MIB Viewer

DLINKSW-ENTITY-EXT-MIB

76 objects
This MIB module provides essential information about the system and defines the managed objects that support the monitoring of alarms generated by physical entities, including temperature sensors, fans and power supplies.
Imported Objects
DLINK-ID-REC-MIBdlinkIndustrialCommon
SNMPv2-CONFMODULE-COMPLIANCE NOTIFICATION-GROUP OBJECT-GROUP
SNMPv2-SMIInteger32 MODULE-IDENTITY NOTIFICATION-TYPE OBJECT-TYPE Unsigned32
SNMPv2-TCDisplayString
OIDNameAccessStatusDescription
1.3.6.1.4.1.171.14.5IdentitydlinkSwEntityExtMIBThis MIB module provides essential information about the system and defines the managed objects that support the monitoring of alarms generated by physical ent…
1.3.6.1.4.1.171.14.5.0NodedEntityExtNotifications
1.3.6.1.4.1.171.14.5.0.1NotificationdEntityExtFanStatusChgcurrentThis trap indicates a fan fails (dEntityExtEnvFanStatus is 'fault') or recovers (dEntityExtEnvFanStatus is 'ok').
1.3.6.1.4.1.171.14.5.0.2NotificationdEntityExtThermalStatusChgcurrentThis trap indicates a thermal alarms (dEntityExtEnvTempStatus is 'abnormal') or recovers (dEntityExtEnvTempStatus is 'ok').
1.3.6.1.4.1.171.14.5.0.3NotificationdEntityExtPowerStatusChgcurrentThis trap indicates a power module fails, recovers or is removed.
1.3.6.1.4.1.171.14.5.0.4NotificationdEntityExtAirFlowChgcurrentThis trap is triggered when the air flow status is changed from 'ok' to 'abnormal' and vice versa. dEntityExtEnvAirFlowStatus indicates the current (new) fan a…
1.3.6.1.4.1.171.14.5.0.5NotificationdEntityExtFactoryResetButtoncurrentThis trap is triggered when the factory reset button was pressed.
1.3.6.1.4.1.171.14.5.1NodedEntityExtObjects
1.3.6.1.4.1.171.14.5.1.1NodedEntityExtEnvObjects
1.3.6.1.4.1.171.14.5.1.1.1TabledEntityExtEnvTempTablenot-accessiblecurrentThe table consists of a list of temperature information.
1.3.6.1.4.1.171.14.5.1.1.1.1RowdEntityExtEnvTempEntrynot-accessiblecurrentAn entry represents the temperature status of a testpoint.
1.3.6.1.4.1.171.14.5.1.1.1.1.1ColumndEntityExtEnvTempUnitIdnot-accessiblecurrentThis object indicates the unit (stacking device) or slot (chassis device) ID at which the testpoint is located.
1.3.6.1.4.1.171.14.5.1.1.1.1.2ColumndEntityExtEnvTempIndexnot-accessiblecurrentThis object is used to uniquely identify the testpoint within a unit/slot. This index is for SNMP purposes only, and has no intrinsic meaning.
1.3.6.1.4.1.171.14.5.1.1.1.1.3ColumndEntityExtEnvTempDescrread-onlycurrentThis object provides human-sensible identification for the testpoint. e.g. 'Inlet', 'Center', 'Outlet'.
1.3.6.1.4.1.171.14.5.1.1.1.1.4ColumndEntityExtEnvTempCurrentread-onlycurrentThis object indicates the current measurement of the testpoint.
1.3.6.1.4.1.171.14.5.1.1.1.1.5ColumndEntityExtEnvTempThresholdLowread-writecurrentThe object indicates the minimum acceptable reading of the testpoint in degrees Celsius.
1.3.6.1.4.1.171.14.5.1.1.1.1.6ColumndEntityExtEnvTempThresholdHighread-writecurrentThe object indicates the maximum acceptable reading of the testpoint in degrees Celsius.
1.3.6.1.4.1.171.14.5.1.1.1.1.7ColumndEntityExtEnvTempStatusread-onlycurrentThe object indicates the current temperature is over the thresholds or not. 'abnormal' indicates the temperature is over the thresholds. 'ok' indicates the tem…
1.3.6.1.4.1.171.14.5.1.1.2TabledEntityExtEnvFanTablenot-accessiblecurrentThe table is used to display the status of fans.
1.3.6.1.4.1.171.14.5.1.1.2.1RowdEntityExtEnvFanEntrynot-accessiblecurrentAn entry represents a fan status.
1.3.6.1.4.1.171.14.5.1.1.2.1.1ColumndEntityExtEnvFanUnitIdnot-accessiblecurrentThis object indicates the unit (stacking device) or slot (chassis device) ID at which the fan is located.
1.3.6.1.4.1.171.14.5.1.1.2.1.2ColumndEntityExtEnvFanIndexnot-accessiblecurrentThis object is used to uniquely identify the fan within a unit/slot. This index is for SNMP purposes only, and has no intrinsic meaning.
1.3.6.1.4.1.171.14.5.1.1.2.1.3ColumndEntityExtEnvFanDescrread-onlycurrentThis object provides human-sensible identification for the fan. e.g. 'Left 1' for the first fan on the left.
1.3.6.1.4.1.171.14.5.1.1.2.1.4ColumndEntityExtEnvFanStatusread-onlycurrentThis object indicates the fan status.
1.3.6.1.4.1.171.14.5.1.1.3TabledEntityExtEnvPowerTablenot-accessiblecurrentThe table is used to display the status of the power modules.
1.3.6.1.4.1.171.14.5.1.1.3.1RowdEntityExtEnvPowerEntrynot-accessiblecurrentAn entry contains the information of a power module.
1.3.6.1.4.1.171.14.5.1.1.3.1.1ColumndEntityExtEnvPowerUnitIdnot-accessiblecurrentThis object indicates the unit (stacking device) or slot (chassis device) ID at which the power module is located.
1.3.6.1.4.1.171.14.5.1.1.3.1.2ColumndEntityExtEnvPowerIndexnot-accessiblecurrentThis object indicates the ID of the power module. This object is used to uniquely identify the power module. This index is for SNMP purposes only, and has no i…
1.3.6.1.4.1.171.14.5.1.1.3.1.3ColumndEntityExtEnvPowerDescrread-onlycurrentThis object provides human-sensible information for the power module. e.g. '#1 (internal)', '#2 (external)'.
1.3.6.1.4.1.171.14.5.1.1.3.1.4ColumndEntityExtEnvPowerUsedPowerread-onlycurrentThis object indicates the amount of the power that has been allocated.
1.3.6.1.4.1.171.14.5.1.1.3.1.5ColumndEntityExtEnvPowerMaxPowerread-onlycurrentThis object indicates maximum power which the power module can supply.
1.3.6.1.4.1.171.14.5.1.1.3.1.6ColumndEntityExtEnvPowerStatusread-onlycurrentThis object indicates the status of the power.
1.3.6.1.4.1.171.14.5.1.1.4TabledEntityExtEnvAirFlowTablenot-accessiblecurrentThe table is used to display the status of the air flow function.
1.3.6.1.4.1.171.14.5.1.1.4.1RowdEntityExtEnvAirFlowEntrynot-accessiblecurrentAn entry contains the information of the air flow function.
1.3.6.1.4.1.171.14.5.1.1.4.1.1ColumndEntityExtEnvAirFlowUnitIdnot-accessiblecurrentThis object indicates the unit (stacking device) or slot (chassis device) ID at which the air flow module is located.
1.3.6.1.4.1.171.14.5.1.1.4.1.2ColumndEntityExtEnvAirFlowStatusread-onlycurrentThis object indicates the status of the air flow. The fans' air flow direction must match the system's air flow direction to form an integrated air flow. For e…
1.3.6.1.4.1.171.14.5.1.2NodedEntityExtEnvTrap
1.3.6.1.4.1.171.14.5.1.2.1ScalardEntityExtEnvNotifyEnableread-writecurrentThis object indicates whether a specified notification is enabled or not. If a bit corresponding to a notification is set to 1, then the specified notification…
1.3.6.1.4.1.171.14.5.1.3TabledEntityExtUnitTablenot-accessiblecurrentThe table is used to display information of units.
1.3.6.1.4.1.171.14.5.1.3.1RowdEntityExtUnitEntrynot-accessiblecurrentAn entry contains essential information of a unit.
1.3.6.1.4.1.171.14.5.1.3.1.1ColumndEntityExtUnitIndexnot-accessiblecurrentThis object indicates the unit (stacking device) or slot (chassis device) ID.
1.3.6.1.4.1.171.14.5.1.3.1.2ColumndEntityExtUnitStatusread-onlycurrentThis object represents the status of the unit: ok(1) - This indicates the unit is okay. failed(2) - This indicates the unit fails due to some reason. empty(3) …
1.3.6.1.4.1.171.14.5.1.3.1.3ColumndEntityExtUnitUpTimeread-onlycurrentThis object provides the up time in units of seconds for the unit since it was last re-initialized.
1.3.6.1.4.1.171.14.5.1.4TabledEntityExtMemoryUtilTablenot-accessiblecurrentThe table is used to display memory utilization information.
1.3.6.1.4.1.171.14.5.1.4.1RowdEntityExtMemoryUtilEntrynot-accessiblecurrentAn entry contains memory utilization information.
1.3.6.1.4.1.171.14.5.1.4.1.1ColumndEntityExtMemUtilUnitIdnot-accessiblecurrentThis object indicates the unit (stacking device) or slot (chassis device) ID.
1.3.6.1.4.1.171.14.5.1.4.1.2ColumndEntityExtMemUtilTypenot-accessiblecurrentThe object indicates the memory type of the entry.
1.3.6.1.4.1.171.14.5.1.4.1.3ColumndEntityExtMemUtilTotalread-onlycurrentThis object indicates the total memory size of the entry.
1.3.6.1.4.1.171.14.5.1.4.1.4ColumndEntityExtMemUtilUsedread-onlycurrentThis object indicates the used memory size of the entry.
1.3.6.1.4.1.171.14.5.1.4.1.5ColumndEntityExtMemUtilFreeread-onlycurrentThis object indicates the free memory size of the entry.
1.3.6.1.4.1.171.14.5.1.7TabledEntityExtCpuUtilTablenot-accessiblecurrentThe table is used to display CPU utilization information.
1.3.6.1.4.1.171.14.5.1.7.1RowdEntityExtCpuUtilEntrynot-accessiblecurrentAn entry contains CPU information.
1.3.6.1.4.1.171.14.5.1.7.1.1ColumndEntityExtCpuUtilUnitIdnot-accessiblecurrentThis object indicates the unit (stacking device) or slot (chassis device) ID.
1.3.6.1.4.1.171.14.5.1.7.1.2ColumndEntityExtCpuUtilCpuIDnot-accessiblecurrentThis object is used to uniquely identify the CPU within a unit (multiprocessing system).
1.3.6.1.4.1.171.14.5.1.7.1.3ColumndEntityExtCpuUtilFiveSecondsread-onlycurrentThis objects indicates the overall CPU busy percentage in the last 5 second period. The value will be between 0% (idle) and 100% (very busy).
1.3.6.1.4.1.171.14.5.1.7.1.4ColumndEntityExtCpuUtilOneMinuteread-onlycurrentThis objects indicates the overall CPU busy percentage in the last 1 minute period. The value will be between 0% (idle) and 100% (very busy).
1.3.6.1.4.1.171.14.5.1.7.1.5ColumndEntityExtCpuUtilFiveMinutesread-onlycurrentThis objects indicates the overall CPU busy percentage in the last 5 minute period. The value will be between 0% (idle) and 100% (very busy).
1.3.6.1.4.1.171.14.5.1.8TabledEntityExtVersionTablenot-accessiblecurrentThe table is used to display version information of units.
1.3.6.1.4.1.171.14.5.1.8.1RowdEntityExtVersionEntrynot-accessiblecurrentAn entry contains version information of a unit.
1.3.6.1.4.1.171.14.5.1.8.1.1ColumndEntityExtVersionUnitIdnot-accessiblecurrentThis object indicates the unit (stacking device) or slot (chassis device) ID.
1.3.6.1.4.1.171.14.5.1.8.1.2ColumndEntityExtVersionBootloaderread-onlycurrentThis object indicates the bootloader version of the unit.
1.3.6.1.4.1.171.14.5.1.8.1.3ColumndEntityExtVersionRuntimeread-onlycurrentThis object indicates the firmware version of one unit.
1.3.6.1.4.1.171.14.5.2NodedEntityExtConformance
1.3.6.1.4.1.171.14.5.2.1NodedEntityExtMIBCompliances
1.3.6.1.4.1.171.14.5.2.1.1CompliancedEntityExtComplianceread-onlycurrentThe compliance statement for entities which implement the DLINKSW-ENTITY-EXT-MIB.
1.3.6.1.4.1.171.14.5.2.2NodedEntityExtMIBGroups
1.3.6.1.4.1.171.14.5.2.2.1GroupdEntityExtTempGroupcurrentA collection of objects provides information of the system temperature.
1.3.6.1.4.1.171.14.5.2.2.2GroupdEntityExtFanGroupcurrentA collection of objects providing informations of fans.
1.3.6.1.4.1.171.14.5.2.2.3GroupdEntityExtPowerGroupcurrentA collection of objects providing information of power modules.
1.3.6.1.4.1.171.14.5.2.2.4GroupdEntityExtSystemInfoGroupcurrentA collection of objects provides information of the system temperature.
1.3.6.1.4.1.171.14.5.2.2.5GroupdEntityExtGenericNotifInfoGroupcurrentA collection of objects provides generic information for binding variables of notification.
1.3.6.1.4.1.171.14.5.2.2.6GroupdEntityExtFanNotifGroupcurrentA collection of notifications for indicating the status change of fans.
1.3.6.1.4.1.171.14.5.2.2.7GroupdEntityExtThermalNotifGroupcurrentA collection of notifications for indicating the status change of thermals.
1.3.6.1.4.1.171.14.5.2.2.8GroupdEntityExtPowerNotifGroupcurrentA collection of notifications for indicating the status change of power module.
1.3.6.1.4.1.171.14.5.2.2.9GroupdEntityExtAirFlowNotifGroupcurrentA collection of notifications for indicating the status change of the air flow.
1.3.6.1.4.1.171.14.5.2.2.10GroupdEntityExtFactoryResetButtonNotifGroupcurrentA collection of notifications for indicating the factory reset button.