MIB Viewer

CTRON-ENVIRONMENT-MIB

48 objects
No module-level DESCRIPTION found.
Imported Objects
CTRON-MIB-NAMESctenv
RFC-1212OBJECT-TYPE
OIDNameAccessStatusDescription
1.3.6.1.4.1.52.4.1.1.8.1NodechEnv
1.3.6.1.4.1.52.4.1.1.8.1.1ScalarchEnvAmbientTempread-onlymandatoryThe ambient temperature of the room in which the chassis is located. If this sensor is broken or not supported, then this object will be set to zero. The value…
1.3.6.1.4.1.52.4.1.1.8.1.2ScalarchEnvAmbientStatusread-onlymandatoryThis object reflects the status of the ambient temperature reading.
1.3.6.1.4.1.52.4.1.1.8.1.3ScalarchEnvHumidityread-onlymandatoryThe humidity value of the air flowing thru the chassis. The value of this object is the actual humidity * 10.
1.3.6.1.4.1.52.4.1.1.8.1.4ScalarchEnvHumidityStatusread-onlymandatoryThis object reflects the status of the ambient humidity reading.
1.3.6.1.4.1.52.4.1.1.8.1.5ScalarchEnvAmbientHotread-onlymandatoryThe temperature value above which the ambient temperature is deemed to be hot.
1.3.6.1.4.1.52.4.1.1.8.1.6ScalarchEnvAmbientWarmread-onlymandatoryThe temperature value above which the ambient temperature is deemed to be warm, if it is below or equal the hot value.
1.3.6.1.4.1.52.4.1.1.8.1.7ScalarchEnvAmbientCoolread-onlymandatoryThe temperature value below which the ambient temperature is deemed to be cool, if it is above or equal the cold value.
1.3.6.1.4.1.52.4.1.1.8.1.8ScalarchEnvAmbientColdread-onlymandatoryThe temperature value below which the ambient temperature is deemed to be cold.
1.3.6.1.4.1.52.4.1.1.8.1.9ScalarchEnvHumidityMoistread-onlymandatoryThe humidity value above which the chassis humidity is deemed to be moist.
1.3.6.1.4.1.52.4.1.1.8.1.10ScalarchEnvHumidityDryread-onlymandatoryThe humidity value below which the chassis humidity is deemed to be a static risk.
1.3.6.1.4.1.52.4.1.1.8.1.11ScalarchEnvNumFansread-onlymandatoryNumber of fans in a chassis.
1.3.6.1.4.1.52.4.1.1.8.1.12TablechEnvFanTablenot-accessiblemandatoryA list of fans installed in this chassis.
1.3.6.1.4.1.52.4.1.1.8.1.12.1RowchEnvFanEntrynot-accessiblemandatoryA slot entry containing objects for a particular module.
1.3.6.1.4.1.52.4.1.1.8.1.12.1.1ColumnchEnvFanIDread-onlymandatoryA unique value, in the range between 1 and and the value of chEnvNumFans.
1.3.6.1.4.1.52.4.1.1.8.1.12.1.2ColumnchEnvFanStatusread-onlymandatoryThis object reflects the status of the chassis fan.
1.3.6.1.4.1.52.4.1.1.8.1.12.1.3ColumnchEnvFanAdminread-writemandatoryThis object is used to select the operational mode of the fan. If the value is set to 1 (auto) then fan speed is based on temperature. If the value is set to 3…
1.3.6.1.4.1.52.4.1.1.8.1.12.1.4ColumnchEnvFanSpeedread-onlymandatoryThe fan speed expressed as a percentage of the maximum fan speed.
1.3.6.1.4.1.52.4.1.1.8.2NodeboardEnv
1.3.6.1.4.1.52.4.1.1.8.2.1TableboardEnvSlotTablenot-accessiblemandatoryA list of networking modules installed in this chassis.
1.3.6.1.4.1.52.4.1.1.8.2.1.1RowboardEnvSlotEntrynot-accessiblemandatoryA slot entry containing objects for a particular module.
1.3.6.1.4.1.52.4.1.1.8.2.1.1.1ColumnboardEnvSlotIDread-onlymandatoryThe slot number of a chassis slot in which this board is installed. This object is similiar to chSlotID in the Chassis MIB.
1.3.6.1.4.1.52.4.1.1.8.2.1.1.2ColumnboardEnvTempread-onlymandatoryThe temperature of the networking board. If this sensor is broken or not supported, then this object will be set to zero. The temperature is in degrees Fahrenh…
1.3.6.1.4.1.52.4.1.1.8.2.1.1.3ColumnboardEnvTempStatusread-onlymandatoryThis object reflects the status of the board temperature reading.
1.3.6.1.4.1.52.4.1.1.8.2.1.1.4ColumnboardEnvTempRelStatusread-onlymandatoryThis object reflects the status of the board temperature reading relative to the ambient temperature.
1.3.6.1.4.1.52.4.1.1.8.2.1.1.5ColumnboardEnvShutdownAdminread-writemandatoryThis object enables or disables the auto shutdown due to a temperature condition.
1.3.6.1.4.1.52.4.1.1.8.2.1.1.6ColumnboardEnvTempHotread-onlymandatoryThe temperature value above which the board temperature is deemed to be hot.
1.3.6.1.4.1.52.4.1.1.8.2.1.1.7ColumnboardEnvTempWarmread-onlymandatoryThe temperature value above which the board temperature is deemed to be warm, if it is below or equal the hot value.
1.3.6.1.4.1.52.4.1.1.8.2.1.1.8ColumnboardEnvTempCoolread-onlymandatoryThe temperature value below which the board temperature is deemed to be cool, if it is above or equal the cold value.
1.3.6.1.4.1.52.4.1.1.8.2.1.1.9ColumnboardEnvTempColdread-onlymandatoryThe temperature value below which the board temperature is deemed to be cold.
1.3.6.1.4.1.52.4.1.1.8.2.1.1.10ColumnboardEnvTempRelHotread-onlymandatoryThe temperature value above ambient at which the board temperature is deemed to be hot relative to ambient.
1.3.6.1.4.1.52.4.1.1.8.2.1.1.11ColumnboardEnvTempRelWarmread-onlymandatoryThe temperature value above ambient at which the board temperature is deemed to be warm relative to ambient, if it is below the relative hot value of boardEnvT…
1.3.6.1.4.1.52.4.1.1.8.2.1.1.12ColumnboardEnvTempMaxFanRelHotread-onlymandatoryThe temperature value above ambient at which the board temperature is deemed to be hot relative to ambient, with all fans in the chassis running at there maxim…
1.3.6.1.4.1.52.4.1.1.8.2.1.1.13ColumnboardEnvTempMaxFanRelWarmread-onlymandatoryThe temperature value above ambient at which the board temperature is deemed to be warm relative to ambient, if it is below the relative hot value of boardEnvT…
1.3.6.1.4.1.52.4.1.1.8.3NodepsEnv
1.3.6.1.4.1.52.4.1.1.8.3.1TablepsEnvSlotTablenot-accessiblemandatoryA list of networking modules installed in this chassis.
1.3.6.1.4.1.52.4.1.1.8.3.1.1RowpsEnvSlotEntrynot-accessiblemandatoryA slot entry containing objects for a particular module.
1.3.6.1.4.1.52.4.1.1.8.3.1.1.1ColumnpsEnvSlotIDread-onlymandatoryThe slot number of a chassis slot in which this power supply is installed. An unique value, in the range between 1 and and the value of chNumSlots. This object…
1.3.6.1.4.1.52.4.1.1.8.3.1.1.2ColumnpsEnvTempread-onlymandatoryThe temperature of the power supply. If this sensor is broken or not supported, then this object will be set to zero. The temperature is in degrees Fahrenheit …
1.3.6.1.4.1.52.4.1.1.8.3.1.1.3ColumnpsEnvTempStatusread-onlymandatoryThis object reflects the status of the power supply temperature reading.
1.3.6.1.4.1.52.4.1.1.8.3.1.1.4ColumnpsEnvTempHotread-onlymandatoryThe temperature value above which the power supply temperature is deemed to be hot.
1.3.6.1.4.1.52.4.1.1.8.3.1.1.5ColumnpsEnvTempWarmread-onlymandatoryThe temperature value above which the power supply temperature is deemed to be warm, if it is below or equal the hot value.
1.3.6.1.4.1.52.4.1.1.8.3.1.1.6ColumnpsEnvTempCoolread-onlymandatoryThe temperature value below which the power supply temperature is deemed to be cool, if it is above or equal the cold value.
1.3.6.1.4.1.52.4.1.1.8.3.1.1.7ColumnpsEnvTempColdread-onlymandatoryThe temperature value below which the power supply temperature is deemed to be cold.
1.3.6.1.4.1.52.4.1.1.8.3.1.1.8ColumnpsEnvFanStatusread-onlymandatoryThis object reflects the status of the chassis fan.
1.3.6.1.4.1.52.4.1.1.8.3.1.1.9ColumnpsEnvFanAdminread-writemandatoryThis object is used to select the operational mode of the fan. If the value is set to 1 (auto) then fan speed is based on temperature. If the value is set to 3…
1.3.6.1.4.1.52.4.1.1.8.3.1.1.10ColumnpsEnvFanSpeedread-onlymandatoryThe fan speed expressed as a percentage of the maximum fan speed.
1.3.6.1.4.1.52.4.1.1.8.4NodebbuEnv