This module defines objects of the Proxy for PM
OIDNameAccessStatusDescription
1.3.6.1.4.1.2925.4.5IdentitycyPMThis module defines objects of the Proxy for PM
1.3.6.1.4.1.2925.4.5.1ScalarcyNumberOfPMread-onlycurrentThe total number of PM's connected on the unit
1.3.6.1.4.1.2925.4.5.2TablecyPMTablenot-accessiblecurrentAllows to read information about each connected PM
1.3.6.1.4.1.2925.4.5.2.1RowcyPMEntrynot-accessiblecurrentInformation about the connected PM
1.3.6.1.4.1.2925.4.5.2.1.1ColumncyPMSerialPortNumberread-onlycurrentThe number of the serial port when the PM is connected.
1.3.6.1.4.1.2925.4.5.2.1.2ColumncyPMNumberOutletsread-onlycurrentNumber of outlets.
1.3.6.1.4.1.2925.4.5.2.1.3ColumncyPMNumberUnitsread-onlycurrentTotal number of PM unists that are accessed by this serial port.
1.3.6.1.4.1.2925.4.5.2.1.4ColumncyPMCurrentread-onlycurrentCurrent reading for the PM.
1.3.6.1.4.1.2925.4.5.2.1.5ColumncyPMVersionread-onlycurrentThe software version of the PM.
1.3.6.1.4.1.2925.4.5.2.1.6ColumncyPMTemperatureread-onlycurrentThe PM temperature.
1.3.6.1.4.1.2925.4.5.2.1.7ColumncyPMCommandread-writecurrentA character string for the user to send commands to PM. He can use it to does the save command. Or to list the outlets that need to be turned off, or turned on…
1.3.6.1.4.1.2925.4.5.3TablecyPMUnitTablenot-accessiblecurrentAllow operations on specific PM unit connected
1.3.6.1.4.1.2925.4.5.3.1RowcyPMUnitEntrynot-accessiblecurrentAllow operations on outlet
1.3.6.1.4.1.2925.4.5.3.1.1ColumncyPMUnitNumbernot-accessiblecurrentThe number of the PM unit in the daisy-chained mode.
1.3.6.1.4.1.2925.4.5.3.1.2ColumncyPMUnitVersionread-onlycurrentThe software version of this PM unit.
1.3.6.1.4.1.2925.4.5.3.1.3ColumncyPMUnitOutletsread-onlycurrentNumber of outlets of this PM unit.
1.3.6.1.4.1.2925.4.5.3.1.4ColumncyPMUnitFirstOutletread-onlycurrentNumber of the first outlet of this PM unit.
1.3.6.1.4.1.2925.4.5.3.1.5ColumncyPMUnitCurrentread-onlycurrentCurrent of this PM unit in AMP. The value of this object is the actual current in AMP * 10. You need to translate the readed value (Ex. : value is 5, the curre…
1.3.6.1.4.1.2925.4.5.3.1.6ColumncyPMUnitMaxCurrentread-onlycurrentMaximum current of this PM unit in AMP. The value of this object is the maximum current in AMP * 10. You need to translate the readed value (Ex. : value is 5, …
1.3.6.1.4.1.2925.4.5.3.1.7ColumncyPMUnitTemperatureread-onlycurrentTemperature of this PM unit in Celsius degrees. The value of this object is the actual temperature in degrees C * 10. You need to translate the readed value (E…
1.3.6.1.4.1.2925.4.5.3.1.8ColumncyPMUnitMaxTemperatureread-writecurrentMaximum temperature value of this PM unit in Celsius degrees. The value of this object is the maximum temperature in degrees C * 10. You need to translate the …
1.3.6.1.4.1.2925.4.5.4TablecyOutletTablenot-accessiblecurrentAllow operations on outlet
1.3.6.1.4.1.2925.4.5.4.1RowcyOutletEntrynot-accessiblecurrentAllow operations on outlet
1.3.6.1.4.1.2925.4.5.4.1.1ColumncyOutletNumbernot-accessiblecurrentThe outlet number on the PM. Zero is ALL outlets.
1.3.6.1.4.1.2925.4.5.4.1.2ColumncyOutletNameread-writecurrentThe name given to a particular outlet Maximum size is 8 characters.
1.3.6.1.4.1.2925.4.5.4.1.3ColumncyOutletServerread-onlycurrentAlias of the Server connected to this outlet .
1.3.6.1.4.1.2925.4.5.4.1.4ColumncyOutletPowerread-writecurrentGetting this object will return the power state of the outlet. Valid return states are UNKNOW, OFF and ON. Setting this object will change the power state of t…
1.3.6.1.4.1.2925.4.5.4.1.5ColumncyOutletLockread-writecurrentGetting this object will return the lock state of the outlet. Setting this object will change the lock state of the outlet.
1.3.6.1.4.1.2925.4.5.4.1.6ColumncyOutletPUIntervalread-writecurrentThe power unit interval of this outlet in seconds. The value of this object is the actual interval in seconds * 10. You need to translate the readed value (Ex.…