DES7200-SYSTEM-MIB

59 objects
This module defines my system mibs.
Imported Objects
DES7200-SMImyMgmt
SNMPv2-CONFMODULE-COMPLIANCE OBJECT-GROUP
SNMPv2-SMIInteger32 MODULE-IDENTITY NOTIFICATION-TYPE OBJECT-TYPE Unsigned32
SNMPv2-TCDisplayString
OIDNameAccessStatusDescription
1.3.6.1.4.1.171.10.97.2.1IdentitymySystemMIBThis module defines my system mibs.
1.3.6.1.4.1.171.10.97.2.1.1NodemySystemMIBObjects
1.3.6.1.4.1.171.10.97.2.1.1.1ScalarmySystemHwVersionread-onlycurrentReturn the string of the Revision number of hardware resides on the FastSwitch.
1.3.6.1.4.1.171.10.97.2.1.1.2ScalarmySystemSwVersionread-onlycurrentReturn the string of the Revision number of software resides on the FastSwitch.
1.3.6.1.4.1.171.10.97.2.1.1.3ScalarmySystemBootVersionread-onlycurrentReturn the string of the Revision number of BOOT software resides on the FastSwitch.
1.3.6.1.4.1.171.10.97.2.1.1.4ScalarmySystemSysCtrlVersionread-onlycurrentReturn the string of the Revision number of CTRL software resides on the FastSwitch.
1.3.6.1.4.1.171.10.97.2.1.1.5ScalarmySystemParametersSaveread-writecurrentSave all parameters changed in configuration by setting this object to any value but 0, set its value to 0 will cause no action of agent, otherwise all changes…
1.3.6.1.4.1.171.10.97.2.1.1.6ScalarmySystemOutBandRateread-writecurrentDetermine the console(OutBand) baud rate : 9600 - 1,19200 - 2, 38300 - 3, 57600 - 4, 115200 - 5, when the console baud rate is other value will return value 0.
1.3.6.1.4.1.171.10.97.2.1.1.7ScalarmySystemResetread-writecurrentThis Object allow perform soft reset of system by setting its value to none zero. if a soft resetis performed, after this having completed a warm start trap wi…
1.3.6.1.4.1.171.10.97.2.1.1.8ScalarmySwitchLayerread-onlycurrentWhich layer's device the switch in system
1.3.6.1.4.1.171.10.97.2.1.1.9ScalarmySystemHwPowerread-onlycurrentThe state of power.
1.3.6.1.4.1.171.10.97.2.1.1.10ScalarmySystemHwFanread-onlycurrentThe state of fan.
1.3.6.1.4.1.171.10.97.2.1.1.11ScalarmySystemOutBandTimeoutread-writeobsoleteThe timeout of console.0 indicate that timeout function is disabled.
1.3.6.1.4.1.171.10.97.2.1.1.12ScalarmySystemTelnetTimeoutread-writeobsoleteThe timeout of telnet.0 indicate that timeout function is disabled.
1.3.6.1.4.1.171.10.97.2.1.1.13ScalarmySystemMainFileread-onlycurrentReturn the string of the name of main file on the FastSwitch.
1.3.6.1.4.1.171.10.97.2.1.1.14ScalarmySystemCurrentPowerread-onlycurrentReturn the current power of the FastSwitch.
1.3.6.1.4.1.171.10.97.2.1.1.15ScalarmySystemRemainPowerread-onlycurrentReturn the remain power of the FastSwitch.
1.3.6.1.4.1.171.10.97.2.1.1.16ScalarmySystemTemperatureread-onlycurrentReturn the temperature of the FastSwitch.
1.3.6.1.4.1.171.10.97.2.1.1.17ScalarmySystemElectricalSourceNumread-onlycurrentReturn the electrical source number of the FastSwitch.
1.3.6.1.4.1.171.10.97.2.1.1.18TablemySystemElectricalSourceIsNormalTablenot-accessiblecurrentA table of electrical source entries. Each object displays whether different electrical sources are normal or not.
1.3.6.1.4.1.171.10.97.2.1.1.18.1RowmySystemElectricalSourceIsNormalEntrynot-accessiblecurrentAn entry displays whether different electrical sources are normal or not.
1.3.6.1.4.1.171.10.97.2.1.1.18.1.1ColumnmySystemElectricalSourceIsNormalIndexread-onlycurrentAn index that uniquely represents a electrical source.
1.3.6.1.4.1.171.10.97.2.1.1.18.1.2ColumnmySystemElectricalSourceIsNormalread-onlycurrentThis object displays whether an electrical source is normal or not.
1.3.6.1.4.1.171.10.97.2.1.1.18.1.3ColumnmySystemElectricalSourceNameread-onlycurrentThe name of electrical source
1.3.6.1.4.1.171.10.97.2.1.1.19ScalarmySystemCurrentVoltageread-onlycurrentReturn the current voltage of the FastSwitch.
1.3.6.1.4.1.171.10.97.2.1.1.20ScalarmySystemFanNUMread-onlycurrentReturn the number of fan on the FastSwitch.
1.3.6.1.4.1.171.10.97.2.1.1.21TablemySystemFanIsNormalTablenot-accessiblecurrentA table of fan entries. Each object displays whether different fans are normal or not.
1.3.6.1.4.1.171.10.97.2.1.1.21.1RowmySystemFanIsNormalEntrynot-accessiblecurrentAn entry displays whether different fans are normal or not.
1.3.6.1.4.1.171.10.97.2.1.1.21.1.1ColumnmySystemFanIsNormalIndexread-onlycurrentAn index that uniquely represents a fan.
1.3.6.1.4.1.171.10.97.2.1.1.21.1.2ColumnmySystemFanIsNormalread-onlycurrentThis object displays whether an fan is normal or not.
1.3.6.1.4.1.171.10.97.2.1.1.21.1.3ColumnmySystemFanNameread-onlycurrentThe name of fan
1.3.6.1.4.1.171.10.97.2.1.1.22ScalarmySystemReloadTimeRemainread-onlycurrentReturn the remain time of reloading on the FastSwitch.
1.3.6.1.4.1.171.10.97.2.1.1.23TablemySystemTemperatureTablenot-accessiblecurrentA table of temperature entries. Each object displays the temperature information.
1.3.6.1.4.1.171.10.97.2.1.1.23.1RowmySystemTemperatureEntrynot-accessiblecurrentAn entry displays the temperature information.
1.3.6.1.4.1.171.10.97.2.1.1.23.1.1ColumnmySystemTemperatureIndexread-onlycurrentAn index that uniquely represents a device's temperature information.
1.3.6.1.4.1.171.10.97.2.1.1.23.1.2ColumnmySystemTemperatureNameread-onlycurrentA textual name assigned to a temperature chip
1.3.6.1.4.1.171.10.97.2.1.1.23.1.3ColumnmySystemTemperatureCurrentread-onlycurrentReturn the current temperature of the FastSwitch.The temperature display is not supported for the current temperature returns to 0.
1.3.6.1.4.1.171.10.97.2.1.1.23.1.4ColumnmySystemTemperatureWarningVauleread-writecurrentThe first warning of temperature of FastSwitch.
1.3.6.1.4.1.171.10.97.2.1.1.23.1.5ColumnmySystemTemperatureCritialVauleread-writecurrentThe second warning of temperature of FastSwitch.
1.3.6.1.4.1.171.10.97.2.1.1.24ScalarmySystemSerialnoread-onlycurrentReturn the string of the serial number resides on the FastSwitch.
1.3.6.1.4.1.171.10.97.2.1.1.25TablemySystemVersionTablenot-accessiblecurrentA table of system version entries. Each object displays the system version information.
1.3.6.1.4.1.171.10.97.2.1.1.25.1RowmySystemVersionEntrynot-accessiblecurrentAn entry displays the system version information.
1.3.6.1.4.1.171.10.97.2.1.1.25.1.1ColumnmySystemVersionIndexread-onlycurrentAn index that uniquely represents a device's system version information.
1.3.6.1.4.1.171.10.97.2.1.1.25.1.2ColumnmySystemVersionNameread-onlycurrentA textual name assigned to a system version chip
1.3.6.1.4.1.171.10.97.2.1.1.25.1.3ColumnmySystemVersionSwBootread-onlycurrentReturn the software boot system version of the FastSwitch.
1.3.6.1.4.1.171.10.97.2.1.1.25.1.4ColumnmySystemVersionSwCtrlread-onlycurrentReturn the software ctrl system version of the FastSwitch.
1.3.6.1.4.1.171.10.97.2.1.1.25.1.5ColumnmySystemVersionSwMainread-onlycurrentReturn the software main system version of the FastSwitch.
1.3.6.1.4.1.171.10.97.2.1.1.25.1.6ColumnmySystemVersionHwread-onlycurrentReturn the hardware system version of the FastSwitch.
1.3.6.1.4.1.171.10.97.2.1.1.25.1.7ColumnmySystemVersionSerialnoread-onlycurrentReturn the serial number of the FastSwitch.
1.3.6.1.4.1.171.10.97.2.1.2NodemySystemMIBTraps
1.3.6.1.4.1.171.10.97.2.1.2.1ScalarmySystemHardChangeDescaccessible-for-notifycurrentThe description of hard change
1.3.6.1.4.1.171.10.97.2.1.2.2NotificationmySystemHardChangeDetectedcurrentSystem hardware has changed include number of devices or number of modules or the place or type of the module is change.
1.3.6.1.4.1.171.10.97.2.1.2.3NotificationmySystemPowerStateChangecurrentwhile the state of power changed, then this trap will be sent.
1.3.6.1.4.1.171.10.97.2.1.2.4NotificationmySystemFanStateChangecurrentwhile the state of fan changed, then this trap will be sent.
1.3.6.1.4.1.171.10.97.2.1.3NodemySystemMIBConformance
1.3.6.1.4.1.171.10.97.2.1.3.1NodemySystemMIBCompliances
1.3.6.1.4.1.171.10.97.2.1.3.1.1CompliancemySystemMIBCompliancecurrentThe compliance statement for entities which implement the My System MIB
1.3.6.1.4.1.171.10.97.2.1.3.2NodemySystemMIBGroups
1.3.6.1.4.1.171.10.97.2.1.3.2.1GroupmySystemMIBGroupcurrentA collection of objects providing system information and opertion to a My agent.