EKINOPS-PMC1002-MIB
932 objects
MIB for managing Ekinops modules with PM1002 software
Imported Objects
| EKINOPS-MIB | EkiApiState EkiMeasureType EkiMode ekinops EkiOnOff EkiProtocol EkiState EkiSynchroMode |
| SNMPv2-SMI | Counter32 Integer32 IpAddress MODULE-IDENTITY NOTIFICATION-TYPE OBJECT-TYPE Unsigned32 |
| SNMPv2-TC | DisplayString TEXTUAL-CONVENTION |
| OID | Name | Access | Status | Description |
|---|---|---|---|---|
| 1.3.6.1.4.1.20044.50 | Identitymodulepmc1002 | MIB for managing Ekinops modules with PM1002 software | ||
| 1.3.6.1.4.1.20044.50.2 | Nodepmc1002alarms | |||
| 1.3.6.1.4.1.20044.50.2.1 | Nodepmc1002AlmOther | |||
| 1.3.6.1.4.1.20044.50.2.1.1 | Nodepmc1002AlmOtherNurg | |||
| 1.3.6.1.4.1.20044.50.2.1.1.2 | Nodepmc1002AlmsynthAlm2 | |||
| 1.3.6.1.4.1.20044.50.2.1.1.2.1 | Scalarpmc1002AlmConfTableSave | read-only | current | PM Configuration Save :This OID is at 1 during the saving of a new configuration table in the module Flash memory. <Condtype> CONF_TABLE_SAVE <Probcause> other… |
| 1.3.6.1.4.1.20044.50.2.1.1.2.2 | Scalarpmc1002AlmInvUpload | read-only | current | Inventory Upload :This OID is at 1 during the uploading of PM inventory information. <Condtype> INV_UPLOAD <Probcause> other (1) <Alarmtype> other (1) <Polarit… |
| 1.3.6.1.4.1.20044.50.2.1.1.2.3 | Scalarpmc1002AlmConfTableLoad | read-only | current | PM Configuration Load :This OID is at 1 during the loading of configuration tables in the modules RAM. <Condtype> CONF_TABLE_LOAD <Probcause> other (1) <Alarmt… |
| 1.3.6.1.4.1.20044.50.2.1.1.2.4 | Scalarpmc1002AlmCorrelatOff | read-only | current | Not Used :This OID, when set, indicates that alarm correlation is not being performed. <Condtype> CORRELAT_OFF <Probcause> other (1) <Alarmtype> other (1) <Pol… |
| 1.3.6.1.4.1.20044.50.2.1.1.2.5 | Scalarpmc1002AlmMaintenanceOn | read-only | current | Maintenance Mode :This OID indicates that the PM is in maintenance mode. <Help> This alarm indicates that the maintenance mode is enabled on the PM <Condtype> … |
| 1.3.6.1.4.1.20044.50.2.1.2 | Nodepmc1002AlmOtherUrg | |||
| 1.3.6.1.4.1.20044.50.2.1.2.194 | Nodepmc1002AlmmodInitFailLevel2 | |||
| 1.3.6.1.4.1.20044.50.2.1.2.194.1 | Scalarpmc1002AlmLedFail | read-only | current | Led Fail :This OID indicates that Led register has not been correctly initalized <Help> This alarm indicates if the module LEDs are correctly initialized <Cond… |
| 1.3.6.1.4.1.20044.50.2.1.2.194.2 | Scalarpmc1002AlmNextColdBootForced | read-only | current | Next Cold Boot Forced :This OID indicates that the next Reset will be forced Cold <Help> This alarm indicates that the next reset of the module will be forced … |
| 1.3.6.1.4.1.20044.50.2.1.2.194.3 | Scalarpmc1002AlmBootUndone | read-only | current | Boot Undone :This OID indicates that the boot has not been correctly achieved <Help> This alarm indicates if the module has correctly boot <Condtype> BOOT_UNDO… |
| 1.3.6.1.4.1.20044.50.2.1.2.194.4 | Scalarpmc1002AlmResetHwInitFail | read-only | current | Reset HW Init Fail :This OID indicates that the HW intialization has caused unknown intial conditions <Help> This alarm indicates if the HW has been correctly … |
| 1.3.6.1.4.1.20044.50.2.1.2.194.5 | Scalarpmc1002AlmSwInitFail | read-only | current | SW Init Fail :This OID indicates that the SW intialization has caused unknown intial conditions <Help> This alarm indicates if the SW module is correctly initi… |
| 1.3.6.1.4.1.20044.50.2.1.2.195 | Nodepmc1002AlmmodInitFailLevel3 | |||
| 1.3.6.1.4.1.20044.50.2.1.2.195.1 | Scalarpmc1002AlmGwIdentFail | read-only | current | GW Ident Fail :This OID indicates that GW identification has not been read <Help> This alarm indicates if the GW has been correctly identified <Condtype> GW_ID… |
| 1.3.6.1.4.1.20044.50.2.1.2.195.2 | Scalarpmc1002AlmObmTypeReadFail | read-only | current | OBM Type Read Fail :This OID indicates that OBM type has not been recognized <Help> This alarm indicates if the OBM board has been correctly identified <Condty… |
| 1.3.6.1.4.1.20044.50.2.1.2.195.3 | Scalarpmc1002AlmInitModuleFail | read-only | current | Init Module Fail :This OID indicates that the Module has not been correctly initialized <Help> This alarm indicates if the SW module is correctly initialized <… |
| 1.3.6.1.4.1.20044.50.2.1.2.195.5 | Scalarpmc1002AlmXfp1InitFail | read-only | current | XFP1 Init Fail :This OID indicates that the XFP has not been correctly initialized <Help> This alarm indicates if the line transceiver 1 is correctly initializ… |
| 1.3.6.1.4.1.20044.50.2.1.2.195.6 | Scalarpmc1002AlmXfp2InitFail | read-only | current | XFP2 Init Fail :This OID indicates that the XFP has not been correctly initialized <Help> This alarm indicates if the line transceiver 2 is correctly initializ… |
| 1.3.6.1.4.1.20044.50.2.1.2.195.7 | Scalarpmc1002AlmLine1InitFail | read-only | current | Line1 Init Fail :This OID indicates that the Line registersvsubset has not been correctly initialized <Help> This alarm indicates if the line port is correctly… |
| 1.3.6.1.4.1.20044.50.2.1.2.195.9 | Scalarpmc1002AlmClient1InitFail | read-only | current | Client1 Init Fail :This OID indicates that Client 1 registers subset has not been correctly initialized <Help> This alarm indicates if the client port is corre… |
| 1.3.6.1.4.1.20044.50.2.1.3 | Nodepmc1002AlmOtherCrit | |||
| 1.3.6.1.4.1.20044.50.2.1.3.0 | Nodepmc1002AlmsynthAlm0 | |||
| 1.3.6.1.4.1.20044.50.2.1.3.0.9 | Scalarpmc1002AlmModGlobFail | read-only | current | Module Failure :This OID is set on detection of a failure originating from the PM <Condtype> MOD_GLOB_FAIL <Probcause> equipmentMalfunction (16) <Alarmtype> sy… |
| 1.3.6.1.4.1.20044.50.2.1.3.0.15 | Scalarpmc1002AlmDefFuseA | read-only | current | Fuse A Fail :This OID indicates that the fuse of the power input A is in fail condition <Help> Status of the Fuse A <Condtype> DEF_FUSE_A <Probcause> powerProb… |
| 1.3.6.1.4.1.20044.50.2.1.3.0.16 | Scalarpmc1002AlmDefFuseB | read-only | current | Fuse B Fail :This OID indicates that the fuse of the power input B is in fail condition <Help> Status of the Fuse B <Condtype> DEF_FUSE_B <Probcause> powerProb… |
| 1.3.6.1.4.1.20044.50.2.2 | Nodepmc1002AlmClient | |||
| 1.3.6.1.4.1.20044.50.2.2.1 | Nodepmc1002AlmClientNurg | |||
| 1.3.6.1.4.1.20044.50.2.2.1.48 | Tablepmc1002AlmclientXfpWarningsTable | not-accessible | current | List of pmc1002AlmclientXfpWarnings Article |
| 1.3.6.1.4.1.20044.50.2.2.1.48.1 | Rowpmc1002AlmclientXfpWarningsEntry | not-accessible | current | Row definition for the pmc1002AlmclientXfpWarnings table |
| 1.3.6.1.4.1.20044.50.2.2.1.48.1.1 | Columnpmc1002AlmclientXfpWarningsIndex | read-only | current | Index definition for the pmc1002AlmclientXfpWarnings table |
| 1.3.6.1.4.1.20044.50.2.2.1.48.1.2 | Columnpmc1002AlmClientTxPowerLowWarningPortn | read-only | current | Client Optical Tx Pwr Low Warning :Warning indicating that the XFP/OTX transmitter transmitter output power is lower than the threshold value written in the XF… |
| 1.3.6.1.4.1.20044.50.2.2.1.48.1.3 | Columnpmc1002AlmClientTxPowerHighWarningPortn | read-only | current | Client Optical Tx Pwr High Warning :Warning indicating that the XFP/OTX transmitter transmitter output power is higher than the threshold value written in the … |
| 1.3.6.1.4.1.20044.50.2.2.1.48.1.4 | Columnpmc1002AlmClientTxBiasLowWarningPortn | read-only | current | Client Transceiver Bias Low Warning :Warning indicating that the XFP/OTX transmitter laser bias current is lower than the threshold value written in the XFP/OT… |
| 1.3.6.1.4.1.20044.50.2.2.1.48.1.5 | Columnpmc1002AlmClientTxBiasHighWarningPortn | read-only | current | Client Transceiver Bias High Warning :Warning indicating that the XFP/OTX transmitter laser bias current is higher than the threshold value written in the XFP … |
| 1.3.6.1.4.1.20044.50.2.2.1.48.1.8 | Columnpmc1002AlmClientTempLowWarningPortn | read-only | current | Client Transceiver Temp Low Warning :Warning indicating that the XFP/OTX temperature is lower than the threshold value written in the XFP/OTX EEPROM <Condtype>… |
| 1.3.6.1.4.1.20044.50.2.2.1.48.1.9 | Columnpmc1002AlmClientTempHighWarningPortn | read-only | current | Client Transceiver Temp High Warning :Warning indicating that the XFP/OTX temperature is higher than the threshold value written in the XFP EEPROM <Condtype> C… |
| 1.3.6.1.4.1.20044.50.2.2.1.48.1.16 | Columnpmc1002AlmClientRxPowerLowWarningPortn | read-only | current | Client Optical Rx Pwr Low Warning :Warning indicating that the XFP received optical power is lower than the threshold value written in the XFP EEPROM <Condtype… |
| 1.3.6.1.4.1.20044.50.2.2.1.48.1.17 | Columnpmc1002AlmClientRxPowerHighWarningPortn | read-only | current | Client Optical Rx Pwr High Warning :Warning indicating that the XFP received optical power is higher than the threshold value written in the XFP EEPROM <Condty… |
| 1.3.6.1.4.1.20044.50.2.2.2 | Nodepmc1002AlmClientUrg | |||
| 1.3.6.1.4.1.20044.50.2.2.2.32 | Tablepmc1002AlmclientXfpAlarm1Table | not-accessible | current | List of pmc1002AlmclientXfpAlarm1 Article |
| 1.3.6.1.4.1.20044.50.2.2.2.32.1 | Rowpmc1002AlmclientXfpAlarm1Entry | not-accessible | current | Row definition for the pmc1002AlmclientXfpAlarm1 table |
| 1.3.6.1.4.1.20044.50.2.2.2.32.1.1 | Columnpmc1002AlmclientXfpAlarm1Index | read-only | current | Index definition for the pmc1002AlmclientXfpAlarm1 table |
| 1.3.6.1.4.1.20044.50.2.2.2.32.1.2 | Columnpmc1002AlmClientTxPowerLowAlarmPortn | read-only | current | Client Optical Tx Power Low :Alarm indicating that the XFP/OTX transmitter transmitter output power is lower than the threshold value written in the XFP/OTX EE… |
| 1.3.6.1.4.1.20044.50.2.2.2.32.1.3 | Columnpmc1002AlmClientTxPowerHighAlarmPortn | read-only | current | Client Optical Tx Power High :Alarm indicating that the XFP/OTX transmitter transmitter output power is higher than the threshold value written in the XFP EEPR… |
| 1.3.6.1.4.1.20044.50.2.2.2.32.1.4 | Columnpmc1002AlmClientTxBiasLowAlarmPortn | read-only | current | Client Transceiver Bias Low :Alarm indicating that the XFP/OTX transmitter laser bias current is lower than the threshold value written in the XFP/OTX EEPROM <… |
| 1.3.6.1.4.1.20044.50.2.2.2.32.1.5 | Columnpmc1002AlmClientTxBiasHighAlarmPortn | read-only | current | Client Transceiver Bias High :Alarm indicating that the XFP/OTX transmitter laser bias current is higher than the threshold value written in the XFP EEPROM <Co… |
| 1.3.6.1.4.1.20044.50.2.2.2.32.1.8 | Columnpmc1002AlmClientTempLowAlarmPortn | read-only | current | Client Transceiver Temp Low :Alarm indicating that the XFP/OTX temperature is lower than the threshold value written in the XFP/OTX EEPROM <Condtype> CLIENT_TE… |
| 1.3.6.1.4.1.20044.50.2.2.2.32.1.9 | Columnpmc1002AlmClientTempHighAlarmPortn | read-only | current | Client Transceiver Temp High :Alarm indicating that the XFP/OTX temperature is higher than the threshold value written in the XFP EEPROM <Condtype> CLIENT_TEMP… |
| 1.3.6.1.4.1.20044.50.2.2.2.32.1.16 | Columnpmc1002AlmClientRxPowerLowAlarmPortn | read-only | current | Client Optical Rx Power Low :Alarm indicating that the XFP received optical power is lower than the threshold value written in the XFP EEPROM <Condtype> CLIENT… |
| 1.3.6.1.4.1.20044.50.2.2.2.32.1.17 | Columnpmc1002AlmClientRxPowerHighAlarmPortn | read-only | current | Client Optical Rx Power High :Alarm indicating that the XFP received optical power is higher than the threshold value written in the XFP EEPROM <Condtype> CLIE… |
| 1.3.6.1.4.1.20044.50.2.2.2.64 | Tablepmc1002AlmclientXfpSupplyAlarmTable | not-accessible | current | List of pmc1002AlmclientXfpSupplyAlarm Article |
| 1.3.6.1.4.1.20044.50.2.2.2.64.1 | Rowpmc1002AlmclientXfpSupplyAlarmEntry | not-accessible | current | Row definition for the pmc1002AlmclientXfpSupplyAlarm table |
| 1.3.6.1.4.1.20044.50.2.2.2.64.1.1 | Columnpmc1002AlmclientXfpSupplyAlarmIndex | read-only | current | Index definition for the pmc1002AlmclientXfpSupplyAlarm table |
| 1.3.6.1.4.1.20044.50.2.2.2.64.1.2 | Columnpmc1002AlmClientVee5LowAlarmPortn | read-only | current | VEE5 Power Supply Low :Alarm indicating the XFP/OTX VEE5 power supply is lower than the threshold written in the EEPROM <Condtype> CLIENT_VEE5_LOW_ALARM <Probc… |
| 1.3.6.1.4.1.20044.50.2.2.2.64.1.3 | Columnpmc1002AlmClientVee5HighAlarmPortn | read-only | current | VEE5 Power Supply High :Alarm indicating the XFP/OTX VEE5 power supply is higher than the threshold written in the EEPROM <Condtype> CLIENT_VEE5_HIGH_ALARM <Pr… |
| 1.3.6.1.4.1.20044.50.2.2.2.64.1.4 | Columnpmc1002AlmClientVcc2LowAlarmPortn | read-only | current | VCC2 Power Supply Low :Alarm indicating the XFP/OTX VCC2 power supply is lower than the threshold written in the EEPROM <Condtype> CLIENT_VCC2_LOW_ALARM <Probc… |
| 1.3.6.1.4.1.20044.50.2.2.2.64.1.5 | Columnpmc1002AlmClientVcc2HighAlarmPortn | read-only | current | VCC2 Power Supply High :Alarm indicating the XFP/OTX VCC2 power supply is higher than the threshold written in the EEPROM <Condtype> CLIENT_VCC2_HIGH_ALARM <Pr… |
| 1.3.6.1.4.1.20044.50.2.2.2.64.1.6 | Columnpmc1002AlmClientVcc3LowAlarmPortn | read-only | current | VCC3 Power Supply Low :Alarm indicating the XFP/OTX VCC3 power supply is lower than the threshold written in the EEPROM <Condtype> CLIENT_VCC3_LOW_ALARM <Probc… |
| 1.3.6.1.4.1.20044.50.2.2.2.64.1.7 | Columnpmc1002AlmClientVcc3HighAlarmPortn | read-only | current | VCC3 Power Supply High :Alarm indicating the XFP/OTX VCC3 power supply is higher than the threshold written in the EEPROM <Condtype> CLIENT_VCC3_HIGH_ALARM <Pr… |
| 1.3.6.1.4.1.20044.50.2.2.2.64.1.8 | Columnpmc1002AlmClientVcc5LowAlarmPortn | read-only | current | VCC5 Power Supply Low :Alarm indicating the XFP/OTX VCC5 power supply is lower than the threshold written in the EEPROM <Condtype> CLIENT_VCC5_LOW_ALARM <Probc… |
| 1.3.6.1.4.1.20044.50.2.2.2.64.1.9 | Columnpmc1002AlmClientVcc5HighAlarmPortn | read-only | current | VCC5 Power Supply High :Alarm indicating the XFP/OTX VCC5 power supply is higher than the threshold written in the EEPROM <Condtype> CLIENT_VCC5_HIGH_ALARM <Pr… |
| 1.3.6.1.4.1.20044.50.2.2.2.64.1.10 | Columnpmc1002AlmClientVee5LowWarningPortn | read-only | current | VEE5 Power Supply Low Warning :Warning indicating the XFP/OTX VEE5 power supply is lower than the threshold written in the EEPROM <Condtype> CLIENT_VEE5_LOW_WA… |
| 1.3.6.1.4.1.20044.50.2.2.2.64.1.11 | Columnpmc1002AlmClientVee5HighWarningPortn | read-only | current | VEE5 Power Supply High Warning :Warning indicating the XFP/OTX VEE5 power supply is higher than the threshold written in the EEPROM <Condtype> CLIENT_VEE5_HIGH… |
| 1.3.6.1.4.1.20044.50.2.2.2.64.1.12 | Columnpmc1002AlmClientVcc2LowWarningPortn | read-only | current | VCC2 Power Supply Low Warning :Warning indicating the XFP/OTX VCC2 power supply is lower than the threshold written in the EEPROM <Condtype> CLIENT_VCC2_LOW_WA… |
| 1.3.6.1.4.1.20044.50.2.2.2.64.1.13 | Columnpmc1002AlmClientVcc2HighWarningPortn | read-only | current | VCC2 Power Supply High Warning :Warning indicating the XFP/OTX VCC2 power supply is higher than the threshold written in the EEPROM <Condtype> CLIENT_VCC2_HIGH… |
| 1.3.6.1.4.1.20044.50.2.2.2.64.1.14 | Columnpmc1002AlmClientVcc3LowWarningPortn | read-only | current | VCC3 Power Supply Low Warning :Warning indicating the XFP/OTX VCC3 power supply is lower than the threshold written in the EEPROM <Condtype> CLIENT_VCC3_LOW_WA… |
| 1.3.6.1.4.1.20044.50.2.2.2.64.1.15 | Columnpmc1002AlmClientVcc3HighWarningPortn | read-only | current | VCC3 Power Supply High Warning :Warning indicating the XFP/OTX VCC3 power supply is higher than the threshold written in the EEPROM <Condtype> CLIENT_VCC3_HIGH… |
| 1.3.6.1.4.1.20044.50.2.2.2.64.1.16 | Columnpmc1002AlmClientVcc5LowWarningPortn | read-only | current | VCC5 Power Supply Low Warning :Warning indicating the XFP/OTX VCC5 power supply is lower than the threshold written in the EEPROM <Condtype> CLIENT_VCC5_LOW_WA… |
| 1.3.6.1.4.1.20044.50.2.2.2.64.1.17 | Columnpmc1002AlmClientVcc5HighWarningPortn | read-only | current | VCC5 Power Supply High Warning :Warning indicating the XFP/OTX VCC5 power supply is higher than the threshold written in the EEPROM <Condtype> CLIENT_VCC5_HIGH… |
| 1.3.6.1.4.1.20044.50.2.2.3 | Nodepmc1002AlmClientCrit | |||
| 1.3.6.1.4.1.20044.50.2.2.3.8 | Tablepmc1002AlmsynthAlmPortTable | not-accessible | current | List of pmc1002AlmsynthAlmPort Article |
| 1.3.6.1.4.1.20044.50.2.2.3.8.1 | Rowpmc1002AlmsynthAlmPortEntry | not-accessible | current | Row definition for the pmc1002AlmsynthAlmPort table |
| 1.3.6.1.4.1.20044.50.2.2.3.8.1.1 | Columnpmc1002AlmsynthAlmPortIndex | read-only | current | Index definition for the pmc1002AlmsynthAlmPort table |
| 1.3.6.1.4.1.20044.50.2.2.3.8.1.2 | Columnpmc1002AlmClientSfpAbsentPortn | read-only | current | Client Optical Module Absent :This OID indicates that the XFP module is not present in the client port. <Help> This alarm indicates if the client transceiver i… |
| 1.3.6.1.4.1.20044.50.2.2.3.8.1.3 | Columnpmc1002AlmClientDdmAbsentPortn | read-only | current | DDM Supported On Client SFP+ :This OID indicates that the client optical interface (XFP or OTX) is not operational. <Help> This status indicates if the client … |
| 1.3.6.1.4.1.20044.50.2.2.3.8.1.5 | Columnpmc1002AlmClientHwFailPortn | read-only | current | Client HW Fail :This OID indicates a failure on client port, most probably caused by a HW issue. <Condtype> CLIENT_HW_FAIL <Probcause> equipmentMalfunction (16… |
| 1.3.6.1.4.1.20044.50.2.2.3.8.1.6 | Columnpmc1002AlmClientDwLsdPortn | read-only | current | Client Optical Laser Shutdown :This OID indicates the Client XFP transmitter output is ON. <Help> This status indicates if the client transceiver laser is ON o… |
| 1.3.6.1.4.1.20044.50.2.2.3.8.1.7 | Columnpmc1002AlmClientLocalOosPortn | read-only | current | Local Client Port In Service :This OID indicates that the local Client port is In Service (1) or Out of Service (2) <Help> This status indicates if the local c… |
| 1.3.6.1.4.1.20044.50.2.2.3.8.1.9 | Columnpmc1002AlmClientDwCaisPortn | read-only | current | Client AIS Inserted :This OID indicates a CAIS has been inserted on the output client port. <Help> This status indicates if a Client Alarm Indication Signal is… |
| 1.3.6.1.4.1.20044.50.2.2.3.8.1.10 | Columnpmc1002AlmClientSfpDdmWarningPortn | read-only | current | Warning On Client SFP+ DDM :This OID indicates a warning is being received from the Client XFP DDM <Help> This alarm indicates if a DDM Warning has been detect… |
| 1.3.6.1.4.1.20044.50.2.2.3.8.1.11 | Columnpmc1002AlmClientSfpDdmAlmPortn | read-only | current | Alarm On Client SFP+ DDM :This OID indicates an alarm is being received from the Client XFP DDM <Help> This alarm indicates if a DDM Alarm has been detected on… |
| 1.3.6.1.4.1.20044.50.2.2.3.8.1.13 | Columnpmc1002AlmClientFailPortn | read-only | current | Client Access Fail :This OID indicates a failure on the Client port <Condtype> CLIENT_FAIL <Probcause> equipmentMalfunction (16) <Alarmtype> synthesisAlarm (12… |
| 1.3.6.1.4.1.20044.50.2.2.3.8.1.17 | Columnpmc1002AlmClientUpCsfPortn | read-only | current | Client Signal Fail Inserted :This OID indicates a CSF has been inserted in the upstream client port. <Help> This status indicates if a Client Signal Fail is cu… |
| 1.3.6.1.4.1.20044.50.2.2.3.16 | Tablepmc1002AlmclientAccessioAlmTable | not-accessible | current | List of pmc1002AlmclientAccessioAlm Article |
| 1.3.6.1.4.1.20044.50.2.2.3.16.1 | Rowpmc1002AlmclientAccessioAlmEntry | not-accessible | current | Row definition for the pmc1002AlmclientAccessioAlm table |
| 1.3.6.1.4.1.20044.50.2.2.3.16.1.1 | Columnpmc1002AlmclientAccessioAlmIndex | read-only | current | Index definition for the pmc1002AlmclientAccessioAlm table |
| 1.3.6.1.4.1.20044.50.2.2.3.16.1.2 | Columnpmc1002AlmClientDwLasFailPortn | read-only | current | Client XFP Tx Failed :This OID indicates that the transmitter fails for the XFP plugged into the client port (this alarm reports the transmitter failure alarm … |
| 1.3.6.1.4.1.20044.50.2.2.3.16.1.5 | Columnpmc1002AlmClientUpLosPortn | read-only | current | Client Input Loss Of Signal :This OID indicates that no signal is present on the XFP of the client port <Help> This alarm indicates if an optical signal is det… |
| 1.3.6.1.4.1.20044.50.2.2.3.40 | Tablepmc1002AlmclientXfpAlarm2Table | not-accessible | current | List of pmc1002AlmclientXfpAlarm2 Article |
| 1.3.6.1.4.1.20044.50.2.2.3.40.1 | Rowpmc1002AlmclientXfpAlarm2Entry | not-accessible | current | Row definition for the pmc1002AlmclientXfpAlarm2 table |
| 1.3.6.1.4.1.20044.50.2.2.3.40.1.1 | Columnpmc1002AlmclientXfpAlarm2Index | read-only | current | Index definition for the pmc1002AlmclientXfpAlarm2 table |
| 1.3.6.1.4.1.20044.50.2.2.3.40.1.3 | Columnpmc1002AlmClientModNrPortn | read-only | current | Client Optical Module Not Ready :This OID indicates that the module is unable to determine correct data. <Help> This alarm indicates if the Client transceiver … |
| 1.3.6.1.4.1.20044.50.2.2.3.40.1.4 | Columnpmc1002AlmClientRxCdrNotLockedPortn | read-only | current | Client Optical Rx CDR Unlocked :This OID indicates that a loss of lock on the receiving side CDR has been detected <Help> This alarm indicates if the Rx CDR is… |
| 1.3.6.1.4.1.20044.50.2.2.3.40.1.6 | Columnpmc1002AlmClientRxNrPortn | read-only | current | Client Optical Rx Not Ready :This OID indicates that a condition has arisen leading to invalid data on the receiving side. <Help> This alarm indicates if the R… |
| 1.3.6.1.4.1.20044.50.2.2.3.40.1.7 | Columnpmc1002AlmClientTxCdrNotLockedPortn | read-only | current | Client Optical Tx CDR Unlocked :This OID indicates a loss of lock on the transmitting side CDR has been detected. <Help> This alarm indicates if the Tx CDR is … |
| 1.3.6.1.4.1.20044.50.2.2.3.40.1.8 | Columnpmc1002AlmClientTxFaultPortn | read-only | current | Client Optical Tx Failure :This OID indicates a fault condition on the laser detected by the safety syste <Help> This alarm indicates if the laser of the Clien… |
| 1.3.6.1.4.1.20044.50.2.2.3.40.1.9 | Columnpmc1002AlmClientTxNrPortn | read-only | current | Client Optical Tx Not Ready :This OID indicates a condition has arisen leading to invalid data on the transmitting side <Help> This alarm indicates if the Tx p… |
| 1.3.6.1.4.1.20044.50.2.2.3.40.1.15 | Columnpmc1002AlmClientWavelengthUnlockedPortn | read-only | current | Client Optical Tx Wavelength Unlocked :This OID indicates that the wavelength error is exceeding the manufacturer tolerance <Help> This alarm indicates if the … |
| 1.3.6.1.4.1.20044.50.2.2.3.40.1.16 | Columnpmc1002AlmClientTecFaultPortn | read-only | current | Client Optical Tx Temp Regul. Failed :This OID indicates a failure on the TEC module <Help> This alarm indicates if the TEC of the Client transceiver is in fai… |
| 1.3.6.1.4.1.20044.50.2.2.3.40.1.17 | Columnpmc1002AlmClientApdSupplyFaultPortn | read-only | current | Client Rx Photodiode Power Failed :This OID indicates a failure on the APD power supply <Help> This alarm indicates if the APD power supply is in fail conditio… |
| 1.3.6.1.4.1.20044.50.2.2.3.72 | Tablepmc1002AlmclientMapperDeAlmTable | not-accessible | current | List of pmc1002AlmclientMapperDeAlm Article |
| 1.3.6.1.4.1.20044.50.2.2.3.72.1 | Rowpmc1002AlmclientMapperDeAlmEntry | not-accessible | current | Row definition for the pmc1002AlmclientMapperDeAlm table |
| 1.3.6.1.4.1.20044.50.2.2.3.72.1.1 | Columnpmc1002AlmclientMapperDeAlmIndex | read-only | current | Index definition for the pmc1002AlmclientMapperDeAlm table |
| 1.3.6.1.4.1.20044.50.2.2.3.72.1.2 | Columnpmc1002AlmClientUpAccOosPortn | read-only | current | Client Loss Of Synchronisation :This OID indicates the upstream client input port is in Loss of Synchronization <Help> This alarms indicates if the input clien… |
| 1.3.6.1.4.1.20044.50.2.2.3.72.1.11 | Columnpmc1002AlmClientUpBufferOvlPortn | read-only | current | Client Upstream Buffer Overload :This OID indicates that the rate adaptation buffer for client port is in overload. <Condtype> CLIENT_UP_BUFFER_OVL <Probcause>… |
| 1.3.6.1.4.1.20044.50.2.2.3.72.1.12 | Columnpmc1002AlmClientDwCsfDetPortn | read-only | current | Client Signal Fail Detected :This OID indicates that a CSF has been detected on client port in the downstream direction <Help> This alarm indicates if a Client… |
| 1.3.6.1.4.1.20044.50.2.2.3.72.1.15 | Columnpmc1002AlmClientDwBufferOvlPortn | read-only | current | Client Downstream Buffer Overload :This OID indicates that the de-mapper buffer for client port is in overload. <Condtype> CLIENT_DW_BUFFER_OVL <Probcause> equ… |
| 1.3.6.1.4.1.20044.50.2.3 | Nodepmc1002AlmLine | |||
| 1.3.6.1.4.1.20044.50.2.3.1 | Nodepmc1002AlmLineNurg | |||
| 1.3.6.1.4.1.20044.50.2.3.1.209 | Tablepmc1002AlmlineXfp1WarningsTable | not-accessible | current | List of pmc1002AlmlineXfp1Warnings Article |
| 1.3.6.1.4.1.20044.50.2.3.1.209.1 | Rowpmc1002AlmlineXfp1WarningsEntry | not-accessible | current | Row definition for the pmc1002AlmlineXfp1Warnings table |
| 1.3.6.1.4.1.20044.50.2.3.1.209.1.1 | Columnpmc1002AlmlineXfp1WarningsIndex | read-only | current | Index definition for the pmc1002AlmlineXfp1Warnings table |
| 1.3.6.1.4.1.20044.50.2.3.1.209.1.2 | Columnpmc1002AlmLineTxPowerLowWarningPortn | read-only | current | Line Optical Tx Power Low Warning :Warning indicating that the XFP/OTX transmitter transmitter output power is lower than the threshold value written in the XF… |
| 1.3.6.1.4.1.20044.50.2.3.1.209.1.3 | Columnpmc1002AlmLineTxPowerHighWarningPortn | read-only | current | Line Optical Tx Power High Warning :Warning indicating that the XFP/OTX transmitter transmitter output power is higher than the threshold value written in the … |
| 1.3.6.1.4.1.20044.50.2.3.1.209.1.4 | Columnpmc1002AlmLineTxBiasLowWarningPortn | read-only | current | Line Transceiver Bias Low Warning :Warning indicating that the XFP/OTX transmitter laser bias current is lower than the threshold value written in the XFP/OTX … |
| 1.3.6.1.4.1.20044.50.2.3.1.209.1.5 | Columnpmc1002AlmLineTxBiasHighWarningPortn | read-only | current | Line Transceiver Bias High Warning :Warning indicating that the XFP/OTX transmitter laser bias current is higher than the threshold value written in the XFP EE… |
| 1.3.6.1.4.1.20044.50.2.3.1.209.1.8 | Columnpmc1002AlmLineTempLowWarningPortn | read-only | current | Line Transceiver Temp Low Warning :Warning indicating that the XFP/OTX temperature is lower than the threshold value written in the XFP/OTX EEPROM <Condtype> L… |
| 1.3.6.1.4.1.20044.50.2.3.1.209.1.9 | Columnpmc1002AlmLineTempHighWarningPortn | read-only | current | Line Transceiver Temp High Warning :Warning indicating that the XFP/OTX temperature is higher than the threshold value written in the XFP EEPROM <Condtype> LIN… |
| 1.3.6.1.4.1.20044.50.2.3.1.209.1.16 | Columnpmc1002AlmLineRxPowerLowWarningPortn | read-only | current | Line Optical Rx Power Low Warning :Warning indicating that the XFP received optical power is lower than the threshold value written in the XFP EEPROM <Condtype… |
| 1.3.6.1.4.1.20044.50.2.3.1.209.1.17 | Columnpmc1002AlmLineRxPowerHighWarningPortn | read-only | current | Line Optical Rx Power High Warning :Warning indicating that the XFP received optical power is higher than the threshold value written in the XFP EEPROM <Condty… |
| 1.3.6.1.4.1.20044.50.2.3.1.225 | Tablepmc1002AlmlineOtx1TlhWarningsTable | not-accessible | current | List of pmc1002AlmlineOtx1TlhWarnings Article |
| 1.3.6.1.4.1.20044.50.2.3.1.225.1 | Rowpmc1002AlmlineOtx1TlhWarningsEntry | not-accessible | current | Row definition for the pmc1002AlmlineOtx1TlhWarnings table |
| 1.3.6.1.4.1.20044.50.2.3.1.225.1.1 | Columnpmc1002AlmlineOtx1TlhWarningsIndex | read-only | current | Index definition for the pmc1002AlmlineOtx1TlhWarnings table |
| 1.3.6.1.4.1.20044.50.2.3.1.225.1.6 | Columnpmc1002AlmLineModulatorAgingHighWarningPortn | read-only | current | Line Modulator Aging High Warning :Warning indicating the Line OTX TLH modulator aging is higher than the threshold written in the EEPROM <Condtype> LINE_MODUL… |
| 1.3.6.1.4.1.20044.50.2.3.1.225.1.7 | Columnpmc1002AlmLineAgingHighWarningPortn | read-only | current | Line OTX TLH Aging High Warning :Warning indicating the Line OTX TLH aging is higher than the threshold written in the EEPROM <Condtype> LINE_AGING_HIGH_WARNIN… |
| 1.3.6.1.4.1.20044.50.2.3.1.225.1.13 | Columnpmc1002AlmLineFreqDevHighWarningPortn | read-only | current | Line Freq. Deviation High Warning :Warning indicating the Line OTX TLH frequency deviation is higher than the threshold written in the EEPROM <Condtype> LINE_F… |
| 1.3.6.1.4.1.20044.50.2.3.1.225.1.15 | Columnpmc1002AlmLineLaserTempHighWarningPortn | read-only | current | Line Laser Temp. High Warning :Warning indicating the Line OTX TLH laser temperature is higher than the threshold written in the EEPROM <Condtype> LINE_LASER_T… |
| 1.3.6.1.4.1.20044.50.2.3.2 | Nodepmc1002AlmLineUrg | |||
| 1.3.6.1.4.1.20044.50.2.3.2.129 | Tablepmc1002AlmdfrmBerTable | not-accessible | current | List of pmc1002AlmdfrmBer Article |
| 1.3.6.1.4.1.20044.50.2.3.2.129.1 | Rowpmc1002AlmdfrmBerEntry | not-accessible | current | Row definition for the pmc1002AlmdfrmBer table |
| 1.3.6.1.4.1.20044.50.2.3.2.129.1.1 | Columnpmc1002AlmdfrmBerIndex | read-only | current | Index definition for the pmc1002AlmdfrmBer table |
| 1.3.6.1.4.1.20044.50.2.3.2.129.1.2 | Columnpmc1002AlmLineSignalDegradePortn | read-only | current | Custom Line Signal Degrade :This OID indicates that the line input signal is DEGRADE. The assertion hysteresis can customized by the host <Condtype> LINE_SIGNA… |
| 1.3.6.1.4.1.20044.50.2.3.2.129.1.3 | Columnpmc1002AlmLineSignalFailPortn | read-only | current | Custom Line Signal Fail :This OID indicates that the line input signal is FAIL. The assertion hysteresis can be customized by the host <Condtype> LINE_SIGNAL_F… |
| 1.3.6.1.4.1.20044.50.2.3.2.129.1.6 | Columnpmc1002AlmLineDegradePortn | read-only | current | Fixed Line Signal Degrade :This OID indicates that the line input signal is DEGRADE. The assetion hysteresis is fixed to 10-8 (assertion) and 10-9 (de-assertio… |
| 1.3.6.1.4.1.20044.50.2.3.2.208 | Tablepmc1002AlmlineXfp1AlarmTable | not-accessible | current | List of pmc1002AlmlineXfp1Alarm Article |
| 1.3.6.1.4.1.20044.50.2.3.2.208.1 | Rowpmc1002AlmlineXfp1AlarmEntry | not-accessible | current | Row definition for the pmc1002AlmlineXfp1Alarm table |
| 1.3.6.1.4.1.20044.50.2.3.2.208.1.1 | Columnpmc1002AlmlineXfp1AlarmIndex | read-only | current | Index definition for the pmc1002AlmlineXfp1Alarm table |
| 1.3.6.1.4.1.20044.50.2.3.2.208.1.2 | Columnpmc1002AlmLineTxPowerLowAlarmPortn | read-only | current | Line Optical Tx Power Low Alarm :Alarm indicating that the XFP/OTX transmitter transmitter output power is lower than the threshold value written in the XFP/OT… |
| 1.3.6.1.4.1.20044.50.2.3.2.208.1.3 | Columnpmc1002AlmLineTxPowerHighAlarmPortn | read-only | current | Line Optical Tx Power High Alarm :Alarm indicating that the XFP/OTX transmitter transmitter output power is higher than the threshold value written in the XFP … |
| 1.3.6.1.4.1.20044.50.2.3.2.208.1.4 | Columnpmc1002AlmLineTxBiasLowAlarmPortn | read-only | current | Line Transceiver Bias Low Alarm :Alarm indicating that the XFP/OTX transmitter laser bias current is lower than the threshold value written in the XFP/OTX EEPR… |
| 1.3.6.1.4.1.20044.50.2.3.2.208.1.5 | Columnpmc1002AlmLineTxBiasHighAlarmPortn | read-only | current | Line Transceiver Bias High Alarm :Alarm indicating that the XFP/OTX transmitter laser bias current is higher than the threshold value written in the XFP EEPROM… |
| 1.3.6.1.4.1.20044.50.2.3.2.208.1.8 | Columnpmc1002AlmLineTempLowAlarmPortn | read-only | current | Line Transceiver Temp Low Alarm :Alarm indicating that the XFP/OTX temperature is lower than the threshold value written in the XFP/OTX EEPROM <Condtype> LINE_… |
| 1.3.6.1.4.1.20044.50.2.3.2.208.1.9 | Columnpmc1002AlmLineTempHighAlarmPortn | read-only | current | Line Transceiver Temp High Alarm :Alarm indicating that the XFP/OTX temperature is higher than the threshold value written in the XFP EEPROM <Condtype> LINE_TE… |
| 1.3.6.1.4.1.20044.50.2.3.2.208.1.16 | Columnpmc1002AlmLineRxPowerLowAlarmPortn | read-only | current | Line Optical Rx Power Low Alarm :Alarm indicating that the XFP received optical power is lower than the threshold value written in the XFP EEPROM <Condtype> LI… |
| 1.3.6.1.4.1.20044.50.2.3.2.208.1.17 | Columnpmc1002AlmLineRxPowerHighAlarmPortn | read-only | current | Line Optical Rx Power High Alarm :Alarm indicating that the XFP received optical power is higher than the threshold value written in the XFP EEPROM <Condtype> … |
| 1.3.6.1.4.1.20044.50.2.3.2.212 | Tablepmc1002AlmlineXfp1SupplyAlarmTable | not-accessible | current | List of pmc1002AlmlineXfp1SupplyAlarm Article |
| 1.3.6.1.4.1.20044.50.2.3.2.212.1 | Rowpmc1002AlmlineXfp1SupplyAlarmEntry | not-accessible | current | Row definition for the pmc1002AlmlineXfp1SupplyAlarm table |
| 1.3.6.1.4.1.20044.50.2.3.2.212.1.1 | Columnpmc1002AlmlineXfp1SupplyAlarmIndex | read-only | current | Index definition for the pmc1002AlmlineXfp1SupplyAlarm table |
| 1.3.6.1.4.1.20044.50.2.3.2.212.1.2 | Columnpmc1002AlmLineVee5LowAlarmPortn | read-only | current | VEE5 Power Supply Low Alarm :Alarm indicating the XFP/OTX VEE5 power supply is lower than the threshold written in the EEPROM <Condtype> LINE_VEE5_LOW_ALARM <P… |
| 1.3.6.1.4.1.20044.50.2.3.2.212.1.3 | Columnpmc1002AlmLineVee5HighAlarmPortn | read-only | current | VEE5 Power Supply High Alarm :Alarm indicating the XFP/OTX VEE5 power supply is higher than the threshold written in the EEPROM <Condtype> LINE_VEE5_HIGH_ALARM… |
| 1.3.6.1.4.1.20044.50.2.3.2.212.1.4 | Columnpmc1002AlmLineVcc2LowAlarmPortn | read-only | current | VCC2 Power Supply Low Alarm :Alarm indicating the XFP/OTX VCC2 power supply is lower than the threshold written in the EEPROM <Condtype> LINE_VCC2_LOW_ALARM <P… |
| 1.3.6.1.4.1.20044.50.2.3.2.212.1.5 | Columnpmc1002AlmLineVcc2HighAlarmPortn | read-only | current | VCC2 Power Supply High Alarm :Alarm indicating the XFP/OTX VCC2 power supply is higher than the threshold written in the EEPROM <Condtype> LINE_VCC2_HIGH_ALARM… |
| 1.3.6.1.4.1.20044.50.2.3.2.212.1.6 | Columnpmc1002AlmLineVcc3LowAlarmPortn | read-only | current | VCC3 Power Supply Low Alarm :Alarm indicating the XFP/OTX VCC3 power supply is lower than the threshold written in the EEPROM <Condtype> LINE_VCC3_LOW_ALARM <P… |
| 1.3.6.1.4.1.20044.50.2.3.2.212.1.7 | Columnpmc1002AlmLineVcc3HighAlarmPortn | read-only | current | VCC3 Power Supply High Alarm :Alarm indicating the XFP/OTX VCC3 power supply is higher than the threshold written in the EEPROM <Condtype> LINE_VCC3_HIGH_ALARM… |
| 1.3.6.1.4.1.20044.50.2.3.2.212.1.8 | Columnpmc1002AlmLineVcc5LowAlarmPortn | read-only | current | VCC5 Power Supply Low Alarm :Alarm indicating the XFP/OTX VCC5 power supply is lower than the threshold written in the EEPROM <Condtype> LINE_VCC5_LOW_ALARM <P… |
| 1.3.6.1.4.1.20044.50.2.3.2.212.1.9 | Columnpmc1002AlmLineVcc5HighAlarmPortn | read-only | current | VCC5 Power Supply High Alarm :Alarm indicating the XFP/OTX VCC5 power supply is higher than the threshold written in the EEPROM <Condtype> LINE_VCC5_HIGH_ALARM… |
| 1.3.6.1.4.1.20044.50.2.3.2.212.1.10 | Columnpmc1002AlmLineVee5LowLineWarningPortn | read-only | current | VEE5 Power Supply Low Warning :Warning indicating the XFP/OTX VEE5 power supply is lower than the threshold written in the EEPROM <Condtype> LINE_VEE5_LOW_LINE… |
| 1.3.6.1.4.1.20044.50.2.3.2.212.1.11 | Columnpmc1002AlmLineVee5HighWarningPortn | read-only | current | VEE5 Power Supply High Warning :Warning indicating the XFP/OTX VEE5 power supply is higher than the threshold written in the EEPROM <Condtype> LINE_VEE5_HIGH_W… |
| 1.3.6.1.4.1.20044.50.2.3.2.212.1.12 | Columnpmc1002AlmLineVcc2LowWarningPortn | read-only | current | VCC2 Power Supply Low Warning :Warning indicating the XFP/OTX VCC2 power supply is lower than the threshold written in the EEPROM <Condtype> LINE_VCC2_LOW_WARN… |
| 1.3.6.1.4.1.20044.50.2.3.2.212.1.13 | Columnpmc1002AlmLineVcc2HighWarningPortn | read-only | current | VCC2 Power Supply High Warning :Warning indicating the XFP/OTX VCC2 power supply is higher than the threshold written in the EEPROM <Condtype> LINE_VCC2_HIGH_W… |
| 1.3.6.1.4.1.20044.50.2.3.2.212.1.14 | Columnpmc1002AlmLineVcc3LowWarningPortn | read-only | current | VCC3 Power Supply Low Warning :Warning indicating the XFP/OTX VCC3 power supply is lower than the threshold written in the EEPROM <Condtype> LINE_VCC3_LOW_WARN… |
| 1.3.6.1.4.1.20044.50.2.3.2.212.1.15 | Columnpmc1002AlmLineVcc3HighWarningPortn | read-only | current | VCC3 Power Supply High Warning :Warning indicating the XFP/OTX VCC3 power supply is higher than the threshold written in the EEPROM <Condtype> LINE_VCC3_HIGH_W… |
| 1.3.6.1.4.1.20044.50.2.3.2.212.1.16 | Columnpmc1002AlmLineVcc5LowWarningPortn | read-only | current | VCC5 Power Supply Low Warning :Warning indicating the XFP/OTX VCC5 power supply is lower than the threshold written in the EEPROM <Condtype> LINE_VCC5_LOW_WARN… |
| 1.3.6.1.4.1.20044.50.2.3.2.212.1.17 | Columnpmc1002AlmLineVcc5HighWarningPortn | read-only | current | VCC5 Power Supply High Warning :Warning indicating the XFP/OTX VCC5 power supply is higher than the threshold written in the EEPROM <Condtype> LINE_VCC5_HIGH_W… |
| 1.3.6.1.4.1.20044.50.2.3.2.224 | Tablepmc1002AlmlineOtx1TlhAlarmsTable | not-accessible | current | List of pmc1002AlmlineOtx1TlhAlarms Article |
| 1.3.6.1.4.1.20044.50.2.3.2.224.1 | Rowpmc1002AlmlineOtx1TlhAlarmsEntry | not-accessible | current | Row definition for the pmc1002AlmlineOtx1TlhAlarms table |
| 1.3.6.1.4.1.20044.50.2.3.2.224.1.1 | Columnpmc1002AlmlineOtx1TlhAlarmsIndex | read-only | current | Index definition for the pmc1002AlmlineOtx1TlhAlarms table |
| 1.3.6.1.4.1.20044.50.2.3.2.224.1.6 | Columnpmc1002AlmLineModulatorAgingHighAlaPortn | read-only | current | Line Modulator Aging High Alarm :Alarm indicating the Line OTX TLH modulator aging is higher than the threshold written in the EEPROM <Condtype> LINE_MODULATOR… |
| 1.3.6.1.4.1.20044.50.2.3.2.224.1.7 | Columnpmc1002AlmLineAgingHighAlaPortn | read-only | current | Line OTX TLH Aging High Alarm :Alarm indicating the Line OTX TLH aging is higher than the threshold written in the EEPROM <Condtype> LINE_AGING_HIGH_ALA <Probc… |
| 1.3.6.1.4.1.20044.50.2.3.2.224.1.10 | Columnpmc1002AlmLineCdrNotReadyPortn | read-only | current | CDR Not Ready :This OID indicates the Clock Data Recovery unit is not yet initialized <Help> This alarm indicates the Clock Data Recovery unit is not yet initi… |
| 1.3.6.1.4.1.20044.50.2.3.2.224.1.13 | Columnpmc1002AlmLineFreqDevHighAlaPortn | read-only | current | Line Freq. Deviation High Alarm :Alarm indicating the Line OTX TLH frequency deviation is higher than the threshold written in the EEPROM <Condtype> LINE_FREQ_… |
| 1.3.6.1.4.1.20044.50.2.3.2.224.1.15 | Columnpmc1002AlmLineLaserTempHighAlaPortn | read-only | current | Line Laser Temp. High Alarm :Alarm indicating the Line OTX TLH laser temperature is higher than the threshold written in the EEPROM <Condtype> LINE_LASER_TEMP_… |
| 1.3.6.1.4.1.20044.50.2.3.3 | Nodepmc1002AlmLineCrit | |||
| 1.3.6.1.4.1.20044.50.2.3.3.7 | Tablepmc1002AlmsynthAlmLineTable | not-accessible | current | List of pmc1002AlmsynthAlmLine Article |
| 1.3.6.1.4.1.20044.50.2.3.3.7.1 | Rowpmc1002AlmsynthAlmLineEntry | not-accessible | current | Row definition for the pmc1002AlmsynthAlmLine table |
| 1.3.6.1.4.1.20044.50.2.3.3.7.1.1 | Columnpmc1002AlmsynthAlmLineIndex | read-only | current | Index definition for the pmc1002AlmsynthAlmLine table |
| 1.3.6.1.4.1.20044.50.2.3.3.7.1.2 | Columnpmc1002AlmLineXfpAbsentPortn | read-only | current | Line Optical Module Absent :This OID indicates that the line optical interface (XFP or OTX) is not plugged in. <Help> This alarm indicates if the line transcei… |
| 1.3.6.1.4.1.20044.50.2.3.3.7.1.3 | Columnpmc1002AlmLineXfpInitNotComplPortn | read-only | current | Line Optical Module Ready :This OID indicates that the line optical interface (XFP or OTX) is not operational. <Help> This status indicates if the line transce… |
| 1.3.6.1.4.1.20044.50.2.3.3.7.1.5 | Columnpmc1002AlmLineHwFailPortn | read-only | current | Line Port HW Failure :This OID indicates a failure on line port, most probably caused by a HW issue <Condtype> LINE_HW_FAIL <Probcause> equipmentMalfunction (1… |
| 1.3.6.1.4.1.20044.50.2.3.3.7.1.6 | Columnpmc1002AlmLineXfpTxOffPortn | read-only | current | Line Optical Laser Shutdown :This OID indicates the line optical output power is on <Help> This status indicates if the line transceiver laser is ON or OFF <Co… |
| 1.3.6.1.4.1.20044.50.2.3.3.7.1.7 | Columnpmc1002AlmLineLocalOosPortn | read-only | current | Line Port In Service :This OID indicates that the Line port is In Service (1) of Out or Service (2) <Help> This status indicates if the line port is in service… |
| 1.3.6.1.4.1.20044.50.2.3.3.7.1.9 | Columnpmc1002AlmLineUpRdiInsPortn | read-only | current | MS-RDI/L-RDI Inserted On Line :This OID indicates an upstream RDI has been inserted in the outgoing 10 Gb/s signal. <Help> This status indicates if a MS-RDI/L-… |
| 1.3.6.1.4.1.20044.50.2.3.3.7.1.10 | Columnpmc1002AlmLineDdmWarningPortn | read-only | current | Warning On Line Optical Module DDM :This OID indicates a warning is present coming out of Line optical interface DDM <Help> This alarm indicates if a DDM Warni… |
| 1.3.6.1.4.1.20044.50.2.3.3.7.1.11 | Columnpmc1002AlmLineDdmAlmPortn | read-only | current | Alarm On Line Optical Module DDM :This OID indicates an alarm is present coming out of Line optical interface DDM <Help> This alarm indicates if a DDM Alarm ha… |
| 1.3.6.1.4.1.20044.50.2.3.3.7.1.13 | Columnpmc1002AlmLineFailPortn | read-only | current | Line Port Failure :This OID indicates a failure on the line port <Condtype> LINE_FAIL <Probcause> equipmentMalfunction (16) <Alarmtype> synthesisAlarm (12) <Po… |
| 1.3.6.1.4.1.20044.50.2.3.3.7.1.17 | Columnpmc1002AlmLineActivePortn | read-only | current | Line Active :This bit indicates the line #n is active on receive side <Condtype> LINE_ACTIVE <Probcause> informationalStatus(1000) <Alarmtype> other (1) <Polar… |
| 1.3.6.1.4.1.20044.50.2.3.3.128 | Tablepmc1002AlmdfrmAlmTable | not-accessible | current | List of pmc1002AlmdfrmAlm Article |
| 1.3.6.1.4.1.20044.50.2.3.3.128.1 | Rowpmc1002AlmdfrmAlmEntry | not-accessible | current | Row definition for the pmc1002AlmdfrmAlm table |
| 1.3.6.1.4.1.20044.50.2.3.3.128.1.1 | Columnpmc1002AlmdfrmAlmIndex | read-only | current | Index definition for the pmc1002AlmdfrmAlm table |
| 1.3.6.1.4.1.20044.50.2.3.3.128.1.2 | Columnpmc1002AlmLineDwAisDetPortn | read-only | current | MS-AIS/L-AIS Detected On Line Input :This OID indicates that an MS-AIS has been detected on line input signal <Help> This alarm indicates if there is a MS-AIS/… |
| 1.3.6.1.4.1.20044.50.2.3.3.128.1.3 | Columnpmc1002AlmLineDwRdiDetPortn | read-only | current | MS-RDI/L-RDI Detected On Line Input :This OID indicates that an MS-RDI has been detected on line input signal <Help> This alarm indicates if there is a MS-RDI/… |
| 1.3.6.1.4.1.20044.50.2.3.3.128.1.4 | Columnpmc1002AlmLineDwOofPortn | read-only | current | SONET/SDH Line Out Of Frame :This OID indicates that an Out Of Frame has been detected on line input signal <Help> This alarm indicates if a Loss Of Frame is d… |
| 1.3.6.1.4.1.20044.50.2.3.3.128.1.5 | Columnpmc1002AlmLineDwLofPortn | read-only | current | SONET/SDH Line Loss Of Frame :This OID indicates that a Loss Of Frame has been detected on line input signal <Help> This alarm indicates if there is a Loss of … |
| 1.3.6.1.4.1.20044.50.2.3.3.128.1.6 | Columnpmc1002AlmLineFecFailPortn | read-only | current | FEC Decoding Fail :This OID indicates that the FEC decoder is in an overcapacity mode and not able to correct errors <Help> This alarm indicates if the FEC dec… |
| 1.3.6.1.4.1.20044.50.2.3.3.133 | Tablepmc1002AlmlineSyncAlarmsTable | not-accessible | current | List of pmc1002AlmlineSyncAlarms Article |
| 1.3.6.1.4.1.20044.50.2.3.3.133.1 | Rowpmc1002AlmlineSyncAlarmsEntry | not-accessible | current | Row definition for the pmc1002AlmlineSyncAlarms table |
| 1.3.6.1.4.1.20044.50.2.3.3.133.1.1 | Columnpmc1002AlmlineSyncAlarmsIndex | read-only | current | Index definition for the pmc1002AlmlineSyncAlarms table |
| 1.3.6.1.4.1.20044.50.2.3.3.133.1.13 | Columnpmc1002AlmLineDwLockerrPortn | read-only | current | Downstream Clock Lock Error :This OID indicates that the deserializer input 10 Gb/s clock recovery is not locked. <Condtype> LINE_DW_LOCKERR <Probcause> receiv… |
| 1.3.6.1.4.1.20044.50.2.3.3.133.1.14 | Columnpmc1002AlmLineUpLockerrPortn | read-only | current | Upstream Clock Lock Error :This OID indicates that the serializer output 10 Gb/s clock multiplier unit is not locked. <Condtype> LINE_UP_LOCKERR <Probcause> re… |
| 1.3.6.1.4.1.20044.50.2.3.3.133.1.17 | Columnpmc1002AlmLineDwLosPortn | read-only | current | Line Input Loss Of Signal :This OID indicates a loss of signal on the 10 Gb/s input. <Help> This alarm indicates if an optical signal is detected on the line t… |
| 1.3.6.1.4.1.20044.50.2.3.3.211 | Tablepmc1002AlmlineXfp1AlarmsTable | not-accessible | current | List of pmc1002AlmlineXfp1Alarms Article |
| 1.3.6.1.4.1.20044.50.2.3.3.211.1 | Rowpmc1002AlmlineXfp1AlarmsEntry | not-accessible | current | Row definition for the pmc1002AlmlineXfp1Alarms table |
| 1.3.6.1.4.1.20044.50.2.3.3.211.1.1 | Columnpmc1002AlmlineXfp1AlarmsIndex | read-only | current | Index definition for the pmc1002AlmlineXfp1Alarms table |
| 1.3.6.1.4.1.20044.50.2.3.3.211.1.3 | Columnpmc1002AlmLineModNrPortn | read-only | current | Line Optical Module Not Ready :This OID indicates that the module is unable to determine correct data. <Help> This alarm indicates if the line transceiver is r… |
| 1.3.6.1.4.1.20044.50.2.3.3.211.1.4 | Columnpmc1002AlmLineRxCdrNotLockedPortn | read-only | current | Line Optical Rx CDR Unlocked :This OID indicates that a loss of lock on the receiving side CDR has been detected <Help> This alarm indicates if the Rx CDR is l… |
| 1.3.6.1.4.1.20044.50.2.3.3.211.1.6 | Columnpmc1002AlmLineRxNrPortn | read-only | current | Line Optical Rx Not Ready :This OID indicates that a condition has arisen leading to invalid data on the receiving side. <Help> This alarm indicates if the Rx … |
| 1.3.6.1.4.1.20044.50.2.3.3.211.1.7 | Columnpmc1002AlmLineTxCdrNotLockedPortn | read-only | current | Line Optical Tx CDR Unlocked :This OID indicates a loss of lock on the transmitting side CDR has been detected. <Help> This alarm indicates if the Tx CDR is lo… |
| 1.3.6.1.4.1.20044.50.2.3.3.211.1.8 | Columnpmc1002AlmLineTxFaultPortn | read-only | current | Line Optical Tx Failure :This OID indicates a fault condition on the laser detected by the safety syste <Help> This alarm indicates if the laser of the line tr… |
| 1.3.6.1.4.1.20044.50.2.3.3.211.1.9 | Columnpmc1002AlmLineTxNrPortn | read-only | current | Line Optical Tx Not Ready :This OID indicates a condition has arisen leading to invalid data on the transmitting side <Help> This alarm indicates if the Tx par… |
| 1.3.6.1.4.1.20044.50.2.3.3.211.1.11 | Columnpmc1002AlmLineChannelNotAcquiredPortn | read-only | current | DWDM Channel Not Acquired :This OID indicates the transceiver didn't tune the DWDM Channel succesfully. <Help> This status indicates the transceiver has not tu… |
| 1.3.6.1.4.1.20044.50.2.3.3.211.1.15 | Columnpmc1002AlmLineWavelengthUnlockedPortn | read-only | current | Line Optical Tx Wavelength Unlock :This OID indicates that the wavelength error is exceeding the manufacturer tolerance <Help> This alarm indicates if the wave… |
| 1.3.6.1.4.1.20044.50.2.3.3.211.1.16 | Columnpmc1002AlmLineTecFaultPortn | read-only | current | Line Optical Tx Temp Regul. Failed :This OID indicates a failure on the TEC module <Help> This alarm indicates if the TEC of the line transceiver is in fail co… |
| 1.3.6.1.4.1.20044.50.2.3.3.211.1.17 | Columnpmc1002AlmLineApdSupplyFaultPortn | read-only | current | Line Rx Photodiode Power Failed :This OID indicates a failure on the APD power supply <Help> This alarm indicates if the APD power supply is in fail condition … |
| 1.3.6.1.4.1.20044.50.3 | Nodepmc1002measures | |||
| 1.3.6.1.4.1.20044.50.3.1 | Nodepmc1002MesrOther | |||
| 1.3.6.1.4.1.20044.50.3.1.0 | Scalarpmc1002Mesrsynth0 | read-only | deprecated | Not Used :This OID gives the unit used on AUX1 measurement of XFP#1 (Unit = ) |
| 1.3.6.1.4.1.20044.50.3.1.1 | Scalarpmc1002Mesrsynth1 | read-only | deprecated | Not Used :This OID gives the unit used on AUX2 measurement of XFP#1 (Unit = ) |
| 1.3.6.1.4.1.20044.50.3.2 | Nodepmc1002MesrClient | |||
| 1.3.6.1.4.1.20044.50.3.2.16 | Tablepmc1002MesrclientModTempMeasTable | not-accessible | current | List of pmc1002MesrclientModTempMeas Article |
| 1.3.6.1.4.1.20044.50.3.2.16.1 | Rowpmc1002MesrclientModTempMeasEntry | not-accessible | current | Row definition for the pmc1002MesrclientModTempMeas table |
| 1.3.6.1.4.1.20044.50.3.2.16.1.1 | Columnpmc1002MesrclientModTempMeasIndex | read-only | current | Index definition for the pmc1002MesrclientModTempMeas table |
| 1.3.6.1.4.1.20044.50.3.2.16.1.2 | Columnpmc1002MesrclientModTempMeasPortn | read-only | current | Client SFP+ Temperature :This OID gives the temperature value of the XFP plugged in port, read from the DDM (Digital Diagnostic Monitoring) (Temperature = AV/2… |
| 1.3.6.1.4.1.20044.50.3.2.32 | Tablepmc1002MesrclientBiasCurrentMeasTable | not-accessible | current | List of pmc1002MesrclientBiasCurrentMeas Article |
| 1.3.6.1.4.1.20044.50.3.2.32.1 | Rowpmc1002MesrclientBiasCurrentMeasEntry | not-accessible | current | Row definition for the pmc1002MesrclientBiasCurrentMeas table |
| 1.3.6.1.4.1.20044.50.3.2.32.1.1 | Columnpmc1002MesrclientBiasCurrentMeasIndex | read-only | current | Index definition for the pmc1002MesrclientBiasCurrentMeas table |
| 1.3.6.1.4.1.20044.50.3.2.32.1.2 | Columnpmc1002MesrclientBiasCurrentMeasPortn | read-only | current | Client SFP+ Laser Bias :This OID gives the bias value of the XFP plugged into port, read from the DDM (Digital Diagnostic Monitoring) (Bias = AV/500) (Unit = m… |
| 1.3.6.1.4.1.20044.50.3.2.40 | Tablepmc1002MesrclientTxPowerMeasTable | not-accessible | current | List of pmc1002MesrclientTxPowerMeas Article |
| 1.3.6.1.4.1.20044.50.3.2.40.1 | Rowpmc1002MesrclientTxPowerMeasEntry | not-accessible | current | Row definition for the pmc1002MesrclientTxPowerMeas table |
| 1.3.6.1.4.1.20044.50.3.2.40.1.1 | Columnpmc1002MesrclientTxPowerMeasIndex | read-only | current | Index definition for the pmc1002MesrclientTxPowerMeas table |
| 1.3.6.1.4.1.20044.50.3.2.40.1.2 | Columnpmc1002MesrclientTxPowerMeasPortn | read-only | current | Client SFP+ Tx Power :This OID gives the transmit power value of the XFP plugged into port, read from the DDM (Digital Diagnostic Monitoring) (Power = 10*log(A… |
| 1.3.6.1.4.1.20044.50.3.2.48 | Tablepmc1002MesrclientRxPowerMeasTable | not-accessible | current | List of pmc1002MesrclientRxPowerMeas Article |
| 1.3.6.1.4.1.20044.50.3.2.48.1 | Rowpmc1002MesrclientRxPowerMeasEntry | not-accessible | current | Row definition for the pmc1002MesrclientRxPowerMeas table |
| 1.3.6.1.4.1.20044.50.3.2.48.1.1 | Columnpmc1002MesrclientRxPowerMeasIndex | read-only | current | Index definition for the pmc1002MesrclientRxPowerMeas table |
| 1.3.6.1.4.1.20044.50.3.2.48.1.2 | Columnpmc1002MesrclientRxPowerMeasPortn | read-only | current | Client SFP+ Rx Power :This OID gives the receive power value of the XFP plugged into port, read in the DDM (Digital Diagnostic Monitoring) (Power = 10*log(AV)-… |
| 1.3.6.1.4.1.20044.50.3.3 | Nodepmc1002MesrLine | |||
| 1.3.6.1.4.1.20044.50.3.3.208 | Tablepmc1002Mesrline1ModTempMeasTable | not-accessible | current | List of pmc1002Mesrline1ModTempMeas Article |
| 1.3.6.1.4.1.20044.50.3.3.208.1 | Rowpmc1002Mesrline1ModTempMeasEntry | not-accessible | current | Row definition for the pmc1002Mesrline1ModTempMeas table |
| 1.3.6.1.4.1.20044.50.3.3.208.1.1 | Columnpmc1002Mesrline1ModTempMeasIndex | read-only | current | Index definition for the pmc1002Mesrline1ModTempMeas table |
| 1.3.6.1.4.1.20044.50.3.3.208.1.2 | Columnpmc1002Mesrline1ModTempMeasPortn | read-only | current | Line Optical Module Temperature :This OID gives the temperature of the XFP or OTX plugged in line#n, read from the DDM (Digital Diagnostic Monitoring) (Tempera… |
| 1.3.6.1.4.1.20044.50.3.3.209 | Tablepmc1002Mesrline1ReservedTable | not-accessible | deprecated | List of pmc1002Mesrline1Reserved Article |
| 1.3.6.1.4.1.20044.50.3.3.209.1 | Rowpmc1002Mesrline1ReservedEntry | not-accessible | deprecated | Row definition for the pmc1002Mesrline1Reserved table |
| 1.3.6.1.4.1.20044.50.3.3.209.1.1 | Columnpmc1002Mesrline1ReservedIndex | read-only | deprecated | Index definition for the pmc1002Mesrline1Reserved table |
| 1.3.6.1.4.1.20044.50.3.3.209.1.2 | Columnpmc1002Mesrline1ReservedPortn | read-only | deprecated | Not Used :Reserved |
| 1.3.6.1.4.1.20044.50.3.3.210 | Tablepmc1002Mesrline1BiasCurrentMeasTable | not-accessible | current | List of pmc1002Mesrline1BiasCurrentMeas Article |
| 1.3.6.1.4.1.20044.50.3.3.210.1 | Rowpmc1002Mesrline1BiasCurrentMeasEntry | not-accessible | current | Row definition for the pmc1002Mesrline1BiasCurrentMeas table |
| 1.3.6.1.4.1.20044.50.3.3.210.1.1 | Columnpmc1002Mesrline1BiasCurrentMeasIndex | read-only | current | Index definition for the pmc1002Mesrline1BiasCurrentMeas table |
| 1.3.6.1.4.1.20044.50.3.3.210.1.2 | Columnpmc1002Mesrline1BiasCurrentMeasPortn | read-only | current | XFP Or OTX Laser Bias :This OID gives the bias value of the XFP or OTX plugged in line #n, read from the DDM (Digital Diagnostic Monitoring) (Bias = AV/500) (U… |
| 1.3.6.1.4.1.20044.50.3.3.211 | Tablepmc1002Mesrline1TxPowerMeasTable | not-accessible | current | List of pmc1002Mesrline1TxPowerMeas Article |
| 1.3.6.1.4.1.20044.50.3.3.211.1 | Rowpmc1002Mesrline1TxPowerMeasEntry | not-accessible | current | Row definition for the pmc1002Mesrline1TxPowerMeas table |
| 1.3.6.1.4.1.20044.50.3.3.211.1.1 | Columnpmc1002Mesrline1TxPowerMeasIndex | read-only | current | Index definition for the pmc1002Mesrline1TxPowerMeas table |
| 1.3.6.1.4.1.20044.50.3.3.211.1.2 | Columnpmc1002Mesrline1TxPowerMeasPortn | read-only | current | Line Optical Module Tx Power :This OID gives the transmit power value of the XFP or OTX plugged in line #n, read from the DDM (Digital Diagnostic Monitoring) (… |
| 1.3.6.1.4.1.20044.50.3.3.212 | Tablepmc1002Mesrline1RxPowerMeasTable | not-accessible | current | List of pmc1002Mesrline1RxPowerMeas Article |
| 1.3.6.1.4.1.20044.50.3.3.212.1 | Rowpmc1002Mesrline1RxPowerMeasEntry | not-accessible | current | Row definition for the pmc1002Mesrline1RxPowerMeas table |
| 1.3.6.1.4.1.20044.50.3.3.212.1.1 | Columnpmc1002Mesrline1RxPowerMeasIndex | read-only | current | Index definition for the pmc1002Mesrline1RxPowerMeas table |
| 1.3.6.1.4.1.20044.50.3.3.212.1.2 | Columnpmc1002Mesrline1RxPowerMeasPortn | read-only | current | Line Optical Module Rx Power :This OID gives the receive power value of the XFP or OTX plugged in line #n, read from the DDM (Digital Diagnostic Monitoring) (P… |
| 1.3.6.1.4.1.20044.50.3.3.213 | Tablepmc1002Mesrline1Aux1MeasTable | not-accessible | deprecated | List of pmc1002Mesrline1Aux1Meas Article |
| 1.3.6.1.4.1.20044.50.3.3.213.1 | Rowpmc1002Mesrline1Aux1MeasEntry | not-accessible | deprecated | Row definition for the pmc1002Mesrline1Aux1Meas table |
| 1.3.6.1.4.1.20044.50.3.3.213.1.1 | Columnpmc1002Mesrline1Aux1MeasIndex | read-only | deprecated | Index definition for the pmc1002Mesrline1Aux1Meas table |
| 1.3.6.1.4.1.20044.50.3.3.213.1.2 | Columnpmc1002Mesrline1Aux1MeasPortn | read-only | deprecated | Not Used :This OID gives the receive power value read in the DDM (Digital Diagnostic Monitoring) of the XFP or OTX plugged in line #n (Unit = ?) |
| 1.3.6.1.4.1.20044.50.3.3.214 | Tablepmc1002Mesrline1Aux2MeasTable | not-accessible | deprecated | List of pmc1002Mesrline1Aux2Meas Article |
| 1.3.6.1.4.1.20044.50.3.3.214.1 | Rowpmc1002Mesrline1Aux2MeasEntry | not-accessible | deprecated | Row definition for the pmc1002Mesrline1Aux2Meas table |
| 1.3.6.1.4.1.20044.50.3.3.214.1.1 | Columnpmc1002Mesrline1Aux2MeasIndex | read-only | deprecated | Index definition for the pmc1002Mesrline1Aux2Meas table |
| 1.3.6.1.4.1.20044.50.3.3.214.1.2 | Columnpmc1002Mesrline1Aux2MeasPortn | read-only | deprecated | Not Used :This OID gives the receive power value read in the DDM (Digital Diagnostic Monitoring) of the XFP or OTX plugged in line #n (Unit = ?) |
| 1.3.6.1.4.1.20044.50.3.3.224 | Tablepmc1002Mesrline1AgingTable | not-accessible | current | List of pmc1002Mesrline1Aging Article |
| 1.3.6.1.4.1.20044.50.3.3.224.1 | Rowpmc1002Mesrline1AgingEntry | not-accessible | current | Row definition for the pmc1002Mesrline1Aging table |
| 1.3.6.1.4.1.20044.50.3.3.224.1.1 | Columnpmc1002Mesrline1AgingIndex | read-only | current | Index definition for the pmc1002Mesrline1Aging table |
| 1.3.6.1.4.1.20044.50.3.3.224.1.2 | Columnpmc1002Mesrline1AgingPortn | read-only | current | Line OTX TLH Aging :This OID gives the aging of the Line OTX TLH, read from the DDM (Digital Diagnostic Monitoring) (Aging = AV) (Unit = %) <Help> This measure… |
| 1.3.6.1.4.1.20044.50.3.3.225 | Tablepmc1002Mesrline1LaserTemperatureTable | not-accessible | deprecated | List of pmc1002Mesrline1LaserTemperature Article |
| 1.3.6.1.4.1.20044.50.3.3.225.1 | Rowpmc1002Mesrline1LaserTemperatureEntry | not-accessible | deprecated | Row definition for the pmc1002Mesrline1LaserTemperature table |
| 1.3.6.1.4.1.20044.50.3.3.225.1.1 | Columnpmc1002Mesrline1LaserTemperatureIndex | read-only | deprecated | Index definition for the pmc1002Mesrline1LaserTemperature table |
| 1.3.6.1.4.1.20044.50.3.3.225.1.2 | Columnpmc1002Mesrline1LaserTemperaturePortn | read-only | deprecated | Line OTX TLH Laser Temperature :This OID gives the laser temperature of the Line OTX TLH, read from the DDM (Digital Diagnostic Monitoring) (Temperature = AV/2… |
| 1.3.6.1.4.1.20044.50.3.3.226 | Tablepmc1002Mesrline1FreqDeviationTable | not-accessible | current | List of pmc1002Mesrline1FreqDeviation Article |
| 1.3.6.1.4.1.20044.50.3.3.226.1 | Rowpmc1002Mesrline1FreqDeviationEntry | not-accessible | current | Row definition for the pmc1002Mesrline1FreqDeviation table |
| 1.3.6.1.4.1.20044.50.3.3.226.1.1 | Columnpmc1002Mesrline1FreqDeviationIndex | read-only | current | Index definition for the pmc1002Mesrline1FreqDeviation table |
| 1.3.6.1.4.1.20044.50.3.3.226.1.2 | Columnpmc1002Mesrline1FreqDeviationPortn | read-only | current | Line OTX TLH Frequency Deviation :This OID gives the frequency deviation of the Line OTX TLH, read from the DDM (Digital Diagnostic Monitoring) (Deviation = (A… |
| 1.3.6.1.4.1.20044.50.3.3.227 | Tablepmc1002Mesrline1LaserWvlengthTable | not-accessible | current | List of pmc1002Mesrline1LaserWvlength Article |
| 1.3.6.1.4.1.20044.50.3.3.227.1 | Rowpmc1002Mesrline1LaserWvlengthEntry | not-accessible | current | Row definition for the pmc1002Mesrline1LaserWvlength table |
| 1.3.6.1.4.1.20044.50.3.3.227.1.1 | Columnpmc1002Mesrline1LaserWvlengthIndex | read-only | current | Index definition for the pmc1002Mesrline1LaserWvlength table |
| 1.3.6.1.4.1.20044.50.3.3.227.1.2 | Columnpmc1002Mesrline1LaserWvlengthPortn | read-only | current | Line Optical Module Wavelength :This OID gives the laser wavelength of the Line OTX TLH, read from the DDM (Digital Diagnostic Monitoring) (Wavelength=29979245… |
| 1.3.6.1.4.1.20044.50.4 | Nodepmc1002counters | |||
| 1.3.6.1.4.1.20044.50.4.1 | Nodepmc1002CntOther | |||
| 1.3.6.1.4.1.20044.50.4.2 | Nodepmc1002CntClient | |||
| 1.3.6.1.4.1.20044.50.4.2.32 | Tablepmc1002CntclientUpErrCntTable | not-accessible | current | List of pmc1002CntclientUpErrCnt Article |
| 1.3.6.1.4.1.20044.50.4.2.32.1 | Rowpmc1002CntclientUpErrCntEntry | not-accessible | current | Row definition for the pmc1002CntclientUpErrCnt table |
| 1.3.6.1.4.1.20044.50.4.2.32.1.1 | Columnpmc1002CntclientUpErrCntIndex | read-only | current | Index definition for the pmc1002CntclientUpErrCnt table |
| 1.3.6.1.4.1.20044.50.4.2.32.1.2 | Columnpmc1002CntclientUpErrCntValuePortn | read-only | current | Client Input Errors :This counter is increased each time a FCS error is detected in 10GbE mode or a B1 error is detected in OC-192/STM-64 mode on the client in… |
| 1.3.6.1.4.1.20044.50.4.2.32.1.3 | Columnpmc1002CntclientUpErrCntErrorPortn | read-only | current | Client Counter Error :This OID when set indicates the FCS error counter value is invalid on input Port |
| 1.3.6.1.4.1.20044.50.4.2.32.1.4 | Columnpmc1002CntclientUpErrCntOverloadPortn | read-only | current | Client Counter Overload :This OID when set indicates a FCS error counter overload on input Port |
| 1.3.6.1.4.1.20044.50.4.2.40 | Tablepmc1002CntclientUpTimCntTable | not-accessible | current | List of pmc1002CntclientUpTimCnt Article |
| 1.3.6.1.4.1.20044.50.4.2.40.1 | Rowpmc1002CntclientUpTimCntEntry | not-accessible | current | Row definition for the pmc1002CntclientUpTimCnt table |
| 1.3.6.1.4.1.20044.50.4.2.40.1.1 | Columnpmc1002CntclientUpTimCntIndex | read-only | current | Index definition for the pmc1002CntclientUpTimCnt table |
| 1.3.6.1.4.1.20044.50.4.2.40.1.2 | Columnpmc1002CntclientUpTimCntValuePortn | read-only | current | Client Upstream Timer Counter :This is the timing counter dedicated to the upstream access counters. It is incremented every 125 us. |
| 1.3.6.1.4.1.20044.50.4.2.40.1.3 | Columnpmc1002CntclientUpTimCntErrorPortn | read-only | current | Client Counter Error :This OID when set indicates the upstream timing counter value is invalid on Port |
| 1.3.6.1.4.1.20044.50.4.2.40.1.4 | Columnpmc1002CntclientUpTimCntOverloadPortn | read-only | current | Client Counter Overload :This OID when set indicates a upstream timing counter overload on Port |
| 1.3.6.1.4.1.20044.50.4.2.64 | Tablepmc1002CntclientDwErrCntTable | not-accessible | current | List of pmc1002CntclientDwErrCnt Article |
| 1.3.6.1.4.1.20044.50.4.2.64.1 | Rowpmc1002CntclientDwErrCntEntry | not-accessible | current | Row definition for the pmc1002CntclientDwErrCnt table |
| 1.3.6.1.4.1.20044.50.4.2.64.1.1 | Columnpmc1002CntclientDwErrCntIndex | read-only | current | Index definition for the pmc1002CntclientDwErrCnt table |
| 1.3.6.1.4.1.20044.50.4.2.64.1.2 | Columnpmc1002CntclientDwErrCntValuePortn | read-only | current | Client Output Errors :This counter is increased each time a B1/FCS error is detected on the client output stream <Help> This counter gives the number of FCS er… |
| 1.3.6.1.4.1.20044.50.4.2.64.1.3 | Columnpmc1002CntclientDwErrCntErrorPortn | read-only | current | Client Counter Error :This OID when set indicates the FCS error counter value is invalid on output Port |
| 1.3.6.1.4.1.20044.50.4.2.64.1.4 | Columnpmc1002CntclientDwErrCntOverloadPortn | read-only | current | Client Counter Overload :This OID when set indicates a FCS error counter overload on output Port |
| 1.3.6.1.4.1.20044.50.4.2.72 | Tablepmc1002CntclientDwTimCntTable | not-accessible | current | List of pmc1002CntclientDwTimCnt Article |
| 1.3.6.1.4.1.20044.50.4.2.72.1 | Rowpmc1002CntclientDwTimCntEntry | not-accessible | current | Row definition for the pmc1002CntclientDwTimCnt table |
| 1.3.6.1.4.1.20044.50.4.2.72.1.1 | Columnpmc1002CntclientDwTimCntIndex | read-only | current | Index definition for the pmc1002CntclientDwTimCnt table |
| 1.3.6.1.4.1.20044.50.4.2.72.1.2 | Columnpmc1002CntclientDwTimCntValuePortn | read-only | current | Client Downstream Timer Counter :This is the timing counter dedicated to the downstream access counters. It is incremented every 125 us. |
| 1.3.6.1.4.1.20044.50.4.2.72.1.3 | Columnpmc1002CntclientDwTimCntErrorPortn | read-only | current | Client Counter Error :This OID when set indicates the downstream timer counter value is invalid on Port |
| 1.3.6.1.4.1.20044.50.4.2.72.1.4 | Columnpmc1002CntclientDwTimCntOverloadPortn | read-only | current | Client Counter Overload :This OID when set indicates a downstream timer counter overload on Port |
| 1.3.6.1.4.1.20044.50.4.3 | Nodepmc1002CntLine | |||
| 1.3.6.1.4.1.20044.50.4.3.152 | Tablepmc1002CntlineDfrmErrCntTable | not-accessible | current | List of pmc1002CntlineDfrmErrCnt Article |
| 1.3.6.1.4.1.20044.50.4.3.152.1 | Rowpmc1002CntlineDfrmErrCntEntry | not-accessible | current | Row definition for the pmc1002CntlineDfrmErrCnt table |
| 1.3.6.1.4.1.20044.50.4.3.152.1.1 | Columnpmc1002CntlineDfrmErrCntIndex | read-only | current | Index definition for the pmc1002CntlineDfrmErrCnt table |
| 1.3.6.1.4.1.20044.50.4.3.152.1.2 | Columnpmc1002CntlineDfrmErrCntValuePortn | read-only | current | Line Input B1 Errors :This counter is incremented each time a B1 error is detected on the Deframer input stream. <Help> This counter gives the number of B1 err… |
| 1.3.6.1.4.1.20044.50.4.3.152.1.3 | Columnpmc1002CntlineDfrmErrCntErrorPortn | read-only | current | Line Counter Error :This OID when set indicates the B1 error counter value is invalid on Port |
| 1.3.6.1.4.1.20044.50.4.3.152.1.4 | Columnpmc1002CntlineDfrmErrCntOverloadPortn | read-only | current | Line Counter Overload :This OID when set indicates a B1 error counter overload on Port |
| 1.3.6.1.4.1.20044.50.4.3.153 | Tablepmc1002CntlineDfrmTimCntTable | not-accessible | current | List of pmc1002CntlineDfrmTimCnt Article |
| 1.3.6.1.4.1.20044.50.4.3.153.1 | Rowpmc1002CntlineDfrmTimCntEntry | not-accessible | current | Row definition for the pmc1002CntlineDfrmTimCnt table |
| 1.3.6.1.4.1.20044.50.4.3.153.1.1 | Columnpmc1002CntlineDfrmTimCntIndex | read-only | current | Index definition for the pmc1002CntlineDfrmTimCnt table |
| 1.3.6.1.4.1.20044.50.4.3.153.1.2 | Columnpmc1002CntlineDfrmTimCntValuePortn | read-only | current | Line Timer Counter :This is the timing counter dedicated to the downstream deframer counters. It is incremented every 125 us. |
| 1.3.6.1.4.1.20044.50.4.3.153.1.3 | Columnpmc1002CntlineDfrmTimCntErrorPortn | read-only | current | Line Counter Error :This OID when set indicates the deframer timer counter value is invalid on Port |
| 1.3.6.1.4.1.20044.50.4.3.153.1.4 | Columnpmc1002CntlineDfrmTimCntOverloadPortn | read-only | current | Line Counter Overload :This OID when set indicates a deframer timer counter overload on Port |
| 1.3.6.1.4.1.20044.50.4.3.154 | Tablepmc1002CntlineDfrmPrimErrCntTable | not-accessible | current | List of pmc1002CntlineDfrmPrimErrCnt Article |
| 1.3.6.1.4.1.20044.50.4.3.154.1 | Rowpmc1002CntlineDfrmPrimErrCntEntry | not-accessible | current | Row definition for the pmc1002CntlineDfrmPrimErrCnt table |
| 1.3.6.1.4.1.20044.50.4.3.154.1.1 | Columnpmc1002CntlineDfrmPrimErrCntIndex | read-only | current | Index definition for the pmc1002CntlineDfrmPrimErrCnt table |
| 1.3.6.1.4.1.20044.50.4.3.154.1.2 | Columnpmc1002CntlineDfrmPrimErrCntValuePortn | read-only | current | Line Input FEC Corrected Errors :This counter is incremented each time an error is corrected by the Forward Error Correction decoder <Help> This counter gives … |
| 1.3.6.1.4.1.20044.50.4.3.154.1.3 | Columnpmc1002CntlineDfrmPrimErrCntErrorPortn | read-only | current | Line FEC Counter Error :This bit when set indicates the FEC counter value is invalid on Port |
| 1.3.6.1.4.1.20044.50.4.3.154.1.4 | Columnpmc1002CntlineDfrmPrimErrCntOverloadPortn | read-only | current | Line FEC Counter Overload :This bit when set indicates a FEC counter overload on Port |
| 1.3.6.1.4.1.20044.50.4.259 | Scalarpmc1002CntCountersReset | read-write | current | Counters Reset:This OID resets and restarts all the counters |
| 1.3.6.1.4.1.20044.50.4.260 | Scalarpmc1002CntCountersStop | read-write | current | Counters stop:This OID stops all the counters |
| 1.3.6.1.4.1.20044.50.6 | Nodepmc1002controlsWrite | |||
| 1.3.6.1.4.1.20044.50.6.1 | Nodepmc1002CtrlOther | |||
| 1.3.6.1.4.1.20044.50.6.1.1 | Nodepmc1002CtrlconfMgnt1 | |||
| 1.3.6.1.4.1.20044.50.6.1.1.1 | Scalarpmc1002CtrlConf1Load1 | read-write | current | Load Configuration Tables Set Nb 1 :When set this OID enables loading from flash configuration1 into the PM. |
| 1.3.6.1.4.1.20044.50.6.1.1.2 | Scalarpmc1002CtrlConf2Load1 | read-write | current | Load Configuration Tables Set Nb 2 :When set this OID enables loading from flash configuration2 into the PM. |
| 1.3.6.1.4.1.20044.50.6.1.1.10 | Scalarpmc1002CtrlConf2Flash1 | read-write | current | Write Configuration Tables :This OID saves the current configuration of the PM as configuration2 in the flash. <Help> This control saves the customer configura… |
| 1.3.6.1.4.1.20044.50.6.1.1.14 | Scalarpmc1002CtrlConf2Clear1 | read-write | current | Clear Configuration Tables :This OID clears the configuration tables from configuration2 in the flash. <Help> This control restores the default configuration o… |
| 1.3.6.1.4.1.20044.50.6.1.4 | Nodepmc1002Ctrlsynth4 | |||
| 1.3.6.1.4.1.20044.50.6.1.4.1 | Scalarpmc1002CtrlCorrelatOn | read-write | current | Enable Alarm Correlation :This OID enables the alarm correlation in the PM. |
| 1.3.6.1.4.1.20044.50.6.1.4.2 | Scalarpmc1002CtrlCorrelatOff | read-write | current | Disable Alarm Correlation :This OID disables the alarm correlation in the PM. |
| 1.3.6.1.4.1.20044.50.6.1.5 | Nodepmc1002CtrlswMgnt | |||
| 1.3.6.1.4.1.20044.50.6.1.5.2 | Scalarpmc1002CtrlColdReset | read-write | current | PM Cold Reset :This OID, when set, causes a cold reset of the PM. This reset is traffic affecting, and the configuration of PM is reloaded on start-up. <Help> … |
| 1.3.6.1.4.1.20044.50.6.1.5.3 | Scalarpmc1002CtrlWarmReset | read-write | current | PM Warm Reset :This OID, when set, causes a warm reset of the PM. This reset is not traffic affecting, and the configuration of PM remains unchanged. <Help> Th… |
| 1.3.6.1.4.1.20044.50.6.1.5.5 | Scalarpmc1002CtrlLoadSwBank1 | read-write | current | Set Software Nb 1 As Active :This OID, when set, loads the SW from bank1 into the PM. It must be followed by a reset. <Help> This controls selects the first SW… |
| 1.3.6.1.4.1.20044.50.6.1.5.6 | Scalarpmc1002CtrlLoadSwBank2 | read-write | current | Set Software Nb 2 As Active :This OID, when set, loads the SW from bank2 into the PM. It must be followed by a reset. <Help> This controls selects the second S… |
| 1.3.6.1.4.1.20044.50.6.1.6 | Nodepmc1002CtrlgwMgnt | |||
| 1.3.6.1.4.1.20044.50.6.1.6.1 | Scalarpmc1002CtrlCurrentGwReset | read-write | current | Active Gateware Reset :This OID, when set, resets the active gateware. It is traffic affecting. |
| 1.3.6.1.4.1.20044.50.6.1.6.5 | Scalarpmc1002CtrlLoadGwBank1 | read-write | current | Set Gateware Nb 1 As Active :This OID, when set, loads the GW from bank1 (Flash) into the PM. It is followed by an automatic gateware cold reset. <Help> This c… |
| 1.3.6.1.4.1.20044.50.6.1.6.6 | Scalarpmc1002CtrlLoadGwBank2 | read-write | current | Set Gateware Nb 2 As Active :This OID, when set, loads the GW from bank2 (Flash) into the PM. It is followed by an automatic gateware cold reset. |
| 1.3.6.1.4.1.20044.50.6.1.6.7 | Scalarpmc1002CtrlLoadGwBank3 | read-write | current | Set Gateware Nb 3 As Active :This OID, when set, loads the GW from bank3 (Flash) into the PM. It is followed by an automatic gateware cold reset. <Help> This c… |
| 1.3.6.1.4.1.20044.50.6.1.6.8 | Scalarpmc1002CtrlLoadGwBank4 | read-write | current | Set Gateware Nb 4 As Active :This OID, when set, loads the GW from bank4 (Flash) into the PM. It is followed by an automatic gateware cold reset. |
| 1.3.6.1.4.1.20044.50.6.1.192 | Nodepmc1002CtrlledTest | |||
| 1.3.6.1.4.1.20044.50.6.1.192.1 | Scalarpmc1002CtrlGreenLed | read-write | current | Green Leds Test :This OID switches on all the green Leds as a test feature. <Help> This control initiates a test leds turning all the LEDs to green |
| 1.3.6.1.4.1.20044.50.6.1.192.2 | Scalarpmc1002CtrlRedLed | read-write | current | Red Leds Test :This OID switches on all the red Leds as a test feature. <Help> This control initiates a test leds turning all the LEDs to red |
| 1.3.6.1.4.1.20044.50.6.1.192.3 | Scalarpmc1002CtrlLedOff | read-write | current | Leds Off :This OID switches off all the Leds as a test feature. <Help> This control initiates a test leds turning all the LEDs to OFF |
| 1.3.6.1.4.1.20044.50.6.1.193 | Nodepmc1002CtrlmoduleOosMode | |||
| 1.3.6.1.4.1.20044.50.6.1.193.1 | Scalarpmc1002CtrlModuleOosMode | read-write | current | PM Out Of Service :This OID sets the PM1008 Out Of Service <Help> This control defines the service state of the complete module |
| 1.3.6.1.4.1.20044.50.6.1.196 | Scalarpmc1002CtrlmoduleDccMgnt | read-write | current | DCC Mode :This OID defines the DCC mode of the PM (No DCC, Terminal Line 1, Terminal Line 2, Terminal Line 1&2) <Help> This control defines the DCC mode of the… |
| 1.3.6.1.4.1.20044.50.6.1.197 | Nodepmc1002CtrlmaintenanceMode | |||
| 1.3.6.1.4.1.20044.50.6.1.197.1 | Scalarpmc1002CtrlMaintenanceMode | read-write | current | Enable Maintenance :This OID enables the maintenance mode on the PM. <Help> This control enables the maintenance mode on the PM. |
| 1.3.6.1.4.1.20044.50.6.2 | Nodepmc1002CtrlClient | |||
| 1.3.6.1.4.1.20044.50.6.2.16 | Tablepmc1002CtrlaccessLoopTable | not-accessible | current | List of pmc1002CtrlaccessLoop Article |
| 1.3.6.1.4.1.20044.50.6.2.16.1 | Rowpmc1002CtrlaccessLoopEntry | not-accessible | current | Row definition for the pmc1002CtrlaccessLoop table |
| 1.3.6.1.4.1.20044.50.6.2.16.1.1 | Columnpmc1002CtrlaccessLoopIndex | read-only | current | Index definition for the pmc1002CtrlaccessLoop table |
| 1.3.6.1.4.1.20044.50.6.2.16.1.2 | Columnpmc1002CtrlaccessLoopPortn | read-write | current | Client Facility Loopback :This OID operates a Client Facility Loopback, looping client input signal on the client output port. The loop is located on the clien… |
| 1.3.6.1.4.1.20044.50.6.2.18 | Tablepmc1002CtrlportOosModeTable | not-accessible | current | List of pmc1002CtrlportOosMode Article |
| 1.3.6.1.4.1.20044.50.6.2.18.1 | Rowpmc1002CtrlportOosModeEntry | not-accessible | current | Row definition for the pmc1002CtrlportOosMode table |
| 1.3.6.1.4.1.20044.50.6.2.18.1.1 | Columnpmc1002CtrlportOosModeIndex | read-only | current | Index definition for the pmc1002CtrlportOosMode table |
| 1.3.6.1.4.1.20044.50.6.2.18.1.2 | Columnpmc1002CtrlportOosModePortn | read-write | current | Client Port Out Of Service :This OID sets the client port Out Of Service <Help> This controls defines the service state of the client port |
| 1.3.6.1.4.1.20044.50.6.2.20 | Tablepmc1002CtrlsfpOffCtrlTable | not-accessible | current | List of pmc1002CtrlsfpOffCtrl Article |
| 1.3.6.1.4.1.20044.50.6.2.20.1 | Rowpmc1002CtrlsfpOffCtrlEntry | not-accessible | current | Row definition for the pmc1002CtrlsfpOffCtrl table |
| 1.3.6.1.4.1.20044.50.6.2.20.1.1 | Columnpmc1002CtrlsfpOffCtrlIndex | read-only | current | Index definition for the pmc1002CtrlsfpOffCtrl table |
| 1.3.6.1.4.1.20044.50.6.2.20.1.2 | Columnpmc1002CtrlsfpOffCtrlPortn | read-write | current | Client SFP+ Optical Laser OFF :This OID switches off the SFP. <Help> This control defines the laser state of the client transceiver |
| 1.3.6.1.4.1.20044.50.6.2.21 | Tablepmc1002CtrlcsfUpInsTable | not-accessible | current | List of pmc1002CtrlcsfUpIns Article |
| 1.3.6.1.4.1.20044.50.6.2.21.1 | Rowpmc1002CtrlcsfUpInsEntry | not-accessible | current | Row definition for the pmc1002CtrlcsfUpIns table |
| 1.3.6.1.4.1.20044.50.6.2.21.1.1 | Columnpmc1002CtrlcsfUpInsIndex | read-only | current | Index definition for the pmc1002CtrlcsfUpIns table |
| 1.3.6.1.4.1.20044.50.6.2.21.1.2 | Columnpmc1002CtrlcsfUpInsPortn | read-write | current | Client Signal Fail Insertion :This OID, when set, inserts a client signal fail in the upstream client Port. <Help> This control inserts a Client Signal Fail fo… |
| 1.3.6.1.4.1.20044.50.6.2.22 | Tablepmc1002CtrlcaisDwInsTable | not-accessible | current | List of pmc1002CtrlcaisDwIns Article |
| 1.3.6.1.4.1.20044.50.6.2.22.1 | Rowpmc1002CtrlcaisDwInsEntry | not-accessible | current | Row definition for the pmc1002CtrlcaisDwIns table |
| 1.3.6.1.4.1.20044.50.6.2.22.1.1 | Columnpmc1002CtrlcaisDwInsIndex | read-only | current | Index definition for the pmc1002CtrlcaisDwIns table |
| 1.3.6.1.4.1.20044.50.6.2.22.1.2 | Columnpmc1002CtrlcaisDwInsPortn | read-write | current | Client AIS Insertion :This OID, when set, inserts a client AIS on the downstream client Port. <Help> This control inserts a Client AIS for the client port |
| 1.3.6.1.4.1.20044.50.6.2.26 | Tablepmc1002CtrlclientAccessTermLoopTable | not-accessible | current | List of pmc1002CtrlclientAccessTermLoop Article |
| 1.3.6.1.4.1.20044.50.6.2.26.1 | Rowpmc1002CtrlclientAccessTermLoopEntry | not-accessible | current | Row definition for the pmc1002CtrlclientAccessTermLoop table |
| 1.3.6.1.4.1.20044.50.6.2.26.1.1 | Columnpmc1002CtrlclientAccessTermLoopIndex | read-only | current | Index definition for the pmc1002CtrlclientAccessTermLoop table |
| 1.3.6.1.4.1.20044.50.6.2.26.1.2 | Columnpmc1002CtrlclientAccessTermLoopPortn | read-write | current | Client Terminal Loopback :This OID operates a Client Terminal Loopback, looping client input signal on the client output port. The loop is located on the line … |
| 1.3.6.1.4.1.20044.50.6.2.52 | Tablepmc1002CtrlprotocolTable | not-accessible | current | List of pmc1002Ctrlprotocol Article |
| 1.3.6.1.4.1.20044.50.6.2.52.1 | Rowpmc1002CtrlprotocolEntry | not-accessible | current | Row definition for the pmc1002Ctrlprotocol table |
| 1.3.6.1.4.1.20044.50.6.2.52.1.1 | Columnpmc1002CtrlprotocolIndex | read-only | current | Index definition for the pmc1002Ctrlprotocol table |
| 1.3.6.1.4.1.20044.50.6.2.52.1.2 | Columnpmc1002CtrlprotocolPortn | read-write | current | Client Protocol: This OID sets the protocol of the Client port. |
| 1.3.6.1.4.1.20044.50.6.2.271 | Tablepmc1002CtrlclientResetAllCountTable | not-accessible | current | List of pmc1002CtrlclientResetAllCount Article |
| 1.3.6.1.4.1.20044.50.6.2.271.1 | Rowpmc1002CtrlclientResetAllCountEntry | not-accessible | current | Row definition for the pmc1002CtrlclientResetAllCount table |
| 1.3.6.1.4.1.20044.50.6.2.271.1.1 | Columnpmc1002CtrlclientResetAllCountIndex | read-only | current | Index definition for the pmc1002CtrlclientResetAllCount table |
| 1.3.6.1.4.1.20044.50.6.2.271.1.2 | Columnpmc1002CtrlclientResetAllCountsPortn | read-write | current | Client Counters Reset :This OID resets every counter on the client port <Help> This control operates a reset on the statistics current ,previous and history cl… |
| 1.3.6.1.4.1.20044.50.6.3 | Nodepmc1002CtrlLine | |||
| 1.3.6.1.4.1.20044.50.6.3.64 | Tablepmc1002CtrlcommAccessLoopTable | not-accessible | deprecated | List of pmc1002CtrlcommAccessLoop Article |
| 1.3.6.1.4.1.20044.50.6.3.64.1 | Rowpmc1002CtrlcommAccessLoopEntry | not-accessible | deprecated | Row definition for the pmc1002CtrlcommAccessLoop table |
| 1.3.6.1.4.1.20044.50.6.3.64.1.1 | Columnpmc1002CtrlcommAccessLoopIndex | read-only | deprecated | Index definition for the pmc1002CtrlcommAccessLoop table |
| 1.3.6.1.4.1.20044.50.6.3.64.1.2 | Columnpmc1002CtrlcommAccessLoopPortn | read-write | deprecated | PM Full Access Loop Mode :This OID, when set, puts the module in common access loop back, looping the 10 Gb/s output signal on the 10 Gb/s input. |
| 1.3.6.1.4.1.20044.50.6.3.66 | Tablepmc1002CtrllineLoopTable | not-accessible | current | List of pmc1002CtrllineLoop Article |
| 1.3.6.1.4.1.20044.50.6.3.66.1 | Rowpmc1002CtrllineLoopEntry | not-accessible | current | Row definition for the pmc1002CtrllineLoop table |
| 1.3.6.1.4.1.20044.50.6.3.66.1.1 | Columnpmc1002CtrllineLoopIndex | read-only | current | Index definition for the pmc1002CtrllineLoop table |
| 1.3.6.1.4.1.20044.50.6.3.66.1.2 | Columnpmc1002CtrllineLoopPortn | read-write | current | Line Facility Loopback :This OID operates a Line Facility Loopback, looping line input signal on the line output port. The loop is located on the line transcei… |
| 1.3.6.1.4.1.20044.50.6.3.67 | Tablepmc1002CtrlmsAisTable | not-accessible | current | List of pmc1002CtrlmsAis Article |
| 1.3.6.1.4.1.20044.50.6.3.67.1 | Rowpmc1002CtrlmsAisEntry | not-accessible | current | Row definition for the pmc1002CtrlmsAis table |
| 1.3.6.1.4.1.20044.50.6.3.67.1.1 | Columnpmc1002CtrlmsAisIndex | read-only | current | Index definition for the pmc1002CtrlmsAis table |
| 1.3.6.1.4.1.20044.50.6.3.67.1.2 | Columnpmc1002CtrlmsAisPortn | read-write | current | Insert MS-AIS/L-AIS On Line Output :This OID, when set, inserts an MS-AIS/L-AIS in the outgoing STM-64/OC-192 signal. |
| 1.3.6.1.4.1.20044.50.6.3.69 | Tablepmc1002CtrlfecDisableTable | not-accessible | current | List of pmc1002CtrlfecDisable Article |
| 1.3.6.1.4.1.20044.50.6.3.69.1 | Rowpmc1002CtrlfecDisableEntry | not-accessible | current | Row definition for the pmc1002CtrlfecDisable table |
| 1.3.6.1.4.1.20044.50.6.3.69.1.1 | Columnpmc1002CtrlfecDisableIndex | read-only | current | Index definition for the pmc1002CtrlfecDisable table |
| 1.3.6.1.4.1.20044.50.6.3.69.1.2 | Columnpmc1002CtrlfecDisablePortn | read-write | current | FEC Disable :This OID disable the Forward Error Correction decoder on the line receive side <Help> This control disables the Forward Error Correction on the li… |
| 1.3.6.1.4.1.20044.50.6.3.74 | Tablepmc1002CtrllineOosModeTable | not-accessible | current | List of pmc1002CtrllineOosMode Article |
| 1.3.6.1.4.1.20044.50.6.3.74.1 | Rowpmc1002CtrllineOosModeEntry | not-accessible | current | Row definition for the pmc1002CtrllineOosMode table |
| 1.3.6.1.4.1.20044.50.6.3.74.1.1 | Columnpmc1002CtrllineOosModeIndex | read-only | current | Index definition for the pmc1002CtrllineOosMode table |
| 1.3.6.1.4.1.20044.50.6.3.74.1.2 | Columnpmc1002CtrllineOosModePortn | read-write | current | Line Port Out Of Service :This OID sets the line port Out Of Service <Help> This control defines the service state of the line port |
| 1.3.6.1.4.1.20044.50.6.3.208 | Tablepmc1002CtrlxfpOnoffTable | not-accessible | current | List of pmc1002CtrlxfpOnoff Article |
| 1.3.6.1.4.1.20044.50.6.3.208.1 | Rowpmc1002CtrlxfpOnoffEntry | not-accessible | current | Row definition for the pmc1002CtrlxfpOnoff table |
| 1.3.6.1.4.1.20044.50.6.3.208.1.1 | Columnpmc1002CtrlxfpOnoffIndex | read-only | current | Index definition for the pmc1002CtrlxfpOnoff table |
| 1.3.6.1.4.1.20044.50.6.3.208.1.2 | Columnpmc1002CtrlxfpOnoffPortn | read-write | current | XFP/OTX Optical Laser OFF :This OID switches off the XFP or the OTX <Help> This control defines the laser state of the line transceiver |
| 1.3.6.1.4.1.20044.50.6.3.209 | Tablepmc1002CtrlxfpLineLoopTable | not-accessible | current | List of pmc1002CtrlxfpLineLoop Article |
| 1.3.6.1.4.1.20044.50.6.3.209.1 | Rowpmc1002CtrlxfpLineLoopEntry | not-accessible | current | Row definition for the pmc1002CtrlxfpLineLoop table |
| 1.3.6.1.4.1.20044.50.6.3.209.1.1 | Columnpmc1002CtrlxfpLineLoopIndex | read-only | current | Index definition for the pmc1002CtrlxfpLineLoop table |
| 1.3.6.1.4.1.20044.50.6.3.209.1.2 | Columnpmc1002CtrlxfpLineLoopPortn | read-write | current | Line XFP/OTX Loop :This OID operates a line loopback on the line XFP or the OTX <Help> This control defines the line loop back of the line transceiver |
| 1.3.6.1.4.1.20044.50.6.3.210 | Tablepmc1002CtrlxfpLineXfiLoopTable | not-accessible | current | List of pmc1002CtrlxfpLineXfiLoop Article |
| 1.3.6.1.4.1.20044.50.6.3.210.1 | Rowpmc1002CtrlxfpLineXfiLoopEntry | not-accessible | current | Row definition for the pmc1002CtrlxfpLineXfiLoop table |
| 1.3.6.1.4.1.20044.50.6.3.210.1.1 | Columnpmc1002CtrlxfpLineXfiLoopIndex | read-only | current | Index definition for the pmc1002CtrlxfpLineXfiLoop table |
| 1.3.6.1.4.1.20044.50.6.3.210.1.2 | Columnpmc1002CtrlxfpLineXfiLoopPortn | read-write | current | Line XFP/OTX XFI Loop :This OID operates a XFI loopback on the line XFP or the OTX <Help> This control defines the XFI loop back of the line transceiver |
| 1.3.6.1.4.1.20044.50.6.3.212 | Tablepmc1002CtrllineTunableChannelTable | not-accessible | current | List of pmc1002CtrllineTunableChannel Article |
| 1.3.6.1.4.1.20044.50.6.3.212.1 | Rowpmc1002CtrllineTunableChannelEntry | not-accessible | current | Row definition for the pmc1002CtrllineTunableChannel table |
| 1.3.6.1.4.1.20044.50.6.3.212.1.1 | Columnpmc1002CtrllineTunableChannelIndex | read-only | current | Index definition for the pmc1002CtrllineTunableChannel table |
| 1.3.6.1.4.1.20044.50.6.3.212.1.2 | Columnpmc1002CtrllineTunableChannelPortn | read-write | current | ITU Channel :This OID selects the ITU channel of the Line OTX TLH Laser <Help> This control defines the ITU channel of the Line OTX TLH Laser |
| 1.3.6.1.4.1.20044.50.6.3.213 | Tablepmc1002CtrllinePhotodiodeModeTable | not-accessible | current | List of pmc1002CtrllinePhotodiodeMode Article |
| 1.3.6.1.4.1.20044.50.6.3.213.1 | Rowpmc1002CtrllinePhotodiodeModeEntry | not-accessible | current | Row definition for the pmc1002CtrllinePhotodiodeMode table |
| 1.3.6.1.4.1.20044.50.6.3.213.1.1 | Columnpmc1002CtrllinePhotodiodeModeIndex | read-only | current | Index definition for the pmc1002CtrllinePhotodiodeMode table |
| 1.3.6.1.4.1.20044.50.6.3.213.1.2 | Columnpmc1002CtrllinePhotodiodeModePortn | read-write | current | OTX TLH Rx Sens. Mode :This OID defines the Rx sensiblity mode of the Line OTX TLH <Help> This control defines the receiver sensibility mode of the Line OTX TL… |
| 1.3.6.1.4.1.20044.50.6.3.214 | Tablepmc1002CtrllinePhotodiodeValueTable | not-accessible | current | List of pmc1002CtrllinePhotodiodeValue Article |
| 1.3.6.1.4.1.20044.50.6.3.214.1 | Rowpmc1002CtrllinePhotodiodeValueEntry | not-accessible | current | Row definition for the pmc1002CtrllinePhotodiodeValue table |
| 1.3.6.1.4.1.20044.50.6.3.214.1.1 | Columnpmc1002CtrllinePhotodiodeValueIndex | read-only | current | Index definition for the pmc1002CtrllinePhotodiodeValue table |
| 1.3.6.1.4.1.20044.50.6.3.214.1.2 | Columnpmc1002CtrllinePhotodiodeValuePortn | read-write | current | OTX TLH Rx Sensibility :This OID sets the Rx sensibility of the Line OTX TLH (custom mode only) <Help> This control defines the receiver sensibility value (onl… |
| 1.3.6.1.4.1.20044.50.6.3.215 | Tablepmc1002CtrllinePowerLaserTable | not-accessible | current | List of pmc1002CtrllinePowerLaser Article |
| 1.3.6.1.4.1.20044.50.6.3.215.1 | Rowpmc1002CtrllinePowerLaserEntry | not-accessible | current | Row definition for the pmc1002CtrllinePowerLaser table |
| 1.3.6.1.4.1.20044.50.6.3.215.1.1 | Columnpmc1002CtrllinePowerLaserIndex | read-only | current | Index definition for the pmc1002CtrllinePowerLaser table |
| 1.3.6.1.4.1.20044.50.6.3.215.1.2 | Columnpmc1002CtrllinePowerLaserPortn | read-write | current | Laser Output Power [3-5] :This OID sets the output power value on the laser of the Line OTX TLH (AV=Power*10+158) (Unit = dBm) <Help> This control defines the … |
| 1.3.6.1.4.1.20044.50.6.3.216 | Tablepmc1002CtrlotxVlhResetTable | not-accessible | current | List of pmc1002CtrlotxVlhReset Article |
| 1.3.6.1.4.1.20044.50.6.3.216.1 | Rowpmc1002CtrlotxVlhResetEntry | not-accessible | current | Row definition for the pmc1002CtrlotxVlhReset table |
| 1.3.6.1.4.1.20044.50.6.3.216.1.1 | Columnpmc1002CtrlotxVlhResetIndex | read-only | current | Index definition for the pmc1002CtrlotxVlhReset table |
| 1.3.6.1.4.1.20044.50.6.3.216.1.2 | Columnpmc1002CtrlotxVlhResetPortn | read-write | current | OTX-VLH Reset :This OID resets the OTX-VLH module <Help> This control resets the OTX-VLH and its parameters |
| 1.3.6.1.4.1.20044.50.6.3.218 | Tablepmc1002CtrllineLoopTransceiverTable | not-accessible | current | List of pmc1002CtrllineLoopTransceiver Article |
| 1.3.6.1.4.1.20044.50.6.3.218.1 | Rowpmc1002CtrllineLoopTransceiverEntry | not-accessible | current | Row definition for the pmc1002CtrllineLoopTransceiver table |
| 1.3.6.1.4.1.20044.50.6.3.218.1.1 | Columnpmc1002CtrllineLoopTransceiverIndex | read-only | current | Index definition for the pmc1002CtrllineLoopTransceiver table |
| 1.3.6.1.4.1.20044.50.6.3.218.1.2 | Columnpmc1002CtrllineLoopTransceiverPortn | read-write | current | Line Terminal Loopback :This OID operates a Line Terminal Loopback, looping line input signal on the line output port. The loop is located on all client transc… |
| 1.3.6.1.4.1.20044.50.6.3.335 | Tablepmc1002CtrllineResetAllCountTable | not-accessible | current | List of pmc1002CtrllineResetAllCount Article |
| 1.3.6.1.4.1.20044.50.6.3.335.1 | Rowpmc1002CtrllineResetAllCountEntry | not-accessible | current | Row definition for the pmc1002CtrllineResetAllCount table |
| 1.3.6.1.4.1.20044.50.6.3.335.1.1 | Columnpmc1002CtrllineResetAllCountIndex | read-only | current | Index definition for the pmc1002CtrllineResetAllCount table |
| 1.3.6.1.4.1.20044.50.6.3.335.1.2 | Columnpmc1002CtrllineResetAllCountsPortn | read-write | current | Line Counters Reset :This OID resets every counter on the line port <Help> This control operates a reset on the statistics current ,previous and history line p… |
| 1.3.6.1.4.1.20044.50.7 | Nodepmc1002ri | |||
| 1.3.6.1.4.1.20044.50.7.1 | Nodepmc1002riTable | |||
| 1.3.6.1.4.1.20044.50.7.1.1 | Tablepmc1002RinvClientTable | not-accessible | current | List of the Clients on the selected module |
| 1.3.6.1.4.1.20044.50.7.1.1.1 | Rowpmc1002RinvClientEntry | not-accessible | current | Row definition for the Client table |
| 1.3.6.1.4.1.20044.50.7.1.1.1.1 | Columnpmc1002RinvClientIndex | read-only | current | Index for Client table |
| 1.3.6.1.4.1.20044.50.7.1.1.1.2 | Columnpmc1002RinvClient | read-only | current | Inventory for the Client: This OID contains the inventory for the Client Port |
| 1.3.6.1.4.1.20044.50.7.1.2 | Tablepmc1002RinvLineTable | not-accessible | current | List of the Lines on the selected module |
| 1.3.6.1.4.1.20044.50.7.1.2.1 | Rowpmc1002RinvLineEntry | not-accessible | current | Row definition for the Line table |
| 1.3.6.1.4.1.20044.50.7.1.2.1.1 | Columnpmc1002RinvLineIndex | read-only | current | Index for XFP table |
| 1.3.6.1.4.1.20044.50.7.1.2.1.2 | Columnpmc1002RinvxfpLine | read-only | current | Inventory for the Line: This OID contains the inventory for the Line |
| 1.3.6.1.4.1.20044.50.7.2 | Scalarpmc1002RinvReloadInventory | read-write | current | Reload the inventory: This OID triggers an inventory reload. |
| 1.3.6.1.4.1.20044.50.7.3 | Scalarpmc1002RinvHwPlatform | read-only | current | HW platform description: This OID contains the description of the Hardware platform. |
| 1.3.6.1.4.1.20044.50.7.4 | Scalarpmc1002RinvModulePlatform | read-only | current | Module platform description: This OID contains the description of the Module. |
| 1.3.6.1.4.1.20044.50.7.5 | Scalarpmc1002RinvSwPlatform | read-only | current | SW platform description: This OID contains the description of the Software platform. |
| 1.3.6.1.4.1.20044.50.7.6 | Scalarpmc1002RinvGwPlatform | read-only | current | GW platform desciption: This OID contains the description of the Gateware platform. |
| 1.3.6.1.4.1.20044.50.8 | Nodepmc1002download | |||
| 1.3.6.1.4.1.20044.50.8.1 | Nodepmc1002DwlOther | |||
| 1.3.6.1.4.1.20044.50.8.1.0 | Nodepmc1002DwlrestartProcess | |||
| 1.3.6.1.4.1.20044.50.8.1.0.1 | Scalarpmc1002DwlWarmRestartProcessed | read-only | current | Warm Restart :This OID indicates that the module last restart was a Warm RESTART |
| 1.3.6.1.4.1.20044.50.8.1.0.2 | Scalarpmc1002DwlColdRestartProcessed | read-only | current | Cold Restart :This OID indicates that the module last restart was a Cold RESTART |
| 1.3.6.1.4.1.20044.50.8.1.1 | Nodepmc1002DwlswBanksUsed | |||
| 1.3.6.1.4.1.20044.50.8.1.1.1 | Scalarpmc1002DwlSwBank1Used | read-only | current | SW bank 1 active :This OID indicates the module is working on SW bank 1 <Help> This status indicates if the SW bank 1 is active or standby |
| 1.3.6.1.4.1.20044.50.8.1.1.2 | Scalarpmc1002DwlSwBank2Used | read-only | current | SW bank 2 active :This OID indicates the module is working on SW bank 2 <Help> This status indicates if the SW bank 2 is active or standby |
| 1.3.6.1.4.1.20044.50.8.1.1.5 | Scalarpmc1002DwlSwBank1Notempty | read-only | current | SW bank 1 loaded :This OID indicates a software is loaded in SW bank 1 <Help> This status indicates if the SW bank 1 contains SW package |
| 1.3.6.1.4.1.20044.50.8.1.1.6 | Scalarpmc1002DwlSwBank2Notempty | read-only | current | SW bank 2 loaded :This OID indicates a software is loaded in SW bank 2 <Help> This status indicates if the SW bank 2 contains SW package |
| 1.3.6.1.4.1.20044.50.8.1.2 | Nodepmc1002DwlgwBanksUsed | |||
| 1.3.6.1.4.1.20044.50.8.1.2.1 | Scalarpmc1002DwlGwBank1Used | read-only | current | GW bank 1 active :This OID indicates the module is working on GW bank 1 <Help> This status indicates if the GW bank 1 is active or standby |
| 1.3.6.1.4.1.20044.50.8.1.2.2 | Scalarpmc1002DwlGwBank2Used | read-only | deprecated | GW bank 2 active :This OID indicates the module is working on GW bank 2 |
| 1.3.6.1.4.1.20044.50.8.1.2.3 | Scalarpmc1002DwlGwBank3Used | read-only | current | GW bank 3 active :This OID indicates the module is working on GW bank 3 <Help> This status indicates if the GW bank 3 is active or standby |
| 1.3.6.1.4.1.20044.50.8.1.2.4 | Scalarpmc1002DwlGwBank4Used | read-only | deprecated | GW bank 4 active :This OID indicates the module is working on GW bank 4 |
| 1.3.6.1.4.1.20044.50.8.1.2.5 | Scalarpmc1002DwlGwBank1Notempty | read-only | current | GW bank 1 loaded :This OID indicates a gateware is loaded in GW bank 1 <Help> This status indicates if the GW bank 1 contains GW package |
| 1.3.6.1.4.1.20044.50.8.1.2.6 | Scalarpmc1002DwlGwBank2Notempty | read-only | deprecated | GW bank 2 loaded :This OID indicates a gateware is loaded in GW bank 2 |
| 1.3.6.1.4.1.20044.50.8.1.2.7 | Scalarpmc1002DwlGwBank3Notempty | read-only | current | GW bank 3 loaded :This OID indicates a gateware is loaded in GW bank 3 <Help> This status indicates if the GW bank 3 contains GW package |
| 1.3.6.1.4.1.20044.50.8.1.2.8 | Scalarpmc1002DwlGwBank4Notempty | read-only | deprecated | GW bank 4 loaded :This OID indicates a gateware is loaded in GW bank 4 |
| 1.3.6.1.4.1.20044.50.8.2 | Nodepmc1002DwlClient | |||
| 1.3.6.1.4.1.20044.50.8.3 | Nodepmc1002DwlLine | |||
| 1.3.6.1.4.1.20044.50.10 | Nodepmc1002Config | |||
| 1.3.6.1.4.1.20044.50.10.1 | Nodepmc1002CfgAccessCAisCsf | |||
| 1.3.6.1.4.1.20044.50.10.1.1 | Tablepmc1002CfgClientcaiscsfTable | not-accessible | current | List of Article |
| 1.3.6.1.4.1.20044.50.10.1.1.1 | Rowpmc1002CfgClientcaiscsfEntry | not-accessible | current | Row definition for the accessCAisCsf table |
| 1.3.6.1.4.1.20044.50.10.1.1.1.1 | Columnpmc1002CfgClientcaiscsfIndex | read-only | current | Index definition for the clientcaiscsf table |
| 1.3.6.1.4.1.20044.50.10.1.1.1.3 | Columnpmc1002CfgCAisModePortn | read-write | current | CAIS mode on Client Port :This register enables/disables port laser shutdown on CAIS insertion condition |
| 1.3.6.1.4.1.20044.50.10.1.1.1.9 | Columnpmc1002CfgUpAccessioAlmPortn | read-write | current | CSF contributors on Client Port :This register configures the contributors to upstream CSF insertion on the port. |
| 1.3.6.1.4.1.20044.50.10.1.1.1.10 | Columnpmc1002CfgUpMapperDeAlmPortn | read-write | current | CSF contributors on Client Port :This register configures the contributors to upstream CSF insertion on the port. |
| 1.3.6.1.4.1.20044.50.10.1.1.1.17 | Columnpmc1002CfgDownAccessioAlmPortn | read-write | current | CAIS contributors on Client Port :This register configures the contributors to downstream CAIS insertion on port. |
| 1.3.6.1.4.1.20044.50.10.1.1.1.18 | Columnpmc1002CfgDownMapperDeAlmPortn | read-write | current | CAIS contributors on Client Port :This register configures the contributors to downstream CAIS insertion on port. |
| 1.3.6.1.4.1.20044.50.10.1.1.1.19 | Columnpmc1002CfgDownDfrmAlmPortn | read-write | current | CAIS contributors on Client Port :This register configures the contributors to downstream CAIS insertion on port. |
| 1.3.6.1.4.1.20044.50.10.1.1.1.20 | Columnpmc1002CfgDownLineSyncAlarmsPortn | read-write | deprecated | CAIS contributors on Client Port :This register configures the contributors to downstream CAIS insertion on port. |
| 1.3.6.1.4.1.20044.50.10.2 | Nodepmc1002CfgStartup | |||
| 1.3.6.1.4.1.20044.50.10.2.1 | Tablepmc1002CfgClientStartupTable | not-accessible | current | List of Article |
| 1.3.6.1.4.1.20044.50.10.2.1.1 | Rowpmc1002CfgClientStartupEntry | not-accessible | current | Row definition for the startup table |
| 1.3.6.1.4.1.20044.50.10.2.1.1.1 | Columnpmc1002CfgClientStartupIndex | read-only | current | Index definition for the clientStartup table |
| 1.3.6.1.4.1.20044.50.10.2.1.1.3 | Columnpmc1002CfgSystConfPortPortn | read-write | current | Default Settings on Client Port :This register configures the default initialisation settings on the port. |
| 1.3.6.1.4.1.20044.50.10.2.1.1.4 | Columnpmc1002CfgNetConfPortPortn | read-write | current | Default Protocol on Client Port :This register configures the default initialisation protocol on the port. |
| 1.3.6.1.4.1.20044.50.10.2.1.1.6 | Columnpmc1002CfgPortsOptionsPortn | read-write | current | Default Options on Client Port :This register configures the default options on the client port |
| 1.3.6.1.4.1.20044.50.10.2.2 | Nodepmc1002tablelineStartup | |||
| 1.3.6.1.4.1.20044.50.10.2.2.2 | Scalarpmc1002CfgsynthTransLine1 | read-write | current | Default Settings on Line 1 :This register configures the default initialisation settings on Line port 1. |
| 1.3.6.1.4.1.20044.50.10.2.2.3 | Scalarpmc1002CfgnetConfMod | read-write | current | Default Protocol on Module :This register configures the default initialisation protocol on the module. |
| 1.3.6.1.4.1.20044.50.10.2.2.5 | Scalarpmc1002CfglineOptions1 | read-write | current | Default Options on Active Line Port :This register configures the default options on the active line port |
| 1.3.6.1.4.1.20044.50.10.2.2.6 | Scalarpmc1002CfgsystTransLine2 | read-write | current | Default Settings on Line 2 :This register configures the default initialisation settings on Line port 2. |
| 1.3.6.1.4.1.20044.50.10.2.2.7 | Scalarpmc1002CfglineSelection | read-write | current | Default Settings of active line :This register configures the start up active line. |
| 1.3.6.1.4.1.20044.50.10.2.3 | Tablepmc1002CfgXfpTable | not-accessible | current | List of Article |
| 1.3.6.1.4.1.20044.50.10.2.3.1 | Rowpmc1002CfgXfpEntry | not-accessible | current | Row definition for the startup table |
| 1.3.6.1.4.1.20044.50.10.2.3.1.1 | Columnpmc1002CfgXfpIndex | read-only | current | Index definition for the xfp table |
| 1.3.6.1.4.1.20044.50.10.2.3.1.3 | Columnpmc1002CfgSystConfXfpPortn | read-write | current | Default settings on XFP Port :This register configures the default initialisation settings on XFP port. |
| 1.3.6.1.4.1.20044.50.10.2.3.1.4 | Columnpmc1002CfgDataRateConfXfpPortn | read-write | deprecated | :Reserved |
| 1.3.6.1.4.1.20044.50.10.2.4 | Tablepmc1002CfgOtxtlhTable | not-accessible | current | List of Article |
| 1.3.6.1.4.1.20044.50.10.2.4.1 | Rowpmc1002CfgOtxtlhEntry | not-accessible | current | Row definition for the startup table |
| 1.3.6.1.4.1.20044.50.10.2.4.1.1 | Columnpmc1002CfgOtxtlhIndex | read-only | current | Index definition for the otxtlh table |
| 1.3.6.1.4.1.20044.50.10.2.4.1.3 | Columnpmc1002CfgLineOtxMiscPortn | read-write | current | Default Line OTX TLH miscellaneous :This register configures the start-up miscellaneous mode of the Line OTX TLH |
| 1.3.6.1.4.1.20044.50.10.2.4.1.4 | Columnpmc1002CfgLineDitherRatePortn | read-write | current | Default Line OTX TLH FM amplitude :This register configures the start-up width of the frequency modulation of the Line OTX TLH |
| 1.3.6.1.4.1.20044.50.10.2.4.1.5 | Columnpmc1002CfgLineDitherFhzPortn | read-write | current | Default Line OTX TLH FM frequency :This register configures the start-up frequency of the frequency modulation of the Line OTX TLH |
| 1.3.6.1.4.1.20044.50.10.2.4.1.6 | Columnpmc1002CfgLinePwrLaserPortn | read-write | current | Defaut Line OTX TLH output Power :This register configures the start-up output power of the Line OTX TLH (Unit = dBm) |
| 1.3.6.1.4.1.20044.50.10.2.4.1.7 | Columnpmc1002CfgLineFCurrentPortn | read-write | current | Default Line OTX TLH Channel :This register configures the start-up laser channel of the Line OTX TLH |
| 1.3.6.1.4.1.20044.50.10.2.4.1.8 | Columnpmc1002CfgLineGridCurrentPortn | read-write | current | Default Line OTX TLH Grid :This register configures the start-up laser grid of the Line OTX TLH |
| 1.3.6.1.4.1.20044.50.10.2.4.1.9 | Columnpmc1002CfgFPortn | read-write | current | Default Line OTX TLH lowest Freq :This register configures the start-up lowest frequency supported on the Line OTX TLH |
| 1.3.6.1.4.1.20044.50.10.2.4.1.10 | Columnpmc1002CfgReservedPortn | read-write | deprecated | : |
| 1.3.6.1.4.1.20044.50.10.2.4.1.11 | Columnpmc1002CfgLinePhotodiodeModePortn | read-write | current | Default Line OTX TLH APD mode :This register configures the start-up APD mode of the Line OTX TLH |
| 1.3.6.1.4.1.20044.50.10.2.4.1.12 | Columnpmc1002CfgLinePhotodiodeValuePortn | read-write | current | Default Line OTX TLH APD atten. :This register configures the start-up APD attenuation on the Line OTX TLH |
| 1.3.6.1.4.1.20044.50.10.3 | Nodepmc1002CfgLabels | |||
| 1.3.6.1.4.1.20044.50.10.3.1 | Tablepmc1002CfgLabelclientTable | not-accessible | current | List of Article |
| 1.3.6.1.4.1.20044.50.10.3.1.1 | Rowpmc1002CfgLabelclientEntry | not-accessible | current | Row definition for the labels table |
| 1.3.6.1.4.1.20044.50.10.3.1.1.1 | Columnpmc1002CfgLabelclientIndex | read-only | current | Index definition for the labelclient table |
| 1.3.6.1.4.1.20044.50.10.3.1.1.3 | Columnpmc1002CfgLabelclientPortn | read-write | current | Default settings on the label of the Ports :These registers configures the default initialisation settings of the labels of the ports. |
| 1.3.6.1.4.1.20044.50.10.3.2 | Tablepmc1002CfgLabellineTable | not-accessible | current | List of Article |
| 1.3.6.1.4.1.20044.50.10.3.2.1 | Rowpmc1002CfgLabellineEntry | not-accessible | current | Row definition for the labels table |
| 1.3.6.1.4.1.20044.50.10.3.2.1.1 | Columnpmc1002CfgLabellineIndex | read-only | current | Index definition for the labelline table |
| 1.3.6.1.4.1.20044.50.10.3.2.1.3 | Columnpmc1002CfgLabellinePortn | read-write | current | Default settings on the label of the lines :These registers configures the default initialisation settings of the labels of the lines. |
| 1.3.6.1.4.1.20044.50.10.4 | Nodepmc1002CfgOther | |||
| 1.3.6.1.4.1.20044.50.10.4.1 | Nodepmc1002tablemoduleOther | |||
| 1.3.6.1.4.1.20044.50.10.4.1.2 | Scalarpmc1002Cfgmode | read-write | current | Default settings on Module :This register selects the DCC configuration of the PM |
| 1.3.6.1.4.1.20044.50.10.5 | Nodepmc1002CfgStartuptablefive | |||
| 1.3.6.1.4.1.20044.50.10.5.1 | Tablepmc1002CfgOtxtlhcapabilitiesTable | not-accessible | current | List of Article |
| 1.3.6.1.4.1.20044.50.10.5.1.1 | Rowpmc1002CfgOtxtlhcapabilitiesEntry | not-accessible | current | Row definition for the startuptablefive table |
| 1.3.6.1.4.1.20044.50.10.5.1.1.1 | Columnpmc1002CfgOtxtlhcapabilitiesIndex | read-only | current | Index definition for the otxtlhcapabilities table |
| 1.3.6.1.4.1.20044.50.10.5.1.1.3 | Columnpmc1002CfgComponentTypePortn | read-only | current | Component parameters :This OID defines the component parameters |
| 1.3.6.1.4.1.20044.50.10.5.1.1.4 | Columnpmc1002CfgMiscellaneousPortn | read-only | current | Miscellaneous default settings :This OID defines the miscellaneous parameters |
| 1.3.6.1.4.1.20044.50.10.5.1.1.5 | Columnpmc1002CfgFirstChannelPortn | read-only | current | Number of the first channel of the component :This OID defines the first channel number of the PM |
| 1.3.6.1.4.1.20044.50.10.5.1.1.6 | Columnpmc1002CfgLastChannelPortn | read-only | current | Number of the last channel of the component :This OID defines the last channel number of the PM |
| 1.3.6.1.4.1.20044.50.10.5.1.1.7 | Columnpmc1002CfgGridPortn | read-only | current | Grid value of the component :This OID defines the grid of the PM |
| 1.3.6.1.4.1.20044.50.10.257 | Scalarpmc1002CfgWriteConfiguration | read-write | current | Write configuration to module:This OID writes the complete configuration to the module |
| 1.3.6.1.4.1.20044.50.11 | Nodepmc1002traps | |||
| 1.3.6.1.4.1.20044.50.11.1 | Scalarpmc1002trapBoardNumber | read-only | current | Last module which generates a trap |
| 1.3.6.1.4.1.20044.50.11.2 | Scalarpmc1002trapClientNumber | read-only | current | Last module which generates a trap |
| 1.3.6.1.4.1.20044.50.11.3 | Scalarpmc1002trapLineNumber | read-only | current | Last module which generates a trap |
| 1.3.6.1.4.1.20044.50.11.30 | Notificationpmc1002LineTrapNotUrgentGoesOn | current | Not urgent Line default is activated | |
| 1.3.6.1.4.1.20044.50.11.31 | Notificationpmc1002LineTrapNotUrgentGoesOff | current | Not urgent Line default disappeared | |
| 1.3.6.1.4.1.20044.50.11.32 | Notificationpmc1002LineTrapUrgentGoesOn | current | Urgent Line default is activated | |
| 1.3.6.1.4.1.20044.50.11.33 | Notificationpmc1002LineTrapUrgentGoesOff | current | Urgent Line default disappeared | |
| 1.3.6.1.4.1.20044.50.11.34 | Notificationpmc1002LineTrapCritGoesOn | current | Critical Line default is activated | |
| 1.3.6.1.4.1.20044.50.11.35 | Notificationpmc1002LineTrapCritGoesOff | current | Critical Line default disappeared | |
| 1.3.6.1.4.1.20044.50.11.40 | Notificationpmc1002ClientTrapNotUrgentGoesOn | current | Not urgent client default is activated | |
| 1.3.6.1.4.1.20044.50.11.41 | Notificationpmc1002ClientTrapNotUrgentGoesOff | current | Not urgent client default disappeared | |
| 1.3.6.1.4.1.20044.50.11.42 | Notificationpmc1002ClientTrapUrgentGoesOn | current | Urgent client default is activated | |
| 1.3.6.1.4.1.20044.50.11.43 | Notificationpmc1002ClientTrapUrgentGoesOff | current | Urgent client default disappeared | |
| 1.3.6.1.4.1.20044.50.11.44 | Notificationpmc1002ClientTrapCritGoesOn | current | Critical client default is activated | |
| 1.3.6.1.4.1.20044.50.11.45 | Notificationpmc1002ClientTrapCritGoesOff | current | Critical client default disappeared | |
| 1.3.6.1.4.1.20044.50.11.50 | Notificationpmc1002PowerTrapUrgentGoesOn | current | Urgent power supply default is activated | |
| 1.3.6.1.4.1.20044.50.11.51 | Notificationpmc1002PowerTrapUrgentGoesOff | current | Urgent power supply default disappeared | |
| 1.3.6.1.4.1.20044.50.12 | Nodepmc1002Monitoring | |||
| 1.3.6.1.4.1.20044.50.12.1 | Nodepmc1002MonOther | |||
| 1.3.6.1.4.1.20044.50.12.1.1 | Nodepmc1002MonSync | |||
| 1.3.6.1.4.1.20044.50.12.1.1.257 | Scalarpmc1002PerfEnable | read-write | current | Perf. Mon. Enable :This OID enables the Performance Monitoring application |
| 1.3.6.1.4.1.20044.50.12.1.1.259 | Scalarpmc1002Perf15minSync | read-write | current | Perf. Mon. 15-min sync. :This OID must be used in external synchronisation mode only to send a 15-min synchronisation command |
| 1.3.6.1.4.1.20044.50.12.1.1.260 | Scalarpmc1002Perf24hSync | read-write | current | Perf. Mon. 24-hours sync. :This OID must be used in external synchronisation mode only to send a 24-hours synchronisation command |
| 1.3.6.1.4.1.20044.50.12.1.2 | Nodepmc1002MonTimeStamp | |||
| 1.3.6.1.4.1.20044.50.12.1.2.1 | Scalarpmc1002Perf15MinShort | read-write | current | 15-min period is short :This OID indicates that the 15-min period lasts less than 890 seconds |
| 1.3.6.1.4.1.20044.50.12.1.2.2 | Scalarpmc1002Perf15MinLong | read-write | current | 15-min period is long :This OID indicates that the 15-min period lasts more than 910 seconds |
| 1.3.6.1.4.1.20044.50.12.1.2.5 | Scalarpmc1002Perf24HoursShort | read-write | current | 24-hours period is short :This OID indicates that 24-hours period lasts less than 86390 seconds |
| 1.3.6.1.4.1.20044.50.12.1.2.6 | Scalarpmc1002Perf24HoursLong | read-write | current | 24-hours period is long :This OID indicates that 24-hours period lasts more than 86410 seconds |
| 1.3.6.1.4.1.20044.50.12.1.2.7 | Scalarpmc1002PerfCurrent15MinElapsedTime | read-write | current | Current 15min period Elapsed Time :This OID gives the number of seconds elapsed in the current 15-minutes period |
| 1.3.6.1.4.1.20044.50.12.1.2.8 | Scalarpmc1002PerfCurrent24HoursElapsedTime | read-write | current | Current 24hours period Elapsed Time :This OID gives the number of seconds elapsed in the current 24-hours period |
| 1.3.6.1.4.1.20044.50.12.2 | Nodepmc1002MonClient | |||
| 1.3.6.1.4.1.20044.50.12.2.16 | Tablepmc1002PerfTelecomClientCurrent15StatTable | not-accessible | current | List of pmc1002PerfTelecomClientCurrent15Stat Article |
| 1.3.6.1.4.1.20044.50.12.2.16.1 | Rowpmc1002PerfTelecomClientCurrent15StatEntry | not-accessible | current | Row definition for the pmc1002PerfTelecomClientCurrent15Stat table |
| 1.3.6.1.4.1.20044.50.12.2.16.1.1 | Columnpmc1002PerfTelecomClientCurrent15StatIndex | read-only | current | Index definition for the pmc1002PerfTelecomClientCurrent15Stat table |
| 1.3.6.1.4.1.20044.50.12.2.16.1.2 | Columnpmc1002PerfTelecomClientCurrent15StatInvCvPortn | read-only | current | Current 15-min CV counter inv. :This OID indicates that the current 15-min Coding Violation counter is invalid |
| 1.3.6.1.4.1.20044.50.12.2.16.1.3 | Columnpmc1002PerfTelecomClientCurrent15StatCvValuePortn | read-only | current | Current 15-min CV counter :This OID gives the current 15-min Coding Violation counter value |
| 1.3.6.1.4.1.20044.50.12.2.16.1.4 | Columnpmc1002PerfTelecomClientCurrent15StatInvEsPortn | read-only | current | Current 15-min ES counter inv. :This OID indicates that the current 15-min Errored Second counter is invalid |
| 1.3.6.1.4.1.20044.50.12.2.16.1.5 | Columnpmc1002PerfTelecomClientCurrent15StatEsValuePortn | read-only | current | Current 15-min ES counter :This OID gives the current 15-min Errored Second counter value |
| 1.3.6.1.4.1.20044.50.12.2.16.1.6 | Columnpmc1002PerfTelecomClientCurrent15StatInvSesPortn | read-only | current | Current 15-min SES counter inv. :This OID indicates that the current 15-min severely Errored Second counter is invalid |
| 1.3.6.1.4.1.20044.50.12.2.16.1.7 | Columnpmc1002PerfTelecomClientCurrent15StatSesValuePortn | read-only | current | Current 15-min SES counter :This OID gives the current 15-min severely Errored Second counter value |
| 1.3.6.1.4.1.20044.50.12.2.16.1.8 | Columnpmc1002PerfTelecomClientCurrent15StatInvSefsPortn | read-only | current | Current 15-min SEFS counter inv. :This OID indicates that the current 15-min severely Errored Framing Second counter is invalid |
| 1.3.6.1.4.1.20044.50.12.2.16.1.9 | Columnpmc1002PerfTelecomClientCurrent15StatSefsValuePortn | read-only | current | Current 15-min SEFS counter :This OID gives the current 15-min severely Errored Framing Second counter value |
| 1.3.6.1.4.1.20044.50.12.2.16.1.10 | Columnpmc1002PerfTelecomClientCurrent15StatInvUasPortn | read-only | current | Current 15-min UAS counter inv. :This OID indicates that the current 15-min UnAvailable Second counter is invalid |
| 1.3.6.1.4.1.20044.50.12.2.16.1.11 | Columnpmc1002PerfTelecomClientCurrent15StatUasValuePortn | read-only | current | Current 15-min UAS counter :This OID gives the current 15-min UnAvailable Second counter value |
| 1.3.6.1.4.1.20044.50.12.2.24 | Tablepmc1002PerfTelecomClientPast15StatHistoryPort1Table | not-accessible | current | List of pmc1002PerfTelecomClientPast15StatHistory Article |
| 1.3.6.1.4.1.20044.50.12.2.24.1 | Rowpmc1002PerfTelecomClientPast15StatHistoryPort1Entry | not-accessible | current | Row definition for the pmc1002PerfTelecomClientPast15StatHistory table |
| 1.3.6.1.4.1.20044.50.12.2.24.1.1 | Columnpmc1002PerfTelecomClientPast15StatHistoryPort1Index | read-only | current | Index definition for the pmc1002PerfTelecomClientPast15StatHistory table |
| 1.3.6.1.4.1.20044.50.12.2.24.1.2 | Columnpmc1002PerfTelecomClientPast15StatHistoryInvCvPort1 | read-only | current | Previous 15-min CV counter inv. :This OID indicates that the previous 15-min Coding Violation counter is invalid |
| 1.3.6.1.4.1.20044.50.12.2.24.1.3 | Columnpmc1002PerfTelecomClientPast15StatHistoryCvValuePort1 | read-only | current | Previous 15-min CV counter :This OID gives the previous 15-min Coding Violation counter value |
| 1.3.6.1.4.1.20044.50.12.2.24.1.4 | Columnpmc1002PerfTelecomClientPast15StatHistoryInvEsPort1 | read-only | current | Previous 15-min ES counter inv. :This OID indicates that the previous 15-min Errored Second counter is invalid |
| 1.3.6.1.4.1.20044.50.12.2.24.1.5 | Columnpmc1002PerfTelecomClientPast15StatHistoryEsValuePort1 | read-only | current | Previous 15-min ES counter :This OID gives the previous 15-min Errored Second counter value |
| 1.3.6.1.4.1.20044.50.12.2.24.1.6 | Columnpmc1002PerfTelecomClientPast15StatHistoryInvSesPort1 | read-only | current | Previous 15-min SES counter inv. :This OID indicates that the previous 15-min severely Errored Second counter is invalid |
| 1.3.6.1.4.1.20044.50.12.2.24.1.7 | Columnpmc1002PerfTelecomClientPast15StatHistorySesValuePort1 | read-only | current | Previous 15-min SES counter :This OID gives the previous 15-min severely Errored Second counter value |
| 1.3.6.1.4.1.20044.50.12.2.24.1.8 | Columnpmc1002PerfTelecomClientPast15StatHistoryInvSefsPort1 | read-only | current | Previous 15-min SEFS counter inv. :This OID indicates that the previous 15-min severely Errored Framing Second counter is invalid |
| 1.3.6.1.4.1.20044.50.12.2.24.1.9 | Columnpmc1002PerfTelecomClientPast15StatHistorySefsValuePort1 | read-only | current | Previous 15-min SEFS counter :This OID gives the previous 15-min severely Errored Framing Second counter value |
| 1.3.6.1.4.1.20044.50.12.2.24.1.10 | Columnpmc1002PerfTelecomClientPast15StatHistoryInvUasPort1 | read-only | current | Previous 15-min UAS counter inv. :This OID indicates that the previous 15-min UnAvailable Second counter is invalid |
| 1.3.6.1.4.1.20044.50.12.2.24.1.11 | Columnpmc1002PerfTelecomClientPast15StatHistoryUasValuePort1 | read-only | current | Previous 15-min UAS counter :This OID gives the previous 15-min UnAvailable Second counter value |
| 1.3.6.1.4.1.20044.50.12.2.32 | Tablepmc1002PerfTelecomClientCurrent24StatTable | not-accessible | current | List of pmc1002PerfTelecomClientCurrent24Stat Article |
| 1.3.6.1.4.1.20044.50.12.2.32.1 | Rowpmc1002PerfTelecomClientCurrent24StatEntry | not-accessible | current | Row definition for the pmc1002PerfTelecomClientCurrent24Stat table |
| 1.3.6.1.4.1.20044.50.12.2.32.1.1 | Columnpmc1002PerfTelecomClientCurrent24StatIndex | read-only | current | Index definition for the pmc1002PerfTelecomClientCurrent24Stat table |
| 1.3.6.1.4.1.20044.50.12.2.32.1.2 | Columnpmc1002PerfTelecomClientCurrent24StatInvCvPortn | read-only | current | Current 24-hours CV counter inv. :This OID indicates that the current 24-hours Coding Violation counter is invalid |
| 1.3.6.1.4.1.20044.50.12.2.32.1.3 | Columnpmc1002PerfTelecomClientCurrent24StatCvValuePortn | read-only | current | Current 24-hours CV counter :This OID gives the current 24-hours Coding Violation counter value |
| 1.3.6.1.4.1.20044.50.12.2.32.1.4 | Columnpmc1002PerfTelecomClientCurrent24StatInvEsPortn | read-only | current | Current 24-hours ES counter inv. :This OID indicates that the current 24-hours Errored Second counter is invalid |
| 1.3.6.1.4.1.20044.50.12.2.32.1.5 | Columnpmc1002PerfTelecomClientCurrent24StatEsValuePortn | read-only | current | Current 24-hours ES counter :This OID gives the current 24-hours Errored Second counter value |
| 1.3.6.1.4.1.20044.50.12.2.32.1.6 | Columnpmc1002PerfTelecomClientCurrent24StatInvSesPortn | read-only | current | Current 24-hours SES counter inv. :This OID indicates that the current 24-hours severely Errored Second counter is invalid |
| 1.3.6.1.4.1.20044.50.12.2.32.1.7 | Columnpmc1002PerfTelecomClientCurrent24StatSesValuePortn | read-only | current | Current 24-hours SES counter :This OID gives the current 24-hours severely Errored Second counter value |
| 1.3.6.1.4.1.20044.50.12.2.32.1.8 | Columnpmc1002PerfTelecomClientCurrent24StatInvSefsPortn | read-only | current | Current 24-hours SEFS counter inv. :This OID indicates that the current 24-hours severely Errored Framing Second counter is invalid |
| 1.3.6.1.4.1.20044.50.12.2.32.1.9 | Columnpmc1002PerfTelecomClientCurrent24StatSefsValuePortn | read-only | current | Current 24-hours SEFS counter :This OID gives the current 24-hours severely Errored Framing Second counter value |
| 1.3.6.1.4.1.20044.50.12.2.32.1.10 | Columnpmc1002PerfTelecomClientCurrent24StatInvUasPortn | read-only | current | Current 24-hours UAS counter inv. :This OID indicates that the current 24-hours UnAvailable Second counter is invalid |
| 1.3.6.1.4.1.20044.50.12.2.32.1.11 | Columnpmc1002PerfTelecomClientCurrent24StatUasValuePortn | read-only | current | Current 24-hours UAS counter :This OID gives the current 24-hours UnAvailable Second counter value |
| 1.3.6.1.4.1.20044.50.12.2.40 | Tablepmc1002PerfTelecomClientPast24StatHistoryPort1Table | not-accessible | current | List of pmc1002PerfTelecomClientPast24StatHistory Article |
| 1.3.6.1.4.1.20044.50.12.2.40.1 | Rowpmc1002PerfTelecomClientPast24StatHistoryPort1Entry | not-accessible | current | Row definition for the pmc1002PerfTelecomClientPast24StatHistory table |
| 1.3.6.1.4.1.20044.50.12.2.40.1.1 | Columnpmc1002PerfTelecomClientPast24StatHistoryPort1Index | read-only | current | Index definition for the pmc1002PerfTelecomClientPast24StatHistory table |
| 1.3.6.1.4.1.20044.50.12.2.40.1.2 | Columnpmc1002PerfTelecomClientPast24StatHistoryInvCvPort1 | read-only | current | Previous 24-hours CV counter inv. :This OID indicates that the previous 24-hours Coding Violation counter is invalid |
| 1.3.6.1.4.1.20044.50.12.2.40.1.3 | Columnpmc1002PerfTelecomClientPast24StatHistoryCvValuePort1 | read-only | current | Previous 24-hours CV counter :This OID gives the previous 24-hours Coding Violation counter value |
| 1.3.6.1.4.1.20044.50.12.2.40.1.4 | Columnpmc1002PerfTelecomClientPast24StatHistoryInvEsPort1 | read-only | current | Previous 24-hours ES counter inv. :This OID indicates that the previous 24-hours Errored Second counter is invalid |
| 1.3.6.1.4.1.20044.50.12.2.40.1.5 | Columnpmc1002PerfTelecomClientPast24StatHistoryEsValuePort1 | read-only | current | Previous 24-hours ES counter :This OID gives the previous 24-hours Errored Second counter value |
| 1.3.6.1.4.1.20044.50.12.2.40.1.6 | Columnpmc1002PerfTelecomClientPast24StatHistoryInvSesPort1 | read-only | current | Previous 24-hours SES counter inv. :This OID indicates that the previous 24-hours severely Errored Second counter is invalid |
| 1.3.6.1.4.1.20044.50.12.2.40.1.7 | Columnpmc1002PerfTelecomClientPast24StatHistorySesValuePort1 | read-only | current | Previous 24-hours SES counter :This OID gives the previous 24-hours severely Errored Second counter value |
| 1.3.6.1.4.1.20044.50.12.2.40.1.8 | Columnpmc1002PerfTelecomClientPast24StatHistoryInvSefsPort1 | read-only | current | Previous 24-hours SEFS counter inv. :This OID indicates that the previous 24-hours severely Errored Framing Second counter is invalid |
| 1.3.6.1.4.1.20044.50.12.2.40.1.9 | Columnpmc1002PerfTelecomClientPast24StatHistorySefsValuePort1 | read-only | current | Previous 24-hours SEFS counter :This OID gives the previous 24-hours severely Errored Framing Second counter value |
| 1.3.6.1.4.1.20044.50.12.2.40.1.10 | Columnpmc1002PerfTelecomClientPast24StatHistoryInvUasPort1 | read-only | current | Previous 24-hours UAS counter inv. :This OID indicates that the previous 24-hours UnAvailable Second counter is invalid |
| 1.3.6.1.4.1.20044.50.12.2.40.1.11 | Columnpmc1002PerfTelecomClientPast24StatHistoryUasValuePort1 | read-only | current | Previous 24-hours UAS counter :This OID gives the previous 24-hours UnAvailable Second counter value |
| 1.3.6.1.4.1.20044.50.12.2.256 | Tablepmc1002PerfDatacomClientCurrent15StatTable | not-accessible | current | List of pmc1002PerfDatacomClientCurrent15Stat Article |
| 1.3.6.1.4.1.20044.50.12.2.256.1 | Rowpmc1002PerfDatacomClientCurrent15StatEntry | not-accessible | current | Row definition for the pmc1002PerfDatacomClientCurrent15Stat table |
| 1.3.6.1.4.1.20044.50.12.2.256.1.1 | Columnpmc1002PerfDatacomClientCurrent15StatIndex | read-only | current | Index definition for the pmc1002PerfDatacomClientCurrent15Stat table |
| 1.3.6.1.4.1.20044.50.12.2.256.1.2 | Columnpmc1002perfdatacomclientCurrent15StatInBytesCountInvPortn | read-only | current | Client Current 15-min Input Bytes counter inv. :This OID indicates that the current 15-min Bytes counter is invalid |
| 1.3.6.1.4.1.20044.50.12.2.256.1.3 | Columnpmc1002perfdatacomclientCurrent15StatInBytesCountPortn | read-only | current | Client Current 15-min Input Bytes counter :This OID gives the current 15-min Bytes counter value |
| 1.3.6.1.4.1.20044.50.12.2.256.1.4 | Columnpmc1002perfdatacomclientCurrent15StatInCrcCountInvPortn | read-only | current | Client Current 15-min Input CRC counter inv. :This OID indicates that the current 15-min CRC counter is invalid |
| 1.3.6.1.4.1.20044.50.12.2.256.1.5 | Columnpmc1002perfdatacomclientCurrent15StatInCrcCountPortn | read-only | current | Client Current 15-min Input CRC counter :This OID gives the current 15-min CRC counter value |
| 1.3.6.1.4.1.20044.50.12.2.256.1.8 | Columnpmc1002perfdatacomclientCurrent15StatInBroadcastCountInvPortn | read-only | current | Client Current 15-min Input Broadcast counter inv. :This OID indicates that the current 15-min Broadcast counter is invalid |
| 1.3.6.1.4.1.20044.50.12.2.256.1.9 | Columnpmc1002perfdatacomclientCurrent15StatInBroadcastCountPortn | read-only | current | Client Current 15-min Input Broadcast counter :This OID gives the current 15-min Broadcast counter value |
| 1.3.6.1.4.1.20044.50.12.2.256.1.10 | Columnpmc1002perfdatacomclientCurrent15StatInMulticastCountInvPortn | read-only | current | Client Current 15-min Input Multicast counter inv. :This OID indicates that the current 15-min Multicast counter is invalid |
| 1.3.6.1.4.1.20044.50.12.2.256.1.11 | Columnpmc1002perfdatacomclientCurrent15StatInMulticastCountPortn | read-only | current | Client Current 15-min Input Multicast counter :This OID gives the current 15-min Multicast counter value |
| 1.3.6.1.4.1.20044.50.12.2.256.1.20 | Columnpmc1002perfdatacomclientCurrent15StatInUnicastCountInvPortn | read-only | current | Client Current 15-min Input Unicast counter inv. :This OID indicates that the current 15-min Unicast counter is invalid |
| 1.3.6.1.4.1.20044.50.12.2.256.1.21 | Columnpmc1002perfdatacomclientCurrent15StatInUnicastCountPortn | read-only | current | Client Current 15-min Input Unicast counter :This OID gives the current 15-min Unicast counter value |
| 1.3.6.1.4.1.20044.50.12.2.256.1.22 | Columnpmc1002perfdatacomclientCurrent15StatInNonunicastCountInvPortn | read-only | current | Client Current 15-min Input Non Unicast counter inv. :This OID indicates that the current 15-min Non unicast counter is invalid |
| 1.3.6.1.4.1.20044.50.12.2.256.1.23 | Columnpmc1002perfdatacomclientCurrent15StatInNonunicastCountPortn | read-only | current | Client Current 15-min Input Non Unicast counter :This OID gives the current 15-min Non Unicast counter value |
| 1.3.6.1.4.1.20044.50.12.2.256.1.26 | Columnpmc1002perfdatacomclientCurrent15StatOutBytesCountInvPortn | read-only | current | Client Current 15-min Output Bytes counter inv. :This OID indicates that the current 15-min Bytes counter is invalid |
| 1.3.6.1.4.1.20044.50.12.2.256.1.27 | Columnpmc1002perfdatacomclientCurrent15StatOutBytesCountPortn | read-only | current | Client Current 15-min Output Bytes counter :This OID gives the current 15-min Bytes counter value |
| 1.3.6.1.4.1.20044.50.12.2.256.1.32 | Columnpmc1002perfdatacomclientCurrent15StatOutBroadcastCountInvPortn | read-only | current | Client Current 15-min Output Broadcast counter inv. :This OID indicates that the current 15-min Broadcast counter is invalid |
| 1.3.6.1.4.1.20044.50.12.2.256.1.33 | Columnpmc1002perfdatacomclientCurrent15StatOutBroadcastCountPortn | read-only | current | Client Current 15-min Output Broadcast counter :This OID gives the current 15-min Broadcast counter value |
| 1.3.6.1.4.1.20044.50.12.2.256.1.34 | Columnpmc1002perfdatacomclientCurrent15StatOutMulticastCountInvPortn | read-only | current | Client Current 15-min Output Multicast counter inv. :This OID indicates that the current 15-min Multicast counter is invalid |
| 1.3.6.1.4.1.20044.50.12.2.256.1.35 | Columnpmc1002perfdatacomclientCurrent15StatOutMulticastCountPortn | read-only | current | Client Current 15-min Output Multicast counter :This OID gives the current 15-min Multicast counter value |
| 1.3.6.1.4.1.20044.50.12.2.256.1.42 | Columnpmc1002perfdatacomclientCurrent15StatOutUnicastCountInvPortn | read-only | current | Client Current 15-min Output Unicast counter inv. :This OID indicates that the current 15-min Unicast counter is invalid |
| 1.3.6.1.4.1.20044.50.12.2.256.1.43 | Columnpmc1002perfdatacomclientCurrent15StatOutUnicastCountPortn | read-only | current | Client Current 15-min Output Unicast counter :This OID gives the current 15-min Unicast counter value |
| 1.3.6.1.4.1.20044.50.12.2.256.1.44 | Columnpmc1002perfdatacomclientCurrent15StatOutNonunicastCountInvPortn | read-only | current | Client Current 15-min Output Non Unicast counter inv. :This OID indicates that the current 15-min Non Unicast counter is invalid |
| 1.3.6.1.4.1.20044.50.12.2.256.1.45 | Columnpmc1002perfdatacomclientCurrent15StatOutNonunicastCountPortn | read-only | current | Client Current 15-min Output Non Unicast counter :This OID gives the current 15-min Non Unicast counter value |
| 1.3.6.1.4.1.20044.50.12.2.264 | Tablepmc1002PerfDatacomClientPast15StatHistoryPort1Table | not-accessible | current | List of pmc1002PerfDatacomClientPast15StatHistory Article |
| 1.3.6.1.4.1.20044.50.12.2.264.1 | Rowpmc1002PerfDatacomClientPast15StatHistoryPort1Entry | not-accessible | current | Row definition for the pmc1002PerfDatacomClientPast15StatHistory table |
| 1.3.6.1.4.1.20044.50.12.2.264.1.1 | Columnpmc1002PerfDatacomClientPast15StatHistoryPort1Index | read-only | current | Index definition for the pmc1002PerfDatacomClientPast15StatHistory table |
| 1.3.6.1.4.1.20044.50.12.2.264.1.2 | Columnpmc1002perfdatacomclientPast15StatInBytesCountInvPort1 | read-only | current | Client Past 15-min Input Bytes counter inv. :This OID indicates that the past 15-min Bytes counter is invalid |
| 1.3.6.1.4.1.20044.50.12.2.264.1.3 | Columnpmc1002perfdatacomclientPast15StatInBytesCountPort1 | read-only | current | Client Past 15-min Input Bytes counter :This OID gives the past 15-min Bytes counter value |
| 1.3.6.1.4.1.20044.50.12.2.264.1.4 | Columnpmc1002perfdatacomclientPast15StatInCrcCountInvPort1 | read-only | current | Client Past 15-min Input CRC counter inv. :This OID indicates that the past 15-min CRC counter is invalid |
| 1.3.6.1.4.1.20044.50.12.2.264.1.5 | Columnpmc1002perfdatacomclientPast15StatInCrcCountPort1 | read-only | current | Client Past 15-min Input CRC counter :This OID gives the past 15-min CRC counter value |
| 1.3.6.1.4.1.20044.50.12.2.264.1.8 | Columnpmc1002perfdatacomclientPast15StatInBroadcastCountInvPort1 | read-only | current | Client Past 15-min Input Broadcast counter inv. :This OID indicates that the past 15-min Broadcast counter is invalid |
| 1.3.6.1.4.1.20044.50.12.2.264.1.9 | Columnpmc1002perfdatacomclientPast15StatInBroadcastCountPort1 | read-only | current | Client Past 15-min Input Broadcast counter :This OID gives the past 15-min Broadcast counter value |
| 1.3.6.1.4.1.20044.50.12.2.264.1.10 | Columnpmc1002perfdatacomclientPast15StatInMulticastCountInvPort1 | read-only | current | Client Past 15-min Input Multicast counter inv. :This OID indicates that the past 15-min Multicast counter is invalid |
| 1.3.6.1.4.1.20044.50.12.2.264.1.11 | Columnpmc1002perfdatacomclientPast15StatInMulticastCountPort1 | read-only | current | Client Past 15-min Input Multicast counter :This OID gives the past 15-min Multicast counter value |
| 1.3.6.1.4.1.20044.50.12.2.264.1.20 | Columnpmc1002perfdatacomclientPast15StatInUnicastCountInvPort1 | read-only | current | Client Past 15-min Input Unicast counter inv. :This OID indicates that the past 15-min Unicast counter is invalid |
| 1.3.6.1.4.1.20044.50.12.2.264.1.21 | Columnpmc1002perfdatacomclientPast15StatInUnicastCountPort1 | read-only | current | Client Past 15-min Input Unicast counter :This OID gives the past 15-min Unicast counter value |
| 1.3.6.1.4.1.20044.50.12.2.264.1.22 | Columnpmc1002perfdatacomclientPast15StatInNonunicastCountInvPort1 | read-only | current | Client Past 15-min Input Non Unicast counter inv. :This OID indicates that the past 15-min Non unicast counter is invalid |
| 1.3.6.1.4.1.20044.50.12.2.264.1.23 | Columnpmc1002perfdatacomclientPast15StatInNonunicastCountPort1 | read-only | current | Client Past 15-min Input Non Unicast counter :This OID gives the past 15-min Non Unicast counter value |
| 1.3.6.1.4.1.20044.50.12.2.264.1.26 | Columnpmc1002perfdatacomclientPast15StatOutBytesCountInvPort1 | read-only | current | Client Past 15-min Output Bytes counter inv. :This OID indicates that the past 15-min Bytes counter is invalid |
| 1.3.6.1.4.1.20044.50.12.2.264.1.27 | Columnpmc1002perfdatacomclientPast15StatOutBytesCountPort1 | read-only | current | Client Past 15-min Output Bytes counter :This OID gives the past 15-min Bytes counter value |
| 1.3.6.1.4.1.20044.50.12.2.264.1.32 | Columnpmc1002perfdatacomclientPast15StatOutBroadcastCountInvPort1 | read-only | current | Client Past 15-min Output Broadcast counter inv. :This OID indicates that the past 15-min Broadcast counter is invalid |
| 1.3.6.1.4.1.20044.50.12.2.264.1.33 | Columnpmc1002perfdatacomclientPast15StatOutBroadcastCountPort1 | read-only | current | Client Past 15-min Output Broadcast counter :This OID gives the past 15-min Broadcast counter value |
| 1.3.6.1.4.1.20044.50.12.2.264.1.34 | Columnpmc1002perfdatacomclientPast15StatOutMulticastCountInvPort1 | read-only | current | Client Past 15-min Output Multicast counter inv. :This OID indicates that the past 15-min Multicast counter is invalid |
| 1.3.6.1.4.1.20044.50.12.2.264.1.35 | Columnpmc1002perfdatacomclientPast15StatOutMulticastCountPort1 | read-only | current | Client Past 15-min Output Multicast counter :This OID gives the past 15-min Multicast counter value |
| 1.3.6.1.4.1.20044.50.12.2.264.1.42 | Columnpmc1002perfdatacomclientPast15StatOutUnicastCountInvPort1 | read-only | current | Client Past 15-min Output Unicast counter inv. :This OID indicates that the past 15-min Unicast counter is invalid |
| 1.3.6.1.4.1.20044.50.12.2.264.1.43 | Columnpmc1002perfdatacomclientPast15StatOutUnicastCountPort1 | read-only | current | Client Past 15-min Output Unicast counter :This OID gives the past 15-min Unicast counter value |
| 1.3.6.1.4.1.20044.50.12.2.264.1.44 | Columnpmc1002perfdatacomclientPast15StatOutNonunicastCountInvPort1 | read-only | current | Client Past 15-min Output Non Unicast counter inv. :This OID indicates that the past 15-min Non Unicast counter is invalid |
| 1.3.6.1.4.1.20044.50.12.2.264.1.45 | Columnpmc1002perfdatacomclientPast15StatOutNonunicastCountPort1 | read-only | current | Client Past 15-min Output Non Unicast counter :This OID gives the past 15-min Non Unicast counter value |
| 1.3.6.1.4.1.20044.50.12.2.272 | Tablepmc1002PerfDatacomClientCurrent24StatTable | not-accessible | current | List of pmc1002PerfDatacomClientCurrent24Stat Article |
| 1.3.6.1.4.1.20044.50.12.2.272.1 | Rowpmc1002PerfDatacomClientCurrent24StatEntry | not-accessible | current | Row definition for the pmc1002PerfDatacomClientCurrent24Stat table |
| 1.3.6.1.4.1.20044.50.12.2.272.1.1 | Columnpmc1002PerfDatacomClientCurrent24StatIndex | read-only | current | Index definition for the pmc1002PerfDatacomClientCurrent24Stat table |
| 1.3.6.1.4.1.20044.50.12.2.272.1.2 | Columnpmc1002perfdatacomclientCurrent24StatInBytesCountInvPortn | read-only | current | Client Current 24-hours Input Bytes counter inv. :This OID indicates that the current 24-hours Bytes counter is invalid |
| 1.3.6.1.4.1.20044.50.12.2.272.1.3 | Columnpmc1002perfdatacomclientCurrent24StatInBytesCountPortn | read-only | current | Client Current 24-hours Input Bytes counter :This OID gives the current 24-hours Bytes counter value |
| 1.3.6.1.4.1.20044.50.12.2.272.1.4 | Columnpmc1002perfdatacomclientCurrent24StatInCrcCountInvPortn | read-only | current | Client Current 24-hours Input CRC counter inv. :This OID indicates that the current 24-hours CRC counter is invalid |
| 1.3.6.1.4.1.20044.50.12.2.272.1.5 | Columnpmc1002perfdatacomclientCurrent24StatInCrcCountPortn | read-only | current | Client Current 24-hours Input CRC counter :This OID gives the current 24-hours CRC counter value |
| 1.3.6.1.4.1.20044.50.12.2.272.1.8 | Columnpmc1002perfdatacomclientCurrent24StatInBroadcastCountInvPortn | read-only | current | Client Current 24-hours Input Broadcast counter inv. :This OID indicates that the current 24-hours Broadcast counter is invalid |
| 1.3.6.1.4.1.20044.50.12.2.272.1.9 | Columnpmc1002perfdatacomclientCurrent24StatInBroadcastCountPortn | read-only | current | Client Current 24-hours Input Broadcast counter :This OID gives the current 24-hours Broadcast counter value |
| 1.3.6.1.4.1.20044.50.12.2.272.1.10 | Columnpmc1002perfdatacomclientCurrent24StatInMulticastCountInvPortn | read-only | current | Client Current 24-hours Input Multicast counter inv. :This OID indicates that the current 24-hours Multicast counter is invalid |
| 1.3.6.1.4.1.20044.50.12.2.272.1.11 | Columnpmc1002perfdatacomclientCurrent24StatInMulticastCountPortn | read-only | current | Client Current 24-hours Input Multicast counter :This OID gives the current 24-hours Multicast counter value |
| 1.3.6.1.4.1.20044.50.12.2.272.1.20 | Columnpmc1002perfdatacomclientCurrent24StatInUnicastCountInvPortn | read-only | current | Client Current 24-hours Input Unicast counter inv. :This OID indicates that the current 24-hours Unicast counter is invalid |
| 1.3.6.1.4.1.20044.50.12.2.272.1.21 | Columnpmc1002perfdatacomclientCurrent24StatInUnicastCountPortn | read-only | current | Client Current 24-hours Input Unicast counter :This OID gives the current 24-hours Unicast counter value |
| 1.3.6.1.4.1.20044.50.12.2.272.1.22 | Columnpmc1002perfdatacomclientCurrent24StatInNonunicastCountInvPortn | read-only | current | Client Current 24-hours Input Non Unicast counter inv. :This OID indicates that the current 24-hours Non unicast counter is invalid |
| 1.3.6.1.4.1.20044.50.12.2.272.1.23 | Columnpmc1002perfdatacomclientCurrent24StatInNonunicastCountPortn | read-only | current | Client Current 24-hours Input Non Unicast counter :This OID gives the current 24-hours Non Unicast counter value |
| 1.3.6.1.4.1.20044.50.12.2.272.1.26 | Columnpmc1002perfdatacomclientCurrent24StatOutBytesCountInvPortn | read-only | current | Client Current 24-hours Output Bytes counter inv. :This OID indicates that the current 24-hours Bytes counter is invalid |
| 1.3.6.1.4.1.20044.50.12.2.272.1.27 | Columnpmc1002perfdatacomclientCurrent24StatOutBytesCountPortn | read-only | current | Client Current 24-hours Output Bytes counter :This OID gives the current 24-hours Bytes counter value |
| 1.3.6.1.4.1.20044.50.12.2.272.1.32 | Columnpmc1002perfdatacomclientCurrent24StatOutBroadcastCountInvPortn | read-only | current | Client Current 24-hours Output Broadcast counter inv. :This OID indicates that the current 24-hours Broadcast counter is invalid |
| 1.3.6.1.4.1.20044.50.12.2.272.1.33 | Columnpmc1002perfdatacomclientCurrent24StatOutBroadcastCountPortn | read-only | current | Client Current 24-hours Output Broadcast counter :This OID gives the current 24-hours Broadcast counter value |
| 1.3.6.1.4.1.20044.50.12.2.272.1.34 | Columnpmc1002perfdatacomclientCurrent24StatOutMulticastCountInvPortn | read-only | current | Client Current 24-hours Output Multicast counter inv. :This OID indicates that the current 24-hours Multicast counter is invalid |
| 1.3.6.1.4.1.20044.50.12.2.272.1.35 | Columnpmc1002perfdatacomclientCurrent24StatOutMulticastCountPortn | read-only | current | Client Current 24-hours Output Multicast counter :This OID gives the current 24-hours Multicast counter value |
| 1.3.6.1.4.1.20044.50.12.2.272.1.42 | Columnpmc1002perfdatacomclientCurrent24StatOutUnicastCountInvPortn | read-only | current | Client Current 24-hours Output Unicast counter inv. :This OID indicates that the current 24-hours Unicast counter is invalid |
| 1.3.6.1.4.1.20044.50.12.2.272.1.43 | Columnpmc1002perfdatacomclientCurrent24StatOutUnicastCountPortn | read-only | current | Client Current 24-hours Output Unicast counter :This OID gives the current 24-hours Unicast counter value |
| 1.3.6.1.4.1.20044.50.12.2.272.1.44 | Columnpmc1002perfdatacomclientCurrent24StatOutNonunicastCountInvPortn | read-only | current | Client Current 24-hours Output Non Unicast counter inv. :This OID indicates that the current 24-hours Non Unicast counter is invalid |
| 1.3.6.1.4.1.20044.50.12.2.272.1.45 | Columnpmc1002perfdatacomclientCurrent24StatOutNonunicastCountPortn | read-only | current | Client Current 24-hours Output Non Unicast counter :This OID gives the current 24-hours Non Unicast counter value |
| 1.3.6.1.4.1.20044.50.12.2.280 | Tablepmc1002PerfDatacomClientPast24StatHistoryPort1Table | not-accessible | current | List of pmc1002PerfDatacomClientPast24StatHistory Article |
| 1.3.6.1.4.1.20044.50.12.2.280.1 | Rowpmc1002PerfDatacomClientPast24StatHistoryPort1Entry | not-accessible | current | Row definition for the pmc1002PerfDatacomClientPast24StatHistory table |
| 1.3.6.1.4.1.20044.50.12.2.280.1.1 | Columnpmc1002PerfDatacomClientPast24StatHistoryPort1Index | read-only | current | Index definition for the pmc1002PerfDatacomClientPast24StatHistory table |
| 1.3.6.1.4.1.20044.50.12.2.280.1.2 | Columnpmc1002perfdatacomclientPast24StatInBytesCountInvPort1 | read-only | current | Client Past 24-hours Input Bytes counter inv. :This OID indicates that the past 24-hours Bytes counter is invalid |
| 1.3.6.1.4.1.20044.50.12.2.280.1.3 | Columnpmc1002perfdatacomclientPast24StatInBytesCountPort1 | read-only | current | Client Past 24-hours Input Bytes counter :This OID gives the past 24-hours Bytes counter value |
| 1.3.6.1.4.1.20044.50.12.2.280.1.4 | Columnpmc1002perfdatacomclientPast24StatInCrcCountInvPort1 | read-only | current | Client Past 24-hours Input CRC counter inv. :This OID indicates that the past 24-hours CRC counter is invalid |
| 1.3.6.1.4.1.20044.50.12.2.280.1.5 | Columnpmc1002perfdatacomclientPast24StatInCrcCountPort1 | read-only | current | Client Past 24-hours Input CRC counter :This OID gives the past 24-hours CRC counter value |
| 1.3.6.1.4.1.20044.50.12.2.280.1.8 | Columnpmc1002perfdatacomclientPast24StatInBroadcastCountInvPort1 | read-only | current | Client Past 24-hours Input Broadcast counter inv. :This OID indicates that the past 24-hours Broadcast counter is invalid |
| 1.3.6.1.4.1.20044.50.12.2.280.1.9 | Columnpmc1002perfdatacomclientPast24StatInBroadcastCountPort1 | read-only | current | Client Past 24-hours Input Broadcast counter :This OID gives the past 24-hours Broadcast counter value |
| 1.3.6.1.4.1.20044.50.12.2.280.1.10 | Columnpmc1002perfdatacomclientPast24StatInMulticastCountInvPort1 | read-only | current | Client Past 24-hours Input Multicast counter inv. :This OID indicates that the past 24-hours Multicast counter is invalid |
| 1.3.6.1.4.1.20044.50.12.2.280.1.11 | Columnpmc1002perfdatacomclientPast24StatInMulticastCountPort1 | read-only | current | Client Past 24-hours Input Multicast counter :This OID gives the past 24-hours Multicast counter value |
| 1.3.6.1.4.1.20044.50.12.2.280.1.20 | Columnpmc1002perfdatacomclientPast24StatInUnicastCountInvPort1 | read-only | current | Client Past 24-hours Input Unicast counter inv. :This OID indicates that the past 24-hours Unicast counter is invalid |
| 1.3.6.1.4.1.20044.50.12.2.280.1.21 | Columnpmc1002perfdatacomclientPast24StatInUnicastCountPort1 | read-only | current | Client Past 24-hours Input Unicast counter :This OID gives the past 24-hours Unicast counter value |
| 1.3.6.1.4.1.20044.50.12.2.280.1.22 | Columnpmc1002perfdatacomclientPast24StatInNonunicastCountInvPort1 | read-only | current | Client Past 24-hours Input Non Unicast counter inv. :This OID indicates that the past 24-hours Non unicast counter is invalid |
| 1.3.6.1.4.1.20044.50.12.2.280.1.23 | Columnpmc1002perfdatacomclientPast24StatInNonunicastCountPort1 | read-only | current | Client Past 24-hours Input Non Unicast counter :This OID gives the past 24-hours Non Unicast counter value |
| 1.3.6.1.4.1.20044.50.12.2.280.1.26 | Columnpmc1002perfdatacomclientPast24StatOutBytesCountInvPort1 | read-only | current | Client Past 24-hours Output Bytes counter inv. :This OID indicates that the past 24-hours Bytes counter is invalid |
| 1.3.6.1.4.1.20044.50.12.2.280.1.27 | Columnpmc1002perfdatacomclientPast24StatOutBytesCountPort1 | read-only | current | Client Past 24-hours Output Bytes counter :This OID gives the past 24-hours Bytes counter value |
| 1.3.6.1.4.1.20044.50.12.2.280.1.32 | Columnpmc1002perfdatacomclientPast24StatOutBroadcastCountInvPort1 | read-only | current | Client Past 24-hours Output Broadcast counter inv. :This OID indicates that the past 24-hours Broadcast counter is invalid |
| 1.3.6.1.4.1.20044.50.12.2.280.1.33 | Columnpmc1002perfdatacomclientPast24StatOutBroadcastCountPort1 | read-only | current | Client Past 24-hours Output Broadcast counter :This OID gives the past 24-hours Broadcast counter value |
| 1.3.6.1.4.1.20044.50.12.2.280.1.34 | Columnpmc1002perfdatacomclientPast24StatOutMulticastCountInvPort1 | read-only | current | Client Past 24-hours Output Multicast counter inv. :This OID indicates that the past 24-hours Multicast counter is invalid |
| 1.3.6.1.4.1.20044.50.12.2.280.1.35 | Columnpmc1002perfdatacomclientPast24StatOutMulticastCountPort1 | read-only | current | Client Past 24-hours Output Multicast counter :This OID gives the past 24-hours Multicast counter value |
| 1.3.6.1.4.1.20044.50.12.2.280.1.42 | Columnpmc1002perfdatacomclientPast24StatOutUnicastCountInvPort1 | read-only | current | Client Past 24-hours Output Unicast counter inv. :This OID indicates that the past 24-hours Unicast counter is invalid |
| 1.3.6.1.4.1.20044.50.12.2.280.1.43 | Columnpmc1002perfdatacomclientPast24StatOutUnicastCountPort1 | read-only | current | Client Past 24-hours Output Unicast counter :This OID gives the past 24-hours Unicast counter value |
| 1.3.6.1.4.1.20044.50.12.2.280.1.44 | Columnpmc1002perfdatacomclientPast24StatOutNonunicastCountInvPort1 | read-only | current | Client Past 24-hours Output Non Unicast counter inv. :This OID indicates that the past 24-hours Non Unicast counter is invalid |
| 1.3.6.1.4.1.20044.50.12.2.280.1.45 | Columnpmc1002perfdatacomclientPast24StatOutNonunicastCountPort1 | read-only | current | Client Past 24-hours Output Non Unicast counter :This OID gives the past 24-hours Non Unicast counter value |
| 1.3.6.1.4.1.20044.50.12.3 | Nodepmc1002MonLine | |||
| 1.3.6.1.4.1.20044.50.12.3.128 | Tablepmc1002PerfTelecomLineCurrent15StatTable | not-accessible | current | List of pmc1002PerfTelecomLineCurrent15Stat Article |
| 1.3.6.1.4.1.20044.50.12.3.128.1 | Rowpmc1002PerfTelecomLineCurrent15StatEntry | not-accessible | current | Row definition for the pmc1002PerfTelecomLineCurrent15Stat table |
| 1.3.6.1.4.1.20044.50.12.3.128.1.1 | Columnpmc1002PerfTelecomLineCurrent15StatIndex | read-only | current | Index definition for the pmc1002PerfTelecomLineCurrent15Stat table |
| 1.3.6.1.4.1.20044.50.12.3.128.1.2 | Columnpmc1002PerfTelecomLineCurrent15StatInvCvPortn | read-only | current | Current 15-min CV counter inv. :This OID indicates that the current 15-min Coding Violation counter is invalid |
| 1.3.6.1.4.1.20044.50.12.3.128.1.3 | Columnpmc1002PerfTelecomLineCurrent15StatCvValuePortn | read-only | current | Current 15-min CV counter :This OID gives the current 15-min Coding Violation counter value |
| 1.3.6.1.4.1.20044.50.12.3.128.1.4 | Columnpmc1002PerfTelecomLineCurrent15StatInvEsPortn | read-only | current | Current 15-min ES counter inv. :This OID indicates that the current 15-min Errored Second counter is invalid |
| 1.3.6.1.4.1.20044.50.12.3.128.1.5 | Columnpmc1002PerfTelecomLineCurrent15StatEsValuePortn | read-only | current | Current 15-min ES counter :This OID gives the current 15-min Errored Second counter value |
| 1.3.6.1.4.1.20044.50.12.3.128.1.6 | Columnpmc1002PerfTelecomLineCurrent15StatInvSesPortn | read-only | current | Current 15-min SES counter inv. :This OID indicates that the current 15-min severely Errored Second counter is invalid |
| 1.3.6.1.4.1.20044.50.12.3.128.1.7 | Columnpmc1002PerfTelecomLineCurrent15StatSesValuePortn | read-only | current | Current 15-min SES counter :This OID gives the current 15-min severely Errored Second counter value |
| 1.3.6.1.4.1.20044.50.12.3.128.1.8 | Columnpmc1002PerfTelecomLineCurrent15StatInvSefsPortn | read-only | current | Current 15-min SEFS counter inv. :This OID indicates that the current 15-min severely Errored Framing Second counter is invalid |
| 1.3.6.1.4.1.20044.50.12.3.128.1.9 | Columnpmc1002PerfTelecomLineCurrent15StatSefsValuePortn | read-only | current | Current 15-min SEFS counter :This OID gives the current 15-min severely Errored Framing Second counter value |
| 1.3.6.1.4.1.20044.50.12.3.128.1.10 | Columnpmc1002PerfTelecomLineCurrent15StatInvUasPortn | read-only | current | Current 15-min UAS counter inv. :This OID indicates that the current 15-min UnAvailable Second counter is invalid |
| 1.3.6.1.4.1.20044.50.12.3.128.1.11 | Columnpmc1002PerfTelecomLineCurrent15StatUasValuePortn | read-only | current | Current 15-min UAS counter :This OID gives the current 15-min UnAvailable Second counter value |
| 1.3.6.1.4.1.20044.50.12.3.129 | Tablepmc1002PerfTelecomLinePast15StatHistoryPort1Table | not-accessible | current | List of pmc1002PerfTelecomLinePast15StatHistory Article |
| 1.3.6.1.4.1.20044.50.12.3.129.1 | Rowpmc1002PerfTelecomLinePast15StatHistoryPort1Entry | not-accessible | current | Row definition for the pmc1002PerfTelecomLinePast15StatHistory table |
| 1.3.6.1.4.1.20044.50.12.3.129.1.1 | Columnpmc1002PerfTelecomLinePast15StatHistoryPort1Index | read-only | current | Index definition for the pmc1002PerfTelecomLinePast15StatHistory table |
| 1.3.6.1.4.1.20044.50.12.3.129.1.2 | Columnpmc1002PerfTelecomLinePast15StatHistoryInvCvPort1 | read-only | current | Previous 15-min CV counter inv. :This OID indicates that the previous 15-min Coding Violation counter is invalid |
| 1.3.6.1.4.1.20044.50.12.3.129.1.3 | Columnpmc1002PerfTelecomLinePast15StatHistoryCvValuePort1 | read-only | current | Previous 15-min CV counter :This OID gives the previous 15-min Coding Violation counter value |
| 1.3.6.1.4.1.20044.50.12.3.129.1.4 | Columnpmc1002PerfTelecomLinePast15StatHistoryInvEsPort1 | read-only | current | Previous 15-min ES counter inv. :This OID indicates that the previous 15-min Errored Second counter is invalid |
| 1.3.6.1.4.1.20044.50.12.3.129.1.5 | Columnpmc1002PerfTelecomLinePast15StatHistoryEsValuePort1 | read-only | current | Previous 15-min ES counter :This OID gives the previous 15-min Errored Second counter value |
| 1.3.6.1.4.1.20044.50.12.3.129.1.6 | Columnpmc1002PerfTelecomLinePast15StatHistoryInvSesPort1 | read-only | current | Previous 15-min SES counter inv. :This OID indicates that the previous 15-min severely Errored Second counter is invalid |
| 1.3.6.1.4.1.20044.50.12.3.129.1.7 | Columnpmc1002PerfTelecomLinePast15StatHistorySesValuePort1 | read-only | current | Previous 15-min SES counter :This OID gives the previous 15-min severely Errored Second counter value |
| 1.3.6.1.4.1.20044.50.12.3.129.1.8 | Columnpmc1002PerfTelecomLinePast15StatHistoryInvSefsPort1 | read-only | current | Previous 15-min SEFS counter inv. :This OID indicates that the previous 15-min severely Errored Framing Second counter is invalid |
| 1.3.6.1.4.1.20044.50.12.3.129.1.9 | Columnpmc1002PerfTelecomLinePast15StatHistorySefsValuePort1 | read-only | current | Previous 15-min SEFS counter :This OID gives the previous 15-min severely Errored Framing Second counter value |
| 1.3.6.1.4.1.20044.50.12.3.129.1.10 | Columnpmc1002PerfTelecomLinePast15StatHistoryInvUasPort1 | read-only | current | Previous 15-min UAS counter inv. :This OID indicates that the previous 15-min UnAvailable Second counter is invalid |
| 1.3.6.1.4.1.20044.50.12.3.129.1.11 | Columnpmc1002PerfTelecomLinePast15StatHistoryUasValuePort1 | read-only | current | Previous 15-min UAS counter :This OID gives the previous 15-min UnAvailable Second counter value |
| 1.3.6.1.4.1.20044.50.12.3.130 | Tablepmc1002PerfTelecomLineCurrent24StatTable | not-accessible | current | List of pmc1002PerfTelecomLineCurrent24Stat Article |
| 1.3.6.1.4.1.20044.50.12.3.130.1 | Rowpmc1002PerfTelecomLineCurrent24StatEntry | not-accessible | current | Row definition for the pmc1002PerfTelecomLineCurrent24Stat table |
| 1.3.6.1.4.1.20044.50.12.3.130.1.1 | Columnpmc1002PerfTelecomLineCurrent24StatIndex | read-only | current | Index definition for the pmc1002PerfTelecomLineCurrent24Stat table |
| 1.3.6.1.4.1.20044.50.12.3.130.1.2 | Columnpmc1002PerfTelecomLineCurrent24StatInvCvPortn | read-only | current | Current 24-hours CV counter inv. :This OID indicates that the current 24-hours Coding Violation counter is invalid |
| 1.3.6.1.4.1.20044.50.12.3.130.1.3 | Columnpmc1002PerfTelecomLineCurrent24StatCvValuePortn | read-only | current | Current 24-hours CV counter :This OID gives the current 24-hours Coding Violation counter value |
| 1.3.6.1.4.1.20044.50.12.3.130.1.4 | Columnpmc1002PerfTelecomLineCurrent24StatInvEsPortn | read-only | current | Current 24-hours ES counter inv. :This OID indicates that the current 24-hours Errored Second counter is invalid |
| 1.3.6.1.4.1.20044.50.12.3.130.1.5 | Columnpmc1002PerfTelecomLineCurrent24StatEsValuePortn | read-only | current | Current 24-hours ES counter :This OID gives the current 24-hours Errored Second counter value |
| 1.3.6.1.4.1.20044.50.12.3.130.1.6 | Columnpmc1002PerfTelecomLineCurrent24StatInvSesPortn | read-only | current | Current 24-hours SES counter inv. :This OID indicates that the current 24-hours severely Errored Second counter is invalid |
| 1.3.6.1.4.1.20044.50.12.3.130.1.7 | Columnpmc1002PerfTelecomLineCurrent24StatSesValuePortn | read-only | current | Current 24-hours SES counter :This OID gives the current 24-hours severely Errored Second counter value |
| 1.3.6.1.4.1.20044.50.12.3.130.1.8 | Columnpmc1002PerfTelecomLineCurrent24StatInvSefsPortn | read-only | current | Current 24-hours SEFS counter inv. :This OID indicates that the current 24-hours severely Errored Framing Second counter is invalid |
| 1.3.6.1.4.1.20044.50.12.3.130.1.9 | Columnpmc1002PerfTelecomLineCurrent24StatSefsValuePortn | read-only | current | Current 24-hours SEFS counter :This OID gives the current 24-hours severely Errored Framing Second counter value |
| 1.3.6.1.4.1.20044.50.12.3.130.1.10 | Columnpmc1002PerfTelecomLineCurrent24StatInvUasPortn | read-only | current | Current 24-hours UAS counter inv. :This OID indicates that the current 24-hours UnAvailable Second counter is invalid |
| 1.3.6.1.4.1.20044.50.12.3.130.1.11 | Columnpmc1002PerfTelecomLineCurrent24StatUasValuePortn | read-only | current | Current 24-hours UAS counter :This OID gives the current 24-hours UnAvailable Second counter value |
| 1.3.6.1.4.1.20044.50.12.3.131 | Tablepmc1002PerfTelecomLinePast24StatHistoryPort1Table | not-accessible | current | List of pmc1002PerfTelecomLinePast24StatHistory Article |
| 1.3.6.1.4.1.20044.50.12.3.131.1 | Rowpmc1002PerfTelecomLinePast24StatHistoryPort1Entry | not-accessible | current | Row definition for the pmc1002PerfTelecomLinePast24StatHistory table |
| 1.3.6.1.4.1.20044.50.12.3.131.1.1 | Columnpmc1002PerfTelecomLinePast24StatHistoryPort1Index | read-only | current | Index definition for the pmc1002PerfTelecomLinePast24StatHistory table |
| 1.3.6.1.4.1.20044.50.12.3.131.1.2 | Columnpmc1002PerfTelecomLinePast24StatHistoryInvCvPort1 | read-only | current | Previous 24-hours CV counter inv. :This OID indicates that the previous 24-hours Coding Violation counter is invalid |
| 1.3.6.1.4.1.20044.50.12.3.131.1.3 | Columnpmc1002PerfTelecomLinePast24StatHistoryCvValuePort1 | read-only | current | Previous 24-hours CV counter :This OID gives the previous 24-hours Coding Violation counter value |
| 1.3.6.1.4.1.20044.50.12.3.131.1.4 | Columnpmc1002PerfTelecomLinePast24StatHistoryInvEsPort1 | read-only | current | Previous 24-hours ES counter inv. :This OID indicates that the previous 24-hours Errored Second counter is invalid |
| 1.3.6.1.4.1.20044.50.12.3.131.1.5 | Columnpmc1002PerfTelecomLinePast24StatHistoryEsValuePort1 | read-only | current | Previous 24-hours ES counter :This OID gives the previous 24-hours Errored Second counter value |
| 1.3.6.1.4.1.20044.50.12.3.131.1.6 | Columnpmc1002PerfTelecomLinePast24StatHistoryInvSesPort1 | read-only | current | Previous 24-hours SES counter inv. :This OID indicates that the previous 24-hours severely Errored Second counter is invalid |
| 1.3.6.1.4.1.20044.50.12.3.131.1.7 | Columnpmc1002PerfTelecomLinePast24StatHistorySesValuePort1 | read-only | current | Previous 24-hours SES counter :This OID gives the previous 24-hours severely Errored Second counter value |
| 1.3.6.1.4.1.20044.50.12.3.131.1.8 | Columnpmc1002PerfTelecomLinePast24StatHistoryInvSefsPort1 | read-only | current | Previous 24-hours SEFS counter inv. :This OID indicates that the previous 24-hours severely Errored Framing Second counter is invalid |
| 1.3.6.1.4.1.20044.50.12.3.131.1.9 | Columnpmc1002PerfTelecomLinePast24StatHistorySefsValuePort1 | read-only | current | Previous 24-hours SEFS counter :This OID gives the previous 24-hours severely Errored Framing Second counter value |
| 1.3.6.1.4.1.20044.50.12.3.131.1.10 | Columnpmc1002PerfTelecomLinePast24StatHistoryInvUasPort1 | read-only | current | Previous 24-hours UAS counter inv. :This OID indicates that the previous 24-hours UnAvailable Second counter is invalid |
| 1.3.6.1.4.1.20044.50.12.3.131.1.11 | Columnpmc1002PerfTelecomLinePast24StatHistoryUasValuePort1 | read-only | current | Previous 24-hours UAS counter :This OID gives the previous 24-hours UnAvailable Second counter value |
| 1.3.6.1.4.1.20044.50.12.4 | Nodepmc1002Rmon | |||
| 1.3.6.1.4.1.20044.50.12.4.1 | Nodepmc1002RmonClient | |||
| 1.3.6.1.4.1.20044.50.12.4.1.16 | Tablepmc1002MonupRmonByteCntTable | not-accessible | current | List of pmc1002MonupRmonByteCnt Article |
| 1.3.6.1.4.1.20044.50.12.4.1.16.1 | Rowpmc1002MonupRmonByteCntEntry | not-accessible | current | Row definition for the pmc1002MonupRmonByteCnt table |
| 1.3.6.1.4.1.20044.50.12.4.1.16.1.1 | Columnpmc1002MonupRmonByteCntIndex | read-only | current | Index definition for the pmc1002MonupRmonByteCnt table |
| 1.3.6.1.4.1.20044.50.12.4.1.16.1.2 | Columnpmc1002MonupRmonByteCntValuePortn | read-only | current | Client Input Bytes :This counter is increased each time a data byte is received on the client port <Help> This counter gives the number of bytes received on th… |
| 1.3.6.1.4.1.20044.50.12.4.1.16.1.3 | Columnpmc1002MonupRmonByteCntErrorPortn | read-only | current | Input Bytes Counter Error :This OID when set indicates the input Bytes counter value is invalid on client port |
| 1.3.6.1.4.1.20044.50.12.4.1.16.1.4 | Columnpmc1002MonupRmonByteCntOverloadPortn | read-only | current | Input Bytes Counter Overload :This OID when set indicates an input Bytes counter overload on client port |
| 1.3.6.1.4.1.20044.50.12.4.1.24 | Tablepmc1002MonupRmonCrcErrorCntTable | not-accessible | current | List of pmc1002MonupRmonCrcErrorCnt Article |
| 1.3.6.1.4.1.20044.50.12.4.1.24.1 | Rowpmc1002MonupRmonCrcErrorCntEntry | not-accessible | current | Row definition for the pmc1002MonupRmonCrcErrorCnt table |
| 1.3.6.1.4.1.20044.50.12.4.1.24.1.1 | Columnpmc1002MonupRmonCrcErrorCntIndex | read-only | current | Index definition for the pmc1002MonupRmonCrcErrorCnt table |
| 1.3.6.1.4.1.20044.50.12.4.1.24.1.2 | Columnpmc1002MonupRmonCrcErrorCntValuePortn | read-only | current | Client Input CRC Errors :This counter is increased each time a CRC error is detected on the client port. <Help> This counter gives the number of CRC Errors rec… |
| 1.3.6.1.4.1.20044.50.12.4.1.24.1.3 | Columnpmc1002MonupRmonCrcErrorCntErrorPortn | read-only | current | Input CRC Errors Counter Error :This OID when set indicates the input CRC Errors counter value is invalid on client port |
| 1.3.6.1.4.1.20044.50.12.4.1.24.1.4 | Columnpmc1002MonupRmonCrcErrorCntOverloadPortn | read-only | current | Input CRC Errors Counter Overload :This OID when set indicates an input CRC Errors counter overload on client port |
| 1.3.6.1.4.1.20044.50.12.4.1.32 | Tablepmc1002MonupRmonPacketsCntTable | not-accessible | current | List of pmc1002MonupRmonPacketsCnt Article |
| 1.3.6.1.4.1.20044.50.12.4.1.32.1 | Rowpmc1002MonupRmonPacketsCntEntry | not-accessible | current | Row definition for the pmc1002MonupRmonPacketsCnt table |
| 1.3.6.1.4.1.20044.50.12.4.1.32.1.1 | Columnpmc1002MonupRmonPacketsCntIndex | read-only | current | Index definition for the pmc1002MonupRmonPacketsCnt table |
| 1.3.6.1.4.1.20044.50.12.4.1.32.1.2 | Columnpmc1002MonupRmonPacketsCntValuePortn | read-only | current | Client Input Packets :This counter is increased each time a packet is received on the client port <Help> This counter gives the number of packets received on t… |
| 1.3.6.1.4.1.20044.50.12.4.1.32.1.3 | Columnpmc1002MonupRmonPacketsCntErrorPortn | read-only | current | Input Packets Counter Error :This OID when set indicates the input Packets counter value is invalid on client port |
| 1.3.6.1.4.1.20044.50.12.4.1.32.1.4 | Columnpmc1002MonupRmonPacketsCntOverloadPortn | read-only | current | Input Packets Counter Overload :This OID when set indicates an input Packets counter overload on client port |
| 1.3.6.1.4.1.20044.50.12.4.1.40 | Tablepmc1002MonupRmonBroadcastCntTable | not-accessible | current | List of pmc1002MonupRmonBroadcastCnt Article |
| 1.3.6.1.4.1.20044.50.12.4.1.40.1 | Rowpmc1002MonupRmonBroadcastCntEntry | not-accessible | current | Row definition for the pmc1002MonupRmonBroadcastCnt table |
| 1.3.6.1.4.1.20044.50.12.4.1.40.1.1 | Columnpmc1002MonupRmonBroadcastCntIndex | read-only | current | Index definition for the pmc1002MonupRmonBroadcastCnt table |
| 1.3.6.1.4.1.20044.50.12.4.1.40.1.2 | Columnpmc1002MonupRmonBroadcastCntValuePortn | read-only | current | Client Input Broadcast Packets :This counter is increased each time a broadcast packet is received on the client port. <Help> This counter gives the number of … |
| 1.3.6.1.4.1.20044.50.12.4.1.40.1.3 | Columnpmc1002MonupRmonBroadcastCntErrorPortn | read-only | current | Input Broadcast Counter Error :This OID when set indicates the input Broadcast counter value is invalid on client port |
| 1.3.6.1.4.1.20044.50.12.4.1.40.1.4 | Columnpmc1002MonupRmonBroadcastCntOverloadPortn | read-only | current | Input Broadcast Counter Overload :This OID when set indicates an input Broadcast counter overload on client port |
| 1.3.6.1.4.1.20044.50.12.4.1.48 | Tablepmc1002MonupRmonMulticastCntTable | not-accessible | current | List of pmc1002MonupRmonMulticastCnt Article |
| 1.3.6.1.4.1.20044.50.12.4.1.48.1 | Rowpmc1002MonupRmonMulticastCntEntry | not-accessible | current | Row definition for the pmc1002MonupRmonMulticastCnt table |
| 1.3.6.1.4.1.20044.50.12.4.1.48.1.1 | Columnpmc1002MonupRmonMulticastCntIndex | read-only | current | Index definition for the pmc1002MonupRmonMulticastCnt table |
| 1.3.6.1.4.1.20044.50.12.4.1.48.1.2 | Columnpmc1002MonupRmonMulticastCntValuePortn | read-only | current | Client Input Multicast Packets :This counter is increased each time a Multicast packet is received on the client port. <Help> This counter gives the number of … |
| 1.3.6.1.4.1.20044.50.12.4.1.48.1.3 | Columnpmc1002MonupRmonMulticastCntErrorPortn | read-only | current | Input Multicast Counter Error :This OID when set indicates the input Multicast counter value is invalid on client port |
| 1.3.6.1.4.1.20044.50.12.4.1.48.1.4 | Columnpmc1002MonupRmonMulticastCntOverloadPortn | read-only | current | Input Multicast Counter Overload :This OID when set indicates an input Multicast counter overload on client port |
| 1.3.6.1.4.1.20044.50.12.4.1.56 | Tablepmc1002MonupRmonTimerCntTable | not-accessible | current | List of pmc1002MonupRmonTimerCnt Article |
| 1.3.6.1.4.1.20044.50.12.4.1.56.1 | Rowpmc1002MonupRmonTimerCntEntry | not-accessible | current | Row definition for the pmc1002MonupRmonTimerCnt table |
| 1.3.6.1.4.1.20044.50.12.4.1.56.1.1 | Columnpmc1002MonupRmonTimerCntIndex | read-only | current | Index definition for the pmc1002MonupRmonTimerCnt table |
| 1.3.6.1.4.1.20044.50.12.4.1.56.1.2 | Columnpmc1002MonupRmonTimerCntValuePortn | read-only | current | RMON Timer On Client Input :This is the timing counter dedicated to the upstream RMON counters. It is incremented every 125 us. |
| 1.3.6.1.4.1.20044.50.12.4.1.56.1.3 | Columnpmc1002MonupRmonTimerCntErrorPortn | read-only | current | Input RMON Timer Error :This OID when set indicates the input RMON timer is invalid on client port |
| 1.3.6.1.4.1.20044.50.12.4.1.56.1.4 | Columnpmc1002MonupRmonTimerCntOverloadPortn | read-only | current | Input RMON Timer Overload :This OID when set indicates an input RMON timer overload on client port |
| 1.3.6.1.4.1.20044.50.12.4.1.64 | Tablepmc1002MonupRmonPauseFrameCntTable | not-accessible | current | List of pmc1002MonupRmonPauseFrameCnt Article |
| 1.3.6.1.4.1.20044.50.12.4.1.64.1 | Rowpmc1002MonupRmonPauseFrameCntEntry | not-accessible | current | Row definition for the pmc1002MonupRmonPauseFrameCnt table |
| 1.3.6.1.4.1.20044.50.12.4.1.64.1.1 | Columnpmc1002MonupRmonPauseFrameCntIndex | read-only | current | Index definition for the pmc1002MonupRmonPauseFrameCnt table |
| 1.3.6.1.4.1.20044.50.12.4.1.64.1.2 | Columnpmc1002MonupRmonPauseFrameCntValuePortn | read-only | current | Client Input Pause Frames :This counter is increased each time a Pause frame is received on the client port |
| 1.3.6.1.4.1.20044.50.12.4.1.64.1.3 | Columnpmc1002MonupRmonPauseFrameCntErrorPortn | read-only | current | Input Pause Counter Error :This OID when set indicates the input Pause counter value is invalid on client port |
| 1.3.6.1.4.1.20044.50.12.4.1.64.1.4 | Columnpmc1002MonupRmonPauseFrameCntOverloadPortn | read-only | current | Input Pause Counter Overload :This OID when set indicates an input Pause counter overload on client port |
| 1.3.6.1.4.1.20044.50.12.4.1.72 | Tablepmc1002MonupRmonDropFrameCntTable | not-accessible | current | List of pmc1002MonupRmonDropFrameCnt Article |
| 1.3.6.1.4.1.20044.50.12.4.1.72.1 | Rowpmc1002MonupRmonDropFrameCntEntry | not-accessible | current | Row definition for the pmc1002MonupRmonDropFrameCnt table |
| 1.3.6.1.4.1.20044.50.12.4.1.72.1.1 | Columnpmc1002MonupRmonDropFrameCntIndex | read-only | current | Index definition for the pmc1002MonupRmonDropFrameCnt table |
| 1.3.6.1.4.1.20044.50.12.4.1.72.1.2 | Columnpmc1002MonupRmonDropFrameCntValuePortn | read-only | current | Client Input Drop Packets :This counter is increased each time a Frame is dropped on the input client port |
| 1.3.6.1.4.1.20044.50.12.4.1.72.1.3 | Columnpmc1002MonupRmonDropFrameCntErrorPortn | read-only | current | Input Drop Counter Error :This OID when set indicates the input Drop counter value is invalid on client port |
| 1.3.6.1.4.1.20044.50.12.4.1.72.1.4 | Columnpmc1002MonupRmonDropFrameCntOverloadPortn | read-only | current | Input Drop Counter Overload :This OID when set indicates an input Drop counter overload on client port |
| 1.3.6.1.4.1.20044.50.12.4.1.80 | Tablepmc1002MonupRmonBitsCntTable | not-accessible | current | List of pmc1002MonupRmonBitsCnt Article |
| 1.3.6.1.4.1.20044.50.12.4.1.80.1 | Rowpmc1002MonupRmonBitsCntEntry | not-accessible | current | Row definition for the pmc1002MonupRmonBitsCnt table |
| 1.3.6.1.4.1.20044.50.12.4.1.80.1.1 | Columnpmc1002MonupRmonBitsCntIndex | read-only | current | Index definition for the pmc1002MonupRmonBitsCnt table |
| 1.3.6.1.4.1.20044.50.12.4.1.80.1.2 | Columnpmc1002MonupRmonBitsCntValuePortn | read-only | current | Client Input Bits :This counter is increased each time a bit is received on the input client port |
| 1.3.6.1.4.1.20044.50.12.4.1.80.1.3 | Columnpmc1002MonupRmonBitsCntErrorPortn | read-only | current | Input Bits Counter Error :This OID when set indicates the input Bits counter value is invalid on client port |
| 1.3.6.1.4.1.20044.50.12.4.1.80.1.4 | Columnpmc1002MonupRmonBitsCntOverloadPortn | read-only | current | Input Bits Counter Overload :This OID when set indicates an input Bits counter overload on client port |
| 1.3.6.1.4.1.20044.50.12.4.1.88 | Tablepmc1002MonupRmonUnicastCntTable | not-accessible | current | List of pmc1002MonupRmonUnicastCnt Article |
| 1.3.6.1.4.1.20044.50.12.4.1.88.1 | Rowpmc1002MonupRmonUnicastCntEntry | not-accessible | current | Row definition for the pmc1002MonupRmonUnicastCnt table |
| 1.3.6.1.4.1.20044.50.12.4.1.88.1.1 | Columnpmc1002MonupRmonUnicastCntIndex | read-only | current | Index definition for the pmc1002MonupRmonUnicastCnt table |
| 1.3.6.1.4.1.20044.50.12.4.1.88.1.2 | Columnpmc1002MonupRmonUnicastCntValuePortn | read-only | current | Client Input Unicast Packets :This counter is increased each time a Unicast packet is received on client input <Help> This counter gives the number of Unicast … |
| 1.3.6.1.4.1.20044.50.12.4.1.88.1.3 | Columnpmc1002MonupRmonUnicastCntErrorPortn | read-only | current | Input Unicast Counter Error :This OID when set indicates the input Drop counter value is invalid on client port |
| 1.3.6.1.4.1.20044.50.12.4.1.88.1.4 | Columnpmc1002MonupRmonUnicastCntOverloadPortn | read-only | current | Input Unicast Counter Overload :This OID when set indicates an input Drop counter overload on client port |
| 1.3.6.1.4.1.20044.50.12.4.1.96 | Tablepmc1002MonupRmonNonUnicastCntTable | not-accessible | current | List of pmc1002MonupRmonNonUnicastCnt Article |
| 1.3.6.1.4.1.20044.50.12.4.1.96.1 | Rowpmc1002MonupRmonNonUnicastCntEntry | not-accessible | current | Row definition for the pmc1002MonupRmonNonUnicastCnt table |
| 1.3.6.1.4.1.20044.50.12.4.1.96.1.1 | Columnpmc1002MonupRmonNonUnicastCntIndex | read-only | current | Index definition for the pmc1002MonupRmonNonUnicastCnt table |
| 1.3.6.1.4.1.20044.50.12.4.1.96.1.2 | Columnpmc1002MonupRmonNonUnicastCntValuePortn | read-only | current | Client Input Non Unicast Packets :This counter is increased each time a Non Unicast packet is received on client input <Help> This counter gives the number of … |
| 1.3.6.1.4.1.20044.50.12.4.1.96.1.3 | Columnpmc1002MonupRmonNonUnicastCntErrorPortn | read-only | current | Input Non Unicast Counter Error :This OID when set indicates the input Bits counter value is invalid on client port |
| 1.3.6.1.4.1.20044.50.12.4.1.96.1.4 | Columnpmc1002MonupRmonNonUnicastCntOverloadPortn | read-only | current | Input Non Unicast Counter Overload :This OID when set indicates an input Bits counter overload on client port |
| 1.3.6.1.4.1.20044.50.12.4.1.112 | Tablepmc1002MondwRmonByteCntTable | not-accessible | current | List of pmc1002MondwRmonByteCnt Article |
| 1.3.6.1.4.1.20044.50.12.4.1.112.1 | Rowpmc1002MondwRmonByteCntEntry | not-accessible | current | Row definition for the pmc1002MondwRmonByteCnt table |
| 1.3.6.1.4.1.20044.50.12.4.1.112.1.1 | Columnpmc1002MondwRmonByteCntIndex | read-only | current | Index definition for the pmc1002MondwRmonByteCnt table |
| 1.3.6.1.4.1.20044.50.12.4.1.112.1.2 | Columnpmc1002MondwRmonByteCntValuePortn | read-only | current | Client Output Bytes :This counter is increased each time a data byte is transmitted on the client port. <Help> This counter gives the number of bytes transmitt… |
| 1.3.6.1.4.1.20044.50.12.4.1.112.1.3 | Columnpmc1002MondwRmonByteCntErrorPortn | read-only | current | Output Bytes Counter Error :This OID when set indicates the output Bytes counter value is invalid on client port |
| 1.3.6.1.4.1.20044.50.12.4.1.112.1.4 | Columnpmc1002MondwRmonByteCntOverloadPortn | read-only | current | Output Bytes Counter Overload :This OID when set indicates an output Bytes counter overload on client port |
| 1.3.6.1.4.1.20044.50.12.4.1.120 | Tablepmc1002MondwRmonCrcErrorCntTable | not-accessible | current | List of pmc1002MondwRmonCrcErrorCnt Article |
| 1.3.6.1.4.1.20044.50.12.4.1.120.1 | Rowpmc1002MondwRmonCrcErrorCntEntry | not-accessible | current | Row definition for the pmc1002MondwRmonCrcErrorCnt table |
| 1.3.6.1.4.1.20044.50.12.4.1.120.1.1 | Columnpmc1002MondwRmonCrcErrorCntIndex | read-only | current | Index definition for the pmc1002MondwRmonCrcErrorCnt table |
| 1.3.6.1.4.1.20044.50.12.4.1.120.1.2 | Columnpmc1002MondwRmonCrcErrorCntValuePortn | read-only | current | Client Output CRC Errors :This counter is increased each time a CRC error is detected on the output client port <Help> This counter gives the number of CRC Err… |
| 1.3.6.1.4.1.20044.50.12.4.1.120.1.3 | Columnpmc1002MondwRmonCrcErrorCntErrorPortn | read-only | current | Output CRC Errors Counter Error :This OID when set indicates the output CRC Errors counter value is invalid on client port |
| 1.3.6.1.4.1.20044.50.12.4.1.120.1.4 | Columnpmc1002MondwRmonCrcErrorCntOverloadPortn | read-only | current | Output CRC Errors Counter Overload :This OID when set indicates an output CRC Errors counter overload on client port |
| 1.3.6.1.4.1.20044.50.12.4.1.128 | Tablepmc1002MondwRmonPacketsCntTable | not-accessible | current | List of pmc1002MondwRmonPacketsCnt Article |
| 1.3.6.1.4.1.20044.50.12.4.1.128.1 | Rowpmc1002MondwRmonPacketsCntEntry | not-accessible | current | Row definition for the pmc1002MondwRmonPacketsCnt table |
| 1.3.6.1.4.1.20044.50.12.4.1.128.1.1 | Columnpmc1002MondwRmonPacketsCntIndex | read-only | current | Index definition for the pmc1002MondwRmonPacketsCnt table |
| 1.3.6.1.4.1.20044.50.12.4.1.128.1.2 | Columnpmc1002MondwRmonPacketsCntValuePortn | read-only | current | Client Output Packets :This counter is increased each time a packet is transmitted on the client port. <Help> This counter gives the number of packets transmit… |
| 1.3.6.1.4.1.20044.50.12.4.1.128.1.3 | Columnpmc1002MondwRmonPacketsCntErrorPortn | read-only | current | Output Packets Counter Error :This OID when set indicates the output Packets counter value is invalid on client port |
| 1.3.6.1.4.1.20044.50.12.4.1.128.1.4 | Columnpmc1002MondwRmonPacketsCntOverloadPortn | read-only | current | Output Packets Counter Overload :This OID when set indicates an output Packets counter overload on client port |
| 1.3.6.1.4.1.20044.50.12.4.1.136 | Tablepmc1002MondwRmonBroadcastCntTable | not-accessible | current | List of pmc1002MondwRmonBroadcastCnt Article |
| 1.3.6.1.4.1.20044.50.12.4.1.136.1 | Rowpmc1002MondwRmonBroadcastCntEntry | not-accessible | current | Row definition for the pmc1002MondwRmonBroadcastCnt table |
| 1.3.6.1.4.1.20044.50.12.4.1.136.1.1 | Columnpmc1002MondwRmonBroadcastCntIndex | read-only | current | Index definition for the pmc1002MondwRmonBroadcastCnt table |
| 1.3.6.1.4.1.20044.50.12.4.1.136.1.2 | Columnpmc1002MondwRmonBroadcastCntValuePortn | read-only | current | Client Output Broadcast Packets :This counter is increased each time a broadcast packet is transmitted on the client port. <Help> This counter gives the number… |
| 1.3.6.1.4.1.20044.50.12.4.1.136.1.3 | Columnpmc1002MondwRmonBroadcastCntErrorPortn | read-only | current | Output Broadcast Counter Error :This OID when set indicates the output Broadcast counter value is invalid on client port |
| 1.3.6.1.4.1.20044.50.12.4.1.136.1.4 | Columnpmc1002MondwRmonBroadcastCntOverloadPortn | read-only | current | Output Broadcast Counter Overload :This OID when set indicates an output Broadcast counter overload on client port |
| 1.3.6.1.4.1.20044.50.12.4.1.144 | Tablepmc1002MondwRmonMulticastCntTable | not-accessible | current | List of pmc1002MondwRmonMulticastCnt Article |
| 1.3.6.1.4.1.20044.50.12.4.1.144.1 | Rowpmc1002MondwRmonMulticastCntEntry | not-accessible | current | Row definition for the pmc1002MondwRmonMulticastCnt table |
| 1.3.6.1.4.1.20044.50.12.4.1.144.1.1 | Columnpmc1002MondwRmonMulticastCntIndex | read-only | current | Index definition for the pmc1002MondwRmonMulticastCnt table |
| 1.3.6.1.4.1.20044.50.12.4.1.144.1.2 | Columnpmc1002MondwRmonMulticastCntValuePortn | read-only | current | Client Output Multicast Packets :This counter is increased each time a Multicast packet is tra,smitted on the client port. <Help> This counter gives the number… |
| 1.3.6.1.4.1.20044.50.12.4.1.144.1.3 | Columnpmc1002MondwRmonMulticastCntErrorPortn | read-only | current | Output Multicast Counter Error :This OID when set indicates the output Multicast counter value is invalid on client port |
| 1.3.6.1.4.1.20044.50.12.4.1.144.1.4 | Columnpmc1002MondwRmonMulticastCntOverloadPortn | read-only | current | Output Multicast Counter Overload :This OID when set indicates an output Multicast counter overload on client port |
| 1.3.6.1.4.1.20044.50.12.4.1.152 | Tablepmc1002MondwRmonPauseFrameCntTable | not-accessible | current | List of pmc1002MondwRmonPauseFrameCnt Article |
| 1.3.6.1.4.1.20044.50.12.4.1.152.1 | Rowpmc1002MondwRmonPauseFrameCntEntry | not-accessible | current | Row definition for the pmc1002MondwRmonPauseFrameCnt table |
| 1.3.6.1.4.1.20044.50.12.4.1.152.1.1 | Columnpmc1002MondwRmonPauseFrameCntIndex | read-only | current | Index definition for the pmc1002MondwRmonPauseFrameCnt table |
| 1.3.6.1.4.1.20044.50.12.4.1.152.1.2 | Columnpmc1002MondwRmonPauseFrameCntValuePortn | read-only | current | Client Output Pause Frames :This counter is increased each time a Pause frame is generated by the PM on the client port |
| 1.3.6.1.4.1.20044.50.12.4.1.152.1.3 | Columnpmc1002MondwRmonPauseFrameCntErrorPortn | read-only | current | Output Pause Counter Error :This OID when set indicates the output Pause counter value is invalid on client port |
| 1.3.6.1.4.1.20044.50.12.4.1.152.1.4 | Columnpmc1002MondwRmonPauseFrameCntOverloadPortn | read-only | current | Output Pause Counter Overload :This OID when set indicates an output Pause counter overload on client port |
| 1.3.6.1.4.1.20044.50.12.4.1.160 | Tablepmc1002MondwRmonTimerCntTable | not-accessible | current | List of pmc1002MondwRmonTimerCnt Article |
| 1.3.6.1.4.1.20044.50.12.4.1.160.1 | Rowpmc1002MondwRmonTimerCntEntry | not-accessible | current | Row definition for the pmc1002MondwRmonTimerCnt table |
| 1.3.6.1.4.1.20044.50.12.4.1.160.1.1 | Columnpmc1002MondwRmonTimerCntIndex | read-only | current | Index definition for the pmc1002MondwRmonTimerCnt table |
| 1.3.6.1.4.1.20044.50.12.4.1.160.1.2 | Columnpmc1002MondwRmonTimerCntValuePortn | read-only | current | RMON Timer On Client Output :This is the timing counter dedicated to the downstream RMON counters. It is incremented every 125 us. |
| 1.3.6.1.4.1.20044.50.12.4.1.160.1.3 | Columnpmc1002MondwRmonTimerCntErrorPortn | read-only | current | Output RMON Timer Error :This OID when set indicates the output RMON timer is invalid on client port |
| 1.3.6.1.4.1.20044.50.12.4.1.160.1.4 | Columnpmc1002MondwRmonTimerCntOverloadPortn | read-only | current | Output RMON Timer Overload :This OID when set indicates an output RMON timer overload on client port |
| 1.3.6.1.4.1.20044.50.12.4.1.168 | Tablepmc1002MondwRmonBitsCntTable | not-accessible | current | List of pmc1002MondwRmonBitsCnt Article |
| 1.3.6.1.4.1.20044.50.12.4.1.168.1 | Rowpmc1002MondwRmonBitsCntEntry | not-accessible | current | Row definition for the pmc1002MondwRmonBitsCnt table |
| 1.3.6.1.4.1.20044.50.12.4.1.168.1.1 | Columnpmc1002MondwRmonBitsCntIndex | read-only | current | Index definition for the pmc1002MondwRmonBitsCnt table |
| 1.3.6.1.4.1.20044.50.12.4.1.168.1.2 | Columnpmc1002MondwRmonBitsCntValuePortn | read-only | current | Client Output Bits :This counter is increased each time a bit is received on the Output client port |
| 1.3.6.1.4.1.20044.50.12.4.1.168.1.3 | Columnpmc1002MondwRmonBitsCntErrorPortn | read-only | current | Output Bits Counter Error :This OID when set indicates the output Bits counter value is invalid on client port |
| 1.3.6.1.4.1.20044.50.12.4.1.168.1.4 | Columnpmc1002MondwRmonBitsCntOverloadPortn | read-only | current | Output Bits Counter Overload :This OID when set indicates an output Bits counter overload on client port |
| 1.3.6.1.4.1.20044.50.12.4.1.176 | Tablepmc1002MondwRmonUnicastCntTable | not-accessible | current | List of pmc1002MondwRmonUnicastCnt Article |
| 1.3.6.1.4.1.20044.50.12.4.1.176.1 | Rowpmc1002MondwRmonUnicastCntEntry | not-accessible | current | Row definition for the pmc1002MondwRmonUnicastCnt table |
| 1.3.6.1.4.1.20044.50.12.4.1.176.1.1 | Columnpmc1002MondwRmonUnicastCntIndex | read-only | current | Index definition for the pmc1002MondwRmonUnicastCnt table |
| 1.3.6.1.4.1.20044.50.12.4.1.176.1.2 | Columnpmc1002MondwRmonUnicastCntValuePortn | read-only | current | Client Output Unicast Packets :This counter is increased each time a Unicast packet is transmitted on client port <Help> This counter gives the number of Unica… |
| 1.3.6.1.4.1.20044.50.12.4.1.176.1.3 | Columnpmc1002MondwRmonUnicastCntErrorPortn | read-only | current | Output Unicast Counter Error :This OID when set indicates the output RMON timer is invalid on client port |
| 1.3.6.1.4.1.20044.50.12.4.1.176.1.4 | Columnpmc1002MondwRmonUnicastCntOverloadPortn | read-only | current | Output Unicast Counter Overload :This OID when set indicates an output RMON timer overload on client port |
| 1.3.6.1.4.1.20044.50.12.4.1.184 | Tablepmc1002MondwRmonNonUnicastCntTable | not-accessible | current | List of pmc1002MondwRmonNonUnicastCnt Article |
| 1.3.6.1.4.1.20044.50.12.4.1.184.1 | Rowpmc1002MondwRmonNonUnicastCntEntry | not-accessible | current | Row definition for the pmc1002MondwRmonNonUnicastCnt table |
| 1.3.6.1.4.1.20044.50.12.4.1.184.1.1 | Columnpmc1002MondwRmonNonUnicastCntIndex | read-only | current | Index definition for the pmc1002MondwRmonNonUnicastCnt table |
| 1.3.6.1.4.1.20044.50.12.4.1.184.1.2 | Columnpmc1002MondwRmonNonUnicastCntValuePortn | read-only | current | Client Output Non Unicast Packets :This counter is increased each time a Non Unicast packet is transmitted on client port <Help> This counter gives the number … |
| 1.3.6.1.4.1.20044.50.12.4.1.184.1.3 | Columnpmc1002MondwRmonNonUnicastCntErrorPortn | read-only | current | Output Non Unicast Counter Error :This OID when set indicates the output Bits counter value is invalid on client port |
| 1.3.6.1.4.1.20044.50.12.4.1.184.1.4 | Columnpmc1002MondwRmonNonUnicastCntOverloadPortn | read-only | current | Output Non Unicast Counter Overload :This OID when set indicates an output Bits counter overload on client port |
| 1.3.6.1.4.1.20044.50.12.4.2 | Nodepmc1002RmonLine | |||
| 1.3.6.1.4.1.20044.50.12.4.3 | Nodepmc1002RmonOther | |||
| 1.3.6.1.4.1.20044.50.12.4.3.359 | Scalarpmc1002MonCountersReset | read-write | current | RMON Counters Reset:This OID resets and restarts all the RMON counters |
| 1.3.6.1.4.1.20044.50.12.4.3.360 | Scalarpmc1002MonCountersStop | read-write | current | RMON Counters stop:This OID stops all the RMON counters |
Type Definitions
| Name | Syntax | Status | Description |
|---|---|---|---|
| Pmc1002AdjustValue | INTEGER { otxadjustvalue0(0), otxadjustvalue1(1), otxadjustvalue2(2), otxadjustvalue3(3), otxadjustvalue4(4), otxadjustvalue5(5), otxadjustvalue6(6), otxadjustvalue7(7), otxadjustvalue8(8), otxadjustvalue9(9), otxadjustvalue10(10) } | current | Different values in Adjust mode on OTX-TLH on client and line ports |
| Pmc1002DccMode | INTEGER { dccNo(0), dcctermLine1(1), dcctermLine2(2), dcctermLines12(3), dccmaster(4), dccslaveLine12(7) } | current | Mode for DCC |
| Pmc1002Mode | INTEGER { modedual(0), modeprotect(1), moderegen(2) } | current | Different modes for the module |
| Pmc1002OtxChannel | INTEGER | current | Channel selection on OTX-TLH on client and line ports |
| Pmc1002OtxGrid | INTEGER { otxgrid200(200), otxgrid100(100), otxgrid50(50) } | current | Different grids on OTX-TLH on client and line ports |
| Pmc1002OtxMode | INTEGER { otx80mode(1), otx60mode(2), otxadjustmode(4) } | current | Different modes on OTX-TLH on client and line ports |