DNS-340L-MIB
42 objects
No module-level DESCRIPTION found.
Imported Objects
| SNMPv2-SMI | enterprises Integer32 NOTIFICATION-TYPE OBJECT-TYPE |
| SNMPv2-TC | DisplayString |
| OID | Name | Access | Status | Description |
|---|---|---|---|---|
| 1.3.6.1.4.1.171 | Noded-link | |||
| 1.3.6.1.4.1.171.50 | NodeproductID | |||
| 1.3.6.1.4.1.171.50.1 | NodeprojectID | |||
| 1.3.6.1.4.1.171.50.1.10 | NodemodelID | |||
| 1.3.6.1.4.1.171.50.1.10.1 | NodesubmodelID | |||
| 1.3.6.1.4.1.171.50.1.10.1.1 | NodenasAgent | |||
| 1.3.6.1.4.1.171.50.1.10.1.1.1 | Scalardns340LAgentVer | read-only | current | Version information for the agent of SNMP of DNS-340L. |
| 1.3.6.1.4.1.171.50.1.10.1.1.2 | Scalardns340LSoftwareVersion | read-only | current | The device software version. |
| 1.3.6.1.4.1.171.50.1.10.1.1.3 | Scalardns340LHostName | read-only | current | The device host name. |
| 1.3.6.1.4.1.171.50.1.10.1.1.5 | Scalardns340LFTPServer | read-only | current | Ftp Server status. (Disable/Enable) |
| 1.3.6.1.4.1.171.50.1.10.1.1.6 | Scalardns340LNetType | read-only | current | The Network type. (Workgroup/Active Directory) |
| 1.3.6.1.4.1.171.50.1.10.1.1.7 | Scalardns340LTemperature | read-only | current | The temperature of the system. |
| 1.3.6.1.4.1.171.50.1.10.1.1.8 | Scalardns340LFanStatus | read-only | current | The status of the fan |
| 1.3.6.1.4.1.171.50.1.10.1.1.9 | Tabledns340LVolumeTable | not-accessible | current | A table of active volumes on the NAS device. |
| 1.3.6.1.4.1.171.50.1.10.1.1.9.1 | Rowdns340LVolumeEntry | not-accessible | current | An entry in the volume table. |
| 1.3.6.1.4.1.171.50.1.10.1.1.9.1.1 | Columndns340LVolumeNum | read-only | current | Instance number of the volume entry. |
| 1.3.6.1.4.1.171.50.1.10.1.1.9.1.2 | Columndns340LVolumeName | read-only | current | The name of the volume. |
| 1.3.6.1.4.1.171.50.1.10.1.1.9.1.3 | Columndns340LVolumeFsType | read-only | current | The type of file system of the volume. Example : ext3 or ext4 |
| 1.3.6.1.4.1.171.50.1.10.1.1.9.1.4 | Columndns340LVolumeRaidLevel | read-only | current | The RAID level of the volume. (STANDARD LINEAR RAID0 RAID1 RAID5 RAID10 RAID5+SPARE) |
| 1.3.6.1.4.1.171.50.1.10.1.1.9.1.5 | Columndns340LVolumeSize | read-only | current | The size of the volume in bytes. |
| 1.3.6.1.4.1.171.50.1.10.1.1.9.1.6 | Columndns340LVolumeFreeSpace | read-only | current | Free space on the volume in bytes. |
| 1.3.6.1.4.1.171.50.1.10.1.1.10 | Tabledns340LDiskTable | not-accessible | current | A table of physical disks attached to the NAS device. |
| 1.3.6.1.4.1.171.50.1.10.1.1.10.1 | Rowdns340LDiskEntry | not-accessible | current | An entry in the physical disk table. |
| 1.3.6.1.4.1.171.50.1.10.1.1.10.1.1 | Columndns340LDiskNum | read-only | current | Instance number of the disk entry. |
| 1.3.6.1.4.1.171.50.1.10.1.1.10.1.2 | Columndns340LDiskVendor | read-only | current | The vendor of the disk drive. |
| 1.3.6.1.4.1.171.50.1.10.1.1.10.1.3 | Columndns340LDiskModel | read-only | current | The disk drive's model name. |
| 1.3.6.1.4.1.171.50.1.10.1.1.10.1.4 | Columndns340LDiskSerialNumber | read-only | current | The disk drive's serial number. |
| 1.3.6.1.4.1.171.50.1.10.1.1.10.1.5 | Columndns340LDiskTemperature | read-only | current | The centigrade temperature of this disk. |
| 1.3.6.1.4.1.171.50.1.10.1.1.10.1.6 | Columndns340LDiskCapacity | read-only | current | The capacity of the disk in GB. |
| 1.3.6.1.4.1.171.50.1.10.1.1.11 | Tabledns340LUPSTable | not-accessible | current | A table of UPS attached to the NAS device. |
| 1.3.6.1.4.1.171.50.1.10.1.1.11.1 | Rowdns340LUPSEntry | not-accessible | current | An entry in the UPS table. |
| 1.3.6.1.4.1.171.50.1.10.1.1.11.1.1 | Columndns340LUPSNum | read-only | current | Instance number of the UPS entry. |
| 1.3.6.1.4.1.171.50.1.10.1.1.11.1.2 | Columndns340LUPSMode | read-only | current | The mode of the UPS |
| 1.3.6.1.4.1.171.50.1.10.1.1.11.1.3 | Columndns340LUPSManufacturer | read-only | current | The manufacturer of the UPS. |
| 1.3.6.1.4.1.171.50.1.10.1.1.11.1.4 | Columndns340LUPSProduct | read-only | current | The product name of the UPS. |
| 1.3.6.1.4.1.171.50.1.10.1.1.11.1.5 | Columndns340LUPSBatteryCharge | read-only | current | The battery charge of the UPS. |
| 1.3.6.1.4.1.171.50.1.10.1.1.11.1.6 | Columndns340LUPSStatus | read-only | current | The status of this UPS. |
| 1.3.6.1.4.1.171.50.1.10.1.1.200 | NodenotifyEvts | |||
| 1.3.6.1.4.1.171.50.1.10.1.1.200.1 | NotificationnotifyPasswdChanged | current | An indication that the Administrator's password has been changed. | |
| 1.3.6.1.4.1.171.50.1.10.1.1.200.2 | NotificationnotifyFirmwareUpgraded | current | An indication that firmware has been upgraded. | |
| 1.3.6.1.4.1.171.50.1.10.1.1.200.3 | NotificationnotifyNetworkChanged | current | An indication that the network settings has been changed. | |
| 1.3.6.1.4.1.171.50.1.10.1.1.200.4 | NotificationnotifyTemperatureExceeded | current | An indication that system temperature has exceeded. |