EATON-SENSOR-MIB
148 objects
The MIB module for Eaton Sensors.
Imported Objects
| EATON-OIDS | sensorAgent |
| SNMPv2-CONF | MODULE-COMPLIANCE NOTIFICATION-GROUP OBJECT-GROUP |
| SNMPv2-SMI | Counter32 Integer32 MODULE-IDENTITY NOTIFICATION-TYPE OBJECT-TYPE |
| SNMPv2-TC | TEXTUAL-CONVENTION |
| OID | Name | Access | Status | Description |
|---|---|---|---|---|
| 1.3.6.1.4.1.534.6.8.1 | IdentityeatonSensor | The MIB module for Eaton Sensors. | ||
| 1.3.6.1.4.1.534.6.8.1.1 | Nodesensor | |||
| 1.3.6.1.4.1.534.6.8.1.1.0 | NodesensorNotification | |||
| 1.3.6.1.4.1.534.6.8.1.1.0.1 | NotificationnotifySensorCount | current | Sent whenever the sensor count changes after a discovery or removing from the UI. | |
| 1.3.6.1.4.1.534.6.8.1.1.0.2 | NotificationnotifySensorStatus | current | Sent whenever the sensor status changes. | |
| 1.3.6.1.4.1.534.6.8.1.1.1 | ScalarsensorCount | read-only | current | Number of sensor managed on this device. |
| 1.3.6.1.4.1.534.6.8.1.1.2 | TablesensorIdentificationTable | not-accessible | current | A list of sensor devices identification data. The number of entries is given by sensorCount. |
| 1.3.6.1.4.1.534.6.8.1.1.2.1 | RowsensorIdentificationEntry | not-accessible | current | An entry for a sensor device identification. |
| 1.3.6.1.4.1.534.6.8.1.1.2.1.1 | ColumnsensorIndex | accessible-for-notify | current | A unique value for each sensor device. Its value ranges from 1 to sensorCount. |
| 1.3.6.1.4.1.534.6.8.1.1.2.1.2 | ColumnsensorUuid | read-only | current | A unique uuid value for each sensor device. |
| 1.3.6.1.4.1.534.6.8.1.1.2.1.3 | ColumnsensorConnectionType | read-only | current | Sensor connection type with the device that monitors it. |
| 1.3.6.1.4.1.534.6.8.1.1.2.1.4 | ColumnsensorAddress | read-only | current | Depending of the connection implementation : Modbus Slave Id, BT Mac address, ... |
| 1.3.6.1.4.1.534.6.8.1.1.2.1.5 | ColumnsensorMonitoredBy | read-only | current | Parent oid device where the sensor is connected to and monitored by. |
| 1.3.6.1.4.1.534.6.8.1.1.2.1.6 | ColumnsensorManufacturer | read-only | current | The vendor name of the sensor device. |
| 1.3.6.1.4.1.534.6.8.1.1.2.1.7 | ColumnsensorModel | read-only | current | The model name of the sensor device. |
| 1.3.6.1.4.1.534.6.8.1.1.2.1.8 | ColumnsensorPartNumber | read-only | current | The catalog part number of the sensor device. |
| 1.3.6.1.4.1.534.6.8.1.1.2.1.9 | ColumnsensorSerialNumber | read-only | current | The serial number of the sensor device. |
| 1.3.6.1.4.1.534.6.8.1.1.2.1.10 | ColumnsensorFirmwareVersion | read-only | current | The firmware version of the sensor device. |
| 1.3.6.1.4.1.534.6.8.1.1.3 | TablesensorConfigurationTable | not-accessible | current | A list of sensor devices configuration data. The number of entries is given by sensorCount. |
| 1.3.6.1.4.1.534.6.8.1.1.3.1 | RowsensorConfigurationEntry | not-accessible | current | An entry for a sensor device configuration. |
| 1.3.6.1.4.1.534.6.8.1.1.3.1.1 | ColumnsensorName | read-write | current | The friendly name of the sensor device. |
| 1.3.6.1.4.1.534.6.8.1.1.3.1.2 | ColumnsensorLocation | read-write | current | The location of the sensor device. |
| 1.3.6.1.4.1.534.6.8.1.1.3.1.3 | ColumnsensorPosition | read-write | current | The Position by reference to the data center aisle. |
| 1.3.6.1.4.1.534.6.8.1.1.3.1.4 | ColumnsensorElevation | read-write | current | The Elevation in the rack. |
| 1.3.6.1.4.1.534.6.8.1.1.3.1.5 | ColumnsensorUElevation | read-write | current | The elevation in the rack in count of U position from the bottom. |
| 1.3.6.1.4.1.534.6.8.1.1.4 | TablesensorMonitoringTable | not-accessible | current | A list of sensor devices monitoring data. The number of entries is given by sensorCount. |
| 1.3.6.1.4.1.534.6.8.1.1.4.1 | RowsensorMonitoringEntry | not-accessible | current | An entry for a sensor device monitoring. |
| 1.3.6.1.4.1.534.6.8.1.1.4.1.1 | ColumnsensorStatus | read-only | current | Indicates how the sensor is communicating or not. |
| 1.3.6.1.4.1.534.6.8.1.1.4.1.2 | ColumnsensorStatusSince | read-only | current | UTC time in seconds since 1970/01/01 dating the sensor status last change. |
| 1.3.6.1.4.1.534.6.8.1.1.4.1.3 | ColumnsensorTemperatureCount | read-only | current | Number of temperature probes managed by the sensor device. |
| 1.3.6.1.4.1.534.6.8.1.1.4.1.4 | ColumnsensorHumidityCount | read-only | current | Number of humidity probes managed by the sensor device. |
| 1.3.6.1.4.1.534.6.8.1.1.4.1.5 | ColumnsensorDigitalInputCount | read-only | current | Number of digital input probes managed by the sensor device. |
| 1.3.6.1.4.1.534.6.8.1.1.4.1.6 | ColumnsensorAnalogInputCount | read-only | current | Number of analog input probes managed by the sensor device. |
| 1.3.6.1.4.1.534.6.8.1.2 | Nodetemperature | |||
| 1.3.6.1.4.1.534.6.8.1.2.0 | NodetemperatureNotification | |||
| 1.3.6.1.4.1.534.6.8.1.2.0.1 | NotificationnotifyTemperatureAlarm | current | Sent whenever the temperature alarm changes. | |
| 1.3.6.1.4.1.534.6.8.1.2.0.2 | NotificationnotifyTemperatureCommunicationStatus | current | Sent whenever the temperature communication status changes. Is not implemented when the probe is internal (see temperatureConnectionType). | |
| 1.3.6.1.4.1.534.6.8.1.2.1 | TabletemperatureIdentificationTable | not-accessible | current | A list of temperature probe measurements. the number of entries is given by the temperature count. |
| 1.3.6.1.4.1.534.6.8.1.2.1.1 | RowtemperatureIdentificationEntry | not-accessible | current | An entry for a temperature probe identification. |
| 1.3.6.1.4.1.534.6.8.1.2.1.1.1 | ColumntemperatureIndex | accessible-for-notify | current | A unique value for each temperature probe measurement. Its value ranges from 1 to sensorTemperatureCount. |
| 1.3.6.1.4.1.534.6.8.1.2.1.1.2 | ColumntemperatureUuid | read-only | current | A unique uuid value for each temperature. |
| 1.3.6.1.4.1.534.6.8.1.2.1.1.3 | ColumntemperatureConnectionType | read-only | current | Probe connection type with the sensor that monitors it. |
| 1.3.6.1.4.1.534.6.8.1.2.2 | TabletemperatureConfigurationTable | not-accessible | current | A list of temperature probe configuration. The number of entries is given by sensorTemperatureCount. |
| 1.3.6.1.4.1.534.6.8.1.2.2.1 | RowtemperatureConfigurationEntry | not-accessible | current | An entry for a temperature probe configuration. |
| 1.3.6.1.4.1.534.6.8.1.2.2.1.1 | ColumntemperatureName | read-write | current | The friendly name of the sensor temperature probe. |
| 1.3.6.1.4.1.534.6.8.1.2.2.1.2 | ColumntemperatureEnable | read-write | current | Configure the temperature acquired or not. 0:disabled, 1:enabled |
| 1.3.6.1.4.1.534.6.8.1.2.2.1.3 | ColumntemperatureOffset | read-write | current | Configure the offset (Minus or Plus) to be added to the acquired value in order to correct the probe measurement error. See temperatureUnit data for the units. |
| 1.3.6.1.4.1.534.6.8.1.2.2.1.4 | ColumntemperatureAlarmEnable | read-write | current | Configure the temperature alarm depending on the thresholds evaluated or not. 0:disabled, 1:enabled |
| 1.3.6.1.4.1.534.6.8.1.2.2.1.5 | ColumntemperatureThresholdLowWarning | read-write | current | Low warning temperature threshold. See temperatureUnit data for the units. |
| 1.3.6.1.4.1.534.6.8.1.2.2.1.6 | ColumntemperatureThresholdLowCritical | read-write | current | Low critical temperature threshold. See temperatureUnit data for the units. |
| 1.3.6.1.4.1.534.6.8.1.2.2.1.7 | ColumntemperatureThresholdHighWarning | read-write | current | High warning temperature threshold. See temperatureUnit data for the units. |
| 1.3.6.1.4.1.534.6.8.1.2.2.1.8 | ColumntemperatureThresholdHighCritical | read-write | current | High critical temperature threshold. See temperatureUnit data for the units. |
| 1.3.6.1.4.1.534.6.8.1.2.2.1.9 | ColumntemperatureThresholdHysteresis | read-write | current | Temperature threshold hysteresis. See temperatureUnit data for the units. |
| 1.3.6.1.4.1.534.6.8.1.2.2.1.10 | ColumntemperatureAlarmGracePeriod | read-write | current | The grace period the alarm triggers after the acquired value crosses a trigger value (in seconds). |
| 1.3.6.1.4.1.534.6.8.1.2.3 | TabletemperatureMonitoringTable | not-accessible | current | A list of temperature probe monitoring. The number of entries is given by sensorTemperatureCount. |
| 1.3.6.1.4.1.534.6.8.1.2.3.1 | RowtemperatureMonitoringEntry | not-accessible | current | An entry for a temperature probe monitoring. |
| 1.3.6.1.4.1.534.6.8.1.2.3.1.1 | ColumntemperatureAlarm | read-only | current | Alarm set according to the realtime measure compared to the thresholds. |
| 1.3.6.1.4.1.534.6.8.1.2.3.1.2 | ColumntemperatureAlarmChangeSince | read-only | current | UTC time in seconds since 1970/01/01 dating the temperature alarm last change. |
| 1.3.6.1.4.1.534.6.8.1.2.3.1.3 | ColumntemperatureValue | read-only | current | Realtime measured value after correction with the offset. See temperatureUnit data for the units. |
| 1.3.6.1.4.1.534.6.8.1.2.3.1.4 | ColumntemperatureCommunicationStatus | read-only | current | Indicates how the temperature probe is communicating or not. |
| 1.3.6.1.4.1.534.6.8.1.2.3.1.5 | ColumntemperatureCommunicationStatusSince | read-only | current | UTC time in seconds since 1970/01/01 dating the temperature communication status last change. |
| 1.3.6.1.4.1.534.6.8.1.2.4 | TabletemperatureMonitoringMinMaxTable | not-accessible | current | A list of temperature probe monitoring Min and Max. The number of entries is given by sensorTemperatureCount. |
| 1.3.6.1.4.1.534.6.8.1.2.4.1 | RowtemperatureMonitoringMinMaxEntry | not-accessible | current | An entry for a temperature probe monitoring Min and Max. |
| 1.3.6.1.4.1.534.6.8.1.2.4.1.1 | ColumntemperatureMinValue | read-only | current | Minimum value registered since the 1st connection of the sensor or the last reset. See temperatureUnit data for the units. |
| 1.3.6.1.4.1.534.6.8.1.2.4.1.2 | ColumntemperatureMinValueSince | read-only | current | UTC time in seconds since 1970/01/01 dating the temperature min value last change. |
| 1.3.6.1.4.1.534.6.8.1.2.4.1.3 | ColumntemperatureMaxValue | read-only | current | Maximum value registered since the 1st connection of the sensor or the last reset. See temperatureUnit data for the units. |
| 1.3.6.1.4.1.534.6.8.1.2.4.1.4 | ColumntemperatureMaxValueSince | read-only | current | UTC time in seconds since 1970/01/01 dating the temperature max value last change. |
| 1.3.6.1.4.1.534.6.8.1.2.4.1.5 | ColumntemperatureResetMinMax | read-write | current | Command that resets the min and max data with the current measure. 0:None, 1:Reset |
| 1.3.6.1.4.1.534.6.8.1.2.5 | ScalartemperatureUnit | read-write | current | Temperature unit configuration. It is a global setting for all the v1 and v3 SNMP client. It does not involve the temperature unit of data stored and managed i… |
| 1.3.6.1.4.1.534.6.8.1.3 | Nodehumidity | |||
| 1.3.6.1.4.1.534.6.8.1.3.0 | NodehumidityNotification | |||
| 1.3.6.1.4.1.534.6.8.1.3.0.1 | NotificationnotifyHumidityAlarm | current | Sent whenever the humidity alarm changes. | |
| 1.3.6.1.4.1.534.6.8.1.3.0.2 | NotificationnotifyHumidityCommunicationStatus | current | Sent whenever the humidity communication status changes. Is not implemented when the probe is internal (see humidityConnectionType). | |
| 1.3.6.1.4.1.534.6.8.1.3.1 | TablehumidityIdentificationTable | not-accessible | current | A list of humidity probe measurements. the number of entries is given by the humidity count. |
| 1.3.6.1.4.1.534.6.8.1.3.1.1 | RowhumidityIdentificationEntry | not-accessible | current | An entry for a humidity probe identification. |
| 1.3.6.1.4.1.534.6.8.1.3.1.1.1 | ColumnhumidityIndex | accessible-for-notify | current | A unique value for each humidity probe measurement. Its value ranges from 1 to sensorhumidityCount. |
| 1.3.6.1.4.1.534.6.8.1.3.1.1.2 | ColumnhumidityUuid | read-only | current | A unique uuid value for each humidity. |
| 1.3.6.1.4.1.534.6.8.1.3.1.1.3 | ColumnhumidityConnectionType | read-only | current | Probe connection type with the sensor that monitors it. |
| 1.3.6.1.4.1.534.6.8.1.3.2 | TablehumidityConfigurationTable | not-accessible | current | A list of humidity probe configuration. The number of entries is given by sensorhumidityCount. |
| 1.3.6.1.4.1.534.6.8.1.3.2.1 | RowhumidityConfigurationEntry | not-accessible | current | An entry for a humidity probe configuration. |
| 1.3.6.1.4.1.534.6.8.1.3.2.1.1 | ColumnhumidityName | read-write | current | The friendly name of the sensor humidity probe. |
| 1.3.6.1.4.1.534.6.8.1.3.2.1.2 | ColumnhumidityEnable | read-write | current | Configure the humidity acquired or not. 0:disabled, 1:enabled |
| 1.3.6.1.4.1.534.6.8.1.3.2.1.3 | ColumnhumidityOffset | read-write | current | Configure the offset (Minus or Plus) to be added to the acquired value in order to correct the probe measurement error. in tenth of % units. |
| 1.3.6.1.4.1.534.6.8.1.3.2.1.4 | ColumnhumidityAlarmEnable | read-write | current | Configure the humidity alarm depending on the thresholds evaluated or not. 0:disabled, 1:enabled |
| 1.3.6.1.4.1.534.6.8.1.3.2.1.5 | ColumnhumidityThresholdLowWarning | read-write | current | Low warning humidity threshold in tenth of % units. |
| 1.3.6.1.4.1.534.6.8.1.3.2.1.6 | ColumnhumidityThresholdLowCritical | read-write | current | Low critical humidity threshold in tenth of % units. |
| 1.3.6.1.4.1.534.6.8.1.3.2.1.7 | ColumnhumidityThresholdHighWarning | read-write | current | High warning humidity threshold in tenth of % units. |
| 1.3.6.1.4.1.534.6.8.1.3.2.1.8 | ColumnhumidityThresholdHighCritical | read-write | current | High critical humidity threshold in tenth of % units. |
| 1.3.6.1.4.1.534.6.8.1.3.2.1.9 | ColumnhumidityThresholdHysteresis | read-write | current | humidity threshold hysteresis in tenth of % units. |
| 1.3.6.1.4.1.534.6.8.1.3.2.1.10 | ColumnhumidityAlarmGracePeriod | read-write | current | The grace period the alarm triggers after the acquired value crosses a trigger value (in seconds). |
| 1.3.6.1.4.1.534.6.8.1.3.3 | TablehumidityMonitoringTable | not-accessible | current | A list of humidity probe monitoring. The number of entries is given by sensorhumidityCount. |
| 1.3.6.1.4.1.534.6.8.1.3.3.1 | RowhumidityMonitoringEntry | not-accessible | current | An entry for a humidity probe monitoring. |
| 1.3.6.1.4.1.534.6.8.1.3.3.1.1 | ColumnhumidityAlarm | read-only | current | Alarm set according to the realtime measure compared to the thresholds. |
| 1.3.6.1.4.1.534.6.8.1.3.3.1.2 | ColumnhumidityAlarmChangeSince | read-only | current | UTC time in seconds since 1970/01/01 dating the humidity alarm last change. |
| 1.3.6.1.4.1.534.6.8.1.3.3.1.3 | ColumnhumidityValue | read-only | current | Realtime measured value after correction with the offset. in tenth of % units. |
| 1.3.6.1.4.1.534.6.8.1.3.3.1.4 | ColumnhumidityCommunicationStatus | read-only | current | Indicates how the humidity probe is communicating or not. |
| 1.3.6.1.4.1.534.6.8.1.3.3.1.5 | ColumnhumidityCommunicationStatusSince | read-only | current | UTC time in seconds since 1970/01/01 dating the humidity communication status last change. |
| 1.3.6.1.4.1.534.6.8.1.3.4 | TablehumidityMonitoringMinMaxTable | not-accessible | current | A list of humidity probe monitoring Min and Max. The number of entries is given by sensorhumidityCount. |
| 1.3.6.1.4.1.534.6.8.1.3.4.1 | RowhumidityMonitoringMinMaxEntry | not-accessible | current | An entry for a humidity probe monitoring Min and Max. |
| 1.3.6.1.4.1.534.6.8.1.3.4.1.1 | ColumnhumidityMinValue | read-only | current | Minimum value registered since the 1st connection of the sensor or the last reset. in tenth of % units. |
| 1.3.6.1.4.1.534.6.8.1.3.4.1.2 | ColumnhumidityMinValueSince | read-only | current | UTC time in seconds since 1970/01/01 dating the humidity min value last change. |
| 1.3.6.1.4.1.534.6.8.1.3.4.1.3 | ColumnhumidityMaxValue | read-only | current | Maximum value registered since the 1st connection of the sensor or the last reset. in tenth of % units. |
| 1.3.6.1.4.1.534.6.8.1.3.4.1.4 | ColumnhumidityMaxValueSince | read-only | current | UTC time in seconds since 1970/01/01 dating the humidity max value last change. |
| 1.3.6.1.4.1.534.6.8.1.3.4.1.5 | ColumnhumidityResetMinMax | read-write | current | Command that resets the min and max data with the current measure. 0:None, 1:Reset |
| 1.3.6.1.4.1.534.6.8.1.4 | NodedigitalInput | |||
| 1.3.6.1.4.1.534.6.8.1.4.0 | NodedigitalInputNotification | |||
| 1.3.6.1.4.1.534.6.8.1.4.0.1 | NotificationnotifyDigitalInputAlarm | current | Sent whenever the digital input alarm changes. | |
| 1.3.6.1.4.1.534.6.8.1.4.0.2 | NotificationnotifydigitalInputCommunicationStatus | current | Sent whenever the digital input communication status changes. Is not implemented when the probe is internal (see digitalInputConnectionType). | |
| 1.3.6.1.4.1.534.6.8.1.4.1 | TabledigitalInputIdentificationTable | not-accessible | current | A list of digital input probe measurements. The number of entries is given by sensorDigitalInputCount. |
| 1.3.6.1.4.1.534.6.8.1.4.1.1 | RowdigitalInputIdentificationEntry | not-accessible | current | An entry for a digital input identification. |
| 1.3.6.1.4.1.534.6.8.1.4.1.1.1 | ColumndigitalInputIndex | accessible-for-notify | current | A unique value for each digital input probe measurement. Its value ranges from 1 to sensorDigitalInputCount. |
| 1.3.6.1.4.1.534.6.8.1.4.1.1.2 | ColumndigitalInputUuid | read-only | current | A unique uuid value for each digital Input. |
| 1.3.6.1.4.1.534.6.8.1.4.1.1.3 | ColumndigitalInputConnectionType | read-only | current | Probe connection type with the sensor that monitors it. |
| 1.3.6.1.4.1.534.6.8.1.4.2 | TabledigitalInputConfigurationTable | not-accessible | current | A list of digital input probe configuration. The number of entries is given by sensorDigitalInputCount. |
| 1.3.6.1.4.1.534.6.8.1.4.2.1 | RowdigitalInputConfigurationEntry | not-accessible | current | An entry for a digital input probe configuration. |
| 1.3.6.1.4.1.534.6.8.1.4.2.1.1 | ColumndigitalInputName | read-write | current | The friendly name of the digital input probe. |
| 1.3.6.1.4.1.534.6.8.1.4.2.1.2 | ColumndigitalInputEnable | read-write | current | Configure the digital input acquired or not. 0:disabled, 1:enabled |
| 1.3.6.1.4.1.534.6.8.1.4.2.1.3 | ColumndigitalInputPolarity | read-write | current | Configure the digitalInput polarity. 0 : Normally opened, 1 : Normally closed |
| 1.3.6.1.4.1.534.6.8.1.4.2.1.4 | ColumndigitalInputAlarmEnable | read-write | current | Configure the digitalInput alarm depending on the polarity evaluated or not. 0:disabled, 1:enabled |
| 1.3.6.1.4.1.534.6.8.1.4.2.1.5 | ColumndigitalInputAlarmSeverity | read-write | current | Configure the alarm severity. |
| 1.3.6.1.4.1.534.6.8.1.4.2.1.6 | ColumndigitalInputAlarmGracePeriod | read-write | current | The delay the alarm triggers when the state change event occurs (in seconds). |
| 1.3.6.1.4.1.534.6.8.1.4.3 | TabledigitalInputMonitoringTable | not-accessible | current | A list of digital input probee monitoring. The number of entries is given by sensorDigitalInputCount. |
| 1.3.6.1.4.1.534.6.8.1.4.3.1 | RowdigitalInputMonitoringEntry | not-accessible | current | An entry for a digital Input probe. |
| 1.3.6.1.4.1.534.6.8.1.4.3.1.1 | ColumndigitalInputAlarm | read-only | current | Alarm set according to the polarity and alarm severity configuration. |
| 1.3.6.1.4.1.534.6.8.1.4.3.1.2 | ColumndigitalInputAlarmChangeSince | read-only | current | UTC time in seconds since 1970/01/01 dating the digital input alarm last change. |
| 1.3.6.1.4.1.534.6.8.1.4.3.1.3 | ColumndigitalInputState | read-only | current | Measure of the digital input after applying the polarity configured. 0 : Inactive, 1 : Active |
| 1.3.6.1.4.1.534.6.8.1.4.3.1.4 | ColumndigitalInputStateSince | read-only | current | UTC time in seconds since 1970/01/01 dating the digital input state last change. |
| 1.3.6.1.4.1.534.6.8.1.4.3.1.5 | ColumndigitalInputCommunicationStatus | read-only | current | Indicates how the digital input is communicating or not. |
| 1.3.6.1.4.1.534.6.8.1.4.3.1.6 | ColumndigitalInputCommunicationStatusSince | read-only | current | UTC time in seconds since 1970/01/01 dating the digital input communication status last change. |
| 1.3.6.1.4.1.534.6.8.1.10 | Nodeconformance | |||
| 1.3.6.1.4.1.534.6.8.1.10.1 | ComplianceeatonSensorCompliances | current | The requirements for conforming to the Sensor MIB. | |
| 1.3.6.1.4.1.534.6.8.1.10.2 | NodeobjectGroups | |||
| 1.3.6.1.4.1.534.6.8.1.10.2.1 | GroupsensorRequiredGroup | current | These objects are required to conform to this MIB. | |
| 1.3.6.1.4.1.534.6.8.1.10.2.2 | GroupsensorOptionalGroup | current | These objects in this MIB are optional. | |
| 1.3.6.1.4.1.534.6.8.1.10.2.3 | GroupsensorNotifyGroup | current | These notifications will be supported depending on the features of the sensor. |
Type Definitions
| Name | Syntax | Status | Description |
|---|---|---|---|
| AlarmLevelType | INTEGER { good(0), informational(1), warning(2), critical(3) } | current | Describes the alarm level. |
| AlarmSeverityType | INTEGER { informational(1), warning(2), critical(3) } | current | Describes the alarm severity. |
| AlarmType | INTEGER { good(0), lowWarning(1), lowCritical(2), highWarning(3), highCritical(4) } | current | Describes the alarm according to a measured value by reference to the triggers. |
| CommunicationStatus | INTEGER { unknown(0), communicationOK(2), communicationLost(3) } | current | Describes the communication sensor status or probe status. |
| ElevationType | INTEGER { undefined(0), other(1), bottom(2), middle(3), top(4) } | current | Describes the elevation in the rack. |
| EnableType | INTEGER { disabled(0), enabled(1) } | current | Describes enable/disable. |
| PolarityType | INTEGER { normallyOpened(0), normallyClosed(1) } | current | Describes the polarity configuration. |
| PositionType | INTEGER { undefined(0), other(1), rackRear(2), rackFront(3), batteryRoom(4) } | current | Describes the position by reference to the data center aisle. |
| ProbeConnectionType | INTEGER { undefined(0), internal(1), wired(2), wireless(3) } | current | Describes the probe connection to the sensor or probe. |
| ResetCommandType | INTEGER { none(0), reset(1) } | current | Commands a reset. |
| StateType | INTEGER { inactive(0), active(1) } | current | Describes the state of a digital input that depends on its measure and the polrity configuration. |
| TemperatureUnitType | INTEGER { tenthOfDegKelvin(0), tenthOfDegCelsius(1), tenthOfDegFarhenheit(2) } | current | Describes the temperature unit used to read/write the temperature data. |
| UnixTimeStamp | Counter32 | current | Unix time stamp. Measured in seconds since January 1, 1970. |