MIB Viewer

EKINOPS-Pm1004V-MIB

611 objects
MIB for managing Ekinops modules with PM1004V software
OIDNameAccessStatusDescription
1.3.6.1.4.1.20044.32IdentitymodulePm1004vMIB for managing Ekinops modules with PM1004V software
1.3.6.1.4.1.20044.32.2Nodepm1004valarms
1.3.6.1.4.1.20044.32.2.1Nodepm1004vAlmOther
1.3.6.1.4.1.20044.32.2.1.1Nodepm1004vAlmOtherNurg
1.3.6.1.4.1.20044.32.2.1.1.2Nodepm1004vAlmsynthAlm2
1.3.6.1.4.1.20044.32.2.1.1.2.1Scalarpm1004vAlmConfTableSaveread-onlycurrentPM Configuration Save :This OID is at 1 during the saving of a new configuration table in the module Flash memory. <Condtype> CONF_TABLE_SAVE <Probcause> other…
1.3.6.1.4.1.20044.32.2.1.1.2.2Scalarpm1004vAlmInvUploadread-onlycurrentInventory Upload :This OID is at 1 during the uploading of PM inventory information. <Condtype> INV_UPLOAD <Probcause> other (1) <Alarmtype> other (1) <Polarit…
1.3.6.1.4.1.20044.32.2.1.1.2.3Scalarpm1004vAlmConfTableLoadread-onlycurrentPM Configuration Load :This OID is at 1 during the loading of configuration tables in the modules RAM. <Condtype> CONF_TABLE_LOAD <Probcause> other (1) <Alarmt…
1.3.6.1.4.1.20044.32.2.1.1.2.4Scalarpm1004vAlmCorrelatOffread-onlycurrentNot Used :This OID, when set, indicates that alarm correlation is not being performed. <Condtype> CORRELAT_OFF <Probcause> other (1) <Alarmtype> other (1) <Pol…
1.3.6.1.4.1.20044.32.2.1.1.2.5Scalarpm1004vAlmMaintenanceOnread-onlycurrentMaintenance Mode :This OID indicates that the PM is in maintenance mode. <Help> This alarm indicates that the maintenance mode is enabled on the PM <Condtype> …
1.3.6.1.4.1.20044.32.2.1.2Nodepm1004vAlmOtherUrg
1.3.6.1.4.1.20044.32.2.1.2.194Nodepm1004vAlmmodInitFailLevel2
1.3.6.1.4.1.20044.32.2.1.2.194.1Scalarpm1004vAlmLedFailread-onlycurrentLed Fail :This OID indicates that Led register has not been correctly initalized <Help> This alarm indicates if the module LEDs are correctly initialized <Cond…
1.3.6.1.4.1.20044.32.2.1.2.194.2Scalarpm1004vAlmNextColdBootForcedread-onlycurrentNext Cold Boot Forced :This OID indicates that the next Reset will be forced Cold <Help> This alarm indicates that the next reset of the module will be forced …
1.3.6.1.4.1.20044.32.2.1.2.194.3Scalarpm1004vAlmBootUndoneread-onlycurrentBoot Undone :This OID indicates that the boot has not been correctly achieved <Help> This alarm indicates if the module has correctly boot <Condtype> BOOT_UNDO…
1.3.6.1.4.1.20044.32.2.1.2.194.4Scalarpm1004vAlmResetHwInitFailread-onlycurrentReset HW Init Fail :This OID indicates that the HW intialization has caused unknown intial conditions <Help> This alarm indicates if the HW has been correctly …
1.3.6.1.4.1.20044.32.2.1.2.194.5Scalarpm1004vAlmSwInitFailread-onlycurrentSW Init Fail :This OID indicates that the SW intialization has caused unknown intial conditions <Help> This alarm indicates if the SW module is correctly initi…
1.3.6.1.4.1.20044.32.2.1.2.195Nodepm1004vAlmmodInitFailLevel3
1.3.6.1.4.1.20044.32.2.1.2.195.1Scalarpm1004vAlmGwIdentFailread-onlycurrentGW Ident Fail :This OID indicates that GW identification has not been read <Help> This alarm indicates if the GW has been correctly identified <Condtype> GW_ID…
1.3.6.1.4.1.20044.32.2.1.2.195.2Scalarpm1004vAlmObmTypeReadFailread-onlycurrentOBM Type Read Fail :This OID indicates that OBM type has not been recognized <Help> This alarm indicates if the OBM board has been correctly identified <Condty…
1.3.6.1.4.1.20044.32.2.1.2.195.3Scalarpm1004vAlmInitModuleFailread-onlycurrentInit Module Fail :This OID indicates that the Module has not been correctly initialized <Help> This alarm indicates if the SW module is correctly initialized <…
1.3.6.1.4.1.20044.32.2.1.2.195.5Scalarpm1004vAlmXfp1InitFailread-onlycurrentXFP1 Init Fail :This OID indicates that the XFP has not been correctly initialized <Help> This alarm indicates if the line transceiver 1 is correctly initializ…
1.3.6.1.4.1.20044.32.2.1.2.195.6Scalarpm1004vAlmXfp2InitFailread-onlycurrentXFP2 Init Fail :This OID indicates that the XFP has not been correctly initialized <Help> This alarm indicates if the line transceiver 2 is correctly initializ…
1.3.6.1.4.1.20044.32.2.1.2.195.7Scalarpm1004vAlmLine1InitFailread-onlycurrentLine1 Init Fail :This OID indicates that the Line registersvsubset has not been correctly initialized <Help> This alarm indicates if the line port 1 is correct…
1.3.6.1.4.1.20044.32.2.1.2.195.8Scalarpm1004vAlmLine2InitFailread-onlycurrentLine2 Init Fail :This OID indicates that the Line register subset has not been correctly initialized <Help> This alarm indicates if the line port 2 is correctl…
1.3.6.1.4.1.20044.32.2.1.2.195.9Scalarpm1004vAlmClient1InitFailread-onlycurrentClient1 Init Fail :This OID indicates that Client 1 registers subset has not been correctly initialized <Help> This alarm indicates if the client port 1 is cor…
1.3.6.1.4.1.20044.32.2.1.2.195.10Scalarpm1004vAlmClient2InitFailread-onlycurrentClient2 Init Fail :This OID indicates that Client 2 registers subset has not been correctly initialized <Help> This alarm indicates if the client port 2 is cor…
1.3.6.1.4.1.20044.32.2.1.2.195.11Scalarpm1004vAlmClient3InitFailread-onlycurrentClient3 Init Fail :This OID indicates that Client 3 registers subset has not been correctly initialized <Help> This alarm indicates if the client port 3 is cor…
1.3.6.1.4.1.20044.32.2.1.2.195.12Scalarpm1004vAlmClient4InitFailread-onlycurrentClient4 Init Fail :This OID indicates that Client 4 registers subset has not been correctly initialized <Help> This alarm indicates if the client port 4 is cor…
1.3.6.1.4.1.20044.32.2.1.2.195.13Scalarpm1004vAlmClient5InitFailread-onlycurrentClient5 Init Fail :This OID indicates that Client 5 registers subset has not been correctly initialized <Help> This alarm indicates if the client port 5 is cor…
1.3.6.1.4.1.20044.32.2.1.2.195.14Scalarpm1004vAlmClient6InitFailread-onlycurrentClient6 Init Fail :This OID indicates that Client 6 registers subset has not been correctly initialized <Help> This alarm indicates if the client port 6 is cor…
1.3.6.1.4.1.20044.32.2.1.2.198Nodepm1004vAlmclientRxProt
1.3.6.1.4.1.20044.32.2.1.2.198.1Scalarpm1004vAlmAdddropClient1Westread-onlycurrentClient West Rx Side Active :This OID indicates the Client is active on West receiving side <Condtype> ADDDROP_CLIENT1_WEST <Probcause> other (1) <Alarmtype> ot…
1.3.6.1.4.1.20044.32.2.1.2.198.2Scalarpm1004vAlmAdddropClient2Westread-onlycurrentClient West Rx Side Active :This OID indicates the Client is active on West receiving side <Condtype> ADDDROP_CLIENT2_WEST <Probcause> other (1) <Alarmtype> ot…
1.3.6.1.4.1.20044.32.2.1.2.198.3Scalarpm1004vAlmAdddropClient3Westread-onlycurrentClient West Rx Side Active :This OID indicates the Client is active on West receiving side <Condtype> ADDDROP_CLIENT3_WEST <Probcause> other (1) <Alarmtype> ot…
1.3.6.1.4.1.20044.32.2.1.2.198.4Scalarpm1004vAlmAdddropClient4Westread-onlycurrentClient West Rx Side Active :This OID indicates the Client is active on West receiving side <Condtype> ADDDROP_CLIENT4_WEST <Probcause> other (1) <Alarmtype> ot…
1.3.6.1.4.1.20044.32.2.1.2.198.5Scalarpm1004vAlmAdddropClient5Westread-onlycurrentClient West Rx Side Active :This OID indicates the Client is active on West receiving side <Condtype> ADDDROP_CLIENT5_WEST <Probcause> other (1) <Alarmtype> ot…
1.3.6.1.4.1.20044.32.2.1.2.198.6Scalarpm1004vAlmAdddropClient6Westread-onlycurrentClient West Rx Side Active :This OID indicates the Client is active on West receiving side <Condtype> ADDDROP_CLIENT6_WEST <Probcause> other (1) <Alarmtype> ot…
1.3.6.1.4.1.20044.32.2.1.2.198.9Scalarpm1004vAlmAdddropClient1Eastread-onlycurrentClient East Rx Side Active :This OID indicates the Client is active on East receiving side <Condtype> ADDDROP_CLIENT1_EAST <Probcause> other (1) <Alarmtype> ot…
1.3.6.1.4.1.20044.32.2.1.2.198.10Scalarpm1004vAlmAdddropClient2Eastread-onlycurrentClient East Rx Side Active :This OID indicates the Client is active on East receiving side <Condtype> ADDDROP_CLIENT2_EAST <Probcause> other (1) <Alarmtype> ot…
1.3.6.1.4.1.20044.32.2.1.2.198.11Scalarpm1004vAlmAdddropClient3Eastread-onlycurrentClient East Rx Side Active :This OID indicates the Client is active on East receiving side <Condtype> ADDDROP_CLIENT3_EAST <Probcause> other (1) <Alarmtype> ot…
1.3.6.1.4.1.20044.32.2.1.2.198.12Scalarpm1004vAlmAdddropClient4Eastread-onlycurrentClient East Rx Side Active :This OID indicates the Client is active on East receiving side <Condtype> ADDDROP_CLIENT4_EAST <Probcause> other (1) <Alarmtype> ot…
1.3.6.1.4.1.20044.32.2.1.2.198.13Scalarpm1004vAlmAdddropClient5Eastread-onlycurrentClient East Rx Side Active :This OID indicates the Client is active on East receiving side <Condtype> ADDDROP_CLIENT5_EAST <Probcause> other (1) <Alarmtype> ot…
1.3.6.1.4.1.20044.32.2.1.2.198.14Scalarpm1004vAlmAdddropClient6Eastread-onlycurrentClient East Rx Side Active :This OID indicates the Client is active on East receiving side <Condtype> ADDDROP_CLIENT6_EAST <Probcause> other (1) <Alarmtype> ot…
1.3.6.1.4.1.20044.32.2.1.3Nodepm1004vAlmOtherCrit
1.3.6.1.4.1.20044.32.2.1.3.0Nodepm1004vAlmsynthAlm0
1.3.6.1.4.1.20044.32.2.1.3.0.9Scalarpm1004vAlmModGlobFailread-onlycurrentModule Failure :This OID is set on detection of a failure originating from the PM <Condtype> MOD_GLOB_FAIL <Probcause> equipmentMalfunction (16) <Alarmtype> sy…
1.3.6.1.4.1.20044.32.2.1.3.0.15Scalarpm1004vAlmDefFuseAread-onlycurrentFuse A Fail :This OID indicates that the fuse of the power input A is in fail condition <Help> Status of the Fuse A <Condtype> DEF_FUSE_A <Probcause> powerProb…
1.3.6.1.4.1.20044.32.2.1.3.0.16Scalarpm1004vAlmDefFuseBread-onlycurrentFuse B Fail :This OID indicates that the fuse of the power input B is in fail condition <Help> Status of the Fuse B <Condtype> DEF_FUSE_B <Probcause> powerProb…
1.3.6.1.4.1.20044.32.2.2Nodepm1004vAlmClient
1.3.6.1.4.1.20044.32.2.2.1Nodepm1004vAlmClientNurg
1.3.6.1.4.1.20044.32.2.2.1.48Tablepm1004vAlmsfpWarnDdmTablenot-accessiblecurrentList of pm1004vAlmsfpWarnDdm Article
1.3.6.1.4.1.20044.32.2.2.1.48.1Rowpm1004vAlmsfpWarnDdmEntrynot-accessiblecurrentRow definition for the pm1004vAlmsfpWarnDdm table
1.3.6.1.4.1.20044.32.2.2.1.48.1.1Columnpm1004vAlmsfpWarnDdmIndexread-onlycurrentIndex definition for the pm1004vAlmsfpWarnDdm table
1.3.6.1.4.1.20044.32.2.2.1.48.1.2Columnpm1004vAlmTxPwLowWngPortnread-onlycurrentClient SFP Tx Power Low Warning :Warning indicating that the SFP output power of port is lower than the threshold value written in the SFP EEPROM <Condtype> TX…
1.3.6.1.4.1.20044.32.2.2.1.48.1.3Columnpm1004vAlmTxPwrHighWngPortnread-onlycurrentClient SFP Tx Power High Warning :Warning indicating that the SFP output power of port is higher than the threshold value written in the SFP EEPROM <Condtype> …
1.3.6.1.4.1.20044.32.2.2.1.48.1.4Columnpm1004vAlmTxBiasLowWngPortnread-onlycurrentClient SFP Bias Low Warning :Warning indicating that the SFP laser bias current of port is lower than the threshold value written in the SFP EEPROM <Condtype> …
1.3.6.1.4.1.20044.32.2.2.1.48.1.5Columnpm1004vAlmTxBiasHighWngPortnread-onlycurrentClient SFP Bias High Warning :Warning indicating that the SFP laser bias current of port is higher than the threshold value written in the SFP EEPROM <Condtype…
1.3.6.1.4.1.20044.32.2.2.1.48.1.6Columnpm1004vAlmVccLowWngPortnread-onlycurrentClient SFP Power Supply Low Warning :Warning indicating that the SFP power supply of port is lower than the threshold value written in the SFP EEPROM <Condtype…
1.3.6.1.4.1.20044.32.2.2.1.48.1.7Columnpm1004vAlmVccHighWngPortnread-onlycurrentClient SFP Power Supply High Warning :Warning indicating that the SFP power supply of port is higher than the threshold value written in the SFP EEPROM <Condty…
1.3.6.1.4.1.20044.32.2.2.1.48.1.8Columnpm1004vAlmTempLowWngPortnread-onlycurrentClient SFP Temp Low Warning :Warning indicating that the SFP temperature of port is lower than the threshold value written in the SFP EEPROM <Condtype> TEMP_LO…
1.3.6.1.4.1.20044.32.2.2.1.48.1.9Columnpm1004vAlmTempHighWngPortnread-onlycurrentClient SFP Temp High Warning :Warning indicating that the SFP temperature of port is higher than the threshold value written in the SFP EEPROM <Condtype> TEMP_…
1.3.6.1.4.1.20044.32.2.2.1.48.1.16Columnpm1004vAlmRxPwrLowWngPortnread-onlycurrentClient SFP Rx Power Low Warning :Warning indicating that the SFP input power of port is lower than the threshold value written in the SFP EEPROM <Condtype> RX_…
1.3.6.1.4.1.20044.32.2.2.1.48.1.17Columnpm1004vAlmRxPwrHighWngPortnread-onlycurrentClient SFP Rx Power High Warning :Warning indicating that the SFP input power of port is higher than the threshold value written in the SFP EEPROM <Condtype> R…
1.3.6.1.4.1.20044.32.2.2.1.56Tablepm1004vAlmsfpCritDdmTablenot-accessiblecurrentList of pm1004vAlmsfpCritDdm Article
1.3.6.1.4.1.20044.32.2.2.1.56.1Rowpm1004vAlmsfpCritDdmEntrynot-accessiblecurrentRow definition for the pm1004vAlmsfpCritDdm table
1.3.6.1.4.1.20044.32.2.2.1.56.1.1Columnpm1004vAlmsfpCritDdmIndexread-onlycurrentIndex definition for the pm1004vAlmsfpCritDdm table
1.3.6.1.4.1.20044.32.2.2.1.56.1.2Columnpm1004vAlmTxPwrLowCritPortnread-onlycurrentClient SFP Custom Tx Power Low :Custom Alarm indicating that the SFP output power of port is lower than the custom threshold defined in configuration <Help> Cu…
1.3.6.1.4.1.20044.32.2.2.1.56.1.3Columnpm1004vAlmTxPwrHighCritPortnread-onlycurrentClient SFP Custom Tx Power High :Custom Alarm indicating that the SFP output power of port is higher than the custom threshold defined in configuration <Help> …
1.3.6.1.4.1.20044.32.2.2.1.56.1.16Columnpm1004vAlmRxPwrLowCritPortnread-onlycurrentClient SFP Custom Rx Power Low :Custom Alarm indicating that the SFP input power of port is lower than the custom threshold defined in configuration <Help> Cus…
1.3.6.1.4.1.20044.32.2.2.1.56.1.17Columnpm1004vAlmRxPwrHighCritPortnread-onlycurrentClient SFP Custom Rx Power High :Custom Alarm indicating that the SFP input power of port is higher than the custom threshold defined in configuration <Help> C…
1.3.6.1.4.1.20044.32.2.2.2Nodepm1004vAlmClientUrg
1.3.6.1.4.1.20044.32.2.2.2.32Tablepm1004vAlmsfpAlmDdmTablenot-accessiblecurrentList of pm1004vAlmsfpAlmDdm Article
1.3.6.1.4.1.20044.32.2.2.2.32.1Rowpm1004vAlmsfpAlmDdmEntrynot-accessiblecurrentRow definition for the pm1004vAlmsfpAlmDdm table
1.3.6.1.4.1.20044.32.2.2.2.32.1.1Columnpm1004vAlmsfpAlmDdmIndexread-onlycurrentIndex definition for the pm1004vAlmsfpAlmDdm table
1.3.6.1.4.1.20044.32.2.2.2.32.1.2Columnpm1004vAlmTxPwrLowAlaPortnread-onlycurrentClient SFP Tx Power Low :Alarm indicating that the SFP output power of port is lower than the threshold value written in the SFP EEPROM <Condtype> TX_PWR_LOW_A…
1.3.6.1.4.1.20044.32.2.2.2.32.1.3Columnpm1004vAlmTxPwrHighAlaPortnread-onlycurrentClient SFP Tx Power High :Alarm indicating that the SFP output power of port is higher than the threshold value written in the SFP EEPROM <Condtype> TX_PWR_HIG…
1.3.6.1.4.1.20044.32.2.2.2.32.1.4Columnpm1004vAlmTxBiasLowAlaPortnread-onlycurrentClient SFP Bias Low :Alarm indicating that the SFP laser bias current of port is lower than the threshold value written in the SFP EEPROM <Condtype> TX_BIAS_LO…
1.3.6.1.4.1.20044.32.2.2.2.32.1.5Columnpm1004vAlmTxBiasHighAlaPortnread-onlycurrentClient SFP Bias High :Alarm indicating that the SFP laser bias current of port is higher than the threshold value written in the SFP EEPROM <Condtype> TX_BIAS_…
1.3.6.1.4.1.20044.32.2.2.2.32.1.6Columnpm1004vAlmVccLowAlaPortnread-onlycurrentClient SFP Power Supply Low :Alarm indicating that the SFP power supply of port is lower than the threshold value written in the SFP EEPROM <Condtype> VCC_LOW_…
1.3.6.1.4.1.20044.32.2.2.2.32.1.7Columnpm1004vAlmVccHighAlaPortnread-onlycurrentClient SFP Power Supply High :Alarm indicating that the SFP power supply of port is higher than the threshold value written in the SFP EEPROM <Condtype> VCC_HI…
1.3.6.1.4.1.20044.32.2.2.2.32.1.8Columnpm1004vAlmTempLowAlaPortnread-onlycurrentClient SFP Temp Low :Alarm indicating that the SFP temperature of port is lower than the threshold value written in the SFP EEPROM <Condtype> TEMP_LOW_ALA_1 <P…
1.3.6.1.4.1.20044.32.2.2.2.32.1.9Columnpm1004vAlmTempHighAlaPortnread-onlycurrentClient SFP Temp High :Alarm indicating that the SFP temperature of port is higher than the threshold value written in the SFP EEPROM <Condtype> TEMP_HIGH_ALA_1…
1.3.6.1.4.1.20044.32.2.2.2.32.1.16Columnpm1004vAlmRxPwrLowAlaPortnread-onlycurrentClient SFP Rx Power Low :Alarm indicating that the SFP input power of port is lower than the threshold value written in the SFP EEPROM <Condtype> RX_PWR_LOW_AL…
1.3.6.1.4.1.20044.32.2.2.2.32.1.17Columnpm1004vAlmRxPwrHighAlaPortnread-onlycurrentClient SFP Rx Power High :Alarm indicating that the SFP input power of port is higher than the threshold value written in the SFP EEPROM <Condtype> RX_PWR_HIGH…
1.3.6.1.4.1.20044.32.2.2.3Nodepm1004vAlmClientCrit
1.3.6.1.4.1.20044.32.2.2.3.8Tablepm1004vAlmsynthAlmPortTablenot-accessiblecurrentList of pm1004vAlmsynthAlmPort Article
1.3.6.1.4.1.20044.32.2.2.3.8.1Rowpm1004vAlmsynthAlmPortEntrynot-accessiblecurrentRow definition for the pm1004vAlmsynthAlmPort table
1.3.6.1.4.1.20044.32.2.2.3.8.1.1Columnpm1004vAlmsynthAlmPortIndexread-onlycurrentIndex definition for the pm1004vAlmsynthAlmPort table
1.3.6.1.4.1.20044.32.2.2.3.8.1.2Columnpm1004vAlmSfpAbsentPortnread-onlycurrentClient SFP Absent :This OID indicates that the SFP module is not present in the client port (only significant on Client6-GbE port). <Help> This alarm indicates…
1.3.6.1.4.1.20044.32.2.2.3.8.1.3Columnpm1004vAlmDdmAbsentPortnread-onlycurrentDDM Supported On Client SFP :This OID indicates that the Client SFP module supports the Digital Diagnostic Monitoring function (only significant on Client6-GbE…
1.3.6.1.4.1.20044.32.2.2.3.8.1.5Columnpm1004vAlmHwFailAccPortnread-onlycurrentClient HW Fail :This OID indicates a failure on client port, most probably caused by a HW issue. <Condtype> HW_FAIL_ACC_1 <Probcause> equipmentMalfunction (16)…
1.3.6.1.4.1.20044.32.2.2.3.8.1.6Columnpm1004vAlmDwLsdPortnread-onlycurrentClient Signal Shutdown :This OID indicates the Client SFP transmitter output is ON. <Help> This status indicates if the client transceiver is ON or OFF <Condty…
1.3.6.1.4.1.20044.32.2.2.3.8.1.7Columnpm1004vAlmClientLocalOosTxPortnread-onlycurrentTx Client Port In Service :This OID indicates that the local Tx Client port is In Service (1) or Out of Service (2) <Help> This status indicates if the local T…
1.3.6.1.4.1.20044.32.2.2.3.8.1.8Columnpm1004vAlmClientLocalOosRxPortnread-onlycurrentRx Client Port In Service :This OID indicates that the local Rx Client port is In Service (1) or Out of Service (2) <Help> This status indicates if the local R…
1.3.6.1.4.1.20044.32.2.2.3.8.1.9Columnpm1004vAlmDwCaisPortnread-onlycurrentClient AIS Inserted :This OID indicates a CAIS has been inserted on the output client port. <Help> This status indictaes if a Client Alarm Indication Signal is…
1.3.6.1.4.1.20044.32.2.2.3.8.1.10Columnpm1004vAlmSfpDdmWarningPortnread-onlycurrentWarning On Client SFP DDM :This OID indicates a warning is being received from the Client SFP DDM (only significant on Client6-GbE port) <Help> This alarm indi…
1.3.6.1.4.1.20044.32.2.2.3.8.1.11Columnpm1004vAlmSfpDdmAlmPortnread-onlycurrentAlarm On Client SFP DDM :This OID indicates an alarm is being received from the Client SFP DDM (only significant on Client6-GbE port) <Help> This alarm indicat…
1.3.6.1.4.1.20044.32.2.2.3.8.1.12Columnpm1004vAlmSfpDdmCritPortnread-onlycurrentCustom Alarm On Client SFP DDM :This OID indicates a Custom alarm is being received from the Client SFP DDM <Help> This alarm indicates if a DDM Custom Alarm h…
1.3.6.1.4.1.20044.32.2.2.3.8.1.13Columnpm1004vAlmFailAccPortnread-onlycurrentClient Access Fail :This OID indicates a failure on the Client port <Condtype> FAIL_ACC_1 <Probcause> equipmentMalfunction (16) <Alarmtype> synthesisAlarm (12)…
1.3.6.1.4.1.20044.32.2.2.3.8.1.16Columnpm1004vAlmClientActivePortnread-onlycurrentClient Sink (Line1 Or Line2) :This bit indicates the Client #n is active on receive side <Help> This status indicates whether the Client is extracted from Line…
1.3.6.1.4.1.20044.32.2.2.3.8.1.17Columnpm1004vAlmUpCsfPortnread-onlycurrentClient Signal Fail Inserted :This OID indicates a CSF has been inserted in the upstream client port. <Help> This status indicates if a Client Signal Fail is cu…
1.3.6.1.4.1.20044.32.2.2.3.16Tablepm1004vAlmaccessioAlmTablenot-accessiblecurrentList of pm1004vAlmaccessioAlm Article
1.3.6.1.4.1.20044.32.2.2.3.16.1Rowpm1004vAlmaccessioAlmEntrynot-accessiblecurrentRow definition for the pm1004vAlmaccessioAlm table
1.3.6.1.4.1.20044.32.2.2.3.16.1.1Columnpm1004vAlmaccessioAlmIndexread-onlycurrentIndex definition for the pm1004vAlmaccessioAlm table
1.3.6.1.4.1.20044.32.2.2.3.16.1.2Columnpm1004vAlmDwLasFailPortnread-onlycurrentClient SFP Tx Failed :This OID indicates that the transmitter fails for the SFP plugged into the client port. This alarm reports the transmitter failure alarm …
1.3.6.1.4.1.20044.32.2.2.3.16.1.5Columnpm1004vAlmUpLosPortnread-onlycurrentClient Input Loss Of Signal :This OID indicates that no signal is present on the client port <Help> This alarm indicates if a signal is detected on the client …
1.3.6.1.4.1.20044.32.2.2.3.72Tablepm1004vAlmmapperDeAlmTablenot-accessiblecurrentList of pm1004vAlmmapperDeAlm Article
1.3.6.1.4.1.20044.32.2.2.3.72.1Rowpm1004vAlmmapperDeAlmEntrynot-accessiblecurrentRow definition for the pm1004vAlmmapperDeAlm table
1.3.6.1.4.1.20044.32.2.2.3.72.1.1Columnpm1004vAlmmapperDeAlmIndexread-onlycurrentIndex definition for the pm1004vAlmmapperDeAlm table
1.3.6.1.4.1.20044.32.2.2.3.72.1.2Columnpm1004vAlmUpAccOosPortnread-onlycurrentClient Loss Of Synchro :This OID indicates the upstream client input port has lost synchronization on its decoder <Help> This alarms indicates if the input cli…
1.3.6.1.4.1.20044.32.2.2.3.72.1.11Columnpm1004vAlmUpBufferOvlPortnread-onlycurrentClient Upstream Buffer Overload :This OID indicates that the rate adaptation buffer for client port is in overload. <Help> This alarm indicates if there is a u…
1.3.6.1.4.1.20044.32.2.2.3.72.1.12Columnpm1004vAlmDwCsfDetPortnread-onlycurrentClient Signal Fail Detected :This OID indicates that a CSF has been detected on client port in the downstream direction <Help> This alarm indicates if a Client…
1.3.6.1.4.1.20044.32.2.2.3.72.1.15Columnpm1004vAlmDwBufferOvlPortnread-onlycurrentClient Downstream Buffer Overload :This OID indicates that the de-mapper buffer for client port is in overload. <Help> This alarm indicates if there is a downs…
1.3.6.1.4.1.20044.32.2.2.3.112Tablepm1004vAlmvideoProtocolStatusTablenot-accessiblecurrentList of pm1004vAlmvideoProtocolStatus Article
1.3.6.1.4.1.20044.32.2.2.3.112.1Rowpm1004vAlmvideoProtocolStatusEntrynot-accessiblecurrentRow definition for the pm1004vAlmvideoProtocolStatus table
1.3.6.1.4.1.20044.32.2.2.3.112.1.1Columnpm1004vAlmvideoProtocolStatusIndexread-onlycurrentIndex definition for the pm1004vAlmvideoProtocolStatus table
1.3.6.1.4.1.20044.32.2.2.3.112.1.2Columnpm1004vAlmSdiTxPortnread-onlycurrentSDI Detected On Tx :This OID indicates that the SDI protocol has been detected on the transmit side of the port (only significant on Video2 to Video 5 ports) <…
1.3.6.1.4.1.20044.32.2.2.3.112.1.3Columnpm1004vAlmHdSdiPalTxPortnread-onlycurrentHD-SDI-PAL Detected On Tx :This OID indicates that the HD-SDI-PAL protocol has been detected on the transmit side of the port (only significant on Video2 to Vi…
1.3.6.1.4.1.20044.32.2.2.3.112.1.4Columnpm1004vAlmHdSdiNtscTxPortnread-onlycurrentHD-SDI-NTSC Detected On Tx :This OID indicates that the HD-SDI-NTSC protocol has been detected on the transmit side of the port (only significant on Video2 to …
1.3.6.1.4.1.20044.32.2.2.3.112.1.5Columnpm1004vAlmDvbAsiTxPortnread-onlycurrentDVB-ASI Detected On Tx :This OID indicates that the DVB-ASI protocol has been detected on the transmit side of the port (only significant on Video2 to Video 5 …
1.3.6.1.4.1.20044.32.2.2.3.112.1.6Columnpm1004vAlmFastEtherTxPortnread-onlycurrentFast Ethernet Detected On Tx :This OID indicates that the Fast Ethernet protocol has been detected on the port (only significant on Client1-RJ45 port) <Help> T…
1.3.6.1.4.1.20044.32.2.2.3.112.1.7Columnpm1004vAlmGbeTxPortnread-onlycurrentGigabit Ethernet Detected On Tx :This OID indicates that the Gigabit Ethernet protocol has been detected on the port (only significant on Client6-GbE port) <He…
1.3.6.1.4.1.20044.32.2.2.3.112.1.10Columnpm1004vAlmSdiRxPortnread-onlycurrentSDI Detected On Rx :This OID indicates that the SDI protocol has been detected on the receive side of the port (only significant on Video2 to Video 5 ports) <H…
1.3.6.1.4.1.20044.32.2.2.3.112.1.11Columnpm1004vAlmHdSdiPalRxPortnread-onlycurrentHD-SDI-PAL Detected On Rx :This OID indicates that the HD-SDI-PAL protocol has been detected on the receive side of the port (only significant on Video2 to Vid…
1.3.6.1.4.1.20044.32.2.2.3.112.1.12Columnpm1004vAlmHdSdiNtscRxPortnread-onlycurrentHD-SDI-NTSC Detected On Rx :This OID indicates that the HD-SDI-NTSC protocol has been detected on the receive side of the port (only significant on Video2 to V…
1.3.6.1.4.1.20044.32.2.2.3.112.1.13Columnpm1004vAlmDvbAsiRxPortnread-onlycurrentDVB-ASI Detected On Rx :This OID indicates that the DVB-ASI protocol has been detected on the receive side of the port (only significant on Video2 to Video 5 p…
1.3.6.1.4.1.20044.32.2.2.3.112.1.14Columnpm1004vAlmFastEtherRxPortnread-onlycurrentFast Ethernet Detected On Rx :This OID indicates that the Fast Ethernet protocol has been detected on the port (only significant on Client1-RJ45 port) <Help> T…
1.3.6.1.4.1.20044.32.2.2.3.112.1.15Columnpm1004vAlmGbeRxPortnread-onlycurrentGigabit Ethernet Detected On Rx :This OID indicates that the Gigabit Ethernet protocol has been detected on the port (only significant on Client6-GbE port) <He…
1.3.6.1.4.1.20044.32.2.3Nodepm1004vAlmLine
1.3.6.1.4.1.20044.32.2.3.1Nodepm1004vAlmLineNurg
1.3.6.1.4.1.20044.32.2.3.1.209Tablepm1004vAlmlineXfp1WarningsTablenot-accessiblecurrentList of pm1004vAlmlineXfp1Warnings Article
1.3.6.1.4.1.20044.32.2.3.1.209.1Rowpm1004vAlmlineXfp1WarningsEntrynot-accessiblecurrentRow definition for the pm1004vAlmlineXfp1Warnings table
1.3.6.1.4.1.20044.32.2.3.1.209.1.1Columnpm1004vAlmlineXfp1WarningsIndexread-onlycurrentIndex definition for the pm1004vAlmlineXfp1Warnings table
1.3.6.1.4.1.20044.32.2.3.1.209.1.2Columnpm1004vAlmTxPowerLowWarningPortnread-onlycurrentLine Optical Tx Power Low Warning :Warning indicating that the XFP/OTX transmitter transmitter output power is lower than the threshold value written in the XF…
1.3.6.1.4.1.20044.32.2.3.1.209.1.3Columnpm1004vAlmTxPowerHighWarningPortnread-onlycurrentLine Optical Tx Power High Warning :Warning indicating that the XFP/OTX transmitter transmitter output power is higher than the threshold value written in the …
1.3.6.1.4.1.20044.32.2.3.1.209.1.4Columnpm1004vAlmTxBiasLowWarningPortnread-onlycurrentLine Transceiver Bias Low Warning :Warning indicating that the XFP/OTX transmitter laser bias current is lower than the threshold value written in the XFP/OTX …
1.3.6.1.4.1.20044.32.2.3.1.209.1.5Columnpm1004vAlmTxBiasHighWarningPortnread-onlycurrentLine Transceiver Bias High Warning :Warning indicating that the XFP/OTX transmitter laser bias current is higher than the threshold value written in the XFP EE…
1.3.6.1.4.1.20044.32.2.3.1.209.1.8Columnpm1004vAlmTempLowWarningPortnread-onlycurrentLine Transceiver Temp Low Warning :Warning indicating that the XFP/OTX temperature is lower than the threshold value written in the XFP/OTX EEPROM <Condtype> T…
1.3.6.1.4.1.20044.32.2.3.1.209.1.9Columnpm1004vAlmTempHighWarningPortnread-onlycurrentLine Transceiver Temp High Warning :Warning indicating that the XFP/OTX temperature is higher than the threshold value written in the XFP EEPROM <Condtype> TEM…
1.3.6.1.4.1.20044.32.2.3.1.209.1.16Columnpm1004vAlmRxPowerLowWarningPortnread-onlycurrentLine Optical Rx Power Low Warning :Warning indicating that the XFP received optical power is lower than the threshold value written in the XFP EEPROM <Condtype…
1.3.6.1.4.1.20044.32.2.3.1.209.1.17Columnpm1004vAlmRxPowerHighWarningPortnread-onlycurrentLine Optical Rx Power High Warning :Warning indicating that the XFP received optical power is higher than the threshold value written in the XFP EEPROM <Condty…
1.3.6.1.4.1.20044.32.2.3.1.225Tablepm1004vAlmlineOtx1TlhWarningsTablenot-accessiblecurrentList of pm1004vAlmlineOtx1TlhWarnings Article
1.3.6.1.4.1.20044.32.2.3.1.225.1Rowpm1004vAlmlineOtx1TlhWarningsEntrynot-accessiblecurrentRow definition for the pm1004vAlmlineOtx1TlhWarnings table
1.3.6.1.4.1.20044.32.2.3.1.225.1.1Columnpm1004vAlmlineOtx1TlhWarningsIndexread-onlycurrentIndex definition for the pm1004vAlmlineOtx1TlhWarnings table
1.3.6.1.4.1.20044.32.2.3.1.225.1.6Columnpm1004vAlmLineModulatorAgingHighWarningPortnread-onlycurrentLine Modulator Aging High Warning :Warning indicating the Line OTX TLH modulator aging is higher than the threshold written in the EEPROM <Condtype> LINE_MODUL…
1.3.6.1.4.1.20044.32.2.3.1.225.1.7Columnpm1004vAlmLineAgingHighWarningPortnread-onlycurrentLine OTX TLH Aging High Warning :Warning indicating the Line OTX TLH aging is higher than the threshold written in the EEPROM <Condtype> LINE_AGING_HIGH_WARNIN…
1.3.6.1.4.1.20044.32.2.3.1.225.1.13Columnpm1004vAlmLineFreqDevHighWarningPortnread-onlycurrentLine Freq. Deviation High Warning :Warning indicating the Line OTX TLH frequency deviation is higher than the threshold written in the EEPROM <Condtype> LINE_F…
1.3.6.1.4.1.20044.32.2.3.1.225.1.15Columnpm1004vAlmLineLaserTempHighWarningPortnread-onlycurrentLine Laser Temp. High Warning :Warning indicating the Line OTX TLH laser temperature is higher than the threshold written in the EEPROM <Condtype> LINE_LASER_T…
1.3.6.1.4.1.20044.32.2.3.2Nodepm1004vAlmLineUrg
1.3.6.1.4.1.20044.32.2.3.2.208Tablepm1004vAlmlineXfp1AlarmTablenot-accessiblecurrentList of pm1004vAlmlineXfp1Alarm Article
1.3.6.1.4.1.20044.32.2.3.2.208.1Rowpm1004vAlmlineXfp1AlarmEntrynot-accessiblecurrentRow definition for the pm1004vAlmlineXfp1Alarm table
1.3.6.1.4.1.20044.32.2.3.2.208.1.1Columnpm1004vAlmlineXfp1AlarmIndexread-onlycurrentIndex definition for the pm1004vAlmlineXfp1Alarm table
1.3.6.1.4.1.20044.32.2.3.2.208.1.2Columnpm1004vAlmTxPowerLowAlarmPortnread-onlycurrentLine Optical Tx Power Low :Alarm indicating that the XFP/OTX transmitter transmitter output power is lower than the threshold value written in the XFP/OTX EEPR…
1.3.6.1.4.1.20044.32.2.3.2.208.1.3Columnpm1004vAlmTxPowerHighAlarmPortnread-onlycurrentLine Optical Tx Power High :Alarm indicating that the XFP/OTX transmitter transmitter output power is higher than the threshold value written in the XFP EEPROM…
1.3.6.1.4.1.20044.32.2.3.2.208.1.4Columnpm1004vAlmTxBiasLowAlarmPortnread-onlycurrentLine Transceiver Bias Low :Alarm indicating that the XFP/OTX transmitter laser bias current is lower than the threshold value written in the XFP/OTX EEPROM <Co…
1.3.6.1.4.1.20044.32.2.3.2.208.1.5Columnpm1004vAlmTxBiasHighAlarmPortnread-onlycurrentLine Transceiver Bias High :Alarm indicating that the XFP/OTX transmitter laser bias current is higher than the threshold value written in the XFP EEPROM <Cond…
1.3.6.1.4.1.20044.32.2.3.2.208.1.8Columnpm1004vAlmTempLowAlarmPortnread-onlycurrentLine Transceiver Temp Low :Alarm indicating that the XFP/OTX temperature is lower than the threshold value written in the XFP/OTX EEPROM <Condtype> TEMP_LOW_AL…
1.3.6.1.4.1.20044.32.2.3.2.208.1.9Columnpm1004vAlmTempHighAlarmPortnread-onlycurrentLine Transceiver Temp High :Alarm indicating that the XFP/OTX temperature is higher than the threshold value written in the XFP EEPROM <Condtype> TEMP_HIGH_ALA…
1.3.6.1.4.1.20044.32.2.3.2.208.1.16Columnpm1004vAlmRxPowerLowAlarmPortnread-onlycurrentLine Optical Rx Power Low :Alarm indicating that the XFP received optical power is lower than the threshold value written in the XFP EEPROM <Condtype> RX_POWER…
1.3.6.1.4.1.20044.32.2.3.2.208.1.17Columnpm1004vAlmRxPowerHighAlarmPortnread-onlycurrentLine Optical Rx Power High :Alarm indicating that the XFP received optical power is higher than the threshold value written in the XFP EEPROM <Condtype> RX_POW…
1.3.6.1.4.1.20044.32.2.3.2.210Tablepm1004vAlmlineXfp1CritTablenot-accessiblecurrentList of pm1004vAlmlineXfp1Crit Article
1.3.6.1.4.1.20044.32.2.3.2.210.1Rowpm1004vAlmlineXfp1CritEntrynot-accessiblecurrentRow definition for the pm1004vAlmlineXfp1Crit table
1.3.6.1.4.1.20044.32.2.3.2.210.1.1Columnpm1004vAlmlineXfp1CritIndexread-onlycurrentIndex definition for the pm1004vAlmlineXfp1Crit table
1.3.6.1.4.1.20044.32.2.3.2.210.1.2Columnpm1004vAlmTxPowerLowCritPortnread-onlycurrentLine Custom Tx Power Low :Custom Alarm indicating that the XFP/OTX output power of port is lower than the custom threshold defined in configuration <Help> Cust…
1.3.6.1.4.1.20044.32.2.3.2.210.1.3Columnpm1004vAlmTxPowerHighCritPortnread-onlycurrentLine Custom Tx Power High :Custom Alarm indicating that the XFP/OTX output power of port is higher than the custom threshold defined in configuration <Help> Cu…
1.3.6.1.4.1.20044.32.2.3.2.210.1.16Columnpm1004vAlmRxPowerLowCritPortnread-onlycurrentLine Custom Rx Power Low :Custom Alarm indicating that the XFP/OTX input power of port is lower than the custom threshold defined in configuration <Help> Custo…
1.3.6.1.4.1.20044.32.2.3.2.210.1.17Columnpm1004vAlmRxPowerHighCritPortnread-onlycurrentLine Custom Rx Power High :Custom Alarm indicating that the XFP/OTX input power of port is higher than the custom threshold defined in configuration <Help> Cus…
1.3.6.1.4.1.20044.32.2.3.2.212Tablepm1004vAlmlineXfp1SupplyAlarmTablenot-accessiblecurrentList of pm1004vAlmlineXfp1SupplyAlarm Article
1.3.6.1.4.1.20044.32.2.3.2.212.1Rowpm1004vAlmlineXfp1SupplyAlarmEntrynot-accessiblecurrentRow definition for the pm1004vAlmlineXfp1SupplyAlarm table
1.3.6.1.4.1.20044.32.2.3.2.212.1.1Columnpm1004vAlmlineXfp1SupplyAlarmIndexread-onlycurrentIndex definition for the pm1004vAlmlineXfp1SupplyAlarm table
1.3.6.1.4.1.20044.32.2.3.2.212.1.2Columnpm1004vAlmVee5LowAlarmPortnread-onlycurrentVEE5 Power Supply Low :Alarm indicating the XFP/OTX VEE5 power supply is lower than the threshold written in the EEPROM <Condtype> VEE5_LOW_ALARM_1 <Probcause>…
1.3.6.1.4.1.20044.32.2.3.2.212.1.3Columnpm1004vAlmVee5HighAlarmPortnread-onlycurrentVEE5 Power Supply High :Alarm indicating the XFP/OTX VEE5 power supply is higher than the threshold written in the EEPROM <Condtype> VEE5_HIGH_ALARM_1 <Probcau…
1.3.6.1.4.1.20044.32.2.3.2.212.1.4Columnpm1004vAlmVcc2LowAlarmPortnread-onlycurrentVCC2 Power Supply Low :Alarm indicating the XFP/OTX VCC2 power supply is lower than the threshold written in the EEPROM <Condtype> VCC2_LOW_ALARM_1 <Probcause>…
1.3.6.1.4.1.20044.32.2.3.2.212.1.5Columnpm1004vAlmVcc2HighAlarmPortnread-onlycurrentVCC2 Power Supply High :Alarm indicating the XFP/OTX VCC2 power supply is higher than the threshold written in the EEPROM <Condtype> VCC2_HIGH_ALARM_1 <Probcau…
1.3.6.1.4.1.20044.32.2.3.2.212.1.6Columnpm1004vAlmVcc3LowAlarmPortnread-onlycurrentVCC3 Power Supply Low :Alarm indicating the XFP/OTX VCC3 power supply is lower than the threshold written in the EEPROM <Condtype> VCC3_LOW_ALARM_1 <Probcause>…
1.3.6.1.4.1.20044.32.2.3.2.212.1.7Columnpm1004vAlmVcc3HighAlarmPortnread-onlycurrentVCC3 Power Supply High :Alarm indicating the XFP/OTX VCC3 power supply is higher than the threshold written in the EEPROM <Condtype> VCC3_HIGH_ALARM_1 <Probcau…
1.3.6.1.4.1.20044.32.2.3.2.212.1.8Columnpm1004vAlmVcc5LowAlarmPortnread-onlycurrentVCC5 Power Supply Low :Alarm indicating the XFP/OTX VCC5 power supply is lower than the threshold written in the EEPROM <Condtype> VCC5_LOW_ALARM_1 <Probcause>…
1.3.6.1.4.1.20044.32.2.3.2.212.1.9Columnpm1004vAlmVcc5HighAlarmPortnread-onlycurrentVCC5 Power Supply High :Alarm indicating the XFP/OTX VCC5 power supply is higher than the threshold written in the EEPROM <Condtype> VCC5_HIGH_ALARM_1 <Probcau…
1.3.6.1.4.1.20044.32.2.3.2.212.1.10Columnpm1004vAlmVee5LowWarningPortnread-onlycurrentVEE5 Power Supply Low Warning :Warning indicating the XFP/OTX VEE5 power supply is lower than the threshold written in the EEPROM <Condtype> VEE5_LOW_WARNING_1…
1.3.6.1.4.1.20044.32.2.3.2.212.1.11Columnpm1004vAlmVee5HighWarningPortnread-onlycurrentVEE5 Power Supply High Warning :Warning indicating the XFP/OTX VEE5 power supply is higher than the threshold written in the EEPROM <Condtype> VEE5_HIGH_WARNIN…
1.3.6.1.4.1.20044.32.2.3.2.212.1.12Columnpm1004vAlmVcc2LowWarningPortnread-onlycurrentVCC2 Power Supply Low Warning :Warning indicating the XFP/OTX VCC2 power supply is lower than the threshold written in the EEPROM <Condtype> VCC2_LOW_WARNING_1…
1.3.6.1.4.1.20044.32.2.3.2.212.1.13Columnpm1004vAlmVcc2HighWarningPortnread-onlycurrentVCC2 Power Supply High Warning :Warning indicating the XFP/OTX VCC2 power supply is higher than the threshold written in the EEPROM <Condtype> VCC2_HIGH_WARNIN…
1.3.6.1.4.1.20044.32.2.3.2.212.1.14Columnpm1004vAlmVcc3LowWarningPortnread-onlycurrentVCC3 Power Supply Low Warning :Warning indicating the XFP/OTX VCC3 power supply is lower than the threshold written in the EEPROM <Condtype> VCC3_LOW_WARNING_1…
1.3.6.1.4.1.20044.32.2.3.2.212.1.15Columnpm1004vAlmVcc3HighWarningPortnread-onlycurrentVCC3 Power Supply High Warning :Warning indicating the XFP/OTX VCC3 power supply is higher than the threshold written in the EEPROM <Condtype> VCC3_HIGH_WARNIN…
1.3.6.1.4.1.20044.32.2.3.2.212.1.16Columnpm1004vAlmVcc5LowWarningPortnread-onlycurrentVCC5 Power Supply Low Warning :Warning indicating the XFP/OTX VCC5 power supply is lower than the threshold written in the EEPROM <Condtype> VCC5_LOW_WARNING_1…
1.3.6.1.4.1.20044.32.2.3.2.212.1.17Columnpm1004vAlmVcc5HighWarningPortnread-onlycurrentVCC5 Power Supply High Warning :Warning indicating the XFP/OTX VCC5 power supply is higher than the threshold written in the EEPROM <Condtype> VCC5_HIGH_WARNIN…
1.3.6.1.4.1.20044.32.2.3.2.224Tablepm1004vAlmlineOtx1TlhAlarmsTablenot-accessiblecurrentList of pm1004vAlmlineOtx1TlhAlarms Article
1.3.6.1.4.1.20044.32.2.3.2.224.1Rowpm1004vAlmlineOtx1TlhAlarmsEntrynot-accessiblecurrentRow definition for the pm1004vAlmlineOtx1TlhAlarms table
1.3.6.1.4.1.20044.32.2.3.2.224.1.1Columnpm1004vAlmlineOtx1TlhAlarmsIndexread-onlycurrentIndex definition for the pm1004vAlmlineOtx1TlhAlarms table
1.3.6.1.4.1.20044.32.2.3.2.224.1.6Columnpm1004vAlmLineModulatorAgingHighAlaPortnread-onlycurrentLine Modulator Aging High Alarm :Alarm indicating the Line OTX TLH modulator aging is higher than the threshold written in the EEPROM <Condtype> LINE_MODULATOR…
1.3.6.1.4.1.20044.32.2.3.2.224.1.7Columnpm1004vAlmLineAgingHighAlaPortnread-onlycurrentLine OTX TLH Aging High Alarm :Alarm indicating the Line OTX TLH aging is higher than the threshold written in the EEPROM <Condtype> LINE_AGING_HIGH_ALA_1 <Pro…
1.3.6.1.4.1.20044.32.2.3.2.224.1.13Columnpm1004vAlmLineFreqDevHighAlaPortnread-onlycurrentLine Freq. Deviation High Alarm :Alarm indicating the Line OTX TLH frequency deviation is higher than the threshold written in the EEPROM <Condtype> LINE_FREQ_…
1.3.6.1.4.1.20044.32.2.3.2.224.1.15Columnpm1004vAlmLineLaserTempHighAlaPortnread-onlycurrentLine Laser Temp. High Alarm :Alarm indicating the Line OTX TLH laser temperature is higher than the threshold written in the EEPROM <Condtype> LINE_LASER_TEMP_…
1.3.6.1.4.1.20044.32.2.3.3Nodepm1004vAlmLineCrit
1.3.6.1.4.1.20044.32.2.3.3.7Tablepm1004vAlmsynthAlmLineTablenot-accessiblecurrentList of pm1004vAlmsynthAlmLine Article
1.3.6.1.4.1.20044.32.2.3.3.7.1Rowpm1004vAlmsynthAlmLineEntrynot-accessiblecurrentRow definition for the pm1004vAlmsynthAlmLine table
1.3.6.1.4.1.20044.32.2.3.3.7.1.1Columnpm1004vAlmsynthAlmLineIndexread-onlycurrentIndex definition for the pm1004vAlmsynthAlmLine table
1.3.6.1.4.1.20044.32.2.3.3.7.1.2Columnpm1004vAlmXfpAbsentPortnread-onlycurrentLine Optical Module Absent :This OID indicates that the line optical interface (XFP or OTX) is not plugged in. <Help> This alarm indicates if the line transcei…
1.3.6.1.4.1.20044.32.2.3.3.7.1.3Columnpm1004vAlmXfpInitNotComplPortnread-onlycurrentLine Optical Module Ready :This OID indicates that the optical interface (XFP or OTX) is not operational. <Help> This status indicates if the line transceiver …
1.3.6.1.4.1.20044.32.2.3.3.7.1.5Columnpm1004vAlmLineHwFailPortnread-onlycurrentLine Port HW Failure :This OID indicates a failure on line port, most probably caused by a HW issue <Condtype> LINE_HW_FAIL <Probcause> equipmentMalfunction (1…
1.3.6.1.4.1.20044.32.2.3.3.7.1.6Columnpm1004vAlmXfpTxOffPortnread-onlycurrentLine Optical Module Laser Shutdown :This OID indicates the line optical output power is on <Help> This status indicates if the line transceiver laser is ON or …
1.3.6.1.4.1.20044.32.2.3.3.7.1.7Columnpm1004vAlmLineLocalOosPortnread-onlycurrentLine Port In Service :This OID indicates that the Line port is In Service (1) of Out or Service (2) <Help> This status indicates if the line port is in service…
1.3.6.1.4.1.20044.32.2.3.3.7.1.10Columnpm1004vAlmLineDdmWarningPortnread-onlycurrentWarning On Line Optical Module DDM :This OID indicates a warning is present coming out of Line optical interface DDM <Help> This alarm indicates if a DDM Warni…
1.3.6.1.4.1.20044.32.2.3.3.7.1.11Columnpm1004vAlmLineDdmAlmPortnread-onlycurrentAlarm On Line Optical Module DDM :This OID indicates an alarm is present coming out of Line optical interface DDM <Help> This alarm indicates if a DDM Alarm ha…
1.3.6.1.4.1.20044.32.2.3.3.7.1.12Columnpm1004vAlmLineDdmCritPortnread-onlycurrentCustom Alarm On Line XFP/OTX DDM :This OID indicates a Custom alarm is present coming out of Line optical interface DDM <Help> This alarm indicates if a DDM Cu…
1.3.6.1.4.1.20044.32.2.3.3.7.1.13Columnpm1004vAlmLineFailPortnread-onlycurrentLine Port Failure :This OID indicates a failure on the line port <Condtype> LINE_FAIL <Probcause> equipmentMalfunction (16) <Alarmtype> synthesisAlarm (12) <Po…
1.3.6.1.4.1.20044.32.2.3.3.7.1.17Columnpm1004vAlmLineActivePortnread-onlycurrentLine Active :This bit indicates the line #n is active on receive side <Help> This status indicates whether the line is active or standby. <Condtype> LINE_ACTIV…
1.3.6.1.4.1.20044.32.2.3.3.128Tablepm1004vAlmdfrmAlmTablenot-accessiblecurrentList of pm1004vAlmdfrmAlm Article
1.3.6.1.4.1.20044.32.2.3.3.128.1Rowpm1004vAlmdfrmAlmEntrynot-accessiblecurrentRow definition for the pm1004vAlmdfrmAlm table
1.3.6.1.4.1.20044.32.2.3.3.128.1.1Columnpm1004vAlmdfrmAlmIndexread-onlycurrentIndex definition for the pm1004vAlmdfrmAlm table
1.3.6.1.4.1.20044.32.2.3.3.128.1.5Columnpm1004vAlmDwLossofsyncPortnread-onlycurrentLoss Of Synchronisation :This OID indicates the upstream line input port is in Loss of Synchronization. <Help> This alarms indicates if the input signal is cor…
1.3.6.1.4.1.20044.32.2.3.3.133Tablepm1004vAlmlineSyncAlarmsTablenot-accessiblecurrentList of pm1004vAlmlineSyncAlarms Article
1.3.6.1.4.1.20044.32.2.3.3.133.1Rowpm1004vAlmlineSyncAlarmsEntrynot-accessiblecurrentRow definition for the pm1004vAlmlineSyncAlarms table
1.3.6.1.4.1.20044.32.2.3.3.133.1.1Columnpm1004vAlmlineSyncAlarmsIndexread-onlycurrentIndex definition for the pm1004vAlmlineSyncAlarms table
1.3.6.1.4.1.20044.32.2.3.3.133.1.13Columnpm1004vAlmDwLockerrPortnread-onlycurrentDownstream Clock Lock Error :This OID indicates that the deserializer input 10 Gb/s clock recovery is not locked. <Condtype> DW_LOCKERR <Probcause> receiveFail…
1.3.6.1.4.1.20044.32.2.3.3.133.1.14Columnpm1004vAlmUpLockerrPortnread-onlycurrentUpstream Clock Lock Error :This OID indicates that the serializer output 10 Gb/s clock multiplier unit is not locked. <Condtype> UP_LOCKERR <Probcause> receive…
1.3.6.1.4.1.20044.32.2.3.3.133.1.17Columnpm1004vAlmDwLosPortnread-onlycurrentLine Input Loss Of Signal :This OID indicates a loss of signal on the 10 Gb/s input. <Help> This alarm indicates if an optical signal is detected on the line t…
1.3.6.1.4.1.20044.32.2.3.3.211Tablepm1004vAlmlineXfp1AlarmsTablenot-accessiblecurrentList of pm1004vAlmlineXfp1Alarms Article
1.3.6.1.4.1.20044.32.2.3.3.211.1Rowpm1004vAlmlineXfp1AlarmsEntrynot-accessiblecurrentRow definition for the pm1004vAlmlineXfp1Alarms table
1.3.6.1.4.1.20044.32.2.3.3.211.1.1Columnpm1004vAlmlineXfp1AlarmsIndexread-onlycurrentIndex definition for the pm1004vAlmlineXfp1Alarms table
1.3.6.1.4.1.20044.32.2.3.3.211.1.3Columnpm1004vAlmModNrPortnread-onlycurrentLine Optical Module Not Ready :This OID indicates that the module is unable to determine correct data. <Help> This alarm indicates if the line transceiver is r…
1.3.6.1.4.1.20044.32.2.3.3.211.1.4Columnpm1004vAlmRxCdrNotLockedPortnread-onlycurrentLine Optical Rx CDR Unlocked :This OID indicates that a loss of lock on the receiving side CDR has been detected <Help> This alarm indicates if the Rx CDR is l…
1.3.6.1.4.1.20044.32.2.3.3.211.1.6Columnpm1004vAlmRxNrPortnread-onlycurrentLine Optical Rx Not Ready :This OID indicates that a condition has arisen leading to invalid data on the receiving side. <Help> This alarm indicates if the Rx …
1.3.6.1.4.1.20044.32.2.3.3.211.1.7Columnpm1004vAlmTxCdrNotLockedPortnread-onlycurrentLine Optical Tx CDR Unlocked :This OID indicates a loss of lock on the transmitting side CDR has been detected. <Help> This alarm indicates if the Tx CDR is lo…
1.3.6.1.4.1.20044.32.2.3.3.211.1.8Columnpm1004vAlmTxFaultPortnread-onlycurrentLine Optical Tx Failure :This OID indicates a fault condition on the laser detected by the safety syste <Help> This alarm indicates if the laser of the line tr…
1.3.6.1.4.1.20044.32.2.3.3.211.1.9Columnpm1004vAlmTxNrPortnread-onlycurrentLine Optical Tx Not Ready :This OID indicates a condition has arisen leading to invalid data on the transmitting side <Help> This alarm indicates if the Tx par…
1.3.6.1.4.1.20044.32.2.3.3.211.1.15Columnpm1004vAlmWavelengthUnlockedPortnread-onlycurrentLine Optical Tx Wavelength Unlocked :This OID indicates that the wavelength error is exceeding the manufacturer tolerance <Help> This alarm indicates if the wa…
1.3.6.1.4.1.20044.32.2.3.3.211.1.16Columnpm1004vAlmTecFaultPortnread-onlycurrentLine Optical Tx Temp Regul Failed :This OID indicates a failure on the TEC module <Help> This alarm indicates if the TEC of the line transceiver is in fail con…
1.3.6.1.4.1.20044.32.2.3.3.211.1.17Columnpm1004vAlmApdSupplyFaultPortnread-onlycurrentLine Rx Photodiode Power Failed :This OID indicates a failure on the APD power supply <Help> This alarm indicates if the APD power supply is in fail condition …
1.3.6.1.4.1.20044.32.3Nodepm1004vmeasures
1.3.6.1.4.1.20044.32.3.1Nodepm1004vMesrOther
1.3.6.1.4.1.20044.32.3.1.0Scalarpm1004vMesrsynth0read-onlydeprecatedNot Used :This OID gives the unit used on AUX1 measurement of XFP#1 (Unit = )
1.3.6.1.4.1.20044.32.3.1.1Scalarpm1004vMesrsynth1read-onlydeprecatedNot Used :This OID gives the unit used on AUX2 measurement of XFP#1 (Unit = )
1.3.6.1.4.1.20044.32.3.2Nodepm1004vMesrClient
1.3.6.1.4.1.20044.32.3.2.16Tablepm1004vMesrtempMeasTablenot-accessiblecurrentList of pm1004vMesrtempMeas Article
1.3.6.1.4.1.20044.32.3.2.16.1Rowpm1004vMesrtempMeasEntrynot-accessiblecurrentRow definition for the pm1004vMesrtempMeas table
1.3.6.1.4.1.20044.32.3.2.16.1.1Columnpm1004vMesrtempMeasIndexread-onlycurrentIndex definition for the pm1004vMesrtempMeas table
1.3.6.1.4.1.20044.32.3.2.16.1.2Columnpm1004vMesrtempMeasPortnread-onlycurrentClient SFP Temperature :This OID gives the temperature value of the SFP plugged in port, read from the DDM (Digital Diagnostic Monitoring) (Temperature = AV/25…
1.3.6.1.4.1.20044.32.3.2.24Tablepm1004vMesrvoltMeasTablenot-accessiblecurrentList of pm1004vMesrvoltMeas Article
1.3.6.1.4.1.20044.32.3.2.24.1Rowpm1004vMesrvoltMeasEntrynot-accessiblecurrentRow definition for the pm1004vMesrvoltMeas table
1.3.6.1.4.1.20044.32.3.2.24.1.1Columnpm1004vMesrvoltMeasIndexread-onlycurrentIndex definition for the pm1004vMesrvoltMeas table
1.3.6.1.4.1.20044.32.3.2.24.1.2Columnpm1004vMesrvoltMeasPortnread-onlycurrentClient SFP Power Supply :This OID gives the 3V3 voltage value of the SFP plugged into port, read from the DDM (Digital Diagnostic Monitoring) (Voltage = AV/100…
1.3.6.1.4.1.20044.32.3.2.32Tablepm1004vMesrbiasMeasTablenot-accessiblecurrentList of pm1004vMesrbiasMeas Article
1.3.6.1.4.1.20044.32.3.2.32.1Rowpm1004vMesrbiasMeasEntrynot-accessiblecurrentRow definition for the pm1004vMesrbiasMeas table
1.3.6.1.4.1.20044.32.3.2.32.1.1Columnpm1004vMesrbiasMeasIndexread-onlycurrentIndex definition for the pm1004vMesrbiasMeas table
1.3.6.1.4.1.20044.32.3.2.32.1.2Columnpm1004vMesrbiasMeasPortnread-onlycurrentClient SFP Laser Bias :This OID gives the bias value of the SFP plugged into port, read from the DDM (Digital Diagnostic Monitoring) (Bias = AV/500) (Unit = mA…
1.3.6.1.4.1.20044.32.3.2.40Tablepm1004vMesrtxpwrMeasTablenot-accessiblecurrentList of pm1004vMesrtxpwrMeas Article
1.3.6.1.4.1.20044.32.3.2.40.1Rowpm1004vMesrtxpwrMeasEntrynot-accessiblecurrentRow definition for the pm1004vMesrtxpwrMeas table
1.3.6.1.4.1.20044.32.3.2.40.1.1Columnpm1004vMesrtxpwrMeasIndexread-onlycurrentIndex definition for the pm1004vMesrtxpwrMeas table
1.3.6.1.4.1.20044.32.3.2.40.1.2Columnpm1004vMesrtxpwrMeasPortnread-onlycurrentClient SFP Tx Power :This OID gives the transmit power value of the SFP plugged into port, read from the DDM (Digital Diagnostic Monitoring) (Power = 10*log(AV…
1.3.6.1.4.1.20044.32.3.2.48Tablepm1004vMesrrxpwrMeasTablenot-accessiblecurrentList of pm1004vMesrrxpwrMeas Article
1.3.6.1.4.1.20044.32.3.2.48.1Rowpm1004vMesrrxpwrMeasEntrynot-accessiblecurrentRow definition for the pm1004vMesrrxpwrMeas table
1.3.6.1.4.1.20044.32.3.2.48.1.1Columnpm1004vMesrrxpwrMeasIndexread-onlycurrentIndex definition for the pm1004vMesrrxpwrMeas table
1.3.6.1.4.1.20044.32.3.2.48.1.2Columnpm1004vMesrrxpwrMeasPortnread-onlycurrentClient SFP Rx Power :This OID gives the receive power value of the SFP plugged into port, read in the DDM (Digital Diagnostic Monitoring) (Power = 10*log(AV)-4…
1.3.6.1.4.1.20044.32.3.3Nodepm1004vMesrLine
1.3.6.1.4.1.20044.32.3.3.208Tablepm1004vMesrxfp1LxModTempMeasTablenot-accessiblecurrentList of pm1004vMesrxfp1LxModTempMeas Article
1.3.6.1.4.1.20044.32.3.3.208.1Rowpm1004vMesrxfp1LxModTempMeasEntrynot-accessiblecurrentRow definition for the pm1004vMesrxfp1LxModTempMeas table
1.3.6.1.4.1.20044.32.3.3.208.1.1Columnpm1004vMesrxfp1LxModTempMeasIndexread-onlycurrentIndex definition for the pm1004vMesrxfp1LxModTempMeas table
1.3.6.1.4.1.20044.32.3.3.208.1.2Columnpm1004vMesrxfp1LxModTempMeasPortnread-onlycurrentLine Optical Module Temperature :This OID gives the temperature of the XFP or OTX plugged in line#n, read from the DDM (Digital Diagnostic Monitoring) (Tempera…
1.3.6.1.4.1.20044.32.3.3.209Tablepm1004vMesrxfp1ReservedTablenot-accessibledeprecatedList of pm1004vMesrxfp1Reserved Article
1.3.6.1.4.1.20044.32.3.3.209.1Rowpm1004vMesrxfp1ReservedEntrynot-accessibledeprecatedRow definition for the pm1004vMesrxfp1Reserved table
1.3.6.1.4.1.20044.32.3.3.209.1.1Columnpm1004vMesrxfp1ReservedIndexread-onlydeprecatedIndex definition for the pm1004vMesrxfp1Reserved table
1.3.6.1.4.1.20044.32.3.3.209.1.2Columnpm1004vMesrxfp1ReservedPortnread-onlydeprecatedNot Used :Reserved
1.3.6.1.4.1.20044.32.3.3.210Tablepm1004vMesrxfp1LoBiasCurrentMeasTablenot-accessiblecurrentList of pm1004vMesrxfp1LoBiasCurrentMeas Article
1.3.6.1.4.1.20044.32.3.3.210.1Rowpm1004vMesrxfp1LoBiasCurrentMeasEntrynot-accessiblecurrentRow definition for the pm1004vMesrxfp1LoBiasCurrentMeas table
1.3.6.1.4.1.20044.32.3.3.210.1.1Columnpm1004vMesrxfp1LoBiasCurrentMeasIndexread-onlycurrentIndex definition for the pm1004vMesrxfp1LoBiasCurrentMeas table
1.3.6.1.4.1.20044.32.3.3.210.1.2Columnpm1004vMesrxfp1LoBiasCurrentMeasPortnread-onlycurrentLine Optical Module Laser Bias :This OID gives the bias value of the XFP or OTX plugged in line #n, read from the DDM (Digital Diagnostic Monitoring) (Bias = A…
1.3.6.1.4.1.20044.32.3.3.211Tablepm1004vMesrxfp1LoTxPowerMeasTablenot-accessiblecurrentList of pm1004vMesrxfp1LoTxPowerMeas Article
1.3.6.1.4.1.20044.32.3.3.211.1Rowpm1004vMesrxfp1LoTxPowerMeasEntrynot-accessiblecurrentRow definition for the pm1004vMesrxfp1LoTxPowerMeas table
1.3.6.1.4.1.20044.32.3.3.211.1.1Columnpm1004vMesrxfp1LoTxPowerMeasIndexread-onlycurrentIndex definition for the pm1004vMesrxfp1LoTxPowerMeas table
1.3.6.1.4.1.20044.32.3.3.211.1.2Columnpm1004vMesrxfp1LoTxPowerMeasPortnread-onlycurrentLine Optical Module Tx Power :This OID gives the transmit power value of the XFP or OTX plugged in line #n, read from the DDM (Digital Diagnostic Monitoring) (…
1.3.6.1.4.1.20044.32.3.3.212Tablepm1004vMesrxfp1LiRxPowerMeasTablenot-accessiblecurrentList of pm1004vMesrxfp1LiRxPowerMeas Article
1.3.6.1.4.1.20044.32.3.3.212.1Rowpm1004vMesrxfp1LiRxPowerMeasEntrynot-accessiblecurrentRow definition for the pm1004vMesrxfp1LiRxPowerMeas table
1.3.6.1.4.1.20044.32.3.3.212.1.1Columnpm1004vMesrxfp1LiRxPowerMeasIndexread-onlycurrentIndex definition for the pm1004vMesrxfp1LiRxPowerMeas table
1.3.6.1.4.1.20044.32.3.3.212.1.2Columnpm1004vMesrxfp1LiRxPowerMeasPortnread-onlycurrentLine Optical Module Rx Power :This OID gives the receive power value of the XFP or OTX plugged in line #n, read from the DDM (Digital Diagnostic Monitoring) (P…
1.3.6.1.4.1.20044.32.3.3.213Tablepm1004vMesrxfp1LxAux1MeasTablenot-accessibledeprecatedList of pm1004vMesrxfp1LxAux1Meas Article
1.3.6.1.4.1.20044.32.3.3.213.1Rowpm1004vMesrxfp1LxAux1MeasEntrynot-accessibledeprecatedRow definition for the pm1004vMesrxfp1LxAux1Meas table
1.3.6.1.4.1.20044.32.3.3.213.1.1Columnpm1004vMesrxfp1LxAux1MeasIndexread-onlydeprecatedIndex definition for the pm1004vMesrxfp1LxAux1Meas table
1.3.6.1.4.1.20044.32.3.3.213.1.2Columnpm1004vMesrxfp1LxAux1MeasPortnread-onlydeprecatedNot Used :This OID gives the receive power value read in the DDM (Digital Diagnostic Monitoring) of the XFP or OTX plugged in line #n (Unit = ?)
1.3.6.1.4.1.20044.32.3.3.214Tablepm1004vMesrxfp1LxAux2MeasTablenot-accessibledeprecatedList of pm1004vMesrxfp1LxAux2Meas Article
1.3.6.1.4.1.20044.32.3.3.214.1Rowpm1004vMesrxfp1LxAux2MeasEntrynot-accessibledeprecatedRow definition for the pm1004vMesrxfp1LxAux2Meas table
1.3.6.1.4.1.20044.32.3.3.214.1.1Columnpm1004vMesrxfp1LxAux2MeasIndexread-onlydeprecatedIndex definition for the pm1004vMesrxfp1LxAux2Meas table
1.3.6.1.4.1.20044.32.3.3.214.1.2Columnpm1004vMesrxfp1LxAux2MeasPortnread-onlydeprecatedNot Used :This OID gives the receive power value read in the DDM (Digital Diagnostic Monitoring) of the XFP or OTX plugged in line #n (Unit = ?)
1.3.6.1.4.1.20044.32.3.3.224Tablepm1004vMesrotx1AgingTablenot-accessiblecurrentList of pm1004vMesrotx1Aging Article
1.3.6.1.4.1.20044.32.3.3.224.1Rowpm1004vMesrotx1AgingEntrynot-accessiblecurrentRow definition for the pm1004vMesrotx1Aging table
1.3.6.1.4.1.20044.32.3.3.224.1.1Columnpm1004vMesrotx1AgingIndexread-onlycurrentIndex definition for the pm1004vMesrotx1Aging table
1.3.6.1.4.1.20044.32.3.3.224.1.2Columnpm1004vMesrotx1AgingPortnread-onlycurrentLine OTX TLH Aging :This OID gives the aging of the Line OTX TLH, read from the DDM (Digital Diagnostic Monitoring) (Aging = AV) (Unit = %) <Help> This measure…
1.3.6.1.4.1.20044.32.3.3.225Tablepm1004vMesrotx1LaserTemperatureTablenot-accessibledeprecatedList of pm1004vMesrotx1LaserTemperature Article
1.3.6.1.4.1.20044.32.3.3.225.1Rowpm1004vMesrotx1LaserTemperatureEntrynot-accessibledeprecatedRow definition for the pm1004vMesrotx1LaserTemperature table
1.3.6.1.4.1.20044.32.3.3.225.1.1Columnpm1004vMesrotx1LaserTemperatureIndexread-onlydeprecatedIndex definition for the pm1004vMesrotx1LaserTemperature table
1.3.6.1.4.1.20044.32.3.3.225.1.2Columnpm1004vMesrotx1LaserTemperaturePortnread-onlydeprecatedLine OTX TLH Laser Temperature :This OID gives the laser temperature of the Line OTX TLH, read from the DDM (Digital Diagnostic Monitoring) (Temperature = AV/2…
1.3.6.1.4.1.20044.32.3.3.226Tablepm1004vMesrotx1FreqDeviationTablenot-accessiblecurrentList of pm1004vMesrotx1FreqDeviation Article
1.3.6.1.4.1.20044.32.3.3.226.1Rowpm1004vMesrotx1FreqDeviationEntrynot-accessiblecurrentRow definition for the pm1004vMesrotx1FreqDeviation table
1.3.6.1.4.1.20044.32.3.3.226.1.1Columnpm1004vMesrotx1FreqDeviationIndexread-onlycurrentIndex definition for the pm1004vMesrotx1FreqDeviation table
1.3.6.1.4.1.20044.32.3.3.226.1.2Columnpm1004vMesrotx1FreqDeviationPortnread-onlycurrentLine OTX TLH Frequency Deviation :This OID gives the frequency deviation of the Line OTX TLH, read from the DDM (Digital Diagnostic Monitoring) (Deviation = (A…
1.3.6.1.4.1.20044.32.3.3.227Tablepm1004vMesrotx1LaserWvlengthTablenot-accessiblecurrentList of pm1004vMesrotx1LaserWvlength Article
1.3.6.1.4.1.20044.32.3.3.227.1Rowpm1004vMesrotx1LaserWvlengthEntrynot-accessiblecurrentRow definition for the pm1004vMesrotx1LaserWvlength table
1.3.6.1.4.1.20044.32.3.3.227.1.1Columnpm1004vMesrotx1LaserWvlengthIndexread-onlycurrentIndex definition for the pm1004vMesrotx1LaserWvlength table
1.3.6.1.4.1.20044.32.3.3.227.1.2Columnpm1004vMesrotx1LaserWvlengthPortnread-onlycurrentLine Optical Module Wavelength :This OID gives the laser wavelength of the Line OTX TLH, read from the DDM (Digital Diagnostic Monitoring) (Wavelength=29979245…
1.3.6.1.4.1.20044.32.4Nodepm1004vcounters
1.3.6.1.4.1.20044.32.4.1Nodepm1004vCntOther
1.3.6.1.4.1.20044.32.4.2Nodepm1004vCntClient
1.3.6.1.4.1.20044.32.4.3Nodepm1004vCntLine
1.3.6.1.4.1.20044.32.4.3.152Tablepm1004vCntdfrmB1ErrCntTablenot-accessiblecurrentList of pm1004vCntdfrmB1ErrCnt Article
1.3.6.1.4.1.20044.32.4.3.152.1Rowpm1004vCntdfrmB1ErrCntEntrynot-accessiblecurrentRow definition for the pm1004vCntdfrmB1ErrCnt table
1.3.6.1.4.1.20044.32.4.3.152.1.1Columnpm1004vCntdfrmB1ErrCntIndexread-onlycurrentIndex definition for the pm1004vCntdfrmB1ErrCnt table
1.3.6.1.4.1.20044.32.4.3.152.1.2Columnpm1004vCntdfrmB1ErrCntValuePortnread-onlycurrentLine Input CRC Errors :This counter is incremented each time a B1 error is detected on the Deframer input stream. <Help> This counter gives the number of B1 er…
1.3.6.1.4.1.20044.32.4.3.152.1.3Columnpm1004vCntdfrmB1ErrCntErrorPortnread-onlycurrentLine Counter Error :This OID when set indicates the B1 error counter value is invalid on Port
1.3.6.1.4.1.20044.32.4.3.152.1.4Columnpm1004vCntdfrmB1ErrCntOverloadPortnread-onlycurrentLine Counter Overload :This OID when set indicates a B1 error counter overload on Port
1.3.6.1.4.1.20044.32.4.3.153Tablepm1004vCntdfrmTimCntTablenot-accessiblecurrentList of pm1004vCntdfrmTimCnt Article
1.3.6.1.4.1.20044.32.4.3.153.1Rowpm1004vCntdfrmTimCntEntrynot-accessiblecurrentRow definition for the pm1004vCntdfrmTimCnt table
1.3.6.1.4.1.20044.32.4.3.153.1.1Columnpm1004vCntdfrmTimCntIndexread-onlycurrentIndex definition for the pm1004vCntdfrmTimCnt table
1.3.6.1.4.1.20044.32.4.3.153.1.2Columnpm1004vCntdfrmTimCntValuePortnread-onlycurrentLine Timer Counter :This is the timing counter dedicated to the downstream deframer counters. It is incremented every 125 us.
1.3.6.1.4.1.20044.32.4.3.153.1.3Columnpm1004vCntdfrmTimCntErrorPortnread-onlycurrentLine Counter Error :This OID when set indicates the deframer timer counter value is invalid on Port
1.3.6.1.4.1.20044.32.4.3.153.1.4Columnpm1004vCntdfrmTimCntOverloadPortnread-onlycurrentLine Counter Overload :This OID when set indicates a deframer timer counter overload on Port
1.3.6.1.4.1.20044.32.4.259Scalarpm1004vCntCountersResetread-writecurrentCounters Reset:This OID resets and restarts all the counters
1.3.6.1.4.1.20044.32.4.260Scalarpm1004vCntCountersStopread-writecurrentCounters stop:This OID stops all the counters
1.3.6.1.4.1.20044.32.6Nodepm1004vcontrolsWrite
1.3.6.1.4.1.20044.32.6.1Nodepm1004vCtrlOther
1.3.6.1.4.1.20044.32.6.1.1Nodepm1004vCtrlconfMgnt1
1.3.6.1.4.1.20044.32.6.1.1.1Scalarpm1004vCtrlConf1Load1read-writecurrentLoad Configuration Tables Set Nb 1 :When set this OID enables loading from flash configuration1 into the PM.
1.3.6.1.4.1.20044.32.6.1.1.2Scalarpm1004vCtrlConf2Load1read-writecurrentLoad Configuration Tables Set Nb 2 :When set this OID enables loading from flash configuration2 into the PM.
1.3.6.1.4.1.20044.32.6.1.1.10Scalarpm1004vCtrlConf2Flash1read-writecurrentWrite Configuration Tables :This OID saves the current configuration of the PM as configuration2 in the flash. <Help> This control saves the customer configura…
1.3.6.1.4.1.20044.32.6.1.1.14Scalarpm1004vCtrlConf2Clear1read-writecurrentClear Configuration Tables :This OID clears the configuration tables from configuration2 in the flash. <Help> This control restores the default configuration o…
1.3.6.1.4.1.20044.32.6.1.4Nodepm1004vCtrlsynth4
1.3.6.1.4.1.20044.32.6.1.4.1Scalarpm1004vCtrlCorrelatOnread-writecurrentEnable Alarm Correlation :This OID enables the alarm correlation in the PM.
1.3.6.1.4.1.20044.32.6.1.4.2Scalarpm1004vCtrlCorrelatOffread-writecurrentDisable Alarm Correlation :This OID disables the alarm correlation in the PM.
1.3.6.1.4.1.20044.32.6.1.5Nodepm1004vCtrlswMgnt
1.3.6.1.4.1.20044.32.6.1.5.2Scalarpm1004vCtrlColdResetread-writecurrentPM Cold Reset :This OID, when set, causes a cold reset of the PM. This reset is traffic affecting, and the configuration of PM is reloaded on start-up. <Help> …
1.3.6.1.4.1.20044.32.6.1.5.3Scalarpm1004vCtrlWarmResetread-writecurrentPM Warm Reset :This OID, when set, causes a warm reset of the PM. This reset is not traffic affecting, and the configuration of PM remains unchanged. <Help> Th…
1.3.6.1.4.1.20044.32.6.1.5.5Scalarpm1004vCtrlLoadSwBank1read-writecurrentSet Software Nb 1 As Active :This OID, when set, loads the SW from bank1 into the PM. It must be followed by a reset. <Help> This controls selects the first SW…
1.3.6.1.4.1.20044.32.6.1.5.6Scalarpm1004vCtrlLoadSwBank2read-writecurrentSet Software Nb 2 As Active :This OID, when set, loads the SW from bank2 into the PM. It must be followed by a reset. <Help> This controls selects the second S…
1.3.6.1.4.1.20044.32.6.1.6Nodepm1004vCtrlgwMgnt
1.3.6.1.4.1.20044.32.6.1.6.1Scalarpm1004vCtrlCurrentGwResetread-writecurrentActive Gateware Reset :This OID, when set, resets the active gateware. It is traffic affecting.
1.3.6.1.4.1.20044.32.6.1.6.5Scalarpm1004vCtrlLoadGwBank1read-writecurrentSet Gateware Nb 1 As Active :This OID, when set, loads the GW from bank1 (Flash) into the PM. It is followed by an automatic gateware cold reset. <Help> This c…
1.3.6.1.4.1.20044.32.6.1.6.6Scalarpm1004vCtrlLoadGwBank2read-writecurrentSet Gateware Nb 2 As Active :This OID, when set, loads the GW from bank2 (Flash) into the PM. It is followed by an automatic gateware cold reset.
1.3.6.1.4.1.20044.32.6.1.6.7Scalarpm1004vCtrlLoadGwBank3read-writecurrentSet Gateware Nb 3 As Active :This OID, when set, loads the GW from bank3 (Flash) into the PM. It is followed by an automatic gateware cold reset. <Help> This c…
1.3.6.1.4.1.20044.32.6.1.6.8Scalarpm1004vCtrlLoadGwBank4read-writecurrentSet Gateware Nb 4 As Active :This OID, when set, loads the GW from bank4 (Flash) into the PM. It is followed by an automatic gateware cold reset.
1.3.6.1.4.1.20044.32.6.1.192Nodepm1004vCtrlledTest
1.3.6.1.4.1.20044.32.6.1.192.1Scalarpm1004vCtrlGreenLedread-writecurrentGreen Leds Test :This OID switches on all the green Leds as a test feature. <Help> This control initiates a test leds turning all the LEDs to green
1.3.6.1.4.1.20044.32.6.1.192.2Scalarpm1004vCtrlRedLedread-writecurrentRed Leds Test :This OID switches on all the red Leds as a test feature. <Help> This control initiates a test leds turning all the LEDs to red
1.3.6.1.4.1.20044.32.6.1.192.3Scalarpm1004vCtrlLedOffread-writecurrentLeds Off :This OID switches off all the Leds as a test feature. <Help> This control initiates a test leds turning all the LEDs to OFF
1.3.6.1.4.1.20044.32.6.1.193Nodepm1004vCtrlmoduleOosMode
1.3.6.1.4.1.20044.32.6.1.193.1Scalarpm1004vCtrlModuleOosModeread-writecurrentPM Out Of Service :This OID sets the PM Out Of Service <Help> This control defines the service state of the complete module
1.3.6.1.4.1.20044.32.6.1.197Nodepm1004vCtrlmaintenanceMode
1.3.6.1.4.1.20044.32.6.1.197.1Scalarpm1004vCtrlMaintenanceModeread-writecurrentModule Maintenance Mode :This OID enables the maintenance mode on the PM. <Help> This control enables the maintenance mode on the PM.
1.3.6.1.4.1.20044.32.6.2Nodepm1004vCtrlClient
1.3.6.1.4.1.20044.32.6.2.16Tablepm1004vCtrlaccessLoopTablenot-accessiblecurrentList of pm1004vCtrlaccessLoop Article
1.3.6.1.4.1.20044.32.6.2.16.1Rowpm1004vCtrlaccessLoopEntrynot-accessiblecurrentRow definition for the pm1004vCtrlaccessLoop table
1.3.6.1.4.1.20044.32.6.2.16.1.1Columnpm1004vCtrlaccessLoopIndexread-onlycurrentIndex definition for the pm1004vCtrlaccessLoop table
1.3.6.1.4.1.20044.32.6.2.16.1.2Columnpm1004vCtrlaccessLoopPortnread-writecurrentClient Facility Loopback :This OID operates a Client Facility Loopback, looping client input signal on the client output port. The loop is located on the clien…
1.3.6.1.4.1.20044.32.6.2.18Tablepm1004vCtrlportOosModeTablenot-accessiblecurrentList of pm1004vCtrlportOosMode Article
1.3.6.1.4.1.20044.32.6.2.18.1Rowpm1004vCtrlportOosModeEntrynot-accessiblecurrentRow definition for the pm1004vCtrlportOosMode table
1.3.6.1.4.1.20044.32.6.2.18.1.1Columnpm1004vCtrlportOosModeIndexread-onlycurrentIndex definition for the pm1004vCtrlportOosMode table
1.3.6.1.4.1.20044.32.6.2.18.1.2Columnpm1004vCtrlportOosModePortnread-writecurrentClient Out Of Service :This OID sets the Service state of the client port (In Service, Tx Out of Service, Rx Out of Service or Port (Rx and Tx) Out of Service)…
1.3.6.1.4.1.20044.32.6.2.20Tablepm1004vCtrlsfpOffCtrlTablenot-accessiblecurrentList of pm1004vCtrlsfpOffCtrl Article
1.3.6.1.4.1.20044.32.6.2.20.1Rowpm1004vCtrlsfpOffCtrlEntrynot-accessiblecurrentRow definition for the pm1004vCtrlsfpOffCtrl table
1.3.6.1.4.1.20044.32.6.2.20.1.1Columnpm1004vCtrlsfpOffCtrlIndexread-onlycurrentIndex definition for the pm1004vCtrlsfpOffCtrl table
1.3.6.1.4.1.20044.32.6.2.20.1.2Columnpm1004vCtrlsfpOffCtrlPortnread-writecurrentClient Signal Shutdown :This OID switches off the SFP. <Help> This control defines the laser state of the client transceiver
1.3.6.1.4.1.20044.32.6.2.21Tablepm1004vCtrlcsfUpInsTablenot-accessiblecurrentList of pm1004vCtrlcsfUpIns Article
1.3.6.1.4.1.20044.32.6.2.21.1Rowpm1004vCtrlcsfUpInsEntrynot-accessiblecurrentRow definition for the pm1004vCtrlcsfUpIns table
1.3.6.1.4.1.20044.32.6.2.21.1.1Columnpm1004vCtrlcsfUpInsIndexread-onlycurrentIndex definition for the pm1004vCtrlcsfUpIns table
1.3.6.1.4.1.20044.32.6.2.21.1.2Columnpm1004vCtrlcsfUpInsPortnread-writecurrentClient Signal Fail Insertion :This OID, when set, inserts a client signal fail in the upstream client Port. <Help> This control inserts a Client Signal Fail fo…
1.3.6.1.4.1.20044.32.6.2.22Tablepm1004vCtrlcaisDwInsTablenot-accessiblecurrentList of pm1004vCtrlcaisDwIns Article
1.3.6.1.4.1.20044.32.6.2.22.1Rowpm1004vCtrlcaisDwInsEntrynot-accessiblecurrentRow definition for the pm1004vCtrlcaisDwIns table
1.3.6.1.4.1.20044.32.6.2.22.1.1Columnpm1004vCtrlcaisDwInsIndexread-onlycurrentIndex definition for the pm1004vCtrlcaisDwIns table
1.3.6.1.4.1.20044.32.6.2.22.1.2Columnpm1004vCtrlcaisDwInsPortnread-writecurrentClient AIS Insertion :This OID, when set, inserts a client AIS on the downstream client Port. <Help> This control inserts a Client AIS for the client port
1.3.6.1.4.1.20044.32.6.2.26Tablepm1004vCtrlclientAccessTermLoopTablenot-accessiblecurrentList of pm1004vCtrlclientAccessTermLoop Article
1.3.6.1.4.1.20044.32.6.2.26.1Rowpm1004vCtrlclientAccessTermLoopEntrynot-accessiblecurrentRow definition for the pm1004vCtrlclientAccessTermLoop table
1.3.6.1.4.1.20044.32.6.2.26.1.1Columnpm1004vCtrlclientAccessTermLoopIndexread-onlycurrentIndex definition for the pm1004vCtrlclientAccessTermLoop table
1.3.6.1.4.1.20044.32.6.2.26.1.2Columnpm1004vCtrlclientAccessTermLoopPortnread-writecurrentClient Terminal Loopback :This OID operates a Client Terminal Loopback, looping client input signal on the client output port. The loop is located on the line …
1.3.6.1.4.1.20044.32.6.2.43Tablepm1004vCtrlrxVideoProtocolTablenot-accessiblecurrentList of pm1004vCtrlrxVideoProtocol Article
1.3.6.1.4.1.20044.32.6.2.43.1Rowpm1004vCtrlrxVideoProtocolEntrynot-accessiblecurrentRow definition for the pm1004vCtrlrxVideoProtocol table
1.3.6.1.4.1.20044.32.6.2.43.1.1Columnpm1004vCtrlrxVideoProtocolIndexread-onlycurrentIndex definition for the pm1004vCtrlrxVideoProtocol table
1.3.6.1.4.1.20044.32.6.2.43.1.2Columnpm1004vCtrlrxVideoProtocolPortnread-writecurrentForce DVB ASI On RX Side :This OID selects the DVB ASI protocol on the client port and disable the auto-sensing feature <Help> This control selects the DVB ASI…
1.3.6.1.4.1.20044.32.6.2.128Tablepm1004vCtrladddropClientRxProtectTablenot-accessiblecurrentList of pm1004vCtrladddropClientRxProtect Article
1.3.6.1.4.1.20044.32.6.2.128.1Rowpm1004vCtrladddropClientRxProtectEntrynot-accessiblecurrentRow definition for the pm1004vCtrladddropClientRxProtect table
1.3.6.1.4.1.20044.32.6.2.128.1.1Columnpm1004vCtrladddropClientRxProtectIndexread-onlycurrentIndex definition for the pm1004vCtrladddropClientRxProtect table
1.3.6.1.4.1.20044.32.6.2.128.1.2Columnpm1004vCtrladddropClientRxProtectPortnread-writecurrentClient Switch Mode :This bit selects the manual (1) or automatic (0) switch method <Help> This control defines the protection switch mode on the client interfa…
1.3.6.1.4.1.20044.32.6.2.136Tablepm1004vCtrladddropTsClientModeTablenot-accessiblecurrentList of pm1004vCtrladddropTsClientMode Article
1.3.6.1.4.1.20044.32.6.2.136.1Rowpm1004vCtrladddropTsClientModeEntrynot-accessiblecurrentRow definition for the pm1004vCtrladddropTsClientMode table
1.3.6.1.4.1.20044.32.6.2.136.1.1Columnpm1004vCtrladddropTsClientModeIndexread-onlycurrentIndex definition for the pm1004vCtrladddropTsClientMode table
1.3.6.1.4.1.20044.32.6.2.136.1.2Columnpm1004vCtrladddropTsClientModePortnread-writecurrentClient Mode :This OID selects the mode on the client <Help> This control defines the mode (Add/Drop or Split&Select) of the Client
1.3.6.1.4.1.20044.32.6.3Nodepm1004vCtrlLine
1.3.6.1.4.1.20044.32.6.3.64Nodepm1004vCtrlcommAccessLoop
1.3.6.1.4.1.20044.32.6.3.64.1Scalarpm1004vCtrlCommAccessloopread-writedeprecatedPM Full Access Loop Mode :This OID, when set, puts the module in common access loop back, looping the 10 Gb/s output signal on the 10 Gb/s input.
1.3.6.1.4.1.20044.32.6.3.66Nodepm1004vCtrllineLoop
1.3.6.1.4.1.20044.32.6.3.66.1Scalarpm1004vCtrlLineLoopread-writedeprecatedPM Line Loop Mode :This OID, when set at '1' puts the module in line loopback mode, looping the received 10 Gb/s signal on the transmit 10 Gb/s output. The Ups…
1.3.6.1.4.1.20044.32.6.3.73Nodepm1004vCtrlProtMgnt
1.3.6.1.4.1.20044.32.6.3.73.1Scalarpm1004vCtrlLineNumberread-writecurrentActive Line Number : This OID sets the active line number
1.3.6.1.4.1.20044.32.6.3.73.2Scalarpm1004vCtrlProtModeread-writecurrentLine Switch Mode (Auto Or Manual) :This bit selects the manual (1) or automatic (0) switch method <Help> This control defines the protection switch mode on the…
1.3.6.1.4.1.20044.32.6.3.74Tablepm1004vCtrllineOosModeTablenot-accessiblecurrentList of pm1004vCtrllineOosMode Article
1.3.6.1.4.1.20044.32.6.3.74.1Rowpm1004vCtrllineOosModeEntrynot-accessiblecurrentRow definition for the pm1004vCtrllineOosMode table
1.3.6.1.4.1.20044.32.6.3.74.1.1Columnpm1004vCtrllineOosModeIndexread-onlycurrentIndex definition for the pm1004vCtrllineOosMode table
1.3.6.1.4.1.20044.32.6.3.74.1.2Columnpm1004vCtrllineOosModePortnread-writecurrentLine Out Of Service (!Laser OFF!) :This OID sets the line port Out Of Service <Help> This control defines the service state of the line port
1.3.6.1.4.1.20044.32.6.3.198Tablepm1004vCtrldccEnableTablenot-accessiblecurrentList of pm1004vCtrldccEnable Article
1.3.6.1.4.1.20044.32.6.3.198.1Rowpm1004vCtrldccEnableEntrynot-accessiblecurrentRow definition for the pm1004vCtrldccEnable table
1.3.6.1.4.1.20044.32.6.3.198.1.1Columnpm1004vCtrldccEnableIndexread-onlycurrentIndex definition for the pm1004vCtrldccEnable table
1.3.6.1.4.1.20044.32.6.3.198.1.2Columnpm1004vCtrldccEnablePortnread-writecurrentDCC Enable : This OID enables the DCC mode on the PM <Help> This control enables the DCC mode on the PM
1.3.6.1.4.1.20044.32.6.3.208Tablepm1004vCtrlxfpOnoffTablenot-accessiblecurrentList of pm1004vCtrlxfpOnoff Article
1.3.6.1.4.1.20044.32.6.3.208.1Rowpm1004vCtrlxfpOnoffEntrynot-accessiblecurrentRow definition for the pm1004vCtrlxfpOnoff table
1.3.6.1.4.1.20044.32.6.3.208.1.1Columnpm1004vCtrlxfpOnoffIndexread-onlycurrentIndex definition for the pm1004vCtrlxfpOnoff table
1.3.6.1.4.1.20044.32.6.3.208.1.2Columnpm1004vCtrlxfpOnoffPortnread-writecurrentLine Optical Module Laser Shutdown :This OID switches off the XFP or the OTX <Help> This control defines the laser state of the line transceiver
1.3.6.1.4.1.20044.32.6.3.209Tablepm1004vCtrlxfpLineLoopTablenot-accessiblecurrentList of pm1004vCtrlxfpLineLoop Article
1.3.6.1.4.1.20044.32.6.3.209.1Rowpm1004vCtrlxfpLineLoopEntrynot-accessiblecurrentRow definition for the pm1004vCtrlxfpLineLoop table
1.3.6.1.4.1.20044.32.6.3.209.1.1Columnpm1004vCtrlxfpLineLoopIndexread-onlycurrentIndex definition for the pm1004vCtrlxfpLineLoop table
1.3.6.1.4.1.20044.32.6.3.209.1.2Columnpm1004vCtrlxfpLineLoopPortnread-writecurrentLine Facility Loopback :This OID operates a Line Facility Loopback, looping line input signal on the line output port. The loop is located on the line transcei…
1.3.6.1.4.1.20044.32.6.3.210Tablepm1004vCtrlxfpXfiLoopTablenot-accessiblecurrentList of pm1004vCtrlxfpXfiLoop Article
1.3.6.1.4.1.20044.32.6.3.210.1Rowpm1004vCtrlxfpXfiLoopEntrynot-accessiblecurrentRow definition for the pm1004vCtrlxfpXfiLoop table
1.3.6.1.4.1.20044.32.6.3.210.1.1Columnpm1004vCtrlxfpXfiLoopIndexread-onlycurrentIndex definition for the pm1004vCtrlxfpXfiLoop table
1.3.6.1.4.1.20044.32.6.3.210.1.2Columnpm1004vCtrlxfpXfiLoopPortnread-writecurrentLine Terminal Loopback :This OID operates a Line Terminal Loopback, looping line input signal on the line output port. The loop is located on all client transc…
1.3.6.1.4.1.20044.32.7Nodepm1004vri
1.3.6.1.4.1.20044.32.7.1Nodepm1004vriTable
1.3.6.1.4.1.20044.32.7.1.1Tablepm1004vRinvSfpTablenot-accessiblecurrentList of the SFPs on the selected module
1.3.6.1.4.1.20044.32.7.1.1.1Rowpm1004vRinvSfpEntrynot-accessiblecurrentRow definition for the SFP table
1.3.6.1.4.1.20044.32.7.1.1.1.1Columnpm1004vRinvSfpIndexread-onlycurrentIndex for SFP table
1.3.6.1.4.1.20044.32.7.1.1.1.2Columnpm1004vRinvsfpread-onlycurrentInventory for the SFP: This OID contains the inventory for the SFP
1.3.6.1.4.1.20044.32.7.1.2Tablepm1004vRinvLineTablenot-accessiblecurrentList of the XFPs on the selected module
1.3.6.1.4.1.20044.32.7.1.2.1Rowpm1004vRinvLineEntrynot-accessiblecurrentRow definition for the XFP table
1.3.6.1.4.1.20044.32.7.1.2.1.1Columnpm1004vRinvLineIndexread-onlycurrentIndex for XFP table
1.3.6.1.4.1.20044.32.7.1.2.1.2Columnpm1004vRinvxfpLineread-onlycurrentInventory for the XFP: This OID contains the inventory for the XFP
1.3.6.1.4.1.20044.32.7.2Scalarpm1004vRinvReloadInventoryread-writecurrentReload the inventory: This OID triggers an inventory reload.
1.3.6.1.4.1.20044.32.7.3Scalarpm1004vRinvHwPlatformread-onlycurrentHW platform description: This OID contains the description of the Hardware platform.
1.3.6.1.4.1.20044.32.7.4Scalarpm1004vRinvModulePlatformread-onlycurrentModule platform description: This OID contains the description of the Module.
1.3.6.1.4.1.20044.32.7.5Scalarpm1004vRinvSwPlatformread-onlycurrentSW platform description: This OID contains the description of the Software platform.
1.3.6.1.4.1.20044.32.7.6Scalarpm1004vRinvGwPlatformread-onlycurrentGW platform desciption: This OID contains the description of the Gateware platform.
1.3.6.1.4.1.20044.32.8Nodepm1004vdownload
1.3.6.1.4.1.20044.32.8.1Nodepm1004vDwlOther
1.3.6.1.4.1.20044.32.8.1.0Nodepm1004vDwlrestartProcess
1.3.6.1.4.1.20044.32.8.1.0.1Scalarpm1004vDwlWarmRestartProcessedread-onlycurrentWarm Restart :This OID indicates that the module last restart was a Warm RESTART
1.3.6.1.4.1.20044.32.8.1.0.2Scalarpm1004vDwlColdRestartProcessedread-onlycurrentCold Restart :This OID indicates that the module last restart was a Cold RESTART
1.3.6.1.4.1.20044.32.8.1.1Nodepm1004vDwlswBanksUsed
1.3.6.1.4.1.20044.32.8.1.1.1Scalarpm1004vDwlSwBank1Usedread-onlycurrentSW bank 1 active :This OID indicates the module is working on SW bank 1 <Help> This status indicates if the SW bank 1 is active or standby
1.3.6.1.4.1.20044.32.8.1.1.2Scalarpm1004vDwlSwBank2Usedread-onlycurrentSW bank 2 active :This OID indicates the module is working on SW bank 2 <Help> This status indicates if the SW bank 2 is active or standby
1.3.6.1.4.1.20044.32.8.1.1.5Scalarpm1004vDwlSwBank1Notemptyread-onlycurrentSW bank 1 loaded :This OID indicates a software is loaded in SW bank 1 <Help> This status indicates if the SW bank 1 contains SW package
1.3.6.1.4.1.20044.32.8.1.1.6Scalarpm1004vDwlSwBank2Notemptyread-onlycurrentSW bank 2 loaded :This OID indicates a software is loaded in SW bank 2 <Help> This status indicates if the SW bank 2 contains SW package
1.3.6.1.4.1.20044.32.8.1.2Nodepm1004vDwlgwBanksUsed
1.3.6.1.4.1.20044.32.8.1.2.1Scalarpm1004vDwlGwBank1Usedread-onlycurrentGW bank 1 active :This OID indicates the module is working on GW bank 1 <Help> This status indicates if the GW bank 1 is active or standby
1.3.6.1.4.1.20044.32.8.1.2.2Scalarpm1004vDwlGwBank2Usedread-onlycurrentGW bank 2 active :This OID indicates the module is working on GW bank 2
1.3.6.1.4.1.20044.32.8.1.2.3Scalarpm1004vDwlGwBank3Usedread-onlycurrentGW bank 3 active :This OID indicates the module is working on GW bank 3 <Help> This status indicates if the GW bank 3 is active or standby
1.3.6.1.4.1.20044.32.8.1.2.4Scalarpm1004vDwlGwBank4Usedread-onlycurrentGW bank 4 active :This OID indicates the module is working on GW bank 4
1.3.6.1.4.1.20044.32.8.1.2.5Scalarpm1004vDwlGwBank1Notemptyread-onlycurrentGW bank 1 loaded :This OID indicates a gateware is loaded in GW bank 1 <Help> This status indicates if the GW bank 1 contains GW package
1.3.6.1.4.1.20044.32.8.1.2.6Scalarpm1004vDwlGwBank2Notemptyread-onlycurrentGW bank 2 loaded :This OID indicates a gateware is loaded in GW bank 2
1.3.6.1.4.1.20044.32.8.1.2.7Scalarpm1004vDwlGwBank3Notemptyread-onlycurrentGW bank 3 loaded :This OID indicates a gateware is loaded in GW bank 3 <Help> This status indicates if the GW bank 3 contains GW package
1.3.6.1.4.1.20044.32.8.1.2.8Scalarpm1004vDwlGwBank4Notemptyread-onlycurrentGW bank 4 loaded :This OID indicates a gateware is loaded in GW bank 4
1.3.6.1.4.1.20044.32.8.2Nodepm1004vDwlClient
1.3.6.1.4.1.20044.32.8.3Nodepm1004vDwlLine
1.3.6.1.4.1.20044.32.9Nodepm1004vConfig
1.3.6.1.4.1.20044.32.9.1Nodepm1004vCfgAccessCAisCsf
1.3.6.1.4.1.20044.32.9.1.1Tablepm1004vCfgClientcaiscsfTablenot-accessiblecurrentList of Article
1.3.6.1.4.1.20044.32.9.1.1.1Rowpm1004vCfgClientcaiscsfEntrynot-accessiblecurrentRow definition for the accessCAisCsf table
1.3.6.1.4.1.20044.32.9.1.1.1.1Columnpm1004vCfgClientcaiscsfIndexread-onlycurrentIndex definition for the clientcaiscsf table
1.3.6.1.4.1.20044.32.9.1.1.1.3Columnpm1004vCfgCAisModePortnread-writecurrentCAIS mode on Client Port :This register enables/disables port laser shutdown on CAIS insertion condition
1.3.6.1.4.1.20044.32.9.1.1.1.9Columnpm1004vCfgUpAccessioAlmPortnread-writecurrentCSF contributors on Client Port :This register configures the contributors to upstream CSF insertion on the port.
1.3.6.1.4.1.20044.32.9.1.1.1.10Columnpm1004vCfgUpMapperDeAlmPortnread-writecurrentCSF contributors on Client Port :This register configures the contributors to upstream CSF insertion on the port.
1.3.6.1.4.1.20044.32.9.1.1.1.17Columnpm1004vCfgDownAccessioAlmPortnread-writecurrentCAIS contributors on Client Port :This register configures the contributors to downstream CAIS insertion on port.
1.3.6.1.4.1.20044.32.9.1.1.1.18Columnpm1004vCfgDownMapperDeAlmPortnread-writecurrentCAIS contributors on Client Port :This register configures the contributors to downstream CAIS insertion on port.
1.3.6.1.4.1.20044.32.9.1.1.1.19Columnpm1004vCfgDownDfrmAlmPortnread-writecurrentCAIS contributors on Client Port :This register configures the contributors to downstream CAIS insertion on port.
1.3.6.1.4.1.20044.32.9.1.1.1.20Columnpm1004vCfgDownLineSyncAlarmsPortnread-writedeprecatedCAIS contributors on Client Port :This register configures the contributors to downstream CAIS insertion on port.
1.3.6.1.4.1.20044.32.9.2Nodepm1004vCfgStartup
1.3.6.1.4.1.20044.32.9.2.1Tablepm1004vCfgClientStartupTablenot-accessiblecurrentList of Article
1.3.6.1.4.1.20044.32.9.2.1.1Rowpm1004vCfgClientStartupEntrynot-accessiblecurrentRow definition for the startup table
1.3.6.1.4.1.20044.32.9.2.1.1.1Columnpm1004vCfgClientStartupIndexread-onlycurrentIndex definition for the clientStartup table
1.3.6.1.4.1.20044.32.9.2.1.1.3Columnpm1004vCfgSystConfPortPortnread-writecurrentDefault Settings on Client Port :This register configures the default initialisation settings on the port.
1.3.6.1.4.1.20044.32.9.2.1.1.4Columnpm1004vCfgNetConfPortPortnread-writecurrentDefault Protocol on Client Port :This register configures the default initialisation protocol on the port.
1.3.6.1.4.1.20044.32.9.2.1.1.5Columnpm1004vCfgAdddropConfPortPortnread-writedeprecatedDefault Add&Drop mode on Client Port :This register configures the default Add&Drop mode on the port.
1.3.6.1.4.1.20044.32.9.2.2Nodepm1004vtablelineStartup
1.3.6.1.4.1.20044.32.9.2.2.2Scalarpm1004vCfgsystConfLine1read-writecurrentDefault Settings on Line 1 :This register configures the default initialisation settings on Line port 1.
1.3.6.1.4.1.20044.32.9.2.2.5Scalarpm1004vCfglineOptions1read-writecurrentDefault Options on Active Line Port :This register configures the default options on the active line port
1.3.6.1.4.1.20044.32.9.2.2.6Scalarpm1004vCfgsystConfLine2read-writecurrentDefault Settings on Line 2 :This register configures the default initialisation settings on Line port 2.
1.3.6.1.4.1.20044.32.9.2.2.7Scalarpm1004vCfglineSelectionread-writecurrentDefault Settings of active line :This register configures the start up active line.
1.3.6.1.4.1.20044.32.9.2.2.9Scalarpm1004vCfglineOptions2read-writecurrentDefault Options on Active Line Port :This register configures the default options on the active line port
1.3.6.1.4.1.20044.32.9.2.3Tablepm1004vCfgXfpTablenot-accessiblecurrentList of Article
1.3.6.1.4.1.20044.32.9.2.3.1Rowpm1004vCfgXfpEntrynot-accessiblecurrentRow definition for the startup table
1.3.6.1.4.1.20044.32.9.2.3.1.1Columnpm1004vCfgXfpIndexread-onlycurrentIndex definition for the xfp table
1.3.6.1.4.1.20044.32.9.2.3.1.3Columnpm1004vCfgSystConfXfpPortnread-writecurrentDefault settings on XFP Port :This register configures the default initialisation settings on XFP port.
1.3.6.1.4.1.20044.32.9.2.3.1.4Columnpm1004vCfgDataRateConfXfpPortnread-writedeprecated:
1.3.6.1.4.1.20044.32.9.3Nodepm1004vCfgLabels
1.3.6.1.4.1.20044.32.9.3.1Tablepm1004vCfgLabelclientTablenot-accessiblecurrentList of Article
1.3.6.1.4.1.20044.32.9.3.1.1Rowpm1004vCfgLabelclientEntrynot-accessiblecurrentRow definition for the labels table
1.3.6.1.4.1.20044.32.9.3.1.1.1Columnpm1004vCfgLabelclientIndexread-onlycurrentIndex definition for the labelclient table
1.3.6.1.4.1.20044.32.9.3.1.1.3Columnpm1004vCfgLabelclientPortnread-writecurrentDefault settings on the label of the Ports :These registers configures the default initialisation settings of the labels of the ports.
1.3.6.1.4.1.20044.32.9.3.2Tablepm1004vCfgLabellineTablenot-accessiblecurrentList of Article
1.3.6.1.4.1.20044.32.9.3.2.1Rowpm1004vCfgLabellineEntrynot-accessiblecurrentRow definition for the labels table
1.3.6.1.4.1.20044.32.9.3.2.1.1Columnpm1004vCfgLabellineIndexread-onlycurrentIndex definition for the labelline table
1.3.6.1.4.1.20044.32.9.3.2.1.3Columnpm1004vCfgLabellinePortnread-writecurrentDefault settings on the label of the lines :These registers configures the default initialisation settings of the labels of the lines.
1.3.6.1.4.1.20044.32.9.4Nodepm1004vCfgStartupthresholds
1.3.6.1.4.1.20044.32.9.4.1Tablepm1004vCfgClientStartupThreshTablenot-accessiblecurrentList of Article
1.3.6.1.4.1.20044.32.9.4.1.1Rowpm1004vCfgClientStartupThreshEntrynot-accessiblecurrentRow definition for the startupthresholds table
1.3.6.1.4.1.20044.32.9.4.1.1.1Columnpm1004vCfgClientStartupThreshIndexread-onlycurrentIndex definition for the clientStartupThresh table
1.3.6.1.4.1.20044.32.9.4.1.1.15Columnpm1004vCfgClientThreshtxpowhighPortnread-writecurrentDefault Setting on Tx Power high threshold :This register configures the default initialisation of the high threshold of the Transmit power on the port.
1.3.6.1.4.1.20044.32.9.4.1.1.16Columnpm1004vCfgClientThreshtxpowlowPortnread-writecurrentDefault Setting on Tx Power low threshold :This register configures the default initialisation of the low threshold of the Transmit power on the port.
1.3.6.1.4.1.20044.32.9.4.1.1.19Columnpm1004vCfgClientThreshrxpowhighPortnread-writecurrentDefault Setting on Rx Power high threshold :This register configures the default initialisation of the high threshold of the received power on the port.
1.3.6.1.4.1.20044.32.9.4.1.1.20Columnpm1004vCfgClientThreshrxpowlowPortnread-writecurrentDefault Setting on Rx Power low threshold :This register configures the default initialisation of the low threshold of the received power on the port.
1.3.6.1.4.1.20044.32.9.4.2Tablepm1004vCfgLineStartupThreshTablenot-accessiblecurrentList of Article
1.3.6.1.4.1.20044.32.9.4.2.1Rowpm1004vCfgLineStartupThreshEntrynot-accessiblecurrentRow definition for the startupthresholds table
1.3.6.1.4.1.20044.32.9.4.2.1.1Columnpm1004vCfgLineStartupThreshIndexread-onlycurrentIndex definition for the lineStartupThresh table
1.3.6.1.4.1.20044.32.9.4.2.1.15Columnpm1004vCfgLineThreshtxpowhighPortnread-writecurrentDefault Setting on Tx Power high threshold :This register configures the default initialisation of the high threshold of the Transmit power on the line.
1.3.6.1.4.1.20044.32.9.4.2.1.16Columnpm1004vCfgLineThreshtxpowlowPortnread-writecurrentDefault Setting on Tx Power low threshold :This register configures the default initialisation of the low threshold of the Transmit power on the line.
1.3.6.1.4.1.20044.32.9.4.2.1.19Columnpm1004vCfgLineThreshrxpowhighPortnread-writecurrentDefault Setting on Rx Power high threshold :This register configures the default initialisation of the high threshold of the received power on the line.
1.3.6.1.4.1.20044.32.9.4.2.1.20Columnpm1004vCfgLineThreshrxpowlowPortnread-writecurrentDefault Setting on Rx Power low threshold :This register configures the default initialisation of the low threshold of the received power on the line.
1.3.6.1.4.1.20044.32.9.5Nodepm1004vCfgStartuptlh
1.3.6.1.4.1.20044.32.9.5.1Tablepm1004vCfgOtxtlhTablenot-accessiblecurrentList of Article
1.3.6.1.4.1.20044.32.9.5.1.1Rowpm1004vCfgOtxtlhEntrynot-accessiblecurrentRow definition for the startuptlh table
1.3.6.1.4.1.20044.32.9.5.1.1.1Columnpm1004vCfgOtxtlhIndexread-onlycurrentIndex definition for the otxtlh table
1.3.6.1.4.1.20044.32.9.5.1.1.3Columnpm1004vCfgNuPortnread-writedeprecated:
1.3.6.1.4.1.20044.32.9.5.1.1.4Columnpm1004vCfgLineDitherRatePortnread-writecurrentDefault Line OTX TLH FM amplitude :This register configures the start-up width of the frequency modulation of the Line OTX TLH
1.3.6.1.4.1.20044.32.9.5.1.1.5Columnpm1004vCfgLineDitherFhzPortnread-writecurrentDefault Line OTX TLH FM frequency :This register configures the start-up frequency of the frequency modulation of the Line OTX TLH
1.3.6.1.4.1.20044.32.9.5.1.1.6Columnpm1004vCfgLinePwrLaserPortnread-writecurrentDefaut Line OTX TLH output Power :This register configures the start-up output power of the Line OTX TLH (Unit = dBm)
1.3.6.1.4.1.20044.32.9.5.1.1.7Columnpm1004vCfgLineFCurrentPortnread-writecurrentDefault Line OTX TLH Channel :This register configures the start-up laser channel of the Line OTX TLH
1.3.6.1.4.1.20044.32.9.5.1.1.8Columnpm1004vCfgLineGridCurrentPortnread-writecurrentDefault Line OTX TLH Grid :This register configures the start-up laser grid of the Line OTX TLH
1.3.6.1.4.1.20044.32.9.5.1.1.9Columnpm1004vCfgFPortnread-writecurrentDefault Line OTX TLH lowest Freq :This register configures the start-up lowest frequency supported on the Line OTX TLH
1.3.6.1.4.1.20044.32.9.5.1.1.10Columnpm1004vCfgReservedPortnread-writedeprecated:
1.3.6.1.4.1.20044.32.9.5.1.1.11Columnpm1004vCfgLinePhotodiodeModePortnread-writecurrentDefault Line OTX TLH APD mode :This register configures the start-up APD mode of the Line OTX TLH
1.3.6.1.4.1.20044.32.9.5.1.1.12Columnpm1004vCfgLinePhotodiodeValuePortnread-writecurrentDefault Line OTX TLH APD atten. :This register configures the start-up APD attenuation on the Line OTX TLH
1.3.6.1.4.1.20044.32.9.6Nodepm1004vCfgStartuptablefive
1.3.6.1.4.1.20044.32.9.6.1Tablepm1004vCfgOtxtlhcapabilitiesTablenot-accessiblecurrentList of Article
1.3.6.1.4.1.20044.32.9.6.1.1Rowpm1004vCfgOtxtlhcapabilitiesEntrynot-accessiblecurrentRow definition for the startuptablefive table
1.3.6.1.4.1.20044.32.9.6.1.1.1Columnpm1004vCfgOtxtlhcapabilitiesIndexread-onlycurrentIndex definition for the otxtlhcapabilities table
1.3.6.1.4.1.20044.32.9.6.1.1.3Columnpm1004vCfgComponentTypePortnread-onlycurrentComponent parameters :This OID defines the component parameters
1.3.6.1.4.1.20044.32.9.6.1.1.4Columnpm1004vCfgMiscellaneousPortnread-onlycurrentMiscellaneous default settings :This OID defines the miscellaneous parameters
1.3.6.1.4.1.20044.32.9.6.1.1.5Columnpm1004vCfgFirstChannelPortnread-onlycurrentNumber of the first channel of the component :This OID defines the first channel number of the PM
1.3.6.1.4.1.20044.32.9.6.1.1.6Columnpm1004vCfgLastChannelPortnread-onlycurrentNumber of the last channel of the component :This OID defines the last channel number of the PM
1.3.6.1.4.1.20044.32.9.6.1.1.7Columnpm1004vCfgGridPortnread-onlycurrentGrid value of the component :This OID defines the grid of the PM
1.3.6.1.4.1.20044.32.9.257Scalarpm1004vCfgWriteConfigurationread-writecurrentWrite configuration to module:This OID writes the complete configuration to the module
1.3.6.1.4.1.20044.32.10Nodepm1004vtraps
1.3.6.1.4.1.20044.32.10.2Scalarpm1004vtrapPortNumberread-onlycurrentLast port which generates a trap
1.3.6.1.4.1.20044.32.10.3Scalarpm1004vtrapLineNumberread-onlycurrentLast Line which generates a trap
1.3.6.1.4.1.20044.32.10.4Scalarpm1004vtrapBoardNumberread-onlycurrentLast module which generates a trap
1.3.6.1.4.1.20044.32.10.30Notificationpm1004vLineTrapNotUrgentGoesOncurrentNot urgent Line default is activated
1.3.6.1.4.1.20044.32.10.31Notificationpm1004vLineTrapNotUrgentGoesOffcurrentNot urgent Line default disappeared
1.3.6.1.4.1.20044.32.10.32Notificationpm1004vLineTrapUrgentGoesOncurrentUrgent Line default is activated
1.3.6.1.4.1.20044.32.10.33Notificationpm1004vLineTrapUrgentGoesOffcurrentUrgent Line default disappeared
1.3.6.1.4.1.20044.32.10.34Notificationpm1004vLineTrapCritGoesOncurrentCritical Line default is activated
1.3.6.1.4.1.20044.32.10.35Notificationpm1004vLineTrapCritGoesOffcurrentCritical Line default disappeared
1.3.6.1.4.1.20044.32.10.40Notificationpm1004vClientTrapNotUrgentGoesOncurrentNot urgent client default is activated
1.3.6.1.4.1.20044.32.10.41Notificationpm1004vClientTrapNotUrgentGoesOffcurrentNot urgent client default disappeared
1.3.6.1.4.1.20044.32.10.42Notificationpm1004vClientTrapUrgentGoesOncurrentUrgent client default is activated
1.3.6.1.4.1.20044.32.10.43Notificationpm1004vClientTrapUrgentGoesOffcurrentUrgent client default disappeared
1.3.6.1.4.1.20044.32.10.44Notificationpm1004vClientTrapCritGoesOncurrentCritical client default is activated
1.3.6.1.4.1.20044.32.10.45Notificationpm1004vClientTrapCritGoesOffcurrentCritical client default disappeared
1.3.6.1.4.1.20044.32.10.50Notificationpm1004vPowerTrapUrgentGoesOncurrentUrgent power supply default is activated
1.3.6.1.4.1.20044.32.10.51Notificationpm1004vPowerTrapUrgentGoesOffcurrentUrgent power supply default disappeared
1.3.6.1.4.1.20044.32.11Nodepm1004vMonitoring
1.3.6.1.4.1.20044.32.11.1Nodepm1004vMonOther
1.3.6.1.4.1.20044.32.11.1.3Nodepm1004vMonRmon
1.3.6.1.4.1.20044.32.11.1.3.359Scalarpm1004vMonCountersResetread-writecurrentRMON Counters Reset:This OID resets and restarts all the RMON counters
1.3.6.1.4.1.20044.32.11.1.3.360Scalarpm1004vMonCountersStopread-writecurrentRMON Counters stop:This OID stops all the RMON counters
1.3.6.1.4.1.20044.32.11.2Nodepm1004vMonClient
1.3.6.1.4.1.20044.32.11.2.4Nodepm1004vMonClientRmonCounter
1.3.6.1.4.1.20044.32.11.2.4.16Tablepm1004vMonupRmonByteCntTablenot-accessiblecurrentList of pm1004vMonupRmonByteCnt Article
1.3.6.1.4.1.20044.32.11.2.4.16.1Rowpm1004vMonupRmonByteCntEntrynot-accessiblecurrentRow definition for the pm1004vMonupRmonByteCnt table
1.3.6.1.4.1.20044.32.11.2.4.16.1.1Columnpm1004vMonupRmonByteCntIndexread-onlycurrentIndex definition for the pm1004vMonupRmonByteCnt table
1.3.6.1.4.1.20044.32.11.2.4.16.1.2Columnpm1004vMonupRmonByteCntValuePortnread-onlycurrentClient Input Bytes :This counter is increased each time a data byte is received on the client port <Help> This counter gives the number of bytes received on th…
1.3.6.1.4.1.20044.32.11.2.4.16.1.3Columnpm1004vMonupRmonByteCntErrorPortnread-onlycurrentBytes Counter Error :This OID when set indicates the Bytes counter value is invalid on clinet port
1.3.6.1.4.1.20044.32.11.2.4.16.1.4Columnpm1004vMonupRmonByteCntOverloadPortnread-onlycurrentBytes Counter Overload :This OID when set indicates a Bytes counter overload on client port
1.3.6.1.4.1.20044.32.11.2.4.24Tablepm1004vMonupRmonCrcErrorCntTablenot-accessiblecurrentList of pm1004vMonupRmonCrcErrorCnt Article
1.3.6.1.4.1.20044.32.11.2.4.24.1Rowpm1004vMonupRmonCrcErrorCntEntrynot-accessiblecurrentRow definition for the pm1004vMonupRmonCrcErrorCnt table
1.3.6.1.4.1.20044.32.11.2.4.24.1.1Columnpm1004vMonupRmonCrcErrorCntIndexread-onlycurrentIndex definition for the pm1004vMonupRmonCrcErrorCnt table
1.3.6.1.4.1.20044.32.11.2.4.24.1.2Columnpm1004vMonupRmonCrcErrorCntValuePortnread-onlycurrentClient Input CRC Errors :This counter is increased each time a CRC error is detected on the client port <Help> This counter gives the number of CRC Errors rece…
1.3.6.1.4.1.20044.32.11.2.4.24.1.3Columnpm1004vMonupRmonCrcErrorCntErrorPortnread-onlycurrentCRC Errors Counter Error :This OID when set indicates the CRC Errors counter value is invalid on clinet port
1.3.6.1.4.1.20044.32.11.2.4.24.1.4Columnpm1004vMonupRmonCrcErrorCntOverloadPortnread-onlycurrentCRC Errors Counter Overload :This OID when set indicates a CRC Errors counter overload on client port
1.3.6.1.4.1.20044.32.11.2.4.32Tablepm1004vMonupRmonPacketsCntTablenot-accessiblecurrentList of pm1004vMonupRmonPacketsCnt Article
1.3.6.1.4.1.20044.32.11.2.4.32.1Rowpm1004vMonupRmonPacketsCntEntrynot-accessiblecurrentRow definition for the pm1004vMonupRmonPacketsCnt table
1.3.6.1.4.1.20044.32.11.2.4.32.1.1Columnpm1004vMonupRmonPacketsCntIndexread-onlycurrentIndex definition for the pm1004vMonupRmonPacketsCnt table
1.3.6.1.4.1.20044.32.11.2.4.32.1.2Columnpm1004vMonupRmonPacketsCntValuePortnread-onlycurrentClient Input Packets :This counter is increased each time a packet is received on the client port <Help> This counter gives the number of packets received on t…
1.3.6.1.4.1.20044.32.11.2.4.32.1.3Columnpm1004vMonupRmonPacketsCntErrorPortnread-onlycurrentPackets Counter Error :This OID when set indicates the Packets counter value is invalid on clinet port
1.3.6.1.4.1.20044.32.11.2.4.32.1.4Columnpm1004vMonupRmonPacketsCntOverloadPortnread-onlycurrentPackets Counter Overload :This OID when set indicates a Packets counter overload on client port
1.3.6.1.4.1.20044.32.11.2.4.40Tablepm1004vMonupRmonBroadcastCntTablenot-accessiblecurrentList of pm1004vMonupRmonBroadcastCnt Article
1.3.6.1.4.1.20044.32.11.2.4.40.1Rowpm1004vMonupRmonBroadcastCntEntrynot-accessiblecurrentRow definition for the pm1004vMonupRmonBroadcastCnt table
1.3.6.1.4.1.20044.32.11.2.4.40.1.1Columnpm1004vMonupRmonBroadcastCntIndexread-onlycurrentIndex definition for the pm1004vMonupRmonBroadcastCnt table
1.3.6.1.4.1.20044.32.11.2.4.40.1.2Columnpm1004vMonupRmonBroadcastCntValuePortnread-onlycurrentClient Input Broadcast Packets :This counter is increased each time a broadcast packet is received on the client port <Help> This counter gives the number of B…
1.3.6.1.4.1.20044.32.11.2.4.40.1.3Columnpm1004vMonupRmonBroadcastCntErrorPortnread-onlycurrentBroadcast Counter Error :This OID when set indicates the Broadcast counter value is invalid on clinet port
1.3.6.1.4.1.20044.32.11.2.4.40.1.4Columnpm1004vMonupRmonBroadcastCntOverloadPortnread-onlycurrentBroadcast Counter Overload :This OID when set indicates a Broadcast counter overload on client port
1.3.6.1.4.1.20044.32.11.2.4.48Tablepm1004vMonupRmonMulticastCntTablenot-accessiblecurrentList of pm1004vMonupRmonMulticastCnt Article
1.3.6.1.4.1.20044.32.11.2.4.48.1Rowpm1004vMonupRmonMulticastCntEntrynot-accessiblecurrentRow definition for the pm1004vMonupRmonMulticastCnt table
1.3.6.1.4.1.20044.32.11.2.4.48.1.1Columnpm1004vMonupRmonMulticastCntIndexread-onlycurrentIndex definition for the pm1004vMonupRmonMulticastCnt table
1.3.6.1.4.1.20044.32.11.2.4.48.1.2Columnpm1004vMonupRmonMulticastCntValuePortnread-onlycurrentClient Input Multicast Packets :This counter is increased each time a Multicast packet is received on the client port <Help> This counter gives the number of M…
1.3.6.1.4.1.20044.32.11.2.4.48.1.3Columnpm1004vMonupRmonMulticastCntErrorPortnread-onlycurrentMulticast Counter Error :This OID when set indicates the Multicast counter value is invalid on clinet port
1.3.6.1.4.1.20044.32.11.2.4.48.1.4Columnpm1004vMonupRmonMulticastCntOverloadPortnread-onlycurrentMulticast Counter Overload :This OID when set indicates a Multicast counter overload on client port
1.3.6.1.4.1.20044.32.11.2.4.208Tablepm1004vMonupLineRmonByteCntTablenot-accessiblecurrentList of pm1004vMonupLineRmonByteCnt Article
1.3.6.1.4.1.20044.32.11.2.4.208.1Rowpm1004vMonupLineRmonByteCntEntrynot-accessiblecurrentRow definition for the pm1004vMonupLineRmonByteCnt table
1.3.6.1.4.1.20044.32.11.2.4.208.1.1Columnpm1004vMonupLineRmonByteCntIndexread-onlycurrentIndex definition for the pm1004vMonupLineRmonByteCnt table
1.3.6.1.4.1.20044.32.11.2.4.208.1.2Columnpm1004vMonupLineRmonByteCntValuePortnread-onlycurrentLine Input Bytes :This counter is increased each time a data byte is received on the Line port <Help> This counter gives the number of bytes received on the Li…
1.3.6.1.4.1.20044.32.11.2.4.208.1.3Columnpm1004vMonupLineRmonByteCntErrorPortnread-onlycurrentBytes Counter Error :This OID when set indicates the Bytes counter value is invalid on line port
1.3.6.1.4.1.20044.32.11.2.4.208.1.4Columnpm1004vMonupLineRmonByteCntOverloadPortnread-onlycurrentBytes Counter Overload :This OID when set indicates a Bytes counter overload on line port
1.3.6.1.4.1.20044.32.11.2.4.209Tablepm1004vMonupLineRmonCrcErrorCntTablenot-accessiblecurrentList of pm1004vMonupLineRmonCrcErrorCnt Article
1.3.6.1.4.1.20044.32.11.2.4.209.1Rowpm1004vMonupLineRmonCrcErrorCntEntrynot-accessiblecurrentRow definition for the pm1004vMonupLineRmonCrcErrorCnt table
1.3.6.1.4.1.20044.32.11.2.4.209.1.1Columnpm1004vMonupLineRmonCrcErrorCntIndexread-onlycurrentIndex definition for the pm1004vMonupLineRmonCrcErrorCnt table
1.3.6.1.4.1.20044.32.11.2.4.209.1.2Columnpm1004vMonupLineRmonCrcErrorCntValuePortnread-onlycurrentLine Input CRC Errors :This counter is increased each time a CRC error is detected on the Line port <Help> This counter gives the number of CRC Errors received…
1.3.6.1.4.1.20044.32.11.2.4.209.1.3Columnpm1004vMonupLineRmonCrcErrorCntErrorPortnread-onlycurrentCRC Errors Counter Error :This OID when set indicates the CRC Errors counter value is invalid on line port
1.3.6.1.4.1.20044.32.11.2.4.209.1.4Columnpm1004vMonupLineRmonCrcErrorCntOverloadPortnread-onlycurrentCRC Errors Counter Overload :This OID when set indicates a CRC Errors counter overload on line port
1.3.6.1.4.1.20044.32.11.2.4.210Tablepm1004vMonupLineRmonPacketsCntTablenot-accessiblecurrentList of pm1004vMonupLineRmonPacketsCnt Article
1.3.6.1.4.1.20044.32.11.2.4.210.1Rowpm1004vMonupLineRmonPacketsCntEntrynot-accessiblecurrentRow definition for the pm1004vMonupLineRmonPacketsCnt table
1.3.6.1.4.1.20044.32.11.2.4.210.1.1Columnpm1004vMonupLineRmonPacketsCntIndexread-onlycurrentIndex definition for the pm1004vMonupLineRmonPacketsCnt table
1.3.6.1.4.1.20044.32.11.2.4.210.1.2Columnpm1004vMonupLineRmonPacketsCntValuePortnread-onlycurrentLine Input Packets :This counter is increased each time a packet is received on the Line port <Help> This counter gives the number of packets received on the L…
1.3.6.1.4.1.20044.32.11.2.4.210.1.3Columnpm1004vMonupLineRmonPacketsCntErrorPortnread-onlycurrentPackets Counter Error :This OID when set indicates the Packets counter value is invalid on client port
1.3.6.1.4.1.20044.32.11.2.4.210.1.4Columnpm1004vMonupLineRmonPacketsCntOverloadPortnread-onlycurrentPackets Counter Overload :This OID when set indicates a Packets counter overload on line port
1.3.6.1.4.1.20044.32.11.3Nodepm1004vMonLine
1.3.6.1.4.1.20044.32.11.3.4Nodepm1004vMonLineRmonCounter
Type Definitions
NameSyntaxStatusDescription
Pm1004vAdjustValueINTEGER { otxadjustvalue0(0), otxadjustvalue1(1), otxadjustvalue2(2), otxadjustvalue3(3), otxadjustvalue4(4), otxadjustvalue5(5), otxadjustvalue6(6), otxadjustvalue7(7), otxadjustvalue8(8), otxadjustvalue9(9), otxadjustvalue10(10) }currentDifferent values in Adjust mode on OTX-TLH on client and line ports
Pm1004vClientOosModeINTEGER { clientportis(0), clienttxoos(1), clientrxoos(2), clientportoos(3) }currentMode for OOS on client ports
Pm1004vDccModeINTEGER { dccNo(0), dcctermLine1(1), dcctermLine2(2), dcctermLines12(3), dccmaster(4), dccslaveLine12(7) }currentMode for DCC
Pm1004vModeAddDropINTEGER { singleSplitSelect(256) }currentdifferent mode for client
Pm1004vModeTimeSlotINTEGER { singleSplitSelect(256) }currentdifferent mode for time slot
Pm1004vOtxChannelINTEGERcurrentChannel selection on OTX-TLH on client and line ports
Pm1004vOtxGridINTEGER { otxgrid200(200), otxgrid100(100), otxgrid50(50) }currentDifferent grids on OTX-TLH on client and line ports
Pm1004vOtxModeINTEGER { otx80mode(1), otx60mode(2), otxadjustmode(4) }currentDifferent modes on OTX-TLH on client and line ports
Pm1004vProtectionStartUpINTEGER { auto(2), manualX2Line2(0), manualX1Line1(1) }currentprotection for startup
Pm1004vProtectionTimeSlotINTEGER { auto(0), manualX2Line2(257), manualX1Line1(513) }currentprotection for control