EKINOPS-Pm1001lhr-MIB
376 objects
MIB for managing Ekinops modules with PM1001LHR software
Imported Objects
| EKINOPS-MIB | EkiApiState EkiMeasureType EkiMode ekinops EkiOnOff EkiProtocol EkiState EkiSynchroMode |
| SNMPv2-SMI | Counter32 Integer32 IpAddress MODULE-IDENTITY NOTIFICATION-TYPE OBJECT-TYPE Unsigned32 |
| SNMPv2-TC | DisplayString TEXTUAL-CONVENTION |
| OID | Name | Access | Status | Description |
|---|---|---|---|---|
| 1.3.6.1.4.1.20044.22 | IdentitymodulePm1001lhr | MIB for managing Ekinops modules with PM1001LHR software | ||
| 1.3.6.1.4.1.20044.22.2 | Nodepm1001lhralarms | |||
| 1.3.6.1.4.1.20044.22.2.1 | Nodepm1001lhrAlmOther | |||
| 1.3.6.1.4.1.20044.22.2.1.1 | Nodepm1001lhrAlmOtherNurg | |||
| 1.3.6.1.4.1.20044.22.2.1.1.2 | Nodepm1001lhrAlmsynthAlm2 | |||
| 1.3.6.1.4.1.20044.22.2.1.1.2.1 | Scalarpm1001lhrAlmConfTableSave | read-only | current | PM Configuration Save :This OID is at 1 during the saving of a new configuration table in the module Flash memory. <Condtype> CONF_TABLE_SAVE <Probcause> other… |
| 1.3.6.1.4.1.20044.22.2.1.1.2.2 | Scalarpm1001lhrAlmInvUpload | read-only | current | Inventory Upload :This OID is at 1 during the uploading of PM inventory information. <Condtype> INV_UPLOAD <Probcause> other (1) <Alarmtype> other (1) <Polarit… |
| 1.3.6.1.4.1.20044.22.2.1.1.2.3 | Scalarpm1001lhrAlmConfTableLoad | read-only | current | PM Configuration Load :This OID is at 1 during the loading of configuration tables in the modules RAM. <Condtype> CONF_TABLE_LOAD <Probcause> other (1) <Alarmt… |
| 1.3.6.1.4.1.20044.22.2.1.1.2.4 | Scalarpm1001lhrAlmCorrelatOff | read-only | current | Not Used :This OID, when set, indicates that alarm correlation is not being performed. <Condtype> CORRELAT_OFF <Probcause> other (1) <Alarmtype> other (1) <Pol… |
| 1.3.6.1.4.1.20044.22.2.1.2 | Nodepm1001lhrAlmOtherUrg | |||
| 1.3.6.1.4.1.20044.22.2.1.2.194 | Nodepm1001lhrAlmmodInitFailLevel2 | |||
| 1.3.6.1.4.1.20044.22.2.1.2.194.1 | Scalarpm1001lhrAlmLedFail | read-only | current | Led Fail :This OID indicates that Led register has not been correctly initalized <Help> This alarm indicates if the module LEDs are correctly initialized <Cond… |
| 1.3.6.1.4.1.20044.22.2.1.2.194.2 | Scalarpm1001lhrAlmNextColdBootForced | read-only | current | Next Cold Boot Forced :This OID indicates that the next Reset will be forced Cold <Help> This alarm indicates that the next reset of the module will be forced … |
| 1.3.6.1.4.1.20044.22.2.1.2.194.3 | Scalarpm1001lhrAlmBootUndone | read-only | current | Boot Undone :This OID indicates that the boot has not been correctly achieved <Help> This alarm indicates if the module has correctly boot <Condtype> BOOT_UNDO… |
| 1.3.6.1.4.1.20044.22.2.1.2.194.4 | Scalarpm1001lhrAlmResetHwInitFail | read-only | current | Reset HW Init Fail :This OID indicates that the HW intialization has caused unknown intial conditions <Help> This alarm indicates if the HW has been correctly … |
| 1.3.6.1.4.1.20044.22.2.1.2.194.5 | Scalarpm1001lhrAlmSwInitFail | read-only | current | SW Init Fail :This OID indicates that the SW intialization has caused unknown intial conditions <Help> This alarm indicates if the SW module is correctly initi… |
| 1.3.6.1.4.1.20044.22.2.1.2.195 | Nodepm1001lhrAlmmodInitFailLevel3 | |||
| 1.3.6.1.4.1.20044.22.2.1.2.195.1 | Scalarpm1001lhrAlmGwIdentFail | read-only | current | GW Ident Fail :This OID indicates that GW identification has not been read <Help> This alarm indicates if the GW has been correctly identified <Condtype> GW_ID… |
| 1.3.6.1.4.1.20044.22.2.1.2.195.2 | Scalarpm1001lhrAlmObmTypeReadFail | read-only | current | OBM Type Read Fail :This OID indicates that OBM type has not been recognized <Help> This alarm indicates if the OBM board has been correctly identified <Condty… |
| 1.3.6.1.4.1.20044.22.2.1.2.195.3 | Scalarpm1001lhrAlmInitModuleFail | read-only | current | Init Module Fail :This OID indicates that the Module has not been correctly initialized <Help> This alarm indicates if the SW module is correctly initialized <… |
| 1.3.6.1.4.1.20044.22.2.1.2.195.5 | Scalarpm1001lhrAlmXfp1InitFail | read-only | current | XFP1 Init Fail :This OID indicates that the XFP has not been correctly initialized <Help> This alarm indicates if the line transceiver 1 is correctly initializ… |
| 1.3.6.1.4.1.20044.22.2.1.2.195.6 | Scalarpm1001lhrAlmXfp2InitFail | read-only | current | XFP2 Init Fail :This OID indicates that the XFP has not been correctly initialized <Help> This alarm indicates if the line transceiver 2 is correctly initializ… |
| 1.3.6.1.4.1.20044.22.2.1.2.195.7 | Scalarpm1001lhrAlmLine1InitFail | read-only | current | Line1 Init Fail :This OID indicates that the Line registersvsubset has not been correctly initialized <Help> This alarm indicates if the line port 1 is correct… |
| 1.3.6.1.4.1.20044.22.2.1.2.195.8 | Scalarpm1001lhrAlmLine2InitFail | read-only | current | Line2 Init Fail :This OID indicates that the Line register subset has not been correctly initialized <Help> This alarm indicates if the line port 2 is correctl… |
| 1.3.6.1.4.1.20044.22.2.1.3 | Nodepm1001lhrAlmOtherCrit | |||
| 1.3.6.1.4.1.20044.22.2.1.3.0 | Nodepm1001lhrAlmsynthAlm0 | |||
| 1.3.6.1.4.1.20044.22.2.1.3.0.9 | Scalarpm1001lhrAlmModGlobFail | read-only | current | Module Failure :This OID is set on detection of a failure originating from the PM <Condtype> MOD_GLOB_FAIL <Probcause> equipmentMalfunction (16) <Alarmtype> sy… |
| 1.3.6.1.4.1.20044.22.2.1.3.0.15 | Scalarpm1001lhrAlmDefFuseA | read-only | current | Fuse A Fail :This OID indicates that the fuse of the power input A is in fail condition <Help> Status of the Fuse A <Condtype> DEF_FUSE_A <Probcause> powerProb… |
| 1.3.6.1.4.1.20044.22.2.1.3.0.16 | Scalarpm1001lhrAlmDefFuseB | read-only | current | Fuse B Fail :This OID indicates that the fuse of the power input B is in fail condition <Help> Status of the Fuse B <Condtype> DEF_FUSE_B <Probcause> powerProb… |
| 1.3.6.1.4.1.20044.22.2.2 | Nodepm1001lhrAlmClient | |||
| 1.3.6.1.4.1.20044.22.2.2.1 | Nodepm1001lhrAlmClientNurg | |||
| 1.3.6.1.4.1.20044.22.2.2.2 | Nodepm1001lhrAlmClientUrg | |||
| 1.3.6.1.4.1.20044.22.2.2.3 | Nodepm1001lhrAlmClientCrit | |||
| 1.3.6.1.4.1.20044.22.2.3 | Nodepm1001lhrAlmLine | |||
| 1.3.6.1.4.1.20044.22.2.3.1 | Nodepm1001lhrAlmLineNurg | |||
| 1.3.6.1.4.1.20044.22.2.3.1.209 | Tablepm1001lhrAlmlineXfp1WarningsTable | not-accessible | current | List of pm1001lhrAlmlineXfp1Warnings Article |
| 1.3.6.1.4.1.20044.22.2.3.1.209.1 | Rowpm1001lhrAlmlineXfp1WarningsEntry | not-accessible | current | Row definition for the pm1001lhrAlmlineXfp1Warnings table |
| 1.3.6.1.4.1.20044.22.2.3.1.209.1.1 | Columnpm1001lhrAlmlineXfp1WarningsIndex | read-only | current | Index definition for the pm1001lhrAlmlineXfp1Warnings table |
| 1.3.6.1.4.1.20044.22.2.3.1.209.1.2 | Columnpm1001lhrAlmTxPowerLowWarningPortn | read-only | current | Line Optical Tx Power Low Warning :Warning indicating that the XFP/OTX transmitter transmitter output power is lower than the threshold value written in the XF… |
| 1.3.6.1.4.1.20044.22.2.3.1.209.1.3 | Columnpm1001lhrAlmTxPowerHighWarningPortn | read-only | current | Line Optical Tx Power High Warning :Warning indicating that the XFP/OTX transmitter transmitter output power is higher than the threshold value written in the … |
| 1.3.6.1.4.1.20044.22.2.3.1.209.1.4 | Columnpm1001lhrAlmTxBiasLowWarningPortn | read-only | current | Line Transceiver Bias Low Warning :Warning indicating that the XFP/OTX transmitter laser bias current is lower than the threshold value written in the XFP/OTX … |
| 1.3.6.1.4.1.20044.22.2.3.1.209.1.5 | Columnpm1001lhrAlmTxBiasHighWarningPortn | read-only | current | Line Transceiver Bias High Warning :Warning indicating that the XFP/OTX transmitter laser bias current is higher than the threshold value written in the XFP EE… |
| 1.3.6.1.4.1.20044.22.2.3.1.209.1.8 | Columnpm1001lhrAlmTempLowWarningPortn | read-only | current | Line Transceiver Temp Low Warning :Warning indicating that the XFP/OTX temperature is lower than the threshold value written in the XFP/OTX EEPROM <Condtype> T… |
| 1.3.6.1.4.1.20044.22.2.3.1.209.1.9 | Columnpm1001lhrAlmTempHighWarningPortn | read-only | current | Line Transceiver Temp High Warning :Warning indicating that the XFP/OTX temperature is higher than the threshold value written in the XFP EEPROM <Condtype> TEM… |
| 1.3.6.1.4.1.20044.22.2.3.1.209.1.16 | Columnpm1001lhrAlmRxPowerLowWarningPortn | read-only | current | Line Optical Rx Power Low Warning :Warning indicating that the XFP received optical power is lower than the threshold value written in the XFP EEPROM <Condtype… |
| 1.3.6.1.4.1.20044.22.2.3.1.209.1.17 | Columnpm1001lhrAlmRxPowerHighWarningPortn | read-only | current | Line Optical Rx Power High Warning :Warning indicating that the XFP received optical power is higher than the threshold value written in the XFP EEPROM <Condty… |
| 1.3.6.1.4.1.20044.22.2.3.1.225 | Tablepm1001lhrAlmlineOtx1TlhWarningsTable | not-accessible | current | List of pm1001lhrAlmlineOtx1TlhWarnings Article |
| 1.3.6.1.4.1.20044.22.2.3.1.225.1 | Rowpm1001lhrAlmlineOtx1TlhWarningsEntry | not-accessible | current | Row definition for the pm1001lhrAlmlineOtx1TlhWarnings table |
| 1.3.6.1.4.1.20044.22.2.3.1.225.1.1 | Columnpm1001lhrAlmlineOtx1TlhWarningsIndex | read-only | current | Index definition for the pm1001lhrAlmlineOtx1TlhWarnings table |
| 1.3.6.1.4.1.20044.22.2.3.1.225.1.6 | Columnpm1001lhrAlmLineModulatorAgingHighWarningPortn | read-only | current | Line Modulator Aging High Warning :Warning indicating the Line OTX TLH modulator aging is higher than the threshold written in the EEPROM <Condtype> LINE_MODUL… |
| 1.3.6.1.4.1.20044.22.2.3.1.225.1.7 | Columnpm1001lhrAlmLineAgingHighWarningPortn | read-only | current | Line OTX TLH Aging High Warning :Warning indicating the Line OTX TLH aging is higher than the threshold written in the EEPROM <Condtype> LINE_AGING_HIGH_WARNIN… |
| 1.3.6.1.4.1.20044.22.2.3.1.225.1.13 | Columnpm1001lhrAlmLineFreqDevHighWarningPortn | read-only | current | Line Freq. Deviation High Warning :Warning indicating the Line OTX TLH frequency deviation is higher than the threshold written in the EEPROM <Condtype> LINE_F… |
| 1.3.6.1.4.1.20044.22.2.3.1.225.1.15 | Columnpm1001lhrAlmLineLaserTempHighWarningPortn | read-only | current | Line Laser Temp. High Warning :Warning indicating the Line OTX TLH laser temperature is higher than the threshold written in the EEPROM <Condtype> LINE_LASER_T… |
| 1.3.6.1.4.1.20044.22.2.3.2 | Nodepm1001lhrAlmLineUrg | |||
| 1.3.6.1.4.1.20044.22.2.3.2.129 | Tablepm1001lhrAlmdfrmBerTable | not-accessible | current | List of pm1001lhrAlmdfrmBer Article |
| 1.3.6.1.4.1.20044.22.2.3.2.129.1 | Rowpm1001lhrAlmdfrmBerEntry | not-accessible | current | Row definition for the pm1001lhrAlmdfrmBer table |
| 1.3.6.1.4.1.20044.22.2.3.2.129.1.1 | Columnpm1001lhrAlmdfrmBerIndex | read-only | current | Index definition for the pm1001lhrAlmdfrmBer table |
| 1.3.6.1.4.1.20044.22.2.3.2.129.1.2 | Columnpm1001lhrAlmLineSignalDegradePortn | read-only | current | Custom Line Signal Degrade :This OID indicates that the line input signal is DEGRADE. The assertion hysteresis can customized by the host <Condtype> LINE_SIGNA… |
| 1.3.6.1.4.1.20044.22.2.3.2.129.1.3 | Columnpm1001lhrAlmLineSignalFailPortn | read-only | current | Custom Line Signal Fail :This OID indicates that the line input signal is FAIL. The assertion hysteresis can be customized by the host <Condtype> LINE_SIGNAL_F… |
| 1.3.6.1.4.1.20044.22.2.3.2.129.1.6 | Columnpm1001lhrAlmLineDegradePortn | read-only | current | Fixed Line Signal Degrade :This OID indicates that the line input signal is DEGRADE. The assetion hysteresis is fixed to 10-8 (assertion) and 10-9 (de-assertio… |
| 1.3.6.1.4.1.20044.22.2.3.2.208 | Tablepm1001lhrAlmlineXfp1AlarmTable | not-accessible | current | List of pm1001lhrAlmlineXfp1Alarm Article |
| 1.3.6.1.4.1.20044.22.2.3.2.208.1 | Rowpm1001lhrAlmlineXfp1AlarmEntry | not-accessible | current | Row definition for the pm1001lhrAlmlineXfp1Alarm table |
| 1.3.6.1.4.1.20044.22.2.3.2.208.1.1 | Columnpm1001lhrAlmlineXfp1AlarmIndex | read-only | current | Index definition for the pm1001lhrAlmlineXfp1Alarm table |
| 1.3.6.1.4.1.20044.22.2.3.2.208.1.2 | Columnpm1001lhrAlmTxPowerLowAlarmPortn | read-only | current | Line Optical Tx Power Low :Alarm indicating that the XFP/OTX transmitter transmitter output power is lower than the threshold value written in the XFP/OTX EEPR… |
| 1.3.6.1.4.1.20044.22.2.3.2.208.1.3 | Columnpm1001lhrAlmTxPowerHighAlarmPortn | read-only | current | Line Optical Tx Power High :Alarm indicating that the XFP/OTX transmitter transmitter output power is higher than the threshold value written in the XFP EEPROM… |
| 1.3.6.1.4.1.20044.22.2.3.2.208.1.4 | Columnpm1001lhrAlmTxBiasLowAlarmPortn | read-only | current | Line Transceiver Bias Low :Alarm indicating that the XFP/OTX transmitter laser bias current is lower than the threshold value written in the XFP/OTX EEPROM <Co… |
| 1.3.6.1.4.1.20044.22.2.3.2.208.1.5 | Columnpm1001lhrAlmTxBiasHighAlarmPortn | read-only | current | Line Transceiver Bias High :Alarm indicating that the XFP/OTX transmitter laser bias current is higher than the threshold value written in the XFP EEPROM <Cond… |
| 1.3.6.1.4.1.20044.22.2.3.2.208.1.8 | Columnpm1001lhrAlmTempLowAlarmPortn | read-only | current | Line Transceiver Temp Low :Alarm indicating that the XFP/OTX temperature is lower than the threshold value written in the XFP/OTX EEPROM <Condtype> TEMP_LOW_AL… |
| 1.3.6.1.4.1.20044.22.2.3.2.208.1.9 | Columnpm1001lhrAlmTempHighAlarmPortn | read-only | current | Line Transceiver Temp High :Alarm indicating that the XFP/OTX temperature is higher than the threshold value written in the XFP EEPROM <Condtype> TEMP_HIGH_ALA… |
| 1.3.6.1.4.1.20044.22.2.3.2.208.1.16 | Columnpm1001lhrAlmRxPowerLowAlarmPortn | read-only | current | Line Optical Rx Power Low :Alarm indicating that the XFP received optical power is lower than the threshold value written in the XFP EEPROM <Condtype> RX_POWER… |
| 1.3.6.1.4.1.20044.22.2.3.2.208.1.17 | Columnpm1001lhrAlmRxPowerHighAlarmPortn | read-only | current | Line Optical Rx Power High :Alarm indicating that the XFP received optical power is higher than the threshold value written in the XFP EEPROM <Condtype> RX_POW… |
| 1.3.6.1.4.1.20044.22.2.3.2.212 | Tablepm1001lhrAlmlineXfp1SupplyAlarmTable | not-accessible | current | List of pm1001lhrAlmlineXfp1SupplyAlarm Article |
| 1.3.6.1.4.1.20044.22.2.3.2.212.1 | Rowpm1001lhrAlmlineXfp1SupplyAlarmEntry | not-accessible | current | Row definition for the pm1001lhrAlmlineXfp1SupplyAlarm table |
| 1.3.6.1.4.1.20044.22.2.3.2.212.1.1 | Columnpm1001lhrAlmlineXfp1SupplyAlarmIndex | read-only | current | Index definition for the pm1001lhrAlmlineXfp1SupplyAlarm table |
| 1.3.6.1.4.1.20044.22.2.3.2.212.1.2 | Columnpm1001lhrAlmVee5LowAlarmPortn | read-only | current | VEE5 Power Supply Low :Alarm indicating the XFP/OTX VEE5 power supply is lower than the threshold written in the EEPROM <Condtype> VEE5_LOW_ALARM_1 <Probcause>… |
| 1.3.6.1.4.1.20044.22.2.3.2.212.1.3 | Columnpm1001lhrAlmVee5HighAlarmPortn | read-only | current | VEE5 Power Supply High :Alarm indicating the XFP/OTX VEE5 power supply is higher than the threshold written in the EEPROM <Condtype> VEE5_HIGH_ALARM_1 <Probcau… |
| 1.3.6.1.4.1.20044.22.2.3.2.212.1.4 | Columnpm1001lhrAlmVcc2LowAlarmPortn | read-only | current | VCC2 Power Supply Low :Alarm indicating the XFP/OTX VCC2 power supply is lower than the threshold written in the EEPROM <Condtype> VCC2_LOW_ALARM_1 <Probcause>… |
| 1.3.6.1.4.1.20044.22.2.3.2.212.1.5 | Columnpm1001lhrAlmVcc2HighAlarmPortn | read-only | current | VCC2 Power Supply High :Alarm indicating the XFP/OTX VCC2 power supply is higher than the threshold written in the EEPROM <Condtype> VCC2_HIGH_ALARM_1 <Probcau… |
| 1.3.6.1.4.1.20044.22.2.3.2.212.1.6 | Columnpm1001lhrAlmVcc3LowAlarmPortn | read-only | current | VCC3 Power Supply Low :Alarm indicating the XFP/OTX VCC3 power supply is lower than the threshold written in the EEPROM <Condtype> VCC3_LOW_ALARM_1 <Probcause>… |
| 1.3.6.1.4.1.20044.22.2.3.2.212.1.7 | Columnpm1001lhrAlmVcc3HighAlarmPortn | read-only | current | VCC3 Power Supply High :Alarm indicating the XFP/OTX VCC3 power supply is higher than the threshold written in the EEPROM <Condtype> VCC3_HIGH_ALARM_1 <Probcau… |
| 1.3.6.1.4.1.20044.22.2.3.2.212.1.8 | Columnpm1001lhrAlmVcc5LowAlarmPortn | read-only | current | VCC5 Power Supply Low :Alarm indicating the XFP/OTX VCC5 power supply is lower than the threshold written in the EEPROM <Condtype> VCC5_LOW_ALARM_1 <Probcause>… |
| 1.3.6.1.4.1.20044.22.2.3.2.212.1.9 | Columnpm1001lhrAlmVcc5HighAlarmPortn | read-only | current | VCC5 Power Supply High :Alarm indicating the XFP/OTX VCC5 power supply is higher than the threshold written in the EEPROM <Condtype> VCC5_HIGH_ALARM_1 <Probcau… |
| 1.3.6.1.4.1.20044.22.2.3.2.212.1.10 | Columnpm1001lhrAlmVee5LowWarningPortn | read-only | current | VEE5 Power Supply Low Warning :Warning indicating the XFP/OTX VEE5 power supply is lower than the threshold written in the EEPROM <Condtype> VEE5_LOW_WARNING_1… |
| 1.3.6.1.4.1.20044.22.2.3.2.212.1.11 | Columnpm1001lhrAlmVee5HighWarningPortn | read-only | current | VEE5 Power Supply High Warning :Warning indicating the XFP/OTX VEE5 power supply is higher than the threshold written in the EEPROM <Condtype> VEE5_HIGH_WARNIN… |
| 1.3.6.1.4.1.20044.22.2.3.2.212.1.12 | Columnpm1001lhrAlmVcc2LowWarningPortn | read-only | current | VCC2 Power Supply Low Warning :Warning indicating the XFP/OTX VCC2 power supply is lower than the threshold written in the EEPROM <Condtype> VCC2_LOW_WARNING_1… |
| 1.3.6.1.4.1.20044.22.2.3.2.212.1.13 | Columnpm1001lhrAlmVcc2HighWarningPortn | read-only | current | VCC2 Power Supply High Warning :Warning indicating the XFP/OTX VCC2 power supply is higher than the threshold written in the EEPROM <Condtype> VCC2_HIGH_WARNIN… |
| 1.3.6.1.4.1.20044.22.2.3.2.212.1.14 | Columnpm1001lhrAlmVcc3LowWarningPortn | read-only | current | VCC3 Power Supply Low Warning :Warning indicating the XFP/OTX VCC3 power supply is lower than the threshold written in the EEPROM <Condtype> VCC3_LOW_WARNING_1… |
| 1.3.6.1.4.1.20044.22.2.3.2.212.1.15 | Columnpm1001lhrAlmVcc3HighWarningPortn | read-only | current | VCC3 Power Supply High Warning :Warning indicating the XFP/OTX VCC3 power supply is higher than the threshold written in the EEPROM <Condtype> VCC3_HIGH_WARNIN… |
| 1.3.6.1.4.1.20044.22.2.3.2.212.1.16 | Columnpm1001lhrAlmVcc5LowWarningPortn | read-only | current | VCC5 Power Supply Low Warning :Warning indicating the XFP/OTX VCC5 power supply is lower than the threshold written in the EEPROM <Condtype> VCC5_LOW_WARNING_1… |
| 1.3.6.1.4.1.20044.22.2.3.2.212.1.17 | Columnpm1001lhrAlmVcc5HighWarningPortn | read-only | current | VCC5 Power Supply High Warning :Warning indicating the XFP/OTX VCC5 power supply is higher than the threshold written in the EEPROM <Condtype> VCC5_HIGH_WARNIN… |
| 1.3.6.1.4.1.20044.22.2.3.2.224 | Tablepm1001lhrAlmlineOtx1TlhAlarmsTable | not-accessible | current | List of pm1001lhrAlmlineOtx1TlhAlarms Article |
| 1.3.6.1.4.1.20044.22.2.3.2.224.1 | Rowpm1001lhrAlmlineOtx1TlhAlarmsEntry | not-accessible | current | Row definition for the pm1001lhrAlmlineOtx1TlhAlarms table |
| 1.3.6.1.4.1.20044.22.2.3.2.224.1.1 | Columnpm1001lhrAlmlineOtx1TlhAlarmsIndex | read-only | current | Index definition for the pm1001lhrAlmlineOtx1TlhAlarms table |
| 1.3.6.1.4.1.20044.22.2.3.2.224.1.6 | Columnpm1001lhrAlmLineModulatorAgingHighAlaPortn | read-only | current | Line Modulator Aging High Alarm :Alarm indicating the Line OTX TLH modulator aging is higher than the threshold written in the EEPROM <Condtype> LINE_MODULATOR… |
| 1.3.6.1.4.1.20044.22.2.3.2.224.1.7 | Columnpm1001lhrAlmLineAgingHighAlaPortn | read-only | current | Line OTX TLH Aging High Alarm :Alarm indicating the Line OTX TLH aging is higher than the threshold written in the EEPROM <Condtype> LINE_AGING_HIGH_ALA_1 <Pro… |
| 1.3.6.1.4.1.20044.22.2.3.2.224.1.13 | Columnpm1001lhrAlmLineFreqDevHighAlaPortn | read-only | current | Line Freq. Deviation High Alarm :Alarm indicating the Line OTX TLH frequency deviation is higher than the threshold written in the EEPROM <Condtype> LINE_FREQ_… |
| 1.3.6.1.4.1.20044.22.2.3.2.224.1.15 | Columnpm1001lhrAlmLineLaserTempHighAlaPortn | read-only | current | Line Laser Temp. High Alarm :Alarm indicating the Line OTX TLH laser temperature is higher than the threshold written in the EEPROM <Condtype> LINE_LASER_TEMP_… |
| 1.3.6.1.4.1.20044.22.2.3.3 | Nodepm1001lhrAlmLineCrit | |||
| 1.3.6.1.4.1.20044.22.2.3.3.7 | Tablepm1001lhrAlmsynthAlmLineTable | not-accessible | current | List of pm1001lhrAlmsynthAlmLine Article |
| 1.3.6.1.4.1.20044.22.2.3.3.7.1 | Rowpm1001lhrAlmsynthAlmLineEntry | not-accessible | current | Row definition for the pm1001lhrAlmsynthAlmLine table |
| 1.3.6.1.4.1.20044.22.2.3.3.7.1.1 | Columnpm1001lhrAlmsynthAlmLineIndex | read-only | current | Index definition for the pm1001lhrAlmsynthAlmLine table |
| 1.3.6.1.4.1.20044.22.2.3.3.7.1.2 | Columnpm1001lhrAlmXfpAbsentPortn | read-only | current | Line Optical Module Absent :This OID indicates that the line optical interface (XFP or OTX) is not plugged in. <Help> This alarm indicates if the line transcei… |
| 1.3.6.1.4.1.20044.22.2.3.3.7.1.3 | Columnpm1001lhrAlmXfpInitNotComplPortn | read-only | current | Line Optical Module Ready :This OID indicates that the optical interface (XFP or OTX) is not operational. <Help> This status indicates if the line transceiver … |
| 1.3.6.1.4.1.20044.22.2.3.3.7.1.5 | Columnpm1001lhrAlmLineHwFailPortn | read-only | current | Line Port HW Failure :This OID indicates a failure on line port, most probably caused by a HW issue <Condtype> LINE_HW_FAIL <Probcause> equipmentMalfunction (1… |
| 1.3.6.1.4.1.20044.22.2.3.3.7.1.6 | Columnpm1001lhrAlmXfpTxOffPortn | read-only | current | Line Optical Laser Shutdown :This OID indicates the line optical output power is on <Help> This status indicates if the line transceiver laser is ON or OFF <Co… |
| 1.3.6.1.4.1.20044.22.2.3.3.7.1.7 | Columnpm1001lhrAlmLineLocalOosPortn | read-only | current | Line Port In Service :This OID indicates that the Line port is In Service (1) of Out or Service (2) <Help> This status indicates if the line port is in service… |
| 1.3.6.1.4.1.20044.22.2.3.3.7.1.10 | Columnpm1001lhrAlmLineDdmWarningPortn | read-only | current | Warning On Line Optical Module DDM :This OID indicates a warning is present coming out of Line optical interface DDM <Help> This alarm indicates if a DDM Warni… |
| 1.3.6.1.4.1.20044.22.2.3.3.7.1.11 | Columnpm1001lhrAlmLineDdmAlmPortn | read-only | current | Alarm On Line Optical Module DDM :This OID indicates an alarm is present coming out of Line optical interface DDM <Help> This alarm indicates if a DDM Alarm ha… |
| 1.3.6.1.4.1.20044.22.2.3.3.7.1.13 | Columnpm1001lhrAlmLineFailPortn | read-only | current | Line Port Failure :This OID indicates a failure on the line port <Condtype> LINE_FAIL <Probcause> equipmentMalfunction (16) <Alarmtype> synthesisAlarm (12) <Po… |
| 1.3.6.1.4.1.20044.22.2.3.3.128 | Tablepm1001lhrAlmdfrmAlmTable | not-accessible | current | List of pm1001lhrAlmdfrmAlm Article |
| 1.3.6.1.4.1.20044.22.2.3.3.128.1 | Rowpm1001lhrAlmdfrmAlmEntry | not-accessible | current | Row definition for the pm1001lhrAlmdfrmAlm table |
| 1.3.6.1.4.1.20044.22.2.3.3.128.1.1 | Columnpm1001lhrAlmdfrmAlmIndex | read-only | current | Index definition for the pm1001lhrAlmdfrmAlm table |
| 1.3.6.1.4.1.20044.22.2.3.3.128.1.2 | Columnpm1001lhrAlmDwAisDetPortn | read-only | current | MS-AIS/L-AIS Detected On Line Input :This bit indicates that an MS-AIS has been detected on incoming OC-192c/STM-64c input signal <Help> This alarm indicates i… |
| 1.3.6.1.4.1.20044.22.2.3.3.128.1.3 | Columnpm1001lhrAlmDwRdiDetPortn | read-only | current | MS-RDI/L-RDI Detected On Line Input :This bit indicates that an MS-RDI has been detected on incoming OC-192c/STM-64c input signal <Help> This alarm indicates i… |
| 1.3.6.1.4.1.20044.22.2.3.3.128.1.4 | Columnpm1001lhrAlmDwOofPortn | read-only | current | SONET/SDH Line Out Of Frame :This OID indicates that an Out Of Frame has been detected on incoming input signal <Help> This alarm indicates if there is a Out o… |
| 1.3.6.1.4.1.20044.22.2.3.3.128.1.5 | Columnpm1001lhrAlmDwLofPortn | read-only | current | SONET/SDH Line Loss Of Frame :This OID indicates that a Loss Of Frame has been detected on incoming input signal <Help> This alarm indicates if there is a Loss… |
| 1.3.6.1.4.1.20044.22.2.3.3.133 | Tablepm1001lhrAlmlineSyncAlarmsTable | not-accessible | current | List of pm1001lhrAlmlineSyncAlarms Article |
| 1.3.6.1.4.1.20044.22.2.3.3.133.1 | Rowpm1001lhrAlmlineSyncAlarmsEntry | not-accessible | current | Row definition for the pm1001lhrAlmlineSyncAlarms table |
| 1.3.6.1.4.1.20044.22.2.3.3.133.1.1 | Columnpm1001lhrAlmlineSyncAlarmsIndex | read-only | current | Index definition for the pm1001lhrAlmlineSyncAlarms table |
| 1.3.6.1.4.1.20044.22.2.3.3.133.1.13 | Columnpm1001lhrAlmDwLockerrPortn | read-only | current | Downstream Clock Lock Error :This OID indicates that the deserializer input 10 Gb/s clock recovery is not locked. <Condtype> DW_LOCKERR <Probcause> receiveFail… |
| 1.3.6.1.4.1.20044.22.2.3.3.133.1.14 | Columnpm1001lhrAlmUpLockerrPortn | read-only | current | Upstream Clock Lock Error :This OID indicates that the serializer output 10 Gb/s clock multiplier unit is not locked. <Condtype> UP_LOCKERR <Probcause> receive… |
| 1.3.6.1.4.1.20044.22.2.3.3.133.1.17 | Columnpm1001lhrAlmDwLosPortn | read-only | current | Line Input Loss Of Signal :This OID indicates a loss of signal on the 10 Gb/s input. <Help> This alarm indicates if an optical signal is detected on the line t… |
| 1.3.6.1.4.1.20044.22.2.3.3.211 | Tablepm1001lhrAlmlineXfp1AlarmsTable | not-accessible | current | List of pm1001lhrAlmlineXfp1Alarms Article |
| 1.3.6.1.4.1.20044.22.2.3.3.211.1 | Rowpm1001lhrAlmlineXfp1AlarmsEntry | not-accessible | current | Row definition for the pm1001lhrAlmlineXfp1Alarms table |
| 1.3.6.1.4.1.20044.22.2.3.3.211.1.1 | Columnpm1001lhrAlmlineXfp1AlarmsIndex | read-only | current | Index definition for the pm1001lhrAlmlineXfp1Alarms table |
| 1.3.6.1.4.1.20044.22.2.3.3.211.1.3 | Columnpm1001lhrAlmModNrPortn | read-only | current | Line Optical Module Not Ready :This OID indicates that the module is unable to determine correct data. <Help> This alarm indicates if the line transceiver is r… |
| 1.3.6.1.4.1.20044.22.2.3.3.211.1.4 | Columnpm1001lhrAlmRxCdrNotLockedPortn | read-only | current | Line Optical Rx CDR Unlocked :This OID indicates that a loss of lock on the receiving side CDR has been detected <Help> This alarm indicates if the Rx CDR is l… |
| 1.3.6.1.4.1.20044.22.2.3.3.211.1.6 | Columnpm1001lhrAlmRxNrPortn | read-only | current | Line Optical Rx Not Ready :This OID indicates that a condition has arisen leading to invalid data on the receiving side. <Help> This alarm indicates if the Rx … |
| 1.3.6.1.4.1.20044.22.2.3.3.211.1.7 | Columnpm1001lhrAlmTxCdrNotLockedPortn | read-only | current | Line Optical Tx CDR Unlocked :This OID indicates a loss of lock on the transmitting side CDR has been detected. <Help> This alarm indicates if the Tx CDR is lo… |
| 1.3.6.1.4.1.20044.22.2.3.3.211.1.8 | Columnpm1001lhrAlmTxFaultPortn | read-only | current | Line Optical Tx Failure :This OID indicates a fault condition on the laser detected by the safety syste <Help> This alarm indicates if the laser of the line tr… |
| 1.3.6.1.4.1.20044.22.2.3.3.211.1.9 | Columnpm1001lhrAlmTxNrPortn | read-only | current | Line Optical Tx Not Ready :This OID indicates a condition has arisen leading to invalid data on the transmitting side <Help> This alarm indicates if the Tx par… |
| 1.3.6.1.4.1.20044.22.2.3.3.211.1.15 | Columnpm1001lhrAlmWavelengthUnlockedPortn | read-only | current | Line Optical Tx Wavelength Unlocked :This OID indicates that the wavelength error is exceeding the manufacturer tolerance <Help> This alarm indicates if the wa… |
| 1.3.6.1.4.1.20044.22.2.3.3.211.1.16 | Columnpm1001lhrAlmTecFaultPortn | read-only | current | Line Optical Tx Temp Regul Failed :This OID indicates a failure on the TEC module <Help> This alarm indicates if the TEC of the line transceiver is in fail con… |
| 1.3.6.1.4.1.20044.22.2.3.3.211.1.17 | Columnpm1001lhrAlmApdSupplyFaultPortn | read-only | current | Line Rx Photodiode Power Failed :This OID indicates a failure on the APD power supply <Help> This alarm indicates if the APD power supply is in fail condition … |
| 1.3.6.1.4.1.20044.22.3 | Nodepm1001lhrmeasures | |||
| 1.3.6.1.4.1.20044.22.3.1 | Nodepm1001lhrMesrOther | |||
| 1.3.6.1.4.1.20044.22.3.1.0 | Scalarpm1001lhrMesrsynth0 | read-only | deprecated | Not Used :This OID gives the unit used on AUX1 measurement of XFP#1 (Unit = ) |
| 1.3.6.1.4.1.20044.22.3.1.1 | Scalarpm1001lhrMesrsynth1 | read-only | deprecated | Not Used :This OID gives the unit used on AUX2 measurement of XFP#1 (Unit = ) |
| 1.3.6.1.4.1.20044.22.3.2 | Nodepm1001lhrMesrClient | |||
| 1.3.6.1.4.1.20044.22.3.3 | Nodepm1001lhrMesrLine | |||
| 1.3.6.1.4.1.20044.22.3.3.208 | Tablepm1001lhrMesrxfp1LxModTempMeasTable | not-accessible | current | List of pm1001lhrMesrxfp1LxModTempMeas Article |
| 1.3.6.1.4.1.20044.22.3.3.208.1 | Rowpm1001lhrMesrxfp1LxModTempMeasEntry | not-accessible | current | Row definition for the pm1001lhrMesrxfp1LxModTempMeas table |
| 1.3.6.1.4.1.20044.22.3.3.208.1.1 | Columnpm1001lhrMesrxfp1LxModTempMeasIndex | read-only | current | Index definition for the pm1001lhrMesrxfp1LxModTempMeas table |
| 1.3.6.1.4.1.20044.22.3.3.208.1.2 | Columnpm1001lhrMesrxfp1LxModTempMeasPortn | read-only | current | Line Optical Module Temperature :This OID gives the temperature of the XFP or OTX plugged in line#n, read from the DDM (Digital Diagnostic Monitoring) (Tempera… |
| 1.3.6.1.4.1.20044.22.3.3.209 | Tablepm1001lhrMesrxfp1ReservedTable | not-accessible | deprecated | List of pm1001lhrMesrxfp1Reserved Article |
| 1.3.6.1.4.1.20044.22.3.3.209.1 | Rowpm1001lhrMesrxfp1ReservedEntry | not-accessible | deprecated | Row definition for the pm1001lhrMesrxfp1Reserved table |
| 1.3.6.1.4.1.20044.22.3.3.209.1.1 | Columnpm1001lhrMesrxfp1ReservedIndex | read-only | deprecated | Index definition for the pm1001lhrMesrxfp1Reserved table |
| 1.3.6.1.4.1.20044.22.3.3.209.1.2 | Columnpm1001lhrMesrxfp1ReservedPortn | read-only | deprecated | Not Used :Reserved |
| 1.3.6.1.4.1.20044.22.3.3.210 | Tablepm1001lhrMesrxfp1LoBiasCurrentMeasTable | not-accessible | current | List of pm1001lhrMesrxfp1LoBiasCurrentMeas Article |
| 1.3.6.1.4.1.20044.22.3.3.210.1 | Rowpm1001lhrMesrxfp1LoBiasCurrentMeasEntry | not-accessible | current | Row definition for the pm1001lhrMesrxfp1LoBiasCurrentMeas table |
| 1.3.6.1.4.1.20044.22.3.3.210.1.1 | Columnpm1001lhrMesrxfp1LoBiasCurrentMeasIndex | read-only | current | Index definition for the pm1001lhrMesrxfp1LoBiasCurrentMeas table |
| 1.3.6.1.4.1.20044.22.3.3.210.1.2 | Columnpm1001lhrMesrxfp1LoBiasCurrentMeasPortn | read-only | current | Line Optical Module Laser Bias :This OID gives the bias value of the XFP or OTX plugged in line #n, read from the DDM (Digital Diagnostic Monitoring) (Bias = A… |
| 1.3.6.1.4.1.20044.22.3.3.211 | Tablepm1001lhrMesrxfp1LoTxPowerMeasTable | not-accessible | current | List of pm1001lhrMesrxfp1LoTxPowerMeas Article |
| 1.3.6.1.4.1.20044.22.3.3.211.1 | Rowpm1001lhrMesrxfp1LoTxPowerMeasEntry | not-accessible | current | Row definition for the pm1001lhrMesrxfp1LoTxPowerMeas table |
| 1.3.6.1.4.1.20044.22.3.3.211.1.1 | Columnpm1001lhrMesrxfp1LoTxPowerMeasIndex | read-only | current | Index definition for the pm1001lhrMesrxfp1LoTxPowerMeas table |
| 1.3.6.1.4.1.20044.22.3.3.211.1.2 | Columnpm1001lhrMesrxfp1LoTxPowerMeasPortn | read-only | current | Line Optical Module Tx Power :This OID gives the transmit power value of the XFP or OTX plugged in line #n, read from the DDM (Digital Diagnostic Monitoring) (… |
| 1.3.6.1.4.1.20044.22.3.3.212 | Tablepm1001lhrMesrxfp1LiRxPowerMeasTable | not-accessible | current | List of pm1001lhrMesrxfp1LiRxPowerMeas Article |
| 1.3.6.1.4.1.20044.22.3.3.212.1 | Rowpm1001lhrMesrxfp1LiRxPowerMeasEntry | not-accessible | current | Row definition for the pm1001lhrMesrxfp1LiRxPowerMeas table |
| 1.3.6.1.4.1.20044.22.3.3.212.1.1 | Columnpm1001lhrMesrxfp1LiRxPowerMeasIndex | read-only | current | Index definition for the pm1001lhrMesrxfp1LiRxPowerMeas table |
| 1.3.6.1.4.1.20044.22.3.3.212.1.2 | Columnpm1001lhrMesrxfp1LiRxPowerMeasPortn | read-only | current | Line Optical Module Rx Power :This OID gives the receive power value of the XFP or OTX plugged in line #n, read from the DDM (Digital Diagnostic Monitoring) (P… |
| 1.3.6.1.4.1.20044.22.3.3.213 | Tablepm1001lhrMesrxfp1LxAux1MeasTable | not-accessible | deprecated | List of pm1001lhrMesrxfp1LxAux1Meas Article |
| 1.3.6.1.4.1.20044.22.3.3.213.1 | Rowpm1001lhrMesrxfp1LxAux1MeasEntry | not-accessible | deprecated | Row definition for the pm1001lhrMesrxfp1LxAux1Meas table |
| 1.3.6.1.4.1.20044.22.3.3.213.1.1 | Columnpm1001lhrMesrxfp1LxAux1MeasIndex | read-only | deprecated | Index definition for the pm1001lhrMesrxfp1LxAux1Meas table |
| 1.3.6.1.4.1.20044.22.3.3.213.1.2 | Columnpm1001lhrMesrxfp1LxAux1MeasPortn | read-only | deprecated | Not Used :This OID gives the receive power value read in the DDM (Digital Diagnostic Monitoring) of the XFP or OTX plugged in line #n (Unit = ?) |
| 1.3.6.1.4.1.20044.22.3.3.214 | Tablepm1001lhrMesrxfp1LxAux2MeasTable | not-accessible | deprecated | List of pm1001lhrMesrxfp1LxAux2Meas Article |
| 1.3.6.1.4.1.20044.22.3.3.214.1 | Rowpm1001lhrMesrxfp1LxAux2MeasEntry | not-accessible | deprecated | Row definition for the pm1001lhrMesrxfp1LxAux2Meas table |
| 1.3.6.1.4.1.20044.22.3.3.214.1.1 | Columnpm1001lhrMesrxfp1LxAux2MeasIndex | read-only | deprecated | Index definition for the pm1001lhrMesrxfp1LxAux2Meas table |
| 1.3.6.1.4.1.20044.22.3.3.214.1.2 | Columnpm1001lhrMesrxfp1LxAux2MeasPortn | read-only | deprecated | Not Used :This OID gives the receive power value read in the DDM (Digital Diagnostic Monitoring) of the XFP or OTX plugged in line #n (Unit = ?) |
| 1.3.6.1.4.1.20044.22.3.3.224 | Tablepm1001lhrMesrotx1AgingTable | not-accessible | current | List of pm1001lhrMesrotx1Aging Article |
| 1.3.6.1.4.1.20044.22.3.3.224.1 | Rowpm1001lhrMesrotx1AgingEntry | not-accessible | current | Row definition for the pm1001lhrMesrotx1Aging table |
| 1.3.6.1.4.1.20044.22.3.3.224.1.1 | Columnpm1001lhrMesrotx1AgingIndex | read-only | current | Index definition for the pm1001lhrMesrotx1Aging table |
| 1.3.6.1.4.1.20044.22.3.3.224.1.2 | Columnpm1001lhrMesrotx1AgingPortn | read-only | current | Line OTX TLH Aging :This OID gives the aging of the Line OTX TLH, read from the DDM (Digital Diagnostic Monitoring) (Aging = AV) (Unit = %) <Help> This measure… |
| 1.3.6.1.4.1.20044.22.3.3.225 | Tablepm1001lhrMesrotx1LaserTemperatureTable | not-accessible | deprecated | List of pm1001lhrMesrotx1LaserTemperature Article |
| 1.3.6.1.4.1.20044.22.3.3.225.1 | Rowpm1001lhrMesrotx1LaserTemperatureEntry | not-accessible | deprecated | Row definition for the pm1001lhrMesrotx1LaserTemperature table |
| 1.3.6.1.4.1.20044.22.3.3.225.1.1 | Columnpm1001lhrMesrotx1LaserTemperatureIndex | read-only | deprecated | Index definition for the pm1001lhrMesrotx1LaserTemperature table |
| 1.3.6.1.4.1.20044.22.3.3.225.1.2 | Columnpm1001lhrMesrotx1LaserTemperaturePortn | read-only | deprecated | Line OTX TLH Laser Temperature :This OID gives the laser temperature of the Line OTX TLH, read from the DDM (Digital Diagnostic Monitoring) (Temperature = AV/2… |
| 1.3.6.1.4.1.20044.22.3.3.226 | Tablepm1001lhrMesrotx1FreqDeviationTable | not-accessible | current | List of pm1001lhrMesrotx1FreqDeviation Article |
| 1.3.6.1.4.1.20044.22.3.3.226.1 | Rowpm1001lhrMesrotx1FreqDeviationEntry | not-accessible | current | Row definition for the pm1001lhrMesrotx1FreqDeviation table |
| 1.3.6.1.4.1.20044.22.3.3.226.1.1 | Columnpm1001lhrMesrotx1FreqDeviationIndex | read-only | current | Index definition for the pm1001lhrMesrotx1FreqDeviation table |
| 1.3.6.1.4.1.20044.22.3.3.226.1.2 | Columnpm1001lhrMesrotx1FreqDeviationPortn | read-only | current | Line OTX TLH Frequency Deviation :This OID gives the frequency deviation of the Line OTX TLH, read from the DDM (Digital Diagnostic Monitoring) (Deviation = (A… |
| 1.3.6.1.4.1.20044.22.3.3.227 | Tablepm1001lhrMesrotx1LaserWvlengthTable | not-accessible | current | List of pm1001lhrMesrotx1LaserWvlength Article |
| 1.3.6.1.4.1.20044.22.3.3.227.1 | Rowpm1001lhrMesrotx1LaserWvlengthEntry | not-accessible | current | Row definition for the pm1001lhrMesrotx1LaserWvlength table |
| 1.3.6.1.4.1.20044.22.3.3.227.1.1 | Columnpm1001lhrMesrotx1LaserWvlengthIndex | read-only | current | Index definition for the pm1001lhrMesrotx1LaserWvlength table |
| 1.3.6.1.4.1.20044.22.3.3.227.1.2 | Columnpm1001lhrMesrotx1LaserWvlengthPortn | read-only | current | Line Optical Module Wavelength :This OID gives the laser wavelength of the Line OTX TLH, read from the DDM (Digital Diagnostic Monitoring) (Wavelength=29979245… |
| 1.3.6.1.4.1.20044.22.4 | Nodepm1001lhrcounters | |||
| 1.3.6.1.4.1.20044.22.4.1 | Nodepm1001lhrCntOther | |||
| 1.3.6.1.4.1.20044.22.4.2 | Nodepm1001lhrCntClient | |||
| 1.3.6.1.4.1.20044.22.4.3 | Nodepm1001lhrCntLine | |||
| 1.3.6.1.4.1.20044.22.4.3.152 | Tablepm1001lhrCntdfrmB1ErrCntTable | not-accessible | current | List of pm1001lhrCntdfrmB1ErrCnt Article |
| 1.3.6.1.4.1.20044.22.4.3.152.1 | Rowpm1001lhrCntdfrmB1ErrCntEntry | not-accessible | current | Row definition for the pm1001lhrCntdfrmB1ErrCnt table |
| 1.3.6.1.4.1.20044.22.4.3.152.1.1 | Columnpm1001lhrCntdfrmB1ErrCntIndex | read-only | current | Index definition for the pm1001lhrCntdfrmB1ErrCnt table |
| 1.3.6.1.4.1.20044.22.4.3.152.1.2 | Columnpm1001lhrCntdfrmB1ErrCntValuePortn | read-only | current | Line Input SM-BIP8 Errors :This counter is incremented each time a B1 error is detected on the Deframer input stream. <Help> This counter gives the number of B… |
| 1.3.6.1.4.1.20044.22.4.3.152.1.3 | Columnpm1001lhrCntdfrmB1ErrCntErrorPortn | read-only | current | Line Counter Error :This OID when set indicates the B1 error counter value is invalid on Port |
| 1.3.6.1.4.1.20044.22.4.3.152.1.4 | Columnpm1001lhrCntdfrmB1ErrCntOverloadPortn | read-only | current | Line Counter Overload :This OID when set indicates a B1 error counter overload on Port |
| 1.3.6.1.4.1.20044.22.4.3.153 | Tablepm1001lhrCntdfrmTimCntTable | not-accessible | current | List of pm1001lhrCntdfrmTimCnt Article |
| 1.3.6.1.4.1.20044.22.4.3.153.1 | Rowpm1001lhrCntdfrmTimCntEntry | not-accessible | current | Row definition for the pm1001lhrCntdfrmTimCnt table |
| 1.3.6.1.4.1.20044.22.4.3.153.1.1 | Columnpm1001lhrCntdfrmTimCntIndex | read-only | current | Index definition for the pm1001lhrCntdfrmTimCnt table |
| 1.3.6.1.4.1.20044.22.4.3.153.1.2 | Columnpm1001lhrCntdfrmTimCntValuePortn | read-only | current | Line Timer Counter :This is the timing counter dedicated to the downstream deframer counters. It is incremented every 125 us. |
| 1.3.6.1.4.1.20044.22.4.3.153.1.3 | Columnpm1001lhrCntdfrmTimCntErrorPortn | read-only | current | Line Counter Error :This OID when set indicates the deframer timer counter value is invalid on Port |
| 1.3.6.1.4.1.20044.22.4.3.153.1.4 | Columnpm1001lhrCntdfrmTimCntOverloadPortn | read-only | current | Line Counter Overload :This OID when set indicates a deframer timer counter overload on Port |
| 1.3.6.1.4.1.20044.22.4.3.154 | Tablepm1001lhrCntdfrmPrimLineErrCntTable | not-accessible | current | List of pm1001lhrCntdfrmPrimLineErrCnt Article |
| 1.3.6.1.4.1.20044.22.4.3.154.1 | Rowpm1001lhrCntdfrmPrimLineErrCntEntry | not-accessible | current | Row definition for the pm1001lhrCntdfrmPrimLineErrCnt table |
| 1.3.6.1.4.1.20044.22.4.3.154.1.1 | Columnpm1001lhrCntdfrmPrimLineErrCntIndex | read-only | current | Index definition for the pm1001lhrCntdfrmPrimLineErrCnt table |
| 1.3.6.1.4.1.20044.22.4.3.154.1.2 | Columnpm1001lhrCntdfrmPrimLineErrCntValuePortn | read-only | current | Line Input FEC Corrected Errors :This counter is incremented each time the FEC is correcting an error on the line input stream. <Help> This counter gives the n… |
| 1.3.6.1.4.1.20044.22.4.3.154.1.3 | Columnpm1001lhrCntdfrmPrimLineErrCntErrorPortn | read-only | current | FEC Counter Error :This bit when set indicates the FEC corrected errors counter value is invalid on Line |
| 1.3.6.1.4.1.20044.22.4.3.154.1.4 | Columnpm1001lhrCntdfrmPrimLineErrCntOverloadPortn | read-only | current | FEC Counter Overload :This bit when set indicates a FEC corrected errors counter overload on Line |
| 1.3.6.1.4.1.20044.22.4.259 | Scalarpm1001lhrCntCountersReset | read-write | current | Counters Reset:This OID resets and restarts all the counters |
| 1.3.6.1.4.1.20044.22.4.260 | Scalarpm1001lhrCntCountersStop | read-write | current | Counters stop:This OID stops all the counters |
| 1.3.6.1.4.1.20044.22.6 | Nodepm1001lhrcontrolsWrite | |||
| 1.3.6.1.4.1.20044.22.6.1 | Nodepm1001lhrCtrlOther | |||
| 1.3.6.1.4.1.20044.22.6.1.1 | Nodepm1001lhrCtrlconfMgnt1 | |||
| 1.3.6.1.4.1.20044.22.6.1.1.1 | Scalarpm1001lhrCtrlConf1Load1 | read-write | current | Load Configuration Tables Set Nb 1 :When set this OID enables loading from flash configuration1 into the PM. |
| 1.3.6.1.4.1.20044.22.6.1.1.2 | Scalarpm1001lhrCtrlConf2Load1 | read-write | current | Load Configuration Tables Set Nb 2 :When set this OID enables loading from flash configuration2 into the PM. |
| 1.3.6.1.4.1.20044.22.6.1.1.10 | Scalarpm1001lhrCtrlConf2Flash1 | read-write | current | Write Configuration Tables :This OID saves the current configuration of the PM as configuration2 in the flash. <Help> This control saves the customer configura… |
| 1.3.6.1.4.1.20044.22.6.1.1.14 | Scalarpm1001lhrCtrlConf2Clear1 | read-write | current | Clear Configuration Tables :This OID clears the configuration tables from configuration2 in the flash. <Help> This control restores the default configuration o… |
| 1.3.6.1.4.1.20044.22.6.1.4 | Nodepm1001lhrCtrlsynth4 | |||
| 1.3.6.1.4.1.20044.22.6.1.4.1 | Scalarpm1001lhrCtrlCorrelatOn | read-write | current | Enable Alarm Correlation :This OID enables the alarm correlation in the PM. |
| 1.3.6.1.4.1.20044.22.6.1.4.2 | Scalarpm1001lhrCtrlCorrelatOff | read-write | current | Disable Alarm Correlation :This OID disables the alarm correlation in the PM. |
| 1.3.6.1.4.1.20044.22.6.1.5 | Nodepm1001lhrCtrlswMgnt | |||
| 1.3.6.1.4.1.20044.22.6.1.5.2 | Scalarpm1001lhrCtrlColdReset | read-write | current | PM Cold Reset :This OID, when set, causes a cold reset of the PM. This reset is traffic affecting, and the configuration of PM is reloaded on start-up. <Help> … |
| 1.3.6.1.4.1.20044.22.6.1.5.3 | Scalarpm1001lhrCtrlWarmReset | read-write | current | PM Warm Reset :This OID, when set, causes a warm reset of the PM. This reset is not traffic affecting, and the configuration of PM remains unchanged. <Help> Th… |
| 1.3.6.1.4.1.20044.22.6.1.5.5 | Scalarpm1001lhrCtrlLoadSwBank1 | read-write | current | Set Software Nb 1 As Active :This OID, when set, loads the SW from bank1 into the PM. It must be followed by a reset. <Help> This controls selects the first SW… |
| 1.3.6.1.4.1.20044.22.6.1.5.6 | Scalarpm1001lhrCtrlLoadSwBank2 | read-write | current | Set Software Nb 2 As Active :This OID, when set, loads the SW from bank2 into the PM. It must be followed by a reset. <Help> This controls selects the second S… |
| 1.3.6.1.4.1.20044.22.6.1.6 | Nodepm1001lhrCtrlgwMgnt | |||
| 1.3.6.1.4.1.20044.22.6.1.6.1 | Scalarpm1001lhrCtrlCurrentGwReset | read-write | current | Active Gateware Reset :This OID, when set, resets the active gateware. It is traffic affecting. |
| 1.3.6.1.4.1.20044.22.6.1.6.5 | Scalarpm1001lhrCtrlLoadGwBank1 | read-write | current | Set Gateware Nb 1 As Active :This OID, when set, loads the GW from bank1 (Flash) into the PM. It is followed by an automatic gateware cold reset. <Help> This c… |
| 1.3.6.1.4.1.20044.22.6.1.6.6 | Scalarpm1001lhrCtrlLoadGwBank2 | read-write | current | Set Gateware Nb 2 As Active :This OID, when set, loads the GW from bank2 (Flash) into the PM. It is followed by an automatic gateware cold reset. |
| 1.3.6.1.4.1.20044.22.6.1.6.7 | Scalarpm1001lhrCtrlLoadGwBank3 | read-write | current | Set Gateware Nb 3 As Active :This OID, when set, loads the GW from bank3 (Flash) into the PM. It is followed by an automatic gateware cold reset. <Help> This c… |
| 1.3.6.1.4.1.20044.22.6.1.6.8 | Scalarpm1001lhrCtrlLoadGwBank4 | read-write | current | Set Gateware Nb 4 As Active :This OID, when set, loads the GW from bank4 (Flash) into the PM. It is followed by an automatic gateware cold reset. |
| 1.3.6.1.4.1.20044.22.6.1.192 | Nodepm1001lhrCtrlledTest | |||
| 1.3.6.1.4.1.20044.22.6.1.192.1 | Scalarpm1001lhrCtrlGreenLed | read-write | current | Green Leds Test :This OID switches on all the green Leds as a test feature. <Help> This control initiates a test leds turning all the LEDs to green |
| 1.3.6.1.4.1.20044.22.6.1.192.2 | Scalarpm1001lhrCtrlRedLed | read-write | current | Red Leds Test :This OID switches on all the red Leds as a test feature. <Help> This control initiates a test leds turning all the LEDs to red |
| 1.3.6.1.4.1.20044.22.6.1.192.3 | Scalarpm1001lhrCtrlLedOff | read-write | current | Leds Off :This OID switches off all the Leds as a test feature. <Help> This control initiates a test leds turning all the LEDs to OFF |
| 1.3.6.1.4.1.20044.22.6.1.193 | Nodepm1001lhrCtrlmoduleOosMode | |||
| 1.3.6.1.4.1.20044.22.6.1.193.1 | Scalarpm1001lhrCtrlModuleOosMode | read-write | current | PM Out Of Service :This OID sets the PM1008 Out Of Service <Help> This control defines the service state of the complete module |
| 1.3.6.1.4.1.20044.22.6.2 | Nodepm1001lhrCtrlClient | |||
| 1.3.6.1.4.1.20044.22.6.2.16 | Tablepm1001lhrCtrlaccessLoopTable | not-accessible | current | List of pm1001lhrCtrlaccessLoop Article |
| 1.3.6.1.4.1.20044.22.6.2.16.1 | Rowpm1001lhrCtrlaccessLoopEntry | not-accessible | current | Row definition for the pm1001lhrCtrlaccessLoop table |
| 1.3.6.1.4.1.20044.22.6.2.16.1.1 | Columnpm1001lhrCtrlaccessLoopIndex | read-only | current | Index definition for the pm1001lhrCtrlaccessLoop table |
| 1.3.6.1.4.1.20044.22.6.2.16.1.2 | Columnpm1001lhrCtrlaccessLoopPortn | read-write | current | Client Facility Loopback :This OID operates a Client Facility Loopback, looping client input signal on the client output port. The loop is located on the clien… |
| 1.3.6.1.4.1.20044.22.6.2.26 | Tablepm1001lhrCtrlclientAccessTermLoopTable | not-accessible | current | List of pm1001lhrCtrlclientAccessTermLoop Article |
| 1.3.6.1.4.1.20044.22.6.2.26.1 | Rowpm1001lhrCtrlclientAccessTermLoopEntry | not-accessible | current | Row definition for the pm1001lhrCtrlclientAccessTermLoop table |
| 1.3.6.1.4.1.20044.22.6.2.26.1.1 | Columnpm1001lhrCtrlclientAccessTermLoopIndex | read-only | current | Index definition for the pm1001lhrCtrlclientAccessTermLoop table |
| 1.3.6.1.4.1.20044.22.6.2.26.1.2 | Columnpm1001lhrCtrlclientAccessTermLoopPortn | read-write | current | Client Terminal Loopback :This OID operates a Client Terminal Loopback, looping client input signal on the client output port. The loop is located on the line … |
| 1.3.6.1.4.1.20044.22.6.3 | Nodepm1001lhrCtrlLine | |||
| 1.3.6.1.4.1.20044.22.6.3.52 | Scalarpm1001lhrCtrlprotocol | read-write | current | Client Protocol :This OID sets the protocol on the PM |
| 1.3.6.1.4.1.20044.22.6.3.69 | Tablepm1001lhrCtrlfecDisableTable | not-accessible | current | List of pm1001lhrCtrlfecDisable Article |
| 1.3.6.1.4.1.20044.22.6.3.69.1 | Rowpm1001lhrCtrlfecDisableEntry | not-accessible | current | Row definition for the pm1001lhrCtrlfecDisable table |
| 1.3.6.1.4.1.20044.22.6.3.69.1.1 | Columnpm1001lhrCtrlfecDisableIndex | read-only | current | Index definition for the pm1001lhrCtrlfecDisable table |
| 1.3.6.1.4.1.20044.22.6.3.69.1.2 | Columnpm1001lhrCtrlfecDisablePortn | read-write | current | Forward Error Correction Inhibition :This OID, when set, inhibits the Forward Error Correction feature on the line input <Help> This control disables the Forwa… |
| 1.3.6.1.4.1.20044.22.6.3.74 | Tablepm1001lhrCtrllineOosModeTable | not-accessible | current | List of pm1001lhrCtrllineOosMode Article |
| 1.3.6.1.4.1.20044.22.6.3.74.1 | Rowpm1001lhrCtrllineOosModeEntry | not-accessible | current | Row definition for the pm1001lhrCtrllineOosMode table |
| 1.3.6.1.4.1.20044.22.6.3.74.1.1 | Columnpm1001lhrCtrllineOosModeIndex | read-only | current | Index definition for the pm1001lhrCtrllineOosMode table |
| 1.3.6.1.4.1.20044.22.6.3.74.1.2 | Columnpm1001lhrCtrllineOosModePortn | read-write | current | Line Port Out Of Service :This OID sets the line port Out Of Service |
| 1.3.6.1.4.1.20044.22.6.3.208 | Tablepm1001lhrCtrlxfpOnoffTable | not-accessible | current | List of pm1001lhrCtrlxfpOnoff Article |
| 1.3.6.1.4.1.20044.22.6.3.208.1 | Rowpm1001lhrCtrlxfpOnoffEntry | not-accessible | current | Row definition for the pm1001lhrCtrlxfpOnoff table |
| 1.3.6.1.4.1.20044.22.6.3.208.1.1 | Columnpm1001lhrCtrlxfpOnoffIndex | read-only | current | Index definition for the pm1001lhrCtrlxfpOnoff table |
| 1.3.6.1.4.1.20044.22.6.3.208.1.2 | Columnpm1001lhrCtrlxfpOnoffPortn | read-write | current | Line Optical Laser Shutdown :This OID switches off the XFP or the OTX <Help> This control defines the laser state of the line transceiver |
| 1.3.6.1.4.1.20044.22.6.3.209 | Tablepm1001lhrCtrlxfpLineLoopTable | not-accessible | current | List of pm1001lhrCtrlxfpLineLoop Article |
| 1.3.6.1.4.1.20044.22.6.3.209.1 | Rowpm1001lhrCtrlxfpLineLoopEntry | not-accessible | current | Row definition for the pm1001lhrCtrlxfpLineLoop table |
| 1.3.6.1.4.1.20044.22.6.3.209.1.1 | Columnpm1001lhrCtrlxfpLineLoopIndex | read-only | current | Index definition for the pm1001lhrCtrlxfpLineLoop table |
| 1.3.6.1.4.1.20044.22.6.3.209.1.2 | Columnpm1001lhrCtrlxfpLineLoopPortn | read-write | current | Line Facility Loopback :This OID operates a Line Facility Loopback, looping line input signal on the line output port. The loop is located on the line transcei… |
| 1.3.6.1.4.1.20044.22.6.3.210 | Tablepm1001lhrCtrlxfpXfiLoopTable | not-accessible | current | List of pm1001lhrCtrlxfpXfiLoop Article |
| 1.3.6.1.4.1.20044.22.6.3.210.1 | Rowpm1001lhrCtrlxfpXfiLoopEntry | not-accessible | current | Row definition for the pm1001lhrCtrlxfpXfiLoop table |
| 1.3.6.1.4.1.20044.22.6.3.210.1.1 | Columnpm1001lhrCtrlxfpXfiLoopIndex | read-only | current | Index definition for the pm1001lhrCtrlxfpXfiLoop table |
| 1.3.6.1.4.1.20044.22.6.3.210.1.2 | Columnpm1001lhrCtrlxfpXfiLoopPortn | read-write | current | Line Terminal Loopback :This OID operates a Line Terminal Loopback, looping line input signal on the line output port. The loop is located on all client transc… |
| 1.3.6.1.4.1.20044.22.6.3.212 | Tablepm1001lhrCtrllineTunableChannelTable | not-accessible | current | List of pm1001lhrCtrllineTunableChannel Article |
| 1.3.6.1.4.1.20044.22.6.3.212.1 | Rowpm1001lhrCtrllineTunableChannelEntry | not-accessible | current | Row definition for the pm1001lhrCtrllineTunableChannel table |
| 1.3.6.1.4.1.20044.22.6.3.212.1.1 | Columnpm1001lhrCtrllineTunableChannelIndex | read-only | current | Index definition for the pm1001lhrCtrllineTunableChannel table |
| 1.3.6.1.4.1.20044.22.6.3.212.1.2 | Columnpm1001lhrCtrllineTunableChannelPortn | read-write | current | ITU Channel :This OID selects the ITU channel of the Line OTX TLH Laser <Help> This control defines the ITU channel of the Line OTX TLH Laser |
| 1.3.6.1.4.1.20044.22.6.3.213 | Tablepm1001lhrCtrllinePhotodiodeModeTable | not-accessible | current | List of pm1001lhrCtrllinePhotodiodeMode Article |
| 1.3.6.1.4.1.20044.22.6.3.213.1 | Rowpm1001lhrCtrllinePhotodiodeModeEntry | not-accessible | current | Row definition for the pm1001lhrCtrllinePhotodiodeMode table |
| 1.3.6.1.4.1.20044.22.6.3.213.1.1 | Columnpm1001lhrCtrllinePhotodiodeModeIndex | read-only | current | Index definition for the pm1001lhrCtrllinePhotodiodeMode table |
| 1.3.6.1.4.1.20044.22.6.3.213.1.2 | Columnpm1001lhrCtrllinePhotodiodeModePortn | read-write | current | OTX TLH Rx Sens. Mode :This OID defines the Rx sensiblity mode of the Line OTX TLH <Help> This control defines the receiver sensibility mode of the Line OTX TL… |
| 1.3.6.1.4.1.20044.22.6.3.214 | Tablepm1001lhrCtrllinePhotodiodeValueTable | not-accessible | current | List of pm1001lhrCtrllinePhotodiodeValue Article |
| 1.3.6.1.4.1.20044.22.6.3.214.1 | Rowpm1001lhrCtrllinePhotodiodeValueEntry | not-accessible | current | Row definition for the pm1001lhrCtrllinePhotodiodeValue table |
| 1.3.6.1.4.1.20044.22.6.3.214.1.1 | Columnpm1001lhrCtrllinePhotodiodeValueIndex | read-only | current | Index definition for the pm1001lhrCtrllinePhotodiodeValue table |
| 1.3.6.1.4.1.20044.22.6.3.214.1.2 | Columnpm1001lhrCtrllinePhotodiodeValuePortn | read-write | current | OTX TLH Rx Sensibility :This OID sets the Rx sensibility of the Line OTX TLH (custom mode only) <Help> This control defines the receiver sensibility value (onl… |
| 1.3.6.1.4.1.20044.22.6.3.215 | Tablepm1001lhrCtrllinePowerLaserTable | not-accessible | current | List of pm1001lhrCtrllinePowerLaser Article |
| 1.3.6.1.4.1.20044.22.6.3.215.1 | Rowpm1001lhrCtrllinePowerLaserEntry | not-accessible | current | Row definition for the pm1001lhrCtrllinePowerLaser table |
| 1.3.6.1.4.1.20044.22.6.3.215.1.1 | Columnpm1001lhrCtrllinePowerLaserIndex | read-only | current | Index definition for the pm1001lhrCtrllinePowerLaser table |
| 1.3.6.1.4.1.20044.22.6.3.215.1.2 | Columnpm1001lhrCtrllinePowerLaserPortn | read-write | current | Line Laser Output Power [3-5] :This OID sets the output power value on the laser of the Line OTX TLH (AV=Power*10+158) (Unit = dBm) <Help> This control defines… |
| 1.3.6.1.4.1.20044.22.7 | Nodepm1001lhrri | |||
| 1.3.6.1.4.1.20044.22.7.1 | Nodepm1001lhrriTable | |||
| 1.3.6.1.4.1.20044.22.7.1.1 | Tablepm1001lhrRinvLineTable | not-accessible | current | List of the XFPs on the selected module |
| 1.3.6.1.4.1.20044.22.7.1.1.1 | Rowpm1001lhrRinvLineEntry | not-accessible | current | Row definition for the XFP table |
| 1.3.6.1.4.1.20044.22.7.1.1.1.1 | Columnpm1001lhrRinvLineIndex | read-only | current | Index for XFP table |
| 1.3.6.1.4.1.20044.22.7.1.1.1.2 | Columnpm1001lhrRinvxfpLine | read-only | current | Inventory for the XFP: This OID contains the inventory for the XFP |
| 1.3.6.1.4.1.20044.22.7.2 | Scalarpm1001lhrRinvReloadInventory | read-write | current | Reload the inventory: This OID triggers an inventory reload. |
| 1.3.6.1.4.1.20044.22.7.3 | Scalarpm1001lhrRinvHwPlatform | read-only | current | HW platform description: This OID contains the description of the Hardware platform. |
| 1.3.6.1.4.1.20044.22.7.4 | Scalarpm1001lhrRinvModulePlatform | read-only | current | Module platform description: This OID contains the description of the Module. |
| 1.3.6.1.4.1.20044.22.7.5 | Scalarpm1001lhrRinvSwPlatform | read-only | current | SW platform description: This OID contains the description of the Software platform. |
| 1.3.6.1.4.1.20044.22.7.6 | Scalarpm1001lhrRinvGwPlatform | read-only | current | GW platform desciption: This OID contains the description of the Gateware platform. |
| 1.3.6.1.4.1.20044.22.8 | Nodepm1001lhrdownload | |||
| 1.3.6.1.4.1.20044.22.8.1 | Nodepm1001lhrDwlOther | |||
| 1.3.6.1.4.1.20044.22.8.1.0 | Nodepm1001lhrDwlrestartProcess | |||
| 1.3.6.1.4.1.20044.22.8.1.0.1 | Scalarpm1001lhrDwlWarmRestartProcessed | read-only | current | Warm Restart :This OID indicates that the module last restart was a Warm RESTART |
| 1.3.6.1.4.1.20044.22.8.1.0.2 | Scalarpm1001lhrDwlColdRestartProcessed | read-only | current | Cold Restart :This OID indicates that the module last restart was a Cold RESTART |
| 1.3.6.1.4.1.20044.22.8.1.1 | Nodepm1001lhrDwlswBanksUsed | |||
| 1.3.6.1.4.1.20044.22.8.1.1.1 | Scalarpm1001lhrDwlSwBank1Used | read-only | current | SW bank 1 active :This OID indicates the module is working on SW bank 1 <Help> This status indicates if the SW bank 1 is active or standby |
| 1.3.6.1.4.1.20044.22.8.1.1.2 | Scalarpm1001lhrDwlSwBank2Used | read-only | current | SW bank 2 active :This OID indicates the module is working on SW bank 2 <Help> This status indicates if the SW bank 2 is active or standby |
| 1.3.6.1.4.1.20044.22.8.1.1.5 | Scalarpm1001lhrDwlSwBank1Notempty | read-only | current | SW bank 1 loaded :This OID indicates a software is loaded in SW bank 1 <Help> This status indicates if the SW bank 1 contains SW package |
| 1.3.6.1.4.1.20044.22.8.1.1.6 | Scalarpm1001lhrDwlSwBank2Notempty | read-only | current | SW bank 2 loaded :This OID indicates a software is loaded in SW bank 2 <Help> This status indicates if the SW bank 2 contains SW package |
| 1.3.6.1.4.1.20044.22.8.1.2 | Nodepm1001lhrDwlgwBanksUsed | |||
| 1.3.6.1.4.1.20044.22.8.1.2.1 | Scalarpm1001lhrDwlGwBank1Used | read-only | current | GW bank 1 active :This OID indicates the module is working on GW bank 1 <Help> This status indicates if the GW bank 1 is active or standby |
| 1.3.6.1.4.1.20044.22.8.1.2.2 | Scalarpm1001lhrDwlGwBank2Used | read-only | current | GW bank 2 active :This OID indicates the module is working on GW bank 2 |
| 1.3.6.1.4.1.20044.22.8.1.2.3 | Scalarpm1001lhrDwlGwBank3Used | read-only | current | GW bank 3 active :This OID indicates the module is working on GW bank 3 <Help> This status indicates if the GW bank 3 is active or standby |
| 1.3.6.1.4.1.20044.22.8.1.2.4 | Scalarpm1001lhrDwlGwBank4Used | read-only | current | GW bank 4 active :This OID indicates the module is working on GW bank 4 |
| 1.3.6.1.4.1.20044.22.8.1.2.5 | Scalarpm1001lhrDwlGwBank1Notempty | read-only | current | GW bank 1 loaded :This OID indicates a gateware is loaded in GW bank 1 <Help> This status indicates if the GW bank 1 contains GW package |
| 1.3.6.1.4.1.20044.22.8.1.2.6 | Scalarpm1001lhrDwlGwBank2Notempty | read-only | current | GW bank 2 loaded :This OID indicates a gateware is loaded in GW bank 2 |
| 1.3.6.1.4.1.20044.22.8.1.2.7 | Scalarpm1001lhrDwlGwBank3Notempty | read-only | current | GW bank 3 loaded :This OID indicates a gateware is loaded in GW bank 3 <Help> This status indicates if the GW bank 3 contains GW package |
| 1.3.6.1.4.1.20044.22.8.1.2.8 | Scalarpm1001lhrDwlGwBank4Notempty | read-only | current | GW bank 4 loaded :This OID indicates a gateware is loaded in GW bank 4 |
| 1.3.6.1.4.1.20044.22.8.2 | Nodepm1001lhrDwlClient | |||
| 1.3.6.1.4.1.20044.22.8.3 | Nodepm1001lhrDwlLine | |||
| 1.3.6.1.4.1.20044.22.9 | Nodepm1001lhrConfig | |||
| 1.3.6.1.4.1.20044.22.9.1 | Nodepm1001lhrCfgAccessCAisCsf | |||
| 1.3.6.1.4.1.20044.22.9.2 | Nodepm1001lhrCfgStartup | |||
| 1.3.6.1.4.1.20044.22.9.2.1 | Nodepm1001lhrtablelineStartup | |||
| 1.3.6.1.4.1.20044.22.9.2.1.2 | Scalarpm1001lhrCfgsystConfLine1 | read-write | current | Default Settings on Line 1 :This register configures the default initialisation settings on Line port 1. |
| 1.3.6.1.4.1.20044.22.9.2.1.3 | Scalarpm1001lhrCfgnetConfMod | read-write | current | Default Protocol on Module :This register configures the default initialisation protocol on the module. |
| 1.3.6.1.4.1.20044.22.9.2.1.5 | Scalarpm1001lhrCfglineOptions1 | read-write | current | Default Options on Active Line Port :This register configures the default options on the active line port |
| 1.3.6.1.4.1.20044.22.9.2.1.6 | Scalarpm1001lhrCfgsystConfLine2 | read-write | current | Default Settings on Line 2 :This register configures the default initialisation settings on Line port 2. |
| 1.3.6.1.4.1.20044.22.9.2.1.9 | Scalarpm1001lhrCfglineOptions2 | read-write | current | Default Options on Active Line Port :This register configures the default options on the active line port |
| 1.3.6.1.4.1.20044.22.9.2.2 | Tablepm1001lhrCfgXfpTable | not-accessible | current | List of Article |
| 1.3.6.1.4.1.20044.22.9.2.2.1 | Rowpm1001lhrCfgXfpEntry | not-accessible | current | Row definition for the startup table |
| 1.3.6.1.4.1.20044.22.9.2.2.1.1 | Columnpm1001lhrCfgXfpIndex | read-only | current | Index definition for the xfp table |
| 1.3.6.1.4.1.20044.22.9.2.2.1.3 | Columnpm1001lhrCfgSystConfXfpPortn | read-write | current | Default settings on XFP Port :This register configures the default initialisation settings on XFP port. |
| 1.3.6.1.4.1.20044.22.9.2.2.1.4 | Columnpm1001lhrCfgDataRateConfXfpPortn | read-write | deprecated | : |
| 1.3.6.1.4.1.20044.22.9.3 | Nodepm1001lhrCfgLabels | |||
| 1.3.6.1.4.1.20044.22.9.3.1 | Tablepm1001lhrCfgLabelclientTable | not-accessible | current | List of Article |
| 1.3.6.1.4.1.20044.22.9.3.1.1 | Rowpm1001lhrCfgLabelclientEntry | not-accessible | current | Row definition for the labels table |
| 1.3.6.1.4.1.20044.22.9.3.1.1.1 | Columnpm1001lhrCfgLabelclientIndex | read-only | current | Index definition for the labelclient table |
| 1.3.6.1.4.1.20044.22.9.3.1.1.3 | Columnpm1001lhrCfgLabelclientPortn | read-write | current | Default settings on the label of the Ports :These registers configures the default initialisation settings of the labels of the ports. |
| 1.3.6.1.4.1.20044.22.9.3.2 | Tablepm1001lhrCfgLabellineTable | not-accessible | current | List of Article |
| 1.3.6.1.4.1.20044.22.9.3.2.1 | Rowpm1001lhrCfgLabellineEntry | not-accessible | current | Row definition for the labels table |
| 1.3.6.1.4.1.20044.22.9.3.2.1.1 | Columnpm1001lhrCfgLabellineIndex | read-only | current | Index definition for the labelline table |
| 1.3.6.1.4.1.20044.22.9.3.2.1.3 | Columnpm1001lhrCfgLabellinePortn | read-write | current | Default settings on the label of the lines :These registers configures the default initialisation settings of the labels of the lines. |
| 1.3.6.1.4.1.20044.22.9.4 | Nodepm1001lhrCfgStartuptlh | |||
| 1.3.6.1.4.1.20044.22.9.4.1 | Tablepm1001lhrCfgOtxtlhTable | not-accessible | current | List of Article |
| 1.3.6.1.4.1.20044.22.9.4.1.1 | Rowpm1001lhrCfgOtxtlhEntry | not-accessible | current | Row definition for the startuptlh table |
| 1.3.6.1.4.1.20044.22.9.4.1.1.1 | Columnpm1001lhrCfgOtxtlhIndex | read-only | current | Index definition for the otxtlh table |
| 1.3.6.1.4.1.20044.22.9.4.1.1.3 | Columnpm1001lhrCfgNuPortn | read-write | deprecated | : |
| 1.3.6.1.4.1.20044.22.9.4.1.1.4 | Columnpm1001lhrCfgLineDitherRatePortn | read-write | current | Default Line OTX TLH FM amplitude :This register configures the start-up width of the frequency modulation of the Line OTX TLH |
| 1.3.6.1.4.1.20044.22.9.4.1.1.5 | Columnpm1001lhrCfgLineDitherFhzPortn | read-write | current | Default Line OTX TLH FM frequency :This register configures the start-up frequency of the frequency modulation of the Line OTX TLH |
| 1.3.6.1.4.1.20044.22.9.4.1.1.6 | Columnpm1001lhrCfgLinePwrLaserPortn | read-write | current | Defaut Line OTX TLH output Power :This register configures the start-up output power of the Line OTX TLH (Unit = dBm) |
| 1.3.6.1.4.1.20044.22.9.4.1.1.7 | Columnpm1001lhrCfgLineFCurrentPortn | read-write | current | Default Line OTX TLH Channel :This register configures the start-up laser channel of the Line OTX TLH |
| 1.3.6.1.4.1.20044.22.9.4.1.1.8 | Columnpm1001lhrCfgLineGridCurrentPortn | read-write | current | Default Line OTX TLH Grid :This register configures the start-up laser grid of the Line OTX TLH |
| 1.3.6.1.4.1.20044.22.9.4.1.1.9 | Columnpm1001lhrCfgFPortn | read-write | current | Default Line OTX TLH lowest Freq :This register configures the start-up lowest frequency supported on the Line OTX TLH |
| 1.3.6.1.4.1.20044.22.9.4.1.1.10 | Columnpm1001lhrCfgReservedPortn | read-write | deprecated | : |
| 1.3.6.1.4.1.20044.22.9.4.1.1.11 | Columnpm1001lhrCfgLinePhotodiodeModePortn | read-write | current | Default Line OTX TLH APD mode :This register configures the start-up APD mode of the Line OTX TLH |
| 1.3.6.1.4.1.20044.22.9.4.1.1.12 | Columnpm1001lhrCfgLinePhotodiodeValuePortn | read-write | current | Default Line OTX TLH APD atten. :This register configures the start-up APD attenuation on the Line OTX TLH |
| 1.3.6.1.4.1.20044.22.9.5 | Nodepm1001lhrCfgStartuptablefive | |||
| 1.3.6.1.4.1.20044.22.9.5.1 | Tablepm1001lhrCfgOtxtlhcapabilitiesTable | not-accessible | current | List of Article |
| 1.3.6.1.4.1.20044.22.9.5.1.1 | Rowpm1001lhrCfgOtxtlhcapabilitiesEntry | not-accessible | current | Row definition for the startuptablefive table |
| 1.3.6.1.4.1.20044.22.9.5.1.1.1 | Columnpm1001lhrCfgOtxtlhcapabilitiesIndex | read-only | current | Index definition for the otxtlhcapabilities table |
| 1.3.6.1.4.1.20044.22.9.5.1.1.3 | Columnpm1001lhrCfgComponentTypePortn | read-only | current | Component parameters :This OID defines the component parameters |
| 1.3.6.1.4.1.20044.22.9.5.1.1.4 | Columnpm1001lhrCfgMiscellaneousPortn | read-only | current | Miscellaneous default settings :This OID defines the miscellaneous parameters |
| 1.3.6.1.4.1.20044.22.9.5.1.1.5 | Columnpm1001lhrCfgFirstChannelPortn | read-only | current | Number of the first channel of the component :This OID defines the first channel number of the PM |
| 1.3.6.1.4.1.20044.22.9.5.1.1.6 | Columnpm1001lhrCfgLastChannelPortn | read-only | current | Number of the last channel of the component :This OID defines the last channel number of the PM |
| 1.3.6.1.4.1.20044.22.9.5.1.1.7 | Columnpm1001lhrCfgGridPortn | read-only | current | Grid value of the component :This OID defines the grid of the PM |
| 1.3.6.1.4.1.20044.22.9.257 | Scalarpm1001lhrCfgWriteConfiguration | read-write | current | Write configuration to module:This OID writes the complete configuration to the module |
| 1.3.6.1.4.1.20044.22.10 | Nodepm1001lhrtraps | |||
| 1.3.6.1.4.1.20044.22.10.3 | Scalarpm1001lhrtrapLineNumber | read-only | current | Last Line which generates a trap |
| 1.3.6.1.4.1.20044.22.10.4 | Scalarpm1001lhrtrapBoardNumber | read-only | current | Last module which generates a trap |
| 1.3.6.1.4.1.20044.22.10.30 | Notificationpm1001lhrLineTrapNotUrgentGoesOn | current | Not urgent Line default is activated | |
| 1.3.6.1.4.1.20044.22.10.31 | Notificationpm1001lhrLineTrapNotUrgentGoesOff | current | Not urgent Line default disappeared | |
| 1.3.6.1.4.1.20044.22.10.32 | Notificationpm1001lhrLineTrapUrgentGoesOn | current | Urgent Line default is activated | |
| 1.3.6.1.4.1.20044.22.10.33 | Notificationpm1001lhrLineTrapUrgentGoesOff | current | Urgent Line default disappeared | |
| 1.3.6.1.4.1.20044.22.10.34 | Notificationpm1001lhrLineTrapCritGoesOn | current | Critical Line default is activated | |
| 1.3.6.1.4.1.20044.22.10.35 | Notificationpm1001lhrLineTrapCritGoesOff | current | Critical Line default disappeared | |
| 1.3.6.1.4.1.20044.22.10.50 | Notificationpm1001lhrPowerTrapUrgentGoesOn | current | Urgent power supply default is activated | |
| 1.3.6.1.4.1.20044.22.10.51 | Notificationpm1001lhrPowerTrapUrgentGoesOff | current | Urgent power supply default disappeared |
Type Definitions
| Name | Syntax | Status | Description |
|---|---|---|---|
| Pm1001lhrAdjustValue | INTEGER { otxadjustvalue0(0), otxadjustvalue1(1), otxadjustvalue2(2), otxadjustvalue3(3), otxadjustvalue4(4), otxadjustvalue5(5), otxadjustvalue6(6), otxadjustvalue7(7), otxadjustvalue8(8), otxadjustvalue9(9), otxadjustvalue10(10), } | current | Different values in Adjust mode on OTX-TLH on line ports |
| Pm1001lhrOtxChannel | INTEGER { } | current | Channel selection on OTX-TLH on line ports |
| Pm1001lhrOtxGrid | INTEGER { otxgrid200(200), otxgrid100(100), otxgrid50(50), } | current | Different grids on OTX-TLH on line ports |
| Pm1001lhrOtxMode | INTEGER { otx80mode(1), otx60mode(2), otxadjustmode(4), } | current | Different modes on OTX-TLH on line ports |