MIB Viewer

DEV-CFG-MIB

95 objects
No module-level DESCRIPTION found.
OIDNameAccessStatusDescription
1.3.6.1.4.1.629.1.50.11NodenbDeviceConfig
1.3.6.1.4.1.629.1.50.11.1NodenbDevGen
1.3.6.1.4.1.629.1.50.11.1.1ScalarnbDevOperationModeread-onlymandatoryThe Operational mode of Device. This is for internal usage.
1.3.6.1.4.1.629.1.50.11.1.2ScalarnbDevErrorTextread-onlymandatoryThis is the text of the last error that the agent found. it is sent to the RS232 port, and it used by the manager to show the cause of the last error.
1.3.6.1.4.1.629.1.50.11.1.3ScalarnbsDevTftpModeread-writemandatoryThe TFTP Download Process mode of the Device. The 'client' mode is a default.
1.3.6.1.4.1.629.1.50.11.1.4ScalarnbDevRouterSaveConfigread-writemandatoryIf operation SET is issued with value saveConfig(1), all configuration is to be saved in relevant configuration files; SET with value warmReset(2) causes only …
1.3.6.1.4.1.629.1.50.11.1.5ScalarnbsDevPropertiesread-onlymandatoryAdditional Device Properties. This MIB Object is created as a Bits Mask, when the corresponding Bit says about the specific property. value=0 : If no additiona…
1.3.6.1.4.1.629.1.50.11.1.6ScalarnbsDevTemperatureModeread-onlymandatoryThe Temperature Mode of Device.
1.3.6.1.4.1.629.1.50.11.1.7NodeinvalidPasswordThe SNMP trap that is generated when invalid password was used in the current protocol session.
1.3.6.1.4.1.629.1.50.11.1.7ScalarnbsDevResetAfterDnldModeread-writemandatoryDevice Reset Mode after Download process. In case of 'yes'(2) the Reset will be created immediately after the Download process will successfuly finish; In case…
1.3.6.1.4.1.629.1.50.11.1.8NodenbsDevPS
1.3.6.1.4.1.629.1.50.11.1.8NodewrongAccessThe SNMP trap that is generated when wrong access attempt is occured.
1.3.6.1.4.1.629.1.50.11.1.8.1ScalarnbsDevPSNumberread-onlymandatoryThe number of Power Supplies in the corresponding Device. Value = 0 says, that Power Supply Table is not supported.
1.3.6.1.4.1.629.1.50.11.1.8.2TablenbsDevPSTablenot-accessiblemandatoryThis table shows all the Power Supplies modules, existing in the corresponding Device.
1.3.6.1.4.1.629.1.50.11.1.8.2NodepowerSupplyUpThe SNMP trap that is generated when power supply unit changes it's state from notActive to active
1.3.6.1.4.1.629.1.50.11.1.8.2.1RownbsDevPSEntrynot-accessiblemandatoryThe entries of the table.
1.3.6.1.4.1.629.1.50.11.1.8.2.1.1ColumnnbsDevPSIndexread-onlymandatoryThe index of the table, (MAX Value is equal to nbsDevPSNumber).
1.3.6.1.4.1.629.1.50.11.1.8.2.1.2ColumnnbsDevPSTyperead-onlymandatoryThe physical Type of the Power Supply. acPS (2) - alternating current PS, dcPS (3) - dirrect current PS, externalPS (4) - external PS.
1.3.6.1.4.1.629.1.50.11.1.8.2.1.3ColumnnbsDevPSDescriptionread-onlymandatoryThe Text Decription of the Power Supply.
1.3.6.1.4.1.629.1.50.11.1.8.2.1.4ColumnnbsDevPSRedundantModeread-onlymandatoryThe working mode of the Power Supply.
1.3.6.1.4.1.629.1.50.11.1.8.2.1.5ColumnnbsDevPSOperStatusread-onlymandatoryThe Oper status of the Power Supply.
1.3.6.1.4.1.629.1.50.11.1.8.2.1.6ColumnnbsDevPSAdminStatusread-writemandatoryThe Admin status of the Power Supply.
1.3.6.1.4.1.629.1.50.11.1.8.3NodepowerSupplyDownThe SNMP trap that is generated when power supply unit changes it's state from active to notActive
1.3.6.1.4.1.629.1.50.11.1.8.4NodepowerSupplyPresentThe SNMP trap that is generated when power supply unit installed on device
1.3.6.1.4.1.629.1.50.11.1.8.5NodepowerSupplyNotPresentThe SNMP trap that is generated when power supply unit not installed on device
1.3.6.1.4.1.629.1.50.11.1.9NodenbsDevPSInput
1.3.6.1.4.1.629.1.50.11.1.9.1ScalarnbsDevPSInputNumberread-onlymandatoryThe number of Power Suppliy Inputs in the corresponding Device. Value = 0 says, that Power Supply Inputs Table is not supported.
1.3.6.1.4.1.629.1.50.11.1.9.2TablenbsDevPSInputTablenot-accessiblemandatoryThis table shows all the Power Supply Inputs, existing in the corresponding Device.
1.3.6.1.4.1.629.1.50.11.1.9.2.1RownbsDevPSInputEntrynot-accessiblemandatoryThe entries of the table.
1.3.6.1.4.1.629.1.50.11.1.9.2.1.1ColumnnbsDevPSInputIndexread-onlymandatoryThe index of the table, (MAX Value is equal to nbsDevPSInputNumber).
1.3.6.1.4.1.629.1.50.11.1.9.2.1.2ColumnnbsDevPSInputTyperead-onlymandatoryThe physical Type of the Power Supply. acInput (2) - alternating current input, dcInput (3) - direct current input, dcRedundInput (4) - direct current Redundan…
1.3.6.1.4.1.629.1.50.11.1.9.2.1.3ColumnnbsDevPSInputDescriptionread-onlymandatoryThe Text Decription of the Power Supply Input.
1.3.6.1.4.1.629.1.50.11.1.9.2.1.4ColumnnbsDevPSInputRedundantModeread-onlymandatoryThe Redundant mode of the Power Supply Input.
1.3.6.1.4.1.629.1.50.11.1.9.2.1.5ColumnnbsDevPSInputOperStatusread-onlymandatoryThe Oper status of the Power Supply Input.
1.3.6.1.4.1.629.1.50.11.1.9.2.1.6ColumnnbsDevPSInputAdminStatusread-writemandatoryThe Admin status of the Power Supply Input.
1.3.6.1.4.1.629.1.50.11.1.10NodenbsDevCPU
1.3.6.1.4.1.629.1.50.11.1.10.1ScalarnbsDevCPUNumberread-onlymandatoryThe number of CPU cards in the corresponding Device. Value = 0 says, that CPU Table is not supported.
1.3.6.1.4.1.629.1.50.11.1.10.2TablenbsDevCPUTablenot-accessiblemandatoryThis table shows all the CPU modules, existing in the corresponding Device.
1.3.6.1.4.1.629.1.50.11.1.10.2.1RownbsDevCPUEntrynot-accessiblemandatoryThe entries of the table.
1.3.6.1.4.1.629.1.50.11.1.10.2.1.1ColumnnbsDevCPUIndexread-onlymandatoryThe index of the table, (MAX Value is equal to nbsDevCPUNumber).
1.3.6.1.4.1.629.1.50.11.1.10.2.1.2ColumnnbsDevCPUTyperead-onlymandatoryThe physical Type of the CPU. - cx33cpu2MBflash16MBdram (2) CPU CX with 33Mhz clock,2MB Flash Memory and 16 MB DRAM Memory, - cx33cpu4MBflash16MBdram (2) CPU C…
1.3.6.1.4.1.629.1.50.11.1.10.2.1.3ColumnnbsDevCPUDescriptionread-onlymandatoryThe Text Decription of the CPU card.
1.3.6.1.4.1.629.1.50.11.1.10.2.1.4ColumnnbsDevCPURedundantModeread-onlymandatoryThe Redundant mode of the CPU card.
1.3.6.1.4.1.629.1.50.11.1.10.2.1.5ColumnnbsDevCPUOperStatusread-onlymandatoryThe Oper status of the CPU card.
1.3.6.1.4.1.629.1.50.11.1.10.2.1.6ColumnnbsDevCPUAdminStatusread-writemandatoryThe Admin status of the CPU card.
1.3.6.1.4.1.629.1.50.11.1.10.2.1.7ColumnnbsDevCPUOrderNumberread-onlymandatoryThe order number of the CPU card.
1.3.6.1.4.1.629.1.50.11.1.11NodenbsDevFAN
1.3.6.1.4.1.629.1.50.11.1.11.1ScalarnbsDevFANsNumberread-onlymandatoryThe number of FAN cards in the corresponding Device. Value = 0 says, that FAN Table is not supported.
1.3.6.1.4.1.629.1.50.11.1.11.2TablenbsDevFANTablenot-accessiblemandatoryThis table shows all the FAN modules, existing in the corresponding Device.
1.3.6.1.4.1.629.1.50.11.1.11.2.1RownbsDevFANEntrynot-accessiblemandatoryThe entries of the table.
1.3.6.1.4.1.629.1.50.11.1.11.2.1.1ColumnnbsDevFANIndexread-onlymandatoryThe index of the table, (MAX Value is equal to nbsDevFANsNumber).
1.3.6.1.4.1.629.1.50.11.1.11.2.1.2ColumnnbsDevFANTyperead-onlymandatoryThe physical Type of the FAN.
1.3.6.1.4.1.629.1.50.11.1.11.2.1.3ColumnnbsDevFANDescriptionread-onlymandatoryThe Text Decription of the FAN card.
1.3.6.1.4.1.629.1.50.11.1.11.2.1.5ColumnnbsDevFANOperStatusread-onlymandatoryThe Oper status of the FAN card.
1.3.6.1.4.1.629.1.50.11.1.11.2.1.6ColumnnbsDevFANAdminStatusread-writemandatoryThe Admin status of the FAN card.
1.3.6.1.4.1.629.1.50.11.1.11.2.1.7ColumnnbsDevFANSpeedread-onlymandatoryCurrent PWM fan speed (percent units)
1.3.6.1.4.1.629.1.50.11.1.11.46NodefanUnitUpThe SNMP trap that is generated when FAN unit changes it's state from notActive to active
1.3.6.1.4.1.629.1.50.11.1.11.47NodefanUnitDownThe SNMP trap that is generated when FAN unit changes it's state from active to notActive
1.3.6.1.4.1.629.1.50.11.1.12NodedeviceRCMredundancyStateGenerate SNMP trap when RCM Redundancy state of the device is changed.
1.3.6.1.4.1.629.1.50.11.1.12ScalarnbsDevHeaterStatusread-onlymandatoryThe Heater Status of Device.
1.3.6.1.4.1.629.1.50.11.1.13NodenbsDevPhysParams
1.3.6.1.4.1.629.1.50.11.1.13.1ScalarnbsDevPhParamDevAmbientTempCread-onlymandatoryThe Device Ambient Temperature [Celsius scale].
1.3.6.1.4.1.629.1.50.11.1.13.2ScalarnbsDevPhParamPackProcTempCread-onlymandatoryThe Device Packet Processor Temperature [Celsius scale].
1.3.6.1.4.1.629.1.50.11.1.13.3ScalarnbsDevPhParamCpuTempCread-onlymandatoryThe Device CPU Temperature [Celsius scale].
1.3.6.1.4.1.629.1.50.11.1.13.7ScalarnbsDevPhParamDevAmbientTempFread-onlymandatoryThe Device Ambient Temperature [Fahrenheit scale].
1.3.6.1.4.1.629.1.50.11.1.13.8ScalarnbsDevPhParamPackProcTempFread-onlymandatoryThe Device Packet Processor Temperature [Fahrenheit scale].
1.3.6.1.4.1.629.1.50.11.1.13.9ScalarnbsDevPhParamCpuTempFread-onlymandatoryThe Device CPU Temperature [Fahrenheit scale].
1.3.6.1.4.1.629.1.50.11.1.14NodenbsDevPSHost
1.3.6.1.4.1.629.1.50.11.1.14.1ScalarnbsDevPSHostsNumberread-onlymandatoryThe number of Power Supplies Hosts in the corresponding Device. Value = 0 says, that Power Supply Hosts Table is not supported.
1.3.6.1.4.1.629.1.50.11.1.14.2TablenbsDevPSHostTablenot-accessiblemandatoryThis table shows all the Power Supplies modules, existing in the corresponding Device.
1.3.6.1.4.1.629.1.50.11.1.14.2.1RownbsDevPSHostEntrynot-accessiblemandatoryThe entries of the table.
1.3.6.1.4.1.629.1.50.11.1.14.2.1.1ColumnnbsDevPSHostIndexread-onlymandatoryThe index of the table, (MAX Value is equal to nbsDevPSHostsNumber).
1.3.6.1.4.1.629.1.50.11.1.14.2.1.2ColumnnbsDevPSHostTyperead-onlymandatoryThe physical Type of the Power Supply Host. acPSHost (2) - alternating current PS, dcPSHost (3) - dirrect current PS.
1.3.6.1.4.1.629.1.50.11.1.14.2.1.3ColumnnbsDevPSHostDescrread-onlymandatoryThe Text Decription of the Power Supply Host.
1.3.6.1.4.1.629.1.50.11.1.14.2.1.4ColumnnbsDevPSHostPSNumberread-onlymandatoryPower Supplies Number in the Host.
1.3.6.1.4.1.629.1.50.11.1.14.2.1.6ColumnnbsDevPSHostFirstPSread-onlymandatoryNumber of the First Power Supply in the Host. according to the Power Supplies Numeration. in the nbsDevPSTable.
1.3.6.1.4.1.629.1.50.11.1.14.2.1.8ColumnnbsDevPSHostOperStatusread-onlymandatoryThe Oper status of the Power Supply Host.
1.3.6.1.4.1.629.1.50.11.1.14.2.1.10ColumnnbsDevPSHostAdminStatusread-writemandatoryThe Admin status of the Power Supply Host.
1.3.6.1.4.1.629.1.50.11.1.15ScalarnbsDevTemperatureProfileread-onlymandatoryThe Temperature profile of Device.
1.3.6.1.4.1.629.1.50.11.1.15ScalarnbsSysRomVersread-onlymandatoryThe SNMP Agent firmware Rom version
1.3.6.1.4.1.629.1.50.11.1.20NodesnmpAccessModeGenerate SNMP trap when SNMP Access mode of the device is changed.
1.3.6.1.4.1.629.1.50.11.1.21NodesnmpRequestRejectedGenerate SNMP trap when an SNMP Request is rejected due to SNMP Access Mode of the Device.
1.3.6.1.4.1.629.1.50.11.1.48NodedeviceTemperatureNormalThe SNMP trap that is generated when Device Temperature changes it's state from High to Normal
1.3.6.1.4.1.629.1.50.11.1.49NodedeviceTemperatureHighThe SNMP trap that is generated when Device Temperature changes it's state from Normal to High
1.3.6.1.4.1.629.1.50.11.1.50NodeAdminPasswdChangeThe SNMP trap that is generated when admin password is changed.
1.3.6.1.4.1.629.1.50.11.1.50NodenbsDevTrapVars
1.3.6.1.4.1.629.1.50.11.1.50.1ScalarnbsDevSessionTyperead-onlymandatoryThe type of the protocol session in use when the LOGIN password is invalidated.
1.3.6.1.4.1.629.1.50.11.1.50.2ScalarnbsDevAuthenticationRejectReasonread-onlymandatoryThe reason for the Authentication Error.
1.3.6.1.4.1.629.1.50.11.1.50.5ScalarnbsTrapLoginNameread-onlymandatoryThe Login User Name that creates wrong access.
1.3.6.1.4.1.629.1.50.11.1.50.6ScalarnbsTrapHostIpAddressread-onlymandatoryThe Remote Host Name (Ip Address or DNS Name) that attempts wrong access.
1.3.6.1.4.1.629.1.50.11.1.50.7ScalarnbsTrapWrongAccessDateTimeread-onlymandatoryThe Date / Time of the wrong access.
1.3.6.1.4.1.629.1.50.11.1.50.8ScalarnbsTrapRCMredundancyStateread-onlymandatoryRCM Redundancy State of device.
1.3.6.1.4.1.629.1.50.11.1.50.10ScalarnbsDevSNMPAccessModeread-onlymandatorySNMP access mode of device.
1.3.6.1.4.1.629.1.50.11.1.50.11ScalarnbsDeviceTrapReasonread-onlymandatoryThe reason of the coming TRAP.
1.3.6.1.4.1.629.1.50.11.1.50.12ScalarnbsDeviceTrapAdminPasswdChangeDescriptonread-onlymandatoryThe admin password change TRAP.