DELL-RAC-MIB
446 objects
No module-level DESCRIPTION found.
Imported Objects
| RFC-1212 | OBJECT-TYPE |
| RFC-1215 | TRAP-TYPE |
| RFC1155-SMI | enterprises TimeTicks |
| RFC1213-MIB | DisplayString |
| OID | Name | Access | Status | Description |
|---|---|---|---|---|
| 1.3.6.1.4.1.674 | Nodedell | |||
| 1.3.6.1.4.1.674.10892 | Nodeserver3 | |||
| 1.3.6.1.4.1.674.10892.2 | NodedrsOutofBandGroup | |||
| 1.3.6.1.4.1.674.10892.2.1 | NodedrsInformationGroup | |||
| 1.3.6.1.4.1.674.10892.2.1.1 | NodedrsProductInfoGroup | |||
| 1.3.6.1.4.1.674.10892.2.1.1.1 | ScalardrsProductName | read-only | mandatory | 0001.0001.0001 This attribute defines the product name of a chassis management controller. |
| 1.3.6.1.4.1.674.10892.2.1.1.2 | ScalardrsProductShortName | read-only | mandatory | 0001.0001.0002 This attribute defines the short product name of a chassis management controller. |
| 1.3.6.1.4.1.674.10892.2.1.1.3 | ScalardrsProductDescription | read-only | mandatory | 0001.0001.0003 This attribute defines the product description of a chassis management controller. |
| 1.3.6.1.4.1.674.10892.2.1.1.4 | ScalardrsProductManufacturer | read-only | mandatory | 0001.0001.0004 This attribute defines the product manufacturer of a chassis management controller. |
| 1.3.6.1.4.1.674.10892.2.1.1.5 | ScalardrsProductVersion | read-only | mandatory | 0001.0001.0005 This attribute defines the product version of a chassis management controller. |
| 1.3.6.1.4.1.674.10892.2.1.1.6 | ScalardrsChassisServiceTag | read-only | mandatory | 0001.0001.0007 This attribute defines the Service Tag of the chassis. |
| 1.3.6.1.4.1.674.10892.2.1.1.7 | ScalardrsProductURL | read-only | mandatory | 0001.0001.0006 This attribute defines the out-of-band UI URL of a chassis management controller. |
| 1.3.6.1.4.1.674.10892.2.1.1.8 | ScalardrsProductChassisAssetTag | read-only | mandatory | 0001.0001.0008 This attribute defines the Asset Tag of the chassis. |
| 1.3.6.1.4.1.674.10892.2.1.1.9 | ScalardrsProductChassisLocation | read-only | mandatory | 0001.0001.0009 This attribute defines the location of the chassis. |
| 1.3.6.1.4.1.674.10892.2.1.1.10 | ScalardrsProductChassisName | read-only | mandatory | 0001.0001.0010 This attribute defines the name of the chassis. |
| 1.3.6.1.4.1.674.10892.2.1.1.11 | ScalardrsSystemServiceTag | read-only | mandatory | 0001.0001.0011 This attribute defines the service tag of a system. |
| 1.3.6.1.4.1.674.10892.2.1.1.12 | ScalardrsProductSystemAssetTag | read-only | mandatory | 0001.0001.0012 This attribute defines the asset tag of a system. |
| 1.3.6.1.4.1.674.10892.2.1.1.13 | ScalardrsProductSystemSlot | read-only | mandatory | 0001.0001.0013 This attribute defines the slot number of a CMC. |
| 1.3.6.1.4.1.674.10892.2.1.1.14 | ScalardrsProductType | read-only | mandatory | 0001.0001.0014 This attribute defines type of a remote access card |
| 1.3.6.1.4.1.674.10892.2.1.1.15 | ScalardrsProductChassisDataCenter | read-only | mandatory | 0001.0001.0015 This attribute defines the Data Center locator of the chassis. |
| 1.3.6.1.4.1.674.10892.2.1.1.16 | ScalardrsProductChassisAisle | read-only | mandatory | 0001.0001.0016 This attribute defines the Aisle locator of the chassis. |
| 1.3.6.1.4.1.674.10892.2.1.1.17 | ScalardrsProductChassisRack | read-only | mandatory | 0001.0001.0017 This attribute defines the Rack locator of the chassis. |
| 1.3.6.1.4.1.674.10892.2.1.1.18 | ScalardrsProductChassisRackSlot | read-only | mandatory | 0001.0001.0018 This attribute defines the Rack Slot locator of the chassis. |
| 1.3.6.1.4.1.674.10892.2.1.1.19 | ScalardrsProductChassisModel | read-only | mandatory | 0001.0001.0019 This attribute defines the Model of the chassis. |
| 1.3.6.1.4.1.674.10892.2.1.1.20 | ScalardrsProductChassisExpressServiceCode | read-only | mandatory | 0001.0001.0020 This attribute defines the Express Service Code of the chassis. |
| 1.3.6.1.4.1.674.10892.2.1.1.21 | ScalardrsProductChassisSystemID | read-only | mandatory | 0001.0001.0021 This attribute defines the System ID of the chassis. |
| 1.3.6.1.4.1.674.10892.2.1.1.22 | ScalardrsProductChassisSize | read-only | mandatory | 0001.0001.0022 This attribute defines the size of the chassis in rack units (U). A U is a standard unit of measure for the height of a rack or rack-mountable c… |
| 1.3.6.1.4.1.674.10892.2.1.2 | NodedrsFirmwareGroup | |||
| 1.3.6.1.4.1.674.10892.2.1.2.1 | ScalardrsFirmwareVersion | read-only | mandatory | 0001.0002.0001 This attribute defines the firmware version of chassis management controller 1. |
| 1.3.6.1.4.1.674.10892.2.1.2.2 | ScalardrsiKVMFirmwareVersion | read-only | mandatory | 0001.0002.0002 This attribute defines the firmware version of the iKVM. |
| 1.3.6.1.4.1.674.10892.2.1.2.3 | ScalardrsFirmwareVersion2 | read-only | mandatory | 0001.0002.0003 This attribute defines the firmware version of chassis management controller 2. |
| 1.3.6.1.4.1.674.10892.2.2 | NodedrsStatusGroup | |||
| 1.3.6.1.4.1.674.10892.2.2.1 | ScalardrsGlobalSystemStatus | read-only | mandatory | 0002.0001.0001 This attribute defines the overall chassis status being monitored by the chassis management card. |
| 1.3.6.1.4.1.674.10892.2.3 | NodedrsChassisStatusGroup | |||
| 1.3.6.1.4.1.674.10892.2.3.1 | NodedrsStatusNowGroup | |||
| 1.3.6.1.4.1.674.10892.2.3.1.1 | ScalardrsGlobalCurrStatus | read-only | mandatory | 0003.0001.0001 This attribute defines the overall chassis status being monitored by the chassis management card. |
| 1.3.6.1.4.1.674.10892.2.3.1.2 | ScalardrsIOMCurrStatus | read-only | mandatory | 0003.0001.0002 This attribute defines the IOM subsystem status being monitored by the chassis management card. |
| 1.3.6.1.4.1.674.10892.2.3.1.3 | ScalardrsKVMCurrStatus | read-only | mandatory | 0003.0001.0003 This attribute defines the iKVM subsystem health status being monitored by the chassis management card. |
| 1.3.6.1.4.1.674.10892.2.3.1.4 | ScalardrsRedCurrStatus | read-only | mandatory | 0003.0001.0004 This attribute defines the Redundancy status being monitored by the chassis management card. |
| 1.3.6.1.4.1.674.10892.2.3.1.5 | ScalardrsPowerCurrStatus | read-only | mandatory | 0003.0001.0005 This attribute defines the power subsystem health status being monitored by the chassis management card. |
| 1.3.6.1.4.1.674.10892.2.3.1.6 | ScalardrsFanCurrStatus | read-only | mandatory | 0003.0001.0006 This attribute defines the Fan subsystem health status being monitored by the chassis management card. |
| 1.3.6.1.4.1.674.10892.2.3.1.7 | ScalardrsBladeCurrStatus | read-only | mandatory | 0003.0001.0007 This attribute defines the Blade subsystem health status being monitored by the chassis management card. |
| 1.3.6.1.4.1.674.10892.2.3.1.8 | ScalardrsTempCurrStatus | read-only | mandatory | 0003.0001.0008 This attribute defines the Temp Sensor subsystem health status being monitored by the chassis management card. |
| 1.3.6.1.4.1.674.10892.2.3.1.9 | ScalardrsCMCCurrStatus | read-only | mandatory | 0003.0001.0009 This attribute defines the CMC health status being monitored by the chassis management card. |
| 1.3.6.1.4.1.674.10892.2.3.1.10 | ScalardrsChassisFrontPanelAmbientTemperature | read-only | mandatory | 0003.0001.0010 This attribute defines the ambient temperature reading (in degrees Celsius) for the chassis front panel controller. |
| 1.3.6.1.4.1.674.10892.2.3.1.11 | ScalardrsCMCAmbientTemperature | read-only | mandatory | 0003.0001.0011 This attribute defines the ambient temperature reading (in degrees Celsius) for the chassis management card. |
| 1.3.6.1.4.1.674.10892.2.3.1.12 | ScalardrsCMCProcessorTemperature | read-only | mandatory | 0003.0001.0012 This attribute defines the temperature reading (in degrees Celsius) for the chassis management card processor. |
| 1.3.6.1.4.1.674.10892.2.3.2 | NodedrsStatusPrevGroup | |||
| 1.3.6.1.4.1.674.10892.2.3.2.1 | ScalardrsGlobalPrevStatus | read-only | mandatory | 0003.0002.0001 This attribute defines the previous chassis status recorded by the chassis management card. |
| 1.3.6.1.4.1.674.10892.2.3.2.2 | ScalardrsIOMPrevStatus | read-only | mandatory | 0003.0002.0002 This attribute defines the previous IOM subsystem status recorded by the chassis management card. |
| 1.3.6.1.4.1.674.10892.2.3.2.3 | ScalardrsKVMPrevStatus | read-only | mandatory | 0003.0002.0003 This attribute defines the previous iKVM subsystem health status recorded by the chassis management card. |
| 1.3.6.1.4.1.674.10892.2.3.2.4 | ScalardrsRedPrevStatus | read-only | mandatory | 0003.0002.0004 This attribute defines the previous Redundancy status recorded by the chassis management card. |
| 1.3.6.1.4.1.674.10892.2.3.2.5 | ScalardrsPowerPrevStatus | read-only | mandatory | 0003.0002.0005 This attribute defines the previous power subsystem health status recorded by the chassis management card. |
| 1.3.6.1.4.1.674.10892.2.3.2.6 | ScalardrsFanPrevStatus | read-only | mandatory | 0003.0002.0006 This attribute defines the previous Fan health status being monitored by the chassis management card. |
| 1.3.6.1.4.1.674.10892.2.3.2.7 | ScalardrsBladePrevStatus | read-only | mandatory | 0003.0002.0007 This attribute defines the previous Blade subsystem health status recorded by the chassis management card. |
| 1.3.6.1.4.1.674.10892.2.3.2.8 | ScalardrsTempPrevStatus | read-only | mandatory | 0003.0001.0008 This attribute defines the Temp Sensor health status being monitored by the chassis management card. |
| 1.3.6.1.4.1.674.10892.2.3.2.9 | ScalardrsCMCPrevStatus | read-only | mandatory | 0003.0001.0009 This attribute defines the CMC health status being monitored by the chassis management card. |
| 1.3.6.1.4.1.674.10892.2.3.3 | NodedrsStatusChangeGroup | |||
| 1.3.6.1.4.1.674.10892.2.3.3.1 | ScalardrsGlobalChangeTime | read-only | mandatory | 0003.0003.0001 This attribute defines the timestamp of the most recent global status change. |
| 1.3.6.1.4.1.674.10892.2.3.3.2 | ScalardrsIOMChangeTime | read-only | mandatory | 0003.0003.0002 This attribute defines the timestamp of the most recent IOM status change. |
| 1.3.6.1.4.1.674.10892.2.3.3.3 | ScalardrsKVMChangeTime | read-only | mandatory | 0003.0003.0003 This attribute defines the timestamp of the most recent iKVM status change. |
| 1.3.6.1.4.1.674.10892.2.3.3.4 | ScalardrsRedChangeTime | read-only | mandatory | 0003.0003.0004 This attribute defines the timestamp of the most recent Redundancy status change. |
| 1.3.6.1.4.1.674.10892.2.3.3.5 | ScalardrsPowerChangeTime | read-only | mandatory | 0003.0003.0005 This attribute defines the timestamp of the most recent power health status change. |
| 1.3.6.1.4.1.674.10892.2.3.3.6 | ScalardrsFanChangeTime | read-only | mandatory | 0003.0003.0006 This attribute defines the timestamp of the most recent Fan health status change. |
| 1.3.6.1.4.1.674.10892.2.3.3.7 | ScalardrsBladeChangeTime | read-only | mandatory | 0003.0003.0007 This attribute defines the timestamp of the most recent Blade health status change. |
| 1.3.6.1.4.1.674.10892.2.3.3.8 | ScalardrsTempChangeTime | read-only | mandatory | 0003.0003.0008 This attribute defines the timestamp of the most recent Temp Sensor health status change. |
| 1.3.6.1.4.1.674.10892.2.3.3.9 | ScalardrsCMCChangeTime | read-only | mandatory | 0003.0003.0009 This attribute defines the timestamp of the most recent CMC health status change. |
| 1.3.6.1.4.1.674.10892.2.4 | NodedrsChassisPowerGroup | |||
| 1.3.6.1.4.1.674.10892.2.4.1 | TabledrsCMCPowerTable | not-accessible | mandatory | 0004.0001 This object defines the CMC power table. |
| 1.3.6.1.4.1.674.10892.2.4.1.1 | RowdrsCMCPowerTableEntry | not-accessible | mandatory | 0004.0001.0001 This object defines the CMC power table entry. |
| 1.3.6.1.4.1.674.10892.2.4.1.1.1 | ColumndrsChassisIndex | read-only | mandatory | 0004.0001.0001.0001 This attribute defines the index (one-based) of the associated chassis. |
| 1.3.6.1.4.1.674.10892.2.4.1.1.2 | ColumndrsPotentialPower | read-only | mandatory | 0004.0001.0001.0002 This attribute defines the power (in Watts) required by the chassis infrastructure, plus the sum of the maximum power requirements for all … |
| 1.3.6.1.4.1.674.10892.2.4.1.1.3 | ColumndrsIdlePower | read-only | mandatory | 0004.0001.0001.0003 This attribute defines the power (in Watts) required by the chassis infrastructure, plus the sum of the minimum power requirements for all … |
| 1.3.6.1.4.1.674.10892.2.4.1.1.4 | ColumndrsMaxPowerSpecification | read-only | mandatory | 0004.0001.0001.0004 This attribute defines the power limit (in Watts) at which server throttling will take place. |
| 1.3.6.1.4.1.674.10892.2.4.1.1.5 | ColumndrsPowerSurplus | read-only | mandatory | 0004.0001.0001.0005 This attribute defines the power surplus (in Watts) remaining above the drsPotentialPower reading. |
| 1.3.6.1.4.1.674.10892.2.4.1.1.6 | ColumndrsKWhCumulative | read-only | mandatory | 0004.0001.0001.0006 This attribute defines the cumulative chassis power usage (in KWh) since last reset. |
| 1.3.6.1.4.1.674.10892.2.4.1.1.7 | ColumndrsKWhCumulativeTime | read-only | mandatory | 0004.0001.0001.0007 This attribute defines the timestamp of the most recent chassis power accumulator reset. |
| 1.3.6.1.4.1.674.10892.2.4.1.1.8 | ColumndrsWattsPeakUsage | read-only | mandatory | 0004.0001.0001.0008 This attribute defines the chassis peak power usage (in Watts) since last reset. |
| 1.3.6.1.4.1.674.10892.2.4.1.1.9 | ColumndrsWattsPeakTime | read-only | mandatory | 0004.0001.0001.0009 This attribute defines the timestamp of the most recent chassis peak power usage. |
| 1.3.6.1.4.1.674.10892.2.4.1.1.10 | ColumndrsWattsMinUsage | read-only | mandatory | 0004.0001.0001.0010 This attribute defines the chassis mimimum power usage (in Watts) since last reset. |
| 1.3.6.1.4.1.674.10892.2.4.1.1.11 | ColumndrsWattsMinTime | read-only | mandatory | 0004.0001.0001.0011 This attribute defines the timestamp of the most recent chassis minimum power usage. |
| 1.3.6.1.4.1.674.10892.2.4.1.1.12 | ColumndrsWattsResetTime | read-only | mandatory | 0004.0001.0001.0012 This attribute defines the timestamp of the most recent reset of the chassis min/peak Watts readings. |
| 1.3.6.1.4.1.674.10892.2.4.1.1.13 | ColumndrsWattsReading | read-only | mandatory | 0004.0001.0001.0013 This attribute defines the instantaneous chassis power usage (in Watts). |
| 1.3.6.1.4.1.674.10892.2.4.1.1.14 | ColumndrsAmpsReading | read-only | mandatory | 0004.0001.0001.0014 This attribute defines the instantaneous chassis current usage (in Watts). |
| 1.3.6.1.4.1.674.10892.2.4.2 | TabledrsCMCPSUTable | not-accessible | mandatory | 0004.0002 This object defines the CMC PSU table. |
| 1.3.6.1.4.1.674.10892.2.4.2.1 | RowdrsCMCPSUTableEntry | not-accessible | mandatory | 0004.0002.0001 This object defines the CMC PSU table entry. |
| 1.3.6.1.4.1.674.10892.2.4.2.1.1 | ColumndrsPSUChassisIndex | read-only | mandatory | 0004.0002.0001.0001 This attribute defines the index (one-based) of the associated chassis. |
| 1.3.6.1.4.1.674.10892.2.4.2.1.2 | ColumndrsPSUIndex | read-only | mandatory | 0004.0002.0001.0002 This attribute defines the index (one-based) of the associated CMC PSU. |
| 1.3.6.1.4.1.674.10892.2.4.2.1.3 | ColumndrsPSULocation | read-only | mandatory | 0004.0002.0001.0003 This attribute defines the location of the CMC PSU. |
| 1.3.6.1.4.1.674.10892.2.4.2.1.4 | ColumndrsPSUMonitoringCapable | read-only | mandatory | 0004.0002.0001.0004 This attribute defines the PSU Monitoring capabilities, or the absence of a PSU in this location. |
| 1.3.6.1.4.1.674.10892.2.4.2.1.5 | ColumndrsPSUVoltsReading | read-only | mandatory | 0004.0002.0001.0005 This attribute defines the instantaneous PSU Voltage reading. |
| 1.3.6.1.4.1.674.10892.2.4.2.1.6 | ColumndrsPSUAmpsReading | read-only | mandatory | 0004.0002.0001.0006 This attribute defines the instantaneous PSU Current reading. |
| 1.3.6.1.4.1.674.10892.2.4.2.1.7 | ColumndrsPSUWattsReading | read-only | mandatory | 0004.0002.0001.0007 This attribute defines the instantaneous PSU Wattage reading. |
| 1.3.6.1.4.1.674.10892.2.5 | NodedrsChassisServerGroup | |||
| 1.3.6.1.4.1.674.10892.2.5.1 | TabledrsCMCServerTable | not-accessible | mandatory | 0005.0001 This object defines the CMC server table. |
| 1.3.6.1.4.1.674.10892.2.5.1.1 | RowdrsCMCServerTableEntry | not-accessible | mandatory | 0005.0001.0001 This object defines the CMC server table entry. |
| 1.3.6.1.4.1.674.10892.2.5.1.1.1 | ColumndrsServerIndex | read-only | mandatory | 0005.0001.0001.0001 This attribute defines the index (one-based) of the associated CMC server. |
| 1.3.6.1.4.1.674.10892.2.5.1.1.2 | ColumndrsServerMonitoringCapable | read-only | mandatory | 0005.0001.0001.0002 This attribute defines the server monitoring capabilities, or the absence of a server in this location. |
| 1.3.6.1.4.1.674.10892.2.5.1.1.3 | ColumndrsServerServiceTag | read-only | mandatory | 0005.0001.0001.0003 This attribute defines the Service Tag of the CMC server. |
| 1.3.6.1.4.1.674.10892.2.5.1.1.4 | ColumndrsServerSlotName | read-only | mandatory | 0005.0001.0001.0004 This attribute defines the Slot Name of the CMC server. |
| 1.3.6.1.4.1.674.10892.2.5.1.1.5 | ColumndrsServerSlotNumber | read-only | mandatory | 0005.0001.0001.0005 This attribute defines the Chassis Slot Number of the CMC server. |
| 1.3.6.1.4.1.674.10892.2.5.1.1.6 | ColumndrsServerNodeID | read-only | mandatory | 0005.0001.0001.0006 This attribute defines the Node ID of the CMC server. The Node ID provides a unique identifier for the server. |
| 1.3.6.1.4.1.674.10892.2.5.1.1.7 | ColumndrsServerModel | read-only | mandatory | 0005.0001.0001.0007 This attribute defines the Model of the CMC server. |
| 1.3.6.1.4.1.674.10892.2.5.1.1.8 | ColumndrsServerAssetTag | read-only | mandatory | 0005.0001.0001.0008 This attribute defines the Asset Tag of the CMC server. |
| 1.3.6.1.4.1.674.10892.2.5.1.1.9 | ColumndrsServerNumStorageControllers | read-only | mandatory | 0005.0001.0001.0009 This attribute defines the number of storage controllers on the storage sled. The value will be zero if this is not a storage sled. |
| 1.3.6.1.4.1.674.10892.2.5.1.1.10 | ColumndrsServerStorageMode | read-only | mandatory | 0005.0001.0001.0010 This attribute defines the Storage Mode of the storage sled. |
| 1.3.6.1.4.1.674.10892.2.5.1.1.11 | ColumndrsServerIntrusionState | read-only | mandatory | 0005.0001.0001.0011 This attribute defines the Intrusion State of the CMC server if supported by the server. |
| 1.3.6.1.4.1.674.10892.2.5.1.1.12 | ColumndrsServerAssignedServerSlots | read-only | mandatory | 0005.0001.0001.0012 This attribute defines the the server slots to which a storage sled is assigned. If this is a storage sled that is assigned to one more or … |
| 1.3.6.1.4.1.674.10892.2.6 | NodestorageDetailsGroup | |||
| 1.3.6.1.4.1.674.10892.2.6.1 | Nodesoftware | |||
| 1.3.6.1.4.1.674.10892.2.6.1.20 | NodestorageManagement | |||
| 1.3.6.1.4.1.674.10892.2.6.1.20.130 | NodephysicalDevices | |||
| 1.3.6.1.4.1.674.10892.2.6.1.20.130.1 | TablecontrollerTable | not-accessible | mandatory | A table of managed RAID controllers. The number of entries is related to number of RAID controllers discovered in the system. The maximum number of entries is … |
| 1.3.6.1.4.1.674.10892.2.6.1.20.130.1.1 | RowcontrollerTableEntry | not-accessible | mandatory | An entry in the table of RAID controllers. A row in this table cannot be created or deleted by SNMP operations on columns of the table. |
| 1.3.6.1.4.1.674.10892.2.6.1.20.130.1.1.1 | ColumncontrollerNumber | read-only | mandatory | Instance number of this controller entry. |
| 1.3.6.1.4.1.674.10892.2.6.1.20.130.1.1.2 | ColumncontrollerName | read-only | mandatory | The controller's name as represented in Storage Management. |
| 1.3.6.1.4.1.674.10892.2.6.1.20.130.1.1.7 | ColumncontrollerRebuildRate | read-only | mandatory | The rebuild rate is the percentage of the controller's resources dedicated to rebuilding a failed disk when a rebuild is necessary. |
| 1.3.6.1.4.1.674.10892.2.6.1.20.130.1.1.8 | ColumncontrollerFWVersion | read-only | mandatory | The controller's current firmware version. |
| 1.3.6.1.4.1.674.10892.2.6.1.20.130.1.1.9 | ColumncontrollerCacheSizeInMB | read-only | mandatory | The controller's current amount of cache memory in megabytes. |
| 1.3.6.1.4.1.674.10892.2.6.1.20.130.1.1.37 | ColumncontrollerRollUpStatus | read-only | mandatory | Severity of the controller state. This is the combined status of the controller and its components. Possible values: 1: Other. 2: Unknown. 3: OK 4: Non-critica… |
| 1.3.6.1.4.1.674.10892.2.6.1.20.130.1.1.38 | ColumncontrollerComponentStatus | read-only | mandatory | The status of the controller itself without the propagation of any contained component status. Possible values: 1: Other 2: Unknown 3: OK 4: Non-critical 5: Cr… |
| 1.3.6.1.4.1.674.10892.2.6.1.20.130.1.1.41 | ColumncontrollerDriverVersion | read-only | mandatory | Currently installed driver version for this controller on the host. |
| 1.3.6.1.4.1.674.10892.2.6.1.20.130.1.1.42 | ColumncontrollerPCISlot | read-only | mandatory | The PCI slot on the server where the controller is seated. This data is not reported for embedded or integrated controllers, |
| 1.3.6.1.4.1.674.10892.2.6.1.20.130.1.1.48 | ColumncontrollerReconstructRate | read-only | mandatory | The reconstruct rate is the percentage of the controller's resources dedicated to reconstructing a disk group after adding a physical disk or changing the RAID… |
| 1.3.6.1.4.1.674.10892.2.6.1.20.130.1.1.49 | ColumncontrollerPatrolReadRate | read-only | mandatory | The patrol read rate is the percentage of the controller's resources dedicated to perform a patrol read on disks participating in a virtual disk or hot spares. |
| 1.3.6.1.4.1.674.10892.2.6.1.20.130.1.1.50 | ColumncontrollerBGIRate | read-only | mandatory | The background initialization (BGI) rate is the percentage of the controller's resources dedicated to performing the background initialization of a redundant v… |
| 1.3.6.1.4.1.674.10892.2.6.1.20.130.1.1.51 | ColumncontrollerCheckConsistencyRate | read-only | mandatory | The check consistency rate is the percentage of the controller's resources dedicated to performing a check consistency on a redundant virtual disk. |
| 1.3.6.1.4.1.674.10892.2.6.1.20.130.1.1.52 | ColumncontrollerPatrolReadMode | read-only | mandatory | Identifies the patrol read mode setting for the controller. Possible values: 1: Not one of the following or could not be determined. 2: Not Supported on this c… |
| 1.3.6.1.4.1.674.10892.2.6.1.20.130.1.1.53 | ColumncontrollerPatrolReadState | read-only | mandatory | This property displays the current state of the patrol read process. Possible values: 1: Not one of the following or could not be determined. 2: Patrol read is… |
| 1.3.6.1.4.1.674.10892.2.6.1.20.130.1.1.59 | ColumncontrollerPersistentHotSpare | read-only | mandatory | Indicates whether hot spare drives would be restored on insertion into the same slot. |
| 1.3.6.1.4.1.674.10892.2.6.1.20.130.1.1.60 | ColumncontrollerSpinDownUnconfiguredDrives | read-only | mandatory | Indicates whether un-configured drives would be put in power save mode by the controller. |
| 1.3.6.1.4.1.674.10892.2.6.1.20.130.1.1.61 | ColumncontrollerSpinDownHotSpareDrives | read-only | mandatory | Indicates whether hot spare drives would be put in power save mode by the controller. |
| 1.3.6.1.4.1.674.10892.2.6.1.20.130.1.1.62 | ColumncontrollerSpinDownTimeInterval | read-only | mandatory | The duration in minutes after which, the unconfigured or hot spare drives will be spun down to power save mode. |
| 1.3.6.1.4.1.674.10892.2.6.1.20.130.1.1.69 | ColumncontrollerPreservedCache | read-only | mandatory | Indicates whether preserved cache or pinned cache is present on the controller. |
| 1.3.6.1.4.1.674.10892.2.6.1.20.130.1.1.70 | ColumncontrollerCheckConsistencyMode | read-only | mandatory | The current check consistency mode setting for the controller. Possible values: 1: Not one of the following. 2: Not supported on this controller. 3: Normal che… |
| 1.3.6.1.4.1.674.10892.2.6.1.20.130.1.1.71 | ColumncontrollerCopyBackMode | read-only | mandatory | The current copy back mode setting for the controller. Possible values: 1: Not one of the following. 2: Not supported on this controller. 3: Disks assigned as … |
| 1.3.6.1.4.1.674.10892.2.6.1.20.130.1.1.72 | ColumncontrollerSecurityStatus | read-only | mandatory | The controller's current security/encryption status.. Possible values: 1: The current status could not be determined. 2: Controller is not operating in an encr… |
| 1.3.6.1.4.1.674.10892.2.6.1.20.130.1.1.73 | ColumncontrollerEncryptionKeyPresent | read-only | mandatory | Indicates whether encryption key is assigned for the controller. |
| 1.3.6.1.4.1.674.10892.2.6.1.20.130.1.1.74 | ColumncontrollerEncryptionCapability | read-only | mandatory | The type of encryption supported by the controller. Possible values: 1: Not one of the following. 2: No encryption supported, 3: Local Key Management, |
| 1.3.6.1.4.1.674.10892.2.6.1.20.130.1.1.75 | ColumncontrollerLoadBalanceSetting | read-only | mandatory | The ability of the controller to automatically use both controller ports (or connectors) connected to the same enclosure in order to route I/O requests. Possib… |
| 1.3.6.1.4.1.674.10892.2.6.1.20.130.1.1.76 | ColumncontrollerMaxCapSpeed | read-only | mandatory | The maximum speed of the controller.in Gigbits per second (Gbps). Possible values: 1: The speed could not be determined. 2. 1.5 Gbps 3: 3.0 Gbps 4: 6.0 Gbps 5:… |
| 1.3.6.1.4.1.674.10892.2.6.1.20.130.1.1.77 | ColumncontrollerSASAddress | read-only | mandatory | The SAS address of the controller. |
| 1.3.6.1.4.1.674.10892.2.6.1.20.130.1.1.78 | ColumncontrollerFQDD | read-only | mandatory | The controller's Fully Qualified Device Descriptor (FQDD) as represented in Storage Management. |
| 1.3.6.1.4.1.674.10892.2.6.1.20.130.1.1.79 | ColumncontrollerDisplayName | read-only | mandatory | The controller's friendly FQDD as represented in Storage Management. |
| 1.3.6.1.4.1.674.10892.2.6.1.20.130.1.1.80 | ColumncontrollerT10PICapability | read-only | mandatory | Indicates whether the controller supports the T10 PI (Protection Information). These protection fields are known as DIF (Data Integrity Fields). Possible value… |
| 1.3.6.1.4.1.674.10892.2.6.1.20.130.1.1.81 | ColumncontrollerRAID10UnevenSpansSupported | read-only | mandatory | Indicates whether uneven spans for RAID 10 virtual disk is supported on the controller. |
| 1.3.6.1.4.1.674.10892.2.6.1.20.130.1.1.82 | ColumncontrollerEnhancedAutoImportForeignConfigMode | read-only | mandatory | Indicates the status of enhanced auto-import of foreign configuration property of the controller. 1: Not one of the following. 2: Not Supported. 3: Disabled. 4… |
| 1.3.6.1.4.1.674.10892.2.6.1.20.130.1.1.83 | ColumncontrollerBootModeSupported | read-only | mandatory | Indicates whether headless boot mode settings are supported on the controller. |
| 1.3.6.1.4.1.674.10892.2.6.1.20.130.1.1.84 | ColumncontrollerBootMode | read-only | mandatory | Indicates the boot mode of the controller. Possible values: 1: Not applicable for this controller. 2: User mode: User interaction required for all boot message… |
| 1.3.6.1.4.1.674.10892.2.6.1.20.130.1.1.85 | ColumncontrollerHighAvailabilityMode | read-only | mandatory | Indicates the fault-tolerant mode of the controller. Possible values: 1: None 2: Fault Tolerant(Active/Passive) 3: Fault Tolerant(Active/Active) 4: Degraded |
| 1.3.6.1.4.1.674.10892.2.6.1.20.130.1.1.86 | ColumncontrollerPeerController | read-only | mandatory | The peer controller's Fully Qualified Device Descriptor (FQDD) as represented in Storage Management. |
| 1.3.6.1.4.1.674.10892.2.6.1.20.130.1.1.87 | ColumncontrollerEncryptionKeyIdentifier | read-only | mandatory | Displays the encryption security key identifier of the controller, if the controller is encryption enabled and a security key is configured for the controller. |
| 1.3.6.1.4.1.674.10892.2.6.1.20.130.3 | TableenclosureTable | not-accessible | mandatory | A table of managed enclosures/backplanes. The number of entries is related to number of internal backplane(s) discovered in the system and external storage enc… |
| 1.3.6.1.4.1.674.10892.2.6.1.20.130.3.1 | RowenclosureTableEntry | not-accessible | mandatory | An entry in the enclosure table. A row in this table cannot be created or deleted by SNMP operations on columns of the table. |
| 1.3.6.1.4.1.674.10892.2.6.1.20.130.3.1.1 | ColumnenclosureNumber | read-only | mandatory | Instance number of this enclossre/backplane. |
| 1.3.6.1.4.1.674.10892.2.6.1.20.130.3.1.2 | ColumnenclosureName | read-only | mandatory | The enclosure/backplane's name as represented in Storage Management. |
| 1.3.6.1.4.1.674.10892.2.6.1.20.130.3.1.4 | ColumnenclosureState | read-only | mandatory | The current state of this enclosure/backplane. Possible states: 1: The current state could not be determined. 2: The enclosure is operating normally. 3: The en… |
| 1.3.6.1.4.1.674.10892.2.6.1.20.130.3.1.8 | ColumnenclosureServiceTag | read-only | mandatory | Enclosure identification used when consulting customer support. |
| 1.3.6.1.4.1.674.10892.2.6.1.20.130.3.1.9 | ColumnenclosureAssetTag | read-only | mandatory | The asset tag information for the enclosure. |
| 1.3.6.1.4.1.674.10892.2.6.1.20.130.3.1.19 | ColumnenclosureConnectedPort | read-only | mandatory | The port on the controller to which the storage enclosure is connected. |
| 1.3.6.1.4.1.674.10892.2.6.1.20.130.3.1.23 | ColumnenclosureRollUpStatus | read-only | mandatory | Severity of the enclosure/backplane state. This is the combined status of the enclosure and its sub-components. Possible values: 1: Other. 2: Unknown. 3: OK. 4… |
| 1.3.6.1.4.1.674.10892.2.6.1.20.130.3.1.24 | ColumnenclosureComponentStatus | read-only | mandatory | The status of the enclosure/backplane.itself without the propagation of any contained component status. Possible values: 1: Other. 2: Unknown. 3: OK. 4: Non-cr… |
| 1.3.6.1.4.1.674.10892.2.6.1.20.130.3.1.26 | ColumnenclosureFirmwareVersion | read-only | mandatory | The firmware information for the enclosure/backplane. |
| 1.3.6.1.4.1.674.10892.2.6.1.20.130.3.1.30 | ColumnenclosureSASAddress | read-only | mandatory | The SAS address of the enclosure/backplane. |
| 1.3.6.1.4.1.674.10892.2.6.1.20.130.3.1.31 | ColumnenclosureDriveCount | read-only | mandatory | The number of disks present in the enclosure/backplane. |
| 1.3.6.1.4.1.674.10892.2.6.1.20.130.3.1.32 | ColumnenclosureTotalSlots | read-only | mandatory | The total physical drive slots in a storage enclosure or server backplane. |
| 1.3.6.1.4.1.674.10892.2.6.1.20.130.3.1.40 | ColumnenclosureFanCount | read-only | mandatory | The number of fans present in the storage enclosure. |
| 1.3.6.1.4.1.674.10892.2.6.1.20.130.3.1.41 | ColumnenclosurePSUCount | read-only | mandatory | The number of Power Supply Units (PSU) present in the storage enclosure. |
| 1.3.6.1.4.1.674.10892.2.6.1.20.130.3.1.42 | ColumnenclosureEMMCount | read-only | mandatory | The number of Enclosure Management Modules (EMM) present in the storage enclosure. |
| 1.3.6.1.4.1.674.10892.2.6.1.20.130.3.1.43 | ColumnenclosureTempProbeCount | read-only | mandatory | The number of temperature sensing devices present in the storage enclosure. |
| 1.3.6.1.4.1.674.10892.2.6.1.20.130.3.1.44 | ColumnenclosureRedundantPath | read-only | mandatory | Indicates whether the controller has multiply paths to reach the storage enclosure. |
| 1.3.6.1.4.1.674.10892.2.6.1.20.130.3.1.45 | ColumnenclosurePosition | read-only | mandatory | The possition of the storage enclosure within a daisy chain. |
| 1.3.6.1.4.1.674.10892.2.6.1.20.130.3.1.46 | ColumnenclosureBackplaneBayID | read-only | mandatory | The unique bay ID of the backplane. |
| 1.3.6.1.4.1.674.10892.2.6.1.20.130.3.1.47 | ColumnenclosureFQDD | read-only | mandatory | The enclosure/backplane's Fully Qualified Device Descriptor (FQDD) as represented in Storage Management. |
| 1.3.6.1.4.1.674.10892.2.6.1.20.130.3.1.48 | ColumnenclosureDisplayName | read-only | mandatory | The enclosure/backplane's friendly FQDD as represented in Storage Management. |
| 1.3.6.1.4.1.674.10892.2.6.1.20.130.3.1.49 | ColumnenclosureType | read-only | mandatory | The protocol supported by the backplane. Possible states: 1: Not one of the following or could not be determined. 2: Not applicable (i.e. object is not a backp… |
| 1.3.6.1.4.1.674.10892.2.6.1.20.130.4 | TablephysicalDiskTable | not-accessible | mandatory | A table of managed physical disks. The number of entries is related to number of physical Disks discovered in the system. The maximum number of entries is impl… |
| 1.3.6.1.4.1.674.10892.2.6.1.20.130.4.1 | RowphysicalDiskTableEntry | not-accessible | mandatory | An entry in the physical Disk table. A row in this table cannot be created or deleted by SNMP operations on columns of the table. |
| 1.3.6.1.4.1.674.10892.2.6.1.20.130.4.1.1 | ColumnphysicalDiskNumber | read-only | mandatory | Instance number of this physical disk entry. |
| 1.3.6.1.4.1.674.10892.2.6.1.20.130.4.1.2 | ColumnphysicalDiskName | read-only | mandatory | The physical disk's name as represented in Storage Management. |
| 1.3.6.1.4.1.674.10892.2.6.1.20.130.4.1.3 | ColumnphysicalDiskManufacturer | read-only | mandatory | The name of the physical disk's manufacturer. |
| 1.3.6.1.4.1.674.10892.2.6.1.20.130.4.1.4 | ColumnphysicalDiskState | read-only | mandatory | The current state of this physical disk. Possible states: 1: The current state could not be determined. 2: The physical disk is available for use, but no RAID … |
| 1.3.6.1.4.1.674.10892.2.6.1.20.130.4.1.6 | ColumnphysicalDiskProductID | read-only | mandatory | The model number of the physical disk. |
| 1.3.6.1.4.1.674.10892.2.6.1.20.130.4.1.7 | ColumnphysicalDiskSerialNo | read-only | mandatory | The physical disk's unique identification number from the manufacturer. |
| 1.3.6.1.4.1.674.10892.2.6.1.20.130.4.1.8 | ColumnphysicalDiskRevision | read-only | mandatory | The firmware version of the physical disk. |
| 1.3.6.1.4.1.674.10892.2.6.1.20.130.4.1.11 | ColumnphysicalDiskCapacityInMB | read-only | mandatory | The size of the physical disk in megabytes. |
| 1.3.6.1.4.1.674.10892.2.6.1.20.130.4.1.17 | ColumnphysicalDiskUsedSpaceInMB | read-only | mandatory | The amount of used space in megabytes on the physical disk. This is not applicable for NVMe devices. |
| 1.3.6.1.4.1.674.10892.2.6.1.20.130.4.1.19 | ColumnphysicalDiskFreeSpaceInMB | read-only | mandatory | The amount of free space in megabytes on the physical disk. This is not applicable for NVMe devices. |
| 1.3.6.1.4.1.674.10892.2.6.1.20.130.4.1.21 | ColumnphysicalDiskBusType | read-only | mandatory | The bus type of the physical disk. Possible values: 1: The bus type could not be determined. 2: Small Computer System Interface (SCSI). 3: Serial Attached SCSI… |
| 1.3.6.1.4.1.674.10892.2.6.1.20.130.4.1.22 | ColumnphysicalDiskSpareState | read-only | mandatory | The status of the disk as a spare. Possible values: 1: Physical disk is not a spare. 2: Physical disk is a dedicated hot spare. 3: Physical disk is a global ho… |
| 1.3.6.1.4.1.674.10892.2.6.1.20.130.4.1.24 | ColumnphysicalDiskComponentStatus | read-only | mandatory | The status of the physical disk itself without the propagation of any contained component status. Possible values: 1: Other 2: Unknown 3: OK 4: Non-critical 5:… |
| 1.3.6.1.4.1.674.10892.2.6.1.20.130.4.1.27 | ColumnphysicalDiskPartNumber | read-only | mandatory | The part number of the disk. |
| 1.3.6.1.4.1.674.10892.2.6.1.20.130.4.1.28 | ColumnphysicalDiskSASAddress | read-only | mandatory | The SAS address of the physical disk. |
| 1.3.6.1.4.1.674.10892.2.6.1.20.130.4.1.29 | ColumnphysicalDiskNegotiatedSpeed | read-only | mandatory | The data transfer speed that the disk negotiated while spinning up in Gigbits per second (Gbps). Possible values: 1: The speed could not be determined. 2. 1.5 … |
| 1.3.6.1.4.1.674.10892.2.6.1.20.130.4.1.30 | ColumnphysicalDiskCapableSpeed | read-only | mandatory | The maximum data transfer speed supported by the disk in Gigbits per second (Gbps). Possible values: 1: The speed could not be determined. 2. 1.5 Gbps 3: 3.0 G… |
| 1.3.6.1.4.1.674.10892.2.6.1.20.130.4.1.31 | ColumnphysicalDiskSmartAlertIndication | read-only | mandatory | Indicates whether the physical disk has received a predictive failure alert. |
| 1.3.6.1.4.1.674.10892.2.6.1.20.130.4.1.32 | ColumnphysicalDiskManufactureDay | read-only | mandatory | The day of the week (1=Sunday thru 7=Saturday) on which the physical disk was manufactured. |
| 1.3.6.1.4.1.674.10892.2.6.1.20.130.4.1.33 | ColumnphysicalDiskManufactureWeek | read-only | mandatory | The week (1 thru 53) in which the physical disk was manufactured. |
| 1.3.6.1.4.1.674.10892.2.6.1.20.130.4.1.34 | ColumnphysicalDiskManufactureYear | read-only | mandatory | The four digit year in which the physical disk was manufactured. |
| 1.3.6.1.4.1.674.10892.2.6.1.20.130.4.1.35 | ColumnphysicalDiskMediaType | read-only | mandatory | The media type of the physical disk. Possible Values: 1: The media type could not be determined. 2: Hard Disk Drive (HDD). 3: Solid State Device (SSD). |
| 1.3.6.1.4.1.674.10892.2.6.1.20.130.4.1.42 | ColumnphysicalDiskPowerState | read-only | mandatory | The power state of the physical disk. Possible Values: 1: Not one of the following. 2: The physical disk is in the spun up state. 3: The physical disk is in th… |
| 1.3.6.1.4.1.674.10892.2.6.1.20.130.4.1.49 | ColumnphysicalDiskRemainingRatedWriteEndurance | read-only | mandatory | This property is applicable to SSD media type only. This indicates the wear-out percentage of the SSD. Typically it is a value between 0 to 100. However, if th… |
| 1.3.6.1.4.1.674.10892.2.6.1.20.130.4.1.50 | ColumnphysicalDiskOperationalState | read-only | mandatory | The state of the physical disk when there are progressive operations ongoing. Possible values: 1: There is no active operation running. 2: Data from a redundan… |
| 1.3.6.1.4.1.674.10892.2.6.1.20.130.4.1.51 | ColumnphysicalDiskProgress | read-only | mandatory | The progress percentage of the operation that is being performed on the physical disk. This is applicable only if there is a progressive operations ongoing |
| 1.3.6.1.4.1.674.10892.2.6.1.20.130.4.1.52 | ColumnphysicalDiskSecurityStatus | read-only | mandatory | The security/encryption status of the physical disk. Possible Values: 1: The physical disk supports encryption. 2: The physical disk does not support encryptio… |
| 1.3.6.1.4.1.674.10892.2.6.1.20.130.4.1.53 | ColumnphysicalDiskFormFactor | read-only | mandatory | The form factor of the physical disk. Possible values: 1: The form factor could not be determined. 2: 1.8 inch. 3: 2.5 inch. 4: 3.5 inch. |
| 1.3.6.1.4.1.674.10892.2.6.1.20.130.4.1.54 | ColumnphysicalDiskFQDD | read-only | mandatory | The physical disk's Fully Qualified Device Descriptor (FQDD) as represented in Storage Management. |
| 1.3.6.1.4.1.674.10892.2.6.1.20.130.4.1.55 | ColumnphysicalDiskDisplayName | read-only | mandatory | The physical disk's friendly FQDD as represented in Storage Management. |
| 1.3.6.1.4.1.674.10892.2.6.1.20.130.4.1.57 | ColumnphysicalDiskT10PICapability | read-only | mandatory | Indicates whether the physical disk supports the T10 PI (Protection Information). These protection fields are known as DIF (Data Integrity Fields). Possible va… |
| 1.3.6.1.4.1.674.10892.2.6.1.20.130.4.1.58 | ColumnphysicalDiskBlockSizeInBytes | read-only | mandatory | The block size (in bytes) of the physical disk. This is not applicable for NVMe devices. Possible values: 1: 512. 2: 4096 |
| 1.3.6.1.4.1.674.10892.2.6.1.20.130.4.1.59 | ColumnphysicalDiskProtocolVersion | read-only | mandatory | Applicable for NVMe devices only. The NVMe protocol version supported by the device. |
| 1.3.6.1.4.1.674.10892.2.6.1.20.130.4.1.60 | ColumnphysicalDiskPCIeNegotiatedLinkWidth | read-only | mandatory | Applicable for NVMe devices only. The PCIe link width negotiated with the host during device initialization. |
| 1.3.6.1.4.1.674.10892.2.6.1.20.130.4.1.61 | ColumnphysicalDiskPCIeCapableLinkWidth | read-only | mandatory | Applicable for NVMe devices only. The PCIe link widths the device is capable of supporting. |
| 1.3.6.1.4.1.674.10892.2.6.1.20.130.4.1.62 | ColumnphysicalDiskCurrentActiveController | read-only | mandatory | Indicates the Fully Qualified Device Descriptor (FQDD) of the current active controller. |
| 1.3.6.1.4.1.674.10892.2.6.1.20.130.4.1.63 | ColumnphysicalDiskFailoverController | read-only | mandatory | Indicates the Fully Qualified Device Descriptor (FQDD) of the failover controller. |
| 1.3.6.1.4.1.674.10892.2.6.1.20.130.4.1.64 | ColumnphysicalDiskForeignKeyIdentifier | read-only | mandatory | Displays the encryption key identifier of the physical disk if it is in locked or foreign state. |
| 1.3.6.1.4.1.674.10892.2.6.1.20.130.7 | TableenclosureFanTable | not-accessible | mandatory | A table of managed fans in the external storage enclosure(s). The number of entries is related to number of fans discovered in the enclosure(s). The maximum nu… |
| 1.3.6.1.4.1.674.10892.2.6.1.20.130.7.1 | RowenclosureFanTableEntry | not-accessible | mandatory | An entry in the fan table. A row in this table cannot be created or deleted by SNMP operations on columns of the table. |
| 1.3.6.1.4.1.674.10892.2.6.1.20.130.7.1.1 | ColumnenclosureFanNumber | read-only | mandatory | Instance number of this fan. |
| 1.3.6.1.4.1.674.10892.2.6.1.20.130.7.1.2 | ColumnenclosureFanName | read-only | mandatory | The fan's name as represented in Storage Management. |
| 1.3.6.1.4.1.674.10892.2.6.1.20.130.7.1.4 | ColumnenclosureFanState | read-only | mandatory | The current state of this fan. Possible states: 1: The current state could not be determined. 2: The fan is operating normally. 3: The fan has encountered a ha… |
| 1.3.6.1.4.1.674.10892.2.6.1.20.130.7.1.11 | ColumnenclosureFanSpeed | read-only | mandatory | Indicates the current relative speed of the fan in RPMs. |
| 1.3.6.1.4.1.674.10892.2.6.1.20.130.7.1.15 | ColumnenclosureFanComponentStatus | read-only | mandatory | The status of the fan itself without the propagation of any contained component status. Possible values: 1: Other. 2: Unknown. 3: OK. 4: Non-critical . 5: Crit… |
| 1.3.6.1.4.1.674.10892.2.6.1.20.130.7.1.20 | ColumnenclosureFanFQDD | read-only | mandatory | The fan's Fully Qualified Device Descriptor (FQDD) as represented in Storage Management. |
| 1.3.6.1.4.1.674.10892.2.6.1.20.130.7.1.21 | ColumnenclosureFanDisplayName | read-only | mandatory | The fan's friendly FQDD as represented in Storage Management. |
| 1.3.6.1.4.1.674.10892.2.6.1.20.130.9 | TableenclosurePowerSupplyTable | not-accessible | mandatory | A table of managed Power Supply Units(PSU) in the external storage enclosure(s). The number of entries is related to number of power supply unit(s) discovered … |
| 1.3.6.1.4.1.674.10892.2.6.1.20.130.9.1 | RowenclosurePowerSupplyTableEntry | not-accessible | mandatory | An entry in the power supply unit table. A row in this table cannot be created or deleted by SNMP operations on columns of the table. |
| 1.3.6.1.4.1.674.10892.2.6.1.20.130.9.1.1 | ColumnenclosurePowerSupplyNumber | read-only | mandatory | Instance number of this power supply unit. |
| 1.3.6.1.4.1.674.10892.2.6.1.20.130.9.1.2 | ColumnenclosurePowerSupplyName | read-only | mandatory | The power supply unit's name as represented in Storage Management. |
| 1.3.6.1.4.1.674.10892.2.6.1.20.130.9.1.4 | ColumnenclosurePowerSupplyState | read-only | mandatory | The current state of this power supply unit. Possible states: 1: The current state could not be determined. 2: The power supply unit is operating normally. 3: … |
| 1.3.6.1.4.1.674.10892.2.6.1.20.130.9.1.7 | ColumnenclosurePowerSupplyPartNumber | read-only | mandatory | The part number of the power supply unit. |
| 1.3.6.1.4.1.674.10892.2.6.1.20.130.9.1.9 | ColumnenclosurePowerSupplyComponentStatus | read-only | mandatory | The status of the power supply unit itself without the propagation of any contained component status. Possible values: 1: Other. 2: Unknown. 3: OK. 4: Non-crit… |
| 1.3.6.1.4.1.674.10892.2.6.1.20.130.9.1.15 | ColumnenclosurePowerSupplyFQDD | read-only | mandatory | The power supply unit's Fully Qualified Device Descriptor (FQDD) as represented in Storage Management. |
| 1.3.6.1.4.1.674.10892.2.6.1.20.130.9.1.16 | ColumnenclosurePowerSupplyDisplayName | read-only | mandatory | The power supply unit's friendly FQDD as represented in Storage Management. |
| 1.3.6.1.4.1.674.10892.2.6.1.20.130.11 | TableenclosureTemperatureProbeTable | not-accessible | mandatory | A table of managed temperature probes in the external storage enclosure(s). The number of entries is related to number of temperature probes discovered in the … |
| 1.3.6.1.4.1.674.10892.2.6.1.20.130.11.1 | RowenclosureTemperatureProbeTableEntry | not-accessible | mandatory | An entry in the temperature probe table. A row in this table cannot be created or deleted by SNMP operations on columns of the table. |
| 1.3.6.1.4.1.674.10892.2.6.1.20.130.11.1.1 | ColumnenclosureTemperatureProbeNumber | read-only | mandatory | Instance number of this temperature probe. |
| 1.3.6.1.4.1.674.10892.2.6.1.20.130.11.1.2 | ColumnenclosureTemperatureProbeName | read-only | mandatory | The temperature probe's name as represented in Storage Management. |
| 1.3.6.1.4.1.674.10892.2.6.1.20.130.11.1.4 | ColumnenclosureTemperatureProbeState | read-only | mandatory | The current state of this temperature probe. Possible states: 1: The current state could not be determined. 2: The temperature probe is operating normally. 3: … |
| 1.3.6.1.4.1.674.10892.2.6.1.20.130.11.1.7 | ColumnenclosureTemperatureProbeMinWarningValue | read-only | mandatory | The minimum temperature that will force the probe into a warning state. |
| 1.3.6.1.4.1.674.10892.2.6.1.20.130.11.1.8 | ColumnenclosureTemperatureProbeMinCriticalValue | read-only | mandatory | The minimum temperature that will force the probe into a error state. |
| 1.3.6.1.4.1.674.10892.2.6.1.20.130.11.1.9 | ColumnenclosureTemperatureProbeMaxWarningValue | read-only | mandatory | The maximum temperature that will force the probe into a warning state. |
| 1.3.6.1.4.1.674.10892.2.6.1.20.130.11.1.10 | ColumnenclosureTemperatureProbeMaxCriticalValue | read-only | mandatory | The maximum temperature that will force the probe into a warning state. |
| 1.3.6.1.4.1.674.10892.2.6.1.20.130.11.1.11 | ColumnenclosureTemperatureProbeCurValue | read-only | mandatory | The maximum temperature that will force the probe into a warning state. |
| 1.3.6.1.4.1.674.10892.2.6.1.20.130.11.1.13 | ColumnenclosureTemperatureProbeComponentStatus | read-only | mandatory | The status of the enclosure management module.itself without the propagation of any contained component status. Possible values: 1: Other. 2: Unknown. 3: OK. 4… |
| 1.3.6.1.4.1.674.10892.2.6.1.20.130.11.1.15 | ColumnenclosureTemperatureProbeFQDD | read-only | mandatory | The temperature probe's Fully Qualified Device Descriptor (FQDD) as represented in Storage Management. |
| 1.3.6.1.4.1.674.10892.2.6.1.20.130.11.1.16 | ColumnenclosureTemperatureProbeDisplayName | read-only | mandatory | The temperature probe's friendly FQDD as represented in Storage Management. |
| 1.3.6.1.4.1.674.10892.2.6.1.20.130.13 | TableenclosureManagementModuleTable | not-accessible | mandatory | A table of managed Enclosure Management Modules (EMM) in the external storage enclosure(s). The number of entries is related to number of enclosure management … |
| 1.3.6.1.4.1.674.10892.2.6.1.20.130.13.1 | RowenclosureManagementModuleTableEntry | not-accessible | mandatory | An entry in the enclosure management module table. A row in this table cannot be created or deleted by SNMP operations on columns of the table. |
| 1.3.6.1.4.1.674.10892.2.6.1.20.130.13.1.1 | ColumnenclosureManagementModuleNumber | read-only | mandatory | Instance number of this enclosure management module. |
| 1.3.6.1.4.1.674.10892.2.6.1.20.130.13.1.2 | ColumnenclosureManagementModuleName | read-only | mandatory | The enclosure management module's name as represented in Storage Management. |
| 1.3.6.1.4.1.674.10892.2.6.1.20.130.13.1.4 | ColumnenclosureManagementModuleState | read-only | mandatory | The current state of this enclosure management module. Possible states: 1: The current state could not be determined. 2: The enclosure management module is ope… |
| 1.3.6.1.4.1.674.10892.2.6.1.20.130.13.1.6 | ColumnenclosureManagementModulePartNumber | read-only | mandatory | The part number of the enclosure management module. |
| 1.3.6.1.4.1.674.10892.2.6.1.20.130.13.1.8 | ColumnenclosureManagementModuleFWVersion | read-only | mandatory | Firmware version of the enclosure management module. |
| 1.3.6.1.4.1.674.10892.2.6.1.20.130.13.1.11 | ColumnenclosureManagementModuleComponentStatus | read-only | mandatory | The status of the enclosure management module.itself without the propagation of any contained component status. Possible values: 1: Other. 2: Unknown. 3: OK. 4… |
| 1.3.6.1.4.1.674.10892.2.6.1.20.130.13.1.15 | ColumnenclosureManagementModuleFQDD | read-only | mandatory | The enclosure management module's Fully Qualified Device Descriptor (FQDD) as represented in Storage Management. |
| 1.3.6.1.4.1.674.10892.2.6.1.20.130.13.1.16 | ColumnenclosureManagementModuleDisplayName | read-only | mandatory | The enclosure management module's friendly FQDD as represented in Storage Management. |
| 1.3.6.1.4.1.674.10892.2.6.1.20.130.15 | TablebatteryTable | not-accessible | mandatory | A table of managed batteries. The number of entries is related to number of Batteries discovered in the system. The maximum number of entries is implementation… |
| 1.3.6.1.4.1.674.10892.2.6.1.20.130.15.1 | RowbatteryTableEntry | not-accessible | mandatory | An entry in the battery table. A row in this table cannot be created or deleted by SNMP operations on columns of the table. |
| 1.3.6.1.4.1.674.10892.2.6.1.20.130.15.1.1 | ColumnbatteryNumber | read-only | mandatory | Instance number of this battery entry. |
| 1.3.6.1.4.1.674.10892.2.6.1.20.130.15.1.4 | ColumnbatteryState | read-only | mandatory | Current state of battery. Possible values: 1: The current state could not be determined. 2: The battery is operating normally. 3: The battery has failed and ne… |
| 1.3.6.1.4.1.674.10892.2.6.1.20.130.15.1.6 | ColumnbatteryComponentStatus | read-only | mandatory | The status of the battery itself without the propagation of any contained component status. Possible values: 1: Other 2: Unknown 3: OK 4: Non-critical 5: Criti… |
| 1.3.6.1.4.1.674.10892.2.6.1.20.130.15.1.10 | ColumnbatteryPredictedCapacity | read-only | obsolete | This entry is obsolete. Use the batteryComponentStatus or batteryState instead. |
| 1.3.6.1.4.1.674.10892.2.6.1.20.130.15.1.20 | ColumnbatteryFQDD | read-only | mandatory | The battery's Fully Qualified Device Descriptor (FQDD) as represented in Storage Management. |
| 1.3.6.1.4.1.674.10892.2.6.1.20.130.15.1.21 | ColumnbatteryDisplayName | read-only | mandatory | The battery's friendly FQDD as represented in Storage Management. |
| 1.3.6.1.4.1.674.10892.2.6.1.20.140 | NodelogicalDevices | |||
| 1.3.6.1.4.1.674.10892.2.6.1.20.140.1 | TablevirtualDiskTable | not-accessible | mandatory | A table of managed virtual disks. The number of entries is related to number of virtual disks discovered in the system. The maximum number of entries is implem… |
| 1.3.6.1.4.1.674.10892.2.6.1.20.140.1.1 | RowvirtualDiskTableEntry | not-accessible | mandatory | An entry in the virtual disk table. A row in this table cannot be created or deleted by SNMP operations on columns of the table. |
| 1.3.6.1.4.1.674.10892.2.6.1.20.140.1.1.1 | ColumnvirtualDiskNumber | read-only | mandatory | Instance number of this virtual disk entry. |
| 1.3.6.1.4.1.674.10892.2.6.1.20.140.1.1.2 | ColumnvirtualDiskName | read-only | mandatory | The virtual disk's label as entered by the user. |
| 1.3.6.1.4.1.674.10892.2.6.1.20.140.1.1.4 | ColumnvirtualDiskState | read-only | mandatory | The current state of this virtual disk (which includes any member physical disks.) Possible states: 1: The current state could not be determined. 2: The virtua… |
| 1.3.6.1.4.1.674.10892.2.6.1.20.140.1.1.6 | ColumnvirtualDiskSizeInMB | read-only | mandatory | The size of the virtual disk in megabytes. |
| 1.3.6.1.4.1.674.10892.2.6.1.20.140.1.1.10 | ColumnvirtualDiskWritePolicy | read-only | mandatory | The write policy used by the controller for write operations on this virtual disk. Possible values: 1: Write Through. 2: Write Back. 3: Force Write Back. |
| 1.3.6.1.4.1.674.10892.2.6.1.20.140.1.1.11 | ColumnvirtualDiskReadPolicy | read-only | mandatory | The read policy used by the controller for read operations on this virtual disk. Possible values: 1: No Read Ahead. 2: Read Ahead. 3: Adaptive Read Ahead. |
| 1.3.6.1.4.1.674.10892.2.6.1.20.140.1.1.13 | ColumnvirtualDiskLayout | read-only | mandatory | The virtual disk's RAID type. Possible values: 1: Not one of the following 2: RAID-0 3: RAID-1 4: RAID-5 5: RAID-6 6: RAID-10 7: RAID-50 8: RAID-60 9: Concaten… |
| 1.3.6.1.4.1.674.10892.2.6.1.20.140.1.1.14 | ColumnvirtualDiskStripeSize | read-only | mandatory | The stripe size of this virtual disk. Possible values: 1: Not one of the following 2: Default. 3: 512 bytes 4: 1 kB, 5: 2 kB, 6: 4 kB, 7: 8 kB, 8: 16 kB, 9: 32… |
| 1.3.6.1.4.1.674.10892.2.6.1.20.140.1.1.20 | ColumnvirtualDiskComponentStatus | read-only | mandatory | The status of the virtual disk itself without the propagation of any contained component status. Possible values: 1: Other. 2: Unknown. 3: OK. 4: Non-critical … |
| 1.3.6.1.4.1.674.10892.2.6.1.20.140.1.1.23 | ColumnvirtualDiskBadBlocksDetected | read-only | mandatory | Indicates whether the virtual disk has bad blocks. |
| 1.3.6.1.4.1.674.10892.2.6.1.20.140.1.1.24 | ColumnvirtualDiskSecured | read-only | mandatory | Indicates whether the virtual disk is secured or not. |
| 1.3.6.1.4.1.674.10892.2.6.1.20.140.1.1.25 | ColumnvirtualDiskIsCacheCade | read-only | mandatory | Indicates whether the virtual disk is being used as a secondary cache by the controller. |
| 1.3.6.1.4.1.674.10892.2.6.1.20.140.1.1.26 | ColumnvirtualDiskDiskCachePolicy | read-only | mandatory | The cache policy of the physical disks that are part of this virtual disk Possible values: 1: Enabled. 2: Disabled. 3: Default. |
| 1.3.6.1.4.1.674.10892.2.6.1.20.140.1.1.30 | ColumnvirtualDiskOperationalState | read-only | mandatory | The state of the virtual disk when there are progressive operations ongoing. Possible values: 1: There is no active operation running. 2: The virtual disk conf… |
| 1.3.6.1.4.1.674.10892.2.6.1.20.140.1.1.31 | ColumnvirtualDiskProgress | read-only | mandatory | The progress percentage of the operation that is being performed on the virtual disk. This is applicable only if there is a progressive operations ongoing |
| 1.3.6.1.4.1.674.10892.2.6.1.20.140.1.1.32 | ColumnvirtualDiskAvailableProtocols | read-only | mandatory | List of protocols support by physical disks part of this virtual disk. For e.g. SAS for Serial Attached SCSI or SATA for Serial Advanced Technology Attachment. |
| 1.3.6.1.4.1.674.10892.2.6.1.20.140.1.1.33 | ColumnvirtualDiskMediaType | read-only | mandatory | List of media types of the physical disks part of this virtual disk. For e.g. HDD for Hard Disk Drive or SSD for Solid State Device. |
| 1.3.6.1.4.1.674.10892.2.6.1.20.140.1.1.34 | ColumnvirtualDiskRemainingRedundancy | read-only | mandatory | The number of physical disks which can be lost before the virtual disk loses its redundancy. |
| 1.3.6.1.4.1.674.10892.2.6.1.20.140.1.1.35 | ColumnvirtualDiskFQDD | read-only | mandatory | The virtual disk's Fully Qualified Device Descriptor (FQDD) as represented in Storage Management. |
| 1.3.6.1.4.1.674.10892.2.6.1.20.140.1.1.36 | ColumnvirtualDiskDisplayName | read-only | mandatory | The virtual disk's friendly FQDD as represented in Storage Management. |
| 1.3.6.1.4.1.674.10892.2.6.1.20.140.1.1.37 | ColumnvirtualDiskT10PIStatus | read-only | mandatory | Indicates whether the virtual disk supports the T10 PI (Protection Information). These protection fields are known as DIF (Data Integrity Fields). Possible val… |
| 1.3.6.1.4.1.674.10892.2.6.1.20.140.1.1.38 | ColumnvirtualDiskBlockSizeInBytes | read-only | mandatory | The block size (in bytes) of the physical disk part of the virtual disk. Possible values: 1: 512. 2: 4096 |
| 1.3.6.1.4.1.674.10892.2.6.1.20.140.1.1.39 | ColumnvirtualDiskAdapter1AccessPolicy | read-only | mandatory | Indicates the access policy of the virtual disk with the virtual adapters. Possible values: 1: No Access. 2: Full Access |
| 1.3.6.1.4.1.674.10892.2.6.1.20.140.1.1.40 | ColumnvirtualDiskAdapter2AccessPolicy | read-only | mandatory | Indicates the access policy of the virtual disk with the virtual adapters. Possible values: 1: No Access. 2: Full Access |
| 1.3.6.1.4.1.674.10892.2.6.1.20.140.1.1.41 | ColumnvirtualDiskAdapter3AccessPolicy | read-only | mandatory | Indicates the access policy of the virtual disk with the virtual adapters. Possible values: 1: No Access. 2: Full Access |
| 1.3.6.1.4.1.674.10892.2.6.1.20.140.1.1.42 | ColumnvirtualDiskAdapter4AccessPolicy | read-only | mandatory | Indicates the access policy of the virtual disk with the virtual adapters. Possible values: 1: No Access. 2: Full Access |
| 1.3.6.1.4.1.674.10892.2.6.1.20.140.1.1.43 | ColumnvirtualDiskCurrentActiveController | read-only | mandatory | Indicates the Fully Qualified Device Descriptor (FQDD) of the current active controller. |
| 1.3.6.1.4.1.674.10892.2.6.1.20.140.1.1.44 | ColumnvirtualDiskFailoverController | read-only | mandatory | Indicates the Fully Qualified Device Descriptor (FQDD) of the failover controller. |
| 1.3.6.1.4.1.674.10892.2.20 | NodedrsCMCAlertGroup | |||
| 1.3.6.1.4.1.674.10892.2.20.10 | NodedrsChassisAlertVariables | |||
| 1.3.6.1.4.1.674.10892.2.20.10.1 | ScalardrsCASubSystem | read-only | mandatory | 0020.0010.0001 This attribute defines the Sub-System Name of the CMC Alert |
| 1.3.6.1.4.1.674.10892.2.20.10.2 | ScalardrsCASSCurrStatus | read-only | mandatory | 0020.0010.0002 This attribute defines the Current Status of the Alerting Sub-System |
| 1.3.6.1.4.1.674.10892.2.20.10.3 | ScalardrsCASSPrevStatus | read-only | mandatory | 0020.0010.0003 This attribute defines the Previous Status of the Alerting Sub-System |
| 1.3.6.1.4.1.674.10892.2.20.10.4 | ScalardrsCASSChangeTime | read-only | mandatory | 0020.0010.0004 This attribute defines the Timestamp of Most Recent Change of the Alerting Sub-System |
| 1.3.6.1.4.1.674.10892.2.20.10.5 | ScalardrsCAMessage | read-only | mandatory | 0020.0010.0005 This attribute defines the CSSD message of the CMC Alert |
| 1.3.6.1.4.1.674.10892.2.21 | NodedrsCMCAlert2Group | |||
| 1.3.6.1.4.1.674.10892.2.21.10 | NodedrsChassisAlert2Variables | |||
| 1.3.6.1.4.1.674.10892.2.21.10.1 | ScalardrsCA2MessageID | read-only | mandatory | Message ID of the alert. |
| 1.3.6.1.4.1.674.10892.2.21.10.2 | ScalardrsCA2Message | read-only | mandatory | Message describing the alert. |
| 1.3.6.1.4.1.674.10892.2.21.10.3 | ScalardrsCA2MessageArgs | read-only | mandatory | Concatenated set of strings representing any message arguments that were used to construct the alert message. Each message argument string is enclosed in doubl… |
| 1.3.6.1.4.1.674.10892.2.21.10.4 | ScalardrsCA2AlertStatus | read-only | mandatory | Status of the alert. |
| 1.3.6.1.4.1.674.10892.2.21.10.5 | ScalardrsCA2FQDD | read-only | mandatory | Fully qualified device descriptor of device causing the alert. |
| 1.3.6.1.4.1.674.10892.2.21.2153 | Nodealert2FanFailure | Fan failure. | ||
| 1.3.6.1.4.1.674.10892.2.21.2154 | Nodealert2FanWarning | Fan warning. | ||
| 1.3.6.1.4.1.674.10892.2.21.2155 | Nodealert2FanInformation | Fan information. | ||
| 1.3.6.1.4.1.674.10892.2.21.2161 | Nodealert2TemperatureProbeFailure | Temperature sensor has detected a failure value. | ||
| 1.3.6.1.4.1.674.10892.2.21.2162 | Nodealert2TemperatureProbeWarning | Temperature sensor has detected a warning value. | ||
| 1.3.6.1.4.1.674.10892.2.21.2163 | Nodealert2TemperatureProbeNormal | Temperature sensor value is within range. | ||
| 1.3.6.1.4.1.674.10892.2.21.2169 | Nodealert2VoltageProbeFailure | Voltage sensor has detected a failure value. | ||
| 1.3.6.1.4.1.674.10892.2.21.2170 | Nodealert2VoltageProbeWarning | Voltage sensor has detected a warning value. | ||
| 1.3.6.1.4.1.674.10892.2.21.2171 | Nodealert2VoltageProbeNormal | Voltage sensor reading is within range. | ||
| 1.3.6.1.4.1.674.10892.2.21.2177 | Nodealert2AmperageProbeFailure | Current sensor has detected a failure value. | ||
| 1.3.6.1.4.1.674.10892.2.21.2178 | Nodealert2AmperageProbeWarning | Current sensor has detected a warning value. | ||
| 1.3.6.1.4.1.674.10892.2.21.2179 | Nodealert2AmperageProbeNormal | Current sensor reading is within range. | ||
| 1.3.6.1.4.1.674.10892.2.21.2185 | Nodealert2PowerSupplyFailure | Power supply has detected a failure. | ||
| 1.3.6.1.4.1.674.10892.2.21.2186 | Nodealert2PowerSupplyWarning | Power supply has detected a warning. | ||
| 1.3.6.1.4.1.674.10892.2.21.2187 | Nodealert2PowerSupplyNormal | Power supply has returned to normal. | ||
| 1.3.6.1.4.1.674.10892.2.21.2225 | Nodealert2BatteryFailure | Battery has failed or battery is absent. | ||
| 1.3.6.1.4.1.674.10892.2.21.2226 | Nodealert2BatteryWarning | Battery is low. | ||
| 1.3.6.1.4.1.674.10892.2.21.2227 | Nodealert2BatteryNormal | Battery state has returned to normal; or battery presence had been detected. | ||
| 1.3.6.1.4.1.674.10892.2.21.2249 | Nodealert2LinkStatusFailure | Link status failure or critical event. | ||
| 1.3.6.1.4.1.674.10892.2.21.2250 | Nodealert2LinkStatusWarning | Link status warning. | ||
| 1.3.6.1.4.1.674.10892.2.21.2251 | Nodealert2LinkStatusInformation | Link status information. | ||
| 1.3.6.1.4.1.674.10892.2.21.2273 | Nodealert2PowerUsageFailure | Power usage failure. | ||
| 1.3.6.1.4.1.674.10892.2.21.2274 | Nodealert2PowerUsageWarning | Power usage warning. | ||
| 1.3.6.1.4.1.674.10892.2.21.2275 | Nodealert2PowerUsageInformation | Power usage information. | ||
| 1.3.6.1.4.1.674.10892.2.21.2329 | Nodealert2HardwareConfigurationFailure | Hardware configuration failure or critical event. | ||
| 1.3.6.1.4.1.674.10892.2.21.2330 | Nodealert2HardwareConfigurationWarning | Hardware configuration warning. | ||
| 1.3.6.1.4.1.674.10892.2.21.2331 | Nodealert2HardwareConfigurationInformation | Hardware configuration information. | ||
| 1.3.6.1.4.1.674.10892.2.21.2337 | Nodealert2SoftwareConfigurationFailure | Software configuration failure. | ||
| 1.3.6.1.4.1.674.10892.2.21.2338 | Nodealert2SoftwareConfigurationWarning | Software configuration warning. | ||
| 1.3.6.1.4.1.674.10892.2.21.2339 | Nodealert2SoftwareConfigurationInformation | Software configuration information. | ||
| 1.3.6.1.4.1.674.10892.2.21.2377 | Nodealert2SystemEventLogFailure | System Event Log failure or critical event. | ||
| 1.3.6.1.4.1.674.10892.2.21.2378 | Nodealert2SystemEventLogWarning | System Event Log warning. | ||
| 1.3.6.1.4.1.674.10892.2.21.2379 | Nodealert2SystemEventLogInformation | System Event Log information. | ||
| 1.3.6.1.4.1.674.10892.2.21.2385 | Nodealert2SecurityFailure | Security failure or critical event. | ||
| 1.3.6.1.4.1.674.10892.2.21.2386 | Nodealert2SecurityWarning | Security warning. | ||
| 1.3.6.1.4.1.674.10892.2.21.2387 | Nodealert2SecurityInformation | Security information. | ||
| 1.3.6.1.4.1.674.10892.2.21.2393 | Nodealert2CableFailure | Cable failure. | ||
| 1.3.6.1.4.1.674.10892.2.21.2417 | Nodealert2PCIDeviceFailure | PCI device failure or critical event. | ||
| 1.3.6.1.4.1.674.10892.2.21.2418 | Nodealert2PCIDeviceWarning | PCI device warning. | ||
| 1.3.6.1.4.1.674.10892.2.21.2419 | Nodealert2PCIDeviceInformation | PCI device information. | ||
| 1.3.6.1.4.1.674.10892.2.21.2465 | Nodealert2PowerSupplyAbsent | Power supply is absent. | ||
| 1.3.6.1.4.1.674.10892.2.21.2473 | Nodealert2RedundancyLost | Redundancy is lost. | ||
| 1.3.6.1.4.1.674.10892.2.21.2474 | Nodealert2RedundancyDegraded | Redundancy is degraded. | ||
| 1.3.6.1.4.1.674.10892.2.21.2475 | Nodealert2RedundancyInformation | Redundancy information. | ||
| 1.3.6.1.4.1.674.10892.2.21.2545 | Nodealert2CMCFailure | Chassis Management Controller detected an error. | ||
| 1.3.6.1.4.1.674.10892.2.21.2546 | Nodealert2CMCWarning | Chassis Management Controller detected a warning. | ||
| 1.3.6.1.4.1.674.10892.2.21.2553 | Nodealert2IOVirtualizationFailure | IO Virtualization failure or critical event. | ||
| 1.3.6.1.4.1.674.10892.2.21.2554 | Nodealert2IOVirtualizationWarning | IO Virtualization warning. | ||
| 1.3.6.1.4.1.674.10892.2.21.2555 | Nodealert2IOVirtualizationInformation | IO Virtualization information. | ||
| 1.3.6.1.4.1.674.10892.2.21.4177 | Nodealert2StorageManagementFailure | Storage Management has detected a device independent error condition. There is no global status change associated with this trap. | ||
| 1.3.6.1.4.1.674.10892.2.21.4178 | Nodealert2StorageManagementWarning | Storage Management has detected a device independent warning condition. There is no global status change associated with this trap. | ||
| 1.3.6.1.4.1.674.10892.2.21.4179 | Nodealert2StorageManagementInformation | Storage Management information. There is no global status change associated with this trap. | ||
| 1.3.6.1.4.1.674.10892.2.21.4201 | Nodealert2StorageFanFailure | Storage Fan failure. | ||
| 1.3.6.1.4.1.674.10892.2.21.4202 | Nodealert2StorageFanWarning | Storage Fan warning. | ||
| 1.3.6.1.4.1.674.10892.2.21.4203 | Nodealert2StorageFanInformation | Storage Fan information. | ||
| 1.3.6.1.4.1.674.10892.2.21.4209 | Nodealert2StorageTemperatureProbeFailure | Storage Temperature probe failure. | ||
| 1.3.6.1.4.1.674.10892.2.21.4210 | Nodealert2StorageTemperatureProbeWarning | Storage Temperature probe warning. | ||
| 1.3.6.1.4.1.674.10892.2.21.4211 | Nodealert2StorageTemperatureProbeInformation | Storage Temperature probe information. | ||
| 1.3.6.1.4.1.674.10892.2.21.4233 | Nodealert2StoragePowerSupplyFailure | Storage Power supply failure. | ||
| 1.3.6.1.4.1.674.10892.2.21.4234 | Nodealert2StoragePowerSupplyWarning | Storage Power supply warning. | ||
| 1.3.6.1.4.1.674.10892.2.21.4235 | Nodealert2StoragePowerSupplyInformation | Storage Power supply information. | ||
| 1.3.6.1.4.1.674.10892.2.21.4273 | Nodealert2StorageBatteryFailure | Storage Battery failure. | ||
| 1.3.6.1.4.1.674.10892.2.21.4274 | Nodealert2StorageBatteryWarning | Storage Battery warning. | ||
| 1.3.6.1.4.1.674.10892.2.21.4275 | Nodealert2StorageBatteryInformation | Storage Battery information. | ||
| 1.3.6.1.4.1.674.10892.2.21.4329 | Nodealert2StorageControllerFailure | Storage Controller failure. | ||
| 1.3.6.1.4.1.674.10892.2.21.4330 | Nodealert2StorageControllerWarning | Storage Controller warning. | ||
| 1.3.6.1.4.1.674.10892.2.21.4331 | Nodealert2StorageControllerInformation | Storage Controller information. | ||
| 1.3.6.1.4.1.674.10892.2.21.4337 | Nodealert2StorageEnclosureFailure | Storage Enclosure failure. | ||
| 1.3.6.1.4.1.674.10892.2.21.4338 | Nodealert2StorageEnclosureWarning | Storage Enclosure warning. | ||
| 1.3.6.1.4.1.674.10892.2.21.4339 | Nodealert2StorageEnclosureInformation | Storage Enclosure information. | ||
| 1.3.6.1.4.1.674.10892.2.21.4345 | Nodealert2StoragePhysicalDiskFailure | Storage Physical disk failure. | ||
| 1.3.6.1.4.1.674.10892.2.21.4346 | Nodealert2StoragePhysicalDiskWarning | Storage Physical disk warning. | ||
| 1.3.6.1.4.1.674.10892.2.21.4347 | Nodealert2StoragePhysicalDiskInformation | Storage Physical disk information. | ||
| 1.3.6.1.4.1.674.10892.2.21.4353 | Nodealert2StorageVirtualDiskFailure | Storage Virtual disk failure. | ||
| 1.3.6.1.4.1.674.10892.2.21.4354 | Nodealert2StorageVirtualDiskWarning | Storage Virtual disk warning. | ||
| 1.3.6.1.4.1.674.10892.2.21.4355 | Nodealert2StorageVirtualDiskInformation | Storage Virtual disk information. | ||
| 1.3.6.1.4.1.674.10892.2.21.4433 | Nodealert2StorageSecurityFailure | Storage Security failure or critical event. | ||
| 1.3.6.1.4.1.674.10892.2.21.4434 | Nodealert2StorageSecurityWarning | Storage Security warning. | ||
| 1.3.6.1.4.1.674.10892.2.21.4435 | Nodealert2StorageSecurityInformation | Storage Security information. | ||
| 1.3.6.1.4.1.674.10892.2.21.6314 | Nodealert2SoftwareChangeUpdateWarning | Software change update warning. | ||
| 1.3.6.1.4.1.674.10892.2.21.8305 | Nodealert2IOMTemperatureExceeded | I/O Module <iom slot name> temperature exceeded operating range. | ||
| 1.3.6.1.4.1.674.10892.2.21.8306 | Nodealert2Unable2ReadTemperatureSensors | Unable to read planar board temperature sensors. The cooling has been increased to safeguard the system. | ||
| 1.3.6.1.4.1.674.10892.2.21.8329 | Nodealert2PowerSupplyAuditFailure | Power Supply audit failure or critical event. | ||
| 1.3.6.1.4.1.674.10892.2.21.8330 | Nodealert2PowerSupplyAuditWarning | Power Supply audit warning. | ||
| 1.3.6.1.4.1.674.10892.2.21.8331 | Nodealert2PowerSupplyRedundancyPolicyChanged | PSU redundancy policy changed. | ||
| 1.3.6.1.4.1.674.10892.2.21.8361 | Nodealert2SoftwareChangeAuditFailure | Software change audit failure or critical event. | ||
| 1.3.6.1.4.1.674.10892.2.21.8417 | Nodealert2PowerUsageAuditFailure | Power usage audit failure or critical event. | ||
| 1.3.6.1.4.1.674.10892.2.21.8418 | Nodealert2PowerUsageAuditWarning | Power usage audit warning. | ||
| 1.3.6.1.4.1.674.10892.2.21.8419 | Nodealert2PowerUsageAuditInformation | Power usage audit information. | ||
| 1.3.6.1.4.1.674.10892.2.21.8513 | Nodealert2LicenseFailure | License failure. | ||
| 1.3.6.1.4.1.674.10892.2.21.8514 | Nodealert2LicenseWarning | License warning. | ||
| 1.3.6.1.4.1.674.10892.2.21.8515 | Nodealert2LicenseInformation | License information. | ||
| 1.3.6.1.4.1.674.10892.2.21.8562 | Nodealert2PCIDeviceAuditWarning | PCI device audit warning. | ||
| 1.3.6.1.4.1.674.10892.2.21.8689 | Nodealert2CMCAuditFailure | Chassis Management Controller audit failure or critical event. | ||
| 1.3.6.1.4.1.674.10892.2.21.8690 | Nodealert2CMCAuditWarning | Chassis Management Controller audit warning. | ||
| 1.3.6.1.4.1.674.10892.2.21.8691 | Nodealert2CMCAuditInformation | Chassis Management Controller audit information. | ||
| 1.3.6.1.4.1.674.10892.2.21.8698 | Nodealert2IOVirtualizationAuditWarning | IO Virtualization audit warning. | ||
| 1.3.6.1.4.1.674.10892.2.21.10395 | Nodealert2CMCTestTrap | Test trap generated by CMC in response to a user request. | ||
| 1.3.6.1.4.1.674.10892.2.21.10529 | Nodealert2SWCConfigurationFailure | Software configuration failure. | ||
| 1.3.6.1.4.1.674.10892.2.21.10530 | Nodealert2SWCConfigurationWarning | Software configuration warning. | ||
| 1.3.6.1.4.1.674.10892.2.21.10611 | Nodealert2PCIDeviceConfigurationInformation | PCI device configuration information. | ||
| 1.3.6.1.4.1.674.10892.2.21.10746 | Nodealert2IOVConfigurationWarning | IO Virtualization configuration warning. | ||
| 1.3.6.1.4.1.674.10892.2.21.10747 | Nodealert2IOVConfigurationInformation | IO Virtualization configuration information. | ||
| 1.3.6.1.4.1.674.10892.2.1001 | NodealertDrscTestTrapEvent | The RAC generated a test trap event in response to a user request. | ||
| 1.3.6.1.4.1.674.10892.2.1002 | NodealertDrscAuthError | The RAC Authentication Failures during a time period have Exceeded a Threshold. | ||
| 1.3.6.1.4.1.674.10892.2.1003 | NodealertDrscLostESM | The RAC cannot communicate with the baseboard management controller (ESM). | ||
| 1.3.6.1.4.1.674.10892.2.1004 | NodealertDrscFoundESM | The RAC is communicating normally with the baseboard management controller (ESM). | ||
| 1.3.6.1.4.1.674.10892.2.1005 | NodealertDrscPowerOff | The RAC has detected a System power state change to powered-off. | ||
| 1.3.6.1.4.1.674.10892.2.1006 | NodealertDrscPowerOn | The RAC has detected a system power state change to powered-on. | ||
| 1.3.6.1.4.1.674.10892.2.1007 | NodealertDrscWatchdogExpired | The RAC has detected that the system watchdog has expired indicating a system hang. | ||
| 1.3.6.1.4.1.674.10892.2.1008 | NodealertDrscBattLow | The RAC Battery charge is below 25% indicating that the battery may only be able to power the DRSC for 8-10 minutes. | ||
| 1.3.6.1.4.1.674.10892.2.1009 | NodealertDrscTempNormal | The RAC Temperature probe has retured to a normal value. | ||
| 1.3.6.1.4.1.674.10892.2.1010 | NodealertDrscTempWarning | The RAC Temperature probe has detected a Warning value. | ||
| 1.3.6.1.4.1.674.10892.2.1011 | NodealertDrscTempCritical | The RAC Temperature probe has detected a failure (or critical) value. | ||
| 1.3.6.1.4.1.674.10892.2.1012 | NodealertDrscVoltNormal | The RAC voltage has returned to a normal value. | ||
| 1.3.6.1.4.1.674.10892.2.1013 | NodealertDrscVoltWarning | The RAC voltage probe has detected a warning value. | ||
| 1.3.6.1.4.1.674.10892.2.1014 | NodealertDrscVoltCritical | The RAC voltage probe has detected a failure (or critical) value. | ||
| 1.3.6.1.4.1.674.10892.2.1015 | NodealertDrscSELWarning | The RAC has detected a new event in the System Event Log with Severity: Warning. | ||
| 1.3.6.1.4.1.674.10892.2.1016 | NodealertDrscSELCritical | The RAC has detected a new event in the System Event Log with Severity: Critical. | ||
| 1.3.6.1.4.1.674.10892.2.1017 | NodealertDrscSEL80percentFull | The RAC has detected that the System Event Log is 80% full. | ||
| 1.3.6.1.4.1.674.10892.2.1018 | NodealertDrscSEL90percentFull | The RAC has detected that the System Event Log is 90% full. | ||
| 1.3.6.1.4.1.674.10892.2.1019 | NodealertDrscSEL100percentFull | The RAC has detected that the System Event Log is 100% full. | ||
| 1.3.6.1.4.1.674.10892.2.1020 | NodealertDrscSELNormal | The RAC has detected a new event in the System Event Log with Severity: Normal. | ||
| 1.3.6.1.4.1.674.10892.2.2000 | NodealertCMCTestTrap | The CMC has generated a test trap | ||
| 1.3.6.1.4.1.674.10892.2.2002 | NodealertCMCNormalTrap | The CMC reported a return-to-normal or informational event. | ||
| 1.3.6.1.4.1.674.10892.2.2003 | NodealertCMCWarningTrap | The CMC reported a warning event. | ||
| 1.3.6.1.4.1.674.10892.2.2004 | NodealertCMCCriticalTrap | The CMC reported a critical event. | ||
| 1.3.6.1.4.1.674.10892.2.2005 | NodealertCMCNonRecoverableTrap | The CMC reported a catastrophic event. | ||
| 1.3.6.1.4.1.674.10892.2.5000 | NodedrsAlertGroup | |||
| 1.3.6.1.4.1.674.10892.2.5000.10 | NodedrsAlertVariables | |||
| 1.3.6.1.4.1.674.10892.2.5000.10.1 | ScalardrsAlertSystem | read-only | mandatory | 5000.0010.0001 Name of the system generating the alert. |
| 1.3.6.1.4.1.674.10892.2.5000.10.2 | ScalardrsAlertTableIndexOID | read-only | mandatory | 5000.0010.0002 0.0 |
| 1.3.6.1.4.1.674.10892.2.5000.10.3 | ScalardrsAlertMessage | read-only | mandatory | 5000.0010.0003 Message describing the alert. |
| 1.3.6.1.4.1.674.10892.2.5000.10.4 | ScalardrsAlertCurrentStatus | read-only | mandatory | 5000.0010.0004 Current status of object causing the alert. |
| 1.3.6.1.4.1.674.10892.2.5000.10.5 | ScalardrsAlertPreviousStatus | read-only | mandatory | 5000.0010.0005 Previous status of object causing the alert. |
| 1.3.6.1.4.1.674.10892.2.5000.10.6 | ScalardrsAlertData | read-only | mandatory | 5000.0010.0006 Alert data. |