EKINOPS-Pm1004V-MIB
611 objects
MIB for managing Ekinops modules with PM1004V software
Imported Objects
| EKINOPS-MIB | EkiApiState EkiMeasureType EkiMode ekinops EkiOnOff EkiProtocol EkiState EkiSynchroMode |
| SNMPv2-SMI | Counter32 Integer32 IpAddress MODULE-IDENTITY NOTIFICATION-TYPE OBJECT-TYPE Unsigned32 |
| SNMPv2-TC | DisplayString TEXTUAL-CONVENTION |
| OID | Name | Access | Status | Description |
|---|---|---|---|---|
| 1.3.6.1.4.1.20044.32 | IdentitymodulePm1004v | MIB for managing Ekinops modules with PM1004V software | ||
| 1.3.6.1.4.1.20044.32.2 | Nodepm1004valarms | |||
| 1.3.6.1.4.1.20044.32.2.1 | Nodepm1004vAlmOther | |||
| 1.3.6.1.4.1.20044.32.2.1.1 | Nodepm1004vAlmOtherNurg | |||
| 1.3.6.1.4.1.20044.32.2.1.1.2 | Nodepm1004vAlmsynthAlm2 | |||
| 1.3.6.1.4.1.20044.32.2.1.1.2.1 | Scalarpm1004vAlmConfTableSave | read-only | current | PM Configuration Save :This OID is at 1 during the saving of a new configuration table in the module Flash memory. <Condtype> CONF_TABLE_SAVE <Probcause> other… |
| 1.3.6.1.4.1.20044.32.2.1.1.2.2 | Scalarpm1004vAlmInvUpload | read-only | current | Inventory Upload :This OID is at 1 during the uploading of PM inventory information. <Condtype> INV_UPLOAD <Probcause> other (1) <Alarmtype> other (1) <Polarit… |
| 1.3.6.1.4.1.20044.32.2.1.1.2.3 | Scalarpm1004vAlmConfTableLoad | read-only | current | PM Configuration Load :This OID is at 1 during the loading of configuration tables in the modules RAM. <Condtype> CONF_TABLE_LOAD <Probcause> other (1) <Alarmt… |
| 1.3.6.1.4.1.20044.32.2.1.1.2.4 | Scalarpm1004vAlmCorrelatOff | read-only | current | Not Used :This OID, when set, indicates that alarm correlation is not being performed. <Condtype> CORRELAT_OFF <Probcause> other (1) <Alarmtype> other (1) <Pol… |
| 1.3.6.1.4.1.20044.32.2.1.1.2.5 | Scalarpm1004vAlmMaintenanceOn | read-only | current | Maintenance Mode :This OID indicates that the PM is in maintenance mode. <Help> This alarm indicates that the maintenance mode is enabled on the PM <Condtype> … |
| 1.3.6.1.4.1.20044.32.2.1.2 | Nodepm1004vAlmOtherUrg | |||
| 1.3.6.1.4.1.20044.32.2.1.2.194 | Nodepm1004vAlmmodInitFailLevel2 | |||
| 1.3.6.1.4.1.20044.32.2.1.2.194.1 | Scalarpm1004vAlmLedFail | read-only | current | Led Fail :This OID indicates that Led register has not been correctly initalized <Help> This alarm indicates if the module LEDs are correctly initialized <Cond… |
| 1.3.6.1.4.1.20044.32.2.1.2.194.2 | Scalarpm1004vAlmNextColdBootForced | read-only | current | Next Cold Boot Forced :This OID indicates that the next Reset will be forced Cold <Help> This alarm indicates that the next reset of the module will be forced … |
| 1.3.6.1.4.1.20044.32.2.1.2.194.3 | Scalarpm1004vAlmBootUndone | read-only | current | Boot Undone :This OID indicates that the boot has not been correctly achieved <Help> This alarm indicates if the module has correctly boot <Condtype> BOOT_UNDO… |
| 1.3.6.1.4.1.20044.32.2.1.2.194.4 | Scalarpm1004vAlmResetHwInitFail | read-only | current | Reset HW Init Fail :This OID indicates that the HW intialization has caused unknown intial conditions <Help> This alarm indicates if the HW has been correctly … |
| 1.3.6.1.4.1.20044.32.2.1.2.194.5 | Scalarpm1004vAlmSwInitFail | read-only | current | SW Init Fail :This OID indicates that the SW intialization has caused unknown intial conditions <Help> This alarm indicates if the SW module is correctly initi… |
| 1.3.6.1.4.1.20044.32.2.1.2.195 | Nodepm1004vAlmmodInitFailLevel3 | |||
| 1.3.6.1.4.1.20044.32.2.1.2.195.1 | Scalarpm1004vAlmGwIdentFail | read-only | current | GW Ident Fail :This OID indicates that GW identification has not been read <Help> This alarm indicates if the GW has been correctly identified <Condtype> GW_ID… |
| 1.3.6.1.4.1.20044.32.2.1.2.195.2 | Scalarpm1004vAlmObmTypeReadFail | read-only | current | OBM Type Read Fail :This OID indicates that OBM type has not been recognized <Help> This alarm indicates if the OBM board has been correctly identified <Condty… |
| 1.3.6.1.4.1.20044.32.2.1.2.195.3 | Scalarpm1004vAlmInitModuleFail | read-only | current | Init Module Fail :This OID indicates that the Module has not been correctly initialized <Help> This alarm indicates if the SW module is correctly initialized <… |
| 1.3.6.1.4.1.20044.32.2.1.2.195.5 | Scalarpm1004vAlmXfp1InitFail | read-only | current | XFP1 Init Fail :This OID indicates that the XFP has not been correctly initialized <Help> This alarm indicates if the line transceiver 1 is correctly initializ… |
| 1.3.6.1.4.1.20044.32.2.1.2.195.6 | Scalarpm1004vAlmXfp2InitFail | read-only | current | XFP2 Init Fail :This OID indicates that the XFP has not been correctly initialized <Help> This alarm indicates if the line transceiver 2 is correctly initializ… |
| 1.3.6.1.4.1.20044.32.2.1.2.195.7 | Scalarpm1004vAlmLine1InitFail | read-only | current | Line1 Init Fail :This OID indicates that the Line registersvsubset has not been correctly initialized <Help> This alarm indicates if the line port 1 is correct… |
| 1.3.6.1.4.1.20044.32.2.1.2.195.8 | Scalarpm1004vAlmLine2InitFail | read-only | current | Line2 Init Fail :This OID indicates that the Line register subset has not been correctly initialized <Help> This alarm indicates if the line port 2 is correctl… |
| 1.3.6.1.4.1.20044.32.2.1.2.195.9 | Scalarpm1004vAlmClient1InitFail | read-only | current | Client1 Init Fail :This OID indicates that Client 1 registers subset has not been correctly initialized <Help> This alarm indicates if the client port 1 is cor… |
| 1.3.6.1.4.1.20044.32.2.1.2.195.10 | Scalarpm1004vAlmClient2InitFail | read-only | current | Client2 Init Fail :This OID indicates that Client 2 registers subset has not been correctly initialized <Help> This alarm indicates if the client port 2 is cor… |
| 1.3.6.1.4.1.20044.32.2.1.2.195.11 | Scalarpm1004vAlmClient3InitFail | read-only | current | Client3 Init Fail :This OID indicates that Client 3 registers subset has not been correctly initialized <Help> This alarm indicates if the client port 3 is cor… |
| 1.3.6.1.4.1.20044.32.2.1.2.195.12 | Scalarpm1004vAlmClient4InitFail | read-only | current | Client4 Init Fail :This OID indicates that Client 4 registers subset has not been correctly initialized <Help> This alarm indicates if the client port 4 is cor… |
| 1.3.6.1.4.1.20044.32.2.1.2.195.13 | Scalarpm1004vAlmClient5InitFail | read-only | current | Client5 Init Fail :This OID indicates that Client 5 registers subset has not been correctly initialized <Help> This alarm indicates if the client port 5 is cor… |
| 1.3.6.1.4.1.20044.32.2.1.2.195.14 | Scalarpm1004vAlmClient6InitFail | read-only | current | Client6 Init Fail :This OID indicates that Client 6 registers subset has not been correctly initialized <Help> This alarm indicates if the client port 6 is cor… |
| 1.3.6.1.4.1.20044.32.2.1.2.198 | Nodepm1004vAlmclientRxProt | |||
| 1.3.6.1.4.1.20044.32.2.1.2.198.1 | Scalarpm1004vAlmAdddropClient1West | read-only | current | Client West Rx Side Active :This OID indicates the Client is active on West receiving side <Condtype> ADDDROP_CLIENT1_WEST <Probcause> other (1) <Alarmtype> ot… |
| 1.3.6.1.4.1.20044.32.2.1.2.198.2 | Scalarpm1004vAlmAdddropClient2West | read-only | current | Client West Rx Side Active :This OID indicates the Client is active on West receiving side <Condtype> ADDDROP_CLIENT2_WEST <Probcause> other (1) <Alarmtype> ot… |
| 1.3.6.1.4.1.20044.32.2.1.2.198.3 | Scalarpm1004vAlmAdddropClient3West | read-only | current | Client West Rx Side Active :This OID indicates the Client is active on West receiving side <Condtype> ADDDROP_CLIENT3_WEST <Probcause> other (1) <Alarmtype> ot… |
| 1.3.6.1.4.1.20044.32.2.1.2.198.4 | Scalarpm1004vAlmAdddropClient4West | read-only | current | Client West Rx Side Active :This OID indicates the Client is active on West receiving side <Condtype> ADDDROP_CLIENT4_WEST <Probcause> other (1) <Alarmtype> ot… |
| 1.3.6.1.4.1.20044.32.2.1.2.198.5 | Scalarpm1004vAlmAdddropClient5West | read-only | current | Client West Rx Side Active :This OID indicates the Client is active on West receiving side <Condtype> ADDDROP_CLIENT5_WEST <Probcause> other (1) <Alarmtype> ot… |
| 1.3.6.1.4.1.20044.32.2.1.2.198.6 | Scalarpm1004vAlmAdddropClient6West | read-only | current | Client West Rx Side Active :This OID indicates the Client is active on West receiving side <Condtype> ADDDROP_CLIENT6_WEST <Probcause> other (1) <Alarmtype> ot… |
| 1.3.6.1.4.1.20044.32.2.1.2.198.9 | Scalarpm1004vAlmAdddropClient1East | read-only | current | Client East Rx Side Active :This OID indicates the Client is active on East receiving side <Condtype> ADDDROP_CLIENT1_EAST <Probcause> other (1) <Alarmtype> ot… |
| 1.3.6.1.4.1.20044.32.2.1.2.198.10 | Scalarpm1004vAlmAdddropClient2East | read-only | current | Client East Rx Side Active :This OID indicates the Client is active on East receiving side <Condtype> ADDDROP_CLIENT2_EAST <Probcause> other (1) <Alarmtype> ot… |
| 1.3.6.1.4.1.20044.32.2.1.2.198.11 | Scalarpm1004vAlmAdddropClient3East | read-only | current | Client East Rx Side Active :This OID indicates the Client is active on East receiving side <Condtype> ADDDROP_CLIENT3_EAST <Probcause> other (1) <Alarmtype> ot… |
| 1.3.6.1.4.1.20044.32.2.1.2.198.12 | Scalarpm1004vAlmAdddropClient4East | read-only | current | Client East Rx Side Active :This OID indicates the Client is active on East receiving side <Condtype> ADDDROP_CLIENT4_EAST <Probcause> other (1) <Alarmtype> ot… |
| 1.3.6.1.4.1.20044.32.2.1.2.198.13 | Scalarpm1004vAlmAdddropClient5East | read-only | current | Client East Rx Side Active :This OID indicates the Client is active on East receiving side <Condtype> ADDDROP_CLIENT5_EAST <Probcause> other (1) <Alarmtype> ot… |
| 1.3.6.1.4.1.20044.32.2.1.2.198.14 | Scalarpm1004vAlmAdddropClient6East | read-only | current | Client East Rx Side Active :This OID indicates the Client is active on East receiving side <Condtype> ADDDROP_CLIENT6_EAST <Probcause> other (1) <Alarmtype> ot… |
| 1.3.6.1.4.1.20044.32.2.1.3 | Nodepm1004vAlmOtherCrit | |||
| 1.3.6.1.4.1.20044.32.2.1.3.0 | Nodepm1004vAlmsynthAlm0 | |||
| 1.3.6.1.4.1.20044.32.2.1.3.0.9 | Scalarpm1004vAlmModGlobFail | read-only | current | Module Failure :This OID is set on detection of a failure originating from the PM <Condtype> MOD_GLOB_FAIL <Probcause> equipmentMalfunction (16) <Alarmtype> sy… |
| 1.3.6.1.4.1.20044.32.2.1.3.0.15 | Scalarpm1004vAlmDefFuseA | read-only | current | Fuse A Fail :This OID indicates that the fuse of the power input A is in fail condition <Help> Status of the Fuse A <Condtype> DEF_FUSE_A <Probcause> powerProb… |
| 1.3.6.1.4.1.20044.32.2.1.3.0.16 | Scalarpm1004vAlmDefFuseB | read-only | current | Fuse B Fail :This OID indicates that the fuse of the power input B is in fail condition <Help> Status of the Fuse B <Condtype> DEF_FUSE_B <Probcause> powerProb… |
| 1.3.6.1.4.1.20044.32.2.2 | Nodepm1004vAlmClient | |||
| 1.3.6.1.4.1.20044.32.2.2.1 | Nodepm1004vAlmClientNurg | |||
| 1.3.6.1.4.1.20044.32.2.2.1.48 | Tablepm1004vAlmsfpWarnDdmTable | not-accessible | current | List of pm1004vAlmsfpWarnDdm Article |
| 1.3.6.1.4.1.20044.32.2.2.1.48.1 | Rowpm1004vAlmsfpWarnDdmEntry | not-accessible | current | Row definition for the pm1004vAlmsfpWarnDdm table |
| 1.3.6.1.4.1.20044.32.2.2.1.48.1.1 | Columnpm1004vAlmsfpWarnDdmIndex | read-only | current | Index definition for the pm1004vAlmsfpWarnDdm table |
| 1.3.6.1.4.1.20044.32.2.2.1.48.1.2 | Columnpm1004vAlmTxPwLowWngPortn | read-only | current | Client SFP Tx Power Low Warning :Warning indicating that the SFP output power of port is lower than the threshold value written in the SFP EEPROM <Condtype> TX… |
| 1.3.6.1.4.1.20044.32.2.2.1.48.1.3 | Columnpm1004vAlmTxPwrHighWngPortn | read-only | current | Client SFP Tx Power High Warning :Warning indicating that the SFP output power of port is higher than the threshold value written in the SFP EEPROM <Condtype> … |
| 1.3.6.1.4.1.20044.32.2.2.1.48.1.4 | Columnpm1004vAlmTxBiasLowWngPortn | read-only | current | Client SFP Bias Low Warning :Warning indicating that the SFP laser bias current of port is lower than the threshold value written in the SFP EEPROM <Condtype> … |
| 1.3.6.1.4.1.20044.32.2.2.1.48.1.5 | Columnpm1004vAlmTxBiasHighWngPortn | read-only | current | Client SFP Bias High Warning :Warning indicating that the SFP laser bias current of port is higher than the threshold value written in the SFP EEPROM <Condtype… |
| 1.3.6.1.4.1.20044.32.2.2.1.48.1.6 | Columnpm1004vAlmVccLowWngPortn | read-only | current | Client SFP Power Supply Low Warning :Warning indicating that the SFP power supply of port is lower than the threshold value written in the SFP EEPROM <Condtype… |
| 1.3.6.1.4.1.20044.32.2.2.1.48.1.7 | Columnpm1004vAlmVccHighWngPortn | read-only | current | Client SFP Power Supply High Warning :Warning indicating that the SFP power supply of port is higher than the threshold value written in the SFP EEPROM <Condty… |
| 1.3.6.1.4.1.20044.32.2.2.1.48.1.8 | Columnpm1004vAlmTempLowWngPortn | read-only | current | Client SFP Temp Low Warning :Warning indicating that the SFP temperature of port is lower than the threshold value written in the SFP EEPROM <Condtype> TEMP_LO… |
| 1.3.6.1.4.1.20044.32.2.2.1.48.1.9 | Columnpm1004vAlmTempHighWngPortn | read-only | current | Client SFP Temp High Warning :Warning indicating that the SFP temperature of port is higher than the threshold value written in the SFP EEPROM <Condtype> TEMP_… |
| 1.3.6.1.4.1.20044.32.2.2.1.48.1.16 | Columnpm1004vAlmRxPwrLowWngPortn | read-only | current | Client SFP Rx Power Low Warning :Warning indicating that the SFP input power of port is lower than the threshold value written in the SFP EEPROM <Condtype> RX_… |
| 1.3.6.1.4.1.20044.32.2.2.1.48.1.17 | Columnpm1004vAlmRxPwrHighWngPortn | read-only | current | Client SFP Rx Power High Warning :Warning indicating that the SFP input power of port is higher than the threshold value written in the SFP EEPROM <Condtype> R… |
| 1.3.6.1.4.1.20044.32.2.2.1.56 | Tablepm1004vAlmsfpCritDdmTable | not-accessible | current | List of pm1004vAlmsfpCritDdm Article |
| 1.3.6.1.4.1.20044.32.2.2.1.56.1 | Rowpm1004vAlmsfpCritDdmEntry | not-accessible | current | Row definition for the pm1004vAlmsfpCritDdm table |
| 1.3.6.1.4.1.20044.32.2.2.1.56.1.1 | Columnpm1004vAlmsfpCritDdmIndex | read-only | current | Index definition for the pm1004vAlmsfpCritDdm table |
| 1.3.6.1.4.1.20044.32.2.2.1.56.1.2 | Columnpm1004vAlmTxPwrLowCritPortn | read-only | current | Client SFP Custom Tx Power Low :Custom Alarm indicating that the SFP output power of port is lower than the custom threshold defined in configuration <Help> Cu… |
| 1.3.6.1.4.1.20044.32.2.2.1.56.1.3 | Columnpm1004vAlmTxPwrHighCritPortn | read-only | current | Client SFP Custom Tx Power High :Custom Alarm indicating that the SFP output power of port is higher than the custom threshold defined in configuration <Help> … |
| 1.3.6.1.4.1.20044.32.2.2.1.56.1.16 | Columnpm1004vAlmRxPwrLowCritPortn | read-only | current | Client SFP Custom Rx Power Low :Custom Alarm indicating that the SFP input power of port is lower than the custom threshold defined in configuration <Help> Cus… |
| 1.3.6.1.4.1.20044.32.2.2.1.56.1.17 | Columnpm1004vAlmRxPwrHighCritPortn | read-only | current | Client SFP Custom Rx Power High :Custom Alarm indicating that the SFP input power of port is higher than the custom threshold defined in configuration <Help> C… |
| 1.3.6.1.4.1.20044.32.2.2.2 | Nodepm1004vAlmClientUrg | |||
| 1.3.6.1.4.1.20044.32.2.2.2.32 | Tablepm1004vAlmsfpAlmDdmTable | not-accessible | current | List of pm1004vAlmsfpAlmDdm Article |
| 1.3.6.1.4.1.20044.32.2.2.2.32.1 | Rowpm1004vAlmsfpAlmDdmEntry | not-accessible | current | Row definition for the pm1004vAlmsfpAlmDdm table |
| 1.3.6.1.4.1.20044.32.2.2.2.32.1.1 | Columnpm1004vAlmsfpAlmDdmIndex | read-only | current | Index definition for the pm1004vAlmsfpAlmDdm table |
| 1.3.6.1.4.1.20044.32.2.2.2.32.1.2 | Columnpm1004vAlmTxPwrLowAlaPortn | read-only | current | Client SFP Tx Power Low :Alarm indicating that the SFP output power of port is lower than the threshold value written in the SFP EEPROM <Condtype> TX_PWR_LOW_A… |
| 1.3.6.1.4.1.20044.32.2.2.2.32.1.3 | Columnpm1004vAlmTxPwrHighAlaPortn | read-only | current | Client SFP Tx Power High :Alarm indicating that the SFP output power of port is higher than the threshold value written in the SFP EEPROM <Condtype> TX_PWR_HIG… |
| 1.3.6.1.4.1.20044.32.2.2.2.32.1.4 | Columnpm1004vAlmTxBiasLowAlaPortn | read-only | current | Client SFP Bias Low :Alarm indicating that the SFP laser bias current of port is lower than the threshold value written in the SFP EEPROM <Condtype> TX_BIAS_LO… |
| 1.3.6.1.4.1.20044.32.2.2.2.32.1.5 | Columnpm1004vAlmTxBiasHighAlaPortn | read-only | current | Client SFP Bias High :Alarm indicating that the SFP laser bias current of port is higher than the threshold value written in the SFP EEPROM <Condtype> TX_BIAS_… |
| 1.3.6.1.4.1.20044.32.2.2.2.32.1.6 | Columnpm1004vAlmVccLowAlaPortn | read-only | current | Client SFP Power Supply Low :Alarm indicating that the SFP power supply of port is lower than the threshold value written in the SFP EEPROM <Condtype> VCC_LOW_… |
| 1.3.6.1.4.1.20044.32.2.2.2.32.1.7 | Columnpm1004vAlmVccHighAlaPortn | read-only | current | Client SFP Power Supply High :Alarm indicating that the SFP power supply of port is higher than the threshold value written in the SFP EEPROM <Condtype> VCC_HI… |
| 1.3.6.1.4.1.20044.32.2.2.2.32.1.8 | Columnpm1004vAlmTempLowAlaPortn | read-only | current | Client SFP Temp Low :Alarm indicating that the SFP temperature of port is lower than the threshold value written in the SFP EEPROM <Condtype> TEMP_LOW_ALA_1 <P… |
| 1.3.6.1.4.1.20044.32.2.2.2.32.1.9 | Columnpm1004vAlmTempHighAlaPortn | read-only | current | Client SFP Temp High :Alarm indicating that the SFP temperature of port is higher than the threshold value written in the SFP EEPROM <Condtype> TEMP_HIGH_ALA_1… |
| 1.3.6.1.4.1.20044.32.2.2.2.32.1.16 | Columnpm1004vAlmRxPwrLowAlaPortn | read-only | current | Client SFP Rx Power Low :Alarm indicating that the SFP input power of port is lower than the threshold value written in the SFP EEPROM <Condtype> RX_PWR_LOW_AL… |
| 1.3.6.1.4.1.20044.32.2.2.2.32.1.17 | Columnpm1004vAlmRxPwrHighAlaPortn | read-only | current | Client SFP Rx Power High :Alarm indicating that the SFP input power of port is higher than the threshold value written in the SFP EEPROM <Condtype> RX_PWR_HIGH… |
| 1.3.6.1.4.1.20044.32.2.2.3 | Nodepm1004vAlmClientCrit | |||
| 1.3.6.1.4.1.20044.32.2.2.3.8 | Tablepm1004vAlmsynthAlmPortTable | not-accessible | current | List of pm1004vAlmsynthAlmPort Article |
| 1.3.6.1.4.1.20044.32.2.2.3.8.1 | Rowpm1004vAlmsynthAlmPortEntry | not-accessible | current | Row definition for the pm1004vAlmsynthAlmPort table |
| 1.3.6.1.4.1.20044.32.2.2.3.8.1.1 | Columnpm1004vAlmsynthAlmPortIndex | read-only | current | Index definition for the pm1004vAlmsynthAlmPort table |
| 1.3.6.1.4.1.20044.32.2.2.3.8.1.2 | Columnpm1004vAlmSfpAbsentPortn | read-only | current | Client SFP Absent :This OID indicates that the SFP module is not present in the client port (only significant on Client6-GbE port). <Help> This alarm indicates… |
| 1.3.6.1.4.1.20044.32.2.2.3.8.1.3 | Columnpm1004vAlmDdmAbsentPortn | read-only | current | DDM Supported On Client SFP :This OID indicates that the Client SFP module supports the Digital Diagnostic Monitoring function (only significant on Client6-GbE… |
| 1.3.6.1.4.1.20044.32.2.2.3.8.1.5 | Columnpm1004vAlmHwFailAccPortn | read-only | current | Client HW Fail :This OID indicates a failure on client port, most probably caused by a HW issue. <Condtype> HW_FAIL_ACC_1 <Probcause> equipmentMalfunction (16)… |
| 1.3.6.1.4.1.20044.32.2.2.3.8.1.6 | Columnpm1004vAlmDwLsdPortn | read-only | current | Client Signal Shutdown :This OID indicates the Client SFP transmitter output is ON. <Help> This status indicates if the client transceiver is ON or OFF <Condty… |
| 1.3.6.1.4.1.20044.32.2.2.3.8.1.7 | Columnpm1004vAlmClientLocalOosTxPortn | read-only | current | Tx Client Port In Service :This OID indicates that the local Tx Client port is In Service (1) or Out of Service (2) <Help> This status indicates if the local T… |
| 1.3.6.1.4.1.20044.32.2.2.3.8.1.8 | Columnpm1004vAlmClientLocalOosRxPortn | read-only | current | Rx Client Port In Service :This OID indicates that the local Rx Client port is In Service (1) or Out of Service (2) <Help> This status indicates if the local R… |
| 1.3.6.1.4.1.20044.32.2.2.3.8.1.9 | Columnpm1004vAlmDwCaisPortn | read-only | current | Client AIS Inserted :This OID indicates a CAIS has been inserted on the output client port. <Help> This status indictaes if a Client Alarm Indication Signal is… |
| 1.3.6.1.4.1.20044.32.2.2.3.8.1.10 | Columnpm1004vAlmSfpDdmWarningPortn | read-only | current | Warning On Client SFP DDM :This OID indicates a warning is being received from the Client SFP DDM (only significant on Client6-GbE port) <Help> This alarm indi… |
| 1.3.6.1.4.1.20044.32.2.2.3.8.1.11 | Columnpm1004vAlmSfpDdmAlmPortn | read-only | current | Alarm On Client SFP DDM :This OID indicates an alarm is being received from the Client SFP DDM (only significant on Client6-GbE port) <Help> This alarm indicat… |
| 1.3.6.1.4.1.20044.32.2.2.3.8.1.12 | Columnpm1004vAlmSfpDdmCritPortn | read-only | current | Custom Alarm On Client SFP DDM :This OID indicates a Custom alarm is being received from the Client SFP DDM <Help> This alarm indicates if a DDM Custom Alarm h… |
| 1.3.6.1.4.1.20044.32.2.2.3.8.1.13 | Columnpm1004vAlmFailAccPortn | read-only | current | Client Access Fail :This OID indicates a failure on the Client port <Condtype> FAIL_ACC_1 <Probcause> equipmentMalfunction (16) <Alarmtype> synthesisAlarm (12)… |
| 1.3.6.1.4.1.20044.32.2.2.3.8.1.16 | Columnpm1004vAlmClientActivePortn | read-only | current | Client Sink (Line1 Or Line2) :This bit indicates the Client #n is active on receive side <Help> This status indicates whether the Client is extracted from Line… |
| 1.3.6.1.4.1.20044.32.2.2.3.8.1.17 | Columnpm1004vAlmUpCsfPortn | read-only | current | Client Signal Fail Inserted :This OID indicates a CSF has been inserted in the upstream client port. <Help> This status indicates if a Client Signal Fail is cu… |
| 1.3.6.1.4.1.20044.32.2.2.3.16 | Tablepm1004vAlmaccessioAlmTable | not-accessible | current | List of pm1004vAlmaccessioAlm Article |
| 1.3.6.1.4.1.20044.32.2.2.3.16.1 | Rowpm1004vAlmaccessioAlmEntry | not-accessible | current | Row definition for the pm1004vAlmaccessioAlm table |
| 1.3.6.1.4.1.20044.32.2.2.3.16.1.1 | Columnpm1004vAlmaccessioAlmIndex | read-only | current | Index definition for the pm1004vAlmaccessioAlm table |
| 1.3.6.1.4.1.20044.32.2.2.3.16.1.2 | Columnpm1004vAlmDwLasFailPortn | read-only | current | Client SFP Tx Failed :This OID indicates that the transmitter fails for the SFP plugged into the client port. This alarm reports the transmitter failure alarm … |
| 1.3.6.1.4.1.20044.32.2.2.3.16.1.5 | Columnpm1004vAlmUpLosPortn | read-only | current | Client Input Loss Of Signal :This OID indicates that no signal is present on the client port <Help> This alarm indicates if a signal is detected on the client … |
| 1.3.6.1.4.1.20044.32.2.2.3.72 | Tablepm1004vAlmmapperDeAlmTable | not-accessible | current | List of pm1004vAlmmapperDeAlm Article |
| 1.3.6.1.4.1.20044.32.2.2.3.72.1 | Rowpm1004vAlmmapperDeAlmEntry | not-accessible | current | Row definition for the pm1004vAlmmapperDeAlm table |
| 1.3.6.1.4.1.20044.32.2.2.3.72.1.1 | Columnpm1004vAlmmapperDeAlmIndex | read-only | current | Index definition for the pm1004vAlmmapperDeAlm table |
| 1.3.6.1.4.1.20044.32.2.2.3.72.1.2 | Columnpm1004vAlmUpAccOosPortn | read-only | current | Client Loss Of Synchro :This OID indicates the upstream client input port has lost synchronization on its decoder <Help> This alarms indicates if the input cli… |
| 1.3.6.1.4.1.20044.32.2.2.3.72.1.11 | Columnpm1004vAlmUpBufferOvlPortn | read-only | current | Client Upstream Buffer Overload :This OID indicates that the rate adaptation buffer for client port is in overload. <Help> This alarm indicates if there is a u… |
| 1.3.6.1.4.1.20044.32.2.2.3.72.1.12 | Columnpm1004vAlmDwCsfDetPortn | read-only | current | Client Signal Fail Detected :This OID indicates that a CSF has been detected on client port in the downstream direction <Help> This alarm indicates if a Client… |
| 1.3.6.1.4.1.20044.32.2.2.3.72.1.15 | Columnpm1004vAlmDwBufferOvlPortn | read-only | current | Client Downstream Buffer Overload :This OID indicates that the de-mapper buffer for client port is in overload. <Help> This alarm indicates if there is a downs… |
| 1.3.6.1.4.1.20044.32.2.2.3.112 | Tablepm1004vAlmvideoProtocolStatusTable | not-accessible | current | List of pm1004vAlmvideoProtocolStatus Article |
| 1.3.6.1.4.1.20044.32.2.2.3.112.1 | Rowpm1004vAlmvideoProtocolStatusEntry | not-accessible | current | Row definition for the pm1004vAlmvideoProtocolStatus table |
| 1.3.6.1.4.1.20044.32.2.2.3.112.1.1 | Columnpm1004vAlmvideoProtocolStatusIndex | read-only | current | Index definition for the pm1004vAlmvideoProtocolStatus table |
| 1.3.6.1.4.1.20044.32.2.2.3.112.1.2 | Columnpm1004vAlmSdiTxPortn | read-only | current | SDI Detected On Tx :This OID indicates that the SDI protocol has been detected on the transmit side of the port (only significant on Video2 to Video 5 ports) <… |
| 1.3.6.1.4.1.20044.32.2.2.3.112.1.3 | Columnpm1004vAlmHdSdiPalTxPortn | read-only | current | HD-SDI-PAL Detected On Tx :This OID indicates that the HD-SDI-PAL protocol has been detected on the transmit side of the port (only significant on Video2 to Vi… |
| 1.3.6.1.4.1.20044.32.2.2.3.112.1.4 | Columnpm1004vAlmHdSdiNtscTxPortn | read-only | current | HD-SDI-NTSC Detected On Tx :This OID indicates that the HD-SDI-NTSC protocol has been detected on the transmit side of the port (only significant on Video2 to … |
| 1.3.6.1.4.1.20044.32.2.2.3.112.1.5 | Columnpm1004vAlmDvbAsiTxPortn | read-only | current | DVB-ASI Detected On Tx :This OID indicates that the DVB-ASI protocol has been detected on the transmit side of the port (only significant on Video2 to Video 5 … |
| 1.3.6.1.4.1.20044.32.2.2.3.112.1.6 | Columnpm1004vAlmFastEtherTxPortn | read-only | current | Fast Ethernet Detected On Tx :This OID indicates that the Fast Ethernet protocol has been detected on the port (only significant on Client1-RJ45 port) <Help> T… |
| 1.3.6.1.4.1.20044.32.2.2.3.112.1.7 | Columnpm1004vAlmGbeTxPortn | read-only | current | Gigabit Ethernet Detected On Tx :This OID indicates that the Gigabit Ethernet protocol has been detected on the port (only significant on Client6-GbE port) <He… |
| 1.3.6.1.4.1.20044.32.2.2.3.112.1.10 | Columnpm1004vAlmSdiRxPortn | read-only | current | SDI Detected On Rx :This OID indicates that the SDI protocol has been detected on the receive side of the port (only significant on Video2 to Video 5 ports) <H… |
| 1.3.6.1.4.1.20044.32.2.2.3.112.1.11 | Columnpm1004vAlmHdSdiPalRxPortn | read-only | current | HD-SDI-PAL Detected On Rx :This OID indicates that the HD-SDI-PAL protocol has been detected on the receive side of the port (only significant on Video2 to Vid… |
| 1.3.6.1.4.1.20044.32.2.2.3.112.1.12 | Columnpm1004vAlmHdSdiNtscRxPortn | read-only | current | HD-SDI-NTSC Detected On Rx :This OID indicates that the HD-SDI-NTSC protocol has been detected on the receive side of the port (only significant on Video2 to V… |
| 1.3.6.1.4.1.20044.32.2.2.3.112.1.13 | Columnpm1004vAlmDvbAsiRxPortn | read-only | current | DVB-ASI Detected On Rx :This OID indicates that the DVB-ASI protocol has been detected on the receive side of the port (only significant on Video2 to Video 5 p… |
| 1.3.6.1.4.1.20044.32.2.2.3.112.1.14 | Columnpm1004vAlmFastEtherRxPortn | read-only | current | Fast Ethernet Detected On Rx :This OID indicates that the Fast Ethernet protocol has been detected on the port (only significant on Client1-RJ45 port) <Help> T… |
| 1.3.6.1.4.1.20044.32.2.2.3.112.1.15 | Columnpm1004vAlmGbeRxPortn | read-only | current | Gigabit Ethernet Detected On Rx :This OID indicates that the Gigabit Ethernet protocol has been detected on the port (only significant on Client6-GbE port) <He… |
| 1.3.6.1.4.1.20044.32.2.3 | Nodepm1004vAlmLine | |||
| 1.3.6.1.4.1.20044.32.2.3.1 | Nodepm1004vAlmLineNurg | |||
| 1.3.6.1.4.1.20044.32.2.3.1.209 | Tablepm1004vAlmlineXfp1WarningsTable | not-accessible | current | List of pm1004vAlmlineXfp1Warnings Article |
| 1.3.6.1.4.1.20044.32.2.3.1.209.1 | Rowpm1004vAlmlineXfp1WarningsEntry | not-accessible | current | Row definition for the pm1004vAlmlineXfp1Warnings table |
| 1.3.6.1.4.1.20044.32.2.3.1.209.1.1 | Columnpm1004vAlmlineXfp1WarningsIndex | read-only | current | Index definition for the pm1004vAlmlineXfp1Warnings table |
| 1.3.6.1.4.1.20044.32.2.3.1.209.1.2 | Columnpm1004vAlmTxPowerLowWarningPortn | read-only | current | Line Optical Tx Power Low Warning :Warning indicating that the XFP/OTX transmitter transmitter output power is lower than the threshold value written in the XF… |
| 1.3.6.1.4.1.20044.32.2.3.1.209.1.3 | Columnpm1004vAlmTxPowerHighWarningPortn | read-only | current | Line Optical Tx Power High Warning :Warning indicating that the XFP/OTX transmitter transmitter output power is higher than the threshold value written in the … |
| 1.3.6.1.4.1.20044.32.2.3.1.209.1.4 | Columnpm1004vAlmTxBiasLowWarningPortn | read-only | current | Line Transceiver Bias Low Warning :Warning indicating that the XFP/OTX transmitter laser bias current is lower than the threshold value written in the XFP/OTX … |
| 1.3.6.1.4.1.20044.32.2.3.1.209.1.5 | Columnpm1004vAlmTxBiasHighWarningPortn | read-only | current | Line Transceiver Bias High Warning :Warning indicating that the XFP/OTX transmitter laser bias current is higher than the threshold value written in the XFP EE… |
| 1.3.6.1.4.1.20044.32.2.3.1.209.1.8 | Columnpm1004vAlmTempLowWarningPortn | read-only | current | Line Transceiver Temp Low Warning :Warning indicating that the XFP/OTX temperature is lower than the threshold value written in the XFP/OTX EEPROM <Condtype> T… |
| 1.3.6.1.4.1.20044.32.2.3.1.209.1.9 | Columnpm1004vAlmTempHighWarningPortn | read-only | current | Line Transceiver Temp High Warning :Warning indicating that the XFP/OTX temperature is higher than the threshold value written in the XFP EEPROM <Condtype> TEM… |
| 1.3.6.1.4.1.20044.32.2.3.1.209.1.16 | Columnpm1004vAlmRxPowerLowWarningPortn | read-only | current | Line Optical Rx Power Low Warning :Warning indicating that the XFP received optical power is lower than the threshold value written in the XFP EEPROM <Condtype… |
| 1.3.6.1.4.1.20044.32.2.3.1.209.1.17 | Columnpm1004vAlmRxPowerHighWarningPortn | read-only | current | Line Optical Rx Power High Warning :Warning indicating that the XFP received optical power is higher than the threshold value written in the XFP EEPROM <Condty… |
| 1.3.6.1.4.1.20044.32.2.3.1.225 | Tablepm1004vAlmlineOtx1TlhWarningsTable | not-accessible | current | List of pm1004vAlmlineOtx1TlhWarnings Article |
| 1.3.6.1.4.1.20044.32.2.3.1.225.1 | Rowpm1004vAlmlineOtx1TlhWarningsEntry | not-accessible | current | Row definition for the pm1004vAlmlineOtx1TlhWarnings table |
| 1.3.6.1.4.1.20044.32.2.3.1.225.1.1 | Columnpm1004vAlmlineOtx1TlhWarningsIndex | read-only | current | Index definition for the pm1004vAlmlineOtx1TlhWarnings table |
| 1.3.6.1.4.1.20044.32.2.3.1.225.1.6 | Columnpm1004vAlmLineModulatorAgingHighWarningPortn | read-only | current | Line Modulator Aging High Warning :Warning indicating the Line OTX TLH modulator aging is higher than the threshold written in the EEPROM <Condtype> LINE_MODUL… |
| 1.3.6.1.4.1.20044.32.2.3.1.225.1.7 | Columnpm1004vAlmLineAgingHighWarningPortn | read-only | current | Line OTX TLH Aging High Warning :Warning indicating the Line OTX TLH aging is higher than the threshold written in the EEPROM <Condtype> LINE_AGING_HIGH_WARNIN… |
| 1.3.6.1.4.1.20044.32.2.3.1.225.1.13 | Columnpm1004vAlmLineFreqDevHighWarningPortn | read-only | current | Line Freq. Deviation High Warning :Warning indicating the Line OTX TLH frequency deviation is higher than the threshold written in the EEPROM <Condtype> LINE_F… |
| 1.3.6.1.4.1.20044.32.2.3.1.225.1.15 | Columnpm1004vAlmLineLaserTempHighWarningPortn | read-only | current | Line Laser Temp. High Warning :Warning indicating the Line OTX TLH laser temperature is higher than the threshold written in the EEPROM <Condtype> LINE_LASER_T… |
| 1.3.6.1.4.1.20044.32.2.3.2 | Nodepm1004vAlmLineUrg | |||
| 1.3.6.1.4.1.20044.32.2.3.2.208 | Tablepm1004vAlmlineXfp1AlarmTable | not-accessible | current | List of pm1004vAlmlineXfp1Alarm Article |
| 1.3.6.1.4.1.20044.32.2.3.2.208.1 | Rowpm1004vAlmlineXfp1AlarmEntry | not-accessible | current | Row definition for the pm1004vAlmlineXfp1Alarm table |
| 1.3.6.1.4.1.20044.32.2.3.2.208.1.1 | Columnpm1004vAlmlineXfp1AlarmIndex | read-only | current | Index definition for the pm1004vAlmlineXfp1Alarm table |
| 1.3.6.1.4.1.20044.32.2.3.2.208.1.2 | Columnpm1004vAlmTxPowerLowAlarmPortn | read-only | current | Line Optical Tx Power Low :Alarm indicating that the XFP/OTX transmitter transmitter output power is lower than the threshold value written in the XFP/OTX EEPR… |
| 1.3.6.1.4.1.20044.32.2.3.2.208.1.3 | Columnpm1004vAlmTxPowerHighAlarmPortn | read-only | current | Line Optical Tx Power High :Alarm indicating that the XFP/OTX transmitter transmitter output power is higher than the threshold value written in the XFP EEPROM… |
| 1.3.6.1.4.1.20044.32.2.3.2.208.1.4 | Columnpm1004vAlmTxBiasLowAlarmPortn | read-only | current | Line Transceiver Bias Low :Alarm indicating that the XFP/OTX transmitter laser bias current is lower than the threshold value written in the XFP/OTX EEPROM <Co… |
| 1.3.6.1.4.1.20044.32.2.3.2.208.1.5 | Columnpm1004vAlmTxBiasHighAlarmPortn | read-only | current | Line Transceiver Bias High :Alarm indicating that the XFP/OTX transmitter laser bias current is higher than the threshold value written in the XFP EEPROM <Cond… |
| 1.3.6.1.4.1.20044.32.2.3.2.208.1.8 | Columnpm1004vAlmTempLowAlarmPortn | read-only | current | Line Transceiver Temp Low :Alarm indicating that the XFP/OTX temperature is lower than the threshold value written in the XFP/OTX EEPROM <Condtype> TEMP_LOW_AL… |
| 1.3.6.1.4.1.20044.32.2.3.2.208.1.9 | Columnpm1004vAlmTempHighAlarmPortn | read-only | current | Line Transceiver Temp High :Alarm indicating that the XFP/OTX temperature is higher than the threshold value written in the XFP EEPROM <Condtype> TEMP_HIGH_ALA… |
| 1.3.6.1.4.1.20044.32.2.3.2.208.1.16 | Columnpm1004vAlmRxPowerLowAlarmPortn | read-only | current | Line Optical Rx Power Low :Alarm indicating that the XFP received optical power is lower than the threshold value written in the XFP EEPROM <Condtype> RX_POWER… |
| 1.3.6.1.4.1.20044.32.2.3.2.208.1.17 | Columnpm1004vAlmRxPowerHighAlarmPortn | read-only | current | Line Optical Rx Power High :Alarm indicating that the XFP received optical power is higher than the threshold value written in the XFP EEPROM <Condtype> RX_POW… |
| 1.3.6.1.4.1.20044.32.2.3.2.210 | Tablepm1004vAlmlineXfp1CritTable | not-accessible | current | List of pm1004vAlmlineXfp1Crit Article |
| 1.3.6.1.4.1.20044.32.2.3.2.210.1 | Rowpm1004vAlmlineXfp1CritEntry | not-accessible | current | Row definition for the pm1004vAlmlineXfp1Crit table |
| 1.3.6.1.4.1.20044.32.2.3.2.210.1.1 | Columnpm1004vAlmlineXfp1CritIndex | read-only | current | Index definition for the pm1004vAlmlineXfp1Crit table |
| 1.3.6.1.4.1.20044.32.2.3.2.210.1.2 | Columnpm1004vAlmTxPowerLowCritPortn | read-only | current | Line Custom Tx Power Low :Custom Alarm indicating that the XFP/OTX output power of port is lower than the custom threshold defined in configuration <Help> Cust… |
| 1.3.6.1.4.1.20044.32.2.3.2.210.1.3 | Columnpm1004vAlmTxPowerHighCritPortn | read-only | current | Line Custom Tx Power High :Custom Alarm indicating that the XFP/OTX output power of port is higher than the custom threshold defined in configuration <Help> Cu… |
| 1.3.6.1.4.1.20044.32.2.3.2.210.1.16 | Columnpm1004vAlmRxPowerLowCritPortn | read-only | current | Line Custom Rx Power Low :Custom Alarm indicating that the XFP/OTX input power of port is lower than the custom threshold defined in configuration <Help> Custo… |
| 1.3.6.1.4.1.20044.32.2.3.2.210.1.17 | Columnpm1004vAlmRxPowerHighCritPortn | read-only | current | Line Custom Rx Power High :Custom Alarm indicating that the XFP/OTX input power of port is higher than the custom threshold defined in configuration <Help> Cus… |
| 1.3.6.1.4.1.20044.32.2.3.2.212 | Tablepm1004vAlmlineXfp1SupplyAlarmTable | not-accessible | current | List of pm1004vAlmlineXfp1SupplyAlarm Article |
| 1.3.6.1.4.1.20044.32.2.3.2.212.1 | Rowpm1004vAlmlineXfp1SupplyAlarmEntry | not-accessible | current | Row definition for the pm1004vAlmlineXfp1SupplyAlarm table |
| 1.3.6.1.4.1.20044.32.2.3.2.212.1.1 | Columnpm1004vAlmlineXfp1SupplyAlarmIndex | read-only | current | Index definition for the pm1004vAlmlineXfp1SupplyAlarm table |
| 1.3.6.1.4.1.20044.32.2.3.2.212.1.2 | Columnpm1004vAlmVee5LowAlarmPortn | read-only | current | VEE5 Power Supply Low :Alarm indicating the XFP/OTX VEE5 power supply is lower than the threshold written in the EEPROM <Condtype> VEE5_LOW_ALARM_1 <Probcause>… |
| 1.3.6.1.4.1.20044.32.2.3.2.212.1.3 | Columnpm1004vAlmVee5HighAlarmPortn | read-only | current | VEE5 Power Supply High :Alarm indicating the XFP/OTX VEE5 power supply is higher than the threshold written in the EEPROM <Condtype> VEE5_HIGH_ALARM_1 <Probcau… |
| 1.3.6.1.4.1.20044.32.2.3.2.212.1.4 | Columnpm1004vAlmVcc2LowAlarmPortn | read-only | current | VCC2 Power Supply Low :Alarm indicating the XFP/OTX VCC2 power supply is lower than the threshold written in the EEPROM <Condtype> VCC2_LOW_ALARM_1 <Probcause>… |
| 1.3.6.1.4.1.20044.32.2.3.2.212.1.5 | Columnpm1004vAlmVcc2HighAlarmPortn | read-only | current | VCC2 Power Supply High :Alarm indicating the XFP/OTX VCC2 power supply is higher than the threshold written in the EEPROM <Condtype> VCC2_HIGH_ALARM_1 <Probcau… |
| 1.3.6.1.4.1.20044.32.2.3.2.212.1.6 | Columnpm1004vAlmVcc3LowAlarmPortn | read-only | current | VCC3 Power Supply Low :Alarm indicating the XFP/OTX VCC3 power supply is lower than the threshold written in the EEPROM <Condtype> VCC3_LOW_ALARM_1 <Probcause>… |
| 1.3.6.1.4.1.20044.32.2.3.2.212.1.7 | Columnpm1004vAlmVcc3HighAlarmPortn | read-only | current | VCC3 Power Supply High :Alarm indicating the XFP/OTX VCC3 power supply is higher than the threshold written in the EEPROM <Condtype> VCC3_HIGH_ALARM_1 <Probcau… |
| 1.3.6.1.4.1.20044.32.2.3.2.212.1.8 | Columnpm1004vAlmVcc5LowAlarmPortn | read-only | current | VCC5 Power Supply Low :Alarm indicating the XFP/OTX VCC5 power supply is lower than the threshold written in the EEPROM <Condtype> VCC5_LOW_ALARM_1 <Probcause>… |
| 1.3.6.1.4.1.20044.32.2.3.2.212.1.9 | Columnpm1004vAlmVcc5HighAlarmPortn | read-only | current | VCC5 Power Supply High :Alarm indicating the XFP/OTX VCC5 power supply is higher than the threshold written in the EEPROM <Condtype> VCC5_HIGH_ALARM_1 <Probcau… |
| 1.3.6.1.4.1.20044.32.2.3.2.212.1.10 | Columnpm1004vAlmVee5LowWarningPortn | read-only | current | VEE5 Power Supply Low Warning :Warning indicating the XFP/OTX VEE5 power supply is lower than the threshold written in the EEPROM <Condtype> VEE5_LOW_WARNING_1… |
| 1.3.6.1.4.1.20044.32.2.3.2.212.1.11 | Columnpm1004vAlmVee5HighWarningPortn | read-only | current | VEE5 Power Supply High Warning :Warning indicating the XFP/OTX VEE5 power supply is higher than the threshold written in the EEPROM <Condtype> VEE5_HIGH_WARNIN… |
| 1.3.6.1.4.1.20044.32.2.3.2.212.1.12 | Columnpm1004vAlmVcc2LowWarningPortn | read-only | current | VCC2 Power Supply Low Warning :Warning indicating the XFP/OTX VCC2 power supply is lower than the threshold written in the EEPROM <Condtype> VCC2_LOW_WARNING_1… |
| 1.3.6.1.4.1.20044.32.2.3.2.212.1.13 | Columnpm1004vAlmVcc2HighWarningPortn | read-only | current | VCC2 Power Supply High Warning :Warning indicating the XFP/OTX VCC2 power supply is higher than the threshold written in the EEPROM <Condtype> VCC2_HIGH_WARNIN… |
| 1.3.6.1.4.1.20044.32.2.3.2.212.1.14 | Columnpm1004vAlmVcc3LowWarningPortn | read-only | current | VCC3 Power Supply Low Warning :Warning indicating the XFP/OTX VCC3 power supply is lower than the threshold written in the EEPROM <Condtype> VCC3_LOW_WARNING_1… |
| 1.3.6.1.4.1.20044.32.2.3.2.212.1.15 | Columnpm1004vAlmVcc3HighWarningPortn | read-only | current | VCC3 Power Supply High Warning :Warning indicating the XFP/OTX VCC3 power supply is higher than the threshold written in the EEPROM <Condtype> VCC3_HIGH_WARNIN… |
| 1.3.6.1.4.1.20044.32.2.3.2.212.1.16 | Columnpm1004vAlmVcc5LowWarningPortn | read-only | current | VCC5 Power Supply Low Warning :Warning indicating the XFP/OTX VCC5 power supply is lower than the threshold written in the EEPROM <Condtype> VCC5_LOW_WARNING_1… |
| 1.3.6.1.4.1.20044.32.2.3.2.212.1.17 | Columnpm1004vAlmVcc5HighWarningPortn | read-only | current | VCC5 Power Supply High Warning :Warning indicating the XFP/OTX VCC5 power supply is higher than the threshold written in the EEPROM <Condtype> VCC5_HIGH_WARNIN… |
| 1.3.6.1.4.1.20044.32.2.3.2.224 | Tablepm1004vAlmlineOtx1TlhAlarmsTable | not-accessible | current | List of pm1004vAlmlineOtx1TlhAlarms Article |
| 1.3.6.1.4.1.20044.32.2.3.2.224.1 | Rowpm1004vAlmlineOtx1TlhAlarmsEntry | not-accessible | current | Row definition for the pm1004vAlmlineOtx1TlhAlarms table |
| 1.3.6.1.4.1.20044.32.2.3.2.224.1.1 | Columnpm1004vAlmlineOtx1TlhAlarmsIndex | read-only | current | Index definition for the pm1004vAlmlineOtx1TlhAlarms table |
| 1.3.6.1.4.1.20044.32.2.3.2.224.1.6 | Columnpm1004vAlmLineModulatorAgingHighAlaPortn | read-only | current | Line Modulator Aging High Alarm :Alarm indicating the Line OTX TLH modulator aging is higher than the threshold written in the EEPROM <Condtype> LINE_MODULATOR… |
| 1.3.6.1.4.1.20044.32.2.3.2.224.1.7 | Columnpm1004vAlmLineAgingHighAlaPortn | read-only | current | Line OTX TLH Aging High Alarm :Alarm indicating the Line OTX TLH aging is higher than the threshold written in the EEPROM <Condtype> LINE_AGING_HIGH_ALA_1 <Pro… |
| 1.3.6.1.4.1.20044.32.2.3.2.224.1.13 | Columnpm1004vAlmLineFreqDevHighAlaPortn | read-only | current | Line Freq. Deviation High Alarm :Alarm indicating the Line OTX TLH frequency deviation is higher than the threshold written in the EEPROM <Condtype> LINE_FREQ_… |
| 1.3.6.1.4.1.20044.32.2.3.2.224.1.15 | Columnpm1004vAlmLineLaserTempHighAlaPortn | read-only | current | Line Laser Temp. High Alarm :Alarm indicating the Line OTX TLH laser temperature is higher than the threshold written in the EEPROM <Condtype> LINE_LASER_TEMP_… |
| 1.3.6.1.4.1.20044.32.2.3.3 | Nodepm1004vAlmLineCrit | |||
| 1.3.6.1.4.1.20044.32.2.3.3.7 | Tablepm1004vAlmsynthAlmLineTable | not-accessible | current | List of pm1004vAlmsynthAlmLine Article |
| 1.3.6.1.4.1.20044.32.2.3.3.7.1 | Rowpm1004vAlmsynthAlmLineEntry | not-accessible | current | Row definition for the pm1004vAlmsynthAlmLine table |
| 1.3.6.1.4.1.20044.32.2.3.3.7.1.1 | Columnpm1004vAlmsynthAlmLineIndex | read-only | current | Index definition for the pm1004vAlmsynthAlmLine table |
| 1.3.6.1.4.1.20044.32.2.3.3.7.1.2 | Columnpm1004vAlmXfpAbsentPortn | read-only | current | Line Optical Module Absent :This OID indicates that the line optical interface (XFP or OTX) is not plugged in. <Help> This alarm indicates if the line transcei… |
| 1.3.6.1.4.1.20044.32.2.3.3.7.1.3 | Columnpm1004vAlmXfpInitNotComplPortn | read-only | current | Line Optical Module Ready :This OID indicates that the optical interface (XFP or OTX) is not operational. <Help> This status indicates if the line transceiver … |
| 1.3.6.1.4.1.20044.32.2.3.3.7.1.5 | Columnpm1004vAlmLineHwFailPortn | read-only | current | Line Port HW Failure :This OID indicates a failure on line port, most probably caused by a HW issue <Condtype> LINE_HW_FAIL <Probcause> equipmentMalfunction (1… |
| 1.3.6.1.4.1.20044.32.2.3.3.7.1.6 | Columnpm1004vAlmXfpTxOffPortn | read-only | current | Line Optical Module Laser Shutdown :This OID indicates the line optical output power is on <Help> This status indicates if the line transceiver laser is ON or … |
| 1.3.6.1.4.1.20044.32.2.3.3.7.1.7 | Columnpm1004vAlmLineLocalOosPortn | read-only | current | Line Port In Service :This OID indicates that the Line port is In Service (1) of Out or Service (2) <Help> This status indicates if the line port is in service… |
| 1.3.6.1.4.1.20044.32.2.3.3.7.1.10 | Columnpm1004vAlmLineDdmWarningPortn | read-only | current | Warning On Line Optical Module DDM :This OID indicates a warning is present coming out of Line optical interface DDM <Help> This alarm indicates if a DDM Warni… |
| 1.3.6.1.4.1.20044.32.2.3.3.7.1.11 | Columnpm1004vAlmLineDdmAlmPortn | read-only | current | Alarm On Line Optical Module DDM :This OID indicates an alarm is present coming out of Line optical interface DDM <Help> This alarm indicates if a DDM Alarm ha… |
| 1.3.6.1.4.1.20044.32.2.3.3.7.1.12 | Columnpm1004vAlmLineDdmCritPortn | read-only | current | Custom Alarm On Line XFP/OTX DDM :This OID indicates a Custom alarm is present coming out of Line optical interface DDM <Help> This alarm indicates if a DDM Cu… |
| 1.3.6.1.4.1.20044.32.2.3.3.7.1.13 | Columnpm1004vAlmLineFailPortn | read-only | current | Line Port Failure :This OID indicates a failure on the line port <Condtype> LINE_FAIL <Probcause> equipmentMalfunction (16) <Alarmtype> synthesisAlarm (12) <Po… |
| 1.3.6.1.4.1.20044.32.2.3.3.7.1.17 | Columnpm1004vAlmLineActivePortn | read-only | current | Line Active :This bit indicates the line #n is active on receive side <Help> This status indicates whether the line is active or standby. <Condtype> LINE_ACTIV… |
| 1.3.6.1.4.1.20044.32.2.3.3.128 | Tablepm1004vAlmdfrmAlmTable | not-accessible | current | List of pm1004vAlmdfrmAlm Article |
| 1.3.6.1.4.1.20044.32.2.3.3.128.1 | Rowpm1004vAlmdfrmAlmEntry | not-accessible | current | Row definition for the pm1004vAlmdfrmAlm table |
| 1.3.6.1.4.1.20044.32.2.3.3.128.1.1 | Columnpm1004vAlmdfrmAlmIndex | read-only | current | Index definition for the pm1004vAlmdfrmAlm table |
| 1.3.6.1.4.1.20044.32.2.3.3.128.1.5 | Columnpm1004vAlmDwLossofsyncPortn | read-only | current | Loss Of Synchronisation :This OID indicates the upstream line input port is in Loss of Synchronization. <Help> This alarms indicates if the input signal is cor… |
| 1.3.6.1.4.1.20044.32.2.3.3.133 | Tablepm1004vAlmlineSyncAlarmsTable | not-accessible | current | List of pm1004vAlmlineSyncAlarms Article |
| 1.3.6.1.4.1.20044.32.2.3.3.133.1 | Rowpm1004vAlmlineSyncAlarmsEntry | not-accessible | current | Row definition for the pm1004vAlmlineSyncAlarms table |
| 1.3.6.1.4.1.20044.32.2.3.3.133.1.1 | Columnpm1004vAlmlineSyncAlarmsIndex | read-only | current | Index definition for the pm1004vAlmlineSyncAlarms table |
| 1.3.6.1.4.1.20044.32.2.3.3.133.1.13 | Columnpm1004vAlmDwLockerrPortn | read-only | current | Downstream Clock Lock Error :This OID indicates that the deserializer input 10 Gb/s clock recovery is not locked. <Condtype> DW_LOCKERR <Probcause> receiveFail… |
| 1.3.6.1.4.1.20044.32.2.3.3.133.1.14 | Columnpm1004vAlmUpLockerrPortn | read-only | current | Upstream Clock Lock Error :This OID indicates that the serializer output 10 Gb/s clock multiplier unit is not locked. <Condtype> UP_LOCKERR <Probcause> receive… |
| 1.3.6.1.4.1.20044.32.2.3.3.133.1.17 | Columnpm1004vAlmDwLosPortn | read-only | current | Line Input Loss Of Signal :This OID indicates a loss of signal on the 10 Gb/s input. <Help> This alarm indicates if an optical signal is detected on the line t… |
| 1.3.6.1.4.1.20044.32.2.3.3.211 | Tablepm1004vAlmlineXfp1AlarmsTable | not-accessible | current | List of pm1004vAlmlineXfp1Alarms Article |
| 1.3.6.1.4.1.20044.32.2.3.3.211.1 | Rowpm1004vAlmlineXfp1AlarmsEntry | not-accessible | current | Row definition for the pm1004vAlmlineXfp1Alarms table |
| 1.3.6.1.4.1.20044.32.2.3.3.211.1.1 | Columnpm1004vAlmlineXfp1AlarmsIndex | read-only | current | Index definition for the pm1004vAlmlineXfp1Alarms table |
| 1.3.6.1.4.1.20044.32.2.3.3.211.1.3 | Columnpm1004vAlmModNrPortn | read-only | current | Line Optical Module Not Ready :This OID indicates that the module is unable to determine correct data. <Help> This alarm indicates if the line transceiver is r… |
| 1.3.6.1.4.1.20044.32.2.3.3.211.1.4 | Columnpm1004vAlmRxCdrNotLockedPortn | read-only | current | Line Optical Rx CDR Unlocked :This OID indicates that a loss of lock on the receiving side CDR has been detected <Help> This alarm indicates if the Rx CDR is l… |
| 1.3.6.1.4.1.20044.32.2.3.3.211.1.6 | Columnpm1004vAlmRxNrPortn | read-only | current | Line Optical Rx Not Ready :This OID indicates that a condition has arisen leading to invalid data on the receiving side. <Help> This alarm indicates if the Rx … |
| 1.3.6.1.4.1.20044.32.2.3.3.211.1.7 | Columnpm1004vAlmTxCdrNotLockedPortn | read-only | current | Line Optical Tx CDR Unlocked :This OID indicates a loss of lock on the transmitting side CDR has been detected. <Help> This alarm indicates if the Tx CDR is lo… |
| 1.3.6.1.4.1.20044.32.2.3.3.211.1.8 | Columnpm1004vAlmTxFaultPortn | read-only | current | Line Optical Tx Failure :This OID indicates a fault condition on the laser detected by the safety syste <Help> This alarm indicates if the laser of the line tr… |
| 1.3.6.1.4.1.20044.32.2.3.3.211.1.9 | Columnpm1004vAlmTxNrPortn | read-only | current | Line Optical Tx Not Ready :This OID indicates a condition has arisen leading to invalid data on the transmitting side <Help> This alarm indicates if the Tx par… |
| 1.3.6.1.4.1.20044.32.2.3.3.211.1.15 | Columnpm1004vAlmWavelengthUnlockedPortn | read-only | current | Line Optical Tx Wavelength Unlocked :This OID indicates that the wavelength error is exceeding the manufacturer tolerance <Help> This alarm indicates if the wa… |
| 1.3.6.1.4.1.20044.32.2.3.3.211.1.16 | Columnpm1004vAlmTecFaultPortn | read-only | current | Line Optical Tx Temp Regul Failed :This OID indicates a failure on the TEC module <Help> This alarm indicates if the TEC of the line transceiver is in fail con… |
| 1.3.6.1.4.1.20044.32.2.3.3.211.1.17 | Columnpm1004vAlmApdSupplyFaultPortn | read-only | current | Line Rx Photodiode Power Failed :This OID indicates a failure on the APD power supply <Help> This alarm indicates if the APD power supply is in fail condition … |
| 1.3.6.1.4.1.20044.32.3 | Nodepm1004vmeasures | |||
| 1.3.6.1.4.1.20044.32.3.1 | Nodepm1004vMesrOther | |||
| 1.3.6.1.4.1.20044.32.3.1.0 | Scalarpm1004vMesrsynth0 | read-only | deprecated | Not Used :This OID gives the unit used on AUX1 measurement of XFP#1 (Unit = ) |
| 1.3.6.1.4.1.20044.32.3.1.1 | Scalarpm1004vMesrsynth1 | read-only | deprecated | Not Used :This OID gives the unit used on AUX2 measurement of XFP#1 (Unit = ) |
| 1.3.6.1.4.1.20044.32.3.2 | Nodepm1004vMesrClient | |||
| 1.3.6.1.4.1.20044.32.3.2.16 | Tablepm1004vMesrtempMeasTable | not-accessible | current | List of pm1004vMesrtempMeas Article |
| 1.3.6.1.4.1.20044.32.3.2.16.1 | Rowpm1004vMesrtempMeasEntry | not-accessible | current | Row definition for the pm1004vMesrtempMeas table |
| 1.3.6.1.4.1.20044.32.3.2.16.1.1 | Columnpm1004vMesrtempMeasIndex | read-only | current | Index definition for the pm1004vMesrtempMeas table |
| 1.3.6.1.4.1.20044.32.3.2.16.1.2 | Columnpm1004vMesrtempMeasPortn | read-only | current | Client SFP Temperature :This OID gives the temperature value of the SFP plugged in port, read from the DDM (Digital Diagnostic Monitoring) (Temperature = AV/25… |
| 1.3.6.1.4.1.20044.32.3.2.24 | Tablepm1004vMesrvoltMeasTable | not-accessible | current | List of pm1004vMesrvoltMeas Article |
| 1.3.6.1.4.1.20044.32.3.2.24.1 | Rowpm1004vMesrvoltMeasEntry | not-accessible | current | Row definition for the pm1004vMesrvoltMeas table |
| 1.3.6.1.4.1.20044.32.3.2.24.1.1 | Columnpm1004vMesrvoltMeasIndex | read-only | current | Index definition for the pm1004vMesrvoltMeas table |
| 1.3.6.1.4.1.20044.32.3.2.24.1.2 | Columnpm1004vMesrvoltMeasPortn | read-only | current | Client SFP Power Supply :This OID gives the 3V3 voltage value of the SFP plugged into port, read from the DDM (Digital Diagnostic Monitoring) (Voltage = AV/100… |
| 1.3.6.1.4.1.20044.32.3.2.32 | Tablepm1004vMesrbiasMeasTable | not-accessible | current | List of pm1004vMesrbiasMeas Article |
| 1.3.6.1.4.1.20044.32.3.2.32.1 | Rowpm1004vMesrbiasMeasEntry | not-accessible | current | Row definition for the pm1004vMesrbiasMeas table |
| 1.3.6.1.4.1.20044.32.3.2.32.1.1 | Columnpm1004vMesrbiasMeasIndex | read-only | current | Index definition for the pm1004vMesrbiasMeas table |
| 1.3.6.1.4.1.20044.32.3.2.32.1.2 | Columnpm1004vMesrbiasMeasPortn | read-only | current | Client SFP Laser Bias :This OID gives the bias value of the SFP plugged into port, read from the DDM (Digital Diagnostic Monitoring) (Bias = AV/500) (Unit = mA… |
| 1.3.6.1.4.1.20044.32.3.2.40 | Tablepm1004vMesrtxpwrMeasTable | not-accessible | current | List of pm1004vMesrtxpwrMeas Article |
| 1.3.6.1.4.1.20044.32.3.2.40.1 | Rowpm1004vMesrtxpwrMeasEntry | not-accessible | current | Row definition for the pm1004vMesrtxpwrMeas table |
| 1.3.6.1.4.1.20044.32.3.2.40.1.1 | Columnpm1004vMesrtxpwrMeasIndex | read-only | current | Index definition for the pm1004vMesrtxpwrMeas table |
| 1.3.6.1.4.1.20044.32.3.2.40.1.2 | Columnpm1004vMesrtxpwrMeasPortn | read-only | current | Client SFP Tx Power :This OID gives the transmit power value of the SFP plugged into port, read from the DDM (Digital Diagnostic Monitoring) (Power = 10*log(AV… |
| 1.3.6.1.4.1.20044.32.3.2.48 | Tablepm1004vMesrrxpwrMeasTable | not-accessible | current | List of pm1004vMesrrxpwrMeas Article |
| 1.3.6.1.4.1.20044.32.3.2.48.1 | Rowpm1004vMesrrxpwrMeasEntry | not-accessible | current | Row definition for the pm1004vMesrrxpwrMeas table |
| 1.3.6.1.4.1.20044.32.3.2.48.1.1 | Columnpm1004vMesrrxpwrMeasIndex | read-only | current | Index definition for the pm1004vMesrrxpwrMeas table |
| 1.3.6.1.4.1.20044.32.3.2.48.1.2 | Columnpm1004vMesrrxpwrMeasPortn | read-only | current | Client SFP Rx Power :This OID gives the receive power value of the SFP plugged into port, read in the DDM (Digital Diagnostic Monitoring) (Power = 10*log(AV)-4… |
| 1.3.6.1.4.1.20044.32.3.3 | Nodepm1004vMesrLine | |||
| 1.3.6.1.4.1.20044.32.3.3.208 | Tablepm1004vMesrxfp1LxModTempMeasTable | not-accessible | current | List of pm1004vMesrxfp1LxModTempMeas Article |
| 1.3.6.1.4.1.20044.32.3.3.208.1 | Rowpm1004vMesrxfp1LxModTempMeasEntry | not-accessible | current | Row definition for the pm1004vMesrxfp1LxModTempMeas table |
| 1.3.6.1.4.1.20044.32.3.3.208.1.1 | Columnpm1004vMesrxfp1LxModTempMeasIndex | read-only | current | Index definition for the pm1004vMesrxfp1LxModTempMeas table |
| 1.3.6.1.4.1.20044.32.3.3.208.1.2 | Columnpm1004vMesrxfp1LxModTempMeasPortn | read-only | current | Line Optical Module Temperature :This OID gives the temperature of the XFP or OTX plugged in line#n, read from the DDM (Digital Diagnostic Monitoring) (Tempera… |
| 1.3.6.1.4.1.20044.32.3.3.209 | Tablepm1004vMesrxfp1ReservedTable | not-accessible | deprecated | List of pm1004vMesrxfp1Reserved Article |
| 1.3.6.1.4.1.20044.32.3.3.209.1 | Rowpm1004vMesrxfp1ReservedEntry | not-accessible | deprecated | Row definition for the pm1004vMesrxfp1Reserved table |
| 1.3.6.1.4.1.20044.32.3.3.209.1.1 | Columnpm1004vMesrxfp1ReservedIndex | read-only | deprecated | Index definition for the pm1004vMesrxfp1Reserved table |
| 1.3.6.1.4.1.20044.32.3.3.209.1.2 | Columnpm1004vMesrxfp1ReservedPortn | read-only | deprecated | Not Used :Reserved |
| 1.3.6.1.4.1.20044.32.3.3.210 | Tablepm1004vMesrxfp1LoBiasCurrentMeasTable | not-accessible | current | List of pm1004vMesrxfp1LoBiasCurrentMeas Article |
| 1.3.6.1.4.1.20044.32.3.3.210.1 | Rowpm1004vMesrxfp1LoBiasCurrentMeasEntry | not-accessible | current | Row definition for the pm1004vMesrxfp1LoBiasCurrentMeas table |
| 1.3.6.1.4.1.20044.32.3.3.210.1.1 | Columnpm1004vMesrxfp1LoBiasCurrentMeasIndex | read-only | current | Index definition for the pm1004vMesrxfp1LoBiasCurrentMeas table |
| 1.3.6.1.4.1.20044.32.3.3.210.1.2 | Columnpm1004vMesrxfp1LoBiasCurrentMeasPortn | read-only | current | Line Optical Module Laser Bias :This OID gives the bias value of the XFP or OTX plugged in line #n, read from the DDM (Digital Diagnostic Monitoring) (Bias = A… |
| 1.3.6.1.4.1.20044.32.3.3.211 | Tablepm1004vMesrxfp1LoTxPowerMeasTable | not-accessible | current | List of pm1004vMesrxfp1LoTxPowerMeas Article |
| 1.3.6.1.4.1.20044.32.3.3.211.1 | Rowpm1004vMesrxfp1LoTxPowerMeasEntry | not-accessible | current | Row definition for the pm1004vMesrxfp1LoTxPowerMeas table |
| 1.3.6.1.4.1.20044.32.3.3.211.1.1 | Columnpm1004vMesrxfp1LoTxPowerMeasIndex | read-only | current | Index definition for the pm1004vMesrxfp1LoTxPowerMeas table |
| 1.3.6.1.4.1.20044.32.3.3.211.1.2 | Columnpm1004vMesrxfp1LoTxPowerMeasPortn | read-only | current | Line Optical Module Tx Power :This OID gives the transmit power value of the XFP or OTX plugged in line #n, read from the DDM (Digital Diagnostic Monitoring) (… |
| 1.3.6.1.4.1.20044.32.3.3.212 | Tablepm1004vMesrxfp1LiRxPowerMeasTable | not-accessible | current | List of pm1004vMesrxfp1LiRxPowerMeas Article |
| 1.3.6.1.4.1.20044.32.3.3.212.1 | Rowpm1004vMesrxfp1LiRxPowerMeasEntry | not-accessible | current | Row definition for the pm1004vMesrxfp1LiRxPowerMeas table |
| 1.3.6.1.4.1.20044.32.3.3.212.1.1 | Columnpm1004vMesrxfp1LiRxPowerMeasIndex | read-only | current | Index definition for the pm1004vMesrxfp1LiRxPowerMeas table |
| 1.3.6.1.4.1.20044.32.3.3.212.1.2 | Columnpm1004vMesrxfp1LiRxPowerMeasPortn | read-only | current | Line Optical Module Rx Power :This OID gives the receive power value of the XFP or OTX plugged in line #n, read from the DDM (Digital Diagnostic Monitoring) (P… |
| 1.3.6.1.4.1.20044.32.3.3.213 | Tablepm1004vMesrxfp1LxAux1MeasTable | not-accessible | deprecated | List of pm1004vMesrxfp1LxAux1Meas Article |
| 1.3.6.1.4.1.20044.32.3.3.213.1 | Rowpm1004vMesrxfp1LxAux1MeasEntry | not-accessible | deprecated | Row definition for the pm1004vMesrxfp1LxAux1Meas table |
| 1.3.6.1.4.1.20044.32.3.3.213.1.1 | Columnpm1004vMesrxfp1LxAux1MeasIndex | read-only | deprecated | Index definition for the pm1004vMesrxfp1LxAux1Meas table |
| 1.3.6.1.4.1.20044.32.3.3.213.1.2 | Columnpm1004vMesrxfp1LxAux1MeasPortn | read-only | deprecated | Not Used :This OID gives the receive power value read in the DDM (Digital Diagnostic Monitoring) of the XFP or OTX plugged in line #n (Unit = ?) |
| 1.3.6.1.4.1.20044.32.3.3.214 | Tablepm1004vMesrxfp1LxAux2MeasTable | not-accessible | deprecated | List of pm1004vMesrxfp1LxAux2Meas Article |
| 1.3.6.1.4.1.20044.32.3.3.214.1 | Rowpm1004vMesrxfp1LxAux2MeasEntry | not-accessible | deprecated | Row definition for the pm1004vMesrxfp1LxAux2Meas table |
| 1.3.6.1.4.1.20044.32.3.3.214.1.1 | Columnpm1004vMesrxfp1LxAux2MeasIndex | read-only | deprecated | Index definition for the pm1004vMesrxfp1LxAux2Meas table |
| 1.3.6.1.4.1.20044.32.3.3.214.1.2 | Columnpm1004vMesrxfp1LxAux2MeasPortn | read-only | deprecated | Not Used :This OID gives the receive power value read in the DDM (Digital Diagnostic Monitoring) of the XFP or OTX plugged in line #n (Unit = ?) |
| 1.3.6.1.4.1.20044.32.3.3.224 | Tablepm1004vMesrotx1AgingTable | not-accessible | current | List of pm1004vMesrotx1Aging Article |
| 1.3.6.1.4.1.20044.32.3.3.224.1 | Rowpm1004vMesrotx1AgingEntry | not-accessible | current | Row definition for the pm1004vMesrotx1Aging table |
| 1.3.6.1.4.1.20044.32.3.3.224.1.1 | Columnpm1004vMesrotx1AgingIndex | read-only | current | Index definition for the pm1004vMesrotx1Aging table |
| 1.3.6.1.4.1.20044.32.3.3.224.1.2 | Columnpm1004vMesrotx1AgingPortn | read-only | current | Line OTX TLH Aging :This OID gives the aging of the Line OTX TLH, read from the DDM (Digital Diagnostic Monitoring) (Aging = AV) (Unit = %) <Help> This measure… |
| 1.3.6.1.4.1.20044.32.3.3.225 | Tablepm1004vMesrotx1LaserTemperatureTable | not-accessible | deprecated | List of pm1004vMesrotx1LaserTemperature Article |
| 1.3.6.1.4.1.20044.32.3.3.225.1 | Rowpm1004vMesrotx1LaserTemperatureEntry | not-accessible | deprecated | Row definition for the pm1004vMesrotx1LaserTemperature table |
| 1.3.6.1.4.1.20044.32.3.3.225.1.1 | Columnpm1004vMesrotx1LaserTemperatureIndex | read-only | deprecated | Index definition for the pm1004vMesrotx1LaserTemperature table |
| 1.3.6.1.4.1.20044.32.3.3.225.1.2 | Columnpm1004vMesrotx1LaserTemperaturePortn | read-only | deprecated | Line OTX TLH Laser Temperature :This OID gives the laser temperature of the Line OTX TLH, read from the DDM (Digital Diagnostic Monitoring) (Temperature = AV/2… |
| 1.3.6.1.4.1.20044.32.3.3.226 | Tablepm1004vMesrotx1FreqDeviationTable | not-accessible | current | List of pm1004vMesrotx1FreqDeviation Article |
| 1.3.6.1.4.1.20044.32.3.3.226.1 | Rowpm1004vMesrotx1FreqDeviationEntry | not-accessible | current | Row definition for the pm1004vMesrotx1FreqDeviation table |
| 1.3.6.1.4.1.20044.32.3.3.226.1.1 | Columnpm1004vMesrotx1FreqDeviationIndex | read-only | current | Index definition for the pm1004vMesrotx1FreqDeviation table |
| 1.3.6.1.4.1.20044.32.3.3.226.1.2 | Columnpm1004vMesrotx1FreqDeviationPortn | read-only | current | Line OTX TLH Frequency Deviation :This OID gives the frequency deviation of the Line OTX TLH, read from the DDM (Digital Diagnostic Monitoring) (Deviation = (A… |
| 1.3.6.1.4.1.20044.32.3.3.227 | Tablepm1004vMesrotx1LaserWvlengthTable | not-accessible | current | List of pm1004vMesrotx1LaserWvlength Article |
| 1.3.6.1.4.1.20044.32.3.3.227.1 | Rowpm1004vMesrotx1LaserWvlengthEntry | not-accessible | current | Row definition for the pm1004vMesrotx1LaserWvlength table |
| 1.3.6.1.4.1.20044.32.3.3.227.1.1 | Columnpm1004vMesrotx1LaserWvlengthIndex | read-only | current | Index definition for the pm1004vMesrotx1LaserWvlength table |
| 1.3.6.1.4.1.20044.32.3.3.227.1.2 | Columnpm1004vMesrotx1LaserWvlengthPortn | read-only | current | Line Optical Module Wavelength :This OID gives the laser wavelength of the Line OTX TLH, read from the DDM (Digital Diagnostic Monitoring) (Wavelength=29979245… |
| 1.3.6.1.4.1.20044.32.4 | Nodepm1004vcounters | |||
| 1.3.6.1.4.1.20044.32.4.1 | Nodepm1004vCntOther | |||
| 1.3.6.1.4.1.20044.32.4.2 | Nodepm1004vCntClient | |||
| 1.3.6.1.4.1.20044.32.4.3 | Nodepm1004vCntLine | |||
| 1.3.6.1.4.1.20044.32.4.3.152 | Tablepm1004vCntdfrmB1ErrCntTable | not-accessible | current | List of pm1004vCntdfrmB1ErrCnt Article |
| 1.3.6.1.4.1.20044.32.4.3.152.1 | Rowpm1004vCntdfrmB1ErrCntEntry | not-accessible | current | Row definition for the pm1004vCntdfrmB1ErrCnt table |
| 1.3.6.1.4.1.20044.32.4.3.152.1.1 | Columnpm1004vCntdfrmB1ErrCntIndex | read-only | current | Index definition for the pm1004vCntdfrmB1ErrCnt table |
| 1.3.6.1.4.1.20044.32.4.3.152.1.2 | Columnpm1004vCntdfrmB1ErrCntValuePortn | read-only | current | Line Input CRC Errors :This counter is incremented each time a B1 error is detected on the Deframer input stream. <Help> This counter gives the number of B1 er… |
| 1.3.6.1.4.1.20044.32.4.3.152.1.3 | Columnpm1004vCntdfrmB1ErrCntErrorPortn | read-only | current | Line Counter Error :This OID when set indicates the B1 error counter value is invalid on Port |
| 1.3.6.1.4.1.20044.32.4.3.152.1.4 | Columnpm1004vCntdfrmB1ErrCntOverloadPortn | read-only | current | Line Counter Overload :This OID when set indicates a B1 error counter overload on Port |
| 1.3.6.1.4.1.20044.32.4.3.153 | Tablepm1004vCntdfrmTimCntTable | not-accessible | current | List of pm1004vCntdfrmTimCnt Article |
| 1.3.6.1.4.1.20044.32.4.3.153.1 | Rowpm1004vCntdfrmTimCntEntry | not-accessible | current | Row definition for the pm1004vCntdfrmTimCnt table |
| 1.3.6.1.4.1.20044.32.4.3.153.1.1 | Columnpm1004vCntdfrmTimCntIndex | read-only | current | Index definition for the pm1004vCntdfrmTimCnt table |
| 1.3.6.1.4.1.20044.32.4.3.153.1.2 | Columnpm1004vCntdfrmTimCntValuePortn | read-only | current | Line Timer Counter :This is the timing counter dedicated to the downstream deframer counters. It is incremented every 125 us. |
| 1.3.6.1.4.1.20044.32.4.3.153.1.3 | Columnpm1004vCntdfrmTimCntErrorPortn | read-only | current | Line Counter Error :This OID when set indicates the deframer timer counter value is invalid on Port |
| 1.3.6.1.4.1.20044.32.4.3.153.1.4 | Columnpm1004vCntdfrmTimCntOverloadPortn | read-only | current | Line Counter Overload :This OID when set indicates a deframer timer counter overload on Port |
| 1.3.6.1.4.1.20044.32.4.259 | Scalarpm1004vCntCountersReset | read-write | current | Counters Reset:This OID resets and restarts all the counters |
| 1.3.6.1.4.1.20044.32.4.260 | Scalarpm1004vCntCountersStop | read-write | current | Counters stop:This OID stops all the counters |
| 1.3.6.1.4.1.20044.32.6 | Nodepm1004vcontrolsWrite | |||
| 1.3.6.1.4.1.20044.32.6.1 | Nodepm1004vCtrlOther | |||
| 1.3.6.1.4.1.20044.32.6.1.1 | Nodepm1004vCtrlconfMgnt1 | |||
| 1.3.6.1.4.1.20044.32.6.1.1.1 | Scalarpm1004vCtrlConf1Load1 | read-write | current | Load Configuration Tables Set Nb 1 :When set this OID enables loading from flash configuration1 into the PM. |
| 1.3.6.1.4.1.20044.32.6.1.1.2 | Scalarpm1004vCtrlConf2Load1 | read-write | current | Load Configuration Tables Set Nb 2 :When set this OID enables loading from flash configuration2 into the PM. |
| 1.3.6.1.4.1.20044.32.6.1.1.10 | Scalarpm1004vCtrlConf2Flash1 | read-write | current | Write Configuration Tables :This OID saves the current configuration of the PM as configuration2 in the flash. <Help> This control saves the customer configura… |
| 1.3.6.1.4.1.20044.32.6.1.1.14 | Scalarpm1004vCtrlConf2Clear1 | read-write | current | Clear Configuration Tables :This OID clears the configuration tables from configuration2 in the flash. <Help> This control restores the default configuration o… |
| 1.3.6.1.4.1.20044.32.6.1.4 | Nodepm1004vCtrlsynth4 | |||
| 1.3.6.1.4.1.20044.32.6.1.4.1 | Scalarpm1004vCtrlCorrelatOn | read-write | current | Enable Alarm Correlation :This OID enables the alarm correlation in the PM. |
| 1.3.6.1.4.1.20044.32.6.1.4.2 | Scalarpm1004vCtrlCorrelatOff | read-write | current | Disable Alarm Correlation :This OID disables the alarm correlation in the PM. |
| 1.3.6.1.4.1.20044.32.6.1.5 | Nodepm1004vCtrlswMgnt | |||
| 1.3.6.1.4.1.20044.32.6.1.5.2 | Scalarpm1004vCtrlColdReset | read-write | current | PM Cold Reset :This OID, when set, causes a cold reset of the PM. This reset is traffic affecting, and the configuration of PM is reloaded on start-up. <Help> … |
| 1.3.6.1.4.1.20044.32.6.1.5.3 | Scalarpm1004vCtrlWarmReset | read-write | current | PM Warm Reset :This OID, when set, causes a warm reset of the PM. This reset is not traffic affecting, and the configuration of PM remains unchanged. <Help> Th… |
| 1.3.6.1.4.1.20044.32.6.1.5.5 | Scalarpm1004vCtrlLoadSwBank1 | read-write | current | Set Software Nb 1 As Active :This OID, when set, loads the SW from bank1 into the PM. It must be followed by a reset. <Help> This controls selects the first SW… |
| 1.3.6.1.4.1.20044.32.6.1.5.6 | Scalarpm1004vCtrlLoadSwBank2 | read-write | current | Set Software Nb 2 As Active :This OID, when set, loads the SW from bank2 into the PM. It must be followed by a reset. <Help> This controls selects the second S… |
| 1.3.6.1.4.1.20044.32.6.1.6 | Nodepm1004vCtrlgwMgnt | |||
| 1.3.6.1.4.1.20044.32.6.1.6.1 | Scalarpm1004vCtrlCurrentGwReset | read-write | current | Active Gateware Reset :This OID, when set, resets the active gateware. It is traffic affecting. |
| 1.3.6.1.4.1.20044.32.6.1.6.5 | Scalarpm1004vCtrlLoadGwBank1 | read-write | current | Set Gateware Nb 1 As Active :This OID, when set, loads the GW from bank1 (Flash) into the PM. It is followed by an automatic gateware cold reset. <Help> This c… |
| 1.3.6.1.4.1.20044.32.6.1.6.6 | Scalarpm1004vCtrlLoadGwBank2 | read-write | current | Set Gateware Nb 2 As Active :This OID, when set, loads the GW from bank2 (Flash) into the PM. It is followed by an automatic gateware cold reset. |
| 1.3.6.1.4.1.20044.32.6.1.6.7 | Scalarpm1004vCtrlLoadGwBank3 | read-write | current | Set Gateware Nb 3 As Active :This OID, when set, loads the GW from bank3 (Flash) into the PM. It is followed by an automatic gateware cold reset. <Help> This c… |
| 1.3.6.1.4.1.20044.32.6.1.6.8 | Scalarpm1004vCtrlLoadGwBank4 | read-write | current | Set Gateware Nb 4 As Active :This OID, when set, loads the GW from bank4 (Flash) into the PM. It is followed by an automatic gateware cold reset. |
| 1.3.6.1.4.1.20044.32.6.1.192 | Nodepm1004vCtrlledTest | |||
| 1.3.6.1.4.1.20044.32.6.1.192.1 | Scalarpm1004vCtrlGreenLed | read-write | current | Green Leds Test :This OID switches on all the green Leds as a test feature. <Help> This control initiates a test leds turning all the LEDs to green |
| 1.3.6.1.4.1.20044.32.6.1.192.2 | Scalarpm1004vCtrlRedLed | read-write | current | Red Leds Test :This OID switches on all the red Leds as a test feature. <Help> This control initiates a test leds turning all the LEDs to red |
| 1.3.6.1.4.1.20044.32.6.1.192.3 | Scalarpm1004vCtrlLedOff | read-write | current | Leds Off :This OID switches off all the Leds as a test feature. <Help> This control initiates a test leds turning all the LEDs to OFF |
| 1.3.6.1.4.1.20044.32.6.1.193 | Nodepm1004vCtrlmoduleOosMode | |||
| 1.3.6.1.4.1.20044.32.6.1.193.1 | Scalarpm1004vCtrlModuleOosMode | read-write | current | PM Out Of Service :This OID sets the PM Out Of Service <Help> This control defines the service state of the complete module |
| 1.3.6.1.4.1.20044.32.6.1.197 | Nodepm1004vCtrlmaintenanceMode | |||
| 1.3.6.1.4.1.20044.32.6.1.197.1 | Scalarpm1004vCtrlMaintenanceMode | read-write | current | Module Maintenance Mode :This OID enables the maintenance mode on the PM. <Help> This control enables the maintenance mode on the PM. |
| 1.3.6.1.4.1.20044.32.6.2 | Nodepm1004vCtrlClient | |||
| 1.3.6.1.4.1.20044.32.6.2.16 | Tablepm1004vCtrlaccessLoopTable | not-accessible | current | List of pm1004vCtrlaccessLoop Article |
| 1.3.6.1.4.1.20044.32.6.2.16.1 | Rowpm1004vCtrlaccessLoopEntry | not-accessible | current | Row definition for the pm1004vCtrlaccessLoop table |
| 1.3.6.1.4.1.20044.32.6.2.16.1.1 | Columnpm1004vCtrlaccessLoopIndex | read-only | current | Index definition for the pm1004vCtrlaccessLoop table |
| 1.3.6.1.4.1.20044.32.6.2.16.1.2 | Columnpm1004vCtrlaccessLoopPortn | read-write | current | Client Facility Loopback :This OID operates a Client Facility Loopback, looping client input signal on the client output port. The loop is located on the clien… |
| 1.3.6.1.4.1.20044.32.6.2.18 | Tablepm1004vCtrlportOosModeTable | not-accessible | current | List of pm1004vCtrlportOosMode Article |
| 1.3.6.1.4.1.20044.32.6.2.18.1 | Rowpm1004vCtrlportOosModeEntry | not-accessible | current | Row definition for the pm1004vCtrlportOosMode table |
| 1.3.6.1.4.1.20044.32.6.2.18.1.1 | Columnpm1004vCtrlportOosModeIndex | read-only | current | Index definition for the pm1004vCtrlportOosMode table |
| 1.3.6.1.4.1.20044.32.6.2.18.1.2 | Columnpm1004vCtrlportOosModePortn | read-write | current | Client Out Of Service :This OID sets the Service state of the client port (In Service, Tx Out of Service, Rx Out of Service or Port (Rx and Tx) Out of Service)… |
| 1.3.6.1.4.1.20044.32.6.2.20 | Tablepm1004vCtrlsfpOffCtrlTable | not-accessible | current | List of pm1004vCtrlsfpOffCtrl Article |
| 1.3.6.1.4.1.20044.32.6.2.20.1 | Rowpm1004vCtrlsfpOffCtrlEntry | not-accessible | current | Row definition for the pm1004vCtrlsfpOffCtrl table |
| 1.3.6.1.4.1.20044.32.6.2.20.1.1 | Columnpm1004vCtrlsfpOffCtrlIndex | read-only | current | Index definition for the pm1004vCtrlsfpOffCtrl table |
| 1.3.6.1.4.1.20044.32.6.2.20.1.2 | Columnpm1004vCtrlsfpOffCtrlPortn | read-write | current | Client Signal Shutdown :This OID switches off the SFP. <Help> This control defines the laser state of the client transceiver |
| 1.3.6.1.4.1.20044.32.6.2.21 | Tablepm1004vCtrlcsfUpInsTable | not-accessible | current | List of pm1004vCtrlcsfUpIns Article |
| 1.3.6.1.4.1.20044.32.6.2.21.1 | Rowpm1004vCtrlcsfUpInsEntry | not-accessible | current | Row definition for the pm1004vCtrlcsfUpIns table |
| 1.3.6.1.4.1.20044.32.6.2.21.1.1 | Columnpm1004vCtrlcsfUpInsIndex | read-only | current | Index definition for the pm1004vCtrlcsfUpIns table |
| 1.3.6.1.4.1.20044.32.6.2.21.1.2 | Columnpm1004vCtrlcsfUpInsPortn | read-write | current | Client Signal Fail Insertion :This OID, when set, inserts a client signal fail in the upstream client Port. <Help> This control inserts a Client Signal Fail fo… |
| 1.3.6.1.4.1.20044.32.6.2.22 | Tablepm1004vCtrlcaisDwInsTable | not-accessible | current | List of pm1004vCtrlcaisDwIns Article |
| 1.3.6.1.4.1.20044.32.6.2.22.1 | Rowpm1004vCtrlcaisDwInsEntry | not-accessible | current | Row definition for the pm1004vCtrlcaisDwIns table |
| 1.3.6.1.4.1.20044.32.6.2.22.1.1 | Columnpm1004vCtrlcaisDwInsIndex | read-only | current | Index definition for the pm1004vCtrlcaisDwIns table |
| 1.3.6.1.4.1.20044.32.6.2.22.1.2 | Columnpm1004vCtrlcaisDwInsPortn | read-write | current | Client AIS Insertion :This OID, when set, inserts a client AIS on the downstream client Port. <Help> This control inserts a Client AIS for the client port |
| 1.3.6.1.4.1.20044.32.6.2.26 | Tablepm1004vCtrlclientAccessTermLoopTable | not-accessible | current | List of pm1004vCtrlclientAccessTermLoop Article |
| 1.3.6.1.4.1.20044.32.6.2.26.1 | Rowpm1004vCtrlclientAccessTermLoopEntry | not-accessible | current | Row definition for the pm1004vCtrlclientAccessTermLoop table |
| 1.3.6.1.4.1.20044.32.6.2.26.1.1 | Columnpm1004vCtrlclientAccessTermLoopIndex | read-only | current | Index definition for the pm1004vCtrlclientAccessTermLoop table |
| 1.3.6.1.4.1.20044.32.6.2.26.1.2 | Columnpm1004vCtrlclientAccessTermLoopPortn | read-write | current | Client Terminal Loopback :This OID operates a Client Terminal Loopback, looping client input signal on the client output port. The loop is located on the line … |
| 1.3.6.1.4.1.20044.32.6.2.43 | Tablepm1004vCtrlrxVideoProtocolTable | not-accessible | current | List of pm1004vCtrlrxVideoProtocol Article |
| 1.3.6.1.4.1.20044.32.6.2.43.1 | Rowpm1004vCtrlrxVideoProtocolEntry | not-accessible | current | Row definition for the pm1004vCtrlrxVideoProtocol table |
| 1.3.6.1.4.1.20044.32.6.2.43.1.1 | Columnpm1004vCtrlrxVideoProtocolIndex | read-only | current | Index definition for the pm1004vCtrlrxVideoProtocol table |
| 1.3.6.1.4.1.20044.32.6.2.43.1.2 | Columnpm1004vCtrlrxVideoProtocolPortn | read-write | current | Force DVB ASI On RX Side :This OID selects the DVB ASI protocol on the client port and disable the auto-sensing feature <Help> This control selects the DVB ASI… |
| 1.3.6.1.4.1.20044.32.6.2.128 | Tablepm1004vCtrladddropClientRxProtectTable | not-accessible | current | List of pm1004vCtrladddropClientRxProtect Article |
| 1.3.6.1.4.1.20044.32.6.2.128.1 | Rowpm1004vCtrladddropClientRxProtectEntry | not-accessible | current | Row definition for the pm1004vCtrladddropClientRxProtect table |
| 1.3.6.1.4.1.20044.32.6.2.128.1.1 | Columnpm1004vCtrladddropClientRxProtectIndex | read-only | current | Index definition for the pm1004vCtrladddropClientRxProtect table |
| 1.3.6.1.4.1.20044.32.6.2.128.1.2 | Columnpm1004vCtrladddropClientRxProtectPortn | read-write | current | Client Switch Mode :This bit selects the manual (1) or automatic (0) switch method <Help> This control defines the protection switch mode on the client interfa… |
| 1.3.6.1.4.1.20044.32.6.2.136 | Tablepm1004vCtrladddropTsClientModeTable | not-accessible | current | List of pm1004vCtrladddropTsClientMode Article |
| 1.3.6.1.4.1.20044.32.6.2.136.1 | Rowpm1004vCtrladddropTsClientModeEntry | not-accessible | current | Row definition for the pm1004vCtrladddropTsClientMode table |
| 1.3.6.1.4.1.20044.32.6.2.136.1.1 | Columnpm1004vCtrladddropTsClientModeIndex | read-only | current | Index definition for the pm1004vCtrladddropTsClientMode table |
| 1.3.6.1.4.1.20044.32.6.2.136.1.2 | Columnpm1004vCtrladddropTsClientModePortn | read-write | current | Client Mode :This OID selects the mode on the client <Help> This control defines the mode (Add/Drop or Split&Select) of the Client |
| 1.3.6.1.4.1.20044.32.6.3 | Nodepm1004vCtrlLine | |||
| 1.3.6.1.4.1.20044.32.6.3.64 | Nodepm1004vCtrlcommAccessLoop | |||
| 1.3.6.1.4.1.20044.32.6.3.64.1 | Scalarpm1004vCtrlCommAccessloop | read-write | deprecated | PM Full Access Loop Mode :This OID, when set, puts the module in common access loop back, looping the 10 Gb/s output signal on the 10 Gb/s input. |
| 1.3.6.1.4.1.20044.32.6.3.66 | Nodepm1004vCtrllineLoop | |||
| 1.3.6.1.4.1.20044.32.6.3.66.1 | Scalarpm1004vCtrlLineLoop | read-write | deprecated | PM Line Loop Mode :This OID, when set at '1' puts the module in line loopback mode, looping the received 10 Gb/s signal on the transmit 10 Gb/s output. The Ups… |
| 1.3.6.1.4.1.20044.32.6.3.73 | Nodepm1004vCtrlProtMgnt | |||
| 1.3.6.1.4.1.20044.32.6.3.73.1 | Scalarpm1004vCtrlLineNumber | read-write | current | Active Line Number : This OID sets the active line number |
| 1.3.6.1.4.1.20044.32.6.3.73.2 | Scalarpm1004vCtrlProtMode | read-write | current | Line Switch Mode (Auto Or Manual) :This bit selects the manual (1) or automatic (0) switch method <Help> This control defines the protection switch mode on the… |
| 1.3.6.1.4.1.20044.32.6.3.74 | Tablepm1004vCtrllineOosModeTable | not-accessible | current | List of pm1004vCtrllineOosMode Article |
| 1.3.6.1.4.1.20044.32.6.3.74.1 | Rowpm1004vCtrllineOosModeEntry | not-accessible | current | Row definition for the pm1004vCtrllineOosMode table |
| 1.3.6.1.4.1.20044.32.6.3.74.1.1 | Columnpm1004vCtrllineOosModeIndex | read-only | current | Index definition for the pm1004vCtrllineOosMode table |
| 1.3.6.1.4.1.20044.32.6.3.74.1.2 | Columnpm1004vCtrllineOosModePortn | read-write | current | Line Out Of Service (!Laser OFF!) :This OID sets the line port Out Of Service <Help> This control defines the service state of the line port |
| 1.3.6.1.4.1.20044.32.6.3.198 | Tablepm1004vCtrldccEnableTable | not-accessible | current | List of pm1004vCtrldccEnable Article |
| 1.3.6.1.4.1.20044.32.6.3.198.1 | Rowpm1004vCtrldccEnableEntry | not-accessible | current | Row definition for the pm1004vCtrldccEnable table |
| 1.3.6.1.4.1.20044.32.6.3.198.1.1 | Columnpm1004vCtrldccEnableIndex | read-only | current | Index definition for the pm1004vCtrldccEnable table |
| 1.3.6.1.4.1.20044.32.6.3.198.1.2 | Columnpm1004vCtrldccEnablePortn | read-write | current | DCC Enable : This OID enables the DCC mode on the PM <Help> This control enables the DCC mode on the PM |
| 1.3.6.1.4.1.20044.32.6.3.208 | Tablepm1004vCtrlxfpOnoffTable | not-accessible | current | List of pm1004vCtrlxfpOnoff Article |
| 1.3.6.1.4.1.20044.32.6.3.208.1 | Rowpm1004vCtrlxfpOnoffEntry | not-accessible | current | Row definition for the pm1004vCtrlxfpOnoff table |
| 1.3.6.1.4.1.20044.32.6.3.208.1.1 | Columnpm1004vCtrlxfpOnoffIndex | read-only | current | Index definition for the pm1004vCtrlxfpOnoff table |
| 1.3.6.1.4.1.20044.32.6.3.208.1.2 | Columnpm1004vCtrlxfpOnoffPortn | read-write | current | Line Optical Module Laser Shutdown :This OID switches off the XFP or the OTX <Help> This control defines the laser state of the line transceiver |
| 1.3.6.1.4.1.20044.32.6.3.209 | Tablepm1004vCtrlxfpLineLoopTable | not-accessible | current | List of pm1004vCtrlxfpLineLoop Article |
| 1.3.6.1.4.1.20044.32.6.3.209.1 | Rowpm1004vCtrlxfpLineLoopEntry | not-accessible | current | Row definition for the pm1004vCtrlxfpLineLoop table |
| 1.3.6.1.4.1.20044.32.6.3.209.1.1 | Columnpm1004vCtrlxfpLineLoopIndex | read-only | current | Index definition for the pm1004vCtrlxfpLineLoop table |
| 1.3.6.1.4.1.20044.32.6.3.209.1.2 | Columnpm1004vCtrlxfpLineLoopPortn | read-write | current | Line Facility Loopback :This OID operates a Line Facility Loopback, looping line input signal on the line output port. The loop is located on the line transcei… |
| 1.3.6.1.4.1.20044.32.6.3.210 | Tablepm1004vCtrlxfpXfiLoopTable | not-accessible | current | List of pm1004vCtrlxfpXfiLoop Article |
| 1.3.6.1.4.1.20044.32.6.3.210.1 | Rowpm1004vCtrlxfpXfiLoopEntry | not-accessible | current | Row definition for the pm1004vCtrlxfpXfiLoop table |
| 1.3.6.1.4.1.20044.32.6.3.210.1.1 | Columnpm1004vCtrlxfpXfiLoopIndex | read-only | current | Index definition for the pm1004vCtrlxfpXfiLoop table |
| 1.3.6.1.4.1.20044.32.6.3.210.1.2 | Columnpm1004vCtrlxfpXfiLoopPortn | read-write | current | Line Terminal Loopback :This OID operates a Line Terminal Loopback, looping line input signal on the line output port. The loop is located on all client transc… |
| 1.3.6.1.4.1.20044.32.7 | Nodepm1004vri | |||
| 1.3.6.1.4.1.20044.32.7.1 | Nodepm1004vriTable | |||
| 1.3.6.1.4.1.20044.32.7.1.1 | Tablepm1004vRinvSfpTable | not-accessible | current | List of the SFPs on the selected module |
| 1.3.6.1.4.1.20044.32.7.1.1.1 | Rowpm1004vRinvSfpEntry | not-accessible | current | Row definition for the SFP table |
| 1.3.6.1.4.1.20044.32.7.1.1.1.1 | Columnpm1004vRinvSfpIndex | read-only | current | Index for SFP table |
| 1.3.6.1.4.1.20044.32.7.1.1.1.2 | Columnpm1004vRinvsfp | read-only | current | Inventory for the SFP: This OID contains the inventory for the SFP |
| 1.3.6.1.4.1.20044.32.7.1.2 | Tablepm1004vRinvLineTable | not-accessible | current | List of the XFPs on the selected module |
| 1.3.6.1.4.1.20044.32.7.1.2.1 | Rowpm1004vRinvLineEntry | not-accessible | current | Row definition for the XFP table |
| 1.3.6.1.4.1.20044.32.7.1.2.1.1 | Columnpm1004vRinvLineIndex | read-only | current | Index for XFP table |
| 1.3.6.1.4.1.20044.32.7.1.2.1.2 | Columnpm1004vRinvxfpLine | read-only | current | Inventory for the XFP: This OID contains the inventory for the XFP |
| 1.3.6.1.4.1.20044.32.7.2 | Scalarpm1004vRinvReloadInventory | read-write | current | Reload the inventory: This OID triggers an inventory reload. |
| 1.3.6.1.4.1.20044.32.7.3 | Scalarpm1004vRinvHwPlatform | read-only | current | HW platform description: This OID contains the description of the Hardware platform. |
| 1.3.6.1.4.1.20044.32.7.4 | Scalarpm1004vRinvModulePlatform | read-only | current | Module platform description: This OID contains the description of the Module. |
| 1.3.6.1.4.1.20044.32.7.5 | Scalarpm1004vRinvSwPlatform | read-only | current | SW platform description: This OID contains the description of the Software platform. |
| 1.3.6.1.4.1.20044.32.7.6 | Scalarpm1004vRinvGwPlatform | read-only | current | GW platform desciption: This OID contains the description of the Gateware platform. |
| 1.3.6.1.4.1.20044.32.8 | Nodepm1004vdownload | |||
| 1.3.6.1.4.1.20044.32.8.1 | Nodepm1004vDwlOther | |||
| 1.3.6.1.4.1.20044.32.8.1.0 | Nodepm1004vDwlrestartProcess | |||
| 1.3.6.1.4.1.20044.32.8.1.0.1 | Scalarpm1004vDwlWarmRestartProcessed | read-only | current | Warm Restart :This OID indicates that the module last restart was a Warm RESTART |
| 1.3.6.1.4.1.20044.32.8.1.0.2 | Scalarpm1004vDwlColdRestartProcessed | read-only | current | Cold Restart :This OID indicates that the module last restart was a Cold RESTART |
| 1.3.6.1.4.1.20044.32.8.1.1 | Nodepm1004vDwlswBanksUsed | |||
| 1.3.6.1.4.1.20044.32.8.1.1.1 | Scalarpm1004vDwlSwBank1Used | read-only | current | SW bank 1 active :This OID indicates the module is working on SW bank 1 <Help> This status indicates if the SW bank 1 is active or standby |
| 1.3.6.1.4.1.20044.32.8.1.1.2 | Scalarpm1004vDwlSwBank2Used | read-only | current | SW bank 2 active :This OID indicates the module is working on SW bank 2 <Help> This status indicates if the SW bank 2 is active or standby |
| 1.3.6.1.4.1.20044.32.8.1.1.5 | Scalarpm1004vDwlSwBank1Notempty | read-only | current | SW bank 1 loaded :This OID indicates a software is loaded in SW bank 1 <Help> This status indicates if the SW bank 1 contains SW package |
| 1.3.6.1.4.1.20044.32.8.1.1.6 | Scalarpm1004vDwlSwBank2Notempty | read-only | current | SW bank 2 loaded :This OID indicates a software is loaded in SW bank 2 <Help> This status indicates if the SW bank 2 contains SW package |
| 1.3.6.1.4.1.20044.32.8.1.2 | Nodepm1004vDwlgwBanksUsed | |||
| 1.3.6.1.4.1.20044.32.8.1.2.1 | Scalarpm1004vDwlGwBank1Used | read-only | current | GW bank 1 active :This OID indicates the module is working on GW bank 1 <Help> This status indicates if the GW bank 1 is active or standby |
| 1.3.6.1.4.1.20044.32.8.1.2.2 | Scalarpm1004vDwlGwBank2Used | read-only | current | GW bank 2 active :This OID indicates the module is working on GW bank 2 |
| 1.3.6.1.4.1.20044.32.8.1.2.3 | Scalarpm1004vDwlGwBank3Used | read-only | current | GW bank 3 active :This OID indicates the module is working on GW bank 3 <Help> This status indicates if the GW bank 3 is active or standby |
| 1.3.6.1.4.1.20044.32.8.1.2.4 | Scalarpm1004vDwlGwBank4Used | read-only | current | GW bank 4 active :This OID indicates the module is working on GW bank 4 |
| 1.3.6.1.4.1.20044.32.8.1.2.5 | Scalarpm1004vDwlGwBank1Notempty | read-only | current | GW bank 1 loaded :This OID indicates a gateware is loaded in GW bank 1 <Help> This status indicates if the GW bank 1 contains GW package |
| 1.3.6.1.4.1.20044.32.8.1.2.6 | Scalarpm1004vDwlGwBank2Notempty | read-only | current | GW bank 2 loaded :This OID indicates a gateware is loaded in GW bank 2 |
| 1.3.6.1.4.1.20044.32.8.1.2.7 | Scalarpm1004vDwlGwBank3Notempty | read-only | current | GW bank 3 loaded :This OID indicates a gateware is loaded in GW bank 3 <Help> This status indicates if the GW bank 3 contains GW package |
| 1.3.6.1.4.1.20044.32.8.1.2.8 | Scalarpm1004vDwlGwBank4Notempty | read-only | current | GW bank 4 loaded :This OID indicates a gateware is loaded in GW bank 4 |
| 1.3.6.1.4.1.20044.32.8.2 | Nodepm1004vDwlClient | |||
| 1.3.6.1.4.1.20044.32.8.3 | Nodepm1004vDwlLine | |||
| 1.3.6.1.4.1.20044.32.9 | Nodepm1004vConfig | |||
| 1.3.6.1.4.1.20044.32.9.1 | Nodepm1004vCfgAccessCAisCsf | |||
| 1.3.6.1.4.1.20044.32.9.1.1 | Tablepm1004vCfgClientcaiscsfTable | not-accessible | current | List of Article |
| 1.3.6.1.4.1.20044.32.9.1.1.1 | Rowpm1004vCfgClientcaiscsfEntry | not-accessible | current | Row definition for the accessCAisCsf table |
| 1.3.6.1.4.1.20044.32.9.1.1.1.1 | Columnpm1004vCfgClientcaiscsfIndex | read-only | current | Index definition for the clientcaiscsf table |
| 1.3.6.1.4.1.20044.32.9.1.1.1.3 | Columnpm1004vCfgCAisModePortn | read-write | current | CAIS mode on Client Port :This register enables/disables port laser shutdown on CAIS insertion condition |
| 1.3.6.1.4.1.20044.32.9.1.1.1.9 | Columnpm1004vCfgUpAccessioAlmPortn | read-write | current | CSF contributors on Client Port :This register configures the contributors to upstream CSF insertion on the port. |
| 1.3.6.1.4.1.20044.32.9.1.1.1.10 | Columnpm1004vCfgUpMapperDeAlmPortn | read-write | current | CSF contributors on Client Port :This register configures the contributors to upstream CSF insertion on the port. |
| 1.3.6.1.4.1.20044.32.9.1.1.1.17 | Columnpm1004vCfgDownAccessioAlmPortn | read-write | current | CAIS contributors on Client Port :This register configures the contributors to downstream CAIS insertion on port. |
| 1.3.6.1.4.1.20044.32.9.1.1.1.18 | Columnpm1004vCfgDownMapperDeAlmPortn | read-write | current | CAIS contributors on Client Port :This register configures the contributors to downstream CAIS insertion on port. |
| 1.3.6.1.4.1.20044.32.9.1.1.1.19 | Columnpm1004vCfgDownDfrmAlmPortn | read-write | current | CAIS contributors on Client Port :This register configures the contributors to downstream CAIS insertion on port. |
| 1.3.6.1.4.1.20044.32.9.1.1.1.20 | Columnpm1004vCfgDownLineSyncAlarmsPortn | read-write | deprecated | CAIS contributors on Client Port :This register configures the contributors to downstream CAIS insertion on port. |
| 1.3.6.1.4.1.20044.32.9.2 | Nodepm1004vCfgStartup | |||
| 1.3.6.1.4.1.20044.32.9.2.1 | Tablepm1004vCfgClientStartupTable | not-accessible | current | List of Article |
| 1.3.6.1.4.1.20044.32.9.2.1.1 | Rowpm1004vCfgClientStartupEntry | not-accessible | current | Row definition for the startup table |
| 1.3.6.1.4.1.20044.32.9.2.1.1.1 | Columnpm1004vCfgClientStartupIndex | read-only | current | Index definition for the clientStartup table |
| 1.3.6.1.4.1.20044.32.9.2.1.1.3 | Columnpm1004vCfgSystConfPortPortn | read-write | current | Default Settings on Client Port :This register configures the default initialisation settings on the port. |
| 1.3.6.1.4.1.20044.32.9.2.1.1.4 | Columnpm1004vCfgNetConfPortPortn | read-write | current | Default Protocol on Client Port :This register configures the default initialisation protocol on the port. |
| 1.3.6.1.4.1.20044.32.9.2.1.1.5 | Columnpm1004vCfgAdddropConfPortPortn | read-write | deprecated | Default Add&Drop mode on Client Port :This register configures the default Add&Drop mode on the port. |
| 1.3.6.1.4.1.20044.32.9.2.2 | Nodepm1004vtablelineStartup | |||
| 1.3.6.1.4.1.20044.32.9.2.2.2 | Scalarpm1004vCfgsystConfLine1 | read-write | current | Default Settings on Line 1 :This register configures the default initialisation settings on Line port 1. |
| 1.3.6.1.4.1.20044.32.9.2.2.5 | Scalarpm1004vCfglineOptions1 | read-write | current | Default Options on Active Line Port :This register configures the default options on the active line port |
| 1.3.6.1.4.1.20044.32.9.2.2.6 | Scalarpm1004vCfgsystConfLine2 | read-write | current | Default Settings on Line 2 :This register configures the default initialisation settings on Line port 2. |
| 1.3.6.1.4.1.20044.32.9.2.2.7 | Scalarpm1004vCfglineSelection | read-write | current | Default Settings of active line :This register configures the start up active line. |
| 1.3.6.1.4.1.20044.32.9.2.2.9 | Scalarpm1004vCfglineOptions2 | read-write | current | Default Options on Active Line Port :This register configures the default options on the active line port |
| 1.3.6.1.4.1.20044.32.9.2.3 | Tablepm1004vCfgXfpTable | not-accessible | current | List of Article |
| 1.3.6.1.4.1.20044.32.9.2.3.1 | Rowpm1004vCfgXfpEntry | not-accessible | current | Row definition for the startup table |
| 1.3.6.1.4.1.20044.32.9.2.3.1.1 | Columnpm1004vCfgXfpIndex | read-only | current | Index definition for the xfp table |
| 1.3.6.1.4.1.20044.32.9.2.3.1.3 | Columnpm1004vCfgSystConfXfpPortn | read-write | current | Default settings on XFP Port :This register configures the default initialisation settings on XFP port. |
| 1.3.6.1.4.1.20044.32.9.2.3.1.4 | Columnpm1004vCfgDataRateConfXfpPortn | read-write | deprecated | : |
| 1.3.6.1.4.1.20044.32.9.3 | Nodepm1004vCfgLabels | |||
| 1.3.6.1.4.1.20044.32.9.3.1 | Tablepm1004vCfgLabelclientTable | not-accessible | current | List of Article |
| 1.3.6.1.4.1.20044.32.9.3.1.1 | Rowpm1004vCfgLabelclientEntry | not-accessible | current | Row definition for the labels table |
| 1.3.6.1.4.1.20044.32.9.3.1.1.1 | Columnpm1004vCfgLabelclientIndex | read-only | current | Index definition for the labelclient table |
| 1.3.6.1.4.1.20044.32.9.3.1.1.3 | Columnpm1004vCfgLabelclientPortn | read-write | current | Default settings on the label of the Ports :These registers configures the default initialisation settings of the labels of the ports. |
| 1.3.6.1.4.1.20044.32.9.3.2 | Tablepm1004vCfgLabellineTable | not-accessible | current | List of Article |
| 1.3.6.1.4.1.20044.32.9.3.2.1 | Rowpm1004vCfgLabellineEntry | not-accessible | current | Row definition for the labels table |
| 1.3.6.1.4.1.20044.32.9.3.2.1.1 | Columnpm1004vCfgLabellineIndex | read-only | current | Index definition for the labelline table |
| 1.3.6.1.4.1.20044.32.9.3.2.1.3 | Columnpm1004vCfgLabellinePortn | read-write | current | Default settings on the label of the lines :These registers configures the default initialisation settings of the labels of the lines. |
| 1.3.6.1.4.1.20044.32.9.4 | Nodepm1004vCfgStartupthresholds | |||
| 1.3.6.1.4.1.20044.32.9.4.1 | Tablepm1004vCfgClientStartupThreshTable | not-accessible | current | List of Article |
| 1.3.6.1.4.1.20044.32.9.4.1.1 | Rowpm1004vCfgClientStartupThreshEntry | not-accessible | current | Row definition for the startupthresholds table |
| 1.3.6.1.4.1.20044.32.9.4.1.1.1 | Columnpm1004vCfgClientStartupThreshIndex | read-only | current | Index definition for the clientStartupThresh table |
| 1.3.6.1.4.1.20044.32.9.4.1.1.15 | Columnpm1004vCfgClientThreshtxpowhighPortn | read-write | current | Default Setting on Tx Power high threshold :This register configures the default initialisation of the high threshold of the Transmit power on the port. |
| 1.3.6.1.4.1.20044.32.9.4.1.1.16 | Columnpm1004vCfgClientThreshtxpowlowPortn | read-write | current | Default Setting on Tx Power low threshold :This register configures the default initialisation of the low threshold of the Transmit power on the port. |
| 1.3.6.1.4.1.20044.32.9.4.1.1.19 | Columnpm1004vCfgClientThreshrxpowhighPortn | read-write | current | Default Setting on Rx Power high threshold :This register configures the default initialisation of the high threshold of the received power on the port. |
| 1.3.6.1.4.1.20044.32.9.4.1.1.20 | Columnpm1004vCfgClientThreshrxpowlowPortn | read-write | current | Default Setting on Rx Power low threshold :This register configures the default initialisation of the low threshold of the received power on the port. |
| 1.3.6.1.4.1.20044.32.9.4.2 | Tablepm1004vCfgLineStartupThreshTable | not-accessible | current | List of Article |
| 1.3.6.1.4.1.20044.32.9.4.2.1 | Rowpm1004vCfgLineStartupThreshEntry | not-accessible | current | Row definition for the startupthresholds table |
| 1.3.6.1.4.1.20044.32.9.4.2.1.1 | Columnpm1004vCfgLineStartupThreshIndex | read-only | current | Index definition for the lineStartupThresh table |
| 1.3.6.1.4.1.20044.32.9.4.2.1.15 | Columnpm1004vCfgLineThreshtxpowhighPortn | read-write | current | Default Setting on Tx Power high threshold :This register configures the default initialisation of the high threshold of the Transmit power on the line. |
| 1.3.6.1.4.1.20044.32.9.4.2.1.16 | Columnpm1004vCfgLineThreshtxpowlowPortn | read-write | current | Default Setting on Tx Power low threshold :This register configures the default initialisation of the low threshold of the Transmit power on the line. |
| 1.3.6.1.4.1.20044.32.9.4.2.1.19 | Columnpm1004vCfgLineThreshrxpowhighPortn | read-write | current | Default Setting on Rx Power high threshold :This register configures the default initialisation of the high threshold of the received power on the line. |
| 1.3.6.1.4.1.20044.32.9.4.2.1.20 | Columnpm1004vCfgLineThreshrxpowlowPortn | read-write | current | Default Setting on Rx Power low threshold :This register configures the default initialisation of the low threshold of the received power on the line. |
| 1.3.6.1.4.1.20044.32.9.5 | Nodepm1004vCfgStartuptlh | |||
| 1.3.6.1.4.1.20044.32.9.5.1 | Tablepm1004vCfgOtxtlhTable | not-accessible | current | List of Article |
| 1.3.6.1.4.1.20044.32.9.5.1.1 | Rowpm1004vCfgOtxtlhEntry | not-accessible | current | Row definition for the startuptlh table |
| 1.3.6.1.4.1.20044.32.9.5.1.1.1 | Columnpm1004vCfgOtxtlhIndex | read-only | current | Index definition for the otxtlh table |
| 1.3.6.1.4.1.20044.32.9.5.1.1.3 | Columnpm1004vCfgNuPortn | read-write | deprecated | : |
| 1.3.6.1.4.1.20044.32.9.5.1.1.4 | Columnpm1004vCfgLineDitherRatePortn | read-write | current | Default Line OTX TLH FM amplitude :This register configures the start-up width of the frequency modulation of the Line OTX TLH |
| 1.3.6.1.4.1.20044.32.9.5.1.1.5 | Columnpm1004vCfgLineDitherFhzPortn | read-write | current | Default Line OTX TLH FM frequency :This register configures the start-up frequency of the frequency modulation of the Line OTX TLH |
| 1.3.6.1.4.1.20044.32.9.5.1.1.6 | Columnpm1004vCfgLinePwrLaserPortn | read-write | current | Defaut Line OTX TLH output Power :This register configures the start-up output power of the Line OTX TLH (Unit = dBm) |
| 1.3.6.1.4.1.20044.32.9.5.1.1.7 | Columnpm1004vCfgLineFCurrentPortn | read-write | current | Default Line OTX TLH Channel :This register configures the start-up laser channel of the Line OTX TLH |
| 1.3.6.1.4.1.20044.32.9.5.1.1.8 | Columnpm1004vCfgLineGridCurrentPortn | read-write | current | Default Line OTX TLH Grid :This register configures the start-up laser grid of the Line OTX TLH |
| 1.3.6.1.4.1.20044.32.9.5.1.1.9 | Columnpm1004vCfgFPortn | read-write | current | Default Line OTX TLH lowest Freq :This register configures the start-up lowest frequency supported on the Line OTX TLH |
| 1.3.6.1.4.1.20044.32.9.5.1.1.10 | Columnpm1004vCfgReservedPortn | read-write | deprecated | : |
| 1.3.6.1.4.1.20044.32.9.5.1.1.11 | Columnpm1004vCfgLinePhotodiodeModePortn | read-write | current | Default Line OTX TLH APD mode :This register configures the start-up APD mode of the Line OTX TLH |
| 1.3.6.1.4.1.20044.32.9.5.1.1.12 | Columnpm1004vCfgLinePhotodiodeValuePortn | read-write | current | Default Line OTX TLH APD atten. :This register configures the start-up APD attenuation on the Line OTX TLH |
| 1.3.6.1.4.1.20044.32.9.6 | Nodepm1004vCfgStartuptablefive | |||
| 1.3.6.1.4.1.20044.32.9.6.1 | Tablepm1004vCfgOtxtlhcapabilitiesTable | not-accessible | current | List of Article |
| 1.3.6.1.4.1.20044.32.9.6.1.1 | Rowpm1004vCfgOtxtlhcapabilitiesEntry | not-accessible | current | Row definition for the startuptablefive table |
| 1.3.6.1.4.1.20044.32.9.6.1.1.1 | Columnpm1004vCfgOtxtlhcapabilitiesIndex | read-only | current | Index definition for the otxtlhcapabilities table |
| 1.3.6.1.4.1.20044.32.9.6.1.1.3 | Columnpm1004vCfgComponentTypePortn | read-only | current | Component parameters :This OID defines the component parameters |
| 1.3.6.1.4.1.20044.32.9.6.1.1.4 | Columnpm1004vCfgMiscellaneousPortn | read-only | current | Miscellaneous default settings :This OID defines the miscellaneous parameters |
| 1.3.6.1.4.1.20044.32.9.6.1.1.5 | Columnpm1004vCfgFirstChannelPortn | read-only | current | Number of the first channel of the component :This OID defines the first channel number of the PM |
| 1.3.6.1.4.1.20044.32.9.6.1.1.6 | Columnpm1004vCfgLastChannelPortn | read-only | current | Number of the last channel of the component :This OID defines the last channel number of the PM |
| 1.3.6.1.4.1.20044.32.9.6.1.1.7 | Columnpm1004vCfgGridPortn | read-only | current | Grid value of the component :This OID defines the grid of the PM |
| 1.3.6.1.4.1.20044.32.9.257 | Scalarpm1004vCfgWriteConfiguration | read-write | current | Write configuration to module:This OID writes the complete configuration to the module |
| 1.3.6.1.4.1.20044.32.10 | Nodepm1004vtraps | |||
| 1.3.6.1.4.1.20044.32.10.2 | Scalarpm1004vtrapPortNumber | read-only | current | Last port which generates a trap |
| 1.3.6.1.4.1.20044.32.10.3 | Scalarpm1004vtrapLineNumber | read-only | current | Last Line which generates a trap |
| 1.3.6.1.4.1.20044.32.10.4 | Scalarpm1004vtrapBoardNumber | read-only | current | Last module which generates a trap |
| 1.3.6.1.4.1.20044.32.10.30 | Notificationpm1004vLineTrapNotUrgentGoesOn | current | Not urgent Line default is activated | |
| 1.3.6.1.4.1.20044.32.10.31 | Notificationpm1004vLineTrapNotUrgentGoesOff | current | Not urgent Line default disappeared | |
| 1.3.6.1.4.1.20044.32.10.32 | Notificationpm1004vLineTrapUrgentGoesOn | current | Urgent Line default is activated | |
| 1.3.6.1.4.1.20044.32.10.33 | Notificationpm1004vLineTrapUrgentGoesOff | current | Urgent Line default disappeared | |
| 1.3.6.1.4.1.20044.32.10.34 | Notificationpm1004vLineTrapCritGoesOn | current | Critical Line default is activated | |
| 1.3.6.1.4.1.20044.32.10.35 | Notificationpm1004vLineTrapCritGoesOff | current | Critical Line default disappeared | |
| 1.3.6.1.4.1.20044.32.10.40 | Notificationpm1004vClientTrapNotUrgentGoesOn | current | Not urgent client default is activated | |
| 1.3.6.1.4.1.20044.32.10.41 | Notificationpm1004vClientTrapNotUrgentGoesOff | current | Not urgent client default disappeared | |
| 1.3.6.1.4.1.20044.32.10.42 | Notificationpm1004vClientTrapUrgentGoesOn | current | Urgent client default is activated | |
| 1.3.6.1.4.1.20044.32.10.43 | Notificationpm1004vClientTrapUrgentGoesOff | current | Urgent client default disappeared | |
| 1.3.6.1.4.1.20044.32.10.44 | Notificationpm1004vClientTrapCritGoesOn | current | Critical client default is activated | |
| 1.3.6.1.4.1.20044.32.10.45 | Notificationpm1004vClientTrapCritGoesOff | current | Critical client default disappeared | |
| 1.3.6.1.4.1.20044.32.10.50 | Notificationpm1004vPowerTrapUrgentGoesOn | current | Urgent power supply default is activated | |
| 1.3.6.1.4.1.20044.32.10.51 | Notificationpm1004vPowerTrapUrgentGoesOff | current | Urgent power supply default disappeared | |
| 1.3.6.1.4.1.20044.32.11 | Nodepm1004vMonitoring | |||
| 1.3.6.1.4.1.20044.32.11.1 | Nodepm1004vMonOther | |||
| 1.3.6.1.4.1.20044.32.11.1.3 | Nodepm1004vMonRmon | |||
| 1.3.6.1.4.1.20044.32.11.1.3.359 | Scalarpm1004vMonCountersReset | read-write | current | RMON Counters Reset:This OID resets and restarts all the RMON counters |
| 1.3.6.1.4.1.20044.32.11.1.3.360 | Scalarpm1004vMonCountersStop | read-write | current | RMON Counters stop:This OID stops all the RMON counters |
| 1.3.6.1.4.1.20044.32.11.2 | Nodepm1004vMonClient | |||
| 1.3.6.1.4.1.20044.32.11.2.4 | Nodepm1004vMonClientRmonCounter | |||
| 1.3.6.1.4.1.20044.32.11.2.4.16 | Tablepm1004vMonupRmonByteCntTable | not-accessible | current | List of pm1004vMonupRmonByteCnt Article |
| 1.3.6.1.4.1.20044.32.11.2.4.16.1 | Rowpm1004vMonupRmonByteCntEntry | not-accessible | current | Row definition for the pm1004vMonupRmonByteCnt table |
| 1.3.6.1.4.1.20044.32.11.2.4.16.1.1 | Columnpm1004vMonupRmonByteCntIndex | read-only | current | Index definition for the pm1004vMonupRmonByteCnt table |
| 1.3.6.1.4.1.20044.32.11.2.4.16.1.2 | Columnpm1004vMonupRmonByteCntValuePortn | read-only | current | Client Input Bytes :This counter is increased each time a data byte is received on the client port <Help> This counter gives the number of bytes received on th… |
| 1.3.6.1.4.1.20044.32.11.2.4.16.1.3 | Columnpm1004vMonupRmonByteCntErrorPortn | read-only | current | Bytes Counter Error :This OID when set indicates the Bytes counter value is invalid on clinet port |
| 1.3.6.1.4.1.20044.32.11.2.4.16.1.4 | Columnpm1004vMonupRmonByteCntOverloadPortn | read-only | current | Bytes Counter Overload :This OID when set indicates a Bytes counter overload on client port |
| 1.3.6.1.4.1.20044.32.11.2.4.24 | Tablepm1004vMonupRmonCrcErrorCntTable | not-accessible | current | List of pm1004vMonupRmonCrcErrorCnt Article |
| 1.3.6.1.4.1.20044.32.11.2.4.24.1 | Rowpm1004vMonupRmonCrcErrorCntEntry | not-accessible | current | Row definition for the pm1004vMonupRmonCrcErrorCnt table |
| 1.3.6.1.4.1.20044.32.11.2.4.24.1.1 | Columnpm1004vMonupRmonCrcErrorCntIndex | read-only | current | Index definition for the pm1004vMonupRmonCrcErrorCnt table |
| 1.3.6.1.4.1.20044.32.11.2.4.24.1.2 | Columnpm1004vMonupRmonCrcErrorCntValuePortn | read-only | current | Client Input CRC Errors :This counter is increased each time a CRC error is detected on the client port <Help> This counter gives the number of CRC Errors rece… |
| 1.3.6.1.4.1.20044.32.11.2.4.24.1.3 | Columnpm1004vMonupRmonCrcErrorCntErrorPortn | read-only | current | CRC Errors Counter Error :This OID when set indicates the CRC Errors counter value is invalid on clinet port |
| 1.3.6.1.4.1.20044.32.11.2.4.24.1.4 | Columnpm1004vMonupRmonCrcErrorCntOverloadPortn | read-only | current | CRC Errors Counter Overload :This OID when set indicates a CRC Errors counter overload on client port |
| 1.3.6.1.4.1.20044.32.11.2.4.32 | Tablepm1004vMonupRmonPacketsCntTable | not-accessible | current | List of pm1004vMonupRmonPacketsCnt Article |
| 1.3.6.1.4.1.20044.32.11.2.4.32.1 | Rowpm1004vMonupRmonPacketsCntEntry | not-accessible | current | Row definition for the pm1004vMonupRmonPacketsCnt table |
| 1.3.6.1.4.1.20044.32.11.2.4.32.1.1 | Columnpm1004vMonupRmonPacketsCntIndex | read-only | current | Index definition for the pm1004vMonupRmonPacketsCnt table |
| 1.3.6.1.4.1.20044.32.11.2.4.32.1.2 | Columnpm1004vMonupRmonPacketsCntValuePortn | read-only | current | Client Input Packets :This counter is increased each time a packet is received on the client port <Help> This counter gives the number of packets received on t… |
| 1.3.6.1.4.1.20044.32.11.2.4.32.1.3 | Columnpm1004vMonupRmonPacketsCntErrorPortn | read-only | current | Packets Counter Error :This OID when set indicates the Packets counter value is invalid on clinet port |
| 1.3.6.1.4.1.20044.32.11.2.4.32.1.4 | Columnpm1004vMonupRmonPacketsCntOverloadPortn | read-only | current | Packets Counter Overload :This OID when set indicates a Packets counter overload on client port |
| 1.3.6.1.4.1.20044.32.11.2.4.40 | Tablepm1004vMonupRmonBroadcastCntTable | not-accessible | current | List of pm1004vMonupRmonBroadcastCnt Article |
| 1.3.6.1.4.1.20044.32.11.2.4.40.1 | Rowpm1004vMonupRmonBroadcastCntEntry | not-accessible | current | Row definition for the pm1004vMonupRmonBroadcastCnt table |
| 1.3.6.1.4.1.20044.32.11.2.4.40.1.1 | Columnpm1004vMonupRmonBroadcastCntIndex | read-only | current | Index definition for the pm1004vMonupRmonBroadcastCnt table |
| 1.3.6.1.4.1.20044.32.11.2.4.40.1.2 | Columnpm1004vMonupRmonBroadcastCntValuePortn | read-only | current | Client Input Broadcast Packets :This counter is increased each time a broadcast packet is received on the client port <Help> This counter gives the number of B… |
| 1.3.6.1.4.1.20044.32.11.2.4.40.1.3 | Columnpm1004vMonupRmonBroadcastCntErrorPortn | read-only | current | Broadcast Counter Error :This OID when set indicates the Broadcast counter value is invalid on clinet port |
| 1.3.6.1.4.1.20044.32.11.2.4.40.1.4 | Columnpm1004vMonupRmonBroadcastCntOverloadPortn | read-only | current | Broadcast Counter Overload :This OID when set indicates a Broadcast counter overload on client port |
| 1.3.6.1.4.1.20044.32.11.2.4.48 | Tablepm1004vMonupRmonMulticastCntTable | not-accessible | current | List of pm1004vMonupRmonMulticastCnt Article |
| 1.3.6.1.4.1.20044.32.11.2.4.48.1 | Rowpm1004vMonupRmonMulticastCntEntry | not-accessible | current | Row definition for the pm1004vMonupRmonMulticastCnt table |
| 1.3.6.1.4.1.20044.32.11.2.4.48.1.1 | Columnpm1004vMonupRmonMulticastCntIndex | read-only | current | Index definition for the pm1004vMonupRmonMulticastCnt table |
| 1.3.6.1.4.1.20044.32.11.2.4.48.1.2 | Columnpm1004vMonupRmonMulticastCntValuePortn | read-only | current | Client Input Multicast Packets :This counter is increased each time a Multicast packet is received on the client port <Help> This counter gives the number of M… |
| 1.3.6.1.4.1.20044.32.11.2.4.48.1.3 | Columnpm1004vMonupRmonMulticastCntErrorPortn | read-only | current | Multicast Counter Error :This OID when set indicates the Multicast counter value is invalid on clinet port |
| 1.3.6.1.4.1.20044.32.11.2.4.48.1.4 | Columnpm1004vMonupRmonMulticastCntOverloadPortn | read-only | current | Multicast Counter Overload :This OID when set indicates a Multicast counter overload on client port |
| 1.3.6.1.4.1.20044.32.11.2.4.208 | Tablepm1004vMonupLineRmonByteCntTable | not-accessible | current | List of pm1004vMonupLineRmonByteCnt Article |
| 1.3.6.1.4.1.20044.32.11.2.4.208.1 | Rowpm1004vMonupLineRmonByteCntEntry | not-accessible | current | Row definition for the pm1004vMonupLineRmonByteCnt table |
| 1.3.6.1.4.1.20044.32.11.2.4.208.1.1 | Columnpm1004vMonupLineRmonByteCntIndex | read-only | current | Index definition for the pm1004vMonupLineRmonByteCnt table |
| 1.3.6.1.4.1.20044.32.11.2.4.208.1.2 | Columnpm1004vMonupLineRmonByteCntValuePortn | read-only | current | Line Input Bytes :This counter is increased each time a data byte is received on the Line port <Help> This counter gives the number of bytes received on the Li… |
| 1.3.6.1.4.1.20044.32.11.2.4.208.1.3 | Columnpm1004vMonupLineRmonByteCntErrorPortn | read-only | current | Bytes Counter Error :This OID when set indicates the Bytes counter value is invalid on line port |
| 1.3.6.1.4.1.20044.32.11.2.4.208.1.4 | Columnpm1004vMonupLineRmonByteCntOverloadPortn | read-only | current | Bytes Counter Overload :This OID when set indicates a Bytes counter overload on line port |
| 1.3.6.1.4.1.20044.32.11.2.4.209 | Tablepm1004vMonupLineRmonCrcErrorCntTable | not-accessible | current | List of pm1004vMonupLineRmonCrcErrorCnt Article |
| 1.3.6.1.4.1.20044.32.11.2.4.209.1 | Rowpm1004vMonupLineRmonCrcErrorCntEntry | not-accessible | current | Row definition for the pm1004vMonupLineRmonCrcErrorCnt table |
| 1.3.6.1.4.1.20044.32.11.2.4.209.1.1 | Columnpm1004vMonupLineRmonCrcErrorCntIndex | read-only | current | Index definition for the pm1004vMonupLineRmonCrcErrorCnt table |
| 1.3.6.1.4.1.20044.32.11.2.4.209.1.2 | Columnpm1004vMonupLineRmonCrcErrorCntValuePortn | read-only | current | Line Input CRC Errors :This counter is increased each time a CRC error is detected on the Line port <Help> This counter gives the number of CRC Errors received… |
| 1.3.6.1.4.1.20044.32.11.2.4.209.1.3 | Columnpm1004vMonupLineRmonCrcErrorCntErrorPortn | read-only | current | CRC Errors Counter Error :This OID when set indicates the CRC Errors counter value is invalid on line port |
| 1.3.6.1.4.1.20044.32.11.2.4.209.1.4 | Columnpm1004vMonupLineRmonCrcErrorCntOverloadPortn | read-only | current | CRC Errors Counter Overload :This OID when set indicates a CRC Errors counter overload on line port |
| 1.3.6.1.4.1.20044.32.11.2.4.210 | Tablepm1004vMonupLineRmonPacketsCntTable | not-accessible | current | List of pm1004vMonupLineRmonPacketsCnt Article |
| 1.3.6.1.4.1.20044.32.11.2.4.210.1 | Rowpm1004vMonupLineRmonPacketsCntEntry | not-accessible | current | Row definition for the pm1004vMonupLineRmonPacketsCnt table |
| 1.3.6.1.4.1.20044.32.11.2.4.210.1.1 | Columnpm1004vMonupLineRmonPacketsCntIndex | read-only | current | Index definition for the pm1004vMonupLineRmonPacketsCnt table |
| 1.3.6.1.4.1.20044.32.11.2.4.210.1.2 | Columnpm1004vMonupLineRmonPacketsCntValuePortn | read-only | current | Line Input Packets :This counter is increased each time a packet is received on the Line port <Help> This counter gives the number of packets received on the L… |
| 1.3.6.1.4.1.20044.32.11.2.4.210.1.3 | Columnpm1004vMonupLineRmonPacketsCntErrorPortn | read-only | current | Packets Counter Error :This OID when set indicates the Packets counter value is invalid on client port |
| 1.3.6.1.4.1.20044.32.11.2.4.210.1.4 | Columnpm1004vMonupLineRmonPacketsCntOverloadPortn | read-only | current | Packets Counter Overload :This OID when set indicates a Packets counter overload on line port |
| 1.3.6.1.4.1.20044.32.11.3 | Nodepm1004vMonLine | |||
| 1.3.6.1.4.1.20044.32.11.3.4 | Nodepm1004vMonLineRmonCounter |
Type Definitions
| Name | Syntax | Status | Description |
|---|---|---|---|
| Pm1004vAdjustValue | INTEGER { otxadjustvalue0(0), otxadjustvalue1(1), otxadjustvalue2(2), otxadjustvalue3(3), otxadjustvalue4(4), otxadjustvalue5(5), otxadjustvalue6(6), otxadjustvalue7(7), otxadjustvalue8(8), otxadjustvalue9(9), otxadjustvalue10(10) } | current | Different values in Adjust mode on OTX-TLH on client and line ports |
| Pm1004vClientOosMode | INTEGER { clientportis(0), clienttxoos(1), clientrxoos(2), clientportoos(3) } | current | Mode for OOS on client ports |
| Pm1004vDccMode | INTEGER { dccNo(0), dcctermLine1(1), dcctermLine2(2), dcctermLines12(3), dccmaster(4), dccslaveLine12(7) } | current | Mode for DCC |
| Pm1004vModeAddDrop | INTEGER { singleSplitSelect(256) } | current | different mode for client |
| Pm1004vModeTimeSlot | INTEGER { singleSplitSelect(256) } | current | different mode for time slot |
| Pm1004vOtxChannel | INTEGER | current | Channel selection on OTX-TLH on client and line ports |
| Pm1004vOtxGrid | INTEGER { otxgrid200(200), otxgrid100(100), otxgrid50(50) } | current | Different grids on OTX-TLH on client and line ports |
| Pm1004vOtxMode | INTEGER { otx80mode(1), otx60mode(2), otxadjustmode(4) } | current | Different modes on OTX-TLH on client and line ports |
| Pm1004vProtectionStartUp | INTEGER { auto(2), manualX2Line2(0), manualX1Line1(1) } | current | protection for startup |
| Pm1004vProtectionTimeSlot | INTEGER { auto(0), manualX2Line2(257), manualX1Line1(513) } | current | protection for control |