DELL-RAC-MIB
265 objects
No module-level DESCRIPTION found.
Imported Objects
| RFC-1212 | OBJECT-TYPE |
| RFC-1215 | TRAP-TYPE |
| RFC1155-SMI | enterprises TimeTicks |
| RFC1213-MIB | DisplayString |
| OID | Name | Access | Status | Description |
|---|---|---|---|---|
| 1.3.6.1.4.1.674 | Nodedell | |||
| 1.3.6.1.4.1.674.10892 | Nodeserver3 | |||
| 1.3.6.1.4.1.674.10892.2 | NodedrsOutofBandGroup | |||
| 1.3.6.1.4.1.674.10892.2.1 | NodedrsInformationGroup | |||
| 1.3.6.1.4.1.674.10892.2.1.1 | NodedrsProductInfoGroup | |||
| 1.3.6.1.4.1.674.10892.2.1.1.1 | ScalardrsProductName | read-only | mandatory | 0001.0001.0001 This attribute defines the product name of a chassis management controller. |
| 1.3.6.1.4.1.674.10892.2.1.1.2 | ScalardrsProductShortName | read-only | mandatory | 0001.0001.0002 This attribute defines the short product name of a chassis management controller. |
| 1.3.6.1.4.1.674.10892.2.1.1.3 | ScalardrsProductDescription | read-only | mandatory | 0001.0001.0003 This attribute defines the product description of a chassis management controller. |
| 1.3.6.1.4.1.674.10892.2.1.1.4 | ScalardrsProductManufacturer | read-only | mandatory | 0001.0001.0004 This attribute defines the product manufacturer of a chassis management controller. |
| 1.3.6.1.4.1.674.10892.2.1.1.5 | ScalardrsProductVersion | read-only | mandatory | 0001.0001.0005 This attribute defines the product version of a chassis management controller. |
| 1.3.6.1.4.1.674.10892.2.1.1.6 | ScalardrsChassisServiceTag | read-only | mandatory | 0001.0001.0007 This attribute defines the Service Tag of the chassis. |
| 1.3.6.1.4.1.674.10892.2.1.1.7 | ScalardrsProductURL | read-only | mandatory | 0001.0001.0006 This attribute defines the out-of-band UI URL of a chassis management controller. |
| 1.3.6.1.4.1.674.10892.2.1.1.8 | ScalardrsProductChassisAssetTag | read-only | mandatory | 0001.0001.0008 This attribute defines the Asset Tag of the chassis. |
| 1.3.6.1.4.1.674.10892.2.1.1.9 | ScalardrsProductChassisLocation | read-only | mandatory | 0001.0001.0009 This attribute defines the location of the chassis. |
| 1.3.6.1.4.1.674.10892.2.1.1.10 | ScalardrsProductChassisName | read-only | mandatory | 0001.0001.0010 This attribute defines the name of the chassis. |
| 1.3.6.1.4.1.674.10892.2.1.1.11 | ScalardrsSystemServiceTag | read-only | mandatory | 0001.0001.0011 This attribute defines the service tag of a system. |
| 1.3.6.1.4.1.674.10892.2.1.1.12 | ScalardrsProductSystemAssetTag | read-only | mandatory | 0001.0001.0012 This attribute defines the asset tag of a system. |
| 1.3.6.1.4.1.674.10892.2.1.1.13 | ScalardrsProductSystemSlot | read-only | mandatory | 0001.0001.0013 This attribute defines the slot number of a CMC. |
| 1.3.6.1.4.1.674.10892.2.1.1.14 | ScalardrsProductType | read-only | mandatory | 0001.0001.0014 This attribute defines type of a remote access card |
| 1.3.6.1.4.1.674.10892.2.1.1.15 | ScalardrsProductChassisDataCenter | read-only | mandatory | 0001.0001.0015 This attribute defines the Data Center locator of the chassis. |
| 1.3.6.1.4.1.674.10892.2.1.1.16 | ScalardrsProductChassisAisle | read-only | mandatory | 0001.0001.0016 This attribute defines the Aisle locator of the chassis. |
| 1.3.6.1.4.1.674.10892.2.1.1.17 | ScalardrsProductChassisRack | read-only | mandatory | 0001.0001.0017 This attribute defines the Rack locator of the chassis. |
| 1.3.6.1.4.1.674.10892.2.1.1.18 | ScalardrsProductChassisRackSlot | read-only | mandatory | 0001.0001.0018 This attribute defines the Rack Slot locator of the chassis. |
| 1.3.6.1.4.1.674.10892.2.1.1.19 | ScalardrsProductChassisModel | read-only | mandatory | 0001.0001.0019 This attribute defines the Model of the chassis. |
| 1.3.6.1.4.1.674.10892.2.1.1.20 | ScalardrsProductChassisExpressServiceCode | read-only | mandatory | 0001.0001.0020 This attribute defines the Express Service Code of the chassis. |
| 1.3.6.1.4.1.674.10892.2.1.1.21 | ScalardrsProductChassisSystemID | read-only | mandatory | 0001.0001.0021 This attribute defines the System ID of the chassis. |
| 1.3.6.1.4.1.674.10892.2.1.1.22 | ScalardrsProductChassisSize | read-only | mandatory | 0001.0001.0022 This attribute defines the size of the chassis in rack units (U). A U is a standard unit of measure for the height of a rack or rack-mountable c… |
| 1.3.6.1.4.1.674.10892.2.1.2 | NodedrsFirmwareGroup | |||
| 1.3.6.1.4.1.674.10892.2.1.2.1 | ScalardrsFirmwareVersion | read-only | mandatory | 0001.0002.0001 This attribute defines the firmware version of chassis management controller 1. |
| 1.3.6.1.4.1.674.10892.2.1.2.2 | ScalardrsiKVMFirmwareVersion | read-only | mandatory | 0001.0002.0002 This attribute defines the firmware version of the iKVM. |
| 1.3.6.1.4.1.674.10892.2.1.2.3 | ScalardrsFirmwareVersion2 | read-only | mandatory | 0001.0002.0003 This attribute defines the firmware version of chassis management controller 2. |
| 1.3.6.1.4.1.674.10892.2.2 | NodedrsStatusGroup | |||
| 1.3.6.1.4.1.674.10892.2.2.1 | ScalardrsGlobalSystemStatus | read-only | mandatory | 0002.0001.0001 This attribute defines the overall chassis status being monitored by the chassis management card. |
| 1.3.6.1.4.1.674.10892.2.3 | NodedrsChassisStatusGroup | |||
| 1.3.6.1.4.1.674.10892.2.3.1 | NodedrsStatusNowGroup | |||
| 1.3.6.1.4.1.674.10892.2.3.1.1 | ScalardrsGlobalCurrStatus | read-only | mandatory | 0003.0001.0001 This attribute defines the overall chassis status being monitored by the chassis management card. |
| 1.3.6.1.4.1.674.10892.2.3.1.2 | ScalardrsIOMCurrStatus | read-only | mandatory | 0003.0001.0002 This attribute defines the IOM subsystem status being monitored by the chassis management card. |
| 1.3.6.1.4.1.674.10892.2.3.1.3 | ScalardrsKVMCurrStatus | read-only | mandatory | 0003.0001.0003 This attribute defines the iKVM subsystem health status being monitored by the chassis management card. |
| 1.3.6.1.4.1.674.10892.2.3.1.4 | ScalardrsRedCurrStatus | read-only | mandatory | 0003.0001.0004 This attribute defines the Redundancy status being monitored by the chassis management card. |
| 1.3.6.1.4.1.674.10892.2.3.1.5 | ScalardrsPowerCurrStatus | read-only | mandatory | 0003.0001.0005 This attribute defines the power subsystem health status being monitored by the chassis management card. |
| 1.3.6.1.4.1.674.10892.2.3.1.6 | ScalardrsFanCurrStatus | read-only | mandatory | 0003.0001.0006 This attribute defines the Fan subsystem health status being monitored by the chassis management card. |
| 1.3.6.1.4.1.674.10892.2.3.1.7 | ScalardrsBladeCurrStatus | read-only | mandatory | 0003.0001.0007 This attribute defines the Blade subsystem health status being monitored by the chassis management card. |
| 1.3.6.1.4.1.674.10892.2.3.1.8 | ScalardrsTempCurrStatus | read-only | mandatory | 0003.0001.0008 This attribute defines the Temp Sensor subsystem health status being monitored by the chassis management card. |
| 1.3.6.1.4.1.674.10892.2.3.1.9 | ScalardrsCMCCurrStatus | read-only | mandatory | 0003.0001.0009 This attribute defines the CMC health status being monitored by the chassis management card. |
| 1.3.6.1.4.1.674.10892.2.3.1.10 | ScalardrsChassisFrontPanelAmbientTemperature | read-only | mandatory | 0003.0001.0010 This attribute defines the ambient temperature reading (in degrees Celsius) for the chassis front panel controller. |
| 1.3.6.1.4.1.674.10892.2.3.1.11 | ScalardrsCMCAmbientTemperature | read-only | mandatory | 0003.0001.0011 This attribute defines the ambient temperature reading (in degrees Celsius) for the chassis management card. |
| 1.3.6.1.4.1.674.10892.2.3.1.12 | ScalardrsCMCProcessorTemperature | read-only | mandatory | 0003.0001.0012 This attribute defines the temperature reading (in degrees Celsius) for the chassis management card processor. |
| 1.3.6.1.4.1.674.10892.2.3.2 | NodedrsStatusPrevGroup | |||
| 1.3.6.1.4.1.674.10892.2.3.2.1 | ScalardrsGlobalPrevStatus | read-only | mandatory | 0003.0002.0001 This attribute defines the previous chassis status recorded by the chassis management card. |
| 1.3.6.1.4.1.674.10892.2.3.2.2 | ScalardrsIOMPrevStatus | read-only | mandatory | 0003.0002.0002 This attribute defines the previous IOM subsystem status recorded by the chassis management card. |
| 1.3.6.1.4.1.674.10892.2.3.2.3 | ScalardrsKVMPrevStatus | read-only | mandatory | 0003.0002.0003 This attribute defines the previous iKVM subsystem health status recorded by the chassis management card. |
| 1.3.6.1.4.1.674.10892.2.3.2.4 | ScalardrsRedPrevStatus | read-only | mandatory | 0003.0002.0004 This attribute defines the previous Redundancy status recorded by the chassis management card. |
| 1.3.6.1.4.1.674.10892.2.3.2.5 | ScalardrsPowerPrevStatus | read-only | mandatory | 0003.0002.0005 This attribute defines the previous power subsystem health status recorded by the chassis management card. |
| 1.3.6.1.4.1.674.10892.2.3.2.6 | ScalardrsFanPrevStatus | read-only | mandatory | 0003.0002.0006 This attribute defines the previous Fan health status being monitored by the chassis management card. |
| 1.3.6.1.4.1.674.10892.2.3.2.7 | ScalardrsBladePrevStatus | read-only | mandatory | 0003.0002.0007 This attribute defines the previous Blade subsystem health status recorded by the chassis management card. |
| 1.3.6.1.4.1.674.10892.2.3.2.8 | ScalardrsTempPrevStatus | read-only | mandatory | 0003.0001.0008 This attribute defines the Temp Sensor health status being monitored by the chassis management card. |
| 1.3.6.1.4.1.674.10892.2.3.2.9 | ScalardrsCMCPrevStatus | read-only | mandatory | 0003.0001.0009 This attribute defines the CMC health status being monitored by the chassis management card. |
| 1.3.6.1.4.1.674.10892.2.3.3 | NodedrsStatusChangeGroup | |||
| 1.3.6.1.4.1.674.10892.2.3.3.1 | ScalardrsGlobalChangeTime | read-only | mandatory | 0003.0003.0001 This attribute defines the timestamp of the most recent global status change. |
| 1.3.6.1.4.1.674.10892.2.3.3.2 | ScalardrsIOMChangeTime | read-only | mandatory | 0003.0003.0002 This attribute defines the timestamp of the most recent IOM status change. |
| 1.3.6.1.4.1.674.10892.2.3.3.3 | ScalardrsKVMChangeTime | read-only | mandatory | 0003.0003.0003 This attribute defines the timestamp of the most recent iKVM status change. |
| 1.3.6.1.4.1.674.10892.2.3.3.4 | ScalardrsRedChangeTime | read-only | mandatory | 0003.0003.0004 This attribute defines the timestamp of the most recent Redundancy status change. |
| 1.3.6.1.4.1.674.10892.2.3.3.5 | ScalardrsPowerChangeTime | read-only | mandatory | 0003.0003.0005 This attribute defines the timestamp of the most recent power health status change. |
| 1.3.6.1.4.1.674.10892.2.3.3.6 | ScalardrsFanChangeTime | read-only | mandatory | 0003.0003.0006 This attribute defines the timestamp of the most recent Fan health status change. |
| 1.3.6.1.4.1.674.10892.2.3.3.7 | ScalardrsBladeChangeTime | read-only | mandatory | 0003.0003.0007 This attribute defines the timestamp of the most recent Blade health status change. |
| 1.3.6.1.4.1.674.10892.2.3.3.8 | ScalardrsTempChangeTime | read-only | mandatory | 0003.0003.0008 This attribute defines the timestamp of the most recent Temp Sensor health status change. |
| 1.3.6.1.4.1.674.10892.2.3.3.9 | ScalardrsCMCChangeTime | read-only | mandatory | 0003.0003.0009 This attribute defines the timestamp of the most recent CMC health status change. |
| 1.3.6.1.4.1.674.10892.2.4 | NodedrsChassisPowerGroup | |||
| 1.3.6.1.4.1.674.10892.2.4.1 | TabledrsCMCPowerTable | not-accessible | mandatory | 0004.0001 This object defines the CMC power table. |
| 1.3.6.1.4.1.674.10892.2.4.1.1 | RowdrsCMCPowerTableEntry | not-accessible | mandatory | 0004.0001.0001 This object defines the CMC power table entry. |
| 1.3.6.1.4.1.674.10892.2.4.1.1.1 | ColumndrsChassisIndex | read-only | mandatory | 0004.0001.0001.0001 This attribute defines the index (one-based) of the associated chassis. |
| 1.3.6.1.4.1.674.10892.2.4.1.1.2 | ColumndrsPotentialPower | read-only | mandatory | 0004.0001.0001.0002 This attribute defines the power (in Watts) required by the chassis infrastructure, plus the sum of the maximum power requirements for all … |
| 1.3.6.1.4.1.674.10892.2.4.1.1.3 | ColumndrsIdlePower | read-only | mandatory | 0004.0001.0001.0003 This attribute defines the power (in Watts) required by the chassis infrastructure, plus the sum of the minimum power requirements for all … |
| 1.3.6.1.4.1.674.10892.2.4.1.1.4 | ColumndrsMaxPowerSpecification | read-only | mandatory | 0004.0001.0001.0004 This attribute defines the power limit (in Watts) at which server throttling will take place. |
| 1.3.6.1.4.1.674.10892.2.4.1.1.5 | ColumndrsPowerSurplus | read-only | mandatory | 0004.0001.0001.0005 This attribute defines the power surplus (in Watts) remaining above the drsPotentialPower reading. |
| 1.3.6.1.4.1.674.10892.2.4.1.1.6 | ColumndrsKWhCumulative | read-only | mandatory | 0004.0001.0001.0006 This attribute defines the cumulative chassis power usage (in KWh) since last reset. |
| 1.3.6.1.4.1.674.10892.2.4.1.1.7 | ColumndrsKWhCumulativeTime | read-only | mandatory | 0004.0001.0001.0007 This attribute defines the timestamp of the most recent chassis power accumulator reset. |
| 1.3.6.1.4.1.674.10892.2.4.1.1.8 | ColumndrsWattsPeakUsage | read-only | mandatory | 0004.0001.0001.0008 This attribute defines the chassis peak power usage (in Watts) since last reset. |
| 1.3.6.1.4.1.674.10892.2.4.1.1.9 | ColumndrsWattsPeakTime | read-only | mandatory | 0004.0001.0001.0009 This attribute defines the timestamp of the most recent chassis peak power usage. |
| 1.3.6.1.4.1.674.10892.2.4.1.1.10 | ColumndrsWattsMinUsage | read-only | mandatory | 0004.0001.0001.0010 This attribute defines the chassis mimimum power usage (in Watts) since last reset. |
| 1.3.6.1.4.1.674.10892.2.4.1.1.11 | ColumndrsWattsMinTime | read-only | mandatory | 0004.0001.0001.0011 This attribute defines the timestamp of the most recent chassis minimum power usage. |
| 1.3.6.1.4.1.674.10892.2.4.1.1.12 | ColumndrsWattsResetTime | read-only | mandatory | 0004.0001.0001.0012 This attribute defines the timestamp of the most recent reset of the chassis min/peak Watts readings. |
| 1.3.6.1.4.1.674.10892.2.4.1.1.13 | ColumndrsWattsReading | read-only | mandatory | 0004.0001.0001.0013 This attribute defines the instantaneous chassis power usage (in Watts). |
| 1.3.6.1.4.1.674.10892.2.4.1.1.14 | ColumndrsAmpsReading | read-only | mandatory | 0004.0001.0001.0014 This attribute defines the instantaneous chassis current usage (in Watts). |
| 1.3.6.1.4.1.674.10892.2.4.2 | TabledrsCMCPSUTable | not-accessible | mandatory | 0004.0002 This object defines the CMC PSU table. |
| 1.3.6.1.4.1.674.10892.2.4.2.1 | RowdrsCMCPSUTableEntry | not-accessible | mandatory | 0004.0002.0001 This object defines the CMC PSU table entry. |
| 1.3.6.1.4.1.674.10892.2.4.2.1.1 | ColumndrsPSUChassisIndex | read-only | mandatory | 0004.0002.0001.0001 This attribute defines the index (one-based) of the associated chassis. |
| 1.3.6.1.4.1.674.10892.2.4.2.1.2 | ColumndrsPSUIndex | read-only | mandatory | 0004.0002.0001.0002 This attribute defines the index (one-based) of the associated CMC PSU. |
| 1.3.6.1.4.1.674.10892.2.4.2.1.3 | ColumndrsPSULocation | read-only | mandatory | 0004.0002.0001.0003 This attribute defines the location of the CMC PSU. |
| 1.3.6.1.4.1.674.10892.2.4.2.1.4 | ColumndrsPSUMonitoringCapable | read-only | mandatory | 0004.0002.0001.0004 This attribute defines the PSU Monitoring capabilities, or the absence of a PSU in this location. |
| 1.3.6.1.4.1.674.10892.2.4.2.1.5 | ColumndrsPSUVoltsReading | read-only | mandatory | 0004.0002.0001.0005 This attribute defines the instantaneous PSU Voltage reading. |
| 1.3.6.1.4.1.674.10892.2.4.2.1.6 | ColumndrsPSUAmpsReading | read-only | mandatory | 0004.0002.0001.0006 This attribute defines the instantaneous PSU Current reading. |
| 1.3.6.1.4.1.674.10892.2.4.2.1.7 | ColumndrsPSUWattsReading | read-only | mandatory | 0004.0002.0001.0007 This attribute defines the instantaneous PSU Wattage reading. |
| 1.3.6.1.4.1.674.10892.2.5 | NodedrsChassisServerGroup | |||
| 1.3.6.1.4.1.674.10892.2.5.1 | TabledrsCMCServerTable | not-accessible | mandatory | 0005.0001 This object defines the CMC server table. |
| 1.3.6.1.4.1.674.10892.2.5.1.1 | RowdrsCMCServerTableEntry | not-accessible | mandatory | 0005.0001.0001 This object defines the CMC server table entry. |
| 1.3.6.1.4.1.674.10892.2.5.1.1.1 | ColumndrsServerIndex | read-only | mandatory | 0005.0001.0001.0001 This attribute defines the index (one-based) of the associated CMC server. |
| 1.3.6.1.4.1.674.10892.2.5.1.1.2 | ColumndrsServerMonitoringCapable | read-only | mandatory | 0005.0001.0001.0002 This attribute defines the server monitoring capabilities, or the absence of a server in this location. |
| 1.3.6.1.4.1.674.10892.2.5.1.1.3 | ColumndrsServerServiceTag | read-only | mandatory | 0005.0001.0001.0003 This attribute defines the Service Tag of the CMC server. |
| 1.3.6.1.4.1.674.10892.2.5.1.1.4 | ColumndrsServerSlotName | read-only | mandatory | 0005.0001.0001.0004 This attribute defines the Slot Name of the CMC server. |
| 1.3.6.1.4.1.674.10892.2.5.1.1.5 | ColumndrsServerSlotNumber | read-only | mandatory | 0005.0001.0001.0005 This attribute defines the Chassis Slot Number of the CMC server. |
| 1.3.6.1.4.1.674.10892.2.5.1.1.6 | ColumndrsServerNodeID | read-only | mandatory | 0005.0001.0001.0006 This attribute defines the Node ID of the CMC server. The Node ID provides a unique identifier for the server. |
| 1.3.6.1.4.1.674.10892.2.5.1.1.7 | ColumndrsServerModel | read-only | mandatory | 0005.0001.0001.0007 This attribute defines the Model of the CMC server. |
| 1.3.6.1.4.1.674.10892.2.5.1.1.8 | ColumndrsServerAssetTag | read-only | mandatory | 0005.0001.0001.0008 This attribute defines the Asset Tag of the CMC server. |
| 1.3.6.1.4.1.674.10892.2.5.1.1.9 | ColumndrsServerNumStorageControllers | read-only | mandatory | 0005.0001.0001.0009 This attribute defines the number of storage controllers on the storage sled. The value will be zero if this is not a storage sled. |
| 1.3.6.1.4.1.674.10892.2.5.1.1.10 | ColumndrsServerStorageMode | read-only | mandatory | 0005.0001.0001.0010 This attribute defines the Storage Mode of the storage sled. |
| 1.3.6.1.4.1.674.10892.2.5.1.1.11 | ColumndrsServerIntrusionState | read-only | mandatory | 0005.0001.0001.0011 This attribute defines the Intrusion State of the CMC server if supported by the server. |
| 1.3.6.1.4.1.674.10892.2.5.1.1.12 | ColumndrsServerAssignedServerSlots | read-only | mandatory | 0005.0001.0001.0012 This attribute defines the the server slots to which a storage sled is assigned. If this is a storage sled that is assigned to one more or … |
| 1.3.6.1.4.1.674.10892.2.20 | NodedrsCMCAlertGroup | |||
| 1.3.6.1.4.1.674.10892.2.20.10 | NodedrsChassisAlertVariables | |||
| 1.3.6.1.4.1.674.10892.2.20.10.1 | ScalardrsCASubSystem | read-only | mandatory | 0020.0010.0001 This attribute defines the Sub-System Name of the CMC Alert |
| 1.3.6.1.4.1.674.10892.2.20.10.2 | ScalardrsCASSCurrStatus | read-only | mandatory | 0020.0010.0002 This attribute defines the Current Status of the Alerting Sub-System |
| 1.3.6.1.4.1.674.10892.2.20.10.3 | ScalardrsCASSPrevStatus | read-only | mandatory | 0020.0010.0003 This attribute defines the Previous Status of the Alerting Sub-System |
| 1.3.6.1.4.1.674.10892.2.20.10.4 | ScalardrsCASSChangeTime | read-only | mandatory | 0020.0010.0004 This attribute defines the Timestamp of Most Recent Change of the Alerting Sub-System |
| 1.3.6.1.4.1.674.10892.2.20.10.5 | ScalardrsCAMessage | read-only | mandatory | 0020.0010.0005 This attribute defines the CSSD message of the CMC Alert |
| 1.3.6.1.4.1.674.10892.2.21 | NodedrsCMCAlert2Group | |||
| 1.3.6.1.4.1.674.10892.2.21.10 | NodedrsChassisAlert2Variables | |||
| 1.3.6.1.4.1.674.10892.2.21.10.1 | ScalardrsCA2MessageID | read-only | mandatory | Message ID of the alert. |
| 1.3.6.1.4.1.674.10892.2.21.10.2 | ScalardrsCA2Message | read-only | mandatory | Message describing the alert. |
| 1.3.6.1.4.1.674.10892.2.21.10.3 | ScalardrsCA2MessageArgs | read-only | mandatory | Concatenated set of strings representing any message arguments that were used to construct the alert message. Each message argument string is enclosed in doubl… |
| 1.3.6.1.4.1.674.10892.2.21.10.4 | ScalardrsCA2AlertStatus | read-only | mandatory | Status of the alert. |
| 1.3.6.1.4.1.674.10892.2.21.10.5 | ScalardrsCA2FQDD | read-only | mandatory | Fully qualified device descriptor of device causing the alert. |
| 1.3.6.1.4.1.674.10892.2.21.2153 | Nodealert2FanFailure | Fan failure. | ||
| 1.3.6.1.4.1.674.10892.2.21.2154 | Nodealert2FanWarning | Fan warning. | ||
| 1.3.6.1.4.1.674.10892.2.21.2155 | Nodealert2FanInformation | Fan information. | ||
| 1.3.6.1.4.1.674.10892.2.21.2161 | Nodealert2TemperatureProbeFailure | Temperature sensor has detected a failure value. | ||
| 1.3.6.1.4.1.674.10892.2.21.2162 | Nodealert2TemperatureProbeWarning | Temperature sensor has detected a warning value. | ||
| 1.3.6.1.4.1.674.10892.2.21.2163 | Nodealert2TemperatureProbeNormal | Temperature sensor value is within range. | ||
| 1.3.6.1.4.1.674.10892.2.21.2169 | Nodealert2VoltageProbeFailure | Voltage sensor has detected a failure value. | ||
| 1.3.6.1.4.1.674.10892.2.21.2170 | Nodealert2VoltageProbeWarning | Voltage sensor has detected a warning value. | ||
| 1.3.6.1.4.1.674.10892.2.21.2171 | Nodealert2VoltageProbeNormal | Voltage sensor reading is within range. | ||
| 1.3.6.1.4.1.674.10892.2.21.2177 | Nodealert2AmperageProbeFailure | Current sensor has detected a failure value. | ||
| 1.3.6.1.4.1.674.10892.2.21.2178 | Nodealert2AmperageProbeWarning | Current sensor has detected a warning value. | ||
| 1.3.6.1.4.1.674.10892.2.21.2179 | Nodealert2AmperageProbeNormal | Current sensor reading is within range. | ||
| 1.3.6.1.4.1.674.10892.2.21.2185 | Nodealert2PowerSupplyFailure | Power supply has detected a failure. | ||
| 1.3.6.1.4.1.674.10892.2.21.2186 | Nodealert2PowerSupplyWarning | Power supply has detected a warning. | ||
| 1.3.6.1.4.1.674.10892.2.21.2187 | Nodealert2PowerSupplyNormal | Power supply has returned to normal. | ||
| 1.3.6.1.4.1.674.10892.2.21.2225 | Nodealert2BatteryFailure | Battery has failed or battery is absent. | ||
| 1.3.6.1.4.1.674.10892.2.21.2226 | Nodealert2BatteryWarning | Battery is low. | ||
| 1.3.6.1.4.1.674.10892.2.21.2227 | Nodealert2BatteryNormal | Battery state has returned to normal; or battery presence had been detected. | ||
| 1.3.6.1.4.1.674.10892.2.21.2249 | Nodealert2LinkStatusFailure | Link status failure or critical event. | ||
| 1.3.6.1.4.1.674.10892.2.21.2250 | Nodealert2LinkStatusWarning | Link status warning. | ||
| 1.3.6.1.4.1.674.10892.2.21.2251 | Nodealert2LinkStatusInformation | Link status information. | ||
| 1.3.6.1.4.1.674.10892.2.21.2273 | Nodealert2PowerUsageFailure | Power usage failure. | ||
| 1.3.6.1.4.1.674.10892.2.21.2274 | Nodealert2PowerUsageWarning | Power usage warning. | ||
| 1.3.6.1.4.1.674.10892.2.21.2275 | Nodealert2PowerUsageInformation | Power usage information. | ||
| 1.3.6.1.4.1.674.10892.2.21.2329 | Nodealert2HardwareConfigurationFailure | Hardware configuration failure or critical event. | ||
| 1.3.6.1.4.1.674.10892.2.21.2330 | Nodealert2HardwareConfigurationWarning | Hardware configuration warning. | ||
| 1.3.6.1.4.1.674.10892.2.21.2331 | Nodealert2HardwareConfigurationInformation | Hardware configuration information. | ||
| 1.3.6.1.4.1.674.10892.2.21.2337 | Nodealert2SoftwareConfigurationFailure | Software configuration failure. | ||
| 1.3.6.1.4.1.674.10892.2.21.2338 | Nodealert2SoftwareConfigurationWarning | Software configuration warning. | ||
| 1.3.6.1.4.1.674.10892.2.21.2339 | Nodealert2SoftwareConfigurationInformation | Software configuration information. | ||
| 1.3.6.1.4.1.674.10892.2.21.2377 | Nodealert2SystemEventLogFailure | System Event Log failure or critical event. | ||
| 1.3.6.1.4.1.674.10892.2.21.2378 | Nodealert2SystemEventLogWarning | System Event Log warning. | ||
| 1.3.6.1.4.1.674.10892.2.21.2379 | Nodealert2SystemEventLogInformation | System Event Log information. | ||
| 1.3.6.1.4.1.674.10892.2.21.2385 | Nodealert2SecurityFailure | Security failure or critical event. | ||
| 1.3.6.1.4.1.674.10892.2.21.2386 | Nodealert2SecurityWarning | Security warning. | ||
| 1.3.6.1.4.1.674.10892.2.21.2387 | Nodealert2SecurityInformation | Security information. | ||
| 1.3.6.1.4.1.674.10892.2.21.2393 | Nodealert2CableFailure | Cable failure. | ||
| 1.3.6.1.4.1.674.10892.2.21.2417 | Nodealert2PCIDeviceFailure | PCI device failure or critical event. | ||
| 1.3.6.1.4.1.674.10892.2.21.2418 | Nodealert2PCIDeviceWarning | PCI device warning. | ||
| 1.3.6.1.4.1.674.10892.2.21.2419 | Nodealert2PCIDeviceInformation | PCI device information. | ||
| 1.3.6.1.4.1.674.10892.2.21.2465 | Nodealert2PowerSupplyAbsent | Power supply is absent. | ||
| 1.3.6.1.4.1.674.10892.2.21.2473 | Nodealert2RedundancyLost | Redundancy is lost. | ||
| 1.3.6.1.4.1.674.10892.2.21.2474 | Nodealert2RedundancyDegraded | Redundancy is degraded. | ||
| 1.3.6.1.4.1.674.10892.2.21.2475 | Nodealert2RedundancyInformation | Redundancy information. | ||
| 1.3.6.1.4.1.674.10892.2.21.2545 | Nodealert2CMCFailure | Chassis Management Controller detected an error. | ||
| 1.3.6.1.4.1.674.10892.2.21.2546 | Nodealert2CMCWarning | Chassis Management Controller detected a warning. | ||
| 1.3.6.1.4.1.674.10892.2.21.2553 | Nodealert2IOVirtualizationFailure | IO Virtualization failure or critical event. | ||
| 1.3.6.1.4.1.674.10892.2.21.2554 | Nodealert2IOVirtualizationWarning | IO Virtualization warning. | ||
| 1.3.6.1.4.1.674.10892.2.21.2555 | Nodealert2IOVirtualizationInformation | IO Virtualization information. | ||
| 1.3.6.1.4.1.674.10892.2.21.4177 | Nodealert2StorageManagementFailure | Storage Management has detected a device independent error condition. There is no global status change associated with this trap. | ||
| 1.3.6.1.4.1.674.10892.2.21.4178 | Nodealert2StorageManagementWarning | Storage Management has detected a device independent warning condition. There is no global status change associated with this trap. | ||
| 1.3.6.1.4.1.674.10892.2.21.4179 | Nodealert2StorageManagementInformation | Storage Management information. There is no global status change associated with this trap. | ||
| 1.3.6.1.4.1.674.10892.2.21.4201 | Nodealert2StorageFanFailure | Storage Fan failure. | ||
| 1.3.6.1.4.1.674.10892.2.21.4202 | Nodealert2StorageFanWarning | Storage Fan warning. | ||
| 1.3.6.1.4.1.674.10892.2.21.4203 | Nodealert2StorageFanInformation | Storage Fan information. | ||
| 1.3.6.1.4.1.674.10892.2.21.4209 | Nodealert2StorageTemperatureProbeFailure | Storage Temperature probe failure. | ||
| 1.3.6.1.4.1.674.10892.2.21.4210 | Nodealert2StorageTemperatureProbeWarning | Storage Temperature probe warning. | ||
| 1.3.6.1.4.1.674.10892.2.21.4211 | Nodealert2StorageTemperatureProbeInformation | Storage Temperature probe information. | ||
| 1.3.6.1.4.1.674.10892.2.21.4233 | Nodealert2StoragePowerSupplyFailure | Storage Power supply failure. | ||
| 1.3.6.1.4.1.674.10892.2.21.4234 | Nodealert2StoragePowerSupplyWarning | Storage Power supply warning. | ||
| 1.3.6.1.4.1.674.10892.2.21.4235 | Nodealert2StoragePowerSupplyInformation | Storage Power supply information. | ||
| 1.3.6.1.4.1.674.10892.2.21.4273 | Nodealert2StorageBatteryFailure | Storage Battery failure. | ||
| 1.3.6.1.4.1.674.10892.2.21.4274 | Nodealert2StorageBatteryWarning | Storage Battery warning. | ||
| 1.3.6.1.4.1.674.10892.2.21.4275 | Nodealert2StorageBatteryInformation | Storage Battery information. | ||
| 1.3.6.1.4.1.674.10892.2.21.4329 | Nodealert2StorageControllerFailure | Storage Controller failure. | ||
| 1.3.6.1.4.1.674.10892.2.21.4330 | Nodealert2StorageControllerWarning | Storage Controller warning. | ||
| 1.3.6.1.4.1.674.10892.2.21.4331 | Nodealert2StorageControllerInformation | Storage Controller information. | ||
| 1.3.6.1.4.1.674.10892.2.21.4337 | Nodealert2StorageEnclosureFailure | Storage Enclosure failure. | ||
| 1.3.6.1.4.1.674.10892.2.21.4338 | Nodealert2StorageEnclosureWarning | Storage Enclosure warning. | ||
| 1.3.6.1.4.1.674.10892.2.21.4339 | Nodealert2StorageEnclosureInformation | Storage Enclosure information. | ||
| 1.3.6.1.4.1.674.10892.2.21.4345 | Nodealert2StoragePhysicalDiskFailure | Storage Physical disk failure. | ||
| 1.3.6.1.4.1.674.10892.2.21.4346 | Nodealert2StoragePhysicalDiskWarning | Storage Physical disk warning. | ||
| 1.3.6.1.4.1.674.10892.2.21.4347 | Nodealert2StoragePhysicalDiskInformation | Storage Physical disk information. | ||
| 1.3.6.1.4.1.674.10892.2.21.4353 | Nodealert2StorageVirtualDiskFailure | Storage Virtual disk failure. | ||
| 1.3.6.1.4.1.674.10892.2.21.4354 | Nodealert2StorageVirtualDiskWarning | Storage Virtual disk warning. | ||
| 1.3.6.1.4.1.674.10892.2.21.4355 | Nodealert2StorageVirtualDiskInformation | Storage Virtual disk information. | ||
| 1.3.6.1.4.1.674.10892.2.21.4433 | Nodealert2StorageSecurityFailure | Storage Security failure or critical event. | ||
| 1.3.6.1.4.1.674.10892.2.21.4434 | Nodealert2StorageSecurityWarning | Storage Security warning. | ||
| 1.3.6.1.4.1.674.10892.2.21.4435 | Nodealert2StorageSecurityInformation | Storage Security information. | ||
| 1.3.6.1.4.1.674.10892.2.21.6314 | Nodealert2SoftwareChangeUpdateWarning | Software change update warning. | ||
| 1.3.6.1.4.1.674.10892.2.21.8329 | Nodealert2PowerSupplyAuditFailure | Power Supply audit failure or critical event. | ||
| 1.3.6.1.4.1.674.10892.2.21.8330 | Nodealert2PowerSupplyAuditWarning | Power Supply audit warning. | ||
| 1.3.6.1.4.1.674.10892.2.21.8361 | Nodealert2SoftwareChangeAuditFailure | Software change audit failure or critical event. | ||
| 1.3.6.1.4.1.674.10892.2.21.8417 | Nodealert2PowerUsageAuditFailure | Power usage audit failure or critical event. | ||
| 1.3.6.1.4.1.674.10892.2.21.8418 | Nodealert2PowerUsageAuditWarning | Power usage audit warning. | ||
| 1.3.6.1.4.1.674.10892.2.21.8419 | Nodealert2PowerUsageAuditInformation | Power usage audit information. | ||
| 1.3.6.1.4.1.674.10892.2.21.8513 | Nodealert2LicenseFailure | License failure. | ||
| 1.3.6.1.4.1.674.10892.2.21.8514 | Nodealert2LicenseWarning | License warning. | ||
| 1.3.6.1.4.1.674.10892.2.21.8515 | Nodealert2LicenseInformation | License information. | ||
| 1.3.6.1.4.1.674.10892.2.21.8562 | Nodealert2PCIDeviceAuditWarning | PCI device audit warning. | ||
| 1.3.6.1.4.1.674.10892.2.21.8689 | Nodealert2CMCAuditFailure | Chassis Management Controller audit failure or critical event. | ||
| 1.3.6.1.4.1.674.10892.2.21.8690 | Nodealert2CMCAuditWarning | Chassis Management Controller audit warning. | ||
| 1.3.6.1.4.1.674.10892.2.21.8691 | Nodealert2CMCAuditInformation | Chassis Management Controller audit information. | ||
| 1.3.6.1.4.1.674.10892.2.21.8698 | Nodealert2IOVirtualizationAuditWarning | IO Virtualization audit warning. | ||
| 1.3.6.1.4.1.674.10892.2.21.10395 | Nodealert2CMCTestTrap | Test trap generated by CMC in response to a user request. | ||
| 1.3.6.1.4.1.674.10892.2.21.10529 | Nodealert2SWCConfigurationFailure | Software configuration failure. | ||
| 1.3.6.1.4.1.674.10892.2.21.10530 | Nodealert2SWCConfigurationWarning | Software configuration warning. | ||
| 1.3.6.1.4.1.674.10892.2.21.10611 | Nodealert2PCIDeviceConfigurationInformation | PCI device configuration information. | ||
| 1.3.6.1.4.1.674.10892.2.21.10746 | Nodealert2IOVConfigurationWarning | IO Virtualization configuration warning. | ||
| 1.3.6.1.4.1.674.10892.2.21.10747 | Nodealert2IOVConfigurationInformation | IO Virtualization configuration information. | ||
| 1.3.6.1.4.1.674.10892.2.1001 | NodealertDrscTestTrapEvent | The RAC generated a test trap event in response to a user request. | ||
| 1.3.6.1.4.1.674.10892.2.1002 | NodealertDrscAuthError | The RAC Authentication Failures during a time period have Exceeded a Threshold. | ||
| 1.3.6.1.4.1.674.10892.2.1003 | NodealertDrscLostESM | The RAC cannot communicate with the baseboard management controller (ESM). | ||
| 1.3.6.1.4.1.674.10892.2.1004 | NodealertDrscFoundESM | The RAC is communicating normally with the baseboard management controller (ESM). | ||
| 1.3.6.1.4.1.674.10892.2.1005 | NodealertDrscPowerOff | The RAC has detected a System power state change to powered-off. | ||
| 1.3.6.1.4.1.674.10892.2.1006 | NodealertDrscPowerOn | The RAC has detected a system power state change to powered-on. | ||
| 1.3.6.1.4.1.674.10892.2.1007 | NodealertDrscWatchdogExpired | The RAC has detected that the system watchdog has expired indicating a system hang. | ||
| 1.3.6.1.4.1.674.10892.2.1008 | NodealertDrscBattLow | The RAC Battery charge is below 25% indicating that the battery may only be able to power the DRSC for 8-10 minutes. | ||
| 1.3.6.1.4.1.674.10892.2.1009 | NodealertDrscTempNormal | The RAC Temperature probe has retured to a normal value. | ||
| 1.3.6.1.4.1.674.10892.2.1010 | NodealertDrscTempWarning | The RAC Temperature probe has detected a Warning value. | ||
| 1.3.6.1.4.1.674.10892.2.1011 | NodealertDrscTempCritical | The RAC Temperature probe has detected a failure (or critical) value. | ||
| 1.3.6.1.4.1.674.10892.2.1012 | NodealertDrscVoltNormal | The RAC voltage has returned to a normal value. | ||
| 1.3.6.1.4.1.674.10892.2.1013 | NodealertDrscVoltWarning | The RAC voltage probe has detected a warning value. | ||
| 1.3.6.1.4.1.674.10892.2.1014 | NodealertDrscVoltCritical | The RAC voltage probe has detected a failure (or critical) value. | ||
| 1.3.6.1.4.1.674.10892.2.1015 | NodealertDrscSELWarning | The RAC has detected a new event in the System Event Log with Severity: Warning. | ||
| 1.3.6.1.4.1.674.10892.2.1016 | NodealertDrscSELCritical | The RAC has detected a new event in the System Event Log with Severity: Critical. | ||
| 1.3.6.1.4.1.674.10892.2.1017 | NodealertDrscSEL80percentFull | The RAC has detected that the System Event Log is 80% full. | ||
| 1.3.6.1.4.1.674.10892.2.1018 | NodealertDrscSEL90percentFull | The RAC has detected that the System Event Log is 90% full. | ||
| 1.3.6.1.4.1.674.10892.2.1019 | NodealertDrscSEL100percentFull | The RAC has detected that the System Event Log is 100% full. | ||
| 1.3.6.1.4.1.674.10892.2.1020 | NodealertDrscSELNormal | The RAC has detected a new event in the System Event Log with Severity: Normal. | ||
| 1.3.6.1.4.1.674.10892.2.2000 | NodealertCMCTestTrap | The CMC has generated a test trap | ||
| 1.3.6.1.4.1.674.10892.2.2002 | NodealertCMCNormalTrap | The CMC reported a return-to-normal or informational event. | ||
| 1.3.6.1.4.1.674.10892.2.2003 | NodealertCMCWarningTrap | The CMC reported a warning event. | ||
| 1.3.6.1.4.1.674.10892.2.2004 | NodealertCMCCriticalTrap | The CMC reported a critical event. | ||
| 1.3.6.1.4.1.674.10892.2.2005 | NodealertCMCNonRecoverableTrap | The CMC reported a catastrophic event. | ||
| 1.3.6.1.4.1.674.10892.2.5000 | NodedrsAlertGroup | |||
| 1.3.6.1.4.1.674.10892.2.5000.10 | NodedrsAlertVariables | |||
| 1.3.6.1.4.1.674.10892.2.5000.10.1 | ScalardrsAlertSystem | read-only | mandatory | 5000.0010.0001 Name of the system generating the alert. |
| 1.3.6.1.4.1.674.10892.2.5000.10.2 | ScalardrsAlertTableIndexOID | read-only | mandatory | 5000.0010.0002 0.0 |
| 1.3.6.1.4.1.674.10892.2.5000.10.3 | ScalardrsAlertMessage | read-only | mandatory | 5000.0010.0003 Message describing the alert. |
| 1.3.6.1.4.1.674.10892.2.5000.10.4 | ScalardrsAlertCurrentStatus | read-only | mandatory | 5000.0010.0004 Current status of object causing the alert. |
| 1.3.6.1.4.1.674.10892.2.5000.10.5 | ScalardrsAlertPreviousStatus | read-only | mandatory | 5000.0010.0005 Previous status of object causing the alert. |
| 1.3.6.1.4.1.674.10892.2.5000.10.6 | ScalardrsAlertData | read-only | mandatory | 5000.0010.0006 Alert data. |
Type Definitions
| Name | Syntax | Status | Description |
|---|---|---|---|
| DellCMCPowerIndexRange | INTEGER (1..1) | ||
| DellCMCPSUCapable | INTEGER { absent(1), none(2), basic(3) } | ||
| DellCMCPSUIndexRange | INTEGER (1..6) | ||
| DellCMCServerCapable | INTEGER { absent(1), none(2), basic(3), off(4) } | ||
| DellCMCServerIndexRange | INTEGER (1..32) | ||
| DellCMCServerIntrusionState | INTEGER { notApplicable(1), closed(2), open(3), unknown(99) } | ||
| DellCMCServerStorageMode | INTEGER { notApplicable(1), joined(2), splitDualHost(3), splitSingleHost(4), unknown(99) } | ||
| DellRacType | INTEGER { other(1), unknown(2), dracIII(3), era(4), drac4(5), drac5(6), drac5MC(7), cmc(8), idrac(9), idrac7monolithic(16), idrac7modular(17), vrtxCMC(18), fx2CMC(19), idrac8monolithic(32), idrac8modular(33) } | ||
| DellStatus | INTEGER { other(1), unknown(2), | ||
| DellTemperatureReading | INTEGER |