MIB Viewer

EATON-PCD-MIB

51 objects
The MIB module for objects for common measures that most Eaton Power Chain Devices can support. Some portion of this MIB would be supported by most Eaton equipment, including Meters. This MIB covers three areas: - Voltage, Current, Frequency, and %Load measures. - Digital (binary) Inputs and Outputs. - Generic (non-specific) sensor readings. All objects are indexed by a device number, since some agents will present data from more than one Power Chain Device. This powerChainDeviceIndex is normally the same as entPhysicalIndex. Copyright (C) Eaton Corporation (2007-).
Imported Objects
OIDNameAccessStatusDescription
1.3.6.1.4.1.534.8.2IdentitypcdMIBThe MIB module for objects for common measures that most Eaton Power Chain Devices can support. Some portion of this MIB would be supported by most Eaton equip…
1.3.6.1.4.1.534.8.2.1NodepcdMIBObjects
1.3.6.1.4.1.534.8.2.1.1NodepcdMeasures
1.3.6.1.4.1.534.8.2.1.1.1TablepcdMeasuresTablenot-accessiblecurrentA table of measures for each device. Since these measures are not broken out by phase, they apply to all phases of the device.
1.3.6.1.4.1.534.8.2.1.1.1.1RowpcdMeasuresEntrynot-accessiblecurrentAn entry containing information applicable to a particular Power Chain Device.
1.3.6.1.4.1.534.8.2.1.1.1.1.1ColumnpowerChainDeviceIndexnot-accessiblecurrentThe Power Chain Device identifier (device number). Used to index all tables in this MIB. Normally equal to the device's entPhysicalIndex.
1.3.6.1.4.1.534.8.2.1.1.1.1.2ColumnpcdMeasuresMainVoltageread-onlycurrentThe present 'main' voltage for this device. The measure will be device-specific, eg, 3-phase average. The type of this measures is indicated by pcdMainVoltageT…
1.3.6.1.4.1.534.8.2.1.1.1.1.3ColumnpcdMainVoltageTyperead-onlycurrentIndicates what type of reading pcdMeasuresMainVoltage is. This may be units like 'Vrms Line-Line' or 'Vrms Line-Neutral', or the name of the source of this rea…
1.3.6.1.4.1.534.8.2.1.1.1.1.4ColumnpcdMeasuresSecondVoltageread-onlycurrentThe present 'second' voltage for this device. The measure will be device-specific, eg, 3-phase average. The type of this measures is indicated by pcdSecondVolt…
1.3.6.1.4.1.534.8.2.1.1.1.1.5ColumnpcdSecondVoltageTyperead-onlycurrentIndicates what type of reading pcdMeasuresSecondVoltage is. This may be units like 'Vrms Line-Line' or 'Vrms Line-Neutral', or the name of the source of this r…
1.3.6.1.4.1.534.8.2.1.1.1.1.6ColumnpcdMeasuresCurrentread-onlycurrentThe present summary current for this device. This may be the 3-phase average.
1.3.6.1.4.1.534.8.2.1.1.1.1.7ColumnpcdMeasuresPercentLoadread-onlycurrentThe percentage of the Power Chain Device's rated capacity presently being used.
1.3.6.1.4.1.534.8.2.1.1.1.1.8ColumnpcdMeasuresFrequencyread-onlycurrentThe present frequency reading for this Power Chain Device.
1.3.6.1.4.1.534.8.2.1.1.2TablepcdPhaseMeasuresTablenot-accessiblecurrentA table of per-phase measures for each device.
1.3.6.1.4.1.534.8.2.1.1.2.1RowpcdPhaseMeasuresEntrynot-accessiblecurrentAn entry containing information applicable to one line of a particular Power Chain Device. Indexed by device number and phase number.
1.3.6.1.4.1.534.8.2.1.1.2.1.1ColumnpcdPhaseIndexnot-accessiblecurrentThe line (phase) identifier.
1.3.6.1.4.1.534.8.2.1.1.2.1.2ColumnpcdPhaseMeasuresVoltageLLread-onlycurrentThe present Line-to-Line voltage for this phase of this device.
1.3.6.1.4.1.534.8.2.1.1.2.1.3ColumnpcdPhaseMeasuresVoltageLNread-onlycurrentThe present Line-to-Neutral voltage for this phase of this device.
1.3.6.1.4.1.534.8.2.1.1.2.1.4ColumnpcdPhaseMeasuresCurrentread-onlycurrentThe present current for this phase of this device.
1.3.6.1.4.1.534.8.2.1.1.2.1.5ColumnpcdPhaseMeasuresPercentLoadread-onlycurrentThe percentage of this phase's rated capacity presently being used.
1.3.6.1.4.1.534.8.2.1.2NodepcdDigitalIO
1.3.6.1.4.1.534.8.2.1.2.1TablepcdDigitalInputsTablenot-accessiblecurrentA table of digital inputs for the indicated device. Devices will have varying numbers of digital inputs, from 1 to 64, but most commonly 1-4. The table will no…
1.3.6.1.4.1.534.8.2.1.2.1.1RowpcdDigitalInputsEntrynot-accessiblecurrentAn entry containing information applicable to a particular digital input of a Power Chain Device.
1.3.6.1.4.1.534.8.2.1.2.1.1.1ColumnpcdDigitalInputIndexnot-accessiblecurrentThe index of this digital input.
1.3.6.1.4.1.534.8.2.1.2.1.1.2ColumnpcdDigitalInputNameread-onlycurrentThe name of this digital input as a human-readable text string.
1.3.6.1.4.1.534.8.2.1.2.1.1.3ColumnpcdDigitalInputPresentValueread-onlycurrentThe present value of this digital input, presented as a human-readable text string. This value should be one of the states listed in pcdDigitalInputPossibleVal…
1.3.6.1.4.1.534.8.2.1.2.1.1.4ColumnpcdDigitalInputPossibleValuesread-onlycurrentThe possible states of this digital input, listed as a semicolon separated string of values. A simple default is True;False, but most devices should provide mo…
1.3.6.1.4.1.534.8.2.1.2.1.1.5ColumnpcdDigitalInputLastChangeread-onlycurrentIndicates (in text) the date and time when pcdDigitalInputPresentValue last changed its state.
1.3.6.1.4.1.534.8.2.1.2.2TablepcdDigitalOutputsTablenot-accessiblecurrentA table of digital outputs for the indicated device. Devices will have varying numbers of digital outputs, from 1 to 64, but most commonly 1-4. The table will …
1.3.6.1.4.1.534.8.2.1.2.2.1RowpcdDigitalOutputsEntrynot-accessiblecurrentAn entry containing information applicable to a particular digital output of a Power Chain Device.
1.3.6.1.4.1.534.8.2.1.2.2.1.1ColumnpcdDigitalOutputIndexnot-accessiblecurrentThe index of this digital output.
1.3.6.1.4.1.534.8.2.1.2.2.1.2ColumnpcdDigitalOutputNameread-onlycurrentThe name of this digital output as a human-readable text string.
1.3.6.1.4.1.534.8.2.1.2.2.1.3ColumnpcdDigitalOutputPresentValueread-writecurrentWhen read, gives the present value of this digital output, presented as a human-readable text string. When written, sets the digital output to the indicated st…
1.3.6.1.4.1.534.8.2.1.2.2.1.4ColumnpcdDigitalOutputPossibleValuesread-onlycurrentThe possible states of this digital output, listed as a semicolon separated string of values. A simple default is True;False, but most devices should provide m…
1.3.6.1.4.1.534.8.2.1.2.2.1.5ColumnpcdDigitalOutputLastChangeread-onlycurrentIndicates (in text) the date and time when pcdDigitalOutputPresentValue last changed its state.
1.3.6.1.4.1.534.8.2.1.3NodepcdSensors
1.3.6.1.4.1.534.8.2.1.3.1TablepcdSensorTablenot-accessiblecurrentA table of additional non-specific sensor measures for each device.
1.3.6.1.4.1.534.8.2.1.3.1.1RowpcdSensorEntrynot-accessiblecurrentAn entry containing information for one sensor reading in a Power Chain Device. Indexed by device number and a sensor index.
1.3.6.1.4.1.534.8.2.1.3.1.1.1ColumnpcdSensorIndexnot-accessiblecurrentA simple index to separate pcdSensorEntry rows. This index has no specific meaning; it is normally just a consecutive numbering of sensor reading rows for a gi…
1.3.6.1.4.1.534.8.2.1.3.1.1.2ColumnpcdSensorNameread-onlycurrentThe name of this sensor readings as a human-readable text string.
1.3.6.1.4.1.534.8.2.1.3.1.1.3ColumnpcdSensorReadingread-onlycurrentThe present reading of this sensor.
1.3.6.1.4.1.534.8.2.1.3.1.1.4ColumnpcdSensorUnitsread-onlycurrentText string which indicates the units for this pcdSensorEntry, including any scaling factor to convert pcdSensorReading to an Integer32 value.
1.3.6.1.4.1.534.8.2.2NodepcdConformance
1.3.6.1.4.1.534.8.2.2.1GrouppcdMeasuresRowcurrentThe pcdMeasuresEntry objects that are accessible to MIB browsers.
1.3.6.1.4.1.534.8.2.2.2GrouppcdPhaseMeasuresRowcurrentThe pcdPhaseMeasuresEntry objects that are accessible to MIB browsers.
1.3.6.1.4.1.534.8.2.2.3GrouppcdDigitalInputRowcurrentThe pcdDigitalInputsEntry objects that are accessible to MIB browsers.
1.3.6.1.4.1.534.8.2.2.4GrouppcdDigitalOutputRowcurrentThe pcdDigitalOutputsEntry objects that are accessible to MIB browsers.
1.3.6.1.4.1.534.8.2.2.5GrouppcdSensorRowcurrentThe pcdSensorEntry objects that are accessible to MIB browsers.
1.3.6.1.4.1.534.8.2.2.11CompliancepcdMeasuresCompliancecurrentThe compliance statement for Power Chain Device implementations that support pcdMeasures.
1.3.6.1.4.1.534.8.2.2.12CompliancepcdDigitalIOCompliancecurrentThe compliance statement for Power Chain Device implementations that support the pcdDigitalIO tables.
1.3.6.1.4.1.534.8.2.2.13CompliancepcdSensorsCompliancecurrentThe compliance statement for Power Chain Device implementations that support the pcdSensorTable.