MIB Viewer

EKINOPS-MGNT2-MIB

351 objects
MIB for Ekinops 360 management.
OIDNameAccessStatusDescription
1.3.6.1.4.1.20044.7Identitymgnt2MIB for Ekinops 360 management.
1.3.6.1.4.1.20044.7.1Nodemgnt2SNMPAgentData
1.3.6.1.4.1.20044.7.1.1Nodemgnt2IPmanagment
1.3.6.1.4.1.20044.7.1.1.1Tablemgnt2GigmManagerIpAddressTablenot-accessiblecurrentManager IP address Table.
1.3.6.1.4.1.20044.7.1.1.1.1Rowmgnt2GigmManagerIpAddressEntrynot-accessiblecurrent
1.3.6.1.4.1.20044.7.1.1.1.1.1Columnmgnt2GigmManagerIpIndexread-createcurrentIndex of the IP address of the manager
1.3.6.1.4.1.20044.7.1.1.1.1.2Columnmgnt2GigmManagerIpAddressread-createcurrentIP address of the manager:This OID defines the IP address of the SNMP Manager attached to the Mgnt2
1.3.6.1.4.1.20044.7.1.1.1.1.3Columnmgnt2GigmManagerIpAddressTableRowStatusread-createcurrentThe status of this row.
1.3.6.1.4.1.20044.7.1.1.1.1.4Columnmgnt2GigmManagerTrapPortread-createcurrentManager UDP port.
1.3.6.1.4.1.20044.7.1.1.1.1.5Columnmgnt2GigmManagerEnableCtrlread-createcurrentEnabling trap of Ctrl.
1.3.6.1.4.1.20044.7.1.1.1.1.6Columnmgnt2GigmManagerEnableConfigread-createcurrentEnabling trap of config.
1.3.6.1.4.1.20044.7.1.1.1.1.7Columnmgnt2GigmManagerEnableEventread-createcurrentEnabling trap of event.
1.3.6.1.4.1.20044.7.1.1.1.1.8Columnmgnt2GigmManagerEnableAlarmCritread-createcurrentEnabling trap of crit alarm.
1.3.6.1.4.1.20044.7.1.1.1.1.9Columnmgnt2GigmManagerEnableAlarmMajorread-createcurrentEnabling trap of major alarm.
1.3.6.1.4.1.20044.7.1.1.1.1.10Columnmgnt2GigmManagerEnableAlarmMinorread-createcurrentEnabling trap of minor alarm.
1.3.6.1.4.1.20044.7.1.1.1.1.11Columnmgnt2GigmManagerRegistrationTimeoutread-createcurrentTime-out for manager activities.
1.3.6.1.4.1.20044.7.1.1.1.1.12Columnmgnt2GigmManagerEnableAlarmWarningread-createcurrentEnabling trap of warning alarm.
1.3.6.1.4.1.20044.7.1.1.1.1.13Columnmgnt2GigmManagerEnableAlarmIndeterminateread-createcurrentEnabling trap of indeterminate alarm.
1.3.6.1.4.1.20044.7.1.1.2Scalarmgnt2GigmBoardIpAddressread-writecurrentIP address of the Chassis:This OID defines the IP address of the Mgnt2
1.3.6.1.4.1.20044.7.1.1.3Scalarmgnt2GigmIPAddresByDHCPread-writecurrentIP address retrieved by DHCP:If enabled, the IP address is retrieved by DHCP, in which case changes take effect after a board reset. If disabled the object, mg…
1.3.6.1.4.1.20044.7.1.1.4Scalarmgnt2GigmNetmaskread-writecurrentNetmask for the board IP address:This OID defined the IP Subnet mask of the Mgnt2
1.3.6.1.4.1.20044.7.1.1.5Tablemgnt2GigmGatewayAddressTablenot-accessiblecurrentGateway IP address Table: This table contains all the gateway IP addresses.
1.3.6.1.4.1.20044.7.1.1.5.1Rowmgnt2GigmGatewayAddressEntrynot-accessiblecurrent
1.3.6.1.4.1.20044.7.1.1.5.1.1Columnmgnt2GigmGatewayIndexread-createcurrentIndex of the IP address of the gateway
1.3.6.1.4.1.20044.7.1.1.5.1.2Columnmgnt2GigmGatewayAddressread-createcurrentIP address of the gateway :This OID defines the IP address of the gateway attached to the Chassis
1.3.6.1.4.1.20044.7.1.1.5.1.3Columnmgnt2GigmGatewayOrderread-createcurrentGateway priority: This OID defines the priority of the gateway (lower number for higher priority)
1.3.6.1.4.1.20044.7.1.1.6Scalarmgnt2GigmSyslogread-writecurrentIP address of the syslog server:This OID defines the IP address of the syslog of the Mgnt2
1.3.6.1.4.1.20044.7.1.1.7Scalarmgnt2GigmNtpServerread-writecurrentIP address of the ntp server:This OID defines the IP address of the ntp server for the Mgnt2
1.3.6.1.4.1.20044.7.1.1.8Scalarmgnt2GigmNodeIpAddressread-writecurrentNode IP address :This OID defines the Node IP address in node controller mode for the Mgnt2
1.3.6.1.4.1.20044.7.1.2Nodemgnt2ModulesManagement
1.3.6.1.4.1.20044.7.1.2.1Tablemgnt2GigmBoardTablenot-accessiblecurrentList of PMs plugged in the Chassis
1.3.6.1.4.1.20044.7.1.2.1.1Rowmgnt2GigmBoardEntrynot-accessiblecurrentRow Definition for the PMs table
1.3.6.1.4.1.20044.7.1.2.1.1.1Columnmgnt2IndexBoardsread-onlycurrentIndex for PMs table
1.3.6.1.4.1.20044.7.1.2.1.1.2Columnmgnt2Positionread-onlycurrentPM Slot number:This OID gives the slot number in which the PM is plugged
1.3.6.1.4.1.20044.7.1.2.1.1.3Columnmgnt2Nameread-onlycurrentPM name:This OID gives the name of the PM plugged in the Mgnt2
1.3.6.1.4.1.20044.7.1.2.1.1.4Columnmgnt2PortNumberread-onlycurrentNumber of Client Ports:This OID gives the number of client ports on the PM plugged in the Mgnt2
1.3.6.1.4.1.20044.7.1.2.1.1.5Columnmgnt2LineNumberread-onlycurrentNumber of Line Ports:This OID gives the number of line ports on the PM plugged in the Mgnt2
1.3.6.1.4.1.20044.7.1.2.1.1.6Columnmgnt2GroupNumberread-onlycurrentNumber of Groups:This OID gives the number of group of clients on the PM plugged in the Mgnt2
1.3.6.1.4.1.20044.7.1.2.1.1.7Columnmgnt2RootOIDInventoryread-onlycurrentroot oid of the inventory leaf of the corresponding PM
1.3.6.1.4.1.20044.7.1.2.1.1.8Columnmgnt2SlotOccread-onlycurrentPM Slot occupied:This OID gives the slots taken by this PM
1.3.6.1.4.1.20044.7.1.2.1.1.9Columnmgnt2SubFunctionLabelread-onlycurrentSub Function Label: This OID gives the name of the sub function embedded on the Chassis. (applied only on the 100G Chassis)
1.3.6.1.4.1.20044.7.1.2.1.1.10Columnmgnt2SlotStatusread-onlycurrentSlot Status: This OID gives the status of the slot in the Chassis: See Textual COnvention
1.3.6.1.4.1.20044.7.1.2.7Scalarmgnt2GigmSelectedBoardread-writecurrentPM Slot number selected:PM selected for further operations in the Ekinops module board tree. This number is the slot number.
1.3.6.1.4.1.20044.7.1.4Tablemgnt2GigmMibsTablenot-accessibleobsoleteList of MIBs supported by the Chassis SNMPAgent
1.3.6.1.4.1.20044.7.1.4.1Rowmgnt2GigmMibsEntrynot-accessibleobsoleteRow definition for MIBs table
1.3.6.1.4.1.20044.7.1.4.1.1Columnmgnt2IndexMibsread-onlyobsoleteIndex for MIBs table
1.3.6.1.4.1.20044.7.1.4.1.2Columnmgnt2MibNameread-onlyobsoleteMIB name:This OID gives the name of the MIBs supported by the SNMP Agent
1.3.6.1.4.1.20044.7.1.4.1.3Columnmgnt2MibPartNumberread-onlyobsoleteMIB Part Number:This OID gives the part number of the MIBs supported by the SNMP Agent
1.3.6.1.4.1.20044.7.1.5Scalarmgnt2GigmLogicalNameread-writecurrentMgnt2 name:This OID defines the name of the Mgnt2
1.3.6.1.4.1.20044.7.1.6Scalarmgnt2GigmEqptTyperead-onlycurrentEquipment type:This OID defines the type of the Equipment
1.3.6.1.4.1.20044.7.1.7Nodemgnt2GigmTrapCount
1.3.6.1.4.1.20044.7.1.7.1Scalarmgnt2GigmTrapCounterread-onlycurrentTrap counter:This OID counts the number of trap sent
1.3.6.1.4.1.20044.7.1.7.2Scalarmgnt2GigmResetTrapCounterread-writecurrentReset trap counter:This OID reset the trap counter to 0
1.3.6.1.4.1.20044.7.1.8Nodemgnt2GigmSecurity
1.3.6.1.4.1.20044.7.1.8.1Scalarmgnt2GigmRoCommunityread-writecurrentSNMP Get community:This OID defines the community for the SNMP Get function
1.3.6.1.4.1.20044.7.1.8.2Scalarmgnt2GigmRwCommunityread-writecurrentSNMP Set community:This OID defines the community for the SNMP Set function
1.3.6.1.4.1.20044.7.1.8.3Scalarmgnt2GigmTrapCommunityread-writecurrentSNMP Trap community:This OID defines the community for the SNMP Trap function
1.3.6.1.4.1.20044.7.1.9Nodemgnt2GigmTime
1.3.6.1.4.1.20044.7.1.9.1Scalarmgnt2GigmCurrentHourread-writecurrentChassis Hour time:This OID defines the hour of the chassis' time
1.3.6.1.4.1.20044.7.1.9.2Scalarmgnt2GigmCurrentMinuteread-writecurrentChassis Minute time:This OID defines the minute of the chassis' time
1.3.6.1.4.1.20044.7.1.9.3Scalarmgnt2GigmCurrentYearread-writecurrentChassis year date:This OID defines the year of the chassis' date
1.3.6.1.4.1.20044.7.1.9.4Scalarmgnt2GigmCurrentMonthread-writecurrentChassis month date:This OID defines the month of the chassis' date
1.3.6.1.4.1.20044.7.1.9.5Scalarmgnt2GigmCurrentDayread-writecurrentChassis day date:This OID defines the day of the chassis' date
1.3.6.1.4.1.20044.7.1.10Nodemgnt2Authentication
1.3.6.1.4.1.20044.7.1.10.1Scalarmgnt2GigmRadiusServerread-writecurrentIP address of the RADIUS server:This OID defines the IP address of the external RADIUS server for authentication
1.3.6.1.4.1.20044.7.1.10.2Scalarmgnt2GigmRadiusPortread-writecurrentTCP port number of the RADIUS server:This OID defines the TCP port number of the external RADIUS server for authentication
1.3.6.1.4.1.20044.7.1.10.3Scalarmgnt2GigmRadiusSecretread-writecurrentShared secret of the RADIUS server:This OID defines the shared secret password of the RADIUS server for authentication
1.3.6.1.4.1.20044.7.1.10.4Scalarmgnt2GigmLdapHostread-writedeprecatedIP address of the LDAP host:This OID defines the IP address of the external LDAP server for authentication
1.3.6.1.4.1.20044.7.1.10.5Scalarmgnt2GigmLdapPortread-writedeprecatedTCP port number of the LDAP server:This OID defines the TCP port number of the external LDAP server for authentication
1.3.6.1.4.1.20044.7.1.10.6Scalarmgnt2GigmLdapBaseread-writedeprecatedLDAP base:This OID defines the name of the search base of the LDAP server for authentication<Help>LDAP base name spelled as follows: 'ou=users,ou=network,dc=yo…
1.3.6.1.4.1.20044.7.1.10.7Scalarmgnt2GigmLdapVersionread-writedeprecatedProtocol number in use by the LDAP server:This OID defines the protocol version used by the external LDAP server for authentication<Help>Protocol version used …
1.3.6.1.4.1.20044.7.1.10.8Scalarmgnt2GigmLdapBindDnread-writedeprecatedLDAP Bind DN:This OID defines the login name used to connect into the LDAP server base for authentication<Help>LDAP binddn spelled as follows: 'cn=ldap_admin,d…
1.3.6.1.4.1.20044.7.1.10.9Scalarmgnt2GigmLdapBindPwread-writedeprecatedCredentials to bind the LDAP server with:This OID defines the credentials to bind the LDAP server with for authentication<Help>Credentials for LDAP access (bin…
1.3.6.1.4.1.20044.7.1.10.10Scalarmgnt2GigmLdapScoperead-writedeprecatedScope for LDAP base search:This OID defines the search scope for an LDAP base search <Help>LDAP search scope
1.3.6.1.4.1.20044.7.1.10.11Scalarmgnt2GigmLdapPamPasswdread-writedeprecatedPAM password handling:This OID defines the way the PAM password is handled for LDAP authentication <Help>The 'pam_password' option sould be one of the followin…
1.3.6.1.4.1.20044.7.1.10.12Scalarmgnt2GigmAuthenticationTyperead-writecurrentAuthentication type in use
1.3.6.1.4.1.20044.7.2Nodemgnt2Hardware
1.3.6.1.4.1.20044.7.2.1Nodemgnt2alarms
1.3.6.1.4.1.20044.7.2.1.0Nodemgnt2AlmsynthAlm0
1.3.6.1.4.1.20044.7.2.1.0.9Scalarmgnt2AlmAbsFailureread-onlycurrentChassis Management Module Failure :This OID indicates that the Chassis Management module is in fail condition <Condtype> ABS_FAILURE <Probcause> other(1) <Alar…
1.3.6.1.4.1.20044.7.2.1.0.10Scalarmgnt2AlmFansFailureread-onlycurrentChassis Fan Module Failure :This OID indicates that at least one of the three FAN unit of the FAN module is in fail condition <Condtype> FANS_FAILURE <Probcaus…
1.3.6.1.4.1.20044.7.2.1.0.11Scalarmgnt2AlmDef48aread-onlycurrentPower Input A Present :This OID indicates that there is not input power on the right power connector (A) <Help> This alarm indicates if the power input B is pr…
1.3.6.1.4.1.20044.7.2.1.0.12Scalarmgnt2AlmDef48bread-onlycurrentPower Input B Present :This OID indicates that there is not input power on the right power connector (B) <Help> This alarm indicates if the power input B is pr…
1.3.6.1.4.1.20044.7.2.1.0.15Scalarmgnt2AlmMgntDefFuseAread-onlycurrentMgnt Fuse A Fail :This OID indicates that the fuse of the power input A is in fail condition on the Management board <Help> Status of the MGNT Fuse A <Condtype…
1.3.6.1.4.1.20044.7.2.1.0.16Scalarmgnt2AlmMgntDefFuseBread-onlycurrentMgnt Fuse B Fail :This OID indicates that the fuse of the power input B is in fail condition on the Management board <Help> Status of the MGNT Fuse B <Condtype…
1.3.6.1.4.1.20044.7.2.1.1Nodemgnt2AlmsynthAlm1
1.3.6.1.4.1.20044.7.2.1.1.1Scalarmgnt2AlmNurgVisualread-onlycurrentMinor Chassis Alarm :This OID indicates at least one Minor alarm is active on the complete chassis (including TR-FAN, MGNT and PM) <Help> This alarm indicates …
1.3.6.1.4.1.20044.7.2.1.1.2Scalarmgnt2AlmUrgVisualread-onlycurrentMajor Chassis Alarm :This OID indicates at least one Major alarm is active on the complete chassis (including TR-FAN, MGNT and PM) <Help> This alarm indicates …
1.3.6.1.4.1.20044.7.2.1.1.3Scalarmgnt2AlmCritVisualread-onlycurrentCritical Chassis Alarm :This OID indicates at least one Critical alarm is active on the complete chassis (including TR-FAN, MGNT and PM) <Help> This alarm indi…
1.3.6.1.4.1.20044.7.2.1.1.16Scalarmgnt2AlmAcknowledgeread-onlycurrentAlarm Ack. :This OID indicates the alarms have been acknowledged by the user (locally or remotely) <Help> This status indicates the alarms have been acknowledg…
1.3.6.1.4.1.20044.7.2.1.16Nodemgnt2AlmboardMgmntSet1
1.3.6.1.4.1.20044.7.2.1.16.2Scalarmgnt2AlmPmSlot1Absentread-onlycurrentPM present in Chassis slot 1 :This OID indicates the presence of a PM in Slot 1 of the Chassis . <Help> This status indicates if a PM is detected in slot 1 <Co…
1.3.6.1.4.1.20044.7.2.1.16.3Scalarmgnt2AlmPmSlot2Absentread-onlycurrentPM present in Chassis slot 2 :This OID indicates the presence of a PM in Slot 2 of the Chassis . <Help> This status indicates if a PM is detected in slot 2 <Co…
1.3.6.1.4.1.20044.7.2.1.16.4Scalarmgnt2AlmPmSlot3Absentread-onlycurrentPM present in Chassis slot 3 :This OID indicates the presence of a PM in Slot 3 of the Chassis . <Help> This status indicates if a PM is detected in slot 3 <Co…
1.3.6.1.4.1.20044.7.2.1.16.5Scalarmgnt2AlmPmSlot4Absentread-onlycurrentPM present in Chassis slot 4 :This OID indicates the presence of a PM in Slot 4 of the Chassis . <Help> This status indicates if a PM is detected in slot 4 <Co…
1.3.6.1.4.1.20044.7.2.1.16.6Scalarmgnt2AlmPmSlot5Absentread-onlycurrentPM present in Chassis slot 5 :This OID indicates the presence of a PM in Slot 5 of the Chassis . <Help> This status indicates if a PM is detected in slot 5 <Co…
1.3.6.1.4.1.20044.7.2.1.16.7Scalarmgnt2AlmPmSlot6Absentread-onlycurrentPM present in Chassis slot 6 :This OID indicates the presence of a PM in Slot 6 of the Chassis . <Help> This status indicates if a PM is detected in slot 6 <Co…
1.3.6.1.4.1.20044.7.2.1.16.8Scalarmgnt2AlmPmSlot7Absentread-onlycurrentPM present in Chassis slot 7 :This OID indicates the presence of a PM in Slot 7 of the Chassis . <Help> This status indicates if a PM is detected in slot 7 <Co…
1.3.6.1.4.1.20044.7.2.1.16.9Scalarmgnt2AlmPmSlot8Absentread-onlycurrentPM present in Chassis slot 8 :This OID indicates the presence of a PM in Slot 8 of the Chassis . <Help> This status indicates if a PM is detected in slot 8 <Co…
1.3.6.1.4.1.20044.7.2.1.16.10Scalarmgnt2AlmPmSlot9Absentread-onlycurrentPM present in Chassis slot 9 :This OID indicates the presence of a PM in Slot 9 of the Chassis . <Help> This status indicates if a PM is detected in slot 9 <Co…
1.3.6.1.4.1.20044.7.2.1.16.11Scalarmgnt2AlmPmSlot10Absentread-onlycurrentPM present in Chassis slot 10 :This OID indicates the presence of a PM in Slot 10 of the Chassis . <Help> This status indicates if a PM is detected in slot 10 …
1.3.6.1.4.1.20044.7.2.1.16.12Scalarmgnt2AlmPmSlot11Absentread-onlycurrentPM present in Chassis slot 11 :This OID indicates the presence of a PM in Slot 11 of the Chassis . <Help> This status indicates if a PM is detected in slot 11 …
1.3.6.1.4.1.20044.7.2.1.16.14Scalarmgnt2AlmPmFanAbsentread-onlycurrentFAN module present in Chassis :This OID indicates the presence of the FAN module in the Chassis. <Help> This alarm indicates if the FAN module is detected in t…
1.3.6.1.4.1.20044.7.2.1.17Nodemgnt2AlmboardMgmntSet2
1.3.6.1.4.1.20044.7.2.1.17.1Scalarmgnt2AlmPmSlot12Absentread-onlycurrentPM present in Chassis slot 12 :This OID indicates the presence of a PM in Slot 12 of the Chassis . <Help> This status indicates if a PM is detected in slot 12 …
1.3.6.1.4.1.20044.7.2.1.17.2Scalarmgnt2AlmPmSlot13Absentread-onlycurrentPM present in Chassis slot 13 :This OID indicates the presence of a PM in Slot 13 of the Chassis . <Help> This status indicates if a PM is detected in slot 13 …
1.3.6.1.4.1.20044.7.2.1.17.3Scalarmgnt2AlmPmSlot14Absentread-onlycurrentPM present in Chassis slot 14 :This OID indicates the presence of a PM in Slot 14 of the Chassis . <Help> This status indicates if a PM is detected in slot 14 …
1.3.6.1.4.1.20044.7.2.1.17.4Scalarmgnt2AlmPmSlot15Absentread-onlycurrentPM present in Chassis slot 15 :This OID indicates the presence of a PM in Slot 15 of the Chassis . <Help> This status indicates if a PM is detected in slot 15 …
1.3.6.1.4.1.20044.7.2.1.17.5Scalarmgnt2AlmPmSlot16Absentread-onlycurrentPM present in Chassis slot 16 :This OID indicates the presence of a PM in Slot 16 of the Chassis . <Help> This status indicates if a PM is detected in slot 16 …
1.3.6.1.4.1.20044.7.2.1.17.6Scalarmgnt2AlmPmSlot17Absentread-onlycurrentPM present in Chassis slot 17 :This OID indicates the presence of a PM in Slot 17 of the Chassis . <Help> This status indicates if a PM is detected in slot 17 …
1.3.6.1.4.1.20044.7.2.1.17.7Scalarmgnt2AlmPmSlot18Absentread-onlycurrentPM present in Chassis slot 18 :This OID indicates the presence of a PM in Slot 18 of the Chassis . <Help> This status indicates if a PM is detected in slot 18 …
1.3.6.1.4.1.20044.7.2.1.17.8Scalarmgnt2AlmPmSlot19Absentread-onlycurrentPM present in Chassis slot 19 :This OID indicates the presence of a PM in Slot 19 of the Chassis . <Help> This status indicates if a PM is detected in slot 19 …
1.3.6.1.4.1.20044.7.2.1.17.9Scalarmgnt2AlmPmSlot20Absentread-onlycurrentPM present in Chassis slot 20 :This OID indicates the presence of a PM in Slot 20 of the Chassis . <Help> This status indicates if a PM is detected in slot 20 …
1.3.6.1.4.1.20044.7.2.1.20Nodemgnt2AlmfanMgmnt
1.3.6.1.4.1.20044.7.2.1.20.2Scalarmgnt2AlmPbFan1Failread-onlycurrentFan Unit #1 Failed On Fan Module :This OID indicates a failure on fan 1. Removal of the fan unit or no rotation sets the OID. <Help> This alarm indicates if th…
1.3.6.1.4.1.20044.7.2.1.20.3Scalarmgnt2AlmPbFan2Failread-onlycurrentFan Unit #2 Failed On Fan Module :This OID indicates a failure on fan 2. Removal of the fan unit or no rotation sets the OID. <Help> This alarm indicates if th…
1.3.6.1.4.1.20044.7.2.1.20.4Scalarmgnt2AlmPbFan3Failread-onlycurrentFan Unit #3 Failed On Fan Module :This OID indicates a failure on fan 3. Removal of the fan unit or no rotation sets the OID. <Help> This alarm indicates if th…
1.3.6.1.4.1.20044.7.2.1.20.5Scalarmgnt2AlmPbFan4Failread-onlycurrentFan Unit #4 Failed On Fan Module :This OID indicates a failure on fan 4. Removal of the fan unit or no rotation sets the OID. <Help> This alarm indicates if th…
1.3.6.1.4.1.20044.7.2.1.20.6Scalarmgnt2AlmPbFan5Failread-onlycurrentFan Unit #5 Failed On Fan Module :This OID indicates a failure on fan 5. Removal of the fan unit or no rotation sets the OID. <Help> This alarm indicates if th…
1.3.6.1.4.1.20044.7.2.1.20.7Scalarmgnt2AlmPbFan6Failread-onlycurrentFan Unit #6 Failed On Fan Module :This OID indicates a failure on fan 6. Removal of the fan unit or no rotation sets the OID. <Help> This alarm indicates if th…
1.3.6.1.4.1.20044.7.2.1.20.16Scalarmgnt2AlmFanFilterAbsentread-onlycurrentDust Filter Presence :This OID indicates that the dust filter is not present<Help> This alarm indicates if the Dust Filter is detected in the chassis. <Condtyp…
1.3.6.1.4.1.20044.7.2.1.24Nodemgnt2AlmfanPwrMgmnt
1.3.6.1.4.1.20044.7.2.1.24.12Scalarmgnt2AlmFanPwrProtOnread-onlycurrentFan Backup Power :This OID indicates the backup power on the FAN module is switched on <Condtype> FAN_PWR_PROT_ON <Probcause> powerProblem (36) <Alarmtype> equ…
1.3.6.1.4.1.20044.7.2.1.24.13Scalarmgnt2AlmFanPwrFail1read-onlycurrentFan Main Power :This OID indicates a failure on the main power of the FAN module <Help> This alarm indicates if one of the tow main power convert of the FAN mo…
1.3.6.1.4.1.20044.7.2.1.24.15Scalarmgnt2AlmFanDefFuseAread-onlycurrentFan Fuse A Fail :This OID indicates that the fuse of the power input A is in fail condition on the Fan board <Help> Status of the FAN Fuse A <Condtype> FAN_DEF…
1.3.6.1.4.1.20044.7.2.1.24.16Scalarmgnt2AlmFanDefFuseBread-onlycurrentFan Fuse B Fail :This OID indicates that the fuse of the power input B is in fail condition on the Fan board <Help> Status of the FAN Fuse B <Condtype> FAN_DEF…
1.3.6.1.4.1.20044.7.2.1.25Nodemgnt2AlmremoveablefanModuleFail
1.3.6.1.4.1.20044.7.2.1.25.1Scalarmgnt2AlmFan1ModuleAbsentread-onlycurrentFAN Module #1 Present In Chassis :This OID indicates the presence of the FAN module #1 in the Chassis.<Help> This alarm indicates if the FAN module #1 is detec…
1.3.6.1.4.1.20044.7.2.1.25.2Scalarmgnt2AlmFan2ModuleAbsentread-onlycurrentFAN Module #2 Present In Chassis :This OID indicates the presence of the FAN module #2 in the Chassis.<Help> This alarm indicates if the FAN module #2 is detec…
1.3.6.1.4.1.20044.7.2.1.25.3Scalarmgnt2AlmFan3ModuleAbsentread-onlycurrentFAN Module #3 Present In Chassis :This OID indicates the presence of the FAN module #3 in the Chassis.<Help> This alarm indicates if the FAN module #3 is detec…
1.3.6.1.4.1.20044.7.2.1.25.4Scalarmgnt2AlmFan4ModuleAbsentread-onlycurrentFAN Module #4 Present In Chassis :This OID indicates the presence of the FAN module #4 in the Chassis.<Help> This alarm indicates if the FAN module #4 is detec…
1.3.6.1.4.1.20044.7.2.1.26Nodemgnt2AlmremoveableFanModuleMgmnt
1.3.6.1.4.1.20044.7.2.1.26.1Scalarmgnt2AlmFan1ModuleFailread-onlycurrentFAN Module #1 Failure :This OID indicates a failure on FAN module #1 <Help> This alarm indicates if the FAN module #1 is in fail condition <Condtype> FAN1_MODU…
1.3.6.1.4.1.20044.7.2.1.26.2Scalarmgnt2AlmFan2ModuleFailread-onlycurrentFAN Module #2 Failure :This OID indicates a failure on FAN module #2 <Help> This alarm indicates if the FAN module #2 is in fail condition <Condtype> FAN2_MODU…
1.3.6.1.4.1.20044.7.2.1.26.3Scalarmgnt2AlmFan3ModuleFailread-onlycurrentFAN Module #3 Failure :This OID indicates a failure on FAN module #3 <Help> This alarm indicates if the FAN module #3 is in fail condition <Condtype> FAN3_MODU…
1.3.6.1.4.1.20044.7.2.1.26.4Scalarmgnt2AlmFan4ModuleFailread-onlycurrentFAN Module #4 Failure :This OID indicates a failure on FAN module #4 <Help> This alarm indicates if the FAN module #4 is in fail condition <Condtype> FAN4_MODU…
1.3.6.1.4.1.20044.7.2.1.32Nodemgnt2AlmswAlarm1
1.3.6.1.4.1.20044.7.2.1.32.1Scalarmgnt2AlmApiErrorread-onlycurrentComm fail between Agent and Transport :This OID indicates a failure detected on the Agent.The failure is located on a communication process with the modules. <…
1.3.6.1.4.1.20044.7.2.1.32.2Scalarmgnt2AlmFifoCmdErrorread-onlycurrentSNMP Agent to Transport comm FIFO fail :This OID indicates a failure inside the FIFO stack. The FIFO containing the messages from the agent (write) to the PMs …
1.3.6.1.4.1.20044.7.2.1.32.3Scalarmgnt2AlmPollingManagerErrorread-onlycurrentPolling Manager fail :This OID indicates a failure on the Manager polling the PM's <Help> <Help> This alarm indicates if there is a polling manager failure bet…
1.3.6.1.4.1.20044.7.2.1.33Scalarmgnt2AlmapiErrorCoderead-onlycurrentAPI Error Identification :Error number and description of the abs1AlmApiError object <Condtype> API_ERROR_CODE_1 <Probcause> <Alarmtype>
1.3.6.1.4.1.20044.7.2.1.34Nodemgnt2AlmlogMgmnt
1.3.6.1.4.1.20044.7.2.1.34.1Scalarmgnt2AlmLogFileFullread-onlycurrentLog File Full Alarm :This OID indicates that a log file is full. This file must be cleared to insure correct log function <Help> This alarm indicates that one …
1.3.6.1.4.1.20044.7.2.1.34.2Scalarmgnt2AlmLog80Fullread-onlycurrentLog File Full Warning :This OID indicates that a log file is 80% full. <Help> This alarm indicates that one of the log file is 80% Full <Condtype> LOG_80_FULL …
1.3.6.1.4.1.20044.7.2.1.35Nodemgnt2AlmntpSyncLoss
1.3.6.1.4.1.20044.7.2.1.35.1Scalarmgnt2AlmNtpSyncLossread-onlycurrentNTP Sync Loss :This OID indicates a loss of synchronisation with the NTP Server. <Help> This alarm indicates a loss of synchronisation with the NTP Server. <Co…
1.3.6.1.4.1.20044.7.2.1.35.2Scalarmgnt2AlmCpuTempOverRangeread-onlycurrentCPU HighTemperature Warning :This OID indicates a temperature over the expected range on the CPU<Help> This warning indicates that the temperature of the CPU i…
1.3.6.1.4.1.20044.7.2.2Nodemgnt2controls
1.3.6.1.4.1.20044.7.2.2.5Nodemgnt2Ctrlsynth5
1.3.6.1.4.1.20044.7.2.2.5.2Scalarmgnt2CtrlChassisShutdownread-writecurrentShut Down of the Management Module :This OID shall be set before shutting down the Chassis power. A delay of 5 sec is necessary between this OID is set and pow…
1.3.6.1.4.1.20044.7.2.2.5.3Scalarmgnt2CtrlChassisWarmResetread-writecurrentReset of the Management Module :This oid triggers a 'warm' reset of the Chassis . This type of reset is not traffic affecting and the modules configuration rem…
1.3.6.1.4.1.20044.7.2.2.5.4Scalarmgnt2CtrlChassisColdResetread-writecurrentCold Reset of the Management Module :This oid triggers a 'cold' reset of the Chassis . This type of reset is not traffic affecting and the modules configuratio…
1.3.6.1.4.1.20044.7.2.2.18Nodemgnt2CtrltestLed
1.3.6.1.4.1.20044.7.2.2.18.1Scalarmgnt2CtrlGreenLedread-writecurrentGreen Leds Test :This OID switches on all the green Leds as a test feature <Help> This control initiates a test leds turning all the LEDs of the chassis to gre…
1.3.6.1.4.1.20044.7.2.2.18.2Scalarmgnt2CtrlRedLedread-writecurrentRed Leds Test :This OID switches on all the red Leds as a test feature <Help> This control initiates a test leds turning all the LEDs of the chassis to red
1.3.6.1.4.1.20044.7.2.2.18.3Scalarmgnt2CtrlLedOffread-writecurrentSwitch off Leds Test :This OID switches off all the Leds as a test feature <Help> This control initiates a test leds turning all the LEDs of the complete chass…
1.3.6.1.4.1.20044.7.2.2.19Nodemgnt2CtrllogFile
1.3.6.1.4.1.20044.7.2.2.19.1Scalarmgnt2CtrlLogFileResetread-writecurrentLog File Reset :This OID clears all the log files
1.3.6.1.4.1.20044.7.2.2.23Nodemgnt2CtrlmgntSaveConfig
1.3.6.1.4.1.20044.7.2.2.23.1Scalarmgnt2CtrlSaveConfigread-writecurrentSave Configuration :This OID is used save the configuration related to the enable and mode traps objects <Help> This control saves the customer configuration o…
1.3.6.1.4.1.20044.7.2.2.24Nodemgnt2CtrlmgntGetGlobalConfig
1.3.6.1.4.1.20044.7.2.2.24.1Scalarmgnt2CtrlGetGlobalConfigread-writecurrentGet Global Chassis Config :This OID is used to create a global configuration file of the chassis <Help> This control creates a single configuration file from P…
1.3.6.1.4.1.20044.7.2.2.25Nodemgnt2CtrlmgntPutGlobalConfig
1.3.6.1.4.1.20044.7.2.2.25.1Scalarmgnt2CtrlPutGlobalConfigread-writecurrentPut Global Chassis Config :This OID is used to extract a global configuration file of the chassis <Help> This control creates configuration files to PM's and M…
1.3.6.1.4.1.20044.7.2.2.26Nodemgnt2CtrlmgntAcknowledge
1.3.6.1.4.1.20044.7.2.2.26.1Scalarmgnt2CtrlAcknowledgeread-writecurrentAlarm Ack. :This OID is used to acknowledge the current active alarms of the chassis <Help> This control is used to acknowledge the current active alarms of th…
1.3.6.1.4.1.20044.7.2.3Nodemgnt2config
1.3.6.1.4.1.20044.7.2.3.17Nodemgnt2CfgethPort2
1.3.6.1.4.1.20044.7.2.3.17.1Scalarmgnt2CfgEthPort2Disableread-writecurrent2nd Ethernet Port Disable :This OID disables 'Ethernet Port 2' .When not required, this port must be disabled in order to prevent unwanted access. <Help> Disab…
1.3.6.1.4.1.20044.7.2.3.17.2Scalarmgnt2CfgChassisEthernetSplitread-writecurrentChassis Ethernet Split :This OID enables the split between the two kendings. <Help> Enable/Disable the switch between the two kendings
1.3.6.1.4.1.20044.7.2.3.18Scalarmgnt2CfgmgntDccEnableread-writecurrentDCC Access :This OID selects the mode to enable the DCC on the slots. This Mode enables the Slots 2-4-6-8-10 , or the Slots 2-6-10-14-18. <Help> Defines the DC…
1.3.6.1.4.1.20044.7.2.3.20Nodemgnt2CfgpmTrapEnable
1.3.6.1.4.1.20044.7.2.3.20.1Scalarmgnt2CfgPmCriticalTrapEnread-writecurrentCritical Alarm Traps Enable :This OID, when set, enables the generation of the critical alarm trap for all the PM plugged in the chassis <Help> In detailed tra…
1.3.6.1.4.1.20044.7.2.3.20.2Scalarmgnt2CfgPmMajorTrapEnread-writecurrentMajor Alarm Traps Enable :This OID, when set, enables the generation of the major alarm trap for all the PM plugged in the chassis <Help> In detailed traps mec…
1.3.6.1.4.1.20044.7.2.3.20.3Scalarmgnt2CfgPmMinorTrapEnread-writecurrentMinor Alarm Traps Enable :This OID, when set, enables the generation of the minor alarm trap for all the PM plugged in the chassis <Help> In detailed traps mec…
1.3.6.1.4.1.20044.7.2.3.20.5Scalarmgnt2CfgPmControlTrapEnread-writecurrentControl Traps Enable :This OID, when set, enables the generation of a trap when a control is sent to a PM plugged in the chassis <Help> In detailed traps mecha…
1.3.6.1.4.1.20044.7.2.3.20.6Scalarmgnt2CfgPmConfigTrapEnread-writecurrentConfig Traps Enable :This OID, when set, enables the generation of a trap when the configuration of a PM plugged in the chassis is modified <Help> In detailed …
1.3.6.1.4.1.20044.7.2.3.21Nodemgnt2CfgmgntTrapEnable
1.3.6.1.4.1.20044.7.2.3.21.1Scalarmgnt2CfgMgntCriticalTrapEnread-writecurrentMGNT Critical Alarm Traps Enable :This OID, when set, enables the generation of the critical alarm trap for the MGNT and FAN board <Help> In detailed traps mec…
1.3.6.1.4.1.20044.7.2.3.21.2Scalarmgnt2CfgMgntMajorTrapEnread-writecurrentMGNT Major Traps Enable :This OID, when set, enables the generation of the major alarm trap for the MGNT and FAN board <Help> In detailed traps mechanism, enab…
1.3.6.1.4.1.20044.7.2.3.21.3Scalarmgnt2CfgMgntMinorTrapEnread-writecurrentMGNT Minor Alarm Traps Enable :This OID, when set, enables the generation of the minor alarm trap for the MGNT and FAN board <Help> In detailed traps mechanism…
1.3.6.1.4.1.20044.7.2.3.21.5Scalarmgnt2CfgMgntControlTrapEnread-writecurrentMGNT Control Traps Enable :This OID, when set, enables the generation of a trap when a control is sent to a MGNT plugged in the chassis <Help> In detailed trap…
1.3.6.1.4.1.20044.7.2.3.21.6Scalarmgnt2CfgMgntConfigTrapEnread-writecurrentMGNT Config Traps Enable :This OID, when set, enables the generation of a trap when the configuration of a MGNT plugged in the chassis is modified <Help> In de…
1.3.6.1.4.1.20044.7.2.3.21.7Scalarmgnt2CfgMgntEventTrapEnread-writecurrentMGNT Event Traps Enable :This OID, when set, enables the generation of a trap when an event occurs on the chassis <Help> In detailed traps mechanism, enable th…
1.3.6.1.4.1.20044.7.2.3.22Scalarmgnt2CfgmgntTrapModeread-writecurrentTraps Mode :This OID is used to define the trap mode (synthetic or detailed mode) <Help> Selects the traps mechanism
1.3.6.1.4.1.20044.7.2.3.23Nodemgnt2CfgsyslogEnable
1.3.6.1.4.1.20044.7.2.3.23.1Scalarmgnt2CfgSyslogEventEnread-writecurrentSyslog Event Enable :This OID, when set, enables the generation of a syslog, when an event has been detected <Help> Enable a syslog emission on event detected …
1.3.6.1.4.1.20044.7.2.3.23.2Scalarmgnt2CfgSyslogConfigEnread-writecurrentSyslog Config Enable :This OID, when set, enables the generation of a syslog, when the configuration has been changed. <Help> Enable a syslog emission on a con…
1.3.6.1.4.1.20044.7.2.3.23.3Scalarmgnt2CfgSyslogCtrlEnread-writecurrentSyslog Control Enable :This OID, when set, enables the generation of a syslog, when a control is set <Help> Enable a syslog emission on a control operated on t…
1.3.6.1.4.1.20044.7.2.3.23.4Scalarmgnt2CfgSyslogAlarmEnread-writecurrentSyslog Alarm Enable :This OID, when set, enables the generation of a syslog, when an alarm occurs <Help> Enable a syslog emission on an alarm detected on the c…
1.3.6.1.4.1.20044.7.2.3.24Scalarmgnt2CfgntpTimeZoneread-writecurrentNTP Time Zone :This OID defines the time zone of the MGNT board for the NTP server <Help> This object defines the time zone of the MGNT board (from -12 to +12 …
1.3.6.1.4.1.20044.7.2.3.25Nodemgnt2CfgpmConfEnable
1.3.6.1.4.1.20044.7.2.3.25.1Scalarmgnt2CfgPmBackupEnableread-writecurrentAutomatic Config Backup :This OID enables the automatic PM configuration backup mechanism on PM insertion or PM configuration modification. <Help> This paramet…
1.3.6.1.4.1.20044.7.2.3.25.2Scalarmgnt2CfgPmRestoreEnableread-writecurrentAutomatic Config Restore :This OID enables the automatic PM configuration restore mechanism on PM insertion <Help> This parameter enables the automatic PM conf…
1.3.6.1.4.1.20044.7.2.3.26Scalarmgnt2CfginactivityTimeoutread-writecurrentIdle Timeout :This OID defines the idle timeout (in minutes) to automatically logout from the craft and from the CLI. <Help> This object defines the idle timeo…
1.3.6.1.4.1.20044.7.2.3.27Scalarmgnt2CfgcliAccessread-writecurrentCLI access :This OID selects the protocol for the remote access to a CLI user. <Help> This object defines the protocol used for a remote CLI.
1.3.6.1.4.1.20044.7.2.3.28Scalarmgnt2CfgcraftAccessread-writecurrentCRAFT access :This OID selects the remote access to a CRAFT user. <Help> This object defines the access for a remote CRAFT.
1.3.6.1.4.1.20044.7.2.3.29Scalarmgnt2CfgperfModes1read-writecurrentPERF Synchro Source :This OID selects the source of the synchronisation (Internal/External). <Help> This object defines the source of the synchronization to op…
1.3.6.1.4.1.20044.7.2.3.30Scalarmgnt2CfgalarmModelActivread-writecurrentAcknowledge mode :This OID defines the alarms akcnowledge mode <Help> This configuration defines the alarms akcnowledge mode
1.3.6.1.4.1.20044.7.2.3.31Scalarmgnt2CfgnetworkInputread-writecurrentNetwork input :This OID selects the connection of the Ethernet Network input to either the switches (2) or the daughter board (1) , in this case the MGNT can a…
1.3.6.1.4.1.20044.7.2.3.32Scalarmgnt2CfgmasterEthModeread-writecurrentDHCP Master Ethernet Mode :This OID selects the mode of the Master Ethernet in DHCP mode (2) or in Static Mode(1) <Help> This configuration defines the use of …
1.3.6.1.4.1.20044.7.2.3.33Scalarmgnt2CfgsubnetModeread-writecurrentDHCP Subnet Mode :This OID selects the mode of the Subnet in DHCP mode (2) or in Static Mode(1) <Help> This configuration defines the use of the Subnet Mode
1.3.6.1.4.1.20044.7.2.3.34Nodemgnt2CfgrstpMode
1.3.6.1.4.1.20044.7.2.3.34.1Scalarmgnt2CfgRstpEnableread-writecurrentRSTP Enable :This OID enables the RSTP algorythm <Help> This configuration defines the use of RSTP
1.3.6.1.4.1.20044.7.2.3.35Nodemgnt2CfglldpMode
1.3.6.1.4.1.20044.7.2.3.35.1Scalarmgnt2CfgLldpEnableread-writecurrentLLDP Enable :This OID enables the LLDP algorythm <Help> This configuration defines the use of LLDP
1.3.6.1.4.1.20044.7.2.3.36Scalarmgnt2CfglogModeread-writecurrentLog Mode :This OID enables the log file mode<Help> This configuration defines the use of the log mod
1.3.6.1.4.1.20044.7.2.3.37Nodemgnt2CfgnodeMode
1.3.6.1.4.1.20044.7.2.3.37.1Scalarmgnt2CfgNodeControllerEnableread-writecurrentNode Controller Mode :This OID enables the node controller mode<Help> This configuration defines the use of the node controller mod
1.3.6.1.4.1.20044.7.2.3.38Nodemgnt2CfgunprivilegedUsersMode
1.3.6.1.4.1.20044.7.2.3.38.1Scalarmgnt2CfgRestrictUnprivilegeUsersread-writecurrentRestrict Unprivileged Users Rights :This OID enables the restriction of unprivileged user rights to modify their own password <Help> This parameter enables the…
1.3.6.1.4.1.20044.7.2.3.39Scalarmgnt2CfgoscDccLinkUpThresholdread-writecurrentOSC/DCC Link Up Thresh. [10-30]s :This OID defines the confirmation threshold to consider an OSC/DCC link as up <Help> This parameter defines the confirmation …
1.3.6.1.4.1.20044.7.2.3.40Scalarmgnt2CfgoscDccLinkDownThresholdread-writecurrentOSC/DCC Link Down Thresh. [2-3]s :This OID defines the confirmation threshold to consider an OSC/DCC link as down <Help> This parameter defines the confirmatio…
1.3.6.1.4.1.20044.7.2.3.41Scalarmgnt2CfgaccountAutoLockread-writecurrentAccount Auto-Lock [-1 / 1-10] err :This OID defines the number of error password to lock an account. This counter is reset on successful login or after an admi…
1.3.6.1.4.1.20044.7.2.3.42Scalarmgnt2CfgfailCountResetread-writecurrentFail Count Reset [-1 / 1-10] hrs :This OID defines the minimum time (in hours) to reset the failed login counter. This counter is also reset on successful logi…
1.3.6.1.4.1.20044.7.2.3.44Nodemgnt2CfgftpMode
1.3.6.1.4.1.20044.7.2.3.44.1Scalarmgnt2CfgFtpEnableread-writecurrentFTP Enable :This OID enables the FTP protocol <Help> This configuration enables the FTP protocol
1.3.6.1.4.1.20044.7.2.3.45Nodemgnt2CfgtftpMode
1.3.6.1.4.1.20044.7.2.3.45.1Scalarmgnt2CfgTftpEnableread-writecurrentTFTP Enable :This OID enables the TFTP protocol <Help> This configuration enables the TFTP protocol
1.3.6.1.4.1.20044.7.3Nodemgnt2Traps
1.3.6.1.4.1.20044.7.3.1Notificationmgnt2TrapApicurrentApi error trap with its number
1.3.6.1.4.1.20044.7.3.2Notificationmgnt2TrapSwErrorcurrentChassis software error other API
1.3.6.1.4.1.20044.7.3.4Notificationmgnt2TrapBoardInsertedcurrentA board has been plugged in
1.3.6.1.4.1.20044.7.3.5Notificationmgnt2TrapBoardRemovedcurrentA board has been plugged out
1.3.6.1.4.1.20044.7.3.6Notificationmgnt2TrapRestoreConfDonecurrentThe Configuration has been restored from the management board
1.3.6.1.4.1.20044.7.3.8Notificationmgnt2TrapGlobalPowerFailcurrentA global power supply failure has been detected
1.3.6.1.4.1.20044.7.3.9Notificationmgnt2TrapFanPowerFailcurrentA Fan power supply failure has been detected
1.3.6.1.4.1.20044.7.3.10Notificationmgnt2TrapGigmPowerFailcurrentA power supply default has been detected in the management board
1.3.6.1.4.1.20044.7.3.11Notificationmgnt2TrapFanFailcurrentA Fan failure has been detected
1.3.6.1.4.1.20044.7.3.20Notificationmgnt2TrapLogFileFullcurrentIndicates that the corresponding log file is almost full
1.3.6.1.4.1.20044.7.3.30Notificationmgnt2TrapAlarmcurrentIndicates that an alarm state has changed
1.3.6.1.4.1.20044.7.3.31Notificationmgnt2TrapEventcurrentIndicates that an event has occured
1.3.6.1.4.1.20044.7.3.32Notificationmgnt2TrapControlcurrentIndicates that a control has been set to the module
1.3.6.1.4.1.20044.7.3.33Notificationmgnt2TrapConfigcurrentIndicates that a config word has been changed
1.3.6.1.4.1.20044.7.3.50Scalarmgnt2TrapBoardNumberread-onlycurrentThis OID gives the slot number of the PM that sent the last trap
1.3.6.1.4.1.20044.7.3.51Scalarmgnt2TrapSeverityread-onlycurrentThis OID gives the trap severity
1.3.6.1.4.1.20044.7.3.52Scalarmgnt2TrapSourcePmread-onlycurrentThis OID gives the mnemonic of the pm who sent a trap
1.3.6.1.4.1.20044.7.3.53Scalarmgnt2TrapSourcePortTyperead-onlycurrentThis OID gives the type of the port who sent a trap
1.3.6.1.4.1.20044.7.3.54Scalarmgnt2TrapSourcePortNumberread-onlycurrentThis OID gives the port number of the PM that sent the last trap
1.3.6.1.4.1.20044.7.3.55Scalarmgnt2TrapSourceLabelread-onlycurrentThis OID gives the label of the alarm who sent a trap
1.3.6.1.4.1.20044.7.3.56Scalarmgnt2TrapSourceValueread-onlycurrentThis OID gives the value of the alarm who sent a trap
1.3.6.1.4.1.20044.7.3.57Scalarmgnt2TrapEventLabelread-onlycurrentThis OID gives the label of the event
1.3.6.1.4.1.20044.7.3.58Scalarmgnt2TrapNodeControllerIpAddressread-onlycurrentThis OID gives the IP address of the Node Controller
1.3.6.1.4.1.20044.7.3.59Scalarmgnt2TrapChassisIdread-onlycurrentThis OID gives the chassis ID
1.3.6.1.4.1.20044.7.4Nodemgnt2SoftwareManagement
1.3.6.1.4.1.20044.7.4.1Tablemgnt2DwlUploadingTablenot-accessibledeprecatedSNMP Agent SW packages in ram: List of the SNMP agent software packages available in /ram for download on the Chassis managment module flash
1.3.6.1.4.1.20044.7.4.1.1Rowmgnt2DwlUploadingEntrynot-accessibledeprecatedRow definition for the package uploading table
1.3.6.1.4.1.20044.7.4.1.1.1Columnmgnt2IndexUploadread-onlydeprecatedIndex for uploading table
1.3.6.1.4.1.20044.7.4.1.1.2Columnmgnt2DwlUploadFileNameread-onlydeprecatedPackage filename in RAM:This OID gives the name of the SNMP agent software packages in RAM
1.3.6.1.4.1.20044.7.4.1.1.3Columnmgnt2ImmediateReplacementread-writedeprecatedImmediat Agent Replacement:This OID indicates to switch to selected SNMP agent immediately or after reset of the MGNT2
1.3.6.1.4.1.20044.7.4.1.1.4Columnmgnt2FileUploadread-writedeprecatedAgent File Upload:This OID validates the upload of the SNMP agent from RAM to FLASH
1.3.6.1.4.1.20044.7.4.1.1.5Columnmgnt2DeletePackageFromRamread-writedeprecatedDelete Package from RAM:This OID requests to delete the SNMP Agent SW package from RAM
1.3.6.1.4.1.20044.7.4.1.1.6Columnmgnt2FlashingInProgressread-onlydeprecatedFlashing in Progress:This OID indicates whether there is a file upload to FLASH in progress
1.3.6.1.4.1.20044.7.4.2Tablemgnt2DwlPackageTablenot-accessibledeprecatedList of SNMP agent software packages present in flash memory
1.3.6.1.4.1.20044.7.4.2.1Rowmgnt2DwlPackageEntrynot-accessibledeprecatedRow definition for the package management table
1.3.6.1.4.1.20044.7.4.2.1.1Columnmgnt2IndexPackageread-onlydeprecatedIndex for package management table
1.3.6.1.4.1.20044.7.4.2.1.2Columnmgnt2DwlPackageFileNameread-onlydeprecatedPackage File name in FLASH:This OID gives the name of the SNMP agent software package in FLASH
1.3.6.1.4.1.20044.7.4.2.1.3Columnmgnt2ExtractedPackread-onlydeprecatedExtracted SNMP agent software pack.: Indicates whether the package is currently extracted in the FLASH. If it is, it must not be deleted
1.3.6.1.4.1.20044.7.4.2.1.4Columnmgnt2SwitchToread-writedeprecatedSwitch to package:This OID activates the SNMP Agent Software package
1.3.6.1.4.1.20044.7.4.2.1.5Columnmgnt2Immediateread-writedeprecatedImmediate SNMP agent activation: This OID indicates whether the package is scheduled for immediate activation or activation will take place following the next …
1.3.6.1.4.1.20044.7.4.2.1.6Columnmgnt2DeletePackageFromFlashread-writedeprecatedDelete package from FLASH:This OID deletes the SNMP agent software package from the FLASH
1.3.6.1.4.1.20044.7.4.2.1.7Columnmgnt2PackageExtractionInProgressread-onlydeprecatedPackage extraction in progress:This OID indicates that a SNMP agent software activation is in progress
1.3.6.1.4.1.20044.7.4.3Scalarmgnt2DwlUploadingTableUpdateread-writedeprecatedUploading Table update:This OID updates the contents of the uploading table
1.3.6.1.4.1.20044.7.4.4Tablemgnt2LoadPMTablenot-accessibledeprecatedList of the PM module software files (GW/SW) present on the repository
1.3.6.1.4.1.20044.7.4.4.1Rowmgnt2LoadPMEntrynot-accessibledeprecatedRow definition for the LOAD article table
1.3.6.1.4.1.20044.7.4.4.1.1Columnmgnt2LoadPMIndexread-onlydeprecatedIndex for Load article table
1.3.6.1.4.1.20044.7.4.4.1.2Columnmgnt2LoadFileNameread-onlydeprecatedPM Upgrade filename:This OID gives the name of the file
1.3.6.1.4.1.20044.7.4.4.1.3Columnmgnt2LoadFileTyperead-onlydeprecatedPM upgrade file type:This OID gives the type of file (gateware or software)
1.3.6.1.4.1.20044.7.4.4.1.4Columnmgnt2LoadStateread-onlydeprecatedPM upgrade status:This OID gives the status of the selected Load file
1.3.6.1.4.1.20044.7.4.4.1.5Columnmgnt2LoadModuleNumberread-writedeprecatedPM ugprade target:This OID defines the slot number of the PM to upgrade
1.3.6.1.4.1.20044.7.4.4.1.6Columnmgnt2LoadResetMethodread-writedeprecatedPM upgrade reset method:This OID defines the reset method (manual, immediate or scheduled)
1.3.6.1.4.1.20044.7.4.4.1.7Columnmgnt2LoadResetModeread-writedeprecatedPM upgrade reset mode:This OID defines the type of reset (cold or warm)
1.3.6.1.4.1.20044.7.4.4.1.8Columnmgnt2LoadBankNumberread-writedeprecatedPM upgrade bank number:This OID defines the target bank number in the PM's flash
1.3.6.1.4.1.20044.7.4.4.1.9Columnmgnt2LoadDownloadProgressread-onlydeprecatedPM upgrade progress:This OID gives the upgrade progress (percentage)
1.3.6.1.4.1.20044.7.4.4.1.10Columnmgnt2LoadTransferread-writedeprecatedPM upgrade transfer:This OID launchs the transfer of the associated file to the selected PM's flash
1.3.6.1.4.1.20044.7.4.4.1.11Columnmgnt2LoadDeleteread-writedeprecatedPM upgrade delete file:This OID deletes the associated file from the RAM of the management board
1.3.6.1.4.1.20044.7.4.5Scalarmgnt2LoadPMTableUpdateread-writedeprecatedLoad PM Table update:This OID updates the contents of the Load table
1.3.6.1.4.1.20044.7.4.6Tablemgnt2DwlEkicraftPkgTablenot-accessibledeprecatedList of Ekicraft software packages present in flash memory
1.3.6.1.4.1.20044.7.4.6.1Rowmgnt2DwlEkicraftPkgEntrynot-accessibledeprecatedRow definition for the package management table
1.3.6.1.4.1.20044.7.4.6.1.1Columnmgnt2IndexEkicraftPkgread-onlydeprecatedIndex for Ekicraft package management table
1.3.6.1.4.1.20044.7.4.6.1.2Columnmgnt2DwlEkicraftPkgFileNameread-onlydeprecatedPackage File name in FLASH:This OID gives the name of the Ekicraft software package in FLASH
1.3.6.1.4.1.20044.7.4.6.1.3Columnmgnt2DwlEkicraftExtractedPackread-onlydeprecatedExtracted Ekicraft software pack.: Indicates whether the package is currently extracted in the FLASH. If it is, it must not be deleted
1.3.6.1.4.1.20044.7.4.6.1.4Columnmgnt2DwlEkicraftSwitchToread-writedeprecatedSwitch to package:This OID activates the Ekicraft Software package
1.3.6.1.4.1.20044.7.4.6.1.5Columnmgnt2DwlEkicraftImmediateread-writedeprecatedImmediate Ekicraft activation: This OID indicates whether the package is scheduled for immediate activation or activation will take place following the next re…
1.3.6.1.4.1.20044.7.4.6.1.6Columnmgnt2DeleteEkicraftPkgFromFlashread-writedeprecatedDelete package from FLASH:This OID deletes the Ekicraft software package from the FLASH
1.3.6.1.4.1.20044.7.4.6.1.7Columnmgnt2EkicraftPkgExtractionInProgressread-onlydeprecatedPackage extraction in progress:This OID indicates that an Ekicraft activation is in progress
1.3.6.1.4.1.20044.7.5Nodemgnt2ConfigManagement
1.3.6.1.4.1.20044.7.5.1Tablemgnt2CnfUploadConfigFilesTablenot-accessibledeprecatedList of configuration files uploaded to RAM
1.3.6.1.4.1.20044.7.5.1.1Rowmgnt2CnfUploadConfigFilesEntrynot-accessibledeprecatedRow definition for the package uploading table
1.3.6.1.4.1.20044.7.5.1.1.1Columnmgnt2CnfUploadConfigIndexread-onlydeprecatedIndex of config files
1.3.6.1.4.1.20044.7.5.1.1.2Columnmgnt2CnfConfigFileNameread-onlydeprecatedConfiguration filename in RAM:This OID gives the name of the configuration file in RAM
1.3.6.1.4.1.20044.7.5.1.1.3Columnmgnt2CnfConfigSlotread-writedeprecatedConfiguration target:This OID defines the target slot number for the configuration file
1.3.6.1.4.1.20044.7.5.1.1.4Columnmgnt2CnfConfigUploadread-writedeprecatedConfiguration Upload:This OID uploads the configuration file to the specified slot number in the PM FLASH
1.3.6.1.4.1.20044.7.5.1.1.5Columnmgnt2CnfDeleteConfigFileread-writedeprecatedConfiguration delete from RAM:This OID deletes the configuration file from RAM
1.3.6.1.4.1.20044.7.5.2Tablemgnt2CnfManageConfigFilesTablenot-accessibledeprecatedList of configuration files uploaded to RAM
1.3.6.1.4.1.20044.7.5.2.1Rowmgnt2CnfManageConfigFilesEntrynot-accessibledeprecatedRow definition for the package uploading table
1.3.6.1.4.1.20044.7.5.2.1.1Columnmgnt2CnfManageConfigIndexread-onlydeprecatedIndex of config file slots
1.3.6.1.4.1.20044.7.5.2.1.2Columnmgnt2CnfManageConfigFileIDread-writedeprecatedConfiguration file ID in FLASH:This OID gives the ID of the configuration file in MGNT2 FLASH
1.3.6.1.4.1.20044.7.5.2.1.3Columnmgnt2CnfManageConfigFileNameread-writedeprecatedConfiguration file name in FLASH:This OID gives the name of the configuration file in MGNT2 FLASH
1.3.6.1.4.1.20044.7.5.2.1.4Columnmgnt2CnfModuleSlotNumberread-writedeprecatedConfiguration target:This OID defines the target module slot number for the configuration file
1.3.6.1.4.1.20044.7.5.2.1.5Columnmgnt2CnfBackupConfigread-writedeprecatedConfiguration backup:This OID backups the configuration of the specified module to the selected file in MGNT2 FLASH
1.3.6.1.4.1.20044.7.5.2.1.6Columnmgnt2CnfRestoreConfigread-writedeprecatedConfiguration Restore:This OID restores the configuration of the specified module from the selected file in MGNT2 FLASH
1.3.6.1.4.1.20044.7.5.2.1.7Columnmgnt2CnfExportConfigread-writedeprecatedConfiguration Export:This OID exports the selected file in MGNT2 FLASH to a file in RAM
1.3.6.1.4.1.20044.7.5.2.1.8Columnmgnt2CnfDeleteConfigread-writedeprecatedConfiguration delete from FLASH:This OID deletes the configuration file from the MGNT2 FLASH
1.3.6.1.4.1.20044.7.6Nodemgnt2RemoteInventory
1.3.6.1.4.1.20044.7.6.1Scalarmgnt2RinvHwPlatformread-writecurrentChassis Hardware inventory:This OID gives the Hardware inventory of the Mgnt2 management module
1.3.6.1.4.1.20044.7.6.2Scalarmgnt2RinvSoftwarePackageread-writecurrentChassis Software package inventory:this OID gives the Software package inventory of the Mgnt2 management module
1.3.6.1.4.1.20044.7.6.3Scalarmgnt2RinvGatewareread-writecurrentChassis Gateware inventory:This OID gives the gateware inventory of the Mgnt2 management module
1.3.6.1.4.1.20044.7.6.4Scalarmgnt2RinvAgentread-writecurrentChassis Software inventory:This OID gives the software inventory of the Mgnt2 management module
1.3.6.1.4.1.20044.7.6.5Scalarmgnt2RinvCraftread-writecurrentChassis Craft inventory:This OID gives the craft inventory of the Mgnt2 management module
1.3.6.1.4.1.20044.7.6.6Scalarmgnt2RinvLinuxread-writecurrentChassis Linux inventory:This OID gives the linux inventory of the Mgnt2 management module
1.3.6.1.4.1.20044.7.6.7Tablemgnt2GigmPlugInTablenot-accessiblecurrentList of Plug-ins present
1.3.6.1.4.1.20044.7.6.7.1Rowmgnt2GigmPlugInEntrynot-accessiblecurrentRow Definition for the Plug-ins table
1.3.6.1.4.1.20044.7.6.7.1.1Columnmgnt2IndexPlugInsread-onlycurrentIndex for PMs table
1.3.6.1.4.1.20044.7.6.7.1.2Columnmgnt2PlugInRinvread-onlycurrentPlug-in RI:This OID gives the remote inventory of the plug-in
1.3.6.1.4.1.20044.7.6.7.1.3Columnmgnt2PollingPresentread-onlycurrentPolling present:This OID gives the presence of the polling plug-in
1.3.6.1.4.1.20044.7.6.7.1.4Columnmgnt2SnmpPresentread-onlycurrentSnmp present:This OID gives the presence of the snmp plug-in
1.3.6.1.4.1.20044.7.6.8Scalarmgnt2RinvBackpanelread-writecurrentBackpanel inventory:This OID gives the Backpanel inventory of the chassis
1.3.6.1.4.1.20044.7.6.9Scalarmgnt2RinvFanread-writecurrentFan inventory:This OID gives the fan inventory of the chassis
1.3.6.1.4.1.20044.7.6.10Scalarmgnt2RinvUbootread-writecurrentU-Boot inventory:This OID gives the U-Boot inventory
1.3.6.1.4.1.20044.7.7Nodemgnt2ErrorCounters
1.3.6.1.4.1.20044.7.7.1Tablemgnt2GigmErrorCounterTablenot-accessiblecurrentList of error counters
1.3.6.1.4.1.20044.7.7.1.1Rowmgnt2GigmErrorCounterEntrynot-accessiblecurrentRow Definition for the error counters table
1.3.6.1.4.1.20044.7.7.1.1.1Columnmgnt2IndexErrorCounterread-onlycurrentIndex for error counters table
1.3.6.1.4.1.20044.7.7.1.1.2Columnmgnt2ErrorCounterSlotNumberread-onlycurrentSlot number:This OID gives the slot number for the corresponding counter
1.3.6.1.4.1.20044.7.7.1.1.3Columnmgnt2ErrorCounterValueread-onlycurrentCount value:This OID gives the value of the error counter
1.3.6.1.4.1.20044.7.7.2Scalarmgnt2GigmResetErrorCountersread-writecurrentReset error counters:This OID reset the error counters to 0
1.3.6.1.4.1.20044.7.8Nodemgnt2Perf
1.3.6.1.4.1.20044.7.8.1Tablemgnt2PerfCapabilityTablenot-accessiblecurrentList of Perf capability of PMs plugged in the Chassis
1.3.6.1.4.1.20044.7.8.1.1Rowmgnt2PerfCapabilityEntrynot-accessiblecurrentRow Definition for the Perf capability table
1.3.6.1.4.1.20044.7.8.1.1.1Columnmgnt2PerfCapIndexBoardsread-onlycurrentIndex for Perf cap table
1.3.6.1.4.1.20044.7.8.1.1.2Columnmgnt2PerfCapPositionread-onlycurrentPM Slot number:This OID gives the slot number in which the PM is plugged
1.3.6.1.4.1.20044.7.8.1.1.3Columnmgnt2PerfCapNameread-onlycurrentPM name:This OID gives the name of the PM plugged in the Mgnt2
1.3.6.1.4.1.20044.7.8.1.1.4Columnmgnt2PerfCapStatusread-onlycurrentStatus of the perf cap:This OID gives the capability of the pm to do performance
1.3.6.1.4.1.20044.7.8.1.1.5Columnmgnt2PerfCapOidEnableread-onlycurrentOID of the object perf enable:This OID gives the OID of the perf enable object of the correspondind mib of the module
1.3.6.1.4.1.20044.7.8.2Scalarmgnt2GigmPerf15minSyncread-writecurrent15 min sync perf : this oid send a 15min sync to all modules
1.3.6.1.4.1.20044.7.8.3Scalarmgnt2GigmPerf24hSyncread-writecurrent15 min sync perf : this oid send a 24h sync to all modules
1.3.6.1.4.1.20044.7.8.4Scalarmgnt2PerfResyncNMSread-writecurrentResync Perf : this oid allows to create an historical perf file for all modules
Type Definitions
NameSyntaxStatusDescription
EkiPlugInStateINTEGER { absent(0), loaded(1), versionError(2), symbolError(3) }currentPlug-in state
Mgnt2AckModeINTEGER { modeA(1), modeB(2) }currentdifferent modes to acknowledge alarms
Mgnt2AuthTypeValuesINTEGER { authLocal(0), authRADIUS(1), authLDAP(2) }currentVarious types of authentication processes
Mgnt2CliAccessValuesINTEGER { noCliByEthernet(0), cliBySSH(1), cliByTelnet(2) }currentdifferent type of access by ethernet for the CLI
Mgnt2CraftAccessValuesINTEGER { noCraftAccess(0), craftEnable(1), craftEnableHttps(2) }currentenables access to the CRAFT
Mgnt2DccAccessValuesINTEGER { mode1Slots2s4s6s8s10(0), mode2Slots2s6s10s14s18(1) }currentdifferent modes for the Dcc access
Mgnt2LogFileModeINTEGER { disabled (0), linear(1), rotary(2) }currentdifferent modes for the log files
Mgnt2MasterEthModeINTEGER { static(1), dhcp(2) }currentdifferent modes for the Master
Mgnt2NetModeINTEGER { switch(1), gateway(2) }currentdifferent modes for the network management
Mgnt2PerfResyncValuesINTEGER { perfResyncIdle(1), perfResyncSync(2), perfResyncReady(3), perfResyncDelete(4) }currentdifferent modes for the trap generation
Mgnt2SlotStatusINTEGER { slotEmpty(0), pmReady(1), pmReset(2), pmLoad(3), pmPassive(4), pmUnknown(5), pmNotReady(6) }currentStatus of the slot
Mgnt2SubnetEthModeINTEGER { static(1), dhcp(2) }currentdifferent modes for the Subnet
Mgnt2TrapModeValuesINTEGER { syntheticTrap(0), detailedTrap(1), nmsTrap(2) }currentdifferent modes for the trap generation