MIB Viewer

EATON-SENSOR-MIB

148 objects
The MIB module for Eaton Sensors.
Imported Objects
EATON-OIDSsensorAgent
SNMPv2-CONFMODULE-COMPLIANCE NOTIFICATION-GROUP OBJECT-GROUP
SNMPv2-SMICounter32 Integer32 MODULE-IDENTITY NOTIFICATION-TYPE OBJECT-TYPE
SNMPv2-TCTEXTUAL-CONVENTION
OIDNameAccessStatusDescription
1.3.6.1.4.1.534.6.8.1IdentityeatonSensorThe MIB module for Eaton Sensors.
1.3.6.1.4.1.534.6.8.1.1Nodesensor
1.3.6.1.4.1.534.6.8.1.1.0NodesensorNotification
1.3.6.1.4.1.534.6.8.1.1.0.1NotificationnotifySensorCountcurrentSent whenever the sensor count changes after a discovery or removing from the UI.
1.3.6.1.4.1.534.6.8.1.1.0.2NotificationnotifySensorStatuscurrentSent whenever the sensor status changes.
1.3.6.1.4.1.534.6.8.1.1.1ScalarsensorCountread-onlycurrentNumber of sensor managed on this device.
1.3.6.1.4.1.534.6.8.1.1.2TablesensorIdentificationTablenot-accessiblecurrentA list of sensor devices identification data. The number of entries is given by sensorCount.
1.3.6.1.4.1.534.6.8.1.1.2.1RowsensorIdentificationEntrynot-accessiblecurrentAn entry for a sensor device identification.
1.3.6.1.4.1.534.6.8.1.1.2.1.1ColumnsensorIndexaccessible-for-notifycurrentA unique value for each sensor device. Its value ranges from 1 to sensorCount.
1.3.6.1.4.1.534.6.8.1.1.2.1.2ColumnsensorUuidread-onlycurrentA unique uuid value for each sensor device.
1.3.6.1.4.1.534.6.8.1.1.2.1.3ColumnsensorConnectionTyperead-onlycurrentSensor connection type with the device that monitors it.
1.3.6.1.4.1.534.6.8.1.1.2.1.4ColumnsensorAddressread-onlycurrentDepending of the connection implementation : Modbus Slave Id, BT Mac address, ...
1.3.6.1.4.1.534.6.8.1.1.2.1.5ColumnsensorMonitoredByread-onlycurrentParent oid device where the sensor is connected to and monitored by.
1.3.6.1.4.1.534.6.8.1.1.2.1.6ColumnsensorManufacturerread-onlycurrentThe vendor name of the sensor device.
1.3.6.1.4.1.534.6.8.1.1.2.1.7ColumnsensorModelread-onlycurrentThe model name of the sensor device.
1.3.6.1.4.1.534.6.8.1.1.2.1.8ColumnsensorPartNumberread-onlycurrentThe catalog part number of the sensor device.
1.3.6.1.4.1.534.6.8.1.1.2.1.9ColumnsensorSerialNumberread-onlycurrentThe serial number of the sensor device.
1.3.6.1.4.1.534.6.8.1.1.2.1.10ColumnsensorFirmwareVersionread-onlycurrentThe firmware version of the sensor device.
1.3.6.1.4.1.534.6.8.1.1.3TablesensorConfigurationTablenot-accessiblecurrentA list of sensor devices configuration data. The number of entries is given by sensorCount.
1.3.6.1.4.1.534.6.8.1.1.3.1RowsensorConfigurationEntrynot-accessiblecurrentAn entry for a sensor device configuration.
1.3.6.1.4.1.534.6.8.1.1.3.1.1ColumnsensorNameread-writecurrentThe friendly name of the sensor device.
1.3.6.1.4.1.534.6.8.1.1.3.1.2ColumnsensorLocationread-writecurrentThe location of the sensor device.
1.3.6.1.4.1.534.6.8.1.1.3.1.3ColumnsensorPositionread-writecurrentThe Position by reference to the data center aisle.
1.3.6.1.4.1.534.6.8.1.1.3.1.4ColumnsensorElevationread-writecurrentThe Elevation in the rack.
1.3.6.1.4.1.534.6.8.1.1.3.1.5ColumnsensorUElevationread-writecurrentThe elevation in the rack in count of U position from the bottom.
1.3.6.1.4.1.534.6.8.1.1.4TablesensorMonitoringTablenot-accessiblecurrentA list of sensor devices monitoring data. The number of entries is given by sensorCount.
1.3.6.1.4.1.534.6.8.1.1.4.1RowsensorMonitoringEntrynot-accessiblecurrentAn entry for a sensor device monitoring.
1.3.6.1.4.1.534.6.8.1.1.4.1.1ColumnsensorStatusread-onlycurrentIndicates how the sensor is communicating or not.
1.3.6.1.4.1.534.6.8.1.1.4.1.2ColumnsensorStatusSinceread-onlycurrentUTC time in seconds since 1970/01/01 dating the sensor status last change.
1.3.6.1.4.1.534.6.8.1.1.4.1.3ColumnsensorTemperatureCountread-onlycurrentNumber of temperature probes managed by the sensor device.
1.3.6.1.4.1.534.6.8.1.1.4.1.4ColumnsensorHumidityCountread-onlycurrentNumber of humidity probes managed by the sensor device.
1.3.6.1.4.1.534.6.8.1.1.4.1.5ColumnsensorDigitalInputCountread-onlycurrentNumber of digital input probes managed by the sensor device.
1.3.6.1.4.1.534.6.8.1.1.4.1.6ColumnsensorAnalogInputCountread-onlycurrentNumber of analog input probes managed by the sensor device.
1.3.6.1.4.1.534.6.8.1.2Nodetemperature
1.3.6.1.4.1.534.6.8.1.2.0NodetemperatureNotification
1.3.6.1.4.1.534.6.8.1.2.0.1NotificationnotifyTemperatureAlarmcurrentSent whenever the temperature alarm changes.
1.3.6.1.4.1.534.6.8.1.2.0.2NotificationnotifyTemperatureCommunicationStatuscurrentSent whenever the temperature communication status changes. Is not implemented when the probe is internal (see temperatureConnectionType).
1.3.6.1.4.1.534.6.8.1.2.1TabletemperatureIdentificationTablenot-accessiblecurrentA list of temperature probe measurements. the number of entries is given by the temperature count.
1.3.6.1.4.1.534.6.8.1.2.1.1RowtemperatureIdentificationEntrynot-accessiblecurrentAn entry for a temperature probe identification.
1.3.6.1.4.1.534.6.8.1.2.1.1.1ColumntemperatureIndexaccessible-for-notifycurrentA unique value for each temperature probe measurement. Its value ranges from 1 to sensorTemperatureCount.
1.3.6.1.4.1.534.6.8.1.2.1.1.2ColumntemperatureUuidread-onlycurrentA unique uuid value for each temperature.
1.3.6.1.4.1.534.6.8.1.2.1.1.3ColumntemperatureConnectionTyperead-onlycurrentProbe connection type with the sensor that monitors it.
1.3.6.1.4.1.534.6.8.1.2.2TabletemperatureConfigurationTablenot-accessiblecurrentA list of temperature probe configuration. The number of entries is given by sensorTemperatureCount.
1.3.6.1.4.1.534.6.8.1.2.2.1RowtemperatureConfigurationEntrynot-accessiblecurrentAn entry for a temperature probe configuration.
1.3.6.1.4.1.534.6.8.1.2.2.1.1ColumntemperatureNameread-writecurrentThe friendly name of the sensor temperature probe.
1.3.6.1.4.1.534.6.8.1.2.2.1.2ColumntemperatureEnableread-writecurrentConfigure the temperature acquired or not. 0:disabled, 1:enabled
1.3.6.1.4.1.534.6.8.1.2.2.1.3ColumntemperatureOffsetread-writecurrentConfigure the offset (Minus or Plus) to be added to the acquired value in order to correct the probe measurement error. See temperatureUnit data for the units.
1.3.6.1.4.1.534.6.8.1.2.2.1.4ColumntemperatureAlarmEnableread-writecurrentConfigure the temperature alarm depending on the thresholds evaluated or not. 0:disabled, 1:enabled
1.3.6.1.4.1.534.6.8.1.2.2.1.5ColumntemperatureThresholdLowWarningread-writecurrentLow warning temperature threshold. See temperatureUnit data for the units.
1.3.6.1.4.1.534.6.8.1.2.2.1.6ColumntemperatureThresholdLowCriticalread-writecurrentLow critical temperature threshold. See temperatureUnit data for the units.
1.3.6.1.4.1.534.6.8.1.2.2.1.7ColumntemperatureThresholdHighWarningread-writecurrentHigh warning temperature threshold. See temperatureUnit data for the units.
1.3.6.1.4.1.534.6.8.1.2.2.1.8ColumntemperatureThresholdHighCriticalread-writecurrentHigh critical temperature threshold. See temperatureUnit data for the units.
1.3.6.1.4.1.534.6.8.1.2.2.1.9ColumntemperatureThresholdHysteresisread-writecurrentTemperature threshold hysteresis. See temperatureUnit data for the units.
1.3.6.1.4.1.534.6.8.1.2.2.1.10ColumntemperatureAlarmGracePeriodread-writecurrentThe grace period the alarm triggers after the acquired value crosses a trigger value (in seconds).
1.3.6.1.4.1.534.6.8.1.2.3TabletemperatureMonitoringTablenot-accessiblecurrentA list of temperature probe monitoring. The number of entries is given by sensorTemperatureCount.
1.3.6.1.4.1.534.6.8.1.2.3.1RowtemperatureMonitoringEntrynot-accessiblecurrentAn entry for a temperature probe monitoring.
1.3.6.1.4.1.534.6.8.1.2.3.1.1ColumntemperatureAlarmread-onlycurrentAlarm set according to the realtime measure compared to the thresholds.
1.3.6.1.4.1.534.6.8.1.2.3.1.2ColumntemperatureAlarmChangeSinceread-onlycurrentUTC time in seconds since 1970/01/01 dating the temperature alarm last change.
1.3.6.1.4.1.534.6.8.1.2.3.1.3ColumntemperatureValueread-onlycurrentRealtime measured value after correction with the offset. See temperatureUnit data for the units.
1.3.6.1.4.1.534.6.8.1.2.3.1.4ColumntemperatureCommunicationStatusread-onlycurrentIndicates how the temperature probe is communicating or not.
1.3.6.1.4.1.534.6.8.1.2.3.1.5ColumntemperatureCommunicationStatusSinceread-onlycurrentUTC time in seconds since 1970/01/01 dating the temperature communication status last change.
1.3.6.1.4.1.534.6.8.1.2.4TabletemperatureMonitoringMinMaxTablenot-accessiblecurrentA list of temperature probe monitoring Min and Max. The number of entries is given by sensorTemperatureCount.
1.3.6.1.4.1.534.6.8.1.2.4.1RowtemperatureMonitoringMinMaxEntrynot-accessiblecurrentAn entry for a temperature probe monitoring Min and Max.
1.3.6.1.4.1.534.6.8.1.2.4.1.1ColumntemperatureMinValueread-onlycurrentMinimum value registered since the 1st connection of the sensor or the last reset. See temperatureUnit data for the units.
1.3.6.1.4.1.534.6.8.1.2.4.1.2ColumntemperatureMinValueSinceread-onlycurrentUTC time in seconds since 1970/01/01 dating the temperature min value last change.
1.3.6.1.4.1.534.6.8.1.2.4.1.3ColumntemperatureMaxValueread-onlycurrentMaximum value registered since the 1st connection of the sensor or the last reset. See temperatureUnit data for the units.
1.3.6.1.4.1.534.6.8.1.2.4.1.4ColumntemperatureMaxValueSinceread-onlycurrentUTC time in seconds since 1970/01/01 dating the temperature max value last change.
1.3.6.1.4.1.534.6.8.1.2.4.1.5ColumntemperatureResetMinMaxread-writecurrentCommand that resets the min and max data with the current measure. 0:None, 1:Reset
1.3.6.1.4.1.534.6.8.1.2.5ScalartemperatureUnitread-writecurrentTemperature unit configuration. It is a global setting for all the v1 and v3 SNMP client. It does not involve the temperature unit of data stored and managed i…
1.3.6.1.4.1.534.6.8.1.3Nodehumidity
1.3.6.1.4.1.534.6.8.1.3.0NodehumidityNotification
1.3.6.1.4.1.534.6.8.1.3.0.1NotificationnotifyHumidityAlarmcurrentSent whenever the humidity alarm changes.
1.3.6.1.4.1.534.6.8.1.3.0.2NotificationnotifyHumidityCommunicationStatuscurrentSent whenever the humidity communication status changes. Is not implemented when the probe is internal (see humidityConnectionType).
1.3.6.1.4.1.534.6.8.1.3.1TablehumidityIdentificationTablenot-accessiblecurrentA list of humidity probe measurements. the number of entries is given by the humidity count.
1.3.6.1.4.1.534.6.8.1.3.1.1RowhumidityIdentificationEntrynot-accessiblecurrentAn entry for a humidity probe identification.
1.3.6.1.4.1.534.6.8.1.3.1.1.1ColumnhumidityIndexaccessible-for-notifycurrentA unique value for each humidity probe measurement. Its value ranges from 1 to sensorhumidityCount.
1.3.6.1.4.1.534.6.8.1.3.1.1.2ColumnhumidityUuidread-onlycurrentA unique uuid value for each humidity.
1.3.6.1.4.1.534.6.8.1.3.1.1.3ColumnhumidityConnectionTyperead-onlycurrentProbe connection type with the sensor that monitors it.
1.3.6.1.4.1.534.6.8.1.3.2TablehumidityConfigurationTablenot-accessiblecurrentA list of humidity probe configuration. The number of entries is given by sensorhumidityCount.
1.3.6.1.4.1.534.6.8.1.3.2.1RowhumidityConfigurationEntrynot-accessiblecurrentAn entry for a humidity probe configuration.
1.3.6.1.4.1.534.6.8.1.3.2.1.1ColumnhumidityNameread-writecurrentThe friendly name of the sensor humidity probe.
1.3.6.1.4.1.534.6.8.1.3.2.1.2ColumnhumidityEnableread-writecurrentConfigure the humidity acquired or not. 0:disabled, 1:enabled
1.3.6.1.4.1.534.6.8.1.3.2.1.3ColumnhumidityOffsetread-writecurrentConfigure the offset (Minus or Plus) to be added to the acquired value in order to correct the probe measurement error. in tenth of % units.
1.3.6.1.4.1.534.6.8.1.3.2.1.4ColumnhumidityAlarmEnableread-writecurrentConfigure the humidity alarm depending on the thresholds evaluated or not. 0:disabled, 1:enabled
1.3.6.1.4.1.534.6.8.1.3.2.1.5ColumnhumidityThresholdLowWarningread-writecurrentLow warning humidity threshold in tenth of % units.
1.3.6.1.4.1.534.6.8.1.3.2.1.6ColumnhumidityThresholdLowCriticalread-writecurrentLow critical humidity threshold in tenth of % units.
1.3.6.1.4.1.534.6.8.1.3.2.1.7ColumnhumidityThresholdHighWarningread-writecurrentHigh warning humidity threshold in tenth of % units.
1.3.6.1.4.1.534.6.8.1.3.2.1.8ColumnhumidityThresholdHighCriticalread-writecurrentHigh critical humidity threshold in tenth of % units.
1.3.6.1.4.1.534.6.8.1.3.2.1.9ColumnhumidityThresholdHysteresisread-writecurrenthumidity threshold hysteresis in tenth of % units.
1.3.6.1.4.1.534.6.8.1.3.2.1.10ColumnhumidityAlarmGracePeriodread-writecurrentThe grace period the alarm triggers after the acquired value crosses a trigger value (in seconds).
1.3.6.1.4.1.534.6.8.1.3.3TablehumidityMonitoringTablenot-accessiblecurrentA list of humidity probe monitoring. The number of entries is given by sensorhumidityCount.
1.3.6.1.4.1.534.6.8.1.3.3.1RowhumidityMonitoringEntrynot-accessiblecurrentAn entry for a humidity probe monitoring.
1.3.6.1.4.1.534.6.8.1.3.3.1.1ColumnhumidityAlarmread-onlycurrentAlarm set according to the realtime measure compared to the thresholds.
1.3.6.1.4.1.534.6.8.1.3.3.1.2ColumnhumidityAlarmChangeSinceread-onlycurrentUTC time in seconds since 1970/01/01 dating the humidity alarm last change.
1.3.6.1.4.1.534.6.8.1.3.3.1.3ColumnhumidityValueread-onlycurrentRealtime measured value after correction with the offset. in tenth of % units.
1.3.6.1.4.1.534.6.8.1.3.3.1.4ColumnhumidityCommunicationStatusread-onlycurrentIndicates how the humidity probe is communicating or not.
1.3.6.1.4.1.534.6.8.1.3.3.1.5ColumnhumidityCommunicationStatusSinceread-onlycurrentUTC time in seconds since 1970/01/01 dating the humidity communication status last change.
1.3.6.1.4.1.534.6.8.1.3.4TablehumidityMonitoringMinMaxTablenot-accessiblecurrentA list of humidity probe monitoring Min and Max. The number of entries is given by sensorhumidityCount.
1.3.6.1.4.1.534.6.8.1.3.4.1RowhumidityMonitoringMinMaxEntrynot-accessiblecurrentAn entry for a humidity probe monitoring Min and Max.
1.3.6.1.4.1.534.6.8.1.3.4.1.1ColumnhumidityMinValueread-onlycurrentMinimum value registered since the 1st connection of the sensor or the last reset. in tenth of % units.
1.3.6.1.4.1.534.6.8.1.3.4.1.2ColumnhumidityMinValueSinceread-onlycurrentUTC time in seconds since 1970/01/01 dating the humidity min value last change.
1.3.6.1.4.1.534.6.8.1.3.4.1.3ColumnhumidityMaxValueread-onlycurrentMaximum value registered since the 1st connection of the sensor or the last reset. in tenth of % units.
1.3.6.1.4.1.534.6.8.1.3.4.1.4ColumnhumidityMaxValueSinceread-onlycurrentUTC time in seconds since 1970/01/01 dating the humidity max value last change.
1.3.6.1.4.1.534.6.8.1.3.4.1.5ColumnhumidityResetMinMaxread-writecurrentCommand that resets the min and max data with the current measure. 0:None, 1:Reset
1.3.6.1.4.1.534.6.8.1.4NodedigitalInput
1.3.6.1.4.1.534.6.8.1.4.0NodedigitalInputNotification
1.3.6.1.4.1.534.6.8.1.4.0.1NotificationnotifyDigitalInputAlarmcurrentSent whenever the digital input alarm changes.
1.3.6.1.4.1.534.6.8.1.4.0.2NotificationnotifydigitalInputCommunicationStatuscurrentSent whenever the digital input communication status changes. Is not implemented when the probe is internal (see digitalInputConnectionType).
1.3.6.1.4.1.534.6.8.1.4.1TabledigitalInputIdentificationTablenot-accessiblecurrentA list of digital input probe measurements. The number of entries is given by sensorDigitalInputCount.
1.3.6.1.4.1.534.6.8.1.4.1.1RowdigitalInputIdentificationEntrynot-accessiblecurrentAn entry for a digital input identification.
1.3.6.1.4.1.534.6.8.1.4.1.1.1ColumndigitalInputIndexaccessible-for-notifycurrentA unique value for each digital input probe measurement. Its value ranges from 1 to sensorDigitalInputCount.
1.3.6.1.4.1.534.6.8.1.4.1.1.2ColumndigitalInputUuidread-onlycurrentA unique uuid value for each digital Input.
1.3.6.1.4.1.534.6.8.1.4.1.1.3ColumndigitalInputConnectionTyperead-onlycurrentProbe connection type with the sensor that monitors it.
1.3.6.1.4.1.534.6.8.1.4.2TabledigitalInputConfigurationTablenot-accessiblecurrentA list of digital input probe configuration. The number of entries is given by sensorDigitalInputCount.
1.3.6.1.4.1.534.6.8.1.4.2.1RowdigitalInputConfigurationEntrynot-accessiblecurrentAn entry for a digital input probe configuration.
1.3.6.1.4.1.534.6.8.1.4.2.1.1ColumndigitalInputNameread-writecurrentThe friendly name of the digital input probe.
1.3.6.1.4.1.534.6.8.1.4.2.1.2ColumndigitalInputEnableread-writecurrentConfigure the digital input acquired or not. 0:disabled, 1:enabled
1.3.6.1.4.1.534.6.8.1.4.2.1.3ColumndigitalInputPolarityread-writecurrentConfigure the digitalInput polarity. 0 : Normally opened, 1 : Normally closed
1.3.6.1.4.1.534.6.8.1.4.2.1.4ColumndigitalInputAlarmEnableread-writecurrentConfigure the digitalInput alarm depending on the polarity evaluated or not. 0:disabled, 1:enabled
1.3.6.1.4.1.534.6.8.1.4.2.1.5ColumndigitalInputAlarmSeverityread-writecurrentConfigure the alarm severity.
1.3.6.1.4.1.534.6.8.1.4.2.1.6ColumndigitalInputAlarmGracePeriodread-writecurrentThe delay the alarm triggers when the state change event occurs (in seconds).
1.3.6.1.4.1.534.6.8.1.4.3TabledigitalInputMonitoringTablenot-accessiblecurrentA list of digital input probee monitoring. The number of entries is given by sensorDigitalInputCount.
1.3.6.1.4.1.534.6.8.1.4.3.1RowdigitalInputMonitoringEntrynot-accessiblecurrentAn entry for a digital Input probe.
1.3.6.1.4.1.534.6.8.1.4.3.1.1ColumndigitalInputAlarmread-onlycurrentAlarm set according to the polarity and alarm severity configuration.
1.3.6.1.4.1.534.6.8.1.4.3.1.2ColumndigitalInputAlarmChangeSinceread-onlycurrentUTC time in seconds since 1970/01/01 dating the digital input alarm last change.
1.3.6.1.4.1.534.6.8.1.4.3.1.3ColumndigitalInputStateread-onlycurrentMeasure of the digital input after applying the polarity configured. 0 : Inactive, 1 : Active
1.3.6.1.4.1.534.6.8.1.4.3.1.4ColumndigitalInputStateSinceread-onlycurrentUTC time in seconds since 1970/01/01 dating the digital input state last change.
1.3.6.1.4.1.534.6.8.1.4.3.1.5ColumndigitalInputCommunicationStatusread-onlycurrentIndicates how the digital input is communicating or not.
1.3.6.1.4.1.534.6.8.1.4.3.1.6ColumndigitalInputCommunicationStatusSinceread-onlycurrentUTC time in seconds since 1970/01/01 dating the digital input communication status last change.
1.3.6.1.4.1.534.6.8.1.10Nodeconformance
1.3.6.1.4.1.534.6.8.1.10.1ComplianceeatonSensorCompliancescurrentThe requirements for conforming to the Sensor MIB.
1.3.6.1.4.1.534.6.8.1.10.2NodeobjectGroups
1.3.6.1.4.1.534.6.8.1.10.2.1GroupsensorRequiredGroupcurrentThese objects are required to conform to this MIB.
1.3.6.1.4.1.534.6.8.1.10.2.2GroupsensorOptionalGroupcurrentThese objects in this MIB are optional.
1.3.6.1.4.1.534.6.8.1.10.2.3GroupsensorNotifyGroupcurrentThese notifications will be supported depending on the features of the sensor.
Type Definitions
NameSyntaxStatusDescription
AlarmLevelTypeINTEGER { good(0), informational(1), warning(2), critical(3) }currentDescribes the alarm level.
AlarmSeverityTypeINTEGER { informational(1), warning(2), critical(3) }currentDescribes the alarm severity.
AlarmTypeINTEGER { good(0), lowWarning(1), lowCritical(2), highWarning(3), highCritical(4) }currentDescribes the alarm according to a measured value by reference to the triggers.
CommunicationStatusINTEGER { unknown(0), communicationOK(2), communicationLost(3) }currentDescribes the communication sensor status or probe status.
ElevationTypeINTEGER { undefined(0), other(1), bottom(2), middle(3), top(4) }currentDescribes the elevation in the rack.
EnableTypeINTEGER { disabled(0), enabled(1) }currentDescribes enable/disable.
PolarityTypeINTEGER { normallyOpened(0), normallyClosed(1) }currentDescribes the polarity configuration.
PositionTypeINTEGER { undefined(0), other(1), rackRear(2), rackFront(3), batteryRoom(4) }currentDescribes the position by reference to the data center aisle.
ProbeConnectionTypeINTEGER { undefined(0), internal(1), wired(2), wireless(3) }currentDescribes the probe connection to the sensor or probe.
ResetCommandTypeINTEGER { none(0), reset(1) }currentCommands a reset.
StateTypeINTEGER { inactive(0), active(1) }currentDescribes the state of a digital input that depends on its measure and the polrity configuration.
TemperatureUnitTypeINTEGER { tenthOfDegKelvin(0), tenthOfDegCelsius(1), tenthOfDegFarhenheit(2) }currentDescribes the temperature unit used to read/write the temperature data.
UnixTimeStampCounter32currentUnix time stamp. Measured in seconds since January 1, 1970.