CTRON-FDDI-FNB-MIB
69 objects
No module-level DESCRIPTION found.
Imported Objects
| CTRON-MIB-NAMES | ctFDDIFnb |
| RFC-1212 | OBJECT-TYPE |
| RFC1155-SMI | Counter |
| RFC1213-MIB | DisplayString |
| OID | Name | Access | Status | Description |
|---|---|---|---|---|
| 1.3.6.1.4.1.52.4.1.2.5.1.1 | NodectFDDIResource | |||
| 1.3.6.1.4.1.52.4.1.2.5.1.1.1 | TablectFDDIResourceTable | not-accessible | mandatory | This table specifies the physical resources associated with the FNB and general FNB operation for a particular module in a particular slot. |
| 1.3.6.1.4.1.52.4.1.2.5.1.1.1.1 | RowctFDDIResourceEntry | not-accessible | mandatory | Defines a specific physical resource entry |
| 1.3.6.1.4.1.52.4.1.2.5.1.1.1.1.1 | ColumnctFDDIResourceSlotID | read-only | mandatory | A specific instance of a slot as defined by chSlotID as defined in the chassis MIB. |
| 1.3.6.1.4.1.52.4.1.2.5.1.1.1.1.2 | ColumnctFDDIResourceID | read-only | mandatory | A unique index that defines a specific physcial resource for which this relationship exists. The value of this is as defined by chResourceID in the chassis MIB. |
| 1.3.6.1.4.1.52.4.1.2.5.1.1.1.1.3 | ColumnctFDDIResourceType | read-only | mandatory | Defines the type of resource. This is the same value as chResourceType in the chassis MIB. |
| 1.3.6.1.4.1.52.4.1.2.5.1.1.1.1.4 | ColumnctFDDIResourceNumbInstance | read-only | mandatory | This object defines the number of instances of a physical resource. Specific resource instances are physically located from top-to-bottom on a particular modul… |
| 1.3.6.1.4.1.52.4.1.2.5.1.2 | NodectFDDINonMux | |||
| 1.3.6.1.4.1.52.4.1.2.5.1.2.1 | TablectFDDINonMuxCapTable | not-accessible | mandatory | This table describes all possible capabilities/configurations for all non-muxed FDDI configurations within the chassis. |
| 1.3.6.1.4.1.52.4.1.2.5.1.2.1.1 | RowctFDDINonMuxCapEntry | not-accessible | mandatory | Describes a particular capability/configuration entry. |
| 1.3.6.1.4.1.52.4.1.2.5.1.2.1.1.1 | ColumnctFDDINMSlot | read-only | mandatory | The slot within the chassis for which this configuration information is defined. |
| 1.3.6.1.4.1.52.4.1.2.5.1.2.1.1.2 | ColumnctFDDINMConfigID | read-only | mandatory | The instance of a particular configuration. |
| 1.3.6.1.4.1.52.4.1.2.5.1.2.1.1.3 | ColumnctFDDINMConfig | read-only | mandatory | This object defines a specific valid connection configuration. It will specify the connection state of all resource instances. If an instance of a resource is … |
| 1.3.6.1.4.1.52.4.1.2.5.1.2.1.1.4 | ColumnctFDDINMConfigDesc | read-only | mandatory | This object contains a textual description of a valid connection configuration. This is a more user-friendly representation of the configuration than the ctFDD… |
| 1.3.6.1.4.1.52.4.1.2.5.1.2.2 | TablectFDDINonMuxCapEnableTable | not-accessible | mandatory | This table describes the currently enabled configuration for each module. |
| 1.3.6.1.4.1.52.4.1.2.5.1.2.2.1 | RowctFDDINonMuxCapEnableEntry | not-accessible | mandatory | Describes a specific configuration enable entry. |
| 1.3.6.1.4.1.52.4.1.2.5.1.2.2.1.1 | ColumnctFDDINMEnableSlot | read-only | mandatory | A specific slot for which this configuration enable pertains. |
| 1.3.6.1.4.1.52.4.1.2.5.1.2.2.1.2 | ColumnctFDDINMCapEnable | read-write | mandatory | A specific configuration that is enabled. Enabling a configuration is done by writing the value of ctFDDINMConfigID for a specific configuration to this object… |
| 1.3.6.1.4.1.52.4.1.2.5.1.2.3 | TablectFDDINonMuxConnectionTable | not-accessible | mandatory | This table defines specific information for each defined FDDI/FNB connection. This maps the third sub identifier of ctFDDINMConfig to a particular SMT and MAC … |
| 1.3.6.1.4.1.52.4.1.2.5.1.2.3.1 | RowctFDDINonMuxConnectionEntry | not-accessible | mandatory | Defines a specific configuration connection entry. |
| 1.3.6.1.4.1.52.4.1.2.5.1.2.3.1.1 | ColumnctFDDINMConnectionSlot | read-only | mandatory | A specific slot for which this connection entry is defined. |
| 1.3.6.1.4.1.52.4.1.2.5.1.2.3.1.2 | ColumnctFDDINMConnectionID | read-only | mandatory | Describes a specific connection identifier. Valid connection identifiers are defined by the third sub-identifier in ctFDDINMConfig as identified by ctFDDINMCap… |
| 1.3.6.1.4.1.52.4.1.2.5.1.2.3.1.3 | ColumnctFDDINMSMT | read-only | mandatory | A specific instance of SMT for which this entry pertains. |
| 1.3.6.1.4.1.52.4.1.2.5.1.2.3.1.4 | ColumnctFDDINMMAC | read-only | mandatory | A specific MAC that this connection entry pertains. |
| 1.3.6.1.4.1.52.4.1.2.5.1.2.3.1.5 | ColumnctFDDINMBytes | read-only | mandatory | The bandwidth utilization in bytes per second. |
| 1.3.6.1.4.1.52.4.1.2.5.1.2.3.1.6 | ColumnctFDDINMFrames | read-only | mandatory | The bandwidth utilization in frames per second. |
| 1.3.6.1.4.1.52.4.1.2.5.1.2.4 | TablectFDDINonMuxInterfaceTable | not-accessible | mandatory | This table describs the number of interfaces defined by each non multiplexing FDDI FNB module. |
| 1.3.6.1.4.1.52.4.1.2.5.1.2.4.1 | RowctFDDINonMuxInterfaceEntry | not-accessible | mandatory | A specfic non multiplexing module interface definition. |
| 1.3.6.1.4.1.52.4.1.2.5.1.2.4.1.1 | ColumnctFDDINMInterSlot | read-only | mandatory | A specific slot for which this inteface entry is defined. |
| 1.3.6.1.4.1.52.4.1.2.5.1.2.4.1.2 | ColumnctFDDINMNumbInterfaces | read-only | mandatory | The number of interfaces defined on this particular module. |
| 1.3.6.1.4.1.52.4.1.2.5.1.3 | NodectFDDIMux | |||
| 1.3.6.1.4.1.52.4.1.2.5.1.3.1 | TablectFDDIMuxCapTable | not-accessible | mandatory | This table describes all possible configuration/capabilities defined for a FDDI multiplexing module. |
| 1.3.6.1.4.1.52.4.1.2.5.1.3.1.1 | RowctFDDIMuxCapEntry | not-accessible | mandatory | Describes a specfic FDDI multiplexor capability/configuration entry. |
| 1.3.6.1.4.1.52.4.1.2.5.1.3.1.1.1 | ColumnctFDDIMuxSlot | read-only | mandatory | Defines the slot within the chassis for which this multiplexed capability/configuration entry pertains. |
| 1.3.6.1.4.1.52.4.1.2.5.1.3.1.1.2 | ColumnctFDDIMuxConfigID | read-only | mandatory | The instance of a particular configuration. |
| 1.3.6.1.4.1.52.4.1.2.5.1.3.1.1.3 | ColumnctFDDIMuxConfig | read-only | mandatory | This object defines a specific valid connection configuration. It will specify the connection state of all resource instances. If an instance of a resource is … |
| 1.3.6.1.4.1.52.4.1.2.5.1.3.1.1.4 | ColumnctFDDIMuxConfigDesc | read-only | mandatory | This object contains a textual description of a valid connection configuration. This is a more user-friendly representation of the configuration than the ctFDD… |
| 1.3.6.1.4.1.52.4.1.2.5.1.3.2 | TablectFDDIMuxCapEnableTable | not-accessible | mandatory | This table describes the currently enabled configuration for each module. |
| 1.3.6.1.4.1.52.4.1.2.5.1.3.2.1 | RowctFDDIMuxCapEnableEntry | not-accessible | mandatory | Describes a specific configuration enable entry. |
| 1.3.6.1.4.1.52.4.1.2.5.1.3.2.1.1 | ColumnctFDDIMuxEnableSlot | read-only | mandatory | A specific slot for which this configuration enable pertains. |
| 1.3.6.1.4.1.52.4.1.2.5.1.3.2.1.2 | ColumnctFDDIMuxCapEnable | read-write | mandatory | A specific instance of the configuration that is enabled. Setting this object with a specific value of ctFDDIMuxConfigID enabled that configuration. A request … |
| 1.3.6.1.4.1.52.4.1.2.5.1.3.2.1.3 | ColumnctFDDIMuxMasterPortAssignmentChange | read-only | mandatory | Depicts the number of changes to the master port to multiplexor output mapping. |
| 1.3.6.1.4.1.52.4.1.2.5.1.3.3 | TablectFDDIMuxOutTable | not-accessible | mandatory | Describes the multiplexor outputs for each of the FNB multiplexor modules. This maps the multiplexor output to a specific instance of MAC and SMT in the FDDI M… |
| 1.3.6.1.4.1.52.4.1.2.5.1.3.3.1 | RowctFDDIMuxOutEntry | not-accessible | mandatory | Describes a particular multiplexor output. |
| 1.3.6.1.4.1.52.4.1.2.5.1.3.3.1.1 | ColumnctFDDIMuxOutSlot | read-only | mandatory | The given slot for which this multiplexor output information pertains. |
| 1.3.6.1.4.1.52.4.1.2.5.1.3.3.1.2 | ColumnctFDDIMuxOutID | read-only | mandatory | The specific instance of the multiplexor output. Instances of this object are used by the values of ctFDDIMuxConfig. |
| 1.3.6.1.4.1.52.4.1.2.5.1.3.3.1.3 | ColumnctFDDIMuxOutMACIndex | read-only | mandatory | The MAC instance of this multiplexor output. If this this object has a value greater than 0, then this value is the same as fddimibMACIndex. If this object has… |
| 1.3.6.1.4.1.52.4.1.2.5.1.3.3.1.4 | ColumnctFDDIMuxOutSMTIndex | read-only | mandatory | Identifies the instance of SMT as defined within the FDDI MIB. |
| 1.3.6.1.4.1.52.4.1.2.5.1.3.3.1.5 | ColumnctFDDIMuxBytes | read-only | mandatory | The bandwidth utilization in bytes per second. |
| 1.3.6.1.4.1.52.4.1.2.5.1.3.3.1.6 | ColumnctFDDIMuxFrames | read-only | mandatory | The bandwidth utilization in frames per second. |
| 1.3.6.1.4.1.52.4.1.2.5.1.3.4 | TablectFDDIMuxMasterPortTable | not-accessible | mandatory | A list of entries that define master ports as they are defined for the given multiplexed FDDI connection. |
| 1.3.6.1.4.1.52.4.1.2.5.1.3.4.1 | RowctFDDIMuxMasterPortEntry | not-accessible | mandatory | A specific FDDI-FNB multiplexed master port definition. |
| 1.3.6.1.4.1.52.4.1.2.5.1.3.4.1.1 | ColumnctFDDIMuxMasterPortSlotID | read-only | mandatory | A specific instance of a slot as defined by chSlotID. |
| 1.3.6.1.4.1.52.4.1.2.5.1.3.4.1.2 | ColumnctFDDIMuxMasterPortID | read-only | mandatory | A unique identifier for this specific master port. |
| 1.3.6.1.4.1.52.4.1.2.5.1.3.4.1.3 | ColumnctFDDIMuxMasterPortAssignment | read-write | mandatory | Provides the masterport to multiplexor output mapping. This is as defined by ctFDDIMuxOutMacAssignment. |
| 1.3.6.1.4.1.52.4.1.2.5.1.3.4.1.4 | ColumnctFDDIMuxMasterPortIndex | read-only | mandatory | Defines a specific port within the FDDI MIBs fddimibPORTTable. |
| 1.3.6.1.4.1.52.4.1.2.5.1.4 | NodectFDDISerialConfig | |||
| 1.3.6.1.4.1.52.4.1.2.5.1.4.1 | ScalarctFDDINumbModules | read-only | mandatory | Describes the number of modules that are present configurable thru the serial control portion of this MIB. This directly reflects the number of rows found with… |
| 1.3.6.1.4.1.52.4.1.2.5.1.4.2 | TablectFDDISerialConfigTable | not-accessible | mandatory | This table describes the adminstrative control over each of the FNB serial control modules. |
| 1.3.6.1.4.1.52.4.1.2.5.1.4.2.1 | RowctFDDISerialConfigEntry | not-accessible | mandatory | Describes the controls over a single FNB serial control entry. |
| 1.3.6.1.4.1.52.4.1.2.5.1.4.2.1.1 | ColumnctFDDISerialSlotID | read-only | mandatory | Defines the slot that this FNB serial control module is in. This is an instance of chSlotID as defined in the chassis MIB. |
| 1.3.6.1.4.1.52.4.1.2.5.1.4.2.1.2 | ColumnctFDDISerialAdminStatus | read-write | mandatory | Describes the adminstrative desired state for this FNB serial control module. insertFNB1(1) - The serial controlled module should be inserted into FNB-1 and by… |
| 1.3.6.1.4.1.52.4.1.2.5.1.4.2.1.3 | ColumnctFDDISerialOperStatus | read-only | mandatory | Describes the operational status of this FDDI serial controlled module. insertFNB1(1) - The serial controlled module is inserted into FNB-1 and bypassed from F… |
| 1.3.6.1.4.1.52.4.1.2.5.1.4.3 | TablectFDDIModuleFPIMTable | not-accessible | mandatory | This table describes the FPIMs that are on the front panel of each FDDI serial control module, if that module supports FPIMs. |
| 1.3.6.1.4.1.52.4.1.2.5.1.4.3.1 | RowctFDDIModuleFPIMEntry | not-accessible | mandatory | Describes a single FDDI FPIM on a module. |
| 1.3.6.1.4.1.52.4.1.2.5.1.4.3.1.1 | ColumnctFddiFPIMSlotID | read-only | mandatory | Defines the slot in which this module exists. This is an instance of chSlotID as found in the chassis MIB. |
| 1.3.6.1.4.1.52.4.1.2.5.1.4.3.1.2 | ColumnctFddiFPIM | read-only | mandatory | Defines the instance of the port for which this definition is made. Ports are physically located from top-to-bottom on a particular module. If there are multip… |
| 1.3.6.1.4.1.52.4.1.2.5.1.4.3.1.4 | ColumnctFddiFPIMStatus | read-only | mandatory | Describes the link status of the given FPIM. A value of link(1) states that a link is present. A value of noLink(2) states that no link is present. A value of … |
| 1.3.6.1.4.1.52.4.1.2.5.1.4.3.1.5 | ColumnctFddiFPIMType | read-only | mandatory | Describes the type of FPIM as found in ctron-oids. |