MIB Viewer

DELL-RAC-MIB

446 objects
No module-level DESCRIPTION found.
Imported Objects
RFC-1212OBJECT-TYPE
RFC-1215TRAP-TYPE
RFC1155-SMIenterprises TimeTicks
RFC1213-MIBDisplayString
OIDNameAccessStatusDescription
1.3.6.1.4.1.674Nodedell
1.3.6.1.4.1.674.10892Nodeserver3
1.3.6.1.4.1.674.10892.2NodedrsOutofBandGroup
1.3.6.1.4.1.674.10892.2.1NodedrsInformationGroup
1.3.6.1.4.1.674.10892.2.1.1NodedrsProductInfoGroup
1.3.6.1.4.1.674.10892.2.1.1.1ScalardrsProductNameread-onlymandatory0001.0001.0001 This attribute defines the product name of a chassis management controller.
1.3.6.1.4.1.674.10892.2.1.1.2ScalardrsProductShortNameread-onlymandatory0001.0001.0002 This attribute defines the short product name of a chassis management controller.
1.3.6.1.4.1.674.10892.2.1.1.3ScalardrsProductDescriptionread-onlymandatory0001.0001.0003 This attribute defines the product description of a chassis management controller.
1.3.6.1.4.1.674.10892.2.1.1.4ScalardrsProductManufacturerread-onlymandatory0001.0001.0004 This attribute defines the product manufacturer of a chassis management controller.
1.3.6.1.4.1.674.10892.2.1.1.5ScalardrsProductVersionread-onlymandatory0001.0001.0005 This attribute defines the product version of a chassis management controller.
1.3.6.1.4.1.674.10892.2.1.1.6ScalardrsChassisServiceTagread-onlymandatory0001.0001.0007 This attribute defines the Service Tag of the chassis.
1.3.6.1.4.1.674.10892.2.1.1.7ScalardrsProductURLread-onlymandatory0001.0001.0006 This attribute defines the out-of-band UI URL of a chassis management controller.
1.3.6.1.4.1.674.10892.2.1.1.8ScalardrsProductChassisAssetTagread-onlymandatory0001.0001.0008 This attribute defines the Asset Tag of the chassis.
1.3.6.1.4.1.674.10892.2.1.1.9ScalardrsProductChassisLocationread-onlymandatory0001.0001.0009 This attribute defines the location of the chassis.
1.3.6.1.4.1.674.10892.2.1.1.10ScalardrsProductChassisNameread-onlymandatory0001.0001.0010 This attribute defines the name of the chassis.
1.3.6.1.4.1.674.10892.2.1.1.11ScalardrsSystemServiceTagread-onlymandatory0001.0001.0011 This attribute defines the service tag of a system.
1.3.6.1.4.1.674.10892.2.1.1.12ScalardrsProductSystemAssetTagread-onlymandatory0001.0001.0012 This attribute defines the asset tag of a system.
1.3.6.1.4.1.674.10892.2.1.1.13ScalardrsProductSystemSlotread-onlymandatory0001.0001.0013 This attribute defines the slot number of a CMC.
1.3.6.1.4.1.674.10892.2.1.1.14ScalardrsProductTyperead-onlymandatory0001.0001.0014 This attribute defines type of a remote access card
1.3.6.1.4.1.674.10892.2.1.1.15ScalardrsProductChassisDataCenterread-onlymandatory0001.0001.0015 This attribute defines the Data Center locator of the chassis.
1.3.6.1.4.1.674.10892.2.1.1.16ScalardrsProductChassisAisleread-onlymandatory0001.0001.0016 This attribute defines the Aisle locator of the chassis.
1.3.6.1.4.1.674.10892.2.1.1.17ScalardrsProductChassisRackread-onlymandatory0001.0001.0017 This attribute defines the Rack locator of the chassis.
1.3.6.1.4.1.674.10892.2.1.1.18ScalardrsProductChassisRackSlotread-onlymandatory0001.0001.0018 This attribute defines the Rack Slot locator of the chassis.
1.3.6.1.4.1.674.10892.2.1.1.19ScalardrsProductChassisModelread-onlymandatory0001.0001.0019 This attribute defines the Model of the chassis.
1.3.6.1.4.1.674.10892.2.1.1.20ScalardrsProductChassisExpressServiceCoderead-onlymandatory0001.0001.0020 This attribute defines the Express Service Code of the chassis.
1.3.6.1.4.1.674.10892.2.1.1.21ScalardrsProductChassisSystemIDread-onlymandatory0001.0001.0021 This attribute defines the System ID of the chassis.
1.3.6.1.4.1.674.10892.2.1.1.22ScalardrsProductChassisSizeread-onlymandatory0001.0001.0022 This attribute defines the size of the chassis in rack units (U). A U is a standard unit of measure for the height of a rack or rack-mountable c…
1.3.6.1.4.1.674.10892.2.1.2NodedrsFirmwareGroup
1.3.6.1.4.1.674.10892.2.1.2.1ScalardrsFirmwareVersionread-onlymandatory0001.0002.0001 This attribute defines the firmware version of chassis management controller 1.
1.3.6.1.4.1.674.10892.2.1.2.2ScalardrsiKVMFirmwareVersionread-onlymandatory0001.0002.0002 This attribute defines the firmware version of the iKVM.
1.3.6.1.4.1.674.10892.2.1.2.3ScalardrsFirmwareVersion2read-onlymandatory0001.0002.0003 This attribute defines the firmware version of chassis management controller 2.
1.3.6.1.4.1.674.10892.2.2NodedrsStatusGroup
1.3.6.1.4.1.674.10892.2.2.1ScalardrsGlobalSystemStatusread-onlymandatory0002.0001.0001 This attribute defines the overall chassis status being monitored by the chassis management card.
1.3.6.1.4.1.674.10892.2.3NodedrsChassisStatusGroup
1.3.6.1.4.1.674.10892.2.3.1NodedrsStatusNowGroup
1.3.6.1.4.1.674.10892.2.3.1.1ScalardrsGlobalCurrStatusread-onlymandatory0003.0001.0001 This attribute defines the overall chassis status being monitored by the chassis management card.
1.3.6.1.4.1.674.10892.2.3.1.2ScalardrsIOMCurrStatusread-onlymandatory0003.0001.0002 This attribute defines the IOM subsystem status being monitored by the chassis management card.
1.3.6.1.4.1.674.10892.2.3.1.3ScalardrsKVMCurrStatusread-onlymandatory0003.0001.0003 This attribute defines the iKVM subsystem health status being monitored by the chassis management card.
1.3.6.1.4.1.674.10892.2.3.1.4ScalardrsRedCurrStatusread-onlymandatory0003.0001.0004 This attribute defines the Redundancy status being monitored by the chassis management card.
1.3.6.1.4.1.674.10892.2.3.1.5ScalardrsPowerCurrStatusread-onlymandatory0003.0001.0005 This attribute defines the power subsystem health status being monitored by the chassis management card.
1.3.6.1.4.1.674.10892.2.3.1.6ScalardrsFanCurrStatusread-onlymandatory0003.0001.0006 This attribute defines the Fan subsystem health status being monitored by the chassis management card.
1.3.6.1.4.1.674.10892.2.3.1.7ScalardrsBladeCurrStatusread-onlymandatory0003.0001.0007 This attribute defines the Blade subsystem health status being monitored by the chassis management card.
1.3.6.1.4.1.674.10892.2.3.1.8ScalardrsTempCurrStatusread-onlymandatory0003.0001.0008 This attribute defines the Temp Sensor subsystem health status being monitored by the chassis management card.
1.3.6.1.4.1.674.10892.2.3.1.9ScalardrsCMCCurrStatusread-onlymandatory0003.0001.0009 This attribute defines the CMC health status being monitored by the chassis management card.
1.3.6.1.4.1.674.10892.2.3.1.10ScalardrsChassisFrontPanelAmbientTemperatureread-onlymandatory0003.0001.0010 This attribute defines the ambient temperature reading (in degrees Celsius) for the chassis front panel controller.
1.3.6.1.4.1.674.10892.2.3.1.11ScalardrsCMCAmbientTemperatureread-onlymandatory0003.0001.0011 This attribute defines the ambient temperature reading (in degrees Celsius) for the chassis management card.
1.3.6.1.4.1.674.10892.2.3.1.12ScalardrsCMCProcessorTemperatureread-onlymandatory0003.0001.0012 This attribute defines the temperature reading (in degrees Celsius) for the chassis management card processor.
1.3.6.1.4.1.674.10892.2.3.2NodedrsStatusPrevGroup
1.3.6.1.4.1.674.10892.2.3.2.1ScalardrsGlobalPrevStatusread-onlymandatory0003.0002.0001 This attribute defines the previous chassis status recorded by the chassis management card.
1.3.6.1.4.1.674.10892.2.3.2.2ScalardrsIOMPrevStatusread-onlymandatory0003.0002.0002 This attribute defines the previous IOM subsystem status recorded by the chassis management card.
1.3.6.1.4.1.674.10892.2.3.2.3ScalardrsKVMPrevStatusread-onlymandatory0003.0002.0003 This attribute defines the previous iKVM subsystem health status recorded by the chassis management card.
1.3.6.1.4.1.674.10892.2.3.2.4ScalardrsRedPrevStatusread-onlymandatory0003.0002.0004 This attribute defines the previous Redundancy status recorded by the chassis management card.
1.3.6.1.4.1.674.10892.2.3.2.5ScalardrsPowerPrevStatusread-onlymandatory0003.0002.0005 This attribute defines the previous power subsystem health status recorded by the chassis management card.
1.3.6.1.4.1.674.10892.2.3.2.6ScalardrsFanPrevStatusread-onlymandatory0003.0002.0006 This attribute defines the previous Fan health status being monitored by the chassis management card.
1.3.6.1.4.1.674.10892.2.3.2.7ScalardrsBladePrevStatusread-onlymandatory0003.0002.0007 This attribute defines the previous Blade subsystem health status recorded by the chassis management card.
1.3.6.1.4.1.674.10892.2.3.2.8ScalardrsTempPrevStatusread-onlymandatory0003.0001.0008 This attribute defines the Temp Sensor health status being monitored by the chassis management card.
1.3.6.1.4.1.674.10892.2.3.2.9ScalardrsCMCPrevStatusread-onlymandatory0003.0001.0009 This attribute defines the CMC health status being monitored by the chassis management card.
1.3.6.1.4.1.674.10892.2.3.3NodedrsStatusChangeGroup
1.3.6.1.4.1.674.10892.2.3.3.1ScalardrsGlobalChangeTimeread-onlymandatory0003.0003.0001 This attribute defines the timestamp of the most recent global status change.
1.3.6.1.4.1.674.10892.2.3.3.2ScalardrsIOMChangeTimeread-onlymandatory0003.0003.0002 This attribute defines the timestamp of the most recent IOM status change.
1.3.6.1.4.1.674.10892.2.3.3.3ScalardrsKVMChangeTimeread-onlymandatory0003.0003.0003 This attribute defines the timestamp of the most recent iKVM status change.
1.3.6.1.4.1.674.10892.2.3.3.4ScalardrsRedChangeTimeread-onlymandatory0003.0003.0004 This attribute defines the timestamp of the most recent Redundancy status change.
1.3.6.1.4.1.674.10892.2.3.3.5ScalardrsPowerChangeTimeread-onlymandatory0003.0003.0005 This attribute defines the timestamp of the most recent power health status change.
1.3.6.1.4.1.674.10892.2.3.3.6ScalardrsFanChangeTimeread-onlymandatory0003.0003.0006 This attribute defines the timestamp of the most recent Fan health status change.
1.3.6.1.4.1.674.10892.2.3.3.7ScalardrsBladeChangeTimeread-onlymandatory0003.0003.0007 This attribute defines the timestamp of the most recent Blade health status change.
1.3.6.1.4.1.674.10892.2.3.3.8ScalardrsTempChangeTimeread-onlymandatory0003.0003.0008 This attribute defines the timestamp of the most recent Temp Sensor health status change.
1.3.6.1.4.1.674.10892.2.3.3.9ScalardrsCMCChangeTimeread-onlymandatory0003.0003.0009 This attribute defines the timestamp of the most recent CMC health status change.
1.3.6.1.4.1.674.10892.2.4NodedrsChassisPowerGroup
1.3.6.1.4.1.674.10892.2.4.1TabledrsCMCPowerTablenot-accessiblemandatory0004.0001 This object defines the CMC power table.
1.3.6.1.4.1.674.10892.2.4.1.1RowdrsCMCPowerTableEntrynot-accessiblemandatory0004.0001.0001 This object defines the CMC power table entry.
1.3.6.1.4.1.674.10892.2.4.1.1.1ColumndrsChassisIndexread-onlymandatory0004.0001.0001.0001 This attribute defines the index (one-based) of the associated chassis.
1.3.6.1.4.1.674.10892.2.4.1.1.2ColumndrsPotentialPowerread-onlymandatory0004.0001.0001.0002 This attribute defines the power (in Watts) required by the chassis infrastructure, plus the sum of the maximum power requirements for all …
1.3.6.1.4.1.674.10892.2.4.1.1.3ColumndrsIdlePowerread-onlymandatory0004.0001.0001.0003 This attribute defines the power (in Watts) required by the chassis infrastructure, plus the sum of the minimum power requirements for all …
1.3.6.1.4.1.674.10892.2.4.1.1.4ColumndrsMaxPowerSpecificationread-onlymandatory0004.0001.0001.0004 This attribute defines the power limit (in Watts) at which server throttling will take place.
1.3.6.1.4.1.674.10892.2.4.1.1.5ColumndrsPowerSurplusread-onlymandatory0004.0001.0001.0005 This attribute defines the power surplus (in Watts) remaining above the drsPotentialPower reading.
1.3.6.1.4.1.674.10892.2.4.1.1.6ColumndrsKWhCumulativeread-onlymandatory0004.0001.0001.0006 This attribute defines the cumulative chassis power usage (in KWh) since last reset.
1.3.6.1.4.1.674.10892.2.4.1.1.7ColumndrsKWhCumulativeTimeread-onlymandatory0004.0001.0001.0007 This attribute defines the timestamp of the most recent chassis power accumulator reset.
1.3.6.1.4.1.674.10892.2.4.1.1.8ColumndrsWattsPeakUsageread-onlymandatory0004.0001.0001.0008 This attribute defines the chassis peak power usage (in Watts) since last reset.
1.3.6.1.4.1.674.10892.2.4.1.1.9ColumndrsWattsPeakTimeread-onlymandatory0004.0001.0001.0009 This attribute defines the timestamp of the most recent chassis peak power usage.
1.3.6.1.4.1.674.10892.2.4.1.1.10ColumndrsWattsMinUsageread-onlymandatory0004.0001.0001.0010 This attribute defines the chassis mimimum power usage (in Watts) since last reset.
1.3.6.1.4.1.674.10892.2.4.1.1.11ColumndrsWattsMinTimeread-onlymandatory0004.0001.0001.0011 This attribute defines the timestamp of the most recent chassis minimum power usage.
1.3.6.1.4.1.674.10892.2.4.1.1.12ColumndrsWattsResetTimeread-onlymandatory0004.0001.0001.0012 This attribute defines the timestamp of the most recent reset of the chassis min/peak Watts readings.
1.3.6.1.4.1.674.10892.2.4.1.1.13ColumndrsWattsReadingread-onlymandatory0004.0001.0001.0013 This attribute defines the instantaneous chassis power usage (in Watts).
1.3.6.1.4.1.674.10892.2.4.1.1.14ColumndrsAmpsReadingread-onlymandatory0004.0001.0001.0014 This attribute defines the instantaneous chassis current usage (in Watts).
1.3.6.1.4.1.674.10892.2.4.2TabledrsCMCPSUTablenot-accessiblemandatory0004.0002 This object defines the CMC PSU table.
1.3.6.1.4.1.674.10892.2.4.2.1RowdrsCMCPSUTableEntrynot-accessiblemandatory0004.0002.0001 This object defines the CMC PSU table entry.
1.3.6.1.4.1.674.10892.2.4.2.1.1ColumndrsPSUChassisIndexread-onlymandatory0004.0002.0001.0001 This attribute defines the index (one-based) of the associated chassis.
1.3.6.1.4.1.674.10892.2.4.2.1.2ColumndrsPSUIndexread-onlymandatory0004.0002.0001.0002 This attribute defines the index (one-based) of the associated CMC PSU.
1.3.6.1.4.1.674.10892.2.4.2.1.3ColumndrsPSULocationread-onlymandatory0004.0002.0001.0003 This attribute defines the location of the CMC PSU.
1.3.6.1.4.1.674.10892.2.4.2.1.4ColumndrsPSUMonitoringCapableread-onlymandatory0004.0002.0001.0004 This attribute defines the PSU Monitoring capabilities, or the absence of a PSU in this location.
1.3.6.1.4.1.674.10892.2.4.2.1.5ColumndrsPSUVoltsReadingread-onlymandatory0004.0002.0001.0005 This attribute defines the instantaneous PSU Voltage reading.
1.3.6.1.4.1.674.10892.2.4.2.1.6ColumndrsPSUAmpsReadingread-onlymandatory0004.0002.0001.0006 This attribute defines the instantaneous PSU Current reading.
1.3.6.1.4.1.674.10892.2.4.2.1.7ColumndrsPSUWattsReadingread-onlymandatory0004.0002.0001.0007 This attribute defines the instantaneous PSU Wattage reading.
1.3.6.1.4.1.674.10892.2.5NodedrsChassisServerGroup
1.3.6.1.4.1.674.10892.2.5.1TabledrsCMCServerTablenot-accessiblemandatory0005.0001 This object defines the CMC server table.
1.3.6.1.4.1.674.10892.2.5.1.1RowdrsCMCServerTableEntrynot-accessiblemandatory0005.0001.0001 This object defines the CMC server table entry.
1.3.6.1.4.1.674.10892.2.5.1.1.1ColumndrsServerIndexread-onlymandatory0005.0001.0001.0001 This attribute defines the index (one-based) of the associated CMC server.
1.3.6.1.4.1.674.10892.2.5.1.1.2ColumndrsServerMonitoringCapableread-onlymandatory0005.0001.0001.0002 This attribute defines the server monitoring capabilities, or the absence of a server in this location.
1.3.6.1.4.1.674.10892.2.5.1.1.3ColumndrsServerServiceTagread-onlymandatory0005.0001.0001.0003 This attribute defines the Service Tag of the CMC server.
1.3.6.1.4.1.674.10892.2.5.1.1.4ColumndrsServerSlotNameread-onlymandatory0005.0001.0001.0004 This attribute defines the Slot Name of the CMC server.
1.3.6.1.4.1.674.10892.2.5.1.1.5ColumndrsServerSlotNumberread-onlymandatory0005.0001.0001.0005 This attribute defines the Chassis Slot Number of the CMC server.
1.3.6.1.4.1.674.10892.2.5.1.1.6ColumndrsServerNodeIDread-onlymandatory0005.0001.0001.0006 This attribute defines the Node ID of the CMC server. The Node ID provides a unique identifier for the server.
1.3.6.1.4.1.674.10892.2.5.1.1.7ColumndrsServerModelread-onlymandatory0005.0001.0001.0007 This attribute defines the Model of the CMC server.
1.3.6.1.4.1.674.10892.2.5.1.1.8ColumndrsServerAssetTagread-onlymandatory0005.0001.0001.0008 This attribute defines the Asset Tag of the CMC server.
1.3.6.1.4.1.674.10892.2.5.1.1.9ColumndrsServerNumStorageControllersread-onlymandatory0005.0001.0001.0009 This attribute defines the number of storage controllers on the storage sled. The value will be zero if this is not a storage sled.
1.3.6.1.4.1.674.10892.2.5.1.1.10ColumndrsServerStorageModeread-onlymandatory0005.0001.0001.0010 This attribute defines the Storage Mode of the storage sled.
1.3.6.1.4.1.674.10892.2.5.1.1.11ColumndrsServerIntrusionStateread-onlymandatory0005.0001.0001.0011 This attribute defines the Intrusion State of the CMC server if supported by the server.
1.3.6.1.4.1.674.10892.2.5.1.1.12ColumndrsServerAssignedServerSlotsread-onlymandatory0005.0001.0001.0012 This attribute defines the the server slots to which a storage sled is assigned. If this is a storage sled that is assigned to one more or …
1.3.6.1.4.1.674.10892.2.6NodestorageDetailsGroup
1.3.6.1.4.1.674.10892.2.6.1Nodesoftware
1.3.6.1.4.1.674.10892.2.6.1.20NodestorageManagement
1.3.6.1.4.1.674.10892.2.6.1.20.130NodephysicalDevices
1.3.6.1.4.1.674.10892.2.6.1.20.130.1TablecontrollerTablenot-accessiblemandatoryA table of managed RAID controllers. The number of entries is related to number of RAID controllers discovered in the system. The maximum number of entries is …
1.3.6.1.4.1.674.10892.2.6.1.20.130.1.1RowcontrollerTableEntrynot-accessiblemandatoryAn entry in the table of RAID controllers. A row in this table cannot be created or deleted by SNMP operations on columns of the table.
1.3.6.1.4.1.674.10892.2.6.1.20.130.1.1.1ColumncontrollerNumberread-onlymandatoryInstance number of this controller entry.
1.3.6.1.4.1.674.10892.2.6.1.20.130.1.1.2ColumncontrollerNameread-onlymandatoryThe controller's name as represented in Storage Management.
1.3.6.1.4.1.674.10892.2.6.1.20.130.1.1.7ColumncontrollerRebuildRateread-onlymandatoryThe rebuild rate is the percentage of the controller's resources dedicated to rebuilding a failed disk when a rebuild is necessary.
1.3.6.1.4.1.674.10892.2.6.1.20.130.1.1.8ColumncontrollerFWVersionread-onlymandatoryThe controller's current firmware version.
1.3.6.1.4.1.674.10892.2.6.1.20.130.1.1.9ColumncontrollerCacheSizeInMBread-onlymandatoryThe controller's current amount of cache memory in megabytes.
1.3.6.1.4.1.674.10892.2.6.1.20.130.1.1.37ColumncontrollerRollUpStatusread-onlymandatorySeverity of the controller state. This is the combined status of the controller and its components. Possible values: 1: Other. 2: Unknown. 3: OK 4: Non-critica…
1.3.6.1.4.1.674.10892.2.6.1.20.130.1.1.38ColumncontrollerComponentStatusread-onlymandatoryThe status of the controller itself without the propagation of any contained component status. Possible values: 1: Other 2: Unknown 3: OK 4: Non-critical 5: Cr…
1.3.6.1.4.1.674.10892.2.6.1.20.130.1.1.41ColumncontrollerDriverVersionread-onlymandatoryCurrently installed driver version for this controller on the host.
1.3.6.1.4.1.674.10892.2.6.1.20.130.1.1.42ColumncontrollerPCISlotread-onlymandatoryThe PCI slot on the server where the controller is seated. This data is not reported for embedded or integrated controllers,
1.3.6.1.4.1.674.10892.2.6.1.20.130.1.1.48ColumncontrollerReconstructRateread-onlymandatoryThe reconstruct rate is the percentage of the controller's resources dedicated to reconstructing a disk group after adding a physical disk or changing the RAID…
1.3.6.1.4.1.674.10892.2.6.1.20.130.1.1.49ColumncontrollerPatrolReadRateread-onlymandatoryThe patrol read rate is the percentage of the controller's resources dedicated to perform a patrol read on disks participating in a virtual disk or hot spares.
1.3.6.1.4.1.674.10892.2.6.1.20.130.1.1.50ColumncontrollerBGIRateread-onlymandatoryThe background initialization (BGI) rate is the percentage of the controller's resources dedicated to performing the background initialization of a redundant v…
1.3.6.1.4.1.674.10892.2.6.1.20.130.1.1.51ColumncontrollerCheckConsistencyRateread-onlymandatoryThe check consistency rate is the percentage of the controller's resources dedicated to performing a check consistency on a redundant virtual disk.
1.3.6.1.4.1.674.10892.2.6.1.20.130.1.1.52ColumncontrollerPatrolReadModeread-onlymandatoryIdentifies the patrol read mode setting for the controller. Possible values: 1: Not one of the following or could not be determined. 2: Not Supported on this c…
1.3.6.1.4.1.674.10892.2.6.1.20.130.1.1.53ColumncontrollerPatrolReadStateread-onlymandatoryThis property displays the current state of the patrol read process. Possible values: 1: Not one of the following or could not be determined. 2: Patrol read is…
1.3.6.1.4.1.674.10892.2.6.1.20.130.1.1.59ColumncontrollerPersistentHotSpareread-onlymandatoryIndicates whether hot spare drives would be restored on insertion into the same slot.
1.3.6.1.4.1.674.10892.2.6.1.20.130.1.1.60ColumncontrollerSpinDownUnconfiguredDrivesread-onlymandatoryIndicates whether un-configured drives would be put in power save mode by the controller.
1.3.6.1.4.1.674.10892.2.6.1.20.130.1.1.61ColumncontrollerSpinDownHotSpareDrivesread-onlymandatoryIndicates whether hot spare drives would be put in power save mode by the controller.
1.3.6.1.4.1.674.10892.2.6.1.20.130.1.1.62ColumncontrollerSpinDownTimeIntervalread-onlymandatoryThe duration in minutes after which, the unconfigured or hot spare drives will be spun down to power save mode.
1.3.6.1.4.1.674.10892.2.6.1.20.130.1.1.69ColumncontrollerPreservedCacheread-onlymandatoryIndicates whether preserved cache or pinned cache is present on the controller.
1.3.6.1.4.1.674.10892.2.6.1.20.130.1.1.70ColumncontrollerCheckConsistencyModeread-onlymandatoryThe current check consistency mode setting for the controller. Possible values: 1: Not one of the following. 2: Not supported on this controller. 3: Normal che…
1.3.6.1.4.1.674.10892.2.6.1.20.130.1.1.71ColumncontrollerCopyBackModeread-onlymandatoryThe current copy back mode setting for the controller. Possible values: 1: Not one of the following. 2: Not supported on this controller. 3: Disks assigned as …
1.3.6.1.4.1.674.10892.2.6.1.20.130.1.1.72ColumncontrollerSecurityStatusread-onlymandatoryThe controller's current security/encryption status.. Possible values: 1: The current status could not be determined. 2: Controller is not operating in an encr…
1.3.6.1.4.1.674.10892.2.6.1.20.130.1.1.73ColumncontrollerEncryptionKeyPresentread-onlymandatoryIndicates whether encryption key is assigned for the controller.
1.3.6.1.4.1.674.10892.2.6.1.20.130.1.1.74ColumncontrollerEncryptionCapabilityread-onlymandatoryThe type of encryption supported by the controller. Possible values: 1: Not one of the following. 2: No encryption supported, 3: Local Key Management,
1.3.6.1.4.1.674.10892.2.6.1.20.130.1.1.75ColumncontrollerLoadBalanceSettingread-onlymandatoryThe ability of the controller to automatically use both controller ports (or connectors) connected to the same enclosure in order to route I/O requests. Possib…
1.3.6.1.4.1.674.10892.2.6.1.20.130.1.1.76ColumncontrollerMaxCapSpeedread-onlymandatoryThe maximum speed of the controller.in Gigbits per second (Gbps). Possible values: 1: The speed could not be determined. 2. 1.5 Gbps 3: 3.0 Gbps 4: 6.0 Gbps 5:…
1.3.6.1.4.1.674.10892.2.6.1.20.130.1.1.77ColumncontrollerSASAddressread-onlymandatoryThe SAS address of the controller.
1.3.6.1.4.1.674.10892.2.6.1.20.130.1.1.78ColumncontrollerFQDDread-onlymandatoryThe controller's Fully Qualified Device Descriptor (FQDD) as represented in Storage Management.
1.3.6.1.4.1.674.10892.2.6.1.20.130.1.1.79ColumncontrollerDisplayNameread-onlymandatoryThe controller's friendly FQDD as represented in Storage Management.
1.3.6.1.4.1.674.10892.2.6.1.20.130.1.1.80ColumncontrollerT10PICapabilityread-onlymandatoryIndicates whether the controller supports the T10 PI (Protection Information). These protection fields are known as DIF (Data Integrity Fields). Possible value…
1.3.6.1.4.1.674.10892.2.6.1.20.130.1.1.81ColumncontrollerRAID10UnevenSpansSupportedread-onlymandatoryIndicates whether uneven spans for RAID 10 virtual disk is supported on the controller.
1.3.6.1.4.1.674.10892.2.6.1.20.130.1.1.82ColumncontrollerEnhancedAutoImportForeignConfigModeread-onlymandatoryIndicates the status of enhanced auto-import of foreign configuration property of the controller. 1: Not one of the following. 2: Not Supported. 3: Disabled. 4…
1.3.6.1.4.1.674.10892.2.6.1.20.130.1.1.83ColumncontrollerBootModeSupportedread-onlymandatoryIndicates whether headless boot mode settings are supported on the controller.
1.3.6.1.4.1.674.10892.2.6.1.20.130.1.1.84ColumncontrollerBootModeread-onlymandatoryIndicates the boot mode of the controller. Possible values: 1: Not applicable for this controller. 2: User mode: User interaction required for all boot message…
1.3.6.1.4.1.674.10892.2.6.1.20.130.1.1.85ColumncontrollerHighAvailabilityModeread-onlymandatoryIndicates the fault-tolerant mode of the controller. Possible values: 1: None 2: Fault Tolerant(Active/Passive) 3: Fault Tolerant(Active/Active) 4: Degraded
1.3.6.1.4.1.674.10892.2.6.1.20.130.1.1.86ColumncontrollerPeerControllerread-onlymandatoryThe peer controller's Fully Qualified Device Descriptor (FQDD) as represented in Storage Management.
1.3.6.1.4.1.674.10892.2.6.1.20.130.1.1.87ColumncontrollerEncryptionKeyIdentifierread-onlymandatoryDisplays the encryption security key identifier of the controller, if the controller is encryption enabled and a security key is configured for the controller.
1.3.6.1.4.1.674.10892.2.6.1.20.130.3TableenclosureTablenot-accessiblemandatoryA table of managed enclosures/backplanes. The number of entries is related to number of internal backplane(s) discovered in the system and external storage enc…
1.3.6.1.4.1.674.10892.2.6.1.20.130.3.1RowenclosureTableEntrynot-accessiblemandatoryAn entry in the enclosure table. A row in this table cannot be created or deleted by SNMP operations on columns of the table.
1.3.6.1.4.1.674.10892.2.6.1.20.130.3.1.1ColumnenclosureNumberread-onlymandatoryInstance number of this enclossre/backplane.
1.3.6.1.4.1.674.10892.2.6.1.20.130.3.1.2ColumnenclosureNameread-onlymandatoryThe enclosure/backplane's name as represented in Storage Management.
1.3.6.1.4.1.674.10892.2.6.1.20.130.3.1.4ColumnenclosureStateread-onlymandatoryThe current state of this enclosure/backplane. Possible states: 1: The current state could not be determined. 2: The enclosure is operating normally. 3: The en…
1.3.6.1.4.1.674.10892.2.6.1.20.130.3.1.8ColumnenclosureServiceTagread-onlymandatoryEnclosure identification used when consulting customer support.
1.3.6.1.4.1.674.10892.2.6.1.20.130.3.1.9ColumnenclosureAssetTagread-onlymandatoryThe asset tag information for the enclosure.
1.3.6.1.4.1.674.10892.2.6.1.20.130.3.1.19ColumnenclosureConnectedPortread-onlymandatoryThe port on the controller to which the storage enclosure is connected.
1.3.6.1.4.1.674.10892.2.6.1.20.130.3.1.23ColumnenclosureRollUpStatusread-onlymandatorySeverity of the enclosure/backplane state. This is the combined status of the enclosure and its sub-components. Possible values: 1: Other. 2: Unknown. 3: OK. 4…
1.3.6.1.4.1.674.10892.2.6.1.20.130.3.1.24ColumnenclosureComponentStatusread-onlymandatoryThe status of the enclosure/backplane.itself without the propagation of any contained component status. Possible values: 1: Other. 2: Unknown. 3: OK. 4: Non-cr…
1.3.6.1.4.1.674.10892.2.6.1.20.130.3.1.26ColumnenclosureFirmwareVersionread-onlymandatoryThe firmware information for the enclosure/backplane.
1.3.6.1.4.1.674.10892.2.6.1.20.130.3.1.30ColumnenclosureSASAddressread-onlymandatoryThe SAS address of the enclosure/backplane.
1.3.6.1.4.1.674.10892.2.6.1.20.130.3.1.31ColumnenclosureDriveCountread-onlymandatoryThe number of disks present in the enclosure/backplane.
1.3.6.1.4.1.674.10892.2.6.1.20.130.3.1.32ColumnenclosureTotalSlotsread-onlymandatoryThe total physical drive slots in a storage enclosure or server backplane.
1.3.6.1.4.1.674.10892.2.6.1.20.130.3.1.40ColumnenclosureFanCountread-onlymandatoryThe number of fans present in the storage enclosure.
1.3.6.1.4.1.674.10892.2.6.1.20.130.3.1.41ColumnenclosurePSUCountread-onlymandatoryThe number of Power Supply Units (PSU) present in the storage enclosure.
1.3.6.1.4.1.674.10892.2.6.1.20.130.3.1.42ColumnenclosureEMMCountread-onlymandatoryThe number of Enclosure Management Modules (EMM) present in the storage enclosure.
1.3.6.1.4.1.674.10892.2.6.1.20.130.3.1.43ColumnenclosureTempProbeCountread-onlymandatoryThe number of temperature sensing devices present in the storage enclosure.
1.3.6.1.4.1.674.10892.2.6.1.20.130.3.1.44ColumnenclosureRedundantPathread-onlymandatoryIndicates whether the controller has multiply paths to reach the storage enclosure.
1.3.6.1.4.1.674.10892.2.6.1.20.130.3.1.45ColumnenclosurePositionread-onlymandatoryThe possition of the storage enclosure within a daisy chain.
1.3.6.1.4.1.674.10892.2.6.1.20.130.3.1.46ColumnenclosureBackplaneBayIDread-onlymandatoryThe unique bay ID of the backplane.
1.3.6.1.4.1.674.10892.2.6.1.20.130.3.1.47ColumnenclosureFQDDread-onlymandatoryThe enclosure/backplane's Fully Qualified Device Descriptor (FQDD) as represented in Storage Management.
1.3.6.1.4.1.674.10892.2.6.1.20.130.3.1.48ColumnenclosureDisplayNameread-onlymandatoryThe enclosure/backplane's friendly FQDD as represented in Storage Management.
1.3.6.1.4.1.674.10892.2.6.1.20.130.3.1.49ColumnenclosureTyperead-onlymandatoryThe protocol supported by the backplane. Possible states: 1: Not one of the following or could not be determined. 2: Not applicable (i.e. object is not a backp…
1.3.6.1.4.1.674.10892.2.6.1.20.130.4TablephysicalDiskTablenot-accessiblemandatoryA table of managed physical disks. The number of entries is related to number of physical Disks discovered in the system. The maximum number of entries is impl…
1.3.6.1.4.1.674.10892.2.6.1.20.130.4.1RowphysicalDiskTableEntrynot-accessiblemandatoryAn entry in the physical Disk table. A row in this table cannot be created or deleted by SNMP operations on columns of the table.
1.3.6.1.4.1.674.10892.2.6.1.20.130.4.1.1ColumnphysicalDiskNumberread-onlymandatoryInstance number of this physical disk entry.
1.3.6.1.4.1.674.10892.2.6.1.20.130.4.1.2ColumnphysicalDiskNameread-onlymandatoryThe physical disk's name as represented in Storage Management.
1.3.6.1.4.1.674.10892.2.6.1.20.130.4.1.3ColumnphysicalDiskManufacturerread-onlymandatoryThe name of the physical disk's manufacturer.
1.3.6.1.4.1.674.10892.2.6.1.20.130.4.1.4ColumnphysicalDiskStateread-onlymandatoryThe current state of this physical disk. Possible states: 1: The current state could not be determined. 2: The physical disk is available for use, but no RAID …
1.3.6.1.4.1.674.10892.2.6.1.20.130.4.1.6ColumnphysicalDiskProductIDread-onlymandatoryThe model number of the physical disk.
1.3.6.1.4.1.674.10892.2.6.1.20.130.4.1.7ColumnphysicalDiskSerialNoread-onlymandatoryThe physical disk's unique identification number from the manufacturer.
1.3.6.1.4.1.674.10892.2.6.1.20.130.4.1.8ColumnphysicalDiskRevisionread-onlymandatoryThe firmware version of the physical disk.
1.3.6.1.4.1.674.10892.2.6.1.20.130.4.1.11ColumnphysicalDiskCapacityInMBread-onlymandatoryThe size of the physical disk in megabytes.
1.3.6.1.4.1.674.10892.2.6.1.20.130.4.1.17ColumnphysicalDiskUsedSpaceInMBread-onlymandatoryThe amount of used space in megabytes on the physical disk. This is not applicable for NVMe devices.
1.3.6.1.4.1.674.10892.2.6.1.20.130.4.1.19ColumnphysicalDiskFreeSpaceInMBread-onlymandatoryThe amount of free space in megabytes on the physical disk. This is not applicable for NVMe devices.
1.3.6.1.4.1.674.10892.2.6.1.20.130.4.1.21ColumnphysicalDiskBusTyperead-onlymandatoryThe bus type of the physical disk. Possible values: 1: The bus type could not be determined. 2: Small Computer System Interface (SCSI). 3: Serial Attached SCSI…
1.3.6.1.4.1.674.10892.2.6.1.20.130.4.1.22ColumnphysicalDiskSpareStateread-onlymandatoryThe status of the disk as a spare. Possible values: 1: Physical disk is not a spare. 2: Physical disk is a dedicated hot spare. 3: Physical disk is a global ho…
1.3.6.1.4.1.674.10892.2.6.1.20.130.4.1.24ColumnphysicalDiskComponentStatusread-onlymandatoryThe status of the physical disk itself without the propagation of any contained component status. Possible values: 1: Other 2: Unknown 3: OK 4: Non-critical 5:…
1.3.6.1.4.1.674.10892.2.6.1.20.130.4.1.27ColumnphysicalDiskPartNumberread-onlymandatoryThe part number of the disk.
1.3.6.1.4.1.674.10892.2.6.1.20.130.4.1.28ColumnphysicalDiskSASAddressread-onlymandatoryThe SAS address of the physical disk.
1.3.6.1.4.1.674.10892.2.6.1.20.130.4.1.29ColumnphysicalDiskNegotiatedSpeedread-onlymandatoryThe data transfer speed that the disk negotiated while spinning up in Gigbits per second (Gbps). Possible values: 1: The speed could not be determined. 2. 1.5 …
1.3.6.1.4.1.674.10892.2.6.1.20.130.4.1.30ColumnphysicalDiskCapableSpeedread-onlymandatoryThe maximum data transfer speed supported by the disk in Gigbits per second (Gbps). Possible values: 1: The speed could not be determined. 2. 1.5 Gbps 3: 3.0 G…
1.3.6.1.4.1.674.10892.2.6.1.20.130.4.1.31ColumnphysicalDiskSmartAlertIndicationread-onlymandatoryIndicates whether the physical disk has received a predictive failure alert.
1.3.6.1.4.1.674.10892.2.6.1.20.130.4.1.32ColumnphysicalDiskManufactureDayread-onlymandatoryThe day of the week (1=Sunday thru 7=Saturday) on which the physical disk was manufactured.
1.3.6.1.4.1.674.10892.2.6.1.20.130.4.1.33ColumnphysicalDiskManufactureWeekread-onlymandatoryThe week (1 thru 53) in which the physical disk was manufactured.
1.3.6.1.4.1.674.10892.2.6.1.20.130.4.1.34ColumnphysicalDiskManufactureYearread-onlymandatoryThe four digit year in which the physical disk was manufactured.
1.3.6.1.4.1.674.10892.2.6.1.20.130.4.1.35ColumnphysicalDiskMediaTyperead-onlymandatoryThe media type of the physical disk. Possible Values: 1: The media type could not be determined. 2: Hard Disk Drive (HDD). 3: Solid State Device (SSD).
1.3.6.1.4.1.674.10892.2.6.1.20.130.4.1.42ColumnphysicalDiskPowerStateread-onlymandatoryThe power state of the physical disk. Possible Values: 1: Not one of the following. 2: The physical disk is in the spun up state. 3: The physical disk is in th…
1.3.6.1.4.1.674.10892.2.6.1.20.130.4.1.49ColumnphysicalDiskRemainingRatedWriteEnduranceread-onlymandatoryThis property is applicable to SSD media type only. This indicates the wear-out percentage of the SSD. Typically it is a value between 0 to 100. However, if th…
1.3.6.1.4.1.674.10892.2.6.1.20.130.4.1.50ColumnphysicalDiskOperationalStateread-onlymandatoryThe state of the physical disk when there are progressive operations ongoing. Possible values: 1: There is no active operation running. 2: Data from a redundan…
1.3.6.1.4.1.674.10892.2.6.1.20.130.4.1.51ColumnphysicalDiskProgressread-onlymandatoryThe progress percentage of the operation that is being performed on the physical disk. This is applicable only if there is a progressive operations ongoing
1.3.6.1.4.1.674.10892.2.6.1.20.130.4.1.52ColumnphysicalDiskSecurityStatusread-onlymandatoryThe security/encryption status of the physical disk. Possible Values: 1: The physical disk supports encryption. 2: The physical disk does not support encryptio…
1.3.6.1.4.1.674.10892.2.6.1.20.130.4.1.53ColumnphysicalDiskFormFactorread-onlymandatoryThe form factor of the physical disk. Possible values: 1: The form factor could not be determined. 2: 1.8 inch. 3: 2.5 inch. 4: 3.5 inch.
1.3.6.1.4.1.674.10892.2.6.1.20.130.4.1.54ColumnphysicalDiskFQDDread-onlymandatoryThe physical disk's Fully Qualified Device Descriptor (FQDD) as represented in Storage Management.
1.3.6.1.4.1.674.10892.2.6.1.20.130.4.1.55ColumnphysicalDiskDisplayNameread-onlymandatoryThe physical disk's friendly FQDD as represented in Storage Management.
1.3.6.1.4.1.674.10892.2.6.1.20.130.4.1.57ColumnphysicalDiskT10PICapabilityread-onlymandatoryIndicates whether the physical disk supports the T10 PI (Protection Information). These protection fields are known as DIF (Data Integrity Fields). Possible va…
1.3.6.1.4.1.674.10892.2.6.1.20.130.4.1.58ColumnphysicalDiskBlockSizeInBytesread-onlymandatoryThe block size (in bytes) of the physical disk. This is not applicable for NVMe devices. Possible values: 1: 512. 2: 4096
1.3.6.1.4.1.674.10892.2.6.1.20.130.4.1.59ColumnphysicalDiskProtocolVersionread-onlymandatoryApplicable for NVMe devices only. The NVMe protocol version supported by the device.
1.3.6.1.4.1.674.10892.2.6.1.20.130.4.1.60ColumnphysicalDiskPCIeNegotiatedLinkWidthread-onlymandatoryApplicable for NVMe devices only. The PCIe link width negotiated with the host during device initialization.
1.3.6.1.4.1.674.10892.2.6.1.20.130.4.1.61ColumnphysicalDiskPCIeCapableLinkWidthread-onlymandatoryApplicable for NVMe devices only. The PCIe link widths the device is capable of supporting.
1.3.6.1.4.1.674.10892.2.6.1.20.130.4.1.62ColumnphysicalDiskCurrentActiveControllerread-onlymandatoryIndicates the Fully Qualified Device Descriptor (FQDD) of the current active controller.
1.3.6.1.4.1.674.10892.2.6.1.20.130.4.1.63ColumnphysicalDiskFailoverControllerread-onlymandatoryIndicates the Fully Qualified Device Descriptor (FQDD) of the failover controller.
1.3.6.1.4.1.674.10892.2.6.1.20.130.4.1.64ColumnphysicalDiskForeignKeyIdentifierread-onlymandatoryDisplays the encryption key identifier of the physical disk if it is in locked or foreign state.
1.3.6.1.4.1.674.10892.2.6.1.20.130.7TableenclosureFanTablenot-accessiblemandatoryA table of managed fans in the external storage enclosure(s). The number of entries is related to number of fans discovered in the enclosure(s). The maximum nu…
1.3.6.1.4.1.674.10892.2.6.1.20.130.7.1RowenclosureFanTableEntrynot-accessiblemandatoryAn entry in the fan table. A row in this table cannot be created or deleted by SNMP operations on columns of the table.
1.3.6.1.4.1.674.10892.2.6.1.20.130.7.1.1ColumnenclosureFanNumberread-onlymandatoryInstance number of this fan.
1.3.6.1.4.1.674.10892.2.6.1.20.130.7.1.2ColumnenclosureFanNameread-onlymandatoryThe fan's name as represented in Storage Management.
1.3.6.1.4.1.674.10892.2.6.1.20.130.7.1.4ColumnenclosureFanStateread-onlymandatoryThe current state of this fan. Possible states: 1: The current state could not be determined. 2: The fan is operating normally. 3: The fan has encountered a ha…
1.3.6.1.4.1.674.10892.2.6.1.20.130.7.1.11ColumnenclosureFanSpeedread-onlymandatoryIndicates the current relative speed of the fan in RPMs.
1.3.6.1.4.1.674.10892.2.6.1.20.130.7.1.15ColumnenclosureFanComponentStatusread-onlymandatoryThe status of the fan itself without the propagation of any contained component status. Possible values: 1: Other. 2: Unknown. 3: OK. 4: Non-critical . 5: Crit…
1.3.6.1.4.1.674.10892.2.6.1.20.130.7.1.20ColumnenclosureFanFQDDread-onlymandatoryThe fan's Fully Qualified Device Descriptor (FQDD) as represented in Storage Management.
1.3.6.1.4.1.674.10892.2.6.1.20.130.7.1.21ColumnenclosureFanDisplayNameread-onlymandatoryThe fan's friendly FQDD as represented in Storage Management.
1.3.6.1.4.1.674.10892.2.6.1.20.130.9TableenclosurePowerSupplyTablenot-accessiblemandatoryA table of managed Power Supply Units(PSU) in the external storage enclosure(s). The number of entries is related to number of power supply unit(s) discovered …
1.3.6.1.4.1.674.10892.2.6.1.20.130.9.1RowenclosurePowerSupplyTableEntrynot-accessiblemandatoryAn entry in the power supply unit table. A row in this table cannot be created or deleted by SNMP operations on columns of the table.
1.3.6.1.4.1.674.10892.2.6.1.20.130.9.1.1ColumnenclosurePowerSupplyNumberread-onlymandatoryInstance number of this power supply unit.
1.3.6.1.4.1.674.10892.2.6.1.20.130.9.1.2ColumnenclosurePowerSupplyNameread-onlymandatoryThe power supply unit's name as represented in Storage Management.
1.3.6.1.4.1.674.10892.2.6.1.20.130.9.1.4ColumnenclosurePowerSupplyStateread-onlymandatoryThe current state of this power supply unit. Possible states: 1: The current state could not be determined. 2: The power supply unit is operating normally. 3: …
1.3.6.1.4.1.674.10892.2.6.1.20.130.9.1.7ColumnenclosurePowerSupplyPartNumberread-onlymandatoryThe part number of the power supply unit.
1.3.6.1.4.1.674.10892.2.6.1.20.130.9.1.9ColumnenclosurePowerSupplyComponentStatusread-onlymandatoryThe status of the power supply unit itself without the propagation of any contained component status. Possible values: 1: Other. 2: Unknown. 3: OK. 4: Non-crit…
1.3.6.1.4.1.674.10892.2.6.1.20.130.9.1.15ColumnenclosurePowerSupplyFQDDread-onlymandatoryThe power supply unit's Fully Qualified Device Descriptor (FQDD) as represented in Storage Management.
1.3.6.1.4.1.674.10892.2.6.1.20.130.9.1.16ColumnenclosurePowerSupplyDisplayNameread-onlymandatoryThe power supply unit's friendly FQDD as represented in Storage Management.
1.3.6.1.4.1.674.10892.2.6.1.20.130.11TableenclosureTemperatureProbeTablenot-accessiblemandatoryA table of managed temperature probes in the external storage enclosure(s). The number of entries is related to number of temperature probes discovered in the …
1.3.6.1.4.1.674.10892.2.6.1.20.130.11.1RowenclosureTemperatureProbeTableEntrynot-accessiblemandatoryAn entry in the temperature probe table. A row in this table cannot be created or deleted by SNMP operations on columns of the table.
1.3.6.1.4.1.674.10892.2.6.1.20.130.11.1.1ColumnenclosureTemperatureProbeNumberread-onlymandatoryInstance number of this temperature probe.
1.3.6.1.4.1.674.10892.2.6.1.20.130.11.1.2ColumnenclosureTemperatureProbeNameread-onlymandatoryThe temperature probe's name as represented in Storage Management.
1.3.6.1.4.1.674.10892.2.6.1.20.130.11.1.4ColumnenclosureTemperatureProbeStateread-onlymandatoryThe current state of this temperature probe. Possible states: 1: The current state could not be determined. 2: The temperature probe is operating normally. 3: …
1.3.6.1.4.1.674.10892.2.6.1.20.130.11.1.7ColumnenclosureTemperatureProbeMinWarningValueread-onlymandatoryThe minimum temperature that will force the probe into a warning state.
1.3.6.1.4.1.674.10892.2.6.1.20.130.11.1.8ColumnenclosureTemperatureProbeMinCriticalValueread-onlymandatoryThe minimum temperature that will force the probe into a error state.
1.3.6.1.4.1.674.10892.2.6.1.20.130.11.1.9ColumnenclosureTemperatureProbeMaxWarningValueread-onlymandatoryThe maximum temperature that will force the probe into a warning state.
1.3.6.1.4.1.674.10892.2.6.1.20.130.11.1.10ColumnenclosureTemperatureProbeMaxCriticalValueread-onlymandatoryThe maximum temperature that will force the probe into a warning state.
1.3.6.1.4.1.674.10892.2.6.1.20.130.11.1.11ColumnenclosureTemperatureProbeCurValueread-onlymandatoryThe maximum temperature that will force the probe into a warning state.
1.3.6.1.4.1.674.10892.2.6.1.20.130.11.1.13ColumnenclosureTemperatureProbeComponentStatusread-onlymandatoryThe status of the enclosure management module.itself without the propagation of any contained component status. Possible values: 1: Other. 2: Unknown. 3: OK. 4…
1.3.6.1.4.1.674.10892.2.6.1.20.130.11.1.15ColumnenclosureTemperatureProbeFQDDread-onlymandatoryThe temperature probe's Fully Qualified Device Descriptor (FQDD) as represented in Storage Management.
1.3.6.1.4.1.674.10892.2.6.1.20.130.11.1.16ColumnenclosureTemperatureProbeDisplayNameread-onlymandatoryThe temperature probe's friendly FQDD as represented in Storage Management.
1.3.6.1.4.1.674.10892.2.6.1.20.130.13TableenclosureManagementModuleTablenot-accessiblemandatoryA table of managed Enclosure Management Modules (EMM) in the external storage enclosure(s). The number of entries is related to number of enclosure management …
1.3.6.1.4.1.674.10892.2.6.1.20.130.13.1RowenclosureManagementModuleTableEntrynot-accessiblemandatoryAn entry in the enclosure management module table. A row in this table cannot be created or deleted by SNMP operations on columns of the table.
1.3.6.1.4.1.674.10892.2.6.1.20.130.13.1.1ColumnenclosureManagementModuleNumberread-onlymandatoryInstance number of this enclosure management module.
1.3.6.1.4.1.674.10892.2.6.1.20.130.13.1.2ColumnenclosureManagementModuleNameread-onlymandatoryThe enclosure management module's name as represented in Storage Management.
1.3.6.1.4.1.674.10892.2.6.1.20.130.13.1.4ColumnenclosureManagementModuleStateread-onlymandatoryThe current state of this enclosure management module. Possible states: 1: The current state could not be determined. 2: The enclosure management module is ope…
1.3.6.1.4.1.674.10892.2.6.1.20.130.13.1.6ColumnenclosureManagementModulePartNumberread-onlymandatoryThe part number of the enclosure management module.
1.3.6.1.4.1.674.10892.2.6.1.20.130.13.1.8ColumnenclosureManagementModuleFWVersionread-onlymandatoryFirmware version of the enclosure management module.
1.3.6.1.4.1.674.10892.2.6.1.20.130.13.1.11ColumnenclosureManagementModuleComponentStatusread-onlymandatoryThe status of the enclosure management module.itself without the propagation of any contained component status. Possible values: 1: Other. 2: Unknown. 3: OK. 4…
1.3.6.1.4.1.674.10892.2.6.1.20.130.13.1.15ColumnenclosureManagementModuleFQDDread-onlymandatoryThe enclosure management module's Fully Qualified Device Descriptor (FQDD) as represented in Storage Management.
1.3.6.1.4.1.674.10892.2.6.1.20.130.13.1.16ColumnenclosureManagementModuleDisplayNameread-onlymandatoryThe enclosure management module's friendly FQDD as represented in Storage Management.
1.3.6.1.4.1.674.10892.2.6.1.20.130.15TablebatteryTablenot-accessiblemandatoryA table of managed batteries. The number of entries is related to number of Batteries discovered in the system. The maximum number of entries is implementation…
1.3.6.1.4.1.674.10892.2.6.1.20.130.15.1RowbatteryTableEntrynot-accessiblemandatoryAn entry in the battery table. A row in this table cannot be created or deleted by SNMP operations on columns of the table.
1.3.6.1.4.1.674.10892.2.6.1.20.130.15.1.1ColumnbatteryNumberread-onlymandatoryInstance number of this battery entry.
1.3.6.1.4.1.674.10892.2.6.1.20.130.15.1.4ColumnbatteryStateread-onlymandatoryCurrent state of battery. Possible values: 1: The current state could not be determined. 2: The battery is operating normally. 3: The battery has failed and ne…
1.3.6.1.4.1.674.10892.2.6.1.20.130.15.1.6ColumnbatteryComponentStatusread-onlymandatoryThe status of the battery itself without the propagation of any contained component status. Possible values: 1: Other 2: Unknown 3: OK 4: Non-critical 5: Criti…
1.3.6.1.4.1.674.10892.2.6.1.20.130.15.1.10ColumnbatteryPredictedCapacityread-onlyobsoleteThis entry is obsolete. Use the batteryComponentStatus or batteryState instead.
1.3.6.1.4.1.674.10892.2.6.1.20.130.15.1.20ColumnbatteryFQDDread-onlymandatoryThe battery's Fully Qualified Device Descriptor (FQDD) as represented in Storage Management.
1.3.6.1.4.1.674.10892.2.6.1.20.130.15.1.21ColumnbatteryDisplayNameread-onlymandatoryThe battery's friendly FQDD as represented in Storage Management.
1.3.6.1.4.1.674.10892.2.6.1.20.140NodelogicalDevices
1.3.6.1.4.1.674.10892.2.6.1.20.140.1TablevirtualDiskTablenot-accessiblemandatoryA table of managed virtual disks. The number of entries is related to number of virtual disks discovered in the system. The maximum number of entries is implem…
1.3.6.1.4.1.674.10892.2.6.1.20.140.1.1RowvirtualDiskTableEntrynot-accessiblemandatoryAn entry in the virtual disk table. A row in this table cannot be created or deleted by SNMP operations on columns of the table.
1.3.6.1.4.1.674.10892.2.6.1.20.140.1.1.1ColumnvirtualDiskNumberread-onlymandatoryInstance number of this virtual disk entry.
1.3.6.1.4.1.674.10892.2.6.1.20.140.1.1.2ColumnvirtualDiskNameread-onlymandatoryThe virtual disk's label as entered by the user.
1.3.6.1.4.1.674.10892.2.6.1.20.140.1.1.4ColumnvirtualDiskStateread-onlymandatoryThe current state of this virtual disk (which includes any member physical disks.) Possible states: 1: The current state could not be determined. 2: The virtua…
1.3.6.1.4.1.674.10892.2.6.1.20.140.1.1.6ColumnvirtualDiskSizeInMBread-onlymandatoryThe size of the virtual disk in megabytes.
1.3.6.1.4.1.674.10892.2.6.1.20.140.1.1.10ColumnvirtualDiskWritePolicyread-onlymandatoryThe write policy used by the controller for write operations on this virtual disk. Possible values: 1: Write Through. 2: Write Back. 3: Force Write Back.
1.3.6.1.4.1.674.10892.2.6.1.20.140.1.1.11ColumnvirtualDiskReadPolicyread-onlymandatoryThe read policy used by the controller for read operations on this virtual disk. Possible values: 1: No Read Ahead. 2: Read Ahead. 3: Adaptive Read Ahead.
1.3.6.1.4.1.674.10892.2.6.1.20.140.1.1.13ColumnvirtualDiskLayoutread-onlymandatoryThe virtual disk's RAID type. Possible values: 1: Not one of the following 2: RAID-0 3: RAID-1 4: RAID-5 5: RAID-6 6: RAID-10 7: RAID-50 8: RAID-60 9: Concaten…
1.3.6.1.4.1.674.10892.2.6.1.20.140.1.1.14ColumnvirtualDiskStripeSizeread-onlymandatoryThe stripe size of this virtual disk. Possible values: 1: Not one of the following 2: Default. 3: 512 bytes 4: 1 kB, 5: 2 kB, 6: 4 kB, 7: 8 kB, 8: 16 kB, 9: 32…
1.3.6.1.4.1.674.10892.2.6.1.20.140.1.1.20ColumnvirtualDiskComponentStatusread-onlymandatoryThe status of the virtual disk itself without the propagation of any contained component status. Possible values: 1: Other. 2: Unknown. 3: OK. 4: Non-critical …
1.3.6.1.4.1.674.10892.2.6.1.20.140.1.1.23ColumnvirtualDiskBadBlocksDetectedread-onlymandatoryIndicates whether the virtual disk has bad blocks.
1.3.6.1.4.1.674.10892.2.6.1.20.140.1.1.24ColumnvirtualDiskSecuredread-onlymandatoryIndicates whether the virtual disk is secured or not.
1.3.6.1.4.1.674.10892.2.6.1.20.140.1.1.25ColumnvirtualDiskIsCacheCaderead-onlymandatoryIndicates whether the virtual disk is being used as a secondary cache by the controller.
1.3.6.1.4.1.674.10892.2.6.1.20.140.1.1.26ColumnvirtualDiskDiskCachePolicyread-onlymandatoryThe cache policy of the physical disks that are part of this virtual disk Possible values: 1: Enabled. 2: Disabled. 3: Default.
1.3.6.1.4.1.674.10892.2.6.1.20.140.1.1.30ColumnvirtualDiskOperationalStateread-onlymandatoryThe state of the virtual disk when there are progressive operations ongoing. Possible values: 1: There is no active operation running. 2: The virtual disk conf…
1.3.6.1.4.1.674.10892.2.6.1.20.140.1.1.31ColumnvirtualDiskProgressread-onlymandatoryThe progress percentage of the operation that is being performed on the virtual disk. This is applicable only if there is a progressive operations ongoing
1.3.6.1.4.1.674.10892.2.6.1.20.140.1.1.32ColumnvirtualDiskAvailableProtocolsread-onlymandatoryList of protocols support by physical disks part of this virtual disk. For e.g. SAS for Serial Attached SCSI or SATA for Serial Advanced Technology Attachment.
1.3.6.1.4.1.674.10892.2.6.1.20.140.1.1.33ColumnvirtualDiskMediaTyperead-onlymandatoryList of media types of the physical disks part of this virtual disk. For e.g. HDD for Hard Disk Drive or SSD for Solid State Device.
1.3.6.1.4.1.674.10892.2.6.1.20.140.1.1.34ColumnvirtualDiskRemainingRedundancyread-onlymandatoryThe number of physical disks which can be lost before the virtual disk loses its redundancy.
1.3.6.1.4.1.674.10892.2.6.1.20.140.1.1.35ColumnvirtualDiskFQDDread-onlymandatoryThe virtual disk's Fully Qualified Device Descriptor (FQDD) as represented in Storage Management.
1.3.6.1.4.1.674.10892.2.6.1.20.140.1.1.36ColumnvirtualDiskDisplayNameread-onlymandatoryThe virtual disk's friendly FQDD as represented in Storage Management.
1.3.6.1.4.1.674.10892.2.6.1.20.140.1.1.37ColumnvirtualDiskT10PIStatusread-onlymandatoryIndicates whether the virtual disk supports the T10 PI (Protection Information). These protection fields are known as DIF (Data Integrity Fields). Possible val…
1.3.6.1.4.1.674.10892.2.6.1.20.140.1.1.38ColumnvirtualDiskBlockSizeInBytesread-onlymandatoryThe block size (in bytes) of the physical disk part of the virtual disk. Possible values: 1: 512. 2: 4096
1.3.6.1.4.1.674.10892.2.6.1.20.140.1.1.39ColumnvirtualDiskAdapter1AccessPolicyread-onlymandatoryIndicates the access policy of the virtual disk with the virtual adapters. Possible values: 1: No Access. 2: Full Access
1.3.6.1.4.1.674.10892.2.6.1.20.140.1.1.40ColumnvirtualDiskAdapter2AccessPolicyread-onlymandatoryIndicates the access policy of the virtual disk with the virtual adapters. Possible values: 1: No Access. 2: Full Access
1.3.6.1.4.1.674.10892.2.6.1.20.140.1.1.41ColumnvirtualDiskAdapter3AccessPolicyread-onlymandatoryIndicates the access policy of the virtual disk with the virtual adapters. Possible values: 1: No Access. 2: Full Access
1.3.6.1.4.1.674.10892.2.6.1.20.140.1.1.42ColumnvirtualDiskAdapter4AccessPolicyread-onlymandatoryIndicates the access policy of the virtual disk with the virtual adapters. Possible values: 1: No Access. 2: Full Access
1.3.6.1.4.1.674.10892.2.6.1.20.140.1.1.43ColumnvirtualDiskCurrentActiveControllerread-onlymandatoryIndicates the Fully Qualified Device Descriptor (FQDD) of the current active controller.
1.3.6.1.4.1.674.10892.2.6.1.20.140.1.1.44ColumnvirtualDiskFailoverControllerread-onlymandatoryIndicates the Fully Qualified Device Descriptor (FQDD) of the failover controller.
1.3.6.1.4.1.674.10892.2.20NodedrsCMCAlertGroup
1.3.6.1.4.1.674.10892.2.20.10NodedrsChassisAlertVariables
1.3.6.1.4.1.674.10892.2.20.10.1ScalardrsCASubSystemread-onlymandatory0020.0010.0001 This attribute defines the Sub-System Name of the CMC Alert
1.3.6.1.4.1.674.10892.2.20.10.2ScalardrsCASSCurrStatusread-onlymandatory0020.0010.0002 This attribute defines the Current Status of the Alerting Sub-System
1.3.6.1.4.1.674.10892.2.20.10.3ScalardrsCASSPrevStatusread-onlymandatory0020.0010.0003 This attribute defines the Previous Status of the Alerting Sub-System
1.3.6.1.4.1.674.10892.2.20.10.4ScalardrsCASSChangeTimeread-onlymandatory0020.0010.0004 This attribute defines the Timestamp of Most Recent Change of the Alerting Sub-System
1.3.6.1.4.1.674.10892.2.20.10.5ScalardrsCAMessageread-onlymandatory0020.0010.0005 This attribute defines the CSSD message of the CMC Alert
1.3.6.1.4.1.674.10892.2.21NodedrsCMCAlert2Group
1.3.6.1.4.1.674.10892.2.21.10NodedrsChassisAlert2Variables
1.3.6.1.4.1.674.10892.2.21.10.1ScalardrsCA2MessageIDread-onlymandatoryMessage ID of the alert.
1.3.6.1.4.1.674.10892.2.21.10.2ScalardrsCA2Messageread-onlymandatoryMessage describing the alert.
1.3.6.1.4.1.674.10892.2.21.10.3ScalardrsCA2MessageArgsread-onlymandatoryConcatenated set of strings representing any message arguments that were used to construct the alert message. Each message argument string is enclosed in doubl…
1.3.6.1.4.1.674.10892.2.21.10.4ScalardrsCA2AlertStatusread-onlymandatoryStatus of the alert.
1.3.6.1.4.1.674.10892.2.21.10.5ScalardrsCA2FQDDread-onlymandatoryFully qualified device descriptor of device causing the alert.
1.3.6.1.4.1.674.10892.2.21.2153Nodealert2FanFailureFan failure.
1.3.6.1.4.1.674.10892.2.21.2154Nodealert2FanWarningFan warning.
1.3.6.1.4.1.674.10892.2.21.2155Nodealert2FanInformationFan information.
1.3.6.1.4.1.674.10892.2.21.2161Nodealert2TemperatureProbeFailureTemperature sensor has detected a failure value.
1.3.6.1.4.1.674.10892.2.21.2162Nodealert2TemperatureProbeWarningTemperature sensor has detected a warning value.
1.3.6.1.4.1.674.10892.2.21.2163Nodealert2TemperatureProbeNormalTemperature sensor value is within range.
1.3.6.1.4.1.674.10892.2.21.2169Nodealert2VoltageProbeFailureVoltage sensor has detected a failure value.
1.3.6.1.4.1.674.10892.2.21.2170Nodealert2VoltageProbeWarningVoltage sensor has detected a warning value.
1.3.6.1.4.1.674.10892.2.21.2171Nodealert2VoltageProbeNormalVoltage sensor reading is within range.
1.3.6.1.4.1.674.10892.2.21.2177Nodealert2AmperageProbeFailureCurrent sensor has detected a failure value.
1.3.6.1.4.1.674.10892.2.21.2178Nodealert2AmperageProbeWarningCurrent sensor has detected a warning value.
1.3.6.1.4.1.674.10892.2.21.2179Nodealert2AmperageProbeNormalCurrent sensor reading is within range.
1.3.6.1.4.1.674.10892.2.21.2185Nodealert2PowerSupplyFailurePower supply has detected a failure.
1.3.6.1.4.1.674.10892.2.21.2186Nodealert2PowerSupplyWarningPower supply has detected a warning.
1.3.6.1.4.1.674.10892.2.21.2187Nodealert2PowerSupplyNormalPower supply has returned to normal.
1.3.6.1.4.1.674.10892.2.21.2225Nodealert2BatteryFailureBattery has failed or battery is absent.
1.3.6.1.4.1.674.10892.2.21.2226Nodealert2BatteryWarningBattery is low.
1.3.6.1.4.1.674.10892.2.21.2227Nodealert2BatteryNormalBattery state has returned to normal; or battery presence had been detected.
1.3.6.1.4.1.674.10892.2.21.2249Nodealert2LinkStatusFailureLink status failure or critical event.
1.3.6.1.4.1.674.10892.2.21.2250Nodealert2LinkStatusWarningLink status warning.
1.3.6.1.4.1.674.10892.2.21.2251Nodealert2LinkStatusInformationLink status information.
1.3.6.1.4.1.674.10892.2.21.2273Nodealert2PowerUsageFailurePower usage failure.
1.3.6.1.4.1.674.10892.2.21.2274Nodealert2PowerUsageWarningPower usage warning.
1.3.6.1.4.1.674.10892.2.21.2275Nodealert2PowerUsageInformationPower usage information.
1.3.6.1.4.1.674.10892.2.21.2329Nodealert2HardwareConfigurationFailureHardware configuration failure or critical event.
1.3.6.1.4.1.674.10892.2.21.2330Nodealert2HardwareConfigurationWarningHardware configuration warning.
1.3.6.1.4.1.674.10892.2.21.2331Nodealert2HardwareConfigurationInformationHardware configuration information.
1.3.6.1.4.1.674.10892.2.21.2337Nodealert2SoftwareConfigurationFailureSoftware configuration failure.
1.3.6.1.4.1.674.10892.2.21.2338Nodealert2SoftwareConfigurationWarningSoftware configuration warning.
1.3.6.1.4.1.674.10892.2.21.2339Nodealert2SoftwareConfigurationInformationSoftware configuration information.
1.3.6.1.4.1.674.10892.2.21.2377Nodealert2SystemEventLogFailureSystem Event Log failure or critical event.
1.3.6.1.4.1.674.10892.2.21.2378Nodealert2SystemEventLogWarningSystem Event Log warning.
1.3.6.1.4.1.674.10892.2.21.2379Nodealert2SystemEventLogInformationSystem Event Log information.
1.3.6.1.4.1.674.10892.2.21.2385Nodealert2SecurityFailureSecurity failure or critical event.
1.3.6.1.4.1.674.10892.2.21.2386Nodealert2SecurityWarningSecurity warning.
1.3.6.1.4.1.674.10892.2.21.2387Nodealert2SecurityInformationSecurity information.
1.3.6.1.4.1.674.10892.2.21.2393Nodealert2CableFailureCable failure.
1.3.6.1.4.1.674.10892.2.21.2417Nodealert2PCIDeviceFailurePCI device failure or critical event.
1.3.6.1.4.1.674.10892.2.21.2418Nodealert2PCIDeviceWarningPCI device warning.
1.3.6.1.4.1.674.10892.2.21.2419Nodealert2PCIDeviceInformationPCI device information.
1.3.6.1.4.1.674.10892.2.21.2465Nodealert2PowerSupplyAbsentPower supply is absent.
1.3.6.1.4.1.674.10892.2.21.2473Nodealert2RedundancyLostRedundancy is lost.
1.3.6.1.4.1.674.10892.2.21.2474Nodealert2RedundancyDegradedRedundancy is degraded.
1.3.6.1.4.1.674.10892.2.21.2475Nodealert2RedundancyInformationRedundancy information.
1.3.6.1.4.1.674.10892.2.21.2545Nodealert2CMCFailureChassis Management Controller detected an error.
1.3.6.1.4.1.674.10892.2.21.2546Nodealert2CMCWarningChassis Management Controller detected a warning.
1.3.6.1.4.1.674.10892.2.21.2553Nodealert2IOVirtualizationFailureIO Virtualization failure or critical event.
1.3.6.1.4.1.674.10892.2.21.2554Nodealert2IOVirtualizationWarningIO Virtualization warning.
1.3.6.1.4.1.674.10892.2.21.2555Nodealert2IOVirtualizationInformationIO Virtualization information.
1.3.6.1.4.1.674.10892.2.21.4177Nodealert2StorageManagementFailureStorage Management has detected a device independent error condition. There is no global status change associated with this trap.
1.3.6.1.4.1.674.10892.2.21.4178Nodealert2StorageManagementWarningStorage Management has detected a device independent warning condition. There is no global status change associated with this trap.
1.3.6.1.4.1.674.10892.2.21.4179Nodealert2StorageManagementInformationStorage Management information. There is no global status change associated with this trap.
1.3.6.1.4.1.674.10892.2.21.4201Nodealert2StorageFanFailureStorage Fan failure.
1.3.6.1.4.1.674.10892.2.21.4202Nodealert2StorageFanWarningStorage Fan warning.
1.3.6.1.4.1.674.10892.2.21.4203Nodealert2StorageFanInformationStorage Fan information.
1.3.6.1.4.1.674.10892.2.21.4209Nodealert2StorageTemperatureProbeFailureStorage Temperature probe failure.
1.3.6.1.4.1.674.10892.2.21.4210Nodealert2StorageTemperatureProbeWarningStorage Temperature probe warning.
1.3.6.1.4.1.674.10892.2.21.4211Nodealert2StorageTemperatureProbeInformationStorage Temperature probe information.
1.3.6.1.4.1.674.10892.2.21.4233Nodealert2StoragePowerSupplyFailureStorage Power supply failure.
1.3.6.1.4.1.674.10892.2.21.4234Nodealert2StoragePowerSupplyWarningStorage Power supply warning.
1.3.6.1.4.1.674.10892.2.21.4235Nodealert2StoragePowerSupplyInformationStorage Power supply information.
1.3.6.1.4.1.674.10892.2.21.4273Nodealert2StorageBatteryFailureStorage Battery failure.
1.3.6.1.4.1.674.10892.2.21.4274Nodealert2StorageBatteryWarningStorage Battery warning.
1.3.6.1.4.1.674.10892.2.21.4275Nodealert2StorageBatteryInformationStorage Battery information.
1.3.6.1.4.1.674.10892.2.21.4329Nodealert2StorageControllerFailureStorage Controller failure.
1.3.6.1.4.1.674.10892.2.21.4330Nodealert2StorageControllerWarningStorage Controller warning.
1.3.6.1.4.1.674.10892.2.21.4331Nodealert2StorageControllerInformationStorage Controller information.
1.3.6.1.4.1.674.10892.2.21.4337Nodealert2StorageEnclosureFailureStorage Enclosure failure.
1.3.6.1.4.1.674.10892.2.21.4338Nodealert2StorageEnclosureWarningStorage Enclosure warning.
1.3.6.1.4.1.674.10892.2.21.4339Nodealert2StorageEnclosureInformationStorage Enclosure information.
1.3.6.1.4.1.674.10892.2.21.4345Nodealert2StoragePhysicalDiskFailureStorage Physical disk failure.
1.3.6.1.4.1.674.10892.2.21.4346Nodealert2StoragePhysicalDiskWarningStorage Physical disk warning.
1.3.6.1.4.1.674.10892.2.21.4347Nodealert2StoragePhysicalDiskInformationStorage Physical disk information.
1.3.6.1.4.1.674.10892.2.21.4353Nodealert2StorageVirtualDiskFailureStorage Virtual disk failure.
1.3.6.1.4.1.674.10892.2.21.4354Nodealert2StorageVirtualDiskWarningStorage Virtual disk warning.
1.3.6.1.4.1.674.10892.2.21.4355Nodealert2StorageVirtualDiskInformationStorage Virtual disk information.
1.3.6.1.4.1.674.10892.2.21.4433Nodealert2StorageSecurityFailureStorage Security failure or critical event.
1.3.6.1.4.1.674.10892.2.21.4434Nodealert2StorageSecurityWarningStorage Security warning.
1.3.6.1.4.1.674.10892.2.21.4435Nodealert2StorageSecurityInformationStorage Security information.
1.3.6.1.4.1.674.10892.2.21.6314Nodealert2SoftwareChangeUpdateWarningSoftware change update warning.
1.3.6.1.4.1.674.10892.2.21.8305Nodealert2IOMTemperatureExceededI/O Module <iom slot name> temperature exceeded operating range.
1.3.6.1.4.1.674.10892.2.21.8306Nodealert2Unable2ReadTemperatureSensorsUnable to read planar board temperature sensors. The cooling has been increased to safeguard the system.
1.3.6.1.4.1.674.10892.2.21.8329Nodealert2PowerSupplyAuditFailurePower Supply audit failure or critical event.
1.3.6.1.4.1.674.10892.2.21.8330Nodealert2PowerSupplyAuditWarningPower Supply audit warning.
1.3.6.1.4.1.674.10892.2.21.8331Nodealert2PowerSupplyRedundancyPolicyChangedPSU redundancy policy changed.
1.3.6.1.4.1.674.10892.2.21.8361Nodealert2SoftwareChangeAuditFailureSoftware change audit failure or critical event.
1.3.6.1.4.1.674.10892.2.21.8417Nodealert2PowerUsageAuditFailurePower usage audit failure or critical event.
1.3.6.1.4.1.674.10892.2.21.8418Nodealert2PowerUsageAuditWarningPower usage audit warning.
1.3.6.1.4.1.674.10892.2.21.8419Nodealert2PowerUsageAuditInformationPower usage audit information.
1.3.6.1.4.1.674.10892.2.21.8513Nodealert2LicenseFailureLicense failure.
1.3.6.1.4.1.674.10892.2.21.8514Nodealert2LicenseWarningLicense warning.
1.3.6.1.4.1.674.10892.2.21.8515Nodealert2LicenseInformationLicense information.
1.3.6.1.4.1.674.10892.2.21.8562Nodealert2PCIDeviceAuditWarningPCI device audit warning.
1.3.6.1.4.1.674.10892.2.21.8689Nodealert2CMCAuditFailureChassis Management Controller audit failure or critical event.
1.3.6.1.4.1.674.10892.2.21.8690Nodealert2CMCAuditWarningChassis Management Controller audit warning.
1.3.6.1.4.1.674.10892.2.21.8691Nodealert2CMCAuditInformationChassis Management Controller audit information.
1.3.6.1.4.1.674.10892.2.21.8698Nodealert2IOVirtualizationAuditWarningIO Virtualization audit warning.
1.3.6.1.4.1.674.10892.2.21.10395Nodealert2CMCTestTrapTest trap generated by CMC in response to a user request.
1.3.6.1.4.1.674.10892.2.21.10529Nodealert2SWCConfigurationFailureSoftware configuration failure.
1.3.6.1.4.1.674.10892.2.21.10530Nodealert2SWCConfigurationWarningSoftware configuration warning.
1.3.6.1.4.1.674.10892.2.21.10611Nodealert2PCIDeviceConfigurationInformationPCI device configuration information.
1.3.6.1.4.1.674.10892.2.21.10746Nodealert2IOVConfigurationWarningIO Virtualization configuration warning.
1.3.6.1.4.1.674.10892.2.21.10747Nodealert2IOVConfigurationInformationIO Virtualization configuration information.
1.3.6.1.4.1.674.10892.2.1001NodealertDrscTestTrapEventThe RAC generated a test trap event in response to a user request.
1.3.6.1.4.1.674.10892.2.1002NodealertDrscAuthErrorThe RAC Authentication Failures during a time period have Exceeded a Threshold.
1.3.6.1.4.1.674.10892.2.1003NodealertDrscLostESMThe RAC cannot communicate with the baseboard management controller (ESM).
1.3.6.1.4.1.674.10892.2.1004NodealertDrscFoundESMThe RAC is communicating normally with the baseboard management controller (ESM).
1.3.6.1.4.1.674.10892.2.1005NodealertDrscPowerOffThe RAC has detected a System power state change to powered-off.
1.3.6.1.4.1.674.10892.2.1006NodealertDrscPowerOnThe RAC has detected a system power state change to powered-on.
1.3.6.1.4.1.674.10892.2.1007NodealertDrscWatchdogExpiredThe RAC has detected that the system watchdog has expired indicating a system hang.
1.3.6.1.4.1.674.10892.2.1008NodealertDrscBattLowThe RAC Battery charge is below 25% indicating that the battery may only be able to power the DRSC for 8-10 minutes.
1.3.6.1.4.1.674.10892.2.1009NodealertDrscTempNormalThe RAC Temperature probe has retured to a normal value.
1.3.6.1.4.1.674.10892.2.1010NodealertDrscTempWarningThe RAC Temperature probe has detected a Warning value.
1.3.6.1.4.1.674.10892.2.1011NodealertDrscTempCriticalThe RAC Temperature probe has detected a failure (or critical) value.
1.3.6.1.4.1.674.10892.2.1012NodealertDrscVoltNormalThe RAC voltage has returned to a normal value.
1.3.6.1.4.1.674.10892.2.1013NodealertDrscVoltWarningThe RAC voltage probe has detected a warning value.
1.3.6.1.4.1.674.10892.2.1014NodealertDrscVoltCriticalThe RAC voltage probe has detected a failure (or critical) value.
1.3.6.1.4.1.674.10892.2.1015NodealertDrscSELWarningThe RAC has detected a new event in the System Event Log with Severity: Warning.
1.3.6.1.4.1.674.10892.2.1016NodealertDrscSELCriticalThe RAC has detected a new event in the System Event Log with Severity: Critical.
1.3.6.1.4.1.674.10892.2.1017NodealertDrscSEL80percentFullThe RAC has detected that the System Event Log is 80% full.
1.3.6.1.4.1.674.10892.2.1018NodealertDrscSEL90percentFullThe RAC has detected that the System Event Log is 90% full.
1.3.6.1.4.1.674.10892.2.1019NodealertDrscSEL100percentFullThe RAC has detected that the System Event Log is 100% full.
1.3.6.1.4.1.674.10892.2.1020NodealertDrscSELNormalThe RAC has detected a new event in the System Event Log with Severity: Normal.
1.3.6.1.4.1.674.10892.2.2000NodealertCMCTestTrapThe CMC has generated a test trap
1.3.6.1.4.1.674.10892.2.2002NodealertCMCNormalTrapThe CMC reported a return-to-normal or informational event.
1.3.6.1.4.1.674.10892.2.2003NodealertCMCWarningTrapThe CMC reported a warning event.
1.3.6.1.4.1.674.10892.2.2004NodealertCMCCriticalTrapThe CMC reported a critical event.
1.3.6.1.4.1.674.10892.2.2005NodealertCMCNonRecoverableTrapThe CMC reported a catastrophic event.
1.3.6.1.4.1.674.10892.2.5000NodedrsAlertGroup
1.3.6.1.4.1.674.10892.2.5000.10NodedrsAlertVariables
1.3.6.1.4.1.674.10892.2.5000.10.1ScalardrsAlertSystemread-onlymandatory5000.0010.0001 Name of the system generating the alert.
1.3.6.1.4.1.674.10892.2.5000.10.2ScalardrsAlertTableIndexOIDread-onlymandatory5000.0010.0002 0.0
1.3.6.1.4.1.674.10892.2.5000.10.3ScalardrsAlertMessageread-onlymandatory5000.0010.0003 Message describing the alert.
1.3.6.1.4.1.674.10892.2.5000.10.4ScalardrsAlertCurrentStatusread-onlymandatory5000.0010.0004 Current status of object causing the alert.
1.3.6.1.4.1.674.10892.2.5000.10.5ScalardrsAlertPreviousStatusread-onlymandatory5000.0010.0005 Previous status of object causing the alert.
1.3.6.1.4.1.674.10892.2.5000.10.6ScalardrsAlertDataread-onlymandatory5000.0010.0006 Alert data.