MIB Viewer

DS8200v2-MIB

446 objects
DS8200v2 MIB.
OIDNameAccessStatusDescription
1.3.6.1.4.1.321.100.2IdentitytinterfacesDS8200v2 MIB.
1.3.6.1.4.1.321.100.2.1NodemgmtPorts
1.3.6.1.4.1.321.100.2.1.1TablemgmtPortsTablenot-accessiblecurrentThe Management Ports table.
1.3.6.1.4.1.321.100.2.1.1.1RowmgmtPortsTableEntrynot-accessiblecurrentAn entry in the Management Ports table.
1.3.6.1.4.1.321.100.2.1.1.1.1ColumnmgmtPortsTableIndexread-onlycurrentThe index into the Management Ports table.
1.3.6.1.4.1.321.100.2.1.1.1.2ColumnmgmtPortsDescriptionread-onlycurrentContains a textual description of the port.
1.3.6.1.4.1.321.100.2.1.1.1.3ColumnmgmtPortsElementIDread-writecurrentThis object signifies the name of the device.
1.3.6.1.4.1.321.100.2.1.1.1.4ColumnmgmtPortsModeread-writecurrentThis object signifies the method used by the port to report alarms.
1.3.6.1.4.1.321.100.2.1.1.1.5ColumnmgmtPortsDialPrefixread-writecurrentThis object contains the dial string prefix for a modem connected to the port.
1.3.6.1.4.1.321.100.2.1.1.1.6ColumnmgmtPortsPrimaryDialStringread-writecurrentThis object contains the primary dial string for a modem connected to the port.
1.3.6.1.4.1.321.100.2.1.1.1.7ColumnmgmtPortsSecondaryDialStringread-writecurrentThis object contains the secondary dial string for a modem connected to the port.
1.3.6.1.4.1.321.100.2.1.1.1.8ColumnmgmtPortsExtInitStringread-writecurrentThis object contains the init string for a modem connected to the port.
1.3.6.1.4.1.321.100.2.1.1.1.9ColumnmgmtPortsCompressedSlipread-writecurrentThis object specifies if SLIP compression is to be used.
1.3.6.1.4.1.321.100.2.1.1.1.10ColumnmgmtPortsInternalModemread-writecurrentThis object signifies if the internal modem (when present) is enabled.
1.3.6.1.4.1.321.100.2.2Nodedbu
1.3.6.1.4.1.321.100.2.2.1TabledbuConfigTablenot-accessiblecurrentThe Dial Backup Configuration Table.
1.3.6.1.4.1.321.100.2.2.1.1RowdbuConfigTableEntrynot-accessiblecurrentAn entry in the Dial Backup Configuration table.
1.3.6.1.4.1.321.100.2.2.1.1.1ColumndbuNearIndexread-onlycurrentSelects the near device.
1.3.6.1.4.1.321.100.2.2.1.1.2ColumndbuFarIndexread-onlycurrentSelects the far device.
1.3.6.1.4.1.321.100.2.2.1.1.3ColumndbuConfigTableIndexread-onlycurrentThe index into the Dial Backup table.
1.3.6.1.4.1.321.100.2.2.1.1.4ColumndbuDescriptionread-onlycurrentContains a textual description of the dbu.
1.3.6.1.4.1.321.100.2.2.1.1.5ColumndbuRateread-writecurrentThis object is the identifier of the current DDS DBU rate. The values mean: dbuRate2400 the DBU interface is operating at 2400bps dbuRate4800 the DBU interface…
1.3.6.1.4.1.321.100.2.2.1.1.6ColumndbuModeread-writecurrentThis object is the identifier of the current mode that the Dial Backup Unit is operating in. The values mean: dbuModeOrig The dial backup unit is operating in …
1.3.6.1.4.1.321.100.2.2.1.1.7ColumndbuFormatread-writecurrentThis object is the identifier of the current format that the Dial Backup Unit is operating in. The values mean: dbuFormatSync The dial backup unit is operating…
1.3.6.1.4.1.321.100.2.2.1.1.8ColumndbuNumberread-writecurrentThis string is the currently programmed number for the dial backup unit to call
1.3.6.1.4.1.321.100.2.2.1.1.9ColumndbuStatusread-onlycurrentThis object is the identifier of the current Dial Backup Unit operating status. The values mean: dbuStatusDisabled The dial backup unit is either not installed…
1.3.6.1.4.1.321.100.2.2.1.1.10ColumndbuCommandread-writecurrentThis object is the identifier of the current setting that the Dial Backup Unit is operating in. The values mean: dbuCommandDisable The dial backup unit is not …
1.3.6.1.4.1.321.100.2.2.1.1.11ColumndbuActivator1read-writecurrentThis object is the identifier of the current trigger that will activate the Dial Backup Unit. The values mean: dbuActivatorLOS The dial backup unit is activate…
1.3.6.1.4.1.321.100.2.2.1.1.12ColumndbuActivator2read-writecurrentThis object is the identifier of the current trigger that will activate the Dial Backup Unit. The values mean: dbuActivatorLOS The dial backup unit is activate…
1.3.6.1.4.1.321.100.2.2.1.1.13ColumndbuDialStrread-writecurrentThis string is the dial string sent to the dial backup unit during every connection attempt
1.3.6.1.4.1.321.100.2.2.1.1.14ColumndbuInitStrread-writecurrentThis string is the initialization string sent to the dial backup unit before every connection attempt
1.3.6.1.4.1.321.100.2.2.1.1.15ColumndbuHangupStrread-writecurrentThis string is the hangup command string sent to the dial backup unit after every successful call
1.3.6.1.4.1.321.100.2.2.1.1.16ColumndbuPasswordStrread-writecurrentThis string is the prompt character and password string for the dial backup unit in Callback DBU
1.3.6.1.4.1.321.100.2.2.1.1.17ColumndbuSecurityread-writecurrentEnables security on dial backup unit.
1.3.6.1.4.1.321.100.2.2.1.1.18ColumndbuDtrDialread-writecurrentEnables DTR dial feature on dial backup unit.
1.3.6.1.4.1.321.100.2.2.1.1.19ColumndbuISDNSwitchTyperead-writecurrentSpecifies the switch type for the ISDN DBU.
1.3.6.1.4.1.321.100.2.2.1.1.20ColumndbuISDNSwitchVersionread-writecurrentSpecifies the switch version for the ISDN DBU.
1.3.6.1.4.1.321.100.2.2.1.1.21ColumndbuISDNTEIread-writecurrentSpecifies the ISDN DBU TEI.
1.3.6.1.4.1.321.100.2.2.1.1.22ColumndbuISDNSPIDread-writecurrentSpecifies the SPID for the ISDN DBU.
1.3.6.1.4.1.321.100.2.2.1.1.23ColumndbuISDNDDNUMread-writecurrentSpecifies the Data Directory Number for the ISDN DBU.
1.3.6.1.4.1.321.100.2.2.2TabledbuResetStringsTablenot-accessiblecurrentA table of COLD START reprogramming strings for the dial backup unit.
1.3.6.1.4.1.321.100.2.2.2.1RowdbuResetStringsEntrynot-accessiblecurrentAn entry in the dbuResetStringsTable.
1.3.6.1.4.1.321.100.2.2.2.1.1ColumndbuResetNearIndexread-onlycurrentSelects the near device.
1.3.6.1.4.1.321.100.2.2.2.1.2ColumndbuResetFarIndexread-onlycurrentSelects the far device.
1.3.6.1.4.1.321.100.2.2.2.1.3ColumndbuResetConfigEntryIndexread-onlycurrentThe index into the Dial Backup table.
1.3.6.1.4.1.321.100.2.2.2.1.4ColumndbuResetStringsIndexread-onlycurrentThe index into the dbuResetStringsTable.
1.3.6.1.4.1.321.100.2.2.2.1.5ColumndbuResetStringread-writecurrentThis string is one of the dial backup unit's COLD START reprogramming strings
1.3.6.1.4.1.321.100.2.2.3TabledbuStartStopTablenot-accessiblecurrentThe Dial Backup StartStop Table.
1.3.6.1.4.1.321.100.2.2.3.1RowdbuStartStopTableEntrynot-accessiblecurrentAn entry in the Dial Backup Start Stop table.
1.3.6.1.4.1.321.100.2.2.3.1.1ColumndbuStartStopNearIndexread-onlycurrentSelects the near device.
1.3.6.1.4.1.321.100.2.2.3.1.2ColumndbuStartStopFarIndexread-onlycurrentSelects the far device.
1.3.6.1.4.1.321.100.2.2.3.1.3ColumndbuStartStopConfigEntryIndexread-onlycurrentThe index into the Dial Backup table.
1.3.6.1.4.1.321.100.2.2.3.1.4ColumndbuStartStopDayOfWeekread-onlycurrentThe index into the Dial Backup Start Stop times table.
1.3.6.1.4.1.321.100.2.2.3.1.5ColumndbuStartread-writecurrentThis object is the beginning of an allowable window for Dial Backup Activation.
1.3.6.1.4.1.321.100.2.2.3.1.6ColumndbuStopread-writecurrentThis object is the end of an allowable window for Dial Backup Activation.
1.3.6.1.4.1.321.100.2.3Nodet1e1
1.3.6.1.4.1.321.100.2.3.1Tablet1e1ConfigTablenot-accessiblecurrentThe T1 and E1 Configuration Table.
1.3.6.1.4.1.321.100.2.3.1.1Rowt1e1ConfigTableEntrynot-accessiblecurrentAn entry in the t1e1Table.
1.3.6.1.4.1.321.100.2.3.1.1.1Columnt1e1ConfigNearIndexread-onlycurrentSelects the near device.
1.3.6.1.4.1.321.100.2.3.1.1.2Columnt1e1ConfigFarIndexread-onlycurrentSelects the far device.
1.3.6.1.4.1.321.100.2.3.1.1.3Columnt1e1ConfigIndexread-onlycurrentThis object is the index into the t1e1Table.
1.3.6.1.4.1.321.100.2.3.1.1.4Columnt1e1Descriptionread-onlycurrentContains a textual description of the port.
1.3.6.1.4.1.321.100.2.3.1.1.5Columnt1e1Moderead-writecurrentThis object identifies the port as either a Network (long-haul) or DTE (short-haul) port.
1.3.6.1.4.1.321.100.2.3.1.1.6Columnt1e1FrameTyperead-writecurrentSelects the framing for the network side of the DSU/CSU.
1.3.6.1.4.1.321.100.2.3.1.1.7Columnt1e1LineCoderead-writecurrentSelects the network side line coding.
1.3.6.1.4.1.321.100.2.3.1.1.8Columnt1e1LineBuildOutread-writecurrentSelects the line build out for the network interface. The options are: t1e1LineBuildOut0db indicates a line build out of 0db t1e1LineBuildOut75db indicates a l…
1.3.6.1.4.1.321.100.2.3.1.1.9Columnt1e1Timingread-writecurrentSets the timing source to synchronize the unit's internal timing generators.
1.3.6.1.4.1.321.100.2.3.1.1.10Columnt1e1StationInTimingread-writecurrentSelects the input timing if t1e1Timing is set to Station.
1.3.6.1.4.1.321.100.2.3.1.1.11Columnt1e1StationTimingread-writecurrentSelects the N-multiple when Station Input Timing is set to either NX56 or NX65. The N range is 1..24
1.3.6.1.4.1.321.100.2.3.1.1.12Columnt1e1PRMread-writecurrentEnables the ANSI T1.403 Performance Report Message functions.
1.3.6.1.4.1.321.100.2.3.1.1.13Columnt1e1ZeroSuppressread-writecurrentDetermines whether ones density insertion is activated after 15 zeros . To ensure compliance with TR54016, this field must be enabled.
1.3.6.1.4.1.321.100.2.3.1.1.14Columnt1e1NationalBitread-writecurrentSelects a national bit to create a 4-kbps datalink between the endpoint units.
1.3.6.1.4.1.321.100.2.3.1.1.15Columnt1e1KeepAliveread-writecurrentSelects keep alive framed and unframed ones when the unit detects LOS or OOF.
1.3.6.1.4.1.321.100.2.3.1.1.16Columnt1e1CRC4Moderead-writecurrentSelects whether CRC4 is enabled or disabled.
1.3.6.1.4.1.321.100.2.3.1.1.17Columnt1e1DSXLevelread-writecurrentSelects the DSX1 interface output level.
1.3.6.1.4.1.321.100.2.3.1.1.18Columnt1e1CRCread-writecurrentDetermines whether received CRC data is passed through or regenerated.
1.3.6.1.4.1.321.100.2.3.1.1.19Columnt1e1FDLPassThroughread-writecurrentDetermines whether the ESF FDL passes through the CSU or terminates.
1.3.6.1.4.1.321.100.2.3.1.1.20Columnt1e1AudibleAlarmread-writecurrentIf applicable, Enables or Disables the CSU's internal buzzer which alerts users of an alarm condition.
1.3.6.1.4.1.321.100.2.3.1.1.21Columnt1e1Functionread-writecurrentSpecifies the function the network port will perform in the unit. The options are: t1e1FunctionNetwork (Independent network port) t1e1FunctionSlaved (Slaved to…
1.3.6.1.4.1.321.100.2.3.1.1.22Columnt1e1EBitGenerationread-writecurrent
1.3.6.1.4.1.321.100.2.3.1.1.23Columnt1e1RAIGenerationread-writecurrent
1.3.6.1.4.1.321.100.2.3.1.1.24Columnt1e1SpareBitInsertionread-writecurrent
1.3.6.1.4.1.321.100.2.3.1.1.25Columnt1e1Sa4Inread-onlycurrent
1.3.6.1.4.1.321.100.2.3.1.1.26Columnt1e1Sa5Inread-onlycurrent
1.3.6.1.4.1.321.100.2.3.1.1.27Columnt1e1Sa6Inread-onlycurrent
1.3.6.1.4.1.321.100.2.3.1.1.28Columnt1e1Sa7Inread-onlycurrent
1.3.6.1.4.1.321.100.2.3.1.1.29Columnt1e1Sa8Inread-onlycurrent
1.3.6.1.4.1.321.100.2.3.1.1.30Columnt1e1Sa4Outread-writecurrent
1.3.6.1.4.1.321.100.2.3.1.1.31Columnt1e1Sa5Outread-writecurrent
1.3.6.1.4.1.321.100.2.3.1.1.32Columnt1e1Sa6Outread-writecurrent
1.3.6.1.4.1.321.100.2.3.1.1.33Columnt1e1Sa7Outread-writecurrent
1.3.6.1.4.1.321.100.2.3.1.1.34Columnt1e1Sa8Outread-writecurrent
1.3.6.1.4.1.321.100.2.3.2Tablet1e1AlarmTablenot-accessiblecurrentThe T1 and E1 Alarm Table.
1.3.6.1.4.1.321.100.2.3.2.1Rowt1e1AlarmTableEntrynot-accessiblecurrentAn entry in the t1e1Table.
1.3.6.1.4.1.321.100.2.3.2.1.1Columnt1e1AlarmNearIndexread-onlycurrentSelects the near device.
1.3.6.1.4.1.321.100.2.3.2.1.2Columnt1e1AlarmFarIndexread-onlycurrentSelects the far device.
1.3.6.1.4.1.321.100.2.3.2.1.3Columnt1e1AlarmIndexread-onlycurrentThis object is the index into the t1e1Table.
1.3.6.1.4.1.321.100.2.3.2.1.4Columnt1e1StatusSummaryread-onlycurrentThis object provides a summary of the port status.
1.3.6.1.4.1.321.100.2.3.2.1.5Columnt1e1AlarmSummaryread-onlycurrentThis object provides a summary of the port alarms.
1.3.6.1.4.1.321.100.2.3.2.1.6Columnt1e1ESStatusread-onlycurrentReports if an Errored Second condition exists.
1.3.6.1.4.1.321.100.2.3.2.1.7Columnt1e1ESCountread-onlycurrentThis count contains the number of consecutive seconds an Errored Second condition has existed.
1.3.6.1.4.1.321.100.2.3.2.1.8Columnt1e1ESThresholdread-writecurrentSets the Errored Seconds alarm threshold. Setting this field to 0 disables the alarm. The threshold can be set to any value in the range 0 to 900.
1.3.6.1.4.1.321.100.2.3.2.1.9Columnt1e1ESAlarmread-onlycurrentThis status indicates if the Errors Seconds threshold is exceeded.
1.3.6.1.4.1.321.100.2.3.2.1.10Columnt1e1SESStatusread-onlycurrentReports if a Severely Errored condition exists.
1.3.6.1.4.1.321.100.2.3.2.1.11Columnt1e1SESCountread-onlycurrentThis count contains the number of consecutive seconds a Severely Errored condition has existed.
1.3.6.1.4.1.321.100.2.3.2.1.12Columnt1e1SESThresholdread-writecurrentSets the Severely Errored seconds alarm threshold. Setting this field to 0 disables the alarm. The threshold can be set to any value in the range 0 to 900.
1.3.6.1.4.1.321.100.2.3.2.1.13Columnt1e1SESAlarmread-onlycurrentThis status indicates if the Severely Errors Seconds threshold is exceeded.
1.3.6.1.4.1.321.100.2.3.2.1.14Columnt1e1LOSSStatusread-onlycurrentReports if a Loss of Signal condition exists.
1.3.6.1.4.1.321.100.2.3.2.1.15Columnt1e1LOSSCountread-onlycurrentThis count contains the number of consecutive seconds a Loss of Signal condition has existed.
1.3.6.1.4.1.321.100.2.3.2.1.16Columnt1e1LOSSThresholdread-writecurrentSets the Loss of Signal seconds alarm threshold. Setting this field to 0 disables the alarm. The threshold can be set to any value in the range 0 to 900.
1.3.6.1.4.1.321.100.2.3.2.1.17Columnt1e1LOSSAlarmread-onlycurrentThis status indicates if the Loss of Signal Seconds threshold is exceeded.
1.3.6.1.4.1.321.100.2.3.2.1.18Columnt1e1UASStatusread-onlycurrentReports if an Unavailable condition exists.
1.3.6.1.4.1.321.100.2.3.2.1.19Columnt1e1UASCountread-onlycurrentThis count contains the number of consecutive seconds an Unavailable condition has existed.
1.3.6.1.4.1.321.100.2.3.2.1.20Columnt1e1UASThresholdread-writecurrentSets the unavailable seconds alarm threshold. Setting this field to 0 disables the alarm. The threshold can be set to any value in the range 0 to 900.
1.3.6.1.4.1.321.100.2.3.2.1.21Columnt1e1UASAlarmread-onlycurrentThis status indicates if the Unavailable Seconds threshold is exceeded.
1.3.6.1.4.1.321.100.2.3.2.1.22Columnt1e1CSSStatusread-onlycurrentReports if a Controlled Slip condition exists.
1.3.6.1.4.1.321.100.2.3.2.1.23Columnt1e1CSSCountread-onlycurrentThis count contains the number of consecutive seconds in which at least one Controlled Slip occurred.
1.3.6.1.4.1.321.100.2.3.2.1.24Columnt1e1CSSThresholdread-writecurrentSets the Controlled Slip seconds alarm threshold. Setting this field to 0 disables the alarm. The threshold can be set to any value in the range 0 to 900.
1.3.6.1.4.1.321.100.2.3.2.1.25Columnt1e1CSSAlarmread-onlycurrentThis status indicates if the Controlled Slip seconds threshold is exceeded.
1.3.6.1.4.1.321.100.2.3.2.1.26Columnt1e1BPVSStatusread-onlycurrentReports if a Bipolar Violation Error condition exists.
1.3.6.1.4.1.321.100.2.3.2.1.27Columnt1e1BPVSCountread-onlycurrentThis count contains the number of consecutive seconds a Bipolar Violation Error condition has existed.
1.3.6.1.4.1.321.100.2.3.2.1.28Columnt1e1BPVSThresholdread-writecurrentSets the Bipolar Violation Error seconds alarm threshold. Setting this field to 0 disables the alarm. The threshold can be set to any value in the range 0 to 9…
1.3.6.1.4.1.321.100.2.3.2.1.29Columnt1e1BPVSAlarmread-onlycurrentThis status indicates if the Bipolar Violation Error seconds threshold is exceeded.
1.3.6.1.4.1.321.100.2.3.2.1.30Columnt1e1OOFSStatusread-onlycurrentIndicates that the unit is unable to synchronize on the incoming framing pattern.
1.3.6.1.4.1.321.100.2.3.2.1.31Columnt1e1OOFSCountread-onlycurrentThis count contains the number of consecutive seconds an OOF condition has existed.
1.3.6.1.4.1.321.100.2.3.2.1.32Columnt1e1OOFSThresholdread-writecurrentSets the OOF seconds alarm threshold. Setting this field to 0 disables the alarm. The threshold can be set to any value in the range 0 to 900.
1.3.6.1.4.1.321.100.2.3.2.1.33Columnt1e1OOFSAlarmread-onlycurrentIndicates if an OOF seconds alarm condition exists.
1.3.6.1.4.1.321.100.2.3.2.1.34Columnt1e1AISStatusread-onlycurrentIndicates that the unit is receiving an unframed all ones pattern.
1.3.6.1.4.1.321.100.2.3.2.1.35Columnt1e1AISCountread-onlycurrentThis count contains the number of consecutive seconds an Unframed All Ones condition has existed.
1.3.6.1.4.1.321.100.2.3.2.1.36Columnt1e1AISThresholdread-writecurrentSets the AIS seconds alarm threshold. Setting this field to 0 disables the alarm. The threshold can be set to any value in the range 0 to 900.
1.3.6.1.4.1.321.100.2.3.2.1.37Columnt1e1AISAlarmread-onlycurrentIndicates if an Unframed All Ones alarm condition exists.
1.3.6.1.4.1.321.100.2.3.2.1.38Columnt1e1RASStatusread-onlycurrentReports if a Remote (Yellow) Alarm condition exists.
1.3.6.1.4.1.321.100.2.3.2.1.39Columnt1e1RASCountread-onlycurrentThis count contains the number of consecutive seconds a Remote (Yellow) Alarm condition has existed.
1.3.6.1.4.1.321.100.2.3.2.1.40Columnt1e1RASThresholdread-writecurrentSets the RAS seconds alarm threshold. Setting this field to 0 disables the alarm. The threshold can be set to any value in the range 0 to 900.
1.3.6.1.4.1.321.100.2.3.2.1.41Columnt1e1RASAlarmread-onlycurrentThis status indicates if a Remote (Yellow) Alarm exists.
1.3.6.1.4.1.321.100.2.3.2.1.42Columnt1e1AlarmResetTimerread-writecurrentSets the Alarm Reset Timer, this field can be set to any value in the range 0 to 900.
1.3.6.1.4.1.321.100.2.3.2.1.43Columnt1e1AlarmResetread-writecurrentThis is used to clear the current alarm counts.
1.3.6.1.4.1.321.100.2.4NodeddsNet
1.3.6.1.4.1.321.100.2.4.1TableddsNetConfigTablenot-accessiblecurrentThe dds Network Interface Configuration Table.
1.3.6.1.4.1.321.100.2.4.1.1RowddsNetConfigTableEntrynot-accessiblecurrentAn entry in the Network Interface Table.
1.3.6.1.4.1.321.100.2.4.1.1.1ColumnddsNetConfigNearIndexread-onlycurrentSelects the near device.
1.3.6.1.4.1.321.100.2.4.1.1.2ColumnddsNetConfigFarIndexread-onlycurrentSelects the far device.
1.3.6.1.4.1.321.100.2.4.1.1.3ColumnddsNetConfigIndexread-onlycurrentIndex into the ddsNetConfigTable.
1.3.6.1.4.1.321.100.2.4.1.1.4ColumnddsNetDescriptionread-writecurrentContains a textual description of the port.
1.3.6.1.4.1.321.100.2.4.1.1.5ColumnddsNetRateread-writecurrentThis object is the identifier of the current DDS network rate. The values mean: ddsNetRate2400 the DDS network interface is operating at 2400bps ddsNetRate4800…
1.3.6.1.4.1.321.100.2.4.1.1.6ColumnddsNetModeread-writecurrentThis variable describes mode in which data is being sent from the DDS unit back towards the network. Changing the value of this variable can cause a loss of re…
1.3.6.1.4.1.321.100.2.4.1.1.7ColumnddsNetTimingSourceread-writecurrentThis variable describes the current timing source for the DDS network interface. The values mean: ddsNetTimingNet unit dependant upon network for DDS network i…
1.3.6.1.4.1.321.100.2.4.1.1.8ColumnddsNetRemCommread-onlycurrentThis variable describes the current setting for the remote communications link. The values mean: ddsNetRemCommEnabled remote communications can be carried out …
1.3.6.1.4.1.321.100.2.4.1.1.9ColumnddsNetCircuitAssurread-writecurrentThis variable describes the current setting for the circuit assurance option. The values mean: ddsNetCircuitAssurEnabled Circuit Assurance is enabled and the i…
1.3.6.1.4.1.321.100.2.4.1.1.10ColumnddsNetAntiStrTimerread-writecurrentThis variable describes the current setting for the anti streaming timer. The values mean: ddsNetAntiStrTimerOff the AntiStreaming Timer is off ddsNetAntiStrTi…
1.3.6.1.4.1.321.100.2.4.2TableddsNetAlarmTablenot-accessiblecurrentThe dds Network Interface Alarm Table.
1.3.6.1.4.1.321.100.2.4.2.1RowddsNetAlarmTableEntrynot-accessiblecurrentAn entry in the ddsNetAlarmTable.
1.3.6.1.4.1.321.100.2.4.2.1.1ColumnddsNetAlarmNearIndexread-onlycurrentSelects the near device.
1.3.6.1.4.1.321.100.2.4.2.1.2ColumnddsNetAlarmFarIndexread-onlycurrentSelects the far device.
1.3.6.1.4.1.321.100.2.4.2.1.3ColumnddsNetAlarmIndexread-onlycurrentIndex into the ddsNetAlarmTable.
1.3.6.1.4.1.321.100.2.4.2.1.4ColumnddsNetStatusSummaryread-onlycurrentThis object provides a summary of the port status.
1.3.6.1.4.1.321.100.2.4.2.1.5ColumnddsNetAlarmSummaryread-onlycurrentThis object provides a summary of the port alarms.
1.3.6.1.4.1.321.100.2.4.2.1.6ColumnddsNetLOSStatusread-onlycurrentReports if a Loss of Signal condition exists.
1.3.6.1.4.1.321.100.2.4.2.1.7ColumnddsNetLOSCountread-onlycurrentThis count contains the number of consecutive seconds the unit received signal has been interrupted.
1.3.6.1.4.1.321.100.2.4.2.1.8ColumnddsNetLOSThresholdread-writecurrentA period, measured in seconds, in which the DDS received signal is interrupted.
1.3.6.1.4.1.321.100.2.4.2.1.9ColumnddsNetLOSAlarmread-onlycurrentThis status indicates if the Loss of Signal Seconds threshold is exceeded.
1.3.6.1.4.1.321.100.2.4.2.1.10ColumnddsNetOOFStatusread-onlycurrentReports if an Out of Frame condition exists.
1.3.6.1.4.1.321.100.2.4.2.1.11ColumnddsNetOOFCountread-onlycurrentThis count contains the number of consecutive seconds the unit has received the out of frame code.
1.3.6.1.4.1.321.100.2.4.2.1.12ColumnddsNetOOFThresholdread-writecurrentA period, measured in seconds, in which the Out Of Frame code is received or a frame sync loss occurred.
1.3.6.1.4.1.321.100.2.4.2.1.13ColumnddsNetOOFAlarmread-onlycurrentThis status indicates if the Out of Frame Seconds threshold is exceeded.
1.3.6.1.4.1.321.100.2.4.2.1.14ColumnddsNetOOSStatusread-onlycurrentReports if Out of Service codes are received.
1.3.6.1.4.1.321.100.2.4.2.1.15ColumnddsNetOOSCountread-onlycurrentThis count contains the number of consecutive seconds the unit has received the out of service code.
1.3.6.1.4.1.321.100.2.4.2.1.16ColumnddsNetOOSThresholdread-writecurrentA period, measured in seconds, in which the Out Of Service code is received.
1.3.6.1.4.1.321.100.2.4.2.1.17ColumnddsNetOOSAlarmread-onlycurrentThis status indicates if the Out of Service Seconds threshold is exceeded.
1.3.6.1.4.1.321.100.2.4.2.1.18ColumnddsNetFDLStatusread-onlycurrentReports if Facility Data Link errors have occurred.
1.3.6.1.4.1.321.100.2.4.2.1.19ColumnddsNetFDLCountread-onlycurrentThis count contains the number of consecutive seconds in which FDL errors have occurred.
1.3.6.1.4.1.321.100.2.4.2.1.20ColumnddsNetFDLThresholdread-writecurrentA period, measured in seconds, in which FDL errors have occurred.
1.3.6.1.4.1.321.100.2.4.2.1.21ColumnddsNetFDLAlarmread-onlycurrentThis status indicates if the Facility Data Link threshold is exceeded.
1.3.6.1.4.1.321.100.2.4.2.1.22ColumnddsNetAlarmResetTimerread-writecurrentSets the Alarm Reset Timer, this field can be set to any value in the range 0 to 900.
1.3.6.1.4.1.321.100.2.4.2.1.23ColumnddsNetAlarmResetread-writecurrentThis is used to clear the current alarm counts.
1.3.6.1.4.1.321.100.2.4.2.1.24ColumnddsNetBPVStatusread-onlycurrentReports if a Bipolar violation event occurred in the last second.
1.3.6.1.4.1.321.100.2.4.2.1.25ColumnddsNetBPVCountread-onlycurrentThis count contains the number of consecutive seconds the unit received bipolar violations.
1.3.6.1.4.1.321.100.2.4.2.1.26ColumnddsNetBPVThresholdread-writecurrentA period, measured in seconds, in which the unit receives bipolar violations before an alarm is triggered.
1.3.6.1.4.1.321.100.2.4.2.1.27ColumnddsNetBPVAlarmread-onlycurrentThis status indicates if the Bipolar violation Seconds threshold is exceeded.
1.3.6.1.4.1.321.100.2.5NodeserialDte
1.3.6.1.4.1.321.100.2.5.1TableserialDteConfigTablenot-accessiblecurrentThe Serial DTE Config Table.
1.3.6.1.4.1.321.100.2.5.1.1RowserialDteConfigTableEntrynot-accessiblecurrentAn entry in the serial DTE Config Table.
1.3.6.1.4.1.321.100.2.5.1.1.1ColumnserialDteConfigNearIndexread-onlycurrentSelects the near device.
1.3.6.1.4.1.321.100.2.5.1.1.2ColumnserialDteConfigFarIndexread-onlycurrentSelects the far device.
1.3.6.1.4.1.321.100.2.5.1.1.3ColumnserialDteConfigIndexread-onlycurrentIndex into the DteTable.
1.3.6.1.4.1.321.100.2.5.1.1.4ColumnserialDteDescriptionread-onlycurrentContains a textual description of the port.
1.3.6.1.4.1.321.100.2.5.1.1.5ColumnserialDteTyperead-writecurrentSelects the DTE port type if applicable.
1.3.6.1.4.1.321.100.2.5.1.1.6ColumnserialDteRateread-writecurrentSelects the DTE port bit.
1.3.6.1.4.1.321.100.2.5.1.1.7ColumnserialDteInvertDataread-writecurrentSpecifies whether transmit and receive are inverted at the port.
1.3.6.1.4.1.321.100.2.5.1.1.8ColumnserialDteFormatread-writecurrentThis variable describes the current operations format of the DTE interface. The values mean: serialDteFormatSync The DTE interface is currently set to operate …
1.3.6.1.4.1.321.100.2.5.1.1.9ColumnserialDteParityread-writecurrentThis variable describes the current parity selected for the DTE interface. This variable is only valid when the DTE Mode is set to ASYNC. The values mean: seri…
1.3.6.1.4.1.321.100.2.5.1.1.10ColumnserialDteStopBitread-writecurrentThis variable describes the stop bit setting for the DTE interface. This variable is only valid when the DTE interface is set to ASYNC. The values mean: serial…
1.3.6.1.4.1.321.100.2.5.1.1.11ColumnserialDteModeread-writecurrentThis variable describes mode in which data is being sent from the DDS unit back towards the network.
1.3.6.1.4.1.321.100.2.5.1.1.12ColumnserialDteDSRread-writecurrentSelects DSR behavior.
1.3.6.1.4.1.321.100.2.5.1.1.13ColumnserialDteDCDread-writecurrentSelects DCD behavior.
1.3.6.1.4.1.321.100.2.5.1.1.14ColumnserialDteRTSread-writecurrentSelects RTS behavior.
1.3.6.1.4.1.321.100.2.5.1.1.15ColumnserialDteRTSDelayread-writecurrentSelects RTS to CTS transition delay.
1.3.6.1.4.1.321.100.2.5.1.1.16ColumnserialDteDTRread-onlycurrentReports if DTR from the DTE device is false.
1.3.6.1.4.1.321.100.2.5.1.1.17ColumnserialDteCTSread-writecurrentSpecifies the control of the CTS signal at the port.
1.3.6.1.4.1.321.100.2.5.1.1.18ColumnserialDteV54read-writecurrentSpecifies if the unit should respond to inband V.54 loop commands.
1.3.6.1.4.1.321.100.2.5.1.1.19ColumnserialDteLLread-writecurrentSpecifies if the unit should respond to local loop activation by the local loopback signal (EIA530 or RS-232 pin 18).
1.3.6.1.4.1.321.100.2.5.1.1.20ColumnserialDteRLread-writecurrentSpecifies if the unit should respond to remote loop activation by the remote loopback signal (EIA530 or RS-232 pin 21).
1.3.6.1.4.1.321.100.2.5.1.1.21ColumnserialDteStartChannelread-writecurrentSpecifies the starting channel for the interface.
1.3.6.1.4.1.321.100.2.5.1.1.22ColumnserialDteNumberOfChannelsread-writecurrentSpecifies the number of channels allocated to the interface.
1.3.6.1.4.1.321.100.2.5.1.1.23ColumnserialDteTxClockread-writecurrentSpecifies how the interface derives its transmit clock.
1.3.6.1.4.1.321.100.2.5.1.1.24ColumnserialDteBundleread-writecurrentSpecifies the allocation pattern of channels assigned to the serial port.
1.3.6.1.4.1.321.100.2.5.1.1.25ColumnserialDteChannelRateread-writecurrentSpecifies the rate of all channels assigned to the serial port.
1.3.6.1.4.1.321.100.2.5.1.1.26ColumnserialDteInvertClockread-writecurrentSpecifies if an inverted clock is used to send data from the serial port.
1.3.6.1.4.1.321.100.2.5.1.1.27ColumnserialDteCharSizeread-writecurrentSpecifies the number of bits per character. This variable is valid in ASYNC mode.
1.3.6.1.4.1.321.100.2.5.1.1.28ColumnserialDteFlowControlread-writecurrentSpecifies the Flow control to use. This variable is valid only in ASYNC mode.
1.3.6.1.4.1.321.100.2.5.1.1.29ColumnserialDtePinStatusread-onlycurrentThis object provides a summary of the Serial port pin status.
1.3.6.1.4.1.321.100.2.5.1.1.30ColumnserialDteInInvertClockread-writecurrentSpecifies to use the inverted clock edge for data clocked into the serial port.
1.3.6.1.4.1.321.100.2.5.2TableserialDteAlarmTablenot-accessiblecurrentThe Serial DTE Alarm Table.
1.3.6.1.4.1.321.100.2.5.2.1RowserialDteAlarmTableEntrynot-accessiblecurrentAn entry in the serial DTE Alarm Table.
1.3.6.1.4.1.321.100.2.5.2.1.1ColumnserialDteAlarmNearIndexread-onlycurrentSelects the near device.
1.3.6.1.4.1.321.100.2.5.2.1.2ColumnserialDteAlarmFarIndexread-onlycurrentSelects the far device.
1.3.6.1.4.1.321.100.2.5.2.1.3ColumnserialDteAlarmIndexread-onlycurrentIndex into the serialDteAlarmTable.
1.3.6.1.4.1.321.100.2.5.2.1.4ColumnserialDteDTRAlarmControlread-writecurrentSpecifies if the unit should alarm on loss of DTR.
1.3.6.1.4.1.321.100.2.5.2.1.5ColumnserialDteDTRAlarmStatusread-onlycurrentThis status indicates a DTR Loss alarm is active.
1.3.6.1.4.1.321.100.2.5.2.1.6ColumnserialDteStatusSummaryread-onlycurrentThis object provides a summary of the port status.
1.3.6.1.4.1.321.100.2.5.2.1.7ColumnserialDteAlarmSummaryread-onlycurrentThis object provides a summary of the port alarms.
1.3.6.1.4.1.321.100.2.5.2.1.8ColumnserialDteASCStatusread-onlycurrentReports if an ASC condition exists on the interface.
1.3.6.1.4.1.321.100.2.5.2.1.9ColumnserialDteASCCountread-onlycurrentThis count contains the number of ASC seconds received by the interface.
1.3.6.1.4.1.321.100.2.5.2.1.10ColumnserialDteASCThresholdread-writecurrentThe number of ASC seconds that must be received before an alarm is declared.
1.3.6.1.4.1.321.100.2.5.2.1.11ColumnserialDteASCAlarmread-onlycurrentThis status indicates if the ASC Seconds threshold is exceeded.
1.3.6.1.4.1.321.100.2.5.2.1.12ColumnserialDteFDLStatusread-onlycurrentReports if an FDL error condition exists on the interface.
1.3.6.1.4.1.321.100.2.5.2.1.13ColumnserialDteFDLCountread-onlycurrentThis count contains the number of FDL errored seconds received by the interface.
1.3.6.1.4.1.321.100.2.5.2.1.14ColumnserialDteFDLThresholdread-writecurrentThe number of FDL errored seconds that must be received before an alarm is declared.
1.3.6.1.4.1.321.100.2.5.2.1.15ColumnserialDteFDLAlarmread-onlycurrentThis status indicates if the FDL Errored Seconds threshold is exceeded.
1.3.6.1.4.1.321.100.2.5.2.1.16ColumnserialDteLOSStatusread-onlycurrentReports if an LOS condition exists on the interface.
1.3.6.1.4.1.321.100.2.5.2.1.17ColumnserialDteLOSCountread-onlycurrentThis count contains the number of LOS seconds received by the interface.
1.3.6.1.4.1.321.100.2.5.2.1.18ColumnserialDteLOSThresholdread-writecurrentThe number of LOS seconds that must be received before an alarm is declared.
1.3.6.1.4.1.321.100.2.5.2.1.19ColumnserialDteLOSAlarmread-onlycurrentThis status indicates if the LOS Seconds threshold is exceeded.
1.3.6.1.4.1.321.100.2.6NodeanalogDte
1.3.6.1.4.1.321.100.2.6.1TableanalogDteTablenot-accessiblecurrentThe Analog DTE Table.
1.3.6.1.4.1.321.100.2.6.1.1RowanalogDteTableEntrynot-accessiblecurrentAn entry in the Analog DTE Table.
1.3.6.1.4.1.321.100.2.6.1.1.1ColumnanalogDteNearIndexread-onlycurrentSelects the near device.
1.3.6.1.4.1.321.100.2.6.1.1.2ColumnanalogDteFarIndexread-onlycurrentSelects the far device.
1.3.6.1.4.1.321.100.2.6.1.1.3ColumnanalogDteIndexread-onlycurrentIndex into the analogDteTable.
1.3.6.1.4.1.321.100.2.6.1.1.4ColumnanalogDteDescriptionread-onlycurrentContains a textual description of the port.
1.3.6.1.4.1.321.100.2.6.1.1.5ColumnanalogDteCardTyperead-onlycurrentIdentifies the analog DTE card type.
1.3.6.1.4.1.321.100.2.6.1.1.6ColumnanalogDteModeread-writecurrentSelects whether the port is actively assigned to a network channel or not used.
1.3.6.1.4.1.321.100.2.6.1.1.7ColumnanalogDteStateread-onlycurrentDisplays the port status as either in the Busy or Idle state.
1.3.6.1.4.1.321.100.2.6.1.1.8ColumnanalogDteElementIDread-writecurrentThis object signifies the name of the device.
1.3.6.1.4.1.321.100.2.6.1.1.9ColumnanalogDteSignallingread-writecurrentSelects the supervisory operation of the port.
1.3.6.1.4.1.321.100.2.6.1.1.10ColumnanalogDteDNISDelayread-writecurrentIf the signalling mode has a delay, it can be set from 1 to 5 seconds.
1.3.6.1.4.1.321.100.2.6.1.1.11ColumnanalogDteTxGainread-writecurrentSelects the transmit gain. Values prefixed with m are negative.
1.3.6.1.4.1.321.100.2.6.1.1.12ColumnanalogDteRxGainread-writecurrentSelects the receive gain. Values prefixed with m are negative.
1.3.6.1.4.1.321.100.2.7Nodeconnection
1.3.6.1.4.1.321.100.2.7.1TableconnectionTablenot-accessiblecurrentThe connection table.
1.3.6.1.4.1.321.100.2.7.1.1RowconnectionTableEntrynot-accessiblecurrentAn entry in the connection table.
1.3.6.1.4.1.321.100.2.7.1.1.1ColumnconnectionNearIndexread-onlycurrentSelects the near device.
1.3.6.1.4.1.321.100.2.7.1.1.2ColumnconnectionFarIndexread-onlycurrentSelects the far device.
1.3.6.1.4.1.321.100.2.7.1.1.3ColumnconnectionTableIndexread-onlycurrentThe index into the connection table.
1.3.6.1.4.1.321.100.2.7.1.1.4ColumnconnectionTableDescriptionread-onlycurrentA description of the connection.
1.3.6.1.4.1.321.100.2.7.2TableconnectionChannelTablenot-accessiblecurrentThe channel-level connection table.
1.3.6.1.4.1.321.100.2.7.2.1RowconnectionChannelEntrynot-accessiblecurrentAn entry in the connectionChannelTable.
1.3.6.1.4.1.321.100.2.7.2.1.1ColumnconnectionChannelNearIndexread-onlycurrentSelects the near device.
1.3.6.1.4.1.321.100.2.7.2.1.2ColumnconnectionChannelFarIndexread-onlycurrentSelects the far device.
1.3.6.1.4.1.321.100.2.7.2.1.3ColumnconnectionChannelLineIndexread-onlycurrentSelects instance of line.
1.3.6.1.4.1.321.100.2.7.2.1.4ColumnconnectionChannelIndexread-onlycurrentThe index into the connection table.
1.3.6.1.4.1.321.100.2.7.2.1.5ColumnchannelInterfaceAssignmentread-writecurrentThe channel assignment.
1.3.6.1.4.1.321.100.2.7.2.1.6ColumnchannelInterfaceDescriptionread-onlycurrentContains a description of the interface channel connection.
1.3.6.1.4.1.321.100.2.7.2.1.7ColumnchannelInterfaceChannelread-writecurrentDisplays the corresponding channel of the interface channel connection.
1.3.6.1.4.1.321.100.2.7.2.1.8ColumnchannelSignallingread-writecurrentAllows a selection of Clear Channel or Robbed Bit signalling for each DS0.
1.3.6.1.4.1.321.100.2.8Nodemaintenance
1.3.6.1.4.1.321.100.2.8.1TablebertTablenot-accessiblecurrentBERT control table.
1.3.6.1.4.1.321.100.2.8.1.1RowbertTableEntrynot-accessiblecurrentAn entry in the BERT control table.
1.3.6.1.4.1.321.100.2.8.1.1.1ColumnbertNearIndexread-onlycurrentSelects the near device.
1.3.6.1.4.1.321.100.2.8.1.1.2ColumnbertFarIndexread-onlycurrentSelects the far device.
1.3.6.1.4.1.321.100.2.8.1.1.3ColumnbertIndexread-onlycurrentThe index into the BERT control table. Selects which BERT chip to use.
1.3.6.1.4.1.321.100.2.8.1.1.4ColumnbertPatternread-writecurrentSelects the test pattern to be used.
1.3.6.1.4.1.321.100.2.8.1.1.5ColumnbertLengthread-writecurrentSpecifies how long the test should run.
1.3.6.1.4.1.321.100.2.8.1.1.6ColumnbertPatternSyncread-onlycurrentDisplays the current state of pattern sync during a test.
1.3.6.1.4.1.321.100.2.8.1.1.7ColumnbertElapsedTimeread-onlycurrentDisplays the amount of time elapsed since a timed test began in seconds.
1.3.6.1.4.1.321.100.2.8.1.1.8ColumnbertBitErrorsread-onlycurrentDisplays the total number of bit errors detected since the test began.
1.3.6.1.4.1.321.100.2.8.1.1.9ColumnbertErroredSecondsread-onlycurrentDisplays the number of asynchronous errored seconds that have been detected since the test began.
1.3.6.1.4.1.321.100.2.8.1.1.10ColumnbertPercentEFSread-onlycurrentDisplays a ratio derived from the number of error free seconds divided by the number of seconds accumulated in elapsed time.
1.3.6.1.4.1.321.100.2.8.1.1.11ColumnbertCommandread-writecurrentIssues a test command for the interface.
1.3.6.1.4.1.321.100.2.8.2TablebertInterfaceTablenot-accessiblecurrentBERT control interface table.
1.3.6.1.4.1.321.100.2.8.2.1RowbertInterfaceTableEntrynot-accessiblecurrentAn entry in the BERT control interface table.
1.3.6.1.4.1.321.100.2.8.2.1.1ColumnbertInterfaceNearIndexread-onlycurrentSelects the near device.
1.3.6.1.4.1.321.100.2.8.2.1.2ColumnbertInterfaceFarIndexread-onlycurrentSelects the far device.
1.3.6.1.4.1.321.100.2.8.2.1.3ColumnbertChipIndexread-onlycurrentSelects which BERT chip to use.
1.3.6.1.4.1.321.100.2.8.2.1.4ColumnbertInterfaceIndexread-onlycurrentAn index into the MIB-II interfaces table; the interface for the BERT settings.
1.3.6.1.4.1.321.100.2.8.2.1.5ColumnbertInterfaceSettingread-writecurrentSpecifies where to send the BERT pattern.
1.3.6.1.4.1.321.100.2.8.2.1.6ColumnbertInterfaceServiceread-writecurrentSpecifies the service (see ipadv2.mib) to BERT. The bandwidth associated with the service will get the BERT pattern.
1.3.6.1.4.1.321.100.2.8.2.1.7ColumnbertInterfaceChannelRateread-writecurrentSpecifies the network channel rate for all channels involved in a network BERT.
1.3.6.1.4.1.321.100.2.8.3TabletestTablenot-accessiblecurrentTest control table.
1.3.6.1.4.1.321.100.2.8.3.1RowtestTableEntrynot-accessiblecurrentAn entry in the testTable.
1.3.6.1.4.1.321.100.2.8.3.1.1ColumntestNearIndexread-onlycurrentSelects the near device.
1.3.6.1.4.1.321.100.2.8.3.1.2ColumntestFarIndexread-onlycurrentSelects the far device.
1.3.6.1.4.1.321.100.2.8.3.1.3ColumntestTableIndexread-onlycurrentThe index into the testTable, one entry for each interface.
1.3.6.1.4.1.321.100.2.8.3.1.4ColumntestTyperead-writecurrentIdentifies the test type for the interface.
1.3.6.1.4.1.321.100.2.8.3.1.5ColumntestLoopDirectionread-writecurrentThis object is the identifier of the current unit loop mode. The values mean: testLoopUnidirectional Line, Data, and V54 loops will be unidirectional Local loo…
1.3.6.1.4.1.321.100.2.8.3.1.6ColumntestFarLLBFramingread-writecurrentThis setting, for Far LLB tests on T1 lines, must match the far end unit loop code framing.
1.3.6.1.4.1.321.100.2.8.3.1.7ColumntestLoopInitiatorread-onlycurrentIndicates who started the loop.
1.3.6.1.4.1.321.100.2.8.3.1.8ColumntestDefaultLoopTyperead-writecurrentIdentifies the default loop type.
1.3.6.1.4.1.321.100.2.9Nodeperformance
1.3.6.1.4.1.321.100.2.9.1Tableperformance24Tablenot-accessiblecurrentPerformance table, contains TR54016 standard and enhanced data.
1.3.6.1.4.1.321.100.2.9.1.1Rowperformance24TableEntrynot-accessiblecurrentAn entry in the performance24Table.
1.3.6.1.4.1.321.100.2.9.1.1.1Columnperformance24NearIndexread-onlycurrentSelects the near device.
1.3.6.1.4.1.321.100.2.9.1.1.2Columnperformance24FarIndexread-onlycurrentSelects the far device.
1.3.6.1.4.1.321.100.2.9.1.1.3Columnperformance24InterfaceIndexread-onlycurrentSelects the interface.
1.3.6.1.4.1.321.100.2.9.1.1.4Columnperformance24Indexread-onlycurrentThe index into the 24-hour performance table.
1.3.6.1.4.1.321.100.2.9.1.1.5Columnperformance24ESread-onlycurrentThe number of Errored Seconds for the 15-minute period.
1.3.6.1.4.1.321.100.2.9.1.1.6Columnperformance24BESread-onlycurrentThe number of Bursty Errored Seconds for the 15-minute period.
1.3.6.1.4.1.321.100.2.9.1.1.7Columnperformance24SESread-onlycurrentThe number of Severely Errored Seconds for the 15-minute period.
1.3.6.1.4.1.321.100.2.9.1.1.8Columnperformance24UASread-onlycurrentThe number of Unavailable Seconds for the 15-minute period.
1.3.6.1.4.1.321.100.2.9.1.1.9Columnperformance24LOFCread-onlycurrentThe number of Loss of Frame Counts for the 15-minute period.
1.3.6.1.4.1.321.100.2.9.1.1.10Columnperformance24CSSread-onlycurrentThe number of Controlled Slip Seconds for the 15-minute period.
1.3.6.1.4.1.321.100.2.9.1.1.11Columnperformance24CRCESread-onlycurrentThe number of CRC Errored Seconds for the 15-minute period.
1.3.6.1.4.1.321.100.2.9.1.1.12Columnperformance24OOFSread-onlycurrentThe number of Out of Frame Seconds for the 15-minute period.
1.3.6.1.4.1.321.100.2.9.1.1.13Columnperformance24LOSSread-onlycurrentThe number of Loss of Signal Seconds for the 15-minute period.
1.3.6.1.4.1.321.100.2.9.1.1.14Columnperformance24AISSread-onlycurrentThe number of Alarm Indication Signal Seconds for the 15-minute period.
1.3.6.1.4.1.321.100.2.9.1.1.15Columnperformance24RASread-onlycurrentThe number of Remote Alarm (Yellow) Seconds for the 15-minute period.
1.3.6.1.4.1.321.100.2.9.1.1.16Columnperformance24BPVSread-onlycurrentThe number of Bipolar Violation Seconds for the 15-minute period.
1.3.6.1.4.1.321.100.2.9.1.1.17Columnperformance24timestampread-onlycurrentThe value of sysUpTime when the statistics were last updated.
1.3.6.1.4.1.321.100.2.9.2Tableperformance30Tablenot-accessiblecurrentPerformance table, contains TR54016 standard and enhanced 30-day data.
1.3.6.1.4.1.321.100.2.9.2.1Rowperformance30TableEntrynot-accessiblecurrentAn entry in the performance30Table.
1.3.6.1.4.1.321.100.2.9.2.1.1Columnperformance30NearIndexread-onlycurrentSelects the near device.
1.3.6.1.4.1.321.100.2.9.2.1.2Columnperformance30FarIndexread-onlycurrentSelects the far device.
1.3.6.1.4.1.321.100.2.9.2.1.3Columnperformance30InterfaceIndexread-onlycurrentSelects the interface.
1.3.6.1.4.1.321.100.2.9.2.1.4Columnperformance30Indexread-onlycurrentThe index into the 30-day performance table.
1.3.6.1.4.1.321.100.2.9.2.1.5Columnperformance30ESread-onlycurrentThe number of Errored Seconds for the 1-day period.
1.3.6.1.4.1.321.100.2.9.2.1.6Columnperformance30BESread-onlycurrentThe number of Bursty Errored Seconds for the 1-day period.
1.3.6.1.4.1.321.100.2.9.2.1.7Columnperformance30SESread-onlycurrentThe number of Severely Errored Seconds for the 1-day period.
1.3.6.1.4.1.321.100.2.9.2.1.8Columnperformance30UASread-onlycurrentThe number of Unavailable Seconds for the 1-day period.
1.3.6.1.4.1.321.100.2.9.2.1.9Columnperformance30LOFCread-onlycurrentThe number of Loss of Frame Counts for the 1-day period.
1.3.6.1.4.1.321.100.2.9.2.1.10Columnperformance30CSSread-onlycurrentThe number of Controlled Slip Seconds for the 1-day period.
1.3.6.1.4.1.321.100.2.9.2.1.11Columnperformance30CRCESread-onlycurrentThe number of CRC Errored Seconds for the 1-day period.
1.3.6.1.4.1.321.100.2.9.2.1.12Columnperformance30OOFSread-onlycurrentThe number of Out of Frame Seconds for the 1-day period.
1.3.6.1.4.1.321.100.2.9.2.1.13Columnperformance30LOSSread-onlycurrentThe number of Loss of Signal Seconds for the 1-day period.
1.3.6.1.4.1.321.100.2.9.2.1.14Columnperformance30AISSread-onlycurrentThe number of Alarm Indication Signal Seconds for the 1-day period.
1.3.6.1.4.1.321.100.2.9.2.1.15Columnperformance30RASread-onlycurrentThe number of Remote Alarm (Yellow) Seconds for the 1-day period.
1.3.6.1.4.1.321.100.2.9.2.1.16Columnperformance30BPVSread-onlycurrentThe number of Bipolar Violation Seconds for the 1-day period.
1.3.6.1.4.1.321.100.2.9.2.1.17Columnperformance30timestampread-onlycurrentThe value of sysUpTime when the statistics were last updated.
1.3.6.1.4.1.321.100.2.10Nodeitable
1.3.6.1.4.1.321.100.2.10.1TableiTablenot-accessiblecurrentThe interface table.
1.3.6.1.4.1.321.100.2.10.1.1RowiTableEntrynot-accessiblecurrentAn entry in the interface table.
1.3.6.1.4.1.321.100.2.10.1.1.1ColumniTableNearIndexread-onlycurrentSelects the near device.
1.3.6.1.4.1.321.100.2.10.1.1.2ColumniTableFarIndexread-onlycurrentSelects the far device.
1.3.6.1.4.1.321.100.2.10.1.1.3ColumniTableIndexread-onlycurrentThe index into the interface table, used for addressing in above tables.
1.3.6.1.4.1.321.100.2.10.1.1.4ColumniDescriptionread-onlycurrentDescription of the interface.
1.3.6.1.4.1.321.100.2.10.1.1.5ColumniTyperead-onlycurrentEnumerated interface type.
1.3.6.1.4.1.321.100.2.10.1.1.6ColumniSlotread-onlycurrentDevice-dependent slot in which the interface resides.
1.3.6.1.4.1.321.100.2.10.1.1.7ColumniPortread-onlycurrentDevice-dependent port in which the interface resides.
1.3.6.1.4.1.321.100.2.10.1.1.8ColumniStatusread-onlycurrentStatus of the interface.
1.3.6.1.4.1.321.100.2.11Nodetraplog
1.3.6.1.4.1.321.100.2.11.1TabletraplogTablenot-accessiblecurrentThe traplog table.
1.3.6.1.4.1.321.100.2.11.1.1RowtraplogEntrynot-accessiblecurrentAn entry in the traplog table.
1.3.6.1.4.1.321.100.2.11.1.1.1ColumntraplogIndexread-onlycurrentThe index into the traplog table.
1.3.6.1.4.1.321.100.2.11.1.1.2ColumntraplogNearIndexread-onlycurrentSpecifies the near device.
1.3.6.1.4.1.321.100.2.11.1.1.3ColumntraplogFarIndexread-onlycurrentSpecifies the far device.
1.3.6.1.4.1.321.100.2.11.1.1.4ColumntraplogInterfaceIndexread-onlycurrentSpecifies the interface.
1.3.6.1.4.1.321.100.2.11.1.1.5ColumntraplogTrapNumread-onlycurrentThe SNMP trap id.
1.3.6.1.4.1.321.100.2.11.1.1.6ColumntraplogTimeStampread-onlycurrentTime the SNMP was generated.
1.3.6.1.4.1.321.100.2.11.1.1.7ColumntraplogDeviceTyperead-onlycurrentSpecifies the device type for the trap.
1.3.6.1.4.1.321.100.2.11.1.1.8ColumntraplogOID1read-onlycurrentSNMP Object ID of 1st varbind.
1.3.6.1.4.1.321.100.2.11.1.1.9ColumntraplogDescription1read-onlycurrentDescription of 1st varbind.
1.3.6.1.4.1.321.100.2.11.1.1.10ColumntraplogValue1read-onlycurrentValue of of 1st varbind.
1.3.6.1.4.1.321.100.2.11.1.1.11ColumntraplogOID2read-onlycurrentSNMP Object ID of 2nd varbind.
1.3.6.1.4.1.321.100.2.11.1.1.12ColumntraplogDescription2read-onlycurrentDescription of 2nd varbind.
1.3.6.1.4.1.321.100.2.11.1.1.13ColumntraplogValue2read-onlycurrentValue of of 2nd varbind.
1.3.6.1.4.1.321.100.2.11.1.1.14ColumntraplogOID3read-onlycurrentSNMP Object ID of 3rd varbind.
1.3.6.1.4.1.321.100.2.11.1.1.15ColumntraplogDescription3read-onlycurrentDescription of 3rd varbind.
1.3.6.1.4.1.321.100.2.11.1.1.16ColumntraplogValue3read-onlycurrentValue of of 3rd varbind.
1.3.6.1.4.1.321.100.2.11.2ScalartraplogDeleteEntryread-writecurrentWriting the index of a trap to this object will delete the trap entry. Writing an index value of 0 will delete all entries.
1.3.6.1.4.1.321.100.2.11.3ScalartraplogSortOptionread-writecurrentDetermines the order in which traps are presented.
1.3.6.1.4.1.321.100.2.11.4ScalartraplogLastTimeStampread-onlycurrentThe timestamp of the newest trap in the trap log.
1.3.6.1.4.1.321.100.2.12NodeunitUtilities
1.3.6.1.4.1.321.100.2.12.1TableunitUtilitiesTablenot-accessiblecurrentThe unit utilities table.
1.3.6.1.4.1.321.100.2.12.1.1RowunitUtilitiesTableEntrynot-accessiblecurrentAn entry in the unit utilities table.
1.3.6.1.4.1.321.100.2.12.1.1.1ColumnunitUtilitiesNearIndexread-onlycurrentSelects the near device.
1.3.6.1.4.1.321.100.2.12.1.1.2ColumnunitUtilitiesFarIndexread-onlycurrentSelects the far device.
1.3.6.1.4.1.321.100.2.12.1.1.3ColumnunitUtilitiesLocalPasswordread-writecurrentThe password for local access to a device (VT100, front panel).
1.3.6.1.4.1.321.100.2.12.1.1.4ColumnunitUtilitiesTimeread-writecurrentThis string is the current time as known to the device. The current time may be entered in this field using the HHMMSS format. For example, 3:45AM is entered a…
1.3.6.1.4.1.321.100.2.12.1.1.5ColumnunitUtilitiesDateread-writecurrentThis string is the current date as known to the device. The current date may be entered in this field using the MMDDYY format. For example, July 4, 1997 is ent…
1.3.6.1.4.1.321.100.2.12.1.1.6ColumnunitUtilitiesMaintenanceResetread-writecurrentThis field allows resetting the device to default values by reloading the start-up default configuration parameters.
1.3.6.1.4.1.321.100.2.12.1.1.7ColumnunitUtilitiesAlarmResetTimerread-writecurrentThis field allows setting a timer which will cause all existing alarms on the device to be cleared upon expiration. The counter is in seconds.
1.3.6.1.4.1.321.100.2.12.1.1.8ColumnunitUtilitiesAlarmClearread-writecurrentWriting a value of utilitiesAlarmClearNow(2) to this field causes all existing alarms to be cleared immediately.
1.3.6.1.4.1.321.100.2.12.1.1.9ColumnunitUtilitiesSaveConfigread-writecurrentThis field commands the unit to save its configuration.
1.3.6.1.4.1.321.100.2.12.1.1.10ColumnunitUtilitiesRestartStatusread-onlycurrentThis parameter indicates if the unit configuration needs to be saved and restarted. notNeeded - A save and restart is not needed at this time. recommended - A …
1.3.6.1.4.1.321.100.2.12.1.1.11ColumnunitUtilitiesReadOnlyPasswordread-writecurrentThe password for read only access to a device (VT100, front panel).
1.3.6.1.4.1.321.100.2.12.1.1.12ColumnunitUtilitiesPasswordLockoutEnableread-writecurrentThis parameter is used to enable or disable the password lockout feature.
1.3.6.1.4.1.321.100.2.12.1.1.13ColumnunitUtilitiesPasswordLockoutStatusread-onlycurrentThis parameter indicates if the password lockout feature is enabled or disabled, and if it is enabled this parameter may reflect if the password is indeed lock…
1.3.6.1.4.1.321.100.2.12.1.1.14ColumnunitUtilitiesPasswordLockoutClearread-writecurrentThis parameter is used to unlock a locked password.
1.3.6.1.4.1.321.100.2.13NodeproductInfo
1.3.6.1.4.1.321.100.2.13.1ScalarproductModelNumberread-onlycurrentThis string displays the units model number
1.3.6.1.4.1.321.100.2.13.2ScalarproductModelDescrread-onlycurrentThis string displays a brief description of the unit
1.3.6.1.4.1.321.100.2.13.3ScalarproductElementIdread-writecurrentThis string is the same information that is in the element id field located in the utilities Screen of the unit's user interface. This field can be set from ei…
1.3.6.1.4.1.321.100.2.13.4ScalarproductSoftwareRevread-onlycurrentThis string reports the units current software revision
1.3.6.1.4.1.321.100.2.13.5ScalarproductHardwareRevread-onlycurrentThis string reports the units hardware revision
1.3.6.1.4.1.321.100.2.13.6ScalarproductSerialNumread-onlycurrentThis string displays the unit's serial number
1.3.6.1.4.1.321.100.2.13.7ScalarproductPhysicalAddressread-onlycurrentThis string displays the unit's physical ethernet address
1.3.6.1.4.1.321.100.2.13.8ScalarproductNmsAddressread-onlycurrentThis string displays the unit's NMS address which is used to identify it to the TxPORT management products
1.3.6.1.4.1.321.100.2.13.9TableproductLabelTablenot-accessiblecurrentThe Product Label Table.
1.3.6.1.4.1.321.100.2.13.9.1RowproductLabelTableEntrynot-accessiblecurrentAn entry in the product label table.
1.3.6.1.4.1.321.100.2.13.9.1.1ColumnlabelTableIndexnot-accessiblecurrentThe index into the ProductLabelTable.
1.3.6.1.4.1.321.100.2.13.9.1.2ColumnlabelTableLabelread-writecurrentA product label.
1.3.6.1.4.1.321.100.2.13.9.1.3ColumnlabelTableValueread-writecurrentThe data associated with the label.
1.3.6.1.4.1.321.100.2.14NodenetAPS
1.3.6.1.4.1.321.100.2.14.1TablenetAPSConfigTablenot-accessiblecurrentOne to One network Automatic Protection Switching (APS) configuration parameters table.
1.3.6.1.4.1.321.100.2.14.1.1RownetAPSConfigTableEntrynot-accessiblecurrentAn entry in the netAPSConfigTable.
1.3.6.1.4.1.321.100.2.14.1.1.1ColumnnetAPSConfigNearIndexread-onlycurrentSelects the near device.
1.3.6.1.4.1.321.100.2.14.1.1.2ColumnnetAPSConfigFarIndexread-onlycurrentSelects the far device.
1.3.6.1.4.1.321.100.2.14.1.1.3ColumnnetAPSConfigifIndexread-onlycurrentSelects the MIB-II ifIndex.
1.3.6.1.4.1.321.100.2.14.1.1.4ColumnnetAPSConfigOtherifIndexread-writecurrentMIB-II ifIndex of the other interface involved with the APS.
1.3.6.1.4.1.321.100.2.14.1.1.5ColumnnetAPSConfigModeread-writecurrenttr54017 - Implements TR54017 autoABswitch - Implements a single ended A/B switch between two independent lines masterAltCarrier - Master side of alternate carr…
1.3.6.1.4.1.321.100.2.14.1.1.6ColumnnetAPSConfigRevertread-writecurrentdisabled - Service does not return to the primary line until the backup line fails. enabled - Service automatically returns to the primary line when the primar…
1.3.6.1.4.1.321.100.2.14.1.1.7ColumnnetAPSConfigManualInhibitread-writecurrentDisabled - Neither line is manually inhibited from carrying service. ThisLine - This line is manually inhibited from carrying service. OtherLine - The other li…
1.3.6.1.4.1.321.100.2.14.1.1.8ColumnnetAPSConfigAvailabilityTimerread-writecurrentThe line availability timer represents the minimum amount of time that is free of errors in active events that must expire before this line is returned to serv…
1.3.6.1.4.1.321.100.2.14.1.1.9ColumnnetAPSConfigESThresholdread-writecurrentThis parameter is the number of erred seconds in a 15-minute period needed before a transfer request is triggered. A setting of zero disables this trigger.
1.3.6.1.4.1.321.100.2.14.1.1.10ColumnnetAPSConfigESCountread-onlycurrentThis parameter is the number of erred seconds in the current 15-minute interval. This count is reset at the beginning of a new 15-minute interval.
1.3.6.1.4.1.321.100.2.14.1.1.11ColumnnetAPSConfigESSwitchEventread-onlycurrentThis status indicates if exceeding the ES threshold caused a transfer to the other line.
1.3.6.1.4.1.321.100.2.14.1.1.12ColumnnetAPSConfigCSESThresholdread-writecurrentThis parameter is the number of consecutive SES needed before a transfer request is triggered. A setting of zero disables this trigger.
1.3.6.1.4.1.321.100.2.14.1.1.13ColumnnetAPSConfigCSESCountread-onlycurrentThis parameter is the number of consecutive SES detected. This count stops when 900 is reached and is reset when a non-SES is detected.
1.3.6.1.4.1.321.100.2.14.1.1.14ColumnnetAPSConfigCSESSwitchEventread-onlycurrentThis status indicates if exceeding the consecutive SES threshold caused a transfer to the other line.
1.3.6.1.4.1.321.100.2.14.1.1.15ColumnnetAPSConfigStatusBitmapread-onlycurrentTR54017 defined bitmap status for this line interface: Value is 1 if this line is carrying service. Value is 2 if this line is in a failed state. Value is 4 if…
1.3.6.1.4.1.321.100.2.14.1.1.16ColumnnetAPSConfigStatusStringread-onlycurrentASCII string version of netAPSConfigStatusBitmap for this line status bits
1.3.6.1.4.1.321.100.2.14.1.1.17ColumnnetAPSConfigTimeInIntervalread-onlycurrentThe number of seconds into the netAPSHist24Table current interval.
1.3.6.1.4.1.321.100.2.14.1.1.18ColumnnetAPSConfigValidIntervalsread-onlycurrentThe number of valid intervals in the netAPSHist24Table
1.3.6.1.4.1.321.100.2.14.1.1.19ColumnnetAPSConfigValidDaysread-onlycurrentThe number of valid days in the netAPSHist30Table
1.3.6.1.4.1.321.100.2.14.1.1.20ColumnnetAPSConfigResetread-writecurrentThis action parameter does the following when the given value is set: other - Does nothing clearAlarms - Clear the APS events and counts clearHistory - Clear t…
1.3.6.1.4.1.321.100.2.14.2TablenetAPSHist24Tablenot-accessiblecurrentHistory table, contains Network APS historical data.
1.3.6.1.4.1.321.100.2.14.2.1RownetAPSHist24TableEntrynot-accessiblecurrentAn entry in the netAPSHist24Table.
1.3.6.1.4.1.321.100.2.14.2.1.1ColumnnetAPSHist24NearIndexread-onlycurrentSelects the near device.
1.3.6.1.4.1.321.100.2.14.2.1.2ColumnnetAPSHist24FarIndexread-onlycurrentSelects the far device.
1.3.6.1.4.1.321.100.2.14.2.1.3ColumnnetAPSHist24ifIndexread-onlycurrentSelects the MIB-II ifIndex.
1.3.6.1.4.1.321.100.2.14.2.1.4ColumnnetAPSHist24Indexread-onlycurrentThe index into the 24-hour history table.
1.3.6.1.4.1.321.100.2.14.2.1.5ColumnnetAPSHist24Timestampread-onlycurrentThe value of sysUpTime when the statistics were last updated.
1.3.6.1.4.1.321.100.2.14.2.1.6ColumnnetAPSHist24StatusBitmapread-onlycurrentTR54017 defined bitmap status for this line interface: Value is 1 if this line is carrying service. Value is 2 if this line is in a failed state. Value is 4 if…
1.3.6.1.4.1.321.100.2.14.2.1.7ColumnnetAPSHist24StatusStringread-onlycurrentASCII string version of netAPSHist24StatusBitmap for this line status bits
1.3.6.1.4.1.321.100.2.14.2.1.8ColumnnetAPSHist24Occurrencesread-onlycurrentThis parameter is the total number of times the service was transferred between lines.
1.3.6.1.4.1.321.100.2.14.2.1.9ColumnnetAPSHist24Durationread-onlycurrentThis parameter is the number of seconds the service was provided on this line.
1.3.6.1.4.1.321.100.2.14.3TablenetAPSHist30Tablenot-accessiblecurrentHistory table, contains Network APS 30-day historical data.
1.3.6.1.4.1.321.100.2.14.3.1RownetAPSHist30TableEntrynot-accessiblecurrentAn entry in the netAPSHist30Table.
1.3.6.1.4.1.321.100.2.14.3.1.1ColumnnetAPSHist30NearIndexread-onlycurrentSelects the near device.
1.3.6.1.4.1.321.100.2.14.3.1.2ColumnnetAPSHist30FarIndexread-onlycurrentSelects the far device.
1.3.6.1.4.1.321.100.2.14.3.1.3ColumnnetAPSHist30ifIndexread-onlycurrentSelects the MIB-II ifIndex.
1.3.6.1.4.1.321.100.2.14.3.1.4ColumnnetAPSHist30Indexread-onlycurrentThe index into the 30-day history table.
1.3.6.1.4.1.321.100.2.14.3.1.5ColumnnetAPSHist30Timestampread-onlycurrentThe value of sysUpTime when the statistics were last updated.
1.3.6.1.4.1.321.100.2.14.3.1.6ColumnnetAPSHist30StatusBitmapread-onlycurrentTR54017 defined bitmap status for this line interface: Value is 1 if this line is carrying service. Value is 2 if this line is in a failed state. Value is 4 if…
1.3.6.1.4.1.321.100.2.14.3.1.7ColumnnetAPSHist30StatusStringread-onlycurrentASCII string version of netAPSHist30StatusBitmap for this line status bits
1.3.6.1.4.1.321.100.2.14.3.1.8ColumnnetAPSHist30Occurrencesread-onlycurrentThis parameter is the total number of times the service was transferred between lines.
1.3.6.1.4.1.321.100.2.14.3.1.9ColumnnetAPSHist30Durationread-onlycurrentThis parameter is the number of seconds the service was provided on this line.