MIB Viewer

DKSF-60-4-X-X-X

104 objects
Generic MIB for NetPing remote sensing and control
Imported Objects
SNMPv2-MIBsnmpTraps
SNMPv2-SMICounter32 Counter64 enterprises Gauge32 Integer32 MODULE-IDENTITY NOTIFICATION-TYPE OBJECT-TYPE TimeTicks
SNMPv2-TCDisplayString TEXTUAL-CONVENTION TimeStamp TruthValue
OIDNameAccessStatusDescription
1.3.6.1.4.1.25728Nodelightcom
1.3.6.1.4.1.25728.50IdentitynetPingGeneric MIB for NetPing remote sensing and control
1.3.6.1.4.1.25728.911NodenpReboot
1.3.6.1.4.1.25728.911.1ScalarnpSoftRebootread-writecurrentWrite 1 to reboot device after current operations completition
1.3.6.1.4.1.25728.911.2ScalarnpResetStackread-writecurrentWrite 1 to re-initialize network stack
1.3.6.1.4.1.25728.911.3ScalarnpForcedRebootread-writecurrentWrite 1 to immediate forced reboot
1.3.6.1.4.1.25728.5500NodenpRelay
1.3.6.1.4.1.25728.5500.5TablenpRelayTablenot-accessiblecurrentWatchdog and outlet/relay control table
1.3.6.1.4.1.25728.5500.5.1RownpRelayEntrynot-accessiblecurrentRelay/outlet table row
1.3.6.1.4.1.25728.5500.5.1.1ColumnnpRelayNread-onlycurrentThe N of output relay
1.3.6.1.4.1.25728.5500.5.1.2ColumnnpRelayModeread-writecurrentControl of relay: 0 - manual off 1 - manual on 2 - watchdog 3 - schedule 4 - both schedule and watchdog (while switched on by schedule) 5 - logic
1.3.6.1.4.1.25728.5500.5.1.3ColumnnpRelayStartResetread-writecurrentWrite 1 to start reset (switch relay off for some time)
1.3.6.1.4.1.25728.5500.5.1.6ColumnnpRelayMemoread-onlycurrentRelay memo
1.3.6.1.4.1.25728.5500.5.1.14ColumnnpRelayFlipread-writecurrentWrite -1 to flip between manual on and manual off states of relay
1.3.6.1.4.1.25728.5500.5.1.15ColumnnpRelayStateread-onlycurrentActual relay state at the moment, regardless of source of control. 0 - relay is off 1 - relay is on
1.3.6.1.4.1.25728.5800NodenpPwr
1.3.6.1.4.1.25728.5800.3TablenpPwrTablenot-accessiblecurrentWatchdog and outlet/relay control table
1.3.6.1.4.1.25728.5800.3.1RownpPwrEntrynot-accessiblecurrentWatchdog and outlet/relay control table row
1.3.6.1.4.1.25728.5800.3.1.1ColumnnpPwrChannelNread-onlycurrentThe id of watchdog/power channel
1.3.6.1.4.1.25728.5800.3.1.2ColumnnpPwrStartResetread-writecurrentWrite 1 to start forced reset On read: 0 - normal operation 1 - reset is active 2 - reboot pause is active or watchdog is inactive
1.3.6.1.4.1.25728.5800.3.1.3ColumnnpPwrManualModeread-writecurrentMode of power channel 0 - manual off 1 - manual on 2 - watchdog 3 - schedule 4 - schedule and watchdog 5 - controlled by Logic
1.3.6.1.4.1.25728.5800.3.1.4ColumnnpPwrResetsCounterread-writecurrentCounter of watchdog resets Write 0 to clear.
1.3.6.1.4.1.25728.5800.3.1.5ColumnnpPwrRepeatingResetsCounterread-onlycurrentCounter of continous failed watchdog resets
1.3.6.1.4.1.25728.5800.3.1.6ColumnnpPwrMemoread-onlycurrentRelay channel memo
1.3.6.1.4.1.25728.5800.3.1.14ColumnnpPwrRelayFlipread-writecurrentWrite -1 to flip between manual on and manual off states of relay
1.3.6.1.4.1.25728.5800.3.1.15ColumnnpPwrRelayStateread-onlycurrentActual relay state at the moment, regardless of source of control. 0 - relay is off 1 - relay is on
1.3.6.1.4.1.25728.7900NodenpIr
1.3.6.1.4.1.25728.7900.1NodenpIrCtrl
1.3.6.1.4.1.25728.7900.1.1ScalarnpIrPlayCmdread-writecurrentWrite IR command number to send IR command
1.3.6.1.4.1.25728.7900.1.2ScalarnpIrResetread-writecurrentWrite 1 to reset IR transiever. After reset, send IR command and check npIrStatus.
1.3.6.1.4.1.25728.7900.1.3ScalarnpIrStatusread-onlycurrentIR transiever status
1.3.6.1.4.1.25728.8300NodenpCurLoop
1.3.6.1.4.1.25728.8300.1TablenpCurLoopTablenot-accessiblecurrentCurrent loop sensors Table
1.3.6.1.4.1.25728.8300.1.1RownpCurLoopEntrynot-accessiblecurrentCurrent loop sensors Table Row
1.3.6.1.4.1.25728.8300.1.1.1ColumnnpCurLoopNread-onlycurrentIndex of current loop, 1 to max supported
1.3.6.1.4.1.25728.8300.1.1.2ColumnnpCurLoopStatusread-onlycurrentStatus of the loop 0=Normal, 1=Alert, 2=Cut, 3=Short, 4=Not Powered
1.3.6.1.4.1.25728.8300.1.1.3ColumnnpCurLoopIread-onlycurrentLoop current, mA
1.3.6.1.4.1.25728.8300.1.1.4ColumnnpCurLoopVread-onlycurrentVoltage drop on the loop, mV
1.3.6.1.4.1.25728.8300.1.1.5ColumnnpCurLoopRread-onlycurrentResistance of the loop, Ohm
1.3.6.1.4.1.25728.8300.1.1.7ColumnnpCurLoopPowerread-writecurrentControl of loop power 0=Off, 1=On, 2=reset by off/on power
1.3.6.1.4.1.25728.8300.2NodenpCurLoopTraps
1.3.6.1.4.1.25728.8300.2.0NodenpCurLoopTrapPrefix
1.3.6.1.4.1.25728.8300.2.0.1NotificationnpCurLoopTrapcurrentStatus of current loop N has changed!
1.3.6.1.4.1.25728.8300.2.1ScalarnpCurLoopTrapNread-onlycurrentIndex of current loop, which status has changed
1.3.6.1.4.1.25728.8300.2.2ScalarnpCurLoopTrapStatusread-onlycurrentStatus of the loop 0=Normal, 1=Alert, 2=Cut, 3=Short, 4=Not Powered
1.3.6.1.4.1.25728.8300.2.3ScalarnpCurLoopTrapIread-onlycurrentLoop current, mA
1.3.6.1.4.1.25728.8300.2.4ScalarnpCurLoopTrapVread-onlycurrentVoltage drop on the loop, mV
1.3.6.1.4.1.25728.8300.2.5ScalarnpCurLoopTrapRread-onlycurrentResistance of the loop, Ohm
1.3.6.1.4.1.25728.8300.2.7ScalarnpCurLoopTrapPowerread-writecurrentStatus of loop power 0=Off, 1=On
1.3.6.1.4.1.25728.8400NodenpRelHumidity
1.3.6.1.4.1.25728.8400.2NodenpRelHumSensor
1.3.6.1.4.1.25728.8400.2.2ScalarnpRelHumSensorValueHread-onlycurrentRelative humidity value, %
1.3.6.1.4.1.25728.8400.2.3ScalarnpRelHumSensorStatusread-onlycurrentStatus of the Rel.Humidity Sensor One 0=Normal, 1=Error or Sensor isn't connected
1.3.6.1.4.1.25728.8400.2.4ScalarnpRelHumSensorValueTread-onlycurrentSensor temperature, deg.C
1.3.6.1.4.1.25728.8400.2.5ScalarnpRelHumSensorStatusHread-onlycurrentStatus of Relative Humiduty
1.3.6.1.4.1.25728.8400.2.7ScalarnpRelHumSafeRangeHighread-onlycurrentRelative Humidity safe range, top margin, %RH
1.3.6.1.4.1.25728.8400.2.8ScalarnpRelHumSafeRangeLowread-onlycurrentRelative Humidity safe range, bottom margin, %RH
1.3.6.1.4.1.25728.8400.2.9ScalarnpRelHumSensorValueT100read-onlycurrentSensor temperature, deg.C * 100 (fixed point two decimal places) Used to get access to the fractional part of T value
1.3.6.1.4.1.25728.8400.9NodenpRelHumTraps
1.3.6.1.4.1.25728.8400.9.0NodenpRelHumTrapPrefix
1.3.6.1.4.1.25728.8400.9.0.1NotificationnpRelHumTrapcurrentStatus of Relative Humidity RH sensor has changed!
1.3.6.1.4.1.25728.8800NodenpThermo
1.3.6.1.4.1.25728.8800.1TablenpThermoTablenot-accessiblecurrentThermo Sensors Table
1.3.6.1.4.1.25728.8800.1.1RownpThermoEntrynot-accessiblecurrentThermo Sensors Table Row
1.3.6.1.4.1.25728.8800.1.1.1ColumnnpThermoSensorNread-onlycurrentThe id of temperature sensor, 1 to 8
1.3.6.1.4.1.25728.8800.1.1.2ColumnnpThermoValueread-onlycurrentTemperature, deg.C
1.3.6.1.4.1.25728.8800.1.1.3ColumnnpThermoStatusread-onlycurrentTemperature status (0=fault, 1=underheat, 2=normal, 3=overheat)
1.3.6.1.4.1.25728.8800.1.1.4ColumnnpThermoLowread-onlycurrentBottom margin of normal temperature range, deg.C
1.3.6.1.4.1.25728.8800.1.1.5ColumnnpThermoHighread-onlycurrentTop margin of normal temperature range, deg.C
1.3.6.1.4.1.25728.8800.1.1.6ColumnnpThermoMemoread-onlycurrentT channel memo
1.3.6.1.4.1.25728.8800.2NodenpThermoTraps
1.3.6.1.4.1.25728.8800.2.0NodenpThermoTrapPrefix
1.3.6.1.4.1.25728.8800.2.0.1NotificationnpThermoTrapcurrentStatus of Thermo sensor is changed (crossing of normal temp. range)
1.3.6.1.4.1.25728.8800.2.1ScalarnpThermoTrapSensorNread-onlycurrentThe id of temperature sensor, 1 to 8
1.3.6.1.4.1.25728.8800.2.2ScalarnpThermoTrapValueread-onlycurrentTemperature, deg.C
1.3.6.1.4.1.25728.8800.2.3ScalarnpThermoTrapStatusread-onlycurrentTemperature status (0=fault, 1=underheat, 2=normal, 3=overheat)
1.3.6.1.4.1.25728.8800.2.4ScalarnpThermoTrapLowread-onlycurrentBottom margin of normal temperature range, deg.C
1.3.6.1.4.1.25728.8800.2.5ScalarnpThermoTrapHighread-onlycurrentTop margin of normal temperature range, deg.C
1.3.6.1.4.1.25728.8800.2.6ScalarnpThermoTrapMemoread-onlycurrentT channel memo
1.3.6.1.4.1.25728.8900NodenpIo
1.3.6.1.4.1.25728.8900.1TablenpIoTablenot-accessiblecurrentDigital Input/output Table
1.3.6.1.4.1.25728.8900.1.1RownpIoEntrynot-accessiblecurrentDigital Input/output Table Row
1.3.6.1.4.1.25728.8900.1.1.1ColumnnpIoLineNread-onlycurrentNumber of IO line, from 1 to max supported
1.3.6.1.4.1.25728.8900.1.1.2ColumnnpIoLevelInread-onlycurrentInput level, 0 or 1
1.3.6.1.4.1.25728.8900.1.1.3ColumnnpIoLevelOutread-writecurrentOutput level, 0 or 1. Write -1 to flip output.
1.3.6.1.4.1.25728.8900.1.1.6ColumnnpIoMemoread-onlycurrentIO line memo
1.3.6.1.4.1.25728.8900.1.1.9ColumnnpIoPulseCounterread-writecurrentPulse Counter on IO input line (counts positive fronts) Write 0 to reset.
1.3.6.1.4.1.25728.8900.1.1.12ColumnnpIoSinglePulseDurationread-writecurrentSet duration of single pulse on IO output line, 100ms to 25500ms, min. step is 100ms
1.3.6.1.4.1.25728.8900.1.1.13ColumnnpIoSinglePulseStartread-writecurrentWrite 1 to start single pulse on IO output. Output will be inverted for time, specified by npIoSinglePulseDuration
1.3.6.1.4.1.25728.8900.2NodenpIoTraps
1.3.6.1.4.1.25728.8900.2.0NodenpIoTrapPrefix
1.3.6.1.4.1.25728.8900.2.0.1NotificationnpIoTrapcurrentInput state of IO line is changed
1.3.6.1.4.1.25728.8900.2.1ScalarnpIoTrapLineNread-onlycurrentTrap data, Number of IO line
1.3.6.1.4.1.25728.8900.2.2ScalarnpIoTrapLevelInread-onlycurrentTrap data, new Input level, 0 or 1
1.3.6.1.4.1.25728.8900.2.6ScalarnpIoTrapMemoread-onlycurrentTrap data, IO line memo
1.3.6.1.4.1.25728.8900.2.7ScalarnpIoTrapLevelLegendread-onlycurrentLegend for current logic level on the IO line
1.3.6.1.4.1.25728.9700NodenpElecMeter
1.3.6.1.4.1.25728.9700.1TablenpElecTablenot-accessiblecurrentElectricity Meter Table
1.3.6.1.4.1.25728.9700.1.1RownpElecEntrynot-accessiblecurrentElectricity Meter Table Table Row
1.3.6.1.4.1.25728.9700.1.1.1ColumnnpElecIndexread-onlycurrentNumber of elec.meter, associated with IO line
1.3.6.1.4.1.25728.9700.1.1.2ColumnnpElecPulsesPerKwhread-writecurrentPulses on IO line input per 1 kWh of consumed energy
1.3.6.1.4.1.25728.9700.1.1.3ColumnnpElecPowerread-onlycurrentPower, Watts, based on pulse rate/interval, 5 minute average
1.3.6.1.4.1.25728.9700.1.1.4ColumnnpElecEnergyread-writecurrentEnergy counter, kWh, based on pulse count
1.3.6.1.4.1.25728.9700.1.1.5ColumnnpElecEnergy100read-writecurrentEnergy counter, kWh*100, based on pulse count