card Port4 LACP priority: The Key value incurred by the port, range 1-65535. |
| 1.3.6.1.4.1.4756.20.730.20.1.265 | Columnf2000EASPort1LACPstsLocal | read-only | current | f2000EAS Series card Port1 LACP status: 0: No 1: Yes 2: Standby |
| 1.3.6.1.4.1.4756.20.730.20.1.266 | Columnf2000EASPort1LACPKEYstsLocal | read-only | current | f2000EAS Series card Port1 LACP status: Key |
| 1.3.6.1.4.1.4756.20.730.20.1.267 | Columnf2000EASPort1LACPAggrIDstsLocal | read-only | current | f2000EAS Series card Port1 LACP status: Aggr ID |
| 1.3.6.1.4.1.4756.20.730.20.1.268 | Columnf2000EASPort1LACPParnterSysIDstsLocal | read-only | current | f2000EAS Series card Port1 LACP status: Parnter System ID |
| 1.3.6.1.4.1.4756.20.730.20.1.269 | Columnf2000EASPort1LACPParnterPortstsLocal | read-only | current | f2000EAS Series card Port1 LACP status: Parnter Port Status |
| 1.3.6.1.4.1.4756.20.730.20.1.270 | Columnf2000EASPort1LACPParnterProistsLocal | read-only | current | f2000EAS Series card Port1 LACP status: Parnter Priority |
| 1.3.6.1.4.1.4756.20.730.20.1.271 | Columnf2000EASPort2LACPstsLocal | read-only | current | f2000EAS Series card Port2 LACP status: 0: No 1: Yes 2: Standby |
| 1.3.6.1.4.1.4756.20.730.20.1.272 | Columnf2000EASPort2LACPKEYstsLocal | read-only | current | f2000EAS Series card Port2 LACP status: Key |
| 1.3.6.1.4.1.4756.20.730.20.1.273 | Columnf2000EASPort2LACPAggrIDstsLocal | read-only | current | f2000EAS Series card Port2 LACP status: Aggr ID |
| 1.3.6.1.4.1.4756.20.730.20.1.274 | Columnf2000EASPort2LACPParnterSysIDstsLocal | read-only | current | f2000EAS Series card Port2 LACP status: Parnter System ID |
| 1.3.6.1.4.1.4756.20.730.20.1.275 | Columnf2000EASPort2LACPParnterPortstsLocal | read-only | current | f2000EAS Series card Port2 LACP status: Parnter Port Status |
| 1.3.6.1.4.1.4756.20.730.20.1.276 | Columnf2000EASPort2LACPParnterProistsLocal | read-only | current | f2000EAS Series card Port2 LACP status: Parnter Priority |
| 1.3.6.1.4.1.4756.20.730.20.1.277 | Columnf2000EASPort3LACPstsLocal | read-only | current | f2000EAS Series card Port3 LACP status: 0: No 1: Yes 2: Standby |
| 1.3.6.1.4.1.4756.20.730.20.1.278 | Columnf2000EASPort3LACPKEYstsLocal | read-only | current | f2000EAS Series card Port3 LACP status: Key |
| 1.3.6.1.4.1.4756.20.730.20.1.279 | Columnf2000EASPort3LACPAggrIDstsLocal | read-only | current | f2000EAS Series card Port3 LACP status: Aggr ID |
| 1.3.6.1.4.1.4756.20.730.20.1.280 | Columnf2000EASPort3LACPParnterSysIDstsLocal | read-only | current | f2000EAS Series card Port3 LACP status: Parnter System ID |
| 1.3.6.1.4.1.4756.20.730.20.1.281 | Columnf2000EASPort3LACPParnterPortstsLocal | read-only | current | f2000EAS Series card Port3 LACP status: Parnter Port Status |
| 1.3.6.1.4.1.4756.20.730.20.1.282 | Columnf2000EASPort3LACPParnterProistsLocal | read-only | current | f2000EAS Series card Port3 LACP status: Parnter Priority |
| 1.3.6.1.4.1.4756.20.730.20.1.283 | Columnf2000EASPort4LACPstsLocal | read-only | current | f2000EAS Series card Port4 LACP status: 0: No 1: Yes 2: Standby |
| 1.3.6.1.4.1.4756.20.730.20.1.284 | Columnf2000EASPort4LACPKEYstsLocal | read-only | current | f2000EAS Series card Port4 LACP status: Key |
| 1.3.6.1.4.1.4756.20.730.20.1.285 | Columnf2000EASPort4LACPAggrIDstsLocal | read-only | current | f2000EAS Series card Port4 LACP status: Aggr ID |
| 1.3.6.1.4.1.4756.20.730.20.1.286 | Columnf2000EASPort4LACPParnterSysIDstsLocal | read-only | current | f2000EAS Series card Port4 LACP status: Parnter System ID |
| 1.3.6.1.4.1.4756.20.730.20.1.287 | Columnf2000EASPort4LACPParnterPortstsLocal | read-only | current | f2000EAS Series card Port4 LACP status: Parnter Port Status |
| 1.3.6.1.4.1.4756.20.730.20.1.288 | Columnf2000EASPort4LACPParnterProistsLocal | read-only | current | f2000EAS Series card Port4 LACP status: Parnter Priority |
| 1.3.6.1.4.1.4756.20.730.20.1.289 | Columnf2000EASOAMPort1EnableLocal | read-write | current | f2000EAS Series card Port1 OAM: 0: Off 1: On |
| 1.3.6.1.4.1.4756.20.730.20.1.290 | Columnf2000EASOAMPort1ModeLocal | read-write | current | f2000EAS Series card Port1 OAM: 0: Passive 1: Active |
| 1.3.6.1.4.1.4756.20.730.20.1.291 | Columnf2000EASOAMPort1LoopBackLocal | read-write | current | f2000EAS Series card Port1 OAM LoopBack: 0: Off 1: On |
| 1.3.6.1.4.1.4756.20.730.20.1.292 | Columnf2000EASOAMPort1LinkMonitorLocal | read-write | current | f2000EAS Series card Port1 OAM Link Monitor: 0: Off 1: On |
| 1.3.6.1.4.1.4756.20.730.20.1.293 | Columnf2000EASOAMPort1MIBRetrievalLocal | read-write | current | f2000EAS Series card Port1 OAM MIB Retrieval: 0: Off 1: On |
| 1.3.6.1.4.1.4756.20.730.20.1.294 | Columnf2000EASOAMPort1LoopBackOPLocal | read-only | current | f2000EAS Series card Port1 OAM LoopBack operation: 0: Off 1: On |
| 1.3.6.1.4.1.4756.20.730.20.1.295 | Columnf2000EASOAMPort2EnableLocal | read-write | current | f2000EAS Series card Port2 OAM: 0: Off 1: On |
| 1.3.6.1.4.1.4756.20.730.20.1.296 | Columnf2000EASOAMPort2ModeLocal | read-write | current | f2000EAS Series card Port2 OAM: 0: Passive 1: Active |
| 1.3.6.1.4.1.4756.20.730.20.1.297 | Columnf2000EASOAMPort2LoopBackLocal | read-write | current | f2000EAS Series card Port2 OAM LoopBack: 0: Off 1: On |
| 1.3.6.1.4.1.4756.20.730.20.1.298 | Columnf2000EASOAMPort2LinkMonitorLocal | read-write | current | f2000EAS Series card Port2 OAM Link Monitor: 0: Off 1: On |
| 1.3.6.1.4.1.4756.20.730.20.1.299 | Columnf2000EASOAMPort2MIBRetrievalLocal | read-write | current | f2000EAS Series card Port2 OAM MIB Retrieval: 0: Off 1: On |
| 1.3.6.1.4.1.4756.20.730.20.1.300 | Columnf2000EASOAMPort2LoopBackOPLocal | read-only | current | f2000EAS Series card Port2 OAM LoopBack operation: 0: Off 1: On |
| 1.3.6.1.4.1.4756.20.730.20.1.301 | Columnf2000EASOAMPort3EnableLocal | read-write | current | f2000EAS Series card Port3 OAM: 0: Off 1: On |
| 1.3.6.1.4.1.4756.20.730.20.1.302 | Columnf2000EASOAMPort3ModeLocal | read-write | current | f2000EAS Series card Port3 OAM: 0: Passive 1: Active |
| 1.3.6.1.4.1.4756.20.730.20.1.303 | Columnf2000EASOAMPort3LoopBackLocal | read-write | current | f2000EAS Series card Port3 OAM: 0: Off 1: On |
| 1.3.6.1.4.1.4756.20.730.20.1.304 | Columnf2000EASOAMPort3LinkMonitorLocal | read-write | current | f2000EAS Series card Port3 OAM Link Monitor: 0: Off 1: On |
| 1.3.6.1.4.1.4756.20.730.20.1.305 | Columnf2000EASOAMPort3MIBRetrievalLocal | read-write | current | f2000EAS Series card Port3 OAM MIB Retrieval: 0: Off 1: On |
| 1.3.6.1.4.1.4756.20.730.20.1.306 | Columnf2000EASOAMPort3LoopBackOPLocal | read-only | current | f2000EAS Series card Port3 OAM LoopBack operation: 0: Disable 1: Enable |
| 1.3.6.1.4.1.4756.20.730.20.1.307 | Columnf2000EASOAMPort4EnableLocal | read-write | current | f2000EAS Series card Port4 OAM: 0: Off 1: On |
| 1.3.6.1.4.1.4756.20.730.20.1.308 | Columnf2000EASOAMPort4ModeLocal | read-write | current | f2000EAS Series card Port4 OAM: 0: Passive 1: Active |
| 1.3.6.1.4.1.4756.20.730.20.1.309 | Columnf2000EASOAMPort4LoopBackLocal | read-write | current | f2000EAS Series card Port4 OAM: 0: Off 1: On |
| 1.3.6.1.4.1.4756.20.730.20.1.310 | Columnf2000EASOAMPort4LinkMonitorLocal | read-write | current | f2000EAS Series card Port4 OAM Link Monitor: 0: Off 1: On |
| 1.3.6.1.4.1.4756.20.730.20.1.311 | Columnf2000EASOAMPort4MIBRetrievalLocal | read-write | current | f2000EAS Series card Port4 OAM MIB Retrieval: 0: Off 1: On |
| 1.3.6.1.4.1.4756.20.730.20.1.312 | Columnf2000EASOAMPort4LoopBackOPLocal | read-only | current | f2000EAS Series card Port4 OAM LoopBack operation: 0: On 1: Off |
| 1.3.6.1.4.1.4756.20.730.20.1.313 | Columnf2000EASPort1EFEErrorWindowLocal | read-write | current | f2000EAS Series card Port1 Link Event Configuration: Error Frame Event - Error Window |
| 1.3.6.1.4.1.4756.20.730.20.1.314 | Columnf2000EASPort1EFEErrorThresholdLocal | read-write | current | f2000EAS Series card Port1 Link Event Configuration: Error Frame Event - Error Threshold |
| 1.3.6.1.4.1.4756.20.730.20.1.315 | Columnf2000EASPort1SPEEErrorWindowLocal | read-write | current | f2000EAS Series card Port1 Link Event Configuration: Symbol Period Error Event - Error Window |
| 1.3.6.1.4.1.4756.20.730.20.1.316 | Columnf2000EASPort1SPEEErrorThresholdLocal | read-write | current | f2000EAS Series card Port1 Link Event Configuration: Symbol Period Error Event - Error Threshold |
| 1.3.6.1.4.1.4756.20.730.20.1.317 | Columnf2000EASPort1SSEErrorWindowLocal | read-write | current | f2000EAS Series card Port1 Link Event Configuration: Seconds Summary Event - Error Window |
| 1.3.6.1.4.1.4756.20.730.20.1.318 | Columnf2000EASPort1SSEErrorThresholdLocal | read-write | current | f2000EAS Series card Port1 Link Event Configuration: Seconds Summary Event - Error Threshold |
| 1.3.6.1.4.1.4756.20.730.20.1.319 | Columnf2000EASPort2EFEErrorWindowLocal | read-write | current | f2000EAS Series card Port2 Link Event Configuration: Error Frame Event - Error Window |
| 1.3.6.1.4.1.4756.20.730.20.1.320 | Columnf2000EASPort2EFEErrorThresholdLocal | read-write | current | f2000EAS Series card Port2 Link Event Configuration: Error Frame Event - Error Threshold |
| 1.3.6.1.4.1.4756.20.730.20.1.321 | Columnf2000EASPort2SPEEErrorWindowLocal | read-write | current | f2000EAS Series card Port2 Link Event Configuration: Symbol Period Error Event - Error Window |
| 1.3.6.1.4.1.4756.20.730.20.1.322 | Columnf2000EASPort2SPEEErrorThresholdLocal | read-write | current | f2000EAS Series card Port2 Link Event Configuration: Symbol Period Error Event - Error Threshold |
| 1.3.6.1.4.1.4756.20.730.20.1.323 | Columnf2000EASPort2SSEErrorWindowLocal | read-write | current | f2000EAS Series card Port2 Link Event Configuration: Seconds Summary Event - Error Window |
| 1.3.6.1.4.1.4756.20.730.20.1.324 | Columnf2000EASPort2SSEErrorThresholdLocal | read-write | current | f2000EAS Series card Port2 Link Event Configuration: Seconds Summary Event - Error Threshold |
| 1.3.6.1.4.1.4756.20.730.20.1.325 | Columnf2000EASPort3EFEErrorWindowLocal | read-write | current | f2000EAS Series card Port3 Link Event Configuration: Error Frame Event - Error Window |
| 1.3.6.1.4.1.4756.20.730.20.1.326 | Columnf2000EASPort3EFEErrorThresholdLocal | read-write | current | f2000EAS Series card Port3 Link Event Configuration: Error Frame Event - Error Threshold |
| 1.3.6.1.4.1.4756.20.730.20.1.327 | Columnf2000EASPort3SPEEErrorWindowLocal | read-write | current | f2000EAS Series card Port3 Link Event Configuration: Symbol Period Error Event - Error Window |
| 1.3.6.1.4.1.4756.20.730.20.1.328 | Columnf2000EASPort3SPEEErrorThresholdLocal | read-write | current | f2000EAS Series card Port3 Link Event Configuration: Symbol Period Error Event - Error Threshold |
| 1.3.6.1.4.1.4756.20.730.20.1.329 | Columnf2000EASPort3SSEErrorWindowLocal | read-write | current | f2000EAS Series card Port3 Link Event Configuration: Seconds Summary Event - Error Window |
| 1.3.6.1.4.1.4756.20.730.20.1.330 | Columnf2000EASPort3SSEErrorThresholdLocal | read-write | current | f2000EAS Series card Port3 Link Event Configuration: Seconds Summary Event - Error Threshold |
| 1.3.6.1.4.1.4756.20.730.20.1.331 | Columnf2000EASPort4EFEErrorWindowLocal | read-write | current | f2000EAS Series card Port4 Link Event Configuration: Error Frame Event - Error Window |
| 1.3.6.1.4.1.4756.20.730.20.1.332 | Columnf2000EASPort4EFEErrorThresholdLocal | read-write | current | f2000EAS Series card Port4 Link Event Configuration: Error Frame Event - Error Threshold |
| 1.3.6.1.4.1.4756.20.730.20.1.333 | Columnf2000EASPort4SPEEErrorWindowLocal | read-write | current | f2000EAS Series card Port4 Link Event Configuration: Symbol Period Error Event - Error Window |
| 1.3.6.1.4.1.4756.20.730.20.1.334 | Columnf2000EASPort4SPEEErrorThresholdLocal | read-write | current | f2000EAS Series card Port4 Link Event Configuration: Symbol Period Error Event - Error Threshold |
| 1.3.6.1.4.1.4756.20.730.20.1.335 | Columnf2000EASPort4SSEErrorWindowLocal | read-write | current | f2000EAS Series card Port4 Link Event Configuration: Seconds Summary Event - Error Window |
| 1.3.6.1.4.1.4756.20.730.20.1.336 | Columnf2000EASPort4SSEErrorThresholdLocal | read-write | current | f2000EAS Series card Port4 Link Event Configuration: Seconds Summary Event - Error Threshold |
| 1.3.6.1.4.1.4756.20.730.20.1.337 | Columnf2000EASPort1RxOAMInfoPDULocal | read-only | current | f2000EAS Series card Port1 Detailed Link OAM Statistics: Rx OAM Information PDU's |
| 1.3.6.1.4.1.4756.20.730.20.1.338 | Columnf2000EASPort1RxUniqueErrorEventLocal | read-only | current | f2000EAS Series card Port1 Detailed Link OAM Statistics: Rx Unique Error Event Notificatio |
| 1.3.6.1.4.1.4756.20.730.20.1.339 | Columnf2000EASPort1RxDuplicateErrorEventLocal | read-only | current | f2000EAS Series card Port1 Detailed Link OAM Statistics: Rx Duplicate Error Event Notification |
| 1.3.6.1.4.1.4756.20.730.20.1.340 | Columnf2000EASPort1RxLoopBackControlLocal | read-only | current | f2000EAS Series card Port1 Detailed Link OAM Statistics: Rx Loopback Control |
| 1.3.6.1.4.1.4756.20.730.20.1.341 | Columnf2000EASPort1RxVariableRequestLocal | read-only | current | f2000EAS Series card Port1 Detailed Link OAM Statistics: Rx Variable Request |
| 1.3.6.1.4.1.4756.20.730.20.1.342 | Columnf2000EASPort1RxVariableResponseLocal | read-only | current | f2000EAS Series card Port1 Detailed Link OAM Statistics: Rx Variable Response |
| 1.3.6.1.4.1.4756.20.730.20.1.343 | Columnf2000EASPort1RxOrgSpecificPDULocal | read-only | current | f2000EAS Series card Port1 Detailed Link OAM Statistics: Rx Org Specific PDU's |
| 1.3.6.1.4.1.4756.20.730.20.1.344 | Columnf2000EASPort1RxUnsupportedCodesLocal | read-only | current | f2000EAS Series card Port1 Detailed Link OAM Statistics: Rx Unsupported Codes |
| 1.3.6.1.4.1.4756.20.730.20.1.345 | Columnf2000EASPort1RxLinkFaultPDULocal | read-only | current | f2000EAS Series card Port1 Detailed Link OAM Statistics: Rx Link Fault PDU's |
| 1.3.6.1.4.1.4756.20.730.20.1.346 | Columnf2000EASPort1RxDyingGaspLocal | read-only | current | f2000EAS Series card Port1 Detailed Link OAM Statistics: Rx Dying Gasp |
| 1.3.6.1.4.1.4756.20.730.20.1.347 | Columnf2000EASPort1RxCriticalEventPDULocal | read-only | current | f2000EAS Series card Port1 Detailed Link OAM Statistics: Rx Dying Gasp |
| 1.3.6.1.4.1.4756.20.730.20.1.348 | Columnf2000EASPort1TxOAMInfoPDULocal | read-only | current | f2000EAS Series card Port1 Detailed Link OAM Statistics: Tx OAM Information PDU's |
| 1.3.6.1.4.1.4756.20.730.20.1.349 | Columnf2000EASPort1TxUniqueErrorEventLocal | read-only | current | f2000EAS Series card Port1 Detailed Link OAM Statistics: Tx Unique Error Event Notificatio |
| 1.3.6.1.4.1.4756.20.730.20.1.350 | Columnf2000EASPort1TxDuplicateErrorEventLocal | read-only | current | f2000EAS Series card Port1 Detailed Link OAM Statistics: Tx Duplicate Error Event Notification |
| 1.3.6.1.4.1.4756.20.730.20.1.351 | Columnf2000EASPort1TxLoopBackControlLocal | read-only | current | f2000EAS Series card Port1 Detailed Link OAM Statistics: Tx Loopback Control |
| 1.3.6.1.4.1.4756.20.730.20.1.352 | Columnf2000EASPort1TxVariableRequestLocal | read-only | current | f2000EAS Series card Port1 Detailed Link OAM Statistics: Tx Variable Request |
| 1.3.6.1.4.1.4756.20.730.20.1.353 | Columnf2000EASPort1TxVariableResponseLocal | read-only | current | f2000EAS Series card Port1 Detailed Link OAM Statistics: Tx Variable Response |
| 1.3.6.1.4.1.4756.20.730.20.1.354 | Columnf2000EASPort1TxOrgSpecificPDULocal | read-only | current | f2000EAS Series card Port1 Detailed Link OAM Statistics: Tx Org Specific PDU's |
| 1.3.6.1.4.1.4756.20.730.20.1.355 | Columnf2000EASPort1TxUnsupportedCodesLocal | read-only | current | f2000EAS Series card Port1 Detailed Link OAM Statistics: Tx Unsupported Codes |
| 1.3.6.1.4.1.4756.20.730.20.1.356 | Columnf2000EASPort1TxLinkFaultPDULocal | read-only | current | f2000EAS Series card Port1 Detailed Link OAM Statistics: Tx Link Fault PDU's |
| 1.3.6.1.4.1.4756.20.730.20.1.357 | Columnf2000EASPort1TxDyingGaspLocal | read-only | current | f2000EAS Series card Port1 Detailed Link OAM Statistics: Tx Dying Gasp |
| 1.3.6.1.4.1.4756.20.730.20.1.358 | Columnf2000EASPort1TxCriticalEventPDULocal | read-only | current | f2000EAS Series card Port1 Detailed Link OAM Statistics: Tx Dying Gasp |
| 1.3.6.1.4.1.4756.20.730.20.1.359 | Columnf2000EASPort2RxOAMInfoPDULocal | read-only | current | f2000EAS Series card Port2 Detailed Link OAM Statistics: Rx OAM Information PDU's |
| 1.3.6.1.4.1.4756.20.730.20.1.360 | Columnf2000EASPort2RxUniqueErrorEventLocal | read-only | current | f2000EAS Series card Port2 Detailed Link OAM Statistics: Rx Unique Error Event Notificatio |
| 1.3.6.1.4.1.4756.20.730.20.1.361 | Columnf2000EASPort2RxDuplicateErrorEventLocal | read-only | current | f2000EAS Series card Port2 Detailed Link OAM Statistics: Rx Duplicate Error Event Notification |
| 1.3.6.1.4.1.4756.20.730.20.1.362 | Columnf2000EASPort2RxLoopBackControlLocal | read-only | current | f2000EAS Series card Port2 Detailed Link OAM Statistics: Rx Loopback Control |
| 1.3.6.1.4.1.4756.20.730.20.1.363 | Columnf2000EASPort2RxVariableRequestLocal | read-only | current | f2000EAS Series card Port2 Detailed Link OAM Statistics: Rx Variable Request |
| 1.3.6.1.4.1.4756.20.730.20.1.364 | Columnf2000EASPort2RxVariableResponseLocal | read-only | current | f2000EAS Series card Port2 Detailed Link OAM Statistics: Rx Variable Response |
| 1.3.6.1.4.1.4756.20.730.20.1.365 | Columnf2000EASPort2RxOrgSpecificPDULocal | read-only | current | f2000EAS Series card Port2 Detailed Link OAM Statistics: Rx Org Specific PDU's |
| 1.3.6.1.4.1.4756.20.730.20.1.366 | Columnf2000EASPort2RxUnsupportedCodesLocal | read-only | current | f2000EAS Series card Port2 Detailed Link OAM Statistics: Rx Unsupported Codes |
| 1.3.6.1.4.1.4756.20.730.20.1.367 | Columnf2000EASPort2RxLinkFaultPDULocal | read-only | current | f2000EAS Series card Port2 Detailed Link OAM Statistics: Rx Link Fault PDU's |
| 1.3.6.1.4.1.4756.20.730.20.1.368 | Columnf2000EASPort2RxDyingGaspLocal | read-only | current | f2000EAS Series card Port2 Detailed Link OAM Statistics: Rx Dying Gasp |
| 1.3.6.1.4.1.4756.20.730.20.1.369 | Columnf2000EASPort2RxCriticalEventPDULocal | read-only | current | f2000EAS Series card Port2 Detailed Link OAM Statistics: Rx Dying Gasp |
| 1.3.6.1.4.1.4756.20.730.20.1.370 | Columnf2000EASPort2TxOAMInfoPDULocal | read-only | current | f2000EAS Series card Port2 Detailed Link OAM Statistics: Tx OAM Information PDU's |
| 1.3.6.1.4.1.4756.20.730.20.1.371 | Columnf2000EASPort2TxUniqueErrorEventLocal | read-only | current | f2000EAS Series card Port2 Detailed Link OAM Statistics: Tx Unique Error Event Notificatio |
| 1.3.6.1.4.1.4756.20.730.20.1.372 | Columnf2000EASPort2TxDuplicateErrorEventLocal | read-only | current | f2000EAS Series card Port2 Detailed Link OAM Statistics: Tx Duplicate Error Event Notification |
| 1.3.6.1.4.1.4756.20.730.20.1.373 | Columnf2000EASPort2TxLoopBackControlLocal | read-only | current | f2000EAS Series card Port2 Detailed Link OAM Statistics: Tx Loopback Control |
| 1.3.6.1.4.1.4756.20.730.20.1.374 | Columnf2000EASPort2TxVariableRequestLocal | read-only | current | f2000EAS Series card Port2 Detailed Link OAM Statistics: Tx Variable Request |
| 1.3.6.1.4.1.4756.20.730.20.1.375 | Columnf2000EASPort2TxVariableResponseLocal | read-only | current | f2000EAS Series card Port2 Detailed Link OAM Statistics: Tx Variable Response |
| 1.3.6.1.4.1.4756.20.730.20.1.376 | Columnf2000EASPort2TxOrgSpecificPDULocal | read-only | current | f2000EAS Series card Port2 Detailed Link OAM Statistics: Tx Org Specific PDU's |
| 1.3.6.1.4.1.4756.20.730.20.1.377 | Columnf2000EASPort2TxUnsupportedCodesLocal | read-only | current | f2000EAS Series card Port2 Detailed Link OAM Statistics: Tx Unsupported Codes |
| 1.3.6.1.4.1.4756.20.730.20.1.378 | Columnf2000EASPort2TxLinkFaultPDULocal | read-only | current | f2000EAS Series card Port2 Detailed Link OAM Statistics: Tx Link Fault PDU's |
| 1.3.6.1.4.1.4756.20.730.20.1.379 | Columnf2000EASPort2TxDyingGaspLocal | read-only | current | f2000EAS Series card Port2 Detailed Link OAM Statistics: Tx Dying Gasp |
| 1.3.6.1.4.1.4756.20.730.20.1.380 | Columnf2000EASPort2TxCriticalEventPDULocal | read-only | current | f2000EAS Series card Port2 Detailed Link OAM Statistics: Tx Dying Gasp |
| 1.3.6.1.4.1.4756.20.730.20.1.381 | Columnf2000EASPort3RxOAMInfoPDULocal | read-only | current | f2000EAS Series card Port3 Detailed Link OAM Statistics: Rx OAM Information PDU's |
| 1.3.6.1.4.1.4756.20.730.20.1.382 | Columnf2000EASPort3RxUniqueErrorEventLocal | read-only | current | f2000EAS Series card Port3 Detailed Link OAM Statistics: Rx Unique Error Event Notificatio |
| 1.3.6.1.4.1.4756.20.730.20.1.383 | Columnf2000EASPort3RxDuplicateErrorEventLocal | read-only | current | f2000EAS Series card Port3 Detailed Link OAM Statistics: Rx Duplicate Error Event Notification |
| 1.3.6.1.4.1.4756.20.730.20.1.384 | Columnf2000EASPort3RxLoopBackControlLocal | read-only | current | f2000EAS Series card Port3 Detailed Link OAM Statistics: Rx Loopback Control |
| 1.3.6.1.4.1.4756.20.730.20.1.385 | Columnf2000EASPort3RxVariableRequestLocal | read-only | current | f2000EAS Series card Port3 Detailed Link OAM Statistics: Rx Variable Request |
| 1.3.6.1.4.1.4756.20.730.20.1.386 | Columnf2000EASPort3RxVariableResponseLocal | read-only | current | f2000EAS Series card Port3 Detailed Link OAM Statistics: Rx Variable Response |
| 1.3.6.1.4.1.4756.20.730.20.1.387 | Columnf2000EASPort3RxOrgSpecificPDULocal | read-only | current | f2000EAS Series card Port3 Detailed Link OAM Statistics: Rx Org Specific PDU's |
| 1.3.6.1.4.1.4756.20.730.20.1.388 | Columnf2000EASPort3RxUnsupportedCodesLocal | read-only | current | f2000EAS Series card Port3 Detailed Link OAM Statistics: Rx Unsupported Codes |
| 1.3.6.1.4.1.4756.20.730.20.1.389 | Columnf2000EASPort3RxLinkFaultPDULocal | read-only | current | f2000EAS Series card Port3 Detailed Link OAM Statistics: Rx Link Fault PDU's |
| 1.3.6.1.4.1.4756.20.730.20.1.390 | Columnf2000EASPort3RxDyingGaspLocal | read-only | current | f2000EAS Series card Port3 Detailed Link OAM Statistics: Rx Dying Gasp |
| 1.3.6.1.4.1.4756.20.730.20.1.391 | Columnf2000EASPort3RxCriticalEventPDULocal | read-only | current | f2000EAS Series card Port3 Detailed Link OAM Statistics: Rx Dying Gasp |
| 1.3.6.1.4.1.4756.20.730.20.1.392 | Columnf2000EASPort3TxOAMInfoPDULocal | read-only | current | f2000EAS Series card Port3 Detailed Link OAM Statistics: Tx OAM Information PDU's |
| 1.3.6.1.4.1.4756.20.730.20.1.393 | Columnf2000EASPort3TxUniqueErrorEventLocal | read-only | current | f2000EAS Series card Port3 Detailed Link OAM Statistics: Tx Unique Error Event Notificatio |
| 1.3.6.1.4.1.4756.20.730.20.1.394 | Columnf2000EASPort3TxDuplicateErrorEventLocal | read-only | current | f2000EAS Series card Port3 Detailed Link OAM Statistics: Tx Duplicate Error Event Notification |
| 1.3.6.1.4.1.4756.20.730.20.1.395 | Columnf2000EASPort3TxLoopBackControlLocal | read-only | current | f2000EAS Series card Port3 Detailed Link OAM Statistics: Tx Loopback Control |
| 1.3.6.1.4.1.4756.20.730.20.1.396 | Columnf2000EASPort3TxVariableRequestLocal | read-only | current | f2000EAS Series card Port3 Detailed Link OAM Statistics: Tx Variable Request |
| 1.3.6.1.4.1.4756.20.730.20.1.397 | Columnf2000EASPort3TxVariableResponseLocal | read-only | current | f2000EAS Series card Port3 Detailed Link OAM Statistics: Tx Variable Response |
| 1.3.6.1.4.1.4756.20.730.20.1.398 | Columnf2000EASPort3TxOrgSpecificPDULocal | read-only | current | f2000EAS Series card Port3 Detailed Link OAM Statistics: Tx Org Specific PDU's |
| 1.3.6.1.4.1.4756.20.730.20.1.399 | Columnf2000EASPort3TxUnsupportedCodesLocal | read-only | current | f2000EAS Series card Port3 Detailed Link OAM Statistics: Tx Unsupported Codes |
| 1.3.6.1.4.1.4756.20.730.20.1.400 | Columnf2000EASPort3TxLinkFaultPDULocal | read-only | current | f2000EAS Series card Port3 Detailed Link OAM Statistics: Tx Link Fault PDU's |
| 1.3.6.1.4.1.4756.20.730.20.1.401 | Columnf2000EASPort3TxDyingGaspLocal | read-only | current | f2000EAS Series card Port3 Detailed Link OAM Statistics: Tx Dying Gasp |
| 1.3.6.1.4.1.4756.20.730.20.1.402 | Columnf2000EASPort3TxCriticalEventPDULocal | read-only | current | f2000EAS Series card Port3 Detailed Link OAM Statistics: Tx Dying Gasp |
| 1.3.6.1.4.1.4756.20.730.20.1.403 | Columnf2000EASPort4RxOAMInfoPDULocal | read-only | current | f2000EAS Series card Port4 Detailed Link OAM Statistics: Rx OAM Information PDU's |
| 1.3.6.1.4.1.4756.20.730.20.1.404 | Columnf2000EASPort4RxUniqueErrorEventLocal | read-only | current | f2000EAS Series card Port4 Detailed Link OAM Statistics: Rx Unique Error Event Notificatio |
| 1.3.6.1.4.1.4756.20.730.20.1.405 | Columnf2000EASPort4RxDuplicateErrorEventLocal | read-only | current | f2000EAS Series card Port4 Detailed Link OAM Statistics: Rx Duplicate Error Event Notification |
| 1.3.6.1.4.1.4756.20.730.20.1.406 | Columnf2000EASPort4RxLoopBackControlLocal | read-only | current | f2000EAS Series card Port4 Detailed Link OAM Statistics: Rx Loopback Control |
| 1.3.6.1.4.1.4756.20.730.20.1.407 | Columnf2000EASPort4RxVariableRequestLocal | read-only | current | f2000EAS Series card Port4 Detailed Link OAM Statistics: Rx Variable Request |
| 1.3.6.1.4.1.4756.20.730.20.1.408 | Columnf2000EASPort4RxVariableResponseLocal | read-only | current | f2000EAS Series card Port4 Detailed Link OAM Statistics: Rx Variable Response |
| 1.3.6.1.4.1.4756.20.730.20.1.409 | Columnf2000EASPort4RxOrgSpecificPDULocal | read-only | current | f2000EAS Series card Port4 Detailed Link OAM Statistics: Rx Org Specific PDU's |
| 1.3.6.1.4.1.4756.20.730.20.1.410 | Columnf2000EASPort4RxUnsupportedCodesLocal | read-only | current | f2000EAS Series card Port4 Detailed Link OAM Statistics: Rx Unsupported Codes |
| 1.3.6.1.4.1.4756.20.730.20.1.411 | Columnf2000EASPort4RxLinkFaultPDULocal | read-only | current | f2000EAS Series card Port4 Detailed Link OAM Statistics: Rx Link Fault PDU's |
| 1.3.6.1.4.1.4756.20.730.20.1.412 | Columnf2000EASPort4RxDyingGaspLocal | read-only | current | f2000EAS Series card Port4 Detailed Link OAM Statistics: Rx Dying Gasp |
| 1.3.6.1.4.1.4756.20.730.20.1.413 | Columnf2000EASPort4RxCriticalEventPDULocal | read-only | current | f2000EAS Series card Port4 Detailed Link OAM Statistics: Rx Dying Gasp |
| 1.3.6.1.4.1.4756.20.730.20.1.414 | Columnf2000EASPort4TxOAMInfoPDULocal | read-only | current | f2000EAS Series card Port4 Detailed Link OAM Statistics: Tx OAM Information PDU's |
| 1.3.6.1.4.1.4756.20.730.20.1.415 | Columnf2000EASPort4TxUniqueErrorEventLocal | read-only | current | f2000EAS Series card Port4 Detailed Link OAM Statistics: Tx Unique Error Event Notificatio |
| 1.3.6.1.4.1.4756.20.730.20.1.416 | Columnf2000EASPort4TxDuplicateErrorEventLocal | read-only | current | f2000EAS Series card Port4 Detailed Link OAM Statistics: Tx Duplicate Error Event Notification |
| 1.3.6.1.4.1.4756.20.730.20.1.417 | Columnf2000EASPort4TxLoopBackControlLocal | read-only | current | f2000EAS Series card Port4 Detailed Link OAM Statistics: Tx Loopback Control |
| 1.3.6.1.4.1.4756.20.730.20.1.418 | Columnf2000EASPort4TxVariableRequestLocal | read-only | current | f2000EAS Series card Port4 Detailed Link OAM Statistics: Tx Variable Request |
| 1.3.6.1.4.1.4756.20.730.20.1.419 | Columnf2000EASPort4TxVariableResponseLocal | read-only | current | f2000EAS Series card Port4 Detailed Link OAM Statistics: Tx Variable Response |
| 1.3.6.1.4.1.4756.20.730.20.1.420 | Columnf2000EASPort4TxOrgSpecificPDULocal | read-only | current | f2000EAS Series card Port4 Detailed Link OAM Statistics: Tx Org Specific PDU's |
| 1.3.6.1.4.1.4756.20.730.20.1.421 | Columnf2000EASPort4TxUnsupportedCodesLocal | read-only | current | f2000EAS Series card Port4 Detailed Link OAM Statistics: Tx Unsupported Codes |
| 1.3.6.1.4.1.4756.20.730.20.1.422 | Columnf2000EASPort4TxLinkFaultPDULocal | read-only | current | f2000EAS Series card Port4 Detailed Link OAM Statistics: Tx Link Fault PDU's |
| 1.3.6.1.4.1.4756.20.730.20.1.423 | Columnf2000EASPort4TxDyingGaspLocal | read-only | current | f2000EAS Series card Port4 Detailed Link OAM Statistics: Tx Dying Gasp |
| 1.3.6.1.4.1.4756.20.730.20.1.424 | Columnf2000EASPort4TxCriticalEventPDULocal | read-only | current | f2000EAS Series card Port4 Detailed Link OAM Statistics: Tx Dying Gasp |
| 1.3.6.1.4.1.4756.20.730.20.1.425 | Columnf2000EASPort1PDUPermisionLocal | read-only | current | f2000EAS Series card Detailed Link OAM Status for Port 1: PDU Permission |
| 1.3.6.1.4.1.4756.20.730.20.1.426 | Columnf2000EASPort1DiscoveryStateLocal | read-only | current | f2000EAS Series card Detailed Link OAM Status for Port 1: Discovery State |
| 1.3.6.1.4.1.4756.20.730.20.1.427 | Columnf2000EASPort1PeerMACAddrLocal | read-only | current | f2000EAS Series card Detailed Link OAM Status for Port 1: Discovery State |
| 1.3.6.1.4.1.4756.20.730.20.1.428 | Columnf2000EASPort1LocalModeLocal | read-only | current | f2000EAS Series card Detailed Link OAM Status for Port 1: Local: Mode |
| 1.3.6.1.4.1.4756.20.730.20.1.429 | Columnf2000EASPort1LocalUnOperationLocal | read-only | current | f2000EAS Series card Detailed Link OAM Status for Port 1: Local: Unidirectional Operation Support |
| 1.3.6.1.4.1.4756.20.730.20.1.430 | Columnf2000EASPort1LocalRemoteLbLocal | read-only | current | f2000EAS Series card Detailed Link OAM Status for Port 1: Local: Remote Loopback Support |
| 1.3.6.1.4.1.4756.20.730.20.1.431 | Columnf2000EASPort1LocalLMLocal | read-only | current | f2000EAS Series card Detailed Link OAM Status for Port 1: RemoteA: Link Monitoring Support |
| 1.3.6.1.4.1.4756.20.730.20.1.432 | Columnf2000EASPort1LocalMIBRetrievalLocal | read-only | current | f2000EAS Series card Detailed Link OAM Status for Port 1: RemoteA: MIB Retrieval Support |
| 1.3.6.1.4.1.4756.20.730.20.1.433 | Columnf2000EASPort1LocalMTUSizeLocal | read-only | current | f2000EAS Series card Detailed Link OAM Status for Port 1: RemoteA: MTU Size |
| 1.3.6.1.4.1.4756.20.730.20.1.434 | Columnf2000EASPort1LocalMultiStateLocal | read-only | current | f2000EAS Series card Detailed Link OAM Status for Port 1: RemoteA: Multiplexer State |
| 1.3.6.1.4.1.4756.20.730.20.1.435 | Columnf2000EASPort1LocalParserStateLocal | read-only | current | f2000EAS Series card Detailed Link OAM Status for Port 1: RemoteA: Multiplexer State |
| 1.3.6.1.4.1.4756.20.730.20.1.436 | Columnf2000EASPort1LocalOUILocal | read-only | current | f2000EAS Series card Detailed Link OAM Status for Port 1: RemoteA: Organizational Unique Identification |
| 1.3.6.1.4.1.4756.20.730.20.1.437 | Columnf2000EASPort1LocalPDURevLocal | read-only | current | f2000EAS Series card Detailed Link OAM Status for Port 1: RemoteA: PDU Revision |
| 1.3.6.1.4.1.4756.20.730.20.1.438 | Columnf2000EASPort1PeerModeLocal | read-only | current | f2000EAS Series card Detailed Link OAM Status for Port 1: Peer: Mode |
| 1.3.6.1.4.1.4756.20.730.20.1.439 | Columnf2000EASPort1PeerUnOperationLocal | read-only | current | f2000EAS Series card Detailed Link OAM Status for Port 1: Peer: Unidirectional Operation Support |
| 1.3.6.1.4.1.4756.20.730.20.1.440 | Columnf2000EASPort1PeerRemoteLbLocal | read-only | current | f2000EAS Series card Detailed Link OAM Status for Port 1: Peer: Remote Loopback Support |
| 1.3.6.1.4.1.4756.20.730.20.1.441 | Columnf2000EASPort1PeerLMLocal | read-only | current | f2000EAS Series card Detailed Link OAM Status for Port 1: Peer: Link Monitoring Support |
| 1.3.6.1.4.1.4756.20.730.20.1.442 | Columnf2000EASPort1PeerMIBRetrievalLocal | read-only | current | f2000EAS Series card Detailed Link OAM Status for Port 1: Peer: MIB Retrieval Support |
| 1.3.6.1.4.1.4756.20.730.20.1.443 | Columnf2000EASPort1PeerMTUSizeLocal | read-only | current | f2000EAS Series card Detailed Link OAM Status for Port 1: Peer: MTU Size |
| 1.3.6.1.4.1.4756.20.730.20.1.444 | Columnf2000EASPort1PeerMultiStateLocal | read-only | current | f2000EAS Series card Detailed Link OAM Status for Port 1: Peer: Multiplexer State |
| 1.3.6.1.4.1.4756.20.730.20.1.445 | Columnf2000EASPort1PeerParserStateLocal | read-only | current | f2000EAS Series card Detailed Link OAM Status for Port 1: Peer: Multiplexer State |
| 1.3.6.1.4.1.4756.20.730.20.1.446 | Columnf2000EASPort1PeerOUILocal | read-only | current | f2000EAS Series card Detailed Link OAM Status for Port 1: Peer: Organizational Unique Identification |
| 1.3.6.1.4.1.4756.20.730.20.1.447 | Columnf2000EASPort1PeerPDURevLocal | read-only | current | f2000EAS Series card Detailed Link OAM Status for Port 1: Peer: PDU Revision |
| 1.3.6.1.4.1.4756.20.730.20.1.448 | Columnf2000EASPort2PDUPermisionLocal | read-only | current | f2000EAS Series card Detailed Link OAM Status for Port 2: PDU Permission |
| 1.3.6.1.4.1.4756.20.730.20.1.449 | Columnf2000EASPort2DiscoveryStateLocal | read-only | current | f2000EAS Series card Detailed Link OAM Status for Port 2: Discovery State |
| 1.3.6.1.4.1.4756.20.730.20.1.450 | Columnf2000EASPort2PeerMACAddrLocal | read-only | current | f2000EAS Series card Detailed Link OAM Status for Port 2: Discovery State |
| 1.3.6.1.4.1.4756.20.730.20.1.451 | Columnf2000EASPort2LocalModeLocal | read-only | current | f2000EAS Series card Detailed Link OAM Status for Port 2: RemoteA: Mode |
| 1.3.6.1.4.1.4756.20.730.20.1.452 | Columnf2000EASPort2LocalUnOperationLocal | read-only | current | f2000EAS Series card Detailed Link OAM Status for Port 2: RemoteA: Unidirectional Operation Support |
| 1.3.6.1.4.1.4756.20.730.20.1.453 | Columnf2000EASPort2LocalRemoteLbLocal | read-only | current | f2000EAS Series card Detailed Link OAM Status for Port 2: RemoteA: Remote Loopback Support |
| 1.3.6.1.4.1.4756.20.730.20.1.454 | Columnf2000EASPort2LocalLMLocal | read-only | current | f2000EAS Series card Detailed Link OAM Status for Port 2: RemoteA: Link Monitoring Support |
| 1.3.6.1.4.1.4756.20.730.20.1.455 | Columnf2000EASPort2LocalMIBRetrievalLocal | read-only | current | f2000EAS Series card Detailed Link OAM Status for Port 2: RemoteA: MIB Retrieval Support |
| 1.3.6.1.4.1.4756.20.730.20.1.456 | Columnf2000EASPort2LocalMTUSizeLocal | read-only | current | f2000EAS Series card Detailed Link OAM Status for Port 2: RemoteA: MTU Size |
| 1.3.6.1.4.1.4756.20.730.20.1.457 | Columnf2000EASPort2LocalMultiStateLocal | read-only | current | f2000EAS Series card Detailed Link OAM Status for Port 2: RemoteA: Multiplexer State |
| 1.3.6.1.4.1.4756.20.730.20.1.458 | Columnf2000EASPort2LocalParserStateLocal | read-only | current | f2000EAS Series card Detailed Link OAM Status for Port 2: RemoteA: Multiplexer State |
| 1.3.6.1.4.1.4756.20.730.20.1.459 | Columnf2000EASPort2LocalOUILocal | read-only | current | f2000EAS Series card Detailed Link OAM Status for Port 2: RemoteA: Organizational Unique Identification |
| 1.3.6.1.4.1.4756.20.730.20.1.460 | Columnf2000EASPort2LocalPDURevLocal | read-only | current | f2000EAS Series card Detailed Link OAM Status for Port 2: RemoteA: PDU Revision |
| 1.3.6.1.4.1.4756.20.730.20.1.461 | Columnf2000EASPort2PeerModeLocal | read-only | current | f2000EAS Series card Detailed Link OAM Status for Port 2: Peer: Mode |
| 1.3.6.1.4.1.4756.20.730.20.1.462 | Columnf2000EASPort2PeerUnOperationLocal | read-only | current | f2000EAS Series card Detailed Link OAM Status for Port 2: Peer: Unidirectional Operation Support |
| 1.3.6.1.4.1.4756.20.730.20.1.463 | Columnf2000EASPort2PeerRemoteLbLocal | read-only | current | f2000EAS Series card Detailed Link OAM Status for Port 2: Peer: Remote Loopback Support |
| 1.3.6.1.4.1.4756.20.730.20.1.464 | Columnf2000EASPort2PeerLMLocal | read-only | current | f2000EAS Series card Detailed Link OAM Status for Port 2: Peer: Link Monitoring Support |
| 1.3.6.1.4.1.4756.20.730.20.1.465 | Columnf2000EASPort2PeerMIBRetrievalLocal | read-only | current | f2000EAS Series card Detailed Link OAM Status for Port 2: Peer: MIB Retrieval Support |
| 1.3.6.1.4.1.4756.20.730.20.1.466 | Columnf2000EASPort2PeerMTUSizeLocal | read-only | current | f2000EAS Series card Detailed Link OAM Status for Port 2: Peer: MTU Size |
| 1.3.6.1.4.1.4756.20.730.20.1.467 | Columnf2000EASPort2PeerMultiStateLocal | read-only | current | f2000EAS Series card Detailed Link OAM Status for Port 2: Peer: Multiplexer State |
| 1.3.6.1.4.1.4756.20.730.20.1.468 | Columnf2000EASPort2PeerParserStateLocal | read-only | current | f2000EAS Series card Detailed Link OAM Status for Port 2: Peer: Multiplexer State |
| 1.3.6.1.4.1.4756.20.730.20.1.469 | Columnf2000EASPort2PeerOUILocal | read-only | current | f2000EAS Series card Detailed Link OAM Status for Port 2: Peer: Organizational Unique Identification |
| 1.3.6.1.4.1.4756.20.730.20.1.470 | Columnf2000EASPort2PeerPDURevLocal | read-only | current | f2000EAS Series card Detailed Link OAM Status for Port 2: Peer: PDU Revision |
| 1.3.6.1.4.1.4756.20.730.20.1.471 | Columnf2000EASPort3PDUPermisionLocal | read-only | current | f2000EAS Series card Detailed Link OAM Status for Port 3: PDU Permission |
| 1.3.6.1.4.1.4756.20.730.20.1.472 | Columnf2000EASPort3DiscoveryStateLocal | read-only | current | f2000EAS Series card Detailed Link OAM Status for Port 3: Discovery State |
| 1.3.6.1.4.1.4756.20.730.20.1.473 | Columnf2000EASPort3PeerMACAddrLocal | read-only | current | f2000EAS Series card Detailed Link OAM Status for Port 3: Discovery State |
| 1.3.6.1.4.1.4756.20.730.20.1.474 | Columnf2000EASPort3LocalModeLocal | read-only | current | f2000EAS Series card Detailed Link OAM Status for Port 3: Local: Mode |
| 1.3.6.1.4.1.4756.20.730.20.1.475 | Columnf2000EASPort3LocalUnOperationLocal | read-only | current | f2000EAS Series card Detailed Link OAM Status for Port 3: Local: Unidirectional Operation Support |
| 1.3.6.1.4.1.4756.20.730.20.1.476 | Columnf2000EASPort3LocalRemoteLbLocal | read-only | current | f2000EAS Series card Detailed Link OAM Status for Port 3: Local: Remote Loopback Support |
| 1.3.6.1.4.1.4756.20.730.20.1.477 | Columnf2000EASPort3LocalLMLocal | read-only | current | f2000EAS Series card Detailed Link OAM Status for Port 3: Local: Link Monitoring Support |
| 1.3.6.1.4.1.4756.20.730.20.1.478 | Columnf2000EASPort3LocalMIBRetrievalLocal | read-only | current | f2000EAS Series card Detailed Link OAM Status for Port 3: Local: MIB Retrieval Support |
| 1.3.6.1.4.1.4756.20.730.20.1.479 | Columnf2000EASPort3LocalMTUSizeLocal | read-only | current | f2000EAS Series card Detailed Link OAM Status for Port 3: Local: MTU Size |
| 1.3.6.1.4.1.4756.20.730.20.1.480 | Columnf2000EASPort3LocalMultiStateLocal | read-only | current | f2000EAS Series card Detailed Link OAM Status for Port 3: Local: Multiplexer State |
| 1.3.6.1.4.1.4756.20.730.20.1.481 | Columnf2000EASPort3LocalParserStateLocal | read-only | current | f2000EAS Series card Detailed Link OAM Status for Port 3: Local: Multiplexer State |
| 1.3.6.1.4.1.4756.20.730.20.1.482 | Columnf2000EASPort3LocalOUILocal | read-only | current | f2000EAS Series card Detailed Link OAM Status for Port 3: Local: Organizational Unique Identification |
| 1.3.6.1.4.1.4756.20.730.20.1.483 | Columnf2000EASPort3LocalPDURevLocal | read-only | current | f2000EAS Series card Detailed Link OAM Status for Port 3: Local: PDU Revision |
| 1.3.6.1.4.1.4756.20.730.20.1.484 | Columnf2000EASPort3PeerModeLocal | read-only | current | f2000EAS Series card Detailed Link OAM Status for Port 3: Peer: Mode |
| 1.3.6.1.4.1.4756.20.730.20.1.485 | Columnf2000EASPort3PeerUnOperationLocal | read-only | current | f2000EAS Series card Detailed Link OAM Status for Port 3: Peer: Unidirectional Operation Support |
| 1.3.6.1.4.1.4756.20.730.20.1.486 | Columnf2000EASPort3PeerRemoteLbLocal | read-only | current | f2000EAS Series card Detailed Link OAM Status for Port 3: Peer: Remote Loopback Support |
| 1.3.6.1.4.1.4756.20.730.20.1.487 | Columnf2000EASPort3PeerLMLocal | read-only | current | f2000EAS Series card Detailed Link OAM Status for Port 3: Peer: Link Monitoring Support |
| 1.3.6.1.4.1.4756.20.730.20.1.488 | Columnf2000EASPort3PeerMIBRetrievalLocal | read-only | current | f2000EAS Series card Detailed Link OAM Status for Port 3: Peer: MIB Retrieval Support |
| 1.3.6.1.4.1.4756.20.730.20.1.489 | Columnf2000EASPort3PeerMTUSizeLocal | read-only | current | f2000EAS Series card Detailed Link OAM Status for Port 3: Peer: MTU Size |
| 1.3.6.1.4.1.4756.20.730.20.1.490 | Columnf2000EASPort3PeerMultiStateLocal | read-only | current | f2000EAS Series card Detailed Link OAM Status for Port 3: Peer: Multiplexer State |
| 1.3.6.1.4.1.4756.20.730.20.1.491 | Columnf2000EASPort3PeerParserStateLocal | read-only | current | f2000EAS Series card Detailed Link OAM Status for Port 3: Peer: Multiplexer State |
| 1.3.6.1.4.1.4756.20.730.20.1.492 | Columnf2000EASPort3PeerOUILocal | read-only | current | f2000EAS Series card Detailed Link OAM Status for Port 3: Peer: Organizational Unique Identification |
| 1.3.6.1.4.1.4756.20.730.20.1.493 | Columnf2000EASPort3PeerPDURevLocal | read-only | current | f2000EAS Series card Detailed Link OAM Status for Port 3: Peer: PDU Revision |
| 1.3.6.1.4.1.4756.20.730.20.1.494 | Columnf2000EASPort4PDUPermisionLocal | read-only | current | f2000EAS Series card Detailed Link OAM Status for Port 4: PDU Permission |
| 1.3.6.1.4.1.4756.20.730.20.1.495 | Columnf2000EASPort4DiscoveryStateLocal | read-only | current | f2000EAS Series card Detailed Link OAM Status for Port 4: Discovery State |
| 1.3.6.1.4.1.4756.20.730.20.1.496 | Columnf2000EASPort4PeerMACAddrLocal | read-only | current | f2000EAS Series card Detailed Link OAM Status for Port 4: Discovery State |
| 1.3.6.1.4.1.4756.20.730.20.1.497 | Columnf2000EASPort4LocalModeLocal | read-only | current | f2000EAS Series card Detailed Link OAM Status for Port 4: Local: Mode |
| 1.3.6.1.4.1.4756.20.730.20.1.498 | Columnf2000EASPort4LocalUnOperationLocal | read-only | current | f2000EAS Series card Detailed Link OAM Status for Port 4: Local: Unidirectional Operation Support |
| 1.3.6.1.4.1.4756.20.730.20.1.499 | Columnf2000EASPort4LocalRemoteLbLocal | read-only | current | f2000EAS Series card Detailed Link OAM Status for Port 4: Local: Remote Loopback Support |
| 1.3.6.1.4.1.4756.20.730.20.1.500 | Columnf2000EASPort4LocalLMLocal | read-only | current | f2000EAS Series card Detailed Link OAM Status for Port 4: Local: Link Monitoring Support |
| 1.3.6.1.4.1.4756.20.730.20.1.501 | Columnf2000EASPort4LocalMIBRetrievalLocal | read-only | current | f2000EAS Series card Detailed Link OAM Status for Port 4: Local: MIB Retrieval Support |
| 1.3.6.1.4.1.4756.20.730.20.1.502 | Columnf2000EASPort4LocalMTUSizeLocal | read-only | current | f2000EAS Series card Detailed Link OAM Status for Port 4: Local: MTU Size |
| 1.3.6.1.4.1.4756.20.730.20.1.503 | Columnf2000EASPort4LocalMultiStateLocal | read-only | current | f2000EAS Series card Detailed Link OAM Status for Port 4: Local: Multiplexer State |
| 1.3.6.1.4.1.4756.20.730.20.1.504 | Columnf2000EASPort4LocalParserStateLocal | read-only | current | f2000EAS Series card Detailed Link OAM Status for Port 4: Local: Multiplexer State |
| 1.3.6.1.4.1.4756.20.730.20.1.505 | Columnf2000EASPort4LocalOUILocal | read-only | current | f2000EAS Series card Detailed Link OAM Status for Port 4: Local: Organizational Unique Identification |
| 1.3.6.1.4.1.4756.20.730.20.1.506 | Columnf2000EASPort4LocalPDURevLocal | read-only | current | f2000EAS Series card Detailed Link OAM Status for Port 4: Local: PDU Revision |
| 1.3.6.1.4.1.4756.20.730.20.1.507 | Columnf2000EASPort4PeerModeLocal | read-only | current | f2000EAS Series card Detailed Link OAM Status for Port 4: Peer: Mode |
| 1.3.6.1.4.1.4756.20.730.20.1.508 | Columnf2000EASPort4PeerUnOperationLocal | read-only | current | f2000EAS Series card Detailed Link OAM Status for Port 4: Peer: Unidirectional Operation Support |
| 1.3.6.1.4.1.4756.20.730.20.1.509 | Columnf2000EASPort4PeerRemoteLbLocal | read-only | current | f2000EAS Series card Detailed Link OAM Status for Port 4: Peer: Remote Loopback Support |
| 1.3.6.1.4.1.4756.20.730.20.1.510 | Columnf2000EASPort4PeerLMLocal | read-only | current | f2000EAS Series card Detailed Link OAM Status for Port 4: Peer: Link Monitoring Support |
| 1.3.6.1.4.1.4756.20.730.20.1.511 | Columnf2000EASPort4PeerMIBRetrievalLocal | read-only | current | f2000EAS Series card Detailed Link OAM Status for Port 4: Peer: MIB Retrieval Support |
| 1.3.6.1.4.1.4756.20.730.20.1.512 | Columnf2000EASPort4PeerMTUSizeLocal | read-only | current | EDD Series card Detailed Link OAM Status for Port 4: Peer: MTU Size |
| 1.3.6.1.4.1.4756.20.730.20.1.513 | Columnf2000EASPort4PeerMultiStateLocal | read-only | current | f2000EAS Series card Detailed Link OAM Status for Port 4: Peer: Multiplexer State |
| 1.3.6.1.4.1.4756.20.730.20.1.514 | Columnf2000EASPort4PeerParserStateLocal | read-only | current | f2000EAS Series card Detailed Link OAM Status for Port 4: Peer: Multiplexer State |
| 1.3.6.1.4.1.4756.20.730.20.1.515 | Columnf2000EASPort4PeerOUILocal | read-only | current | f2000EAS Series card Detailed Link OAM Status for Port 4: Peer: Organizational Unique Identification |
| 1.3.6.1.4.1.4756.20.730.20.1.516 | Columnf2000EASPort4PeerPDURevLocal | read-only | current | f2000EAS Series card Detailed Link OAM Status for Port 4: Peer: PDU Revision |
| 1.3.6.1.4.1.4756.20.730.20.1.517 | Columnf2000EASCLEAROAMCOUNTERLocal | read-write | current | f2000EAS Series card Clear OAM Counter: 0: Off 1: Action |
| 1.3.6.1.4.1.4756.20.730.20.1.518 | Columnf2000EASLoopProtectionEnableLocal | read-write | current | f2000EAS Series card Loop Protection Configuration: General Settings - Enable Loop Protection 0: Disable 1: Enable |
| 1.3.6.1.4.1.4756.20.730.20.1.519 | Columnf2000EASLoopProtectionTxTimeLocal | read-write | current | f2000EAS Series card Loop Protection Configuration: General Settings - Transmission Time |
| 1.3.6.1.4.1.4756.20.730.20.1.520 | Columnf2000EASLoopProtectionShutdownTimeLocal | read-write | current | f2000EAS Series card Loop Protection Configuration: General Settings - Shutdown Time |
| 1.3.6.1.4.1.4756.20.730.20.1.521 | Columnf2000EASLoopProtectionPort1EnabledLocal | read-write | current | f2000EAS Series card Loop Protection Configuration for Port 1: Port Configuration - Enable 0: Disable 1: Enable |
| 1.3.6.1.4.1.4756.20.730.20.1.522 | Columnf2000EASLoopProtectionPort1ActionLocal | read-write | current | f2000EAS Series card Loop Protection Configuration for Port 1: Port Configuration - Action 0: Shutdown Port 1: Shutdown Port And Log 2: Log Only |
| 1.3.6.1.4.1.4756.20.730.20.1.523 | Columnf2000EASLoopProtectionPort1TxModeLocal | read-write | current | f2000EAS Series card Loop Protection Configuration for Port 1: Port Configuration - Tx Mode 0: Disable 1: Enable |
| 1.3.6.1.4.1.4756.20.730.20.1.524 | Columnf2000EASLoopProtectionPort2EnabledLocal | read-write | current | f2000EAS Series card Loop Protection Configuration for Port 2: Port Configuration - Enable 0: Disable 1: Enable |
| 1.3.6.1.4.1.4756.20.730.20.1.525 | Columnf2000EASLoopProtectionPort2ActionLocal | read-write | current | f2000EAS Series card Loop Protection Configuration for Port 2: Port Configuration - Action 0: Shutdown Port 1: Shutdown Port And Log 2: Log Only |
| 1.3.6.1.4.1.4756.20.730.20.1.526 | Columnf2000EASLoopProtectionPort2TxModeLocal | read-write | current | f2000EAS Series card Loop Protection Configuration for Port 2: Port Configuration - Tx Mode 0: Disable 1: Enable |
| 1.3.6.1.4.1.4756.20.730.20.1.527 | Columnf2000EASLoopProtectionPort3EnabledLocal | read-write | current | f2000EASE Series card Loop Protection Configuration for Port 3: Port Configuration - Enable 0: Disable 1: Enable |
| 1.3.6.1.4.1.4756.20.730.20.1.528 | Columnf2000EASLoopProtectionPort3ActionLocal | read-write | current | f2000EAS Series card Loop Protection Configuration for Port 3: Port Configuration - Action 0: Shutdown Port 1: Shutdown Port And Log 2: Log Only |
| 1.3.6.1.4.1.4756.20.730.20.1.529 | Columnf2000EASLoopProtectionPort3TxModeLocal | read-write | current | f2000EAS Series card Loop Protection Configuration for Port 3: Port Configuration - Tx Mode 0: Disable 1: Enable |
| 1.3.6.1.4.1.4756.20.730.20.1.530 | Columnf2000EASLoopProtectionPort4EnabledLocal | read-write | current | f2000EAS Series card Loop Protection Configuration for Port 4: Port Configuration - Enable 0: Disable 1: Enable |
| 1.3.6.1.4.1.4756.20.730.20.1.531 | Columnf2000EASLoopProtectionPort4ActionLocal | read-write | current | f2000EAS Series card Loop Protection Configuration for Port 4: Port Configuration - Action 0: Shutdown Port 1: Shutdown Port And Log 2: Log Only |
| 1.3.6.1.4.1.4756.20.730.20.1.532 | Columnf2000EASLoopProtectionPort4TxModeLocal | read-write | current | f2000EAS Series card Loop Protection Configuration for Port 41: Port Configuration - Tx Mode 0: Disable 1: Enable |
| 1.3.6.1.4.1.4756.20.730.20.1.533 | Columnf2000EASLoopProtectionPort1ActionStsLocal | read-only | current | f2000EAS Series card Loop Protection Status for Port 1: Action |
| 1.3.6.1.4.1.4756.20.730.20.1.534 | Columnf2000EASLoopProtectionPort1TransStsLocal | read-only | current | f2000EAS Series card Loop Protection Status for Port 1: Transmit |
| 1.3.6.1.4.1.4756.20.730.20.1.535 | Columnf2000EASLoopProtectionPort1LoopsStsLocal | read-only | current | f2000EAS Series card Loop Protection Status for Port 1: Loops |
| 1.3.6.1.4.1.4756.20.730.20.1.536 | Columnf2000EASLoopProtectionPort1StatusLocal | read-only | current | f2000EAS Series card Loop Protection Status for Port 1: Status |
| 1.3.6.1.4.1.4756.20.730.20.1.537 | Columnf2000EASLoopProtectionPort1LoopStsLocal | read-only | current | f2000EAS Series card Loop Protection Status for Port 1: Loop |
| 1.3.6.1.4.1.4756.20.730.20.1.538 | Columnf2000EASLoopProtectionPort2ActionStsLocal | read-only | current | f2000EAS Series card Loop Protection Status for Port 2: Action |
| 1.3.6.1.4.1.4756.20.730.20.1.539 | Columnf2000EASLoopProtectionPort2TransStsLocal | read-only | current | f2000EAS Series card Loop Protection Status for Port 2: Transmit |
| 1.3.6.1.4.1.4756.20.730.20.1.540 | Columnf2000EASLoopProtectionPort2LoopsStsLocal | read-only | current | f2000EAS Series card Loop Protection Status for Port 2: Loops |
| 1.3.6.1.4.1.4756.20.730.20.1.541 | Columnf2000EASLoopProtectionPort2StatusLocal | read-only | current | f2000EAS Series card Loop Protection Status for Port 2: Status |
| 1.3.6.1.4.1.4756.20.730.20.1.542 | Columnf2000EASLoopProtectionPort2LoopStsLocal | read-only | current | f2000EAS Series card Loop Protection Status for Port 2: Loop |
| 1.3.6.1.4.1.4756.20.730.20.1.543 | Columnf2000EASLoopProtectionPort3ActionStsLocal | read-only | current | f2000EAS Series card Loop Protection Status for Port 3: Action |
| 1.3.6.1.4.1.4756.20.730.20.1.544 | Columnf2000EASLoopProtectionPort3TransStsLocal | read-only | current | f2000EAS Series card Loop Protection Status for Port 3: Transmit |
| 1.3.6.1.4.1.4756.20.730.20.1.545 | Columnf2000EASLoopProtectionPort3LoopsStsLocal | read-only | current | f2000EAS Series card Loop Protection Status for Port 3: Loops |
| 1.3.6.1.4.1.4756.20.730.20.1.546 | Columnf2000EASLoopProtectionPort3StatusLocal | read-only | current | f2000EAS Series card Loop Protection Status for Port 3: Status |
| 1.3.6.1.4.1.4756.20.730.20.1.547 | Columnf2000EASLoopProtectionPort3LoopStsLocal | read-only | current | f2000EAS Series card Loop Protection Status for Port 3: Loop |
| 1.3.6.1.4.1.4756.20.730.20.1.548 | Columnf2000EASLoopProtectionPort4ActionStsLocal | read-only | current | f2000EAS Series card Loop Protection Status for Port 4: Action |
| 1.3.6.1.4.1.4756.20.730.20.1.549 | Columnf2000EASLoopProtectionPort4TransStsLocal | read-only | current | f2000EAS Series card Loop Protection Status for Port 4: Transmit |
| 1.3.6.1.4.1.4756.20.730.20.1.550 | Columnf2000EASLoopProtectionPort4LoopsStsLocal | read-only | current | f2000EAS Series card Loop Protection Status for Port 4: Loops |
| 1.3.6.1.4.1.4756.20.730.20.1.551 | Columnf2000EASLoopProtectionPort4StatusLocal | read-only | current | f2000EAS Series card Loop Protection Status for Port 4: Status |
| 1.3.6.1.4.1.4756.20.730.20.1.552 | Columnf2000EASLoopProtectionPort4LoopStsLocal | read-only | current | f2000EAS Series card Loop Protection Status for Port 4: Loop |
| 1.3.6.1.4.1.4756.20.730.20.1.553 | Columnf2000EASSTPProtocolVersionLocal | read-write | current | f2000EAS Series card STP Bridge Configuration: Basic Settings - Protocol Version 0: STP 1: RSTP 2: MSTP |
| 1.3.6.1.4.1.4756.20.730.20.1.554 | Columnf2000EASSTPBridgePriorityLocal | read-write | current | f2000EAS Series card STP Bridge Configuration: Basic Settings - Bridge Priority 0: 0 1: 4096 2: 8192 3: 12288 4: 16384 5: 20480 6: 24576 7: 28672 8: 32768 9: 3… |
| 1.3.6.1.4.1.4756.20.730.20.1.555 | Columnf2000EASSTPForwardDelayLocal | read-write | current | f2000EAS Series card STP Bridge Configuration: Basic Settings - Forward Delay |
| 1.3.6.1.4.1.4756.20.730.20.1.556 | Columnf2000EASSTPMaxAgeLocal | read-write | current | f2000EAS Series card STP Bridge Configuration: Basic Settings - Max Age |
| 1.3.6.1.4.1.4756.20.730.20.1.557 | Columnf2000EASSTPMaximumHopCountLocal | read-write | current | f2000EAS Series card STP Bridge Configuration: Basic Settings - Maximum Hop Count |
| 1.3.6.1.4.1.4756.20.730.20.1.558 | Columnf2000EASSTPTransmitHoldCountLocal | read-write | current | f2000EAS Series card STP Bridge Configuration: Basic Settings - Transmit Hold Count |
| 1.3.6.1.4.1.4756.20.730.20.1.559 | Columnf2000EASSTPEdgePortBPDUFilteringLocal | read-write | current | f2000EAS Series card STP Bridge Configuration: Advanced Settings - Edge Port BPDU Filtering 0: Off 1: On |
| 1.3.6.1.4.1.4756.20.730.20.1.560 | Columnf2000EASSTPEdgePortBPDUGuardLocal | read-write | current | f2000EAS Series card STP Bridge Configuration: Advanced Settings - Edge Port BPDU Guard 0: Off 1: On |
| 1.3.6.1.4.1.4756.20.730.20.1.561 | Columnf2000EASSTPPortErrorRecoveryTimeoutLocal | read-write | current | f2000EAS Series card STP Bridge Configuration: Advanced Settings - Port Error Recovery Timeout 0: Off 1: On |
| 1.3.6.1.4.1.4756.20.730.20.1.562 | Columnf2000EASMSTIConfigurationNameLocal | read-write | current | f2000EAS Series card MSTI Configuration: Configuration Identification - Configuration Name |
| 1.3.6.1.4.1.4756.20.730.20.1.563 | Columnf2000EASMSTIConfigurationRevisionLocal | read-write | current | f2000EAS Series card MSTI Configuration: Configuration Identification - Configuration Revision |
| 1.3.6.1.4.1.4756.20.730.20.1.564 | Columnf2000EASMSTI1VLANsMappingLocal | read-write | current | f2000EAS Series card MSTI Configuration: MSTI Mapping - MSTI 1 |
| 1.3.6.1.4.1.4756.20.730.20.1.565 | Columnf2000EASMSTI2VLANsMappingLocal | read-write | current | f2000EAS Series card MSTI Configuration: MSTI Mapping - MSTI 2 |
| 1.3.6.1.4.1.4756.20.730.20.1.566 | Columnf2000EASMSTI3VLANsMappingLocal | read-write | current | f2000EAS Series card MSTI Configuration: MSTI Mapping - MSTI 3 |
| 1.3.6.1.4.1.4756.20.730.20.1.567 | Columnf2000EASMSTI4VLANsMappingLocal | read-write | current | f2000EAS Series card MSTI Configuration: MSTI Mapping - MSTI 4 |
| 1.3.6.1.4.1.4756.20.730.20.1.568 | Columnf2000EASMSTI5VLANsMappingLocal | read-write | current | f2000EAS Series card MSTI Configuration: MSTI Mapping - MSTI 5 |
| 1.3.6.1.4.1.4756.20.730.20.1.569 | Columnf2000EASMSTI6VLANsMappingLocal | read-write | current | f2000EAS Series card MSTI Configuration: MSTI Mapping - MSTI 6 |
| 1.3.6.1.4.1.4756.20.730.20.1.570 | Columnf2000EASMSTI7VLANsMappingLocal | read-write | current | f2000EAS Series card MSTI Configuration: MSTI Mapping - MSTI 7 |
| 1.3.6.1.4.1.4756.20.730.20.1.571 | Columnf2000EASCISTAggregatedSTPEnabledLocal | read-write | current | f2000EAS Series card STP CIST Port Configuration: CIST Aggregated Port Configuration - STP Enabled |
| 1.3.6.1.4.1.4756.20.730.20.1.572 | Columnf2000EASCISTAggregatedPathCostLocal | read-write | current | f2000EAS Series card STP CIST Port Configuration: CIST Aggregated Port Configuration - Path Cost Valid values are in the range 0 to 200000000. Setting 0 means … |
| 1.3.6.1.4.1.4756.20.730.20.1.573 | Columnf2000EASCISTAggregatedPriorityLocal | read-write | current | f2000EAS Series card STP CIST Port Configuration: CIST Aggregated Port Configuration - Priority |
| 1.3.6.1.4.1.4756.20.730.20.1.574 | Columnf2000EASCISTAggregatedAdminEdgeLocal | read-write | current | f2000EAS Series card STP CIST Port Configuration: CIST Aggregated Port Configuration - STP Enabled 0: Non-edge 1: Edge |
| 1.3.6.1.4.1.4756.20.730.20.1.575 | Columnf2000EASCISTAggregatedAutoEdgeLocal | read-write | current | f2000EAS Series card STP CIST Port Configuration: CIST Aggregated Port Configuration - Auto Edge 0: Non-edge 1: Edge |
| 1.3.6.1.4.1.4756.20.730.20.1.576 | Columnf2000EASCISTAggregatedRestrictedRoleLocal | read-write | current | f2000EAS Series card STP CIST Port Configuration: CIST Aggregated Port Configuration - Restricted Role 0: Non-edge 1: Edge |
| 1.3.6.1.4.1.4756.20.730.20.1.577 | Columnf2000EASCISTAggregatedRestrictedTCNLocal | read-write | current | f2000EAS Series card STP CIST Port Configuration: CIST Aggregated Port Configuration - Restricted TCN 0: Non-edge 1: Edge |
| 1.3.6.1.4.1.4756.20.730.20.1.578 | Columnf2000EASCISTAggregatedBPDUGuardLocal | read-write | current | f2000EAS Series card STP CIST Port Configuration: CIST Aggregated Port Configuration - BPDU Guard 0: Non-edge 1: Edge |
| 1.3.6.1.4.1.4756.20.730.20.1.579 | Columnf2000EASCISTAggregatedPointToPointLocal | read-write | current | f2000EAS Series card STP CIST Port Configuration: CIST Aggregated Port Configuration - Point-to-point 0: Forced True 1: Forced False 2: Auto |
| 1.3.6.1.4.1.4756.20.730.20.1.580 | Columnf2000EASCISTPort1STPEnabledLocal | read-write | current | f2000EAS Series card STP CIST Port Configuration: CIST Normal Port1 Configuration - STP Enabled |
| 1.3.6.1.4.1.4756.20.730.20.1.581 | Columnf2000EASCISTPort1PathCostLocal | read-write | current | f2000EAS Series card STP CIST Port Configuration: CIST Normal Port1 Configuration - Path Cost Valid values are in the range 0 to 200000000. Setting 0 means Aut… |
| 1.3.6.1.4.1.4756.20.730.20.1.582 | Columnf2000EASCISTPort1PriorityLocal | read-write | current | f2000EAS Series card STP CIST Port Configuration: CIST Normal Port1 Configuration - Priority |
| 1.3.6.1.4.1.4756.20.730.20.1.583 | Columnf2000EASCISTPort1AdminEdgeLocal | read-write | current | f2000EAS Series card STP CIST Port Configuration: CIST Normal Port1 Configuration - STP Enabled 0: Non-edge 1: Edge |
| 1.3.6.1.4.1.4756.20.730.20.1.584 | Columnf2000EASCISTPort1AutoEdgeLocal | read-write | current | f2000EAS Series card STP CIST Port Configuration: CIST Normal Port1 Configuration - Auto Edge 0: Non-edge 1: Edge |
| 1.3.6.1.4.1.4756.20.730.20.1.585 | Columnf2000EASCISTPort1RestrictedRoleLocal | read-write | current | f2000EAS Series card STP CIST Port Configuration: CIST Normal Port1 Configuration - Restricted Role 0: Non-edge 1: Edge |
| 1.3.6.1.4.1.4756.20.730.20.1.586 | Columnf2000EASCISTPort1RestrictedTCNLocal | read-write | current | f2000EAS Series card STP CIST Port Configuration: CIST Normal Port1 Configuration - Restricted TCN 0: Non-edge 1: Edge |
| 1.3.6.1.4.1.4756.20.730.20.1.587 | Columnf2000EASCISTPort1BPDUGuardLocal | read-write | current | f2000EAS Series card STP CIST Port Configuration: CIST Normal Port1 Configuration - BPDU Guard 0: Non-edge 1: Edge |
| 1.3.6.1.4.1.4756.20.730.20.1.588 | Columnf2000EASCISTPort1PointToPointLocal | read-write | current | f2000EAS Series card STP CIST Port Configuration: CIST Normal Port1 Configuration - Point-to-point 0: Forced True 1: Forced False 2: Auto |
| 1.3.6.1.4.1.4756.20.730.20.1.589 | Columnf2000EASCISTPort2STPEnabledLocal | read-write | current | f2000EAS Series card STP CIST Port Configuration: CIST Normal Port2 Configuration - STP Enabled |
| 1.3.6.1.4.1.4756.20.730.20.1.590 | Columnf2000EASCISTPort2PathCostLocal | read-write | current | f2000EAS Series card STP CIST Port Configuration: CIST Normal Port2 Configuration - Path Cost Valid values are in the range 0 to 200000000. Setting 0 means Aut… |
| 1.3.6.1.4.1.4756.20.730.20.1.591 | Columnf2000EASCISTPort2PriorityLocal | read-write | current | f2000EAS Series card STP CIST Port Configuration: CIST Normal Port2 Configuration - Priority |
| 1.3.6.1.4.1.4756.20.730.20.1.592 | Columnf2000EASCISTPort2AdminEdgeLocal | read-write | current | f2000EAS Series card STP CIST Port Configuration: CIST Normal Port2 Configuration - STP Enabled 0: Non-edge 1: Edge |
| 1.3.6.1.4.1.4756.20.730.20.1.593 | Columnf2000EASCISTPort2AutoEdgeLocal | read-write | current | f2000EAS Series card STP CIST Port Configuration: CIST Normal Port2 Configuration - Auto Edge 0: Non-edge 1: Edge |
| 1.3.6.1.4.1.4756.20.730.20.1.594 | Columnf2000EASCISTPort2RestrictedRoleLocal | read-write | current | f2000EAS Series card STP CIST Port Configuration: CIST Normal Port2 Configuration - Restricted Role 0: Non-edge 1: Edge |
| 1.3.6.1.4.1.4756.20.730.20.1.595 | Columnf2000EASCISTPort2RestrictedTCNLocal | read-write | current | f2000EAS Series card STP CIST Port Configuration: CIST Normal Port2 Configuration - Restricted TCN 0: Non-edge 1: Edge |
| 1.3.6.1.4.1.4756.20.730.20.1.596 | Columnf2000EASCISTPort2BPDUGuardLocal | read-write | current | f2000EAS Series card STP CIST Port Configuration: CIST Normal Port2 Configuration - BPDU Guard 0: Non-edge 1: Edge |
| 1.3.6.1.4.1.4756.20.730.20.1.597 | Columnf2000EASCISTPort2PointToPointLocal | read-write | current | f2000EAS Series card STP CIST Port Configuration: CIST Normal Port2 Configuration - Point-to-point 0: Forced True 1: Forced False 2: Auto |
| 1.3.6.1.4.1.4756.20.730.20.1.598 | Columnf2000EASCISTPort3STPEnabledLocal | read-write | current | f2000EAS Series card STP CIST Port Configuration: CIST Normal Port3 Configuration - STP Enabled |
| 1.3.6.1.4.1.4756.20.730.20.1.599 | Columnf2000EASCISTPort3PathCostLocal | read-write | current | f2000EAS Series card STP CIST Port Configuration: CIST Normal Port3 Configuration - Path Cost Valid values are in the range 0 to 200000000. Setting 0 means Aut… |
| 1.3.6.1.4.1.4756.20.730.20.1.600 | Columnf2000EASCISTPort3PriorityLocal | read-write | current | f2000EAS Series card STP CIST Port Configuration: CIST Normal Port3 Configuration - Priority |
| 1.3.6.1.4.1.4756.20.730.20.1.601 | Columnf2000EASCISTPort3AdminEdgeLocal | read-write | current | f2000EAS Series card STP CIST Port Configuration: CIST Normal Port3 Configuration - STP Enabled 0: Non-edge 1: Edge |
| 1.3.6.1.4.1.4756.20.730.20.1.602 | Columnf2000EASCISTPort3AutoEdgeLocal | read-write | current | f2000EAS Series card STP CIST Port Configuration: CIST Normal Port3 Configuration - Auto Edge 0: Non-edge 1: Edge |
| 1.3.6.1.4.1.4756.20.730.20.1.603 | Columnf2000EASCISTPort3RestrictedRoleLocal | read-write | current | f2000EAS Series card STP CIST Port Configuration: CIST Normal Port3 Configuration - Restricted Role 0: Non-edge 1: Edge |
| 1.3.6.1.4.1.4756.20.730.20.1.604 | Columnf2000EASCISTPort3RestrictedTCNLocal | read-write | current | f2000EAS Series card STP CIST Port Configuration: CIST Normal Port3 Configuration - Restricted TCN 0: Non-edge 1: Edge |
| 1.3.6.1.4.1.4756.20.730.20.1.605 | Columnf2000EASCISTPort3BPDUGuardLocal | read-write | current | f2000EAS Series card STP CIST Port Configuration: CIST Normal Port3 Configuration - BPDU Guard 0: Non-edge 1: Edge |
| 1.3.6.1.4.1.4756.20.730.20.1.606 | Columnf2000EASCISTPort3PointToPointLocal | read-write | current | f2000EAS Series card STP CIST Port Configuration: CIST Normal Port3 Configuration - Point-to-point 0: Forced True 1: Forced False 2: Auto |
| 1.3.6.1.4.1.4756.20.730.20.1.607 | Columnf2000EASCISTPort4STPEnabledLocal | read-write | current | f2000EAS Series card STP CIST Port Configuration: CIST Normal Port4 Configuration - STP Enabled |
| 1.3.6.1.4.1.4756.20.730.20.1.608 | Columnf2000EASCISTPort4PathCostLocal | read-write | current | f2000EAS Series card STP CIST Port Configuration: CIST Normal Port4 Configuration - Path Cost Valid values are in the range 0 to 200000000. Setting 0 means Aut… |
| 1.3.6.1.4.1.4756.20.730.20.1.609 | Columnf2000EASCISTPort4PriorityLocal | read-write | current | f2000EAS Series card STP CIST Port Configuration: CIST Normal Port4 Configuration - Priority |
| 1.3.6.1.4.1.4756.20.730.20.1.610 | Columnf2000EASCISTPort4AdminEdgeLocal | read-write | current | f2000EAS Series card STP CIST Port Configuration: CIST Normal Port4 Configuration - STP Enabled 0: Non-edge 1: Edge |
| 1.3.6.1.4.1.4756.20.730.20.1.611 | Columnf2000EASCISTPort4AutoEdgeLocal | read-write | current | f2000EAS Series card STP CIST Port Configuration: CIST Normal Port4 Configuration - Auto Edge 0: Non-edge 1: Edge |
| 1.3.6.1.4.1.4756.20.730.20.1.612 | Columnf2000EASCISTPort4RestrictedRoleLocal | read-write | current | f2000EAS Series card STP CIST Port Configuration: CIST Normal Port4 Configuration - Restricted Role 0: Non-edge 1: Edge |
| 1.3.6.1.4.1.4756.20.730.20.1.613 | Columnf2000EASCISTPort4RestrictedTCNLocal | read-write | current | f2000EAS Series card STP CIST Port Configuration: CIST Normal Port4 Configuration - Restricted TCN 0: Non-edge 1: Edge |
| 1.3.6.1.4.1.4756.20.730.20.1.614 | Columnf2000EASCISTPort4BPDUGuardLocal | read-write | current | f2000EAS Series card STP CIST Port Configuration: CIST Normal Port4 Configuration - BPDU Guard 0: Non-edge 1: Edge |
| 1.3.6.1.4.1.4756.20.730.20.1.615 | Columnf2000EASCISTPort4PointToPointLocal | read-write | current | f2000EAS Series card STP CIST Port Configuration: CIST Normal Port4 Configuration - Point-to-point 0: Forced True 1: Forced False 2: Auto |
| 1.3.6.1.4.1.4756.20.730.20.1.616 | Columnf2000EASMSTI1AggregatedPathCostLocal | read-write | current | f2000EAS Series card MSTI Port Configuration: MSTI1 Aggregated Ports Configuration - Path Cost Valid values are in the range 0 to 200000000. Setting 0 means Au… |
| 1.3.6.1.4.1.4756.20.730.20.1.617 | Columnf2000EASMSTI1AggregatedPriorityLocal | read-write | current | f2000EAS Series card MSTI Port Configuration: MSTI1 Aggregated Ports Configuration - Priority |
| 1.3.6.1.4.1.4756.20.730.20.1.618 | Columnf2000EASMSTI1Port1PathCostLocal | read-write | current | f2000EAS Series card MSTI Port Configuration: MSTI1 Normal Port1 Configuration - Path Cost Valid values are in the range 0 to 200000000. Setting 0 means Auto p… |
| 1.3.6.1.4.1.4756.20.730.20.1.619 | Columnf2000EASMSTI1Port1PriorityLocal | read-write | current | f2000EAS Series card MSTI Port Configuration: MSTI1 Normal Port1 Configuration - Priority |
| 1.3.6.1.4.1.4756.20.730.20.1.620 | Columnf2000EASMSTI1Port2PathCostLocal | read-write | current | f2000EAS Series card MSTI Port Configuration: MSTI1 Normal Port2 Configuration - Path Cost Valid values are in the range 0 to 200000000. Setting 0 means Auto p… |
| 1.3.6.1.4.1.4756.20.730.20.1.621 | Columnf2000EASMSTI1Port2PriorityLocal | read-write | current | f2000EAS Series card MSTI Port Configuration: MSTI1 Normal Port2 Configuration - Priority |
| 1.3.6.1.4.1.4756.20.730.20.1.622 | Columnf2000EASMSTI1Port3PathCostLocal | read-write | current | f2000EAS Series card MSTI Port Configuration: MSTI1 Normal Port3 Configuration - Path Cost Valid values are in the range 0 to 200000000. Setting 0 means Auto p… |
| 1.3.6.1.4.1.4756.20.730.20.1.623 | Columnf2000EASMSTI1Port3PriorityLocal | read-write | current | f2000EAS Series card MSTI Port Configuration: MSTI1 Normal Port3 Configuration - Priority |
| 1.3.6.1.4.1.4756.20.730.20.1.624 | Columnf2000EASMSTI1Port4PathCostLocal | read-write | current | f2000EAS Series card MSTI Port Configuration: MSTI1 Normal Port4 Configuration - Path Cost Valid values are in the range 0 to 200000000. Setting 0 means Auto p… |
| 1.3.6.1.4.1.4756.20.730.20.1.625 | Columnf2000EASMSTI1Port4PriorityLocal | read-write | current | f2000EAS Series card MSTI Port Configuration: MSTI1 Normal Port4 Configuration - Priority |
| 1.3.6.1.4.1.4756.20.730.20.1.626 | Columnf2000EASMSTI2AggregatedPathCostLocal | read-write | current | f2000EAS Series card MSTI Port Configuration: MSTI2 Aggregated Ports Configuration - Path Cost Valid values are in the range 0 to 200000000. Setting 0 means Au… |
| 1.3.6.1.4.1.4756.20.730.20.1.627 | Columnf2000EASMSTI2AggregatedPriorityLocal | read-write | current | f2000EAS Series card MSTI Port Configuration: MSTI2 Aggregated Ports Configuration - Priority |
| 1.3.6.1.4.1.4756.20.730.20.1.628 | Columnf2000EASMSTI2Port1PathCostLocal | read-write | current | f2000EAS Series card MSTI Port Configuration: MSTI2 Normal Port1 Configuration - Path Cost Valid values are in the range 0 to 200000000. Setting 0 means Auto p… |
| 1.3.6.1.4.1.4756.20.730.20.1.629 | Columnf2000EASMSTI2Port1PriorityLocal | read-write | current | f2000EAS Series card MSTI Port Configuration: MSTI2 Normal Port1 Configuration - Priority |
| 1.3.6.1.4.1.4756.20.730.20.1.630 | Columnf2000EASMSTI2Port2PathCostLocal | read-write | current | f2000EAS Series card MSTI Port Configuration: MSTI2 Normal Port2 Configuration - Path Cost Valid values are in the range 0 to 200000000. Setting 0 means Auto p… |
| 1.3.6.1.4.1.4756.20.730.20.1.631 | Columnf2000EASMSTI2Port2PriorityLocal | read-write | current | f2000EAS Series card MSTI Port Configuration: MSTI2 Normal Port2 Configuration - Priority |
| 1.3.6.1.4.1.4756.20.730.20.1.632 | Columnf2000EASMSTI2Port3PathCostLocal | read-write | current | f2000EAS Series card MSTI Port Configuration: MSTI2 Normal Port3 Configuration - Path Cost Valid values are in the range 0 to 200000000. Setting 0 means Auto p… |
| 1.3.6.1.4.1.4756.20.730.20.1.633 | Columnf2000EASMSTI2Port3PriorityLocal | read-write | current | f2000EAS Series card MSTI Port Configuration: MSTI2 Normal Port3 Configuration - Priority |
| 1.3.6.1.4.1.4756.20.730.20.1.634 | Columnf2000EASMSTI2Port4PathCostLocal | read-write | current | f2000EAS Series card MSTI Port Configuration: MSTI2 Normal Port4 Configuration - Path Cost Valid values are in the range 0 to 200000000. Setting 0 means Auto p… |
| 1.3.6.1.4.1.4756.20.730.20.1.635 | Columnf2000EASMSTI2Port4PriorityLocal | read-write | current | f2000EAS Series card MSTI Port Configuration: MSTI2 Normal Port4 Configuration - Priority |
| 1.3.6.1.4.1.4756.20.730.20.1.636 | Columnf2000EASMSTI3AggregatedPathCostLocal | read-write | current | f2000EAS Series card MSTI Port Configuration: MSTI3 Aggregated Ports Configuration - Path Cost Valid values are in the range 0 to 200000000. Setting 0 means Au… |
| 1.3.6.1.4.1.4756.20.730.20.1.637 | Columnf2000EASMSTI3AggregatedPriorityLocal | read-write | current | f2000EAS Series card MSTI Port Configuration: MSTI3 Aggregated Ports Configuration - Priority |
| 1.3.6.1.4.1.4756.20.730.20.1.638 | Columnf2000EASMSTI3Port1PathCostLocal | read-write | current | f2000EAS Series card MSTI Port Configuration: MSTI3 Normal Port1 Configuration - Path Cost Valid values are in the range 0 to 200000000. Setting 0 means Auto p… |
| 1.3.6.1.4.1.4756.20.730.20.1.639 | Columnf2000EASMSTI3Port1PriorityLocal | read-write | current | f2000EAS Series card MSTI Port Configuration: MSTI3 Normal Port1 Configuration - Priority |
| 1.3.6.1.4.1.4756.20.730.20.1.640 | Columnf2000EASMSTI3Port2PathCostLocal | read-write | current | f2000EAS Series card MSTI Port Configuration: MSTI3 Normal Port2 Configuration - Path Cost Valid values are in the range 0 to 200000000. Setting 0 means Auto p… |
| 1.3.6.1.4.1.4756.20.730.20.1.641 | Columnf2000EASMSTI3Port2PriorityLocal | read-write | current | f2000EAS Series card MSTI Port Configuration: MSTI3 Normal Port2 Configuration - Priority |
| 1.3.6.1.4.1.4756.20.730.20.1.642 | Columnf2000EASMSTI3Port3PathCostLocal | read-write | current | f2000EAS Series card MSTI Port Configuration: MSTI1 Normal Port3 Configuration - Path Cost Valid values are in the range 0 to 200000000. Setting 0 means Auto p… |
| 1.3.6.1.4.1.4756.20.730.20.1.643 | Columnf2000EASMSTI3Port3PriorityLocal | read-write | current | f2000EAS Series card MSTI Port Configuration: MSTI3 Normal Port3 Configuration - Priority |
| 1.3.6.1.4.1.4756.20.730.20.1.644 | Columnf2000EASMSTI3Port4PathCostLocal | read-write | current | f2000EAS Series card MSTI Port Configuration: MSTI3 Normal Port4 Configuration - Path Cost Valid values are in the range 0 to 200000000. Setting 0 means Auto p… |
| 1.3.6.1.4.1.4756.20.730.20.1.645 | Columnf2000EASMSTI3Port4PriorityLocal | read-write | current | f2000EAS Series card MSTI Port Configuration: MSTI3 Normal Port4 Configuration - Priority |
| 1.3.6.1.4.1.4756.20.730.20.1.646 | Columnf2000EASMSTI4AggregatedPathCostLocal | read-write | current | f2000EAS Series card MSTI Port Configuration: MSTI4 Aggregated Ports Configuration - Path Cost Valid values are in the range 0 to 200000000. Setting 0 means Au… |
| 1.3.6.1.4.1.4756.20.730.20.1.647 | Columnf2000EASMSTI4AggregatedPriorityLocal | read-write | current | f2000EAS Series card MSTI Port Configuration: MSTI4 Aggregated Ports Configuration - Priority |
| 1.3.6.1.4.1.4756.20.730.20.1.648 | Columnf2000EASMSTI4Port1PathCostLocal | read-write | current | f2000EAS Series card MSTI Port Configuration: MSTI4 Normal Port1 Configuration - Path Cost Valid values are in the range 0 to 200000000. Setting 0 means Auto p… |
| 1.3.6.1.4.1.4756.20.730.20.1.649 | Columnf2000EASMSTI4Port1PriorityLocal | read-write | current | f2000EAS Series card MSTI Port Configuration: MSTI4 Normal Port1 Configuration - Priority |
| 1.3.6.1.4.1.4756.20.730.20.1.650 | Columnf2000EASMSTI4Port2PathCostLocal | read-write | current | f2000EAS Series card MSTI Port Configuration: MSTI4 Normal Port2 Configuration - Path Cost Valid values are in the range 0 to 200000000. Setting 0 means Auto p… |
| 1.3.6.1.4.1.4756.20.730.20.1.651 | Columnf2000EASMSTI4Port2PriorityLocal | read-write | current | f2000EAS Series card MSTI Port Configuration: MSTI4 Normal Port2 Configuration - Priority |
| 1.3.6.1.4.1.4756.20.730.20.1.652 | Columnf2000EASMSTI4Port3PathCostLocal | read-write | current | f2000EAS Series card MSTI Port Configuration: MSTI1 Normal Port3 Configuration - Path Cost Valid values are in the range 0 to 200000000. Setting 0 means Auto p… |
| 1.3.6.1.4.1.4756.20.730.20.1.653 | Columnf2000EASMSTI4Port3PriorityLocal | read-write | current | f2000EAS Series card MSTI Port Configuration: MSTI4 Normal Port3 Configuration - Priority |
| 1.3.6.1.4.1.4756.20.730.20.1.654 | Columnf2000EASMSTI4Port4PathCostLocal | read-write | current | f2000EAS Series card MSTI Port Configuration: MSTI4 Normal Port4 Configuration - Path Cost Valid values are in the range 0 to 200000000. Setting 0 means Auto p… |
| 1.3.6.1.4.1.4756.20.730.20.1.655 | Columnf2000EASMSTI4Port4PriorityLocal | read-write | current | f2000EAS Series card MSTI Port Configuration: MSTI4 Normal Port4 Configuration - Priority |
| 1.3.6.1.4.1.4756.20.730.20.1.656 | Columnf2000EASMSTI5AggregatedPathCostLocal | read-write | current | f2000EAS Series card MSTI Port Configuration: MSTI5 Aggregated Ports Configuration - Path Cost Valid values are in the range 0 to 200000000. Setting 0 means Au… |
| 1.3.6.1.4.1.4756.20.730.20.1.657 | Columnf2000EASMSTI5AggregatedPriorityLocal | read-write | current | f2000EAS Series card MSTI Port Configuration: MSTI5 Aggregated Ports Configuration - Priority |
| 1.3.6.1.4.1.4756.20.730.20.1.658 | Columnf2000EASMSTI5Port1PathCostLocal | read-write | current | f2000EAS Series card MSTI Port Configuration: MSTI5 Normal Port1 Configuration - Path Cost Valid values are in the range 0 to 200000000. Setting 0 means Auto p… |
| 1.3.6.1.4.1.4756.20.730.20.1.659 | Columnf2000EASMSTI5Port1PriorityLocal | read-write | current | f2000EAS Series card MSTI Port Configuration: MSTI5 Normal Port1 Configuration - Priority |
| 1.3.6.1.4.1.4756.20.730.20.1.660 | Columnf2000EASMSTI5Port2PathCostLocal | read-write | current | f2000EAS Series card MSTI Port Configuration: MSTI5 Normal Port2 Configuration - Path Cost Valid values are in the range 0 to 200000000. Setting 0 means Auto p… |
| 1.3.6.1.4.1.4756.20.730.20.1.661 | Columnf2000EASMSTI5Port2PriorityLocal | read-write | current | f2000EAS Series card MSTI Port Configuration: MSTI5 Normal Port2 Configuration - Priority |
| 1.3.6.1.4.1.4756.20.730.20.1.662 | Columnf2000EASMSTI5Port3PathCostLocal | read-write | current | f2000EAS Series card MSTI Port Configuration: MSTI5 Normal Port3 Configuration - Path Cost Valid values are in the range 0 to 200000000. Setting 0 means Auto p… |
| 1.3.6.1.4.1.4756.20.730.20.1.663 | Columnf2000EASMSTI5Port3PriorityLocal | read-write | current | f2000EAS Series card MSTI Port Configuration: MSTI5 Normal Port3 Configuration - Priority |
| 1.3.6.1.4.1.4756.20.730.20.1.664 | Columnf2000EASMSTI5Port4PathCostLocal | read-write | current | f2000EAS Series card MSTI Port Configuration: MSTI5 Normal Port4 Configuration - Path Cost Valid values are in the range 0 to 200000000. Setting 0 means Auto p… |
| 1.3.6.1.4.1.4756.20.730.20.1.665 | Columnf2000EASMSTI5Port4PriorityLocal | read-write | current | f2000EAS Series card MSTI Port Configuration: MSTI5 Normal Port4 Configuration - Priority |
| 1.3.6.1.4.1.4756.20.730.20.1.666 | Columnf2000EASMSTI6AggregatedPathCostLocal | read-write | current | f2000EAS Series card MSTI Port Configuration: MSTI6 Aggregated Ports Configuration - Path Cost Valid values are in the range 0 to 200000000. Setting 0 means Au… |
| 1.3.6.1.4.1.4756.20.730.20.1.667 | Columnf2000EASMSTI6AggregatedPriorityLocal | read-write | current | f2000EAS Series card MSTI Port Configuration: MSTI6 Aggregated Ports Configuration - Priority |
| 1.3.6.1.4.1.4756.20.730.20.1.668 | Columnf2000EASMSTI6Port1PathCostLocal | read-write | current | f2000EAS Series card MSTI Port Configuration: MSTI6 Normal Port1 Configuration - Path Cost Valid values are in the range 0 to 200000000. Setting 0 means Auto p… |
| 1.3.6.1.4.1.4756.20.730.20.1.669 | Columnf2000EASMSTI6Port1PriorityLocal | read-write | current | f2000EAS Series card MSTI Port Configuration: MSTI6 Normal Port1 Configuration - Priority |
| 1.3.6.1.4.1.4756.20.730.20.1.670 | Columnf2000EASMSTI6Port2PathCostLocal | read-write | current | f2000EAS Series card MSTI Port Configuration: MSTI6 Normal Port2 Configuration - Path Cost Valid values are in the range 0 to 200000000. Setting 0 means Auto p… |
| 1.3.6.1.4.1.4756.20.730.20.1.671 | Columnf2000EASMSTI6Port2PriorityLocal | read-write | current | f2000EAS Series card MSTI Port Configuration: MSTI6 Normal Port2 Configuration - Priority |
| 1.3.6.1.4.1.4756.20.730.20.1.672 | Columnf2000EASMSTI6Port3PathCostLocal | read-write | current | f2000EAS Series card MSTI Port Configuration: MSTI6 Normal Port3 Configuration - Path Cost Valid values are in the range 0 to 200000000. Setting 0 means Auto p… |
| 1.3.6.1.4.1.4756.20.730.20.1.673 | Columnf2000EASMSTI6Port3PriorityLocal | read-write | current | f2000EAS Series card MSTI Port Configuration: MSTI6 Normal Port3 Configuration - Priority |
| 1.3.6.1.4.1.4756.20.730.20.1.674 | Columnf2000EASMSTI6Port4PathCostLocal | read-write | current | f2000EAS Series card MSTI Port Configuration: MSTI6 Normal Port4 Configuration - Path Cost Valid values are in the range 0 to 200000000. Setting 0 means Auto p… |
| 1.3.6.1.4.1.4756.20.730.20.1.675 | Columnf2000EASMSTI6Port4PriorityLocal | read-write | current | f2000EAS Series card MSTI Port Configuration: MSTI6 Normal Port4 Configuration - Priority |
| 1.3.6.1.4.1.4756.20.730.20.1.676 | Columnf2000EASMSTI7AggregatedPathCostLocal | read-write | current | f2000EAS Series card MSTI Port Configuration: MSTI7 Aggregated Ports Configuration - Path Cost Valid values are in the range 0 to 200000000. Setting 0 means Au… |
| 1.3.6.1.4.1.4756.20.730.20.1.677 | Columnf2000EASMSTI7AggregatedPriorityLocal | read-write | current | f2000EAS Series card MSTI Port Configuration: MSTI7 Aggregated Ports Configuration - Priority |
| 1.3.6.1.4.1.4756.20.730.20.1.678 | Columnf2000EASMSTI7Port1PathCostLocal | read-write | current | f2000EAS Series card MSTI Port Configuration: MSTI1 Normal Port1 Configuration - Path Cost Valid values are in the range 0 to 200000000. Setting 0 means Auto p… |
| 1.3.6.1.4.1.4756.20.730.20.1.679 | Columnf2000EASMSTI7Port1PriorityLocal | read-write | current | f2000EAS Series card MSTI Port Configuration: MSTI1 Normal Port7 Configuration - Priority |
| 1.3.6.1.4.1.4756.20.730.20.1.680 | Columnf2000EASMSTI7Port2PathCostLocal | read-write | current | f2000EAS Series card MSTI Port Configuration: MSTI7 Normal Port2 Configuration - Path Cost Valid values are in the range 0 to 200000000. Setting 0 means Auto p… |
| 1.3.6.1.4.1.4756.20.730.20.1.681 | Columnf2000EASMSTI7Port2PriorityLocal | read-write | current | f2000EAS Series card MSTI Port Configuration: MSTI7 Normal Port2 Configuration - Priority |
| 1.3.6.1.4.1.4756.20.730.20.1.682 | Columnf2000EASMSTI7Port3PathCostLocal | read-write | current | f2000EAS Series card MSTI Port Configuration: MSTI7 Normal Port3 Configuration - Path Cost Valid values are in the range 0 to 200000000. Setting 0 means Auto p… |
| 1.3.6.1.4.1.4756.20.730.20.1.683 | Columnf2000EASMSTI7Port3PriorityLocal | read-write | current | f2000EAS Series card MSTI Port Configuration: MSTI7 Normal Port3 Configuration - Priority |
| 1.3.6.1.4.1.4756.20.730.20.1.684 | Columnf2000EASMSTI7Port4PathCostLocal | read-write | current | f2000EAS Series card MSTI Port Configuration: MSTI7 Normal Port4 Configuration - Path Cost Valid values are in the range 0 to 200000000. Setting 0 means Auto p… |
| 1.3.6.1.4.1.4756.20.730.20.1.685 | Columnf2000EASMSTI7Port4PriorityLocal | read-write | current | f2000EAS Series card MSTI Port Configuration: MSTI7 Normal Port4 Configuration - Priority |
| 1.3.6.1.4.1.4756.20.730.20.1.686 | Columnf2000EASCISTBridgeIDLocal | read-only | current | f2000EAS Series card STP Bridges status: CIST - Bridge ID |
| 1.3.6.1.4.1.4756.20.730.20.1.687 | Columnf2000EASCISTRootIDLocal | read-only | current | f2000EAS Series card STP Bridges status: CIST - Root ID |
| 1.3.6.1.4.1.4756.20.730.20.1.688 | Columnf2000EASCISTRootPortLocal | read-only | current | f2000EAS Series card STP Bridges status: CIST - Root Port |
| 1.3.6.1.4.1.4756.20.730.20.1.689 | Columnf2000EASCISTRootCostLocal | read-only | current | f2000EAS Series card STP Bridges status: CIST - Root Cost |
| 1.3.6.1.4.1.4756.20.730.20.1.690 | Columnf2000EASCISTTopologyFlagLocal | read-only | current | f2000EAS Series card STP Bridges status: CIST - Topology Flag |
| 1.3.6.1.4.1.4756.20.730.20.1.691 | Columnf2000EASCISTTopologyChangeLastLocal | read-only | current | f2000EAS Series card STP Bridges status: CIST - Topology Change Last |
| 1.3.6.1.4.1.4756.20.730.20.1.692 | Columnf2000EASMSTI1BridgeIDLocal | read-only | current | f2000EAS Series card STP Bridges status: MSTI1 - Bridge ID |
| 1.3.6.1.4.1.4756.20.730.20.1.693 | Columnf2000EASMSTI1RootIDLocal | read-only | current | f2000EAS Series card STP Bridges status: MSTI1 - Root ID |
| 1.3.6.1.4.1.4756.20.730.20.1.694 | Columnf2000EASMSTI1RootPortLocal | read-only | current | f2000EAS Series card STP Bridges status: MSTI1 - Root ID |
| 1.3.6.1.4.1.4756.20.730.20.1.695 | Columnf2000EASMSTI1RootCostLocal | read-only | current | f2000EAS Series card STP Bridges status: MSTI1 - Root Cost |
| 1.3.6.1.4.1.4756.20.730.20.1.696 | Columnf2000EASMSTI1TopologyFlagLocal | read-only | current | f2000EAS Series card STP Bridges status: MSTI1 - Topology Flag |
| 1.3.6.1.4.1.4756.20.730.20.1.697 | Columnf2000EASMSTI1TopologyChangeLastLocal | read-only | current | f2000EAS Series card STP Bridges status: MSTI1 - Topology Change Last |
| 1.3.6.1.4.1.4756.20.730.20.1.698 | Columnf2000EASMSTI2BridgeIDLocal | read-only | current | f2000EAS Series card STP Bridges status: MSTI2 - Bridge ID |
| 1.3.6.1.4.1.4756.20.730.20.1.699 | Columnf2000EASMSTI2RootIDLocal | read-only | current | f2000EAS Series card STP Bridges status: MSTI2 - Root ID |
| 1.3.6.1.4.1.4756.20.730.20.1.700 | Columnf2000EASMSTI2RootPortLocal | read-only | current | f2000EAS Series card STP Bridges status: MSTI2 - Root ID |
| 1.3.6.1.4.1.4756.20.730.20.1.701 | Columnf2000EASMSTI2RootCostLocal | read-only | current | f2000EAS Series card STP Bridges status: MSTI2 - Root Cost |
| 1.3.6.1.4.1.4756.20.730.20.1.702 | Columnf2000EASMSTI2TopologyFlagLocal | read-only | current | f2000EAS Series card STP Bridges status: MSTI2 - Topology Flag |
| 1.3.6.1.4.1.4756.20.730.20.1.703 | Columnf2000EASMSTI2TopologyChangeLastLocal | read-only | current | f2000EAS Series card STP Bridges status: MSTI2 - Topology Change Last |
| 1.3.6.1.4.1.4756.20.730.20.1.704 | Columnf2000EASMSTI3BridgeIDLocal | read-only | current | f2000EAS Series card STP Bridges status: MSTI3 - Bridge ID |
| 1.3.6.1.4.1.4756.20.730.20.1.705 | Columnf2000EASMSTI3RootIDLocal | read-only | current | f2000EAS Series card STP Bridges status: MSTI3 - Root ID |
| 1.3.6.1.4.1.4756.20.730.20.1.706 | Columnf2000EASMSTI3RootPortLocal | read-only | current | f2000EAS Series card STP Bridges status: MSTI3 - Root ID |
| 1.3.6.1.4.1.4756.20.730.20.1.707 | Columnf2000EASMSTI3RootCostLocal | read-only | current | f2000EAS Series card STP Bridges status: MSTI3 - Root Cost |
| 1.3.6.1.4.1.4756.20.730.20.1.708 | Columnf2000EASMSTI3TopologyFlagLocal | read-only | current | f2000EAS Series card STP Bridges status: MSTI3 - Topology Flag |
| 1.3.6.1.4.1.4756.20.730.20.1.709 | Columnf2000EASMSTI3TopologyChangeLastLocal | read-only | current | f2000EAS Series card STP Bridges status: MSTI3 - Topology Change Last |
| 1.3.6.1.4.1.4756.20.730.20.1.710 | Columnf2000EASMSTI4BridgeIDLocal | read-only | current | f2000EAS Series card STP Bridges status: MSTI4 - Bridge ID |
| 1.3.6.1.4.1.4756.20.730.20.1.711 | Columnf2000EASMSTI4RootIDLocal | read-only | current | f2000EAS Series card STP Bridges status: MSTI4 - Root ID |
| 1.3.6.1.4.1.4756.20.730.20.1.712 | Columnf2000EASMSTI4RootPortLocal | read-only | current | f2000EAS Series card STP Bridges status: MSTI4 - Root ID |
| 1.3.6.1.4.1.4756.20.730.20.1.713 | Columnf2000EASMSTI4RootCostLocal | read-only | current | f2000EAS Series card STP Bridges status: MSTI4 - Root Cost |
| 1.3.6.1.4.1.4756.20.730.20.1.714 | Columnf2000EASMSTI4TopologyFlagLocal | read-only | current | f2000EAS Series card STP Bridges status: MSTI4 - Topology Flag |
| 1.3.6.1.4.1.4756.20.730.20.1.715 | Columnf2000EASMSTI4TopologyChangeLastLocal | read-only | current | f2000EAS Series card STP Bridges status: MSTI4 - Topology Change Last |
| 1.3.6.1.4.1.4756.20.730.20.1.716 | Columnf2000EASMSTI5BridgeIDLocal | read-only | current | f2000EAS Series card STP Bridges status: MSTI5 - Bridge ID |
| 1.3.6.1.4.1.4756.20.730.20.1.717 | Columnf2000EASMSTI5RootIDLocal | read-only | current | f2000EAS Series card STP Bridges status: MSTI5 - Root ID |
| 1.3.6.1.4.1.4756.20.730.20.1.718 | Columnf2000EASMSTI5RootPortLocal | read-only | current | f2000EAS Series card STP Bridges status: MSTI5 - Root ID |
| 1.3.6.1.4.1.4756.20.730.20.1.719 | Columnf2000EASMSTI5RootCostLocal | read-only | current | f2000EAS Series card STP Bridges status: MSTI5 - Root Cost |
| 1.3.6.1.4.1.4756.20.730.20.1.720 | Columnf2000EASMSTI5TopologyFlagLocal | read-only | current | f2000EAS Series card STP Bridges status: MSTI5 - Topology Flag |
| 1.3.6.1.4.1.4756.20.730.20.1.721 | Columnf2000EASMSTI5TopologyChangeLastLocal | read-only | current | f2000EAS Series card STP Bridges status: MSTI5 - Topology Change Last |
| 1.3.6.1.4.1.4756.20.730.20.1.722 | Columnf2000EASMSTI6BridgeIDLocal | read-only | current | f2000EAS Series card STP Bridges status: MSTI6 - Bridge ID |
| 1.3.6.1.4.1.4756.20.730.20.1.723 | Columnf2000EASMSTI6RootIDLocal | read-only | current | f2000EAS Series card STP Bridges status: MSTI6 - Root ID |
| 1.3.6.1.4.1.4756.20.730.20.1.724 | Columnf2000EASMSTI6RootPortLocal | read-only | current | f2000EAS Series card STP Bridges status: MSTI6 - Root ID |
| 1.3.6.1.4.1.4756.20.730.20.1.725 | Columnf2000EASMSTI6RootCostLocal | read-only | current | f2000EAS Series card STP Bridges status: MSTI6 - Root Cost |
| 1.3.6.1.4.1.4756.20.730.20.1.726 | Columnf2000EASMSTI6TopologyFlagLocal | read-only | current | f2000EAS Series card STP Bridges status: MSTI6 - Topology Flag |
| 1.3.6.1.4.1.4756.20.730.20.1.727 | Columnf2000EASMSTI6TopologyChangeLastLocal | read-only | current | f2000EAS Series card STP Bridges status: MSTI6 - Topology Change Last |
| 1.3.6.1.4.1.4756.20.730.20.1.728 | Columnf2000EASMSTI7BridgeIDLocal | read-only | current | f2000EAS Series card STP Bridges status: MSTI7 - Bridge ID |
| 1.3.6.1.4.1.4756.20.730.20.1.729 | Columnf2000EASMSTI7RootIDLocal | read-only | current | f2000EAS Series card STP Bridges status: MSTI7 - Root ID |
| 1.3.6.1.4.1.4756.20.730.20.1.730 | Columnf2000EASMSTI7RootPortLocal | read-only | current | f2000EAS Series card STP Bridges status: MSTI7 - Root ID |
| 1.3.6.1.4.1.4756.20.730.20.1.731 | Columnf2000EASMSTI7RootCostLocal | read-only | current | f2000EAS Series card STP Bridges status: MSTI7 - Root Cost |
| 1.3.6.1.4.1.4756.20.730.20.1.732 | Columnf2000EASMSTI7TopologyFlagLocal | read-only | current | f2000EAS Series card STP Bridges status: MSTI7 - Topology Flag |
| 1.3.6.1.4.1.4756.20.730.20.1.733 | Columnf2000EASMSTI7TopologyChangeLastLocal | read-only | current | f2000EAS Series card STP Bridges status: MSTI7 - Topology Change Last |
| 1.3.6.1.4.1.4756.20.730.20.1.734 | Columnf2000EASSTPPortStatusInst1PortLocal | read-only | current | f2000EAS Series card STP Port status: Instance1 - Port |
| 1.3.6.1.4.1.4756.20.730.20.1.735 | Columnf2000EASSTPPortStatusInst1CISTRoleLocal | read-only | current | f2000EAS Series card STP Port status: Instance1 - CIST Role |
| 1.3.6.1.4.1.4756.20.730.20.1.736 | Columnf2000EASSTPPortStatusInst1CISTStateLocal | read-only | current | f2000EAS Series card STP Port status: Instance1 - CIST State |
| 1.3.6.1.4.1.4756.20.730.20.1.737 | Columnf2000EASSTPPortStatusInst1UptimeLocal | read-only | current | f2000EAS Series card STP Port status: Instance1 -Uptime |
| 1.3.6.1.4.1.4756.20.730.20.1.738 | Columnf2000EASSTPPortStatusInst2PortLocal | read-only | current | f2000EAS Series card STP Port status: Instance2 - Port |
| 1.3.6.1.4.1.4756.20.730.20.1.739 | Columnf2000EASSTPPortStatusInst2CISTRoleLocal | read-only | current | f2000EAS Series card STP Port status: Instance2 - CIST Role |
| 1.3.6.1.4.1.4756.20.730.20.1.740 | Columnf2000EASSTPPortStatusInst2CISTStateLocal | read-only | current | f2000EAS Series card STP Port status: Instance2 - CIST State |
| 1.3.6.1.4.1.4756.20.730.20.1.741 | Columnf2000EASSTPPortStatusInst2UptimeLocal | read-only | current | f2000EAS Series card STP Port status: Instance2 -Uptime |
| 1.3.6.1.4.1.4756.20.730.20.1.742 | Columnf2000EASSTPPortStatusInst3PortLocal | read-only | current | f2000EAS Series card STP Port status: Instance3 - Port |
| 1.3.6.1.4.1.4756.20.730.20.1.743 | Columnf2000EASSTPPortStatusInst3CISTRoleLocal | read-only | current | f2000EAS Series card STP Port status: Instance3 - CIST Role |
| 1.3.6.1.4.1.4756.20.730.20.1.744 | Columnf2000EASSTPPortStatusInst3CISTStateLocal | read-only | current | f2000EAS Series card STP Port status: Instance3 - CIST State |
| 1.3.6.1.4.1.4756.20.730.20.1.745 | Columnf2000EASSTPPortStatusInst3UptimeLocal | read-only | current | f2000EAS Series card STP Port status: Instance3 -Uptime |
| 1.3.6.1.4.1.4756.20.730.20.1.746 | Columnf2000EASSTPPortStatusInst4PortLocal | read-only | current | f2000EAS Series card STP Port status: Instance4 - Port |
| 1.3.6.1.4.1.4756.20.730.20.1.747 | Columnf2000EASSTPPortStatusInst4CISTRoleLocal | read-only | current | f2000EAS Series card STP Port status: Instance4 - CIST Role |
| 1.3.6.1.4.1.4756.20.730.20.1.748 | Columnf2000EASSTPPortStatusInst4CISTStateLocal | read-only | current | f2000EAS Series card STP Port status: Instance4 - CIST State |
| 1.3.6.1.4.1.4756.20.730.20.1.749 | Columnf2000EASSTPPortStatusInst4UptimeLocal | read-only | current | f2000EAS Series card STP Port status: Instance4 -Uptime |
| 1.3.6.1.4.1.4756.20.730.20.1.750 | Columnf2000EASSTPStatisticsPort1TxMSTPLocal | read-only | current | f2000EAS Series card STP Port Statistics: Port1 -Transmitted MSTP |
| 1.3.6.1.4.1.4756.20.730.20.1.751 | Columnf2000EASSTPStatisticsPort1TxRSTPLocal | read-only | current | f2000EAS Series card STP Port Statistics: Port1 -Transmitted RSTP |
| 1.3.6.1.4.1.4756.20.730.20.1.752 | Columnf2000EASSTPStatisticsPort1TxSTPLocal | read-only | current | f2000EAS Series card STP Port Statistics: Port1 -Transmitted RSTP |
| 1.3.6.1.4.1.4756.20.730.20.1.753 | Columnf2000EASSTPStatisticsPort1TxTCNLocal | read-only | current | f2000EAS Series card STP Port Statistics: Port1 -Transmitted RSTP |
| 1.3.6.1.4.1.4756.20.730.20.1.754 | Columnf2000EASSTPStatisticsPort1RxMSTPLocal | read-only | current | f2000EAS Series card STP Port Statistics: Port1 -Received MSTP |
| 1.3.6.1.4.1.4756.20.730.20.1.755 | Columnf2000EASSTPStatisticsPort1RxRSTPLocal | read-only | current | f2000EAS Series card STP Port Statistics: Port1 -Received RSTP |
| 1.3.6.1.4.1.4756.20.730.20.1.756 | Columnf2000EASSTPStatisticsPort1RxSTPLocal | read-only | current | f2000EAS Series card STP Port Statistics: Port1 -Received RSTP |
| 1.3.6.1.4.1.4756.20.730.20.1.757 | Columnf2000EASSTPStatisticsPort1RxTCNLocal | read-only | current | f2000EAS Series card STP Port Statistics: Port1 -Received RSTP |
| 1.3.6.1.4.1.4756.20.730.20.1.758 | Columnf2000EASSTPStatisticsPort1DiscardUnknowLocal | read-only | current | f2000EAS Series card STP Port Statistics: Port1 -Discarded Unknown |
| 1.3.6.1.4.1.4756.20.730.20.1.759 | Columnf2000EASSTPStatisticsPort1DiscardIllegalLocal | read-only | current | f2000EAS Series card STP Port Statistics: Port1 -Discarded Illegal |
| 1.3.6.1.4.1.4756.20.730.20.1.760 | Columnf2000EASSTPStatisticsPort2TxMSTPLocal | read-only | current | f2000EAS Series card STP Port Statistics: Port2 -Transmitted MSTP |
| 1.3.6.1.4.1.4756.20.730.20.1.761 | Columnf2000EASSTPStatisticsPort2TxRSTPLocal | read-only | current | f2000EAS Series card STP Port Statistics: Port2 -Transmitted RSTP |
| 1.3.6.1.4.1.4756.20.730.20.1.762 | Columnf2000EASSTPStatisticsPort2TxSTPLocal | read-only | current | f2000EAS Series card STP Port Statistics: Port2 -Transmitted RSTP |
| 1.3.6.1.4.1.4756.20.730.20.1.763 | Columnf2000EASSTPStatisticsPort2TxTCNLocal | read-only | current | f2000EAS Series card STP Port Statistics: Port2 -Transmitted RSTP |
| 1.3.6.1.4.1.4756.20.730.20.1.764 | Columnf2000EASSTPStatisticsPort2RxMSTPLocal | read-only | current | f2000EAS Series card STP Port Statistics: Port2 -Received MSTP |
| 1.3.6.1.4.1.4756.20.730.20.1.765 | Columnf2000EASSTPStatisticsPort2RxRSTPLocal | read-only | current | f2000EAS Series card STP Port Statistics: Port1 -Received RSTP |
| 1.3.6.1.4.1.4756.20.730.20.1.766 | Columnf2000EASSTPStatisticsPort2RxSTPLocal | read-only | current | f2000EAS Series card STP Port Statistics: Port2 -Received RSTP |
| 1.3.6.1.4.1.4756.20.730.20.1.767 | Columnf2000EASSTPStatisticsPort2RxTCNLocal | read-only | current | f2000EAS Series card STP Port Statistics: Port2 -Received RSTP |
| 1.3.6.1.4.1.4756.20.730.20.1.768 | Columnf2000EASSTPStatisticsPort2DiscardUnknowLocal | read-only | current | f2000EAS Series card STP Port Statistics: Port2 -Discarded Unknown |
| 1.3.6.1.4.1.4756.20.730.20.1.769 | Columnf2000EASSTPStatisticsPort2DiscardIllegalLocal | read-only | current | f2000EAS Series card STP Port Statistics: Port2 -Discarded Illegal |
| 1.3.6.1.4.1.4756.20.730.20.1.770 | Columnf2000EASSTPStatisticsPort3TxMSTPLocal | read-only | current | f2000EAS Series card STP Port Statistics: Port3 -Transmitted MSTP |
| 1.3.6.1.4.1.4756.20.730.20.1.771 | Columnf2000EASSTPStatisticsPort3TxRSTPLocal | read-only | current | f2000EAS Series card STP Port Statistics: Port3 -Transmitted RSTP |
| 1.3.6.1.4.1.4756.20.730.20.1.772 | Columnf2000EASSTPStatisticsPort3TxSTPLocal | read-only | current | f2000EAS Series card STP Port Statistics: Port3 -Transmitted RSTP |
| 1.3.6.1.4.1.4756.20.730.20.1.773 | Columnf2000EASSTPStatisticsPort3TxTCNLocal | read-only | current | f2000EAS Series card STP Port Statistics: Port3 -Transmitted RSTP |
| 1.3.6.1.4.1.4756.20.730.20.1.774 | Columnf2000EASSTPStatisticsPort3RxMSTPLocal | read-only | current | f2000EAS Series card STP Port Statistics: Port3 -Received MSTP |
| 1.3.6.1.4.1.4756.20.730.20.1.775 | Columnf2000EASSTPStatisticsPort3RxRSTPLocal | read-only | current | f2000EAS Series card STP Port Statistics: Port3 -Received RSTP |
| 1.3.6.1.4.1.4756.20.730.20.1.776 | Columnf2000EASSTPStatisticsPort3RxSTPLocal | read-only | current | f2000EAS Series card STP Port Statistics: Port3 -Received RSTP |
| 1.3.6.1.4.1.4756.20.730.20.1.777 | Columnf2000EASSTPStatisticsPort3RxTCNLocal | read-only | current | f2000EAS Series card STP Port Statistics: Port3 -Received RSTP |
| 1.3.6.1.4.1.4756.20.730.20.1.778 | Columnf2000EASSTPStatisticsPort3DiscardUnknowLocal | read-only | current | f2000EAS Series card STP Port Statistics: Port3 -Discarded Unknown |
| 1.3.6.1.4.1.4756.20.730.20.1.779 | Columnf2000EASSTPStatisticsPort3DiscardIllegalLocal | read-only | current | f2000EAS Series card STP Port Statistics: Port3 -Discarded Illegal |
| 1.3.6.1.4.1.4756.20.730.20.1.780 | Columnf2000EASSTPStatisticsPort4TxMSTPLocal | read-only | current | f2000EAS Series card STP Port Statistics: Port4 -Transmitted MSTP |
| 1.3.6.1.4.1.4756.20.730.20.1.781 | Columnf2000EASSTPStatisticsPort4TxRSTPLocal | read-only | current | f2000EAS Series card STP Port Statistics: Port4 -Transmitted RSTP |
| 1.3.6.1.4.1.4756.20.730.20.1.782 | Columnf2000EASSTPStatisticsPort4TxSTPLocal | read-only | current | f2000EAS Series card STP Port Statistics: Port4 -Transmitted RSTP |
| 1.3.6.1.4.1.4756.20.730.20.1.783 | Columnf2000EASSTPStatisticsPort4TxTCNLocal | read-only | current | f2000EAS Series card STP Port Statistics: Port4 -Transmitted RSTP |
| 1.3.6.1.4.1.4756.20.730.20.1.784 | Columnf2000EASSTPStatisticsPort4RxMSTPLocal | read-only | current | f2000EAS Series card STP Port Statistics: Port4 -Received MSTP |
| 1.3.6.1.4.1.4756.20.730.20.1.785 | Columnf2000EASSTPStatisticsPort4RxRSTPLocal | read-only | current | f2000EAS Series card STP Port Statistics: Port4 -Received RSTP |
| 1.3.6.1.4.1.4756.20.730.20.1.786 | Columnf2000EASSTPStatisticsPort4RxSTPLocal | read-only | current | f2000EAS Series card STP Port Statistics: Port4 -Received RSTP |
| 1.3.6.1.4.1.4756.20.730.20.1.787 | Columnf2000EASSTPStatisticsPort4RxTCNLocal | read-only | current | f2000EAS Series card STP Port Statistics: Port4 -Received RSTP |
| 1.3.6.1.4.1.4756.20.730.20.1.788 | Columnf2000EASSTPStatisticsPort4DiscardUnknowLocal | read-only | current | f2000EAS Series card STP Port Statistics: Port4 -Discarded Unknown |
| 1.3.6.1.4.1.4756.20.730.20.1.789 | Columnf2000EASSTPStatisticsPort4DiscardIllegalLocal | read-only | current | f2000EAS Series card STP Port Statistics: Port4 -Discarded Illegal |
| 1.3.6.1.4.1.4756.20.730.20.1.790 | Columnf2000EASSTPStatisticsPortClearCounterLocal | read-write | current | f2000EAS Series card STP Port Statistics: Clear Counters 0: OFff 1: Action |
| 1.3.6.1.4.1.4756.20.730.20.1.791 | Columnf2000EASAllowedAccessVLANsLocal | read-write | current | f2000EAS Series card Global VLAN Configuration: Allowed Access VLANs By default, only VLAN 1 is enabled. More VLANs may be created by using a list syntax where… |
| 1.3.6.1.4.1.4756.20.730.20.1.792 | Columnf2000EASVlanEthertypeLocal | read-write | current | f2000EAS Series card Global VLAN Configuration: Ethertype for Custom S-ports The format of 'Ethernet Type' is restricted to 0x600-0xFFFF |
| 1.3.6.1.4.1.4756.20.730.20.1.793 | Columnf2000EASPort1VlanModeLocal | read-write | current | f2000EAS Series card Port VLAN Configuration : Port1 - Mode 0: Access 1: Trunk 2: Hybrid |
| 1.3.6.1.4.1.4756.20.730.20.1.794 | Columnf2000EASPort1VlanIDLocal | read-write | current | f2000EAS Series card Port VLAN Configuration : Port1 - VLAN ID |
| 1.3.6.1.4.1.4756.20.730.20.1.795 | Columnf2000EASPort1VlanTypeLocal | read-write | current | f2000EAS Series card Port VLAN Configuration : Port1 - VLAN Type 0: Unaware 1: C-port 2: S-port 3: S-custom-port |
| 1.3.6.1.4.1.4756.20.730.20.1.796 | Columnf2000EASPort1VlanIngressFilteringLocal | read-write | current | f2000EAS Series card Port VLAN Configuration : Port1 - Ingress Filtering 0: Off 1: On |
| 1.3.6.1.4.1.4756.20.730.20.1.797 | Columnf2000EASPort1VlanIngressAcceptanceLocal | read-write | current | f2000EAS Series card Port VLAN Configuration : Port1 - Ingress Acceptance 0: Tagged and untagged 1: Tagged only 2: Untagged only |
| 1.3.6.1.4.1.4756.20.730.20.1.798 | Columnf2000EASPort1VlanEgressTaggingLocal | read-write | current | f2000EAS Series card Port VLAN Configuration : Port1 - Egress Tagging 0: Untag port vlan 1: Tag all 2: Untag all |
| 1.3.6.1.4.1.4756.20.730.20.1.799 | Columnf2000EASPort1VlanEgressTaggedSpecificallyUntagLocal | read-write | current | Ports in Hybrid mode may specify the tagging of frames with VID on egress, which overrules the Egress Tagging setting. Frames classified to these VLANs are tra… |
| 1.3.6.1.4.1.4756.20.730.20.1.800 | Columnf2000EASPort1VlanEgressTaggedSpecificallyCtagLocal | read-write | current | Ports in Hybrid mode may specify the tagging of frames with VID on egress, which overrules the Egress Tagging setting. Frames classified to these VLANs are tra… |
| 1.3.6.1.4.1.4756.20.730.20.1.801 | Columnf2000EASPort1VlanEgressTaggedSpecificallyStagLocal | read-write | current | Ports in Hybrid mode may specify the tagging of frames with VID on egress, which overrules the Egress Tagging setting. Frames classified to these VLANs are tra… |
| 1.3.6.1.4.1.4756.20.730.20.1.802 | Columnf2000EASPort1VlanEgressTaggedSpecificallySCtagLocal | read-write | current | Ports in Hybrid mode may specify the tagging of frames with VID on egress, which overrules the Egress Tagging setting. Frames classified to these VLANs are tra… |
| 1.3.6.1.4.1.4756.20.730.20.1.803 | Columnf2000EASPort1AllowedVLANSLocal | read-write | current | f2000EAS Series card Global VLAN Configuration: Port1 - Allowed VLANs By default, only VLAN 1 is enabled. More VLANs may be created by using a list syntax wher… |
| 1.3.6.1.4.1.4756.20.730.20.1.804 | Columnf2000EASPort2VlanModeLocal | read-write | current | f2000EAS Series card Port VLAN Configuration : Port2 - Mode 0: Access 1: Trunk 2: Hybrid |
| 1.3.6.1.4.1.4756.20.730.20.1.805 | Columnf2000EASPort2VlanIDLocal | read-write | current | f2000EAS Series card Port VLAN Configuration : Port2 - VLAN ID |
| 1.3.6.1.4.1.4756.20.730.20.1.806 | Columnf2000EASPort2VlanTypeLocal | read-write | current | f2000EAS Series card Port VLAN Configuration : Port2 - VLAN Type 0: Unaware 1: C-port 2: S-port 3: S-custom-port |
| 1.3.6.1.4.1.4756.20.730.20.1.807 | Columnf2000EASPort2VlanIngressFilteringLocal | read-write | current | f2000EAS Series card Port VLAN Configuration : Port2 - Ingress Filtering 0: Off 1: On |
| 1.3.6.1.4.1.4756.20.730.20.1.808 | Columnf2000EASPort2VlanIngressAcceptanceLocal | read-write | current | f2000EAS Series card Port VLAN Configuration : Por2 - Ingress Acceptance 0: Tagged and untagged 1: Tagged only 2: Untagged only |
| 1.3.6.1.4.1.4756.20.730.20.1.809 | Columnf2000EASPort2VlanEgressTaggingLocal | read-write | current | f2000EAS Series card Port VLAN Configuration : Port2 - Egress Tagging 0: Untag port vlan 1: Tag all 2: Untag all |
| 1.3.6.1.4.1.4756.20.730.20.1.810 | Columnf2000EASPort2VlanEgressTaggedSpecificallyUntagLocal | read-write | current | Ports in Hybrid mode may specify the tagging of frames with VID on egress, which overrules the Egress Tagging setting. Frames classified to these VLANs are tra… |
| 1.3.6.1.4.1.4756.20.730.20.1.811 | Columnf2000EASPort2VlanEgressTaggedSpecificallyCtagLocal | read-write | current | Ports in Hybrid mode may specify the tagging of frames with VID on egress, which overrules the Egress Tagging setting. Frames classified to these VLANs are tra… |
| 1.3.6.1.4.1.4756.20.730.20.1.812 | Columnf2000EASPort2VlanEgressTaggedSpecificallyStagLocal | read-write | current | Ports in Hybrid mode may specify the tagging of frames with VID on egress, which overrules the Egress Tagging setting. Frames classified to these VLANs are tra… |
| 1.3.6.1.4.1.4756.20.730.20.1.813 | Columnf2000EASPort2VlanEgressTaggedSpecificallySCtagLocal | read-write | current | Ports in Hybrid mode may specify the tagging of frames with VID on egress, which overrules the Egress Tagging setting. Frames classified to these VLANs are tra… |
| 1.3.6.1.4.1.4756.20.730.20.1.814 | Columnf2000EASPort2AllowedVLANSLocal | read-write | current | f2000EAS Series card Global VLAN Configuration: Port2 - Allowed VLANs By default, only VLAN 1 is enabled. More VLANs may be created by using a list syntax wher… |
| 1.3.6.1.4.1.4756.20.730.20.1.815 | Columnf2000EASPort3VlanModeLocal | read-write | current | f2000EAS Series card Port VLAN Configuration : Port3 - Mode 0: Access 1: Trunk 2: Hybrid |
| 1.3.6.1.4.1.4756.20.730.20.1.816 | Columnf2000EASPort3VlanIDLocal | read-write | current | f2000EAS Series card Port VLAN Configuration : Port3 - VLAN ID |
| 1.3.6.1.4.1.4756.20.730.20.1.817 | Columnf2000EASPort3VlanTypeLocal | read-write | current | f2000EAS Series card Port VLAN Configuration : Port3 - VLAN Type 0: Unaware 1: C-port 2: S-port 3: S-custom-port |
| 1.3.6.1.4.1.4756.20.730.20.1.818 | Columnf2000EASPort3VlanIngressFilteringLocal | read-write | current | f2000EAS Series card Port VLAN Configuration : Port3 - Ingress Filtering 0: Off 1: On |
| 1.3.6.1.4.1.4756.20.730.20.1.819 | Columnf2000EASPort3VlanIngressAcceptanceLocal | read-write | current | f2000EAS Series card Port VLAN Configuration : Port3 - Ingress Acceptance 0: Tagged and untagged 1: Tagged only 2: Untagged only |
| 1.3.6.1.4.1.4756.20.730.20.1.820 | Columnf2000EASPort3VlanEgressTaggingLocal | read-write | current | f2000EAS Series card Port VLAN Configuration : Port3 - Egress Tagging 0: Untag port vlan 1: Tag all 2: Untag all |
| 1.3.6.1.4.1.4756.20.730.20.1.821 | Columnf2000EASPort3VlanEgressTaggedSpecificallyUntagLocal | read-write | current | Ports in Hybrid mode may specify the tagging of frames with VID on egress, which overrules the Egress Tagging setting. Frames classified to these VLANs are tra… |
| 1.3.6.1.4.1.4756.20.730.20.1.822 | Columnf2000EASPort3VlanEgressTaggedSpecificallyCtagLocal | read-write | current | Ports in Hybrid mode may specify the tagging of frames with VID on egress, which overrules the Egress Tagging setting. Frames classified to these VLANs are tra… |
| 1.3.6.1.4.1.4756.20.730.20.1.823 | Columnf2000EASPort3VlanEgressTaggedSpecificallyStagLocal | read-write | current | Ports in Hybrid mode may specify the tagging of frames with VID on egress, which overrules the Egress Tagging setting. Frames classified to these VLANs are tra… |
| 1.3.6.1.4.1.4756.20.730.20.1.824 | Columnf2000EASPort3VlanEgressTaggedSpecificallySCtagLocal | read-write | current | Ports in Hybrid mode may specify the tagging of frames with VID on egress, which overrules the Egress Tagging setting. Frames classified to these VLANs are tra… |
| 1.3.6.1.4.1.4756.20.730.20.1.825 | Columnf2000EASPort3AllowedVLANSLocal | read-write | current | f2000EAS Series card Global VLAN Configuration: Port3 - Allowed VLANs By default, only VLAN 1 is enabled. More VLANs may be created by using a list syntax wher… |
| 1.3.6.1.4.1.4756.20.730.20.1.826 | Columnf2000EASPort4VlanModeLocal | read-write | current | f2000EAS Series card Port VLAN Configuration : Port4 - Mode 0: Access 1: Trunk 2: Hybrid |
| 1.3.6.1.4.1.4756.20.730.20.1.827 | Columnf2000EASPort4VlanIDLocal | read-write | current | f2000EAS Series card Port VLAN Configuration : Port4 - VLAN ID |
| 1.3.6.1.4.1.4756.20.730.20.1.828 | Columnf2000EASPort4VlanTypeLocal | read-write | current | f2000EAS Series card Port VLAN Configuration : Port4 - VLAN Type 0: Unaware 1: C-port 2: S-port 3: S-custom-port |
| 1.3.6.1.4.1.4756.20.730.20.1.829 | Columnf2000EASPort4VlanIngressFilteringLocal | read-write | current | f2000EAS Series card Port VLAN Configuration : Port4 - Ingress Filtering 0: Off 1: On |
| 1.3.6.1.4.1.4756.20.730.20.1.830 | Columnf2000EASPort4VlanIngressAcceptanceLocal | read-write | current | f2000EAS Series card Port VLAN Configuration : Port4 - Ingress Acceptance 0: Tagged and untagged 1: Tagged only 2: Untagged only |
| 1.3.6.1.4.1.4756.20.730.20.1.831 | Columnf2000EASPort4VlanEgressTaggingLocal | read-write | current | f2000EAS Series card Port VLAN Configuration : Port4 - Egress Tagging 0: Untag port vlan 1: Tag all 2: Untag all |
| 1.3.6.1.4.1.4756.20.730.20.1.832 | Columnf2000EASPort4VlanEgressTaggedSpecificallyUntagLocal | read-write | current | Ports in Hybrid mode may specify the tagging of frames with VID on egress, which overrules the Egress Tagging setting. Frames classified to these VLANs are tra… |
| 1.3.6.1.4.1.4756.20.730.20.1.833 | Columnf2000EASPort4VlanEgressTaggedSpecificallyCtagLocal | read-write | current | Ports in Hybrid mode may specify the tagging of frames with VID on egress, which overrules the Egress Tagging setting. Frames classified to these VLANs are tra… |
| 1.3.6.1.4.1.4756.20.730.20.1.834 | Columnf2000EASPort4VlanEgressTaggedSpecificallyStagLocal | read-write | current | Ports in Hybrid mode may specify the tagging of frames with VID on egress, which overrules the Egress Tagging setting. Frames classified to these VLANs are tra… |
| 1.3.6.1.4.1.4756.20.730.20.1.835 | Columnf2000EASPort4VlanEgressTaggedSpecificallySCtagLocal | read-write | current | Ports in Hybrid mode may specify the tagging of frames with VID on egress, which overrules the Egress Tagging setting. Frames classified to these VLANs are tra… |
| 1.3.6.1.4.1.4756.20.730.20.1.836 | Columnf2000EASPort4AllowedVLANSLocal | read-write | current | f2000EAS Series card Global VLAN Configuration: Port4 - Allowed VLANs By default, only VLAN 1 is enabled. More VLANs may be created by using a list syntax wher… |
| 1.3.6.1.4.1.4756.20.730.20.1.837 | Columnf2000EASQOSPort1IngressLocal | read-write | current | f2000EAS Series card QOS Port1 Ingress Enabled 0: NO 1: YES |
| 1.3.6.1.4.1.4756.20.730.20.1.838 | Columnf2000EASQOSPort1IngressRateLocal | read-write | current | f2000EAS Series card QOS Port1 Ingress Rate |
| 1.3.6.1.4.1.4756.20.730.20.1.839 | Columnf2000EASQOSPort1IngressRateUnitLocal | read-write | current | f2000EAS Series card QOS Port1 Ingress Rate Unit 0: Kbps 1: Mbps 2: fps 3: kfps |
| 1.3.6.1.4.1.4756.20.730.20.1.840 | Columnf2000EASQOSPort1IngressBurstSizeLocal | read-write | current | f2000EAS Series card QOS Port1 Ingress Burst Size |
| 1.3.6.1.4.1.4756.20.730.20.1.841 | Columnf2000EASQOSPort2IngressLocal | read-write | current | f2000EAS Series card QOS Port2 Ingress Enabled 0: NO 1: YES |
| 1.3.6.1.4.1.4756.20.730.20.1.842 | Columnf2000EASQOSPort2IngressRateLocal | read-write | current | f2000EAS Series card QOS Port2 Ingress Rate |
| 1.3.6.1.4.1.4756.20.730.20.1.843 | Columnf2000EASQOSPort2IngressRateUnitLocal | read-write | current | f2000EAS Series card QOS Port2 Ingress Rate Unit 0: Kbps 1: Mbps 2: fps 3: kfps |
| 1.3.6.1.4.1.4756.20.730.20.1.844 | Columnf2000EASQOSPort2IngressBurstSizeLocal | read-write | current | f2000EAS Series card QOS Port2 Ingress Burst Size |
| 1.3.6.1.4.1.4756.20.730.20.1.845 | Columnf2000EASQOSPort3IngressLocal | read-write | current | f2000EAS Series card QOS Port3 Ingress Enabled 0: NO 1: YES |
| 1.3.6.1.4.1.4756.20.730.20.1.846 | Columnf2000EASQOSPort3IngressRateLocal | read-write | current | f2000EAS Series card QOS Port3 Ingress Rate |
| 1.3.6.1.4.1.4756.20.730.20.1.847 | Columnf2000EASQOSPort3IngressRateUnitLocal | read-write | current | f2000EAS Series card QOS Port3 Ingress Rate Unit 0: Kbps 1: Mbps 2: fps 3: kfps |
| 1.3.6.1.4.1.4756.20.730.20.1.848 | Columnf2000EASQOSPort3IngressBurstSizeLocal | read-write | current | f2000EAS Series card QOS Port3 Ingress Burst Size |
| 1.3.6.1.4.1.4756.20.730.20.1.849 | Columnf2000EASQOSPort4IngressLocal | read-write | current | f2000EAS Series card QOS Port4 Ingress Enabled 0: NO 1: YES |
| 1.3.6.1.4.1.4756.20.730.20.1.850 | Columnf2000EASQOSPort4IngressRateLocal | read-write | current | f2000EAS Series card QOS Port4 Ingress Rate |
| 1.3.6.1.4.1.4756.20.730.20.1.851 | Columnf2000EASQOSPort4IngressRateUnitLocal | read-write | current | f2000EAS Series card QOS Port4 Ingress Rate Unit 0: Kbps 1: Mbps 2: fps 3: kfps |
| 1.3.6.1.4.1.4756.20.730.20.1.852 | Columnf2000EASQOSPort4IngressBurstSizeLocal | read-write | current | f2000EAS Series card QOS Port4 Ingress Burst Size |
| 1.3.6.1.4.1.4756.20.730.20.1.853 | Columnf2000EASQOSPort1EgressLocal | read-write | current | f2000EAS Series card QOS Port1 Egress Enabled 0: NO 1: YES |
| 1.3.6.1.4.1.4756.20.730.20.1.854 | Columnf2000EASQOSPort1EgressRateLocal | read-write | current | f2000EAS Series card QOS Port1 Egress Rate |
| 1.3.6.1.4.1.4756.20.730.20.1.855 | Columnf2000EASQOSPort1EgressRateUnitLocal | read-write | current | f2000EAS Series card QOS Port1 Egress Rate Unit 0: Kbps 1: Mbps |
| 1.3.6.1.4.1.4756.20.730.20.1.856 | Columnf2000EASQOSPort2EgressLocal | read-write | current | f2000EAS Series card QOS Port2 Egress Enabled 0: NO 1: YES |
| 1.3.6.1.4.1.4756.20.730.20.1.857 | Columnf2000EASQOSPort2EgressRateLocal | read-write | current | f2000EAS Series card QOS Port2 Egress Rate |
| 1.3.6.1.4.1.4756.20.730.20.1.858 | Columnf2000EASQOSPort2EgressRateUnitLocal | read-write | current | f2000EAS Series card QOS Port2 Egress Rate Unit 0: Kbps 1: Mbps |
| 1.3.6.1.4.1.4756.20.730.20.1.859 | Columnf2000EASQOSPort3EgressLocal | read-write | current | f2000EAS Series card QOS Port3 Egress Enabled 0: NO 1: YES |
| 1.3.6.1.4.1.4756.20.730.20.1.860 | Columnf2000EASQOSPort3EgressRateLocal | read-write | current | f2000EAS Series card QOS Port3 Egress Rate |
| 1.3.6.1.4.1.4756.20.730.20.1.861 | Columnf2000EASQOSPort3EgressRateUnitLocal | read-write | current | f2000EAS Series card QOS Port3 Egress Rate Unit 0: Kbps 1: Mbps |
| 1.3.6.1.4.1.4756.20.730.20.1.862 | Columnf2000EASQOSPort4EgressLocal | read-write | current | f2000EAS Series card QOS Port4 Egress Enabled 0: NO 1: YES |
| 1.3.6.1.4.1.4756.20.730.20.1.863 | Columnf2000EASQOSPort4EgressRateLocal | read-write | current | f2000EAS Series card QOS Port4 Egress Rate |
| 1.3.6.1.4.1.4756.20.730.20.1.864 | Columnf2000EASQOSPort4EgressRateUnitLocal | read-write | current | f2000EAS Series card QOS Port4 Egress Rate Unit 0: Kbps 1: Mbps |
| 1.3.6.1.4.1.4756.20.730.20.1.865 | Columnf2000EASQOSUnicastLocal | read-write | current | f2000EAS Series card QOS Storm Control Configuration- Unicast 0: NO 1: YES |
| 1.3.6.1.4.1.4756.20.730.20.1.866 | Columnf2000EASQOSUnicastRateLocal | read-write | current | f2000EAS Series card QOS Storm Control Configuration- Unicast Rate |
| 1.3.6.1.4.1.4756.20.730.20.1.867 | Columnf2000EASQOSUnicastRateUnitLocal | read-only | current | f2000EAS Series card QOS Unicast Rate Unit 2: Fps 3: Kfps |
| 1.3.6.1.4.1.4756.20.730.20.1.868 | Columnf2000EASQOSMulticastLocal | read-write | current | f2000EAS Series card QOS Storm Control Configuration- Multicast 0: NO 1: YES |
| 1.3.6.1.4.1.4756.20.730.20.1.869 | Columnf2000EASQOSMulticastRateLocal | read-write | current | f2000EAS Series card QOS Storm Control Configuration- Multicast Rate |
| 1.3.6.1.4.1.4756.20.730.20.1.870 | Columnf2000EASQOSMulticastRateUnitLocal | read-only | current | f2000EAS Series card QOS Multicast Rate Unit 2: Fps 3: Kfps |
| 1.3.6.1.4.1.4756.20.730.20.1.871 | Columnf2000EASQOSBroadcastLocal | read-write | current | f2000EAS Series card QOS Storm Control Configuration- Broadcast 0: NO 1: YES |
| 1.3.6.1.4.1.4756.20.730.20.1.872 | Columnf2000EASQOSBroadcastRateLocal | read-write | current | f2000EAS Series card QOS Storm Control Configuration- Broadcast Rate |
| 1.3.6.1.4.1.4756.20.730.20.1.873 | Columnf2000EASQOSBroadcastRateUnitLocal | read-only | current | f2000EAS Series card QOS Broadcast Rate Unit 2: Fps 3: Kfps |
| 1.3.6.1.4.1.4756.20.730.20.1.874 | Columnf2000EASPort1LLFLogicLocal | read-write | current | f2000EAS Series card Port1 link loss forwarding - Logic 0: AND 1: OR |
| 1.3.6.1.4.1.4756.20.730.20.1.875 | Columnf2000EASPort1LLFLogicPort2Local | read-write | current | f2000EAS Series card Port1 link loss forwarding - Link/Rx Loss Port2 0: NO 1: YES |
| 1.3.6.1.4.1.4756.20.730.20.1.876 | Columnf2000EASPort1LLFLogicPort3Local | read-write | current | f2000EAS Series card Port1 link loss forwarding - Link/Rx Loss Port3 0: NO 1: YES |
| 1.3.6.1.4.1.4756.20.730.20.1.877 | Columnf2000EASPort1LLFLogicPort4Local | read-write | current | f2000EAS Series card Port1 link loss forwarding - Link/Rx Loss Port4 0: NO 1: YES |
| 1.3.6.1.4.1.4756.20.730.20.1.878 | Columnf2000EASPort2LLFLogicLocal | read-write | current | f2000EAS Series card Port2 link loss forwarding - Logic 0: AND 1: OR |
| 1.3.6.1.4.1.4756.20.730.20.1.879 | Columnf2000EASPort2LLFLogicPort1Local | read-write | current | f2000EAS Series card Port2 link loss forwarding - Link/Rx Loss Port1 0: NO 1: YES |
| 1.3.6.1.4.1.4756.20.730.20.1.880 | Columnf2000EASPort2LLFLogicPort3Local | read-write | current | f2000EAS Series card Port2 link loss forwarding - Link/Rx Loss Port3 0: NO 1: YES |
| 1.3.6.1.4.1.4756.20.730.20.1.881 | Columnf2000EASPort2LLFLogicPort4Local | read-write | current | f2000EAS Series card Port2 link loss forwarding - Link/Rx Loss Port4 0: NO 1: YES |
| 1.3.6.1.4.1.4756.20.730.20.1.882 | Columnf2000EASPort3LLFLogicLocal | read-write | current | f2000EAS Series card Port3 link loss forwarding - Logic 0: AND 1: OR |
| 1.3.6.1.4.1.4756.20.730.20.1.883 | Columnf2000EASPort3LLFLogicPort1Local | read-write | current | f2000EAS Series card Port3 link loss forwarding - Link/Rx Loss Port1 0: NO 1: YES |
| 1.3.6.1.4.1.4756.20.730.20.1.884 | Columnf2000EASPort3LLFLogicPort2Local | read-write | current | f2000EAS Series card Port3 link loss forwarding - Link/Rx Loss Port2 0: NO 1: YES |
| 1.3.6.1.4.1.4756.20.730.20.1.885 | Columnf2000EASPort3LLFLogicPort4Local | read-write | current | f2000EAS Series card Port3 link loss forwarding - Link/Rx Loss Port4 0: NO 1: YES |
| 1.3.6.1.4.1.4756.20.730.20.1.886 | Columnf2000EASPort4LLFLogicLocal | read-write | current | f2000EAS Series card Port4 link loss forwarding - Logic 0: AND 1: OR |
| 1.3.6.1.4.1.4756.20.730.20.1.887 | Columnf2000EASPort4LLFLogicPort1Local | read-write | current | f2000EAS Series card Port4 link loss forwarding - Link/Rx Loss Port1 0: NO 1: YES |
| 1.3.6.1.4.1.4756.20.730.20.1.888 | Columnf2000EASPort4LLFLogicPort2Local | read-write | current | f2000EAS Series card Port4 link loss forwarding - Link/Rx Loss Port2 0: NO 1: YES |
| 1.3.6.1.4.1.4756.20.730.20.1.889 | Columnf2000EASPort4LLFLogicPort3Local | read-write | current | f2000EAS Series card Port4 link loss forwarding - Link/Rx Loss Port3 0: NO 1: YES |
| 1.3.6.1.4.1.4756.20.730.20.1.890 | Columnf2000EASAddIPRouteLocal | read-write | current | f2000EAS Series card IP Routes: Add a new IP Routes : Syntax: [<Interface>] [<network>] [<mask_len>] [<gateway>] [<next_hop_vlan>] Interface : 1~4 |
| 1.3.6.1.4.1.4756.20.730.20.1.891 | Columnf2000EASDeleteIPRouteLocal | read-write | current | f2000EAS Series card IP Routes num: Delete a IP Routes num: Syntax: [<Interface>] Interface: 1~4 |
| 1.3.6.1.4.1.4756.20.730.20.1.892 | Columnf2000EASPort1RemotePowerStsLocal | read-only | current | f2000EAS Series card Port1 remote Power status 0: None 1: OK 2: Abnormal |
| 1.3.6.1.4.1.4756.20.730.20.1.893 | Columnf2000EASPort2RemotePowerStsLocal | read-only | current | f2000EAS Series card Port2 remote Power status 0: None 1: OK 2: Abnormal |
| 1.3.6.1.4.1.4756.20.730.20.1.894 | Columnf2000EASPort3RemotePowerStsLocal | read-only | current | f2000EAS Series card Port3 remote Power status 0: None 1: OK 2: Abnormal |
| 1.3.6.1.4.1.4756.20.730.20.1.895 | Columnf2000EASPort4RemotePowerStsLocal | read-only | current | f2000EAS Series card Port4 remote Power status 0: None 1: OK 2: Abnormal |
| 1.3.6.1.4.1.4756.20.730.20.1.896 | Columnf2000EASPort1LinkAlarmLocal | read-write | current | f2000EAS Series card Port 1 Link alarm: 0: Disable 1: Enable |
| 1.3.6.1.4.1.4756.20.730.20.1.897 | Columnf2000EASPort2LinkAlarmLocal | read-write | current | f2000EAS Series card Port 2 Link alarm: 0: Disable 1: Enable |
| 1.3.6.1.4.1.4756.20.730.20.1.898 | Columnf2000EASPort3LinkAlarmLocal | read-write | current | f2000EAS Series card Port 3 Link alarm: 0: Disable 1: Enable |
| 1.3.6.1.4.1.4756.20.730.20.1.899 | Columnf2000EASPort4LinkAlarmLocal | read-write | current | f2000EAS Series card Port 4 Link alarm: 0: Disable 1: Enable |
| 1.3.6.1.4.1.4756.20.730.20.1.900 | Columnf2000EASRemoteAHWResetLocal | read-write | current | f2000EAS Series card Remote A H/W Reset: 0: OFF 1: action |
| 1.3.6.1.4.1.4756.20.730.20.1.901 | Columnf2000EASRemoteBHWResetLocal | read-write | current | f2000EAS Series card Remote B H/W Reset: 0: OFF 1: action |
| 1.3.6.1.4.1.4756.20.730.20.1.902 | Columnf2000EASRemoteTLPTLocal | read-write | current | f2000EAS Series card Remote TLPT: 0: Disable 1: RemoteA 2: RemoteB |
| 1.3.6.1.4.1.4756.20.731 | Nodef2000EASRemoteACards | |||
| 1.3.6.1.4.1.4756.20.731.20 | Tablef2000EASRemoteATable | not-accessible | current | A list of RemoteA FRM220A-2000EAS series card entries. |
| 1.3.6.1.4.1.4756.20.731.20.1 | Rowf2000EASRemoteAEntry | not-accessible | current | An entry containing management information applicable to a particular FRM220A-2000EAS series card. |
| 1.3.6.1.4.1.4756.20.731.20.1.1 | Columnf2000EASChassisIndexRemoteA | read-only | current | A unique value for each card. It starts from 0 to 9 contiguously. |
| 1.3.6.1.4.1.4756.20.731.20.1.2 | Columnf2000EASSlotIndexRemoteA | read-only | current | A unique value for each card. It starts from 1 to 20 contiguously. |
| 1.3.6.1.4.1.4756.20.731.20.1.3 | Columnf2000EASCardHWVerRemoteA | read-only | current | f2000EAS Series card hardware version x.xxx |
| 1.3.6.1.4.1.4756.20.731.20.1.4 | Columnf2000EASCardFWVerRemoteA | read-only | current | f2000EAS Series card firmware version x.xxx |
| 1.3.6.1.4.1.4756.20.731.20.1.5 | Columnf2000EASCardCPLDVerRemoteA | read-only | current | f2000EAS Series card CPLD version x.xxx |
| 1.3.6.1.4.1.4756.20.731.20.1.6 | Columnf2000EASCardFPGAVerRemoteA | read-only | current | f2000EAS Series card FPGA version x.xxx |
| 1.3.6.1.4.1.4756.20.731.20.1.7 | Columnf2000EASModelRemoteA | read-only | current | Card Type: 0:2000EAS/4F 1:2000EAS/2F 2:2000EAS/1F |
| 1.3.6.1.4.1.4756.20.731.20.1.8 | Columnf2000EASDNSServerTypeRemoteA | read-write | current | f2000EAS Series card IP Configuration: This setting controls the DNS name resolution done by the switch. The following modes are supported: 0:No DNS server No … |
| 1.3.6.1.4.1.4756.20.731.20.1.9 | Columnf2000EASDNSServerSettingRemoteA | read-write | current | f2000EAS Series card IP Configuration: If iDNSServerType setting '3:Configured',this value must setting IP address format as below: Dotted Decimal Notation ref… |
| 1.3.6.1.4.1.4756.20.731.20.1.10 | Columnf2000EASDNSproxyRemoteA | read-write | current | f2000EAS Series card IP Configuration: When DNS proxy is enabled, system will relay DNS requests to the currently configured DNS server, and reply as a DNS res… |
| 1.3.6.1.4.1.4756.20.731.20.1.11 | Columnf2000EASAddIPV4InterfaceRemoteA | read-write | current | f2000EAS Series card IP Interfaces: Add a new IP VLAN Interface: Syntax: [<Interface>] [<vlan_list>] [<IPV4_Addr>] [<IPV4_MASK>] Interface : 1~4 |
| 1.3.6.1.4.1.4756.20.731.20.1.12 | Columnf2000EASDeleteInterfaceRemoteA | read-write | current | f2000EAS Series card IP Interfaces: Delete a IPv4/v6 VLAN Interface: Syntax: [<Interface>] Interface: 1~4 |
| 1.3.6.1.4.1.4756.20.731.20.1.13 | Columnf2000EASIPInterface1VLANRemoteA | read-only | current | f2000EAS Series card IP Interfaces: The VLAN associated with the IP interface. Only ports in this VLAN will be able to access the IP interface. This field is o… |
| 1.3.6.1.4.1.4756.20.731.20.1.14 | Columnf2000EASIPInterface1DHCPRemoteA | read-write | current | f2000EAS Series card IP Interfaces: DHCP |
| 1.3.6.1.4.1.4756.20.731.20.1.15 | Columnf2000EASIPInterface1FallbackRemoteA | read-write | current | f2000EAS Series card IP Interfaces: Fallback |
| 1.3.6.1.4.1.4756.20.731.20.1.16 | Columnf2000EASIPInterface1IPV4CurrentLeaseRemoteA | read-only | current | f2000EAS Series card IP Interfaces: IPV4 Current Lease Address |
| 1.3.6.1.4.1.4756.20.731.20.1.17 | Columnf2000EASIPInterface1IPV4AddressRemoteA | read-only | current | f2000EAS Series card IP Interfaces: IPV4 Address |
| 1.3.6.1.4.1.4756.20.731.20.1.18 | Columnf2000EASIPInterface1IPV4MASKLenRemoteA | read-only | current | f2000EAS Series card IP Interfaces: IPV4 MASK Length |
| 1.3.6.1.4.1.4756.20.731.20.1.19 | Columnf2000EASIPInterface2VLANRemoteA | read-only | current | f2000EAS Series card IP Interfaces: The VLAN associated with the IP interface. Only ports in this VLAN will be able to access the IP interface. This field is o… |
| 1.3.6.1.4.1.4756.20.731.20.1.20 | Columnf2000EASIPInterface2DHCPRemoteA | read-write | current | f2000EASEDD Series card IP Interfaces: DHCP |
| 1.3.6.1.4.1.4756.20.731.20.1.21 | Columnf2000EASIPInterface2FallbackRemoteA | read-write | current | f2000EASEDD Series card IP Interfaces: Fallback |
| 1.3.6.1.4.1.4756.20.731.20.1.22 | Columnf2000EASIPInterface2IPV4CurrentLeaseRemoteA | read-only | current | f2000EAS Series card IP Interfaces: IPV4 Current Lease Address |
| 1.3.6.1.4.1.4756.20.731.20.1.23 | Columnf2000EASIPInterface2IPV4AddressRemoteA | read-only | current | f2000EAS Series card IP Interfaces: IPV4 Address |
| 1.3.6.1.4.1.4756.20.731.20.1.24 | Columnf2000EASIPInterface2IPV4MASKLenRemoteA | read-only | current | f2000EAS Series card IP Interfaces: IPV4 MASK Length |
| 1.3.6.1.4.1.4756.20.731.20.1.25 | Columnf2000EASIPInterface3VLANRemoteA | read-only | current | f2000EAS Series card IP Interfaces: The VLAN associated with the IP interface. Only ports in this VLAN will be able to access the IP interface. This field is o… |
| 1.3.6.1.4.1.4756.20.731.20.1.26 | Columnf2000EASIPInterface3DHCPRemoteA | read-write | current | f2000EAS Series card IP Interfaces: DHCP |
| 1.3.6.1.4.1.4756.20.731.20.1.27 | Columnf2000EASIPInterface3FallbackRemoteA | read-write | current | f2000EAS Series card IP Interfaces: Fallback |
| 1.3.6.1.4.1.4756.20.731.20.1.28 | Columnf2000EASIPInterface3IPV4CurrentLeaseRemoteA | read-only | current | f2000EAS Series card IP Interfaces: IPV4 Current Lease Address |
| 1.3.6.1.4.1.4756.20.731.20.1.29 | Columnf2000EASIPInterface3IPV4AddressRemoteA | read-only | current | f2000EAS Series card IP Interfaces: IPV4 Address |
| 1.3.6.1.4.1.4756.20.731.20.1.30 | Columnf2000EASIPInterface3IPV4MASKLenRemoteA | read-only | current | f2000EAS Series card IP Interfaces: IPV4 MASK Length |
| 1.3.6.1.4.1.4756.20.731.20.1.31 | Columnf2000EASIPInterface4VLANRemoteA | read-only | current | f2000EAS Series card IP Interfaces: The VLAN associated with the IP interface. Only ports in this VLAN will be able to access the IP interface. This field is o… |
| 1.3.6.1.4.1.4756.20.731.20.1.32 | Columnf2000EASIPInterface4DHCPRemoteA | read-write | current | f2000EAS Series card IP Interfaces: DHCP |
| 1.3.6.1.4.1.4756.20.731.20.1.33 | Columnf2000EASIPInterface4FallbackRemoteA | read-write | current | f2000EAS Series card IP Interfaces: Fallback |
| 1.3.6.1.4.1.4756.20.731.20.1.34 | Columnf2000EASIPInterface4IPV4CurrentLeaseRemoteA | read-only | current | f2000EAS Series card IP Interfaces: IPV4 Current Lease Address |
| 1.3.6.1.4.1.4756.20.731.20.1.35 | Columnf2000EASIPInterface4IPV4AddressRemoteA | read-only | current | f2000EAS Series card IP Interfaces: IPV4 Address |
| 1.3.6.1.4.1.4756.20.731.20.1.36 | Columnf2000EASIPInterface4IPV4MASKLenRemoteA | read-only | current | f2000EAS Series card IP Interfaces: IPV4 MASK Length |
| 1.3.6.1.4.1.4756.20.731.20.1.37 | Columnf2000EASAddIPV6InterfaceRemoteA | read-write | current | f2000EAS Series card IP Interfaces: Add a new IPv6 VLAN Interface: Syntax: [<Interface>] [<vlan_list>] [<IPV4_Addr>] [<IPV4_MASK>] Interface : 1~4 |
| 1.3.6.1.4.1.4756.20.731.20.1.38 | Columnf2000EASIPInterface1IPV6DHCPRemoteA | read-write | current | f2000EAS Series card IP Interfaces: IPV6 DHCP |
| 1.3.6.1.4.1.4756.20.731.20.1.39 | Columnf2000EASIPInterface1IPV6RapidCommitRemoteA | read-write | current | f2000EAS Series card IP Interfaces1: IPV6 RapidCommit |
| 1.3.6.1.4.1.4756.20.731.20.1.40 | Columnf2000EASIPInterface1IPV6CurrentLeaseRemoteA | read-only | current | f2000EAS Series card IP Interfaces: IPV6 Current lease Address |
| 1.3.6.1.4.1.4756.20.731.20.1.41 | Columnf2000EASIPInterface1IPV6AddressRemoteA | read-only | current | f2000EAS Series card IP Interfaces: IPV6 Address |
| 1.3.6.1.4.1.4756.20.731.20.1.42 | Columnf2000EASIPInterface1IPV6MASKLenRemoteA | read-only | current | f2000EAS Series card IP Interfaces: IPV6 MASK Length |
| 1.3.6.1.4.1.4756.20.731.20.1.43 | Columnf2000EASIPInterface2IPV6DHCPRemoteA | read-write | current | f2000EAS Series card IP Interfaces2: IPV6 DHCP |
| 1.3.6.1.4.1.4756.20.731.20.1.44 | Columnf2000EASIPInterface2IPV6RapidCommitRemoteA | read-write | current | f2000EAS Series card IP Interfaces2: IPV6 RapidCommit |
| 1.3.6.1.4.1.4756.20.731.20.1.45 | Columnf2000EASIPInterface2IPV6CurrentLeaseRemoteA | read-only | current | f2000EAS Series card IP Interfaces: IPV6 Current lease Address |
| 1.3.6.1.4.1.4756.20.731.20.1.46 | Columnf2000EASIPInterface2IPV6AddressRemoteA | read-only | current | f2000EAS Series card IP Interfaces: IPV6 Address |
| 1.3.6.1.4.1.4756.20.731.20.1.47 | Columnf2000EASIPInterface2IPV6MASKLenRemoteA | read-only | current | f2000EAS Series card IP Interfaces: IPV6 MASK Length |
| 1.3.6.1.4.1.4756.20.731.20.1.48 | Columnf2000EASIPInterface3IPV6DHCPRemoteA | read-write | current | f2000EAS Series card IP Interfaces2: IPV6 DHCP |
| 1.3.6.1.4.1.4756.20.731.20.1.49 | Columnf2000EASIPInterface3IPV6RapidCommitRemoteA | read-write | current | f2000EAS Series card IP Interfaces3: IPV6 RapidCommit |
| 1.3.6.1.4.1.4756.20.731.20.1.50 | Columnf2000EASIPInterface3IPV6CurrentLeaseRemoteA | read-only | current | f2000EAS Series card IP Interfaces: IPV6 Current lease Address |
| 1.3.6.1.4.1.4756.20.731.20.1.51 | Columnf2000EASIPInterface3IPV6AddressRemoteA | read-only | current | f2000EAS Series card IP Interfaces3: IPV6 Address |
| 1.3.6.1.4.1.4756.20.731.20.1.52 | Columnf2000EASIPInterface3IPV6MASKLenRemoteA | read-only | current | f2000EAS Series card IP Interfaces: IPV6 MASK Length |
| 1.3.6.1.4.1.4756.20.731.20.1.53 | Columnf2000EASIPInterface4IPV6DHCPRemoteA | read-write | current | f2000EAS Series card IP Interfaces4: IPV6 DHCP |
| 1.3.6.1.4.1.4756.20.731.20.1.54 | Columnf2000EASIPInterface4IPV6RapidCommitRemoteA | read-write | current | f2000EAS Series card IP Interfaces4: IPV6 RapidCommit |
| 1.3.6.1.4.1.4756.20.731.20.1.55 | Columnf2000EASIPInterface4IPV6CurrentLeaseRemoteA | read-only | current | f2000EAS Series card IP Interfaces: IPV6 Current lease Address |
| 1.3.6.1.4.1.4756.20.731.20.1.56 | Columnf2000EASIPInterface4IPV6AddressRemoteA | read-only | current | f2000EAS Series card IP Interfaces: IPV6 Address |
| 1.3.6.1.4.1.4756.20.731.20.1.57 | Columnf2000EASIPInterface4IPV6MASKLenRemoteA | read-only | current | f2000EAS Series card IP Interfaces: IPV6 MASK Length |
| 1.3.6.1.4.1.4756.20.731.20.1.58 | Columnf2000EASIPRoutes1NetworkRemoteA | read-only | current | f2000EAS Series card IP Routes: NetWork |
| 1.3.6.1.4.1.4756.20.731.20.1.59 | Columnf2000EASIPRoutes1MASKLenRemoteA | read-only | current | f2000EAS Series card IP Routes: MASK Length |
| 1.3.6.1.4.1.4756.20.731.20.1.60 | Columnf2000EASIPRoutes1GetwayRemoteA | read-only | current | f2000EAS Series card IP Routes: Getway |
| 1.3.6.1.4.1.4756.20.731.20.1.61 | Columnf2000EASIPRoutes1HopVLANRemoteA | read-only | current | f2000EAS Series card IP Routes: The VLAN associated with the IP Routes. Only ports in this VLAN will be able to access the IP Routes. |
| 1.3.6.1.4.1.4756.20.731.20.1.62 | Columnf2000EASIPRoutes2NetworkRemoteA | read-only | current | f2000EAS Series card IP Routes: NetWork |
| 1.3.6.1.4.1.4756.20.731.20.1.63 | Columnf2000EASIPRoutes2MASKLenRemoteA | read-only | current | f2000EAS Series card IP Routes: MASK Length |
| 1.3.6.1.4.1.4756.20.731.20.1.64 | Columnf2000EASIPRoutes2GetwayRemoteA | read-only | current | f2000EAS Series card IP Routes: Getway |
| 1.3.6.1.4.1.4756.20.731.20.1.65 | Columnf2000EASIPRoutes2HopVLANRemoteA | read-only | current | f2000EAS Series card IP Routes: The VLAN associated with the IP Routes. Only ports in this VLAN will be able to access the IP Routes. |
| 1.3.6.1.4.1.4756.20.731.20.1.66 | Columnf2000EASIPRoutes3NetworkRemoteA | read-only | current | f2000EAS Series card IP Routes: NetWork |
| 1.3.6.1.4.1.4756.20.731.20.1.67 | Columnf2000EASIPRoutes3MASKLenRemoteA | read-only | current | f2000EAS Series card IP Routes: MASK Length |
| 1.3.6.1.4.1.4756.20.731.20.1.68 | Columnf2000EASIPRoutes3GetwayRemoteA | read-only | current | f2000EAS Series card IP Routes: Getway |
| 1.3.6.1.4.1.4756.20.731.20.1.69 | Columnf2000EASIPRoutes3HopVLANRemoteA | read-only | current | f2000EAS Series card IP Routes: The VLAN associated with the IP Routes. Only ports in this VLAN will be able to access the IP Routes. |
| 1.3.6.1.4.1.4756.20.731.20.1.70 | Columnf2000EASIPRoutes4NetworkRemoteA | read-only | current | f2000EAS Series card IP Routes: NetWork |
| 1.3.6.1.4.1.4756.20.731.20.1.71 | Columnf2000EASIPRoutes4MASKLenRemoteA | read-only | current | f2000EAS Series card IP Routes: MASK Length |
| 1.3.6.1.4.1.4756.20.731.20.1.72 | Columnf2000EASIPRoutes4GetwayRemoteA | read-only | current | f2000EAS Series card IP Routes: Getway |
| 1.3.6.1.4.1.4756.20.731.20.1.73 | Columnf2000EASIPRoutes4HopVLANRemoteA | read-only | current | f2000EAS Series card IP Routes: The VLAN associated with the IP Routes. Only ports in this VLAN will be able to access the IP Routes. |
| 1.3.6.1.4.1.4756.20.731.20.1.74 | Columnf2000EASPort1LinkstsRemoteA | read-only | current | f2000EAS Series card Port1 link status: 0:Link down 1:Link up |
| 1.3.6.1.4.1.4756.20.731.20.1.75 | Columnf2000EASPort1SpeedstsRemoteA | read-only | current | f2000EAS Series card Port1 speed status |
| 1.3.6.1.4.1.4756.20.731.20.1.76 | Columnf2000EASPort1DuplexstsRemoteA | read-only | current | f2000EAS Series card Port1 duplex status 0: Half 1: Full |
| 1.3.6.1.4.1.4756.20.731.20.1.77 | Columnf2000EASPort1RxPausestsRemoteA | read-only | current | f2000EAS Series card Port1 rx pause status 0: No 1: Yes |
| 1.3.6.1.4.1.4756.20.731.20.1.78 | Columnf2000EASPort1TxPausestsRemoteA | read-only | current | f2000EAS Series card Port1 tx pause status 0: No 1: Yes |
| 1.3.6.1.4.1.4756.20.731.20.1.79 | Columnf2000EASPort2LinkstsRemoteA | read-only | current | f2000EAS Series card Port2 link status: 0:Link down 1:Link up |
| 1.3.6.1.4.1.4756.20.731.20.1.80 | Columnf2000EASPort2SpeedstsRemoteA | read-only | current | f2000EAS Series card Port2 speed status |
| 1.3.6.1.4.1.4756.20.731.20.1.81 | Columnf2000EASPort2DuplexstsRemoteA | read-only | current | f2000EAS Series card Port2 duplex status 0: Half 1: Full |
| 1.3.6.1.4.1.4756.20.731.20.1.82 | Columnf2000EASPort2RxPausestsRemoteA | read-only | current | f2000EAS Series card Port2 rx pause status 0: No 1: Yes |
| 1.3.6.1.4.1.4756.20.731.20.1.83 | Columnf2000EASPort2TxPausestsRemoteA | read-only | current | f2000EAS Series card Port2 tx pause status 0: No 1: Yes |
| 1.3.6.1.4.1.4756.20.731.20.1.84 | Columnf2000EASPort3LinkstsRemoteA | read-only | current | f2000EAS Series card Port3 link status: 0:Link down 1:Link up |
| 1.3.6.1.4.1.4756.20.731.20.1.85 | Columnf2000EASPort3SpeedstsRemoteA | read-only | current | f2000EAS Series card Port3 speed status |
| 1.3.6.1.4.1.4756.20.731.20.1.86 | Columnf2000EASPort3DuplexstsRemoteA | read-only | current | f2000EAS Series card Port3 duplex status 0: Half 1: Full |
| 1.3.6.1.4.1.4756.20.731.20.1.87 | Columnf2000EASPort3RxPausestsRemoteA | read-only | current | f2000EAS Series card Port3 rx pause status 0: No 1: Yes |
| 1.3.6.1.4.1.4756.20.731.20.1.88 | Columnf2000EASPort3TxPausestsRemoteA | read-only | current | f2000EAS Series card Port3 tx pause status 0: No 1: Yes |
| 1.3.6.1.4.1.4756.20.731.20.1.89 | Columnf2000EASPort4LinkstsRemoteA | read-only | current | f2000EAS Series card Port4 link status: 0:Link down 1:Link up |
| 1.3.6.1.4.1.4756.20.731.20.1.90 | Columnf2000EASPort4SpeedstsRemoteA | read-only | current | f2000EAS Series card Port4 speed status |
| 1.3.6.1.4.1.4756.20.731.20.1.91 | Columnf2000EASPort4DuplexstsRemoteA | read-only | current | f2000EAS Series card Port4 duplex status 0: Half 1: Full |
| 1.3.6.1.4.1.4756.20.731.20.1.92 | Columnf2000EASPort4RxPausestsRemoteA | read-only | current | f2000EAS Series card Port4 rx pause status 0: No 1: Yes |
| 1.3.6.1.4.1.4756.20.731.20.1.93 | Columnf2000EASPort4TxPausestsRemoteA | read-only | current | f2000EAS Series card Port4 tx pause status 0: No 1: Yes |
| 1.3.6.1.4.1.4756.20.731.20.1.94 | Columnf2000EASPort1SpeedConfRemoteA | read-write | current | f2000EAS Series card Port1 speed config 0: disable 1: auto 2: 100M FDX 3: 1G FDX |
| 1.3.6.1.4.1.4756.20.731.20.1.95 | Columnf2000EASPort1flowConrolRemoteA | read-write | current | f2000EAS Series card Port1 flow control config 0: no 1: yes |
| 1.3.6.1.4.1.4756.20.731.20.1.96 | Columnf2000EASPort1MaxFrameRemoteA | read-write | current | f2000EAS Series card Port1 max frame config |
| 1.3.6.1.4.1.4756.20.731.20.1.97 | Columnf2000EASPort1ALSRemoteA | read-write | current | f2000EAS Series card Port1 auto laser shutdown: 0: Disable 1: Enable |
| 1.3.6.1.4.1.4756.20.731.20.1.98 | Columnf2000EASPort1FrameLengthCheckRemoteA | read-write | current | f2000EAS Series card Port1 Frame Length Check config 0: no 1: yes |
| 1.3.6.1.4.1.4756.20.731.20.1.99 | Columnf2000EASPort2SpeedConfRemoteA | read-write | current | f2000EAS Series card Port2 speed config 0: disable 1: auto 2: 100M FDX 3: 1G FDX |
| 1.3.6.1.4.1.4756.20.731.20.1.100 | Columnf2000EASPort2flowConrolRemoteA | read-write | current | f2000EAS Series card Port2 flow control config 0: no 1: yes |
| 1.3.6.1.4.1.4756.20.731.20.1.101 | Columnf2000EASPort2MaxFrameRemoteA | read-write | current | f2000EAS Series card Port2 max frame config |
| 1.3.6.1.4.1.4756.20.731.20.1.102 | Columnf2000EASPort2ALSRemoteA | read-write | current | f2000EAS Series card Port2 auto laser shutdown: 0: Disable 1: Enable |
| 1.3.6.1.4.1.4756.20.731.20.1.103 | Columnf2000EASPort2FrameLengthCheckRemoteA | read-write | current | f2000EAS Series card Port2 Frame Length Check config 0: no 1: yes |
| 1.3.6.1.4.1.4756.20.731.20.1.104 | Columnf2000EASPort3SpeedConfRemoteA | read-write | current | f2000EAS Series card Port3 speed config 0: disable 1: auto 2: 10M HDX 3: 10M FDX 4: 100M HDX 5: 100M FDX 6: 1G FDX |
| 1.3.6.1.4.1.4756.20.731.20.1.105 | Columnf2000EASPort3flowConrolRemoteA | read-write | current | f2000EAS Series card Port3 flow control config 0: no 1: yes |
| 1.3.6.1.4.1.4756.20.731.20.1.106 | Columnf2000EASPort3MaxFrameRemoteA | read-write | current | f2000EAS Series card Port3 max frame config |
| 1.3.6.1.4.1.4756.20.731.20.1.107 | Columnf2000EASPort3CollisionModeRemoteA | read-write | current | f2000EAS Series card Port3 collision mode config. 0: Discard 1: Restart |
| 1.3.6.1.4.1.4756.20.731.20.1.108 | Columnf2000EASPort3ALSRemoteA | read-write | current | f2000EAS Series card Port3 auto laser shutdown 0: Disable 1: Enable |
| 1.3.6.1.4.1.4756.20.731.20.1.109 | Columnf2000EASPort3FrameLengthCheckRemoteA | read-write | current | f2000EAS Series card Port3 Frame Length Check config 0: no 1: yes |
| 1.3.6.1.4.1.4756.20.731.20.1.110 | Columnf2000EASPort4SpeedConfRemoteA | read-write | current | f2000EAS Series card Port4 speed config 0: disable 1: auto 2: 10M HDX 3: 10M FDX 4: 100M HDX 5: 100M FDX 6: 1G FDX |
| 1.3.6.1.4.1.4756.20.731.20.1.111 | Columnf2000EASPort4flowConrolRemoteA | read-write | current | f2000EAS Series card Port4 flow control config 0: no 1: yes |
| 1.3.6.1.4.1.4756.20.731.20.1.112 | Columnf2000EASPort4MaxFrameRemoteA | read-write | current | f2000EAS Series card Port4 max frame config |
| 1.3.6.1.4.1.4756.20.731.20.1.113 | Columnf2000EASPort4CollisionModeRemoteA | read-write | current | f2000EAS Series card Port4 collision mode config 0: Discard 1: Restart |
| 1.3.6.1.4.1.4756.20.731.20.1.114 | Columnf2000EASPort4ALSRemoteA | read-write | current | f2000EAS Series card Port4 auto laser shutdown 0: Disable 1: Enable |
| 1.3.6.1.4.1.4756.20.731.20.1.115 | Columnf2000EASPort4FrameLengthCheckRemoteA | read-write | current | f2000EAS Series card Port4 Frame Length Check config 0: no 1: yes |
| 1.3.6.1.4.1.4756.20.731.20.1.116 | Columnf2000EASPort1AdvDuplexHdxRemoteA | read-write | current | f2000EAS Series card Port1 Adv Dpulex Hdx 0: OFF 1: ON |
| 1.3.6.1.4.1.4756.20.731.20.1.117 | Columnf2000EASPort1AdvDuplexFdxRemoteA | read-write | current | f2000EAS Series card Port1 Adv Dpulex Fdx 0: OFF 1: ON |
| 1.3.6.1.4.1.4756.20.731.20.1.118 | Columnf2000EASPort1AdvSpeed10MRemoteA | read-write | current | f2000EAS Series card Port1 Adv Speed 10M 0: OFF 1: ON |
| 1.3.6.1.4.1.4756.20.731.20.1.119 | Columnf2000EASPort1AdvSpeed100MRemoteA | read-write | current | f2000EAS Series card Port1 Adv Speed 100M 0: OFF 1: ON |
| 1.3.6.1.4.1.4756.20.731.20.1.120 | Columnf2000EASPort1AdvSpeed1GRemoteA | read-write | current | f2000EAS Series card Port1 Adv Speed 1G 0: OFF 1: ON |
| 1.3.6.1.4.1.4756.20.731.20.1.121 | Columnf2000EASPort2AdvDuplexHdxRemoteA | read-write | current | f2000EAS Series card Port2 Adv Dpulex Hdx 0: OFF 1: ON |
| 1.3.6.1.4.1.4756.20.731.20.1.122 | Columnf2000EASPort2AdvDuplexFdxRemoteA | read-write | current | f2000EAS Series card Port2 Adv Dpulex Fdx 0: OFF 1: ON |
| 1.3.6.1.4.1.4756.20.731.20.1.123 | Columnf2000EASPort2AdvSpeed10MRemoteA | read-write | current | f2000EAS Series card Port2 Adv Speed 10M 0: OFF 1: ON |
| 1.3.6.1.4.1.4756.20.731.20.1.124 | Columnf2000EASPort2AdvSpeed100MRemoteA | read-write | current | f2000EAS Series card Port2 Adv Speed 100M 0: OFF 1: ON |
| 1.3.6.1.4.1.4756.20.731.20.1.125 | Columnf2000EASPort2AdvSpeed1GRemoteA | read-write | current | f2000EAS Series card Port2 Adv Speed 1G 0: OFF 1: ON |
| 1.3.6.1.4.1.4756.20.731.20.1.126 | Columnf2000EASPort3AdvDuplexHdxRemoteA | read-write | current | f2000EAS Series card Port3 Adv Dpulex Hdx 0: OFF 1: ON |
| 1.3.6.1.4.1.4756.20.731.20.1.127 | Columnf2000EASPort3AdvDuplexFdxRemoteA | read-write | current | f2000EAS Series card Port3 Adv Dpulex Fdx 0: OFF 1: ON |
| 1.3.6.1.4.1.4756.20.731.20.1.128 | Columnf2000EASPort3AdvSpeed10MRemoteA | read-write | current | f2000EAS Series card Port3 Adv Speed 10M 0: OFF 1: ON |
| 1.3.6.1.4.1.4756.20.731.20.1.129 | Columnf2000EASPort3AdvSpeed100MRemoteA | read-write | current | f2000EAS Series card Port3 Adv Speed 100M 0: OFF 1: ON |
| 1.3.6.1.4.1.4756.20.731.20.1.130 | Columnf2000EASPort3AdvSpeed1GRemoteA | read-write | current | f2000EAS Series card Port3 Adv Speed 1G 0: OFF 1: ON |
| 1.3.6.1.4.1.4756.20.731.20.1.131 | Columnf2000EASPort4AdvDuplexHdxRemoteA | read-write | current | f2000EAS Series card Port4 Adv Dpulex Hdx 0: OFF 1: ON |
| 1.3.6.1.4.1.4756.20.731.20.1.132 | Columnf2000EASPort4AdvDuplexFdxRemoteA | read-write | current | f2000EAS Series card Port4 Adv Dpulex Fdx 0: OFF 1: ON |
| 1.3.6.1.4.1.4756.20.731.20.1.133 | Columnf2000EASPort4AdvSpeed10MRemoteA | read-write | current | f2000EAS Series card Port4 Adv Speed 10M 0: OFF 1: ON |
| 1.3.6.1.4.1.4756.20.731.20.1.134 | Columnf2000EASPort4AdvSpeed100MRemoteA | read-write | current | f2000EAS Series card Port4 Adv Speed 100M 0: OFF 1: ON |
| 1.3.6.1.4.1.4756.20.731.20.1.135 | Columnf2000EASPort4AdvSpeed1GRemoteA | read-write | current | f2000EAS Series card Port4 Adv Speed 1G 0: OFF 1: ON |
| 1.3.6.1.4.1.4756.20.731.20.1.136 | Columnf2000EASPortResetRemoteA | read-write | current | f2000EAS Series card port reset 0: OFF 1: Action |
| 1.3.6.1.4.1.4756.20.731.20.1.137 | Columnf2000EASSetDefaultRemoteA | read-write | current | f2000EAS Series card set to default config 0: OFF 1: Action |
| 1.3.6.1.4.1.4756.20.731.20.1.138 | Columnf2000EASPort1PacketsRxRemoteA | read-only | current | f2000EAS Series card port1 traffic overview:: Packets Rx |
| 1.3.6.1.4.1.4756.20.731.20.1.139 | Columnf2000EASPort1PacketsTxRemoteA | read-only | current | f2000EAS Series card port1 traffic overview:: Packets Tx |
| 1.3.6.1.4.1.4756.20.731.20.1.140 | Columnf2000EASPort1BytesRxRemoteA | read-only | current | f2000EAS Series card port1 traffic overview:: Bytes Rx |
| 1.3.6.1.4.1.4756.20.731.20.1.141 | Columnf2000EASPort1BytesTxRemoteA | read-only | current | f2000EAS Series card port1 traffic overview:: Bytes Tx |
| 1.3.6.1.4.1.4756.20.731.20.1.142 | Columnf2000EASPort1ErrorsRxRemoteA | read-only | current | f2000EAS Series card port1 traffic overview:: Errors Rx |
| 1.3.6.1.4.1.4756.20.731.20.1.143 | Columnf2000EASPort1ErrorsTxRemoteA | read-only | current | f2000EAS Series card port1 traffic overview:: Errors Tx |
| 1.3.6.1.4.1.4756.20.731.20.1.144 | Columnf2000EASPort1DropsRxRemoteA | read-only | current | f2000EAS Series card port1 traffic overview:: Drops Rx |
| 1.3.6.1.4.1.4756.20.731.20.1.145 | Columnf2000EASPort1DropsTxRemoteA | read-only | current | f2000EAS Series card port1 traffic overview:: Drops Tx |
| 1.3.6.1.4.1.4756.20.731.20.1.146 | Columnf2000EASPort1FilteredRxRemoteA | read-only | current | f2000EAS Series card port1 traffic overview:: Filtered Rx |
| 1.3.6.1.4.1.4756.20.731.20.1.147 | Columnf2000EASPort2PacketsRxRemoteA | read-only | current | f2000EAS Series card port2 traffic overview:: Packets Rx |
| 1.3.6.1.4.1.4756.20.731.20.1.148 | Columnf2000EASPort2PacketsTxRemoteA | read-only | current | f2000EAS Series card port2 traffic overview:: Packets Tx |
| 1.3.6.1.4.1.4756.20.731.20.1.149 | Columnf2000EASPort2BytesRxRemoteA | read-only | current | f2000EAS Series card port2 traffic overview:: Bytes Rx |
| 1.3.6.1.4.1.4756.20.731.20.1.150 | Columnf2000EASPort2BytesTxRemoteA | read-only | current | f2000EAS Series card port2 traffic overview:: Bytes Tx |
| 1.3.6.1.4.1.4756.20.731.20.1.151 | Columnf2000EASPort2ErrorsRxRemoteA | read-only | current | f2000EAS Series card port2 traffic overview:: Errors Rx |
| 1.3.6.1.4.1.4756.20.731.20.1.152 | Columnf2000EASPort2ErrorsTxRemoteA | read-only | current | f2000EAS Series card port2 traffic overview:: Errors Tx |
| 1.3.6.1.4.1.4756.20.731.20.1.153 | Columnf2000EASPort2DropsRxRemoteA | read-only | current | f2000EAS Series card port2 traffic overview:: Drops Rx |
| 1.3.6.1.4.1.4756.20.731.20.1.154 | Columnf2000EASPort2DropsTxRemoteA | read-only | current | f2000EAS Series card port2 traffic overview:: Drops Tx |
| 1.3.6.1.4.1.4756.20.731.20.1.155 | Columnf2000EASPort2FilteredRxRemoteA | read-only | current | f2000EAS Series card port2 traffic overview:: Filtered Rx |
| 1.3.6.1.4.1.4756.20.731.20.1.156 | Columnf2000EASPort3PacketsRxRemoteA | read-only | current | f2000EAS Series card port3 traffic overview:: Packets Rx |
| 1.3.6.1.4.1.4756.20.731.20.1.157 | Columnf2000EASPort3PacketsTxRemoteA | read-only | current | f2000EAS Series card port3 traffic overview:: Packets Tx |
| 1.3.6.1.4.1.4756.20.731.20.1.158 | Columnf2000EASPort3BytesRxRemoteA | read-only | current | f2000EAS Series card port3 traffic overview:: Bytes Rx |
| 1.3.6.1.4.1.4756.20.731.20.1.159 | Columnf2000EASPort3BytesTxRemoteA | read-only | current | f2000EAS Series card port3 traffic overview:: Bytes Tx |
| 1.3.6.1.4.1.4756.20.731.20.1.160 | Columnf2000EASPort3ErrorsRxRemoteA | read-only | current | f2000EAS Series card port3 traffic overview:: Errors Rx |
| 1.3.6.1.4.1.4756.20.731.20.1.161 | Columnf2000EASPort3ErrorsTxRemoteA | read-only | current | f2000EAS Series card port3 traffic overview:: Errors Tx |
| 1.3.6.1.4.1.4756.20.731.20.1.162 | Columnf2000EASPort3DropsRxRemoteA | read-only | current | f2000EAS Series card port3 traffic overview:: Drops Rx |
| 1.3.6.1.4.1.4756.20.731.20.1.163 | Columnf2000EASPort3DropsTxRemoteA | read-only | current | f2000EAS Series card port3 traffic overview:: Drops Tx |
| 1.3.6.1.4.1.4756.20.731.20.1.164 | Columnf2000EASPort3FilteredRxRemoteA | read-only | current | f2000EAS Series card port3 traffic overview:: Filtered Rx |
| 1.3.6.1.4.1.4756.20.731.20.1.165 | Columnf2000EASPort4PacketsRxRemoteA | read-only | current | f2000EAS Series card port4 traffic overview:: Packets Rx |
| 1.3.6.1.4.1.4756.20.731.20.1.166 | Columnf2000EASPort4PacketsTxRemoteA | read-only | current | f2000EAS Series card port4 traffic overview:: Packets Tx |
| 1.3.6.1.4.1.4756.20.731.20.1.167 | Columnf2000EASPort4BytesRxRemoteA | read-only | current | f2000EAS Series card port4 traffic overview:: Bytes Rx |
| 1.3.6.1.4.1.4756.20.731.20.1.168 | Columnf2000EASPort4BytesTxRemoteA | read-only | current | f2000EAS Series card port4 traffic overview:: Bytes Tx |
| 1.3.6.1.4.1.4756.20.731.20.1.169 | Columnf2000EASPort4ErrorsRxRemoteA | read-only | current | f2000EAS Series card port4 traffic overview:: Errors Rx |
| 1.3.6.1.4.1.4756.20.731.20.1.170 | Columnf2000EASPort4ErrorsTxRemoteA | read-only | current | f2000EAS Series card port4 traffic overview:: Errors Tx |
| 1.3.6.1.4.1.4756.20.731.20.1.171 | Columnf2000EASPort4DropsRxRemoteA | read-only | current | f2000EAS Series card port4 traffic overview:: Drops Rx |
| 1.3.6.1.4.1.4756.20.731.20.1.172 | Columnf2000EASPort4DropsTxRemoteA | read-only | current | f2000EAS Series card port4 traffic overview:: Drops Tx |
| 1.3.6.1.4.1.4756.20.731.20.1.173 | Columnf2000EASPort4FilteredRxRemoteA | read-only | current | f2000EAS Series card port4 traffic overview:: Filtered Rx |
| 1.3.6.1.4.1.4756.20.731.20.1.174 | Columnf2000EASDeviceActiveRemoteA | read-only | current | f2000EAS Series card device active 0: Disable 1: Enable |
| 1.3.6.1.4.1.4756.20.731.20.1.175 | Columnf2000EASFx1DDRemoteA | read-only | current | f2000EAS Series card fiber1 port Digital Diagnostic function: 0:No 1:Yes |
| 1.3.6.1.4.1.4756.20.731.20.1.176 | Columnf2000EASFx1DDVendorRemoteA | read-only | current | f2000EAS Series card fiber1 port D/D information: Vendor name |
| 1.3.6.1.4.1.4756.20.731.20.1.177 | Columnf2000EASFx1DDPartNoRemoteA | read-only | current | f2000EAS Series card fiber1 port D/D information: Vendor part number |
| 1.3.6.1.4.1.4756.20.731.20.1.178 | Columnf2000EASFx1DDFiberTypeRemoteA | read-only | current | f2000EAS Series card fiber1 port D/D information: Fiber Type |
| 1.3.6.1.4.1.4756.20.731.20.1.179 | Columnf2000EASFx1DDWaveLenRemoteA | read-only | current | f2000EAS Series card fiber1 port D/D information: Wave length |
| 1.3.6.1.4.1.4756.20.731.20.1.180 | Columnf2000EASFx1DDWaveLen2RemoteA | read-only | current | f2000EAS Series card fiber1 port D/D information: Wave length 2 |
| 1.3.6.1.4.1.4756.20.731.20.1.181 | Columnf2000EASFx1DDLinkLenRemoteA | read-only | current | f2000EAS Series card fiber1 port D/D information: Link length |
| 1.3.6.1.4.1.4756.20.731.20.1.182 | Columnf2000EASFx1DDLenUnitRemoteA | read-only | current | f2000EAS Series card fiber1 port D/D information: Length Unit |
| 1.3.6.1.4.1.4756.20.731.20.1.183 | Columnf2000EASFx1DDStatusRemoteA | read-only | current | f2000EAS Series card fiber1 port D/D information: Status Support |
| 1.3.6.1.4.1.4756.20.731.20.1.184 | Columnf2000EASFx1DDRxSensRemoteA | read-only | current | f2000EAS Series card fiber1 port D/D information: Rx Sensitivity |
| 1.3.6.1.4.1.4756.20.731.20.1.185 | Columnf2000EASFx1DDTxPWRRemoteA | read-only | current | f2000EAS Series card fiber1 port D/D information: Tx power |
| 1.3.6.1.4.1.4756.20.731.20.1.186 | Columnf2000EASFx1DDRxPWRRemoteA | read-only | current | f2000EAS Series card fiber1 port D/D information: Rx power |
| 1.3.6.1.4.1.4756.20.731.20.1.187 | Columnf2000EASFx1DDTempRemoteA | read-only | current | f2000EAS Series card fiber1 port D/D information: Temperature in degree C |
| 1.3.6.1.4.1.4756.20.731.20.1.188 | Columnf2000EASFx1DDPWRMarginRemoteA | read-only | current | f2000EAS Series card fiber1 port D/D information: Power margin |
| 1.3.6.1.4.1.4756.20.731.20.1.189 | Columnf2000EASFx1DDPWRLossRemoteA | read-only | current | f2000EAS Series card fiber1 port D/D information: Power loss |
| 1.3.6.1.4.1.4756.20.731.20.1.190 | Columnf2000EASFx2DDRemoteA | read-only | current | f2000EAS Series card fiber2 Digital Diagnostic function: 0:NO 1:Yes |
| 1.3.6.1.4.1.4756.20.731.20.1.191 | Columnf2000EASFx2DDVendorRemoteA | read-only | current | f2000EAS Series card fiber2 D/D information: Vendor name |
| 1.3.6.1.4.1.4756.20.731.20.1.192 | Columnf2000EASFx2DDPartNoRemoteA | read-only | current | f2000EAS Series card fiber2 D/D information: Vendor part number |
| 1.3.6.1.4.1.4756.20.731.20.1.193 | Columnf2000EASFx2DDFiberTypeRemoteA | read-only | current | f2000EAS Series card fiber2 D/D information: Fiber Type |
| 1.3.6.1.4.1.4756.20.731.20.1.194 | Columnf2000EASFx2DDWaveLenRemoteA | read-only | current | f2000EAS Series card fiber2 D/D information: Wave length 1 |
| 1.3.6.1.4.1.4756.20.731.20.1.195 | Columnf2000EASFx2DDWaveLen2RemoteA | read-only | current | f2000EAS Series card fiber2 D/D information: Wave length 2 |
| 1.3.6.1.4.1.4756.20.731.20.1.196 | Columnf2000EASFx2DDLinkLenRemoteA | read-only | current | f2000EAS Series card fiber2 D/D information: Link length |
| 1.3.6.1.4.1.4756.20.731.20.1.197 | Columnf2000EASFx2DDLenUnitRemoteA | read-only | current | f2000EAS Series card fiber2 D/D information: Length Unit |
| 1.3.6.1.4.1.4756.20.731.20.1.198 | Columnf2000EASFx2DDStatusRemoteA | read-only | current | f2000EAS Series card fiber2 D/D information: Status Support |
| 1.3.6.1.4.1.4756.20.731.20.1.199 | Columnf2000EASFx2DDRxSensRemoteA | read-only | current | f2000EAS Series card fiber2 D/D information: Rx Sensitivity |
| 1.3.6.1.4.1.4756.20.731.20.1.200 | Columnf2000EASFx2DDTxPWRRemoteA | read-only | current | f2000EAS Series card fiber2 D/D information: Tx power |
| 1.3.6.1.4.1.4756.20.731.20.1.201 | Columnf2000EASFx2DDRxPWRRemoteA | read-only | current | f2000EAS Series card fiber2 D/D information: Rx power |
| 1.3.6.1.4.1.4756.20.731.20.1.202 | Columnf2000EASFx2DDTempRemoteA | read-only | current | f2000EAS Series card fiber2 D/D information: Temperature in degree C |
| 1.3.6.1.4.1.4756.20.731.20.1.203 | Columnf2000EASFx2DDPWRMarginRemoteA | read-only | current | f2000EAS Series card fiber2 D/D information: Power margin |
| 1.3.6.1.4.1.4756.20.731.20.1.204 | Columnf2000EASFx2DDPWRLossRemoteA | read-only | current | f2000EAS Series card fiber2 D/D information: Power loss |
| 1.3.6.1.4.1.4756.20.731.20.1.205 | Columnf2000EASFx3DDRemoteA | read-only | current | f2000EAS Series card fiber3 Digital Diagnostic function: 0:NO 1:Yes |
| 1.3.6.1.4.1.4756.20.731.20.1.206 | Columnf2000EASFx3DDVendorRemoteA | read-only | current | f2000EAS Series card fiber3 D/D information: Vendor name |
| 1.3.6.1.4.1.4756.20.731.20.1.207 | Columnf2000EASFx3DDPartNoRemoteA | read-only | current | f2000EAS Series card fiber32 D/D information: Vendor part number |
| 1.3.6.1.4.1.4756.20.731.20.1.208 | Columnf2000EASFx3DDFiberTypeRemoteA | read-only | current | f2000EAS Series card fiber3 D/D information: Fiber Type |
| 1.3.6.1.4.1.4756.20.731.20.1.209 | Columnf2000EASFx3DDWaveLenRemoteA | read-only | current | f2000EAS Series card fiber3 D/D information: Wave length 1 |
| 1.3.6.1.4.1.4756.20.731.20.1.210 | Columnf2000EASFx3DDWaveLen2RemoteA | read-only | current | f2000EAS Series card fiber3 D/D information: Wave length 2 |
| 1.3.6.1.4.1.4756.20.731.20.1.211 | Columnf2000EASFx3DDLinkLenRemoteA | read-only | current | f2000EAS Series card fiber3 D/D information: Link length |
| 1.3.6.1.4.1.4756.20.731.20.1.212 | Columnf2000EASFx3DDLenUnitRemoteA | read-only | current | f2000EAS Series card fiber3 D/D information: Length Unit |
| 1.3.6.1.4.1.4756.20.731.20.1.213 | Columnf2000EASFx3DDStatusRemoteA | read-only | current | f2000EAS Series card fiber3 D/D information: Status Support |
| 1.3.6.1.4.1.4756.20.731.20.1.214 | Columnf2000EASFx3DDRxSensRemoteA | read-only | current | f2000EAS Series card fiber3 D/D information: Rx Sensitivity |
| 1.3.6.1.4.1.4756.20.731.20.1.215 | Columnf2000EASFx3DDTxPWRRemoteA | read-only | current | f2000EAS Series card fiber3 D/D information: Tx power |
| 1.3.6.1.4.1.4756.20.731.20.1.216 | Columnf2000EASFx3DDRxPWRRemoteA | read-only | current | f2000EAS Series card fiber3 D/D information: Rx power |
| 1.3.6.1.4.1.4756.20.731.20.1.217 | Columnf2000EASFx3DDTempRemoteA | read-only | current | f2000EAS Series card fiber3 D/D information: Temperature in degree C |
| 1.3.6.1.4.1.4756.20.731.20.1.218 | Columnf2000EASFx3DDPWRMarginRemoteA | read-only | current | f2000EAS Series card fiber3 D/D information: Power margin |
| 1.3.6.1.4.1.4756.20.731.20.1.219 | Columnf2000EASFx3DDPWRLossRemoteA | read-only | current | f2000EAS Series card fiber3 D/D information: Power loss |
| 1.3.6.1.4.1.4756.20.731.20.1.220 | Columnf2000EASFx4DDRemoteA | read-only | current | f2000EAS Series card fiber4 Digital Diagnostic function: 0:NO 1:Yes |
| 1.3.6.1.4.1.4756.20.731.20.1.221 | Columnf2000EASFx4DDVendorRemoteA | read-only | current | f2000EAS Series card fiber4 D/D information: Vendor name |
| 1.3.6.1.4.1.4756.20.731.20.1.222 | Columnf2000EASFx4DDPartNoRemoteA | read-only | current | f2000EAS Series card fiber4 D/D information: Vendor part number |
| 1.3.6.1.4.1.4756.20.731.20.1.223 | Columnf2000EASFx4DDFiberTypeRemoteA | read-only | current | f2000EAS Series card fiber4 D/D information: Fiber Type |
| 1.3.6.1.4.1.4756.20.731.20.1.224 | Columnf2000EASFx4DDWaveLenRemoteA | read-only | current | f2000EAS Series card fiber4 D/D information: Wave length 1 |
| 1.3.6.1.4.1.4756.20.731.20.1.225 | Columnf2000EASFx4DDWaveLen2RemoteA | read-only | current | f2000EAS Series card fiber4 D/D information: Wave length 2 |
| 1.3.6.1.4.1.4756.20.731.20.1.226 | Columnf2000EASFx4DDLinkLenRemoteA | read-only | current | f2000EAS Series card fiber4 D/D information: Link length |
| 1.3.6.1.4.1.4756.20.731.20.1.227 | Columnf2000EASFx4DDLenUnitRemoteA | read-only | current | f2000EAS Series card fiber4 D/D information: Length Unit |
| 1.3.6.1.4.1.4756.20.731.20.1.228 | Columnf2000EASFx4DDStatusRemoteA | read-only | current | f2000EAS Series card fiber4 D/D information: Status Support |
| 1.3.6.1.4.1.4756.20.731.20.1.229 | Columnf2000EASFx4DDRxSensRemoteA | read-only | current | f2000EAS Series card fiber4 D/D information: Rx Sensitivity |
| 1.3.6.1.4.1.4756.20.731.20.1.230 | Columnf2000EASFx4DDTxPWRRemoteA | read-only | current | f2000EAS Series card fiber4 D/D information: Tx power |
| 1.3.6.1.4.1.4756.20.731.20.1.231 | Columnf2000EASFx4DDRxPWRRemoteA | read-only | current | f2000EAS Series card fiber4 D/D information: Rx power |
| 1.3.6.1.4.1.4756.20.731.20.1.232 | Columnf2000EASFx4DDTempRemoteA | read-only | current | f2000EAS Series card fiber4 D/D information: Temperature in degree C |
| 1.3.6.1.4.1.4756.20.731.20.1.233 | Columnf2000EASFx4DDPWRMarginRemoteA | read-only | current | f2000EAS Series card fiber4 D/D information: Power margin |
| 1.3.6.1.4.1.4756.20.731.20.1.234 | Columnf2000EASFx4DDPWRLossRemoteA | read-only | current | f2000EAS Series card fiber4 D/D information: Power loss |
| 1.3.6.1.4.1.4756.20.731.20.1.235 | Columnf2000EASTestRemoteA | read-only | current | f2000EAS Series card test led sts: 0: Off 1: On |
| 1.3.6.1.4.1.4756.20.731.20.1.236 | Columnf2000EASClearPortCounterRemoteA | read-write | current | f2000EAS Series card clear port counter: 0: Off 1: Action |
| 1.3.6.1.4.1.4756.20.731.20.1.237 | Columnf2000EASAggrSourceMACAddrRemoteA | read-write | current | f2000EAS Series card Aggregation Mode Configuration: Source MAC Address 0: No 1: Yes |
| 1.3.6.1.4.1.4756.20.731.20.1.238 | Columnf2000EASAggrDestinationMACAddrRemoteA | read-write | current | f2000EAS Series card Aggregation Mode Configuration: Destination MAC Address 0: No 1: Yes |
| 1.3.6.1.4.1.4756.20.731.20.1.239 | Columnf2000EASAggrIPAddrRemoteA | read-write | current | f2000EAS Series card Aggregation Mode Configuration: IP Address 0: No 1: Yes |
| 1.3.6.1.4.1.4756.20.731.20.1.240 | Columnf2000EASAggrTCPUDPPortNumRemoteA | read-write | current | f2000EAS Series card Aggregation Mode Configuration: TCP/UDP Port Number 0: No 1: Yes |
| 1.3.6.1.4.1.4756.20.731.20.1.241 | Columnf2000EASAggrGroupPort1ConfRemoteA | read-write | current | f2000EAS Series card Aggregation Group Port1 Configuration: 0: Normal 1: ID1 2: ID2 |
| 1.3.6.1.4.1.4756.20.731.20.1.242 | Columnf2000EASAggrGroupPort2ConfRemoteA | read-write | current | f2000EAS Series card Aggregation Group Port2 Configuration: 0: Normal 1: ID1 2: ID2 |
| 1.3.6.1.4.1.4756.20.731.20.1.243 | Columnf2000EASAggrGroupPort3ConfRemoteA | read-write | current | f2000EAS Series card Aggregation Group Port3 Configuration: 0: Normal 1: ID1 2: ID2 |
| 1.3.6.1.4.1.4756.20.731.20.1.244 | Columnf2000EASAggrGroupPort4ConfRemoteA | read-write | current | f2000EAS Series card Aggregation Group Port4 Configuration: 0: Normal 1: ID1 2: ID2 |
| 1.3.6.1.4.1.4756.20.731.20.1.245 | Columnf2000EASPort1LACPEnabledRemoteA | read-write | current | f2000EAS Series card Port1 LACP Enabled: 0: No 1: Yes |
| 1.3.6.1.4.1.4756.20.731.20.1.246 | Columnf2000EASPort1LACPKEYRemoteA | read-write | current | f2000EAS Series card Port1 LACP Key value: The Key value incurred by the port, range 0-65535.The value of 0 means auto. |
| 1.3.6.1.4.1.4756.20.731.20.1.247 | Columnf2000EASPort1LACPRoleRemoteA | read-write | current | f2000EAS Series card Port1 LACP Role: 0: Passive 1: Active |
| 1.3.6.1.4.1.4756.20.731.20.1.248 | Columnf2000EASPort1LACPTimeOutRemoteA | read-write | current | f2000EAS Series card Port1 LACP Time out: 0: Slow 1: Fast |
| 1.3.6.1.4.1.4756.20.731.20.1.249 | Columnf2000EASPort1LACPPrioRemoteA | read-write | current | f2000EAS Series card Port1 LACP priority: The Key value incurred by the port, range 1-65535. |
| 1.3.6.1.4.1.4756.20.731.20.1.250 | Columnf2000EASPort2LACPEnabledRemoteA | read-write | current | f2000EAS Series card Port2 LACP Enabled: 0: No 1: Yes |
| 1.3.6.1.4.1.4756.20.731.20.1.251 | Columnf2000EASPort2LACPKEYRemoteA | read-write | current | f2000EAS Series card Port2 LACP Key value: The Key value incurred by the port, range 0-65535.The value of 0 means auto. |
| 1.3.6.1.4.1.4756.20.731.20.1.252 | Columnf2000EASPort2LACPRoleRemoteA | read-write | current | f2000EAS Series card Port2 LACP Role: 0: Passive 1: Active |
| 1.3.6.1.4.1.4756.20.731.20.1.253 | Columnf2000EASPort2LACPTimeOutRemoteA | read-write | current | f2000EAS Series card Port2 LACP Time out: 0: Slow 1: Fast |
| 1.3.6.1.4.1.4756.20.731.20.1.254 | Columnf2000EASPort2LACPPrioRemoteA | read-write | current | f2000EAS Series card Port2 LACP priority: The Key value incurred by the port, range 1-65535. |
| 1.3.6.1.4.1.4756.20.731.20.1.255 | Columnf2000EASPort3LACPEnabledRemoteA | read-write | current | f2000EAS Series card Port3 LACP Enabled: 0: No 1: Yes |
| 1.3.6.1.4.1.4756.20.731.20.1.256 | Columnf2000EASPort3LACPKEYRemoteA | read-write | current | f2000EAS Series card Port3 LACP Key value: The Key value incurred by the port, range 0-65535.The value of 0 means auto. |
| 1.3.6.1.4.1.4756.20.731.20.1.257 | Columnf2000EASPort3LACPRoleRemoteA | read-write | current | f2000EAS Series card Port3 LACP Role: 0: Passive 1: Active |
| 1.3.6.1.4.1.4756.20.731.20.1.258 | Columnf2000EASPort3LACPTimeOutRemoteA | read-write | current | f2000EAS Series card Port3 LACP Time out: 0: Slow 1: Fast |
| 1.3.6.1.4.1.4756.20.731.20.1.259 | Columnf2000EASPort3LACPPrioRemoteA | read-write | current | f2000EAS Series card Port3 LACP priority: The Key value incurred by the port, range 1-65535. |
| 1.3.6.1.4.1.4756.20.731.20.1.260 | Columnf2000EASPort4LACPEnabledRemoteA | read-write | current | f2000EAS Series card Port4 LACP Enabled: 0: No 1: Yes |
| 1.3.6.1.4.1.4756.20.731.20.1.261 | Columnf2000EASPort4LACPKEYRemoteA | read-write | current | f2000EAS Series card Port4 LACP Key value: The Key value incurred by the port, range 0-65535.The value of 0 means auto. |
| 1.3.6.1.4.1.4756.20.731.20.1.262 | Columnf2000EASPort4LACPRoleRemoteA | read-write | current | f2000EAS Series card Port4 LACP Role: 0: Passive 1: Active |
| 1.3.6.1.4.1.4756.20.731.20.1.263 | Columnf2000EASPort4LACPTimeOutRemoteA | read-write | current | f2000EAS Series card Port4 LACP Time out: 0: Slow 1: Fast |
| 1.3.6.1.4.1.4756.20.731.20.1.264 | Columnf2000EASPort4LACPPrioRemoteA | read-write | current | f2000EAS Series card Port4 LACP priority: The Key value incurred by the port, range 1-65535. |
| 1.3.6.1.4.1.4756.20.731.20.1.265 | Columnf2000EASPort1LACPstsRemoteA | read-only | current | f2000EAS Series card Port1 LACP status: 0: No 1: Yes 2: Standby |
| 1.3.6.1.4.1.4756.20.731.20.1.266 | Columnf2000EASPort1LACPKEYstsRemoteA | read-only | current | f2000EAS Series card Port1 LACP status: Key |
| 1.3.6.1.4.1.4756.20.731.20.1.267 | Columnf2000EASPort1LACPAggrIDstsRemoteA | read-only | current | f2000EAS Series card Port1 LACP status: Aggr ID |
| 1.3.6.1.4.1.4756.20.731.20.1.268 | Columnf2000EASPort1LACPParnterSysIDstsRemoteA | read-only | current | f2000EAS Series card Port1 LACP status: Parnter System ID |
| 1.3.6.1.4.1.4756.20.731.20.1.269 | Columnf2000EASPort1LACPParnterPortstsRemoteA | read-only | current | f2000EAS Series card Port1 LACP status: Parnter Port Status |
| 1.3.6.1.4.1.4756.20.731.20.1.270 | Columnf2000EASPort1LACPParnterProistsRemoteA | read-only | current | f2000EAS Series card Port1 LACP status: Parnter Priority |
| 1.3.6.1.4.1.4756.20.731.20.1.271 | Columnf2000EASPort2LACPstsRemoteA | read-only | current | f2000EAS Series card Port2 LACP status: 0: No 1: Yes 2: Standby |
| 1.3.6.1.4.1.4756.20.731.20.1.272 | Columnf2000EASPort2LACPKEYstsRemoteA | read-only | current | f2000EAS Series card Port2 LACP status: Key |
| 1.3.6.1.4.1.4756.20.731.20.1.273 | Columnf2000EASPort2LACPAggrIDstsRemoteA | read-only | current | f2000EAS Series card Port2 LACP status: Aggr ID |
| 1.3.6.1.4.1.4756.20.731.20.1.274 | Columnf2000EASPort2LACPParnterSysIDstsRemoteA | read-only | current | f2000EAS Series card Port2 LACP status: Parnter System ID |
| 1.3.6.1.4.1.4756.20.731.20.1.275 | Columnf2000EASPort2LACPParnterPortstsRemoteA | read-only | current | f2000EAS Series card Port2 LACP status: Parnter Port Status |
| 1.3.6.1.4.1.4756.20.731.20.1.276 | Columnf2000EASPort2LACPParnterProistsRemoteA | read-only | current | f2000EAS Series card Port2 LACP status: Parnter Priority |
| 1.3.6.1.4.1.4756.20.731.20.1.277 | Columnf2000EASPort3LACPstsRemoteA | read-only | current | f2000EAS Series card Port3 LACP status: 0: No 1: Yes 2: Standby |
| 1.3.6.1.4.1.4756.20.731.20.1.278 | Columnf2000EASPort3LACPKEYstsRemoteA | read-only | current | f2000EAS Series card Port3 LACP status: Key |
| 1.3.6.1.4.1.4756.20.731.20.1.279 | Columnf2000EASPort3LACPAggrIDstsRemoteA | read-only | current | f2000EAS Series card Port3 LACP status: Aggr ID |
| 1.3.6.1.4.1.4756.20.731.20.1.280 | Columnf2000EASPort3LACPParnterSysIDstsRemoteA | read-only | current | f2000EAS Series card Port3 LACP status: Parnter System ID |
| 1.3.6.1.4.1.4756.20.731.20.1.281 | Columnf2000EASPort3LACPParnterPortstsRemoteA | read-only | current | f2000EAS Series card Port3 LACP status: Parnter Port Status |
| 1.3.6.1.4.1.4756.20.731.20.1.282 | Columnf2000EASPort3LACPParnterProistsRemoteA | read-only | current | f2000EAS Series card Port3 LACP status: Parnter Priority |
| 1.3.6.1.4.1.4756.20.731.20.1.283 | Columnf2000EASPort4LACPstsRemoteA | read-only | current | f2000EAS Series card Port4 LACP status: 0: No 1: Yes 2: Standby |
| 1.3.6.1.4.1.4756.20.731.20.1.284 | Columnf2000EASPort4LACPKEYstsRemoteA | read-only | current | f2000EAS Series card Port4 LACP status: Key |
| 1.3.6.1.4.1.4756.20.731.20.1.285 | Columnf2000EASPort4LACPAggrIDstsRemoteA | read-only | current | f2000EAS Series card Port4 LACP status: Aggr ID |
| 1.3.6.1.4.1.4756.20.731.20.1.286 | Columnf2000EASPort4LACPParnterSysIDstsRemoteA | read-only | current | f2000EAS Series card Port4 LACP status: Parnter System ID |
| 1.3.6.1.4.1.4756.20.731.20.1.287 | Columnf2000EASPort4LACPParnterPortstsRemoteA | read-only | current | f2000EAS Series card Port4 LACP status: Parnter Port Status |
| 1.3.6.1.4.1.4756.20.731.20.1.288 | Columnf2000EASPort4LACPParnterProistsRemoteA | read-only | current | f2000EAS Series card Port4 LACP status: Parnter Priority |
| 1.3.6.1.4.1.4756.20.731.20.1.289 | Columnf2000EASOAMPort1EnableRemoteA | read-only | current | f2000EAS Series card Port1 OAM: 0: Off 1: On |
| 1.3.6.1.4.1.4756.20.731.20.1.290 | Columnf2000EASOAMPort1ModeRemoteA | read-write | current | f2000EAS Series card Port1 OAM: 0: Passive 1: Active |
| 1.3.6.1.4.1.4756.20.731.20.1.291 | Columnf2000EASOAMPort1LoopBackRemoteA | read-write | current | f2000EAS Series card Port1 OAM LoopBack: 0: Off 1: On |
| 1.3.6.1.4.1.4756.20.731.20.1.292 | Columnf2000EASOAMPort1LinkMonitorRemoteA | read-write | current | f2000EAS Series card Port1 OAM Link Monitor: 0: Off 1: On |
| 1.3.6.1.4.1.4756.20.731.20.1.293 | Columnf2000EASOAMPort1MIBRetrievalRemoteA | read-write | current | f2000EAS Series card Port1 OAM MIB Retrieval: 0: Off 1: On |
| 1.3.6.1.4.1.4756.20.731.20.1.294 | Columnf2000EASOAMPort1LoopBackOPRemoteA | read-only | current | f2000EAS Series card Port1 OAM LoopBack operation: 0: Off 1: On |
| 1.3.6.1.4.1.4756.20.731.20.1.295 | Columnf2000EASOAMPort2EnableRemoteA | read-only | current | f2000EAS Series card Port2 OAM: 0: Off 1: On |
| 1.3.6.1.4.1.4756.20.731.20.1.296 | Columnf2000EASOAMPort2ModeRemoteA | read-write | current | f2000EAS Series card Port2 OAM: 0: Passive 1: Active |
| 1.3.6.1.4.1.4756.20.731.20.1.297 | Columnf2000EASOAMPort2LoopBackRemoteA | read-write | current | f2000EAS Series card Port2 OAM LoopBack: 0: Off 1: On |
| 1.3.6.1.4.1.4756.20.731.20.1.298 | Columnf2000EASOAMPort2LinkMonitorRemoteA | read-write | current | f2000EAS Series card Port2 OAM Link Monitor: 0: Off 1: On |
| 1.3.6.1.4.1.4756.20.731.20.1.299 | Columnf2000EASOAMPort2MIBRetrievalRemoteA | read-write | current | f2000EAS Series card Port2 OAM MIB Retrieval: 0: Off 1: On |
| 1.3.6.1.4.1.4756.20.731.20.1.300 | Columnf2000EASOAMPort2LoopBackOPRemoteA | read-only | current | f2000EAS Series card Port2 OAM LoopBack operation: 0: Off 1: On |
| 1.3.6.1.4.1.4756.20.731.20.1.301 | Columnf2000EASOAMPort3EnableRemoteA | read-only | current | f2000EAS Series card Port3 OAM: 0: Off 1: On |
| 1.3.6.1.4.1.4756.20.731.20.1.302 | Columnf2000EASOAMPort3ModeRemoteA | read-write | current | f2000EAS Series card Port3 OAM: 0: Passive 1: Active |
| 1.3.6.1.4.1.4756.20.731.20.1.303 | Columnf2000EASOAMPort3LoopBackRemoteA | read-write | current | f2000EAS Series card Port3 OAM: 0: Off 1: On |
| 1.3.6.1.4.1.4756.20.731.20.1.304 | Columnf2000EASOAMPort3LinkMonitorRemoteA | read-write | current | f2000EAS Series card Port3 OAM Link Monitor: 0: Off 1: On |
| 1.3.6.1.4.1.4756.20.731.20.1.305 | Columnf2000EASOAMPort3MIBRetrievalRemoteA | read-write | current | f2000EAS Series card Port3 OAM MIB Retrieval: 0: Off 1: On |
| 1.3.6.1.4.1.4756.20.731.20.1.306 | Columnf2000EASOAMPort3LoopBackOPRemoteA | read-only | current | f2000EAS Series card Port3 OAM LoopBack operation: 0: Disable 1: Enable |
| 1.3.6.1.4.1.4756.20.731.20.1.307 | Columnf2000EASOAMPort4EnableRemoteA | read-only | current | f2000EAS Series card Port4 OAM: 0: Off 1: On |
| 1.3.6.1.4.1.4756.20.731.20.1.308 | Columnf2000EASOAMPort4ModeRemoteA | read-write | current | f2000EAS Series card Port4 OAM: 0: Passive 1: Active |
| 1.3.6.1.4.1.4756.20.731.20.1.309 | Columnf2000EASOAMPort4LoopBackRemoteA | read-write | current | f2000EAS Series card Port4 OAM: 0: Off 1: On |
| 1.3.6.1.4.1.4756.20.731.20.1.310 | Columnf2000EASOAMPort4LinkMonitorRemoteA | read-write | current | f2000EAS Series card Port4 OAM Link Monitor: 0: Off 1: On |
| 1.3.6.1.4.1.4756.20.731.20.1.311 | Columnf2000EASOAMPort4MIBRetrievalRemoteA | read-write | current | f2000EAS Series card Port4 OAM MIB Retrieval: 0: Off 1: On |
| 1.3.6.1.4.1.4756.20.731.20.1.312 | Columnf2000EASOAMPort4LoopBackOPRemoteA | read-only | current | f2000EAS Series card Port4 OAM LoopBack operation: 0: On 1: Off |
| 1.3.6.1.4.1.4756.20.731.20.1.313 | Columnf2000EASPort1EFEErrorWindowRemoteA | read-write | current | f2000EAS Series card Port1 Link Event Configuration: Error Frame Event - Error Window |
| 1.3.6.1.4.1.4756.20.731.20.1.314 | Columnf2000EASPort1EFEErrorThresholdRemoteA | read-write | current | f2000EAS Series card Port1 Link Event Configuration: Error Frame Event - Error Threshold |
| 1.3.6.1.4.1.4756.20.731.20.1.315 | Columnf2000EASPort1SPEEErrorWindowRemoteA | read-write | current | f2000EAS Series card Port1 Link Event Configuration: Symbol Period Error Event - Error Window |
| 1.3.6.1.4.1.4756.20.731.20.1.316 | Columnf2000EASPort1SPEEErrorThresholdRemoteA | read-write | current | f2000EAS Series card Port1 Link Event Configuration: Symbol Period Error Event - Error Threshold |
| 1.3.6.1.4.1.4756.20.731.20.1.317 | Columnf2000EASPort1SSEErrorWindowRemoteA | read-write | current | f2000EAS Series card Port1 Link Event Configuration: Seconds Summary Event - Error Window |
| 1.3.6.1.4.1.4756.20.731.20.1.318 | Columnf2000EASPort1SSEErrorThresholdRemoteA | read-write | current | f2000EAS Series card Port1 Link Event Configuration: Seconds Summary Event - Error Threshold |
| 1.3.6.1.4.1.4756.20.731.20.1.319 | Columnf2000EASPort2EFEErrorWindowRemoteA | read-write | current | f2000EAS Series card Port2 Link Event Configuration: Error Frame Event - Error Window |
| 1.3.6.1.4.1.4756.20.731.20.1.320 | Columnf2000EASPort2EFEErrorThresholdRemoteA | read-write | current | f2000EAS Series card Port2 Link Event Configuration: Error Frame Event - Error Threshold |
| 1.3.6.1.4.1.4756.20.731.20.1.321 | Columnf2000EASPort2SPEEErrorWindowRemoteA | read-write | current | f2000EAS Series card Port2 Link Event Configuration: Symbol Period Error Event - Error Window |
| 1.3.6.1.4.1.4756.20.731.20.1.322 | Columnf2000EASPort2SPEEErrorThresholdRemoteA | read-write | current | f2000EAS Series card Port2 Link Event Configuration: Symbol Period Error Event - Error Threshold |
| 1.3.6.1.4.1.4756.20.731.20.1.323 | Columnf2000EASPort2SSEErrorWindowRemoteA | read-write | current | f2000EAS Series card Port2 Link Event Configuration: Seconds Summary Event - Error Window |
| 1.3.6.1.4.1.4756.20.731.20.1.324 | Columnf2000EASPort2SSEErrorThresholdRemoteA | read-write | current | f2000EAS Series card Port2 Link Event Configuration: Seconds Summary Event - Error Threshold |
| 1.3.6.1.4.1.4756.20.731.20.1.325 | Columnf2000EASPort3EFEErrorWindowRemoteA | read-write | current | f2000EAS Series card Port3 Link Event Configuration: Error Frame Event - Error Window |
| 1.3.6.1.4.1.4756.20.731.20.1.326 | Columnf2000EASPort3EFEErrorThresholdRemoteA | read-write | current | f2000EAS Series card Port3 Link Event Configuration: Error Frame Event - Error Threshold |
| 1.3.6.1.4.1.4756.20.731.20.1.327 | Columnf2000EASPort3SPEEErrorWindowRemoteA | read-write | current | f2000EAS Series card Port3 Link Event Configuration: Symbol Period Error Event - Error Window |
| 1.3.6.1.4.1.4756.20.731.20.1.328 | Columnf2000EASPort3SPEEErrorThresholdRemoteA | read-write | current | f2000EAS Series card Port3 Link Event Configuration: Symbol Period Error Event - Error Threshold |
| 1.3.6.1.4.1.4756.20.731.20.1.329 | Columnf2000EASPort3SSEErrorWindowRemoteA | read-write | current | f2000EAS Series card Port3 Link Event Configuration: Seconds Summary Event - Error Window |
| 1.3.6.1.4.1.4756.20.731.20.1.330 | Columnf2000EASPort3SSEErrorThresholdRemoteA | read-write | current | f2000EAS Series card Port3 Link Event Configuration: Seconds Summary Event - Error Threshold |
| 1.3.6.1.4.1.4756.20.731.20.1.331 | Columnf2000EASPort4EFEErrorWindowRemoteA | read-write | current | f2000EAS Series card Port4 Link Event Configuration: Error Frame Event - Error Window |
| 1.3.6.1.4.1.4756.20.731.20.1.332 | Columnf2000EASPort4EFEErrorThresholdRemoteA | read-write | current | f2000EAS Series card Port4 Link Event Configuration: Error Frame Event - Error Threshold |
| 1.3.6.1.4.1.4756.20.731.20.1.333 | Columnf2000EASPort4SPEEErrorWindowRemoteA | read-write | current | f2000EAS Series card Port4 Link Event Configuration: Symbol Period Error Event - Error Window |
| 1.3.6.1.4.1.4756.20.731.20.1.334 | Columnf2000EASPort4SPEEErrorThresholdRemoteA | read-write | current | f2000EAS Series card Port4 Link Event Configuration: Symbol Period Error Event - Error Threshold |
| 1.3.6.1.4.1.4756.20.731.20.1.335 | Columnf2000EASPort4SSEErrorWindowRemoteA | read-write | current | f2000EAS Series card Port4 Link Event Configuration: Seconds Summary Event - Error Window |
| 1.3.6.1.4.1.4756.20.731.20.1.336 | Columnf2000EASPort4SSEErrorThresholdRemoteA | read-write | current | f2000EAS Series card Port4 Link Event Configuration: Seconds Summary Event - Error Threshold |
| 1.3.6.1.4.1.4756.20.731.20.1.337 | Columnf2000EASPort1RxOAMInfoPDURemoteA | read-only | current | f2000EAS Series card Port1 Detailed Link OAM Statistics: Rx OAM Information PDU's |
| 1.3.6.1.4.1.4756.20.731.20.1.338 | Columnf2000EASPort1RxUniqueErrorEventRemoteA | read-only | current | f2000EAS Series card Port1 Detailed Link OAM Statistics: Rx Unique Error Event Notificatio |
| 1.3.6.1.4.1.4756.20.731.20.1.339 | Columnf2000EASPort1RxDuplicateErrorEventRemoteA | read-only | current | f2000EAS Series card Port1 Detailed Link OAM Statistics: Rx Duplicate Error Event Notification |
| 1.3.6.1.4.1.4756.20.731.20.1.340 | Columnf2000EASPort1RxLoopBackControlRemoteA | read-only | current | f2000EAS Series card Port1 Detailed Link OAM Statistics: Rx Loopback Control |
| 1.3.6.1.4.1.4756.20.731.20.1.341 | Columnf2000EASPort1RxVariableRequestRemoteA | read-only | current | f2000EAS Series card Port1 Detailed Link OAM Statistics: Rx Variable Request |
| 1.3.6.1.4.1.4756.20.731.20.1.342 | Columnf2000EASPort1RxVariableResponseRemoteA | read-only | current | f2000EAS Series card Port1 Detailed Link OAM Statistics: Rx Variable Response |
| 1.3.6.1.4.1.4756.20.731.20.1.343 | Columnf2000EASPort1RxOrgSpecificPDURemoteA | read-only | current | f2000EAS Series card Port1 Detailed Link OAM Statistics: Rx Org Specific PDU's |
| 1.3.6.1.4.1.4756.20.731.20.1.344 | Columnf2000EASPort1RxUnsupportedCodesRemoteA | read-only | current | f2000EAS Series card Port1 Detailed Link OAM Statistics: Rx Unsupported Codes |
| 1.3.6.1.4.1.4756.20.731.20.1.345 | Columnf2000EASPort1RxLinkFaultPDURemoteA | read-only | current | f2000EAS Series card Port1 Detailed Link OAM Statistics: Rx Link Fault PDU's |
| 1.3.6.1.4.1.4756.20.731.20.1.346 | Columnf2000EASPort1RxDyingGaspRemoteA | read-only | current | f2000EAS Series card Port1 Detailed Link OAM Statistics: Rx Dying Gasp |
| 1.3.6.1.4.1.4756.20.731.20.1.347 | Columnf2000EASPort1RxCriticalEventPDURemoteA | read-only | current | f2000EAS Series card Port1 Detailed Link OAM Statistics: Rx Dying Gasp |
| 1.3.6.1.4.1.4756.20.731.20.1.348 | Columnf2000EASPort1TxOAMInfoPDURemoteA | read-only | current | f2000EAS Series card Port1 Detailed Link OAM Statistics: Tx OAM Information PDU's |
| 1.3.6.1.4.1.4756.20.731.20.1.349 | Columnf2000EASPort1TxUniqueErrorEventRemoteA | read-only | current | f2000EAS Series card Port1 Detailed Link OAM Statistics: Tx Unique Error Event Notificatio |
| 1.3.6.1.4.1.4756.20.731.20.1.350 | Columnf2000EASPort1TxDuplicateErrorEventRemoteA | read-only | current | f2000EAS Series card Port1 Detailed Link OAM Statistics: Tx Duplicate Error Event Notification |
| 1.3.6.1.4.1.4756.20.731.20.1.351 | Columnf2000EASPort1TxLoopBackControlRemoteA | read-only | current | f2000EAS Series card Port1 Detailed Link OAM Statistics: Tx Loopback Control |
| 1.3.6.1.4.1.4756.20.731.20.1.352 | Columnf2000EASPort1TxVariableRequestRemoteA | read-only | current | f2000EAS Series card Port1 Detailed Link OAM Statistics: Tx Variable Request |
| 1.3.6.1.4.1.4756.20.731.20.1.353 | Columnf2000EASPort1TxVariableResponseRemoteA | read-only | current | f2000EAS Series card Port1 Detailed Link OAM Statistics: Tx Variable Response |
| 1.3.6.1.4.1.4756.20.731.20.1.354 | Columnf2000EASPort1TxOrgSpecificPDURemoteA | read-only | current | f2000EAS Series card Port1 Detailed Link OAM Statistics: Tx Org Specific PDU's |
| 1.3.6.1.4.1.4756.20.731.20.1.355 | Columnf2000EASPort1TxUnsupportedCodesRemoteA | read-only | current | f2000EAS Series card Port1 Detailed Link OAM Statistics: Tx Unsupported Codes |
| 1.3.6.1.4.1.4756.20.731.20.1.356 | Columnf2000EASPort1TxLinkFaultPDURemoteA | read-only | current | f2000EAS Series card Port1 Detailed Link OAM Statistics: Tx Link Fault PDU's |
| 1.3.6.1.4.1.4756.20.731.20.1.357 | Columnf2000EASPort1TxDyingGaspRemoteA | read-only | current | f2000EAS Series card Port1 Detailed Link OAM Statistics: Tx Dying Gasp |
| 1.3.6.1.4.1.4756.20.731.20.1.358 | Columnf2000EASPort1TxCriticalEventPDURemoteA | read-only | current | f2000EAS Series card Port1 Detailed Link OAM Statistics: Tx Dying Gasp |
| 1.3.6.1.4.1.4756.20.731.20.1.359 | Columnf2000EASPort2RxOAMInfoPDURemoteA | read-only | current | f2000EAS Series card Port2 Detailed Link OAM Statistics: Rx OAM Information PDU's |
| 1.3.6.1.4.1.4756.20.731.20.1.360 | Columnf2000EASPort2RxUniqueErrorEventRemoteA | read-only | current | f2000EAS Series card Port2 Detailed Link OAM Statistics: Rx Unique Error Event Notificatio |
| 1.3.6.1.4.1.4756.20.731.20.1.361 | Columnf2000EASPort2RxDuplicateErrorEventRemoteA | read-only | current | f2000EAS Series card Port2 Detailed Link OAM Statistics: Rx Duplicate Error Event Notification |
| 1.3.6.1.4.1.4756.20.731.20.1.362 | Columnf2000EASPort2RxLoopBackControlRemoteA | read-only | current | f2000EAS Series card Port2 Detailed Link OAM Statistics: Rx Loopback Control |
| 1.3.6.1.4.1.4756.20.731.20.1.363 | Columnf2000EASPort2RxVariableRequestRemoteA | read-only | current | f2000EAS Series card Port2 Detailed Link OAM Statistics: Rx Variable Request |
| 1.3.6.1.4.1.4756.20.731.20.1.364 | Columnf2000EASPort2RxVariableResponseRemoteA | read-only | current | f2000EAS Series card Port2 Detailed Link OAM Statistics: Rx Variable Response |
| 1.3.6.1.4.1.4756.20.731.20.1.365 | Columnf2000EASPort2RxOrgSpecificPDURemoteA | read-only | current | f2000EAS Series card Port2 Detailed Link OAM Statistics: Rx Org Specific PDU's |
| 1.3.6.1.4.1.4756.20.731.20.1.366 | Columnf2000EASPort2RxUnsupportedCodesRemoteA | read-only | current | f2000EAS Series card Port2 Detailed Link OAM Statistics: Rx Unsupported Codes |
| 1.3.6.1.4.1.4756.20.731.20.1.367 | Columnf2000EASPort2RxLinkFaultPDURemoteA | read-only | current | f2000EAS Series card Port2 Detailed Link OAM Statistics: Rx Link Fault PDU's |
| 1.3.6.1.4.1.4756.20.731.20.1.368 | Columnf2000EASPort2RxDyingGaspRemoteA | read-only | current | f2000EAS Series card Port2 Detailed Link OAM Statistics: Rx Dying Gasp |
| 1.3.6.1.4.1.4756.20.731.20.1.369 | Columnf2000EASPort2RxCriticalEventPDURemoteA | read-only | current | f2000EAS Series card Port2 Detailed Link OAM Statistics: Rx Dying Gasp |
| 1.3.6.1.4.1.4756.20.731.20.1.370 | Columnf2000EASPort2TxOAMInfoPDURemoteA | read-only | current | f2000EAS Series card Port2 Detailed Link OAM Statistics: Tx OAM Information PDU's |
| 1.3.6.1.4.1.4756.20.731.20.1.371 | Columnf2000EASPort2TxUniqueErrorEventRemoteA | read-only | current | f2000EAS Series card Port2 Detailed Link OAM Statistics: Tx Unique Error Event Notificatio |
| 1.3.6.1.4.1.4756.20.731.20.1.372 | Columnf2000EASPort2TxDuplicateErrorEventRemoteA | read-only | current | f2000EAS Series card Port2 Detailed Link OAM Statistics: Tx Duplicate Error Event Notification |
| 1.3.6.1.4.1.4756.20.731.20.1.373 | Columnf2000EASPort2TxLoopBackControlRemoteA | read-only | current | f2000EAS Series card Port2 Detailed Link OAM Statistics: Tx Loopback Control |
| 1.3.6.1.4.1.4756.20.731.20.1.374 | Columnf2000EASPort2TxVariableRequestRemoteA | read-only | current | f2000EAS Series card Port2 Detailed Link OAM Statistics: Tx Variable Request |
| 1.3.6.1.4.1.4756.20.731.20.1.375 | Columnf2000EASPort2TxVariableResponseRemoteA | read-only | current | f2000EAS Series card Port2 Detailed Link OAM Statistics: Tx Variable Response |
| 1.3.6.1.4.1.4756.20.731.20.1.376 | Columnf2000EASPort2TxOrgSpecificPDURemoteA | read-only | current | f2000EAS Series card Port2 Detailed Link OAM Statistics: Tx Org Specific PDU's |
| 1.3.6.1.4.1.4756.20.731.20.1.377 | Columnf2000EASPort2TxUnsupportedCodesRemoteA | read-only | current | f2000EAS Series card Port2 Detailed Link OAM Statistics: Tx Unsupported Codes |
| 1.3.6.1.4.1.4756.20.731.20.1.378 | Columnf2000EASPort2TxLinkFaultPDURemoteA | read-only | current | f2000EAS Series card Port2 Detailed Link OAM Statistics: Tx Link Fault PDU's |
| 1.3.6.1.4.1.4756.20.731.20.1.379 | Columnf2000EASPort2TxDyingGaspRemoteA | read-only | current | f2000EAS Series card Port2 Detailed Link OAM Statistics: Tx Dying Gasp |
| 1.3.6.1.4.1.4756.20.731.20.1.380 | Columnf2000EASPort2TxCriticalEventPDURemoteA | read-only | current | f2000EAS Series card Port2 Detailed Link OAM Statistics: Tx Dying Gasp |
| 1.3.6.1.4.1.4756.20.731.20.1.381 | Columnf2000EASPort3RxOAMInfoPDURemoteA | read-only | current | f2000EAS Series card Port3 Detailed Link OAM Statistics: Rx OAM Information PDU's |
| 1.3.6.1.4.1.4756.20.731.20.1.382 | Columnf2000EASPort3RxUniqueErrorEventRemoteA | read-only | current | f2000EAS Series card Port3 Detailed Link OAM Statistics: Rx Unique Error Event Notificatio |
| 1.3.6.1.4.1.4756.20.731.20.1.383 | Columnf2000EASPort3RxDuplicateErrorEventRemoteA | read-only | current | f2000EAS Series card Port3 Detailed Link OAM Statistics: Rx Duplicate Error Event Notification |
| 1.3.6.1.4.1.4756.20.731.20.1.384 | Columnf2000EASPort3RxLoopBackControlRemoteA | read-only | current | f2000EAS Series card Port3 Detailed Link OAM Statistics: Rx Loopback Control |
| 1.3.6.1.4.1.4756.20.731.20.1.385 | Columnf2000EASPort3RxVariableRequestRemoteA | read-only | current | f2000EAS Series card Port3 Detailed Link OAM Statistics: Rx Variable Request |
| 1.3.6.1.4.1.4756.20.731.20.1.386 | Columnf2000EASPort3RxVariableResponseRemoteA | read-only | current | f2000EAS Series card Port3 Detailed Link OAM Statistics: Rx Variable Response |
| 1.3.6.1.4.1.4756.20.731.20.1.387 | Columnf2000EASPort3RxOrgSpecificPDURemoteA | read-only | current | f2000EAS Series card Port3 Detailed Link OAM Statistics: Rx Org Specific PDU's |
| 1.3.6.1.4.1.4756.20.731.20.1.388 | Columnf2000EASPort3RxUnsupportedCodesRemoteA | read-only | current | f2000EAS Series card Port3 Detailed Link OAM Statistics: Rx Unsupported Codes |
| 1.3.6.1.4.1.4756.20.731.20.1.389 | Columnf2000EASPort3RxLinkFaultPDURemoteA | read-only | current | f2000EAS Series card Port3 Detailed Link OAM Statistics: Rx Link Fault PDU's |
| 1.3.6.1.4.1.4756.20.731.20.1.390 | Columnf2000EASPort3RxDyingGaspRemoteA | read-only | current | f2000EAS Series card Port3 Detailed Link OAM Statistics: Rx Dying Gasp |
| 1.3.6.1.4.1.4756.20.731.20.1.391 | Columnf2000EASPort3RxCriticalEventPDURemoteA | read-only | current | f2000EAS Series card Port3 Detailed Link OAM Statistics: Rx Dying Gasp |
| 1.3.6.1.4.1.4756.20.731.20.1.392 | Columnf2000EASPort3TxOAMInfoPDURemoteA | read-only | current | f2000EAS Series card Port3 Detailed Link OAM Statistics: Tx OAM Information PDU's |
| 1.3.6.1.4.1.4756.20.731.20.1.393 | Columnf2000EASPort3TxUniqueErrorEventRemoteA | read-only | current | f2000EAS Series card Port3 Detailed Link OAM Statistics: Tx Unique Error Event Notificatio |
| 1.3.6.1.4.1.4756.20.731.20.1.394 | Columnf2000EASPort3TxDuplicateErrorEventRemoteA | read-only | current | f2000EAS Series card Port3 Detailed Link OAM Statistics: Tx Duplicate Error Event Notification |
| 1.3.6.1.4.1.4756.20.731.20.1.395 | Columnf2000EASPort3TxLoopBackControlRemoteA | read-only | current | f2000EAS Series card Port3 Detailed Link OAM Statistics: Tx Loopback Control |
| 1.3.6.1.4.1.4756.20.731.20.1.396 | Columnf2000EASPort3TxVariableRequestRemoteA | read-only | current | f2000EAS Series card Port3 Detailed Link OAM Statistics: Tx Variable Request |
| 1.3.6.1.4.1.4756.20.731.20.1.397 | Columnf2000EASPort3TxVariableResponseRemoteA | read-only | current | f2000EAS Series card Port3 Detailed Link OAM Statistics: Tx Variable Response |
| 1.3.6.1.4.1.4756.20.731.20.1.398 | Columnf2000EASPort3TxOrgSpecificPDURemoteA | read-only | current | f2000EAS Series card Port3 Detailed Link OAM Statistics: Tx Org Specific PDU's |
| 1.3.6.1.4.1.4756.20.731.20.1.399 | Columnf2000EASPort3TxUnsupportedCodesRemoteA | read-only | current | f2000EAS Series card Port3 Detailed Link OAM Statistics: Tx Unsupported Codes |
| 1.3.6.1.4.1.4756.20.731.20.1.400 | Columnf2000EASPort3TxLinkFaultPDURemoteA | read-only | current | f2000EAS Series card Port3 Detailed Link OAM Statistics: Tx Link Fault PDU's |
| 1.3.6.1.4.1.4756.20.731.20.1.401 | Columnf2000EASPort3TxDyingGaspRemoteA | read-only | current | f2000EAS Series card Port3 Detailed Link OAM Statistics: Tx Dying Gasp |
| 1.3.6.1.4.1.4756.20.731.20.1.402 | Columnf2000EASPort3TxCriticalEventPDURemoteA | read-only | current | f2000EAS Series card Port3 Detailed Link OAM Statistics: Tx Dying Gasp |
| 1.3.6.1.4.1.4756.20.731.20.1.403 | Columnf2000EASPort4RxOAMInfoPDURemoteA | read-only | current | f2000EAS Series card Port4 Detailed Link OAM Statistics: Rx OAM Information PDU's |
| 1.3.6.1.4.1.4756.20.731.20.1.404 | Columnf2000EASPort4RxUniqueErrorEventRemoteA | read-only | current | f2000EAS Series card Port4 Detailed Link OAM Statistics: Rx Unique Error Event Notificatio |
| 1.3.6.1.4.1.4756.20.731.20.1.405 | Columnf2000EASPort4RxDuplicateErrorEventRemoteA | read-only | current | f2000EAS Series card Port4 Detailed Link OAM Statistics: Rx Duplicate Error Event Notification |
| 1.3.6.1.4.1.4756.20.731.20.1.406 | Columnf2000EASPort4RxLoopBackControlRemoteA | read-only | current | f2000EAS Series card Port4 Detailed Link OAM Statistics: Rx Loopback Control |
| 1.3.6.1.4.1.4756.20.731.20.1.407 | Columnf2000EASPort4RxVariableRequestRemoteA | read-only | current | f2000EAS Series card Port4 Detailed Link OAM Statistics: Rx Variable Request |
| 1.3.6.1.4.1.4756.20.731.20.1.408 | Columnf2000EASPort4RxVariableResponseRemoteA | read-only | current | f2000EAS Series card Port4 Detailed Link OAM Statistics: Rx Variable Response |
| 1.3.6.1.4.1.4756.20.731.20.1.409 | Columnf2000EASPort4RxOrgSpecificPDURemoteA | read-only | current | f2000EAS Series card Port4 Detailed Link OAM Statistics: Rx Org Specific PDU's |
| 1.3.6.1.4.1.4756.20.731.20.1.410 | Columnf2000EASPort4RxUnsupportedCodesRemoteA | read-only | current | f2000EAS Series card Port4 Detailed Link OAM Statistics: Rx Unsupported Codes |
| 1.3.6.1.4.1.4756.20.731.20.1.411 | Columnf2000EASPort4RxLinkFaultPDURemoteA | read-only | current | f2000EAS Series card Port4 Detailed Link OAM Statistics: Rx Link Fault PDU's |
| 1.3.6.1.4.1.4756.20.731.20.1.412 | Columnf2000EASPort4RxDyingGaspRemoteA | read-only | current | f2000EAS Series card Port4 Detailed Link OAM Statistics: Rx Dying Gasp |
| 1.3.6.1.4.1.4756.20.731.20.1.413 | Columnf2000EASPort4RxCriticalEventPDURemoteA | read-only | current | f2000EAS Series card Port4 Detailed Link OAM Statistics: Rx Dying Gasp |
| 1.3.6.1.4.1.4756.20.731.20.1.414 | Columnf2000EASPort4TxOAMInfoPDURemoteA | read-only | current | f2000EAS Series card Port4 Detailed Link OAM Statistics: Tx OAM Information PDU's |
| 1.3.6.1.4.1.4756.20.731.20.1.415 | Columnf2000EASPort4TxUniqueErrorEventRemoteA | read-only | current | f2000EAS Series card Port4 Detailed Link OAM Statistics: Tx Unique Error Event Notificatio |
| 1.3.6.1.4.1.4756.20.731.20.1.416 | Columnf2000EASPort4TxDuplicateErrorEventRemoteA | read-only | current | f2000EAS Series card Port4 Detailed Link OAM Statistics: Tx Duplicate Error Event Notification |
| 1.3.6.1.4.1.4756.20.731.20.1.417 | Columnf2000EASPort4TxLoopBackControlRemoteA | read-only | current | f2000EAS Series card Port4 Detailed Link OAM Statistics: Tx Loopback Control |
| 1.3.6.1.4.1.4756.20.731.20.1.418 | Columnf2000EASPort4TxVariableRequestRemoteA | read-only | current | f2000EAS Series card Port4 Detailed Link OAM Statistics: Tx Variable Request |
| 1.3.6.1.4.1.4756.20.731.20.1.419 | Columnf2000EASPort4TxVariableResponseRemoteA | read-only | current | f2000EAS Series card Port4 Detailed Link OAM Statistics: Tx Variable Response |
| 1.3.6.1.4.1.4756.20.731.20.1.420 | Columnf2000EASPort4TxOrgSpecificPDURemoteA | read-only | current | f2000EAS Series card Port4 Detailed Link OAM Statistics: Tx Org Specific PDU's |
| 1.3.6.1.4.1.4756.20.731.20.1.421 | Columnf2000EASPort4TxUnsupportedCodesRemoteA | read-only | current | f2000EAS Series card Port4 Detailed Link OAM Statistics: Tx Unsupported Codes |
| 1.3.6.1.4.1.4756.20.731.20.1.422 | Columnf2000EASPort4TxLinkFaultPDURemoteA | read-only | current | f2000EAS Series card Port4 Detailed Link OAM Statistics: Tx Link Fault PDU's |
| 1.3.6.1.4.1.4756.20.731.20.1.423 | Columnf2000EASPort4TxDyingGaspRemoteA | read-only | current | f2000EAS Series card Port4 Detailed Link OAM Statistics: Tx Dying Gasp |
| 1.3.6.1.4.1.4756.20.731.20.1.424 | Columnf2000EASPort4TxCriticalEventPDURemoteA | read-only | current | f2000EAS Series card Port4 Detailed Link OAM Statistics: Tx Dying Gasp |
| 1.3.6.1.4.1.4756.20.731.20.1.425 | Columnf2000EASPort1PDUPermisionRemoteA | read-only | current | f2000EAS Series card Detailed Link OAM Status for Port 1: PDU Permission |
| 1.3.6.1.4.1.4756.20.731.20.1.426 | Columnf2000EASPort1DiscoveryStateRemoteA | read-only | current | f2000EAS Series card Detailed Link OAM Status for Port 1: Discovery State |
| 1.3.6.1.4.1.4756.20.731.20.1.427 | Columnf2000EASPort1PeerMACAddrRemoteA | read-only | current | f2000EAS Series card Detailed Link OAM Status for Port 1: Discovery State |
| 1.3.6.1.4.1.4756.20.731.20.1.428 | Columnf2000EASPort1LocalModeRemoteA | read-only | current | f2000EAS Series card Detailed Link OAM Status for Port 1: RemoteA: Mode |
| 1.3.6.1.4.1.4756.20.731.20.1.429 | Columnf2000EASPort1LocalUnOperationRemoteA | read-only | current | f2000EAS Series card Detailed Link OAM Status for Port 1: RemoteA: Unidirectional Operation Support |
| 1.3.6.1.4.1.4756.20.731.20.1.430 | Columnf2000EASPort1LocalRemoteLbRemoteA | read-only | current | f2000EAS Series card Detailed Link OAM Status for Port 1: RemoteA: Remote Loopback Support |
| 1.3.6.1.4.1.4756.20.731.20.1.431 | Columnf2000EASPort1LocalLMRemoteA | read-only | current | f2000EAS Series card Detailed Link OAM Status for Port 1: RemoteA: Link Monitoring Support |
| 1.3.6.1.4.1.4756.20.731.20.1.432 | Columnf2000EASPort1LocalMIBRetrievalRemoteA | read-only | current | f2000EAS Series card Detailed Link OAM Status for Port 1: RemoteA: MIB Retrieval Support |
| 1.3.6.1.4.1.4756.20.731.20.1.433 | Columnf2000EASPort1LocalMTUSizeRemoteA | read-only | current | f2000EAS Series card Detailed Link OAM Status for Port 1: RemoteA: MTU Size |
| 1.3.6.1.4.1.4756.20.731.20.1.434 | Columnf2000EASPort1LocalMultiStateRemoteA | read-only | current | f2000EAS Series card Detailed Link OAM Status for Port 1: RemoteA: Multiplexer State |
| 1.3.6.1.4.1.4756.20.731.20.1.435 | Columnf2000EASPort1LocalParserStateRemoteA | read-only | current | f2000EAS Series card Detailed Link OAM Status for Port 1: RemoteA: Multiplexer State |
| 1.3.6.1.4.1.4756.20.731.20.1.436 | Columnf2000EASPort1LocalOUIRemoteA | read-only | current | f2000EAS Series card Detailed Link OAM Status for Port 1: RemoteA: Organizational Unique Identification |
| 1.3.6.1.4.1.4756.20.731.20.1.437 | Columnf2000EASPort1LocalPDURevRemoteA | read-only | current | f2000EAS Series card Detailed Link OAM Status for Port 1: RemoteA: PDU Revision |
| 1.3.6.1.4.1.4756.20.731.20.1.438 | Columnf2000EASPort1PeerModeRemoteA | read-only | current | f2000EAS Series card Detailed Link OAM Status for Port 1: Peer: Mode |
| 1.3.6.1.4.1.4756.20.731.20.1.439 | Columnf2000EASPort1PeerUnOperationRemoteA | read-only | current | f2000EAS Series card Detailed Link OAM Status for Port 1: Peer: Unidirectional Operation Support |
| 1.3.6.1.4.1.4756.20.731.20.1.440 | Columnf2000EASPort1PeerRemoteLbRemoteA | read-only | current | f2000EAS Series card Detailed Link OAM Status for Port 1: Peer: Remote Loopback Support |
| 1.3.6.1.4.1.4756.20.731.20.1.441 | Columnf2000EASPort1PeerLMRemoteA | read-only | current | f2000EAS Series card Detailed Link OAM Status for Port 1: Peer: Link Monitoring Support |
| 1.3.6.1.4.1.4756.20.731.20.1.442 | Columnf2000EASPort1PeerMIBRetrievalRemoteA | read-only | current | f2000EAS Series card Detailed Link OAM Status for Port 1: Peer: MIB Retrieval Support |
| 1.3.6.1.4.1.4756.20.731.20.1.443 | Columnf2000EASPort1PeerMTUSizeRemoteA | read-only | current | f2000EAS Series card Detailed Link OAM Status for Port 1: Peer: MTU Size |
| 1.3.6.1.4.1.4756.20.731.20.1.444 | Columnf2000EASPort1PeerMultiStateRemoteA | read-only | current | f2000EAS Series card Detailed Link OAM Status for Port 1: Peer: Multiplexer State |
| 1.3.6.1.4.1.4756.20.731.20.1.445 | Columnf2000EASPort1PeerParserStateRemoteA | read-only | current | f2000EAS Series card Detailed Link OAM Status for Port 1: Peer: Multiplexer State |
| 1.3.6.1.4.1.4756.20.731.20.1.446 | Columnf2000EASPort1PeerOUIRemoteA | read-only | current | f2000EAS Series card Detailed Link OAM Status for Port 1: Peer: Organizational Unique Identification |
| 1.3.6.1.4.1.4756.20.731.20.1.447 | Columnf2000EASPort1PeerPDURevRemoteA | read-only | current | f2000EAS Series card Detailed Link OAM Status for Port 1: Peer: PDU Revision |
| 1.3.6.1.4.1.4756.20.731.20.1.448 | Columnf2000EASPort2PDUPermisionRemoteA | read-only | current | f2000EAS Series card Detailed Link OAM Status for Port 2: PDU Permission |
| 1.3.6.1.4.1.4756.20.731.20.1.449 | Columnf2000EASPort2DiscoveryStateRemoteA | read-only | current | f2000EAS Series card Detailed Link OAM Status for Port 2: Discovery State |
| 1.3.6.1.4.1.4756.20.731.20.1.450 | Columnf2000EASPort2PeerMACAddrRemoteA | read-only | current | f2000EAS Series card Detailed Link OAM Status for Port 2: Discovery State |
| 1.3.6.1.4.1.4756.20.731.20.1.451 | Columnf2000EASPort2LocalModeRemoteA | read-only | current | f2000EAS Series card Detailed Link OAM Status for Port 2: RemoteA: Mode |
| 1.3.6.1.4.1.4756.20.731.20.1.452 | Columnf2000EASPort2LocalUnOperationRemoteA | read-only | current | f2000EAS Series card Detailed Link OAM Status for Port 2: RemoteA: Unidirectional Operation Support |
| 1.3.6.1.4.1.4756.20.731.20.1.453 | Columnf2000EASPort2LocalRemoteLbRemoteA | read-only | current | f2000EAS Series card Detailed Link OAM Status for Port 2: RemoteA: Remote Loopback Support |
| 1.3.6.1.4.1.4756.20.731.20.1.454 | Columnf2000EASPort2LocalLMRemoteA | read-only | current | f2000EAS Series card Detailed Link OAM Status for Port 2: RemoteA: Link Monitoring Support |
| 1.3.6.1.4.1.4756.20.731.20.1.455 | Columnf2000EASPort2LocalMIBRetrievalRemoteA | read-only | current | f2000EAS Series card Detailed Link OAM Status for Port 2: RemoteA: MIB Retrieval Support |
| 1.3.6.1.4.1.4756.20.731.20.1.456 | Columnf2000EASPort2LocalMTUSizeRemoteA | read-only | current | f2000EAS Series card Detailed Link OAM Status for Port 2: RemoteA: MTU Size |
| 1.3.6.1.4.1.4756.20.731.20.1.457 | Columnf2000EASPort2LocalMultiStateRemoteA | read-only | current | f2000EAS Series card Detailed Link OAM Status for Port 2: RemoteA: Multiplexer State |
| 1.3.6.1.4.1.4756.20.731.20.1.458 | Columnf2000EASPort2LocalParserStateRemoteA | read-only | current | f2000EAS Series card Detailed Link OAM Status for Port 2: RemoteA: Multiplexer State |
| 1.3.6.1.4.1.4756.20.731.20.1.459 | Columnf2000EASPort2LocalOUIRemoteA | read-only | current | f2000EAS Series card Detailed Link OAM Status for Port 2: RemoteA: Organizational Unique Identification |
| 1.3.6.1.4.1.4756.20.731.20.1.460 | Columnf2000EASPort2LocalPDURevRemoteA | read-only | current | f2000EAS Series card Detailed Link OAM Status for Port 2: RemoteA: PDU Revision |
| 1.3.6.1.4.1.4756.20.731.20.1.461 | Columnf2000EASPort2PeerModeRemoteA | read-only | current | f2000EAS Series card Detailed Link OAM Status for Port 2: Peer: Mode |
| 1.3.6.1.4.1.4756.20.731.20.1.462 | Columnf2000EASPort2PeerUnOperationRemoteA | read-only | current | f2000EAS Series card Detailed Link OAM Status for Port 2: Peer: Unidirectional Operation Support |
| 1.3.6.1.4.1.4756.20.731.20.1.463 | Columnf2000EASPort2PeerRemoteLbRemoteA | read-only | current | f2000EAS Series card Detailed Link OAM Status for Port 2: Peer: Remote Loopback Support |
| 1.3.6.1.4.1.4756.20.731.20.1.464 | Columnf2000EASPort2PeerLMRemoteA | read-only | current | f2000EAS Series card Detailed Link OAM Status for Port 2: Peer: Link Monitoring Support |
| 1.3.6.1.4.1.4756.20.731.20.1.465 | Columnf2000EASPort2PeerMIBRetrievalRemoteA | read-only | current | f2000EAS Series card Detailed Link OAM Status for Port 2: Peer: MIB Retrieval Support |
| 1.3.6.1.4.1.4756.20.731.20.1.466 | Columnf2000EASPort2PeerMTUSizeRemoteA | read-only | current | f2000EAS Series card Detailed Link OAM Status for Port 2: Peer: MTU Size |
| 1.3.6.1.4.1.4756.20.731.20.1.467 | Columnf2000EASPort2PeerMultiStateRemoteA | read-only | current | f2000EAS Series card Detailed Link OAM Status for Port 2: Peer: Multiplexer State |
| 1.3.6.1.4.1.4756.20.731.20.1.468 | Columnf2000EASPort2PeerParserStateRemoteA | read-only | current | f2000EAS Series card Detailed Link OAM Status for Port 2: Peer: Multiplexer State |
| 1.3.6.1.4.1.4756.20.731.20.1.469 | Columnf2000EASPort2PeerOUIRemoteA | read-only | current | f2000EAS Series card Detailed Link OAM Status for Port 2: Peer: Organizational Unique Identification |
| 1.3.6.1.4.1.4756.20.731.20.1.470 | Columnf2000EASPort2PeerPDURevRemoteA | read-only | current | f2000EAS Series card Detailed Link OAM Status for Port 2: Peer: PDU Revision |
| 1.3.6.1.4.1.4756.20.731.20.1.471 | Columnf2000EASPort3PDUPermisionRemoteA | read-only | current | f2000EAS Series card Detailed Link OAM Status for Port 3: PDU Permission |
| 1.3.6.1.4.1.4756.20.731.20.1.472 | Columnf2000EASPort3DiscoveryStateRemoteA | read-only | current | f2000EAS Series card Detailed Link OAM Status for Port 3: Discovery State |
| 1.3.6.1.4.1.4756.20.731.20.1.473 | Columnf2000EASPort3PeerMACAddrRemoteA | read-only | current | f2000EAS Series card Detailed Link OAM Status for Port 3: Discovery State |
| 1.3.6.1.4.1.4756.20.731.20.1.474 | Columnf2000EASPort3LocalModeRemoteA | read-only | current | f2000EAS Series card Detailed Link OAM Status for Port 3: RemoteA: Mode |
| 1.3.6.1.4.1.4756.20.731.20.1.475 | Columnf2000EASPort3LocalUnOperationRemoteA | read-only | current | f2000EAS Series card Detailed Link OAM Status for Port 3: RemoteA: Unidirectional Operation Support |
| 1.3.6.1.4.1.4756.20.731.20.1.476 | Columnf2000EASPort3LocalRemoteLbRemoteA | read-only | current | f2000EAS Series card Detailed Link OAM Status for Port 3: RemoteA: Remote Loopback Support |
| 1.3.6.1.4.1.4756.20.731.20.1.477 | Columnf2000EASPort3LocalLMRemoteA | read-only | current | f2000EAS Series card Detailed Link OAM Status for Port 3: RemoteA: Link Monitoring Support |
| 1.3.6.1.4.1.4756.20.731.20.1.478 | Columnf2000EASPort3LocalMIBRetrievalRemoteA | read-only | current | f2000EAS Series card Detailed Link OAM Status for Port 3: RemoteA: MIB Retrieval Support |
| 1.3.6.1.4.1.4756.20.731.20.1.479 | Columnf2000EASPort3LocalMTUSizeRemoteA | read-only | current | f2000EAS Series card Detailed Link OAM Status for Port 3: RemoteA: MTU Size |
| 1.3.6.1.4.1.4756.20.731.20.1.480 | Columnf2000EASPort3LocalMultiStateRemoteA | read-only | current | f2000EAS Series card Detailed Link OAM Status for Port 3: RemoteA: Multiplexer State |
| 1.3.6.1.4.1.4756.20.731.20.1.481 | Columnf2000EASPort3LocalParserStateRemoteA | read-only | current | f2000EAS Series card Detailed Link OAM Status for Port 3: RemoteA: Multiplexer State |
| 1.3.6.1.4.1.4756.20.731.20.1.482 | Columnf2000EASPort3LocalOUIRemoteA | read-only | current | f2000EAS Series card Detailed Link OAM Status for Port 3: RemoteA: Organizational Unique Identification |
| 1.3.6.1.4.1.4756.20.731.20.1.483 | Columnf2000EASPort3LocalPDURevRemoteA | read-only | current | f2000EAS Series card Detailed Link OAM Status for Port 3: RemoteA: PDU Revision |
| 1.3.6.1.4.1.4756.20.731.20.1.484 | Columnf2000EASPort3PeerModeRemoteA | read-only | current | f2000EAS Series card Detailed Link OAM Status for Port 3: Peer: Mode |
| 1.3.6.1.4.1.4756.20.731.20.1.485 | Columnf2000EASPort3PeerUnOperationRemoteA | read-only | current | f2000EAS Series card Detailed Link OAM Status for Port 3: Peer: Unidirectional Operation Support |
| 1.3.6.1.4.1.4756.20.731.20.1.486 | Columnf2000EASPort3PeerRemoteLbRemoteA | read-only | current | f2000EAS Series card Detailed Link OAM Status for Port 3: Peer: Remote Loopback Support |
| 1.3.6.1.4.1.4756.20.731.20.1.487 | Columnf2000EASPort3PeerLMRemoteA | read-only | current | f2000EAS Series card Detailed Link OAM Status for Port 3: Peer: Link Monitoring Support |
| 1.3.6.1.4.1.4756.20.731.20.1.488 | Columnf2000EASPort3PeerMIBRetrievalRemoteA | read-only | current | f2000EAS Series card Detailed Link OAM Status for Port 3: Peer: MIB Retrieval Support |
| 1.3.6.1.4.1.4756.20.731.20.1.489 | Columnf2000EASPort3PeerMTUSizeRemoteA | read-only | current | f2000EAS Series card Detailed Link OAM Status for Port 3: Peer: MTU Size |
| 1.3.6.1.4.1.4756.20.731.20.1.490 | Columnf2000EASPort3PeerMultiStateRemoteA | read-only | current | f2000EAS Series card Detailed Link OAM Status for Port 3: Peer: Multiplexer State |
| 1.3.6.1.4.1.4756.20.731.20.1.491 | Columnf2000EASPort3PeerParserStateRemoteA | read-only | current | f2000EAS Series card Detailed Link OAM Status for Port 3: Peer: Multiplexer State |
| 1.3.6.1.4.1.4756.20.731.20.1.492 | Columnf2000EASPort3PeerOUIRemoteA | read-only | current | f2000EAS Series card Detailed Link OAM Status for Port 3: Peer: Organizational Unique Identification |
| 1.3.6.1.4.1.4756.20.731.20.1.493 | Columnf2000EASPort3PeerPDURevRemoteA | read-only | current | f2000EAS Series card Detailed Link OAM Status for Port 3: Peer: PDU Revision |
| 1.3.6.1.4.1.4756.20.731.20.1.494 | Columnf2000EASPort4PDUPermisionRemoteA | read-only | current | f2000EAS Series card Detailed Link OAM Status for Port 4: PDU Permission |
| 1.3.6.1.4.1.4756.20.731.20.1.495 | Columnf2000EASPort4DiscoveryStateRemoteA | read-only | current | f2000EAS Series card Detailed Link OAM Status for Port 4: Discovery State |
| 1.3.6.1.4.1.4756.20.731.20.1.496 | Columnf2000EASPort4PeerMACAddrRemoteA | read-only | current | f2000EAS Series card Detailed Link OAM Status for Port 4: Discovery State |
| 1.3.6.1.4.1.4756.20.731.20.1.497 | Columnf2000EASPort4LocalModeRemoteA | read-only | current | f2000EAS Series card Detailed Link OAM Status for Port 4: RemoteA: Mode |
| 1.3.6.1.4.1.4756.20.731.20.1.498 | Columnf2000EASPort4LocalUnOperationRemoteA | read-only | current | f2000EAS Series card Detailed Link OAM Status for Port 4: RemoteA: Unidirectional Operation Support |
| 1.3.6.1.4.1.4756.20.731.20.1.499 | Columnf2000EASPort4LocalRemoteLbRemoteA | read-only | current | f2000EAS Series card Detailed Link OAM Status for Port 4: RemoteA: Remote Loopback Support |
| 1.3.6.1.4.1.4756.20.731.20.1.500 | Columnf2000EASPort4LocalLMRemoteA | read-only | current | f2000EAS Series card Detailed Link OAM Status for Port 4: RemoteA: Link Monitoring Support |
| 1.3.6.1.4.1.4756.20.731.20.1.501 | Columnf2000EASPort4LocalMIBRetrievalRemoteA | read-only | current | f2000EAS Series card Detailed Link OAM Status for Port 4: RemoteA: MIB Retrieval Support |
| 1.3.6.1.4.1.4756.20.731.20.1.502 | Columnf2000EASPort4LocalMTUSizeRemoteA | read-only | current | f2000EAS Series card Detailed Link OAM Status for Port 4: RemoteA: MTU Size |
| 1.3.6.1.4.1.4756.20.731.20.1.503 | Columnf2000EASPort4LocalMultiStateRemoteA | read-only | current | f2000EAS Series card Detailed Link OAM Status for Port 4: RemoteA: Multiplexer State |
| 1.3.6.1.4.1.4756.20.731.20.1.504 | Columnf2000EASPort4LocalParserStateRemoteA | read-only | current | f2000EAS Series card Detailed Link OAM Status for Port 4: RemoteA: Multiplexer State |
| 1.3.6.1.4.1.4756.20.731.20.1.505 | Columnf2000EASPort4LocalOUIRemoteA | read-only | current | f2000EAS Series card Detailed Link OAM Status for Port 4: RemoteA: Organizational Unique Identification |
| 1.3.6.1.4.1.4756.20.731.20.1.506 | Columnf2000EASPort4LocalPDURevRemoteA | read-only | current | f2000EAS Series card Detailed Link OAM Status for Port 4: RemoteA: PDU Revision |
| 1.3.6.1.4.1.4756.20.731.20.1.507 | Columnf2000EASPort4PeerModeRemoteA | read-only | current | f2000EAS Series card Detailed Link OAM Status for Port 4: Peer: Mode |
| 1.3.6.1.4.1.4756.20.731.20.1.508 | Columnf2000EASPort4PeerUnOperationRemoteA | read-only | current | f2000EAS Series card Detailed Link OAM Status for Port 4: Peer: Unidirectional Operation Support |
| 1.3.6.1.4.1.4756.20.731.20.1.509 | Columnf2000EASPort4PeerRemoteLbRemoteA | read-only | current | f2000EAS Series card Detailed Link OAM Status for Port 4: Peer: Remote Loopback Support |
| 1.3.6.1.4.1.4756.20.731.20.1.510 | Columnf2000EASPort4PeerLMRemoteA | read-only | current | f2000EAS Series card Detailed Link OAM Status for Port 4: Peer: Link Monitoring Support |
| 1.3.6.1.4.1.4756.20.731.20.1.511 | Columnf2000EASPort4PeerMIBRetrievalRemoteA | read-only | current | f2000EAS Series card Detailed Link OAM Status for Port 4: Peer: MIB Retrieval Support |
| 1.3.6.1.4.1.4756.20.731.20.1.512 | Columnf2000EASPort4PeerMTUSizeRemoteA | read-only | current | EDD Series card Detailed Link OAM Status for Port 4: Peer: MTU Size |
| 1.3.6.1.4.1.4756.20.731.20.1.513 | Columnf2000EASPort4PeerMultiStateRemoteA | read-only | current | f2000EAS Series card Detailed Link OAM Status for Port 4: Peer: Multiplexer State |
| 1.3.6.1.4.1.4756.20.731.20.1.514 | Columnf2000EASPort4PeerParserStateRemoteA | read-only | current | f2000EAS Series card Detailed Link OAM Status for Port 4: Peer: Multiplexer State |
| 1.3.6.1.4.1.4756.20.731.20.1.515 | Columnf2000EASPort4PeerOUIRemoteA | read-only | current | f2000EAS Series card Detailed Link OAM Status for Port 4: Peer: Organizational Unique Identification |
| 1.3.6.1.4.1.4756.20.731.20.1.516 | Columnf2000EASPort4PeerPDURevRemoteA | read-only | current | f2000EAS Series card Detailed Link OAM Status for Port 4: Peer: PDU Revision |
| 1.3.6.1.4.1.4756.20.731.20.1.517 | Columnf2000EASCLEAROAMCOUNTERRemoteA | read-write | current | f2000EAS Series card Clear OAM Counter: 0: Off 1: Action |
| 1.3.6.1.4.1.4756.20.731.20.1.518 | Columnf2000EASLoopProtectionEnableRemoteA | read-write | current | f2000EAS Series card Loop Protection Configuration: General Settings - Enable Loop Protection 0: Disable 1: Enable |
| 1.3.6.1.4.1.4756.20.731.20.1.519 | Columnf2000EASLoopProtectionTxTimeRemoteA | read-write | current | f2000EAS Series card Loop Protection Configuration: General Settings - Transmission Time |
| 1.3.6.1.4.1.4756.20.731.20.1.520 | Columnf2000EASLoopProtectionShutdownTimeRemoteA | read-write | current | f2000EAS Series card Loop Protection Configuration: General Settings - Shutdown Time |
| 1.3.6.1.4.1.4756.20.731.20.1.521 | Columnf2000EASLoopProtectionPort1EnabledRemoteA | read-write | current | f2000EAS Series card Loop Protection Configuration for Port 1: Port Configuration - Enable 0: Disable 1: Enable |
| 1.3.6.1.4.1.4756.20.731.20.1.522 | Columnf2000EASLoopProtectionPort1ActionRemoteA | read-write | current | f2000EAS Series card Loop Protection Configuration for Port 1: Port Configuration - Action 0: Shutdown Port 1: Shutdown Port And Log 2: Log Only |
| 1.3.6.1.4.1.4756.20.731.20.1.523 | Columnf2000EASLoopProtectionPort1TxModeRemoteA | read-write | current | f2000EAS Series card Loop Protection Configuration for Port 1: Port Configuration - Tx Mode 0: Disable 1: Enable |
| 1.3.6.1.4.1.4756.20.731.20.1.524 | Columnf2000EASLoopProtectionPort2EnabledRemoteA | read-write | current | f2000EAS Series card Loop Protection Configuration for Port 2: Port Configuration - Enable 0: Disable 1: Enable |
| 1.3.6.1.4.1.4756.20.731.20.1.525 | Columnf2000EASLoopProtectionPort2ActionRemoteA | read-write | current | f2000EAS Series card Loop Protection Configuration for Port 2: Port Configuration - Action 0: Shutdown Port 1: Shutdown Port And Log 2: Log Only |
| 1.3.6.1.4.1.4756.20.731.20.1.526 | Columnf2000EASLoopProtectionPort2TxModeRemoteA | read-write | current | f2000EAS Series card Loop Protection Configuration for Port 2: Port Configuration - Tx Mode 0: Disable 1: Enable |
| 1.3.6.1.4.1.4756.20.731.20.1.527 | Columnf2000EASLoopProtectionPort3EnabledRemoteA | read-write | current | f2000EASE Series card Loop Protection Configuration for Port 3: Port Configuration - Enable 0: Disable 1: Enable |
| 1.3.6.1.4.1.4756.20.731.20.1.528 | Columnf2000EASLoopProtectionPort3ActionRemoteA | read-write | current | f2000EAS Series card Loop Protection Configuration for Port 3: Port Configuration - Action 0: Shutdown Port 1: Shutdown Port And Log 2: Log Only |
| 1.3.6.1.4.1.4756.20.731.20.1.529 | Columnf2000EASLoopProtectionPort3TxModeRemoteA | read-write | current | f2000EAS Series card Loop Protection Configuration for Port 3: Port Configuration - Tx Mode 0: Disable 1: Enable |
| 1.3.6.1.4.1.4756.20.731.20.1.530 | Columnf2000EASLoopProtectionPort4EnabledRemoteA | read-write | current | f2000EAS Series card Loop Protection Configuration for Port 4: Port Configuration - Enable 0: Disable 1: Enable |
| 1.3.6.1.4.1.4756.20.731.20.1.531 | Columnf2000EASLoopProtectionPort4ActionRemoteA | read-write | current | f2000EAS Series card Loop Protection Configuration for Port 4: Port Configuration - Action 0: Shutdown Port 1: Shutdown Port And Log 2: Log Only |
| 1.3.6.1.4.1.4756.20.731.20.1.532 | Columnf2000EASLoopProtectionPort4TxModeRemoteA | read-write | current | f2000EAS Series card Loop Protection Configuration for Port 41: Port Configuration - Tx Mode 0: Disable 1: Enable |
| 1.3.6.1.4.1.4756.20.731.20.1.533 | Columnf2000EASLoopProtectionPort1ActionStsRemoteA | read-only | current | f2000EAS Series card Loop Protection Status for Port 1: Action |
| 1.3.6.1.4.1.4756.20.731.20.1.534 | Columnf2000EASLoopProtectionPort1TransStsRemoteA | read-only | current | f2000EAS Series card Loop Protection Status for Port 1: Transmit |
| 1.3.6.1.4.1.4756.20.731.20.1.535 | Columnf2000EASLoopProtectionPort1LoopsStsRemoteA | read-only | current | f2000EAS Series card Loop Protection Status for Port 1: Loops |
| 1.3.6.1.4.1.4756.20.731.20.1.536 | Columnf2000EASLoopProtectionPort1StatusRemoteA | read-only | current | f2000EAS Series card Loop Protection Status for Port 1: Status |
| 1.3.6.1.4.1.4756.20.731.20.1.537 | Columnf2000EASLoopProtectionPort1LoopStsRemoteA | read-only | current | f2000EAS Series card Loop Protection Status for Port 1: Loop |
| 1.3.6.1.4.1.4756.20.731.20.1.538 | Columnf2000EASLoopProtectionPort2ActionStsRemoteA | read-only | current | f2000EAS Series card Loop Protection Status for Port 2: Action |
| 1.3.6.1.4.1.4756.20.731.20.1.539 | Columnf2000EASLoopProtectionPort2TransStsRemoteA | read-only | current | f2000EAS Series card Loop Protection Status for Port 2: Transmit |
| 1.3.6.1.4.1.4756.20.731.20.1.540 | Columnf2000EASLoopProtectionPort2LoopsStsRemoteA | read-only | current | f2000EAS Series card Loop Protection Status for Port 2: Loops |
| 1.3.6.1.4.1.4756.20.731.20.1.541 | Columnf2000EASLoopProtectionPort2StatusRemoteA | read-only | current | f2000EAS Series card Loop Protection Status for Port 2: Status |
| 1.3.6.1.4.1.4756.20.731.20.1.542 | Columnf2000EASLoopProtectionPort2LoopStsRemoteA | read-only | current | f2000EAS Series card Loop Protection Status for Port 2: Loop |
| 1.3.6.1.4.1.4756.20.731.20.1.543 | Columnf2000EASLoopProtectionPort3ActionStsRemoteA | read-only | current | f2000EAS Series card Loop Protection Status for Port 3: Action |
| 1.3.6.1.4.1.4756.20.731.20.1.544 | Columnf2000EASLoopProtectionPort3TransStsRemoteA | read-only | current | f2000EAS Series card Loop Protection Status for Port 3: Transmit |
| 1.3.6.1.4.1.4756.20.731.20.1.545 | Columnf2000EASLoopProtectionPort3LoopsStsRemoteA | read-only | current | f2000EAS Series card Loop Protection Status for Port 3: Loops |
| 1.3.6.1.4.1.4756.20.731.20.1.546 | Columnf2000EASLoopProtectionPort3StatusRemoteA | read-only | current | f2000EAS Series card Loop Protection Status for Port 3: Status |
| 1.3.6.1.4.1.4756.20.731.20.1.547 | Columnf2000EASLoopProtectionPort3LoopStsRemoteA | read-only | current | f2000EAS Series card Loop Protection Status for Port 3: Loop |
| 1.3.6.1.4.1.4756.20.731.20.1.548 | Columnf2000EASLoopProtectionPort4ActionStsRemoteA | read-only | current | f2000EAS Series card Loop Protection Status for Port 4: Action |
| 1.3.6.1.4.1.4756.20.731.20.1.549 | Columnf2000EASLoopProtectionPort4TransStsRemoteA | read-only | current | f2000EAS Series card Loop Protection Status for Port 4: Transmit |
| 1.3.6.1.4.1.4756.20.731.20.1.550 | Columnf2000EASLoopProtectionPort4LoopsStsRemoteA | read-only | current | f2000EAS Series card Loop Protection Status for Port 4: Loops |
| 1.3.6.1.4.1.4756.20.731.20.1.551 | Columnf2000EASLoopProtectionPort4StatusRemoteA | read-only | current | f2000EAS Series card Loop Protection Status for Port 4: Status |
| 1.3.6.1.4.1.4756.20.731.20.1.552 | Columnf2000EASLoopProtectionPort4LoopStsRemoteA | read-only | current | f2000EAS Series card Loop Protection Status for Port 4: Loop |
| 1.3.6.1.4.1.4756.20.731.20.1.553 | Columnf2000EASSTPProtocolVersionRemoteA | read-write | current | f2000EAS Series card STP Bridge Configuration: Basic Settings - Protocol Version 0: STP 1: RSTP 2: MSTP |
| 1.3.6.1.4.1.4756.20.731.20.1.554 | Columnf2000EASSTPBridgePriorityRemoteA | read-write | current | f2000EAS Series card STP Bridge Configuration: Basic Settings - Bridge Priority 0: 0 1: 4096 2: 8192 3: 12288 4: 16384 5: 20480 6: 24576 7: 28672 8: 32768 9: 3… |
| 1.3.6.1.4.1.4756.20.731.20.1.555 | Columnf2000EASSTPForwardDelayRemoteA | read-write | current | f2000EAS Series card STP Bridge Configuration: Basic Settings - Forward Delay |
| 1.3.6.1.4.1.4756.20.731.20.1.556 | Columnf2000EASSTPMaxAgeRemoteA | read-write | current | f2000EAS Series card STP Bridge Configuration: Basic Settings - Max Age |
| 1.3.6.1.4.1.4756.20.731.20.1.557 | Columnf2000EASSTPMaximumHopCountRemoteA | read-write | current | f2000EAS Series card STP Bridge Configuration: Basic Settings - Maximum Hop Count |
| 1.3.6.1.4.1.4756.20.731.20.1.558 | Columnf2000EASSTPTransmitHoldCountRemoteA | read-write | current | f2000EAS Series card STP Bridge Configuration: Basic Settings - Transmit Hold Count |
| 1.3.6.1.4.1.4756.20.731.20.1.559 | Columnf2000EASSTPEdgePortBPDUFilteringRemoteA | read-write | current | f2000EAS Series card STP Bridge Configuration: Advanced Settings - Edge Port BPDU Filtering 0: Off 1: On |
| 1.3.6.1.4.1.4756.20.731.20.1.560 | Columnf2000EASSTPEdgePortBPDUGuardRemoteA | read-write | current | f2000EAS Series card STP Bridge Configuration: Advanced Settings - Edge Port BPDU Guard 0: Off 1: On |
| 1.3.6.1.4.1.4756.20.731.20.1.561 | Columnf2000EASSTPPortErrorRecoveryTimeoutRemoteA | read-write | current | f2000EAS Series card STP Bridge Configuration: Advanced Settings - Port Error Recovery Timeout 0: Off 1: On |
| 1.3.6.1.4.1.4756.20.731.20.1.562 | Columnf2000EASMSTIConfigurationNameRemoteA | read-write | current | f2000EAS Series card MSTI Configuration: Configuration Identification - Configuration Name |
| 1.3.6.1.4.1.4756.20.731.20.1.563 | Columnf2000EASMSTIConfigurationRevisionRemoteA | read-write | current | f2000EAS Series card MSTI Configuration: Configuration Identification - Configuration Revision |
| 1.3.6.1.4.1.4756.20.731.20.1.564 | Columnf2000EASMSTI1VLANsMappingRemoteA | read-write | current | f2000EAS Series card MSTI Configuration: MSTI Mapping - MSTI 1 |
| 1.3.6.1.4.1.4756.20.731.20.1.565 | Columnf2000EASMSTI2VLANsMappingRemoteA | read-write | current | f2000EAS Series card MSTI Configuration: MSTI Mapping - MSTI 2 |
| 1.3.6.1.4.1.4756.20.731.20.1.566 | Columnf2000EASMSTI3VLANsMappingRemoteA | read-write | current | f2000EAS Series card MSTI Configuration: MSTI Mapping - MSTI 3 |
| 1.3.6.1.4.1.4756.20.731.20.1.567 | Columnf2000EASMSTI4VLANsMappingRemoteA | read-write | current | f2000EAS Series card MSTI Configuration: MSTI Mapping - MSTI 4 |
| 1.3.6.1.4.1.4756.20.731.20.1.568 | Columnf2000EASMSTI5VLANsMappingRemoteA | read-write | current | f2000EAS Series card MSTI Configuration: MSTI Mapping - MSTI 5 |
| 1.3.6.1.4.1.4756.20.731.20.1.569 | Columnf2000EASMSTI6VLANsMappingRemoteA | read-write | current | f2000EAS Series card MSTI Configuration: MSTI Mapping - MSTI 6 |
| 1.3.6.1.4.1.4756.20.731.20.1.570 | Columnf2000EASMSTI7VLANsMappingRemoteA | read-write | current | f2000EAS Series card MSTI Configuration: MSTI Mapping - MSTI 7 |
| 1.3.6.1.4.1.4756.20.731.20.1.571 | Columnf2000EASCISTAggregatedSTPEnabledRemoteA | read-write | current | f2000EAS Series card STP CIST Port Configuration: CIST Aggregated Port Configuration - STP Enabled |
| 1.3.6.1.4.1.4756.20.731.20.1.572 | Columnf2000EASCISTAggregatedPathCostRemoteA | read-write | current | f2000EAS Series card STP CIST Port Configuration: CIST Aggregated Port Configuration - Path Cost Valid values are in the range 0 to 200000000. Setting 0 means … |
| 1.3.6.1.4.1.4756.20.731.20.1.573 | Columnf2000EASCISTAggregatedPriorityRemoteA | read-write | current | f2000EAS Series card STP CIST Port Configuration: CIST Aggregated Port Configuration - Priority |
| 1.3.6.1.4.1.4756.20.731.20.1.574 | Columnf2000EASCISTAggregatedAdminEdgeRemoteA | read-write | current | f2000EAS Series card STP CIST Port Configuration: CIST Aggregated Port Configuration - STP Enabled 0: Non-edge 1: Edge |
| 1.3.6.1.4.1.4756.20.731.20.1.575 | Columnf2000EASCISTAggregatedAutoEdgeRemoteA | read-write | current | f2000EAS Series card STP CIST Port Configuration: CIST Aggregated Port Configuration - Auto Edge 0: Non-edge 1: Edge |
| 1.3.6.1.4.1.4756.20.731.20.1.576 | Columnf2000EASCISTAggregatedRestrictedRoleRemoteA | read-write | current | f2000EAS Series card STP CIST Port Configuration: CIST Aggregated Port Configuration - Restricted Role 0: Non-edge 1: Edge |
| 1.3.6.1.4.1.4756.20.731.20.1.577 | Columnf2000EASCISTAggregatedRestrictedTCNRemoteA | read-write | current | f2000EAS Series card STP CIST Port Configuration: CIST Aggregated Port Configuration - Restricted TCN 0: Non-edge 1: Edge |
| 1.3.6.1.4.1.4756.20.731.20.1.578 | Columnf2000EASCISTAggregatedBPDUGuardRemoteA | read-write | current | f2000EAS Series card STP CIST Port Configuration: CIST Aggregated Port Configuration - BPDU Guard 0: Non-edge 1: Edge |
| 1.3.6.1.4.1.4756.20.731.20.1.579 | Columnf2000EASCISTAggregatedPointToPointRemoteA | read-write | current | f2000EAS Series card STP CIST Port Configuration: CIST Aggregated Port Configuration - Point-to-point 0: Forced True 1: Forced False 2: Auto |
| 1.3.6.1.4.1.4756.20.731.20.1.580 | Columnf2000EASCISTPort1STPEnabledRemoteA | read-write | current | f2000EAS Series card STP CIST Port Configuration: CIST Normal Port1 Configuration - STP Enabled |
| 1.3.6.1.4.1.4756.20.731.20.1.581 | Columnf2000EASCISTPort1PathCostRemoteA | read-write | current | f2000EAS Series card STP CIST Port Configuration: CIST Normal Port1 Configuration - Path Cost Valid values are in the range 0 to 200000000. Setting 0 means Aut… |
| 1.3.6.1.4.1.4756.20.731.20.1.582 | Columnf2000EASCISTPort1PriorityRemoteA | read-write | current | f2000EAS Series card STP CIST Port Configuration: CIST Normal Port1 Configuration - Priority |
| 1.3.6.1.4.1.4756.20.731.20.1.583 | Columnf2000EASCISTPort1AdminEdgeRemoteA | read-write | current | f2000EAS Series card STP CIST Port Configuration: CIST Normal Port1 Configuration - STP Enabled 0: Non-edge 1: Edge |
| 1.3.6.1.4.1.4756.20.731.20.1.584 | Columnf2000EASCISTPort1AutoEdgeRemoteA | read-write | current | f2000EAS Series card STP CIST Port Configuration: CIST Normal Port1 Configuration - Auto Edge 0: Non-edge 1: Edge |
| 1.3.6.1.4.1.4756.20.731.20.1.585 | Columnf2000EASCISTPort1RestrictedRoleRemoteA | read-write | current | f2000EAS Series card STP CIST Port Configuration: CIST Normal Port1 Configuration - Restricted Role 0: Non-edge 1: Edge |
| 1.3.6.1.4.1.4756.20.731.20.1.586 | Columnf2000EASCISTPort1RestrictedTCNRemoteA | read-write | current | f2000EAS Series card STP CIST Port Configuration: CIST Normal Port1 Configuration - Restricted TCN 0: Non-edge 1: Edge |
| 1.3.6.1.4.1.4756.20.731.20.1.587 | Columnf2000EASCISTPort1BPDUGuardRemoteA | read-write | current | f2000EAS Series card STP CIST Port Configuration: CIST Normal Port1 Configuration - BPDU Guard 0: Non-edge 1: Edge |
| 1.3.6.1.4.1.4756.20.731.20.1.588 | Columnf2000EASCISTPort1PointToPointRemoteA | read-write | current | f2000EAS Series card STP CIST Port Configuration: CIST Normal Port1 Configuration - Point-to-point 0: Forced True 1: Forced False 2: Auto |
| 1.3.6.1.4.1.4756.20.731.20.1.589 | Columnf2000EASCISTPort2STPEnabledRemoteA | read-write | current | f2000EAS Series card STP CIST Port Configuration: CIST Normal Port2 Configuration - STP Enabled |
| 1.3.6.1.4.1.4756.20.731.20.1.590 | Columnf2000EASCISTPort2PathCostRemoteA | read-write | current | f2000EAS Series card STP CIST Port Configuration: CIST Normal Port2 Configuration - Path Cost Valid values are in the range 0 to 200000000. Setting 0 means Aut… |
| 1.3.6.1.4.1.4756.20.731.20.1.591 | Columnf2000EASCISTPort2PriorityRemoteA | read-write | current | f2000EAS Series card STP CIST Port Configuration: CIST Normal Port2 Configuration - Priority |
| 1.3.6.1.4.1.4756.20.731.20.1.592 | Columnf2000EASCISTPort2AdminEdgeRemoteA | read-write | current | f2000EAS Series card STP CIST Port Configuration: CIST Normal Port2 Configuration - STP Enabled 0: Non-edge 1: Edge |
| 1.3.6.1.4.1.4756.20.731.20.1.593 | Columnf2000EASCISTPort2AutoEdgeRemoteA | read-write | current | f2000EAS Series card STP CIST Port Configuration: CIST Normal Port2 Configuration - Auto Edge 0: Non-edge 1: Edge |
| 1.3.6.1.4.1.4756.20.731.20.1.594 | Columnf2000EASCISTPort2RestrictedRoleRemoteA | read-write | current | f2000EAS Series card STP CIST Port Configuration: CIST Normal Port2 Configuration - Restricted Role 0: Non-edge 1: Edge |
| 1.3.6.1.4.1.4756.20.731.20.1.595 | Columnf2000EASCISTPort2RestrictedTCNRemoteA | read-write | current | f2000EAS Series card STP CIST Port Configuration: CIST Normal Port2 Configuration - Restricted TCN 0: Non-edge 1: Edge |
| 1.3.6.1.4.1.4756.20.731.20.1.596 | Columnf2000EASCISTPort2BPDUGuardRemoteA | read-write | current | f2000EAS Series card STP CIST Port Configuration: CIST Normal Port2 Configuration - BPDU Guard 0: Non-edge 1: Edge |
| 1.3.6.1.4.1.4756.20.731.20.1.597 | Columnf2000EASCISTPort2PointToPointRemoteA | read-write | current | f2000EAS Series card STP CIST Port Configuration: CIST Normal Port2 Configuration - Point-to-point 0: Forced True 1: Forced False 2: Auto |
| 1.3.6.1.4.1.4756.20.731.20.1.598 | Columnf2000EASCISTPort3STPEnabledRemoteA | read-write | current | f2000EAS Series card STP CIST Port Configuration: CIST Normal Port3 Configuration - STP Enabled |
| 1.3.6.1.4.1.4756.20.731.20.1.599 | Columnf2000EASCISTPort3PathCostRemoteA | read-write | current | f2000EAS Series card STP CIST Port Configuration: CIST Normal Port3 Configuration - Path Cost Valid values are in the range 0 to 200000000. Setting 0 means Aut… |
| 1.3.6.1.4.1.4756.20.731.20.1.600 | Columnf2000EASCISTPort3PriorityRemoteA | read-write | current | f2000EAS Series card STP CIST Port Configuration: CIST Normal Port3 Configuration - Priority |
| 1.3.6.1.4.1.4756.20.731.20.1.601 | Columnf2000EASCISTPort3AdminEdgeRemoteA | read-write | current | f2000EAS Series card STP CIST Port Configuration: CIST Normal Port3 Configuration - STP Enabled 0: Non-edge 1: Edge |
| 1.3.6.1.4.1.4756.20.731.20.1.602 | Columnf2000EASCISTPort3AutoEdgeRemoteA | read-write | current | f2000EAS Series card STP CIST Port Configuration: CIST Normal Port3 Configuration - Auto Edge 0: Non-edge 1: Edge |
| 1.3.6.1.4.1.4756.20.731.20.1.603 | Columnf2000EASCISTPort3RestrictedRoleRemoteA | read-write | current | f2000EAS Series card STP CIST Port Configuration: CIST Normal Port3 Configuration - Restricted Role 0: Non-edge 1: Edge |
| 1.3.6.1.4.1.4756.20.731.20.1.604 | Columnf2000EASCISTPort3RestrictedTCNRemoteA | read-write | current | f2000EAS Series card STP CIST Port Configuration: CIST Normal Port3 Configuration - Restricted TCN 0: Non-edge 1: Edge |
| 1.3.6.1.4.1.4756.20.731.20.1.605 | Columnf2000EASCISTPort3BPDUGuardRemoteA | read-write | current | f2000EAS Series card STP CIST Port Configuration: CIST Normal Port3 Configuration - BPDU Guard 0: Non-edge 1: Edge |
| 1.3.6.1.4.1.4756.20.731.20.1.606 | Columnf2000EASCISTPort3PointToPointRemoteA | read-write | current | f2000EAS Series card STP CIST Port Configuration: CIST Normal Port3 Configuration - Point-to-point 0: Forced True 1: Forced False 2: Auto |
| 1.3.6.1.4.1.4756.20.731.20.1.607 | Columnf2000EASCISTPort4STPEnabledRemoteA | read-write | current | f2000EAS Series card STP CIST Port Configuration: CIST Normal Port4 Configuration - STP Enabled |
| 1.3.6.1.4.1.4756.20.731.20.1.608 | Columnf2000EASCISTPort4PathCostRemoteA | read-write | current | f2000EAS Series card STP CIST Port Configuration: CIST Normal Port4 Configuration - Path Cost Valid values are in the range 0 to 200000000. Setting 0 means Aut… |
| 1.3.6.1.4.1.4756.20.731.20.1.609 | Columnf2000EASCISTPort4PriorityRemoteA | read-write | current | f2000EAS Series card STP CIST Port Configuration: CIST Normal Port4 Configuration - Priority |
| 1.3.6.1.4.1.4756.20.731.20.1.610 | Columnf2000EASCISTPort4AdminEdgeRemoteA | read-write | current | f2000EAS Series card STP CIST Port Configuration: CIST Normal Port4 Configuration - STP Enabled 0: Non-edge 1: Edge |
| 1.3.6.1.4.1.4756.20.731.20.1.611 | Columnf2000EASCISTPort4AutoEdgeRemoteA | read-write | current | f2000EAS Series card STP CIST Port Configuration: CIST Normal Port4 Configuration - Auto Edge 0: Non-edge 1: Edge |
| 1.3.6.1.4.1.4756.20.731.20.1.612 | Columnf2000EASCISTPort4RestrictedRoleRemoteA | read-write | current | f2000EAS Series card STP CIST Port Configuration: CIST Normal Port4 Configuration - Restricted Role 0: Non-edge 1: Edge |
| 1.3.6.1.4.1.4756.20.731.20.1.613 | Columnf2000EASCISTPort4RestrictedTCNRemoteA | read-write | current | f2000EAS Series card STP CIST Port Configuration: CIST Normal Port4 Configuration - Restricted TCN 0: Non-edge 1: Edge |
| 1.3.6.1.4.1.4756.20.731.20.1.614 | Columnf2000EASCISTPort4BPDUGuardRemoteA | read-write | current | f2000EAS Series card STP CIST Port Configuration: CIST Normal Port4 Configuration - BPDU Guard 0: Non-edge 1: Edge |
| 1.3.6.1.4.1.4756.20.731.20.1.615 | Columnf2000EASCISTPort4PointToPointRemoteA | read-write | current | f2000EAS Series card STP CIST Port Configuration: CIST Normal Port4 Configuration - Point-to-point 0: Forced True 1: Forced False 2: Auto |
| 1.3.6.1.4.1.4756.20.731.20.1.616 | Columnf2000EASMSTI1AggregatedPathCostRemoteA | read-write | current | f2000EAS Series card MSTI Port Configuration: MSTI1 Aggregated Ports Configuration - Path Cost Valid values are in the range 0 to 200000000. Setting 0 means Au… |
| 1.3.6.1.4.1.4756.20.731.20.1.617 | Columnf2000EASMSTI1AggregatedPriorityRemoteA | read-write | current | f2000EAS Series card MSTI Port Configuration: MSTI1 Aggregated Ports Configuration - Priority |
| 1.3.6.1.4.1.4756.20.731.20.1.618 | Columnf2000EASMSTI1Port1PathCostRemoteA | read-write | current | f2000EAS Series card MSTI Port Configuration: MSTI1 Normal Port1 Configuration - Path Cost Valid values are in the range 0 to 200000000. Setting 0 means Auto p… |
| 1.3.6.1.4.1.4756.20.731.20.1.619 | Columnf2000EASMSTI1Port1PriorityRemoteA | read-write | current | f2000EAS Series card MSTI Port Configuration: MSTI1 Normal Port1 Configuration - Priority |
| 1.3.6.1.4.1.4756.20.731.20.1.620 | Columnf2000EASMSTI1Port2PathCostRemoteA | read-write | current | f2000EAS Series card MSTI Port Configuration: MSTI1 Normal Port2 Configuration - Path Cost Valid values are in the range 0 to 200000000. Setting 0 means Auto p… |
| 1.3.6.1.4.1.4756.20.731.20.1.621 | Columnf2000EASMSTI1Port2PriorityRemoteA | read-write | current | f2000EAS Series card MSTI Port Configuration: MSTI1 Normal Port2 Configuration - Priority |
| 1.3.6.1.4.1.4756.20.731.20.1.622 | Columnf2000EASMSTI1Port3PathCostRemoteA | read-write | current | f2000EAS Series card MSTI Port Configuration: MSTI1 Normal Port3 Configuration - Path Cost Valid values are in the range 0 to 200000000. Setting 0 means Auto p… |
| 1.3.6.1.4.1.4756.20.731.20.1.623 | Columnf2000EASMSTI1Port3PriorityRemoteA | read-write | current | f2000EAS Series card MSTI Port Configuration: MSTI1 Normal Port3 Configuration - Priority |
| 1.3.6.1.4.1.4756.20.731.20.1.624 | Columnf2000EASMSTI1Port4PathCostRemoteA | read-write | current | f2000EAS Series card MSTI Port Configuration: MSTI1 Normal Port4 Configuration - Path Cost Valid values are in the range 0 to 200000000. Setting 0 means Auto p… |
| 1.3.6.1.4.1.4756.20.731.20.1.625 | Columnf2000EASMSTI1Port4PriorityRemoteA | read-write | current | f2000EAS Series card MSTI Port Configuration: MSTI1 Normal Port4 Configuration - Priority |
| 1.3.6.1.4.1.4756.20.731.20.1.626 | Columnf2000EASMSTI2AggregatedPathCostRemoteA | read-write | current | f2000EAS Series card MSTI Port Configuration: MSTI2 Aggregated Ports Configuration - Path Cost Valid values are in the range 0 to 200000000. Setting 0 means Au… |
| 1.3.6.1.4.1.4756.20.731.20.1.627 | Columnf2000EASMSTI2AggregatedPriorityRemoteA | read-write | current | f2000EAS Series card MSTI Port Configuration: MSTI2 Aggregated Ports Configuration - Priority |
| 1.3.6.1.4.1.4756.20.731.20.1.628 | Columnf2000EASMSTI2Port1PathCostRemoteA | read-write | current | f2000EAS Series card MSTI Port Configuration: MSTI2 Normal Port1 Configuration - Path Cost Valid values are in the range 0 to 200000000. Setting 0 means Auto p… |
| 1.3.6.1.4.1.4756.20.731.20.1.629 | Columnf2000EASMSTI2Port1PriorityRemoteA | read-write | current | f2000EAS Series card MSTI Port Configuration: MSTI2 Normal Port1 Configuration - Priority |
| 1.3.6.1.4.1.4756.20.731.20.1.630 | Columnf2000EASMSTI2Port2PathCostRemoteA | read-write | current | f2000EAS Series card MSTI Port Configuration: MSTI2 Normal Port2 Configuration - Path Cost Valid values are in the range 0 to 200000000. Setting 0 means Auto p… |
| 1.3.6.1.4.1.4756.20.731.20.1.631 | Columnf2000EASMSTI2Port2PriorityRemoteA | read-write | current | f2000EAS Series card MSTI Port Configuration: MSTI2 Normal Port2 Configuration - Priority |
| 1.3.6.1.4.1.4756.20.731.20.1.632 | Columnf2000EASMSTI2Port3PathCostRemoteA | read-write | current | f2000EAS Series card MSTI Port Configuration: MSTI2 Normal Port3 Configuration - Path Cost Valid values are in the range 0 to 200000000. Setting 0 means Auto p… |
| 1.3.6.1.4.1.4756.20.731.20.1.633 | Columnf2000EASMSTI2Port3PriorityRemoteA | read-write | current | f2000EAS Series card MSTI Port Configuration: MSTI2 Normal Port3 Configuration - Priority |
| 1.3.6.1.4.1.4756.20.731.20.1.634 | Columnf2000EASMSTI2Port4PathCostRemoteA | read-write | current | f2000EAS Series card MSTI Port Configuration: MSTI2 Normal Port4 Configuration - Path Cost Valid values are in the range 0 to 200000000. Setting 0 means Auto p… |
| 1.3.6.1.4.1.4756.20.731.20.1.635 | Columnf2000EASMSTI2Port4PriorityRemoteA | read-write | current | f2000EAS Series card MSTI Port Configuration: MSTI2 Normal Port4 Configuration - Priority |
| 1.3.6.1.4.1.4756.20.731.20.1.636 | Columnf2000EASMSTI3AggregatedPathCostRemoteA | read-write | current | f2000EAS Series card MSTI Port Configuration: MSTI3 Aggregated Ports Configuration - Path Cost Valid values are in the range 0 to 200000000. Setting 0 means Au… |
| 1.3.6.1.4.1.4756.20.731.20.1.637 | Columnf2000EASMSTI3AggregatedPriorityRemoteA | read-write | current | f2000EAS Series card MSTI Port Configuration: MSTI3 Aggregated Ports Configuration - Priority |
| 1.3.6.1.4.1.4756.20.731.20.1.638 | Columnf2000EASMSTI3Port1PathCostRemoteA | read-write | current | f2000EAS Series card MSTI Port Configuration: MSTI3 Normal Port1 Configuration - Path Cost Valid values are in the range 0 to 200000000. Setting 0 means Auto p… |
| 1.3.6.1.4.1.4756.20.731.20.1.639 | Columnf2000EASMSTI3Port1PriorityRemoteA | read-write | current | f2000EAS Series card MSTI Port Configuration: MSTI3 Normal Port1 Configuration - Priority |
| 1.3.6.1.4.1.4756.20.731.20.1.640 | Columnf2000EASMSTI3Port2PathCostRemoteA | read-write | current | f2000EAS Series card MSTI Port Configuration: MSTI3 Normal Port2 Configuration - Path Cost Valid values are in the range 0 to 200000000. Setting 0 means Auto p… |
| 1.3.6.1.4.1.4756.20.731.20.1.641 | Columnf2000EASMSTI3Port2PriorityRemoteA | read-write | current | f2000EAS Series card MSTI Port Configuration: MSTI3 Normal Port2 Configuration - Priority |
| 1.3.6.1.4.1.4756.20.731.20.1.642 | Columnf2000EASMSTI3Port3PathCostRemoteA | read-write | current | f2000EAS Series card MSTI Port Configuration: MSTI1 Normal Port3 Configuration - Path Cost Valid values are in the range 0 to 200000000. Setting 0 means Auto p… |
| 1.3.6.1.4.1.4756.20.731.20.1.643 | Columnf2000EASMSTI3Port3PriorityRemoteA | read-write | current | f2000EAS Series card MSTI Port Configuration: MSTI3 Normal Port3 Configuration - Priority |
| 1.3.6.1.4.1.4756.20.731.20.1.644 | Columnf2000EASMSTI3Port4PathCostRemoteA | read-write | current | f2000EAS Series card MSTI Port Configuration: MSTI3 Normal Port4 Configuration - Path Cost Valid values are in the range 0 to 200000000. Setting 0 means Auto p… |
| 1.3.6.1.4.1.4756.20.731.20.1.645 | Columnf2000EASMSTI3Port4PriorityRemoteA | read-write | current | f2000EAS Series card MSTI Port Configuration: MSTI3 Normal Port4 Configuration - Priority |
| 1.3.6.1.4.1.4756.20.731.20.1.646 | Columnf2000EASMSTI4AggregatedPathCostRemoteA | read-write | current | f2000EAS Series card MSTI Port Configuration: MSTI4 Aggregated Ports Configuration - Path Cost Valid values are in the range 0 to 200000000. Setting 0 means Au… |
| 1.3.6.1.4.1.4756.20.731.20.1.647 | Columnf2000EASMSTI4AggregatedPriorityRemoteA | read-write | current | f2000EAS Series card MSTI Port Configuration: MSTI4 Aggregated Ports Configuration - Priority |
| 1.3.6.1.4.1.4756.20.731.20.1.648 | Columnf2000EASMSTI4Port1PathCostRemoteA | read-write | current | f2000EAS Series card MSTI Port Configuration: MSTI4 Normal Port1 Configuration - Path Cost Valid values are in the range 0 to 200000000. Setting 0 means Auto p… |
| 1.3.6.1.4.1.4756.20.731.20.1.649 | Columnf2000EASMSTI4Port1PriorityRemoteA | read-write | current | f2000EAS Series card MSTI Port Configuration: MSTI4 Normal Port1 Configuration - Priority |
| 1.3.6.1.4.1.4756.20.731.20.1.650 | Columnf2000EASMSTI4Port2PathCostRemoteA | read-write | current | f2000EAS Series card MSTI Port Configuration: MSTI4 Normal Port2 Configuration - Path Cost Valid values are in the range 0 to 200000000. Setting 0 means Auto p… |
| 1.3.6.1.4.1.4756.20.731.20.1.651 | Columnf2000EASMSTI4Port2PriorityRemoteA | read-write | current | f2000EAS Series card MSTI Port Configuration: MSTI4 Normal Port2 Configuration - Priority |
| 1.3.6.1.4.1.4756.20.731.20.1.652 | Columnf2000EASMSTI4Port3PathCostRemoteA | read-write | current | f2000EAS Series card MSTI Port Configuration: MSTI1 Normal Port3 Configuration - Path Cost Valid values are in the range 0 to 200000000. Setting 0 means Auto p… |
| 1.3.6.1.4.1.4756.20.731.20.1.653 | Columnf2000EASMSTI4Port3PriorityRemoteA | read-write | current | f2000EAS Series card MSTI Port Configuration: MSTI4 Normal Port3 Configuration - Priority |
| 1.3.6.1.4.1.4756.20.731.20.1.654 | Columnf2000EASMSTI4Port4PathCostRemoteA | read-write | current | f2000EAS Series card MSTI Port Configuration: MSTI4 Normal Port4 Configuration - Path Cost Valid values are in the range 0 to 200000000. Setting 0 means Auto p… |
| 1.3.6.1.4.1.4756.20.731.20.1.655 | Columnf2000EASMSTI4Port4PriorityRemoteA | read-write | current | f2000EAS Series card MSTI Port Configuration: MSTI4 Normal Port4 Configuration - Priority |
| 1.3.6.1.4.1.4756.20.731.20.1.656 | Columnf2000EASMSTI5AggregatedPathCostRemoteA | read-write | current | f2000EAS Series card MSTI Port Configuration: MSTI5 Aggregated Ports Configuration - Path Cost Valid values are in the range 0 to 200000000. Setting 0 means Au… |
| 1.3.6.1.4.1.4756.20.731.20.1.657 | Columnf2000EASMSTI5AggregatedPriorityRemoteA | read-write | current | f2000EAS Series card MSTI Port Configuration: MSTI5 Aggregated Ports Configuration - Priority |
| 1.3.6.1.4.1.4756.20.731.20.1.658 | Columnf2000EASMSTI5Port1PathCostRemoteA | read-write | current | f2000EAS Series card MSTI Port Configuration: MSTI5 Normal Port1 Configuration - Path Cost Valid values are in the range 0 to 200000000. Setting 0 means Auto p… |
| 1.3.6.1.4.1.4756.20.731.20.1.659 | Columnf2000EASMSTI5Port1PriorityRemoteA | read-write | current | f2000EAS Series card MSTI Port Configuration: MSTI5 Normal Port1 Configuration - Priority |
| 1.3.6.1.4.1.4756.20.731.20.1.660 | Columnf2000EASMSTI5Port2PathCostRemoteA | read-write | current | f2000EAS Series card MSTI Port Configuration: MSTI5 Normal Port2 Configuration - Path Cost Valid values are in the range 0 to 200000000. Setting 0 means Auto p… |
| 1.3.6.1.4.1.4756.20.731.20.1.661 | Columnf2000EASMSTI5Port2PriorityRemoteA | read-write | current | f2000EAS Series card MSTI Port Configuration: MSTI5 Normal Port2 Configuration - Priority |
| 1.3.6.1.4.1.4756.20.731.20.1.662 | Columnf2000EASMSTI5Port3PathCostRemoteA | read-write | current | f2000EAS Series card MSTI Port Configuration: MSTI5 Normal Port3 Configuration - Path Cost Valid values are in the range 0 to 200000000. Setting 0 means Auto p… |
| 1.3.6.1.4.1.4756.20.731.20.1.663 | Columnf2000EASMSTI5Port3PriorityRemoteA | read-write | current | f2000EAS Series card MSTI Port Configuration: MSTI5 Normal Port3 Configuration - Priority |
| 1.3.6.1.4.1.4756.20.731.20.1.664 | Columnf2000EASMSTI5Port4PathCostRemoteA | read-write | current | f2000EAS Series card MSTI Port Configuration: MSTI5 Normal Port4 Configuration - Path Cost Valid values are in the range 0 to 200000000. Setting 0 means Auto p… |
| 1.3.6.1.4.1.4756.20.731.20.1.665 | Columnf2000EASMSTI5Port4PriorityRemoteA | read-write | current | f2000EAS Series card MSTI Port Configuration: MSTI5 Normal Port4 Configuration - Priority |
| 1.3.6.1.4.1.4756.20.731.20.1.666 | Columnf2000EASMSTI6AggregatedPathCostRemoteA | read-write | current | f2000EAS Series card MSTI Port Configuration: MSTI6 Aggregated Ports Configuration - Path Cost Valid values are in the range 0 to 200000000. Setting 0 means Au… |
| 1.3.6.1.4.1.4756.20.731.20.1.667 | Columnf2000EASMSTI6AggregatedPriorityRemoteA | read-write | current | f2000EAS Series card MSTI Port Configuration: MSTI6 Aggregated Ports Configuration - Priority |
| 1.3.6.1.4.1.4756.20.731.20.1.668 | Columnf2000EASMSTI6Port1PathCostRemoteA | read-write | current | f2000EAS Series card MSTI Port Configuration: MSTI6 Normal Port1 Configuration - Path Cost Valid values are in the range 0 to 200000000. Setting 0 means Auto p… |
| 1.3.6.1.4.1.4756.20.731.20.1.669 | Columnf2000EASMSTI6Port1PriorityRemoteA | read-write | current | f2000EAS Series card MSTI Port Configuration: MSTI6 Normal Port1 Configuration - Priority |
| 1.3.6.1.4.1.4756.20.731.20.1.670 | Columnf2000EASMSTI6Port2PathCostRemoteA | read-write | current | f2000EAS Series card MSTI Port Configuration: MSTI6 Normal Port2 Configuration - Path Cost Valid values are in the range 0 to 200000000. Setting 0 means Auto p… |
| 1.3.6.1.4.1.4756.20.731.20.1.671 | Columnf2000EASMSTI6Port2PriorityRemoteA | read-write | current | f2000EAS Series card MSTI Port Configuration: MSTI6 Normal Port2 Configuration - Priority |
| 1.3.6.1.4.1.4756.20.731.20.1.672 | Columnf2000EASMSTI6Port3PathCostRemoteA | read-write | current | f2000EAS Series card MSTI Port Configuration: MSTI6 Normal Port3 Configuration - Path Cost Valid values are in the range 0 to 200000000. Setting 0 means Auto p… |
| 1.3.6.1.4.1.4756.20.731.20.1.673 | Columnf2000EASMSTI6Port3PriorityRemoteA | read-write | current | f2000EAS Series card MSTI Port Configuration: MSTI6 Normal Port3 Configuration - Priority |
| 1.3.6.1.4.1.4756.20.731.20.1.674 | Columnf2000EASMSTI6Port4PathCostRemoteA | read-write | current | f2000EAS Series card MSTI Port Configuration: MSTI6 Normal Port4 Configuration - Path Cost Valid values are in the range 0 to 200000000. Setting 0 means Auto p… |
| 1.3.6.1.4.1.4756.20.731.20.1.675 | Columnf2000EASMSTI6Port4PriorityRemoteA | read-write | current | f2000EAS Series card MSTI Port Configuration: MSTI6 Normal Port4 Configuration - Priority |
| 1.3.6.1.4.1.4756.20.731.20.1.676 | Columnf2000EASMSTI7AggregatedPathCostRemoteA | read-write | current | f2000EAS Series card MSTI Port Configuration: MSTI7 Aggregated Ports Configuration - Path Cost Valid values are in the range 0 to 200000000. Setting 0 means Au… |
| 1.3.6.1.4.1.4756.20.731.20.1.677 | Columnf2000EASMSTI7AggregatedPriorityRemoteA | read-write | current | f2000EAS Series card MSTI Port Configuration: MSTI7 Aggregated Ports Configuration - Priority |
| 1.3.6.1.4.1.4756.20.731.20.1.678 | Columnf2000EASMSTI7Port1PathCostRemoteA | read-write | current | f2000EAS Series card MSTI Port Configuration: MSTI1 Normal Port1 Configuration - Path Cost Valid values are in the range 0 to 200000000. Setting 0 means Auto p… |
| 1.3.6.1.4.1.4756.20.731.20.1.679 | Columnf2000EASMSTI7Port1PriorityRemoteA | read-write | current | f2000EAS Series card MSTI Port Configuration: MSTI1 Normal Port7 Configuration - Priority |
| 1.3.6.1.4.1.4756.20.731.20.1.680 | Columnf2000EASMSTI7Port2PathCostRemoteA | read-write | current | f2000EAS Series card MSTI Port Configuration: MSTI7 Normal Port2 Configuration - Path Cost Valid values are in the range 0 to 200000000. Setting 0 means Auto p… |
| 1.3.6.1.4.1.4756.20.731.20.1.681 | Columnf2000EASMSTI7Port2PriorityRemoteA | read-write | current | f2000EAS Series card MSTI Port Configuration: MSTI7 Normal Port2 Configuration - Priority |
| 1.3.6.1.4.1.4756.20.731.20.1.682 | Columnf2000EASMSTI7Port3PathCostRemoteA | read-write | current | f2000EAS Series card MSTI Port Configuration: MSTI7 Normal Port3 Configuration - Path Cost Valid values are in the range 0 to 200000000. Setting 0 means Auto p… |
| 1.3.6.1.4.1.4756.20.731.20.1.683 | Columnf2000EASMSTI7Port3PriorityRemoteA | read-write | current | f2000EAS Series card MSTI Port Configuration: MSTI7 Normal Port3 Configuration - Priority |
| 1.3.6.1.4.1.4756.20.731.20.1.684 | Columnf2000EASMSTI7Port4PathCostRemoteA | read-write | current | f2000EAS Series card MSTI Port Configuration: MSTI7 Normal Port4 Configuration - Path Cost Valid values are in the range 0 to 200000000. Setting 0 means Auto p… |
| 1.3.6.1.4.1.4756.20.731.20.1.685 | Columnf2000EASMSTI7Port4PriorityRemoteA | read-write | current | f2000EAS Series card MSTI Port Configuration: MSTI7 Normal Port4 Configuration - Priority |
| 1.3.6.1.4.1.4756.20.731.20.1.686 | Columnf2000EASCISTBridgeIDRemoteA | read-only | current | f2000EAS Series card STP Bridges status: CIST - Bridge ID |
| 1.3.6.1.4.1.4756.20.731.20.1.687 | Columnf2000EASCISTRootIDRemoteA | read-only | current | f2000EAS Series card STP Bridges status: CIST - Root ID |
| 1.3.6.1.4.1.4756.20.731.20.1.688 | Columnf2000EASCISTRootPortRemoteA | read-only | current | f2000EAS Series card STP Bridges status: CIST - Root Port |
| 1.3.6.1.4.1.4756.20.731.20.1.689 | Columnf2000EASCISTRootCostRemoteA | read-only | current | f2000EAS Series card STP Bridges status: CIST - Root Cost |
| 1.3.6.1.4.1.4756.20.731.20.1.690 | Columnf2000EASCISTTopologyFlagRemoteA | read-only | current | f2000EAS Series card STP Bridges status: CIST - Topology Flag |
| 1.3.6.1.4.1.4756.20.731.20.1.691 | Columnf2000EASCISTTopologyChangeLastRemoteA | read-only | current | f2000EAS Series card STP Bridges status: CIST - Topology Change Last |
| 1.3.6.1.4.1.4756.20.731.20.1.692 | Columnf2000EASMSTI1BridgeIDRemoteA | read-only | current | f2000EAS Series card STP Bridges status: MSTI1 - Bridge ID |
| 1.3.6.1.4.1.4756.20.731.20.1.693 | Columnf2000EASMSTI1RootIDRemoteA | read-only | current | f2000EAS Series card STP Bridges status: MSTI1 - Root ID |
| 1.3.6.1.4.1.4756.20.731.20.1.694 | Columnf2000EASMSTI1RootPortRemoteA | read-only | current | f2000EAS Series card STP Bridges status: MSTI1 - Root ID |
| 1.3.6.1.4.1.4756.20.731.20.1.695 | Columnf2000EASMSTI1RootCostRemoteA | read-only | current | f2000EAS Series card STP Bridges status: MSTI1 - Root Cost |
| 1.3.6.1.4.1.4756.20.731.20.1.696 | Columnf2000EASMSTI1TopologyFlagRemoteA | read-only | current | f2000EAS Series card STP Bridges status: MSTI1 - Topology Flag |
| 1.3.6.1.4.1.4756.20.731.20.1.697 | Columnf2000EASMSTI1TopologyChangeLastRemoteA | read-only | current | f2000EAS Series card STP Bridges status: MSTI1 - Topology Change Last |
| 1.3.6.1.4.1.4756.20.731.20.1.698 | Columnf2000EASMSTI2BridgeIDRemoteA | read-only | current | f2000EAS Series card STP Bridges status: MSTI2 - Bridge ID |
| 1.3.6.1.4.1.4756.20.731.20.1.699 | Columnf2000EASMSTI2RootIDRemoteA | read-only | current | f2000EAS Series card STP Bridges status: MSTI2 - Root ID |
| 1.3.6.1.4.1.4756.20.731.20.1.700 | Columnf2000EASMSTI2RootPortRemoteA | read-only | current | f2000EAS Series card STP Bridges status: MSTI2 - Root ID |
| 1.3.6.1.4.1.4756.20.731.20.1.701 | Columnf2000EASMSTI2RootCostRemoteA | read-only | current | f2000EAS Series card STP Bridges status: MSTI2 - Root Cost |
| 1.3.6.1.4.1.4756.20.731.20.1.702 | Columnf2000EASMSTI2TopologyFlagRemoteA | read-only | current | f2000EAS Series card STP Bridges status: MSTI2 - Topology Flag |
| 1.3.6.1.4.1.4756.20.731.20.1.703 | Columnf2000EASMSTI2TopologyChangeLastRemoteA | read-only | current | f2000EAS Series card STP Bridges status: MSTI2 - Topology Change Last |
| 1.3.6.1.4.1.4756.20.731.20.1.704 | Columnf2000EASMSTI3BridgeIDRemoteA | read-only | current | f2000EAS Series card STP Bridges status: MSTI3 - Bridge ID |
| 1.3.6.1.4.1.4756.20.731.20.1.705 | Columnf2000EASMSTI3RootIDRemoteA | read-only | current | f2000EAS Series card STP Bridges status: MSTI3 - Root ID |
| 1.3.6.1.4.1.4756.20.731.20.1.706 | Columnf2000EASMSTI3RootPortRemoteA | read-only | current | f2000EAS Series card STP Bridges status: MSTI3 - Root ID |
| 1.3.6.1.4.1.4756.20.731.20.1.707 | Columnf2000EASMSTI3RootCostRemoteA | read-only | current | f2000EAS Series card STP Bridges status: MSTI3 - Root Cost |
| 1.3.6.1.4.1.4756.20.731.20.1.708 | Columnf2000EASMSTI3TopologyFlagRemoteA | read-only | current | f2000EAS Series card STP Bridges status: MSTI3 - Topology Flag |
| 1.3.6.1.4.1.4756.20.731.20.1.709 | Columnf2000EASMSTI3TopologyChangeLastRemoteA | read-only | current | f2000EAS Series card STP Bridges status: MSTI3 - Topology Change Last |
| 1.3.6.1.4.1.4756.20.731.20.1.710 | Columnf2000EASMSTI4BridgeIDRemoteA | read-only | current | f2000EAS Series card STP Bridges status: MSTI4 - Bridge ID |
| 1.3.6.1.4.1.4756.20.731.20.1.711 | Columnf2000EASMSTI4RootIDRemoteA | read-only | current | f2000EAS Series card STP Bridges status: MSTI4 - Root ID |
| 1.3.6.1.4.1.4756.20.731.20.1.712 | Columnf2000EASMSTI4RootPortRemoteA | read-only | current | f2000EAS Series card STP Bridges status: MSTI4 - Root ID |
| 1.3.6.1.4.1.4756.20.731.20.1.713 | Columnf2000EASMSTI4RootCostRemoteA | read-only | current | f2000EAS Series card STP Bridges status: MSTI4 - Root Cost |
| 1.3.6.1.4.1.4756.20.731.20.1.714 | Columnf2000EASMSTI4TopologyFlagRemoteA | read-only | current | f2000EAS Series card STP Bridges status: MSTI4 - Topology Flag |
| 1.3.6.1.4.1.4756.20.731.20.1.715 | Columnf2000EASMSTI4TopologyChangeLastRemoteA | read-only | current | f2000EAS Series card STP Bridges status: MSTI4 - Topology Change Last |
| 1.3.6.1.4.1.4756.20.731.20.1.716 | Columnf2000EASMSTI5BridgeIDRemoteA | read-only | current | f2000EAS Series card STP Bridges status: MSTI5 - Bridge ID |
| 1.3.6.1.4.1.4756.20.731.20.1.717 | Columnf2000EASMSTI5RootIDRemoteA | read-only | current | f2000EAS Series card STP Bridges status: MSTI5 - Root ID |
| 1.3.6.1.4.1.4756.20.731.20.1.718 | Columnf2000EASMSTI5RootPortRemoteA | read-only | current | f2000EAS Series card STP Bridges status: MSTI5 - Root ID |
| 1.3.6.1.4.1.4756.20.731.20.1.719 | Columnf2000EASMSTI5RootCostRemoteA | read-only | current | f2000EAS Series card STP Bridges status: MSTI5 - Root Cost |
| 1.3.6.1.4.1.4756.20.731.20.1.720 | Columnf2000EASMSTI5TopologyFlagRemoteA | read-only | current | f2000EAS Series card STP Bridges status: MSTI5 - Topology Flag |
| 1.3.6.1.4.1.4756.20.731.20.1.721 | Columnf2000EASMSTI5TopologyChangeLastRemoteA | read-only | current | f2000EAS Series card STP Bridges status: MSTI5 - Topology Change Last |
| 1.3.6.1.4.1.4756.20.731.20.1.722 | Columnf2000EASMSTI6BridgeIDRemoteA | read-only | current | f2000EAS Series card STP Bridges status: MSTI6 - Bridge ID |
| 1.3.6.1.4.1.4756.20.731.20.1.723 | Columnf2000EASMSTI6RootIDRemoteA | read-only | current | f2000EAS Series card STP Bridges status: MSTI6 - Root ID |
| 1.3.6.1.4.1.4756.20.731.20.1.724 | Columnf2000EASMSTI6RootPortRemoteA | read-only | current | f2000EAS Series card STP Bridges status: MSTI6 - Root ID |
| 1.3.6.1.4.1.4756.20.731.20.1.725 | Columnf2000EASMSTI6RootCostRemoteA | read-only | current | f2000EAS Series card STP Bridges status: MSTI6 - Root Cost |
| 1.3.6.1.4.1.4756.20.731.20.1.726 | Columnf2000EASMSTI6TopologyFlagRemoteA | read-only | current | f2000EAS Series card STP Bridges status: MSTI6 - Topology Flag |
| 1.3.6.1.4.1.4756.20.731.20.1.727 | Columnf2000EASMSTI6TopologyChangeLastRemoteA | read-only | current | f2000EAS Series card STP Bridges status: MSTI6 - Topology Change Last |
| 1.3.6.1.4.1.4756.20.731.20.1.728 | Columnf2000EASMSTI7BridgeIDRemoteA | read-only | current | f2000EAS Series card STP Bridges status: MSTI7 - Bridge ID |
| 1.3.6.1.4.1.4756.20.731.20.1.729 | Columnf2000EASMSTI7RootIDRemoteA | read-only | current | f2000EAS Series card STP Bridges status: MSTI7 - Root ID |
| 1.3.6.1.4.1.4756.20.731.20.1.730 | Columnf2000EASMSTI7RootPortRemoteA | read-only | current | f2000EAS Series card STP Bridges status: MSTI7 - Root ID |
| 1.3.6.1.4.1.4756.20.731.20.1.731 | Columnf2000EASMSTI7RootCostRemoteA | read-only | current | f2000EAS Series card STP Bridges status: MSTI7 - Root Cost |
| 1.3.6.1.4.1.4756.20.731.20.1.732 | Columnf2000EASMSTI7TopologyFlagRemoteA | read-only | current | f2000EAS Series card STP Bridges status: MSTI7 - Topology Flag |
| 1.3.6.1.4.1.4756.20.731.20.1.733 | Columnf2000EASMSTI7TopologyChangeLastRemoteA | read-only | current | f2000EAS Series card STP Bridges status: MSTI7 - Topology Change Last |
| 1.3.6.1.4.1.4756.20.731.20.1.734 | Columnf2000EASSTPPortStatusInst1PortRemoteA | read-only | current | f2000EAS Series card STP Port status: Instance1 - Port |
| 1.3.6.1.4.1.4756.20.731.20.1.735 | Columnf2000EASSTPPortStatusInst1CISTRoleRemoteA | read-only | current | f2000EAS Series card STP Port status: Instance1 - CIST Role |
| 1.3.6.1.4.1.4756.20.731.20.1.736 | Columnf2000EASSTPPortStatusInst1CISTStateRemoteA | read-only | current | f2000EAS Series card STP Port status: Instance1 - CIST State |
| 1.3.6.1.4.1.4756.20.731.20.1.737 | Columnf2000EASSTPPortStatusInst1UptimeRemoteA | read-only | current | f2000EAS Series card STP Port status: Instance1 -Uptime |
| 1.3.6.1.4.1.4756.20.731.20.1.738 | Columnf2000EASSTPPortStatusInst2PortRemoteA | read-only | current | f2000EAS Series card STP Port status: Instance2 - Port |
| 1.3.6.1.4.1.4756.20.731.20.1.739 | Columnf2000EASSTPPortStatusInst2CISTRoleRemoteA | read-only | current | f2000EAS Series card STP Port status: Instance2 - CIST Role |
| 1.3.6.1.4.1.4756.20.731.20.1.740 | Columnf2000EASSTPPortStatusInst2CISTStateRemoteA | read-only | current | f2000EAS Series card STP Port status: Instance2 - CIST State |
| 1.3.6.1.4.1.4756.20.731.20.1.741 | Columnf2000EASSTPPortStatusInst2UptimeRemoteA | read-only | current | f2000EAS Series card STP Port status: Instance2 -Uptime |
| 1.3.6.1.4.1.4756.20.731.20.1.742 | Columnf2000EASSTPPortStatusInst3PortRemoteA | read-only | current | f2000EAS Series card STP Port status: Instance3 - Port |
| 1.3.6.1.4.1.4756.20.731.20.1.743 | Columnf2000EASSTPPortStatusInst3CISTRoleRemoteA | read-only | current | f2000EAS Series card STP Port status: Instance3 - CIST Role |
| 1.3.6.1.4.1.4756.20.731.20.1.744 | Columnf2000EASSTPPortStatusInst3CISTStateRemoteA | read-only | current | f2000EAS Series card STP Port status: Instance3 - CIST State |
| 1.3.6.1.4.1.4756.20.731.20.1.745 | Columnf2000EASSTPPortStatusInst3UptimeRemoteA | read-only | current | f2000EAS Series card STP Port status: Instance3 -Uptime |
| 1.3.6.1.4.1.4756.20.731.20.1.746 | Columnf2000EASSTPPortStatusInst4PortRemoteA | read-only | current | f2000EAS Series card STP Port status: Instance4 - Port |
| 1.3.6.1.4.1.4756.20.731.20.1.747 | Columnf2000EASSTPPortStatusInst4CISTRoleRemoteA | read-only | current | f2000EAS Series card STP Port status: Instance4 - CIST Role |
| 1.3.6.1.4.1.4756.20.731.20.1.748 | Columnf2000EASSTPPortStatusInst4CISTStateRemoteA | read-only | current | f2000EAS Series card STP Port status: Instance4 - CIST State |
| 1.3.6.1.4.1.4756.20.731.20.1.749 | Columnf2000EASSTPPortStatusInst4UptimeRemoteA | read-only | current | f2000EAS Series card STP Port status: Instance4 -Uptime |
| 1.3.6.1.4.1.4756.20.731.20.1.750 | Columnf2000EASSTPStatisticsPort1TxMSTPRemoteA | read-only | current | f2000EAS Series card STP Port Statistics: Port1 -Transmitted MSTP |
| 1.3.6.1.4.1.4756.20.731.20.1.751 | Columnf2000EASSTPStatisticsPort1TxRSTPRemoteA | read-only | current | f2000EAS Series card STP Port Statistics: Port1 -Transmitted RSTP |
| 1.3.6.1.4.1.4756.20.731.20.1.752 | Columnf2000EASSTPStatisticsPort1TxSTPRemoteA | read-only | current | f2000EAS Series card STP Port Statistics: Port1 -Transmitted RSTP |
| 1.3.6.1.4.1.4756.20.731.20.1.753 | Columnf2000EASSTPStatisticsPort1TxTCNRemoteA | read-only | current | f2000EAS Series card STP Port Statistics: Port1 -Transmitted RSTP |
| 1.3.6.1.4.1.4756.20.731.20.1.754 | Columnf2000EASSTPStatisticsPort1RxMSTPRemoteA | read-only | current | f2000EAS Series card STP Port Statistics: Port1 -Received MSTP |
| 1.3.6.1.4.1.4756.20.731.20.1.755 | Columnf2000EASSTPStatisticsPort1RxRSTPRemoteA | read-only | current | f2000EAS Series card STP Port Statistics: Port1 -Received RSTP |
| 1.3.6.1.4.1.4756.20.731.20.1.756 | Columnf2000EASSTPStatisticsPort1RxSTPRemoteA | read-only | current | f2000EAS Series card STP Port Statistics: Port1 -Received RSTP |
| 1.3.6.1.4.1.4756.20.731.20.1.757 | Columnf2000EASSTPStatisticsPort1RxTCNRemoteA | read-only | current | f2000EAS Series card STP Port Statistics: Port1 -Received RSTP |
| 1.3.6.1.4.1.4756.20.731.20.1.758 | Columnf2000EASSTPStatisticsPort1DiscardUnknowRemoteA | read-only | current | f2000EAS Series card STP Port Statistics: Port1 -Discarded Unknown |
| 1.3.6.1.4.1.4756.20.731.20.1.759 | Columnf2000EASSTPStatisticsPort1DiscardIllegalRemoteA | read-only | current | f2000EAS Series card STP Port Statistics: Port1 -Discarded Illegal |
| 1.3.6.1.4.1.4756.20.731.20.1.760 | Columnf2000EASSTPStatisticsPort2TxMSTPRemoteA | read-only | current | f2000EAS Series card STP Port Statistics: Port2 -Transmitted MSTP |
| 1.3.6.1.4.1.4756.20.731.20.1.761 | Columnf2000EASSTPStatisticsPort2TxRSTPRemoteA | read-only | current | f2000EAS Series card STP Port Statistics: Port2 -Transmitted RSTP |
| 1.3.6.1.4.1.4756.20.731.20.1.762 | Columnf2000EASSTPStatisticsPort2TxSTPRemoteA | read-only | current | f2000EAS Series card STP Port Statistics: Port2 -Transmitted RSTP |
| 1.3.6.1.4.1.4756.20.731.20.1.763 | Columnf2000EASSTPStatisticsPort2TxTCNRemoteA | read-only | current | f2000EAS Series card STP Port Statistics: Port2 -Transmitted RSTP |
| 1.3.6.1.4.1.4756.20.731.20.1.764 | Columnf2000EASSTPStatisticsPort2RxMSTPRemoteA | read-only | current | f2000EAS Series card STP Port Statistics: Port2 -Received MSTP |
| 1.3.6.1.4.1.4756.20.731.20.1.765 | Columnf2000EASSTPStatisticsPort2RxRSTPRemoteA | read-only | current | f2000EAS Series card STP Port Statistics: Port1 -Received RSTP |
| 1.3.6.1.4.1.4756.20.731.20.1.766 | Columnf2000EASSTPStatisticsPort2RxSTPRemoteA | read-only | current | f2000EAS Series card STP Port Statistics: Port2 -Received RSTP |
| 1.3.6.1.4.1.4756.20.731.20.1.767 | Columnf2000EASSTPStatisticsPort2RxTCNRemoteA | read-only | current | f2000EAS Series card STP Port Statistics: Port2 -Received RSTP |
| 1.3.6.1.4.1.4756.20.731.20.1.768 | Columnf2000EASSTPStatisticsPort2DiscardUnknowRemoteA | read-only | current | f2000EAS Series card STP Port Statistics: Port2 -Discarded Unknown |
| 1.3.6.1.4.1.4756.20.731.20.1.769 | Columnf2000EASSTPStatisticsPort2DiscardIllegalRemoteA | read-only | current | f2000EAS Series card STP Port Statistics: Port2 -Discarded Illegal |
| 1.3.6.1.4.1.4756.20.731.20.1.770 | Columnf2000EASSTPStatisticsPort3TxMSTPRemoteA | read-only | current | f2000EAS Series card STP Port Statistics: Port3 -Transmitted MSTP |
| 1.3.6.1.4.1.4756.20.731.20.1.771 | Columnf2000EASSTPStatisticsPort3TxRSTPRemoteA | read-only | current | f2000EAS Series card STP Port Statistics: Port3 -Transmitted RSTP |
| 1.3.6.1.4.1.4756.20.731.20.1.772 | Columnf2000EASSTPStatisticsPort3TxSTPRemoteA | read-only | current | f2000EAS Series card STP Port Statistics: Port3 -Transmitted RSTP |
| 1.3.6.1.4.1.4756.20.731.20.1.773 | Columnf2000EASSTPStatisticsPort3TxTCNRemoteA | read-only | current | f2000EAS Series card STP Port Statistics: Port3 -Transmitted RSTP |
| 1.3.6.1.4.1.4756.20.731.20.1.774 | Columnf2000EASSTPStatisticsPort3RxMSTPRemoteA | read-only | current | f2000EAS Series card STP Port Statistics: Port3 -Received MSTP |
| 1.3.6.1.4.1.4756.20.731.20.1.775 | Columnf2000EASSTPStatisticsPort3RxRSTPRemoteA | read-only | current | f2000EAS Series card STP Port Statistics: Port3 -Received RSTP |
| 1.3.6.1.4.1.4756.20.731.20.1.776 | Columnf2000EASSTPStatisticsPort3RxSTPRemoteA | read-only | current | f2000EAS Series card STP Port Statistics: Port3 -Received RSTP |
| 1.3.6.1.4.1.4756.20.731.20.1.777 | Columnf2000EASSTPStatisticsPort3RxTCNRemoteA | read-only | current | f2000EAS Series card STP Port Statistics: Port3 -Received RSTP |
| 1.3.6.1.4.1.4756.20.731.20.1.778 | Columnf2000EASSTPStatisticsPort3DiscardUnknowRemoteA | read-only | current | f2000EAS Series card STP Port Statistics: Port3 -Discarded Unknown |
| 1.3.6.1.4.1.4756.20.731.20.1.779 | Columnf2000EASSTPStatisticsPort3DiscardIllegalRemoteA | read-only | current | f2000EAS Series card STP Port Statistics: Port3 -Discarded Illegal |
| 1.3.6.1.4.1.4756.20.731.20.1.780 | Columnf2000EASSTPStatisticsPort4TxMSTPRemoteA | read-only | current | f2000EAS Series card STP Port Statistics: Port4 -Transmitted MSTP |
| 1.3.6.1.4.1.4756.20.731.20.1.781 | Columnf2000EASSTPStatisticsPort4TxRSTPRemoteA | read-only | current | f2000EAS Series card STP Port Statistics: Port4 -Transmitted RSTP |
| 1.3.6.1.4.1.4756.20.731.20.1.782 | Columnf2000EASSTPStatisticsPort4TxSTPRemoteA | read-only | current | f2000EAS Series card STP Port Statistics: Port4 -Transmitted RSTP |
| 1.3.6.1.4.1.4756.20.731.20.1.783 | Columnf2000EASSTPStatisticsPort4TxTCNRemoteA | read-only | current | f2000EAS Series card STP Port Statistics: Port4 -Transmitted RSTP |
| 1.3.6.1.4.1.4756.20.731.20.1.784 | Columnf2000EASSTPStatisticsPort4RxMSTPRemoteA | read-only | current | f2000EAS Series card STP Port Statistics: Port4 -Received MSTP |
| 1.3.6.1.4.1.4756.20.731.20.1.785 | Columnf2000EASSTPStatisticsPort4RxRSTPRemoteA | read-only | current | f2000EAS Series card STP Port Statistics: Port4 -Received RSTP |
| 1.3.6.1.4.1.4756.20.731.20.1.786 | Columnf2000EASSTPStatisticsPort4RxSTPRemoteA | read-only | current | f2000EAS Series card STP Port Statistics: Port4 -Received RSTP |
| 1.3.6.1.4.1.4756.20.731.20.1.787 | Columnf2000EASSTPStatisticsPort4RxTCNRemoteA | read-only | current | f2000EAS Series card STP Port Statistics: Port4 -Received RSTP |
| 1.3.6.1.4.1.4756.20.731.20.1.788 | Columnf2000EASSTPStatisticsPort4DiscardUnknowRemoteA | read-only | current | f2000EAS Series card STP Port Statistics: Port4 -Discarded Unknown |
| 1.3.6.1.4.1.4756.20.731.20.1.789 | Columnf2000EASSTPStatisticsPort4DiscardIllegalRemoteA | read-only | current | f2000EAS Series card STP Port Statistics: Port4 -Discarded Illegal |
| 1.3.6.1.4.1.4756.20.731.20.1.790 | Columnf2000EASSTPStatisticsPortClearCounterRemoteA | read-write | current | f2000EAS Series card STP Port Statistics: Clear Counters 0: OFff 1: Action |
| 1.3.6.1.4.1.4756.20.731.20.1.791 | Columnf2000EASAllowedAccessVLANsRemoteA | read-write | current | f2000EAS Series card Global VLAN Configuration: Allowed Access VLANs By default, only VLAN 1 is enabled. More VLANs may be created by using a list syntax where… |
| 1.3.6.1.4.1.4756.20.731.20.1.792 | Columnf2000EASVlanEthertypeRemoteA | read-write | current | f2000EAS Series card Global VLAN Configuration: Ethertype for Custom S-ports The format of 'Ethernet Type' is restricted to 0x600-0xFFFF |
| 1.3.6.1.4.1.4756.20.731.20.1.793 | Columnf2000EASPort1VlanModeRemoteA | read-write | current | f2000EAS Series card Port VLAN Configuration : Port1 - Mode 0: Access 1: Trunk 2: Hybrid |
| 1.3.6.1.4.1.4756.20.731.20.1.794 | Columnf2000EASPort1VlanIDRemoteA | read-write | current | f2000EAS Series card Port VLAN Configuration : Port1 - VLAN ID |
| 1.3.6.1.4.1.4756.20.731.20.1.795 | Columnf2000EASPort1VlanTypeRemoteA | read-write | current | f2000EAS Series card Port VLAN Configuration : Port1 - VLAN Type 0: Unaware 1: C-port 2: S-port 3: S-custom-port |
| 1.3.6.1.4.1.4756.20.731.20.1.796 | Columnf2000EASPort1VlanIngressFilteringRemoteA | read-write | current | f2000EAS Series card Port VLAN Configuration : Port1 - Ingress Filtering 0: Off 1: On |
| 1.3.6.1.4.1.4756.20.731.20.1.797 | Columnf2000EASPort1VlanIngressAcceptanceRemoteA | read-write | current | f2000EAS Series card Port VLAN Configuration : Port1 - Ingress Acceptance 0: Tagged and untagged 1: Tagged only 2: Untagged only |
| 1.3.6.1.4.1.4756.20.731.20.1.798 | Columnf2000EASPort1VlanEgressTaggingRemoteA | read-write | current | f2000EAS Series card Port VLAN Configuration : Port1 - Egress Tagging 0: Untag port vlan 1: Tag all 2: Untag all |
| 1.3.6.1.4.1.4756.20.731.20.1.799 | Columnf2000EASPort1VlanEgressTaggedSpecificallyUntagRemoteA | read-write | current | Ports in Hybrid mode may specify the tagging of frames with VID on egress, which overrules the Egress Tagging setting. Frames classified to these VLANs are tra… |
| 1.3.6.1.4.1.4756.20.731.20.1.800 | Columnf2000EASPort1VlanEgressTaggedSpecificallyCtagRemoteA | read-write | current | Ports in Hybrid mode may specify the tagging of frames with VID on egress, which overrules the Egress Tagging setting. Frames classified to these VLANs are tra… |
| 1.3.6.1.4.1.4756.20.731.20.1.801 | Columnf2000EASPort1VlanEgressTaggedSpecificallyStagRemoteA | read-write | current | Ports in Hybrid mode may specify the tagging of frames with VID on egress, which overrules the Egress Tagging setting. Frames classified to these VLANs are tra… |
| 1.3.6.1.4.1.4756.20.731.20.1.802 | Columnf2000EASPort1VlanEgressTaggedSpecificallySCtagRemoteA | read-write | current | Ports in Hybrid mode may specify the tagging of frames with VID on egress, which overrules the Egress Tagging setting. Frames classified to these VLANs are tra… |
| 1.3.6.1.4.1.4756.20.731.20.1.803 | Columnf2000EASPort1AllowedVLANSRemoteA | read-write | current | f2000EAS Series card Global VLAN Configuration: Port1 - Allowed VLANs By default, only VLAN 1 is enabled. More VLANs may be created by using a list syntax wher… |
| 1.3.6.1.4.1.4756.20.731.20.1.804 | Columnf2000EASPort2VlanModeRemoteA | read-write | current | f2000EAS Series card Port VLAN Configuration : Port2 - Mode 0: Access 1: Trunk 2: Hybrid |
| 1.3.6.1.4.1.4756.20.731.20.1.805 | Columnf2000EASPort2VlanIDRemoteA | read-write | current | f2000EAS Series card Port VLAN Configuration : Port2 - VLAN ID |
| 1.3.6.1.4.1.4756.20.731.20.1.806 | Columnf2000EASPort2VlanTypeRemoteA | read-write | current | f2000EAS Series card Port VLAN Configuration : Port2 - VLAN Type 0: Unaware 1: C-port 2: S-port 3: S-custom-port |
| 1.3.6.1.4.1.4756.20.731.20.1.807 | Columnf2000EASPort2VlanIngressFilteringRemoteA | read-write | current | f2000EAS Series card Port VLAN Configuration : Port2 - Ingress Filtering 0: Off 1: On |
| 1.3.6.1.4.1.4756.20.731.20.1.808 | Columnf2000EASPort2VlanIngressAcceptanceRemoteA | read-write | current | f2000EAS Series card Port VLAN Configuration : Por2 - Ingress Acceptance 0: Tagged and untagged 1: Tagged only 2: Untagged only |
| 1.3.6.1.4.1.4756.20.731.20.1.809 | Columnf2000EASPort2VlanEgressTaggingRemoteA | read-write | current | f2000EAS Series card Port VLAN Configuration : Port2 - Egress Tagging 0: Untag port vlan 1: Tag all 2: Untag all |
| 1.3.6.1.4.1.4756.20.731.20.1.810 | Columnf2000EASPort2VlanEgressTaggedSpecificallyUntagRemoteA | read-write | current | Ports in Hybrid mode may specify the tagging of frames with VID on egress, which overrules the Egress Tagging setting. Frames classified to these VLANs are tra… |
| 1.3.6.1.4.1.4756.20.731.20.1.811 | Columnf2000EASPort2VlanEgressTaggedSpecificallyCtagRemoteA | read-write | current | Ports in Hybrid mode may specify the tagging of frames with VID on egress, which overrules the Egress Tagging setting. Frames classified to these VLANs are tra… |
| 1.3.6.1.4.1.4756.20.731.20.1.812 | Columnf2000EASPort2VlanEgressTaggedSpecificallyStagRemoteA | read-write | current | Ports in Hybrid mode may specify the tagging of frames with VID on egress, which overrules the Egress Tagging setting. Frames classified to these VLANs are tra… |
| 1.3.6.1.4.1.4756.20.731.20.1.813 | Columnf2000EASPort2VlanEgressTaggedSpecificallySCtagRemoteA | read-write | current | Ports in Hybrid mode may specify the tagging of frames with VID on egress, which overrules the Egress Tagging setting. Frames classified to these VLANs are tra… |
| 1.3.6.1.4.1.4756.20.731.20.1.814 | Columnf2000EASPort2AllowedVLANSRemoteA | read-write | current | f2000EAS Series card Global VLAN Configuration: Port2 - Allowed VLANs By default, only VLAN 1 is enabled. More VLANs may be created by using a list syntax wher… |
| 1.3.6.1.4.1.4756.20.731.20.1.815 | Columnf2000EASPort3VlanModeRemoteA | read-write | current | f2000EAS Series card Port VLAN Configuration : Port3 - Mode 0: Access 1: Trunk 2: Hybrid |
| 1.3.6.1.4.1.4756.20.731.20.1.816 | Columnf2000EASPort3VlanIDRemoteA | read-write | current | f2000EAS Series card Port VLAN Configuration : Port3 - VLAN ID |
| 1.3.6.1.4.1.4756.20.731.20.1.817 | Columnf2000EASPort3VlanTypeRemoteA | read-write | current | f2000EAS Series card Port VLAN Configuration : Port3 - VLAN Type 0: Unaware 1: C-port 2: S-port 3: S-custom-port |
| 1.3.6.1.4.1.4756.20.731.20.1.818 | Columnf2000EASPort3VlanIngressFilteringRemoteA | read-write | current | f2000EAS Series card Port VLAN Configuration : Port3 - Ingress Filtering 0: Off 1: On |
| 1.3.6.1.4.1.4756.20.731.20.1.819 | Columnf2000EASPort3VlanIngressAcceptanceRemoteA | read-write | current | f2000EAS Series card Port VLAN Configuration : Port3 - Ingress Acceptance 0: Tagged and untagged 1: Tagged only 2: Untagged only |
| 1.3.6.1.4.1.4756.20.731.20.1.820 | Columnf2000EASPort3VlanEgressTaggingRemoteA | read-write | current | f2000EAS Series card Port VLAN Configuration : Port3 - Egress Tagging 0: Untag port vlan 1: Tag all 2: Untag all |
| 1.3.6.1.4.1.4756.20.731.20.1.821 | Columnf2000EASPort3VlanEgressTaggedSpecificallyUntagRemoteA | read-write | current | Ports in Hybrid mode may specify the tagging of frames with VID on egress, which overrules the Egress Tagging setting. Frames classified to these VLANs are tra… |
| 1.3.6.1.4.1.4756.20.731.20.1.822 | Columnf2000EASPort3VlanEgressTaggedSpecificallyCtagRemoteA | read-write | current | Ports in Hybrid mode may specify the tagging of frames with VID on egress, which overrules the Egress Tagging setting. Frames classified to these VLANs are tra… |
| 1.3.6.1.4.1.4756.20.731.20.1.823 | Columnf2000EASPort3VlanEgressTaggedSpecificallyStagRemoteA | read-write | current | Ports in Hybrid mode may specify the tagging of frames with VID on egress, which overrules the Egress Tagging setting. Frames classified to these VLANs are tra… |
| 1.3.6.1.4.1.4756.20.731.20.1.824 | Columnf2000EASPort3VlanEgressTaggedSpecificallySCtagRemoteA | read-write | current | Ports in Hybrid mode may specify the tagging of frames with VID on egress, which overrules the Egress Tagging setting. Frames classified to these VLANs are tra… |
| 1.3.6.1.4.1.4756.20.731.20.1.825 | Columnf2000EASPort3AllowedVLANSRemoteA | read-write | current | f2000EAS Series card Global VLAN Configuration: Port3 - Allowed VLANs By default, only VLAN 1 is enabled. More VLANs may be created by using a list syntax wher… |
| 1.3.6.1.4.1.4756.20.731.20.1.826 | Columnf2000EASPort4VlanModeRemoteA | read-write | current | f2000EAS Series card Port VLAN Configuration : Port4 - Mode 0: Access 1: Trunk 2: Hybrid |
| 1.3.6.1.4.1.4756.20.731.20.1.827 | Columnf2000EASPort4VlanIDRemoteA | read-write | current | f2000EAS Series card Port VLAN Configuration : Port4 - VLAN ID |
| 1.3.6.1.4.1.4756.20.731.20.1.828 | Columnf2000EASPort4VlanTypeRemoteA | read-write | current | f2000EAS Series card Port VLAN Configuration : Port4 - VLAN Type 0: Unaware 1: C-port 2: S-port 3: S-custom-port |
| 1.3.6.1.4.1.4756.20.731.20.1.829 | Columnf2000EASPort4VlanIngressFilteringRemoteA | read-write | current | f2000EAS Series card Port VLAN Configuration : Port4 - Ingress Filtering 0: Off 1: On |
| 1.3.6.1.4.1.4756.20.731.20.1.830 | Columnf2000EASPort4VlanIngressAcceptanceRemoteA | read-write | current | f2000EAS Series card Port VLAN Configuration : Port4 - Ingress Acceptance 0: Tagged and untagged 1: Tagged only 2: Untagged only |
| 1.3.6.1.4.1.4756.20.731.20.1.831 | Columnf2000EASPort4VlanEgressTaggingRemoteA | read-write | current | f2000EAS Series card Port VLAN Configuration : Port4 - Egress Tagging 0: Untag port vlan 1: Tag all 2: Untag all |
| 1.3.6.1.4.1.4756.20.731.20.1.832 | Columnf2000EASPort4VlanEgressTaggedSpecificallyUntagRemoteA | read-write | current | Ports in Hybrid mode may specify the tagging of frames with VID on egress, which overrules the Egress Tagging setting. Frames classified to these VLANs are tra… |
| 1.3.6.1.4.1.4756.20.731.20.1.833 | Columnf2000EASPort4VlanEgressTaggedSpecificallyCtagRemoteA | read-write | current | Ports in Hybrid mode may specify the tagging of frames with VID on egress, which overrules the Egress Tagging setting. Frames classified to these VLANs are tra… |
| 1.3.6.1.4.1.4756.20.731.20.1.834 | Columnf2000EASPort4VlanEgressTaggedSpecificallyStagRemoteA | read-write | current | Ports in Hybrid mode may specify the tagging of frames with VID on egress, which overrules the Egress Tagging setting. Frames classified to these VLANs are tra… |
| 1.3.6.1.4.1.4756.20.731.20.1.835 | Columnf2000EASPort4VlanEgressTaggedSpecificallySCtagRemoteA | read-write | current | Ports in Hybrid mode may specify the tagging of frames with VID on egress, which overrules the Egress Tagging setting. Frames classified to these VLANs are tra… |
| 1.3.6.1.4.1.4756.20.731.20.1.836 | Columnf2000EASPort4AllowedVLANSRemoteA | read-write | current | f2000EAS Series card Global VLAN Configuration: Port4 - Allowed VLANs By default, only VLAN 1 is enabled. More VLANs may be created by using a list syntax wher… |
| 1.3.6.1.4.1.4756.20.731.20.1.837 | Columnf2000EASQOSPort1IngressRemoteA | read-write | current | f2000EAS Series card QOS Port1 Ingress Enabled 0: NO 1: YES |
| 1.3.6.1.4.1.4756.20.731.20.1.838 | Columnf2000EASQOSPort1IngressRateRemoteA | read-write | current | f2000EAS Series card QOS Port1 Ingress Rate |
| 1.3.6.1.4.1.4756.20.731.20.1.839 | Columnf2000EASQOSPort1IngressRateUnitRemoteA | read-write | current | f2000EAS Series card QOS Port1 Ingress Rate Unit 0: Kbps 1: Mbps 2: fps 3: kfps |
| 1.3.6.1.4.1.4756.20.731.20.1.840 | Columnf2000EASQOSPort1IngressBurstSizeRemoteA | read-write | current | f2000EAS Series card QOS Port1 Ingress Burst Size |
| 1.3.6.1.4.1.4756.20.731.20.1.841 | Columnf2000EASQOSPort2IngressRemoteA | read-write | current | f2000EAS Series card QOS Port2 Ingress Enabled 0: NO 1: YES |
| 1.3.6.1.4.1.4756.20.731.20.1.842 | Columnf2000EASQOSPort2IngressRateRemoteA | read-write | current | f2000EAS Series card QOS Port2 Ingress Rate |
| 1.3.6.1.4.1.4756.20.731.20.1.843 | Columnf2000EASQOSPort2IngressRateUnitRemoteA | read-write | current | f2000EAS Series card QOS Port2 Ingress Rate Unit 0: Kbps 1: Mbps 2: fps 3: kfps |
| 1.3.6.1.4.1.4756.20.731.20.1.844 | Columnf2000EASQOSPort2IngressBurstSizeRemoteA | read-write | current | f2000EAS Series card QOS Port2 Ingress Burst Size |
| 1.3.6.1.4.1.4756.20.731.20.1.845 | Columnf2000EASQOSPort3IngressRemoteA | read-write | current | f2000EAS Series card QOS Port3 Ingress Enabled 0: NO 1: YES |
| 1.3.6.1.4.1.4756.20.731.20.1.846 | Columnf2000EASQOSPort3IngressRateRemoteA | read-write | current | f2000EAS Series card QOS Port3 Ingress Rate |
| 1.3.6.1.4.1.4756.20.731.20.1.847 | Columnf2000EASQOSPort3IngressRateUnitRemoteA | read-write | current | f2000EAS Series card QOS Port3 Ingress Rate Unit 0: Kbps 1: Mbps 2: fps 3: kfps |
| 1.3.6.1.4.1.4756.20.731.20.1.848 | Columnf2000EASQOSPort3IngressBurstSizeRemoteA | read-write | current | f2000EAS Series card QOS Port3 Ingress Burst Size |
| 1.3.6.1.4.1.4756.20.731.20.1.849 | Columnf2000EASQOSPort4IngressRemoteA | read-write | current | f2000EAS Series card QOS Port4 Ingress Enabled 0: NO 1: YES |
| 1.3.6.1.4.1.4756.20.731.20.1.850 | Columnf2000EASQOSPort4IngressRateRemoteA | read-write | current | f2000EAS Series card QOS Port4 Ingress Rate |
| 1.3.6.1.4.1.4756.20.731.20.1.851 | Columnf2000EASQOSPort4IngressRateUnitRemoteA | read-write | current | f2000EAS Series card QOS Port4 Ingress Rate Unit 0: Kbps 1: Mbps 2: fps 3: kfps |
| 1.3.6.1.4.1.4756.20.731.20.1.852 | Columnf2000EASQOSPort4IngressBurstSizeRemoteA | read-write | current | f2000EAS Series card QOS Port4 Ingress Burst Size |
| 1.3.6.1.4.1.4756.20.731.20.1.853 | Columnf2000EASQOSPort1EgressRemoteA | read-write | current | f2000EAS Series card QOS Port1 Egress Enabled 0: NO 1: YES |
| 1.3.6.1.4.1.4756.20.731.20.1.854 | Columnf2000EASQOSPort1EgressRateRemoteA | read-write | current | f2000EAS Series card QOS Port1 Egress Rate |
| 1.3.6.1.4.1.4756.20.731.20.1.855 | Columnf2000EASQOSPort1EgressRateUnitRemoteA | read-write | current | f2000EAS Series card QOS Port1 Egress Rate Unit 0: Kbps 1: Mbps |
| 1.3.6.1.4.1.4756.20.731.20.1.856 | Columnf2000EASQOSPort2EgressRemoteA | read-write | current | f2000EAS Series card QOS Port2 Egress Enabled 0: NO 1: YES |
| 1.3.6.1.4.1.4756.20.731.20.1.857 | Columnf2000EASQOSPort2EgressRateRemoteA | read-write | current | f2000EAS Series card QOS Port2 Egress Rate |
| 1.3.6.1.4.1.4756.20.731.20.1.858 | Columnf2000EASQOSPort2EgressRateUnitRemoteA | read-write | current | f2000EAS Series card QOS Port2 Egress Rate Unit 0: Kbps 1: Mbps |
| 1.3.6.1.4.1.4756.20.731.20.1.859 | Columnf2000EASQOSPort3EgressRemoteA | read-write | current | f2000EAS Series card QOS Port3 Egress Enabled 0: NO 1: YES |
| 1.3.6.1.4.1.4756.20.731.20.1.860 | Columnf2000EASQOSPort3EgressRateRemoteA | read-write | current | f2000EAS Series card QOS Port3 Egress Rate |
| 1.3.6.1.4.1.4756.20.731.20.1.861 | Columnf2000EASQOSPort3EgressRateUnitRemoteA | read-write | current | f2000EAS Series card QOS Port3 Egress Rate Unit 0: Kbps 1: Mbps |
| 1.3.6.1.4.1.4756.20.731.20.1.862 | Columnf2000EASQOSPort4EgressRemoteA | read-write | current | f2000EAS Series card QOS Port4 Egress Enabled 0: NO 1: YES |
| 1.3.6.1.4.1.4756.20.731.20.1.863 | Columnf2000EASQOSPort4EgressRateRemoteA | read-write | current | f2000EAS Series card QOS Port4 Egress Rate |
| 1.3.6.1.4.1.4756.20.731.20.1.864 | Columnf2000EASQOSPort4EgressRateUnitRemoteA | read-write | current | f2000EAS Series card QOS Port4 Egress Rate Unit 0: Kbps 1: Mbps |
| 1.3.6.1.4.1.4756.20.731.20.1.865 | Columnf2000EASQOSUnicastRemoteA | read-write | current | f2000EAS Series card QOS Storm Control Configuration- Unicast 0: NO 1: YES |
| 1.3.6.1.4.1.4756.20.731.20.1.866 | Columnf2000EASQOSUnicastRateRemoteA | read-write | current | f2000EAS Series card QOS Storm Control Configuration- Unicast Rate |
| 1.3.6.1.4.1.4756.20.731.20.1.867 | Columnf2000EASQOSUnicastRateUnitRemoteA | read-only | current | f2000EAS Series card QOS Unicast Rate Unit 2: Fps 3: Kfps |
| 1.3.6.1.4.1.4756.20.731.20.1.868 | Columnf2000EASQOSMulticastRemoteA | read-write | current | f2000EAS Series card QOS Storm Control Configuration- Multicast 0: NO 1: YES |
| 1.3.6.1.4.1.4756.20.731.20.1.869 | Columnf2000EASQOSMulticastRateRemoteA | read-write | current | f2000EAS Series card QOS Storm Control Configuration- Multicast Rate |
| 1.3.6.1.4.1.4756.20.731.20.1.870 | Columnf2000EASQOSMulticastRateUnitRemoteA | read-only | current | f2000EAS Series card QOS Multicast Rate Unit 2: Fps 3: Kfps |
| 1.3.6.1.4.1.4756.20.731.20.1.871 | Columnf2000EASQOSBroadcastRemoteA | read-write | current | f2000EAS Series card QOS Storm Control Configuration- Broadcast 0: NO 1: YES |
| 1.3.6.1.4.1.4756.20.731.20.1.872 | Columnf2000EASQOSBroadcastRateRemoteA | read-write | current | f2000EAS Series card QOS Storm Control Configuration- Broadcast Rate |
| 1.3.6.1.4.1.4756.20.731.20.1.873 | Columnf2000EASQOSBroadcastRateUnitRemoteA | read-only | current | f2000EAS Series card QOS Broadcast Rate Unit 2: Fps 3: Kfps |
| 1.3.6.1.4.1.4756.20.731.20.1.874 | Columnf2000EASPort1LLFLogicRemoteA | read-write | current | f2000EAS Series card Port1 link loss forwarding - Logic 0: AND 1: OR |
| 1.3.6.1.4.1.4756.20.731.20.1.875 | Columnf2000EASPort1LLFLogicPort2RemoteA | read-write | current | f2000EAS Series card Port1 link loss forwarding - Link/Rx Loss Port2 0: NO 1: YES |
| 1.3.6.1.4.1.4756.20.731.20.1.876 | Columnf2000EASPort1LLFLogicPort3RemoteA | read-write | current | f2000EAS Series card Port1 link loss forwarding - Link/Rx Loss Port3 0: NO 1: YES |
| 1.3.6.1.4.1.4756.20.731.20.1.877 | Columnf2000EASPort1LLFLogicPort4RemoteA | read-write | current | f2000EAS Series card Port1 link loss forwarding - Link/Rx Loss Port4 0: NO 1: YES |
| 1.3.6.1.4.1.4756.20.731.20.1.878 | Columnf2000EASPort2LLFLogicRemoteA | read-write | current | f2000EAS Series card Port2 link loss forwarding - Logic 0: AND 1: OR |
| 1.3.6.1.4.1.4756.20.731.20.1.879 | Columnf2000EASPort2LLFLogicPort1RemoteA | read-write | current | f2000EAS Series card Port2 link loss forwarding - Link/Rx Loss Port1 0: NO 1: YES |
| 1.3.6.1.4.1.4756.20.731.20.1.880 | Columnf2000EASPort2LLFLogicPort3RemoteA | read-write | current | f2000EAS Series card Port2 link loss forwarding - Link/Rx Loss Port3 0: NO 1: YES |
| 1.3.6.1.4.1.4756.20.731.20.1.881 | Columnf2000EASPort2LLFLogicPort4RemoteA | read-write | current | f2000EAS Series card Port2 link loss forwarding - Link/Rx Loss Port4 0: NO 1: YES |
| 1.3.6.1.4.1.4756.20.731.20.1.882 | Columnf2000EASPort3LLFLogicRemoteA | read-write | current | f2000EAS Series card Port3 link loss forwarding - Logic 0: AND 1: OR |
| 1.3.6.1.4.1.4756.20.731.20.1.883 | Columnf2000EASPort3LLFLogicPort1RemoteA | read-write | current | f2000EAS Series card Port3 link loss forwarding - Link/Rx Loss Port1 0: NO 1: YES |
| 1.3.6.1.4.1.4756.20.731.20.1.884 | Columnf2000EASPort3LLFLogicPort2RemoteA | read-write | current | f2000EAS Series card Port3 link loss forwarding - Link/Rx Loss Port2 0: NO 1: YES |
| 1.3.6.1.4.1.4756.20.731.20.1.885 | Columnf2000EASPort3LLFLogicPort4RemoteA | read-write | current | f2000EAS Series card Port3 link loss forwarding - Link/Rx Loss Port4 0: NO 1: YES |
| 1.3.6.1.4.1.4756.20.731.20.1.886 | Columnf2000EASPort4LLFLogicRemoteA | read-write | current | f2000EAS Series card Port4 link loss forwarding - Logic 0: AND 1: OR |
| 1.3.6.1.4.1.4756.20.731.20.1.887 | Columnf2000EASPort4LLFLogicPort1RemoteA | read-write | current | f2000EAS Series card Port4 link loss forwarding - Link/Rx Loss Port1 0: NO 1: YES |
| 1.3.6.1.4.1.4756.20.731.20.1.888 | Columnf2000EASPort4LLFLogicPort2RemoteA | read-write | current | f2000EAS Series card Port4 link loss forwarding - Link/Rx Loss Port2 0: NO 1: YES |
| 1.3.6.1.4.1.4756.20.731.20.1.889 | Columnf2000EASPort4LLFLogicPort3RemoteA | read-write | current | f2000EAS Series card Port4 link loss forwarding - Link/Rx Loss Port3 0: NO 1: YES |
| 1.3.6.1.4.1.4756.20.731.20.1.890 | Columnf2000EASAddIPRouteRemoteA | read-write | current | f2000EAS Series card IP Routes: Add a new IP Routes : Syntax: [<Interface>] [<network>] [<mask_len>] [<gateway>] [<next_hop_vlan>] Interface : 1~4 |
| 1.3.6.1.4.1.4756.20.731.20.1.891 | Columnf2000EASDeleteIPRouteRemoteA | read-write | current | f2000EAS Series card IP Routes num: Delete a IP Routes num: Syntax: [<Interface>] Interface: 1~4 |
| 1.3.6.1.4.1.4756.20.731.20.1.892 | Columnf2000EASPort1RemotePowerStsRemoteA | read-only | current | f2000EAS Series card Port1 remote Power status 0: None 1: OK 2: Abnormal |
| 1.3.6.1.4.1.4756.20.731.20.1.893 | Columnf2000EASPort2RemotePowerStsRemoteA | read-only | current | f2000EAS Series card Port2 remote Power status 0: None 1: OK 2: Abnormal |
| 1.3.6.1.4.1.4756.20.731.20.1.894 | Columnf2000EASPort3RemotePowerStsRemoteA | read-only | current | f2000EAS Series card Port3 remote Power status 0: None 1: OK 2: Abnormal |
| 1.3.6.1.4.1.4756.20.731.20.1.895 | Columnf2000EASPort4RemotePowerStsRemoteA | read-only | current | f2000EAS Series card Port4 remote Power status 0: None 1: OK 2: Abnormal |
| 1.3.6.1.4.1.4756.20.731.20.1.896 | Columnf2000EASPort1LinkAlarmRemoteA | read-write | current | f2000EAS Series card Port 1 Link alarm: 0: Disable 1: Enable |
| 1.3.6.1.4.1.4756.20.731.20.1.897 | Columnf2000EASPort2LinkAlarmRemoteA | read-write | current | f2000EAS Series card Port 2 Link alarm: 0: Disable 1: Enable |
| 1.3.6.1.4.1.4756.20.731.20.1.898 | Columnf2000EASPort3LinkAlarmRemoteA | read-write | current | f2000EAS Series card Port 3 Link alarm: 0: Disable 1: Enable |
| 1.3.6.1.4.1.4756.20.731.20.1.899 | Columnf2000EASPort4LinkAlarmRemoteA | read-write | current | f2000EAS Series card Port 4 Link alarm: 0: Disable 1: Enable |
| 1.3.6.1.4.1.4756.20.731.20.1.900 | Columnf2000EASAcceptRemoteHWResetRemoteA | read-write | current | f2000EAS Series card Accept Remote H/W Reset: 0: Disable 1: Enable |
| 1.3.6.1.4.1.4756.20.731.20.1.901 | Columnf2000EASRemoteTLPTRemoteA | read-write | current | f2000EAS Series card Remote TLPT: 0: Disable 1: RemoteA 2: RemoteB |
| 1.3.6.1.4.1.4756.20.732 | Nodef2000EASRemoteBCards | |||
| 1.3.6.1.4.1.4756.20.732.20 | Tablef2000EASRemoteBTable | not-accessible | current | A list of RemoteB FRM220A-2000EAS series card entries. |
| 1.3.6.1.4.1.4756.20.732.20.1 | Rowf2000EASRemoteBEntry | not-accessible | current | An entry containing management information applicable to a particular FRM220A-2000EAS series card. |
| 1.3.6.1.4.1.4756.20.732.20.1.1 | Columnf2000EASChassisIndexRemoteB | read-only | current | A unique value for each card. It starts from 0 to 9 contiguously. |
| 1.3.6.1.4.1.4756.20.732.20.1.2 | Columnf2000EASSlotIndexRemoteB | read-only | current | A unique value for each card. It starts from 1 to 20 contiguously. |
| 1.3.6.1.4.1.4756.20.732.20.1.3 | Columnf2000EASCardHWVerRemoteB | read-only | current | f2000EAS Series card hardware version x.xxx |
| 1.3.6.1.4.1.4756.20.732.20.1.4 | Columnf2000EASCardFWVerRemoteB | read-only | current | f2000EAS Series card firmware version x.xxx |
| 1.3.6.1.4.1.4756.20.732.20.1.5 | Columnf2000EASCardCPLDVerRemoteB | read-only | current | f2000EAS Series card CPLD version x.xxx |
| 1.3.6.1.4.1.4756.20.732.20.1.6 | Columnf2000EASCardFPGAVerRemoteB | read-only | current | f2000EAS Series card FPGA version x.xxx |
| 1.3.6.1.4.1.4756.20.732.20.1.7 | Columnf2000EASModelRemoteB | read-only | current | Card Type: 0:2000EAS/4F 1:2000EAS/2F 2:2000EAS/1F |
| 1.3.6.1.4.1.4756.20.732.20.1.8 | Columnf2000EASDNSServerTypeRemoteB | read-write | current | f2000EAS Series card IP Configuration: This setting controls the DNS name resolution done by the switch. The following modes are supported: 0:No DNS server No … |
| 1.3.6.1.4.1.4756.20.732.20.1.9 | Columnf2000EASDNSServerSettingRemoteB | read-write | current | f2000EAS Series card IP Configuration: If iDNSServerType setting '3:Configured',this value must setting IP address format as below: Dotted Decimal Notation ref… |
| 1.3.6.1.4.1.4756.20.732.20.1.10 | Columnf2000EASDNSproxyRemoteB | read-write | current | f2000EAS Series card IP Configuration: When DNS proxy is enabled, system will relay DNS requests to the currently configured DNS server, and reply as a DNS res… |
| 1.3.6.1.4.1.4756.20.732.20.1.11 | Columnf2000EASAddIPV4InterfaceRemoteB | read-write | current | f2000EAS Series card IP Interfaces: Add a new IP VLAN Interface: Syntax: [<Interface>] [<vlan_list>] [<IPV4_Addr>] [<IPV4_MASK>] Interface : 1~4 |
| 1.3.6.1.4.1.4756.20.732.20.1.12 | Columnf2000EASDeleteInterfaceRemoteB | read-write | current | f2000EAS Series card IP Interfaces: Delete a IPv4/v6 VLAN Interface: Syntax: [<Interface>] Interface: 1~4 |
| 1.3.6.1.4.1.4756.20.732.20.1.13 | Columnf2000EASIPInterface1VLANRemoteB | read-only | current | f2000EAS Series card IP Interfaces: The VLAN associated with the IP interface. Only ports in this VLAN will be able to access the IP interface. This field is o… |
| 1.3.6.1.4.1.4756.20.732.20.1.14 | Columnf2000EASIPInterface1DHCPRemoteB | read-write | current | f2000EAS Series card IP Interfaces: DHCP |
| 1.3.6.1.4.1.4756.20.732.20.1.15 | Columnf2000EASIPInterface1FallbackRemoteB | read-write | current | f2000EAS Series card IP Interfaces: Fallback |
| 1.3.6.1.4.1.4756.20.732.20.1.16 | Columnf2000EASIPInterface1IPV4CurrentLeaseRemoteB | read-only | current | f2000EAS Series card IP Interfaces: IPV4 Current Lease Address |
| 1.3.6.1.4.1.4756.20.732.20.1.17 | Columnf2000EASIPInterface1IPV4AddressRemoteB | read-only | current | f2000EAS Series card IP Interfaces: IPV4 Address |
| 1.3.6.1.4.1.4756.20.732.20.1.18 | Columnf2000EASIPInterface1IPV4MASKLenRemoteB | read-only | current | f2000EAS Series card IP Interfaces: IPV4 MASK Length |
| 1.3.6.1.4.1.4756.20.732.20.1.19 | Columnf2000EASIPInterface2VLANRemoteB | read-only | current | f2000EAS Series card IP Interfaces: The VLAN associated with the IP interface. Only ports in this VLAN will be able to access the IP interface. This field is o… |
| 1.3.6.1.4.1.4756.20.732.20.1.20 | Columnf2000EASIPInterface2DHCPRemoteB | read-write | current | f2000EASEDD Series card IP Interfaces: DHCP |
| 1.3.6.1.4.1.4756.20.732.20.1.21 | Columnf2000EASIPInterface2FallbackRemoteB | read-write | current | f2000EASEDD Series card IP Interfaces: Fallback |
| 1.3.6.1.4.1.4756.20.732.20.1.22 | Columnf2000EASIPInterface2IPV4CurrentLeaseRemoteB | read-only | current | f2000EAS Series card IP Interfaces: IPV4 Current Lease Address |
| 1.3.6.1.4.1.4756.20.732.20.1.23 | Columnf2000EASIPInterface2IPV4AddressRemoteB | read-only | current | f2000EAS Series card IP Interfaces: IPV4 Address |
| 1.3.6.1.4.1.4756.20.732.20.1.24 | Columnf2000EASIPInterface2IPV4MASKLenRemoteB | read-only | current | f2000EAS Series card IP Interfaces: IPV4 MASK Length |
| 1.3.6.1.4.1.4756.20.732.20.1.25 | Columnf2000EASIPInterface3VLANRemoteB | read-only | current | f2000EAS Series card IP Interfaces: The VLAN associated with the IP interface. Only ports in this VLAN will be able to access the IP interface. This field is o… |
| 1.3.6.1.4.1.4756.20.732.20.1.26 | Columnf2000EASIPInterface3DHCPRemoteB | read-write | current | f2000EAS Series card IP Interfaces: DHCP |
| 1.3.6.1.4.1.4756.20.732.20.1.27 | Columnf2000EASIPInterface3FallbackRemoteB | read-write | current | f2000EAS Series card IP Interfaces: Fallback |
| 1.3.6.1.4.1.4756.20.732.20.1.28 | Columnf2000EASIPInterface3IPV4CurrentLeaseRemoteB | read-only | current | f2000EAS Series card IP Interfaces: IPV4 Current Lease Address |
| 1.3.6.1.4.1.4756.20.732.20.1.29 | Columnf2000EASIPInterface3IPV4AddressRemoteB | read-only | current | f2000EAS Series card IP Interfaces: IPV4 Address |
| 1.3.6.1.4.1.4756.20.732.20.1.30 | Columnf2000EASIPInterface3IPV4MASKLenRemoteB | read-only | current | f2000EAS Series card IP Interfaces: IPV4 MASK Length |
| 1.3.6.1.4.1.4756.20.732.20.1.31 | Columnf2000EASIPInterface4VLANRemoteB | read-only | current | f2000EAS Series card IP Interfaces: The VLAN associated with the IP interface. Only ports in this VLAN will be able to access the IP interface. This field is o… |
| 1.3.6.1.4.1.4756.20.732.20.1.32 | Columnf2000EASIPInterface4DHCPRemoteB | read-write | current | f2000EAS Series card IP Interfaces: DHCP |
| 1.3.6.1.4.1.4756.20.732.20.1.33 | Columnf2000EASIPInterface4FallbackRemoteB | read-write | current | f2000EAS Series card IP Interfaces: Fallback |
| 1.3.6.1.4.1.4756.20.732.20.1.34 | Columnf2000EASIPInterface4IPV4CurrentLeaseRemoteB | read-only | current | f2000EAS Series card IP Interfaces: IPV4 Current Lease Address |
| 1.3.6.1.4.1.4756.20.732.20.1.35 | Columnf2000EASIPInterface4IPV4AddressRemoteB | read-only | current | f2000EAS Series card IP Interfaces: IPV4 Address |
| 1.3.6.1.4.1.4756.20.732.20.1.36 | Columnf2000EASIPInterface4IPV4MASKLenRemoteB | read-only | current | f2000EAS Series card IP Interfaces: IPV4 MASK Length |
| 1.3.6.1.4.1.4756.20.732.20.1.37 | Columnf2000EASAddIPV6InterfaceRemoteB | read-write | current | f2000EAS Series card IP Interfaces: Add a new IPv6 VLAN Interface: Syntax: [<Interface>] [<vlan_list>] [<IPV4_Addr>] [<IPV4_MASK>] Interface : 1~4 |
| 1.3.6.1.4.1.4756.20.732.20.1.38 | Columnf2000EASIPInterface1IPV6DHCPRemoteB | read-write | current | f2000EAS Series card IP Interfaces: IPV6 DHCP |
| 1.3.6.1.4.1.4756.20.732.20.1.39 | Columnf2000EASIPInterface1IPV6RapidCommitRemoteB | read-write | current | f2000EAS Series card IP Interfaces1: IPV6 RapidCommit |
| 1.3.6.1.4.1.4756.20.732.20.1.40 | Columnf2000EASIPInterface1IPV6CurrentLeaseRemoteB | read-only | current | f2000EAS Series card IP Interfaces: IPV6 Current lease Address |
| 1.3.6.1.4.1.4756.20.732.20.1.41 | Columnf2000EASIPInterface1IPV6AddressRemoteB | read-only | current | f2000EAS Series card IP Interfaces: IPV6 Address |
| 1.3.6.1.4.1.4756.20.732.20.1.42 | Columnf2000EASIPInterface1IPV6MASKLenRemoteB | read-only | current | f2000EAS Series card IP Interfaces: IPV6 MASK Length |
| 1.3.6.1.4.1.4756.20.732.20.1.43 | Columnf2000EASIPInterface2IPV6DHCPRemoteB | read-write | current | f2000EAS Series card IP Interfaces2: IPV6 DHCP |
| 1.3.6.1.4.1.4756.20.732.20.1.44 | Columnf2000EASIPInterface2IPV6RapidCommitRemoteB | read-write | current | f2000EAS Series card IP Interfaces2: IPV6 RapidCommit |
| 1.3.6.1.4.1.4756.20.732.20.1.45 | Columnf2000EASIPInterface2IPV6CurrentLeaseRemoteB | read-only | current | f2000EAS Series card IP Interfaces: IPV6 Current lease Address |
| 1.3.6.1.4.1.4756.20.732.20.1.46 | Columnf2000EASIPInterface2IPV6AddressRemoteB | read-only | current | f2000EAS Series card IP Interfaces: IPV6 Address |
| 1.3.6.1.4.1.4756.20.732.20.1.47 | Columnf2000EASIPInterface2IPV6MASKLenRemoteB | read-only | current | f2000EAS Series card IP Interfaces: IPV6 MASK Length |
| 1.3.6.1.4.1.4756.20.732.20.1.48 | Columnf2000EASIPInterface3IPV6DHCPRemoteB | read-write | current | f2000EAS Series card IP Interfaces2: IPV6 DHCP |
| 1.3.6.1.4.1.4756.20.732.20.1.49 | Columnf2000EASIPInterface3IPV6RapidCommitRemoteB | read-write | current | f2000EAS Series card IP Interfaces3: IPV6 RapidCommit |
| 1.3.6.1.4.1.4756.20.732.20.1.50 | Columnf2000EASIPInterface3IPV6CurrentLeaseRemoteB | read-only | current | f2000EAS Series card IP Interfaces: IPV6 Current lease Address |
| 1.3.6.1.4.1.4756.20.732.20.1.51 | Columnf2000EASIPInterface3IPV6AddressRemoteB | read-only | current | f2000EAS Series card IP Interfaces3: IPV6 Address |
| 1.3.6.1.4.1.4756.20.732.20.1.52 | Columnf2000EASIPInterface3IPV6MASKLenRemoteB | read-only | current | f2000EAS Series card IP Interfaces: IPV6 MASK Length |
| 1.3.6.1.4.1.4756.20.732.20.1.53 | Columnf2000EASIPInterface4IPV6DHCPRemoteB | read-write | current | f2000EAS Series card IP Interfaces4: IPV6 DHCP |
| 1.3.6.1.4.1.4756.20.732.20.1.54 | Columnf2000EASIPInterface4IPV6RapidCommitRemoteB | read-write | current | f2000EAS Series card IP Interfaces4: IPV6 RapidCommit |
| 1.3.6.1.4.1.4756.20.732.20.1.55 | Columnf2000EASIPInterface4IPV6CurrentLeaseRemoteB | read-only | current | f2000EAS Series card IP Interfaces: IPV6 Current lease Address |
| 1.3.6.1.4.1.4756.20.732.20.1.56 | Columnf2000EASIPInterface4IPV6AddressRemoteB | read-only | current | f2000EAS Series card IP Interfaces: IPV6 Address |
| 1.3.6.1.4.1.4756.20.732.20.1.57 | Columnf2000EASIPInterface4IPV6MASKLenRemoteB | read-only | current | f2000EAS Series card IP Interfaces: IPV6 MASK Length |
| 1.3.6.1.4.1.4756.20.732.20.1.58 | Columnf2000EASIPRoutes1NetworkRemoteB | read-only | current | f2000EAS Series card IP Routes: NetWork |
| 1.3.6.1.4.1.4756.20.732.20.1.59 | Columnf2000EASIPRoutes1MASKLenRemoteB | read-only | current | f2000EAS Series card IP Routes: MASK Length |
| 1.3.6.1.4.1.4756.20.732.20.1.60 | Columnf2000EASIPRoutes1GetwayRemoteB | read-only | current | f2000EAS Series card IP Routes: Getway |
| 1.3.6.1.4.1.4756.20.732.20.1.61 | Columnf2000EASIPRoutes1HopVLANRemoteB | read-only | current | f2000EAS Series card IP Routes: The VLAN associated with the IP Routes. Only ports in this VLAN will be able to access the IP Routes. |
| 1.3.6.1.4.1.4756.20.732.20.1.62 | Columnf2000EASIPRoutes2NetworkRemoteB | read-only | current | f2000EAS Series card IP Routes: NetWork |
| 1.3.6.1.4.1.4756.20.732.20.1.63 | Columnf2000EASIPRoutes2MASKLenRemoteB | read-only | current | f2000EAS Series card IP Routes: MASK Length |
| 1.3.6.1.4.1.4756.20.732.20.1.64 | Columnf2000EASIPRoutes2GetwayRemoteB | read-only | current | f2000EAS Series card IP Routes: Getway |
| 1.3.6.1.4.1.4756.20.732.20.1.65 | Columnf2000EASIPRoutes2HopVLANRemoteB | read-only | current | f2000EAS Series card IP Routes: The VLAN associated with the IP Routes. Only ports in this VLAN will be able to access the IP Routes. |
| 1.3.6.1.4.1.4756.20.732.20.1.66 | Columnf2000EASIPRoutes3NetworkRemoteB | read-only | current | f2000EAS Series card IP Routes: NetWork |
| 1.3.6.1.4.1.4756.20.732.20.1.67 | Columnf2000EASIPRoutes3MASKLenRemoteB | read-only | current | f2000EAS Series card IP Routes: MASK Length |
| 1.3.6.1.4.1.4756.20.732.20.1.68 | Columnf2000EASIPRoutes3GetwayRemoteB | read-only | current | f2000EAS Series card IP Routes: Getway |
| 1.3.6.1.4.1.4756.20.732.20.1.69 | Columnf2000EASIPRoutes3HopVLANRemoteB | read-only | current | f2000EAS Series card IP Routes: The VLAN associated with the IP Routes. Only ports in this VLAN will be able to access the IP Routes. |
| 1.3.6.1.4.1.4756.20.732.20.1.70 | Columnf2000EASIPRoutes4NetworkRemoteB | read-only | current | f2000EAS Series card IP Routes: NetWork |
| 1.3.6.1.4.1.4756.20.732.20.1.71 | Columnf2000EASIPRoutes4MASKLenRemoteB | read-only | current | f2000EAS Series card IP Routes: MASK Length |
| 1.3.6.1.4.1.4756.20.732.20.1.72 | Columnf2000EASIPRoutes4GetwayRemoteB | read-only | current | f2000EAS Series card IP Routes: Getway |
| 1.3.6.1.4.1.4756.20.732.20.1.73 | Columnf2000EASIPRoutes4HopVLANRemoteB | read-only | current | f2000EAS Series card IP Routes: The VLAN associated with the IP Routes. Only ports in this VLAN will be able to access the IP Routes. |
| 1.3.6.1.4.1.4756.20.732.20.1.74 | Columnf2000EASPort1LinkstsRemoteB | read-only | current | f2000EAS Series card Port1 link status: 0:Link down 1:Link up |
| 1.3.6.1.4.1.4756.20.732.20.1.75 | Columnf2000EASPort1SpeedstsRemoteB | read-only | current | f2000EAS Series card Port1 speed status |
| 1.3.6.1.4.1.4756.20.732.20.1.76 | Columnf2000EASPort1DuplexstsRemoteB | read-only | current | f2000EAS Series card Port1 duplex status 0: Half 1: Full |
| 1.3.6.1.4.1.4756.20.732.20.1.77 | Columnf2000EASPort1RxPausestsRemoteB | read-only | current | f2000EAS Series card Port1 rx pause status 0: No 1: Yes |
| 1.3.6.1.4.1.4756.20.732.20.1.78 | Columnf2000EASPort1TxPausestsRemoteB | read-only | current | f2000EAS Series card Port1 tx pause status 0: No 1: Yes |
| 1.3.6.1.4.1.4756.20.732.20.1.79 | Columnf2000EASPort2LinkstsRemoteB | read-only | current | f2000EAS Series card Port2 link status: 0:Link down 1:Link up |
| 1.3.6.1.4.1.4756.20.732.20.1.80 | Columnf2000EASPort2SpeedstsRemoteB | read-only | current | f2000EAS Series card Port2 speed status |
| 1.3.6.1.4.1.4756.20.732.20.1.81 | Columnf2000EASPort2DuplexstsRemoteB | read-only | current | f2000EAS Series card Port2 duplex status 0: Half 1: Full |
| 1.3.6.1.4.1.4756.20.732.20.1.82 | Columnf2000EASPort2RxPausestsRemoteB | read-only | current | f2000EAS Series card Port2 rx pause status 0: No 1: Yes |
| 1.3.6.1.4.1.4756.20.732.20.1.83 | Columnf2000EASPort2TxPausestsRemoteB | read-only | current | f2000EAS Series card Port2 tx pause status 0: No 1: Yes |
| 1.3.6.1.4.1.4756.20.732.20.1.84 | Columnf2000EASPort3LinkstsRemoteB | read-only | current | f2000EAS Series card Port3 link status: 0:Link down 1:Link up |
| 1.3.6.1.4.1.4756.20.732.20.1.85 | Columnf2000EASPort3SpeedstsRemoteB | read-only | current | f2000EAS Series card Port3 speed status |
| 1.3.6.1.4.1.4756.20.732.20.1.86 | Columnf2000EASPort3DuplexstsRemoteB | read-only | current | f2000EAS Series card Port3 duplex status 0: Half 1: Full |
| 1.3.6.1.4.1.4756.20.732.20.1.87 | Columnf2000EASPort3RxPausestsRemoteB | read-only | current | f2000EAS Series card Port3 rx pause status 0: No 1: Yes |
| 1.3.6.1.4.1.4756.20.732.20.1.88 | Columnf2000EASPort3TxPausestsRemoteB | read-only | current | f2000EAS Series card Port3 tx pause status 0: No 1: Yes |
| 1.3.6.1.4.1.4756.20.732.20.1.89 | Columnf2000EASPort4LinkstsRemoteB | read-only | current | f2000EAS Series card Port4 link status: 0:Link down 1:Link up |
| 1.3.6.1.4.1.4756.20.732.20.1.90 | Columnf2000EASPort4SpeedstsRemoteB | read-only | current | f2000EAS Series card Port4 speed status |
| 1.3.6.1.4.1.4756.20.732.20.1.91 | Columnf2000EASPort4DuplexstsRemoteB | read-only | current | f2000EAS Series card Port4 duplex status 0: Half 1: Full |
| 1.3.6.1.4.1.4756.20.732.20.1.92 | Columnf2000EASPort4RxPausestsRemoteB | read-only | current | f2000EAS Series card Port4 rx pause status 0: No 1: Yes |
| 1.3.6.1.4.1.4756.20.732.20.1.93 | Columnf2000EASPort4TxPausestsRemoteB | read-only | current | f2000EAS Series card Port4 tx pause status 0: No 1: Yes |
| 1.3.6.1.4.1.4756.20.732.20.1.94 | Columnf2000EASPort1SpeedConfRemoteB | read-write | current | f2000EAS Series card Port1 speed config 0: disable 1: auto 2: 100M FDX 3: 1G FDX |
| 1.3.6.1.4.1.4756.20.732.20.1.95 | Columnf2000EASPort1flowConrolRemoteB | read-write | current | f2000EAS Series card Port1 flow control config 0: no 1: yes |
| 1.3.6.1.4.1.4756.20.732.20.1.96 | Columnf2000EASPort1MaxFrameRemoteB | read-write | current | f2000EAS Series card Port1 max frame config |
| 1.3.6.1.4.1.4756.20.732.20.1.97 | Columnf2000EASPort1ALSRemoteB | read-write | current | f2000EAS Series card Port1 auto laser shutdown: 0: Disable 1: Enable |
| 1.3.6.1.4.1.4756.20.732.20.1.98 | Columnf2000EASPort1FrameLengthCheckRemoteB | read-write | current | f2000EAS Series card Port1 Frame Length Check config 0: no 1: yes |
| 1.3.6.1.4.1.4756.20.732.20.1.99 | Columnf2000EASPort2SpeedConfRemoteB | read-write | current | f2000EAS Series card Port2 speed config 0: disable 1: auto 2: 100M FDX 3: 1G FDX |
| 1.3.6.1.4.1.4756.20.732.20.1.100 | Columnf2000EASPort2flowConrolRemoteB | read-write | current | f2000EAS Series card Port2 flow control config 0: no 1: yes |
| 1.3.6.1.4.1.4756.20.732.20.1.101 | Columnf2000EASPort2MaxFrameRemoteB | read-write | current | f2000EAS Series card Port2 max frame config |
| 1.3.6.1.4.1.4756.20.732.20.1.102 | Columnf2000EASPort2ALSRemoteB | read-write | current | f2000EAS Series card Port2 auto laser shutdown: 0: Disable 1: Enable |
| 1.3.6.1.4.1.4756.20.732.20.1.103 | Columnf2000EASPort2FrameLengthCheckRemoteB | read-write | current | f2000EAS Series card Port2 Frame Length Check config 0: no 1: yes |
| 1.3.6.1.4.1.4756.20.732.20.1.104 | Columnf2000EASPort3SpeedConfRemoteB | read-write | current | f2000EAS Series card Port3 speed config 0: disable 1: auto 2: 10M HDX 3: 10M FDX 4: 100M HDX 5: 100M FDX 6: 1G FDX |
| 1.3.6.1.4.1.4756.20.732.20.1.105 | Columnf2000EASPort3flowConrolRemoteB | read-write | current | f2000EAS Series card Port3 flow control config 0: no 1: yes |
| 1.3.6.1.4.1.4756.20.732.20.1.106 | Columnf2000EASPort3MaxFrameRemoteB | read-write | current | f2000EAS Series card Port3 max frame config |
| 1.3.6.1.4.1.4756.20.732.20.1.107 | Columnf2000EASPort3CollisionModeRemoteB | read-write | current | f2000EAS Series card Port3 collision mode config. 0: Discard 1: Restart |
| 1.3.6.1.4.1.4756.20.732.20.1.108 | Columnf2000EASPort3ALSRemoteB | read-write | current | f2000EAS Series card Port3 auto laser shutdown 0: Disable 1: Enable |
| 1.3.6.1.4.1.4756.20.732.20.1.109 | Columnf2000EASPort3FrameLengthCheckRemoteB | read-write | current | f2000EAS Series card Port3 Frame Length Check config 0: no 1: yes |
| 1.3.6.1.4.1.4756.20.732.20.1.110 | Columnf2000EASPort4SpeedConfRemoteB | read-write | current | f2000EAS Series card Port4 speed config 0: disable 1: auto 2: 10M HDX 3: 10M FDX 4: 100M HDX 5: 100M FDX 6: 1G FDX |
| 1.3.6.1.4.1.4756.20.732.20.1.111 | Columnf2000EASPort4flowConrolRemoteB | read-write | current | f2000EAS Series card Port4 flow control config 0: no 1: yes |
| 1.3.6.1.4.1.4756.20.732.20.1.112 | Columnf2000EASPort4MaxFrameRemoteB | read-write | current | f2000EAS Series card Port4 max frame config |
| 1.3.6.1.4.1.4756.20.732.20.1.113 | Columnf2000EASPort4CollisionModeRemoteB | read-write | current | f2000EAS Series card Port4 collision mode config 0: Discard 1: Restart |
| 1.3.6.1.4.1.4756.20.732.20.1.114 | Columnf2000EASPort4ALSRemoteB | read-write | current | f2000EAS Series card Port4 auto laser shutdown 0: Disable 1: Enable |
| 1.3.6.1.4.1.4756.20.732.20.1.115 | Columnf2000EASPort4FrameLengthCheckRemoteB | read-write | current | f2000EAS Series card Port4 Frame Length Check config 0: no 1: yes |
| 1.3.6.1.4.1.4756.20.732.20.1.116 | Columnf2000EASPort1AdvDuplexHdxRemoteB | read-write | current | f2000EAS Series card Port1 Adv Dpulex Hdx 0: OFF 1: ON |
| 1.3.6.1.4.1.4756.20.732.20.1.117 | Columnf2000EASPort1AdvDuplexFdxRemoteB | read-write | current | f2000EAS Series card Port1 Adv Dpulex Fdx 0: OFF 1: ON |
| 1.3.6.1.4.1.4756.20.732.20.1.118 | Columnf2000EASPort1AdvSpeed10MRemoteB | read-write | current | f2000EAS Series card Port1 Adv Speed 10M 0: OFF 1: ON |
| 1.3.6.1.4.1.4756.20.732.20.1.119 | Columnf2000EASPort1AdvSpeed100MRemoteB | read-write | current | f2000EAS Series card Port1 Adv Speed 100M 0: OFF 1: ON |
| 1.3.6.1.4.1.4756.20.732.20.1.120 | Columnf2000EASPort1AdvSpeed1GRemoteB | read-write | current | f2000EAS Series card Port1 Adv Speed 1G 0: OFF 1: ON |
| 1.3.6.1.4.1.4756.20.732.20.1.121 | Columnf2000EASPort2AdvDuplexHdxRemoteB | read-write | current | f2000EAS Series card Port2 Adv Dpulex Hdx 0: OFF 1: ON |
| 1.3.6.1.4.1.4756.20.732.20.1.122 | Columnf2000EASPort2AdvDuplexFdxRemoteB | read-write | current | f2000EAS Series card Port2 Adv Dpulex Fdx 0: OFF 1: ON |
| 1.3.6.1.4.1.4756.20.732.20.1.123 | Columnf2000EASPort2AdvSpeed10MRemoteB | read-write | current | f2000EAS Series card Port2 Adv Speed 10M 0: OFF 1: ON |
| 1.3.6.1.4.1.4756.20.732.20.1.124 | Columnf2000EASPort2AdvSpeed100MRemoteB | read-write | current | f2000EAS Series card Port2 Adv Speed 100M 0: OFF 1: ON |
| 1.3.6.1.4.1.4756.20.732.20.1.125 | Columnf2000EASPort2AdvSpeed1GRemoteB | read-write | current | f2000EAS Series card Port2 Adv Speed 1G 0: OFF 1: ON |
| 1.3.6.1.4.1.4756.20.732.20.1.126 | Columnf2000EASPort3AdvDuplexHdxRemoteB | read-write | current | f2000EAS Series card Port3 Adv Dpulex Hdx 0: OFF 1: ON |
| 1.3.6.1.4.1.4756.20.732.20.1.127 | Columnf2000EASPort3AdvDuplexFdxRemoteB | read-write | current | f2000EAS Series card Port3 Adv Dpulex Fdx 0: OFF 1: ON |
| 1.3.6.1.4.1.4756.20.732.20.1.128 | Columnf2000EASPort3AdvSpeed10MRemoteB | read-write | current | f2000EAS Series card Port3 Adv Speed 10M 0: OFF 1: ON |
| 1.3.6.1.4.1.4756.20.732.20.1.129 | Columnf2000EASPort3AdvSpeed100MRemoteB | read-write | current | f2000EAS Series card Port3 Adv Speed 100M 0: OFF 1: ON |
| 1.3.6.1.4.1.4756.20.732.20.1.130 | Columnf2000EASPort3AdvSpeed1GRemoteB | read-write | current | f2000EAS Series card Port3 Adv Speed 1G 0: OFF 1: ON |
| 1.3.6.1.4.1.4756.20.732.20.1.131 | Columnf2000EASPort4AdvDuplexHdxRemoteB | read-write | current | f2000EAS Series card Port4 Adv Dpulex Hdx 0: OFF 1: ON |
| 1.3.6.1.4.1.4756.20.732.20.1.132 | Columnf2000EASPort4AdvDuplexFdxRemoteB | read-write | current | f2000EAS Series card Port4 Adv Dpulex Fdx 0: OFF 1: ON |
| 1.3.6.1.4.1.4756.20.732.20.1.133 | Columnf2000EASPort4AdvSpeed10MRemoteB | read-write | current | f2000EAS Series card Port4 Adv Speed 10M 0: OFF 1: ON |
| 1.3.6.1.4.1.4756.20.732.20.1.134 | Columnf2000EASPort4AdvSpeed100MRemoteB | read-write | current | f2000EAS Series card Port4 Adv Speed 100M 0: OFF 1: ON |
| 1.3.6.1.4.1.4756.20.732.20.1.135 | Columnf2000EASPort4AdvSpeed1GRemoteB | read-write | current | f2000EAS Series card Port4 Adv Speed 1G 0: OFF 1: ON |
| 1.3.6.1.4.1.4756.20.732.20.1.136 | Columnf2000EASPortResetRemoteB | read-write | current | f2000EAS Series card port reset 0: OFF 1: Action |
| 1.3.6.1.4.1.4756.20.732.20.1.137 | Columnf2000EASSetDefaultRemoteB | read-write | current | f2000EAS Series card set to default config 0: OFF 1: Action |
| 1.3.6.1.4.1.4756.20.732.20.1.138 | Columnf2000EASPort1PacketsRxRemoteB | read-only | current | f2000EAS Series card port1 traffic overview:: Packets Rx |
| 1.3.6.1.4.1.4756.20.732.20.1.139 | Columnf2000EASPort1PacketsTxRemoteB | read-only | current | f2000EAS Series card port1 traffic overview:: Packets Tx |
| 1.3.6.1.4.1.4756.20.732.20.1.140 | Columnf2000EASPort1BytesRxRemoteB | read-only | current | f2000EAS Series card port1 traffic overview:: Bytes Rx |
| 1.3.6.1.4.1.4756.20.732.20.1.141 | Columnf2000EASPort1BytesTxRemoteB | read-only | current | f2000EAS Series card port1 traffic overview:: Bytes Tx |
| 1.3.6.1.4.1.4756.20.732.20.1.142 | Columnf2000EASPort1ErrorsRxRemoteB | read-only | current | f2000EAS Series card port1 traffic overview:: Errors Rx |
| 1.3.6.1.4.1.4756.20.732.20.1.143 | Columnf2000EASPort1ErrorsTxRemoteB | read-only | current | f2000EAS Series card port1 traffic overview:: Errors Tx |
| 1.3.6.1.4.1.4756.20.732.20.1.144 | Columnf2000EASPort1DropsRxRemoteB | read-only | current | f2000EAS Series card port1 traffic overview:: Drops Rx |
| 1.3.6.1.4.1.4756.20.732.20.1.145 | Columnf2000EASPort1DropsTxRemoteB | read-only | current | f2000EAS Series card port1 traffic overview:: Drops Tx |
| 1.3.6.1.4.1.4756.20.732.20.1.146 | Columnf2000EASPort1FilteredRxRemoteB | read-only | current | f2000EAS Series card port1 traffic overview:: Filtered Rx |
| 1.3.6.1.4.1.4756.20.732.20.1.147 | Columnf2000EASPort2PacketsRxRemoteB | read-only | current | f2000EAS Series card port2 traffic overview:: Packets Rx |
| 1.3.6.1.4.1.4756.20.732.20.1.148 | Columnf2000EASPort2PacketsTxRemoteB | read-only | current | f2000EAS Series card port2 traffic overview:: Packets Tx |
| 1.3.6.1.4.1.4756.20.732.20.1.149 | Columnf2000EASPort2BytesRxRemoteB | read-only | current | f2000EAS Series card port2 traffic overview:: Bytes Rx |
| 1.3.6.1.4.1.4756.20.732.20.1.150 | Columnf2000EASPort2BytesTxRemoteB | read-only | current | f2000EAS Series card port2 traffic overview:: Bytes Tx |
| 1.3.6.1.4.1.4756.20.732.20.1.151 | Columnf2000EASPort2ErrorsRxRemoteB | read-only | current | f2000EAS Series card port2 traffic overview:: Errors Rx |
| 1.3.6.1.4.1.4756.20.732.20.1.152 | Columnf2000EASPort2ErrorsTxRemoteB | read-only | current | f2000EAS Series card port2 traffic overview:: Errors Tx |
| 1.3.6.1.4.1.4756.20.732.20.1.153 | Columnf2000EASPort2DropsRxRemoteB | read-only | current | f2000EAS Series card port2 traffic overview:: Drops Rx |
| 1.3.6.1.4.1.4756.20.732.20.1.154 | Columnf2000EASPort2DropsTxRemoteB | read-only | current | f2000EAS Series card port2 traffic overview:: Drops Tx |
| 1.3.6.1.4.1.4756.20.732.20.1.155 | Columnf2000EASPort2FilteredRxRemoteB | read-only | current | f2000EAS Series card port2 traffic overview:: Filtered Rx |
| 1.3.6.1.4.1.4756.20.732.20.1.156 | Columnf2000EASPort3PacketsRxRemoteB | read-only | current | f2000EAS Series card port3 traffic overview:: Packets Rx |
| 1.3.6.1.4.1.4756.20.732.20.1.157 | Columnf2000EASPort3PacketsTxRemoteB | read-only | current | f2000EAS Series card port3 traffic overview:: Packets Tx |
| 1.3.6.1.4.1.4756.20.732.20.1.158 | Columnf2000EASPort3BytesRxRemoteB | read-only | current | f2000EAS Series card port3 traffic overview:: Bytes Rx |
| 1.3.6.1.4.1.4756.20.732.20.1.159 | Columnf2000EASPort3BytesTxRemoteB | read-only | current | f2000EAS Series card port3 traffic overview:: Bytes Tx |
| 1.3.6.1.4.1.4756.20.732.20.1.160 | Columnf2000EASPort3ErrorsRxRemoteB | read-only | current | f2000EAS Series card port3 traffic overview:: Errors Rx |
| 1.3.6.1.4.1.4756.20.732.20.1.161 | Columnf2000EASPort3ErrorsTxRemoteB | read-only | current | f2000EAS Series card port3 traffic overview:: Errors Tx |
| 1.3.6.1.4.1.4756.20.732.20.1.162 | Columnf2000EASPort3DropsRxRemoteB | read-only | current | f2000EAS Series card port3 traffic overview:: Drops Rx |
| 1.3.6.1.4.1.4756.20.732.20.1.163 | Columnf2000EASPort3DropsTxRemoteB | read-only | current | f2000EAS Series card port3 traffic overview:: Drops Tx |
| 1.3.6.1.4.1.4756.20.732.20.1.164 | Columnf2000EASPort3FilteredRxRemoteB | read-only | current | f2000EAS Series card port3 traffic overview:: Filtered Rx |
| 1.3.6.1.4.1.4756.20.732.20.1.165 | Columnf2000EASPort4PacketsRxRemoteB | read-only | current | f2000EAS Series card port4 traffic overview:: Packets Rx |
| 1.3.6.1.4.1.4756.20.732.20.1.166 | Columnf2000EASPort4PacketsTxRemoteB | read-only | current | f2000EAS Series card port4 traffic overview:: Packets Tx |
| 1.3.6.1.4.1.4756.20.732.20.1.167 | Columnf2000EASPort4BytesRxRemoteB | read-only | current | f2000EAS Series card port4 traffic overview:: Bytes Rx |
| 1.3.6.1.4.1.4756.20.732.20.1.168 | Columnf2000EASPort4BytesTxRemoteB | read-only | current | f2000EAS Series card port4 traffic overview:: Bytes Tx |
| 1.3.6.1.4.1.4756.20.732.20.1.169 | Columnf2000EASPort4ErrorsRxRemoteB | read-only | current | f2000EAS Series card port4 traffic overview:: Errors Rx |
| 1.3.6.1.4.1.4756.20.732.20.1.170 | Columnf2000EASPort4ErrorsTxRemoteB | read-only | current | f2000EAS Series card port4 traffic overview:: Errors Tx |
| 1.3.6.1.4.1.4756.20.732.20.1.171 | Columnf2000EASPort4DropsRxRemoteB | read-only | current | f2000EAS Series card port4 traffic overview:: Drops Rx |
| 1.3.6.1.4.1.4756.20.732.20.1.172 | Columnf2000EASPort4DropsTxRemoteB | read-only | current | f2000EAS Series card port4 traffic overview:: Drops Tx |
| 1.3.6.1.4.1.4756.20.732.20.1.173 | Columnf2000EASPort4FilteredRxRemoteB | read-only | current | f2000EAS Series card port4 traffic overview:: Filtered Rx |
| 1.3.6.1.4.1.4756.20.732.20.1.174 | Columnf2000EASDeviceActiveRemoteB | read-only | current | f2000EAS Series card device active 0: Disable 1: Enable |
| 1.3.6.1.4.1.4756.20.732.20.1.175 | Columnf2000EASFx1DDRemoteB | read-only | current | f2000EAS Series card fiber1 port Digital Diagnostic function: 0:No 1:Yes |
| 1.3.6.1.4.1.4756.20.732.20.1.176 | Columnf2000EASFx1DDVendorRemoteB | read-only | current | f2000EAS Series card fiber1 port D/D information: Vendor name |
| 1.3.6.1.4.1.4756.20.732.20.1.177 | Columnf2000EASFx1DDPartNoRemoteB | read-only | current | f2000EAS Series card fiber1 port D/D information: Vendor part number |
| 1.3.6.1.4.1.4756.20.732.20.1.178 | Columnf2000EASFx1DDFiberTypeRemoteB | read-only | current | f2000EAS Series card fiber1 port D/D information: Fiber Type |
| 1.3.6.1.4.1.4756.20.732.20.1.179 | Columnf2000EASFx1DDWaveLenRemoteB | read-only | current | f2000EAS Series card fiber1 port D/D information: Wave length |
| 1.3.6.1.4.1.4756.20.732.20.1.180 | Columnf2000EASFx1DDWaveLen2RemoteB | read-only | current | f2000EAS Series card fiber1 port D/D information: Wave length 2 |
| 1.3.6.1.4.1.4756.20.732.20.1.181 | Columnf2000EASFx1DDLinkLenRemoteB | read-only | current | f2000EAS Series card fiber1 port D/D information: Link length |
| 1.3.6.1.4.1.4756.20.732.20.1.182 | Columnf2000EASFx1DDLenUnitRemoteB | read-only | current | f2000EAS Series card fiber1 port D/D information: Length Unit |
| 1.3.6.1.4.1.4756.20.732.20.1.183 | Columnf2000EASFx1DDStatusRemoteB | read-only | current | f2000EAS Series card fiber1 port D/D information: Status Support |
| 1.3.6.1.4.1.4756.20.732.20.1.184 | Columnf2000EASFx1DDRxSensRemoteB | read-only | current | f2000EAS Series card fiber1 port D/D information: Rx Sensitivity |
| 1.3.6.1.4.1.4756.20.732.20.1.185 | Columnf2000EASFx1DDTxPWRRemoteB | read-only | current | f2000EAS Series card fiber1 port D/D information: Tx power |
| 1.3.6.1.4.1.4756.20.732.20.1.186 | Columnf2000EASFx1DDRxPWRRemoteB | read-only | current | f2000EAS Series card fiber1 port D/D information: Rx power |
| 1.3.6.1.4.1.4756.20.732.20.1.187 | Columnf2000EASFx1DDTempRemoteB | read-only | current | f2000EAS Series card fiber1 port D/D information: Temperature in degree C |
| 1.3.6.1.4.1.4756.20.732.20.1.188 | Columnf2000EASFx1DDPWRMarginRemoteB | read-only | current | f2000EAS Series card fiber1 port D/D information: Power margin |
| 1.3.6.1.4.1.4756.20.732.20.1.189 | Columnf2000EASFx1DDPWRLossRemoteB | read-only | current | f2000EAS Series card fiber1 port D/D information: Power loss |
| 1.3.6.1.4.1.4756.20.732.20.1.190 | Columnf2000EASFx2DDRemoteB | read-only | current | f2000EAS Series card fiber2 Digital Diagnostic function: 0:NO 1:Yes |
| 1.3.6.1.4.1.4756.20.732.20.1.191 | Columnf2000EASFx2DDVendorRemoteB | read-only | current | f2000EAS Series card fiber2 D/D information: Vendor name |
| 1.3.6.1.4.1.4756.20.732.20.1.192 | Columnf2000EASFx2DDPartNoRemoteB | read-only | current | f2000EAS Series card fiber2 D/D information: Vendor part number |
| 1.3.6.1.4.1.4756.20.732.20.1.193 | Columnf2000EASFx2DDFiberTypeRemoteB | read-only | current | f2000EAS Series card fiber2 D/D information: Fiber Type |
| 1.3.6.1.4.1.4756.20.732.20.1.194 | Columnf2000EASFx2DDWaveLenRemoteB | read-only | current | f2000EAS Series card fiber2 D/D information: Wave length 1 |
| 1.3.6.1.4.1.4756.20.732.20.1.195 | Columnf2000EASFx2DDWaveLen2RemoteB | read-only | current | f2000EAS Series card fiber2 D/D information: Wave length 2 |
| 1.3.6.1.4.1.4756.20.732.20.1.196 | Columnf2000EASFx2DDLinkLenRemoteB | read-only | current | f2000EAS Series card fiber2 D/D information: Link length |
| 1.3.6.1.4.1.4756.20.732.20.1.197 | Columnf2000EASFx2DDLenUnitRemoteB | read-only | current | f2000EAS Series card fiber2 D/D information: Length Unit |
| 1.3.6.1.4.1.4756.20.732.20.1.198 | Columnf2000EASFx2DDStatusRemoteB | read-only | current | f2000EAS Series card fiber2 D/D information: Status Support |
| 1.3.6.1.4.1.4756.20.732.20.1.199 | Columnf2000EASFx2DDRxSensRemoteB | read-only | current | f2000EAS Series card fiber2 D/D information: Rx Sensitivity |
| 1.3.6.1.4.1.4756.20.732.20.1.200 | Columnf2000EASFx2DDTxPWRRemoteB | read-only | current | f2000EAS Series card fiber2 D/D information: Tx power |
| 1.3.6.1.4.1.4756.20.732.20.1.201 | Columnf2000EASFx2DDRxPWRRemoteB | read-only | current | f2000EAS Series card fiber2 D/D information: Rx power |
| 1.3.6.1.4.1.4756.20.732.20.1.202 | Columnf2000EASFx2DDTempRemoteB | read-only | current | f2000EAS Series card fiber2 D/D information: Temperature in degree C |
| 1.3.6.1.4.1.4756.20.732.20.1.203 | Columnf2000EASFx2DDPWRMarginRemoteB | read-only | current | f2000EAS Series card fiber2 D/D information: Power margin |
| 1.3.6.1.4.1.4756.20.732.20.1.204 | Columnf2000EASFx2DDPWRLossRemoteB | read-only | current | f2000EAS Series card fiber2 D/D information: Power loss |
| 1.3.6.1.4.1.4756.20.732.20.1.205 | Columnf2000EASFx3DDRemoteB | read-only | current | f2000EAS Series card fiber3 Digital Diagnostic function: 0:NO 1:Yes |
| 1.3.6.1.4.1.4756.20.732.20.1.206 | Columnf2000EASFx3DDVendorRemoteB | read-only | current | f2000EAS Series card fiber3 D/D information: Vendor name |
| 1.3.6.1.4.1.4756.20.732.20.1.207 | Columnf2000EASFx3DDPartNoRemoteB | read-only | current | f2000EAS Series card fiber32 D/D information: Vendor part number |
| 1.3.6.1.4.1.4756.20.732.20.1.208 | Columnf2000EASFx3DDFiberTypeRemoteB | read-only | current | f2000EAS Series card fiber3 D/D information: Fiber Type |
| 1.3.6.1.4.1.4756.20.732.20.1.209 | Columnf2000EASFx3DDWaveLenRemoteB | read-only | current | f2000EAS Series card fiber3 D/D information: Wave length 1 |
| 1.3.6.1.4.1.4756.20.732.20.1.210 | Columnf2000EASFx3DDWaveLen2RemoteB | read-only | current | f2000EAS Series card fiber3 D/D information: Wave length 2 |
| 1.3.6.1.4.1.4756.20.732.20.1.211 | Columnf2000EASFx3DDLinkLenRemoteB | read-only | current | f2000EAS Series card fiber3 D/D information: Link length |
| 1.3.6.1.4.1.4756.20.732.20.1.212 | Columnf2000EASFx3DDLenUnitRemoteB | read-only | current | f2000EAS Series card fiber3 D/D information: Length Unit |
| 1.3.6.1.4.1.4756.20.732.20.1.213 | Columnf2000EASFx3DDStatusRemoteB | read-only | current | f2000EAS Series card fiber3 D/D information: Status Support |
| 1.3.6.1.4.1.4756.20.732.20.1.214 | Columnf2000EASFx3DDRxSensRemoteB | read-only | current | f2000EAS Series card fiber3 D/D information: Rx Sensitivity |
| 1.3.6.1.4.1.4756.20.732.20.1.215 | Columnf2000EASFx3DDTxPWRRemoteB | read-only | current | f2000EAS Series card fiber3 D/D information: Tx power |
| 1.3.6.1.4.1.4756.20.732.20.1.216 | Columnf2000EASFx3DDRxPWRRemoteB | read-only | current | f2000EAS Series card fiber3 D/D information: Rx power |
| 1.3.6.1.4.1.4756.20.732.20.1.217 | Columnf2000EASFx3DDTempRemoteB | read-only | current | f2000EAS Series card fiber3 D/D information: Temperature in degree C |
| 1.3.6.1.4.1.4756.20.732.20.1.218 | Columnf2000EASFx3DDPWRMarginRemoteB | read-only | current | f2000EAS Series card fiber3 D/D information: Power margin |
| 1.3.6.1.4.1.4756.20.732.20.1.219 | Columnf2000EASFx3DDPWRLossRemoteB | read-only | current | f2000EAS Series card fiber3 D/D information: Power loss |
| 1.3.6.1.4.1.4756.20.732.20.1.220 | Columnf2000EASFx4DDRemoteB | read-only | current | f2000EAS Series card fiber4 Digital Diagnostic function: 0:NO 1:Yes |
| 1.3.6.1.4.1.4756.20.732.20.1.221 | Columnf2000EASFx4DDVendorRemoteB | read-only | current | f2000EAS Series card fiber4 D/D information: Vendor name |
| 1.3.6.1.4.1.4756.20.732.20.1.222 | Columnf2000EASFx4DDPartNoRemoteB | read-only | current | f2000EAS Series card fiber4 D/D information: Vendor part number |
| 1.3.6.1.4.1.4756.20.732.20.1.223 | Columnf2000EASFx4DDFiberTypeRemoteB | read-only | current | f2000EAS Series card fiber4 D/D information: Fiber Type |
| 1.3.6.1.4.1.4756.20.732.20.1.224 | Columnf2000EASFx4DDWaveLenRemoteB | read-only | current | f2000EAS Series card fiber4 D/D information: Wave length 1 |
| 1.3.6.1.4.1.4756.20.732.20.1.225 | Columnf2000EASFx4DDWaveLen2RemoteB | read-only | current | f2000EAS Series card fiber4 D/D information: Wave length 2 |
| 1.3.6.1.4.1.4756.20.732.20.1.226 | Columnf2000EASFx4DDLinkLenRemoteB | read-only | current | f2000EAS Series card fiber4 D/D information: Link length |
| 1.3.6.1.4.1.4756.20.732.20.1.227 | Columnf2000EASFx4DDLenUnitRemoteB | read-only | current | f2000EAS Series card fiber4 D/D information: Length Unit |
| 1.3.6.1.4.1.4756.20.732.20.1.228 | Columnf2000EASFx4DDStatusRemoteB | read-only | current | f2000EAS Series card fiber4 D/D information: Status Support |
| 1.3.6.1.4.1.4756.20.732.20.1.229 | Columnf2000EASFx4DDRxSensRemoteB | read-only | current | f2000EAS Series card fiber4 D/D information: Rx Sensitivity |
| 1.3.6.1.4.1.4756.20.732.20.1.230 | Columnf2000EASFx4DDTxPWRRemoteB | read-only | current | f2000EAS Series card fiber4 D/D information: Tx power |
| 1.3.6.1.4.1.4756.20.732.20.1.231 | Columnf2000EASFx4DDRxPWRRemoteB | read-only | current | f2000EAS Series card fiber4 D/D information: Rx power |
| 1.3.6.1.4.1.4756.20.732.20.1.232 | Columnf2000EASFx4DDTempRemoteB | read-only | current | f2000EAS Series card fiber4 D/D information: Temperature in degree C |
| 1.3.6.1.4.1.4756.20.732.20.1.233 | Columnf2000EASFx4DDPWRMarginRemoteB | read-only | current | f2000EAS Series card fiber4 D/D information: Power margin |
| 1.3.6.1.4.1.4756.20.732.20.1.234 | Columnf2000EASFx4DDPWRLossRemoteB | read-only | current | f2000EAS Series card fiber4 D/D information: Power loss |
| 1.3.6.1.4.1.4756.20.732.20.1.235 | Columnf2000EASTestRemoteB | read-only | current | f2000EAS Series card test led sts: 0: Off 1: On |
| 1.3.6.1.4.1.4756.20.732.20.1.236 | Columnf2000EASClearPortCounterRemoteB | read-write | current | f2000EAS Series card clear port counter: 0: Off 1: Action |
| 1.3.6.1.4.1.4756.20.732.20.1.237 | Columnf2000EASAggrSourceMACAddrRemoteB | read-write | current | f2000EAS Series card Aggregation Mode Configuration: Source MAC Address 0: No 1: Yes |
| 1.3.6.1.4.1.4756.20.732.20.1.238 | Columnf2000EASAggrDestinationMACAddrRemoteB | read-write | current | f2000EAS Series card Aggregation Mode Configuration: Destination MAC Address 0: No 1: Yes |
| 1.3.6.1.4.1.4756.20.732.20.1.239 | Columnf2000EASAggrIPAddrRemoteB | read-write | current | f2000EAS Series card Aggregation Mode Configuration: IP Address 0: No 1: Yes |
| 1.3.6.1.4.1.4756.20.732.20.1.240 | Columnf2000EASAggrTCPUDPPortNumRemoteB | read-write | current | f2000EAS Series card Aggregation Mode Configuration: TCP/UDP Port Number 0: No 1: Yes |
| 1.3.6.1.4.1.4756.20.732.20.1.241 | Columnf2000EASAggrGroupPort1ConfRemoteB | read-write | current | f2000EAS Series card Aggregation Group Port1 Configuration: 0: Normal 1: ID1 2: ID2 |
| 1.3.6.1.4.1.4756.20.732.20.1.242 | Columnf2000EASAggrGroupPort2ConfRemoteB | read-write | current | f2000EAS Series card Aggregation Group Port2 Configuration: 0: Normal 1: ID1 2: ID2 |
| 1.3.6.1.4.1.4756.20.732.20.1.243 | Columnf2000EASAggrGroupPort3ConfRemoteB | read-write | current | f2000EAS Series card Aggregation Group Port3 Configuration: 0: Normal 1: ID1 2: ID2 |
| 1.3.6.1.4.1.4756.20.732.20.1.244 | Columnf2000EASAggrGroupPort4ConfRemoteB | read-write | current | f2000EAS Series card Aggregation Group Port4 Configuration: 0: Normal 1: ID1 2: ID2 |
| 1.3.6.1.4.1.4756.20.732.20.1.245 | Columnf2000EASPort1LACPEnabledRemoteB | read-write | current | f2000EAS Series card Port1 LACP Enabled: 0: No 1: Yes |
| 1.3.6.1.4.1.4756.20.732.20.1.246 | Columnf2000EASPort1LACPKEYRemoteB | read-write | current | f2000EAS Series card Port1 LACP Key value: The Key value incurred by the port, range 0-65535.The value of 0 means auto. |
| 1.3.6.1.4.1.4756.20.732.20.1.247 | Columnf2000EASPort1LACPRoleRemoteB | read-write | current | f2000EAS Series card Port1 LACP Role: 0: Passive 1: Active |
| 1.3.6.1.4.1.4756.20.732.20.1.248 | Columnf2000EASPort1LACPTimeOutRemoteB | read-write | current | f2000EAS Series card Port1 LACP Time out: 0: Slow 1: Fast |
| 1.3.6.1.4.1.4756.20.732.20.1.249 | Columnf2000EASPort1LACPPrioRemoteB | read-write | current | f2000EAS Series card Port1 LACP priority: The Key value incurred by the port, range 1-65535. |
| 1.3.6.1.4.1.4756.20.732.20.1.250 | Columnf2000EASPort2LACPEnabledRemoteB | read-write | current | f2000EAS Series card Port2 LACP Enabled: 0: No 1: Yes |
| 1.3.6.1.4.1.4756.20.732.20.1.251 | Columnf2000EASPort2LACPKEYRemoteB | read-write | current | f2000EAS Series card Port2 LACP Key value: The Key value incurred by the port, range 0-65535.The value of 0 means auto. |
| 1.3.6.1.4.1.4756.20.732.20.1.252 | Columnf2000EASPort2LACPRoleRemoteB | read-write | current | f2000EAS Series card Port2 LACP Role: 0: Passive 1: Active |
| 1.3.6.1.4.1.4756.20.732.20.1.253 | Columnf2000EASPort2LACPTimeOutRemoteB | read-write | current | f2000EAS Series card Port2 LACP Time out: 0: Slow 1: Fast |
| 1.3.6.1.4.1.4756.20.732.20.1.254 | Columnf2000EASPort2LACPPrioRemoteB | read-write | current | f2000EAS Series card Port2 LACP priority: The Key value incurred by the port, range 1-65535. |
| 1.3.6.1.4.1.4756.20.732.20.1.255 | Columnf2000EASPort3LACPEnabledRemoteB | read-write | current | f2000EAS Series card Port3 LACP Enabled: 0: No 1: Yes |
| 1.3.6.1.4.1.4756.20.732.20.1.256 | Columnf2000EASPort3LACPKEYRemoteB | read-write | current | f2000EAS Series card Port3 LACP Key value: The Key value incurred by the port, range 0-65535.The value of 0 means auto. |
| 1.3.6.1.4.1.4756.20.732.20.1.257 | Columnf2000EASPort3LACPRoleRemoteB | read-write | current | f2000EAS Series card Port3 LACP Role: 0: Passive 1: Active |
| 1.3.6.1.4.1.4756.20.732.20.1.258 | Columnf2000EASPort3LACPTimeOutRemoteB | read-write | current | f2000EAS Series card Port3 LACP Time out: 0: Slow 1: Fast |
| 1.3.6.1.4.1.4756.20.732.20.1.259 | Columnf2000EASPort3LACPPrioRemoteB | read-write | current | f2000EAS Series card Port3 LACP priority: The Key value incurred by the port, range 1-65535. |
| 1.3.6.1.4.1.4756.20.732.20.1.260 | Columnf2000EASPort4LACPEnabledRemoteB | read-write | current | f2000EAS Series card Port4 LACP Enabled: 0: No 1: Yes |
| 1.3.6.1.4.1.4756.20.732.20.1.261 | Columnf2000EASPort4LACPKEYRemoteB | read-write | current | f2000EAS Series card Port4 LACP Key value: The Key value incurred by the port, range 0-65535.The value of 0 means auto. |
| 1.3.6.1.4.1.4756.20.732.20.1.262 | Columnf2000EASPort4LACPRoleRemoteB | read-write | current | f2000EAS Series card Port4 LACP Role: 0: Passive 1: Active |
| 1.3.6.1.4.1.4756.20.732.20.1.263 | Columnf2000EASPort4LACPTimeOutRemoteB | read-write | current | f2000EAS Series card Port4 LACP Time out: 0: Slow 1: Fast |
| 1.3.6.1.4.1.4756.20.732.20.1.264 | Columnf2000EASPort4LACPPrioRemoteB | read-write | current | f2000EAS Series card Port4 LACP priority: The Key value incurred by the port, range 1-65535. |
| 1.3.6.1.4.1.4756.20.732.20.1.265 | Columnf2000EASPort1LACPstsRemoteB | read-only | current | f2000EAS Series card Port1 LACP status: 0: No 1: Yes 2: Standby |
| 1.3.6.1.4.1.4756.20.732.20.1.266 | Columnf2000EASPort1LACPKEYstsRemoteB | read-only | current | f2000EAS Series card Port1 LACP status: Key |
| 1.3.6.1.4.1.4756.20.732.20.1.267 | Columnf2000EASPort1LACPAggrIDstsRemoteB | read-only | current | f2000EAS Series card Port1 LACP status: Aggr ID |
| 1.3.6.1.4.1.4756.20.732.20.1.268 | Columnf2000EASPort1LACPParnterSysIDstsRemoteB | read-only | current | f2000EAS Series card Port1 LACP status: Parnter System ID |
| 1.3.6.1.4.1.4756.20.732.20.1.269 | Columnf2000EASPort1LACPParnterPortstsRemoteB | read-only | current | f2000EAS Series card Port1 LACP status: Parnter Port Status |
| 1.3.6.1.4.1.4756.20.732.20.1.270 | Columnf2000EASPort1LACPParnterProistsRemoteB | read-only | current | f2000EAS Series card Port1 LACP status: Parnter Priority |
| 1.3.6.1.4.1.4756.20.732.20.1.271 | Columnf2000EASPort2LACPstsRemoteB | read-only | current | f2000EAS Series card Port2 LACP status: 0: No 1: Yes 2: Standby |
| 1.3.6.1.4.1.4756.20.732.20.1.272 | Columnf2000EASPort2LACPKEYstsRemoteB | read-only | current | f2000EAS Series card Port2 LACP status: Key |
| 1.3.6.1.4.1.4756.20.732.20.1.273 | Columnf2000EASPort2LACPAggrIDstsRemoteB | read-only | current | f2000EAS Series card Port2 LACP status: Aggr ID |
| 1.3.6.1.4.1.4756.20.732.20.1.274 | Columnf2000EASPort2LACPParnterSysIDstsRemoteB | read-only | current | f2000EAS Series card Port2 LACP status: Parnter System ID |
| 1.3.6.1.4.1.4756.20.732.20.1.275 | Columnf2000EASPort2LACPParnterPortstsRemoteB | read-only | current | f2000EAS Series card Port2 LACP status: Parnter Port Status |
| 1.3.6.1.4.1.4756.20.732.20.1.276 | Columnf2000EASPort2LACPParnterProistsRemoteB | read-only | current | f2000EAS Series card Port2 LACP status: Parnter Priority |
| 1.3.6.1.4.1.4756.20.732.20.1.277 | Columnf2000EASPort3LACPstsRemoteB | read-only | current | f2000EAS Series card Port3 LACP status: 0: No 1: Yes 2: Standby |
| 1.3.6.1.4.1.4756.20.732.20.1.278 | Columnf2000EASPort3LACPKEYstsRemoteB | read-only | current | f2000EAS Series card Port3 LACP status: Key |
| 1.3.6.1.4.1.4756.20.732.20.1.279 | Columnf2000EASPort3LACPAggrIDstsRemoteB | read-only | current | f2000EAS Series card Port3 LACP status: Aggr ID |
| 1.3.6.1.4.1.4756.20.732.20.1.280 | Columnf2000EASPort3LACPParnterSysIDstsRemoteB | read-only | current | f2000EAS Series card Port3 LACP status: Parnter System ID |
| 1.3.6.1.4.1.4756.20.732.20.1.281 | Columnf2000EASPort3LACPParnterPortstsRemoteB | read-only | current | f2000EAS Series card Port3 LACP status: Parnter Port Status |
| 1.3.6.1.4.1.4756.20.732.20.1.282 | Columnf2000EASPort3LACPParnterProistsRemoteB | read-only | current | f2000EAS Series card Port3 LACP status: Parnter Priority |
| 1.3.6.1.4.1.4756.20.732.20.1.283 | Columnf2000EASPort4LACPstsRemoteB | read-only | current | f2000EAS Series card Port4 LACP status: 0: No 1: Yes 2: Standby |
| 1.3.6.1.4.1.4756.20.732.20.1.284 | Columnf2000EASPort4LACPKEYstsRemoteB | read-only | current | f2000EAS Series card Port4 LACP status: Key |
| 1.3.6.1.4.1.4756.20.732.20.1.285 | Columnf2000EASPort4LACPAggrIDstsRemoteB | read-only | current | f2000EAS Series card Port4 LACP status: Aggr ID |
| 1.3.6.1.4.1.4756.20.732.20.1.286 | Columnf2000EASPort4LACPParnterSysIDstsRemoteB | read-only | current | f2000EAS Series card Port4 LACP status: Parnter System ID |
| 1.3.6.1.4.1.4756.20.732.20.1.287 | Columnf2000EASPort4LACPParnterPortstsRemoteB | read-only | current | f2000EAS Series card Port4 LACP status: Parnter Port Status |
| 1.3.6.1.4.1.4756.20.732.20.1.288 | Columnf2000EASPort4LACPParnterProistsRemoteB | read-only | current | f2000EAS Series card Port4 LACP status: Parnter Priority |
| 1.3.6.1.4.1.4756.20.732.20.1.289 | Columnf2000EASOAMPort1EnableRemoteB | read-only | current | f2000EAS Series card Port1 OAM: 0: Off 1: On |
| 1.3.6.1.4.1.4756.20.732.20.1.290 | Columnf2000EASOAMPort1ModeRemoteB | read-write | current | f2000EAS Series card Port1 OAM: 0: Passive 1: Active |
| 1.3.6.1.4.1.4756.20.732.20.1.291 | Columnf2000EASOAMPort1LoopBackRemoteB | read-write | current | f2000EAS Series card Port1 OAM LoopBack: 0: Off 1: On |
| 1.3.6.1.4.1.4756.20.732.20.1.292 | Columnf2000EASOAMPort1LinkMonitorRemoteB | read-write | current | f2000EAS Series card Port1 OAM Link Monitor: 0: Off 1: On |
| 1.3.6.1.4.1.4756.20.732.20.1.293 | Columnf2000EASOAMPort1MIBRetrievalRemoteB | read-write | current | f2000EAS Series card Port1 OAM MIB Retrieval: 0: Off 1: On |
| 1.3.6.1.4.1.4756.20.732.20.1.294 | Columnf2000EASOAMPort1LoopBackOPRemoteB | read-only | current | f2000EAS Series card Port1 OAM LoopBack operation: 0: Off 1: On |
| 1.3.6.1.4.1.4756.20.732.20.1.295 | Columnf2000EASOAMPort2EnableRemoteB | read-only | current | f2000EAS Series card Port2 OAM: 0: Off 1: On |
| 1.3.6.1.4.1.4756.20.732.20.1.296 | Columnf2000EASOAMPort2ModeRemoteB | read-write | current | f2000EAS Series card Port2 OAM: 0: Passive 1: Active |
| 1.3.6.1.4.1.4756.20.732.20.1.297 | Columnf2000EASOAMPort2LoopBackRemoteB | read-write | current | f2000EAS Series card Port2 OAM LoopBack: 0: Off 1: On |
| 1.3.6.1.4.1.4756.20.732.20.1.298 | Columnf2000EASOAMPort2LinkMonitorRemoteB | read-write | current | f2000EAS Series card Port2 OAM Link Monitor: 0: Off 1: On |
| 1.3.6.1.4.1.4756.20.732.20.1.299 | Columnf2000EASOAMPort2MIBRetrievalRemoteB | read-write | current | f2000EAS Series card Port2 OAM MIB Retrieval: 0: Off 1: On |
| 1.3.6.1.4.1.4756.20.732.20.1.300 | Columnf2000EASOAMPort2LoopBackOPRemoteB | read-only | current | f2000EAS Series card Port2 OAM LoopBack operation: 0: Off 1: On |
| 1.3.6.1.4.1.4756.20.732.20.1.301 | Columnf2000EASOAMPort3EnableRemoteB | read-only | current | f2000EAS Series card Port3 OAM: 0: Off 1: On |
| 1.3.6.1.4.1.4756.20.732.20.1.302 | Columnf2000EASOAMPort3ModeRemoteB | read-write | current | f2000EAS Series card Port3 OAM: 0: Passive 1: Active |
| 1.3.6.1.4.1.4756.20.732.20.1.303 | Columnf2000EASOAMPort3LoopBackRemoteB | read-write | current | f2000EAS Series card Port3 OAM: 0: Off 1: On |
| 1.3.6.1.4.1.4756.20.732.20.1.304 | Columnf2000EASOAMPort3LinkMonitorRemoteB | read-write | current | f2000EAS Series card Port3 OAM Link Monitor: 0: Off 1: On |
| 1.3.6.1.4.1.4756.20.732.20.1.305 | Columnf2000EASOAMPort3MIBRetrievalRemoteB | read-write | current | f2000EAS Series card Port3 OAM MIB Retrieval: 0: Off 1: On |
| 1.3.6.1.4.1.4756.20.732.20.1.306 | Columnf2000EASOAMPort3LoopBackOPRemoteB | read-only | current | f2000EAS Series card Port3 OAM LoopBack operation: 0: Disable 1: Enable |
| 1.3.6.1.4.1.4756.20.732.20.1.307 | Columnf2000EASOAMPort4EnableRemoteB | read-only | current | f2000EAS Series card Port4 OAM: 0: Off 1: On |
| 1.3.6.1.4.1.4756.20.732.20.1.308 | Columnf2000EASOAMPort4ModeRemoteB | read-write | current | f2000EAS Series card Port4 OAM: 0: Passive 1: Active |
| 1.3.6.1.4.1.4756.20.732.20.1.309 | Columnf2000EASOAMPort4LoopBackRemoteB | read-write | current | f2000EAS Series card Port4 OAM: 0: Off 1: On |
| 1.3.6.1.4.1.4756.20.732.20.1.310 | Columnf2000EASOAMPort4LinkMonitorRemoteB | read-write | current | f2000EAS Series card Port4 OAM Link Monitor: 0: Off 1: On |
| 1.3.6.1.4.1.4756.20.732.20.1.311 | Columnf2000EASOAMPort4MIBRetrievalRemoteB | read-write | current | f2000EAS Series card Port4 OAM MIB Retrieval: 0: Off 1: On |
| 1.3.6.1.4.1.4756.20.732.20.1.312 | Columnf2000EASOAMPort4LoopBackOPRemoteB | read-only | current | f2000EAS Series card Port4 OAM LoopBack operation: 0: On 1: Off |
| 1.3.6.1.4.1.4756.20.732.20.1.313 | Columnf2000EASPort1EFEErrorWindowRemoteB | read-write | current | f2000EAS Series card Port1 Link Event Configuration: Error Frame Event - Error Window |
| 1.3.6.1.4.1.4756.20.732.20.1.314 | Columnf2000EASPort1EFEErrorThresholdRemoteB | read-write | current | f2000EAS Series card Port1 Link Event Configuration: Error Frame Event - Error Threshold |
| 1.3.6.1.4.1.4756.20.732.20.1.315 | Columnf2000EASPort1SPEEErrorWindowRemoteB | read-write | current | f2000EAS Series card Port1 Link Event Configuration: Symbol Period Error Event - Error Window |
| 1.3.6.1.4.1.4756.20.732.20.1.316 | Columnf2000EASPort1SPEEErrorThresholdRemoteB | read-write | current | f2000EAS Series card Port1 Link Event Configuration: Symbol Period Error Event - Error Threshold |
| 1.3.6.1.4.1.4756.20.732.20.1.317 | Columnf2000EASPort1SSEErrorWindowRemoteB | read-write | current | f2000EAS Series card Port1 Link Event Configuration: Seconds Summary Event - Error Window |
| 1.3.6.1.4.1.4756.20.732.20.1.318 | Columnf2000EASPort1SSEErrorThresholdRemoteB | read-write | current | f2000EAS Series card Port1 Link Event Configuration: Seconds Summary Event - Error Threshold |
| 1.3.6.1.4.1.4756.20.732.20.1.319 | Columnf2000EASPort2EFEErrorWindowRemoteB | read-write | current | f2000EAS Series card Port2 Link Event Configuration: Error Frame Event - Error Window |
| 1.3.6.1.4.1.4756.20.732.20.1.320 | Columnf2000EASPort2EFEErrorThresholdRemoteB | read-write | current | f2000EAS Series card Port2 Link Event Configuration: Error Frame Event - Error Threshold |
| 1.3.6.1.4.1.4756.20.732.20.1.321 | Columnf2000EASPort2SPEEErrorWindowRemoteB | read-write | current | f2000EAS Series card Port2 Link Event Configuration: Symbol Period Error Event - Error Window |
| 1.3.6.1.4.1.4756.20.732.20.1.322 | Columnf2000EASPort2SPEEErrorThresholdRemoteB | read-write | current | f2000EAS Series card Port2 Link Event Configuration: Symbol Period Error Event - Error Threshold |
| 1.3.6.1.4.1.4756.20.732.20.1.323 | Columnf2000EASPort2SSEErrorWindowRemoteB | read-write | current | f2000EAS Series card Port2 Link Event Configuration: Seconds Summary Event - Error Window |
| 1.3.6.1.4.1.4756.20.732.20.1.324 | Columnf2000EASPort2SSEErrorThresholdRemoteB | read-write | current | f2000EAS Series card Port2 Link Event Configuration: Seconds Summary Event - Error Threshold |
| 1.3.6.1.4.1.4756.20.732.20.1.325 | Columnf2000EASPort3EFEErrorWindowRemoteB | read-write | current | f2000EAS Series card Port3 Link Event Configuration: Error Frame Event - Error Window |
| 1.3.6.1.4.1.4756.20.732.20.1.326 | Columnf2000EASPort3EFEErrorThresholdRemoteB | read-write | current | f2000EAS Series card Port3 Link Event Configuration: Error Frame Event - Error Threshold |
| 1.3.6.1.4.1.4756.20.732.20.1.327 | Columnf2000EASPort3SPEEErrorWindowRemoteB | read-write | current | f2000EAS Series card Port3 Link Event Configuration: Symbol Period Error Event - Error Window |
| 1.3.6.1.4.1.4756.20.732.20.1.328 | Columnf2000EASPort3SPEEErrorThresholdRemoteB | read-write | current | f2000EAS Series card Port3 Link Event Configuration: Symbol Period Error Event - Error Threshold |
| 1.3.6.1.4.1.4756.20.732.20.1.329 | Columnf2000EASPort3SSEErrorWindowRemoteB | read-write | current | f2000EAS Series card Port3 Link Event Configuration: Seconds Summary Event - Error Window |
| 1.3.6.1.4.1.4756.20.732.20.1.330 | Columnf2000EASPort3SSEErrorThresholdRemoteB | read-write | current | f2000EAS Series card Port3 Link Event Configuration: Seconds Summary Event - Error Threshold |
| 1.3.6.1.4.1.4756.20.732.20.1.331 | Columnf2000EASPort4EFEErrorWindowRemoteB | read-write | current | f2000EAS Series card Port4 Link Event Configuration: Error Frame Event - Error Window |
| 1.3.6.1.4.1.4756.20.732.20.1.332 | Columnf2000EASPort4EFEErrorThresholdRemoteB | read-write | current | f2000EAS Series card Port4 Link Event Configuration: Error Frame Event - Error Threshold |
| 1.3.6.1.4.1.4756.20.732.20.1.333 | Columnf2000EASPort4SPEEErrorWindowRemoteB | read-write | current | f2000EAS Series card Port4 Link Event Configuration: Symbol Period Error Event - Error Window |
| 1.3.6.1.4.1.4756.20.732.20.1.334 | Columnf2000EASPort4SPEEErrorThresholdRemoteB | read-write | current | f2000EAS Series card Port4 Link Event Configuration: Symbol Period Error Event - Error Threshold |
| 1.3.6.1.4.1.4756.20.732.20.1.335 | Columnf2000EASPort4SSEErrorWindowRemoteB | read-write | current | f2000EAS Series card Port4 Link Event Configuration: Seconds Summary Event - Error Window |
| 1.3.6.1.4.1.4756.20.732.20.1.336 | Columnf2000EASPort4SSEErrorThresholdRemoteB | read-write | current | f2000EAS Series card Port4 Link Event Configuration: Seconds Summary Event - Error Threshold |
| 1.3.6.1.4.1.4756.20.732.20.1.337 | Columnf2000EASPort1RxOAMInfoPDURemoteB | read-only | current | f2000EAS Series card Port1 Detailed Link OAM Statistics: Rx OAM Information PDU's |
| 1.3.6.1.4.1.4756.20.732.20.1.338 | Columnf2000EASPort1RxUniqueErrorEventRemoteB | read-only | current | f2000EAS Series card Port1 Detailed Link OAM Statistics: Rx Unique Error Event Notificatio |
| 1.3.6.1.4.1.4756.20.732.20.1.339 | Columnf2000EASPort1RxDuplicateErrorEventRemoteB | read-only | current | f2000EAS Series card Port1 Detailed Link OAM Statistics: Rx Duplicate Error Event Notification |
| 1.3.6.1.4.1.4756.20.732.20.1.340 | Columnf2000EASPort1RxLoopBackControlRemoteB | read-only | current | f2000EAS Series card Port1 Detailed Link OAM Statistics: Rx Loopback Control |
| 1.3.6.1.4.1.4756.20.732.20.1.341 | Columnf2000EASPort1RxVariableRequestRemoteB | read-only | current | f2000EAS Series card Port1 Detailed Link OAM Statistics: Rx Variable Request |
| 1.3.6.1.4.1.4756.20.732.20.1.342 | Columnf2000EASPort1RxVariableResponseRemoteB | read-only | current | f2000EAS Series card Port1 Detailed Link OAM Statistics: Rx Variable Response |
| 1.3.6.1.4.1.4756.20.732.20.1.343 | Columnf2000EASPort1RxOrgSpecificPDURemoteB | read-only | current | f2000EAS Series card Port1 Detailed Link OAM Statistics: Rx Org Specific PDU's |
| 1.3.6.1.4.1.4756.20.732.20.1.344 | Columnf2000EASPort1RxUnsupportedCodesRemoteB | read-only | current | f2000EAS Series card Port1 Detailed Link OAM Statistics: Rx Unsupported Codes |
| 1.3.6.1.4.1.4756.20.732.20.1.345 | Columnf2000EASPort1RxLinkFaultPDURemoteB | read-only | current | f2000EAS Series card Port1 Detailed Link OAM Statistics: Rx Link Fault PDU's |
| 1.3.6.1.4.1.4756.20.732.20.1.346 | Columnf2000EASPort1RxDyingGaspRemoteB | read-only | current | f2000EAS Series card Port1 Detailed Link OAM Statistics: Rx Dying Gasp |
| 1.3.6.1.4.1.4756.20.732.20.1.347 | Columnf2000EASPort1RxCriticalEventPDURemoteB | read-only | current | f2000EAS Series card Port1 Detailed Link OAM Statistics: Rx Dying Gasp |
| 1.3.6.1.4.1.4756.20.732.20.1.348 | Columnf2000EASPort1TxOAMInfoPDURemoteB | read-only | current | f2000EAS Series card Port1 Detailed Link OAM Statistics: Tx OAM Information PDU's |
| 1.3.6.1.4.1.4756.20.732.20.1.349 | Columnf2000EASPort1TxUniqueErrorEventRemoteB | read-only | current | f2000EAS Series card Port1 Detailed Link OAM Statistics: Tx Unique Error Event Notificatio |
| 1.3.6.1.4.1.4756.20.732.20.1.350 | Columnf2000EASPort1TxDuplicateErrorEventRemoteB | read-only | current | f2000EAS Series card Port1 Detailed Link OAM Statistics: Tx Duplicate Error Event Notification |
| 1.3.6.1.4.1.4756.20.732.20.1.351 | Columnf2000EASPort1TxLoopBackControlRemoteB | read-only | current | f2000EAS Series card Port1 Detailed Link OAM Statistics: Tx Loopback Control |
| 1.3.6.1.4.1.4756.20.732.20.1.352 | Columnf2000EASPort1TxVariableRequestRemoteB | read-only | current | f2000EAS Series card Port1 Detailed Link OAM Statistics: Tx Variable Request |
| 1.3.6.1.4.1.4756.20.732.20.1.353 | Columnf2000EASPort1TxVariableResponseRemoteB | read-only | current | f2000EAS Series card Port1 Detailed Link OAM Statistics: Tx Variable Response |
| 1.3.6.1.4.1.4756.20.732.20.1.354 | Columnf2000EASPort1TxOrgSpecificPDURemoteB | read-only | current | f2000EAS Series card Port1 Detailed Link OAM Statistics: Tx Org Specific PDU's |
| 1.3.6.1.4.1.4756.20.732.20.1.355 | Columnf2000EASPort1TxUnsupportedCodesRemoteB | read-only | current | f2000EAS Series card Port1 Detailed Link OAM Statistics: Tx Unsupported Codes |
| 1.3.6.1.4.1.4756.20.732.20.1.356 | Columnf2000EASPort1TxLinkFaultPDURemoteB | read-only | current | f2000EAS Series card Port1 Detailed Link OAM Statistics: Tx Link Fault PDU's |
| 1.3.6.1.4.1.4756.20.732.20.1.357 | Columnf2000EASPort1TxDyingGaspRemoteB | read-only | current | f2000EAS Series card Port1 Detailed Link OAM Statistics: Tx Dying Gasp |
| 1.3.6.1.4.1.4756.20.732.20.1.358 | Columnf2000EASPort1TxCriticalEventPDURemoteB | read-only | current | f2000EAS Series card Port1 Detailed Link OAM Statistics: Tx Dying Gasp |
| 1.3.6.1.4.1.4756.20.732.20.1.359 | Columnf2000EASPort2RxOAMInfoPDURemoteB | read-only | current | f2000EAS Series card Port2 Detailed Link OAM Statistics: Rx OAM Information PDU's |
| 1.3.6.1.4.1.4756.20.732.20.1.360 | Columnf2000EASPort2RxUniqueErrorEventRemoteB | read-only | current | f2000EAS Series card Port2 Detailed Link OAM Statistics: Rx Unique Error Event Notificatio |
| 1.3.6.1.4.1.4756.20.732.20.1.361 | Columnf2000EASPort2RxDuplicateErrorEventRemoteB | read-only | current | f2000EAS Series card Port2 Detailed Link OAM Statistics: Rx Duplicate Error Event Notification |
| 1.3.6.1.4.1.4756.20.732.20.1.362 | Columnf2000EASPort2RxLoopBackControlRemoteB | read-only | current | f2000EAS Series card Port2 Detailed Link OAM Statistics: Rx Loopback Control |
| 1.3.6.1.4.1.4756.20.732.20.1.363 | Columnf2000EASPort2RxVariableRequestRemoteB | read-only | current | f2000EAS Series card Port2 Detailed Link OAM Statistics: Rx Variable Request |
| 1.3.6.1.4.1.4756.20.732.20.1.364 | Columnf2000EASPort2RxVariableResponseRemoteB | read-only | current | f2000EAS Series card Port2 Detailed Link OAM Statistics: Rx Variable Response |
| 1.3.6.1.4.1.4756.20.732.20.1.365 | Columnf2000EASPort2RxOrgSpecificPDURemoteB | read-only | current | f2000EAS Series card Port2 Detailed Link OAM Statistics: Rx Org Specific PDU's |
| 1.3.6.1.4.1.4756.20.732.20.1.366 | Columnf2000EASPort2RxUnsupportedCodesRemoteB | read-only | current | f2000EAS Series card Port2 Detailed Link OAM Statistics: Rx Unsupported Codes |
| 1.3.6.1.4.1.4756.20.732.20.1.367 | Columnf2000EASPort2RxLinkFaultPDURemoteB | read-only | current | f2000EAS Series card Port2 Detailed Link OAM Statistics: Rx Link Fault PDU's |
| 1.3.6.1.4.1.4756.20.732.20.1.368 | Columnf2000EASPort2RxDyingGaspRemoteB | read-only | current | f2000EAS Series card Port2 Detailed Link OAM Statistics: Rx Dying Gasp |
| 1.3.6.1.4.1.4756.20.732.20.1.369 | Columnf2000EASPort2RxCriticalEventPDURemoteB | read-only | current | f2000EAS Series card Port2 Detailed Link OAM Statistics: Rx Dying Gasp |
| 1.3.6.1.4.1.4756.20.732.20.1.370 | Columnf2000EASPort2TxOAMInfoPDURemoteB | read-only | current | f2000EAS Series card Port2 Detailed Link OAM Statistics: Tx OAM Information PDU's |
| 1.3.6.1.4.1.4756.20.732.20.1.371 | Columnf2000EASPort2TxUniqueErrorEventRemoteB | read-only | current | f2000EAS Series card Port2 Detailed Link OAM Statistics: Tx Unique Error Event Notificatio |
| 1.3.6.1.4.1.4756.20.732.20.1.372 | Columnf2000EASPort2TxDuplicateErrorEventRemoteB | read-only | current | f2000EAS Series card Port2 Detailed Link OAM Statistics: Tx Duplicate Error Event Notification |
| 1.3.6.1.4.1.4756.20.732.20.1.373 | Columnf2000EASPort2TxLoopBackControlRemoteB | read-only | current | f2000EAS Series card Port2 Detailed Link OAM Statistics: Tx Loopback Control |
| 1.3.6.1.4.1.4756.20.732.20.1.374 | Columnf2000EASPort2TxVariableRequestRemoteB | read-only | current | f2000EAS Series card Port2 Detailed Link OAM Statistics: Tx Variable Request |
| 1.3.6.1.4.1.4756.20.732.20.1.375 | Columnf2000EASPort2TxVariableResponseRemoteB | read-only | current | f2000EAS Series card Port2 Detailed Link OAM Statistics: Tx Variable Response |
| 1.3.6.1.4.1.4756.20.732.20.1.376 | Columnf2000EASPort2TxOrgSpecificPDURemoteB | read-only | current | f2000EAS Series card Port2 Detailed Link OAM Statistics: Tx Org Specific PDU's |
| 1.3.6.1.4.1.4756.20.732.20.1.377 | Columnf2000EASPort2TxUnsupportedCodesRemoteB | read-only | current | f2000EAS Series card Port2 Detailed Link OAM Statistics: Tx Unsupported Codes |
| 1.3.6.1.4.1.4756.20.732.20.1.378 | Columnf2000EASPort2TxLinkFaultPDURemoteB | read-only | current | f2000EAS Series card Port2 Detailed Link OAM Statistics: Tx Link Fault PDU's |
| 1.3.6.1.4.1.4756.20.732.20.1.379 | Columnf2000EASPort2TxDyingGaspRemoteB | read-only | current | f2000EAS Series card Port2 Detailed Link OAM Statistics: Tx Dying Gasp |
| 1.3.6.1.4.1.4756.20.732.20.1.380 | Columnf2000EASPort2TxCriticalEventPDURemoteB | read-only | current | f2000EAS Series card Port2 Detailed Link OAM Statistics: Tx Dying Gasp |
| 1.3.6.1.4.1.4756.20.732.20.1.381 | Columnf2000EASPort3RxOAMInfoPDURemoteB | read-only | current | f2000EAS Series card Port3 Detailed Link OAM Statistics: Rx OAM Information PDU's |
| 1.3.6.1.4.1.4756.20.732.20.1.382 | Columnf2000EASPort3RxUniqueErrorEventRemoteB | read-only | current | f2000EAS Series card Port3 Detailed Link OAM Statistics: Rx Unique Error Event Notificatio |
| 1.3.6.1.4.1.4756.20.732.20.1.383 | Columnf2000EASPort3RxDuplicateErrorEventRemoteB | read-only | current | f2000EAS Series card Port3 Detailed Link OAM Statistics: Rx Duplicate Error Event Notification |
| 1.3.6.1.4.1.4756.20.732.20.1.384 | Columnf2000EASPort3RxLoopBackControlRemoteB | read-only | current | f2000EAS Series card Port3 Detailed Link OAM Statistics: Rx Loopback Control |
| 1.3.6.1.4.1.4756.20.732.20.1.385 | Columnf2000EASPort3RxVariableRequestRemoteB | read-only | current | f2000EAS Series card Port3 Detailed Link OAM Statistics: Rx Variable Request |
| 1.3.6.1.4.1.4756.20.732.20.1.386 | Columnf2000EASPort3RxVariableResponseRemoteB | read-only | current | f2000EAS Series card Port3 Detailed Link OAM Statistics: Rx Variable Response |
| 1.3.6.1.4.1.4756.20.732.20.1.387 | Columnf2000EASPort3RxOrgSpecificPDURemoteB | read-only | current | f2000EAS Series card Port3 Detailed Link OAM Statistics: Rx Org Specific PDU's |
| 1.3.6.1.4.1.4756.20.732.20.1.388 | Columnf2000EASPort3RxUnsupportedCodesRemoteB | read-only | current | f2000EAS Series card Port3 Detailed Link OAM Statistics: Rx Unsupported Codes |
| 1.3.6.1.4.1.4756.20.732.20.1.389 | Columnf2000EASPort3RxLinkFaultPDURemoteB | read-only | current | f2000EAS Series card Port3 Detailed Link OAM Statistics: Rx Link Fault PDU's |
| 1.3.6.1.4.1.4756.20.732.20.1.390 | Columnf2000EASPort3RxDyingGaspRemoteB | read-only | current | f2000EAS Series card Port3 Detailed Link OAM Statistics: Rx Dying Gasp |
| 1.3.6.1.4.1.4756.20.732.20.1.391 | Columnf2000EASPort3RxCriticalEventPDURemoteB | read-only | current | f2000EAS Series card Port3 Detailed Link OAM Statistics: Rx Dying Gasp |
| 1.3.6.1.4.1.4756.20.732.20.1.392 | Columnf2000EASPort3TxOAMInfoPDURemoteB | read-only | current | f2000EAS Series card Port3 Detailed Link OAM Statistics: Tx OAM Information PDU's |
| 1.3.6.1.4.1.4756.20.732.20.1.393 | Columnf2000EASPort3TxUniqueErrorEventRemoteB | read-only | current | f2000EAS Series card Port3 Detailed Link OAM Statistics: Tx Unique Error Event Notificatio |
| 1.3.6.1.4.1.4756.20.732.20.1.394 | Columnf2000EASPort3TxDuplicateErrorEventRemoteB | read-only | current | f2000EAS Series card Port3 Detailed Link OAM Statistics: Tx Duplicate Error Event Notification |
| 1.3.6.1.4.1.4756.20.732.20.1.395 | Columnf2000EASPort3TxLoopBackControlRemoteB | read-only | current | f2000EAS Series card Port3 Detailed Link OAM Statistics: Tx Loopback Control |
| 1.3.6.1.4.1.4756.20.732.20.1.396 | Columnf2000EASPort3TxVariableRequestRemoteB | read-only | current | f2000EAS Series card Port3 Detailed Link OAM Statistics: Tx Variable Request |
| 1.3.6.1.4.1.4756.20.732.20.1.397 | Columnf2000EASPort3TxVariableResponseRemoteB | read-only | current | f2000EAS Series card Port3 Detailed Link OAM Statistics: Tx Variable Response |
| 1.3.6.1.4.1.4756.20.732.20.1.398 | Columnf2000EASPort3TxOrgSpecificPDURemoteB | read-only | current | f2000EAS Series card Port3 Detailed Link OAM Statistics: Tx Org Specific PDU's |
| 1.3.6.1.4.1.4756.20.732.20.1.399 | Columnf2000EASPort3TxUnsupportedCodesRemoteB | read-only | current | f2000EAS Series card Port3 Detailed Link OAM Statistics: Tx Unsupported Codes |
| 1.3.6.1.4.1.4756.20.732.20.1.400 | Columnf2000EASPort3TxLinkFaultPDURemoteB | read-only | current | f2000EAS Series card Port3 Detailed Link OAM Statistics: Tx Link Fault PDU's |
| 1.3.6.1.4.1.4756.20.732.20.1.401 | Columnf2000EASPort3TxDyingGaspRemoteB | read-only | current | f2000EAS Series card Port3 Detailed Link OAM Statistics: Tx Dying Gasp |
| 1.3.6.1.4.1.4756.20.732.20.1.402 | Columnf2000EASPort3TxCriticalEventPDURemoteB | read-only | current | f2000EAS Series card Port3 Detailed Link OAM Statistics: Tx Dying Gasp |
| 1.3.6.1.4.1.4756.20.732.20.1.403 | Columnf2000EASPort4RxOAMInfoPDURemoteB | read-only | current | f2000EAS Series card Port4 Detailed Link OAM Statistics: Rx OAM Information PDU's |
| 1.3.6.1.4.1.4756.20.732.20.1.404 | Columnf2000EASPort4RxUniqueErrorEventRemoteB | read-only | current | f2000EAS Series card Port4 Detailed Link OAM Statistics: Rx Unique Error Event Notificatio |
| 1.3.6.1.4.1.4756.20.732.20.1.405 | Columnf2000EASPort4RxDuplicateErrorEventRemoteB | read-only | current | f2000EAS Series card Port4 Detailed Link OAM Statistics: Rx Duplicate Error Event Notification |
| 1.3.6.1.4.1.4756.20.732.20.1.406 | Columnf2000EASPort4RxLoopBackControlRemoteB | read-only | current | f2000EAS Series card Port4 Detailed Link OAM Statistics: Rx Loopback Control |
| 1.3.6.1.4.1.4756.20.732.20.1.407 | Columnf2000EASPort4RxVariableRequestRemoteB | read-only | current | f2000EAS Series card Port4 Detailed Link OAM Statistics: Rx Variable Request |
| 1.3.6.1.4.1.4756.20.732.20.1.408 | Columnf2000EASPort4RxVariableResponseRemoteB | read-only | current | f2000EAS Series card Port4 Detailed Link OAM Statistics: Rx Variable Response |
| 1.3.6.1.4.1.4756.20.732.20.1.409 | Columnf2000EASPort4RxOrgSpecificPDURemoteB | read-only | current | f2000EAS Series card Port4 Detailed Link OAM Statistics: Rx Org Specific PDU's |
| 1.3.6.1.4.1.4756.20.732.20.1.410 | Columnf2000EASPort4RxUnsupportedCodesRemoteB | read-only | current | f2000EAS Series card Port4 Detailed Link OAM Statistics: Rx Unsupported Codes |
| 1.3.6.1.4.1.4756.20.732.20.1.411 | Columnf2000EASPort4RxLinkFaultPDURemoteB | read-only | current | f2000EAS Series card Port4 Detailed Link OAM Statistics: Rx Link Fault PDU's |
| 1.3.6.1.4.1.4756.20.732.20.1.412 | Columnf2000EASPort4RxDyingGaspRemoteB | read-only | current | f2000EAS Series card Port4 Detailed Link OAM Statistics: Rx Dying Gasp |
| 1.3.6.1.4.1.4756.20.732.20.1.413 | Columnf2000EASPort4RxCriticalEventPDURemoteB | read-only | current | f2000EAS Series card Port4 Detailed Link OAM Statistics: Rx Dying Gasp |
| 1.3.6.1.4.1.4756.20.732.20.1.414 | Columnf2000EASPort4TxOAMInfoPDURemoteB | read-only | current | f2000EAS Series card Port4 Detailed Link OAM Statistics: Tx OAM Information PDU's |
| 1.3.6.1.4.1.4756.20.732.20.1.415 | Columnf2000EASPort4TxUniqueErrorEventRemoteB | read-only | current | f2000EAS Series card Port4 Detailed Link OAM Statistics: Tx Unique Error Event Notificatio |
| 1.3.6.1.4.1.4756.20.732.20.1.416 | Columnf2000EASPort4TxDuplicateErrorEventRemoteB | read-only | current | f2000EAS Series card Port4 Detailed Link OAM Statistics: Tx Duplicate Error Event Notification |
| 1.3.6.1.4.1.4756.20.732.20.1.417 | Columnf2000EASPort4TxLoopBackControlRemoteB | read-only | current | f2000EAS Series card Port4 Detailed Link OAM Statistics: Tx Loopback Control |
| 1.3.6.1.4.1.4756.20.732.20.1.418 | Columnf2000EASPort4TxVariableRequestRemoteB | read-only | current | f2000EAS Series card Port4 Detailed Link OAM Statistics: Tx Variable Request |
| 1.3.6.1.4.1.4756.20.732.20.1.419 | Columnf2000EASPort4TxVariableResponseRemoteB | read-only | current | f2000EAS Series card Port4 Detailed Link OAM Statistics: Tx Variable Response |
| 1.3.6.1.4.1.4756.20.732.20.1.420 | Columnf2000EASPort4TxOrgSpecificPDURemoteB | read-only | current | f2000EAS Series card Port4 Detailed Link OAM Statistics: Tx Org Specific PDU's |
| 1.3.6.1.4.1.4756.20.732.20.1.421 | Columnf2000EASPort4TxUnsupportedCodesRemoteB | read-only | current | f2000EAS Series card Port4 Detailed Link OAM Statistics: Tx Unsupported Codes |
| 1.3.6.1.4.1.4756.20.732.20.1.422 | Columnf2000EASPort4TxLinkFaultPDURemoteB | read-only | current | f2000EAS Series card Port4 Detailed Link OAM Statistics: Tx Link Fault PDU's |
| 1.3.6.1.4.1.4756.20.732.20.1.423 | Columnf2000EASPort4TxDyingGaspRemoteB | read-only | current | f2000EAS Series card Port4 Detailed Link OAM Statistics: Tx Dying Gasp |
| 1.3.6.1.4.1.4756.20.732.20.1.424 | Columnf2000EASPort4TxCriticalEventPDURemoteB | read-only | current | f2000EAS Series card Port4 Detailed Link OAM Statistics: Tx Dying Gasp |
| 1.3.6.1.4.1.4756.20.732.20.1.425 | Columnf2000EASPort1PDUPermisionRemoteB | read-only | current | f2000EAS Series card Detailed Link OAM Status for Port 1: PDU Permission |
| 1.3.6.1.4.1.4756.20.732.20.1.426 | Columnf2000EASPort1DiscoveryStateRemoteB | read-only | current | f2000EAS Series card Detailed Link OAM Status for Port 1: Discovery State |
| 1.3.6.1.4.1.4756.20.732.20.1.427 | Columnf2000EASPort1PeerMACAddrRemoteB | read-only | current | f2000EAS Series card Detailed Link OAM Status for Port 1: Discovery State |
| 1.3.6.1.4.1.4756.20.732.20.1.428 | Columnf2000EASPort1LocalModeRemoteB | read-only | current | f2000EAS Series card Detailed Link OAM Status for Port 1: RemoteB: Mode |
| 1.3.6.1.4.1.4756.20.732.20.1.429 | Columnf2000EASPort1LocalUnOperationRemoteB | read-only | current | f2000EAS Series card Detailed Link OAM Status for Port 1: RemoteB: Unidirectional Operation Support |
| 1.3.6.1.4.1.4756.20.732.20.1.430 | Columnf2000EASPort1LocalRemoteLbRemoteB | read-only | current | f2000EAS Series card Detailed Link OAM Status for Port 1: RemoteB: Remote Loopback Support |
| 1.3.6.1.4.1.4756.20.732.20.1.431 | Columnf2000EASPort1LocalLMRemoteB | read-only | current | f2000EAS Series card Detailed Link OAM Status for Port 1: RemoteB: Link Monitoring Support |
| 1.3.6.1.4.1.4756.20.732.20.1.432 | Columnf2000EASPort1LocalMIBRetrievalRemoteB | read-only | current | f2000EAS Series card Detailed Link OAM Status for Port 1: RemoteB: MIB Retrieval Support |
| 1.3.6.1.4.1.4756.20.732.20.1.433 | Columnf2000EASPort1LocalMTUSizeRemoteB | read-only | current | f2000EAS Series card Detailed Link OAM Status for Port 1: RemoteB: MTU Size |
| 1.3.6.1.4.1.4756.20.732.20.1.434 | Columnf2000EASPort1LocalMultiStateRemoteB | read-only | current | f2000EAS Series card Detailed Link OAM Status for Port 1: RemoteB: Multiplexer State |
| 1.3.6.1.4.1.4756.20.732.20.1.435 | Columnf2000EASPort1LocalParserStateRemoteB | read-only | current | f2000EAS Series card Detailed Link OAM Status for Port 1: RemoteB: Multiplexer State |
| 1.3.6.1.4.1.4756.20.732.20.1.436 | Columnf2000EASPort1LocalOUIRemoteB | read-only | current | f2000EAS Series card Detailed Link OAM Status for Port 1: RemoteB: Organizational Unique Identification |
| 1.3.6.1.4.1.4756.20.732.20.1.437 | Columnf2000EASPort1LocalPDURevRemoteB | read-only | current | f2000EAS Series card Detailed Link OAM Status for Port 1: RemoteB: PDU Revision |
| 1.3.6.1.4.1.4756.20.732.20.1.438 | Columnf2000EASPort1PeerModeRemoteB | read-only | current | f2000EAS Series card Detailed Link OAM Status for Port 1: Peer: Mode |
| 1.3.6.1.4.1.4756.20.732.20.1.439 | Columnf2000EASPort1PeerUnOperationRemoteB | read-only | current | f2000EAS Series card Detailed Link OAM Status for Port 1: Peer: Unidirectional Operation Support |
| 1.3.6.1.4.1.4756.20.732.20.1.440 | Columnf2000EASPort1PeerRemoteLbRemoteB | read-only | current | f2000EAS Series card Detailed Link OAM Status for Port 1: Peer: Remote Loopback Support |
| 1.3.6.1.4.1.4756.20.732.20.1.441 | Columnf2000EASPort1PeerLMRemoteB | read-only | current | f2000EAS Series card Detailed Link OAM Status for Port 1: Peer: Link Monitoring Support |
| 1.3.6.1.4.1.4756.20.732.20.1.442 | Columnf2000EASPort1PeerMIBRetrievalRemoteB | read-only | current | f2000EAS Series card Detailed Link OAM Status for Port 1: Peer: MIB Retrieval Support |
| 1.3.6.1.4.1.4756.20.732.20.1.443 | Columnf2000EASPort1PeerMTUSizeRemoteB | read-only | current | f2000EAS Series card Detailed Link OAM Status for Port 1: Peer: MTU Size |
| 1.3.6.1.4.1.4756.20.732.20.1.444 | Columnf2000EASPort1PeerMultiStateRemoteB | read-only | current | f2000EAS Series card Detailed Link OAM Status for Port 1: Peer: Multiplexer State |
| 1.3.6.1.4.1.4756.20.732.20.1.445 | Columnf2000EASPort1PeerParserStateRemoteB | read-only | current | f2000EAS Series card Detailed Link OAM Status for Port 1: Peer: Multiplexer State |
| 1.3.6.1.4.1.4756.20.732.20.1.446 | Columnf2000EASPort1PeerOUIRemoteB | read-only | current | f2000EAS Series card Detailed Link OAM Status for Port 1: Peer: Organizational Unique Identification |
| 1.3.6.1.4.1.4756.20.732.20.1.447 | Columnf2000EASPort1PeerPDURevRemoteB | read-only | current | f2000EAS Series card Detailed Link OAM Status for Port 1: Peer: PDU Revision |
| 1.3.6.1.4.1.4756.20.732.20.1.448 | Columnf2000EASPort2PDUPermisionRemoteB | read-only | current | f2000EAS Series card Detailed Link OAM Status for Port 2: PDU Permission |
| 1.3.6.1.4.1.4756.20.732.20.1.449 | Columnf2000EASPort2DiscoveryStateRemoteB | read-only | current | f2000EAS Series card Detailed Link OAM Status for Port 2: Discovery State |
| 1.3.6.1.4.1.4756.20.732.20.1.450 | Columnf2000EASPort2PeerMACAddrRemoteB | read-only | current | f2000EAS Series card Detailed Link OAM Status for Port 2: Discovery State |
| 1.3.6.1.4.1.4756.20.732.20.1.451 | Columnf2000EASPort2LocalModeRemoteB | read-only | current | f2000EAS Series card Detailed Link OAM Status for Port 2: RemoteB: Mode |
| 1.3.6.1.4.1.4756.20.732.20.1.452 | Columnf2000EASPort2LocalUnOperationRemoteB | read-only | current | f2000EAS Series card Detailed Link OAM Status for Port 2: RemoteB: Unidirectional Operation Support |
| 1.3.6.1.4.1.4756.20.732.20.1.453 | Columnf2000EASPort2LocalRemoteLbRemoteB | read-only | current | f2000EAS Series card Detailed Link OAM Status for Port 2: RemoteB: Remote Loopback Support |
| 1.3.6.1.4.1.4756.20.732.20.1.454 | Columnf2000EASPort2LocalLMRemoteB | read-only | current | f2000EAS Series card Detailed Link OAM Status for Port 2: RemoteB: Link Monitoring Support |
| 1.3.6.1.4.1.4756.20.732.20.1.455 | Columnf2000EASPort2LocalMIBRetrievalRemoteB | read-only | current | f2000EAS Series card Detailed Link OAM Status for Port 2: RemoteB: MIB Retrieval Support |
| 1.3.6.1.4.1.4756.20.732.20.1.456 | Columnf2000EASPort2LocalMTUSizeRemoteB | read-only | current | f2000EAS Series card Detailed Link OAM Status for Port 2: RemoteB: MTU Size |
| 1.3.6.1.4.1.4756.20.732.20.1.457 | Columnf2000EASPort2LocalMultiStateRemoteB | read-only | current | f2000EAS Series card Detailed Link OAM Status for Port 2: RemoteB: Multiplexer State |
| 1.3.6.1.4.1.4756.20.732.20.1.458 | Columnf2000EASPort2LocalParserStateRemoteB | read-only | current | f2000EAS Series card Detailed Link OAM Status for Port 2: RemoteB: Multiplexer State |
| 1.3.6.1.4.1.4756.20.732.20.1.459 | Columnf2000EASPort2LocalOUIRemoteB | read-only | current | f2000EAS Series card Detailed Link OAM Status for Port 2: RemoteB: Organizational Unique Identification |
| 1.3.6.1.4.1.4756.20.732.20.1.460 | Columnf2000EASPort2LocalPDURevRemoteB | read-only | current | f2000EAS Series card Detailed Link OAM Status for Port 2: RemoteB: PDU Revision |
| 1.3.6.1.4.1.4756.20.732.20.1.461 | Columnf2000EASPort2PeerModeRemoteB | read-only | current | f2000EAS Series card Detailed Link OAM Status for Port 2: Peer: Mode |
| 1.3.6.1.4.1.4756.20.732.20.1.462 | Columnf2000EASPort2PeerUnOperationRemoteB | read-only | current | f2000EAS Series card Detailed Link OAM Status for Port 2: Peer: Unidirectional Operation Support |
| 1.3.6.1.4.1.4756.20.732.20.1.463 | Columnf2000EASPort2PeerRemoteLbRemoteB | read-only | current | f2000EAS Series card Detailed Link OAM Status for Port 2: Peer: Remote Loopback Support |
| 1.3.6.1.4.1.4756.20.732.20.1.464 | Columnf2000EASPort2PeerLMRemoteB | read-only | current | f2000EAS Series card Detailed Link OAM Status for Port 2: Peer: Link Monitoring Support |
| 1.3.6.1.4.1.4756.20.732.20.1.465 | Columnf2000EASPort2PeerMIBRetrievalRemoteB | read-only | current | f2000EAS Series card Detailed Link OAM Status for Port 2: Peer: MIB Retrieval Support |
| 1.3.6.1.4.1.4756.20.732.20.1.466 | Columnf2000EASPort2PeerMTUSizeRemoteB | read-only | current | f2000EAS Series card Detailed Link OAM Status for Port 2: Peer: MTU Size |
| 1.3.6.1.4.1.4756.20.732.20.1.467 | Columnf2000EASPort2PeerMultiStateRemoteB | read-only | current | f2000EAS Series card Detailed Link OAM Status for Port 2: Peer: Multiplexer State |
| 1.3.6.1.4.1.4756.20.732.20.1.468 | Columnf2000EASPort2PeerParserStateRemoteB | read-only | current | f2000EAS Series card Detailed Link OAM Status for Port 2: Peer: Multiplexer State |
| 1.3.6.1.4.1.4756.20.732.20.1.469 | Columnf2000EASPort2PeerOUIRemoteB | read-only | current | f2000EAS Series card Detailed Link OAM Status for Port 2: Peer: Organizational Unique Identification |
| 1.3.6.1.4.1.4756.20.732.20.1.470 | Columnf2000EASPort2PeerPDURevRemoteB | read-only | current | f2000EAS Series card Detailed Link OAM Status for Port 2: Peer: PDU Revision |
| 1.3.6.1.4.1.4756.20.732.20.1.471 | Columnf2000EASPort3PDUPermisionRemoteB | read-only | current | f2000EAS Series card Detailed Link OAM Status for Port 3: PDU Permission |
| 1.3.6.1.4.1.4756.20.732.20.1.472 | Columnf2000EASPort3DiscoveryStateRemoteB | read-only | current | f2000EAS Series card Detailed Link OAM Status for Port 3: Discovery State |
| 1.3.6.1.4.1.4756.20.732.20.1.473 | Columnf2000EASPort3PeerMACAddrRemoteB | read-only | current | f2000EAS Series card Detailed Link OAM Status for Port 3: Discovery State |
| 1.3.6.1.4.1.4756.20.732.20.1.474 | Columnf2000EASPort3LocalModeRemoteB | read-only | current | f2000EAS Series card Detailed Link OAM Status for Port 3: RemoteB: Mode |
| 1.3.6.1.4.1.4756.20.732.20.1.475 | Columnf2000EASPort3LocalUnOperationRemoteB | read-only | current | f2000EAS Series card Detailed Link OAM Status for Port 3: RemoteB: Unidirectional Operation Support |
| 1.3.6.1.4.1.4756.20.732.20.1.476 | Columnf2000EASPort3LocalRemoteLbRemoteB | read-only | current | f2000EAS Series card Detailed Link OAM Status for Port 3: RemoteB: Remote Loopback Support |
| 1.3.6.1.4.1.4756.20.732.20.1.477 | Columnf2000EASPort3LocalLMRemoteB | read-only | current | f2000EAS Series card Detailed Link OAM Status for Port 3: RemoteB: Link Monitoring Support |
| 1.3.6.1.4.1.4756.20.732.20.1.478 | Columnf2000EASPort3LocalMIBRetrievalRemoteB | read-only | current | f2000EAS Series card Detailed Link OAM Status for Port 3: RemoteB: MIB Retrieval Support |
| 1.3.6.1.4.1.4756.20.732.20.1.479 | Columnf2000EASPort3LocalMTUSizeRemoteB | read-only | current | f2000EAS Series card Detailed Link OAM Status for Port 3: RemoteB: MTU Size |
| 1.3.6.1.4.1.4756.20.732.20.1.480 | Columnf2000EASPort3LocalMultiStateRemoteB | read-only | current | f2000EAS Series card Detailed Link OAM Status for Port 3: RemoteB: Multiplexer State |
| 1.3.6.1.4.1.4756.20.732.20.1.481 | Columnf2000EASPort3LocalParserStateRemoteB | read-only | current | f2000EAS Series card Detailed Link OAM Status for Port 3: RemoteB: Multiplexer State |
| 1.3.6.1.4.1.4756.20.732.20.1.482 | Columnf2000EASPort3LocalOUIRemoteB | read-only | current | f2000EAS Series card Detailed Link OAM Status for Port 3: RemoteB: Organizational Unique Identification |
| 1.3.6.1.4.1.4756.20.732.20.1.483 | Columnf2000EASPort3LocalPDURevRemoteB | read-only | current | f2000EAS Series card Detailed Link OAM Status for Port 3: RemoteB: PDU Revision |
| 1.3.6.1.4.1.4756.20.732.20.1.484 | Columnf2000EASPort3PeerModeRemoteB | read-only | current | f2000EAS Series card Detailed Link OAM Status for Port 3: Peer: Mode |
| 1.3.6.1.4.1.4756.20.732.20.1.485 | Columnf2000EASPort3PeerUnOperationRemoteB | read-only | current | f2000EAS Series card Detailed Link OAM Status for Port 3: Peer: Unidirectional Operation Support |
| 1.3.6.1.4.1.4756.20.732.20.1.486 | Columnf2000EASPort3PeerRemoteLbRemoteB | read-only | current | f2000EAS Series card Detailed Link OAM Status for Port 3: Peer: Remote Loopback Support |
| 1.3.6.1.4.1.4756.20.732.20.1.487 | Columnf2000EASPort3PeerLMRemoteB | read-only | current | f2000EAS Series card Detailed Link OAM Status for Port 3: Peer: Link Monitoring Support |
| 1.3.6.1.4.1.4756.20.732.20.1.488 | Columnf2000EASPort3PeerMIBRetrievalRemoteB | read-only | current | f2000EAS Series card Detailed Link OAM Status for Port 3: Peer: MIB Retrieval Support |
| 1.3.6.1.4.1.4756.20.732.20.1.489 | Columnf2000EASPort3PeerMTUSizeRemoteB | read-only | current | f2000EAS Series card Detailed Link OAM Status for Port 3: Peer: MTU Size |
| 1.3.6.1.4.1.4756.20.732.20.1.490 | Columnf2000EASPort3PeerMultiStateRemoteB | read-only | current | f2000EAS Series card Detailed Link OAM Status for Port 3: Peer: Multiplexer State |
| 1.3.6.1.4.1.4756.20.732.20.1.491 | Columnf2000EASPort3PeerParserStateRemoteB | read-only | current | f2000EAS Series card Detailed Link OAM Status for Port 3: Peer: Multiplexer State |
| 1.3.6.1.4.1.4756.20.732.20.1.492 | Columnf2000EASPort3PeerOUIRemoteB | read-only | current | f2000EAS Series card Detailed Link OAM Status for Port 3: Peer: Organizational Unique Identification |
| 1.3.6.1.4.1.4756.20.732.20.1.493 | Columnf2000EASPort3PeerPDURevRemoteB | read-only | current | f2000EAS Series card Detailed Link OAM Status for Port 3: Peer: PDU Revision |
| 1.3.6.1.4.1.4756.20.732.20.1.494 | Columnf2000EASPort4PDUPermisionRemoteB | read-only | current | f2000EAS Series card Detailed Link OAM Status for Port 4: PDU Permission |
| 1.3.6.1.4.1.4756.20.732.20.1.495 | Columnf2000EASPort4DiscoveryStateRemoteB | read-only | current | f2000EAS Series card Detailed Link OAM Status for Port 4: Discovery State |
| 1.3.6.1.4.1.4756.20.732.20.1.496 | Columnf2000EASPort4PeerMACAddrRemoteB | read-only | current | f2000EAS Series card Detailed Link OAM Status for Port 4: Discovery State |
| 1.3.6.1.4.1.4756.20.732.20.1.497 | Columnf2000EASPort4LocalModeRemoteB | read-only | current | f2000EAS Series card Detailed Link OAM Status for Port 4: RemoteB: Mode |
| 1.3.6.1.4.1.4756.20.732.20.1.498 | Columnf2000EASPort4LocalUnOperationRemoteB | read-only | current | f2000EAS Series card Detailed Link OAM Status for Port 4: RemoteB: Unidirectional Operation Support |
| 1.3.6.1.4.1.4756.20.732.20.1.499 | Columnf2000EASPort4LocalRemoteLbRemoteB | read-only | current | f2000EAS Series card Detailed Link OAM Status for Port 4: RemoteB: Remote Loopback Support |
| 1.3.6.1.4.1.4756.20.732.20.1.500 | Columnf2000EASPort4LocalLMRemoteB | read-only | current | f2000EAS Series card Detailed Link OAM Status for Port 4: RemoteB: Link Monitoring Support |
| 1.3.6.1.4.1.4756.20.732.20.1.501 | Columnf2000EASPort4LocalMIBRetrievalRemoteB | read-only | current | f2000EAS Series card Detailed Link OAM Status for Port 4: RemoteB: MIB Retrieval Support |
| 1.3.6.1.4.1.4756.20.732.20.1.502 | Columnf2000EASPort4LocalMTUSizeRemoteB | read-only | current | f2000EAS Series card Detailed Link OAM Status for Port 4: RemoteB: MTU Size |
| 1.3.6.1.4.1.4756.20.732.20.1.503 | Columnf2000EASPort4LocalMultiStateRemoteB | read-only | current | f2000EAS Series card Detailed Link OAM Status for Port 4: RemoteB: Multiplexer State |
| 1.3.6.1.4.1.4756.20.732.20.1.504 | Columnf2000EASPort4LocalParserStateRemoteB | read-only | current | f2000EAS Series card Detailed Link OAM Status for Port 4: RemoteB: Multiplexer State |
| 1.3.6.1.4.1.4756.20.732.20.1.505 | Columnf2000EASPort4LocalOUIRemoteB | read-only | current | f2000EAS Series card Detailed Link OAM Status for Port 4: RemoteB: Organizational Unique Identification |
| 1.3.6.1.4.1.4756.20.732.20.1.506 | Columnf2000EASPort4LocalPDURevRemoteB | read-only | current | f2000EAS Series card Detailed Link OAM Status for Port 4: RemoteB: PDU Revision |
| 1.3.6.1.4.1.4756.20.732.20.1.507 | Columnf2000EASPort4PeerModeRemoteB | read-only | current | f2000EAS Series card Detailed Link OAM Status for Port 4: Peer: Mode |
| 1.3.6.1.4.1.4756.20.732.20.1.508 | Columnf2000EASPort4PeerUnOperationRemoteB | read-only | current | f2000EAS Series card Detailed Link OAM Status for Port 4: Peer: Unidirectional Operation Support |
| 1.3.6.1.4.1.4756.20.732.20.1.509 | Columnf2000EASPort4PeerRemoteLbRemoteB | read-only | current | f2000EAS Series card Detailed Link OAM Status for Port 4: Peer: Remote Loopback Support |
| 1.3.6.1.4.1.4756.20.732.20.1.510 | Columnf2000EASPort4PeerLMRemoteB | read-only | current | f2000EAS Series card Detailed Link OAM Status for Port 4: Peer: Link Monitoring Support |
| 1.3.6.1.4.1.4756.20.732.20.1.511 | Columnf2000EASPort4PeerMIBRetrievalRemoteB | read-only | current | f2000EAS Series card Detailed Link OAM Status for Port 4: Peer: MIB Retrieval Support |
| 1.3.6.1.4.1.4756.20.732.20.1.512 | Columnf2000EASPort4PeerMTUSizeRemoteB | read-only | current | EDD Series card Detailed Link OAM Status for Port 4: Peer: MTU Size |
| 1.3.6.1.4.1.4756.20.732.20.1.513 | Columnf2000EASPort4PeerMultiStateRemoteB | read-only | current | f2000EAS Series card Detailed Link OAM Status for Port 4: Peer: Multiplexer State |
| 1.3.6.1.4.1.4756.20.732.20.1.514 | Columnf2000EASPort4PeerParserStateRemoteB | read-only | current | f2000EAS Series card Detailed Link OAM Status for Port 4: Peer: Multiplexer State |
| 1.3.6.1.4.1.4756.20.732.20.1.515 | Columnf2000EASPort4PeerOUIRemoteB | read-only | current | f2000EAS Series card Detailed Link OAM Status for Port 4: Peer: Organizational Unique Identification |
| 1.3.6.1.4.1.4756.20.732.20.1.516 | Columnf2000EASPort4PeerPDURevRemoteB | read-only | current | f2000EAS Series card Detailed Link OAM Status for Port 4: Peer: PDU Revision |
| 1.3.6.1.4.1.4756.20.732.20.1.517 | Columnf2000EASCLEAROAMCOUNTERRemoteB | read-write | current | f2000EAS Series card Clear OAM Counter: 0: Off 1: Action |
| 1.3.6.1.4.1.4756.20.732.20.1.518 | Columnf2000EASLoopProtectionEnableRemoteB | read-write | current | f2000EAS Series card Loop Protection Configuration: General Settings - Enable Loop Protection 0: Disable 1: Enable |
| 1.3.6.1.4.1.4756.20.732.20.1.519 | Columnf2000EASLoopProtectionTxTimeRemoteB | read-write | current | f2000EAS Series card Loop Protection Configuration: General Settings - Transmission Time |
| 1.3.6.1.4.1.4756.20.732.20.1.520 | Columnf2000EASLoopProtectionShutdownTimeRemoteB | read-write | current | f2000EAS Series card Loop Protection Configuration: General Settings - Shutdown Time |
| 1.3.6.1.4.1.4756.20.732.20.1.521 | Columnf2000EASLoopProtectionPort1EnabledRemoteB | read-write | current | f2000EAS Series card Loop Protection Configuration for Port 1: Port Configuration - Enable 0: Disable 1: Enable |
| 1.3.6.1.4.1.4756.20.732.20.1.522 | Columnf2000EASLoopProtectionPort1ActionRemoteB | read-write | current | f2000EAS Series card Loop Protection Configuration for Port 1: Port Configuration - Action 0: Shutdown Port 1: Shutdown Port And Log 2: Log Only |
| 1.3.6.1.4.1.4756.20.732.20.1.523 | Columnf2000EASLoopProtectionPort1TxModeRemoteB | read-write | current | f2000EAS Series card Loop Protection Configuration for Port 1: Port Configuration - Tx Mode 0: Disable 1: Enable |
| 1.3.6.1.4.1.4756.20.732.20.1.524 | Columnf2000EASLoopProtectionPort2EnabledRemoteB | read-write | current | f2000EAS Series card Loop Protection Configuration for Port 2: Port Configuration - Enable 0: Disable 1: Enable |
| 1.3.6.1.4.1.4756.20.732.20.1.525 | Columnf2000EASLoopProtectionPort2ActionRemoteB | read-write | current | f2000EAS Series card Loop Protection Configuration for Port 2: Port Configuration - Action 0: Shutdown Port 1: Shutdown Port And Log 2: Log Only |
| 1.3.6.1.4.1.4756.20.732.20.1.526 | Columnf2000EASLoopProtectionPort2TxModeRemoteB | read-write | current | f2000EAS Series card Loop Protection Configuration for Port 2: Port Configuration - Tx Mode 0: Disable 1: Enable |
| 1.3.6.1.4.1.4756.20.732.20.1.527 | Columnf2000EASLoopProtectionPort3EnabledRemoteB | read-write | current | f2000EASE Series card Loop Protection Configuration for Port 3: Port Configuration - Enable 0: Disable 1: Enable |
| 1.3.6.1.4.1.4756.20.732.20.1.528 | Columnf2000EASLoopProtectionPort3ActionRemoteB | read-write | current | f2000EAS Series card Loop Protection Configuration for Port 3: Port Configuration - Action 0: Shutdown Port 1: Shutdown Port And Log 2: Log Only |
| 1.3.6.1.4.1.4756.20.732.20.1.529 | Columnf2000EASLoopProtectionPort3TxModeRemoteB | read-write | current | f2000EAS Series card Loop Protection Configuration for Port 3: Port Configuration - Tx Mode 0: Disable 1: Enable |
| 1.3.6.1.4.1.4756.20.732.20.1.530 | Columnf2000EASLoopProtectionPort4EnabledRemoteB | read-write | current | f2000EAS Series card Loop Protection Configuration for Port 4: Port Configuration - Enable 0: Disable 1: Enable |
| 1.3.6.1.4.1.4756.20.732.20.1.531 | Columnf2000EASLoopProtectionPort4ActionRemoteB | read-write | current | f2000EAS Series card Loop Protection Configuration for Port 4: Port Configuration - Action 0: Shutdown Port 1: Shutdown Port And Log 2: Log Only |
| 1.3.6.1.4.1.4756.20.732.20.1.532 | Columnf2000EASLoopProtectionPort4TxModeRemoteB | read-write | current | f2000EAS Series card Loop Protection Configuration for Port 41: Port Configuration - Tx Mode 0: Disable 1: Enable |
| 1.3.6.1.4.1.4756.20.732.20.1.533 | Columnf2000EASLoopProtectionPort1ActionStsRemoteB | read-only | current | f2000EAS Series card Loop Protection Status for Port 1: Action |
| 1.3.6.1.4.1.4756.20.732.20.1.534 | Columnf2000EASLoopProtectionPort1TransStsRemoteB | read-only | current | f2000EAS Series card Loop Protection Status for Port 1: Transmit |
| 1.3.6.1.4.1.4756.20.732.20.1.535 | Columnf2000EASLoopProtectionPort1LoopsStsRemoteB | read-only | current | f2000EAS Series card Loop Protection Status for Port 1: Loops |
| 1.3.6.1.4.1.4756.20.732.20.1.536 | Columnf2000EASLoopProtectionPort1StatusRemoteB | read-only | current | f2000EAS Series card Loop Protection Status for Port 1: Status |
| 1.3.6.1.4.1.4756.20.732.20.1.537 | Columnf2000EASLoopProtectionPort1LoopStsRemoteB | read-only | current | f2000EAS Series card Loop Protection Status for Port 1: Loop |
| 1.3.6.1.4.1.4756.20.732.20.1.538 | Columnf2000EASLoopProtectionPort2ActionStsRemoteB | read-only | current | f2000EAS Series card Loop Protection Status for Port 2: Action |
| 1.3.6.1.4.1.4756.20.732.20.1.539 | Columnf2000EASLoopProtectionPort2TransStsRemoteB | read-only | current | f2000EAS Series card Loop Protection Status for Port 2: Transmit |
| 1.3.6.1.4.1.4756.20.732.20.1.540 | Columnf2000EASLoopProtectionPort2LoopsStsRemoteB | read-only | current | f2000EAS Series card Loop Protection Status for Port 2: Loops |
| 1.3.6.1.4.1.4756.20.732.20.1.541 | Columnf2000EASLoopProtectionPort2StatusRemoteB | read-only | current | f2000EAS Series card Loop Protection Status for Port 2: Status |
| 1.3.6.1.4.1.4756.20.732.20.1.542 | Columnf2000EASLoopProtectionPort2LoopStsRemoteB | read-only | current | f2000EAS Series card Loop Protection Status for Port 2: Loop |
| 1.3.6.1.4.1.4756.20.732.20.1.543 | Columnf2000EASLoopProtectionPort3ActionStsRemoteB | read-only | current | f2000EAS Series card Loop Protection Status for Port 3: Action |
| 1.3.6.1.4.1.4756.20.732.20.1.544 | Columnf2000EASLoopProtectionPort3TransStsRemoteB | read-only | current | f2000EAS Series card Loop Protection Status for Port 3: Transmit |
| 1.3.6.1.4.1.4756.20.732.20.1.545 | Columnf2000EASLoopProtectionPort3LoopsStsRemoteB | read-only | current | f2000EAS Series card Loop Protection Status for Port 3: Loops |
| 1.3.6.1.4.1.4756.20.732.20.1.546 | Columnf2000EASLoopProtectionPort3StatusRemoteB | read-only | current | f2000EAS Series card Loop Protection Status for Port 3: Status |
| 1.3.6.1.4.1.4756.20.732.20.1.547 | Columnf2000EASLoopProtectionPort3LoopStsRemoteB | read-only | current | f2000EAS Series card Loop Protection Status for Port 3: Loop |
| 1.3.6.1.4.1.4756.20.732.20.1.548 | Columnf2000EASLoopProtectionPort4ActionStsRemoteB | read-only | current | f2000EAS Series card Loop Protection Status for Port 4: Action |
| 1.3.6.1.4.1.4756.20.732.20.1.549 | Columnf2000EASLoopProtectionPort4TransStsRemoteB | read-only | current | f2000EAS Series card Loop Protection Status for Port 4: Transmit |
| 1.3.6.1.4.1.4756.20.732.20.1.550 | Columnf2000EASLoopProtectionPort4LoopsStsRemoteB | read-only | current | f2000EAS Series card Loop Protection Status for Port 4: Loops |
| 1.3.6.1.4.1.4756.20.732.20.1.551 | Columnf2000EASLoopProtectionPort4StatusRemoteB | read-only | current | f2000EAS Series card Loop Protection Status for Port 4: Status |
| 1.3.6.1.4.1.4756.20.732.20.1.552 | Columnf2000EASLoopProtectionPort4LoopStsRemoteB | read-only | current | f2000EAS Series card Loop Protection Status for Port 4: Loop |
| 1.3.6.1.4.1.4756.20.732.20.1.553 | Columnf2000EASSTPProtocolVersionRemoteB | read-write | current | f2000EAS Series card STP Bridge Configuration: Basic Settings - Protocol Version 0: STP 1: RSTP 2: MSTP |
| 1.3.6.1.4.1.4756.20.732.20.1.554 | Columnf2000EASSTPBridgePriorityRemoteB | read-write | current | f2000EAS Series card STP Bridge Configuration: Basic Settings - Bridge Priority 0: 0 1: 4096 2: 8192 3: 12288 4: 16384 5: 20480 6: 24576 7: 28672 8: 32768 9: 3… |
| 1.3.6.1.4.1.4756.20.732.20.1.555 | Columnf2000EASSTPForwardDelayRemoteB | read-write | current | f2000EAS Series card STP Bridge Configuration: Basic Settings - Forward Delay |
| 1.3.6.1.4.1.4756.20.732.20.1.556 | Columnf2000EASSTPMaxAgeRemoteB | read-write | current | f2000EAS Series card STP Bridge Configuration: Basic Settings - Max Age |
| 1.3.6.1.4.1.4756.20.732.20.1.557 | Columnf2000EASSTPMaximumHopCountRemoteB | read-write | current | f2000EAS Series card STP Bridge Configuration: Basic Settings - Maximum Hop Count |
| 1.3.6.1.4.1.4756.20.732.20.1.558 | Columnf2000EASSTPTransmitHoldCountRemoteB | read-write | current | f2000EAS Series card STP Bridge Configuration: Basic Settings - Transmit Hold Count |
| 1.3.6.1.4.1.4756.20.732.20.1.559 | Columnf2000EASSTPEdgePortBPDUFilteringRemoteB | read-write | current | f2000EAS Series card STP Bridge Configuration: Advanced Settings - Edge Port BPDU Filtering 0: Off 1: On |
| 1.3.6.1.4.1.4756.20.732.20.1.560 | Columnf2000EASSTPEdgePortBPDUGuardRemoteB | read-write | current | f2000EAS Series card STP Bridge Configuration: Advanced Settings - Edge Port BPDU Guard 0: Off 1: On |
| 1.3.6.1.4.1.4756.20.732.20.1.561 | Columnf2000EASSTPPortErrorRecoveryTimeoutRemoteB | read-write | current | f2000EAS Series card STP Bridge Configuration: Advanced Settings - Port Error Recovery Timeout 0: Off 1: On |
| 1.3.6.1.4.1.4756.20.732.20.1.562 | Columnf2000EASMSTIConfigurationNameRemoteB | read-write | current | f2000EAS Series card MSTI Configuration: Configuration Identification - Configuration Name |
| 1.3.6.1.4.1.4756.20.732.20.1.563 | Columnf2000EASMSTIConfigurationRevisionRemoteB | read-write | current | f2000EAS Series card MSTI Configuration: Configuration Identification - Configuration Revision |
| 1.3.6.1.4.1.4756.20.732.20.1.564 | Columnf2000EASMSTI1VLANsMappingRemoteB | read-write | current | f2000EAS Series card MSTI Configuration: MSTI Mapping - MSTI 1 |
| 1.3.6.1.4.1.4756.20.732.20.1.565 | Columnf2000EASMSTI2VLANsMappingRemoteB | read-write | current | f2000EAS Series card MSTI Configuration: MSTI Mapping - MSTI 2 |
| 1.3.6.1.4.1.4756.20.732.20.1.566 | Columnf2000EASMSTI3VLANsMappingRemoteB | read-write | current | f2000EAS Series card MSTI Configuration: MSTI Mapping - MSTI 3 |
| 1.3.6.1.4.1.4756.20.732.20.1.567 | Columnf2000EASMSTI4VLANsMappingRemoteB | read-write | current | f2000EAS Series card MSTI Configuration: MSTI Mapping - MSTI 4 |
| 1.3.6.1.4.1.4756.20.732.20.1.568 | Columnf2000EASMSTI5VLANsMappingRemoteB | read-write | current | f2000EAS Series card MSTI Configuration: MSTI Mapping - MSTI 5 |
| 1.3.6.1.4.1.4756.20.732.20.1.569 | Columnf2000EASMSTI6VLANsMappingRemoteB | read-write | current | f2000EAS Series card MSTI Configuration: MSTI Mapping - MSTI 6 |
| 1.3.6.1.4.1.4756.20.732.20.1.570 | Columnf2000EASMSTI7VLANsMappingRemoteB | read-write | current | f2000EAS Series card MSTI Configuration: MSTI Mapping - MSTI 7 |
| 1.3.6.1.4.1.4756.20.732.20.1.571 | Columnf2000EASCISTAggregatedSTPEnabledRemoteB | read-write | current | f2000EAS Series card STP CIST Port Configuration: CIST Aggregated Port Configuration - STP Enabled |
| 1.3.6.1.4.1.4756.20.732.20.1.572 | Columnf2000EASCISTAggregatedPathCostRemoteB | read-write | current | f2000EAS Series card STP CIST Port Configuration: CIST Aggregated Port Configuration - Path Cost Valid values are in the range 0 to 200000000. Setting 0 means … |
| 1.3.6.1.4.1.4756.20.732.20.1.573 | Columnf2000EASCISTAggregatedPriorityRemoteB | read-write | current | f2000EAS Series card STP CIST Port Configuration: CIST Aggregated Port Configuration - Priority |
| 1.3.6.1.4.1.4756.20.732.20.1.574 | Columnf2000EASCISTAggregatedAdminEdgeRemoteB | read-write | current | f2000EAS Series card STP CIST Port Configuration: CIST Aggregated Port Configuration - STP Enabled 0: Non-edge 1: Edge |
| 1.3.6.1.4.1.4756.20.732.20.1.575 | Columnf2000EASCISTAggregatedAutoEdgeRemoteB | read-write | current | f2000EAS Series card STP CIST Port Configuration: CIST Aggregated Port Configuration - Auto Edge 0: Non-edge 1: Edge |
| 1.3.6.1.4.1.4756.20.732.20.1.576 | Columnf2000EASCISTAggregatedRestrictedRoleRemoteB | read-write | current | f2000EAS Series card STP CIST Port Configuration: CIST Aggregated Port Configuration - Restricted Role 0: Non-edge 1: Edge |
| 1.3.6.1.4.1.4756.20.732.20.1.577 | Columnf2000EASCISTAggregatedRestrictedTCNRemoteB | read-write | current | f2000EAS Series card STP CIST Port Configuration: CIST Aggregated Port Configuration - Restricted TCN 0: Non-edge 1: Edge |
| 1.3.6.1.4.1.4756.20.732.20.1.578 | Columnf2000EASCISTAggregatedBPDUGuardRemoteB | read-write | current | f2000EAS Series card STP CIST Port Configuration: CIST Aggregated Port Configuration - BPDU Guard 0: Non-edge 1: Edge |
| 1.3.6.1.4.1.4756.20.732.20.1.579 | Columnf2000EASCISTAggregatedPointToPointRemoteB | read-write | current | f2000EAS Series card STP CIST Port Configuration: CIST Aggregated Port Configuration - Point-to-point 0: Forced True 1: Forced False 2: Auto |
| 1.3.6.1.4.1.4756.20.732.20.1.580 | Columnf2000EASCISTPort1STPEnabledRemoteB | read-write | current | f2000EAS Series card STP CIST Port Configuration: CIST Normal Port1 Configuration - STP Enabled |
| 1.3.6.1.4.1.4756.20.732.20.1.581 | Columnf2000EASCISTPort1PathCostRemoteB | read-write | current | f2000EAS Series card STP CIST Port Configuration: CIST Normal Port1 Configuration - Path Cost Valid values are in the range 0 to 200000000. Setting 0 means Aut… |
| 1.3.6.1.4.1.4756.20.732.20.1.582 | Columnf2000EASCISTPort1PriorityRemoteB | read-write | current | f2000EAS Series card STP CIST Port Configuration: CIST Normal Port1 Configuration - Priority |
| 1.3.6.1.4.1.4756.20.732.20.1.583 | Columnf2000EASCISTPort1AdminEdgeRemoteB | read-write | current | f2000EAS Series card STP CIST Port Configuration: CIST Normal Port1 Configuration - STP Enabled 0: Non-edge 1: Edge |
| 1.3.6.1.4.1.4756.20.732.20.1.584 | Columnf2000EASCISTPort1AutoEdgeRemoteB | read-write | current | f2000EAS Series card STP CIST Port Configuration: CIST Normal Port1 Configuration - Auto Edge 0: Non-edge 1: Edge |
| 1.3.6.1.4.1.4756.20.732.20.1.585 | Columnf2000EASCISTPort1RestrictedRoleRemoteB | read-write | current | f2000EAS Series card STP CIST Port Configuration: CIST Normal Port1 Configuration - Restricted Role 0: Non-edge 1: Edge |
| 1.3.6.1.4.1.4756.20.732.20.1.586 | Columnf2000EASCISTPort1RestrictedTCNRemoteB | read-write | current | f2000EAS Series card STP CIST Port Configuration: CIST Normal Port1 Configuration - Restricted TCN 0: Non-edge 1: Edge |
| 1.3.6.1.4.1.4756.20.732.20.1.587 | Columnf2000EASCISTPort1BPDUGuardRemoteB | read-write | current | f2000EAS Series card STP CIST Port Configuration: CIST Normal Port1 Configuration - BPDU Guard 0: Non-edge 1: Edge |
| 1.3.6.1.4.1.4756.20.732.20.1.588 | Columnf2000EASCISTPort1PointToPointRemoteB | read-write | current | f2000EAS Series card STP CIST Port Configuration: CIST Normal Port1 Configuration - Point-to-point 0: Forced True 1: Forced False 2: Auto |
| 1.3.6.1.4.1.4756.20.732.20.1.589 | Columnf2000EASCISTPort2STPEnabledRemoteB | read-write | current | f2000EAS Series card STP CIST Port Configuration: CIST Normal Port2 Configuration - STP Enabled |
| 1.3.6.1.4.1.4756.20.732.20.1.590 | Columnf2000EASCISTPort2PathCostRemoteB | read-write | current | f2000EAS Series card STP CIST Port Configuration: CIST Normal Port2 Configuration - Path Cost Valid values are in the range 0 to 200000000. Setting 0 means Aut… |
| 1.3.6.1.4.1.4756.20.732.20.1.591 | Columnf2000EASCISTPort2PriorityRemoteB | read-write | current | f2000EAS Series card STP CIST Port Configuration: CIST Normal Port2 Configuration - Priority |
| 1.3.6.1.4.1.4756.20.732.20.1.592 | Columnf2000EASCISTPort2AdminEdgeRemoteB | read-write | current | f2000EAS Series card STP CIST Port Configuration: CIST Normal Port2 Configuration - STP Enabled 0: Non-edge 1: Edge |
| 1.3.6.1.4.1.4756.20.732.20.1.593 | Columnf2000EASCISTPort2AutoEdgeRemoteB | read-write | current | f2000EAS Series card STP CIST Port Configuration: CIST Normal Port2 Configuration - Auto Edge 0: Non-edge 1: Edge |
| 1.3.6.1.4.1.4756.20.732.20.1.594 | Columnf2000EASCISTPort2RestrictedRoleRemoteB | read-write | current | f2000EAS Series card STP CIST Port Configuration: CIST Normal Port2 Configuration - Restricted Role 0: Non-edge 1: Edge |
| 1.3.6.1.4.1.4756.20.732.20.1.595 | Columnf2000EASCISTPort2RestrictedTCNRemoteB | read-write | current | f2000EAS Series card STP CIST Port Configuration: CIST Normal Port2 Configuration - Restricted TCN 0: Non-edge 1: Edge |
| 1.3.6.1.4.1.4756.20.732.20.1.596 | Columnf2000EASCISTPort2BPDUGuardRemoteB | read-write | current | f2000EAS Series card STP CIST Port Configuration: CIST Normal Port2 Configuration - BPDU Guard 0: Non-edge 1: Edge |
| 1.3.6.1.4.1.4756.20.732.20.1.597 | Columnf2000EASCISTPort2PointToPointRemoteB | read-write | current | f2000EAS Series card STP CIST Port Configuration: CIST Normal Port2 Configuration - Point-to-point 0: Forced True 1: Forced False 2: Auto |
| 1.3.6.1.4.1.4756.20.732.20.1.598 | Columnf2000EASCISTPort3STPEnabledRemoteB | read-write | current | f2000EAS Series card STP CIST Port Configuration: CIST Normal Port3 Configuration - STP Enabled |
| 1.3.6.1.4.1.4756.20.732.20.1.599 | Columnf2000EASCISTPort3PathCostRemoteB | read-write | current | f2000EAS Series card STP CIST Port Configuration: CIST Normal Port3 Configuration - Path Cost Valid values are in the range 0 to 200000000. Setting 0 means Aut… |
| 1.3.6.1.4.1.4756.20.732.20.1.600 | Columnf2000EASCISTPort3PriorityRemoteB | read-write | current | f2000EAS Series card STP CIST Port Configuration: CIST Normal Port3 Configuration - Priority |
| 1.3.6.1.4.1.4756.20.732.20.1.601 | Columnf2000EASCISTPort3AdminEdgeRemoteB | read-write | current | f2000EAS Series card STP CIST Port Configuration: CIST Normal Port3 Configuration - STP Enabled 0: Non-edge 1: Edge |
| 1.3.6.1.4.1.4756.20.732.20.1.602 | Columnf2000EASCISTPort3AutoEdgeRemoteB | read-write | current | f2000EAS Series card STP CIST Port Configuration: CIST Normal Port3 Configuration - Auto Edge 0: Non-edge 1: Edge |
| 1.3.6.1.4.1.4756.20.732.20.1.603 | Columnf2000EASCISTPort3RestrictedRoleRemoteB | read-write | current | f2000EAS Series card STP CIST Port Configuration: CIST Normal Port3 Configuration - Restricted Role 0: Non-edge 1: Edge |
| 1.3.6.1.4.1.4756.20.732.20.1.604 | Columnf2000EASCISTPort3RestrictedTCNRemoteB | read-write | current | f2000EAS Series card STP CIST Port Configuration: CIST Normal Port3 Configuration - Restricted TCN 0: Non-edge 1: Edge |
| 1.3.6.1.4.1.4756.20.732.20.1.605 | Columnf2000EASCISTPort3BPDUGuardRemoteB | read-write | current | f2000EAS Series card STP CIST Port Configuration: CIST Normal Port3 Configuration - BPDU Guard 0: Non-edge 1: Edge |
| 1.3.6.1.4.1.4756.20.732.20.1.606 | Columnf2000EASCISTPort3PointToPointRemoteB | read-write | current | f2000EAS Series card STP CIST Port Configuration: CIST Normal Port3 Configuration - Point-to-point 0: Forced True 1: Forced False 2: Auto |
| 1.3.6.1.4.1.4756.20.732.20.1.607 | Columnf2000EASCISTPort4STPEnabledRemoteB | read-write | current | f2000EAS Series card STP CIST Port Configuration: CIST Normal Port4 Configuration - STP Enabled |
| 1.3.6.1.4.1.4756.20.732.20.1.608 | Columnf2000EASCISTPort4PathCostRemoteB | read-write | current | f2000EAS Series card STP CIST Port Configuration: CIST Normal Port4 Configuration - Path Cost Valid values are in the range 0 to 200000000. Setting 0 means Aut… |
| 1.3.6.1.4.1.4756.20.732.20.1.609 | Columnf2000EASCISTPort4PriorityRemoteB | read-write | current | f2000EAS Series card STP CIST Port Configuration: CIST Normal Port4 Configuration - Priority |
| 1.3.6.1.4.1.4756.20.732.20.1.610 | Columnf2000EASCISTPort4AdminEdgeRemoteB | read-write | current | f2000EAS Series card STP CIST Port Configuration: CIST Normal Port4 Configuration - STP Enabled 0: Non-edge 1: Edge |
| 1.3.6.1.4.1.4756.20.732.20.1.611 | Columnf2000EASCISTPort4AutoEdgeRemoteB | read-write | current | f2000EAS Series card STP CIST Port Configuration: CIST Normal Port4 Configuration - Auto Edge 0: Non-edge 1: Edge |
| 1.3.6.1.4.1.4756.20.732.20.1.612 | Columnf2000EASCISTPort4RestrictedRoleRemoteB | read-write | current | f2000EAS Series card STP CIST Port Configuration: CIST Normal Port4 Configuration - Restricted Role 0: Non-edge 1: Edge |
| 1.3.6.1.4.1.4756.20.732.20.1.613 | Columnf2000EASCISTPort4RestrictedTCNRemoteB | read-write | current | f2000EAS Series card STP CIST Port Configuration: CIST Normal Port4 Configuration - Restricted TCN 0: Non-edge 1: Edge |
| 1.3.6.1.4.1.4756.20.732.20.1.614 | Columnf2000EASCISTPort4BPDUGuardRemoteB | read-write | current | f2000EAS Series card STP CIST Port Configuration: CIST Normal Port4 Configuration - BPDU Guard 0: Non-edge 1: Edge |
| 1.3.6.1.4.1.4756.20.732.20.1.615 | Columnf2000EASCISTPort4PointToPointRemoteB | read-write | current | f2000EAS Series card STP CIST Port Configuration: CIST Normal Port4 Configuration - Point-to-point 0: Forced True 1: Forced False 2: Auto |
| 1.3.6.1.4.1.4756.20.732.20.1.616 | Columnf2000EASMSTI1AggregatedPathCostRemoteB | read-write | current | f2000EAS Series card MSTI Port Configuration: MSTI1 Aggregated Ports Configuration - Path Cost Valid values are in the range 0 to 200000000. Setting 0 means Au… |
| 1.3.6.1.4.1.4756.20.732.20.1.617 | Columnf2000EASMSTI1AggregatedPriorityRemoteB | read-write | current | f2000EAS Series card MSTI Port Configuration: MSTI1 Aggregated Ports Configuration - Priority |
| 1.3.6.1.4.1.4756.20.732.20.1.618 | Columnf2000EASMSTI1Port1PathCostRemoteB | read-write | current | f2000EAS Series card MSTI Port Configuration: MSTI1 Normal Port1 Configuration - Path Cost Valid values are in the range 0 to 200000000. Setting 0 means Auto p… |
| 1.3.6.1.4.1.4756.20.732.20.1.619 | Columnf2000EASMSTI1Port1PriorityRemoteB | read-write | current | f2000EAS Series card MSTI Port Configuration: MSTI1 Normal Port1 Configuration - Priority |
| 1.3.6.1.4.1.4756.20.732.20.1.620 | Columnf2000EASMSTI1Port2PathCostRemoteB | read-write | current | f2000EAS Series card MSTI Port Configuration: MSTI1 Normal Port2 Configuration - Path Cost Valid values are in the range 0 to 200000000. Setting 0 means Auto p… |
| 1.3.6.1.4.1.4756.20.732.20.1.621 | Columnf2000EASMSTI1Port2PriorityRemoteB | read-write | current | f2000EAS Series card MSTI Port Configuration: MSTI1 Normal Port2 Configuration - Priority |
| 1.3.6.1.4.1.4756.20.732.20.1.622 | Columnf2000EASMSTI1Port3PathCostRemoteB | read-write | current | f2000EAS Series card MSTI Port Configuration: MSTI1 Normal Port3 Configuration - Path Cost Valid values are in the range 0 to 200000000. Setting 0 means Auto p… |
| 1.3.6.1.4.1.4756.20.732.20.1.623 | Columnf2000EASMSTI1Port3PriorityRemoteB | read-write | current | f2000EAS Series card MSTI Port Configuration: MSTI1 Normal Port3 Configuration - Priority |
| 1.3.6.1.4.1.4756.20.732.20.1.624 | Columnf2000EASMSTI1Port4PathCostRemoteB | read-write | current | f2000EAS Series card MSTI Port Configuration: MSTI1 Normal Port4 Configuration - Path Cost Valid values are in the range 0 to 200000000. Setting 0 means Auto p… |
| 1.3.6.1.4.1.4756.20.732.20.1.625 | Columnf2000EASMSTI1Port4PriorityRemoteB | read-write | current | f2000EAS Series card MSTI Port Configuration: MSTI1 Normal Port4 Configuration - Priority |
| 1.3.6.1.4.1.4756.20.732.20.1.626 | Columnf2000EASMSTI2AggregatedPathCostRemoteB | read-write | current | f2000EAS Series card MSTI Port Configuration: MSTI2 Aggregated Ports Configuration - Path Cost Valid values are in the range 0 to 200000000. Setting 0 means Au… |
| 1.3.6.1.4.1.4756.20.732.20.1.627 | Columnf2000EASMSTI2AggregatedPriorityRemoteB | read-write | current | f2000EAS Series card MSTI Port Configuration: MSTI2 Aggregated Ports Configuration - Priority |
| 1.3.6.1.4.1.4756.20.732.20.1.628 | Columnf2000EASMSTI2Port1PathCostRemoteB | read-write | current | f2000EAS Series card MSTI Port Configuration: MSTI2 Normal Port1 Configuration - Path Cost Valid values are in the range 0 to 200000000. Setting 0 means Auto p… |
| 1.3.6.1.4.1.4756.20.732.20.1.629 | Columnf2000EASMSTI2Port1PriorityRemoteB | read-write | current | f2000EAS Series card MSTI Port Configuration: MSTI2 Normal Port1 Configuration - Priority |
| 1.3.6.1.4.1.4756.20.732.20.1.630 | Columnf2000EASMSTI2Port2PathCostRemoteB | read-write | current | f2000EAS Series card MSTI Port Configuration: MSTI2 Normal Port2 Configuration - Path Cost Valid values are in the range 0 to 200000000. Setting 0 means Auto p… |
| 1.3.6.1.4.1.4756.20.732.20.1.631 | Columnf2000EASMSTI2Port2PriorityRemoteB | read-write | current | f2000EAS Series card MSTI Port Configuration: MSTI2 Normal Port2 Configuration - Priority |
| 1.3.6.1.4.1.4756.20.732.20.1.632 | Columnf2000EASMSTI2Port3PathCostRemoteB | read-write | current | f2000EAS Series card MSTI Port Configuration: MSTI2 Normal Port3 Configuration - Path Cost Valid values are in the range 0 to 200000000. Setting 0 means Auto p… |
| 1.3.6.1.4.1.4756.20.732.20.1.633 | Columnf2000EASMSTI2Port3PriorityRemoteB | read-write | current | f2000EAS Series card MSTI Port Configuration: MSTI2 Normal Port3 Configuration - Priority |
| 1.3.6.1.4.1.4756.20.732.20.1.634 | Columnf2000EASMSTI2Port4PathCostRemoteB | read-write | current | f2000EAS Series card MSTI Port Configuration: MSTI2 Normal Port4 Configuration - Path Cost Valid values are in the range 0 to 200000000. Setting 0 means Auto p… |
| 1.3.6.1.4.1.4756.20.732.20.1.635 | Columnf2000EASMSTI2Port4PriorityRemoteB | read-write | current | f2000EAS Series card MSTI Port Configuration: MSTI2 Normal Port4 Configuration - Priority |
| 1.3.6.1.4.1.4756.20.732.20.1.636 | Columnf2000EASMSTI3AggregatedPathCostRemoteB | read-write | current | f2000EAS Series card MSTI Port Configuration: MSTI3 Aggregated Ports Configuration - Path Cost Valid values are in the range 0 to 200000000. Setting 0 means Au… |
| 1.3.6.1.4.1.4756.20.732.20.1.637 | Columnf2000EASMSTI3AggregatedPriorityRemoteB | read-write | current | f2000EAS Series card MSTI Port Configuration: MSTI3 Aggregated Ports Configuration - Priority |
| 1.3.6.1.4.1.4756.20.732.20.1.638 | Columnf2000EASMSTI3Port1PathCostRemoteB | read-write | current | f2000EAS Series card MSTI Port Configuration: MSTI3 Normal Port1 Configuration - Path Cost Valid values are in the range 0 to 200000000. Setting 0 means Auto p… |
| 1.3.6.1.4.1.4756.20.732.20.1.639 | Columnf2000EASMSTI3Port1PriorityRemoteB | read-write | current | f2000EAS Series card MSTI Port Configuration: MSTI3 Normal Port1 Configuration - Priority |
| 1.3.6.1.4.1.4756.20.732.20.1.640 | Columnf2000EASMSTI3Port2PathCostRemoteB | read-write | current | f2000EAS Series card MSTI Port Configuration: MSTI3 Normal Port2 Configuration - Path Cost Valid values are in the range 0 to 200000000. Setting 0 means Auto p… |
| 1.3.6.1.4.1.4756.20.732.20.1.641 | Columnf2000EASMSTI3Port2PriorityRemoteB | read-write | current | f2000EAS Series card MSTI Port Configuration: MSTI3 Normal Port2 Configuration - Priority |
| 1.3.6.1.4.1.4756.20.732.20.1.642 | Columnf2000EASMSTI3Port3PathCostRemoteB | read-write | current | f2000EAS Series card MSTI Port Configuration: MSTI1 Normal Port3 Configuration - Path Cost Valid values are in the range 0 to 200000000. Setting 0 means Auto p… |
| 1.3.6.1.4.1.4756.20.732.20.1.643 | Columnf2000EASMSTI3Port3PriorityRemoteB | read-write | current | f2000EAS Series card MSTI Port Configuration: MSTI3 Normal Port3 Configuration - Priority |
| 1.3.6.1.4.1.4756.20.732.20.1.644 | Columnf2000EASMSTI3Port4PathCostRemoteB | read-write | current | f2000EAS Series card MSTI Port Configuration: MSTI3 Normal Port4 Configuration - Path Cost Valid values are in the range 0 to 200000000. Setting 0 means Auto p… |
| 1.3.6.1.4.1.4756.20.732.20.1.645 | Columnf2000EASMSTI3Port4PriorityRemoteB | read-write | current | f2000EAS Series card MSTI Port Configuration: MSTI3 Normal Port4 Configuration - Priority |
| 1.3.6.1.4.1.4756.20.732.20.1.646 | Columnf2000EASMSTI4AggregatedPathCostRemoteB | read-write | current | f2000EAS Series card MSTI Port Configuration: MSTI4 Aggregated Ports Configuration - Path Cost Valid values are in the range 0 to 200000000. Setting 0 means Au… |
| 1.3.6.1.4.1.4756.20.732.20.1.647 | Columnf2000EASMSTI4AggregatedPriorityRemoteB | read-write | current | f2000EAS Series card MSTI Port Configuration: MSTI4 Aggregated Ports Configuration - Priority |
| 1.3.6.1.4.1.4756.20.732.20.1.648 | Columnf2000EASMSTI4Port1PathCostRemoteB | read-write | current | f2000EAS Series card MSTI Port Configuration: MSTI4 Normal Port1 Configuration - Path Cost Valid values are in the range 0 to 200000000. Setting 0 means Auto p… |
| 1.3.6.1.4.1.4756.20.732.20.1.649 | Columnf2000EASMSTI4Port1PriorityRemoteB | read-write | current | f2000EAS Series card MSTI Port Configuration: MSTI4 Normal Port1 Configuration - Priority |
| 1.3.6.1.4.1.4756.20.732.20.1.650 | Columnf2000EASMSTI4Port2PathCostRemoteB | read-write | current | f2000EAS Series card MSTI Port Configuration: MSTI4 Normal Port2 Configuration - Path Cost Valid values are in the range 0 to 200000000. Setting 0 means Auto p… |
| 1.3.6.1.4.1.4756.20.732.20.1.651 | Columnf2000EASMSTI4Port2PriorityRemoteB | read-write | current | f2000EAS Series card MSTI Port Configuration: MSTI4 Normal Port2 Configuration - Priority |
| 1.3.6.1.4.1.4756.20.732.20.1.652 | Columnf2000EASMSTI4Port3PathCostRemoteB | read-write | current | f2000EAS Series card MSTI Port Configuration: MSTI1 Normal Port3 Configuration - Path Cost Valid values are in the range 0 to 200000000. Setting 0 means Auto p… |
| 1.3.6.1.4.1.4756.20.732.20.1.653 | Columnf2000EASMSTI4Port3PriorityRemoteB | read-write | current | f2000EAS Series card MSTI Port Configuration: MSTI4 Normal Port3 Configuration - Priority |
| 1.3.6.1.4.1.4756.20.732.20.1.654 | Columnf2000EASMSTI4Port4PathCostRemoteB | read-write | current | f2000EAS Series card MSTI Port Configuration: MSTI4 Normal Port4 Configuration - Path Cost Valid values are in the range 0 to 200000000. Setting 0 means Auto p… |
| 1.3.6.1.4.1.4756.20.732.20.1.655 | Columnf2000EASMSTI4Port4PriorityRemoteB | read-write | current | f2000EAS Series card MSTI Port Configuration: MSTI4 Normal Port4 Configuration - Priority |
| 1.3.6.1.4.1.4756.20.732.20.1.656 | Columnf2000EASMSTI5AggregatedPathCostRemoteB | read-write | current | f2000EAS Series card MSTI Port Configuration: MSTI5 Aggregated Ports Configuration - Path Cost Valid values are in the range 0 to 200000000. Setting 0 means Au… |
| 1.3.6.1.4.1.4756.20.732.20.1.657 | Columnf2000EASMSTI5AggregatedPriorityRemoteB | read-write | current | f2000EAS Series card MSTI Port Configuration: MSTI5 Aggregated Ports Configuration - Priority |
| 1.3.6.1.4.1.4756.20.732.20.1.658 | Columnf2000EASMSTI5Port1PathCostRemoteB | read-write | current | f2000EAS Series card MSTI Port Configuration: MSTI5 Normal Port1 Configuration - Path Cost Valid values are in the range 0 to 200000000. Setting 0 means Auto p… |
| 1.3.6.1.4.1.4756.20.732.20.1.659 | Columnf2000EASMSTI5Port1PriorityRemoteB | read-write | current | f2000EAS Series card MSTI Port Configuration: MSTI5 Normal Port1 Configuration - Priority |
| 1.3.6.1.4.1.4756.20.732.20.1.660 | Columnf2000EASMSTI5Port2PathCostRemoteB | read-write | current | f2000EAS Series card MSTI Port Configuration: MSTI5 Normal Port2 Configuration - Path Cost Valid values are in the range 0 to 200000000. Setting 0 means Auto p… |
| 1.3.6.1.4.1.4756.20.732.20.1.661 | Columnf2000EASMSTI5Port2PriorityRemoteB | read-write | current | f2000EAS Series card MSTI Port Configuration: MSTI5 Normal Port2 Configuration - Priority |
| 1.3.6.1.4.1.4756.20.732.20.1.662 | Columnf2000EASMSTI5Port3PathCostRemoteB | read-write | current | f2000EAS Series card MSTI Port Configuration: MSTI5 Normal Port3 Configuration - Path Cost Valid values are in the range 0 to 200000000. Setting 0 means Auto p… |
| 1.3.6.1.4.1.4756.20.732.20.1.663 | Columnf2000EASMSTI5Port3PriorityRemoteB | read-write | current | f2000EAS Series card MSTI Port Configuration: MSTI5 Normal Port3 Configuration - Priority |
| 1.3.6.1.4.1.4756.20.732.20.1.664 | Columnf2000EASMSTI5Port4PathCostRemoteB | read-write | current | f2000EAS Series card MSTI Port Configuration: MSTI5 Normal Port4 Configuration - Path Cost Valid values are in the range 0 to 200000000. Setting 0 means Auto p… |
| 1.3.6.1.4.1.4756.20.732.20.1.665 | Columnf2000EASMSTI5Port4PriorityRemoteB | read-write | current | f2000EAS Series card MSTI Port Configuration: MSTI5 Normal Port4 Configuration - Priority |
| 1.3.6.1.4.1.4756.20.732.20.1.666 | Columnf2000EASMSTI6AggregatedPathCostRemoteB | read-write | current | f2000EAS Series card MSTI Port Configuration: MSTI6 Aggregated Ports Configuration - Path Cost Valid values are in the range 0 to 200000000. Setting 0 means Au… |
| 1.3.6.1.4.1.4756.20.732.20.1.667 | Columnf2000EASMSTI6AggregatedPriorityRemoteB | read-write | current | f2000EAS Series card MSTI Port Configuration: MSTI6 Aggregated Ports Configuration - Priority |
| 1.3.6.1.4.1.4756.20.732.20.1.668 | Columnf2000EASMSTI6Port1PathCostRemoteB | read-write | current | f2000EAS Series card MSTI Port Configuration: MSTI6 Normal Port1 Configuration - Path Cost Valid values are in the range 0 to 200000000. Setting 0 means Auto p… |
| 1.3.6.1.4.1.4756.20.732.20.1.669 | Columnf2000EASMSTI6Port1PriorityRemoteB | read-write | current | f2000EAS Series card MSTI Port Configuration: MSTI6 Normal Port1 Configuration - Priority |
| 1.3.6.1.4.1.4756.20.732.20.1.670 | Columnf2000EASMSTI6Port2PathCostRemoteB | read-write | current | f2000EAS Series card MSTI Port Configuration: MSTI6 Normal Port2 Configuration - Path Cost Valid values are in the range 0 to 200000000. Setting 0 means Auto p… |
| 1.3.6.1.4.1.4756.20.732.20.1.671 | Columnf2000EASMSTI6Port2PriorityRemoteB | read-write | current | f2000EAS Series card MSTI Port Configuration: MSTI6 Normal Port2 Configuration - Priority |
| 1.3.6.1.4.1.4756.20.732.20.1.672 | Columnf2000EASMSTI6Port3PathCostRemoteB | read-write | current | f2000EAS Series card MSTI Port Configuration: MSTI6 Normal Port3 Configuration - Path Cost Valid values are in the range 0 to 200000000. Setting 0 means Auto p… |
| 1.3.6.1.4.1.4756.20.732.20.1.673 | Columnf2000EASMSTI6Port3PriorityRemoteB | read-write | current | f2000EAS Series card MSTI Port Configuration: MSTI6 Normal Port3 Configuration - Priority |
| 1.3.6.1.4.1.4756.20.732.20.1.674 | Columnf2000EASMSTI6Port4PathCostRemoteB | read-write | current | f2000EAS Series card MSTI Port Configuration: MSTI6 Normal Port4 Configuration - Path Cost Valid values are in the range 0 to 200000000. Setting 0 means Auto p… |
| 1.3.6.1.4.1.4756.20.732.20.1.675 | Columnf2000EASMSTI6Port4PriorityRemoteB | read-write | current | f2000EAS Series card MSTI Port Configuration: MSTI6 Normal Port4 Configuration - Priority |
| 1.3.6.1.4.1.4756.20.732.20.1.676 | Columnf2000EASMSTI7AggregatedPathCostRemoteB | read-write | current | f2000EAS Series card MSTI Port Configuration: MSTI7 Aggregated Ports Configuration - Path Cost Valid values are in the range 0 to 200000000. Setting 0 means Au… |
| 1.3.6.1.4.1.4756.20.732.20.1.677 | Columnf2000EASMSTI7AggregatedPriorityRemoteB | read-write | current | f2000EAS Series card MSTI Port Configuration: MSTI7 Aggregated Ports Configuration - Priority |
| 1.3.6.1.4.1.4756.20.732.20.1.678 | Columnf2000EASMSTI7Port1PathCostRemoteB | read-write | current | f2000EAS Series card MSTI Port Configuration: MSTI1 Normal Port1 Configuration - Path Cost Valid values are in the range 0 to 200000000. Setting 0 means Auto p… |
| 1.3.6.1.4.1.4756.20.732.20.1.679 | Columnf2000EASMSTI7Port1PriorityRemoteB | read-write | current | f2000EAS Series card MSTI Port Configuration: MSTI1 Normal Port7 Configuration - Priority |
| 1.3.6.1.4.1.4756.20.732.20.1.680 | Columnf2000EASMSTI7Port2PathCostRemoteB | read-write | current | f2000EAS Series card MSTI Port Configuration: MSTI7 Normal Port2 Configuration - Path Cost Valid values are in the range 0 to 200000000. Setting 0 means Auto p… |
| 1.3.6.1.4.1.4756.20.732.20.1.681 | Columnf2000EASMSTI7Port2PriorityRemoteB | read-write | current | f2000EAS Series card MSTI Port Configuration: MSTI7 Normal Port2 Configuration - Priority |
| 1.3.6.1.4.1.4756.20.732.20.1.682 | Columnf2000EASMSTI7Port3PathCostRemoteB | read-write | current | f2000EAS Series card MSTI Port Configuration: MSTI7 Normal Port3 Configuration - Path Cost Valid values are in the range 0 to 200000000. Setting 0 means Auto p… |
| 1.3.6.1.4.1.4756.20.732.20.1.683 | Columnf2000EASMSTI7Port3PriorityRemoteB | read-write | current | f2000EAS Series card MSTI Port Configuration: MSTI7 Normal Port3 Configuration - Priority |
| 1.3.6.1.4.1.4756.20.732.20.1.684 | Columnf2000EASMSTI7Port4PathCostRemoteB | read-write | current | f2000EAS Series card MSTI Port Configuration: MSTI7 Normal Port4 Configuration - Path Cost Valid values are in the range 0 to 200000000. Setting 0 means Auto p… |
| 1.3.6.1.4.1.4756.20.732.20.1.685 | Columnf2000EASMSTI7Port4PriorityRemoteB | read-write | current | f2000EAS Series card MSTI Port Configuration: MSTI7 Normal Port4 Configuration - Priority |
| 1.3.6.1.4.1.4756.20.732.20.1.686 | Columnf2000EASCISTBridgeIDRemoteB | read-only | current | f2000EAS Series card STP Bridges status: CIST - Bridge ID |
| 1.3.6.1.4.1.4756.20.732.20.1.687 | Columnf2000EASCISTRootIDRemoteB | read-only | current | f2000EAS Series card STP Bridges status: CIST - Root ID |
| 1.3.6.1.4.1.4756.20.732.20.1.688 | Columnf2000EASCISTRootPortRemoteB | read-only | current | f2000EAS Series card STP Bridges status: CIST - Root Port |
| 1.3.6.1.4.1.4756.20.732.20.1.689 | Columnf2000EASCISTRootCostRemoteB | read-only | current | f2000EAS Series card STP Bridges status: CIST - Root Cost |
| 1.3.6.1.4.1.4756.20.732.20.1.690 | Columnf2000EASCISTTopologyFlagRemoteB | read-only | current | f2000EAS Series card STP Bridges status: CIST - Topology Flag |
| 1.3.6.1.4.1.4756.20.732.20.1.691 | Columnf2000EASCISTTopologyChangeLastRemoteB | read-only | current | f2000EAS Series card STP Bridges status: CIST - Topology Change Last |
| 1.3.6.1.4.1.4756.20.732.20.1.692 | Columnf2000EASMSTI1BridgeIDRemoteB | read-only | current | f2000EAS Series card STP Bridges status: MSTI1 - Bridge ID |
| 1.3.6.1.4.1.4756.20.732.20.1.693 | Columnf2000EASMSTI1RootIDRemoteB | read-only | current | f2000EAS Series card STP Bridges status: MSTI1 - Root ID |
| 1.3.6.1.4.1.4756.20.732.20.1.694 | Columnf2000EASMSTI1RootPortRemoteB | read-only | current | f2000EAS Series card STP Bridges status: MSTI1 - Root ID |
| 1.3.6.1.4.1.4756.20.732.20.1.695 | Columnf2000EASMSTI1RootCostRemoteB | read-only | current | f2000EAS Series card STP Bridges status: MSTI1 - Root Cost |
| 1.3.6.1.4.1.4756.20.732.20.1.696 | Columnf2000EASMSTI1TopologyFlagRemoteB | read-only | current | f2000EAS Series card STP Bridges status: MSTI1 - Topology Flag |
| 1.3.6.1.4.1.4756.20.732.20.1.697 | Columnf2000EASMSTI1TopologyChangeLastRemoteB | read-only | current | f2000EAS Series card STP Bridges status: MSTI1 - Topology Change Last |
| 1.3.6.1.4.1.4756.20.732.20.1.698 | Columnf2000EASMSTI2BridgeIDRemoteB | read-only | current | f2000EAS Series card STP Bridges status: MSTI2 - Bridge ID |
| 1.3.6.1.4.1.4756.20.732.20.1.699 | Columnf2000EASMSTI2RootIDRemoteB | read-only | current | f2000EAS Series card STP Bridges status: MSTI2 - Root ID |
| 1.3.6.1.4.1.4756.20.732.20.1.700 | Columnf2000EASMSTI2RootPortRemoteB | read-only | current | f2000EAS Series card STP Bridges status: MSTI2 - Root ID |
| 1.3.6.1.4.1.4756.20.732.20.1.701 | Columnf2000EASMSTI2RootCostRemoteB | read-only | current | f2000EAS Series card STP Bridges status: MSTI2 - Root Cost |
| 1.3.6.1.4.1.4756.20.732.20.1.702 | Columnf2000EASMSTI2TopologyFlagRemoteB | read-only | current | f2000EAS Series card STP Bridges status: MSTI2 - Topology Flag |
| 1.3.6.1.4.1.4756.20.732.20.1.703 | Columnf2000EASMSTI2TopologyChangeLastRemoteB | read-only | current | f2000EAS Series card STP Bridges status: MSTI2 - Topology Change Last |
| 1.3.6.1.4.1.4756.20.732.20.1.704 | Columnf2000EASMSTI3BridgeIDRemoteB | read-only | current | f2000EAS Series card STP Bridges status: MSTI3 - Bridge ID |
| 1.3.6.1.4.1.4756.20.732.20.1.705 | Columnf2000EASMSTI3RootIDRemoteB | read-only | current | f2000EAS Series card STP Bridges status: MSTI3 - Root ID |
| 1.3.6.1.4.1.4756.20.732.20.1.706 | Columnf2000EASMSTI3RootPortRemoteB | read-only | current | f2000EAS Series card STP Bridges status: MSTI3 - Root ID |
| 1.3.6.1.4.1.4756.20.732.20.1.707 | Columnf2000EASMSTI3RootCostRemoteB | read-only | current | f2000EAS Series card STP Bridges status: MSTI3 - Root Cost |
| 1.3.6.1.4.1.4756.20.732.20.1.708 | Columnf2000EASMSTI3TopologyFlagRemoteB | read-only | current | f2000EAS Series card STP Bridges status: MSTI3 - Topology Flag |
| 1.3.6.1.4.1.4756.20.732.20.1.709 | Columnf2000EASMSTI3TopologyChangeLastRemoteB | read-only | current | f2000EAS Series card STP Bridges status: MSTI3 - Topology Change Last |
| 1.3.6.1.4.1.4756.20.732.20.1.710 | Columnf2000EASMSTI4BridgeIDRemoteB | read-only | current | f2000EAS Series card STP Bridges status: MSTI4 - Bridge ID |
| 1.3.6.1.4.1.4756.20.732.20.1.711 | Columnf2000EASMSTI4RootIDRemoteB | read-only | current | f2000EAS Series card STP Bridges status: MSTI4 - Root ID |
| 1.3.6.1.4.1.4756.20.732.20.1.712 | Columnf2000EASMSTI4RootPortRemoteB | read-only | current | f2000EAS Series card STP Bridges status: MSTI4 - Root ID |
| 1.3.6.1.4.1.4756.20.732.20.1.713 | Columnf2000EASMSTI4RootCostRemoteB | read-only | current | f2000EAS Series card STP Bridges status: MSTI4 - Root Cost |
| 1.3.6.1.4.1.4756.20.732.20.1.714 | Columnf2000EASMSTI4TopologyFlagRemoteB | read-only | current | f2000EAS Series card STP Bridges status: MSTI4 - Topology Flag |
| 1.3.6.1.4.1.4756.20.732.20.1.715 | Columnf2000EASMSTI4TopologyChangeLastRemoteB | read-only | current | f2000EAS Series card STP Bridges status: MSTI4 - Topology Change Last |
| 1.3.6.1.4.1.4756.20.732.20.1.716 | Columnf2000EASMSTI5BridgeIDRemoteB | read-only | current | f2000EAS Series card STP Bridges status: MSTI5 - Bridge ID |
| 1.3.6.1.4.1.4756.20.732.20.1.717 | Columnf2000EASMSTI5RootIDRemoteB | read-only | current | f2000EAS Series card STP Bridges status: MSTI5 - Root ID |
| 1.3.6.1.4.1.4756.20.732.20.1.718 | Columnf2000EASMSTI5RootPortRemoteB | read-only | current | f2000EAS Series card STP Bridges status: MSTI5 - Root ID |
| 1.3.6.1.4.1.4756.20.732.20.1.719 | Columnf2000EASMSTI5RootCostRemoteB | read-only | current | f2000EAS Series card STP Bridges status: MSTI5 - Root Cost |
| 1.3.6.1.4.1.4756.20.732.20.1.720 | Columnf2000EASMSTI5TopologyFlagRemoteB | read-only | current | f2000EAS Series card STP Bridges status: MSTI5 - Topology Flag |
| 1.3.6.1.4.1.4756.20.732.20.1.721 | Columnf2000EASMSTI5TopologyChangeLastRemoteB | read-only | current | f2000EAS Series card STP Bridges status: MSTI5 - Topology Change Last |
| 1.3.6.1.4.1.4756.20.732.20.1.722 | Columnf2000EASMSTI6BridgeIDRemoteB | read-only | current | f2000EAS Series card STP Bridges status: MSTI6 - Bridge ID |
| 1.3.6.1.4.1.4756.20.732.20.1.723 | Columnf2000EASMSTI6RootIDRemoteB | read-only | current | f2000EAS Series card STP Bridges status: MSTI6 - Root ID |
| 1.3.6.1.4.1.4756.20.732.20.1.724 | Columnf2000EASMSTI6RootPortRemoteB | read-only | current | f2000EAS Series card STP Bridges status: MSTI6 - Root ID |
| 1.3.6.1.4.1.4756.20.732.20.1.725 | Columnf2000EASMSTI6RootCostRemoteB | read-only | current | f2000EAS Series card STP Bridges status: MSTI6 - Root Cost |
| 1.3.6.1.4.1.4756.20.732.20.1.726 | Columnf2000EASMSTI6TopologyFlagRemoteB | read-only | current | f2000EAS Series card STP Bridges status: MSTI6 - Topology Flag |
| 1.3.6.1.4.1.4756.20.732.20.1.727 | Columnf2000EASMSTI6TopologyChangeLastRemoteB | read-only | current | f2000EAS Series card STP Bridges status: MSTI6 - Topology Change Last |
| 1.3.6.1.4.1.4756.20.732.20.1.728 | Columnf2000EASMSTI7BridgeIDRemoteB | read-only | current | f2000EAS Series card STP Bridges status: MSTI7 - Bridge ID |
| 1.3.6.1.4.1.4756.20.732.20.1.729 | Columnf2000EASMSTI7RootIDRemoteB | read-only | current | f2000EAS Series card STP Bridges status: MSTI7 - Root ID |
| 1.3.6.1.4.1.4756.20.732.20.1.730 | Columnf2000EASMSTI7RootPortRemoteB | read-only | current | f2000EAS Series card STP Bridges status: MSTI7 - Root ID |
| 1.3.6.1.4.1.4756.20.732.20.1.731 | Columnf2000EASMSTI7RootCostRemoteB | read-only | current | f2000EAS Series card STP Bridges status: MSTI7 - Root Cost |
| 1.3.6.1.4.1.4756.20.732.20.1.732 | Columnf2000EASMSTI7TopologyFlagRemoteB | read-only | current | f2000EAS Series card STP Bridges status: MSTI7 - Topology Flag |
| 1.3.6.1.4.1.4756.20.732.20.1.733 | Columnf2000EASMSTI7TopologyChangeLastRemoteB | read-only | current | f2000EAS Series card STP Bridges status: MSTI7 - Topology Change Last |
| 1.3.6.1.4.1.4756.20.732.20.1.734 | Columnf2000EASSTPPortStatusInst1PortRemoteB | read-only | current | f2000EAS Series card STP Port status: Instance1 - Port |
| 1.3.6.1.4.1.4756.20.732.20.1.735 | Columnf2000EASSTPPortStatusInst1CISTRoleRemoteB | read-only | current | f2000EAS Series card STP Port status: Instance1 - CIST Role |
| 1.3.6.1.4.1.4756.20.732.20.1.736 | Columnf2000EASSTPPortStatusInst1CISTStateRemoteB | read-only | current | f2000EAS Series card STP Port status: Instance1 - CIST State |
| 1.3.6.1.4.1.4756.20.732.20.1.737 | Columnf2000EASSTPPortStatusInst1UptimeRemoteB | read-only | current | f2000EAS Series card STP Port status: Instance1 -Uptime |
| 1.3.6.1.4.1.4756.20.732.20.1.738 | Columnf2000EASSTPPortStatusInst2PortRemoteB | read-only | current | f2000EAS Series card STP Port status: Instance2 - Port |
| 1.3.6.1.4.1.4756.20.732.20.1.739 | Columnf2000EASSTPPortStatusInst2CISTRoleRemoteB | read-only | current | f2000EAS Series card STP Port status: Instance2 - CIST Role |
| 1.3.6.1.4.1.4756.20.732.20.1.740 | Columnf2000EASSTPPortStatusInst2CISTStateRemoteB | read-only | current | f2000EAS Series card STP Port status: Instance2 - CIST State |
| 1.3.6.1.4.1.4756.20.732.20.1.741 | Columnf2000EASSTPPortStatusInst2UptimeRemoteB | read-only | current | f2000EAS Series card STP Port status: Instance2 -Uptime |
| 1.3.6.1.4.1.4756.20.732.20.1.742 | Columnf2000EASSTPPortStatusInst3PortRemoteB | read-only | current | f2000EAS Series card STP Port status: Instance3 - Port |
| 1.3.6.1.4.1.4756.20.732.20.1.743 | Columnf2000EASSTPPortStatusInst3CISTRoleRemoteB | read-only | current | f2000EAS Series card STP Port status: Instance3 - CIST Role |
| 1.3.6.1.4.1.4756.20.732.20.1.744 | Columnf2000EASSTPPortStatusInst3CISTStateRemoteB | read-only | current | f2000EAS Series card STP Port status: Instance3 - CIST State |
| 1.3.6.1.4.1.4756.20.732.20.1.745 | Columnf2000EASSTPPortStatusInst3UptimeRemoteB | read-only | current | f2000EAS Series card STP Port status: Instance3 -Uptime |
| 1.3.6.1.4.1.4756.20.732.20.1.746 | Columnf2000EASSTPPortStatusInst4PortRemoteB | read-only | current | f2000EAS Series card STP Port status: Instance4 - Port |
| 1.3.6.1.4.1.4756.20.732.20.1.747 | Columnf2000EASSTPPortStatusInst4CISTRoleRemoteB | read-only | current | f2000EAS Series card STP Port status: Instance4 - CIST Role |
| 1.3.6.1.4.1.4756.20.732.20.1.748 | Columnf2000EASSTPPortStatusInst4CISTStateRemoteB | read-only | current | f2000EAS Series card STP Port status: Instance4 - CIST State |
| 1.3.6.1.4.1.4756.20.732.20.1.749 | Columnf2000EASSTPPortStatusInst4UptimeRemoteB | read-only | current | f2000EAS Series card STP Port status: Instance4 -Uptime |
| 1.3.6.1.4.1.4756.20.732.20.1.750 | Columnf2000EASSTPStatisticsPort1TxMSTPRemoteB | read-only | current | f2000EAS Series card STP Port Statistics: Port1 -Transmitted MSTP |
| 1.3.6.1.4.1.4756.20.732.20.1.751 | Columnf2000EASSTPStatisticsPort1TxRSTPRemoteB | read-only | current | f2000EAS Series card STP Port Statistics: Port1 -Transmitted RSTP |
| 1.3.6.1.4.1.4756.20.732.20.1.752 | Columnf2000EASSTPStatisticsPort1TxSTPRemoteB | read-only | current | f2000EAS Series card STP Port Statistics: Port1 -Transmitted RSTP |
| 1.3.6.1.4.1.4756.20.732.20.1.753 | Columnf2000EASSTPStatisticsPort1TxTCNRemoteB | read-only | current | f2000EAS Series card STP Port Statistics: Port1 -Transmitted RSTP |
| 1.3.6.1.4.1.4756.20.732.20.1.754 | Columnf2000EASSTPStatisticsPort1RxMSTPRemoteB | read-only | current | f2000EAS Series card STP Port Statistics: Port1 -Received MSTP |
| 1.3.6.1.4.1.4756.20.732.20.1.755 | Columnf2000EASSTPStatisticsPort1RxRSTPRemoteB | read-only | current | f2000EAS Series card STP Port Statistics: Port1 -Received RSTP |
| 1.3.6.1.4.1.4756.20.732.20.1.756 | Columnf2000EASSTPStatisticsPort1RxSTPRemoteB | read-only | current | f2000EAS Series card STP Port Statistics: Port1 -Received RSTP |
| 1.3.6.1.4.1.4756.20.732.20.1.757 | Columnf2000EASSTPStatisticsPort1RxTCNRemoteB | read-only | current | f2000EAS Series card STP Port Statistics: Port1 -Received RSTP |
| 1.3.6.1.4.1.4756.20.732.20.1.758 | Columnf2000EASSTPStatisticsPort1DiscardUnknowRemoteB | read-only | current | f2000EAS Series card STP Port Statistics: Port1 -Discarded Unknown |
| 1.3.6.1.4.1.4756.20.732.20.1.759 | Columnf2000EASSTPStatisticsPort1DiscardIllegalRemoteB | read-only | current | f2000EAS Series card STP Port Statistics: Port1 -Discarded Illegal |
| 1.3.6.1.4.1.4756.20.732.20.1.760 | Columnf2000EASSTPStatisticsPort2TxMSTPRemoteB | read-only | current | f2000EAS Series card STP Port Statistics: Port2 -Transmitted MSTP |
| 1.3.6.1.4.1.4756.20.732.20.1.761 | Columnf2000EASSTPStatisticsPort2TxRSTPRemoteB | read-only | current | f2000EAS Series card STP Port Statistics: Port2 -Transmitted RSTP |
| 1.3.6.1.4.1.4756.20.732.20.1.762 | Columnf2000EASSTPStatisticsPort2TxSTPRemoteB | read-only | current | f2000EAS Series card STP Port Statistics: Port2 -Transmitted RSTP |
| 1.3.6.1.4.1.4756.20.732.20.1.763 | Columnf2000EASSTPStatisticsPort2TxTCNRemoteB | read-only | current | f2000EAS Series card STP Port Statistics: Port2 -Transmitted RSTP |
| 1.3.6.1.4.1.4756.20.732.20.1.764 | Columnf2000EASSTPStatisticsPort2RxMSTPRemoteB | read-only | current | f2000EAS Series card STP Port Statistics: Port2 -Received MSTP |
| 1.3.6.1.4.1.4756.20.732.20.1.765 | Columnf2000EASSTPStatisticsPort2RxRSTPRemoteB | read-only | current | f2000EAS Series card STP Port Statistics: Port1 -Received RSTP |
| 1.3.6.1.4.1.4756.20.732.20.1.766 | Columnf2000EASSTPStatisticsPort2RxSTPRemoteB | read-only | current | f2000EAS Series card STP Port Statistics: Port2 -Received RSTP |
| 1.3.6.1.4.1.4756.20.732.20.1.767 | Columnf2000EASSTPStatisticsPort2RxTCNRemoteB | read-only | current | f2000EAS Series card STP Port Statistics: Port2 -Received RSTP |
| 1.3.6.1.4.1.4756.20.732.20.1.768 | Columnf2000EASSTPStatisticsPort2DiscardUnknowRemoteB | read-only | current | f2000EAS Series card STP Port Statistics: Port2 -Discarded Unknown |
| 1.3.6.1.4.1.4756.20.732.20.1.769 | Columnf2000EASSTPStatisticsPort2DiscardIllegalRemoteB | read-only | current | f2000EAS Series card STP Port Statistics: Port2 -Discarded Illegal |
| 1.3.6.1.4.1.4756.20.732.20.1.770 | Columnf2000EASSTPStatisticsPort3TxMSTPRemoteB | read-only | current | f2000EAS Series card STP Port Statistics: Port3 -Transmitted MSTP |
| 1.3.6.1.4.1.4756.20.732.20.1.771 | Columnf2000EASSTPStatisticsPort3TxRSTPRemoteB | read-only | current | f2000EAS Series card STP Port Statistics: Port3 -Transmitted RSTP |
| 1.3.6.1.4.1.4756.20.732.20.1.772 | Columnf2000EASSTPStatisticsPort3TxSTPRemoteB | read-only | current | f2000EAS Series card STP Port Statistics: Port3 -Transmitted RSTP |
| 1.3.6.1.4.1.4756.20.732.20.1.773 | Columnf2000EASSTPStatisticsPort3TxTCNRemoteB | read-only | current | f2000EAS Series card STP Port Statistics: Port3 -Transmitted RSTP |
| 1.3.6.1.4.1.4756.20.732.20.1.774 | Columnf2000EASSTPStatisticsPort3RxMSTPRemoteB | read-only | current | f2000EAS Series card STP Port Statistics: Port3 -Received MSTP |
| 1.3.6.1.4.1.4756.20.732.20.1.775 | Columnf2000EASSTPStatisticsPort3RxRSTPRemoteB | read-only | current | f2000EAS Series card STP Port Statistics: Port3 -Received RSTP |
| 1.3.6.1.4.1.4756.20.732.20.1.776 | Columnf2000EASSTPStatisticsPort3RxSTPRemoteB | read-only | current | f2000EAS Series card STP Port Statistics: Port3 -Received RSTP |
| 1.3.6.1.4.1.4756.20.732.20.1.777 | Columnf2000EASSTPStatisticsPort3RxTCNRemoteB | read-only | current | f2000EAS Series card STP Port Statistics: Port3 -Received RSTP |
| 1.3.6.1.4.1.4756.20.732.20.1.778 | Columnf2000EASSTPStatisticsPort3DiscardUnknowRemoteB | read-only | current | f2000EAS Series card STP Port Statistics: Port3 -Discarded Unknown |
| 1.3.6.1.4.1.4756.20.732.20.1.779 | Columnf2000EASSTPStatisticsPort3DiscardIllegalRemoteB | read-only | current | f2000EAS Series card STP Port Statistics: Port3 -Discarded Illegal |
| 1.3.6.1.4.1.4756.20.732.20.1.780 | Columnf2000EASSTPStatisticsPort4TxMSTPRemoteB | read-only | current | f2000EAS Series card STP Port Statistics: Port4 -Transmitted MSTP |
| 1.3.6.1.4.1.4756.20.732.20.1.781 | Columnf2000EASSTPStatisticsPort4TxRSTPRemoteB | read-only | current | f2000EAS Series card STP Port Statistics: Port4 -Transmitted RSTP |
| 1.3.6.1.4.1.4756.20.732.20.1.782 | Columnf2000EASSTPStatisticsPort4TxSTPRemoteB | read-only | current | f2000EAS Series card STP Port Statistics: Port4 -Transmitted RSTP |
| 1.3.6.1.4.1.4756.20.732.20.1.783 | Columnf2000EASSTPStatisticsPort4TxTCNRemoteB | read-only | current | f2000EAS Series card STP Port Statistics: Port4 -Transmitted RSTP |
| 1.3.6.1.4.1.4756.20.732.20.1.784 | Columnf2000EASSTPStatisticsPort4RxMSTPRemoteB | read-only | current | f2000EAS Series card STP Port Statistics: Port4 -Received MSTP |
| 1.3.6.1.4.1.4756.20.732.20.1.785 | Columnf2000EASSTPStatisticsPort4RxRSTPRemoteB | read-only | current | f2000EAS Series card STP Port Statistics: Port4 -Received RSTP |
| 1.3.6.1.4.1.4756.20.732.20.1.786 | Columnf2000EASSTPStatisticsPort4RxSTPRemoteB | read-only | current | f2000EAS Series card STP Port Statistics: Port4 -Received RSTP |
| 1.3.6.1.4.1.4756.20.732.20.1.787 | Columnf2000EASSTPStatisticsPort4RxTCNRemoteB | read-only | current | f2000EAS Series card STP Port Statistics: Port4 -Received RSTP |
| 1.3.6.1.4.1.4756.20.732.20.1.788 | Columnf2000EASSTPStatisticsPort4DiscardUnknowRemoteB | read-only | current | f2000EAS Series card STP Port Statistics: Port4 -Discarded Unknown |
| 1.3.6.1.4.1.4756.20.732.20.1.789 | Columnf2000EASSTPStatisticsPort4DiscardIllegalRemoteB | read-only | current | f2000EAS Series card STP Port Statistics: Port4 -Discarded Illegal |
| 1.3.6.1.4.1.4756.20.732.20.1.790 | Columnf2000EASSTPStatisticsPortClearCounterRemoteB | read-write | current | f2000EAS Series card STP Port Statistics: Clear Counters 0: OFff 1: Action |
| 1.3.6.1.4.1.4756.20.732.20.1.791 | Columnf2000EASAllowedAccessVLANsRemoteB | read-write | current | f2000EAS Series card Global VLAN Configuration: Allowed Access VLANs By default, only VLAN 1 is enabled. More VLANs may be created by using a list syntax where… |
| 1.3.6.1.4.1.4756.20.732.20.1.792 | Columnf2000EASVlanEthertypeRemoteB | read-write | current | f2000EAS Series card Global VLAN Configuration: Ethertype for Custom S-ports The format of 'Ethernet Type' is restricted to 0x600-0xFFFF |
| 1.3.6.1.4.1.4756.20.732.20.1.793 | Columnf2000EASPort1VlanModeRemoteB | read-write | current | f2000EAS Series card Port VLAN Configuration : Port1 - Mode 0: Access 1: Trunk 2: Hybrid |
| 1.3.6.1.4.1.4756.20.732.20.1.794 | Columnf2000EASPort1VlanIDRemoteB | read-write | current | f2000EAS Series card Port VLAN Configuration : Port1 - VLAN ID |
| 1.3.6.1.4.1.4756.20.732.20.1.795 | Columnf2000EASPort1VlanTypeRemoteB | read-write | current | f2000EAS Series card Port VLAN Configuration : Port1 - VLAN Type 0: Unaware 1: C-port 2: S-port 3: S-custom-port |
| 1.3.6.1.4.1.4756.20.732.20.1.796 | Columnf2000EASPort1VlanIngressFilteringRemoteB | read-write | current | f2000EAS Series card Port VLAN Configuration : Port1 - Ingress Filtering 0: Off 1: On |
| 1.3.6.1.4.1.4756.20.732.20.1.797 | Columnf2000EASPort1VlanIngressAcceptanceRemoteB | read-write | current | f2000EAS Series card Port VLAN Configuration : Port1 - Ingress Acceptance 0: Tagged and untagged 1: Tagged only 2: Untagged only |
| 1.3.6.1.4.1.4756.20.732.20.1.798 | Columnf2000EASPort1VlanEgressTaggingRemoteB | read-write | current | f2000EAS Series card Port VLAN Configuration : Port1 - Egress Tagging 0: Untag port vlan 1: Tag all 2: Untag all |
| 1.3.6.1.4.1.4756.20.732.20.1.799 | Columnf2000EASPort1VlanEgressTaggedSpecificallyUntagRemoteB | read-write | current | Ports in Hybrid mode may specify the tagging of frames with VID on egress, which overrules the Egress Tagging setting. Frames classified to these VLANs are tra… |
| 1.3.6.1.4.1.4756.20.732.20.1.800 | Columnf2000EASPort1VlanEgressTaggedSpecificallyCtagRemoteB | read-write | current | Ports in Hybrid mode may specify the tagging of frames with VID on egress, which overrules the Egress Tagging setting. Frames classified to these VLANs are tra… |
| 1.3.6.1.4.1.4756.20.732.20.1.801 | Columnf2000EASPort1VlanEgressTaggedSpecificallyStagRemoteB | read-write | current | Ports in Hybrid mode may specify the tagging of frames with VID on egress, which overrules the Egress Tagging setting. Frames classified to these VLANs are tra… |
| 1.3.6.1.4.1.4756.20.732.20.1.802 | Columnf2000EASPort1VlanEgressTaggedSpecificallySCtagRemoteB | read-write | current | Ports in Hybrid mode may specify the tagging of frames with VID on egress, which overrules the Egress Tagging setting. Frames classified to these VLANs are tra… |
| 1.3.6.1.4.1.4756.20.732.20.1.803 | Columnf2000EASPort1AllowedVLANSRemoteB | read-write | current | f2000EAS Series card Global VLAN Configuration: Port1 - Allowed VLANs By default, only VLAN 1 is enabled. More VLANs may be created by using a list syntax wher… |
| 1.3.6.1.4.1.4756.20.732.20.1.804 | Columnf2000EASPort2VlanModeRemoteB | read-write | current | f2000EAS Series card Port VLAN Configuration : Port2 - Mode 0: Access 1: Trunk 2: Hybrid |
| 1.3.6.1.4.1.4756.20.732.20.1.805 | Columnf2000EASPort2VlanIDRemoteB | read-write | current | f2000EAS Series card Port VLAN Configuration : Port2 - VLAN ID |
| 1.3.6.1.4.1.4756.20.732.20.1.806 | Columnf2000EASPort2VlanTypeRemoteB | read-write | current | f2000EAS Series card Port VLAN Configuration : Port2 - VLAN Type 0: Unaware 1: C-port 2: S-port 3: S-custom-port |
| 1.3.6.1.4.1.4756.20.732.20.1.807 | Columnf2000EASPort2VlanIngressFilteringRemoteB | read-write | current | f2000EAS Series card Port VLAN Configuration : Port2 - Ingress Filtering 0: Off 1: On |
| 1.3.6.1.4.1.4756.20.732.20.1.808 | Columnf2000EASPort2VlanIngressAcceptanceRemoteB | read-write | current | f2000EAS Series card Port VLAN Configuration : Por2 - Ingress Acceptance 0: Tagged and untagged 1: Tagged only 2: Untagged only |
| 1.3.6.1.4.1.4756.20.732.20.1.809 | Columnf2000EASPort2VlanEgressTaggingRemoteB | read-write | current | f2000EAS Series card Port VLAN Configuration : Port2 - Egress Tagging 0: Untag port vlan 1: Tag all 2: Untag all |
| 1.3.6.1.4.1.4756.20.732.20.1.810 | Columnf2000EASPort2VlanEgressTaggedSpecificallyUntagRemoteB | read-write | current | Ports in Hybrid mode may specify the tagging of frames with VID on egress, which overrules the Egress Tagging setting. Frames classified to these VLANs are tra… |
| 1.3.6.1.4.1.4756.20.732.20.1.811 | Columnf2000EASPort2VlanEgressTaggedSpecificallyCtagRemoteB | read-write | current | Ports in Hybrid mode may specify the tagging of frames with VID on egress, which overrules the Egress Tagging setting. Frames classified to these VLANs are tra… |
| 1.3.6.1.4.1.4756.20.732.20.1.812 | Columnf2000EASPort2VlanEgressTaggedSpecificallyStagRemoteB | read-write | current | Ports in Hybrid mode may specify the tagging of frames with VID on egress, which overrules the Egress Tagging setting. Frames classified to these VLANs are tra… |
| 1.3.6.1.4.1.4756.20.732.20.1.813 | Columnf2000EASPort2VlanEgressTaggedSpecificallySCtagRemoteB | read-write | current | Ports in Hybrid mode may specify the tagging of frames with VID on egress, which overrules the Egress Tagging setting. Frames classified to these VLANs are tra… |
| 1.3.6.1.4.1.4756.20.732.20.1.814 | Columnf2000EASPort2AllowedVLANSRemoteB | read-write | current | f2000EAS Series card Global VLAN Configuration: Port2 - Allowed VLANs By default, only VLAN 1 is enabled. More VLANs may be created by using a list syntax wher… |
| 1.3.6.1.4.1.4756.20.732.20.1.815 | Columnf2000EASPort3VlanModeRemoteB | read-write | current | f2000EAS Series card Port VLAN Configuration : Port3 - Mode 0: Access 1: Trunk 2: Hybrid |
| 1.3.6.1.4.1.4756.20.732.20.1.816 | Columnf2000EASPort3VlanIDRemoteB | read-write | current | f2000EAS Series card Port VLAN Configuration : Port3 - VLAN ID |
| 1.3.6.1.4.1.4756.20.732.20.1.817 | Columnf2000EASPort3VlanTypeRemoteB | read-write | current | f2000EAS Series card Port VLAN Configuration : Port3 - VLAN Type 0: Unaware 1: C-port 2: S-port 3: S-custom-port |
| 1.3.6.1.4.1.4756.20.732.20.1.818 | Columnf2000EASPort3VlanIngressFilteringRemoteB | read-write | current | f2000EAS Series card Port VLAN Configuration : Port3 - Ingress Filtering 0: Off 1: On |
| 1.3.6.1.4.1.4756.20.732.20.1.819 | Columnf2000EASPort3VlanIngressAcceptanceRemoteB | read-write | current | f2000EAS Series card Port VLAN Configuration : Port3 - Ingress Acceptance 0: Tagged and untagged 1: Tagged only 2: Untagged only |
| 1.3.6.1.4.1.4756.20.732.20.1.820 | Columnf2000EASPort3VlanEgressTaggingRemoteB | read-write | current | f2000EAS Series card Port VLAN Configuration : Port3 - Egress Tagging 0: Untag port vlan 1: Tag all 2: Untag all |
| 1.3.6.1.4.1.4756.20.732.20.1.821 | Columnf2000EASPort3VlanEgressTaggedSpecificallyUntagRemoteB | read-write | current | Ports in Hybrid mode may specify the tagging of frames with VID on egress, which overrules the Egress Tagging setting. Frames classified to these VLANs are tra… |
| 1.3.6.1.4.1.4756.20.732.20.1.822 | Columnf2000EASPort3VlanEgressTaggedSpecificallyCtagRemoteB | read-write | current | Ports in Hybrid mode may specify the tagging of frames with VID on egress, which overrules the Egress Tagging setting. Frames classified to these VLANs are tra… |
| 1.3.6.1.4.1.4756.20.732.20.1.823 | Columnf2000EASPort3VlanEgressTaggedSpecificallyStagRemoteB | read-write | current | Ports in Hybrid mode may specify the tagging of frames with VID on egress, which overrules the Egress Tagging setting. Frames classified to these VLANs are tra… |
| 1.3.6.1.4.1.4756.20.732.20.1.824 | Columnf2000EASPort3VlanEgressTaggedSpecificallySCtagRemoteB | read-write | current | Ports in Hybrid mode may specify the tagging of frames with VID on egress, which overrules the Egress Tagging setting. Frames classified to these VLANs are tra… |
| 1.3.6.1.4.1.4756.20.732.20.1.825 | Columnf2000EASPort3AllowedVLANSRemoteB | read-write | current | f2000EAS Series card Global VLAN Configuration: Port3 - Allowed VLANs By default, only VLAN 1 is enabled. More VLANs may be created by using a list syntax wher… |
| 1.3.6.1.4.1.4756.20.732.20.1.826 | Columnf2000EASPort4VlanModeRemoteB | read-write | current | f2000EAS Series card Port VLAN Configuration : Port4 - Mode 0: Access 1: Trunk 2: Hybrid |
| 1.3.6.1.4.1.4756.20.732.20.1.827 | Columnf2000EASPort4VlanIDRemoteB | read-write | current | f2000EAS Series card Port VLAN Configuration : Port4 - VLAN ID |
| 1.3.6.1.4.1.4756.20.732.20.1.828 | Columnf2000EASPort4VlanTypeRemoteB | read-write | current | f2000EAS Series card Port VLAN Configuration : Port4 - VLAN Type 0: Unaware 1: C-port 2: S-port 3: S-custom-port |
| 1.3.6.1.4.1.4756.20.732.20.1.829 | Columnf2000EASPort4VlanIngressFilteringRemoteB | read-write | current | f2000EAS Series card Port VLAN Configuration : Port4 - Ingress Filtering 0: Off 1: On |
| 1.3.6.1.4.1.4756.20.732.20.1.830 | Columnf2000EASPort4VlanIngressAcceptanceRemoteB | read-write | current | f2000EAS Series card Port VLAN Configuration : Port4 - Ingress Acceptance 0: Tagged and untagged 1: Tagged only 2: Untagged only |
| 1.3.6.1.4.1.4756.20.732.20.1.831 | Columnf2000EASPort4VlanEgressTaggingRemoteB | read-write | current | f2000EAS Series card Port VLAN Configuration : Port4 - Egress Tagging 0: Untag port vlan 1: Tag all 2: Untag all |
| 1.3.6.1.4.1.4756.20.732.20.1.832 | Columnf2000EASPort4VlanEgressTaggedSpecificallyUntagRemoteB | read-write | current | Ports in Hybrid mode may specify the tagging of frames with VID on egress, which overrules the Egress Tagging setting. Frames classified to these VLANs are tra… |
| 1.3.6.1.4.1.4756.20.732.20.1.833 | Columnf2000EASPort4VlanEgressTaggedSpecificallyCtagRemoteB | read-write | current | Ports in Hybrid mode may specify the tagging of frames with VID on egress, which overrules the Egress Tagging setting. Frames classified to these VLANs are tra… |
| 1.3.6.1.4.1.4756.20.732.20.1.834 | Columnf2000EASPort4VlanEgressTaggedSpecificallyStagRemoteB | read-write | current | Ports in Hybrid mode may specify the tagging of frames with VID on egress, which overrules the Egress Tagging setting. Frames classified to these VLANs are tra… |
| 1.3.6.1.4.1.4756.20.732.20.1.835 | Columnf2000EASPort4VlanEgressTaggedSpecificallySCtagRemoteB | read-write | current | Ports in Hybrid mode may specify the tagging of frames with VID on egress, which overrules the Egress Tagging setting. Frames classified to these VLANs are tra… |
| 1.3.6.1.4.1.4756.20.732.20.1.836 | Columnf2000EASPort4AllowedVLANSRemoteB | read-write | current | f2000EAS Series card Global VLAN Configuration: Port4 - Allowed VLANs By default, only VLAN 1 is enabled. More VLANs may be created by using a list syntax wher… |
| 1.3.6.1.4.1.4756.20.732.20.1.837 | Columnf2000EASQOSPort1IngressRemoteB | read-write | current | f2000EAS Series card QOS Port1 Ingress Enabled 0: NO 1: YES |
| 1.3.6.1.4.1.4756.20.732.20.1.838 | Columnf2000EASQOSPort1IngressRateRemoteB | read-write | current | f2000EAS Series card QOS Port1 Ingress Rate |
| 1.3.6.1.4.1.4756.20.732.20.1.839 | Columnf2000EASQOSPort1IngressRateUnitRemoteB | read-write | current | f2000EAS Series card QOS Port1 Ingress Rate Unit 0: Kbps 1: Mbps 2: fps 3: kfps |
| 1.3.6.1.4.1.4756.20.732.20.1.840 | Columnf2000EASQOSPort1IngressBurstSizeRemoteB | read-write | current | f2000EAS Series card QOS Port1 Ingress Burst Size |
| 1.3.6.1.4.1.4756.20.732.20.1.841 | Columnf2000EASQOSPort2IngressRemoteB | read-write | current | f2000EAS Series card QOS Port2 Ingress Enabled 0: NO 1: YES |
| 1.3.6.1.4.1.4756.20.732.20.1.842 | Columnf2000EASQOSPort2IngressRateRemoteB | read-write | current | f2000EAS Series card QOS Port2 Ingress Rate |
| 1.3.6.1.4.1.4756.20.732.20.1.843 | Columnf2000EASQOSPort2IngressRateUnitRemoteB | read-write | current | f2000EAS Series card QOS Port2 Ingress Rate Unit 0: Kbps 1: Mbps 2: fps 3: kfps |
| 1.3.6.1.4.1.4756.20.732.20.1.844 | Columnf2000EASQOSPort2IngressBurstSizeRemoteB | read-write | current | f2000EAS Series card QOS Port2 Ingress Burst Size |
| 1.3.6.1.4.1.4756.20.732.20.1.845 | Columnf2000EASQOSPort3IngressRemoteB | read-write | current | f2000EAS Series card QOS Port3 Ingress Enabled 0: NO 1: YES |
| 1.3.6.1.4.1.4756.20.732.20.1.846 | Columnf2000EASQOSPort3IngressRateRemoteB | read-write | current | f2000EAS Series card QOS Port3 Ingress Rate |
| 1.3.6.1.4.1.4756.20.732.20.1.847 | Columnf2000EASQOSPort3IngressRateUnitRemoteB | read-write | current | f2000EAS Series card QOS Port3 Ingress Rate Unit 0: Kbps 1: Mbps 2: fps 3: kfps |
| 1.3.6.1.4.1.4756.20.732.20.1.848 | Columnf2000EASQOSPort3IngressBurstSizeRemoteB | read-write | current | f2000EAS Series card QOS Port3 Ingress Burst Size |
| 1.3.6.1.4.1.4756.20.732.20.1.849 | Columnf2000EASQOSPort4IngressRemoteB | read-write | current | f2000EAS Series card QOS Port4 Ingress Enabled 0: NO 1: YES |
| 1.3.6.1.4.1.4756.20.732.20.1.850 | Columnf2000EASQOSPort4IngressRateRemoteB | read-write | current | f2000EAS Series card QOS Port4 Ingress Rate |
| 1.3.6.1.4.1.4756.20.732.20.1.851 | Columnf2000EASQOSPort4IngressRateUnitRemoteB | read-write | current | f2000EAS Series card QOS Port4 Ingress Rate Unit 0: Kbps 1: Mbps 2: fps 3: kfps |
| 1.3.6.1.4.1.4756.20.732.20.1.852 | Columnf2000EASQOSPort4IngressBurstSizeRemoteB | read-write | current | f2000EAS Series card QOS Port4 Ingress Burst Size |
| 1.3.6.1.4.1.4756.20.732.20.1.853 | Columnf2000EASQOSPort1EgressRemoteB | read-write | current | f2000EAS Series card QOS Port1 Egress Enabled 0: NO 1: YES |
| 1.3.6.1.4.1.4756.20.732.20.1.854 | Columnf2000EASQOSPort1EgressRateRemoteB | read-write | current | f2000EAS Series card QOS Port1 Egress Rate |
| 1.3.6.1.4.1.4756.20.732.20.1.855 | Columnf2000EASQOSPort1EgressRateUnitRemoteB | read-write | current | f2000EAS Series card QOS Port1 Egress Rate Unit 0: Kbps 1: Mbps |
| 1.3.6.1.4.1.4756.20.732.20.1.856 | Columnf2000EASQOSPort2EgressRemoteB | read-write | current | f2000EAS Series card QOS Port2 Egress Enabled 0: NO 1: YES |
| 1.3.6.1.4.1.4756.20.732.20.1.857 | Columnf2000EASQOSPort2EgressRateRemoteB | read-write | current | f2000EAS Series card QOS Port2 Egress Rate |
| 1.3.6.1.4.1.4756.20.732.20.1.858 | Columnf2000EASQOSPort2EgressRateUnitRemoteB | read-write | current | f2000EAS Series card QOS Port2 Egress Rate Unit 0: Kbps 1: Mbps |
| 1.3.6.1.4.1.4756.20.732.20.1.859 | Columnf2000EASQOSPort3EgressRemoteB | read-write | current | f2000EAS Series card QOS Port3 Egress Enabled 0: NO 1: YES |
| 1.3.6.1.4.1.4756.20.732.20.1.860 | Columnf2000EASQOSPort3EgressRateRemoteB | read-write | current | f2000EAS Series card QOS Port3 Egress Rate |
| 1.3.6.1.4.1.4756.20.732.20.1.861 | Columnf2000EASQOSPort3EgressRateUnitRemoteB | read-write | current | f2000EAS Series card QOS Port3 Egress Rate Unit 0: Kbps 1: Mbps |
| 1.3.6.1.4.1.4756.20.732.20.1.862 | Columnf2000EASQOSPort4EgressRemoteB | read-write | current | f2000EAS Series card QOS Port4 Egress Enabled 0: NO 1: YES |
| 1.3.6.1.4.1.4756.20.732.20.1.863 | Columnf2000EASQOSPort4EgressRateRemoteB | read-write | current | f2000EAS Series card QOS Port4 Egress Rate |
| 1.3.6.1.4.1.4756.20.732.20.1.864 | Columnf2000EASQOSPort4EgressRateUnitRemoteB | read-write | current | f2000EAS Series card QOS Port4 Egress Rate Unit 0: Kbps 1: Mbps |
| 1.3.6.1.4.1.4756.20.732.20.1.865 | Columnf2000EASQOSUnicastRemoteB | read-write | current | f2000EAS Series card QOS Storm Control Configuration- Unicast 0: NO 1: YES |
| 1.3.6.1.4.1.4756.20.732.20.1.866 | Columnf2000EASQOSUnicastRateRemoteB | read-write | current | f2000EAS Series card QOS Storm Control Configuration- Unicast Rate |
| 1.3.6.1.4.1.4756.20.732.20.1.867 | Columnf2000EASQOSUnicastRateUnitRemoteB | read-only | current | f2000EAS Series card QOS Unicast Rate Unit 2: Fps 3: Kfps |
| 1.3.6.1.4.1.4756.20.732.20.1.868 | Columnf2000EASQOSMulticastRemoteB | read-write | current | f2000EAS Series card QOS Storm Control Configuration- Multicast 0: NO 1: YES |
| 1.3.6.1.4.1.4756.20.732.20.1.869 | Columnf2000EASQOSMulticastRateRemoteB | read-write | current | f2000EAS Series card QOS Storm Control Configuration- Multicast Rate |
| 1.3.6.1.4.1.4756.20.732.20.1.870 | Columnf2000EASQOSMulticastRateUnitRemoteB | read-only | current | f2000EAS Series card QOS Multicast Rate Unit 2: Fps 3: Kfps |
| 1.3.6.1.4.1.4756.20.732.20.1.871 | Columnf2000EASQOSBroadcastRemoteB | read-write | current | f2000EAS Series card QOS Storm Control Configuration- Broadcast 0: NO 1: YES |
| 1.3.6.1.4.1.4756.20.732.20.1.872 | Columnf2000EASQOSBroadcastRateRemoteB | read-write | current | f2000EAS Series card QOS Storm Control Configuration- Broadcast Rate |
| 1.3.6.1.4.1.4756.20.732.20.1.873 | Columnf2000EASQOSBroadcastRateUnitRemoteB | read-only | current | f2000EAS Series card QOS Broadcast Rate Unit 2: Fps 3: Kfps |
| 1.3.6.1.4.1.4756.20.732.20.1.874 | Columnf2000EASPort1LLFLogicRemoteB | read-write | current | f2000EAS Series card Port1 link loss forwarding - Logic 0: AND 1: OR |
| 1.3.6.1.4.1.4756.20.732.20.1.875 | Columnf2000EASPort1LLFLogicPort2RemoteB | read-write | current | f2000EAS Series card Port1 link loss forwarding - Link/Rx Loss Port2 0: NO 1: YES |
| 1.3.6.1.4.1.4756.20.732.20.1.876 | Columnf2000EASPort1LLFLogicPort3RemoteB | read-write | current | f2000EAS Series card Port1 link loss forwarding - Link/Rx Loss Port3 0: NO 1: YES |
| 1.3.6.1.4.1.4756.20.732.20.1.877 | Columnf2000EASPort1LLFLogicPort4RemoteB | read-write | current | f2000EAS Series card Port1 link loss forwarding - Link/Rx Loss Port4 0: NO 1: YES |
| 1.3.6.1.4.1.4756.20.732.20.1.878 | Columnf2000EASPort2LLFLogicRemoteB | read-write | current | f2000EAS Series card Port2 link loss forwarding - Logic 0: AND 1: OR |
| 1.3.6.1.4.1.4756.20.732.20.1.879 | Columnf2000EASPort2LLFLogicPort1RemoteB | read-write | current | f2000EAS Series card Port2 link loss forwarding - Link/Rx Loss Port1 0: NO 1: YES |
| 1.3.6.1.4.1.4756.20.732.20.1.880 | Columnf2000EASPort2LLFLogicPort3RemoteB | read-write | current | f2000EAS Series card Port2 link loss forwarding - Link/Rx Loss Port3 0: NO 1: YES |
| 1.3.6.1.4.1.4756.20.732.20.1.881 | Columnf2000EASPort2LLFLogicPort4RemoteB | read-write | current | f2000EAS Series card Port2 link loss forwarding - Link/Rx Loss Port4 0: NO 1: YES |
| 1.3.6.1.4.1.4756.20.732.20.1.882 | Columnf2000EASPort3LLFLogicRemoteB | read-write | current | f2000EAS Series card Port3 link loss forwarding - Logic 0: AND 1: OR |
| 1.3.6.1.4.1.4756.20.732.20.1.883 | Columnf2000EASPort3LLFLogicPort1RemoteB | read-write | current | f2000EAS Series card Port3 link loss forwarding - Link/Rx Loss Port1 0: NO 1: YES |
| 1.3.6.1.4.1.4756.20.732.20.1.884 | Columnf2000EASPort3LLFLogicPort2RemoteB | read-write | current | f2000EAS Series card Port3 link loss forwarding - Link/Rx Loss Port2 0: NO 1: YES |
| 1.3.6.1.4.1.4756.20.732.20.1.885 | Columnf2000EASPort3LLFLogicPort4RemoteB | read-write | current | f2000EAS Series card Port3 link loss forwarding - Link/Rx Loss Port4 0: NO 1: YES |
| 1.3.6.1.4.1.4756.20.732.20.1.886 | Columnf2000EASPort4LLFLogicRemoteB | read-write | current | f2000EAS Series card Port4 link loss forwarding - Logic 0: AND 1: OR |
| 1.3.6.1.4.1.4756.20.732.20.1.887 | Columnf2000EASPort4LLFLogicPort1RemoteB | read-write | current | f2000EAS Series card Port4 link loss forwarding - Link/Rx Loss Port1 0: NO 1: YES |
| 1.3.6.1.4.1.4756.20.732.20.1.888 | Columnf2000EASPort4LLFLogicPort2RemoteB | read-write | current | f2000EAS Series card Port4 link loss forwarding - Link/Rx Loss Port2 0: NO 1: YES |
| 1.3.6.1.4.1.4756.20.732.20.1.889 | Columnf2000EASPort4LLFLogicPort3RemoteB | read-write | current | f2000EAS Series card Port4 link loss forwarding - Link/Rx Loss Port3 0: NO 1: YES |
| 1.3.6.1.4.1.4756.20.732.20.1.890 | Columnf2000EASAddIPRouteRemoteB | read-write | current | f2000EAS Series card IP Routes: Add a new IP Routes : Syntax: [<Interface>] [<network>] [<mask_len>] [<gateway>] [<next_hop_vlan>] Interface : 1~4 |
| 1.3.6.1.4.1.4756.20.732.20.1.891 | Columnf2000EASDeleteIPRouteRemoteB | read-write | current | f2000EAS Series card IP Routes num: Delete a IP Routes num: Syntax: [<Interface>] Interface: 1~4 |
| 1.3.6.1.4.1.4756.20.732.20.1.892 | Columnf2000EASPort1RemotePowerStsRemoteB | read-only | current | f2000EAS Series card Port1 remote Power status 0: None 1: OK 2: Abnormal |
| 1.3.6.1.4.1.4756.20.732.20.1.893 | Columnf2000EASPort2RemotePowerStsRemoteB | read-only | current | f2000EAS Series card Port2 remote Power status 0: None 1: OK 2: Abnormal |
| 1.3.6.1.4.1.4756.20.732.20.1.894 | Columnf2000EASPort3RemotePowerStsRemoteB | read-only | current | f2000EAS Series card Port3 remote Power status 0: None 1: OK 2: Abnormal |
| 1.3.6.1.4.1.4756.20.732.20.1.895 | Columnf2000EASPort4RemotePowerStsRemoteB | read-only | current | f2000EAS Series card Port4 remote Power status 0: None 1: OK 2: Abnormal |
| 1.3.6.1.4.1.4756.20.732.20.1.896 | Columnf2000EASPort1LinkAlarmRemoteB | read-write | current | f2000EAS Series card Port 1 Link alarm: 0: Disable 1: Enable |
| 1.3.6.1.4.1.4756.20.732.20.1.897 | Columnf2000EASPort2LinkAlarmRemoteB | read-write | current | f2000EAS Series card Port 2 Link alarm: 0: Disable 1: Enable |
| 1.3.6.1.4.1.4756.20.732.20.1.898 | Columnf2000EASPort3LinkAlarmRemoteB | read-write | current | f2000EAS Series card Port 3 Link alarm: 0: Disable 1: Enable |
| 1.3.6.1.4.1.4756.20.732.20.1.899 | Columnf2000EASPort4LinkAlarmRemoteB | read-write | current | f2000EAS Series card Port 4 Link alarm: 0: Disable 1: Enable |
| 1.3.6.1.4.1.4756.20.732.20.1.900 | Columnf2000EASAcceptRemoteHWResetRemoteB | read-write | current | f2000EAS Series card Accept Remote H/W Reset: 0: Disable 1: Enable |
| 1.3.6.1.4.1.4756.20.732.20.1.901 | Columnf2000EASRemoteTLPTRemoteB | read-write | current | f2000EAS Series card Remote TLPT: 0: Disable 1: RemoteA 2: RemoteB |
| 1.3.6.1.4.1.4756.20.1000 | NotificationpowerOFF | current | Power 1 or 2 is failed or empty. | |
| 1.3.6.1.4.1.4756.20.1005 | NotificationpowerON | current | Power 1 or 2 is ON. | |
| 1.3.6.1.4.1.4756.20.1010 | NotificationfanOFF | current | Fan 1 or 2 is failed or empty. | |
| 1.3.6.1.4.1.4756.20.1015 | NotificationfanON | current | Fan 1 or 2 is ON. | |
| 1.3.6.1.4.1.4756.20.1020 | NotificationutpLinkDown | current | Any UTP of line card is down. | |
| 1.3.6.1.4.1.4756.20.1025 | NotificationutpLinkUp | current | Any UTP of line card is up. | |
| 1.3.6.1.4.1.4756.20.1030 | NotificationfxLinkDown | current | Any FX of line card is down. | |
| 1.3.6.1.4.1.4756.20.1035 | NotificationfxLinkUp | current | Any FX of line card is up. | |
| 1.3.6.1.4.1.4756.20.1040 | NotificationfefDetect | current | Any FEF of line card is detect. | |
| 1.3.6.1.4.1.4756.20.1045 | NotificationfefUndetect | current | Any FEF of line card is undetect. | |
| 1.3.6.1.4.1.4756.20.1050 | NotificationremotePowerOFF | current | Any remote power of line card OFF. | |
| 1.3.6.1.4.1.4756.20.1055 | NotificationremotePowerON | current | Any remote power of line card ON. | |
| 1.3.6.1.4.1.4756.20.1060 | NotificationlineCardUnplug | current | The line card of either local or remote unpluged. | |
| 1.3.6.1.4.1.4756.20.1065 | NotificationlineCardPlug | current | The line card of either local or remote pluged. | |
| 1.3.6.1.4.1.4756.20.1070 | NotificationalarmModeChg | current | Alarm mode changed. | |
| 1.3.6.1.4.1.4756.20.1080 | NotificationrestoreParameters | current | Restore Line Card Parameters. | |
| 1.3.6.1.4.1.4756.20.1100 | Notificationlogin | current | Somebody login. | |
| 1.3.6.1.4.1.4756.20.1101 | NotificationloginError | current | Somebody login error. | |
| 1.3.6.1.4.1.4756.20.1105 | Notificationlogout | current | Somebody logout. | |
| 1.3.6.1.4.1.4756.20.1110 | NotificationsiganlLoss | current | Siganl Loss. | |
| 1.3.6.1.4.1.4756.20.1115 | NotificationsiganlNormal | current | Siganl Normal. | |
| 1.3.6.1.4.1.4756.20.1160 | NotificationrxPowerNormal | current | Rx Power Normal. | |
| 1.3.6.1.4.1.4756.20.1161 | NotificationrxPowerWarning | current | Rx Power Warning. | |
| 1.3.6.1.4.1.4756.20.1165 | NotificationrxPowerAlarm | current | Rx Power Alarm. | |
| 1.3.6.1.4.1.4756.20.1170 | NotificationsfpPlusQsfpPlusUnLock | current | Sfp+ or QSFP+ CDR unLock. | |
| 1.3.6.1.4.1.4756.20.1175 | NotificationsfpPlusQsfpPlusLock | current | Sfp+ or QSFP+ CDR Lock. | |
| 1.3.6.1.4.1.4756.20.1180 | NotificationsfpPlusQsfpPlusTxFault | current | Sfp+ or QSFP+ Tx Fault. | |
| 1.3.6.1.4.1.4756.20.1190 | NotificationoverTemperature | current | over Temperature. | |
| 1.3.6.1.4.1.4756.20.1200 | NotificationfiberPortSyncLoss | current | Fiber Port Sync Loss. | |
| 1.3.6.1.4.1.4756.20.1205 | NotificationfiberPortSync | current | Fiber Port Sync. | |
| 1.3.6.1.4.1.4756.20.1218 | NotificationsnmpReconfig | current | SNMP Reconfig | |
| 1.3.6.1.4.1.4756.20.1220 | Notificatione1PortSyncLoss | current | E1 Port Sync Loss. | |
| 1.3.6.1.4.1.4756.20.1225 | Notificatione1PortSync | current | E1 Port Sync. | |
| 1.3.6.1.4.1.4756.20.1230 | NotificationsfpPlusQsfpPlusRxFault | current | SFP+ or QSFP+ Rx Fault. | |
| 1.3.6.1.4.1.4756.20.1240 | NotificationinputPowerNormal | current | Input Power Normal. | |
| 1.3.6.1.4.1.4756.20.1241 | NotificationinputPowerWarning | current | Input Power Low Warning. | |
| 1.3.6.1.4.1.4756.20.1242 | NotificationinputPowerAlarm | current | Input Power Loss Alarm. | |
| 1.3.6.1.4.1.4756.20.1245 | NotificationoutputPowerNormal | current | Output Power Normal. | |
| 1.3.6.1.4.1.4756.20.1246 | NotificationoutputPowerWarning | current | Output Power Low Warning. | |
| 1.3.6.1.4.1.4756.20.1247 | NotificationoutputPowerAlarm | current | Output Power Fail Alarm. | |
| 1.3.6.1.4.1.4756.20.1250 | NotificationpowerTempHighAbnormal | current | Case Temperature Abnormal. | |
| 1.3.6.1.4.1.4756.20.1251 | NotificationpowerTempHighNormal | current | Case Temperature Normal. | |
| 1.3.6.1.4.1.4756.20.1252 | NotificationpowerTempAbnormal | current | LD Temperature Abnormal. | |
| 1.3.6.1.4.1.4756.20.1253 | NotificationpowerTempNormal | current | LD Temperature Normal. | |
| 1.3.6.1.4.1.4756.20.1254 | NotificationpowerLDBiasAbnormal | current | LD Current Abnormal. | |
| 1.3.6.1.4.1.4756.20.1255 | NotificationpowerLDBiasNormal | current | LD Current Normal. | |
| 1.3.6.1.4.1.4756.20.1256 | NotificationpowerShutdownAbnormal | current | LD Pump Shutdown. | |
| 1.3.6.1.4.1.4756.20.1257 | NotificationpowerShutdownNormal | current | LD Pump Normal. | |
| 1.3.6.1.4.1.4756.20.1258 | NotificationpowerDefaultAbnormal | current | Default Button Pressed. | |
| 1.3.6.1.4.1.4756.20.1260 | NotificationpowerInputOverAbnormal | current | Input Power Over Limit Alarm. | |
| 1.3.6.1.4.1.4756.20.1261 | NotificationpowerInputOverNormal | current | Input Power Normal. | |
| 1.3.6.1.4.1.4756.20.1262 | NotificationpowerOutputOverAbnormal | current | Output Power Over Limit Alarm. | |
| 1.3.6.1.4.1.4756.20.1263 | NotificationpowerOutputOverNormal | current | Output Power Normal. |