OIDNameAccessStatusDescription
1.3.6.1.4.1.20044.58IdentitymodulePm10010mpCreation.
1.3.6.1.4.1.20044.58.2Nodepm10010mpalarms
1.3.6.1.4.1.20044.58.2.1Nodepm10010mpAlmOther
1.3.6.1.4.1.20044.58.2.1.1Nodepm10010mpAlmOtherNurg
1.3.6.1.4.1.20044.58.2.1.1.2Nodepm10010mpAlmsynthAlm2
1.3.6.1.4.1.20044.58.2.1.1.2.1Scalarpm10010mpAlmConfTableSaveread-onlycurrentPM Configuration Save :This OID is at 1 during the saving of a new configuration table in the module Flash memory. <Condtype> CONF_TABLE_SAVE <Probcause> infor…
1.3.6.1.4.1.20044.58.2.1.1.2.2Scalarpm10010mpAlmInvUploadread-onlycurrentInventory Upload :This OID is at 1 during the uploading of PM inventory information. <Condtype> INV_UPLOAD <Probcause> informationalStatus(1000) <Alarmtype> ot…
1.3.6.1.4.1.20044.58.2.1.1.2.3Scalarpm10010mpAlmConfTableLoadread-onlycurrentPM Configuration Load :This OID is at 1 during the loading of configuration tables in the modules RAM. <Condtype> CONF_TABLE_LOAD <Probcause> informationalStat…
1.3.6.1.4.1.20044.58.2.1.1.2.4Scalarpm10010mpAlmCorrelatOffread-onlycurrentNot Used :This OID, when set, indicates that alarm correlation is not being performed. <Condtype> CORRELAT_OFF <Probcause> informationalStatus(1000) <Alarmtype…
1.3.6.1.4.1.20044.58.2.1.1.2.5Scalarpm10010mpAlmMaintenanceOnread-onlycurrentMaintenance Mode :This OID indicates that the RM is in maintenance mode. <Help> This alarm indicates that the maintenance mode is enabled on the PM <Condtype> …
1.3.6.1.4.1.20044.58.2.1.2Nodepm10010mpAlmOtherUrg
1.3.6.1.4.1.20044.58.2.1.3Nodepm10010mpAlmOtherCrit
1.3.6.1.4.1.20044.58.2.1.3.0Nodepm10010mpAlmsynthAlm0
1.3.6.1.4.1.20044.58.2.1.3.0.2Scalarpm10010mpAlmFailFanread-onlycurrentFan Fail :This OID is at 1 when any fail occurs on the fan tray <Help> This alarm indicates that the Fan tray module is in a failure condition <Condtype> FAIL_…
1.3.6.1.4.1.20044.58.2.1.3.0.9Scalarpm10010mpAlmModGlobFailread-onlycurrentModule Failure :This OID is set on detection of a failure originating from the RM <Help> This alarm is set on detection of a failure originating from the equip…
1.3.6.1.4.1.20044.58.2.1.3.0.15Scalarpm10010mpAlmDefFuseAread-onlycurrentFuse A Fail :This OID indicates that the fuse of the power input A is in fail condition <Help> Status of the Fuse A <Condtype> DEF_FUSE_A <Probcause> powerProb…
1.3.6.1.4.1.20044.58.2.1.3.0.16Scalarpm10010mpAlmDefFuseBread-onlycurrentFuse B Fail :This OID indicates that the fuse of the power input B is in fail condition <Help> Status of the Fuse B <Condtype> DEF_FUSE_B <Probcause> powerProb…
1.3.6.1.4.1.20044.58.2.1.3.40Nodepm10010mpAlmclientModuleState
1.3.6.1.4.1.20044.58.2.1.3.40.1Scalarpm10010mpAlmCfpInitializeread-onlycurrentClient Trscv Initialize :This OID indicates the Client Trscv initialization is in progress <Help> Status indicating the Client Trscv initialization is in progr…
1.3.6.1.4.1.20044.58.2.1.3.40.2Scalarpm10010mpAlmCfpLowPowerread-onlycurrentClient Trscv Low Power :This OID indicates the Client Trscv is in low power state <Help> Status indicating the Client Trscv is in low power state <Condtype> CF…
1.3.6.1.4.1.20044.58.2.1.3.40.3Scalarpm10010mpAlmCfpHighPowerUpread-onlycurrentClient Trscv High Power Up :This OID indicates the Client Trscv is leaving Low Power state <Help> Status indicating the Client Trscv is leaving Low Power state…
1.3.6.1.4.1.20044.58.2.1.3.40.4Scalarpm10010mpAlmCfpTxOffread-onlycurrentClient Trscv Laser Shutdown :This OID indicates the Client Trscv Laser is OFF <Help> Status indicating the Client Trscv Laser is OFF <Condtype> CFP_TX_OFF <Pro…
1.3.6.1.4.1.20044.58.2.1.3.40.5Scalarpm10010mpAlmCfpTxTurnOnread-onlycurrentClient Trscv Laser Turn On :This OID indicates the Client Trscv is turning on its laser <Help> Status indicating the Client Trscv is turning on its laser <Cond…
1.3.6.1.4.1.20044.58.2.1.3.40.6Scalarpm10010mpAlmCfpReadyread-onlycurrentClient Trscv Ready :This OID indicates the Client Trscv is ready to operate <Help> Status indicating the Client Trscv is ready to operate <Condtype> CFP_READY …
1.3.6.1.4.1.20044.58.2.1.3.40.7Scalarpm10010mpAlmCfpFaultread-onlycurrentClient Trscv Fault :This OID indicates the Client Trscv is in Fault state <Help> Status indicating the Client Trscv is in Fault state <Condtype> CFP_FAULT <Pro…
1.3.6.1.4.1.20044.58.2.1.3.40.8Scalarpm10010mpAlmCfpTxTurnOffread-onlycurrentClient Trscv Laser Turn Off :This OID indicates the Client Trscv is turning off its laser <Help> Status indicating the Client Trscv is turning off its laser <C…
1.3.6.1.4.1.20044.58.2.1.3.40.9Scalarpm10010mpAlmCfpHighPowerDownread-onlycurrentClient Trscv High Power Down :This OID indicates the Client Trscv is entering Low Power state <Help> Status indicating the Client Trscv is entering Low Power s…
1.3.6.1.4.1.20044.58.2.1.3.41Nodepm10010mpAlmclientModuleGeneralStatus
1.3.6.1.4.1.20044.58.2.1.3.41.4Scalarpm10010mpAlmCfpOutOfAlignmentread-onlycurrentClient Trscv Out Of Alignment :This OID indicates an Out of alignment on the Client Trscv Host Interface <Help> Alarm indicating an Out of alignment on the Cli…
1.3.6.1.4.1.20044.58.2.1.3.41.5Scalarpm10010mpAlmCfpRxNetworkLolread-onlycurrentClient Trscv Rx Network Loss Of Lock :This OID indicates of Loss of Lock is dected on the Client Trscv Rx Network interface <Help> Alarm indicating of Loss of …
1.3.6.1.4.1.20044.58.2.1.3.41.6Scalarpm10010mpAlmCfpRxLosread-onlycurrentClient Trscv Loss Of Signal :This OID indicates a Loss of Signal is detected on the Client Trscv <Help> Alarm indicating a Loss of Signal is detected on the Cl…
1.3.6.1.4.1.20044.58.2.1.3.41.7Scalarpm10010mpAlmCfpTxHostLolread-onlycurrentClient Trscv Tx Host Loss Of Lock :This OID indicates of Loss of Lock is detected on the Client Trscv Tx Host interface <Help> Alarm indicating of Loss of Lock…
1.3.6.1.4.1.20044.58.2.1.3.41.8Scalarpm10010mpAlmCfpTxLosfread-onlycurrentClient Trscv Loss Of Signal Functionality :This OID indicates a Loss of Signal functionality is detected on the Client Trscv <Help> Alarm indicating a Loss of …
1.3.6.1.4.1.20044.58.2.1.3.41.9Scalarpm10010mpAlmCfpTxCmuLolread-onlycurrentClient Trscv CMU Loss Of Lock :This OID indicates a Clock Multiplier Unit Loss of Lock is detected on the Client Trscv <Help> Alarm indicating a Clock Multipli…
1.3.6.1.4.1.20044.58.2.1.3.41.10Scalarpm10010mpAlmCfpTxJitterPllLolread-onlycurrentClient Trscv Tx Jitter PLL Loss Of Lock :This OID indicates a Tx Jitter PLL Loss of Lock is dtected on the Client Trscv <Help> Alarm indicating a Tx Jitter PLL…
1.3.6.1.4.1.20044.58.2.1.3.41.11Scalarpm10010mpAlmCfpLossOfRefclkread-onlycurrentClient Trscv Loss Of Ref Clock :This OID indicates a Loss of Reference clock is detected on the Client Trscv <Help> Alarm indicating a Loss of Reference clock …
1.3.6.1.4.1.20044.58.2.1.3.41.14Scalarpm10010mpAlmCfpHwInterlockread-onlycurrentClient Trscv Hardware Interlock :This OID indicates the Client Trscv power is higher than the cooling capacity <Help> Alarm indicating the Client Trscv power i…
1.3.6.1.4.1.20044.58.2.1.3.42Nodepm10010mpAlmclientGlobalAlarmSummary
1.3.6.1.4.1.20044.58.2.1.3.42.1Scalarpm10010mpAlmCfpSoftGlobAlarmTestread-onlycurrentClient Trscv Global Alarm SW Test :This OID indicates the Client Trscv Global Alarm This OID is raised by SW request for test purpose <Help> Status indicating …
1.3.6.1.4.1.20044.58.2.1.3.42.7Scalarpm10010mpAlmCfpNetworkLaneAlarmWarning2read-onlycurrentClient Trscv Network Alarm And Warning 2 :This OID indicates at least one DDM is detected on the Client Trscv Network Interface <Help> Synthesis alarm indicati…
1.3.6.1.4.1.20044.58.2.1.3.42.8Scalarpm10010mpAlmCfpModuleStateread-onlycurrentClient Trscv Module State :This OID indicates the Client Trscv module state <Help> Synthesis alarm indicating the Client Trscv module state <Condtype> CFP_MODU…
1.3.6.1.4.1.20044.58.2.1.3.42.9Scalarpm10010mpAlmCfpModuleGeneralStatusread-onlycurrentClient Trscv General Status :This OID indicates the Client Trscv module general status <Help> Synthesis alarm indicating the Client Trscv module general status…
1.3.6.1.4.1.20044.58.2.1.3.42.10Scalarpm10010mpAlmCfpModuleFaultread-onlycurrentClient Trscv Module Fault :This OID indicates at least one Fault is detected on the Client Trscv module <Help> Synthesis alarm indicating at least one Fault is…
1.3.6.1.4.1.20044.58.2.1.3.42.11Scalarpm10010mpAlmCfpModuleAlarmWarning1read-onlycurrentClient Trscv Module Alarm And Warning 1 :This OID indicates at least one DDM This OID is detected on the Client Trscv module <Help> Synthesis alarm indicating …
1.3.6.1.4.1.20044.58.2.1.3.42.12Scalarpm10010mpAlmCfpModuleAlarmWarning2read-onlycurrentClient Trscv Module Alarm And Warning 2 :This OID indicates at least one DDM is detected on the Client Trscv module <Help> Synthesis alarm indicating at least …
1.3.6.1.4.1.20044.58.2.1.3.42.13Scalarpm10010mpAlmCfpNetworkLaneAlarmWarning1read-onlycurrentClient Trscv Network Alarm And Warning 1 :This OID indicates at least one DDM is detected on the Client Trscv Network Interface <Help> Synthesis alarm indicati…
1.3.6.1.4.1.20044.58.2.1.3.42.14Scalarpm10010mpAlmCfpNetworkLaneFaultStatusread-onlycurrentClient Trscv Network Fault And Status :This OID indicates at least one Fault or Status is detected on the Client Trscv Network Interface <Help> Synthesis alarm…
1.3.6.1.4.1.20044.58.2.1.3.42.15Scalarpm10010mpAlmCfpHostLaneFaultStatusread-onlycurrentClient Trscv Host Fault And Status :This OID indicates at least one Fault or Status is detected on the Client Trscv Host Interface <Help> Synthesis alarm indic…
1.3.6.1.4.1.20044.58.2.1.3.42.16Scalarpm10010mpAlmCfpGlobAlarmAssertionread-onlycurrentClient Trscv Global Alarm :This OID indicates at least one Fault or Status is detected on the Client Trscv module <Help> Synthesis alarm indicating at least on…
1.3.6.1.4.1.20044.58.2.1.3.46Nodepm10010mpAlmmsaModuleState
1.3.6.1.4.1.20044.58.2.1.3.46.1Scalarpm10010mpAlmMsaInitializeread-onlycurrentLine Trscv Initialize :This OID indicates the Line Trscv initialization is in progress <Help> Status indicating the Line Trscv initialization is in progress <C…
1.3.6.1.4.1.20044.58.2.1.3.46.2Scalarpm10010mpAlmMsaLowPowerread-onlycurrentLine Trscv Low Power :This OID indicates the Line Trscv is in low power state <Help> Status indicating the Line Trscv is in low power state <Condtype> MSA_LOW_…
1.3.6.1.4.1.20044.58.2.1.3.46.3Scalarpm10010mpAlmMsaHighPowerUpread-onlycurrentLine Trscv High Power Up :This OID indicates the Line Trscv is leaving Low Power state <Help> Status indicating the Line Trscv is leaving Low Power state <Cond…
1.3.6.1.4.1.20044.58.2.1.3.46.4Scalarpm10010mpAlmMsaTxOffread-onlycurrentLine Trscv Laser Shutdown :This OID indicates the Line Trscv Laser is OFF <Help> Status indicating the Line Trscv Laser is OFF <Condtype> MSA_TX_OFF <Probcause…
1.3.6.1.4.1.20044.58.2.1.3.46.5Scalarpm10010mpAlmMsaTxTurnOnread-onlycurrentLine Trscv Laser Turn On :This OID indicates the Line Trscv is turning on its laser <Help> Status indicating the Line Trscv is turning on its laser <Condtype> …
1.3.6.1.4.1.20044.58.2.1.3.46.6Scalarpm10010mpAlmMsaReadyread-onlycurrentLine Trscv Ready :This OID indicates the Line Trscv is ready to operate <Help> Status indicating the Line Trscv is ready to operate <Condtype> MSA_READY <Probc…
1.3.6.1.4.1.20044.58.2.1.3.46.7Scalarpm10010mpAlmMsaFaultread-onlycurrentLine Trscv Fault :This OID indicates the Line Trscv is in Fault state <Help> Status indicating the Line Trscv is in Fault state <Condtype> MSA_FAULT <Probcause…
1.3.6.1.4.1.20044.58.2.1.3.46.8Scalarpm10010mpAlmMsaTxTurnOffread-onlycurrentLine Trscv Laser Turn Off :This OID indicates the Line Trscv is turning off its laser <Help> Status indicating the Line Trscv is turning off its laser <Condtyp…
1.3.6.1.4.1.20044.58.2.1.3.46.9Scalarpm10010mpAlmMsaHighPowerDownread-onlycurrentLine Trscv High Power Down :This OID indicates the Line Trscv is entering Low Power state <Help> Status indicating the Line Trscv is entering Low Power state <…
1.3.6.1.4.1.20044.58.2.1.3.47Nodepm10010mpAlmmsaModuleGeneralStatus
1.3.6.1.4.1.20044.58.2.1.3.47.4Scalarpm10010mpAlmMsaOutOfAlignmentread-onlycurrentLine Trscv Out Of Alignment :This OID indicates an Out of alignment on the Line Trscv Host Interface <Help> Alarm indicating an Out of alignment on the Line Tr…
1.3.6.1.4.1.20044.58.2.1.3.47.5Scalarpm10010mpAlmMsaRxNetworkLolread-onlycurrentLine Trscv Rx Network Loss Of Lock :This OID indicates of Loss of Lock is detected on the Line Trscv Rx Network interface <Help> Alarm indicating of Loss of Lo…
1.3.6.1.4.1.20044.58.2.1.3.47.6Scalarpm10010mpAlmMsaRxLosread-onlycurrentLine Trscv Loss Of Signal :This OID indicates a Loss of Signal is detected on the Line Trscv <Help> Alarm indicating a Loss of Signal is detected on the Line T…
1.3.6.1.4.1.20044.58.2.1.3.47.7Scalarpm10010mpAlmMsaTxHostLolread-onlycurrentLine Trscv Tx Host Loss Of Lock :This OID indicates of Loss of Lock is detected on the Line Trscv Tx Host interface <Help> Alarm indicating of Loss of Lock is …
1.3.6.1.4.1.20044.58.2.1.3.47.8Scalarpm10010mpAlmMsaTxLosfread-onlycurrentLine Trscv Loss Of Signal Functionality :This OID indicates a Loss of Signal functionality is detected on the Line Trscv <Help> Alarm indicating a Loss of Sign…
1.3.6.1.4.1.20044.58.2.1.3.47.9Scalarpm10010mpAlmMsaTxCmuLolread-onlycurrentLine Trscv CMU Loss Of Lock :This OID indicates a Clock Multiplier Unit Loss of Lock is detected on the Line Trscv <Help> Alarm indicating a Clock Multiplier U…
1.3.6.1.4.1.20044.58.2.1.3.47.10Scalarpm10010mpAlmMsaTxJitterPllLolread-onlycurrentLine Trscv Tx Jitter PLL Loss Of Lock :This OID indicates a Tx Jitter PLL Loss of Lock is detected on the Line Trscv <Help> Alarm indicating a Tx Jitter PLL Lo…
1.3.6.1.4.1.20044.58.2.1.3.47.11Scalarpm10010mpAlmMsaLossOfRefclkread-onlycurrentLine Trscv Loss Of Ref Clock :This OID indicates a Loss of Reference clock is detected on the Line Trscv <Help> Alarm indicating a Loss of Reference clock is d…
1.3.6.1.4.1.20044.58.2.1.3.47.14Scalarpm10010mpAlmMsaHwInterlockread-onlycurrentLine Trscv Hardware Interlock :This OID indicates the Line Trscv power is higher than the cooling capacity <Help> Alarm indicating the Line Trscv power is high…
1.3.6.1.4.1.20044.58.2.1.3.48Nodepm10010mpAlmmsaGlobalAlarmSummary
1.3.6.1.4.1.20044.58.2.1.3.48.1Scalarpm10010mpAlmMsaSoftGlobAlarmTestread-onlycurrentLine Trscv Global Alarm SW Test :This OID indicates the Line Trscv Global alarm This OID is raised by SW request for test purpose <Help> Status indicating the …
1.3.6.1.4.1.20044.58.2.1.3.48.6Scalarpm10010mpAlmMsaNetworkHostAlarmStatusread-onlycurrentLine Trscv Network/Host Alarm Status :This OID indicates the state of the Network and Host interface of the Line Trscv <Help> Synthesis alarm indicating the al…
1.3.6.1.4.1.20044.58.2.1.3.48.7Scalarpm10010mpAlmMsaNetworkLaneAlarmWarning2read-onlycurrentLine Trscv Network Alarm And Warning 2 :This OID indicates at least one DDM This OID is detected on the Line Trscv Network Interface <Help> Synthesis alarm ind…
1.3.6.1.4.1.20044.58.2.1.3.48.8Scalarpm10010mpAlmMsaModuleStateread-onlycurrentLine Trscv Module State :This OID indicates the Line Trscv module state <Help> Synthesis alarm indicating the Line Trscv module state <Condtype> MSA_MODULE_STA…
1.3.6.1.4.1.20044.58.2.1.3.48.9Scalarpm10010mpAlmMsaModuleGeneralStatusread-onlycurrentLine Trscv General Status :This OID indicates the Line Trscv module general <Help> Synthesis alarm indicating the Line Trscv module general status <Condtype> M…
1.3.6.1.4.1.20044.58.2.1.3.48.10Scalarpm10010mpAlmModuleFaultread-onlycurrentLine Trscv Module Fault :This OID indicates at least one Fault is detected on the Line Trscv module <Help> Synthesis alarm indicating at least one Fault is det…
1.3.6.1.4.1.20044.58.2.1.3.48.11Scalarpm10010mpAlmMsaModuleAlarmWarning1read-onlycurrentLine Trscv Module Alarm And Warning 1 :This OID indicates at least one DDM is detected on the Line Trscv module <Help> Synthesis alarm indicating at least one …
1.3.6.1.4.1.20044.58.2.1.3.48.12Scalarpm10010mpAlmMsaModuleAlarmWarning2read-onlycurrentLine Trscv Module Alarm And Warning 2 :This OID indicates at least one DDM is detected on the Line Trscv module <Help> Synthesis alarm indicating at least one …
1.3.6.1.4.1.20044.58.2.1.3.48.13Scalarpm10010mpAlmMsaNetworkLaneAlarmWarning1read-onlycurrentLine Trscv Network Alarm And Warning 1 :This OID indicates at least one DDM is detected on the Line Trscv Network Interface <Help> Synthesis alarm indicating a…
1.3.6.1.4.1.20044.58.2.1.3.48.14Scalarpm10010mpAlmMsaNetworkLaneFaultStatusread-onlycurrentLine Trscv Network Fault And Status :This OID indicates at least one Fault or Status is detected on the Line Trscv Network Interface <Help> Synthesis alarm ind…
1.3.6.1.4.1.20044.58.2.1.3.48.15Scalarpm10010mpAlmMsaHostLaneFaultStatusread-onlycurrentLine Trscv Host Fault And Status :This OID indicates at least one Fault or Status is detected on the Line Trscv Host Interface <Help> Synthesis alarm indicatin…
1.3.6.1.4.1.20044.58.2.1.3.48.16Scalarpm10010mpAlmMsaGlobAlarmAssertionread-onlycurrentLine Trscv Global Alarm :This OID indicates at least one Fault or Status is detected on the Line Trscv module <Help> Synthesis alarm indicating at least one Al…
1.3.6.1.4.1.20044.58.2.1.3.49Nodepm10010mpAlmmsaNetworkTxAlignment
1.3.6.1.4.1.20044.58.2.1.3.49.12Scalarpm10010mpAlmNetTxTimingFaultread-onlycurrentLine Trscv Network Tx Timing Fault :This OID indicates a Tx Timing Fault is detected on the Line Trscv Network interface <Help> Alarm indicating a Tx Timing Fa…
1.3.6.1.4.1.20044.58.2.1.3.49.13Scalarpm10010mpAlmNetTxReferenceClockFaultread-onlycurrentLine Trscv Network Tx Ref Clock Fault :This OID indicates a Tx Reference Clock Fault is detected on the Line Trscv Network interface <Help> Alarm indicating a …
1.3.6.1.4.1.20044.58.2.1.3.49.14Scalarpm10010mpAlmNetTxCmuLockFaultread-onlycurrentLine Trscv Network Tx CMU Lock Fault :This OID indicates a Tx Clock Multiplier Unit Lock Fault is detected on the Line Trscv Network interface <Help> Alarm ind…
1.3.6.1.4.1.20044.58.2.1.3.49.15Scalarpm10010mpAlmNetTxOutOfAlignmentread-onlycurrentLine Trscv Network Tx Out Of Alignment :This OID indicates a Tx Out of Alignment is detected on the Line Trscv Network interface <Help> Alarm indicating a Tx O…
1.3.6.1.4.1.20044.58.2.1.3.49.16Scalarpm10010mpAlmNetTxLossOfAlignmentread-onlycurrentLine Trscv Network Tx Loss Of Alignment :This OID indicates a Tx Loss of Alignment is detected on the Line Trscv Network interface <Help> Alarm indicating a Tx…
1.3.6.1.4.1.20044.58.2.1.3.50Nodepm10010mpAlmmsaNetworkRxAlignment
1.3.6.1.4.1.20044.58.2.1.3.50.12Scalarpm10010mpAlmNetRxTimingFaultread-onlycurrentLine Trscv Network Rx Timing Fault :This OID indicates a Rx Timing Fault is detected on the Line Trscv Network interface <Help> Alarm indicating a Rx Timing Fa…
1.3.6.1.4.1.20044.58.2.1.3.50.13Scalarpm10010mpAlmNetRxOutOfAlignmentread-onlycurrentLine Trscv Network Rx Out Of Alignment :This OID indicates a Rx Out of Alignment is detected on the Line Trscv Network interface <Help> Alarm indicating a Rx O…
1.3.6.1.4.1.20044.58.2.1.3.50.14Scalarpm10010mpAlmNetRxLossOfAlignmentread-onlycurrentLine Trscv Network Rx Loss Of Alignment :This OID indicates a Rx Loss of Alignment is detected on the Line Trscv Network interface <Help> Alarm indicating a Rx…
1.3.6.1.4.1.20044.58.2.1.3.50.15Scalarpm10010mpAlmNetRxModemLockFaultread-onlycurrentLine Trscv Network Rx Modem Lock Fault :This OID indicates a Rx Modem Lock Fault is detected on the Line Trscv Network interface <Help> Alarm indicating a Rx M…
1.3.6.1.4.1.20044.58.2.1.3.50.16Scalarpm10010mpAlmNetRxModemSyncDetectFaultread-onlycurrentLine Trscv Network Rx Modem Sync Detect Fault :This OID indicates a Rx Modem Synchronisation Detection Fault is detected on the Line Trscv Network interface <H…
1.3.6.1.4.1.20044.58.2.1.3.51Nodepm10010mpAlmmsaNetworkHostNetworkAlarmSummary
1.3.6.1.4.1.20044.58.2.1.3.51.11Scalarpm10010mpAlmNetworkTxAlignmentread-onlycurrentLine Trscv Network Tx Alignment :This OID indicates a Tx Alignment Fault is detected on the Line Trscv Network interface <Help> Synthesis Alarm indicating a Tx…
1.3.6.1.4.1.20044.58.2.1.3.51.12Scalarpm10010mpAlmNetworkRxAlignmentread-onlycurrentLine Trscv Network Rx Alignment :This OID indicates a Rx Alignment Fault is detected on the Line Trscv Network interface <Help> Synthesis Alarm indicating a Rx…
1.3.6.1.4.1.20044.58.2.1.3.51.13Scalarpm10010mpAlmNetworkRxOtnread-onlycurrentLine Trscv Network Rx OTN :This OID indicates a Rx OTN Fault is detected on the Line Trscv Network interface <Help> Synthesis Alarm indicating a Rx OTN Fault i…
1.3.6.1.4.1.20044.58.2.1.3.51.14Scalarpm10010mpAlmHostRxAlignmentread-onlycurrentLine Trscv Host Rx Alignment :This OID indicates a Rx Alignment Fault is detected on the Line Trscv Host interface <Help> Synthesis Alarm indicating a Rx Align…
1.3.6.1.4.1.20044.58.2.1.3.51.15Scalarpm10010mpAlmHostTxAlignmentread-onlycurrentLine Trscv Host Tx Alignment :This OID indicates a Tx Alignment Fault is detected on the Line Trscv Host interface <Help> Synthesis Alarm indicating a Tx Align…
1.3.6.1.4.1.20044.58.2.1.3.51.16Scalarpm10010mpAlmHostTxOtnStatusread-onlycurrentLine Trscv Host Tx OTN :This OID indicates a Tx OTN Fault is detected on the Line Trscv Host interface <Help> Synthesis Alarm indicating a Tx OTN Fault is dete…
1.3.6.1.4.1.20044.58.2.1.3.52Nodepm10010mpAlmmsaHostTxAlignment
1.3.6.1.4.1.20044.58.2.1.3.52.13Scalarpm10010mpAlmHostTxDeskewLockFaultread-onlycurrentLine Trscv Host Tx Deskew Lock Fault :This OID indicates a Tx Deskew Lock Fault is detected on the Line Trscv Host interface <Help> Alarm indicating a Tx Deske…
1.3.6.1.4.1.20044.58.2.1.3.52.14Scalarpm10010mpAlmHostTxOutOfAlignmentread-onlycurrentLine Trscv Host Tx Out Of Alignment :This OID indicates a Tx Out of Alignment is detected on the Line Trscv Host interface <Help> Alarm indicating a Tx Out of …
1.3.6.1.4.1.20044.58.2.1.3.52.15Scalarpm10010mpAlmHostTxLossOfAlignmentread-onlycurrentLine Trscv Host Tx Loss Of Alignment :This OID indicates a Tx Loss of Alignment is detected on the Line Trscv Host interface <Help> Alarm indicating a Tx Loss …
1.3.6.1.4.1.20044.58.2.1.3.52.16Scalarpm10010mpAlmHostTxCdrLockFaultread-onlycurrentLine Trscv Host Tx CDR Lock Fault :This OID indicates a Tx Clock Data Recovery Lock Fault is detected on the Line Trscv Host interface <Help> Alarm indicating …
1.3.6.1.4.1.20044.58.2.1.3.53Nodepm10010mpAlmmsaHostRxAlignment
1.3.6.1.4.1.20044.58.2.1.3.53.14Scalarpm10010mpAlmHostRxCmuLockFaultread-onlycurrentLine Trscv Host Rx CMU Lock Fault :This OID indicates a Rx Clock Multiplier Unit Lock Fault is detected on the Line Trscv Host interface <Help> Alarm indicatin…
1.3.6.1.4.1.20044.58.2.1.3.53.15Scalarpm10010mpAlmHostRxOutOfAlignmentread-onlycurrentLine Trscv Host Rx Out Of Alignment :This OID indicates a Rx Out of Alignment is detected on the Line Trscv Host interface <Help> Alarm indicating a Rx Out of …
1.3.6.1.4.1.20044.58.2.1.3.53.16Scalarpm10010mpAlmHostRxLossOfAlignmentread-onlycurrentLine Trscv Host Rx Loss Of Alignment :This OID indicates a Rx Loss of Alignment is detected on the Line Trscv Host interface <Help> Alarm indicating a Rx Loss …
1.3.6.1.4.1.20044.58.2.2Nodepm10010mpAlmClient
1.3.6.1.4.1.20044.58.2.2.1Nodepm10010mpAlmClientNurg
1.3.6.1.4.1.20044.58.2.2.1.56Tablepm10010mpAlmclientNetworkLaneAlarmWarningTablenot-accessiblecurrentList of pm10010mpAlmclientNetworkLaneAlarmWarning Article
1.3.6.1.4.1.20044.58.2.2.1.56.1Rowpm10010mpAlmclientNetworkLaneAlarmWarningEntrynot-accessiblecurrentRow definition for the pm10010mpAlmclientNetworkLaneAlarmWarning table
1.3.6.1.4.1.20044.58.2.2.1.56.1.1Columnpm10010mpAlmclientNetworkLaneAlarmWarningIndexread-onlycurrentIndex definition for the pm10010mpAlmclientNetworkLaneAlarmWarning table
1.3.6.1.4.1.20044.58.2.2.1.56.1.2Columnpm10010mpAlmClientRxPowerLowAlarmPortnread-onlycurrentClient Trscv Rx Power Low Alarm :This OID indicates that the Trscv input power is lower than the threshold value written in the Trscv EEPROM <Help> Alarm indic…
1.3.6.1.4.1.20044.58.2.2.1.56.1.3Columnpm10010mpAlmClientRxPowerLowWarningPortnread-onlycurrentClient Trscv Rx Power Low Warning :This OID indicates that the Trscv input power is lower than the threshold value written in the Trscv EEPROM <Help> Warning i…
1.3.6.1.4.1.20044.58.2.2.1.56.1.4Columnpm10010mpAlmClientRxPowerHighWarningPortnread-onlycurrentClient Trscv Rx Power High Warning :This OID indicates that the Trscv input power is higher than the threshold value written in the Trscv EEPROM <Help> Warning…
1.3.6.1.4.1.20044.58.2.2.1.56.1.5Columnpm10010mpAlmClientRxPowerHighAlarmPortnread-onlycurrentClient Trscv Rx Power High Alarm :This OID indicates that the Trscv input power is higher than the threshold value written in the Trscv EEPROM <Help> Alarm ind…
1.3.6.1.4.1.20044.58.2.2.1.56.1.6Columnpm10010mpAlmLaserTempLowAlarmPortnread-onlycurrentClient Trscv Laser Temp Low Alarm :This OID indicates that the Trscv Laser Temperature is lower than the threshold value written in the Trscv EEPROM <Help> Ala…
1.3.6.1.4.1.20044.58.2.2.1.56.1.7Columnpm10010mpAlmClientLaserTempLowWarningPortnread-onlycurrentClient Trscv Laser Temp Low Warning :This OID indicates that the Trscv Laser Temperature is lower than the threshold value written in the Trscv EEPROM <Help> W…
1.3.6.1.4.1.20044.58.2.2.1.56.1.8Columnpm10010mpAlmClientLaserTempHighWarningPortnread-onlycurrentClient Trscv Laser Temp High Warning :This OID indicates that the Trscv Laser Temperature is higher than the threshold value written in the Trscv EEPROM <Help>…
1.3.6.1.4.1.20044.58.2.2.1.56.1.9Columnpm10010mpAlmClientLaserTempHighAlarmPortnread-onlycurrentClient Trscv Laser Temp High Alarm :This OID indicates that the Trscv Laser Temperature is higher than the threshold value written in the Trscv EEPROM <Help> A…
1.3.6.1.4.1.20044.58.2.2.1.56.1.10Columnpm10010mpAlmClientTxPowerLowAlarmPortnread-onlycurrentClient Trscv Tx Power Low Alarm :This OID indicates that the Trscv output power is lower than the threshold value written in the Trscv EEPROM <Help> Alarm indi…
1.3.6.1.4.1.20044.58.2.2.1.56.1.11Columnpm10010mpAlmClientTxPowerLowWarningPortnread-onlycurrentClient Trscv Tx Power Low Warning :This OID indicates that the Trscv output power is lower than the threshold value written in the Trscv EEPROM <Help> Warning …
1.3.6.1.4.1.20044.58.2.2.1.56.1.12Columnpm10010mpAlmClientTxPowerHighWarningPortnread-onlycurrentClient Trscv Tx Power High Warning :This OID indicates that the Trscv output power is higher than the threshold value written in the Trscv EEPROM <Help> Warnin…
1.3.6.1.4.1.20044.58.2.2.1.56.1.13Columnpm10010mpAlmClientTxPowerHighAlarmPortnread-onlycurrentClient Trscv Tx Power High Alarm :This OID indicates that the Trscv output power is higher than the threshold value written in the Trscv EEPROM <Help> Alarm in…
1.3.6.1.4.1.20044.58.2.2.1.56.1.14Columnpm10010mpAlmClientBiasLowAlarmPortnread-onlycurrentClient Trscv Bias Low Alarm :This OID indicates that the Trscv laser bias current is lower than the threshold value written in the Trscv EEPROM <Help> Alarm in…
1.3.6.1.4.1.20044.58.2.2.1.56.1.15Columnpm10010mpAlmClientBiasLowWarningPortnread-onlycurrentClient Trscv Bias Low Warning :This OID indicates that the Trscv laser bias current is lower than the threshold value written in the Trscv EEPROM <Help> Warnin…
1.3.6.1.4.1.20044.58.2.2.1.56.1.16Columnpm10010mpAlmClientBiasHighWarningPortnread-onlycurrentClient Trscv Bias High Warning :This OID indicates that the Trscv laser bias current is higher than the threshold value written in the Trscv EEPROM <Help> Warn…
1.3.6.1.4.1.20044.58.2.2.1.56.1.17Columnpm10010mpAlmClientBiasHighAlarmPortnread-onlycurrentClient Trscv Bias High Alarm :This OID indicates that the Trscv laser bias current is higher than the threshold value written in the Trscv EEPROM <Help> Alarm …
1.3.6.1.4.1.20044.58.2.2.1.232Tablepm10010mpAlmclientSfpWarnDdmTablenot-accessiblecurrentList of pm10010mpAlmclientSfpWarnDdm Article
1.3.6.1.4.1.20044.58.2.2.1.232.1Rowpm10010mpAlmclientSfpWarnDdmEntrynot-accessiblecurrentRow definition for the pm10010mpAlmclientSfpWarnDdm table
1.3.6.1.4.1.20044.58.2.2.1.232.1.1Columnpm10010mpAlmclientSfpWarnDdmIndexread-onlycurrentIndex definition for the pm10010mpAlmclientSfpWarnDdm table
1.3.6.1.4.1.20044.58.2.2.1.232.1.2Columnpm10010mpAlmTxPwLowWngPortnread-onlycurrentClient Trscv Tx Power Low Warning :This OID indicates that the Trscv output power is lower than the threshold value written in the Trscv EEPROM <Help> Warning …
1.3.6.1.4.1.20044.58.2.2.1.232.1.3Columnpm10010mpAlmTxPwrHighWngPortnread-onlycurrentClient Trscv Tx Power High Warning :This OID indicates that the Trscv output power is higher than the threshold value written in the Trscv EEPROM <Help> Warnin…
1.3.6.1.4.1.20044.58.2.2.1.232.1.4Columnpm10010mpAlmTxBiasLowWngPortnread-onlycurrentClient Trscv Bias Low Warning :This OID indicates that the Trscv laser bias current is lower than the threshold value written in the Trscv EEPROM <Help> Warnin…
1.3.6.1.4.1.20044.58.2.2.1.232.1.5Columnpm10010mpAlmTxBiasHighWngPortnread-onlycurrentClient Trscv Bias High Warning :This OID indicates that the Trscv laser bias current is higher than the threshold value written in the Trscv EEPROM <Help> Warn…
1.3.6.1.4.1.20044.58.2.2.1.232.1.6Columnpm10010mpAlmVccLowWngPortnread-onlycurrentClient Trscv Power Supply Low Warning :This OID indicates that the Trscv power supply is lower than the threshold value written in the Trscv EEPROM <Help> Warn…
1.3.6.1.4.1.20044.58.2.2.1.232.1.7Columnpm10010mpAlmVccHighWngPortnread-onlycurrentClient Trscv Power Supply High Warning :This OID indicates that the Trscv power supply is higher than the threshold value written in the Trscv EEPROM <Help> Wa…
1.3.6.1.4.1.20044.58.2.2.1.232.1.8Columnpm10010mpAlmTempLowWngPortnread-onlycurrentClient Trscv Temp Low Warning :This OID indicates that the Trscv temperature is lower than the threshold value written in the Trscv EEPROM <Help> Warning indic…
1.3.6.1.4.1.20044.58.2.2.1.232.1.9Columnpm10010mpAlmTempHighWngPortnread-onlycurrentClient Trscv Temp High Warning :This OID indicates that the Trscv temperature is higher than the threshold value written in the Trscv EEPROM <Help> Warning ind…
1.3.6.1.4.1.20044.58.2.2.1.232.1.16Columnpm10010mpAlmRxPwrLowWngPortnread-onlycurrentClient Trscv Rx Power Low Warning :This OID indicates that the Trscv input power is lower than the threshold value written in the Trscv EEPROM <Help> Warning i…
1.3.6.1.4.1.20044.58.2.2.1.232.1.17Columnpm10010mpAlmRxPwrHighWngPortnread-onlycurrentClient Trscv Rx Power High Warning :This OID indicates that the Trscv input power is higher than the threshold value written in the Trscv EEPROM <Help> Warning…
1.3.6.1.4.1.20044.58.2.2.2Nodepm10010mpAlmClientUrg
1.3.6.1.4.1.20044.58.2.2.2.72Tablepm10010mpAlmclientNetworkLaneFaultTablenot-accessiblecurrentList of pm10010mpAlmclientNetworkLaneFault Article
1.3.6.1.4.1.20044.58.2.2.2.72.1Rowpm10010mpAlmclientNetworkLaneFaultEntrynot-accessiblecurrentRow definition for the pm10010mpAlmclientNetworkLaneFault table
1.3.6.1.4.1.20044.58.2.2.2.72.1.1Columnpm10010mpAlmclientNetworkLaneFaultIndexread-onlycurrentIndex definition for the pm10010mpAlmclientNetworkLaneFault table
1.3.6.1.4.1.20044.58.2.2.2.72.1.4Columnpm10010mpAlmClientLaneRxFifoErrorPortnread-onlycurrentClient Network Lane Rx FIFO Error :This OID indicates a Rx FIFO Error on the Client Trscv Network Lane <Help> Alarm indicating a Rx FIFO Error on the Client Tr…
1.3.6.1.4.1.20044.58.2.2.2.72.1.5Columnpm10010mpAlmClientLaneRxLolPortnread-onlycurrentClient Network Lane Rx Loss Of Lock :This OID indicates a Rx Loss of Lock on the Client Trscv Network Lane <Help> Alarm indicating a Rx Loss of Lock on the Cli…
1.3.6.1.4.1.20044.58.2.2.2.72.1.6Columnpm10010mpAlmClientLaneRxLosPortnread-onlycurrentClient Network Lane Rx Loss Of Signal :This OID indicates a Rx Loss of Signal on the Client Trscv Network Lane <Help> Alarm indicating a Rx Loss of Signal on t…
1.3.6.1.4.1.20044.58.2.2.2.72.1.8Columnpm10010mpAlmClientLaneTxLolPortnread-onlycurrentClient Network Lane Tx Loss Of Lock :This OID indicates a Tx Loss of Lock on the Client Trscv Network Lane <Help> Alarm indicating a Tx Loss of Lock on the Cli…
1.3.6.1.4.1.20044.58.2.2.2.72.1.9Columnpm10010mpAlmClientLaneTxLosfPortnread-onlycurrentClient Network Lane Tx Loss Of Signal Functionality :This OID indicates a Tx Loss of Signal Functionality on the Client Trscv Network Lane <Help> Alarm indicat…
1.3.6.1.4.1.20044.58.2.2.2.72.1.15Columnpm10010mpAlmClientLaneApdPowerSupplyPortnread-onlycurrentClient Network Lane APD Power Supply :This OID indicates an APD Power supply failure on the Client Trscv Network Lane <Help> Alarm indicating an APD Power supp…
1.3.6.1.4.1.20044.58.2.2.2.72.1.16Columnpm10010mpAlmClientLaneWavelengthUnlockedPortnread-onlycurrentClient Network Lane Wavelength Unlock :This OID indicates a Wavelength unlock on the Client Trscv Network Lane <Help> Alarm indicating a Wavelength unlock on t…
1.3.6.1.4.1.20044.58.2.2.2.72.1.17Columnpm10010mpAlmClientLaneTecFaultPortnread-onlycurrentClient Network Lane TEC Fault :This OID indicates a TEC Fault on the Client Trscv Network Lane <Help> Alarm indicating a TEC Fault on the Client Trscv Network …
1.3.6.1.4.1.20044.58.2.2.2.88Tablepm10010mpAlmclientHostLaneFaultTablenot-accessiblecurrentList of pm10010mpAlmclientHostLaneFault Article
1.3.6.1.4.1.20044.58.2.2.2.88.1Rowpm10010mpAlmclientHostLaneFaultEntrynot-accessiblecurrentRow definition for the pm10010mpAlmclientHostLaneFault table
1.3.6.1.4.1.20044.58.2.2.2.88.1.1Columnpm10010mpAlmclientHostLaneFaultIndexread-onlycurrentIndex definition for the pm10010mpAlmclientHostLaneFault table
1.3.6.1.4.1.20044.58.2.2.2.88.1.2Columnpm10010mpAlmClientLossOfSyncPortnread-onlycurrentClient Frame Alignment Loss :This OID indicates the module is not aligned with the incoming Client signal <Help> Alarm indicating the module is not aligned wit…
1.3.6.1.4.1.20044.58.2.2.2.88.1.3Columnpm10010mpAlmClientInputLossOfSigPortnread-onlycurrentClient Input Loss Of Signal :This OID indicates a Loss of Signal is detected on the Client Trscv <Help> Alarm indicating a Loss of Signal is detected on the Cl…
1.3.6.1.4.1.20044.58.2.2.2.88.1.4Columnpm10010mpAlmClientLanesMarkerUnlockPortnread-onlycurrentClient Lanes Marker Unlock :This OID indicates the Client lanes marker alignment is not lock <Help> Alarm indicating the Client lanes marker alignment is not l…
1.3.6.1.4.1.20044.58.2.2.2.88.1.5Columnpm10010mpAlmClientLanes6466UnlockPortnread-onlycurrentClient Lanes 64/66b Unlock :This OID indicates the Client 64/66b decoder is not lock <Help> Alarm indicating the Client 64/66b decoder is not lock <Condtype> C…
1.3.6.1.4.1.20044.58.2.2.2.88.1.6Columnpm10010mpAlmClientLanesNotAlignedPortnread-onlycurrentClient Lanes Not Aligned :This OID indicates the Client lanes are not aligned <Help> Alarm indicating the Client lanes are not aligned <Condtype> CLIENT_LANES_…
1.3.6.1.4.1.20044.58.2.2.2.88.1.7Columnpm10010mpAlmClientCsfDetectedPortnread-onlycurrentClient Signal Fail Detected :This OID indicates that a CSF has been detected on client port in the downstream direction <Help> This alarm indicates if a Client…
1.3.6.1.4.1.20044.58.2.2.2.88.1.10Columnpm10010mpAlmClientTxHostLolPortnread-onlycurrentClient Host Lane Tx Loss Of Lock :This OID indicates a Tx Loss of Lock on the Client Trscv Host Lane <Help> Alarm indicating a Tx Loss of Lock on the Client Tr…
1.3.6.1.4.1.20044.58.2.2.2.88.1.11Columnpm10010mpAlmClientLaneTxFifoErrorPortnread-onlycurrentClient Host Lane Tx FIFO Error :This OID indicates a Tx FIFO Error on the Client Trscv Host Lane <Help> Alarm indicating a Tx FIFO Error on the Client Trscv Ho…
1.3.6.1.4.1.20044.58.2.2.2.216Tablepm10010mpAlmclientSfpAlmDdmTablenot-accessiblecurrentList of pm10010mpAlmclientSfpAlmDdm Article
1.3.6.1.4.1.20044.58.2.2.2.216.1Rowpm10010mpAlmclientSfpAlmDdmEntrynot-accessiblecurrentRow definition for the pm10010mpAlmclientSfpAlmDdm table
1.3.6.1.4.1.20044.58.2.2.2.216.1.1Columnpm10010mpAlmclientSfpAlmDdmIndexread-onlycurrentIndex definition for the pm10010mpAlmclientSfpAlmDdm table
1.3.6.1.4.1.20044.58.2.2.2.216.1.2Columnpm10010mpAlmTxPwrLowAlaPortnread-onlycurrentClient Trscv Tx Power Low :This OID indicates that the Trscv output power of port is lower than the threshold value written in the Trscv EEPROM <Help> Alarm in…
1.3.6.1.4.1.20044.58.2.2.2.216.1.3Columnpm10010mpAlmTxPwrHighAlaPortnread-onlycurrentClient Trscv Tx Power High :This OID indicates that the Trscv output power of port is higher than the threshold value written in the Trscv EEPROM <Help> Alarm …
1.3.6.1.4.1.20044.58.2.2.2.216.1.4Columnpm10010mpAlmTxBiasLowAlaPortnread-onlycurrentClient Trscv Bias Low :This OID indicates that the Trscv laser bias current of port is lower than the threshold value written in the Trscv EEPROM <Help> Alarm …
1.3.6.1.4.1.20044.58.2.2.2.216.1.5Columnpm10010mpAlmTxBiasHighAlaPortnread-onlycurrentClient Trscv Bias High :This OID indicates that the Trscv laser bias current of port is higher than the threshold value written in the Trscv EEPROM <Help> Alar…
1.3.6.1.4.1.20044.58.2.2.2.216.1.6Columnpm10010mpAlmVccLowAlaPortnread-onlycurrentClient Trscv Power Supply Low :This OID indicates that the Trscv power supply of port is lower than the threshold value written in the Trscv EEPROM <Help> Alar…
1.3.6.1.4.1.20044.58.2.2.2.216.1.7Columnpm10010mpAlmVccHighAlaPortnread-onlycurrentClient Trscv Power Supply High :This OID indicates that the Trscv power supply of port is higher than the threshold value written in the Trscv EEPROM <Help> Al…
1.3.6.1.4.1.20044.58.2.2.2.216.1.8Columnpm10010mpAlmTempLowAlaPortnread-onlycurrentClient Trscv Temp Low :This OID indicates that the Trscv temperature of port is lower than the threshold value written in the Trscv EEPROM <Help> Alarm indicat…
1.3.6.1.4.1.20044.58.2.2.2.216.1.9Columnpm10010mpAlmTempHighAlaPortnread-onlycurrentClient Trscv Temp High :This OID indicates that the Trscv temperature of port is higher than the threshold value written in the Trscv EEPROM <Help> Alarm indic…
1.3.6.1.4.1.20044.58.2.2.2.216.1.16Columnpm10010mpAlmRxPwrLowAlaPortnread-onlycurrentClient Trscv Rx Power Low :This OID indicates that the Trscv input power of port is lower than the threshold value written in the Trscv EEPROM <Help> Alarm ind…
1.3.6.1.4.1.20044.58.2.2.2.216.1.17Columnpm10010mpAlmRxPwrHighAlaPortnread-onlycurrentClient Trscv Rx Power High :This OID indicates that the Trscv input power of port is higher than the threshold value written in the Trscv EEPROM <Help> Alarm i…
1.3.6.1.4.1.20044.58.2.2.3Nodepm10010mpAlmClientCrit
1.3.6.1.4.1.20044.58.2.2.3.8Tablepm10010mpAlmsynthAlmPortTablenot-accessiblecurrentList of pm10010mpAlmsynthAlmPort Article
1.3.6.1.4.1.20044.58.2.2.3.8.1Rowpm10010mpAlmsynthAlmPortEntrynot-accessiblecurrentRow definition for the pm10010mpAlmsynthAlmPort table
1.3.6.1.4.1.20044.58.2.2.3.8.1.1Columnpm10010mpAlmsynthAlmPortIndexread-onlycurrentIndex definition for the pm10010mpAlmsynthAlmPort table
1.3.6.1.4.1.20044.58.2.2.3.8.1.2Columnpm10010mpAlmSfpAbsentPortnread-onlycurrentClient Optical Module Absent :This OID indicates that the Transceiver is not present in the client port. <Help> This alarm indicates if the client transceiver …
1.3.6.1.4.1.20044.58.2.2.3.8.1.3Columnpm10010mpAlmDdmAbsentPortnread-onlycurrentDDM Supported On Client Trscv :This OID indicates that the Client transceiver supports the Digital Diagnostic Monitoring function <Help> This status indicates …
1.3.6.1.4.1.20044.58.2.2.3.8.1.5Columnpm10010mpAlmHwFailAccPortnread-onlycurrentClient HW Fail :This OID indicates a failure on client port, most probably caused by a HW issue. <Help> This alarm indicates a failure on client port, most pro…
1.3.6.1.4.1.20044.58.2.2.3.8.1.6Columnpm10010mpAlmDwLsdPortnread-onlycurrentClient Trscv Laser Shutdown :This OID indicates the Client transceiver laser is shutdown <Help> This status indicates if the client transceiver laser is shutdo…
1.3.6.1.4.1.20044.58.2.2.3.8.1.7Columnpm10010mpAlmClientLocalOosPortnread-onlycurrentLocal Client Port In Service :This OID indicates that the local Client port is In Service (1) or Out of Service (2) <Help> This status indicates if the local c…
1.3.6.1.4.1.20044.58.2.2.3.8.1.8Columnpm10010mpAlmClientRemoteOosPortnread-onlycurrentRemote Client Port In Service :This OID indicates that the remote Client port is In Service (1) or Out of Service (2) <Help> This status indicates if the remot…
1.3.6.1.4.1.20044.58.2.2.3.8.1.9Columnpm10010mpAlmDwCaisPortnread-onlycurrentClient AIS Inserted :This OID indicates a CAIS has been inserted on the output client port. <Help> This status indicates if a Client Alarm Indication Signal is…
1.3.6.1.4.1.20044.58.2.2.3.8.1.10Columnpm10010mpAlmSfpDdmWarningPortnread-onlycurrentWarning On Client Trscv DDM :This OID indicates a warning is being received from the Client Transceiver DDM <Help> This alarm indicates if a DDM Warning has be…
1.3.6.1.4.1.20044.58.2.2.3.8.1.11Columnpm10010mpAlmSfpDdmAlmPortnread-onlycurrentAlarm On Client Trscv DDM :This OID indicates an alarm is being received from the Client Transceiver DDM <Help> This alarm indicates if a DDM Alarm has been de…
1.3.6.1.4.1.20044.58.2.2.3.8.1.13Columnpm10010mpAlmFailAccPortnread-onlycurrentClient Access Fail :This OID indicates a failure on the Client port <Help> This alarm indicates a failure on the Client port <Condtype> FAIL_ACC_1 <Probcause> …
1.3.6.1.4.1.20044.58.2.2.3.8.1.17Columnpm10010mpAlmUpCsfPortnread-onlycurrentClient Signal Fail Inserted :This OID indicates a CSF has been inserted in the upstream client port. <Help> This status indicates if a Client Signal Fail is cu…
1.3.6.1.4.1.20044.58.2.3Nodepm10010mpAlmLine
1.3.6.1.4.1.20044.58.2.3.1Nodepm10010mpAlmLineNurg
1.3.6.1.4.1.20044.58.2.3.1.104Tablepm10010mpAlmlineNetworkLaneAlarmWarning1Tablenot-accessiblecurrentList of pm10010mpAlmlineNetworkLaneAlarmWarning1 Article
1.3.6.1.4.1.20044.58.2.3.1.104.1Rowpm10010mpAlmlineNetworkLaneAlarmWarning1Entrynot-accessiblecurrentRow definition for the pm10010mpAlmlineNetworkLaneAlarmWarning1 table
1.3.6.1.4.1.20044.58.2.3.1.104.1.1Columnpm10010mpAlmlineNetworkLaneAlarmWarning1Indexread-onlycurrentIndex definition for the pm10010mpAlmlineNetworkLaneAlarmWarning1 table
1.3.6.1.4.1.20044.58.2.3.1.104.1.2Columnpm10010mpAlmLineRxPowerLowAlarmPortnread-onlycurrentLine Trscv Rx Power Low Alarm :This OID indicates that the Trscv input power is lower than the threshold value written in the Trscv EEPROM <Help> Alarm indicat…
1.3.6.1.4.1.20044.58.2.3.1.104.1.3Columnpm10010mpAlmLineRxPowerLowWarningPortnread-onlycurrentLine Trscv Rx Power Low Warning :This OID indicates that the Trscv input power is lower than the threshold value written in the Trscv EEPROM <Help> Warning ind…
1.3.6.1.4.1.20044.58.2.3.1.104.1.4Columnpm10010mpAlmLineRxPowerHighWarningPortnread-onlycurrentLine Trscv Rx Power High Warning :This OID indicates that the Trscv input power is higher than the threshold value written in the Trscv EEPROM <Help> Warning i…
1.3.6.1.4.1.20044.58.2.3.1.104.1.5Columnpm10010mpAlmLineRxPowerHighAlarmPortnread-onlycurrentLine Trscv Rx Power High Alarm :This OID indicates that the Trscv input power is higher than the threshold value written in the Trscv EEPROM <Help> Alarm indic…
1.3.6.1.4.1.20044.58.2.3.1.104.1.6Columnpm10010mpAlmLineLaserTempLowAlarmPortnread-onlycurrentLine Trscv Tx Laser Temp Low Alarm :This OID indicates that the Trscv Tx Laser Temperature is lower than the threshold value written in the Trscv EEPROM <Help>…
1.3.6.1.4.1.20044.58.2.3.1.104.1.7Columnpm10010mpAlmLineLaserTempLowWarningPortnread-onlycurrentLine Trscv Tx Laser Temp Low Warning :This OID indicates that the Trscv Tx Laser Temperature is lower than the threshold value written in the Trscv EEPROM <Hel…
1.3.6.1.4.1.20044.58.2.3.1.104.1.8Columnpm10010mpAlmLineLaserTempHighWarningPortnread-onlycurrentLine Trscv Tx Laser Temp High Warning :This OID indicates that the Trscv Tx Laser Temperature is higher than the threshold value written in the Trscv EEPROM <H…
1.3.6.1.4.1.20044.58.2.3.1.104.1.9Columnpm10010mpAlmLineLaserTempHighAlarmPortnread-onlycurrentLine Trscv Tx Laser Temp High Alarm :This OID indicates that the Trscv Tx Laser Temperature is higher than the threshold value written in the Trscv EEPROM <Hel…
1.3.6.1.4.1.20044.58.2.3.1.104.1.10Columnpm10010mpAlmLineTxPowerLowAlarmPortnread-onlycurrentLine Trscv Tx Power Low Alarm :This OID indicates that the Trscv output power is lower than the threshold value written in the Trscv EEPROM <Help> Alarm indica…
1.3.6.1.4.1.20044.58.2.3.1.104.1.11Columnpm10010mpAlmLineTxPowerLowWarningPortnread-onlycurrentLine Trscv Tx Power Low Warning :This OID indicates that the Trscv output power is lower than the threshold value written in the Trscv EEPROM <Help> Warning in…
1.3.6.1.4.1.20044.58.2.3.1.104.1.12Columnpm10010mpAlmLineTxPowerHighWarningPortnread-onlycurrentLine Trscv Tx Power High Warning :This OID indicates that the Trscv output power is higher than the threshold value written in the Trscv EEPROM <Help> Warning …
1.3.6.1.4.1.20044.58.2.3.1.104.1.13Columnpm10010mpAlmLineTxPowerHighAlarmPortnread-onlycurrentLine Trscv Tx Power High Alarm :This OID indicates that the Trscv output power is higher than the threshold value written in the Trscv EEPROM <Help> Alarm indi…
1.3.6.1.4.1.20044.58.2.3.1.104.1.14Columnpm10010mpAlmLineBiasLowAlarmPortnread-onlycurrentLine Trscv Tx Bias Low Alarm :This OID indicates that the Trscv laser bias current is lower than the threshold value written in the Trscv EEPROM <Help> Alarm i…
1.3.6.1.4.1.20044.58.2.3.1.104.1.15Columnpm10010mpAlmLineBiasLowWarningPortnread-onlycurrentLine Trscv Tx Bias Low Warning :This OID indicates that the Trscv laser bias current is lower than the threshold value written in the Trscv EEPROM <Help> Warni…
1.3.6.1.4.1.20044.58.2.3.1.104.1.16Columnpm10010mpAlmLineBiasHighWarningPortnread-onlycurrentLine Trscv Tx Bias High Warning :This OID indicates that the Trscv laser bias current is higher than the threshold value written in the Trscv EEPROM <Help> War…
1.3.6.1.4.1.20044.58.2.3.1.104.1.17Columnpm10010mpAlmLineBiasHighAlarmPortnread-onlycurrentLine Trscv Tx Bias High Alarm :This OID indicates that the Trscv laser bias current is higher than the threshold value written in the Trscv EEPROM <Help> Alarm…
1.3.6.1.4.1.20044.58.2.3.1.120Tablepm10010mpAlmlineNetworkLaneAlarmWarning2Tablenot-accessiblecurrentList of pm10010mpAlmlineNetworkLaneAlarmWarning2 Article
1.3.6.1.4.1.20044.58.2.3.1.120.1Rowpm10010mpAlmlineNetworkLaneAlarmWarning2Entrynot-accessiblecurrentRow definition for the pm10010mpAlmlineNetworkLaneAlarmWarning2 table
1.3.6.1.4.1.20044.58.2.3.1.120.1.1Columnpm10010mpAlmlineNetworkLaneAlarmWarning2Indexread-onlycurrentIndex definition for the pm10010mpAlmlineNetworkLaneAlarmWarning2 table
1.3.6.1.4.1.20044.58.2.3.1.120.1.2Columnpm10010mpAlmTxModulatorBiasLowAlarmPortnread-onlycurrentLine Trscv Tx Modulator Bias Low Alarm :This OID indicates that the Trscv Tx modulator bias current is lower than the threshold value written in the Trscv EEPR…
1.3.6.1.4.1.20044.58.2.3.1.120.1.3Columnpm10010mpAlmTxModulatorBiasLowWarningPortnread-onlycurrentLine Trscv Tx Modulator Bias Low Warning :This OID indicates that the Trscv Tx modulator bias current is lower than the threshold value written in the Trscv EE…
1.3.6.1.4.1.20044.58.2.3.1.120.1.4Columnpm10010mpAlmTxModulatorBiasHighWarningPortnread-onlycurrentLine Trscv Tx Modulator Bias High Warning :This OID indicates that the Trscv Tx modulator bias current is higher than the threshold value written in the Trscv …
1.3.6.1.4.1.20044.58.2.3.1.120.1.5Columnpm10010mpAlmTxModulatorBiasHighAlarmPortnread-onlycurrentLine Trscv Tx Modulator Bias High Alarm :This OID indicates that the Trscv Tx modulator bias current is higher than the threshold value written in the Trscv EE…
1.3.6.1.4.1.20044.58.2.3.1.120.1.6Columnpm10010mpAlmRxLaserTempLowAlarmPortnread-onlycurrentLine Trscv Rx Laser Temp Low Alarm :This OID indicates that the Trscv Rx Laser Temperature is lower than the threshold value written in the Trscv EEPROM <Help>…
1.3.6.1.4.1.20044.58.2.3.1.120.1.7Columnpm10010mpAlmRxLaserTempLowWarningPortnread-onlycurrentLine Trscv Rx Laser Temp Low Warning :This OID indicates that the Trscv Rx Laser Temperature is lower than the threshold value written in the Trscv EEPROM <Hel…
1.3.6.1.4.1.20044.58.2.3.1.120.1.8Columnpm10010mpAlmRxLaserTempHighWarningPortnread-onlycurrentLine Trscv Rx Laser Temp High Warning :This OID indicates that the Trscv Rx Laser Temperature is higher than the threshold value written in the Trscv EEPROM <H…
1.3.6.1.4.1.20044.58.2.3.1.120.1.9Columnpm10010mpAlmRxLaserTempHighAlarmPortnread-onlycurrentLine Trscv Rx Laser Temp High Alarm :This OID indicates that the Trscv Rx Laser Temperature is higher than the threshold value written in the Trscv EEPROM <Hel…
1.3.6.1.4.1.20044.58.2.3.1.120.1.10Columnpm10010mpAlmRxLaserOutputLowAlarmPortnread-onlycurrentLine Trscv Rx Output Power Low Alarm :This OID indicates that the Trscv Rx output power is lower than the threshold value written in the Trscv EEPROM <Help> Al…
1.3.6.1.4.1.20044.58.2.3.1.120.1.11Columnpm10010mpAlmRxLaserOutputLowWarningPortnread-onlycurrentLine Trscv Rx Output Power Low Warning :This OID indicates that the Trscv Rx output power is lower than the threshold value written in the Trscv EEPROM <Help> …
1.3.6.1.4.1.20044.58.2.3.1.120.1.12Columnpm10010mpAlmRxLaserOutputHighWarningPortnread-onlycurrentLine Trscv Rx Output Power High Warning :This OID indicates that the Trscv Rx output power is higher than the threshold value written in the Trscv EEPROM <Help…
1.3.6.1.4.1.20044.58.2.3.1.120.1.13Columnpm10010mpAlmRxLaserOutputHighAlarmPortnread-onlycurrentLine Trscv Rx Output Power High Alarm :This OID indicates that the Trscv Rx output power is higher than the threshold value written in the Trscv EEPROM <Help> …
1.3.6.1.4.1.20044.58.2.3.1.120.1.14Columnpm10010mpAlmRxLaserBiasLowAlarmPortnread-onlycurrentLine Trscv Rx Bias Low Alarm :This OID indicates that the Trscv Rx laser bias current is lower than the threshold value written in the Trscv EEPROM <Help> Alar…
1.3.6.1.4.1.20044.58.2.3.1.120.1.15Columnpm10010mpAlmRxLaserBiasLowWarningPortnread-onlycurrentLine Trscv Rx Bias Low Warning :This OID indicates that the Trscv Rx laser bias current is lower than the threshold value written in the Trscv EEPROM <Help> Wa…
1.3.6.1.4.1.20044.58.2.3.1.120.1.16Columnpm10010mpAlmRxLaserBiasHighWarningPortnread-onlycurrentLine Trscv Rx Bias High Warning :This OID indicates that the Trscv Rx laser bias current is higher than the threshold value written in the Trscv EEPROM <Help> …
1.3.6.1.4.1.20044.58.2.3.1.120.1.17Columnpm10010mpAlmRxLaserBiasHighAlarmPortnread-onlycurrentLine Trscv Rx Bias High Alarm :This OID indicates that the Trscv Rx laser bias current is higher than the threshold value written in the Trscv EEPROM <Help> Al…
1.3.6.1.4.1.20044.58.2.3.2Nodepm10010mpAlmLineUrg
1.3.6.1.4.1.20044.58.2.3.2.136Tablepm10010mpAlmlineNetworkLaneFaultTablenot-accessiblecurrentList of pm10010mpAlmlineNetworkLaneFault Article
1.3.6.1.4.1.20044.58.2.3.2.136.1Rowpm10010mpAlmlineNetworkLaneFaultEntrynot-accessiblecurrentRow definition for the pm10010mpAlmlineNetworkLaneFault table
1.3.6.1.4.1.20044.58.2.3.2.136.1.1Columnpm10010mpAlmlineNetworkLaneFaultIndexread-onlycurrentIndex definition for the pm10010mpAlmlineNetworkLaneFault table
1.3.6.1.4.1.20044.58.2.3.2.136.1.3Columnpm10010mpAlmLineLaneRxTecFaultPortnread-onlycurrentLine Network Lane Rx TEC Fault :This OID indicates a Rx TEC Fault on the Line Trscv Network Lane <Help> Alarm indicating a Rx TEC Fault on the Line Trscv Netwo…
1.3.6.1.4.1.20044.58.2.3.2.136.1.4Columnpm10010mpAlmLineLaneRxFifoErrorPortnread-onlycurrentLine Network Lane Rx FIFO Error :This OID indicates a Rx FIFO Error on the Line Trscv Network Lane <Help> Alarm indicating a Rx FIFO Error on the Line Trscv Ne…
1.3.6.1.4.1.20044.58.2.3.2.136.1.5Columnpm10010mpAlmLineLaneRxLolPortnread-onlycurrentLine Network Lane Rx Loss Of Lock :This OID indicates a Rx Loss of Lock on the Line Trscv Network Lane <Help> Alarm indicating a Rx Loss of Lock on the Line Tr…
1.3.6.1.4.1.20044.58.2.3.2.136.1.6Columnpm10010mpAlmLineLaneRxLosPortnread-onlycurrentLine Network Lane Rx Loss Of Signal :This OID indicates a Rx Loss of Signal on the Line Trscv Network Lane <Help> Alarm indicating a Rx Loss of Signal on the L…
1.3.6.1.4.1.20044.58.2.3.2.136.1.8Columnpm10010mpAlmLineLaneTxLolPortnread-onlycurrentLine Network Lane Tx Loss Of Lock :This OID indicates a Tx Loss of Lock on the Line Trscv Network Lane <Help> Alarm indicating a Tx Loss of Lock on the Line Tr…
1.3.6.1.4.1.20044.58.2.3.2.136.1.9Columnpm10010mpAlmLineLaneTxLosfPortnread-onlycurrentLine Network Lane Tx Loss Of Signal Functionality :This OID indicates a Tx Loss of Signal Functionality on the Line Trscv Network Lane <Help> Alarm indicating …
1.3.6.1.4.1.20044.58.2.3.2.136.1.15Columnpm10010mpAlmLineLaneApdPowerSupplyPortnread-onlycurrentLine Network Lane APD Power Supply :This OID indicates an APD Power supply failure on the Line Trscv Network Lane <Help> Alarm indicating an APD Power supply f…
1.3.6.1.4.1.20044.58.2.3.2.136.1.16Columnpm10010mpAlmLineLaneWavelengthUnlockedPortnread-onlycurrentLine Network Lane Wavelength Unlock :This OID indicates a Wavelength unlock on the Line Trscv Network Lane <Help> Alarm indicating a Wavelength unlock on the L…
1.3.6.1.4.1.20044.58.2.3.2.136.1.17Columnpm10010mpAlmLineLaneTecFaultPortnread-onlycurrentLine Network Lane TEC Fault :This OID indicates a Tx TEC Fault on the Line Trscv Network Lane <Help> Alarm indicating a Tx TEC Fault on the Line Trscv Network …
1.3.6.1.4.1.20044.58.2.3.2.152Tablepm10010mpAlmlineHostLaneFaultTablenot-accessiblecurrentList of pm10010mpAlmlineHostLaneFault Article
1.3.6.1.4.1.20044.58.2.3.2.152.1Rowpm10010mpAlmlineHostLaneFaultEntrynot-accessiblecurrentRow definition for the pm10010mpAlmlineHostLaneFault table
1.3.6.1.4.1.20044.58.2.3.2.152.1.1Columnpm10010mpAlmlineHostLaneFaultIndexread-onlycurrentIndex definition for the pm10010mpAlmlineHostLaneFault table
1.3.6.1.4.1.20044.58.2.3.2.152.1.2Columnpm10010mpAlmLineInputLossOfSignalPortnread-onlycurrentLine Input Loss Of Signal :This OID indicates a Loss of Signal is detected on the Line Trscv <Help> Alarm indicating a Loss of Signal is detected on the Line T…
1.3.6.1.4.1.20044.58.2.3.2.152.1.3Columnpm10010mpAlmLineLossOfFramePortnread-onlycurrentLine Loss Of Frame :This OID indicates the module is not aligned with the incoming Line signal <Help> Alarm indicating the module is not aligned with the incom…
1.3.6.1.4.1.20044.58.2.3.2.152.1.4Columnpm10010mpAlmLineSmBdiInsertedPortnread-onlycurrentLine SM BDI Inserted :This OID indicates a SM Backward Defect Indication is inserted on the outgoing Line signal <Help> Status indicating a SM Backward Defect …
1.3.6.1.4.1.20044.58.2.3.2.152.1.5Columnpm10010mpAlmLineSmBdiDetectedPortnread-onlycurrentLine SM BDI Detected :This OID indicates a SM Backward Defect Indication is detected on the incoming Line signal <Help> Alarm indicating a SM Backward Defect I…
1.3.6.1.4.1.20044.58.2.3.2.152.1.6Columnpm10010mpAlmLineSmIaeInsertedPortnread-onlycurrentLine SM IAE Inserted :This OID indicates a SM Incoming Alignment Error is inserted on the outgoing Line signal <Help> Status indicating a SM Incoming Alignment…
1.3.6.1.4.1.20044.58.2.3.2.152.1.7Columnpm10010mpAlmLineSmIaeDetectedPortnread-onlycurrentLine SM IAE Detected :This OID indicates a SM Incoming Alignment Error is detected on the incoming Line signal <Help> Alarm indicating a SM Incoming Alignment …
1.3.6.1.4.1.20044.58.2.3.2.152.1.10Columnpm10010mpAlmLineTxHostLolPortnread-onlycurrentLine Host Lane Tx Loss Of Lock :This OID indicates a Tx Loss of Lock on the Line Trscv Host Lane <Help> Alarm indicating a Tx Loss of Lock on the Line Trscv Ho…
1.3.6.1.4.1.20044.58.2.3.2.152.1.11Columnpm10010mpAlmLineLaneTxFifoErrorPortnread-onlycurrentLine Host Lane Tx FIFO Error :This OID indicates a Tx FIFO Error on the Line Trscv Host Lane <Help> Alarm indicating a Tx FIFO Error on the Line Trscv Host Lan…
1.3.6.1.4.1.20044.58.2.3.2.168Tablepm10010mpAlmlineNetworkLaneRxOtnTablenot-accessiblecurrentList of pm10010mpAlmlineNetworkLaneRxOtn Article
1.3.6.1.4.1.20044.58.2.3.2.168.1Rowpm10010mpAlmlineNetworkLaneRxOtnEntrynot-accessiblecurrentRow definition for the pm10010mpAlmlineNetworkLaneRxOtn table
1.3.6.1.4.1.20044.58.2.3.2.168.1.1Columnpm10010mpAlmlineNetworkLaneRxOtnIndexread-onlycurrentIndex definition for the pm10010mpAlmlineNetworkLaneRxOtn table
1.3.6.1.4.1.20044.58.2.3.2.168.1.10Columnpm10010mpAlmLineRxOtnOduAisPortnread-onlycurrentLine Network Rx ODU AIS :This OID indicates an ODU This OID Indication Signal is detected on the Rx Network interface of the Line Trscv <Help> Alarm indicating…
1.3.6.1.4.1.20044.58.2.3.2.168.1.11Columnpm10010mpAlmLineRxOtnOtuAisPortnread-onlycurrentLine Network Rx OTU AIS :This OID indicates an OTU This OID Indication Signal is detected on the Rx Network interface of the Line Trscv <Help> Alarm indicating…
1.3.6.1.4.1.20044.58.2.3.2.168.1.12Columnpm10010mpAlmLineRxSmBdiPortnread-onlycurrentLine Network Rx SM BDI :This OID indicates an SM Backward Defect Indication is detected on the Rx Network interface of the Line Trscv <Help> Alarm indicating a…
1.3.6.1.4.1.20044.58.2.3.2.168.1.13Columnpm10010mpAlmLineRxOtnIaePortnread-onlycurrentLine Network Rx IAE :This OID indicates an Incoming Alignment Error is detected on the Rx Network interface of the Line Trscv <Help> Alarm indicating an Incomi…
1.3.6.1.4.1.20044.58.2.3.2.168.1.14Columnpm10010mpAlmLineRxOtnOomPortnread-onlycurrentLine Network Rx OOM :This OID indicates an Out of Multiframe is detected on the Rx Network interface of the Line Trscv <Help> Alarm indicating an Out of Multif…
1.3.6.1.4.1.20044.58.2.3.2.168.1.15Columnpm10010mpAlmLineRxOtnLomPortnread-onlycurrentLine Network Rx LOM :This OID indicates a Loss of Multiframe is detected on the Rx Network interface of the Line Trscv <Help> Alarm indicating a Loss of Multif…
1.3.6.1.4.1.20044.58.2.3.2.168.1.16Columnpm10010mpAlmLineRxOtnOofPortnread-onlycurrentLine Network Rx OOF :This OID indicates an Out of Frame is detected on the Rx Network interface of the Line Trscv <Help> Alarm indicating an Out of Frame is de…
1.3.6.1.4.1.20044.58.2.3.2.168.1.17Columnpm10010mpAlmLineRxOtnLofPortnread-onlycurrentLine Network Rx LOF :This OID indicates a Loss of Frame is detected on the Rx Network interface of the Line Trscv <Help> Alarm indicating a Loss of Frame is de…
1.3.6.1.4.1.20044.58.2.3.2.184Tablepm10010mpAlmlineHostLaneTxOtnTablenot-accessiblecurrentList of pm10010mpAlmlineHostLaneTxOtn Article
1.3.6.1.4.1.20044.58.2.3.2.184.1Rowpm10010mpAlmlineHostLaneTxOtnEntrynot-accessiblecurrentRow definition for the pm10010mpAlmlineHostLaneTxOtn table
1.3.6.1.4.1.20044.58.2.3.2.184.1.1Columnpm10010mpAlmlineHostLaneTxOtnIndexread-onlycurrentIndex definition for the pm10010mpAlmlineHostLaneTxOtn table
1.3.6.1.4.1.20044.58.2.3.2.184.1.10Columnpm10010mpAlmLineTxOtnOduAisPortnread-onlycurrentLine Host Tx ODU AIS :This OID indicates an ODU This OID Indication Signal is detected on the Tx Host interface of the Line Trscv <Help> Alarm indicating an OD…
1.3.6.1.4.1.20044.58.2.3.2.184.1.11Columnpm10010mpAlmLineTxOtnOtuAisPortnread-onlycurrentLine Host Tx OTU AIS :This OID indicates an OTU This OID Indication Signal is detected on the Tx Host interface of the Line Trscv <Help> Alarm indicating an OT…
1.3.6.1.4.1.20044.58.2.3.2.184.1.12Columnpm10010mpAlmLineTxSmBdiPortnread-onlycurrentLine Host Tx SM BDI :This OID indicates an SM Backward Defect Indication is detected on the Tx Host interface of the Line Trscv <Help> Alarm indicating an SM B…
1.3.6.1.4.1.20044.58.2.3.2.184.1.13Columnpm10010mpAlmLineTxOtnIaePortnread-onlycurrentLine Host Tx IAE :This OID indicates an Incoming Alignment Error is detected on the Tx Host interface of the Line Trscv <Help> Alarm indicating an Incoming Ali…
1.3.6.1.4.1.20044.58.2.3.2.184.1.14Columnpm10010mpAlmLineTxOtnOomPortnread-onlycurrentLine Host Tx OOM :This OID indicates an Out of Multiframe is detected on the Tx Host interface of the Line Trscv <Help> Alarm indicating an Out of Multiframe i…
1.3.6.1.4.1.20044.58.2.3.2.184.1.15Columnpm10010mpAlmLineTxOtnLomPortnread-onlycurrentLine Host Tx LOM :This OID indicates a Loss of Multiframe is detected on the Tx Host interface of the Line Trscv <Help> Alarm indicating a Loss of Multiframe i…
1.3.6.1.4.1.20044.58.2.3.2.184.1.16Columnpm10010mpAlmLineTxOtnOofPortnread-onlycurrentLine Host Tx OOF :This OID indicates an Out of Frame is detected on the Tx Host interface of the Line Trscv <Help> Alarm indicating an Out of Frame is detected…
1.3.6.1.4.1.20044.58.2.3.2.184.1.17Columnpm10010mpAlmLineTxOtnLofPortnread-onlycurrentLine Host Tx LOF :This OID indicates a Loss of Frame is detected on the Tx Host interface of the Line Trscv <Help> Alarm indicating a Loss of Frame is detected…
1.3.6.1.4.1.20044.58.2.3.3Nodepm10010mpAlmLineCrit
1.3.6.1.4.1.20044.58.2.3.3.24Tablepm10010mpAlmsynthAlmLineTablenot-accessiblecurrentList of pm10010mpAlmsynthAlmLine Article
1.3.6.1.4.1.20044.58.2.3.3.24.1Rowpm10010mpAlmsynthAlmLineEntrynot-accessiblecurrentRow definition for the pm10010mpAlmsynthAlmLine table
1.3.6.1.4.1.20044.58.2.3.3.24.1.1Columnpm10010mpAlmsynthAlmLineIndexread-onlycurrentIndex definition for the pm10010mpAlmsynthAlmLine table
1.3.6.1.4.1.20044.58.2.3.3.24.1.2Columnpm10010mpAlmXfpAbsentPortnread-onlycurrentLine Optical Module Absent :This OID indicates that the line optical interface is not present. <Help> This alarm indicates if the line transceiver is not plugg…
1.3.6.1.4.1.20044.58.2.3.3.24.1.3Columnpm10010mpAlmXfpInitNotComplPortnread-onlycurrentLine Optical Module Ready :This OID indicates that the optical interface is not operational. <Help> This status indicates if the line transceiver has been corr…
1.3.6.1.4.1.20044.58.2.3.3.24.1.5Columnpm10010mpAlmLineHwFailPortnread-onlycurrentLine Port HW Failure :This OID indicates a failure on line port, most probably caused by a HW issue <Help> This alarm indicates a failure on line port, most pr…
1.3.6.1.4.1.20044.58.2.3.3.24.1.6Columnpm10010mpAlmXfpTxOffPortnread-onlycurrentLine Trscv Laser Shutdown :This OID indicates the Line transceiver laser is shutdown <Help> This status indicates if the Line transceiver laser is shutdown <Co…
1.3.6.1.4.1.20044.58.2.3.3.24.1.7Columnpm10010mpAlmLineLocalOosPortnread-onlycurrentLine Port In Service :This OID indicates that the Line port is In Service (1) of Out or Service (2) <Help> This status indicates if the line port is in service…
1.3.6.1.4.1.20044.58.2.3.3.24.1.9Columnpm10010mpAlmUpRdiInsPortnread-onlycurrentMS-RDI/L-RDI Inserted On Line :This OID indicates an upstream MS-RDI/L-RDI has been inserted in the outgoing 10 Gb/s SDH/SONET signal. <Help> This status indic…
1.3.6.1.4.1.20044.58.2.3.3.24.1.10Columnpm10010mpAlmLineDdmWarningPortnread-onlycurrentWarning On Line Optical Module DDM :This OID indicates a warning is present coming out of Line transceiver DDM <Help> This alarm indicates if a DDM Warning has…
1.3.6.1.4.1.20044.58.2.3.3.24.1.11Columnpm10010mpAlmLineDdmAlmPortnread-onlycurrentAlarm On Line Optical Module DDM :This OID indicates an alarm is present coming out of Line transceiver DDM <Help> This alarm indicates if a DDM Alarm has been…
1.3.6.1.4.1.20044.58.2.3.3.24.1.13Columnpm10010mpAlmLineFailPortnread-onlycurrentLine Port Failure :This OID indicates a failure on the line port <Help> This alarm indicates a failure on the line port <Condtype> LINE_FAIL <Probcause> equipm…
1.3.6.1.4.1.20044.58.2.3.3.24.1.17Columnpm10010mpAlmLineActivePortnread-onlycurrentLine Active :This OID indicates whether the line is active or standby. <Help> This status indicates whether the line is active or standby. <Condtype> LINE_ACTI…
1.3.6.1.4.1.20044.58.3Nodepm10010mpmeasures
1.3.6.1.4.1.20044.58.3.1Nodepm10010mpMesrOther
1.3.6.1.4.1.20044.58.3.1.0Scalarpm10010mpMesrsynth0read-onlydeprecatedNot Used :
1.3.6.1.4.1.20044.58.3.1.1Scalarpm10010mpMesrsynth1read-onlydeprecatedNot Used :
1.3.6.1.4.1.20044.58.3.1.7Scalarpm10010mpMesrpmIntervalNumberread-onlycurrentPM Interval Counter :
1.3.6.1.4.1.20044.58.3.1.180Scalarpm10010mpMesrlineNetTxLaserOutputPwrAverageread-onlycurrentAverage Line Trscv Tx Power :This OID gives the average Tx Laser transmit power value among the network lanes of the Line Transceiver, read in the DDM (Digital…
1.3.6.1.4.1.20044.58.3.1.181Scalarpm10010mpMesrlineNetTxLaserTempAverageread-onlycurrentAverage Line Trscv Tx Laser Temperature :This OID gives the average Tx Laser Temperature value among the network lanes of the Line Transceiver, read from the D…
1.3.6.1.4.1.20044.58.3.1.182Scalarpm10010mpMesrlineNetTxBiasCurrentAverageread-onlycurrentAverage Line Trscv Tx Laser Bias :This OID gives the average Tx Laser Bias value among the network lanes of the Line Transceiver, read from the DDM (Digital Di…
1.3.6.1.4.1.20044.58.3.1.183Scalarpm10010mpMesrlineNetRxInputPwrAverageread-onlycurrentAverage Line Trscv Rx Power :This OID gives the average Receive power value among the network lanes of the Line Transceiver, read in the DDM (Digital Diagnosti…
1.3.6.1.4.1.20044.58.3.1.184Scalarpm10010mpMesrlineResidualChromaticDispAverageread-onlycurrentAverage Residual Chromatic Dispersion :This OID gives the average Residual Chromatic Dispersion on the Line interface since the last measure reset <Help> This …
1.3.6.1.4.1.20044.58.3.1.185Scalarpm10010mpMesrlineDiffGroupDelayAverageread-onlycurrentAverage Differential Group Delay :This OID gives the average Group Delay on the Line interface since the last measure reset <Help> This measure gives the avera…
1.3.6.1.4.1.20044.58.3.1.186Scalarpm10010mpMesrlineQFactorAverageread-onlycurrentAverage Q Factor :This OID gives the average Q Factor on the Line interface since the last measure reset <Help> This measure gives the average Q Factor on the …
1.3.6.1.4.1.20044.58.3.1.187Scalarpm10010mpMesrlineCarrierFreqOffsetAverageread-onlycurrentAverage Carrier Frequency Offset :This OID gives the average Carrier Frequency Offset on the Line interface since the last measure reset <Help> This measure gi…
1.3.6.1.4.1.20044.58.3.1.188Scalarpm10010mpMesrlineOsnrAverageread-onlycurrentAverage OSNR :This OID gives the average OSNR on the Line interface since the last measure reset <Help> This measure gives the average OSNR on the Line interfa…
1.3.6.1.4.1.20044.58.3.1.192Scalarpm10010mpMesrclientNetTxTempMinread-onlycurrentMin Client Trscv Laser Temperature :This OID gives the minimum Laser temperature value among the network lanes of the Client Transceiver, read from the DDM (Di…
1.3.6.1.4.1.20044.58.3.1.193Scalarpm10010mpMesrclientNetTxBiasMinread-onlycurrentMin Client Trscv Laser Bias :This OID gives the minimum Laser bias value among the network lanes of the Client Transceiver, read from the DDM (Digital Diagnost…
1.3.6.1.4.1.20044.58.3.1.194Scalarpm10010mpMesrclientNetTxPwrMinread-onlycurrentMin Client Trscv Tx Power :This OID gives the minimum transmit power value among the network lanes of the Client Transceiver, read from the DDM (Digital Diagno…
1.3.6.1.4.1.20044.58.3.1.195Scalarpm10010mpMesrclientNetRxPwrMinread-onlycurrentMin Client Trscv Rx Power :This OID gives the minimum receive power value among the network lanes of the Client Transceiver, read in the DDM (Digital Diagnosti…
1.3.6.1.4.1.20044.58.3.1.196Scalarpm10010mpMesrlineNetTxLaserOutputPwrMinread-onlycurrentMin Line Trscv Tx Power :This OID gives the minimum Tx Laser transmit power value among the network lanes of the Line Transceiver, read in the DDM (Digital Dia…
1.3.6.1.4.1.20044.58.3.1.197Scalarpm10010mpMesrlineNetTxLaserTempMinread-onlycurrentMin Line Trscv Tx Laser Temperature :This OID gives the minimum Tx Laser Temperature value among the network lanes of the Line Transceiver, read from the DDM (…
1.3.6.1.4.1.20044.58.3.1.198Scalarpm10010mpMesrlineNetTxBiasCurrentMinread-onlycurrentMin Line Trscv Tx Laser Bias :This OID gives the minimum Tx Laser Bias value among the network lanes of the Line Transceiver, read from the DDM (Digital Diagno…
1.3.6.1.4.1.20044.58.3.1.199Scalarpm10010mpMesrlineNetRxInputPwrMinread-onlycurrentMin Line Trscv Rx Power :This OID gives the minimum Receive power value among the network lanes of the Line Transceiver, read in the DDM (Digital Diagnostic Mo…
1.3.6.1.4.1.20044.58.3.1.200Scalarpm10010mpMesrlineResidualChromaticDispMinread-onlycurrentMin Residual Chromatic Dispersion :This OID gives the minimum Residual Chromatic Dispersion on the Line interface since the last measure reset (Unit = ps/nm)<H…
1.3.6.1.4.1.20044.58.3.1.201Scalarpm10010mpMesrlineDiffGroupDelayMinread-onlycurrentMin Differential Group Delay :This OID gives the minimum Differential Group Delay on the Line interface since the last measure reset (Unit = ps)<Help> This mea…
1.3.6.1.4.1.20044.58.3.1.202Scalarpm10010mpMesrlineQFactorMinread-onlycurrentMin Q Factor :This OID gives the minimum Q Factor on the Line interface since the last measure reset (Unit = dB)<Help> This measure gives the minimum Q Factor …
1.3.6.1.4.1.20044.58.3.1.203Scalarpm10010mpMesrlineCarrierFreqOffsetMinread-onlycurrentMin Carrier Frequency Offset :This OID gives the minimum Carrier Frequency Offset on the Line interface since the last measure reset (Unit = Mhz)<Help> This me…
1.3.6.1.4.1.20044.58.3.1.204Scalarpm10010mpMesrlineOsnrMinread-onlycurrentMin OSNR :This OID gives the minimum OSNR on the Line interface since the last measure reset (OSNR = AV/10) (Unit = dB)<Help> This measure gives the minimum OS…
1.3.6.1.4.1.20044.58.3.1.208Scalarpm10010mpMesrclientNetTxTempMaxread-onlycurrentMax Client Trscv Laser Temperature :This OID gives the maximum Laser temperature value among the network lanes of the Client Transceiver, read from the DDM (Di…
1.3.6.1.4.1.20044.58.3.1.209Scalarpm10010mpMesrclientNetTxBiasMaxread-onlycurrentMax Client Trscv Laser Bias :This OID gives the maximum Laser bias value among the network lanes of the Client Transceiver, read from the DDM (Digital Diagnost…
1.3.6.1.4.1.20044.58.3.1.210Scalarpm10010mpMesrclientNetTxPwrMaxread-onlycurrentMax Client Trscv Tx Power :This OID gives the maximum transmit power value among the network lanes of the Client Transceiver, read from the DDM (Digital Diagno…
1.3.6.1.4.1.20044.58.3.1.211Scalarpm10010mpMesrclientNetRxPwrMaxread-onlycurrentMax Client Trscv Rx Power :This OID gives the maximum receive power value among the network lanes of the Client Transceiver, read in the DDM (Digital Diagnosti…
1.3.6.1.4.1.20044.58.3.1.212Scalarpm10010mpMesrlineNetTxLaserOutputPwrMaxread-onlycurrentMax Line Trscv Tx Power :This OID gives the maximum Tx Laser transmit power value among the network lanes of the Line Transceiver, read in the DDM (Digital Dia…
1.3.6.1.4.1.20044.58.3.1.213Scalarpm10010mpMesrlineNetTxLaserTempMaxread-onlycurrentMax Line Trscv Tx Laser Temperature :This OID gives the maximum Tx Laser Temperature value among the network lanes of the Line Transceiver, read from the DDM (…
1.3.6.1.4.1.20044.58.3.1.214Scalarpm10010mpMesrlineNetTxBiasCurrentMaxread-onlycurrentMax Line Trscv Tx Laser Bias :This OID gives the maximum Tx Laser Bias value among the network lanes of the Line Transceiver, read from the DDM (Digital Diagno…
1.3.6.1.4.1.20044.58.3.1.215Scalarpm10010mpMesrlineNetRxInputPwrMaxread-onlycurrentMax Line Trscv Rx Power :This OID gives the maximum Receive power value among the network lanes of the Line Transceiver, read in the DDM (Digital Diagnostic Mo…
1.3.6.1.4.1.20044.58.3.1.216Scalarpm10010mpMesrlineResidualChromaticDispMaxread-onlycurrentMax Residual Chromatic Dispersion :This OID gives the maximum Residual Chromatic Dispersion on the Line interface since the last measure reset (Unit = ps/nm)<H…
1.3.6.1.4.1.20044.58.3.1.217Scalarpm10010mpMesrlineDiffGroupDelayMaxread-onlycurrentMax Differential Group Delay :This OID gives the maximum Differential Group Delay on the Line interface since the last measure reset (Unit = ps)<Help> This mea…
1.3.6.1.4.1.20044.58.3.1.218Scalarpm10010mpMesrlineQFactorMaxread-onlycurrentMax Q Factor :This OID gives the maximum Q Factor on the Line interface since the last measure reset (Unit = dB)<Help> This measure gives the maximum Q Factor …
1.3.6.1.4.1.20044.58.3.1.219Scalarpm10010mpMesrlineCarrierFreqOffsetMaxread-onlycurrentMax Carrier Frequency Offset :This OID gives the maximum Carrier Frequency Offset on the Line interface since the last measure reset (Unit = Mhz)<Help> This me…
1.3.6.1.4.1.20044.58.3.1.220Scalarpm10010mpMesrlineOsnrMaxread-onlycurrentMax OSNR :This OID gives the maximum OSNR on the Line interface since the last measure reset (OSNR = AV/10) (Unit = dB)<Help> This measure gives the maximum OS…
1.3.6.1.4.1.20044.58.3.2Nodepm10010mpMesrClient
1.3.6.1.4.1.20044.58.3.2.8Scalarpm10010mpMesrclientCfpTempread-onlycurrentClient Trscv Temperature :This OID gives the temperature value of the Client Transceiver, read from the DDM (Digital Diagnostic Monitoring) (Temperature = AV/2…
1.3.6.1.4.1.20044.58.3.2.9Scalarpm10010mpMesrclientCfp3v3Voltageread-onlycurrentClient Trscv Voltage :This OID gives the 3V3 voltage value of the Client Transceiver, read from the DDM (Digital Diagnostic Monitoring) (Voltage = AV/1000) (Un…
1.3.6.1.4.1.20044.58.3.2.10Scalarpm10010mpMesrclientSoaBiasCurrentread-onlycurrentClient Trscv SOA Bias :This OID gives the SOA bias value of the Client Transceiver, read from the DDM (Digital Diagnostic Monitoring) (Bias = AV/500) (Unit = m…
1.3.6.1.4.1.20044.58.3.2.16Tablepm10010mpMesrclientNetTxTempTablenot-accessiblecurrentList of pm10010mpMesrclientNetTxTemp Article
1.3.6.1.4.1.20044.58.3.2.16.1Rowpm10010mpMesrclientNetTxTempEntrynot-accessiblecurrentRow definition for the pm10010mpMesrclientNetTxTemp table
1.3.6.1.4.1.20044.58.3.2.16.1.1Columnpm10010mpMesrclientNetTxTempIndexread-onlycurrentIndex definition for the pm10010mpMesrclientNetTxTemp table
1.3.6.1.4.1.20044.58.3.2.16.1.2Columnpm10010mpMesrclientNetTxTempPortnread-onlycurrentClient Trscv Temperature :This OID gives the Laser temperature value of the Client Transceiver, read from the DDM (Digital Diagnostic Monitoring) (Temperature …
1.3.6.1.4.1.20044.58.3.2.32Tablepm10010mpMesrclientNetTxBiasTablenot-accessiblecurrentList of pm10010mpMesrclientNetTxBias Article
1.3.6.1.4.1.20044.58.3.2.32.1Rowpm10010mpMesrclientNetTxBiasEntrynot-accessiblecurrentRow definition for the pm10010mpMesrclientNetTxBias table
1.3.6.1.4.1.20044.58.3.2.32.1.1Columnpm10010mpMesrclientNetTxBiasIndexread-onlycurrentIndex definition for the pm10010mpMesrclientNetTxBias table
1.3.6.1.4.1.20044.58.3.2.32.1.2Columnpm10010mpMesrclientNetTxBiasPortnread-onlycurrentClient Trscv Laser Bias :This OID gives the Laser bias value of the Client Transceiver, read from the DDM (Digital Diagnostic Monitoring) (Bias = AV/500) (Unit…
1.3.6.1.4.1.20044.58.3.2.48Tablepm10010mpMesrclientNetTxPwrTablenot-accessiblecurrentList of pm10010mpMesrclientNetTxPwr Article
1.3.6.1.4.1.20044.58.3.2.48.1Rowpm10010mpMesrclientNetTxPwrEntrynot-accessiblecurrentRow definition for the pm10010mpMesrclientNetTxPwr table
1.3.6.1.4.1.20044.58.3.2.48.1.1Columnpm10010mpMesrclientNetTxPwrIndexread-onlycurrentIndex definition for the pm10010mpMesrclientNetTxPwr table
1.3.6.1.4.1.20044.58.3.2.48.1.2Columnpm10010mpMesrclientNetTxPwrPortnread-onlycurrentClient Trscv Tx Power :This OID gives the transmit power value of the Client Transceiver, read from the DDM (Digital Diagnostic Monitoring) (Power = 10*log(AV)…
1.3.6.1.4.1.20044.58.3.2.64Tablepm10010mpMesrclientNetRxPwrTablenot-accessiblecurrentList of pm10010mpMesrclientNetRxPwr Article
1.3.6.1.4.1.20044.58.3.2.64.1Rowpm10010mpMesrclientNetRxPwrEntrynot-accessiblecurrentRow definition for the pm10010mpMesrclientNetRxPwr table
1.3.6.1.4.1.20044.58.3.2.64.1.1Columnpm10010mpMesrclientNetRxPwrIndexread-onlycurrentIndex definition for the pm10010mpMesrclientNetRxPwr table
1.3.6.1.4.1.20044.58.3.2.64.1.2Columnpm10010mpMesrclientNetRxPwrPortnread-onlycurrentClient Trscv Rx Power :This OID gives the receive power value of the Client Transceiver, read in the DDM (Digital Diagnostic Monitoring) (Power = 10*log(AV)-40…
1.3.6.1.4.1.20044.58.3.3Nodepm10010mpMesrLine
1.3.6.1.4.1.20044.58.3.3.12Scalarpm10010mpMesrlineMsaTempread-onlycurrentLine Trscv Temperature :This OID gives the temperature value of the Line Transceiver, read from the DDM (Digital Diagnostic Monitoring) (Temperature = AV/256) …
1.3.6.1.4.1.20044.58.3.3.13Scalarpm10010mpMesrlineMsa3v3Voltageread-onlycurrentLine Trscv Voltage :This OID gives the 3V3 voltage value of the Line Transceiver, read from the DDM (Digital Diagnostic Monitoring) (Voltage = AV/1000) (Unit =…
1.3.6.1.4.1.20044.58.3.3.14Scalarpm10010mpMesrlineSoaBiasCurrentread-onlycurrentLine Trscv SOA Bias :This OID gives the SOA bias value of the Line Transceiver,read from the DDM (Digital Diagnostic Monitoring) (Bias = AV/500) (Unit = mA) <H…
1.3.6.1.4.1.20044.58.3.3.80Tablepm10010mpMesrlineNetTxLaserOutputPwrTablenot-accessiblecurrentList of pm10010mpMesrlineNetTxLaserOutputPwr Article
1.3.6.1.4.1.20044.58.3.3.80.1Rowpm10010mpMesrlineNetTxLaserOutputPwrEntrynot-accessiblecurrentRow definition for the pm10010mpMesrlineNetTxLaserOutputPwr table
1.3.6.1.4.1.20044.58.3.3.80.1.1Columnpm10010mpMesrlineNetTxLaserOutputPwrIndexread-onlycurrentIndex definition for the pm10010mpMesrlineNetTxLaserOutputPwr table
1.3.6.1.4.1.20044.58.3.3.80.1.2Columnpm10010mpMesrlineNetTxLaserOutputPwrPortnread-onlycurrentCurrent Line Trscv Tx Power :This OID gives the Tx Laser transmit power value of the Line Transceiver, read in the DDM (Digital Diagnostic Monitoring) (Power =…
1.3.6.1.4.1.20044.58.3.3.96Tablepm10010mpMesrlineNetTxLaserTempTablenot-accessiblecurrentList of pm10010mpMesrlineNetTxLaserTemp Article
1.3.6.1.4.1.20044.58.3.3.96.1Rowpm10010mpMesrlineNetTxLaserTempEntrynot-accessiblecurrentRow definition for the pm10010mpMesrlineNetTxLaserTemp table
1.3.6.1.4.1.20044.58.3.3.96.1.1Columnpm10010mpMesrlineNetTxLaserTempIndexread-onlycurrentIndex definition for the pm10010mpMesrlineNetTxLaserTemp table
1.3.6.1.4.1.20044.58.3.3.96.1.2Columnpm10010mpMesrlineNetTxLaserTempPortnread-onlycurrentCurrent Line Trscv Tx Laser Temperature :This OID gives the Tx Laser Temperature value of the Line Transceiver, read from the DDM (Digital Diagnostic Monitorin…
1.3.6.1.4.1.20044.58.3.3.112Tablepm10010mpMesrlineNetTxBiasCurrentTablenot-accessiblecurrentList of pm10010mpMesrlineNetTxBiasCurrent Article
1.3.6.1.4.1.20044.58.3.3.112.1Rowpm10010mpMesrlineNetTxBiasCurrentEntrynot-accessiblecurrentRow definition for the pm10010mpMesrlineNetTxBiasCurrent table
1.3.6.1.4.1.20044.58.3.3.112.1.1Columnpm10010mpMesrlineNetTxBiasCurrentIndexread-onlycurrentIndex definition for the pm10010mpMesrlineNetTxBiasCurrent table
1.3.6.1.4.1.20044.58.3.3.112.1.2Columnpm10010mpMesrlineNetTxBiasCurrentPortnread-onlycurrentCurrent Line Trscv Tx Laser Bias :This OID gives the Tx Laser Bias value of the Line Transceiver, read from the DDM (Digital Diagnostic Monitoring) (Bias = AV/…
1.3.6.1.4.1.20044.58.3.3.128Tablepm10010mpMesrlineNetRxInputPwrTablenot-accessiblecurrentList of pm10010mpMesrlineNetRxInputPwr Article
1.3.6.1.4.1.20044.58.3.3.128.1Rowpm10010mpMesrlineNetRxInputPwrEntrynot-accessiblecurrentRow definition for the pm10010mpMesrlineNetRxInputPwr table
1.3.6.1.4.1.20044.58.3.3.128.1.1Columnpm10010mpMesrlineNetRxInputPwrIndexread-onlycurrentIndex definition for the pm10010mpMesrlineNetRxInputPwr table
1.3.6.1.4.1.20044.58.3.3.128.1.2Columnpm10010mpMesrlineNetRxInputPwrPortnread-onlycurrentCurrent Line Trscv Rx Power :This OID gives the Receive power value of the Line Transceiver, read in the DDM (Digital Diagnostic Monitoring) (Power = AV/100) (…
1.3.6.1.4.1.20044.58.3.3.144Tablepm10010mpMesrlineResidualChromaticDispTablenot-accessiblecurrentList of pm10010mpMesrlineResidualChromaticDisp Article
1.3.6.1.4.1.20044.58.3.3.144.1Rowpm10010mpMesrlineResidualChromaticDispEntrynot-accessiblecurrentRow definition for the pm10010mpMesrlineResidualChromaticDisp table
1.3.6.1.4.1.20044.58.3.3.144.1.1Columnpm10010mpMesrlineResidualChromaticDispIndexread-onlycurrentIndex definition for the pm10010mpMesrlineResidualChromaticDisp table
1.3.6.1.4.1.20044.58.3.3.144.1.2Columnpm10010mpMesrlineResidualChromaticDispPortnread-onlycurrentCurrent Residual Chromatic Dispersion :This OID gives the current Residual Chromatic Dispersion on the Line interface (Unit = ps/nm)<Help> This measure gives t…
1.3.6.1.4.1.20044.58.3.3.148Tablepm10010mpMesrlineDiffGroupDelayTablenot-accessiblecurrentList of pm10010mpMesrlineDiffGroupDelay Article
1.3.6.1.4.1.20044.58.3.3.148.1Rowpm10010mpMesrlineDiffGroupDelayEntrynot-accessiblecurrentRow definition for the pm10010mpMesrlineDiffGroupDelay table
1.3.6.1.4.1.20044.58.3.3.148.1.1Columnpm10010mpMesrlineDiffGroupDelayIndexread-onlycurrentIndex definition for the pm10010mpMesrlineDiffGroupDelay table
1.3.6.1.4.1.20044.58.3.3.148.1.2Columnpm10010mpMesrlineDiffGroupDelayPortnread-onlycurrentCurrent Differential Group Delay :This OID gives the current Differential Group Delay on the Line interface (Unit = ps)<Help> This measure gives the current Di…
1.3.6.1.4.1.20044.58.3.3.152Tablepm10010mpMesrlineQFactorTablenot-accessiblecurrentList of pm10010mpMesrlineQFactor Article
1.3.6.1.4.1.20044.58.3.3.152.1Rowpm10010mpMesrlineQFactorEntrynot-accessiblecurrentRow definition for the pm10010mpMesrlineQFactor table
1.3.6.1.4.1.20044.58.3.3.152.1.1Columnpm10010mpMesrlineQFactorIndexread-onlycurrentIndex definition for the pm10010mpMesrlineQFactor table
1.3.6.1.4.1.20044.58.3.3.152.1.2Columnpm10010mpMesrlineQFactorPortnread-onlycurrentCurrent Q Factor :This OID gives the current Q Factor on the Line interface (Unit = dB) <Help> This measure gives the current Q Factor on the Line interface.
1.3.6.1.4.1.20044.58.3.3.156Tablepm10010mpMesrlineCarrierFreqOffsetTablenot-accessiblecurrentList of pm10010mpMesrlineCarrierFreqOffset Article
1.3.6.1.4.1.20044.58.3.3.156.1Rowpm10010mpMesrlineCarrierFreqOffsetEntrynot-accessiblecurrentRow definition for the pm10010mpMesrlineCarrierFreqOffset table
1.3.6.1.4.1.20044.58.3.3.156.1.1Columnpm10010mpMesrlineCarrierFreqOffsetIndexread-onlycurrentIndex definition for the pm10010mpMesrlineCarrierFreqOffset table
1.3.6.1.4.1.20044.58.3.3.156.1.2Columnpm10010mpMesrlineCarrierFreqOffsetPortnread-onlycurrentCurrent Carrier Frequency Offset :This OID gives the current Carrier Frequency Offset on the Line interface (Unit = Mhz)<Help> This measure gives the current C…
1.3.6.1.4.1.20044.58.3.3.160Tablepm10010mpMesrlineOsnrTablenot-accessiblecurrentList of pm10010mpMesrlineOsnr Article
1.3.6.1.4.1.20044.58.3.3.160.1Rowpm10010mpMesrlineOsnrEntrynot-accessiblecurrentRow definition for the pm10010mpMesrlineOsnr table
1.3.6.1.4.1.20044.58.3.3.160.1.1Columnpm10010mpMesrlineOsnrIndexread-onlycurrentIndex definition for the pm10010mpMesrlineOsnr table
1.3.6.1.4.1.20044.58.3.3.160.1.2Columnpm10010mpMesrlineOsnrPortnread-onlycurrentCurrent OSNR :This OID gives the current OSNR on the Line interface (OSNR = AV/10) (Unit = dB)<Help> This measure gives the current OSNR on the Line interface.
1.3.6.1.4.1.20044.58.4Nodepm10010mpcounters
1.3.6.1.4.1.20044.58.4.1Nodepm10010mpCntOther
1.3.6.1.4.1.20044.58.4.2Nodepm10010mpCntClient
1.3.6.1.4.1.20044.58.4.2.16Tablepm10010mpCntclientInputErrorCounterLaneOneTablenot-accessiblecurrentList of pm10010mpCntclientInputErrorCounterLaneOne Article
1.3.6.1.4.1.20044.58.4.2.16.1Rowpm10010mpCntclientInputErrorCounterLaneOneEntrynot-accessiblecurrentRow definition for the pm10010mpCntclientInputErrorCounterLaneOne table
1.3.6.1.4.1.20044.58.4.2.16.1.1Columnpm10010mpCntclientInputErrorCounterLaneOneIndexread-onlycurrentIndex definition for the pm10010mpCntclientInputErrorCounterLaneOne table
1.3.6.1.4.1.20044.58.4.2.16.1.2Columnpm10010mpCntclientInputErrorCounterLaneOneValuePortnread-onlycurrentClient_Input_Error_Counter_Lane1 :This counter is incremented each time a coding violation is detected on the host lane of the client transceiver <Help> This c…
1.3.6.1.4.1.20044.58.4.2.16.1.3Columnpm10010mpCntclientInputErrorCounterLaneOneErrorPortnread-onlycurrentClient Input Counter Error :This OID when set indicates the rate adaptation removal counter value is invalid on Port
1.3.6.1.4.1.20044.58.4.2.16.1.4Columnpm10010mpCntclientInputErrorCounterLaneOneOverloadPortnread-onlycurrentClient Input Counter Overload :This OID when set indicates a rate adaptation removal counter overload on Port
1.3.6.1.4.1.20044.58.4.2.32Tablepm10010mpCntclientInputErrorCounterLaneTwoTablenot-accessiblecurrentList of pm10010mpCntclientInputErrorCounterLaneTwo Article
1.3.6.1.4.1.20044.58.4.2.32.1Rowpm10010mpCntclientInputErrorCounterLaneTwoEntrynot-accessiblecurrentRow definition for the pm10010mpCntclientInputErrorCounterLaneTwo table
1.3.6.1.4.1.20044.58.4.2.32.1.1Columnpm10010mpCntclientInputErrorCounterLaneTwoIndexread-onlycurrentIndex definition for the pm10010mpCntclientInputErrorCounterLaneTwo table
1.3.6.1.4.1.20044.58.4.2.32.1.2Columnpm10010mpCntclientInputErrorCounterLaneTwoValuePortnread-onlycurrentClient_Input_Error_Counter_Lane2 :This counter is incremented each time a coding violation is detected on the host lane of the client transceiver <Help> This c…
1.3.6.1.4.1.20044.58.4.2.32.1.3Columnpm10010mpCntclientInputErrorCounterLaneTwoErrorPortnread-onlycurrentClient Input Counter Error :This OID when set indicates the client error counter value is invalid on Port
1.3.6.1.4.1.20044.58.4.2.32.1.4Columnpm10010mpCntclientInputErrorCounterLaneTwoOverloadPortnread-onlycurrentClient Input Counter Overload :This OID when set indicates a client input error counter overload on Port
1.3.6.1.4.1.20044.58.4.2.80Tablepm10010mpCntclientInputErrorCounterTablenot-accessiblecurrentList of pm10010mpCntclientInputErrorCounter Article
1.3.6.1.4.1.20044.58.4.2.80.1Rowpm10010mpCntclientInputErrorCounterEntrynot-accessiblecurrentRow definition for the pm10010mpCntclientInputErrorCounter table
1.3.6.1.4.1.20044.58.4.2.80.1.1Columnpm10010mpCntclientInputErrorCounterIndexread-onlycurrentIndex definition for the pm10010mpCntclientInputErrorCounter table
1.3.6.1.4.1.20044.58.4.2.80.1.2Columnpm10010mpCntclientInputErrorCounterValuePortnread-onlycurrentClient Input Errors :This counter is increased each time a 10b/8b running disparity error is detected on the Client input stream <Help> This counter gives the …
1.3.6.1.4.1.20044.58.4.2.80.1.3Columnpm10010mpCntclientInputErrorCounterErrorPortnread-onlycurrentClient Counter Error :This OID when set indicates the client error counter value is invalid on Port
1.3.6.1.4.1.20044.58.4.2.80.1.4Columnpm10010mpCntclientInputErrorCounterOverloadPortnread-onlycurrentClient Counter Overload :This OID when set indicates a client input error counter overload on Port
1.3.6.1.4.1.20044.58.4.2.96Tablepm10010mpCntclientCbipCounterTablenot-accessiblecurrentList of pm10010mpCntclientCbipCounter Article
1.3.6.1.4.1.20044.58.4.2.96.1Rowpm10010mpCntclientCbipCounterEntrynot-accessiblecurrentRow definition for the pm10010mpCntclientCbipCounter table
1.3.6.1.4.1.20044.58.4.2.96.1.1Columnpm10010mpCntclientCbipCounterIndexread-onlycurrentIndex definition for the pm10010mpCntclientCbipCounter table
1.3.6.1.4.1.20044.58.4.2.96.1.2Columnpm10010mpCntclientCbipCounterValuePortnread-onlycurrentClient Output Errors :This counter is incremented each time a CBIP parity error is detected on the Client output stream <Help> This counter gives the number of…
1.3.6.1.4.1.20044.58.4.2.96.1.3Columnpm10010mpCntclientCbipCounterErrorPortnread-onlycurrentClient Counter Error :This OID when set indicates the CBIP error counter value is invalid on Port
1.3.6.1.4.1.20044.58.4.2.96.1.4Columnpm10010mpCntclientCbipCounterOverloadPortnread-onlycurrentClient CBIP Counter Overload :This OID when set indicates a CBIP error counter overload on Port
1.3.6.1.4.1.20044.58.4.3Nodepm10010mpCntLine
1.3.6.1.4.1.20044.58.4.3.192Tablepm10010mpCntlocalLineSmBip8ErrorCounterTablenot-accessiblecurrentList of pm10010mpCntlocalLineSmBip8ErrorCounter Article
1.3.6.1.4.1.20044.58.4.3.192.1Rowpm10010mpCntlocalLineSmBip8ErrorCounterEntrynot-accessiblecurrentRow definition for the pm10010mpCntlocalLineSmBip8ErrorCounter table
1.3.6.1.4.1.20044.58.4.3.192.1.1Columnpm10010mpCntlocalLineSmBip8ErrorCounterIndexread-onlycurrentIndex definition for the pm10010mpCntlocalLineSmBip8ErrorCounter table
1.3.6.1.4.1.20044.58.4.3.192.1.2Columnpm10010mpCntlocalLineSmBip8ErrorCounterValuePortnread-onlycurrentLine Input SM-BIP8 Errors :This OID gives the current Bit Error Rate (residual SM-BIP8 error) after FEC <Help> This counter gives the current Bit Error Rate (r…
1.3.6.1.4.1.20044.58.4.3.192.1.3Columnpm10010mpCntlocalLineSmBip8ErrorCounterErrorPortnread-onlycurrentLine Counter Error :This OID when set indicates the B1 error counter value is invalid on Port
1.3.6.1.4.1.20044.58.4.3.192.1.4Columnpm10010mpCntlocalLineSmBip8ErrorCounterOverloadPortnread-onlycurrentLine Counter Overload :This OID when set indicates a B1 error counter overload on Port
1.3.6.1.4.1.20044.58.4.3.193Tablepm10010mpCntlocalLineFecCorrectedErrorsCounterTablenot-accessiblecurrentList of pm10010mpCntlocalLineFecCorrectedErrorsCounter Article
1.3.6.1.4.1.20044.58.4.3.193.1Rowpm10010mpCntlocalLineFecCorrectedErrorsCounterEntrynot-accessiblecurrentRow definition for the pm10010mpCntlocalLineFecCorrectedErrorsCounter table
1.3.6.1.4.1.20044.58.4.3.193.1.1Columnpm10010mpCntlocalLineFecCorrectedErrorsCounterIndexread-onlycurrentIndex definition for the pm10010mpCntlocalLineFecCorrectedErrorsCounter table
1.3.6.1.4.1.20044.58.4.3.193.1.2Columnpm10010mpCntlocalLineFecCorrectedErrorsCounterValuePortnread-onlycurrentLine Input HD FEC Corrected Errors :This OID gives the current Bit Error Rate before the Hard Decision FEC <Help> This counter gives the current Bit Error Rate…
1.3.6.1.4.1.20044.58.4.3.193.1.3Columnpm10010mpCntlocalLineFecCorrectedErrorsCounterErrorPortnread-onlycurrentFEC Counter Error :This bit when set indicates the FEC corrected errors counter value is invalid on Line
1.3.6.1.4.1.20044.58.4.3.193.1.4Columnpm10010mpCntlocalLineFecCorrectedErrorsCounterOverloadPortnread-onlycurrentFEC Counter Overload :This bit when set indicates a FEC corrected errors counter overload on Line
1.3.6.1.4.1.20044.58.4.3.194Tablepm10010mpCntremoteLineSmBip8ErrorCounterTablenot-accessiblecurrentList of pm10010mpCntremoteLineSmBip8ErrorCounter Article
1.3.6.1.4.1.20044.58.4.3.194.1Rowpm10010mpCntremoteLineSmBip8ErrorCounterEntrynot-accessiblecurrentRow definition for the pm10010mpCntremoteLineSmBip8ErrorCounter table
1.3.6.1.4.1.20044.58.4.3.194.1.1Columnpm10010mpCntremoteLineSmBip8ErrorCounterIndexread-onlycurrentIndex definition for the pm10010mpCntremoteLineSmBip8ErrorCounter table
1.3.6.1.4.1.20044.58.4.3.194.1.2Columnpm10010mpCntremoteLineSmBip8ErrorCounterValuePortnread-onlycurrentRemote SM BIP8 :This OID gives the current Bit Error Rate (residual SM-BIP8 error) after FEC on the remote side <Help> This counter gives the current Bit Error…
1.3.6.1.4.1.20044.58.4.3.194.1.3Columnpm10010mpCntremoteLineSmBip8ErrorCounterErrorPortnread-onlycurrentRemote Counter Error :
1.3.6.1.4.1.20044.58.4.3.194.1.4Columnpm10010mpCntremoteLineSmBip8ErrorCounterOverloadPortnread-onlycurrentRemote Counter Overload :
1.3.6.1.4.1.20044.58.4.3.195Tablepm10010mpCntlineDfrmTimCntTablenot-accessiblecurrentList of pm10010mpCntlineDfrmTimCnt Article
1.3.6.1.4.1.20044.58.4.3.195.1Rowpm10010mpCntlineDfrmTimCntEntrynot-accessiblecurrentRow definition for the pm10010mpCntlineDfrmTimCnt table
1.3.6.1.4.1.20044.58.4.3.195.1.1Columnpm10010mpCntlineDfrmTimCntIndexread-onlycurrentIndex definition for the pm10010mpCntlineDfrmTimCnt table
1.3.6.1.4.1.20044.58.4.3.195.1.2Columnpm10010mpCntlineDfrmTimCntValuePortnread-onlycurrentLine Timer Counter :
1.3.6.1.4.1.20044.58.4.3.195.1.3Columnpm10010mpCntlineDfrmTimCntErrorPortnread-onlycurrentLine Counter Error :This OID when set indicates the deframer timer counter value is invalid on Port
1.3.6.1.4.1.20044.58.4.3.195.1.4Columnpm10010mpCntlineDfrmTimCntOverloadPortnread-onlycurrentLine Counter Overload :This OID when set indicates a deframer timer counter overload on Port
1.3.6.1.4.1.20044.58.4.3.196Tablepm10010mpCntlocalLineTrscvFecCorrectedErrorCounterTablenot-accessiblecurrentList of pm10010mpCntlocalLineTrscvFecCorrectedErrorCounter Article
1.3.6.1.4.1.20044.58.4.3.196.1Rowpm10010mpCntlocalLineTrscvFecCorrectedErrorCounterEntrynot-accessiblecurrentRow definition for the pm10010mpCntlocalLineTrscvFecCorrectedErrorCounter table
1.3.6.1.4.1.20044.58.4.3.196.1.1Columnpm10010mpCntlocalLineTrscvFecCorrectedErrorCounterIndexread-onlycurrentIndex definition for the pm10010mpCntlocalLineTrscvFecCorrectedErrorCounter table
1.3.6.1.4.1.20044.58.4.3.196.1.2Columnpm10010mpCntlocalLineTrscvFecCorrectedErrorCounterValuePortnread-onlycurrentLine Input SD FEC Corrected Errors :This OID gives the current Bit Error Rate before the Soft Decision FEC <Help> This counter gives the current Bit Error Rate…
1.3.6.1.4.1.20044.58.4.3.196.1.3Columnpm10010mpCntlocalLineTrscvFecCorrectedErrorCounterErrorPortnread-onlycurrentLine Counter Error :This OID when set indicates the deframer timer counter value is invalid on Port
1.3.6.1.4.1.20044.58.4.3.196.1.4Columnpm10010mpCntlocalLineTrscvFecCorrectedErrorCounterOverloadPortnread-onlycurrentLine Counter Overload :This OID when set indicates a deframer timer counter overload on Port
1.3.6.1.4.1.20044.58.4.3.197Tablepm10010mpCntlocalLineTrscvFecUncorrectedErrorCounterTablenot-accessiblecurrentList of pm10010mpCntlocalLineTrscvFecUncorrectedErrorCounter Article
1.3.6.1.4.1.20044.58.4.3.197.1Rowpm10010mpCntlocalLineTrscvFecUncorrectedErrorCounterEntrynot-accessiblecurrentRow definition for the pm10010mpCntlocalLineTrscvFecUncorrectedErrorCounter table
1.3.6.1.4.1.20044.58.4.3.197.1.1Columnpm10010mpCntlocalLineTrscvFecUncorrectedErrorCounterIndexread-onlycurrentIndex definition for the pm10010mpCntlocalLineTrscvFecUncorrectedErrorCounter table
1.3.6.1.4.1.20044.58.4.3.197.1.2Columnpm10010mpCntlocalLineTrscvFecUncorrectedErrorCounterValuePortnread-onlycurrentSD Uncorrected :This OID gives the current Bit Error Rate after the Soft Decision FEC (residual) <Help> This counter gives the current Bit Error Rate after the…
1.3.6.1.4.1.20044.58.4.3.197.1.3Columnpm10010mpCntlocalLineTrscvFecUncorrectedErrorCounterErrorPortnread-onlycurrentLine Counter Error :This OID when set indicates the deframer timer counter value is invalid on Port
1.3.6.1.4.1.20044.58.4.3.197.1.4Columnpm10010mpCntlocalLineTrscvFecUncorrectedErrorCounterOverloadPortnread-onlycurrentLine Counter Overload :This OID when set indicates a deframer timer counter overload on Port
1.3.6.1.4.1.20044.58.6Nodepm10010mpcontrolsWrite
1.3.6.1.4.1.20044.58.6.1Nodepm10010mpCtrlOther
1.3.6.1.4.1.20044.58.6.1.1Nodepm10010mpCtrlconfMgnt1
1.3.6.1.4.1.20044.58.6.1.1.1Scalarpm10010mpCtrlConf1Load1read-writecurrentLoad Configuration Tables Set Nb 1 :When set this OID enables loading from flash configuration1 into the PM.
1.3.6.1.4.1.20044.58.6.1.1.2Scalarpm10010mpCtrlConf2Load1read-writecurrentLoad Configuration Tables Set Nb 2 :When set this OID enables loading from flash configuration2 into the PM.
1.3.6.1.4.1.20044.58.6.1.1.10Scalarpm10010mpCtrlConf2Flash1read-writecurrentWrite Configuration Tables :This OID saves the current configuration of the PM as configuration2 in the flash. <Help> This control saves the customer configura…
1.3.6.1.4.1.20044.58.6.1.1.14Scalarpm10010mpCtrlConf2Clear1read-writecurrentClear Configuration Tables :This OID clears the configuration tables from configuration2 in the flash. <Help> This control restores the default configuration o…
1.3.6.1.4.1.20044.58.6.1.4Nodepm10010mpCtrlsynth4
1.3.6.1.4.1.20044.58.6.1.4.1Scalarpm10010mpCtrlCorrelatOnread-writecurrentEnable Alarm Correlation :This OID enables the alarm correlation in the PM.
1.3.6.1.4.1.20044.58.6.1.4.2Scalarpm10010mpCtrlCorrelatOffread-writecurrentDisable Alarm Correlation :This OID disables the alarm correlation in the PM.
1.3.6.1.4.1.20044.58.6.1.5Nodepm10010mpCtrlswMgnt
1.3.6.1.4.1.20044.58.6.1.5.2Scalarpm10010mpCtrlColdResetread-writecurrentPM Cold Reset :This OID, when set, causes a cold reset of the PM. This reset is traffic affecting, and the configuration of PM is reloaded on start-up. <Help> …
1.3.6.1.4.1.20044.58.6.1.5.3Scalarpm10010mpCtrlWarmResetread-writecurrentPM Warm Reset :This OID, when set, causes a warm reset of the PM. This reset is not traffic affecting, and the configuration of PM remains unchanged. <Help> Th…
1.3.6.1.4.1.20044.58.6.1.5.5Scalarpm10010mpCtrlLoadSwBank1read-writecurrentSet Software Nb 1 As Active :This OID, when set, loads the SW from bank1 into the PM. It must be followed by a reset. <Help> This controls selects the first SW…
1.3.6.1.4.1.20044.58.6.1.5.6Scalarpm10010mpCtrlLoadSwBank2read-writecurrentSet Software Nb 2 As Active :This OID, when set, loads the SW from bank2 into the PM. It must be followed by a reset. <Help> This controls selects the second S…
1.3.6.1.4.1.20044.58.6.1.6Nodepm10010mpCtrlgwMgnt
1.3.6.1.4.1.20044.58.6.1.6.1Scalarpm10010mpCtrlCurrentGwResetread-writecurrentActive Gateware Reset :This OID, when set, resets the active gateware. It is traffic affecting.
1.3.6.1.4.1.20044.58.6.1.6.5Scalarpm10010mpCtrlLoadGwBank1read-writecurrentSet Gateware Nb 1 As Active :This OID, when set, loads the GW from bank1 (Flash) into the PM. It is followed by an automatic gateware cold reset. <Help> This c…
1.3.6.1.4.1.20044.58.6.1.6.6Scalarpm10010mpCtrlLoadGwBank2read-writecurrentSet Gateware Nb 2 As Active :This OID, when set, loads the GW from bank2 (Flash) into the PM. It is followed by an automatic gateware cold reset.
1.3.6.1.4.1.20044.58.6.1.6.7Scalarpm10010mpCtrlLoadGwBank3read-writecurrentSet Gateware Nb 3 As Active :This OID, when set, loads the GW from bank3 (Flash) into the PM. It is followed by an automatic gateware cold reset. <Help> This c…
1.3.6.1.4.1.20044.58.6.1.6.8Scalarpm10010mpCtrlLoadGwBank4read-writecurrentSet Gateware Nb 4 As Active :This OID, when set, loads the GW from bank4 (Flash) into the PM. It is followed by an automatic gateware cold reset.
1.3.6.1.4.1.20044.58.6.1.192Nodepm10010mpCtrlledTest
1.3.6.1.4.1.20044.58.6.1.192.1Scalarpm10010mpCtrlGreenLedread-writecurrentGreen Leds Test :This OID switches on all the green Leds as a test feature. <Help> This control initiates a test leds turning all the LEDs to green
1.3.6.1.4.1.20044.58.6.1.192.2Scalarpm10010mpCtrlRedLedread-writecurrentRed Leds Test :This OID switches on all the red Leds as a test feature. <Help> This control initiates a test leds turning all the LEDs to red
1.3.6.1.4.1.20044.58.6.1.192.3Scalarpm10010mpCtrlLedOffread-writecurrentLeds Off :This OID switches off all the Leds as a test feature. <Help> This control initiates a test leds turning all the LEDs to OFF
1.3.6.1.4.1.20044.58.6.1.201Nodepm10010mpCtrlinitSwitchMarvell
1.3.6.1.4.1.20044.58.6.1.201.1Scalarpm10010mpCtrlInitSwitchMarvellread-writecurrentSwitch Initialization :This OID operates an initialization of the switch managed through the module <Help> This control activates an initialization of the swit…
1.3.6.1.4.1.20044.58.6.1.259Nodepm10010mpCtrlresetCount
1.3.6.1.4.1.20044.58.6.1.259.1Scalarpm10010mpCtrlResetcountread-writecurrentModule Count Global Reset :This OID resets all the errors counters on the module <Help > This control initiates a reset of the errors counters on the module
1.3.6.1.4.1.20044.58.6.1.260Nodepm10010mpCtrlresetRmon
1.3.6.1.4.1.20044.58.6.1.260.1Scalarpm10010mpCtrlResetrmonread-writecurrentModule Rmon Global Reset :This OID resets all the Rmon counters on the module <Help > This control initiates a reset of the Rmon counters on the module
1.3.6.1.4.1.20044.58.6.1.261Nodepm10010mpCtrlresetMeasurements
1.3.6.1.4.1.20044.58.6.1.261.1Scalarpm10010mpCtrlResetmeasurementsread-writecurrentManagement Meas Global Reset :This OID resets some measurements on the management <Help > This control initiates a reset of some measurements on the management
1.3.6.1.4.1.20044.58.6.2Nodepm10010mpCtrlClient
1.3.6.1.4.1.20044.58.6.2.16Tablepm10010mpCtrlaccessLoopTablenot-accessiblecurrentList of pm10010mpCtrlaccessLoop Article
1.3.6.1.4.1.20044.58.6.2.16.1Rowpm10010mpCtrlaccessLoopEntrynot-accessiblecurrentRow definition for the pm10010mpCtrlaccessLoop table
1.3.6.1.4.1.20044.58.6.2.16.1.1Columnpm10010mpCtrlaccessLoopIndexread-onlycurrentIndex definition for the pm10010mpCtrlaccessLoop table
1.3.6.1.4.1.20044.58.6.2.16.1.2Columnpm10010mpCtrlaccessLoopPortnread-writecurrentClient Facility Loopback :This OID, when set at '1' puts the client port in loopback, looping the received 10 Gb/s signal on the transmit 10 Gb/s output. <Help…
1.3.6.1.4.1.20044.58.6.2.17Tablepm10010mpCtrlclientLoopToLineTablenot-accessiblecurrentList of pm10010mpCtrlclientLoopToLine Article
1.3.6.1.4.1.20044.58.6.2.17.1Rowpm10010mpCtrlclientLoopToLineEntrynot-accessiblecurrentRow definition for the pm10010mpCtrlclientLoopToLine table
1.3.6.1.4.1.20044.58.6.2.17.1.1Columnpm10010mpCtrlclientLoopToLineIndexread-onlycurrentIndex definition for the pm10010mpCtrlclientLoopToLine table
1.3.6.1.4.1.20044.58.6.2.17.1.2Columnpm10010mpCtrlclientLoopToLinePortnread-writecurrentClient Terminal Loopback :This OID, when set, puts the client port in loop back, looping the 10 Gb/s output signal on the 10 Gb/s input.<Help> This control ena…
1.3.6.1.4.1.20044.58.6.2.21Tablepm10010mpCtrlcsfUpInsTablenot-accessiblecurrentList of pm10010mpCtrlcsfUpIns Article
1.3.6.1.4.1.20044.58.6.2.21.1Rowpm10010mpCtrlcsfUpInsEntrynot-accessiblecurrentRow definition for the pm10010mpCtrlcsfUpIns table
1.3.6.1.4.1.20044.58.6.2.21.1.1Columnpm10010mpCtrlcsfUpInsIndexread-onlycurrentIndex definition for the pm10010mpCtrlcsfUpIns table
1.3.6.1.4.1.20044.58.6.2.21.1.2Columnpm10010mpCtrlcsfUpInsPortnread-writecurrentClient Signal Fail Insertion :This OID, when set, inserts a client signal fail in the upstream client Port. <Help> This control inserts a Client Signal Fail fo…
1.3.6.1.4.1.20044.58.6.2.22Tablepm10010mpCtrlcaisDwInsTablenot-accessiblecurrentList of pm10010mpCtrlcaisDwIns Article
1.3.6.1.4.1.20044.58.6.2.22.1Rowpm10010mpCtrlcaisDwInsEntrynot-accessiblecurrentRow definition for the pm10010mpCtrlcaisDwIns table
1.3.6.1.4.1.20044.58.6.2.22.1.1Columnpm10010mpCtrlcaisDwInsIndexread-onlycurrentIndex definition for the pm10010mpCtrlcaisDwIns table
1.3.6.1.4.1.20044.58.6.2.22.1.2Columnpm10010mpCtrlcaisDwInsPortnread-writecurrentClient AIS Insertion :This OID, when set, inserts a client AIS on the downstream client Port. <Help> This control inserts a Client AIS for the client port
1.3.6.1.4.1.20044.58.6.3Nodepm10010mpCtrlLine
1.3.6.1.4.1.20044.58.6.3.64Tablepm10010mpCtrlcommAccessLoopTablenot-accessiblecurrentList of pm10010mpCtrlcommAccessLoop Article
1.3.6.1.4.1.20044.58.6.3.64.1Rowpm10010mpCtrlcommAccessLoopEntrynot-accessiblecurrentRow definition for the pm10010mpCtrlcommAccessLoop table
1.3.6.1.4.1.20044.58.6.3.64.1.1Columnpm10010mpCtrlcommAccessLoopIndexread-onlycurrentIndex definition for the pm10010mpCtrlcommAccessLoop table
1.3.6.1.4.1.20044.58.6.3.64.1.2Columnpm10010mpCtrlcommAccessLoopPortnread-writecurrentLine Terminal Loopback :This OID, when set, puts the module in common access loop back, looping the 100 Gb/s output signal on the 100 Gb/s input.<Help> This co…
1.3.6.1.4.1.20044.58.6.3.66Tablepm10010mpCtrllineLoopTablenot-accessiblecurrentList of pm10010mpCtrllineLoop Article
1.3.6.1.4.1.20044.58.6.3.66.1Rowpm10010mpCtrllineLoopEntrynot-accessiblecurrentRow definition for the pm10010mpCtrllineLoop table
1.3.6.1.4.1.20044.58.6.3.66.1.1Columnpm10010mpCtrllineLoopIndexread-onlycurrentIndex definition for the pm10010mpCtrllineLoop table
1.3.6.1.4.1.20044.58.6.3.66.1.2Columnpm10010mpCtrllineLoopPortnread-writecurrentLine Facility Loopback :This OID, when set at '1' puts the module in line loopback mode, looping the received 100 Gb/s signal on the transmit 100 Gb/s output. …
1.3.6.1.4.1.20044.58.6.3.69Tablepm10010mpCtrlfecDisableTablenot-accessiblecurrentList of pm10010mpCtrlfecDisable Article
1.3.6.1.4.1.20044.58.6.3.69.1Rowpm10010mpCtrlfecDisableEntrynot-accessiblecurrentRow definition for the pm10010mpCtrlfecDisable table
1.3.6.1.4.1.20044.58.6.3.69.1.1Columnpm10010mpCtrlfecDisableIndexread-onlycurrentIndex definition for the pm10010mpCtrlfecDisable table
1.3.6.1.4.1.20044.58.6.3.69.1.2Columnpm10010mpCtrlfecDisablePortnread-writecurrentForward Error Correction Inhibition :This OID, when set, inhibits the Forward Error Correction feature on the line input <Help> This control enables/disables t…
1.3.6.1.4.1.20044.58.6.3.209Tablepm10010mpCtrlmsaLineLoopTablenot-accessiblecurrentList of pm10010mpCtrlmsaLineLoop Article
1.3.6.1.4.1.20044.58.6.3.209.1Rowpm10010mpCtrlmsaLineLoopEntrynot-accessiblecurrentRow definition for the pm10010mpCtrlmsaLineLoop table
1.3.6.1.4.1.20044.58.6.3.209.1.1Columnpm10010mpCtrlmsaLineLoopIndexread-onlycurrentIndex definition for the pm10010mpCtrlmsaLineLoop table
1.3.6.1.4.1.20044.58.6.3.209.1.2Columnpm10010mpCtrlmsaLineLoopPortnread-writecurrentMSA Line Loop :This OID operates a line loopback on the MSA Line <Help> This control defines the line loop back of the line transceiver
1.3.6.1.4.1.20044.58.6.3.210Tablepm10010mpCtrlmsaTxResetTablenot-accessiblecurrentList of pm10010mpCtrlmsaTxReset Article
1.3.6.1.4.1.20044.58.6.3.210.1Rowpm10010mpCtrlmsaTxResetEntrynot-accessiblecurrentRow definition for the pm10010mpCtrlmsaTxReset table
1.3.6.1.4.1.20044.58.6.3.210.1.1Columnpm10010mpCtrlmsaTxResetIndexread-onlycurrentIndex definition for the pm10010mpCtrlmsaTxReset table
1.3.6.1.4.1.20044.58.6.3.210.1.2Columnpm10010mpCtrlmsaTxResetPortnread-writecurrentLine MSA TX Reset :This OID resets the TX portion of the MSA line module <Help > This control initiates a reset of the transmitting side
1.3.6.1.4.1.20044.58.6.3.211Tablepm10010mpCtrlmsaRxResetTablenot-accessiblecurrentList of pm10010mpCtrlmsaRxReset Article
1.3.6.1.4.1.20044.58.6.3.211.1Rowpm10010mpCtrlmsaRxResetEntrynot-accessiblecurrentRow definition for the pm10010mpCtrlmsaRxReset table
1.3.6.1.4.1.20044.58.6.3.211.1.1Columnpm10010mpCtrlmsaRxResetIndexread-onlycurrentIndex definition for the pm10010mpCtrlmsaRxReset table
1.3.6.1.4.1.20044.58.6.3.211.1.2Columnpm10010mpCtrlmsaRxResetPortnread-writecurrentLine MSA RX Reset :This OID resets the RX portion of the MSA line module <Help > This control initiates a reset of the receiving side
1.3.6.1.4.1.20044.58.6.3.212Tablepm10010mpCtrlmsaShutdownTablenot-accessiblecurrentList of pm10010mpCtrlmsaShutdown Article
1.3.6.1.4.1.20044.58.6.3.212.1Rowpm10010mpCtrlmsaShutdownEntrynot-accessiblecurrentRow definition for the pm10010mpCtrlmsaShutdown table
1.3.6.1.4.1.20044.58.6.3.212.1.1Columnpm10010mpCtrlmsaShutdownIndexread-onlycurrentIndex definition for the pm10010mpCtrlmsaShutdown table
1.3.6.1.4.1.20044.58.6.3.212.1.2Columnpm10010mpCtrlmsaShutdownPortnread-writecurrentLine MSA Shutdown :This OID enters a process to shutdown the MSA line module <Help > This control initiates a shutdown of the module
1.3.6.1.4.1.20044.58.7Nodepm10010mpri
1.3.6.1.4.1.20044.58.7.1Nodepm10010mpriTable
1.3.6.1.4.1.20044.58.7.1.1Tablepm10010mpRinvSfpTablenot-accessiblecurrentList of the SFPs on the selected module
1.3.6.1.4.1.20044.58.7.1.1.1Rowpm10010mpRinvSfpEntrynot-accessiblecurrentRow definition for the SFP table
1.3.6.1.4.1.20044.58.7.1.1.1.1Columnpm10010mpRinvSfpIndexread-onlycurrentIndex for SFP table
1.3.6.1.4.1.20044.58.7.1.1.1.2Columnpm10010mpRinvsfpread-onlycurrentInventory for the SFP: This OID contains the inventory for the SFP
1.3.6.1.4.1.20044.58.7.1.2Tablepm10010mpRinvLineTablenot-accessiblecurrentList of the XFPs on the selected module
1.3.6.1.4.1.20044.58.7.1.2.1Rowpm10010mpRinvLineEntrynot-accessiblecurrentRow definition for the XFP table
1.3.6.1.4.1.20044.58.7.1.2.1.1Columnpm10010mpRinvLineIndexread-onlycurrentIndex for XFP table
1.3.6.1.4.1.20044.58.7.1.2.1.2Columnpm10010mpRinvxfpLineread-onlycurrentInventory for the XFP: This OID contains the inventory for the XFP
1.3.6.1.4.1.20044.58.7.2Scalarpm10010mpRinvReloadInventoryread-writecurrentReload the inventory: This OID triggers an inventory reload.
1.3.6.1.4.1.20044.58.7.3Scalarpm10010mpRinvHwPlatformread-onlycurrentHW platform description: This OID contains the description of the Hardware platform.
1.3.6.1.4.1.20044.58.7.4Scalarpm10010mpRinvModulePlatformread-onlycurrentModule platform description: This OID contains the description of the Module.
1.3.6.1.4.1.20044.58.7.5Scalarpm10010mpRinvSwPlatformread-onlycurrentSW platform description: This OID contains the description of the Software platform.
1.3.6.1.4.1.20044.58.7.6Scalarpm10010mpRinvGwPlatformread-onlycurrentGW platform desciption: This OID contains the description of the Gateware platform.
1.3.6.1.4.1.20044.58.8Nodepm10010mpdownload
1.3.6.1.4.1.20044.58.8.1Nodepm10010mpDwlOther
1.3.6.1.4.1.20044.58.8.1.0Nodepm10010mpDwlrestartProcess
1.3.6.1.4.1.20044.58.8.1.0.1Scalarpm10010mpDwlWarmRestartProcessedread-onlycurrentWarm Restart :This OID indicates that the module last restart was a Warm RESTART
1.3.6.1.4.1.20044.58.8.1.0.2Scalarpm10010mpDwlColdRestartProcessedread-onlycurrentCold Restart :This OID indicates that the module last restart was a Cold RESTART
1.3.6.1.4.1.20044.58.8.1.1Nodepm10010mpDwlswBanksUsed
1.3.6.1.4.1.20044.58.8.1.1.1Scalarpm10010mpDwlSwBank1Usedread-onlycurrentSW bank 1 active :This OID indicates the module is working on SW bank 1 <Help> This status indicates if the SW bank 1 is active or standby
1.3.6.1.4.1.20044.58.8.1.1.2Scalarpm10010mpDwlSwBank2Usedread-onlycurrentSW bank 2 active :This OID indicates the module is working on SW bank 2 <Help> This status indicates if the SW bank 2 is active or standby
1.3.6.1.4.1.20044.58.8.1.1.5Scalarpm10010mpDwlSwBank1Notemptyread-onlycurrentSW bank 1 loaded :This OID indicates a software is loaded in SW bank 1 <Help> This status indicates if the SW bank 1 contains SW package
1.3.6.1.4.1.20044.58.8.1.1.6Scalarpm10010mpDwlSwBank2Notemptyread-onlycurrentSW bank 2 loaded :This OID indicates a software is loaded in SW bank 2 <Help> This status indicates if the SW bank 2 contains SW package
1.3.6.1.4.1.20044.58.8.1.2Nodepm10010mpDwlgwBanksUsed
1.3.6.1.4.1.20044.58.8.1.2.1Scalarpm10010mpDwlGwBank1Usedread-onlycurrentGW bank 1 active :This OID indicates the module is working on GW bank 1 <Help> This status indicates if the GW bank 1 is active or standby
1.3.6.1.4.1.20044.58.8.1.2.2Scalarpm10010mpDwlGwBank2Usedread-onlycurrentGW bank 2 active :This OID indicates the module is working on GW bank 2
1.3.6.1.4.1.20044.58.8.1.2.3Scalarpm10010mpDwlGwBank3Usedread-onlycurrentGW bank 3 active :This OID indicates the module is working on GW bank 3 <Help> This status indicates if the GW bank 3 is active or standby
1.3.6.1.4.1.20044.58.8.1.2.4Scalarpm10010mpDwlGwBank4Usedread-onlycurrentGW bank 4 active :This OID indicates the module is working on GW bank 4
1.3.6.1.4.1.20044.58.8.1.2.5Scalarpm10010mpDwlGwBank1Notemptyread-onlycurrentGW bank 1 loaded :This OID indicates a gateware is loaded in GW bank 1 <Help> This status indicates if the GW bank 1 contains GW package
1.3.6.1.4.1.20044.58.8.1.2.6Scalarpm10010mpDwlGwBank2Notemptyread-onlycurrentGW bank 2 loaded :This OID indicates a gateware is loaded in GW bank 2
1.3.6.1.4.1.20044.58.8.1.2.7Scalarpm10010mpDwlGwBank3Notemptyread-onlycurrentGW bank 3 loaded :This OID indicates a gateware is loaded in GW bank 3 <Help> This status indicates if the GW bank 3 contains GW package
1.3.6.1.4.1.20044.58.8.1.2.8Scalarpm10010mpDwlGwBank4Notemptyread-onlycurrentGW bank 4 loaded :This OID indicates a gateware is loaded in GW bank 4
1.3.6.1.4.1.20044.58.8.2Nodepm10010mpDwlClient
1.3.6.1.4.1.20044.58.8.3Nodepm10010mpDwlLine
1.3.6.1.4.1.20044.58.9Nodepm10010mpConfig
1.3.6.1.4.1.20044.58.9.1Nodepm10010mpCfgAccessCAisCsf
1.3.6.1.4.1.20044.58.9.1.1Tablepm10010mpCfgClientcaiscsfTablenot-accessiblecurrentList of Article
1.3.6.1.4.1.20044.58.9.1.1.1Rowpm10010mpCfgClientcaiscsfEntrynot-accessiblecurrentRow definition for the accessCAisCsf table
1.3.6.1.4.1.20044.58.9.1.1.1.1Columnpm10010mpCfgClientcaiscsfIndexread-onlycurrentIndex definition for the clientcaiscsf table
1.3.6.1.4.1.20044.58.9.1.1.1.3Columnpm10010mpCfgReservePortnread-writecurrentCAIS mode on Client Port :This register enables/disables port laser shutdown on CAIS insertion condition
1.3.6.1.4.1.20044.58.9.2Nodepm10010mpCfgStartup
1.3.6.1.4.1.20044.58.9.2.1Tablepm10010mpCfgClientStartupTablenot-accessiblecurrentList of Article
1.3.6.1.4.1.20044.58.9.2.1.1Rowpm10010mpCfgClientStartupEntrynot-accessiblecurrentRow definition for the startup table
1.3.6.1.4.1.20044.58.9.2.1.1.1Columnpm10010mpCfgClientStartupIndexread-onlycurrentIndex definition for the clientStartup table
1.3.6.1.4.1.20044.58.9.2.1.1.3Columnpm10010mpCfgSystConfPortPortnread-writecurrentDefault Settings on Client Port :This register configures the default initialisation settings on the port.
1.3.6.1.4.1.20044.58.9.2.1.1.4Columnpm10010mpCfgNetConfPortPortnread-writecurrentDefault Settings on Client Port :This register configures the default initialisation settings on the port.
1.3.6.1.4.1.20044.58.9.2.1.1.14Columnpm10010mpCfgOptionsPortPortnread-writecurrentDefault Options on Client Port :This register configures the default options on the port.
1.3.6.1.4.1.20044.58.9.2.2Tablepm10010mpCfgLineStartupTablenot-accessiblecurrentList of Article
1.3.6.1.4.1.20044.58.9.2.2.1Rowpm10010mpCfgLineStartupEntrynot-accessiblecurrentRow definition for the startup table
1.3.6.1.4.1.20044.58.9.2.2.1.1Columnpm10010mpCfgLineStartupIndexread-onlycurrentIndex definition for the lineStartup table
1.3.6.1.4.1.20044.58.9.2.2.1.3Columnpm10010mpCfgSystConfLinePortnread-writecurrentDefault Settings on Line :This register configures the default initialisation settings on Line
1.3.6.1.4.1.20044.58.9.2.2.1.14Columnpm10010mpCfgOptionsLinePortnread-writecurrentDefault Options on Line :This register configures the default options on the line
1.3.6.1.4.1.20044.58.9.2.3Tablepm10010mpCfgXfpTablenot-accessiblecurrentList of Article
1.3.6.1.4.1.20044.58.9.2.3.1Rowpm10010mpCfgXfpEntrynot-accessiblecurrentRow definition for the startup table
1.3.6.1.4.1.20044.58.9.2.3.1.1Columnpm10010mpCfgXfpIndexread-onlycurrentIndex definition for the xfp table
1.3.6.1.4.1.20044.58.9.2.3.1.3Columnpm10010mpCfgSystConfMsaLinePortnread-writecurrentDefault settings on MSA :This register configures the default initialisation settings on MSA
1.3.6.1.4.1.20044.58.9.2.4Tablepm10010mpCfgClientOtxtlhTablenot-accessiblecurrentList of Article
1.3.6.1.4.1.20044.58.9.2.4.1Rowpm10010mpCfgClientOtxtlhEntrynot-accessiblecurrentRow definition for the startup table
1.3.6.1.4.1.20044.58.9.2.4.1.1Columnpm10010mpCfgClientOtxtlhIndexread-onlycurrentIndex definition for the clientOtxtlh table
1.3.6.1.4.1.20044.58.9.2.4.1.3Columnpm10010mpCfgControlsPortnread-writedeprecatedDefaut Client settings :This register configures the start-up settings on the ports
1.3.6.1.4.1.20044.58.9.2.4.1.6Columnpm10010mpCfgClientPwrLaserPortnread-writecurrentDefaut Client output Power :This register configures the start-up output power of the client transceiver (Unit = dBm)
1.3.6.1.4.1.20044.58.9.2.4.1.7Columnpm10010mpCfgClientFCurrentPortnread-writecurrentDefault Client transceiver Channel :This register configures the start-up laser channel of the client transceiver
1.3.6.1.4.1.20044.58.9.2.4.1.8Columnpm10010mpCfgClientGridCurrentPortnread-writecurrentDefault Client transceiver Grid :This register configures the start-up laser grid of the client transceiver
1.3.6.1.4.1.20044.58.9.2.4.1.9Columnpm10010mpCfgClientFoPortnread-writecurrentDefault Client first Frequency :This register configures the start-up first frequency of the client transceiver
1.3.6.1.4.1.20044.58.9.3Nodepm10010mpCfgLabels
1.3.6.1.4.1.20044.58.9.3.1Tablepm10010mpCfgLabelclientTablenot-accessiblecurrentList of Article
1.3.6.1.4.1.20044.58.9.3.1.1Rowpm10010mpCfgLabelclientEntrynot-accessiblecurrentRow definition for the labels table
1.3.6.1.4.1.20044.58.9.3.1.1.1Columnpm10010mpCfgLabelclientIndexread-onlycurrentIndex definition for the labelclient table
1.3.6.1.4.1.20044.58.9.3.1.1.3Columnpm10010mpCfgLabelclientPortnread-writecurrentDefault settings on the label of the Ports :These registers configures the default initialisation settings of the labels of the ports.
1.3.6.1.4.1.20044.58.9.3.2Tablepm10010mpCfgLabellineTablenot-accessiblecurrentList of Article
1.3.6.1.4.1.20044.58.9.3.2.1Rowpm10010mpCfgLabellineEntrynot-accessiblecurrentRow definition for the labels table
1.3.6.1.4.1.20044.58.9.3.2.1.1Columnpm10010mpCfgLabellineIndexread-onlycurrentIndex definition for the labelline table
1.3.6.1.4.1.20044.58.9.3.2.1.3Columnpm10010mpCfgLabellinePortnread-writecurrentDefault settings on the label of the lines :These registers configures the default initialisation settings of the labels of the lines.
1.3.6.1.4.1.20044.58.9.4Nodepm10010mpCfgStartuptlh
1.3.6.1.4.1.20044.58.9.4.1Tablepm10010mpCfgOtxtlhTablenot-accessiblecurrentList of Article
1.3.6.1.4.1.20044.58.9.4.1.1Rowpm10010mpCfgOtxtlhEntrynot-accessiblecurrentRow definition for the startuptlh table
1.3.6.1.4.1.20044.58.9.4.1.1.1Columnpm10010mpCfgOtxtlhIndexread-onlycurrentIndex definition for the otxtlh table
1.3.6.1.4.1.20044.58.9.4.1.1.6Columnpm10010mpCfgLinePwrLaserPortnread-writecurrentDefaut Line output Power :This register configures the start-up output power of the Line tranceiver (Unit = dBm)
1.3.6.1.4.1.20044.58.9.4.1.1.7Columnpm10010mpCfgLineFCurrentPortnread-writecurrentDefault Line transceiver Tx Channel :This register configures the start-up laser channel of the Line Tx transceiver
1.3.6.1.4.1.20044.58.9.4.1.1.8Columnpm10010mpCfgLineGridCurrentPortnread-writecurrentDefault Line transceiver Grid :This register configures the start-up laser grid of the Line transceiver
1.3.6.1.4.1.20044.58.9.4.1.1.9Columnpm10010mpCfgFPortnread-writecurrentDefault Line TRX lowest Freq :This register configures the start-up lowest frequency of the Line transceiver
1.3.6.1.4.1.20044.58.9.4.1.1.10Columnpm10010mpCfgRxLineFCurrentPortnread-writecurrentDefault Line transceiver Rx Channel :This register configures the start-up laser channel of the Line Rx transceiver
1.3.6.1.4.1.20044.58.9.5Nodepm10010mpCfgOther
1.3.6.1.4.1.20044.58.9.5.1Nodepm10010mptablemoduleOther
1.3.6.1.4.1.20044.58.9.5.1.2Scalarpm10010mpCfgmoderead-writecurrentDefault settings on Module :This register selects the configuration mode of the module
1.3.6.1.4.1.20044.58.9.5.1.3Scalarpm10010mpCfgfanLowSpeedThresholdread-writecurrentDefault settings on Module :This register selects the speed threshold of the fan's
1.3.6.1.4.1.20044.58.9.5.1.4Scalarpm10010mpCfgfanHighSpeedThresholdread-writecurrentDefault settings on Module :This register selects the speed threshold of the fan's
1.3.6.1.4.1.20044.58.9.6Nodepm10010mpCfgStartuptablefive
1.3.6.1.4.1.20044.58.9.6.1Tablepm10010mpCfgOtxtlhcapabilitiesTablenot-accessiblecurrentList of Article
1.3.6.1.4.1.20044.58.9.6.1.1Rowpm10010mpCfgOtxtlhcapabilitiesEntrynot-accessiblecurrentRow definition for the startuptablefive table
1.3.6.1.4.1.20044.58.9.6.1.1.1Columnpm10010mpCfgOtxtlhcapabilitiesIndexread-onlycurrentIndex definition for the otxtlhcapabilities table
1.3.6.1.4.1.20044.58.9.6.1.1.3Columnpm10010mpCfgComponentTypePortnread-onlycurrentComponent parameters :This OID defines the component parameters
1.3.6.1.4.1.20044.58.9.6.1.1.4Columnpm10010mpCfgMiscellaneousPortnread-onlycurrentMiscellaneous default settings :This OID defines the miscellaneous parameters
1.3.6.1.4.1.20044.58.9.6.1.1.5Columnpm10010mpCfgFirstChannelPortnread-onlycurrentNumber of the first channel of the component :This OID defines the first channel number of the PM
1.3.6.1.4.1.20044.58.9.6.1.1.6Columnpm10010mpCfgLastChannelPortnread-onlycurrentNumber of the last channel of the component :This OID defines the last channel number of the PM
1.3.6.1.4.1.20044.58.9.6.1.1.7Columnpm10010mpCfgGridPortnread-onlycurrentGrid value of the component :This OID defines the grid of the PM
1.3.6.1.4.1.20044.58.9.257Scalarpm10010mpCfgWriteConfigurationread-writecurrentWrite configuration to module:This OID writes the complete configuration to the module
1.3.6.1.4.1.20044.58.10Nodepm10010mptraps
1.3.6.1.4.1.20044.58.10.2Scalarpm10010mptrapPortNumberread-onlycurrentLast port which generates a trap
1.3.6.1.4.1.20044.58.10.3Scalarpm10010mptrapLineNumberread-onlycurrentLast Line which generates a trap
1.3.6.1.4.1.20044.58.10.4Scalarpm10010mptrapBoardNumberread-onlycurrentLast module which generates a trap
1.3.6.1.4.1.20044.58.10.30Notificationpm10010mpLineTrapNotUrgentGoesOncurrentNot urgent Line default is activated
1.3.6.1.4.1.20044.58.10.31Notificationpm10010mpLineTrapNotUrgentGoesOffcurrentNot urgent Line default disappeared
1.3.6.1.4.1.20044.58.10.32Notificationpm10010mpLineTrapUrgentGoesOncurrentUrgent Line default is activated
1.3.6.1.4.1.20044.58.10.33Notificationpm10010mpLineTrapUrgentGoesOffcurrentUrgent Line default disappeared
1.3.6.1.4.1.20044.58.10.34Notificationpm10010mpLineTrapCritGoesOncurrentCritical Line default is activated
1.3.6.1.4.1.20044.58.10.35Notificationpm10010mpLineTrapCritGoesOffcurrentCritical Line default disappeared
1.3.6.1.4.1.20044.58.10.40Notificationpm10010mpClientTrapNotUrgentGoesOncurrentNot urgent client default is activated
1.3.6.1.4.1.20044.58.10.41Notificationpm10010mpClientTrapNotUrgentGoesOffcurrentNot urgent client default disappeared
1.3.6.1.4.1.20044.58.10.42Notificationpm10010mpClientTrapUrgentGoesOncurrentUrgent client default is activated
1.3.6.1.4.1.20044.58.10.43Notificationpm10010mpClientTrapUrgentGoesOffcurrentUrgent client default disappeared
1.3.6.1.4.1.20044.58.10.44Notificationpm10010mpClientTrapCritGoesOncurrentCritical client default is activated
1.3.6.1.4.1.20044.58.10.45Notificationpm10010mpClientTrapCritGoesOffcurrentCritical client default disappeared
1.3.6.1.4.1.20044.58.10.50Notificationpm10010mpPowerTrapUrgentGoesOncurrentUrgent power supply default is activated
1.3.6.1.4.1.20044.58.10.51Notificationpm10010mpPowerTrapUrgentGoesOffcurrentUrgent power supply default disappeared
1.3.6.1.4.1.20044.58.11Nodepm10010mpMonitoring
1.3.6.1.4.1.20044.58.11.1Nodepm10010mpMonOther
1.3.6.1.4.1.20044.58.11.1.3Nodepm10010mpMonRmon
1.3.6.1.4.1.20044.58.11.2Nodepm10010mpMonClient
1.3.6.1.4.1.20044.58.11.2.4Nodepm10010mpMonClientRmonCounter
1.3.6.1.4.1.20044.58.11.2.4.16Tablepm10010mpMonupRmonBytesCounterClientInputTablenot-accessiblecurrentList of pm10010mpMonupRmonBytesCounterClientInput Article
1.3.6.1.4.1.20044.58.11.2.4.16.1Rowpm10010mpMonupRmonBytesCounterClientInputEntrynot-accessiblecurrentRow definition for the pm10010mpMonupRmonBytesCounterClientInput table
1.3.6.1.4.1.20044.58.11.2.4.16.1.1Columnpm10010mpMonupRmonBytesCounterClientInputIndexread-onlycurrentIndex definition for the pm10010mpMonupRmonBytesCounterClientInput table
1.3.6.1.4.1.20044.58.11.2.4.16.1.2Columnpm10010mpMonupRmonBytesCounterClientInputValuePortnread-onlycurrentClient Input Bytes :This counter is increased each time a data byte is received on the client port <Help> This counter gives the number of bytes received on th…
1.3.6.1.4.1.20044.58.11.2.4.16.1.3Columnpm10010mpMonupRmonBytesCounterClientInputErrorPortnread-onlycurrentBytes Counter Error :This OID when set indicates the Bytes counter value is invalid on client port
1.3.6.1.4.1.20044.58.11.2.4.16.1.4Columnpm10010mpMonupRmonBytesCounterClientInputOverloadPortnread-onlycurrentBytes Counter Overload :This OID when set indicates a Bytes counter overload on client port
1.3.6.1.4.1.20044.58.11.2.4.32Tablepm10010mpMonupRmonCrcErrorsCounterClientInputTablenot-accessiblecurrentList of pm10010mpMonupRmonCrcErrorsCounterClientInput Article
1.3.6.1.4.1.20044.58.11.2.4.32.1Rowpm10010mpMonupRmonCrcErrorsCounterClientInputEntrynot-accessiblecurrentRow definition for the pm10010mpMonupRmonCrcErrorsCounterClientInput table
1.3.6.1.4.1.20044.58.11.2.4.32.1.1Columnpm10010mpMonupRmonCrcErrorsCounterClientInputIndexread-onlycurrentIndex definition for the pm10010mpMonupRmonCrcErrorsCounterClientInput table
1.3.6.1.4.1.20044.58.11.2.4.32.1.2Columnpm10010mpMonupRmonCrcErrorsCounterClientInputValuePortnread-onlycurrentClient Input B1/CRC Errors :This counter is increased each time a B1/CRC error is detected on the client port <Help> This counter gives the number of B1/CRC Er…
1.3.6.1.4.1.20044.58.11.2.4.32.1.3Columnpm10010mpMonupRmonCrcErrorsCounterClientInputErrorPortnread-onlycurrentCRC Errors Counter Error :This OID when set indicates the CRC Errors counter value is invalid on client port
1.3.6.1.4.1.20044.58.11.2.4.32.1.4Columnpm10010mpMonupRmonCrcErrorsCounterClientInputOverloadPortnread-onlycurrentCRC Errors Counter Overload :This OID when set indicates a CRC Errors counter overload on client port
1.3.6.1.4.1.20044.58.11.2.4.48Tablepm10010mpMonupRmonPacketsCounterClientInputTablenot-accessiblecurrentList of pm10010mpMonupRmonPacketsCounterClientInput Article
1.3.6.1.4.1.20044.58.11.2.4.48.1Rowpm10010mpMonupRmonPacketsCounterClientInputEntrynot-accessiblecurrentRow definition for the pm10010mpMonupRmonPacketsCounterClientInput table
1.3.6.1.4.1.20044.58.11.2.4.48.1.1Columnpm10010mpMonupRmonPacketsCounterClientInputIndexread-onlycurrentIndex definition for the pm10010mpMonupRmonPacketsCounterClientInput table
1.3.6.1.4.1.20044.58.11.2.4.48.1.2Columnpm10010mpMonupRmonPacketsCounterClientInputValuePortnread-onlycurrentClient Input Packets :This counter is increased each time a packet is received on the client port <Help> This counter gives the number of packets received on t…
1.3.6.1.4.1.20044.58.11.2.4.48.1.3Columnpm10010mpMonupRmonPacketsCounterClientInputErrorPortnread-onlycurrentPackets Counter Error :This OID when set indicates the Packets counter value is invalid on client port
1.3.6.1.4.1.20044.58.11.2.4.48.1.4Columnpm10010mpMonupRmonPacketsCounterClientInputOverloadPortnread-onlycurrentPackets Counter Overload :This OID when set indicates a Packets counter overload on client port
1.3.6.1.4.1.20044.58.11.2.4.64Tablepm10010mpMonupRmonBroadcastCounterClientInputTablenot-accessiblecurrentList of pm10010mpMonupRmonBroadcastCounterClientInput Article
1.3.6.1.4.1.20044.58.11.2.4.64.1Rowpm10010mpMonupRmonBroadcastCounterClientInputEntrynot-accessiblecurrentRow definition for the pm10010mpMonupRmonBroadcastCounterClientInput table
1.3.6.1.4.1.20044.58.11.2.4.64.1.1Columnpm10010mpMonupRmonBroadcastCounterClientInputIndexread-onlycurrentIndex definition for the pm10010mpMonupRmonBroadcastCounterClientInput table
1.3.6.1.4.1.20044.58.11.2.4.64.1.2Columnpm10010mpMonupRmonBroadcastCounterClientInputValuePortnread-onlycurrentClient Input Broadcast Packets :This counter is increased each time a broadcast packet is received on the client port <Help> This counter gives the number of B…
1.3.6.1.4.1.20044.58.11.2.4.64.1.3Columnpm10010mpMonupRmonBroadcastCounterClientInputErrorPortnread-onlycurrentBroadcast Counter Error :This OID when set indicates the Broadcast counter value is invalid on client port
1.3.6.1.4.1.20044.58.11.2.4.64.1.4Columnpm10010mpMonupRmonBroadcastCounterClientInputOverloadPortnread-onlycurrentBroadcast Counter Overload :This OID when set indicates a Broadcast counter overload on client port
1.3.6.1.4.1.20044.58.11.2.4.80Tablepm10010mpMonupRmonMulticastCounterClientInputTablenot-accessiblecurrentList of pm10010mpMonupRmonMulticastCounterClientInput Article
1.3.6.1.4.1.20044.58.11.2.4.80.1Rowpm10010mpMonupRmonMulticastCounterClientInputEntrynot-accessiblecurrentRow definition for the pm10010mpMonupRmonMulticastCounterClientInput table
1.3.6.1.4.1.20044.58.11.2.4.80.1.1Columnpm10010mpMonupRmonMulticastCounterClientInputIndexread-onlycurrentIndex definition for the pm10010mpMonupRmonMulticastCounterClientInput table
1.3.6.1.4.1.20044.58.11.2.4.80.1.2Columnpm10010mpMonupRmonMulticastCounterClientInputValuePortnread-onlycurrentClient Input Multicast Packets :This counter is increased each time a Multicast packet is received on the client port <Help> This counter gives the number of M…
1.3.6.1.4.1.20044.58.11.2.4.80.1.3Columnpm10010mpMonupRmonMulticastCounterClientInputErrorPortnread-onlycurrentMulticast Counter Error :This OID when set indicates the Multicast counter value is invalid on client port
1.3.6.1.4.1.20044.58.11.2.4.80.1.4Columnpm10010mpMonupRmonMulticastCounterClientInputOverloadPortnread-onlycurrentMulticast Counter Overload :This OID when set indicates a Multicast counter overload on client port
1.3.6.1.4.1.20044.58.11.2.4.96Tablepm10010mpMonupRmonPauseFrameCounterClientInputTablenot-accessiblecurrentList of pm10010mpMonupRmonPauseFrameCounterClientInput Article
1.3.6.1.4.1.20044.58.11.2.4.96.1Rowpm10010mpMonupRmonPauseFrameCounterClientInputEntrynot-accessiblecurrentRow definition for the pm10010mpMonupRmonPauseFrameCounterClientInput table
1.3.6.1.4.1.20044.58.11.2.4.96.1.1Columnpm10010mpMonupRmonPauseFrameCounterClientInputIndexread-onlycurrentIndex definition for the pm10010mpMonupRmonPauseFrameCounterClientInput table
1.3.6.1.4.1.20044.58.11.2.4.96.1.2Columnpm10010mpMonupRmonPauseFrameCounterClientInputValuePortnread-onlycurrentClient Input Pause Frames :This counter is increased each time a Pause frame is received on the client port <Help> This counter gives the number of Pause frame…
1.3.6.1.4.1.20044.58.11.2.4.96.1.3Columnpm10010mpMonupRmonPauseFrameCounterClientInputErrorPortnread-onlycurrentPause Counter Error :This OID when set indicates the Pause counter value is invalid on client port
1.3.6.1.4.1.20044.58.11.2.4.96.1.4Columnpm10010mpMonupRmonPauseFrameCounterClientInputOverloadPortnread-onlycurrentPause Counter Overload :This OID when set indicates a Pause counter overload on client port
Type Definitions
NameSyntaxStatusDescription
Pm10010mpAdjustValueINTEGER { otxadjustvalue0(0), otxadjustvalue1(1), otxadjustvalue2(2), otxadjustvalue3(3), otxadjustvalue4(4), otxadjustvalue5(5), otxadjustvalue6(6), otxadjustvalue7(7), otxadjustvalue8(8), otxadjustvalue9(9), otxadjustvalue10(10) }currentDifferent values in Adjust mode on OTX-TLH on client and line ports
Pm10010mpClientProtocolINTEGER { protocolclientvalue0(0), protocolclientvalue1(1), protocolclientvalue2(2), protocolclientvalue3(3), protocolclientvalue4(4), protocolclientvalue5(5), protocolclientvalue6(6), protocolclientvalue7(7), protocolclientvalue8(8) }currentDifferent values on the protocol on the client ports
Pm10010mpMultiRateINTEGER { rate100Mhz(0), rate250Mhz(1), rate500Mhz(2), rate1Ghz(3) }currentdifferent rate for a client port
Pm10010mpOrxChannelINTEGERcurrentChannel selection on transceiver Rx line ports
Pm10010mpOtxChannelINTEGERcurrentChannel selection on transceiver Tx line ports
Pm10010mpOtxGridINTEGER { otxgrid200(200), otxgrid100(100), otxgrid50(50) }currentDifferent grids on OTX-TLH on client and line ports
Pm10010mpOtxModeINTEGER { otx80mode(1), otx60mode(2), otxadjustmode(4) }currentDifferent modes on OTX-TLH on client and line ports
Pm10010mpProtocolModeINTEGER { protocolmodevalue0(0), protocolmodevalue1(1), protocolmodevalue2(2), protocolmodevalue3(3) }currentDifferent values on the protocol mode