DLINKPRIME-LBD-MIB
23 objects
This MIB module defines objects for loopback detection.
Imported Objects
| DLINK-ID-REC-MIB | dlinkPrimeCommon |
| IF-MIB | InterfaceIndex |
| Q-BRIDGE-MIB | VlanId |
| SNMPv2-CONF | MODULE-COMPLIANCE OBJECT-GROUP |
| SNMPv2-SMI | MODULE-IDENTITY NOTIFICATION-TYPE OBJECT-TYPE |
| SNMPv2-TC | DisplayString TruthValue |
| OID | Name | Access | Status | Description |
|---|---|---|---|---|
| 1.3.6.1.4.1.171.15.7 | IdentitydlinkPrimeLoopbackDetectMIB | This MIB module defines objects for loopback detection. | ||
| 1.3.6.1.4.1.171.15.7.0 | NodedpLbdNotifications | |||
| 1.3.6.1.4.1.171.15.7.0.1 | NotificationdpLbdLoopOccurred | current | This trap is sent when an interface loop occurs. | |
| 1.3.6.1.4.1.171.15.7.0.2 | NotificationdpLbdLoopRecovery | current | This trap is sent when an interface loop recovery. | |
| 1.3.6.1.4.1.171.15.7.1 | NodedpLbdObjects | |||
| 1.3.6.1.4.1.171.15.7.1.1 | ScalardpLbdCtrlGlobalEnabled | read-write | current | This object indicates whether the loopback detection is enabled globally. |
| 1.3.6.1.4.1.171.15.7.1.2 | ScalardpLbdCtrlInterval | read-write | current | This object indicates the interval in seconds at which LBD packets are transmitted. |
| 1.3.6.1.4.1.171.15.7.1.3 | ScalardpLbdCtrlRecover | read-write | current | This object indicates the recover in seconds after which LBD interface shutdown. |
| 1.3.6.1.4.1.171.15.7.1.4 | ScalardpLbdNotifyEnabled | read-write | current | Set to 'true' to enable global SNMP notification for loopback detection feature. Setting the object to 'false' will disable SNMP notifications. |
| 1.3.6.1.4.1.171.15.7.1.5 | TabledpLbdIfCfgTable | not-accessible | current | A list of loopback detection information entries. |
| 1.3.6.1.4.1.171.15.7.1.5.1 | RowdpLbdIfCfgEntry | not-accessible | current | An entry indicates the setting of loopback detection on an interface. |
| 1.3.6.1.4.1.171.15.7.1.5.1.1 | ColumndpLbdIfCfgIndex | not-accessible | current | This object indicates the ifIndex of the physical port or port channel. |
| 1.3.6.1.4.1.171.15.7.1.5.1.2 | ColumndpLbdIfCfgEnabled | read-write | current | This object indicates whether the loopback detection is enabled on the interface. |
| 1.3.6.1.4.1.171.15.7.1.5.1.3 | ColumndpLbdIfLoopStatus | read-only | current | This object indicates whether the interface loopback status. |
| 1.3.6.1.4.1.171.15.7.1.8 | IdentitydpLbdNotifyInfo | current | This identifier is a group for variable bindings for traps. | |
| 1.3.6.1.4.1.171.15.7.1.8.1 | ScalardpLbdNotifyInfoIfIndex | accessible-for-notify | current | This object indicates the interface id that has detected a loopback. |
| 1.3.6.1.4.1.171.15.7.2 | NodedpLbdConformance | |||
| 1.3.6.1.4.1.171.15.7.2.1 | NodedpLbdMIBCompliances | |||
| 1.3.6.1.4.1.171.15.7.2.1.1 | CompliancedpLbdMIBCompliance | current | The compliance statement for entities which implement the DLINKPRIME-LBD-MIB. | |
| 1.3.6.1.4.1.171.15.7.2.2 | NodedpLbdMIBGroups | |||
| 1.3.6.1.4.1.171.15.7.2.2.1 | GroupdpLbdCfgGroup | current | A collection of objects providing management of the loopback detection feature. | |
| 1.3.6.1.4.1.171.15.7.2.2.2 | GroupdpLbdIfCfgGroup | current | A collection of objects providing the per-interface control of loopback detection. | |
| 1.3.6.1.4.1.171.15.7.2.2.3 | GroupdpLbdNotificationGroup | current | A collection of notifications used for monitoring the hosts under the control of loopback detection. |