MIB Viewer

Dell-POE-MIB

34 objects
Add a new field in the PoE MIB to indicate Max power allocation allowed
Imported Objects
Dell-MIBrnd
SNMPv2-SMIMODULE-IDENTITY OBJECT-TYPE
SNMPv2-TCDisplayString TruthValue
OIDNameAccessStatusDescription
1.3.6.1.4.1.89.108IdentityrlPoeAdd a new field in the PoE MIB to indicate Max power allocation allowed
1.3.6.1.4.1.89.108.1TablerlPethPsePortTablenot-accessiblecurrentThe table listing additional information for Power Over Ethernet ports.
1.3.6.1.4.1.89.108.1.1RowrlPethPsePortEntrynot-accessiblecurrentAn entry in the rlPethPsePortTable.
1.3.6.1.4.1.89.108.1.1.1ColumnrlPethPsePortGroupIndexnot-accessiblecurrentThis variable uniquely identifies the group containing the port to which a power Ethernet PSE is connected. Group means box in the stack, module in a rack and …
1.3.6.1.4.1.89.108.1.1.2ColumnrlPethPsePortIndexnot-accessiblecurrentThis variable uniquely identifies the power Ethernet PSE port within group pethPsePortGroupIndex to which the power Ethernet PSE entry is connected.
1.3.6.1.4.1.89.108.1.1.3ColumnrlPethPsePortOutputVoltageread-onlycurrentThis variable indicates on the output voltage level in milli volts from rlPethPsePortIndex.
1.3.6.1.4.1.89.108.1.1.4ColumnrlPethPsePortOutputCurrentread-onlycurrentThis variable indicates on the output current level in milli amper from rlPethPsePortIndex.
1.3.6.1.4.1.89.108.1.1.5ColumnrlPethPsePortOutputPowerread-onlycurrentThis variable indicates on the output power level in milli watts from rlPethPsePortIndex.
1.3.6.1.4.1.89.108.1.1.6ColumnrlPethPsePortPowerLimitread-writecurrentThis variable indicates on the user configured power level in milli watts which is available from rlPethPsePortIndex.
1.3.6.1.4.1.89.108.1.1.7ColumnrlPethPsePortStatusread-onlycurrentThis variable indicates on the hardware status of rlPethPsePortIndex.
1.3.6.1.4.1.89.108.1.1.8ColumnrlPethPsePortStatusDescriptionread-onlycurrentThis variable indicates the description of the hardware status of rlPethPsePortIndex.
1.3.6.1.4.1.89.108.1.1.9ColumnrlPethPsePortOperPowerLimitread-onlycurrentThis variable indicates the maximum power level in milli watts which is available from rlPethPsePortIndex.
1.3.6.1.4.1.89.108.1.1.10ColumnrlPethPsePortSupportPoePlusread-onlycurrentThis variable indicates if the port supports poe plus.
1.3.6.1.4.1.89.108.1.1.11ColumnrlPethPsePortTimeRangeNameread-writecurrentThis variable is used to bind PoE port to time range.
1.3.6.1.4.1.89.108.1.1.12ColumnrlPethPsePortOperStatusread-onlycurrentThis Read-Only variable indicates PoE port current status affected by time range active/inactive and admin status.
1.3.6.1.4.1.89.108.1.1.13ColumnrlPethPsePortMaxPowerAllocAllowedread-onlycurrentThis variable indicates the maximum power allocation allowed per port (including wire power loses) in milli-watts which is available from rlPethPsePortIndex.
1.3.6.1.4.1.89.108.1.1.14ColumnrlPethPsePortSupportPoeread-onlycurrentThis variable indicates if the port is a poe port
1.3.6.1.4.1.89.108.2TablerlPethMainPseTablenot-accessiblecurrentThe table listing additional read - only information for Power Over Ethernet.
1.3.6.1.4.1.89.108.2.1RowrlPethMainPseEntrynot-accessiblecurrentAn entry in the rlPethMainPseTable.
1.3.6.1.4.1.89.108.2.1.1ColumnrlPethMainPseGroupIndexnot-accessiblecurrentThis variable uniquely identifies the group containing the port to which a power Ethernet PSE is connected. Group means box in the stack, module in a rack and …
1.3.6.1.4.1.89.108.2.1.2ColumnrlPethMainPseSwVersionread-onlycurrentThis variable identifies the MCU SW version.
1.3.6.1.4.1.89.108.2.1.3ColumnrlPethMainPseHwVersionread-onlycurrentThis variable identifies the MCU HW version.
1.3.6.1.4.1.89.108.2.1.4ColumnrlPethMainPseHwTyperead-onlycurrentThis variable identifies the MCU HW type (enhanced, plus, none).
1.3.6.1.4.1.89.108.2.1.5ColumnrlPethMainPsePowerGuardBandread-onlycurrentThis variable identifies the guard band in [W] for not connecting additional ports.
1.3.6.1.4.1.89.108.3TablerlPethPowerPseTablenot-accessiblecurrentThe table listing additional read-write information for Power Over Ethernet.
1.3.6.1.4.1.89.108.3.1RowrlPethPowerPseEntrynot-accessiblecurrentAn entry in the rlPethPowerPseTable.
1.3.6.1.4.1.89.108.3.1.1ColumnrlPethPowerPseGroupIndexnot-accessiblecurrentThis variable uniquely identifies the group containing the port to which a power Ethernet PSE is connected. Group means box in the stack, module in a rack and …
1.3.6.1.4.1.89.108.3.1.2ColumnrlPethPowerPsePowerread-writecurrentThis variable identifies the maximum power in [W] supplied by PSE.
1.3.6.1.4.1.89.108.3.1.3ColumnrlPethPowerPseRpsPowerread-writecurrentThis variable identifies the maximum power in [W] supplied by PSE + RPS.
1.3.6.1.4.1.89.108.3.1.4ColumnrlPethPowerPsePowerManagementModeread-writecurrentThis variable identifies power management mode.
1.3.6.1.4.1.89.108.3.1.5ColumnrlPethPowerPsedisconnectMethodread-writecurrentThis variable identifies disconnect method.
1.3.6.1.4.1.89.108.3.1.6ColumnrlPethPowerPseTemperatureSensorread-onlycurrentThis variable identifies the pd temperature sensor.
1.3.6.1.4.1.89.108.3.1.7ColumnrlPethPowerPseInrushTestEnabledread-writecurrentThis variable identifies if HW inrush test will be disabled. by default HW inrush test is enabled.
1.3.6.1.4.1.89.108.3.1.8ColumnrlPethPowerPseLegacyDisabledread-writecurrentThis variable identifies poe Legacy global configuration mode