CTTRAPLOG-MIB
35 objects
No module-level DESCRIPTION found.
Imported Objects
| CTRON-MIB-NAMES | ctTrapLog |
| RFC-1212 | OBJECT-TYPE |
| RFC1155-SMI | Counter TimeTicks |
| RFC1213-MIB | DisplayString |
| OID | Name | Access | Status | Description |
|---|---|---|---|---|
| 1.3.6.1.4.1.52.4.1.44.1 | ScalartotalNumberOfEntries | read-only | mandatory | Total number of logged entries for this chassis. |
| 1.3.6.1.4.1.52.4.1.44.2 | TableconfigTable | not-accessible | mandatory | |
| 1.3.6.1.4.1.52.4.1.44.2.1 | RowconfigTableEntry | not-accessible | mandatory | Each entry allows a user to configure the alarm table for a specific slot. Objects such as Current Entry, MaxEntries Allowed, and an Enable/Disable switch are … |
| 1.3.6.1.4.1.52.4.1.44.2.1.1 | ColumnslotInChassis | read-only | mandatory | Each Slot can be separately configured. This is the slot number for the configuration entry. |
| 1.3.6.1.4.1.52.4.1.44.2.1.2 | ColumnnumEntriesLoggeds | read-only | mandatory | This is the total number of entries looged for this slot. |
| 1.3.6.1.4.1.52.4.1.44.2.1.3 | ColumnnumEntriesRequested | read-write | mandatory | Maximum number of entries to store before wrapping the log on this slot. |
| 1.3.6.1.4.1.52.4.1.44.2.1.4 | ColumnnumEntriesAllocated | read-only | mandatory | This is the number of entries allocated to log alarms on this slot. It will always be less than or equal to the requested number of entries. |
| 1.3.6.1.4.1.52.4.1.44.2.1.5 | ColumnlastLoggedEntryLogId | read-only | mandatory | This is the log id of the last entry logged for this slot. |
| 1.3.6.1.4.1.52.4.1.44.2.1.6 | ColumnlogCommand | read-write | mandatory | Allows the user to send the log the commands specified in the enumeration. |
| 1.3.6.1.4.1.52.4.1.44.2.1.7 | Columnwrap | read-only | mandatory | This is whether or not this configuration has wrapped or not. |
| 1.3.6.1.4.1.52.4.1.44.3 | TabletrapLogTable | not-accessible | mandatory | |
| 1.3.6.1.4.1.52.4.1.44.3.1 | RowtrapLogEntry | not-accessible | mandatory | Each alarm entry is generated from one of the following sources; (1) a module in one of the main chassis slots, (2) the EM, (3) or a power supply. |
| 1.3.6.1.4.1.52.4.1.44.3.1.1 | ColumnlogId | read-only | mandatory | Each slot has a maximium number of log entries that it can support. Each entry is assigned a monotonically increasing sequence number. When the maximum number … |
| 1.3.6.1.4.1.52.4.1.44.3.1.2 | ColumnnvmpId | read-only | mandatory | This contains the nvmp id of the trap that occurred. |
| 1.3.6.1.4.1.52.4.1.44.3.1.3 | ColumntrapLogAcknowledged | read-only | mandatory | This field is set to 2 if a trap as been acknowledged from the EM. |
| 1.3.6.1.4.1.52.4.1.44.3.1.4 | ColumntrapLogVarBind | read-only | mandatory | This is an ASN.1 encoded string representing the pairs of OID/value items supplied in the original SNMP or NVMP trap. |
| 1.3.6.1.4.1.52.4.1.44.3.1.5 | ColumntrapLogDescription | read-only | mandatory | This is an internally defined string used to describe an alarm. Its primary use is for display on the EMs LCD. A default value will be used for the old trap ca… |
| 1.3.6.1.4.1.52.4.1.44.3.1.6 | ColumntimeLogged | read-only | mandatory | The time the entry was logged. This will be date and time if possible. |
| 1.3.6.1.4.1.52.4.1.44.3.1.7 | ColumnfilterId | read-only | mandatory | This will be used to filter certain alarms. The criteria is TBD. An example of classification: informational - requires no intervention. warning - Does not req… |
| 1.3.6.1.4.1.52.4.1.44.3.1.8 | ColumnslotChassis | read-only | mandatory | Slot of this trap log. |
| 1.3.6.1.4.1.52.4.1.44.3.1.9 | ColumntrapOID | read-only | mandatory | This OID combines the General Trap code, Specific Trap code, and the sys object id into one OID. |
| 1.3.6.1.4.1.52.4.1.44.3.1.10 | Columnz80Time | read-only | mandatory | This is the time that the Z80 has been up for the board that sent this trap. |
| 1.3.6.1.4.1.52.4.1.44.4 | TablefilterTable | not-accessible | mandatory | |
| 1.3.6.1.4.1.52.4.1.44.4.1 | RowfilterEntry | not-accessible | mandatory | Each filter entry is generated from one of the following sources; (1) a module in one of the main chassis slots, (2) the EM, (3) or a power supply. |
| 1.3.6.1.4.1.52.4.1.44.4.1.1 | ColumnfilterLogId | read-only | mandatory | Each slot has a maximum number of log entries that it can support. Each entry is assigned a monotonically increasing sequence number. When the maximum number o… |
| 1.3.6.1.4.1.52.4.1.44.4.1.2 | ColumnfilterNvmpId | read-only | mandatory | This contains the nvmp id of the trap that was generated. |
| 1.3.6.1.4.1.52.4.1.44.4.1.3 | ColumnfilterTrapLogAcknowledged | read-only | mandatory | This field is non-zero if a trap has been acknowleged from the EM. |
| 1.3.6.1.4.1.52.4.1.44.4.1.4 | ColumnfilterTrapLogVarBind | read-only | mandatory | This is an ASN.1 encoded string representing the pairs of OID/value items supplied in the original SNMP or NVMP trap. |
| 1.3.6.1.4.1.52.4.1.44.4.1.5 | ColumnfilterTrapLogDescription | read-only | mandatory | This is an internally defined string used to describe an alarm. It's primary use is for display on the EMs LCD. A default value will be used for the old trap c… |
| 1.3.6.1.4.1.52.4.1.44.4.1.6 | ColumnfilterTimeLogged | read-only | mandatory | The time the entry was logged. This will be date and time if possible. |
| 1.3.6.1.4.1.52.4.1.44.4.1.7 | ColumnfilterFilterId | read-only | mandatory | This will be used tofilter certain alarms. The criteria is TBD. An example of classification: informational-requires no intervention. warning - Does not requir… |
| 1.3.6.1.4.1.52.4.1.44.4.1.8 | ColumnfilterSlotInChassis | read-only | mandatory | Slot of this filter entry. |
| 1.3.6.1.4.1.52.4.1.44.4.1.9 | ColumnfilterTrapOID | read-only | mandatory | This OID combines the General Trap code, Specific Trap code, and the sys object id into one OID. |
| 1.3.6.1.4.1.52.4.1.44.4.1.10 | ColumnfilterZ80Time | read-only | mandatory | The number of time ticks that have passed since this boards Z80 processor has been up. |
| 1.3.6.1.4.1.52.4.1.44.5 | ScalartrapLoggerAgent | read-write | mandatory | Reflects the operational status of the traplogger agent |