MIB Viewer

CTTRAPLOG-MIB

35 objects
No module-level DESCRIPTION found.
OIDNameAccessStatusDescription
1.3.6.1.4.1.52.4.1.44.1ScalartotalNumberOfEntriesread-onlymandatoryTotal number of logged entries for this chassis.
1.3.6.1.4.1.52.4.1.44.2TableconfigTablenot-accessiblemandatory
1.3.6.1.4.1.52.4.1.44.2.1RowconfigTableEntrynot-accessiblemandatoryEach entry allows a user to configure the alarm table for a specific slot. Objects such as Current Entry, MaxEntries Allowed, and an Enable/Disable switch are …
1.3.6.1.4.1.52.4.1.44.2.1.1ColumnslotInChassisread-onlymandatoryEach Slot can be separately configured. This is the slot number for the configuration entry.
1.3.6.1.4.1.52.4.1.44.2.1.2ColumnnumEntriesLoggedsread-onlymandatoryThis is the total number of entries looged for this slot.
1.3.6.1.4.1.52.4.1.44.2.1.3ColumnnumEntriesRequestedread-writemandatoryMaximum number of entries to store before wrapping the log on this slot.
1.3.6.1.4.1.52.4.1.44.2.1.4ColumnnumEntriesAllocatedread-onlymandatoryThis is the number of entries allocated to log alarms on this slot. It will always be less than or equal to the requested number of entries.
1.3.6.1.4.1.52.4.1.44.2.1.5ColumnlastLoggedEntryLogIdread-onlymandatoryThis is the log id of the last entry logged for this slot.
1.3.6.1.4.1.52.4.1.44.2.1.6ColumnlogCommandread-writemandatoryAllows the user to send the log the commands specified in the enumeration.
1.3.6.1.4.1.52.4.1.44.2.1.7Columnwrapread-onlymandatoryThis is whether or not this configuration has wrapped or not.
1.3.6.1.4.1.52.4.1.44.3TabletrapLogTablenot-accessiblemandatory
1.3.6.1.4.1.52.4.1.44.3.1RowtrapLogEntrynot-accessiblemandatoryEach alarm entry is generated from one of the following sources; (1) a module in one of the main chassis slots, (2) the EM, (3) or a power supply.
1.3.6.1.4.1.52.4.1.44.3.1.1ColumnlogIdread-onlymandatoryEach slot has a maximium number of log entries that it can support. Each entry is assigned a monotonically increasing sequence number. When the maximum number …
1.3.6.1.4.1.52.4.1.44.3.1.2ColumnnvmpIdread-onlymandatoryThis contains the nvmp id of the trap that occurred.
1.3.6.1.4.1.52.4.1.44.3.1.3ColumntrapLogAcknowledgedread-onlymandatoryThis field is set to 2 if a trap as been acknowledged from the EM.
1.3.6.1.4.1.52.4.1.44.3.1.4ColumntrapLogVarBindread-onlymandatoryThis is an ASN.1 encoded string representing the pairs of OID/value items supplied in the original SNMP or NVMP trap.
1.3.6.1.4.1.52.4.1.44.3.1.5ColumntrapLogDescriptionread-onlymandatoryThis is an internally defined string used to describe an alarm. Its primary use is for display on the EMs LCD. A default value will be used for the old trap ca…
1.3.6.1.4.1.52.4.1.44.3.1.6ColumntimeLoggedread-onlymandatoryThe time the entry was logged. This will be date and time if possible.
1.3.6.1.4.1.52.4.1.44.3.1.7ColumnfilterIdread-onlymandatoryThis will be used to filter certain alarms. The criteria is TBD. An example of classification: informational - requires no intervention. warning - Does not req…
1.3.6.1.4.1.52.4.1.44.3.1.8ColumnslotChassisread-onlymandatorySlot of this trap log.
1.3.6.1.4.1.52.4.1.44.3.1.9ColumntrapOIDread-onlymandatoryThis OID combines the General Trap code, Specific Trap code, and the sys object id into one OID.
1.3.6.1.4.1.52.4.1.44.3.1.10Columnz80Timeread-onlymandatoryThis is the time that the Z80 has been up for the board that sent this trap.
1.3.6.1.4.1.52.4.1.44.4TablefilterTablenot-accessiblemandatory
1.3.6.1.4.1.52.4.1.44.4.1RowfilterEntrynot-accessiblemandatoryEach filter entry is generated from one of the following sources; (1) a module in one of the main chassis slots, (2) the EM, (3) or a power supply.
1.3.6.1.4.1.52.4.1.44.4.1.1ColumnfilterLogIdread-onlymandatoryEach slot has a maximum number of log entries that it can support. Each entry is assigned a monotonically increasing sequence number. When the maximum number o…
1.3.6.1.4.1.52.4.1.44.4.1.2ColumnfilterNvmpIdread-onlymandatoryThis contains the nvmp id of the trap that was generated.
1.3.6.1.4.1.52.4.1.44.4.1.3ColumnfilterTrapLogAcknowledgedread-onlymandatoryThis field is non-zero if a trap has been acknowleged from the EM.
1.3.6.1.4.1.52.4.1.44.4.1.4ColumnfilterTrapLogVarBindread-onlymandatoryThis is an ASN.1 encoded string representing the pairs of OID/value items supplied in the original SNMP or NVMP trap.
1.3.6.1.4.1.52.4.1.44.4.1.5ColumnfilterTrapLogDescriptionread-onlymandatoryThis is an internally defined string used to describe an alarm. It's primary use is for display on the EMs LCD. A default value will be used for the old trap c…
1.3.6.1.4.1.52.4.1.44.4.1.6ColumnfilterTimeLoggedread-onlymandatoryThe time the entry was logged. This will be date and time if possible.
1.3.6.1.4.1.52.4.1.44.4.1.7ColumnfilterFilterIdread-onlymandatoryThis will be used tofilter certain alarms. The criteria is TBD. An example of classification: informational-requires no intervention. warning - Does not requir…
1.3.6.1.4.1.52.4.1.44.4.1.8ColumnfilterSlotInChassisread-onlymandatorySlot of this filter entry.
1.3.6.1.4.1.52.4.1.44.4.1.9ColumnfilterTrapOIDread-onlymandatoryThis OID combines the General Trap code, Specific Trap code, and the sys object id into one OID.
1.3.6.1.4.1.52.4.1.44.4.1.10ColumnfilterZ80Timeread-onlymandatoryThe number of time ticks that have passed since this boards Z80 processor has been up.
1.3.6.1.4.1.52.4.1.44.5ScalartrapLoggerAgentread-writemandatoryReflects the operational status of the traplogger agent