EKINOPS-Pm10010ulh-MIB

1019 objects
Creation.
OIDNameAccessStatusDescription
1.3.6.1.4.1.20044.80IdentitymodulePm10010ulhCreation.
1.3.6.1.4.1.20044.80.2Nodepm10010ulhalarms
1.3.6.1.4.1.20044.80.2.1Nodepm10010ulhAlmOther
1.3.6.1.4.1.20044.80.2.1.1Nodepm10010ulhAlmOtherNurg
1.3.6.1.4.1.20044.80.2.1.1.2Nodepm10010ulhAlmsynthAlm2
1.3.6.1.4.1.20044.80.2.1.1.2.1Scalarpm10010ulhAlmConfTableSaveread-onlycurrentPM Configuration Save :This OID is at 1 during the saving of a new configuration table in the module Flash memory. <Condtype> CONF_TABLE_SAVE <Probcause> infor…
1.3.6.1.4.1.20044.80.2.1.1.2.2Scalarpm10010ulhAlmInvUploadread-onlycurrentInventory Upload :This OID is at 1 during the uploading of PM inventory information. <Condtype> INV_UPLOAD <Probcause> informationalStatus(1000) <Alarmtype> ot…
1.3.6.1.4.1.20044.80.2.1.1.2.3Scalarpm10010ulhAlmConfTableLoadread-onlycurrentPM Configuration Load :This OID is at 1 during the loading of configuration tables in the modules RAM. <Condtype> CONF_TABLE_LOAD <Probcause> informationalStat…
1.3.6.1.4.1.20044.80.2.1.1.2.4Scalarpm10010ulhAlmCorrelatOffread-onlycurrentNot Used :This OID, when set, indicates that alarm correlation is not being performed. <Condtype> CORRELAT_OFF <Probcause> informationalStatus(1000) <Alarmtype…
1.3.6.1.4.1.20044.80.2.1.1.2.5Scalarpm10010ulhAlmMaintenanceOnread-onlycurrentMaintenance Mode :This OID indicates that the RM is in maintenance mode. <Help> This alarm indicates that the maintenance mode is enabled on the PM <Condtype> …
1.3.6.1.4.1.20044.80.2.1.2Nodepm10010ulhAlmOtherUrg
1.3.6.1.4.1.20044.80.2.1.2.336Nodepm10010ulhAlmmodFanFail
1.3.6.1.4.1.20044.80.2.1.2.336.1Scalarpm10010ulhAlmFanFailread-onlycurrentFan Module Failure :This OID indicates that the FAN unit inside the module is in fail condition <Help> This alarm indicates that the FAN is in a fail condition…
1.3.6.1.4.1.20044.80.2.1.2.336.2Scalarpm10010ulhAlmFanHighSpeedread-onlycurrentFan High Speed :This OID indicates the fan is blowing at high speed <Help> This alarm indicates the fan is blowing at high speed <Condtype> FAN_HIGH_SPEED <Pro…
1.3.6.1.4.1.20044.80.2.1.3Nodepm10010ulhAlmOtherCrit
1.3.6.1.4.1.20044.80.2.1.3.0Nodepm10010ulhAlmsynthAlm0
1.3.6.1.4.1.20044.80.2.1.3.0.2Scalarpm10010ulhAlmFailFanread-onlycurrentFan Fail :This OID is at 1 when any fail occurs on the fan tray <Help> This alarm indicates that the Fan tray module is in a failure condition <Condtype> FAIL_…
1.3.6.1.4.1.20044.80.2.1.3.0.9Scalarpm10010ulhAlmModGlobFailread-onlycurrentModule Failure :This OID is set on detection of a failure originating from the RM <Help> This alarm is set on detection of a failure originating from the equip…
1.3.6.1.4.1.20044.80.2.1.3.0.15Scalarpm10010ulhAlmDefFuseAread-onlycurrentFuse A Fail :This OID indicates that the fuse of the power input A is in fail condition <Help> Status of the Fuse A <Condtype> DEF_FUSE_A <Probcause> powerProb…
1.3.6.1.4.1.20044.80.2.1.3.0.16Scalarpm10010ulhAlmDefFuseBread-onlycurrentFuse B Fail :This OID indicates that the fuse of the power input B is in fail condition <Help> Status of the Fuse B <Condtype> DEF_FUSE_B <Probcause> powerProb…
1.3.6.1.4.1.20044.80.2.1.3.72Nodepm10010ulhAlmclientModuleState
1.3.6.1.4.1.20044.80.2.1.3.72.1Scalarpm10010ulhAlmCfpInitializeread-onlycurrentClient Trscv Initialize :This OID indicates the Client Trscv initialization is in progress <Help> Status indicating the Client Trscv initialization is in progr…
1.3.6.1.4.1.20044.80.2.1.3.72.2Scalarpm10010ulhAlmCfpLowPowerread-onlycurrentClient Trscv Low Power :This OID indicates the Client Trscv is in low power state <Help> Status indicating the Client Trscv is in low power state <Condtype> CF…
1.3.6.1.4.1.20044.80.2.1.3.72.3Scalarpm10010ulhAlmCfpHighPowerUpread-onlycurrentClient Trscv High Power Up :This OID indicates the Client Trscv is leaving Low Power state <Help> Status indicating the Client Trscv is leaving Low Power state…
1.3.6.1.4.1.20044.80.2.1.3.72.4Scalarpm10010ulhAlmCfpTxOffread-onlycurrentClient Trscv Laser Shutdown :This OID indicates the Client Trscv Laser is OFF <Help> Status indicating the Client Trscv Laser is OFF <Condtype> CFP_TX_OFF <Pro…
1.3.6.1.4.1.20044.80.2.1.3.72.5Scalarpm10010ulhAlmCfpTxTurnOnread-onlycurrentClient Trscv Laser Turn On :This OID indicates the Client Trscv is turning on its laser <Help> Status indicating the Client Trscv is turning on its laser <Cond…
1.3.6.1.4.1.20044.80.2.1.3.72.6Scalarpm10010ulhAlmCfpReadyread-onlycurrentClient Trscv Ready :This OID indicates the Client Trscv is ready to operate <Help> Status indicating the Client Trscv is ready to operate <Condtype> CFP_READY …
1.3.6.1.4.1.20044.80.2.1.3.72.7Scalarpm10010ulhAlmCfpFaultread-onlycurrentClient Trscv Fault :This OID indicates the Client Trscv is in Fault state <Help> Status indicating the Client Trscv is in Fault state <Condtype> CFP_FAULT <Pro…
1.3.6.1.4.1.20044.80.2.1.3.72.8Scalarpm10010ulhAlmCfpTxTurnOffread-onlycurrentClient Trscv Laser Turn Off :This OID indicates the Client Trscv is turning off its laser <Help> Status indicating the Client Trscv is turning off its laser <C…
1.3.6.1.4.1.20044.80.2.1.3.72.9Scalarpm10010ulhAlmCfpHighPowerDownread-onlycurrentClient Trscv High Power Down :This OID indicates the Client Trscv is entering Low Power state <Help> Status indicating the Client Trscv is entering Low Power s…
1.3.6.1.4.1.20044.80.2.1.3.73Nodepm10010ulhAlmclientModuleGeneralStatus
1.3.6.1.4.1.20044.80.2.1.3.73.4Scalarpm10010ulhAlmCfpOutOfAlignmentread-onlycurrentClient Trscv Out Of Alignment :This OID indicates an Out of alignment on the Client Trscv Host Interface <Help> Alarm indicating an Out of alignment on the Cli…
1.3.6.1.4.1.20044.80.2.1.3.73.5Scalarpm10010ulhAlmCfpRxNetworkLolread-onlycurrentClient Trscv Rx Network Loss Of Lock :This OID indicates of Loss of Lock is dected on the Client Trscv Rx Network interface <Help> Alarm indicating of Loss of …
1.3.6.1.4.1.20044.80.2.1.3.73.6Scalarpm10010ulhAlmCfpRxLosread-onlycurrentClient Trscv Loss Of Signal :This OID indicates a Loss of Signal is detected on the Client Trscv <Help> Alarm indicating a Loss of Signal is detected on the Cl…
1.3.6.1.4.1.20044.80.2.1.3.73.7Scalarpm10010ulhAlmCfpTxHostLolread-onlycurrentClient Trscv Tx Host Loss Of Lock :This OID indicates of Loss of Lock is detected on the Client Trscv Tx Host interface <Help> Alarm indicating of Loss of Lock…
1.3.6.1.4.1.20044.80.2.1.3.73.8Scalarpm10010ulhAlmCfpTxLosfread-onlycurrentClient Trscv Loss Of Signal Functionality :This OID indicates a Loss of Signal functionality is detected on the Client Trscv <Help> Alarm indicating a Loss of …
1.3.6.1.4.1.20044.80.2.1.3.73.9Scalarpm10010ulhAlmCfpTxCmuLolread-onlycurrentClient Trscv CMU Loss Of Lock :This OID indicates a Clock Multiplier Unit Loss of Lock is detected on the Client Trscv <Help> Alarm indicating a Clock Multipli…
1.3.6.1.4.1.20044.80.2.1.3.73.10Scalarpm10010ulhAlmCfpTxJitterPllLolread-onlycurrentClient Trscv Tx Jitter PLL Loss Of Lock :This OID indicates a Tx Jitter PLL Loss of Lock is dtected on the Client Trscv <Help> Alarm indicating a Tx Jitter PLL…
1.3.6.1.4.1.20044.80.2.1.3.73.11Scalarpm10010ulhAlmCfpLossOfRefclkread-onlycurrentClient Trscv Loss Of Ref Clock :This OID indicates a Loss of Reference clock is detected on the Client Trscv <Help> Alarm indicating a Loss of Reference clock …
1.3.6.1.4.1.20044.80.2.1.3.73.14Scalarpm10010ulhAlmCfpHwInterlockread-onlycurrentClient Trscv Hardware Interlock :This OID indicates the Client Trscv power is higher than the cooling capacity <Help> Alarm indicating the Client Trscv power i…
1.3.6.1.4.1.20044.80.2.1.3.74Nodepm10010ulhAlmclientGlobalAlarmSummary
1.3.6.1.4.1.20044.80.2.1.3.74.1Scalarpm10010ulhAlmCfpSoftGlobAlarmTestread-onlycurrentClient Trscv Global Alarm SW Test :This OID indicates the Client Trscv Global Alarm This OID is raised by SW request for test purpose <Help> Status indicating …
1.3.6.1.4.1.20044.80.2.1.3.74.7Scalarpm10010ulhAlmCfpNetworkLaneAlarmWarning2read-onlycurrentClient Trscv Network Alarm And Warning 2 :This OID indicates at least one DDM is detected on the Client Trscv Network Interface <Help> Synthesis alarm indicati…
1.3.6.1.4.1.20044.80.2.1.3.74.8Scalarpm10010ulhAlmCfpModuleStateread-onlycurrentClient Trscv Module State :This OID indicates the Client Trscv module state <Help> Synthesis alarm indicating the Client Trscv module state <Condtype> CFP_MODU…
1.3.6.1.4.1.20044.80.2.1.3.74.9Scalarpm10010ulhAlmCfpModuleGeneralStatusread-onlycurrentClient Trscv General Status :This OID indicates the Client Trscv module general status <Help> Synthesis alarm indicating the Client Trscv module general status…
1.3.6.1.4.1.20044.80.2.1.3.74.10Scalarpm10010ulhAlmCfpModuleFaultread-onlycurrentClient Trscv Module Fault :This OID indicates at least one Fault is detected on the Client Trscv module <Help> Synthesis alarm indicating at least one Fault is…
1.3.6.1.4.1.20044.80.2.1.3.74.11Scalarpm10010ulhAlmCfpModuleAlarmWarning1read-onlycurrentClient Trscv Module Alarm And Warning 1 :This OID indicates at least one DDM This OID is detected on the Client Trscv module <Help> Synthesis alarm indicating …
1.3.6.1.4.1.20044.80.2.1.3.74.12Scalarpm10010ulhAlmCfpModuleAlarmWarning2read-onlycurrentClient Trscv Module Alarm And Warning 2 :This OID indicates at least one DDM is detected on the Client Trscv module <Help> Synthesis alarm indicating at least …
1.3.6.1.4.1.20044.80.2.1.3.74.13Scalarpm10010ulhAlmCfpNetworkLaneAlarmWarning1read-onlycurrentClient Trscv Network Alarm And Warning 1 :This OID indicates at least one DDM is detected on the Client Trscv Network Interface <Help> Synthesis alarm indicati…
1.3.6.1.4.1.20044.80.2.1.3.74.14Scalarpm10010ulhAlmCfpNetworkLaneFaultStatusread-onlycurrentClient Trscv Network Fault And Status :This OID indicates at least one Fault or Status is detected on the Client Trscv Network Interface <Help> Synthesis alarm…
1.3.6.1.4.1.20044.80.2.1.3.74.15Scalarpm10010ulhAlmCfpHostLaneFaultStatusread-onlycurrentClient Trscv Host Fault And Status :This OID indicates at least one Fault or Status is detected on the Client Trscv Host Interface <Help> Synthesis alarm indic…
1.3.6.1.4.1.20044.80.2.1.3.74.16Scalarpm10010ulhAlmCfpGlobAlarmAssertionread-onlycurrentClient Trscv Global Alarm :This OID indicates at least one Fault or Status is detected on the Client Trscv module <Help> Synthesis alarm indicating at least on…
1.3.6.1.4.1.20044.80.2.1.3.78Nodepm10010ulhAlmmsaModuleState
1.3.6.1.4.1.20044.80.2.1.3.78.1Scalarpm10010ulhAlmMsaInitializeread-onlycurrentLine Trscv Initialize :This OID indicates the Line Trscv initialization is in progress <Help> Status indicating the Line Trscv initialization is in progress <C…
1.3.6.1.4.1.20044.80.2.1.3.78.2Scalarpm10010ulhAlmMsaLowPowerread-onlycurrentLine Trscv Low Power :This OID indicates the Line Trscv is in low power state <Help> Status indicating the Line Trscv is in low power state <Condtype> MSA_LOW_…
1.3.6.1.4.1.20044.80.2.1.3.78.3Scalarpm10010ulhAlmMsaHighPowerUpread-onlycurrentLine Trscv High Power Up :This OID indicates the Line Trscv is leaving Low Power state <Help> Status indicating the Line Trscv is leaving Low Power state <Cond…
1.3.6.1.4.1.20044.80.2.1.3.78.4Scalarpm10010ulhAlmMsaTxOffread-onlycurrentLine Trscv Laser Shutdown :This OID indicates the Line Trscv Laser is OFF <Help> Status indicating the Line Trscv Laser is OFF <Condtype> MSA_TX_OFF <Probcause…
1.3.6.1.4.1.20044.80.2.1.3.78.5Scalarpm10010ulhAlmMsaTxTurnOnread-onlycurrentLine Trscv Laser Turn On :This OID indicates the Line Trscv is turning on its laser <Help> Status indicating the Line Trscv is turning on its laser <Condtype> …
1.3.6.1.4.1.20044.80.2.1.3.78.6Scalarpm10010ulhAlmMsaReadyread-onlycurrentLine Trscv Ready :This OID indicates the Line Trscv is ready to operate <Help> Status indicating the Line Trscv is ready to operate <Condtype> MSA_READY <Probc…
1.3.6.1.4.1.20044.80.2.1.3.78.7Scalarpm10010ulhAlmMsaFaultread-onlycurrentLine Trscv Fault :This OID indicates the Line Trscv is in Fault state <Help> Status indicating the Line Trscv is in Fault state <Condtype> MSA_FAULT <Probcause…
1.3.6.1.4.1.20044.80.2.1.3.78.8Scalarpm10010ulhAlmMsaTxTurnOffread-onlycurrentLine Trscv Laser Turn Off :This OID indicates the Line Trscv is turning off its laser <Help> Status indicating the Line Trscv is turning off its laser <Condtyp…
1.3.6.1.4.1.20044.80.2.1.3.78.9Scalarpm10010ulhAlmMsaHighPowerDownread-onlycurrentLine Trscv High Power Down :This OID indicates the Line Trscv is entering Low Power state <Help> Status indicating the Line Trscv is entering Low Power state <…
1.3.6.1.4.1.20044.80.2.1.3.79Nodepm10010ulhAlmmsaModuleGeneralStatus
1.3.6.1.4.1.20044.80.2.1.3.79.4Scalarpm10010ulhAlmMsaOutOfAlignmentread-onlycurrentLine Trscv Out Of Alignment :This OID indicates an Out of alignment on the Line Trscv Host Interface <Help> Alarm indicating an Out of alignment on the Line Tr…
1.3.6.1.4.1.20044.80.2.1.3.79.5Scalarpm10010ulhAlmMsaRxNetworkLolread-onlycurrentLine Trscv Rx Network Loss Of Lock :This OID indicates of Loss of Lock is detected on the Line Trscv Rx Network interface <Help> Alarm indicating of Loss of Lo…
1.3.6.1.4.1.20044.80.2.1.3.79.6Scalarpm10010ulhAlmMsaRxLosread-onlycurrentLine Trscv Loss Of Signal :This OID indicates a Loss of Signal is detected on the Line Trscv <Help> Alarm indicating a Loss of Signal is detected on the Line T…
1.3.6.1.4.1.20044.80.2.1.3.79.7Scalarpm10010ulhAlmMsaTxHostLolread-onlycurrentLine Trscv Tx Host Loss Of Lock :This OID indicates of Loss of Lock is detected on the Line Trscv Tx Host interface <Help> Alarm indicating of Loss of Lock is …
1.3.6.1.4.1.20044.80.2.1.3.79.8Scalarpm10010ulhAlmMsaTxLosfread-onlycurrentLine Trscv Loss Of Signal Functionality :This OID indicates a Loss of Signal functionality is detected on the Line Trscv <Help> Alarm indicating a Loss of Sign…
1.3.6.1.4.1.20044.80.2.1.3.79.9Scalarpm10010ulhAlmMsaTxCmuLolread-onlycurrentLine Trscv CMU Loss Of Lock :This OID indicates a Clock Multiplier Unit Loss of Lock is detected on the Line Trscv <Help> Alarm indicating a Clock Multiplier U…
1.3.6.1.4.1.20044.80.2.1.3.79.10Scalarpm10010ulhAlmMsaTxJitterPllLolread-onlycurrentLine Trscv Tx Jitter PLL Loss Of Lock :This OID indicates a Tx Jitter PLL Loss of Lock is detected on the Line Trscv <Help> Alarm indicating a Tx Jitter PLL Lo…
1.3.6.1.4.1.20044.80.2.1.3.79.11Scalarpm10010ulhAlmMsaLossOfRefclkread-onlycurrentLine Trscv Loss Of Ref Clock :This OID indicates a Loss of Reference clock is detected on the Line Trscv <Help> Alarm indicating a Loss of Reference clock is d…
1.3.6.1.4.1.20044.80.2.1.3.79.14Scalarpm10010ulhAlmMsaHwInterlockread-onlycurrentLine Trscv Hardware Interlock :This OID indicates the Line Trscv power is higher than the cooling capacity <Help> Alarm indicating the Line Trscv power is high…
1.3.6.1.4.1.20044.80.2.1.3.80Nodepm10010ulhAlmmsaGlobalAlarmSummary
1.3.6.1.4.1.20044.80.2.1.3.80.1Scalarpm10010ulhAlmMsaSoftGlobAlarmTestread-onlycurrentLine Trscv Global Alarm SW Test :This OID indicates the Line Trscv Global alarm This OID is raised by SW request for test purpose <Help> Status indicating the …
1.3.6.1.4.1.20044.80.2.1.3.80.6Scalarpm10010ulhAlmMsaNetworkHostAlarmStatusread-onlycurrentLine Trscv Network/Host Alarm Status :This OID indicates the state of the Network and Host interface of the Line Trscv <Help> Synthesis alarm indicating the al…
1.3.6.1.4.1.20044.80.2.1.3.80.7Scalarpm10010ulhAlmMsaNetworkLaneAlarmWarning2read-onlycurrentLine Trscv Network Alarm And Warning 2 :This OID indicates at least one DDM This OID is detected on the Line Trscv Network Interface <Help> Synthesis alarm ind…
1.3.6.1.4.1.20044.80.2.1.3.80.8Scalarpm10010ulhAlmMsaModuleStateread-onlycurrentLine Trscv Module State :This OID indicates the Line Trscv module state <Help> Synthesis alarm indicating the Line Trscv module state <Condtype> MSA_MODULE_STA…
1.3.6.1.4.1.20044.80.2.1.3.80.9Scalarpm10010ulhAlmMsaModuleGeneralStatusread-onlycurrentLine Trscv General Status :This OID indicates the Line Trscv module general <Help> Synthesis alarm indicating the Line Trscv module general status <Condtype> M…
1.3.6.1.4.1.20044.80.2.1.3.80.10Scalarpm10010ulhAlmModuleFaultread-onlycurrentLine Trscv Module Fault :This OID indicates at least one Fault is detected on the Line Trscv module <Help> Synthesis alarm indicating at least one Fault is det…
1.3.6.1.4.1.20044.80.2.1.3.80.11Scalarpm10010ulhAlmMsaModuleAlarmWarning1read-onlycurrentLine Trscv Module Alarm And Warning 1 :This OID indicates at least one DDM is detected on the Line Trscv module <Help> Synthesis alarm indicating at least one …
1.3.6.1.4.1.20044.80.2.1.3.80.12Scalarpm10010ulhAlmMsaModuleAlarmWarning2read-onlycurrentLine Trscv Module Alarm And Warning 2 :This OID indicates at least one DDM is detected on the Line Trscv module <Help> Synthesis alarm indicating at least one …
1.3.6.1.4.1.20044.80.2.1.3.80.13Scalarpm10010ulhAlmMsaNetworkLaneAlarmWarning1read-onlycurrentLine Trscv Network Alarm And Warning 1 :This OID indicates at least one DDM is detected on the Line Trscv Network Interface <Help> Synthesis alarm indicating a…
1.3.6.1.4.1.20044.80.2.1.3.80.14Scalarpm10010ulhAlmMsaNetworkLaneFaultStatusread-onlycurrentLine Trscv Network Fault And Status :This OID indicates at least one Fault or Status is detected on the Line Trscv Network Interface <Help> Synthesis alarm ind…
1.3.6.1.4.1.20044.80.2.1.3.80.15Scalarpm10010ulhAlmMsaHostLaneFaultStatusread-onlycurrentLine Trscv Host Fault And Status :This OID indicates at least one Fault or Status is detected on the Line Trscv Host Interface <Help> Synthesis alarm indicatin…
1.3.6.1.4.1.20044.80.2.1.3.80.16Scalarpm10010ulhAlmMsaGlobAlarmAssertionread-onlycurrentLine Trscv Global Alarm :This OID indicates at least one Fault or Status is detected on the Line Trscv module <Help> Synthesis alarm indicating at least one Al…
1.3.6.1.4.1.20044.80.2.1.3.81Nodepm10010ulhAlmmsaNetworkTxAlignment
1.3.6.1.4.1.20044.80.2.1.3.81.12Scalarpm10010ulhAlmNetTxTimingFaultread-onlycurrentLine Trscv Network Tx Timing Fault :This OID indicates a Tx Timing Fault is detected on the Line Trscv Network interface <Help> Alarm indicating a Tx Timing Fa…
1.3.6.1.4.1.20044.80.2.1.3.81.13Scalarpm10010ulhAlmNetTxReferenceClockFaultread-onlycurrentLine Trscv Network Tx Ref Clock Fault :This OID indicates a Tx Reference Clock Fault is detected on the Line Trscv Network interface <Help> Alarm indicating a …
1.3.6.1.4.1.20044.80.2.1.3.81.14Scalarpm10010ulhAlmNetTxCmuLockFaultread-onlycurrentLine Trscv Network Tx CMU Lock Fault :This OID indicates a Tx Clock Multiplier Unit Lock Fault is detected on the Line Trscv Network interface <Help> Alarm ind…
1.3.6.1.4.1.20044.80.2.1.3.81.15Scalarpm10010ulhAlmNetTxOutOfAlignmentread-onlycurrentLine Trscv Network Tx Out Of Alignment :This OID indicates a Tx Out of Alignment is detected on the Line Trscv Network interface <Help> Alarm indicating a Tx O…
1.3.6.1.4.1.20044.80.2.1.3.81.16Scalarpm10010ulhAlmNetTxLossOfAlignmentread-onlycurrentLine Trscv Network Tx Loss Of Alignment :This OID indicates a Tx Loss of Alignment is detected on the Line Trscv Network interface <Help> Alarm indicating a Tx…
1.3.6.1.4.1.20044.80.2.1.3.82Nodepm10010ulhAlmmsaNetworkRxAlignment
1.3.6.1.4.1.20044.80.2.1.3.82.12Scalarpm10010ulhAlmNetRxTimingFaultread-onlycurrentLine Trscv Network Rx Timing Fault :This OID indicates a Rx Timing Fault is detected on the Line Trscv Network interface <Help> Alarm indicating a Rx Timing Fa…
1.3.6.1.4.1.20044.80.2.1.3.82.13Scalarpm10010ulhAlmNetRxOutOfAlignmentread-onlycurrentLine Trscv Network Rx Out Of Alignment :This OID indicates a Rx Out of Alignment is detected on the Line Trscv Network interface <Help> Alarm indicating a Rx O…
1.3.6.1.4.1.20044.80.2.1.3.82.14Scalarpm10010ulhAlmNetRxLossOfAlignmentread-onlycurrentLine Trscv Network Rx Loss Of Alignment :This OID indicates a Rx Loss of Alignment is detected on the Line Trscv Network interface <Help> Alarm indicating a Rx…
1.3.6.1.4.1.20044.80.2.1.3.82.15Scalarpm10010ulhAlmNetRxModemLockFaultread-onlycurrentLine Trscv Network Rx Modem Lock Fault :This OID indicates a Rx Modem Lock Fault is detected on the Line Trscv Network interface <Help> Alarm indicating a Rx M…
1.3.6.1.4.1.20044.80.2.1.3.82.16Scalarpm10010ulhAlmNetRxModemSyncDetectFaultread-onlycurrentLine Trscv Network Rx Modem Sync Detect Fault :This OID indicates a Rx Modem Synchronisation Detection Fault is detected on the Line Trscv Network interface <H…
1.3.6.1.4.1.20044.80.2.1.3.83Nodepm10010ulhAlmmsaNetworkHostNetworkAlarmSummary
1.3.6.1.4.1.20044.80.2.1.3.83.11Scalarpm10010ulhAlmNetworkTxAlignmentread-onlycurrentLine Trscv Network Tx Alignment :This OID indicates a Tx Alignment Fault is detected on the Line Trscv Network interface <Help> Synthesis Alarm indicating a Tx…
1.3.6.1.4.1.20044.80.2.1.3.83.12Scalarpm10010ulhAlmNetworkRxAlignmentread-onlycurrentLine Trscv Network Rx Alignment :This OID indicates a Rx Alignment Fault is detected on the Line Trscv Network interface <Help> Synthesis Alarm indicating a Rx…
1.3.6.1.4.1.20044.80.2.1.3.83.13Scalarpm10010ulhAlmNetworkRxOtnread-onlycurrentLine Trscv Network Rx OTN :This OID indicates a Rx OTN Fault is detected on the Line Trscv Network interface <Help> Synthesis Alarm indicating a Rx OTN Fault i…
1.3.6.1.4.1.20044.80.2.1.3.83.14Scalarpm10010ulhAlmHostRxAlignmentread-onlycurrentLine Trscv Host Rx Alignment :This OID indicates a Rx Alignment Fault is detected on the Line Trscv Host interface <Help> Synthesis Alarm indicating a Rx Align…
1.3.6.1.4.1.20044.80.2.1.3.83.15Scalarpm10010ulhAlmHostTxAlignmentread-onlycurrentLine Trscv Host Tx Alignment :This OID indicates a Tx Alignment Fault is detected on the Line Trscv Host interface <Help> Synthesis Alarm indicating a Tx Align…
1.3.6.1.4.1.20044.80.2.1.3.83.16Scalarpm10010ulhAlmHostTxOtnStatusread-onlycurrentLine Trscv Host Tx OTN :This OID indicates a Tx OTN Fault is detected on the Line Trscv Host interface <Help> Synthesis Alarm indicating a Tx OTN Fault is dete…
1.3.6.1.4.1.20044.80.2.1.3.84Nodepm10010ulhAlmmsaHostTxAlignment
1.3.6.1.4.1.20044.80.2.1.3.84.13Scalarpm10010ulhAlmHostTxDeskewLockFaultread-onlycurrentLine Trscv Host Tx Deskew Lock Fault :This OID indicates a Tx Deskew Lock Fault is detected on the Line Trscv Host interface <Help> Alarm indicating a Tx Deske…
1.3.6.1.4.1.20044.80.2.1.3.84.14Scalarpm10010ulhAlmHostTxOutOfAlignmentread-onlycurrentLine Trscv Host Tx Out Of Alignment :This OID indicates a Tx Out of Alignment is detected on the Line Trscv Host interface <Help> Alarm indicating a Tx Out of …
1.3.6.1.4.1.20044.80.2.1.3.84.15Scalarpm10010ulhAlmHostTxLossOfAlignmentread-onlycurrentLine Trscv Host Tx Loss Of Alignment :This OID indicates a Tx Loss of Alignment is detected on the Line Trscv Host interface <Help> Alarm indicating a Tx Loss …
1.3.6.1.4.1.20044.80.2.1.3.84.16Scalarpm10010ulhAlmHostTxCdrLockFaultread-onlycurrentLine Trscv Host Tx CDR Lock Fault :This OID indicates a Tx Clock Data Recovery Lock Fault is detected on the Line Trscv Host interface <Help> Alarm indicating …
1.3.6.1.4.1.20044.80.2.1.3.85Nodepm10010ulhAlmmsaHostRxAlignment
1.3.6.1.4.1.20044.80.2.1.3.85.14Scalarpm10010ulhAlmHostRxCmuLockFaultread-onlycurrentLine Trscv Host Rx CMU Lock Fault :This OID indicates a Rx Clock Multiplier Unit Lock Fault is detected on the Line Trscv Host interface <Help> Alarm indicatin…
1.3.6.1.4.1.20044.80.2.1.3.85.15Scalarpm10010ulhAlmHostRxOutOfAlignmentread-onlycurrentLine Trscv Host Rx Out Of Alignment :This OID indicates a Rx Out of Alignment is detected on the Line Trscv Host interface <Help> Alarm indicating a Rx Out of …
1.3.6.1.4.1.20044.80.2.1.3.85.16Scalarpm10010ulhAlmHostRxLossOfAlignmentread-onlycurrentLine Trscv Host Rx Loss Of Alignment :This OID indicates a Rx Loss of Alignment is detected on the Line Trscv Host interface <Help> Alarm indicating a Rx Loss …
1.3.6.1.4.1.20044.80.2.2Nodepm10010ulhAlmClient
1.3.6.1.4.1.20044.80.2.2.1Nodepm10010ulhAlmClientNurg
1.3.6.1.4.1.20044.80.2.2.1.88Tablepm10010ulhAlmclientNetworkLaneAlarmWarningTablenot-accessiblecurrentList of pm10010ulhAlmclientNetworkLaneAlarmWarning Article
1.3.6.1.4.1.20044.80.2.2.1.88.1Rowpm10010ulhAlmclientNetworkLaneAlarmWarningEntrynot-accessiblecurrentRow definition for the pm10010ulhAlmclientNetworkLaneAlarmWarning table
1.3.6.1.4.1.20044.80.2.2.1.88.1.1Columnpm10010ulhAlmclientNetworkLaneAlarmWarningIndexread-onlycurrentIndex definition for the pm10010ulhAlmclientNetworkLaneAlarmWarning table
1.3.6.1.4.1.20044.80.2.2.1.88.1.2Columnpm10010ulhAlmClientRxPowerLowAlarmPortnread-onlycurrentClient Trscv Rx Power Low Alarm :This OID indicates that the Trscv input power is lower than the threshold value written in the Trscv EEPROM <Help> Alarm indic…
1.3.6.1.4.1.20044.80.2.2.1.88.1.3Columnpm10010ulhAlmClientRxPowerLowWarningPortnread-onlycurrentClient Trscv Rx Power Low Warning :This OID indicates that the Trscv input power is lower than the threshold value written in the Trscv EEPROM <Help> Warning i…
1.3.6.1.4.1.20044.80.2.2.1.88.1.4Columnpm10010ulhAlmClientRxPowerHighWarningPortnread-onlycurrentClient Trscv Rx Power High Warning :This OID indicates that the Trscv input power is higher than the threshold value written in the Trscv EEPROM <Help> Warning…
1.3.6.1.4.1.20044.80.2.2.1.88.1.5Columnpm10010ulhAlmClientRxPowerHighAlarmPortnread-onlycurrentClient Trscv Rx Power High Alarm :This OID indicates that the Trscv input power is higher than the threshold value written in the Trscv EEPROM <Help> Alarm ind…
1.3.6.1.4.1.20044.80.2.2.1.88.1.6Columnpm10010ulhAlmLaserTempLowAlarmPortnread-onlycurrentClient Trscv Laser Temp Low Alarm :This OID indicates that the Trscv Laser Temperature is lower than the threshold value written in the Trscv EEPROM <Help> Ala…
1.3.6.1.4.1.20044.80.2.2.1.88.1.7Columnpm10010ulhAlmClientLaserTempLowWarningPortnread-onlycurrentClient Trscv Laser Temp Low Warning :This OID indicates that the Trscv Laser Temperature is lower than the threshold value written in the Trscv EEPROM <Help> W…
1.3.6.1.4.1.20044.80.2.2.1.88.1.8Columnpm10010ulhAlmClientLaserTempHighWarningPortnread-onlycurrentClient Trscv Laser Temp High Warning :This OID indicates that the Trscv Laser Temperature is higher than the threshold value written in the Trscv EEPROM <Help>…
1.3.6.1.4.1.20044.80.2.2.1.88.1.9Columnpm10010ulhAlmClientLaserTempHighAlarmPortnread-onlycurrentClient Trscv Laser Temp High Alarm :This OID indicates that the Trscv Laser Temperature is higher than the threshold value written in the Trscv EEPROM <Help> A…
1.3.6.1.4.1.20044.80.2.2.1.88.1.10Columnpm10010ulhAlmClientTxPowerLowAlarmPortnread-onlycurrentClient Trscv Tx Power Low Alarm :This OID indicates that the Trscv output power is lower than the threshold value written in the Trscv EEPROM <Help> Alarm indi…
1.3.6.1.4.1.20044.80.2.2.1.88.1.11Columnpm10010ulhAlmClientTxPowerLowWarningPortnread-onlycurrentClient Trscv Tx Power Low Warning :This OID indicates that the Trscv output power is lower than the threshold value written in the Trscv EEPROM <Help> Warning …
1.3.6.1.4.1.20044.80.2.2.1.88.1.12Columnpm10010ulhAlmClientTxPowerHighWarningPortnread-onlycurrentClient Trscv Tx Power High Warning :This OID indicates that the Trscv output power is higher than the threshold value written in the Trscv EEPROM <Help> Warnin…
1.3.6.1.4.1.20044.80.2.2.1.88.1.13Columnpm10010ulhAlmClientTxPowerHighAlarmPortnread-onlycurrentClient Trscv Tx Power High Alarm :This OID indicates that the Trscv output power is higher than the threshold value written in the Trscv EEPROM <Help> Alarm in…
1.3.6.1.4.1.20044.80.2.2.1.88.1.14Columnpm10010ulhAlmClientBiasLowAlarmPortnread-onlycurrentClient Trscv Bias Low Alarm :This OID indicates that the Trscv laser bias current is lower than the threshold value written in the Trscv EEPROM <Help> Alarm in…
1.3.6.1.4.1.20044.80.2.2.1.88.1.15Columnpm10010ulhAlmClientBiasLowWarningPortnread-onlycurrentClient Trscv Bias Low Warning :This OID indicates that the Trscv laser bias current is lower than the threshold value written in the Trscv EEPROM <Help> Warnin…
1.3.6.1.4.1.20044.80.2.2.1.88.1.16Columnpm10010ulhAlmClientBiasHighWarningPortnread-onlycurrentClient Trscv Bias High Warning :This OID indicates that the Trscv laser bias current is higher than the threshold value written in the Trscv EEPROM <Help> Warn…
1.3.6.1.4.1.20044.80.2.2.1.88.1.17Columnpm10010ulhAlmClientBiasHighAlarmPortnread-onlycurrentClient Trscv Bias High Alarm :This OID indicates that the Trscv laser bias current is higher than the threshold value written in the Trscv EEPROM <Help> Alarm …
1.3.6.1.4.1.20044.80.2.2.1.272Tablepm10010ulhAlmclientSfpWarnDdmTablenot-accessiblecurrentList of pm10010ulhAlmclientSfpWarnDdm Article
1.3.6.1.4.1.20044.80.2.2.1.272.1Rowpm10010ulhAlmclientSfpWarnDdmEntrynot-accessiblecurrentRow definition for the pm10010ulhAlmclientSfpWarnDdm table
1.3.6.1.4.1.20044.80.2.2.1.272.1.1Columnpm10010ulhAlmclientSfpWarnDdmIndexread-onlycurrentIndex definition for the pm10010ulhAlmclientSfpWarnDdm table
1.3.6.1.4.1.20044.80.2.2.1.272.1.2Columnpm10010ulhAlmTxPwLowWngPortnread-onlycurrentClient Trscv Tx Power Low Warning :This OID indicates that the Trscv output power is lower than the threshold value written in the Trscv EEPROM <Help> Warning …
1.3.6.1.4.1.20044.80.2.2.1.272.1.3Columnpm10010ulhAlmTxPwrHighWngPortnread-onlycurrentClient Trscv Tx Power High Warning :This OID indicates that the Trscv output power is higher than the threshold value written in the Trscv EEPROM <Help> Warnin…
1.3.6.1.4.1.20044.80.2.2.1.272.1.4Columnpm10010ulhAlmTxBiasLowWngPortnread-onlycurrentClient Trscv Bias Low Warning :This OID indicates that the Trscv laser bias current is lower than the threshold value written in the Trscv EEPROM <Help> Warnin…
1.3.6.1.4.1.20044.80.2.2.1.272.1.5Columnpm10010ulhAlmTxBiasHighWngPortnread-onlycurrentClient Trscv Bias High Warning :This OID indicates that the Trscv laser bias current is higher than the threshold value written in the Trscv EEPROM <Help> Warn…
1.3.6.1.4.1.20044.80.2.2.1.272.1.6Columnpm10010ulhAlmVccLowWngPortnread-onlycurrentClient Trscv Power Supply Low Warning :This OID indicates that the Trscv power supply is lower than the threshold value written in the Trscv EEPROM <Help> Warn…
1.3.6.1.4.1.20044.80.2.2.1.272.1.7Columnpm10010ulhAlmVccHighWngPortnread-onlycurrentClient Trscv Power Supply High Warning :This OID indicates that the Trscv power supply is higher than the threshold value written in the Trscv EEPROM <Help> Wa…
1.3.6.1.4.1.20044.80.2.2.1.272.1.8Columnpm10010ulhAlmTempLowWngPortnread-onlycurrentClient Trscv Temp Low Warning :This OID indicates that the Trscv temperature is lower than the threshold value written in the Trscv EEPROM <Help> Warning indic…
1.3.6.1.4.1.20044.80.2.2.1.272.1.9Columnpm10010ulhAlmTempHighWngPortnread-onlycurrentClient Trscv Temp High Warning :This OID indicates that the Trscv temperature is higher than the threshold value written in the Trscv EEPROM <Help> Warning ind…
1.3.6.1.4.1.20044.80.2.2.1.272.1.16Columnpm10010ulhAlmRxPwrLowWngPortnread-onlycurrentClient Trscv Rx Power Low Warning :This OID indicates that the Trscv input power is lower than the threshold value written in the Trscv EEPROM <Help> Warning i…
1.3.6.1.4.1.20044.80.2.2.1.272.1.17Columnpm10010ulhAlmRxPwrHighWngPortnread-onlycurrentClient Trscv Rx Power High Warning :This OID indicates that the Trscv input power is higher than the threshold value written in the Trscv EEPROM <Help> Warning…
1.3.6.1.4.1.20044.80.2.2.2Nodepm10010ulhAlmClientUrg
1.3.6.1.4.1.20044.80.2.2.2.120Tablepm10010ulhAlmclientNetworkLaneFaultTablenot-accessiblecurrentList of pm10010ulhAlmclientNetworkLaneFault Article
1.3.6.1.4.1.20044.80.2.2.2.120.1Rowpm10010ulhAlmclientNetworkLaneFaultEntrynot-accessiblecurrentRow definition for the pm10010ulhAlmclientNetworkLaneFault table
1.3.6.1.4.1.20044.80.2.2.2.120.1.1Columnpm10010ulhAlmclientNetworkLaneFaultIndexread-onlycurrentIndex definition for the pm10010ulhAlmclientNetworkLaneFault table
1.3.6.1.4.1.20044.80.2.2.2.120.1.4Columnpm10010ulhAlmClientLaneRxFifoErrorPortnread-onlycurrentClient Network Lane Rx FIFO Error :This OID indicates a Rx FIFO Error on the Client Trscv Network Lane <Help> Alarm indicating a Rx FIFO Error on the Client Tr…
1.3.6.1.4.1.20044.80.2.2.2.120.1.5Columnpm10010ulhAlmClientLaneRxLolPortnread-onlycurrentClient Network Lane Rx Loss Of Lock :This OID indicates a Rx Loss of Lock on the Client Trscv Network Lane <Help> Alarm indicating a Rx Loss of Lock on the Cli…
1.3.6.1.4.1.20044.80.2.2.2.120.1.6Columnpm10010ulhAlmClientLaneRxLosPortnread-onlycurrentClient Network Lane Rx Loss Of Signal :This OID indicates a Rx Loss of Signal on the Client Trscv Network Lane <Help> Alarm indicating a Rx Loss of Signal on t…
1.3.6.1.4.1.20044.80.2.2.2.120.1.8Columnpm10010ulhAlmClientLaneTxLolPortnread-onlycurrentClient Network Lane Tx Loss Of Lock :This OID indicates a Tx Loss of Lock on the Client Trscv Network Lane <Help> Alarm indicating a Tx Loss of Lock on the Cli…
1.3.6.1.4.1.20044.80.2.2.2.120.1.9Columnpm10010ulhAlmClientLaneTxLosfPortnread-onlycurrentClient Network Lane Tx Loss Of Signal Functionality :This OID indicates a Tx Loss of Signal Functionality on the Client Trscv Network Lane <Help> Alarm indicat…
1.3.6.1.4.1.20044.80.2.2.2.120.1.15Columnpm10010ulhAlmClientLaneApdPowerSupplyPortnread-onlycurrentClient Network Lane APD Power Supply :This OID indicates an APD Power supply failure on the Client Trscv Network Lane <Help> Alarm indicating an APD Power supp…
1.3.6.1.4.1.20044.80.2.2.2.120.1.16Columnpm10010ulhAlmClientLaneWavelengthUnlockedPortnread-onlycurrentClient Network Lane Wavelength Unlock :This OID indicates a Wavelength unlock on the Client Trscv Network Lane <Help> Alarm indicating a Wavelength unlock on t…
1.3.6.1.4.1.20044.80.2.2.2.120.1.17Columnpm10010ulhAlmClientLaneTecFaultPortnread-onlycurrentClient Network Lane TEC Fault :This OID indicates a TEC Fault on the Client Trscv Network Lane <Help> Alarm indicating a TEC Fault on the Client Trscv Network …
1.3.6.1.4.1.20044.80.2.2.2.152Tablepm10010ulhAlmclientHostLaneFaultTablenot-accessiblecurrentList of pm10010ulhAlmclientHostLaneFault Article
1.3.6.1.4.1.20044.80.2.2.2.152.1Rowpm10010ulhAlmclientHostLaneFaultEntrynot-accessiblecurrentRow definition for the pm10010ulhAlmclientHostLaneFault table
1.3.6.1.4.1.20044.80.2.2.2.152.1.1Columnpm10010ulhAlmclientHostLaneFaultIndexread-onlycurrentIndex definition for the pm10010ulhAlmclientHostLaneFault table
1.3.6.1.4.1.20044.80.2.2.2.152.1.2Columnpm10010ulhAlmClientLossOfSyncPortnread-onlycurrentClient Frame Alignment Loss :This OID indicates the module is not aligned with the incoming Client signal <Help> Alarm indicating the module is not aligned wit…
1.3.6.1.4.1.20044.80.2.2.2.152.1.3Columnpm10010ulhAlmClientInputLossOfSigPortnread-onlycurrentClient Input Loss Of Signal :This OID indicates a Loss of Signal is detected on the Client Trscv <Help> Alarm indicating a Loss of Signal is detected on the Cl…
1.3.6.1.4.1.20044.80.2.2.2.152.1.4Columnpm10010ulhAlmClientLanesMarkerUnlockPortnread-onlycurrentClient Lanes Marker Unlock :This OID indicates the Client lanes marker alignment is not lock <Help> Alarm indicating the Client lanes marker alignment is not l…
1.3.6.1.4.1.20044.80.2.2.2.152.1.5Columnpm10010ulhAlmClientLanes6466UnlockPortnread-onlycurrentClient Lanes 64/66b Unlock :This OID indicates the Client 64/66b decoder is not lock <Help> Alarm indicating the Client 64/66b decoder is not lock <Condtype> C…
1.3.6.1.4.1.20044.80.2.2.2.152.1.6Columnpm10010ulhAlmClientLanesNotAlignedPortnread-onlycurrentClient Lanes Not Aligned :This OID indicates the Client lanes are not aligned <Help> Alarm indicating the Client lanes are not aligned <Condtype> CLIENT_LANES_…
1.3.6.1.4.1.20044.80.2.2.2.152.1.7Columnpm10010ulhAlmClientCsfDetectedPortnread-onlycurrentClient Signal Fail Detected :This OID indicates that a CSF has been detected on client port in the downstream direction <Help> This alarm indicates if a Client…
1.3.6.1.4.1.20044.80.2.2.2.152.1.10Columnpm10010ulhAlmClientTxHostLolPortnread-onlycurrentClient Host Lane Tx Loss Of Lock :This OID indicates a Tx Loss of Lock on the Client Trscv Host Lane <Help> Alarm indicating a Tx Loss of Lock on the Client Tr…
1.3.6.1.4.1.20044.80.2.2.2.152.1.11Columnpm10010ulhAlmClientLaneTxFifoErrorPortnread-onlycurrentClient Host Lane Tx FIFO Error :This OID indicates a Tx FIFO Error on the Client Trscv Host Lane <Help> Alarm indicating a Tx FIFO Error on the Client Trscv Ho…
1.3.6.1.4.1.20044.80.2.2.2.240Tablepm10010ulhAlmclientSfpAlmDdmTablenot-accessiblecurrentList of pm10010ulhAlmclientSfpAlmDdm Article
1.3.6.1.4.1.20044.80.2.2.2.240.1Rowpm10010ulhAlmclientSfpAlmDdmEntrynot-accessiblecurrentRow definition for the pm10010ulhAlmclientSfpAlmDdm table
1.3.6.1.4.1.20044.80.2.2.2.240.1.1Columnpm10010ulhAlmclientSfpAlmDdmIndexread-onlycurrentIndex definition for the pm10010ulhAlmclientSfpAlmDdm table
1.3.6.1.4.1.20044.80.2.2.2.240.1.2Columnpm10010ulhAlmTxPwrLowAlaPortnread-onlycurrentClient Trscv Tx Power Low :This OID indicates that the Trscv output power of port is lower than the threshold value written in the Trscv EEPROM <Help> Alarm in…
1.3.6.1.4.1.20044.80.2.2.2.240.1.3Columnpm10010ulhAlmTxPwrHighAlaPortnread-onlycurrentClient Trscv Tx Power High :This OID indicates that the Trscv output power of port is higher than the threshold value written in the Trscv EEPROM <Help> Alarm …
1.3.6.1.4.1.20044.80.2.2.2.240.1.4Columnpm10010ulhAlmTxBiasLowAlaPortnread-onlycurrentClient Trscv Bias Low :This OID indicates that the Trscv laser bias current of port is lower than the threshold value written in the Trscv EEPROM <Help> Alarm …
1.3.6.1.4.1.20044.80.2.2.2.240.1.5Columnpm10010ulhAlmTxBiasHighAlaPortnread-onlycurrentClient Trscv Bias High :This OID indicates that the Trscv laser bias current of port is higher than the threshold value written in the Trscv EEPROM <Help> Alar…
1.3.6.1.4.1.20044.80.2.2.2.240.1.6Columnpm10010ulhAlmVccLowAlaPortnread-onlycurrentClient Trscv Power Supply Low :This OID indicates that the Trscv power supply of port is lower than the threshold value written in the Trscv EEPROM <Help> Alar…
1.3.6.1.4.1.20044.80.2.2.2.240.1.7Columnpm10010ulhAlmVccHighAlaPortnread-onlycurrentClient Trscv Power Supply High :This OID indicates that the Trscv power supply of port is higher than the threshold value written in the Trscv EEPROM <Help> Al…
1.3.6.1.4.1.20044.80.2.2.2.240.1.8Columnpm10010ulhAlmTempLowAlaPortnread-onlycurrentClient Trscv Temp Low :This OID indicates that the Trscv temperature of port is lower than the threshold value written in the Trscv EEPROM <Help> Alarm indicat…
1.3.6.1.4.1.20044.80.2.2.2.240.1.9Columnpm10010ulhAlmTempHighAlaPortnread-onlycurrentClient Trscv Temp High :This OID indicates that the Trscv temperature of port is higher than the threshold value written in the Trscv EEPROM <Help> Alarm indic…
1.3.6.1.4.1.20044.80.2.2.2.240.1.16Columnpm10010ulhAlmRxPwrLowAlaPortnread-onlycurrentClient Trscv Rx Power Low :This OID indicates that the Trscv input power of port is lower than the threshold value written in the Trscv EEPROM <Help> Alarm ind…
1.3.6.1.4.1.20044.80.2.2.2.240.1.17Columnpm10010ulhAlmRxPwrHighAlaPortnread-onlycurrentClient Trscv Rx Power High :This OID indicates that the Trscv input power of port is higher than the threshold value written in the Trscv EEPROM <Help> Alarm i…
1.3.6.1.4.1.20044.80.2.2.3Nodepm10010ulhAlmClientCrit
1.3.6.1.4.1.20044.80.2.2.3.8Tablepm10010ulhAlmsynthAlmPortTablenot-accessiblecurrentList of pm10010ulhAlmsynthAlmPort Article
1.3.6.1.4.1.20044.80.2.2.3.8.1Rowpm10010ulhAlmsynthAlmPortEntrynot-accessiblecurrentRow definition for the pm10010ulhAlmsynthAlmPort table
1.3.6.1.4.1.20044.80.2.2.3.8.1.1Columnpm10010ulhAlmsynthAlmPortIndexread-onlycurrentIndex definition for the pm10010ulhAlmsynthAlmPort table
1.3.6.1.4.1.20044.80.2.2.3.8.1.2Columnpm10010ulhAlmSfpAbsentPortnread-onlycurrentClient Optical Module Absent :This OID indicates that the Transceiver is not present in the client port. <Help> This alarm indicates if the client transceiver …
1.3.6.1.4.1.20044.80.2.2.3.8.1.3Columnpm10010ulhAlmDdmAbsentPortnread-onlycurrentDDM Supported On Client Trscv :This OID indicates that the Client transceiver supports the Digital Diagnostic Monitoring function <Help> This status indicates …
1.3.6.1.4.1.20044.80.2.2.3.8.1.5Columnpm10010ulhAlmHwFailAccPortnread-onlycurrentClient HW Fail :This OID indicates a failure on client port, most probably caused by a HW issue. <Help> This alarm indicates a failure on client port, most pro…
1.3.6.1.4.1.20044.80.2.2.3.8.1.6Columnpm10010ulhAlmDwLsdPortnread-onlycurrentClient Trscv Laser Shutdown :This OID indicates the Client transceiver laser is shutdown <Help> This status indicates if the client transceiver laser is shutdo…
1.3.6.1.4.1.20044.80.2.2.3.8.1.7Columnpm10010ulhAlmClientLocalOosPortnread-onlycurrentLocal Client Port In Service :This OID indicates that the local Client port is In Service (1) or Out of Service (2) <Help> This status indicates if the local c…
1.3.6.1.4.1.20044.80.2.2.3.8.1.8Columnpm10010ulhAlmClientRemoteOosPortnread-onlycurrentRemote Client Port In Service :This OID indicates that the remote Client port is In Service (1) or Out of Service (2) <Help> This status indicates if the remot…
1.3.6.1.4.1.20044.80.2.2.3.8.1.9Columnpm10010ulhAlmDwCaisPortnread-onlycurrentClient AIS Inserted :This OID indicates a CAIS has been inserted on the output client port. <Help> This status indicates if a Client Alarm Indication Signal is…
1.3.6.1.4.1.20044.80.2.2.3.8.1.10Columnpm10010ulhAlmSfpDdmWarningPortnread-onlycurrentWarning On Client Trscv DDM :This OID indicates a warning is being received from the Client Transceiver DDM <Help> This alarm indicates if a DDM Warning has be…
1.3.6.1.4.1.20044.80.2.2.3.8.1.11Columnpm10010ulhAlmSfpDdmAlmPortnread-onlycurrentAlarm On Client Trscv DDM :This OID indicates an alarm is being received from the Client Transceiver DDM <Help> This alarm indicates if a DDM Alarm has been de…
1.3.6.1.4.1.20044.80.2.2.3.8.1.13Columnpm10010ulhAlmFailAccPortnread-onlycurrentClient Access Fail :This OID indicates a failure on the Client port <Help> This alarm indicates a failure on the Client port <Condtype> FAIL_ACC_1 <Probcause> …
1.3.6.1.4.1.20044.80.2.2.3.8.1.17Columnpm10010ulhAlmUpCsfPortnread-onlycurrentClient Signal Fail Inserted :This OID indicates a CSF has been inserted in the upstream client port. <Help> This status indicates if a Client Signal Fail is cu…
1.3.6.1.4.1.20044.80.2.3Nodepm10010ulhAlmLine
1.3.6.1.4.1.20044.80.2.3.1Nodepm10010ulhAlmLineNurg
1.3.6.1.4.1.20044.80.2.3.1.184Tablepm10010ulhAlmlineNetworkLaneAlarmWarning1Tablenot-accessiblecurrentList of pm10010ulhAlmlineNetworkLaneAlarmWarning1 Article
1.3.6.1.4.1.20044.80.2.3.1.184.1Rowpm10010ulhAlmlineNetworkLaneAlarmWarning1Entrynot-accessiblecurrentRow definition for the pm10010ulhAlmlineNetworkLaneAlarmWarning1 table
1.3.6.1.4.1.20044.80.2.3.1.184.1.1Columnpm10010ulhAlmlineNetworkLaneAlarmWarning1Indexread-onlycurrentIndex definition for the pm10010ulhAlmlineNetworkLaneAlarmWarning1 table
1.3.6.1.4.1.20044.80.2.3.1.184.1.2Columnpm10010ulhAlmLineRxPowerLowAlarmPortnread-onlycurrentLine Trscv Rx Power Low Alarm :This OID indicates that the Trscv input power is lower than the threshold value written in the Trscv EEPROM <Help> Alarm indicat…
1.3.6.1.4.1.20044.80.2.3.1.184.1.3Columnpm10010ulhAlmLineRxPowerLowWarningPortnread-onlycurrentLine Trscv Rx Power Low Warning :This OID indicates that the Trscv input power is lower than the threshold value written in the Trscv EEPROM <Help> Warning ind…
1.3.6.1.4.1.20044.80.2.3.1.184.1.4Columnpm10010ulhAlmLineRxPowerHighWarningPortnread-onlycurrentLine Trscv Rx Power High Warning :This OID indicates that the Trscv input power is higher than the threshold value written in the Trscv EEPROM <Help> Warning i…
1.3.6.1.4.1.20044.80.2.3.1.184.1.5Columnpm10010ulhAlmLineRxPowerHighAlarmPortnread-onlycurrentLine Trscv Rx Power High Alarm :This OID indicates that the Trscv input power is higher than the threshold value written in the Trscv EEPROM <Help> Alarm indic…
1.3.6.1.4.1.20044.80.2.3.1.184.1.6Columnpm10010ulhAlmLineLaserTempLowAlarmPortnread-onlycurrentLine Trscv Tx Laser Temp Low Alarm :This OID indicates that the Trscv Tx Laser Temperature is lower than the threshold value written in the Trscv EEPROM <Help>…
1.3.6.1.4.1.20044.80.2.3.1.184.1.7Columnpm10010ulhAlmLineLaserTempLowWarningPortnread-onlycurrentLine Trscv Tx Laser Temp Low Warning :This OID indicates that the Trscv Tx Laser Temperature is lower than the threshold value written in the Trscv EEPROM <Hel…
1.3.6.1.4.1.20044.80.2.3.1.184.1.8Columnpm10010ulhAlmLineLaserTempHighWarningPortnread-onlycurrentLine Trscv Tx Laser Temp High Warning :This OID indicates that the Trscv Tx Laser Temperature is higher than the threshold value written in the Trscv EEPROM <H…
1.3.6.1.4.1.20044.80.2.3.1.184.1.9Columnpm10010ulhAlmLineLaserTempHighAlarmPortnread-onlycurrentLine Trscv Tx Laser Temp High Alarm :This OID indicates that the Trscv Tx Laser Temperature is higher than the threshold value written in the Trscv EEPROM <Hel…
1.3.6.1.4.1.20044.80.2.3.1.184.1.10Columnpm10010ulhAlmLineTxPowerLowAlarmPortnread-onlycurrentLine Trscv Tx Power Low Alarm :This OID indicates that the Trscv output power is lower than the threshold value written in the Trscv EEPROM <Help> Alarm indica…
1.3.6.1.4.1.20044.80.2.3.1.184.1.11Columnpm10010ulhAlmLineTxPowerLowWarningPortnread-onlycurrentLine Trscv Tx Power Low Warning :This OID indicates that the Trscv output power is lower than the threshold value written in the Trscv EEPROM <Help> Warning in…
1.3.6.1.4.1.20044.80.2.3.1.184.1.12Columnpm10010ulhAlmLineTxPowerHighWarningPortnread-onlycurrentLine Trscv Tx Power High Warning :This OID indicates that the Trscv output power is higher than the threshold value written in the Trscv EEPROM <Help> Warning …
1.3.6.1.4.1.20044.80.2.3.1.184.1.13Columnpm10010ulhAlmLineTxPowerHighAlarmPortnread-onlycurrentLine Trscv Tx Power High Alarm :This OID indicates that the Trscv output power is higher than the threshold value written in the Trscv EEPROM <Help> Alarm indi…
1.3.6.1.4.1.20044.80.2.3.1.184.1.14Columnpm10010ulhAlmLineBiasLowAlarmPortnread-onlycurrentLine Trscv Tx Bias Low Alarm :This OID indicates that the Trscv laser bias current is lower than the threshold value written in the Trscv EEPROM <Help> Alarm i…
1.3.6.1.4.1.20044.80.2.3.1.184.1.15Columnpm10010ulhAlmLineBiasLowWarningPortnread-onlycurrentLine Trscv Tx Bias Low Warning :This OID indicates that the Trscv laser bias current is lower than the threshold value written in the Trscv EEPROM <Help> Warni…
1.3.6.1.4.1.20044.80.2.3.1.184.1.16Columnpm10010ulhAlmLineBiasHighWarningPortnread-onlycurrentLine Trscv Tx Bias High Warning :This OID indicates that the Trscv laser bias current is higher than the threshold value written in the Trscv EEPROM <Help> War…
1.3.6.1.4.1.20044.80.2.3.1.184.1.17Columnpm10010ulhAlmLineBiasHighAlarmPortnread-onlycurrentLine Trscv Tx Bias High Alarm :This OID indicates that the Trscv laser bias current is higher than the threshold value written in the Trscv EEPROM <Help> Alarm…
1.3.6.1.4.1.20044.80.2.3.1.188Tablepm10010ulhAlmlineNetworkLaneAlarmWarning2Tablenot-accessiblecurrentList of pm10010ulhAlmlineNetworkLaneAlarmWarning2 Article
1.3.6.1.4.1.20044.80.2.3.1.188.1Rowpm10010ulhAlmlineNetworkLaneAlarmWarning2Entrynot-accessiblecurrentRow definition for the pm10010ulhAlmlineNetworkLaneAlarmWarning2 table
1.3.6.1.4.1.20044.80.2.3.1.188.1.1Columnpm10010ulhAlmlineNetworkLaneAlarmWarning2Indexread-onlycurrentIndex definition for the pm10010ulhAlmlineNetworkLaneAlarmWarning2 table
1.3.6.1.4.1.20044.80.2.3.1.188.1.2Columnpm10010ulhAlmTxModulatorBiasLowAlarmPortnread-onlycurrentLine Trscv Tx Modulator Bias Low Alarm :This OID indicates that the Trscv Tx modulator bias current is lower than the threshold value written in the Trscv EEPR…
1.3.6.1.4.1.20044.80.2.3.1.188.1.3Columnpm10010ulhAlmTxModulatorBiasLowWarningPortnread-onlycurrentLine Trscv Tx Modulator Bias Low Warning :This OID indicates that the Trscv Tx modulator bias current is lower than the threshold value written in the Trscv EE…
1.3.6.1.4.1.20044.80.2.3.1.188.1.4Columnpm10010ulhAlmTxModulatorBiasHighWarningPortnread-onlycurrentLine Trscv Tx Modulator Bias High Warning :This OID indicates that the Trscv Tx modulator bias current is higher than the threshold value written in the Trscv …
1.3.6.1.4.1.20044.80.2.3.1.188.1.5Columnpm10010ulhAlmTxModulatorBiasHighAlarmPortnread-onlycurrentLine Trscv Tx Modulator Bias High Alarm :This OID indicates that the Trscv Tx modulator bias current is higher than the threshold value written in the Trscv EE…
1.3.6.1.4.1.20044.80.2.3.1.188.1.6Columnpm10010ulhAlmRxLaserTempLowAlarmPortnread-onlycurrentLine Trscv Rx Laser Temp Low Alarm :This OID indicates that the Trscv Rx Laser Temperature is lower than the threshold value written in the Trscv EEPROM <Help>…
1.3.6.1.4.1.20044.80.2.3.1.188.1.7Columnpm10010ulhAlmRxLaserTempLowWarningPortnread-onlycurrentLine Trscv Rx Laser Temp Low Warning :This OID indicates that the Trscv Rx Laser Temperature is lower than the threshold value written in the Trscv EEPROM <Hel…
1.3.6.1.4.1.20044.80.2.3.1.188.1.8Columnpm10010ulhAlmRxLaserTempHighWarningPortnread-onlycurrentLine Trscv Rx Laser Temp High Warning :This OID indicates that the Trscv Rx Laser Temperature is higher than the threshold value written in the Trscv EEPROM <H…
1.3.6.1.4.1.20044.80.2.3.1.188.1.9Columnpm10010ulhAlmRxLaserTempHighAlarmPortnread-onlycurrentLine Trscv Rx Laser Temp High Alarm :This OID indicates that the Trscv Rx Laser Temperature is higher than the threshold value written in the Trscv EEPROM <Hel…
1.3.6.1.4.1.20044.80.2.3.1.188.1.10Columnpm10010ulhAlmRxLaserOutputLowAlarmPortnread-onlycurrentLine Trscv Rx Output Power Low Alarm :This OID indicates that the Trscv Rx output power is lower than the threshold value written in the Trscv EEPROM <Help> Al…
1.3.6.1.4.1.20044.80.2.3.1.188.1.11Columnpm10010ulhAlmRxLaserOutputLowWarningPortnread-onlycurrentLine Trscv Rx Output Power Low Warning :This OID indicates that the Trscv Rx output power is lower than the threshold value written in the Trscv EEPROM <Help> …
1.3.6.1.4.1.20044.80.2.3.1.188.1.12Columnpm10010ulhAlmRxLaserOutputHighWarningPortnread-onlycurrentLine Trscv Rx Output Power High Warning :This OID indicates that the Trscv Rx output power is higher than the threshold value written in the Trscv EEPROM <Help…
1.3.6.1.4.1.20044.80.2.3.1.188.1.13Columnpm10010ulhAlmRxLaserOutputHighAlarmPortnread-onlycurrentLine Trscv Rx Output Power High Alarm :This OID indicates that the Trscv Rx output power is higher than the threshold value written in the Trscv EEPROM <Help> …
1.3.6.1.4.1.20044.80.2.3.1.188.1.14Columnpm10010ulhAlmRxLaserBiasLowAlarmPortnread-onlycurrentLine Trscv Rx Bias Low Alarm :This OID indicates that the Trscv Rx laser bias current is lower than the threshold value written in the Trscv EEPROM <Help> Alar…
1.3.6.1.4.1.20044.80.2.3.1.188.1.15Columnpm10010ulhAlmRxLaserBiasLowWarningPortnread-onlycurrentLine Trscv Rx Bias Low Warning :This OID indicates that the Trscv Rx laser bias current is lower than the threshold value written in the Trscv EEPROM <Help> Wa…
1.3.6.1.4.1.20044.80.2.3.1.188.1.16Columnpm10010ulhAlmRxLaserBiasHighWarningPortnread-onlycurrentLine Trscv Rx Bias High Warning :This OID indicates that the Trscv Rx laser bias current is higher than the threshold value written in the Trscv EEPROM <Help> …
1.3.6.1.4.1.20044.80.2.3.1.188.1.17Columnpm10010ulhAlmRxLaserBiasHighAlarmPortnread-onlycurrentLine Trscv Rx Bias High Alarm :This OID indicates that the Trscv Rx laser bias current is higher than the threshold value written in the Trscv EEPROM <Help> Al…
1.3.6.1.4.1.20044.80.2.3.2Nodepm10010ulhAlmLineUrg
1.3.6.1.4.1.20044.80.2.3.2.192Tablepm10010ulhAlmlineNetworkLaneFaultTablenot-accessiblecurrentList of pm10010ulhAlmlineNetworkLaneFault Article
1.3.6.1.4.1.20044.80.2.3.2.192.1Rowpm10010ulhAlmlineNetworkLaneFaultEntrynot-accessiblecurrentRow definition for the pm10010ulhAlmlineNetworkLaneFault table
1.3.6.1.4.1.20044.80.2.3.2.192.1.1Columnpm10010ulhAlmlineNetworkLaneFaultIndexread-onlycurrentIndex definition for the pm10010ulhAlmlineNetworkLaneFault table
1.3.6.1.4.1.20044.80.2.3.2.192.1.3Columnpm10010ulhAlmLineLaneRxTecFaultPortnread-onlycurrentLine Network Lane Rx TEC Fault :This OID indicates a Rx TEC Fault on the Line Trscv Network Lane <Help> Alarm indicating a Rx TEC Fault on the Line Trscv Netwo…
1.3.6.1.4.1.20044.80.2.3.2.192.1.4Columnpm10010ulhAlmLineLaneRxFifoErrorPortnread-onlycurrentLine Network Lane Rx FIFO Error :This OID indicates a Rx FIFO Error on the Line Trscv Network Lane <Help> Alarm indicating a Rx FIFO Error on the Line Trscv Ne…
1.3.6.1.4.1.20044.80.2.3.2.192.1.5Columnpm10010ulhAlmLineLaneRxLolPortnread-onlycurrentLine Network Lane Rx Loss Of Lock :This OID indicates a Rx Loss of Lock on the Line Trscv Network Lane <Help> Alarm indicating a Rx Loss of Lock on the Line Tr…
1.3.6.1.4.1.20044.80.2.3.2.192.1.6Columnpm10010ulhAlmLineLaneRxLosPortnread-onlycurrentLine Network Lane Rx Loss Of Signal :This OID indicates a Rx Loss of Signal on the Line Trscv Network Lane <Help> Alarm indicating a Rx Loss of Signal on the L…
1.3.6.1.4.1.20044.80.2.3.2.192.1.8Columnpm10010ulhAlmLineLaneTxLolPortnread-onlycurrentLine Network Lane Tx Loss Of Lock :This OID indicates a Tx Loss of Lock on the Line Trscv Network Lane <Help> Alarm indicating a Tx Loss of Lock on the Line Tr…
1.3.6.1.4.1.20044.80.2.3.2.192.1.9Columnpm10010ulhAlmLineLaneTxLosfPortnread-onlycurrentLine Network Lane Tx Loss Of Signal Functionality :This OID indicates a Tx Loss of Signal Functionality on the Line Trscv Network Lane <Help> Alarm indicating …
1.3.6.1.4.1.20044.80.2.3.2.192.1.15Columnpm10010ulhAlmLineLaneApdPowerSupplyPortnread-onlycurrentLine Network Lane APD Power Supply :This OID indicates an APD Power supply failure on the Line Trscv Network Lane <Help> Alarm indicating an APD Power supply f…
1.3.6.1.4.1.20044.80.2.3.2.192.1.16Columnpm10010ulhAlmLineLaneWavelengthUnlockedPortnread-onlycurrentLine Network Lane Wavelength Unlock :This OID indicates a Wavelength unlock on the Line Trscv Network Lane <Help> Alarm indicating a Wavelength unlock on the L…
1.3.6.1.4.1.20044.80.2.3.2.192.1.17Columnpm10010ulhAlmLineLaneTecFaultPortnread-onlycurrentLine Network Lane TEC Fault :This OID indicates a Tx TEC Fault on the Line Trscv Network Lane <Help> Alarm indicating a Tx TEC Fault on the Line Trscv Network …
1.3.6.1.4.1.20044.80.2.3.2.196Tablepm10010ulhAlmlineHostLaneFaultTablenot-accessiblecurrentList of pm10010ulhAlmlineHostLaneFault Article
1.3.6.1.4.1.20044.80.2.3.2.196.1Rowpm10010ulhAlmlineHostLaneFaultEntrynot-accessiblecurrentRow definition for the pm10010ulhAlmlineHostLaneFault table
1.3.6.1.4.1.20044.80.2.3.2.196.1.1Columnpm10010ulhAlmlineHostLaneFaultIndexread-onlycurrentIndex definition for the pm10010ulhAlmlineHostLaneFault table
1.3.6.1.4.1.20044.80.2.3.2.196.1.2Columnpm10010ulhAlmLineInputLossOfSignalPortnread-onlycurrentLine Input Loss Of Signal :This OID indicates a Loss of Signal is detected on the Line Trscv <Help> Alarm indicating a Loss of Signal is detected on the Line T…
1.3.6.1.4.1.20044.80.2.3.2.196.1.3Columnpm10010ulhAlmLineLossOfFramePortnread-onlycurrentLine Loss Of Frame :This OID indicates the module is not aligned with the incoming Line signal <Help> Alarm indicating the module is not aligned with the incom…
1.3.6.1.4.1.20044.80.2.3.2.196.1.4Columnpm10010ulhAlmLineSmBdiInsertedPortnread-onlycurrentLine SM BDI Inserted :This OID indicates a SM Backward Defect Indication is inserted on the outgoing Line signal <Help> Status indicating a SM Backward Defect …
1.3.6.1.4.1.20044.80.2.3.2.196.1.5Columnpm10010ulhAlmLineSmBdiDetectedPortnread-onlycurrentLine SM BDI Detected :This OID indicates a SM Backward Defect Indication is detected on the incoming Line signal <Help> Alarm indicating a SM Backward Defect I…
1.3.6.1.4.1.20044.80.2.3.2.196.1.6Columnpm10010ulhAlmLineSmIaeInsertedPortnread-onlycurrentLine SM IAE Inserted :This OID indicates a SM Incoming Alignment Error is inserted on the outgoing Line signal <Help> Status indicating a SM Incoming Alignment…
1.3.6.1.4.1.20044.80.2.3.2.196.1.7Columnpm10010ulhAlmLineSmIaeDetectedPortnread-onlycurrentLine SM IAE Detected :This OID indicates a SM Incoming Alignment Error is detected on the incoming Line signal <Help> Alarm indicating a SM Incoming Alignment …
1.3.6.1.4.1.20044.80.2.3.2.196.1.10Columnpm10010ulhAlmLineTxHostLolPortnread-onlycurrentLine Host Lane Tx Loss Of Lock :This OID indicates a Tx Loss of Lock on the Line Trscv Host Lane <Help> Alarm indicating a Tx Loss of Lock on the Line Trscv Ho…
1.3.6.1.4.1.20044.80.2.3.2.196.1.11Columnpm10010ulhAlmLineLaneTxFifoErrorPortnread-onlycurrentLine Host Lane Tx FIFO Error :This OID indicates a Tx FIFO Error on the Line Trscv Host Lane <Help> Alarm indicating a Tx FIFO Error on the Line Trscv Host Lan…
1.3.6.1.4.1.20044.80.2.3.2.200Tablepm10010ulhAlmlineNetworkLaneRxOtnTablenot-accessiblecurrentList of pm10010ulhAlmlineNetworkLaneRxOtn Article
1.3.6.1.4.1.20044.80.2.3.2.200.1Rowpm10010ulhAlmlineNetworkLaneRxOtnEntrynot-accessiblecurrentRow definition for the pm10010ulhAlmlineNetworkLaneRxOtn table
1.3.6.1.4.1.20044.80.2.3.2.200.1.1Columnpm10010ulhAlmlineNetworkLaneRxOtnIndexread-onlycurrentIndex definition for the pm10010ulhAlmlineNetworkLaneRxOtn table
1.3.6.1.4.1.20044.80.2.3.2.200.1.10Columnpm10010ulhAlmLineRxOtnOduAisPortnread-onlycurrentLine Network Rx ODU AIS :This OID indicates an ODU This OID Indication Signal is detected on the Rx Network interface of the Line Trscv <Help> Alarm indicating…
1.3.6.1.4.1.20044.80.2.3.2.200.1.11Columnpm10010ulhAlmLineRxOtnOtuAisPortnread-onlycurrentLine Network Rx OTU AIS :This OID indicates an OTU This OID Indication Signal is detected on the Rx Network interface of the Line Trscv <Help> Alarm indicating…
1.3.6.1.4.1.20044.80.2.3.2.200.1.12Columnpm10010ulhAlmLineRxSmBdiPortnread-onlycurrentLine Network Rx SM BDI :This OID indicates an SM Backward Defect Indication is detected on the Rx Network interface of the Line Trscv <Help> Alarm indicating a…
1.3.6.1.4.1.20044.80.2.3.2.200.1.13Columnpm10010ulhAlmLineRxOtnIaePortnread-onlycurrentLine Network Rx IAE :This OID indicates an Incoming Alignment Error is detected on the Rx Network interface of the Line Trscv <Help> Alarm indicating an Incomi…
1.3.6.1.4.1.20044.80.2.3.2.200.1.14Columnpm10010ulhAlmLineRxOtnOomPortnread-onlycurrentLine Network Rx OOM :This OID indicates an Out of Multiframe is detected on the Rx Network interface of the Line Trscv <Help> Alarm indicating an Out of Multif…
1.3.6.1.4.1.20044.80.2.3.2.200.1.15Columnpm10010ulhAlmLineRxOtnLomPortnread-onlycurrentLine Network Rx LOM :This OID indicates a Loss of Multiframe is detected on the Rx Network interface of the Line Trscv <Help> Alarm indicating a Loss of Multif…
1.3.6.1.4.1.20044.80.2.3.2.200.1.16Columnpm10010ulhAlmLineRxOtnOofPortnread-onlycurrentLine Network Rx OOF :This OID indicates an Out of Frame is detected on the Rx Network interface of the Line Trscv <Help> Alarm indicating an Out of Frame is de…
1.3.6.1.4.1.20044.80.2.3.2.200.1.17Columnpm10010ulhAlmLineRxOtnLofPortnread-onlycurrentLine Network Rx LOF :This OID indicates a Loss of Frame is detected on the Rx Network interface of the Line Trscv <Help> Alarm indicating a Loss of Frame is de…
1.3.6.1.4.1.20044.80.2.3.2.204Tablepm10010ulhAlmlineHostLaneTxOtnTablenot-accessiblecurrentList of pm10010ulhAlmlineHostLaneTxOtn Article
1.3.6.1.4.1.20044.80.2.3.2.204.1Rowpm10010ulhAlmlineHostLaneTxOtnEntrynot-accessiblecurrentRow definition for the pm10010ulhAlmlineHostLaneTxOtn table
1.3.6.1.4.1.20044.80.2.3.2.204.1.1Columnpm10010ulhAlmlineHostLaneTxOtnIndexread-onlycurrentIndex definition for the pm10010ulhAlmlineHostLaneTxOtn table
1.3.6.1.4.1.20044.80.2.3.2.204.1.10Columnpm10010ulhAlmLineTxOtnOduAisPortnread-onlycurrentLine Host Tx ODU AIS :This OID indicates an ODU This OID Indication Signal is detected on the Tx Host interface of the Line Trscv <Help> Alarm indicating an OD…
1.3.6.1.4.1.20044.80.2.3.2.204.1.11Columnpm10010ulhAlmLineTxOtnOtuAisPortnread-onlycurrentLine Host Tx OTU AIS :This OID indicates an OTU This OID Indication Signal is detected on the Tx Host interface of the Line Trscv <Help> Alarm indicating an OT…
1.3.6.1.4.1.20044.80.2.3.2.204.1.12Columnpm10010ulhAlmLineTxSmBdiPortnread-onlycurrentLine Host Tx SM BDI :This OID indicates an SM Backward Defect Indication is detected on the Tx Host interface of the Line Trscv <Help> Alarm indicating an SM B…
1.3.6.1.4.1.20044.80.2.3.2.204.1.13Columnpm10010ulhAlmLineTxOtnIaePortnread-onlycurrentLine Host Tx IAE :This OID indicates an Incoming Alignment Error is detected on the Tx Host interface of the Line Trscv <Help> Alarm indicating an Incoming Ali…
1.3.6.1.4.1.20044.80.2.3.2.204.1.14Columnpm10010ulhAlmLineTxOtnOomPortnread-onlycurrentLine Host Tx OOM :This OID indicates an Out of Multiframe is detected on the Tx Host interface of the Line Trscv <Help> Alarm indicating an Out of Multiframe i…
1.3.6.1.4.1.20044.80.2.3.2.204.1.15Columnpm10010ulhAlmLineTxOtnLomPortnread-onlycurrentLine Host Tx LOM :This OID indicates a Loss of Multiframe is detected on the Tx Host interface of the Line Trscv <Help> Alarm indicating a Loss of Multiframe i…
1.3.6.1.4.1.20044.80.2.3.2.204.1.16Columnpm10010ulhAlmLineTxOtnOofPortnread-onlycurrentLine Host Tx OOF :This OID indicates an Out of Frame is detected on the Tx Host interface of the Line Trscv <Help> Alarm indicating an Out of Frame is detected…
1.3.6.1.4.1.20044.80.2.3.2.204.1.17Columnpm10010ulhAlmLineTxOtnLofPortnread-onlycurrentLine Host Tx LOF :This OID indicates a Loss of Frame is detected on the Tx Host interface of the Line Trscv <Help> Alarm indicating a Loss of Frame is detected…
1.3.6.1.4.1.20044.80.2.3.3Nodepm10010ulhAlmLineCrit
1.3.6.1.4.1.20044.80.2.3.3.40Tablepm10010ulhAlmsynthAlmLineTablenot-accessiblecurrentList of pm10010ulhAlmsynthAlmLine Article
1.3.6.1.4.1.20044.80.2.3.3.40.1Rowpm10010ulhAlmsynthAlmLineEntrynot-accessiblecurrentRow definition for the pm10010ulhAlmsynthAlmLine table
1.3.6.1.4.1.20044.80.2.3.3.40.1.1Columnpm10010ulhAlmsynthAlmLineIndexread-onlycurrentIndex definition for the pm10010ulhAlmsynthAlmLine table
1.3.6.1.4.1.20044.80.2.3.3.40.1.2Columnpm10010ulhAlmXfpAbsentPortnread-onlycurrentLine Optical Module Absent :This OID indicates that the line optical interface is not present. <Help> This alarm indicates if the line transceiver is not plugg…
1.3.6.1.4.1.20044.80.2.3.3.40.1.3Columnpm10010ulhAlmXfpInitNotComplPortnread-onlycurrentLine Optical Module Ready :This OID indicates that the optical interface is not operational. <Help> This status indicates if the line transceiver has been corr…
1.3.6.1.4.1.20044.80.2.3.3.40.1.5Columnpm10010ulhAlmLineHwFailPortnread-onlycurrentLine Port HW Failure :This OID indicates a failure on line port, most probably caused by a HW issue <Help> This alarm indicates a failure on line port, most pr…
1.3.6.1.4.1.20044.80.2.3.3.40.1.6Columnpm10010ulhAlmXfpTxOffPortnread-onlycurrentLine Trscv Laser Shutdown :This OID indicates the Line transceiver laser is shutdown <Help> This status indicates if the Line transceiver laser is shutdown <Co…
1.3.6.1.4.1.20044.80.2.3.3.40.1.7Columnpm10010ulhAlmLineLocalOosPortnread-onlycurrentLine Port In Service :This OID indicates that the Line port is In Service (1) of Out or Service (2) <Help> This status indicates if the line port is in service…
1.3.6.1.4.1.20044.80.2.3.3.40.1.9Columnpm10010ulhAlmUpRdiInsPortnread-onlycurrentMS-RDI/L-RDI Inserted On Line :This OID indicates an upstream MS-RDI/L-RDI has been inserted in the outgoing 10 Gb/s SDH/SONET signal. <Help> This status indic…
1.3.6.1.4.1.20044.80.2.3.3.40.1.10Columnpm10010ulhAlmLineDdmWarningPortnread-onlycurrentWarning On Line Optical Module DDM :This OID indicates a warning is present coming out of Line transceiver DDM <Help> This alarm indicates if a DDM Warning has…
1.3.6.1.4.1.20044.80.2.3.3.40.1.11Columnpm10010ulhAlmLineDdmAlmPortnread-onlycurrentAlarm On Line Optical Module DDM :This OID indicates an alarm is present coming out of Line transceiver DDM <Help> This alarm indicates if a DDM Alarm has been…
1.3.6.1.4.1.20044.80.2.3.3.40.1.13Columnpm10010ulhAlmLineFailPortnread-onlycurrentLine Port Failure :This OID indicates a failure on the line port <Help> This alarm indicates a failure on the line port <Condtype> LINE_FAIL <Probcause> equipm…
1.3.6.1.4.1.20044.80.2.3.3.40.1.17Columnpm10010ulhAlmLineActivePortnread-onlycurrentLine Active :This OID indicates whether the line is active or standby. <Help> This status indicates whether the line is active or standby. <Condtype> LINE_ACTI…
1.3.6.1.4.1.20044.80.3Nodepm10010ulhmeasures
1.3.6.1.4.1.20044.80.3.1Nodepm10010ulhMesrOther
1.3.6.1.4.1.20044.80.3.1.0Scalarpm10010ulhMesrsynth0read-onlydeprecatedNot Used :
1.3.6.1.4.1.20044.80.3.1.1Scalarpm10010ulhMesrsynth1read-onlydeprecatedNot Used :
1.3.6.1.4.1.20044.80.3.1.7Scalarpm10010ulhMesrpmIntervalNumberread-onlycurrentPM Interval Counter :
1.3.6.1.4.1.20044.80.3.1.196Scalarpm10010ulhMesrlineNetTxLaserOutputPwrAverageread-onlycurrentAverage Line Trscv Tx Power :This OID gives the average Tx Laser transmit power value among the network lanes of the Line Transceiver, read in the DDM (Digital…
1.3.6.1.4.1.20044.80.3.1.197Scalarpm10010ulhMesrlineNetTxLaserTempAverageread-onlycurrentAverage Line Trscv Tx Laser Temperature :This OID gives the average Tx Laser Temperature value among the network lanes of the Line Transceiver, read from the D…
1.3.6.1.4.1.20044.80.3.1.198Scalarpm10010ulhMesrlineNetTxBiasCurrentAverageread-onlycurrentAverage Line Trscv Tx Laser Bias :This OID gives the average Tx Laser Bias value among the network lanes of the Line Transceiver, read from the DDM (Digital Di…
1.3.6.1.4.1.20044.80.3.1.199Scalarpm10010ulhMesrlineNetRxInputPwrAverageread-onlycurrentAverage Line Trscv Rx Power :This OID gives the average Receive power value among the network lanes of the Line Transceiver, read in the DDM (Digital Diagnosti…
1.3.6.1.4.1.20044.80.3.1.200Scalarpm10010ulhMesrlineResidualChromaticDispAverageread-onlycurrentAverage Residual Chromatic Dispersion :This OID gives the average Residual Chromatic Dispersion on the Line interface since the last measure reset (Dispersion …
1.3.6.1.4.1.20044.80.3.1.201Scalarpm10010ulhMesrlineDiffGroupDelayAverageread-onlycurrentAverage Differential Group Delay :This OID gives the average Group Delay on the Line interface since the last measure reset (Delay = AV_S16) (Unit = ps)<Help> …
1.3.6.1.4.1.20044.80.3.1.202Scalarpm10010ulhMesrlineQFactorAverageread-onlycurrentAverage Q Factor :This OID gives the average Q Factor on the Line interface since the last measure reset (Q Factor = AV_U16) (Unit = dB) <Help> This measure gi…
1.3.6.1.4.1.20044.80.3.1.203Scalarpm10010ulhMesrlineCarrierFreqOffsetAverageread-onlycurrentAverage Carrier Frequency Offset :This OID gives the average Carrier Frequency Offset on the Line interface since the last measure reset (Offset = AV_S16) (Uni…
1.3.6.1.4.1.20044.80.3.1.204Scalarpm10010ulhMesrlineOsnrAverageread-onlycurrentAverage OSNR :This OID gives the average OSNR on the Line interface since the last measure reset (OSNR = AV_S16/10) (Unit = dB)<Help> This measure gives the av…
1.3.6.1.4.1.20044.80.3.1.208Scalarpm10010ulhMesrclientNetTxTempMinread-onlycurrentMin Client Trscv Laser Temperature :This OID gives the minimum Laser temperature value among the network lanes of the Client Transceiver, read from the DDM (Di…
1.3.6.1.4.1.20044.80.3.1.209Scalarpm10010ulhMesrclientNetTxBiasMinread-onlycurrentMin Client Trscv Laser Bias :This OID gives the minimum Laser bias value among the network lanes of the Client Transceiver, read from the DDM (Digital Diagnost…
1.3.6.1.4.1.20044.80.3.1.210Scalarpm10010ulhMesrclientNetTxPwrMinread-onlycurrentMin Client Trscv Tx Power :This OID gives the minimum transmit power value among the network lanes of the Client Transceiver, read from the DDM (Digital Diagno…
1.3.6.1.4.1.20044.80.3.1.211Scalarpm10010ulhMesrclientNetRxPwrMinread-onlycurrentMin Client Trscv Rx Power :This OID gives the minimum receive power value among the network lanes of the Client Transceiver, read in the DDM (Digital Diagnosti…
1.3.6.1.4.1.20044.80.3.1.212Scalarpm10010ulhMesrlineNetTxLaserOutputPwrMinread-onlycurrentMin Line Trscv Tx Power :This OID gives the minimum Tx Laser transmit power value among the network lanes of the Line Transceiver, read in the DDM (Digital Dia…
1.3.6.1.4.1.20044.80.3.1.213Scalarpm10010ulhMesrlineNetTxLaserTempMinread-onlycurrentMin Line Trscv Tx Laser Temperature :This OID gives the minimum Tx Laser Temperature value among the network lanes of the Line Transceiver, read from the DDM (…
1.3.6.1.4.1.20044.80.3.1.214Scalarpm10010ulhMesrlineNetTxBiasCurrentMinread-onlycurrentMin Line Trscv Tx Laser Bias :This OID gives the minimum Tx Laser Bias value among the network lanes of the Line Transceiver, read from the DDM (Digital Diagno…
1.3.6.1.4.1.20044.80.3.1.215Scalarpm10010ulhMesrlineNetRxInputPwrMinread-onlycurrentMin Line Trscv Rx Power :This OID gives the minimum Receive power value among the network lanes of the Line Transceiver, read in the DDM (Digital Diagnostic Mo…
1.3.6.1.4.1.20044.80.3.1.216Scalarpm10010ulhMesrlineResidualChromaticDispMinread-onlycurrentMin Residual Chromatic Dispersion :This OID gives the minimum Residual Chromatic Dispersion on the Line interface since the last measure reset (Dispersion = AV…
1.3.6.1.4.1.20044.80.3.1.217Scalarpm10010ulhMesrlineDiffGroupDelayMinread-onlycurrentMin Differential Group Delay :This OID gives the minimum Differential Group Delay on the Line interface since the last measure reset (Delay = AV_S16) (Unit = p…
1.3.6.1.4.1.20044.80.3.1.218Scalarpm10010ulhMesrlineQFactorMinread-onlycurrentMin Q Factor :This OID gives the minimum Q Factor on the Line interface since the last measure reset (Q Factor = AV_U16) (Unit = dB)<Help> This measure gives t…
1.3.6.1.4.1.20044.80.3.1.219Scalarpm10010ulhMesrlineCarrierFreqOffsetMinread-onlycurrentMin Carrier Frequency Offset :This OID gives the minimum Carrier Frequency Offset on the Line interface since the last measure reset (Offset = AV_S16) (Unit = …
1.3.6.1.4.1.20044.80.3.1.220Scalarpm10010ulhMesrlineOsnrMinread-onlycurrentMin OSNR :This OID gives the minimum OSNR on the Line interface since the last measure reset (OSNR = AV_S16/10) (Unit = dB)<Help> This measure gives the minimu…
1.3.6.1.4.1.20044.80.3.1.224Scalarpm10010ulhMesrclientNetTxTempMaxread-onlycurrentMax Client Trscv Laser Temperature :This OID gives the maximum Laser temperature value among the network lanes of the Client Transceiver, read from the DDM (Di…
1.3.6.1.4.1.20044.80.3.1.225Scalarpm10010ulhMesrclientNetTxBiasMaxread-onlycurrentMax Client Trscv Laser Bias :This OID gives the maximum Laser bias value among the network lanes of the Client Transceiver, read from the DDM (Digital Diagnost…
1.3.6.1.4.1.20044.80.3.1.226Scalarpm10010ulhMesrclientNetTxPwrMaxread-onlycurrentMax Client Trscv Tx Power :This OID gives the maximum transmit power value among the network lanes of the Client Transceiver, read from the DDM (Digital Diagno…
1.3.6.1.4.1.20044.80.3.1.227Scalarpm10010ulhMesrclientNetRxPwrMaxread-onlycurrentMax Client Trscv Rx Power :This OID gives the maximum receive power value among the network lanes of the Client Transceiver, read in the DDM (Digital Diagnosti…
1.3.6.1.4.1.20044.80.3.1.228Scalarpm10010ulhMesrlineNetTxLaserOutputPwrMaxread-onlycurrentMax Line Trscv Tx Power :This OID gives the maximum Tx Laser transmit power value among the network lanes of the Line Transceiver, read in the DDM (Digital Dia…
1.3.6.1.4.1.20044.80.3.1.229Scalarpm10010ulhMesrlineNetTxLaserTempMaxread-onlycurrentMax Line Trscv Tx Laser Temperature :This OID gives the maximum Tx Laser Temperature value among the network lanes of the Line Transceiver, read from the DDM (…
1.3.6.1.4.1.20044.80.3.1.230Scalarpm10010ulhMesrlineNetTxBiasCurrentMaxread-onlycurrentMax Line Trscv Tx Laser Bias :This OID gives the maximum Tx Laser Bias value among the network lanes of the Line Transceiver, read from the DDM (Digital Diagno…
1.3.6.1.4.1.20044.80.3.1.231Scalarpm10010ulhMesrlineNetRxInputPwrMaxread-onlycurrentMax Line Trscv Rx Power :This OID gives the maximum Receive power value among the network lanes of the Line Transceiver, read in the DDM (Digital Diagnostic Mo…
1.3.6.1.4.1.20044.80.3.1.232Scalarpm10010ulhMesrlineResidualChromaticDispMaxread-onlycurrentMax Residual Chromatic Dispersion :This OID gives the maximum Residual Chromatic Dispersion on the Line interface since the last measure reset (Dispersion = AV…
1.3.6.1.4.1.20044.80.3.1.233Scalarpm10010ulhMesrlineDiffGroupDelayMaxread-onlycurrentMax Differential Group Delay :This OID gives the maximum Differential Group Delay on the Line interface since the last measure reset (Delay = AV_S16) (Unit = p…
1.3.6.1.4.1.20044.80.3.1.234Scalarpm10010ulhMesrlineQFactorMaxread-onlycurrentMax Q Factor :This OID gives the maximum Q Factor on the Line interface since the last measure reset (Q Factor = AV_U16) (Unit = dB)<Help> This measure gives t…
1.3.6.1.4.1.20044.80.3.1.235Scalarpm10010ulhMesrlineCarrierFreqOffsetMaxread-onlycurrentMax Carrier Frequency Offset :This OID gives the maximum Carrier Frequency Offset on the Line interface since the last measure reset (Offset = AV_S16) (Unit = …
1.3.6.1.4.1.20044.80.3.1.236Scalarpm10010ulhMesrlineOsnrMaxread-onlycurrentMax OSNR :This OID gives the maximum OSNR on the Line interface since the last measure reset (OSNR = AV_S16/10) (Unit = dB)<Help> This measure gives the maximu…
1.3.6.1.4.1.20044.80.3.2Nodepm10010ulhMesrClient
1.3.6.1.4.1.20044.80.3.2.8Scalarpm10010ulhMesrclientCfpTempread-onlycurrentClient Trscv Temperature :This OID gives the temperature value of the Client Transceiver, read from the DDM (Digital Diagnostic Monitoring) (Temperature = AV_S…
1.3.6.1.4.1.20044.80.3.2.9Scalarpm10010ulhMesrclientCfp3v3Voltageread-onlycurrentClient Trscv Voltage :This OID gives the 3V3 voltage value of the Client Transceiver, read from the DDM (Digital Diagnostic Monitoring) (Voltage = AV_U16/10000…
1.3.6.1.4.1.20044.80.3.2.10Scalarpm10010ulhMesrclientSoaBiasCurrentread-onlycurrentClient Trscv SOA Bias :This OID gives the SOA bias value of the Client Transceiver, read from the DDM (Digital Diagnostic Monitoring) (Bias = AV_U16/500) (Unit…
1.3.6.1.4.1.20044.80.3.2.16Tablepm10010ulhMesrclientNetTxTempTablenot-accessiblecurrentList of pm10010ulhMesrclientNetTxTemp Article
1.3.6.1.4.1.20044.80.3.2.16.1Rowpm10010ulhMesrclientNetTxTempEntrynot-accessiblecurrentRow definition for the pm10010ulhMesrclientNetTxTemp table
1.3.6.1.4.1.20044.80.3.2.16.1.1Columnpm10010ulhMesrclientNetTxTempIndexread-onlycurrentIndex definition for the pm10010ulhMesrclientNetTxTemp table
1.3.6.1.4.1.20044.80.3.2.16.1.2Columnpm10010ulhMesrclientNetTxTempPortnread-onlycurrentClient Trscv Temperature :This OID gives the Laser temperature value of the Client Transceiver, read from the DDM (Digital Diagnostic Monitoring) (Temperature …
1.3.6.1.4.1.20044.80.3.2.48Tablepm10010ulhMesrclientNetTxBiasTablenot-accessiblecurrentList of pm10010ulhMesrclientNetTxBias Article
1.3.6.1.4.1.20044.80.3.2.48.1Rowpm10010ulhMesrclientNetTxBiasEntrynot-accessiblecurrentRow definition for the pm10010ulhMesrclientNetTxBias table
1.3.6.1.4.1.20044.80.3.2.48.1.1Columnpm10010ulhMesrclientNetTxBiasIndexread-onlycurrentIndex definition for the pm10010ulhMesrclientNetTxBias table
1.3.6.1.4.1.20044.80.3.2.48.1.2Columnpm10010ulhMesrclientNetTxBiasPortnread-onlycurrentClient Trscv Laser Bias :This OID gives the Laser bias value of the Client Transceiver, read from the DDM (Digital Diagnostic Monitoring) (Bias = AV_U16/500) (…
1.3.6.1.4.1.20044.80.3.2.80Tablepm10010ulhMesrclientNetTxPwrTablenot-accessiblecurrentList of pm10010ulhMesrclientNetTxPwr Article
1.3.6.1.4.1.20044.80.3.2.80.1Rowpm10010ulhMesrclientNetTxPwrEntrynot-accessiblecurrentRow definition for the pm10010ulhMesrclientNetTxPwr table
1.3.6.1.4.1.20044.80.3.2.80.1.1Columnpm10010ulhMesrclientNetTxPwrIndexread-onlycurrentIndex definition for the pm10010ulhMesrclientNetTxPwr table
1.3.6.1.4.1.20044.80.3.2.80.1.2Columnpm10010ulhMesrclientNetTxPwrPortnread-onlycurrentClient Trscv Tx Power :This OID gives the transmit power value of the Client Transceiver, read from the DDM (Digital Diagnostic Monitoring) (Power = 10*log(AV_…
1.3.6.1.4.1.20044.80.3.2.112Tablepm10010ulhMesrclientNetRxPwrTablenot-accessiblecurrentList of pm10010ulhMesrclientNetRxPwr Article
1.3.6.1.4.1.20044.80.3.2.112.1Rowpm10010ulhMesrclientNetRxPwrEntrynot-accessiblecurrentRow definition for the pm10010ulhMesrclientNetRxPwr table
1.3.6.1.4.1.20044.80.3.2.112.1.1Columnpm10010ulhMesrclientNetRxPwrIndexread-onlycurrentIndex definition for the pm10010ulhMesrclientNetRxPwr table
1.3.6.1.4.1.20044.80.3.2.112.1.2Columnpm10010ulhMesrclientNetRxPwrPortnread-onlycurrentClient Trscv Rx Power :This OID gives the receive power value of the Client Transceiver, read in the DDM (Digital Diagnostic Monitoring) (Power = 10*log(AV_U16…
1.3.6.1.4.1.20044.80.3.3Nodepm10010ulhMesrLine
1.3.6.1.4.1.20044.80.3.3.12Scalarpm10010ulhMesrlineMsaTempread-onlycurrentLine Trscv Temperature :This OID gives the temperature value of the Line Transceiver, read from the DDM (Digital Diagnostic Monitoring) (Temperature = AV_S16/2…
1.3.6.1.4.1.20044.80.3.3.13Scalarpm10010ulhMesrlineMsa3v3Voltageread-onlycurrentLine Trscv Voltage :This OID gives the 3V3 voltage value of the Line Transceiver, read from the DDM (Digital Diagnostic Monitoring) (Voltage = AV_U16/10000) (U…
1.3.6.1.4.1.20044.80.3.3.14Scalarpm10010ulhMesrlineSoaBiasCurrentread-onlycurrentLine Trscv SOA Bias :This OID gives the SOA bias value of the Line Transceiver,read from the DDM (Digital Diagnostic Monitoring) (Bias = AV_U16/500) (Unit = mA…
1.3.6.1.4.1.20044.80.3.3.144Tablepm10010ulhMesrlineNetTxLaserOutputPwrTablenot-accessiblecurrentList of pm10010ulhMesrlineNetTxLaserOutputPwr Article
1.3.6.1.4.1.20044.80.3.3.144.1Rowpm10010ulhMesrlineNetTxLaserOutputPwrEntrynot-accessiblecurrentRow definition for the pm10010ulhMesrlineNetTxLaserOutputPwr table
1.3.6.1.4.1.20044.80.3.3.144.1.1Columnpm10010ulhMesrlineNetTxLaserOutputPwrIndexread-onlycurrentIndex definition for the pm10010ulhMesrlineNetTxLaserOutputPwr table
1.3.6.1.4.1.20044.80.3.3.144.1.2Columnpm10010ulhMesrlineNetTxLaserOutputPwrPortnread-onlycurrentCurrent Line Trscv Tx Power :This OID gives the Tx Laser transmit power value of the Line Transceiver, read in the DDM (Digital Diagnostic Monitoring) (Power =…
1.3.6.1.4.1.20044.80.3.3.148Tablepm10010ulhMesrlineNetTxLaserTempTablenot-accessiblecurrentList of pm10010ulhMesrlineNetTxLaserTemp Article
1.3.6.1.4.1.20044.80.3.3.148.1Rowpm10010ulhMesrlineNetTxLaserTempEntrynot-accessiblecurrentRow definition for the pm10010ulhMesrlineNetTxLaserTemp table
1.3.6.1.4.1.20044.80.3.3.148.1.1Columnpm10010ulhMesrlineNetTxLaserTempIndexread-onlycurrentIndex definition for the pm10010ulhMesrlineNetTxLaserTemp table
1.3.6.1.4.1.20044.80.3.3.148.1.2Columnpm10010ulhMesrlineNetTxLaserTempPortnread-onlycurrentCurrent Line Trscv Tx Laser Temperature :This OID gives the Tx Laser Temperature value of the Line Transceiver, read from the DDM (Digital Diagnostic Monitorin…
1.3.6.1.4.1.20044.80.3.3.152Tablepm10010ulhMesrlineNetTxBiasCurrentTablenot-accessiblecurrentList of pm10010ulhMesrlineNetTxBiasCurrent Article
1.3.6.1.4.1.20044.80.3.3.152.1Rowpm10010ulhMesrlineNetTxBiasCurrentEntrynot-accessiblecurrentRow definition for the pm10010ulhMesrlineNetTxBiasCurrent table
1.3.6.1.4.1.20044.80.3.3.152.1.1Columnpm10010ulhMesrlineNetTxBiasCurrentIndexread-onlycurrentIndex definition for the pm10010ulhMesrlineNetTxBiasCurrent table
1.3.6.1.4.1.20044.80.3.3.152.1.2Columnpm10010ulhMesrlineNetTxBiasCurrentPortnread-onlycurrentCurrent Line Trscv Tx Laser Bias :This OID gives the Tx Laser Bias value of the Line Transceiver, read from the DDM (Digital Diagnostic Monitoring) (Bias = AV_…
1.3.6.1.4.1.20044.80.3.3.156Tablepm10010ulhMesrlineNetRxInputPwrTablenot-accessiblecurrentList of pm10010ulhMesrlineNetRxInputPwr Article
1.3.6.1.4.1.20044.80.3.3.156.1Rowpm10010ulhMesrlineNetRxInputPwrEntrynot-accessiblecurrentRow definition for the pm10010ulhMesrlineNetRxInputPwr table
1.3.6.1.4.1.20044.80.3.3.156.1.1Columnpm10010ulhMesrlineNetRxInputPwrIndexread-onlycurrentIndex definition for the pm10010ulhMesrlineNetRxInputPwr table
1.3.6.1.4.1.20044.80.3.3.156.1.2Columnpm10010ulhMesrlineNetRxInputPwrPortnread-onlycurrentCurrent Line Trscv Rx Power :This OID gives the Receive power value of the Line Transceiver, read in the DDM (Digital Diagnostic Monitoring) (Power = AV_S16/10…
1.3.6.1.4.1.20044.80.3.3.160Tablepm10010ulhMesrlineResidualChromaticDispTablenot-accessiblecurrentList of pm10010ulhMesrlineResidualChromaticDisp Article
1.3.6.1.4.1.20044.80.3.3.160.1Rowpm10010ulhMesrlineResidualChromaticDispEntrynot-accessiblecurrentRow definition for the pm10010ulhMesrlineResidualChromaticDisp table
1.3.6.1.4.1.20044.80.3.3.160.1.1Columnpm10010ulhMesrlineResidualChromaticDispIndexread-onlycurrentIndex definition for the pm10010ulhMesrlineResidualChromaticDisp table
1.3.6.1.4.1.20044.80.3.3.160.1.2Columnpm10010ulhMesrlineResidualChromaticDispPortnread-onlycurrentCurrent Residual Chromatic Dispersion :This OID gives the current Residual Chromatic Dispersion on the Line interface (Dispersion = AV_S16*(-2)) (Unit = ps/nm)…
1.3.6.1.4.1.20044.80.3.3.164Tablepm10010ulhMesrlineDiffGroupDelayTablenot-accessiblecurrentList of pm10010ulhMesrlineDiffGroupDelay Article
1.3.6.1.4.1.20044.80.3.3.164.1Rowpm10010ulhMesrlineDiffGroupDelayEntrynot-accessiblecurrentRow definition for the pm10010ulhMesrlineDiffGroupDelay table
1.3.6.1.4.1.20044.80.3.3.164.1.1Columnpm10010ulhMesrlineDiffGroupDelayIndexread-onlycurrentIndex definition for the pm10010ulhMesrlineDiffGroupDelay table
1.3.6.1.4.1.20044.80.3.3.164.1.2Columnpm10010ulhMesrlineDiffGroupDelayPortnread-onlycurrentCurrent Differential Group Delay :This OID gives the current Differential Group Delay on the Line interface (Delay = AV_S16) (Unit = ps)<Help> This measure giv…
1.3.6.1.4.1.20044.80.3.3.168Tablepm10010ulhMesrlineQFactorTablenot-accessiblecurrentList of pm10010ulhMesrlineQFactor Article
1.3.6.1.4.1.20044.80.3.3.168.1Rowpm10010ulhMesrlineQFactorEntrynot-accessiblecurrentRow definition for the pm10010ulhMesrlineQFactor table
1.3.6.1.4.1.20044.80.3.3.168.1.1Columnpm10010ulhMesrlineQFactorIndexread-onlycurrentIndex definition for the pm10010ulhMesrlineQFactor table
1.3.6.1.4.1.20044.80.3.3.168.1.2Columnpm10010ulhMesrlineQFactorPortnread-onlycurrentCurrent Q Factor :This OID gives the current Q Factor on the Line interface (Q Factor = AV_U16) (Unit = dB) <Help> This measure gives the current Q Factor on t…
1.3.6.1.4.1.20044.80.3.3.172Tablepm10010ulhMesrlineCarrierFreqOffsetTablenot-accessiblecurrentList of pm10010ulhMesrlineCarrierFreqOffset Article
1.3.6.1.4.1.20044.80.3.3.172.1Rowpm10010ulhMesrlineCarrierFreqOffsetEntrynot-accessiblecurrentRow definition for the pm10010ulhMesrlineCarrierFreqOffset table
1.3.6.1.4.1.20044.80.3.3.172.1.1Columnpm10010ulhMesrlineCarrierFreqOffsetIndexread-onlycurrentIndex definition for the pm10010ulhMesrlineCarrierFreqOffset table
1.3.6.1.4.1.20044.80.3.3.172.1.2Columnpm10010ulhMesrlineCarrierFreqOffsetPortnread-onlycurrentCurrent Carrier Frequency Offset :This OID gives the current Carrier Frequency Offset on the Line interface (Offset = AV_S16) (Unit = MHz)<Help> This measure g…
1.3.6.1.4.1.20044.80.3.3.176Tablepm10010ulhMesrlineOsnrTablenot-accessiblecurrentList of pm10010ulhMesrlineOsnr Article
1.3.6.1.4.1.20044.80.3.3.176.1Rowpm10010ulhMesrlineOsnrEntrynot-accessiblecurrentRow definition for the pm10010ulhMesrlineOsnr table
1.3.6.1.4.1.20044.80.3.3.176.1.1Columnpm10010ulhMesrlineOsnrIndexread-onlycurrentIndex definition for the pm10010ulhMesrlineOsnr table
1.3.6.1.4.1.20044.80.3.3.176.1.2Columnpm10010ulhMesrlineOsnrPortnread-onlycurrentCurrent OSNR :This OID gives the current OSNR on the Line interface (OSNR = AV_S16/10) (Unit = dB)<Help> This measure gives the current OSNR on the Line interf…
1.3.6.1.4.1.20044.80.4Nodepm10010ulhcounters
1.3.6.1.4.1.20044.80.4.1Nodepm10010ulhCntOther
1.3.6.1.4.1.20044.80.4.2Nodepm10010ulhCntClient
1.3.6.1.4.1.20044.80.4.2.112Tablepm10010ulhCntclientInputErrorCounterTablenot-accessiblecurrentList of pm10010ulhCntclientInputErrorCounter Article
1.3.6.1.4.1.20044.80.4.2.112.1Rowpm10010ulhCntclientInputErrorCounterEntrynot-accessiblecurrentRow definition for the pm10010ulhCntclientInputErrorCounter table
1.3.6.1.4.1.20044.80.4.2.112.1.1Columnpm10010ulhCntclientInputErrorCounterIndexread-onlycurrentIndex definition for the pm10010ulhCntclientInputErrorCounter table
1.3.6.1.4.1.20044.80.4.2.112.1.2Columnpm10010ulhCntclientInputErrorCounterValuePortnread-onlycurrentClient Input Errors :This counter is increased each time a 10b/8b running disparity error is detected on the Client input stream <Help> This counter gives the …
1.3.6.1.4.1.20044.80.4.2.112.1.3Columnpm10010ulhCntclientInputErrorCounterErrorPortnread-onlycurrentClient Counter Error :This OID when set indicates the client error counter value is invalid on Port
1.3.6.1.4.1.20044.80.4.2.112.1.4Columnpm10010ulhCntclientInputErrorCounterOverloadPortnread-onlycurrentClient Counter Overload :This OID when set indicates a client input error counter overload on Port
1.3.6.1.4.1.20044.80.4.2.144Tablepm10010ulhCntclientCbipCounterTablenot-accessiblecurrentList of pm10010ulhCntclientCbipCounter Article
1.3.6.1.4.1.20044.80.4.2.144.1Rowpm10010ulhCntclientCbipCounterEntrynot-accessiblecurrentRow definition for the pm10010ulhCntclientCbipCounter table
1.3.6.1.4.1.20044.80.4.2.144.1.1Columnpm10010ulhCntclientCbipCounterIndexread-onlycurrentIndex definition for the pm10010ulhCntclientCbipCounter table
1.3.6.1.4.1.20044.80.4.2.144.1.2Columnpm10010ulhCntclientCbipCounterValuePortnread-onlycurrentClient Output Errors :This counter is incremented each time a CBIP parity error is detected on the Client output stream <Help> This counter gives the number of…
1.3.6.1.4.1.20044.80.4.2.144.1.3Columnpm10010ulhCntclientCbipCounterErrorPortnread-onlycurrentClient Counter Error :This OID when set indicates the CBIP error counter value is invalid on Port
1.3.6.1.4.1.20044.80.4.2.144.1.4Columnpm10010ulhCntclientCbipCounterOverloadPortnread-onlycurrentClient CBIP Counter Overload :This OID when set indicates a CBIP error counter overload on Port
1.3.6.1.4.1.20044.80.4.3Nodepm10010ulhCntLine
1.3.6.1.4.1.20044.80.4.3.192Tablepm10010ulhCntlocalLineSmBip8ErrorCounterTablenot-accessiblecurrentList of pm10010ulhCntlocalLineSmBip8ErrorCounter Article
1.3.6.1.4.1.20044.80.4.3.192.1Rowpm10010ulhCntlocalLineSmBip8ErrorCounterEntrynot-accessiblecurrentRow definition for the pm10010ulhCntlocalLineSmBip8ErrorCounter table
1.3.6.1.4.1.20044.80.4.3.192.1.1Columnpm10010ulhCntlocalLineSmBip8ErrorCounterIndexread-onlycurrentIndex definition for the pm10010ulhCntlocalLineSmBip8ErrorCounter table
1.3.6.1.4.1.20044.80.4.3.192.1.2Columnpm10010ulhCntlocalLineSmBip8ErrorCounterValuePortnread-onlycurrentUncorrected SD FEC Errors :This OID gives the current Bit Error Rate (residual SM-BIP8 error) after FEC <Help> This counter gives the current Bit Error Rate (r…
1.3.6.1.4.1.20044.80.4.3.192.1.3Columnpm10010ulhCntlocalLineSmBip8ErrorCounterErrorPortnread-onlycurrentLine Counter Error :This OID when set indicates the B1 error counter value is invalid on Port
1.3.6.1.4.1.20044.80.4.3.192.1.4Columnpm10010ulhCntlocalLineSmBip8ErrorCounterOverloadPortnread-onlycurrentLine Counter Overload :This OID when set indicates a B1 error counter overload on Port
1.3.6.1.4.1.20044.80.4.3.193Tablepm10010ulhCntlocalLineFecCorrectedErrorsCounterTablenot-accessiblecurrentList of pm10010ulhCntlocalLineFecCorrectedErrorsCounter Article
1.3.6.1.4.1.20044.80.4.3.193.1Rowpm10010ulhCntlocalLineFecCorrectedErrorsCounterEntrynot-accessiblecurrentRow definition for the pm10010ulhCntlocalLineFecCorrectedErrorsCounter table
1.3.6.1.4.1.20044.80.4.3.193.1.1Columnpm10010ulhCntlocalLineFecCorrectedErrorsCounterIndexread-onlycurrentIndex definition for the pm10010ulhCntlocalLineFecCorrectedErrorsCounter table
1.3.6.1.4.1.20044.80.4.3.193.1.2Columnpm10010ulhCntlocalLineFecCorrectedErrorsCounterValuePortnread-onlycurrentLine Input HD FEC Corrected Errors :This OID gives the current Bit Error Rate before the Hard Decision FEC <Help> This counter gives the current Bit Error Rate…
1.3.6.1.4.1.20044.80.4.3.193.1.3Columnpm10010ulhCntlocalLineFecCorrectedErrorsCounterErrorPortnread-onlycurrentFEC Counter Error :This bit when set indicates the FEC corrected errors counter value is invalid on Line
1.3.6.1.4.1.20044.80.4.3.193.1.4Columnpm10010ulhCntlocalLineFecCorrectedErrorsCounterOverloadPortnread-onlycurrentFEC Counter Overload :This bit when set indicates a FEC corrected errors counter overload on Line
1.3.6.1.4.1.20044.80.4.3.194Tablepm10010ulhCntremoteLineSmBip8ErrorCounterTablenot-accessiblecurrentList of pm10010ulhCntremoteLineSmBip8ErrorCounter Article
1.3.6.1.4.1.20044.80.4.3.194.1Rowpm10010ulhCntremoteLineSmBip8ErrorCounterEntrynot-accessiblecurrentRow definition for the pm10010ulhCntremoteLineSmBip8ErrorCounter table
1.3.6.1.4.1.20044.80.4.3.194.1.1Columnpm10010ulhCntremoteLineSmBip8ErrorCounterIndexread-onlycurrentIndex definition for the pm10010ulhCntremoteLineSmBip8ErrorCounter table
1.3.6.1.4.1.20044.80.4.3.194.1.2Columnpm10010ulhCntremoteLineSmBip8ErrorCounterValuePortnread-onlycurrentRemote SM BIP8 :This OID gives the current Bit Error Rate (residual SM-BIP8 error) after FEC on the remote side <Help> This counter gives the current Bit Error…
1.3.6.1.4.1.20044.80.4.3.194.1.3Columnpm10010ulhCntremoteLineSmBip8ErrorCounterErrorPortnread-onlycurrentRemote Counter Error :
1.3.6.1.4.1.20044.80.4.3.194.1.4Columnpm10010ulhCntremoteLineSmBip8ErrorCounterOverloadPortnread-onlycurrentRemote Counter Overload :
1.3.6.1.4.1.20044.80.4.3.195Tablepm10010ulhCntlineDfrmTimCntTablenot-accessiblecurrentList of pm10010ulhCntlineDfrmTimCnt Article
1.3.6.1.4.1.20044.80.4.3.195.1Rowpm10010ulhCntlineDfrmTimCntEntrynot-accessiblecurrentRow definition for the pm10010ulhCntlineDfrmTimCnt table
1.3.6.1.4.1.20044.80.4.3.195.1.1Columnpm10010ulhCntlineDfrmTimCntIndexread-onlycurrentIndex definition for the pm10010ulhCntlineDfrmTimCnt table
1.3.6.1.4.1.20044.80.4.3.195.1.2Columnpm10010ulhCntlineDfrmTimCntValuePortnread-onlycurrentLine Timer Counter :
1.3.6.1.4.1.20044.80.4.3.195.1.3Columnpm10010ulhCntlineDfrmTimCntErrorPortnread-onlycurrentLine Counter Error :This OID when set indicates the deframer timer counter value is invalid on Port
1.3.6.1.4.1.20044.80.4.3.195.1.4Columnpm10010ulhCntlineDfrmTimCntOverloadPortnread-onlycurrentLine Counter Overload :This OID when set indicates a deframer timer counter overload on Port
1.3.6.1.4.1.20044.80.4.3.196Tablepm10010ulhCntlocalLineTrscvPreSdFecErrorCounterTablenot-accessiblecurrentList of pm10010ulhCntlocalLineTrscvPreSdFecErrorCounter Article
1.3.6.1.4.1.20044.80.4.3.196.1Rowpm10010ulhCntlocalLineTrscvPreSdFecErrorCounterEntrynot-accessiblecurrentRow definition for the pm10010ulhCntlocalLineTrscvPreSdFecErrorCounter table
1.3.6.1.4.1.20044.80.4.3.196.1.1Columnpm10010ulhCntlocalLineTrscvPreSdFecErrorCounterIndexread-onlycurrentIndex definition for the pm10010ulhCntlocalLineTrscvPreSdFecErrorCounter table
1.3.6.1.4.1.20044.80.4.3.196.1.2Columnpm10010ulhCntlocalLineTrscvPreSdFecErrorCounterValuePortnread-onlycurrentPre-SD FEC Errors :This OID gives the current Bit Error Rate before the Soft Decision FEC <Help> This counter gives the current Bit Error Rate before the Soft …
1.3.6.1.4.1.20044.80.4.3.196.1.3Columnpm10010ulhCntlocalLineTrscvPreSdFecErrorCounterErrorPortnread-onlycurrentLine Counter Error :This OID when set indicates the deframer timer counter value is invalid on Port
1.3.6.1.4.1.20044.80.4.3.196.1.4Columnpm10010ulhCntlocalLineTrscvPreSdFecErrorCounterOverloadPortnread-onlycurrentLine Counter Overload :This OID when set indicates a deframer timer counter overload on Port
1.3.6.1.4.1.20044.80.4.3.197Tablepm10010ulhCntlocalLineTrscvUncorrectedSdFecErrorCounterTablenot-accessiblecurrentList of pm10010ulhCntlocalLineTrscvUncorrectedSdFecErrorCounter Article
1.3.6.1.4.1.20044.80.4.3.197.1Rowpm10010ulhCntlocalLineTrscvUncorrectedSdFecErrorCounterEntrynot-accessiblecurrentRow definition for the pm10010ulhCntlocalLineTrscvUncorrectedSdFecErrorCounter table
1.3.6.1.4.1.20044.80.4.3.197.1.1Columnpm10010ulhCntlocalLineTrscvUncorrectedSdFecErrorCounterIndexread-onlycurrentIndex definition for the pm10010ulhCntlocalLineTrscvUncorrectedSdFecErrorCounter table
1.3.6.1.4.1.20044.80.4.3.197.1.2Columnpm10010ulhCntlocalLineTrscvUncorrectedSdFecErrorCounterValuePortnread-onlycurrentUncorrected SD FEC Errors :This OID gives the current Bit Error Rate after the Soft Decision FEC (residual) <Help> This counter gives the current Bit Error Rat…
1.3.6.1.4.1.20044.80.4.3.197.1.3Columnpm10010ulhCntlocalLineTrscvUncorrectedSdFecErrorCounterErrorPortnread-onlycurrentLine Counter Error :This OID when set indicates the deframer timer counter value is invalid on Port
1.3.6.1.4.1.20044.80.4.3.197.1.4Columnpm10010ulhCntlocalLineTrscvUncorrectedSdFecErrorCounterOverloadPortnread-onlycurrentLine Counter Overload :This OID when set indicates a deframer timer counter overload on Port
1.3.6.1.4.1.20044.80.4.3.198Tablepm10010ulhCntlocalLineTrscvPreSdFecBitCounterTablenot-accessiblecurrentList of pm10010ulhCntlocalLineTrscvPreSdFecBitCounter Article
1.3.6.1.4.1.20044.80.4.3.198.1Rowpm10010ulhCntlocalLineTrscvPreSdFecBitCounterEntrynot-accessiblecurrentRow definition for the pm10010ulhCntlocalLineTrscvPreSdFecBitCounter table
1.3.6.1.4.1.20044.80.4.3.198.1.1Columnpm10010ulhCntlocalLineTrscvPreSdFecBitCounterIndexread-onlycurrentIndex definition for the pm10010ulhCntlocalLineTrscvPreSdFecBitCounter table
1.3.6.1.4.1.20044.80.4.3.198.1.2Columnpm10010ulhCntlocalLineTrscvPreSdFecBitCounterValuePortnread-onlycurrentPre-SD FEC Bit Counter :This OID gives the current Bit count before the Soft Decision FEC <Help> This counter gives the current Bit Count before the Soft Decis…
1.3.6.1.4.1.20044.80.4.3.198.1.3Columnpm10010ulhCntlocalLineTrscvPreSdFecBitCounterErrorPortnread-onlycurrentLine Counter Error :This OID when set indicates the deframer timer counter value is invalid on Port
1.3.6.1.4.1.20044.80.4.3.198.1.4Columnpm10010ulhCntlocalLineTrscvPreSdFecBitCounterOverloadPortnread-onlycurrentLine Counter Overload :This OID when set indicates a deframer timer counter overload on Port
1.3.6.1.4.1.20044.80.4.3.199Tablepm10010ulhCntlocalLineTrscvUncorrectedSdFecBitCounterTablenot-accessiblecurrentList of pm10010ulhCntlocalLineTrscvUncorrectedSdFecBitCounter Article
1.3.6.1.4.1.20044.80.4.3.199.1Rowpm10010ulhCntlocalLineTrscvUncorrectedSdFecBitCounterEntrynot-accessiblecurrentRow definition for the pm10010ulhCntlocalLineTrscvUncorrectedSdFecBitCounter table
1.3.6.1.4.1.20044.80.4.3.199.1.1Columnpm10010ulhCntlocalLineTrscvUncorrectedSdFecBitCounterIndexread-onlycurrentIndex definition for the pm10010ulhCntlocalLineTrscvUncorrectedSdFecBitCounter table
1.3.6.1.4.1.20044.80.4.3.199.1.2Columnpm10010ulhCntlocalLineTrscvUncorrectedSdFecBitCounterValuePortnread-onlycurrentUncorrected SD FEC Bit Counter :This OID gives the current Bit count after the Soft Decision FEC (residual) <Help> This counter gives the current Bit Count aft…
1.3.6.1.4.1.20044.80.4.3.199.1.3Columnpm10010ulhCntlocalLineTrscvUncorrectedSdFecBitCounterErrorPortnread-onlycurrentLine Counter Error :This OID when set indicates the deframer timer counter value is invalid on Port
1.3.6.1.4.1.20044.80.4.3.199.1.4Columnpm10010ulhCntlocalLineTrscvUncorrectedSdFecBitCounterOverloadPortnread-onlycurrentLine Counter Overload :This OID when set indicates a deframer timer counter overload on Port
1.3.6.1.4.1.20044.80.6Nodepm10010ulhcontrolsWrite
1.3.6.1.4.1.20044.80.6.1Nodepm10010ulhCtrlOther
1.3.6.1.4.1.20044.80.6.1.1Nodepm10010ulhCtrlconfMgnt1
1.3.6.1.4.1.20044.80.6.1.1.1Scalarpm10010ulhCtrlConf1Load1read-writecurrentLoad Configuration Tables Set Nb 1 :When set this OID enables loading from flash configuration1 into the PM.
1.3.6.1.4.1.20044.80.6.1.1.2Scalarpm10010ulhCtrlConf2Load1read-writecurrentLoad Configuration Tables Set Nb 2 :When set this OID enables loading from flash configuration2 into the PM.
1.3.6.1.4.1.20044.80.6.1.1.10Scalarpm10010ulhCtrlConf2Flash1read-writecurrentWrite Configuration Tables :This OID saves the current configuration of the PM as configuration2 in the flash. <Help> This control saves the customer configura…
1.3.6.1.4.1.20044.80.6.1.1.14Scalarpm10010ulhCtrlConf2Clear1read-writecurrentClear Configuration Tables :This OID clears the configuration tables from configuration2 in the flash. <Help> This control restores the default configuration o…
1.3.6.1.4.1.20044.80.6.1.4Nodepm10010ulhCtrlsynth4
1.3.6.1.4.1.20044.80.6.1.4.1Scalarpm10010ulhCtrlCorrelatOnread-writecurrentEnable Alarm Correlation :This OID enables the alarm correlation in the PM.
1.3.6.1.4.1.20044.80.6.1.4.2Scalarpm10010ulhCtrlCorrelatOffread-writecurrentDisable Alarm Correlation :This OID disables the alarm correlation in the PM.
1.3.6.1.4.1.20044.80.6.1.5Nodepm10010ulhCtrlswMgnt
1.3.6.1.4.1.20044.80.6.1.5.2Scalarpm10010ulhCtrlColdResetread-writecurrentPM Cold Reset :This OID, when set, causes a cold reset of the PM. This reset is traffic affecting, and the configuration of PM is reloaded on start-up. <Help> …
1.3.6.1.4.1.20044.80.6.1.5.3Scalarpm10010ulhCtrlWarmResetread-writecurrentPM Warm Reset :This OID, when set, causes a warm reset of the PM. This reset is not traffic affecting, and the configuration of PM remains unchanged. <Help> Th…
1.3.6.1.4.1.20044.80.6.1.5.5Scalarpm10010ulhCtrlLoadSwBank1read-writecurrentSet Software Nb 1 As Active :This OID, when set, loads the SW from bank1 into the PM. It must be followed by a reset. <Help> This controls selects the first SW…
1.3.6.1.4.1.20044.80.6.1.5.6Scalarpm10010ulhCtrlLoadSwBank2read-writecurrentSet Software Nb 2 As Active :This OID, when set, loads the SW from bank2 into the PM. It must be followed by a reset. <Help> This controls selects the second S…
1.3.6.1.4.1.20044.80.6.1.6Nodepm10010ulhCtrlgwMgnt
1.3.6.1.4.1.20044.80.6.1.6.1Scalarpm10010ulhCtrlCurrentGwResetread-writecurrentActive Gateware Reset :This OID, when set, resets the active gateware. It is traffic affecting.
1.3.6.1.4.1.20044.80.6.1.6.5Scalarpm10010ulhCtrlLoadGwBank1read-writecurrentSet Gateware Nb 1 As Active :This OID, when set, loads the GW from bank1 (Flash) into the PM. It is followed by an automatic gateware cold reset. <Help> This c…
1.3.6.1.4.1.20044.80.6.1.6.6Scalarpm10010ulhCtrlLoadGwBank2read-writecurrentSet Gateware Nb 2 As Active :This OID, when set, loads the GW from bank2 (Flash) into the PM. It is followed by an automatic gateware cold reset.
1.3.6.1.4.1.20044.80.6.1.6.7Scalarpm10010ulhCtrlLoadGwBank3read-writecurrentSet Gateware Nb 3 As Active :This OID, when set, loads the GW from bank3 (Flash) into the PM. It is followed by an automatic gateware cold reset. <Help> This c…
1.3.6.1.4.1.20044.80.6.1.6.8Scalarpm10010ulhCtrlLoadGwBank4read-writecurrentSet Gateware Nb 4 As Active :This OID, when set, loads the GW from bank4 (Flash) into the PM. It is followed by an automatic gateware cold reset.
1.3.6.1.4.1.20044.80.6.1.192Nodepm10010ulhCtrlledTest
1.3.6.1.4.1.20044.80.6.1.192.1Scalarpm10010ulhCtrlGreenLedread-writecurrentGreen Leds Test :This OID switches on all the green Leds as a test feature. <Help> This control initiates a test leds turning all the LEDs to green
1.3.6.1.4.1.20044.80.6.1.192.2Scalarpm10010ulhCtrlRedLedread-writecurrentRed Leds Test :This OID switches on all the red Leds as a test feature. <Help> This control initiates a test leds turning all the LEDs to red
1.3.6.1.4.1.20044.80.6.1.192.3Scalarpm10010ulhCtrlLedOffread-writecurrentLeds Off :This OID switches off all the Leds as a test feature. <Help> This control initiates a test leds turning all the LEDs to OFF
1.3.6.1.4.1.20044.80.6.1.201Nodepm10010ulhCtrlinitSwitchMarvell
1.3.6.1.4.1.20044.80.6.1.201.1Scalarpm10010ulhCtrlInitSwitchMarvellread-writecurrentSwitch Initialization :This OID operates an initialization of the switch managed through the module <Help> This control activates an initialization of the swit…
1.3.6.1.4.1.20044.80.6.1.259Nodepm10010ulhCtrlresetCount
1.3.6.1.4.1.20044.80.6.1.259.1Scalarpm10010ulhCtrlResetcountread-writecurrentModule Count Global Reset :This OID resets all the errors counters on the module <Help > This control initiates a reset of the errors counters on the module
1.3.6.1.4.1.20044.80.6.1.260Nodepm10010ulhCtrlresetRmon
1.3.6.1.4.1.20044.80.6.1.260.1Scalarpm10010ulhCtrlResetrmonread-writecurrentModule Rmon Global Reset :This OID resets all the Rmon counters on the module <Help > This control initiates a reset of the Rmon counters on the module
1.3.6.1.4.1.20044.80.6.1.261Nodepm10010ulhCtrlresetMeasurements
1.3.6.1.4.1.20044.80.6.1.261.1Scalarpm10010ulhCtrlResetmeasurementsread-writecurrentManagement Meas Global Reset :This OID resets some measurements on the management <Help > This control initiates a reset of some measurements on the management
1.3.6.1.4.1.20044.80.6.2Nodepm10010ulhCtrlClient
1.3.6.1.4.1.20044.80.6.2.16Tablepm10010ulhCtrlaccessLoopTablenot-accessiblecurrentList of pm10010ulhCtrlaccessLoop Article
1.3.6.1.4.1.20044.80.6.2.16.1Rowpm10010ulhCtrlaccessLoopEntrynot-accessiblecurrentRow definition for the pm10010ulhCtrlaccessLoop table
1.3.6.1.4.1.20044.80.6.2.16.1.1Columnpm10010ulhCtrlaccessLoopIndexread-onlycurrentIndex definition for the pm10010ulhCtrlaccessLoop table
1.3.6.1.4.1.20044.80.6.2.16.1.2Columnpm10010ulhCtrlaccessLoopPortnread-writecurrentClient Facility Loopback :This OID, when set at '1' puts the client port in loopback, looping the received 10 Gb/s signal on the transmit 10 Gb/s output. <Help…
1.3.6.1.4.1.20044.80.6.2.17Tablepm10010ulhCtrlclientLoopToLineTablenot-accessiblecurrentList of pm10010ulhCtrlclientLoopToLine Article
1.3.6.1.4.1.20044.80.6.2.17.1Rowpm10010ulhCtrlclientLoopToLineEntrynot-accessiblecurrentRow definition for the pm10010ulhCtrlclientLoopToLine table
1.3.6.1.4.1.20044.80.6.2.17.1.1Columnpm10010ulhCtrlclientLoopToLineIndexread-onlycurrentIndex definition for the pm10010ulhCtrlclientLoopToLine table
1.3.6.1.4.1.20044.80.6.2.17.1.2Columnpm10010ulhCtrlclientLoopToLinePortnread-writecurrentClient Terminal Loopback :This OID, when set, puts the client port in loop back, looping the 10 Gb/s output signal on the 10 Gb/s input.<Help> This control ena…
1.3.6.1.4.1.20044.80.6.2.21Tablepm10010ulhCtrlcsfUpInsTablenot-accessiblecurrentList of pm10010ulhCtrlcsfUpIns Article
1.3.6.1.4.1.20044.80.6.2.21.1Rowpm10010ulhCtrlcsfUpInsEntrynot-accessiblecurrentRow definition for the pm10010ulhCtrlcsfUpIns table
1.3.6.1.4.1.20044.80.6.2.21.1.1Columnpm10010ulhCtrlcsfUpInsIndexread-onlycurrentIndex definition for the pm10010ulhCtrlcsfUpIns table
1.3.6.1.4.1.20044.80.6.2.21.1.2Columnpm10010ulhCtrlcsfUpInsPortnread-writecurrentClient Signal Fail Insertion :This OID, when set, inserts a client signal fail in the upstream client Port. <Help> This control inserts a Client Signal Fail fo…
1.3.6.1.4.1.20044.80.6.2.22Tablepm10010ulhCtrlcaisDwInsTablenot-accessiblecurrentList of pm10010ulhCtrlcaisDwIns Article
1.3.6.1.4.1.20044.80.6.2.22.1Rowpm10010ulhCtrlcaisDwInsEntrynot-accessiblecurrentRow definition for the pm10010ulhCtrlcaisDwIns table
1.3.6.1.4.1.20044.80.6.2.22.1.1Columnpm10010ulhCtrlcaisDwInsIndexread-onlycurrentIndex definition for the pm10010ulhCtrlcaisDwIns table
1.3.6.1.4.1.20044.80.6.2.22.1.2Columnpm10010ulhCtrlcaisDwInsPortnread-writecurrentClient AIS Insertion :This OID, when set, inserts a client AIS on the downstream client Port. <Help> This control inserts a Client AIS for the client port
1.3.6.1.4.1.20044.80.6.2.262Tablepm10010ulhCtrlclientResetAllCountTablenot-accessiblecurrentList of pm10010ulhCtrlclientResetAllCount Article
1.3.6.1.4.1.20044.80.6.2.262.1Rowpm10010ulhCtrlclientResetAllCountEntrynot-accessiblecurrentRow definition for the pm10010ulhCtrlclientResetAllCount table
1.3.6.1.4.1.20044.80.6.2.262.1.1Columnpm10010ulhCtrlclientResetAllCountIndexread-onlycurrentIndex definition for the pm10010ulhCtrlclientResetAllCount table
1.3.6.1.4.1.20044.80.6.2.262.1.2Columnpm10010ulhCtrlclientResetAllCountsPortnread-writecurrentClient Counters Reset :This OID resets every counter on the client port <Help> This control operates a reset on the statistics current ,previous and history cl…
1.3.6.1.4.1.20044.80.6.3Nodepm10010ulhCtrlLine
1.3.6.1.4.1.20044.80.6.3.64Tablepm10010ulhCtrlcommAccessLoopTablenot-accessiblecurrentList of pm10010ulhCtrlcommAccessLoop Article
1.3.6.1.4.1.20044.80.6.3.64.1Rowpm10010ulhCtrlcommAccessLoopEntrynot-accessiblecurrentRow definition for the pm10010ulhCtrlcommAccessLoop table
1.3.6.1.4.1.20044.80.6.3.64.1.1Columnpm10010ulhCtrlcommAccessLoopIndexread-onlycurrentIndex definition for the pm10010ulhCtrlcommAccessLoop table
1.3.6.1.4.1.20044.80.6.3.64.1.2Columnpm10010ulhCtrlcommAccessLoopPortnread-writecurrentLine Terminal Loopback :This OID, when set, puts the module in common access loop back, looping the 200 Gb/s output signal on the 200 Gb/s input.<Help> This co…
1.3.6.1.4.1.20044.80.6.3.66Tablepm10010ulhCtrllineLoopTablenot-accessiblecurrentList of pm10010ulhCtrllineLoop Article
1.3.6.1.4.1.20044.80.6.3.66.1Rowpm10010ulhCtrllineLoopEntrynot-accessiblecurrentRow definition for the pm10010ulhCtrllineLoop table
1.3.6.1.4.1.20044.80.6.3.66.1.1Columnpm10010ulhCtrllineLoopIndexread-onlycurrentIndex definition for the pm10010ulhCtrllineLoop table
1.3.6.1.4.1.20044.80.6.3.66.1.2Columnpm10010ulhCtrllineLoopPortnread-writecurrentLine Facility Loopback :This OID, when set at '1' puts the module in line loopback mode, looping the received 200 Gb/s signal on the transmit 200 Gb/s output. …
1.3.6.1.4.1.20044.80.6.3.69Tablepm10010ulhCtrlfecDisableTablenot-accessiblecurrentList of pm10010ulhCtrlfecDisable Article
1.3.6.1.4.1.20044.80.6.3.69.1Rowpm10010ulhCtrlfecDisableEntrynot-accessiblecurrentRow definition for the pm10010ulhCtrlfecDisable table
1.3.6.1.4.1.20044.80.6.3.69.1.1Columnpm10010ulhCtrlfecDisableIndexread-onlycurrentIndex definition for the pm10010ulhCtrlfecDisable table
1.3.6.1.4.1.20044.80.6.3.69.1.2Columnpm10010ulhCtrlfecDisablePortnread-writecurrentForward Error Correction Inhibition :This OID, when set, inhibits the Forward Error Correction feature on the line input <Help> This control enables/disables t…
1.3.6.1.4.1.20044.80.6.3.209Tablepm10010ulhCtrlmsaLineLoopTablenot-accessiblecurrentList of pm10010ulhCtrlmsaLineLoop Article
1.3.6.1.4.1.20044.80.6.3.209.1Rowpm10010ulhCtrlmsaLineLoopEntrynot-accessiblecurrentRow definition for the pm10010ulhCtrlmsaLineLoop table
1.3.6.1.4.1.20044.80.6.3.209.1.1Columnpm10010ulhCtrlmsaLineLoopIndexread-onlycurrentIndex definition for the pm10010ulhCtrlmsaLineLoop table
1.3.6.1.4.1.20044.80.6.3.209.1.2Columnpm10010ulhCtrlmsaLineLoopPortnread-writecurrentMSA Line Loop :This OID operates a line loopback on the MSA Line <Help> This control defines the line loop back of the line transceiver
1.3.6.1.4.1.20044.80.6.3.210Tablepm10010ulhCtrlmsaTxResetTablenot-accessiblecurrentList of pm10010ulhCtrlmsaTxReset Article
1.3.6.1.4.1.20044.80.6.3.210.1Rowpm10010ulhCtrlmsaTxResetEntrynot-accessiblecurrentRow definition for the pm10010ulhCtrlmsaTxReset table
1.3.6.1.4.1.20044.80.6.3.210.1.1Columnpm10010ulhCtrlmsaTxResetIndexread-onlycurrentIndex definition for the pm10010ulhCtrlmsaTxReset table
1.3.6.1.4.1.20044.80.6.3.210.1.2Columnpm10010ulhCtrlmsaTxResetPortnread-writecurrentLine MSA TX Reset :This OID resets the TX portion of the MSA line module <Help > This control initiates a reset of the transmitting side
1.3.6.1.4.1.20044.80.6.3.211Tablepm10010ulhCtrlmsaRxResetTablenot-accessiblecurrentList of pm10010ulhCtrlmsaRxReset Article
1.3.6.1.4.1.20044.80.6.3.211.1Rowpm10010ulhCtrlmsaRxResetEntrynot-accessiblecurrentRow definition for the pm10010ulhCtrlmsaRxReset table
1.3.6.1.4.1.20044.80.6.3.211.1.1Columnpm10010ulhCtrlmsaRxResetIndexread-onlycurrentIndex definition for the pm10010ulhCtrlmsaRxReset table
1.3.6.1.4.1.20044.80.6.3.211.1.2Columnpm10010ulhCtrlmsaRxResetPortnread-writecurrentLine MSA RX Reset :This OID resets the RX portion of the MSA line module <Help > This control initiates a reset of the receiving side
1.3.6.1.4.1.20044.80.6.3.212Tablepm10010ulhCtrlmsaShutdownTablenot-accessiblecurrentList of pm10010ulhCtrlmsaShutdown Article
1.3.6.1.4.1.20044.80.6.3.212.1Rowpm10010ulhCtrlmsaShutdownEntrynot-accessiblecurrentRow definition for the pm10010ulhCtrlmsaShutdown table
1.3.6.1.4.1.20044.80.6.3.212.1.1Columnpm10010ulhCtrlmsaShutdownIndexread-onlycurrentIndex definition for the pm10010ulhCtrlmsaShutdown table
1.3.6.1.4.1.20044.80.6.3.212.1.2Columnpm10010ulhCtrlmsaShutdownPortnread-writecurrentLine MSA Shutdown :This OID enters a process to shutdown the MSA line module <Help > This control initiates a shutdown of the module
1.3.6.1.4.1.20044.80.6.3.263Tablepm10010ulhCtrllineResetAllCountTablenot-accessiblecurrentList of pm10010ulhCtrllineResetAllCount Article
1.3.6.1.4.1.20044.80.6.3.263.1Rowpm10010ulhCtrllineResetAllCountEntrynot-accessiblecurrentRow definition for the pm10010ulhCtrllineResetAllCount table
1.3.6.1.4.1.20044.80.6.3.263.1.1Columnpm10010ulhCtrllineResetAllCountIndexread-onlycurrentIndex definition for the pm10010ulhCtrllineResetAllCount table
1.3.6.1.4.1.20044.80.6.3.263.1.2Columnpm10010ulhCtrllineResetAllCountsPortnread-writecurrentLine Counters Reset :This OID resets every counter on the line port <Help> This control operates a reset on the statistics current ,previous and history line p…
1.3.6.1.4.1.20044.80.7Nodepm10010ulhri
1.3.6.1.4.1.20044.80.7.1Nodepm10010ulhriTable
1.3.6.1.4.1.20044.80.7.1.1Tablepm10010ulhRinvSfpTablenot-accessiblecurrentList of the SFPs on the selected module
1.3.6.1.4.1.20044.80.7.1.1.1Rowpm10010ulhRinvSfpEntrynot-accessiblecurrentRow definition for the SFP table
1.3.6.1.4.1.20044.80.7.1.1.1.1Columnpm10010ulhRinvSfpIndexread-onlycurrentIndex for SFP table
1.3.6.1.4.1.20044.80.7.1.1.1.2Columnpm10010ulhRinvsfpread-onlycurrentInventory for the SFP: This OID contains the inventory for the SFP
1.3.6.1.4.1.20044.80.7.1.2Tablepm10010ulhRinvLineTablenot-accessiblecurrentList of the XFPs on the selected module
1.3.6.1.4.1.20044.80.7.1.2.1Rowpm10010ulhRinvLineEntrynot-accessiblecurrentRow definition for the XFP table
1.3.6.1.4.1.20044.80.7.1.2.1.1Columnpm10010ulhRinvLineIndexread-onlycurrentIndex for XFP table
1.3.6.1.4.1.20044.80.7.1.2.1.2Columnpm10010ulhRinvxfpLineread-onlycurrentInventory for the XFP: This OID contains the inventory for the XFP
1.3.6.1.4.1.20044.80.7.2Scalarpm10010ulhRinvReloadInventoryread-writecurrentReload the inventory: This OID triggers an inventory reload.
1.3.6.1.4.1.20044.80.7.3Scalarpm10010ulhRinvHwPlatformread-onlycurrentHW platform description: This OID contains the description of the Hardware platform.
1.3.6.1.4.1.20044.80.7.4Scalarpm10010ulhRinvModulePlatformread-onlycurrentModule platform description: This OID contains the description of the Module.
1.3.6.1.4.1.20044.80.7.5Scalarpm10010ulhRinvSwPlatformread-onlycurrentSW platform description: This OID contains the description of the Software platform.
1.3.6.1.4.1.20044.80.7.6Scalarpm10010ulhRinvGwPlatformread-onlycurrentGW platform description: This OID contains the description of the Gateware platform.
1.3.6.1.4.1.20044.80.8Nodepm10010ulhdownload
1.3.6.1.4.1.20044.80.8.1Nodepm10010ulhDwlOther
1.3.6.1.4.1.20044.80.8.1.0Nodepm10010ulhDwlrestartProcess
1.3.6.1.4.1.20044.80.8.1.0.1Scalarpm10010ulhDwlWarmRestartProcessedread-onlycurrentWarm Restart :This OID indicates that the module last restart was a Warm RESTART
1.3.6.1.4.1.20044.80.8.1.0.2Scalarpm10010ulhDwlColdRestartProcessedread-onlycurrentCold Restart :This OID indicates that the module last restart was a Cold RESTART
1.3.6.1.4.1.20044.80.8.1.1Nodepm10010ulhDwlswBanksUsed
1.3.6.1.4.1.20044.80.8.1.1.1Scalarpm10010ulhDwlSwBank1Usedread-onlycurrentSW bank 1 active :This OID indicates the module is working on SW bank 1 <Help> This status indicates if the SW bank 1 is active or standby
1.3.6.1.4.1.20044.80.8.1.1.2Scalarpm10010ulhDwlSwBank2Usedread-onlycurrentSW bank 2 active :This OID indicates the module is working on SW bank 2 <Help> This status indicates if the SW bank 2 is active or standby
1.3.6.1.4.1.20044.80.8.1.1.5Scalarpm10010ulhDwlSwBank1Notemptyread-onlycurrentSW bank 1 loaded :This OID indicates a software is loaded in SW bank 1 <Help> This status indicates if the SW bank 1 contains SW package
1.3.6.1.4.1.20044.80.8.1.1.6Scalarpm10010ulhDwlSwBank2Notemptyread-onlycurrentSW bank 2 loaded :This OID indicates a software is loaded in SW bank 2 <Help> This status indicates if the SW bank 2 contains SW package
1.3.6.1.4.1.20044.80.8.1.2Nodepm10010ulhDwlgwBanksUsed
1.3.6.1.4.1.20044.80.8.1.2.1Scalarpm10010ulhDwlGwBank1Usedread-onlycurrentGW bank 1 active :This OID indicates the module is working on GW bank 1 <Help> This status indicates if the GW bank 1 is active or standby
1.3.6.1.4.1.20044.80.8.1.2.2Scalarpm10010ulhDwlGwBank2Usedread-onlycurrentGW bank 2 active :This OID indicates the module is working on GW bank 2
1.3.6.1.4.1.20044.80.8.1.2.3Scalarpm10010ulhDwlGwBank3Usedread-onlycurrentGW bank 3 active :This OID indicates the module is working on GW bank 3 <Help> This status indicates if the GW bank 3 is active or standby
1.3.6.1.4.1.20044.80.8.1.2.4Scalarpm10010ulhDwlGwBank4Usedread-onlycurrentGW bank 4 active :This OID indicates the module is working on GW bank 4
1.3.6.1.4.1.20044.80.8.1.2.5Scalarpm10010ulhDwlGwBank1Notemptyread-onlycurrentGW bank 1 loaded :This OID indicates a gateware is loaded in GW bank 1 <Help> This status indicates if the GW bank 1 contains GW package
1.3.6.1.4.1.20044.80.8.1.2.6Scalarpm10010ulhDwlGwBank2Notemptyread-onlycurrentGW bank 2 loaded :This OID indicates a gateware is loaded in GW bank 2
1.3.6.1.4.1.20044.80.8.1.2.7Scalarpm10010ulhDwlGwBank3Notemptyread-onlycurrentGW bank 3 loaded :This OID indicates a gateware is loaded in GW bank 3 <Help> This status indicates if the GW bank 3 contains GW package
1.3.6.1.4.1.20044.80.8.1.2.8Scalarpm10010ulhDwlGwBank4Notemptyread-onlycurrentGW bank 4 loaded :This OID indicates a gateware is loaded in GW bank 4
1.3.6.1.4.1.20044.80.8.2Nodepm10010ulhDwlClient
1.3.6.1.4.1.20044.80.8.3Nodepm10010ulhDwlLine
1.3.6.1.4.1.20044.80.9Nodepm10010ulhConfig
1.3.6.1.4.1.20044.80.9.1Nodepm10010ulhCfgAccessCAisCsf
1.3.6.1.4.1.20044.80.9.1.1Tablepm10010ulhCfgClientcaiscsfTablenot-accessiblecurrentList of Article
1.3.6.1.4.1.20044.80.9.1.1.1Rowpm10010ulhCfgClientcaiscsfEntrynot-accessiblecurrentRow definition for the accessCAisCsf table
1.3.6.1.4.1.20044.80.9.1.1.1.1Columnpm10010ulhCfgClientcaiscsfIndexread-onlycurrentIndex definition for the clientcaiscsf table
1.3.6.1.4.1.20044.80.9.1.1.1.3Columnpm10010ulhCfgReservePortnread-writecurrentCAIS mode on Client Port :This register enables/disables port laser shutdown on CAIS insertion condition
1.3.6.1.4.1.20044.80.9.2Nodepm10010ulhCfgStartup
1.3.6.1.4.1.20044.80.9.2.1Tablepm10010ulhCfgClientStartupTablenot-accessiblecurrentList of Article
1.3.6.1.4.1.20044.80.9.2.1.1Rowpm10010ulhCfgClientStartupEntrynot-accessiblecurrentRow definition for the startup table
1.3.6.1.4.1.20044.80.9.2.1.1.1Columnpm10010ulhCfgClientStartupIndexread-onlycurrentIndex definition for the clientStartup table
1.3.6.1.4.1.20044.80.9.2.1.1.3Columnpm10010ulhCfgSystConfPortPortnread-writecurrentDefault Settings on Client Port :This register configures the default initialisation settings on the port.
1.3.6.1.4.1.20044.80.9.2.1.1.4Columnpm10010ulhCfgNetConfPortPortnread-writecurrentDefault Settings on Client Port :This register configures the default initialisation settings on the port.
1.3.6.1.4.1.20044.80.9.2.1.1.14Columnpm10010ulhCfgOptionsPortPortnread-writecurrentDefault Options on Client Port :This register configures the default options on the port.
1.3.6.1.4.1.20044.80.9.2.2Tablepm10010ulhCfgLineStartupTablenot-accessiblecurrentList of Article
1.3.6.1.4.1.20044.80.9.2.2.1Rowpm10010ulhCfgLineStartupEntrynot-accessiblecurrentRow definition for the startup table
1.3.6.1.4.1.20044.80.9.2.2.1.1Columnpm10010ulhCfgLineStartupIndexread-onlycurrentIndex definition for the lineStartup table
1.3.6.1.4.1.20044.80.9.2.2.1.3Columnpm10010ulhCfgSystConfLinePortnread-writecurrentDefault Settings on Line :This register configures the default initialisation settings on Line
1.3.6.1.4.1.20044.80.9.2.2.1.14Columnpm10010ulhCfgOptionsLinePortnread-writecurrentDefault Options on Line :This register configures the default options on the line
1.3.6.1.4.1.20044.80.9.2.3Tablepm10010ulhCfgXfpTablenot-accessiblecurrentList of Article
1.3.6.1.4.1.20044.80.9.2.3.1Rowpm10010ulhCfgXfpEntrynot-accessiblecurrentRow definition for the startup table
1.3.6.1.4.1.20044.80.9.2.3.1.1Columnpm10010ulhCfgXfpIndexread-onlycurrentIndex definition for the xfp table
1.3.6.1.4.1.20044.80.9.2.3.1.3Columnpm10010ulhCfgSystConfMsaLinePortnread-writecurrentDefault settings on MSA :This register configures the default initialisation settings on MSA
1.3.6.1.4.1.20044.80.9.3Nodepm10010ulhCfgLabels
1.3.6.1.4.1.20044.80.9.3.1Tablepm10010ulhCfgLabelclientTablenot-accessiblecurrentList of Article
1.3.6.1.4.1.20044.80.9.3.1.1Rowpm10010ulhCfgLabelclientEntrynot-accessiblecurrentRow definition for the labels table
1.3.6.1.4.1.20044.80.9.3.1.1.1Columnpm10010ulhCfgLabelclientIndexread-onlycurrentIndex definition for the labelclient table
1.3.6.1.4.1.20044.80.9.3.1.1.3Columnpm10010ulhCfgLabelclientPortnread-writecurrentDefault settings on the label of the Ports :These registers configures the default initialisation settings of the labels of the ports.
1.3.6.1.4.1.20044.80.9.3.2Tablepm10010ulhCfgLabellineTablenot-accessiblecurrentList of Article
1.3.6.1.4.1.20044.80.9.3.2.1Rowpm10010ulhCfgLabellineEntrynot-accessiblecurrentRow definition for the labels table
1.3.6.1.4.1.20044.80.9.3.2.1.1Columnpm10010ulhCfgLabellineIndexread-onlycurrentIndex definition for the labelline table
1.3.6.1.4.1.20044.80.9.3.2.1.3Columnpm10010ulhCfgLabellinePortnread-writecurrentDefault settings on the label of the lines :These registers configures the default initialisation settings of the labels of the lines.
1.3.6.1.4.1.20044.80.9.4Nodepm10010ulhCfgStartuptlh
1.3.6.1.4.1.20044.80.9.4.1Tablepm10010ulhCfgOtxtlhTablenot-accessiblecurrentList of Article
1.3.6.1.4.1.20044.80.9.4.1.1Rowpm10010ulhCfgOtxtlhEntrynot-accessiblecurrentRow definition for the startuptlh table
1.3.6.1.4.1.20044.80.9.4.1.1.1Columnpm10010ulhCfgOtxtlhIndexread-onlycurrentIndex definition for the otxtlh table
1.3.6.1.4.1.20044.80.9.4.1.1.6Columnpm10010ulhCfgLinePwrLaserPortnread-writecurrentDefaut Line output Power :This register configures the start-up output power of the Line tranceiver (Unit = dBm)
1.3.6.1.4.1.20044.80.9.4.1.1.7Columnpm10010ulhCfgLineFCurrentPortnread-writecurrentDefault Line transceiver Tx Channel :This register configures the start-up laser channel of the Line Tx transceiver
1.3.6.1.4.1.20044.80.9.4.1.1.8Columnpm10010ulhCfgLineGridCurrentPortnread-writecurrentDefault Line transceiver Grid :This register configures the start-up laser grid of the Line transceiver
1.3.6.1.4.1.20044.80.9.4.1.1.9Columnpm10010ulhCfgFPortnread-writecurrentDefault Line TRX lowest Freq :This register configures the start-up lowest frequency of the Line transceiver
1.3.6.1.4.1.20044.80.9.4.1.1.10Columnpm10010ulhCfgRxLineFCurrentPortnread-writecurrentDefault Line transceiver Rx Channel :This register configures the start-up laser channel of the Line Rx transceiver
1.3.6.1.4.1.20044.80.9.5Nodepm10010ulhCfgOther
1.3.6.1.4.1.20044.80.9.5.1Nodepm10010ulhtablemoduleOther
1.3.6.1.4.1.20044.80.9.5.1.2Scalarpm10010ulhCfgmoderead-writecurrentDefault settings on Module :This register selects the configuration mode of the module
1.3.6.1.4.1.20044.80.9.5.1.3Scalarpm10010ulhCfgfanLowSpeedThresholdread-writecurrentDefault settings on Module :This register selects the speed threshold of the fan's
1.3.6.1.4.1.20044.80.9.5.1.4Scalarpm10010ulhCfgfanHighSpeedThresholdread-writecurrentDefault settings on Module :This register selects the speed threshold of the fan's
1.3.6.1.4.1.20044.80.9.6Nodepm10010ulhCfgStartuptablefive
1.3.6.1.4.1.20044.80.9.6.1Tablepm10010ulhCfgOtxtlhcapabilitiesTablenot-accessiblecurrentList of Article
1.3.6.1.4.1.20044.80.9.6.1.1Rowpm10010ulhCfgOtxtlhcapabilitiesEntrynot-accessiblecurrentRow definition for the startuptablefive table
1.3.6.1.4.1.20044.80.9.6.1.1.1Columnpm10010ulhCfgOtxtlhcapabilitiesIndexread-onlycurrentIndex definition for the otxtlhcapabilities table
1.3.6.1.4.1.20044.80.9.6.1.1.3Columnpm10010ulhCfgComponentTypePortnread-onlycurrentComponent parameters :This OID defines the component parameters
1.3.6.1.4.1.20044.80.9.6.1.1.4Columnpm10010ulhCfgMiscellaneousPortnread-onlycurrentMiscellaneous default settings :This OID defines the miscellaneous parameters
1.3.6.1.4.1.20044.80.9.6.1.1.5Columnpm10010ulhCfgFirstChannelPortnread-onlycurrentNumber of the first channel of the component :This OID defines the first channel number of the PM
1.3.6.1.4.1.20044.80.9.6.1.1.6Columnpm10010ulhCfgLastChannelPortnread-onlycurrentNumber of the last channel of the component :This OID defines the last channel number of the PM
1.3.6.1.4.1.20044.80.9.6.1.1.7Columnpm10010ulhCfgGridPortnread-onlycurrentGrid value of the component :This OID defines the grid of the PM
1.3.6.1.4.1.20044.80.9.257Scalarpm10010ulhCfgWriteConfigurationread-writecurrentWrite configuration to module:This OID writes the complete configuration to the module
1.3.6.1.4.1.20044.80.10Nodepm10010ulhtraps
1.3.6.1.4.1.20044.80.10.2Scalarpm10010ulhtrapPortNumberread-onlycurrentLast port which generates a trap
1.3.6.1.4.1.20044.80.10.3Scalarpm10010ulhtrapLineNumberread-onlycurrentLast Line which generates a trap
1.3.6.1.4.1.20044.80.10.4Scalarpm10010ulhtrapBoardNumberread-onlycurrentLast module which generates a trap
1.3.6.1.4.1.20044.80.10.30Notificationpm10010ulhLineTrapNotUrgentGoesOncurrentNot urgent Line default is activated
1.3.6.1.4.1.20044.80.10.31Notificationpm10010ulhLineTrapNotUrgentGoesOffcurrentNot urgent Line default disappeared
1.3.6.1.4.1.20044.80.10.32Notificationpm10010ulhLineTrapUrgentGoesOncurrentUrgent Line default is activated
1.3.6.1.4.1.20044.80.10.33Notificationpm10010ulhLineTrapUrgentGoesOffcurrentUrgent Line default disappeared
1.3.6.1.4.1.20044.80.10.34Notificationpm10010ulhLineTrapCritGoesOncurrentCritical Line default is activated
1.3.6.1.4.1.20044.80.10.35Notificationpm10010ulhLineTrapCritGoesOffcurrentCritical Line default disappeared
1.3.6.1.4.1.20044.80.10.40Notificationpm10010ulhClientTrapNotUrgentGoesOncurrentNot urgent client default is activated
1.3.6.1.4.1.20044.80.10.41Notificationpm10010ulhClientTrapNotUrgentGoesOffcurrentNot urgent client default disappeared
1.3.6.1.4.1.20044.80.10.42Notificationpm10010ulhClientTrapUrgentGoesOncurrentUrgent client default is activated
1.3.6.1.4.1.20044.80.10.43Notificationpm10010ulhClientTrapUrgentGoesOffcurrentUrgent client default disappeared
1.3.6.1.4.1.20044.80.10.44Notificationpm10010ulhClientTrapCritGoesOncurrentCritical client default is activated
1.3.6.1.4.1.20044.80.10.45Notificationpm10010ulhClientTrapCritGoesOffcurrentCritical client default disappeared
1.3.6.1.4.1.20044.80.10.50Notificationpm10010ulhPowerTrapUrgentGoesOncurrentUrgent power supply default is activated
1.3.6.1.4.1.20044.80.10.51Notificationpm10010ulhPowerTrapUrgentGoesOffcurrentUrgent power supply default disappeared
1.3.6.1.4.1.20044.80.11Nodepm10010ulhMonitoring
1.3.6.1.4.1.20044.80.11.1Nodepm10010ulhMonOther
1.3.6.1.4.1.20044.80.11.1.3Nodepm10010ulhMonRmon
1.3.6.1.4.1.20044.80.11.2Nodepm10010ulhMonClient
1.3.6.1.4.1.20044.80.11.2.4Nodepm10010ulhMonClientRmonCounter
1.3.6.1.4.1.20044.80.11.2.4.16Tablepm10010ulhMonupRmonBytesCounterClientInputTablenot-accessiblecurrentList of pm10010ulhMonupRmonBytesCounterClientInput Article
1.3.6.1.4.1.20044.80.11.2.4.16.1Rowpm10010ulhMonupRmonBytesCounterClientInputEntrynot-accessiblecurrentRow definition for the pm10010ulhMonupRmonBytesCounterClientInput table
1.3.6.1.4.1.20044.80.11.2.4.16.1.1Columnpm10010ulhMonupRmonBytesCounterClientInputIndexread-onlycurrentIndex definition for the pm10010ulhMonupRmonBytesCounterClientInput table
1.3.6.1.4.1.20044.80.11.2.4.16.1.2Columnpm10010ulhMonupRmonBytesCounterClientInputValuePortnread-onlycurrentClient Input Bytes :This counter is increased each time a data byte is received on the client port <Help> This counter gives the number of bytes received on th…
1.3.6.1.4.1.20044.80.11.2.4.16.1.3Columnpm10010ulhMonupRmonBytesCounterClientInputErrorPortnread-onlycurrentBytes Counter Error :This OID when set indicates the Bytes counter value is invalid on client port
1.3.6.1.4.1.20044.80.11.2.4.16.1.4Columnpm10010ulhMonupRmonBytesCounterClientInputOverloadPortnread-onlycurrentBytes Counter Overload :This OID when set indicates a Bytes counter overload on client port
1.3.6.1.4.1.20044.80.11.2.4.48Tablepm10010ulhMonupRmonCrcErrorsCounterClientInputTablenot-accessiblecurrentList of pm10010ulhMonupRmonCrcErrorsCounterClientInput Article
1.3.6.1.4.1.20044.80.11.2.4.48.1Rowpm10010ulhMonupRmonCrcErrorsCounterClientInputEntrynot-accessiblecurrentRow definition for the pm10010ulhMonupRmonCrcErrorsCounterClientInput table
1.3.6.1.4.1.20044.80.11.2.4.48.1.1Columnpm10010ulhMonupRmonCrcErrorsCounterClientInputIndexread-onlycurrentIndex definition for the pm10010ulhMonupRmonCrcErrorsCounterClientInput table
1.3.6.1.4.1.20044.80.11.2.4.48.1.2Columnpm10010ulhMonupRmonCrcErrorsCounterClientInputValuePortnread-onlycurrentClient Input CRC Errors :This counter is increased each time a CRC error is detected on the client port<Help> This counter gives the number of CRC Errors recei…
1.3.6.1.4.1.20044.80.11.2.4.48.1.3Columnpm10010ulhMonupRmonCrcErrorsCounterClientInputErrorPortnread-onlycurrentCRC Errors Counter Error :This OID when set indicates the CRC Errors counter value is invalid on client port
1.3.6.1.4.1.20044.80.11.2.4.48.1.4Columnpm10010ulhMonupRmonCrcErrorsCounterClientInputOverloadPortnread-onlycurrentCRC Errors Counter Overload :This OID when set indicates a CRC Errors counter overload on client port
1.3.6.1.4.1.20044.80.11.2.4.80Tablepm10010ulhMonupRmonPacketsCounterClientInputTablenot-accessiblecurrentList of pm10010ulhMonupRmonPacketsCounterClientInput Article
1.3.6.1.4.1.20044.80.11.2.4.80.1Rowpm10010ulhMonupRmonPacketsCounterClientInputEntrynot-accessiblecurrentRow definition for the pm10010ulhMonupRmonPacketsCounterClientInput table
1.3.6.1.4.1.20044.80.11.2.4.80.1.1Columnpm10010ulhMonupRmonPacketsCounterClientInputIndexread-onlycurrentIndex definition for the pm10010ulhMonupRmonPacketsCounterClientInput table
1.3.6.1.4.1.20044.80.11.2.4.80.1.2Columnpm10010ulhMonupRmonPacketsCounterClientInputValuePortnread-onlycurrentClient Input Packets :This counter is increased each time a packet is received on the client port <Help> This counter gives the number of packets received on t…
1.3.6.1.4.1.20044.80.11.2.4.80.1.3Columnpm10010ulhMonupRmonPacketsCounterClientInputErrorPortnread-onlycurrentPackets Counter Error :This OID when set indicates the Packets counter value is invalid on client port
1.3.6.1.4.1.20044.80.11.2.4.80.1.4Columnpm10010ulhMonupRmonPacketsCounterClientInputOverloadPortnread-onlycurrentPackets Counter Overload :This OID when set indicates a Packets counter overload on client port
1.3.6.1.4.1.20044.80.11.2.4.112Tablepm10010ulhMonupRmonBroadcastCounterClientInputTablenot-accessiblecurrentList of pm10010ulhMonupRmonBroadcastCounterClientInput Article
1.3.6.1.4.1.20044.80.11.2.4.112.1Rowpm10010ulhMonupRmonBroadcastCounterClientInputEntrynot-accessiblecurrentRow definition for the pm10010ulhMonupRmonBroadcastCounterClientInput table
1.3.6.1.4.1.20044.80.11.2.4.112.1.1Columnpm10010ulhMonupRmonBroadcastCounterClientInputIndexread-onlycurrentIndex definition for the pm10010ulhMonupRmonBroadcastCounterClientInput table
1.3.6.1.4.1.20044.80.11.2.4.112.1.2Columnpm10010ulhMonupRmonBroadcastCounterClientInputValuePortnread-onlycurrentClient Input Broadcast Packets :This counter is increased each time a broadcast packet is received on the client port <Help> This counter gives the number of B…
1.3.6.1.4.1.20044.80.11.2.4.112.1.3Columnpm10010ulhMonupRmonBroadcastCounterClientInputErrorPortnread-onlycurrentBroadcast Counter Error :This OID when set indicates the Broadcast counter value is invalid on client port
1.3.6.1.4.1.20044.80.11.2.4.112.1.4Columnpm10010ulhMonupRmonBroadcastCounterClientInputOverloadPortnread-onlycurrentBroadcast Counter Overload :This OID when set indicates a Broadcast counter overload on client port
1.3.6.1.4.1.20044.80.11.2.4.144Tablepm10010ulhMonupRmonMulticastCounterClientInputTablenot-accessiblecurrentList of pm10010ulhMonupRmonMulticastCounterClientInput Article
1.3.6.1.4.1.20044.80.11.2.4.144.1Rowpm10010ulhMonupRmonMulticastCounterClientInputEntrynot-accessiblecurrentRow definition for the pm10010ulhMonupRmonMulticastCounterClientInput table
1.3.6.1.4.1.20044.80.11.2.4.144.1.1Columnpm10010ulhMonupRmonMulticastCounterClientInputIndexread-onlycurrentIndex definition for the pm10010ulhMonupRmonMulticastCounterClientInput table
1.3.6.1.4.1.20044.80.11.2.4.144.1.2Columnpm10010ulhMonupRmonMulticastCounterClientInputValuePortnread-onlycurrentClient Input Multicast Packets :This counter is increased each time a Multicast packet is received on the client port <Help> This counter gives the number of M…
1.3.6.1.4.1.20044.80.11.2.4.144.1.3Columnpm10010ulhMonupRmonMulticastCounterClientInputErrorPortnread-onlycurrentMulticast Counter Error :This OID when set indicates the Multicast counter value is invalid on client port
1.3.6.1.4.1.20044.80.11.2.4.144.1.4Columnpm10010ulhMonupRmonMulticastCounterClientInputOverloadPortnread-onlycurrentMulticast Counter Overload :This OID when set indicates a Multicast counter overload on client port
1.3.6.1.4.1.20044.80.11.2.4.176Tablepm10010ulhMonupRmonPauseFrameCounterClientInputTablenot-accessiblecurrentList of pm10010ulhMonupRmonPauseFrameCounterClientInput Article
1.3.6.1.4.1.20044.80.11.2.4.176.1Rowpm10010ulhMonupRmonPauseFrameCounterClientInputEntrynot-accessiblecurrentRow definition for the pm10010ulhMonupRmonPauseFrameCounterClientInput table
1.3.6.1.4.1.20044.80.11.2.4.176.1.1Columnpm10010ulhMonupRmonPauseFrameCounterClientInputIndexread-onlycurrentIndex definition for the pm10010ulhMonupRmonPauseFrameCounterClientInput table
1.3.6.1.4.1.20044.80.11.2.4.176.1.2Columnpm10010ulhMonupRmonPauseFrameCounterClientInputValuePortnread-onlycurrentClient Input Pause Frames :This counter is increased each time a Pause frame is received on the client port <Help> This counter gives the number of Pause frame…
1.3.6.1.4.1.20044.80.11.2.4.176.1.3Columnpm10010ulhMonupRmonPauseFrameCounterClientInputErrorPortnread-onlycurrentPause Counter Error :This OID when set indicates the Pause counter value is invalid on client port
1.3.6.1.4.1.20044.80.11.2.4.176.1.4Columnpm10010ulhMonupRmonPauseFrameCounterClientInputOverloadPortnread-onlycurrentPause Counter Overload :This OID when set indicates a Pause counter overload on client port
1.3.6.1.4.1.20044.80.11.2.4.304Tablepm10010ulhMonupRmonUnicastCounterClientInputTablenot-accessiblecurrentList of pm10010ulhMonupRmonUnicastCounterClientInput Article
1.3.6.1.4.1.20044.80.11.2.4.304.1Rowpm10010ulhMonupRmonUnicastCounterClientInputEntrynot-accessiblecurrentRow definition for the pm10010ulhMonupRmonUnicastCounterClientInput table
1.3.6.1.4.1.20044.80.11.2.4.304.1.1Columnpm10010ulhMonupRmonUnicastCounterClientInputIndexread-onlycurrentIndex definition for the pm10010ulhMonupRmonUnicastCounterClientInput table
1.3.6.1.4.1.20044.80.11.2.4.304.1.2Columnpm10010ulhMonupRmonUnicastCounterClientInputValuePortnread-onlycurrentClient Input Unicast Packets :This counter is increased each time a Unicast packet is received on the client port <Help> This counter gives the number of Unica…
1.3.6.1.4.1.20044.80.11.2.4.304.1.3Columnpm10010ulhMonupRmonUnicastCounterClientInputErrorPortnread-onlycurrentUnicast Counter Error :This OID when set indicates the Unicast counter value is invalid on client port
1.3.6.1.4.1.20044.80.11.2.4.304.1.4Columnpm10010ulhMonupRmonUnicastCounterClientInputOverloadPortnread-onlycurrentUnicast Counter Overload :This OID when set indicates a Unicast counter overload on client port
1.3.6.1.4.1.20044.80.11.2.4.336Tablepm10010ulhMonupRmonNonunicastCounterClientInputTablenot-accessiblecurrentList of pm10010ulhMonupRmonNonunicastCounterClientInput Article
1.3.6.1.4.1.20044.80.11.2.4.336.1Rowpm10010ulhMonupRmonNonunicastCounterClientInputEntrynot-accessiblecurrentRow definition for the pm10010ulhMonupRmonNonunicastCounterClientInput table
1.3.6.1.4.1.20044.80.11.2.4.336.1.1Columnpm10010ulhMonupRmonNonunicastCounterClientInputIndexread-onlycurrentIndex definition for the pm10010ulhMonupRmonNonunicastCounterClientInput table
1.3.6.1.4.1.20044.80.11.2.4.336.1.2Columnpm10010ulhMonupRmonNonunicastCounterClientInputValuePortnread-onlycurrentClient Input Non Unicast Packets :This counter is increased each time a Non-Unicast packet is received on the client port <Help> This counter gives the number …
1.3.6.1.4.1.20044.80.11.2.4.336.1.3Columnpm10010ulhMonupRmonNonunicastCounterClientInputErrorPortnread-onlycurrentNon Unicast Counter Error :This OID when set indicates the Non-Unicast counter value is invalid on client port
1.3.6.1.4.1.20044.80.11.2.4.336.1.4Columnpm10010ulhMonupRmonNonunicastCounterClientInputOverloadPortnread-onlycurrentNon Unicast Counter Overload :This OID when set indicates a Non-Unicast counter overload on client port
1.3.6.1.4.1.20044.80.11.2.4.400Tablepm10010ulhMondownRmonBytesCounterClientOutputTablenot-accessiblecurrentList of pm10010ulhMondownRmonBytesCounterClientOutput Article
1.3.6.1.4.1.20044.80.11.2.4.400.1Rowpm10010ulhMondownRmonBytesCounterClientOutputEntrynot-accessiblecurrentRow definition for the pm10010ulhMondownRmonBytesCounterClientOutput table
1.3.6.1.4.1.20044.80.11.2.4.400.1.1Columnpm10010ulhMondownRmonBytesCounterClientOutputIndexread-onlycurrentIndex definition for the pm10010ulhMondownRmonBytesCounterClientOutput table
1.3.6.1.4.1.20044.80.11.2.4.400.1.2Columnpm10010ulhMondownRmonBytesCounterClientOutputValuePortnread-onlycurrentClient Output Bytes :This counter is increased each time a data byte is transmitted on the client port <Help> This counter gives the number of bytes transmitte…
1.3.6.1.4.1.20044.80.11.2.4.400.1.3Columnpm10010ulhMondownRmonBytesCounterClientOutputErrorPortnread-onlycurrentBytes Counter Error :This OID when set indicates the Bytes counter value is invalid on client port
1.3.6.1.4.1.20044.80.11.2.4.400.1.4Columnpm10010ulhMondownRmonBytesCounterClientOutputOverloadPortnread-onlycurrentBytes Counter Overload :This OID when set indicates a Bytes counter overload on client port
1.3.6.1.4.1.20044.80.11.2.4.432Tablepm10010ulhMondownRmonCrcErrorsCounterClientOutputTablenot-accessiblecurrentList of pm10010ulhMondownRmonCrcErrorsCounterClientOutput Article
1.3.6.1.4.1.20044.80.11.2.4.432.1Rowpm10010ulhMondownRmonCrcErrorsCounterClientOutputEntrynot-accessiblecurrentRow definition for the pm10010ulhMondownRmonCrcErrorsCounterClientOutput table
1.3.6.1.4.1.20044.80.11.2.4.432.1.1Columnpm10010ulhMondownRmonCrcErrorsCounterClientOutputIndexread-onlycurrentIndex definition for the pm10010ulhMondownRmonCrcErrorsCounterClientOutput table
1.3.6.1.4.1.20044.80.11.2.4.432.1.2Columnpm10010ulhMondownRmonCrcErrorsCounterClientOutputValuePortnread-onlycurrentClient Output CRC Errors :This counter is increased each time a CRC error is detected on the transmit client port <Help> This counter gives the number of CRC E…
1.3.6.1.4.1.20044.80.11.2.4.432.1.3Columnpm10010ulhMondownRmonCrcErrorsCounterClientOutputErrorPortnread-onlycurrentCRC Errors Counter Error :This OID when set indicates the CRC Errors counter value is invalid on client port
1.3.6.1.4.1.20044.80.11.2.4.432.1.4Columnpm10010ulhMondownRmonCrcErrorsCounterClientOutputOverloadPortnread-onlycurrentCRC Errors Counter Overload :This OID when set indicates a CRC Errors counter overload on client port
1.3.6.1.4.1.20044.80.11.2.4.464Tablepm10010ulhMondownRmonPacketsCounterClientOutputTablenot-accessiblecurrentList of pm10010ulhMondownRmonPacketsCounterClientOutput Article
1.3.6.1.4.1.20044.80.11.2.4.464.1Rowpm10010ulhMondownRmonPacketsCounterClientOutputEntrynot-accessiblecurrentRow definition for the pm10010ulhMondownRmonPacketsCounterClientOutput table
1.3.6.1.4.1.20044.80.11.2.4.464.1.1Columnpm10010ulhMondownRmonPacketsCounterClientOutputIndexread-onlycurrentIndex definition for the pm10010ulhMondownRmonPacketsCounterClientOutput table
1.3.6.1.4.1.20044.80.11.2.4.464.1.2Columnpm10010ulhMondownRmonPacketsCounterClientOutputValuePortnread-onlycurrentClient Output Packets :This counter is increased each time a packet is transmitted on the client port <Help> This counter gives the number of packets transmitt…
1.3.6.1.4.1.20044.80.11.2.4.464.1.3Columnpm10010ulhMondownRmonPacketsCounterClientOutputErrorPortnread-onlycurrentPackets Counter Error :This OID when set indicates the Packets counter value is invalid on client port
1.3.6.1.4.1.20044.80.11.2.4.464.1.4Columnpm10010ulhMondownRmonPacketsCounterClientOutputOverloadPortnread-onlycurrentPackets Counter Overload :This OID when set indicates a Packets counter overload on client port
1.3.6.1.4.1.20044.80.11.2.4.496Tablepm10010ulhMondownRmonBroadcastCounterClientOutputTablenot-accessiblecurrentList of pm10010ulhMondownRmonBroadcastCounterClientOutput Article
1.3.6.1.4.1.20044.80.11.2.4.496.1Rowpm10010ulhMondownRmonBroadcastCounterClientOutputEntrynot-accessiblecurrentRow definition for the pm10010ulhMondownRmonBroadcastCounterClientOutput table
1.3.6.1.4.1.20044.80.11.2.4.496.1.1Columnpm10010ulhMondownRmonBroadcastCounterClientOutputIndexread-onlycurrentIndex definition for the pm10010ulhMondownRmonBroadcastCounterClientOutput table
1.3.6.1.4.1.20044.80.11.2.4.496.1.2Columnpm10010ulhMondownRmonBroadcastCounterClientOutputValuePortnread-onlycurrentClient Output Broadcast Packets :This counter is increased each time a broadcast packet is transmitted on the client port <Help> This counter gives the number …
1.3.6.1.4.1.20044.80.11.2.4.496.1.3Columnpm10010ulhMondownRmonBroadcastCounterClientOutputErrorPortnread-onlycurrentBroadcast Counter Error :This OID when set indicates the Broadcast counter value is invalid on client port
1.3.6.1.4.1.20044.80.11.2.4.496.1.4Columnpm10010ulhMondownRmonBroadcastCounterClientOutputOverloadPortnread-onlycurrentBroadcast Counter Overload :This OID when set indicates a Broadcast counter overload on client port
1.3.6.1.4.1.20044.80.11.2.4.528Tablepm10010ulhMondownRmonMulticastCounterClientOutputTablenot-accessiblecurrentList of pm10010ulhMondownRmonMulticastCounterClientOutput Article
1.3.6.1.4.1.20044.80.11.2.4.528.1Rowpm10010ulhMondownRmonMulticastCounterClientOutputEntrynot-accessiblecurrentRow definition for the pm10010ulhMondownRmonMulticastCounterClientOutput table
1.3.6.1.4.1.20044.80.11.2.4.528.1.1Columnpm10010ulhMondownRmonMulticastCounterClientOutputIndexread-onlycurrentIndex definition for the pm10010ulhMondownRmonMulticastCounterClientOutput table
1.3.6.1.4.1.20044.80.11.2.4.528.1.2Columnpm10010ulhMondownRmonMulticastCounterClientOutputValuePortnread-onlycurrentClient Output Multicast Packets :This counter is increased each time a Multicast packet is transmitted on the client port <Help> This counter gives the number …
1.3.6.1.4.1.20044.80.11.2.4.528.1.3Columnpm10010ulhMondownRmonMulticastCounterClientOutputErrorPortnread-onlycurrentMulticast Counter Error :This OID when set indicates the Multicast counter value is invalid on client port
1.3.6.1.4.1.20044.80.11.2.4.528.1.4Columnpm10010ulhMondownRmonMulticastCounterClientOutputOverloadPortnread-onlycurrentMulticast Counter Overload :This OID when set indicates a Multicast counter overload on client port
1.3.6.1.4.1.20044.80.11.2.4.560Tablepm10010ulhMondownRmonPauseFrameCounterClientOutputTablenot-accessiblecurrentList of pm10010ulhMondownRmonPauseFrameCounterClientOutput Article
1.3.6.1.4.1.20044.80.11.2.4.560.1Rowpm10010ulhMondownRmonPauseFrameCounterClientOutputEntrynot-accessiblecurrentRow definition for the pm10010ulhMondownRmonPauseFrameCounterClientOutput table
1.3.6.1.4.1.20044.80.11.2.4.560.1.1Columnpm10010ulhMondownRmonPauseFrameCounterClientOutputIndexread-onlycurrentIndex definition for the pm10010ulhMondownRmonPauseFrameCounterClientOutput table
1.3.6.1.4.1.20044.80.11.2.4.560.1.2Columnpm10010ulhMondownRmonPauseFrameCounterClientOutputValuePortnread-onlycurrentClient Output Pause Frames :This counter is increased each time a Pause frame is transmitted on the client port <Help> This counter gives the number of Pause f…
1.3.6.1.4.1.20044.80.11.2.4.560.1.3Columnpm10010ulhMondownRmonPauseFrameCounterClientOutputErrorPortnread-onlycurrentPause Counter Error :This OID when set indicates the Pause counter value is invalid on client port
1.3.6.1.4.1.20044.80.11.2.4.560.1.4Columnpm10010ulhMondownRmonPauseFrameCounterClientOutputOverloadPortnread-onlycurrentPause Counter Overload :This OID when set indicates a Pause counter overload on client port
1.3.6.1.4.1.20044.80.11.2.4.688Tablepm10010ulhMondownRmonUnicastCounterClientOutputTablenot-accessiblecurrentList of pm10010ulhMondownRmonUnicastCounterClientOutput Article
1.3.6.1.4.1.20044.80.11.2.4.688.1Rowpm10010ulhMondownRmonUnicastCounterClientOutputEntrynot-accessiblecurrentRow definition for the pm10010ulhMondownRmonUnicastCounterClientOutput table
1.3.6.1.4.1.20044.80.11.2.4.688.1.1Columnpm10010ulhMondownRmonUnicastCounterClientOutputIndexread-onlycurrentIndex definition for the pm10010ulhMondownRmonUnicastCounterClientOutput table
1.3.6.1.4.1.20044.80.11.2.4.688.1.2Columnpm10010ulhMondownRmonUnicastCounterClientOutputValuePortnread-onlycurrentClient Output Unicast Packets :This counter is increased each time a Unicast packet is transmitted on the client port <Help> This counter gives the number of U…
1.3.6.1.4.1.20044.80.11.2.4.688.1.3Columnpm10010ulhMondownRmonUnicastCounterClientOutputErrorPortnread-onlycurrentUnicast Counter Error :This OID when set indicates the Unicast counter value is invalid on client port
1.3.6.1.4.1.20044.80.11.2.4.688.1.4Columnpm10010ulhMondownRmonUnicastCounterClientOutputOverloadPortnread-onlycurrentUnicast Counter Overload :This OID when set indicates a Unicast counter overload on client port
1.3.6.1.4.1.20044.80.11.2.4.720Tablepm10010ulhMondownRmonNonunicastCounterClientOutputTablenot-accessiblecurrentList of pm10010ulhMondownRmonNonunicastCounterClientOutput Article
1.3.6.1.4.1.20044.80.11.2.4.720.1Rowpm10010ulhMondownRmonNonunicastCounterClientOutputEntrynot-accessiblecurrentRow definition for the pm10010ulhMondownRmonNonunicastCounterClientOutput table
1.3.6.1.4.1.20044.80.11.2.4.720.1.1Columnpm10010ulhMondownRmonNonunicastCounterClientOutputIndexread-onlycurrentIndex definition for the pm10010ulhMondownRmonNonunicastCounterClientOutput table
1.3.6.1.4.1.20044.80.11.2.4.720.1.2Columnpm10010ulhMondownRmonNonunicastCounterClientOutputValuePortnread-onlycurrentClient Output Non Unicast Packets :This counter is increased each time a Non-Unicast packet is transmitted on the client port <Help> This counter gives the num…
1.3.6.1.4.1.20044.80.11.2.4.720.1.3Columnpm10010ulhMondownRmonNonunicastCounterClientOutputErrorPortnread-onlycurrentNon Unicast Counter Error :This OID when set indicates the Non-Unicast counter value is invalid on client port
1.3.6.1.4.1.20044.80.11.2.4.720.1.4Columnpm10010ulhMondownRmonNonunicastCounterClientOutputOverloadPortnread-onlycurrentNon Unicast Counter Overload :This OID when set indicates a Non-Unicast counter overload on client port
1.3.6.1.4.1.20044.80.11.5Nodepm10010ulhMonPerfOther
1.3.6.1.4.1.20044.80.11.5.1Nodepm10010ulhMonPerfSync
1.3.6.1.4.1.20044.80.11.5.1.257Scalarpm10010ulhPerfEnableread-writecurrentPerf. Mon. Enable :This OID enables the Performance Monitoring application
1.3.6.1.4.1.20044.80.11.5.1.259Scalarpm10010ulhPerf15minSyncread-writecurrentPerf. Mon. 15-min sync. :This OID must be used in external synchronisation mode only to send a 15-min synchronisation command
1.3.6.1.4.1.20044.80.11.5.1.260Scalarpm10010ulhPerf24hSyncread-writecurrentPerf. Mon. 24-hours sync. :This OID must be used in external synchronisation mode only to send a 24-hours synchronisation command
1.3.6.1.4.1.20044.80.11.5.2Nodepm10010ulhMonPerfTimeStamp
1.3.6.1.4.1.20044.80.11.5.2.1Scalarpm10010ulhPerf15MinShortread-writecurrent15-min period is short :This OID indicates that the 15-min period lasts less than 890 seconds
1.3.6.1.4.1.20044.80.11.5.2.2Scalarpm10010ulhPerf15MinLongread-writecurrent15-min period is long :This OID indicates that the 15-min period lasts more than 910 seconds
1.3.6.1.4.1.20044.80.11.5.2.5Scalarpm10010ulhPerf24HoursShortread-writecurrent24-hours period is short :This OID indicates that 24-hours period lasts less than 86390 seconds
1.3.6.1.4.1.20044.80.11.5.2.6Scalarpm10010ulhPerf24HoursLongread-writecurrent24-hours period is long :This OID indicates that 24-hours period lasts more than 86410 seconds
1.3.6.1.4.1.20044.80.11.5.2.7Scalarpm10010ulhPerfCurrent15MinElapsedTimeread-writecurrentCurrent 15min period Elapsed Time :This OID gives the number of seconds elapsed in the current 15-minutes period
1.3.6.1.4.1.20044.80.11.5.2.8Scalarpm10010ulhPerfCurrent24HoursElapsedTimeread-writecurrentCurrent 24hours period Elapsed Time :This OID gives the number of seconds elapsed in the current 24-hours period
1.3.6.1.4.1.20044.80.11.6Nodepm10010ulhMonPerfClient
1.3.6.1.4.1.20044.80.11.6.16Tablepm10010ulhPerfTelecomInputClientCurrent15StatTablenot-accessiblecurrentList of pm10010ulhPerfTelecomInputClientCurrent15Stat Article
1.3.6.1.4.1.20044.80.11.6.16.1Rowpm10010ulhPerfTelecomInputClientCurrent15StatEntrynot-accessiblecurrentRow definition for the pm10010ulhPerfTelecomInputClientCurrent15Stat table
1.3.6.1.4.1.20044.80.11.6.16.1.1Columnpm10010ulhPerfTelecomInputClientCurrent15StatIndexread-onlycurrentIndex definition for the pm10010ulhPerfTelecomInputClientCurrent15Stat table
1.3.6.1.4.1.20044.80.11.6.16.1.2Columnpm10010ulhPerfTelecomInputClientCurrent15StatInvCvPortnread-onlycurrentCurrent 15-min EBC counter inv. :This OID indicates that the current 15-min Coding Violation counter is invalid
1.3.6.1.4.1.20044.80.11.6.16.1.3Columnpm10010ulhPerfTelecomInputClientCurrent15StatCvValuePortnread-onlycurrentCurrent 15-min EBC counter :This OID gives the current 15-min Coding Violation counter value
1.3.6.1.4.1.20044.80.11.6.16.1.4Columnpm10010ulhPerfTelecomInputClientCurrent15StatInvEsPortnread-onlycurrentCurrent 15-min ES counter inv. :This OID indicates that the current 15-min Errored Second counter is invalid
1.3.6.1.4.1.20044.80.11.6.16.1.5Columnpm10010ulhPerfTelecomInputClientCurrent15StatEsValuePortnread-onlycurrentCurrent 15-min ES counter :This OID gives the current 15-min Errored Second counter value
1.3.6.1.4.1.20044.80.11.6.16.1.6Columnpm10010ulhPerfTelecomInputClientCurrent15StatInvSesPortnread-onlycurrentCurrent 15-min SES counter inv. :This OID indicates that the current 15-min severely Errored Second counter is invalid
1.3.6.1.4.1.20044.80.11.6.16.1.7Columnpm10010ulhPerfTelecomInputClientCurrent15StatSesValuePortnread-onlycurrentCurrent 15-min SES counter :This OID gives the current 15-min severely Errored Second counter value
1.3.6.1.4.1.20044.80.11.6.16.1.8Columnpm10010ulhPerfTelecomInputClientCurrent15StatInvSefsPortnread-onlycurrentCurrent 15-min SEFS counter inv. :This OID indicates that the current 15-min severely Errored Framing Second counter is invalid
1.3.6.1.4.1.20044.80.11.6.16.1.9Columnpm10010ulhPerfTelecomInputClientCurrent15StatSefsValuePortnread-onlycurrentCurrent 15-min SEFS counter :This OID gives the current 15-min severely Errored Framing Second counter value
1.3.6.1.4.1.20044.80.11.6.16.1.10Columnpm10010ulhPerfTelecomInputClientCurrent15StatInvUasPortnread-onlycurrentCurrent 15-min UAS counter inv. :This OID indicates that the current 15-min UnAvailable Second counter is invalid
1.3.6.1.4.1.20044.80.11.6.16.1.11Columnpm10010ulhPerfTelecomInputClientCurrent15StatUasValuePortnread-onlycurrentCurrent 15-min UAS counter :This OID gives the current 15-min UnAvailable Second counter value
1.3.6.1.4.1.20044.80.11.6.48Tablepm10010ulhPerfTelecomInputClientPast15StatHistoryPort1Tablenot-accessiblecurrentList of pm10010ulhPerfTelecomInputClientPast15StatHistory Article
1.3.6.1.4.1.20044.80.11.6.48.1Rowpm10010ulhPerfTelecomInputClientPast15StatHistoryPort1Entrynot-accessiblecurrentRow definition for the pm10010ulhPerfTelecomInputClientPast15StatHistory table
1.3.6.1.4.1.20044.80.11.6.48.1.1Columnpm10010ulhPerfTelecomInputClientPast15StatHistoryPort1Indexread-onlycurrentIndex definition for the pm10010ulhPerfTelecomInputClientPast15StatHistory table
1.3.6.1.4.1.20044.80.11.6.48.1.2Columnpm10010ulhPerfTelecomInputClientPast15StatHistoryInvCvPort1read-onlycurrentPrevious 15-min EBC counter inv. :This OID indicates that the previous 15-min Coding Violation counter is invalid
1.3.6.1.4.1.20044.80.11.6.48.1.3Columnpm10010ulhPerfTelecomInputClientPast15StatHistoryCvValuePort1read-onlycurrentPrevious 15-min EBC counter :This OID gives the previous 15-min Coding Violation counter value
1.3.6.1.4.1.20044.80.11.6.48.1.4Columnpm10010ulhPerfTelecomInputClientPast15StatHistoryInvEsPort1read-onlycurrentPrevious 15-min ES counter inv. :This OID indicates that the previous 15-min Errored Second counter is invalid
1.3.6.1.4.1.20044.80.11.6.48.1.5Columnpm10010ulhPerfTelecomInputClientPast15StatHistoryEsValuePort1read-onlycurrentPrevious 15-min ES counter :This OID gives the previous 15-min Errored Second counter value
1.3.6.1.4.1.20044.80.11.6.48.1.6Columnpm10010ulhPerfTelecomInputClientPast15StatHistoryInvSesPort1read-onlycurrentPrevious 15-min SES counter inv. :This OID indicates that the previous 15-min severely Errored Second counter is invalid
1.3.6.1.4.1.20044.80.11.6.48.1.7Columnpm10010ulhPerfTelecomInputClientPast15StatHistorySesValuePort1read-onlycurrentPrevious 15-min SES counter :This OID gives the previous 15-min severely Errored Second counter value
1.3.6.1.4.1.20044.80.11.6.48.1.8Columnpm10010ulhPerfTelecomInputClientPast15StatHistoryInvSefsPort1read-onlycurrentPrevious 15-min SEFS counter inv. :This OID indicates that the previous 15-min severely Errored Framing Second counter is invalid
1.3.6.1.4.1.20044.80.11.6.48.1.9Columnpm10010ulhPerfTelecomInputClientPast15StatHistorySefsValuePort1read-onlycurrentPrevious 15-min SEFS counter :This OID gives the previous 15-min severely Errored Framing Second counter value
1.3.6.1.4.1.20044.80.11.6.48.1.10Columnpm10010ulhPerfTelecomInputClientPast15StatHistoryInvUasPort1read-onlycurrentPrevious 15-min UAS counter inv. :This OID indicates that the previous 15-min UnAvailable Second counter is invalid
1.3.6.1.4.1.20044.80.11.6.48.1.11Columnpm10010ulhPerfTelecomInputClientPast15StatHistoryUasValuePort1read-onlycurrentPrevious 15-min UAS counter :This OID gives the previous 15-min UnAvailable Second counter value
1.3.6.1.4.1.20044.80.11.6.80Tablepm10010ulhPerfTelecomInputClientCurrent24StatTablenot-accessiblecurrentList of pm10010ulhPerfTelecomInputClientCurrent24Stat Article
1.3.6.1.4.1.20044.80.11.6.80.1Rowpm10010ulhPerfTelecomInputClientCurrent24StatEntrynot-accessiblecurrentRow definition for the pm10010ulhPerfTelecomInputClientCurrent24Stat table
1.3.6.1.4.1.20044.80.11.6.80.1.1Columnpm10010ulhPerfTelecomInputClientCurrent24StatIndexread-onlycurrentIndex definition for the pm10010ulhPerfTelecomInputClientCurrent24Stat table
1.3.6.1.4.1.20044.80.11.6.80.1.2Columnpm10010ulhPerfTelecomInputClientCurrent24StatInvCvPortnread-onlycurrentCurrent 24-hours EBC counter inv. :This OID indicates that the current 24-hours Coding Violation counter is invalid
1.3.6.1.4.1.20044.80.11.6.80.1.3Columnpm10010ulhPerfTelecomInputClientCurrent24StatCvValuePortnread-onlycurrentCurrent 24-hours EBC counter :This OID gives the current 24-hours Coding Violation counter value
1.3.6.1.4.1.20044.80.11.6.80.1.4Columnpm10010ulhPerfTelecomInputClientCurrent24StatInvEsPortnread-onlycurrentCurrent 24-hours ES counter inv. :This OID indicates that the current 24-hours Errored Second counter is invalid
1.3.6.1.4.1.20044.80.11.6.80.1.5Columnpm10010ulhPerfTelecomInputClientCurrent24StatEsValuePortnread-onlycurrentCurrent 24-hours ES counter :This OID gives the current 24-hours Errored Second counter value
1.3.6.1.4.1.20044.80.11.6.80.1.6Columnpm10010ulhPerfTelecomInputClientCurrent24StatInvSesPortnread-onlycurrentCurrent 24-hours SES counter inv. :This OID indicates that the current 24-hours severely Errored Second counter is invalid
1.3.6.1.4.1.20044.80.11.6.80.1.7Columnpm10010ulhPerfTelecomInputClientCurrent24StatSesValuePortnread-onlycurrentCurrent 24-hours SES counter :This OID gives the current 24-hours severely Errored Second counter value
1.3.6.1.4.1.20044.80.11.6.80.1.8Columnpm10010ulhPerfTelecomInputClientCurrent24StatInvSefsPortnread-onlycurrentCurrent 24-hours SEFS counter inv. :This OID indicates that the current 24-hours severely Errored Framing Second counter is invalid
1.3.6.1.4.1.20044.80.11.6.80.1.9Columnpm10010ulhPerfTelecomInputClientCurrent24StatSefsValuePortnread-onlycurrentCurrent 24-hours SEFS counter :This OID gives the current 24-hours severely Errored Framing Second counter value
1.3.6.1.4.1.20044.80.11.6.80.1.10Columnpm10010ulhPerfTelecomInputClientCurrent24StatInvUasPortnread-onlycurrentCurrent 24-hours UAS counter inv. :This OID indicates that the current 24-hours UnAvailable Second counter is invalid
1.3.6.1.4.1.20044.80.11.6.80.1.11Columnpm10010ulhPerfTelecomInputClientCurrent24StatUasValuePortnread-onlycurrentCurrent 24-hours UAS counter :This OID gives the current 24-hours UnAvailable Second counter value
1.3.6.1.4.1.20044.80.11.6.112Tablepm10010ulhPerfTelecomInputClientPast24StatHistoryPort1Tablenot-accessiblecurrentList of pm10010ulhPerfTelecomInputClientPast24StatHistory Article
1.3.6.1.4.1.20044.80.11.6.112.1Rowpm10010ulhPerfTelecomInputClientPast24StatHistoryPort1Entrynot-accessiblecurrentRow definition for the pm10010ulhPerfTelecomInputClientPast24StatHistory table
1.3.6.1.4.1.20044.80.11.6.112.1.1Columnpm10010ulhPerfTelecomInputClientPast24StatHistoryPort1Indexread-onlycurrentIndex definition for the pm10010ulhPerfTelecomInputClientPast24StatHistory table
1.3.6.1.4.1.20044.80.11.6.112.1.2Columnpm10010ulhPerfTelecomInputClientPast24StatHistoryInvCvPort1read-onlycurrentPrevious 24-hours EBC counter inv. :This OID indicates that the previous 24-hours Coding Violation counter is invalid
1.3.6.1.4.1.20044.80.11.6.112.1.3Columnpm10010ulhPerfTelecomInputClientPast24StatHistoryCvValuePort1read-onlycurrentPrevious 24-hours EBC counter :This OID gives the previous 24-hours Coding Violation counter value
1.3.6.1.4.1.20044.80.11.6.112.1.4Columnpm10010ulhPerfTelecomInputClientPast24StatHistoryInvEsPort1read-onlycurrentPrevious 24-hours ES counter inv. :This OID indicates that the previous 24-hours Errored Second counter is invalid
1.3.6.1.4.1.20044.80.11.6.112.1.5Columnpm10010ulhPerfTelecomInputClientPast24StatHistoryEsValuePort1read-onlycurrentPrevious 24-hours ES counter :This OID gives the previous 24-hours Errored Second counter value
1.3.6.1.4.1.20044.80.11.6.112.1.6Columnpm10010ulhPerfTelecomInputClientPast24StatHistoryInvSesPort1read-onlycurrentPrevious 24-hours SES counter inv. :This OID indicates that the previous 24-hours severely Errored Second counter is invalid
1.3.6.1.4.1.20044.80.11.6.112.1.7Columnpm10010ulhPerfTelecomInputClientPast24StatHistorySesValuePort1read-onlycurrentPrevious 24-hours SES counter :This OID gives the previous 24-hours severely Errored Second counter value
1.3.6.1.4.1.20044.80.11.6.112.1.8Columnpm10010ulhPerfTelecomInputClientPast24StatHistoryInvSefsPort1read-onlycurrentPrevious 24-hours SEFS counter inv. :This OID indicates that the previous 24-hours severely Errored Framing Second counter is invalid
1.3.6.1.4.1.20044.80.11.6.112.1.9Columnpm10010ulhPerfTelecomInputClientPast24StatHistorySefsValuePort1read-onlycurrentPrevious 24-hours SEFS counter :This OID gives the previous 24-hours severely Errored Framing Second counter value
1.3.6.1.4.1.20044.80.11.6.112.1.10Columnpm10010ulhPerfTelecomInputClientPast24StatHistoryInvUasPort1read-onlycurrentPrevious 24-hours UAS counter inv. :This OID indicates that the previous 24-hours UnAvailable Second counter is invalid
1.3.6.1.4.1.20044.80.11.6.112.1.11Columnpm10010ulhPerfTelecomInputClientPast24StatHistoryUasValuePort1read-onlycurrentPrevious 24-hours UAS counter :This OID gives the previous 24-hours UnAvailable Second counter value
1.3.6.1.4.1.20044.80.11.6.144Tablepm10010ulhPerfTelecomOutputClientCurrent15StatTablenot-accessiblecurrentList of pm10010ulhPerfTelecomOutputClientCurrent15Stat Article
1.3.6.1.4.1.20044.80.11.6.144.1Rowpm10010ulhPerfTelecomOutputClientCurrent15StatEntrynot-accessiblecurrentRow definition for the pm10010ulhPerfTelecomOutputClientCurrent15Stat table
1.3.6.1.4.1.20044.80.11.6.144.1.1Columnpm10010ulhPerfTelecomOutputClientCurrent15StatIndexread-onlycurrentIndex definition for the pm10010ulhPerfTelecomOutputClientCurrent15Stat table
1.3.6.1.4.1.20044.80.11.6.144.1.2Columnpm10010ulhPerfTelecomOutputClientCurrent15StatInvCvPortnread-onlycurrentCurrent 15-min EBC counter inv. :This OID indicates that the current 15-min Coding Violation counter is invalid
1.3.6.1.4.1.20044.80.11.6.144.1.3Columnpm10010ulhPerfTelecomOutputClientCurrent15StatCvValuePortnread-onlycurrentCurrent 15-min EBC counter :This OID gives the current 15-min Coding Violation counter value
1.3.6.1.4.1.20044.80.11.6.144.1.4Columnpm10010ulhPerfTelecomOutputClientCurrent15StatInvEsPortnread-onlycurrentCurrent 15-min ES counter inv. :This OID indicates that the current 15-min Errored Second counter is invalid
1.3.6.1.4.1.20044.80.11.6.144.1.5Columnpm10010ulhPerfTelecomOutputClientCurrent15StatEsValuePortnread-onlycurrentCurrent 15-min ES counter :This OID gives the current 15-min Errored Second counter value
1.3.6.1.4.1.20044.80.11.6.144.1.6Columnpm10010ulhPerfTelecomOutputClientCurrent15StatInvSesPortnread-onlycurrentCurrent 15-min SES counter inv. :This OID indicates that the current 15-min severely Errored Second counter is invalid
1.3.6.1.4.1.20044.80.11.6.144.1.7Columnpm10010ulhPerfTelecomOutputClientCurrent15StatSesValuePortnread-onlycurrentCurrent 15-min SES counter :This OID gives the current 15-min severely Errored Second counter value
1.3.6.1.4.1.20044.80.11.6.144.1.8Columnpm10010ulhPerfTelecomOutputClientCurrent15StatInvSefsPortnread-onlycurrentCurrent 15-min SEFS counter inv. :This OID indicates that the current 15-min severely Errored Framing Second counter is invalid
1.3.6.1.4.1.20044.80.11.6.144.1.9Columnpm10010ulhPerfTelecomOutputClientCurrent15StatSefsValuePortnread-onlycurrentCurrent 15-min SEFS counter :This OID gives the current 15-min severely Errored Framing Second counter value
1.3.6.1.4.1.20044.80.11.6.144.1.10Columnpm10010ulhPerfTelecomOutputClientCurrent15StatInvUasPortnread-onlycurrentCurrent 15-min UAS counter inv. :This OID indicates that the current 15-min UnAvailable Second counter is invalid
1.3.6.1.4.1.20044.80.11.6.144.1.11Columnpm10010ulhPerfTelecomOutputClientCurrent15StatUasValuePortnread-onlycurrentCurrent 15-min UAS counter :This OID gives the current 15-min UnAvailable Second counter value
1.3.6.1.4.1.20044.80.11.6.176Tablepm10010ulhPerfTelecomOutputClientPast15StatHistoryPort1Tablenot-accessiblecurrentList of pm10010ulhPerfTelecomOutputClientPast15StatHistory Article
1.3.6.1.4.1.20044.80.11.6.176.1Rowpm10010ulhPerfTelecomOutputClientPast15StatHistoryPort1Entrynot-accessiblecurrentRow definition for the pm10010ulhPerfTelecomOutputClientPast15StatHistory table
1.3.6.1.4.1.20044.80.11.6.176.1.1Columnpm10010ulhPerfTelecomOutputClientPast15StatHistoryPort1Indexread-onlycurrentIndex definition for the pm10010ulhPerfTelecomOutputClientPast15StatHistory table
1.3.6.1.4.1.20044.80.11.6.176.1.2Columnpm10010ulhPerfTelecomOutputClientPast15StatHistoryInvCvPort1read-onlycurrentPrevious 15-min EBC counter inv. :This OID indicates that the previous 15-min Coding Violation counter is invalid
1.3.6.1.4.1.20044.80.11.6.176.1.3Columnpm10010ulhPerfTelecomOutputClientPast15StatHistoryCvValuePort1read-onlycurrentPrevious 15-min EBC counter :This OID gives the previous 15-min Coding Violation counter value
1.3.6.1.4.1.20044.80.11.6.176.1.4Columnpm10010ulhPerfTelecomOutputClientPast15StatHistoryInvEsPort1read-onlycurrentPrevious 15-min ES counter inv. :This OID indicates that the previous 15-min Errored Second counter is invalid
1.3.6.1.4.1.20044.80.11.6.176.1.5Columnpm10010ulhPerfTelecomOutputClientPast15StatHistoryEsValuePort1read-onlycurrentPrevious 15-min ES counter :This OID gives the previous 15-min Errored Second counter value
1.3.6.1.4.1.20044.80.11.6.176.1.6Columnpm10010ulhPerfTelecomOutputClientPast15StatHistoryInvSesPort1read-onlycurrentPrevious 15-min SES counter inv. :This OID indicates that the previous 15-min severely Errored Second counter is invalid
1.3.6.1.4.1.20044.80.11.6.176.1.7Columnpm10010ulhPerfTelecomOutputClientPast15StatHistorySesValuePort1read-onlycurrentPrevious 15-min SES counter :This OID gives the previous 15-min severely Errored Second counter value
1.3.6.1.4.1.20044.80.11.6.176.1.8Columnpm10010ulhPerfTelecomOutputClientPast15StatHistoryInvSefsPort1read-onlycurrentPrevious 15-min SEFS counter inv. :This OID indicates that the previous 15-min severely Errored Framing Second counter is invalid
1.3.6.1.4.1.20044.80.11.6.176.1.9Columnpm10010ulhPerfTelecomOutputClientPast15StatHistorySefsValuePort1read-onlycurrentPrevious 15-min SEFS counter :This OID gives the previous 15-min severely Errored Framing Second counter value
1.3.6.1.4.1.20044.80.11.6.176.1.10Columnpm10010ulhPerfTelecomOutputClientPast15StatHistoryInvUasPort1read-onlycurrentPrevious 15-min UAS counter inv. :This OID indicates that the previous 15-min UnAvailable Second counter is invalid
1.3.6.1.4.1.20044.80.11.6.176.1.11Columnpm10010ulhPerfTelecomOutputClientPast15StatHistoryUasValuePort1read-onlycurrentPrevious 15-min UAS counter :This OID gives the previous 15-min UnAvailable Second counter value
1.3.6.1.4.1.20044.80.11.6.208Tablepm10010ulhPerfTelecomOutputClientCurrent24StatTablenot-accessiblecurrentList of pm10010ulhPerfTelecomOutputClientCurrent24Stat Article
1.3.6.1.4.1.20044.80.11.6.208.1Rowpm10010ulhPerfTelecomOutputClientCurrent24StatEntrynot-accessiblecurrentRow definition for the pm10010ulhPerfTelecomOutputClientCurrent24Stat table
1.3.6.1.4.1.20044.80.11.6.208.1.1Columnpm10010ulhPerfTelecomOutputClientCurrent24StatIndexread-onlycurrentIndex definition for the pm10010ulhPerfTelecomOutputClientCurrent24Stat table
1.3.6.1.4.1.20044.80.11.6.208.1.2Columnpm10010ulhPerfTelecomOutputClientCurrent24StatInvCvPortnread-onlycurrentCurrent 24-hours EBC counter inv. :This OID indicates that the current 24-hours Coding Violation counter is invalid
1.3.6.1.4.1.20044.80.11.6.208.1.3Columnpm10010ulhPerfTelecomOutputClientCurrent24StatCvValuePortnread-onlycurrentCurrent 24-hours EBC counter :This OID gives the current 24-hours Coding Violation counter value
1.3.6.1.4.1.20044.80.11.6.208.1.4Columnpm10010ulhPerfTelecomOutputClientCurrent24StatInvEsPortnread-onlycurrentCurrent 24-hours ES counter inv. :This OID indicates that the current 24-hours Errored Second counter is invalid
1.3.6.1.4.1.20044.80.11.6.208.1.5Columnpm10010ulhPerfTelecomOutputClientCurrent24StatEsValuePortnread-onlycurrentCurrent 24-hours ES counter :This OID gives the current 24-hours Errored Second counter value
1.3.6.1.4.1.20044.80.11.6.208.1.6Columnpm10010ulhPerfTelecomOutputClientCurrent24StatInvSesPortnread-onlycurrentCurrent 24-hours SES counter inv. :This OID indicates that the current 24-hours severely Errored Second counter is invalid
1.3.6.1.4.1.20044.80.11.6.208.1.7Columnpm10010ulhPerfTelecomOutputClientCurrent24StatSesValuePortnread-onlycurrentCurrent 24-hours SES counter :This OID gives the current 24-hours severely Errored Second counter value
1.3.6.1.4.1.20044.80.11.6.208.1.8Columnpm10010ulhPerfTelecomOutputClientCurrent24StatInvSefsPortnread-onlycurrentCurrent 24-hours SEFS counter inv. :This OID indicates that the current 24-hours severely Errored Framing Second counter is invalid
1.3.6.1.4.1.20044.80.11.6.208.1.9Columnpm10010ulhPerfTelecomOutputClientCurrent24StatSefsValuePortnread-onlycurrentCurrent 24-hours SEFS counter :This OID gives the current 24-hours severely Errored Framing Second counter value
1.3.6.1.4.1.20044.80.11.6.208.1.10Columnpm10010ulhPerfTelecomOutputClientCurrent24StatInvUasPortnread-onlycurrentCurrent 24-hours UAS counter inv. :This OID indicates that the current 24-hours UnAvailable Second counter is invalid
1.3.6.1.4.1.20044.80.11.6.208.1.11Columnpm10010ulhPerfTelecomOutputClientCurrent24StatUasValuePortnread-onlycurrentCurrent 24-hours UAS counter :This OID gives the current 24-hours UnAvailable Second counter value
1.3.6.1.4.1.20044.80.11.6.240Tablepm10010ulhPerfTelecomOutputClientPast24StatHistoryPort1Tablenot-accessiblecurrentList of pm10010ulhPerfTelecomOutputClientPast24StatHistory Article
1.3.6.1.4.1.20044.80.11.6.240.1Rowpm10010ulhPerfTelecomOutputClientPast24StatHistoryPort1Entrynot-accessiblecurrentRow definition for the pm10010ulhPerfTelecomOutputClientPast24StatHistory table
1.3.6.1.4.1.20044.80.11.6.240.1.1Columnpm10010ulhPerfTelecomOutputClientPast24StatHistoryPort1Indexread-onlycurrentIndex definition for the pm10010ulhPerfTelecomOutputClientPast24StatHistory table
1.3.6.1.4.1.20044.80.11.6.240.1.2Columnpm10010ulhPerfTelecomOutputClientPast24StatHistoryInvCvPort1read-onlycurrentPrevious 24-hours EBC counter inv. :This OID indicates that the previous 24-hours Coding Violation counter is invalid
1.3.6.1.4.1.20044.80.11.6.240.1.3Columnpm10010ulhPerfTelecomOutputClientPast24StatHistoryCvValuePort1read-onlycurrentPrevious 24-hours EBC counter :This OID gives the previous 24-hours Coding Violation counter value
1.3.6.1.4.1.20044.80.11.6.240.1.4Columnpm10010ulhPerfTelecomOutputClientPast24StatHistoryInvEsPort1read-onlycurrentPrevious 24-hours ES counter inv. :This OID indicates that the previous 24-hours Errored Second counter is invalid
1.3.6.1.4.1.20044.80.11.6.240.1.5Columnpm10010ulhPerfTelecomOutputClientPast24StatHistoryEsValuePort1read-onlycurrentPrevious 24-hours ES counter :This OID gives the previous 24-hours Errored Second counter value
1.3.6.1.4.1.20044.80.11.6.240.1.6Columnpm10010ulhPerfTelecomOutputClientPast24StatHistoryInvSesPort1read-onlycurrentPrevious 24-hours SES counter inv. :This OID indicates that the previous 24-hours severely Errored Second counter is invalid
1.3.6.1.4.1.20044.80.11.6.240.1.7Columnpm10010ulhPerfTelecomOutputClientPast24StatHistorySesValuePort1read-onlycurrentPrevious 24-hours SES counter :This OID gives the previous 24-hours severely Errored Second counter value
1.3.6.1.4.1.20044.80.11.6.240.1.8Columnpm10010ulhPerfTelecomOutputClientPast24StatHistoryInvSefsPort1read-onlycurrentPrevious 24-hours SEFS counter inv. :This OID indicates that the previous 24-hours severely Errored Framing Second counter is invalid
1.3.6.1.4.1.20044.80.11.6.240.1.9Columnpm10010ulhPerfTelecomOutputClientPast24StatHistorySefsValuePort1read-onlycurrentPrevious 24-hours SEFS counter :This OID gives the previous 24-hours severely Errored Framing Second counter value
1.3.6.1.4.1.20044.80.11.6.240.1.10Columnpm10010ulhPerfTelecomOutputClientPast24StatHistoryInvUasPort1read-onlycurrentPrevious 24-hours UAS counter inv. :This OID indicates that the previous 24-hours UnAvailable Second counter is invalid
1.3.6.1.4.1.20044.80.11.6.240.1.11Columnpm10010ulhPerfTelecomOutputClientPast24StatHistoryUasValuePort1read-onlycurrentPrevious 24-hours UAS counter :This OID gives the previous 24-hours UnAvailable Second counter value
1.3.6.1.4.1.20044.80.11.6.848Tablepm10010ulhPerfDatacomClientCurrent15StatTablenot-accessiblecurrentList of pm10010ulhPerfDatacomClientCurrent15Stat Article
1.3.6.1.4.1.20044.80.11.6.848.1Rowpm10010ulhPerfDatacomClientCurrent15StatEntrynot-accessiblecurrentRow definition for the pm10010ulhPerfDatacomClientCurrent15Stat table
1.3.6.1.4.1.20044.80.11.6.848.1.1Columnpm10010ulhPerfDatacomClientCurrent15StatIndexread-onlycurrentIndex definition for the pm10010ulhPerfDatacomClientCurrent15Stat table
1.3.6.1.4.1.20044.80.11.6.848.1.4Columnpm10010ulhperfdatacomclientCurrent15StatInCrcCountInvPortnread-onlycurrentClient Current 15-min Input CRC counter inv. :This OID indicates that the current 15-min Input CRC counter is invalid
1.3.6.1.4.1.20044.80.11.6.848.1.5Columnpm10010ulhperfdatacomclientCurrent15StatInCrcCountPortnread-onlycurrentClient Current 15-min Input CRC counter :This OID gives the current 15-min Input CRC counter value
1.3.6.1.4.1.20044.80.11.6.848.1.6Columnpm10010ulhperfdatacomclientCurrent15StatInPacketCountInvPortnread-onlycurrentClient Current 15-min Input Packet counter inv. :This OID indicates that the current 15-min Input Packet counter is invalid
1.3.6.1.4.1.20044.80.11.6.848.1.7Columnpm10010ulhperfdatacomclientCurrent15StatInPacketCountPortnread-onlycurrentClient Current 15-min Input Packet counter :This OID gives the current 15-min Input Packet counter value
1.3.6.1.4.1.20044.80.11.6.848.1.28Columnpm10010ulhperfdatacomclientCurrent15StatOutCrcCountInvPortnread-onlycurrentClient Current 15-min Output CRC counter inv. :This OID indicates that the current 15-min Output CRC counter is invalid
1.3.6.1.4.1.20044.80.11.6.848.1.29Columnpm10010ulhperfdatacomclientCurrent15StatOutCrcCountPortnread-onlycurrentClient Current 15-min Output CRC counter :This OID gives the current 15-min Output CRC counter value
1.3.6.1.4.1.20044.80.11.6.848.1.30Columnpm10010ulhperfdatacomclientCurrent15StatOutPacketCountInvPortnread-onlycurrentClient Current 15-min Output Packet counter inv. :This OID indicates that the current 15-min Output Packets counter is invalid
1.3.6.1.4.1.20044.80.11.6.848.1.31Columnpm10010ulhperfdatacomclientCurrent15StatOutPacketCountPortnread-onlycurrentClient Current 15-min Output Packet counter :This OID gives the current 15-min Output Packets counter value
1.3.6.1.4.1.20044.80.11.6.880Tablepm10010ulhPerfDatacomClientPast15StatHistoryPort1Tablenot-accessiblecurrentList of pm10010ulhPerfDatacomClientPast15StatHistory Article
1.3.6.1.4.1.20044.80.11.6.880.1Rowpm10010ulhPerfDatacomClientPast15StatHistoryPort1Entrynot-accessiblecurrentRow definition for the pm10010ulhPerfDatacomClientPast15StatHistory table
1.3.6.1.4.1.20044.80.11.6.880.1.1Columnpm10010ulhPerfDatacomClientPast15StatHistoryPort1Indexread-onlycurrentIndex definition for the pm10010ulhPerfDatacomClientPast15StatHistory table
1.3.6.1.4.1.20044.80.11.6.880.1.4Columnpm10010ulhperfdatacomclientPast15StatInCrcCountInvPort1read-onlycurrentClient Past 15-min Input CRC counter inv. :This OID indicates that the past 15-min Input CRC counter is invalid
1.3.6.1.4.1.20044.80.11.6.880.1.5Columnpm10010ulhperfdatacomclientPast15StatInCrcCountPort1read-onlycurrentClient Past 15-min Input CRC counter :This OID gives the past 15-min Input CRC counter value
1.3.6.1.4.1.20044.80.11.6.880.1.6Columnpm10010ulhperfdatacomclientPast15StatInPacketCountInvPort1read-onlycurrentClient Past 15-min Input Packet counter inv. :This OID indicates that the past 15-min Input Packet counter is invalid
1.3.6.1.4.1.20044.80.11.6.880.1.7Columnpm10010ulhperfdatacomclientPast15StatInPacketCountPort1read-onlycurrentClient Past 15-min Input Packet counter :This OID gives the past 15-min Input Packet counter value
1.3.6.1.4.1.20044.80.11.6.880.1.28Columnpm10010ulhperfdatacomclientPast15StatOutCrcCountInvPort1read-onlycurrentClient Past 15-min Output CRC counter inv. :This OID indicates that the past 15-min Output CRC counter is invalid
1.3.6.1.4.1.20044.80.11.6.880.1.29Columnpm10010ulhperfdatacomclientPast15StatOutCrcCountPort1read-onlycurrentClient Past 15-min Output CRC counter :This OID gives the past 15-min Output CRC counter value
1.3.6.1.4.1.20044.80.11.6.880.1.30Columnpm10010ulhperfdatacomclientPast15StatOutPacketCountInvPort1read-onlycurrentClient Past 15-min Output Packet counter inv. :This OID indicates that the past 15-min Output Packets counter is invalid
1.3.6.1.4.1.20044.80.11.6.880.1.31Columnpm10010ulhperfdatacomclientPast15StatOutPacketCountPort1read-onlycurrentClient Past 15-min Output Packet counter :This OID gives the past 15-min Output Packets counter value
1.3.6.1.4.1.20044.80.11.6.912Tablepm10010ulhPerfDatacomClientCurrent24StatTablenot-accessiblecurrentList of pm10010ulhPerfDatacomClientCurrent24Stat Article
1.3.6.1.4.1.20044.80.11.6.912.1Rowpm10010ulhPerfDatacomClientCurrent24StatEntrynot-accessiblecurrentRow definition for the pm10010ulhPerfDatacomClientCurrent24Stat table
1.3.6.1.4.1.20044.80.11.6.912.1.1Columnpm10010ulhPerfDatacomClientCurrent24StatIndexread-onlycurrentIndex definition for the pm10010ulhPerfDatacomClientCurrent24Stat table
1.3.6.1.4.1.20044.80.11.6.912.1.4Columnpm10010ulhperfdatacomclientCurrent24StatInCrcCountInvPortnread-onlycurrentClient Current 24-hours Input CRC counter inv. :This OID indicates that the current 24-hours Input CRC counter is invalid
1.3.6.1.4.1.20044.80.11.6.912.1.5Columnpm10010ulhperfdatacomclientCurrent24StatInCrcCountPortnread-onlycurrentClient Current 24-hours Input CRC counter :This OID gives the current 24-hours Input CRC counter value
1.3.6.1.4.1.20044.80.11.6.912.1.6Columnpm10010ulhperfdatacomclientCurrent24StatInPacketCountInvPortnread-onlycurrentClient Current 24-hours Input Packet counter inv. :This OID indicates that the current 24-hours Input Packet counter is invalid
1.3.6.1.4.1.20044.80.11.6.912.1.7Columnpm10010ulhperfdatacomclientCurrent24StatInPacketCountPortnread-onlycurrentClient Current 24-hours Input Packet counter :This OID gives the current 24-hours Input Packet counter value
1.3.6.1.4.1.20044.80.11.6.912.1.28Columnpm10010ulhperfdatacomclientCurrent24StatOutCrcCountInvPortnread-onlycurrentClient Current 24-hours Output CRC counter inv. :This OID indicates that the current 24-hours Output CRC counter is invalid
1.3.6.1.4.1.20044.80.11.6.912.1.29Columnpm10010ulhperfdatacomclientCurrent24StatOutCrcCountPortnread-onlycurrentClient Current 24-hours Output CRC counter :This OID gives the current 24-hours Output CRC counter value
1.3.6.1.4.1.20044.80.11.6.912.1.30Columnpm10010ulhperfdatacomclientCurrent24StatOutPacketCountInvPortnread-onlycurrentClient Current 24-hours Output Packet counter inv. :This OID indicates that the current 24-hours Output Packets counter is invalid
1.3.6.1.4.1.20044.80.11.6.912.1.31Columnpm10010ulhperfdatacomclientCurrent24StatOutPacketCountPortnread-onlycurrentClient Current 24-hours Output Packet counter :This OID gives the current 24-hours Output Packets counter value
1.3.6.1.4.1.20044.80.11.6.944Tablepm10010ulhPerfDatacomClientPast24StatHistoryPort1Tablenot-accessiblecurrentList of pm10010ulhPerfDatacomClientPast24StatHistory Article
1.3.6.1.4.1.20044.80.11.6.944.1Rowpm10010ulhPerfDatacomClientPast24StatHistoryPort1Entrynot-accessiblecurrentRow definition for the pm10010ulhPerfDatacomClientPast24StatHistory table
1.3.6.1.4.1.20044.80.11.6.944.1.1Columnpm10010ulhPerfDatacomClientPast24StatHistoryPort1Indexread-onlycurrentIndex definition for the pm10010ulhPerfDatacomClientPast24StatHistory table
1.3.6.1.4.1.20044.80.11.6.944.1.4Columnpm10010ulhperfdatacomclientPast24StatInCrcCountInvPort1read-onlycurrentClient Past 24-hours Input CRC counter inv. :This OID indicates that the past 24-hours Input CRC counter is invalid
1.3.6.1.4.1.20044.80.11.6.944.1.5Columnpm10010ulhperfdatacomclientPast24StatInCrcCountPort1read-onlycurrentClient Past 24-hours Input CRC counter :This OID gives the past 24-hours Input CRC counter value
1.3.6.1.4.1.20044.80.11.6.944.1.6Columnpm10010ulhperfdatacomclientPast24StatInPacketCountInvPort1read-onlycurrentClient Past 24-hours Input Packet counter inv. :This OID indicates that the past 24-hours Input Packet counter is invalid
1.3.6.1.4.1.20044.80.11.6.944.1.7Columnpm10010ulhperfdatacomclientPast24StatInPacketCountPort1read-onlycurrentClient Past 24-hours Input Packet counter :This OID gives the past 24-hours Input Packet counter value
1.3.6.1.4.1.20044.80.11.6.944.1.28Columnpm10010ulhperfdatacomclientPast24StatOutCrcCountInvPort1read-onlycurrentClient Past 24-hours Output CRC counter inv. :This OID indicates that the past 24-hours Output CRC counter is invalid
1.3.6.1.4.1.20044.80.11.6.944.1.29Columnpm10010ulhperfdatacomclientPast24StatOutCrcCountPort1read-onlycurrentClient Past 24-hours Output CRC counter :This OID gives the past 24-hours Output CRC counter value
1.3.6.1.4.1.20044.80.11.6.944.1.30Columnpm10010ulhperfdatacomclientPast24StatOutPacketCountInvPort1read-onlycurrentClient Past 24-hours Output Packet counter inv. :This OID indicates that the past 24-hours Output Packets counter is invalid
1.3.6.1.4.1.20044.80.11.6.944.1.31Columnpm10010ulhperfdatacomclientPast24StatOutPacketCountPort1read-onlycurrentClient Past 24-hours Output Packet counter :This OID gives the past 24-hours Output Packets counter value
1.3.6.1.4.1.20044.80.11.7Nodepm10010ulhMonPerfLine
1.3.6.1.4.1.20044.80.11.7.336Tablepm10010ulhPerfTelecomLinePostFecCurrent15StatTablenot-accessiblecurrentList of pm10010ulhPerfTelecomLinePostFecCurrent15Stat Article
1.3.6.1.4.1.20044.80.11.7.336.1Rowpm10010ulhPerfTelecomLinePostFecCurrent15StatEntrynot-accessiblecurrentRow definition for the pm10010ulhPerfTelecomLinePostFecCurrent15Stat table
1.3.6.1.4.1.20044.80.11.7.336.1.1Columnpm10010ulhPerfTelecomLinePostFecCurrent15StatIndexread-onlycurrentIndex definition for the pm10010ulhPerfTelecomLinePostFecCurrent15Stat table
1.3.6.1.4.1.20044.80.11.7.336.1.2Columnpm10010ulhPerfTelecomLinePostFecCurrent15StatInvCvPortnread-onlycurrentCurrent 15-min EBC counter inv. :This OID indicates that the current 15-min Coding Violation counter is invalid
1.3.6.1.4.1.20044.80.11.7.336.1.3Columnpm10010ulhPerfTelecomLinePostFecCurrent15StatCvValuePortnread-onlycurrentCurrent 15-min EBC counter :This OID gives the current 15-min Coding Violation counter value
1.3.6.1.4.1.20044.80.11.7.336.1.4Columnpm10010ulhPerfTelecomLinePostFecCurrent15StatInvEsPortnread-onlycurrentCurrent 15-min ES counter inv. :This OID indicates that the current 15-min Errored Second counter is invalid
1.3.6.1.4.1.20044.80.11.7.336.1.5Columnpm10010ulhPerfTelecomLinePostFecCurrent15StatEsValuePortnread-onlycurrentCurrent 15-min ES counter :This OID gives the current 15-min Errored Second counter value
1.3.6.1.4.1.20044.80.11.7.336.1.6Columnpm10010ulhPerfTelecomLinePostFecCurrent15StatInvSesPortnread-onlycurrentCurrent 15-min SES counter inv. :This OID indicates that the current 15-min severely Errored Second counter is invalid
1.3.6.1.4.1.20044.80.11.7.336.1.7Columnpm10010ulhPerfTelecomLinePostFecCurrent15StatSesValuePortnread-onlycurrentCurrent 15-min SES counter :This OID gives the current 15-min severely Errored Second counter value
1.3.6.1.4.1.20044.80.11.7.336.1.8Columnpm10010ulhPerfTelecomLinePostFecCurrent15StatInvSefsPortnread-onlycurrentCurrent 15-min SEFS counter inv. :This OID indicates that the current 15-min severely Errored Framing Second counter is invalid
1.3.6.1.4.1.20044.80.11.7.336.1.9Columnpm10010ulhPerfTelecomLinePostFecCurrent15StatSefsValuePortnread-onlycurrentCurrent 15-min SEFS counter :This OID gives the current 15-min severely Errored Framing Second counter value
1.3.6.1.4.1.20044.80.11.7.336.1.10Columnpm10010ulhPerfTelecomLinePostFecCurrent15StatInvUasPortnread-onlycurrentCurrent 15-min UAS counter inv. :This OID indicates that the current 15-min UnAvailable Second counter is invalid
1.3.6.1.4.1.20044.80.11.7.336.1.11Columnpm10010ulhPerfTelecomLinePostFecCurrent15StatUasValuePortnread-onlycurrentCurrent 15-min UAS counter :This OID gives the current 15-min UnAvailable Second counter value
1.3.6.1.4.1.20044.80.11.7.337Tablepm10010ulhPerfTelecomLinePostFecPast15StatHistoryPort1Tablenot-accessiblecurrentList of pm10010ulhPerfTelecomLinePostFecPast15StatHistory Article
1.3.6.1.4.1.20044.80.11.7.337.1Rowpm10010ulhPerfTelecomLinePostFecPast15StatHistoryPort1Entrynot-accessiblecurrentRow definition for the pm10010ulhPerfTelecomLinePostFecPast15StatHistory table
1.3.6.1.4.1.20044.80.11.7.337.1.1Columnpm10010ulhPerfTelecomLinePostFecPast15StatHistoryPort1Indexread-onlycurrentIndex definition for the pm10010ulhPerfTelecomLinePostFecPast15StatHistory table
1.3.6.1.4.1.20044.80.11.7.337.1.2Columnpm10010ulhPerfTelecomLinePostFecPast15StatHistoryInvCvPort1read-onlycurrentPrevious 15-min EBC counter inv. :This OID indicates that the previous 15-min Coding Violation counter is invalid
1.3.6.1.4.1.20044.80.11.7.337.1.3Columnpm10010ulhPerfTelecomLinePostFecPast15StatHistoryCvValuePort1read-onlycurrentPrevious 15-min EBC counter :This OID gives the previous 15-min Coding Violation counter value
1.3.6.1.4.1.20044.80.11.7.337.1.4Columnpm10010ulhPerfTelecomLinePostFecPast15StatHistoryInvEsPort1read-onlycurrentPrevious 15-min ES counter inv. :This OID indicates that the previous 15-min Errored Second counter is invalid
1.3.6.1.4.1.20044.80.11.7.337.1.5Columnpm10010ulhPerfTelecomLinePostFecPast15StatHistoryEsValuePort1read-onlycurrentPrevious 15-min ES counter :This OID gives the previous 15-min Errored Second counter value
1.3.6.1.4.1.20044.80.11.7.337.1.6Columnpm10010ulhPerfTelecomLinePostFecPast15StatHistoryInvSesPort1read-onlycurrentPrevious 15-min SES counter inv. :This OID indicates that the previous 15-min severely Errored Second counter is invalid
1.3.6.1.4.1.20044.80.11.7.337.1.7Columnpm10010ulhPerfTelecomLinePostFecPast15StatHistorySesValuePort1read-onlycurrentPrevious 15-min SES counter :This OID gives the previous 15-min severely Errored Second counter value
1.3.6.1.4.1.20044.80.11.7.337.1.8Columnpm10010ulhPerfTelecomLinePostFecPast15StatHistoryInvSefsPort1read-onlycurrentPrevious 15-min SEFS counter inv. :This OID indicates that the previous 15-min severely Errored Framing Second counter is invalid
1.3.6.1.4.1.20044.80.11.7.337.1.9Columnpm10010ulhPerfTelecomLinePostFecPast15StatHistorySefsValuePort1read-onlycurrentPrevious 15-min SEFS counter :This OID gives the previous 15-min severely Errored Framing Second counter value
1.3.6.1.4.1.20044.80.11.7.337.1.10Columnpm10010ulhPerfTelecomLinePostFecPast15StatHistoryInvUasPort1read-onlycurrentPrevious 15-min UAS counter inv. :This OID indicates that the previous 15-min UnAvailable Second counter is invalid
1.3.6.1.4.1.20044.80.11.7.337.1.11Columnpm10010ulhPerfTelecomLinePostFecPast15StatHistoryUasValuePort1read-onlycurrentPrevious 15-min UAS counter :This OID gives the previous 15-min UnAvailable Second counter value
1.3.6.1.4.1.20044.80.11.7.338Tablepm10010ulhPerfTelecomLinePostFecCurrent24StatTablenot-accessiblecurrentList of pm10010ulhPerfTelecomLinePostFecCurrent24Stat Article
1.3.6.1.4.1.20044.80.11.7.338.1Rowpm10010ulhPerfTelecomLinePostFecCurrent24StatEntrynot-accessiblecurrentRow definition for the pm10010ulhPerfTelecomLinePostFecCurrent24Stat table
1.3.6.1.4.1.20044.80.11.7.338.1.1Columnpm10010ulhPerfTelecomLinePostFecCurrent24StatIndexread-onlycurrentIndex definition for the pm10010ulhPerfTelecomLinePostFecCurrent24Stat table
1.3.6.1.4.1.20044.80.11.7.338.1.2Columnpm10010ulhPerfTelecomLinePostFecCurrent24StatInvCvPortnread-onlycurrentCurrent 24-hours EBC counter inv. :This OID indicates that the current 24-hours Coding Violation counter is invalid
1.3.6.1.4.1.20044.80.11.7.338.1.3Columnpm10010ulhPerfTelecomLinePostFecCurrent24StatCvValuePortnread-onlycurrentCurrent 24-hours EBC counter :This OID gives the current 24-hours Coding Violation counter value
1.3.6.1.4.1.20044.80.11.7.338.1.4Columnpm10010ulhPerfTelecomLinePostFecCurrent24StatInvEsPortnread-onlycurrentCurrent 24-hours ES counter inv. :This OID indicates that the current 24-hours Errored Second counter is invalid
1.3.6.1.4.1.20044.80.11.7.338.1.5Columnpm10010ulhPerfTelecomLinePostFecCurrent24StatEsValuePortnread-onlycurrentCurrent 24-hours ES counter :This OID gives the current 24-hours Errored Second counter value
1.3.6.1.4.1.20044.80.11.7.338.1.6Columnpm10010ulhPerfTelecomLinePostFecCurrent24StatInvSesPortnread-onlycurrentCurrent 24-hours SES counter inv. :This OID indicates that the current 24-hours severely Errored Second counter is invalid
1.3.6.1.4.1.20044.80.11.7.338.1.7Columnpm10010ulhPerfTelecomLinePostFecCurrent24StatSesValuePortnread-onlycurrentCurrent 24-hours SES counter :This OID gives the current 24-hours severely Errored Second counter value
1.3.6.1.4.1.20044.80.11.7.338.1.8Columnpm10010ulhPerfTelecomLinePostFecCurrent24StatInvSefsPortnread-onlycurrentCurrent 24-hours SEFS counter inv. :This OID indicates that the current 24-hours severely Errored Framing Second counter is invalid
1.3.6.1.4.1.20044.80.11.7.338.1.9Columnpm10010ulhPerfTelecomLinePostFecCurrent24StatSefsValuePortnread-onlycurrentCurrent 24-hours SEFS counter :This OID gives the current 24-hours severely Errored Framing Second counter value
1.3.6.1.4.1.20044.80.11.7.338.1.10Columnpm10010ulhPerfTelecomLinePostFecCurrent24StatInvUasPortnread-onlycurrentCurrent 24-hours UAS counter inv. :This OID indicates that the current 24-hours UnAvailable Second counter is invalid
1.3.6.1.4.1.20044.80.11.7.338.1.11Columnpm10010ulhPerfTelecomLinePostFecCurrent24StatUasValuePortnread-onlycurrentCurrent 24-hours UAS counter :This OID gives the current 24-hours UnAvailable Second counter value
1.3.6.1.4.1.20044.80.11.7.339Tablepm10010ulhPerfTelecomLinePostFecPast24StatHistoryPort1Tablenot-accessiblecurrentList of pm10010ulhPerfTelecomLinePostFecPast24StatHistory Article
1.3.6.1.4.1.20044.80.11.7.339.1Rowpm10010ulhPerfTelecomLinePostFecPast24StatHistoryPort1Entrynot-accessiblecurrentRow definition for the pm10010ulhPerfTelecomLinePostFecPast24StatHistory table
1.3.6.1.4.1.20044.80.11.7.339.1.1Columnpm10010ulhPerfTelecomLinePostFecPast24StatHistoryPort1Indexread-onlycurrentIndex definition for the pm10010ulhPerfTelecomLinePostFecPast24StatHistory table
1.3.6.1.4.1.20044.80.11.7.339.1.2Columnpm10010ulhPerfTelecomLinePostFecPast24StatHistoryInvCvPort1read-onlycurrentPrevious 24-hours EBC counter inv. :This OID indicates that the previous 24-hours Coding Violation counter is invalid
1.3.6.1.4.1.20044.80.11.7.339.1.3Columnpm10010ulhPerfTelecomLinePostFecPast24StatHistoryCvValuePort1read-onlycurrentPrevious 24-hours EBC counter :This OID gives the previous 24-hours Coding Violation counter value
1.3.6.1.4.1.20044.80.11.7.339.1.4Columnpm10010ulhPerfTelecomLinePostFecPast24StatHistoryInvEsPort1read-onlycurrentPrevious 24-hours ES counter inv. :This OID indicates that the previous 24-hours Errored Second counter is invalid
1.3.6.1.4.1.20044.80.11.7.339.1.5Columnpm10010ulhPerfTelecomLinePostFecPast24StatHistoryEsValuePort1read-onlycurrentPrevious 24-hours ES counter :This OID gives the previous 24-hours Errored Second counter value
1.3.6.1.4.1.20044.80.11.7.339.1.6Columnpm10010ulhPerfTelecomLinePostFecPast24StatHistoryInvSesPort1read-onlycurrentPrevious 24-hours SES counter inv. :This OID indicates that the previous 24-hours severely Errored Second counter is invalid
1.3.6.1.4.1.20044.80.11.7.339.1.7Columnpm10010ulhPerfTelecomLinePostFecPast24StatHistorySesValuePort1read-onlycurrentPrevious 24-hours SES counter :This OID gives the previous 24-hours severely Errored Second counter value
1.3.6.1.4.1.20044.80.11.7.339.1.8Columnpm10010ulhPerfTelecomLinePostFecPast24StatHistoryInvSefsPort1read-onlycurrentPrevious 24-hours SEFS counter inv. :This OID indicates that the previous 24-hours severely Errored Framing Second counter is invalid
1.3.6.1.4.1.20044.80.11.7.339.1.9Columnpm10010ulhPerfTelecomLinePostFecPast24StatHistorySefsValuePort1read-onlycurrentPrevious 24-hours SEFS counter :This OID gives the previous 24-hours severely Errored Framing Second counter value
1.3.6.1.4.1.20044.80.11.7.339.1.10Columnpm10010ulhPerfTelecomLinePostFecPast24StatHistoryInvUasPort1read-onlycurrentPrevious 24-hours UAS counter inv. :This OID indicates that the previous 24-hours UnAvailable Second counter is invalid
1.3.6.1.4.1.20044.80.11.7.339.1.11Columnpm10010ulhPerfTelecomLinePostFecPast24StatHistoryUasValuePort1read-onlycurrentPrevious 24-hours UAS counter :This OID gives the previous 24-hours UnAvailable Second counter value
1.3.6.1.4.1.20044.80.11.7.352Tablepm10010ulhPerfTelecomBerLinePreFecCurrent15StatTablenot-accessiblecurrentList of pm10010ulhPerfTelecomBerLinePreFecCurrent15Stat Article
1.3.6.1.4.1.20044.80.11.7.352.1Rowpm10010ulhPerfTelecomBerLinePreFecCurrent15StatEntrynot-accessiblecurrentRow definition for the pm10010ulhPerfTelecomBerLinePreFecCurrent15Stat table
1.3.6.1.4.1.20044.80.11.7.352.1.1Columnpm10010ulhPerfTelecomBerLinePreFecCurrent15StatIndexread-onlycurrentIndex definition for the pm10010ulhPerfTelecomBerLinePreFecCurrent15Stat table
1.3.6.1.4.1.20044.80.11.7.352.1.2Columnpm10010ulhPerfTelecomBerLinePreFecCurrent15StatInvBerPortnread-onlycurrentCurrent 15-min BER counter inv. :This OID indicates that the current 15-min Coding Violation counter is invalid
1.3.6.1.4.1.20044.80.11.7.352.1.3Columnpm10010ulhPerfTelecomBerLinePreFecCurrent15StatBerValuePortnread-onlycurrentCurrent 15-min BER counter :This OID gives the current 15-min Coding Violation counter value
1.3.6.1.4.1.20044.80.11.7.352.1.4Columnpm10010ulhPerfTelecomBerLinePreFecCurrent15StatInvMinBerPortnread-onlycurrentCurrent 15-min MinBER counter inv. :This OID indicates that the current 15-min Errored Second counter is invalid
1.3.6.1.4.1.20044.80.11.7.352.1.5Columnpm10010ulhPerfTelecomBerLinePreFecCurrent15StatMinBerValuePortnread-onlycurrentCurrent 15-min MinBER counter :This OID gives the current 15-min Errored Second counter value
1.3.6.1.4.1.20044.80.11.7.352.1.6Columnpm10010ulhPerfTelecomBerLinePreFecCurrent15StatInvMaxBerPortnread-onlycurrentCurrent 15-min MaxBER counter inv. :This OID indicates that the current 15-min severely Errored Second counter is invalid
1.3.6.1.4.1.20044.80.11.7.352.1.7Columnpm10010ulhPerfTelecomBerLinePreFecCurrent15StatMaxBerValuePortnread-onlycurrentCurrent 15-min MaxBER counter :This OID gives the current 15-min severely Errored Second counter value
1.3.6.1.4.1.20044.80.11.7.353Tablepm10010ulhPerfTelecomBerLinePreFecPast15StatHistoryPort1Tablenot-accessiblecurrentList of pm10010ulhPerfTelecomBerLinePreFecPast15StatHistory Article
1.3.6.1.4.1.20044.80.11.7.353.1Rowpm10010ulhPerfTelecomBerLinePreFecPast15StatHistoryPort1Entrynot-accessiblecurrentRow definition for the pm10010ulhPerfTelecomBerLinePreFecPast15StatHistory table
1.3.6.1.4.1.20044.80.11.7.353.1.1Columnpm10010ulhPerfTelecomBerLinePreFecPast15StatHistoryPort1Indexread-onlycurrentIndex definition for the pm10010ulhPerfTelecomBerLinePreFecPast15StatHistory table
1.3.6.1.4.1.20044.80.11.7.353.1.2Columnpm10010ulhPerfTelecomBerLinePreFecPast15StatHistoryInvBerPort1read-onlycurrentPrevious 15-min BER counter inv. :This OID indicates that the previous 15-min Coding Violation counter is invalid
1.3.6.1.4.1.20044.80.11.7.353.1.3Columnpm10010ulhPerfTelecomBerLinePreFecPast15StatHistoryBerValuePort1read-onlycurrentPrevious 15-min BER counter :This OID gives the previous 15-min Coding Violation counter value
1.3.6.1.4.1.20044.80.11.7.353.1.4Columnpm10010ulhPerfTelecomBerLinePreFecPast15StatHistoryInvMinBerPort1read-onlycurrentPrevious 15-min MinBER counter inv. :This OID indicates that the previous 15-min Errored Second counter is invalid
1.3.6.1.4.1.20044.80.11.7.353.1.5Columnpm10010ulhPerfTelecomBerLinePreFecPast15StatHistoryMinBerValuePort1read-onlycurrentPrevious 15-min MinBER counter :This OID gives the previous 15-min Errored Second counter value
1.3.6.1.4.1.20044.80.11.7.353.1.6Columnpm10010ulhPerfTelecomBerLinePreFecPast15StatHistoryInvMaxBerPort1read-onlycurrentPrevious 15-min MaxBER counter inv. :This OID indicates that the previous 15-min severely Errored Second counter is invalid
1.3.6.1.4.1.20044.80.11.7.353.1.7Columnpm10010ulhPerfTelecomBerLinePreFecPast15StatHistoryMaxBerValuePort1read-onlycurrentPrevious 15-min MaxBER counter :This OID gives the previous 15-min severely Errored Second counter value
1.3.6.1.4.1.20044.80.11.7.354Tablepm10010ulhPerfTelecomBerLinePreFecCurrent24StatTablenot-accessiblecurrentList of pm10010ulhPerfTelecomBerLinePreFecCurrent24Stat Article
1.3.6.1.4.1.20044.80.11.7.354.1Rowpm10010ulhPerfTelecomBerLinePreFecCurrent24StatEntrynot-accessiblecurrentRow definition for the pm10010ulhPerfTelecomBerLinePreFecCurrent24Stat table
1.3.6.1.4.1.20044.80.11.7.354.1.1Columnpm10010ulhPerfTelecomBerLinePreFecCurrent24StatIndexread-onlycurrentIndex definition for the pm10010ulhPerfTelecomBerLinePreFecCurrent24Stat table
1.3.6.1.4.1.20044.80.11.7.354.1.2Columnpm10010ulhPerfTelecomBerLinePreFecCurrent24StatInvBerPortnread-onlycurrentCurrent 24-hours BER counter inv. :This OID indicates that the current 24-hours Coding Violation counter is invalid
1.3.6.1.4.1.20044.80.11.7.354.1.3Columnpm10010ulhPerfTelecomBerLinePreFecCurrent24StatBerValuePortnread-onlycurrentCurrent 24-hours BER counter :This OID gives the current 24-hours Coding Violation counter value
1.3.6.1.4.1.20044.80.11.7.354.1.4Columnpm10010ulhPerfTelecomBerLinePreFecCurrent24StatInvMinBerPortnread-onlycurrentCurrent 24-hoursMinBER counter inv. :This OID indicates that the current 24-hours Errored Second counter is invalid
1.3.6.1.4.1.20044.80.11.7.354.1.5Columnpm10010ulhPerfTelecomBerLinePreFecCurrent24StatMinBerValuePortnread-onlycurrentCurrent 24-hours MinBER counter :This OID gives the current 24-hours Errored Second counter value
1.3.6.1.4.1.20044.80.11.7.354.1.6Columnpm10010ulhPerfTelecomBerLinePreFecCurrent24StatInvMaxBerPortnread-onlycurrentCurrent 24-hours MaxBER counter inv. :This OID indicates that the current 24-hours severely Errored Second counter is invalid
1.3.6.1.4.1.20044.80.11.7.354.1.7Columnpm10010ulhPerfTelecomBerLinePreFecCurrent24StatMaxBerValuePortnread-onlycurrentCurrent 24-hours MaxBER counter :This OID gives the current 24-hours severely Errored Second counter value
1.3.6.1.4.1.20044.80.11.7.355Tablepm10010ulhPerfTelecomBerLinePreFecPast24StatHistoryPort1Tablenot-accessiblecurrentList of pm10010ulhPerfTelecomBerLinePreFecPast24StatHistory Article
1.3.6.1.4.1.20044.80.11.7.355.1Rowpm10010ulhPerfTelecomBerLinePreFecPast24StatHistoryPort1Entrynot-accessiblecurrentRow definition for the pm10010ulhPerfTelecomBerLinePreFecPast24StatHistory table
1.3.6.1.4.1.20044.80.11.7.355.1.1Columnpm10010ulhPerfTelecomBerLinePreFecPast24StatHistoryPort1Indexread-onlycurrentIndex definition for the pm10010ulhPerfTelecomBerLinePreFecPast24StatHistory table
1.3.6.1.4.1.20044.80.11.7.355.1.2Columnpm10010ulhPerfTelecomBerLinePreFecPast24StatHistoryInvBerPort1read-onlycurrentPrevious 24-hours BER counter inv. :This OID indicates that the previous 24-hours Coding Violation counter is invalid
1.3.6.1.4.1.20044.80.11.7.355.1.3Columnpm10010ulhPerfTelecomBerLinePreFecPast24StatHistoryBerValuePort1read-onlycurrentPrevious 24-hours BER counter :This OID gives the previous 24-hours Coding Violation counter value
1.3.6.1.4.1.20044.80.11.7.355.1.4Columnpm10010ulhPerfTelecomBerLinePreFecPast24StatHistoryInvMinBerPort1read-onlycurrentPrevious 24-hours MinBER counter inv. :This OID indicates that the previous 24-hours Errored Second counter is invalid
1.3.6.1.4.1.20044.80.11.7.355.1.5Columnpm10010ulhPerfTelecomBerLinePreFecPast24StatHistoryMinBerValuePort1read-onlycurrentPrevious 24-hours MinBER counter :This OID gives the previous 24-hours Errored Second counter value
1.3.6.1.4.1.20044.80.11.7.355.1.6Columnpm10010ulhPerfTelecomBerLinePreFecPast24StatHistoryInvMaxBerPort1read-onlycurrentPrevious 24-hours MaxBER counter inv. :This OID indicates that the previous 24-hours severely Errored Second counter is invalid
1.3.6.1.4.1.20044.80.11.7.355.1.7Columnpm10010ulhPerfTelecomBerLinePreFecPast24StatHistoryMaxBerValuePort1read-onlycurrentPrevious 24-hours MaxBER counter :This OID gives the previous 24-hours severely Errored Second counter value
Type Definitions
NameSyntaxStatusDescription
Pm10010ulhAdjustValueINTEGER { otxadjustvalue0(0), otxadjustvalue1(1), otxadjustvalue2(2), otxadjustvalue3(3), otxadjustvalue4(4), otxadjustvalue5(5), otxadjustvalue6(6), otxadjustvalue7(7), otxadjustvalue8(8), otxadjustvalue9(9), otxadjustvalue10(10) }currentDifferent values in Adjust mode on OTX-TLH on client and line ports
Pm10010ulhClientProtocolINTEGER { protocolclientvalue0(0), protocolclientvalue1(1), protocolclientvalue2(2), protocolclientvalue3(3), protocolclientvalue4(4), protocolclientvalue5(5), protocolclientvalue6(6), protocolclientvalue7(7), protocolclientvalue8(8) }currentDifferent values on the protocol on the client ports
Pm10010ulhDccModeINTEGER { dccNo(0), dccLine1(1), dccLine2(2) }currentMode for DCC
Pm10010ulhModuleModeINTEGER { unusedmode(0), mode200gma(1), mode200gmr(2), mode100gulh(3) }currentMode for the module
Pm10010ulhMultiRateINTEGER { rate100Mhz(0), rate250Mhz(1), rate500Mhz(2), rate1Ghz(3) }currentdifferent rate for a client port
Pm10010ulhOrxChannelINTEGERcurrentChannel selection on transceiver Rx line ports
Pm10010ulhOtxChannelINTEGERcurrentChannel selection on transceiver Tx line ports
Pm10010ulhOtxGridINTEGER { otxgrid200(200), otxgrid100(100), otxgrid50(50) }currentDifferent grids on OTX-TLH on client and line ports
Pm10010ulhOtxModeINTEGER { otx80mode(1), otx60mode(2), otxadjustmode(4) }currentDifferent modes on OTX-TLH on client and line ports
Pm10010ulhProtocolModeINTEGER { protocolmodevalue0(0), protocolmodevalue1(1), protocolmodevalue2(2), protocolmodevalue3(3) }currentDifferent values on the protocol mode