MIB Viewer

CTRON-FDDI-FNB-MIB

69 objects
No module-level DESCRIPTION found.
OIDNameAccessStatusDescription
1.3.6.1.4.1.52.4.1.2.5.1.1NodectFDDIResource
1.3.6.1.4.1.52.4.1.2.5.1.1.1TablectFDDIResourceTablenot-accessiblemandatoryThis table specifies the physical resources associated with the FNB and general FNB operation for a particular module in a particular slot.
1.3.6.1.4.1.52.4.1.2.5.1.1.1.1RowctFDDIResourceEntrynot-accessiblemandatoryDefines a specific physical resource entry
1.3.6.1.4.1.52.4.1.2.5.1.1.1.1.1ColumnctFDDIResourceSlotIDread-onlymandatoryA specific instance of a slot as defined by chSlotID as defined in the chassis MIB.
1.3.6.1.4.1.52.4.1.2.5.1.1.1.1.2ColumnctFDDIResourceIDread-onlymandatoryA unique index that defines a specific physcial resource for which this relationship exists. The value of this is as defined by chResourceID in the chassis MIB.
1.3.6.1.4.1.52.4.1.2.5.1.1.1.1.3ColumnctFDDIResourceTyperead-onlymandatoryDefines the type of resource. This is the same value as chResourceType in the chassis MIB.
1.3.6.1.4.1.52.4.1.2.5.1.1.1.1.4ColumnctFDDIResourceNumbInstanceread-onlymandatoryThis object defines the number of instances of a physical resource. Specific resource instances are physically located from top-to-bottom on a particular modul…
1.3.6.1.4.1.52.4.1.2.5.1.2NodectFDDINonMux
1.3.6.1.4.1.52.4.1.2.5.1.2.1TablectFDDINonMuxCapTablenot-accessiblemandatoryThis table describes all possible capabilities/configurations for all non-muxed FDDI configurations within the chassis.
1.3.6.1.4.1.52.4.1.2.5.1.2.1.1RowctFDDINonMuxCapEntrynot-accessiblemandatoryDescribes a particular capability/configuration entry.
1.3.6.1.4.1.52.4.1.2.5.1.2.1.1.1ColumnctFDDINMSlotread-onlymandatoryThe slot within the chassis for which this configuration information is defined.
1.3.6.1.4.1.52.4.1.2.5.1.2.1.1.2ColumnctFDDINMConfigIDread-onlymandatoryThe instance of a particular configuration.
1.3.6.1.4.1.52.4.1.2.5.1.2.1.1.3ColumnctFDDINMConfigread-onlymandatoryThis object defines a specific valid connection configuration. It will specify the connection state of all resource instances. If an instance of a resource is …
1.3.6.1.4.1.52.4.1.2.5.1.2.1.1.4ColumnctFDDINMConfigDescread-onlymandatoryThis object contains a textual description of a valid connection configuration. This is a more user-friendly representation of the configuration than the ctFDD…
1.3.6.1.4.1.52.4.1.2.5.1.2.2TablectFDDINonMuxCapEnableTablenot-accessiblemandatoryThis table describes the currently enabled configuration for each module.
1.3.6.1.4.1.52.4.1.2.5.1.2.2.1RowctFDDINonMuxCapEnableEntrynot-accessiblemandatoryDescribes a specific configuration enable entry.
1.3.6.1.4.1.52.4.1.2.5.1.2.2.1.1ColumnctFDDINMEnableSlotread-onlymandatoryA specific slot for which this configuration enable pertains.
1.3.6.1.4.1.52.4.1.2.5.1.2.2.1.2ColumnctFDDINMCapEnableread-writemandatoryA specific configuration that is enabled. Enabling a configuration is done by writing the value of ctFDDINMConfigID for a specific configuration to this object…
1.3.6.1.4.1.52.4.1.2.5.1.2.3TablectFDDINonMuxConnectionTablenot-accessiblemandatoryThis table defines specific information for each defined FDDI/FNB connection. This maps the third sub identifier of ctFDDINMConfig to a particular SMT and MAC …
1.3.6.1.4.1.52.4.1.2.5.1.2.3.1RowctFDDINonMuxConnectionEntrynot-accessiblemandatoryDefines a specific configuration connection entry.
1.3.6.1.4.1.52.4.1.2.5.1.2.3.1.1ColumnctFDDINMConnectionSlotread-onlymandatoryA specific slot for which this connection entry is defined.
1.3.6.1.4.1.52.4.1.2.5.1.2.3.1.2ColumnctFDDINMConnectionIDread-onlymandatoryDescribes a specific connection identifier. Valid connection identifiers are defined by the third sub-identifier in ctFDDINMConfig as identified by ctFDDINMCap…
1.3.6.1.4.1.52.4.1.2.5.1.2.3.1.3ColumnctFDDINMSMTread-onlymandatoryA specific instance of SMT for which this entry pertains.
1.3.6.1.4.1.52.4.1.2.5.1.2.3.1.4ColumnctFDDINMMACread-onlymandatoryA specific MAC that this connection entry pertains.
1.3.6.1.4.1.52.4.1.2.5.1.2.3.1.5ColumnctFDDINMBytesread-onlymandatoryThe bandwidth utilization in bytes per second.
1.3.6.1.4.1.52.4.1.2.5.1.2.3.1.6ColumnctFDDINMFramesread-onlymandatoryThe bandwidth utilization in frames per second.
1.3.6.1.4.1.52.4.1.2.5.1.2.4TablectFDDINonMuxInterfaceTablenot-accessiblemandatoryThis table describs the number of interfaces defined by each non multiplexing FDDI FNB module.
1.3.6.1.4.1.52.4.1.2.5.1.2.4.1RowctFDDINonMuxInterfaceEntrynot-accessiblemandatoryA specfic non multiplexing module interface definition.
1.3.6.1.4.1.52.4.1.2.5.1.2.4.1.1ColumnctFDDINMInterSlotread-onlymandatoryA specific slot for which this inteface entry is defined.
1.3.6.1.4.1.52.4.1.2.5.1.2.4.1.2ColumnctFDDINMNumbInterfacesread-onlymandatoryThe number of interfaces defined on this particular module.
1.3.6.1.4.1.52.4.1.2.5.1.3NodectFDDIMux
1.3.6.1.4.1.52.4.1.2.5.1.3.1TablectFDDIMuxCapTablenot-accessiblemandatoryThis table describes all possible configuration/capabilities defined for a FDDI multiplexing module.
1.3.6.1.4.1.52.4.1.2.5.1.3.1.1RowctFDDIMuxCapEntrynot-accessiblemandatoryDescribes a specfic FDDI multiplexor capability/configuration entry.
1.3.6.1.4.1.52.4.1.2.5.1.3.1.1.1ColumnctFDDIMuxSlotread-onlymandatoryDefines the slot within the chassis for which this multiplexed capability/configuration entry pertains.
1.3.6.1.4.1.52.4.1.2.5.1.3.1.1.2ColumnctFDDIMuxConfigIDread-onlymandatoryThe instance of a particular configuration.
1.3.6.1.4.1.52.4.1.2.5.1.3.1.1.3ColumnctFDDIMuxConfigread-onlymandatoryThis object defines a specific valid connection configuration. It will specify the connection state of all resource instances. If an instance of a resource is …
1.3.6.1.4.1.52.4.1.2.5.1.3.1.1.4ColumnctFDDIMuxConfigDescread-onlymandatoryThis object contains a textual description of a valid connection configuration. This is a more user-friendly representation of the configuration than the ctFDD…
1.3.6.1.4.1.52.4.1.2.5.1.3.2TablectFDDIMuxCapEnableTablenot-accessiblemandatoryThis table describes the currently enabled configuration for each module.
1.3.6.1.4.1.52.4.1.2.5.1.3.2.1RowctFDDIMuxCapEnableEntrynot-accessiblemandatoryDescribes a specific configuration enable entry.
1.3.6.1.4.1.52.4.1.2.5.1.3.2.1.1ColumnctFDDIMuxEnableSlotread-onlymandatoryA specific slot for which this configuration enable pertains.
1.3.6.1.4.1.52.4.1.2.5.1.3.2.1.2ColumnctFDDIMuxCapEnableread-writemandatoryA specific instance of the configuration that is enabled. Setting this object with a specific value of ctFDDIMuxConfigID enabled that configuration. A request …
1.3.6.1.4.1.52.4.1.2.5.1.3.2.1.3ColumnctFDDIMuxMasterPortAssignmentChangeread-onlymandatoryDepicts the number of changes to the master port to multiplexor output mapping.
1.3.6.1.4.1.52.4.1.2.5.1.3.3TablectFDDIMuxOutTablenot-accessiblemandatoryDescribes the multiplexor outputs for each of the FNB multiplexor modules. This maps the multiplexor output to a specific instance of MAC and SMT in the FDDI M…
1.3.6.1.4.1.52.4.1.2.5.1.3.3.1RowctFDDIMuxOutEntrynot-accessiblemandatoryDescribes a particular multiplexor output.
1.3.6.1.4.1.52.4.1.2.5.1.3.3.1.1ColumnctFDDIMuxOutSlotread-onlymandatoryThe given slot for which this multiplexor output information pertains.
1.3.6.1.4.1.52.4.1.2.5.1.3.3.1.2ColumnctFDDIMuxOutIDread-onlymandatoryThe specific instance of the multiplexor output. Instances of this object are used by the values of ctFDDIMuxConfig.
1.3.6.1.4.1.52.4.1.2.5.1.3.3.1.3ColumnctFDDIMuxOutMACIndexread-onlymandatoryThe MAC instance of this multiplexor output. If this this object has a value greater than 0, then this value is the same as fddimibMACIndex. If this object has…
1.3.6.1.4.1.52.4.1.2.5.1.3.3.1.4ColumnctFDDIMuxOutSMTIndexread-onlymandatoryIdentifies the instance of SMT as defined within the FDDI MIB.
1.3.6.1.4.1.52.4.1.2.5.1.3.3.1.5ColumnctFDDIMuxBytesread-onlymandatoryThe bandwidth utilization in bytes per second.
1.3.6.1.4.1.52.4.1.2.5.1.3.3.1.6ColumnctFDDIMuxFramesread-onlymandatoryThe bandwidth utilization in frames per second.
1.3.6.1.4.1.52.4.1.2.5.1.3.4TablectFDDIMuxMasterPortTablenot-accessiblemandatoryA list of entries that define master ports as they are defined for the given multiplexed FDDI connection.
1.3.6.1.4.1.52.4.1.2.5.1.3.4.1RowctFDDIMuxMasterPortEntrynot-accessiblemandatoryA specific FDDI-FNB multiplexed master port definition.
1.3.6.1.4.1.52.4.1.2.5.1.3.4.1.1ColumnctFDDIMuxMasterPortSlotIDread-onlymandatoryA specific instance of a slot as defined by chSlotID.
1.3.6.1.4.1.52.4.1.2.5.1.3.4.1.2ColumnctFDDIMuxMasterPortIDread-onlymandatoryA unique identifier for this specific master port.
1.3.6.1.4.1.52.4.1.2.5.1.3.4.1.3ColumnctFDDIMuxMasterPortAssignmentread-writemandatoryProvides the masterport to multiplexor output mapping. This is as defined by ctFDDIMuxOutMacAssignment.
1.3.6.1.4.1.52.4.1.2.5.1.3.4.1.4ColumnctFDDIMuxMasterPortIndexread-onlymandatoryDefines a specific port within the FDDI MIBs fddimibPORTTable.
1.3.6.1.4.1.52.4.1.2.5.1.4NodectFDDISerialConfig
1.3.6.1.4.1.52.4.1.2.5.1.4.1ScalarctFDDINumbModulesread-onlymandatoryDescribes the number of modules that are present configurable thru the serial control portion of this MIB. This directly reflects the number of rows found with…
1.3.6.1.4.1.52.4.1.2.5.1.4.2TablectFDDISerialConfigTablenot-accessiblemandatoryThis table describes the adminstrative control over each of the FNB serial control modules.
1.3.6.1.4.1.52.4.1.2.5.1.4.2.1RowctFDDISerialConfigEntrynot-accessiblemandatoryDescribes the controls over a single FNB serial control entry.
1.3.6.1.4.1.52.4.1.2.5.1.4.2.1.1ColumnctFDDISerialSlotIDread-onlymandatoryDefines the slot that this FNB serial control module is in. This is an instance of chSlotID as defined in the chassis MIB.
1.3.6.1.4.1.52.4.1.2.5.1.4.2.1.2ColumnctFDDISerialAdminStatusread-writemandatoryDescribes the adminstrative desired state for this FNB serial control module. insertFNB1(1) - The serial controlled module should be inserted into FNB-1 and by…
1.3.6.1.4.1.52.4.1.2.5.1.4.2.1.3ColumnctFDDISerialOperStatusread-onlymandatoryDescribes the operational status of this FDDI serial controlled module. insertFNB1(1) - The serial controlled module is inserted into FNB-1 and bypassed from F…
1.3.6.1.4.1.52.4.1.2.5.1.4.3TablectFDDIModuleFPIMTablenot-accessiblemandatoryThis table describes the FPIMs that are on the front panel of each FDDI serial control module, if that module supports FPIMs.
1.3.6.1.4.1.52.4.1.2.5.1.4.3.1RowctFDDIModuleFPIMEntrynot-accessiblemandatoryDescribes a single FDDI FPIM on a module.
1.3.6.1.4.1.52.4.1.2.5.1.4.3.1.1ColumnctFddiFPIMSlotIDread-onlymandatoryDefines the slot in which this module exists. This is an instance of chSlotID as found in the chassis MIB.
1.3.6.1.4.1.52.4.1.2.5.1.4.3.1.2ColumnctFddiFPIMread-onlymandatoryDefines the instance of the port for which this definition is made. Ports are physically located from top-to-bottom on a particular module. If there are multip…
1.3.6.1.4.1.52.4.1.2.5.1.4.3.1.4ColumnctFddiFPIMStatusread-onlymandatoryDescribes the link status of the given FPIM. A value of link(1) states that a link is present. A value of noLink(2) states that no link is present. A value of …
1.3.6.1.4.1.52.4.1.2.5.1.4.3.1.5ColumnctFddiFPIMTyperead-onlymandatoryDescribes the type of FPIM as found in ctron-oids.