DELL-MM-MIB-SMIv2
194 objects
No module-level DESCRIPTION found.
Imported Objects
| SNMPv2-CONF | NOTIFICATION-GROUP OBJECT-GROUP |
| SNMPv2-SMI | enterprises MODULE-IDENTITY NOTIFICATION-TYPE OBJECT-TYPE |
| SNMPv2-TC | DisplayString TEXTUAL-CONVENTION |
| OID | Name | Access | Status | Description |
|---|---|---|---|---|
| 1.3.6.1.4.1.674 | Nodedell | |||
| 1.3.6.1.4.1.674.10892 | Nodeserver3 | |||
| 1.3.6.1.4.1.674.10892.6 | NodedmmOutOfBandGroup | |||
| 1.3.6.1.4.1.674.10892.6.1 | NodedmmInformationGroup | |||
| 1.3.6.1.4.1.674.10892.6.1.1 | NodedmmProductInfoGroup | |||
| 1.3.6.1.4.1.674.10892.6.1.1.1 | ScalardmmProductName | read-only | current | This attribute defines the product name of a chassis management module. |
| 1.3.6.1.4.1.674.10892.6.1.1.2 | ScalardmmProductShortName | read-only | current | This attribute defines the short product name of a chassis management module. |
| 1.3.6.1.4.1.674.10892.6.1.1.3 | ScalardmmProductDescription | read-only | current | This attribute defines the product description of a chassis management module. |
| 1.3.6.1.4.1.674.10892.6.1.1.4 | ScalardmmProductManufacturer | read-only | current | This attribute defines the product manufacturer of a chassis management module. |
| 1.3.6.1.4.1.674.10892.6.1.1.5 | ScalardmmProductVersion | read-only | current | This attribute defines the product version of a chassis management module. |
| 1.3.6.1.4.1.674.10892.6.1.1.6 | ScalardmmChassisServiceTag | read-only | current | This attribute defines the Service Tag of the chassis. |
| 1.3.6.1.4.1.674.10892.6.1.1.7 | ScalardmmProductURL | read-only | current | This attribute defines the out-of-band UI URL of a chassis management module. |
| 1.3.6.1.4.1.674.10892.6.1.1.8 | ScalardmmProductChassisAssetTag | read-only | current | This attribute defines the Asset Tag of the chassis. |
| 1.3.6.1.4.1.674.10892.6.1.1.9 | ScalardmmProductChassisName | read-only | current | This attribute defines the name of the chassis. |
| 1.3.6.1.4.1.674.10892.6.1.1.10 | ScalardmmProductType | read-only | current | This attribute defines type of a remote management module |
| 1.3.6.1.4.1.674.10892.6.1.1.11 | ScalardmmProductChassisDataCenter | read-only | current | This attribute defines the Data Center locator of the chassis. |
| 1.3.6.1.4.1.674.10892.6.1.1.12 | ScalardmmProductChassisAisle | read-only | current | This attribute defines the Aisle locator of the chassis. |
| 1.3.6.1.4.1.674.10892.6.1.1.13 | ScalardmmProductChassisRack | read-only | current | This attribute defines the Rack locator of the chassis. |
| 1.3.6.1.4.1.674.10892.6.1.1.14 | ScalardmmProductChassisRackSlot | read-only | current | This attribute defines the Rack Slot locator of the chassis. |
| 1.3.6.1.4.1.674.10892.6.1.1.15 | ScalardmmProductChassisModel | read-only | current | This attribute defines the Model of the chassis. |
| 1.3.6.1.4.1.674.10892.6.1.1.16 | ScalardmmProductChassisExpressServiceCode | read-only | current | This attribute defines the Express Service Code of the chassis. |
| 1.3.6.1.4.1.674.10892.6.1.1.17 | ScalardmmProductChassisSystemID | read-only | current | This attribute defines the System ID of the chassis. |
| 1.3.6.1.4.1.674.10892.6.1.2 | NodedmmFirmwareGroup | |||
| 1.3.6.1.4.1.674.10892.6.1.2.1 | ScalardmmFirmwareVersion | read-only | current | This attribute defines the firmware version of chassis management module 1. |
| 1.3.6.1.4.1.674.10892.6.1.2.2 | ScalardmmFirmwareVersion2 | read-only | current | This attribute defines the firmware version of chassis management module 2. |
| 1.3.6.1.4.1.674.10892.6.2 | NodedmmStatusGroup | |||
| 1.3.6.1.4.1.674.10892.6.2.1 | ScalardmmGlobalSystemStatus | read-only | current | This attribute defines the overall chassis status being monitored by the chassis management module. |
| 1.3.6.1.4.1.674.10892.6.3 | NodedmmChassisStatusGroup | |||
| 1.3.6.1.4.1.674.10892.6.3.1 | NodedmmStatusNowGroup | |||
| 1.3.6.1.4.1.674.10892.6.3.1.1 | ScalardmmIOMCurrStatus | read-only | current | This attribute defines the IOM subsystem status being monitored by the chassis management module. |
| 1.3.6.1.4.1.674.10892.6.3.1.2 | ScalardmmRedCurrStatus | read-only | current | This attribute defines the Redundancy status being monitored by the chassis management module. |
| 1.3.6.1.4.1.674.10892.6.3.1.3 | ScalardmmPowerCurrStatus | read-only | current | This attribute defines the power subsystem health status being monitored by the chassis management module. |
| 1.3.6.1.4.1.674.10892.6.3.1.4 | ScalardmmFanCurrStatus | read-only | current | This attribute defines the Fan subsystem health status being monitored by the chassis management module. |
| 1.3.6.1.4.1.674.10892.6.3.1.5 | ScalardmmBladeCurrStatus | read-only | current | This attribute defines the Blade subsystem health status being monitored by the chassis management module. |
| 1.3.6.1.4.1.674.10892.6.3.1.6 | ScalardmmTempCurrStatus | read-only | current | This attribute defines the Temp Sensor subsystem health status being monitored by the chassis management module. |
| 1.3.6.1.4.1.674.10892.6.3.1.7 | ScalardmmMMCurrStatus | read-only | current | This attribute defines the health status being monitored by the chassis management module. |
| 1.3.6.1.4.1.674.10892.6.3.1.8 | ScalardmmChassisFrontPanelAmbientTemperature | read-only | current | This attribute defines the ambient temperature reading (in degrees Celsius) for the chassis front panel module. |
| 1.3.6.1.4.1.674.10892.6.4 | NodedmmChassisPowerGroup | |||
| 1.3.6.1.4.1.674.10892.6.4.1 | TabledmmPowerTable | not-accessible | current | This object defines the power table. |
| 1.3.6.1.4.1.674.10892.6.4.1.1 | RowdmmPowerTableEntry | not-accessible | current | This object defines the power table entry. |
| 1.3.6.1.4.1.674.10892.6.4.1.1.1 | ColumndmmPowerChassisIndex | read-only | current | This attribute defines the index (one-based) of the associated chassis. |
| 1.3.6.1.4.1.674.10892.6.4.1.1.2 | ColumndmmPowerIdlePower | read-only | current | This attribute defines the power (in Watts) required by the chassis infrastructure, plus the sum of the minimum power requirements for all currently powered-on… |
| 1.3.6.1.4.1.674.10892.6.4.1.1.3 | ColumndmmPowerKWhCumulative | read-only | current | This attribute defines the cumulative chassis power usage (in KWh) since last reset. |
| 1.3.6.1.4.1.674.10892.6.4.1.1.4 | ColumndmmPowerKWhCumulativeTime | read-only | current | This attribute defines the timestamp of the most recent chassis power accumulator reset. |
| 1.3.6.1.4.1.674.10892.6.4.1.1.5 | ColumndmmPowerWattsPeakUsage | read-only | current | This attribute defines the chassis peak power usage (in Watts) since last reset. |
| 1.3.6.1.4.1.674.10892.6.4.1.1.6 | ColumndmmPowerWattsPeakTime | read-only | current | This attribute defines the timestamp of the most recent chassis peak power usage. |
| 1.3.6.1.4.1.674.10892.6.4.1.1.7 | ColumndmmPowerWattsMinUsage | read-only | current | This attribute defines the chassis mimimum power usage (in Watts) since last reset. |
| 1.3.6.1.4.1.674.10892.6.4.1.1.8 | ColumndmmPowerWattsMinTime | read-only | current | This attribute defines the timestamp of the most recent chassis minimum power usage. |
| 1.3.6.1.4.1.674.10892.6.4.1.1.9 | ColumndmmPowerWattsReading | read-only | current | This attribute defines the instantaneous chassis power usage (in Watts). |
| 1.3.6.1.4.1.674.10892.6.4.2 | TabledmmPSUTable | not-accessible | current | This object defines the PSU table. |
| 1.3.6.1.4.1.674.10892.6.4.2.1 | RowdmmPSUTableEntry | not-accessible | current | This object defines the PSU table entry. |
| 1.3.6.1.4.1.674.10892.6.4.2.1.1 | ColumndmmPSUChassisIndex | read-only | current | This attribute defines the index (one-based) of the associated chassis. |
| 1.3.6.1.4.1.674.10892.6.4.2.1.2 | ColumndmmPSUIndex | read-only | current | This attribute defines the index (one-based) of the associated PSU. |
| 1.3.6.1.4.1.674.10892.6.4.2.1.3 | ColumndmmPSULocation | read-only | current | This attribute defines the location of the PSU. |
| 1.3.6.1.4.1.674.10892.6.4.2.1.4 | ColumndmmPSUState | read-only | current | This attribute defines the enabled state of of the PSU. |
| 1.3.6.1.4.1.674.10892.6.4.2.1.5 | ColumndmmPSUType | read-only | current | This attribute defines the type of the PSU. |
| 1.3.6.1.4.1.674.10892.6.4.2.1.6 | ColumndmmPSUCapacity | read-only | current | This attribute defines the capacity in watts of the PSU. |
| 1.3.6.1.4.1.674.10892.6.4.2.1.7 | ColumndmmPSUVoltage | read-only | current | This attribute defines the input voltage of the PSU. |
| 1.3.6.1.4.1.674.10892.6.4.2.1.8 | ColumndmmPSUCurrStatus | read-only | current | This attribute defines the current status of the PSU. |
| 1.3.6.1.4.1.674.10892.6.5 | NodedmmChassisAlert2Group | |||
| 1.3.6.1.4.1.674.10892.6.5.0.2153 | Notificationalert2FanFailure | current | Fan failure. | |
| 1.3.6.1.4.1.674.10892.6.5.0.2154 | Notificationalert2FanWarning | current | Fan warning. | |
| 1.3.6.1.4.1.674.10892.6.5.0.2155 | Notificationalert2FanInformation | current | Fan information. | |
| 1.3.6.1.4.1.674.10892.6.5.0.2161 | Notificationalert2TemperatureProbeFailure | current | Temperature sensor has detected a failure value. | |
| 1.3.6.1.4.1.674.10892.6.5.0.2162 | Notificationalert2TemperatureProbeWarning | current | Temperature sensor has detected a warning value. | |
| 1.3.6.1.4.1.674.10892.6.5.0.2163 | Notificationalert2TemperatureProbeNormal | current | Temperature sensor value is within range. | |
| 1.3.6.1.4.1.674.10892.6.5.0.2169 | Notificationalert2VoltageProbeFailure | current | Voltage sensor has detected a failure value. | |
| 1.3.6.1.4.1.674.10892.6.5.0.2170 | Notificationalert2VoltageProbeWarning | current | Voltage sensor has detected a warning value. | |
| 1.3.6.1.4.1.674.10892.6.5.0.2171 | Notificationalert2VoltageProbeNormal | current | Voltage sensor reading is within range. | |
| 1.3.6.1.4.1.674.10892.6.5.0.2177 | Notificationalert2AmperageProbeFailure | current | Current sensor has detected a failure value. | |
| 1.3.6.1.4.1.674.10892.6.5.0.2178 | Notificationalert2AmperageProbeWarning | current | Current sensor has detected a warning value. | |
| 1.3.6.1.4.1.674.10892.6.5.0.2179 | Notificationalert2AmperageProbeNormal | current | Current sensor reading is within range. | |
| 1.3.6.1.4.1.674.10892.6.5.0.2185 | Notificationalert2PowerSupplyFailure | current | Power supply has detected a failure. | |
| 1.3.6.1.4.1.674.10892.6.5.0.2186 | Notificationalert2PowerSupplyWarning | current | Power supply has detected a warning. | |
| 1.3.6.1.4.1.674.10892.6.5.0.2187 | Notificationalert2PowerSupplyNormal | current | Power supply has returned to normal. | |
| 1.3.6.1.4.1.674.10892.6.5.0.2225 | Notificationalert2BatteryFailure | current | Battery has failed or battery is absent. | |
| 1.3.6.1.4.1.674.10892.6.5.0.2226 | Notificationalert2BatteryWarning | current | Battery is low. | |
| 1.3.6.1.4.1.674.10892.6.5.0.2227 | Notificationalert2BatteryNormal | current | Battery state has returned to normal; or battery presence had been detected. | |
| 1.3.6.1.4.1.674.10892.6.5.0.2249 | Notificationalert2LinkStatusFailure | current | Link status failure or critical event. | |
| 1.3.6.1.4.1.674.10892.6.5.0.2250 | Notificationalert2LinkStatusWarning | current | Link status warning. | |
| 1.3.6.1.4.1.674.10892.6.5.0.2251 | Notificationalert2LinkStatusInformation | current | Link status information. | |
| 1.3.6.1.4.1.674.10892.6.5.0.2273 | Notificationalert2PowerUsageFailure | current | Power usage failure. | |
| 1.3.6.1.4.1.674.10892.6.5.0.2274 | Notificationalert2PowerUsageWarning | current | Power usage warning. | |
| 1.3.6.1.4.1.674.10892.6.5.0.2275 | Notificationalert2PowerUsageInformation | current | Power usage information. | |
| 1.3.6.1.4.1.674.10892.6.5.0.2329 | Notificationalert2HardwareConfigurationFailure | current | Hardware configuration failure or critical event. | |
| 1.3.6.1.4.1.674.10892.6.5.0.2330 | Notificationalert2HardwareConfigurationWarning | current | Hardware configuration warning. | |
| 1.3.6.1.4.1.674.10892.6.5.0.2331 | Notificationalert2HardwareConfigurationInformation | current | Hardware configuration information. | |
| 1.3.6.1.4.1.674.10892.6.5.0.2337 | Notificationalert2SoftwareConfigurationFailure | current | Software configuration failure. | |
| 1.3.6.1.4.1.674.10892.6.5.0.2338 | Notificationalert2SoftwareConfigurationWarning | current | Software configuration warning. | |
| 1.3.6.1.4.1.674.10892.6.5.0.2339 | Notificationalert2SoftwareConfigurationInformation | current | Software configuration information. | |
| 1.3.6.1.4.1.674.10892.6.5.0.2377 | Notificationalert2SystemEventLogFailure | current | System Event Log failure or critical event. | |
| 1.3.6.1.4.1.674.10892.6.5.0.2378 | Notificationalert2SystemEventLogWarning | current | System Event Log warning. | |
| 1.3.6.1.4.1.674.10892.6.5.0.2379 | Notificationalert2SystemEventLogInformation | current | System Event Log information. | |
| 1.3.6.1.4.1.674.10892.6.5.0.2385 | Notificationalert2SecurityFailure | current | Security failure or critical event. | |
| 1.3.6.1.4.1.674.10892.6.5.0.2386 | Notificationalert2SecurityWarning | current | Security warning. | |
| 1.3.6.1.4.1.674.10892.6.5.0.2387 | Notificationalert2SecurityInformation | current | Security information. | |
| 1.3.6.1.4.1.674.10892.6.5.0.2393 | Notificationalert2CableFailure | current | Cable failure. | |
| 1.3.6.1.4.1.674.10892.6.5.0.2465 | Notificationalert2PowerSupplyAbsent | current | Power supply is absent. | |
| 1.3.6.1.4.1.674.10892.6.5.0.2473 | Notificationalert2RedundancyLost | current | Redundancy is lost. | |
| 1.3.6.1.4.1.674.10892.6.5.0.2474 | Notificationalert2RedundancyDegraded | current | Redundancy is degraded. | |
| 1.3.6.1.4.1.674.10892.6.5.0.2475 | Notificationalert2RedundancyInformation | current | Redundancy information. | |
| 1.3.6.1.4.1.674.10892.6.5.0.2545 | Notificationalert2CMCFailure | current | Chassis Management Module detected an error. | |
| 1.3.6.1.4.1.674.10892.6.5.0.2546 | Notificationalert2CMCWarning | current | Chassis Management Module detected a warning. | |
| 1.3.6.1.4.1.674.10892.6.5.0.2553 | Notificationalert2IOVirtualizationFailure | current | IO Virtualization failure or critical event. | |
| 1.3.6.1.4.1.674.10892.6.5.0.2554 | Notificationalert2IOVirtualizationWarning | current | IO Virtualization warning. | |
| 1.3.6.1.4.1.674.10892.6.5.0.2555 | Notificationalert2IOVirtualizationInformation | current | IO Virtualization information. | |
| 1.3.6.1.4.1.674.10892.6.5.0.4177 | Notificationalert2StorageManagementFailure | current | Storage Management has detected a device independent error condition. There is no global status change associated with this trap. | |
| 1.3.6.1.4.1.674.10892.6.5.0.4178 | Notificationalert2StorageManagementWarning | current | Storage Management has detected a device independent warning condition. There is no global status change associated with this trap. | |
| 1.3.6.1.4.1.674.10892.6.5.0.4179 | Notificationalert2StorageManagementInformation | current | Storage Management information. There is no global status change associated with this trap. | |
| 1.3.6.1.4.1.674.10892.6.5.0.4201 | Notificationalert2StorageFanFailure | current | Storage Fan failure. | |
| 1.3.6.1.4.1.674.10892.6.5.0.4202 | Notificationalert2StorageFanWarning | current | Storage Fan warning. | |
| 1.3.6.1.4.1.674.10892.6.5.0.4203 | Notificationalert2StorageFanInformation | current | Storage Fan information. | |
| 1.3.6.1.4.1.674.10892.6.5.0.4209 | Notificationalert2StorageTemperatureProbeFailure | current | Storage Temperature probe failure. | |
| 1.3.6.1.4.1.674.10892.6.5.0.4210 | Notificationalert2StorageTemperatureProbeWarning | current | Storage Temperature probe warning. | |
| 1.3.6.1.4.1.674.10892.6.5.0.4211 | Notificationalert2StorageTemperatureProbeInformation | current | Storage Temperature probe information. | |
| 1.3.6.1.4.1.674.10892.6.5.0.4233 | Notificationalert2StoragePowerSupplyFailure | current | Storage Power supply failure. | |
| 1.3.6.1.4.1.674.10892.6.5.0.4234 | Notificationalert2StoragePowerSupplyWarning | current | Storage Power supply warning. | |
| 1.3.6.1.4.1.674.10892.6.5.0.4235 | Notificationalert2StoragePowerSupplyInformation | current | Storage Power supply information. | |
| 1.3.6.1.4.1.674.10892.6.5.0.4273 | Notificationalert2StorageBatteryFailure | current | Storage Battery failure. | |
| 1.3.6.1.4.1.674.10892.6.5.0.4274 | Notificationalert2StorageBatteryWarning | current | Storage Battery warning. | |
| 1.3.6.1.4.1.674.10892.6.5.0.4275 | Notificationalert2StorageBatteryInformation | current | Storage Battery information. | |
| 1.3.6.1.4.1.674.10892.6.5.0.4329 | Notificationalert2StorageControllerFailure | current | Storage Controller failure. | |
| 1.3.6.1.4.1.674.10892.6.5.0.4330 | Notificationalert2StorageControllerWarning | current | Storage Controller warning. | |
| 1.3.6.1.4.1.674.10892.6.5.0.4331 | Notificationalert2StorageControllerInformation | current | Storage Controller information. | |
| 1.3.6.1.4.1.674.10892.6.5.0.4337 | Notificationalert2StorageEnclosureFailure | current | Storage Enclosure failure. | |
| 1.3.6.1.4.1.674.10892.6.5.0.4338 | Notificationalert2StorageEnclosureWarning | current | Storage Enclosure warning. | |
| 1.3.6.1.4.1.674.10892.6.5.0.4339 | Notificationalert2StorageEnclosureInformation | current | Storage Enclosure information. | |
| 1.3.6.1.4.1.674.10892.6.5.0.4345 | Notificationalert2StoragePhysicalDiskFailure | current | Storage Physical disk failure. | |
| 1.3.6.1.4.1.674.10892.6.5.0.4346 | Notificationalert2StoragePhysicalDiskWarning | current | Storage Physical disk warning. | |
| 1.3.6.1.4.1.674.10892.6.5.0.4347 | Notificationalert2StoragePhysicalDiskInformation | current | Storage Physical disk information. | |
| 1.3.6.1.4.1.674.10892.6.5.0.4353 | Notificationalert2StorageVirtualDiskFailure | current | Storage Virtual disk failure. | |
| 1.3.6.1.4.1.674.10892.6.5.0.4354 | Notificationalert2StorageVirtualDiskWarning | current | Storage Virtual disk warning. | |
| 1.3.6.1.4.1.674.10892.6.5.0.4355 | Notificationalert2StorageVirtualDiskInformation | current | Storage Virtual disk information. | |
| 1.3.6.1.4.1.674.10892.6.5.0.4433 | Notificationalert2StorageSecurityFailure | current | Storage Security failure or critical event. | |
| 1.3.6.1.4.1.674.10892.6.5.0.4434 | Notificationalert2StorageSecurityWarning | current | Storage Security warning. | |
| 1.3.6.1.4.1.674.10892.6.5.0.4435 | Notificationalert2StorageSecurityInformation | current | Storage Security information. | |
| 1.3.6.1.4.1.674.10892.6.5.0.6314 | Notificationalert2SoftwareChangeUpdateWarning | current | Software change update warning. | |
| 1.3.6.1.4.1.674.10892.6.5.0.8329 | Notificationalert2PowerSupplyAuditFailure | current | Power Supply audit failure or critical event. | |
| 1.3.6.1.4.1.674.10892.6.5.0.8330 | Notificationalert2PowerSupplyAuditWarning | current | Power Supply audit warning. | |
| 1.3.6.1.4.1.674.10892.6.5.0.8361 | Notificationalert2SoftwareChangeAuditFailure | current | Software change audit failure or critical event. | |
| 1.3.6.1.4.1.674.10892.6.5.0.8417 | Notificationalert2PowerUsageAuditFailure | current | Power usage audit failure or critical event. | |
| 1.3.6.1.4.1.674.10892.6.5.0.8418 | Notificationalert2PowerUsageAuditWarning | current | Power usage audit warning. | |
| 1.3.6.1.4.1.674.10892.6.5.0.8419 | Notificationalert2PowerUsageAuditInformation | current | Power usage audit information. | |
| 1.3.6.1.4.1.674.10892.6.5.0.8513 | Notificationalert2LicenseFailure | current | License failure. | |
| 1.3.6.1.4.1.674.10892.6.5.0.8514 | Notificationalert2LicenseWarning | current | License warning. | |
| 1.3.6.1.4.1.674.10892.6.5.0.8515 | Notificationalert2LicenseInformation | current | License information. | |
| 1.3.6.1.4.1.674.10892.6.5.0.8562 | Notificationalert2PCIDeviceAuditWarning | current | PCI device audit warning. | |
| 1.3.6.1.4.1.674.10892.6.5.0.8689 | Notificationalert2CMCAuditFailure | current | Chassis Management Module audit failure or critical event. | |
| 1.3.6.1.4.1.674.10892.6.5.0.8690 | Notificationalert2CMCAuditWarning | current | Chassis Management Module audit warning. | |
| 1.3.6.1.4.1.674.10892.6.5.0.8691 | Notificationalert2CMCAuditInformation | current | Chassis Management Module audit information. | |
| 1.3.6.1.4.1.674.10892.6.5.0.8698 | Notificationalert2IOVirtualizationAuditWarning | current | IO Virtualization audit warning. | |
| 1.3.6.1.4.1.674.10892.6.5.0.10395 | Notificationalert2CMCTestTrap | current | Test trap generated in response to a user request. | |
| 1.3.6.1.4.1.674.10892.6.5.0.10529 | Notificationalert2SWCConfigurationFailure | current | Software configuration failure. | |
| 1.3.6.1.4.1.674.10892.6.5.0.10530 | Notificationalert2SWCConfigurationWarning | current | Software configuration warning. | |
| 1.3.6.1.4.1.674.10892.6.5.0.10611 | Notificationalert2PCIDeviceConfigurationInformation | current | PCI device configuration information. | |
| 1.3.6.1.4.1.674.10892.6.5.0.10746 | Notificationalert2IOVConfigurationWarning | current | IO Virtualization configuration warning. | |
| 1.3.6.1.4.1.674.10892.6.5.0.10747 | Notificationalert2IOVConfigurationInformation | current | IO Virtualization configuration information. | |
| 1.3.6.1.4.1.674.10892.6.5.1 | NodedmmChassisAlert2Variables | |||
| 1.3.6.1.4.1.674.10892.6.5.1.1 | ScalardmmCA2MessageID | read-only | current | Message ID of the alert. |
| 1.3.6.1.4.1.674.10892.6.5.1.2 | ScalardmmCA2Message | read-only | mandatory | Message describing the alert. |
| 1.3.6.1.4.1.674.10892.6.5.1.3 | ScalardmmCA2MessageArgs | read-only | current | Concatenated set of strings representing any message arguments that were used to construct the alert message. Each message argument string is enclosed in doubl… |
| 1.3.6.1.4.1.674.10892.6.5.1.4 | ScalardmmCA2AlertStatus | read-only | current | Status of the alert. |
| 1.3.6.1.4.1.674.10892.6.5.1.5 | ScalardmmCA2FQDD | read-only | current | Fully qualified device descriptor of device causing the alert. |
| 1.3.6.1.4.1.674.10892.6.6 | NodedmmGenericAlertGroup | |||
| 1.3.6.1.4.1.674.10892.6.6.0.100 | NotificationalertGenericCritical | current | MM generic critical system alert. | |
| 1.3.6.1.4.1.674.10892.6.6.0.200 | NotificationalertGenericWarning | current | MM generic warning system alert. | |
| 1.3.6.1.4.1.674.10892.6.6.0.300 | NotificationalertGenericNormal | current | MM generic normal system alert. | |
| 1.3.6.1.4.1.674.10892.6.6.0.400 | NotificationalertGenericInformational | current | MM generic information system alert. | |
| 1.3.6.1.4.1.674.10892.6.6.0.500 | NotificationalertGenericTestTrapEvent | current | MM Generated a test trap event in response to a user request. | |
| 1.3.6.1.4.1.674.10892.6.6.1 | NodedmmGenericAlertVariables | |||
| 1.3.6.1.4.1.674.10892.6.6.1.1 | ScalardmmDeviceServiceTag | read-only | current | Service tag of the device. |
| 1.3.6.1.4.1.674.10892.6.7 | NodeconformanceGroup | |||
| 1.3.6.1.4.1.674.10892.6.7.1 | NodeconformanceMIBGroups | |||
| 1.3.6.1.4.1.674.10892.6.7.1.1 | GroupdmmProductInfoObjGroup | current | A collection of objects providing information about the chassis management module. | |
| 1.3.6.1.4.1.674.10892.6.7.1.2 | GroupdmmFirmwareObjGroup | current | A collection of objects providing information about the chassis firmware version. | |
| 1.3.6.1.4.1.674.10892.6.7.1.3 | GroupdmmStatusObjGroup | current | Object is providing information about the overall chassis status. | |
| 1.3.6.1.4.1.674.10892.6.7.1.4 | GroupdmmStatusNowObjGroup | current | A collection of objects providing information about the chassis subsystem status. | |
| 1.3.6.1.4.1.674.10892.6.7.1.5 | GroupdmmChassisPowerObjGroup | current | A collection of objects providing information about the chassis Power. | |
| 1.3.6.1.4.1.674.10892.6.7.1.6 | GroupdmmPowerTableObjEntry | current | A collection of objects providing information about the chassis Power Information. | |
| 1.3.6.1.4.1.674.10892.6.7.1.7 | GroupdmmPSUTableObjEntry | current | A collection of objects providing information about the chassis Power Supply. | |
| 1.3.6.1.4.1.674.10892.6.7.1.8 | GroupdmmChassisAlert2VariablesObj | current | A collection of objects providing information about the chassis Alerts. | |
| 1.3.6.1.4.1.674.10892.6.7.1.9 | GroupdmmGenericAlertVariablesObj | current | A collection of objects providing information about the chassis Alerts. | |
| 1.3.6.1.4.1.674.10892.6.7.2 | NodeconformanceMIBnotificationGroup | |||
| 1.3.6.1.4.1.674.10892.6.7.2.1 | GroupdmmChassisAlert2NotificationGroup | current | The two notifications which an SNMPv2 entity is required to implement. | |
| 1.3.6.1.4.1.674.10892.6.7.2.2 | GroupdmmGenericAlertNotificationGroup | current | The two notifications which an SNMPv2 entity is required to implement. |
Type Definitions
| Name | Syntax | Status | Description |
|---|---|---|---|
| DellMmType | INTEGER { other(1), unknown(2), mxMM(3) } | current | Management Module Types. |
| DellPowerIndexRange | INTEGER (1..1) | current | Integer with a range of (1..1). |
| DellPowerReading | OCTET STRING (SIZE (0..32)) | current | Power Reading. |
| DellPSUCapable | INTEGER { absent(1), none(2), basic(3) } | current | Power Supply Information. |
| DellPSUIndexRange | INTEGER (1..6) | current | Integer with a range of (1..6). |
| DellStatus | INTEGER { other(1), unknown(2), ok(3), nonCritical(4), critical(5), nonRecoverable(6) } | current | Status Information. |
| DellString | OCTET STRING (SIZE (0..1023)) | current | General string type. |
| DellTemperatureReading | INTEGER | current | Temperature Reading. |
| DellTimestamp | OCTET STRING (SIZE (26)) | current | Time Stamp. |