DELL-MM-MIB

171 objects
No module-level DESCRIPTION found.
Imported Objects
RFC-1212OBJECT-TYPE
RFC-1215TRAP-TYPE
RFC1155-SMIenterprises TimeTicks
RFC1213-MIBDisplayString
OIDNameAccessStatusDescription
1.3.6.1.4.1.674Nodedell
1.3.6.1.4.1.674.10892Nodeserver3
1.3.6.1.4.1.674.10892.6NodedmmOutOfBandGroup
1.3.6.1.4.1.674.10892.6.1NodedmmInformationGroup
1.3.6.1.4.1.674.10892.6.1.1NodedmmProductInfoGroup
1.3.6.1.4.1.674.10892.6.1.1.1ScalardmmProductNameread-onlymandatoryThis attribute defines the product name of a chassis management module.
1.3.6.1.4.1.674.10892.6.1.1.2ScalardmmProductShortNameread-onlymandatoryThis attribute defines the short product name of a chassis management module.
1.3.6.1.4.1.674.10892.6.1.1.3ScalardmmProductDescriptionread-onlymandatoryThis attribute defines the product description of a chassis management module.
1.3.6.1.4.1.674.10892.6.1.1.4ScalardmmProductManufacturerread-onlymandatoryThis attribute defines the product manufacturer of a chassis management module.
1.3.6.1.4.1.674.10892.6.1.1.5ScalardmmProductVersionread-onlymandatoryThis attribute defines the product version of a chassis management module.
1.3.6.1.4.1.674.10892.6.1.1.6ScalardmmChassisServiceTagread-onlymandatoryThis attribute defines the Service Tag of the chassis.
1.3.6.1.4.1.674.10892.6.1.1.7ScalardmmProductURLread-onlymandatoryThis attribute defines the out-of-band UI URL of a chassis management module.
1.3.6.1.4.1.674.10892.6.1.1.8ScalardmmProductChassisAssetTagread-onlymandatoryThis attribute defines the Asset Tag of the chassis.
1.3.6.1.4.1.674.10892.6.1.1.9ScalardmmProductChassisNameread-onlymandatoryThis attribute defines the name of the chassis.
1.3.6.1.4.1.674.10892.6.1.1.10ScalardmmProductTyperead-onlymandatoryThis attribute defines type of a remote management module
1.3.6.1.4.1.674.10892.6.1.1.11ScalardmmProductChassisDataCenterread-onlymandatoryThis attribute defines the Data Center locator of the chassis.
1.3.6.1.4.1.674.10892.6.1.1.12ScalardmmProductChassisAisleread-onlymandatoryThis attribute defines the Aisle locator of the chassis.
1.3.6.1.4.1.674.10892.6.1.1.13ScalardmmProductChassisRackread-onlymandatoryThis attribute defines the Rack locator of the chassis.
1.3.6.1.4.1.674.10892.6.1.1.14ScalardmmProductChassisRackSlotread-onlymandatoryThis attribute defines the Rack Slot locator of the chassis.
1.3.6.1.4.1.674.10892.6.1.1.15ScalardmmProductChassisModelread-onlymandatoryThis attribute defines the Model of the chassis.
1.3.6.1.4.1.674.10892.6.1.1.16ScalardmmProductChassisExpressServiceCoderead-onlymandatoryThis attribute defines the Express Service Code of the chassis.
1.3.6.1.4.1.674.10892.6.1.1.17ScalardmmProductChassisSystemIDread-onlymandatoryThis attribute defines the System ID of the chassis.
1.3.6.1.4.1.674.10892.6.1.2NodedmmFirmwareGroup
1.3.6.1.4.1.674.10892.6.1.2.1ScalardmmFirmwareVersionread-onlymandatoryThis attribute defines the firmware version of chassis management module 1.
1.3.6.1.4.1.674.10892.6.1.2.2ScalardmmFirmwareVersion2read-onlymandatoryThis attribute defines the firmware version of chassis management module 2.
1.3.6.1.4.1.674.10892.6.2NodedmmStatusGroup
1.3.6.1.4.1.674.10892.6.2.1ScalardmmGlobalSystemStatusread-onlymandatoryThis attribute defines the overall chassis status being monitored by the chassis management module.
1.3.6.1.4.1.674.10892.6.3NodedmmChassisStatusGroup
1.3.6.1.4.1.674.10892.6.3.1NodedmmStatusNowGroup
1.3.6.1.4.1.674.10892.6.3.1.1ScalardmmIOMCurrStatusread-onlymandatoryThis attribute defines the IOM subsystem status being monitored by the chassis management module.
1.3.6.1.4.1.674.10892.6.3.1.2ScalardmmRedCurrStatusread-onlymandatoryThis attribute defines the Redundancy status being monitored by the chassis management module.
1.3.6.1.4.1.674.10892.6.3.1.3ScalardmmPowerCurrStatusread-onlymandatoryThis attribute defines the power subsystem health status being monitored by the chassis management module.
1.3.6.1.4.1.674.10892.6.3.1.4ScalardmmFanCurrStatusread-onlymandatoryThis attribute defines the Fan subsystem health status being monitored by the chassis management module.
1.3.6.1.4.1.674.10892.6.3.1.5ScalardmmBladeCurrStatusread-onlymandatoryThis attribute defines the Blade subsystem health status being monitored by the chassis management module.
1.3.6.1.4.1.674.10892.6.3.1.6ScalardmmTempCurrStatusread-onlymandatoryThis attribute defines the Temp Sensor subsystem health status being monitored by the chassis management module.
1.3.6.1.4.1.674.10892.6.3.1.7ScalardmmMMCurrStatusread-onlymandatoryThis attribute defines the health status being monitored by the chassis management module.
1.3.6.1.4.1.674.10892.6.3.1.8ScalardmmChassisFrontPanelAmbientTemperatureread-onlymandatoryThis attribute defines the ambient temperature reading (in degrees Celsius) for the chassis front panel module.
1.3.6.1.4.1.674.10892.6.4NodedmmChassisPowerGroup
1.3.6.1.4.1.674.10892.6.4.1TabledmmPowerTablenot-accessiblemandatoryThis object defines the power table.
1.3.6.1.4.1.674.10892.6.4.1.1RowdmmPowerTableEntrynot-accessiblemandatoryThis object defines the power table entry.
1.3.6.1.4.1.674.10892.6.4.1.1.1ColumndmmPowerChassisIndexread-onlymandatoryThis attribute defines the index (one-based) of the associated chassis.
1.3.6.1.4.1.674.10892.6.4.1.1.2ColumndmmPowerIdlePowerread-onlymandatoryThis attribute defines the power (in Watts) required by the chassis infrastructure, plus the sum of the minimum power requirements for all currently powered-on…
1.3.6.1.4.1.674.10892.6.4.1.1.3ColumndmmPowerKWhCumulativeread-onlymandatoryThis attribute defines the cumulative chassis power usage (in KWh) since last reset.
1.3.6.1.4.1.674.10892.6.4.1.1.4ColumndmmPowerKWhCumulativeTimeread-onlymandatoryThis attribute defines the timestamp of the most recent chassis power accumulator reset.
1.3.6.1.4.1.674.10892.6.4.1.1.5ColumndmmPowerWattsPeakUsageread-onlymandatoryThis attribute defines the chassis peak power usage (in Watts) since last reset.
1.3.6.1.4.1.674.10892.6.4.1.1.6ColumndmmPowerWattsPeakTimeread-onlymandatoryThis attribute defines the timestamp of the most recent chassis peak power usage.
1.3.6.1.4.1.674.10892.6.4.1.1.7ColumndmmPowerWattsMinUsageread-onlymandatoryThis attribute defines the chassis mimimum power usage (in Watts) since last reset.
1.3.6.1.4.1.674.10892.6.4.1.1.8ColumndmmPowerWattsMinTimeread-onlymandatoryThis attribute defines the timestamp of the most recent chassis minimum power usage.
1.3.6.1.4.1.674.10892.6.4.1.1.9ColumndmmPowerWattsReadingread-onlymandatoryThis attribute defines the instantaneous chassis power usage (in Watts).
1.3.6.1.4.1.674.10892.6.4.2TabledmmPSUTablenot-accessiblemandatoryThis object defines the PSU table.
1.3.6.1.4.1.674.10892.6.4.2.1RowdmmPSUTableEntrynot-accessiblemandatoryThis object defines the PSU table entry.
1.3.6.1.4.1.674.10892.6.4.2.1.1ColumndmmPSUChassisIndexread-onlymandatoryThis attribute defines the index (one-based) of the associated chassis.
1.3.6.1.4.1.674.10892.6.4.2.1.2ColumndmmPSUIndexread-onlymandatoryThis attribute defines the index (one-based) of the associated PSU.
1.3.6.1.4.1.674.10892.6.4.2.1.3ColumndmmPSULocationread-onlymandatoryThis attribute defines the location of the PSU.
1.3.6.1.4.1.674.10892.6.4.2.1.4ColumndmmPSUStateread-onlymandatoryThis attribute defines the enabled state of of the PSU.
1.3.6.1.4.1.674.10892.6.4.2.1.5ColumndmmPSUTyperead-onlymandatoryThis attribute defines the type of the PSU.
1.3.6.1.4.1.674.10892.6.4.2.1.6ColumndmmPSUCapacityread-onlymandatoryThis attribute defines the capacity in watts of the PSU.
1.3.6.1.4.1.674.10892.6.4.2.1.7ColumndmmPSUVoltageread-onlymandatoryThis attribute defines the input voltage of the PSU.
1.3.6.1.4.1.674.10892.6.4.2.1.8ColumndmmPSUCurrStatusread-onlymandatoryThis attribute defines the current status of the PSU.
1.3.6.1.4.1.674.10892.6.5NodedmmChassisAlert2Group
1.3.6.1.4.1.674.10892.6.5.1NodedmmChassisAlert2Variables
1.3.6.1.4.1.674.10892.6.5.1.1ScalardmmCA2MessageIDread-onlymandatoryMessage ID of the alert.
1.3.6.1.4.1.674.10892.6.5.1.2ScalardmmCA2Messageread-onlymandatoryMessage describing the alert.
1.3.6.1.4.1.674.10892.6.5.1.3ScalardmmCA2MessageArgsread-onlymandatoryConcatenated set of strings representing any message arguments that were used to construct the alert message. Each message argument string is enclosed in doubl…
1.3.6.1.4.1.674.10892.6.5.1.4ScalardmmCA2AlertStatusread-onlymandatoryStatus of the alert.
1.3.6.1.4.1.674.10892.6.5.1.5ScalardmmCA2FQDDread-onlymandatoryFully qualified device descriptor of device causing the alert.
1.3.6.1.4.1.674.10892.6.5.2153Nodealert2FanFailureFan failure.
1.3.6.1.4.1.674.10892.6.5.2154Nodealert2FanWarningFan warning.
1.3.6.1.4.1.674.10892.6.5.2155Nodealert2FanInformationFan information.
1.3.6.1.4.1.674.10892.6.5.2161Nodealert2TemperatureProbeFailureTemperature sensor has detected a failure value.
1.3.6.1.4.1.674.10892.6.5.2162Nodealert2TemperatureProbeWarningTemperature sensor has detected a warning value.
1.3.6.1.4.1.674.10892.6.5.2163Nodealert2TemperatureProbeNormalTemperature sensor value is within range.
1.3.6.1.4.1.674.10892.6.5.2169Nodealert2VoltageProbeFailureVoltage sensor has detected a failure value.
1.3.6.1.4.1.674.10892.6.5.2170Nodealert2VoltageProbeWarningVoltage sensor has detected a warning value.
1.3.6.1.4.1.674.10892.6.5.2171Nodealert2VoltageProbeNormalVoltage sensor reading is within range.
1.3.6.1.4.1.674.10892.6.5.2177Nodealert2AmperageProbeFailureCurrent sensor has detected a failure value.
1.3.6.1.4.1.674.10892.6.5.2178Nodealert2AmperageProbeWarningCurrent sensor has detected a warning value.
1.3.6.1.4.1.674.10892.6.5.2179Nodealert2AmperageProbeNormalCurrent sensor reading is within range.
1.3.6.1.4.1.674.10892.6.5.2185Nodealert2PowerSupplyFailurePower supply has detected a failure.
1.3.6.1.4.1.674.10892.6.5.2186Nodealert2PowerSupplyWarningPower supply has detected a warning.
1.3.6.1.4.1.674.10892.6.5.2187Nodealert2PowerSupplyNormalPower supply has returned to normal.
1.3.6.1.4.1.674.10892.6.5.2225Nodealert2BatteryFailureBattery has failed or battery is absent.
1.3.6.1.4.1.674.10892.6.5.2226Nodealert2BatteryWarningBattery is low.
1.3.6.1.4.1.674.10892.6.5.2227Nodealert2BatteryNormalBattery state has returned to normal; or battery presence had been detected.
1.3.6.1.4.1.674.10892.6.5.2249Nodealert2LinkStatusFailureLink status failure or critical event.
1.3.6.1.4.1.674.10892.6.5.2250Nodealert2LinkStatusWarningLink status warning.
1.3.6.1.4.1.674.10892.6.5.2251Nodealert2LinkStatusInformationLink status information.
1.3.6.1.4.1.674.10892.6.5.2273Nodealert2PowerUsageFailurePower usage failure.
1.3.6.1.4.1.674.10892.6.5.2274Nodealert2PowerUsageWarningPower usage warning.
1.3.6.1.4.1.674.10892.6.5.2275Nodealert2PowerUsageInformationPower usage information.
1.3.6.1.4.1.674.10892.6.5.2329Nodealert2HardwareConfigurationFailureHardware configuration failure or critical event.
1.3.6.1.4.1.674.10892.6.5.2330Nodealert2HardwareConfigurationWarningHardware configuration warning.
1.3.6.1.4.1.674.10892.6.5.2331Nodealert2HardwareConfigurationInformationHardware configuration information.
1.3.6.1.4.1.674.10892.6.5.2337Nodealert2SoftwareConfigurationFailureSoftware configuration failure.
1.3.6.1.4.1.674.10892.6.5.2338Nodealert2SoftwareConfigurationWarningSoftware configuration warning.
1.3.6.1.4.1.674.10892.6.5.2339Nodealert2SoftwareConfigurationInformationSoftware configuration information.
1.3.6.1.4.1.674.10892.6.5.2377Nodealert2SystemEventLogFailureSystem Event Log failure or critical event.
1.3.6.1.4.1.674.10892.6.5.2378Nodealert2SystemEventLogWarningSystem Event Log warning.
1.3.6.1.4.1.674.10892.6.5.2379Nodealert2SystemEventLogInformationSystem Event Log information.
1.3.6.1.4.1.674.10892.6.5.2385Nodealert2SecurityFailureSecurity failure or critical event.
1.3.6.1.4.1.674.10892.6.5.2386Nodealert2SecurityWarningSecurity warning.
1.3.6.1.4.1.674.10892.6.5.2387Nodealert2SecurityInformationSecurity information.
1.3.6.1.4.1.674.10892.6.5.2393Nodealert2CableFailureCable failure.
1.3.6.1.4.1.674.10892.6.5.2465Nodealert2PowerSupplyAbsentPower supply is absent.
1.3.6.1.4.1.674.10892.6.5.2473Nodealert2RedundancyLostRedundancy is lost.
1.3.6.1.4.1.674.10892.6.5.2474Nodealert2RedundancyDegradedRedundancy is degraded.
1.3.6.1.4.1.674.10892.6.5.2475Nodealert2RedundancyInformationRedundancy information.
1.3.6.1.4.1.674.10892.6.5.2545Nodealert2CMCFailureChassis Management Module detected an error.
1.3.6.1.4.1.674.10892.6.5.2546Nodealert2CMCWarningChassis Management Module detected a warning.
1.3.6.1.4.1.674.10892.6.5.2553Nodealert2IOVirtualizationFailureIO Virtualization failure or critical event.
1.3.6.1.4.1.674.10892.6.5.2554Nodealert2IOVirtualizationWarningIO Virtualization warning.
1.3.6.1.4.1.674.10892.6.5.2555Nodealert2IOVirtualizationInformationIO Virtualization information.
1.3.6.1.4.1.674.10892.6.5.4177Nodealert2StorageManagementFailureStorage Management has detected a device independent error condition. There is no global status change associated with this trap.
1.3.6.1.4.1.674.10892.6.5.4178Nodealert2StorageManagementWarningStorage Management has detected a device independent warning condition. There is no global status change associated with this trap.
1.3.6.1.4.1.674.10892.6.5.4179Nodealert2StorageManagementInformationStorage Management information. There is no global status change associated with this trap.
1.3.6.1.4.1.674.10892.6.5.4201Nodealert2StorageFanFailureStorage Fan failure.
1.3.6.1.4.1.674.10892.6.5.4202Nodealert2StorageFanWarningStorage Fan warning.
1.3.6.1.4.1.674.10892.6.5.4203Nodealert2StorageFanInformationStorage Fan information.
1.3.6.1.4.1.674.10892.6.5.4209Nodealert2StorageTemperatureProbeFailureStorage Temperature probe failure.
1.3.6.1.4.1.674.10892.6.5.4210Nodealert2StorageTemperatureProbeWarningStorage Temperature probe warning.
1.3.6.1.4.1.674.10892.6.5.4211Nodealert2StorageTemperatureProbeInformationStorage Temperature probe information.
1.3.6.1.4.1.674.10892.6.5.4233Nodealert2StoragePowerSupplyFailureStorage Power supply failure.
1.3.6.1.4.1.674.10892.6.5.4234Nodealert2StoragePowerSupplyWarningStorage Power supply warning.
1.3.6.1.4.1.674.10892.6.5.4235Nodealert2StoragePowerSupplyInformationStorage Power supply information.
1.3.6.1.4.1.674.10892.6.5.4273Nodealert2StorageBatteryFailureStorage Battery failure.
1.3.6.1.4.1.674.10892.6.5.4274Nodealert2StorageBatteryWarningStorage Battery warning.
1.3.6.1.4.1.674.10892.6.5.4275Nodealert2StorageBatteryInformationStorage Battery information.
1.3.6.1.4.1.674.10892.6.5.4329Nodealert2StorageControllerFailureStorage Controller failure.
1.3.6.1.4.1.674.10892.6.5.4330Nodealert2StorageControllerWarningStorage Controller warning.
1.3.6.1.4.1.674.10892.6.5.4331Nodealert2StorageControllerInformationStorage Controller information.
1.3.6.1.4.1.674.10892.6.5.4337Nodealert2StorageEnclosureFailureStorage Enclosure failure.
1.3.6.1.4.1.674.10892.6.5.4338Nodealert2StorageEnclosureWarningStorage Enclosure warning.
1.3.6.1.4.1.674.10892.6.5.4339Nodealert2StorageEnclosureInformationStorage Enclosure information.
1.3.6.1.4.1.674.10892.6.5.4345Nodealert2StoragePhysicalDiskFailureStorage Physical disk failure.
1.3.6.1.4.1.674.10892.6.5.4346Nodealert2StoragePhysicalDiskWarningStorage Physical disk warning.
1.3.6.1.4.1.674.10892.6.5.4347Nodealert2StoragePhysicalDiskInformationStorage Physical disk information.
1.3.6.1.4.1.674.10892.6.5.4353Nodealert2StorageVirtualDiskFailureStorage Virtual disk failure.
1.3.6.1.4.1.674.10892.6.5.4354Nodealert2StorageVirtualDiskWarningStorage Virtual disk warning.
1.3.6.1.4.1.674.10892.6.5.4355Nodealert2StorageVirtualDiskInformationStorage Virtual disk information.
1.3.6.1.4.1.674.10892.6.5.4433Nodealert2StorageSecurityFailureStorage Security failure or critical event.
1.3.6.1.4.1.674.10892.6.5.4434Nodealert2StorageSecurityWarningStorage Security warning.
1.3.6.1.4.1.674.10892.6.5.4435Nodealert2StorageSecurityInformationStorage Security information.
1.3.6.1.4.1.674.10892.6.5.6314Nodealert2SoftwareChangeUpdateWarningSoftware change update warning.
1.3.6.1.4.1.674.10892.6.5.8329Nodealert2PowerSupplyAuditFailurePower Supply audit failure or critical event.
1.3.6.1.4.1.674.10892.6.5.8330Nodealert2PowerSupplyAuditWarningPower Supply audit warning.
1.3.6.1.4.1.674.10892.6.5.8361Nodealert2SoftwareChangeAuditFailureSoftware change audit failure or critical event.
1.3.6.1.4.1.674.10892.6.5.8417Nodealert2PowerUsageAuditFailurePower usage audit failure or critical event.
1.3.6.1.4.1.674.10892.6.5.8418Nodealert2PowerUsageAuditWarningPower usage audit warning.
1.3.6.1.4.1.674.10892.6.5.8419Nodealert2PowerUsageAuditInformationPower usage audit information.
1.3.6.1.4.1.674.10892.6.5.8513Nodealert2LicenseFailureLicense failure.
1.3.6.1.4.1.674.10892.6.5.8514Nodealert2LicenseWarningLicense warning.
1.3.6.1.4.1.674.10892.6.5.8515Nodealert2LicenseInformationLicense information.
1.3.6.1.4.1.674.10892.6.5.8562Nodealert2PCIDeviceAuditWarningPCI device audit warning.
1.3.6.1.4.1.674.10892.6.5.8689Nodealert2CMCAuditFailureChassis Management Module audit failure or critical event.
1.3.6.1.4.1.674.10892.6.5.8690Nodealert2CMCAuditWarningChassis Management Module audit warning.
1.3.6.1.4.1.674.10892.6.5.8691Nodealert2CMCAuditInformationChassis Management Module audit information.
1.3.6.1.4.1.674.10892.6.5.8698Nodealert2IOVirtualizationAuditWarningIO Virtualization audit warning.
1.3.6.1.4.1.674.10892.6.5.10395Nodealert2CMCTestTrapTest trap generated in response to a user request.
1.3.6.1.4.1.674.10892.6.5.10529Nodealert2SWCConfigurationFailureSoftware configuration failure.
1.3.6.1.4.1.674.10892.6.5.10530Nodealert2SWCConfigurationWarningSoftware configuration warning.
1.3.6.1.4.1.674.10892.6.5.10611Nodealert2PCIDeviceConfigurationInformationPCI device configuration information.
1.3.6.1.4.1.674.10892.6.5.10746Nodealert2IOVConfigurationWarningIO Virtualization configuration warning.
1.3.6.1.4.1.674.10892.6.5.10747Nodealert2IOVConfigurationInformationIO Virtualization configuration information.
1.3.6.1.4.1.674.10892.6.6NodedmmGenericAlertGroup
1.3.6.1.4.1.674.10892.6.6.1NodedmmGenericAlertVariables
1.3.6.1.4.1.674.10892.6.6.1.1ScalardmmDeviceServiceTagread-onlymandatoryService tag of the device.
1.3.6.1.4.1.674.10892.6.6.100NodealertGenericCriticalMM generic critical system alert.
1.3.6.1.4.1.674.10892.6.6.200NodealertGenericWarningMM generic warning system alert.
1.3.6.1.4.1.674.10892.6.6.300NodealertGenericNormalMM generic normal system alert.
1.3.6.1.4.1.674.10892.6.6.400NodealertGenericInformationalMM generic information system alert.
1.3.6.1.4.1.674.10892.6.6.500NodealertGenericTestTrapEventMM Generated a test trap event in response to a user request.