MIB Viewer

Com-Server-Intern-MIB

176 objects
No module-level DESCRIPTION found.
Imported Objects
RFC-1212OBJECT-TYPE
RFC-1215TRAP-TYPE
RFC1155-SMIenterprises IpAddress NetworkAddress TimeTicks
RFC1213-MIBDisplayString PhysAddress
OIDNameAccessStatusDescription
1.3.6.1.4.1.5040Nodewut
1.3.6.1.4.1.5040.1NodewtComServer
1.3.6.1.4.1.5040.1.1NodewtComServerIntern
1.3.6.1.4.1.5040.1.1.1NodewtConfiguration
1.3.6.1.4.1.5040.1.1.1.1NodewtSystem
1.3.6.1.4.1.5040.1.1.1.1.1ScalarwtCableTyperead-onlymandatoryDisplays the Ethernet connection type used on the Com-Server.
1.3.6.1.4.1.5040.1.1.1.1.2ScalarwtMacAddressread-onlymandatoryDisplays the Ethernet address of the Com-Server.
1.3.6.1.4.1.5040.1.1.1.1.3ScalarwtSwDateread-onlymandatoryDisplays the creation date 'month/year' of the firmware.
1.3.6.1.4.1.5040.1.1.1.1.4ScalarwtSwRevread-onlymandatoryDisplays the revision number of the firmware.
1.3.6.1.4.1.5040.1.1.1.1.5ScalarwtDevTyperead-onlymandatoryDisplays the Com-Server model.
1.3.6.1.4.1.5040.1.1.1.1.6ScalarwtMibRevread-onlymandatoryDisplays the revision number of the Wiesemann & Theis MIB.
1.3.6.1.4.1.5040.1.1.1.1.7ScalarwtRunTimeread-onlymandatoryDisplays the time since the last restart of the Com-Server in 1/100 seconds.
1.3.6.1.4.1.5040.1.1.1.1.8ScalarwtPhysPortsread-onlymandatoryDisplays the total number of ports available in the Com-Server (RS232 port, digital I/O port, ...).
1.3.6.1.4.1.5040.1.1.1.1.16ScalarwtConfigModeread-writemandatoryDefining this entry allows changing (wtConfigModeOn) and saving (stSaveConfig) of all other entries in the Management Information Base of the Com-Server. If th…
1.3.6.1.4.1.5040.1.1.1.1.17ScalarwtPasswordread-writemandatory8-character Com-Server password for unrestricted access to the Com-Server configuration menu (Telnet port 1111). Only digits '0' to '9' and letters 'a' to 'f' …
1.3.6.1.4.1.5040.1.1.1.1.18ScalarwtSysPswdread-writemandatoryThe system password, which may consist of maximum 32 characters and is terminated by a zero, is of a higher order than the Telnet password and protects all the…
1.3.6.1.4.1.5040.1.1.1.1.19ScalarwtSysNameread-writemandatoryThe system name, which may consist of maximum 32 characters and is terminated by a zero, is used for identifying the Com-Server and is displayed as an opening …
1.3.6.1.4.1.5040.1.1.1.2NodewtNetSetup
1.3.6.1.4.1.5040.1.1.1.2.1ScalarwtIpAddressread-writemandatoryIP address of the Com-Server.
1.3.6.1.4.1.5040.1.1.1.2.2ScalarwtSubnetMaskread-writemandatorySubnet mask of the Com-Server.
1.3.6.1.4.1.5040.1.1.1.2.3ScalarwtGatewayread-writemandatoryIP address of the gateway for making the connections to other networks.
1.3.6.1.4.1.5040.1.1.1.2.4ScalarwtMturead-writemandatoryMaximum Transfer Unit of the Com-Server (maximum length of a datagram which the Com-Server can send or receive).
1.3.6.1.4.1.5040.1.1.1.2.5ScalarwtBootpClientread-writemandatoryActivates and deactivates sending of a BOOTP request after the Com-Server is restarted
1.3.6.1.4.1.5040.1.1.1.2.6ScalarwtKeepAliveread-writemandatoryPeriod of time without network traffic after the first Keep Alive Packet will be sent
1.3.6.1.4.1.5040.1.1.1.2.7ScalarwtRetransmTimeoutread-writemandatoryPacket retransmission timeout in ms
1.3.6.1.4.1.5040.1.1.1.2.8ScalarwtDhcpClientread-writemandatoryActivates/deactivates the DHCP client
1.3.6.1.4.1.5040.1.1.1.2.9ScalarwtWbmPortread-writemandatoryTCP port number for WebBasedManagement, 0=deactive
1.3.6.1.4.1.5040.1.1.1.2.10ScalarwtDnsSrvread-writemandatoryIP adress of DNS server.
1.3.6.1.4.1.5040.1.1.1.2.11ScalarwtLinkSpeedread-writemandatoryAutonegotiation mode = ON or fix link speed
1.3.6.1.4.1.5040.1.1.1.3NodewtSeriPortSetup
1.3.6.1.4.1.5040.1.1.1.3.1ScalarwtSerialPortsread-onlymandatoryNumber of serial ports on Com-Server
1.3.6.1.4.1.5040.1.1.1.3.2TablewtSeriInterfaceTablenot-accessiblemandatoryList of interface numbers for all serial ports.
1.3.6.1.4.1.5040.1.1.1.3.2.1RowwtSeriInterfaceEntrynot-accessiblemandatoryInterface number.
1.3.6.1.4.1.5040.1.1.1.3.2.1.1ColumnwtSeriInterfaceNoread-onlymandatoryInterface number of the serial port.
1.3.6.1.4.1.5040.1.1.1.3.3TablewtSeriUartTablenot-accessiblemandatoryList of the UART configurations relevant to the interface number of the serial port.
1.3.6.1.4.1.5040.1.1.1.3.3.1RowwtSeriUartEntrynot-accessiblemandatoryUART parameters for the serial port.
1.3.6.1.4.1.5040.1.1.1.3.3.1.1ColumnwtBaudrateread-writemandatoryBaud rate of the serial CPU port. wtBaudrate-special is read only. If wtBaudDivisor is >0 the value of wtBaudrate is 18 wtBaudrate-14400 is on available with C…
1.3.6.1.4.1.5040.1.1.1.3.3.1.2ColumnwtParityread-writemandatoryParity
1.3.6.1.4.1.5040.1.1.1.3.3.1.3ColumnwtDatabitsread-writemandatoryNumber of data bits
1.3.6.1.4.1.5040.1.1.1.3.3.1.4ColumnwtStopbitsread-writemandatoryNumber of stop bits
1.3.6.1.4.1.5040.1.1.1.3.3.1.5ColumnwtHsLinesread-writemandatoryThese two octets are interpreted bit-by-bit and describe individual values for configuring the handshake procedure. Bit 0 corresponds to the LSB. Octet Bit Nam…
1.3.6.1.4.1.5040.1.1.1.3.3.1.6ColumnwtHsFunctionsread-writemandatoryThis octet is interpreted bit-by-bit and describes functions which can be assigned to the handshake lines. Bit 0 corresponds to the LSB. Octet Bit Name Descrip…
1.3.6.1.4.1.5040.1.1.1.3.3.1.7ColumnwtUartFiforead-writemandatorySend/Receive Fifo Trigger Level of the UART port
1.3.6.1.4.1.5040.1.1.1.3.3.1.8ColumnwtUartBaudrateread-writemandatoryBaud rate of the UART port. With Com-Server 58631 and 58431 wtBaudrate istead of wtUartBaudrate must be used. wtUartBaudrate-special is read only. If wtUartBau…
1.3.6.1.4.1.5040.1.1.1.3.3.1.9ColumnwtBaudDivisorread-writemandatoryBaud Divisor of the serial p ort (special baud rate).
1.3.6.1.4.1.5040.1.1.1.3.3.1.10ColumnwtSeriInQueueread-writemandatorySerial Receive Buffer in Bytes. The value must be even. The maximum value for all models with more than one serial port and also the Office, Compact and 19' ve…
1.3.6.1.4.1.5040.1.1.1.3.4TablewtSeriPortTablenot-accessiblemandatoryList of the general port entries relevant to the interface number of the serial port.
1.3.6.1.4.1.5040.1.1.1.3.4.1RowwtSeriPortEntrynot-accessiblemandatoryPort entries for the serial port.
1.3.6.1.4.1.5040.1.1.1.3.4.1.1ColumnwtSeriLocalPortread-writemandatoryLocal TCP/UDP port number of the Com-Server port on which the Com-Server accepts a TCP connection or which it used in TCP client mode or UDP mode as a local po…
1.3.6.1.4.1.5040.1.1.1.3.4.1.2ColumnwtSeriPortModeread-writemandatoryThis parameter specifies the mode of the Com-Server port. Depending on which mode is set, the corresponding list of the relevant parameters is available. If fo…
1.3.6.1.4.1.5040.1.1.1.3.4.1.3ColumnwtSeriControlPortread-writemandatoryTCP port number of the Com-Server's control port. In TCP client or TCP server mode this port allows to change settings like baud rate, parity etc. of the seria…
1.3.6.1.4.1.5040.1.1.1.3.4.1.4ColumnwtSeriPortStateread-onlymandatoryThis value specifies the the connection state of the serial port. 0=Server mode, no connection 1=Server mode, active connection 2=Special mode, attempting to e…
1.3.6.1.4.1.5040.1.1.1.3.4.1.5ColumnwtSeriRemotePortread-onlymandatoryIf the serial port has an active TCP or UDP connection, this value shows the port number of the remote host.
1.3.6.1.4.1.5040.1.1.1.3.4.1.6ColumnwtSeriRemoteIPread-onlymandatoryIf the serial port has an active TCP or UDP connection, this value shows the IP address of the remote host.
1.3.6.1.4.1.5040.1.1.1.3.4.1.10ColumnwtSeriNetPckDelayread-writemandatoryThis value indicates the minimum wait time in 10ms ticks of the Com-Server after the arrival of serial data. After this time has expired, it packs the data int…
1.3.6.1.4.1.5040.1.1.1.3.4.1.11ColumnwtSeriFlushBufread-writemandatoryIf this switch is active (2), the serial buffer is flushed each time a new connection is opened; any residual data which could not be sent (e.g., handshake sto…
1.3.6.1.4.1.5040.1.1.1.3.4.1.12ColumnwtSeriTelnetEchoread-writemandatoryWhen opening a Telnet connection, there is negotiation on the network side to determine who generates the echo of the characters sent by the client. Either the…
1.3.6.1.4.1.5040.1.1.1.3.5TablewtSeriTcpClientTablenot-accessiblemandatoryList of all serial ports in TCP client mode relevant to their interface number.
1.3.6.1.4.1.5040.1.1.1.3.5.1RowwtSeriTcpClientEntrynot-accessiblemandatoryTCP-Client-Mode parameters
1.3.6.1.4.1.5040.1.1.1.3.5.1.1ColumnwtSeriTcpServerPortread-writemandatoryPort number which the application (TCP server process) addresses on the computer.
1.3.6.1.4.1.5040.1.1.1.3.5.1.2ColumnwtSeriTcpServerIpread-writemandatoryIP address of the computer on which the application (TCP server process) is active.
1.3.6.1.4.1.5040.1.1.1.3.5.1.3ColumnwtSeriTcpInactTimeoutread-writemandatoryConnection timeout in seconds. If no data are exchanged within the specified time, the Com-Server closes the connection to the server. The value 0 deactivates …
1.3.6.1.4.1.5040.1.1.1.3.5.1.4ColumnwtSeriTcpConnectTimeoutread-writemandatoryConnection timeout in seconds. This value is only effective in conjunction with an activated Inactivity Timeout. After the Inactivity Timeout has expired, the …
1.3.6.1.4.1.5040.1.1.1.3.5.1.5ColumnwtSeriTcpDisconnectCharread-writemandatoryIf the Com-Server receives the character set here on the serial port, the connection to the TCP server is closed. The character itself is not sent to the TCP s…
1.3.6.1.4.1.5040.1.1.1.3.5.1.6ColumnwtSeriTcpDispString1read-writemandatoryThese parameters allow compact sending of serial data to the network; the serial data stream is not broken up randomly, but rather serial packets can be sent i…
1.3.6.1.4.1.5040.1.1.1.3.5.1.7ColumnwtSeriTcpDispString2read-writemandatorySee DESCRIPTION of wtSeriTcpDispString1.
1.3.6.1.4.1.5040.1.1.1.3.5.1.8ColumnwtSeriTcpCAddressread-writemandatoryActivating this switch activates TCP client mode for changing TCP servers. The address of the TCP server does not have to be permanently configured, but rather…
1.3.6.1.4.1.5040.1.1.1.3.5.1.10ColumnwtSeriTcpResponseModeread-writemandatoryIn Response Mode the application, special characters are output which are used to inform the application in the serial terminal device about the network-side c…
1.3.6.1.4.1.5040.1.1.1.3.5.1.11ColumnwtSeriTcpServerUrlread-writemandatoryURL of the computer on which your application (TCP server process) is active. The URL can be used instead of an IP address and only in conjunction with a valid…
1.3.6.1.4.1.5040.1.1.1.3.6TablewtSeriUdpClientTablenot-accessiblemandatoryList of all serial ports in UDP mode relevant to their interface number
1.3.6.1.4.1.5040.1.1.1.3.6.1RowwtSeriUdpClientEntrynot-accessiblemandatoryUDP mode parameters
1.3.6.1.4.1.5040.1.1.1.3.6.1.1ColumnwtSeriUdpServerPortread-writemandatoryPort number which the application (UDP server process) addresses on the computer.
1.3.6.1.4.1.5040.1.1.1.3.6.1.2ColumnwtSeriUdpServerIpread-writemandatoryIP address of the computer on which the application (UDP server process) is active.
1.3.6.1.4.1.5040.1.1.1.3.6.1.3ColumnwtSeriUdpDispString1read-writemandatoryThese parameters allow compact sending of serial data to the network; the serial data stream is not broken up randomly, but rather serial packets can be sent i…
1.3.6.1.4.1.5040.1.1.1.3.6.1.4ColumnwtSeriUdpDispString2read-writemandatorySee DESCRIPTION of wtSeriUdpDispString1.
1.3.6.1.4.1.5040.1.1.1.3.6.1.5ColumnwtSeriUdpSeriProtocolread-writemandatoryThe protocol mode which can be activated here has been replaced by the 'Serial Socket Interface' (Mode: Multiport Protocol). For reasons of downward compatibil…
1.3.6.1.4.1.5040.1.1.1.3.6.1.6ColumnwtSeriUdpSeriCodingread-writemandatorySee DESCRIPTION of wtSeriUdpSeriProtocol.
1.3.6.1.4.1.5040.1.1.1.3.6.1.7ColumnwtSeriUdpCAddressread-writemandatoryActivating this option activates UDP client mode for changing UDP servers. The address of the UDP server does not have to be permanently configured, but rather…
1.3.6.1.4.1.5040.1.1.1.3.6.1.8ColumnwtSeriUdpWrCAddressread-writemandatorySet this switch to active (2) to output the address of the sender in ASCII format before sending the data of a UDP datagram to the serial port. The string alwa…
1.3.6.1.4.1.5040.1.1.1.3.6.1.9ColumnwtSeriUdpDisconnectCharread-writemandatoryThis parameter is only evaluated if the variable wtSeriUdpCAddress is activated. If the Com-Server port on the serial interface receives the character configur…
1.3.6.1.4.1.5040.1.1.1.3.6.1.10ColumnwtSeriUdpServerUrlread-writemandatoryURL of the computer on which your application (UDP process) is active. The URL can be used instead of an IP address and only in conjunction with a valid DNS se…
1.3.6.1.4.1.5040.1.1.1.3.7TablewtSeriTelnetClientTablenot-accessiblemandatoryList of all serial ports in Telnet client mode relevant to their interface number
1.3.6.1.4.1.5040.1.1.1.3.7.1RowwtSeriTelnetClientEntrynot-accessiblemandatoryTelnet client mode parameters
1.3.6.1.4.1.5040.1.1.1.3.7.1.1ColumnwtSeriTelnetServerPortread-writemandatoryPort number addressed by the Telnet server (Standard Telnet-Port: 23).
1.3.6.1.4.1.5040.1.1.1.3.7.1.2ColumnwtSeriTelnetServerIpread-writemandatoryIP address of the computer on which the Telnet server is active.
1.3.6.1.4.1.5040.1.1.1.3.7.1.3ColumnwtSeriTelnetInactTimeoutread-writemandatoryTimeout in seconds after which the Com-Server port closes the connection. The timer is reset when there is an active network connection if data are being excha…
1.3.6.1.4.1.5040.1.1.1.3.7.1.4ColumnwtSeriTelnetDisconnectCharread-writemandatoryIf the Com-Server port receives the character configured here on the serial port, the Com-Server port closes the connection to the Telnet server. It is importa…
1.3.6.1.4.1.5040.1.1.1.3.7.1.5ColumnwtSeriTelnetChangeLineoutread-writemandatoryIf this switch is activated, a 00H is appended to the serially received character 0DH: 0DH 00H is thus sent over the network. This option may need to be activa…
1.3.6.1.4.1.5040.1.1.1.3.7.1.6ColumnwtSeriTelnetServerUrlread-writemandatoryURL of the computer on which your application (Telnet server process) is active. The URL can be used instead of an IP address and only in conjunction with a va…
1.3.6.1.4.1.5040.1.1.1.3.8TablewtSeriFtpClientTablenot-accessiblemandatoryList of all serial ports in FTP client mode relevant to their interface number
1.3.6.1.4.1.5040.1.1.1.3.8.1RowwtSeriFtpClientEntrynot-accessiblemandatoryFTP client mode parameters
1.3.6.1.4.1.5040.1.1.1.3.8.1.1ColumnwtSeriFtpServerPortread-writemandatoryPort number which addresses the FTP server (Standard FTP-Port: 21).
1.3.6.1.4.1.5040.1.1.1.3.8.1.2ColumnwtSeriFtpServerIpread-writemandatoryIP address of the computer on which the FTP server is active.
1.3.6.1.4.1.5040.1.1.1.3.8.1.3ColumnwtSeriFtpAutoFtpread-writemandatorySet this switch to 2 to activate the automatic FTP client. This mode is recommended when the same command needs to be executed over and over. The FTP commands …
1.3.6.1.4.1.5040.1.1.1.3.8.1.4ColumnwtSeriFtpLoginStringread-writemandatoryCommand sequence for the FTP login in 'Automatic FTP-Client' mode. FTP client commands: TYPE A or I Activation of ASCII or binary mode STOR File Saves all seri…
1.3.6.1.4.1.5040.1.1.1.3.8.1.5ColumnwtSeriFtpInactTimeoutread-writemandatoryConfigure the commands STOR and APPE(nd) with a timeout in seconds for closing the connection. If during this time no serial data are received, the FTP client …
1.3.6.1.4.1.5040.1.1.1.3.8.1.6ColumnwtSeriFtpConnectTimeoutread-writemandatoryConnection timeout in seconds. This value is only effective in conjunction with an activated Inactivity Timeout. After the Inactivity Timeout has expired, the …
1.3.6.1.4.1.5040.1.1.1.3.8.1.7ColumnwtSeriFtpProtocolCharread-writemandatoryWhen the Com-Server receives the character configured here on its serial port, the Com-Server port closes the connection to the FTP server. This is also used a…
1.3.6.1.4.1.5040.1.1.1.3.8.1.8ColumnwtSeriFtpServerUrlread-writemandatoryURL of the computer on which your application (FTP server process) is active. The URL can be used instead of an IP address and only in conjunction with a valid…
1.3.6.1.4.1.5040.1.1.1.3.9TablewtSeriMultiPortPrtTablenot-accessiblemandatoryList of all serial ports in multiport protocol mode relevant to their interface number
1.3.6.1.4.1.5040.1.1.1.3.9.1RowwtSeriMultiPortPrtEntrynot-accessiblemandatoryMultiport-Protocol-Mode parameters
1.3.6.1.4.1.5040.1.1.1.3.9.1.1ColumnwtSeriPrtSeriProtocolread-writemandatoryThis switch activates/deactivates the Serial Socket Interface. Detailed protocol documentation is available on our Web site (http://www.wut.de) for downloading.
1.3.6.1.4.1.5040.1.1.1.3.9.1.2ColumnwtSeriPrtSeriCodingread-writemandatoryThis switch activated character doubling. It ensures reliable packet frame detection when transmitting binary data, without having to exclude certain character…
1.3.6.1.4.1.5040.1.1.1.3.9.1.3ColumnwtSeriPrtProtocolCharread-writemandatoryIf character doubling is not used, configure here a packet frame character. This character is not allowed to be used in the data stream.
1.3.6.1.4.1.5040.1.1.1.3.10TablewtSeriB2bMasterTablenot-accessiblemandatoryList of all serial ports in Box-to-Box Master Mode relevant to their interface number.
1.3.6.1.4.1.5040.1.1.1.3.10.1RowwtSeriB2bMasterEntrynot-accessiblemandatoryBox-to-Box-Master-Mode parameters.
1.3.6.1.4.1.5040.1.1.1.3.10.1.1ColumnwtSeriB2bMaster-SlavePortread-writemandatoryPort number of the serial Com-Server-Slave port.
1.3.6.1.4.1.5040.1.1.1.3.10.1.2ColumnwtSeriB2bMaster-SlaveIpread-writemandatoryIP address of the Com-Server in which the slave port is located.
1.3.6.1.4.1.5040.1.1.1.3.10.1.3ColumnwtSeriB2bMaster-DispString1read-writemandatoryThis mode allows compact sending of serial data to the network; the serial data stream is not broken up randomly, but rather serial packets can be sent in thei…
1.3.6.1.4.1.5040.1.1.1.3.10.1.4ColumnwtSeriB2bMaster-DispString2read-writemandatorySee DESCRIPTION for wtSeriB2bMaster-DispString1.
1.3.6.1.4.1.5040.1.1.1.3.11TablewtSeriB2bSlaveTablenot-accessiblemandatoryList of all serial ports in Box-to-Box-Slave-Mode relevant to their interface number
1.3.6.1.4.1.5040.1.1.1.3.11.1RowwtSeriB2bSlaveEntrynot-accessiblemandatoryBox-to-Box-Slave-Mode parameters.
1.3.6.1.4.1.5040.1.1.1.3.11.1.1ColumnwtSeriB2bSlave-MasterPortread-onlymandatoryPort number of the serial Com-Server Master port.
1.3.6.1.4.1.5040.1.1.1.3.11.1.2ColumnwtSeriB2bSlave-MasterIpread-onlymandatoryIP address of the Com-Server in which the Master port is located.
1.3.6.1.4.1.5040.1.1.1.3.11.1.3ColumnwtSeriB2bSlave-DispString1read-writemandatoryThis mode allow compact sending of serial data to the network; the serial data stream is not broken up randomly, but rather serial packets can be sent in their…
1.3.6.1.4.1.5040.1.1.1.3.11.1.4ColumnwtSeriB2bSlave-DispString2read-writemandatorySee DESCRIPTION of wtSeriB2bSlave-DispString1.
1.3.6.1.4.1.5040.1.1.1.3.12TablewtSeriIpBusTablenot-accessiblemandatoryList of all serial ports in IP-Bus-Mode relevant to their interface number
1.3.6.1.4.1.5040.1.1.1.3.12.1RowwtSeriIpBusEntrynot-accessiblemandatoryIP-Bus-Mode parameters.
1.3.6.1.4.1.5040.1.1.1.3.12.1.1ColumnwtSeriBusSlave-MasterIpread-writemandatorySetting on Com-Server ports connected to Slaves: Set here the complete IP address of the Com-Server with the Master port.
1.3.6.1.4.1.5040.1.1.1.3.12.1.2ColumnwtSeriBusMaster-SubnetIpread-writemandatorySetting on a Com-Server port connected to the Master: Enter here the network address of the Subnet in which the Master and Slaves are located. It is sufficient…
1.3.6.1.4.1.5040.1.1.1.3.13TablewtSeriSlipTablenot-accessiblemandatoryList of all ports in SLIP-Mode relevant to their interface number
1.3.6.1.4.1.5040.1.1.1.3.13.1RowwtSeriSlipEntrynot-accessiblemandatorySLIP-Mode parameters.
1.3.6.1.4.1.5040.1.1.1.3.13.1.1ColumnwtSeriSlipNetAddressread-writemandatoryEnter here the network address of the serially connected Subnet to which you want to route using SLIP.
1.3.6.1.4.1.5040.1.1.1.3.13.1.2ColumnwtSeriSlipNetRoutingread-writemandatoryIf this parameter has a value of 2, the Com-Server operates as a router for the Subnet specified under wtSeriSlipNetAddress. If the parameter has a value of 1,…
1.3.6.1.4.1.5040.1.1.1.4NodewtDeaPortSetup
1.3.6.1.4.1.5040.1.1.1.4.1ScalarwtDeaPortsread-onlymandatoryNumber of Com-Server digital I/O ports
1.3.6.1.4.1.5040.1.1.1.4.2TablewtDeaInterfaceTablenot-accessiblemandatoryList of interface numbers of all digital I/O ports.
1.3.6.1.4.1.5040.1.1.1.4.2.1RowwtDeaInterfaceEntrynot-accessiblemandatoryInterface number
1.3.6.1.4.1.5040.1.1.1.4.2.1.1ColumnwtDeaInterfaceNoread-onlymandatoryInterface number of the digital I/O ports.
1.3.6.1.4.1.5040.1.1.1.4.3TablewtDeaPortTablenot-accessiblemandatoryList of the general port entries relevant to the interface number of the digital I/O ports.
1.3.6.1.4.1.5040.1.1.1.4.3.1RowwtDeaPortEntrynot-accessiblemandatoryPort entries of the digital I/O ports.
1.3.6.1.4.1.5040.1.1.1.4.3.1.1ColumnwtDeaLocalPortread-writemandatoryLocal TCP/UDP port number of the Com-Server port. Port number on which the Com-Server accepts a TCP connection or which it uses as a local port in TCP client m…
1.3.6.1.4.1.5040.1.1.1.4.3.1.2ColumnwtDeaPortModeread-writemandatoryThis parameter specifies the mode for the Com-Server port. Depending on which mode is set, the corresponding list of the relevant parameters is available. If f…
1.3.6.1.4.1.5040.1.1.1.4.3.1.3ColumnwtDeaDrvWatchdogread-writemandatoryThis parameter allows control of all instances which are active between the card driver in the Com-Server and the application on the computer, including the co…
1.3.6.1.4.1.5040.1.1.1.4.4TablewtDeaTcpClientTablenot-accessiblemandatoryList of all digital I/O ports in TCP-Client-Mode relevant to their interface number
1.3.6.1.4.1.5040.1.1.1.4.4.1RowwtDeaTcpClientEntrynot-accessiblemandatoryTCP-Client-Mode parameters
1.3.6.1.4.1.5040.1.1.1.4.4.1.1ColumnwtDeaTcpServerPortread-writemandatoryPort number which the application (TCP server process) addresses on the computer.
1.3.6.1.4.1.5040.1.1.1.4.4.1.2ColumnwtDeaTcpServerIpread-writemandatoryIP address of the computer on which the application (TCP server process) is active.
1.3.6.1.4.1.5040.1.1.1.4.4.1.3ColumnwtDeaTcpInactTimeoutread-writemandatoryConnection timeout in seconds. If no data are exchanged within the specified time, the Com-Server closes the connection to the TCP server. The value 0 deactiva…
1.3.6.1.4.1.5040.1.1.1.4.4.1.4ColumnwtDeaTcpConnectTimeoutread-writemandatoryConnection timeout in seconds. This value is only effective in conjunction with an activated inactivity timeout. After the inactivity timeout has expired, the …
1.3.6.1.4.1.5040.1.1.1.4.4.1.5ColumnwtDeaTcpInputMaskread-writemandatoryHere the inputs to be polled by the card driver are configured. When a level change occurs on one or more inputs, the TCP connection to the application (TCP se…
1.3.6.1.4.1.5040.1.1.1.4.5TablewtDeaUdpClientTablenot-accessiblemandatoryList of all digital I/O ports in UDP-Mode relevant to their interface number
1.3.6.1.4.1.5040.1.1.1.4.5.1RowwtDeaUdpClientEntrynot-accessiblemandatoryUDP-Mode parameters
1.3.6.1.4.1.5040.1.1.1.4.5.1.1ColumnwtDeaUdpServerPortread-writemandatoryPort number which the application (UPD server process) on the computer addresses.
1.3.6.1.4.1.5040.1.1.1.4.5.1.2ColumnwtDeaUdpServerIpread-writemandatoryIP address of the computer on which the application (UDP server process) is active.
1.3.6.1.4.1.5040.1.1.1.4.5.1.3ColumnwtDeaUdpPacketProtocolread-writemandatoryThis switch activates (2) or deactivates (1) of the control procedure for the packet sequence in UDP mode (see also manual for I/O Com-Server.
1.3.6.1.4.1.5040.1.1.1.4.5.1.4ColumnwtDeaUdpInputMaskread-writemandatoryHere the inputs to be polled by the card driver are configured. When a level change occurs on one or more inputs, the TCP connection to the application (TCP se…
1.3.6.1.4.1.5040.1.1.1.4.5.1.5ColumnwtDeaUdpSendIntervalread-writemandatoryConfigurable interval with a 100ms base, in which the card driver sends the I/O structure 'Write Register' with the contents of the input register to the confi…
1.3.6.1.4.1.5040.1.1.1.4.6TablewtDeaSnmpAgentTablenot-accessiblemandatoryList of all digital I/O ports in Snmp-Agent-Mode relevant to their interface number
1.3.6.1.4.1.5040.1.1.1.4.6.1RowwtDeaSnmpAgentEntrynot-accessiblemandatorySnmp-Agent-Mode parameters
1.3.6.1.4.1.5040.1.1.1.4.6.1.1ColumnwtDeaSnmpManagerIpread-writemandatoryIP address of the computer on which the SNMP Manager is located to which the Com-Server should send SNMP traps.
1.3.6.1.4.1.5040.1.1.1.4.6.1.2ColumnwtDeaSnmpInputMaskread-writemandatoryHere the inputs to be polled by the card driver are configured. When a level change occurs on one or more inputs, an SNMP trap with the variable dDrvInputRegis…
1.3.6.1.4.1.5040.1.1.1.4.6.1.3ColumnwtDeaSnmpSendIntervalread-writemandatoryConfigurable interval with a 100ms base, in which the card driver reads the input register and sends an SNMP trap with the variable dDrvInputRegister (see TRAP…
1.3.6.1.4.1.5040.1.1.1.4.7TablewtDeaB2bMasterTablenot-accessiblemandatoryList of all digital I/O ports in Box-to-Box-Master-Mode relevant to their interface number
1.3.6.1.4.1.5040.1.1.1.4.7.1RowwtDeaB2bMasterEntrynot-accessiblemandatoryBox-to-Box-Master-Mode parameters
1.3.6.1.4.1.5040.1.1.1.4.7.1.1ColumnwtDeaB2bMaster-SlavePortread-writemandatoryPort number of the digital I/O Com-Server-Slave port.
1.3.6.1.4.1.5040.1.1.1.4.7.1.2ColumnwtDeaB2bMaster-SlaveIpread-writemandatoryIP address of the I/O Com-Server in which the Slave port is located.
1.3.6.1.4.1.5040.1.1.1.4.7.1.3ColumnwtDeaB2bMaster-InputMaskread-writemandatoryHere the inputs to be polled by the card drive are configured. When a level change occurs on one or more inputs, the entire input register is sent over the net…
1.3.6.1.4.1.5040.1.1.1.4.7.1.4ColumnwtDeaB2bMaster-SendIntervalread-writemandatoryConfigurable interval with a 100ms base, in which the card driver maps the input register to the output register of the other I/O port. A value of 0 deactivate…
1.3.6.1.4.1.5040.1.1.1.4.8TablewtDeaB2bSlaveTablenot-accessiblemandatoryList of all digital I/O ports in Box-to-Box-Slave-Mode relevant to their interface number
1.3.6.1.4.1.5040.1.1.1.4.8.1RowwtDeaB2bSlaveEntrynot-accessiblemandatoryBox-to-Box-Slave-Mode parameters
1.3.6.1.4.1.5040.1.1.1.4.8.1.1ColumnwtDeaB2bSlave-MasterPortread-onlymandatoryPort number of the digital I/O Com-Server-Master port.
1.3.6.1.4.1.5040.1.1.1.4.8.1.2ColumnwtDeaB2bSlave-MasterIpread-onlymandatoryIP address of the I/O Com-Server in which the Master port is located.
1.3.6.1.4.1.5040.1.1.1.4.8.1.3ColumnwtDeaB2bSlave-InputMaskread-writemandatoryHere the inputs to be polled by the card driver are configured. When a level change occurs on one or more inputs, the entire input register is sent over the ne…
1.3.6.1.4.1.5040.1.1.1.4.8.1.4ColumnwtDeaB2bSlave-SendIntervalread-writemandatoryConfigurable interval with a 100ms base, in which the card driver maps the input register to the output register of the other I/O port. The value 0 deactivates…
1.3.6.1.4.1.5040.1.1.2NodewtDeaDriver
1.3.6.1.4.1.5040.1.1.2.1TablewtDeaDrvTablenot-accessiblemandatoryList of all functions for managing the digital I/O port relevant to their interface number.
1.3.6.1.4.1.5040.1.1.2.1.1RowwtDeaDrvEntrynot-accessiblemandatoryFunctions for managing a digital I/O port.
1.3.6.1.4.1.5040.1.1.2.1.1.1NodedeaInputChangedAlertThis SNMP trap is generated when the level of an input on the digital I/O port has changed.
1.3.6.1.4.1.5040.1.1.2.1.1.1ColumnwtDeaDrvInterfaceNoread-onlymandatoryInterface number of the digital I/O port.
1.3.6.1.4.1.5040.1.1.2.1.1.2NodedeaIntervalExpiredAlertThis SNMP trap is generated in the interval configured in the variable wtDeaDrvTrapInterval or variable wtDeaSnmpSendInterval.
1.3.6.1.4.1.5040.1.1.2.1.1.2ColumnwtDeaDrvInputRegisterread-onlymandatoryThis variable is used to read the outputs of the digital I/O port. The OCTETS are interpreted bit-by-bit, with each bit corresponding to an output. Bit 0 corre…
1.3.6.1.4.1.5040.1.1.2.1.1.3ColumnwtDeaDrvOutputRegisterread-writemandatoryThis variable is used to read and write the outputs of the digital I/O port. The OCTETS are interpreted bit-by-bit, with each bit corresponding to an output. B…
1.3.6.1.4.1.5040.1.1.2.1.1.4ColumnwtDeaDrvSetBitread-writemandatoryThis variable allows setting of individual digital outputs. The OCTETS are interpreted bit-by-bit, with each bit corresponding to an output. Bit 0 corresponds …
1.3.6.1.4.1.5040.1.1.2.1.1.5ColumnwtDeaDrvTrapInputMaskread-writemandatoryHere the inputs to be polled by the card driver are configured. When a level change occurs on one or more inputs, an SNMP trap is sent to the configured SNMP M…
1.3.6.1.4.1.5040.1.1.2.1.1.6ColumnwtDeaDrvTrapIntervalread-writemandatoryConfigurable variable with a 100ms basis, in which the card driver reads the input register and sends an SNMP trap to the configured SNMP Manager with the vari…